  1. Optimized ground-coupled heat pump system design for northern climate applications. [Including ground coil

    Energy Technology Data Exchange (ETDEWEB)

    Catan, M.A.; Baxter, V.D.

    1985-01-01

    This paper addresses the question of the performance of a ground coupled heat pump (GCHP) system with a water - source heat pump package designed expressly for such systems operating in a northern climate. The project objective was to minimize the life-cycle cost of a GCHP system by optimizing the design of both the heat pump package and the ground coil in concert. In order to achieve this objective, a number of modelling tools were developed or modified to analyze the heat pump's performance and cost and the ground coil's performance. The life-cycle cost of a GCHP system (water-source heat pump with a horizontal ground coil) for an 1800 ft/sup 2/ (167 m/sup 2/) house in Pittsburgh, PA, was minimized over a 7 year economic life. Simple payback for the optimized GCHP system, relative to conventional air-source heat pumps, was under 3 years. The water-source heat pump package resulting from this optimization is calculated to cost 21% more than its conventional counterpart with a heating coefficient of performance (COP) about 20% higher, and a cooling COP about 23% higher. In the GCHP system modeled, its annual energy savings are predicted to be about 11% compared to a system designed around the conventional heat pump while having about the same installation cost. The major conclusion of this study is - GCHP system performance improvement can be attained by improving the water-source heat pump package at less cost than by buying more ground coil. The following conclusions were drawn from the steady-state performance optimization results: (1) By adding about $100.00 to the manufacturer's cost off construction, both the heating and cooling COPs can be improved by 20% or more. (2) Cooling COP need not be sacrificed for the sake of heating performance and vice versa. 13 refs., 11 figs., 12 tabs.

  2. Theoretical and Experimental Study on Ground Coupled Heat Pump with Vertical Spiral Coil

    Institute of Scientific and Technical Information of China (English)

    李新国; 周倩; 赵军; 朱强; 胡璟

    2003-01-01

    The numerical simulation study on the temperature distribution of underground field for the ground coupled heat pump (GCHP) with vertical spiral coil was carried out by using finite element. The distribution and recovery of underground field temperature under different operation ratio and the optimal operation ratio were simulated. The performance parameters, i.e. inlet and outlet temperature of the ground spiral coil in heating and cooling modes were tested, the heat extracted or emitted by the heat pump to the ground was calculated, and the coefficients of performance (COP) of GCHP at heating and cooling modes were analyzed.

  3. Adjustable Induction-Heating Coil

    Science.gov (United States)

    Ellis, Rod; Bartolotta, Paul

    1990-01-01

    Improved design for induction-heating work coil facilitates optimization of heating in different metal specimens. Three segments adjusted independently to obtain desired distribution of temperature. Reduces time needed to achieve required temperature profiles.

  4. Optimization of a ground coupled heat pump

    Energy Technology Data Exchange (ETDEWEB)

    Baxter, V.D.; Catan, M.A.

    1984-01-01

    A cooperative analytical project has optimized a horizontal ground coil heat pump system for the Pittsburgh climate. This is the first step in the exploration of several advanced designs including various ground coil devices and advanced heat pump components. The project made use of new and existing design tools to simulate system performance and determine first cost. The system life cycle cost was minimized while constraining the system to meet the design day cooling load using a function minimizing program. Among the system parameters considered were: air-to-refrigerant frontal area, air-to-refrigerant fin pitch, air-to-refrigerant air flowrate, compressor displacement, liquid-to-refrigerant coil length, liquid-to-refrigerant coil diameter, ground coil fluid flowrate, ground coil length, and ground coil depth.

  5. Analytical and experimental analysis of tube coil heat exchanger

    Science.gov (United States)

    Smusz, R.

    2016-09-01

    The paper presents the analytical and experimental analysis of heat transfer for the finned tube coil heat exchanger immersed in thermal storage tank. The tank is equipped with three helical-shaped heating coils and cylindrical- shaped stratification device. Two coils, upper and lower, use the water as a heating medium. The third, double wall heat exchanger coil, located at the bottom head on the tank is filled by the refrigerant (freon). Calculations of thermal power of water coil were made. Correlations of heat transfer coefficients in curved tubes were applied. In order to verify the analytical calculations the experimental studies of heat transfer characteristic for coil heat exchanger were performed.

  6. Optimized ground coupled heat pump mechanical package

    Energy Technology Data Exchange (ETDEWEB)

    Catan, M.A.

    1987-01-01

    This project addresses the question of how well a ground coupled heat pump system could perform with a heat pump which was designed specifically for such systems operating in a northern climate. Conventionally, systems are designed around water source heat pumps which are not designed for ground coupled heat pump application. The objective of the project is to minimize the life cycle cost for a ground coupled system given the freedom to design the heat pump and the ground coil in concert. In order to achieve this objective a number of modeling tools were developed which will likely be of interest in their own right.

  7. Numerical simulation and validation on heat exchange performance of pile spiral coil ground heat exchanger%桩基螺旋型地埋管换热器换热性能的数值模拟与验证

    Institute of Scientific and Technical Information of China (English)

    杨卫波; 杨晶晶; 孔磊

    2016-01-01

    The new trends in energy savings and greenhouse gas reductions are expecting to explore the utilization of shallow geothermal energy. The most popular way to exploit shallow geothermal energy resources is the ground coupled heat pump (GCHP) system with using ground as a heat source. Because underground temperature is rather constant compared with ambient air temperature, the GCHP could achieve higher efficiency as well as more stable performance compared with traditional air source heat pumps. Thus the GCHP system becomes increasingly popular in commercial and institutional buildings. In general, a vertical borehole with ground heat exchanger (GHE) is used as the mainstream of GCHP system. However, the wide application of this type of GCHP technology has been limited by its higher initial cost and substantial land areas required to install the GHE. For this reason, the foundation piles of buildings have been used as part of GHE in recent years to reduce the cost of drilling borehole and save the required land area. This innovative idea of utilizing what are usually called “energy piles”, has led to notable progress in the field of GCHP systems. It has become particularly attractive because it lowers total cost and spatial requirements, and offers the higher renewable contribution. In this paper, a novel configuration of an energy pile with a spiral coil was proposed. In order to investigate the effects of various factors on heat exchange performance of the pile spiral coil GHE, a numerical model of the pile with a spiral coil was developed. Based on the numerical solution of the model, the effects of pile diameter, pile depth, spiral coil group number and soil type on the heat exchange rate and soil temperature distribution of the spiral pile GHE were analyzed. The results indicated that increasing foundation pile diameter can improve the thermal storage capacity and thus enhance heat exchange rate of pile. But increase in foundation pile diameter can also

  8. Study of the relation between evaluation of strain distribution on superconducting coil and mechanical heat generation

    Science.gov (United States)

    Seino, Hiroshi; Kurihara, Minoru; Herai, Toshiki; Suzuki, Eiji

    2002-10-01

    In the superconducting Maglev system, on-board superconducting magnets (SCMs) are vibrated at various frequencies according to the train speed by the electromagnetic disturbance which is caused when the train passes over ground coils. Then a mechanical loss is generated inside the inner vessel in the SCM. This phenomenon increases the heat load on the cryogenic equipment in the SCM. It has been surmised that the mechanical heat inside the inner vessel is generated by the frictional heat caused by the relative microscopic slips between fasteners and superconducting coil (SC coil). Nevertheless, heat generation mechanisms inside the inner vessel have not been studied sufficiently. In this study, we suggest a hypothesis that the frictional heat generated by the relative microscopic slips between fasteners and a SC coil will be indicated if the calculated strain distribution on the SC coil is evaluated. The results of this study supported this hypothesis.

  9. Optimized ground coupled heat pump mechanical package

    Energy Technology Data Exchange (ETDEWEB)

    Catan, M.A.

    1984-01-01

    The system which was optimized was a horizontal earth coil in a given house in the Pittsburgh area. The types of components used in the heat pump are essentially conventional. The method of this study is derived from one used to optimize an air-source heat pump for operation at standard steady state conditions. A computer model, created at Oak Ridge National Laboratory (ORNL), is used to predict heat pump performance for specified configuration and operating conditions. A predetermined set of design parameters is automatically altered by a constrained minimization program (a Numerical Algorithms Group library routine hereafter referred to as the optimizer) to find the combination for which the highest COP is predicted by the heat pump model. In the present study, the set of parameters to be varied include some pertaining to the ground coil as well as some pertaining to the heat pump. The optimizer, in this case, pursues a minimum life cycle cost which is calculated using the heat pump model, a ground coil model (called FTECM for Fast Transient Earth Coil model), and a parameterized cost model. The flow chart shows how the optimizer interacts with these programs to minimize life cycle cost.

  10. NUMERICAL INVESTIGATION FOR THE HEAT TRANSFER ENHANCEMENT IN HELICAL CONE COILS OVER ORDINARY HELICAL COILS

    Directory of Open Access Journals (Sweden)

    M. M. ABO ELAZM

    2013-02-01

    Full Text Available This numerical research is introducing the concept of helical cone coils and their enhanced heat transfer characteristics compared to the ordinary helical coils. Helical and spiral coils are known to have better heat and mass transfer than straight tubes, which is attributed to the generation of a vortex at the helical coil known as Dean Vortex. The Dean number which is a dimensionless number used to describe the Dean vortex is a function of Reynolds number and the square root of the curvature ratio, so varying the curvature ratio for the same coil would vary the Dean number. Two scenarios were adopted to study the effect of changing the taper angle (curvature ratio on the heat transfer characteristics of the coil; the commercial software FLUENT was used in the investigation. It was found that Nusselt number increased with increasing the taper angle. A MATLAB code was built based on empirical correlation of Manlapaz and Churchill for ordinary helical coils to calculate the Nusselt number at each coil turn, and then calculate the average Nusselt number for the entire coil turns, the CFD simulation results were found acceptable when compared with the MATLAB results.

  11. Heat load characteristics and new design using one-coil model superconducting magnets

    Science.gov (United States)

    Jizo, Yoshihiro; Akagi, Hidenari; Yamaguchi, Takashi; Terai, Motoaki; Shinobu, Masatoshi

    Superconducting magnets (SCM) for Maglev trains are vibrated by the electromagnetic force arising from the magnetic field of higher harmonics, which is due to the arrangement of the ground coils. The heat load within the liquid helium temperature region increases by the vibration of the magnets. This paper reports a heat load generation estimation mechanism due to the above-mentioned vibration, as well as effective measures of reducing heat load generation. In addition, we show how a one-coil type SCM can reduce the heat load generation in electromagnetic disturbance tests.

  12. Experimental Study of Free Convection in Coiled Tube Heat Exchanger

    Directory of Open Access Journals (Sweden)

    Harith Mohammed

    2013-05-01

    Full Text Available An experimental study has been conducted on steady-state natural convection heat transfer from helical coil tubes in vertical orientation. Water was used as a bath liquid without any mixing and cold water was used as a coolant fluid. A straight copper tube of 6 mm ID, 8 mm OD and 3 m length was bend to fabricate the helical coil. Four coils are used in this experiment has different curvature ratios and pitches. The data were correlated using tube diameter as the characteristic length. The results show that the overall heat transfer coefficient and Nusselt number increase when the flow rate of coolant and curvature ratio increase. The effect of coil pitch was investigated and the results show that when of the coil pitch (angle of inclination increases Nusselt number increase. A correlation was presented to calculate the outside average Nusselt number of coil.

  13. Temperature Profile Measurements During Heat Treatment of BSCCO 2212 Coils

    CERN Document Server

    ,

    2012-01-01

    The temperature profile of two different BSCCO 2212 coils has been analyzed. The profiles are obtained from thermocouples imbedded in the windings during the heat treatment that activates the 2212. The melting and freezing of the 2212 is clearly observed. A model that describes the data and can be used to guide the processing of new coils has been developed.

  14. Development of Ground Coils with Low Eddy Current Loss by Applying the Compression Molding Method after the Coil Winding

    Science.gov (United States)

    Suzuki, Masao; Aiba, Masayuki; Takahashi, Noriyuki; Ota, Satoru; Okada, Shigenori

    In a magnetically levitated transportation (MAGLEV) system, a huge number of ground coils will be required because they must be laid for the whole line. Therefore, stable performance and reduced cost are essential requirements for the ground coil development. On the other hand, because the magnetic field changes when the superconducting magnet passes by, an eddy current will be generated in the conductor of the ground coil and will result in energy loss. The loss not only increases the magnetic resistance for the train running but also brings an increase in the ground coil temperature. Therefore, the reduction of the eddy current loss is extremely important. This study examined ground coils in which both the eddy current loss and temperature increase were small. Furthermore, quantitative comparison for the eddy current loss of various magnet wire samples was performed by bench test. On the basis of the comparison, a round twisted wire having low eddy current loss was selected as an effective ground coil material. In addition, the ground coils were manufactured on trial. A favorable outlook to improve the size accuracy of the winding coil and uneven thickness of molded resin was obtained without reducing the insulation strength between the coil layers by applying a compression molding after winding.

  15. SIMULATION OF STEEL COIL HEAT TRANSFER IN HPH FURNACE

    Institute of Scientific and Technical Information of China (English)

    M.Y. Gu; G. Chen; M.C. Zhang; X.C. Dai

    2005-01-01

    The mathematical model has been established for the simulation of steel coil's heat transfer during annealing thermal process in HPH (high performance hydrogen) furnace. The equivalent radial thermal conductivity is adopted by statistical analysis regression approach through the combination of a large quantity of production data collected in practice and theoretical analyses. The effect of the number of coils on circulating flow gas is considered for calculating the convection heat transfer coefficient. The temperature within the coil is predicted with the developed model during the annealing cycle including heating process ard cooling process. The good consistency between the predicted results and the experimental data has demonstrated that the mathematical model established and the parameters identified by this paper are scientifically feasible and the effective method of calculation for coil equivalent radial heat transfer coefficient and circulating gas flow has been identified successfully, which largely enhances the operability and feasibility of the mathematic model. This model provides a theoretical basis and an effective means to conduct studies on the impact that foresaid factors may imposed on the steel coil's temperature field, to analyze the stress within coils, to realize online control and optimal production and to increase facility output by increasing heating and cooling rates of coils without producing higher thermal stress.

  16. Improving heat transfer in stirred tanks cooled by helical coils

    Directory of Open Access Journals (Sweden)

    S.M.C.P. Pedrosa

    2003-06-01

    Full Text Available Stirred Tank Reactors are extensively used in chemical industries. When they are used for highly exothermic reactions, jackets or coils are employed for heat removal. Internal coils can be either helical or axial and they considerably affect the flow inside the reactor because they impose an additional resistance to flow circulation. The aim of this work is to show that the design of vessels cooled by helical coils can be further improved. The design of these reactors follows very much the geometry proposed by Oldshue and Gretton (1954, and some minor modifications in the coil arrangements are likely to improve internal circulation inside these vessels mainly in the region between coils and wall of the vessel. Results show a gain in performance when small alterations are made specially in the shape of the coil arrangement.

  17. High-quality Critical Heat Flux in Horizontally Coiled Tubes

    Institute of Scientific and Technical Information of China (English)

    1995-01-01

    An investigation on the high-quality dryout in two electrically heated coiled tubes with horizontally helix axes is reported.The temperature profiles both along the tube and around the circumference are measured.and it is found that the temperature profiles around the circumference are not identical for the corss-sections at different parts of the coil.The “local condition hypothesis” seems applicable under present conditions,and the critical heat flux qcr decreases with increasing critical quality xcr.The CHF increases as mass velocity and ratio of tube diameter to coil diameter(d/D) increases,and it seems not to be affected hby the system pressure.The CHF is larger with coils than that with straight tubes,and the difference increases with increasing mass velocity and d/D.

  18. Convective heat transfer enhancement inside tubes using inserted helical coils

    Science.gov (United States)

    Ali, R. K.; Sharafeldeen, M. A.; Berbish, N. S.; Moawed, M. A.

    2016-01-01

    Convective heat transfer was experimentally investigated in tubes with helical coils inserts in turbulent flow regime within Reynolds number range of 14400 ≤ Re ≤ 42900. The present work aims to extend the experimental data available on wire coil inserts to cover wire diameter ratio from 0.044 to 0.133 and coil pitch ratio from 1 to 5. Uniform heat flux was applied to the external surface of the tube and air was selected as fluid. The effects of Reynolds number and wire diameter and coil pitch ratios on the Nusselt number and friction factor were studied. The enhancement efficiency and performance criteria ranges are of (46.9-82.6%) and (100.1-128%) within the investigated range of the different parameters, respectively. Correlations are obtained for the average Nusselt number and friction factor utilizing the present measurements within the investigated range of geometrical parameters and Re.

  19. The Role of Filtration in Maintaining Clean Heat Exchanger Coils

    Energy Technology Data Exchange (ETDEWEB)

    Li Yang; James E. Braun; Eckhard A. Groll

    2004-06-30

    The main purpose of the study was to investigate the role of filtration in maintaining clean heat exchanger coils and overall performance. Combinations of 6 different levels of filtration (MERV 14, 11, 8, 6, 4, and no filter) and 4 different coils (an eight-row lanced-fin coil, HX8L), (an eight-row wavy-fin coil, HX8W), (a four-row lanced-fin coil, HX4L) and (a two-row lanced-fin coil, HX2L) were tested at 4 different air velocities (1.52, 2.03, 2.54,3.05 m/s (300, 400, 500, 600 ft/min)). The fouled conditions were obtained after injection of 600 grams of ASHRAE standard dust upstream of the filter/coil combination. This magnitude of dust is representative of a year of normal operation for an air conditioning system. The air-side pressure drops of the coils and filters and air-side heat transfer coefficients of the coils were determined from the measurements under the clean and fouled conditions. Depending upon the filter and coil test, the coil pressure drops increased in the range of 6%-30% for an air velocity at 2.54 m/s (500 ft/min). The impact was significantly greater for tests performed without a filter. The largest relative effect of fouling on pressure drop occurs for coils with fewer rows and having lanced fins. Coils with a greater number of rows can hold more dust so that a fixed amount of dust has a relatively smaller impact. The impact of fouling on air-side heat transfer coefficients was found to be relatively small. In some cases, heat transfer was actually enhanced due to additional turbulence caused by the presence of dust. The experimental results for pressure drops and heat transfer coefficients were correlated and the correlations were implemented within computer models of prototypical rooftop air conditioners and used to evaluate the impact of fouling on cooling capacity and EER. The equipment cooling capacity is reduced with fouling primarily because of a decrease in air flow due to the increase pressure drop rather than due to changes in h

  20. Novel Coil Winding Method to Realize Pot Heated Evenly

    Institute of Scientific and Technical Information of China (English)

    Mao-Yan Wang; Hai-Long Li; Meng Zhang; Zhi-Tao Xu; Cui-Lin Zhong; Jun Xu

    2015-01-01

    To solve the problem about the inhomogeneous thermal effect of pot heated by coils along the circumference, a novel coil winding method is proposed and compared with the general winding method in the paper. First, based on the Biot-Savart law and Ampere’s rule, the magnetic induction generated by a straight current carrying conductor and a current loop is discussed, respectively. Then the novel coil winding method is developed by adjusting the location of inhomogeneous joints. The joints are periodically scattered along the circumferential direction and symmetrically designed around the central axis. Numerical results show that the quite non-uniform temperature in the base of pot at the circular direction is effectively improved by using the proposed winding method. The potential danger produced by high temperature at some region of coils plate is minimized. It is energy-efficient and safe for residential appliances.

  1. Experimental investigation on heat transfer analysis of conical coil heat exchanger with 90° cone angle

    Science.gov (United States)

    Purandare, Pramod S.; Lele, Mandar M.; Gupta, Raj Kumar

    2015-03-01

    In the present study, an experimental investigation on thermal performance of the conical coil heat exchanger with 90° conical coil heat exchanger is reported. Three different conical coil heat exchangers of same mean coil diameter (Dm = 200 mm) with different tube diameters ( di = 8, 10, 12.5 mm) are analyzed under steady state condition. The analysis is carried out for the tube side hot fluid flow range of 10-100 lph ( Re = 500-5,000), while the shell side flow range of 30-90 lph. The data available from experimentation leads to evaluate heat transfer coefficients for inside and outside the tube of the conical coil heat exchanger by Wilsons plot method. The calculations are further extended to estimate Nusselt Number ( Nu) and effectiveness. The empirical correlations are proposed for predicting Nu and the outlet temperatures of hot and cold fluids. The predicted empirical correlations show reasonable agreement with the experimental results within the given range of parameters.

  2. Tx/Rx Head Coil Induces Less RF Transmit-Related Heating than Body Coil in Conductive Metallic Objects Outside the Active Area of the Head Coil.

    Science.gov (United States)

    Nagy, Zoltan; Oliver-Taylor, Aaron; Kuehne, Andre; Goluch, Sigrun; Weiskopf, Nikolaus

    2017-01-01

    The transmit-receive (Tx/Rx) birdcage head coil is often used for excitation instead of the body coil because of the presumably lower risk of heating in and around conductive implants. However, this common practice has not been systematically tested. To investigate whether the Tx/Rx birdcage head coil produces less heating than the body coil when scanning individuals with implants, we used a 3T clinical scanner and made temperature measurements around a straight 15 cm conductor using either the Tx/Rx body or the head coil for excitation. Additionally, the transmitted fields of a Tx/Rx head coil were measured both in air and in gel using a resonant and a non-resonant B field probes as well as a non-resonant E field probe. Simulations using a finite-difference time domain solver were compared with the experimental findings. When the body coil was used for excitation, we observed heating around the 15 cm wire at various anatomical locations (both within and outside of the active volume of the head coil). Outside its active area, no such heating was observed while using the Tx/Rx head coil for excitation. The E and B fields of the Tx/Rx birdcage head coil extended well-beyond the physical dimensions of the coil. In air, the fields were monotonically decreasing, while in gel they were more complex with local maxima at the end of the ASTM phantom. These experimental findings were line with the simulations. While caution must always be exercised when scanning individuals with metallic implants, these findings support the use of the Tx/Rx birdcage head coil in place of the body coil at 3T in order to reduce the risk of heating in and around conductive implants that are remote from the head coil.

  3. Tx/Rx Head Coil Induces Less RF Transmit-Related Heating than Body Coil in Conductive Metallic Objects Outside the Active Area of the Head Coil

    Science.gov (United States)

    Nagy, Zoltan; Oliver-Taylor, Aaron; Kuehne, Andre; Goluch, Sigrun; Weiskopf, Nikolaus

    2017-01-01

    The transmit–receive (Tx/Rx) birdcage head coil is often used for excitation instead of the body coil because of the presumably lower risk of heating in and around conductive implants. However, this common practice has not been systematically tested. To investigate whether the Tx/Rx birdcage head coil produces less heating than the body coil when scanning individuals with implants, we used a 3T clinical scanner and made temperature measurements around a straight 15 cm conductor using either the Tx/Rx body or the head coil for excitation. Additionally, the transmitted fields of a Tx/Rx head coil were measured both in air and in gel using a resonant and a non-resonant B field probes as well as a non-resonant E field probe. Simulations using a finite-difference time domain solver were compared with the experimental findings. When the body coil was used for excitation, we observed heating around the 15 cm wire at various anatomical locations (both within and outside of the active volume of the head coil). Outside its active area, no such heating was observed while using the Tx/Rx head coil for excitation. The E and B fields of the Tx/Rx birdcage head coil extended well-beyond the physical dimensions of the coil. In air, the fields were monotonically decreasing, while in gel they were more complex with local maxima at the end of the ASTM phantom. These experimental findings were line with the simulations. While caution must always be exercised when scanning individuals with metallic implants, these findings support the use of the Tx/Rx birdcage head coil in place of the body coil at 3T in order to reduce the risk of heating in and around conductive implants that are remote from the head coil.

  4. Examination of Coil Arrangement for Higher Quality Heating of the Induction Heating Cooker

    Science.gov (United States)

    Yonetsu, Daigo; Kawata, Kohei; Hara, Takehisa; Ujiie, Satoshi; Joto, Takaya; Masuda, Tadashi

    This paper proposes effective and practical design method of higher quality heating for induction-heating cooker. The IH cooker which has the simple pancake-shaped coil arrangement produces slightly nonuniform temperature distribution along the heating plate. The object of this research is to achieve the better heating performance by adjusting the arrangement of the coil. Easiness of coil winding is added to the evaluation basis. Eddy current analysis is made by the finite element method for calculating the heat distribution of the heating plate. After this, heat transfer analysis is made by the finite element method for calculating the temperature distribution of the heating plate. Multi-objective genetic algorithm is employed for obtaining the optimum arrangement of the coil. The two objectives that mean the uniformity of temperature distribution and the easiness of coil winding are both evaluated. By using the proposed method, we could obtain the expected coil arrangement easily. The temperature distribution approaches closer to uniform distribution by using the obtained coil arrangement which is not difficult to wind.

