  1. Evaluation of Grounding Impedance of a Complex Lightning Protective System Using Earth Ground Clamp Measurements and ATP Modeling

    Science.gov (United States)

    Mata, Carlos T.; Rakov, V. A.; Mata, Angel G.

    2010-01-01

    A new Lightning Protection System (LPS) was designed and built at Launch Complex 39B (LC39B), at the Kennedy Space Center (KSC), Florida, which consists of a catenary wire system (at a height of about 181 meters above ground level) supported by three insulators installed atop three towers in a triangular configuration. A total of nine downconductors (each about 250 meters long, on average) are connected to the catenary wire system. Each of the nine downconductors is connected to a 7.62-meter radius circular counterpoise conductor with six equally spaced 6-meter long vertical grounding rods. Grounding requirements at LC39B call for all underground and above ground metallic piping, enclosures, raceways, and cable trays, within 7.62 meters of the counterpoise, to be bounded to the counterpoise, which results in a complex interconnected grounding system, given the many metallic piping, raceways, and cable trays that run in multiple direction around LC39B. The complexity of this grounding system makes the fall of potential method, which uses multiple metallic rods or stakes, unsuitable for measuring the grounding impedances of the downconductors. To calculate the downconductors grounding impedance, an Earth Ground Clamp (a stakeless grounding resistance measuring device) and a LPS Alternative Transient Program (ATP) model are used. The Earth Ground Clamp is used to measure the loop impedance plus the grounding impedance of each downconductor and the ATP model is used to calculate the loop impedance of each downconductor circuit. The grounding impedance of the downconductors is then calculated by subtracting the ATP calculated loop impedances from the Earth Ground Clamp measurements.

  2. Outdoor ground impedance models.

    Science.gov (United States)

    Attenborough, Keith; Bashir, Imran; Taherzadeh, Shahram

    2011-05-01

    Many models for the acoustical properties of rigid-porous media require knowledge of parameter values that are not available for outdoor ground surfaces. The relationship used between tortuosity and porosity for stacked spheres results in five characteristic impedance models that require not more than two adjustable parameters. These models and hard-backed-layer versions are considered further through numerical fitting of 42 short range level difference spectra measured over various ground surfaces. For all but eight sites, slit-pore, phenomenological and variable porosity models yield lower fitting errors than those given by the widely used one-parameter semi-empirical model. Data for 12 of 26 grassland sites and for three beech wood sites are fitted better by hard-backed-layer models. Parameter values obtained by fitting slit-pore and phenomenological models to data for relatively low flow resistivity grounds, such as forest floors, porous asphalt, and gravel, are consistent with values that have been obtained non-acoustically. Three impedance models yield reasonable fits to a narrow band excess attenuation spectrum measured at short range over railway ballast but, if extended reaction is taken into account, the hard-backed-layer version of the slit-pore model gives the most reasonable parameter values.

  3. Acoustic Ground-Impedance Meter

    Science.gov (United States)

    Zuckerwar, A. J.

    1983-01-01

    Helmoltz resonator used in compact, portable meter measures acoustic impedance of ground or other surfaces. Earth's surface is subject of increasing acoustical investigations because of its importance in aircraft noise prediction and measurment. Meter offers several advantages. Is compact and portable and set up at any test site, irrespective of landscape features, weather or other environmental condition.

  4. Acoustic ground impedance meter

    Science.gov (United States)

    Zuckerwar, A. J. (Inventor)

    1984-01-01

    A method and apparatus are presented for measuring the acoustic impedance of a surface in which the surface is used to enclose one end of the chamber of a Helmholz resonator. Acoustic waves are generated in the neck of the resonator by a piston driven by a variable speed motor through a cam assembly. The acoustic waves are measured in the chamber and the frequency of the generated acoustic waves is measured by an optical device. These measurements are used to compute the compliance and conductance of the chamber and surface combined. The same procedure is followed with a calibration plate having infinite acoustic impedance enclosing the chamber of the resonator to compute the compliance and conductance of the chamber alone. Then by subtracting, the compliance and conductance for the surface is obtained.

  5. Impact of SSSC on Measured Impedance in Single Phase to Ground Fault Condition on 220 kV Transmission Line

    Directory of Open Access Journals (Sweden)

    Mohamed ZELLAGUI

    2012-08-01

    Full Text Available This paper presents and compares the impact of SSSC on measured impedance for single phase to ground fault condition. The presence of Static Synchronous SSSC on a transmission line has a great influence on the ZRelay in distance protection. The protection of the high voltage 220 kV single circuit transmission line in eastern Algerian electrical transmission networks is affected in the case with resistance fault RF. The paper investigate the effect of Static Synchronous Series Compensator (SSSC on the measured impedance (Relay taking into account the distance fault point (n and fault resistance (RF. The resultants simulation is performed in MATLAB software environment.

  6. Microwave Impedance Measurement for Nanoelectronics

    Directory of Open Access Journals (Sweden)

    M. Randus

    2011-04-01

    Full Text Available The rapid progress in nanoelectronics showed an urgent need for microwave measurement of impedances extremely different from the 50Ω reference impedance of measurement instruments. In commonly used methods input impedance or admittance of a device under test (DUT is derived from measured value of its reflection coefficient causing serious accuracy problems for very high and very low impedances due to insufficient sensitivity of the reflection coefficient to impedance of the DUT. This paper brings theoretical description and experimental verification of a method developed especially for measurement of extreme impedances. The method can significantly improve measurement sensitivity and reduce errors caused by the VNA. It is based on subtraction (or addition of a reference reflection coefficient and the reflection coefficient of the DUT by a passive network, amplifying the resulting signal by an amplifier and measuring the amplified signal as a transmission coefficient by a common vector network analyzer (VNA. A suitable calibration technique is also presented.

  7. Short-circuit impedance measurement

    DEFF Research Database (Denmark)

    Pedersen, Knud Ole Helgesen; Nielsen, Arne Hejde; Poulsen, Niels Kjølstad

    2003-01-01

    Methods for estimating the short-circuit impedance in the power grid are investigated for various voltage levels and situations. The short-circuit impedance is measured, preferably from naturally occurring load changes in the grid, and it is shown that such a measurement system faces different...

  8. Acoustic impedances of ear canals measured by impedance tube

    DEFF Research Database (Denmark)

    Ciric, Dejan; Hammershøi, Dorte

    2007-01-01

    During hearing sensitivity tests, the sound field is commonly generated by an earphone placed on a subject ear. One of the factors that can affect the sound transmission in the ear is the acoustic impedance of the ear canal. Its importance is related to the contribution of other elements involved...... in the transmission such as the earphone impedance. In order to determine the acoustic impedances of human ear canals, the standardized method for measurement of complex impedances used for the measurement of the audiometric earphone impedances is applied. It is based on the transfer function between two microphone...... locations in an impedance tube. The end of the tube representing the measurement plane is placed at the ear canal entrance. Thus, the impedance seen from the entrance inward is measured on 25 subjects. Most subjects participated in the previous measurement of the ratio between the pressures at the open...

  9. Ground Loop Impedance of Long EHV Cable Lines

    DEFF Research Database (Denmark)

    Ohno, Teruo; Bak, Claus Leth; Sørensen, Thomas K.

    2012-01-01

    The distance protection scheme without communication is often applied to the backup protection of EHV cable lines. For a reliable operation of a ground distance relay, the ground loop impedance of EHV cable lines needs to have a linear relationship to the distance from the relay location to the f...

  10. Characteristic Impedance of a Microstrip-Like Interconnect Line in Presence of Ground Plane Aperture

    Directory of Open Access Journals (Sweden)

    Rohit Sharma

    2007-01-01

    Full Text Available We propose new empirical expressions for the characteristic impedance of a microstrip-like interconnect line in presence of ground plane aperture. The existing characteristic impedance expressions are modified so as to include the effect of the ground plane aperture. The variation in the characteristic impedance vis-à-vis the aperture size is established. The proposed expressions are general and valid for a range of dielectric materials concerning MICs, RFICs, and PCBs. The results are validated by measurements performed on a vector network analyzer.

  11. Microfabricated Thin Film Impedance Sensor & AC Impedance Measurements

    Directory of Open Access Journals (Sweden)

    Jinsong Yu

    2010-06-01

    Full Text Available Thin film microfabrication technique was employed to fabricate a platinum based parallel-electrode structured impedance sensor. Electrochemical impedance spectroscopy (EIS and equivalent circuit analysis of the small amplitude (±5 mV AC impedance measurements (frequency range: 1 MHz to 0.1 Hz at ambient temperature were carried out. Testing media include 0.001 M, 0.01 M, 0.1 M NaCl and KCl solutions, and alumina (~3 μm and sand (~300 μm particulate layers saturated with NaCl solutions with the thicknesses ranging from 0.6 mm to 8 mm in a testing cell, and the results were used to assess the effect of the thickness of the particulate layer on the conductivity of the testing solution. The calculated resistances were approximately around 20 MΩ, 4 MΩ, and 0.5 MΩ for 0.001 M, 0.01 M, and 0.1 M NaCl solutions, respectively. The presence of the sand particulates increased the impedance dramatically (6 times and 3 times for 0.001 M and 0.1 M NaCl solutions, respectively. A cell constant methodology was also developed to assess the measurement of the bulk conductivity of the electrolyte solution. The cell constant ranged from 1.2 to 0.8 and it decreased with the increase of the solution thickness.

  12. Artificial impedance ground planes for low profile antenna applications

    Science.gov (United States)

    McMichael, Ian T.

    Recent interest in artificial impedance surfaces for low-profile antennas has led to extensive research with the goal of optimizing the ground plane's characteristics for a given antenna configuration and broadening the operational bandwidth, or alternatively creating a multi-band functionality. A method of determining the optimal reflection phase for a low-profile dipole antenna over an electromagnetic band gap (EBG) ground plane has been developed based on image theory and is presented with experimental and numerical validation. A new artificial impedance surface has also been developed, which is composed of an annular slot ring on a thin grounded dielectric. The main difference between the proposed ground plane and a conventional EBG is that the high impedance condition exists only in the vicinity of the slot and is therefore best suited for antennas with a current distribution that has a similar shape as the annular slot ring. It is shown that a loop antenna positioned closely over an annular slot loaded ground plane exhibits approximately the same gain as a loop antenna over a conventional EBG ground plane. The advantage of the new structure is its lack of periodicity, which significantly eases manufacturing. Additionally, it is shown that multiple concentric slot rings can be designed into the ground plane, which excites multiple resonances in low-profile wideband antennas. The result is a multi-band high impedance ground plane constructed using a simple arrangement of annular slots. Finally, a manufacturing technique is presented for the application of arbitrarily configured EBG antennas to handheld dual-sensor landmine detection systems. It is shown that creating an EBG antenna using very thin layers of metal will enable it to be used for ground penetrating radar (GPR) when it is co-located with a low frequency metal detector without compromising the operation of the metal detector. The potential benefit of such an antenna would be a lower profile sensor

  13. Impedance of Surface Footings on Layered Ground

    DEFF Research Database (Denmark)

    Andersen, Lars; Clausen, Johan Christian

    2005-01-01

    Traditionally only the static bearing capacity and stiffness of the ground is considered in the design of wind turbine foundations. However, modern wind turbines are flexible structures with resonance frequencies as low as 0.2 Hz. Unfortunately, environmental loads and the passage of blades past...... the tower may lead to excitation with frequencies of the same order of magnitude. Therefore, dynamic soil-structure interaction has to be accounted for in order to get an accurate prediction of the structural response. In this paper the particular problem of a rigid foundation on a layered subsoil...

  14. Impedance of Surface Footings on Layered Ground

    DEFF Research Database (Denmark)

    Andersen, Lars; Clausen, Johan

    2007-01-01

    Traditionally only the static bearing capacity and stiffness of the ground is considered in the design of wind turbine foundations. However, modern wind turbines are flexible structures with resonance frequencies as low as 0.2 Hz. Unfortunately, environmental loads and the passage of blades past...... the tower may lead to excitation with frequencies of the same order of magnitude. Therefore, dynamic soilstructure interaction has to be accounted for in order to get an accurate prediction of the structural response. In this paper the particular problem of a rigid foundation on a layered subsoil...

  15. Quantification of coating aging using impedance measurements

    NARCIS (Netherlands)

    Westing, E.P.M. van; Weijde, D.H. van der; Vreijling, M.P.W.; Ferrari, G.M.; Wit, J.H.W. de

    1998-01-01

    This chapter shows the application results of a novel approach to quantify the ageing of organic coatings using impedance measurements. The ageing quantification is based on the typical impedance behaviour of barrier coatings in immersion. This immersion behaviour is used to determine the limiting c

  16. Electrical Impedance Measurements of PZT Nanofiber Sensors

    Directory of Open Access Journals (Sweden)

    Richard Galos

    2017-01-01

    Full Text Available Electrical impedance measurements of PZT nanofiber sensors were performed using a variety of methods over a frequency spectrum ranging from DC to 1.8 GHz. The nanofibers formed by electrospinning with diameters ranging from 10 to 150 nm were collected and integrated into sensors using microfabrication techniques. Special matching circuits with ultrahigh input impedance were fabricated to produce low noise, measurable sensor outputs. Material properties including resistivity and dielectric constant are derived from the impedance measurements. The resulting material properties are also compared with those of individual nanofibers being tested using conductive AFM and Scanning Conductive Microscopy.

  17. Analysis of impedance measurements of a suspension of microcapsules using a variable length impedance measurement cell

    Directory of Open Access Journals (Sweden)

    Dejan Krizaj

    2012-10-01

    Full Text Available Electrical impedance measurements of the suspensions have to take into account the double layer impedance that is due to a very thin charged layer formed at the electrode-electrolite interface. A dedicated measuring cell that enables variation of the distance between the electrodes was developed for investigation of electrical properties of suspensions using two electrode impedance measurements. By varying the distance between the electrodes it is possible to separate the double layer and the suspension impedance from the measured data. From measured and extracted impedances electrical lumped models have been developed. The error of non inclusion of the double layer impedance has been analyzed. The error depends on the frequency of the measurements as well as on the distance between the electrodes.

  18. Breathing detection with a portable impedance measurement system: first measurements.

    Science.gov (United States)

    Cordes, Axel; Foussier, Jerome; Leonhardt, Steffen

    2009-01-01

    For monitoring the health status of individuals, detection of breathing and heart activity is important. From an electrical point of view, it is known that breathing and heart activity change the electrical impedance distribution in the human body over the time due to ventilation (high impedance) and blood shifts (low impedance). Thus, it is possible to detect both important vital parameters by measuring the impedance of the thorax or the region around lung and heart. For some measurement scenarios it is also essential to detect these parameters contactless. For instance, monitoring bus drivers health could help to limit accidents, but directly connected systems limit the drivers free moving space. One measurement technology for measuring the impedance changes in the chest without cables is the magnetic impedance tomography (MIT). This article describes a portable measurement system we developed for this scenario that allows to measure breathing contactless. Furthermore, first measurements with five volunteers were performed and analyzed.

  19. Bench Measurements of Low Frequency Transverse Impedance

    CERN Document Server

    Caspers, Friedhelm; Mostacci, A

    2003-01-01

    For frequencies below 10 MHz the classical two wire transmission line method is subject to difficulties in sensitivity and measurement uncertainties. Thus for evaluation of the low frequency transverse impedance properties of the LHC dump kicker a modified version of the two wire transmission line has been used. It consists, in the present case, of a 10 turn loop of approximately 1 meter length and 2 cm width. The change of input impedance of the loop is measured as a function of the surroundings and by using a proper reference (metallic beampipe) these changes are converted into a meaningful transverse beam coupling impedance. Measurements of several calibration objects have shown close agreement with theoretical results.

  20. Protein Aggregation Measurement through Electrical Impedance Spectroscopy

    Science.gov (United States)

    Affanni, A.; Corazza, A.; Esposito, G.; Fogolari, F.; Polano, M.

    2013-09-01

    The paper presents a novel methodology to measure the fibril formation in protein solutions. We designed a bench consisting of a sensor having interdigitated electrodes, a PDMS hermetic reservoir and an impedance meter automatically driven by calculator. The impedance data are interpolated with a lumped elements model and their change over time can provide information on the aggregation process. Encouraging results have been obtained by testing the methodology on K-casein, a protein of milk, with and without the addition of a drug inhibiting the aggregation. The amount of sample needed to perform this measurement is by far lower than the amount needed by fluorescence analysis.

  1. Measuring mechanical impedance in clayey gravelly soils

    Directory of Open Access Journals (Sweden)

    R. Stolf

    1998-06-01

    Full Text Available Mechanical impedance of clayey and gravelly soils is often needed to interpret experimental results from tillage and other field experiments. Its measurement is difficult with manual and hydraulic penetrometers, which often bend or break in such soils. The purpose of this study was to evaluate the feasibility of a hand-operated "Stolf" impact penetrometer to measure mechanical impedance (soil resistance. The research was conducted in Raleigh, North Carolina, USA (35º 45'N, 78º 42'W, elevation 75 m. Corn was planted on April 19, 1991. Penetrometer measurements were taken on May 10, 1991, in 5 cm intervals to 60 cm at 33 locations on a transect perpendicular to the corn rows in each of four tillage treatments. The data permitted three-dimensional displays showing how mechanical impedance changed with depth and distance along the transect. The impact penetrometer proved to be a useful tool to collect quantitative mechanical impedance data on "hard" clayey and/or gravelly soils which previously were difficult to reliably quantify.

  2. Algorithmic Error Correction of Impedance Measuring Sensors

    Science.gov (United States)

    Starostenko, Oleg; Alarcon-Aquino, Vicente; Hernandez, Wilmar; Sergiyenko, Oleg; Tyrsa, Vira

    2009-01-01

    This paper describes novel design concepts and some advanced techniques proposed for increasing the accuracy of low cost impedance measuring devices without reduction of operational speed. The proposed structural method for algorithmic error correction and iterating correction method provide linearization of transfer functions of the measuring sensor and signal conditioning converter, which contribute the principal additive and relative measurement errors. Some measuring systems have been implemented in order to estimate in practice the performance of the proposed methods. Particularly, a measuring system for analysis of C-V, G-V characteristics has been designed and constructed. It has been tested during technological process control of charge-coupled device CCD manufacturing. The obtained results are discussed in order to define a reasonable range of applied methods, their utility, and performance. PMID:22303177

  3. Algorithmic Error Correction of Impedance Measuring Sensors

    Directory of Open Access Journals (Sweden)

    Vira Tyrsa

    2009-12-01

    Full Text Available This paper describes novel design concepts and some advanced techniques proposed for increasing the accuracy of low cost impedance measuring devices without reduction of operational speed. The proposed structural method for algorithmic error correction and iterating correction method provide linearization of transfer functions of the measuring sensor and signal conditioning converter, which contribute the principal additive and relative measurement errors. Some measuring systems have been implemented in order to estimate in practice the performance of the proposed methods. Particularly, a measuring system for analysis of C-V, G-V characteristics has been designed and constructed. It has been tested during technological process control of charge-coupled device CCD manufacturing. The obtained results are discussed in order to define a reasonable range of applied methods, their utility, and performance.

  4. Ground effects of space weather investigated by the surface impedance

    Science.gov (United States)

    Pirjola, R.; Boteler, D.; Trichtchenko, L.

    2009-02-01

    The objective of this paper is to provide a discussion of the surface impedance applicable in connection with studies of geomagnetically induced currents (GIC) in technological systems. This viewpoint means that the surface impedance is regarded as a tool to determine the horizontal (geo)electric field at the Earth's surface, which is the key quantity for GIC. Thus the approach is different from the traditional magnetotelluric viewpoint. The definition of the surface impedance usually involves wavenumber-frequency-domain fields, so inverse Fourier transforming the expression of the electric field in terms of the surface impedance and the geomagnetic field results in convolution integrals in the time and space domains. The frequency-dependent surface impedance has a high-pass filter character whereas the corresponding transfer function between the electric field and the time derivative of the magnetic field is of a low-pass filter type. The relative change of the latter transfer function with frequency is usually smaller than that of the surface impedance, which indicates that the geoelectric field is closer to the time derivative than to the magnetic field itself. An investigation of the surface impedance defined by the space-domain electric and magnetic components indicates that the largest electric fields are not always achieved by the plane wave assumption, which is sometimes regarded as an extreme case for GIC. It is also concluded in this paper that it is often possible to apply the plane wave relation locally between the surface electric and magnetic fields. The absolute value of the surface impedance decreases with an increasing wavenumber although the maximum may also be at a non-zero value of the wavenumber. The imaginary part of the surface impedance usually much exceeds the real part.

  5. Generalised Impedance Converters with only Transconductance Elements and Grounded Capacitors

    Directory of Open Access Journals (Sweden)

    Iqbal A. Khan

    2002-01-01

    capacitors in the realisation of continuous time filters lend to electronic tunability and compatibility to integration in contemporary IC technologies. The generalised impedance converters are also verified using PSPICE-based simulation.

  6. A review of impedance measurements of whole cells.

    Science.gov (United States)

    Xu, Youchun; Xie, Xinwu; Duan, Yong; Wang, Lei; Cheng, Zhen; Cheng, Jing

    2016-03-15

    Impedance measurement of live biological cells is widely accepted as a label free, non-invasive and quantitative analytical method to assess cell status. This method is easy-to-use and flexible for device design and fabrication. In this review, three typical techniques for impedance measurement, i.e., electric cell-substrate impedance sensing, Impedance flow cytometry and electric impedance spectroscopy, are reviewed from the aspects of theory, to electrode design and fabrication, and applications. Benefiting from the integration of microelectronic and microfluidic techniques, impedance sensing methods have expanded their applications to nearly all aspects of biology, including living cell counting and analysis, cell biology research, cancer research, drug screening, and food and environmental safety monitoring. The integration with other techniques, the fabrication of devices for certain biological assays, and the development of point-of-need diagnosis devices is predicted to be future trend for impedance sensing techniques. Copyright © 2015 Elsevier B.V. All rights reserved.

  7. Impedance Localization Measurements using AC Dipoles in the LHC

    CERN Document Server

    Biancacci, Nicolo; Papotti, Giulia; Persson, Tobias; Salvant, Benoit; Tomás, Rogelio

    2016-01-01

    The knowledge of the LHC impedance is of primary importance to predict the machine performance and allow for the HL-LHC upgrade. The developed impedance model can be benchmarked with beam measurements in order to assess its validity and limit. This is routinely done, for example, moving the LHC collimator jaws and measuring the induced tune shift. In order to localize possible unknown impedance sources, the variation of phase advance with intensity between beam position monitors can be measured. In this work we will present the impedance localization measurements performed at injection in the LHC using AC dipoles as exciter as well as the underlying theory.

  8. Thorax mapping for localised lung impedance change using focused impedance measurement (FIM: A pilot study

    Directory of Open Access Journals (Sweden)

    Humayra Ferdous

    2013-12-01

    Full Text Available Focused Impedance Measurement (FIM is a technique where impedance can be measured with the optimum level of localization without much increase in complexity of measuring instrument. The electrodes are applied on the skin surface but the organs inside also contributes to the measurement, as the body is a volume conductor. In a healthy and disease free lung region, the air enters at breathe-in increases the impedance of the lung and impedance reduces during breathe-out. In contrast, for a diseased lung, where part of the lungs is filled with water or some fluid, air will not enter into this zone reducing impedance change between inspiration and expiration. With this idea, the current work had been executed to have general view of localised impedance change throughout thorax using 6-electrode FIM. This generated a matrix mapping from both the front and from the back of the thorax, which  afterwards provided that how impedance change due to ventilation varies from frontal plane to back plane of human bodies.

  9. Will Arctic ground squirrels impede or accelerate climate-induced vegetation changes to the Arctic tundra?

    Science.gov (United States)

    Dalton, J.; Flower, C. E.; Brown, J.; Gonzalez-Meler, M. A.; Whelan, C.

    2014-12-01

    Considerable attention has been given to the climate feedbacks associated with predicted vegetation shifts in the Arctic tundra in response to global environmental change. However, little is known regarding the extent to which consumers can facilitate or respond to shrub expansion. Arctic ground squirrels, the largest and most northern ground squirrel, are abundant and widespread throughout the North American tundra. Their broad diet of seeds, flowers, herbage, bird's eggs and meat speaks to the need to breed, feed, and fatten in a span of some 12-16 weeks that separate their 8-9 month bouts of hibernation with the potential consequence to impact ecosystem dynamics. Therefore Arctic ground squirrels are a good candidate to evaluate whether consumers are mere responders (bottom-up effects) or drivers (top-down) of the observed and predicted vegetation changes. As a start towards this question, we measured the foraging intensity (giving-up densities) of Arctic ground squirrels in experimental food patches within which the squirrels experience diminishing returns as they seek the raisins and peanuts that we provided at the Toolik Lake field station in northern Alaska. If the squirrels show their highest feeding intensity in the shrubs, they may impede vegetation shifts by slowing the establishment and expansion of shrubs in the tundra. Conversely, if they show their lowest feeding intensity within shrub dominated areas, they may accelerate vegetation shifts. We found neither. Feeding intensity varied most among transects and times of day, and least along a tundra-to-shrub vegetation gradient. This suggests that the impacts of squirrels will be heterogeneous - in places responders and in others drivers. We should not be surprised then to see patches of accelerated and impeded vegetation changes in the tundra ecosystem. Some of these patterns may be predictable from the foraging behavior of Arctic ground squirrels.

  10. Beam measurements of the LHC impedance and validation of the impedance model

    CERN Document Server

    Esteban Müller, J F; Bohl, T; Mounet, N; Shaposhnikova, E; Timko, H

    2014-01-01

    Different measurements of the longitudinal impedance of the LHC done with single bunches with various intensities and longitudinal emittances during measurement sessions in 2011-2012 are compared with particle simulations based on the existing LHC impedance model. The very low reactive impedance of the LHC, with Im Z=n = 0.08, is not easy to measure. The most sensitive observation is the loss of Landau damping, which shows at which energy bunches become unstable depending on their parameters. In addition, the synchrotron frequency shift due to the reactive impedance was estimated following two methods. Firstly, it was obtained from the peak-detected Schottky spectrum. Secondly, a sine modulation in the RF phase was applied to the bunches of different intensities and the modulation frequency was scanned. In both cases, the synchrotron frequency shift was of the order of the measurement precision.

  11. Transverse impedance measurement in RHIC and the AGS

    Energy Technology Data Exchange (ETDEWEB)

    Biancacci, Nicolo [European Organization for Nuclear Research (CERN), Geneva (Switzerland); Blaskiewicz, M. [Brookhaven National Lab. (BNL), Upton, NY (United States). Collider-Accelerator Dept.; Dutheil, Y. [Brookhaven National Lab. (BNL), Upton, NY (United States). Collider-Accelerator Dept.; Liu, C. [Brookhaven National Lab. (BNL), Upton, NY (United States). Collider-Accelerator Dept.; Mernick, M. [Brookhaven National Lab. (BNL), Upton, NY (United States). Collider-Accelerator Dept.; Minty, M. [Brookhaven National Lab. (BNL), Upton, NY (United States). Collider-Accelerator Dept.; White, S. M. [Brookhaven National Lab. (BNL), Upton, NY (United States). Collider-Accelerator Dept.

    2014-05-12

    The RHIC luminosity upgrade program aims for an increase of the polarized proton luminosity by a factor 2. To achieve this goal a significant increase in the beam intensity is foreseen. The beam coupling impedance could therefore represent a source of detrimental effects for beam quality and stability at high bunch intensities. For this reason it is essential to quantify the accelerator impedance budget and the major impedance sources, and possibly cure them. In this MD note we summarize the results of the 2013 transverse impedance measurements in the AGS and RHIC. The studies have been performed measuring the tune shift as a function of bunch intensity and deriving the total accelerator machine transverse impedance. For RHIC, we could obtain first promising results of impedance localization measurements as well.

  12. Longitudinal Impedance Measurements of the Components for the BEPCII

    CERN Document Server

    Zhou, Demin; Kang, Wen; Wang Jiu Qing; Zhou, Lijuan

    2005-01-01

    A longitudinal impedance measurement system was established for the BEPCII. The measurements, done in the frequency domain, are based on the coaxial wire method using HP/Agilent 8720ES network analyzer. The applications of the TRL calibration technique and absorbers were investigated to find a good approach for impedance measurements. The impedance, larger than 20 Ohm and below 6 GHz, can be measured using the TRL calibration technique in the experiment. And better measurement results were got using the reference pipes with the absorbers. So, this system satisfies the requirements of the BEPCII. This paper gives a review on this impedance measurements system for the BEPCII. The measurements results show that there are no serious impedance problems for BEPCII bellows and injection kickers, agreeing well with the numerical simulations. More improvements on this system are in progress.

  13. Plasma Diagnostics by Antenna Impedance Measurements

    Science.gov (United States)

    Swenson, C. M.; Baker, K. D.; Pound, E.; Jensen, M. D.

    1993-01-01

    The impedance of an electrically short antenna immersed in a plasma provides an excellent in situ diagnostic tool for electron density and other plasma parameters. By electrically short we mean that the wavelength of the free-space electromagnetic wave that would be excited at the driving frequency is much longer than the physical size of the antenna. Probes using this impedance technique have had a long history with sounding rockets and satellites, stretching back to the early 1960s. This active technique could provide information on composition and temperature of plasmas for comet or planetary missions. Advantages of the impedance probe technique are discussed and two classes of instruments built and flown by SDL-USU for determining electron density (the capacitance and plasma frequency probes) are described.

  14. Dynamic electrochemical impedance spectroscopy reconstructed from continuous impedance measurement of single frequency during charging/discharging

    Science.gov (United States)

    Huang, Jun; Li, Zhe; Zhang, Jianbo

    2015-01-01

    In this study, a novel implementation of dynamic electrochemical impedance spectroscopy (DEIS) is proposed. The method first measures the impedance continuously at a single frequency during one charging/discharging cycle, then repeats the measurement at a number of other selected frequencies. The impedance spectrum at a specific SOC is obtained by interpolating and collecting the impedance at all of the selected frequencies. The charge transfer resistance, Rct, from the DEIS is smaller than that from the steady EIS in a wide state-of-charge (SOC) range from 0.4 to 1.0, the Rct during charging is generally smaller than that during discharging for the battery chemistry used in this study.

  15. Measurements of Impedance and Attenuation at CENELEC Bands for Power Line Communications Systems

    Directory of Open Access Journals (Sweden)

    I. Hakki Cavdar

    2008-12-01

    Full Text Available Power line impedance is a very important parameter on the design of power line communications (PLC modem architecture. Variations on the impedance of the power line affect the communications circuit performance. In order to determine impedance of the power lines, measurements were carried out in Turkey at frequencies ranging from 10 to 170 kHz, (CENELEC A,B,C,D bands. Measurements were conducted in three categories: rural, urban and the industrial power lines. Experimental results are presented in graphical form. The measured impedances were determined as 3-17 ohms, 1-17 ohms, and 1-21 ohms for rural, urban and the industrial lines, respectively. A set of the formulas between impedance and frequency are developed on the power lines using the regression analysis from the obtained empirical data. Signal attenuations on the power lines in the CENELEC band are also measured for rural, urban and industrial regions. Attenuation measurements are repeated for phase-neutral, phase-ground and the neutral-ground conductors. Signal attenuations are found to be 4-30 dB, for different power lines. To establish validity of obtained results for the design of PLC systems, the results are compared with previous investigations. The effects of some household appliances such as TV, PC, UPS, lighting and cooling systems on the impedances and the attenuations for power line communications systems are observed. Some suggestions and proposals are presented for PLC modem designers.

  16. Effect of Feeding and Suction on Gastric Impedance Spectroscopy Measurements.

    Science.gov (United States)

    Beltran, Nohra E; Sánchez-Miranda, Gustavo; Sacristan, Emilio

    2015-01-01

    A specific device and system has been developed and tested for clinical monitoring of gastric mucosal reactance in the critically ill as an early warning of splanchnic hypoperfusion associated with shock and sepsis. This device has been proven effective in clinical trials and is expected to become commercially available next year. The system uses a combination nasogastric tube and impedance spectroscopy probe as a single catheter. Because this device has a double function, the question is: Does enteral feeding or suction affect the gastric reactance measurements? This study was designed to evaluate the effect of feeding and suction on the measurement of gastric impedance spectroscopy in healthy volunteers. Impedance spectra were obtained from the gastric wall epithelia of 18 subjects. The spectra were measured for each of the following conditions: postinsertion of gastric probe, during active suction, postactive suction, and during enteral feeding (236 ml of nutritional supplement). Impedance spectra were reproducible in all volunteers under all conditions tested. There was a slight increase in impedance parameters after suction, and a decrease in impedance after feeding; however, these observed differences were insignificant compared to patient-to-patient variability, and truly negligible compared with previously observed changes associated with splanchnic ischemia in critically ill patients. Our results demonstrate that suction or feeding when using the impedance spectro-metry probe/nasogastric tube does not significantly interfere with gastric impedance spectrometer measurements.

  17. Damage detection technique by measuring laser-based mechanical impedance

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Hyeonseok; Sohn, Hoon [Department of Civil and Environmental Engineering, Korea Advanced Institute of Science and Technology (Daehak-ro 291, Yuseong-gu, Daejeon 305-701) (Korea, Republic of)

    2014-02-18

    This study proposes a method for measurement of mechanical impedance using noncontact laser ultrasound. The measurement of mechanical impedance has been of great interest in nondestructive testing (NDT) or structural health monitoring (SHM) since mechanical impedance is sensitive even to small-sized structural defects. Conventional impedance measurements, however, have been based on electromechanical impedance (EMI) using contact-type piezoelectric transducers, which show deteriorated performances induced by the effects of a) Curie temperature limitations, b) electromagnetic interference (EMI), c) bonding layers and etc. This study aims to tackle the limitations of conventional EMI measurement by utilizing laser-based mechanical impedance (LMI) measurement. The LMI response, which is equivalent to a steady-state ultrasound response, is generated by shooting the pulse laser beam to the target structure, and is acquired by measuring the out-of-plane velocity using a laser vibrometer. The formation of the LMI response is observed through the thermo-mechanical finite element analysis. The feasibility of applying the LMI technique for damage detection is experimentally verified using a pipe specimen under high temperature environment.

  18. Microfluidic device for cell capture and impedance measurement.

    Science.gov (United States)

    Jang, Ling-Sheng; Wang, Min-How

    2007-10-01

    This work presents a microfluidic device to capture physically single cells within microstructures inside a channel and to measure the impedance of a single HeLa cell (human cervical epithelioid carcinoma) using impedance spectroscopy. The device includes a glass substrate with electrodes and a PDMS channel with micro pillars. The commercial software CFD-ACE+ is used to study the flow of the microstructures in the channel. According to simulation results, the probability of cell capture by three micro pillars is about 10%. An equivalent circuit model of the device is established and fits closely to the experimental results. The circuit can be modeled electrically as cell impedance in parallel with dielectric capacitance and in series with a pair of electrode resistors. The system is operated at low frequency between 1 and 100 kHz. In this study, experiments show that the HeLa cell is successfully captured by the micro pillars and its impedance is measured by impedance spectroscopy. The magnitude of the HeLa cell impedance declines at all operation voltages with frequency because the HeLa cell is capacitive. Additionally, increasing the operation voltage reduces the magnitude of the HeLa cell because a strong electric field may promote the exchange of ions between the cytoplasm and the isotonic solution. Below an operating voltage of 0.9 V, the system impedance response is characteristic of a parallel circuit at under 30 kHz and of a series circuit at between 30 and 100 kHz. The phase of the HeLa cell impedance is characteristic of a series circuit when the operation voltage exceeds 0.8 V because the cell impedance becomes significant.

  19. Measurement of Phase Dependent Impedance for 3-phase Diode Rectifier

    DEFF Research Database (Denmark)

    Kwon, Jun Bum; Wang, Xiongfei; Bak, Claus Leth

    2016-01-01

    This paper presents a new method to measure the phase dependent impedance from an experimental set up. Though most of power electronics based system is gradually migrating to IGBT based voltage source converter due to their controllability, the rectifier composed of diode or thyristor components...... are still widely used in AC-DC applications because of their cost effectiveness and reliability. However, these topologies generate harmonic problems in their network due to their switching instant variation caused by the frequency and phase of grid voltage. Hence, a lot of solutions have been proposed...... application. It is found that the phase dependent impedance shows different properties with the impedance profiles, which have been proposed in the research. This paper explains a method to measure the phase dependent impedance profile from an experimental set up. Furthermore, the results are compared...

  20. Smart mug to measure hand's geometrical mechanical impedance.

    Science.gov (United States)

    Hondori, Hossein Mousavi; Tech, Ang Wei

    2011-01-01

    A novel device, which looks like a mug, has been proposed for measuring the impedance of human hand. The device is designed to have convenient size and light weight similar to an ordinary coffee mug. It contains a 2-axis inertia sensor to monitor vibration and a small motor to carry an eccentric mass (m=100 gr, r=2 cm, rpm=600). The centrifugal force due to the rotating mass applies a dynamic force to the hand that holds the mug. Correlation of the acceleration signals with the perturbing force gives the geometrical mechanical impedance. Experimental results on a healthy subject shows that impedance is posture dependant while it changes with the direction of the applied perturbing force. For nine postures the geometrical impedance is obtained all of which have elliptical shapes. The method can be used for assessment of spasticity and monitoring stability in patients with stroke or similar problems.

  1. Intrathoracic electrical impedance measurements from an esophageal probe.

    Science.gov (United States)

    Mitchell, M M; Newbower, R S

    1979-03-01

    The sensing of intrathoracic electrical impedance from an esophageal probe may allow relatively noninvasive monitoring of cardiac and respiratory functions of particular interest in anesthesia and intensive care. We have obtained a partial solution of the intrathoracic current-field problem for impedance measurements made from a four-terminal linear array of electrodes located in the esophagus. It allows prediction that aortic root motion will exceed aortic distension as a major determinant of the cardiac intrathoracic esophageal impedance signal. This prediction was confirmed for a specific carefully selected and placed electrode array in anesthetized dogs. In general, motions of organs will be more important than volume changes in affecting the esophageal impedance signal. Thus, timing information (preejection period and left ventricular ejection time) is available from electrodes on an esophageal probe, but cardiac output information appears to be inaccessible for fundamental reasons.

  2. Experimental verification of depolarization effects in bioelectrical impedance measurement.

    Science.gov (United States)

    Chen, Xiaoyan; Lv, Xinqiang; Du, Meng

    2014-01-01

    The electrode polarization effects on bioelectrical impedance measurement at low-frequency cannot be ignored. In this paper, the bioelectrical data of mice livers are measured to specify the polarization effects on the bio-impedance measurement data. We firstly introduce the measurement system and methodology. Using the depolarization method, the corrected results are obtained. Besides, the specific effects of electrode polarization on bio-impedance measurement results are investigated using comparative analysis of the previous and posterior correction results from dielectric spectroscopy, Cole-Cole plot, conductivity and spectroscopy of dissipation tangent. Experimental results show that electrode polarization has a significant influence on the characteristic parameters of mouse liver tissues. To be specific, we see a low-frequency limit resistance R0 increase by 19.29%, a reactance peak XP increase by 8.50%, a low-frequency limit conductivity Kl decrease by 17.65% and a dissipation peak tangent decrease by 160%.

  3. Measurement of solar cell parameters using impedance spectroscopy

    Energy Technology Data Exchange (ETDEWEB)

    Suresh, M.S. [Battery Division, ISRO Satellite Centre, Bangalore (India)

    1996-08-15

    Measurement of solar cell parameters is important for the design of satellite power systems. These parameters can be measured using impedance spectroscopy and an equivalent circuit model developed. In this study parameters of a Back Surface Reflector Field solar cell (BSFR) have been measured using impedance spectroscopy. The results show high diffusion capacitance of BSFR cells and their exponential relation to the operating voltage. Cell dynamic resistance, diode factor, transition capacitance, and series resistance could also be measured. The minority carrier life time also has been calculated

  4. The influence of urine volume on body impedance measurement.

    Science.gov (United States)

    Hong, K H; Park, K S

    2008-01-01

    Bio-signal has some characteristics that the signal is so weak. So, it is good that the factors to influence measured electrical signal are eliminated as much as they can. So, in this paper we will show the influence of urine in bladder on measuring human body impedance. Human urine has different conductivity from other human tissues. Therefore, if the volume of the urine changed, the measured body impedance data also changed.So, in this paper, we will show the influence of urine in bladder with foot-to-foot and thigh-to-thigh current paths. As a result, if the current flows through human bladder, the influence of urine in the bladder must be considered when the body impedance is measured

  5. Reliability of impedance cardiography in measuring central haemodynamics

    DEFF Research Database (Denmark)

    Mehlsen, J; Bonde, J; Stadeager, C

    1991-01-01

    than 0.001). We found a qualitative but no quantitative correlation between thoracic fluid volume measured by IC and central blood volume measured by isotope dilution. IC was highly reproducible both when studies were repeated within the same day (SD on differences in CO = 0.36 1 min-1 for IC; SD...... suitable for repeated measurements in studies on the haemodynamic effects of physiological or pharmacological intervention. Impedance cardiography is sufficiently reliable for comparison of absolute values of CO between different groups of patients. We cannot recommend impedance cardiography...... for quantitative studies of central blood volume....

  6. In situ impedance measurement of microwave atmospheric pressure plasma

    Science.gov (United States)

    Lee, S. T.; Nam, W. J.; Lee, J. K.; Yun, G. S.

    2017-04-01

    The impedance of atmospheric pressure argon plasma jets driven by microwave frequency is determined in situ by a novel ‘two frequency method’. In the conventional method of reflection coefficient ({{S}}11) measurement, the frequency of the driving microwave power is scanned, which inevitably affects the plasma characters and leads to uncertainty in the estimated plasma impedance. In our proposed method, the frequency-scanning signal additional to the driving power is used to measure {{S}}11 over a wide frequency range, which enables accurate determination of the plasma impedance based on an equivalent circuit model. The measured resistance and reactance of the plasma increase with the driving power in agreement with the transmission line theory. Based on this in situ measurement of the plasma impedance, the net power coupled to the plasma has been determined. The overall power efficiency remains approximately unchanged around 45% for different input power levels owing to the competing effects between the impedance mismatch and the volume change of the plasma.

  7. Impedance technique for measuring dielectrophoretic collection of microbiological particles

    CERN Document Server

    Allsopp, D W E; Brown, A P; Betts, W B

    1999-01-01

    Measurement of the impedance change resulting from the collection of microbiological particles at coplanar electrodes is shown to be an effective and potentially quantitative method of detecting dielectrophoresis. Strong correlations between the frequency-dependent dielectrophoretic collection characteristics measured by impedance change and those observed using an established counting method based on image analysis have been obtained for Escherichia coli. In addition it is shown that the new electrical method can be used to sense dielectrophoretic collection of 19 nm diameter latex beads, particles too small to be resolved by conventional optical detection systems. (author)

  8. Signal Processing for the Impedance Measurement on an Electrochemical Generator

    Directory of Open Access Journals (Sweden)

    El-Hassane AGLZIM

    2008-04-01

    Full Text Available Improving the life time of batteries or fuel cells requires the optimization of components such as membranes and electrodes and enhancement of the flow of gases [1], [2]. These goals could be reached by using a real time measurement on loaded generator. The impedance spectroscopy is a new way that was recently investigated. In this paper, we present an electronic measurement instrumentation developed in our laboratory to measure and plot the impedance of a loaded electrochemical generator like batteries and fuel cells. Impedance measures were done according to variations of the frequency in a larger band than what is usually used. The electronic instrumentation is controlled by Hpvee® software which allows us to plot the Nyquist graph of the electrochemical generator impedance. The theoretical results obtained in simulation under Pspice® confirm the choice of the method and its advantage. For safety reasons, the experimental preliminary tests were done on a 12 V vehicle battery, having an input current of 330 A and a capacity of 40 Ah and are now extended to a fuel cell. The results were plotted at various nominal voltages of the battery (12.7 V, 10 V, 8 V and 5 V and with two imposed currents (0.6 A and 4 A. The Nyquist diagram resulting from the experimental data enable us to show an influence of the load of the battery on its internal impedance. The similitude in the graph form and in order of magnitude of the values obtained (both theoretical and practical enables us to validate our electronic measurement instrumentation. Different sensors (temperature, pressure were placed around the device under test (DUT. These influence parameters were permanently recorded. Results presented here concern a classic loaded 12 V vehicle battery. The Nyquist diagram resulting from the experimental data confirms the influence of the load of the DUT on its internal impedance.

  9. Construction and Testing of Broadband High Impedance Ground Planes (HIGPS) for Surface Mount Antennas

    Science.gov (United States)

    2008-03-01

    mushrooms (with side lengths of 7.6mm). Larger mushrooms (with side lengths of 16mm) were located to the edges of the substrate . The resulting...thickness and substrate permittivity are two of the main design parameters. But these parameters have production constraints, since they are ordered off...plane designs as a meta- substrate for a broadband bow-tie antenna were presented. Consequently, the high impedance ground plane provided a suitable

  10. Impedance Measurements on the LHC Dump Kicker Prototype

    CERN Document Server

    González, C; Dyachkov, M

    1998-01-01

    In this paper we demonstrate that a thin layer of metallization on the inner surface of the ceramic pipe in an abort kicker will provide an effective way to screen the kicker's magnets from the electr omagnetic fields generated by the LHC bunches. The other objective of this paper was to measure the kicker impedance in a wide frequency range (up to 1 GHz).

  11. Sensorless battery temperature measurements based on electrochemical impedance spectroscopy

    Science.gov (United States)

    Raijmakers, L. H. J.; Danilov, D. L.; van Lammeren, J. P. M.; Lammers, M. J. G.; Notten, P. H. L.

    2014-02-01

    A new method is proposed to measure the internal temperature of (Li-ion) batteries. Based on electrochemical impedance spectroscopy measurements, an intercept frequency (f0) can be determined which is exclusively related to the internal battery temperature. The intercept frequency is defined as the frequency at which the imaginary part of the impedance is zero (Zim = 0), i.e. where the phase shift between the battery current and voltage is absent. The advantage of the proposed method is twofold: (i) no hardware temperature sensors are required anymore to monitor the battery temperature and (ii) the method does not suffer from heat transfer delays. Mathematical analysis of the equivalent electrical-circuit, representing the battery performance, confirms that the intercept frequency decreases with rising temperatures. Impedance measurements on rechargeable Li-ion cells of various chemistries were conducted to verify the proposed method. These experiments reveal that the intercept frequency is clearly dependent on the temperature and does not depend on State-of-Charge (SoC) and aging. These impedance-based sensorless temperature measurements are therefore simple and convenient for application in a wide range of stationary, mobile and high-power devices, such as hybrid- and full electric vehicles.

  12. Using Impedance Measurements to Characterize Surface Modified with Gold Nanoparticles

    Science.gov (United States)

    MacKay, Scott; Abdelrasoul, Gaser N.; Tamura, Marcus; Yan, Zhimin

    2017-01-01

    With the increased practice of preventative healthcare to help reduce costs worldwide, sensor technology improvement is vital to patient care. Point-of-care (POC) diagnostics can reduce time and lower labor in testing, and can effectively avoid transporting costs because of portable designs. Label-free detection allows for greater versatility in the detection of biological molecules. Here, we describe the use of an impedance-based POC biosensor that can detect changes in the surface modification of a micro-fabricated chip using impedance spectroscopy. Gold nanoparticles (GNPs) have been employed to evaluate the sensing ability of our new chip using impedance measurements. Furthermore, we used impedance measurements to monitor surface functionalization progress on the sensor’s interdigitated electrodes (IDEs). Electrodes made from aluminum and gold were employed and the results were analyzed to compare the impact of electrode material. GNPs coated with mercaptoundecanoic acid were also used as a model of biomolecules to greatly enhance chemical affinity to the silicon substrate. The portable sensor can be used as an alternative technology to ELISA (enzyme-linked immunosorbent assays) and polymerase chain reaction (PCR)-based techniques. This system has advantages over PCR and ELISA both in the amount of time required for testing and the ease of use of our sensor. With other techniques, larger, expensive equipment must be utilized in a lab environment, and procedures have to be carried out by trained professionals. The simplicity of our sensor system can lead to an automated and portable sensing system.

  13. Recursive impedance inversion of ground-penetrating radar data in stochastic media

    Science.gov (United States)

    Zeng, Zhao-Fa; Chen, Xiong; Li, Jing; Chen, Ling-Na; Lu, Qi; Liu, Feng-Shan

    2015-12-01

    The travel time and amplitude of ground-penetrating radar (GPR) waves are closely related to medium parameters such as water content, porosity, and dielectric permittivity. However, conventional estimation methods, which are mostly based on wave velocity, are not suitable for real complex media because of limited resolution. Impedance inversion uses the reflection coefficient of radar waves to directly calculate GPR impedance and other parameters of subsurface media. We construct a 3D multiscale stochastic medium model and use the mixed Gaussian and exponential autocorrelation function to describe the distribution of parameters in real subsurface media. We introduce an elliptical Gaussian function to describe local random anomalies. The tapering function is also introduced to reduce calculation errors caused by the numerical simulation of discrete grids. We derive the impedance inversion workflow and test the calculation precision in complex media. Finally, we use impedance inversion to process GPR field data in a polluted site in Mongolia. The inversion results were constrained using borehole data and validated by resistivity data.

  14. Measurements of electrical impedance and elastic wave velocity of reservoir rock under fluid-flow test

    Science.gov (United States)

    Sawayama, Kazuki; Kitamura, Keigo; Fujimitsu, Yasuhiro

    2017-04-01

    The estimation of water saturation under the ground is essential in geothermal fields, particularly for EGS (enhanced geothermal system). To estimate water saturation, recently, electromagnetic exploration using Magnetotelluric (MT) method has been applied in the geothermal fields. However, the relationship between electrical impedance obtained from this method and water saturation in the reservoir rock has not been well known. Our goal is to elucidate this basic relationship by fluid-flow experiments. As our first step to this goal, we developed the technique to measure and analyze the electrical impedance of the cracked rock in the geothermal reservoir. The fluid-flow test has been conducted as following procedures. At first, reservoir rock sample (pyroxene andesite, Makizono lava formation, Japan) was filled with nitrogen gas (Pp = 10 MPa) under 20 MPa of confining pressure. This nitrogen gas imitates the overheated steam in the geothermal fields. Then, brine (1wt.%-KCl, 1.75 S/m) which imitates the artificial recharge to the reservoir was injected to the samples. After flow rate of drainage fluid becomes stable, injection pressure was increased (11, 12, 14, 16, 18 MPa) and decreased (18, 16, 14, 12, 11 MPa) to vary the water saturation in the samples. During the test, water saturation, permeability, electrical impedance (10-2-105 Hz of frequency) and elastic wave velocity were measured. As a result of andesite, electrical impedance dramatically decreased from 105 to 103 Ω and P-wave velocity increased by 2% due to the brine injection. This remarkable change of the electrical impedance could be due to the replacement of pre-filled nitrogen gas to the brine. After the brine injection, electrical impedance decreased with injection pressure (small change of water saturation) by up to 40% while P-wave velocity was almost constant (less than 1%). This decrease of electrical impedance with injection pressure could be related to the flow to the narrow path (microcrack

  15. Measurements of radar ground returns

    NARCIS (Netherlands)

    Loor, G.P. de

    1974-01-01

    The ground based measurement techniques for the determination of the radar back-scatter of vegetation and soils as used in The Netherlands will be described. Two techniques are employed: one covering a large sample area (> 1000 m2) but working at low grazing angels only and one (short range) coverin

  16. Contactless Impedance Sensors and Their Application to Flow Measurements

    Directory of Open Access Journals (Sweden)

    Karel Štulík

    2013-02-01

    Full Text Available The paper provides a critical discussion of the present state of the theory of high-frequency impedance sensors (now mostly called contactless impedance or conductivity sensors, the principal approaches employed in designing impedance flow-through cells and their operational parameters. In addition to characterization of traditional types of impedance sensors, the article is concerned with the use of less common sensors, such as cells with wire electrodes or planar cells. There is a detailed discussion of the effect of the individual operational parameters (width and shape of the electrodes, detection gap, frequency and amplitude of the input signal on the response of the detector. The most important problems to be resolved in coupling these devices with flow-through measurements in the liquid phase are also discussed. Examples are given of cell designs for continuous flow and flow-injection analyses and of detection systems for miniaturized liquid chromatography and capillary electrophoresis. New directions for the use of these sensors in molecular biology and chemical reactors and some directions for future development are outlined.

  17. Contactless impedance sensors and their application to flow measurements.

    Science.gov (United States)

    Opekar, František; Tůma, Petr; Stulík, Karel

    2013-02-27

    The paper provides a critical discussion of the present state of the theory of high-frequency impedance sensors (now mostly called contactless impedance or conductivity sensors), the principal approaches employed in designing impedance flow-through cells and their operational parameters. In addition to characterization of traditional types of impedance sensors, the article is concerned with the use of less common sensors, such as cells with wire electrodes or planar cells. There is a detailed discussion of the effect of the individual operational parameters (width and shape of the electrodes, detection gap, frequency and amplitude of the input signal) on the response of the detector. The most important problems to be resolved in coupling these devices with flow-through measurements in the liquid phase are also discussed. Examples are given of cell designs for continuous flow and flow-injection analyses and of detection systems for miniaturized liquid chromatography and capillary electrophoresis. New directions for the use of these sensors in molecular biology and chemical reactors and some directions for future development are outlined.

  18. Noninvasive measurement of transdermal drug delivery by impedance spectroscopy

    Science.gov (United States)

    Arpaia, Pasquale; Cesaro, Umberto; Moccaldi, Nicola

    2017-01-01

    The effectiveness in transdermal delivery of skin permeation strategies (e.g., chemical enhancers, vesicular carrier systems, sonophoresis, iontophoresis, and electroporation) is poorly investigated outside of laboratory. In therapeutic application, the lack of recognized techniques for measuring the actually-released drug affects the scientific concept itself of dosage for topically- and transdermally-delivered drugs. Here we prove the suitability of impedance measurement for assessing the amount of drug penetrated into the skin after transdermal delivery. In particular, the measured amount of drug depends linearly on the impedance magnitude variation normalized to the pre-treated value. Three experimental campaigns, based on the electrical analysis of the biological tissue behavior due to the drug delivery, are reported: (i) laboratory emulation on eggplants, (ii) ex-vivo tests on pig ears, and finally (iii) in-vivo tests on human volunteers. Results point out that the amount of delivered drug can be assessed by reasonable metrological performance through a unique measurement of the impedance magnitude at one single frequency. In particular, in-vivo results point out sensitivity of 23 ml−1, repeatability of 0.3%, non-linearity of 3.3%, and accuracy of 5.7%. Finally, the measurement resolution of 0.20 ml is compatible with clinical administration standards. PMID:28338008

  19. Probe impedance measurements for millimeter-wave integrated horn antennas

    Science.gov (United States)

    Guo, Yong; Chiao, Jung-Chih; Potter, Kent A.; Rutledge, David B.

    1993-01-01

    In order to achieve an impedance-matched millimeter-wave integrated horn antenna mixer array, the characteristics of the antenna probes inside the horn must be known. This paper describes impedance measurements for various probes in low-frequency model horns of two different types: (1) a 3 x 3 array made of aluminum by electric discharge machining and (2) a half horn made of copper sheet placed on a big copper-clad circuit board that was used as an image plane. The results of measurements indicate that the presence of the horn increases the effective length of the probe element, in agreement with reports of Guo et al. (1991) and theoretical analysis of Eleftheriades et al. (1991). It was also found that the resonant frequencies can be controlled by changing the length of the probes or by loading the probes.

  20. Determination of soil moisture distribution from impedance and gravimetric measurements

    Science.gov (United States)

    Ungar, Stephen G.; Layman, Robert; Campbell, Jeffrey E.; Walsh, John; Mckim, Harlan J.

    1992-01-01

    Daily measurements of the soil dielectric properties at 5 and 10 cm were obtained at five locations throughout the First ISLSCP Field Experiment (FIFE) test site during the 1987 intensive field campaigns (IFCs). An automated vector voltmeter was used to monitor the complex electrical impedance, at 10 MHz, of cylindrical volumes of soil delineated by specially designed soil moisture probes buried at these locations. The objective of this exercise was to test the hypothesis that the soil impedance is sensitive to the moisture content of the soil and that the imaginary part (that is, capacitive reactance) can be used to calculate the volumetric water content of the soil. These measurements were compared with gravimetric samples collected at these locations by the FIFE staff science team.

  1. UNIFORMITY ASSESSMENT OF CARBON FIBRES DISPERSION IN CEMENT PASTE BY IMPEDANCE MEASUREMENTS

    Institute of Scientific and Technical Information of China (English)

    1999-01-01

    An alternating current was applied to measure the impedance of a hardened cement paste with various contents of carbon fibres.When the free water content in the hardened cement paste is 90%-98%,and the measuring frequency 500Hz,an approximate linear relationship was found between fibre content and impedance of the composite.Based on this relationship,a new attempt was made to evaluate the dispersion uniformity of carbon fibres in cement paste by impedance measurement.The standard deviation S and the coefficient of vriation S/(X-)i of impedance of the fibre-cement specimens randomly taken locating in different points were used as main parameters for the uniformity assessment.As a case,four different mixing processes were designed for dispersing carbon fibres into the cement paste.The results demonstrate that the relative longer mixing time increases the dispersion uniformity of carbon fibres in cement paste,and the addition of the water reducer dramatically improves the uniformity due to the change of the fluidity of the paste.The ground fly ash can increase the uniformity to a certain extent.

  2. Damage Diagnosis in Semiconductive Materials Using Electrical Impedance Measurements

    Science.gov (United States)

    Ross, Richard W.; Hinton, Yolanda L.

    2008-01-01

    Recent aerospace industry trends have resulted in an increased demand for real-time, effective techniques for in-flight structural health monitoring. A promising technique for damage diagnosis uses electrical impedance measurements of semiconductive materials. By applying a small electrical current into a material specimen and measuring the corresponding voltages at various locations on the specimen, changes in the electrical characteristics due to the presence of damage can be assessed. An artificial neural network uses these changes in electrical properties to provide an inverse solution that estimates the location and magnitude of the damage. The advantage of the electrical impedance method over other damage diagnosis techniques is that it uses the material as the sensor. Simple voltage measurements can be used instead of discrete sensors, resulting in a reduction in weight and system complexity. This research effort extends previous work by employing finite element method models to improve accuracy of complex models with anisotropic conductivities and by enhancing the computational efficiency of the inverse techniques. The paper demonstrates a proof of concept of a damage diagnosis approach using electrical impedance methods and a neural network as an effective tool for in-flight diagnosis of structural damage to aircraft components.

  3. Modern Trends in Imaging XI: Impedance Measurements in the Biomedical Sciences

    Directory of Open Access Journals (Sweden)

    Frederick D. Coffman

    2012-01-01

    Full Text Available Biological organisms and their component organs, tissues and cells have unique electrical impedance properties. Impedance properties often change with changes in structure, composition, and metabolism, and can be indicative of the onset and progression of disease states. Over the past 100 years, instruments and analytical methods have been developed to measure the impedance properties of biological specimens and to utilize these measurements in both clinical and basic science settings. This chapter will review the applications of impedance measurements in the biomedical sciences, from whole body analysis to impedance measurements of single cells and cell monolayers, and how cellular impedance measuring instruments can now be used in high throughput screening applications.

  4. Ionic conductivity measurements of zirconia under pressure using impedance spectroscopy

    CERN Document Server

    Takebe, H; Ohtaka, O; Fukui, H; Yoshiasa, A; Yamanaka, T; Ota, K; Kikegawa, T

    2002-01-01

    We have set up an electrical conductivity measurement system under high-pressure and high-temperature conditions with a multi-anvil high-pressure apparatus using an AC complex impedance method. With this system, we have successfully measured the electrical conductivity of stabilized ZrO sub 2 (Y sub 2 O sub 3 -ZrO sub 2 solid solution) under pressures up to 5 GPa in the temperature range from 300 to 1200 K. The electrical conductivities obtained under pressure are compatible with those of previous results measured at ambient pressure.

  5. On accurate differential measurements with electrochemical impedance spectroscopy

    CERN Document Server

    Kernbach, S; Kernbach, O

    2016-01-01

    This paper describes the impedance spectroscopy adapted for analysis of small electrochemical changes in fluids. To increase accuracy of measurements the differential approach with temperature stabilization of fluid samples and electronics is used. The impedance analysis is performed by the single point DFT, signal correlation, calculation of RMS amplitudes and interference phase shift. For test purposes the samples of liquids and colloids are treated by fully shielded electromagnetic generators and passive cone-shaped structures. Fluidic samples collected from different geological locations are also analysed. In all tested cases we obtained different results for impacted and non-impacted samples, moreover, a degradation of electrochemical stability after treatment is observed. This method is used in laboratory analysis of weak emissions and ensures a high repeatability of results.

  6. Determination of complex microcalorimeter parameters with impedance measurements

    Energy Technology Data Exchange (ETDEWEB)

    Saab, T. [NASA Goddard Space Flight Center, Greenbelt, MD 20771 (United States)]. E-mail: tsaab@phys.ufl.edu; Bandler, S.R. [NASA Goddard Space Flight Center, Greenbelt, MD 20771 (United States); Chervenak, J. [NASA Goddard Space Flight Center, Greenbelt, MD 20771 (United States); Figueroa-Feliciano, E. [NASA Goddard Space Flight Center, Greenbelt, MD 20771 (United States); Finkbeiner, F. [NASA Goddard Space Flight Center, Greenbelt, MD 20771 (United States); Iyomoto, N. [NASA Goddard Space Flight Center, Greenbelt, MD 20771 (United States); Kelley, R.L. [NASA Goddard Space Flight Center, Greenbelt, MD 20771 (United States); Kilbourne, C.A. [NASA Goddard Space Flight Center, Greenbelt, MD 20771 (United States); Lindeman, M.A. [University of Wisconsin, Madison, WI 53706 (United States); Porter, F.S. [NASA Goddard Space Flight Center, Greenbelt, MD 20771 (United States); Sadleir, J. [NASA Goddard Space Flight Center, Greenbelt, MD 20771 (United States)

    2006-04-15

    The proper understanding and modeling of a microcalorimeter's response requires accurate knowledge of a handful of parameters, such as C, G, {alpha}. While a few of these parameters are directly determined from the IV characteristics, some others, notoriously the heat capacity (C) and {alpha}, appear in degenerate combinations in most measurable quantities. The consideration of a complex microcalorimeter leads to an added ambiguity in the determination of the parameters. In general, the dependence of the microcalorimeter's complex impedance on these various parameters varies with frequency. This dependence allows us to determine individual parameters by fitting the prediction of the microcalorimeter model to impedance data. In this paper we describe efforts at characterizing the Goddard X-ray microcalorimeters. With the parameters determined by this method, we compare the pulse shape and noise spectra predictions to data taken with the same devices.

  7. Identifying Ground-Robot Impedance to Improve Terrain Adaptability in Running Robots

    Directory of Open Access Journals (Sweden)

    Juan C. Arevalo

    2015-01-01

    Full Text Available To date, running robots are still outperformed by animals, but their dynamic behaviour can be described by the same model. This coincidence means that biomechanical studies can reveal much about the adaptability and energy efficiency of walking mechanisms. In particular, animals adjust their leg stiffness to negotiate terrains with different stiffnesses to keep the total leg-ground stiffness constant. In this work, we aim to provide one method to identify ground-robot impedance so that control can be applied to emulate the aforementioned animal behaviour. Experimental results of the method are presented, showing well- differentiated estimations on four different types of terrain. Additionally, an analysis of the convergence time is presented and compared with the contact time of humans while running, indicating that the method is suitable for use at high speeds.

  8. Mechanical impedance measurement and damage detection using noncontact laser ultrasound.

    Science.gov (United States)

    Lee, Hyeonseok; Lim, Hyeong Uk; Hong, Jung-Wuk; Sohn, Hoon

    2014-06-01

    This Letter proposes a mechanical impedance (MI) measurement technique using noncontact laser ultrasound. The ultrasound is generated by shooting a pulse laser beam onto a target structure, and its response is measured using a laser vibrometer. Once ultrasound propagation converges to structural vibration, MI is formed over the entire structure. Because noncontact lasers are utilized, this technique is applicable in harsh environments, free of electromagnetic interference, and able to perform wide-range scanning. The formation of MI and its feasibility for damage detection are verified through thermo-mechanical finite element analysis and lab-scale experiments.

  9. Determination of time delay between ventricles contraction using impedance measurements

    Science.gov (United States)

    Lewandowska, M.; Poliński, A.; Wtorek, J.

