WorldWideScience

Sample records for ground quality assurance

  1. Quality assurance

    International Nuclear Information System (INIS)

    Kunich, M.P.; Vieth, D.L.

    1989-01-01

    This paper provides a point/counterpoint view of a quality assurance director and a project manager. It presents numerous aspects of quality assurance requirements along with analyses as to the value of each

  2. Quality assurance

    International Nuclear Information System (INIS)

    Cante; Feger; Genevray; Hennion; Moneyron; Monneyron; Normand; Rastoin; Silberstein; Vaujour.

    1976-01-01

    The general principles of quality assurance and their applications within the French industrial and commercial regulations are presented. The conditions for the practical application of quality assurance to the different stages of the life of a nuclear power station (design, development, operation) are considered and a special mention is made of nuclear fuels and liquid sodium cooled reactors [fr

  3. Quality assurance

    International Nuclear Information System (INIS)

    1996-01-01

    The main efforts of Nuclear Regulatory Authority of the Slovak Republic (NRA SR) was focused on support of quality assurance programmes development at responsible organizations Bohunice V-1 and V-v and Mochovce NPPs and their inspection. Development of the level two documentation of a partial quality assurance programme for NPP operation continued at Mochovce NPP. Most of documentation has been submitted to NRA SR for comments and approval. NRA SR invited a mission of French experts to Mochovce NPP to review preparation and performance of internal audits that would be beneficial for improvement in this kind activities at the NPP. Bohunice NPP continued in development of a partial quality assurance programme for operation. The Quality Assurance Programme submitted to NRA SR for approval. Based on a request of Bohunice NPPs, NRA SR consulted the draft quality assurance programme developed by Siemens for stage of the 'Basic Design' of V-1 NPP upgrading. The programme had not been submitted for approval to NRA SR prior to completion of works by Siemens. Based on an internal audit that had been performed, corrective measures were proposed to meet requirements on review and approval of suppliers quality assurance programmes. Requirements related to the quality assurance at nuclear installations were prepared to be incorporated into principles of a act on peaceful use of nuclear power in Slovak Republic

  4. Quality assurance

    OpenAIRE

    Cauchi, Maurice A.M.

    1993-01-01

    The concept of quality assurance refers more specifically to the process of objectifying and clearly enunciating goals, and providing means of assessing the outcomes. In this article the author mentions four fundamental elements of quality assurance which should be applied in the medical profession in Malta. These elements should relate to professional performance, resource utilisation, risk management and patient satisfaction. The aim of the medical professionals in Malta is to provide the b...

  5. Quality assurance

    Energy Technology Data Exchange (ETDEWEB)

    Gillespie, B.M.; Gleckler, B.P.

    1995-06-01

    This section of the 1994 Hanford Site Environmental Report summarizes the quality assurance and quality control practices of Hanford Site environmental monitoring and surveillance programs. Samples are analyzed according to documented standard analytical procedures. This section discusses specific measures taken to ensure quality in project management, sample collection, and analytical results.

  6. Quality assurance

    International Nuclear Information System (INIS)

    Gillespie, B.M.; Gleckler, B.P.

    1995-01-01

    This section of the 1994 Hanford Site Environmental Report summarizes the quality assurance and quality control practices of Hanford Site environmental monitoring and surveillance programs. Samples are analyzed according to documented standard analytical procedures. This section discusses specific measures taken to ensure quality in project management, sample collection, and analytical results

  7. UMTRA project technical assistance contractor quality assurance implementation plan for surface and ground water

    International Nuclear Information System (INIS)

    1994-09-01

    The Uranium Mill Tailings Remedial Action (UMTRA) Project Technical Assistance Contractor (TAC) Quality Assurance Implementation Plan (QAIP) outlines the primary requirements for integrating quality functions for TAC technical activities applied to the surface and ground water phases of the UMTRA Project. The QAIP is subordinate to the latest issue of the UMTRA Project TAC Quality Assurance Program Plan (QAPP). The QAIP addresses technical aspects of the TAC UMTRA Project surface and ground water programs. The QAIP is authorized and approved by the TAC Project Manager and QA manager. The QA program is designed to use monitoring, audit, and surveillance functions as management tools to ensure that all Project organization activities are carried out in a manner that will protect public health and safety, promote the success of the UMTRA Project and meet or exceed contract requirements

  8. UMTRA project technical assistance contractor quality assurance implementation plan for surface and ground water, Revision 2

    International Nuclear Information System (INIS)

    1995-11-01

    This document contains the Technical Assistance Contractor (TAC) Quality Assurance Implementation Plan (QAIP) for the Uranium Mill Tailings Remedial Action (UMTRA) Project. The QAIP outlines the primary requirements for integrating quality functions for TAC technical activities applied to the surface and ground water phases of the UMTRA Project. The QA program is designed to use monitoring, audit, and surveillance activities as management tools to ensure that UMTRA Project activities are carried out in amanner to protect public health and safety, promote the success of the UMTRA Project, and meet or exceed contract requirements

  9. Quality assurance

    International Nuclear Information System (INIS)

    Hiller, G.H.

    1979-01-01

    This compendium intends to give fast bibliographic information and to fill the visible gap between documentation and general bibliographic information. The reader is given an outline of quality assurance and some examples of techniques from the relevant literature. The practical engineer, who is always short of time, is thus offered a quick survey and a fast deepening of his understanding by means of literature dealing specifically with his unresolved problems. The mansucript has been kept in tis original form in order to speed up tis publication. The RKW technical department limited itself to checking its contents and the adherence to the established information goals. (orig.) 891 RW/orig. 892 MB [de

  10. STEPP: A Grounded Model to Assure the Quality of Instructional Activities in e-Learning Environments

    Directory of Open Access Journals (Sweden)

    Hamdy AHMED ABDELAZIZ

    2013-07-01

    Full Text Available The present theoretical paper aims to develop a grounded model for designing instructional activities appropriate to e-learning and online learning environments. The suggested model is guided by learning principles of cognitivism, constructivism, and connectivism learning principles to help online learners constructing meaningful experiences and moving from knowledge acquisition to knowledge creation process. The proposed model consists of five dynamic and grounded domains that assure the quality of designing and using e-learning activities: Ø Social Domain; Ø Technological Domain; Ø Epistemological Domain; Ø Psychological domain; and Ø Pedagogical Domain. Each of these domains needs four types of presences to reflect the design and the application process of e-learning activities. These four presences are: Ø cognitive presence, Ø human presence, Ø psychological presence and Ø mental presence. Applying the proposed model (STEPP throughout all online and adaptive e-learning environments may improve the process of designing and developing e-learning activities to be used as mindtools for current and future learners.

  11. Introduction to quality assurance

    International Nuclear Information System (INIS)

    Kaden, W.

    1980-01-01

    In today's interpretation 'quality assurance' means 'good management'. Quality assurance has to cover all phases of a work, but all quality assurance measures must be adapted to the relevance and complexity of the actual task. Examples are given for the preparation of quality classes, the organization of quality assurance during design and manufacturing and for auditing. Finally, efficiency and limits of quality assurance systems are described. (orig.)

  12. Quality Assurance - Construction

    DEFF Research Database (Denmark)

    Gaarslev, Axel

    1996-01-01

    Gives contains three main chapters:1. Quality Assurance initiated by external demands2. Quality Assurance initiated by internal company goals3. Innovation strategies......Gives contains three main chapters:1. Quality Assurance initiated by external demands2. Quality Assurance initiated by internal company goals3. Innovation strategies...

  13. Data Quality Assurance Governance

    OpenAIRE

    Montserrat Gonzalez; Stephanie Suhr

    2016-01-01

    This deliverable describes the ELIXIR-EXCELERATE Quality Management Strategy, addressing EXCELERATE Ethics requirement no. 5 on Data Quality Assurance Governance. The strategy describes the essential procedures and practices within ELIXIR-EXCELERATE concerning planning of quality management, performing quality assurance and controlling quality. It also depicts the overall organisation of ELIXIR with emphasis on authority and specific responsibilities related to quality assurance.

  14. Quality assurance project plan for ground water monitoring activities managed by Westinghouse Hanford Company. Revision 3

    International Nuclear Information System (INIS)

    Stauffer, M.

    1995-11-01

    This quality assurance project plan (QAPP) applies specifically to the field activities and laboratory analysis performed for all RCRA groundwater projects conducted by Hanford Technical Services. This QAPP is generic in approach and shall be implemented in conjunction with the specific requirements of individual groundwater monitoring plans

  15. Computer software quality assurance

    International Nuclear Information System (INIS)

    Ives, K.A.

    1986-06-01

    The author defines some criteria for the evaluation of software quality assurance elements for applicability to the regulation of the nuclear industry. The author then analyses a number of software quality assurance (SQA) standards. The major extracted SQA elements are then discussed, and finally specific software quality assurance recommendations are made for the nuclear industry

  16. Multinational Quality Assurance

    Science.gov (United States)

    Kinser, Kevin

    2011-01-01

    Multinational colleges and universities pose numerous challenges to the traditional models of quality assurance that are designed to validate domestic higher education. When institutions cross international borders, at least two quality assurance protocols are involved. To guard against fraud and abuse, quality assurance in the host country is…

  17. Quality assurance of nuclear energy

    International Nuclear Information System (INIS)

    1994-12-01

    It consists of 14 chapters, which are outline of quality assurance of nuclear energy, standard of quality assurance, business quality assurance, design quality assurance, purchase quality assurance, production quality assurance, a test warranty operation warranty, maintenance warranty, manufacture of nuclear power fuel warranty, computer software warranty, research and development warranty and quality audit.

  18. The application of quality assurance

    International Nuclear Information System (INIS)

    Lovatt, G.B.

    1988-01-01

    The paper concerns the application of quality assurance to structures, systems and components for the design, construction and operation of nuclear power plant and fuel reprocessing plant. A description is given of:- the requirements for quality assurance, the establishment of quality assurance arrangements, quality assurance documents structure, and quality assurance manuals and programmes. Quality assurance procedures and auditing are also discussed. (U.K.)

  19. RAVEN Quality Assurance Activities

    Energy Technology Data Exchange (ETDEWEB)

    Cogliati, Joshua Joseph [Idaho National Lab. (INL), Idaho Falls, ID (United States)

    2015-09-01

    This report discusses the quality assurance activities needed to raise the Quality Level of Risk Analysis in a Virtual Environment (RAVEN) from Quality Level 3 to Quality Level 2. This report also describes the general RAVEN quality assurance activities. For improving the quality, reviews of code changes have been instituted, more parts of testing have been automated, and improved packaging has been created. For upgrading the quality level, requirements have been created and the workflow has been improved.

  20. Revitalizing quality assurance

    International Nuclear Information System (INIS)

    Hawkins, F.C.

    1998-01-01

    The image of someone inspecting or auditing often comes to mind when people hear the term quality assurance. Although partially correct, this image is not the complete picture. The person doing the inspecting or auditing is probably part of a traditional quality assurance organization, but that organization is only one aspect of a properly conceived and effectively implemented quality assurance system whose goal is improved facility safety and reliability. This paper introduces the underlying philosophies and basic concepts of the International Atomic Energy Agency's new quality assurance initiative that began in 1991 as part of a broad Agency-wide program to enhance nuclear safety. The first product of that initiative was publication in 1996 of a new Quality Assurance Code 50-C/SG-Q and fourteen related Safety Guides. This new suite of documents provide the technical and philosophical foundation upon which Member States can base their quality assurance programs. (author)

  1. Quality assurance in radiodiagnosis

    International Nuclear Information System (INIS)

    Ghilardi Netto, T.; Sao Paulo Univ., Ribeirao Preto

    1983-01-01

    The following topics are dealt with: 1) the importance of the application of a quality assurance program in radiodiagnosis, with its main consequences : improvement of imaging quality, reduction of the patient expossure rate, cost reduction and 2) how to introduce the quality assurance control in the radiodiagnostic area. (M.A.) [pt

  2. Laboratory quality assurance

    International Nuclear Information System (INIS)

    Delvin, W.L.

    1977-01-01

    The elements (principles) of quality assurance can be applied to the operation of the analytical chemistry laboratory to provide an effective tool for indicating the competence of the laboratory and for helping to upgrade competence if necessary. When used, those elements establish the planned and systematic actions necessary to provide adequate confidence in each analytical result reported by the laboratory (the definition of laboratory quality assurance). The elements, as used at the Hanford Engineering Development Laboratory (HEDL), are discussed and they are qualification of analysts, written methods, sample receiving and storage, quality control, audit, and documentation. To establish a laboratory quality assurance program, a laboratory QA program plan is prepared to specify how the elements are to be implemented into laboratory operation. Benefits that can be obtained from using laboratory quality assurance are given. Experience at HEDL has shown that laboratory quality assurance is not a burden, but it is a useful and valuable tool for the analytical chemistry laboratory

  3. Quality assurance program

    International Nuclear Information System (INIS)

    Brooks, G.L.

    The concept of levels of quality assurance as applied to CANDU-type nuclear power plant components, i.e. maintaining an appropriate cost/benefit ratio, is introduced. The design process itself has quality assurance features by virtue of multi-level review. (E.C.B.)

  4. Quality assurance. 6. ed.

    International Nuclear Information System (INIS)

    Masing, W.

    1979-01-01

    Brief introduction to the quality sector. After some explanations of the terms of quality, feature, and defect, the article discusses the planning of quality and testing, industrial metrology, the test risk, quality assurance, quality enhancement, quality cost, and organisational problems. (RW) [de

  5. Quality assurance of metabolomics.

    Science.gov (United States)

    Bouhifd, Mounir; Beger, Richard; Flynn, Thomas; Guo, Lining; Harris, Georgina; Hogberg, Helena; Kaddurah-Daouk, Rima; Kamp, Hennicke; Kleensang, Andre; Maertens, Alexandra; Odwin-DaCosta, Shelly; Pamies, David; Robertson, Donald; Smirnova, Lena; Sun, Jinchun; Zhao, Liang; Hartung, Thomas

    2015-01-01

    Metabolomics promises a holistic phenotypic characterization of biological responses to toxicants. This technology is based on advanced chemical analytical tools with reasonable throughput, including mass-spectroscopy and NMR. Quality assurance, however - from experimental design, sample preparation, metabolite identification, to bioinformatics data-mining - is urgently needed to assure both quality of metabolomics data and reproducibility of biological models. In contrast to microarray-based transcriptomics, where consensus on quality assurance and reporting standards has been fostered over the last two decades, quality assurance of metabolomics is only now emerging. Regulatory use in safety sciences, and even proper scientific use of these technologies, demand quality assurance. In an effort to promote this discussion, an expert workshop discussed the quality assurance needs of metabolomics. The goals for this workshop were 1) to consider the challenges associated with metabolomics as an emerging science, with an emphasis on its application in toxicology and 2) to identify the key issues to be addressed in order to establish and implement quality assurance procedures in metabolomics-based toxicology. Consensus has still to be achieved regarding best practices to make sure sound, useful, and relevant information is derived from these new tools.

  6. Software quality assurance handbook

    Energy Technology Data Exchange (ETDEWEB)

    1990-09-01

    There are two important reasons for Software Quality Assurance (SQA) at Allied-Signal Inc., Kansas City Division (KCD): First, the benefits from SQA make good business sense. Second, the Department of Energy has requested SQA. This handbook is one of the first steps in a plant-wide implementation of Software Quality Assurance at KCD. The handbook has two main purposes. The first is to provide information that you will need to perform software quality assurance activities. The second is to provide a common thread to unify the approach to SQA at KCD. 2 figs.

  7. Quality assurance in NDT

    International Nuclear Information System (INIS)

    Krishnamoorthy, K.

    2010-01-01

    The importance of Nondestructive Testing (NDT) as a Quality Control/Quality Assurance tool in the industrial domain cannot be over-emphasized. With the rapid advancement in research and technology, the NDT field is becoming larger and more sophisticated day by day. Innovative research in materials science and digital technology is paving the way for more and more new methods in NDT technology. Although the NDT technology has improved over the years, the basic 'human factor' underlying the success of the NDT field remains the same. There are two major factors that influence the 'Quality Assurance in NDT'. First, knowledgeable and skilled NDT Operators are the most important factor in assuring the reliable test results. Second, the Management oversight of the NDT operations plays a major role in assuring the overall quality of NDT. Management responsibilities include the implementation of a Quality Management System (QMS) that focuses on the NDT operations and apply all the elements of Quality Assurance relevant to NDT. Whether the NDT operations are performed in-house or by a contractor, periodic Management Self-assessments should include the following question: How can the Management assess and improve the 'Quality Assurance in NDT'? This paper attempts to answer the above question. Some practical examples are provided to illustrate the potential quality incidents that could lead to costly failures, and the role of NDT Operator and the Management in preventing such quality incidents. Also, some guidelines are provided on how the Management can apply the elements of Quality Assurance to NDT in order to assess and improve the 'Quality Assurance in NDT'. (author)

  8. Quality assurance and management

    International Nuclear Information System (INIS)

    Newcomb, W.E.

    1989-01-01

    This paper traces the evolution of the quality assurance program of an office of waste management development (OWTD). The program's needs and commitment are examined. The author reports on the role of program and technical managers in such a program

  9. Quality assurance in radiotherapy

    International Nuclear Information System (INIS)

    Groth, S.; Meghzifene, A.; Tatsuzaki, H.; Levin, V.; Izewska, J.

    2001-01-01

    Quality assurance in the management of a patient receiving radiation therapy and the role of the radiation oncologist and medical physicist in this process is described. The constraints on available personnel are recognised and the need for further education resources and IAEA activities in education for both groups described. IAEA activities in the clinical and dosimetric aspects and the resultant publications and education have contributed to a culture of quality assurance. (author)

  10. Ground-water-quality assessment of the Central Oklahoma aquifer, Oklahoma; hydrologic, water-quality, and quality-assurance data 1987-90

    Science.gov (United States)

    Ferree, D.M.; Christenson, S.C.; Rea, A.H.; Mesander, B.A.

    1992-01-01

    This report presents data collected from 202 wells between June 1987 and September 1990 as part of the Central Oklahoma aquifer pilot study of the National Water-Quality Assessment Program. The report describes the sampling networks, the sampling procedures, and the results of the ground-water quality and quality-assurance sample analyses. The data tables consist of information about the wells sampled and the results of the chemical analyses of ground water and quality-assurance sampling. Chemical analyses of ground-water samples in four sampling networks are presented: A geochemical network, a low-density survey bedrock network, a low-density survey alluvium and terrace deposits network, and a targeted urban network. The analyses generally included physical properties, major ions, nutrients, trace substances, radionuclides, and organic constituents. The chemical analyses of the ground-water samples are presented in five tables: (1) Physical properties and concentrations of major ions, nutrients, and trace substances; (2) concentrations of radionuclides and radioactivities; (3) carbon isotope ratios and delta values (d-values) of selected isotopes; (4) concentrations of organic constituents; and (5) organic constituents not reported in ground-water samples. The quality of the ground water sampled varied substantially. The sum of constituents (dissolved solids) concentrations ranged from 71 to 5,610 milligrams per liter, with 38 percent of the wells sampled exceeding the Secondary Maximum Contaminant Level of 500 milligrams per liter established under the Safe Drinking Water Act. Values of pH ranged from 5.7 to 9.2 units with 20 percent of the wells outside the Secondary Maximum Contaminant Level of 6.5 to 8.5 units. Nitrite plus nitrate concentrations ranged from less than 0.1 to 85 milligrams per liter with 8 percent of the wells exceeding the proposed Maximum Contaminant Level of 10 milligrams per liter. Concentrations of trace substances were highly variable

  11. Software quality assurance

    CERN Document Server

    Laporte, Claude Y

    2018-01-01

    This book introduces Software Quality Assurance (SQA) and provides an overview of standards used to implement SQA. It defines ways to assess the effectiveness of how one approaches software quality across key industry sectors such as telecommunications, transport, defense, and aerospace. * Includes supplementary website with an instructor's guide and solutions * Applies IEEE software standards as well as the Capability Maturity Model Integration for Development (CMMI) * Illustrates the application of software quality assurance practices through the use of practical examples, quotes from experts, and tips from the authors

  12. SGHWR - quality assurance documentation

    International Nuclear Information System (INIS)

    Garrard, R.S.; Caulfield, J.

    1976-01-01

    The quality assurance program for a modern power station such as an SGHWR type reactor plant must include a record of quality achievement. The case history record which is evidence of the actual quality of the plant and is a data bank of design, manufacture, and results of inspections and tests, is described. Documentation distribution, which keeps all key areas informed of plant item quality status, and the retrieval and storage of information, are briefly discussed. (U.K.)

  13. Nuclear fuel quality assurance

    International Nuclear Information System (INIS)

    1976-01-01

    Full text: Quality assurance is used extensively in the design, construction and operation of nuclear power plants. This methodology is applied to all activities affecting the quality of a nuclear power plant in order to obtain confidence that an item or a facility will perform satisfactorily in service. Although the achievement of quality is the responsibility of all parties participating in a nuclear power project, establishment and implementation of the quality assurance programme for the whole plant is a main responsibility of the plant owner. For the plant owner, the main concern is to achieve control over the quality of purchased products or services through contractual arrangements with the vendors. In the case of purchase of nuclear fuel, the application of quality assurance might be faced with several difficulties because of the lack of standardization in nuclear fuel and the proprietary information of the fuel manufacturers on fuel design specifications and fuel manufacturing procedures. The problems of quality assurance for purchase of nuclear fuel were discussed in detail during the seminar. Due to the lack of generally acceptable standards, the successful application of the quality assurance concept to the procurement of fuel depends on how much information can be provided by the fuel manufacturer to the utility which is purchasing fuel, and in what form and how early this information can be provided. The extent of information transfer is basically set out in the individual vendor-utility contracts, with some indirect influence from the requirements of regulatory bodies. Any conflict that exists appears to come from utilities which desire more extensive control over the product they are buying. There is a reluctance on the part of vendors to permit close insight of the purchasers into their design and manufacturing procedures, but there nevertheless seems to be an increasing trend towards release of more information to the purchasers. It appears that

  14. Chapter 8: Quality assurance

    International Nuclear Information System (INIS)

    2001-01-01

    The main efforts of Nuclear Regulatory Authority of the Slovak Republic (UJD) have been focused on inspection of quality assurance programmes of Slovak Power Stations, plc. and its daughter companies at Bohunice and Mochovce. Two quality assurance inspections in the area of periodical in service inspections (V-2 units) and tests of selected equipment (NPP V-2 units) and operation control (V-1 units) has been performed at NPPs Bohunice. One violation of decree on quality assurance of selected equipment has been found in the area of documentation archiving. The inspection concerning the implementation of quality assurance programme for operation of NPP Mochovce in the area of operation control has been performed focused on safety aspects of operation, operational procedures, control of operational events and feedback from operational experience. The results of this inspection were positive. Inspection of implementation of quality assurance programme for operation of radioactive waste repository (RU RAW) at the Mochovce location has been performed focused on receiving of containers, with radioactive wastes, containers handling, radiation monitoring, activities of documentation control and radiation protection at the repository site. No serious deficiencies have been found out. Also one inspection of experimental nuclear installations of VUJE Trnava at Jaslovske Bohunice site has been performed focused on procurement control, quality audits, documentation and quality records control when performing activities at experimental nuclear installations. The activity on development of internal quality assurance system continued. The implementation of this system will assure quality and effective fulfilment enlarged tasks of UJD with limited resources for its activity. The analyses of possible use of existing internal administrative control documentation as a basis for future quality system procedures was performed in co-operation with an external specialised organisation. The

  15. [Integrated quality assurance].

    Science.gov (United States)

    Bögel, K; Stöhr, K

    1994-07-01

    The definition of terms and connotation of "Quality", "Quality Assurance" and "Integration" lead to an analysis and understanding of inhibiting and fostering factors of the "Health Triad" of people, animals and environment. Although "Quality" is largely or ultimately determined by the consumer, there are considerable differences as this term is applied by (a) the individual consumer, (b) the dynamic producer defending or gaining markets, (c) those engaged in traditional product manufacturing, or (d) governments setting (minimum) requirements for the sake of free trade. "Quality Assurance" offers cooperation of partners all along the food chain from "pasture to table". The managerial process turned into a continuum of responsibility and agreement on processes and product characteristics. This overcomes the disadvantages of strategies stressing distinct defense barriers. In practice this philosophy of a predominant role of defence barriers proved largely partnership destructive, in that it permitted to shift responsibilities for failures and to claim administrative competence according to momentary situations and interests. "Integrated Quality Assurance" means mutual agreement of two or more partners along the food chain (e. g. feed producers, farmers, animal health industry, veterinarians and food processors) on product characteristics and production methods. It involves essential system elements including facilities, materials, manpower, information, transport, management etc. Different principles and procedures of quality assurance have been introduced in practice, including agriculture and food processing. These different approaches are not mutually exclusive but largely of complementary nature.(ABSTRACT TRUNCATED AT 250 WORDS)

  16. Quality assurance of radiopharmaceuticals

    International Nuclear Information System (INIS)

    Frier, M.; Hesslewood, S.R.

    1980-01-01

    A practical guide has been composed for all persons involved in the preparation and use of radiopharmaceuticals on methods used in quality assurance and their applications. These methods include the calibration of ionization chamber assay calibrators, the determination of radionuclide purity, radiochemical purity and chemical purity, particle size analysis and the measurement of pH. Quality assurance procedures are described for products not described in Compendial Monographs, or where the monograph exists, additional useful information is provided; such radiopharmaceuticals include technetium, indium-labelled and iodine-labelled products. (U.K.)

  17. Quality assurance in microbiology

    OpenAIRE

    Arora D

    2004-01-01

    Quality assurance (QA) is the total process whereby the quality of laboratory reports can be guaranteed. The term quality control covers that part of QA, which primarily concerns the control of errors in the performance of tests and verification of test results. All materials, equipment and procedures must be adequately controlled. Culture media must be tested for sterility and performance. Each laboratory must have standard operating procedures (SOPs). QA of pre-analytical, analytical and po...

  18. Measurement quality assurance

    International Nuclear Information System (INIS)

    Eisenhower, E.H.

    1988-01-01

    The quality of a radiation protection program can be no better than the quality of the measurements made to support it. In many cases, that quality is unknown and is merely implied on the basis of a calibration of a measuring instrument. If that calibration is inappropriate or is performed improperly, the measurement result will be inaccurate and misleading. Assurance of measurement quality can be achieved if appropriate procedures are followed, including periodic quality control actions that demonstrate adequate performance. Several national measurement quality assurance (MQA) programs are operational or under development in specific areas. They employ secondary standards laboratories that provide a high-quality link between the National Bureau of Standards and measurements made at the field use level. The procedures followed by these secondary laboratories to achieve MQA will be described, as well as plans for similar future programs. A growing general national interest in quality assurance, combined with strong specific motivations for MQA in the area of ionizing radiation, will provide continued demand for appropriate national programs. Such programs must, however, employ procedures that are cost effective and must be developed with participation by all affected parties

  19. Quality Assurance Program Description

    Energy Technology Data Exchange (ETDEWEB)

    Halford, Vaughn Edward [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Ryder, Ann Marie [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)

    2017-07-01

    Effective May 1, 2017, led by a new executive leadership team, Sandia began operating within a new organizational structure. National Technology and Engineering Solutions of Sandia (Sandia’s) Quality Assurance Program (QAP) was established to assign responsibilities and authorities, define workflow policies and requirements, and provide for the performance and assessment of work.

  20. Quality management and quality assurance

    International Nuclear Information System (INIS)

    Pieroni, N.

    1991-01-01

    The main common difficulties are presented found in the implementation of effective Quality Management and Quality Assurance Programmes, based on the recommendations of the IAEA International Nuclear Safety Advisory Group, the information collected by the IAEA experts participating in its meetings, and the results of the IAEA Operational Safety Review Team missions. The difficulties were identified in several areas. The most relevant root causes can be characterized as lack of understanding of quality principles and difficulty in implementation by the responsible management. The IAEA programme is described attempting to provide advice and support in the implementation of an effective quality programme through a number of activities including: preparation of practical guidelines, training programmes for management personnel, assistance in building up qualified manpower, and promoting the quest for excellence through the exchange of experience in the implementation of effective Quality Management and Quality Assurance Programmes in nuclear power plants with good performance records. (Z.S.)

  1. Power transformers quality assurance

    CERN Document Server

    Dasgupta, Indrajit

    2009-01-01

    About the Book: With the view to attain higher reliability in power system operation, the quality assurance in the field of distribution and power transformers has claimed growing attention. Besides new developments in the material technology and manufacturing processes of transformers, regular diagnostic testing and maintenance of any engineering product may be ascertained by ensuring: right selection of materials and components and their quality checks. application of correct manufacturing processes any systems engineering. the user`s awareness towards preventive maintenance. The

  2. Software Quality Assurance Metrics

    Science.gov (United States)

    McRae, Kalindra A.

    2004-01-01

    Software Quality Assurance (SQA) is a planned and systematic set of activities that ensures conformance of software life cycle processes and products conform to requirements, standards and procedures. In software development, software quality means meeting requirements and a degree of excellence and refinement of a project or product. Software Quality is a set of attributes of a software product by which its quality is described and evaluated. The set of attributes includes functionality, reliability, usability, efficiency, maintainability, and portability. Software Metrics help us understand the technical process that is used to develop a product. The process is measured to improve it and the product is measured to increase quality throughout the life cycle of software. Software Metrics are measurements of the quality of software. Software is measured to indicate the quality of the product, to assess the productivity of the people who produce the product, to assess the benefits derived from new software engineering methods and tools, to form a baseline for estimation, and to help justify requests for new tools or additional training. Any part of the software development can be measured. If Software Metrics are implemented in software development, it can save time, money, and allow the organization to identify the caused of defects which have the greatest effect on software development. The summer of 2004, I worked with Cynthia Calhoun and Frank Robinson in the Software Assurance/Risk Management department. My task was to research and collect, compile, and analyze SQA Metrics that have been used in other projects that are not currently being used by the SA team and report them to the Software Assurance team to see if any metrics can be implemented in their software assurance life cycle process.

  3. Creating Quality Assurance and International Transparency for Quality Assurance Agencies

    DEFF Research Database (Denmark)

    Kristoffersen, Dorte; Lindeberg, Tobias

    2004-01-01

    The paper presents the experiences gained in the pilot project on mutual recognition conducted by the quality assurance agencies in the Nordic countries and the future perspective for international quality assurance of national quality assurance agencies. The background of the project was the nee...

  4. Quality assurance in radiotherapy

    International Nuclear Information System (INIS)

    2003-03-01

    Good radiotherapy results and safety of treatment require the radiation to be optimally applied to a specified target area and the correct dose. According to international recommendations, the average uncertainty in therapeutic dose should not exceed 5%. The need for high precision in therapeutic dose requires quality assurance covering the entire radiotherapy process. Besides the physical and technical characteristics of the therapy equipment, quality assurance must include all radiotherapy equipment and procedures that are significant for the correct magnitude and precision of application of the therapeutic dose. The duties and responsibilities pertaining to various stages of treatment must also be precisely defined. These requirements may be best implemented through a quality system. The general requirements for supervision and quality assurance of medical radiation apparatus are prescribed in section 40 of the Radiation Act (592/1991, amendment 1142/1998) and in sections 18 and 32 of the Decree of the Ministry of Social Affairs and Health on the medical use of radiation (423/2000). Guide ST 2.2 imposes requirements on structural radiation shielding of radiotherapy equipment and the premises in which it is used, and on warning and safety arrangements. Guide ST 1.1 sets out the general safety principles for radiation practices and regulatory control procedure for the use of radiation. Guide ST 1.6 provides general requirements for operational measures in the use of radiation. This Guide sets out the duties of responsible parties (the party running a radiation practice) in respect of arranging and maintaining radiotherapy quality assurance. The principles set out in this Guide and Guide ST 6.3 may be applied to radionuclide therapy

  5. BYU Food Quality Assurance Laboratory

    Data.gov (United States)

    Federal Laboratory Consortium — The Quality Assurance Lab is located in the Eyring Science Center in the department of Nutrition, Dietetics, and Food Science. The Quality Assurance Lab has about 10...

  6. Quality assurance program

    International Nuclear Information System (INIS)

    1977-07-01

    This topical report describes the Gibbs and Hill Quality Assurance Program and sets forth the methods to be followed in controlling quality-related activities performed by Gibbs and Hill and its contractors. The program is based on company experience in nuclear power and related work, and defines a system found effective in providing independent control of quality-related functions and documentation. The scope of the report covers activities involving nuclear safety-related structures, systems, and components covered by Gibbs and Hill' contractual obligation to the Utility Owner for each project

  7. Introduction to quality assurance

    International Nuclear Information System (INIS)

    Raisic, N.

    1980-01-01

    Safety requirements set forth in the regulatory requirement, codes, standards as well as other requirements for various aspects of nuclear power plant design and operation are strictly implemented through QA activities. The overall QA aim is to assure that the plant is soundly and correctly designed and that it is built, tested and operated in accordance with stringent quality standards and conservative engineering practices. In this way a high degree of freedom from faults and errors can be achieved. (orig.)

  8. Creating Quality Assurance and International Transparency for Quality Assurance Agencies

    DEFF Research Database (Denmark)

    Kristoffersen, Dorte; Lindeberg, Tobias

    2004-01-01

    , on the one hand, to advance internationalisation of quality assurance of higher education, and on the other hand, allow for the differences in the national approaches to quality assurance. The paper will focus on two issues: first, the strength and weaknesses of the method employed and of the use of the ENQA......The paper presents the experiences gained in the pilot project on mutual recognition conducted by the quality assurance agencies in the Nordic countries and the future perspective for international quality assurance of national quality assurance agencies. The background of the project was the need...

  9. Helical Tomotherapy Quality Assurance

    International Nuclear Information System (INIS)

    Balog, John; Soisson, Emilie

    2008-01-01

    Helical tomotherapy uses a dynamic delivery in which the gantry, treatment couch, and multileaf collimator leaves are all in motion during treatment. This results in highly conformal radiotherapy, but the complexity of the delivery is partially hidden from the end-user because of the extensive integration and automation of the tomotherapy control systems. This presents a challenge to the medical physicist who is expected to be both a system user and an expert, capable of verifying relevant aspects of treatment delivery. A related issue is that a clinical tomotherapy planning system arrives at a customer's site already commissioned by the manufacturer, not by the clinical physicist. The clinical physicist and the manufacturer's representative verify the commissioning at the customer site before acceptance. Theoretically, treatment could begin immediately after acceptance. However, the clinical physicist is responsible for the safe and proper use of the machine. In addition, the therapists and radiation oncologists need to understand the important machine characteristics before treatment can proceed. Typically, treatment begins about 2 weeks after acceptance. This report presents an overview of the tomotherapy system. Helical tomotherapy has unique dosimetry characteristics, and some of those features are emphasized. The integrated treatment planning, delivery, and patient-plan quality assurance process is described. A quality assurance protocol is proposed, with an emphasis on what a clinical medical physicist could and should check. Additionally, aspects of a tomotherapy quality assurance program that could be checked automatically and remotely because of its inherent imaging system and integrated database are discussed

  10. Metrology's role in quality assurance

    International Nuclear Information System (INIS)

    Zeederberg, L.B.

    1982-01-01

    Metrology, the science of measurement, is playing an increasing role in modern industry as part of an on-going quality assurance programme. At Escom, quality assurance was critical during the construction of the Koeberg nuclear facility, and also a function in controlling services provided by Escom. This article deals with the role metrology plays in quality assurance

  11. Quality assurance and quality control

    International Nuclear Information System (INIS)

    Anon.

    1987-01-01

    The practice of nuclear diagnostic imaging requires an appropriate quality assurance program to attain high standards of efficiency and reliability. The International Atomic Energy Agency defines the term quality assurance as ''the closeness with which the outcome of a given procedure approaches some ideal, free from all errors and artifacts.'' The term quality control is used in reference to the specific measures taken to ensure that one particular aspect of the procedure is satisfactory. Therefore, quality assurance is a hospital-wide concept that should involve all aspects of clinical practice. Quality control is concerned with the submission of requests for procedures; the scheduling of patients; the preparation and dispensing of radiopharmaceuticals; the protection of patients, staff, and the general public against radiation hazards and accidents caused by radioactive materials or by faulty equipment; the setting up, use, and maintenance of electronic instruments; the methodology of the actual procedures; the analysis and interpretation of data; the reporting of results; and, finally, the keeping of records. The chapter discusses each of these areas

  12. How much quality assurance?

    International Nuclear Information System (INIS)

    Beatty, R.A.; Talboy, J.H.

    1988-01-01

    This paper describes the approach used at Argonne National Laboratory to apply the techniques of quality assurance to research and development activities. The discussion includes the approach, the reasons that it is gaining acceptance, and its wide applicability. This approach is founded on the lessons learned in management of quality at Argonne National Laboratory over a period of more than 15 years. The discussion is confined to the practices at the Illinois site of the Laboratory where more than 3000 researchers and support personnel conduct basic and technology-directed research

  13. Quality assurance services

    International Nuclear Information System (INIS)

    For over 20 years the quality assurance services at the Springfields Laboratories have been concerned with manufacturing both simple and complex engineering products to the highest standard. The scientists working there have considerable expertise in the practical application of quality control and the development and design of inspection and non-destructive testing equipment. The folder contains six sheets or leaflets illustrating the work and equipment. The subjects are the mechanical standards laboratory, non-destructive testing, the digitising table, the peripheral camera, automated measurement, data handling and presentation, and the computer controlled three axis co-ordinate measuring machine. (U.K.)

  14. Quality assurance and reliability

    International Nuclear Information System (INIS)

    Normand, J.; Charon, M.

    1975-01-01

    Concern for obtaining high-quality products which will function properly when required to do so is nothing new - it is one manifestation of a conscientious attitude to work. However, the complexity and cost of equipment and the consequences of even temporary immobilization are such that it has become necessary to make special arrangements for obtaining high-quality products and examining what one has obtained. Each unit within an enterprise must examine its own work or arrange for it to be examined; a unit whose specific task is quality assurance is responsible for overall checking, but does not relieve other units of their responsibility. Quality assurance is a form of mutual assistance within an enterprise, designed to remove the causes of faults as far as possible. It begins very early in a project and continues through the ordering stage, construction, start-up trials and operation. Quality and hence reliability are the direct result of what is done at all stages of a project. They depend on constant attention to detail, for even a minor piece of poor workmanship can, in the case of an essential item of equipment, give rise to serious operational difficulties

  15. Quality assurance for geologic investigations

    International Nuclear Information System (INIS)

    Delvin, W.L.; Gustafson, L.D.

    1983-01-01

    A quality assurance handbook was written to provide guidance in the application of quality assurance to geologic work activities associated with the National Waste Terminal Storage (NWTS) Program. It is intended to help geoscientists and NWTS program managers in applying quality assurance to their work activities and projects by showing how technical and quality assurance practices are integrated to provide control within those activities and projects. The use of the guidance found in this handbook should help provide consistency in the interpretation of quality assurance requirements across the various geologic activities wihtin the NWTS Program. This handbook also can assist quality assurance personnel in understanding the relationships between technical and quality assurance practices. This paper describes the handbook

  16. Quality assurance for geologic investigations

    International Nuclear Information System (INIS)

    Delvin, W.L.; Gustafson, L.D.

    1983-01-01

    A quality assurance handbook was written to provide guidance in the application of quality assurance to geologic work activities associated with the National Waste Terminal Storage (NWTS) Program. It is intended to help geoscientists and NWTS program managers in applying quality assurance to their work activitie and projects by showing how technical and quality assurance practices are integrated to provide control within those activities and projects. The use of the guidance found in this handbook should help provide consistency in the interpretation of quality assurance requirements across the various geologic activities within the NWTS Program. This handbook also can assist quality assurance personnel in understanding the relationships between technical and quality assurance practices. This paper describes the handbook

  17. Quality assurance records system

    International Nuclear Information System (INIS)

    1979-01-01

    This Safety Guide was prepared as part of the Agency's programme, referred to as the NUSS programme, for establishing Codes of Practice and Safety Guides relating to nuclear power plants. It supplements the IAEA Code of Practice on Quality Assurance for Safety in Nuclear Power Plants (IAEA Safety Series No.50-C-QA), which requires that for each nuclear power plant a system for the generation, identification, collection, indexing, filing, storing, maintenance and disposition of quality assurance records shall be established and executed in accordance with written procedures and instructions. The purpose of this Safety Guide is to provide assistance in the establishment and operation of such a system. An orderly established and maintained records system is considered to be part of the means of providing a basis for an appropriate level of confidence that the activities which affect the quality of a nuclear power plant have been performed in accordance with the specific requirements and that the required quality has been achieved and is maintained

  18. The quality assurance liaison: Combined technical and quality assurance support

    International Nuclear Information System (INIS)

    Bolivar, S.L.; Day, J.L.

    1993-01-01

    This paper describes the role of the quality assurance liaison, the responsibilities of this position, and the evolutionary changes in duties over the last six years. The role of the quality assurance liaison has had a very positive impact on the Los Alamos Yucca Mountain Site Characterization (YW) quality assurance program. Having both technical and quality assurance expertise, the quality assurance liaisons are able to facilitate communications with scientists on quality assurance issues and requirements, thereby generating greater productivity in scientific investigations. The quality assurance liaisons help ensure that the scientific community knows and implements existing requirements, is aware of new or changing regulations, and is able to conduct scientific work within Project requirements. The influence of the role of the quality assurance liaison can be measured by an overall improvement in attitude of the staff regarding quality assurance requirements and improved job performance, as well as a decrease in deficiencies identified during both internal and external audits and surveillances. This has resulted in a more effective implementation of quality assurance requirements

  19. Quality assurance and product quality

    International Nuclear Information System (INIS)

    Lacroix, D.; Bastiani, P. de

    2004-01-01

    The basic quality assurance requirements have to be completed by means that are oriented towards the quality of products; in COGEMA LOGISTICS our approach is based on four principles: 1) an integrated management system: Quality, health and safety, environment 2) an organization based on the responsibility of all actors, trust and transparency 3) a methodical approach to continuously improve the methods that are employed to achieve quality: -process management -corrective and preventive actions -self assessments and various surveys 4) but at the same time strong procedures for control and monitoring of all activities: -technical and quality audits (external and internal) -at source inspections -engineering activities inspections This performance-based approach is necessary to guaranty the effectiveness of the traditional formal QA means

  20. Hyperthermia quality assurance

    International Nuclear Information System (INIS)

    Shrivastava, P.N.; Paliwal, B.R.

    1984-01-01

    Hyperthermia Physics Center (HPC) operating under contract with the National Cancer Institute is developing a Quality Assurance program for local and regional hyperthermia. The major clinical problem in hyperthermia treatments is that they are extremely difficult to plan, execute, monitor and reproduce. A scientific basis for treatment planning can be established only after ensuring that the performance of heat generating and temperature monitoring systems are reliable. The HPC is presently concentrating on providing uniform NBS traceable calibration of thermometers and evaluation of reproducibility for power generator operation, applicator performance, phanta compositions, system calibrations and personnel shielding. The organizational plan together with recommended evaluation measurements, procedures and criteria are presented

  1. Concrete quality assurance

    Energy Technology Data Exchange (ETDEWEB)

    Holz, N. [Harza Engineering Company, Chicago, IL (United States)

    2000-08-01

    This short article reports on progress at the world's largest civil construction project, namely China's Three Gorges hydro project. Work goes on around the clock to put in place nearly 28 M m{sup 3} of concrete. At every stage of the work there is strong emphasis on quality assurance (QA) and concrete is no exception. The US company Harza Engineering has been providing QA since the mid-1980s and concrete QA has been based on international standards. Harza personnel work in the field with supervisors developing educational tools for supervising concrete construction and quality, as well as providing training courses in concrete technology. Some details on flood control, capacity, water quality and environmental aspects are given..

  2. Quality assurance in the nuclear test program

    International Nuclear Information System (INIS)

    Shearer, J.N.

    1979-01-01

    In February 1979 Test Program laid the ground work for a new quality assurance structure. The new approach was based on the findings and recommendations of the Ad Hoc QA Program Review panel, which are summarized in this report. The new structure places the responsibility for quality assurance in the hands of the line organizations, both in the programmatic and functional elements of the LLL matrix

  3. Quality assurance and accreditation.

    Science.gov (United States)

    1997-01-01

    In 1996, the Joint Commission International (JCI), which is a partnership between the Joint Commission on Accreditation of Healthcare Organizations and Quality Healthcare Resources, Inc., became one of the contractors of the Quality Assurance Project (QAP). JCI recognizes the link between accreditation and quality, and uses a collaborative approach to help a country develop national quality standards that will improve patient care, satisfy patient-centered objectives, and serve the interest of all affected parties. The implementation of good standards provides support for the good performance of professionals, introduces new ideas for improvement, enhances the quality of patient care, reduces costs, increases efficiency, strengthens public confidence, improves management, and enhances the involvement of the medical staff. Such good standards are objective and measurable; achievable with current resources; adaptable to different institutions and cultures; and demonstrate autonomy, flexibility, and creativity. The QAP offers the opportunity to approach accreditation through research efforts, training programs, and regulatory processes. QAP work in the area of accreditation has been targeted for Zambia, where the goal is to provide equal access to cost-effective, quality health care; Jordan, where a consensus process for the development of standards, guidelines, and policies has been initiated; and Ecuador, where JCI has been asked to help plan an approach to the evaluation and monitoring of the health care delivery system.