  5. Optimum Construction of Heating Coil for Domestic Induction Cooker

    Science.gov (United States)

    Sinha, Dola; Bandyopadhyay, Atanu; Sadhu, Pradip Kumar; Pal, Nitai

    2010-10-01

    The design and optimization of the parameters of heating coil is very important for the analytical analysis of high frequency inverter fed induction cooker. Moreover, accurate prediction of high frequency winding loss (i.e., losses due to skin and proximity effects) is necessary as the induction cooker used in power electronics applications. At high frequency current penetration in the induction coil circuit is very difficult for conducting wire due to skin-effect. To eradicate the skin effect heating coil is made up of bundle conductor i.e., litz wire. In this paper inductances and AC resistances of a litz-wire are calculated and optimized by considering the input parameters like wire type, shape, number of strand, number of spiral turn, number of twist per feet of heating coil and operating frequency. A high frequency half bridge series resonant mirror inverter circuit is used in this paper and taking the optimum values of inductance and ac resistance the circuit is simulated through PSPICE simulations. It has been noticed that the results are feasible enough for real implementation.

  6. Temperature Profile Measurements During Heat Treatment of BSCCO 2212 Coils

    Energy Technology Data Exchange (ETDEWEB)

    Tollestrup, Alvin; /Fermilab

    2011-04-14

    The temperature profile of two different BSCCO 2212 coils has been analyzed. The profiles are obtained from thermocouples imbedded in the windings during the heat treatment that activates the 2212. The melting and freezing of the 2212 is clearly observed. A model that describes the data and can be used to guide the processing of new coils has been developed. We have obtained the thermal history of two BSCCO coils, one from NHMFL (1) that had 10 layers of 1 mm diameter wire with 0.15 mm insulation and a second coil from OST that had 24 layers with similar insulation and conductor size. Both coils had thermocouples imbedded in the windings and excellent recordings of the temperature over the whole reaction cycle were available for analysis. There are several features that we will address in this note. Measurements have shown that the I{sub c} of the conductor is a sensitive function of its thermal history. This brings up the question of the absolute accuracy of the thermometry in the range around 882 C, the MP of 2212. The reference for the treatment profile is really related to this MP and to small deviations around it. Since the heat of fusion of 2212 is rather large, it generates a clear signal during the melting and cooling transition that automatically generates the relative temperature markers. The physics is the same as the way ice in water maintains an isothermal environment until it is all melted. A related question is the thermal response time of the coil package. The temperature cycles that are being used to optimize strand and small coils can have rapid changes easily implemented whereas a large coil may have such a large thermal time constant that the optimum cycle may not be attainable. A simple analytical model that works well for small solenoids has been developed and an ANSYS (5) program that works for larger coils with more complicated geometry has been set up but will not be discussed in this note.

  7. Heat transfer characteristics of a new helically coiled crimped spiral finned tube heat exchanger

    Science.gov (United States)

    Srisawad, Kwanchanok; Wongwises, Somchai

    2009-02-01

    In the present study, the heat transfer characteristics in dry surface conditions of a new type of heat exchanger, namely a helically coiled finned tube heat exchanger, is experimentally investigated. The test section, which is a helically coiled fined tube heat exchanger, consists of a shell and a helical coil unit. The helical coil unit consists of four concentric helically coiled tubes of different diameters. Each tube is constructed by bending straight copper tube into a helical coil. Aluminium crimped spiral fins with thickness of 0.5 mm and outer diameter of 28.25 mm are placed around the tube. The edge of fin at the inner diameter is corrugated. Ambient air is used as a working fluid in the shell side while hot water is used for the tube-side. The test runs are done at air mass flow rates ranging between 0.04 and 0.13 kg/s. The water mass flow rates are between 0.2 and 0.4 kg/s. The water temperatures are between 40 and 50°C. The effects of the inlet conditions of both working fluids flowing through the heat exchanger on the heat transfer coefficients are discussed. The air-side heat transfer coefficient presented in term of the Colburn J factor is proportional to inlet-water temperature and water mass flow rate. The heat exchanger effectiveness tends to increase with increasing water mass flow rate and also slightly increases with increasing inlet water temperature.

  8. Research of the heat exchanging processes running in the heating and hot water supply loops of the coil heat exchangers

    Directory of Open Access Journals (Sweden)

    Ірина Геннадіївна Шитікова

    2016-11-01

    Full Text Available The fuel-energy complex research has made it possible to disclose a huge power-saving potential in the municipal heat-and-power engineering. Power-and-resource-saving units and systems are becoming extremely urgent because of the power engineering crisis expansion. The self-adjusting heat supply system from the individual heating points with the heat-accumulating units and coil heat exchangers for independent heating and water supply systems has been examined. Coil heat exchangers are used in municipal heating for heat transfer (e.g. geothermal waters for the independent mains of the heating and hot water supply systems. The heat engineering calculation of the heating and accumulating unit with the coil heat exchanger for independent heat supply systems from individual heater was performed and experimental data were received at the experimental industrial unit under the laboratory conditions. The peculiarities of the flows in the intertubular space, their influence on the heat exchange and temperatures of the first and intermediate mains have been shown. It is important to know the processes running inside the apparatus to be able to improve the technical characteristics of the three-loop coil heat exchanger. The task solution will make it possible to save the materials consumption for the three-loop coil heat exchangers in the future

  9. Experimental and numerical study on unsteady natural convection heat transfer in helically coiled tube heat exchangers

    Science.gov (United States)

    Neshat, E.; Hossainpour, S.; Bahiraee, F.

    2014-06-01

    Both of experimental and numerical investigations were performed to understand unsteady natural convection from outer surface of helical coils. Four helical coils with two different curvature ratios were used. Each coil was mounted in the shell both vertically and horizontally. The cold water was entered the coil and the hot water in the shell was cooling by unsteady natural convection. A CFD code was developed to simulate natural convection heat transfer. Equations of tube and shell are solved simultaneously. Statistical analyses have been done on data points of temperature and natural convection Nusselt number. It was revealed that shell-side fluid temperature and the Nusselt number of the outer surface of coils are functions of in-tube fluid mass flow rate, specific heat of fluids and geometrical parameters including length, inner diameter of the tube and the volume of the shell, and time.

  10. Heat Transfer Characteristics and Performance of a Spirally Coiled Heat Exchanger under Sensible Cooling Conditions

    Science.gov (United States)

    Wongwises, Somchai; Naphon, Paisarn

    In the present study, new experimental data on the heat transfer characteristics and the performance of a spirally coiled heat exchanger under sensible cooling conditions is presented. The spiral-coil heat exchanger consists of a steel shell and a spirally coiled tube unit. The spiral-coil unit consists of six layers of concentric spirally coiled tubes. Each tube is fabricated by bending a 9.27mm diameter straight copper tube into a spiral-coil of five turns. The innermost and outermost diameters of each spiral-coil are 67.7 and 227.6mm, respectively. Air and water are used as working fluids in shell side and tube side, respectively. A mathematical model based on the conservation of energy is developed to determine the heat transfer characteristics. There is a reasonable agreement between the results obtained from the experiment and those obtained from the model and a good agreement for the high air mass flow rate region. The results obtained from the parametric study are also discussed.

  11. Research on ground heat exchanger of Ground Source Heat Pump technique

    Institute of Scientific and Technical Information of China (English)

    LIU Dong-sheng; SUN You-hong; GAO Ke; WU Xiao-hang

    2004-01-01

    Ground Source Heat Pump technique and its operating principle are described in this paper. Ground heat exchanger is the key technique of ground source heat pump and its pattems are discussed. Software is helpful to design ground heat exchanger. A project of Chinese Ground Source Heat Pump is introduced and its market is more and more extensive.

  12. Promoted-Combustion Chamber with Induction Heating Coil

    Science.gov (United States)

    Richardson, Erin; Hagood, Richard; Lowery, Freida; Herald, Stephen

    2006-01-01

    An improved promoted-combustion system has been developed for studying the effects of elevated temperatures on the flammability of metals in pure oxygen. In prior promoted-combustion chambers, initial temperatures of metal specimens in experiments have been limited to the temperatures of gas supplies, usually near room temperature. Although limited elevated temperature promoted-combustion chambers have been developed using water-cooled induction coils for preheating specimens, these designs have been limited to low-pressure operation due to the hollow induction coil. In contrast, the improved promoted-combustion chamber can sustain a pressure up to 10 kpsi (69 MPa) and, through utilization of a solid induction coil, is capable of preheating a metal specimen up to its melting point [potentially in excess of 2,000 F (approximately equal to 1,100 C)]. Hence, the improved promoted combustion chamber makes a greater range of physical conditions and material properties accessible for experimentation. The chamber consists of a vertical cylindrical housing with an inner diameter of 8 in. (20.32 cm) and an inner height of 20.4 in. (51.81 cm). A threaded, sealing cover at one end of the housing can be unscrewed to gain access for installing a specimen. Inlet and outlet ports for gases are provided. Six openings arranged in a helical pattern in the chamber wall contain sealed sapphire windows for viewing an experiment in progress. The base of the chamber contains pressure-sealed electrical connectors for supplying power to the induction coil. The connectors feature a unique design that prevents induction heating of the housing and the pressure sealing surfaces; this is important because if such spurious induction heating were allowed to occur, chamber pressure could be lost. The induction coil is 10 in. (25.4 cm) long and is fitted with a specimen holder at its upper end. At its lower end, the induction coil is mounted on a ceramic base, which affords thermal insulation to

  13. 46 CFR 153.434 - Heat transfer coils within a tank.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 5 2010-10-01 2010-10-01 false Heat transfer coils within a tank. 153.434 Section 153... Cargo Temperature Control Systems § 153.434 Heat transfer coils within a tank. When a cargo tank... the heat transfer fluid at a pressure greater than the pressure exerted on the heating or...

  14. Experimental investigation on heat transfer and pressure drop of conical coil heat exchanger

    Directory of Open Access Journals (Sweden)

    Purandare Pramod S.

    2016-01-01

    Full Text Available The heat transfer and pressure drop analysis of conical coil heat exchanger with various tube diameters, fluid flow rates, and cone angles is presented in this paper. Fifteen coils of cone angles 180° (horizontal spiral, 135°, 90°, 45°, and 0° (vertical helical are fabricated and analysed with, same average coil diameter, and tube length, with three different tube diameters. The experimentation is carried out with hot and cold water of flow rate 10 to 100 L per hour (Reynolds range 500 to 5000, and 30 to 90 L per hour, respectively. The temperatures and pressure drop across the heat exchanger are recorded at different mass flow rates of cold and hot fluid. The various parameters: heat transfer coefficient, Nusselt number, effectiveness, and friction factor, are estimated using the temperature, mass flow rate, and pressure drop across the heat exchanger. The analysis indicates that, Nusselt number and friction factor are function of flow rate, tube diameter, cone angle, and curvature ratio. Increase in tube side flow rate increases Nusselt number, whereas it reduces with increase in shell side flow rate. Increase in cone angle and tube diameter, reduces Nusselt number. The effects of cone angle, tube diameter, and fluid flow rates on heat transfer and pressure drop characteristics are detailed in this paper. The empirical correlations are proposed to bring out the physics of the thermal aspects of the conical coil heat exchangers.

  15. An optimized ground-coupled heat pump system design for northern climate applications

    Energy Technology Data Exchange (ETDEWEB)

    Catan, M.A.; Baxter, V.D.

    1985-01-01

    This paper addresses the question of the performance of a ground coupled heat pump (GCHP) system with a water-source heat pump package designed expressly for such systems operating in a northern climate. The project objective was to minimize the life-cycle cost of a GCHP system by optimizing the design of both the heat pump package and the group coil in concert. In order to achieve this objective, a number of modelling tools were developed to analyze the heat pump's performance and cost, and the ground coil's performance.

  16. Evaluation of the heat transfer performance of helical coils of non-circular tubes

    Institute of Scientific and Technical Information of China (English)

    Jundika C.KURNIA; Agus P.SASMITO; Arun S.MUJUMDAR

    2011-01-01

    This study addresses heat transfer performance of various configurations of coiled non-circular tubes, e. g. , in-plane spiral ducts, helical spiral ducts, and conical spiral ducts. The laminar flow of a Newtonian fluid in helical coils made of square cross section tubes is simulated using the computational fluid dynamic approach. The effects of tube Reynolds number, fluid Prandtl number, coil diameter, etc. , are quantified and discussed. Both constant wall temperature and constant heat flux conditions are simulated. The effect of in-plane coil versus a cylindrical design of constant coil, as well as a conical coil design is discussed. Results are compared with those for a straight square tube of the same length as that used to form the coils. Advantages and limitations of using coiled tubes are discussed in light of the numerical results.

  17. Heat Transfer Behavior in a Square Duct with Tandem Wire Coil Element Insert

    Institute of Scientific and Technical Information of China (English)

    Smith Eiamsa-ard; Narin Koolnapadol; Pongjet Promvonge

    2012-01-01

    Effects of insertion of tandem wire coil elements used as turbulator on heat transfer and turbulent flow friction characteristics in a uniform heat-flux square duct are experimentally investigated in this work. The experiment is conducted for turbulent flow with the Reynolds number from 4000 to 25000. The wire coil element is inserted into the duct with a view to generating a swirl flow that assists to wash up the flow trapped in the duct corners and then increase the heat transfer rate of the test duct. Apart from the full-length coil, 1D and 2D length coil elements placed in tandem inside the duct with various free-space lengths are introduced to reduce the friction loss. The results obtained from these wire coil element inserts are also compared with those from the smooth duct. The experimental results reveal that the use of wire coil inserts for the full-length coil, 1D and 2D coil elements with a short free-space length leads to a considerable increase in heat transfer and friction loss over the smooth duct with no insert. The full-length wire coil provides higher heat transfer and friction factor than the tandem wire coil elements under the same operating conditions. Also, performance evaluation criteria to assess the real benefits in using the wire coil insert into the square duct are determined.

  18. Performance of Helical Coil Heat Recovery Exchanger using Nanofluid as Coolant

    Directory of Open Access Journals (Sweden)

    Navid Bozorgan

    2015-07-01

    Full Text Available Nanofluids are expected to be a promising coolant condidate in chemical processes for heat transfer system size reduction. This paper focuses on reducing the number of turns in a helical coil heat recovery exchanger with a given heat exchange capacity in a biomass heating plant using γ-Al2O3/n-decane nanofluid as coolant. The nanofluid flows through the tubes and the hot n-hexane flows through the shell. The numerical results show that using nanofluid as coolant in a helical coil heat exchanger can reduce the manufacturing cost of the heat exchanger and pumping power by reducing the number of turns of the coil.

  19. Performance of multi tubes in tube helically coiled as a compact heat exchanger

    Science.gov (United States)

    Nada, S. A.; El Shaer, W. G.; Huzayyin, A. S.

    2014-12-01

    Multi tubes in tube helically coiled heat exchanger is proposed as a compact heat exchanger. Effects of heat exchanger geometric parameters and fluid flow parameters; namely number of inner tubes, annulus hydraulic diameter, Reynolds numbers and input heat flux, on performance of the heat exchanger are experimentally investigated. Different coils with different numbers of inner tubes, namely 1, 3, 4 and 5 tubes, were tested. Results showed that coils with 3 inner tubes have higher values of heat transfer coefficient and compactness parameter (bar{h} Ah ). Pressure drop increases with increasing both of Reynolds number and number of inner tubes. Correlations of average Nusselt number were deduced from experimental data in terms of Reynolds number, Prandtl number, Number of inner coils tubes and coil hydraulic diameter. Correlations prediction was compared with experimental data and the comparison was fair enough.

  20. Experimental study on in-tube condensation heat transfer characteristics of helically coiled spiral tubes

    Energy Technology Data Exchange (ETDEWEB)

    Park, J.U. [Sunchon First College, Sunchon (Korea); Kweon, Y.C. [Sun Moon University, Chonan (Korea); Han, K.I. [Pukyong National University, Pusan (Korea)

    2001-12-01

    An experimental study on condensation heat transfer characteristics of helically coiled spiral tubes was performed. The refrigerant is R-113. A refrigerant loop was established to measure the condensation heat transfer coefficients. Experiments were carried out uniform heat flux of 15 kW/m{sup 2}, refrigerant quality of 0.1 {approx} 0.9, curvature ratio of 0.016, 0.025 and 0.045. The curvature of a coil was defined as the ratio of the inside diameter of the tube to the diameter of the bending circle. To compare the condensation heat transfer coefficients of coiled spiral tubes, the previous results on coiled plain tubes and straight plain tubes were used. The results shows that the condensation heat transfer coefficients of coiled spiral tubes largely increase, as increasing Re and quality, compared to those of coiled plain tubes and straight plain tubes. As increasing degree of subcooling, however, the condensation heat transfer coefficients on coiled spiral tubes decrease. It is found that the heat transfer enhancement is more better than coiled plain tubes and straight plain tubes, as increasing curvature ratio. (author). 13 refs., 10 figs., 1 tab.

  1. Minimax current density gradient coils: analysis of coil performance and heating.

    Science.gov (United States)

    Poole, Michael S; While, Peter T; Lopez, Hector Sanchez; Crozier, Stuart

    2012-08-01

    Standard gradient coils are designed by minimizing the inductance or resistance for an acceptable level of gradient field nonlinearity. Recently, a new method was proposed to minimize the maximum value of the current density in a coil additionally. The stated aim of that method was to increase the minimum wire spacing and to reduce the peak temperature in a coil for fixed efficiency. These claims are tested in this study with experimental measurements of magnetic field and temperature as well as simulations of the performance of many coils. Experimental results show a 90% increase in minimum wire spacing and 40% reduction in peak temperature for equal coil efficiency and field linearity. Simulations of many more coils indicate increase in minimum wire spacing of between 50 and 340% for the coils studied here. This method is shown to be able to increase coil efficiency when constrained by minimum wire spacing rather than switching times or total power dissipation. This increase in efficiency could be used to increase gradient strength, duty cycle, or buildability.

  2. Dynamic models of heating and cooling coils with one-dimensional air distribution

    Science.gov (United States)

    Wang, Zijie; Krauss, G.

    1993-06-01

    This paper presents the simulation models of the plate-fin, air-to-water (or water vapour) heat exchangers used as air-heating or air-cooling and dehumidifying coils in the HVAC (Heating, Ventilation and Air-Conditioning) systems. The thermal models are used to calculate the heat exchange between distributing air and coil pipes and outlet temperatures of air and heat or chilled fluid. The aerodynamic models are used to account for the pressure drop of the air crossing the coil tubes. They can also be used to optimize the structures of such coils. The models are based on principal laws of heat and mass conservation and fluid mechanics. They are transparent and easy to use. In our work, a coil is considered as an assembly of numbers of basic elements in which all the state variables are unique. Therefore we can conveniently simulate the coils with different structures and different geometric parameters. Two modular programs TRNSYS (Transient System Simulation) and ESACAP are utilized as supporting softwares which make the programming and simulation greatly simplified. The coil elements and a real coil were simulated. The results were compared with the data offered by the manufacturer (company SOFICA) and also with those obtained using critical methods such as NTU method, etc. and good agreement is attained.

  3. Experimental and theoretical investigations of special type coil heat exchanger with the nanofluid buffer layer

    Directory of Open Access Journals (Sweden)

    Smusz Robert

    2017-01-01

    Full Text Available The paper presents the results of experimental and theoretical investigations of special type of coil heat exchanger. The tested device is equipped with three vertical coils and the temperature stratification system. Water is a heating medium in two coils. The refrigerant transferring the waste heat from air conditioning system is the heating medium in the third coil. The finned pipe of this coil has a double wall in which the annular buffer layer with nanofluid is mounted. Thermophysical properties of the applied water based Cu nanofluid cause the enhancement of heat transfer through the buffer layer. The paper presents thermal characteristics of the exchanger received on the basis of measurements performed on the industrial test stand. Measurements were conducted during the operation of the coil with refrigerant. Heat loss to the surroundings, distributions of water temperature in the storage tank, changes of water temperature in time and thermal power of the coil heat exchanger were obtained. The measurement results were compared with those received on the basis of theoretical analysis of the exchanger.

  4. Reduction of implant RF heating through modification of transmit coil electric field.

    Science.gov (United States)

    Eryaman, Yigitcan; Akin, Burak; Atalar, Ergin

    2011-05-01

    In this work, we demonstrate the possibility to modify the electric-field distribution of a radio frequency (RF) coil to generate electric field-free zones in the body without significantly altering the transmit sensitivity. Because implant heating is directly related to the electric-field distribution, implant-friendly RF transmit coils can be obtained by this approach. We propose a linear birdcage transmit coil with a zero electric-field plane as an example of such implant-friendly coils. When the zero electric-field plane coincides with the implant position, implant heating is reduced, as we demonstrated by the phantom experiments. By feeding RF pulses with identical phases and shapes but different amplitudes to the two orthogonal ports of the coil, the position of the zero electric-field plane can also be adjusted. Although implant heating is reduced with this method, a linear birdcage coil results in a whole-volume average specific absorption rate that is twice that of a quadrature birdcage coil. To solve this issue, we propose alternative methods to design implant-friendly RF coils with optimized electromagnetic fields and reduced whole-volume average specific absorption rate. With these methods, the transmit field was modified to reduce RF heating of implants and obtain uniform transmit sensitivity. Copyright © 2010 Wiley-Liss, Inc.

  5. Insulation and Heat Treatment of Bi-2212 Wire for Wind-and-React Coils

    Energy Technology Data Exchange (ETDEWEB)

    Peter K. F. Hwang

    2007-10-22

    Higher Field Magnets demand higher field materials such as Bi-2212 round superconducting wire. The Bi-2212 wire manufacture process depends on the coil fabrication method and wire insulation material. Considering the wind-and-react method, the coil must unifirmly heated to the melt temperature and uniformly cooled to the solidification temperature. During heat treat cycle for tightly wound coils, the leakage melt from conductor can chemically react with insulation on the conductor and creat short turns in the coils. In this research project, conductor, insulation, and coils are made to systemically study the suitable insulation materials, coil fabrication method, and heat treatment cycles. In this phase I study, 800 meters Bi-2212 wire with 3 different insulation materials have been produced. Best insulation material has been identified after testing six small coils for insulation integrity and critical current at 4.2 K. Four larger coils (2" dia) have been also made with Bi-2212 wrapped with best insulation and with different heattreatment cycle. These coils were tested for Ic in a 6T background field and at 4.2 K. The test result shows that Ic from 4 coils are very close to short samples (1 meter) result. It demonstrates that HTS coils can be made with Bi-2212 wire with best insulation consistently. Better wire insulation, improving coil winding technique, and wire manufacture process can be used for a wide range of high field magnet application including acclerators such as Muon Collider, fusion energy research, NMR spectroscopy, MRI, and other industrial magnets.

  6. Comparative Study and Analysis between Helical Coil and Straight Tube Heat Exchanger

    Directory of Open Access Journals (Sweden)

    N. D. Shirgire

    2014-08-01

    Full Text Available The purpose of this study is to determine the relative advantage of using a helically coiled heat exchanger against a straight tube heat exchanger. It is found that the heat transfer in helical circular tubes is higher as compared to Straight tube due to their shape. Helical coils offer advantageous over straight tubes due to their compactness and increased heat transfer coefficient. The increased heat transfer coefficients are a consequence of the curvature of the coil, which induces centrifugal forces to act on the moving fluid, resulting in the development of secondary flow. The curvature of the coil governs the centrifugal force while the pitch (or helix angle influences the torsion to which the fluid is subjected to the centrifugal force results in the development of secondary flow. Due to the curvature effect, the fluid streams in the outer side of the pipe moves faster than the fluid streams in the inner side of the pipe. In current work the fluid to fluid heat exchange is taken into consideration. Most of the investigations on heat transfer coefficients are for constant wall temperature or constant heat flux. The effectiveness, overall heat transfer coefficient, effect of cold water flow rate on effectiveness of heat exchanger when hot water mass flow rate is kept constant and effect of hot water flow rate on effectiveness when cold water flow rate kept constant studied and compared for parallel flow, counter flow arrangement of Helical coil and Straight tube heat exchangers. All readings were taken at steady state condition of heat exchanger. The result shows that the heat transfer coefficient is affected by the geometry of the heat exchanger. Helical coil heat exchanger are superior in all aspect studied here.