    2013-04-01

    The paper presents a novel approach to assessment of ventricular dyssynchrony basing on multichannel electrical impedance measurements. Using a proper placement of electrodes, the sensitivity approach allows estimating time difference between chambers contraction from over determined nonlinear system of equations. The theoretical considerations which include Finite Element Method simulations were verified using measurements on healthy 28 year's old woman. The nonlinear least squares method was applied to obtain a time difference between heart chambers contraction. The obtained value was in a good agreement with theoretical values found in literature.

  10. Spatially resolved voltage, current and electrochemical impedance spectroscopy measurements

    Energy Technology Data Exchange (ETDEWEB)

    Gerteisen, D.; Kurz, T.; Schwager, M.; Hebling, C. [Fraunhofer Institute for Solar Energy Systems ISE, Freiburg im Breisgau (Germany); Merida, W. [Clean Energy Research Centre, University of British Columbia, Vancouver, BC (Canada); Lupotto, P. [Materials Mates Italia, Milano (Italy)

    2011-04-15

    In this work a 50-channel characterisation system for PEMFCs is presented. The system is capable of traditional electrochemical measurements (e.g. staircase voltammetry, chronoamperometry and cyclic voltammetry), and concurrent EIS measurements. Unlike previous implementations, this system relies on dedicated potentiostats for current and voltage control, and independent frequency response analysers (FRAs) at each channel. Segmented fuel cell hardware is used to illustrate the system's flexibility and capabilities. The results here include steady-state data for cell characterisation under galvanostatic and potentiostatic control as well as spatially resolved impedance spectra. (Copyright copyright 2011 WILEY-VCH Verlag GmbH and Co. KGaA, Weinheim)

  11. Study of surfactant-skin interactions by skin impedance measurements.

    Science.gov (United States)

    Lu, Guojin; Moore, David J

    2012-02-01

    The stratum corneum (SC) plays a very critical physiological role as skin barrier in regulating water loss through the skin and protects the body from a wide range of physical and chemical exogenous insults. Surfactant-containing formulations can induce skin damage and irritation owing to surfactant absorption and penetration. It is generally accepted that reduction in skin barrier properties occurs only after surfactants have penetrated/permeated into the skin barrier. To mitigate the harshness of surfactant-based cleansing products, penetration/permeation of surfactants should be reduced. Skin impedance measurements have been taken in vitro on porcine skin using vertical Franz diffusion cells to investigate the impact of surfactants, temperature and pH on skin barrier integrity. These skin impedance results demonstrate excellent correlation with other published methods for assessing skin damage and irritation from different surfactant chemistry, concentration, pH, time of exposure and temperature. This study demonstrates that skin impedance can be utilized as a routine approach to screen surfactant-containing formulations for their propensity to compromise the skin barrier and hence likely lead to skin irritation.

  12. Biomass measurement of living Lumbriculus variegatus with impedance spectroscopy

    Directory of Open Access Journals (Sweden)

    Martina Sammer

    2014-12-01

    Full Text Available Impedance spectroscopy is a useful tool for non-invasive and real time measurements of cell suspensions and a variety of biological tissues. The objective of this study was the investigation of the dielectric properties of living aquatic worms (Lumbriculus variegatus using impedance spectroscopy in a frequency range between 100 Hz and 10 MHz. We demonstrate a linear relation between the worm biomass and the phase response of the signal thereby providing a quick and precise method to determine the biomass of aquatic worms in situ. Possible applications for non-destructive online biomass monitoring of aquatic worms and other aqueous organisms are discussed. Furthermore, we show that groups of worms fed different diets can be distinguished by the method presented. These results reveal a close relationship between the nutritional composition of the worms and the measured phase response. We also demonstrate that the phase response at 90 kHz does not depend on the worm size. In contrast, the response function for the signal at 440 Hz reveals a linear correlation of average individual worm size and phase. Therefore, we conclude that the measured phase response at 90 kHz qualifies as a measure of the total amount of worm biomass present in the measuring cell, whereas the phase measurement at 440 Hz can be used to estimate the average individual worm size. 

  13. Crosstalk Compensation for a Rapid, Higher Resolution Impedance Spectrum Measurement

    Energy Technology Data Exchange (ETDEWEB)

    Jon P. Christophersen; John L. Morrison; David M. Rose; William H. Morrison; Chester G. Motloch

    2012-03-01

    Batteries and other energy storage devices are playing larger roles in various industries (e.g., military, automotive, electric utilities, etc.) as the U.S. seeks to reduce its dependence on foreign energy resources. As such, there exists a significant need for accurate, robust state-of-health assessment techniques. Present techniques tend to focus on simple, passive monitoring of voltage and current at a given ambient temperature. However, this approach has the disadvantage of ignoring key elements of health, that is, changes in resistance growth and power fade. Impedance spectroscopy is considered a useful laboratory tool in gauging changes in the resistance and power performance, but it has not been widely considered as an onboard diagnostic tool due to the length of time required to complete the measurement. Cross-Talk Compensation (CTC) is a novel approach that enables rapid, high resolution impedance spectra measurements using a hardware platform that could be designed as an embedded system. This input signal consists of a sum-of-sines excitation current that has a known frequency spread and a duration of one period of the lowest frequency. The voltage response is then captured at a sufficiently fast sample rate. Previously developed rapid impedance spectrum measurement techniques either required a longer excitation signal or a sum-of-sines signal that was separated by harmonic frequencies to reduce or eliminate, respectively, the cross-talk interference in the calculated results. The distinct advantage of CTC, however, is that non-harmonic frequencies can now be included within the excitation signal while still keeping the signal duration at one period of the lowest frequency. Since the frequency spread of the input signal is known, the crosstalk interference between sinusoidal signals within the sum-of-sines at a given frequency of interest can be pre-determined and assigned to an error matrix. Consequently, the real and imaginary components of the

  14. RF impedance measurements of DC atmospheric micro-discharges

    CERN Document Server

    Overzet, Lawrence J; Mandra, Monali; Goeckner, Matthew; Dufour, Thierry; Dussart, Remi; Lefaucheux, Philippe

    2016-01-01

    The available diagnostics for atmospheric micro-plasmas remain limited and relatively complex to implement; so we present a radio-frequency technique for diagnosing a key parameter here. The technique allows one to estimate the dependencies of the electron density by measuring the RF-impedance of the micro-plasma and analyzing it with an appropriate equivalent circuit. This technique is inexpensive, can be used in real time and gives reasonable results for argon and helium DC micro-plasmas in holes over a wide pressure range. The electron density increases linearly with current in the expected range consistent with normal glow discharge behavior.

  15. Auditory evoked field measurement using magneto-impedance sensors

    Energy Technology Data Exchange (ETDEWEB)

    Wang, K., E-mail: o-kabou@echo.nuee.nagoya-u.ac.jp; Tajima, S.; Song, D.; Uchiyama, T. [Graduate School of Engineering, Nagoya University, Nagoya (Japan); Hamada, N.; Cai, C. [Aichi Steel Corporation, Tokai (Japan)

    2015-05-07

    The magnetic field of the human brain is extremely weak, and it is mostly measured and monitored in the magnetoencephalography method using superconducting quantum interference devices. In this study, in order to measure the weak magnetic field of the brain, we constructed a Magneto-Impedance sensor (MI sensor) system that can cancel out the background noise without any magnetic shield. Based on our previous studies of brain wave measurements, we used two MI sensors in this system for monitoring both cerebral hemispheres. In this study, we recorded and compared the auditory evoked field signals of the subject, including the N100 (or N1) and the P300 (or P3) brain waves. The results suggest that the MI sensor can be applied to brain activity measurement.

  16. Determinants of pulmonary perfusion measured by electrical impedance tomography.

    Science.gov (United States)

    Smit, Henk J; Vonk Noordegraaf, Anton; Marcus, J Tim; Boonstra, Anco; de Vries, Peter M; Postmus, Pieter E

    2004-06-01

    Electrical impedance tomography (EIT) is a non-invasive imaging technique for detecting blood volume changes that can visualize pulmonary perfusion. The two studies reported here tested the hypothesis that the size of the pulmonary microvascular bed, rather than stroke volume (SV), determines the EIT signal. In the first study, the impedance changes relating to the maximal pulmonary pulsatile blood volume during systole (Delta Z(sys)) were measured in ten healthy subjects, ten patients diagnosed with chronic obstructive pulmonary disease, who were considered to have a reduced pulmonary vascular bed, and ten heart failure patients with an assumed low cardiac output but with a normal lung parenchyma. Mean Delta Z(sys) (SD) in these groups was 261 (34)x10(-5), 196 (39)x10(-5) ( Pbicycle while SV was measured by means of magnetic resonance imaging. The Delta Z(sys) at rest was 352 (53)x10(-5 ) and 345 (112)x10(-5 )AU during exercise (P=NS), whereas SV increased from 83 (21) to 105 (34) ml (P<0.05). The EIT signal likely reflects the size of the pulmonary microvascular bed, since neither a low cardiac output nor a change in SV of the heart appear to influence EIT.

  17. Electrical conduction in polycrystalline CVD diamond: Temperature dependent impedance measurements

    Energy Technology Data Exchange (ETDEWEB)

    Ye, H.; Williams, O.A.; Jackman, R.B. [Electronic and Electrical Engineering, University College London, Torrington Place, London WC1E 7JE (United Kingdom); Rudkin, R.; Atkinson, A. [Department of Materials, Imperial College London, South Kensington, London SW7 2AZ (United Kingdom)

    2002-10-16

    In this paper, we report the first measurement of impedance on freestanding diamond films from 0.1 Hz to 10 MHz up to 300 C. A wide range of CVD materials have been investigated, but here we concentrate on 'black' diamond grown by MWPECVD. The Cole-Cole (Z' via Z{sup ''}) plots are well fitted to a RC parallel circuit model and the equivalent resistance and capacitance for the diamond films have been estimated using the Zview curve fitting. The results show only one single semicircle response at each temperature measured. It was found that the resistance decreases from 62 M{omega} at room temperature to 4 k{omega} at 300 C, with an activation energy around 0.51 eV. The equivalent capacitance is maintained at the level of 10{sup 2} pF up to 300 C, suggesting that the diamond grain boundaries are dominating the conduction. At 400 C, the impedance at low frequencies shows a linear tail, which can be explained that the ac polarization of diamond/Au interface occurs. (Abstract Copyright [2002], Wiley Periodicals, Inc.)

  18. Quantitative assessment of impedance tomography for temperature measurements in hyperthermia.

    Science.gov (United States)

    Blad, B; Persson, B; Lindström, K

    1992-01-01

    The objective of this study is a non-invasive assessment of the thermal dose in hyperthermia. Electrical impedance tomography (EIT) has previously been given a first trial as a temperature monitoring method together with microwave-induced hyperthermia treatment, but it has not been thoroughly investigated. In the present work we have examined this method in order to investigate the correlation in vitro between the true spatial temperature distribution and the corresponding measured relative resistivity changes. Different hyperthermia techniques, such as interstitial water tubings, microwave-induced, laser-induced and ferromagnetic seeds have been used. The results show that it is possible to find a correlation between the measured temperature values and the tomographically measured relative resistivity changes in tissue-equivalent phantoms. But the uncertainty of the temperature coefficients, which has been observed, shows that the method has to be improved before it can be applied to clinical in vivo applications.

  19. Evaluation of different methods for measuring the impedance of Lithium-ion batteries during ageing

    DEFF Research Database (Denmark)

    Stroe, Daniel Loan; Swierczynski, Maciej Jozef; Stroe, Ana-Irina

    2015-01-01

    The impedance represents one of the most important performance parameters of the Lithium-ion batteries since it used for power capability calculations, battery pack and system design, cooling system design and also for state-of-health estimation. In the literature, different approaches...... are presented for measuring the impedance of Lithium-ion batteries and electrochemical impedance spectroscopy and dc current pulses are the most used ones; each of these approaches has its own advantages and drawbacks. The goal of this paper is to investigate which of the most encountered impedance measurement...... approaches is the most suitable for measuring the impedance of Lithium-ion batteries during ageing....

  20. Wideband impedance measurements and modeling of DC motors for EMI predictions

    NARCIS (Netherlands)

    Diouf, F.; Leferink, Frank Bernardus Johannes; Duval, Fabrice; Bensetti, Mohamed

    2015-01-01

    In electromagnetic interference prediction, dc motors are usually modeled as a source and a series impedance. Previous researches only include the impedance of the armature, while neglecting the effect of the motor's rotation. This paper aims at measuring and modeling the wideband impedance of a dc

  1. Wideband impedance measurements and modeling of DC motors for EMI predictions

    NARCIS (Netherlands)

    Diouf, Fatou; Leferink, Frank; Duval, Fabrice; Bensetti, Mohamed

    2015-01-01

    In electromagnetic interference prediction, dc motors are usually modeled as a source and a series impedance. Previous researches only include the impedance of the armature, while neglecting the effect of the motor's rotation. This paper aims at measuring and modeling the wideband impedance of a dc

  2. An Electronic Measurement Instrumentation of the Impedance of a Loaded Fuel Cell or Battery

    OpenAIRE

    2007-01-01

    In this paper we present an inexpensive electronic measurement instrumentation developed in our laboratory, to measure and plot the impedance of a loaded fuel cell or battery. Impedance measurements were taken by using the load modulation method. This instrumentation has been developed around a VXI system stand which controls electronic cards. Software under Hpvee® was developed for automatic measurements and the layout of the impedance of the fuel cell on load. The measurement environment, l...

  3. Feature Extraction Method for High Impedance Ground Fault Localization in Radial Power Distribution Networks

    DEFF Research Database (Denmark)

    Jensen, Kåre Jean; Munk, Steen M.; Sørensen, John Aasted

    1998-01-01

    processes and communication systems lead to demands for improved monitoring of power distribution networks so that the quality of power delivery can be kept at a controlled level. The ground fault localization method for each feeder in a network is based on the centralized frequency broadband measurement...... of three phase voltages and currents. The method consists of a feature extractor, based on a grid description of the feeder by impulse responses, and a neural network for ground fault localization. The emphasis of this paper is the feature extractor, and the detection of the time instance of a ground fault...

  4. High Input Impedance Voltage-Mode Universal Biquadratic Filters With Three Inputs Using Three CCs and Grounding Capacitors

    Directory of Open Access Journals (Sweden)

    J. W. Horng

    2012-04-01

    Full Text Available Two current conveyors (CCs based high input impedance voltage-mode universal biquadratic filters each with three input terminals and one output terminal are presented. The first circuit is composed of three differential voltage current conveyors (DVCCs, two grounded capacitors and four resistors. The second circuit is composed of two DVCCs, one differential difference current conveyor (DDCC, two grounded capacitors and four grounded resistors. The proposed circuits can realize all the standard filter functions, namely, lowpass, bandpass, highpass, notch and allpass filters by the selections of different input voltage terminals. The proposed circuits offer the features of high input impedance, using only grounded capacitors and low active and passive sensitivities. Moreover, the x ports of the DVCCs (or DDCC in the proposed circuits are connected directly to resistors. This design offers the feature of a direct incorporation of the parasitic resistance at the x terminal of the DVCC (DDCC, Rx, as a part of the main resistance.

  5. DVCCs Based High Input Impedance Voltage-Mode First-Order Filters Employing Grounded Capacitor and Resistor

    Directory of Open Access Journals (Sweden)

    J. W. Horng

    2010-12-01

    Full Text Available A voltage-mode high input impedance first-order highpass, lowpass and allpass filters using two differential voltage current conveyors (DVCCs, one grounded capacitor and one grounded resistor is presented. The highpass, lowpass and allpass signals can be obtained simultaneously from the circuit configuration. The suggested filter uses a canonical number of passive components without requiring any component matching condition. The simulation results confirm the theoretical analysis.

  6. An effective measured data preprocessing method in electrical impedance tomography.

    Science.gov (United States)

    Yu, Chenglong; Yue, Shihong; Wang, Jianpei; Wang, Huaxiang

    2014-01-01

    As an advanced process detection technology, electrical impedance tomography (EIT) has widely been paid attention to and studied in the industrial fields. But the EIT techniques are greatly limited to the low spatial resolutions. This problem may result from the incorrect preprocessing of measuring data and lack of general criterion to evaluate different preprocessing processes. In this paper, an EIT data preprocessing method is proposed by all rooting measured data and evaluated by two constructed indexes based on all rooted EIT measured data. By finding the optimums of the two indexes, the proposed method can be applied to improve the EIT imaging spatial resolutions. In terms of a theoretical model, the optimal rooting times of the two indexes range in [0.23, 0.33] and in [0.22, 0.35], respectively. Moreover, these factors that affect the correctness of the proposed method are generally analyzed. The measuring data preprocessing is necessary and helpful for any imaging process. Thus, the proposed method can be generally and widely used in any imaging process. Experimental results validate the two proposed indexes.

  7. Electrical impedance spectroscopy for measuring the impedance response of carbon-fiber-reinforced polymer composite laminates

    KAUST Repository

    Almuhammadi, Khaled

    2017-02-16

    Techniques that monitor the change in the electrical properties of materials are promising for both non-destructive testing and structural health monitoring of carbon-fiber-reinforced polymers (CFRPs). However, achieving reliable monitoring using these techniques requires an in-depth understanding of the impedance response of these materials when subjected to an alternating electrical excitation, information that is only partially available in the literature. In this work, we investigate the electrical impedance spectroscopy response at various frequencies of laminates chosen to be representative of classical layups employed in composite structures. We clarify the relationship between the frequency of the electrical current, the conductivity of the surface ply and the probing depth for different CFRP configurations for more efficient electrical signal-based inspections. We also investigate the effect of the amplitude of the input signal.

  8. Numerical analysis of complex impedance and microwave absorption of metamaterials composed of split cut wires on grounded dielectric substrate

    Science.gov (United States)

    Lim, Jun-Hee; Liu, Tian; Kim, Sung-Soo

    2014-06-01

    The microwave absorption of metamaterials composed of split cut wire (SCW) on grounded dielectric substrate has been investigated on the basis of equivalent transmission line circuit. S-parameters (S 11 and S 21) and input impedance are numerically simulated with variations of the thickness and dielectric loss of the substrate and the geometry of the SCW. Magnetic resonance resulting from antiparallel currents between SCW and ground plane was observed at the frequency of minimum reflection loss. The simulated resonance frequency and reflection loss can be explained well on the basis of the circuit theory of an LC resonator. Analysis of the input impedance of the high impedance surface has shown that perfect absorption can be obtained at the optimized impedance-matching condition, which is dependent on SCW width, thickness and the dielectric loss of the substrate. Better insight into the absorption mechanism of metamaterial absorbers can be attained through the parametric analysis on complex impedance of SCW and its relationship with reflection loss.

  9. In-Vivo Electrical Impedance Measurement in Mastoid Bone.

    Science.gov (United States)

    Wyss Balmer, Thomas; Ansó, Juan; Muntane, Enric; Gavaghan, Kate; Weber, Stefan; Stahel, Andreas; Büchler, Philippe

    2017-04-01

    Nerve monitoring is a safety mechanism to detect the proximity between surgical instruments and important nerves during surgical bone preparation. In temporal bone, this technique is highly specific and sensitive at distances below 0.1 mm, but remains unreliable for distances above this threshold. A deeper understanding of the patient-specific bone electric properties is required to improve this range of detection. A sheep animal model has been used to characterize bone properties in vivo. Impedance measurements have been performed at low frequencies (drilled into the sheep mastoid bone. An electric circuit composed of a resistor and a Fricke constant phase element was able to accurately describe the experimental measurements. Bone resistivity was shown to be linearly dependent on the inter-electrode distance and the local bone density. Based on this model, the amount of bone material between the electrodes could be predicted with an error of 0.7 mm. Our results indicate that bone could be described as an ideal resistor while the electrochemical processes at the electrode-tissue interface are characterized by a constant phase element. These results should help increasing the safety of surgical drilling procedures by better predicting the distance to critical nerve structures.

  10. Analytic modeling, simulation and interpretation of broadband beam coupling impedance bench measurements

    Energy Technology Data Exchange (ETDEWEB)

    Niedermayer, U., E-mail: niedermayer@temf.tu-darmstadt.de [Institut für Theorie Elektromagnetischer Felder (TEMF), Technische Universität Darmstadt, Schloßgartenstraße 8, 64289 Darmstadt (Germany); Eidam, L. [Institut für Theorie Elektromagnetischer Felder (TEMF), Technische Universität Darmstadt, Schloßgartenstraße 8, 64289 Darmstadt (Germany); Boine-Frankenheim, O. [Institut für Theorie Elektromagnetischer Felder (TEMF), Technische Universität Darmstadt, Schloßgartenstraße 8, 64289 Darmstadt (Germany); GSI Helmholzzentrum für Schwerionenforschung, Planckstraße 1, 64291 Darmstadt (Germany)

    2015-03-11

    First, a generalized theoretical approach towards beam coupling impedances and stretched-wire measurements is introduced. Applied to a circular symmetric setup, this approach allows to compare beam and wire impedances. The conversion formulas for TEM scattering parameters from measurements to impedances are thoroughly analyzed and compared to the analytical beam impedance solution. A proof of validity for the distributed impedance formula is given. The interaction of the beam or the TEM wave with dispersive material such as ferrite is discussed. The dependence of the obtained beam impedance on the relativistic velocity β is investigated and found as material property dependent. Second, numerical simulations of wakefields and scattering parameters are compared. The applicability of scattering parameter conversion formulas for finite device length is investigated. Laboratory measurement results for a circularly symmetric test setup, i.e. a ferrite ring, are shown and compared to analytic and numeric models. The optimization of the measurement process and error reduction strategies are discussed.

  11. Simultaneous Measurement of Nonlinearity and Electrochemical Impedance for Protein Sensing Using Two-Tone Excitation

    Science.gov (United States)

    Daniels, Jonathan S.; Anderson, Erik P.; Lee, Thomas H.; Pourmand, Nader

    2009-01-01

    Impedance biosensors detect the binding of a target to an immobilized probe by quantifying changes in the impedance of the electrode-electrolyte interface. The interface's I-V relationship is inherently nonlinear, varying with DC bias, and target binding can alter the degree of nonlinearity. We propose and demonstrate a method to simultaneously measure the nonlinearity and conventional small-signal impedance using intermodulation products from a two-tone input. Intermodulation amplitudes accurately reflect the impedance's manually-measured voltage dependence. We demonstrate that changes in nonlinearity can discriminate protein binding. Our measurements suggest that target binding can alter nonlinearity via the voltage dependence of the ionic double layer. PMID:19164024

  12. Estimation of source location and ground impedance using a hybrid multiple signal classification and Levenberg-Marquardt approach

    Science.gov (United States)

    Tam, Kai-Chung; Lau, Siu-Kit; Tang, Shiu-Keung

    2016-07-01

    A microphone array signal processing method for locating a stationary point source over a locally reactive ground and for estimating ground impedance is examined in detail in the present study. A non-linear least square approach using the Levenberg-Marquardt method is proposed to overcome the problem of unknown ground impedance. The multiple signal classification method (MUSIC) is used to give the initial estimation of the source location, while the technique of forward backward spatial smoothing is adopted as a pre-processer of the source localization to minimize the effects of source coherence. The accuracy and robustness of the proposed signal processing method are examined. Results show that source localization in the horizontal direction by MUSIC is satisfactory. However, source coherence reduces drastically the accuracy in estimating the source height. The further application of Levenberg-Marquardt method with the results from MUSIC as the initial inputs improves significantly the accuracy of source height estimation. The present proposed method provides effective and robust estimation of the ground surface impedance.

  13. Measurement uncertainty in pulmonary vascular input impedance and characteristic impedance estimated from pulsed-wave Doppler ultrasound and pressure: clinical studies on 57 pediatric patients.

    Science.gov (United States)

    Tian, Lian; Hunter, Kendall S; Kirby, K Scott; Ivy, D Dunbar; Shandas, Robin

    2010-06-01

    Pulmonary vascular input impedance better characterizes right ventricular (RV) afterload and disease outcomes in pulmonary hypertension compared to the standard clinical diagnostic, pulmonary vascular resistance (PVR). Early efforts to measure impedance were not routine, involving open-chest measurement. Recently, the use of pulsed-wave (PW) Doppler-measured velocity to non-invasively estimate instantaneous flow has made impedance measurement more practical. One critical concern remains with clinical use: the measurement uncertainty, especially since previous studies only incorporated random error. This study utilized data from a large pediatric patient population to comprehensively examine the systematic and random error contributions to the total impedance uncertainty and determined the least error prone methodology to compute impedance from among four different methods. We found that the systematic error contributes greatly to the total uncertainty and that one of the four methods had significantly smaller propagated uncertainty; however, even when this best method is used, the uncertainty can be large for input impedance at high harmonics and for the characteristic impedance modulus. Finally, we found that uncertainty in impedance between normotensive and hypertensive patient groups displays no significant difference. It is concluded that clinical impedance measurement would be most improved by advancements in instrumentation, and the best computation method is proposed for future clinical use of the input impedance.

  14. Ambulatory Measurement of Ground Reaction Forces

    NARCIS (Netherlands)

    Veltink, Petrus H.; Liedtke, C.B.; Droog, Adriaan

    2004-01-01

    The measurement of ground reaction forces is important in the biomechanical analysis of gait and other motor activities. It is the purpose of this study to show the feasibility of ambulatory measurement of ground reaction forces using two six degrees of freedom sensors mounted under the shoe. One

  15. Beam Coupling Impedance Localization Technique Validation and Measurements in the CERN Machines

    CERN Document Server

    Biancacci, N; Argyropoulos, T; Bartosik, H; Calaga, R; Cornelis, K; Gilardoni, S; Métral, E; Mounet, N; Papaphilippou, Y; Persichelli, S; Rumolo, G; Salvant, B; Sterbini, G; Tomàs, R; Wasef, R; Migliorati, M; Palumbo, L

    2013-01-01

    The beam coupling impedance could lead to limitations in beam brightness and quality, and therefore it needs accurate quantification and continuous monitoring in order to detect and mitigate high impedance sources. In the CERN machines, for example, kickers and collimators are expected to be important contributors to the total imaginary part of the transverse impedance. In order to detect the other sources, a beam based measurement was developed: from the variation of betatron phase beating with intensity, it is possible to detect the locations of main impedance sources. In this work we present the application of the method with beam measurements in the CERN PS, SPS and LHC.

  16. A Harmonic Impedance Measurement System for Reduction of Harmonics in the Electricity Grid

    NARCIS (Netherlands)

    Heskes, P.J.M.; Myrzik, J.M.A.; Kling, W.L.

    2009-01-01

    This paper describes the development of a Complex Harmonic Impedance Measurement system, called the CHIME-system. This system performs on-line impedance measurements in the electricity grid and will be designed for implementation in Digital Signal Processor (DSP) control systems of grid-connected el

  17. An impedance-measurement setup optimized for measuring relaxations of glass-forming liquids.

    Science.gov (United States)

    Igarashi, Brian; Christensen, Tage; Larsen, Ebbe H; Olsen, Niels Boye; Pedersen, Ib H; Rasmussen, Torben; Dyre, Jeppe C

    2008-04-01

    An electronics system has been assembled to measure frequency-dependent response functions of glass-forming liquids in the extremely viscous state approaching the glass transition. We determine response functions such as dielectric permittivity and shear and bulk moduli by measuring electrical impedances of liquid-filled transducers, and this technique requires frequency generators capable of producing signals that are reproducible over the span of several days or even several weeks. To this end, we have constructed a frequency generator that produces low-frequency (1 mHz-100 Hz) sinusoidal signals with voltages that are reproducible within 10 ppm. Two factors that partly account for this precision are that signals originate from voltages stored in a look-up table and that only coil-less filters are used in this unit, which significantly reduces fluctuations of output caused by changes of temperatures of circuits. This generator also includes a special triggering facility that makes it possible to measure up to 512 voltages per cycle that are spaced apart at uniform phase intervals. Fourier transformations of such data yield precise determinations of complex amplitudes of voltages and currents applied to a transducer, which ultimately allows us to determine electrical impedances of transducers with a reproducibility error that is only a few parts per hundred thousand. This equipment is used in tandem with a commercial LCR meter and/or impedance analyzer that give(s) impedance measurements at higher frequencies, up to 1 MHz. The experimental setup allows measurements of the transducer impedance over nine decades of frequency within a single run.

  18. Measurement of ground motion in various sites

    Energy Technology Data Exchange (ETDEWEB)

    Bialowons, W.; Amirikas, R.; Bertolini, A.; Kruecker, D.

    2007-04-15

    Ground vibrations may affect low emittance beam transport in linear colliders, Free Electron Lasers (FEL) and synchrotron radiation facilities. This paper is an overview of a study program to measure ground vibrations in various sites which can be used for site characterization in relation to accelerator design. Commercial broadband seismometers have been used to measure ground vibrations and the resultant database is available to the scientific community. The methodology employed is to use the same equipment and data analysis tools for ease of comparison. This database of ground vibrations taken in 19 sites around the world is first of its kind. (orig.)

  19. Wideband impedance measurements of DC motors under dynamic load conditions

    NARCIS (Netherlands)

    Diouf, F.; Buesink, Frederik Johannes Karel; Leferink, Frank Bernardus Johannes; Duval, Fabrice; Bensetti, Mohamed

    2013-01-01

    One of the principal conducted EMI(electromagnetic interferences) sources of low voltage DC (direct current) motors is the commutation occurring during rotation. In this paper the small-signal impedance of low voltage DC motors under different functioning modes, including the dynamic one is studied

  20. Wideband impedance measurements of DC motors under dynamic load conditions

    NARCIS (Netherlands)

    Diouf, Fatou; Buesink, Frits; Leferink, Frank; Duval, Fabrice; Bensetti, Mohamed

    2013-01-01

    One of the principal conducted EMI(electromagnetic interferences) sources of low voltage DC (direct current) motors is the commutation occurring during rotation. In this paper the small-signal impedance of low voltage DC motors under different functioning modes, including the dynamic one is studied

  1. Kicker impedance measurements for the future multiturn extraction of the CERN Proton Synchrotron

    CERN Document Server

    Métral, Elias; Giovannozzi, Massimo; Grudiev, Alexei; Kroyer, Tom; Sermeus, Luc

    2006-01-01

    In the context of the novel multi-turn extraction, where charged particles are trapped into stable islands in transverse phase space, the ejection of five beamlets will be performed by means of a set of three new kickers. Before installing them into the machine, a measurement campaign has been launched to evaluate the impedance of such devices. Two measurement techniques were used to try to disentangle the driving and detuning impedances. The first consists in measuring the longitudinal impedance for different transverse offsets using a single displaced wire. The sum of the transverse driving and detuning impedances is then deduced applying Panofsky- Wenzel theorem. The second uses two wires excited in opposite phase and yields the driving transverse impedance only. Finally, the consequences on the beam dynamics are also analyzed.

  2. Measurement of grid impedance by a medium frequency converter; Netzimpedanzmessung mithilfe eines Mittelfrequenzumrichters

    Energy Technology Data Exchange (ETDEWEB)

    Xie Jian [Ulm Univ. (Germany). Inst. fuer Energiewandlung und -speicherung; Krap, Norbert; Keiper, Heiko [DB Energie GmbH (Germany)

    2008-08-15

    Electric power supply grids today are subject to voltage and current harmonics. Frequency converters contribute to this effect. The frequency curves of the grid impedances are important parameters for assessing the feedback effects of frequency converters. Network impedance in HV grids can be measured by various methods. (orig.)

  3. Nondestructive Determination of Moisture Content in Dry Fruits by Impedance and Phase angle measurements

    Science.gov (United States)

    Impedance (Z), and phase angle (') of a cylindrical parallel-plate capacitor with dry fruits between the plates was measured using a CI meter (Chari’s Impedance meter), at 1 and 9 MHz . Capacitance, C was derived from Z and ', and using the C, ', and Z values of a set of cherries whose moisture con...

  4. An electrode polarization impedance based flow sensor for low water flow measurement

    Science.gov (United States)

    Yan, Tinghu; Sabic, Darko

    2013-06-01

    This note describes an electrode polarization impedance based flow sensor for low water flow measurement. It consists of two pairs of stainless steel electrodes set apart and inserted into a non-conductive flow tube with each pair of electrodes placed diametrically at the opposite sides. The flow sensor is modeled as a typical four-electrode system of which two electrodes are current-carrying and the other two serve as output pick ups. The polarization impedances of the two current carrying electrodes are affected by water flows resulting in changes of differential potential between the two pick-up electrodes which are separated by the same fluid. The interrogation of the two excitation electrodes with dc biased ac signals offers significantly higher sensor sensitivities to flow. The prototype flow sensor constructed for a 20 mm diameter pipeline was able to measure water flow rate as low as tested at 1.06 l h-1 and remained sensitive at a flow rate of 25.18 l h-1 when it was driven with a sinusoidal voltage at 1000 Hz with a peak ac amplitude of 2 V and a dc offset of +8 V. The nonlinear characteristics of the sensor response indicate that the sensor is more sensitive at low flows and will not be able to measure at very high flows. Additional experiments are needed to evaluate the influences of impurities, chemical species, ions constituents, conductivity and temperature over a practical range of residential water conditions, the effects of fluctuating ground signals, measurement uncertainty, power consumption, compensation of effects and practical operations. The flow sensor (principle) presented may be used as (in) a secondary sensor in combination with an existing electronic water meter to extend the low end of measurement range in residential water metering.

  5. Accurate position estimation methods based on electrical impedance tomography measurements

    Science.gov (United States)

    Vergara, Samuel; Sbarbaro, Daniel; Johansen, T. A.

    2017-08-01

    Electrical impedance tomography (EIT) is a technology that estimates the electrical properties of a body or a cross section. Its main advantages are its non-invasiveness, low cost and operation free of radiation. The estimation of the conductivity field leads to low resolution images compared with other technologies, and high computational cost. However, in many applications the target information lies in a low intrinsic dimensionality of the conductivity field. The estimation of this low-dimensional information is addressed in this work. It proposes optimization-based and data-driven approaches for estimating this low-dimensional information. The accuracy of the results obtained with these approaches depends on modelling and experimental conditions. Optimization approaches are sensitive to model discretization, type of cost function and searching algorithms. Data-driven methods are sensitive to the assumed model structure and the data set used for parameter estimation. The system configuration and experimental conditions, such as number of electrodes and signal-to-noise ratio (SNR), also have an impact on the results. In order to illustrate the effects of all these factors, the position estimation of a circular anomaly is addressed. Optimization methods based on weighted error cost functions and derivate-free optimization algorithms provided the best results. Data-driven approaches based on linear models provided, in this case, good estimates, but the use of nonlinear models enhanced the estimation accuracy. The results obtained by optimization-based algorithms were less sensitive to experimental conditions, such as number of electrodes and SNR, than data-driven approaches. Position estimation mean squared errors for simulation and experimental conditions were more than twice for the optimization-based approaches compared with the data-driven ones. The experimental position estimation mean squared error of the data-driven models using a 16-electrode setup was less

  6. IMPEDANCE METHOD OF MEASURING OF THE TITRATABLE ACIDITY OF YOGURT

    Directory of Open Access Journals (Sweden)

    Miroslav Vasilev

    2016-10-01

    Full Text Available In the present work are analyzed studies related to changes in the active impedance component of the dairy environment caused by the flow of lactic fermentation and coagulation of casein in milk. The aim of this work was to determine the relationship between the relative change of titratable acidity and the relative change of active impedance component of the dairy environment with lactic fermentation, causing coagulation of the casein in milk. . The data were interpolated with cubic spline, visualizing how when the fat content increases, the electrical resistance increases too. All data, collected during the tests would complement and be used for solving the optimization problem to determine the time of completion of the coagulation in future work.

  7. Local transverse coupling impedance measurements in a synchrotron light source from turn-by-turn acquisitions

    Science.gov (United States)

    Carlà, Michele; Benedetti, Gabriele; Günzel, Thomas; Iriso, Ubaldo; Martí, Zeus

    2016-12-01

    Transverse beam coupling impedance is a source of beam instabilities that limits the machine performance in circular accelerators. Several beam based techniques have been used to measure the transverse impedance of an accelerator, usually based on the optics distortion produced by the impedance source itself. Beam position monitor turn-by-turn analysis for impedance characterization has been usually employed in large circumference machines, while synchrotron light sources have mainly used slow orbit based techniques. Instead, the work presented in this paper uses for the first time turn-by-turn data at ALBA to advance the measurement technique into the range of the typically small impedance values of modern light sources. We have measured local impedance contributions through the observation of phase advance versus bunch charge using the betatron oscillations excited with a fast dipole kicker. The ALBA beam position monitor system and the precision of the turn-by-turn analysis allowed to characterize the main sources of transverse impedance, in good agreement with the model values, including the impedance of an in-vacuum undulator.

  8. Local transverse coupling impedance measurements in a synchrotron light source from turn-by-turn acquisitions

    Directory of Open Access Journals (Sweden)

    Michele Carlà

    2016-12-01

    Full Text Available Transverse beam coupling impedance is a source of beam instabilities that limits the machine performance in circular accelerators. Several beam based techniques have been used to measure the transverse impedance of an accelerator, usually based on the optics distortion produced by the impedance source itself. Beam position monitor turn-by-turn analysis for impedance characterization has been usually employed in large circumference machines, while synchrotron light sources have mainly used slow orbit based techniques. Instead, the work presented in this paper uses for the first time turn-by-turn data at ALBA to advance the measurement technique into the range of the typically small impedance values of modern light sources. We have measured local impedance contributions through the observation of phase advance versus bunch charge using the betatron oscillations excited with a fast dipole kicker. The ALBA beam position monitor system and the precision of the turn-by-turn analysis allowed to characterize the main sources of transverse impedance, in good agreement with the model values, including the impedance of an in-vacuum undulator.

  9. Anisotropy of human muscle via non invasive impedance measurements. Frequency dependence of the impedance changes during isometric contractions

    Science.gov (United States)

    Kashuri, Hektor

    In this thesis we present non invasive muscle impedance measurements using rotatable probes extending the work done by Aaron et al. (1997) by measuring not only the real part of the impedance but the imaginary part as well. The results reveal orientations of underlying muscle fibers via minima in resistance and reactance versus angle curves, suggesting this method as potentially useful for studying muscle properties in clinical and physiological research. Calculations of the current distribution for a slab of material with anisotropic conductivity show that the current distribution depends strongly on the separation of two current electrodes and as well as on its conducting anisotropy. Forearm muscle impedance measurements at 50 kHz done by Shiffman et al. (2003) had shown that both resistance (R) and reactance (X) increase during isometric contraction. We have extended these measurements in the 3 to 100 kHz range and we found that resistance (R) and reactance (X) both increase and their changes increased or decreased at frequency dependent rates. Analysis based on circuit models of changes in R and X during the short contraction pulses showed that the extra cellular fluid resistance increased by 3.9 +/- 1.4 %, while the capacitance increased by 5.6 +/- 2 %. For long contraction pulses at very low frequencies: (1) there was practically no change in R during contraction, which implies that these changes are due to cellular membrane or intracellular effects with the extra cellular water component not participating, and (2) in post contraction stage there were no morphological changes which means that drifts in R can only be due to physiological changes. Following Shiffman et al. (2003) we measured impedance changes of R and X during a triangular shaped pulse of force generated via isometric forearm muscle contraction at 50 kHz. We measured these changes in 3-100 kHz frequency range for a stair case pulse of forces and the results showed that they are frequency

  10. Analytic Modeling, Simulation and Interpretation of Broadband Beam Coupling Impedance Bench Measurements

    CERN Document Server

    Niedermayer, Uwe; Boine-Frankenheim, Oliver

    2014-01-01

    In the first part of the paper a generalized theoretical approach towards beam coupling impedances and stretched-wire measurements is introduced. Applied to a circular symmetric setup, this approach allows to estimate the systematic measurement error due to the presence of the wire. Further, the interaction of the beam or the TEM wave, respectively, with dispersive material such as ferrite is discussed. The dependence of the obtained impedances on the relativistic velocity $\\beta$ is investigated and found as material property dependent. The conversion formulas for the TEM scattering parameters from measurements to impedances are compared with each other and the analytical impedance solution. In the second part of the paper the measurements are compared to numerical simulations of wakefields and scattering parameters. In practice, the measurements have been performed for the circularly symmetric example setup. The optimization of the measurement process is discussed. The paper concludes with a summary of syst...

  11. Skin-electrode impedance measurement during ECG acquisition: method’s validation

    Science.gov (United States)

    Casal, Leonardo; La Mura, Guillermo

    2016-04-01

    Skm-electrode impedance measurement can provide valuable information prior. dunng and post electrocardiographic (ECG) or electroencephalographs (EEG) acquisitions. In this work we validate a method for skm-electrode impedance measurement using test circuits with known resistance and capacitor values, at different frequencies for injected excitation current. Finally the method is successfully used for impedance measurement during ECG acquisition on a subject usmg 125 Hz and 6 nA square wave excitation signal at instrumentation amplifier mput. The method can be used for many electrodes configuration.

  12. Coupling impedance of an in-vacuum undulator. Measurement, simulation, and analytical estimation

    Energy Technology Data Exchange (ETDEWEB)

    Simaluk, Victor [Science and Technology Facilities Council (STFC), Harwell Campus, Oxford (United Kingdom). Diamond Light Source, Ltd.; Blednykh, Alexei [Brookhaven National Lab. (BNL), Upton, NY (United States); Fielder, Richard [Science and Technology Facilities Council (STFC), Harwell Campus, Oxford (United Kingdom). Diamond Light Source, Ltd.; Rehm, Guenther [Science and Technology Facilities Council (STFC), Harwell Campus, Oxford (United Kingdom). Diamond Light Source, Ltd.; Bartolini, Riccardo [Science and Technology Facilities Council (STFC), Harwell Campus, Oxford (United Kingdom). Diamond Light Source, Ltd.; Univ. of Oxford (United Kingdom)

    2014-07-25

    One of the important issues of the in-vacuum undulator design is the coupling impedance of the vacuum chamber, which includes tapered transitions with variable gap size. In order to get complete and reliable information on the impedance, analytical estimate, numerical simulations and beam-based measurements have been performed at Diamond Light Source, a forthcoming upgrade of which includes introducing additional insertion device (ID) straights. Moreover, the impedance of an already existing ID vessel geometrically similar to the new one has been measured using the orbit bump method. The measurement results in comparison with analytical estimations and numerical simulations are discussed in this paper.

  13. Coupling impedance of an in-vacuum undulator: Measurement, simulation, and analytical estimation

    Science.gov (United States)

    Smaluk, Victor; Fielder, Richard; Blednykh, Alexei; Rehm, Guenther; Bartolini, Riccardo

    2014-07-01

    One of the important issues of the in-vacuum undulator design is the coupling impedance of the vacuum chamber, which includes tapered transitions with variable gap size. To get complete and reliable information on the impedance, analytical estimate, numerical simulations and beam-based measurements have been performed at Diamond Light Source, a forthcoming upgrade of which includes introducing additional insertion device (ID) straights. The impedance of an already existing ID vessel geometrically similar to the new one has been measured using the orbit bump method. The measurement results in comparison with analytical estimations and numerical simulations are discussed in this paper.

  14. Coupling impedance of an in-vacuum undulator: Measurement, simulation, and analytical estimation

    Directory of Open Access Journals (Sweden)

    Victor Smaluk

    2014-07-01

    Full Text Available One of the important issues of the in-vacuum undulator design is the coupling impedance of the vacuum chamber, which includes tapered transitions with variable gap size. To get complete and reliable information on the impedance, analytical estimate, numerical simulations and beam-based measurements have been performed at Diamond Light Source, a forthcoming upgrade of which includes introducing additional insertion device (ID straights. The impedance of an already existing ID vessel geometrically similar to the new one has been measured using the orbit bump method. The measurement results in comparison with analytical estimations and numerical simulations are discussed in this paper.

  15. Impedance Measurements of the Extraction Kicker System for the Rapid Cycling Synchrotron of China Spallation Neutron Source

    CERN Document Server

    Huang, Liangsheng; Liu, Yudong; Li, Yong; Liu, Renhong; Xiao, Ouzheng

    2015-01-01

    The fast extraction kicker system is one of the most important accelerator components, whose inner structure will be the main source of the impedance in the RCS. It is necessary to understand the kicker impedance before its installation into the tunnel. The conventional and improved wire methods are employed for the benchmarking impedance measurement results. The simulation and measurements confirm that the window-frame ferrite geometry and the end plate are the important structures causing the coupling impedance. The total impedance of the eight modules systems is determined by the scaling law from the measurement and the impedance measurement of the kicker system is summarized.

  16. Microelectrical Impedance Spectroscopy for the Differentiation between Normal and Cancerous Human Urothelial Cell Lines: Real-Time Electrical Impedance Measurement at an Optimal Frequency

    Directory of Open Access Journals (Sweden)

    Yangkyu Park

    2016-01-01

    Full Text Available Purpose. To distinguish between normal (SV-HUC-1 and cancerous (TCCSUP human urothelial cell lines using microelectrical impedance spectroscopy (μEIS. Materials and Methods. Two types of μEIS devices were designed and used in combination to measure the impedance of SV-HUC-1 and TCCSUP cells flowing through the channels of the devices. The first device (μEIS-OF was designed to determine the optimal frequency at which the impedance of two cell lines is most distinguishable. The μEIS-OF trapped the flowing cells and measured their impedance at a frequency ranging from 5 kHz to 1 MHz. The second device (μEIS-RT was designed for real-time impedance measurement of the cells at the optimal frequency. The impedance was measured instantaneously as the cells passed the sensing electrodes of μEIS-RT. Results. The optimal frequency, which maximized the average difference of the amplitude and phase angle between the two cell lines (p<0.001, was determined to be 119 kHz. The real-time impedance of the cell lines was measured at 119 kHz; the two cell lines differed significantly in terms of amplitude and phase angle (p<0.001. Conclusion. The μEIS-RT can discriminate SV-HUC-1 and TCCSUP cells by measuring the impedance at the optimal frequency determined by the μEIS-OF.

  17. High-Input Impedance Voltage-Mode Multifunction Filter with Four Grounded Components and Only Two Plus-Type DDCCs

    Directory of Open Access Journals (Sweden)

    Hua-Pin Chen

    2010-01-01

    Full Text Available This paper introduces a novel voltage-mode multifunction biquadratic filter with single input and four outputs using two plus-type differential difference current conveyors (DDCCs and four grounded passive components. The filter can realize inverting highpass, inverting bandpass, noninverting lowpass, and noninverting bandpass filter responses, simultaneously. It still maintains the following advantages: (i using grounded capacitors attractive for integration and absorbing shunt parasitic capacitance, (ii using grounded resistors at all X terminals of DDCCs suitable for the variations of filter parameters and absorbing series parasitic resistances at all X terminals of DDCCs, (iii high-input impedance good for cascadability, (iv no need to change the filter topology, (v no need to component-matching conditions, (vi low active and passive sensitivity performances, and (vii simpler configuration due to the use of plus-type DDCCs only. HSPICE and MATLAB simulations results are provided to demonstrate the theoretical analysis.

  18. Ambulatory measurement of ground reaction forces

    NARCIS (Netherlands)

    Veltink, Petrus H.; Liedtke, C.B.; Droog, Adriaan; van der Kooij, Herman

    2005-01-01

    The measurement of ground reaction forces is important in the biomechanical analysis of gait and other motor activities. Many applications require full ambulatory measurement of these forces, but this is not supported by current measurement systems. We propose the use of two six-degrees-of-freedom f

  19. Measurements of Electric Performance and Impedance of a 75 Ah NMC Lithium Battery Module

    DEFF Research Database (Denmark)

    Jensen, Søren Højgaard; Engelbrecht, Kurt

    2012-01-01

    Detailed characterization of battery modules is necessary to construct reliable models that incorporate performance related aspects of the modules such as thermodynamics, electrochemical reaction kinetics and degradation mechanisms. Charge-discharge curves, temperature and battery impedance...... measurements can provide information about these aspects. Charge-discharge curves can be used to measure the battery open circuit voltage and the internal resistance. Temperature measurements provide information about the thermodynamic reactions and impedance spectra yield detailed information about...... the reaction kinetics. In this paper we present the measurement methods used to examine the internal resistance, the capacity and the impedance of a 75 Ah NMC battery module. In order to measure the impedance of the battery module and of the individual cells in the module, we combine the single sine technique...

  20. Electrical impedance measured changes in thoracic fluid content during thoracentesis

    DEFF Research Database (Denmark)

    Petersen, J R; Jensen, B V; Drabaek, H;

    1994-01-01

    of each 500 ml, and at the end of the thoracentesis. We found a close linear correlation (r = 0.97) between changes in Z0 and the volume of aspirated pleural effusion (y = 0.415.x+0.093). The variability of the estimated thoracic fluid volumes was analysed with a plot of the residuals from the regression...... line, and we found that changes in thoracic fluid volume estimated by impedance technique would be within +/- 302 ml (= 2 SD). However, the absolute value of Z0 before thoracentesis could not differentiate the group of patients with pleural effusion from normal subjects (n = 28)....

  1. Noninvasive surface measurement of corrosion impedance of reinforcing bar in concrete - part 1: experimental results

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, Jieying; Monteiro, Paulo J.M.; Morrison, H. Frank

    2000-11-01

    The corrosion state of a reinforcing steel bar in concrete can be characterized by the electrical impedance of the interface between the steel bar and the concrete. The experimental part of this study, has shown that changes in the interfacial impedance that are diagnostic of the rate and extent of the corrosion can be measured indirectly with an array of current and voltage electrodes on the concrete surface. The measured impedance, however depends on the electrical resistivity of the concrete, and the depth and diameter of the steel reinforcing bar as well as the interfacial properties. To relate the measured impedance directly to the interfacial properties, a closed-form solution to the governing Poisson's equation was developed and programmed for the potentials from arbitrary, current sources in the vicinity of the reinforcing bar. The solution uses an impedance boundary, condition for the complex impedance at the steel-concrete interface. The response of an arbitrary corrosion state can be simulated in this model by embedding the appropriate complex, frequency-dependent impedance at the interface and computing the voltage/current response that would be measured for an arbitrary placement of electrodes on the concrete surface. To simulate the experimental findings, this paper presents the modeling results by various interfacial impedances but constant concrete resistivity and constant geometry of the steel reinforcing bar This simulation confirms that important parameters of the interfacial impedance controlling corrosion kinetics such as polarization resistance and double layer capacitance are clearly, observed in the measured surface data. [References: 10

  2. Noninvasive surface measurement of corrosion impedance of reinforcing bar in concrete - part 2: forward modeling

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, Jieying; Monteiro, Paulo J. M.; Morrison, H. Frank

    2002-01-02

    The corrosion state of a reinforcing steel bar in concrete can be characterized by the electrical impedance of the interface between the steel bar and the concrete. The experimental part of this study, has shown that changes in the interfacial impedance that are diagnostic of the rate and extent of the corrosion can be measured indirectly with an array of current and voltage electrodes on the concrete surface. The measured impedance, however depends on the electrical resistivity of the concrete, and the depth and diameter of the steel reinforcing bar as well as the interfacial properties. To relate the measured impedance directly to the interfacial properties, a closed-form solution to the governing Poisson's equation was developed and programmed for the potentials from arbitrary, current sources in the vicinity of the reinforcing bar. The solution uses an impedance boundary, condition for the complex impedance at the steel-concrete interface. The response of an arbitrary corrosion state can be simulated in this model by embedding the appropriate complex, frequency-dependent impedance at the interface and computing the voltage/current response that would be measured for an arbitrary placement of electrodes on the concrete surface. To simulate the experimental findings, this paper presents the modeling results by various interfacial impedances but constant concrete resistivity and constant geometry of the steel reinforcing bar. This simulation confirms that important parameters of the interfacial impedance controlling corrosion kinetics such as polarization resistance and double layer capacitance are clearly, observed in the measured surface data. [References: 10

  3. Structure and properties of loaded silica contacts during pressure solution: impedance spectroscopy measurements under hydrothermal conditions

    NARCIS (Netherlands)

    Noort, R. van; Spiers, C.J.; Peach, C.J.

    2011-01-01

    In order to investigate directly the structure and properties of grain boundaries in silicatematerials undergoing pressure solution, in situmeasurements of these properties are required. We report electrical impedance spectroscopy measurements, performed, under hydrothermal conditions,

  4. Evaluation of electrical impedance ratio measurements in accuracy of electronic apex locators

    Directory of Open Access Journals (Sweden)

    Pil-Jong Kim

    2015-05-01

    Full Text Available Objectives The aim of this paper was evaluating the ratios of electrical impedance measurements reported in previous studies through a correlation analysis in order to explicit it as the contributing factor to the accuracy of electronic apex locator (EAL. Materials and Methods The literature regarding electrical property measurements of EALs was screened using Medline and Embase. All data acquired were plotted to identify correlations between impedance and log-scaled frequency. The accuracy of the impedance ratio method used to detect the apical constriction (APC in most EALs was evaluated using linear ramp function fitting. Changes of impedance ratios for various frequencies were evaluated for a variety of file positions. Results Among the ten papers selected in the search process, the first-order equations between log-scaled frequency and impedance were in the negative direction. When the model for the ratios was assumed to be a linear ramp function, the ratio values decreased if the file went deeper and the average ratio values of the left and right horizontal zones were significantly different in 8 out of 9 studies. The APC was located within the interval of linear relation between the left and right horizontal zones of the linear ramp model. Conclusions Using the ratio method, the APC was located within a linear interval. Therefore, using the impedance ratio between electrical impedance measurements at different frequencies was a robust method for detection of the APC.

  5. Measuring Electrolyte Impedance and Noise Simultaneously by Triangular Waveform Voltage and Principal Component Analysis.

    Science.gov (United States)

    Xu, Shanzhi; Wang, Peng; Dong, Yonggui

    2016-04-22

    In order to measure the impedance variation process in electrolyte solutions, a method of triangular waveform voltage excitation is investigated together with principal component analysis (PCA). Using triangular waveform voltage as the excitation signal, the response current during one duty cycle is sampled to construct a measurement vector. The measurement matrix is then constructed by the measurement vectors obtained from different measurements. After being processed by PCA, the changing information of solution impedance is contained in the loading vectors while the response current and noise information is contained in the score vectors. The measurement results of impedance variation by the proposed signal processing method are independent of the equivalent impedance model. The noise-induced problems encountered during equivalent impedance calculation are therefore avoided, and the real-time variation information of noise in the electrode-electrolyte interface can be extracted at the same time. Planar-interdigitated electrodes are experimentally tested for monitoring the KCl concentration variation process. Experimental results indicate that the measured impedance variation curve reflects the changing process of solution conductivity, and the amplitude distribution of the noise during one duty cycle can be utilized to analyze the contact conditions of the electrode and electrolyte interface.

  6. Measuring Electrolyte Impedance and Noise Simultaneously by Triangular Waveform Voltage and Principal Component Analysis

    Directory of Open Access Journals (Sweden)

    Shanzhi Xu

    2016-04-01

    Full Text Available In order to measure the impedance variation process in electrolyte solutions, a method of triangular waveform voltage excitation is investigated together with principal component analysis (PCA. Using triangular waveform voltage as the excitation signal, the response current during one duty cycle is sampled to construct a measurement vector. The measurement matrix is then constructed by the measurement vectors obtained from different measurements. After being processed by PCA, the changing information of solution impedance is contained in the loading vectors while the response current and noise information is contained in the score vectors. The measurement results of impedance variation by the proposed signal processing method are independent of the equivalent impedance model. The noise-induced problems encountered during equivalent impedance calculation are therefore avoided, and the real-time variation information of noise in the electrode-electrolyte interface can be extracted at the same time. Planar-interdigitated electrodes are experimentally tested for monitoring the KCl concentration variation process. Experimental results indicate that the measured impedance variation curve reflects the changing process of solution conductivity, and the amplitude distribution of the noise during one duty cycle can be utilized to analyze the contact conditions of the electrode and electrolyte interface.

  7. Rapid Impedance Spectrum Measurements for Onboard State-of-Health Applications

    Energy Technology Data Exchange (ETDEWEB)

    Jon P. Christophersen; John L. Morrison; Chinh D. Ho

    2012-06-01

    Rapid impedance measurements can provide a useful online tool for improved state-of-health estimation. A validation study has been initiated at the Idaho National Laboratory for a rapid impedance technique known as Harmonic Compensated Synchronous Detection. This technique enables capturing the impedance spectra over a broad frequency range within about ten seconds. Commercially available lithium-ion cells are being calendar-life aged at 50°C with reference performance tests at 30°C every 32.5 days to gauge degradation The cells have completed the first set of reference performance tests and preliminary results are presented. The spectra change as a function of temperature and depth-of-discharge condition, as expected. The data indicate that the rapid impedance measurement technique is a benign measurement tool that can be successfully used to gauge changes in the corresponding pulse resistance.

  8. Circuits and methods for impedance determination using active measurement cancelation

    Energy Technology Data Exchange (ETDEWEB)

    Jamison, David K.

    2016-12-13

    A delta signal and opposite delta signal are generated such that a sum of the two signals is substantially zero. The delta signal is applied across a first set of electrochemical cells. The opposite delta signal is applied across a second set of electrochemical cells series connected to the first set. A first held voltage is established as the voltage across the first set. A second held voltage is established as the voltage across the second set. A first delta signal is added to the first held voltage and applied to the first set. A second delta signal is added to the second held voltage and applied to the second set. The current responses due to the added delta voltages travel only into the set associated with its delta voltage. The delta voltages and the current responses are used to calculate the impedances of their associated cells.

  9. A novel method for real-time skin impedance measurement during radiofrequency skin tightening treatments.

    Science.gov (United States)

    Harth, Yoram; Lischinsky, Daniel

    2011-03-01

    The thermal effects of monopolar and bipolar radiofrequency (RF) have been proven to be beneficial in skin tightening. Nevertheless, these effects were frequently partial or unpredictable because of the uncontrolled nature of monopolar or unipolar RF and the superficial nature of energy flow for bipolar or tripolar configurations. One of the hypotheses for lack or predictability of efficacy of the first-generation RF therapy skin tightening systems is lack of adaptation of delivered power to differences in individual skin impedance. A novel multisource phase-controlled system was used (1 MHz, power range 0-65 W) for treatment and real-time skin impedance measurements in 24 patients (EndyMed PRO™; EndyMed, Cesarea, Israel). This system allows continuous real-time measurement of skin impedance delivering constant energy to the patient skin independent of changes in its impedance. More than 6000 unique skin impedance measurements on 22 patients showed an average session impedance range was 215-584 Ohm with an average of 369 Ohm (standard deviation of 49 Ohm). Analyzing individual pulses (total of 600 readings) showed a significant decrease in impedance during the pulse. These findings validate the expected differences in skin impedance between individual patients and in the same patients during the treatment pulse. Clinical study on 30 patients with facial skin aging using the device has shown high predictability of efficacy (86.7% of patients had good results or better at 3 months' follow-up [decrease of 2 or more grades in Fitzpatrick's wrinkle scale]). The real-time customization of energy according to skin impedance allows a significantly more accurate and safe method of nonablative skin tightening with more consistent and predictable results. © 2011 Wiley Periodicals, Inc.

  10. Influence of measurement procedure on quality of impedance spectra on lead-acid batteries

    Science.gov (United States)

    Budde-Meiwes, Heide; Kowal, Julia; Sauer, Dirk Uwe; Karden, Eckhard

    Many battery simulation models, but also electrochemical interpretations are based on impedance spectroscopy. However, the impedance of a battery is influenced by various factors, e.g. in the case of a lead-acid battery: state of charge (SOC), charging or discharging, superimposed dc current, short-term history or homogeneity of the electrolyte. This paper analyses the impact of those factors on impedance spectra of lead-acid batteries. The results show that very detailed information about the conditions during the measurement is crucial for the correct interpretation of a spectrum.

  11. A new contactless impedance sensor for void fraction measurement of gas-liquid two-phase flow

    Science.gov (United States)

    Ji, Haifeng; Chang, Ya; Huang, Zhiyao; Wang, Baoliang; Li, Haiqing

    2016-12-01

    With impedance elimination principle and phase sensitive demodulation (PSD) technique, this work aims to develop a new contactless impedance sensor, which is suitable for the void fraction measurement of gas-liquid two-phase flow. The impedance elimination principle is used to overcome the unfavorable influences of the coupling capacitances, i.e. the capacitive reactances of the coupling capacitances are eliminated by the inductive reactance of an introduced inductor. PSD technique is used to implement the impedance measurement. Unlike the conventional conductance/impedance sensors which use the equivalent conductance (the real part of the impedance) or the amplitude of the impedance of gas-liquid two-phase flow, the new contactless impedance sensor makes full use of the total impedance information of gas-liquid two-phase flow (including the amplitude, the real part and the imaginary part of the impedance, especially the imaginary part) to implement the void fraction measurement. As a preliminary study, to verify the effectiveness of the new contactless impedance sensor, two prototypes (with different inner diameters of 17.0 mm and 22.0 mm) are developed and experiments are carried out. Two typical flow patterns (bubble flow and stratified flow) of gas-liquid two-phase flow are investigated. The experimental results show that the new contactless impedance sensor is successful and effective. Compared with the conventional conductance/impedance sensors, the new contactless impedance sensor can avoid polarization effect and electrochemical erosion effect. The total impedance information is used and the void fraction measurement performance of the new sensor is satisfactory. The experimental results also indicate that the imaginary part of the impedance of gas-liquid two-phase flow is very useful for the void fraction measurement. Making full use of the total impedance information of gas-liquid two-phase flow can effectively improve the void fraction measurement

  12. Experimental investigation of microwave interaction with magnetoplasma in miniature multipolar configuration using impedance measurements

    Energy Technology Data Exchange (ETDEWEB)

    Dey, Indranuj, E-mail: indranuj@aees.kyushu-u.ac.jp; Toyoda, Yuji; Yamamoto, Naoji; Nakashima, Hideki [Department of Advanced Energy Engineering Science, Kyushu University, Kasuga 816-8580 (Japan)

    2014-09-15

    A miniature microwave plasma source employing both radial and axial magnetic fields for plasma confinement has been developed for micro-propulsion applications. Plasma is initiated by launching microwaves via a short monopole antenna to circumvent geometrical cutoff limitations. The amplitude and phase of the forward and reflected microwave power is measured to obtain the complex reflection coefficient from which the equivalent impedance of the plasma source is determined. Effect of critical plasma density condition is reflected in the measurements and provides insight into the working of the miniature plasma source. A basic impedance calculation model is developed to help in understanding the experimental observations. From experiment and theory, it is seen that the equivalent impedance magnitude is controlled by the coaxial discharge boundary conditions, and the phase is influenced primarily by the plasma immersed antenna impedance.

  13. Sensing fluid viscosity and density through mechanical impedance measurement using a whisker transducer

    Science.gov (United States)

    Ju, Feng; Ling, Shih-Fu

    2013-05-01

    This paper presents a new technique for fluid viscosity and density sensing through measuring the mechanical impedance of the fluid load applied on a sphere. A piezoelectric whisker transducer (WT) is proposed which acts simultaneously as both the actuator to excite the sphere tip to oscillate in the fluid and the sensor to measure the force, velocity and mechanical impedance. The relationship between mechanical impedance of the fluid load and electrical impedance of the WT is derived based on a transduction matrix model which characterizes the electro-mechanical transduction process of the WT in both directions. The mechanical impedance is further related to the fluid viscosity and density using a theoretical model. The establishment of this fluid-mechanical-electrical relationship allows the WT to extract the fluid viscosity and density conveniently and accurately just from its electrical impedance. Experimental studies are carried out to calibrate the WT and test its performance using glycerol-water mixtures. It is concluded that the WT is capable of providing results comparable to those of standard viscometers within a wide measurement range due to its low working frequency and large vibration amplitude. Its unique self-actuation-and-sensing feature makes it a suitable solution for online fluid sensing.

  14. A new measuring and identification approach for time-varying bioimpedance using multisine electrical impedance spectroscopy.