  4. Quality-Assurance Program Plan

    International Nuclear Information System (INIS)

    Kettell, R.A.

    1981-05-01

    This Quality Assurance Program Plan (QAPP) is provided to describe the Quality Assurance Program which is applied to the waste management activities conducted by AESD-Nevada Operations at the E-MAD Facility located in Area 25 of the Nevada Test Site. The AESD-Nevada Operations QAPP provides the necessary systematic and administrative controls to assure activities that affect quality, safety, reliability, and maintainability during design, procurement, fabrication, inspection, shipments, tests, and storage are conducted in accordance with established requirements

  5. Towards improvement in quality assurance

    International Nuclear Information System (INIS)

    1987-03-01

    This first document in the series of the International Nuclear Safety Advisory Group (INSAG) Technical Notes is a general guideline for the establishment of effective quality assurance procedures at nuclear facilities. It sets out primary requirements such as quality objectives, methods for measuring the effectiveness of the quality assurance programme, priority of activities in relation to importance of safety of items, motivation of personnel

  6. Quality assurance of fuel elements

    International Nuclear Information System (INIS)

    Hoerber, J.

    1980-01-01

    The quality assurance activities for reactor fuel elements are based on a quality assurance system which implies the requirements resulting from the specifications, regulations of the authorities, national standards and international rules and regulations. The quality assurance related to production of reactor fuel will be shown for PWR fuel elements in all typical fabrication steps as conversion into UO 2 -powder, pelletizing, rodmanufacture and assembling. A wide range of destructive and nondestructive techniques is applied. Quality assurance is not only verified by testing techniques but also by process monitoring by means of parameter control in production and testing procedures. (RW)

  7. FESA Quality Assurance

    CERN Multimedia

    CERN. Geneva

    2015-01-01

    FESA is a framework used by 100+ developers at CERN to design and implement the real-time software used to control the accelerators. Each new version must be tested and qualified to ensure that no backward compatibility issues have been introduced and that there is no major bug which might prevent accelerator operations. Our quality assurance approach is based on code review and a two-level testing process. The first level is made of unit-test (Python unittest & Google tests for C++). The second level consists of integration tests running on an isolated test environment. We also use a continuous integration service (Bamboo) to ensure the tests are executed periodically and the bugs caught early. In the presentation, we will explain the reasons why we took this approach, the results and some thoughts on the pros and cons.

  8. Subsurface quality assurance practices

    International Nuclear Information System (INIS)

    1987-08-01

    This report addresses only the concept of applying Nuclear Quality Assurance (NQA) practices to repository shaft and subsurface design and construction; how NQA will be applied; and the level of detail required in the documentation for construction of a shaft and subsurface repository in contrast to the level of detail required in the documentation for construction of a traditional mine. This study determined that NQA practices are viable, attainable, as well as required. The study identified the appropriate NQA criteria and the repository's major structures, systems, items, and activities to which the criteria are applicable. A QA plan, for design and construction, and a list of documentation, for construction, are presented. 7 refs., 1 fig., 18 tabs

  9. Construction quality assurance report

    International Nuclear Information System (INIS)

    Roscha, V.

    1994-01-01

    This report provides a summary of the construction quality assurance (CQA) observation and test results, including: The results of the geosynthetic and soil materials conformance testing. The observation and testing results associates with the installation of the soil liners. The observation and testing results associated with the installation of the HDPE geomembrane liner systems. The observation and testing results associated with the installation of the leachate collection and removal systems. The observation and testing results associated with the installation of the working surfaces. The observation and testing results associated with in-plant manufacturing process. Summary of submittal reviews by Golder Construction Services, Inc. The submittal and certification of the piping material specifications. The observation and verification associated of the Acceptance Test Procedure results of the operational equipment functions. Summary of the ECNs which are incorporated into the project

  10. Quality assurance and quality control

    International Nuclear Information System (INIS)

    Kaden, W.

    1986-01-01

    General preconditions and methods for QA work in the nuclear field are analysed. The application of general QA principles to actual situations is illustrated by examples in the fields of engineering and of the manufacturing of mechanical and electrical components. All QA measures must be fitted to the complexity and relevance of the work steps, which are under consideration. The key to good product quality is the control of working processes. The term 'controlled process' is discussed in detail and examples of feed back systems are given. The main QA measures for the operation of nuclear power plants include the establishment of a Quality Assurance Program, training and qualification of personnel, procurement control, inspection and tests, reviews and audits. These activities are discussed. (orig.)

  11. Recent Trends in Quality Assurance

    Science.gov (United States)

    Amaral, Alberto; Rosa, Maria Joao

    2010-01-01

    In this paper we present a brief description of the evolution of quality assurance in Europe, paying particular attention to its relationship to the rising loss of trust in higher education institutions. We finalise by analysing the role of the European Commission in the setting up of new quality assurance mechanisms that tend to promote…

  12. Quality assurance of operating instructions

    International Nuclear Information System (INIS)

    Asmuss, G.

    1992-01-01

    It is pointed out that the quality assurance at nuclear power stations must be supported by national and international regulations. Quality assurance is explained using the example of the design of a pressurised water reactor. The operating and emergency manuals are discussed and examples for their structure put forward. The significance of updating is emphasised. 15 figs., 19 refs

  13. Project Specific Quality Assurance Plan

    International Nuclear Information System (INIS)

    Pedersen, K.S.

    1995-01-01

    This Quality Assurance Project Plan (QAPP) identifies the Westinghouse Hanford Co. (WHC) Quality Assurance (QA) program requirements for all contractors involved in the planning and execution of the design, construction, testing and inspection of the 200 Area Effluent BAT/AKART Implementation, Project W-291

  14. An overview of quality assurance

    International Nuclear Information System (INIS)

    Morris, I.T.

    1983-01-01

    A good quality assurance program seeks to minimise radiation exposure and maximise image quality. Factors considered are equipment performance, films and screens, film processing, viewing conditions and film repeats

  15. Quality Assurance Training Tracking (QATTS)

    Data.gov (United States)

    U.S. Environmental Protection Agency — This is metadata documentation for the Quality Assurance Training Tracking System (QATTS) which tracks Quality Assurace training given by R7 QA staff to in-house...

  16. Material quality assurance risk assessment.

    Science.gov (United States)

    2013-01-01

    Over the past two decades the role of SHA has shifted from quality control (QC) of materials and : placement techniques to quality assurance (QA) and acceptance. The role of the Office of Materials : Technology (OMT) has been shifting towards assuran...

  17. Ballistic quality assurance

    International Nuclear Information System (INIS)

    Cassol, E.; Bonnet, J.; Porcheron, D.; Mazeron, J.J.; Peiffert, D.; Alapetite, C.

    2012-01-01

    This review describes the ballistic quality assurance for stereotactic intracranial irradiation treatments delivered with Gamma Knife R either dedicated or adapted medical linear accelerators. Specific and periodic controls should be performed in order to check the mechanical stability for both irradiation and collimation systems. If this step remains under the responsibility of the medical physicist, it should be done in agreement with the manufacturer's technical support. At this time, there are no recent published guidelines. With technological developments, both frequency and accuracy should be assessed in each institution according to the treatment mode: single versus hypo-fractionated dose, circular collimator versus micro-multi-leaf collimators. In addition, 'end-to-end' techniques are mandatory to find the origin of potential discrepancies and to estimate the global ballistic accuracy of the delivered treatment. Indeed, they include frames, non-invasive immobilization devices, localizers, multimodal imaging for delineation and in-room positioning imaging systems. The final precision that could be reasonably achieved is more or less 1 mm. (authors)

  18. Software Quality Assurance Audits Guidebooks

    Science.gov (United States)

    1990-01-01

    The growth in cost and importance of software to NASA has caused NASA to address the improvement of software development across the agency. One of the products of this program is a series of guidebooks that define a NASA concept of the assurance processes that are used in software development. The Software Assurance Guidebook, NASA-GB-A201, issued in September, 1989, provides an overall picture of the NASA concepts and practices in software assurance. Second level guidebooks focus on specific activities that fall within the software assurance discipline, and provide more detailed information for the manager and/or practitioner. This is the second level Software Quality Assurance Audits Guidebook that describes software quality assurance audits in a way that is compatible with practices at NASA Centers.

  19. Modernization of software quality assurance

    Science.gov (United States)

    Bhaumik, Gokul

    1988-01-01

    The customers satisfaction depends not only on functional performance, it also depends on the quality characteristics of the software products. An examination of this quality aspect of software products will provide a clear, well defined framework for quality assurance functions, which improve the life-cycle activities of software development. Software developers must be aware of the following aspects which have been expressed by many quality experts: quality cannot be added on; the level of quality built into a program is a function of the quality attributes employed during the development process; and finally, quality must be managed. These concepts have guided our development of the following definition for a Software Quality Assurance function: Software Quality Assurance is a formal, planned approach of actions designed to evaluate the degree of an identifiable set of quality attributes present in all software systems and their products. This paper is an explanation of how this definition was developed and how it is used.

  20. Quality assurance in nuclear medicine

    International Nuclear Information System (INIS)

    Kaul, A.

    1986-01-01

    'Quality Assurance in Nuclear Medicine' is the title of the English language original that has been translated into German. The manual very extensively deals with quality control of nuclear medical equipment. Tests are explained for checking radioactivity measuring devices, manual and automatic in-vitro sample measuring systems, in-vivo measuring systems with single or multiple detectors, rectlinear scanners, and gamma cameras, including the phantoms required for the methods. Other chapters discuss the quality control of radiopharmaceuticals, or the quality assurance in data recording and evaluation of results. Helpful comments on the organisation of quality assurance programms are given. The book is intended as a practical guide for introducing quality assurance principles in nuclear medicine in the Federal Republic of Germany. With 13 figs., 22 tabs [de

  1. Quality assurance during site construction

    International Nuclear Information System (INIS)

    Dommke, J.; Jurgutat, H.

    1980-01-01

    During the time of planing and construction of a nuclear power plant, the following proceeding is approved: - the deliverer of a nuclear power plant provides the reports fixing the quality assurance program, it means that he is responsible to write the safety analysis report, the specifications for the erection of the components, the working manuals and specifications for testing (eg nondestr. testing) - the manufacturing of components or systems will be controlled by an own independent quality assurance group, provided that this group was checked by the quality assurance group of the applicant - the TUeV with its independent assessors will fix the requirements relating to quality assurance in its assessment. On this basis the examination of the applicants specifications, working manuals, testing specifications will be done. The efficiency of quality assurance at the manufacturer and at the applicant will be checked by the TUeV specialists by considering specifications of modifications, repairs or tolerances. A mean point of the quality assurance in Germany is the dynamic adjustment, of an action on the latest state of engineering or science. If there exists a change of rules or guidelines, the quality assurance requirements have to be fit on this state in so far as it is feasible from the technical point of view. (orig./RW)

  2. Radiation shielding quality assurance

    Science.gov (United States)

    Um, Dallsun

    For the radiation shielding quality assurance, the validity and reliability of the neutron transport code MCNP, which is now one of the most widely used radiation shielding analysis codes, were checked with lot of benchmark experiments. And also as a practical example, follows were performed in this thesis. One integral neutron transport experiment to measure the effect of neutron streaming in iron and void was performed with Dog-Legged Void Assembly in Knolls Atomic Power Laboratory in 1991. Neutron flux was measured six different places with the methane detectors and a BF-3 detector. The main purpose of the measurements was to provide benchmark against which various neutron transport calculation tools could be compared. Those data were used in verification of Monte Carlo Neutron & Photon Transport Code, MCNP, with the modeling for that. Experimental results and calculation results were compared in both ways, as the total integrated value of neutron fluxes along neutron energy range from 10 KeV to 2 MeV and as the neutron spectrum along with neutron energy range. Both results are well matched with the statistical error +/-20%. MCNP results were also compared with those of TORT, a three dimensional discrete ordinates code which was developed by Oak Ridge National Laboratory. MCNP results are superior to the TORT results at all detector places except one. This means that MCNP is proved as a very powerful tool for the analysis of neutron transport through iron & air and further it could be used as a powerful tool for the radiation shielding analysis. For one application of the analysis of variance (ANOVA) to neutron and gamma transport problems, uncertainties for the calculated values of critical K were evaluated as in the ANOVA on statistical data.

  3. R D software quality assurance

    Energy Technology Data Exchange (ETDEWEB)

    Hood, F.C.

    1991-10-01

    Research software quality assurance (QA) requirements must be adequate to strengthen development or modification objectives, but flexible enough not to restrict creativity. Application guidelines are needed for the different kinds of research and development (R D) software activities to assure project objectives are achieved.

  4. Quality assurance in plant engineering

    International Nuclear Information System (INIS)

    Ohsumi, Morimichi

    1977-01-01

    Quality assurance is defined as the intentional and systematic activity carried out to obtain such reliability that the functions of nuclear power generating plants are demonstrated during the plant operation, and the section in charge has the role to organize, adjust and communicate so that the related sections can work smoothly. There are many documents concerning the quality assurance, such as quality assurance basic program, quality assurance manual, quality control plan and its manual and many specifications, etc. The content of the quality assurance is different for every step of plant planning such as at inquiry and order receiving, and prior to manufacturing, for example, inspection specification being decided for the material and the welded parts of classified pipings at the step of order receiving. Document management, engineering schedule and the custody of quality records are also quality assurance activities. Design management is controlled step by step; plant planning including safety analysis, overall layout plan, conceptual design of buildings, aseismatic design guide, heat balance and so on, system design mainly with system description, piping design including piping specification, standard dimensions of edge preparation, piping and valve lists, inspection manual, etc., detailed design, standardization of piping and design review, etc. are explained. The management of the intermediate between soft and hard parts consists of the quality check for material manufacturers and shipment inspection, etc. (Nakai, Y.)

  5. Managerial attitude toward quality assurance

    International Nuclear Information System (INIS)

    Kirschenmann, H.J.

    1983-01-01

    This paper will present what relationships exist between the attitude toward quality assurance and the variables of training and experience on the part of managers within the nuclear power industry. Managerial attitude toward quality assurance was measured via questionnaires submitted to managers within architect-engineering, nuclear steam supplier, and constructor firms throughout the United States. The data from the completed questionnaires were statistically analyzed using the chi-square test and conclusions were drawn. Additional study results related to major factors for positive and negative attitudes toward quality assurance will be presented

  6. Quality assurance of polymer concrete

    International Nuclear Information System (INIS)

    Schulz, H.

    1984-01-01

    With polymer concrete, a whole range of organisational and functional measures have to be met in order to assure the required quality with an economic expenditure. Quality assurance begins in the design and does not end in the production, rather includes all fields of the enterprise. The following deals with a particular range of the total complex, the inspection methods for assuring the quality of machine components of polymer concrete, particularly machine tool bases, this being through the control of the raw material, the production and the finished product. (orig.) [de

  7. Methods of Software Quality Assurance under a Nuclear Quality Assurance Program

    International Nuclear Information System (INIS)

    Kim, Jang Yeol; Lee, Young Jun; Cha, Kyung Ho; Cheon, Se Woo; Lee, Jang Soo; Kwon, Kee Choon

    2005-01-01

    This paper addresses a substantial implementation of a software quality assurance under a nuclear quality assurance program. The relationship of the responsibility between a top-level nuclear quality assurance program such as ASME/NQA-1 and its lower level software quality assurance is described. Software quality assurance activities and software quality assurance procedures during the software development life cycle are also described

  8. BUILDING "BRIDGES" WITH QUALITY ASSURANCE

    Science.gov (United States)

    The papr describes how, rather than building "bridges" across centuries, quality assurance (QA) personnel have the opportunity to build bridges across technical disciplines, between public and private organizations, and between different QA groups. As reviewers and auditors of a...

  9. QANU - Quality Assurance Netherlands Universities

    DEFF Research Database (Denmark)

    Jensen, Henrik Toft; Maria E., Weber; Vyt, André

    The Quality Assurance Netherlands Universities (QANU) underwent an ENQA-coordinated external review in 2016. The review was chaired by Henrik Toft Jensen, Research fellow at Roskilde University (RUC), Denmark....

  10. System management and quality assurance

    International Nuclear Information System (INIS)

    Sastry, A.M.

    1989-01-01

    This paper describes the principles of system management and shows the relationship to quality assurance. It discusses the need for balanced attention to all the project management controls required for project success

  11. Quality assurance within regulatory bodies

    International Nuclear Information System (INIS)

    1999-06-01

    The IAEA directed extensive efforts during the years 1991 to 1995 to the integral revision of all NUSS quality assurance publications, which were approved and issued as Safety Series No.50-C/SG-Q, Quality Assurance for Safety in Nuclear Power Plants and other Nuclear Installations (1996). When these quality assurance publications were developed, their prime focus was on requirements against which work performed by the licensees could be measured and assessed by the regulatory bodies. In this way, they only helped to facilitate the functions of regulators. No requirements or recommendations were provided on how the regulators should ensure the effective implementation of their own activities. The present publication is a first attempt to collect, integrate and offer available experience to directly support performance of regulatory activities. It presents a comprehensive compilation on the application of quality assurance principles and methods by regulatory bodies to their activities. The aim is consistent good performance of regulatory activities through a systematic approach

  12. Redefining and expanding quality assurance.

    Science.gov (United States)

    Robins, J L

    1992-12-01

    To meet the current standards of excellence necessary for blood establishments, we have learned from industry that a movement toward organization-wide quality assurance/total quality management must be made. Everyone in the organization must accept responsibility for participating in providing the highest quality products and services. Quality must be built into processes and design systems to support these quality processes. Quality assurance has been redefined to include a quality planning function described as the most effective way of designing quality into processes. A formalized quality planning process must be part of quality assurance. Continuous quality improvement has been identified as the strategy every blood establishment must support while striving for error-free processing as the long-term objective. The auditing process has been realigned to support and facilitate this same objective. Implementing organization-wide quality assurance/total quality management is one proven plan for guaranteeing the quality of the 20 million products that are transfused into 4 million patients each year and for moving toward the new order.

  13. Quality management and quality assurance contracts

    International Nuclear Information System (INIS)

    Teichler, M.

    1991-01-01

    Quality assurance contracts belong to the most important instruments of quality management systems. As a result of such contracts, quality control is to be done not only by the buyer, but is made a task to be fulfilled by the manufacturer. The author of the article shows that quality assurance contracts do change the contractual relationship between supplier and buyer, but have no effect on economic and practical conditions. This is so because quality assurance contracts apply only to warranty claims, which play a subordinate role in the legal relationship between producer and buyer, or producer and consumer, as compared to the claims for damages arising out of the contracts. (orig.) [de

  14. Quality assurance issues and PACS

    NARCIS (Netherlands)

    Banta, H.D.

    1992-01-01

    Quality assessment and assurance is a growing concern in all areas of health care. The concern is fueled by a body of evidence that indicates that quality of care is not optimal, and in many instances, is unacceptably low. Although different standards for quality have been proposed, health outcome

  15. [Quality assurance in interventional cardiology].

    Science.gov (United States)

    Gülker, H

    2009-10-01

    Quality assurance in clinical studies aiming at approval of pharmaceutical products is submitted to strict rules, controls and auditing regulations. Comparative instruments to ensure quality in diagnostic and therapeutic procedures are not available in interventional cardiology, likewise in other fields of cardiovascular medicine. Quality assurance simply consists of "quality registers" with basic data not externally controlled. Based on the experiences of clinical studies and their long history of standardization it is assumed that these data may be severely flawed thus being inappropriate to set standards for diagnostic and therapeutic strategies. The precondition for quality assurance are quality data. In invasive coronary angiography and intervention medical indications, the decision making process interventional versus surgical revascularization, technical performance and after - care are essential aspects affecting quality of diagnostics and therapy. Quality data are externally controlled data. To collect quality data an appropriate infrastructure is a necessary precondition which is not existent. For an appropriate infrastructure investments have to be done both to build up as well as to sustain the necessary preconditions. As long as there are no infrastructure and no investments there will be no "quality data". There exist simply registers of data which are not proved to be a basis for significant assurance and enhancement in quality in interventional coronary cardiology. Georg Thieme Verlag KG Stuttgart, New York.

  16. Quality assurance in nuclear medicine

    International Nuclear Information System (INIS)

    Paras, P.

    1978-01-01

    Quality assurance practices must be followed throughout the entire nuclear medicine process, from the initial decision to perform a particular procedure, through the interpretation and reporting of the results. The various parameters that can be defined and measured in each area must be monitored by quality control tests to assure the excellence of the total nuclear medicine process. The presentation will discuss each of the major areas of nuclear medicine quality control and their interaction as a part of the entire system. Quality control testing results and recommendations for measurements of radioactivity distribution will be described with emphasis on imaging equipment and dose calibrating instrumentation. The role of the health physicist in a quality assurance program will be stressed. (author)

  17. Thoughts on Internal and External Quality Assurance

    Science.gov (United States)

    Zhang, Jianxin

    2012-01-01

    Quality assurance of higher education is made up of two parts: internal quality assurance (IQA) and external quality assurance (EQA). Both belong to a union of the coexistence and balance of yin and yang. But in reality there exists a paradox of "confusion of quality assurance (QA) subject consciousness, singularity of social QA and lack of QA…

  18. 10 CFR 71.37 - Quality assurance.

    Science.gov (United States)

    2010-01-01

    ... 10 Energy 2 2010-01-01 2010-01-01 false Quality assurance. 71.37 Section 71.37 Energy NUCLEAR... Package Approval § 71.37 Quality assurance. (a) The applicant shall describe the quality assurance program... quality assurance program that are applicable to the particular package design under consideration...

  19. Grading of quality assurance requirements

    International Nuclear Information System (INIS)

    1991-01-01

    The present Manual provides guidance and illustrative examples for applying a method by which graded quality assurance requirements may be determined and adapted to the items and services of a nuclear power plant in conformance with the requirements of the IAEA Nuclear Safety Standards (NUSS) Code and Safety Guides on quality assurance. The Manual replaces the previous publication IAEA-TECDOC-303 on the same subject. Various methods of grading quality assurance are available in a number of Member States. During the development of the present Manual it was not considered practical to attempt to resolve the differences between those methods and it was preferred to identify and benefit from the good practices available in all the methods. The method presented in this Manual deals with the aspects of management, documentation, control, verification and administration which affect quality. 1 fig., 4 tabs

  20. Quality assurance of qualitative analysis

    DEFF Research Database (Denmark)

    Ríos, Ángel; Barceló, Damiá; Buydens, Lutgarde

    2003-01-01

    The European Commission has supported the G6MA-CT-2000-01012 project on "Metrology of Qualitative Chemical Analysis" (MEQUALAN), which was developed during 2000-2002. The final result is a document produced by a group of scientists with expertise in different areas of chemical analysis, metrology...... and quality assurance. One important part of this document deals, therefore, with aspects involved in analytical quality assurance of qualitative analysis. This article shows the main conclusions reported in the document referring to the implementation of quality principles in qualitative analysis...

  1. Quality Assurance 1992-2012

    Science.gov (United States)

    Brown, Roger

    2012-01-01

    As the author's contribution to a series marking the Golden Jubilee of the Association of University Administrators, he reflects on changes in quality assurance over the past twenty years and speculates on what the future may hold for quality as the association moves into a new and very different competitive regime. He begins by discussing the…

  2. Quality assurance during site construction

    International Nuclear Information System (INIS)

    Eymess, K.J.; Haas, R.; Wellnitz, G.

    1980-01-01

    Quality Assurance for Nuclear Power Plants under consideration of pipe assembling. Flow of Quality Requirements during: - Desing - Construction - Procurement - Prefabrication - Site. Organizational Requirements and Measurements during Erection: - Incoming Control - Material Storage - Surveillance of Tools - Weld Surveillance - Nondestructive Testing - Cleaning - Final Documentation. Qualification and Training of QA Personnel. (orig.)

  3. Quality assurance in mammography

    International Nuclear Information System (INIS)

    Fosmark, H.; Olerud, H.M.

    1992-01-01

    Guidelines in mammography are given, including competence of staff, performance of equipment and quality control procedures. The purpose of the guidelines is to ensure optimum diagnostic quality. 5 refs

  4. Quality assurance handbook for measurement laboratories

    International Nuclear Information System (INIS)

    Delvin, W.L.

    1984-10-01

    This handbook provides guidance in the application of quality assurance to measurement activities. It is intended to help those persons making measurements in applying quality assurance to their work activities by showing how laboratory practices and quality assurance requirements are integrated to provide control within those activities. The use of the guidance found in this handbook should help provide consistency in the interpretation of quality assurance requirements across all types of measurement laboratories. This handbook also can assist quality assurance personnel in understanding the relationships between laboratory practices and quality assurance requirements. The handbook is composed of three chapters and several appendices. Basic guidance is provided by the three chapters. In Chapter 1, the role of quality assurance in obtaining quality data and the importance of such data are discussed. Chapter 2 presents the elements of laboratory quality assurance in terms of practices that can be used in controlling work activities to assure the acquisition of quality data. Chapter 3 discusses the implementation of laboratory quality assurance. The appendices provide supplemental information to give the users a better understanding of the following: what is quality assurance; why quality assurance is required; where quality assurance requirements come from; how those requirements are interpreted for application to laboratory operations; how the elements of laboratory quality assurance relate to various laboratory activities; and how a quality assurance program can be developed

  5. Concepts of nuclear quality assurance

    International Nuclear Information System (INIS)

    Randers, G.; Morris, P.A.; Pomeroy, D.

    1976-01-01

    While the safety record of the nuclear industry continues to be excellent, the forced outage rates for recent years continue to be 15% or more. Quality assurance, therefore, needs to be applied not only to nuclear safety matters, but to the goals of increased productivity and reduced construction and operating costs. Broadening the application of the general concept of quality assurance in this way leads to the introduction of reliability technology. The total activity might better be called reliability assurance. That effective quality assurance systems do pay off is described by examples from the utility industry, from a manufacturer of instruments and systems and from the experience of Westinghouse Electric Company's manufacturing divisions. The special situation of applying quality assurance to nuclear fuel is discussed. Problems include the lack of a fully developed regulatory policy in this area, incomplete understanding of the mechanism for pellet-clad interaction failures, incomplete access to manufacturers design and process information, inability to make desirable changes on a timely basis and inadequate feedback of irradiation experience. (author)

  6. Waste Management Quality Assurance Plan

    International Nuclear Information System (INIS)

    1993-01-01

    Lawrence Berkeley Laboratory's Environment Department addresses its responsibilities through activities in a variety of areas. The need for a comprehensive management control system for these activities has been identified by the Department of Energy (DOE). The WM QA (Waste Management Quality Assurance) Plan is an integral part of a management system that provides controls necessary to ensure that the department's activities are planned, performed, documented, and verified. This WM QA Plan defines the requirements of the WM QA program. These requirements are derived from DOE Order 5700.6C, Quality Assurance, the LBL Operating and Assurance Program Plan (OAP, LBL PUB-3111), and other environmental compliance documents applicable to WM activities. The requirements presented herein, as well as the procedures and methodologies that direct the implementation of these requirements, will undergo review and revisions as necessary. The provisions of this QA Plan and its implementing documents apply to quality-affecting activities performed by and for WM. It is also applicable to WM contractors, vendors, and other LBL organizations associated with WM activities, except where such contractors, vendors, or organizations are governed by their own WM-approved QA programs. References used in the preparation of this document are (1) ASME NQA-1-1989, (2) ANSI/ASQC E4 (Draft), (3) Waste Management Quality Assurance Implementing Management Plan (LBL PUB-5352, Rev. 1), (4) LBL Operating and Assurance Program Plan (OAP), LBL PUB-3111, 2/3/93. A list of terms and definitions used throughout this document is included as Appendix A

  7. Waste Management Quality Assurance Plan

    International Nuclear Information System (INIS)

    2006-01-01

    The WMG QAP is an integral part of a management system designed to ensure that WMG activities are planned, performed, documented, and verified in a manner that assures a quality product. A quality product is one that meets all waste acceptance criteria, conforms to all permit and regulatory requirements, and is accepted at the offsite treatment, storage, and disposal facility. In addition to internal processes, this QA Plan identifies WMG processes providing oversight and assurance to line management that waste is managed according to all federal, state, and local requirements for waste generator areas. A variety of quality assurance activities are integral to managing waste. These QA functions have been identified in the relevant procedures and in subsequent sections of this plan. The WMG QAP defines the requirements of the WMG quality assurance program. These requirements are derived from Department of Energy (DOE) Order 414.1C, Quality Assurance, Contractor Requirements Document, the LBNL Operating and Assurance Program Plan (OAP), and other applicable environmental compliance documents. The QAP and all associated WMG policies and procedures are periodically reviewed and revised, as necessary, to implement corrective actions, and to reflect changes that have occurred in regulations, requirements, or practices as a result of feedback on work performed or lessons learned from other organizations. The provisions of this QAP and its implementing documents apply to quality-affecting activities performed by the WMG; WMG personnel, contractors, and vendors; and personnel from other associated LBNL organizations, except where such contractors, vendors, or organizations are governed by their own WMG-approved QA programs

  8. Quality assurance in medical laboratories

    International Nuclear Information System (INIS)

    Boroviczeny, K.G. von; Merten, R.; Merten, U.P.

    1987-01-01

    The book presents a comprehensive and specified survey of the quality assurance measures and methods applied in medical laboratories in the pre-analytical phase and in the analytical and post-analytical phases. It also gives information on computer-aided procedures, cost-benefit analyses in this field, and on official requirements and standards in the fields of clinical chemistry, hematology, immunology and microbiology, and equipment testing and inspection. One chapter of the book particularly deals with quality assurance for radioimmunological in-vitro analyses. With 112 figs., 337 tabs [de

  9. The challenge of quality assurance

    International Nuclear Information System (INIS)

    Simon, R.; Krischer, W.; Price, M.S.T.

    1986-01-01

    The paper presents the aims of quality assurance in the design and production of radioactive waste packages. It lists the most relevant acceptance criteria and regulatory requirements, investigates the institutional and technical problems of carrying out Quality Assurance and presents suggestions for establishing suitable organisational structures and technical programmes to provide adequate confidence in the safe nature and the performance of waste packages. The Commission of European Communities has laid emphasis on the development of appropriate test methods in its last research and development programme. First results of the work are reviewed in the context of international progress in this field. (author)

  10. Assuring quality in narrative analysis.

    Science.gov (United States)

    Bailey, P H

    1996-04-01

    Many nurse-researchers using qualitative strategies have been concerned with assuring quality in their work. The early literature reveals that the concepts of validity and reliability, as understood from the positivist perspective, are somehow inappropriate and inadequate when applied to interpretive research. More recent literature suggests that because of the positivist and interpretive paradigms are epistemologically divergent, the transfer of quality criteria from one perspective to the other is not automatic or even reasonable. The purpose of this article, therefore, is to clarify what the terms quality, trustworthiness, credibility, authenticity, and goodness mean in qualitative research findings. The process of assuring quality, validation, in qualitative research will be discussed within the context of the interpretive method, narrative analysis. A brief review of quality in narrative analysis nursing research will also be presented.

  11. What cost quality assurance

    International Nuclear Information System (INIS)

    Tikkanen, M.W.; Starek, R.; Liddel, P.R.; Grey, R.G.; Peile, R.C.

    1991-01-01

    This paper reports that the increased awareness of global environmental pollution has meant that analytical laboratories are faced with an increasing number of samples to analyze and a greater demand for quality control for their applications. In answer to these demands, more laboratory managers are turning to automation for analytical procedures and automated routines to perform quality control on individual samples. Atomic Absorption analysis, particularly by graphite furnace and hydride generation technique has proved to be adaptable to automated analysis to determine low concentrations of elements such as As, Co, Cd, Hg, Ag, Ba, Cr and Pb. Although highly sensitive, both techniques are time consuming and highly matrix dependent. They may also require extensive sample preparation prior to analysis. Additionally, government imposed methodologies e.g. those used for the USA EPA, Contract Laboratory Program, RCRA and SDWA programs, require very specific time consuming quality control measures

  12. Material quality assurance risk assessment : [summary].

    Science.gov (United States)

    2013-01-01

    With the shift from quality control (QC) of materials and placement techniques : to quality assurance (QA) and acceptance over the years, the role of the Office : of Materials Technology (OMT) has been shifting towards assurance of : material quality...

  13. An approach to total quality assurance

    International Nuclear Information System (INIS)

    Archer, L.G.

    1976-01-01

    Total Quality Assurance must be based on amalgamating three quality functions: effective quality control, competent inspection, and regularly audited Quality Assurance programmes. In applying these functions the fuel supplier must regard each of his sub-contractors as part of his own works and ensure a common policy of motivated Quality Assurance throughout his own works and those of his suppliers. (author)

  14. Software quality assurance | News

    Science.gov (United States)

    Financial Officer Finance Section Office of the Chief Operating Officer Facilities Engineering Services Accelerator Division Accelerator Physics Center Office of the Chief Safety Officer Environment, Safety, Health and Quality Section Office of the Chief Project Officer Office of Project Support Services Office of

  15. Guide to quality assurance

    Energy Technology Data Exchange (ETDEWEB)

    1976-01-01

    This standard provides general guidance on activities and functions covered with the attainment of quality. Basic aspects covered are management objectives, program and planning, principles of control, design, specification, purchasing, manufacturing, production, marketing, servicing, documentation, and review evaluation procedures. Organizational aspects are also referred to in an appendix.

  16. Quality assurance manual: Volume 1

    International Nuclear Information System (INIS)

    Oijala, J.E.

    1988-06-01

    Stanford Linear Accelerator Center (SLAC) is a DOE-supported research facility that carries out experimental and theoretical research in high energy physics and developmental work in new techniques for particle acceleration and experimental instrumentation. The purpose of this manual is to describe SLAC quality assurance policies and practices in various parts of the Laboratory

  17. Technology transfer quality assurance

    International Nuclear Information System (INIS)

    Hood, F.C.

    1991-03-01

    The results of research conducted at Pacific Northwest Laboratory (PNL) for the DOE are regularly transferred from the laboratory to the private sector. The principal focus of PNL is on environmental research and waste management technology; other programs of emphasis include molecular science research. The technology transfer process is predicated on Quality to achieve its objectives effectively. Total quality management (TQM) concepts and principles readily apply to the development and translation of new scientific concepts into commercial products. The concept of technology transfer epitomizes the TQM tenet of continuous improvement: always striving for a better way to do things and always satisfying the customer. A successful technology transfer process adds value to society by providing new or enhanced processes, products, and services to government and commercial customers, with a guarantee of product pedigree and process validity. 2 refs

  18. New techniques in quality assurance

    International Nuclear Information System (INIS)

    Fornicola, J.C.

    1987-01-01

    GPU Nuclear Corp. has a multifaceted quality assurance (QA) program. This program includes a comprehensive QA organization to help ensure its implementation. The QA organization employs various techniques in assuring quality at GPU Nuclear. These techniques not only include the typical QA/quality-control verification activities, i.e., QA engineering, quality control, and audits, but also include some new innovative techniques. Several new techniques have been developed for verifying activities. These techniques include monitoring and functional audits of safety systems. Several new techniques for assessing performance and adequacy and effectiveness of plant and QA programs, such as plant assessments and QA systems engineering evaluations, have also been developed. This paper provides an overview of these and other new techniques being employed by GPU Nuclear's QA organization

  19. Quality assurance in radiation processing

    International Nuclear Information System (INIS)

    Noriah Mod Ali

    2002-01-01

    The growth of the radiation processing industries in Malaysia has presented the SSDL-MINT a new set of parameter for the Quality Assurance (QA) programs. The large massive doses of radiation required for commercial application of sterilization, cross-linking etc needs measurement method outside the scope of familiar radiation detection instruments. This requires establishment of proper calibration procedure and selection of appropriate transfer system/technique to assure adequate traceability to an international radiation standard. The benefit of accurate in-plant dosimetry for the operator, approving authority and purchaser are balanced against the extra dosimetric efforts required for good QA is presented. (Author)

  20. Quality Management, Quality Assurance and Quality Control in Blood Establishments

    OpenAIRE

    Bolbate, N

    2008-01-01

    Quality terms and the roots of the matter are analyzed according to European Committee’s recommendations. Essence of process and product quality control as well as essence of quality assurance is described. Quality system’s structure including quality control, quality assurance and management is justified in the article.

  1. 2. Product quality control and assurance system

    International Nuclear Information System (INIS)

    1990-01-01

    Product quality control and assurance are dealt with in relation to reliability in nuclear power engineering. The topics treated include product quality control in nuclear power engineering, product quality assurance of nuclear power plant equipment, quality assurance programs, classification of selected nuclear power equipment, and standards relating to quality control and assurance and to nuclear power engineering. Particular attention is paid to Czechoslovak and CMEA standards. (P.A.). 2 figs., 1 tab., 12 refs

  2. Quality assurance for hammer forgings

    International Nuclear Information System (INIS)

    Potthast, E.

    1984-01-01

    The quality assurance program introduced by Arbed Saarstahl and laid down in a quality assurance manual is described. A particular attention is attached thereby both to quality practice proper and to a reliable flow of information amongst all the persons involved. The production and test sequence schedules of the hammer forging plant are illustrated by the example of a forged valve housing for nuclear power plants. These schedules specify not only the forging process in the individual production stages but also the workpiece contour after each working operation, the heat treatment, the furnace charging, and the inspection of finished parts. The formalization of the tests is designed both to promote the customer's trust towards the supplier and to prevent the formal operations involved from hindering further technical development. (orig.) [de

  3. Quality assurance in the design

    International Nuclear Information System (INIS)

    Edelmann, J.

    1980-01-01

    System- and product-related quality assurance measures are completing one another. Certainly it is possible to detect a lot of defects in the single technical document by well controlled product related quality inspections and to avoid the consequences of these defects; but also a not unimportant part of defects and deviations has its origin in system linked deficiencies. The latter can be detected more easily and more securely by means of system related reviews (System audit, Product audit). But also the sole implementation of system related quality assurance measures keeps the danger to get stuck only in formality and to loose all references to the specific characteristics of the product. (orig./RW)

  4. Remedial investigation sampling and analysis plan for J-Field, Aberdeen Proving Ground, Maryland: Volume 2, Quality Assurance Project Plan

    Energy Technology Data Exchange (ETDEWEB)

    Prasad, S.; Martino, L.; Patton, T.

    1995-03-01

    J-Field encompasses about 460 acres at the southern end of the Gunpowder Neck Peninsula in the Edgewood Area of APG (Figure 2.1). Since World War II, the Edgewood Area of APG has been used to develop, manufacture, test, and destroy chemical agents and munitions. These materials were destroyed at J-Field by open burning and open detonation (OB/OD). For the purposes of this project, J-Field has been divided into eight geographic areas or facilities that are designated as areas of concern (AOCs): the Toxic Burning Pits (TBP), the White Phosphorus Burning Pits (WPP), the Riot Control Burning Pit (RCP), the Robins Point Demolition Ground (RPDG), the Robins Point Tower Site (RPTS), the South Beach Demolition Ground (SBDG), the South Beach Trench (SBT), and the Prototype Building (PB). The scope of this project is to conduct a remedial investigation/feasibility study (RI/FS) and ecological risk assessment to evaluate the impacts of past disposal activities at the J-Field site. Sampling for the RI will be carried out in three stages (I, II, and III) as detailed in the FSP. A phased approach will be used for the J-Field ecological risk assessment (ERA).

  5. Grid Technology and Quality Assurance

    International Nuclear Information System (INIS)

    Rippa, A.; Manieri, A.; Begin, M.E.; Di Meglio, A.

    2007-01-01

    Grid is one of the potential architectures of the coming years to support both the research and the commercial environment. Quality assurance techniques need both to adapt to these new architectures and exploit them to improve its effectiveness. Software quality is a key issue in the Digital Era: Industries as well as Public Administrations devote time to check and verify the quality of ICT products and services supplied. The definition of automatic measurement of quality metrics is a key point for implementing effective QA methods. In this paper we propose a quality certification model, named Grid-based Quality Certification Model (GQCM), that uses automatically calculable metrics to asses the quality of software applications; this model has been developed within the ETICS SSA4 activities and exploit grid technology for full automation of metrics calculation. It is however designed to be generic enough such that it can be implemented using any automatic build and test tool. (Author)

  6. Quality Assurance In Radioactivity Measurements

    International Nuclear Information System (INIS)

    Riekstina, D.; Veveris, O.; Smilskalne, G.

    2007-01-01

    The credibility of obtained results is ensured by the quality assurance and control. The main requisitions involved in the quality assurance of the laboratory according to the requirements of LVS EN ISO/IEC 17025:2005 are: 1) the use of calibrated equipment only; 2) the regular and long-time use of reference materials in the control of equipment; 3) the estimation of uncertainty sources and determination of uncertainties within the given interval of credibility; 4) the validation and verification. The very important requirement is regular participation in the interlaboratory intercomparison exercises that makes it possible to estimate and find possible error sources and carry out the corrective actions. The measurements of the radioactivity of Cs-137, Co-60, H-3, the natural radioactive nuclides as well as other radionuclides in different environmental (soil, precipitation, different types of water, needles, et al.) samples, and in various radioactive polluted objects are carried out in the Laboratory of Radiation physics. The quality assurance system was implemented in our laboratory in 2000. Since 1999 laboratory is regular participant in the interlaboratory intercomparison exercises, organized by the RISO National Laboratory (Denmark) and IAEA (Vienna). The paper shows the laboratory's system of quality assurance and its implementation. We have the internal quality audit program that takes into account the requirements of LVS EN ISO/IEC 17025: 2005, but the main attention is paid to the intercomparison of the results of analyses of laboratories, their evaluation and interpretation. Only credible and justified results can be the basis for further use in any field, thus making it possible to make legitimate decisions. (Authors)

  7. Quality assurance in tube manufacture

    International Nuclear Information System (INIS)

    Depken, H.

    1976-01-01

    Reliability in service essential for many high-technology products fabricated today. This is particularly the case within the nuclear industry. Here defective materials or components may have diastrous consequences to the safety of human beings and the environment. A new concept - Quality Assurance - originates from this industry. The concept implies that all contractors, fabricators and material manufactures involved must prove that the quality control system used, fulfits particular requirements at all manufacturing, inspection and testing stages. These requirement are laid down in two standards issued by the U.S. Atomic Energy Commission and the American Society of Mechanical Engineers. These standards are discussed in the paper. As a manufacturer of steel products for nuclear applications Sandvik has been forced to establish a quality assurance system according to these principles. The Sandvik approach is briefly described with regard to organisation and other major quality assurance activities. Further the education and training of operators and technicians is touched upon. Finally some viewpoints regarding audits performed by customers of steel manufacturers are expressed. (author)

  8. Characteristics quality system assurance of university programs

    Directory of Open Access Journals (Sweden)

    Lucian Ion Medar

    2011-03-01

    Full Text Available Quality assurance program of study requires time, dedication, effort, innovative thinking and creativity. Competitive research programs monitored by quality assurance system to create the desired results on the relationship between learning and teaching methods and assessment.

  9. Has quality assurance outlived its usefulness

    International Nuclear Information System (INIS)

    Goldenberg, N.

    1989-01-01

    This paper explores the impact that better management and increased productivity will have on the need for, and role of, quality assurance in the future. The author discusses criticisms of existing quality assurance programs

  10. Quality assurance manual: Volume 2, Appendices

    International Nuclear Information System (INIS)

    Oijala, J.E.

    1988-06-01

    This paper contains quality assurance information on departments of the Stanford Linear Accelerator Center. Particular quality assurance policies and standards discussed are on: Mechanical Systems; Klystron and Microwave Department; Electronics Department; Plant Engineering; Accelerator Department; Purchasing; and Experimental Facilities Department

  11. Quality assurance - how to involve the employees

    DEFF Research Database (Denmark)

    Jørgensen, Michael Søgaard

    1996-01-01

    An overview of strategies for involvement of employees in quality assurance developement and implementation.......An overview of strategies for involvement of employees in quality assurance developement and implementation....

  12. Integrating quality assurance and research and development

    International Nuclear Information System (INIS)

    Dronkers, J.J.

    1985-01-01

    Quality assurance programs cannot be transferred from one organization to another without attention to existing cultures and traditions. Introduction of quality assurance programs constitutes a significant change and represents a significant impact on the organizational structure and operational mode. Quality assurance professionals are change agents, but do not know how to be effective ones. Quality assurance as a body of knowledge and experience can only become accepted when its practitioners become familiar with their role as change agents. 8 references

  13. Quality assurance in diagnostic radiology

    International Nuclear Information System (INIS)

    1982-01-01

    The present guide endeavours to provide an outline of the type of quality assurance programme to be recommended for (1) routine implementation by those performing radiodiagnostic procedures (medical radiology technicians, medical physicists, and radiologists), (2) for application by the responsible national authorities, and (3) for use by international bodies such as the International Society of Radiology (ISR), the International Commission on Radiological Protection (ICRP), and the International Commission on Radiation Units and Measurements (ICRU)

  14. Quality assurance of ageing components

    International Nuclear Information System (INIS)

    Novak, W.