  7. Dynamic Models of Heating and Cooling Coils with One—Dimensional Air Distribution

    Institute of Scientific and Technical Information of China (English)

    WangZijie; G.Krauss

    1993-01-01

    This paper presents the simulation models of the plate-fin,air-to-water(or water vapour) heat exchangers used as air-heating or air-cooling and dehumidifying colis in the HVAC(Heating,Ventilation and AIr-Conditioning)systems.The thermal models are used to calculate the heat exchange between distributing air and coil pipes and outlet temperatures of air and heat or chilled fluid.The aerodynamic models are used to account for the pressure drop of the air crossing the coil tubes,They can also be used to optimize the structres of such coils.The models are based on principal laws of teat and mass conservation and fluid mechanics.They are transparent and easy to use.In our work,a coil is considered as an assembly of numbers of basic elements in which all the state variables are unique.Therefore we can conveniently simulate the coils with different structures and different geometric parameters.Two modular programs TRNSYS(Transient System Simulation)and ESACAP are utilized as supporting softwares which make the programming and simulation greatly simplified.The coil elements and a real coil were simulated.The results were compared with the data offered by the manufacturer(company SOFICA) and also with those obtained using critical methods such as NTU method ,etc.and good agreement is attained.

  8. Experimental Study of Heat Transfer Enhancement in a Heated Tube Caused by Wire-Coil and Rings

    OpenAIRE

    Saeed Vahidifar; M. Kahrom

    2015-01-01

    This study investigates heat transfer characteristics and the pressure drop of a horizontal double pipe heat exchanger with wire coil inserts. The amplification of convection heat transfer coefficient in the heat exchanger reduces the weight, size and cost of heat exchanger. One way of augmenting the heat transfer is to disturb the boundary layer. When an object is placed in a boundary layer, it affects the flow structure and alters the velocity and thermal profiles. The change is affected by...

  9. Ground Source Heat Pump in Heating System with Electronics Monitoring

    Directory of Open Access Journals (Sweden)

    NEAMŢU Ovidiu

    2013-10-01

    Full Text Available The monitoring system is implemented for a ground coupled heat pump in heating/ system. The borehole heat exchangers – which are 150 m long - are filled with a mixture of water and ethilene glycol calledbrine. Metering and monitoring energy consumption is achieved for: heat pump, circulation pumps, additional electrical heating, hot air ventilation systems, control systems with sensors: analog and smart sensors. Instantaneous values are stored in a local computer.

  10. Joule heating of the ITER TF cold structure: Effects of vertical control coil currents and ELMS

    Energy Technology Data Exchange (ETDEWEB)

    Radovinsky, A.; Pillsbury, R.D. Jr.

    1993-11-09

    The toroidal field coil and support structures for ITER are maintained at cryogenic temperatures. The time-varying currents in the poloidal field coil system will induce eddy currents in these structures. The associated Joule dissipation will cause local heating and require heat removal which will show up as a load on the cryogenic system. Studies of Joule heating of the ITER TF cold structure (TFCS) due to the currents in the poloidal field coil system are presented. The two regimes considered in this study are the plasma vertical stability control and the Edge Loss Mode (ELM) events. The 3-D, thin-shell, eddy current program, EDDYCUFF was used to analyze the eddy currents and Joule losses in the cold structure. The current versus time scenarios were defined. Four control coil options were studied. All schemes use coils external to the TF cold structure. Analyses of power depositions during the plasma vertical stability control were performed for each of the four options. For each of these options three different recovery times were assumed. The times were 3, 1, and 1/3 seconds. Sets of four sequential ELMs, as well as isolated ELMs have been studied for various sets of active PF coils. The results showed that the lowest average power dissipation in the TF cold structure occurs when a subset of PF2 and PF7 are active, and all the other PF coils are passive. The general conclusion is that to minimize power dissipation in the TF cold structure it is preferable that only coils PF2 and PF7 are active. The other coils (PF3-PF6) should be passive and driven by a condition of constant flux. It is recommended in particular, that coils PF3 and PF5 be allowed to change currents to conserve flux, since they provide the maximum shielding of the TFCS from the fields caused by the active coils.

  11. Fabrication of Coiled Tubular Heat Exchanger%绕管式换热器的制造

    Institute of Scientific and Technical Information of China (English)

    王自涛

    2015-01-01

    本文介绍了绕管换热器的技术特点及应用。从结构设计、技术等方面阐明了绕管换热器的设计制造的问题。%In is paper,the technical characteristics and application of coiled tubular heat exchanger were introduced. And the problem in design and manufacture of coiled tubular heat exchanger were clarified .

  12. Experimental Study of Heat Transfer Enhancement in a Heated Tube Caused by Wire-Coil and Rings

    Directory of Open Access Journals (Sweden)

    Saeed Vahidifar

    2015-01-01

    Full Text Available This study investigates heat transfer characteristics and the pressure drop of a horizontal double pipe heat exchanger with wire coil inserts. The amplification of convection heat transfer coefficient in the heat exchanger reduces the weight, size and cost of heat exchanger. One way of augmenting the heat transfer is to disturb the boundary layer. When an object is placed in a boundary layer, it affects the flow structure and alters the velocity and thermal profiles. The change is affected by the formation of jets and wakes in the boundary layer as it alters modifies transfer and friction coefficients on the wall. This paper studies the characteristics of the heat transfer and the pressure drop of a double pipe horizontal tube heat exchanger with an inserted wire coil and rings. Wire coil acts as a swirl flow, which increases turbulence and roughness whereas rings increase heat transfer as a promoter of turbulence and roughness. The experimental data sets were extracted from wire coils and rings tested within a geometrical range with a pitch of (P/D=1, 2, 4 and wire diameter of (d/D=0.05, 0.07, 0.11. For wire coil with d/D=0.11, P/D =1 and Reynolds number of 10000, the overall enhancement efficiency amounted to 128%.

  13. Crawl space assisted heat pump. [using stored ground heat

    Science.gov (United States)

    Ternes, M. P.

    1980-01-01

    A variety of experiments and simulations, currently being designed or underway, to determine the feasibility of conditioning the source air of an air to air heat pump using stored ground heat or cool to produce higher seasonal COP's and net energy savings are discussed. The ground would condition ambient air as it is drawn through the crawl space of a house. Tests designed to evaluate the feasibility of the concept, to determine the amount of heat or cool available from the ground, to study the effect of the system on the heating and cooling loads of the house, to study possible mechanisms which could enhance heat flow through the ground, and to determine if diurnal temperature swings are necessary to achieve successful system performance are described.

  14. Experimental Study of Effect of Air Duct Structures on Heat Dissipation of Heating-Only Fan Coil

    Institute of Scientific and Technical Information of China (English)

    WU Xiao-zhou; ZHAO Jia-ning

    2009-01-01

    Heating-only fan coil(HFC) is one of the suited end users.which is not only compact but also highly efficient.And the major factors affecting the heat dissipation performance of HFC include leakage through coil bypass,distance between fan and coil,fan structure and air inlet type.Under natural air convection or forced,experimental studies were made on the effects of these factors upon the heat dissipation performance of HFC.The results show that:1)After reducing the leakage through coil bypass,the heat dissipation of HFC in-creases 16.9%under natural convection,and increases 8.3%under forced convection.2)After the distance be-tween fan and coil be raised from 23.2cm to 41.7cm.the heat dissipation of HFC decreases 21.3%under natu-ral convection,but increasesl2.8%under forced convection.3)After changing the fan structure,the heat dissi-pation of HFC increases 41.8%under natural convection.and the heat dissipation per motor power increases 96.1%under forced convection.4)The heat dissipations of HFC with round pass,slit and strip type of air inlet are different,whose proportion is about 100%,110%,136%under natural convection,and 100%,105%,116%under forced convection.

  15. VENTILATION SYSTEM WITH GROUND HEAT EXCHANGER

    Directory of Open Access Journals (Sweden)

    Vyacheslav Pisarev

    2016-11-01

    Full Text Available Ventilation systems consume more and more energy because of the often complex treatment of the air supplied to closed spaces. Looking for sources of energy allow for significant savings costs, which often translate into renewable energy sources. One of the more popular solutions is to use energy from the ground by various methods. Known and relatively common solutions are based on ground heat exchanger and ground collector cooperating with a heat pump. The paper presents the possibility of cooperation ventilation system with ground air heat exchanger and heat pump both in summer and winter period. A number solutions of this type of system, supported by calculation examples and moist air transformation in the Moliere chart have been presented. Support ventilation system with renewable energy sources allows significant savings in operating as shown in the article.

  16. Experimental studies on effect of wire coiled coil matrix turbulators with and without bonding on the wall of the test section of concentric tube heat exchanger

    Directory of Open Access Journals (Sweden)

    Selvam S.

    2012-01-01

    Full Text Available This paper presents the effect of bonding and without bonding of wire coiled coil matrix turbulator on the heat transfer for a fully developed turbulent flow. Experiments are conducted by maintaining constant wall temperature. Tests are performed on 3 different wire coiled coil matrix turbulators of different pitches of 5, 10 and 15 mm without bonding of the turbulator. Three similar types of heat exchangers are fabricated and the wire coiled coil matrix turbulators with different pitches of 5, 10 and 15mm are inserted in the heat exchangers and bonding is done on the surface of the tube section. Results have indicated that the heat transfer rate enhances inversely with the pitch of the wire coiled coil matrix turbulator with bonding. With a pitch of 5 mm, the turbulators without bonding have resulted in almost 25.4% enhancement when compared with plain tube. On the other hand, for pitches of 10 mm and 15 mm the enhancement were 20.7% and 16.8%, respectively. The empirical correlations developed for turbulators with and without bonding results in ±6% deviation for Nusselt number and ±3% for friction factor. Similarly with a pitch of 5 mm, the turbulators with bonding have resulted in almost 42% enhancement. For pitches of 10mm and 15mm the enhancements were 34.7% and 25%, respectively.

  17. Evaluation of immersion coil designs for natural convection-driven batch cooling or heating in tanks

    Energy Technology Data Exchange (ETDEWEB)

    Joye, Donald D.; Smith, Michael A.

    2000-09-01

    Various designs of immersion coils for batch cooling or heating of liquids in tanks were investigated to determine which design was most efficient. This equipment has direct utility in chemical batch processing operations and, particularly, wort cooling - a critical step in small-scale batch brewing of beer. This operation does not use a stirrer or agitation for a variety of reasons, hence it is dependent on natural-convection mechanisms for heat transfer, yet quick cooling is desired. Four basic coil designs with several permutations were evaluated. The results fell into four groups - best, good, mediocre, and worst performers. We found that coil placement and shape were design parameters that had a critical effect on the rate of cooling. Coil spacing also had a significant effect on the cooling rate when it was less than about 2 diameters. (Author)

  18. Thermoeconomic Optimization of a Combined Heating and Humidification Coil for HVAC Systems

    Science.gov (United States)

    Teodoros, Liliana; Andresen, Bjarne

    2016-07-01

    The total cost of ownership is calculated for a combined heating and humidification coil of an air-handling unit taking into account investment and operation costs simultaneously. This total cost represents the optimization function for which the minimum is sought. The parameters for the cost dependencies are the physical dimensions of the coil: length, width and height. The term "coil" is used generically since in this setup it generates heating as well as humidification in a single unit. The first part of the paper deals with the constructive optimization and finds the relationship between the dimensions for a minimum cost. The second part of the paper takes the results of the constructive optimization further and, based on the data derived in our previous papers, analyzes the minimum total cost for the humidification coil while balancing the amount of water used to humidify the air and modify its temperature.

  19. Multiple source ground heat storage

    Science.gov (United States)

    Belzile, P.; Lamarche, L.; Rousse, D. R.

    2016-09-01

    Sharing geothermal borefields is usually done with each borehole having the same inlet conditions (flow rate, temperature and fluid). The objective of this research is to improve the energy efficiency of shared and hybrid geothermal borefields by segregating heat transfer sources. Two models are briefly presented: The first model allows the segregation of the inlet conditions for each borefields; the second model allows circuits to be defined independently for each leg of double U-tubes in a borehole. An application couples residential heat pumps and arrays of solar collectors. Independent circuits configuration gave the best energy savings in a symmetric configuration, the largest shank spacing and with solar collectors functioning all year long. The boreholes have been shortened from 300 m to 150 m in this configuration.

  20. Turbulent flow regime in coiled tubes: local heat-transfer coefficient

    Science.gov (United States)

    Bozzoli, F.; Cattani, L.; Mocerino, A.; Rainieri, S.

    2017-08-01

    Wall curvature represents a widely adopted technique for enhancing heat transfer: the fluid flowing inside a coiled pipe experiences the centrifugal force and this phenomenon induces local maxima in the velocity distribution that locally increase the temperature gradients at the wall by enhancing the heat transfer both in the laminar and in the turbulent flow regime. Consequently, the distribution of the velocity field over the cross-section of the tube is strongly uneven thus leading to significant variations along the circumferential angular coordinate of the convective heat-transfer coefficient at the wall internal surface: in particular, it shows higher values at the outer bend side of the coil than at the inner bend side. The aim of the present work is to estimate experimentally the local convective heat-transfer coefficient at the fluid wall interface in coiled tubes when turbulent flow regime occurs. In particular, the temperature distribution maps on the external coil wall are employed as input data of the inverse heat conduction problem in the wall and a solution approach based on the Tikhonov regularisation is implemented. The results, obtained with water as working fluid, are focused on the fully developed region in the turbulent flow regime in the Reynolds number range of 5000 to 12,000. For the sake of completeness, the overall efficiency of the coiled tubes under test is assessed under a first-law performance evaluation criterion.

  1. Experimental analysis of direct-expansion ground-coupled heat pump systems

    Science.gov (United States)

    Mei, V. C.; Baxter, V. D.

    1991-09-01

    Direct-expansion ground-coil-coupled (DXGC) heat pump systems have certain energy efficiency advantages over conventional ground-coupled heat pump (GCHP) systems. Principal among these advantages are that the secondary heat transfer fluid heat exchanger and circulating pump are eliminated. While the DXGC concept can produce higher efficiencies, it also produces more system design and environmental problems (e.g., compressor starting, oil return, possible ground pollution, and more refrigerant charging). Furthermore, general design guidelines for DXGC systems are not well documented. A two-pronged approach was adopted for this study: (1) a literature survey, and (2) a laboratory study of a DXGC heat pump system with R-22 as the refrigerant, for both heating and cooling mode tests done in parallel and series tube connections. The results of each task are described in this paper. A set of general design guidelines was derived from the test results and is also presented.

  2. Passive heating of the ground surface

    Science.gov (United States)

    Tyburczyk, Anna

    2016-03-01

    The phenomenon of phase change is one of the most important contemporary issues of thermal engineering. In particular, this applies to all kinds of heat exchanger systems, which should achieve the highest possible efficiency while reducing investment and operating costs. Some of these systems are heat pipes or thermosyphons, which, among others, are used for the heat transfer, temperature stabilization and the regulation of heat flux density. Additionally, they are passive systems, and therefore do not require an external power supply. Heat pipes can be used to stabilize the surface temperature of roads and driveways. Large heat tubes can be applied for heating the surface of bridges and overpasses, which become icy in unfavorable climatic conditions. The paper presents research on the test facility, whose main component is a long vertical copper fin. The temperature at the base of the fin was kept constant for a given series of measurements. Heat receiving fluid was ethanol at atmospheric pressure. The measurement methodology and the results of investigations were discussed. The surface temperature distribution was measured with the infrared camera, and on this basis the local values of heat flow and the heat transfer coefficient were determined. The results were presented as boiling curves for both the fin with the smooth surface and the one covered with a metal capillary-porous structure. The results obtained are useful in the design of heat exchangers, including passive heating of the ground.

  3. Passive heating of the ground surface

    Directory of Open Access Journals (Sweden)

    Tyburczyk Anna

    2016-01-01

    Full Text Available The phenomenon of phase change is one of the most important contemporary issues of thermal engineering. In particular, this applies to all kinds of heat exchanger systems, which should achieve the highest possible efficiency while reducing investment and operating costs. Some of these systems are heat pipes or thermosyphons, which, among others, are used for the heat transfer, temperature stabilization and the regulation of heat flux density. Additionally, they are passive systems, and therefore do not require an external power supply. Heat pipes can be used to stabilize the surface temperature of roads and driveways. Large heat tubes can be applied for heating the surface of bridges and overpasses, which become icy in unfavorable climatic conditions. The paper presents research on the test facility, whose main component is a long vertical copper fin. The temperature at the base of the fin was kept constant for a given series of measurements. Heat receiving fluid was ethanol at atmospheric pressure. The measurement methodology and the results of investigations were discussed. The surface temperature distribution was measured with the infrared camera, and on this basis the local values of heat flow and the heat transfer coefficient were determined. The results were presented as boiling curves for both the fin with the smooth surface and the one covered with a metal capillary-porous structure. The results obtained are useful in the design of heat exchangers, including passive heating of the ground.

  4. Ground as a possible heat pump source

    Energy Technology Data Exchange (ETDEWEB)

    Lazzarin, R. [Padova Univ. (Germany). Dipt. di Tecnica e Gestione die Istemi Industriali

    2001-06-01

    Heat pumps are devices that can increase the thermal level of heat taken from an available source. Their performances are usually very sensible to the temperatures. This is the reason why sources different from the outside air are welcome, since that source is thermally unfavourable. The ground is a possible very favourable source: temperature variations are damped in the ground so much the more deeper one descends. The variations are also delayed, so that in the coldest period one can find equality very good thermal levels. The two main used systems are: horizontal tubes at a depth between 0.8 and 1.5m and vertical tubes. This last technology has gained an increasing popularity with depths which are sometimes deeper than 100m. It interests a large volume of ground with a comparatively small surface area. It is a technology already widespread in Switzerland (where more than 15.000 ground heat pumps were installed in these years), Germany and Austria. It could be a very favourable technology also in Italy and other mediterranean countries both for the presence of good thermal levels underground with excellent characteristics of heat exchange and for the possible use of the ground as a suitable summer thermal sink. (orig.)

  5. CFD Simulation Studies on the Performance of Rectangular Coil Heat Exchanger

    Science.gov (United States)

    Samsudeen, N.; Anantharaman, N.; Raviraj, Pol.

    2010-10-01

    The simulation studies are made to understand the concept of heat transfer by convection in a rectangular coiled type heat exchanger. The rectangular coil heat exchanger consists of inner and outer coil arrangements with several straight portions and bends so that the exterior flow is very similar to flow within tube-bundles. The present work focuses mainly on exploring the various flow pattern and temperature distribution through the pipe. Computer simulation studies were performed for four different angle of tube bundle inclination (0°, 30°, 60°, and 90°) with two set flow arrangements (inline and staggered arrangement) in the shell side of the heat exchanger. The simulation results show that the effect of the tube bundle inclination on the fluid velocity distribution and the heat transfer performance is observed maximum for the coil with tube bundle inclination angle between 30 degrees and 60 degrees with the staggered arrangement than with the inline arrangement due to proper mixing in the shell side and the outside flow over the tube bundle helps to create turbulence without increasing the velocity in the shell side of the heat exchanger.

  6. Performance and Optimization for a Ground-Coupled Liquid Loop Heat Recovery Ventilation System

    Institute of Scientific and Technical Information of China (English)

    ZHOU Ya-su; Per FAHLEN; Torbj(o)rn LINDHOLM

    2007-01-01

    Ground-coupled heat pumps(GCHP) arecommonly used in residential heating system. To mitigatethe boreholes temperature dropping with operating time, anew exhaust-air recharging system is developed. The newrecharging system can be used in three operational modes.In this paper, a ground-coupled heat recovery ventilation(HRV) model is discussed. A thermal model is set up tofind the optimal brine flow rate and heat transfer allocationratio between exhaust and supply coils for maximum heatrecovery efficiency. Contrary to the conventional liquid-loopHRV systems, the brine temperature entering the exhaustcoil never goes blow zero(0℃), and hence defrosting isneedless in the ground-coupled HRV system. This can makethe ground-coupled HRV system over 20% more efficientthan a conventional HRV system at low outdoortemperatures.

  7. A Hybrid Heating Method for the HT-7U Coils during Vacuum-Pressure Impregnation

    Institute of Scientific and Technical Information of China (English)

    2001-01-01

    The HT-7U superconducting tokamak is a full-superconducting magnetically confined fusion device, The toroidal magnet system of HT-7U is a very important part of the device.In VPI (Vacuum-Pressure Impregnation) process the magnet coils must be heated and degassed before impregnating and must be heated to the gel temperature and then the curing temperature,and keep the two kinds of temperatures for a long period of time after impregnating. Thus the heating method of VPI is critical. In this paper, a hybrid method of combining the internal and external heating for the coils is analyzed, especially the possibility of the internal heating method is proved.

  8. A heat transfer model of a horizontal ground heat exchanger

    Science.gov (United States)

    Mironov, R. E.; Shtern, Yu. I.; Shtern, M. Yu.; Rogachev, M. S.

    2016-04-01

    Ground-source heat pumps are gaining popularity in Eastern Europe, especially those which are using the horizontal ground heat exchanger (GHX). Due to the difficulty of accessing GHX after the installation, materials and the quality of the installation must satisfy the very high requirements. An inaccurate calculation of GHX can be the reason of a scarcity of heat power in a crucial moment. So far, there isn't any appropriate mathematical description of the horizontal GHX which takes into account the mutual influence of GHX pipes on each other. To solve this problem we used the temperature wave approach. As a result, a mathematical model which describes the dependence of the heat transfer rate per unit length of the horizontal GHX pipe on the thermal properties of soil, operating time of GHX and the distance between pipes was obtained. Using this model, heat transfer rates per unit length of a horizontal GHX were plotted as functions of the distance between pipes and operating time. The modeling shows that heat transfer rates decreases rapidly with the distance between pipes lower then 2 meters. After the launch of heat pump, heat power of GHX is reduced during the first 20 - 30 days and get steady after that. The obtained results correlate with experimental data. Therefore the proposed mathematical model can be used to design a horizontal GHX with the optimal characteristics, and predict its capability during operation.

  9. Effect of γ-Al2O3/water nanofluid on the thermal performance of shell and coil heat exchanger with different coil torsions

    Science.gov (United States)

    Elshazly, K. M.; Sakr, R. Y.; Ali, R. K.; Salem, M. R.

    2016-11-01

    This work investigated experimentally the thermal performance of shell and coil heat exchanger with different coil torsions (λ) for γ-Al2O3/water nanofluid flow. Five helically coiled tube (HCT) with 0.0442 ≤ λ ≤ 0.1348 were tested within turbulent flow regime. The average size of γ-Al2O3 particles is 40 nm and volume concentration (φ) is varied from 0 to 2%. Results showed that reducing coil torsion enhances the heat transfer rate and increases HCT-friction factor (fc). Also, it is noticed that HCT average Nusselt number (Nut) and fc of nanofluids increase with increasing γ-Al2O3 volume concentration. The thermal performance index, TPI = (ht,nf/ht,bf)/(ΔPc,nf/ΔPc,bf). increases with increasing nanoparticles concentration, coil torsion, HCT-side inlet temperature and nanofluid flow rate. Over the studied range of HCT-Reynolds number, the average value of TPI is of 1.34 and 2.24 at φ = 0.5% and φ = 2%, respectively. The average value of TPI is of 1.64 at λ = 0.0442 while its average value at λ = 0.1348 is of 2.01. One of the main contributions is to provide heat equipments designers with Nut and fc correlations for practical configurations shell and coil heat exchangers with a wide range of nanofluid concentration.

  10. HEAT TRANSFER OF TiO2/WATER NANOFLUID IN A COILED AGITATED VESSEL WITH PROPELLER

    Institute of Scientific and Technical Information of China (English)

    PERARASU V.T.; ARIVAZHAGAN M.; SIVASHANMUGAM P.

    2012-01-01

    An attempt is made to investigate heat transfer enhancement using nanofluid in a coiled agitated vessel fitted with propeller agitator.The heat transfer coefficient in coiled agitated vessel for water and TiO2/water nanofluid of 3 different volume concentrations (0.10%,0.20% and 0.30%) are estimated and compared.The heat transfer coefficient for nanofluid is found to be higher than that for water and also found to increase with increasing volume concentrations.The enhancement in the convective heat transfer using nanofluid is found to be a maximum of 17.59%.Empirical correlations are separately formed for water and TiO2/water nanofluid as well as found to fit the experimental data within ±5% for water and within ± 10% for nanofluid.

  11. Thermal analysis and testing for DIII-D ohmic heating coil repair

    Energy Technology Data Exchange (ETDEWEB)

    Baxi, C.B.; Anderson, P.M.; Gootgeld, A.M.