    Science.gov (United States)

    Sanchez, B; Louarroudi, E; Jorge, E; Cinca, J; Bragos, R; Pintelon, R

    2013-03-01

    The bioimpedance measurement/identification of time-varying biological systems Z(ω, t) by means of electrical impedance spectroscopy (EIS) is still a challenge today. This paper presents a novel measurement and identification approach, the so-called parametric-in-time approach, valid for time-varying (bio-)impedance systems with a (quasi) periodic character. The technique is based on multisine EIS. Contrary to the widely used nonparametric-in-time strategy, the (bio-)impedance Z(ω, t) is assumed to be time-variant during the measurement interval. Therefore, time-varying spectral analysis tools are required. This new parametric-in-time measuring/identification technique has experimentally been validated through three independent sets of in situ measurements of in vivo myocardial impedance. We show that the time-varying myocardial impedance Z(ω, t) is dominantly periodically time varying (PTV), denoted as ZPTV(ω, t). From the temporal analysis of ZPTV(ω, t), we demonstrate that it is possible to decompose ZPTV(ω, t) into a(n) (in)finite sum of fundamental (bio-)impedance spectra, the so-called harmonic impedance spectra (HIS) Zk(ω)s with [Formula: see text]. This is similar to the well-known Fourier series of a periodic signal, but now understood at the level of a periodic system's frequency response. The HIS Zk(ω)s for [Formula: see text] actually summarize in the bi-frequency (ω, k) domain all the temporal in-cycle information about the periodic changes of Z(ω, t). For the particular case k = 0 (i.e. on the ω-axis), Z0(ω) reflects the mean in-cycle behavior of the time-varying bioimpedance. Finally, the HIS Zk(ω)s are directly identified from noisy current and voltage myocardium measurements at the multisine measurement frequencies (i.e. nonparametric-in-frequency).

  15. Evaluation of a novel correction procedure to remove electrode impedance effects from broadband SIP measurements

    Science.gov (United States)

    Huisman, Johan Alexander; Zimmermann, Egon; Esser, Odilia; Haegel, Franz-Hubert; Treichel, Andrea; Vereecken, Harry

    2016-12-01

    Broadband spectral induced polarization (SIP) measurements of the complex electrical resistivity can be affected by the contact impedance of the potential electrodes above 100 Hz. In this study, we present a correction procedure to remove electrode impedance effects from SIP measurements to improve the accuracy of broadband complex electrical resistivity measurements. The first step in this correction procedure is to estimate the electrode impedance using a measurement with reversed current and potential electrodes. In a second step, this estimated electrode impedance is used to correct SIP measurements based on a simplified electrical model of the SIP measurement system. We evaluated this new correction procedure using SIP measurements on water because of the well-defined dielectric properties. It was found that the difference between the corrected and expected phase of the complex electrical resistivity of water was below 0.1 mrad at 1 kHz for a wide range of electrode impedances. In addition, SIP measurements on a saturated unconsolidated sediment sample with two types of potential electrodes showed that the measured phase of the electrical resistivity was very similar (difference resistivity was improved for frequencies up to 1 kHz, but errors remained for higher frequencies due to the approximate nature of the electrode impedance estimates and some remaining unknown parasitic capacitances that led to current leakage. It was concluded that the proposed correction procedure for SIP measurements improved the accuracy of the phase measurements by an order of magnitude in the kHz frequency range. Further improvement of this accuracy requires a method to accurately estimate parasitic capacitances in situ.

  16. Positive phase error from parallel conductance in tetrapolar bio-impedance measurements and its compensation

    Directory of Open Access Journals (Sweden)

    Ivan M Roitt

    2010-01-01

    Full Text Available Bioimpedance measurements are of great use and can provide considerable insight into biological processes.  However, there are a number of possible sources of measurement error that must be considered.  The most dominant source of error is found in bipolar measurements where electrode polarisation effects are superimposed on the true impedance of the sample.  Even with the tetrapolar approach that is commonly used to circumvent this issue, other errors can persist. Here we characterise the positive phase and rise in impedance magnitude with frequency that can result from the presence of any parallel conductive pathways in the measurement set-up.  It is shown that fitting experimental data to an equivalent electrical circuit model allows for accurate determination of the true sample impedance as validated through finite element modelling (FEM of the measurement chamber.  Finally, the model is used to extract dispersion information from cell cultures to characterise their growth.

  17. Optimally tuned resonant negative capacitance for piezoelectric shunt damping based on measured electromechanical impedance

    Science.gov (United States)

    Salloum, Rogério; Heuss, Oliver; Götz, Benedict; Mayer, Dirk

    2015-04-01

    In this paper, a new tuning method for shunt damping with a series resistance, inductance and negative capacitance is proposed and its validity is investigated. It is based on the measured electromechanical impedance of a piezoelectric system, which is represented through an equivalent electrical circuit that takes into account the characteristics of the piezoelectric transducer and the host structure. Afterwards, an additional circuit representing the shunt is connected and the Norton equivalent impedance is obtained at the terminals that represent the mechanical mode of interest. During the tuning process, the optimal shunt parameters are found by minimizing the maximum absolute value of the Norton equivalent impedance over a defined frequency range through a numerical optimization. Taking benefit from the analogy between electrical impedance and mechanical admittance, the minimization of different mechanical responses (displacement, velocity or acceleration) is also proposed and the different optimum shunt parameters obtained are compared. In view of real technical applications, this method allows the integration of a real negative capacitance circuit, i.e., a negative impedance converter, rather than an ideal component. It is thus possible to use the impedance of this circuit and optimize the individual component values. Since this method is based on one simple measurement, it can be applied to arbitrary structures without the need of complex dynamic tests or expensive finite elements calculations. Finally, an experimental analysis is carried out in order to compare the damping performance of the proposed method and the conventional analytical method that minimizes a mechanical frequency response function.

  18. Skin Impedance Measurements for Acupuncture Research: Development of a Continuous Recording System

    Directory of Open Access Journals (Sweden)

    Agatha P. Colbert

    2008-01-01

    Full Text Available Skin impedance at acupuncture points (APs has been used as a diagnostic/therapeutic aid for more than 50 years. Currently, researchers are evaluating the electrophysiologic properties of APs as a possible means of understanding acupuncture's mechanism. To comprehensively assess the diagnostic, therapeutic and mechanistic implications of acupuncture point skin impedance, a device capable of reliably recording impedances from 100 kΩ to 50 MΩ at multiple APs over extended time periods is needed. This article describes design considerations, development and testing of a single channel skin impedance system (hardware, control software and customized electrodes. The system was tested for accuracy against known resistors and capacitors. Two electrodes (the AMI and the ORI were compared for reliability of recording over 30 min. Two APs (LU 9 and PC 6 and a nearby non-AP site were measured simultaneously in four individuals for 60 min. Our measurement system performed accurately (within 5% against known resistors (580 kΩ–10 MΩ and capacitors (10 nF–150 nF. Both the AMI electrode and the modified ORI electrode recorded skin impedance reliably on the volar surface of the forearm (r = 0.87 and r = 0.79, respectively. In four of four volunteers tested, skin impedance at LU 9 was less than at the nearby non-AP site. In three of four volunteers skin impedance was less at PC 6 than at the nearby non-AP site. We conclude that our system is a suitable device upon which we can develop a fully automated multi-channel device capable of recording skin impedance at multiple APs simultaneously over 24 h.

  19. Skin Impedance Measurements for Acupuncture Research: Development of a Continuous Recording System

    Science.gov (United States)

    Yun, Jinkook; Larsen, Adrian; Edinger, Tracy; Gregory, William L.; Thong, Tran

    2008-01-01

    Skin impedance at acupuncture points (APs) has been used as a diagnostic/therapeutic aid for more than 50 years. Currently, researchers are evaluating the electrophysiologic properties of APs as a possible means of understanding acupuncture's mechanism. To comprehensively assess the diagnostic, therapeutic and mechanistic implications of acupuncture point skin impedance, a device capable of reliably recording impedances from 100 kΩ to 50 MΩ at multiple APs over extended time periods is needed. This article describes design considerations, development and testing of a single channel skin impedance system (hardware, control software and customized electrodes). The system was tested for accuracy against known resistors and capacitors. Two electrodes (the AMI and the ORI) were compared for reliability of recording over 30 min. Two APs (LU 9 and PC 6) and a nearby non-AP site were measured simultaneously in four individuals for 60 min. Our measurement system performed accurately (within 5%) against known resistors (580 kΩ–10 MΩ) and capacitors (10 nF–150 nF). Both the AMI electrode and the modified ORI electrode recorded skin impedance reliably on the volar surface of the forearm (r = 0.87 and r = 0.79, respectively). In four of four volunteers tested, skin impedance at LU 9 was less than at the nearby non-AP site. In three of four volunteers skin impedance was less at PC 6 than at the nearby non-AP site. We conclude that our system is a suitable device upon which we can develop a fully automated multi-channel device capable of recording skin impedance at multiple APs simultaneously over 24 h. PMID:18955218

  20. Particle trapping and impedance measurement using bilayer electrodes integrated with microcavity structure

    Science.gov (United States)

    Chen, Guan-Ting; Liu, Chia-Feng; Jang, Ling-Sheng; Li, Shun-Lai; Wang, Min-Haw

    2017-03-01

    Traditional planar electrodes for single-particle impedance measurement have difficulty in trapping and positioning particles. This paper proposes a microfluidic device for single-particle trapping and impedance measurement with a microcavity configuration. A carbon dioxide (CO2) laser technique was used to fabricate the microcavity structure, which can capture 15 µm diameter particles without requiring additional trapping structures. The measurement electrodes on both sides of the microcavity were fabricated using electroplating and deposition techniques. The advantages of the microcavity structure and electrodes are discussed. The bottom electrode spreads into the microcavity to increase measurement sensitivity and shrink the exit aperture to around 10 µm for particle trapping. The experimental results show that the device successfully captured particles and distinguished the impedance of a particle from that of phosphate-buffered saline solution.

  1. Automatic on-line analyser of microbial growth using simultaneous measurements of impedance and turbidity.

    Science.gov (United States)

    Madrid, R E; Felice, C J; Valentinuzzi, M E

    1999-11-01

    An apparatus for the measurement of bacterial growth is described. The instrument applies alternate adequate sequential currents of two different frequencies through a pair of electrodes immersed in a cultured medium. It monitors, detects and quantifies the growth of micro-organisms based on the measurement of the impedance across the two electrodes and, simultaneously, it measures the variation in the medium turbidity. The medium conductivity and the interface electrode impedance changes can be extracted from the measured impedance. The variations in turbidity can be calibrated in absorbance or optical density units. Moreover, all these parameters are also proportional to bacterial proliferation. The computer-controlled apparatus processes and displays the parameters on a monitor showing bulk resistance, electrode impedance and turbidity changes as time course events. The equipment can detect aerobic or anaerobic micro-organisms and permits the operator simultaneously to assess impedance and turbidity, or it can produce each parameter as a separate event. Time growth curves of different micro-organisms are presented in the results.

  2. New equivalent-electrical circuit model and a practical measurement method for human body impedance.

    Science.gov (United States)

    Chinen, Koyu; Kinjo, Ichiko; Zamami, Aki; Irei, Kotoyo; Nagayama, Kanako

    2015-01-01

    Human body impedance analysis is an effective tool to extract electrical information from tissues in the human body. This paper presents a new measurement method of impedance using armpit electrode and a new equivalent circuit model for the human body. The lowest impedance was measured by using an LCR meter and six electrodes including armpit electrodes. The electrical equivalent circuit model for the cell consists of resistance R and capacitance C. The R represents electrical resistance of the liquid of the inside and outside of the cell, and the C represents high frequency conductance of the cell membrane. We propose an equivalent circuit model which consists of five parallel high frequency-passing CR circuits. The proposed equivalent circuit represents alpha distribution in the impedance measured at a lower frequency range due to ion current of the outside of the cell, and beta distribution at a high frequency range due to the cell membrane and the liquid inside cell. The calculated values by using the proposed equivalent circuit model were consistent with the measured values for the human body impedance.

  3. 7 CFR 1755.402 - Ground resistance measurements.

    Science.gov (United States)

    2010-01-01

    ... ground resistance of electronic equipment such as span line repeaters, carrier terminal equipment... Protection Grounding Fundamentals,” for a comprehensive discussion of ground resistance measurements. (d... electronic equipment, the ground resistance shall not exceed 25 ohms. Where the measured ground...

  4. An analysis of electrical impedance measurements applied for plant N status estimation in lettuce (Lactuca sativa).

    Science.gov (United States)

    Muñoz-Huerta, Rafael F; Ortiz-Melendez, Antonio de J; Guevara-Gonzalez, Ramon G; Torres-Pacheco, Irineo; Herrera-Ruiz, Gilberto; Contreras-Medina, Luis M; Prado-Olivarez, Juan; Ocampo-Velazquez, Rosalia V

    2014-06-27

    Nitrogen plays a key role in crop yields. Hence, farmers may apply excessive N fertilizers to crop fields, inducing environmental pollution. Crop N monitoring methods have been developed to improve N fertilizer management, most of them based on leaf or canopy optical-property measurements. However, sensitivity to environmental interference remains an important drawback. Electrical impedance has been applied to determine the physiological and nutritional status of plant tissue, but no studies related to plant-N contents are reported. The objective of this article is to analyze how the electrical impedance response of plants is affected by their N status. Four sets of lettuce (Lactuca sativa L.) with a different N-source concentrations per set were used. Total nitrogen and electrical impedance spectra (in a 1 to 100 kHz frequency range) were measured five times per set, three times every other day. Minimum phase angles of impedance spectra were detected and analyzed, together with the frequency value in which they occurred, and their magnitude at that frequency. High and positive correlation was observed between plant N content and frequency values at minimum phase angle with no significant variations detected between days of measurement. These results suggest that electrical impedance can be sensitive to plant N status.

  5. Time-invariant measurement of time-varying bioimpedance using vector impedance analysis.

    Science.gov (United States)

    Sanchez, B; Louarroudi, E; Pintelon, R

    2015-03-01

    When stepped-sine impedance spectroscopy measurements are carried out on (periodically) time-varying bio-systems, the inherent time-variant (time-periodic) parts are traditionally ignored or mitigated by filtering. The latter, however, lacks theoretical foundation and, in this paper, it is shown that it only works under certain specific conditions. Besides, we propose an alternative method, based on multisine signals, that exploits the non-stationary nature in time-varying bio-systems with a dominant periodic character, such as cardiovascular and respiratory systems, or measurements interfered with by their physiological activities. The novel method extracts the best—in a mean square sense—linear time-invariant (BLTI) impedance approximation ZBLTI(jω) of a periodically time-varying (PTV) impedance ZPTV(jω, t) as well as its time-periodic part. Relying on the geometrical interpretation of the BLTI concept, a new impedance analysis tool, called vector impedance analysis (VIA), is also presented. The theoretical and practical aspects are validated through measurements performed on a PTV dummy circuit and on an in vivo myocardial tissue.

  6. An Analysis of Electrical Impedance Measurements Applied for Plant N Status Estimation in Lettuce (Lactuca sativa

    Directory of Open Access Journals (Sweden)

    Rafael F. Muñoz-Huerta

    2014-06-01

    Full Text Available Nitrogen plays a key role in crop yields. Hence, farmers may apply excessive N fertilizers to crop fields, inducing environmental pollution. Crop N monitoring methods have been developed to improve N fertilizer management, most of them based on leaf or canopy optical-property measurements. However, sensitivity to environmental interference remains an important drawback. Electrical impedance has been applied to determine the physiological and nutritional status of plant tissue, but no studies related to plant-N contents are reported. The objective of this article is to analyze how the electrical impedance response of plants is affected by their N status. Four sets of lettuce (Lactuca sativa L. with a different N-source concentrations per set were used. Total nitrogen and electrical impedance spectra (in a 1 to 100 kHz frequency range were measured five times per set, three times every other day. Minimum phase angles of impedance spectra were detected and analyzed, together with the frequency value in which they occurred, and their magnitude at that frequency. High and positive correlation was observed between plant N content and frequency values at minimum phase angle with no significant variations detected between days of measurement. These results suggest that electrical impedance can be sensitive to plant N status.

  7. Measurement of bio-impedance with a smart needle to confirm percutaneous kidney access.

    Science.gov (United States)

    Hernandez, D J; Sinkov, V A; Roberts, W W; Allaf, M E; Patriciu, A; Jarrett, T W; Kavoussi, L R; Stoianovici, D

    2001-10-01

    The traditional method of percutaneous renal access requires freehand needle placement guided by C-arm fluoroscopy, ultrasonography, or computerized tomography. This approach provides limited objective means for verifying successful access. We developed an impedance based percutaneous Smart Needle system and successfully used it to confirm collecting system access in ex vivo porcine kidneys. The Smart Needle consists of a modified 18 gauge percutaneous access needle with the inner stylet electrically insulated from the outer sheath. Impedance is measured between the exposed stylet tip and sheath using Model 4275 LCR meter (Hewlett-Packard, Sunnyvale, California). An ex vivo porcine kidney was distended by continuous gravity infusion of 100 cm. water saline from a catheter passed through the parenchyma into the collecting system. The Smart Needle was gradually inserted into the kidney to measure depth precisely using a robotic needle placement system, while impedance was measured continuously. The Smart Needle was inserted 4 times in each of 4 kidneys. When the needle penetrated the distended collecting system in 11 of 16 attempts, a characteristic sharp drop in resistivity was noted from 1.9 to 1.1 ohm m. Entry into the collecting system was confirmed by removing the stylet and observing fluid flow from the sheath. This characteristic impedance change was observed only at successful entry into the collecting system. A characteristic sharp drop in impedance signifies successful entry into the collecting system. The Smart Needle system may prove useful for percutaneous kidney access.

  8. Studies of longitudinal profile of electron bunches and impedance measurements at Indus-2 synchrotron radiation source

    Science.gov (United States)

    Garg, Akash Deep; Yadav, S.; Kumar, Mukesh; Shrivastava, B. B.; Karnewar, A. K.; Ojha, A.; Puntambekar, T. A.

    2016-04-01

    Indus-2 is a 3rd generation synchrotron radiation source at the Raja Ramanna Centre for Advanced Technology (RRCAT) in India. We study the longitudinal profile of electrons in Indus-2 by using dual sweep synchroscan streak camera at visible diagnostic beamline. In this paper, the longitudinal profiles of electron bunch are analyzed by filling beam current in a single bunch mode. These studies are carried at injection energy (550 MeV) and at ramped beam energy (2.5 GeV). The effects of the wakefield generated interactions between the circulating electrons and the surrounding vacuum chamber are analyzed in terms of measured effects on longitudinal beam distribution. The impedance of the storage ring is obtained by fitting the solutions of Haissinski equation to the measured bunch lengthening with different impedance models. The impedance of storage ring obtained by a series R+L impedance model indicates a resistance (R) of 1350±125 Ω, an inductance (L) of 180±25 nH and broadband impedance of 2.69 Ω. These results are also compared with the values obtained from measured synchronous phase advancing and scaling laws. These studies are very useful in better understanding and control of the electromagnetic interactions.

  9. LDV measurement of bird ear vibrations to determine inner ear impedance and middle ear power flow

    Science.gov (United States)

    Muyshondt, Pieter G. G.; Pires, Felipe; Dirckx, Joris J. J.

    2016-06-01

    The mechanical behavior of the middle ear structures in birds and mammals is affected by the fluids in the inner ear (IE) that are present behind the oval window. In this study, the aim was to gather knowledge of the acoustic impedance of the IE in the ostrich, to be able to determine the effect on vibrations and power flow in the single-ossicle bird middle ear for future studies. To determine the IE impedance, vibrations of the ossicle were measured for both the quasi-static and acoustic stimulus frequencies. In the acoustic regime, vibrations were measured with a laser Doppler vibrometer and electromagnetic stimulation of the ossicle. The impedance of the inner ear could be determined by means of a simple RLC model in series, which resulted in a stiffness reactance of KIE = 0.20.1012 Pa/m3, an inertial impedance of MIE = 0.652.106 Pa s2/m3, and a resistance of RIE = 1.57.109 Pa s/m. The measured impedance is found to be considerably smaller than what is found for the human IE.

  10. Development of impedance sensors at ORNL: for measurement of two-phase flows. [PWR

    Energy Technology Data Exchange (ETDEWEB)

    Eads, B.G.; Hylton, J.O.

    1979-10-30

    Techniques and equipment have been developed to measure in-vessel local void fraction and velocity in a reflood transient test facility. The two impedance sensors, the flag probe and the string probe, have been tested (prototype sensors) in a variety of air-water and steam-water facilities an in all cases acceptable measurement results were obtained.

  11. Measurements on the SPS 200 MHz Travelling Wave Cavity towards an Impedance Model

    CERN Document Server

    Roggen, Toon; Caspers, Fritz; Vollinger, Christine; CERN. Geneva. ATS Department

    2016-01-01

    This note discusses the contribution of the SPS 200 MHz TWC (Travelling Wave Cavity) to the SPS longitudinal impedance model. The measurement method and setup is briefly explained and a comparison with simulations is discussed for both the fundamental pass band (FPB) as well as the Higher Order Modes (HOMs). In addition a number of improvements to the measurement setup are discussed.

  12. Measurement of absorption with a p-u sound intensity probe in an impedance tube

    DEFF Research Database (Denmark)

    Liu, Yang; Jacobsen, Finn

    2005-01-01

    An alternative method of measuring the normal-incidence sound absorption of a sample of material in an impedance tube is examined. The method is based on measurement of the sound pressure and the normal component of the particle velocity using a "p-u" sound intensity probe. This technique...

  13. UNIVERSAL AUTO-CALIBRATION FOR A RAPID BATTERY IMPEDANCE SPECTRUM MEASUREMENT DEVICE

    Energy Technology Data Exchange (ETDEWEB)

    Jon P. Christophersen; John L. Morrison; William H. Morrison

    2014-03-01

    Electrochemical impedance spectroscopy has been shown to be a valuable tool for diagnostics and prognostics of energy storage devices such as batteries and ultra-capacitors. Although measurements have been typically confined to laboratory environments, rapid impedance spectrum measurement techniques have been developed for on-line, embedded applications as well. The prototype hardware for the rapid technique has been validated using lithium-ion batteries, but issues with calibration had also been identified. A new, universal automatic calibration technique was developed to address the identified issues while also enabling a more simplified approach. A single, broad-frequency range is used to calibrate the system and then scaled to the actual range and conditions used when measuring a device under test. The range used for calibration must be broad relative to the expected measurement conditions for the scaling to be successful. Validation studies were performed by comparing the universal calibration approach with data acquired from targeted calibration ranges based on the expected range of performance for the device under test. First, a mid-level shunt range was used for calibration and used to measure devices with lower and higher impedance. Next, a high excitation current level was used for calibration, followed by measurements using lower currents. Finally, calibration was performed over a wide frequency range and used to measure test articles with a lower set of frequencies. In all cases, the universal calibration approach compared very well with results acquired following a targeted calibration. Additionally, the shunts used for the automated calibration technique were successfully characterized such that the rapid impedance measurements compare very well with laboratory-scale measurements. These data indicate that the universal approach can be successfully used for onboard rapid impedance spectra measurements for a broad set of test devices and range of

  14. Design and construction of small sized pencil probe to measure bio-impedance.

    Science.gov (United States)

    Keshtkar, Ahmad

    2007-11-01

    Currently, bio-impedance measurements are performed with relatively large probes which are not suitable for all in vivo studies. These are typically designed and constructed for different uses, such as for cervical and oesophagus tissues and are too large for many investigations, including those involving the bladder. Therefore, it was decided to design and construct a small sized pencil probe, using a microscope to solder very small wires to a tiny tip (about 2mm in diameter). In addition, different approaches were used to construct, treat, and perform the safety tests and calibration procedure on the probe before taking impedance measurements of the urinary bladder.

  15. Evaluation of algorithms for calculating bioimpedance phase angle values from measured whole-body impedance modulus.

    Science.gov (United States)

    Nordbotten, Bernt J; Tronstad, Christian; Martinsen, Ørjan G; Grimnes, Sverre

    2011-07-01

    This paper addresses the problem of calculating the bioimpedance phase angle from measurements of impedance modulus. A complete impedance measurement was performed on altogether 20 healthy persons using a Solatron 1260/1294 system. The obtained impedance modulus (absolute impedance value) values were used to calculate the Cole parameters and from them the phase angles. In addition, the phase angles were also calculated using a Kramers-Kronig approach. A correlation analysis for all subjects at each frequency (5, 50, 100 and 200 kHz) for both methods gave R(2) values ranging from 0.7 to 0.96 for the Cole approach and from 0.83 to 0.96 for the Kramers-Kronig approach; thus, both methods gave good results compared with the complete measurement results. From further statistical significance testing of the absolute value of the difference between measured and calculated phase angles, it was found that the Cole equation method gave significantly better agreement for the 50 and 100 kHz frequencies. In addition, the Cole equation method gives the four Cole parameters (R(0), R(∞), τ(z) and α) using measurements at frequencies up to 200 kHz while the Kramers-Kronig method used frequencies up to 500 kHz to reduce the effect of truncation on the calculated results. Both methods gave results that can be used for further bioimpedance calculations, thus improving the application potential of bioimpedance measurement results obtained using relatively inexpensive and portable measurement equipment.

  16. An Electronic Measurement Instrumentation of the Impedance of a Loaded Fuel Cell or Battery

    Science.gov (United States)

    Aglzim, El-Hassane; Rouane, Amar; El-Moznine, Reddad

    2007-01-01

    In this paper we present an inexpensive electronic measurement instrumentation developed in our laboratory, to measure and plot the impedance of a loaded fuel cell or battery. Impedance measurements were taken by using the load modulation method. This instrumentation has been developed around a VXI system stand which controls electronic cards. Software under Hpvee® was developed for automatic measurements and the layout of the impedance of the fuel cell on load. The measurement environment, like the ambient temperature, the fuel cell temperature, the level of the hydrogen, etc…, were taken with several sensors that enable us to control the measurement. To filter the noise and the influence of the 50Hz, we have implemented a synchronous detection which filters in a very narrow way around the useful signal. The theoretical result obtained by a simulation under Pspice® of the method used consolidates the choice of this method and the possibility of obtaining correct and exploitable results. The experimental results are preliminary results on a 12V vehicle battery, having an inrush current of 330A and a capacity of 40Ah (impedance measurements on a fuel cell are in progress, and will be the subject of a forthcoming paper). The results were plotted at various nominal voltages of the battery (12.7V, 10V, 8V and 5V) and with two imposed currents (0.6A and 4A). The Nyquist diagram resulting from the experimental data enable us to show an influence of the load of the battery on its internal impedance. The similitude in the graph form and in order of magnitude of the values obtained (both theoretical and practical) enables us to validate our electronic measurement instrumentation. One of the future uses for this instrumentation is to integrate it with several control sensors, on a vehicle as an embedded system to monitor the degradation of fuel cell membranes.

  17. [A Digital System for Bioimpedance and Electrical Impedance Tomography Measurement System].

    Science.gov (United States)

    Chen, Xiaoyan; Gao, Nana; Huang, Huafang

    2015-06-01

    A digital system for bioimpedance and electrical impedance tomography (EIT) measurement controlled by an ATmega16 microcontroller was constructed in our laboratory. There are eight digital electrodes using AD5933 to measure the impedance of the targets, and the data is transmitted to the computer wirelessly through nRF24L01. The structure of the system, circuit design, system testing, vitro measurements of animals' tissues and electrical impedance tomography are introduced specifically in this paper. The experimental results showed that the system relative error was 0.42%, and the signal noise ratio was 76.3 dB. The system not only can be used to measure the impedance by any two electrodes within the frequency of 1-100 kHz in a sweep scanning, but also can reconstruct the images of EIT. The animal experiments showed that the data was valid and plots were fitting with Cole-Cole theory. The testing verified the feasibility and effectiveness of the system. The images reconstructed of a salt-water tank are satisfactory and match with the actual distribution of the tank. The system improves the effectiveness of the front-end measuring signal and the stability of the system greatly.

  18. Impedance spectroscopy for detection of mold in archives with an integrated reference measurement

    Science.gov (United States)

    Papireddy Vinayaka, P.; Van Den Driesche, S.; Janssen, S.; Frodl, M.; Blank, R.; Cipriani, F.; Lang, W.; Vellekoop, M. J.

    2015-06-01

    In this work, we present a new miniaturized culture medium based sensor system where we apply an optical reference in an impedance measurement approach for the detection of mold in archives. The designed sensor comprises a chamber with pre-loaded culture medium which promotes the growth of archive mold species. Growth of mold is detected by measuring changes in the impedance of the culture medium caused due to increase in the pH (from 5.5 to 8) with integrated electrodes. Integration of the reference measurement helps in determining the sensitivity of the sensor. The colorimetric principle serves as a reference measurement that indicates a pH change after which further pH shifts can be determined using impedance measurement. In this context, some of the major archive mold species Eurotium amstelodami, Aspergillus penicillioides and Aspergillus restrictus have been successfully analyzed on-chip. Growth of Eurotium amstelodami shows a proportional impedance change of 10 % (12 chips tested) per day, with a sensitivity of 0.6 kΩ/pH unit.

  19. Lorentz force electrical impedance tomography using magnetic field measurements.

    Science.gov (United States)

    Zengin, Reyhan; Gençer, Nevzat Güneri

    2016-08-21

    In this study, magnetic field measurement technique is investigated to image the electrical conductivity properties of biological tissues using Lorentz forces. This technique is based on electrical current induction using ultrasound together with an applied static magnetic field. The magnetic field intensity generated due to induced currents is measured using two coil configurations, namely, a rectangular loop coil and a novel xy coil pair. A time-varying voltage is picked-up and recorded while the acoustic wave propagates along its path. The forward problem of this imaging modality is defined as calculation of the pick-up voltages due to a given acoustic excitation and known body properties. Firstly, the feasibility of the proposed technique is investigated analytically. The basic field equations governing the behaviour of time-varying electromagnetic fields are presented. Secondly, the general formulation of the partial differential equations for the scalar and magnetic vector potentials are derived. To investigate the feasibility of this technique, numerical studies are conducted using a finite element method based software. To sense the pick-up voltages a novel coil configuration (xy coil pairs) is proposed. Two-dimensional numerical geometry with a 16-element linear phased array (LPA) ultrasonic transducer (1 MHz) and a conductive body (breast fat) with five tumorous tissues is modeled. The static magnetic field is assumed to be 4 Tesla. To understand the performance of the imaging system, the sensitivity matrix is analyzed. The sensitivity matrix is obtained for two different locations of LPA transducer with eleven steering angles from [Formula: see text] to [Formula: see text] at intervals of [Formula: see text]. The characteristics of the imaging system are shown with the singular value decomposition (SVD) of the sensitivity matrix. The images are reconstructed with the truncated SVD algorithm. The signal-to-noise ratio in measurements is assumed 80 d

  20. Lorentz force electrical impedance tomography using magnetic field measurements

    Science.gov (United States)

    Zengin, Reyhan; Güneri Gençer, Nevzat

    2016-08-01

    In this study, magnetic field measurement technique is investigated to image the electrical conductivity properties of biological tissues using Lorentz forces. This technique is based on electrical current induction using ultrasound together with an applied static magnetic field. The magnetic field intensity generated due to induced currents is measured using two coil configurations, namely, a rectangular loop coil and a novel xy coil pair. A time-varying voltage is picked-up and recorded while the acoustic wave propagates along its path. The forward problem of this imaging modality is defined as calculation of the pick-up voltages due to a given acoustic excitation and known body properties. Firstly, the feasibility of the proposed technique is investigated analytically. The basic field equations governing the behaviour of time-varying electromagnetic fields are presented. Secondly, the general formulation of the partial differential equations for the scalar and magnetic vector potentials are derived. To investigate the feasibility of this technique, numerical studies are conducted using a finite element method based software. To sense the pick-up voltages a novel coil configuration (xy coil pairs) is proposed. Two-dimensional numerical geometry with a 16-element linear phased array (LPA) ultrasonic transducer (1 MHz) and a conductive body (breast fat) with five tumorous tissues is modeled. The static magnetic field is assumed to be 4 Tesla. To understand the performance of the imaging system, the sensitivity matrix is analyzed. The sensitivity matrix is obtained for two different locations of LPA transducer with eleven steering angles from -{{25}\\circ} to {{25}\\circ} at intervals of {{5}\\circ} . The characteristics of the imaging system are shown with the singular value decomposition (SVD) of the sensitivity matrix. The images are reconstructed with the truncated SVD algorithm. The signal-to-noise ratio in measurements is assumed 80 dB. Simulation studies

  1. Ground robotic measurement of aeolian processes

    Science.gov (United States)

    Qian, Feifei; Jerolmack, Douglas; Lancaster, Nicholas; Nikolich, George; Reverdy, Paul; Roberts, Sonia; Shipley, Thomas; Van Pelt, R. Scott; Zobeck, Ted M.; Koditschek, Daniel E.

    2017-08-01

    Models of aeolian processes rely on accurate measurements of the rates of sediment transport by wind, and careful evaluation of the environmental controls of these processes. Existing field approaches typically require intensive, event-based experiments involving dense arrays of instruments. These devices are often cumbersome and logistically difficult to set up and maintain, especially near steep or vegetated dune surfaces. Significant advances in instrumentation are needed to provide the datasets that are required to validate and improve mechanistic models of aeolian sediment transport. Recent advances in robotics show great promise for assisting and amplifying scientists' efforts to increase the spatial and temporal resolution of many environmental measurements governing sediment transport. The emergence of cheap, agile, human-scale robotic platforms endowed with increasingly sophisticated sensor and motor suites opens up the prospect of deploying programmable, reactive sensor payloads across complex terrain in the service of aeolian science. This paper surveys the need and assesses the opportunities and challenges for amassing novel, highly resolved spatiotemporal datasets for aeolian research using partially-automated ground mobility. We review the limitations of existing measurement approaches for aeolian processes, and discuss how they may be transformed by ground-based robotic platforms, using examples from our initial field experiments. We then review how the need to traverse challenging aeolian terrains and simultaneously make high-resolution measurements of critical variables requires enhanced robotic capability. Finally, we conclude with a look to the future, in which robotic platforms may operate with increasing autonomy in harsh conditions. Besides expanding the completeness of terrestrial datasets, bringing ground-based robots to the aeolian research community may lead to unexpected discoveries that generate new hypotheses to expand the science

  2. Applicability of impedance measuring method to the detection of irradiation treatment of potatoes

    Energy Technology Data Exchange (ETDEWEB)

    Hayashi, Toru; Todoriki, Setsuko; Otobe, Kazunori; Sugiyama, Junnichi (National Food Research Inst., Tsukuba, Ibaraki (Japan))

    1993-05-01

    The incubation condition of potato tubers prior to impedance measurement greatly influenced the reliability of detection of irradiated potatoes; the impedance ratio at 5 kHz to 50 kHz (Z[sub 5k]/Z[sub 50k]) determined at 22degC at an apical region of tuber which was pre-incubated at 22degC for 3 days or longer resulted in the best detection of radiation treatment of potatoes. The impedance ratio was dependent upon dose applied to potato tubers. Potatoes irradiated at 100 Gy could be distinguished from unirradiated potatoes for 10 cultivars of potatoes. The impedance ratio of potatoes irradiated at the same dose was little influenced by the planting locality if the cultivar was the same, although the ratio varied with potato cultivars. These results indicate that irradiated potatoes can be detected if the potato cultivar is known. Potatoes 'Danshaku' commercially irradiated at the Shihiro Potato Irradiation Center could be differentiated from unirradiated 'Danshaku' at different planting localities; the impedance ratio was lower than 2.75 for the unirradiated potatoes and higher than 2.75 for the irradiated ones. (author).

  3. Electrode-Skin contact impedance: In vivo measurements on an ovine model

    Science.gov (United States)

    Nguyen, D. T.; Kosobrodov, R.; Barry, M. A.; Chik, W.; Jin, C.; Oh, T. I.; Thiagalingam, A.; McEwan, A.

    2013-04-01

    The problem of electrical impedance between the skin and the electrode is an on-going challenge in bio-electronics. This is particularly true in the case of Electrical Impedance Tomography (EIT), which uses a large number of skin-contact electrodes and is very sensitive to noise. In the present article, contact impedance is measured and compared for a range of electrodes placed on the thorax of an ovine model. The study has been approved by the Westmead Hospital Animal Ethics Committee. The electrode models that were employed in the research are Ag/AgCl electrodes (E1), commonly used for ECG and EIT measurements in both humans and animal models, stainless steel crocodile clips (E2), typically used on animal models, and novel multi-point dry electrodes in two modifications: bronze plated (E3) and nickel plated (E4). Further, since the contact impedance is mostly attributed to the acellular outer layer of the skin, in our experiment, we attempted to study the effect of this layer by comparing the results when the skin is intact and when electrodes are introduced underneath the skin through small cuts. This boundary effect was assessed by comparison of measurements obtained during E2 skin surface contact, and sub-cutaneous contact (E5). Twelve gauge intradermal needles were also tested as an electrode (E6). The full impedance spectrum, from 500 Hz to 300 kHz, was recorded, analysed and compared. As expected, the contact impedance in the more invasive cases, i.e the electrodes under the skin, is significantly lower than in the non-invasive cases. At the frequency of 50 kHz which is commonly used in lung EIT acquisition, electrodes E3, E4 and E6 demonstrated contact impedance of less than 200 Ω, compared to more than 400 Ω measured for electrodes E1, E2 and E5. In conclusion, the novel multipoint electrodes proved to be best suited for EIT purposes, because they are non-invasive and have lower contact impedance than Ag/AgCl and crocodile clips, in both invasive and

  4. Numerical calculation of transverse coupling impedances: Comparison to Spallation Neutron Source extraction kicker measurements

    Directory of Open Access Journals (Sweden)

    B. Doliwa

    2007-10-01

    Full Text Available The study of beam dynamics and the localization of potential sources of instabilities are important tasks in the design of modern, high-intensity particle accelerators. In the case of synchrotrons and storage rings, coupling impedance data are needed to characterize the parasitic interaction of critical components with the beam. In this article we demonstrate the application of numerical field simulations to the computation of transverse kicker coupling impedances. Based on the 3D simulation results, a parametrized model is developed to incorporate the impedance of an arbitrary pulse-forming network attached to the kicker. Detailed comparisons of numerical results with twin-wire and direct measurements are discussed at the example of the Spallation Neutron Source extraction kicker.

  5. Impedance measurements on Au microelectrodes using controlled atmosphere high temperature scanning probe microscope

    DEFF Research Database (Denmark)

    Wu, Yuehua; Hansen, Karin Vels; Jacobsen, Torben

    2011-01-01

    High temperature impedance measurements on Au microelectrodes deposited on polished yttria stabilized zirconia (YSZ) pellets were demonstrated using a newly designed controlled atmosphere high temperature scanning probe microscope (CAHT-SPM). Probes based on Pt0.8Ir0.2 were fabricated and employed...... in all the investigations. The electrical properties of the Au microelectrodes were investigated using CAHT-SPM at various temperatures in air. The influences of the tip-sample force and of the size of the microelectrode on the electrical properties of the Au microelectrodes were also studied....... The impedance spectra of circular Au microelectrodes down to 8μm in diameter at different temperatures were successfully obtained. The CAHT-SPM presented in this paper is capable of obtaining topography images, conductivity images and impedance spectra in-situ in a temperature range from room temperature...

  6. Standard practice for verification of algorithm and equipment for electrochemical impedance measurements

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    1989-01-01

    1.1 This practice covers an experimental procedure which can be used to check one's instrumentation and technique for collecting and presenting electrochemical impedance data. If followed, this practice provides a standard material, electrolyte, and procedure for collecting electrochemical impedance data at the open circuit or corrosion potential that should reproduce data determined by others at different times and in different laboratories. This practice may not be appropriate for collecting impedance information for all materials or in all environments. 1.2 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard. 1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  7. In situ electrochemical impedance and noise measurements of corroding stainless steel in high temperature water

    Energy Technology Data Exchange (ETDEWEB)

    Macak, Jan [Power Engineering Department, Institute of Chemical Technology Prague, Technicka 5, 166 28 Prague 6 (Czech Republic)]. E-mail: macakj@vscht.cz; Sajdl, Petr [Power Engineering Department, Institute of Chemical Technology Prague, Technicka 5, 166 28 Prague 6 (Czech Republic); Kucera, Pavel [Power Engineering Department, Institute of Chemical Technology Prague, Technicka 5, 166 28 Prague 6 (Czech Republic); Novotny, Radek [Institute for Energy, Joint Research Centre, 1755ZG Petten (Netherlands); Vosta, Jan [Power Engineering Department, Institute of Chemical Technology Prague, Technicka 5, 166 28 Prague 6 (Czech Republic)

    2006-04-25

    An in situ corrosion study of austenitic stainless steel 08CH18N10T in high temperature water was performed. The material under study is used in the construction of steam generator of PWR (pressurized water reactor) nuclear power stations and is similar to AISI 321 stainless steel. In situ 300-h tests were performed under autoclave conditions at 280 deg. C and 8 MPa and consisted of impedance measurements, polarization measurements and electrochemical noise measurements. The experiments were performed in deionised water with the pH adjusted to 9.5, in the presence/absence of chlorides. An additional modification of corrosivity was achieved by changing oxygen concentration. A detailed analysis of the impedance data is presented identifying in the impedance spectra contributions of oxide, corrosion reaction, double layer and diffusion process. A good agreement was found between corrosion data from electrochemical impedance spectroscopy (EIS) and that from electrochemical noise (EN) measurements. It was confirmed that the oxide response cannot be attributed to the overall oxide layer but only to the part corresponding to the space charge layer, thus indicating the semi-conductive character of the oxide.

  8. Glassy Transformation and Structural Change in Ge2Sb2Te5 Studied by Impedance Measurements

    Science.gov (United States)

    2001-06-01

    IMPEDANCE MEASUREMENTS E. Morales-Sinchezab, J. Gonzailez-Hermnndeza, E. Prokhorova "Centro de Investigaci6n y de Estudios Avanzados del IPN, Unidad...Quer6taro, Ap. Postal 1- 798, 76001, Quer6taro, Qro., Mexico. bDivisi6n de Estudios de Posgrado, Facultad de Ingenieria, UAQ, Querdtaro, Mexico. The

  9. The comparison of measured impedance of the bladder tissue with the computational modeling results

    Directory of Open Access Journals (Sweden)

    ahmad keshtkar

    2015-11-01

    Full Text Available Introduction: The electrical impedance spectroscopy technique can be used to measure the electrical impedance of the human bladder tissue, for differentiating pathological changes in the urothelium. Methods: In this study, the electrical impedance spectroscopy technique and then, a numerical technique, finite element analysis (FEA were used to model the electrical properties of this tissue to predict the impedance spectrum of the normal and malignant areas of this organ. Results: After determining and comparing the modeled data with the experimental results, it is believed that there are some factors that may affect the measurement results. Thus, the effect of inflammation, edema, changes in the applied pressure over the probe and the distensible property of the bladder tissue were considered. Furthermore, the current distribution inside the human bladder tissue was modeled in normal and malignant cases using the FEA. This model results showed that very little of the current actually flows through the urothelium and much of the injected current flows through the connective tissue beneath the urothelium. Conclusion: The results of the models do not explain the measurements results. In conclusion, there are many factors, which may account for discrepancies between the measured and modeled data.

  10. Measuring line parameters of multiconductor cables using a vector impedance meter

    OpenAIRE

    Knockaert, Jos; Peuteman, Joan; Catrysse, Johan; Belmans, Ronnie

    2010-01-01

    In the present paper, a method to measure the parameters of a multiconductor transmission line is given. The method is accurate, straightforward and only needs a single vector impedance meter or equivalent. The method has been applied for frequencies in a range from 20 kHz up to 30 MHz.

  11. Impact of hemodialysis on dual X-ray absorptiometry, bioelectrical impedance measurements, and anthropometry

    DEFF Research Database (Denmark)

    Abrahamsen, Bo; Hansen, T B; Høgsberg, I M;

    1996-01-01

    ), bioelectrical impedance analysis (BIA), and simple anthropometry in 19 patients (9 women and 10 men, mean age 46 y) before and after hemodialysis, removing 0.9-4.3 L (x: 2.8L) of ultrafiltrate. The reduction in fat-free mass (FFM) measured by DXA was highly correlated with the ultrafiltrate, as determined...

  12. Method to measure autonomic control of cardiac function using time interval parameters from impedance cardiography

    NARCIS (Netherlands)

    Meijer, J.H.; Boesveldt, S.; Elbertse, E.; Berendse, H.W.

    2008-01-01

    The time difference between the electrocardiogram and impedance cardiogram can be considered as a measure for the time delay between the electrical and mechanical activities of the heart. This time interval, characterized by the pre-ejection period (PEP), is related to the sympathetic autonomous ner

  13. [Estimation of biological tissue conductivity with contact-free magnetic impedance measurements].

    Science.gov (United States)

    Cordes, Axel; Steffen, Matthias; Leonhardt, Steffen

    2010-04-01

    At present, there are several methods that utilize electrical conductivity of biological tissue, such as biological impedance spectroscopy (BIS). Because these techniques use conductivity values for further analysis (e.g., body water distribution, etc.), accuracy of conductivity measurement is crucial. Traditionally, most impedance-based techniques rely on conductive interaction between tissue and external electrical measurement devices. Thus, electrode properties can influence the results of conductivity measurements. In this study, a contact-free measurement technique is presented, which is based on magnetic induction of eddy currents and measurement of the tiny reinduced voltages in external measurement coils. Our results indicate that it is principally possible to determine conductivity of biological tissue with this technique.

  14. Electrical impedance-based void fraction measurement and flow regime identification in microchannel flows under adiabatic conditions

    OpenAIRE

    Paranjape, Sidharth; Ritchey, Susan N; Garimella, S V

    2012-01-01

    Electrical impedance of a two-phase mixture is a function of void fraction and phase distribution. The difference in the specific electrical conductance and permittivity of the two phases is exploited to measure electrical impedance for obtaining void fraction and flow regime characteristics. An electrical impedance meter is constructed for the measurement of void fraction in microchannel two-phase flow. The experiments are conducted in air–water two-phase flow under adiabatic conditions. A t...

  15. Development and Demonstration of Measurement-Time Efficient Methods for Impedance Spectroscopy of Electrode and Sensor Arrays

    OpenAIRE

    Derek Johnson; Matthew Smith; Kevin R. Cooper

    2008-01-01

    The development of impedance-based array devices is hindered by a lack of robust platforms and methods upon which to evaluate and interrogate sensors. One aspect to be addressed is the development of measurement-time efficient techniques for broadband impedance spectroscopy of large electrode arrays. The objective of this work was to substantially increase the low frequency impedance measurement throughput capability of a large channel count array analyzer by developing true parallel measurem...

  16. Error correction algorithm for high accuracy bio-impedance measurement in wearable healthcare applications.

    Science.gov (United States)

    Kubendran, Rajkumar; Lee, Seulki; Mitra, Srinjoy; Yazicioglu, Refet Firat

    2014-04-01

    Implantable and ambulatory measurement of physiological signals such as Bio-impedance using miniature biomedical devices needs careful tradeoff between limited power budget, measurement accuracy and complexity of implementation. This paper addresses this tradeoff through an extensive analysis of different stimulation and demodulation techniques for accurate Bio-impedance measurement. Three cases are considered for rigorous analysis of a generic impedance model, with multiple poles, which is stimulated using a square/sinusoidal current and demodulated using square/sinusoidal clock. For each case, the error in determining pole parameters (resistance and capacitance) is derived and compared. An error correction algorithm is proposed for square wave demodulation which reduces the peak estimation error from 9.3% to 1.3% for a simple tissue model. Simulation results in Matlab using ideal RC values show an average accuracy of for single pole and for two pole RC networks. Measurements using ideal components for a single pole model gives an overall and readings from saline phantom solution (primarily resistive) gives an . A Figure of Merit is derived based on ability to accurately resolve multiple poles in unknown impedance with minimal measurement points per decade, for given frequency range and supply current budget. This analysis is used to arrive at an optimal tradeoff between accuracy and power. Results indicate that the algorithm is generic and can be used for any application that involves resolving poles of an unknown impedance. It can be implemented as a post-processing technique for error correction or even incorporated into wearable signal monitoring ICs.

  17. Simulations and measurements of coupling impedance for modern particle accelerator devices

    CERN Document Server

    AUTHOR|(CDS)2158523; Biancacci, Nicolò; Mostacci, Andrea

    In this document it has been treated the study of the coupling impedance in modern devices, already installed or not, in different particle accelerators. In the specific case: • For a device in-phase of project, several simulations for impedance calculation have been done. • For a component already realized and used, measurements of coupling impedance value have been done. Simulations are used to determine the impact of the interconnect between to magnets, designed for the future particle accelerator FCC, on the overall impedance of the machine which is about 100 km long. In particular has been done a check between theory, simulations and measurements of components already built, allowing a better and deeper study of the component we have analysed. Controls that probably will be helpful to have a clear guideline in future works. The measurements instead concern in an existing component that was already used in LHC, the longest particle accelerator ever realised on the planet, 27 km long. The coupling impe...

  18. End-point impedance measurements across dominant and nondominant hands and robotic assistance with directional damping.

    Science.gov (United States)

    Erden, Mustafa Suphi; Billard, Aude

    2015-06-01

    The goal of this paper is to perform end-point impedance measurements across dominant and nondominant hands while doing airbrush painting and to use the results for developing a robotic assistance scheme. We study airbrush painting because it resembles in many ways manual welding, a standard industrial task. The experiments are performed with the 7 degrees of freedom KUKA lightweight robot arm. The robot is controlled in admittance using a force sensor attached at the end-point, so as to act as a free-mass and be passively guided by the human. For impedance measurements, a set of nine subjects perform 12 repetitions of airbrush painting, drawing a straight-line on a cartoon horizontally placed on a table, while passively moving the airbrush mounted on the robot's end-point. We measure hand impedance during the painting task by generating sudden and brief external forces with the robot. The results show that on average the dominant hand displays larger impedance than the nondominant in the directions perpendicular to the painting line. We find the most significant difference in the damping values in these directions. Based on this observation, we develop a "directional damping" scheme for robotic assistance and conduct a pilot study with 12 subjects to contrast airbrush painting with and without robotic assistance. Results show significant improvement in precision with both dominant and nondominant hands when using robotic assistance.

  19. Longitudinal and Transverse Wire Measurements for the Evaluation of Impedance Reduction Measures on the MKE Extraction Kickers

    CERN Document Server

    Kroyer, T; Gaxiola, E; CERN. Geneva. AB Department

    2007-01-01

    In 2003 significant heating of the MKE Extraction kicker magnets in CERN's SPS was confirmed by measurements with beam. The dissipated power was so high that it would seriously jeopardize the good functioning of the kicker by warming the ferrite above the Curie temperature. In an impedance reduction campaign the beam coupling impedance of the present kickers was assessed with wire measurements and possible cures were evaluated. For a reliable impedance determination refined measurement methods had to be used. Any kicker modification should not deteriorate kick field quality and high voltage capability. Shielding the ferrites with printed metallic strips turned out to be a promising solution. Technological issues of the metallic coatings are also discussed.

  20. Estimation of pressure-particle velocity impedance measurement uncertainty using the Monte Carlo method.

    Science.gov (United States)

    Brandão, Eric; Flesch, Rodolfo C C; Lenzi, Arcanjo; Flesch, Carlos A

    2011-07-01

    The pressure-particle velocity (PU) impedance measurement technique is an experimental method used to measure the surface impedance and the absorption coefficient of acoustic samples in situ or under free-field conditions. In this paper, the measurement uncertainty of the the absorption coefficient determined using the PU technique is explored applying the Monte Carlo method. It is shown that because of the uncertainty, it is particularly difficult to measure samples with low absorption and that difficulties associated with the localization of the acoustic centers of the sound source and the PU sensor affect the quality of the measurement roughly to the same extent as the errors in the transfer function between pressure and particle velocity do.

  1. The effect of peripheral resistance on impedance cardiography measurements in the anesthetized dog.

    Science.gov (United States)

    Critchley, Lester A H; Peng, Zhi Y; Fok, Benny S; James, Anthony E

    2005-06-01

    In the vasodilated and septic patient, the impedance method of measuring cardiac output (CO) may underestimate the true value. In this study, we sought to determine whether impedance CO (COIC) measurements are influenced by total peripheral resistance (TPR). In eight anesthetized and ventilated dogs, a high-precision flowprobe was placed on the ascending aorta, and direct CO was measured (CO flowprobe (COFP)). Mean arterial blood pressure was measured from the femoral artery. Simultaneous COIC measurements were made. TPR (mean arterial blood pressure x 80/COFP) was varied over 1-2 h by using infusions of phenylephrine and adrenaline and inhaled halothane. The bias between methods of CO measurement (COIC-COFP) was calculated and compared with TPR by using correlation and regression analysis. A total of 547 pairs of CO measurements were collected from the 8 dogs as TPR was varied. COFP changed by a mean of 190% (range, 89%-425%), and TPR changed by a mean of 266% (range, 94%-580%) during the experiment. The impedance method underestimated CO when TPR was low and overestimated CO when TPR was high. There was a logarithmic relationship between the CO bias and TPR. Correlation coefficients (r) between the CO bias and TPR ranged from 0.46 to 0.89 (P TPR halved or doubled. This finding explains the poor agreement between COIC and other methods of CO measurement found in validation studies involving critically ill patients.

  2. Grounding the randomness of quantum measurement.

    Science.gov (United States)

    Jaeger, Gregg

    2016-05-28

    Julian Schwinger provided to physics a mathematical reconstruction of quantum mechanics on the basis of the characteristics of sequences of measurements occurring at the atomic level of physical structure. The central component of this reconstruction is an algebra of symbols corresponding to quantum measurements, conceived of as discrete processes, which serve to relate experience to theory; collections of outcomes of identically circumscribed such measurements are attributed expectation values, which constitute the predictive content of the theory. The outcomes correspond to certain phase parameters appearing in the corresponding symbols, which are complex numbers, the algebra of which he finds by a process he refers to as 'induction'. Schwinger assumed these (individually unpredictable) phase parameters to take random, uniformly distributed definite values within a natural range. I have previously suggested that the 'principle of plenitude' may serve as a basis in principle for the occurrence of the definite measured values that are those members of the collections of measurement outcomes from which the corresponding observed statistics derive (Jaeger 2015Found. Phys.45, 806-819. (doi:10.1007/s10701-015-9893-6)). Here, I evaluate Schwinger's assumption in the context of recent critiques of the notion of randomness and explicitly relate the randomness of these phases with the principle of plenitude and, in this way, provide a fundamental grounding for the objective, physically irreducible probabilities, conceived of as graded possibilities, that are attributed to measurement outcomes by quantum mechanics.

  3. Method for Flow Measurement in Microfluidic Channels Based on Electrical Impedance Spectroscopy

    CERN Document Server

    Arjmandi, Nima; Van Roy, Willem; Lagae, Liesbet; Borghs, Gustaaf; 10.1007/s10404-011-0843-0

    2012-01-01

    We have developed and characterized two novel micro flow sensors based on measuring the electrical impedance of the interface between the flowing liquid and metallic electrodes embedded on the channel walls. These flow sensors are very simple to fabricate and use, are extremely compact and can easily be integrated into most microfluidic systems. One of these devices is a micropore with two tantalum/platinum electrodes on its edges; the other is a micro channel with two tantalum /platinum electrodes placed perpendicular to the channel on its walls. In both sensors the flow rate is measured via the electrical impedance between the two metallic electrodes, which is the impedance of two metal-liquid junctions in series. The dependency of the metal-liquid junction impedance on the flow rate of the liquid has been studied. The effects of different parameters on the sensor's outputs and its noise behavior are investigated. Design guidelines are extracted and applied to achieve highly sensitive micro flow sensors wit...

  4. Interpulse multifrequency electrical impedance measurements during electroporation of adherent differentiated myotubes.

    Science.gov (United States)

    García-Sánchez, Tomás; Azan, Antoine; Leray, Isabelle; Rosell-Ferrer, Javier; Bragós, Ramon; Mir, Lluis M

    2015-10-01

    In this study, electrical impedance spectroscopy measurements are performed during electroporation of monolayers of differentiated myotubes. The time resolution of the system (1 spectrum/ms) enable 860 full spectra (21 frequencies from 5 kHz to 1.3 MHz) to be acquired during the time gap between consecutive pulses (interpulse) of a classical electroporation treatment (8 pulses, 100 μs, 1 Hz). Additionally, the characteristics of the custom microelectrode assembly used allow the experiments to be performed directly in situ in standard 24 multi-well plates. The impedance response dynamics are studied for three different electric field intensities (400, 800 and 1200 V/cm). The multifrequency information, analysed with the Cole model, reveals a short-term impedance recovery after each pulse in accordance with the fast resealing of the cell membrane, and a long-term impedance decay over the complete treatment in accordance with an accumulated effect pulse after pulse. The analysis shows differences between the lowest electric field condition and the other two, suggesting that different mechanisms that may be related with the reversibility of the process are activated. As a result of the multifrequency information, the system is able to measure simultaneously the conductivity variations due to ion diffusion during electroporation. Finally, in order to reinforce the physical interpretation of the results, a complementary electrical equivalent model is used.

  5. A cable-free impedance and gain measurement technique for electrically small antennas

    DEFF Research Database (Denmark)

    Pivnenko, Sergey; Zhang, Jiaying; Breinbjerg, Olav

    2010-01-01

    are represented in terms of spherical wave expansions (SWEs), and the propagation is accounted for by a transmission formula. In this paper the measurement results by the proposed technique will be presented for several AUTs, including a standard gain horn antenna, a monopole antenna, and an electrically small......Impedance and gain measurements for electrically small antennas represent a great challenge due to influences of the feeding cable. The leaking current along the cable and scattering effects are two main issues caused by the feed line. In this paper, a novel cable-free antenna impedance and gain...... measurement technique for electrically small antennas is proposed. The antenna properties are extracted by measuring the signal scattered by the antenna under test (AUT), when it is loaded with three known loads. The technique is based on a rigorous electromagnetic model where the probe and AUT...

  6. Impedance Measurements as a Tool for the Detection of Endocrine Disrupting Chemicals

    Science.gov (United States)

    2007-11-02

    endocrine disruptors on human health has created a need for screening systems to detect xenoestrogens, a diverse group of chemicals that mimic...Impedance Measurements as a Tool for the Detection of Endocrine Disrupting Chemicals V. Sacks, J. Rishpon* Department of Molecular...sensitive and amenable to use on-site, providing an efficient and economic tool for measuring minuscule amounts of endocrine disrupting chemicals

  7. Polynomial Collocation for Handling an Inaccurately Known Measurement Configuration in Electrical Impedance Tomography

    DEFF Research Database (Denmark)

    Hyvönen, Niina; Kaarnioja, V.; Mustonen, L.

    2017-01-01

    The objective of electrical impedance tomography is to reconstruct the internal conductivity of a physical body based on measurements of current and potential at a finite number of electrodes attached to its boundary. Although the conductivity is the quantity of main interest in impedance...... tomography, a real-world measurement configuration includes other unknown parameters as well: The information on the contact resistances, electrode positions, and body shape is almost always incomplete. In this work, the dependence of the electrode measurements on all aforementioned model properties...... is parametrized via polynomial collocation. The availability of such a parametrization enables efficient simultaneous reconstruction of the conductivity and other unknowns by a Newton-type output least squares algorithm, which is demonstrated by two-dimensional numerical experiments based on both noisy simulated...

  8. Comparison between laboratory measurements, simulations, and analytical predictions of the transverse wall impedance at low frequencies

    CERN Document Server

    Roncarolo, F; Kroyer, T; Metral, E; Mounet, N; Salvant, B; Zotter, B

    2009-01-01

    The prediction of the transverse wall beam impedance at the first unstable betatron line (8 kHz) of the CERN Large Hadron Collider (LHC) is of paramount importance for understanding and controlling the related coupled-bunch instabilities. Until now only novel analytical formulas were available at this frequency. Recently, laboratory measurements and numerical simulations were performed to cross-check the analytical predictions. The experimental results based on the measurement of the variation of a probe coil inductance in the presence of (i) sample graphite plates, (ii) stand-alone LHC collimator jaws, and (iii) a full LHC collimator assembly are presented in detail. The measurement results are compared to both analytical theories and simulations. In addition, the consequences for the understanding of the LHC impedance are discussed.

  9. In Situ Measurement of the Undisturbed Ground Temperature for Ground Source Heat Pump System

    Institute of Scientific and Technical Information of China (English)

    ZHOU Ya-su

    2008-01-01

    The undisturbed ground are important for design of the ground heat exchangers in ground source heat pump (GSHP) systems. In this paper, the undisturbed ground temperatures measured in two different methods are presented. The investigation was carried out in two cases. The temperature measured with the direct method is assumed to give the correct undisturbed ground temperature profile. The temperature measured with indirect method overestimates the undisturbed ground temperature by 2.1℃ and 1.7℃. This difference is mainly caused by the circulation pump and ambient air to the fluid. Therefore, the results that are decreased about 2℃ as compared with the indirect measured are recommended to estimate the undisturbed ground temperature in situ measuring. A smaller pump or deeper borehole or mild weather would result in a more correct temperature. Because the undisturbed ground temperature is affected by many factors. Whether or not these conclusions are correct to other areas, this would need further investigation.

  10. A compact wideband precision impedance measurement system based on digital auto-balancing bridge

    Science.gov (United States)

    Hu, Binxin; Wang, Jinyu; Song, Guangdong; Zhang, Faxiang

    2016-05-01

    The ac impedance spectroscopy measurements are predominantly taken by using impedance analyzers based on analog auto-balancing bridge. However, those bench-top analyzers are generally complicated, bulky and expensive, thus limiting their usage in industrial field applications. This paper presents the development of a compact wideband precision measurement system based on digital auto-balancing bridge. The methods of digital auto-balancing bridge and digital lock-in amplifier are analyzed theoretically. The overall design and several key sections including null detector, direct digital synthesizer-based sampling clock, and digital control unit are introduced in detail. The results show that the system achieves a basic measurement accuracy of 0.05% with a frequency range of 20 Hz-2 MHz. The advantages of versatile measurement capacity, fast measurement speed, small size and low cost make it quite suitable for industrial field applications. It is demonstrated that this system is practical and effective by applying in determining the impedance-temperature characteristic of a motor starter PTC thermistor.

  11. Evaluation of impedance on biological Tissues using automatic control measurement system

    Energy Technology Data Exchange (ETDEWEB)

    Kil, Sang Hyeong; Shin, Dong Hoon; Lee, Seong Mo [Pusan National University, Yangsan (Korea, Republic of); Lee, Moo Seok; Kim, Sang Sik [Pusan National University, Busan (Korea, Republic of); Kim, Gun FDo; Lee, Jong Kyu [Pukyung National University, Busan (Korea, Republic of)

    2015-08-15

    Each biological tissue has endemic electrical characteristics owing to various differences such as those in cellular arrangement or organization form. The endemic electrical characteristics change when any biological change occurs. This work is a preliminary study surveying the changes in the electrical characteristics of biological tissue caused by radiation exposure. For protection against radiation hazards, therefore the electrical characteristics of living tissue were evaluated after development of the automatic control measurement system using LabVIEW. No alteration of biological tissues was observed before and after measurement of the electrical characteristics, and the biological tissues exhibited similar patterns. Through repeated measurements using the impedance/gain-phase analyzer, the coefficient of variation was determined as within 10%. The reproducibility impedance phase difference in electrical characteristics of the biological tissue did not change, and the tissue had resistance. The absolute value of impedance decreased constantly in proportion to the frequency. It has become possible to understand the electrical characteristics of biological tissues through the measurements made possible by the use of the developed.

  12. Use of low-frequency electrical impedance measurements to determine phospholipid content in amniotic fluid

    Science.gov (United States)

    DeLuca, F.; Cametti, C.; Zimatore, G.; Maraviglia, B.; Pachi', A.

    1996-09-01

    In this report we propose a new method for an in vitro test of the foetal lung maturity based on the measurement of the electrical conductivity of the overall amniotic fluid obtained from transabdominal amniocentesis, since this quantity can be linked to a first approximation in a very simple way to the phospholipid content. We have carried out measurements of 85 different samples of amniotic fluid as a function of gestation weeks and we have observed a pronounced change of the electrical conductivity that reflects the increase in the phospholipid concentration occurring at the end of normal pregnancies. The method could be further developed to obtain similar information on in vivo experiments by means of bioelectric impedance tomography, taking advantage of the frequency dependence of the tissue electrical impedance.

  13. Estimation of membrane hydration status for standby proton exchange membrane fuel cell systems by impedance measurement

    DEFF Research Database (Denmark)

    Bidoggia, Benoit; Rugholt, Mark; Nielsen, Morten Busk

    2014-01-01

    Fuel cells are getting growing interest in both backup systems and electric vehicles. Although these systems are characterized by long periods of inactivity, they must be able to start at any instant in the shortest time. However, the membrane of which PEMFCs are made tends to dry out when...... not in use. This increases the time required to start the system and could lead to the destruction of the fuel cell. In this article an impedance measurement circuit is presented, which is part of a humidity status estimator for monitoring the humidity status of a fuel cell stack during standby....... The impedance measurement circuit has been connected to a fuel cell stack and the operation of estimating the relative humidity has been demonstrated....