    1992-01-01

    Comprehensive and permanent quality assurance on existing plants places very high requirements on measurement and evaluation technology. The necessary preconditions are often not met, however. By means of stocktaking using an external data registration and evaluation system may provide the basis for the assessment of the object and the existing power station instrumentation. After defining the desired scope and standards for the evaluation process, a specific solution may be produced. 5 figs

  15. Quality Assurance Requirements and Description

    International Nuclear Information System (INIS)

    Ram Murthy

    2002-01-01

    The Quality Assurance Requirements and Description (QARD) is the principal Quality Assurance (QA) document for the Civilian Radioactive Waste Management Program (Program). It establishes the minimum requirements for the QA program [INTRODUCTION :1p2s (NOT A REQUIREMENT)]. The QARD contains regulatory requirements and program commitments necessary for the development of an effective QA program [INTRODUCTION :1p3s (NOT A REQUIREMENT)]. Implementing documents must be based on, and be consistent with the QARD. The QARD applies to the following: (1) Acceptance of spent nuclear fuel and high-level waste. (2) Transport of spent nuclear fuel and high-level waste. (3) Storage of spent nuclear fuel through receipt of storage cask certification or a facility operating license. (4) Monitored Geologic Repository, including the site characterization activities [Exploratory Studies Facility (ESF) and surface based testing], through receipt of an operating license. (5) High-level waste form development through qualification, production, and acceptance. (6) Characterization of DOE spent nuclear fuel, and conditioning through acceptance of DOE spent nuclear fuel. Section 2.0, Quality Assurance Program, defines in greater detail criteria for determining work subject to the QARD

  16. Quality assurance in the nuclear industry

    International Nuclear Information System (INIS)

    Knoedler, D.

    1978-01-01

    Quality assurance is the sum of all activities systematically planned, practiced, and controlled with the aim to assure the quality of deliveries and performances. This assurance today covers all phases of activities, from the planning (including a determination of the required and necessary quality characteristics) to the start-up of a plant. (orig./RW) [de

  17. Quality assurance management policies and requirements

    International Nuclear Information System (INIS)

    1985-10-01

    The purpose of this document is to: set forth overall, integrated quality assurance management policies and requirements for the entire Civilian Radioactive Waste Management Program; define management responsibilities for assuring quality; and provide a general framework for the development of more detailed quality assurance management policies and requirements by program, project, and contractor organizations

  18. 40 CFR 31.45 - Quality assurance.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 1 2010-07-01 2010-07-01 false Quality assurance. 31.45 Section 31.45... Requirements Reports, Records, Retention, and Enforcement § 31.45 Quality assurance. If the grantee's project... quality assurance practices consisting of policies, procedures, specifications, standards, and...

  19. 7 CFR 652.7 - Quality assurance.

    Science.gov (United States)

    2010-01-01

    ... 7 Agriculture 6 2010-01-01 2010-01-01 false Quality assurance. 652.7 Section 652.7 Agriculture... assurance. (a) NRCS will review, in consultation with the Farm Service Agency, as appropriate, the quality... information obtained through its quality assurance process, documentation submitted by the technical service...

  20. 30 CFR 74.9 - Quality assurance.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Quality assurance. 74.9 Section 74.9 Mineral... DUST SAMPLING DEVICES Requirements for Continuous Personal Dust Monitors § 74.9 Quality assurance. (a) General requirements. The applicant shall establish and maintain a quality control system that assures...

  1. 40 CFR 30.54 - Quality assurance.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 1 2010-07-01 2010-07-01 false Quality assurance. 30.54 Section 30.54... NON-PROFIT ORGANIZATIONS Post-Award Requirements Reports and Records § 30.54 Quality assurance. If the... data generation, the grantee shall develop and implement quality assurance practices consisting of...

  2. 10 CFR 76.93 - Quality assurance.

    Science.gov (United States)

    2010-01-01

    ... 10 Energy 2 2010-01-01 2010-01-01 false Quality assurance. 76.93 Section 76.93 Energy NUCLEAR REGULATORY COMMISSION (CONTINUED) CERTIFICATION OF GASEOUS DIFFUSION PLANTS Safety § 76.93 Quality assurance. The Corporation shall establish, maintain, and execute a quality assurance program satisfying each of...

  3. Quality assurance of nuclear fuel

    International Nuclear Information System (INIS)

    1994-01-01

    The guide presents the quality assurance requirements to be completed with in the procurement, design, manufacture, transport, handling and operation of the nuclear fuel. The guide also applies to the procurement of the control rods and the shield elements to be placed in the reactor. The guide is mainly aimed for the licensee responsible for the procurement and operation of fuel, for the fuel designer and manufacturer and for other organizations whose activities affect fuel quality, the safety of fuel transport, storage and operation. (2 refs.)

  4. Quality assurance in digital radiography

    International Nuclear Information System (INIS)

    Busch, H.P.; Lehmann, K.J.

    1989-01-01

    At present, there is no standard way of evaluating performance characteristics of digital radiography systems. Continuous measurements of performance parameters are necessary in order to obtain images of high quality. Parameters of quality assurance in digital radiography, which can be evaluated with simple, quick methods, are spatial resolution, low-contrast detectability, dynamic range and exposure dose. Spatial resolution was determined by a lead bar pattern, whereas the other parameters were measured by commercially available phantoms. Performance measurements of 10 digital subtraction angiography (DSA) units and one digital radiography system for unsubtracted digital radiography were assessed. From these results, recommendations for performance parameter levels will be discussed. (author)

  5. Quality assurance techniques for activation analysis

    International Nuclear Information System (INIS)

    Becker, D.A.

    1984-01-01

    The principles and techniques of quality assurance are applied to the measurement method of activation analysis. Quality assurance is defined to include quality control and quality assessment. Plans for quality assurance include consideration of: personnel; facilities; analytical design; sampling and sample preparation; the measurement process; standards; and documentation. Activation analysis concerns include: irradiation; chemical separation; counting/detection; data collection, and analysis; and calibration. Types of standards discussed include calibration materials and quality assessment materials

  6. Quality assurance in radionuclide laboratories

    International Nuclear Information System (INIS)

    Otto, R.; Voelkle, H.; Wershofen, H.; Wilhelm, C.

    2003-01-01

    The authors are members of an ad-hoc working group preparing a contribution to the procedures manual (''Loseblattsammlung'') dealing with quality assurance and quality control in radionuclide laboratories. The Loseblattsammlung is edited by the working group ''Environmental Monitoring'' of the German-Swiss Radiological Protection Association. The intention of the manual under preparation is not to give a procedure on how to establish a quality management system allowing for an accreditation in accordance with the international standard DIN EN ISO/IEC 17025:2000 04 (''ISO 17025'') [1] but to compile routine quality control procedures necessary for reliable measurements and to give tips to the practitioner on how to keep both the extent and the frequency of procedures on a reasonable level. A short version of the Loseblatt is presented here. (orig.)

  7. Is quality assurance really necessary

    International Nuclear Information System (INIS)

    Elwen, L.

    1983-01-01

    The modern concept of quality assurance began to take root in the 50's in Japan. In the rest of the world the demand for quality of products and services might well have arisen through the demise of the craftsman, concurrent with a change in emphasis from quality and workmanship towards economy and output. In the beginning this metamorphosis had its virtues, when rationalisation of production methods benefited both producer and consumer. However, the increasing pressure on production in virtually all sectors of commerce and industry inevitably lead to a trend towards cutting corners, a philosophy not conducive to increasing the standards of quality. The shortage of skilled manpower began to make itself felt at about the same time. The civil construction industry did not remain unscathed

  8. Is quality assurance really necessary

    Energy Technology Data Exchange (ETDEWEB)

    Elwen, L

    1983-03-01

    The modern concept of quality assurance began to take root in the 50's in Japan. In the rest of the world the demand for quality of products and services might well have arisen through the demise of the craftsman, concurrent with a change in emphasis from quality and workmanship towards economy and output. In the beginning this metamorphosis had its virtues, when rationalisation of production methods benefited both producer and consumer. However, the increasing pressure on production in virtually all sectors of commerce and industry inevitably lead to a trend towards cutting corners, a philosophy not conducive to increasing the standards of quality. The shortage of skilled manpower began to make itself felt at about the same time. The civil construction industry did not remain unscathed.

  9. Quality assurance or total quality management

    International Nuclear Information System (INIS)

    Eisl, W.

    1992-01-01

    The globalisation of world trade and the reduction of East West polarisation means that protected markets are disappearing. This is leading to an increase in the ferocity of competition, mainly in large industrialised regions, whereby quality, delivery time, innovation and after-sales service are gaining more and more in significance. This paper is intended to show the deep rooted changes which global competition will bring with it in terms of quality assurance. 7 figs

  10. Quality Assurance for Clinical Trials

    Science.gov (United States)

    Ibbott, Geoffrey S.; Haworth, Annette; Followill, David S.

    2013-01-01

    Cooperative groups, of which the Radiation Therapy Oncology Group is one example, conduct national clinical trials that often involve the use of radiation therapy. In preparation for such a trial, the cooperative group prepares a protocol to define the goals of the trial, the rationale for its design, and the details of the treatment procedure to be followed. The Radiological Physics Center (RPC) is one of several quality assurance (QA) offices that is charged with assuring that participating institutions deliver doses that are clinically consistent and comparable. The RPC does this by conducting a variety of independent audits and credentialing processes. The RPC has compiled data showing that credentialing can help institutions comply with the requirements of a cooperative group clinical protocol. Phantom irradiations have been demonstrated to exercise an institution’s procedures for planning and delivering advanced external beam techniques (1–3). Similarly, RPC data indicate that a rapid review of patient treatment records or planning procedures can improve compliance with clinical trials (4). The experiences of the RPC are presented as examples of the contributions that a national clinical trials QA center can make to cooperative group trials. These experiences illustrate the critical need for comprehensive QA to assure that clinical trials are successful and cost-effective. The RPC is supported by grants CA 10953 and CA 81647 from the National Cancer Institute, NIH, DHHS. PMID:24392352

  11. Quality assurance for gamma knives

    International Nuclear Information System (INIS)

    Jones, E.D.; Banks, W.W.; Fischer, L.E.

    1995-09-01

    This report describes and summarizes the results of a quality assurance (QA) study of the Gamma Knife, a nuclear medical device used for the gamma irradiation of intracranial lesions. Focus was on the physical aspects of QA and did not address issues that are essentially medical, such as patient selection or prescription of dose. A risk-based QA assessment approach was used. Sample programs for quality control and assurance are included. The use of the Gamma Knife was found to conform to existing standards and guidelines concerning radiation safety and quality control of external beam therapies (shielding, safety reviews, radiation surveys, interlock systems, exposure monitoring, good medical physics practices, etc.) and to be compliant with NRC teletherapy regulations. There are, however, current practices for the Gamma Knife not covered by existing, formalized regulations, standards, or guidelines. These practices have been adopted by Gamma Knife users and continue to be developed with further experience. Some of these have appeared in publications or presentations and are slowly finding their way into recommendations of professional organizations

  12. Quality assurance for gamma knives

    Energy Technology Data Exchange (ETDEWEB)

    Jones, E.D.; Banks, W.W.; Fischer, L.E. [Lawrence Livermore National Lab., CA (United States)

    1995-09-01

    This report describes and summarizes the results of a quality assurance (QA) study of the Gamma Knife, a nuclear medical device used for the gamma irradiation of intracranial lesions. Focus was on the physical aspects of QA and did not address issues that are essentially medical, such as patient selection or prescription of dose. A risk-based QA assessment approach was used. Sample programs for quality control and assurance are included. The use of the Gamma Knife was found to conform to existing standards and guidelines concerning radiation safety and quality control of external beam therapies (shielding, safety reviews, radiation surveys, interlock systems, exposure monitoring, good medical physics practices, etc.) and to be compliant with NRC teletherapy regulations. There are, however, current practices for the Gamma Knife not covered by existing, formalized regulations, standards, or guidelines. These practices have been adopted by Gamma Knife users and continue to be developed with further experience. Some of these have appeared in publications or presentations and are slowly finding their way into recommendations of professional organizations.

  13. Digital radiography for quality assurance

    International Nuclear Information System (INIS)

    Thiele, H.; Friemel, H.J.

    2001-01-01

    The digital radiographic system AMICA-401 is described. It is a mobile system originally developed for wall thickness and diameter measurements of insulated and non-insulated pipes which is also suited for quality assurance in fabrication and maintenance. Its advantages are immediate evaluation of images, very short exposure times with reduced radiation loads, and an efficient integrated image processing software. Further, no chemical substances are required for film processing. The system can be used both in mobile and in stationary applications. Practical examples are presented and discussed. (orig.) [de

  14. Mammography quality assurance in Morocco

    International Nuclear Information System (INIS)

    Zaoui, F.; Talsmat, K.; Lalaoui, K.

    2001-01-01

    The 'Centre National de l'Energie, des Sciences et des Techniques Nucleaires' (CNESTEN) realised, from February 1999 to March 2000, a quality control of 41 mammography facilities in Morocco. The protocol and standards adopted for achieving the control of elements constituting the mammography chain are those elaborated by GIM and Qualix association. Statistics and conformities results are presented. The program was performed in order to demonstrate to the practitioners in mammography field, the utility and necessity to have a national quality assurance policy. The main objective of CNESTEN is to be accredited by the Moroccan government as a reference laboratory in quality control and dose evaluation in medical imaging and radiotherapy. To achieve this goal the CNESTEN has set up Medical Physic Unit well trained and equipped with the necessary instruments. (author)

  15. Quality assurance - not only for engineers

    International Nuclear Information System (INIS)

    Treffner, F.W.

    1984-01-01

    The actual purpose of quality assurance is the definition of effective processes, ways and means of planning, fabricating and obtaining the required characteristics determining the quality of components, subsystems and their fabrication techniques at any place and any time. Service companies can contribute quality assurance, quality control and documentation work do cost-benefit analyses and act as expert consultants. (orig.) [de

  16. The challenge of Quality Assurance

    International Nuclear Information System (INIS)

    Simon, R.; Price, M.S.T.; Krischer, W.

    1985-01-01

    The safe terminal containment of hazardous wastes cannot only rely upon the geographic remoteness and the arid climates of the repository sites. Radioactive and permanently toxic chemical wastes must by prevented from returning to the human environment by natural and engineered barriers. The long-term integrity of these barriers and the safety of waste emplacement operation will be controlled by systematic actions under the common objective of Quality Assurance (QA). The following paper presents the aims of QA in the design and production of waste packages. It lists the most relevant acceptance criteria and regulatory requirements, investigates the institutional and technical problems of carrying out Quality Assurance and presents suggestions for establishing suitable organizational structures and technical programmes to provide adequate confidence in the safe nature and the performance of waste packages. In view of the technical difficulties of verifying the compliance of industrially produced waste forms with the acceptance criteria, the CEC has laid emphasis on the development of appropriate test methods in its last R and D programme. First results of the work are reviewed in the context of international progress in this field

  17. Nuclear power plants - Quality assurance

    International Nuclear Information System (INIS)

    1980-01-01

    This International Standard defines principles for the establishment and implementation of quality assurance programmes during all phases of design, procurement, fabrication, construction, commissioning, operation, maintenance and decommissioning of structures, systems and components of nuclear power plants. These principles apply to activities affecting the quality of items, such as designing, purchasing, fabricating, handling, shipping, storing, cleaning, erecting, installing, testing, commissioning, operating, inspecting, maintaining, repairing, refuelling and modifying and eventually decommissioning. The manner in which the principles described in this document will be implemented in different organizations involved in a specific nuclear power project will depend on regulatory and contractual requirements, the form of management applied to a nuclear power project, and the nature and scope of the work to be performed by different organizations

  18. Quality assurance and statistical control

    DEFF Research Database (Denmark)

    Heydorn, K.

    1991-01-01

    In scientific research laboratories it is rarely possible to use quality assurance schemes, developed for large-scale analysis. Instead methods have been developed to control the quality of modest numbers of analytical results by relying on statistical control: Analysis of precision serves...... to detect analytical errors by comparing the a priori precision of the analytical results with the actual variability observed among replicates or duplicates. The method relies on the chi-square distribution to detect excess variability and is quite sensitive even for 5-10 results. Interference control...... serves to detect analytical bias by comparing results obtained by two different analytical methods, each relying on a different detection principle and therefore exhibiting different influence from matrix elements; only 5-10 sets of results are required to establish whether a regression line passes...

  19. Basic principles of quality assurance

    International Nuclear Information System (INIS)

    Stauffer, M.

    1977-01-01

    After a brief review of the origin of the 'quality concept' and the historical development of quality assurance, questions such as 'what is QA' and 'why is QA so important in nuclear technology' as well as definitions and main requirements of relevant QA codes and standards are presented and discussed. By means of a project realization schematic, tasks, duties, responsibilities, and possible QA organigrammes as well as QA programme and manual requirements are explained and compared. From a QA point of view, it is shown that no basic difference exists between design and production or construction control activities. Special emphasis is layed upon active owner's participation in the implementation of QA programmes for NPP and the advantages offered are described and illustrated by typical examples. (RW) [de

  20. Quality assurance programme and quality control

    International Nuclear Information System (INIS)

    Alvarez de Buergo, L.

    1979-01-01

    The paper analyses the requirements for the quality assurance and control in nuclear power plant projects which are needed to achieve safe, reliable and economic plants. The author describes the structure for the establishment of a nuclear programme at the national level and the participation of the different bodies involved in a nuclear power plant project. The paper ends with the study of a specific case in Spain. (NEA) [fr

  1. Software quality assurance - seven years experience

    International Nuclear Information System (INIS)

    Malsbury, J.A.

    1987-01-01

    This paper describes seven years experience with software quality assurance at PPPL. It covers the early attempts of 1980 and 1981 to establish software quality assurance; the first attempt of 1982 to develop a complete software quality assurance plan; the significant modifications of this plan in 1985; and the future. In addition, the paper describes the role of the Quality Assurance organization within each plan. The scope of this paper is limited to discussions of the software development procedures used in the seven year period. Other software quality topics, such as configuration control or problem identification and resolution, are not discussed

  2. Quality assurance and nuclear power plant safety

    International Nuclear Information System (INIS)

    Mullan, J.V.

    1983-01-01

    Quality assurance in the nuclear industry was born in the late 1960s. Atomic Energy Control Board staff began its regulatory practice on quality assurance during that period. In this presentation the author traces the circumstances that first led to the establishment of Canadian nuclear power plant quality assurance programmes, summarizes progress over the last decade and a half, and outlines the current regulatory approach and what has been learned so far

  3. Quality assurance in biomarker measurement.

    Science.gov (United States)

    Aitio, A; Apostoli, P

    1995-05-01

    Quality assurance (QA) concerns the validity of all the analytical processes (from collection of the samples to interpretation of the results). It is not an abstract concept but must be adapted to the different situations such as the different exposure levels, the different analytical methods, and the context of use (risk assessment procedures, research, routine determinations). The main requirements in QA programmes regard the control of all the known sources of preanalytical and analytical variations, while the instruments with which adequate QA can be implemented are the certified materials and the quality control programmes (quality manual, internal and external quality controls). Another important concept in QA is that measurements must be placed a different metrological levels: at the highest there are the methods (definitive, reference) to be used for assessing accuracy of routine methods. QA programmes should enable a grading of biomarkers (from experimental only to full evaluated) and of the laboratories in order to identify the significance of the test and to assess the level at which a laboratory could operate.

  4. Hungary Higher Education Quality Assurance System

    Directory of Open Access Journals (Sweden)

    Che Ru-shan

    2013-07-01

    Full Text Available Higher education quality assurance system has drawn much attention since 1980s. Most countries are committed to build the higher education quality assurance system to meet international standards. Under such an international trend, Hungary also actively promotes higher education reform, and established Hungarian Accreditation Committee and in order to ensure the quality of higher education.

  5. Elements of quality assurance in environmental surveillance

    International Nuclear Information System (INIS)

    Johnson, L.J.

    1975-01-01

    Qualities of an environmental surveillance program requiring control or assurance are reviewed. Requirements of accuracy, reproducibility, sensitivity, acceptability, and time and cost effectiveness are qualities discussed. The controls applicable to sample collection, handling, chemical analysis, measurement and data presentation are identified and discussed as they pertain to environmental monitoring. Quality assurance program recommendations for developing and reporting environmental surveillance data are provided

  6. Quality assurance for image-guided radiotherapy

    International Nuclear Information System (INIS)

    Marinello, Ginette

    2008-01-01

    The topics discussed include, among others, the following: Quality assurance program; Image guided radiotherapy; Commissioning and quality assurance; Check of agreement between visual and displayed scales; quality controls: electronic portal imaging device (EPID), MV-kV and kV-kV, cone-beam CT (CBCT), patient doses. (P.A.)

  7. Quality Assurance in Chinese Higher Education

    Science.gov (United States)

    Li, Yuan

    2010-01-01

    Quality assurance has been integrated into the fabric of higher education in China, with the issue of quality in higher education--how to evaluate it and how to enhance it--now taking centre stage in Chinese higher education. In the past decade, the development of quality assurance in Chinese higher education has covered a broad spectrum of…

  8. Quality assurance program for nuclear power plants

    International Nuclear Information System (INIS)

    Gamon, T.H.

    1976-02-01

    The Topical Report presented establishes and provides the basis for the Brown and Root Quality Assurance Program for Nuclear Power Plants from which the Brown and Root Quality Assurance Manual is prepared and implemented. The Quality Assurance Program is implemented by the Brown and Root Power Division during the design, procurement, and construction phases of nuclear power plants. The Brown and Root Quality Assurance Program conforms to the requirements of Nuclear Regulatory Commission Regulation 10 CFR 50, Appendix B; to approved industry standards such as ANSI N45.2 and ''Daughter Standards''; or to equivalent alternatives as indicated in the appropriate sections of the report

  9. Quality assurance program for nuclear power plants

    International Nuclear Information System (INIS)

    Gamon, T.H.

    1976-06-01

    This topical report establishes and provides the basis for the Brown and Root Quality Assurance Program for Nuclear Power Plants from which the Brown and Root Quality Assurance Manual is prepared and implemented. The Quality Assurance Program is implemented by the Brown and Root Power Division during the design, procurement, and construction phases of nuclear power plants. The Brown and Root Quality Assurance Program conforms to the requirements of Nuclear Regulatory Commission Regulation 10 CFR 50, Appendix B; to approved industry standards such as ANSI N45.2 and ''Daughter Standards''; or to equivalent alternatives as indicated in the appropriate sections of this report

  10. References on EPA Quality Assurance Project Plans

    Science.gov (United States)

    Provides requirements for the conduct of quality management practices, including quality assurance (QA) and quality control (QC) activities, for all environmental data collection and environmental technology programs performed by or for this Agency.

  11. Quality assurance considerations in nuclear waste management

    International Nuclear Information System (INIS)

    Delvin, W.L.

    1982-01-01

    Proper use of quality assurance will provide the basis for an effective management control system for nuclear waste management programs. Control is essential for achieving successful programs free from costly losses and failures and for assuring the public and regulators that the environment and health and safety are being protected. The essence of quality assurance is the conscientious use of planned and systematic actions, based on selecting and applying appropriate requirements from an established quality assurance standard. Developing a quality assurance program consists of using knowledge of the technical and managerial aspects of a project to identify and evaluate risks of loss and failure and then to select appropriate quality assurance requirements that will minimize the risks. Those requirements are integrated into the project planning documents and are carried out as specific actions during the life of the project

  12. Statistical methods for quality assurance

    International Nuclear Information System (INIS)

    Rinne, H.; Mittag, H.J.

    1989-01-01

    This is the first German-language textbook on quality assurance and the fundamental statistical methods that is suitable for private study. The material for this book has been developed from a course of Hagen Open University and is characterized by a particularly careful didactical design which is achieved and supported by numerous illustrations and photographs, more than 100 exercises with complete problem solutions, many fully displayed calculation examples, surveys fostering a comprehensive approach, bibliography with comments. The textbook has an eye to practice and applications, and great care has been taken by the authors to avoid abstraction wherever appropriate, to explain the proper conditions of application of the testing methods described, and to give guidance for suitable interpretation of results. The testing methods explained also include latest developments and research results in order to foster their adoption in practice. (orig.) [de

  13. Quality assurance in tissue banking

    International Nuclear Information System (INIS)

    Von Versen, R.; Mnig, H. J.; Bettin, D.

    1999-01-01

    Today the different kinds of human allografts have the full acceptance for the clinical application for the treatment of a very wide range of indications in many medical disciplines. An essential aspect of this acceptance of these allografts is the complete biological safety, first of all the exclusion of virus contaminations. The German Institute for Cell and Tissue Replacement (DIZG) is functioning as a national tissue bank cooperating with more than 300 hospitals in Germany and Austria. Its profile is determined by the processing of tissue allografts like cortical and cancellous bone, fascia lata, tendon as well as skin, skin substitutes and cultured autologous and allogenic kerytinocytes. DIZG is licensed by the German Federal Institute for Pharmaceuticals and Medical Products and the country health authorities. To ensure that the allografts fulfill the highest quality requirements a controlled and certified quality management system has been established. In accordance with the Good Manufacturing Practice all procedures are perform-ned on the basis of validated methods. All non-vital allografts are sterilized by a chemical sterilisation method with peracetic acid (PAA) that is validated by the Robert Koch Institute, an independent governmental institution, for the inactivation of bacteria, fungi and viruses. The used test viruses are Pseudorabies V, Polio V, Bovine Virusdiarrhoe V, Parvo V, Hepatitis A V, HIV). The DIZG quality management system (QMS) is based on ISO 9001 which is required for institutions that are involved in processing, research and education and is certified by an international auditing body. With this presentation the validation design shall be introduced and the responsibility of regional and national tissue banks for internal and external quality control and quality assurance shall be discussed

  14. A conceptual competitive intelligence quality assurance model

    Directory of Open Access Journals (Sweden)

    Tshilidzi Eric Nenzhelele

    2015-12-01

    Full Text Available Competitive Intelligence (CI improves the quality of product and service, decision-making and it improves quality of life. However, it has been established that decision makers are not happy about the quality of CI. This is because enterprises fail in quality assurance of CI. It has been concluded that most enterprises are clueless concerning CI quality assurance. Studies that previously attempted to resolve CI quality problem were limited in scope and focused too much on the quality of information than the overall CI quality. The purpose of this study is to propose a conceptual CI quality assurance model which will help in quality assurance of CI. The research was qualitative in nature and used content analysis.

  15. [Quality assurance in human genetic testing].

    Science.gov (United States)

    Stuhrmann-Spangenberg, Manfred

    2015-02-01

    Advances in technical developments of genetic diagnostics for more than 50 years, as well as the fact that human genetic testing is usually performed only once in a lifetime, with additional impact for blood relatives, are determining the extraordinary importance of quality assurance in human genetic testing. Abidance of laws, directives, and guidelines plays a major role. This article aims to present the major laws, directives, and guidelines with respect to quality assurance of human genetic testing, paying careful attention to internal and external quality assurance. The information on quality assurance of human genetic testing was obtained through a web-based search of the web pages that are referred to in this article. Further information was retrieved from publications in the German Society of Human Genetics and through a PubMed-search using term quality + assurance + genetic + diagnostics. The most important laws, directives, and guidelines for quality assurance of human genetic testing are the gene diagnostics law (GenDG), the directive of the Federal Medical Council for quality control of clinical laboratory analysis (RiliBÄK), and the S2K guideline for human genetic diagnostics and counselling. In addition, voluntary accreditation under DIN EN ISO 15189:2013 offers a most recommended contribution towards quality assurance of human genetic testing. Legal restraints on quality assurance of human genetic testing as mentioned in § 5 GenDG are fulfilled once RiliBÄK requirements are followed.

  16. Regulatory viewpoint on nuclear fuel quality assurance

    International Nuclear Information System (INIS)

    Tripp, L.E.

    1976-01-01

    Considerations of the importance of fuel quality and performance to nuclear safety, ''as low reasonably achievable'' release of radioactive materials in reactor effluents, and past fuel performance problems demonstrate the need for strong regulatory input, review and inspection of nuclear fuel quality assurance programs at all levels. Such a regulatory program is being applied in the United States of America by the US Nuclear Regulatory Commission. Quality assurance requirements are contained within government regulations. Guidance on acceptable methods of implementing portions of the quality assurance program is contained within Regulatory Guides and other NRC documents. Fuel supplier quality assurance program descriptions are reviewed as a part of the reactor licensing process. Inspections of reactor licensee control of their fuel vendors as well as direct inspections of fuel vendor quality assurance programs are conducted on a regularly scheduled basis. (author)

  17. Quality assurance program plan for Building 324

    International Nuclear Information System (INIS)

    Tanke, J.M.

    1997-01-01

    This Quality Assurance Program Plan (QAPP) provides an overview of the quality assurance program for Building 324. This plan supersedes the PNNL Nuclear Facilities Quality Management System Description, PNL-NF-QMSD, Revision 2, dated March 1996. The program applies to the facility safety structures, systems, and components and to activities that could affect safety structures, systems, and components. Adherence to the quality assurance program ensures the following: US Department of Energy missions and objectives are effectively accomplished; Products and services are safe, reliable, and meet or exceed the requirements and expectations of the user; Hazards to the public, to Hanford Site and facility workers, and to the environment are minimized. The format of this Quality Assurance Program Plan is structured to parallel that of 10 CFR 83 0.120, Quality Assurance Requirements

  18. 40 CFR 194.22 - Quality assurance.

    Science.gov (United States)

    2010-07-01

    ... General Requirements § 194.22 Quality assurance. (a)(1) As soon as practicable after April 9, 1996, the Department shall adhere to a quality assurance program that implements the requirements of ASME NQA-1-1989... elicitation used to support applications for certification or re-certification of compliance; (vi) Design of...

  19. Quality assurance manual: Volume 2, Appendices

    Energy Technology Data Exchange (ETDEWEB)

    Oijala, J.E.

    1988-06-01

    This paper contains quality assurance information on departments of the Stanford Linear Accelerator Center. Particular quality assurance policies and standards discussed are on: Mechanical Systems; Klystron and Microwave Department; Electronics Department; Plant Engineering; Accelerator Department; Purchasing; and Experimental Facilities Department. (LSP)

  20. Commissioning quality assurance at Pickering NGS

    International Nuclear Information System (INIS)

    Wieckowski, J.T.

    1983-05-01

    Ontario Hydro decided in 1978 to implement a formal quality assurance program applicable to commissioning and operation of nuclear generating stations. Pickering NGS is the first station to have the commissioning quality assurance (CQA) program applied to it. This paper outlines the scope, implementation, and evaluation of the CQA program as applied to Pickering Unit 5

  1. 30 CFR 7.7 - Quality assurance.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Quality assurance. 7.7 Section 7.7 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR TESTING, EVALUATION, AND APPROVAL OF MINING PRODUCTS TESTING BY APPLICANT OR THIRD PARTY General § 7.7 Quality assurance. Applicants granted...

  2. Ontario's Quality Assurance Framework: A Critical Response

    Science.gov (United States)

    Heap, James

    2013-01-01

    Ontario's Quality Assurance Framework (QAF) is reviewed and found not to meet all five criteria proposed for a strong quality assurance system focused on student learning. The QAF requires a statement of student learning outcomes and a method and means of assessing those outcomes, but it does not require that data on achievement of intended…

  3. 48 CFR 2453.246 - Quality Assurance.

    Science.gov (United States)

    2010-10-01

    ... 48 Federal Acquisition Regulations System 6 2010-10-01 2010-10-01 true Quality Assurance. 2453.246 Section 2453.246 Federal Acquisition Regulations System DEPARTMENT OF HOUSING AND URBAN DEVELOPMENT CLAUSES AND FORMS FORMS Prescription of Forms 2453.246 Quality Assurance. ...

  4. 30 CFR 15.8 - Quality assurance.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Quality assurance. 15.8 Section 15.8 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR TESTING, EVALUATION, AND APPROVAL OF... § 15.8 Quality assurance. (a) Applicants granted an approval or an extension of approval under this...

  5. Quality Assurance in Sub-Saharan Africa

    Science.gov (United States)

    Materu, Peter; Righetti, Petra

    2010-01-01

    This article assesses the status and practice of higher education quality assurance in sub-Saharan Africa, focusing on degree-granting tertiary institutions. A main finding is that structured national-level quality assurance processes in African higher education are a very recent phenomenon and that most countries face major capacity constraints.…

  6. The Concepts of Quality, Quality Assurance and Quality Enhancement

    Science.gov (United States)

    Elassy, Noha

    2015-01-01

    Purpose: This paper aims to critically review and discuss different definitions of the concepts of quality, quality assurance (QA) and quality enhancement (QE) in higher education (HE) with presenting critical perspectives of the literature. Design/methodology/approach: The paper looks at literature concerns with the meaning of quality, QA and QE,…

  7. Reinforcing Quality Assurance in Romanian Higher Education

    Directory of Open Access Journals (Sweden)

    Ana-Maria Dima

    2010-07-01

    Full Text Available Since 1993, the quality assurance system in Romania has gained considerable experience. This experience was recently recognized in 2008 by the ENQA: European Association for Quality Assurance in Higher Education through the admission of ARACIS as a full member of EQAR: the European Quality Assurance Register. The Board of ENQA agreed to grant ARACIS’s full membership of ENQA for five years from 2 June 2009. This article explores the benefits of membership for the Romanian Agency for Quality Assurance in Higher Education – ARACIS, comparing to other regional and global quality assurance agencies networks. The common features and differences between ARACIS and other European agencies are questioned through the frameworks of ENQA and INQAAHE as a case study.

  8. Quality Assurance Planning for Region 9

    Science.gov (United States)

    The ultimate success of an environmental program or project depends on the quality of the environmental data collected and used in decision-making. EPA has developed guidances to help state and tribal governments develop Quality Assurance Program Plans.

  9. National Program of Quality Assurance in Radiotherapy in Cuba

    International Nuclear Information System (INIS)

    Alonso Samper, J. L.; Dominguez Hung, L.; Morales Lopez, J. L.; Alfonso Laguardia, R.; Garcia Yip, F.

    2001-01-01

    It tries on the establishment of a Quality Assurance Nacional System, a Quality Assurance Committee implemented in Cuba, and a Quality Auditory National Program implemented in Cuba to control and assure radiotherapy quality

  10. Printed Circuit Board Quality Assurance

    Science.gov (United States)

    Sood, Bhanu

    2016-01-01

    PCB Assurance Summary: PCB assurance actives are informed by risk in context of the Project. Lessons are being applied across Projects for continuous improvements. Newer component technologies, smaller/high pitch devices: tighter and more demanding PCB designs: Identifying new research areas. New materials, designs, structures and test methods.

  11. Training, Quality Assurance Factors, and Tools Investigation: a Work Report and Suggestions on Software Quality Assurance

    Science.gov (United States)

    Lee, Pen-Nan

    1991-01-01

    Previously, several research tasks have been conducted, some observations were obtained, and several possible suggestions have been contemplated involving software quality assurance engineering at NASA Johnson. These research tasks are briefly described. Also, a brief discussion is given on the role of software quality assurance in software engineering along with some observations and suggestions. A brief discussion on a training program for software quality assurance engineers is provided. A list of assurance factors as well as quality factors are also included. Finally, a process model which can be used for searching and collecting software quality assurance tools is presented.

  12. Tritium systems test assembly quality assurance program

    International Nuclear Information System (INIS)

    Kerstiens, F.L.; Wilhelm, R.C.

    1986-07-01

    A quality assurance program should establish the planned and systematic actions necessary to provide adequate confidence that fusion facilities and their subsystems will perform satisfactorily in service. The Tritium Systems Test Assembly (TSTA) Quality Assurance Program has been designed to assure that the designs, tests, data, and interpretive reports developed at TSTA are valid, accurate, and consistent with formally specified procedures and reviews. The quality consideration in all TSTA activities is directed toward the early detection of quality problems, coupled with timely and positive disposition and corrective action

  13. SWiFT Software Quality Assurance Plan.

    Energy Technology Data Exchange (ETDEWEB)

    Berg, Jonathan Charles [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)

    2016-01-01

    This document describes the software development practice areas and processes which contribute to the ability of SWiFT software developers to provide quality software. These processes are designed to satisfy the requirements set forth by the Sandia Software Quality Assurance Program (SSQAP). APPROVALS SWiFT Software Quality Assurance Plan (SAND2016-0765) approved by: Department Manager SWiFT Site Lead Dave Minster (6121) Date Jonathan White (6121) Date SWiFT Controls Engineer Jonathan Berg (6121) Date CHANGE HISTORY Issue Date Originator(s) Description A 2016/01/27 Jon Berg (06121) Initial release of the SWiFT Software Quality Assurance Plan

  14. Quality assurance for fittings considering nuclear technology

    International Nuclear Information System (INIS)

    Kilian, H.J.

    1987-01-01

    Negative experience made during World War II led to the idea of quality assurance being born in the United States. Thoroughly misunderstood, it came to be incorporated in European mechanical engineering. Quality assurance there was initially considered to be a new term for the oganizational combination of all parts of an enterprise dealing with testing. German manufacturers of heavy-duty and safety fittings represented in the international market were compelled at a relatively early date to properly understand and realize a quality assurance programme. But the multi-fariousness of specifications to be applied and great number of the most different parts made eminent demands on the suitability and variability of the products developed. On the basis of 18 quality criteria the article describes the structure of 'quality' and what its consequences are for an effective quality assurance system - suited for all kinds of specifications. (orig.) [de

  15. Improving patient safety through quality assurance.

    Science.gov (United States)

    Raab, Stephen S

    2006-05-01

    Anatomic pathology laboratories use several quality assurance tools to detect errors and to improve patient safety. To review some of the anatomic pathology laboratory patient safety quality assurance practices. Different standards and measures in anatomic pathology quality assurance and patient safety were reviewed. Frequency of anatomic pathology laboratory error, variability in the use of specific quality assurance practices, and use of data for error reduction initiatives. Anatomic pathology error frequencies vary according to the detection method used. Based on secondary review, a College of American Pathologists Q-Probes study showed that the mean laboratory error frequency was 6.7%. A College of American Pathologists Q-Tracks study measuring frozen section discrepancy found that laboratories improved the longer they monitored and shared data. There is a lack of standardization across laboratories even for governmentally mandated quality assurance practices, such as cytologic-histologic correlation. The National Institutes of Health funded a consortium of laboratories to benchmark laboratory error frequencies, perform root cause analysis, and design error reduction initiatives, using quality assurance data. Based on the cytologic-histologic correlation process, these laboratories found an aggregate nongynecologic error frequency of 10.8%. Based on gynecologic error data, the laboratory at my institution used Toyota production system processes to lower gynecologic error frequencies and to improve Papanicolaou test metrics. Laboratory quality assurance practices have been used to track error rates, and laboratories are starting to use these data for error reduction initiatives.

  16. Quality assurance programme for isotope diagnostic laboratories

    International Nuclear Information System (INIS)

    Krasznai, Istvan

    1987-01-01

    Quality assurance systems are suggested to be introduced in laboratories, in accordance with the recommendations of IAEA and WHO, taking local circumstances into consideration. It is emphasized that a quantitative enhancement of work must not endanger its quality; diagnostic information must be undistorted, reproducible, and gathered with the minimum of radiation burden. National authorities are requested to strengthen their supervision. Recommendations for quality assurance methods are given for medical isotope diagnostic laboratories. (author)

  17. Quality assurance plan, Westinghouse Water Reactor Divisions

    Energy Technology Data Exchange (ETDEWEB)

    1976-03-01

    The Quality Assurance Program used by Westinghouse Nuclear Energy Systems Water Reactor Divisions is described. The purpose of the program is to assure that the design, materials, and workmanship on Nuclear Steam Supply System (NSSS) equipment meet applicable safety requirements, fulfill the requirements of the contracts with the applicants, and satisfy the applicable codes, standards, and regulatory requirements.

  18. Quality assurance in nuclear power plant

    International Nuclear Information System (INIS)

    Magalhaes, M.T. de

    1981-01-01

    The factors related to the licensing procedures of a nuclear power plant (quality assurance and safety analysis) are presented and discussed. The consequences of inadequate attitudes towards these factors are shown and suggestions to assure the safety of nuclear power plants in Brazil are presented. (E.G.) [pt

  19. Quality assurance systems at SKODA JS

    International Nuclear Information System (INIS)

    Janecek, P.

    2000-01-01

    In addition to technical requirements put upon the design, manufacture, installation and commissioning of equipment for nuclear power plants, emphasis is laid upon quality assurance of such activities so as to secure nuclear safety of installations over the world. As the technical level of nuclear safety assurance is being enhanced continuously, the requirements are becoming more and more stringent, which is mirrored by the relevant standards and legislation. SKODA JS has always been pursuing the quality goal and has been contributing to this aspect markedly. The quality assurance system at SKODA JS helps the company to satisfy all the appropriate requirements of its customers as well as the applicable standards and regulations. (author)

  20. Quality assurance - the key to the future

    Energy Technology Data Exchange (ETDEWEB)

    Rix, C [British Coal Corporation, London (UK)

    1992-05-01

    Quality assurance seeks to achieve diligence and attention to detail, which can have substantial effects including reduced costs and improved performance, as well as greater customer satisfaction. British Coal has a policy of quality assurance to BS5750 at all collieries and despatch points, to help maintain its competitive position, to respond to customer requirements, and to continue the drive for reduced costs. A pilot exercise was undertaken at Maltby and Kellingley collieries, and at Oxcroft and Gwaun-cae-Gurwen opencast despatch points, in order to gain sufficient experience to allow rapid implementation of quality assurance at all sites.

  1. Guidelines for comprehensive quality assurance in brachytherapy

    International Nuclear Information System (INIS)

    Goldson, A.L.; Nibhanupudy, J.R.

    1984-01-01

    Brachytherapy treatment techniques can provide significant improvement in local control and overall survival, but only when quality assurance can be guaranteed. To establish brachytherapy quality assurance, basic requirements for three predetermined subdivisions of clinical institutions will be forwarded. These are: (1) centers having minimum requirements to provide brachytherapy, (2) intermediate centers such as regional or community hospitals, and (3) optimal centers such as university hospital and cancer centers. This presentation will highlight personnel needs, equipment requirements, academic activities, clinical experience with these systems and proposed quality assurance guidelines

  2. Commissioning quality assurance for nuclear power plants

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1986-09-01

    This standard contains the requirements for the quality assurance program applicable to the commissioning phase of a nuclear power plant. This standard embodies the relevant quality assurance requirements of CSA Standard CAN3-N286.0, and is the governing Standard for commissioning quality assurance activities in the event of any conflicting requirements. This Standard applies to the commissioning of safety-related equipment, systems, and structures as identified by the owner. It may be applied to other equipment, systems, and structures at the discretion of the owner. 1 fig.

  3. A Quality Assurance Program for decommissioning

    International Nuclear Information System (INIS)

    Briggs, P.M.

    1986-01-01

    Defining the Quality Assurance Program for the US Department of Energy Shippingport Station Decommissioning Project (SSDP) was a unique opportunity because this is the first full-sized commercial nuclear power plant to be decommissioned. General Electric Company defined a Quality Assurance Program that provided adequate control, yet was stripped down to the essentials. The Program is designed to provide a flexible degree of monitoring of subcontractor work, built around a core of radiation safety monitoring, detailed planning, inspection and auditing, and operated with a minimum of dedicated personnel. This paper will concentrate on the traditional quality assurance activities, leaving radiation and environmental monitoring for other presentations

  4. Quality assurance organization of the plant owner

    International Nuclear Information System (INIS)

    Staebler, K.

    1980-01-01

    It is not the primary task of the plant owner to assure the quality during erection. It is, however, his responsibility to check the quality assurance system established by the plant, the supplier and the subcontractor. In the lecture, it is shown that the plant owners do this control in the best efficient way. The special consideration of the plant owner in deciding questions of quality assurance is demonstrated by special examples. The meaning of basic safety for the plant owner is presented. (orig./RW)

  5. Commissioning quality assurance for nuclear power plants

    International Nuclear Information System (INIS)

    1986-09-01

    This standard contains the requirements for the quality assurance program applicable to the commissioning phase of a nuclear power plant. This standard embodies the relevant quality assurance requirements of CSA Standard CAN3-N286.0, and is the governing Standard for commissioning quality assurance activities in the event of any conflicting requirements. This Standard applies to the commissioning of safety-related equipment, systems, and structures as identified by the owner. It may be applied to other equipment, systems, and structures at the discretion of the owner. 1 fig

  6. Quality assurance and demolition: 2006 symposium

    International Nuclear Information System (INIS)

    Thierfeldt, S.

    2006-01-01

    The '2006 Symposium: Quality Assurance and Demolition' jointly organized by compra GmbH and Brenk Systemplanung GmbH this year again focused on quality assurance and the demolition of nuclear facilities as its main topics. The papers presented ranged from issues of clearance and disposal to demolition technologies and status reports about specific demolition projects. The sixteen presentations at the '2006 Symposium: Quality Assurance and Demolition' offered an interesting and very topical cross section of decommissioning and demolition of nuclear facilities in Germany. In 2007, the conference about similar main topics will again be held at the Schloss Bensberg Grand Hotel. (orig.)

  7. Principles and Practices for Quality Assurance and Quality Control

    Science.gov (United States)

    Jones, Berwyn E.

    1999-01-01

    Quality assurance and quality control are vital parts of highway runoff water-quality monitoring projects. To be effective, project quality assurance must address all aspects of the project, including project management responsibilities and resources, data quality objectives, sampling and analysis plans, data-collection protocols, data quality-control plans, data-assessment procedures and requirements, and project outputs. Quality control ensures that the data quality objectives are achieved as planned. The historical development and current state of the art of quality assurance and quality control concepts described in this report can be applied to evaluation of data from prior projects.