    1997-11-01

    The DIII-D ohmic heating (OH) coil solenoid consists of two parallel windings of 48 turns each cooled by water. Each winding is made up of four parallel conductors. Desired thermal capacity of the coil is 20 MJ at a repetition rate of 10 min. One of the conductors started leaking water in July 1995. Since then, the coil has been operated at a reduced thermal load using one winding. An experiment followed by an analysis was undertaken to determine if the OH-coil could be operated at full capacity without cooling the leaking segment by relying on conduction heat transfer to the neighboring cooled conductors. The analysis took into consideration the transient energy equations, including the effect of conduction between neighboring conductors. The axial conduction was modeled in the conductor, but was ignored in the coolant. An experiment was performed on the undamaged coil winding to determine the thermal conductance between neighboring conductors. The experiment consisted of passing hot water through adjacent cooling channels of two conductors and cold water through the cooling channels of the remaining two conductors of the same winding. The flow rate, inlet and outlet temperatures from each circuit were measured during the transient. From the experimental data and analysis an average thermal conductance between the conductors was determined to be about 0.1 W/cm{sup 2}-C. Using the experimentally determined value of the thermal conductance, an analysis was performed on a coil winding consisting of one uncooled conductor and three cooled conductors. Results show that it is possible to operate the full OH-coil without cooling the damaged conductor to the desired thermal load of 20 MJ per pulse.

  12. Nanofluids heat transfer and flow analysis in vertical spirally coiled tubes using Eulerian two-phase turbulent model

    Science.gov (United States)

    Naphon, P.; Arisariyawong, T.; Nualboonrueng, T.

    2017-07-01

    A computation fluid dynamics study has been performed to analyze the nanofluids heat transfer and flow characteristics in the spirally coiled tubes. Eulerian two-phase turbulent model is applied to simulate the heat transfer and flow characteristics in the vertical spirally coiled tube. The spirally coiled tubes are fabricated by bending a 8.50 mm inner diameter straight copper tube into a spiral-coil with two different curvature ratios of 0.035, 0.060. The predicted results are verified with the present measured data. Reasonable agreement is obtained from the comparison between the measured data and the predicted results. In addition, due to the centrifugal force, the induced secondary flow has significant effect on the heat transfer enhancement as flowing through the spirally coiled tube. Effects of curvature, nanofluids concentration and hot water temperature on the nanofluids heat transfer characteristics and pressure drop are considered.

  13. Numerical evaluation of laminar heat transfer enhancement in nanofluid flow in coiled square tubes.

    Science.gov (United States)

    Sasmito, Agus Pulung; Kurnia, Jundika Candra; Mujumdar, Arun Sadashiv

    2011-05-09

    Convective heat transfer can be enhanced by changing flow geometry and/or by enhancing thermal conductivity of the fluid. This study proposes simultaneous passive heat transfer enhancement by combining the geometry effect utilizing nanofluids inflow in coils. The two nanofluid suspensions examined in this study are: water-Al2O3 and water-CuO. The flow behavior and heat transfer performance of these nanofluid suspensions in various configurations of coiled square tubes, e.g., conical spiral, in-plane spiral, and helical spiral, are investigated and compared with those for water flowing in a straight tube. Laminar flow of a Newtonian nanofluid in coils made of square cross section tubes is simulated using computational fluid dynamics (CFD)approach, where the nanofluid properties are treated as functions of particle volumetric concentration and temperature. The results indicate that addition of small amounts of nanoparticles up to 1% improves significantly the heat transfer performance; however, further addition tends to deteriorate heat transfer performance.

  14. Heating requirements for the BARREL toroid coil cryostat of ATLAS in case of vacuum loss

    CERN Document Server

    Vila-Nova-Goncalves, L

    2002-01-01

    The ATLAS Barrel Toroid cryostat external surface has to be heated by means of heating tapes in order to avoid air condensation in case a major vacuum leak occurs in the coil system. The present note concentrates on the evaluation of the strategies for placing the heating tapes as a basis for calculating their necessary overall length. After a brief description of the ATLAS Barrel Toroid system, the problem is described. A 2D model of a representative portion of the vacuum vessel, on which finite element studies will be performed, is then introduced. The results of the simulations and the conclusions will follow.

  15. A novel low-E field coil to minimize heating of biological samples in solid-state multinuclear NMR experiments

    Science.gov (United States)

    Dillmann, Baudouin; Elbayed, Karim; Zeiger, Heinz; Weingertner, Marie-Catherine; Piotto, Martial; Engelke, Frank

    2007-07-01

    A novel coil, called Z coil, is presented. Its function is to reduce the strong thermal effects produced by rf heating at high frequencies. The results obtained at 500 MHz in a 50 μl sample prove that the Z coil can cope with salt concentrations that are one order of magnitude higher than in traditional solenoidal coils. The evaluation of the rf field is performed by numerical analysis based on first principles and by carrying out rf field measurements. Reduction of rf heating is probed with a DMPC/DHPC membrane prepared in buffers of increasing salt concentrations. The intricate correlation that exists between the magnetic and electric field is presented. It is demonstrated that, in a multiply tuned traditional MAS coil, the rf electric field E1 cannot be reduced without altering the rf magnetic field. Since the detailed distribution differs when changing the coil geometry, a comparison involving the following three distinct designs is discussed: (1) a regular coil of 5.5 turns, (2) a variable pitch coil with the same number of turns, (3) the new Z coil structure. For each of these coils loaded with samples of different salt concentrations, the nutation fields obtained at a certain power level provide a basis to discuss the impact of the dielectric and conductive losses on the rf efficiency.

  16. A novel low-E field coil to minimize heating of biological samples in solid-state multinuclear NMR experiments.

    Science.gov (United States)

    Dillmann, Baudouin; Elbayed, Karim; Zeiger, Heinz; Weingertner, Marie-Catherine; Piotto, Martial; Engelke, Frank

    2007-07-01

    A novel coil, called Z coil, is presented. Its function is to reduce the strong thermal effects produced by rf heating at high frequencies. The results obtained at 500MHz in a 50 microl sample prove that the Z coil can cope with salt concentrations that are one order of magnitude higher than in traditional solenoidal coils. The evaluation of the rf field is performed by numerical analysis based on first principles and by carrying out rf field measurements. Reduction of rf heating is probed with a DMPC/DHPC membrane prepared in buffers of increasing salt concentrations. The intricate correlation that exists between the magnetic and electric field is presented. It is demonstrated that, in a multiply tuned traditional MAS coil, the rf electric field E(1) cannot be reduced without altering the rf magnetic field. Since the detailed distribution differs when changing the coil geometry, a comparison involving the following three distinct designs is discussed: (1) a regular coil of 5.5 turns, (2) a variable pitch coil with the same number of turns, (3) the new Z coil structure. For each of these coils loaded with samples of different salt concentrations, the nutation fields obtained at a certain power level provide a basis to discuss the impact of the dielectric and conductive losses on the rf efficiency.

  17. Heat recovery from ground below the solar pond

    NARCIS (Netherlands)

    Ganguly, S.; Date, Abhijit; Akbarzadeh, Aliakbar

    2017-01-01

    The method of heat recovery from the ground below solar ponds is investigated in the present brief note. Solar ponds lose considerable amount of heat from its bottom to the ground due to temperature gradient between them. This waste heat from ground, which is at different temperature at different

  18. Reflection of ground-source heat pump systems' application

    Institute of Scientific and Technical Information of China (English)

    ZHANGSuyun; LINZhenguo; WUXiangsheng; WUTian

    2003-01-01

    Ground-source heat pump system is an air-conditioning form of energy efficient and environment protection. This article introduced the forms of ground-source heat pump systems, analyzed the problems of ground-source heat pump systems in application in China, and put forward the solutions to these problems.

  19. A refined computer program for the transient simulation of ground coupled heat pump systems

    Science.gov (United States)

    Andrews, J. W.; Metz, P. D.; Saunders, J. H.

    1983-04-01

    The use of the earth as a heat source/sink or storage medium for various heat pump based space conditioning systems were investigated. A computer program ground coupled system (GROCS) was developed to model the behavior of ground coupling devices. The GROCS was integrated with TRNSYS, the solar system simulation program, to permit the simulation of complete ground coupled heat pump systems. Experimental results were compared to GROCS simulation results for model validation. It is found that the model has considerable validity. A refined version of the GROCS-TRNSYS program developed to model vertical or horizontal earth coil systems, which considers system cycling is described. The design of the program and its interaction with TRNSYS are discussed.

  20. Numerical and experimental study of local heat transfer enhancement in helically coiled pipes. Preliminary results.

    Science.gov (United States)

    Bozzoli, F.; Cattani, L.; Rainieri, S.; Zachár, A.

    2015-11-01

    In the last years, the attention of heat transfer equipments manufacturers turned toward helically coiled-tube heat exchangers, especially with regards to applications for viscous and/or particulate products. The recent progress achieved in numerical simulation motivated many research groups to develop numerical models for this kind of apparatuses. These models, intended both to improve the knowledge of the fundamental heat transfer mechanisms in curved geometries and to support the industrial design of this kind of apparatuses, are usually validated throughout the comparison with either theoretical or experimental evidences by considering average heat transfer performances. However, this approach doesn't guarantee that the validated models are able to reproduce local effects in details, which are so important in this kind of non-standard geometries. In the present paper a numerical model of convective heat transfer in coiled tubes for laminar flow regime was formulated and discussed. Its goodness was checked throughout the comparison with the latest experimental outcomes of Bozzoli et al. [1] in terms of convective heat flux distribution along the boundary of the duct, by ensuring the effectiveness of the model also in the description of local behaviours. Although the present paper reports only preliminary results of this simulation/validation process, it could be of interest for the research community because it proposes a novel approach that could be useful to validate many numerical models for nonstandard geometries.

  1. Effects of design parameters and puff topography on heating coil temperature and mainstream aerosols in electronic cigarettes

    Science.gov (United States)

    Zhao, Tongke; Shu, Shi; Guo, Qiuju; Zhu, Yifang

    2016-06-01

    Emissions from electronic cigarettes (ECs) may contribute to both indoor and outdoor air pollution and the number of users is increasing rapidly. ECs operate based on the evaporation of e-liquid by a high-temperature heating coil. Both puff topography and design parameters can affect this evaporation process. In this study, both mainstream aerosols and heating coil temperature were measured concurrently to study the effects of design parameters and puff topography. The heating coil temperatures and mainstream aerosols varied over a wide range across different brands and within same brand. The peak heating coil temperature and the count median diameter (CMD) of EC aerosols increased with a longer puff duration and a lower puff flow rate. The particle number concentration was positively associated with the puff duration and puff flow rate. These results provide a better understanding of how EC emissions are affected by design parameters and puff topography and emphasize the urgent need to better regulate EC products.

  2. Optimal Ground Source Heat Pump System Design

    Energy Technology Data Exchange (ETDEWEB)

    Ozbek, Metin [ENVIRON; Yavuzturk, Cy [University of Hartford; Pinder, George [University of Vermont

    2015-04-15

    Despite the facts that GSHPs first gained popularity as early as the 1940’s and they can achieve 30 to 60 percent in energy savings and carbon emission reductions relative to conventional HVAC systems, the use of geothermal energy in the U.S. has been less than 1 percent of the total energy consumption. The key barriers preventing this technically-mature technology from reaching its full commercial potential have been its high installation cost and limited consumer knowledge and trust in GSHP systems to deliver the technology in a cost-effective manner in the market place. Led by ENVIRON, with support from University Hartford and University of Vermont, the team developed and tested a software-based a decision making tool (‘OptGSHP’) for the least-cost design of ground-source heat pump (‘GSHP’) systems. OptGSHP combines state of the art optimization algorithms with GSHP-specific HVAC and groundwater flow and heat transport simulation. The particular strength of OptGSHP is in integrating heat transport due to groundwater flow into the design, which most of the GSHP designs do not get credit for and therefore are overdesigned.

  3. Optimal Ground Source Heat Pump System Design

    Energy Technology Data Exchange (ETDEWEB)

    Ozbek, Metin [Environ Holdings Inc., Princeton, NJ (United States); Yavuzturk, Cy [Univ. of Hartford, West Hartford, CT (United States); Pinder, George [Univ. of Vermont, Burlington, VT (United States)

    2015-04-01

    Despite the facts that GSHPs first gained popularity as early as the 1940’s and they can achieve 30 to 60 percent in energy savings and carbon emission reductions relative to conventional HVAC systems, the use of geothermal energy in the U.S. has been less than 1 percent of the total energy consumption. The key barriers preventing this technically-mature technology from reaching its full commercial potential have been its high installation cost and limited consumer knowledge and trust in GSHP systems to deliver the technology in a cost-effective manner in the market place. Led by ENVIRON, with support from University Hartford and University of Vermont, the team developed and tested a software-based a decision making tool (‘OptGSHP’) for the least-cost design of ground-source heat pump (‘GSHP’) systems. OptGSHP combines state of the art optimization algorithms with GSHP-specific HVAC and groundwater flow and heat transport simulation. The particular strength of OptGSHP is in integrating heat transport due to groundwater flow into the design, which most of the GSHP designs do not get credit for and therefore are overdesigned.

  4. CONDENSATION HEAT TRANSFER OF R-134A IN HORIZONTAL STRAIGHT AND HELICALLY COILED TUBE-IN-TUBE HEAT EXCHANGERS

    Institute of Scientific and Technical Information of China (English)

    2007-01-01

    This article presents an experimental investigation on condensation heat transfer of R-134a in horizontal straight and helically coiled tube-in-tube heat exchangers. The experiments were carried out at three saturation temperatures(35℃, 40℃ and 45℃) with the refrigerant mass flux varying from 100 kg/m2 s to 400 kg/m2 s and the vapor quality ranging from 0.1 to 0.8. The effects of vapor quality and mass flux of R-134a on the condensation heat transfer coefficient were investigated. The results indicate that the condensation heat transfer coefficients of the helical section are 4%-13.8% higher than that of the straight section. The experimental results were compared with the data available in literature for helical and straight pipes.

  5. A magnetic induction heating system with multi-cascaded coils and adjustable magnetic circuit for hyperthermia.

    Science.gov (United States)

    Huang, Chi-Fang; Chao, Hsuan-Yi; Chang, Hsun-Hao; Lin, Xi-Zhang

    2016-01-01

    Based on the characteristics of cancer cells that cannot survive in an environment with temperature over 42 °C, a magnetic induction heating system for cancer treatment is developed in this work. First, the methods and analyses for designing the multi-cascaded coils magnetic induction hyperthermia system are proposed, such as internal impedance measurement of power generator, impedance matching of coils, and analysis of the system. Besides, characteristics of the system are simulated by a full-wave package for engineering optimization. Furthermore, by considering the safety factor of patients, a two-sectional needle is designed for hyperthermia. Finally, this system is employed to test the liver of swine in ex-vivo experiments, and through Hematoxylin and Eosin (H&E) stain and NADPH oxidase activity assay, the feasibility of this system is verified.

  6. Numerical investigation of flow and heat transfer performances of horizontal spiral-coil pipes

    Institute of Scientific and Technical Information of China (English)

    季家东; 葛培琪; 毕文波

    2016-01-01

    The flow and heat transfer performances of horizontal spiral-coil pipes of circular and elliptical cross-sections are studied. The numerical results are compared with the experimental data, to verify the numerical method. The effects of the inlet water mass flow rate, the structural parameters, the helical pitch and the radius ratio on the heat transfer performances are investigated. Perfor- mances of the secondary fluid flow with different radius ratios are also investigated. Numerical results demonstrate that the heat transfer coefficient and the Nusselt number increase with the increase of the water mass flow rate or the helical pitch. The maximum heat transfer coefficient and the maximum Nusselt number are obtained when the radius ratio isequal to 1.00. In addition, the fluid particle moves spirally along the pipe and the velocity changes periodically. The particle flow intensity and the spiral movement frequency decrease significantly with the increase of the radius ratio. Besides, the secondary flow profile in the horizontal spiral-coil pipe contains two oppositely rotating eddies, and the eddy intensity decreases significantly along the pipe owing to the change of curvature. The decreasing tendency of the eddy intensity along the pipe increases with the increase of the radius ratio.

  7. CFD analysis of the two-phase bubbly flow characteristics in helically coiled rectangular and circular tube heat exchangers

    Science.gov (United States)

    Hussain, Alamin; Fsadni, Andrew M.

    2016-03-01

    Due to their ease of manufacture, high heat transfer efficiency and compact design, helically coiled heat exchangers are increasingly being adopted in a number of industries. The higher heat transfer efficiency over straight pipes is due to the secondary flow that develops as a result of the centrifugal force. In spite of the widespread use of helically coiled heat exchangers, and the presence of bubbly two-phase flow in a number of systems, very few studies have investigated the resultant flow characteristics. This paper will therefore present the results of CFD simulations for the two-phase bubbly flow in helically coiled heat exchangers as a function of the volumetric void fraction and the tube cross-section design. The CFD results are compared to the scarce flow visualisation experimental results available in the open literature.

  8. Heat absorbtion by earth coil systems placed in two layers in one trench. [Heat pumps]. Varmeoptagelse fra jordslanger i to lag i samme grav

    Energy Technology Data Exchange (ETDEWEB)

    Willumsen, O.

    1989-01-01

    The aim of the project is to evaluate the performance of a new technique of installing earth coil systems for heat pumps. In order to reduce the costs of an efficient heat absorber, two coils were placed in the same trench in two different levels, generally in a depth of 0.7 and 1.1 metres. Usually the total pipe length was increased with 20 - 30% compared to the one-layer design. The digging expences, however, were still smaller than those of the one-layer design. The evaluation is based on measurements on 4 heat pump installations using the two-layer concept, where the extracted heat energy from the higher and lower earth coils were metered individually on a monthly basis. Furthermore, the in- and outlet temperature of the coils and the energy comsumption of the heat pump was measured. The main conclusions of the project are: - A two-layer design leads to a slightly cheaper earth coil. The performance of the earth coil is not negatively affected by this technique, provided that the vertical distance between the coils is at least 0.4 metres at any place. - Two-layer coils may be designed with the same total length as used in one-layer coils - which means half the trench length. This design gives a more intensive exploitation of the available soil area, without decreasing the performance of the heat pump. - The disadvantage of the technique is an increasing risk of earth elevation due to freezing. This risk should be minimized by keeping a minimum distance of 0.40 meters between the individual pipes and thermal insulation if more than two pipes are placed near to each other. (AB).

  9. Domestic Hot Water Production with Ground Source Heat Pump in Apartment Buildings

    Directory of Open Access Journals (Sweden)

    Jukka Yrjölä

    2015-08-01

    Full Text Available Producing domestic hot water (DHW with a ground source heat pump (GSHP is challenging due to the high temperature (HT of DHW. There are many studies proving the better performance of cascade heat pumps compared to single-stage heat pumps when the difference between the condensing and the evaporation temperature is large. In this system approach study, different GSHP arrangements are described and computationally compared. A two-stage heat pump arrangement is introduced in which water tanks of the heating system are utilized for warming up the DHW in two stages. It is shown that the electricity consumption with this two-stage system is approximately 31% less than with the single-stage heat pump and 12% less than with the cascade system. Further, both low temperature (LT and HT heat pumps can run alone, which is not common in cascade or other two-stage heat pumps. This is advantageous because the high loads of the space heating and DHW production are not simultaneous. Proper insulation of the DHW and recirculation pipe network is essential, and drying towel rails or other heating coils should be avoided when aiming for a high efficiency. The refrigerants in the calculations are R407C for the LT heat pump and R134a for the HT heat pump. Investment costs are excluded from calculations.

  10. Heat and mass transfer analysis of a helical coil rectifier in an ammonia-water absorption system

    Energy Technology Data Exchange (ETDEWEB)

    Fernandez-Seara, Jose; Sieres, Jaime; Vazquez, Manuel [Area de Maquinas y Motores Termicos, Escuela Tecnica Superior de Ingenieros Industriales de Vigo, Campus Lagoas-Marcosende, No 9, 36200, Vigo (Spain)

    2003-08-01

    This paper presents a detailed study on the ammonia-water vapour rectification process in absorption systems using a helical coil rectifier. A differential mathematical model has been developed on the basis of mass and energy balances and heat and mass transfer equations. The differential volume has been defined in each coil turn by a differential angle on the turn and a second differential angle on the coiled tube cross section. It contains the corresponding differential portion of coolant, coiled tube wall, condensate film and vapour. Simultaneous heat and mass transfer processes have been taken into account in the vapour and liquid phases. The model equations have been solved using the finite-difference method. Results have been obtained for characteristic data from an ammonia-water absorption refrigeration system. Most significant calculated variable profiles along the coil height as well as in the coiled tube cross section are presented and discussed. The influence of the heat and mass transfer coefficients on the rectifier performance has also been considered. (authors)

  11. Ground-source Heat Pump Barometer

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2011-09-15

    The double whammy dealt by the economic crisis and housing slump has stifled expansion of the ground-source heat pump market in many European countries. The European Union market contracted for the second year running (by 2.9% between 2009 and 2010), and this despite the fact that more than 100,000 units were sold over the twelve-month period, taking the number of installed units past the one million mark. [French] La crise economique ainsi que la crise immobiliere qui touchent de nombreux pays europeens ne facilitent pas l'essor du marche de la pompe a chaleur geothermique. Pour la deuxieme annee consecutive, le marche de l'union europeenne est en baisse (-2,9 % entre 2009 et 2010). il parvient tout de meme a se maintenir au-dessus des 100 000 unites vendues par an, ce qui lui permet de depasser pour la premiere fois le cap du million d'unites installees.

  12. A novel design method for ground source heat pump

    Directory of Open Access Journals (Sweden)

    Dong Xing-Jie

    2014-01-01

    Full Text Available This paper proposes a novel design method for ground source heat pump. The ground source heat pump operation is controllable by using several parameters, such as the total meters of buried pipe, the space between wells, the thermal properties of soil, thermal resistance of the well, the initial temperature of soil, and annual dynamic load. By studying the effect of well number and well space, we conclude that with the increase of the well number, the inlet and outlet water temperatures decrease in summer and increase in winter, which enhance the efficiency of ground source heat pump. The well space slightly affects the water temperatures, but it affects the soil temperature to some extent. Also the ground source heat pump operations matching with cooling tower are investigated to achieve the thermal balance. This method greatly facilitates ground source heat pump design.

  13. Investigation of direct expansion in ground source heat pumps

    Science.gov (United States)

    Kalman, M. D.

    A fully instrumented subscale ground coupled heat pump system was developed, and built, and used to test and obtain data on three different earth heat exchanger configurations under heating conditions (ground cooling). Various refrigerant flow control and compressor protection devices were tested for their applicability to the direct expansion system. Undistributed Earth temperature data were acquired at various depths. The problem of oil return at low evaporator temperatures and low refrigerant velocities was addressed. An analysis was performed to theoretically determine what evaporator temperature can be expected with an isolated ground pipe configuration with given length, pipe size, soil conditions and constant heat load. Technical accomplishments to data are summarized.

  14. Ground coupled solar heat pumps: analysis of four options

    Energy Technology Data Exchange (ETDEWEB)

    Andrews, J.W.

    1981-01-01

    Heat pump systems which utilize both solar energy and energy withdrawn from the ground are analyzed using a simplified procedure which optimizes the solar storage temperature on a monthly basis. Four ways of introducing collected solar energy to the system are optimized and compared. These include use of actively collected thermal input to the heat pump; use of collected solar energy to heat the load directly (two different ways); and use of a passive option to reduce the effective heating load.

  15. Coil Welding Aid

    Science.gov (United States)

    Wiesenbach, W. T.; Clark, M. C.

    1983-01-01

    Positioner holds coil inside cylinder during tack welding. Welding aid spaces turns of coil inside cylinder and applies contact pressure while coil is tack-welded to cylinder. Device facilitates fabrication of heat exchangers and other structures by eliminating hand-positioning and clamping of individual coil turns.

  16. In Situ Measurement of the Undisturbed Ground Temperature for Ground Source Heat Pump System

    Institute of Scientific and Technical Information of China (English)

    ZHOU Ya-su

    2008-01-01

    The undisturbed ground are important for design of the ground heat exchangers in ground source heat pump (GSHP) systems. In this paper, the undisturbed ground temperatures measured in two different methods are presented. The investigation was carried out in two cases. The temperature measured with the direct method is assumed to give the correct undisturbed ground temperature profile. The temperature measured with indirect method overestimates the undisturbed ground temperature by 2.1℃ and 1.7℃. This difference is mainly caused by the circulation pump and ambient air to the fluid. Therefore, the results that are decreased about 2℃ as compared with the indirect measured are recommended to estimate the undisturbed ground temperature in situ measuring. A smaller pump or deeper borehole or mild weather would result in a more correct temperature. Because the undisturbed ground temperature is affected by many factors. Whether or not these conclusions are correct to other areas, this would need further investigation.