  14. A Planar Interdigital Sensor for Bio-impedance Measurement: Theoretical analysis, Optimization and Simulation

    Directory of Open Access Journals (Sweden)

    Thanh-Tuan Ngo

    2014-04-01

    Full Text Available This paper proposes the design of a biosensor to characterize the dielectric and conductive properties of biological materials (for example blood or water by impedance spectroscopy. Particularly, its design optimized the geometric structure interdigitated electrodes. This optimization allows extending the frequency range of measurement by reducing the polarization effect. Polarization effect is manifested by an interface capability (or double layer from interaction between ions and molecules in the boundary between the surface of the electrolyte and the electrodes, it increases the measurement error at low frequencies. This paper recommends also a novel method to determine the parameters (relative permittivity, thickness and capacitance per unit area of the double layer (DL at the contact surface of the electrode with the solution. CoventorWare software was utilized to modelize of interdigital sensor structure in three dimensions (3D to verify the analytical results and evaluate the influence of geometrical parameters and the dielectric properties of the medium on bioelectrical impedance.

  15. Redefining the Attraction Measure, Scaling Exponent and Impedance Function of the Gravity Model

    CERN Document Server

    Chen, Yanguang

    2013-01-01

    The attraction measure, scaling exponent, and impedance function of the gravity model are redefined using the concepts from fractals and spatial complexity. Firstly, the attraction measure of spatial interaction in human systems is defined by the product of traffic inflow and outflow. Based on the new definition, the gravity model originating from the Newtonian analogy is differentiated from Wilson's spatial interaction model deriving from entropy-maximizing principle. Secondly, the scaling exponent of the gravity model based on the inverse distance relationship is revealed to be the ratio of the fractal dimension of networks of cities to that of hierarchies of cities. The value of the scaling exponent is then shown to approach to 2, which corresponds to the value of the power exponent of the law of gravity in classical physics. Thirdly, the inverse power function is demonstrated to be more acceptable than the negative exponential function as an impedance function of the gravity model. The limits of applicati...

  16. Minimal implementation of an AFE4300-based spectrometer for electrical impedance spectroscopy measurements

    Science.gov (United States)

    Sanchez, B.; Praveen, A.; Bartolome, E.; Soundarapandian, K.; Bragos, R.

    2013-04-01

    The AFE4300 is a new low-cost on-chip impedance spectrometer developed by Texas Instruments able to handle multiple four electrode interface measurements. In this work, we present a brief description and characterization of this device and, besides its interesting features as a body-composition impedancemeter system; we evaluate its potential to develop minimal implementations for other biomedical applications. As the case study presented in this paper, its use to monitor ventilatory time-varying bioimpedance.

  17. Influence of a laser profile in impedance mismatch techniques applied to carbon EOS measurement

    Institute of Scientific and Technical Information of China (English)

    A.Aliverdiev; D.Batani; R.Dezulian

    2013-01-01

    We present a recent numerical analysis of impedance mismatch technique applied to carbon equation of state measurements.We consider high-power laser pulses with a Gaussian temporal profile of different durations.We show that for the laser intensity(≈1014W/cm2)and the target design considered in this paper we need to have laser pulses with rise-time less than 150 ps.

  18. Real-time measurement of glucose using chrono-impedance technique on a second generation biosensor.

    Science.gov (United States)

    Mayorga Martinez, Carmen C; Treo, Ernesto F; Madrid, Rossana E; Felice, Carmelo C

    2011-11-15

    Chrono-impedance technique (CIT) was implemented as a new transduction method for real time measurement of glucose in a biosensor system based in carbon paste (CP)/Ferrocene (FC)/glucose oxidase (GOx). The system presents high selectivity because the optimal stimulation signal composed by a 165mV DC potential and 50mV(RMS) AC signal at 0.4Hz was used. The low DC potential used decreased the interfering species effect and the biosensor showed a linear impedance response toward glucose detection at concentrations from 0mM to 20mM,with 0.9853 and 0.9945 correlation coefficient for impedance module (|Z|) and phase (Φ), respectively. The results of quadruplicate sets reveal the high repeatability and reproducibility of the measurements with a relative standard deviation (RSD) less than 10%. CIT presented good accuracy (within 10% of the actual value) and precision did not exceed 15% of RSD for high concentration values and 20% for the low concentration ones. In addition, a high correlation coefficient (R(2)=0.9954) between chrono-impedance and colorimetric methods was obtained. On the other hand, when two samples prepared at the same conditions were measured in parallel with both methods (the measurement was repeated four times), it should be noticed that student's t-test produced no difference between the two mentioned methods (p=1). The biosensor system hereby presented is highly specific to glucose detection and shows a better linear range than the one reported on the previous article.

  19. Measurements of complex impedance in microwave high power systems with a new bluetooth integrated circuit.

    Science.gov (United States)

    Roussy, Georges; Dichtel, Bernard; Chaabane, Haykel

    2003-01-01

    By using a new integrated circuit, which is marketed for bluetooth applications, it is possible to simplify the method of measuring the complex impedance, complex reflection coefficient and complex transmission coefficient in an industrial microwave setup. The Analog Devices circuit AD 8302, which measures gain and phase up to 2.7 GHz, operates with variable level input signals and is less sensitive to both amplitude and frequency fluctuations of the industrial magnetrons than are mixers and AM crystal detectors. Therefore, accurate gain and phase measurements can be performed with low stability generators. A mechanical setup with an AD 8302 is described; the calibration procedure and its performance are presented.

  20. Evaluation of indirect impedance for measuring microbial growth in complex food matrices.

    Science.gov (United States)

    Johnson, N; Chang, Z; Bravo Almeida, C; Michel, M; Iversen, C; Callanan, M

    2014-09-01

    The suitability of indirect impedance to accurately measure microbial growth in real food matrices was investigated. A variety of semi-solid and liquid food products were inoculated with Bacillus cereus, Listeria monocytogenes, Staphylococcus aureus, Lactobacillus plantarum, Pseudomonas aeruginosa, Escherichia coli, Salmonella enteriditis, Candida tropicalis or Zygosaccharomyces rouxii and CO2 production was monitored using a conductimetric (Don Whitely R.A.B.I.T.) system. The majority (80%) of food and microbe combinations produced a detectable growth signal. The linearity of conductance responses in selected food products was investigated and a good correlation (R(2) ≥ 0.84) was observed between inoculum levels and times to detection. Specific growth rate estimations from the data were sufficiently accurate for predictive modeling in some cases. This initial evaluation of the suitability of indirect impedance to generate microbial growth data in complex food matrices indicates significant potential for the technology as an alternative to plating methods.

  1. A nanoporous thin-film miniature interdigitated capacitive impedance sensor for measuring humidity

    Directory of Open Access Journals (Sweden)

    T. Islam

    2014-07-01

    Full Text Available This paper presents a development of a low-cost miniature humidity sensor with an interdigitated aluminium electrode connected in parallel on quartz substrate. Interdigitated capacitive device has been fabricated using the photolithography method. The aluminium electrode was covered with sensitive film of a nanoporous thin film of γ-Al2O3 made from novel sol–gel technique. Nanostructured thin film offers very high surface to volume ratio with distribution of micro pores for moisture detection. Pore morphologies of the film have been studied by field emission electron microscope and X-ray diffraction methods. Impedance measurement of the miniature capacitive humidity sensor toward relative humidity was investigated at room temperature by Agilent 4294A impedance analyzer (Agilent, Santa Clara, CA, USA. The device exhibits short response and recovery times and good repeatability.

  2. Measurement of the coupling impedances of the kickers in the SIS and ESR at GSI.

    Science.gov (United States)

    Blell, U.

    1997-05-01

    At high particle intensities coherent transverse beam oscillations may be excited due to the coupling of the beam to individual accelerators structures. The characteristic values to describe these beam instabilities are the longitudinal- and transverse coupling impedances. One reason for this beam instability is the inductive interaction between the beam and the kicker magnets. The type of the magnet, e.g. window-frame magnet or C-magnet, and its external electrical network are the most important quantities to identify the coupling impedances below the cut-off frequency of the beam pipe. For the kicker modules in the SIS and ESR accelerators at GSI the mathematical basis, theory and measured results will be presented.

  3. Dependence of Impedance Measurement Sensitivity of Cell Growth on Sensing Area of Circular Interdigitated Electrode.

    Science.gov (United States)

    Park, Jinsoo; Hwang, Kyo Seon; Cho, Sungbo

    2015-10-01

    A circular interdigitated electrode (IDE) array for label-free and real-time impedance monitoring of cell growth was fabricated and evaluated. Both the width and spacing of fingers were 50 μm, and the exposed sensing area of the circular IDE was 1.3~3.4 mm. The electrical characteristics of the fabricated circular IDE were modeled as an equivalent circuit, and the values of the circuit parameters extrapolated from the fitting to the measured spectra in different concentrations of NaCl or sensing areas of the circular IDE were analyzed. During cell growth, the resistance of cells extrapolated from the fitting was increased and the maximum rate of change in the real part of the impedance was observed at frequencies of 10 to 22 kHz. The normalized real part of the impedance measured at 10 kHz during cell growth was increased more with decreasing the electrode sensing area, albeit the number of cells to be investigated showed a corresponding increase.

  4. Impedance measurements and simulations for the LHC and HL-LHC injection protection collimator

    CERN Document Server

    AUTHOR|(CDS)2125995; Biancacci, Nicolò

    This thesis focuses on the study and the data analysis of the Injection Protection Collimator (also Injection Protection Target Dump or TDI), one of the Large Hadron Collider (LHC) collimators at CERN, in Geneva. The last chapters also deal with the Segmented TDI (TDIS), the TDI upgrade for High Luminosity-LHC (HL-LHC). Going more into details, measurements on the TDI - hexagonal Boron Nitride (TDI - hBN, installed in the LHC during run 2015) were carried out. Using the obtained results as an input, two derivations followed: one evaluating the layer resistivity and the other one for its thickness, in order to consider all the possible coating degradations that could occur. The whole range of data obtained from both the derivations was then fed to Impedance Wake 2D (IW2D), a code performing numerical simulations, to attain impedances. Finally, the resulting longitudinal impedance was compared to some measurements performed on the real TDIs, immediately after they were removed from the LHC. The TDI - Graphite, ...

  5. Impedance measurement set-up based on off-the-shelf PXI modules

    Science.gov (United States)

    Pettersen, F. J.; Martinsen, Ø. G.; Grimnes, S.; Høgetveit, J. O.

    2010-04-01

    As bioimpedance measurements are being done in an increasing variety of measurands and environments, measurement equipment must be flexible in use and easy to handle for the researcher. Measurement equipment used today is excellent for a range of uses, but it is often bulky, heavy, and not very flexible. A new compact and flexible measurement set-up based on off-the-shelf modules is described. The system is based on commercially available PXI-modules, one module that may be custom made, and custom software. The basis of the system is a PXI chassis with a power supply unit. The chassis is equipped with a controller module running software controlling the system, a signal generator, and a multichannel digitizer. All of this is commercially available. Both a custom made and a commercially available impedance interfaces were used. A LabVIEW program is controlling the measurement system, and provides a user interface. The LabVIEW program handles necessary signal conditioning and calibration. The measurement system is capable of doing frequency response measurements at frequencies up to 15 MHz. In addition to the two normal voltage pick-up electrodes used in four-electrode measurements, this system has the possibility to use 5 extra voltage pick-up electrodes. This simplifies exploration of segmental impedance, anisotropy, reciprocity, etc.

  6. A Cognitively Grounded Measure of Pronunciation Distance

    Science.gov (United States)

    Wieling, Martijn; Nerbonne, John; Bloem, Jelke; Gooskens, Charlotte; Heeringa, Wilbert; Baayen, R. Harald

    2014-01-01

    In this study we develop pronunciation distances based on naive discriminative learning (NDL). Measures of pronunciation distance are used in several subfields of linguistics, including psycholinguistics, dialectology and typology. In contrast to the commonly used Levenshtein algorithm, NDL is grounded in cognitive theory of competitive reinforcement learning and is able to generate asymmetrical pronunciation distances. In a first study, we validated the NDL-based pronunciation distances by comparing them to a large set of native-likeness ratings given by native American English speakers when presented with accented English speech. In a second study, the NDL-based pronunciation distances were validated on the basis of perceptual dialect distances of Norwegian speakers. Results indicated that the NDL-based pronunciation distances matched perceptual distances reasonably well with correlations ranging between 0.7 and 0.8. While the correlations were comparable to those obtained using the Levenshtein distance, the NDL-based approach is more flexible as it is also able to incorporate acoustic information other than sound segments. PMID:24416119

  7. A cognitively grounded measure of pronunciation distance.

    Science.gov (United States)

    Wieling, Martijn; Nerbonne, John; Bloem, Jelke; Gooskens, Charlotte; Heeringa, Wilbert; Baayen, R Harald

    2014-01-01

    In this study we develop pronunciation distances based on naive discriminative learning (NDL). Measures of pronunciation distance are used in several subfields of linguistics, including psycholinguistics, dialectology and typology. In contrast to the commonly used Levenshtein algorithm, NDL is grounded in cognitive theory of competitive reinforcement learning and is able to generate asymmetrical pronunciation distances. In a first study, we validated the NDL-based pronunciation distances by comparing them to a large set of native-likeness ratings given by native American English speakers when presented with accented English speech. In a second study, the NDL-based pronunciation distances were validated on the basis of perceptual dialect distances of Norwegian speakers. Results indicated that the NDL-based pronunciation distances matched perceptual distances reasonably well with correlations ranging between 0.7 and 0.8. While the correlations were comparable to those obtained using the Levenshtein distance, the NDL-based approach is more flexible as it is also able to incorporate acoustic information other than sound segments.

  8. A cognitively grounded measure of pronunciation distance.

    Directory of Open Access Journals (Sweden)

    Martijn Wieling

    Full Text Available In this study we develop pronunciation distances based on naive discriminative learning (NDL. Measures of pronunciation distance are used in several subfields of linguistics, including psycholinguistics, dialectology and typology. In contrast to the commonly used Levenshtein algorithm, NDL is grounded in cognitive theory of competitive reinforcement learning and is able to generate asymmetrical pronunciation distances. In a first study, we validated the NDL-based pronunciation distances by comparing them to a large set of native-likeness ratings given by native American English speakers when presented with accented English speech. In a second study, the NDL-based pronunciation distances were validated on the basis of perceptual dialect distances of Norwegian speakers. Results indicated that the NDL-based pronunciation distances matched perceptual distances reasonably well with correlations ranging between 0.7 and 0.8. While the correlations were comparable to those obtained using the Levenshtein distance, the NDL-based approach is more flexible as it is also able to incorporate acoustic information other than sound segments.

  9. Evaluation of measurement and stimulation patterns in open electrical impedance tomography with scanning electrode.

    Science.gov (United States)

    Liu, Jinzhen; Xiong, Hui; Lin, Ling; Li, Gang

    2015-07-01

    The reconstruction quality in electrical impedance tomography is limited by the current injection amplitude, the injection and measurement patterns, and the measurement accuracy as well as the number and placement of electrodes. This paper dedicates to increase the number of independent voltage measurements by scanning electrode (SE), and design an optimal measurement and stimulation pattern for open electrical impedance tomography (OEIT). Firstly, several measurement patterns are, performed in OEIT, aiming to evaluate the right number of the measurement points for the imaged target in a certain depth. The results indicate that the image quality gets higher with the number of measurement point increased to some extent. Thus, it can guide the optimum design for the electrode system in OEIT. Secondly, through the numerical calculation and salt water tank experiment, in contrast to adjacent current injection pattern, cross-current-injection pattern achieves better reconstruction with higher imaging quality and penetration depth, and is more robust against data noise in deep domain. Lastly, the experiments also indicate that the electrode contact area affects the reconstruction quality and investigation depth. Therefore, OEIT with SE can improve the application in clinic, such as the detection and monitoring of vascular, breast, and pulmonary diseases.

  10. Producing of Impedance Tube for Measurement of Acoustic Absorption Coefficient of Some Sound Absorber Materials

    Directory of Open Access Journals (Sweden)

    R. Golmohammadi

    2008-04-01

    Full Text Available Introduction & Objective: Noise is one of the most important harmful agents in work environment. In spit of industrial improvements, exposure with over permissible limit of noise is counted as one of the health complication of workers. In Iran, do not exact information of the absorption coefficient of acoustic materials. Iranian manufacturer have not laboratory for measured of sound absorbance of their products, therefore using of sound absorber is limited for noise control in industrial and non industrial constructions. The goal of this study was to design an impedance tube based on pressure method for measurement of the sound absorption coefficient of acoustic materials.Materials & Methods: In this study designing of measuring system and method of calculation of sound absorption based on a available equipment and relatively easy for measurement of the sound absorption coefficient related to ISO10534-1 was performed. Measuring system consist of heavy asbestos tube, a pure tone sound generator, calibrated sound level meter for measuring of some commonly of sound absorber materials was used. Results: In this study sound absorption coefficient of 23 types of available acoustic material in Iran was tested. Reliability of results by three repeat of measurement was tested. Results showed that the standard deviation of sound absorption coefficient of study materials was smaller than .Conclusion: The present study performed a necessary technology of designing and producing of impedance tube for determining of acoustical materials absorption coefficient in Iran.

  11. An Electronic Measurement Instrumentation of the Impedance of a Loaded Fuel Cell or Battery

    Directory of Open Access Journals (Sweden)

    Reddad El-Moznine

    2007-10-01

    Full Text Available In this paper we present an inexpensive electronic measurement instrumentationdeveloped in our laboratory, to measure and plot the impedance of a loaded fuel cell orbattery. Impedance measurements were taken by using the load modulation method. Thisinstrumentation has been developed around a VXI system stand which controls electroniccards. Software under Hpvee® was developed for automatic measurements and the layout ofthe impedance of the fuel cell on load. The measurement environment, like the ambienttemperature, the fuel cell temperature, the level of the hydrogen, etc..., were taken withseveral sensors that enable us to control the measurement. To filter the noise and theinfluence of the 50Hz, we have implemented a synchronous detection which filters in a verynarrow way around the useful signal. The theoretical result obtained by a simulation underPspice® of the method used consolidates the choice of this method and the possibility ofobtaining correct and exploitable results. The experimental results are preliminary results ona 12V vehicle battery, having an inrush current of 330A and a capacity of 40Ah (impedancemeasurements on a fuel cell are in progress, and will be the subject of a forthcoming paper.The results were plotted at various nominal voltages of the battery (12.7V, 10V, 8V and 5Vand with two imposed currents (0.6A and 4A. The Nyquist diagram resulting from theexperimental data enable us to show an influence of the load of the battery on its internalimpedance. The similitude in the graph form and in order of magnitude of the valuesobtained (both theoretical and practical enables us to validate our electronic measurementinstrumentation. One of the future uses for this instrumentation is to integrate it with several control sensors, on a vehicle as an embedded system to monitor the degradation of fuel cell membranes.

  12. The performance of integrated transconductance amplifiers as variable current sources for bio-electric impedance measurements.

    Science.gov (United States)

    Smith, D N

    1992-01-01

    Multiple applied current impedance measurement systems require numbers of current sources which operate simultaneously at the same frequency and within the same phase but at variable amplitudes. Investigations into the performance of some integrated operational transconductance amplifiers as variable current sources are described. Measurements of breakthrough, non-linearity and common-mode output levels for LM13600, NE5517 and CA3280 were carried out. The effects of such errors on the overall performance and stability of multiple current systems when driving floating loads are considered.

  13. Measurements of Electrode Skin Impedances using Carbon Rubber Electrodes - First Results

    Science.gov (United States)

    Kaufmann, Steffen; Ardelt, Gunther; Ryschka, Martin

    2013-04-01

    Non-invasive bioimpedance measurement as a tool in biomedical engineering and life sciences allows conclusions about condition and composition of living tissue. For interfacing the electronic conduction of the instrumentation and the ionic conduction of the tissue, electrodes are needed. A crucial point is the uncertainty arising from the unknown, time-varying and current density depend Electrode Skin Impedance (ESI). This work presents ESI measurements using carbon rubber electrodes on different human test subjects. The measurements for this work are carried out by employing a high accuracy Bioimpedance Measurement System (BMS) developed by the authors group, which is based on a Field Programmable Gate Array (FPGA) System on Chip (SoC). The system is able to measure magnitude and phase of complex impedances using a two- or four-electrode setup, with excitation currents from 60 μA to 5 mA in a frequency range from about 10 kHz to 300 kHz. Achieved overall measurement uncertainties are below 1%.

  14. A new lithium-ion battery internal temperature on-line estimate method based on electrochemical impedance spectroscopy measurement

    Science.gov (United States)

    Zhu, J. G.; Sun, Z. C.; Wei, X. Z.; Dai, H. F.

    2015-01-01

    The power battery thermal management problem in EV (electric vehicle) and HEV (hybrid electric vehicle) has been widely discussed, and EIS (electrochemical impedance spectroscopy) is an effective experimental method to test and estimate the status of the battery. Firstly, an electrochemical-based impedance matrix analysis for lithium-ion battery is developed to describe the impedance response of electrochemical impedance spectroscopy. Then a method, based on electrochemical impedance spectroscopy measurement, has been proposed to estimate the internal temperature of power lithium-ion battery by analyzing the phase shift and magnitude of impedance at different ambient temperatures. Respectively, the SoC (state of charge) and temperature have different effects on the impedance characteristics of battery at various frequency ranges in the electrochemical impedance spectroscopy experimental study. Also the impedance spectrum affected by SoH (state of health) is discussed in the paper preliminary. Therefore, the excitation frequency selected to estimate the inner temperature is in the frequency range which is significantly influenced by temperature without the SoC and SoH. The intrinsic relationship between the phase shift and temperature is established under the chosen excitation frequency. And the magnitude of impedance related to temperature is studied in the paper. In practical applications, through obtaining the phase shift and magnitude of impedance, the inner temperature estimation could be achieved. Then the verification experiments are conduced to validate the estimate method. Finally, an estimate strategy and an on-line estimation system implementation scheme utilizing battery management system are presented to describe the engineering value.

  15. Visualized Multiprobe Electrical Impedance Measurements with STM Tips Using Shear Force Feedback Control

    Directory of Open Access Journals (Sweden)

    Luis Botaya

    2016-05-01

    Full Text Available Here we devise a multiprobe electrical measurement system based on quartz tuning forks (QTFs and metallic tips capable of having full 3D control over the position of the probes. The system is based on the use of bent tungsten tips that are placed in mechanical contact (glue-free solution with a QTF sensor. Shear forces acting in the probe are measured to control the tip-sample distance in the Z direction. Moreover, the tilting of the tip allows the visualization of the experiment under the optical microscope, allowing the coordination of the probes in X and Y directions. Meanwhile, the metallic tips are connected to a current–voltage amplifier circuit to measure the currents and thus the impedance of the studied samples. We discuss here the different aspects that must be addressed when conducting these multiprobe experiments, such as the amplitude of oscillation, shear force distance control, and wire tilting. Different results obtained in the measurement of calibration samples and microparticles are presented. They demonstrate the feasibility of the system to measure the impedance of the samples with a full 3D control on the position of the nanotips.

  16. Vertical impedance measurements of concrete bridge deck cover condition without a direct electrical connection to the reinforcing steel

    Science.gov (United States)

    Mazzeo, Brian A.; Baxter, Jared; Barton, Jeffrey; Guthrie, W. Spencer

    2017-02-01

    Vertical impedance measurements provide significant quantitative information about the ability of concrete cover to slow the penetration of chloride ions that can corrode steel reinforcement in a bridge deck. The primary limitations preventing the widespread adoption of vertical impedance for assessment of concrete bridge decks are (1) the necessity to have a direct electrical connection to the embedded steel reinforcement and (2) the low speeds of data acquisition. This work presents solutions to both limitations. A method using a large-area electrode as a reference electrode for vertical impedance testing is validated using both simulations and measurements in the field.

  17. Ground strain measuring system using optical fiber sensors

    Science.gov (United States)

    Sato, Tadanobu; Honda, Riki; Shibata, Shunjiro; Takegawa, Naoki

    2001-08-01

    This paper presents a device to measure the dynamic horizontal shear strain of the ground during earthquake. The proposed device consists of a bronze plate with fiber Bragg grating sensors attached on it. The device is vertically installed in the ground, and horizontal shear strain of the ground is measured as deflection angle of the plate. Employment of optical fiber sensors makes the proposed device simple in mechanism and highly durable, which makes it easy to install our device in the ground. We conducted shaking table tests using ground model to verify applicability of the proposed device.

  18. Low frequency and low temperature behavior of ZnO-based varistor by ac impedance measurements

    Science.gov (United States)

    Al Abdullah, K.; Bui, A.; Loubiere, A.

    1991-04-01

    This paper reports on an original work on the study of the behavior of ZnO-based varistor by ac impedance measurements. The measurements of complex impedance response to small ac signals applied to samples have been achieved in the frequency range 10-3-7×106 Hz and a temperature range -196-145 °C. In the temperature range below -120±10 °C, a complete semicircular relaxation phenomenon has been observed, which is in good agreement with the Debye model. In the temperature range above -120±10 °C, the appearance of the depression angle θ may arise from the heterogeneity of the barriers of the ceramic varistor. A Cole-Cole distribution function of the relaxation time constants was used to characterize the response of the ceramic device as a function of temperature. No observable influence in the response was introduced by either the space charge or the electrode. Using the leakage resistance measurements from the complex plane, two values of the activation energies were observed; 0.36±0.02 eV and 0.01±0.001 eV. Similarly, the boundary layer equivalent capacitance measurements detect two other energy levels: 0.06±0.005 eV and about 0 eV.

  19. Fault identification using piezoelectric impedance measurement and model-based intelligent inference with pre-screening

    Science.gov (United States)

    Shuai, Q.; Zhou, K.; Zhou, Shiyu; Tang, J.

    2017-04-01

    While piezoelectric impedance/admittance measurements have been used for fault detection and identification, the actual identification of fault location and severity remains to be a challenging topic. On one hand, the approach that uses these measurements entertains high detection sensitivity owing to the high-frequency actuation/sensing nature. On the other hand, high-frequency analysis requires high dimensionality in the model and the subsequent inverse analysis contains a very large number of unknowns which often renders the identification problem under-determined. A new fault identification algorithm is developed in this research for piezoelectric impedance/admittance based measurement. Taking advantage of the algebraic relation between the sensitivity matrix and the admittance change measurement, we devise a pre-screening scheme that can rank the likelihoods of fault locations with estimated fault severity levels, which drastically reduces the fault parameter space. A Bayesian inference approach is then incorporated to pinpoint the fault location and severity with high computational efficiency. The proposed approach is examined and validated through case studies.

  20. Digital PIV Measurements of Acoustic Particle Displacements in a Normal Incidence Impedance Tube

    Science.gov (United States)

    Humphreys, William M., Jr.; Bartram, Scott M.; Parrott, Tony L.; Jones, Michael G.

    1998-01-01

    Acoustic particle displacements and velocities inside a normal incidence impedance tube have been successfully measured for a variety of pure tone sound fields using Digital Particle Image Velocimetry (DPIV). The DPIV system utilized two 600-mj Nd:YAG lasers to generate a double-pulsed light sheet synchronized with the sound field and used to illuminate a portion of the oscillatory flow inside the tube. A high resolution (1320 x 1035 pixel), 8-bit camera was used to capture double-exposed images of 2.7-micron hollow silicon dioxide tracer particles inside the tube. Classical spatial autocorrelation analysis techniques were used to ascertain the acoustic particle displacements and associated velocities for various sound field intensities and frequencies. The results show that particle displacements spanning a range of 1-60 microns can be measured for incident sound pressure levels of 100-130 dB and for frequencies spanning 500-1000 Hz. The ability to resolve 1 micron particle displacements at sound pressure levels in the 100 dB range allows the use of DPIV systems for measurement of sound fields at much lower sound pressure levels than had been previously possible. Representative impedance tube data as well as an uncertainty analysis for the measurements are presented.

  1. Impedance measurement for microstructure characterization and internal surface estimation of macroporous silicon

    Energy Technology Data Exchange (ETDEWEB)

    RoyChaudhuri, C. [Department of Electronics and Telecommunication Engineering, Bengal Engineering and Science University, Shibpur, Botanic Garden, Howrah 711103 (India); Jana, M.; Bandopadhyay, N.R. [School of Materials Science and Engineering, Bengal Engineering and Science University, Shibpur, Botanic Garden, Howrah 711103 (India)

    2010-09-15

    In this paper, a simple and convenient method based on impedance measurement has been proposed for the first time to evaluate the average porosity, pore radius, and internal surface area of macroporous silicon structure fabricated by electrochemical method. The porosity and the average pore radius have been obtained by developing a geometrical model and applying the generalized effective medium approximation theory to the dc and ac impedance measurement of both unoxidized and thermally oxidized macroporous silicon. The internal surface area per unit volume is then computed from the porosity and the pore radius using the same model. The method has been applied to a wide range of porosity from 30 to 58% fabricated on p-type <100> silicon with a resistivity of 10-20 {omega} cm. Experimental verification of porosity, mean pore radius, and internal surface area have been performed by standard gravimetric technique and by top-view and cross-section SEM imaging, respectively. A typical mean pore radius, porosity, and internal surface area of a macroporous silicon sample has been obtained to be 1.52 {mu}m, 54.2%, and 3565.7 cm{sup 2}/cm{sup 3}, respectively, from the impedance measurement and 1.5 {mu}m, 55%, and 3666.7 cm{sup 2}/cm{sup 3} from SEM and gravimetric analysis which shows that the results are within 2% of the values obtained by conventional methods. The advantages of this method over the other recently reported techniques for similar characterization have been discussed. (Abstract Copyright [2010], Wiley Periodicals, Inc.)

  2. Non-invasive measurements of cardiac output in atrial fibrillation: Inert gas rebreathing and impedance cardiography

    DEFF Research Database (Denmark)

    Osbak, Philip S; Henriksen, Jens Henrik Sahl; Kofoed, Klaus F

    2011-01-01

    Abstract Background. Atrial fibrillation (AF) is associated with significant morbidity and mortality. To test the effect of interventions, knowledge of cardiac output (CO) is important. However, the irregular heart rate might cause some methods for determination of CO to have inherent weaknesses....... Objective. To assess the validity of these methods in AF, a new inert gas rebreathing device and impedance cardiography was tested with echocardiography as reference. Methods. Using a cross-sectional design, 127 patients with AF and 24 in SR were consecutively recruited. Resting CO was measured using inert...

  3. Impedance simulations and measurements on the LHC collimators with embedded beam position monitors

    CERN Document Server

    Biancacci, N; Kuczerowski, J; Métral,; Mounet, N; Salvant, B; Mostacci, A; Frasciello, O; Zobov, M

    2017-01-01

    The LHC collimation system is a critical element for the safe operation of the LHC machine. The necessity of fast accurate positioning of the collimator’s jaws, recently introduced the need to have button beam position monitors directly embedded in the jaws extremities of the LHC tertiary collimators and some secondary collimators. This addition led to a new design of these collimators including ferrites to damp higher order modes instead of rf fingers. In this work we will present the impedance bench measurements and simulations on a TCT (Transverse Tertiary Collimator) prototype including estimations for beam stability for the LHC.

  4. Impedance simulations and measurements on the LHC collimators with embedded beam position monitors

    Directory of Open Access Journals (Sweden)

    N. Biancacci

    2017-01-01

    Full Text Available The LHC collimation system is a critical element for the safe operation of the LHC machine. The necessity of fast accurate positioning of the collimator’s jaws, recently introduced the need to have button beam position monitors directly embedded in the jaws extremities of the LHC tertiary collimators and some secondary collimators. This addition led to a new design of these collimators including ferrites to damp higher order modes instead of rf fingers. In this work we will present the impedance bench measurements and simulations on a TCT (Transverse Tertiary Collimator prototype including estimations for beam stability for the LHC.

  5. Impedance measurements on a spiral-wound nickel/metal hydride cell cycled in a simulated Leo orbit

    Science.gov (United States)

    Reid, Margaret A.

    1993-01-01

    A spiral-wound size C cell was cycled at 25 C in a low earth orbit (LEO) regime at 50 percent depth of discharge (DOD) with approximately five percent over-charge. The nominal capacity was 3.5 AH. The cell was cycled for 2000 cycles. Capacity checks and impedance measurements over the complete range of state of charge were made upon receipt and after 500, 1000, and 2000 cycles. The capacity of the cell was essentially unchanged until after the impedance measurements at 2000 cycles. Only small changes in the impedance parameters were observed, but there was somewhat more scatter in the data after 2000 cycles. When the cell was returned to LEO cycling after 2000 cycles, only 38 percent of the capacity could be obtained. It is believed that the cell failed because of an equipment failure at the end of the final impedance measurements which allowed an over-discharge.

  6. Textrode-enabled transthoracic electrical bioimpedance measurements - towards wearable applications of impedance cardiography

    Directory of Open Access Journals (Sweden)

    Juan Carlos Márquez Ruiz

    2013-10-01

    Full Text Available During the last decades the use of Electrical Bioimpedance (EBI in the medical field has been subject of extensive research, especially since it is an affordable, harmless and non-invasive technology. In some specific applications such as body composition assessment where EBI has proven a good degree of effectiveness and reliability, the use of textile electrodes and measurement garments have shown a good performance and reproducible results. Impedance Cardiography (ICG is another modality of EBI that can benefit from the implementation and use of wearable sensors. ICG technique is based on continuous impedance measurements of a longitudinal segment across the thorax taken at a single frequency. The need for specific electrode placement on the thorax and neck can be easily ensured with the use of a garment with embedded textile electrodes, textrodes. The first step towards the implementation of ICG technology into a garment is to find out if ICG measurements with textile sensors give a good enough quality of the signal to allow the estimation of the fundamental ICG parameters. In this work, the measurement performance of a 2-belt set with incorporated textrodes for thorax and neck was compared against ICG measurements obtained with Ag/AgCl electrodes. The analysis was based on the quality of the fundamental ICG signals (∆Z, dZ/dt and ECG, systolic time intervals and other ICG parameters. The obtained results indicate the feasibility of using textrodes for ICG measurements with consistent measurements and relatively low data dispersion. Thus, enabling the development of measuring garments for ICG measurements.

  7. Multifrequency impedance measurement technique for wireless characterization of microbiological cell cultures

    Science.gov (United States)

    Wissenwasser, J.; Vellekoop, M. J.; Kapferer, W.; Lepperdinger, G.; Heer, R.

    2011-11-01

    An impedance measurement system with probe signal frequencies up to 50 kHz with AC-probe voltages below 30 mV rms was integrated for wireless and battery-free monitoring of microbiological cell cultures. The here presented modular design and the use of state-of-the-art components greatly eases adoptions to a wide range of biotechnological applications without the need of bulky LCR-meters or potentiostats. The device had a power consumption of less than 2.5 mA at a 3.3 V single power supply and worked trouble-free within the humid environment of a cell culture incubator. Measurements on lumped RC-elements showed an error of less than 1% for absolute values and less than 1° regarding the phase of the complex impedance. The performance of sensor devices with interdigitated electrode structures for the measurement of adherent cell cultures was tested in the presence of phosphate-buffered saline solution in the humid atmosphere of an incubator for biological cell cultures.

  8. Multifrequency impedance measurement technique for wireless characterization of microbiological cell cultures.

    Science.gov (United States)

    Wissenwasser, J; Vellekoop, M J; Kapferer, W; Lepperdinger, G; Heer, R

    2011-11-01

    An impedance measurement system with probe signal frequencies up to 50 kHz with AC-probe voltages below 30 mV rms was integrated for wireless and battery-free monitoring of microbiological cell cultures. The here presented modular design and the use of state-of-the-art components greatly eases adoptions to a wide range of biotechnological applications without the need of bulky LCR-meters or potentiostats. The device had a power consumption of less than 2.5 mA at a 3.3 V single power supply and worked trouble-free within the humid environment of a cell culture incubator. Measurements on lumped RC-elements showed an error of less than 1% for absolute values and less than 1° regarding the phase of the complex impedance. The performance of sensor devices with interdigitated electrode structures for the measurement of adherent cell cultures was tested in the presence of phosphate-buffered saline solution in the humid atmosphere of an incubator for biological cell cultures.

  9. Measurement of noise and impedance of dry and wet textile electrodes, and textile electrodes with hydrogel.

    Science.gov (United States)

    Puurtinen, Merja M; Komulainen, Satu M; Kauppinen, Pasi K; Malmivuo, Jaakko A V; Hyttinen, Jari A K

    2006-01-01

    Textile sensors, when embedded into clothing, can provide new ways of monitoring physiological signals, and improve the usability and comfort of such monitoring systems in the areas of medical, occupational health and sports. However, good electrical and mechanical contact between the electrode and the skin is very important, as it often determines the quality of the signal. This paper introduces a study where the properties of dry textile electrodes, textile electrodes moistened with water, and textile electrodes covered with hydrogel were studied with five different electrode sizes. The aim was to study how the electrode size and preparation of the electrode (dry electrode/wet electrode/electrode covered with hydrogel membrane) affect the measurement noise, and the skin-electrode impedance. The measurement noise and skin-electrode impedance were determined from surface biopotential measurements. These preliminary results indicate that noise level increases as the electrode size decreases. The noise level is high in dry textile electrodes, as expected. Yet, the noise level of wet textile electrodes is quite low and similar to that of textile electrodes covered with hydrogel. Hydrogel does not seem to improve noise properties, however it may have effects on movement artifacts. Thus, it is feasible to use textile embedded sensors in physiological monitoring applications when moistening or hydrogel is applied.

  10. Validation of bioelectrical-impedance analysis as a measurement of change in body composition in obesity

    Energy Technology Data Exchange (ETDEWEB)

    Kushner, R.F.; Kunigk, A.; Alspaugh, M.; Andronis, P.T.; Leitch, C.A.; Schoeller, D.A. (Univ. of Chicago, IL (USA))

    1990-08-01

    The bioelectrical-impedance-analysis (BIA) method accurately measures body composition in weight-stable subjects. This study validates the use of BIA to measure change in body composition. Twelve obese females underwent weight loss at a mean rate of 1.16 kg/wk. Body composition was measured by deuterium oxide dilution (D2O), BIA, and skinfold anthropometry (SFA) at baseline and at 5% decrements in weight. Highly significant correlations were obtained between D2O and BIA (r = 0.971) and between D2O and SFA (r = 0.932). Overall, BIA predicted change in fat-free mass with greater accuracy (to 0.4 kg) and precision (+/- 1.28 kg) than did anthropometry (to 0.8 kg and +/- 2.58 kg, respectively). We conclude that BIA is a useful clinical method for measuring change in body composition.

  11. Real-Time Low Frequency Impedance Measurements for Determination of Hydrogen Content in Pipeline Steel

    Science.gov (United States)

    Lasseigne, A. N.; Koenig, K.; Olson, D. L.; Jackson, J. E.; Mishra, B.; McColskey, J. D.

    2009-03-01

    The assessment of hydrogen content in pipeline steel is an essential requirement to monitor loss of pipe integrity with time and to prevent failures. The use of pipeline steels of increasing strength significantly reduces the threshold hydrogen concentration for hydrogen cracking. Cathodic protection and corrosion processes both contribute to accumulation of hydrogen as a function of time, which may eventually meet the cracking criteria. New and unique methodologies based on electronic property measurements offer the pipeline industry advanced non-destructive tools to provide quantified in-situ hydrogen content measurements in real-time. The use of low frequency impedance measurements as a non-contact sensor has been demonstrated for real-time determination of hydrogen content in coated pipeline steel specimens in the laboratory. Scale-up to field measurements is in progress, and the development and use of a field sensor are discussed.

  12. Practical application of the Kramers-Kronig transformation on impedance measurements in solid state electrochemistry

    NARCIS (Netherlands)

    Boukamp, Bernard A.

    1993-01-01

    A method is presented for executing the Kramers-Kronig transforms of electrochemical impedance data on a computer. Attention is paid to the extrapolation techniques for impedance data with a limited frequency range. It is shown that impedance spectra of systems with blocking electrodes, exhibiting a

  13. Body fat measurement by bioelectrical impedance and air displacement plethysmography: a cross-validation study to design bioelectrical impedance equations in Mexican adults

    Directory of Open Access Journals (Sweden)

    Valencia Mauro E

    2007-08-01

    Full Text Available Abstract Background The study of body composition in specific populations by techniques such as bio-impedance analysis (BIA requires validation based on standard reference methods. The aim of this study was to develop and cross-validate a predictive equation for bioelectrical impedance using air displacement plethysmography (ADP as standard method to measure body composition in Mexican adult men and women. Methods This study included 155 male and female subjects from northern Mexico, 20–50 years of age, from low, middle, and upper income levels. Body composition was measured by ADP. Body weight (BW, kg and height (Ht, cm were obtained by standard anthropometric techniques. Resistance, R (ohms and reactance, Xc (ohms were also measured. A random-split method was used to obtain two samples: one was used to derive the equation by the "all possible regressions" procedure and was cross-validated in the other sample to test predicted versus measured values of fat-free mass (FFM. Results and Discussion The final model was: FFM (kg = 0.7374 * (Ht2 /R + 0.1763 * (BW - 0.1773 * (Age + 0.1198 * (Xc - 2.4658. R2 was 0.97; the square root of the mean square error (SRMSE was 1.99 kg, and the pure error (PE was 2.96. There was no difference between FFM predicted by the new equation (48.57 ± 10.9 kg and that measured by ADP (48.43 ± 11.3 kg. The new equation did not differ from the line of identity, had a high R2 and a low SRMSE, and showed no significant bias (0.87 ± 2.84 kg. Conclusion The new bioelectrical impedance equation based on the two-compartment model (2C was accurate, precise, and free of bias. This equation can be used to assess body composition and nutritional status in populations similar in anthropometric and physical characteristics to this sample.

  14. Simulation method for cardiac stroke volume estimation by intracardiac electrical impedance measurement.

    Science.gov (United States)

    Barak, C; Leviatan, Y; Inbar, G F; Hoekstein, K N

    1992-09-01

    Using the electrical impedance measurement technique to investigate stroke volume estimation, three models of the ventricle were simulated. A four-electrode impedance catheter was used; two electrodes to set up an electric field in the model and the other two to measure the potential difference. A new approach, itself an application of the quasi-static case of a method used to solve electromagnetic field problems, was used to solve the electric field in the model. The behaviour of the estimation is examined with respect to the electrode configuration on the catheter and to catheter location with respect to the ventricle walls. Cardiac stroke volume estimation was found to be robust to catheter location generating a 10 per cent error for an offset of 40 per cent of the catheter from the chamber axis and rotation of 20 degrees with respect to the axis. The electrode configuration has a dominant effect on the sensitivity and accuracy of the estimation. Certain configurations gave high accuracy, whereas in others high sensitivity was found with lower accuracy. This led to the conclusion that the electrode configuration should be carefully chosen according to the desired criteria.

  15. DC current and AC impedance measurements on boron-doped single crystalline diamond films

    Energy Technology Data Exchange (ETDEWEB)

    Ye, Haitao; Gaudin, O.; Jackman, R.B. [Department of Electronic and Electrical Engineering, University College London, Torrington Place, London WC1E 7JE (United Kingdom); Muret, P.; Gheeraert, E. [Laboratoire d' Etudes des Proprietes Electroniques des Solides, BP166, 38042 Grenoble Cedex 9 (France)

    2003-09-01

    In this paper, we report the first measurement of impedance on boron-doped single crystalline diamond films from 0.1 Hz to 10 MHz with the temperature ranging from -100 C up to 300 C. The Cole-Cole (Z' via Z{sup ''}) plots are well fitted to a RC parallel circuit model and the equivalent Resistance and Capacitance for the diamond films have been estimated using the Zview curve fitting. The results show only one single semicircle response at each temperature measured. It was found that the resistance decreases from 70 G{omega} at -100 C to 5 k{omega} at 300 C. The linear curve fitting from -100 C to 150 C shows the sample has an activation energy of 0.37 eV, which is consistent with the theoretical value published of this kind of material. The equivalent capacitance is maintained at the level of pF up to 300 C suggesting that no grain boundaries are being involved, as expected from a single crystal diamond. The activation energy from the dc current-temperature curves is 0.36 eV, which is consistent with the value from ac impedance. The potential of this under-used technique for diamond film analysis will be discussed. (copyright 2003 WILEY-VCH Verlag GmbH and Co. KGaA, Weinheim) (orig.)

  16. Gastric emptying patterns of a liquid meal in newborn infants, measured by epigastric impedance

    DEFF Research Database (Denmark)

    Lange, Aksel; Funch-Jensen, Peter; Thommesen, Peter

    1997-01-01

      Epigastric impedance was used to measure patterns of the gastric emptying of a liquid non-caloric meal (5 ml water/kg) in newborn infants. The emptying patterns consisted of two components, theemptying signal - the DC component - and a phasic 3 cycle per minutes (CPM) signal - the AC component....... Phasic 3 CPM signal was also seen during the fasting state. Measurements were erformed in thirty healthy infants. Twenty-six mature infants were examined in the first eight days of life, and four preterm infants were examined within 6 weeks after birth. For the emptying signal the median half emptying.......A periodic change of the impedance signal, the phasic 3 CPM signal, was observed after a meal in 24 of the infants. The median frequency was 3.03 CPM in 20 mature and 2.93 CPM in 4 preterminfants. In 9 infants a phasic 3 CPM signal was observed during fasting state. The median frequency was 2.9 CPM...

  17. Health monitoring of a continuous rigid frame bridge based on PZT impedance and strain measurements

    Science.gov (United States)

    Zhang, Junbing; Zhu, Hongping; Wang, Dansheng; He, Bo; Zhou, Huaqiang

    2009-07-01

    Critical civil infrastructures such as bridges, dams, and pipelines present a major investment and their safety and security affect the life of citizens and national economic development. So it is very important for engineers and researchers to monitor their integrity while in operation and throughout. In recent years, the piezoelectric-ceramic (PZT) patches, which serve both as impedance sensors and actuators, have been increasingly used for structural health monitoring. This paper presents an impedance-based method, which utilizes the electro-mechanical coupling property of PZT sensors. There are a lot of advantages of this method, such as not based on any physical models, sensitive to tiny damage for its high frequency characteristics. An engineering application of this method for health monitoring of a continuous rigid frame bridge is implemented in this study. Some PZT active sensors are embedded into critical sections of the continuous rigid-frame box beam. The electrical admittances of these distributed PZT sensors are measured when the bridge is constructing or suffering from operational loads. For comparison, strain gauges are arranged in adjacent regions of these PZT sensors to obtain the strains of concrete around them at the same time. Based on the admittance sigatures obtained form PZT sensors and the strain measurements of concrete around them, the health status of the bridge is monitored and evaluated successfully.

  18. Gastric emptying patterns of a liquid meal in newborn infants, measured by epigastric impedance

    DEFF Research Database (Denmark)

    Lange, Aksel; Funch-Jensen, Peter; Thommesen, Peter;

    1997-01-01

      Epigastric impedance was used to measure patterns of the gastric emptying of a liquid non-caloric meal (5 ml water/kg) in newborn infants. The emptying patterns consisted of two components, theemptying signal - the DC component - and a phasic 3 cycle per minutes (CPM) signal - the AC component....... Phasic 3 CPM signal was also seen during the fasting state. Measurements were erformed in thirty healthy infants. Twenty-six mature infants were examined in the first eight days of life, and four preterm infants were examined within 6 weeks after birth. For the emptying signal the median half emptying.......A periodic change of the impedance signal, the phasic 3 CPM signal, was observed after a meal in 24 of the infants. The median frequency was 3.03 CPM in 20 mature and 2.93 CPM in 4 preterminfants. In 9 infants a phasic 3 CPM signal was observed during fasting state. The median frequency was 2.9 CPM...

  19. Improvement Design of Biochip Towards High Stable Bioparticle Detection Utilizing Dielectrophoresis Impedance Measurement

    Institute of Scientific and Technical Information of China (English)

    Huang Haibo; Qian Cheng; Li Xiangpeng; Chen Liguo; Xu Wenkui; Zheng Liang; Sun Lining

    2015-01-01

    Dielectrophoresis impedance measurement (DEPIM ) is a powerful tool for bioparticle detection due to its advantages of high efficiency ,label-free and low costs .However ,the strong electric field may decrease the viabili-ty of the bioparticle ,thus leading to instability of impedance measurement .A new design of biochip is presented with high stable bioparticle detection capabilities by using both negative dielectrophoresis (nDEP) and traveling wave dielectrophoresis (twDEP) .In the biochip ,a spiral electrode is arranged on the top of channel ,while a detec-tor is arranged on the bottom of the channel .The influence factors on the DEP force and twDEP force are investi-gated by using the basic principle of DEP ,based on which ,the relationship between Clausius-Mossotti (CM) fac-tor and the frequency of electric field is obtained .The two-dimensional model of the biochip is built by using Com-sol Multiphysics .Electric potential distribution ,force distribution and particle trajectory in the channel are then obtained by using the simulation model .Finally ,both the simulations and experiments are performed to demon-strate that the new biochip can enhance the detection efficiency and reduce the negative effects of electric field on the bioparticles .

  20. In vivo bioimpedance measurement of healthy and ischaemic rat brain: implications for stroke imaging using electrical impedance tomography.

    Science.gov (United States)

    Dowrick, T; Blochet, C; Holder, D

    2015-06-01

    In order to facilitate the imaging of haemorrhagic and ischaemic stroke using frequency difference electrical impedance tomography (EIT), impedance measurements of normal and ischaemic brain, and clotted blood during haemorrhage, were gathered using a four-terminal technique in an in vivo animal model, a first for ischaemic measurements. Differences of 5-10% in impedance were seen between the frequency spectrums of healthy and ischaemic brain, over the frequency range 0-3 kHz, while the spectrum of blood was predominately uniform. The implications of imaging blood/ischaemia in the brain using electrical impedance tomography are discussed, supporting the notion that it will be possible to differentiate stroke from haemorrhage.

  1. A comparison of systolic time intervals measured by impedance cardiography and carotid pulse tracing

    DEFF Research Database (Denmark)

    Mehlsen, J; Bonde, J; Rehling, Michael;

    1990-01-01

    .001) and found that left ventricular ejection times were longer when determined by the carotid technique (p less than 0.01). We found a significant correlation between drug-induced changes in STI-variables measured by the two methods (p less than 0.001). Both methods had a high degree of reproducibility......The purpose of this study was to compare the systolic time intervals (STI) obtained by impedance cardiography and by the conventional carotid technique. This comparison was done with respect to: 1) correlations between variables obtained by the two methods, 2) ability to reflect drug......-induced changes, 3) reliability in terms of reproducibility and 4) heart rate dependency of the variables measured. The study included 25 unmedicated patients with ischaemic heart disease and 36 healthy subjects. We obtained significant correlations between STI-variables measured by the two methods (p less than 0...

  2. Earthquake Ground Motion Measures for Seismic Response Evaluation of Structures

    Energy Technology Data Exchange (ETDEWEB)

    Cho, In-Kil; Ahn, Seong-Moon; Choun, Young-Sun; Seo, Jeong-Moon

    2007-03-15

    This study used the assessment results of failure criteria - base shear, story drift, top acceleration and top displacement - for a PSC containment building subjected to 30 sets of near-fault ground motions to evaluate the earthquake ground motion intensity measures. Seven intensity measures, peak ground acceleration(PGA), peak ground velocity(PGV), spectral acceleration(Sa), velocity(Sv), spectrum intensity for acceleration(SIa), velocity(SIv) and displacement(SId), were used to represent alternative ground motion. The regression analyses of the failure criteria for a PSC containment building were carried out to evaluate a proper intensity measure by using two regression models and seven ground motion parameters. The regression analysis results demonstrate the correlation coefficients of the failure criteria in terms of the candidate IM. From the results, spectral acceleration(Sa) is estimated as the best parameter for a evaluation of the structural safety for a seismic PSA.

  3. Dynamic tire pressure sensor for measuring ground vibration.

    Science.gov (United States)

    Wang, Qi; McDaniel, James Gregory; Wang, Ming L

    2012-11-07

    This work presents a convenient and non-contact acoustic sensing approach for measuring ground vibration. This approach, which uses an instantaneous dynamic tire pressure sensor (DTPS), possesses the capability to replace the accelerometer or directional microphone currently being used for inspecting pavement conditions. By measuring dynamic pressure changes inside the tire, ground vibration can be amplified and isolated from environmental noise. In this work, verifications of the DTPS concept of sensing inside the tire have been carried out. In addition, comparisons between a DTPS, ground-mounted accelerometer, and directional microphone are made. A data analysis algorithm has been developed and optimized to reconstruct ground acceleration from DTPS data. Numerical and experimental studies of this DTPS reveal a strong potential for measuring ground vibration caused by a moving vehicle. A calibration of transfer function between dynamic tire pressure change and ground acceleration may be needed for different tire system or for more accurate application.

  4. Transfer impedance simulation and measurement methods to analyse shielding behaviour of HV cables used in Electric-Vehicles and Hybrid-Electric-Vehicles

    Science.gov (United States)

    Mushtaq, Abid; Frei, Stephan

    2016-09-01

    In the power drive system of the Electric Vehicles (EVs) and Hybrid Electric Vehicles (HEVs), High Voltage (HV) cables play a major role in evaluating the EMI of the whole system. Transfer impedance (ZT) is the most commonly used performance parameter for the HV cable. To analyse and design HV cables and connectors with better shielding effectiveness (SE), appropriate measurement and simulation methods are required. In this paper, Ground Plate Method (GPM) with improvements has been proposed to measure ZT. Use of low-frequency ferrites to avoid ground-loop effects has also been investigated. Additionally, a combination of analytical model with a circuit model has been implemented to simulate limitations (frequency response) of the test setup. Also parametrical studies using the analytical model have been performed to analyse the shielding behaviour of HV cables.

  5. Effects of metoclopramide on gastric motility measured by short-term bio-impedance

    Institute of Scientific and Technical Information of China (English)

    María-Raquel Huerta-Franco; Miguel Vargas-Luna; Kathleen M Capaccione; Etna Ya(n)ez-Roldán; Ulises Hernández-Ledezma; Ismael Morales-Mata; Teodoro Córdova-Fraga

    2009-01-01

    AIM: To analyze the accuracy of short-term bio-impedance as a means of measuring gastric motility.METHODS: We evaluated differences in the shortterm electrical bio-impedance signal from the gastric region in the following conditions: (1) fasting state,(2) after the administration of metoclopramide (a drug that induces an increase in gastric motility) and (3) after food ingestion in 23 healthy volunteers. We recorded the real component of the electrical impedance signal from the gastric region for 1000 s. We performed a Fast Fourier Transform (FFT) on this data and then compared the signal among the fasting, medicated, and postprandial conditions using the median of the area under the curve, the relative area under the curve and the main peak activity. RESULTS: The median of the area under the curve of the frequency range in the region between 2-8 cycles per minute (cpm) decreased from 4.7 cpm in the fasting condition to 4.0 cpm in the medicated state ( t = 3.32, P = 0.004). This concurred with the decrease seen in the relative area under the FFT curve in the region from 4 to 8 cpm from 38.3% to 26.6% ( t = 2.81, P = 0.012) and the increase in area in the region from 2to 4 cpm from 22.4% to 27.7%, respectively ( t = -2.5,P = 0.022). Finally the main peak position also decreased in the region from 2 to 8 cpm. Main peak activity in the fasting state was 4.72 cpm and declined to 3.45 cpmin the medicated state ( t = 2.47, P = 0.025). There was a decrease from the fasting state to the postprandial state at 3.02 cpm ( t = 4.0, P = 0.0013).CONCLUSION: Short-term electrical bio-impedance can assess gastric motility changes in individuals experiencing gastric stress by analyzing the area medians and relative areas under the FFT curve.

  6. Effects of metoclopramide on gastric motility measured by short-term bio-impedance

    Science.gov (United States)

    Huerta-Franco, María-Raquel; Vargas-Luna, Miguel; Capaccione, Kathleen M; Yañez-Roldán, Etna; Hernández-Ledezma, Ulises; Morales-Mata, Ismael; Córdova-Fraga, Teodoro

    2009-01-01

    AIM: To analyze the accuracy of short-term bio-impedance as a means of measuring gastric motility. METHODS: We evaluated differences in the short-term electrical bio-impedance signal from the gastric region in the following conditions: (1) fasting state, (2) after the administration of metoclopramide (a drug that induces an increase in gastric motility) and (3) after food ingestion in 23 healthy volunteers. We recorded the real component of the electrical impedance signal from the gastric region for 1000 s. We performed a Fast Fourier Transform (FFT) on this data and then compared the signal among the fasting, medicated, and postprandial conditions using the median of the area under the curve, the relative area under the curve and the main peak activity. RESULTS: The median of the area under the curve of the frequency range in the region between 2-8 cycles per minute (cpm) decreased from 4.7 cpm in the fasting condition to 4.0 cpm in the medicated state (t = 3.32, P = 0.004). This concurred with the decrease seen in the relative area under the FFT curve in the region from 4 to 8 cpm from 38.3% to 26.6% (t = 2.81, P = 0.012) and the increase in area in the region from 2 to 4 cpm from 22.4% to 27.7%, respectively (t = -2.5, P = 0.022). Finally the main peak position also decreased in the region from 2 to 8 cpm. Main peak activity in the fasting state was 4.72 cpm and declined to 3.45 cpm in the medicated state (t = 2.47, P = 0.025). There was a decrease from the fasting state to the postprandial state at 3.02 cpm (t = 4.0, P = 0.0013). CONCLUSION: Short-term electrical bio-impedance can assess gastric motility changes in individuals experiencing gastric stress by analyzing the area medians and relative areas under the FFT curve. PMID:19824108

  7. Lung recruitment and endotracheal suction in ventilated preterm infants measured with electrical impedance tomography.

    Science.gov (United States)

    Hough, Judith L; Shearman, Andrew D; Liley, Helen; Grant, Caroline A; Schibler, Andreas

    2014-11-01

    Although suctioning is a standard airway maintenance procedure, there are significant associated risks, such as loss of lung volume due to high negative suction pressures. This study aims to assess the extent and duration of change in end-expiratory level (EEL) resulting from endotracheal tube (ETT) suction and to examine the relationship between EEL and regional lung ventilation in ventilated preterm infants with respiratory distress syndrome. A prospective observational clinical study of the effect of ETT suction on 20 non-muscle-relaxed preterm infants with respiratory distress syndrome (RDS) on conventional mechanical ventilation was conducted in a neonatal intensive care unit. Ventilation distribution was measured with regional impedance amplitudes and EEL using electrical impedance tomography. ETT suction resulted in a significant increase in EEL post-suction (P suction, suggesting heterogeneity. Tidal volume was significantly lower in volume-guarantee ventilation compared with pressure-controlled ventilation (P = 0.04). ETT suction in non-muscle-relaxed and ventilated preterm infants with RDS results in significant lung volume increase that is maintained for at least 90 min. Regional differences in distribution of ventilation with ETT suction suggest that the behaviour of the lung is heterogeneous in nature. © 2014 The Authors. Journal of Paediatrics and Child Health © 2014 Paediatrics and Child Health Division (Royal Australasian College of Physicians).

  8. Measurement of lean body mass using bioelectrical impedance analysis: a consideration of the pros and cons.

    Science.gov (United States)

    Sergi, Giuseppe; De Rui, Marina; Stubbs, Brendon; Veronese, Nicola; Manzato, Enzo

    2016-08-27

    The assessment of body composition has important applications in the evaluation of nutritional status and estimating potential health risks. Bioelectrical impedance analysis (BIA) is a valid method for the assessment of body composition. BIA is an alternative to more invasive and expensive methods like dual-energy X-ray absorptiometry, computerized tomography, and magnetic resonance imaging. Bioelectrical impedance analysis is an easy-to-use and low-cost method for the estimation of fat-free mass (FFM) in physiological and pathological conditions. The reliability of BIA measurements is influenced by various factors related to the instrument itself, including electrodes, operator, subject, and environment. BIA assumptions beyond its use for body composition are the human body is empirically composed of cylinders, FFM contains virtually all the water and conducting electrolytes in the body, and its hydration is constant. FFM can be predicted by BIA through equations developed using reference methods. Several BIA prediction equations exist for the estimation of FFM, skeletal muscle mass (SMM), or appendicular SMM. The BIA prediction models differ according to the characteristics of the sample in which they have been derived and validated in addition to the parameters included in the multiple regression analysis. In choosing BIA equations, it is important to consider the characteristics of the sample in which it has been developed and validated, since, for example, age- and ethnicity-related differences could sensitively affect BIA estimates.

  9. Bench measurements of the LHC injection kicker low frequency impedance properties

    CERN Document Server

    Caspers, Friedhelm; CERN. Geneva. SPS and LHC Division

    2002-01-01

    The LHC injection kicker contains a ceramic tube with inside printed metallic strips as a RF bypass in order to minimise the beam coupling impedance. These strips are capacitively coupled at one side to avoid eddy current during kicker transients. Experimentally it was found already earlier, using bench techniques, that in the region between 10 and 30 MHz certain resonances and thus peaks in the coupling impedance occur, related to the transition of the image current from the “cold conductor" to the bypass strips. The presence of these resonances has been reconfirmed as well as their properties. A practical method for reducing their influence by attaching lossy ferrite rings to the ends of the ceramic pipe is proposed and has partly been tested. As the present measurements were done on a mock-up for this RF bypass, which has limited validity towards higher frequencies, a full scale test should be repeated, once the first prototype of the 3 meter long ceramic chamber with printed bypass strips is ava...

  10. The measurement of water transport in porous materials using impedance spectroscopy

    Energy Technology Data Exchange (ETDEWEB)

    Ball, R J; Allen, G C [Interface Analysis Centre, University of Bristol, Oldbury House, 121 St Michael' s, Hill, Bristol, BS2 8BS (United Kingdom)

    2010-03-17

    This paper describes the application of electrical measurements to monitor the extraction (movement of water from the mortar) of water from calcium lime, natural hydraulic lime and Portland cement mortars placed on an adsorbent brick substrate. Impedance measurements were used to identify the changes in bulk resistance of the mortar. A model has been developed combining sharp front theory and Boltzmann's distribution law of statistical thermodynamics to identify the point at which no further absorption of water into the brick occurs. A linear relationship was found between the exponential of bulk resistance and the square root of time during dewatering. A change in gradient was attributed to the end of dewatering.

  11. Electrical Conductivity of Synthetic Quartz Crystals at High Temperature and Pressure from Complex Impedance Measurements

    Institute of Scientific and Technical Information of China (English)

    王多君; 李和平; 刘丛强; 易丽; 丁东业; 苏根利; 张卫刚

    2002-01-01

    An electrical conductivity measurement system under high-pressure conditions with a multi-anvil high-pressure apparatus by an ac complex impedance method was set up. With this system, we have successfully measured the electrical conductivity of synthetic quartz under pressure up to approximately 1.0 GPa in the temperature range 661-987K. The values of electrical conductivity decrease with the increasing pressure and increase with the increasing temperature. The activation enthalpies for the α-quartz crystals are 1.10-1.28eV. The electrical conductivity of α-quartz is ionic, with Na ions moving in channels parallel to the c-axis being the predominant current carrier.

  12. Sensitivity analysis of magnetic field measurements for magnetic resonance electrical impedance tomography (MREIT)

    DEFF Research Database (Denmark)

    Göksu, Cihan; Scheffler, Klaus; Ehses, Philipp

    2017-01-01

    : The efficiency simulations and experimental results are in good agreement. When using optimal parameters, DBz,c can be reliably measured in the phantom even at injected current strengths of 1 mA or lower for both sequence types. The importance of using proper crusher gradient selection on the phase evolution...... in a MESE experiment is also demonstrated. Conclusion: The efficiencies observed with the optimized sequence parameters will likely render in-vivo human brain MREIT feasible.......Purpose: Clinical use of magnetic resonance electrical impedance tomography (MREIT) still requires significant sensitivity improvements. Here, the measurement of the current-induced magnetic field (DBz,c) is improved using systematic efficiency analyses and optimization of multi-echo spin echo...