  8. Software Quality Assurance activities of ITER CODAC

    Energy Technology Data Exchange (ETDEWEB)

    Pande, Sopan, E-mail: sopan.pande@iter.org [ITER Organization, Route de Vinon sur Verdon, 13115 St Paul Lez Durance (France); DiMaio, Franck; Kim, Changseung; Kim, Joohan; Klotz, Wolf-Dieter; Makijarvi, Petri; Stepanov, Denis; Wallander, Anders [ITER Organization, Route de Vinon sur Verdon, 13115 St Paul Lez Durance (France)

    2013-10-15

    Highlights: ► Comprehensive and consistent software engineering and quality assurance of CODAC. ► Applicable to all CODAC software projects executed by ITER DAs and contractors. ► Configurable plans for cost effective application of SQA processes. ► CODAC software plans SQAP, SVVP, SDP, and SCMP. ► CODAC software processes based on IEEE 12207-2008. -- Abstract: Software as an integral part of the plant system I and C is crucial in the manufacturing and integrated operation of ITER plant systems. Software Quality Assurance is necessary to ensure the development and maintenance of consistently high quality I and C software throughout the lifetime of ITER. CODAC decided to follow IEEE 12207-2008 software lifecycle processes for Software Engineering and Software Quality Assurance. Software Development Plan, Software Configuration Management Plan and Software Verification and Validation Plan are the mainstay of Software Quality Assurance which is documented in the Software Quality Assurance Plan. This paper describes the Software Quality Assurance (SQA) activities performed by CODAC. The SQA includes development and maintenance of above plans, processes and resources. With the help of Verification and Validation Teams they gather evidence of process conformance and product conformance, and record process data for quality audits and perform process improvements.

  9. Software Quality Assurance activities of ITER CODAC

    International Nuclear Information System (INIS)

    Pande, Sopan; DiMaio, Franck; Kim, Changseung; Kim, Joohan; Klotz, Wolf-Dieter; Makijarvi, Petri; Stepanov, Denis; Wallander, Anders

    2013-01-01

    Highlights: ► Comprehensive and consistent software engineering and quality assurance of CODAC. ► Applicable to all CODAC software projects executed by ITER DAs and contractors. ► Configurable plans for cost effective application of SQA processes. ► CODAC software plans SQAP, SVVP, SDP, and SCMP. ► CODAC software processes based on IEEE 12207-2008. -- Abstract: Software as an integral part of the plant system I and C is crucial in the manufacturing and integrated operation of ITER plant systems. Software Quality Assurance is necessary to ensure the development and maintenance of consistently high quality I and C software throughout the lifetime of ITER. CODAC decided to follow IEEE 12207-2008 software lifecycle processes for Software Engineering and Software Quality Assurance. Software Development Plan, Software Configuration Management Plan and Software Verification and Validation Plan are the mainstay of Software Quality Assurance which is documented in the Software Quality Assurance Plan. This paper describes the Software Quality Assurance (SQA) activities performed by CODAC. The SQA includes development and maintenance of above plans, processes and resources. With the help of Verification and Validation Teams they gather evidence of process conformance and product conformance, and record process data for quality audits and perform process improvements

  10. Manpower requirements for quality assurance during operation

    International Nuclear Information System (INIS)

    Pratt, J.M.; Sollenberger, L.G.

    1982-01-01

    As a result of the Three Mile Island accident and the findings presented in various investigatory reports, some fundamental changes are taking place in the role and scope of quality assurance. Recent changes to United States national codes, guides and standards are analysed in order to identify the principles involved. This analysis shows that the scope of the programme is being extended beyond the equipment designated 'nuclear safety related' and greater emphasis is being placed upon the independent verification of the satisfactory performance of activities affecting safety. Such fundamental changes could lead to a significant increase in the number of quality assurance personnel required to support an operating nuclear power plant. The evolving quality assurance organization at Three Mile Island is used to illustrate how these fundamental changes could affect the quality assurance organization and manpower requirements. (author)

  11. Quality assurance terms and definitions - approved 1973

    International Nuclear Information System (INIS)

    Anon.

    1975-01-01

    Standards for certain terms and their definitions that are important to the uniform understanding of the intent of required quality assurance practices for the construction of nuclear power plants are presented

  12. Maintenance quality assurance peer exchange 2.

    Science.gov (United States)

    2009-04-01

    This report documents a comprehensive study of twenty three maintenance quality assurance : (MQA) programs throughout the United States and Canada. The policies and standards of : each program were synthesized to create a general assessment on the co...

  13. Design quality assurance for nuclear power plants

    International Nuclear Information System (INIS)

    1986-07-01

    This Standard contains the requirements for the quality assurance program applicable to the design phase of a nuclear plant, and is applicable to the design of safety-related equipment, systems, and structures, as identified by the owner. 1 fig

  14. Quality Assurance Project Plan Development Tool

    Science.gov (United States)

    This tool contains information designed to assist in developing a Quality Assurance (QA) Project Plan that meets EPA requirements for projects that involve surface or groundwater monitoring and/or the collection and analysis of water samples.

  15. Achieving quality assurance in the Indian programme

    International Nuclear Information System (INIS)

    Challappa, S.; Alekal, R.S.; Murthy, G.S.K.; Palaniappan, M.

    1984-01-01

    Much of the equipment for India's diverse nuclear programme has come from the central workshops of the Bhabha Atomic Research Centre near Bombay. Engineers from the central workshops describe how quality assurance has been put into practice. (author)

  16. Design quality assurance for nuclear power plants

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1986-07-01

    This Standard contains the requirements for the quality assurance program applicable to the design phase of a nuclear plant, and is applicable to the design of safety-related equipment, systems, and structures, as identified by the owner. 1 fig.

  17. Internal quality assurance reviews: challenges and processes ...

    African Journals Online (AJOL)

    Internal quality assurance reviews: challenges and processes – Walter Sisulu University\\'s Business, Management Sciences and Law Faculty. ... This article examines some of the challenges and processes followed by six of the departments ...

  18. Quality assurance in performance assessments

    International Nuclear Information System (INIS)

    Maul, P.R.; Watkins, B.M.; Salter, P.; Mcleod, R

    1999-01-01

    Following publication of the Site-94 report, SKI wishes to review how Quality Assurance (QA) issues could be treated in future work both in undertaking their own Performance Assessment (PA) calculations and in scrutinising documents supplied by SKB (on planning a repository for spent fuels in Sweden). The aim of this report is to identify the key QA issues and to outline the nature and content of a QA plan which would be suitable for SKI, bearing in mind the requirements and recommendations of relevant standards. Emphasis is on issues which are specific to Performance Assessments for deep repositories for radioactive wastes, but consideration is also given to issues which need to be addressed in all large projects. Given the long time over which the performance of a deep repository system must be evaluated, the demonstration that a repository is likely to perform satisfactorily relies on the use of computer-generated model predictions of system performance. This raises particular QA issues which are generally not encountered in other technical areas (for instance, power station operations). The traceability of the arguments used is a key QA issue, as are conceptual model uncertainty, and code verification and validation; these were all included in the consideration of overall uncertainties in the Site-94 project. Additionally, issues which are particularly relevant to SKI include: How QA in a PA fits in with the general QA procedures of the organisation undertaking the work. The relationship between QA as applied by the regulator and the implementor of a repository development programme. Section 2 introduces the discussion of these issues by reviewing the standards and guidance which are available from national and international organisations. This is followed in Section 3 by a review of specific issues which arise from the Site-94 exercise. An outline procedure for managing QA issues in SKI is put forward as a basis for discussion in Section 4. It is hoped that

  19. Quality assurance in performance assessments

    Energy Technology Data Exchange (ETDEWEB)

    Maul, P.R.; Watkins, B.M.; Salter, P.; Mcleod, R [QuantiSci Ltd, Henley-on-Thames (United Kingdom)

    1999-01-01

    Following publication of the Site-94 report, SKI wishes to review how Quality Assurance (QA) issues could be treated in future work both in undertaking their own Performance Assessment (PA) calculations and in scrutinising documents supplied by SKB (on planning a repository for spent fuels in Sweden). The aim of this report is to identify the key QA issues and to outline the nature and content of a QA plan which would be suitable for SKI, bearing in mind the requirements and recommendations of relevant standards. Emphasis is on issues which are specific to Performance Assessments for deep repositories for radioactive wastes, but consideration is also given to issues which need to be addressed in all large projects. Given the long time over which the performance of a deep repository system must be evaluated, the demonstration that a repository is likely to perform satisfactorily relies on the use of computer-generated model predictions of system performance. This raises particular QA issues which are generally not encountered in other technical areas (for instance, power station operations). The traceability of the arguments used is a key QA issue, as are conceptual model uncertainty, and code verification and validation; these were all included in the consideration of overall uncertainties in the Site-94 project. Additionally, issues which are particularly relevant to SKI include: How QA in a PA fits in with the general QA procedures of the organisation undertaking the work. The relationship between QA as applied by the regulator and the implementor of a repository development programme. Section 2 introduces the discussion of these issues by reviewing the standards and guidance which are available from national and international organisations. This is followed in Section 3 by a review of specific issues which arise from the Site-94 exercise. An outline procedure for managing QA issues in SKI is put forward as a basis for discussion in Section 4. It is hoped that

  20. Automating linear accelerator quality assurance.

    Science.gov (United States)

    Eckhause, Tobias; Al-Hallaq, Hania; Ritter, Timothy; DeMarco, John; Farrey, Karl; Pawlicki, Todd; Kim, Gwe-Ya; Popple, Richard; Sharma, Vijeshwar; Perez, Mario; Park, SungYong; Booth, Jeremy T; Thorwarth, Ryan; Moran, Jean M

    2015-10-01

    The purpose of this study was 2-fold. One purpose was to develop an automated, streamlined quality assurance (QA) program for use by multiple centers. The second purpose was to evaluate machine performance over time for multiple centers using linear accelerator (Linac) log files and electronic portal images. The authors sought to evaluate variations in Linac performance to establish as a reference for other centers. The authors developed analytical software tools for a QA program using both log files and electronic portal imaging device (EPID) measurements. The first tool is a general analysis tool which can read and visually represent data in the log file. This tool, which can be used to automatically analyze patient treatment or QA log files, examines the files for Linac deviations which exceed thresholds. The second set of tools consists of a test suite of QA fields, a standard phantom, and software to collect information from the log files on deviations from the expected values. The test suite was designed to focus on the mechanical tests of the Linac to include jaw, MLC, and collimator positions during static, IMRT, and volumetric modulated arc therapy delivery. A consortium of eight institutions delivered the test suite at monthly or weekly intervals on each Linac using a standard phantom. The behavior of various components was analyzed for eight TrueBeam Linacs. For the EPID and trajectory log file analysis, all observed deviations which exceeded established thresholds for Linac behavior resulted in a beam hold off. In the absence of an interlock-triggering event, the maximum observed log file deviations between the expected and actual component positions (such as MLC leaves) varied from less than 1% to 26% of published tolerance thresholds. The maximum and standard deviations of the variations due to gantry sag, collimator angle, jaw position, and MLC positions are presented. Gantry sag among Linacs was 0.336 ± 0.072 mm. The standard deviation in MLC

  1. Linear accelerator quality assurance using EPIQA software

    International Nuclear Information System (INIS)

    Bozhikov, S.; Sokerov, H.; Tonev, A.; Ivanova, K.

    2012-01-01

    Unlike treatment with static fields, using a dynamic multileaf collimator (dMLC), there are significant dosimetric issues which must be assessed before dynamic therapy can be implemented. The advanced techniques require some additional commissioning and quality assurance tests. The results of standard quality assurance (QA) machine tests and commissioning tests for volume modulated arc therapy (VMAT) using electronic portal image device (EPID) and 'EPIQA' software are presented. (authors)

  2. Good manufacturing practice - quality assurance programs

    International Nuclear Information System (INIS)

    Masefield, John; Thompson, Steven

    1986-01-01

    The concept of good manufacturing practice (GMP) in the medical device industry requires the use of controlled methods and equipment in performing each step in the device manufacturing process. Quality assurance programs are used to maintain compliance with GMP requirements by prescribing the operating and control procedures to be used. The specific elements of a quality assurance program for the radiation sterilization of medical devices are described. (author)

  3. Quality assurance and organizational effectiveness in hospitals.

    OpenAIRE

    Hetherington, R W

    1982-01-01

    The purpose of this paper is to explore some aspects of a general theoretical model within which research on the organizational impacts of quality assurance programs in hospitals may be examined. Quality assurance is conceptualized as an organizational control mechanism, operating primarily through increased formalization of structures and specification of procedures. Organizational effectiveness is discussed from the perspective of the problem-solving theory of organizations, wherein effecti...

  4. Quality assurance program for isotopic power systems

    Energy Technology Data Exchange (ETDEWEB)

    Hannigan, R.L.; Harnar, R.R.

    1982-12-01

    This report summarizes the Sandia National Laboratories Quality Assurance Program that applies to non-weapon (reimbursable) Radioisotopic Thermoelectric Generators. The program has been implemented over the past 16 years on power supplies used in various space and terrestrial systems. The quality assurance (QA) activity of the program is in support of the Department of Energy, Office of Space Nuclear Projects. Basic elements of the program are described in the report and examples of program decumentation are presented.

  5. Quality assurance program for isotopic power systems

    International Nuclear Information System (INIS)

    Hannigan, R.L.; Harnar, R.R.

    1982-12-01

    This report summarizes the Sandia National Laboratories Quality Assurance Program that applies to non-weapon (reimbursable) Radioisotopic Thermoelectric Generators. The program has been implemented over the past 16 years on power supplies used in various space and terrestrial systems. The quality assurance (QA) activity of the program is in support of the Department of Energy, Office of Space Nuclear Projects. Basic elements of the program are described in the report and examples of program decumentation are presented

  6. Westinghouse Water Reactor Divisions quality assurance plan

    International Nuclear Information System (INIS)

    1977-09-01

    The Quality Assurance Program used by Westinghouse Water Reactor Divisions is described. The purpose of the program is to assure that the design, materials, and workmanship on Nuclear Steam Supply System (NSSS) equipment meet applicable safety requirements, fulfill the requirements of the contracts with the applicants, and satisfy the applicable codes, standards, and regulatory requirements. This program satisfies the NRC Quality Assurance Criteria, 10CFR50 Appendix B, to the extent that these criteria apply to safety related NSSS equipment. Also, it follows the regulatory position provided in NRC regulatory guides and the requirements of ANSI Standard N45.2.12 as identified in this Topical Report

  7. Quality Assurance for Operation of Nuclear Facilities

    International Nuclear Information System (INIS)

    Park, C. G.; Kwon, H. I.; Kim, K. H.; Oh, Y. W.; Lee, Y. G.; Ha, J. H.; Lim, N. J.

    2008-12-01

    This report describes QA activities performed within 'Quality Assurance for Nuclear facility project' and results thereof. Efforts were made to maintain and improve quality system of nuclear facilities. Varification activities whether quality system was implemented in compliance with requirements. QA department assisted KOLAS accredited testing and calibration laboratories, ISO 9001 quality system, establishment of QA programs for R and D, and carried out reviews and surveys for development of quality assurance technologies. Major items of this report are as follows : - Development and Improvement of QA Programs - QA Activities - Assessment of Effectiveness and Adequacy for QA Programs

  8. [Quality assurance and quality improvement. Personal experiences and intentions].

    Science.gov (United States)

    Roche, B G; Sommer, C

    1995-01-01

    In may 1994 we were selected by the surgical Swiss association to make a study about quality in USA. During our travel we visited 3 types of institutions: Hospitals, National Institute of standard and Technology, Industry, Johnson & Johnson. We appreciate to compare 2 types of quality programs: Quality Assurance (QA) and Continuous Quality Improvement (CQI). In traditional healthcare circles, QA is the process established to meet external regulatory requirements and to assure that patient care is consistent with established standards. In a modern quality terms, QA outside of healthcare means designing a product or service, as well as controlling its production, so well that quality is inevitable. The ideas of W. Edward Deming is that there is never improvement just by inspection. He developed a theory based on 14 principles. A productive work is accomplished through processes. Understanding the variability of processes is a key to improve quality. Quality management sees each person in an organisation as part of one or more processes. The job of every worker is to receive the work of others, add value to that work, and supply it to the next person in the process. This is called the triple role the workers as customer, processor, and supplier. The main source of quality defects is problems in the process. The old assumption is that quality fails when people do the right thing wrong; the new assumption is that, more often, quality failures arise when people do the wrong think right. Exhortation, incentives and discipline of workers are unlikely to improve quality. If quality is failing when people do their jobs as designed, then exhorting them to do better is managerial nonsense. Modern quality theory is customer focused. Customers are identified internally and externally. The modern approach to quality is thoroughly grounded in scientific and statistical thinking. Like in medicine, the symptom is a defect in quality. The therapist of process must perform diagnostic

  9. Current conceptions of industrial quality assurance

    International Nuclear Information System (INIS)

    Zeller, H.

    1978-01-01

    In the electrical engineering industry quality assurance is mainly oriented in accordance with the customers', users', and consumers' requirements concerning the quality of products (including reliability). These requirements are as manifold as the range of products itself. They do not only comprise functional criteria, but also safety against malfunctions, bodily injury or property damage. Quality assurance is embedded in the overall activities of a company; the peripheral conditions, such as organization, profitability, qualification, and responsibility of staff have to be considered. Thus, quality assurance in the electrical engineering industry proceeds in efficient systems which are adapted to the individual forms of production. These systems may include planning, testing, feedback of quality data, statistical procedures, costs and profitability. Their obvious interaction is based on the system of coordinates of integrated quality control. The paper will illustrate the basic features of this interaction by reference to various examples. (orig.) [de

  10. Quality assurance in ionizing radiation application

    International Nuclear Information System (INIS)

    Rastkhah; Nasser.

    1995-01-01

    Quality assurance is a mean for controlling all the activities within an organization which affect the quality of the product or service. A series of international standards have been prepared which incorporate the accumulated knowledge and provide guidance on what activities within an organization should be controlled. A proposal on a quality assurance system to be implemented in ionizing radiation application centers is the primary concern of Atomic Energy Organization of Iran is represented. The Objectives were identification of quality related problems ;Comply with national and international requirements ;Controlling all activities within an organization which affects the quality and assurance of maintaining the quality within organization. In performing protection measures, risk, cost, benefit consideration, cause of problems and the classic solution are summarized in four chapters

  11. APPROACH TO QUALITY ASSURANCE IN HIGHER EDUCATION

    Directory of Open Access Journals (Sweden)

    Zora Arsovski

    2007-03-01

    Full Text Available Quality assurance in higher education is streamed in two interconnected concepts: (1 quality management according to ISO 9000 and (2 Bologna process. In this paper both concepts are presented, with point on internal state and term plan activities for quality improvement in higher education in Serbia.

  12. Transuranic Waste Characterization Quality Assurance Program Plan

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1995-04-30

    This quality assurance plan identifies the data necessary, and techniques designed to attain the required quality, to meet the specific data quality objectives associated with the DOE Waste Isolation Pilot Plant (WIPP). This report specifies sampling, waste testing, and analytical methods for transuranic wastes.

  13. Transuranic Waste Characterization Quality Assurance Program Plan

    International Nuclear Information System (INIS)

    1995-01-01

    This quality assurance plan identifies the data necessary, and techniques designed to attain the required quality, to meet the specific data quality objectives associated with the DOE Waste Isolation Pilot Plant (WIPP). This report specifies sampling, waste testing, and analytical methods for transuranic wastes

  14. Quality assurance, quality control and quality audit in diagnostic radiology

    International Nuclear Information System (INIS)

    Vassileva, J.

    2009-01-01

    Full text:The lecture aims to present contemporary view of quality assurance in X-Ray diagnosis and its practical realization in Bulgaria. In the lecture the concepts of quality assurance, quality control and clinical audit will be defined and their scope will be considered. An answer of the following questions will be given: why is it necessary to determine the dose of patient in X-ray studies, what is the reference dose level and how it is used for dosimetric quantity which characterized the patient's exposure in X-ray, mammography and CT scans and how they are measured, who conducted the measurement and how to keep the records, what are the variations of doses in identical tests and what defines them? The findings from a national survey of doses in diagnostic radiology, conducted in 2008-2009 and the developed new national reference levels will be presented. The main findings of the first tests of radiological equipment and the future role of quality control as well as the concept of conducting clinical audit and its role in quality assurance are also presented. Quality assurance of the diagnostic process with minimal exposure of patients is a strategic goal whose realization requires understanding, organization and practical action, both nationally and in every hospital. To achieve this the important role of education and training of physicians, radiological technicians and medical physicists is enhanced

  15. Quality Assurance in Higher Education

    OpenAIRE

    Nurdin, Nurdin

    2009-01-01

    Kualitas telah menjadi isu kritis dalam persaingan modern dewasa ini, dan hal itu telah menjadi beban tugas bagi para manager menengah. Dalam tataran abstrak kualitas telah didefinisikan oleh dua pakar penting bidang kualitas yaitu Joseph Juran dan Edward Deming. Mereka berdua telah berhasil menjadikan kualitas sebagai mindset yang berkembang terus dalam kajian managemen, khususnya managemen kualitas. Ouality assurance dalam dunia pendidikan adalah suatu keniscayaan seiring dengan terjadinya ...

  16. Automating linear accelerator quality assurance

    International Nuclear Information System (INIS)

    Eckhause, Tobias; Thorwarth, Ryan; Moran, Jean M.; Al-Hallaq, Hania; Farrey, Karl; Ritter, Timothy; DeMarco, John; Pawlicki, Todd; Kim, Gwe-Ya; Popple, Richard; Sharma, Vijeshwar; Park, SungYong; Perez, Mario; Booth, Jeremy T.

    2015-01-01

    Purpose: The purpose of this study was 2-fold. One purpose was to develop an automated, streamlined quality assurance (QA) program for use by multiple centers. The second purpose was to evaluate machine performance over time for multiple centers using linear accelerator (Linac) log files and electronic portal images. The authors sought to evaluate variations in Linac performance to establish as a reference for other centers. Methods: The authors developed analytical software tools for a QA program using both log files and electronic portal imaging device (EPID) measurements. The first tool is a general analysis tool which can read and visually represent data in the log file. This tool, which can be used to automatically analyze patient treatment or QA log files, examines the files for Linac deviations which exceed thresholds. The second set of tools consists of a test suite of QA fields, a standard phantom, and software to collect information from the log files on deviations from the expected values. The test suite was designed to focus on the mechanical tests of the Linac to include jaw, MLC, and collimator positions during static, IMRT, and volumetric modulated arc therapy delivery. A consortium of eight institutions delivered the test suite at monthly or weekly intervals on each Linac using a standard phantom. The behavior of various components was analyzed for eight TrueBeam Linacs. Results: For the EPID and trajectory log file analysis, all observed deviations which exceeded established thresholds for Linac behavior resulted in a beam hold off. In the absence of an interlock-triggering event, the maximum observed log file deviations between the expected and actual component positions (such as MLC leaves) varied from less than 1% to 26% of published tolerance thresholds. The maximum and standard deviations of the variations due to gantry sag, collimator angle, jaw position, and MLC positions are presented. Gantry sag among Linacs was 0.336 ± 0.072 mm. The

  17. Automating linear accelerator quality assurance

    Energy Technology Data Exchange (ETDEWEB)

    Eckhause, Tobias; Thorwarth, Ryan; Moran, Jean M., E-mail: jmmoran@med.umich.edu [Department of Radiation Oncology, University of Michigan, Ann Arbor, Michigan 48109-5010 (United States); Al-Hallaq, Hania; Farrey, Karl [Department of Radiation Oncology and Cellular Oncology, The University of Chicago, Chicago, Illinois 60637 (United States); Ritter, Timothy [Ann Arbor VA Medical Center, Ann Arbor, Michigan 48109 (United States); DeMarco, John [Department of Radiation Oncology, Cedars-Sinai Medical Center, Los Angeles, California, 90048 (United States); Pawlicki, Todd; Kim, Gwe-Ya [UCSD Medical Center, La Jolla, California 92093 (United States); Popple, Richard [Department of Radiation Oncology, University of Alabama Birmingham, Birmingham, Alabama 35249 (United States); Sharma, Vijeshwar; Park, SungYong [Karmanos Cancer Institute, McLaren-Flint, Flint, Michigan 48532 (United States); Perez, Mario; Booth, Jeremy T. [Royal North Shore Hospital, Sydney, NSW 2065 (Australia)

    2015-10-15

    Purpose: The purpose of this study was 2-fold. One purpose was to develop an automated, streamlined quality assurance (QA) program for use by multiple centers. The second purpose was to evaluate machine performance over time for multiple centers using linear accelerator (Linac) log files and electronic portal images. The authors sought to evaluate variations in Linac performance to establish as a reference for other centers. Methods: The authors developed analytical software tools for a QA program using both log files and electronic portal imaging device (EPID) measurements. The first tool is a general analysis tool which can read and visually represent data in the log file. This tool, which can be used to automatically analyze patient treatment or QA log files, examines the files for Linac deviations which exceed thresholds. The second set of tools consists of a test suite of QA fields, a standard phantom, and software to collect information from the log files on deviations from the expected values. The test suite was designed to focus on the mechanical tests of the Linac to include jaw, MLC, and collimator positions during static, IMRT, and volumetric modulated arc therapy delivery. A consortium of eight institutions delivered the test suite at monthly or weekly intervals on each Linac using a standard phantom. The behavior of various components was analyzed for eight TrueBeam Linacs. Results: For the EPID and trajectory log file analysis, all observed deviations which exceeded established thresholds for Linac behavior resulted in a beam hold off. In the absence of an interlock-triggering event, the maximum observed log file deviations between the expected and actual component positions (such as MLC leaves) varied from less than 1% to 26% of published tolerance thresholds. The maximum and standard deviations of the variations due to gantry sag, collimator angle, jaw position, and MLC positions are presented. Gantry sag among Linacs was 0.336 ± 0.072 mm. The

  18. Quality assurance in dental radiology

    International Nuclear Information System (INIS)

    Lorber, C.G.

    1992-01-01

    The quality criteria that have determined and the quality optimization measures defined have to regularly checked in order to guarantee the quality standards. The quality control programme is laid down in the publiction of the WHO (ISO 3534-1977), referring to the quality control of equipment, film processing techniques, and to the qualification of the medical and technical personnel. (DG) [de

  19. Quality assurance in the fuel fabrication

    International Nuclear Information System (INIS)

    Darmayan, P.

    1995-01-01

    The paper concentrates on the evolutions that FBFC Franco Belge de Fabrication de Combustible has initiated in order to make a further step in improving quality: 1. Improving each personnel's involment and responsability towards quality. 2. Incorporating quality assurance in a total quality management policy, involving both the fabrication teams of FBFC and the design teams of Framatome in order to improve quality. (orig./HP)

  20. Nuclear quality assurance operating philosophy: A quality-oriented approach

    International Nuclear Information System (INIS)

    Corcoran, W.R.; Geiger, J.E.; Heibel, R.E.; Cotton, J.B.; Sabol, A.R.

    1992-01-01

    Quality assurance programs have been part of the nuclear utility management process since the publication of the draft of 10CFR50 Appendix B in the late 1960s. The unwritten operational philosophy of nuclear quality assurance organizations focused on compliance with federal regulations. Adverse experiences, including operational events and extended shutdowns, prompted the gradual adoption of isolated practices extending beyond compliance orientation. These practices have an orientation that accommodates a definition of quality, a perspective of the role of nuclear quality assurance organizations in the overall concept of defense-in-depth, a definition of the segments of the nuclear quality assurance mission, and recent advances in the understanding of self-assessment. Observation of these practices at various nuclear utilities resulted in a syntheses of practices and approaches into a coherent quality-oriented nuclear quality assurance operating philosophy that is not totally adopted at any one utility

  1. [Quality assurance concepts in intensive care medicine].

    Science.gov (United States)

    Brinkmann, A; Braun, J P; Riessen, R; Dubb, R; Kaltwasser, A; Bingold, T M

    2015-11-01

    Intensive care medicine (ICM) is characterized by a high degree of complexity and requires intense communication and collaboration on interdisciplinary and multiprofessional levels. In order to achieve good quality of care in this environment and to prevent errors, a proactive quality and error management as well as a structured quality assurance system are essential. Since the early 1990s, German intensive care societies have developed concepts for quality management and assurance in ICM. In 2006, intensive care networks were founded in different states to support the implementation of evidence-based knowledge into clinical routine and to improve medical outcome, efficacy, and efficiency in ICM. Current instruments and concepts of quality assurance in German ICM include core intensive care data from the data registry DIVI REVERSI, quality indicators, peer review in intensive care, IQM peer review, and various certification processes. The first version of German ICM quality indicators was published in 2010 by an interdisciplinary and interprofessional expert commission. Key figures, indicators, and national benchmarks are intended to describe the quality of structures, processes, and outcomes in intensive care. Many of the quality assurance tools have proved to be useful in clinical practice, but nationwide implementation still can be improved.

  2. 10 CFR 63.142 - Quality assurance criteria.

    Science.gov (United States)

    2010-01-01

    ... planned and periodic audits to verify compliance with all aspects of the quality assurance program and to... 10 Energy 2 2010-01-01 2010-01-01 false Quality assurance criteria. 63.142 Section 63.142 Energy... REPOSITORY AT YUCCA MOUNTAIN, NEVADA Quality Assurance § 63.142 Quality assurance criteria. (a) Introduction...

  3. Quality assurance system in nuclear engineering

    International Nuclear Information System (INIS)

    Adams, H.W.; Hoensch, V.

    1985-01-01

    Due to the close connection between the German Atomic Energy Law and the nuclear control regulations, quality systems in nuclear engineering have taken on a special form. Quality assurance systems as a stipulated organisation of structure and procedure to assure quality have implications for the organisation of the electric supply company at the planning, erection and commissioning stage and for the organisation of the nuclear power station facility. To supervise the application and effectiveness of the stipulated organisation of structure and procedure internally and externally among contractors, special organisation units have been set up at the plant suppliers, manufactures, electric supply companies and nuclear power station facilities, which in the electric supply field go by the name of Quality Assurance Supervision. (orig.) [de

  4. Hanford Tanks Initiative quality assurance implementation plan

    International Nuclear Information System (INIS)

    Huston, J.J.

    1998-01-01

    Hanford Tanks Initiative (HTI) Quality Assurance Implementation Plan for Nuclear Facilities defines the controls for the products and activities developed by HTI. Project Hanford Management Contract (PHMC) Quality Assurance Program Description (QAPD)(HNF-PRO599) is the document that defines the quality requirements for Nuclear Facilities. The QAPD provides direction for compliance to 10 CFR 830.120 Nuclear Safety Management, Quality Assurance Requirements. Hanford Tanks Initiative (HTI) is a five-year activity resulting from the technical and financial partnership of the US Department of Energy's Office of Waste Management (EM-30), and Office of Science and Technology Development (EM-50). HTI will develop and demonstrate technologies and processes for characterization and retrieval of single shell tank waste. Activities and products associated with HTI consist of engineering, construction, procurement, closure, retrieval, characterization, and safety and licensing

  5. Repository construction management and quality assurance

    International Nuclear Information System (INIS)

    Hood, F.C.

    1984-01-01

    An emphasis on preventive rather than reactive management is key to an efficient construction management operation. Development of contingency plans to deal with unexpected adverse conditions, e.g., brine pockets during mining operations, are an integral part of the management program to ensure project safety, quality, cost, schedule and environmental objectives are met. A viable quality assurance program with active management support will optimize management effectiveness in reaching project goals. With adequate planning and perceptive application of the proper management controls, Quality Assurance becomes an essential ingredient for efficiently managing a job because it has been built into the management system rather than being an uninvolved peripheral entity. 6 references, 3 figures

  6. Nuclear powerplant functions: quality assurance, construction

    International Nuclear Information System (INIS)

    Karpa, P.

    1984-01-01

    The author proposes that multilayer Quality Control is burdensome and ineffective. He proposes that the earlier approaches of having responsible field engineers back on the job site instead of at a home office be reinitiated to speed up necessary design changes and hold down costs. It is then the job of the quality control personnel to assure that the field engineer is doing his job. The idea of using the reactor start-up process as part of the quality assurance program is also proposed. Also discussed is the idea of Operating License Contracts or One Step Licensing Approach

  7. Quality assurance programme for screen film mammography

    International Nuclear Information System (INIS)

    2009-01-01

    The application of radiation in human health, for both the diagnosis and treatment of disease, is an important component of the work of the IAEA. In the area of diagnostic radiology, this work is focused on quality assurance methods to both the promotion of the effective use of radiation for diagnostic outcome, through achieving and maintaining appropriate image quality, and also on dose determination to allow the monitoring and reduction of dose to the patient. In response to heightened awareness of the importance of patient dose contributed by radiology procedures, the IAEA published Dosimetry in Diagnostic Radiology: An International Code of Practice (Technical Reports Series No. 457) in 2007, to form a basis for patient dose determination for the Member States. Further to this, it is recognized that for complex diagnostic procedures, such as mammography, a detailed guidance document is required to give the professionals in the clinical centre the knowledge necessary to assess the patient dose, as well as to ensure that the procedure gives the maximal patient benefit possible. It is well documented that without the implementation of a quality culture and a systematic quality assurance programme with appropriate education, the detection of breast cancer cannot be made at an early enough stage to allow effective curative treatment to be undertaken. Currently there are a number of established quality assurance protocols in mammography from national and regional institutions, however, many of these protocols are distinctive and so a harmonized approach is required. This will allow the Member States to facilitate quality assurance in mammography in a standardized way which will also facilitate the introduction of national quality assurance programmes that are needed to underpin effective population screening programmes for breast cancer. Development of a quality assurance document for screen film mammography was started in 2005 with the appointment of a drafting

  8. Quality Assurance in University Guidance Services

    Science.gov (United States)

    Simon, Alexandra

    2014-01-01

    In Europe there is no common quality assurance framework for the delivery of guidance in higher education. Using a case study approach in four university career guidance services in England, France and Spain, this article aims to study how quality is implemented in university career guidance services in terms of strategy, standards and models,…

  9. Quality assurance of nuclear medicine instruments

    International Nuclear Information System (INIS)

    Soni, P.S.

    1998-01-01

    Quality assurance in nuclear medicine refers collectively to all aspects of a nuclear medicine programme that may contribute directly or indirectly to the quality of the results obtained. For examples, patients scheduling; preparation and dispensing of radiopharmaceutical; the protection of patients, staff and the general public against radiation hazards and accidents caused by faulty instruments; methodology, data interpretation and record keeping

  10. Ensuring Quality Assurance in Vocational Education

    Science.gov (United States)

    Idialu, Ethel E.

    2013-01-01

    Vocational education emphasises skill acquisition. Quality assurance in vocational education is a concept that is concerned with high performance involving activities with vocational education such as teaching, learning, infrastructures, students' behaviour and the entire academic process. Quality vocational education refers to input and output of…

  11. Supervision and Quality Assurance Strategies in Education ...

    African Journals Online (AJOL)

    This paper examines the need for quality assurance and quality control strategies in improving the effectiveness of educational provision and teacher performance in schools. Governments all over the word in an attempt to educate and develop their citizens spend huge amount of money on teachers and schools but in most ...

  12. Quality assurance for diabetic retinopathy telescreening.

    Science.gov (United States)

    Schneider, S; Aldington, S J; Kohner, E M; Luzio, S; Owens, D R; Schmidt, V; Schuell, H; Zahlmann, G

    2005-06-01

    TOSCA was an EU-Commission supported international research project designed to develop telescreening services in diabetic retinopathy and glaucoma. This paper describes the quality assurance methods developed for the diabetic retinopathy telescreening service within the TOSCA project. The study was performed in 1895 patients with diabetes between 2000 and 2002 at diabetic retinopathy screening sites in five European countries. Data were analysed centrally. Patients attending each clinic's diabetic retinopathy screening service received standardized retinal photography. The images and associated data were transferred electronically to a remote location for grading. Each photographer uploading images and each grader downloading images for assessment was controlled by a systematic quality management approach. The quality assurance measures defined were image quality, intragrader reliability. A cockpit chart was developed for the management and presentation of relevant results and quality measures. For the intragrader reliability tests, 10% of the images were processed for a second grading. An algorithm for calculating differences between repeated gradings was developed. The assessment of image quality for the different sites showed that only 0-0.7% were unassessable. One hundred per cent agreement for both gradings was achieved in 50-85% of graded cases, depending on site and grader, and an agreement better than 95% in 71-100% of cases. A telemedicine-supported quality assurance process is practical and advantageous. The cockpit charts have proven to be useful tools when monitoring the performance of a telescreening service. Grader feedback showed high satisfaction with the quality assurance process.

  13. Quality assurance when refitting - SUSAN example

    International Nuclear Information System (INIS)

    Gautier, R.

    1992-01-01

    The most important points of quality assurance for the realisation of the SUSAN project (special independent system for the dissipation of post-decay heat) at the Muehleberg nuclear power station are discussed in this article. The periodic controls and function tests which have been performed since August 1989, confirm the quality of the products used

  14. Terms and definitions of quality assurance/quality control

    International Nuclear Information System (INIS)

    Kaden, W.

    1980-01-01

    Terms of quality assurance are defined and interpreted. Reference is made to the IAEA Code of Practice and to other important Codes and Standards like ANSI, ASME and KTA. The relevance of these terms to everyday's work and problems of a quality assurance engineer is explained. (orig.)

  15. Statistical methods in quality assurance

    International Nuclear Information System (INIS)

    Eckhard, W.

    1980-01-01

    During the different phases of a production process - planning, development and design, manufacturing, assembling, etc. - most of the decision rests on a base of statistics, the collection, analysis and interpretation of data. Statistical methods can be thought of as a kit of tools to help to solve problems in the quality functions of the quality loop with respect to produce quality products and to reduce quality costs. Various statistical methods are represented, typical examples for their practical application are demonstrated. (RW)

  16. Quality Assurance of Chemical Measurements.

    Science.gov (United States)

    Taylor, John K.

    1981-01-01

    Reviews aspects of quality control (methods to control errors) and quality assessment (verification that systems are operating within acceptable limits) including an analytical measurement system, quality control by inspection, control charts, systematic errors, and use of SRMs, materials for which properties are certified by the National Bureau…

  17. 12: Assuring the quality of critical software

    International Nuclear Information System (INIS)

    Jacky, J.; Kalet, I.

    1987-01-01

    The authors recommend quality assurance procedures for radiation therapy software. Software quality assurance deals with preventing, detecting and repairing programming errors. Error detection difficulties are most severe in computer-based control systems, for example therapy machine control systems, because it may be impossible for users to confirm correct operation while treatments are in progress, or to intervene if things go wrong. Software quality assurance techniques observed in other industries in which public safety is at risk are reviewed. In some of these industries software must be approved or certified before it can be used. Approval is subject to technical reviews and audits by experts other than the program authors. The main obstacles to adoption of these techniques in the radiation therapy field are costs, lack of familiarity and doubts regarding efficacy. 18 refs

  18. Quality assurance during site construction. Pt. 1

    International Nuclear Information System (INIS)

    Mueller, J.

    1980-01-01

    The first part of the lecture deals with the Quality Assurance system on the construction site in general. Basic site-related problems during contract implementation and the QA system requirements resulting from them are presented. The compilation of these requirements in a QA program and its inclusion in the site manual in written form are explained. Site organization, personnel qualification and procedures are referred to. Whereas the first part shows what is to be done, the second part shows how it can be put into practice on the site. All the essential points for the assurance of quality are addressed. They include, e.g., review of documents, incoming goods control, in-process surveillance, store controls, identification of components and systems, dealing with changes and deviations, documentation control and audits. By means of examples taken form practice the necessity of a well-functioning QA system, and the importance of quality-assuring measures on the site are pointed out. (orig.)

  19. Assuring quality in high-consequence engineering

    Energy Technology Data Exchange (ETDEWEB)

    Hoover, Marcey L.; Kolb, Rachel R.

    2014-03-01

    In high-consequence engineering organizations, such as Sandia, quality assurance may be heavily dependent on staff competency. Competency-dependent quality assurance models are at risk when the environment changes, as it has with increasing attrition rates, budget and schedule cuts, and competing program priorities. Risks in Sandia's competency-dependent culture can be mitigated through changes to hiring, training, and customer engagement approaches to manage people, partners, and products. Sandia's technical quality engineering organization has been able to mitigate corporate-level risks by driving changes that benefit all departments, and in doing so has assured Sandia's commitment to excellence in high-consequence engineering and national service.

  20. Quality assurance and applied statistics. Method 3

    International Nuclear Information System (INIS)

    1992-01-01

    This German-Industry-Standards-paperback contains the International Standards from the Series ISO 9000 (or, as the case may be, the European Standards from the Series EN 29000) concerning quality assurance and including the already completed supplementary guidelines with ISO 9000- and ISO 9004-section numbers, which have been adopted as German Industry Standards and which are observed and applied world-wide to a great extent. It also includes the German-Industry-Standards ISO 10011 parts 1, 2 and 3 concerning the auditing of quality-assurance systems and the German-Industry-Standard ISO 10012 part 1 concerning quality-assurance demands (confirmation system) for measuring devices. The standards also include English and French versions. They are applicable independent of the user's line of industry and thus constitute basic standards. (orig.) [de

  1. Quality assurance in nuclear installations

    International Nuclear Information System (INIS)

    Torres M, Nelson.

    1985-08-01

    It has been proven that the bad quality of products, equipment, installations, and services is not due to the lack of tests, experiments and verifications. The main causes are associated with insufficient organization of the activities that have influence on the quality. The garantee of quality is conceptualized as an appropriate instrument composed of normalized criteria initially in advanced technologies. Such as nuclear science and aerospace technology. However, with the appropriate modifications it can be applied to conventional technologies

  2. Statistical process control for radiotherapy quality assurance

    International Nuclear Information System (INIS)

    Pawlicki, Todd; Whitaker, Matthew; Boyer, Arthur L.

    2005-01-01

    Every quality assurance process uncovers random and systematic errors. These errors typically consist of many small random errors and a very few number of large errors that dominate the result. Quality assurance practices in radiotherapy do not adequately differentiate between these two sources of error. The ability to separate these types of errors would allow the dominant source(s) of error to be efficiently detected and addressed. In this work, statistical process control is applied to quality assurance in radiotherapy for the purpose of setting action thresholds that differentiate between random and systematic errors. The theoretical development and implementation of process behavior charts are described. We report on a pilot project is which these techniques are applied to daily output and flatness/symmetry quality assurance for a 10 MV photon beam in our department. This clinical case was followed over 52 days. As part of our investigation, we found that action thresholds set using process behavior charts were able to identify systematic changes in our daily quality assurance process. This is in contrast to action thresholds set using the standard deviation, which did not identify the same systematic changes in the process. The process behavior thresholds calculated from a subset of the data detected a 2% change in the process whereas with a standard deviation calculation, no change was detected. Medical physicists must make decisions on quality assurance data as it is acquired. Process behavior charts help decide when to take action and when to acquire more data before making a change in the process

  3. Quality assurance program. Topical report, GIBSAR-7

    International Nuclear Information System (INIS)

    1975-09-01

    The quality assurance program developed by Gibbs and Hill to satisfy the requirement that design, engineering, procurement, fabrication, and construction activities for nuclear power plants are performed in accordance with applicable codes, standards, and regulatory criteria is outlined. The program was developed to conform to the criteria of Appendix B to 10 CFR Part 50 and is presented in such a manner that each of the 18 criteria are individually set forth. The Gibbs and Hill program, implemented by the procedures of the corporate Quality Assurance Manual also follows the guidelines of the NRC Gray Book, WASH 1283, Rev. 1, May 24, 1974, and Green Book, WASH 1309, May 10, 1974. (auth)

  4. The quality assurance practice in Spain

    International Nuclear Information System (INIS)

    Mugica, A.P.

    1980-01-01

    Even when the basic requirements for a Quality Assurance Program are delineated in documents such as the Code of Federal Regulations or Standards like ANSI N 45. 2, the way in which these requirements are put into practice is very dependent on the organization to which they are applied. So, in order to approach accurately the Quality Assurance practice and experience in Spain, the legal and industrial scenario must be considered. We are trying to present an outlook of the Spanish Energy Plan, Regulations and Nuclear Industry. (orig.)

  5. Quality Assurance Source Requirements Traceability Database

    International Nuclear Information System (INIS)

    MURTHY, R.; NAYDENOVA, A.; DEKLEVER, R.; BOONE, A.

    2006-01-01

    At the Yucca Mountain Project the Project Requirements Processing System assists in the management of relationships between regulatory and national/industry standards source criteria, and Quality Assurance Requirements and Description document (DOE/R W-0333P) requirements to create compliance matrices representing respective relationships. The matrices are submitted to the U.S. Nuclear Regulatory Commission to assist in the commission's review, interpretation, and concurrence with the Yucca Mountain Project QA program document. The tool is highly customized to meet the needs of the Office of Civilian Radioactive Waste Management Office of Quality Assurance

  6. Quality assurance technical cooperation and training

    International Nuclear Information System (INIS)

    Chen, C.K.

    1993-01-01

    An IAEA Manual (TRS 340) which provides guidance for establishing training programme covering Quality Assurance principles and practices was published in 1992. The document is mainly based on the experience and material collected through the performance of some 50 interregional, regional and national training courses, seminars and workshops on Quality Assurance organized by the IAEA in about 20 countries. The purpose of this document is to provide a systematic approach for use by the responsible management in developing an overall QA training programme and lecture material for all personnel of a nuclear power plant. The document can be suitably adjusted for various management levels and adapted to the national variables and needs

  7. Nuclear quality assurance: indoctrination and training

    International Nuclear Information System (INIS)

    Sternberg, A.