  17. Experimental investigation of TiO2/water nanofluid laminar forced convective heat transfer through helical coiled tube

    Science.gov (United States)

    Kahani, M.; Zeinali Heris, S.; Mousavi, S. M.

    2014-05-01

    Coiled tubes and nanofludics are two significant techniques to enhance the heat transfer ability of thermal equipments. The forced convective heat transfer and the pressure drop of nanofluid inside straight tube and helical coiled one with a constant wall heat flux were studied experimentally. Distilled water was used as a host fluid and Nanofluids of aqueous TiO2 nanoparticles (50 nm) suspensions were prepared in various volume concentrations of 0.25-2 %. The heat transfer coefficient of nanofluids is obtained for different nanoparticle concentrations as well as various Reynolds numbers. The experiments covered a range of Reynolds number of 500-4,500. The results show the considerable enhancement of heat transfer rate, which is due to the nanoparticles present in the fluid. Heat transfer coefficient increases by increasing the volume concentration of nanoparticles as well as Reynolds number. Moreover, due to the curvature of the tube when fluid flows inside helical coiled tube instead of straight one, both convective heat transfer coefficient and the pressure drop of fluid grow considerably. Also, the thermal performance factors for tested nanofluids are greater than unity and the maximum thermal performance factor of 3.72 is found with the use of 2.0 % volume concentration of nanofluid at Reynolds number of 1,750.

  18. Mathematical Model for Temperature Field of Strip Coil in Cooling and Heating Process

    Institute of Scientific and Technical Information of China (English)

    SUN Ji-quan; SUN Jing-hong; WU Bin; LIAN Jia-chuang

    2005-01-01

    The convection between the strip coil boundary and the surrounding medium was studied,and the math ematical model and boundary conditions for the temperature field of anisotropic strip coil was proposed,and the temperature field of strip coil were calculated by the analytic method.

  19. Heat transfer analysis of underground U-type heat exchanger of ground source heat pump system.

    Science.gov (United States)

    Pei, Guihong; Zhang, Liyin

    2016-01-01

    Ground source heat pumps is a building energy conservation technique. The underground buried pipe heat exchanging system of a ground source heat pump (GSHP) is the basis for the normal operation of an entire heat pump system. Computational-fluid-dynamics (CFD) numerical simulation software, ANSYS-FLUENT17.0 have been performed the calculations under the working conditions of a continuous and intermittent operation over 7 days on a GSHP with a single-well, single-U and double-U heat exchanger and the impact of single-U and double-U buried heat pipes on the surrounding rock-soil temperature field and the impact of intermittent operation and continuous operation on the outlet water temperature. The influence on the rock-soil temperature is approximately 13 % higher for the double-U heat exchanger than that of the single-U heat exchanger. The extracted energy of the intermittent operation is 36.44 kw·h higher than that of the continuous mode, although the running time is lower than that of continuous mode, over the course of 7 days. The thermal interference loss and quantity of heat exchanged for unit well depths at steady-state condition of 2.5 De, 3 De, 4 De, 4.5 De, 5 De, 5.5 De and 6 De of sidetube spacing are detailed in this work. The simulation results of seven working conditions are compared. It is recommended that the side-tube spacing of double-U underground pipes shall be greater than or equal to five times of outer diameter (borehole diameter: 180 mm).

  20. Ground Source Heat Pump Sub-Slab Heat Exchange Loop Performance in a Cold Climate

    Energy Technology Data Exchange (ETDEWEB)

    Mittereder, Nick [IBACOS, Inc., Pittsburgh, PA (United States); Poerschke, Andrew [IBACOS, Inc., Pittsburgh, PA (United States)

    2013-11-01

    This report presents a cold-climate project that examines an alternative approach to ground source heat pump (GSHP) ground loop design. The innovative ground loop design is an attempt to reduce the installed cost of the ground loop heat exchange portion of the system by containing the entire ground loop within the excavated location beneath the basement slab. Prior to the installation and operation of the sub-slab heat exchanger, energy modeling using TRNSYS software and concurrent design efforts were performed to determine the size and orientation of the system. One key parameter in the design is the installation of the GSHP in a low-load home, which considerably reduces the needed capacity of the ground loop heat exchanger. This report analyzes data from two cooling seasons and one heating season.

  1. Heating performance of a ground source heat pump system installed in a school building

    Institute of Scientific and Technical Information of China (English)

    Jaedo; SONG; Kwangho; LEE; Youngman; JEONG; Seongir; CHEONG; Jaekeun; LEE; Yujin; HWANG; Yeongho; LEE; Donghyuk; LEE

    2010-01-01

    The heating performance of a water-to-refrigerant type ground source heat pump system is represented in this paper under the actual working conditions of the GSHP(ground source heat pump) system during the winter season of 2008.Ten heat pump equipments with the capacity of 10 HP each and a closed vertical typed-ground heat exchanger with 24 boreholes of 175 m in depth were constructed.We investigated a variety of working conditions,including the outdoor temperature,the ground temperature,and the water temperature of inlet and outlet of the ground heat exchanger in order to examine the heating performance of the GSHP system.Subsequently,the heating capacity and the input power were investigated to determine the heating performance of the GSHP system.The average heating coefficient of performance(COP) of the heat pump was noted to be 5.1 at partial load of 47%,while the overall system COP was found to be 4.2.Also,performance of the GSHP system was compared with that of air source heat pump.

  2. Ground Source Heat Pump Sub-Slab Heat Exchange Loop Performance in a Cold Climate

    Energy Technology Data Exchange (ETDEWEB)

    Mittereder, N.; Poerschke, A.

    2013-11-01

    This report presents a cold-climate project that examines an alternative approach to ground source heat pump (GSHP) ground loop design. The innovative ground loop design is an attempt to reduce the installed cost of the ground loop heat exchange portion of the system by containing the entire ground loop within the excavated location beneath the basement slab. Prior to the installation and operation of the sub-slab heat exchanger, energy modeling using TRNSYS software and concurrent design efforts were performed to determine the size and orientation of the system. One key parameter in the design is the installation of the GSHP in a low-load home, which considerably reduces the needed capacity of the ground loop heat exchanger. This report analyzes data from two cooling seasons and one heating season. Upon completion of the monitoring phase, measurements revealed that the initial TRNSYS simulated horizontal sub-slab ground loop heat exchanger fluid temperatures and heat transfer rates differed from the measured values. To determine the cause of this discrepancy, an updated model was developed utilizing a new TRNSYS subroutine for simulating sub-slab heat exchangers. Measurements of fluid temperature, soil temperature, and heat transfer were used to validate the updated model.

  3. Application of fractional calculus in ground heat flux estimation

    Directory of Open Access Journals (Sweden)

    Protić Milan Z.

    2012-01-01

    Full Text Available Ground (soil heat flux is important physical factor primarily because of its role in surface energy balance, analysis of atmospheric boundary layer and land surface-atmosphere interaction. Direct measurement of this property is often associated with difficulties arising from need for adequate calibration of measuring devices, determination of proper depth for probes, upward water migration and accumulation below measuring plates to lack of understanding of the governing thermal processes occurring at the ground surface. In the following paper approach for inferring heat flux indirectly, from known ground surface temperature time-dependant functions, using previously developed fractional diffusion equation for ground heat conduction is elaborated. Fractional equation is solved for two, most frequently encountered harmonic surface temperature functions. Yielded results were compared with analytic solutions. Validation results indicate that solutions obtained with fractional approach closely correspond to analytic solutions with remark that former are more general, containing the term covering the transitional effect.

  4. Experimental investigation of heat transfer and pressure drop of turbulent flow inside tube with inserted helical coils

    Science.gov (United States)

    Sharafeldeen, M. A.; Berbish, N. S.; Moawed, M. A.; Ali, R. K.

    2016-08-01

    The heat transfer and pressure drop were experimentally investigated in a coiled wire inserted tube in turbulent flow regime in the range of Reynolds number of 14,400 ≤ Re ≤ 42,900. The present work aims to extend the experimental data available on wire coil inserts to cover wire diameter ratio of 0.044 ≤ e/d ≤ 0.133 and coil pitch ratio of 1 ≤ p/d ≤ 5. Uniform heat flux was applied to the external surface of the tube and air was selected as fluid. The effects of Reynolds number and wire diameter and coil pitch ratios on the Nusselt number and friction factor were studied. The enhancement efficiency and performance criteria ranges are of (46.9-82.6 %) and (100.1-128 %) within the investigated range of the different parameters, respectively. Correlations are obtained for the average Nusselt number and friction factor utilizing the present measurements within the investigated range of geometrical parameters and Re. The maximum deviation between correlated and experimental values for Nusselt number and friction factor are ±5 and ±6 %, respectively.

  5. Ground Source Geothermal District Heating and Cooling System

    Energy Technology Data Exchange (ETDEWEB)

    Lowe, James William [Ball State Univ., Muncie, IN (United States)

    2016-10-21

    Ball State University converted its campus from a coal-fired steam boiler district heating system to a ground source heat pump geothermal district system that produces simultaneously hot water for heating and chilled water for cooling. This system will include the installation of 3,600 four hundred feet deep vertical closed loop boreholes making it the largest ground source geothermal district system in the country. The boreholes will act as heat exchangers and transfer heat by virtue of the earth’s ability to maintain an average temperature of 55 degree Fahrenheit. With growing international concern for global warming and the need to reduce worldwide carbon dioxide loading of the atmosphere geothermal is poised to provide the means to help reduce carbon dioxide emissions. The shift from burning coal to utilizing ground source geothermal will increase electrical consumption but an overall decrease in energy use and reduction in carbon dioxide output will be achieved. This achievement is a result of coupling the ground source geothermal boreholes with large heat pump chiller technology. The system provides the thermodynamic means to move large amounts of energy with limited energy input. Ball State University: http://cms.bsu.edu/About/Geothermal.aspx

  6. Numerical studies of an eccentric tube-in-tube helically coiled heat exchanger for IHEP-ADS helium purification system

    CERN Document Server

    Zhang, Jianqin

    2014-01-01

    The tube-in-tube helically coiled (TTHC) heat exchanger is preferred in the purifier of IHEP-ADS helium purification system. The position of an internal tube is usually eccentric in a TTHC heat exchanger in practice, while most TTHC heat exchangers in the literature studied are concentric. In this paper, TTHC heat exchangers with different eccentricity ratios are numerically studied for turbulent flow and heat transfer characteristics under different flow rates. The fluid considered is helium at the pressure of 20Mpa, with temperature dependent thermo-physical properties for the inner tube and the annulus. The inner Nusselt number between the concentric and eccentric TTHC heat exchangers are compared, so is the annulus Nusselt number. The results show that with the eccentricity increasing, the annulus Nusselt number increases substantially. According to the numerical data, new empirical correlations of Nusselt number as a function of Reynolds number and eccentricity for the inner tube and the annulus are pres...

  7. Numerical analysis of heat exchange processes for the ground source heat pump system

    Science.gov (United States)

    Saito, H.; Muto, H.; Moritani, S.; Kohgo, Y.; Hamamoto, S.; Takemura, T.; Ohnishi, J.; Komatsu, T.

    2012-12-01

    Ground source heat pump systems (GSHP) use ground or groundwater as a heat source. They can achieve much higher coefficient of performance (COP) than conventional air source heat pump systems because the temperature of the ground is much more stable than that of the air. Heat energy in the ground is then viewed as one of the renewable energy sources. GSHP has been receiving great interests among countries in North America and Western Europe, as well as some developed countries in Asia because it can potentially reduce energy consumption and greenhouse gas emission. While GSHP can inject heat from the buildings to the ground for cooling during the summer, it can pump heat stored in the ground for heating during the winter. As some physical, chemical, and biological properties of the ground and groundwater are temperature dependent, running GSHP can eventually affect groundwater quality. The main objective of this project was to develop a model that allows predicting not only ground and groundwater temperatures but also changes in physical, chemical, and biological properties of ground and groundwater with GSHP under operations. This particular study aims at simulating heat exchange and transfer processes in the ground for a vertical-loop closed GSHP system. In the closed GSHP system, an anti-freezing solution is circulated inside the closed-loop tube, called U-tube, that is buried in the ground. Heat is then transferred to the anti-freezing solution in the U-tube by a heat exchanger. In this study we used HYDRUS to predict temperature of the anti-freezing solution, as well as that of the ground. HYDRUS allows one to simulate variably-saturated water flow and solute and heat transport in porous media numerically in two- and three-dimensional domains with great flexibility in defining boundary conditions. At first changes in anti-freezing solution temperatures measured were predicted in response to Thermal Response Test (TRT) conducted at our study site. Then, heat

  8. Starfire poloidal coil systems

    Energy Technology Data Exchange (ETDEWEB)

    Evans, K. Jr.; Kim, S.H.; Turner, L.R.; Wang, S.T.

    1980-01-01

    The poloidal coils for STARFIRE consists of three systems: (1) equilibrium field (EF) coils; (2) ohmic heating (OH) coils; and (3) correction field (CF) coils. The EF coils are superconducting and lie outside the toroidal field (TF) coils. These coils provide the bulk of the equilibrium field necessary to keep the plasma positioned in the vacuum chamber with the desired cross sectional shape and pressure and current distributions. Having these coils outside of the TF coils requires that they have a larger stored energy and larger currents but eases the assembly, maintenance, and reliability of the coils. The STARFIRE OH system is relatively small compared to tokamaks in which the current is entirely ohmically driven. It is designed to provide sufficient flux in the early startup to raise the plasma current to the point (1 to 2 MA) where the rf current drive can take over.

  9. Comparative study of heat transfer from Nb-Ti and Nb_{3}Sn coils to He II

    Directory of Open Access Journals (Sweden)

    Marco La China

    2008-08-01

    Full Text Available In superconducting magnets, the energy deposited or generated in the coil must be evacuated to prevent temperature rise and consequent transition of the superconductor to the resistive state. The main barrier to heat extraction is represented by the electric insulation wrapped around superconducting cables. In the LHC, insulation improvement is a key point in the development of interaction region magnets and injector chain fast-pulsed magnets for luminosity upgrade; the high heat load of these magnets, in fact, is not compatible with the use of current insulation schemes. We review the standard insulation schemes for Nb-Ti and Nb_{3}Sn technology from the thermal point of view. We implement, in an analytical model, the strongly nonlinear thermal resistances of the different coil components including the permeability to superfluid helium of Nb-Ti insulations, measured during the LHC main dipole development. We use such a model to compare Nb-Ti and Nb_{3}Sn technologies by taking into account their specific operating margin in different working conditions. Finally, we propose an insulation scheme to enhance the heat transfer capability of Nb-Ti coils.

  10. Heating and cooling with ground-loop heat pumps; Heizen und Kuehlen mit erdgekoppelten Waermepumpen

    Energy Technology Data Exchange (ETDEWEB)

    Afjei, Th.; Dott, R. [Institut Energie am Bau, Fachhochschule Nordwestschweiz (FHNW), Muttenz (Switzerland); Huber, A. [Huber Energietechnik AG, Zuerich (Switzerland)

    2007-08-15

    This final report for the Swiss Federal Office of Energy (SFOE) presents the results of the SFOE-project 'Heating and cooling with ground coupled heat pumps' in which the benefits and costs of a heat pump heating and cooling system with a borehole heat exchanger were examined. In particular the dimensioning of the hydraulic system, control concept and user behaviour are dealt with. The results of the simulations of thermal building behaviour with MATLAB/SIMULINK, CARNOT, and EWS are discussed. The results of parameter studies carried out, including varying shading, cooling characteristic curves, temperature differences in the heat exchanger and the dead time between heating and cooling mode are discussed. These showed that a simple system with heat pump and borehole heat exchanger for heating or preparation of domestic hot water as well as for passive cooling proved to be the best choice.

  11. Ground energy coupling

    Science.gov (United States)

    Metz, P. D.

    The feasibility of ground coupling for various heat pump systems was investigated. Analytical heat flow models were developed to approximate design ground coupling devices for use in solar heat pump space conditioning systems. A digital computer program called GROCS (GRound Coupled Systems) was written to model 3-dimensional underground heat flow in order to simulate the behavior of ground coupling experiments and to provide performance predictions which have been compared to experimental results. GROCS also has been integrated with TRNSYS. Soil thermal property and ground coupling device experiments are described. Buried tanks, serpentine earth coils in various configurations, lengths and depths, and sealed vertical wells are being investigated. An earth coil used to heat a house without use of resistance heating is described.

  12. Experimental analysis on pressure drop and heat transfer of a terminal fan-coil unit with ice slurry as cooling medium

    Energy Technology Data Exchange (ETDEWEB)

    Fernandez-Seara, Jose; Diz, Ruben; Uhia, Francisco J.; Dopazo, J. Alberto [Area de Maquinas y Motores Termicos, E.T.S. de Ingenieros Industriales, University of Vigo, Campus Lagoas-Marcosende No 9, 36310 Vigo (Spain)

    2010-09-15

    This paper is concerned with the experimental analysis of a standard terminal fan-coil unit with ice slurry as coolant. The ice slurry was produced from an ethylene glycol 10 wt% aqueous solution. The pressure drop measurements are presented as a function of volumetric flow rate, ice concentration and Reynolds number. The experimental friction factors are obtained and discussed. The fan-coil capacity was experimentally determined for chilled water and melting ice slurry with inlet ice fractions around 5, 10, 15 and 20 wt%, considering in each case three different fan rotation velocities. The fan-coil capacity is higher with melting ice slurry than with chilled water by factors between 3.7 and 4.9. The heat transfer analysis realizes that the air side thermal resistance controls the heat transfer process. Experimental results for the melt off rate of ice in the fan coil and the superheating at the fan-coil outlet are shown and discussed. (author)

  13. Covering of heating load of object by using ground heat as a renewable energy source

    Directory of Open Access Journals (Sweden)

    Čenejac Aleksandra R.

    2012-01-01

    Full Text Available Rational use of energy, improving energy performance of buildings and use of renewable energy sources are the most important measures for reducing consumption of non-renewable primary energy (solid, liquid, and gaseous fuels, environmental protection and for the future sustainable development of mankind. In the total primary energy consumption great part is related to building industry, for heating spaces in which people stay and live. Renewable energy sources (RES present natural resources and they are one of the alternatives that allow obtaining heat for heating buildings, and by that they provide a significant contribution to the energy balance of a country. This paper analyzes the participation of ground source as RES, when the vertical (the probe in the ground and horizontal (registry in the ground heat exchangers are used for covering heating load of the building.

  14. Numerical Simulation of Heat Transfer Characteristics of Horizontal Ground Heat Exchanger in Frozen Soil Layer

    Institute of Scientific and Technical Information of China (English)

    2007-01-01

    A simplified numerical model of heat transfer characteristics of horizontal ground heat exchanger (GHE) in the frozen soil layer is presented and the steady-state distribution of temperature field is simulated. Numerical results show that the frozen depth mainly depends on the soil's moisture content and ambient temperature. The heat transfer loss of horizontal GHE tends to grow with the increase of the soil's moisture content and the decrease of ambient temperature. Backfilled materials with optimal thermal conductivity can reduce the thermal loss effectively in the frozen soil. The applicability of the Chinese national standard "Technical Code for Ground Source Heat Pump (GB 50366-2005)" is verified. For a ground source heat pump project, the feasible layout of horizontal GHE should be determined based on the integration of the soil's structure, backfilled materials,weather data, and economic analysis.

  15. Optimized ground coupled heat pump design: Phase 1, Final report

    Energy Technology Data Exchange (ETDEWEB)

    Andrews, J.W.; Catan, M.; Le Doux, P.; Metz, P.D.; Saunders, J.H.

    1985-10-01

    This report describes the first phase of a project to design a water-to-air heat pump optimized for ground coupling applications. The project is being conducted jointly by Brookhaven National Laboratory (BNL), Oak Ridge National Laboratory (ORNL), and an industrial partner to be selected via a competitive procurement. In the completion of Phase I, three major tasks were completed. First, based on experimental work performed at BNL, water-refrigerant heat exchanger models were developed for incorporation into the ORNL heat pump optimization program. Next, a procedure was developed to generate correlations between heat pump entering fluid temperature and load. The correlations, called ''Source Temperature/Load Maps'', will tell the optimization program how many hours/season the heat pump will operate with any pair of values for these quantities. This report discusses these first two tasks within Phase I.

  16. Development and Demonstration of a High Efficiency, Rapid Heating, Low NOx Alternative to Conventional Heating of Round Steel Shapes, Steel Substrate (Strip) and Coil Box Transfer Bars

    Energy Technology Data Exchange (ETDEWEB)

    Kurek, Harry; Wagner, John

    2010-01-25

    Direct Flame Impingement involves the use of an array of very high-velocity flame jets impinging on a work piece to rapidly heat the work piece. The predominant mode of heat transfer is convection. Because of the locally high rate of heat transfer at the surface of the work piece, the refractory walls and exhaust gases of a DFI furnace are significantly cooler than in conventional radiant heating furnaces, resulting in high thermal efficiency and low NOx emissions. A DFI furnace is composed of a successive arrangement of heating modules through or by which the work piece is conveyed, and can be configured for square, round, flat, and curved metal shapes (e.g., billets, tubes, flat bars, and coiled bars) in single- or multi-stranded applications.

  17. Experimental and numerical examination of eddy (Foucault) currents in rotating micro-coils: Generation of heat and its impact on sample temperature.

    Science.gov (United States)

    Aguiar, Pedro M; Jacquinot, Jacques-François; Sakellariou, Dimitris

    2009-09-01

    The application of nuclear magnetic resonance (NMR) to systems of limited quantity has stimulated the use of micro-coils (diameter Foucault (eddy) currents, which generate heat. We report the first data acquired with a 4mm MACS system and spinning up to 10kHz. The need to spin faster necessitates improved methods to control heating. We propose an approximate solution to calculate the power losses (heat) from the eddy currents for a solenoidal coil, in order to provide insight into the functional dependencies of Foucault currents. Experimental tests of the dependencies reveal conditions which result in reduced sample heating and negligible temperature distributions over the sample volume.

  18. Simulation of embedded heat exchangers of solar aided ground source heat pump system

    Institute of Scientific and Technical Information of China (English)

    王芳; 郑茂余; 邵俊鹏; 李忠建

    2008-01-01

    Aimed at unbalance of soil temperature field of ground source heat pump system, solar aided energy storage system was established. In solar assisted ground-source heat pump (SAGSHP) system with soil storage, solar energy collected in three seasons was stored in the soil by vertical U type soil exchangers. The heat abstracted by the ground-source heat pump and collected by the solar collector was employed to heating. Some of the soil heat exchangers were used to store solar energy in the soil so as to be used in next winter after this heating period; and the others were used to extract cooling energy directly in the soil by circulation pump for air conditioning in summer. After that solar energy began to be stored in the soil and ended before heating period. Three dimensional dynamic numerical simulations were built for soil and soil heat exchanger through finite element method. Simulation was done in different strata month by month. Variation and restoration of soil temperature were studied. Economy and reliability of long term SAGSHP system were revealed. It can be seen that soil temperature is about 3 ℃ higher than the original one after one year’s running. It is beneficial for the system to operate for long period.

  19. Radiative Heating in MSL Entry: Comparison of Flight Heating Discrepancy to Ground Test and Predictive Models

    Science.gov (United States)

    Cruden, Brett A.; Brandis, Aaron M.; White, Todd R.; Mahzari, Milad; Bose, Deepak

    2014-01-01

    During the recent entry of the Mars Science Laboratory (MSL), the heat shield was equipped with thermocouple stacks to measure in-depth heating of the thermal protection system (TPS). When only convective heating was considered, the derived heat flux from gauges in the stagnation region was found to be underpredicted by as much as 17 W/sq cm, which is significant compared to the peak heating of 32 W/sq cm. In order to quantify the contribution of radiative heating phenomena to the discrepancy, ground tests and predictive simulations that replicated the MSL entry trajectory were performed. An analysis is carried through to assess the quality of the radiation model and the impact to stagnation line heating. The impact is shown to be significant, but does not fully explain the heating discrepancy.