  13. Sensitivity analysis of magnetic field measurements for magnetic resonance electrical impedance tomography (MREIT)

    DEFF Research Database (Denmark)

    Göksu, Cihan; Scheffler, Klaus; Ehses, Philipp

    2017-01-01

    : The efficiency simulations and experimental results are in good agreement. When using optimal parameters, ΔBz,c can be reliably measured in the phantom even at injected current strengths of 1 mA or lower for both sequence types. The importance of using proper crusher gradient selection on the phase evolution...... in a MESE experiment is also demonstrated. CONCLUSION: The efficiencies observed with the optimized sequence parameters will likely render in-vivo human brain MREIT feasible. Magn Reson Med, 2017. © 2017 International Society for Magnetic Resonance in Medicine.......PURPOSE: Clinical use of magnetic resonance electrical impedance tomography (MREIT) still requires significant sensitivity improvements. Here, the measurement of the current-induced magnetic field (ΔBz,c ) is improved using systematic efficiency analyses and optimization of multi-echo spin echo...

  14. Estimation of Metabolism Characteristics for Heat-Injured Bacteria Using Dielectrophoretic Impedance Measurement Method

    Science.gov (United States)

    Amako, Eri; Enjoji, Takaharu; Uchida, Satoshi; Tochikubo, Fumiyoshi

    Constant monitoring and immediate control of fermentation processes have been required for advanced quality preservation in food industry. In the present work, simple estimation of metabolic states for heat-injured Escherichia coli (E. coli) in a micro-cell was investigated using dielectrophoretic impedance measurement (DEPIM) method. Temporal change in the conductance between micro-gap (ΔG) was measured for various heat treatment temperatures. In addition, the dependence of enzyme activity, growth capacity and membrane situation for E. coli on heat treatment temperature was also analyzed with conventional biological methods. Consequently, a correlation between ΔG and those biological properties was obtained quantitatively. This result suggests that DEPIM method will be available for an effective monitoring technique for complex change in various biological states of microorganisms.

  15. A Method of Function Space for Vertical Impedance Function of a Circular Rigid Foundation on a Transversely Isotropic Ground

    Directory of Open Access Journals (Sweden)

    Morteza Eskandari-Ghadi

    2014-06-01

    Full Text Available This paper is concerned with investigation of vertical impedance function of a surface rigid circular foundation resting on a semi-infinite transversely isotropic alluvium. To this end, the equations of motion in cylindrical coordinate system, which because of axissymmetry are two coupled equations, are converted into one partial differential equation using a method of potential function. The governing partial differential equation for the potential function is solved via implementing Hankel integral transforms in radial direction. The vertical and radial components of displacement vector are determined with the use of transformed displacement-potential function relationships. The mixed boundary conditions at the surface are satisfied by specifying the traction between the rigid foundation and the underneath alluvium in a special function space introduced in this paper, where the vertical displacements are forced to satisfy the rigid boundary condition. Through exercising these restraints, the normal traction and then the vertical impedance function are obtained. The results are then compared with the existing results in the literature for the simpler case of isotropic half-space, which shows an excellent agreement. Eventually, the impedance functions are presented in terms of dimensionless frequency for different materials. The method presented here may be used to obtain the impedance function in any other direction as well as in buried footing in layered media.

  16. Radio frequency current-voltage probe for impedance and power measurements in multi-frequency unmatched loads

    Science.gov (United States)

    Lafleur, T.; Delattre, P. A.; Booth, J. P.; Johnson, E. V.; Dine, S.

    2013-01-01

    A broad-band, inline current-voltage probe, with a characteristic impedance of 50 Ω, is presented for the measurement of voltage and current waveforms, impedance, and power in rf systems. The probe, which uses capacitive and inductive sensors to determine the voltage and current, respectively, can be used for the measurement of single or multi-frequency signals into both matched and unmatched loads, over a frequency range of about 1-100 MHz. The probe calibration and impedance/power measurement technique are described in detail, and the calibrated probe results are compared with those obtained from a vector network analyzer and other commercial power meters. Use of the probe is demonstrated with the measurement of power into an unmatched capacitively coupled plasma excited by multi-frequency tailored voltage waveforms.

  17. Radio frequency current-voltage probe for impedance and power measurements in multi-frequency unmatched loads.

    Science.gov (United States)

    Lafleur, T; Delattre, P A; Booth, J P; Johnson, E V; Dine, S

    2013-01-01

    A broad-band, inline current-voltage probe, with a characteristic impedance of 50 Ω, is presented for the measurement of voltage and current waveforms, impedance, and power in rf systems. The probe, which uses capacitive and inductive sensors to determine the voltage and current, respectively, can be used for the measurement of single or multi-frequency signals into both matched and unmatched loads, over a frequency range of about 1-100 MHz. The probe calibration and impedance/power measurement technique are described in detail, and the calibrated probe results are compared with those obtained from a vector network analyzer and other commercial power meters. Use of the probe is demonstrated with the measurement of power into an unmatched capacitively coupled plasma excited by multi-frequency tailored voltage waveforms.

  18. Magnetic resonance electrical impedance tomography for measuring electrical conductivity during electroporation.

    Science.gov (United States)

    Kranjc, M; Bajd, F; Serša, I; Miklavčič, D

    2014-06-01

    The electroporation effect on tissue can be assessed by measurement of electrical properties of the tissue undergoing electroporation. The most prominent techniques for measuring electrical properties of electroporated tissues have been voltage-current measurement of applied pulses and electrical impedance tomography (EIT). However, the electrical conductivity of tissue assessed by means of voltage-current measurement was lacking in information on tissue heterogeneity, while EIT requires numerous additional electrodes and produces results with low spatial resolution and high noise. Magnetic resonance EIT (MREIT) is similar to EIT, as it is also used for reconstruction of conductivity images, though voltage and current measurements are not limited to the boundaries in MREIT, hence it yields conductivity images with better spatial resolution. The aim of this study was to investigate and demonstrate the feasibility of the MREIT technique for assessment of conductivity images of tissues undergoing electroporation. Two objects were investigated: agar phantoms and ex vivo liver tissue. As expected, no significant change of electrical conductivity was detected in agar phantoms exposed to pulses of all used amplitudes, while a considerable increase of conductivity was measured in liver tissue exposed to pulses of different amplitudes.

  19. Determination of Cole-Cole parameters using only the real part of electrical impedivity measurements.

    Science.gov (United States)

    Miranda, David A; Rivera, S A López

    2008-05-01

    An algorithm is presented to determine the Cole-Cole parameters of electrical impedivity using only measurements of its real part. The algorithm is based on two multi-fold direct inversion methods for the Cole-Cole and Debye equations, respectively, and a genetic algorithm for the optimization of the mean square error between experimental and calculated data. The algorithm has been developed to obtain the Cole-Cole parameters from experimental data, which were used to screen cervical intra-epithelial neoplasia. The proposed algorithm was compared with different numerical integrations of the Kramers-Kronig relation and the result shows that this algorithm is the best. A high immunity to noise was obtained.

  20. [Ethrane in anaesthesia for children--measurement of cardiac output by impedance-cardiography (author's transl)].

    Science.gov (United States)

    Ottermann, U; Prister, Z

    1976-12-01

    Ethrane permits a very smooth and quick introduction of anaesthesia per inhalationem without signs of any excitation due to its physical properties. Because of its low analgesic property it was necessary to administer nitrous oxide. After the interruption of Tthrane--administration our patients awoke without any nausea or vomiting. In our study we measured stroke-volume and cardiac output during and after Ethrane anaesthesia using the IFM-Minnesota Impedance Cardiograph 304 A. In the first ten minutes of anaesthesia we found a 23 per cent-decrease of strokevolume, a 19 per cent cardiac output-decrease whereas the heartrate rose slightly. Any further significant changes of these parameters up to the end of anaesthesia were not detectable. Already two minutes after the end of Ethrane-administration all parameters had reached their initial values.

  1. Electrical impedance spectroscopy measurements to estimate the uniaxial compressive strength of a fault breccia

    Indian Academy of Sciences (India)

    Sair Kahraman; Michael Alber

    2014-10-01

    Fault breccias are usually not suitable for preparing smooth specimens or else the preparation of such specimens is tedious, time consuming and expensive. To develop a predictive model for the uniaxial compressive strength (UCS) of a fault breccia from electrical resistivity values obtained from the electrical impedance spectroscopy measurements, twenty-four samples of a fault breccia were tested in the laboratory. The UCS values were correlated with corresponding resistivity values and a strong correlation between them could not be found. However, a strong correlation was found for the samples having volumetric block proportion (VBP) of 25–75%. In addition, it was seen that VBP strongly correlated with resistivity. It was concluded that the UCS of the tested breccia can be estimated from resistivity for the samples having VBP of 25–75%.

  2. Electrical properties of rat muscle after sciatic nerve injury: Impact on surface impedance measurements assessed via finite element analysis

    Science.gov (United States)

    Ahad, M. A.; Rutkove, S. B.

    2010-04-01

    Tetrapolar surface electrical impedance methods are sensitive to changes in muscle status and can therefore provide a means for studying neuromuscular disease noninvasively. In order to better understand the relationship between surface impedance measurements and the actual muscle electrical properties, we performed measurements on 20 adult Wistar rats, 8 of which underwent sciatic nerve crush. Surface impedance measurements were performed on the left hind limb both before injury and out to 2 weeks after injury. In addition, both normal and sciatic crush animals were sacrificed and the dielectric properties of the extracted gastrocnemius muscle measured. We found that 50 kHz conductivities were greater in the animals that underwent crush than in the animals that did not. The permittivities in both directions, however, showed non-significant differences. In order to analyze the effect of these changes as well as the accompanying reduction in muscle volume, a finite element model of the hind limb was developed based on computerized tomographic imaging. The model successfully predicted the surface impedance values in the animals after crush injury and, by its inverse application, may be used to help determine the underlying electrical properties of muscle in various neuromuscular diseases based on surface impedance data.

  3. Biomedical engineering meets acupuncture - development of a miniaturized 48-channel skin impedance measurement system for needle and laser acupuncture

    Directory of Open Access Journals (Sweden)

    Wang Lu

    2010-11-01

    Full Text Available Abstract Background Due to controversially discussed results in scientific literature concerning changes of electrical skin impedance before and during acupuncture a new measurement system has been developed. Methods The prototype measures and analyzes the electrical skin impedance computer-based and simultaneously in 48 channels within a 2.5×3.5 cm matrix. Preliminary measurements in one person were performed using metal needle and violet laser (405 nm acupuncture at the acupoint Kongzui (LU6. The new system is an improvement on devices previously developed by other researchers for this purpose. Results Skin impedance in the immediate surroundings of the acupoint was lowered reproducibly following needle stimulation and also violet laser stimulation. Conclusions A new instrumentation for skin impedance measurements is presented. The following hypotheses suggested by our results will have to be tested in further studies: Needle acupuncture causes significant, specific local changes of electrical skin impedance parameters. Optical stimulation (violet laser at an acupoint causes direct electrical biosignal changes.

  4. Biomedical engineering meets acupuncture - development of a miniaturized 48-channel skin impedance measurement system for needle and laser acupuncture

    Science.gov (United States)

    2010-01-01

    Background Due to controversially discussed results in scientific literature concerning changes of electrical skin impedance before and during acupuncture a new measurement system has been developed. Methods The prototype measures and analyzes the electrical skin impedance computer-based and simultaneously in 48 channels within a 2.5×3.5 cm matrix. Preliminary measurements in one person were performed using metal needle and violet laser (405 nm) acupuncture at the acupoint Kongzui (LU6). The new system is an improvement on devices previously developed by other researchers for this purpose. Results Skin impedance in the immediate surroundings of the acupoint was lowered reproducibly following needle stimulation and also violet laser stimulation. Conclusions A new instrumentation for skin impedance measurements is presented. The following hypotheses suggested by our results will have to be tested in further studies: Needle acupuncture causes significant, specific local changes of electrical skin impedance parameters. Optical stimulation (violet laser) at an acupoint causes direct electrical biosignal changes. PMID:21092296

  5. A Cognitively Grounded Measure of Pronunciation Distance

    NARCIS (Netherlands)

    Wieling, M.; Nerbonne, J.; Bloem, J.; Gooskens, C.; Heeringa, W.; Baayen, R.H.

    2014-01-01

    In this study we develop pronunciation distances based on naive discriminative learning (NDL). Measures of pronunciation distance are used in several subfields of linguistics, including psycholinguistics, dialectology and typology. In contrast to the commonly used Levenshtein algorithm, NDL is groun

  6. Influence of the sample anticoagulant on the measurements of impedance aggregometry in cardiac surgery

    Directory of Open Access Journals (Sweden)

    Cristina Solomon

    2008-10-01

    postoperative day showed a significant recovery in platelet activity in the samples containing heparin (increase from 30 ± 22 U to 46 ± 27 U for the COLtest and from 70 ± 34 U to 95 ± 32 U for the TRAPtest, p < 0.001, Student’s t-test, while no significant recovery of platelet function could be established in the MEA measurements performed with citrated blood.Conclusions: The choice of blood sample anticoagulant used for impedance aggregometry influenced the platelet aggregation response. Postoperative platelet function recovery was only detected in the heparinized samples. Heparin seems to be better suited than citrate for the analysis of impedance aggregometry in heart surgery.Keywords: cardiac surgery, impedance aggregometry, platelet recovery, sample anticoagulant  

  7. Inhibition of neuronal cell-cell adhesion measured by the microscopic aggregation assay and impedance sensing

    Science.gov (United States)

    Wiertz, R. W. F.; Marani, E.; Rutten, W. L. C.

    2010-10-01

    Microscopic aggregation assay and impedance sensing (IS) were used to monitor a change in in vitro neuron-neuron adhesion in response to blocking of cell adhesion molecules. By blocking neuron-neuron adhesion, migration and aggregation of neuronal cells can be inhibited. This leads to better control of spatial arrangement of cells in culture. In the literature N-CAM, L1 and N-cadherin proteins are pointed out as main regulators of neuronal adhesion. In this study, these three main cell adhesion molecules were used to inhibit neuron-to-neuron adhesion and aggregation. Both soluble extracellular domains and antigen antibodies were added to these adhesion molecules. They were investigated for their blocking ability in neuronal cultures. First, in a 96 h aggregation assay on a low-adhesive substrate, the effect of inhibition of the three proteins on aggregation of cortical neurons was investigated optically. Both L1 antibody and L1 protein had no effect on the degree of aggregation. An N-cadherin antibody however was shown to be effective in aggregation inhibition at concentrations of 1 and 3 µg ml-1. Up to 96 h no aggregation occurred. A similar effect was achieved by the N-cadherin protein, although less distinct. N-CAM blocking revealed no inhibition of aggregation. Second, results from IS corresponded to those of the aggregation assays. In these experiments neuron-neuron adhesion was also inhibited by blocking N-CAM L1 and N-cadherin. Cortical neurons were cultured in small wells containing circular 100 µm diameter gold electrodes, so small changes in cell-cell interactions in monolayers of neurons could be monitored by IS. Impedances of neuron-covered electrodes were significantly lower in the presence of the N-cadherin antibody and protein at concentrations of 1, 3 and 10 µg ml-1, indicating a less profound binding between adjacent neurons. Results from the aggregation assays and impedance measurements demonstrate the applicability of blocking cell adhesion

  8. Analogies between the measurement of acoustic impedance via the reaction on the source method and the automatic microwave vector network analyzer technique

    Science.gov (United States)

    McLean, James; Sutton, Robert; Post, John

    2003-10-01

    One useful method of acoustic impedance measurement involves the measurement of the electrical impedance ``looking into'' the electrical port of a reciprocal electroacoustic transducer. This reaction on the source method greatly facilitates the measurement of acoustic impedance by borrowing highly refined techniques to measure electrical impedance. It is also well suited for in situ acoustic impedance measurements. In order to accurately determine acoustic impedance from the measured electrical impedance, the characteristics of the transducer must be accurately known, i.e., the characteristics of the transducer must be ``removed'' completely from the data. The measurement of acoustic impedance via the measurement of the reaction on the source is analogous to modern microwave measurements made with an automatic vector network analyzer. The action of the analyzer is described as de-embedding the desired data (such as acoustic impedance) from the raw data. Such measurements are fundamentally substitution measurements in that the transducer's characteristics are determined by measuring a set of reference standards. The reaction on the source method is extended to take advantage of improvements in microwave measurement techniques which allow calibration via imperfect standard loads. This removes one of the principal weaknesses of the method in that the requirement of high-quality reference standards is relaxed.

  9. A ship-borne meteorological station for ground truth measurements

    Digital Repository Service at National Institute of Oceanography (India)

    Desai, R.G.P.; Desa, B.A.E.

    Oceanographic upwelling studies required ground truth measurements of meteorological parameters and sea surface temperature to be made from a research vessel which did not have the necessary facilities. A ship-borne station was therefore designed...

  10. Correlation between percentage of body fat measured by the Slaughter equation and bio impedance analysis technique in Mexican schoolchildren

    Directory of Open Access Journals (Sweden)

    Mariana Orta Duarte

    2014-01-01

    Full Text Available Introduction: Obesity is considered one of the most serious public health problems of the 21st century in children and adolescents. The percentile or Z-score of the body mass index is widely used in children and adolescents to define and assess overweight and obesity, but it does not determine the percentage of total body fat. Other anthropometric measurements that determine total body fat are skinfold thickness and methods of body composition assessment such as bio impedance analysis, both of which are rapid and inexpensive. Objetive: The aim of the study was to correlate the percentage of body fat determined by the Slaughter equation with the percentage of body fat determined by the bio impedance analysis technique, and the body mass index in schoolchildren. Methods: The design of the study is cross-sectional and it was performed on a random selection of 74 children (9.47 ± 1.55 years old attending a primary school in Colima, Mexico during 2011. The percentage of body fat was measured by the Slaughter equation and bio impedance analysis technique. Body mass index was calculated. Inferential statistics were performed with the non-paired Student's t test, Pearson's correlation for quantitative variables (percentage of body fat by the Slaughter equation and bio impedance analysis and the Fisher exact test for qualitative variables. Results: A significant correlation (r = 0.74; p < 0.001 was identified between the percentage of fat measured by the Slaughter equation and bio impedance analysis. We also identified a significant correlation between the percentage of fat measured by the Slaughter equation and body mass index (r = 0. 85; p < 0.001 and the percentage of fat measured by bio impedance analysis and body mass index (r = 0.78; p < 0.001. Conclusion: Given that we identified a significant positive correlation between BIA and STE, we conclude that both are adequate alternatives for measuring the percentage of body fat among schoolchildren in

  11. Measuring two phase flow parameters using impedance cross-correlation flow meter

    Science.gov (United States)

    Muhamedsalih, Y.; Lucas, G.

    2012-03-01

    This paper describes the design and implementation of an impedance cross correlation flow meter which can be used in solids-water pipe flows to measure the local solids volume fraction distribution and the local solids velocity distribution. The system is composed of two arrays of electrodes, separated by an axial distance of 50 mm and each array contains eights electrodes mounted over the internal circumference of the pipe carrying the flow. Furthermore every electrode in each array can be selected to be either"excitation", "measurement" or "earth". Changing the electrode configuration leads to a change in the electric field, and hence in the region of the flow cross section which is interrogated. The local flow velocity in the interrogated region is obtained by cross correlation between the two electrode arrays. Additionally, the local solids volume fraction can be obtained from the mean mixture conductivity in the region under interrogation. The system is being integrated with a microcontroller to measure the velocity distribution of the solids and the volume fraction distribution of the solids in order to create a portable flow meter capable of measuring the multi-phase flow parameters without the need of a PC to control it. Integration of the product of the local solids volume fraction and the local solids velocity in the flow cross section enables the solids volumetric flow rate to be determined.

  12. Assessing risk of thyroid cancer using resonance-frequency based electrical impedance measurements

    Science.gov (United States)

    Zheng, Bin; Tublin, Mitchell E.; Lederman, Dror; Klym, Amy H.; Brown, Erica D.; Gur, David

    2011-03-01

    The incidence of thyroid cancer has risen faster than many malignancies and has nearly doubled in the USA over the past 30 years. Palpable nodules and subclinical nodules detected by imaging are found in a large percentage of the USA population. Most of these (.>95%) are fortunately benign. This vast reservoir of nodules makes the detection and diagnosis of thyroid cancer a diagnostic dilemma. Ultrasound guided Fine Needle Aspiration Biopsy (FNAB) is excellent for triaging patients but up to 25% of FNABs are inconclusive. As a result, definitive diagnosis is often only possible with a diagnostic lobectomy; many thousands of these are performed in the USA annually for ultimately benign disease. It would be extremely beneficial if we could develop a non-invasive procedure that could assist the diagnostician in reliably predicting the likelihood of malignancy of otherwise indeterminate thyroid nodules, thereby reducing the number of these "exploratory/diagnostic" lobectomies performed under general anesthesia. Electrical Impedance Spectroscopy (EIS) was considered as a possible approach to address this problem. However, the diagnostic accuracy of EIS is too low for routine clinical use to date. In our group, we developed a substantially modified technology termed Resonance-frequency Electrical Impedance Spectroscopy (REIS), which yields usable information for classifying risk of having breast abnormalities. We preliminarily applied REIS to measure signals on participants having thyroid nodules aiming to assess whether we can assist in improving diagnosis of indeterminate thyroid nodules. In this study we present a new multi-probe based REIS device specifically designed for the assessment of indeterminate thyroid nodules. Our preliminary assessment presented here demonstrates the feasibility of using this proposed REIS device in a busy tertiary care center.

  13. Ground and Airborne Methane Measurements with an Optical Parametric Amplifier

    Science.gov (United States)

    Numata, Kenji

    2012-01-01

    We report on ground and airborne atmospheric methane measurements with a differential absorption lidar using an optical parametric amplifier (OPA). Methane is a strong greenhouse gas on Earth and its accurate global mapping is urgently needed to understand climate change. We are developing a nanosecond-pulsed OPA for remote measurements of methane from an Earth-orbiting satellite. We have successfully demonstrated the detection of methane on the ground and from an airplane at approximately 11-km altitude.

  14. Minimum sample frequency for multichannel intraluminal impedance measurement of the oesophagus

    NARCIS (Netherlands)

    Bredenoord, AJ; Weusten, BLAM; Timmer, R; Smout, AJPM

    2004-01-01

    In all systems for impedance monitoring signals are stored in digital format after analog-to-digital conversion at a predefined rate, the sample frequency. We aimed to find the minimum sample frequency required to evaluate oesophageal transit and gastro-oesophageal reflux studies using impedance mon

  15. Measurement of instantaneous viscoelastic properties by impedance-frequency curve of the ventricle.

    Science.gov (United States)

    Koiwa, Y; Hashiguchi, R; Ohyama, T; Isoyama, S; Satoh, S; Suzuki, H; Takishima, T

    1986-04-01

    We developed a method for estimating the instantaneous viscoelastic properties of the left ventricle (LV). This impedance-curve method is based on the instantaneous impedance-frequency curve of the left ventricle generated by a rapidly oscillating mechanical impulse applied to the epicardial surface of the heart. The theoretical basis of the method and experimentally obtained instantaneous impedance-frequency curves were examined to evaluate the validity of our basic assumptions. Using these impedance-curve data, we calculated the instantaneous viscoelastic properties of the LV during the cardiac cycle. The impedance curve shows a configuration that is almost the same as the theoretical curve based on the assumption that an RCL (R, resistor; C, capacitor; L, inductor) parallel circuit is the electrical analog for the LV. The impedance curve varied moment by moment during the development of instantaneous LV pressure. The elastic and viscous coefficients, calculated from the impedance curve, increased with increase of LV pressure. We concluded that the impedance-curve method can delineate the instantaneous viscoelastic properties of the ventricle (especially of the ventricular myocardium).

  16. GIFTS EDU Ground-based Measurement Experiment

    Science.gov (United States)

    Zhou, Daniel K.; Smith, W. L., Sr.; Zollinger, L. J.; Huppi, R. J.; Reisse, R. A.; Larar, A. M.; Liu, X.; Tansock, J. J., Jr.; Jensen, S. M.; Revercomb, H. E.; Feltz, W. F.; Bingham, G. E.

    2007-01-01

    Geosynchronous Imaging Fourier Transform Spectrometer (GIFTS) Engineering Demonstration Unit (EDU) is an imaging infrared spectrometer designed for atmospheric soundings. The EDU groundbased measurement experiment was held in Logan, Utah during September 2006 to demonstrate its extensive capabilities for geosynchronous and other applications.

  17. Method to detect the end-point for PCR DNA amplification using an ionically labeled probe and measuring impedance change

    Science.gov (United States)

    Miles, Robin R.; Belgrader, Phillip; Fuller, Christopher D.

    2007-01-02

    Impedance measurements are used to detect the end-point for PCR DNA amplification. A pair of spaced electrodes are located on a surface of a microfluidic channel and an AC or DC voltage is applied across the electrodes to produce an electric field. An ionically labeled probe will attach to a complementary DNA segment, and a polymerase enzyme will release the ionic label. This causes the conductivity of the solution in the area of the electrode to change. This change in conductivity is measured as a change in the impedance been the two electrodes.

  18. Impedance measurements of self-assembled lipid bilayer membranes on the tip of an electrode.

    Science.gov (United States)

    Bordi, F; Cametti, Cesare; Gliozzi, A

    2002-07-01

    Supported lipid membranes were self-assembled on the tip of a freshly cleaved silver wire, in the presence of an appropriate polarization voltage, to facilitate, during the membrane formation, the organization of the lipids into an ordered structure. Radiowave impedance spectroscopy measurements have been carried out to provide information on the relaxation properties of the system. We have measured the conductometric and dielectric properties of bilayers built up of different lipids [dipalmitoylphosphatidic acid (DPPA), 1,2-dipalmitoyl-sn-glycero-3-phosphocholine (DPPC), linoleic acid (LIN)] in a wide frequency range (from 10(3) to 10(6) Hz) and in electrolyte solutions of different ionic strengths, in the presence of uni-univalent (KCl) and di-univalent (CaCl(2), MgCl(2), ZnCl(2)) electrolytes. This made it possible to measure the influence of different cations and different lipid compositions on the membrane properties. In particular, we have found a different capacitive behaviour of the supported lipid bilayer membrane (s-BLM) structure in the presence of different counterions in the electrolyte solution. This peculiarity offers the opportunity for the preparation of a variety of biosensors with diverse applications in membrane biophysics, biochemistry and biotechnology.

  19. Transcutaneous Intraluminal Impedance Measurement for Minimally Invasive Monitoring of Gastric Motility: Validation in Acute Canine Models

    Directory of Open Access Journals (Sweden)

    Michael D. Poscente

    2014-01-01

    Full Text Available Transcutaneous intraluminal impedance measurement (TIIM is a new method to cutaneously measure gastric contractions by assessing the attenuation dynamics of a small oscillating voltage emitted by a battery-powered ingestible capsule retained in the stomach. In the present study, we investigated whether TIIM can reliably assess gastric motility in acute canine models. Methods. Eight mongrel dogs were randomly divided into 2 groups: half received an active TIIM pill and half received an identically sized sham capsule. After 24-hour fasting and transoral administration of the pill (active or sham, two force transducers (FT were sutured onto the antral serosa at laparotomy. After closure, three standard cutaneous electrodes were placed on the abdomen, registering the transluminally emitted voltage. Thirty-minute baseline recordings were followed by pharmacological induction of gastric contractions using neostigmine IV and another 30-minute recording. Normalized one-minute baseline and post-neostigmine gastric motility indices (GMIs were calculated and Pearson correlation coefficients (PCCs between cutaneous and FT GMIs were obtained. Statistically significant GMI PCCs were seen in both baseline and post-neostigmine states. There were no significant GMI PCCs in the sham capsule test. Further chronic animal studies of this novel long-term gastric motility measurement technique are needed before testing it on humans.

  20. A Cuffless Blood Pressure Measurement Based on the Impedance Plethysmography Technique

    Directory of Open Access Journals (Sweden)

    Shing-Hong Liu

    2017-05-01

    Full Text Available In the last decade, cuffless blood pressure measurement technology has been widely studied because it could be applied to a wearable apparatus. Electrocardiography (ECG, photo-plethysmography (PPG, and phonocardiography are always used to detect the pulse transit time (PTT because the changed tendencies of the PTT and blood pressure have a negative relationship. In this study, the PPG signal was replaced by the impedance plethysmography (IPG signal and was used to detect the PTT. The placement and direction of the electrode array for the IPG measurement were discussed. Then, we designed an IPG ring that could measure an accurate IPG signal. Twenty healthy subjects participated in this study. The changes in blood pressure after exercise were evaluated through the changes of the PTT. The results showed that the change of the systolic pressure had a better relationship with the change of the PTTIPG than that of the PTTPPG (r = 0.700 vs. r = 0.450. Moreover, the IPG ring with spot electrodes would be more suitable to develop with the wearable cuffless blood pressure monitor than the PPG sensor.

  1. Measurement of fluid viscosity at microliter volumes using quartz impedance analysis.

    Science.gov (United States)

    Saluja, Atul; Kalonia, Devendra S

    2004-08-05

    The purpose of this work was to measure viscosity of fluids at low microliter volumes by means of quartz crystal impedance analysis. To achieve this, a novel setup was designed that allowed for measurement of viscosity at volumes of 8 to 10 microL. The technique was based on the principle of electromechanical coupling of piezoelectric quartz crystals. The arrangement was simple with measurement times ranging from 2 to 3 minutes. The crystal setup assembly did not impose any unwanted initial stress on the unloaded quartz crystal. Quartz crystals of 5- and 10-MHz fundamental frequency were calibrated with glycerol-water mixtures of known density and viscosity prior to viscosity measurements. True frequency shifts, for the purpose of this work, were determined followed by viscosity measurement of aqueous solutions of sucrose, urea, PEG-400, glucose, and ethylene glycol at 25 degrees C +/- 0.5 degrees C. The measured viscosities were found to be reproducible and consistent with the values reported in the literature. Minor inconsistencies in the measured resistance and frequency shifts did not affect the results significantly, and were found to be experimental in origin rather than due to electrode surface roughness. Besides, as expected for a viscoelastic fluid, PEG 8000 solutions, the calculated viscosities were found to be less than the reported values due to frequency dependence of storage and loss modulus components of complex viscosity. From the results, it can be concluded that the present setup can provide accurate assessment of viscosity of Newtonian fluids and also shows potential for analyzing non-Newtonian fluids at low microliter volumes.

  2. Orientation effect on ground motion measurement for Mexican subduction earthquakes

    Institute of Scientific and Technical Information of China (English)

    H.P Hong; A. Pozos-Estrada; R. Gomez

    2009-01-01

    The existence of the principal directions of the ground motion based on Arias intensity is well-known. These principal directions do not necessarily coincide with the orientations of recording sensors or with the orientations along which the ground motion parameters such as the peak ground acceleration and the pseudo-spectral acceleration (PSA) are maximum. This is evidenced by the fact that the maximum PSA at different natural vibration periods for horizontal excitations do not correspond to the same orientation. A recent analysis carried out for California earthquake records suggests that an orientation-dependent ground motion measurement for horizontal excitations can be developed. The main objective of this study is to investigate and provide seismic ground motion measurements in the horizontal plane, including bidirectional horizontal ground motions, for Mexican interplate and inslab earthquake records. Extensive statistical analyses of PSA are conducted for the assessment, The analysis results suggest that similar to the case of California records, the average behavior of the ratio of the PSA to the maximum resulting PSA can be approximated by a quarter of an ellipse in one quadrant; and that the ratio can be considered to be independent of the value of the maximum resulting PSA, earthquake magnitude, earthquake distance and the focal depth. Sets of response ratios and attenuation relationships that can be used to represent a bidirectional horizontal ground motion measurement for Mexican interplate and inslab earthquakes were also developed.

  3. Ground-Based Aerosol Measurements | Science Inventory ...

    Science.gov (United States)

    Atmospheric particulate matter (PM) is a complex chemical mixture of liquid and solid particles suspended in air (Seinfeld and Pandis 2016). Measurements of this complex mixture form the basis of our knowledge regarding particle formation, source-receptor relationships, data to test and verify complex air quality models, and how PM impacts human health, visibility, global warming, and ecological systems (EPA 2009). Historically, PM samples have been collected on filters or other substrates with subsequent chemical analysis in the laboratory and this is still the major approach for routine networks (Chow 2005; Solomon et al. 2014) as well as in research studies. In this approach, air, at a specified flow rate and time period, is typically drawn through an inlet, usually a size selective inlet, and then drawn through filters, 1 INTRODUCTION Atmospheric particulate matter (PM) is a complex chemical mixture of liquid and solid particles suspended in air (Seinfeld and Pandis 2016). Measurements of this complex mixture form the basis of our knowledge regarding particle formation, source-receptor relationships, data to test and verify complex air quality models, and how PM impacts human health, visibility, global warming, and ecological systems (EPA 2009). Historically, PM samples have been collected on filters or other substrates with subsequent chemical analysis in the laboratory and this is still the major approach for routine networks (Chow 2005; Solomo

  4. A Multiphase Flow Measurement System Comprising an Impedance Cross Correlation (ICC) Device and an Imaging Electromagnetic Flow Meter (IEF).

    OpenAIRE

    Meng, Yiqing; Lucas, Gary

    2012-01-01

    Flow measurements are playing increasingly important roles in many different application areas, such as manufacturing processes and the oil & gas industry. Multiphase flow measurement in particular is becoming increasingly important to the oil industry. This project concerns the design and implementation of a two-phase flow measurement system which integrates an impedance cross correlation (ICC) flow meter - which can be utilized for measuring the local dispersed phase volume fraction distrib...

  5. Two-Point Stretchable Electrode Array for Endoluminal Electrochemical Impedance Spectroscopy Measurements of Lipid-Laden Atherosclerotic Plaques.

    Science.gov (United States)

    Packard, René R Sevag; Zhang, XiaoXiao; Luo, Yuan; Ma, Teng; Jen, Nelson; Ma, Jianguo; Demer, Linda L; Zhou, Qifa; Sayre, James W; Li, Rongsong; Tai, Yu-Chong; Hsiai, Tzung K

    2016-09-01

    Four-point electrode systems are commonly used for electric impedance measurements of biomaterials and tissues. We introduce a 2-point system to reduce electrode polarization for heterogeneous measurements of vascular wall. Presence of endoluminal oxidized low density lipoprotein (oxLDL) and lipids alters the electrochemical impedance that can be measured by electrochemical impedance spectroscopy (EIS). We developed a catheter-based 2-point micro-electrode configuration for intravascular deployment in New Zealand White rabbits. An array of 2 flexible round electrodes, 240 µm in diameter and separated by 400 µm was microfabricated and mounted on an inflatable balloon catheter for EIS measurement of the oxLDL-rich lesions developed as a result of high-fat diet-induced hyperlipidemia. Upon balloon inflation, the 2-point electrode array conformed to the arterial wall to allow deep intraplaque penetration via alternating current (AC). The frequency sweep from 10 to 300 kHz generated an increase in capacitance, providing distinct changes in both impedance (Ω) and phase (ϕ) in relation to varying degrees of intraplaque lipid burden in the aorta. Aortic endoluminal EIS measurements were compared with epicardial fat tissue and validated by intravascular ultrasound and immunohistochemistry for plaque lipids and foam cells. Thus, we demonstrate a new approach to quantify endoluminal EIS via a 2-point stretchable electrode strategy.

  6. Effect of Electrode Belt and Body Positions on Regional Pulmonary Ventilation- and Perfusion-Related Impedance Changes Measured by Electric Impedance Tomography

    Science.gov (United States)

    Ericsson, Elin; Tesselaar, Erik; Sjöberg, Folke

    2016-01-01

    Ventilator-induced or ventilator-associated lung injury (VILI/VALI) is common and there is an increasing demand for a tool that can optimize ventilator settings. Electrical impedance tomography (EIT) can detect changes in impedance caused by pulmonary ventilation and perfusion, but the effect of changes in the position of the body and in the placing of the electrode belt on the impedance signal have not to our knowledge been thoroughly evaluated. We therefore studied ventilation-related and perfusion-related changes in impedance during spontaneous breathing in 10 healthy subjects in five different body positions and with the electrode belt placed at three different thoracic positions using a 32-electrode EIT system. We found differences between regions of interest that could be attributed to changes in the position of the body, and differences in impedance amplitudes when the position of the electrode belt was changed. Ventilation-related changes in impedance could therefore be related to changes in the position of both the body and the electrode belt. Perfusion-related changes in impedance were probably related to the interference of major vessels. While these findings give us some insight into the sources of variation in impedance signals as a result of changes in the positions of both the body and the electrode belt, further studies on the origin of the perfusion-related impedance signal are needed to improve EIT further as a tool for the monitoring of pulmonary ventilation and perfusion. PMID:27253433

  7. Effect of Electrode Belt and Body Positions on Regional Pulmonary Ventilation- and Perfusion-Related Impedance Changes Measured by Electric Impedance Tomography.

    Directory of Open Access Journals (Sweden)

    Elin Ericsson

    Full Text Available Ventilator-induced or ventilator-associated lung injury (VILI/VALI is common and there is an increasing demand for a tool that can optimize ventilator settings. Electrical impedance tomography (EIT can detect changes in impedance caused by pulmonary ventilation and perfusion, but the effect of changes in the position of the body and in the placing of the electrode belt on the impedance signal have not to our knowledge been thoroughly evaluated. We therefore studied ventilation-related and perfusion-related changes in impedance during spontaneous breathing in 10 healthy subjects in five different body positions and with the electrode belt placed at three different thoracic positions using a 32-electrode EIT system. We found differences between regions of interest that could be attributed to changes in the position of the body, and differences in impedance amplitudes when the position of the electrode belt was changed. Ventilation-related changes in impedance could therefore be related to changes in the position of both the body and the electrode belt. Perfusion-related changes in impedance were probably related to the interference of major vessels. While these findings give us some insight into the sources of variation in impedance signals as a result of changes in the positions of both the body and the electrode belt, further studies on the origin of the perfusion-related impedance signal are needed to improve EIT further as a tool for the monitoring of pulmonary ventilation and perfusion.

  8. CERN LINAC4 H- Source and SPL plasma generator RF systems, RF power coupling and impedance measurements

    CERN Document Server

    Paoluzzi, M; Marques-Balula, J; Nisbet, D

    2010-01-01

    In the LINAC4 H- source and the SPL plasma generator at CERN, the plasma is heated by a 100 kW, 2 MHz RF system. Matching of the load impedance to the final amplifier is achieved with a resonant network. The system implements a servo loop for power stabilization and frequency hopping to cope with the detuning effects induced by the plasma. This paper provides a detailed description of the system, including the pulse rate increase to 50 Hz for use in the SPL plasma generator. The performances, measurements of RF power coupling, contribution of the plasma to the impedance as well as first operation are reported.

  9. Evaluation of impedance measurements on mild steel corrosion in acid media in the presence of heterocyclic compounds

    Energy Technology Data Exchange (ETDEWEB)

    Popova, A. [Department of Physical Chemistry, University of Chemical Technology and Metallurgy, 8 Kl. Ohridski Street, 1756 Sofia (Bulgaria)]. E-mail: chr@uctm.edu; Christov, M. [Department of Physical Chemistry, University of Chemical Technology and Metallurgy, 8 Kl. Ohridski Street, 1756 Sofia (Bulgaria)

    2006-10-15

    Five heterocyclic compounds, having a five atom ring, fused with the benzene ring (indole, benzimidazole, benzotriazole, benzothiazole and benzothiadiazole) were investigated as corrosion inhibitors of mild steel in 1 N HCl using impedance and polarisation resistance methods. Four of these compounds exhibit inhibition properties, while one of them, benzothiadiazole, stimulates the corrosion process. Adequate structure models of the interface are offered. The experimental data show a frequency distribution and therefore a modelling element with frequency dispersion behaviour, a constant phase element (CPE) has been used. At high inhibitor concentrations a second time constant is observed in the impedance spectra. The values of the polarisation resistance determined by the polarisation resistance method are well correlated with the sum of the separate resistances from the impedance measurements.

  10. A wideband high common mode rejection ratio amplifier and phase-locked loop demodulator for multifrequency impedance measurement.

    Science.gov (United States)

    Goovaerts, H G; Faes, T J; Raaijmakers, E; Heethaar, R M

    1998-11-01

    Design considerations and implementation of a multifrequency measuring channel for application in the field of bio-impedance measurement are discussed in this paper. The input amplifier has a differential configuration which is electrically isolated from the remaining circuits. Transformer coupling provides improved common mode rejection when compared to non-isolated input stages. The frequency characteristic of the section between input and demodulator is flat within +/- 0.1 dB between 4 kHz and 1024 kHz. The synchronous demodulator is based on a wideband switched video amplifier. In contrast to commonly used lock--in techniques, the carrier for demodulation is recovered from the input signal by means of a phase-locked loop. This method ensures zero phase shift with respect to the input signal and improves the accuracy of measurement. The system has been developed primarily for thoracic impedance cardiography (TIC) but has also successfully been applied in the field of total body bio-impedance analysis (BIA). At present an electrical impedance tomograph is under development based on the instrumentation described. Results regarding the measurement range and accuracy are given and some recordings of patient data are shown.

  11. Electromagnetic model of a near-field cable-free impedance and gain measurement technique for electrically small antennas

    DEFF Research Database (Denmark)

    Zhang, Jiaying; Pivnenko, Sergey; Breinbjerg, Olav

    2011-01-01

    the signal scattered by it when it is loaded in turn with three known loads. The determination of the antenna impedance and gain is formulated by using the spherical wave expansion technique. The advantages of this measurement technique are summarized as follows. First, the limited dynamic range problem...

  12. Local transverse coupling impedance measurements in a synchrotron light source from turn-by-turn acquisitions

    National Research Council Canada - National Science Library

    Carlà, Michele; Benedetti, Gabriele; Günzel, Thomas; Iriso, Ubaldo; Martí, Zeus

    2016-01-01

    .... Beam position monitor turn-by-turn analysis for impedance characterization has been usually employed in large circumference machines, while synchrotron light sources have mainly used slow orbit based techniques...

  13. Preliminary results of ground reflectivity measurements using noise radar

    Science.gov (United States)

    Maślikowski, Łukasz; Krysik, Piotr; Dąbrowska-Zielińska, Katarzyna; Kowalik, Wanda; Bartold, Maciej

    2011-10-01

    The paper describes experimental L-band ground reflectivity measurement using noise radar demonstrator working as a scatterometer. The radar ground return is usually described with a scattering coefficient, a quantity that is independent from the scatterometer system. To calculate the coefficient in a function of incidence angle, range profile values obtained after range compression were used. In order to improve dynamic range of the measurement, antenna cross-path interference was removed using lattice filter. The ground return was measured at L band both for HH and VV polarizations of radar wave as well as for HV and VH crosspolarizations using log-periodic antennas placed at a 10 m high mast directed towards a meadow surface. In the paper the theoretical considerations, noise radar setup, measurement campaign and the results are described.

  14. Cold vacuum chamber for diagnostics: Analysis of the measurements at the Diamond Light Source and impedance bench measurements

    Science.gov (United States)

    Voutta, R.; Gerstl, S.; Casalbuoni, S.; Grau, A. W.; Holubek, T.; Saez de Jauregui, D.; Bartolini, R.; Cox, M. P.; Longhi, E. C.; Rehm, G.; Schouten, J. C.; Walker, R. P.; Migliorati, M.; Spataro, B.

    2016-05-01

    The beam heat load is an important input parameter needed for the cryogenic design of superconducting insertion devices. Theoretical models taking into account the different heating mechanisms of an electron beam to a cold bore predict smaller values than the ones measured with several superconducting insertion devices installed in different electron storage rings. In order to measure and possibly understand the beam heat load to a cold bore, a cold vacuum chamber for diagnostics (COLDDIAG) has been built. COLDDIAG is equipped with temperature sensors, pressure gauges, mass spectrometers as well as retarding field analyzers which allow to measure the beam heat load, total pressure, and gas content as well as the flux of particles hitting the chamber walls. COLDDIAG was installed in a straight section of the Diamond Light Source (DLS). In a previous paper the experimental equipment as well as the installation of COLDDIAG in the DLS are described [S. Gerstl et al., Phys. Rev. ST Accel. Beams 17, 103201 (2014)]. In this paper we present an overview of all the measurements performed with COLDDIAG at the DLS and their detailed analysis, as well as impedance bench measurements of the cold beam vacuum chamber performed at the Karlsruhe Institute of Technology after removal from the DLS. Relevant conclusions for the cryogenic design of superconducting insertion devices are drawn from the obtained results.

  15. The Initial Systolic Time Interval in patients with spinal cord injury measured with impedance cardiography

    Science.gov (United States)

    Hoekstra, Femke; Martinsen, Ørjan G.; Verdaasdonk, Rudolf M.; Janssen, Thomas W. J.; Meijer, Jan H.

    2012-12-01

    The Initial Systolic Time Interval (ISTI), obtained from the electrocardiogram and impedance cardiogram, is considered to be a measure for the time delay between the electrical and mechanical activity of the heart. This time delay is influenced by the sympathetic nerve system. Therefore, an observational study was performed in a group of patients (SCI) with spinal cord injuries. The relationship between the ISTI and the total heart cycle (RR-interval) was established by varying the RR-interval using an exercise stimulus to increase the heart rate. The slope of this relationship was observed to be significantly higher in the SCI-group as compared with a control group, although there was no difference in ISTI in the range of common heart rates during the test between the groups. This slope and the ISTI was observed to be significantly different in an acute patient having a recent spinal cord injury at a high level. Because of the variety in injury levels and incompleteness of the injuries further, more specific research is necessary to draw decisive conclusions with respect to the contribution of autonomic nervous control on the ISTI in SCI, although the present observations are notable.

  16. Electrochemical impedance spectroscopic measurements of FCCP-induced change in membrane permeability of MDCK cells.

    Science.gov (United States)

    Zhao, Lingzhi; Li, Xianchan; Lin, Yuqing; Yang, Lifen; Yu, Ping; Mao, Lanqun

    2012-05-07

    This study demonstrates a new electrochemical impedance spectroscopic (EIS) method for measurements of the changes in membrane permeability during the process of cell anoxia. Madin-Darby canine kidney (MDCK) cells were employed as the model cells and were cultured onto gelatin-modified glassy carbon (GC) electrodes. EIS measurements were conducted at the MDCK/gelatin-modified GC electrodes with Fe(CN)(6)(3-/4-) as the redox probe. The anoxia of the cells grown onto electrode surface was induced by the addition of carbonycyanide p-(trifluoromethoxy) phenylhydrazone (FCCP) into the cell culture, in which the MDCK/gelatin-modified GC electrodes were immersed for different times. The EIS results show that the presence of FCCP in the cell culture clearly decreases the charge-transfer resistance of the Fe(CN)(6)(3-/4-) redox probe at the MDCK/gelatin-modified GC electrodes, and the charge-transfer resistance decreases with increasing time employed for immersing the MDCK/gelatin-modified GC electrodes into the cell culture containing FCCP. These results demonstrate that the EIS method could be used to monitor the changes in the cell membrane permeability during the FCCP-induced cell anoxia. To simulate the EIS system, a rational equivalent circuit was proposed and the values of ohmic resistance of the electrolyte, charge-transfer resistance and constant phase elements for both the gelatin and the cell layers are given with the fitting error in an acceptable value. This study actually offers a new and simple approach to measuring the dynamic process of cell death induced by anoxia through monitoring the changes in the cell membrane permeability.

  17. Planar Near-Field Measurements of Ground Penetrating Radar Antennas

    DEFF Research Database (Denmark)

    Meincke, Peter; Hansen, Thorkild

    2004-01-01

    Planar near-field measurements are formulated for a general ground penetrating radar (GPR) antenna. A total plane-wave scattering matrix is defined for the system consisting of the GPR antenna and the planar air-soil interface. The transmitting spectrum of the GPR antenna is expressed in terms...... of measurements obtained with a buried probe as the GPR antenna moves over a scan plane on the ground. A numerical example in which the scan plane is finite validates the expressions for the spectrum of the GPR antenna....

  18. Ground-Based Lidar for Atmospheric Boundary Layer Ozone Measurements

    Science.gov (United States)

    Kuang, Shi; Newchurch, Michael J.; Burris, John; Liu, Xiong

    2013-01-01

    Ground-based lidars are suitable for long-term ozone monitoring as a complement to satellite and ozonesonde measurements. However, current ground-based lidars are unable to consistently measure ozone below 500 m above ground level (AGL) due to both engineering issues and high retrieval sensitivity to various measurement errors. In this paper, we present our instrument design, retrieval techniques, and preliminary results that focus on the high-temporal profiling of ozone within the atmospheric boundary layer (ABL) achieved by the addition of an inexpensive and compact mini-receiver to the previous system. For the first time, to the best of our knowledge, the lowest, consistently achievable observation height has been extended down to 125 m AGL for a ground-based ozone lidar system. Both the analysis and preliminary measurements demonstrate that this lidar measures ozone with a precision generally better than 10% at a temporal resolution of 10 min and a vertical resolution from 150 m at the bottom of the ABL to 550 m at the top. A measurement example from summertime shows that inhomogeneous ozone aloft was affected by both surface emissions and the evolution of ABL structures.

  19. Ground-based lidar for atmospheric boundary layer ozone measurements.

    Science.gov (United States)

    Kuang, Shi; Newchurch, Michael J; Burris, John; Liu, Xiong

    2013-05-20

    Ground-based lidars are suitable for long-term ozone monitoring as a complement to satellite and ozonesonde measurements. However, current ground-based lidars are unable to consistently measure ozone below 500 m above ground level (AGL) due to both engineering issues and high retrieval sensitivity to various measurement errors. In this paper, we present our instrument design, retrieval techniques, and preliminary results that focus on the high-temporal profiling of ozone within the atmospheric boundary layer (ABL) achieved by the addition of an inexpensive and compact mini-receiver to the previous system. For the first time, to the best of our knowledge, the lowest, consistently achievable observation height has been extended down to 125 m AGL for a ground-based ozone lidar system. Both the analysis and preliminary measurements demonstrate that this lidar measures ozone with a precision generally better than ±10% at a temporal resolution of 10 min and a vertical resolution from 150 m at the bottom of the ABL to 550 m at the top. A measurement example from summertime shows that inhomogeneous ozone aloft was affected by both surface emissions and the evolution of ABL structures.

  20. Load monitoring of pin-connected structures using piezoelectric impedance measurement

    Science.gov (United States)

    Liang, Yabin; Li, Dongsheng; Parvasi, Seyed Mohammad; Song, Gangbing

    2016-10-01

    This paper presents a feasibility study on a developed impedance-based technique using Lead Zirconate Titanate patches for load monitoring of pin-connected structures, which are widely used in construction industry. The basic principle behind the load-monitoring technique is to utilize a high-frequency excitation signal (typically >30 kHz) through a surface-bonded piezoelectric sensor/actuator to detect changes in mechanical impedance of the structure due to the variations in structural loads. In order to verify the effectiveness of the developed technique, a tension-controllable structure with a pin connection was fabricated and investigated in this study. A load monitoring index was used to correlate the dominating peak frequency of the real part of the electrical impedance signature to the pin connection load. Experimental results obtained from twenty repeated tests prove that the proposed load-monitoring index increases as the load on the pin connection increases due to the enlarging true contact area of the pin connection. A 3D finite element method was also used to simulate and analyze the impedance signature of a pin connection model. Very good agreement exists between the numerical simulation’s results and the experimental results which demonstrates that the impedance-based technique can successfully be used to monitor the loading status of pin connections in practical applications.

  1. Practical aspects of tritium measurement in ground and surface waters

    Energy Technology Data Exchange (ETDEWEB)

    Nitzsche, O. [Technische Univ. Bergakademie Freiberg (Germany). Inst. fuer Angewandte Physik; Hebert, D. [Technische Univ. Bergakademie Freiberg (Germany). Inst. fuer Angewandte Physik

    1997-03-01

    Tritium measurements are a powerful tool in hydrological and hydrogeological investigations for detecting mean residence times of several water reservoirs. Due to the low tritium activities in precipitation, ground and surface waters a low level measurement is necessary. Therefore often the liquid scintillation counting after an electrolytic enrichment of water is used. In this paper some practical aspects and problems of measurement are discussed and the problem of contamination in low level laboratories is shown. (orig.)

  2. Numerical simulation of particle dynamics in an orifice-electrode system. Application to counting and sizing by impedance measurement.

    Science.gov (United States)

    Isèbe, Damien; Nérin, Philippe

    2013-04-01

    This paper describes how to numerically tackle the problem of counting and sizing particles by impedance measurement in an orifice-electrode system. The model allows to simulate the particle dynamics submitted to strong hydrodynamic stresses through a microorifice and to compute the voltage pulses generated by the modification of the inner dielectric medium. This approach gives important information about particles size distribution and allows to quantify the role of trajectory and orientation of particles on the size measurement.

  3. Method, system and computer-readable media for measuring impedance of an energy storage device

    Energy Technology Data Exchange (ETDEWEB)

    Morrison, John L.; Morrison, William H.; Christophersen, Jon P.; Motloch, Chester G.

    2016-01-26

    Real-time battery impedance spectrum is acquired using a one-time record. Fast Summation Transformation (FST) is a parallel method of acquiring a real-time battery impedance spectrum using a one-time record that enables battery diagnostics. An excitation current to a battery is a sum of equal amplitude sine waves of frequencies that are octave harmonics spread over a range of interest. A sample frequency is also octave and harmonically related to all frequencies in the sum. A time profile of this sampled signal has a duration that is a few periods of the lowest frequency. A voltage response of the battery, average deleted, is an impedance of the battery in a time domain. Since the excitation frequencies are known and octave and harmonically related, a simple algorithm, FST, processes the time profile by rectifying relative to sine and cosine of each frequency. Another algorithm yields real and imaginary components for each frequency.

  4. Beam Measurements of the Longitudinal impedance of the CERN Super Proton Synchrotron

    CERN Document Server

    AUTHOR|(CDS)2090034; Petrache, Costel

    One of the main challenges of future physics projects based on particle accelerators is the need for high intensity beams. However, collective effects are a major limitation which can deteriorate the beam quality or limit the maximum intensity due to losses. The CERN SPS, which is the last injector for the LHC, is currently unable to deliver the beams required for future projects due to longitudinal instabilities. The numerous devices in the machine (accelerating RF cavities, injection and extraction magnets, vacuum flanges. etc.) lead to variations in the geometry and material of the chamber through which the beam is travelling. The electromagnetic interaction within the beam (space charge) and of the beam with its environment are described by a coupling impedance which affects the motion of the particles and leads to instabilities for high beam intensities. Consequently, the critical impedance sources should be identified and solutions assessed. To have a reliable impedance model of an accelerator, the...

  5. Epiphyte-cover on seagrass (Zostera marina L. leaves impedes plant performance and radial O2 loss from the below-ground tissue

    Directory of Open Access Journals (Sweden)

    Kasper Elgetti Brodersen

    2015-08-01

    Full Text Available The O2 budget of seagrasses is a complex interaction between several sources and sinks, which is strongly regulated by light availability and mass transfer over the diffusive boundary layer (DBL surrounding the plant. Epiphyte growth on leaves may thus strongly affect the O2 availability of the seagrass plant and its capability to aerate its rhizosphere as a defence against plant toxins.We used electrochemical and fiber-optic microsensors to quantify the O2 flux, DBL and light microclimate around leaves with and without filamentous algal epiphytes. We also quantified the below-ground radial O2 loss from roots (~1 mm from the root-apex to elucidate how this below-ground oxic microzone was affected by the presence of epiphytes.Epiphyte-cover on seagrass leaves (~21% areal cover resulted in reduced light quality and quantity for photosynthesis, thus leading to reduced plant fitness. A ~4 times thicker diffusive boundary layer around leaves with epiphyte-cover impeded gas (and nutrient exchange with the surrounding water-column and thus the amount of O2 passively diffusing into the leaves in darkness. During light exposure of the leaves, radial oxygen loss from the below-ground tissue was ~2 times higher from plants without epiphyte-cover. In contrast, no O2 was detectable at the surface of the root-cap tissue of plants with epiphyte-cover during darkness, leaving the plants more susceptible to sulphide intrusion.Epiphyte growth on seagrass leaves thus negatively affects the light climate and O2 uptake in darkness, hampering the plants performance and thereby reducing the oxidation capability of its below-ground tissue.

  6. Comparison between Laboratory Measurements, Simulations and Analytical Predictions of the Resistive Wall Transverse Beam Impedance at low frequencies

    CERN Document Server

    Roncarolo, F; Kroyer, T; Métral, E; Salvant, B

    2008-01-01

    The prediction of the resistive wall transverse beam impedance at the first unstable betatron line (8 kHz) of the CERN Large Hadron Collider (LHC) is of paramount importance for understanding and controlling the related coupled-bunch instability. Until now only novel analytical formulas were available at this frequency. Recently, laboratory measurements and numerical simulations were performed to crosscheck the analytical predictions. The experimental results based on the measurement of the variation of a probe coil inductance in the presence of i) sample graphite plates, ii) stand-alone LHC collimator jaws and iii) a full LHC collimator assembly are presented in detail. The measurement results are compared to both analytical theories and simulations. In addition, the consequences for the understanding of the LHC impedance are discussed.

  7. Imaging electrical impedance from acoustic measurements by means of magnetoacoustic tomography with magnetic induction (MAT-MI).

    Science.gov (United States)

    Li, Xu; Xu, Yuan; He, Bin

    2007-02-01

    We have conducted computer simulation and experimental studies on magnetoacoustic-tomography with magnetic induction (MAT-MI) for electrical impedance imaging. In MAT-MI, the object to be imaged is placed in a static magnetic field, while pulsed magnetic stimulation is applied in order to induce eddy current in the object. In the static magnetic field, the Lorentz force acts upon the eddy current and causes acoustic vibrations in the object. The propagated acoustic wave is then measured around the object to reconstruct the electrical impedance distribution. In the present simulation study, a two-layer spherical model is used. Parameters of the model such as sample size, conductivity values, strength of the static and pulsed magnetic field, are set to simulate features of biological tissue samples and feasible experimental constraints. In the forward simulation, the electrical potential and current density are solved using Poisson's equation, and the acoustic pressure is calculated as the forward solution. The electrical impedance distribution is then reconstructed from the simulated pressure distribution surrounding the sample. The present computer simulation results suggest that MAT-MI can reconstruct conductivity images of biological tissue with high spatial resolution and high contrast. The feasibility of MAT-MI in providing high spatial resolution images containing impedance-related information has also been demonstrated in a phantom experiment.

  8. Effectiveness of thigh-to-thigh current path for the measurement of abdominal fat in bioelectrical impedance analysis.

    Science.gov (United States)

    Hong, Ki Hwan; Lim, Yong Gyu; Park, Kwang Suk

    2009-12-01

    We present a new method measuring body impedance using a thigh-to-thigh current path, which can reflect the abdominal fat portion more sensitively and can be conveniently applied during the daily use on a toilet seat. Two pairs of electrodes were installed on a toilet seat to provide current and to permit voltage measurement through a thigh-to-thigh current path. The effectiveness of the method was compared with conventional foot-to-foot and hand-to-foot current paths by simulation and by experiments referenced to computed tomography (CT) image analysis. Body impedance using three different current paths was measured, and abdominal CT images were acquired for eight subjects. Measured body impedances were compared with the visceral to subcutaneous fat ratio (VF/SF) calculated from the CT-determined abdominal fat volume. The thigh-to-thigh current path was about 75% more sensitive in abdominal fat measurement than the conventional current paths in simulation experiments and displayed a higher VF/SF correlation (r = 0.768) than the foot-to-foot (r = 0.425) and hand-to-foot (r = 0.497) current paths.

  9. SUPERFUND GROUND WATER ISSUE - ACCURACY OF DEPTH TO WATER MEASUREMENTS

    Science.gov (United States)

    Accuracy of depth to water measurements is an issue identified by the Forum as a concern of Superfund decision-makers as they attempt to determine directions of ground-water flow, areas of recharge of discharge, the hydraulic characteristics of aquifers, or the effects of manmade...

  10. Planar Near-Field Measurements of Ground Penetrating Radar Antennas

    DEFF Research Database (Denmark)

    Meincke, Peter; Hansen, Thorkild

    2004-01-01

    Planar near-field measurements are formulated for a general ground penetrating radar (GPR) antenna. A total plane-wave scattering matrix is defined for the system consisting of the GPR antenna and the planar air-soil interface. The transmitting spectrum of the GPR antenna is expressed in terms...

  11. Impedance estimation of a finite absorber based on spherical array measurements

    DEFF Research Database (Denmark)

    Richard, Antoine Philippe André; Fernandez Grande, Efren; Brunskog, Jonas

    2016-01-01

    ’s impedance is inferred. The accuracy of the reconstruction is improved by using compressive sensing, where the wave field is represented with only a few components, ideally an incident and a reflected wave. However, at low frequencies, diffraction from the edges contributes considerably to the sound field...

  12. Inhibition of neuronal cell–cell adhesion measured by the microscopic aggregation assay and impedance sensing

    NARCIS (Netherlands)

    Wiertz, Remy; Marani, Enrico; Rutten, Wim

    2010-01-01

    Microscopic aggregation assay and impedance sensing (IS) were used to monitor a change in in vitro neuron–neuron adhesion in response to blocking of cell adhesion molecules. By blocking neuron–neuron adhesion, migration and aggregation of neuronal cells can be inhibited. This leads to better control

  13. Mechanical impedance and acoustic mobility measurement techniques of specifying vibration environments

    Science.gov (United States)

    Kao, G. C.

    1973-01-01

    Method has been developed for predicting interaction between components and corresponding support structures subjected to acoustic excitations. Force environments determined in spectral form are called force spectra. Force-spectra equation is determined based on one-dimensional structural impedance model.

  14. Measuring body composition in dogs using multifrequency bioelectrical impedance analysis and dual energy X-ray absorptiometry.

    Science.gov (United States)

    Rae, L S; Vankan, D M; Rand, J S; Flickinger, E A; Ward, L C

    2016-06-01

    Thirty-five healthy, neutered, mixed breed dogs were used to determine the ability of multifrequency bioelectrical impedance analysis (MFBIA) to predict accurately fat-free mass (FFM) in dogs using dual energy X-ray absorptiometry (DXA)-measured FFM as reference. A second aim was to compare MFBIA predictions with morphometric predictions. MFBIA-based predictors provided an accurate measure of FFM, within 1.5% when compared to DXA-derived FFM, in normal weight dogs. FFM estimates were most highly correlated with DXA-measured FFM when the prediction equation included resistance quotient, bodyweight, and body condition score. At the population level, the inclusion of impedance as a predictor variable did not add substantially to the predictive power achieved with morphometric variables alone; in individual dogs, impedance predictors were more valuable than morphometric predictors. These results indicate that, following further validation, MFBIA could provide a useful tool in clinical practice to objectively measure FFM in canine patients and help improve compliance with prevention and treatment programs for obesity in dogs.

  15. Electrochemical Impedance Spectroscopic Measurements of Sexithiophene-Effect of the Electrode Nature and the Dopant (CuCl2) Content

    Institute of Scientific and Technical Information of China (English)

    NESSARK,Belkacem; MAOUCHE,Na(i)ma

    2009-01-01

    Electrochemical impedance spectroscopic (EIS) measurements of sexithiophene (6T) were carried out according to the Pt/6T/M sandwich structure configuration,for various electrode materials (M=GC,ITO,Ag,Cu,AI) and for different doping levels of copper chloride (CuCl2).The results demonstrate that two types of charge transport are involved in the redox process at the electrode/6T interface and inside the bulk oligomer.The complex-plane impedance plots obtained for various doping levels of CuCl2 exhibit arc shapes.The charge-transfer resistance measured from the diagrams decreases systematically with the addition of the salt,leading to an increase of the oligothiophene conductivity.