    1977-01-01

    Quality Assurance is defined as ''all the planned and systematic actions necessary to provide adequate confidence that a structure, system or component will perform satisfactorily in service''. Within Public Service Electric and Gas Company (PSEandG) Quality Assurance, a discipline which involves everyone within the company, is considered. In order to economically and effectively communicate this discipline throughout the concerned areas of the Company so that involved personnel are made fully aware of the complete scope of their tasks, a detailed comprehensive indoctrination and training program has been developed and implemented. 3 refs

  8. 40 CFR 160.35 - Quality assurance unit.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 23 2010-07-01 2010-07-01 false Quality assurance unit. 160.35 Section... LABORATORY PRACTICE STANDARDS Organization and Personnel § 160.35 Quality assurance unit. (a) A testing facility shall have a quality assurance unit which shall be responsible for monitoring each study to assure...

  9. The successful Chief Executive Officer understands quality assurance

    International Nuclear Information System (INIS)

    Hedges, D.

    1984-01-01

    The successful Chief Executive Officer (CEO) will have recognized the benefits of, and have implemented, a total quality assurance program. The quality assurance program will be adequately defined in policies and procedures such that managers and supervisors of each organizational element understand their primary and supporting roles in carrying out an effective quality assurance program. The traditional practice of having all quality assurance activities reside in a quality assurance organization will have been cast aside. Instead, the quality assurance activities necessary to achieve and assure the quality of the desired end product will have been defined and assigned to responsible organization elements. The quality assurance organization's primary role will be to define the total quality assurance program, insure that the achieving and assuring functions are assigned in policies and procedures, conduct training necessary to have management and supervisors understand the total quality assurance program, measure the effectiveness of the program and feedback measurement data for improvements in the program. The successful CEO will have implemented a quality assurance program that provides for a graded approach for application of the program based upon the importance of the intended use of the product or service. The successful CEO will rely heavily on the scheduled progress reports and assessments to measure the pulse of his organization's successes and improvement needs. This paper will describe suggested approaches for the Quality Assurance Manager to implement a quality assurance program which results in his corporation's CEO being a supporter of and a driving force in the implementation of the quality assurance program

  10. Quality assurance programme and responsibility

    International Nuclear Information System (INIS)

    Lee Peter

    2004-01-01

    The contents of this chapter are follows - Quality Control of Equipment and Facilities, Monitoring and Analysis of Film Reject Rate, Continuous Medical Education (CME), Audit of X-Ray Radiographs, General Principles, Good Image Criteria

  11. Quality Assurance of Ultrasonic Diagnosis in Breast

    Energy Technology Data Exchange (ETDEWEB)

    Chung, Soo Young; Kim, Hong Dae [Hallym University, Kangnam Sacred Heart Hospital, Seoul (Korea, Republic of)

    2006-06-15

    Sonography is a subjective diagnostic method which is highly dependent on the experience of the operator and the equipment quality which requires real-time adjustments. Breast screening examination currently consists of clinical examination and mammography. Breast sonography, either supplementary to mammography or independently, is indicated for the dense breast, especially in younger women. Breast sonography is especially applicable for Korean women because of the denser breast parenchyma and the approximately 10-year younger incidence rate of breast cancer of Korean women compared to western women. To avoid unnecessary breast biopsy because of the high rate of false positive lesions in breast parenchyma, which is different from other body organs such as the liver or the kidney, a quality assurance program for breast sonography is essential. The quality assurance of breast ultrasound involves quality assurance of the equipment, imaging display and acquisition of clinical images, personnel qualifications and other aspects such as unification of lexicon, guideline of diagnostic examination and reporting system; US BI-RAD reporting system, assessment items and organization, education program, medical audit, certification issues, and medicolegal issues. A breast sonographic quality assurance system should be established before a scheme to initiate governmental medical insurance for breast sonography

  12. Quality Assurance of Ultrasonic Diagnosis in Breast

    International Nuclear Information System (INIS)

    Chung, Soo Young; Kim, Hong Dae

    2006-01-01

    Sonography is a subjective diagnostic method which is highly dependent on the experience of the operator and the equipment quality which requires real-time adjustments. Breast screening examination currently consists of clinical examination and mammography. Breast sonography, either supplementary to mammography or independently, is indicated for the dense breast, especially in younger women. Breast sonography is especially applicable for Korean women because of the denser breast parenchyma and the approximately 10-year younger incidence rate of breast cancer of Korean women compared to western women. To avoid unnecessary breast biopsy because of the high rate of false positive lesions in breast parenchyma, which is different from other body organs such as the liver or the kidney, a quality assurance program for breast sonography is essential. The quality assurance of breast ultrasound involves quality assurance of the equipment, imaging display and acquisition of clinical images, personnel qualifications and other aspects such as unification of lexicon, guideline of diagnostic examination and reporting system; US BI-RAD reporting system, assessment items and organization, education program, medical audit, certification issues, and medicolegal issues. A breast sonographic quality assurance system should be established before a scheme to initiate governmental medical insurance for breast sonography

  13. Quality Assurance in the Presence of Variability

    Science.gov (United States)

    Lauenroth, Kim; Metzger, Andreas; Pohl, Klaus

    Software Product Line Engineering (SPLE) is a reuse-driven development paradigm that has been applied successfully in information system engineering and other domains. Quality assurance of the reusable artifacts of the product line (e.g. requirements, design, and code artifacts) is essential for successful product line engineering. As those artifacts are reused in several products, a defect in a reusable artifact can affect several products of the product line. A central challenge for quality assurance in product line engineering is how to consider product line variability. Since the reusable artifacts contain variability, quality assurance techniques from single-system engineering cannot directly be applied to those artifacts. Therefore, different strategies and techniques have been developed for quality assurance in the presence of variability. In this chapter, we describe those strategies and discuss in more detail one of those strategies, the so called comprehensive strategy. The comprehensive strategy aims at checking the quality of all possible products of the product line and thus offers the highest benefits, since it is able to uncover defects in all possible products of the product line. However, the central challenge for applying the comprehensive strategy is the complexity that results from the product line variability and the large number of potential products of a product line. In this chapter, we present one concrete technique that we have developed to implement the comprehensive strategy that addresses this challenge. The technique is based on model checking technology and allows for a comprehensive verification of domain artifacts against temporal logic properties.

  14. An operational health physics quality assurance program

    International Nuclear Information System (INIS)

    Costigan, S.A.; McAtee, J.L. III; Somers, W.M.; Huchton, R.L.

    1996-01-01

    DOE Order 5700.6C, Quality Assurance, stipulates QA requirements for all DOE activities. This order is now codified as 10CFR830.120, Nuclear Safety Management, Quality Assurance Requirements, which is applicable to DOE nuclear facilities. A Quality Assurance Management Plan (QAMP) was developed by the Health Physics Operations Group (ESH-1) at Los Alamos National Laboratory (LANL). The goal of the ESH-1 QAMP is to ensure that operational radiation protection activities meet the criteria outlined in DOE Order 5700.6C, DOE-ER-STD-6001-92 and 10CFR830.120. The ten required elements are QA Program, Personal Training and Qualifications, Quality Improvement, Documents and Records, Work Processes, Design, Procurement, Inspection and Acceptance Testing, Management Assessment and Independent Assessment. The QAMP has been useful for the development of QAMPs at nuclear facilities and has helped ensure uniformity of institutional requirements where Health Physics services are deployed to facilities. To implement a subset of QAMP requirements, a Quality Assurance Self-Evaluation Program (QASE) was established. This program provides a novel self-audit mechanism for the formal identification and correction of non-conforming items related to Operational Health Physics. Additionally, the QASE is a useful management tool for Radiological Control Technician Supervisors and staff and provides a tracking mechanism for ongoing problem areas. Data have been Collected for two calendar years on a number of concerns that fall into four general categories: radiological posting and labeling, instrumentation, monitoring requirements, and radiological documents/records

  15. Quality assurance tracking and trending system (QATTS)

    International Nuclear Information System (INIS)

    Anderson, W.J.

    1987-01-01

    In 1984, The Philadelphia Electric Company (PECo) Quality Assurance (QA) Division recognized a need to modify the existing quality finding tracking program to generate a nuclear trending program that could detect trends of PECo-initiated findings that were not detectable to a day-to-day observer. Before 1984, each quality organization in PECo had a separate tracking system. An adequate quality trending program demanded that all findings be tracked in a common data base. The Quality Assurance Tracking and Trending System (QATTS) is divided into two parts, an on-line subsystem that provides access to QATTS data via corporate computer data screens and a reports and graphics subsystem that connects commercially available reports and graphic software computer packages to the QATTS data base. The QATTS can be accessed from any terminal connected to the main frame computer at PECo headquarters. The paper discusses the tracking system, report generation, responsible organization commitment tracking system (ROCT), and trending program

  16. Consumer demand and quality assurance

    DEFF Research Database (Denmark)

    Grunert, Klaus G; Wognum, Nel; Trienekens, Jacques

    2011-01-01

    Consumers differ in their demands, and this mau have implications for the type of supply chain governance that is most suitable for serving them. We present a segmentation of pork consumers in the EU based on their food-related lifestyles and demand for different pork products. We then present...... an inventory of pork chain governance and quality management systems, also resulting from a pan-European study, and attempt to match types of chains to consumer segments, arguing that the type of quality demanded by the consumers has implications especially for the quality management system governing the chain......, and that these implications are different for fresh meat and processed meat. The paper closes with a call for more collaboration between chain researchers and consumer researchers....

  17. Proactive quality assurance in environmental research

    International Nuclear Information System (INIS)

    Flanagan, J.B.; Kulkarni, S.V.; Wasson, S.J.; Ford, J.S.; Harmon, D.L.

    1991-01-01

    The Quality Assurance policy of the US Environmental Protection Agency (EPA) stipulates that every project involving environmentally related monitoring, measurements, and data collection activities must have a written and approved quality assurance project plan (QAPjP). A QAPjP is a written document which presents, in specific terms, the policies, organizations, objectives, functional activities, and the quality assurance/quality control activities designed to achieve the quality goals for data collection. In the research studies involving novel or non-routine measurements that use unvalidated methods, measurement quality goals are often difficult or impossible to specify at the beginning of the project for which a QAPjP must be written. Furthermore, it may not be possible for the QAPjP reviewers to evaluate the reasonableness of these goals without initial information about the system under study. For the project to evaluate chlorofluorocarbon for recycling from domestic refrigerators, the QAPjP incorporated standard analytical techniques used by industry. These techniques did not provide accuracy and precision or other validation information. For the initial version of the QAPjP, measurement quality goals were assigned based on limited experience. Quality assurance support was called upon to evaluate the performance of the measurement system for this project through a series of audits. The performance evaluation audits necessitated designing novel audit materials and sample delivery techniques. Continued interaction is necessary between the project and QA teams to permit evolution of reasonable data quality indicators for meaningful assessment of data quality. By treating the QAPjP as a living document that is updated and amended as more knowledge of a system is obtained, AQ becomes an integral part of the research program. This results in a greater understanding of the system under study

  18. Quality assurance for passive houses

    NARCIS (Netherlands)

    Visscher, H.J.; Mlecnik, E.

    2009-01-01

    For newly built houses national ambitions prescribe increasing levels of energy performances, even including achieving net zero energy or carbon neutral houses. This is in large contrast with the lack of quality in many building processes. The building regulations, processes and control will have to

  19. Quality assurance in biomedical neutron activation analysis

    International Nuclear Information System (INIS)

    1984-01-01

    The summary report represents an attempt to identify some of the possible sources of error in in vitro neutron activation analysis of trace elements applied to specimens of biomedical origin and to advise on practical means to avoid them. The report is intended as guidance for all involved in analysis, including sample collection and preparation for analysis. All these recommendations constitute part of quality assurance which is here taken to encompass the two concepts - quality control and quality assessment. Quality control is the mechanism established to control errors, while quality assessment is the mechanism used to verify that the analytical procedure is operating within acceptable limits

  20. Quality Assurance for Higher Education Franchising.

    Science.gov (United States)

    Yorke, Mantz

    1993-01-01

    The practice of "franchising" higher education programs, or provision of educational programs through vendors, is examined as it occurs in the United Kingdom as a result of recent educational policy changes. A set of principles for assuring the quality of such programs is proposed. (MSE)

  1. FURNAS activities in safety and quality assurance

    International Nuclear Information System (INIS)

    Dezordi, W.L.; Correa Filho, S.M.; Sacco, W.; Morais, L.H.G. de

    1980-01-01

    The aspects involved in the quality assurance performed by FURNAS for Nuclear Power Plant - Angra Unit I, are shown. Furnas' responsabilities in the licensing regarding reactor safety are also discussed. A summary of the computer codes used in the licensing process is given. (e.G.) [pt

  2. Nursing Quality Assurance: The Wisconsin System

    Science.gov (United States)

    Hover, Julie; Zimmer, Marie J.

    1978-01-01

    Evaluation model guidelines for hospital departments of nursing to use in their nursing quality assurance programs are presented as developed in Wisconsin. Four essential components of the Wisconsin outcome evaluation system are criteria, assessment, standards, and improvement of care. Sample tests and charts are included in the article. (MF)

  3. Quality Assurance of University Education: Whose Responsibility?

    Science.gov (United States)

    Ibijola, Elizabeth Yinka

    2015-01-01

    This study sought the opinion of stakeholders in university education, to know who should be responsible for quality assurance of university education in Nigeria. Descriptive research of survey design was employed in the study. The population consisted of all public university staff members, students and the employers of Nigerian university…

  4. MCNP trademark Software Quality Assurance plan

    International Nuclear Information System (INIS)

    Abhold, H.M.; Hendricks, J.S.

    1996-04-01

    MCNP is a computer code that models the interaction of radiation with matter. MCNP is developed and maintained by the Transport Methods Group (XTM) of the Los Alamos National Laboratory (LANL). This plan describes the Software Quality Assurance (SQA) program applied to the code. The SQA program is consistent with the requirements of IEEE-730.1 and the guiding principles of ISO 900

  5. Operations quality assurance for nuclear power plants

    International Nuclear Information System (INIS)

    1987-01-01

    This standard covers the quality assurance of all activities concerned with the operation and maintenance of plant equipment and systems in CANDU-based nuclear power plants during the operations phase, the period between the completion of commissioning and the start of decommissioning

  6. Quality Assurance in Higher Education in Zimbabwe

    Science.gov (United States)

    Garwe, Evelyn Chiyevo

    2014-01-01

    The purpose of this paper is to furnish local and global stakeholders with detailed information regarding the development and current status of quality assurance in the Zimbabwean higher education sector. The study used document analysis, observation and interviews with key informants as sources of data. This paper addresses the dearth of…

  7. Software quality assurance plan for GCS

    Science.gov (United States)

    Duncan, Stephen E.; Bailey, Elizabeth K.

    1990-01-01

    The software quality assurance (SQA) function for the Guidance and Control Software (GCS) project which is part of a software error studies research program is described. The SQA plan outlines all of the procedures, controls, and audits to be carried out by the SQA organization to ensure adherence to the policies, procedures, and standards for the GCS project.

  8. Quality Assurance in Distance and Open Learning

    Science.gov (United States)

    Mahafzah, Mohammed Hasan

    2012-01-01

    E-learning has become an increasingly important teaching and learning mode in educational institutions and corporate training. The evaluation of E-learning, however, is essential for the quality assurance of E-learning courses. This paper constructs a three-phase evaluation model for E-learning courses, which includes development, process, and…

  9. Endorectal high dose rate brachytherapy quality assurance

    International Nuclear Information System (INIS)

    Devic, S.; Vuong, T.; Evans, M.; Podgorsak, E.

    2008-01-01

    We describe our quality assurance method for preoperative high dose rate (HDR) brachytherapy of endorectal tumours. Reproduction of the treatment planning dose distribution on a daily basis is crucial for treatment success. Due to the cylindrical symmetry, two types of adjustments are necessary: applicator rotation and dose distribution shift along the applicator axis. (author)

  10. Assuring Quality in Online Course Delivery

    Science.gov (United States)

    Matuga, Julia M.; Wooldridge, Deborah G.; Poirier, Sandra

    2011-01-01

    This paper examines the critical issue of assuring quality online course delivery by examining four key components of online teaching and learning. The topic of course delivery is viewed as a cultural issue that permeates processes from the design of an online course to its evaluation. First, the authors examine and review key components of and…

  11. Role of quality assurance in reactor safety

    International Nuclear Information System (INIS)

    Roedel, J.A.

    1975-01-01

    A quality assurance program based on common sense, designed to accomplish what is reasonable and necessary, giving proper consideration to safety and economics can be an effective and essential management tool for the design, construction and operation of safe and economical nuclear power plants

  12. Quality assurance in materials and construction

    Science.gov (United States)

    2007-06-01

    This review is a product of the FHWA 2006, National Review Program (NRP). Quality Assurance (QA) was selected for review in 2006 because the program was ranked as one of the top five areas of interest for review by FHWA. Over the last 10 years an ave...

  13. Quality assurance measures in interventional radiology

    International Nuclear Information System (INIS)

    Heuser, L.

    1999-01-01

    The quality assurance of treatment measures is legally required but as yet not generally established in practice. For interventional radiology, the introduction of quality assurance for PTA of arteries of the lower limbs is planned for January 1999. It is reasonable to subject at least the most important and/or most frequently performed interventions to quality management. In the present article, the term quality in the management of diseases is defined and the system of total quality management discussed at the levels structure, process, and results. For its application, parameters of quality measurement in the form of standards, criteria, and characteristic values are necessary and must be laid down by a team of experts on the basis of subjective experience and/or results in the literature. Practical quality assurance takes place not only within a clinic but also externally by comparison with other centers. Data collection and evaluation requires high-performance software that will be continuously improved, expanded, and adapted to current needs during regular meetings between the various users. (orig.) [de

  14. 222-S laboratory quality assurance plan

    International Nuclear Information System (INIS)

    Meznarich, H.K.

    1995-01-01

    This document provides quality assurance guidelines and quality control requirements for analytical services. This document is designed on the basis of Hanford Analytical Services Quality Assurance Plan (HASQAP) technical guidelines and is used for governing 222-S and 222-SA analytical and quality control activities. The 222-S Laboratory provides analytical services to various clients including, but not limited to, waste characterization for the Tank Waste Remediation Systems (TWRS), waste characterization for regulatory waste treatment, storage, and disposal (TSD), regulatory compliance samples, radiation screening, process samples, and TPA samples. A graded approach is applied on the level of sample custody, QC, data verification, and data reporting to meet the specific needs of the client

  15. Revision of Krsko NPP Quality Assurance Plan

    International Nuclear Information System (INIS)

    Biscan, R.; Fifnja, I.; Kavsek, D.

    2012-01-01

    International standards from nuclear power plant operation area are being frequently upgraded and revised in accordance with the continuous improvement philosophy. This philosophy applies also to the area of Quality Assurance, which has also undergone significant improvement since the early 1950s. Besides just nuclear industry, there are also other international quality standards that are being continuously developed and revised, bringing needs for upgrades also in the nuclear application. Since the beginning of Krsko NPP construction, the overall Quality Assurance program and its applicable procedures were in place to assure that all planned and systematic actions necessary to provide adequate confidence that an item or service will satisfy given requirements to quality, are in place. The overall requirements for quality as one of the major objectives for Krsko NPP operation are also set forth in the Updated Safety Analyses Report, the document that serves as a base for operating license. During more than 30 years of Krsko NPP operation, the quality requirements and related documents were revised and upgraded in several attempts. The latest revision 6 of QD-1, Quality Assurance Plan was issued during the year 2011. The bases for the revision were: Changes of the Slovenian regulatory requirements (ZVISJV, JV5, JV9?), Changes of Krsko NPP licensing documents (USAR section 13?), SNSA inspection requirements, Changes of international standards (IAEA, ISO?), Conclusions of first PSR, Implementation of ISO standards in Krsko NPP (ISO14001, ISO17025), Changes of plant procedures, etc. One of the most obvious changes was the enlargement of the QA Plan scope to cover interdisciplinary areas defined in the plant management program MD-1, such as Safety culture, Self-assessment, Human performance, Industrial Safety etc. The attachment of the QA Plan defining relationships between certain standards was also updated to provide matrix for better correlation of requirements of

  16. Quality assurance for electronic portal imaging devices

    International Nuclear Information System (INIS)

    Shalev, S.; Rajapakshe, R.; Gluhchev, G.; Luchka, K.

    1997-01-01

    Electronic portal imaging devices (EPIDS) are assuming an ever-increasing role in the verification of radiation treatment accuracy. They are used both in a passive capacity, for the determination of field displacement distributions (''setup errors''), and also in an active role whereby the patient setup is corrected on the basis of electronic portal images. In spite of their potential impact on the precision of patient treatment, there are few quality assurance procedures available, and most of the EPIDS in clinical use are subject, at best, to only perfunctory quality assurance. The goals of this work are (a) to develop an objective and reproducible test for EPID image quality on the factory floor and during installation of the EPID on site; (b) to provide the user with a simple and accurate tool for acceptance, commissioning, and routine quality control; and (c) to initiate regional, national and international collaboration in the implementation of standardized, objective, and automated quality assurance procedures. To this end we have developed an automated test in which a simple test object is imaged daily, and the spatial and contrast resolution of the EPID are automatically evaluated in terms of ''acceptable'', ''warning'' and ''stop'' criteria. Our experience over two years shows the test to be highly sensitive, reproducible, and inexpensive in time and effort. Inter-institutional trials are under way in Canada, US and Europe which indicate large variations in EPID image quality from one EPID to another, and from one center to another. We expect the new standardized quality assurance procedure to lead to improved, and consistent image quality, increased operator acceptance of the technology, and agreement on uniform standards by equipment suppliers and health care agencies. (author)

  17. Quality assurance or neo-imperialism

    DEFF Research Database (Denmark)

    Adriansen, Hanne Kirstine; Madsen, Lene Møller

    intention to do the opposite. Hence, we want to address how to make quality assurance can be made without imposing Western epistemologies. We call for an appreciation of different knowledges instead of mainstreaming in the name of internationalisation and globalisation. Capacity building of higher education...... in developing countries should ensure a broader perspective of educational quality in order not to lose knowledge diversity and wisdom....

  18. Definition of a material's quality assurance level

    International Nuclear Information System (INIS)

    Fride, B.

    1990-01-01

    The architecture of expert system COIN (French acronym for classification of Operation Tools) is presented. The system was developed for providing assistance in the determination of the quality level required by the operation tools and their components. Those tools are applied in the maintenance operations in the nuclear power plants and are classified under a Quality Assurance procedure. The characteristics of COIN, its influence on a problem solving method, and the steps of the system's development are summarized [fr

  19. The quality cost loop in quality assurance

    International Nuclear Information System (INIS)

    Grabowski, S.P.

    1979-01-01

    A system to determine quality cost is described which solves two major problems: - Determination of quality cost with sufficient accuracy in consideration of rentability - Implementation of quality cost in cost accounting. (RW) [de

  20. Quality assurance of radiation therapy machines

    International Nuclear Information System (INIS)

    Francois, P.

    2002-01-01

    Due to the modifications of components, to unexpected breakage of elements or to electronic dysfunctions, the performance of radiotherapy machines may decrease with age. Quality Assurance procedures and maintenance program are necessary to guarantee the performances. For linear accelerators, modus operandi of control tests and their frequency are based on regulations and recommendations widely published, that are presented here. Concerning accessories, especially those recently developed (multi-leaf collimators, dynamic wedges,...), recommendations remains to be defined. Simple tests are proposed. Concerning numerical imaging systems, widely used for three dimensional dosimetry, image quality and geometry controls must be performed with fantom tests. For portal imaging, a quality assurance program is proposed. A strict and complete Quality Assurance program is essential to guarantee quality and safety of the treatment. A regular control of linear accelerator is one of the important component of this program. It suppose the implementation of permanent tests procedures, periodically modified following technological progresses and treatment techniques. Measurements must be sensible to variations below the tolerance level defined during the installation process. The analysis of the variations of measurements with time are an objective criterion of quality. (author)

  1. UMTRA project technical assistance contractor quality assurance implementation plan

    International Nuclear Information System (INIS)

    1994-03-01

    The Uranium Mill Tailings Remedial Action (UMTRA) Project Technical Assistance contractor (TAC) Quality Assurance Implementation Plan (QAIP) outlines the primary requirements for integrating quality functions for TAC technical activities applied to the surface and ground water phases of the UMTRA Project. The QAIP is subordinate to the latest issue of the UMTRA Project TAC Quality Assurance Program Plan (QAPP) (DOE, 1993a), which was developed using US Department of Energy (DOE) Order 5700.6C quality assurance (QA) criteria. The QAIP addresses technical aspects of the TAC UMTRA Project surface and ground water programs. All QA issues in the QAIP shall comply with requirements contained in the TAC QAPP (DOE, 1933a). Because industry standards for data acquisition and data control are not addressed in DOE Order 5700.6C, the QAIP has been formatted to the 14 US Environmental Protection Agency (EPA) Comprehensive Environmental Response, Compensation, and Liability Act (CERCLA) QA requirements. DOE Order 5700.6C criteria that are not contained in the CERCLA requirements are added to the QAIP as additional requirements in Sections 15.0 through 18.0. Project documents that contain CERCLA requirements and 5700.6 criteria shall be referenced in this document to avoid duplication. Referenced documents are not included in this QAIP but are available through the UMTRA Project Document Control Center

  2. Nuclear medicine quality assurance program in Argentina

    International Nuclear Information System (INIS)

    Levi de Cabrejas, Mariana; Arashiro, Jorge G.; Giannone, Carlos A.

    1999-01-01

    A two steps program has been implemented: the first one is the quality control of the equipment and the second one the development of standard procedures for clinical studies of patients. A training program for doctors and technicians of the nuclear medicine laboratories was carried out. Workshops on instrumentation and quality assurance in nuclear medicine have been organized in several parts of the country. A joint program of the CNEA and the University of Buenos Aires has trained medical physicists. A method has been established to evaluate the capability of the laboratories to produce high quality images and to follow up the implementation of the quality control program

  3. Prototype international quality assurance program

    International Nuclear Information System (INIS)

    Broadway, J.A.; Chambless, D.A.; Sapozhnikov, Yu.A.; Kalmykov, S.N.

    1998-01-01

    The international community presently lacks the ability to determine the quality and credibility of environmental measurements that is required to make sound decisions in matters related to international security, public health, and investment-related considerations. The ultimate goal of the work described in this article is to develop a credible information base including measurement capability for determination of environmental contamination and the potential for proliferation of material components of chemical or nuclear weapons. This study compared the accuracy obtained by six Russian and six U.S. laboratories for samples representative of classes of trace metals, dioxing-furans, and radioactive substances. The results obtained in this work indicate that current estimates for laboratory accuracy are likely overly optimistic. The weaknesses discovered by this prototype U.S. - Russia study also exist within the broader international community of laboratories. Further work is proposed to address the urgent need for the international community to improve performance evaluations for analytical measurements. (author)

  4. Chemical analysis quality assurance at the ICPP

    International Nuclear Information System (INIS)

    Hand, R.L.

    1990-01-01

    This document discusses the chemical analysis quality assurance program at the ICPP which involves records management, analytical methods quality control, analysis procedures and training and qualification. Since 1979, the major portion of the quality assurance program has been implemented on a central analytical computer system. The individual features provided by the system are storage, retrieval, and search capabilities over all general request and sample analysis information, automatic method selection for all process streams, automation of all method calculations, automatic assignment of bias and precision estimates at all analysis levels, with-method-use requalification, untrained or unqualified analyst method lockout, statistical testing of all process stream results for replicate agreement, automatic testing of process results against pre- established operating, safety, or failure limits at varying confidence levels, and automatic transfer and report of all analysis data plus all statistical testing to the Production Department

  5. [Quality assurance in occupational health services].

    Science.gov (United States)

    Michalak, J

    1996-01-01

    The general conditions influencing the quality assurance and audit in Polish occupational health services are presented. The factors promoting or hampering the implementation of quality assurance and audits are also discussed. The major influence on the transformation of Polish occupational health services in exorted by employers who are committed to cover the costs of the obligatory prophylactic examination of their employees. This is the factor which also contributes to the improvement of quality if services. The definitions of the most important terms are reviewed to highlight their accordance with the needs of occupational health services in Poland. The examples of audit are presented and the elements of selected methods of auditing are suggested to be adopted in Poland.

  6. Inverters for photovoltaics: quality assurance

    International Nuclear Information System (INIS)

    Graf, J.D.; Haeberlin, H.

    2000-01-01

    This project-overview published by the University of Applied Science in Burgdorf, Switzerland, looks back at the history of the university's testing laboratory for inverters for use in photovoltaic installations and discusses the work done there. After its move from Oberburg to Burgdorf in the early nineties, the laboratory was equipped to provide testing facilities for inverters up to 60 kW. Additions have been made to the infrastructure since then to facilitate the testing of various types of inverter produced in Switzerland and other countries. The measurements that can be carried out, including DC-AC conversion efficiency, harmonics, RF interference, islanding, sensitivity to tele-control signals, turn-on power and operating voltage range are described. The improvement in the quality of the inverters tested is discussed and the importance of continued testing as new manufacturers come onto the market is emphasised. The installation of further testing equipment, such as a 25 kW solar generator simulator and apparatus for the testing of maximum-power-tracking efficiency is discussed

  7. Quality assurance: image production and film quality

    International Nuclear Information System (INIS)

    Abd Aziz Mhd Ramli

    2004-01-01

    The contents of this chapter are follows - Factors Affecting Image Quality and Patient Dose: Quality Control in Diagnostic Radiology, Mechanical Safety, Electrical Safety, Radiation Protection, Performance and Safety Standard, Calibration of QC Test Tools

  8. Quality Assurance of Quality Assurance Agencies from an Asian Perspective: Regulation, Autonomy and Accountability

    Science.gov (United States)

    Hou, Angela Yung-Chi; Ince, Martin; Tsai, Sandy; Chiang, Chung Lin

    2015-01-01

    As quality guardians of higher education, quality assurance agencies are required to guarantee the credibility of the review process and to ensure the objectivity and transparency of their decisions and recommendations. These agencies are therefore expected to use a range of internal and external approaches to prove the quality of their review…

  9. Management control and quality assurance during plant operation

    International Nuclear Information System (INIS)

    Modemann, G.; Ettemeyer, R.; Stephan, W.

    1980-01-01

    The present paper deals with basic aspects of quality assurance for owners of nuclear power plants, with quality assurance for plant operation and with consequences from KTA regulatory requirements. (RW)

  10. Quality assurance programs from laboratories offering radiological protection services

    International Nuclear Information System (INIS)

    Marrero Garcia, M.; Prendes Alonso, M.; Jova Sed, L.; Morales Monzon, J.A.

    1998-01-01

    The implementation of an adequate program for quality assurance in institutions servicing radiological protection programs will become an additional tool to achieve security targets included in that program. All scientific and technical services offered by CPHR employ quality assurance systems

  11. Quality Assurance Tracking System - R7 (QATS-R7)

    Data.gov (United States)

    U.S. Environmental Protection Agency — This is metadata documentation for the Quality Assurance Tracking System - R7, an EPA Region 7 resource that tracks information on quality assurance reviews. Also...

  12. University Administrators' Conceptions of Quality and Approaches to Quality Assurance

    Science.gov (United States)

    Goff, Lori

    2017-01-01

    As the quality of university education garners increasingly more interest in both the public and in the literature, and as quality assurance (QA) processes are developed and implemented within universities around the world, it is important to carefully consider what is meant by the term quality. This study attempts to add to the literature…

  13. Principles of spiral CT: III. Quality assurance

    International Nuclear Information System (INIS)

    Suess, C.; Kalender, W.A.

    1998-01-01

    Since its introduction in 1989 spiral CT has gained wide clinical acceptance and meanwhile it covers a large range of CT applications. This new technology, however, has not yet been recognized and acknowledged in the national or international regulations on scanner quality assurance (QA) programs. The conventional QA procedures should be extended to check the distribution of resolution and noise within the image plane. Imaging performance in the axial direction constitutes one of the major advantages of spiral scanning. Therefore, the slice sensitivity profiles and the spatial and low-contrast resolution along the z-axis have to be assessed. The high demands on table feed accuracy require additional tests. We suggest phantoms and procedures to check and quantify these parameters. Thereby, we hope to support the ongoing discussion about spiral CT quality assurance. (orig.) [de

  14. Quality assurance and demolition: 2008 symposium

    International Nuclear Information System (INIS)

    Schartmann, F.; Thierfeldt, S.

    2008-01-01

    The 'Quality Assurance and Demolition Symposium, which has become a tradition established jointly by Applus RTD Deutschland GmbH (formerly compra GmbH) and Brenk Systemplanung GmbH, Aachen, was held also in 2008 with the focus on quality assurance and the demolition of nuclear facilities. The conference began with a series of lectures on knowledge and document management in general, and the use of document management systems in the nuclear field in particular. The evening lecture was presented by Axel Weis (Karlsruhe Research Center) on 'Competence Preservation in Nuclear Technology'. The 24 technical papers presented on the next 2 days of the symposium dealt with non-destructive materials testing and with special problems of radiation protection, demolition, and waste management. In 2009, the meeting will cover similar main topics and will again be held in an interesting environment, perhaps in combination with a tour of a demolition project. (orig.)

  15. Quality assurance of nuclear medicine computer software

    International Nuclear Information System (INIS)

    Cradduck, T.D.

    1986-01-01

    Although quality assurance activities have become well established for the hardware found in nuclear medicine little attention has been paid to computer software. This paper outlines some of the problems that exist and indicates some of the solutions presently under development. The major thrust has been towards establishment of programming standards and comprehensive documentation. Some manufacturers have developed installation verification procedures which programmers are urged to use as models for their own programs. Items that tend to cause erroneous results are discussed with the emphasis for error detection and correction being placed on proper education and training of the computer operator. The concept of interchangeable data files or 'software phantoms' for purposes of quality assurance is discussed. (Author)

  16. Clinical quality assurance in radiation oncology

    International Nuclear Information System (INIS)

    Anon.

    1991-01-01

    A quality assurance program in radiation oncology monitors and evaluates any departmental functions which have an impact on patient outcome. The ultimate purpose of the program is to maximize health benefit to the patient without a corresponding increase in risk. The foundation of the program should be the credo: at least do no harm, usually do some good and ideally realize the greatest good. The steep dose response relationships for tumor control and complications require a high degree of accuracy and precision throughout the entire process of radiation therapy. It has been shown that failure to control local disease with radiation may result in decreased survival and may increase the cost of care by a factor of 3. Therefore, a comprehensive quality assurance program which seeks to optimize dose delivery and which encompasses both clinical and physics components, is needed

  17. Quality assurance for health and environmental chemistry: 1986

    International Nuclear Information System (INIS)

    Gautier, M.A.; Gladney, E.S.; Moss, W.D.; Phillips, M.B.; O'Malley, B.T.

    1987-11-01

    This report documents the continuing quality assurance efforts of the Health and Environmental Chemistry Group at the Los Alamos National Laboratory. The philosophy, methodology, and computing resources used by the quality assurance program to encompass the diversity of analytical chemistry practiced in the group are described. Included in the report are all quality assurance reference materials used, along with their certified or consensus concentrations, and all analytical chemistry quality assurance measurements made by HSE-9 during 1986. 27 refs., 3 figs

  18. Quality Assurance/Quality Control Jobs

    Science.gov (United States)

    Fanslau, Melody; Young, Janelle

    The production of a quality and safe food product is essential to the success of any food manufacturing facility. Because of this great importance, a career in quality can be extremely rewarding. Without happy customers willing to buy a product, a company would not be able to survive. Quality issues such as foreign objects, spoiled or mislabeled product, failure to meet net weight requirements, or a recall can all turn customers away from buying a product. The food industry is a customer-driven market in which some consumers are brand loyal based on a history of high quality or in which a single bad experience with a product will turn them away for a lifetime. With this said, the main role of a quality department is to help ensure that quality issues such as these are eliminated or kept to a minimum to maintain or increase the number of customers purchasing their product.

  19. Review of SKB's Quality Assurance Programme

    International Nuclear Information System (INIS)

    Baldwin, Tamara D.; Hicks, Timothy W.

    2009-06-01

    SKB is preparing a license application for the construction of a final repository for spent nuclear fuel in Sweden. This application will be supported by the safety assessment SR-Site for the post-closure phase. The assessment of long-term safety is based on a broad range of experimental results from laboratory scale, intermediate scale and up to full scale experiments. It is essential that there is a satisfactory level of assurance that experiments have been carried of with sufficient quality, so that results can be considered to be reliable within the context of their use in safety assessment. SSM has initiated a series of reviews of SKB's methods of quality assurance and their implementation. This project includes reviews of the quality assurance (QA) procedures and instructions that have been prepared for the SR-Site assessment as well as reviews of QA implementation at the canister and buffer/backfill laboratories in Oskarshamn, Sweden. The purpose of this project is to assess SKB's quality assurance with the view of providing a good basis for subsequent quality reviews in the context of future licensing. This has been achieved by examination of a number of SKB experiments using a check list, visits to the relevant facilities, and meetings with contractors and a few members of the SKB staff. Overall, the reviewed set of QA documents and instructions do provide reasonably comprehensive coverage of quality-affecting issues relating to the SR-Site safety assessment and, if implemented correctly, will generate confidence in the reliability of the safety assessment results. The results show that the efforts involving quality assurance are increasing within the SKB programme and in general appear to be satisfactory for ongoing experiments and measurements. However, progress in development of the QA documents and instructions has been relatively recent and it may be difficult for these to be fully implemented in the short period remaining before the planned licence

  20. The chaos theory and the quality assurance

    International Nuclear Information System (INIS)

    Aguilar, Omar; Domech More, Jesus

    1999-01-01

    In the present paper we suggest the importance that the new science of chaos offers in the analysis,design and improvement processes in the production of gamma shielding devices as part of the quality assurance system. A brief analysis of the influence of the errors of measures, the interactions between the process and its environment in determining of the basic behaviour of the process and its stability is done.(author)

  1. On the development of quality assurance

    DEFF Research Database (Denmark)

    Andersen, Jens

    2014-01-01

    Contemporary research in quality assurance indicates that large uncertainties observed in interlaboratory comparisons to a large extent originate from a lack of competence of laboratory staff. This explanation is challenged by the present article for which six technologies and multiple series of ...... of uncertainties of certified reference materials (CRMs) gave results that differed significantly from those in the certificates of the CRMs. (C) 2014 Elsevier B.V. All rights reserved....

  2. The grading management of the quality assurance

    International Nuclear Information System (INIS)

    Ma Xiaozheng; Han Shufang; Yu Bei; Tian Xuehang

    2009-01-01

    This paper introduces the quality assurance grading management of the items, services and technology process on nuclear power plants (nuclear island, conventional island, BOP), such as the requirements and aim in the related code, guide, technical document, the requirements for the related units, the grading principle and grading, the considering method for the differences of QA requirements of the each QA grand, as well as the status and propositions in the QA grading management in China. (authors)

  3. The quality assurance program at K & S

    Energy Technology Data Exchange (ETDEWEB)

    Slowey, T.W. [AAPM Accredited Dosimetry Calibration Laboratory, Nashville, TN (United States)

    1993-12-31

    K & S operates the largest and one of the most comprehensive Accredited Dosimetry Calibration Laboratories (ADCLs) in the American Association of Physicists in Medicine (AAPM) secondary laboratory system. It offers calibrations covering energies from Grenz-Ray (0.03-mm Al) to cesium-137 and cobalt-60, brachytherapy source and well chamber calibrations for low-activity sources, and, recently, high-dose-rate iridium-192. The present Quality Assurance (QA) program at K & S began with the AAPM Guidelines for Accreditation (Task Group No. 22 and No. 3, 1989) and grew over the past 10 years to include all aspects of providing a private, self-supporting calibration service from a free-standing independent facility. Some aspects of the QA program were prompted by the requirements of the nuclear power industry while other parts were from national consensus standards or the experiences of staff. Redundancy and teamwork are the most important characteristics of this QA program. K & S has participated in a National Institute of Standards and Technology (NIST) measurement quality assurance (MQA) program since 1982, and, in recent years, an ADCL intralaboratory intercomparison was conducted by Task Group 3 of the Radiation Therapy Committee of the AAPM. One measure of the credibility of a QA program is consistent performance on the MQA program and the ADCL intercomparisons over the past 10 years. An equally important measure of the ability of a program to assure quality results is the frequency of reported errors.

  4. Application of Quality Assurance Mechanisms for Effective Library ...

    African Journals Online (AJOL)

    The main strategy used for implementation of quality assurance was integration of the library` services quality assurance agenda into the university structures and the quality assurance mechanisms available and used in Nigerian university libraries were programme accreditation and benchmarking of library systems.

  5. Quality Assurance of Assessment and Moderation Discourses Involving Sessional Staff

    Science.gov (United States)

    Grainger, Peter; Adie, Lenore; Weir, Katie

    2016-01-01

    Quality assurance is a major agenda in tertiary education. The casualisation of academic work, especially in teaching, is also a quality assurance issue. Casual or sessional staff members teach and assess more than 50% of all university courses in Australia, and yet the research in relation to the role sessional staff play in quality assurance of…

  6. 42 CFR 441.474 - Quality assurance and improvement plan.

    Science.gov (United States)

    2010-10-01

    ... 42 Public Health 4 2010-10-01 2010-10-01 false Quality assurance and improvement plan. 441.474... improvement plan. (a) The State must provide a quality assurance and improvement plan that describes the State... pursue opportunities for system improvement. (b) The quality assurance and improvement plan shall also...

  7. Quality assurance program plan for radionuclide airborne emissions monitoring

    International Nuclear Information System (INIS)

    Boom, R.J.

    1995-12-01

    This Quality Assurance Program Plan identifies quality assurance program requirements and addresses the various Westinghouse Hanford Company organizations and their particular responsibilities in regards to sample and data handling of radiological airborne emissions. This Quality Assurance Program Plan is prepared in accordance with and to written requirements

  8. Quality Assurance in Postgraduate Education. ENQA Workshop Report 12

    Science.gov (United States)

    Bitusikova, Alexandra; Bohrer, Janet; Borosic, Ivana; Costes, Nathalie; Edinsel, Kerim; Hollander, Karoline; Jacobsson, Gunilla; Jakopovic, Ivan Filip; Kearney, Mary-Louise; Mulder, Fred; Negyesi, Judith; Pietzonka, Manuel

    2010-01-01

    The present report follows an ENQA (European Association for Quality Assurance in Higher Education) Workshop on Quality Assurance and Postgraduate Education, hosted by the Romanian Agency for Quality Assurance in Higher Education (ARACIS) in Brasov, Romania on 12-13 March 2009. The workshop was an excellent opportunity for ENQA members to exchange…

  9. Quality Assurance in Transnational Higher Education. ENQA Workshop Report 11

    Science.gov (United States)

    Bennett, Paul; Bergan, Sjur; Cassar, Daniela; Hamilton, Marlene; Soinila, Michele; Sursock, Andree; Uvalic-Trumbic, Stamenka; Williams, Peter

    2010-01-01

    The present report is the product of an ENQA (European Association for Quality Assurance in Higher Education) Bologna Seminar "Quality Assurance in Transnational Education: from words to action" hosted by the Quality Assurance Agency (QAA, UK) in London in December, 2008. The seminar discussed the current trends in Transnational…

  10. Quality assurance requirements in various codes and standards

    International Nuclear Information System (INIS)

    Shaaban, H.I.; EL-Sayed, A.; Aly, A.E.

    1987-01-01

    The quality assurance requirements in various countries and according to various international codes and standards are presented, compared and critically discussed. Cases of developing countries are also discussed, and the use of IAEA code of practice and other codes for quality assurance in these countries is reviewed. Recommendations are made regarding the quality assurance system to be applied for Egypt's nuclear power plants

  11. 48 CFR 12.208 - Contract quality assurance.

    Science.gov (United States)

    2010-10-01

    ... 48 Federal Acquisition Regulations System 1 2010-10-01 2010-10-01 false Contract quality assurance... Items 12.208 Contract quality assurance. Contracts for commercial items shall rely on contractors' existing quality assurance systems as a substitute for Government inspection and testing before tender for...

  12. 21 CFR 58.35 - Quality assurance unit.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 1 2010-04-01 2010-04-01 false Quality assurance unit. 58.35 Section 58.35 Food... LABORATORY PRACTICE FOR NONCLINICAL LABORATORY STUDIES Organization and Personnel § 58.35 Quality assurance unit. (a) A testing facility shall have a quality assurance unit which shall be responsible for...

  13. Operational excellence (six sigma) philosophy: Application to software quality assurance

    Energy Technology Data Exchange (ETDEWEB)

    Lackner, M.

    1997-11-01

    This report contains viewgraphs on operational excellence philosophy of six sigma applied to software quality assurance. This report outlines the following: goal of six sigma; six sigma tools; manufacturing vs administrative processes; Software quality assurance document inspections; map software quality assurance requirements document; failure mode effects analysis for requirements document; measuring the right response variables; and questions.

  14. Quality assurance applied to an environmental surveillance program

    International Nuclear Information System (INIS)

    Oakes, T.W.; Shank, K.E.; Eldridge, J.S.