  20. North Village Ground Source Heat Pump Demonstration Project

    Energy Technology Data Exchange (ETDEWEB)

    Redderson, Jeff

    2015-08-03

    This project demonstrated the feasibility of converting from a traditional direct exchange system to a ground source heat pump system on a large scale, multiple building apartment complex on a university campus. A total of ten apartment buildings were converted using vertical well fields and a ground source loop that connected the 24 apartments in each building into a common system. The system has yielded significant operational savings in both energy and maintenance and transformed the living environments of these residential buildings for our students.

  1. Energetic Efficiency Evaluation by Using GroundWater Heat Pumps

    Directory of Open Access Journals (Sweden)

    Tokar Adriana

    2012-09-01

    Full Text Available Romania has significant energy potential from renewable sources, but the potential used is much lower due to technical and functional disadvantages, to economic efficiency, the cost elements and environmental limitations. However, efforts are being made to integrate renewable energy in the national energy system. To promote and encourage private investments for renewable energy utilization, programs have been created in order to access funds needed to implement these technologies. Assessment of such investments was carried out from technical and economical point of view, by analyzing a heat pump using as heat source the solar energy from the ground.

  2. Experimental studies on pressure drop characteristics of cryogenic cross-counter flow coiled finned tube heat exchangers

    Science.gov (United States)

    Gupta, Prabhat Kumar; Kush, P. K.; Tiwari, Ashesh

    2010-04-01

    Cross-counter flow coiled finned tube heat exchangers used in medium capacity helium liquefiers/refrigerators were developed in our lab. These heat exchangers were developed using integrated low finned tubes. Experimental studies have been performed to know the pressure drop characteristics of tube side and shell side flow of these heat exchangers. All experiments were performed at room temperature in the Reynolds number range of 3000-30,000 for tube side and 25-155 for shell side. The results of present experiments indicate that available correlations for tube side can not be used for prediction of tube side pressure drop data due to complex surface formation at inner side of tube during formation of fins over the outer surface. Results also indicate that surface roughness effect becomes more pronounced as the value of di/ D m increases. New correlations based on present experimental data are proposed for predicting the friction factors for tube side and shell side.

  3. CFD analysis of heat transfer and pressure drop in helically coiled heat exchangers using Al{sub 2}O{sub 3} / water nanofluid

    Energy Technology Data Exchange (ETDEWEB)

    Kumar, P. C. Mukesh; Tamilarasan, R.; Sendihilnathan, S. [University College of Engineering Pattukkottai (India); Palanisamy, K. [M. Kumarasamy College of Engineering, Karur (India); Kumar, J. [Kalaivani College of Technology, Coimbatore (India)

    2015-02-15

    In this investigation, the heat transfer coefficient and pressure drop of a helically coiled tube heat exchanger handling Al{sub 2}O{sub 3} / water nanofluids is made by using computational fluid dynamics fluent (CFD) software package. This was done under laminar flow condition in the Dean number (De) range of 1650-2650 and the nanoparticles volume concentration of 0.1%, 0.4% and 0.8%. The effect of some important parameters such as nanoparticle volume concentration and Dean number (De) on heat transfer and pressure drop is studied. The coiled tube side Nusselt number (Nu) is found to be 30% higher than water at maximum De. The maximum pressure drop is found to be 9% higher than water. It is also found that the Nu and pressure drop significantly increase with increasing particle volume concentration and De. It is also found that the experimental friction factor increases with increasing the particle volume concentration and De. The CFD Nu and pressure drop results have been compared with the experimental and theoretical results. On comparison, it is found that the CFD simulation results show good agreement with the experimental and theoretical results. It is concluded that the CFD approach gives good prediction for heat transfer coefficient and pressure drop in a shell and helically coiled tube heat exchanger using Al{sub 2}O{sub 3} / water nanofluids. The average relative error between experimental Nu, pressure drop results and CFD results are found to be 8.5% and 9.5% respectively.

  4. Heat transfer enhancement in smooth tube with wire coil insert in laminar and transitional non-newtonian flow

    OpenAIRE

    García Pinar, Alberto; Solano Fernández, Juan Pedro; Viedma Robles, Antonio; Martínez Hernández, David Sebastián

    2010-01-01

    This work presents an experimental study on the heat transfer enhancement by means of a tube with wire-coil insert,for non-Newtonian laminar and transitional flow. The dimensionless pitch and wire diameter (based on the plain tube inner diameter) were chosen as p/D= 1 and e/D=0.09. Two pseudoplastic test fluids have been used: 1% by weight aqueous solutions of carboxymethyl cellulose (CMC) with high viscosity and medium viscosity. A wide range of flow conditions has been covered: Reynolds ...

  5. Ground-source heat pump case studies and utility programs

    Energy Technology Data Exchange (ETDEWEB)

    Lienau, P.J.; Boyd, T.L.; Rogers, R.L.

    1995-04-01

    Ground-source heat pump systems are one of the promising new energy technologies that has shown rapid increase in usage over the past ten years in the United States. These systems offer substantial benefits to consumers and utilities in energy (kWh) and demand (kW) savings. The purpose of this study was to determine what existing monitored data was available mainly from electric utilities on heat pump performance, energy savings and demand reduction for residential, school and commercial building applications. In order to verify the performance, information was collected for 253 case studies from mainly utilities throughout the United States. The case studies were compiled into a database. The database was organized into general information, system information, ground system information, system performance, and additional information. Information was developed on the status of demand-side management of ground-source heat pump programs for about 60 electric utility and rural electric cooperatives on marketing, incentive programs, barriers to market penetration, number units installed in service area, and benefits.

  6. Hourly simulation of a Ground-Coupled Heat Pump system

    Science.gov (United States)

    Naldi, C.; Zanchini, E.

    2017-01-01

    In this paper, we present a MATLAB code for the hourly simulation of a whole Ground-Coupled Heat Pump (GCHP) system, based on the g-functions previously obtained by Zanchini and Lazzari. The code applies both to on-off heat pumps and to inverter-driven ones. It is employed to analyse the effects of the inverter and of the total length of the Borehole Heat Exchanger (BHE) field on the mean seasonal COP (SCOP) and on the mean seasonal EER (SEER) of a GCHP system designed for a residential house with 6 apartments in Bologna, North-Center Italy, with dominant heating loads. A BHE field with 3 in line boreholes is considered, with length of each BHE either 75 m or 105 m. The results show that the increase of the BHE length yields a SCOP enhancement of about 7%, while the SEER remains nearly unchanged. The replacement of the on-off heat pump by an inverter-driven one yields a SCOP enhancement of about 30% and a SEER enhancement of about 50%. The results demonstrate the importance of employing inverter-driven heat pumps for GCHP systems.

  7. Comparative Study of Heat Transfer from Nb-Ti and Nb$_3$Sn coils to He II

    CERN Document Server

    La China, M

    2008-01-01

    In superconducting magnets, the energy deposited or generated in the coil must be evacuated to prevent temperature rise and consequent transition of the superconductor to the resistive state. The main barrier to heat extraction is represented by the electric insulation wrapped around superconducting cables. In the LHC, insulation improvement is a key point in the development of interaction region magnets and injector chain fast-pulsed magnets for luminosity upgrade; the high heat load of these magnets, in fact, is not compatible with the use of current insulation schemes. We review the standard insulation schemes for Nb-Ti and Nb3Sn technology from the thermal point of view. We implement, in an analytical model, the strongly nonlinear thermal resistances of the different coil components including the permeability to superfluid helium of Nb-Ti insulations, measured during the LHC main dipole development. We use such a model to compare Nb-Ti and Nb3Sn technologies by taking into account their specific operating...

  8. Application and Design of Ground Source Heat Pump in Villa Air-conditioning System%地源热泵空调系统在某别墅中的应用

    Institute of Scientific and Technical Information of China (English)

    王红霞; 崔璐

    2012-01-01

    总结了别墅地源热泵系统的形式,以工程为例,详细介绍了地源热泵+风机盘管+地板采暖+全热交换新风系统的设计。%Summarize systems of ground source heat pump used in the villa. With an engineering example, show details of ground source heat pump contains fan coil floor heating and total heat exchange of the fresh air system design.

  9. Study of thermal effectiveness and its relation with NTU in shell and helically coiled tube heat exchangers

    Directory of Open Access Journals (Sweden)

    Ashkan Alimoradi

    2017-03-01

    Full Text Available In the present study, the effect of operational and geometrical parameters on the thermal effectiveness of shell and helically coiled tube heat exchangers was investigated. Analysis was performed for the steady state. The working fluid of both sides is water, that its viscosity and thermal conductivity were assumed to be dependent on temperature. Based on the results, two correlations have been developed to predict the thermal effectiveness, for wide ranges of mass flow rates ratio, dimensionless geometrical parameters and product of Reynolds numbers. Furthermore, it was found for same values of NTU and Cr, the effectiveness is averagely 12.6% less than the effectiveness of parallel flow heat exchangers and this difference is approximately constant.

  10. Heat Transfer Enhancement in a Helically Coiled Tube with Al2O3/WATER Nanofluid Under Laminar Flow Condition

    Science.gov (United States)

    Kumar, P. C. Mukesh; Kumar, J.; Suresh, S.; Babu, K. Praveen

    2012-10-01

    In this experimental investigation, the heat transfer coefficients of a shell and helically coiled tube heat exchanger using Al2O3/water nanofluid under laminar flow condition were studied. The Al2O3 nanoparticles were characterized by X-Ray diffraction (XRD). The Al2O3/water nanofluid at 0.1%, 0.4% and 0.8% particle volume concentration were prepared by using two step method. The prepared nanofluid was characterized by scanning electron microscope (SEM). It is observed that the overall heat transfer coefficient, inner heat transfer coefficient and experimental inner Nusselt number increase while increasing particle volume concentration and increasing inner Dean number. The enhancement of overall heat transfer coefficient was found to be 7%, 16.9% and 24.2% at 0.1%, 0.4% and 0.8% Al2O3/water nanofluid respectively when compared with water. The enhancement of tube side experimental Nusselt number was found to be 17%, 22.9% and 28% at 0.1%, 0.4% and 0.8% particle volume concentration of Al2O3/water nanofluid respectively when compared with water at fixed Dean number. The tests were conducted in the range of 1600 tube.

  11. Flow pattern-based mass and heat transfer and frictional drag of gas-non-Newtonian liquid flow in helical coil: two- and three-phase systems

    Science.gov (United States)

    Thandlam, Anil Kumar; Das, Chiranjib; Majumder, Subrata Kumar

    2016-08-01

    Investigation of wall-liquid mass transfer and heat transfer phenomena with gas-Newtonian and non-Newtonian fluids in vertically helical coil reactor have been reported in this article. Experiments were conducted to investigate the effect of various dynamic and geometric parameters on mass and heat transfer coefficients in the helical coil reactor. The flow pattern-based heat and mass transfer phenomena in the helical coil reactor are highlighted at different operating conditions. The study covered a wide range of geometric parameters such as diameter of the tube (d t ), diameter of the coil (D c ), diameter of the particle (d p ), pitch difference (p/D c ) and concentrations of non-Newtonian liquid. The correlation models for the heat and mass transfer coefficient based on the flow pattern are developed which may be useful in process scale-up of the helical coil reactor for industrial application. The frictional drag coefficient was also estimated and analyzed by mass transfer phenomena based on the electrochemical method.

  12. Efficiency of Vertical Geothermal Heat Exchangers in the Ground Source Heat Pump System

    Institute of Scientific and Technical Information of China (English)

    Heyi Zeng; Nairen Diao; Zhaohong Fang

    2003-01-01

    Taking the fluid temperature distribution along the borehole depth into account, a new quasi-three-dimensional model for vertical ground heat exchangers has been established, which provides a better understanding of the heat transfer processes in the geothermal heat exchangers. On this basis the efficiency of the borehole has been defined and its analytical expression derived. Comparison with the previous two-dimensional model shows that the quasi-three-dimensional model is more rational and more accurate to depict the practical feature of the conduction of geothermal heat exchanger, and the efficiency notion can be easily used to determine the inlet and outlet temperature of the circulating fluid inside the heat exchanger.

  13. Utilization of the horizontal ground heat exchanger in the heating and cooling system of a residential building

    Directory of Open Access Journals (Sweden)

    Hanuszkiewicz-Drapała Małgorzata

    2016-03-01

    Full Text Available This paper presents the results of thermodynamic analyses of a system using a horizontal ground heat exchanger to cool a residential building in summer and heat it in the autumn-winter period. The main heating device is a vapour compression heat pump with the ground as the lower heat source. The aim of the analyses is to examine the impact of heat supply to the ground in the summer period, when the building is cooled, on the operation of the heating system equipped with a heat pump in the next heating season, including electricity consumption. The processes occurring in cooling and heating systems have an unsteady nature. The main results of the calculations are among others the time-dependent values of heat fluxes extracted from or transferred to the ground heat exchanger, the fluxes of heat generated by the heat pump and supplied to the heated building by an additional heat source, the parameters in characteristic points of the systems, the temperature distributions in the ground and the driving electricity consumption in the period under analysis. The paper presents results of analysis of cumulative primary energy consumption of the analyzed systems and cumulative emissions of harmful substances.

  14. Utilization of the horizontal ground heat exchanger in the heating and cooling system of a residential building

    Science.gov (United States)

    Hanuszkiewicz-Drapała, Małgorzata; Bury, Tomasz

    2016-03-01

    This paper presents the results of thermodynamic analyses of a system using a horizontal ground heat exchanger to cool a residential building in summer and heat it in the autumn-winter period. The main heating device is a vapour compression heat pump with the ground as the lower heat source. The aim of the analyses is to examine the impact of heat supply to the ground in the summer period, when the building is cooled, on the operation of the heating system equipped with a heat pump in the next heating season, including electricity consumption. The processes occurring in cooling and heating systems have an unsteady nature. The main results of the calculations are among others the time-dependent values of heat fluxes extracted from or transferred to the ground heat exchanger, the fluxes of heat generated by the heat pump and supplied to the heated building by an additional heat source, the parameters in characteristic points of the systems, the temperature distributions in the ground and the driving electricity consumption in the period under analysis. The paper presents results of analysis of cumulative primary energy consumption of the analyzed systems and cumulative emissions of harmful substances.

  15. Combined operation of two ground transmitters for enhanced ionospheric heating

    Science.gov (United States)

    Lee, M. C.; Groves, K. M.; Liao, C. P.; Rivas, D. R.; Kuo, S. P.

    1988-01-01

    The combined operation of a high or medium frequency ground transmitter and a VLF transmitter for enhanced ionospheric heating is examined. The high or medium frequency transmitter operating in a pulsed mode produce short-scale density striations that can render the nonlinear mode conversion of the subsequently launched VLF waves into lower hybrid waves. Also if the VLF waves are intense enough, they can excite meter-scale density striations and lower hybrid waves via parametric instabilities. The expected ionospheric effects of the system are discussed.

  16. An experimental study on the thermal and fouling characteristics in a washable shell and helically coiled heat exchanger by the Wilson plot method

    Energy Technology Data Exchange (ETDEWEB)

    Koo, Kyoung Min; Ahn, Young Chull [Pusan National University, Busan (Korea, Republic of); Hwang, Jun Hyeon; Hur, Hyun; Na, Byung Chul; Hwang, Yoon Jae; Kim, Byung Soon [LG Electronics, Changwon (Korea, Republic of); Lee, Jae Keun [EcoEnergy Research Institute, Busan (Korea, Republic of)

    2016-06-15

    Brazed plate heat exchangers (BPHEX) are broadly used in water source heat pump systems for their large heat transfer capacity. Despite their high heat transfer rate, their high-performance rate tends to decrease sharply, due to fouling and they cannot be cleaned. So the thermal and fouling resistances of washable Shell and helically coiled tube heat exchangers (SCHEX) are designed and experimentally investigated in this study. Heat exchangers with two different tube types are studied and compared with a brazed plate heat exchanger. The overall thermal resistance coefficient of the heat exchangers as determined by using Wilson plots is 38% lower than that of the brazed plate heat exchanger at a Reynolds number of 2460. Fouling test results revealed that regular maintenance and physical cleaning can be used to maintain the thermal resistance of fouling of the washable heat exchanger at a level equal to or less than that of the brazed plate heat exchanger.

  17. Numerical characterization of heat transfer in closed-loop vertical ground heat exchanger

    Institute of Scientific and Technical Information of China (English)

    Chulho; LEE; Hujeong; GIL; Hangseok; CHOI; Shin-Hyung; KANG

    2010-01-01

    A series of numerical analyses has been performed on the characteristics of heat transfer in a closed-loop vertical ground heat exchanger(U-loop).A 2-D finite element analysis was conducted to evaluate the temperature distribution over the cross section of the U-loop system involving high-density polyethylene(HDPE) pipe/grout/soil to compare the sectional efficiency between the conventional U-loop and a new latticed HDPE pipe system,which is equipped with a thermally insulating lattice in order to reduce thermal interference between the inlet and outlet pipes.In addition,a 3-D finite volume analysis(FLUENT) was adopted to simulate the operation of the closed-loop vertical ground heat exchanger with the consideration of the effect of a distance between the inlet and outlet pipes,grout’s thermal properties,the effectiveness of the latticed HDPE pipe system,and the rate of circulation pump.It was observed that the thermal interference between the two strands of U-loop is of importance in enhancing efficiency of the ground heat exchanger.Consequently,it is recommended to modify the configuration of the conventional U-loop system by equipping the thermally insulating lattice between the two pipe strands.

  18. Investigation of the Dynamic Melting Process in a Thermal Energy Storage Unit Using a Helical Coil Heat Exchanger

    Directory of Open Access Journals (Sweden)

    Xun Yang

    2017-08-01

    Full Text Available In this study, the dynamic melting process of the phase change material (PCM in a vertical cylindrical tube-in-tank thermal energy storage (TES unit was investigated through numerical simulations and experimental measurements. To ensure good heat exchange performance, a concentric helical coil was inserted into the TES unit to pipe the heat transfer fluid (HTF. A numerical model using the computational fluid dynamics (CFD approach was developed based on the enthalpy-porosity method to simulate the unsteady melting process including temperature and liquid fraction variations. Temperature measurements using evenly spaced thermocouples were conducted, and the temperature variation at three locations inside the TES unit was recorded. The effects of the HTF inlet parameters were investigated by parametric studies with different temperatures and flow rate values. Reasonably good agreement was achieved between the numerical prediction and the temperature measurement, which confirmed the numerical simulation accuracy. The numerical results showed the significance of buoyancy effect for the dynamic melting process. The system TES performance was very sensitive to the HTF inlet temperature. By contrast, no apparent influences can be found when changing the HTF flow rates. This study provides a comprehensive solution to investigate the heat exchange process of the TES system using PCM.

  19. Comparative Calculation of Heat Exchange with the Ground in Residential Building Including Periodes of Heat Waves

    Directory of Open Access Journals (Sweden)

    Staszczuk Anna

    2016-06-01

    Full Text Available The paper provides verification of 3D transient ground-coupled model to calculation of heat exchange between ground and typical one-storey, passive residential building. The model was performed with computer software WUFI®plus and carried out to estimate the indoor air temperatures during extending hot weather periods. For verifying the results of calculations performed by the WUFI®plus software, the most recent version of EnergyPlus software version was used. Comparison analysis of calculation results obtained with the two above mentioned calculation method was made for two scenarios of slab on ground constructions: without thermal insulation and with thermal insulation under the whole slab area. Comprehensive statistical analysis was done including time series analysis and descriptive statistics parameters.

  20. Ground Source Integrated Heat Pump (GS-IHP) Development

    Energy Technology Data Exchange (ETDEWEB)

    Baxter, V. D. [ORNL; Rice, K. [ORNL; Murphy, R. [ORNL; Munk, J. [ORNL; Ally, Moonis [ORNL; Shen, Bo [ORNL; Craddick, William [ORNL; Hearn, Shawn A. [ClimateMaster, Inc.

    2013-05-24

    Between October 2008 and May 2013 ORNL and ClimateMaster, Inc. (CM) engaged in a Cooperative Research and Development Agreement (CRADA) to develop a groundsource integrated heat pump (GS-IHP) system for the US residential market. A initial prototype was designed and fabricated, lab-tested, and modeled in TRNSYS (SOLAR Energy Laboratory, et al, 2010) to predict annual performance relative to 1) a baseline suite of equipment meeting minimum efficiency standards in effect in 2006 (combination of air-source heat pump (ASHP) and resistance water heater) and 2) a state-of-the-art (SOA) two-capacity ground-source heat pump with desuperheater water heater (WH) option (GSHPwDS). Predicted total annual energy savings, while providing space conditioning and water heating for a 2600 ft{sup 2} (242 m{sup 2}) house at 5 U.S. locations, ranged from 52 to 59%, averaging 55%, relative to the minimum efficiency suite. Predicted energy use for water heating was reduced 68 to 78% relative to resistance WH. Predicted total annual savings for the GSHPwDS relative to the same baseline averaged 22.6% with water heating energy use reduced by 10 to 30% from desuperheater contributions. The 1st generation (or alpha) prototype design for the GS-IHP was finalized in 2010 and field test samples were fabricated for testing by CM and by ORNL. Two of the alpha units were installed in 3700 ft{sup 2} (345 m{sup 2}) houses at the ZEBRAlliance site in Oak Ridge and field tested during 2011. Based on the steady-state performance demonstrated by the GS-IHPs it was projected that it would achieve >52% energy savings relative to the minimum efficiency suite at this specific site. A number of operational issues with the alpha units were identified indicating design changes needed to the system before market introduction could be accomplished. These were communicated to CM throughout the field test period. Based on the alpha unit test results and the diagnostic information coming from the field test

  1. Ground-Source Integrated Heat Pump for Near-Zero Energy Houses: Technology Status Report

    Energy Technology Data Exchange (ETDEWEB)

    Murphy, Richard W [ORNL; Rice, C Keith [ORNL; Baxter, Van D [ORNL; Craddick, William G [ORNL

    2007-09-01

    . With the greater energy savings the cost of the more energy efficient components required for the IHP can be recovered more quickly than if they were applied to individual pieces of equipment to meet each individual energy service need. An IHP can be designed to use either outdoor air or geothermal resources (e.g., ground, ground water, surface water) as the environmental energy source/sink. Based on a scoping study of a wide variety of possible approaches to meeting the energy service needs for a ZEH, DOE selected the IHP concept as the most promising and has supported research directed toward the development of both air- and ground-source versions. This report describes the ground-source IHP (GS-IHP) design and includes the lessons learned and best practices revealed by the research and development (R&D) effort throughout. Salient features of the GS-IHP include a variable-speed rotary compressor incorporating a brushless direct current permanent magnet motor which provides all refrigerant compression, a variable-speed fan for the indoor section, a multiple-speed ground coil circuit pump, and a single-speed pump for water heating operation. Laboratory IHP testing has thus far used R-22 because of the availability of the needed components that use this refrigerant. It is expected that HFC R-410A will be used for any products arising from the IHP concept. Data for a variable-speed compressor that uses R-410A has been incorporated into the DOE/ORNL Mark VI Heat Pump Design Model (HPDM). HPDM was then linked to TRNSYS, a time-series-dependent simulation model capable of determining the energy use of building cooling and heating equipment as applied to a defined house on a sub-hourly basis. This provided a highly flexible design analysis capability for advanced heat pump equipment; however, the program also took a relatively long time to run. This approach was used with the initial prototype design reported in Murphy et al. (2007a) and in the business case analysis of

  2. Heat Transmission of Slab-on-Ground Industrial Floors with Vertical Perimeter Insulation

    OpenAIRE

    Kocsis, Lajos

    2013-01-01

    The surface heat loss of slab-on-ground industrial floors that are vertically insulated along the footing wall (with the insulation reaching under the ground level), is closely linked with the relatively large floor area of industrial halls. To give a comprehensive heat transmission analysis, the present paper first provides an overview of the U-value requirements for such floors in Hungary and Germany. For the determination of the heat transmission coefficient of slab-on-ground floors with v...

  3. Study on eruption of heat for Escherichia coil B aroused by lanthanum nitrate and its mechanism

    Institute of Scientific and Technical Information of China (English)

    Guosheng LIU; Zhilin RAN; Hailei WANG; Yi LIU; Ping SHEN; Yan LU

    2008-01-01

    Biological effect of rare-earth lanthanum nitrate on the growth of Escherichia coli B was studied using the calorimetric method. There were exceptional changes on the growth thermogenic curves for high concentrations of lanthanum nitrate. For example, the peak high, the total quantity of heat (Q) of cultures and the growth rate constants (k) are evidently increased when compared with normal E. Coli B cultures. When the concentration of lanthanum nitrate was at 300 mg/L and 500 rag/L, the Q of the cultures reached 3.89 and 2.54 times of normal cultures, respectively. The survivability of cells and the biomass of the cultures were measured using biological methods and the results show that the growth and multiplication of cells were inhibited and that the biomass decreased at high concentration of lanthanum nitrate. These revealed that the inhibiting cells discharged more quantity of heat than the normal growing cells. We named this phenomenon as "eruption of heat". It was suggested that the mechanism for the eruption of heat was that La3+ ion damages the outer cell membrane and increases its permeability and the proton-electron poten-tial energy across the cell membrane was reduced or couldn't even be initiated. Energy could not be translated into ATP effectively in the course of oxidative phosphor-ylation resulting in heat release. So, the growth of the cells was inhibited due to scarceness of energy ATP.