  16. 同塔双回输电线路零序阻抗的测量及分析%Measurement and Analysis of the Zero Sequence Impedance of the Double Circuit Transmission Line

    Institute of Scientific and Technical Information of China (English)

    刘博; 卢明; 吕中宾; 杨晓辉; 杨威; 郭磊

    2011-01-01

    When the zero-sequence impedance of circuit I of the double circuit transmission line is measured, zero-sequence induced current will flow through the path composed of overhead ground wire, earth and another circuit II which is short connected and grounded in two ends and can be considered as shielding line with two terminals grounded , due to the mutual inductance between them. The path of those grounded lines is equivalent to a shorted secondary coil of circuit I and cause demagnetization on its magnetic field. The measured value of zero-sequence impedance amplitude will be reduced as a result of the path formed by those grounded lines and the zero-sequence impedance angle will also be affected. Inaccuracy can be caused by this measurement error of zero-sequence impedance to relay protective setting, power flow calculation and stability analysis. This article analyzes Double Circuit Transmission line with continuous ground zero sequence impedance grounding of the accuracy of measurement results,By EMTP of typical double-circuit transmission line tower with zero sequence impedance simulation, And analysis of the four 500 kV lines, two 220 kV lines, zero sequence impedance of the measured results, the measurement issues that should be noted, it puts forward some problems that should be paid attention to during the process of measurement and calculation.%同塔双回架空输电线路,测量I回线路零序阻抗,II回线路双端短路接地,其三相导线、地线与大地构成零序电流的通路,II回线路亦可等效为连续接地的避雷线,避雷线相当于I回线路的一个二次短路线圈,对I回线路磁场起去磁作用,引起I回线路零序阻抗幅值的降低和相角的变化.笔者理论分析同塔双回输电线路地线连续接地对零序阻抗测量结果准确性的影响,通过EMTP对典型同塔双回输电线路零序阻抗参数进行仿真计算,并且分析了4条500 kV线路、2条220 kV线路的零序阻抗实测结果,提

  17. AMS Ground Truth Measurements: Calibration and Test Lines

    Energy Technology Data Exchange (ETDEWEB)

    Wasiolek, P. [National Security Technologies, LLC. (NSTec), Mercury, NV (United States)

    2013-11-01

    Airborne gamma spectrometry is one of the primary techniques used to define the extent of ground contamination after a radiological incident. Its usefulness was demonstrated extensively during the response to the Fukushima nuclear power plant (NPP) accident in March-May 2011. To map ground contamination a set of scintillation detectors is mounted on an airborne platform (airplane or helicopter) and flown over contaminated areas. The acquisition system collects spectral information together with the aircraft position and altitude every second. To provide useful information to decision makers, the count rate data expressed in counts per second (cps) needs to be converted to the terrestrial component of the exposure rate 1 m above ground, or surface activity of isotopes of concern. This is done using conversion coefficients derived from calibration flights. During a large scale radiological event, multiple flights may be necessary and may require use of assets from different agencies. However, as the production of a single, consistent map product depicting the ground contamination is the primary goal, it is critical to establish very early into the event a common calibration line. Such a line should be flown periodically in order to normalize data collected from different aerial acquisition systems and potentially flown at different flight altitudes and speeds. In order to verify and validate individual aerial systems, the calibration line needs to be characterized in terms of ground truth measurements. This is especially important if the contamination is due to short-lived radionuclides. The process of establishing such a line, as well as necessary ground truth measurements, is described in this document.

  18. The Rover Environmental Monitoring Station Ground Temperature Sensor: A Pyrometer for Measuring Ground Temperature on Mars

    OpenAIRE

    2010-01-01

    We describe the parameters that drive the design and modeling of the Rover Environmental Monitoring Station (REMS) Ground Temperature Sensor (GTS), an instrument aboard NASA’s Mars Science Laboratory, and report preliminary test results. REMS GTS is a lightweight, low-power, and low cost pyrometer for measuring the Martian surface kinematic temperature. The sensor’s main feature is its innovative design, based on a simple mechanical structure with no moving parts. It includes an in-flight cal...

  19. How Does Measuring Generate Evidence? The Problem of Observational Grounding

    Science.gov (United States)

    Tal, Eran

    2016-11-01

    The epistemology of measurement is an area of philosophy that studies the relationships between measurement and knowledge. One of its central aims is to explain how measurement can function as a reliable source of scientific evidence. Key to such explanation is a clear characterization of the dependence of measurement on observation, but such characterization has remained elusive. This article traces the recent historical trajectory of views on the observational grounding of measurement, clarifies the current state of the problem, and proposes new directions for progress. Specifically, I argue in favour of viewing measurement outcomes as the best predictors of observed instrument indications under a given theoretical-statistical model of the measurement process. The evidential efficacy of measurement outcomes is explained by their relatively high epistemic security, rather than by their inferential or structural closeness to observation.

  20. A Novel Impedance Biosensor for Measurement of Trans-Epithelial Resistance in Cells Cultured on Nanofiber Scaffolds.

    Science.gov (United States)

    Schramm, Robert A; Koslow, Matthew H; Nelson, Deirdre A; Larsen, Melinda; Castracane, James

    2017-08-31

    Nanofibrous scaffolds provide high surface area for cell attachment, and resemble the structure of the collagen fibers which naturally occur in the basement membrane and extracellular matrix. A label free and non-destructive method of assessing the interaction of cell tissue and scaffolds aids in the ability to discern the effective quality and magnitude of any scaffold modifications. Impedance cell spectroscopy is a biosensing method that employs a functional approach to assessing the cell monolayer. The electrical impedance barrier function of a cell monolayer represents the level of restriction to diffusion of charged species between all adjacent cells across an entire contiguous cellular monolayer. The impedance signals from many individual paracellular pathways contribute to the bulk measurement of the whole monolayer barrier function. However, the scaffold substrate must be entirely porous in order to be used with electrochemical cell impedance spectroscopy (ECIS) and cells must be closely situated to the electrodes. For purposes of evaluating cell-scaffold constructs for tissue engineering, non-invasive evaluation of cell properties while seeded on scaffolds is critical. A Transwell-type assay makes a measurement across a semi-permeable membrane, using electrodes placed on opposing sides of the membrane immersed in fluid. It was found that by suspending a nanofiber scaffold across a Transwell aperture, it is possible to integrate a fully functional nanofiber tissue scaffold with the ECIS Transwell apparatus. Salivary epithelial cells were grown on the nanofiber scaffolds and tight junction formation was evaluated using ECIS measurements in parallel with immunostaining and confocal imaging. The trans-epithelial resistance increased coordinate with cell coverage, culminating with a cell monolayer, at which point the tight junction proteins assemble and strengthen, reaching the peak signal. These studies demonstrate that ECIS can be used to evaluate tight

  1. Measurements And Particle In Cell vs. Fluid Simulations Of A New Time Domain Impedance Probe For Ionospheric Plasma Characterization

    Science.gov (United States)

    Spencer, E. A.; Russ, S.; Kerrigan, B.; Leggett, K.; Mullins, J.; Clark, D. C.; Mizell, J.; Gollapalli, R.; Vassiliadis, D.; Lusk, G. D.

    2015-12-01

    A plasma impedance probe is used to obtain plasma parameters in the ionosphere by measuring the magnitude, shape and location of resonances in the frequency spectrum when a probe structure is driven with RF excitation. The measured magnitude and phase response with respect to frequency can be analyzed via analytical and simulational means. We have designed and developed a new Time Domain Impedance Probe capable of making measurements of absolute electron density and electron neutral collision frequency at temporal and spatial resolutions not previously attained. A single measurement can be made in a time as short as 50 microseconds, which yields a spatial resolution of 0.35 meters for a satellite orbital velocity of 7 km/s. The method essentially consists of applying a small amplitude time limited voltage signal into a probe and measuring the resulting current response. The frequency bandwidth of the voltage signal is selected in order that the electron plasma resonances are observable. A prototype of the instrument will be flown in October 2015 on a NASA Undergraduate Student Instrument Progam (USIP) sounding rocket launched out of Wallops Flight Facility. To analyze the measurements, we use a Particle In Cell (PIC) kinetic simulation to calculate the impedance of a dipole antenna immersed in a plasma. The electromagnetic solver utilizes the Finite Difference Time Domain method, while the particle to grid and grid to particle interpolation schemes are standard. The plasma sheath formation electron flux into the dipole surface is not included. The bulk velocity of the plasma around the dipole is assumed to be zero. For completeness, the hot plasma and nonlinear effects of probe plasma interaction are explored, including the appearance of cyclotron harmonics. In this work the electron neutral collisions are simulated via a Poisson process approximation. Our results are compared to sounding rocket data from the NASA Tropical Storms mission in 2007, as well as the

  2. Body fluid volumes measurements by impedance: A review of bioimpedance spectroscopy (BIS) and bioimpedance analysis (BIA) methods.

    Science.gov (United States)

    Jaffrin, Michel Y; Morel, Hélène

    2008-12-01

    This paper reviews various bioimpedance methods permitting to measure non-invasively, extracellular, intracellular and total body water (TBW) and compares BIA methods based on empirical equations of the wrist-ankle resistance or impedance at 50 kHz, height and weight with BIS methods which rely on an electrical model of tissues and resistances measured at zero and infinite frequencies. In order to compare these methods, impedance measurements were made with a multifrequency Xitron 4200 impedance meter on 57 healthy subjects which had undergone simultaneously a Dual X-ray absorptiometry examination (DXA), in order to estimate their TBW from their fat-free-mass. Extracellular (ECW) and TBW volumes were calculated for these subjects using the original BIS method and modifications of Matthie[Matthie JR. Second generation mixture theory equation for estimating intracellular water using bioimpedance spectroscopy. J Appl Physiol 2005;99:780-1], Jaffrin et al. [Jaffrin MY, Fenech M, Moreno MV, Kieffer R. Total body water measurement by a modification of the bioimpédance spectroscopy method. Med Bio Eng Comput 2006;44:873-82], Moissl et al. [Moissl UM, Wabel P, Chamney PW, Bosaeus I, Levin NW, et al. Body fluid volume determination via body composition spectroscopy in health and disease. Physiol Meas 2006;27:921-33] and their TBW resistivities were compared and discussed. ECW volumes were calculated by BIA methods of Sergi et al. [Sergi G, Bussolotto M, Perini P, Calliari I, et al. Accuracy of bioelectrical bioimpedance analysis for the assessment of extracellular space in healthy subjects and in fluid retention states. Ann Nutr Metab 1994;38(3):158-65] and Hannan et al. [Hannan WJ, Cowen SJ, Fearon KC, Plester CE, Falconer JS, Richardson RA. Evaluation of multi-frequency bio-impedance analysis for the assessment of extracellular and total body water in surgical patients. Clin Sci 1994;86:479-85] and TBW volumes by BIA methods of Kushner and Schoeller [Kushner RF

  3. Ground-based measurement of surface temperature and thermal emissivity

    Science.gov (United States)

    Owe, M.; Van De Griend, A. A.

    1994-01-01

    Motorized cable systems for transporting infrared thermometers have been used successfully during several international field campaigns. Systems may be configured with as many as four thermal sensors up to 9 m above the surface, and traverse a 30 m transect. Ground and canopy temperatures are important for solving the surface energy balance. The spatial variability of surface temperature is often great, so that averaged point measurements result in highly inaccurate areal estimates. The cable systems are ideal for quantifying both temporal and spatial variabilities. Thermal emissivity is also necessary for deriving the absolute physical temperature, and measurements may be made with a portable measuring box.

  4. Impedance-estimation methods, modeling methods, articles of manufacture, impedance-modeling devices, and estimated-impedance monitoring systems

    Science.gov (United States)

    Richardson, John G.

    2009-11-17

    An impedance estimation method includes measuring three or more impedances of an object having a periphery using three or more probes coupled to the periphery. The three or more impedance measurements are made at a first frequency. Three or more additional impedance measurements of the object are made using the three or more probes. The three or more additional impedance measurements are made at a second frequency different from the first frequency. An impedance of the object at a point within the periphery is estimated based on the impedance measurements and the additional impedance measurements.

  5. Smartphone-based portable biosensing system using impedance measurement with printed electrodes for 2,4,6-trinitrotoluene (TNT) detection.

    Science.gov (United States)

    Zhang, Diming; Jiang, Jing; Chen, Junye; Zhang, Qian; Lu, Yanli; Yao, Yao; Li, Shuang; Logan Liu, Gang; Liu, Qingjun

    2015-08-15

    Rapid, sensitive, selective and portable detection of 2,4,6-trinitrotoluene (TNT) is in high demand for public safety and environmental monitoring. In this study, we reported a smartphone-based system using impedance monitoring for TNT detection. The screen-printed electrodes modified with TNT-specific peptides were used as disposable a biosensor to produce impedance responses to TNT. The responses could be monitored by a hand-held device and send out to smartphone through Bluetooth. Then, the smartphone was used to display TNT responses in real time and report concentration finally. In the measurement, the system was demonstrated to detect TNT at concentration as low as 10(-6) M and distinguish TNT versus different chemicals in high specificity. Thus, the smartphone-based biosensing platform provided a convenient and efficient approach to design portable instruments for chemical detections such as TNT recognition. Copyright © 2015 Elsevier B.V. All rights reserved.

  6. Improved Sensing Pulses for Increased Human Head Depth Measurement Sensitivity With Electrical Impedance Spectroscopy

    Science.gov (United States)

    Lev, Michael H.

    2017-01-01

    This paper describes an improved electrical impedance spectroscopy (EIS) stimulus paradigm, based on dual-energy pulses using the stochastic Gabor function (SGF) that may more sensitively assess deep brain tissue impedance than current single-pulse paradigms. The SGF is a uniformly distributed noise, modulated by a Gaussian envelope, with a wide-frequency spectrum representation regardless of the stimuli energy, and is least compact in the sample frequency phase plane. Numerical results obtained using a realistic human head model confirm that two sequential SGF pulses at different energies can improve EIS depth sensitivity when used in a dual-energy subtraction scheme. Specifically, although the two SGF pulses exhibit different tissue current distributions, they maintain the broadband sensing pulse characteristics needed to generate all the frequencies of interest. Moreover, finite-difference time domain simulations show that this dual-energy excitation scheme is capable of reducing the amplitude of weighted current densities surface directly underneath the electrodes by approximately 3 million times versus single stimulation pulses, while maintaining an acceptable tissue conductivity distribution at depth. This increased sensitivity for the detection of small, deep impedance changes might be of value in potential future EIS applications, such as the portable, point-of-care detection of deep brain hemorrhage or infarction. PMID:24043365

  7. NO2 DOAS measurements from ground and space: comparison of ground based measurements and OMI data in Mexico City

    Science.gov (United States)

    Rivera, C.; Stremme, W.; Grutter, M.

    2012-04-01

    The combination of satellite data and ground based measurements can provide valuable information about atmospheric chemistry and air quality. In this work we present a comparison between measured ground based NO2 differential columns at the Universidad Nacional Autónoma de México (UNAM) in Mexico City, using the Differential Optical Absorption Spectroscopy (DOAS) technique and NO2 total columns measured by the Ozone Monitoring Instrument (OMI) onboard the Aura satellite using the same measurement technique. From these data, distribution maps of average NO2 above the Mexico basin were constructed and hot spots inside the city could be identified. In addition, a clear footprint was detected from the Tula industrial area, ~50 km northwest of Mexico City, where a refinery, a power plant and other industries are located. A less defined footprint was identified in the Cuernavaca basin, South of Mexico City, and the nearby cities of Toluca and Puebla do not present strong enhancements in the NO2 total columns. With this study we expect to cross-validate space and ground measurements and provide useful information for future studies.

  8. Electrothermal impedance spectroscopy as a cost efficient method for determining thermal parameters of lithium ion batteries: Prospects, measurement methods and the state of knowledge

    DEFF Research Database (Denmark)

    Swierczynski, Maciej Jozef; Stroe, Daniel Loan; Stanciu, Tiberiu;

    2016-01-01

    for parametrization. Recent research initiated by Barsoukov et al. proposed electrothermal impedance spectroscopy as a novel and non-destructive method of characterizing the thermal properties of batteries by defining frequency dependent thermal impedance. Despite its usefulness, the electrothermal impedance...... spectroscopy method can be still improved in terms of e.g. accuracy and measurement time and it has a potential to be extended to new applications. Performed review indicates that the electrothermal impedance spectroscopy is a very promising, non-destructive, simple and especially cost-efficient method...... for thermal characterization of batteries. The scientific intention of this paper is to collect and systematize the state of knowledge about electrothermal impedance spectroscopy and present different measurement methods on the example of a high-power lithium battery cell and finally to discuss the prospect....

  9. Optimal ground motion intensity measure for long-period structures

    Science.gov (United States)

    Guan, Minsheng; Du, Hongbiao; Cui, Jie; Zeng, Qingli; Jiang, Haibo

    2015-10-01

    This paper aims to select the most appropriate ground motion intensity measure (IM) that is used in selecting earthquake records for the dynamic time history analysis of long-period structures. For this purpose, six reinforced concrete frame-core wall structures, designed according to modern seismic codes, are studied through dynamic time history analyses with a set of twelve selected earthquake records. Twelve IMs and two types of seismic damage indices, namely, the maximum seismic response-based and energy-based parameters, are chosen as the examined indices. Selection criteria such as correlation, efficiency, and proficiency are considered in the selection process. The optimal IM is identified by means of a comprehensive evaluation using a large number of data of correlation, efficiency, and proficiency coefficients. Numerical results illustrate that peak ground velocity is the optimal one for long-period structures and peak ground displacement is also a close contender. As compared to previous reports, the spectral-correlated parameters can only be taken as moderate IMs. Moreover, the widely used peak ground acceleration in the current seismic codes is considered inappropriate for long-period structures.

  10. Ground-based Measurements of Next Generation Spectroradiometric Standard Stars

    Science.gov (United States)

    McGraw, John T.

    2013-01-01

    Accurate, radiometric standards are essential to the future of ground- and space-based astronomy and astrophysics. While astronomers tend to think of “standard stars” as available calibration sources, progress at NIST to accurately calibrate inexpensive, easy to use photodiode detectors as spectroradiometric standards from 200 nm to 1800 nm allows referencing astronomical measurements to these devices. Direction-, time-, and wavelength-dependent transmission of Earth’s atmosphere is the single largest source of error for ground-based radiometric measurement of astronomical objects. Measurements and impacts of atmospheric extinction - scattering and absorption - on imaging radiometric and spectroradiometric measurements are described. The conclusion is that accurate real-time measurement of extinction in the column of atmosphere through which standard star observations are made, over the spectral region being observed and over the field of view of the telescope are required. New techniques to directly and simultaneously measure extinction in the column of atmosphere through which observations are made are required. Our direct extinction measurement solution employs three small facility-class instruments working in parallel: a lidar to measure rapidly time variable transmission at three wavelengths with uncertainty of 0.25% per airmass, a spectrophotometer to measure rapidly wavelength variable extinction with sub-1% precision per nanometer resolution element from 350 to 1050nm, and a wide-field camera to measure angularly variable extinction over the field of view. These instruments and their operation will be described. We assert that application of atmospheric metadata provided by this instrument suite corrects for a significant fraction of systematic errors currently limiting radiometric precision, and provides a major step towards measurements that are provably dominated by random noise.

  11. Measurement of Characteristic Impedance of Silicon Fiber Sheet based readout strips panel for RPC detector in INO

    CERN Document Server

    Singh, M K; Marimuthu, N; Singh, V; Subrahmanyam, V S

    2016-01-01

    The India based Neutrino Observatory (INO) is a mega science project of India, which is going to use near about 30, 000 Resistive Plate Chambers (RPC) as active detector elements for the study of atmospheric neutrino oscillations. Each RPC detector will consist of two orthogonally placed readout strips panel for picking the signals generated in the gas chamber. The area of RPC detector in INO-ICAL (Iron Calorimeter) experiment will be 2m x 2m, therefore the dimension of readout strips panel will also be of 2m x 2m. To get undistorted signals pass through the readout strips panel to frontend electronics, their Characteristic Impedance should be matched with each other. For the matching of Characteristic Impedance we have used the principle of termination. In the present paper we will describe the need and search of new dielectric material for the fabrication of flame resistant, waterproof and flexible readout pickup strips panel. We will also describe the measurement of Characteristic Impedance of plastic hone...

  12. Measurement of characteristic impedance of silicon fiber sheet based readout strip panel for RPC detector in INO

    Science.gov (United States)

    Singh, M. K.; Kumar, A.; Marimuthu, N.; Singh, V.; Subrahmanyam, V. S.

    2017-01-01

    The India-based Neutrino Observatory (INO) is a mega science project of India, which is going to use about 30,000 Resistive Plate Chambers (RPC) as active detector elements for the study of atmoshpheric neutrino oscillations. Each RPC detector will consist of two orthogonally placed readout strip panel for picking the signals generated in the gas chamber. The area of RPC detector in INO-ICAL (Iron Calorimeter) experiment will be 2 m × 2 m, therefore the dimensions of readout strip panel should also be 2 m × 2 m. To get undistorted signals pass through the readout strip panel to front-end electronics, their characteristic impedance should be matched with each other. In the present paper, we describe the need and search of new dielectric material for the fabrication of flame resistant, waterproof and flexible readout strip panel. We will also describe the measurement of characteristic impedance of Plastic Honeycomb (PH) based readout strip panel and Silicon Fiber Sheet (SFS) based readout strip panel in a comparative way, and its variation under loading and with time. Based on this study, we found that a 5 mm thick SFS-based readout strip panel has a minimum signal reflection at 49.5 ohm characteristic impedance value. Our study shows that SFS is a good dielectric material for the purpose.

  13. Impact of exacerbations on respiratory system impedance measured by a forced oscillation technique in COPD: a prospective observational study

    Science.gov (United States)

    Kamada, Takahiro; Kaneko, Masahiro; Tomioka, Hiromi

    2017-01-01

    Background Forced oscillation technique (FOT) has been reported to be useful in the evaluation and management of obstructive lung disease, including COPD. To date, no data are available concerning long-term changes in respiratory system impedance measured by FOT. Additionally, although exacerbations have been reported to be associated with excessive lung function decline in COPD, the impact of exacerbations on the results of FOT has not been demonstrated. The aim of this study was to investigate the longitudinal changes in respiratory system impedance and the influence of exacerbations thereon. Methods Between March 2011 and March 2012, outpatients who attended Kobe City Medical Center West Hospital with a diagnosis of COPD were assessed for eligibility. Baseline patient characteristics (age, sex, body mass index, smoking history, current smoking status, COPD stage), lung function (post-bronchodilator forced expiratory volume in 1 second [FEV1]), blood tests (neutrophils and eosinophils), FOT, and COPD assessment test results were collected at enrollment. Lung function and FOT were examined every 6 months until March 2016. Annual changes in FEV1 and FOT parameters were obtained from the slope of the linear regression curve. The patients were divided into 2 groups based on exacerbation history. Results Fifty-one of 58 patients with COPD were enrolled in this study. The median follow-up period was 57 (52–59) months. Twenty-five (49%) patients experienced exacerbations. A significant annual decline in FEV1 and respiratory system impedance were shown. Additionally, annual changes in FEV1, respiratory system resistance at 5 Hz, respiratory system reactance at 5 Hz, and resonant frequency were greater in patients with exacerbations than in those without exacerbations. Conclusion Exacerbations of COPD lead not only to a decline in lung function but also to an increase in respiratory system impedance.

  14. Input impedance and mutual coupling of rectangular microstrip antennas

    Science.gov (United States)

    Pozar, D. M.

    1982-01-01

    A moment method solution to the problem of input impedance and mutual coupling of rectangular microstrip antenna elements is presented. The formulation uses the grounded dielectric slab Green's function to account rigorously for the presence of the substrate and surface waves. Both entire basis (EB) and piecewise sinusoidal (PWS) expansion modes are used, and their relative advantages are noted. Calculations of input impedance and mutual coupling are compared with measured data and other calculations.

  15. Systematic review of ground reaction force measurements in cats.

    Science.gov (United States)

    Schnabl, E; Bockstahler, B

    2015-10-01

    Although orthopaedic abnormalities in cats are frequently observed radiographically, they remain clinically underdiagnosed, and kinetic motion analysis, a fundamental aspect of orthopaedic research in dogs and horses, is not commonly performed. More information obtained with non-invasive measurement techniques to assess normal and abnormal gait in cats would provide a greater insight into their locomotion and biomechanics and improve the objective measurement of disease alterations and treatment modalities. In this systematic review, 12 previously performed studies that investigated ground reaction force measurements in cats during locomotion were evaluated. The aims of these studies, the measurement methods and equipment used, and the outcomes of parameters used to assess both sound and diseased cats are summarised and discussed. All reviewed studies used pressure sensitive walkways to gain data and all provided an acclimatisation period as a prerequisite for measurements. In sound cats during walking, the forelimb peak vertical force was greater than in the hindlimb and the peak vertical force in the hindlimb was greater in cats than in dogs. This review confirms that ground reaction forces can be used to evaluate lameness and treatment effects in the cat.

  16. The electrical properties of Titan's surface at the Huygens landing site measured with the PWA-HASI Mutual Impedance Probe. New approach and new findings

    Science.gov (United States)

    Hamelin, Michel; Lethuillier, Anthony; Le Gall, Alice; Grard, Réjean; Béghin, Christian; Schwingenschuh, Konrad; Jernej, Irmgard; López-Moreno, José-Juan; Brown, Vic; Lorenz, Ralph D.; Ferri, Francesca; Ciarletti, Valérie

    2016-05-01

    Ten years after the successful landing of the Huygens Probe on the surface of Titan, we reassess the derivation of ground complex permittivity using the PWA-MIP/HASI measurements (Permittivity, Waves and Altimetry-Mutual Impedance Probe/Huygens Atmospheric Structure Instrument) at the frequencies 45, 90 and 360 Hz. For this purpose, we have developed a numerical method, namely "the capacity-influence matrix method", able to account for new insights on the Huygens Probe attitude at its final resting position. We find that the surface of Titan at the landing site has a dielectric constant of 2.5 ± 0.3 and a conductivity of 1.2 ± 0.6 nS/m, in agreement with previously published results but with much more reliable error estimates. These values speak in favour of a photochemical origin of the material in the first meter of the subsurface. We also propose, for the first time, a plausible explanation for the sudden change observed by PWA-MIP ∼11 min after landing: this change corresponds to a drop in the ground conductivity, probably due to the removal of a superficial conductive layer in association with the release of volatile materials warmed by the Huygens Probe.

  17. Measurement of Small Molecule Binding Kinetics on a Protein Microarray by Plasmonic-Based Electrochemical Impedance Imaging

    Science.gov (United States)

    2015-01-01

    We report on a quantitative study of small molecule binding kinetics on protein microarrays with plasmonic-based electrochemical impedance microscopy (P-EIM). P-EIM measures electrical impedance optically with high spatial resolution by converting a surface charge change to a surface plasmon resonance (SPR) image intensity change, and the signal is not scaled to the mass of the analyte. Using P-EIM, we measured binding kinetics and affinity between small molecule drugs (imatinib and SB202190) and their target proteins (kinases Abl1 and p38-α). The measured affinity values are consistent with reported values measured by an indirect competitive binding assay. We also found that SB202190 has weak bindings to ABL1 with KD > 10 μM, which is not reported in the literature. Furthermore, we found that P-EIM is less prone to nonspecific binding, a long-standing issue in SPR. Our results show that P-EIM is a novel method for high-throughput measurement of small molecule binding kinetics and affinity, which is critical to the understanding of small molecules in biological systems and discovery of small molecule drugs. PMID:25153794

  18. Ventilation distribution in rats: Part I - The effect of gas composition as measured with electrical impedance tomography

    Directory of Open Access Journals (Sweden)

    Dunster Kimble R

    2012-09-01

    Full Text Available Abstract The measurement of ventilation distribution is currently performed using inhaled tracer gases for multiple breath inhalation studies or imaging techniques to quantify spatial gas distribution. Most tracer gases used for these studies have properties different from that of air. The effect of gas density on regional ventilation distribution has not been studied. This study aimed to measure the effect of gas density on regional ventilation distribution. Methods Ventilation distribution was measured in seven rats using electrical impedance tomography (EIT in supine, prone, left and right lateral positions while being mechanically ventilated with either air, heliox (30% oxygen, 70% helium or sulfur hexafluoride (20% SF6, 20% oxygen, 60% air. The effect of gas density on regional ventilation distribution was assessed. Results Gas density did not impact on regional ventilation distribution. The non-dependent lung was better ventilated in all four body positions. Gas density had no further impact on regional filling characteristics. The filling characteristics followed an anatomical pattern with the anterior and left lung showing a greater impedance change during the initial phase of the inspiration. Conclusion It was shown that gas density did not impact on convection dependent ventilation distribution in rats measured with EIT.

  19. Impedance Scaling and Impedance Control

    Energy Technology Data Exchange (ETDEWEB)

    Chou, W.; Griffin, J.

    1997-06-01

    When a machine becomes really large, such as the Very Large Hadron Collider (VLHC), of which the circumference could reach the order of megameters, beam instability could be an essential bottleneck. This paper studies the scaling of the instability threshold vs. machine size when the coupling impedance scales in a ``normal`` way. It is shown that the beam would be intrinsically unstable for the VLHC. As a possible solution to this problem, it is proposed to introduce local impedance inserts for controlling the machine impedance. In the longitudinal plane, this could be done by using a heavily detuned rf cavity (e.g., a biconical structure), which could provide large imaginary impedance with the right sign (i.e., inductive or capacitive) while keeping the real part small. In the transverse direction, a carefully designed variation of the cross section of a beam pipe could generate negative impedance that would partially compensate the transverse impedance in one plane.

  20. Body composition measurement: a review of hydrodensitometry, anthropometry, and impedance methods.

    Science.gov (United States)

    Brodie, D; Moscrip, V; Hutcheon, R

    1998-03-01

    Human body composition is an expression of genetic and nutritional factors. It can change as a consequence of exogenous influences such as training, disease, or diet and is therefore of particular interest to nutrition professionals. Two of the main methods of estimating body composition in this review (hydrodensitometry and anthropometry) have been in use for decades, but the third method (bioelectrical impedance) is more recent. The procedure, theoretical basis, assumptions, standard error of estimates, and comparisons with other techniques are presented for each of the three methods. References to general and specific populations are presented that illustrate regression equations for different ages, ethnic groups, and gender. The advantages and disadvantages of the three methods are reviewed with reference made to the alternative compartment models. Other methods (DEXA, infrared interactance) are briefly reviewed.

  1. Electrical measurement of magnetic-field-impeded polarity switching of a ferromagnetic vortex core

    Science.gov (United States)

    Sushruth, Manu; Fried, Jasper P.; Anane, Abdelmadjid; Xavier, Stephane; Deranlot, Cyril; Kostylev, Mikhail; Cros, Vincent; Metaxas, Peter J.

    2016-09-01

    Vortex core polarity switching in NiFe disks has been evidenced using an all-electrical magnetoresistive rectification scheme. Simulation and experiments yield a consistent rectified signal loss when driving core gyration at high powers. With increasing power, the frequency range over which the loss occurs grows and the resonance downshifts in frequency, consistent with nonlinear core dynamics and periodic core polarity switching induced by the core reaching its critical velocity. Core-polarity-dependent rectification signals enable an independent verification of the switched core polarity. We also demonstrate the ability to impede core polarity switching by displacing the core towards the disk's edge where an increased core stiffness reduces the core velocity.

  2. Quantitative angle-resolved small-spot reflectance measurements on plasmonic perfect absorbers: impedance matching and disorder effects.

    Science.gov (United States)

    Tittl, Andreas; Harats, Moshe G; Walter, Ramon; Yin, Xinghui; Schäferling, Martin; Liu, Na; Rapaport, Ronen; Giessen, Harald

    2014-10-28

    Plasmonic devices with absorbance close to unity have emerged as essential building blocks for a multitude of technological applications ranging from trace gas detection to infrared imaging. A crucial requirement for such elements is the angle independence of the absorptive performance. In this work, we develop theoretically and verify experimentally a quantitative model for the angular behavior of plasmonic perfect absorber structures based on an optical impedance matching picture. To achieve this, we utilize a simple and elegant k-space measurement technique to record quantitative angle-resolved reflectance measurements on various perfect absorber structures. Particularly, this method allows quantitative reflectance measurements on samples where only small areas have been nanostructured, for example, by electron-beam lithography. Combining these results with extensive numerical modeling, we find that matching of both the real and imaginary parts of the optical impedance is crucial to obtain perfect absorption over a large angular range. Furthermore, we successfully apply our model to the angular dispersion of perfect absorber geometries with disordered plasmonic elements as a favorable alternative to current array-based designs.

  3. An EIS alternative for impedance measurement of a high temperature PEM fuel cell stack based on current pulse injection

    DEFF Research Database (Denmark)

    Jeppesen, Christian; Araya, Samuel Simon; Sahlin, Simon Lennart

    2017-01-01

    In this paper a method for estimating the fuel cell impedance is presented, namely the current pulse injection (CPI) method, which is well suited for online implementation. This method estimates the fuel cell impedance and unlike electrochemical impedance spectroscopy (EIS), it is simple to imple...

  4. The Rover Environmental Monitoring Station Ground Temperature Sensor: A Pyrometer for Measuring Ground Temperature on Mars

    Directory of Open Access Journals (Sweden)

    Miguel Ramos

    2010-10-01

    Full Text Available We describe the parameters that drive the design and modeling of the Rover Environmental Monitoring Station (REMS Ground Temperature Sensor (GTS, an instrument aboard NASA’s Mars Science Laboratory, and report preliminary test results. REMS GTS is a lightweight, low-power, and low cost pyrometer for measuring the Martian surface kinematic temperature. The sensor’s main feature is its innovative design, based on a simple mechanical structure with no moving parts. It includes an in-flight calibration system that permits sensor recalibration when sensor sensitivity has been degraded by deposition of dust over the optics. This paper provides the first results of a GTS engineering model working in a Martian-like, extreme environment.

  5. Directed weighted network structure analysis of complex impedance measurements for characterizing oil-in-water bubbly flow

    Science.gov (United States)

    Gao, Zhong-Ke; Dang, Wei-Dong; Xue, Le; Zhang, Shan-Shan

    2017-03-01

    Characterizing the flow structure underlying the evolution of oil-in-water bubbly flow remains a contemporary challenge of great interests and complexity. In particular, the oil droplets dispersing in a water continuum with diverse size make the study of oil-in-water bubbly flow really difficult. To study this issue, we first design a novel complex impedance sensor and systematically conduct vertical oil-water flow experiments. Based on the multivariate complex impedance measurements, we define modalities associated with the spatial transient flow structures and construct modality transition-based network for each flow condition to study the evolution of flow structures. In order to reveal the unique flow structures underlying the oil-in-water bubbly flow, we filter the inferred modality transition-based network by removing the edges with small weight and resulting isolated nodes. Then, the weighted clustering coefficient entropy and weighted average path length are employed for quantitatively assessing the original network and filtered network. The differences in network measures enable to efficiently characterize the evolution of the oil-in-water bubbly flow structures.

  6. The LEP impedance model

    Energy Technology Data Exchange (ETDEWEB)

    Zotter, B. [European Organization for Nuclear Research, Geneva (Switzerland)

    1996-08-01

    This report describes a number of measurements and computations of the impedance of the Large Electron Positron collider LEP at CERN. The work has been performed over several years, together with D. Brandt, K. Cornelis, A. Hofmann, G. Sabbi and many others. The agreement between measurements of single bunch instabilities on the machine and computer simulations is in general excellent and gives confidence in the impedance model used. (author)

  7. Impedance measurement and modelling of super-capacitors for railway applications

    Energy Technology Data Exchange (ETDEWEB)

    Hammar, A.; Chabas, J. [Societe Nationale des Chemins de fer Francais (SNCF), Dir. de la Recherche, 75 - Paris (France); Coquery, G.; Lallemand, R. [Institut National de Recherche sur les Transports et leur Securite (INRETS), Lab. des Technologies Nouvelles, 94 - Arcueil (France); Rojat, G.; Venet, P. [Lyon-1 Univ. Claude Bernard, CEGELY, 69 - Villeurbanne (France)

    2004-07-01

    Railways and electrical traction systems require high power rates to achieve their operating performances. Systems of power supply based on super-capacitors should offer high power density along with good energy efficiency and expected operating safety. We investigate general behaviours of super-capacitors with two powerful methods of analysis. The first is constant charge/discharge current at high level value (500 A), the second is impedance spectroscopy which leads to the acquisition of a set of parameters that are considered sufficient to describe general properties of super-capacitor, in particular the state of health and the available energy in any operating conditions. An electrical circuit model is defined for super-capacitors based on activated carbon and organic electrolyte. It takes into account the dependence of super-capacitor to voltage and current. The mixture of data of the two methods permits to obtain a representative model for power applications. Matlab/Simulink simulations are shown to verify the validity of the model. (authors)

  8. Broadband 120 MHz Impedance Quartz Crystal Microbalance (QCM with Calibrated Resistance and Quantitative Dissipation for Biosensing Measurements at Higher Harmonic Frequencies

    Directory of Open Access Journals (Sweden)

    Manuel Kasper

    2016-05-01

    Full Text Available We developed an impedance quartz crystal microbalance (QCM approach with the ability to simultaneously record mass changes and calibrated energy dissipation with high sensitivity using an impedance analyzer. This impedance QCM measures frequency shifts and resistance changes of sensing quartz crystals very stable, accurately, and calibrated, thus yielding quantitative information on mass changes and dissipation. Resistance changes below 0.3 Ω were measured with corresponding dissipation values of 0.01 µU (micro dissipation units. The broadband impedance capabilities allow measurements between 20 Hz and 120 MHz including higher harmonic modes of up to 11th order for a 10 MHz fundamental resonance frequency quartz crystal. We demonstrate the adsorbed mass, calibrated resistance, and quantitative dissipation measurements on two biological systems including the high affinity based avidin-biotin interaction and nano-assemblies of polyelectrolyte layers. The binding affinity of a protein-antibody interaction was determined. The impedance QCM is a versatile and simple method for accurate and calibrated resistance and dissipation measurements with broadband measurement capabilities for higher harmonics measurements.

  9. RF Surface Impedance Measurement of Polycrystalline and Large Grain Nb Disk Sample at 7.5 GHz

    Energy Technology Data Exchange (ETDEWEB)

    Xiao, Binping [BNL; Geng, Rongli [JLAB; Kelley, Michael J. [W& M, JLAB; Marhauser, Frank [JLAB; Phillips, H. Larry [JLAB; Reece, Charles E. [JLAB; Wang, Haipeng [JLAB

    2009-11-01

    A Surface Impedance Characterization (SIC) system has been proposed at the 2005 SRF workshop and recently updated as detailed at the 2009 PAC conference. Currently the SIC system can measure samples in a temperature range from 2K to 20K exposed to an RF magnetic flux density of less than 3mT. We report on new results of a BCP etched large grain Nb sample measured with this system as compared with previous results of a BCP etched polycrystalline Nb sample. The design of an upgraded SIC system for use at higher magnetic flux densities is on the way to more efficiently investigate correlations between local material characteristics and associated SRF properties, both for preparation studies of bulk niobium and also new thin film SRF developments.

  10. Does an instrumented treadmill correctly measure the ground reaction forces?

    Directory of Open Access Journals (Sweden)

    Patrick A. Willems

    2013-11-01

    Since the 1990s, treadmills have been equipped with multi-axis force transducers to measure the three components of the ground reaction forces during walking and running. These measurements are correctly performed if the whole treadmill (including the motor is mounted on the transducers. In this case, the acceleration of the treadmill centre of mass relative to the reference frame of the laboratory is nil. The external forces exerted on one side of the treadmill are thus equal in magnitude and opposite in direction to the external forces exerted on the other side. However, uncertainty exists about the accuracy of these measures: due to friction between the belt and the tread-surface, due to the motor pulling the belt, some believe that it is not possible to correctly measure the horizontal components of the forces exerted by the feet on the belt. Here, we propose a simple model of an instrumented treadmill and we demonstrate (1 that the forces exerted by the subject moving on the upper part of the treadmill are accurately transmitted to the transducers placed under it and (2 that all internal forces – including friction – between the parts of the treadmill are cancelling each other.

  11. Measured ground-surface movements, Cerro Prieto geothermal field

    Energy Technology Data Exchange (ETDEWEB)

    Massey, B.L.

    1981-01-01

    The Cerro Prieto geothermal area in the Mexicali Valley, 30 kilometers southeast of Mexicali, Baja California, incurred slight deformation because of the extraction of hot water and steam, and probably, active tectonism. During 1977 to 1978, the US Geological Survey established and measured two networks of horizontal control in an effort to define both types of movement. These networks consisted of: (1) a regional trilateration net brought into the mountain ranges west of the geothermal area from stations on an existing US Geological Survey crustal-strain network north of the international border; and (2) a local net tied to stations in the regional net and encompassing the present and planned geothermal production area. Electronic distance measuring instruments were used to measure the distances between stations in both networks in 1978, 1979 and 1981. Lines in the regional net averaged 25 km. in length and the standard deviation of an individual measurement is estimated to be approx. 0.3 part per million of line length. The local network was measured using different instrumentation and techniques. The average line length was about 5 km. and the standard deviation of an individual measurement approached 3 parts per million per line length. Ground-surface movements in the regional net, as measured by both the 1979 and 1981 resurveys, were small and did not exceed the noise level. The 1979 resurvey of the local net showed an apparent movement of 2 to 3 centimeters inward toward the center of the production area. This apparent movement was restricted to the general limits of the production area. The 1981 resurvey of the local net did not show increased movement attributable to fluid extraction.

  12. Measurement of changes in impedance of DNA nanowires due to radiation induced structural damage. A novel approach for a DNA-based radiosensitive device

    Science.gov (United States)

    Heimbach, Florian; Arndt, Alexander; Nettelbeck, Heidi; Langner, Frank; Giesen, Ulrich; Rabus, Hans; Sellner, Stefan; Toppari, Jussi; Shen, Boxuan; Baek, Woon Yong

    2017-08-01

    The ability of DNA to conduct electric current has been the topic of numerous investigations over the past few decades. Those investigations indicate that this ability is dependent on the molecular structure of the DNA. Radiation-induced damages, which lead to an alteration of the molecular structure, should therefore change the electrical impedance of a DNA molecule. In this paper, the damage due to ionising radiation is shown to have a direct effect on the electrical transport properties of DNA. Impedance measurements of DNA samples were carried out by an AC impedance spectrometer before, during and after irradiation. The samples comprised of DNA segments, which were immobilized between gold electrodes with a gap of 12 μm. The impedance of all DNA samples exhibited rising capacitive behaviour with increasing absorbed dose.

  13. Eruption column height: a comparison between ground and satellite measurements

    Science.gov (United States)

    Scollo, Simona; Prestifilippo, Michele; Pecora, Emilio; Corradini, Stefano; Merucci, Luca; Spata, Gaetano; Coltelli, Mauro

    2014-05-01

    The eruption column height estimation is an essential parameter to evaluate the total mass eruption rate, the gas and aerosol plume dispersal and retrievals. The column height may be estimated using different systems (e.g. satellite, aircraft and ground observations) which may present marked differences. In this work we use the calibrated images collected by the video-surveillance system of the Istituto Nazionale di Geofisica e Vulcanologia, Osservatorio Etneo, from the visible camera located in Catania, 27 km from the vent. The analysis is carried out on twenty lava fountains from the New South East Crater during the recent Etna explosive activity. Firstly, we calibrated the camera to estimate its intrinsic parameters and the full camera model. Furthermore, we selected the images which recorded the maximum phase of the eruptive activity. Hence, we applied an appropriate correction to take into account the wind effect. The column height was also evaluated using SEVIRI and MODIS satellite images collected at the same time of the video camera measurements. The satellite column height retrievals is realized by comparing the 11 μm brightness temperature of the most opaque plume pixels with the atmospheric temperature profile measured at Trapani WMO Meteo station (the nearest WMO station to the Etnean area). The comparison between satellite and ground data show a good agreement and the column altitudes ranges between 7.5 and 9 km (upper limit of the camera system). For nine events we evaluated also the thickness of the volcanic plumes in the umbrella region (near the vent) which ranges between 2 and 3 km. The proposed approach help to quantitatively evaluate the column height that may be used by volcanic ash dispersal and sedimentation models for improving forecasts and reducing risks to aviation during volcanic crisis.

  14. Ground and Airborne Methane Measurements Using Optical Parametric Amplifiers

    Science.gov (United States)

    Numata, Kenji; Riris, Haris; Li, Steve; Wu, Stewart; Kawa, Stephan R.; Abshire, James Brice; Dawsey, Martha; Ramanathan, Anand

    2011-01-01

    We report on ground and airborne methane measurements with an active sensing instrument using widely tunable, seeded optical parametric generation (OPG). The technique has been used to measure methane, CO2, water vapor, and other trace gases in the near and mid-infrared spectral regions. Methane is a strong greenhouse gas on Earth and it is also a potential biogenic marker on Mars and other planetary bodies. Methane in the Earth's atmosphere survives for a shorter time than CO2 but its impact on climate change can be larger than CO2. Carbon and methane emissions from land are expected to increase as permafrost melts exposing millennial-age carbon stocks to respiration (aerobic-CO2 and anaerobic-CH4) and fires. Methane emissions from c1athrates in the Arctic Ocean and on land are also likely to respond to climate warming. However, there is considerable uncertainty in present Arctic flux levels, as well as how fluxes will change with the changing environment. For Mars, methane measurements are of great interest because of its potential as a strong biogenic marker. A remote sensing instrument that can measure day and night over all seasons and latitudes can localize sources of biogenic gas plumes produced by subsurface chemistry or biology, and aid in the search for extra-terrestrial life. In this paper we report on remote sensing measurements of methane using a high peak power, widely tunable optical parametric generator (OPG) operating at 3.3 micrometers and 1.65 micrometers. We have demonstrated detection of methane at 3.3 micrometers and 1650 nanometers in an open path and compared them to accepted standards. We also report on preliminary airborne demonstration of methane measurements at 1.65 micrometers.

  15. Bridge Network for Measuring Very Small Impedances from 4.2 to 300 degrees K with a Null-Detector Sensitivity of 10-11 Volt

    DEFF Research Database (Denmark)

    Bak, Christen Kjeldahl; Dalsgaard, Erik

    1967-01-01

    An ac measuring technique devised primarily for measuring galvanomagnetic effects in metals is presented. The instrument may, however, be useful whenever it is desired to measure and record continuously impedances in the range 10−3 to 10−8 Omega. The sample assembly is disscussed in some detail...

  16. Evaluation of bioelectrical impedance analysis (BIA) to measure condition and energy allocated to reproduction in marine fishes

    Science.gov (United States)

    Fitzhugh, G. R.; Wuenschel, M. J.; McBride, R. S.

    2010-04-01

    Reliable estimates of fish energy density at specific times prior to spawning may provide suitable proxies for egg production, and thereby help to explain some of the observed annual variation in recruits per spawner. Our goal is to develop and test modifications of BIA technology to measure energy allocation to reproduction for a variety of marine fishes. To date, a newly developed measuring board and probe system stabilized readings, which was demonstrated by a significant reduction in the coefficients of variation for impedance measures. Total body water, wet and dry weights could be predicted with very good precision (r2 = 0.92-0.99) using BIA measures of reactance or resistance for a number of finfish species. While constituent relationships (e.g. body water- body mass functions) did not differ seasonally, we did find that BIA measures are sensitive to body composition changes related to the seasonal spawning cycle. In an examination of monthly samples of tilefish, phase angle decreased below 15° in post-spawning (regressed) females. Such a monthly trend, which suggests available energy had decreased following the spawning season, was not evident from other, more traditional measures of condition including body-muscle water content, Fulton's K or ordinal measures of fat deposition (such as mesenteric fat). These preliminary results show that BIA technology is a promising application for tracking and efficiently predicting energetic condition of marine fishes.

  17. Electrochemical Performance and Stability of the Cathode for Solid Oxide Fuel Cells. I. Cross Validation of Polarization Measurements by Impedance Spectroscopy and Current-Potential Sweep

    Energy Technology Data Exchange (ETDEWEB)

    Zhou, Xiao Dong; Pederson, Larry R.; Templeton, Jared W.; Stevenson, Jeffry W.

    2009-12-09

    The aim of this paper is to address three issues in solid oxide fuel cells: (1) cross-validation of the polarization of a single cell measured using both dc and ac approaches, (2) the precise determination of the total areal specific resistance (ASR), and (3) understanding cathode polarization with LSCF cathodes. The ASR of a solid oxide fuel cell is a dynamic property, meaning that it changes with current density. The ASR measured using ac impedance spectroscopy (low frequency interception with real Z´ axis of ac impedance spectrum) matches with that measured from a dc IV sweep (the tangent of dc i-V curve). Due to the dynamic nature of ASR, we found that an ac impedance spectrum measured under open circuit voltage or on a half cell may not represent cathode performance under real operating conditions, particularly at high current density. In this work, the electrode polarization was governed by the cathode activation polarization; the anode contribution was negligible.

  18. Measurement of the axial force during primary peristalsis in the oesophagus using a novel electrical impedance technology.

    Science.gov (United States)

    Gravesen, F H; McMahon, B P; Drewes, A M; Gregersen, H

    2008-03-01

    The oesophagus serves to transport food and fluid from the pharynx to the stomach. Oesophageal function is usually evaluated by means of manometry which is a proxy of the force in the radial direction. However, force measurements in the axial direction will provide a better measure of oesophageal transport function. The aim of this study was to develop a probe based on electrical impedance measurements to quantify the axial force generated by oesophageal contractions, i.e. probe elongation was associated with the axial force. Calibration with weights up to 200 g was done. The dispersion, creep, temperature and bending dependence were studied at the bench. Subsequently, the probe was tested in vivo in a healthy human volunteer. The probe showed good reproducibility and the dispersion was <0.04. Some dependence on temperature, creep and bending was found. Interpolation of the calibration curves made it possible to compensate for temperature fluctuations. The maximum deviation was 6.1 +/- 3.7% at loads of 50 g. The influence of creep showed a maximum net creep of 6.1 g after 8 s. The swallowed bolus size correlated with the axial force measurements (P = 0.038) but not with manometric measurements. In conclusion, the new technique measures axial force in the oesophagus and may in the future provide valuable information about oesophageal function.

  19. The potential of ground gravity measurements to validate GRACE data

    Directory of Open Access Journals (Sweden)

    D. Crossley

    2003-01-01

    Full Text Available New satellite missions are returning high precision, time-varying, satellite measurements of the Earth’s gravity field. The GRACE mission is now in its calibration/- validation phase and first results of the gravity field solutions are imminent. We consider here the possibility of external validation using data from the superconducting gravimeters in the European sub-array of the Global Geodynamics Project (GGP as ‘ground truth’ for comparison with GRACE. This is a pilot study in which we use 14 months of 1-hour data from the beginning of GGP (1 July 1997 to 30 August 1998, when the Potsdam instrument was relocated to South Africa. There are 7 stations clustered in west central Europe, and one station, Metsahovi in Finland. We remove local tides, polar motion, local and global air pressure, and instrument drift and then decimate to 6-hour samples. We see large variations in the time series of 5–10µgal between even some neighboring stations, but there are also common features that correlate well over the 427-day period. The 8 stations are used to interpolate a minimum curvature (gridded surface that extends over the geographical region. This surface shows time and spatial coherency at the level of 2– 4µgal over the first half of the data and 1–2µgal over the latter half. The mean value of the surface clearly shows a rise in European gravity of about 3µgal over the first 150 days and a fairly constant value for the rest of the data. The accuracy of this mean is estimated at 1µgal, which compares favorably with GRACE predictions for wavelengths of 500 km or less. Preliminary studies of hydrology loading over Western Europe shows the difficulty of correlating the local hydrology, which can be highly variable, with large-scale gravity variations.Key words. GRACE, satellite gravity, superconducting gravimeter, GGP, ground truth

  20. Evaluation of the electrode performance for PAFC by using acid absorption, acceleration and ac-impedance measurement

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Chang-Soo; Song, Rak-Hyun; Choi, Byung-Woo [Korea Institute of Energy Research, Taejon (Korea, Republic of)] [and others

    1996-12-31

    In PAFC, the degradation on cathode electrode caused by carbon corrosion, platinum dissolution and growth is especially severe. An acceleration test is a good technique for evaluating the degradation of electrode performance, because it does not need long time. Coleman et al used thermal cycling and on-off cycling as an acceleration test. Song et al showed that hydrogen shortage decreased the electrode performance more rapidly than that of air shortage in gas shortage test. Honji et al reported that the rate of coarsening of Pt particle is rapid in open circuit potential and this is one of major causes on the performance degradation of electrode. The cathode performance has been studied by using acid absorption, acceleration and ac-impedance measurements as functions of the polytetrafluoroethylene (PTFE) contents and sintering temperatures of the electrode.

  1. Electrical Impedance Spectroscopy for Quality Assessment of Meat and Fish: A Review on Basic Principles, Measurement Methods, and Recent Advances

    Directory of Open Access Journals (Sweden)

    Xin Zhao

    2017-01-01

    Full Text Available Electrical impedance spectroscopy (EIS, as an effective analytical technique for electrochemical system, has shown a wide application for food quality and safety assessment recently. Individual differences of livestock cause high variation in quality of raw meat and fish and their commercialized products. Therefore, in order to obtain the definite quality information and ensure the quality of each product, a fast and on-line detection technology is demanded to be developed to monitor product processing. EIS has advantages of being fast, nondestructive, inexpensive, and easily implemented and shows potential to develop on-line detecting instrument to replace traditional methods to realize time, cost, skilled persons saving and further quality grading. This review outlines the fundamental theories and two common measurement methods of EIS applied to biological tissue, summarizes its application specifically for quality assessment of meat and fish, and discusses challenges and future trends of EIS technology applied for meat and fish quality assessment.

  2. Scenarios for measuring station-based impedances in a national transport model

    NARCIS (Netherlands)

    La Paix Puello, Lissy Cesarina; Geurs, Karst Teunis; van Weperen, Sander

    2015-01-01

    The measures of local and regional accessibility have been developed separately, resulting on a scarcely studied connection between these two. Accessibility evaluation of land-use and transport strategies can be much improved by linkages with more understandable, and local, accessibility measures

  3. Development of nuclear thermal hydraulic verification tests and evaluation technology - Development of a sensor for two-phase flow measurement using impedance method

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Moo Whan; Kang, Hie Chan; Kwon, Jung Tae; Huh, Deok; Yang, Hoon Cheul [Pohang University of Science and Technology, Pohang (Korea)

    2000-04-01

    Impedance method was carried out to design the electrode that can measure the void fraction of the bubbly flow in pool reservoir. To find out the optimum electrode shape, Styrofoam-Simulator tests were performed in a specially designed acrylic reservoir. Three kinds of electrodes were designed to compare the measuring characteristics of water-air flow. The resistance increased with the increase of the void fraction and the capacitance decreased with the increase of the void fraction. The resistance is a main parameter to express the nature of the water-air flow in impedance method. Almost of impedance values come out from the resistance. The degree of deviation from the mean-resistance values showed reasonable results. Electrode type-I expressed excellent results among the three electrode shapes. The sensor developed can simultaneously measure the void fraction and the water level. 7 refs., 51 figs., 4 tabs. (Author)

  4. Inter- and intraobserver agreement in 24-hour combined multiple intraluminal impedance and pH measurement in children.

    Science.gov (United States)

    Pilic, Denisa; Höfs, Carolin; Weitmann, Sandra; Nöh, Frank; Fröhlich, Thorsten; Skopnik, Heino; Köhler, Henrik; Wenzl, Tobias G; Schmidt-Choudhury, Anjona

    2011-09-01

    Assessment of intra- and interobserver agreement in multiple intraluminal impedance (MII) measurement between investigators from different institutions. Twenty-four 18- to 24-hour MII tracings were randomly chosen from 4 different institutions (6 per center). Software-aided automatic analysis was performed. Each result was validated by 2 independent investigators from the 4 different centers (4 investigator combinations). For intraobserver agreement, 6 measurements were analyzed twice by the same investigator. Agreement between investigators was calculated using the Cohen kappa coefficient. Interobserver agreement: 13 measurements showed a perfect agreement (kappa > 0.8); 9 had a substantial (kappa 0.61-0.8), 1 a moderate (kappa coefficient 0.41 to 0.6), and 1 a fair agreement (kappa coefficient 0.11-0.4). Median kappa value was 0.83. Intraobserver agreement: 5 tracings showed perfect and 1 showed a substantial agreement. The median kappa value was 0.88. Most measurements showed substantial to perfect intra- and interobserver agreement. Still, we found a few outliers presumably caused by poorer signal quality in some tracings rather than being observer dependent. An improvement of analysis results may be achieved by using a standard analysis protocol, a standardized method for judging tracing quality, better training options for method users, and more interaction between investigators from different institutions.

  5. Observing Tsunamis in the Ionosphere Using Ground Based GPS Measurements

    Science.gov (United States)

    Galvan, D. A.; Komjathy, A.; Song, Y. Tony; Stephens, P.; Hickey, M. P.; Foster, J.

    2011-01-01

    Ground-based Global Positioning System (GPS) measurements of ionospheric Total Electron Content (TEC) show variations consistent with atmospheric internal gravity waves caused by ocean tsunamis following recent seismic events, including the Tohoku tsunami of March 11, 2011. We observe fluctuations correlated in time, space, and wave properties with this tsunami in TEC estimates processed using JPL's Global Ionospheric Mapping Software. These TEC estimates were band-pass filtered to remove ionospheric TEC variations with periods outside the typical range of internal gravity waves caused by tsunamis. Observable variations in TEC appear correlated with the Tohoku tsunami near the epicenter, at Hawaii, and near the west coast of North America. Disturbance magnitudes are 1-10% of the background TEC value. Observations near the epicenter are compared to estimates of expected tsunami-driven TEC variations produced by Embry Riddle Aeronautical University's Spectral Full Wave Model, an atmosphere-ionosphere coupling model, and found to be in good agreement. The potential exists to apply these detection techniques to real-time GPS TEC data, providing estimates of tsunami speed and amplitude that may be useful for future early warning systems.

  6. Ground-based measurements of UV Index (UVI at Helwan

    Directory of Open Access Journals (Sweden)

    H. Farouk

    2012-12-01

    Full Text Available On October 2010 UV Index (UVI ground-based measurements were carried out by weather station at solar laboratory in NRIAG. The daily variation has maximum values in spring and summer days, while minimum values in autumn and winter days. The low level of UVI between 2.55 and 2.825 was found in December, January and February. The moderate level of UVI between 3.075 and 5.6 was found in March, October and November. The high level of UVI between 6.7 and 7.65 was found in April, May and September. The very high level of UVI between 8 and 8.6 was found in June, July and August. High level of radiation over 6 months per year including 3 months with a very high level UVI. According to the equation {UVI=a[SZA]b} the UVI increases with decreasing SZA by 82% on a daily scale and 88% on a monthly scale. Helwan exposure to a high level of radiation over 6 months per year including 3 months with a very high level UVI, so it is advisable not to direct exposure to the sun from 11 am to 2:00 pm.

  7. Design and evaluation of a handheld impedance plethysmograph for measuring heart rate variability

    DEFF Research Database (Denmark)

    Kristiansen, N. K.; Fleischer, J.; Jensen, M. S.;

    2005-01-01

    as the reference method. Agreement between the two methods in measuring heart rate and root mean square of successive differences in the heart beat interval (RMSSD) was analysed using correlation coefficients (Pearson's R-2), mean differences with 95% confidence intervals and 95% limits of agreement, and Bland-Altman...... plots. The correlation between the two methods was R-2 = 1.00 and R-2 = 0.99 when heart rate and RMSSD were measured, respectively. The Bland-Altman plots showed suitable agreement between the novel device and standard 10 s ECGs, which was substantiated by 95% limits of agreement of the difference...

  8. Centimeter Cosmo-Skymed Range Measurements for Monitoring Ground Displacements

    Science.gov (United States)

    Fratarcangeli, F.; Nascetti, A.; Capaldo, P.; Mazzoni, A.; Crespi, M.

    2016-06-01

    The SAR (Synthetic Aperture Radar) imagery are widely used in order to monitor displacements impacting the Earth surface and infrastructures. The main remote sensing technique to extract sub-centimeter information from SAR imagery is the Differential SAR Interferometry (DInSAR), based on the phase information only. However, it is well known that DInSAR technique may suffer for lack of coherence among the considered stack of images. New Earth observation SAR satellite sensors, as COSMO-SkyMed, TerraSAR-X, and the coming PAZ, can acquire imagery with high amplitude resolutions too, up to few decimeters. Thanks to this feature, and to the on board dual frequency GPS receivers, allowing orbits determination with an accuracy at few centimetres level, the it was proven by different groups that TerraSAR-X imagery offer the capability to achieve, in a global reference frame, 3D positioning accuracies in the decimeter range and even better just exploiting the slant-range measurements coming from the amplitude information, provided proper corrections of all the involved geophysical phenomena are carefully applied. The core of this work is to test this methodology on COSMO-SkyMed data acquired over the Corvara area (Bolzano - Northern Italy), where, currently, a landslide with relevant yearly displacements, up to decimeters, is monitored, using GPS survey and DInSAR technique. The leading idea is to measure the distance between the satellite and a well identifiable natural or artificial Persistent Scatterer (PS), taking in account the signal propagation delays through the troposphere and ionosphere and filtering out the known geophysical effects that induce periodic and secular ground displacements. The preliminary results here presented and discussed indicate that COSMO-SkyMed Himage imagery appear able to guarantee a displacements monitoring with an accuracy of few centimetres using only the amplitude data, provided few (at least one) stable PS's are available around the

  9. Estimation of Membrane Hydration Status for Standby Proton Exchange Membrane Fuel Cell Systems by Impedance Measurement: First Results on Stack Characterization

    DEFF Research Database (Denmark)

    Bidoggia, Benoit; Kær, Søren Knudsen

    Fuel cells have started replacing traditional lead-acid battery banks in backup systems. Although these systems are characterized by long periods of standby, they must be able to start at any instant in the shortest time. In the case of low temperature proton exchange membrane fuel cell systems......, a precise estimation of hydration status of the fuel cell during standby is important for a fast and safe startup. In this article, the measurement of the complex impedance of the fuel cell is suggested as a method to estimate the membrane hydration status. A 56-cell fuel cell stack has been symmetrically...... was applied, and the relationship between module of impedance and relative humidity was found. The results showed that measuring the impedance of a fuel cell during standby can be a viable way for estimating the hydration status of its membrane....

  10. Efficiency Analysis of Magnetic Field Measurement for MR Electrical Impedance Tomography (MREIT)

    DEFF Research Database (Denmark)

    Göksu, Cihan; Hanson, Lars G.; Ehses, Philipp;

    MREIT is an emerging method to measure the ohmic tissue conductivities, with several potential biomedical applications. Its sensitivity depends on the magnitude of the applied current, which is limited to 1-2 mA in the human brain [1, 2]. This renders in-vivo applications challenging. Here, we aim...

  11. Measurement of electrode-tissue interface impedance for improvement of a transcutaneous data transmission using human body as transmission medium.

    Science.gov (United States)

    Okamoto, Eiji; Kato, Yoshikuni; Kikuchi, Sakiko; Mitamura, Yoshinori

    2014-01-01

    The electrical property between an electrode and skin or tissue is one of the important issues for communication performance of the transcutaneous communication system (TCS) using a human body as a conductive medium.In this study, we used a simple method to measure interface resistance between the electrode and skin on the surface of the body. The electrode-electrode impedance was measured by a commercially available LCR meter with changes in the distance between two electrodes on an arm of a healthy male subject, and we obtained the tissue resistivity and electrode-skin interface resistance using the cross-sectional area of the arm.We also measured transmission gain of the TCS on the surface of the body, and we investigated the relationship between electrode-skin interface resistance and transmission gain. We examined four kinds of electrodes: a stainless steel electrode, a titanium electrode, an Ag-AgCl electrode and an Ag-AgCl paste electrode. The stainless steel electrode, which had lower electrode-skin resistance, had higher transmission gain.The results indicate that an electrode that has lower electrode-skin resistance will contribute to improvement of the performance of the TCS and that electrode-skin interface resistance is one of valuable evaluation parameters for selecting an optimum electrode for the TCS.

  12. Optically stimulated differential impedance spectroscopy

    Science.gov (United States)

    Maxey, Lonnie C; Parks, II, James E; Lewis, Sr., Samuel A; Partridge, Jr., William P

    2014-02-18

    Methods and apparatuses for evaluating a material are described. Embodiments typically involve use of an impedance measurement sensor to measure the impedance of a sample of the material under at least two different states of illumination. The states of illumination may include (a) substantially no optical stimulation, (b) substantial optical stimulation, (c) optical stimulation at a first wavelength of light, (d) optical stimulation at a second wavelength of light, (e) a first level of light intensity, and (f) a second level of light intensity. Typically a difference in impedance between the impedance of the sample at the two states of illumination is measured to determine a characteristic of the material.

  13. Estimation of membrane hydration status for active proton exchange membrane fuel cell systems by impedance measurement

    DEFF Research Database (Denmark)

    Török, Lajos; Sahlin, Simon Lennart; Kær, Søren Knudsen

    2016-01-01

    , the membrane of which PEMFCs are made of tends to dry out when not in use. This increases the time interval required to start the system up and could lead to the destruction of the fuel cell. In this article a start-up time measurement setup is presented, which is part of a larger project, the membrane......Fuel cells are getting growing interest in industrial areas like backup systems for telecom applications or power source for electric vehicles. Although these systems are characterized by long periods of inactivity, they must be able to start at any instant in the shortest time. However...... hydration status estimator for monitoring the humidity of a fuel cell stack during standby. The fuel cell has been placed in a climatic chamber, connected to hydrogen and the start-up time has been measured with different environmental conditions. Based on the previous results and the ones presented...