    1977-01-01

    A discussion of a quality assurance program applied to environmental surveillance activities is presented. This includes the philosophy and concepts of quality assurance, along with a detailed assessment of the sources of uncertainty in a monitoring program. The role management must play for a successful program is also discussed, and the quality assurance program implemented at Oak Ridge National Laboratory is presented

  15. Development of an Instructional Quality Assurance Model in Nursing Science

    Science.gov (United States)

    Ajpru, Haruthai; Pasiphol, Shotiga; Wongwanich, Suwimon

    2011-01-01

    The purpose of this study was to develop an instructional quality assurance model in nursing science. The study was divided into 3 phases; (1) to study the information for instructional quality assurance model development (2) to develop an instructional quality assurance model in nursing science and (3) to audit and the assessment of the developed…

  16. Quality Assurance in Higher Education: Proposals for Consultation.

    Science.gov (United States)

    Higher Education Funding Council for England, Bristol.

    This document sets out for consultation proposals for a revised method for quality assurance of teaching and learning in higher education. The proposals cover: (1) the objectives and principles of quality assurance; (2) an approach to quality assurance based on external audit principles; (3) the collection and publication of information; (4)…

  17. Quality assurance in Hanford site defense waste operations

    International Nuclear Information System (INIS)

    Wojtasek, R.D.

    1989-01-01

    This paper discusses quality assurance as an integral part of conducting waste management operations. The storage, treatment, and disposal of radioactive and non- radioactive hazardous wastes at Hanford are described. The author reports that quality assurance programs provide confidence that storage, treatment, and disposal facilities and systems perform as intended. Examples of how quality assurance is applied to Hanford defense waste operations are presented

  18. Health equity monitoring for healthcare quality assurance.

    Science.gov (United States)

    Cookson, R; Asaria, M; Ali, S; Shaw, R; Doran, T; Goldblatt, P

    2018-02-01

    Population-wide health equity monitoring remains isolated from mainstream healthcare quality assurance. As a result, healthcare organizations remain ill-informed about the health equity impacts of their decisions - despite becoming increasingly well-informed about quality of care for the average patient. We present a new and improved analytical approach to integrating health equity into mainstream healthcare quality assurance, illustrate how this approach has been applied in the English National Health Service, and discuss how it could be applied in other countries. We illustrate the approach using a key quality indicator that is widely used to assess how well healthcare is co-ordinated between primary, community and acute settings: emergency inpatient hospital admissions for ambulatory care sensitive chronic conditions ("potentially avoidable emergency admissions", for short). Whole-population data for 2015 on potentially avoidable emergency admissions in England were linked with neighborhood deprivation indices. Inequality within the populations served by 209 clinical commissioning groups (CCGs: care purchasing organizations with mean population 272,000) was compared against two benchmarks - national inequality and inequality within ten similar populations - using neighborhood-level models to simulate the gap in indirectly standardized admissions between most and least deprived neighborhoods. The modelled inequality gap for England was 927 potentially avoidable emergency admissions per 100,000 people, implying 263,894 excess hospitalizations associated with inequality. Against this national benchmark, 17% of CCGs had significantly worse-than-benchmark equity, and 23% significantly better. The corresponding figures were 11% and 12% respectively against the similar populations benchmark. Deprivation-related inequality in potentially avoidable emergency admissions varies substantially between English CCGs serving similar populations, beyond expected statistical

  19. Quality assurance of computed tomography (CT) scanners

    International Nuclear Information System (INIS)

    Sankaran, A.; Sanu, K.K. . Email : a_sankaran@vsnl.com

    2004-01-01

    This article reviews the present status of research work and development of various test objects, phantoms and detector/instrumentation systems for quality assurance (QA) of computed tomography (CT) scanners, carried out in advanced countries, with emphasis on similar work done in this research centre. CT scanner is a complex equipment and routine quality control procedures are essential to the maintenance of image quality with optimum patient dose. Image quality can be ensured only through correlation between prospective monitoring of system components and tests of overall performance with standard phantoms. CT examinations contribute a large share to the population dose in advanced countries. The unique dosimetry problems in CT necessitate special techniques. This article describes a comprehensive kit developed indigenously for the following QA and type approval tests as well as for research studies on image quality/dosimetry on CT scanners

  20. Quality assurance in dosimetry and treatment planning

    International Nuclear Information System (INIS)

    Cunningham, J.R.

    1984-01-01

    The considerations of tissue response to radiation absorbed dose suggest a need for an accuracy of +/-5% in its delivery. This is very demanding and its regular achievement requires careful quality control. There are three distinct phases to the delivery of the planned treatment: calibration of the radiation beam in a reference situation, calculation of the dose distribution for a patient relative to the reference dose and the delivery of the radiation to the patient as planned. Each has distinctly different quality assurance requirements and must be diligently observed if the desired accuracy is to be achieved

  1. Quality assurance in nuclear medicine radioactivity measurements

    International Nuclear Information System (INIS)

    Sahagia, Maria; Razdolescu Anamaria Cristina

    2007-01-01

    The paper presents some recent results of the Radionuclide Metrology Laboratory (RML) from IFIN-HH, in the assurance of quality in radioactivity measurements for nuclear medicine. Three aspects are treated: (i) Participation of the RML in the frame of the IAEA Coordinated Research Program (CRP), E 2.10.05; (ii) Improvement of the secondary standard, based on a CENTRONIC IG12/20A ionization chamber; (iii) Implementation of the quality management, according to the SR EN ISO/IEC 17025:2005. (authors)

  2. Quality Assurance Framework for Mini-Grids

    Energy Technology Data Exchange (ETDEWEB)

    Esterly, Sean; Baring-Gould, Ian; Booth, Samuel

    2017-05-04

    To address the root challenges of providing quality power to remote consumers through financially viable mini-grids, the Global Lighting and Energy Access Partnership (Global LEAP) initiative of the Clean Energy Ministerial and the U.S. Department of Energy teamed with the National Renewable Energy Laboratory (NREL) and Power Africa to develop a Quality Assurance Framework (QAF) for isolated mini-grids. The framework addresses both alternating current (AC) and direct current (DC) mini-grids, and is applicable to renewable, fossil-fuel, and hybrid systems.

  3. Quality assurance and quality control of nuclear engineering during construction phase

    International Nuclear Information System (INIS)

    Zhang Zhihua; Deng Yue; Liu Yaoguang; Xu Xianqi; Zhou Shan; Qian Dazhi; Zhang Yang

    2007-01-01

    The quality assurance (QA) and quality control (QC) is a very important work in the nuclear engineering. This paper starts with how to establish quality assurance system of nuclear engineering construction phase, then introduces several experiments and techniques such as the implementation of quality assurance program, the quality assurance and quality control of contractors, the quality surveillance and control of supervisory companies, quality assurance audit and surveillance of builders. (authors)

  4. Quality assurance program. Braun topical report 21

    International Nuclear Information System (INIS)

    1975-01-01

    The Quality Assurance (QA) policies and procedures described have been developed specifically for use in commercial nuclear projects. These policies and procedures are intended to provide assurance to Braun Management and the client that the plant will be safe, reliable, and operable, plus meet the requirements of the Nuclear Regulatory Commission, NRC. The Braun QA Manual provides QA procedures for (1) engineering and design, (2) procurement of materials, equipment, and services, and (3) construction and installation. The controls for safety-related systems established in the manual cover all phases of work from project inception to plant completion prior to operation by the owner. The manual standardizes Braun QA control procedures. These procedures are supplemented by Project QA Instructions prepared for each project. (U.S.)

  5. British standard (BS) 5750--quality assurance?

    Science.gov (United States)

    Pratt, D J

    1995-04-01

    BS5750 is the British Standard on "Quality Systems". Its equivalent in European Standards is EN29000 and in the International Standards Organisation ISO9000. This paper points out that these standards lay down formalised procedures and require documentation but do not ipso facto lead to quality assurance. The author points to the Japanese post-war industrial success as being an example of Total Quality Management within the framework provided by the philosophy of Dr. W. Edwards Deming (1988 and 1993). This philosophy on the management of "systems" to provide high quality products and services is briefly outlined. The author argues that improvement in prosthetic and orthotic services will not be reached through implementation of BS5750 but rather through radical rethinking and the adoption and application of the Deming philosophy.

  6. Measurement quality assurance for radioassay laboratories

    International Nuclear Information System (INIS)

    McCurdy, D.E.

    1993-01-01

    Until recently, the quality of U.S. radioassay laboratory services has been evaluated by a limited number of governmental measurement assurance programs (MAPs). The major programs have been limited to the U.S. Department of Energy (DOE), the U.S. Environmental Protection Agency (EPA) and the U.S. Nuclear Regulatory Commission (NRC). In 1988, an industry MAP was established for the nuclear power utility industry through the U.S. Council for Energy Awareness/National Institute of Standards and Technology (USCEA/NIST). This program functions as both a MAP for utility laboratories and/or their commercial contractor laboratories, and as a traceability program for the U.S. radioactive source manufacturers and the utility laboratories. Each of these generic MAPs has been initiated and is maintained to serve the specific needs of the sponsoring agency or organization. As a result, there is diversification in their approach, scope, requirements, and degree of traceability to NIST. In 1987, a writing committee was formed under the American National Standards Institute (ANSI) N42.2 committee to develop a standard to serve as the basis document for the creation of a national measurement quality assurance (MQA) program for radioassay laboratories in the U.S. The standard is entitled, open-quotes Measurement Quality Assurance For Radioassay Laboratories.open-quotes The document was developed to serve as a guide for MQA programs maintained for the specialized sectors of the radioassay community, such as bioassay, routine environmental monitoring, environmental restoration and waste management, radiopharmaceuticals, and nuclear facilities. It was the intent of the writing committee to develop a guidance document that could be utilized to establish a laboratory's specific data quality objectives (DQOs) that govern the operational requirements of the radioassay process, including mandated protocols and recommendations

  7. Measurement quality assurance for radioassay laboratories

    Energy Technology Data Exchange (ETDEWEB)

    McCurdy, D.E. [Yankee Atomic Environmental Laboratory, Boston, MA (United States)

    1993-12-31

    Until recently, the quality of U.S. radioassay laboratory services has been evaluated by a limited number of governmental measurement assurance programs (MAPs). The major programs have been limited to the U.S. Department of Energy (DOE), the U.S. Environmental Protection Agency (EPA) and the U.S. Nuclear Regulatory Commission (NRC). In 1988, an industry MAP was established for the nuclear power utility industry through the U.S. Council for Energy Awareness/National Institute of Standards and Technology (USCEA/NIST). This program functions as both a MAP for utility laboratories and/or their commercial contractor laboratories, and as a traceability program for the U.S. radioactive source manufacturers and the utility laboratories. Each of these generic MAPs has been initiated and is maintained to serve the specific needs of the sponsoring agency or organization. As a result, there is diversification in their approach, scope, requirements, and degree of traceability to NIST. In 1987, a writing committee was formed under the American National Standards Institute (ANSI) N42.2 committee to develop a standard to serve as the basis document for the creation of a national measurement quality assurance (MQA) program for radioassay laboratories in the U.S. The standard is entitled, {open_quotes}Measurement Quality Assurance For Radioassay Laboratories.{open_quotes} The document was developed to serve as a guide for MQA programs maintained for the specialized sectors of the radioassay community, such as bioassay, routine environmental monitoring, environmental restoration and waste management, radiopharmaceuticals, and nuclear facilities. It was the intent of the writing committee to develop a guidance document that could be utilized to establish a laboratory`s specific data quality objectives (DQOs) that govern the operational requirements of the radioassay process, including mandated protocols and recommendations.

  8. [Quality assurance and quality management in intensive care].

    Science.gov (United States)

    Notz, K; Dubb, R; Kaltwasser, A; Hermes, C; Pfeffer, S

    2015-11-01

    Treatment success in hospitals, particularly in intensive care units, is directly tied to quality of structure, process, and outcomes. Technological and medical advancements lead to ever more complex treatment situations with highly specialized tasks in intensive care nursing. Quality criteria that can be used to describe and correctly measure those highly complex multiprofessional situations have only been recently developed and put into practice.In this article, it will be shown how quality in multiprofessional teams can be definded and assessed in daily clinical practice. Core aspects are the choice of a nursing theory, quality assurance measures, and quality management. One possible option of quality assurance is the use of standard operating procedures (SOPs). Quality can ultimately only be achieved if professional groups think beyond their boundaries, minimize errors, and establish and live out instructions and SOPs.

  9. Uranium resource evaluation project quality assurance evaluation

    International Nuclear Information System (INIS)

    Grimes, J.G.

    1981-01-01

    This evaluation was conducted over an eight-month period from February 4 through October 1, 1980. During this time, field sampling was suspended for an indefinite time period while the National Uranium Resource Evaluation (NURE) Program underwent restructuring. In addition, the Uranium Resource Evaluation (URE) Project archives are being restructured. Since it is difficult to evaluate quality assurance needs of a program that is undergoing drastic change and because sections of the evaluation were well along before these changes were announced, this evaluation reflects the situation as it was during February 1980. The following quality assurance related programs are continuing to date: (1) periodic checks of field sampling procedures by the Supervising Field Geologist and the Director of Field Operations; (2) verification of field form information and laboratory analytical data verification for all geochemical surveys; (3) URE Project laboratory quality control program (all elements routinely analyzed); and (4) Ames interlaboratory quality control program (uranium only). UCC-ND was given the responsibility of conducting a Hydrogeochemical and Stream Sediment Reconnaissance (HSSR) survey in the Central United States (Illinois, Indiana, Iowa, Kansas, Michigan, Minnesota, Nebraska, North Dakota, Oklahoma, Texas, South Dakota, and Wisconsin). During 1979 and 1980, 13 detailed surveys were conducted by the URE Project in the Central and Western United States to characterize the hydrogeochemistry, stream sediment geochemistry, and/or radiometric patterns of known or potential uranium occurrences. Beginning in 1980, the HSSR surveys were modified to the Regional Hydrogeochemical and Stream Sediment (RHSS) surveys

  10. Quality assurance in the project of RECH-2 research reactor

    International Nuclear Information System (INIS)

    Goycolea Donoso, C.; Nino de Zepeda Schele, A.

    1989-01-01

    The implantation of a Quality Assurance Program for the design, supply, construction, installation, and testing of the RECH-2 research reactor, is described in this paper. The obtained results, demonstrate that a Quality Assurance Program constitutes a suitable mean to assure that the installation complies with the safety and reliability requirements. (author)

  11. Quality assurance of asthma clinical trials.

    Science.gov (United States)

    Malmstrom, Kerstin; Peszek, Iza; Al Botto; Lu, Susan; Enright, Paul L; Reiss, Theodore F

    2002-04-01

    Accuracy and repeatability of spirometry measurements are essential to obtain reliable efficacy data in randomized asthma clinical trials. We report our experience with a centralized spirometry quality assurance program that we implemented in our phase III asthma trials. Six asthma trials of 4 to 21 weeks in duration were conducted at 232 clinical centers in 31 countries. Approximately 23,100 prebronchodilator and 13,700 postbronchodilator spirometry tests were collected from 2523 adult and 336 pediatric asthmatic patients. The program used a standard spirometer (the Renaissance spirometry system) with maneuver quality messages and automated quality grading of the spirometry tests. Each clinical center transmitted spirometry data weekly to a central database, where uniform monitoring of data quality was performed and feedback was provided in weekly quality reports. Seventy-nine percent of all patients performed spirometry sessions with quality that either met or exceeded American Thoracic Society standards and improved over time. Good-quality spirometry was associated with (1) less severe asthma; (2) active treatment; (3) infrequent nocturnal awakenings; (4) age above 15 years; and (5) low body weight. Maneuver-induced bronchospasm was rare. Good-quality spirometry was observed in multicenter asthma clinical trials that employed a standard spirometer and continuous monitoring. Both within- and between-patient variability decreased. Spirometry quality improved with time as study participants and technicians gained experience.

  12. Quality Assurance in Higher Education: A Review of Literature

    Science.gov (United States)

    Ryan, Tricia

    2015-01-01

    This paper examines the literature surrounding quality assurance in global higher education. It provides an overview of accreditation as a mechanism to ensure quality in higher education, examines models of QA, and explores the concept of quality (including definitions of quality and quality assurance). In addition, this paper provides a review of…

  13. 10 CFR 71.103 - Quality assurance organization.

    Science.gov (United States)

    2010-01-01

    ... location or locations where activities are performed, the organizational structure for executing the... the organizational structure, the individual(s) assigned the responsibility for assuring effective... performing quality assurance functions must have sufficient authority and organizational freedom to— (1...

  14. Quality assurance in the manufacture of pressure components

    International Nuclear Information System (INIS)

    Knoedler, D.

    1979-01-01

    New regulations for nuclear power plants emphasize more quality assurance than it was the case in the past. Quality assurance is a management tool. During erection the quality assurance measures of the manufacturer, the main contractor and the required quality and the reliability of the proof of quality. The qualification of processes, equipment and personnel is a significant measure of quality assurance. The proof for quality assurance to be effective needs not only system-oriented audits, but also product audits aimed at quality characteristics of the product itself. The existing problems of examination techniques not optimized according to latest experience and of the large volume of documetation will persist in case the existing regulations are not adjusted according to the results of relevant studies. Furthermore the effectiveness of quality assurance is too often hampered by vague definitions of the safety objectives. (orig.) [de

  15. Quality assurance system in gamma spectrometry laboratory

    International Nuclear Information System (INIS)

    Mielnikow, A.; Michalik, B.; Chalupnik, S.; Lebecka, J.

    1996-01-01

    On basis of guidelines for development of QUALITY SYSTEM for a testing laboratory (European Standard Series EN 45000) a quality assurance system was implemented in gamma spectroscopy laboratory, where routine measurements of natural (mainly Ra-226, Ra-228, Ra-224, K-40) and artificial (mainly Cs-137 and Cs-134) isotopes are performed. We measure a variety of samples, but mainly coal, vaste rock, ashe, deposits, vegetation and air filters. Laboratory of gamma spectroscopy in Central Mining Institute has three HPGe detectors. There is one coaxial detector with 45% relative efficiency, one detector for low energy region and one detector with extended range). We have also two Ge(Li) detectors from former Czechoslovakia. Shielding is made mainly of steel (40 cm) with the interior covered with lead and copper. The electronics and software (Genie-PC) was bought at 'Canberra' and 'Silena'. The paper describes not only the system of quality assurance but also main problems met by its implementation and results of intercomparison measurements. The QAS has been introduced in 1992. In 1993 the Accreditation Certificate of Testing Laboratory for our Laboratory has been obtained from the Polish Bureau of Research and Certification as a fifth laboratory in Poland. (author)

  16. Construction quality assurance for nuclear power plants

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1983-10-01

    This Standard contains the requirements for the quality assurance program applicable to the construction phase of a nuclear power plant. This Standard covers all activities carried out for and by the owner from the receipt of components or materials on the site to their incorporation in systems or structures as required by drawings or other formal engineering information. It also covers the provision of required support activities and equipment and applies at all stages on the site as far as the testing of components or systems before they are submitted for commissioning. 2 figs.

  17. Analysis of an image quality assurance program

    International Nuclear Information System (INIS)

    Goethlin, J.H.; Alders, B.

    1985-01-01

    Reject film analysis before and after the introduction of a quality assurance program showed a 45% decrease in rejected films. The main changes in equipment and routines were: 1. Increased control of film processors and X-ray generators. 2. New film casettes and screens. 3. Decreased number of film sizes. 4. Information to and supervision of radiographing personnel. Savings in costs and increased income from an increased amount of out-patients corresponded to about 4.5% of the total cost of operating and maintaining the department. (orig.)

  18. Construction quality assurance for nuclear power plants

    International Nuclear Information System (INIS)

    1983-10-01

    This Standard contains the requirements for the quality assurance program applicable to the construction phase of a nuclear power plant. This Standard covers all activities carried out for and by the owner from the receipt of components or materials on the site to their incorporation in systems or structures as required by drawings or other formal engineering information. It also covers the provision of required support activities and equipment and applies at all stages on the site as far as the testing of components or systems before they are submitted for commissioning. 2 figs

  19. Quality assurance or neo-imperialism

    DEFF Research Database (Denmark)

    Adriansen, Hanne Kirstine; Madsen, Lene Møller

    intention to do the opposite. Hence, we want to address how to make quality assurance can be made without imposing Western epistemologies. We call for an appreciation of different knowledges instead of mainstreaming in the name of internationalisation and globalisation. Capacity building of higher education......Capacity building within higher educational institutions in so-called developing countries is gaining momentum and likewise the research field ‘international education and development’. In this paper we address the question: How can we make capacity building of higher education in developing...

  20. Spinal cord testing: auditing for quality assurance.

    Science.gov (United States)

    Marr, J A; Reid, B

    1991-04-01

    A quality assurance audit of spinal cord testing as documented by staff nurses was carried out. Twenty-five patient records were examined for accuracy of documented testing and compared to assessments performed by three investigators. A pilot study established interrater reliability of a tool that was designed especially for this study. Results indicated staff nurses failed to meet pre-established 100% standard in all categories of testing when compared with investigator's findings. Possible reasons for this disparity are discussed as well as indications for modifications in the spinal testing record, teaching program and preset standards.

  1. Quality assurance: Importance of systems and standard operating procedures.

    Science.gov (United States)

    Manghani, Kishu

    2011-01-01

    It is mandatory for sponsors of clinical trials and contract research organizations alike to establish, manage and monitor their quality control and quality assurance systems and their integral standard operating procedures and other quality documents to provide high-quality products and services to fully satisfy customer needs and expectations. Quality control and quality assurance systems together constitute the key quality systems. Quality control and quality assurance are parts of quality management. Quality control is focused on fulfilling quality requirements, whereas quality assurance is focused on providing confidence that quality requirements are fulfilled. The quality systems must be commensurate with the Company business objectives and business model. Top management commitment and its active involvement are critical in order to ensure at all times the adequacy, suitability, effectiveness and efficiency of the quality systems. Effective and efficient quality systems can promote timely registration of drugs by eliminating waste and the need for rework with overall financial and social benefits to the Company.

  2. Problems of quality assurance and quality control in diagnostic radiology

    International Nuclear Information System (INIS)

    Angerstein, W.

    1986-01-01

    Topical problems of quality assurance and quality control in diagnostic radiology are discussed and possible solutions are shown. Complex units are differentiated with reference to physicians, technicians, organization of labour, methods of examination and indication. Quality control of radiologic imaging systems should involve three stages: (1) simple tests carried out by radiologic technicians, (2) measurements by service technicians, (3) testing of products by the manufacturer and independent governmental or health service test agencies. (author)

  3. Quality Assurance for Iraqi Bottled Water Specifications

    Directory of Open Access Journals (Sweden)

    May George Kassir

    2015-10-01

    Full Text Available In this research the specifications of Iraqi drinking bottled water brands are investigated throughout the comparison between local brands, Saudi Arabia and the World Health Organization (WHO for bottled water standard specifications. These specifications were also compared to that of Iraqi Tap Water standards. To reveal variations in the specifications for Iraqi bottled water, and above mentioned standards some quality control tools are conducted for more than 33% of different bottled water brands (of different origins such as spring, purified,..etc in Iraq by investigating the selected quality parameters registered on their marketing labels. Results employing Minitab software (ver. 16 to generate X bar, and Pareto chart. It was found from X bar charts that the quality parameters of some drinking bottled water brands are not within Iraqi standards set by the “Central Agency for Standardization and Quality Control” such as pH values, Fe, Na, and Mg concentrations. While the comparison of previously mentioned standard specifications through radar chart many important issues are detected such as the absence of lower limits the whole bottled water quality parameters such as for Na and Mg also the radar chart shows that Iraqi bottled and tap water specifications are almost equal in their quality values. Also the same chart pictured the limited range of Iraqi specifications compared to that of Saudi Arabia, and WHO and the need to introduce other water specifications such as K, Na, etc. This confirms the need to improve Iraqi bottled water specifications since it was introduced on 2000. These results also highlighted the weakness of quality assurance activities since only 33 % of the investigated companies registered the whole water quality specifications as shown in Pareto chart. Other companies do not register any quality characteristics. Also certain companies should be stopped due to non-conforming specifications, yet these companies are

  4. Basic Study of Establishment of Quality Assurance Processes to Develop an Integrated Quality Assurance System for Nuclear Power Plant Construction

    International Nuclear Information System (INIS)

    Lim, Byungki; Moon, Byeongsuk; Lee, Jae Kyoung

    2014-01-01

    An integrated quality assurance system has necessitated carrying out quality assurance programs in a systematic manner because the opportunities to expand business in overseas markets have increased since the export of a nuclear power plant to UAE in 2009. In this study, we use PDCA method to systematically analyze the quality assurance procedures that were used in previous projects for constructing nuclear power plants. We reached a classification system of quality assurance processes at each phase of nuclear power plant construction by integrating similar work related to quality such as planning, design, equipment manufacturing, construction and start-up. We also established a hierarchy of quality assurance processes to develop an integrated quality assurance system as a technology goal to be developed later. To obtain most updated quality assurance activities, a quality assurance process is structured by integrating similar works analyzed from quality assurance procedures through PDCA cycle method. At the implementation phase of Hierarchy of quality processes and sequence of processes for constructing nuclear power plant are established in this study. Integrated quality assurance system is to be developed by connecting organizations as well as stakeholders such as owners, Architect engineering, suppliers, contractors, and sub-contractors to carry out assigned work efficiently

  5. Basic Study of Establishment of Quality Assurance Processes to Develop an Integrated Quality Assurance System for Nuclear Power Plant Construction

    Energy Technology Data Exchange (ETDEWEB)

    Lim, Byungki; Moon, Byeongsuk; Lee, Jae Kyoung [Korea Hydro and Nuclear Power Co. Ltd., Daejeon (Korea, Republic of)

    2014-05-15

    An integrated quality assurance system has necessitated carrying out quality assurance programs in a systematic manner because the opportunities to expand business in overseas markets have increased since the export of a nuclear power plant to UAE in 2009. In this study, we use PDCA method to systematically analyze the quality assurance procedures that were used in previous projects for constructing nuclear power plants. We reached a classification system of quality assurance processes at each phase of nuclear power plant construction by integrating similar work related to quality such as planning, design, equipment manufacturing, construction and start-up. We also established a hierarchy of quality assurance processes to develop an integrated quality assurance system as a technology goal to be developed later. To obtain most updated quality assurance activities, a quality assurance process is structured by integrating similar works analyzed from quality assurance procedures through PDCA cycle method. At the implementation phase of Hierarchy of quality processes and sequence of processes for constructing nuclear power plant are established in this study. Integrated quality assurance system is to be developed by connecting organizations as well as stakeholders such as owners, Architect engineering, suppliers, contractors, and sub-contractors to carry out assigned work efficiently.

  6. Development of a VMAT quality assurance program

    International Nuclear Information System (INIS)

    Silva, Ricardo Goulart da

    2013-01-01

    Modern radiation therapy keeps evolving and the technological changes include new imaging modalities, new patient immobilization devices and new treatment delivery systems. These advances have made it possible to reduce the dose to normal tissue structures and consequently minimize the risk of toxicity and morbidity, while allowing for dose escalation to the tumor volumes, potentially leading to improved locoregional control. Traditional IMRT techniques offer all of these features but the treatment session time is usually long, mainly for the head and neck cases. Currently, the VMAT technique is a reality in reference centers around the world. This technology has improved delivery efficiency over IMRT, decreasing the treatment application time, as this modality introduces extra degrees of freedom in the optimization process. The modulation of the radiation beams is achieved by simultaneous variation of dynamic parameters such as dose rate, gantry speed and leaves speed. The high level of complexity associated to the new treatment trends, inevitably, requires more accuracy and more rigorous quality assurance programs. The commissioning methods reported for the Varian RapidArc system were extended to an Elekta Synergy linear accelerator, using custom files built in the iComCAT software. Specific tests for the machine quality assurance are presented and also the dosimetric validation process applied to the Monaco treatment planning system. The MLC parameters, modeled by the Monte Carlo algorithm, were analyzed and the TG 119 tests were adapted for VMAT planning. In the end, a specific program developed for the VMAT technology for Elekta accelerators is presented. (author)

  7. Nuclear Technology. Course 31: Quality Assurance Practices. Module 31-7, Auditing for Quality Assurance.

    Science.gov (United States)

    Pritchard, Jim; Espy, John

    This seventh in a series of eight modules for a course titled Quality Assurance Practices describes the key features of an audit system and offers practice in carrying out tasks of the technicians. The module follows a typical format that includes the following sections: (1) introduction, (2) module prerequisites, (3) objectives, (4) notes to…

  8. Quality Assurance: Strategic Choices for Higher Education in Turkey

    Directory of Open Access Journals (Sweden)

    Mahmut ÖZER

    2011-01-01

    Full Text Available As the number of students and higher education institutions in the world increases and there is a growing difficulty in financing the higher education systems, decision-makers have begun to show more interest in quality assurance. As quality assurance is given special attention in European countries, developing countries such as Turkey are interested in importing quality assurance systems. It is not possible to set quality assurance without sensitivity toward quality and without having quality as a cultural practice. The most likely encountered quality assurance approach in the world is that the higher education institution itself is responsible for its quality. In addition, external quality assurance procedures used are based on (academic peer review rather than on bureaucratic evaluations. Moreover, there is a lively debate across the world regarding the bureaucratic regulations of the quality assurance agencies and institutions that restrict the autonomy of higher education institutions. Without taking into consideration of the existing centralized structure of the higher education system in Turkey, of meeting social demands for the higher education, and of current higher education enrollment rates, the possible establishment of a quality assurance mechanism that may have sanctions on universities in Turkey is a threat to already limited autonomy of universities and is having a risk of additional bureaucratic burden. By laying out the roles and responsibilities of Turkish Council of Higher Education, the government and universities, this article discusses policies that should be adopted regarding the quality assurance.

  9. ATLAS Pixel IBL: Stave Quality Assurance

    CERN Document Server

    The ATLAS collaboration

    2014-01-01

    For Run 2 of the LHC a fourth innermost Pixel Detector layer on a smaller radius beam pipe has been installed in the ATLAS Detector to add redundancy against radiation damage of the current Pixel Detector and to ensure a high quality tracking and b-tagging performance of the Inner Detector over the coming years until the High Luminosity Upgrade. State of the art components have been produced and assembled onto support structures known as staves over the last two years. In total, 20 staves have been built and qualified in a designated Quality Assurance setup at CERN of which 14 have been integrated onto the beam pipe. Results from the testing are presented.

  10. CHALLENGES OF SOFTWARE QUALITY ASSURANCE AND TESTING

    Directory of Open Access Journals (Sweden)

    Md.Shahadat Hossain

    2018-02-01

    Full Text Available Uncertainty exists in Software Company over the world. Software quality problem is leading issue for the software industry. The issue exists from 40 years or 50 years long. The industry is suffering and closing for this issue. In this circumstance, it is important to address and remove its root cause. Otherwise, day by day industry economic loss will increase. I figure out some vital challenges of software quality assurance and testing which have been facing by software industries. The research focused on several small and medium software companies of the world. This paper represents different category of challenges along with responsible stakeholders. This research finds out that testing tools are available testing elements are available testing process has improved but still software has some testing challenges. My research figured out the bottleneck of challenges and explained in this paper. Here software engineers have scope to improve & overcome those challenges. This paper suggests systematic approach to solve the problem.

  11. Quality assurance in radiation therapy: clinical aspects

    International Nuclear Information System (INIS)

    Souhami, L.

    1984-01-01

    A survey was conducted in Latin America to evaluate the clinical aspects of quality assurance in radiotherapy. A questionnaire was prepared and sent to 46 institutions. Twenty-seven centers (58.5%), from nine countries, answered the questionnaire. The study was divided into three topics: a) patient-related statistics; b) staffing and education; and c) equipment and facilities. Radiotherapy training programs are available in only 37% of the centers studied. A large number of megavoltage units are old, operating at a shorter than optimum distance with sources of very low activity. The number of high energy linear accelerators is unsatisfactory. Problems in treatment planning facilities were also identified. Regionalization of radiation therapy services is recommended as a possible way to improve quality at a reasonable cost

  12. Effect of technology on quality assurance

    International Nuclear Information System (INIS)

    Purvis, E.E. III

    1984-01-01

    Optimizing Quality Assurance activities by taking advantage of technological improvements is an issue directly related to overall product cost, quality, and delivery schedules. Use of automated tooling and numerical control have reduced manufacturing cycle time and thereby enabled better response to changing consumer tastes and market demand. Non-nuclear industries are using computer-aided technology for in-process inspection and final product acceptance. Non-destructive examination can also be performed real-time, on the production line. The challenge faced by the nuclear industry is to make the best use of new and emerging technology while satisfying compliance requirements. Currently, use of new methods is hampered by uncertainty about the affect on regulatory issues. Ways of using the technology have been developed for commercial applications without consideration of nuclear requirements

  13. Quality Assurance for Essential Climate Variables

    Science.gov (United States)

    Folkert Boersma, K.; Muller, Jan-Peter

    2015-04-01

    Satellite data are of central interest to the QA4ECV project. Satellites have revolutionized the Earth's observation system of climate change and air quality over the past three decades, providing continuous data for the entire Earth. However, many users of these data are lost in the fog as to the quality of these satellite data. Because of this, the European Union expressed in its 2013 FP7 Space Research Call a need for reliable, traceable, and understandable quality information on satellite data records that could serve as a blueprint contribution to a future Copernicus Climate Change Service. The potential of satellite data to benefit climate change and air quality services is too great to be ignored. QA4ECV therefore bridges the gap between end-users of satellite data and the satellite data products. We are developing an internationally acceptable Quality Assurance (QA) framework that provides understandable and traceable quality information for satellite data used in climate and air quality services. Such a framework should deliver the historically linked long-term data sets that users need, in a format that they can readily use. QA4ECV has approached more than 150 users and suppliers of satellite data to collect their needs and expectations. The project will use their response as a guideline for developing user-friendly tools to obtain information on the completeness, accuracy, and fitness-for-purpose of the satellite datasets. QA4ECV collaborates with 4 joint FP7 Space projects in reaching out to scientists, policy makers, and other end-users of satellite data to improve understanding of the special challenges -and also opportunities- of working with satellite data for climate and air quality purposes. As a demonstration of its capacity, QA4ECV will generate multi-decadal climate data records for 3 atmospheric ECV precursors (nitrogen dioxide, formaldehyde, and carbon monoxide) and 3 land ECVs (albedo, leaf area index and absorbed photosynthetically active

  14. 222-S Laboratory Quality Assurance Plan. Revision 1

    International Nuclear Information System (INIS)

    Meznarich, H.K.

    1995-01-01

    This Quality Assurance Plan provides,quality assurance (QA) guidance, regulatory QA requirements (e.g., 10 CFR 830.120), and quality control (QC) specifications for analytical service. This document follows the U.S Department of Energy (DOE) issued Hanford Analytical Services Quality Assurance Plan (HASQAP). In addition, this document meets the objectives of the Quality Assurance Program provided in the WHC-CM-4-2, Section 2.1. Quality assurance elements required in the Guidelines and Specifications for Preparing Quality Assurance Program Plans (QAMS-004) and Interim Guidelines and Specifications for Preparing Quality Assurance Project Plans (QAMS-005) from the US Environmental Protection Agency (EPA) are covered throughout this document. A quality assurance index is provided in the Appendix A. This document also provides and/or identifies the procedural information that governs laboratory operations. The personnel of the 222-S Laboratory and the Standards Laboratory including managers, analysts, QA/QC staff, auditors, and support staff shall use this document as guidance and instructions for their operational and quality assurance activities. Other organizations that conduct activities described in this document for the 222-S Laboratory shall follow this QA/QC document

  15. Software quality assurance plan for PORFLOW-3D

    International Nuclear Information System (INIS)

    Maheras, S.J.

    1993-03-01

    This plan describes the steps taken by the Idaho National Engineering Laboratory Subsurface and Environmental Modeling Unit personnel to implement software quality assurance procedures for the PORFLOW-3D computer code. PORFLOW-3D was used to conduct radiological performance assessments at the Savannah River Site. software quality assurance procedures for PORFLOW-3D include software acquisition, installation, testing, operation, maintenance, and retirement. Configuration control and quality assurance procedures are also included or referenced in this plan

  16. Quality assurance during operation of nuclear power plants

    International Nuclear Information System (INIS)

    1994-01-01

    The general requirements applicable to the quality assurance of the Finnish nuclear power plants are presented in the Council of State Decision (395/91) and in the guide YVL 1.4. This guide specifies the quality assurance requirements to be applied during the operation of the nuclear power plants as well as of the other nuclear facilities. Quality assurance applies to all the activities and organizations with a bearing on the safe operation of the nuclear power plants. (5 refs.)

  17. Application of Quality Assurance to MCandA systems

    International Nuclear Information System (INIS)

    Skinner, A.J.; Delvin, W.L.

    1986-01-01

    Quality Assurance has been applied to the MCandA function within the Department of Energy's Savannah River Operations Office. It was applied to both the activities used to operate the MCandA Branch and the activities used by the Branch to overview the MCandA function of DOE/SR's contractor. In this paper, the principles of quality assurance are reviewed and their application at DOE/SR is discussed. In addition, quality assurance can be applied to the broader MCandA functions required of those facilities producing, using, and handling nuclear materials. Application of quality assurance to those broader functions is also discussed

  18. Quality Assurance Program Plan for FFTF effluent controls. Revision 1

    International Nuclear Information System (INIS)

    Seamans, J.A.

    1995-01-01

    This Quality Assurance Program Plan is specific to environmental related activities within the FFTF Property Protected Area. The activities include effluent monitoring and Low Level Waste Certification

  19. Army Programs: Army Finance and Accounting Quality Assurance Program

    National Research Council Canada - National Science Library

    1988-01-01

    This regulation discusses the primary responsibilities of commanders and staff officers at installation and higher levels for execution of the Army Finance and Accounting Quality Assurance (QA) Program...

  20. Quality assurance for health and environmental chemistry: 1989

    International Nuclear Information System (INIS)

    Gautier, M.A.; Gladney, E.S.; Koski, N.L.; Jones, E.A.; Phillips, M.B.; O'Malley, B.T.

    1990-12-01

    This report documents the continuing quality assurance efforts of the Health and Environmental Chemistry Group (HSE-9) at the Los Alamos National Laboratory. The philosophy, methodology, computing resources, and laboratory information management system used by the quality assurance program to encompass the diversity of analytical chemistry practiced in the group are described. Included in the report are all quality assurance reference materials used, along with their certified or consensus concentrations, and all analytical chemistry quality assurance measurements made by HSE-9 during 1989. 38 refs., 8 figs., 3 tabs

  1. Quality assurance program plan fuel supply shutdown project

    International Nuclear Information System (INIS)

    Metcalf, I.L.

    1998-01-01

    This Quality Assurance Program plan (QAPP) describes how the Fuel Supply Shutdown (FSS) project organization implements the quality assurance requirements of HNF-MP-599, Project Hanford Quality Assurance Program Description (QAPD) and the B and W Hanford Company Quality Assurance Program Plan (QAPP), FSP-MP-004. The QAPP applies to facility structures, systems, and components and to activities (e.g., design, procurement, testing, operations, maintenance, etc.) that could affect structures, systems, and components. This QAPP also provides a roadmap of applicable Project Hanford Policies and Procedures (PHPP) which may be utilized by the FSS project organization to implement the requirements of this QAPP

  2. Quality assurance in field radiation measurements

    International Nuclear Information System (INIS)

    Howell, W.P.

    1985-01-01

    In most cases, an ion chamber radiation measuring instrument is calibrated in a uniform gamma radiation field. This results in a uniform ionization field throughout the ion chamber. Measurement conditions encountered in the field often produce non-uniform ionization fields within the ion chamber, making determination of true dose rates to personnel difficult and prone to error. Extensive studies performed at Hanford have provided appropriate correction factors for use with one type of ion chamber instrument, the CP. Suitable corrections are available for the following distinct measurement circumstances: (1) contact measurements on large beta and gamma sources, (2) contact measurements on small beta and gamma sources, (3) contact measurements on small-diameter cylinders, (4) measurements in small gamma beams, and (5) measurements at a distance from large beta sources. Recommendations are made for the implementation of these correction factors, in the interest of improved quality assurance in field radiation measurements. 12 references, 10 figures

  3. Software quality assurance plan for viscometer

    International Nuclear Information System (INIS)

    Gimera, M.

    1994-01-01

    The in situ viscometer is a portable instrument designed to raise and lower a sphere (rheometer ball) through layers of tank waste material while recording ball position, velocity, and cable tension. In the field, the viscometer attaches to a decontamination spool piece which in turn is designed to attach to any 4-inch, 150-pound flange (typical of many available tank risers). The motion of the ball and collection of data is controlled by instrumentation and control equipment housed in a separate remote control console. This document covers the product, Viscometer Data Acquisition Software. This document provides the software quality assurance plan, verification and validation plan, and configuration management plan for developing the software for the instrumentation that will be used to obtain rheology data from Tank SY-101

  4. SAPHIRE 8 Volume 6 - Quality Assurance

    Energy Technology Data Exchange (ETDEWEB)

    C. L. Smith; R. Nims; K. J. Kvarfordt

    2011-03-01

    The Systems Analysis Programs for Hands-on Integrated Reliability Evaluations (SAPHIRE) Version 8 is a software application developed for performing a complete probabilistic risk assessment using a personal computer running the Microsoft Windows™ operating system. SAPHIRE 8 is funded by the U.S. Nuclear Regulatory Commission (NRC). The role of the INL in this project is that of software developer and tester. This development takes place using formal software development procedures and is subject to quality assurance (QA) processes. The purpose of this document is to describe how the SAPHIRE software QA is performed for Version 8, what constitutes its parts, and limitations of those processes. In addition, this document describes the Independent Verification and Validation that was conducted for Version 8 as part of an overall QA process.

  5. SAPHIRE 8 Software Quality Assurance Plan

    Energy Technology Data Exchange (ETDEWEB)

    Curtis Smith

    2010-02-01

    This Quality Assurance (QA) Plan documents the QA activities that will be managed by the INL related to JCN N6423. The NRC developed the SAPHIRE computer code for performing probabilistic risk assessments (PRAs) using a personal computer (PC) at the Idaho National Laboratory (INL) under Job Code Number (JCN) L1429. SAPHIRE started out as a feasibility study for a PRA code to be run on a desktop personal PC and evolved through several phases into a state-of-the-art PRA code. The developmental activity of SAPHIRE was the result of two concurrent important events: The tremendous expansion of PC software and hardware capability of the 90s and the onset of a risk-informed regulation era.

  6. Exploratory Shaft Facility quality assurance impact evaluation

    International Nuclear Information System (INIS)

    1987-08-01

    This report addresses the impact of the quality assurance practices used for the Exploratory Shaft Facility (ESF) design, and construction in licensing as part of the repository. Acceptance criteria used for evaluating the suitability of ESF QA practices are based on documents that had not been invoked for repository design or construction activities at the time of this evaluation. This report identifies the QA practices necessary for ESF design and construction licensability. A review and evaluation of QA practices for ESF design and construction resulted in the following conclusions. QA practices were found to be acceptable with a few exceptions. QA practices for construction activities were found to be insufficiently documented in implementing procedures to allow a full and effective evaluation for licensing purposes. Recommendations are provided for mitigating impacts to ensure compatibility of the QA practices with those considered necessary for repository licensing. 8 refs., 3 tabs

  7. Management services, quality assurance, and safety

    International Nuclear Information System (INIS)

    Anon.

    1987-01-01

    Broad technical and administrative support for the programmatic research and development activities of the Fusion Energy Division is provided by the Management Services Section and by the division's quality assurance (QA) and safety programs. Support is provided through effective communication with division programmatic staff and through the coordination of resources from disciplines outside the division. The QA activity in the division emphasizes the development and documentation of a QA program that conforms to national standards, the review and approval of engineering documents, supplier surveillance, identification and documentation of nonconforming items, audits, and QA assessments/plans. The division's safety activities include a formal safety program, emergency planning activities, and environmental protection services. Efforts devoted to the removal of hazardous wastes from division facilities were expanded during 1986

  8. Quality assurance auditing for nuclear power plants

    International Nuclear Information System (INIS)

    1980-01-01

    This Safety Guide provides requirements and recommendations for establishing and implementing a system of internal and external audits during the design, manufacture, construction, commissioning and operation of nuclear power plants. It provides for the planning, performance, reporting and follow-up of the quality assurance audit activity. It defines in general terms the responsibilities of the auditing and audited organizations. The Guide also covers auditing in the context of supplier evaluation; it does not include inspection for the sole purpose of process control or product acceptance. Like the Code, the present Guide was prepared as part of the IAEA's programme, referred to as the NUSS programme, for establishing Codes of Practice and Safety Guides relating to land-based stationary thermal neutron power plants

  9. Medical radio-physics. Quality assurance. Transparency

    International Nuclear Information System (INIS)

    Krembel, D.

    2009-07-01

    This short presentation, given by the national safety authority (ASN) at the meeting of July 1, 2009 of the high committee for the nuclear safety transparency and information (HCTISN), recalls, first, the missions of the ASN in the medical domain (radiation protection, control and inspections). Then it presents the reactions of the ASN in response to the increase of the number of radiological accidents since 2005: regulation reminder, circular letters, guidebooks, communication to the public and to the mass media. Finally, it defines the main priorities of the ASN with respect to radiotherapy: increase of human resources (radio-physicists shortage), declaration of incidents/accidents, quality assurance for the control of radiation doses delivered to patients, inspection of radiotherapy centres, expertise of new devices, improvement of softwares safety and ergonomics. (J.S.)