  4. Computer simulation of ground coupled storage in a series solar assisted heat pump system

    Energy Technology Data Exchange (ETDEWEB)

    Andrews, John W.; Metz, Philip D.

    1979-01-01

    A quantitative study of the effect of thermal coupling between the ground and the heat storage element of a series solar assisted heat pump system is presented. The transient simulation computer program TRNSYS is used to simulate the solar portion of this system. A program to simulate the thermal interaction of the storage element with the ground is incorporated into TRNSYS as a sub-routine. This program calculates heat flow through the ground in discrete steps over space and time. Boundary conditions are established. The ground coupled storage is driven by thermal inputs from the solar portion of the system and from the changing ambient and ground temperatures.

  5. Ground-Coupled Heating-Cooling Systems in Urban Areas: How Sustainable Are They?

    Science.gov (United States)

    Younger, Paul L.

    2008-01-01

    Ground-coupled heating-cooling systems (GCHCSs) exchange heat between the built environment and the subsurface using pipework buried in trenches or boreholes. If heat pumps in GCHCSs are powered by "green electricity," they offer genuine carbon-free heating-cooling; for this reason, there has been a surge in the technology in recent years.…

  6. Ground-Coupled Heating-Cooling Systems in Urban Areas: How Sustainable Are They?

    Science.gov (United States)

    Younger, Paul L.

    2008-01-01

    Ground-coupled heating-cooling systems (GCHCSs) exchange heat between the built environment and the subsurface using pipework buried in trenches or boreholes. If heat pumps in GCHCSs are powered by "green electricity," they offer genuine carbon-free heating-cooling; for this reason, there has been a surge in the technology in recent…

  7. 关于《干盘管换热器与湿盘管换热器热工性能试验研究》的几点疑问%Discussion on Experiment on Thermal Performance of Dry Coil Heat Exchanger and Wet Coil Heat Exchanger

    Institute of Scientific and Technical Information of China (English)

    周岸勋

    2012-01-01

    According to the prototype construction description of dry coil heat exchanger and wet coil heat exchanger experimental prototype with the same section size and the metal consumption respectively designed under standard working condition, the formula fitted from the thermal performance test data, the definition of dry working condition, the supply water temperature of dry coil and the analysis of experimental data in Experiment on Thermal Performance of Dry Coil Heat Exchanger and Wet Coil Heat Exchanger, some different views are put forward.%针对《干盘管换热器与湿盘管换热器热工性能试验研究》中按照标准规定的标准工况,分别设计出的断面尺寸和金属耗量相同的干、湿盘管换热器试验样机的构造描述、样机热工性能试验数据的拟合公式、干工况界定、干盘管供水温度以及试验数据分析等提出一些不同观点.

  8. Experimental investigation of melting behavior of PCM by using coil heat source inside cylindrical container

    Directory of Open Access Journals (Sweden)

    M. Tayssir

    2017-05-01

    Experiments were performed for different inlet temperatures of HTF 70 °C, 80 °C and 90 °C and for different volume flow rates 5 lpm, 10 lpm and 15 lpm. The transient variation of the molten fraction, the percentage of thermal energy storage and the average Nusselt number are obtained. A significant effect of the inlet HTF temperature more than that of volume flow rate on the paraffin melting process is observed. Also, empirical correlation for the molten fraction and percentage of heat stored are deduced in terms of the operating conditions.

  9. Temperature and Humidity Independent Control Research on Ground Source Heat Pump Air Conditioning System

    Science.gov (United States)

    Chen, G.; Wang, L. L.

    Taking green demonstration center building air conditioning system as an example, this paper presents the temperature and humidity independent control system combined with ground source heat pump system, emphasis on the design of dry terminal device system, fresh air system and ground source heat pump system.

  10. Heat transfer enhancement and pressure drop analysis in a helically coiled tube using Al{sub 2}O{sub 3} / water nanofluid

    Energy Technology Data Exchange (ETDEWEB)

    Kumar, P. C. Mukesh; Tamilarasan, R.; Nathan, S. Sendhil [University College of Engineering Pattukkottai, Rajamadam (India); Kumar, J. [Sasurie College of Engineering, Tiruppur (India); Suresh, S. [National Institute of Technology, Tiruchirappalli (India)

    2014-05-15

    In this experimental investigation, the heat transfer and pressure drop analysis of a shell and helically coiled tube heat exchanger by using Al{sub 2}O{sub 3} / water nanofluids have been carried out under turbulent flow condition. The Al{sub 2}O{sub 3} / water nanofluids of 0.1%, 0.4%, and 0.8% particle volume concentration have been prepared by using two step method. The tube side experimental Nusselt number of 0.1%, 0.4% and 0.8% nanofluids were found to be 28%, 36% and 56%, respectively higher than water. These enhancements are due to higher thermal conductivity of nanofluid, better fluid mixing and strong secondary flow formation in coiled tube. The pressure drop of 0.1%, 0.4% and 0.8% were found to be 4%, 6%, and 9%, respectively higher than water. The increase in pressure drop is due to increase in nanofluid viscosity while adding nanoparticles. The measurement of nanofluid thermal performance factor is found to be greater than unity. It is concluded that the Al{sub 2}O{sub 3} nanofluid can be applied as a coolant in helically coiled tube heat exchanger to enhance heat transfer with negligible pressure drop.

  11. Comparative Study of Shell and Helically-Coiled Tube Heat Exchangers with Various Dimple Arrangements in Condensers for Odor Control in a Pyrolysis System

    Directory of Open Access Journals (Sweden)

    Sun-Min Kim

    2016-12-01

    Full Text Available This study performed evaluations of the shell and helically-coiled tube heat exchangers with various dimple arrangements, that is, flat, inline, staggered, and bulged, at different Dean numbers (De and inlet temperatures of a hot channel. Conjugated heat transfer was analyzed to evaluate the heat transfer performance of the exchangers through temperature difference between the inlet and outlet, Nusselt number inside the coiled tube, and pressure drop of the coiled tube by using 3-D Reynolds-averaged Navier–Stokes (RANS equations with shear stress transport turbulence closure. A grid dependency test was performed to determine the optimal number of the grid system. The numerical results were validated using the experimental data, and showed good agreement. The inline and staggered arrangements show the highest temperature differences through all De. The staggered arrangement shows the best heat transfer performance, whereas the inline arrangement shows the second highest performance with all ranges of De and the hot channel’s inlet temperature. The inline and staggered arrangements show the highest pressure drop among all inlet temperatures of the hot channel.

  12. Innovative commercial ``ground source'' heat pump system sources and sinks: Engineering and economics

    Energy Technology Data Exchange (ETDEWEB)

    Sachs, H.M.; Lowenstein, A.I.; Henderson, H.I. Jr.; Carlson, S.W.; Risser, J.E.

    1998-07-01

    Geothermal heat pumps, which will be called GX systems in this paper, have been employed in specialty applications on both residential and commercial buildings for several decades. GX systems generally have very competitive life cycle costs, but somewhat higher initial costs. The incremental cost of the ground heat exchanger cost is close to the average cost per ton, so GX systems work best with very efficient building shells. Innovative methods can reduce the ground heat exchanger cost. These include better coupling of the heat exchange boreholes to the ground, hybrid systems that use low cost closed fluid coolers to supplement the ground heat exchanger where cooling loads dominate, open loop systems, and opportunistic systems that use sewage effluent or other non-standard sources for heat exchange. These approaches and their benefits are illustrated through five case studies.

  13. Ground water heat pumps and cooling with ground water basins as seasonal storage; Grundvandsvarmepumper og -koeling med grundvandsmagasiner som saesonlager

    Energy Technology Data Exchange (ETDEWEB)

    2008-04-15

    Ground water temperature is constant all the year round, in Denmark approximately 9 deg. C, which is ideal for a number of cooling purposes including cooling of buildings. The structures in which the ground water flows (sand, gravel and chalk) are efficient for storing coldness and heat over longer periods. By using seasonal storage of low-temperature heat and coldness in ground water layers close to the terrain it is feasible to reach profitable energy savings of up to 90% for cooling and heating of e.g. hotels, airports, shopping malls, office buildings and other larger buildings. At the same time the large energy savings means major reduction of CO{sub 2} emissions. (BA)

  14. Ground water heat pumps and cooling with ground water basins as seasonal storage; Grundvandsvarmepumper og -koeling med grundvandsmagasiner som saesonlager

    Energy Technology Data Exchange (ETDEWEB)

    2008-04-15

    Ground water temperature is constant all the year round, in Denmark approximately 9 deg. C, which is ideal for a number of cooling purposes including cooling of buildings. The structures in which the ground water flows (sand, gravel and chalk) are efficient for storing coldness and heat over longer periods. By using seasonal storage of low-temperature heat and coldness in ground water layers close to the terrain it is feasible to reach profitable energy savings of up to 90% for cooling and heating of e.g. hotels, airports, shopping malls, office buildings and other larger buildings. At the same time the large energy savings means major reduction of CO{sub 2} emissions. (BA)

  15. Energy well. Ground-source heat in one-family houses; Energiakaivo. Maalaemmoen hyoedyntaeminen pientaloissa

    Energy Technology Data Exchange (ETDEWEB)

    Juvonen, J.; Lapinlampi, T.

    2013-08-15

    This guide deals with the legislation, planning, building, usage and maintenance of ground-source heat systems. The guide gives recommendations and instructions on national level on the permit practices and how to carry out the whole ground-source heat system project. The main focus of the guide is on energy wells for one-family houses. The principle is that an action permit is needed to build a ground-source heat system. On ground water areas a permit according to the water act may also be required. To avoid any problems, the placement of the system needs to be planned precisely. This guide gives a comprehension to the orderer on the issues that need to be considered before ordering, during construction, when the system is running and when giving up the use of the ground-source heat system. (orig.)

  16. α/β coiled coils.

    Science.gov (United States)

    Hartmann, Marcus D; Mendler, Claudia T; Bassler, Jens; Karamichali, Ioanna; Ridderbusch, Oswin; Lupas, Andrei N; Hernandez Alvarez, Birte

    2016-01-15

    Coiled coils are the best-understood protein fold, as their backbone structure can uniquely be described by parametric equations. This level of understanding has allowed their manipulation in unprecedented detail. They do not seem a likely source of surprises, yet we describe here the unexpected formation of a new type of fiber by the simple insertion of two or six residues into the underlying heptad repeat of a parallel, trimeric coiled coil. These insertions strain the supercoil to the breaking point, causing the local formation of short β-strands, which move the path of the chain by 120° around the trimer axis. The result is an α/β coiled coil, which retains only one backbone hydrogen bond per repeat unit from the parent coiled coil. Our results show that a substantially novel backbone structure is possible within the allowed regions of the Ramachandran space with only minor mutations to a known fold.

  17. Quantifying Systemic Efficiency using Exergy and Energy Analysis for Ground Source Heat Pumps: Domestic Space Conditioning and Water Heating Applications.

    Energy Technology Data Exchange (ETDEWEB)

    Ally, Moonis Raza [ORNL; Baxter, Van D [ORNL; Gehl, Anthony C [ORNL; Munk, Jeffrey D [ORNL

    2017-01-01

    Although air temperatures over land surfaces show wide seasonal and daily variations, the ground, approximately 10 meters below the earth s surface, remains relatively stable in temperature thereby serving as an energy source or sink. Ground source heat pumps can heat, cool, and supply homes with hot water efficiently by utilizing the earth s renewable and essentially inexhaustible energy resources, saving fossil fuels, reducing greenhouse gas emissions, and lowering the environmental footprint. In this paper, evidence is shown that ground source heat pumps can provide up to 79%-87% of domestic hot water energy needs, and up to 77% of space heating needs with the ground s thermal energy resources. The case refers to a 12-month study conducted at a 253 m2 research house located in Oak Ridge, Tennessee, 36.01 N 84.26 W in a mixed-humid climate with HDD of 2218 C-days and CDD of 723 C-days under simulated occupancy conditions. A single 94.5m vertical bore interfaced the heat pump with the ground. The research shows that this technology is capable of achieving US DOE targets of 25 % and 35% energy savings in HVAC, and in water heating, respectively by 2030. It is also a viable technology to meet greenhouse gas target emissions under the IECC 2012 Standard, as well as the European Union (EU) 2020 targets of using renewable energy resources. The paper quantifies systemic efficiencies using Exergy analysis of the major components, clearly pointing areas for further improvement.

  18. The Heat Exchanger Performance of Shell and Multi Tube Helical Coil as a Heater through the Utilization of a Diesel Machine’s Exhaust Gas

    Directory of Open Access Journals (Sweden)

    . Zainuddin

    2016-04-01

    Full Text Available A review on reutilization of heat waste from a diesel machine is absolutely important. This is because the exhaust gas potential of a Diesel machine keeps increasing and not much has been utilized by the industry. One of the techniques of reutilizing the heat waste in industry is by using a heat exchanger. The technique is also very useful for the environment because it can reduce air pollution caused by the exhaust gas of the diesel machine. The main purpose of the research is to find out the capability of shell and multi-tube helical coil HE as an air heater by utilizing the exhaust gas of the Diesel machine. The heat exchanger of shell and multi-tube helical coil  utilizes the exhaust thermal gas of the Diesel machine as the air heater already made. The apparatus has the following dimension: the shell length of 1.05 m, diameter 0.1524 m, tube length of 3.25 m with 20 coils, tube diameter of 0.011 m, coil diameter of 0.0508 m with 4 helical coils. The type of Diesel machine to use in the testing is 4FB1 Isuzu Diesel engine. The machine has the maximum machine power and rotation of 54 kW and 3,600 rpm. The performance testing of heat exchanger has been conducted in some variations of Diesel machine rotations of 1,500 rpm, 1,750 rpm, 2,000 rpm, 2,250 rpm and 2,500 rpm. The testing result shows a maximum effectiveness to happen at the machine rotation of 1,500 rpm. The maximum effectiveness to get is 67.8% and then it goes down drastically in accordance with the increase of air mass flow rate. The hot air temperature created is from 47.1°C to 52.3°C so that it can be used for the purpose of drying up the unhulled rice.

  19. Zoning of the territory of Russia by the effectiveness of low-potential heat of the ground and atmospheric air for heating buildings

    Science.gov (United States)

    Vasilyev, G. P.; Kolesova, M. V.; Gornov, V. F.; Yurchenko, I. A.

    2016-06-01

    The article represents the results of researches to zone the territory of Russia and Europe division into districts of by efficiency of using for the heat supply of buildings of low-potential thermal energy of ground and free air and their combination. While modeling the heat regime of geothermal HPS in climatic conditions of different regions of the territory of Russia, the influence of the long-term extraction of geothermal heat energy on the ground heat regime has been taken into account as well as the influence of phase transitions of pore moisture in ground on the efficiency of operation of geothermal heat-pump heat-supply systems. Also considered were the sinking of temperatures of ground massif by long-term extraction of the heat energy from the ground as calculation parameters of the heat energy from the ground, and as calculation parameters of ground massif temperatures.

  20. Federal Technology Alert: Ground-Source Heat Pumps Applied to Federal Facilities--Second Edition

    Energy Technology Data Exchange (ETDEWEB)

    Hadley, Donald L.

    2001-03-01

    This Federal Technology Alert, which was sponsored by the U.S. Department of Energy's Office of Federal Energy Management Programs, provides the detailed information and procedures that a Federal energy manager needs to evaluate most ground-source heat pump applications. This report updates an earlier report on ground-source heat pumps that was published in September 1995. In the current report, general benefits of this technology to the Federal sector are described, as are ground-source heat pump operation, system types, design variations, energy savings, and other benefits. In addition, information on current manufacturers, technology users, and references for further reading are provided.

  1. Simulation and optimisation of a ground source heat pump with different ground heat exchanger configurations for a single-family residential house

    DEFF Research Database (Denmark)

    Pavlov, Georgi Krasimiroy; Olesen, Bjarne W.

    2012-01-01

    In the future there will be an increased demand for energy efficient cooling of residential buildings. Therefore it is essential to develop cooling concepts that are passive and/or using very little primary energy. A possible solution is a ground source heat pump combined with a low....... For the studied geographical location, passive cooling by bypassing the heat pump and using only the ground heat exchanger can provide acceptable room temperatures.......-temperature heating and high-temperature cooling system. The present work evaluates the performance in relation to thermal comfort and energy consumption of a GSHP with different GHE concepts. The different configurations are analyzed being part of the energy supply system of a low-energy residential house...

  2. IMPACT OF GEOTHERMAL GRADIENT ON GROUND SOURCE HEAT PUMP SYSTEM MODELING

    Directory of Open Access Journals (Sweden)

    Tomislav Kurevija

    2014-07-01

    Full Text Available ndisturbed ground temperature is one of the most crucial thermogeological parameters needed for shallow geothermal resources assessment. Energy considered to be geothermal is energy stored in the ground at depths where solar radiation has no effect. At depth where undisturbed ground temperature occurs there is no influence of seasonal variations in air temperature from surface. Exact temperature value, and depth where it occurs, is functionally dependent on surface climate parameters and thermogeologic properties of ground. After abovementioned depth, increase of ground temperature is solely dependent on geothermal gradient. Accurately determined value of undisturbed ground temperature is beneficial for proper sizing of borehole heat exchangers. On practical example of building which is being heated and cooled with shallow geothermal resource, influences of undisturbed ground temperature and geothermal gradient, on size of borehole heat exchanger are going to be presented. Sizing of borehole heat exchanger was calculated with commercial software Ground Loop Designer (GLD, which uses modified line source and cylinder source solutions of heat conduction in solids.

  3. Minimax Current Density Coil Design

    CERN Document Server

    Poole, Michael; Lopez, Hector Sanchez; Ng, Michael; Crozier, Stuart; 10.1088/0022-3727/43/9/095001

    2010-01-01

    'Coil design' is an inverse problem in which arrangements of wire are designed to generate a prescribed magnetic field when energized with electric current. The design of gradient and shim coils for magnetic resonance imaging (MRI) are important examples of coil design. The magnetic fields that these coils generate are usually required to be both strong and accurate. Other electromagnetic properties of the coils, such as inductance, may be considered in the design process, which becomes an optimization problem. The maximum current density is additionally optimized in this work and the resultant coils are investigated for performance and practicality. Coils with minimax current density were found to exhibit maximally spread wires and may help disperse localized regions of Joule heating. They also produce the highest possible magnetic field strength per unit current for any given surface and wire size. Three different flavours of boundary element method that employ different basis functions (triangular elements...

  4. Ground heat flux and power sources of low-enthalpy geothermal systems

    Science.gov (United States)

    Bayer, Peter; Blum, Philipp; Rivera, Jaime A.

    2015-04-01

    Geothermal heat pumps commonly extract energy from the shallow ground at depths as low as approximately 400 m. Vertical borehole heat exchangers are often applied, which are seasonally operated for decades. During this lifetime, thermal anomalies are induced in the ground and surface-near aquifers, which often grow over the years and which alleviate the overall performance of the geothermal system. As basis for prediction and control of the evolving energy imbalance in the ground, focus is typically set on the ground temperatures. This is reflected in regulative temperature thresholds, and in temperature trends, which serve as indicators for renewability and sustainability. In our work, we examine the fundamental heat flux and power sources, as well as their temporal and spatial variability during geothermal heat pump operation. The underlying rationale is that for control of ground temperature evolution, knowledge of the primary heat sources is fundamental. This insight is also important to judge the validity of simplified modelling frameworks. For instance, we reveal that vertical heat flux from the surface dominates the basal heat flux towards a borehole. Both fluxes need to be accounted for as proper vertical boundary conditions in the model. Additionally, the role of horizontal groundwater advection is inspected. Moreover, by adopting the ground energy deficit and long-term replenishment as criteria for system sustainability, an uncommon perspective is adopted that is based on the primary parameter rather than induced local temperatures. In our synthetic study and dimensionless analysis, we demonstrate that time of ground energy recovery after system shutdown may be longer than what is expected from local temperature trends. In contrast, unrealistically long recovery periods and extreme thermal anomalies are predicted without account for vertical ground heat fluxes and only when the energy content of the geothermal reservoir is considered.

  5. Comparative evaluation of ground-coupled heat pumps that use solar energy

    Energy Technology Data Exchange (ETDEWEB)

    Andrews, J.W.; Catan, M.A.

    1985-03-01

    A study of combined building space conditioning systems using both solar energy and heat pumps was conducted for the US Department of Energy (DOE). Several of these systems used the ground as a source or storage element for thermal energy, in order to reduce or eliminate the need for backup energy. This paper summarizes the results obtained for these systems in the United States, and describes the relationship of ground-coupling to the overall US solar-assisted heat-pump program.

  6. Fluid Flow and Heat Transfer Characteristic of Outer and Inner Half Coil Jackets%釜外和釜内螺旋半圆管夹套内流体流动与换热性特性

    Institute of Scientific and Technical Information of China (English)

    李雅侠; 吴剑华; 战洪仁

    2011-01-01

    The physical models of the outer and inner half coil jackets were simplified to two types of coiled ducts. The mathematic models of incompressible fluid at the condition of laminar flow and heat transfer in the two types of jackets for cooling process reactor were set up and solved by the semi-implicit method for pressure linked equations consistent (SIMPLEC) algorithm based on a control volume method. The flow and temperature fields were given and the effects of Dean and Prandtl numbers on flow and heat transfer were studied. The results show that flow in the inner half coil jacket is found to exhibit transition of secondary flow pattern from two vortices to four vortices when the Dean number increases, but that in the outer half coil jacket is not found. The critical Dean number is about 96. The inner half coil jacket has stronger heat transfer ability than the outer half coil jacket and this superiority is more evident with larger Prandtl number. However, as the Dean number is greater than 105, the flow resistance enhances more severely in the inner jacket than the outer jacket. For both jackets, the centers of the heated wall are the poorest for heat transfer.

  7. Non-equilibrium effects evidenced by vibrational spectra during the coil-to-globule transition in poly(N-isopropylacrylamide) subjected to an ultrafast heating-cooling cycle.

    Science.gov (United States)

    Deshmukh, Sanket A; Kamath, Ganesh; Suthar, Kamlesh J; Mancini, Derrick C; Sankaranarayanan, Subramanian K R S

    2014-03-14

    Molecular dynamics simulations in conjunction with finite element calculations are used to explore the conformational dynamics of a thermo-sensitive oligomer, namely poly(N-isopropylacrylamide) (PNIPAM), subjected to an ultra-fast heating-cooling cycle. Finite element (FE) calculations were used to predict the temperature profile resulting from laser-induced heating of the polymer-aqueous system. The heating rate (∼0.6 K ps(-1)) deduced from FE calculations was used to heat an aqueous solution of PNIPAM consisting of 30 monomeric units (30-mer) from 285 K to 315 K. Non-equilibrium effects arising from the ultra-fast heating-cooling cycle results in a hysteresis during the coil-to-globule transition. The corresponding atomic scale conformations were characterized by monitoring the changes in the vibrational spectra, which provided a reliable metric to study the coil-to-globule transition in PNIPAM and vice-versa across the LCST. The vibrational spectra of bonds involving atoms from the oligomer backbone and the various side-groups (amide I, amide II, and the isopropyl group of PNIPAM) of the oligomers were analyzed to study the conformational changes in the oligomer corresponding to the observed hysteresis. The differences in the vibrational spectra calculated at various temperatures during heating and cooling cycles were used to understand the coil-to-globule and globule-to-coil transitions in the PNIPAM oligomer and identify the changes in the relative interactions between various atoms in the backbone and in the side groups of the oligomer with water. The shifts in the computed vibrational spectral peaks and the changes in the intensity of peaks for the different regions of PNIPAM, seen across the LCST during the heating cycle, are in good agreement with previous experimental studies. The changes in the radius of gyration (Rg) and vibrational spectra for amide I and amide II regions of PNIPAM suggest a clear coil-to-globule transition at ∼301 K during the

  8. On the Design and Response of Domestic Ground-Source Heat Pumps in the UK

    Directory of Open Access Journals (Sweden)

    Chris Underwood

    2014-07-01

    Full Text Available The design and response of ground source heat pumps coupled to vertical closed loop arrays in UK domestic applications are investigated in this article. Two typical UK house types are selected as the vehicle for the study and a detailed dynamic thermal modelling method is used to arrive at time-series heating demands for the two houses. A new empirical heat pump model is derived using experimental data taking into account the deteriorating performance of the heat pump during periods of light load. The heat pump model is incorporated into an existing numerical ground model and completed with a classical effectiveness type heat exchange model of the closed loop array. The model is used to analyse array sizing and performance over an extended time period, as well as sensitivity of the design to soil conductivity and borehole heat exchanger resistance and sensitivity to over-sizing and part-load behavior of the heat pump. Results show that the UK’s standard for ground source design (the Microgeneration Certification Scheme may lead to under-estimated array sizes and that heating system over-sizing and deleterious part-load heat pump performance can add up to 20% to the electrical consumption of these systems.