  14. Efficiency Analysis of Magnetic Field Measurement for MR Electrical Impedance Tomography (MREIT)

    DEFF Research Database (Denmark)

    Göksu, Cihan; Hanson, Lars G.; Ehses, Philipp

    MREIT is an emerging method to measure the ohmic tissue conductivities, with several potential biomedical applications. Its sensitivity depends on the magnitude of the applied current, which is limited to 1-2 mA in the human brain [1, 2]. This renders in-vivo applications challenging. Here, we aim...... to analyze and optimize the efficiency of two MREIT pulse sequences for in-vivo brain imaging....

  15. Evolution of an Atom Impeded by Measurement The Quantum Zeno Effect

    CERN Document Server

    Wunderlich, C; Toschek, P E; Wunderlich, Chr.; Balzer, Chr.

    2001-01-01

    A quantum system being observed evolves more slowly. This `'quantum Zeno effect'' is reviewed with respect to a previous attempt of demonstration, and to subsequent criticism of the significance of the findings. A recent experiment on an {\\it individual} cold trapped ion has been capable of revealing the micro-state of this quantum system, such that the effect of measurement is indeed discriminated from dephasing of the quantum state by either the meter or the environment.

  16. Ground and Airborne Methane Measurements using Optical Parametric Amplifiers

    Science.gov (United States)

    Riris, Haris; Numata, Kenji; Li, Steve; Wu, Stewart; Kawa, Stephan R.; Abshire, James; Dawsey, Martha; Ramanathan, Anand

    2012-01-01

    constant methane mixing ratio of 1.8 parts per million. The in-situ spectrometer did not show any significant deviations from the ambient concentrations. Further analysis using meteorological data from the Global Modeling and Assimilation Office (http://gmao.gsfc.nasa.gov/) to derive the theoretical optical depth also showed good agreement with the experimentally derived values. The OPA lidar system with slight modifications has also been used to measure CO2, water vapor, and CO in the near and mid-infrared spectral regions on the ground.

  17. 7 CFR 1755.406 - Shield or armor ground resistance measurements.

    Science.gov (United States)

    2010-01-01

    ... or armor ground resistance measurements shall be made on completed lengths of copper cable and wire... miles (km) of the cable or wire under test. (4)(i) The objective shield or armor ground resistance may... armor to ground resistance due to temperature. The variations can, however, be substantial for...

  18. Application of a Coaxial-Like Sensor for Impedance Spectroscopy Measurements of Selected Low-Conductivity Liquids

    Directory of Open Access Journals (Sweden)

    Wojciech Skierucha

    2013-09-01

    Full Text Available The paper presents a coaxial-like sensor operating in the 20 Hz–2 MHz frequency range used to determine the electrical properties of selected liquids of low electrical conductivity. Examined materials included low-concentrated aqueous solutions of potassium chloride, sodium chloride and trisodium citrate, which are common food additives. Impedance spectra of the measurement cell filled with particular liquids were obtained and analyzed using the electrical equivalent circuit approach. The values of physical quantities and parameters describing the equivalent circuit components, including a constant phase element, were calculated for each sample. The applied sensor was also calibrated for electrical conductivity measurements up to 8 mS/m. The constant phase element parameters differed among the studied solutions and concentrations. This may provide a basis for a detection method of small amounts of compounds, such as food additives in low-concentrated aqueous solutions. To demonstrate the potential of the presented method, samples of purchased mineral water and a flavored drink containing various additives were tested.

  19. Low impedance pH sensitive electrochemical devices that are potentially applicable to transcutaneous PCO2 measurements.

    Science.gov (United States)

    Yeung, H N; Beran, A V; Huxtable, R F

    1978-01-01

    Two cases of low impedance, non-glass membrane electrodes for pH measurement were evaluated: (I) Metal--metal oxide electrodes and (II) Reduction-oxidation electrodes. The fundamental cause of oxygen sensitivity of metal-metal oxide electrodes were examined and three approaches for its suppression were proposed. For the case of Sb--Sb2Ox electordes, oxygen sensitivity can be attenuated partially by cell loading, either directly across the reference electrode or indirectly across a third slave electrode. In a PO2 range of 8--54 kPa, more than 95% of the PO2 response can be suppressed by loading the cell emf to half of tis open-circuit value. The oxygen sensitivity also was observed to diminished by grinding the metal-metal oxide and pressing it under high pressure into a pellet electrode. Other metal-metal oxide electrodes that have promise in transcutaneous measurement are the Pd-PdO2 electrodes. The redox electrodes are typified by the Quinhydrone electrode. A membrane Quinhydrome electrode showed a sensitivity of 56 mV/Decade at 37 degree C and no oxygen sensitivity up to 50 kPa and a drift of 1 mV/h over a 24-h period. However, the stability deteriorated over a long-term period.

  20. Application of a coaxial-like sensor for impedance spectroscopy measurements of selected low-conductivity liquids.

    Science.gov (United States)

    Szypłowska, Agnieszka; Nakonieczna, Anna; Wilczek, Andrzej; Paszkowski, Bartosz; Solecki, Grzegorz; Skierucha, Wojciech

    2013-09-30

    The paper presents a coaxial-like sensor operating in the 20 Hz-2 MHz frequency range used to determine the electrical properties of selected liquids of low electrical conductivity. Examined materials included low-concentrated aqueous solutions of potassium chloride, sodium chloride and trisodium citrate, which are common food additives. Impedance spectra of the measurement cell filled with particular liquids were obtained and analyzed using the electrical equivalent circuit approach. The values of physical quantities and parameters describing the equivalent circuit components, including a constant phase element, were calculated for each sample. The applied sensor was also calibrated for electrical conductivity measurements up to 8 mS/m. The constant phase element parameters differed among the studied solutions and concentrations. This may provide a basis for a detection method of small amounts of compounds, such as food additives in low-concentrated aqueous solutions. To demonstrate the potential of the presented method, samples of purchased mineral water and a flavored drink containing various additives were tested.

  1. Surface Impedance Measurements of Single Crystal MgB2 Films for Radiofrequency Superconductivity Applications

    Energy Technology Data Exchange (ETDEWEB)

    Binping Xiao, Xin Zhao, Joshua Spradlin, Charles Reece, Michael Kelley, Teng Tan, Xi Xiaoxing

    2012-07-01

    We report microstructure analyses and superconducting radiofrequency (SRF) measurements of large scale epitaxial MgB{sub 2} films. MgB{sub 2} films on 5 cm dia. sapphire disks were fabricated by a Hybrid Physical Chemical Vapor Deposition (HPCVD) technique. The electron-beam backscattering diffraction (EBSD) results suggest that the film is a single crystal complying with a MgB{sub 2}(0001) {parallel} Al{sub 2}O{sub 3}(0001) epitaxial relationship. The SRF properties of different film thicknesses (200 nm and 350 nm) were evaluated under different temperatures and applied fields at 7.4 GHz. A surface resistance of 9 {+-} 2 {mu}{Omega} has been observed at 2.2 K.

  2. Bias and limits of agreement between hydrodensitometry, bioelectrical impedance and skinfold calipers measures of percentage body fat.

    Science.gov (United States)

    Williams, C A; Bale, P

    1998-02-01

    Previous research has often used correlations as a statistical method to show agreement; however, this is not a valid use of the statistic. The purpose of this study was to investigate the bias and limits of agreement for three methods of estimating percentage body fat for 117 male and 114 female university athletes: hydrodensitometry (HYD), bioelectrical impedance (BIA) and skinfold calipers (SKF). The mean (SD) percentage body fat for males as assessed by HYD, BIA and SKF methods, respectively, were 13.2 (3.3)%, 14.1, (3.3)% and 13.0 (3.2)%. Female body fat measurements were 22.5 (3.9)%, 23.7 (4.3)% and 23.8 (4.2)%, respectively. Pearson product moment correlations for male and female body fat percentages between the three methods were high, ranging from 0.81 to 0.86 (P < 0.05). However, compared to the criterion measure of body fat percentage (HYD), the magnitude of agreement BIA and SKF revealed a different pattern. The mean absolute difference between HYD and BIA measurements of body fat for males was -0.8 (2.0)% fat, and between HYD and SKF was it was 0.2 (1.7)% fat. The mean absolute difference for females between HYD and BIA was -1.2 (2.5)%; for HYD and SKF it was -1.4 (2.2)%. Compared to the HYD measures for males and females, the BIA and SKF measures were as much as a 3.8% underestimation and a 6.2% overestimation of body fat. This study provides evidence that the strength of a correlation does not indicate agreement between two methods. In future, reliability and validity studies should examine the absolute differences between two variables and calculate limits of agreement around which a practitioner can appreciate the precision of the methodologies.

  3. Reliability of Calf Bioelectrical Impedance Spectroscopy and Magnetic-Resonance-Imaging-Acquired Skeletal Muscle Hydration Measures in Healthy People

    Directory of Open Access Journals (Sweden)

    Anuradha Sawant

    2013-01-01

    Full Text Available Purpose. The purpose of this study was to investigate the test-retest reliability, relative variability, and agreement between calf bioelectrical impedance-spectroscopy (cBIS acquired extracellular fluid (ECF, intracellular fluid (ICF, total water and the ratio of ECF : ICF, magnetic-resonance-imaging (MRI acquired transverse relaxation times (T2, and apparent diffusion coefficient (ADC of calf muscles of the same segment in healthy individuals. Methods. Muscle hydration measures were collected in 32 healthy individuals on two occasions and analyzed by a single rater. On both occasions, MRI measures were collected from tibialis anterior (TA, medial (MG, and lateral gastrocnemius (LG and soleus muscles following the cBIS data acquired using XiTRON Hydra 4200 BIS device. The intraclass correlation coefficients (ICC2,1, coefficient of variation (CV, and agreement between MRI and cBIS data were also calculated. Results. ICC2,1 values for cBIS, T2, and ADC ranged from 0.56 to 0.92, 0.96 to 0.99, and 0.05 to 0.56, respectively. Relative variability between measures (CV ranged from 14.6 to 25.6% for the cBIS data and 4.2 to 10.0% for the MRI-acquired data. The ratio of ECF : ICF could significantly predict T2 of TA and soleus muscles. Conclusion. MRI-acquired measures of T2 had the highest test-retest reliability of muscle hydration with the least error and variation on repeated testing. Hence, T2 of a muscle is the most reliable and stable outcome measure for evaluating individual muscle hydration.

  4. Association of plasma adiponectin levels with cellular hydration state measured using bioelectrical impedance analysis in patients with COPD

    Directory of Open Access Journals (Sweden)

    Yoshikawa T

    2012-08-01

    Full Text Available Takahiro Yoshikawa,1 Hiroshi Kanazawa21Department of Sports Medicine, Osaka City University Graduate School of Medicine, 2Department of Respiratory Medicine, Osaka City University Graduate School of Medicine, Osaka, JapanBackground: It is widely recognized that chronic obstructive pulmonary disease (COPD includes a variety of extra pulmonary complications and comorbidities. Recently, adiponectin was shown to regulate cellular metabolism in humans. Cellular hydration state is affected by a variety of hormonal factors and regulates cellular metabolic state. Therefore, this study was designed to determine whether adiponectin is a possible factor involved in cellular hydration state in COPD.Methods: Thirty patients with COPD and 41 age-matched controls participated in the study. Plasma levels of total and high molecular weight (HMW adiponectin were measured and anthropometry and pulmonary function tests were conducted. Intracellular water (ICW, extracellular water (ECW, and ECW/ICW ratio, which are parameters of cellular hydration state, were measured using bioelectrical impedance analysis.Results: Higher levels of total and HMW adiponectin in plasma were found in patients with COPD compared with levels in controls. A significant inverse correlation was observed between body mass index and plasma levels of total and HMW adiponectin in the control group. However, this significant correlation was not observed in patients with COPD. The plasma levels of total and HMW adiponectin were also not significantly correlated with any pulmonary function parameters in patients with COPD. Regarding the state of cellular hydration, the plasma levels of total adiponectin were inversely correlated with the ECW/ICW ratio and positively with ICW values in patients with COPD. Moreover, closer correlations were found between these parameters and plasma HMW adiponectin levels.Conclusion: The results of the present study suggest a novel association of the plasma

  5. Estimation of Membrane Hydration Status for Standby Proton Exchange Membrane Fuel Cell Systems by Impedance Measurement: First Results on Stack Characterization

    DEFF Research Database (Denmark)

    Bidoggia, Benoit; Kær, Søren Knudsen

    Fuel cells have started replacing traditional lead-acid battery banks in backup systems. Although these systems are characterized by long periods of standby, they must be able to start at any instant in the shortest time. In the case of low temperature proton exchange membrane fuel cell systems...... was applied, and the relationship between module of impedance and relative humidity was found. The results showed that measuring the impedance of a fuel cell during standby can be a viable way for estimating the hydration status of its membrane....

  6. CENTIMETER COSMO-SKYMED RANGE MEASUREMENTS FOR MONITORING GROUND DISPLACEMENTS

    Directory of Open Access Journals (Sweden)

    F. Fratarcangeli

    2016-06-01

    Full Text Available The SAR (Synthetic Aperture Radar imagery are widely used in order to monitor displacements impacting the Earth surface and infrastructures. The main remote sensing technique to extract sub-centimeter information from SAR imagery is the Differential SAR Interferometry (DInSAR, based on the phase information only. However, it is well known that DInSAR technique may suffer for lack of coherence among the considered stack of images. New Earth observation SAR satellite sensors, as COSMO-SkyMed, TerraSAR-X, and the coming PAZ, can acquire imagery with high amplitude resolutions too, up to few decimeters. Thanks to this feature, and to the on board dual frequency GPS receivers, allowing orbits determination with an accuracy at few centimetres level, the it was proven by different groups that TerraSAR-X imagery offer the capability to achieve, in a global reference frame, 3D positioning accuracies in the decimeter range and even better just exploiting the slant-range measurements coming from the amplitude information, provided proper corrections of all the involved geophysical phenomena are carefully applied. The core of this work is to test this methodology on COSMO-SkyMed data acquired over the Corvara area (Bolzano – Northern Italy, where, currently, a landslide with relevant yearly displacements, up to decimeters, is monitored, using GPS survey and DInSAR technique. The leading idea is to measure the distance between the satellite and a well identifiable natural or artificial Persistent Scatterer (PS, taking in account the signal propagation delays through the troposphere and ionosphere and filtering out the known geophysical effects that induce periodic and secular ground displacements. The preliminary results here presented and discussed indicate that COSMO-SkyMed Himage imagery appear able to guarantee a displacements monitoring with an accuracy of few centimetres using only the amplitude data, provided few (at least one stable PS’s are

  7. Evidence for electronic and ionic limitations at the origin of the second voltage plateau in nickel electrodes, as deduced from impedance spectroscopy measurements

    Energy Technology Data Exchange (ETDEWEB)

    Barde, F.; Tarascon, J.M. [Laboratoire de Reactivite et de Chimie des Solides, Universite de Picardie Jules Verne, CNRS UMR 6007, F-80039 Amiens (France); Taberna, P.L. [CIRIMAT, CNRS UMR 5085, Universite Paul Sabatier, F-31062 Toulouse (France); Palacin, M.R. [Institut de Ciencia de Materials de Barcelona (CSIC), Campus UAB, E-08193 Bellaterra, Catalonia (Spain)

    2008-05-01

    The second plateau occurring during the reduction of the nickel oxyhydroxide electrode (NOE) was studied by impedance spectroscopy on a cell with a pasted electrode prepared from commercial undoped {beta}-Ni(OH){sub 2}. Measurements were performed at diverse states of reduction and a large variation of impedance upon the transition from the first to the second plateau was observed. This variation mainly takes place at low frequencies and is hence related to ionic diffusion. We observed that the impedance becomes more capacitive on the second plateau meaning that the proton diffusion is limited. These results would be consistent with the gradual formation of an insulating layer of nickel hydroxide at the interface between the NOE and the electrolyte upon reduction. Once this layer becomes compact the ionic diffusion would be hindered and forced to occur through this layer, which could explain the voltage drop observed. (author)

  8. Measurement of surface resistivity/conductivity of different organic thin films by a combination of optical shearography and electrochemical impedance spectroscopy

    Science.gov (United States)

    Habib, Khaled

    2013-11-01

    Shearography techniques were applied again to measure the surface resistivity/conductivity of different organic thin films on a metallic substrate. The coatings were ACE premium-grey enamel (spray coating), a yellow Acrylic lacquer, and a gold nail polish on a carbon steel substrate. The investigation was focused on determining the in-plane displacement of the coatings by shearography between 20 and 60 °C. Then, the alternating current (AC) impedance (resistance) of the same coated samples was determined by electrochemical impedance spectroscopy (EIS) in 3.0% NaCl solution at room temperature. As a result, the proportionality constant (resistivity or conductivity = 1/surface resistivity) between the determined AC impedance and the in-plane displacement was obtained. The obtained resistivity of all investigated coatings, 40:15 × 106-24:6 × 109Ωcm, was found in the insulator range.

  9. Longitudinal impedance of RHIC

    Energy Technology Data Exchange (ETDEWEB)

    Blaskiewicz, M. [Brookhaven National Lab. (BNL), Upton, NY (United States); Brennan, J. M. [Brookhaven National Lab. (BNL), Upton, NY (United States); Mernick, K. [Brookhaven National Lab. (BNL), Upton, NY (United States)

    2015-05-03

    The longitudinal impedance of the two RHIC rings has been measured using the effect of potential well distortion on longitudinal Schottky measurements. For the blue RHIC ring Im(Z/n) = 1.5±0.2Ω. For the yellow ring Im(Z/n) = 5.4±1Ω.

  10. Accurate monitoring of intravascular fluid volume: A novel application of intrathoracic impedance measures for the guidance of volume reduction therapy

    Directory of Open Access Journals (Sweden)

    Barbara A. Lara

    2015-09-01

    Conclusion: Impedance vectors derived from a multivector monitoring system reflect changes in intravascular plasma volume. Two of these vectors most closely track changes in plasma volume and may be used to more accurately guide and optimize volume reduction therapy.

  11. Sensing of damage and substrate stress in concrete using electro-mechanical impedance measurements of bonded PZT patches

    Science.gov (United States)

    Narayanan, Arun; Subramaniam, Kolluru V. L.

    2016-09-01

    The influence of stress and induced damage in concrete on the electro-mechanical (EM) impedance response of bonded PZT patches is evaluated for applied compressive loading. Full field displacements obtained from digital image correlation are used to evaluate the level of stress-induced damage in concrete. Stress in the substrate produces an imposed strain on the PZT. A change in the imposed strain produces a rightward frequency shift and an increase in the amplitude of the resonant peak in the EM conductance spectrum of the PZT. An increase in the substrate compliance produces a decrease in the resonant frequency and an increase in the amplitude of the resonant peak. Changes in the resonant peak in the conductance spectrum induced by increasing substrate stress are of a significant magnitude when compared with the changes induced by damage. In the early stages of damage associated with distributed microcracking, the counteracting influences of increasing level of damage and increasing stress on the resonant peak result in no shift in frequency for measurements under applied load. There is however an increase in the amplitude of the resonance peak. When the applied stress is removed, there is a net decrease in frequency resulting from damage in the form of distributed microcracks. Measures of changes in the resonant peak based on root mean square deviation (RMSD), do not show any observable change when measurements are performed under applied loading. There is a consistent increase in RMSD values and frequency shift with increasing damage when the applied stress is removed. The centroidal measure of the normalized frequency spectrum reflects changes in substrate stress. At higher applied stress levels, there is a nonlinear increase in damage, leading to localization and cracking. The influence of damage is dominant in this region and significant changes are obtained in the RMSD values in both loaded and unloaded conditions.

  12. Report of the SSC impedance workshop

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1985-10-28

    This workshop focused attention on the transverse, single-bunch instability and the detailed analysis of the broadband impedance which would drive it. Issues discussed included: (1) single bunch stability -- impact of impedance frequency shape, coupled-mode vs. fast blowup regimes, possible stopband structure; (2) numerical estimates of transverse impedance of inner bellows and sliding contact shielded bellows; (3) analytic estimates of pickup and kicker impedance contributions; and (4) feasibility studies of wire and beam measurements of component impedance.

  13. Regional ground deformation and its controlling measures in China

    Science.gov (United States)

    Zhou, Zhifang; Zhu, Haisheng; Huang, Yong

    2006-12-01

    With the development of construction of China Cities, there exist a lot of environmental geological problems involved in the geofracture, land subsidence, collapse, landslide, devolution, mudrock flow, floating sand, piping and soft ground deformation. Of big cities whose population is over one million in China, about 30 cities appears the land subsidence region. Other cities locate in the regions of collapse yellow earth or expand soil of strong swell-shrink charasteristic, soft ground and karst. In the paper, the cause and hazard of regionality ground deformation is summed up. The causes of regional land deformation caused by the natural geological effect and activities of human being are analyzed. According to the length of deformation course and endanger of society, economy and life, land deformation involves three types, that is, the delay, rapid and break land deformation. And the concrete countermeasure and method are provided.

  14. Negative transverse impedance

    Energy Technology Data Exchange (ETDEWEB)

    Chou, W.

    1989-06-12

    Recently, measurements in the SPS show that the coherent tune shift in the horizontal direction has positive values whereas that in the vertical direction has negative ones. Thus the existence of negative transverse impedance gets confirmed in a real machine. This stimulates us to start a new round of systematic studies on this interesting phenomenon. The results obtained from our computer simulations are presented in this note. Our simulations demonstrate that the negative transverse impedance may appear when the rotational symmetry embedded in a discontinuity is broken, and that the geometries that we have studies may be the source of the positive horizontal tune shift measured in the SPS.

  15. Study of the moisture content gradient in a cementitious material by measuring its impedance and gamma-densitometry

    Directory of Open Access Journals (Sweden)

    Guilbaud, J. P.

    2000-03-01

    Full Text Available The local water content in cementitious material depends on the equilibrium between its atmospheric environment and its bulk properties. So, the moisture profile in material can vary with time. The object of this study is to follow the change of this profile by measuring the electrical impedance of the material with pairs of small wires embedded at different depths. This method was applied to young cement paste specimens. The results obtained show that this method is quite satisfactory. The best frequency to be applied, is about 50 or 100 Hz. These results were compared with those obtained with gamma-densitometry.

    El agua contenida en los materiales en base cemento depende del equilibrio entre la atmósfera que le rodea y las propiedades de la matriz sólida. Por lo tanto el perfil de humedad en los materiales puede variar con el tiempo. La finalidad de este estudio es seguir los cambios en dicho perfil, a través de la medición de la impedancia eléctrica del material con varios pares de pequeños conductores situados a diferentes profundidadades. Este sistema se aplicó a diversas muestras de pasta de cemento Jóvenes. Los resultados obtenidos nos hacen ver que el método es satisfactorio, debiendo aplicarse a una frecuencia de 50 a 100 Hz. Dichos resultados se compararon con los obtenidos a través de la gammadensitometría.

  16. A Liquid Level Measurement Technique Outside a Sealed Metal Container Based on Ultrasonic Impedance and Echo Energy

    Directory of Open Access Journals (Sweden)

    Bin Zhang

    2017-01-01

    Full Text Available The proposed method for measuring the liquid level focuses on the ultrasonic impedance and echo energy inside a metal wall, to which the sensor is attached directly, not on ultrasonic waves that penetrate the gas–liquid medium of a container. Firstly, by analyzing the sound field distribution characteristics of the sensor in a metal wall, this paper proposes the concept of an "energy circle" and discusses how to calculate echo energy under three different states in detail. Meanwhile, an ultrasonic transmitting and receiving circuit is designed to convert the echo energy inside the energy circle into its equivalent electric power. Secondly, in order to find the two critical states of the energy circle in the process of liquid level detection, a program is designed to help with calculating two critical positions automatically. Finally, the proposed method is evaluated through a series of experiments, and the experimental results indicate that the proposed method is effective and accurate in calibration of the liquid level outside a sealed metal container.

  17. Relationship between the Initial Systolic Time Interval and RR-interval during an exercise stimulus measured with Impedance Cardiography

    Science.gov (United States)

    Hoekstra, Femke; Habers, Esther; Janssen, Thomas W. J.; Verdaasdonk, Rudolf M.; Meijer, Jan H.

    2010-04-01

    The Initial Systolic Time Interval (ISTI), obtained from the electrocardiogram and impedance cardiogram, is considered to be a measure for the time delay between the electrical and mechanical activity of the heart and reflects an active period of the heart cycle. The relationship between ISTI and the total heart cycle (RR-interval) was studied in three groups of young, healthy volunteers: low, moderately and highly trained subjects. The three groups were exposed to an exercise stimulus on a cycle ergometer with an increasing work load to increase the heart rate. ISTI was decreased with decreasing RR-interval. However, the relative proportion of ISTI, ISTI/RR, was found to increase with decreasing RR-interval. This relationship was found to be inversely proportional. The rate of this increase in ISTI/RR was significantly higher in highly trained subjects. Also, over the whole range of heart rates ISTI was longer in these subjects. It is concluded that ISTI can be used to evaluate cardiac performance during physical exercise non-invasively and in an extramural setting.

  18. Design and optimization of a noise reduction system for infrasonic measurements using elements with low acoustic impedance.

    Science.gov (United States)

    Alcoverro, Benoit; Le Pichon, Alexis

    2005-04-01

    The implementation of the infrasound network of the International Monitoring System (IMS) for the enforcement of the Comprehensive Nuclear-Test-Ban Treaty (CTBT) increases the effort in the design of suitable noise reducer systems. In this paper we present a new design consisting of low impedance elements. The dimensioning and the optimization of this discrete mechanical system are based on numerical simulations, including a complete electroacoustical modeling and a realistic wind-noise model. The frequency response and the noise reduction obtained for a given wind speed are compared to statistical noise measurements in the [0.02-4] Hz frequency band. The effects of the constructive parameters-the length of the pipes, inner diameters, summing volume, and number of air inlets-are investigated through a parametric study. The studied system consists of 32 air inlets distributed along an overall diameter of 16 m. Its frequency response is flat up to 4 Hz. For a 2 m/s wind speed, the maximal noise reduction obtained is 15 dB between 0.5 and 4 Hz. At lower frequencies, the noise reduction is improved by the use of a system of larger diameter. The main drawback is the high-frequency limitation introduced by acoustical resonances inside the pipes.

  19. A Liquid Level Measurement Technique Outside a Sealed Metal Container Based on Ultrasonic Impedance and Echo Energy.

    Science.gov (United States)

    Zhang, Bin; Wei, Yue-Juan; Liu, Wen-Yi; Zhang, Yan-Jun; Yao, Zong; Zhao, Li-Hui; Xiong, Ji-Jun

    2017-01-19

    The proposed method for measuring the liquid level focuses on the ultrasonic impedance and echo energy inside a metal wall, to which the sensor is attached directly, not on ultrasonic waves that penetrate the gas-liquid medium of a container. Firstly, by analyzing the sound field distribution characteristics of the sensor in a metal wall, this paper proposes the concept of an "energy circle" and discusses how to calculate echo energy under three different states in detail. Meanwhile, an ultrasonic transmitting and receiving circuit is designed to convert the echo energy inside the energy circle into its equivalent electric power. Secondly, in order to find the two critical states of the energy circle in the process of liquid level detection, a program is designed to help with calculating two critical positions automatically. Finally, the proposed method is evaluated through a series of experiments, and the experimental results indicate that the proposed method is effective and accurate in calibration of the liquid level outside a sealed metal container.

  20. Impedance modelling of pipes

    Science.gov (United States)

    Creasy, M. Austin

    2016-03-01

    Impedance models of pipes can be used to estimate resonant frequencies of standing waves and model acoustic pressure of closed and open ended pipes. Modelling a pipe with impedance methods allows additional variations to the pipe to be included in the overall model as a system. Therefore an actuator can be attached and used to drive the system and the impedance model is able to include the dynamics of the actuator. Exciting the pipe system with a chirp signal allows resonant frequencies to be measured in both the time and frequency domain. The measurements in the time domain are beneficial for introducing undergraduates to resonances without needing an understanding of fast Fourier transforms. This paper also discusses resonant frequencies in open ended pipes and how numerous texts incorrectly approximate the resonant frequencies for this specific pipe system.

  1. Finemet cavity impedance studies

    CERN Document Server

    Persichelli, S; Migliorati, M; Salvant, B

    2013-01-01

    The aim of the study is to evaluate the impedance of the Finemet kicker cavity to be installed in the PS straight section 02 during LS1, under realistic assumptions of bunch length. Time domain simulations with CST Particle Studio have been performed in order to get the impedance of the cavity and make a comparison with the longitudinal impedance measured for a single cell prototype. The study has been performed on simplified 3D geometries imported from a mechanical CATIA drawing, assuming that the simplications have small impact on the nal results. Simulations confirmed that the longitudinal impedance observed with measurements can be excited by bunches circulating in the PS. In the six-cells Finemet cavity, PS bunches circulating in the center can excite a longitudinal impedance, the real part of which has a maximum of 2 kOhm at 4 MHz. This mode does not seem to have any transverse component. All the eigenmodes of the cavity are strongly damped by the Finemet rings: we predict to have no issues regarding tr...

  2. Impedance of accelerator components

    Energy Technology Data Exchange (ETDEWEB)

    Corlett, J.N. [Center for Beam Physics, Lawrence Berkeley National Laboratory, I Cyclotron Road, Berkeley, California 94720 (United States)

    1997-01-01

    As demands for high luminosity and low emittance particle beams increase, an understanding of the electromagnetic interaction of these beams with their vacuum chamber environment becomes more important in order to maintain the quality of the beam. This interaction is described in terms of the wake field in time domain, and the beam impedance in frequency domain. These concepts are introduced, and related quantities such as the loss factor are presented. The broadband Q=1 resonator impedance model is discussed. Perturbation and coaxial wire methods of measurement of real components are reviewed. {copyright} {ital 1997 American Institute of Physics.}

  3. Implantable Impedance Plethysmography

    OpenAIRE

    2014-01-01

    We demonstrate by theory, as well as by ex vivo and in vivo measurements that impedance plethysmography, applied extravascularly directly on large arteries, is a viable method for monitoring various cardiovascular parameters, such as blood pressure, with high accuracy. The sensor is designed as an implant to monitor cardiac events and arteriosclerotic progression over the long term.

  4. Implantable Impedance Plethysmography

    Directory of Open Access Journals (Sweden)

    Michael Theodor

    2014-08-01

    Full Text Available We demonstrate by theory, as well as by ex vivo and in vivo measurements that impedance plethysmography, applied extravascularly directly on large arteries, is a viable method for monitoring various cardiovascular parameters, such as blood pressure, with high accuracy. The sensor is designed as an implant to monitor cardiac events and arteriosclerotic progression over the long term.

  5. Coupled field modeling of E/M impedance of piezoelectric wafer active sensor for cataphoretic coating thickness measurement

    Science.gov (United States)

    Kamas, T.; Tekkalmaz, M.

    2017-04-01

    The cataphoretic electro-coating is one of the most common methods that are used against corrosion as a primary coating layer. The cataphoretic electro-coating is commonly utilized technique especially in protecting of automobile components in automotive industry. This coating method has many advantages such as high corrosion resistance, ability of homogeneous and complete coating of components in any geometry, less pollution, and less risk of ignition. In this study, some specimens in the form of steel sheets coated by the cataphoretic electro-coating method are examined using electro-mechanical impedance spectroscopy (EMIS) method. One of the extensively employed sensor technologies has been permanently installed piezoelectric wafer active sensor (PWAS) for in situ continuous structural health monitoring (SHM). Using the transduction of ultrasonic elastic waves into voltage and vice versa, PWAS has been emerged as one of the major SHM sensing technologies. EMIS method has been utilized as a dynamic descriptor of PWAS and the structure on which it is bonded. EMIS of PWAS-structure couple is a high frequency local modal sensing technique by applying standing waves to indicate the response of the PWAS resonator by determining the resonance and anti-resonance frequencies. To simulate the actual EMIS measurements in the present work, two-dimensional and three-dimensional coupled field finite element models are created for both uncoated and coated steel plates in a commercial FEA software, ANSYS®. The EMIS values of the specimens in certain sizes and coated in different thickness are going to be simulated in broad-band of frequency spectra. The thickness of the coating layer and coating time are of paramount importance for the corrosion resistance. The coating layer thickness and the corresponding coating period will be optimized by analyses of the values obtained from the 2D and 3D EMIS simulations.

  6. Effect of HIPing on conductivity and impedance measurements of DyBi5Fe2Ti3O18 ceramics

    Indian Academy of Sciences (India)

    N V Prasad; G Prasad; Mahendra Kumar; S V Suryanarayana; T Bhimasankaram; G S Kumar

    2000-12-01

    X-ray diffraction, a.c. impedance and conductivity (a.c. and d.c.) have been used to characterize DyBi5Fe2Ti3O18. Samples were prepared by solid state double sintering method. A few samples were also subjected to hot isostatic pressing (HIP) at 800°C for 2 h at 100 MPa pressure. The data on XRD, impedance and conductivity of two sets of samples are compared to understand study of effect of HIPing on the properties of DyBi5Fe2Ti3O18.

  7. Measurement of electrical impedance of a Berea sandstone core during the displacement of saturated brine by oil and CO2 injections

    Science.gov (United States)

    Liu, Yu; Xue, Ziqiu; Park, Hyuck; Kiyama, Tamotsu; Zhang, Yi; Nishizawa, Osamu; Chae, Kwang-seok

    2015-12-01

    Complex electrical impedance measurements were performed on a brine-saturated Berea sandstone core while oil and CO2 were injected at different pressures and temperatures. The saturations of brine, oil, and CO2 in the core were simultaneously estimated using an X-ray computed tomography scanner. The formation factor of this Berea core and the resistivity indexes versus the brine saturations were calculated using Archie's law. The experimental results found different flow patterns of oil under different pressures and temperatures. Fingers were observed for the first experiment at 10 MPa and 40 °C. The fingers were restrained as the viscosity ratio of oil and water changed in the second (10 MPa and 25 °C) and third (5 MPa and 25 °C) experiments. The resistivity index showed an exponential increase with a decrease in brine saturation. The saturation exponent varied from 1.4 to 4.0 at different pressure and temperature conditions. During the oil injection procedure, the electrical impedance increased with oil saturation and was significantly affected by different oil distributions; therefore, the impedance varied whether the finger was remarkable or not, even if the oil saturation remained constant. During the CO2 injection steps, the impedance showed almost no change with CO2 saturation because the brine in the pores became immobile after the oil injection.

  8. Determination of the input impedance of RFID transponder antennas with novel measurement procedure using a modified on-wafer-prober

    Directory of Open Access Journals (Sweden)

    M. Camp

    2007-06-01

    Full Text Available This paper shows a new method to determine the input impedance of RFID transponder antennas with a combination of on-wafer-prober and network analyzer. It is shown that the results are in a good agreement with FEM simulations (HFSS for a large part of the examined antenna structures.

  9. [Variability in bioelectrical impedance assessment of body composition depending on measurement conditions: influence of fast and rest].

    Science.gov (United States)

    Cáceres, Diana Isabel; Sartor-Messagi, Monique; Rodríguez, Diego Agustín; Escalada, Ferran; Gea, Joaquim; Orozco-Levi, Mauricio; Marco, Ester

    2014-12-01

    Bioelectrical Impedance Assessment (BIA) is one of the main tools to measure body composition. BIA is recommended in fasting and after 60 minutes of rest; however, this cannot always be guaranteed in healthcare practice. To establish the reliability of the body composition parameters assessed with BIA under different physiological conditions: fast + rest, fast + no-rest and no-fast + no-rest in healthy volunteers. Transversal study including 25 healthy volunteers aged 18-34 (12 men, 13 women). A BIA was performed under three different conditions: 1) fast + 60 minute rest in cubito supino (gold standard), 2) fast + no rest and 3) no fast + no rest. The collected parameters were: lean mass and fat mass (Kg) and body water (in liters and as body weight percentage). The intraclass correlation coefficient (ICC) was applied for the assessment of concordance within the different measurements. Compared to the gold standard, the difference in lean mass means in the condition of fast + no-rest, was -0.15 (DE 1.44) in men and 0.98 (DE 1.36) in women; fat mass decreased in 0.06 (DE 1.55) in men and 0.82 (DE 1.5) in women; ICC ranged between 0.826-0.995 in all comparisons. In the condition of no-fast + no rest, lean mass decreased an average of 0.05 (DE 0.33) in men and it increased 0.62 (DE 0.46) in women; fat mass decreased 0.57 (DE 0.82) in men and 0.46 (DE 0.60) in women; ad ICC ranged between 0.942 and 0.999, except in body water in men, where it was 0.340. Although relevant, the differences observed in parameters from BIA when comparing the gold standard condition (fast + rest) with the other conditions (fast + no-rest and no-fast + no-rest) are of little magnitude. In clinical practice, the assessment of body composition allows to take decisions when planning treatment for patients with a poor physical condition. The reliability of the parameters acquired via BIA within different physiological conditions of fast and rest is excellent (CCI >0.75) in healthy adults aged 19

  10. Long term attenuation measurements on optical ground wires

    Energy Technology Data Exchange (ETDEWEB)

    Lamarche, L.; Gagnon, D.; Miron, M. [Hydro-Quebec, Varennes, Quebec1 (Canada)

    1996-11-01

    The attenuation stability of optical fibers integrated in optical ground wires (OPGW) cables over temperature and time is of paramount importance in the planning of long distance links. The authors report here a mean thermal attenuation dependence of 5.5{center_dot}10{sup {minus}5} dB/(km{center_dot}C) at 1,550 nm, on a 220 km span of dispersion shifted (DS) fibers of an installed OPGW cable. This optical link is installed in the James Bay region over a 735 kV power line where temperature varies from {minus}40 C to +30 C annually. The data sample presented covers 1.5 year starting December 1993. The data sample presented covers 1.5 year starting December 1993. During that period, the authors also observed a temporal evolution of the attenuation described by the empirical relation A = A{sub 0} (t{minus}t{sub 0}){sup 0.00394}.

  11. GPS Multipath Fade Measurements to Determine L-Band Ground Reflectivity Properties

    Science.gov (United States)

    Kavak, Adnan; Xu, Guang-Han; Vogel, Wolfhard J.

    1996-01-01

    In personal satellite communications, especially when the line-of-sight is clear, ground specular reflected signals along with direct signals are received by low gain, almost omni-directional subscriber antennas. A six-channel, C/A code processing, GPS receiver with an almost omni-directional patch antenna was used to take measurements over three types of ground to characterize 1.575 GHz specular ground reflections and ground dielectric properties. Fade measurements were taken over grass, asphalt, and lake water surfaces by placing the antenna in a vertical position at a fixed height from the ground. Electrical characteristics (conductivity and dielectric constant) of these surfaces (grass, asphalt, lake water) were obtained by matching computer simulations to the experimental results.

  12. EPA True NO2 ground site measurements – multiple sites, TCEQ ground site measurements of meteorological and air pollution parameters – multiple sites ,GeoTASO NO2 Vertical Column

    Data.gov (United States)

    U.S. Environmental Protection Agency — EPA True NO2 ground site measurements – multiple sites - http://www-air.larc.nasa.gov/cgi-bin/ArcView/discover-aq.tx-2013; TCEQ ground site measurements of...

  13. Ground-Based Lidar Measurements During the CALIPSO and Twilight Zone (CATZ) Campaign

    Science.gov (United States)

    Berkoff, Timothy; Qian, Li; Kleidman, Richard; Stewart, Sebastian; Welton, Ellsworth; Li, Zhu; Holbem, Brent

    2008-01-01

    The CALIPSO and Twilight Zone (CATZ) field campaign was carried out between June 26th and August 29th of 2007 in the multi-state Maryland-Virginia-Pennsylvania region of the U.S. to study aerosol properties and cloud-aerosol interactions during overpasses of the CALIPSO satellite. Field work was conducted on selected days when CALIPSO ground tracks occurred in the region. Ground-based measurements included data from multiple Cimel sunphotometers that were placed at intervals along a segment of the CALIPSO ground-track. These measurements provided sky radiance and AOD measurements to enable joints inversions and comparisons with CALIPSO retrievals. As part of this activity, four ground-based lidars provided backscatter measurements (at 523 nm) in the region. Lidars at University of Maryland Baltimore County (Catonsville, MD) and Goddard Space Flight Center (Greenbelt, MD) provided continuous data during the campaign, while two micro-pulse lidar (MPL) systems were temporarily stationed at various field locations directly on CALIPSO ground-tracks. As a result, thirteen on-track ground-based lidar observations were obtained from eight different locations in the region. In some cases, nighttime CALIPSO coincident measurements were also obtained. In most studies reported to date, ground-based lidar validation efforts for CALIPSO rely on systems that are at fixed locations some distance away from the satellite ground-track. The CATZ ground-based lidar data provide an opportunity to examine vertical structure properties of aerosols and clouds both on and off-track simultaneously during a CALIPSO overpass. A table of available ground-based lidar measurements during this campaign will be presented, along with example backscatter imagery for a number of coincident cases with CALIPSO. Results indicate that even for a ground-based measurements directly on-track, comparisons can still pose a challenge due to the differing spatio-temporal properties of the ground and satellite

  14. Soil moisture characterization of the Valencia anchor station. Ground, aircraft measurements and simulations

    DEFF Research Database (Denmark)

    Lopez-Baeza, E; Antolin, M C; Balling, Jan E.

    2009-01-01

    , soil type, lithology, geology, elevation, slope and vegetation cover conditions. Complementary to the ground measurements, flight operations were performed over this control area using the Helsinki University of Technology TKK Short Skyvan research aircraft which contained onboard a payload constituted...

  15. Towards a self-reporting coronary artery stent--measuring neointimal growth associated with in-stent restenosis using electrical impedance techniques.

    Science.gov (United States)

    Shedden, Laurie; Kennedy, Simon; Wadsworth, Roger; Connolly, Patricia

    2010-10-15

    Implantable medical devices have become the standard method for treating a variety of cardiovascular diseases (NICE, 2003, 2009), such as coronary artery disease, where coronary artery stents are the device of choice (Fischman et al., 1994; Babapulle et al., 2004). One post-operative problem with these devices is the long-term monitoring of the device-tissue interface, with respect to the complications that often arise from in-stent restenosis. This monitoring, where it is available, is currently performed using imaging techniques such as contrast angiography, IVUS, CT and MRI. In this study we propose an alternative method for the non-invasive monitoring of restenosis in coronary artery stents. This preliminary study uses impedance spectroscopy to measure the electrical impedance of cells and tissues associated with the neointimal growth that characterises in-stent restenosis in coronary artery stents. An in vitro organ culture model, using a stent implanted in a section of pig coronary artery, simulated tissue growth inside a stent. Impedance measurements were made regularly over a 28-day culture period. In a novel step, the stent itself was employed as an electrode. Differences in electrical impedance could be seen between control (stent alone) and artery-embedded stents in culture, which were associated with the presence of biological tissue. This method could potentially be developed to produce a stent that was capable of self-reporting in-stent restenosis. The advantages of such a device would be that monitoring could be non-invasively and easily carried out, allowing more routine follow-ups and the early identification and management of any device complications.

  16. Ground-based intercomparison of two isoprene measurement techniques

    Directory of Open Access Journals (Sweden)

    E. Leibrock

    2003-01-01

    Full Text Available An informal intercomparison of two isoprene (C5H8 measurement techniques was carried out during Fall of 1998 at a field site located approximately 3 km west of Boulder, Colorado, USA. A new chemical ionization mass spectrometric technique (CIMS was compared to a well-established gas chromatographic technique (GC. The CIMS technique utilized benzene cation chemistry to ionize isoprene. The isoprene levels measured by the CIMS were often larger than those obtained with the GC. The results indicate that the CIMS technique suffered from an anthropogenic interference associated with air masses from the Denver, CO metropolitan area as well as an additional interference occurring in clean conditions. However, the CIMS technique is also demonstrated to be sensitive and fast. Especially after introduction of a tandem mass spectrometric technique, it is therefore a candidate for isoprene measurements in remote environments near isoprene sources.

  17. Application of Impedance Matching Circuit in Filter Measure%阻抗匹配电路在滤波器测试中的应用

    Institute of Scientific and Technical Information of China (English)

    汶迎春

    2012-01-01

    To solve the problem of some type nonstandard impedance filter measure owing to sweep generator's aging, an impedance matching circuit is designed to measure filters by network analyzer. In this paper, measuring principles of sweep generator and network analyzer are introduced as well as their differences. The implement of net- work analyzer HP E5100B instead of sweep generator JW1252W in filter measure is given, and the principles of impedance matching circuit and its application in filter measure are expatiated. Experiments show that the use of the network analyzer can guarantee the consistency of numerical values to be measured. This method also has the advantages of easy operation and high precision and it can save labor and cost.%为解决扫频仪日趋老化带来的某型非标准阻抗滤波器测试问题,通过设计阻抗转换器实现了用网络分析仪对滤波器的测试。介绍了扫频仪与网络分析仪的测试原理和它们之间的区别,阐述了网络分析仪HPE5100B替代扫频仪JW1252W测试滤波器的实现方法,以及阻抗匹配电路的原理及其在滤波器测试中的应用。实验证明,用网络测试仪测试数值一致性好、操作简单、精度高、减少了工作量、降低了成本。

  18. Dust optical properties retrieved from ground-based polarimetric measurements.

    Science.gov (United States)

    Li, Zhengqiang; Goloub, Philippe; Blarel, Luc; Damiri, Bahaiddin; Podvin, Thierry; Jankowiak, Isabelle

    2007-03-20

    We have systematically processed one year of sunphotometer measurements (recorded at five AERONET/PHOTONS sites in Africa) in order to assess mineral dust optical properties with the use of a new polarimetry-based algorithm. We consider the Cimel CE318 polarized sunphotometer version to obtain single-scattering albedo, scattering phase matrix elements F(11) and F(12) for dust aerosols selected with Angström exponents ranging from -0.05 to 0.25. Retrieved F(11) and F(12) differ significantly from those of spherical particles. The degree of linear polarization -F(12)/F(11) for single scattering of atmospheric total column dust aerosols in the case of unpolarized incident light is systematically retrieved for the first time to our knowledge from sunphotometer measurements and shows consistency with previous laboratory characterizations of nonspherical particles.

  19. BOREAS RSS-11 Ground Network of Sunphotometer Measurements

    Science.gov (United States)

    Markham, Brian L.; Hall, Forrest G. (Editor); Nickerson, Jaime (Editor); Schafer, Joel; Smith, David E. (Technical Monitor)

    2000-01-01

    The BOREAS RSS-11 team operated a network of five automated (Cimel) and two hand-held (Miami) solar radiometers from 1994 to 1996 during the BOREAS field campaigns. The data provide aerosol optical depth measurements, size distribution, phase function, and column water vapor amounts over points in northern Saskatchewan and Manitoba, Canada. The data are useful for the correction of remotely sensed aircraft and satellite images. The data are provided in tabular ASCII files.

  20. Cellular impedance measurement as a new tool for poxvirus titration, antibody neutralization testing and evaluation of antiviral substances

    Energy Technology Data Exchange (ETDEWEB)

    Witkowski, Peter T. [Robert Koch-Institut, Zentrum fuer Biologische Sicherheit 1, Nordufer 20, 13353 Berlin (Germany); Charite Universitaetsmedizin, CCM, Institut fuer Virologie, Helmut Ruska Haus, Chariteplatz 1, 10117 Berlin (Germany); Schuenadel, Livia, E-mail: SchuenadelL@rki.de [FU-Berlin, Fachbereich Biologie, Chemie, Pharmazie, Takustrasse 3, 14195 Berlin (Germany); Robert Koch-Institut, Zentrum fuer Biologische Sicherheit 1, Nordufer 20, 13353 Berlin (Germany); Wiethaus, Julia; Bourquain, Daniel R.; Kurth, Andreas; Nitsche, Andreas [Robert Koch-Institut, Zentrum fuer Biologische Sicherheit 1, Nordufer 20, 13353 Berlin (Germany)

    2010-10-08

    Research highlights: {yields} Real-time data acquisition by RT-CES requires low operative effort. {yields} Time to result is reduced by using RT-CES instead of conventional methods. {yields} RT-CES enables quantification of virus titers in unknown samples. {yields} RT-CES is a useful tool for high-throughput characterization of antiviral agents. {yields} An RT-CES-based virus neutralization test was established. -- Abstract: Impedance-based biosensing known as real-time cell electronic sensing (RT-CES) belongs to an emerging technology for analyzing the status of cells in vitro. In the present study protocols were developed for an RT-CES-based system (xCELLigence{sup TM}, Roche Applied Science, ACEA Biosciences Inc.) to supplement conventional techniques in pox virology. First, proliferation of cells susceptible to orthopoxviruses was monitored. For virus titration cells were infected with vaccinia virus and cell status, represented by the dimensionless impedance-based cell index (CI), was monitored. A virus-dose dependent decrease in electrical impedance could be shown. Calculation of calibration curves at a suitable CI covering a dynamic range of 4 log enabled the quantification of virus titers in unknown samples. Similarly, antiviral effects could be determined as shown for anti-poxviral agents ST-246 and Cidofovir. Published values for the in vitro concentration that inhibited virus replication by 50% (IC{sub 50}) could be confirmed while cytotoxicity in effective concentrations was excluded in long-term incubation experiments. Finally, an RT-CES-based virus neutralization test was established. Various poxvirus-specific antibodies were examined for their neutralizing activity and a calculation mode for the neutralizing antibody titer was introduced. In summary, the presented RT-CES-based methods outmatch end-point assays by observing the cell population throughout the entire experiment while workload and time to result are reduced.

  1. Distance Protection Impedance Measurement for Inhomogeneous Multiple-Circuit 400/150 kV Transmission Lines with Shared Towers

    DEFF Research Database (Denmark)

    Bak, Claus Leth; Sigurbjörnsson, Ragnar; Bukh, Bjarne

    2016-01-01

    Combined transmission lines where different voltage levels shares same towers are used in transmission systems in order to save way of right. Faults between different voltage levels results in complex fault current distributions due to mutual couplings and the fact that the faulted phases no longer...... impedance for combined faults and thereby shed light on relay trips. This study uses actual fault records, analytical method and PSCAD simulation studies to analyse combined faults in an existing 400 and 150 kV transmission line owned by Danish TSO Energinet.dk. The results clearly show that an accurate...

  2. LRO Diviner Soil Composition Measurements - Lunar Sample Ground Truth

    Science.gov (United States)

    Allen, Carlton C.; Greenhagen, Benjamin T.; Paige, David A.

    2010-01-01

    The Diviner Lunar Radiometer Experiment on the Lunar Reconnaissance Orbiter [1,2] includes three thermal infrared channels spanning the wavelength ranges 7.55-8.05 microns 8.10-8.40 microns, and 8.38-8.68 microns. These "8 micron" bands were specifically selected to measure the "Christiansen feature". The wavelength location of this feature, referred to herein as CF, is particularly sensitive to silicate minerals including plagioclase, pyroxene, and olivine the major crystalline components of lunar rocks and soil. The general trend is that lower CF values are correlated with higher silica content and higher CF values are correlated with lower silica content. In a companion abstract, Greenhagen et al. [3] discuss the details of lunar mineral identification using Diviner data.

  3. The measurement of peripheral blood volume reactions to tilt test by the electrical impedance technique after exercise in athletes

    Science.gov (United States)

    Melnikov, A. A.; Popov, S. G.; Nikolaev, D. V.; Vikulov, A. D.

    2013-04-01

    We have investigated the distribution of peripheral blood volumes in different regions of the body in response to the tilt-test in endurance trained athletes after aerobic exercise. Distribution of peripheral blood volumes (ml/beat) simultaneously in six regions of the body (two legs, two hands, abdomen, neck and ECG) was assessed in response to the tilt-test using the impedance method (the impedance change rate (dZ/dT). Before and after exercise session cardiac stroke (CSV) and blood volumes in legs, arms and neck were higher in athletes both in lying and standing positions. Before exercise the increase of heart rate and the decrease of a neck blood volume in response to tilting was lower (p blood volumes was higher (pblood volumes were similar. Also, the neck blood volumes as percentage of CSV (%/CSV) did not change in the control but increased in athletes (p exercise (mean HR = 156±8 beat/min, duration 30 min) blood volumes in neck and arms in response to the tilting were reduced equally, but abdomen (pblood volumes (p blood flow (%/CSV) did not change in athletes but decreased in control (pexercise. The data demonstrate greater orthostatic tolerance in athletes both before and after exercise during fatigue which is due to effective distribution of blood flows aimed at maintaining cerebral blood flow.

  4. Designed microtremor array based actual measurement and analysis of strong ground motion at Palu city, Indonesia

    Science.gov (United States)

    Thein, Pyi Soe; Pramumijoyo, Subagyo; Brotopuspito, Kirbani Sri; Wilopo, Wahyu; Kiyono, Junji; Setianto, Agung; Putra, Rusnardi Rahmat

    2015-04-01

    In this study, we investigated the strong ground motion characteristics under Palu City, Indonesia. The shear wave velocity structures evaluated by eight microtremors measurement are the most applicable to determine the thickness of sediments and average shear wave velocity with Vs ≤ 300 m/s. Based on subsurface underground structure models identified, earthquake ground motion was estimated in the future Palu-Koro earthquake by using statistical green's function method. The seismic microzonation parameters were carried out by considering several significant controlling factors on ground response at January 23, 2005 earthquake.

  5. Designed microtremor array based actual measurement and analysis of strong ground motion at Palu city, Indonesia

    Energy Technology Data Exchange (ETDEWEB)

    Thein, Pyi Soe, E-mail: pyisoethein@yahoo.com [Geology Department, Yangon University (Myanmar); Pramumijoyo, Subagyo; Wilopo, Wahyu; Setianto, Agung [Geological Engineering Department, Gadjah Mada University (Indonesia); Brotopuspito, Kirbani Sri [Physics Department, Gadjah Mada University (Indonesia); Kiyono, Junji; Putra, Rusnardi Rahmat [Graduate School of Global Environmental Studies, Kyoto University (Japan)

    2015-04-24

    In this study, we investigated the strong ground motion characteristics under Palu City, Indonesia. The shear wave velocity structures evaluated by eight microtremors measurement are the most applicable to determine the thickness of sediments and average shear wave velocity with Vs ≤ 300 m/s. Based on subsurface underground structure models identified, earthquake ground motion was estimated in the future Palu-Koro earthquake by using statistical green’s function method. The seismic microzonation parameters were carried out by considering several significant controlling factors on ground response at January 23, 2005 earthquake.

  6. Development of a Time Domain Radio Frequency Plasma Impedance Probe For Measurement of Absolute Electron Density and Electron Neutral Collision Frequency

    Science.gov (United States)

    Spencer, E. A.

    2014-12-01

    We describe the development of a Time Domain Plasma Impedance Probe for the measurement of plasma properties in the ionosphere. It is being designed and developed to fly on cubesat platforms. The new instrument will be capable of making measurements of absolute electron density and electron neutral collision frequency at temporal and spatial resolutions not previously attained. A single measurement can be made in a time as short as 50 microseconds, which yields a spatial resolution of 0.35 meters for a satellite orbital velocity of 7 km/s. By averaging over 100 samples we expect an average spatial resolution of 35 meters. The method essentially consists of applying a small amplitude time limited voltage signal into a probe and measuring the resulting current response. The electron resonant frequencies of interest in the ionosphere are between are typically between 100 kHz and 20 MHz, which sets the required bandwidth. The new time domain method will present a significant improvement over the frequency domain method currently in use. The RF impedance probe has a distinct advantage over other methods used to measure plasma properties, in that it's measurements are not strongly affected by spacecraft charging effects that contaminate measurements made in the plasma environment. We will demonstrate the effectiveness of the instrument using data from sounding rocket missions, give details of the new instrument methodology, and suggest some possible areas of application of the method to measuring space plasmas. The difficulties associated with performing the measurements in a cubesat platform, and subsequently interpreting the measurements, will also be presented.

  7. IMPEDANCE CHARACTERISTICS OF POLYFURAN FILMS

    Institute of Scientific and Technical Information of China (English)

    Liang Li; Xiao-bo Wan; Gi Xue

    2002-01-01

    Electrochemical impedance spectroscopy (EIS) was first used for the characterization of polyfuran (PFu) films that had been formed electrochemically on an Au electrode. The polyfuran was measured in high oxidation state, intermediate oxidation state and reduction state, respectively. As the oxidation level is increased, the ionic conductivity of PFu/BF4-increases. And impedance studies on PFu show that the anion BF4- appears to be mobile with a high diffusion coefficient of approximately 10-8 cm2 @ s-1.

  8. Several issues in protective earth impedance measurement of medical electrical equipment%医用电气设备的保护接地阻抗测试

    Institute of Scientific and Technical Information of China (English)

    韩晓鹏; 梁振士; 任新颖; 魏红霞

    2015-01-01

    Several issues in protective earth impedance measurement of medical electrical equipment are addressed in this article. It is intended to help the test engineers to understand the requirements of the standard much better and perform the test correctly.%本文阐述了医用电气设备保护接地阻抗测试中需要注意的几个问题,旨在帮助测试人员更好地理解标准要求并进行正确的测试。

  9. RECIPROCITY CALIBRATION OF A SONAR TRANSDUCER FROM ELECTRICAL IMPEDANCE MEASUREMENTS IN WATER AND IN AIR : THE DELTA-Z RECIPROCITY CALIBRATION METHOD

    OpenAIRE

    S. Baker(Department of Physics and Astronomy, University College London, London, United Kingdom); Bedard, R.; Patton, M.; Wilson, O.

    1990-01-01

    A method is described by which the free-field, open-circuit voltage sensitivity of a reversible underwater acoustic transducer may be obtained from measurements of its input electrical impedance in water and in air. This method, which we have termed the Delta-Z reciprocity calibration method, is being developed for the in-service calibration of sonar transducers installed in domes which can be flooded and purged. The application of the Delta-Z method to the calibration of a single tonpilz-typ...

  10. A Feasible Approach for Improving Accuracy of Ground Deformation Measured by D-InSAR

    Institute of Scientific and Technical Information of China (English)

    CHANG Zhan-qiang; GONG Hui-li; ZHANG Jing-fa; GONG Li-xia

    2007-01-01

    D-InSAR is currently one of the most popular research tools in the field of Microwave Remote Sensing. It is unrivaled in its aspect of measuring ground deformation due to its advantages such as high resolution, continuous spatial-coverage and dynamics. However, there are still a few major problems to be solved urgently as a result of the intrinsic complexity of this technique. One of the problems deals with improving the accuracy of measured ground deformation. In this paper, various factors affecting the accuracy of ground deformation measured by D-InSAR are systematically analyzed and investigated by means of the law of measurement error propagation. At the same time, we prove that the ground deformation error not only depends on the errors of perpendicular baselines as well as the errors of the interferometric phase for topographic pair and differential pair, but also on the combination of the relationship of perpendicular baselines for topographic pairs and differential pairs. Furthermore, a feasible approach for improving the accuracy of measured ground deformation is proposed, which is of positive significance in the practical application of D-InSAR.

  11. Lab-on-chip microfluidic impedance measurement for laminar flow ratio sensing and differential conductivity difference detection

    Science.gov (United States)

    Kong, Tian Fook; Shen, Xinhui; Marcos, Yang, Chun

    2017-06-01

    We present a microfluidic impedance device for achieving both the flow ratio sensing and the conductivity difference detection between sample stream and reference buffer. By using a flow focusing configuration, with the core flow having a higher conductivity sample than the sheath flow streams, the conductance of the device varies linearly with the flow ratio, with R2 > 0.999. On the other hand, by using deionized (DI)-water sheath flow as a reference, we can detect the difference in conductivity between the buffer of core flow and sheath DI-water with a high detection sensitivity of up to 1 nM of sodium chloride solution. Our study provides a promising approach for on-chip flow mixing characterization and bacteria detection.

  12. Correlation study between ground motion intensity measure parameters and deformation demands for bilinear SDOF systems

    Institute of Scientific and Technical Information of China (English)

    2006-01-01

    The correlation between ground motion intensity measures (IM) and single-degree-of-freedom (SDOF) deformation demands is described in this study. Peak ground acceleration (APG), peak ground velocity (VPG), peak ground displacement (DPG), spectral acceleration at the first-mode period of vibration [As(T1)] and ratio of VPG to APG are used as IM parameters, and the correlation is characterized by correlation coefficients ρ. The numerical results obtained by nonlinear dynamic analyses have shown good correlation between As(T1) or VPG and deformation demands. Furthermore, the effect of As(T1) and VPG as IM on the dispersion of the mean value of deformation demands is also investigated for SDOF systems with three different periods T=0.3 s, 1.0 s, 3.0 s respectively.

  13. Results from a Novel Method for Corrosion Studies of Electroplated Lithium Metal Based on Measurements with an Impedance Scanning Electrochemical Quartz Crystal Microbalance

    Directory of Open Access Journals (Sweden)

    Martin Winter

    2013-07-01

    Full Text Available A new approach to study the chemical stability of electrodeposited lithium on a copper metal substrate via measurements with a fast impedance scanning electrochemical quartz crystal microbalance is presented. The corrosion of electrochemically deposited lithium was compared in two different electrolytes, based on lithium difluoro(oxalato borate (LiDFOB and lithium hexafluorophosphate, both salts being dissolved in solvent blends of ethylene carbonate and diethyl carbonate. For a better understanding of the corrosion mechanisms, scanning electron microscopy images of electrodeposited lithium were also consulted. The results of the EQCM experiments were supported by AC impedance measurements and clearly showed two different corrosion mechanisms caused by the different salts and the formed SEIs. The observed mass decrease of the quartz sensor of the LiDFOB-based electrolyte is not smooth, but rather composed of a series of abrupt mass fluctuations in contrast to that of the lithium hexafluorophosphate-based electrolyte. After each slow decrease of mass a rather fast increase of mass is observed several times. The slow mass decrease can be attributed to a consolidation process of the SEI or to the partial dissolution of the SEI leaving finally lithium metal unprotected so that a fast film formation sets in entailing the observed fast mass increases.

  14. Validation of Aura OMI by Aircraft and Ground-Based Measurements

    Science.gov (United States)

    McPeters, R. D.; Petropavlovskikh, I.; Kroon, M.

    2006-12-01

    Both aircraft-based and ground-based measurements have been used to validate ozone measurements by the OMI instrument on Aura. Three Aura Validation Experiment (AVE) flights have been conducted, in November 2004 and June 2005 with the NASA WB57, and in January/February 2005 with the NASA DC-8. On these flights, validation of OMI was primarily done using data from the CAFS (CCD Actinic Flux Spectroradiometer) instrument, which is used to measure total column ozone above the aircraft. These measurements are used to differentiate changes in stratospheric ozone from changes in total column ozone. Also, changes in ozone over high clouds measured by OMI were checked in a flight over tropical storm Arlene on a flight on June 11th. Ground-based measurements were made during the SAUNA campaign in Sodankyla, Finland, in March and April 2006. Both total column ozone and the ozone vertical distribution were validated.

  15. Airborne and ground based lidar measurements of the atmospheric pressure profile

    Science.gov (United States)

    Korb, C. Laurence; Schwemmer, Geary K.; Dombrowski, Mark; Weng, Chi Y.

    1989-01-01

    The first high accuracy remote measurements of the atmospheric pressure profile have been made. The measurements were made with a differential absorption lidar system that utilizes tunable alexandrite lasers. The absorption in the trough between two lines in the oxygen A-band near 760 nm was used for probing the atmosphere. Measurements of the two-dimensional structure of the pressure field were made in the troposphere from an aircraft looking down. Also, measurements of the one-dimensional structure were made from the ground looking up. Typical pressure accuracies for the aircraft measurements were 1.5-2 mbar with a 30-m vertical resolution and a 100-shot average (20 s), which corresponds to a 2-km horizontal resolution. Typical accuracies for the upward viewing ground based measurements were 2.0 mbar for a 30-m resolution and a 100-shot average.