  10. Quality assurance for software important to safety

    International Nuclear Information System (INIS)

    2000-01-01

    Software applications play an increasingly relevant role in nuclear power plant systems. This is particularly true of software important to safety used in both: calculations for the design, testing and analysis of nuclear reactor systems (design, engineering and analysis software); and monitoring, control and safety functions as an integral part of the reactor systems (monitoring, control and safety system software). Computer technology is advancing at a fast pace, offering new possibilities in nuclear reactor design, construction, commissioning, operation, maintenance and decommissioning. These advances also present new issues which must be considered both by the utility and by the regulatory organization. Refurbishment of ageing instrumentation and control systems in nuclear power plants and new safety related application areas have emerged, with direct (e.g. interfaces with safety systems) and indirect (e.g. operator intervention) implications for safety. Currently, there exist several international standards and guides on quality assurance for software important to safety. However, none of the existing documents provides comprehensive guidance to the developer, manager and regulator during all phases of the software life-cycle. The present publication was developed taking into account the large amount of available documentation, the rapid development of software systems and the need for updated guidance on h ow to do it . It provides information and guidance for defining and implementing quality assurance programmes covering the entire life-cycle of software important to safety. Expected users are managers, performers and assessors from nuclear utilities, regulatory bodies, suppliers and technical support organizations involved with the development and use of software applied in nuclear power plants

  11. Accidents in radiotherapy: Lack of quality assurance?

    International Nuclear Information System (INIS)

    Novotny, J.

    1997-01-01

    About 150 radiological accidents, involving more than 3000 patients with adverse effects, 15 patient's fatalities and about 5000 staff and public exposures have been collected and analysed. Out of 67 analysed accidents in external beam therapy 22% has been caused by wrong calculation of the exposure time or monitor units, 13% by inadequate review of patient's chart, 12% by mistakes in the anatomical area to be treated. The remaining 35% can be attributed to 17 different causes. The most common mistakes in brachytherapy were wrong activities of sources used for treatment (20%), inadequate procedures for placement of sources applicators (14%), mistakes in calculating the treatment time (12%), etc. The direct and contributing causes of radiological accidents have been deduced from each event, when it was possible and categorized into 9 categories: mistakes in procedures (30%), professional mistakes (17%), communication mistakes (15%), lack of training (8.5%), interpretation mistakes (7%), lack of supervision (6%), mistakes in judgement (6%), hardware failures (5%), software and other mistakes (5.5%). Three types of direct and contributing causes responsible for almost 62% of all accidents are directly connected to the quality assurance of treatment. The lessons learnt from the accidents are related to frequencies of direct and contributing factors and show that most of the accident are caused by lack, non-application of quality assurance (QA) procedures or by underestimating of QA procedures. The international system for collection of accidents and dissemination of lessons learnt from the different accidents, proposed by IAEA, can contribute to better practice in many radiotherapy departments. Most of the accidents could have been avoided, had a comprehensive QA programme been established and properly applied in all radiotherapy departments, whatever the size. (author)

  12. Opinion of gastroenterologists towards quality assurance in endoscopy.

    Science.gov (United States)

    de Jonge, Vincent; Kuipers, Ernst J; van Leerdam, Monique E

    2011-03-01

    Quality assurance has become an important issue. Many societies are adopting quality assurance programs in order to monitor and improve quality of care. To assess the opinion of gastroenterologists towards quality assurance on the endoscopy department. A survey was sent to all gastroenterologists (n=319) in the Netherlands. It assessed their opinion on a quality assurance program for endoscopy units, including its design, logistics, and content. 200 gastroenterologists (63%) completed the questionnaire. 95% had a positive opinion towards quality assurance and 67% supposed an increase in quality. 28% assumed a negative impact on the time available for patient contact by introducing a quality assurance program and 35% that the capacity would decrease. A negative attitude towards disclosure of results to insurance companies (23%) and media (53%) was reported. Female gastroenterologists were less positive to share the results with other stakeholders (pquality measurements were assessment of complications (97%), standardised reporting (96%), and adequate patient information (95%). Gastroenterologists have a positive attitude towards quality assurance. However, concerns do exist about time investment and disclosure of results to others. Information provision and procedure characteristics were considered the most important aspects of quality assurance. Copyright © 2010 Editrice Gastroenterologica Italiana S.r.l. Published by Elsevier Ltd. All rights reserved.

  13. Software Quality Assurance for Nuclear Safety Systems

    International Nuclear Information System (INIS)

    Sparkman, D R; Lagdon, R

    2004-01-01

    The US Department of Energy has undertaken an initiative to improve the quality of software used to design and operate their nuclear facilities across the United States. One aspect of this initiative is to revise or create new directives and guides associated with quality practices for the safety software in its nuclear facilities. Safety software includes the safety structures, systems, and components software and firmware, support software and design and analysis software used to ensure the safety of the facility. DOE nuclear facilities are unique when compared to commercial nuclear or other industrial activities in terms of the types and quantities of hazards that must be controlled to protect workers, public and the environment. Because of these differences, DOE must develop an approach to software quality assurance that ensures appropriate risk mitigation by developing a framework of requirements that accomplishes the following goals: (sm b ullet) Ensures the software processes developed to address nuclear safety in design, operation, construction and maintenance of its facilities are safe (sm b ullet) Considers the larger system that uses the software and its impacts (sm b ullet) Ensures that the software failures do not create unsafe conditions Software designers for nuclear systems and processes must reduce risks in software applications by incorporating processes that recognize, detect, and mitigate software failure in safety related systems. It must also ensure that fail safe modes and component testing are incorporated into software design. For nuclear facilities, the consideration of risk is not necessarily sufficient to ensure safety. Systematic evaluation, independent verification and system safety analysis must be considered for software design, implementation, and operation. The software industry primarily uses risk analysis to determine the appropriate level of rigor applied to software practices. This risk-based approach distinguishes safety

  14. A framework for institutionalizing quality assurance.

    Science.gov (United States)

    Silimperi, Diana R; Franco, Lynne Miller; Veldhuyzen van Zanten, Tisna; MacAulay, Catherine

    2002-12-01

    To develop a framework to support the institutionalization of quality assurance (QA). The framework for institutionalizing QA consists of a model of eight essential elements and a 'roadmap' for the process of institutionalization. The essential elements are the building blocks required for implementing and sustaining QA activities. Core QA activities include defining, measuring and improving quality. The essential elements are grouped under three categories: the internal enabling environment (internal to the organization or system), organizing for quality, and support functions. The enabling environment contains the essential elements of leadership, policy, core values, and resources. Organizing for quality includes the structure for implementing QA. Three essential elements are primarily support functions: capacity building, communication and information, and rewarding quality. The model can be applied at the level of an organization or a system. The paper also describes the process of institutionalizing QA, starting from a state of preawareness, passing through four phases (awareness, experiential, expansion, and consolidation), and culminating in a state of maturity. The process is not linear; an organization may regress, vacillate between phases, or even remain stagnant. Some phases (e.g. awareness and experiential) may occur simultaneously. The framework has been introduced in nearly a dozen countries in Latin America and Africa. The conceptual model has been used to support strategic planning and directing Ministry of Health work plans, and also as a resource for determining the elements necessary to strengthen and sustain QA. The next step will be the development and evaluation of an assessment tool to monitor developmental progress in the institutionalization of QA.

  15. Develpment of quality assurance manual for fabrication of DUPIC fuel

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Young Gun; Lee, J. W.; Kim, S. S. and others

    2001-09-01

    The Quality Assurance Manual for the fabrication of DUPIC fuel with high quality was developed. The Quality Assurance Policy established by this manual is to assure that the DUPIC fuel element supplied to customer conform to the specified requirements of customer, applicable codes and standards. The management of KAERI is committed to implementation and maintenance of the program described by this manual. This manual describes the quality assurance program for DUPIC fuel fabrication to comply with CAN3-Z299.2-85 to the extent as needed and appropriate. This manual describes the methods which DUPIC Fuel Development Team(DFDT) personnel must follow to achieve and assure high quality of our product. This manual also describes the quality management system applicable to the activities performed at DFDT.

  16. Develpment of quality assurance manual for fabrication of DUPIC fuel

    International Nuclear Information System (INIS)

    Lee, Young Gun; Lee, J. W.; Kim, S. S. and others

    2001-09-01

    The Quality Assurance Manual for the fabrication of DUPIC fuel with high quality was developed. The Quality Assurance Policy established by this manual is to assure that the DUPIC fuel element supplied to customer conform to the specified requirements of customer, applicable codes and standards. The management of KAERI is committed to implementation and maintenance of the program described by this manual. This manual describes the quality assurance program for DUPIC fuel fabrication to comply with CAN3-Z299.2-85 to the extent as needed and appropriate. This manual describes the methods which DUPIC Fuel Development Team(DFDT) personnel must follow to achieve and assure high quality of our product. This manual also describes the quality management system applicable to the activities performed at DFDT

  17. Quality assurance programme in diagnostic radiology

    International Nuclear Information System (INIS)

    Yacovenco, A.A.

    1996-01-01

    One hundred years after the discovery of X-rays, they continue being nowadays part of physicians' daily activities, and the diagnosis through the use of X-ray equipment is one of the most important fields in clinical medicine, thus becoming the most important cause of human exposure to artificial sources. For this reason, in the last twenty years, most of the developed countries did the utmost to establish programs which could warrant the quality of the radiographic image. Aiming the protection of human being against the harmful effects of ionizing radiations, in December 1980, World Health Organization decided to form a group of professionals highly experienced in medical radiology, and initiate an inspection and quality control program. In September 1988, the Group of Studies of the Program Related to Radiological Protection of the Commission in the European Communities, prepared a working paper in which guidelines were set up regarding quality of images, dosage to patient, and associated radiographic factors, necessary to obtain acceptable radiologic performance. In Brazil, efforts driven in this direction, guided by some equipment testing, starting in 1990, began to be more known. When the Director and the Head of Radiology in the Military Police Hospital of the State of Rio de Janeiro (HPM) reamed about these efforts, they decided to contact the Institute for Radioprotection and Dosimetry (IRD) of Comissao Nacional de Energia Nuclear and submit the problem of low radiologic performance and increasing rates of rejection. Thus, with the coincidence of interests and needs, along with a proposal from the Commission of the European Communities (CEC), IRD decided to offer the author laboratory support to elaborate a Quality Assurance Program (QAP) to be implemented in HPM. (author)

  18. Quality assurance of the bentonite material

    International Nuclear Information System (INIS)

    Ahonen, L.; Korkeakoski, P.; Tiljander, M.; Kivikoski, H.; Laaksonen, R.

    2008-05-01

    This report describes a quality assurance chain for the bentonite material acquisition for a nuclear waste disposal repository. Chemical, mineralogical and geotechnical methods, which may be applied in quality control of bentonite are shortly reviewed. As a case study, many of the presented control studies were performed for six different bentonite samples. Chemical analysis is a very reliable research method to control material homogeneity, because the accuracy and repeatability of the study method is extremely good. Accurate mineralogical study of bentonite is a complicated task. X-ray diffractometry is the best method to identify smectite minerals, but quantitative analysis of smectite content remains uncertain. To obtain a better quantitative analysis, development of techniques based on automatic image analysis of SEM images is proposed. General characteristics of bentonite can be obtained by rapid indicator tests, which can be done on the place of reception. These tests are methylene blue test giving information on the cation exchange capacity, swelling index and determination of water absorption. Different methods were used in the determination of cation exchange capacity (CEC) of bentonite. The results indicated differences both between methodologies and between replicate determinations for the same material and method. Additional work should be done to improve the reliability and reproducibility of the methodology. Bentonite contains water in different modes. Thus, different determination methods are used in bentonite studies and they give somewhat dissimilar results. Clay research use frequently the so-called consistency tests (liquid limit, plastic limit and plasticity index). This study method does, however, not seem to be very practical in quality control of bentonite. Therefore, only the determination of liquid limit with fall-cone method is recommended for quality control. (orig.)

  19. Quality assurance in fractionated stereotactic radiotherapy

    International Nuclear Information System (INIS)

    Warrington, A.P.; Laing, R.W.; Brada, M.

    1994-01-01

    The recent development of fractionated stereotactic radiotherapy (SRT), which utilises the relocatable Gill-Thomas-Cosman frame (GTC 'repeat localiser'), requires comprehensive quality assurance (QA). This paper focuses on those QA procedures particularly relevant to fractionated SRT treatments, and which have been derived from the technique used at the Royal Marsden Hospital. They primarily relate to the following: (i) GTC frame fitting, initially in the mould room, and then at each imaging session and treatment fraction; (ii) checking of the linear accelerator beam geometry and alignment lasers; and (iii) setting up of the patient for each fraction of treatment. The precision of the fractionated technique therefore depends on monitoring the GTC frame relocation at each fitting, checking the accuracy of the radiation isocentre of the treatment unit, its coincidence with the patient alignment lasers and the adjustments required to set the patient up accurately. The results of our quality control checks show that setting up to a mean radiation isocentre using precisely set-up alignment lasers can be achievable to within 1 mm accuracy. When this is combined with a mean GTC frame relocatability of 1 mm on the patient, a 2-mm allowance between the prescribed isodose surface and the defined target volume is a realistic safety margin for this technique

  20. Quality assurance in surgical practice through auditing.

    Science.gov (United States)

    Wong, W T

    1980-05-01

    An efficient auditing method is presented which involves objective criteria-based numerical screening of medical process and treatment outcome by paramedical staff and detailed analysis of deviated cases by surgeons. If properly performed it requires the study of no more than 50 cases in a diagnostic category to provide sufficient information about the quality of care. Encouraging points as well as problems are communicated to the surgeons to induce the maintenance or improvement of the standard of care. Graphic documentation of case performance is possible, allowing surgeons to compare results with their colleagues. The general performance level of several consecutive studies can be compared at a glance. In addition, logical education programs to improve the medical process can be designed on the basis of the problems identified. As all the cases with an unacceptable outcome are traceable to inadequate medical process, improvement in this area will decrease outcome defects. With the use of auditing and the follow-up technique described, the quality of care in surgery may be assured.

  1. Quality assurance program description for shipping packages of radioactive material

    International Nuclear Information System (INIS)

    1978-01-01

    This quality assurance plan describes the quality assurance program at the Pacific Northwest Laboratory (PNL), for shipping packages of radioactive material. The purpose of this report is to describe how PNL will comply with the Code of Federal Regulations, Title 10, Part 71, Appendix E. In compliance with the instructions from the Nuclear Regulatory Commission (NRC), the 18 criteria from Appendix E are covered

  2. Quality assurance in a large research and development laboratory

    International Nuclear Information System (INIS)

    Neill, F.H.

    1980-01-01

    Developing a quality assurance program for a large research and development laboratory provided a unique opportunity for innovative planning. The quality assurance program that emerged has been tailored to meet the requirements of several sponsoring organizations and contains the flexibility for experimental programs ranging from large engineering-scale development projects to bench-scale basic research programs

  3. Quality assurance during preoperational testing and during startup operation

    International Nuclear Information System (INIS)

    Eisele, H.; Meyer, F.A.

    1980-01-01

    Rules and guidelines for the quality assurance. Quality assurance in the course of preoperational testing and the startup period: preoperational testing; hot functional test I; hot functional test II; initial making critical and zero power physics testing; power range testing. Startup documents: startup program; startup instructions; startup data sheet; startup sequence outlines; final startup reports. Advisory safety committee for nuclear startup. (orig./RW)

  4. Quality assurance programme for the LVR-15 nuclear research reactor

    International Nuclear Information System (INIS)

    1995-03-01

    The document specifies all aspects of the quality assurance programme for the LVR-15 nuclear research reactor. The programme addresses the organization and responsibilities, basic quality assurance activities, and identification of management, planning, and working documents necessary to implement the programme. (P.A.)

  5. A Rotational Blended Learning Model: Enhancement and Quality Assurance

    Science.gov (United States)

    Ghoul, Said

    2013-01-01

    Research on blended learning theory and practice is growing nowadays with a focus on the development, evaluation, and quality assurance of case studies. However, the enhancement of blended learning existing models, the specification of their online parts, and the quality assurance related specifically to them have not received enough attention.…

  6. Quality assurance and evidence in career guidance in Europe

    DEFF Research Database (Denmark)

    Plant, Peter

    2011-01-01

    Quality assurance and evidence in career guidance in Europe is based on a particular, positivtic model. Other approaches are largely neglected.......Quality assurance and evidence in career guidance in Europe is based on a particular, positivtic model. Other approaches are largely neglected....

  7. Internal Quality Assurance Benchmarking. ENQA Workshop Report 20

    Science.gov (United States)

    Blackstock, Douglas; Burquel, Nadine; Comet, Nuria; Kajaste, Matti; dos Santos, Sergio Machado; Marcos, Sandra; Moser, Marion; Ponds, Henri; Scheuthle, Harald; Sixto, Luis Carlos Velon

    2012-01-01

    The Internal Quality Assurance group of ENQA (IQA Group) has been organising a yearly seminar for its members since 2007. The main objective is to share experiences concerning the internal quality assurance of work processes in the participating agencies. The overarching theme of the 2011 seminar was how to use benchmarking as a tool for…

  8. Quality Assurance Program Plan for radionuclide airborne emissions monitoring

    International Nuclear Information System (INIS)

    Vance, L.M.

    1993-07-01

    This Quality Assurance Program Plan (QAPP) describes the quality assurance requirements and responsibilities for radioactive airborne emissions measurements activities from regulated stacks are controlled at the Hanford Site. Detailed monitoring requirements apply to stacks exceeding 1% of the standard of 10 mrem annual effective dose equivalent to the maximally exposed individual from operations of the Hanford Site

  9. Illinois' Forests, 2005: Statistics, Methods, and Quality Assurance

    Science.gov (United States)

    Susan J. Crocker; Charles J. Barnett; Mark A. Hatfield

    2013-01-01

    The first full annual inventory of Illinois' forests was completed in 2005. This report contains 1) descriptive information on methods, statistics, and quality assurance of data collection, 2) a glossary of terms, 3) tables that summarize quality assurance, and 4) a core set of tabular estimates for a variety of forest resources. A detailed analysis of inventory...

  10. Quality Assurance of Joint Programmes. ENQA Workshop Report 19

    Science.gov (United States)

    Frederiks, Mark; Grifoll, Josep; Hiltunen, Kirsi; Hopbach, Achim

    2012-01-01

    In view of the Bologna ministerial conference to be held in April 2012 in Bucharest, ENQA organised a seminar in September 2011 on Quality Assurance of Joint Programmes in collaboration with the Austrian Accreditation Council (OAR). The purpose of this seminar was twofold: first, to analyse the experience already gained in quality assurance of…

  11. Quality assurance program plan for radionuclide airborne emissions monitoring

    International Nuclear Information System (INIS)

    Boom, R.J.

    1995-03-01

    This Quality Assurance Program Plan identifies quality assurance program requirements and addresses the various Westinghouse Hanford Company organizations and their particular responsibilities in regards to sample and data handling of airborne emissions. The Hanford Site radioactive airborne emissions requirements are defined in National Emissions Standards for Hazardous Air Pollutants (NESHAP), Code of Federal Regulations, Title 40, Part 61, Subpart H (EPA 1991a). Reporting of the emissions to the US Department of Energy is performed in compliance with requirements of US Department of Energy, Richland Operations Office Order 5400.1, General Environmental Protection Program (DOE-RL 1988). This Quality Assurance Program Plan is prepared in accordance with and to the requirements of QAMS-004/80, Guidelines and Specifications for Preparing Quality Assurance Program Plans (EPA 1983). Title 40 CFR Part 61, Appendix B, Method 114, Quality Assurance Methods (EPA 1991b) specifies the quality assurance requirements and that a program plan should be prepared to meet the requirements of this regulation. This Quality Assurance Program Plan identifies NESHAP responsibilities and how the Westinghouse Hanford Company Environmental, Safety, Health, and Quality Assurance Division will verify that the methods are properly implemented

  12. Quality Assurance for Distance Education: A Faculty Peer Review Process.

    Science.gov (United States)

    Ross, Kathryn R.; Batzer, Lyn; Bennington, Elaine

    2002-01-01

    Discusses the need for quality assurance in distance education; describes evaluation criteria; and reports how Ivy Tech State College (Indiana) created a peer review process as a formative evaluation tool to assure the quality of its distance education courses. Explains roles of the participants and evaluation of the peer review prototype. (LRW)

  13. Regulating and Quality-Assuring VET: International Developments. Research Report

    Science.gov (United States)

    Misko, Josie

    2015-01-01

    The opening-up of the market for education and training, including vocational education and training (VET), has increased the importance of regulation and quality assurance mechanisms in ensuring the integrity of qualifications. This report investigates approaches to the regulation and quality assurance of vocational education and training in a…

  14. 40 CFR Appendix C to Part 61 - Quality Assurance Procedures

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 8 2010-07-01 2010-07-01 false Quality Assurance Procedures C Appendix...—Quality Assurance Procedures Procedure 1—Determination of Adequate Chromatographic Peak Resolution In this....” Procedure 2—Procedure for Field Auditing GC Analysis Responsibilities of audit supervisor and analyst at the...

  15. Current Trends in European Quality Assurance. ENQA Workshop Report 8

    Science.gov (United States)

    Bozo, Dhurata; Damian, Radu; Gonzalez, Cecilia de la Rosa; Helle, Emmi; Imoda, Franco; Kohler, Alexander; Papazoglou, Vassilios J.; Dalmau, Gemma Rauret; Shopov, Todor

    2009-01-01

    The present report is a product of two ENQA (European Association for Quality Assurance in Higher Education) seminars, held in 2007, on current trends in European Quality Assurance. The first seminar, hosted by the Bulgarian National Evaluation and Accreditation Agency (NEAA), examined the situation in South-Eastern Europe. The second seminar…

  16. Quality assurance standards of nuclear equipment and international cooperation

    International Nuclear Information System (INIS)

    Savanger, J.M.

    1983-01-01

    This paper analyses the quality assurance system; it briefly defines the meaning of this concept and assesses the status of quality assurance in France. The author also reviews the problems and difficulties encountered in the setting up of this system. (NEA) [fr

  17. 21 CFR 892.1940 - Radiologic quality assurance instrument.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Radiologic quality assurance instrument. 892.1940 Section 892.1940 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES RADIOLOGY DEVICES Diagnostic Devices § 892.1940 Radiologic quality assurance...

  18. Interdisciplinary group of mammography (IGM). Quality assurance in mammography

    International Nuclear Information System (INIS)

    Anon.

    1994-01-01

    Assurance quality must be a preoccupation of each day in mammography. To be efficient and of low cost it must be discussed between radiologists and physicists; some countries like Federal Republic of Germany, Belgium, United Kingdom, Scandinavia and Netherlands engaged actions to make assurance quality a daily practice

  19. Quality assurance in siting of Nuclear Power Plants

    International Nuclear Information System (INIS)

    2005-03-01

    This guide describes the requirements of quality assurance programme (QAP) that need to be implemented at the siting stage, by the organisation having overall responsibility for the nuclear power plant. The scope of the guide covers the quality assurance aspects related to management, performance and assessment activities during siting stage of NPPs

  20. 7 CFR 90.102 - Quality assurance review.

    Science.gov (United States)

    2010-01-01

    ... procedures; (3) A review of records for the calibration and maintenance of equipment; (4) A review of records..., Inspections, Marketing Practices), DEPARTMENT OF AGRICULTURE (CONTINUED) COMMODITY LABORATORY TESTING PROGRAMS INTRODUCTION Quality Assurance § 90.102 Quality assurance review. (a) Each laboratory performing tests and...

  1. Quality Assurance Program Plan for radionuclide airborne emissions monitoring

    Energy Technology Data Exchange (ETDEWEB)

    Vance, L.M.

    1993-07-01

    This Quality Assurance Program Plan (QAPP) describes the quality assurance requirements and responsibilities for radioactive airborne emissions measurements activities from regulated stacks are controlled at the Hanford Site. Detailed monitoring requirements apply to stacks exceeding 1% of the standard of 10 mrem annual effective dose equivalent to the maximally exposed individual from operations of the Hanford Site.

  2. Quality Control and Quality Assurance of Radiation Oncology

    International Nuclear Information System (INIS)

    Abaza, A.

    2016-01-01

    Radiotherapy (RT) has played important roles in cancer treatment for more than one century. The development of RT techniques allows high-dose irradiation to tumors while reducing the radiation doses delivered to surrounding normal tissues. However, RT is a complex process and involves understanding of the principles of medical physics, radiobiology, radiation safety, dosimetry, radiation treatment planning, simulation and interaction of radiation with other treatment modalities. Each step in the integrated process of RT needs quality control and quality assurance (QA) to prevent errors and to ensure that patients will receive the prescribed treatment correctly. The aim of this study is to help the radio therapists in identifying a system for QA that balances patient safety and quality with available resources. Recent advances in RT focus on the need for a systematic RT QA program that balances patient safety and quality with available resources. It is necessary to develop more formal error mitigation and process analysis methods, such as failure mode and effect analysis (FMEA), to focus available QA resources optimally on the process components. External audit programs are also effective. Additionally, Clinical trial QA has a significant role in enhancing the quality of care. The International Atomic Energy Agency (IAEA) has operated both an on-site and off-site postal dosimetry audit to improve practice and to assure the dose from RT equipment. Both postal dosimetry audit and clinical trial RTQA, especially for advanced technologies, in collaboration with global networks, will serve to enhance patient safety and quality of care

  3. [Quality measurement using administrative data in mandatory quality assurance].

    Science.gov (United States)

    Heller, Günther; Szecsenyi, Joachim; Willms, Gerald; Broge, Björn

    2014-01-01

    For several years, the use of administrative data in mandatory quality measurement has been requested by several stakeholders in Germany. Main advantages of using administrative data include the reduction of documentary expenditures and the possibility to perform longitudinal quality analyses across different healthcare units. After a short introduction, a brief overview of the current use of administrative data for mandatory quality assurance as well as current developments is given, which will then be further exemplified by decubital ulcer prophylaxis. By using administrative data coding expenditures in this clinical area could be reduced by nine million data fields. At the same time the population analysed was expanded resulting in a more than tenfold increase in potentially quality-relevant events. Finally, perspectives, further developments, possibilities as well as limits of quality measurement with administrative data are discussed. Copyright © 2014. Published by Elsevier GmbH.

  4. Quality Assurance Program Plan (QAPP) Waste Management Project

    Energy Technology Data Exchange (ETDEWEB)

    VOLKMAN, D.D.

    1999-10-27

    This document is the Quality Assurance Program Plan (QAPP) for Waste Management Federal Services of Hanford, Inc. (WMH), that implements the requirements of the Project Hanford Management Contract (PHMC), HNF-MP-599, Project Hanford Quality Assurance Program Description (QAPD) document, and the Hanford Federal Facility Agreement with Consent Order (Tri-Party Agreement), Sections 6.5 and 7.8. WHM is responsible for the treatment, storage, and disposal of liquid and solid wastes generated at the Hanford Site as well as those wastes received from other US Department of Energy (DOE) and non-DOE sites. WMH operations include the Low-Level Burial Grounds, Central Waste Complex (a mixed-waste storage complex), a nonradioactive dangerous waste storage facility, the Transuranic Storage Facility, T Plant, Waste Receiving and Processing Facility, 200 Area Liquid Effluent Facility, 200 Area Treated Effluent Disposal Facility, the Liquid Effluent Retention Facility, the 242-A Evaporator, 300 Area Treatment Effluent Disposal Facility, the 340 Facility (a radioactive liquid waste handling facility), 222-S Laboratory, the Waste Sampling and Characterization Facility, and the Hanford TRU Waste Program.

  5. Research and development quality assurance planning

    Energy Technology Data Exchange (ETDEWEB)

    Hoke, P.B.

    1990-05-14

    Planning for quality assurance (QA) in research and development (R D) is like stealing eggs without waking up the chickens. The QA program should be as unobtrusive as possible. Researchers require a QA program that affords them an environment capable of supporting repeatable experiments with accurate data without unduly stifling their creative abilities. Careful advance planning ensures that the intensity of control provided by quality-related systems is commensurate with the importance and scope of the activities being performed. Good scientific practices applied to small bench-scale projects may require minimal additional controls. As projects increase in size and complexity the controls imposed through planning must, by necessity, be increased. Research and development QA planning, just like any other planning, involves all affected individuals. The application of control systems is determined by factors such as customer or sponsor requirements, the importance of an item or activity to the experiment's success, and the organizational complexity of the project. Many larger experiments are highly dependent on quality-related support activities such as calibration, engineering design, and inspection provided by organizations outside the R D group. Since, in most cases, the expense of support activities is taken directly from funds available for research, it is important for the researchers to be involved in the planning efforts to help determine and agree with the level of QA effort required. A single plan will often suffice for organizations engaged in large numbers of similar experiments. Complex experiments may require unique QA plans or additions to existing plans. Once implemented, the R D QA plans, like any others, require audits or surveillances and may require revisions if the scope of the experiment changes. 1 ref., 1 fig.

  6. Research and development quality assurance planning

    International Nuclear Information System (INIS)

    Hoke, P.B.

    1990-01-01

    Planning for quality assurance (QA) in research and development (R ampersand D) is like stealing eggs without waking up the chickens. The QA program should be as unobtrusive as possible. Researchers require a QA program that affords them an environment capable of supporting repeatable experiments with accurate data without unduly stifling their creative abilities. Careful advance planning ensures that the intensity of control provided by quality-related systems is commensurate with the importance and scope of the activities being performed. Good scientific practices applied to small bench-scale projects may require minimal additional controls. As projects increase in size and complexity the controls imposed through planning must, by necessity, be increased. Research and development QA planning, just like any other planning, involves all affected individuals. The application of control systems is determined by factors such as customer or sponsor requirements, the importance of an item or activity to the experiment's success, and the organizational complexity of the project. Many larger experiments are highly dependent on quality-related support activities such as calibration, engineering design, and inspection provided by organizations outside the R ampersand D group. Since, in most cases, the expense of support activities is taken directly from funds available for research, it is important for the researchers to be involved in the planning efforts to help determine and agree with the level of QA effort required. A single plan will often suffice for organizations engaged in large numbers of similar experiments. Complex experiments may require unique QA plans or additions to existing plans. Once implemented, the R ampersand D QA plans, like any others, require audits or surveillances and may require revisions if the scope of the experiment changes. 1 ref., 1 fig

  7. Quality assurance in the creative enterprise: an appraisal of select ...

    African Journals Online (AJOL)

    Thus, the aim of this study is how to assure quality in the creative process ... study and content analysis research approaches of the qualitative research method. The researchers concluded that adherence to theory can build and sustain quality ...

  8. Quality assurance during the manufacture of nuclear power plant components

    International Nuclear Information System (INIS)

    Mueller, J.

    1976-01-01

    Apart from the special requirements of quality assurance in the production of components for the nuclear industry, in particular nuclear power stations, the author discusses special methods of quality control in the testing of welded joints. (TK) [de

  9. Quality assurance in non-interventional studies

    Directory of Open Access Journals (Sweden)

    Capan, Müge

    2009-11-01

    Full Text Available Nowadays, drug research and surveillance after authorisation becomes more and more important for several reasons. Non-interventional studies (NIS investigate various aspects of drug use including efficacy and safety under real life conditions. Such kind of health services research should be on a high scientific, methodological and organisational level. Therefore accompanying measures to improve or to keep the quality are highly recommended. The aim of quality management is: first to avoid bias of results by using an appropriate study design and an adequate data analysis, second to assure authenticity, completeness and validity of the data and third to identify and resolve deficiencies at an early stage. Basic principles are laid down in corresponding guidelines and recommendations of authorities, institutes and societies. Various guidelines for good epidemiological practice (GEP were published by the U.S. Food and Drug Administration (FDA and international and regional societies for epidemiology. In addition in Germany the Federal Institute for Drugs and Medical Devices (BfArM together with the Paul Ehrlich Institute (PEI and the German Association of Research-Based Pharmaceutical Companies (VFA have published respectively recommendations dealing with quality aspects of non-interventional observational studies. Key points are the advanced publishing of information about the project, developing of a study plan/protocol containing the scientific objectives, a sample size justification and a description of the planned analyses and the publishing of a summary of the results timely after completion of the study. The quality of the data can be improved by using standardized case report forms (CRF and the CRF should be reviewed and tested before start of study by some participants. A source data verification (SDV should be performed in randomly selected centres – in between 2% and 5% of the centres depending on the number of participating centres

  10. Quality assurance in non-interventional studies.

    Science.gov (United States)

    Theobald, Karlheinz; Capan, Müge; Herbold, Marlis; Schinzel, Stefan; Hundt, Ferdinand

    2009-11-09

    Nowadays, drug research and surveillance after authorisation becomes more and more important for several reasons. Non-interventional studies (NIS) investigate various aspects of drug use including efficacy and safety under real life conditions. Such kind of health services research should be on a high scientific, methodological and organisational level. Therefore accompanying measures to improve or to keep the quality are highly recommended. The aim of quality management is: first to avoid bias of results by using an appropriate study design and an adequate data analysis, second to assure authenticity, completeness and validity of the data and third to identify and resolve deficiencies at an early stage. Basic principles are laid down in corresponding guidelines and recommendations of authorities, institutes and societies. Various guidelines for good epidemiological practice (GEP) were published by the U.S. Food and Drug Administration (FDA) and international and regional societies for epidemiology. In addition in Germany the Federal Institute for Drugs and Medical Devices (BfArM) together with the Paul Ehrlich Institute (PEI) and the German Association of Research-Based Pharmaceutical Companies (VFA) have published respectively recommendations dealing with quality aspects of non-interventional observational studies. Key points are the advanced publishing of information about the project, developing of a study plan/protocol containing the scientific objectives, a sample size justification and a description of the planned analyses and the publishing of a summary of the results timely after completion of the study. The quality of the data can be improved by using standardized case report forms (CRF) and the CRF should be reviewed and tested before start of study by some participants. A source data verification (SDV) should be performed in randomly selected centres - in between 2% and 5% of the centres depending on the number of participating centres. Before start of

  11. Internal Quality Assurance--Enhancing Quality Culture. ENQA Workshop Report 16

    Science.gov (United States)

    ENQA (European Association for Quality Assurance in Higher Education), 2010

    2010-01-01

    The European Association for Quality Assurance in Higher Education (ENQA), in cooperation with the Quality Assurance Agency (QAA, UK), organised a seminar on theme "Internal Quality Assurance--Enhancing quality culture" which was held on 8-9 June, 2010 in London, United Kingdom. The seminar marked the fourth annual meeting of the ENQA…

  12. 40 CFR 75.21 - Quality assurance and quality control requirements.

    Science.gov (United States)

    2010-07-01

    ... quality assurance audit or any other audit, the system is out-of-control. The owner or operator shall... 40 Protection of Environment 16 2010-07-01 2010-07-01 false Quality assurance and quality control... assurance and quality control requirements. (a) Continuous emission monitoring systems. The owner or...

  13. Tool Use Within NASA Software Quality Assurance

    Science.gov (United States)

    Shigeta, Denise; Port, Dan; Nikora, Allen P.; Wilf, Joel

    2013-01-01

    As space mission software systems become larger and more complex, it is increasingly important for the software assurance effort to have the ability to effectively assess both the artifacts produced during software system development and the development process itself. Conceptually, assurance is a straightforward idea - it is the result of activities carried out by an organization independent of the software developers to better inform project management of potential technical and programmatic risks, and thus increase management's confidence in the decisions they ultimately make. In practice, effective assurance for large, complex systems often entails assessing large, complex software artifacts (e.g., requirements specifications, architectural descriptions) as well as substantial amounts of unstructured information (e.g., anomaly reports resulting from testing activities during development). In such an environment, assurance engineers can benefit greatly from appropriate tool support. In order to do so, an assurance organization will need accurate and timely information on the tool support available for various types of assurance activities. In this paper, we investigate the current use of tool support for assurance organizations within NASA, and describe on-going work at JPL for providing assurance organizations with the information about tools they need to use them effectively.

  14. Quality Assurance Standards for Symptomatic Breast Disease Services

    OpenAIRE

    Department of Health (Ireland)

    2007-01-01

    Quality Assurance Standards for Symptomatic Breast Disease Services People in Ireland have a right to expect that medical care be of good quality. They expect that standards of care are consistently high. They expect that access to care is easy, speedy, effective and efficient. Society expects quality of care to measure up to international norms of good practice. Such assurance can be given by auditing the quality of activity. Click here to download PDF 606kb

  15. Quality Assurance in the European Higher Education Area: The Emergence of a German Market for Quality Assurance Agencies

    Science.gov (United States)

    Serrano-Velarde, Kathia E.

    2008-01-01

    Most European countries have introduced systematic quality assurance as part of an overall governance reform aimed at enhancing universities' autonomy. Researchers and economic entrepreneurs tend, however, to underestimate the political dimension of accreditation and evaluation when they consider the contribution of quality assurance to the…

  16. Quality Assurance Framework for Mini-Grids

    Energy Technology Data Exchange (ETDEWEB)

    Baring-Gould, Ian [National Renewable Energy Lab. (NREL), Golden, CO (United States); Burman, Kari [National Renewable Energy Lab. (NREL), Golden, CO (United States); Singh, Mohit [National Renewable Energy Lab. (NREL), Golden, CO (United States); Esterly, Sean [National Renewable Energy Lab. (NREL), Golden, CO (United States); Mutiso, Rose [US Department of Energy, Washington, DC (United States); McGregor, Caroline [US Department of Energy, Washington, DC (United States)

    2016-11-01

    Providing clean and affordable energy services to the more than 1 billion people globally who lack access to electricity is a critical driver for poverty reduction, economic development, improved health, and social outcomes. More than 84% of populations without electricity are located in rural areas where traditional grid extension may not be cost-effective; therefore, distributed energy solutions such as mini-grids are critical. To address some of the root challenges of providing safe, quality, and financially viable mini-grid power systems to remote customers, the U.S. Department of Energy (DOE) teamed with the National Renewable Energy Laboratory (NREL) to develop a Quality Assurance Framework (QAF) for isolated mini-grids. The QAF for mini-grids aims to address some root challenges of providing safe, quality, and affordable power to remote customers via financially viable mini-grids through two key components: (1) Levels of service: Defines a standard set of tiers of end-user service and links them to technical parameters of power quality, power availability, and power reliability. These levels of service span the entire energy ladder, from basic energy service to high-quality, high-reliability, and high-availability service (often considered 'grid parity'); (2) Accountability and performance reporting framework: Provides a clear process of validating power delivery by providing trusted information to customers, funders, and/or regulators. The performance reporting protocol can also serve as a robust monitoring and evaluation tool for mini-grid operators and funding organizations. The QAF will provide a flexible alternative to rigid top-down standards for mini-grids in energy access contexts, outlining tiers of end-user service and linking them to relevant technical parameters. In addition, data generated through implementation of the QAF will provide the foundation for comparisons across projects, assessment of impacts, and greater confidence that

  17. Quality Assurance in Trichiasis Surgery: a methodology

    Science.gov (United States)

    Buchan, John C; Limburg, Hans; Burton, Matthew J

    2013-01-01

    SUMMARY Trachoma remains a significant cause of blindness in many parts of the world. The major route to blindness involves upper lid entropion leading to trachomatous trichiasis (TT) which promotes progressive corneal opacification. The provision of surgery to correct TT in the populations most severely affected is a major challenge for the global effort to eliminate Trachoma blindness by the year 2020. Most attention has been paid to increasing the quantity of TT surgery performed, and large numbers of non-doctor operators have been trained to this end. Surgical audit by those performing TT surgery is not a routine part of any national trachoma control programme, and no effective mechanism exists for identifying surgeons experiencing poor outcomes. We propose a methodology for surgical audit at the level of the individual surgeon based on Lot Quality Assurance. A set number of patients operated on previously for upper eyelid TT are examined to detect the recurrence of TT. The number of recurrent cases found will lead to categorisation of the TT surgeon to either “high recurrence” or “low recurrence” with reasonable confidence. The threshold of unacceptability can be set by individual programmes according to previous local studies of recurrence rates or those from similar settings. Identification of surgeons delivering unacceptably high levels of recurrent TT will guide managers on the need for remedial intervention such as re-training. PMID:20881027

  18. Radiation Dosimetry Management: Quality Assurance and Investigations

    International Nuclear Information System (INIS)

    Perle, S.

    2001-01-01

    Full text: In a litigation-prone society, it is prudent for any business to evaluate its potential exposure to legal action, initiated by either an employee or a member of the general public. This potential is exacerbated when the phobia of radiation exposure and radioactive materials is interjected into the equation. This phobia is fuelled by the perceived risks of radiation exposure, be they fact or fantasy. With the current cancer incidence rate being approximately 1 in every 2.5 individuals (for all types of cancer), it is imperative that all facilities take a proactive look at their business vulnerability. When radiation exposure is the issue, records documentation is a critical factor, and a significant amount of effort should be expended to implement a comprehensive records management system. A comprehensive Radiation Dosimetry Management Program is essential if a business is going to mitigate any regulatory or legal intervention. This lecture will address appropriate Records Quality Assurance, and, the appropriate requirements for investigations of dosimetry results. (author)

  19. Quality assurance in trichiasis surgery: a methodology.

    Science.gov (United States)

    Buchan, John C; Limburg, Hans; Burton, Matthew J

    2011-03-01

    Trachoma remains a significant cause of blindness in many parts of the world. The major route to blindness involves upper lid entropion leading to trachomatous trichiasis (TT), which promotes progressive corneal opacification. The provision of surgery to correct TT in the populations most severely affected is a major challenge for the global effort to eliminate trachoma blindness by the year 2020. Most attention has focused on increasing the quantity of TT surgery performed, and large numbers of non-doctor operators have been trained to this end. Surgical audit by those performing TT surgery is not a routine part of any national trachoma control programme, and no effective mechanism exists for identifying surgeons experiencing poor outcomes. The authors propose a methodology for surgical audit at the level of the individual surgeon based on Lot Quality Assurance. A set number of patients operated on previously for upper eyelid TT are examined to detect the recurrence of TT. The number of recurrent cases found will lead to categorisation of the TT surgeon to either 'high recurrence' or 'low recurrence' with reasonable confidence. The threshold of unacceptability can be set by individual programmes according to previous local studies of recurrence rates or those from similar settings. Identification of surgeons delivering unacceptably high levels of recurrent TT will guide managers on the need for remedial intervention such as retraining.

  20. Quality assurance for radiodiagnostic equipment in Uruguay

    International Nuclear Information System (INIS)

    Cotelo, Elena D.

    2001-01-01

    Since Uruguay did not have an study on X-ray equipment, students of Radiation Protection course (RP) made this field work throughout the country. The objective is to obtain information on the number and kind of X-ray radiodiagnostic equipment. Some of the results are: there are 666 radiodiagnostic equipment. The ratio of population to equipment is 4.515 to 1 in the capital and the mean rate in the rest of the country is 4.383 to one, with a minimum of 1.707 and a maximum of 8.220. The Public Health Ministry (MSP) and the Instituciones de Asistencia Medica Colectiva (a kind of private heath assurance) (IAMC) have less equipment in the capital than in the rest of the country. The 37% of the capital population receives assistance through the IAMC , with a 42.5 % of the equipment. Uruguay except the capital has 18 districts and 17 computed tomography equipment, from which only 3 belong to the MSP. Five districts do not have any. In Montevideo, there are 11.500 females over forty years of age per X-ray mammography equipment, and this relation in the rest of the country is 13.900. There are 21 X-ray Interventional radiology equipment, 16 of them are in the capital. Is from relating the radiodiagnostic equipment, the population and the procedures, that quality assistance indicators emerge. This owns high importance on the way to create a RP National Programme. (author)

  1. General rules applicable to quality assurance

    International Nuclear Information System (INIS)

    1981-11-01

    RFS or Regles Fondamentales de Surete (Basic Safety Rules) applicable to certain types of nuclear facilities lay down requirements with which compliance, for the type of facilities and within the scope of application covered by the RFS, is considered to be equivalent to compliance with technical French regulatory practice. The object of the RFS is to take advantage of standardization in the field of safety, while allowing for technical progress in that field. They are designed to enable the operating utility and contractors to know the rules pertaining to various subjects which are considered to be acceptable by the Service Central de Surete des Installations Nucleaires, or the SCSIN (Central Department for the Safety of Nuclear Facilities). These RFS should make safety analysis easier and lead to better understanding between experts and individuals concerned with the problems of nuclear safety. The SCSIN reserves the right to modify, when considered necessary, any RFS and specify, if need be, the terms under which a modification is deemed retroactive. The aim of this rule is to define a series of measures to meet these general regulatory equipments. By applying this rule, the quality assurance code of practice for nuclear power plant safety, established by the International Atomic Energy Agency (I.A.E.A.), is considered to be observed

  2. The ARPANSA quality assurance program for radiopharmaceuticals

    International Nuclear Information System (INIS)

    Baldas, J.; Ivanov, Z.

    2003-01-01

    Full text: The Australian Radiation Protection and Nuclear Safety Agency (ARPANSA) conducts a radiopharmaceutical quality assurance test program in which radiopharmaceuticals used in nuclear medicine in Australia are tested for compliance with specifications. Where the radiopharmaceutical is the subject of a monograph in the British Pharmacopoeia or the European Pharmacopoeia, then the specifications given in these Pharmacopoeias are adopted. Where a monograph is only available in the US Pharmacopoeia, then this specification is generally adopted. In other cases the specifications quoted have been adopted by this Agency. Animal biodistribution testing was discontinued in 1997 due to resource limitation. Samples for testing were obtained through commercial channels. All technetium-99m cold kits were reconstituted according to the directions in the package insert using Sodium Pertechnetate [ 99m Tc] injection. The results of testing conducted by the ARPANSA during 1984-1999 are summarised. A significant cause of failure to meet full specifications has been due to non-compliance of the vial/package labels. Copyright (2003) The Australian and New Zealand Society of Nuclear Medicine Inc

  3. Manual on quality assurance programme auditing

    International Nuclear Information System (INIS)

    1984-01-01

    The objective of this Manual is to provide guidance and illustrative examples of the methodology and techniques of internal and external audits that are consistent with the requirements and recommendations of the Code and the Safety Guide. The methodology and techniques are based on the practices of Member States having considerable experience in auditing QA programmes. This Manual is directed primarily towards QA programme auditors and managers and presents methods and techniques considered appropriate for the preparation and performance of audits and the evaluation of results. Its scope includes the techniques and methods used to carry out QA programme audits variously described as 'System', 'Product' and 'Process' audits. The techniques and methods described here may be used as one approach to the evaluation of suppliers' QA capabilities as defined in 50-SG-QA10. Although the Manual is primarily directed towards purchasers and suppliers, it is also relevant to regulatory organizations, such as government offices responsible for quality assurance, which carry out external audits independent of purchasers and suppliers. In such cases similar methods, procedures and techniques may be used

  4. QART - the CERN facility for quality assurance

    CERN Multimedia

    Katarina Anthony

    2011-01-01

    How would your detector perform in a very high magnetic field? Or at 60°C and high humidity? Will it work for 10 or more years? Answering these questions requires specialised and thorough testing. This can be done at the Quality Assurance and Reliability Testing Laboratory (QART) - a top-notch testing facility based at CERN, providing invaluable support for CERN projects. The QART lab has become a service in 2011, and invites all projects to use its equipment and expertise.   A portable high-sensitivity infra-red thermal imaging video camera (top left) is used to observe the thermal profile of a silicon strip sensor (top right). The thermal images taken before (bottom left) and after (bottom right) applying voltage to the device clearly show a hot spot developing on the sensor, indicating a serious defect. The infra-red camera is an example of the variety of sophisticated equipment in the QART lab available to CERN projects for the analysis of problems and enviro...

  5. Quality assurance for radon measurements in Germany

    International Nuclear Information System (INIS)

    Beck, T.R.; Buchroeder, H.; Foerster, E.; Schmidt, V.

    2005-01-01

    Full text: Radiation protection regarding work activities at workplaces with naturally occurring radiation has been regulated in the German Radiation Protection Ordinance. Regulations refer only to workplaces where the presence of natural radiation leads to a significant increase in the exposure of workers. These workplaces were identified in the following working areas with enhanced exposures to radon-222: underground mines, including visitor mines and show caves; radon-spas and galleries; water supply and distribution industries. Presently, regulations are being initiated by the German government to limit the exposures to radon in homes. For radon measurements at workplaces passive radon devices for individual monitoring as well as active measuring systems for workplace monitoring can be used. However, passive radon devices are preferred for radon measurements in homes because of low costs and availability in large quantities. To assure the quality of radon measurements the German Federal Office for Radiation Protection (BfS) has established annual interlaboratory comparisons for passive radon devices. The comparisons are carried out in the BfS radon calibration laboratory accredited by the German Calibration Service. Passive radon devices which use solid state track detectors, electrets or activated charcoal can be submitted. Approved radon services which offer radon measurements to determine radon exposure in homes and at workplaces have to pass the comparisons successfully. (author)

  6. Computerized portable microwave hyperthermia quality assurance kit

    International Nuclear Information System (INIS)

    Cheung, A.Y.; Neyzari, A.

    1985-01-01

    A computerized quality assurance kit to provide precise measurement and calibration of microwave power and temperature, as well as capabilities to map SAR (Specific absorption rate) distribution in phantoms; and survey of hazardous microwave leakage has been designed. The kit is also capable of performing corelation studies on the relationship between SAR and net microwave power delivered at various anatomical sites. The kit consists of a portable microcomputer, a time-multiplexed A/D converter, a 4-channel dual directional microwave power monitor, a 4-channel thin-wire thermocouple thermometry system, an electronic thermal calibrator, a microwave leakage hazard survey meter, and a dynamic phantom tank for dosimetric analysis. Comparative performance studies were made against NBS-traceable power and temperature standards, non-perturbing optical temperature sensors, and established power and temperature measurement devices. The test results indicate that this instrument is providing its user with measurement accuracy of 0.1 0 C in temperature, 10% accuracy in power. The thin-wire thermocouple, with computer assisted error compensation, performs equally well in a strong microwave field in comparison with non-perturbing optical temperature sensors

  7. Quality assurance of a helical tomotherapy machine

    International Nuclear Information System (INIS)

    Fenwick, J D; Tome, W A; Jaradat, H A; Hui, S K; James, J A; Balog, J P; DeSouza, C N; Lucas, D B; Olivera, G H; Mackie, T R; Paliwal, B R

    2004-01-01

    Helical tomotherapy has been developed at the University of Wisconsin, and 'Hi-Art II' clinical machines are now commercially manufactured. At the core of each machine lies a ring-gantry-mounted short linear accelerator which generates x-rays that are collimated into a fan beam of intensity-modulated radiation by a binary multileaf, the modulation being variable with gantry angle. Patients are treated lying on a couch which is translated continuously through the bore of the machine as the gantry rotates. Highly conformal dose-distributions can be delivered using this technique, which is the therapy equivalent of spiral computed tomography. The approach requires synchrony of gantry rotation, couch translation, accelerator pulsing and the opening and closing of the leaves of the binary multileaf collimator used to modulate the radiation beam. In the course of clinically implementing helical tomotherapy, we have developed a quality assurance (QA) system for our machine. The system is analogous to that recommended for conventional clinical linear accelerator QA by AAPM Task Group 40 but contains some novel components, reflecting differences between the Hi-Art devices and conventional clinical accelerators. Here the design and dosimetric characteristics of Hi-Art machines are summarized and the QA system is set out along with experimental details of its implementation. Connections between this machine-based QA work, pre-treatment patient-specific delivery QA and fraction-by-fraction dose verification are discussed

  8. Quality assurance for IAEA inspection planning

    International Nuclear Information System (INIS)

    Markin, J.T.

    1986-01-01

    Under the provisions of the Treaty on Nonproliferation of Nuclear Weapons and other agreements with states, the International Atomic Energy Agency (IAEA) conducts inspections at nuclear facilities to confirm that their operation is consistent with the peaceful use of nuclear material. The Department of Safeguards at the IAEA is considering a quality assurance program for activities related to the planning of these facility inspections. In this report, we summarize recent work in writing standards for planning inspections at the types of facilities inspected by the IAEA. The standards specify the sequence of steps in planning inspections, which are: (1) administrative functions, such as arrangements for visas and travel, and communications with the state to confirm facility operating schedules and the state's acceptance of the assigned inspectors; (2) technical functions including a specification of the required inspection activities, determination of personnel and equipment resources, and a schedule for implementing the inspection activities at the facility; and (3) management functions, such as pre- and post-inspection briefings, where the planned and implemented inspection activities are reviewed

  9. AVLIS Production Plant Preliminary Quality Assurance Plan and Assessment

    International Nuclear Information System (INIS)

    1984-01-01

    This preliminary Quality Assurance Plan and Assessment establishes the Quality Assurance requirements for the AVLIS Production Plant Project. The Quality Assurance Plan defines the management approach, organization, interfaces, and controls that will be used in order to provide adequate confidence that the AVLIS Production Plant design, procurement, construction, fabrication, installation, start-up, and operation are accomplished within established goals and objectives. The Quality Assurance Program defined in this document includes a system for assessing those elements of the project whose failure would have a significant impact on safety, environment, schedule, cost, or overall plant objectives. As elements of the project are assessed, classifications are provided to establish and assure that special actions are defined which will eliminate or reduce the probability of occurrence or control the consequences of failure. 8 figures, 18 tables

  10. Quality assurance for packaging of radioactive and hazardous materials

    International Nuclear Information System (INIS)

    Gustafson, L.D.

    1986-01-01

    The Department of Energy (DOE) has required for many years that quality assurance programs be established and implemented for the packaging of radioactive and hazardous materials. This paper identifies various requirement principles and related actions involved in establishing effective quality assurance for packaging of radioactive and hazardous materials. A primary purpose of these quality assurance program activities is to provide assurance that the packaging and transportation of hazardous materials, which includes radioactive and fissile materials, are in conformance with appropriate governmental regulations. Applicable regulations include those issued by the Nuclear Regulatory Commission (NRC), the Department of Transportation (DOT), and the Environmental Protection Agency (EPA). DOE Order 5700.6A establishes that quality assurance requirements are to be applied in accordance with national consensus standards where suitable ones are available. In the nuclear area, ANSI/ASME NQA-1 is the preferred standard

  11. Quality assurance and quality control in mammography: A review

    International Nuclear Information System (INIS)

    BenComo, Jose A.

    2000-01-01

    A mammogram is among the most technically demanding radiographic procedures. The early detection of breast cancer relies on the radiologist's ability to perceive subtle changes in the image that are only perceptible with high-quality imaging. Early detection of breast cancer is only as reliable as the mammogram with which a diagnosis is made, and a mammogram is only as accurate as the system that produces it. A quality assurance (QA) program maximizes the likelihood that the mammographic images will provide adequate diagnostic information for the least possible radiation exposure and cost to the patient. The QA program monitors each phase of operation of the imaging facility beginning with the request for an examination and ending with the interpretation of the referring physician and ensures that the imaging equipment used for the examination will yield the information desired. Because image quality is the most important technical aspect of mammography, this review summarizes the most important QA and quality control issues

  12. Quality assurance network: The European pilot study

    International Nuclear Information System (INIS)

    Chavaudra, J.; Derreumaux, S.; Brider, A.

    1996-01-01

    Based on the IAEA/WHO experience in mailed dosimetry, a Quality Assurance (QA) Network, sponsored by the EC committee ''Europe against Cancer'', has been set up in 1991 for all European centres. Besides a survey of radiotherapy infrastructure, the project includes three measurement steps: primarily, a check of beam output and quality in reference conditions with a mailed TLD-procedure, in a second step, the mailed verification of other beam data and dose calculation procedures with multipurpose phantom, and finally in vivo dosimetry at the individual patient levels with mailed dosimeters. The results concerning 162 beams from 85 centres are analysed (58 60 Co beams and 104 X-ray beams). 27 beams present minor deviations (3 to 6%) and 15 beams (4/58 60 Co beams and 11/104 X-ray beams) from 11 centres present major deviations (≥ 6%). The analysis shows that 17/27 minor deviations and all major deviations have been detected in centres which have not benefited from an external check during the last five years; in 14 out of 15 large deviations, the measured dose is smaller than the stated dose. In most centres with major deviation, the physicists did not have the necessary experience and did not calibrate regularly the beams. In 6 centres out of 11 there was no dosimeter or the dosimeter available has not been calibrated recently. In 3 centres, the physicist did not give any explanations. The conclusions concerning the second step (multipurpose phantom), outline the larger magnitude of the deviations for off axis points, oblique surface and the use of wedge filters. (author). 32 refs, 7 figs, 2 tabs

  13. Quality assurance network: The European pilot study

    Energy Technology Data Exchange (ETDEWEB)

    Chavaudra, J; Derreumaux, S; Brider, A [Institut Gustave Roussa, Villejuif (France). Service de Physique; Dutreix, A; Schueren, E van der [University Hospital, Leuven (Belgium)

    1996-08-01

    Based on the IAEA/WHO experience in mailed dosimetry, a Quality Assurance (QA) Network, sponsored by the EC committee ``Europe against Cancer``, has been set up in 1991 for all European centres. Besides a survey of radiotherapy infrastructure, the project includes three measurement steps: primarily, a check of beam output and quality in reference conditions with a mailed TLD-procedure, in a second step, the mailed verification of other beam data and dose calculation procedures with multipurpose phantom, and finally in vivo dosimetry at the individual patient levels with mailed dosimeters. The results concerning 162 beams from 85 centres are analysed (58 {sup 60}Co beams and 104 X-ray beams). 27 beams present minor deviations (3 to 6%) and 15 beams (4/58 {sup 60}Co beams and 11/104 X-ray beams) from 11 centres present major deviations ({>=} 6%). The analysis shows that 17/27 minor deviations and all major deviations have been detected in centres which have not benefited from an external check during the last five years; in 14 out of 15 large deviations, the measured dose is smaller than the stated dose. In most centres with major deviation, the physicists did not have the necessary experience and did not calibrate regularly the beams. In 6 centres out of 11 there was no dosimeter or the dosimeter available has not been calibrated recently. In 3 centres, the physicist did not give any explanations. The conclusions concerning the second step (multipurpose phantom), outline the larger magnitude of the deviations for off axis points, oblique surface and the use of wedge filters. (author). 32 refs, 7 figs, 2 tabs.

  14. Quantitative research versus quality assurance, quality improvement, total quality management, and continuous quality improvement.

    Science.gov (United States)

    Vogelsang, J

    1999-04-01

    The purpose of this report is to provide a review of the scientific method used in the quantitative research studies for consumers, evaluators, and applied nurse researchers. The fundamental characteristics of the problem-solving/ performance-improvement processes of quality assurance, quality improvement, total quality management, and continuous quality improvement are described. Research is compared with these processes, and is followed by a discussion about the publication of quantitative research findings.

  15. QAM: PROPOSED MODEL FOR QUALITY ASSURANCE IN CBSS

    Directory of Open Access Journals (Sweden)

    Latika Kharb

    2015-08-01

    Full Text Available Component-based software engineering (CBSE / Component-Based Development (CBD lays emphasis on decomposition of the engineered systems into functional or logical components with well-defined interfaces used for communication across the components. Component-based software development approach is based on the idea to develop software systems by selecting appropriate off-the-shelf components and then to assemble them with a well-defined software architecture. Because the new software development paradigm is much different from the traditional approach, quality assurance for component-based software development is a new topic in the software engineering research community. Because component-based software systems are developed on an underlying process different from that of the traditional software, their quality assurance model should address both the process of components and the process of the overall system. Quality assurance for component-based software systems during the life cycle is used to analyze the components for achievement of high quality component-based software systems. Although some Quality assurance techniques and component based approach to software engineering have been studied, there is still no clear and well-defined standard or guidelines for component-based software systems. Therefore, identification of the quality assurance characteristics, quality assurance models, quality assurance tools and quality assurance metrics, are under urgent need. As a major contribution in this paper, I have proposed QAM: Quality Assurance Model for component-based software development, which covers component requirement analysis, component development, component certification, component architecture design, integration, testing, and maintenance.

  16. Service quality improvement of ground staff at Don Mueang International Airport

    Directory of Open Access Journals (Sweden)

    Sittichai Sricharoenpramong

    2018-01-01

    Full Text Available The purposes of this research were to: 1 evaluate the service quality of the ground staff at Don Mueang International Airport (DMK, 2 compare the ground staff quality service perception of Thai passengers at DMK, and 3 provide guidelines for service quality improvement of the DMK airlines ground staff. A sample size of 400 Thai domestic passengers was accidentally selected at DMK. A questionnaire was used as a research tool for data collection. Five dimensions of service quality were evaluated: reliability, responsiveness, assurance, empathy, and tangibles. It was found that the service quality of ground staff was moderate. The highest dimension of service quality realization was tangibles, followed successively by reliability, assurance, empathy, and responsiveness. The passengers' perception of the ground staff's service quality varied by gender and age group. Guidelines were proposed for the improvement of ground staff service quality at DMK based on the findings. Keywords: airport, ground staff, quality of service

  17. The Columbia River Protection Supplemental Technologies Quality Assurance Project Plan

    International Nuclear Information System (INIS)

    Fix, Anne

    2007-01-01

    The U.S. Department of Energy (DOE) has conducted interim groundwater remedial activities on the Hanford Site since the mid-1990s for several groundwater contamination plumes. DOE established the Columbia River Protection Supplemental Technologies Project (Technologies Project) in 2006 to evaluate alternative treatment technologies. The objectives for the technology project are as follows: develop a 300 Area polyphosphate treatability test to immobilize uranium, design and test infiltration of a phosphate/apatite technology for Sr-90 at 100-N, perform carbon tetrachloride and chloroform attenuation parameter studies, perform vadose zone chromium characterization and geochemistry studies, perform in situ biostimulation of chromium studies for a reducing barrier at 100-D, and perform a treatability test for phytoremediation for Sr-90 at 100-N. This document provides the quality assurance guidelines that will be followed by the Technologies Project. This Quality Assurance Project Plan is based on the quality assurance requirements of DOE Order 414.1C, Quality Assurance, and 10 CFR 830, Subpart A--Quality Assurance Requirements as delineated in Pacific Northwest National Laboratory?s Standards-Based Management System. In addition, the technology project is subject to the Environmental Protection Agency (EPA) Requirements for Quality Assurance Project Plans (EPA/240/B-01/003, QA/R-5). The Hanford Analytical Services Quality Assurance Requirements Documents (HASQARD, DOE/RL-96-68) apply to portions of this project and to the subcontractors. HASQARD requirements are discussed within applicable sections of this plan.

  18. Quality assurance in nuclear fuel element component supply

    International Nuclear Information System (INIS)

    Jenkins, B.P.

    1987-01-01

    The paper describes the application of Quality Assurance to nuclear fuel element component supply. The Quality Assurance programme includes integrated procurement, purchasing, surveillance and receipt inspection functions. Purchasing policy is based on a consistent preference for competitive tendering. Multiple sourcing is used to encourage competitive pricing and increase security of supply. A receipt inspection facility is maintained to ensure the high product quality levels demanded by the nuclear industry. (U.K.)

  19. Quality assurance inspections in the transportation packaging supplier industry

    International Nuclear Information System (INIS)

    Jankovich, J.P.

    1991-01-01

    In this paper the quality assurance inspections of the transportation packaging supplier industry, conducted by the U.S. Nuclear Regulatory Commission (NRC) on a routine basis since 1989 are discussed. The term supplier is used to include designers, fabricators, and distributors that hold NRC approved Quality Assurance Programs and Certificates of Compliance for packagings to transport radioactive materials. The objective of the inspections is to provide assurance that transportation packagings are fabricated and procured in accordance with 10 CFR Parts 21 and 71 requirements. The inspections are conducted in a systematic and comprehensive manner, utilizing uniform inspection techniques in order to assure uniformity and comparability. During the April 1989 and May 1991 period approximately 21 inspections were conducted by the Transportation Branch, Office of Nuclear Material Safety and Safeguards of the NRC. The majority of the findings were identified in the areas of quality assurance procedures, control of special processes (e.g. welding, radiography), and maintenance of QA records

  20. Quality Assurance and Quality Control in TLD Measurement

    International Nuclear Information System (INIS)

    Bhuiyan, S.I.; Qronfla, M.M.; Abulfaraj, W.H.; Kinsara, A.A.; Taha, T.M.; Molla, N.I.; Elmohr, S.M.

    2008-01-01

    TLD technique characterized by high precision and reproducibility of dose measurement is presented by addressing pre-readout annealing, group sorting, dose evaluation, blind tests, internal dose quality audit and external quality control audits. Two hundred and forty TLD chips were annealed for 1 hour at 4000 degree C followed by 2 h at 1000 degree C. After exposure of 1 mGy from 90 Sr irradiator TLDs were subjected to pre-readout annealing at 1000 degree C, then readout, sorted into groups each with nearly equal sensitivity. Upon repeating the procedures, TLDs having response >3.5% from group mean were dropped to assuring group stability. Effect of pre-readout annealing has been studied. Series of repeated measurements were conducted to stabilize calibration procedures and DCF generation using SSDL level 137 Cs calibrator, dose master, ionization chambers. Performed internal dose quality audits, blind tests and validated by external QC tests with King Abdulaziz City of Science and Technology

  1. Delivery quality assurance with ArcCHECK

    International Nuclear Information System (INIS)

    Neilson, Christopher; Klein, Michael; Barnett, Rob; Yartsev, Slav

    2013-01-01

    Radiation therapy requires delivery quality assurance (DQA) to ensure that treatment is accurate and closely follows the plan. We report our experience with the ArcCHECK phantom and investigate its potential optimization for the DQA process. One-hundred seventy DQA plans from 84 patients were studied. Plans were classified into 2 groups: those with the target situated on the diodes of the ArcCHECK (D plans) and those with the target situated at the center (C plans). Gamma pass rates for 8 target sites were examined. The parameters used to analyze the data included 3%/3 mm with the Van Dyk percent difference criteria (VD) on, 3%/3 mm with the VD off, 2%/2 mm with the VD on, and x/3 mm with the VD on and the percentage dosimetric agreement “x” for diode plans adjusted. D plans typically displayed maximum planned dose (MPD) on the cylindrical surface containing ArcCHECK diodes than center plans, resulting in inflated gamma pass rates. When this was taken into account by adjusting the percentage dosimetric agreement, C plans outperformed D plans by an average of 3.5%. ArcCHECK can streamline the DQA process, consuming less time and resources than radiographic films. It is unnecessary to generate 2 DQA plans for each patient; a single center plan will suffice. Six of 8 target sites consistently displayed pass rates well within our acceptance criteria; the lesser performance of head and neck and spinal sites can be attributed to marginally lower doses and increased high gradient of plans

  2. The Marshall Islands radioassay quality assurance program. An overview

    International Nuclear Information System (INIS)

    Hamilton, T.F.; Robison, W.L.; Kehl, S.; Stoker, A.C.; Conrado, C.L.

    2000-01-01

    An extensive quality assurance program to provide high quality data and assessments in support of the Marshall Islands Dose Assessment and Radioecology Program has been developed the Lawrence Livermore National Laboratory. Quality assurance objectives begin with the premise of providing integrated and cost-effective program support (to meet wide-ranging programmatic needs, scientific peer review, and build public confidence) and continue through from design and implementation of large-scale field programs, sampling and sample preparation, radiometric and chemical analyses, documentation of quality assurance/quality control practices, exposure assessments, and dose/risk assessments until publication. The basic structure of the radioassay quality assurance/quality control program can be divided into four essential elements: (1) sample and data integrity control, (2) instrument validation and calibration, (3) method performance testing, validation, development and documentation, and (4) periodic peer review and on-site assessments. While the quality assurance objectives are tailored towards a single research program and the evaluation of major exposure pathways/critical radionuclides pertinent to the Marshall Islands, quality assurance practices that are consistent with proposed criteria designed for laboratory accreditation were attempted to be developed. (author)

  3. Physical aspects of quality assurance in cobalt teletherapy units

    Energy Technology Data Exchange (ETDEWEB)

    Ng, Kwan Hong [Malaya Univ., Kuala Lumpur (Malaysia)

    1989-06-01

    ICRU Report No. 24 states that +- 5% is a reasonable degree of accuracy to strive for in the delivery of absorbed doses to target volumes in radiotherapy. To achieve this quality assurance level, a comprehensive programme comprising both physical and clinical components is needed. The purpose of this paper is to present the rationale and guidelines for implementing a recommended quality assurance programme. It will emphasize the physical aspects pertaining to acceptance and constancy tests using Cobalt-60 teletherapy units. It will also outline a suggested schedule of quality assurance testings including radiation dosimetry, geometry and electrochemical safety. (author).

  4. Traps in quality assurance of diagnostic X-ray equipment

    International Nuclear Information System (INIS)

    Meier, N.; Lenzen, H.; Fiebich, M.

    1992-01-01

    With the introduction of the German industrial protocol for quality assurance of X-ray equipment, everybody using X-ray machines fell into sort of trap or found some of the procedures misleading. Vigorous discussions were held on every conceivable aspect of this and other protocols, and are still in progress. This paper points out some of the common traps and considers a new type dosimeter, which allows a definite separation of quality assurance of X-ray equipment and of processing and which can also be used in future for quality assurance of digital radiography equipment. (orig.) [de

  5. Quality Assurance Tests of the CMS Endcap RPCs

    CERN Document Server

    Ahmed, Ijaz; Hamid Ansari, M; Irfan Asghar, M; Asghar, Sajjad; Awan, Irfan Ullah; Butt, Jamila; Hoorani, Hafeez R; Hussain, Ishtiaq; Khurshid, Taimoor; Muhammad, Saleh; Shahzad, Hassan; Aftab, Zia; Iftikhar, Mian; Khan, Mohammad Khalid; Saleh, M

    2008-01-01

    In this note, we have described the quality assurance tests performed for endcap Resistive Plate Chambers (RPCs) at two different sites, Pakistan Atomic Energy Commission (PAEC) and National Centre for Physics (NCP), in Pakistan. This paper describes various quality assurance tests both at the level of gas gaps and the chambers. The data has been obtained at different time windows during the large scale production of CMS RPCs of RE2/2 and RE2/3 type. In the quality assurance tests, we have investigated parameters like dark current, strip occupancy, cluster size and efficiency of RPCs.

  6. Quality assurance of EDP software in practical application

    International Nuclear Information System (INIS)

    Winkler, H.

    1982-01-01

    Alongside the specific properties of the soft software, it is mainly points outside the traditional testing field which apply for the quality assurance thereof. Measures for quality assurance must in particular, start in the development. This presupposes a partial-result orientated development process of software. Due to the high qualitative demands, implements for testing and inspection are of great importance. The problems in software quality assurance are typical for a young technical field where the necessity of which is indisputed, but which has to effect on an empirical-pragmatical level still, due to insufficient scientific foundation. (orig.) [de

  7. Quality assurance measures for spent fuel shipping and storage containers

    International Nuclear Information System (INIS)

    Droste, B.; Roedel, R.

    1987-01-01

    Quality assurance measures are to be applied in production and operation to ensure the approved fuel-element-container design specifications. The authors concentrate on the official regulations pertaining to the application of a quality assurance system, on the compliance with design specifications ensured by certified manufacturing tests and in-service inspections. For nodular-cast-iron container bodies, the authors demonstrate the procedure by presenting the contents of the materials data sheet characterizing the material, and the production and test sequence plan for container casting. In addition, they state the quality assurance requirements for interim-storage containers which transgress those stipulated for shipping containers. (orig.) [de

  8. Quality assurance as a management tool in decommissioning activities

    International Nuclear Information System (INIS)

    Arter, D.R.

    1982-01-01

    Quality assurance practices have been applied to the peaceful use of nuclear energy for many years. These practices are just as useful to the back end of the nuclear energy cycle as they are to the front end. The Department of Energy requires the application of quality assurance to all of its projects and programs. Quality assurance as a management tool consists of three fundamental elements: planning, execution and control. These elements should be applied to decommissioning activities by all parties, such that limited funds are wisely spent and the public is adequately protected

  9. Implementation of benchmark management in quality assurance audit activities

    International Nuclear Information System (INIS)

    Liu Yongmei

    2008-01-01

    The concept of Benchmark Management is that the practices of the best competitor are taken as benchmark, to analyze and study the distance between that competitor and the institute, and take efficient actions to catch up and even exceed the competitor. This paper analyzes and rebuilds all the process for quality assurance audit with the concept of Benchmark Management, based on the practices during many years of quality assurance audits, in order to improve the level and effect of quality assurance audit activities. (author)

  10. 'The use of technical specialists in quality assurance audits'

    International Nuclear Information System (INIS)

    Higgins, T.J.; Diaz, M.R.

    1993-01-01

    This paper provides a nontechnical discussion of the use of Technical Specialists in quality assurance audits by the Office of Civilian Radioactive Waste Management's Office of Quality Assurance. The purpose is to describe one successful solution to the problem that arises when a quality assurance organization is responsible for conducting audits of many, diverse, highly technical activities. The solution is the conduct of audits that combine both horizontal and vertical sample selection strategies and which employ Technical Specialists in the vertical portion of the audit. The Technical Specialist is paired with a programmatic auditor who perform as a dedicated team in their conduct of the audit. This paper focuses on the Technical Specialist

  11. Quality assurance feedback as a nursing management strategy.

    Science.gov (United States)

    Brannon, D; Bucher, J A

    1989-01-01

    Quality assurance and effective nurse management can be viewed as intersecting goals. Objective feedback derived from quality assurance data is a potentially powerful means of enhancing nurses' performance and job satisfaction. The use of automated information systems to provide such direct feedback offers the additional advantage of recognizing nurses as self-monitoring, self-correcting professionals. The need, opportunity, and challenge involved in meshing quality assurance with human resource management through computer-generated feedback are discussed in the context of the home health care setting.

  12. Quality Assurance Plan, N springs expedited response action

    International Nuclear Information System (INIS)

    Jackson, G.J.

    1994-01-01

    This document is the Quality Assurance Plan (QAP) to be followed during the definitive design, construction, and operational phases for activities associated with the N Springs Expedited Response Action (ERA) for the 100-NR-2 Operable Unit (OU). Westinghouse Hanford Company (WHC) will comply with the US Department of Energy (DOE) Order 5700.6C, Quality Assurance (DOE 1989), and the US Environmental Protection Agency (EPA), EPA/530-SW-86-031, Technical Guidance Document: Construction Quality Assurance for Hazardous Waste Land Disposal Facilities (EPA 1986)

  13. Quality Assurance Programme for Computed Tomography: Diagnostic and Therapy Applications

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2012-08-15

    This publication presents a harmonized approach to quality assurance in the field of computed tomography applied to both diagnostics and therapy. It gives a careful analysis of the principles and specific instructions that can be used for a quality assurance programme for optimal performance and reduced patient dose in diagnostic radiology. In some cases, radiotherapy programmes are making a transition from 2-D to 3-D radiotherapy, a complex process which critically depends on accurate treatment planning. In this respect, the authors also provide detailed information about the elements needed for quality assurance testing, including those relating to accurate patient characterization as needed for radiotherapy treatment planning.

  14. On-site quality assurance during erection of a nuclear power plant

    International Nuclear Information System (INIS)

    Mueller, J.

    1976-01-01

    The paper deals with general quality assurance measures, the quality assurance during on-site production (incoming inspection, inspection of welds and welding equipment) and describes in more detail the quality assurance procedures for the containment. (RW) [de

  15. Quality assurance: Importance of systems and standard operating procedures

    Directory of Open Access Journals (Sweden)

    Kishu Manghani

    2011-01-01

    Full Text Available It is mandatory for sponsors of clinical trials and contract research organizations alike to establish, manage and monitor their quality control and quality assurance systems and their integral standard operating procedures and other quality documents to provide high-quality products and services to fully satisfy customer needs and expectations. Quality control and quality assurance systems together constitute the key quality systems. Quality control and quality assurance are parts of quality management. Quality control is focused on fulfilling quality requirements, whereas quality assurance is focused on providing confidence that quality requirements are fulfilled. The quality systems must be commensurate with the Company business objectives and business model. Top management commitment and its active involvement are critical in order to ensure at all times the adequacy, suitability, effectiveness and efficiency of the quality systems. Effective and efficient quality systems can promote timely registration of drugs by eliminating waste and the need for rework with overall financial and social benefits to the Company.

  16. Quality Assurance in Post-Secondary Education: Some Common Approaches

    Science.gov (United States)

    Law, Dennis Chung Sea

    2010-01-01

    Purpose: The common approaches to quality assurance (QA), as practiced by most post-secondary education institutions for internal quality monitoring and most QA authorities for external quality monitoring (EQM), have been considered by many researchers as having largely failed to address the essence of educational quality. The purpose of this…

  17. Concrete and steel construction quality control and assurance

    CERN Document Server

    El-Reedy, Mohamed A

    2014-01-01

    Starting with the receipt of materials and continuing all the way through to the final completion of the construction phase, Concrete and Steel Construction: Quality Control and Assurance examines all the quality control and assurance methods involving reinforced concrete and steel structures. This book explores the proper ways to achieve high-quality construction projects, and also provides a strong theoretical and practical background. It introduces information on quality techniques and quality management, and covers the principles of quality control. The book presents all of the quality control and assurance protocols and non-destructive test methods necessary for concrete and steel construction projects, including steel materials, welding and mixing, and testing. It covers welding terminology and procedures, and discusses welding standards and procedures during the fabrication process, as well as the welding codes. It also considers the total quality management system based on ISO 9001, and utilizes numer...

  18. The role and relevance of quality assurance to quality control

    International Nuclear Information System (INIS)

    Churchill, G.F.

    1989-01-01

    The paper describes the development of Quality Assurance as a total management technique, incorporating manufacturing and construction Quality Control, to give confidence of satisfactory in-service performance. The application of QA to the Heysham 2 and Torness AGR projects design and construction is defined with particular reference to the development of a QA requirements specification, delegation of QA responsibility through the hierarchy of purchasers and suppliers of plant and material, the role of the QA organization and QA auditing. The paper discusses the effectiveness and benefits of QA and the problems identified in its application and implementation. The problems, their solutions and longer term improvements to reduce the costs of QA as well as enhancing confidence in the satisfactory performance of future nuclear projects, are described. (author)

  19. Quality Assurance in Defense Adjudication Workshop for Defining and Assessing Quality

    National Research Council Canada - National Science Library

    Carney, Ralph

    2003-01-01

    ...) can adopt to assure the quality of adjudication decisions. Subject matter experts identified adjudication customers, products and services, and customer expectations and defined adjudication quality...

  20. Quality Assurance in Defense Adjudication: Workshop for Defining and Assessing Quality

    National Research Council Canada - National Science Library

    Carney, Ralph

    2002-01-01

    ...) can adopt to assure the quality of adjudication decisions. Subject matter experts identified adjudication customers, products and services, and customer expectations and defined adjudication quality...

  1. Nevada Nuclear Waste Storage Investigations: Quality Assurance Plan

    International Nuclear Information System (INIS)

    1980-08-01

    The Nevada Nuclear Waste Storage Investigations (NNWSI) were established by DOE/NV to evaluate the geohydrologic setting and underground rock masses of the Nevada Test Site (NTS) and contiguous areas to determine whether a suitable site exists for constructing a repository for isolating highly radioactive solid wastes. Since the results of these evaluations will impact possible risks to public health and safety, a quality assurance program which conforms to the criteria given in the Code of Federal Regulations is needed to control the quality aspects of the work. This Quality Assurance Plan (QAP) describes the general quality assurance program for the overall NNWSI project under which the quality assurance programs of the individual participating organizations and support contractors are to operate. The details of how each of these groups will meet the criteria will differ among participating organizations and support contractors, and those details are given in the QAPP's listed in Appendix A. It is the purpose of this plan to show the commonality of quality assurance programs in effect within the project and to define how each element fits into the entire picture to give total quality assurance coverage for the NNWSI Project

  2. Quality assurance for the safe transport of radioactive material

    International Nuclear Information System (INIS)

    1994-01-01

    All activities related to the safe transport of radioactive material should be covered by a quality assurance programme. This publication recognizes that a single transport operation often involves several different organizations, each having specific responsibilities. Hence, it is unlikely that the operation will be covered by a single quality assurance programme. Each quality assurance programme should be tailored to the specific organizational structure for which the programme is prepared, with account taken of the particular transport activities of that organization and the interfaces with other organizations. The aim of this publication is to give a detailed interpretation of what must be done by whom to produce a quality assurance programme for radioactive material transport. This publication provides guidance on methods and practical examples to develop QA programmes for the safe transport of radioactive material. It provides information on how to develop the programme, the standards and the common features of a QA programme

  3. Quality assurance program : bituminous concrete and central mix aggregates.

    Science.gov (United States)

    1980-01-01

    This report presents the results of a pilot quality assurance program initiated in the Richmond District in 1978. Under this program the producer's control tests are used for the acceptance of central mix aggregate and bituminous concrete and the Dep...

  4. The role of quality assurance in the nuclear industry

    International Nuclear Information System (INIS)

    1985-01-01

    The paper reports on the proceedings of a one day conference on ''the role of quality assurance in the nuclear industry'', presented by the British Nuclear Forum Working Group on Quality Assurance, 1985. The conference reviews the application and effectiveness of the British Standards in the light of experience with the AGR programme, and considers the lessons learned that will benefit future projects. Seven papers are presented at the conference, of which five deal with the AGR experience with respect to quality assurance in design and manufacture. The remaining two papers examine quality assurance in computing software and building on the AGR experience. All seven papers are selected for INIS and indexed separately. (U.K.)

  5. Quality Assurance Project Plan for Citizen Science Projects

    Science.gov (United States)

    The Quality Assurance Project Plan is necessary for every project that collects or uses environmental data. It documents the project planning process and serves as a blueprint for how your project will run.

  6. Qinshan Phase III (CANDU) nuclear power project quality assurance

    International Nuclear Information System (INIS)

    Wang Lingen; Du Jinxiang

    2001-01-01

    The completion and implementation of quality assurance system of Qinshan Phase III (CANDU) nuclear power project are presented. Some comments and understanding with consideration of the project characteristics are put forward

  7. Teachers' motivation and its influence on quality assurance in the ...

    African Journals Online (AJOL)

    Motivational strategies like staff training and development, promotion, salary, remuneration, working conditions, status and participatory decision making, acted as a barrier towards achieving quality assurance in the educational system. Some challenges that negatively influenced teacher motivation and recommendations ...

  8. Quality assurance when documenting chemical hazards to health and environment

    International Nuclear Information System (INIS)

    Guttormsen, R.; Modahl, S.I.; Tufto, P.A.; Buset, H.

    1991-01-01

    In a joint project between The Norwegian Petroleum Directorate (NPD), the State Pollution Control Agency (SFT) and Conoco Norway Inc. (CNI) we have evaluated the use of quality assurance principles in connection with development and distribution of information about chemicals. Assuring quality of the documentation is first of all depending on: the work in international organizations; the content of national and international guidelines and criteria documents; the use of product registers; activities in manufacturers' organizations; the role of importers and agents. These are aspects which have been evaluated. Recommendations are given in this paper concerning: definition of responsibilities in regulations, standards and guidelines; feedback of experience and coordination through international work; application of quality assurance principles in the use of information technology in international organizations and in manufacturers' organizations; use of quality assurance principles in validation of data

  9. Food safety and quality assurance : foods of animal origin

    National Research Council Canada - National Science Library

    Hughes, Keith L; Hinton, Michael H; Hubbert, William T; Hagstad, Harry V; Spangler, Elizabeth

    1996-01-01

    The second edition of Food Safety and Quality Assurance is a basic reference for veterinarians, extension specialists, and others who help food-animal producers throughout the food chain to provide...

  10. Annual Quality Assurance Conference Files by Tom Mancuso

    Science.gov (United States)

    25th Annual Quality Assurance Conference. Abstract: Learn about the NEW EPA Method 325b for Refinery Fence Line Monitoring and TO-17 Extended for Soil Gas by Tom Mancuso and Abstract: Success Using Alternate Carrier Gases for Volatile Methods

  11. Master Pump Shutdown MPS Software Quality Assurance Plan (SQAP)

    International Nuclear Information System (INIS)

    BEVINS, R.R.

    2000-01-01

    The MPSS Software Quality Assurance (SQAP) describes the tools and strategy used in the development of the MPSS software. The document also describes the methodology for controlling and managing changes to the software

  12. Quality Assurance of Software Used In Aircraft Or Related Products

    Science.gov (United States)

    1993-02-01

    This advisory circular (AC) provides an acceptable means, but not the only means, to show compliance with the quality assurance requirements of Federal Aviation Regulations (FAR) Part 21, Certification Procedures for Products and Parts, as applicable...

  13. Application of quality assurance to MC and A systems

    International Nuclear Information System (INIS)

    Skinner, A.J.; Delvin, W.L.

    1986-01-01

    Application of the principles of quality assurance to MC and A has been done at DOE's Savannah River Operations Office. The principles were applied to the functions within the MC and A Branch, including both the functions used to operate the Branch and those used to review the MC and A activities of DOE/SR's contractor. The purpose of this paper is to discuss that application of quality assurance and to show how the principles of quality assurance relate to the functions of a MC and A system, for both a DOE field office and a contractor. The principles (presented as requirements from the NQA-1 standard) are briefly discussed, a method for applying quality assurance is outlined, application at DOE/SR is shown, and application to a contractor's MC and A system is discussed

  14. Quality assurance in the Foundation Phase in the Eastern Cape ...

    African Journals Online (AJOL)

    Erna Kinsey

    School principals should be involved in the quality assurance process at all levels .... The focus of the first function will be on the internal institution level itself, whilst the ..... speech therapy and remedial services can make a difference in the.

  15. 10 CFR 72.142 - Quality assurance organization.

    Science.gov (United States)

    2010-01-01

    ... activities are performed, the organizational structure for executing the quality assurance program may take... the required authority and organizational freedom. Irrespective of the organizational structure, the... functions of structures, systems, and components which are important to safety. These activities include...

  16. Quality assurance manual for the development of digital systems

    International Nuclear Information System (INIS)

    Lee, Cheol Kwon; Kwon, Kee Choon; You, Young Eun; Kim, Kwan Hyun; Park, Jung Woo; Park, Chan Seok

    2001-12-01

    A digital safety system is being developed by three companies under the Korea Nuclear I and C System R and D Program. This Quality Assurance Manual (QAM) is written to ensure the safety and reliability of the system and to meet the regulatory requirements associated with quality assurance. This QAM describes eighteen elements of quality assurance criteria required for the development of the system, which are coincident with the criteria specified in Nuclear Energy Laws and Enforcement Regulations of Nuclear Energy Laws and 10CFR50 Appendix B. This QAM is submitted to the regulatory body with other documents related to the quality assurance activities performed during the system development. And its safety, validity and fulfillment are reviewed and audited in the review process of topical report of the digital safety system

  17. quality assurance systems in nuclear fuel procurement and manufacturing

    International Nuclear Information System (INIS)

    Can, S.

    1997-01-01

    Quality is the totality of features and characteristics of a product or service that bear on its ability to satisfy stated or implied needs. Quality control is activities and techniques used to fulfill the requirements of quality. Quality assurance is a system and its main components are requirements. QA program, organization and responsibilities, design and verification, material and its control, manufacturing and process control, inspections, audits and documents: manuals, specifications, instructions. Quality assurance systems are largely based on ISO 9000 series of the International Standards Organization. ISO 9000 series has been adopted and published by Turkish Standards Institute as TS-ISO 9000. International Atomic Energy Agency also published a guide (50-SG-QA11) ''Quality Assurance in the Procurement, Design and Manufacture of Nuclear Fuel Assemblies'' in the safety guide series. In this study the role of quality control in quality assurance systems, inspection and test plans and acceptance and nonconformance quality levels will be explained in relation to nuclear fuel production. Examples of applications in quality assurance systems based on ISO 9000 will be given

  18. Code on the safety of nuclear power plants: Quality assurance

    International Nuclear Information System (INIS)

    1988-01-01

    This revised Code provides the principles and objectives for the establishment and implementation of quality assurance programmes applied to both the overall and each of the constituent activities associated with a nuclear power plant project. The quality assurance principles enumerated in the present Code can be usefully applied to nuclear facilities other than nuclear power plants. The quality assurance programme encompasses: (1) the activities that are necessary to achieve the appropriate quality of the respective item or service; and (2) the activities that are necessary for verifying that the required quality is achieved and that objective evidence is produced to that effect. Quality assurance is an essential aspect of good management and the quality assurance programme is the main management tool for a disciplined approach to all activities affecting quality, including, where appropriate, verification that each task has been satisfactorily performed and that necessary corrective actions have been implemented. The principles and objectives provided by the Code are applicable by all those responsible for the nuclear power plant, by plant designers, suppliers, architect-engineers, plant constructors, plant operators and other organizations participating in activities affecting quality. The Code is a revision of the previous Code of Practice (1978) on the same subject of interest to regulatory bodies and experts in quality assurance for design, siting and operation of nuclear power plants. Contents: Definitions; 1. Introduction; 2. Quality assurance programmes; 3. Organization; 4. Document control; 5. Design control; 6. Procurement control; 7. Control of items; 8. Process control; 9. Inspection and test control; 10. Non-conformance control; 11. Corrective actions; 12, Records; 13. Audits

  19. Near-facility environmental monitoring quality assurance project plan

    International Nuclear Information System (INIS)

    McKinney, S.M.

    1997-01-01

    This Quality Assurance Project Plan addresses the quality assurance requirements for the activities associated with the preoperational and near facility environmental monitoring performed by Waste Management Federal Services, Inc., Northwest Operations and supersedes WHC-EP-0538-2. This plan applies to all sampling and monitoring activities performed by waste management Federal Services, Inc., Northwest Operations in implementing facility environmental monitoring at the Hanford Site

  20. Quality Assurance in Custom Dental Devices: A Technologist's Perspective.

    Science.gov (United States)

    Griffin, Anthony

    2017-12-01

    Manufacturing of custom-made dental devices such as removable dentures, fixed prosthodontics and orthodontics are subject to the requirements of the Medical Devices Directive (MDD). Many dental laboratories often enhance these requirements by implementing quality assurance procedures that then provide enhanced consistency. this paper provides a dental technologist's view of some of the systems currently being used in dental laboratories to provide a quality assured product and associated issues.