  16. Estimating the ground-state probability of a quantum simulation with product-state measurements

    Directory of Open Access Journals (Sweden)

    Bryce eYoshimura

    2015-10-01

    Full Text Available .One of the goals in quantum simulation is to adiabatically generate the ground state of a complicated Hamiltonian by starting with the ground state of a simple Hamiltonian and slowly evolving the system to the complicated one. If the evolution is adiabatic and the initial and final ground states are connected due to having the same symmetry, then the simulation will be successful. But in most experiments, adiabatic simulation is not possible because it would take too long, and the system has some level of diabatic excitation. In this work, we quantify the extent of the diabatic excitation even if we do not know {it a priori} what the complicated ground state is. Since many quantum simulator platforms, like trapped ions, can measure the probabilities to be in a product state, we describe techniques that can employ these simple measurements to estimate the probability of being in the ground state of the system after the diabatic evolution. These techniques do not require one to know any properties about the Hamiltonian itself, nor to calculate its eigenstate properties. All the information is derived by analyzing the product-state measurements as functions of time.

  17. A Time Domain Impedance Probe For Ultra-Fast Measurements of Electron Parameters in the Ionosphere: Results From A NASA USIP Experiment

    Science.gov (United States)

    Clark, D. C.; Spencer, E. A.; Gollapalli, R.; Kerrigan, B.

    2016-12-01

    A plasma impedance probe is used to obtain plasma parameters in the ionosphere by measuring the magnitude, shape and location of resonances in the frequency spectrum when a probe structure is driven with RF excitation. We have designed and developed a new Time Domain Impedance Probe (TDIP) capable of making measurements of absolute electron density and electron neutral collision frequency at temporal and spatial resolutions not previously attained. A single measurement can be made in a time as short as 100 microseconds, which yields much higher spatial resolution than a frequency sweep method. This method essentially consists of applying a small amplitude time limited voltage signal into a probe and measuring the resulting current response. The frequency bandwidth of the voltage signal is selected in order that the electron plasma resonances are observable. A prototype of the new instrument was flown at 08:45 EST on March 1 2016 on a NASA Undergraduate Student Instrument Progam (USIP) sounding rocket launched out of Wallops Flight Facility (Flight time was around 20 minutes). Here we analyze the data from the sounding rocket experiment, using an adaptive system identification technique to compare the measured data with analytical formulas obtained from a theoretical consideration of the time domain response. The analytical formula is calibrated to a plasma fluid finite difference time domain (PFFDTD) numerical computation before using it to analyze the rocket data from 85 km to 170 km on both upleg and downleg. Our results show that the technique works as advertised, but several issues including payload charging and signal rectification remains to be resolved. A plasma impedance probe is used to obtain plasma parameters in the ionosphere by measuring the magnitude, shape and location of resonances in the frequency spectrum when a probe structure is driven with RF excitation. We have designed and developed a new Time Domain Impedance Probe (TDIP) capable of making

  18. A better method to define electrical chargeability from laboratory measurements of spectral impedance using a parallel Cole-Cole equivalent circuit

    Science.gov (United States)

    Enkin, R. J.

    2014-12-01

    Induced polarization (IP) is a successful electric method to identify drill targets for mineral exploration at the property scale. The Paleomagnetism and Petrophysics Laboratory at the Geological Survey of Canada makes petrophysical measurements on cylindrical rock samples, 2.5 cm diameter and 2.2 cm long. This small size has advantages, including allowing measurement of magnetic remanence with standard paleomagnetism equipment, but it is too small to allow a 4-contact electrical impedance measurement. The samples are impregnated with distilled water under vacuum and allowed 24 hours for solutes to dissolve off pore walls, in order to approximate original groundwater ionic conductivity. We use graphite electrodes on the flat surfaces and measure the complex impedance at 5 frequencies per decade from 1 MHz down to 25 mHz. Typical responses on a Cole-Cole plot (i.e., real vs. imaginary components displayed parametrically as a function of frequency) look like a two overlapping circular arcs followed by a constant-phase diffusive response at lowest frequencies. The impedance frequency response is fit with a circuit in which the rock is modelled as a set of parallel resistor and constant-phase-element pathways, connected in series through a modified constant-phase-element representing the low frequency sample-holder response. The program "ZarcFit", written in LabView, allows the operator to tune parameters of an equivalent but far more intuitive series circuit with a set of 13 sliders, and then perform a least-squares optimization. Time domain chargeability is defined by removing the effect of the sample holder, taking the Fourier transform to convert the frequency response to its time-domain equivalent and then integrating under the resulting voltage-decay curve. Time domain measurements using two-electrode sample holders are necessarily contaminated by the low-frequency response of ionic diffusion at the electrodes. Results are compiled in the Canadian Rock Physical

  19. Online Measurement of Real-Time Cytotoxic Responses Induced by Multi-Component Matrices, such as Natural Products, through Electric Cell-Substrate Impedance Sensing (ECIS

    Directory of Open Access Journals (Sweden)

    Adyary Fallarero

    2015-11-01

    Full Text Available Natural products are complex matrices of compounds that are prone to interfere with the label-dependent methods that are typically used for cytotoxicity screenings. Here, we developed a label-free Electric Cell-substrate Impedance Sensing (ECIS-based cytotoxicity assay that can be applied in the assessment of the cytotoxicity of natural extracts. The conditions to measure the impedance using ECIS were first optimized in mice immortalized hypothalamic neurons GT1-7 cells. The performance of four natural extracts when tested using three conventional cytotoxicity assays in GT1-7 cells, was studied. Betula pendula (silver birch tree was found to interfere with all of the cytotoxicity assays in which labels were applied. The silver birch extract was also proven to be cytotoxic and, thus, served as a proof-of-concept for the use of ECIS. The extract was fractionated and the ECIS method permitted the distinction of specific kinetic patterns of cytotoxicity on the fractions as well as the extract’s pure constituents. This study offers evidence that ECIS is an excellent tool for real-time monitoring of the cytotoxicity of complex extracts that are difficult to work with using conventional (label-based assays. Altogether, it offers a very suitable cytotoxicity-screening assay making the work with natural products less challenging within the drug discovery workflow.

  20. Online Measurement of Real-Time Cytotoxic Responses Induced by Multi-Component Matrices, such as Natural Products, through Electric Cell-Substrate Impedance Sensing (ECIS).

    Science.gov (United States)

    Fallarero, Adyary; Batista-González, Ana E; Hiltunen, Anna K; Liimatainen, Jaana; Karonen, Maarit; Vuorela, Pia M

    2015-11-12

    Natural products are complex matrices of compounds that are prone to interfere with the label-dependent methods that are typically used for cytotoxicity screenings. Here, we developed a label-free Electric Cell-substrate Impedance Sensing (ECIS)-based cytotoxicity assay that can be applied in the assessment of the cytotoxicity of natural extracts. The conditions to measure the impedance using ECIS were first optimized in mice immortalized hypothalamic neurons GT1-7 cells. The performance of four natural extracts when tested using three conventional cytotoxicity assays in GT1-7 cells, was studied. Betula pendula (silver birch tree) was found to interfere with all of the cytotoxicity assays in which labels were applied. The silver birch extract was also proven to be cytotoxic and, thus, served as a proof-of-concept for the use of ECIS. The extract was fractionated and the ECIS method permitted the distinction of specific kinetic patterns of cytotoxicity on the fractions as well as the extract's pure constituents. This study offers evidence that ECIS is an excellent tool for real-time monitoring of the cytotoxicity of complex extracts that are difficult to work with using conventional (label-based) assays. Altogether, it offers a very suitable cytotoxicity-screening assay making the work with natural products less challenging within the drug discovery workflow.

  1. Pulse Wave Velocity and Cardiac Output vs. Heart Rate in Patients with an Implanted Pacemaker Based on Electric Impedance Method Measurement

    Science.gov (United States)

    Soukup, Ladislav; Vondra, Vlastimil; Viščor, Ivo; Jurák, Pavel; Halámek, Josef

    2013-04-01

    The methods and device for estimation of cardiac output and measurement of pulse wave velocity simultaneously is presented here. The beat-to-beat cardiac output as well as pulse wave velocity measurement is based on application of electrical impedance method on the thorax and calf. The results are demonstrated in a study of 24 subjects. The dependence of pulse wave velocity and cardiac output on heart rate during rest in patients with an implanted pacemaker was evaluated. The heart rate was changed by pacemaker programming while neither exercise nor drugs were applied. The most important result is that the pulse wave velocity, cardiac output and blood pressure do not depend significantly on heart rate, while the stroke volume is reciprocal proportionally to the heart rate.

  2. A Theory-Grounded Measure of Adolescents' Response to a Media Literacy Intervention

    Science.gov (United States)

    Greene, Kathryn; Yanovitzky, Itzhak; Carpenter, Amanda; Banerjee, Smita C.; Magsamen-Conrad, Kate; Hecht, Michael L.; Elek, Elvira

    2015-01-01

    Media literacy interventions offer promising avenues for the prevention of risky health behaviors among children and adolescents, but current literature remains largely equivocal about their efficacy. The primary objective of this study was to develop and test theoretically-grounded measures of audiences' degree of engagement with the content of…

  3. Ground penetrating radar antenna measurements based on plane-wave expansions

    DEFF Research Database (Denmark)

    Lenler-Eriksen, Hans-Rudolph; Meincke, Peter

    2005-01-01

    The plane-wave transmitting spectrum of the system consisting of the ground penetrating radar (GPR) antenna and the air-soil interface is measured using a loop buried in the soil. The plane-wave spectrum is used to determine various parameters characterizing the radiation of the GPR antenna...

  4. A Theory-Grounded Measure of Adolescents' Response to a Media Literacy Intervention

    Science.gov (United States)

    Greene, Kathryn; Yanovitzky, Itzhak; Carpenter, Amanda; Banerjee, Smita C.; Magsamen-Conrad, Kate; Hecht, Michael L.; Elek, Elvira

    2015-01-01

    Media literacy interventions offer promising avenues for the prevention of risky health behaviors among children and adolescents, but current literature remains largely equivocal about their efficacy. The primary objective of this study was to develop and test theoretically-grounded measures of audiences' degree of engagement with the content of…

  5. Portable Ground Measurement & Control System%便携式地面测控系统

    Institute of Scientific and Technical Information of China (English)

    罗珊; 陈睿璟; 路引; 张哲聪

    2012-01-01

    为适应无人机地面测控技术的发展要求,设计一种便携式无人机地面控制系统.分析便携式无人机控制系统的基本技术和原理,着重探究便携式地面测控系统的工作原理,通过采用操纵杆和键盘指令由测控计算机完成向无人机靶机发送遥控指令.试验和测试结果表明,所设计的无人机靶机地面测控系统具有一定的可行性.%In order to meet the development requirement of UAV ground measurement & control technology, design a portable UVA ground control system. Analyze the basic technology and principle of portable UAV control system. Pay much attention to working principle of the UAV ground measurement and control system. Realize measurement and control computer sending remote command to UAV target drone by using joy stick and keyboard command. The test results show that the design of the UAV target drone ground measurement & control system is feasible.

  6. Measurement of Plane-Wave Spectra of Ground Penetrating Radar Antennas

    DEFF Research Database (Denmark)

    Lenler-Eriksen, Hans-Rudolph; Meincke, Peter

    2005-01-01

    The plane-wave transmitting spectrum of a ground penetrating radar (GPR) loop antenna close to the air-soil interface is measured by means of a probe buried in soil. Probe correction is implemented based upon knowledge about the complex permittivity of the soil and the current distribution...

  7. Alaskan permafrost groundwater storage changes derived from GRACE and ground measurements

    Science.gov (United States)

    Reginald R. Muskett; Vladimir E. Romanovsky

    2011-01-01

    The Arctic is in transition from climate-driven thawing of permafrost. We investigate satellite-derived water equivalent mass changes, snow water equivalent with in situ measurements of runoff and ground-survey derived geoid models from 1999 through 2009. The Alaskan Arctic coastal plain groundwater storage (including wetland bog, thaw pond and lake) is increasing by 1...

  8. Comparison of buried soil sensors, surface chambers and above ground measurements of carbon dioxide fluxes

    Science.gov (United States)

    Soil carbon dioxide (CO2) flux is an important component of the terrestrial carbon cycle. Accurate measurements of soil CO2 flux aids determinations of carbon budgets. In this study, we investigated soil CO2 fluxes with time and depth and above ground CO2 fluxes in a bare field. CO2 concentrations w...

  9. Derivation of the radiation budget at ground level from satellite measurements

    Science.gov (United States)

    Raschke, E.

    1982-01-01

    Determination of the Earth radiaton budget and progress in measurement of the budget components and in the treatment of imaging data from satellites are described. Methods for calculating the radiation budget in a general circulation model, radiative transfer characteristics of clouds, computation of solar radiation at ground level using meteorological data and development of a 10-channel radiometer are discussed.

  10. Measurement of Plane-Wave Spectra of Ground Penetrating Radar Antennas

    DEFF Research Database (Denmark)

    Lenler-Eriksen, Hans-Rudolph; Meincke, Peter

    2005-01-01

    The plane-wave transmitting spectrum of a ground penetrating radar (GPR) loop antenna close to the air-soil interface is measured by means of a probe buried in soil. Probe correction is implemented based upon knowledge about the complex permittivity of the soil and the current distribution...

  11. Body fat measurements in elite adolescent volleyball players: correlation between skinfold thickness, bioelectrical impedance analysis, air-displacement plethysmography, and body mass index percentiles.

    Science.gov (United States)

    Portal, Shawn; Rabinowitz, Jonathan; Adler-Portal, Dana; Burstein, Ruty Pilz; Lahav, Yair; Meckel, Yoav; Nemet, Dan; Eliakim, Alon

    2010-04-01

    Determination of body composition is an essential parameter in training athletes because low fat-muscle ratio might improve physical performance in many types of sports. Since training is often conducted in the field, it is important to determine whether simple field measurements of body composition assessment correlate with laboratory measurements. Examine the correlation of body fat content as measured using skinfold thicknesses (SF), air-displacement plethysmography (BOD POD), bioelectrical impedance analysis (BIA) and body mass index (BMI) age and gender adjusted percentiles. Body mass as measured by SF, BOD POD, BIA, and BMI percentiles were examined in 29 elite, national team level, male and female volleyball players (age range 13 to 18) at the beginning of the training season. Body fat percent measured by SF, BIA and BOD POD were highly positively correlated (r > 0.83). Measurements of body fat by SF, BIA and BOD POD were weakly correlated with BMI percentiles (r < 0.45). Results suggest that BMI percentile is not a good measure for body fat in adolescent elite male and female volleyball players. SF and measurements of body composition by BIA and BOD POD are essentially interchangeable.

  12. Inferring snow pack ripening and melt out from distributed ground surface temperature measurements

    Directory of Open Access Journals (Sweden)

    M.-O. Schmid

    2012-02-01

    Full Text Available The seasonal snow cover and its melting are heterogeneous both in space and time. Describing and modelling this variability are important because it affects divers phenomena such as runoff, ground temperatures or slope movements. This study investigates the derivation of melting characteristics based on spatial clusters of temperature measurements. Results are based on data from Switzerland where ground surface temperatures were measured with miniature loggers (iButtons at 40 locations, referred to as footprints. At each footprint, ten iButtons have been distributed randomly few cm below the ground surface over an area of 10 m × 10 m. Footprints span elevations of 2100–3300 m a.s.l. and slope angles of 0–55°, as well as diverse slope expositions and types of surface cover and ground material. Based on two years of temperature data, the basal ripening date and the melt-out date are determined for each iButton, aggregated to the footprint level and further analysed. The date of melt out could be derived for nearly all iButtons, the ripening date could be extracted for only approximately half of them because it requires ground freezing below the snow pack. The variability within a footprint is often considerable and one to three weeks difference between melting or ripening of the points in one footprint is not uncommon. The correlation of mean annual ground surface temperatures, ripening date and melt-out date is moderate, making them useful intuitive complementary measured for model evaluation.

  13. Measuring and monitoring to understand and reduce the fall-of-ground risk

    CSIR Research Space (South Africa)

    Vogt, D

    2013-10-01

    Full Text Available -1 ICSMRI 2013: 35th International Conference of Safety in Mines Research Institutes, Central Hall, Westminster, London, UK, 15-17 October 2013 Measuring and monitoring to understand and reduce the fall-of-ground risk Declan Vogt, CSIR Centre...-of-ground still constitute the single largest cause of fatalities. The data show that small falls of between 4 m2 and 10 m2, affecting single people, are the major cause of fatalities. The critical parameters that characterize the risk of rockfalls are: rock...

  14. SUPPORTING PROCEDURE AND FIELD MEASUREMENT IN THE SHAFT THROUGH GLIDING TECTONIC GROUND

    Institute of Scientific and Technical Information of China (English)

    XIAJianzhong; TENGNianbao

    1995-01-01

    The paper describes mechanical properties and deformation features of shaft adjoining rocks in gliding tectonic ground and presents the shaft-fupporting procedure of smooth-wall cushion blasting ,preliminary bolting and shotcreting and pouring reinforced concrete liner in one-time-whole-section in the basis of adjoining rock deformations measured dynamically in site ,Field measurements of the pressure exerted on shaft wall show that this supporting procedure has enough safety reserve to meet the safety repuirements in mining production.

  15. A flexible electrode array for muscle impedance measurements in the mouse hind limb: A tool to speed research in neuromuscular disease

    Science.gov (United States)

    Li, J.; Rutkove, S. B.

    2013-04-01

    Electrical impedance myography (EIM) is a bioelectrical impedance technique focused on the assessment of neuromuscular diseases using tetrapolar surface arrays. Recently, we have shown that reproducible and sensitive EIM measurements can be made on the gastrocnemius muscle of the mouse hind limb and that these are sensitive to disease alterations. A dedicated array would help speed data acquisition and provide additional sensitivity to disease-induced alterations. A flexible electrode array was developed with electrode sizes of 1mm × 1mm by Parlex, Inc. Tetrapolar electrode sets were arranged both parallel to (longitudinal) and orthogonally to (transverse) the major muscle fiber direction of the gastrocnemius muscle. Measurements were made with a dedicated EIM system. A total of 11 healthy animals and 7 animals with spinal muscular atrophy (a form of motor neuron disease) were evaluated after the fur was completely removed with a depilatory agent from the hind limb. Standard electrophysiologic testing (compound motor action potential amplitude and motor unit number estimation) was also performed. The flexible electrode array demonstrated high repeatability in both the longitudinal and transverse directions in the healthy and diseased animals (with intraclass correlation coefficients of 0.94 and 0.89, respectively, for phase angle measured transversely). In addition, differences between healthy and diseased animals were identifiable. For example, the 50 kHz transverse phase angle was higher in the healthy as compared to the SMA animals (16.8° ± 0.5 vs. 14.3° ± 0.7, respectively) at 21 weeks of age (p = 0.01). Differences in anisotropy were also identifiable. Correlations to several standard neurophysiologic parameters also appeared promising. This novel flexible tetrapolar electrode array can be used on the mouse hind limb and provides multidirectional data that can be used to assess muscle health. This technique has the potential of finding widespread use in

  16. Prediction of fat-free mass and percentage of body fat in neonates using bioelectrical impedance analysis and anthropometric measures: validation against the PEA POD.

    Science.gov (United States)

    Lingwood, Barbara E; Storm van Leeuwen, Anne-Martine; Carberry, Angela E; Fitzgerald, Erin C; Callaway, Leonie K; Colditz, Paul B; Ward, Leigh C

    2012-05-01

    Accurate assessment of neonatal body composition is essential to studies investigating neonatal nutrition or developmental origins of obesity. Bioelectrical impedance analysis or bioimpedance analysis is inexpensive, non-invasive and portable, and is widely used in adults for the assessment of body composition. There are currently no prediction algorithms using bioimpedance analysis in neonates that have been directly validated against measurements of fat-free mass (FFM). The aim of the study was to evaluate the use of bioimpedance analysis for the estimation of FFM and percentage of body fat over the first 4 months of life in healthy infants born at term, and to compare these with estimations based on anthropometric measurements (weight and length) and with skinfolds. The present study was an observational study in seventy-seven infants. Body fat content of infants was assessed at birth, 6 weeks, 3 and 4·5 months of age by air displacement plethysmography, using the PEA POD body composition system. Bioimpedance analysis was performed at the same time and the data were used to develop and test prediction equations for FFM. The combination of weight+sex+length predicted FFM, with a bias of < 100 g and limits of agreement of 6-13 %. Before 3 months of age, bioimpedance analysis did not improve the prediction of FFM or body fat. At 3 and 4·5 months, the inclusion of impedance in prediction algorithms resulted in small improvements in prediction of FFM, reducing the bias to < 50 g and limits of agreement to < 9 %. Skinfold measurements performed poorly at all ages.

  17. A comparative study of satellite estimation for solar insolation in Albania with ground measurements

    Energy Technology Data Exchange (ETDEWEB)

    Mitrushi, Driada, E-mail: driadamitrushi@yahoo.com; Berberi, Pëllumb, E-mail: pellumb.berberi@gmail.com; Muda, Valbona, E-mail: vmuda@hotmail.com; Buzra, Urim, E-mail: rimibuzra@yahoo.com [Department of Engineering Physics, Faculty of Engineering Mathematics and Engineering Physics, Polytechnic University of Tirana, Tirana (Albania); Bërdufi, Irma, E-mail: irmaberdufi@gmail.com [Institute of Applied Nuclear Physics, Tirana University, Street “Th. Filipeu”, Tirana (Albania); Topçiu, Daniela, E-mail: topciudaniela@yahoo.com [Department of Physics, Faculty of Natural Physics, “Aleksander Xhuvani” University, Elbasan (Albania)

    2016-03-25

    The main objective of this study is to compare data provided by Database of NASA with available ground data for regions covered by national meteorological net NASA estimates that their measurements of average daily solar radiation have a root-mean-square deviation RMSD error of 35 W/m{sup 2} (roughly 20% inaccuracy). Unfortunately valid data from meteorological stations for regions of interest are quite rare in Albania. In these cases, use of Solar Radiation Database of NASA would be a satisfactory solution for different case studies. Using a statistical method allows to determine most probable margins between to sources of data. Comparison of mean insulation data provided by NASA with ground data of mean insulation provided by meteorological stations show that ground data for mean insolation results, in all cases, to be underestimated compared with data provided by Database of NASA. Converting factor is 1.149.

  18. Ground based measurements of particulate emissions from supersonic transports. Concorde olympus engine

    Energy Technology Data Exchange (ETDEWEB)

    Whitefield, Ph.D.; Hagen, D.E. [Missouri Univ., Rolla, MO (United States). Cloud and Aerosol Sciences Lab.; Lilenfeld, H.V. [McDonnell Douglas Corp., St. Louis, MO (United States)

    1997-12-31

    The application of a mobile aerosol monitoring facility, the Mobile Aerosol Sampling System (MASS) is described to characterize engine aerosol emissions from the Rolls Royce Olympus Engine. The multi-configurational MASS has been employed in both ground and airborne field operations. It has been successfully flown on research aircrafts. In ground tests the MASS has participated in numerous jet engine related ground tests, and has been deployed to resolve aerosol generation problems in a high power chemical laser system. In all cases the measurements were made on samples taken from a harsh physical and chemical environment, with both high and low temperature and pressure, and in the presence of highly reactive gases. (R.P.) 9 refs.

  19. Protection Measures for Buildings Based on Coordinating Action Theory of Ground, Foundation and Structure

    Institute of Scientific and Technical Information of China (English)

    2006-01-01

    Based on the theory of coordinating action of building ground, foundation and structure, this paper presents a modified method for calculating additional stresses on buildings in mining areas by considering the joint effect of curvature deformation and horizontal deformation on buildings. It points out that for buildings over the coal pillar, it is advisable to soften the intermediate ground of buildings when they are affected by mining. For buildings over the goaf, it is preferable to soften the ground at both ends of buildings. In order to enhance the ability of a building to resist tensile deformation, the key measure is to reinforce the bottom foundation of the building. In addition, the concept of "angle of break of building" is proposed. It is because of this angle that the protecting coal pillar is left, which is a better solution than prevailing solutions The findings provide a more scientific basis for mining under buildings.

  20. Work flow of signal processing data of ground penetrating radar case of rigid pavement measurements

    Energy Technology Data Exchange (ETDEWEB)

    Handayani, Gunawan [The Earth Physics and Complex Systems Research Group (Jl. Ganesa 10 Bandung Indonesia) gunawanhandayani@gmail.com (Indonesia)

    2015-04-16

    The signal processing of Ground Penetrating Radar (GPR) requires a certain work flow to obtain good results. Even though the Ground Penetrating Radar data looks similar with seismic reflection data, but the GPR data has particular signatures that the seismic reflection data does not have. This is something to do with coupling between antennae and the ground surface. Because of this, the GPR data should be treated differently from the seismic signal data processing work flow. Even though most of the processing steps still follow the same work flow of seismic reflection data such as: filtering, predictive deconvolution etc. This paper presents the work flow of GPR processing data on rigid pavement measurements. The processing steps start from raw data, de-Wow process, remove DC and continue with the standard process to get rid of noises i.e. filtering process. Some radargram particular features of rigid pavement along with pile foundations are presented.

  1. Work flow of signal processing data of ground penetrating radar case of rigid pavement measurements

    Science.gov (United States)

    Handayani, Gunawan

    2015-04-01

    The signal processing of Ground Penetrating Radar (GPR) requires a certain work flow to obtain good results. Even though the Ground Penetrating Radar data looks similar with seismic reflection data, but the GPR data has particular signatures that the seismic reflection data does not have. This is something to do with coupling between antennae and the ground surface. Because of this, the GPR data should be treated differently from the seismic signal data processing work flow. Even though most of the processing steps still follow the same work flow of seismic reflection data such as: filtering, predictive deconvolution etc. This paper presents the work flow of GPR processing data on rigid pavement measurements. The processing steps start from raw data, de-Wow process, remove DC and continue with the standard process to get rid of noises i.e. filtering process. Some radargram particular features of rigid pavement along with pile foundations are presented.

  2. 天线阻抗的实时检测及自动校正系统设计%Real-time measurement and automatic correction for antenna impedance

    Institute of Scientific and Technical Information of China (English)

    张桂英; 戴宇杰; 张小兴; 吕英杰

    2013-01-01

    设计个低成本、全集成的天线阻抗自动校正系统以实现最大的功率传输及最好的链路性能.该系统包含2个独立的环路:第1个环路通过对并联LC调谐网络的控制实现对阻抗实部的实时检测与自动校正,而第2个环路通过对串联LC调谐网络的控制实现对阻抗虚部的实时检测与自动校正.在这2个环路中,调谐元件采用的是与标准CMOS 工艺兼容的MOS可变电容,以实现单片集成和连续调节.在第1个环路中,除了检测阻抗的实部信息外,还检测虚部的正负特性作为第2个控制准则来确保环路的稳定性.在不同的天线阻抗下,对该系统的性能进行仿真验证.研究结果表明:对于不同的天线阻抗,都能快速地校正到目标阻抗50Ω;调谐网络的插入损耗低于1.5 dB;与固定阻抗匹配系统相比,传输功率可高达3.7 dB.%A low cost and fully integrated automatic antenna impedance correction system was presented to realize the maximum power transfer and the best link quality, which consists of two independent loops. The first loop realizes real-time measurement and automatic correction of resistance by controlling a parallel LC tuning network, whereas the second loop achieves automatic reactance compensation by controlling a series LC tuning network. In both loops, MOS which are compatible with standard CMOS processing were applied as tunable elements to realize monolithic and sequential tuning. For the first loop, besides the intermediate resistance, the sign of the intermediate reactance was also detected as the second control criterion to enforce operation into a stable region. The performance of the proposed system was verified for different antenna impedances. The results show that all matched impedances are clustered around the target impedance 50 Ω quickly. The insertion loss of the tuning network is less than 1.5 dB. The power improvement can be up to 3.7 dB compared with the fixed impedance matching

  3. Compact rat-race ring coupler with meander high-impedance transmission line and port impedance matching

    Directory of Open Access Journals (Sweden)

    Jun He

    2015-08-01

    Full Text Available A novel compact rat-race ring coupler with meander high-impedance transmission line and port impedance matching is presented in this Letter. First, a ring coupler with high port impedance is designed using meander lines. Secondly, an impedance matching section is designed to match the high port impedance to ordinary 50 Ω. The proposed coupler effectively reduces occupied area to 16.8% of conventional one. The design is validated both by simulation and measurement.

  4. Impedance measurements in different alkaline solutions on an oxygen-evolving Lasub(0. 5)Srsub(0. 5)CoO/sub 3/ electrode

    Energy Technology Data Exchange (ETDEWEB)

    Willems, H.; Moers, M.; Broers, G.H.J.; Wit, J.H.W. de

    1985-10-25

    It was found that the oxygen evolution reaction on Lasub(0.5)Srsub(0.5)CoO/sub 3/ in strong alkaline solutions has a Tafel slope of proportional 60 mV/dec and a reaction order at constant overpotential with respect to the KOH activity of 0.6-0.8. From impedance measurements differential Tafel slopes were calculated and were found to be proportional 60 mV/dec at overpotentials >250 mV. Effective capacitances having a broad maximum at an overpotential of about 200 mV in all alkaline solutions were calculated. The effective capacitance increased with increasing KOH concentration. Furthermore, the material decomposed at the surface when exposed to strong oxygen evolution. From the results a modified Krasil'shchikov reaction path is analysed. (orig.).

  5. Comparative study of structural, optical and impedance measurements on V{sub 2}O{sub 5} and V-Ce mixed oxide thin films

    Energy Technology Data Exchange (ETDEWEB)

    Malini, D. Rachel [Department of Physics, The American College, Madurai-625 012 (India); Sanjeeviraja, C., E-mail: sanjeeviraja@rediffmail.com [Department of Physic, Alagappa Chettiar College of Engg. & Tech., Karaikudi-630 004 (India)

    2015-06-24

    Vanadium pentoxide (V{sub 2}O{sub 5}) and Vanadium-Cerium mixed oxide thin films at different molar ratios of V{sub 2}O{sub 5} and CeO{sub 2} have been deposited at 200 W rf power by rf planar magnetron sputtering in pure argon atmosphere. The structural and optical properties were studied by taking X-ray diffraction and transmittance and absorption spectra respectively. The amorphous thin films show an increase in transmittance and optical bandgap with increase in CeO{sub 2} content in as-prepared thin films. The impedance measurements for as-deposited thin films show an increase in electrical conductivity with increase in CeO{sub 2} material.

  6. Towards the measurement of the ground-state hyperfine splitting of antihydrogen

    Energy Technology Data Exchange (ETDEWEB)

    Juhasz, Bertalan, E-mail: bertalan.juhasz@oeaw.ac.at [Austrian Academy of Sciences, Stefan Meyer Institute for Subatomic Physics (Austria)

    2012-12-15

    The ASACUSA collaboration at the Antiproton Decelerator of CERN is planning to measure the ground-state hyperfine splitting of antihydrogen using an atomic beam line, which will consist of a superconducting cusp trap as a source of partially polarized antihydrogen atoms, a radiofrequency spin-flip cavity, a superconducting sextupole magnet as spin analyser, and an antihydrogen detector. This will be a measurement of the antiproton magnetic moment, and also a test of the CPT invariance. Monte Carlo simulations predict that the antihydrogen ground-state hyperfine splitting can be determined with a relative precision of better than {approx} 10{sup - 6}. The first preliminary measurements of the hyperfine transitions will start in 2011.

  7. Determining the location of buried plastic water pipes from measurements of ground surface vibration

    Science.gov (United States)

    Muggleton, J. M.; Brennan, M. J.; Gao, Y.

    2011-09-01

    ‘Mapping the Underworld' is a UK-based project, which aims to create a multi-sensor device that combines complementary technologies for remote buried utility service detection and location. One of the technologies to be incorporated in the device is low-frequency vibro-acoustics, and techniques for detecting buried infrastructure, in particular plastic water pipes, are being investigated. One of the proposed techniques involves excitation of the pipe at some known location with concurrent vibrational mapping of the ground surface in order to infer the location of the remainder of the pipe. In this paper, measurements made on a dedicated pipe rig are reported. Frequency response measurements relating vibrational velocity on the ground to the input excitation were acquired. Contour plots of the unwrapped phase revealed the location of the pipe to within 0.1-0.2 m. Magnitude contour plots revealed the excitation point and also the location of the pipe end. By examining the unwrapped phase gradients along a line above the pipe, it was possible to identify the wave-type within the pipe responsible for the ground surface vibration. Furthermore, changes in the ground surface phase speed computed using this method enabled the location of the end of the pipe to be confirmed.

  8. A novel wireless health monitor by using a wearable rubber glove with three-dimensional scanning elastic electrodes to measure acupuncture bio-potentials and impedances of a whole palm.

    Science.gov (United States)

    Lin, Jium-Ming; Lin, Cheng-Hung

    2015-01-01

    This paper proposes a novel wearable wireless-sensing technology on a glove to measure the bio-potentials and impedances of acupunctures on a whole palm in a non-invasive manner. Moreover, the device can transmit the information to a remote cloud server to learn at normal condition, and take measurement later for health condition analysis and monitoring. An example is given how to measure the acupuncture impedances and bio-potentials on a palm. One can see if certain acupuncture's impedance or bio-potential is not follow the Ohm's law or voltage divider rule along a meridian, then the health condition of the corresponding organ maybe with some problem. This discovery is not found in the previous literatures.

  9. Detecting plant metabolic responses induced by ground shock using hyperspectral remote sensing and physiological contact measurements

    Energy Technology Data Exchange (ETDEWEB)

    Pickles, W.L.; Cater, G.A.

    1996-12-03

    A series of field experiments were done to determine if ground shock could have induced physiological responses in plants and if the level of the response could be observed. The observation techniques were remote sensing techniques and direct contact physiological measurements developed by Carter for detecting pre-visual plant stress. The remote sensing technique was similar to that used by Pickles to detect what appeared to be ground shock induced plant stress above the 1993 Non Proliferation Experiment`s underground chemical explosion. The experiment was designed to provide direct plant physiological measurements and remote sensing ratio images and from the same plants at the same time. The simultaneous direct and remote sensing measurements were done to establish a ground truth dataset to compare to the results of the hyperspectral remote sensing measurements. In addition, the experiment was designed to include data on what was thought to be the most probable interfering effect, dehydration. The experimental design included investigating the relative magnitude of the shock induced stress effects compared to dehydration effects.

  10. Synergetic ground-based methods for remote measurements of ozone vertical profiles

    Science.gov (United States)

    Timofeyev, Yuriy; Kostsov, Vladimir; Virolainen, Yana

    2013-05-01

    The technique of combining ground-based measurements in infrared and microwave spectral regions in order to achieve higher accuracy of ozone profile retrieval in extensive altitude ranges is described and analyzed. The information content, errors, altitude ranges and vertical resolution of ozone profile retrieval have been studied on the basis of numerical simulation of synergetic experiments. Optimal conditions of measurements are defined and requirements to additional information are formulated. The first results on ozone vertical profile retrieval using groundbased measurements of FTIR-spectrometer and microwave radiometer are given.

  11. Cartesian impedance control of dexterous robot hand

    Institute of Scientific and Technical Information of China (English)

    JIANG Li; LIU Hong; CAI He-gao

    2005-01-01

    Presents a novel compliant motion control for a robot hand using the Cartesian impedance approach based on fingertip force measurements. The fingertip can accurately track desired motion in free space and appear as mechanical impedance in constrained space. In the position based impedance control strategy, any switching mode in contact transition phase is not needed. The impedance parameters can be adjusted in a certain range according to various tasks. In this paper, the analysis of the finger's kinematics and dynamics is given. Experimental results have shown the effectiveness of this control strategy.

  12. Comparison of MTI Water Temperatures with Ground Truth Measurements at Crater Lake, OR

    Energy Technology Data Exchange (ETDEWEB)

    Kurzeja, R.J.

    2002-12-09

    Water surface temperatures calculated with the Los Alamos National Laboratory Robust algorithm were compared with ground truth water temperature measurements near the Oregon State University buoy in Crater Lake, OR. Bulk water measurements at the OSU buoy were corrected for the skin temperature depression and temperature gradient in the top 10 cm of the water to find the water surface temperature for 18 MTI images for June 2000 to Feb 2002. The MTI robust temperatures were found to be biased by 0.1C, with an RMS error of 1.9C compared with the ground truth water surface temperatures. When corrected for the errors in the buoy temperatures the RMS was reduced to 1.3C. This RMS difference is greater than the 1C found at the Pacific Island of Nauru because of the greater variability in the lake temperature and the atmosphere at Crater Lake and the much smaller target area used in the comparison.

  13. Integrated ZnO nanoparticles on paper-based microfluidic: toward efficient analytical device for glucose detection based on impedance and FTIR measurement

    Science.gov (United States)

    Yuwono, Rio Akbar; Izdiharruddin, Mokhammad Fahmi; Wahyuono, Ruri Agung

    2016-11-01

    Microfluidic paper-based analytical devices decorated with ZnO nanospherical (nanoSPs) aggregates (ZnO-μPAD) for glucose detection have been fabricated. ZnO nanoSPs were prepared by wet chemical synthesis and integrated on the optimized geometry of ZnO-μPAD has 0.2 and 0.4 mm of channel width and length, respectively. Glucose detection measurements were based on electrochemical and infrared transmission measurements. The glucose concentrations were adjusted as 5, 6.5, and 9 mmol, i.e. typical glucose level for normal, pre-diabetes and diabetes, in a mixture of ringer lactate as simulated biological fluid and red blood cells. ZnO nanoSPs in this study possess an average aggregate size of 160 nm formed by clustered 18 nm crystallite size and ordered porous matrix as well as a surface area of 15 m2·g-1.The separation process of the glucose sample on ZnO-μPAD requires approximately 45 s. The glucose detection results show that both electrochemical-based and FTIR-based measurements perform a linear measurement system (R2 of 0.81 to 0.99) with a relatively high sensitivity. A linearly decreasing impedance spanning from 2.2 - 0.6 Ohm and linearly increasing ΔIR transmission spanning from 3 - 19% are obtained for glucose level ranging from 5 - 9 mmol.

  14. Test Operations Procedure (TOP) 02-2-546 Teleoperated Unmanned Ground Vehicle (UGV) Latency Measurements

    Science.gov (United States)

    2017-01-11

    A. Approved for public release; distribution is unlimited. 13. SUPPLEMENTARY NOTES Defense Technical Information Center (DTIC), AD No.: 14. ABSTRACT...discrete system components or measurements of latency in autonomous systems. 15. SUBJECT TERMS Unmanned Ground Vehicles, Basic Video Latency, End -to... End System Latency, Command-to-Action Latency 16. SECURITY CLASSIFICATION OF: 17. LIMITATION OF ABSTRACT SAR 18. NUMBER OF PAGES 23 19a

  15. Comparison of NO2 vertical profiles from satellite and ground based measurements over Antarctica

    OpenAIRE

    Kulkarni, Pavan; Bortoli, Daniele; Costa, Maria João; Silva, Ana Maria; Ravegnani, Fabrizio; Giovanelli, Giorgio

    2011-01-01

    The Intercomparison of nitrogen dioxide (NO2) vertical profiles, derived from the satellite based HALogen Occultation Experiment (HALOE) measurements and from the ground based UV-VIS spectrometer GASCOD (Gas Analyzer Spectrometer Correlating Optical Differences) observations at the Mario Zucchelli Station (MZS), in Antarctica, are done for the first time. It is shown here that both datasets are in good agreement showing the same features in terms of magnitude, profile structure, a...

  16. Transverse Impedance of LHC Collimators

    CERN Document Server

    Métral, E; Assmann, Ralph Wolfgang; Boccardi, A; Bracco, C; Bohl, T; Caspers, Friedhelm; Gasior, M; Jones, O R; Kasinski, K; Kroyer, T; Redaelli, S; Robert-Demolaize, R; Roncarolo, F; Rumolo, G; Salvant, B; Steinhagen, R; Weiler, T; Zimmermann, F

    2007-01-01

    The transverse impedance in the LHC is expected to be dominated by the numerous collimators, most of which are made of Fibre-Reinforced-Carbon to withstand the impacts of high intensity proton beams in case of failures, and which will be moved very close to the beam, with full gaps of few millimetres, in order to protect surrounding super-conducting equipments. We present an estimate of the transverse resistive-wall impedance of the LHC collimators, the total impedance in the LHC at injection and top energy, the induced coupled-bunch growth rates and tune shifts, and finally the result of the comparison of the theoretical predictions with measurements performed in 2004 and 2006 on a prototype collimator installed in the SPS.

  17. A six-beam method to measure turbulence statistics using ground-based wind lidars

    DEFF Research Database (Denmark)

    Sathe, Ameya; Mann, Jakob; Vasiljevic, Nikola

    2015-01-01

    A so-called six-beam method is proposed to measure atmospheric turbulence using a ground-based wind lidar. This method requires measurement of the radial velocity variances at five equally spaced azimuth angles on the base of a scanning cone and one measurement at the centre of the scanning circle...... lidar (WindScanner), and the derived turbulence statistics (using both methods) such as the u and v variances are compared with those obtained from a reference cup anemometer and a wind vane at 89m height under different atmospheric stabilities. The measurements show that in comparison to the reference...... cup anemometer, depending on the atmospheric stability and the wind field component, the six-beam method measures between 85 and 101% of the reference turbulence, whereas the VAD method measures between 66 and 87% of the reference turbulence....

  18. A six-beam method to measure turbulence statistics using ground-based wind lidars

    DEFF Research Database (Denmark)

    Sathe, Ameya; Mann, Jakob; Vasiljevic, Nikola

    2014-01-01

    A so-called six-beam method is proposed to measure atmospheric turbulence using a ground-based wind lidar. This method requires measurement of the radial velocity variances at five equally spaced azimuth angles on the base of a scanning cone and one measurement at the center of the scanning circle...... lidar (WindScanner), and the derived turbulence statistics (using both methods) such as the u and v variances are compared with those obtained from a reference cup anemometer and a wind vane at 89m height under different atmospheric stabilities. The measurements show that in comparison to the reference...... cup anemometer, depending on the atmospheric stability and the wind field component, the six-beam method measures between 85–101% of the reference turbulence, whereas the VAD method measures between 66–87% of the reference turbulence....

  19. Intercomparison of ground-based ozone and NO2 measurements during the MANTRA 2004 campaign

    Directory of Open Access Journals (Sweden)

    K. Strong

    2007-11-01

    Full Text Available The MANTRA (Middle Atmosphere Nitrogen TRend Assessment 2004 campaign took place in Vanscoy, Saskatchewan, Canada (52° N, 107° W from 3 August to 15 September, 2004. In support of the main balloon launch, a suite of five zenith-sky and direct-Sun-viewing UV-visible ground-based spectrometers was deployed, primarily measuring ozone and NO2 total columns. Three Fourier transform spectrometers (FTSs that were part of the balloon payload also performed ground-based measurements of several species, including ozone. Ground-based measurements of ozone and NO2 differential slant column densities from the zenith-viewing UV-visible instruments are presented herein. They are found to partially agree within NDACC (Network for the Detection of Atmospheric Composition Change standards for instruments certified for process studies and satellite validation. Vertical column densities of ozone from the zenith-sky UV-visible instruments, the FTSs, a Brewer spectrophotometer, and ozonesondes are compared, and found to agree within the combined error estimates of the instruments (15%. NO2 vertical column densities from two of the UV-visible instruments are compared, and are also found to agree within combined error (15%.

  20. Interference of heart and transcutaneous oxygen monitoring in the measurement of bioelectrical impedance analysis in preterm newborns

    Directory of Open Access Journals (Sweden)

    Viviane C. Comym

    Full Text Available Abstract Objective: To verify if the connection of electrodes for heart and transcutaneous oxygen monitoring interfere with the measurement of electrical bioimpedance in preterm newborns. Methods: This was a prospective, blinded, controlled, cross-sectional, crossover study that assessed and compared paired measures of resistance (R and reactance (Xc by BIA, obtained with and without monitoring wires attached to the preterm newborn. The measurements were performed in immediate sequence, after randomization to the presence or absence of electrodes. The sample size calculated was 114 measurements or tests with monitoring wires and 114 without monitoring wires, considering for a difference between the averages of 0.1 ohms, with an alpha error of 10% and beta error of 20%, with significance <0.05. Results: No differences were observed between the R (677.37 ± 196.07 vs. 677.46 ± 194.86 and Xc (31.15 ± 9.36 vs. 31.01 ± 9.56 values obtained with and without monitoring wires, respectively, with good correlation between them (R: 0.997 and Xc: 0.968. Conclusion: The presence of heart and/or transcutaneous oxygen monitoring wires connected to the preterm newborn did not affect the values of R or Xc measured by BIA, allowing them to be carried out in this population without risks.

  1. Time based measurement of the impedance of the skin-electrode interface for dry electrode ECG recording.

    Science.gov (United States)

    Dozio, Roberta; Baba, Adeshina; Assambo, Cedric; Burke, Martin J

    2007-01-01

    This paper reports the measurement of the properties of dry or pasteless conductive electrodes to be used for long-term recording of the human electrocardiogram (ECG). Knowledge of these properties is essential for the correct design of the input stage of associated recording amplifiers. Measurements were made on three commercially available conductive carbon based electrodes at pressures of 5 mmHg and 20 mmHg, located on the lower abdomen of the body on three subjects having different skin types. Parameter values were fitted to a two-time-constant based model of the electrode using data measured over a period of 10s. Values of resistance, ranging from 40kOmega to 1590kOmega and of capacitance ranging from 0.05 microF to 38 microF were obtained for the components, while the values of the time-constants varied from 0.07 s to 3.9s.

  2. Impedance Spectroscopy of Dielectrics and Electronic Conductors

    DEFF Research Database (Denmark)

    Bonanos, Nikolaos; Pissis, Polycarpos; Macdonald, J. Ross

    2013-01-01

    Impedance spectroscopy is used for the characterization of materials, such as electroceramics, solid and liquid electrochemical cells, dielectrics and also fully integrated devices, such as fuel cells. It consists of measuring the electrical impedance - or a closely related property, such as admi......Impedance spectroscopy is used for the characterization of materials, such as electroceramics, solid and liquid electrochemical cells, dielectrics and also fully integrated devices, such as fuel cells. It consists of measuring the electrical impedance - or a closely related property......, and procedures for the correction of measurement errors. The applications of impedance spectroscopy are illustrated with examples from electroceramics and polymer-based dielectric systems. The way in which the technique is applied to the two classes of materials is compared with reference to the different models...

  3. Experimental study of two-phase fluid flow in two different porosity types of sandstone by P-wave velocity and electrical Impedance measurement

    Science.gov (United States)

    Honda, H.; Mitani, Y.; Kitamura, K.; Ikemi, H.; Takaki, S.

    2015-12-01

    Carbon dioxide (CO2) capture and storage (CCS) is recently expected as the promising method to reduce greenhouse gas emissions. It is important to investigate CO2 behavior in the reservoir, to evaluate the safety and to account the stored CO2 volume. In this study, experimental investigation is conducted to discuss the relationships between injected fluid speed (Flow rate: FR) or capillary number (Ca) and non-wetting fluid flow by compressional wave velocity (Vp) and electrical impedance (Z). In the experiment, N2 and supercritical CO2 were injected into the two sandstones with different porosity (φ), Berea sandstone (φ: 18 %), and Ainoura sandstone (φ: 11.9 %). The dimension of the rock specimens is cored cylinder with a 35 mm diameter and 70 mm height. Experimental conditions are nearly same as the reservoir of deep underground (Confining pressure:15MPa, 40℃). Initial conditions of the specimen are brine (0.1wt%-KCl) saturated. Four piezo-electrical transducers (PZTs) are set on the each surface of the top, middle, lower of the specimen to monitor the CO2 bahavior by Vp. To measuring Z, we use for electrodes method with Ag-AgCl electrodes. Four electrodes are wounded around specimen on the both sides of PZTs. We measured the changes of these parameters with injecting N2, injected fluid speed (FR), the differential pore pressure (DP), N2 saturation (SN2), P-wave velocity (Vp) and electrical impedance (Z), respectively. We also estimated the Ca from measured FR. From these experimental results, there are no obvious Vp changes with increasing Ca, while Z measurement indicates clear and continuous increment. In regards to Vp, Vp reduced at the small FR (0.1 to 0.2 ml/min). As the Ca increases, Vp doesn't indicate large reduction. On the other hand, Z is more sensitive to change the fluid saturation than Vp. It is well-known that both of Vp and Z are the function of fluid saturation. Though, these experimental results are not consistent with previous studies. In

  4. Antenna characteristics and air-ground interface deembedding methods for stepped-frequency ground-penetrating radar measurements

    DEFF Research Database (Denmark)

    Karlsen, Brian; Larsen, Jan; Jakobsen, Kaj Bjarne;

    2000-01-01

    and phase information in the SF-GPR signal, is used to deembed the characteristics of the antenna. We propose a new air-to-ground interface deembedding technique based on Principal Component Analysis which enables enhancement of the SF-GPR signal from buried objects, e.g., anti-personal landmines...

  5. Accuracy of PARTwear Inertial Sensor and Optojump Optical Measurement System for Measuring Ground Contact Time During Running.

    Science.gov (United States)

    Ammann, Rahel; Taube, Wolfgang; Wyss, Thomas

    2016-07-01

    Ammann, R, Taube, W, and Wyss, T. Accuracy of PARTwear inertial sensor and Optojump optical measurement system for measuring ground contact time during running. J Strength Cond Res 30(7): 2057-2063, 2016-The aim of this study was to validate the detection of ground contact time (GCT) during running in 2 differently working systems: a small inertial measurement sensor, PARTwear (PW), worn on the shoe laces, and the optical measurement system, Optojump (OJ), placed on the track. Twelve well-trained subjects performed 12 runs each on an indoor track at speeds ranging from 3.0 to 9.0 m·s. GCT of one step per run (total 144) was simultaneously obtained by the PW, the OJ, and a high-speed video camera (HSC), whereby the latter served as reference system. The sampling rate was 1,000 Hz for all methods. Compared with the HSC, the PW and the OJ systems underestimated GCT by -1.3 ± 6.1% and -16.5 ± 6.7% (p-values ≤ 0.05), respectively. The intraclass correlation coefficients between PW and HSC and between OJ and HSC were 0.984 and 0.853 (p-values measurement systems.

  6. Measurement of Required Power with Human-Powered Aircraft in Take-off Ground Running

    Science.gov (United States)

    Yoshikawa, Toshiaki; Sakamoto, Shinsuke; Hori, Kotono; Kusumoto, Hiroshi; Yamamoto, Yasushi; Hattori, Takashi; Sata, Kouta

    In this paper, we propose the method for the measurement of required power and the adjustment of optimum gear ratio in take-off ground running. To get the values of required power and speed, we measured torque of the left side and the right side of pedals, RPM of pedals, and speed of the cockpit frame. In order to improve the take-off speed, some drums were applied, and the optimum gear ratio of the front drum to the rear drum was determined.

  7. Experimental Photoionization Cross-Section Measurements in the Ground and Metastable State Threshold Region of Se+

    CERN Document Server

    Sterling, N C; Bilodeau, R C; Kilcoyne, A L D; Red, E C; Phaneuf, R A; Aguilar, A

    2010-01-01

    Absolute photoionization cross-section measurements are reported for Se+ in the photon energy range 18.0-31.0 eV, which spans the ionization thresholds of the 4S_{3/2} ground state and the low-lying 2P_{3/2,1/2} and 2D_{5/2,3/2} metastable states. The measurements were performed using the Advanced Light Source synchrotron radiation facility. Strong photoexcitation-autoionization resonances due to 4p-->nd transitions are seen in the cross-section spectrum and identified with a quantum-defect analysis.

  8. Figure-ground organization in real and subjective contours: a new ambiguous figure, some novel measures of ambiguity, and apparent distance across regions of figure and ground.

    Science.gov (United States)

    Shank, M D; Walker, J T

    1989-08-01

    This study was designed to assess the effects of organization, luminance contrast, sector angle, and orientation on a new, highly ambiguous Cs-keyhole figure. Organization and contrast were the most important factors, and sector angle also influenced figure-ground relationships. There was no significant effect of orientation, nor was there any significant interaction between any of the factors. Several new measures of figure-ground organization were developed, such as ambiguity ratios based on reaction times and on ratings of the strength of perceived organizations, providing new quantitative measures of figure-ground relationships. Distances measured across figural regions appeared smaller than equal distances across the ground in the new reversible figure, and also in Rubin's classic vase-face figure presented in real and subjective contours. Inducing a perceptual set to see a particular organization in a reversible figure influenced the apparent distance across that organization. Several possible explanations of the observed effects are considered: (1) an instance of Emmert's law, based on the difference in apparent depth of figure and ground; (2) an aspect of the Müller-Lyer illusion; (3) a feature-detector model of contour attraction; (4) a natural set or predisposition to see a figure as smaller; and (5) framing effects. The first two explanations appear the most promising.

  9. Wire position system to consistently measure and record the location change of girders following ground changes

    Science.gov (United States)

    Choi, H. J.; Lee, S. B.; Lee, H. G.; Y Back, S.; Kim, S. H.; Kang, H. S.

    2017-07-01

    Several parts that comprise the large scientific device should be installed and operated at the accurate three-dimensional location coordinates (X, Y, and Z) where they should be subjected to survey and alignment. The location of the aligned parts should not be changed in order to ensure that the electron beam parameters (Energy 10 GeV, Charge 200 pC, and Bunch Length 60 fs, Emittance X/Y 0.481 μm/0.256 μm) of PAL-XFEL (X-ray Free Electron Laser of the Pohang Accelerator Laboratory) remain stable and can be operated without any problems. As time goes by, however, the ground goes through uplift and subsidence, which consequently deforms building floors. The deformation of the ground and buildings changes the location of several devices including magnets and RF accelerator tubes, which eventually leads to alignment errors (∆X, ∆Y, and ∆Z). Once alignment errors occur with regard to these parts, the electron beam deviates from its course and beam parameters change accordingly. PAL-XFEL has installed the Hydrostatic Leveling System (HLS) to measure and record the vertical change of buildings and ground consistently and systematically and the Wire Position System (WPS) to measure the two dimensional changes of girders. This paper is designed to introduce the operating principle and design concept of WPS and discuss the current situation regarding installation and operation.

  10. Wakefields and coupling impedances

    Energy Technology Data Exchange (ETDEWEB)

    Kurennoy, S. (Superconducting Super Collider Laboratory, 2550 Beckleymeade Ave., Dallas, Texas 75237 (United States))

    1995-02-01

    After a short introduction of the wake potentials and coupling impedances, a few new results in impedance calculations are discussed. The first example is a new analytical method for calculating impedances of axisymmetric structures in the low frequency range, below the cutoff frequency of the vacuum chamber. The second example demonstrates that even very small discontinuities on a smooth waveguide can result in appearance of trapped modes, with frequencies slightly below the waveguide cutoff frequency. The high-frequency (above the cutoff) behavior of the coupling impedance of many small discontinuities is discussed in the third example. [copyright] 1995 [ital American] [ital Institute] [ital of] [ital Physics

  11. Wakefields and coupling impedances

    Science.gov (United States)

    Kurennoy, Sergey

    1995-02-01

    After a short introduction of the wake potentials and coupling impedances, a few new results in impedance calculations are discussed. The first example is a new analytical method for calculating impedances of axisymmetric structures in the low frequency range, below the cutoff frequency of the vacuum chamber. The second example demonstrates that even very small discontinuities on a smooth waveguide can result in appearance of trapped modes, with frequencies slightly below the waveguide cutoff frequency. The high-frequency (above the cutoff) behavior of the coupling impedance of many small discontinuities is discussed in the third example.

  12. FSR: a field portable spectral reflectometer to measure ground from NIR to LWIR

    Science.gov (United States)

    Moreau, Louis; Bourque, Hugo; Ouellet, Réal; Prel, Florent; Roy, Claude; Vallieres, Christian; Thériault, Guillaume

    2011-11-01

    ABB Bomem has recently designed a field-deployable reflectometer. The Full Spectrum Reflectometer (FSR) measures the diffuse reflectance of surfaces in the 0.7 μm to 13.5 μm spectral range. The spectral resolution is adjustable from 32 to 4 cm-1. The instrument is portable, battery-operated and designed for field usage in a single, lightweight and ruggedized package. In its simplest mode, the instrument is automated and can be operated by non-specialist personnel with minimal training. The FSR has a laboratory mode to measure targets brought to the instrument in a sampling cup and a field mode with automated measurement sequence. To facilitate the measurement of various ground surfaces, the instrument is packaged in a three-point mount for easy target access and stability. One of the mount is the sampling port. The instrument has its own built-in NIR and LWIR infrared sources to illuminate the ground area to be measured. The instrument includes two built-in references for calibration: a Spectralon diffuser and an Infragold diffuser. The first units were commissioned to build a spectral database of surfaces in various conditions (humidity, temperature, texture, mixing, etc.) and in the presence of interfering chemicals (oils, solvents, etc.) but the instrument can also serve other purposes such as the identification of unknown materials.

  13. Ground-based SMART-COMMIT Measurements for Studying Aerosol and Cloud Properties

    Science.gov (United States)

    Tsay, Si-Chee

    2008-01-01

    From radiometric principles, it is expected that the retrieved properties of extensive aerosols and clouds from reflected/emitted measurements by satellite (and/or aircraft) should be consistent with those retrieved from transmitted/emitted radiance observed at the surface. Although space-borne remote sensing observations cover large spatial domain, they are often plagued by contamination of surface signatures. Thus, ground-based in-situ and remote-sensing measurements, where signals come directly from atmospheric constituents, the sun, and/or the Earth-atmosphere interactions, provide additional information content for comparisons that confirm quantitatively the usefulness of the integrated surface, aircraft, and satellite data sets. The development and deployment of SMARTCOMMIT (Surface-sensing Measurements for Atmospheric Radiative Transfer - Chemical, Optical & Microphysical Measurements of In-situ Troposphere) mobile facilities are aimed for the optimal utilization of collocated ground-based observations as constraints to yield higher fidelity satellite retrievals and to determine any sampling bias due to target conditions. To quantify the energetics of the surface-atmosphere system and the atmospheric processes, SMART-COMMIT instruments fall into three categories: flux radiometer, radiance sensor and in-situ probe. In this paper, we will demonstrate the capability of SMART-COMMIT in recent field campaigns (e.g., CRYSTAL-FACE, UAE 2, BASEASIA, NAMMA) that were designed and executed to study the compelling variability in temporal scale of both anthropogenic and natural aerosols (e.g., biomass-burning smoke, airborne dust) and cirrus clouds. We envision robust approaches in which well-collocated ground-based measurements and space-borne observations will greatly advance our knowledge of extensive aerosols and clouds.

  14. Impedance plethysmography of thoracic region: impedance cardiography.

    Directory of Open Access Journals (Sweden)

    Deshpande A

    1990-10-01

    Full Text Available Impedance plethysmograms were recorded from thoracic region in 254 normal subjects, 183 patients with coronary artery disease, 391 patients with valvular heart disease and 107 patients with congenital septal disorder. The data in 18 normal subjects and 55 patients showed that basal impedance decreases markedly during exercise in patients with ischaemic heart disease. Estimation of cardiac index by this technique in a group of 99 normal subjects has been observed to be more consistent than that of the stroke volume. Estimation of systolic time index from impedance plethysmograms in 34 normal subjects has been shown to be as reliable as that from electrocardiogram, phonocardiogram and carotid pulse tracing. Changes in the shape of plethysmographic waveform produced by valvular and congenital heart diseases are briefly described and the role of this technique in screening cardiac patients has been highlighted.

  15. Economic impact and effectiveness of radiation protection measures in aviation during a ground level enhancement

    Directory of Open Access Journals (Sweden)

    Matthiä Daniel

    2015-01-01

    Full Text Available In addition to the omnipresent irradiation from galactic cosmic rays (GCR and their secondary products, passengers and aircraft crew may be exposed to radiation from solar cosmic rays during ground level enhancements (GLE. In general, lowering the flight altitude and changing the flight route to lower latitudes are procedures applicable to immediately reduce the radiation exposure at aviation altitudes. In practice, however, taking such action necessarily leads to modifications in the flight plan and the consequential, additional fuel consumption constrains the mitigating measures. In this work we investigate in a case study of the ground level event of December 13th 2006 how potential mitigation procedures affect the total radiation exposure during a transatlantic flight from Seattle to Cologne taking into account constraints concerning fuel consumption and range.

  16. Measuring the electrical properties of soil using a calibrated ground-coupled GPR system

    Science.gov (United States)

    Oden, C.P.; Olhoeft, G.R.; Wright, D.L.; Powers, M.H.

    2008-01-01

    Traditional methods for estimating vadose zone soil properties using ground penetrating radar (GPR) include measuring travel time, fitting diffraction hyperbolae, and other methods exploiting geometry. Additional processing techniques for estimating soil properties are possible with properly calibrated GPR systems. Such calibration using ground-coupled antennas must account for the effects of the shallow soil on the antenna's response, because changing soil properties result in a changing antenna response. A prototype GPR system using ground-coupled antennas was calibrated using laboratory measurements and numerical simulations of the GPR components. Two methods for estimating subsurface properties that utilize the calibrated response were developed. First, a new nonlinear inversion algorithm to estimate shallow soil properties under ground-coupled antennas was evaluated. Tests with synthetic data showed that the inversion algorithm is well behaved across the allowed range of soil properties. A preliminary field test gave encouraging results, with estimated soil property uncertainties (????) of ??1.9 and ??4.4 mS/m for the relative dielectric permittivity and the electrical conductivity, respectively. Next, a deconvolution method for estimating the properties of subsurface reflectors with known shapes (e.g., pipes or planar interfaces) was developed. This method uses scattering matrices to account for the response of subsurface reflectors. The deconvolution method was evaluated for use with noisy data using synthetic data. Results indicate that the deconvolution method requires reflected waves with a signal/noise ratio of about 10:1 or greater. When applied to field data with a signal/noise ratio of 2:1, the method was able to estimate the reflection coefficient and relative permittivity, but the large uncertainty in this estimate precluded inversion for conductivity. ?? Soil Science Society of America.

  17. The in-line measurement of plant cell biomass using radio frequency impedance spectroscopy as a component of process analytical technology.

    Science.gov (United States)

    Holland, Tanja; Blessing, Daniel; Hellwig, Stephan; Sack, Markus

    2013-10-01

    Radio frequency impedance spectroscopy (RFIS) is a robust method for the determination of cell biomass during fermentation. RFIS allows non-invasive in-line monitoring of the passive electrical properties of cells in suspension and can distinguish between living and dead cells based on their distinct behavior in an applied radio frequency field. We used continuous in situ RFIS to monitor batch-cultivated plant suspension cell cultures in stirred-tank bioreactors and compared the in-line data to conventional off-line measurements. RFIS-based analysis was more rapid and more accurate than conventional biomass determination, and was sensitive to changes in cell viability. The higher resolution of the in-line measurement revealed subtle changes in cell growth which were not accessible using conventional methods. Thus, RFIS is well suited for correlating such changes with intracellular states and product accumulation, providing unique opportunities for employing systems biotechnology and process analytical technology approaches to increase product yield and quality. Copyright © 2013 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  18. Update of the SPS Impedance Model

    CERN Document Server

    Salvant, B; Zannini, C; Arduini, G; Berrig, O; Caspers, F; Grudiev, A; Métral, E; Rumolo, G; Shaposhnikova, E; Zotter, B; Migliorati, M; Spataro, B

    2010-01-01

    The beam coupling impedance of the CERN SPS is expected to be one of the limitations to an intensity upgrade of the LHC complex. In order to be able to reduce the SPS impedance, its main contributors need to be identified. An impedance model for the SPS has been gathered from theoretical calculations, electromagnetic simulations and bench measurements of single SPS elements. The current model accounts for the longitudinal and transverse impedance of the kickers, the horizontal and vertical electrostatic beam position monitors, the RF cavities and the 6.7 km beam pipe. In order to assess the validity of this model, macroparticle simulations of a bunch interacting with this updated SPS impedance model are compared to measurements performed with the SPS beam.

  19. Electrical Impedance Tomography Technology (EITT) Project

    Science.gov (United States)

    Oliva-Buisson, Yvette J.

    2014-01-01

    Development of a portable, lightweight device providing two-dimensional tomographic imaging of the human body using impedance mapping. This technology can be developed to evaluate health risks and provide appropriate medical care on the ISS, during space travel and on the ground.

  20. Microwave transmission-line impedance data

    CERN Document Server

    Gunston, M A R

    1996-01-01

    A compendium of data for computing the characteristic impedance of transmission lines based on physical dimensions. Covers both conventional structures and unusual geometries, including coaxial, eccentric and elliptic coaxial, twin-wire, wire-above-ground, microstrip and derivatives, stripline, slabline and trough line. Also details numerous configurations of coupled lines.