  9. Research Status and Development on Heat Transfer Enhancement of Ground Heat Exchanger used in Ground-coupled Heat Pump%土壤源热泵地埋管传热强化研究现状及其发展

    Institute of Scientific and Technical Information of China (English)

    朱洁莲; 杨卫波; 嵇素雯

    2013-01-01

    The article analyzes the technology characteristics of ground-coupled heat pump and influence factors of heat exchange performance of ground heat exchanger, and points out that heat transfer enhancement of the ground heat exchanger is one of the core problems of the ground coupled heat pump research. The research status on heat transfer enhancement of ground heat exchanger at home and abroad were analyzed in detail, the latest progress and the key problems to be solved about heat transfer enhancement subject were also pointed out.%分析了土壤源热泵技术特点及地埋管换热器的影响因素,指出地埋管换热器传热强化是地源热泵研究的核心问题之一,详细介绍了近十年来地埋管传热强化的国内外研究状况,在此基础上指出了土壤源热泵地埋管传热强化的最新进展和有待解决的关键问题。

  10. Annual investigation of vertical type ground source heat pump system performance on a wall heating and cooling system in Istanbul

    Energy Technology Data Exchange (ETDEWEB)

    Akbulut, U.; Yoru, Y.; Kincay, O. [Department of Mechanical Engineering, Yildiz Technical University (Turkey)], email: akbulutugur@yahoo.com, email: yilmazyoru@gmail.com, email: okincay@yildiz.edu.tr

    2011-07-01

    Wall heating and cooling systems (WHCS) are equipped with heating serpentines or panels for water circulation. These systems operate in a low temperature range so they are preferable to other, conventional systems. Furthermore, when these systems are connected to a ground source heat pump (GSHP) system, energy performance and thermal comfort are further enhanced. The purpose of this paper is to report the results of an annual inspection done on a vertical type ground-coupled heat pump systems (V-GSHP) WHCS in Istanbul and present the results. The performance data from the Yildiz Renewable Energy House at Davutpasa Campus of Yildiz Technical University, Istanbul, Turkey, during the year 2010 were collected and analyzed. The conclusions drawn from the inspection and analysis were listed in this paper. Using renewable energy sources effectively will bring both economic and environmental benefits and it is hoped that the use of these energy efficient WHCS systems will become widespread.

  11. Analysis and field evaluation of an advanced ground-coupled heat pump system

    Energy Technology Data Exchange (ETDEWEB)

    Baxter, V.D. (Oak Ridge National Lab., TN (USA)); Catan, M.A. (Brookhaven National Lab., Upton, NY (USA)); Hughes, H.M. (Climate Master, Inc. (USA)); Hughes, P.J. (Fleming (W.S.) and Associates, Inc., Syracuse, NY (USA)); O' Neil, R.A. (Niagara Mohawk Power Corp., Syracuse, NY (USA))

    1986-01-01

    This paper addresses the performance of a ground-coupled heat pump (GCHP) system with a water-source heat pump (WSHP) package designed expressly for such systems for a northern climate. The research objective was to minimize the life-cycle cost (LCC) of a GCHP system by optimizing the design of both the heat pump package and the ground heat exchanger in concert. The LCC of a GCHP system with a horizontal ground heat exchanger was minimized over a seven-year economic life for an 1800 ft{sup 2} (167 m{sup 2}) house in Pittsburgh, PA, USA. Simple payback for the optimized system, relative to conventional air-source heat pumps (ASHPs), was less than three years. The resulting WSHP design is calculated to cost approximately 20% more than its conventional counterpart, but offers a 20% higher heating coefficient of performance (COP) and a 23% higher cooling COP. The major conclusion of this study is that by improving the WSHP package efficiency, the ground heat exchanger size can be reduced by at least 30% without sacrificing performance; this can yield significant improvement in the cost competitiveness of GCHP systems. 10 refs., 8 figs., 8 tabs.

  12. Technology Solutions Case Study: Ground Source Heat Pump Research, TaC Studios Residence, Atlanta, Georigia

    Energy Technology Data Exchange (ETDEWEB)

    None

    2014-09-01

    This case study describes the construction of a new test home that demonstrates current best practices for the mixed-humid climate, including a high performance ground source heat pump for heating and cooling, a building envelope featuring advanced air sealing details and low-density spray foam insulation, and glazing that exceeds ENERGY STAR requirements.

  13. An Innovative Use of Renewable Ground Heat for Insulation in Low Exergy Building Systems

    Directory of Open Access Journals (Sweden)

    Hansjürg Leibundgut

    2012-08-01

    Full Text Available Ground heat is a renewable resource that is readily available for buildings in cool climates, but its relatively low temperature requires the use of a heat pump to extract it for heating. We developed a system that uses low temperature ground heat directly in a building wall to reduce transmission heat losses. The Active Low Exergy Geothermal Insulation Systems (ALEGIS minimizes exergy demand and maximizes the use of renewable geothermal heat from the ground. A fluid is pumped into a small pipe network in an external layer of a wall construction that is linked to a ground heat source. This decouples the building from the outside temperature, therefore eliminating large peak demands and reducing the primary energy demand. Our steady-state analysis shows that at a design temperature of −10 °C the 6 cm thick active insulation system has equivalent performance to 11 cm of passive insulation. Our comparison of heating performance of a building with our active insulation system versus a building with static insulation of the same thickness shows a 15% reduction in annual electricity demand, and thus exergy input. We present an overview of the operation and analysis of our low exergy concept and its modeled performance.

  14. The effects of neutral gas heating on H mode transition and maintenance currents in a 13.56 MHz planar coil inductively coupled plasma reactor

    Science.gov (United States)

    Jayapalan, Kanesh K.; Chin, Oi-Hoong

    2012-09-01

    The H mode transition and maintenance currents in a 13.56 MHz laboratory 6 turn planar coil inductively coupled plasma (ICP) reactor are simulated for low pressure argon discharge range of 0.02-0.3 mbar with neutral gas heating and at ambient temperature. An experimentally fitted 3D power evolution plot for 0.02 mbar argon pressure is also shown to visualize the effects of hysteresis in the system. Comparisons between simulation and experimental measurements show good agreement in the pressure range of 0.02-0.3 mbar for transition currents and 0.02-0.1 mbar for maintenance currents only when neutral gas heating is considered. This suggests that neutral gas heating plays a non-negligible role in determining the mode transition points of a rf ICP system.

  15. Experimental and CFD Heat Transfer Studies of Al2O3-Water Nanofluid in a Coiled Agitated Vessel Equipped with Propeller

    Institute of Scientific and Technical Information of China (English)

    Thangavelu Perarasu; Mahizhnan Arivazhagan; Palani Sivashanmugam

    2013-01-01

    This paper presents the heat transfer characteristics of Al2O3-water nanofluid in a coiled agitated vessel with propeller agitator. The experimental study was conducted using 0.10%, 0.20%and 0.30%volume concentra-tion of Al2O3-water nanofluids. The results showed considerable enhancement of convective heat transfer using the nanofluids. The empirical correlations developed for Nusselt number in terms of Reynolds number, Prandtl number, viscosity ratio and volume concentration fit with the experimental data within ±10%. The heat transfer characteris-tics were also simulated using computational fluid dynamics using FLUENT software with the standard k-εmodel and multiple reference frame were adopted. The computational fluid dynamics (CFD) predicted Nusselt number agrees well with the experimental value and the discrepancy is found to be less than ±8%.

  16. Research of the Effectiveness of Using Air and Ground Low-grade Heat for Buildings Heating in Different Regions of Russia

    Directory of Open Access Journals (Sweden)

    Vasilyev G.P.

    2016-01-01

    Full Text Available The article presents the results of research on zoning of the Russian Federation based on efficiency of utilization of the low-grade heat of ground and air as well as combinations thereof for heating buildings. When modeling thermal behavior of geothermal HHS in the climatic conditions of various regions of the Russian Federation we considered the effect of long-term recovery of geothermal heat on the thermal behavior of the ground, as well as the effect of the ground pore water phase transitions on the operational efficiency of geothermal heat pump heating systems. The zoning took into account temperature drop of the ground mass caused by many years of heat recovery from the ground. Ground temperatures expected for the 5th year of geothermal HHS operation were used as design ground mass temperatures.

  17. 海水源热泵用盘管换热器的数值模拟研究*%Numerical Simulation on Coil Heat Exchanger for Seawater Source Heat Pump

    Institute of Scientific and Technical Information of China (English)

    吴君华; 于丹; 谢军; 曲艳新

    2013-01-01

      A heat exchanger model is established based on the numerical simulation software FLUENT, in order to study the heat ex-change capacity with coil heat exchanger of seawater source heat pump and determine design parameters. The numerical simulation is com-pared with the experimental data to verify the correctness of the results. The flow rate for design reference is proposed with the simulation of heat transfer rate per unit length. The flow rate in coil is suggested as value of 0.5~0.7 m/s for the seawater source heat pump air conditioning system with coil heat exchanger.%  为了研究海水源热泵用盘管换热器的换热能力,并确定其设计参数值,基于数值模拟软件FLUENT建立了换热器模型,进行了数值模拟,将模拟结果与实验测试值进行了对比分析,验证了其正确性。根据模拟计算出的单位管长换热量,给出设计速度参考取值范围。研究结果为海水源热泵空调系统用盘管换热器夏季换热盘管流速取值范围提供了参考,宜取0.5~0.7 m/s。

  18. Modelling floor heating systems using a validated two-dimensional ground coupled numerical model

    DEFF Research Database (Denmark)

    Weitzmann, Peter; Kragh, Jesper; Roots, Peter

    2005-01-01

    the floor. This model can be used to design energy efficient houses with floor heating focusing on the heat loss through the floor construction and foundation. It is found that it is impor-tant to model the dynamics of the floor heating system to find the correct heat loss to the ground, and further......This paper presents a two-dimensional simulation model of the heat losses and tempera-tures in a slab on grade floor with floor heating which is able to dynamically model the floor heating system. The aim of this work is to be able to model, in detail, the influence from the floor construction...... and foundation on the performance of the floor heating sys-tem. The ground coupled floor heating model is validated against measurements from a single-family house. The simulation model is coupled to a whole-building energy simu-lation model with inclusion of heat losses and heat supply to the room above...

  19. Thermal-economic modeling and optimization of vertical ground-coupled heat pump

    Energy Technology Data Exchange (ETDEWEB)

    Sanaye, Sepehr; Niroomand, Behzad [Energy Systems Improvement Laboratory (ESIL), Department of Mechanical Engineering, Iran University of Science and Technology (IUST), Narmak, Tehran 16488 (Iran)

    2009-04-15

    The optimal design process of a ground source heat pump includes thermal modeling of the system and selection of optimal design parameters which affect the system performance as well as initial and operational costs. In this paper, the modeling and optimizing processes of a ground-coupled heat pump (GCHP) with closed vertical ground heat exchanger (VGHX) are presented. To verify the modeling procedure of heat pump and VGHX systems, the simulation outputs were compared with the corresponding values reported in the literature and acceptable accuracy was obtained. Then an objective function (the sum of annual operating and investment costs of the system) was defined and minimized, exposed to the specified constraints to estimate the optimum design parameters (decision variables). Two Nelder-Mead and genetic algorithm optimization techniques were applied to guarantee the validity of the optimization results. For the given heating/cooling loads and various climatic conditions, the optimum values of heat pump design parameters (saturated temperature/pressure of condenser and evaporator) as well as VGHX design parameters (inlet and outlet temperatures of the ground water source, pipe diameter, depth and number of boreholes) were predicted. Furthermore, the sensitivity analysis of change in the total annual cost of the system and optimum design parameters with the climatic conditions, cooling/heating capacity, soil type, and number of boreholes were discussed. Finally, the sensitivity analysis of change in optimum design parameters with increase in the investment and electricity costs was performed. (author)

  20. Effect of Borehole Material on Analytical Solutions of the Heat Transfer Model of Ground Heat Exchangers Considering Groundwater Flow

    Directory of Open Access Journals (Sweden)

    Sangwoo Park

    2016-04-01

    Full Text Available Groundwater flow is one of the most important factors for the design of a ground heat exchanger (GHEX since the thermal environment of the ground around the buried GHEX is significantly affected by heat convection due to the groundwater flow. Several preceding studies have been conducted to develop analytical solutions to the heat transfer model of GHEX with consideration of groundwater flow. One of these solutions is the combined heat transfer model of conduction and convection. However, the developed combined analytical models are inapplicable to all of the configurations of ordinary GHEXs because these solutions assume that the inner part of the borehole is thermally inert or consists of the same material as that of the surrounding ground. In this paper, the applicability of the combined solid cylindrical heat source model, which is the most suitable to energy piles until now, was evaluated by performing a series of numerical analyses. In the numerical analysis, the inner part of the borehole was modeled as two different materials (i.e., permeable ground formation and impermeable fill such as concrete to evaluate applicability of the analytical solution along with different diameter-length (D/L ratios of borehole. In a small value of the D/L ratio, the analytical solution to the combined heat transfer model is in good agreement with the result of numerical analysis. On the other hand, when increasing the D/L ratio, the analytical solution significantly overestimates the effect of groundwater flow on the heat transfer of GHEXs because the analytical solution disregards the existence of the impermeable region in the borehole. Consequently, such tendency is more critical in the GHEX with a large D/L ratio such as large-diameter energy piles.

  1. HVAC system design of liquid desiccant fresh air unit combined with ground-source heat pump%溶液调湿新风机组与地源热泵相结合的空调设计

    Institute of Scientific and Technical Information of China (English)

    张伟程; 滕汜颖

    2013-01-01

    以上海虹桥产业楼空调系统为例,介绍了溶液调湿新风机组与地源热泵系统的设计,重点介绍了干式末端设备、冷热源主机、地埋管系统、空调水系统及自控系统设计的要点.根据实际运行调试情况,对冷热源水系统、干式风机盘管、高温型地源热泵机组、免费冷热源板式换热器、地源热泵与冷水机组的运行策略及生活热水应用进行了经验总结.%Taking the Shanghai Hongqiao Industrial Building air conditioning system as example, presents the liquid desiccant fresh air unit and ground-source heat pump design. Highlights the design points of the dry terminal device, cold and heat source unit, ground buried pipe system, air conditioning water system and automatic control system. According to the actual operation and commissioning, summarizes experiences of designing the cold and heat sources water system, dry fan-coil unit, high temperature ground-source heat pump, free cold and heat sources plate heat exchanger, water chiller and ground-source heat pump operation strategy and domestic hot water supply.

  2. 基于 Fluent的蛇管换热器耦合传热数值模拟%Numerical Simulation of Coil Heat Exchanger Coupled Heat Transfer Based on Fluent

    Institute of Scientific and Technical Information of China (English)

    房全国; 李家伟; 姜逢章; 刘庆亮; 张志华

    2015-01-01

    According to the structure and process parameters of the coil heat exchanger in a project , numerical simulation of coil heat exchanger coupled heat transfer is done by using Fluent software, and then velocity, pressure, and temperature distributions of tube and shell sides are obtained.The outlet temperature, pressure drop and heat transfer of the tube and shell sides are calculated, and the simulation results are compared with those of the experi-ence calculation values.The relative errors are 3.0%, 0.1%, 2.4%, 28.0%and 1.2%.Simulation results are reliable, and numerical simulation pro-vides a new approach for the heat transfer area and pressure drop calculation of the coil heat exchanger.%结合某工程项目中蛇管换热器的结构和工艺参数,利用Fluent软件对蛇管换热器进行耦合传热数值模拟,得到管壳程的速度、压力和温度分布信息,计算得出管壳程出口温度、压降和换热量,并将模拟结果与经验计算值进行了比较,相对误差分别为3.0%、0.1%、2.4%、28.0%和1.2%,模拟结果可靠,为蛇管换热器换热面积和压降的校核计算提供了新的方法和途径.

  3. Ground-water temperature of the Wyoming quadrangle in central Delaware : with application to ground-water-source heat pumps

    Science.gov (United States)

    Hodges, Arthur L.

    1982-01-01

    Ground-water temperature was measured during a one-year period (1980-81) in 20 wells in the Wyoming Quadrangle in central Delaware. Data from thermistors set at fixed depths in two wells were collected twice each week, and vertical temperature profiles of the remaining 18 wells were made monthly. Ground-water temperature at 8 feet below land surface in well Jc55-1 ranged from 45.0 degrees F in February to 70.1 degrees F in September. Temperature at 35 feet below land surface in the same well reached a minimum of 56.0 degrees F in August, and a maximum of 57.8 degrees F in February. Average annual temperature of ground water at 25 feet below land surface in all wells ranged from 54.6 degrees F to 57.8 degrees F. Variations of average temperature probably reflect the presence or absence of forestation in the recharge areas of the wells. Ground-water-source heat pumps supplied with water from wells 30 or more feet below land surface will operate more efficiently in both heating and cooling modes than those supplied with water from shallower depths. (USGS)

  4. National Certification Standard for Ground Source Heat Pump Personnel

    Energy Technology Data Exchange (ETDEWEB)

    Kelly, John [Geothermal Heat Pump Consortium, Washington, DC (United States)

    2013-07-31

    The National Certification Standard for the Geothermal Heat Pump Industry adds to the understanding of the barriers to rapid growth of the geothermal heat pump (GHP) industry by bringing together for the first time an analysis of the roles and responsibilities of each of the individual job tasks involved in the design and installation of GHP systems. The standard addresses applicable qualifications for all primary personnel involved in the design, installation, commissioning, operation and maintenance of GHP systems, including their knowledge, skills and abilities. The resulting standard serves as a foundation for subsequent development of curriculum, training and certification programs, which are not included in the scope of this project, but are briefly addressed in the standard to describe ways in which the standard developed in this project may form a foundation to support further progress in accomplishing those other efforts. Follow-on efforts may use the standard developed in this project to improve the technical effectiveness and economic feasibility of curriculum development and training programs for GHP industry personnel, by providing a more complete and objective assessment of the individual job tasks necessary for successful implementation of GHP systems. When incorporated into future certification programs for GHP personnel, the standard will facilitate increased consumer confidence in GHP technology, reduce the potential for improperly installed GHP systems, and assure GHP system quality and performance, all of which benefit the public through improved energy efficiency and mitigated environmental impacts of the heating and cooling of homes and businesses.

  5. Horizontal ground coupled heat pump: Thermal-economic modeling and optimization

    Energy Technology Data Exchange (ETDEWEB)

    Sanaye, Sepehr; Niroomand, Behzad [Energy Systems Improvement Laboratory (ESIL), Department of Mechanical Engineering, Iran University of Science and Technology (IUST) (Iran)

    2010-12-15

    The modeling and optimizing processes of a Ground Coupled Heat Pump (GCHP) with closed Horizontal Ground Heat eXchanger (HGHX) are presented in this paper. After thermal modeling of GCHP including HGHX, the optimum design parameters of the system were estimated by minimizing a defined objective function (total of investment and operation costs) subject to a list of constraints. This procedure was performed applying Genetic Algorithm technique. For given heating/cooling loads and various climatic conditions, the optimum values of saturated temperature/pressure of condenser and evaporator as well as inlet and outlet temperatures of the water source in cooling and heating modes were predicted. Then, for our case study, the design parameters as well as the configuration of HGHX were obtained. Furthermore, the sensitivity analysis of change in the total annual cost of the system and optimum design parameters with the climatic conditions, cooling/heating capacity, and soil type were discussed. (author)

  6. Analysis of Short Time Period of Operation of Horizontal Ground Heat Exchangers

    Directory of Open Access Journals (Sweden)

    Salsuwanda Selamat

    2015-07-01

    Full Text Available Ground source heat pump (GSHP systems have been proven to have higher efficiency compared to conventional air source heat pump systems for space heating and cooling applications. While vertical ground heat exchangers (GHE are favorable in GSHP installation, this type of configuration requires higher capital costs as opposed to horizontal configuration. Numerical simulation has been used to accurately predict the thermal performance of GHE. In this paper, numerical analysis of thermal performance for slinky horizontal GHE loops in different orientations and operation modes is discussed. It was found that the loop orientation is not so important due to the little effect it has on thermal performance. While the mean heat exchange rate of copper loop increases 48% compared to HDPE loop, the analysis supports the common claim that heat exchange rate is predominantly limited by the thermal conductivity of the ground. With the same amount of circulation work, the mean heat exchange rate increases by 83%–162% when operated in parallel loops operations. The performance in these operations can be further optimized to 10%–14% increase when spacing between adjacent loops was provided. The spacing helps to minimize interference of heat flow that would penalize the overall thermal performance.

  7. Study on the Performance of a Ground Source Heat Pump System Assisted by Solar Thermal Storage

    Directory of Open Access Journals (Sweden)

    Yu Jin Nam

    2015-11-01

    Full Text Available A ground source heat pump system (GSHPS utilizes a relatively stable underground temperature to achieve energy-saving for heating and cooling in buildings. However, continuous long-term operation will reduce the soil temperature in winter, resulting in a decline in system performance. In this research, in order to improve the system performance of a GSHPS, a ground heat pump system integrated with solar thermal storage was developed. This solar-assisted ground heat pump system (SAGHPS can both maintain the balance of the soil temperature effectively and achieve higher system performance than the conventional system. In this paper, in order to examine the characteristics of the system, a dynamic simulation was conducted under various conditions. The results of our case study provide specific operation data such as heat exchange rate, heat source temperature, and heat pump COP. As a result, the heat pump COP of SAGHPS was 4.7%, 9.3% higher than that of the GSHPS.

  8. Thermal Performance of Thin Type Radiant Floor Heating Combined with Fan-coil Heating%轻薄水地暖与分机盘管联合供暖热工性能研究

    Institute of Scientific and Technical Information of China (English)

    陈英杰; 李维; 陈立楠; 罗汉

    2014-01-01

    An experimental room was setted up for the heating system as research object, the heat source is air-source heat pump, the extreme is thin type radiant floor heating system combined with fan-coil heating system. The floor heating temperature and thermal performance under stable conditions are researched. The electricity consumption of fan-coil heating, radiant floor heating and radiant floor heating with fan-coil were analyzed through the data recorded by the meter. The value of the COP under three ways were compared after the calculation. Results indicate the indoor temperature response speed of the combined heating system is fast. Within the scope of the indoor temperature requirements, the average floor surface temperature is appropriate with less electricity consumption, the combined heating system is more energy-saving and more comfortable.%以空气源热泵为热源、风机盘管与地板辐射为末端的供暖系统作为研究对象,搭建了实验房间,对轻薄水地暖与风机盘管在供暖系统中的升温和稳定工况下的热工性能进行了实验研究,通过电表记录的数据比较了单开风盘连续运行、单开地板供暖连续运行、同时地板与风机盘管联合供暖各自的耗电量,通过计算比较了3种方式下的COP值,得出地板辐射与风机盘管联合供暖的室内温度响应速度快,在室内温度要求范围内,地板表面平均温度适宜、耗电量少,地板辐射与风机盘管联合供暖方式更节能、更舒适。

  9. Analysis of Fuel Cell Driven Ground Source Heat Pump Systems in Community Buildings

    Directory of Open Access Journals (Sweden)

    Jong-Keun Shin

    2013-05-01

    Full Text Available In the present study, a fuel cell driven ground source heat pump (GSHP system is applied in a community building and heat pump system performance is analyzed by computational methods. Conduction heat transfer between the brine pipe and ground is analyzed by TEACH code in order to predict the performance of the heat pump system. The predicted coefficient of performance (COP of the heat pump system and the energy cost were compared with the variation of the location of the objective building, the water saturation rate of the soil, and the driven powers of the heat pump system. Compared to the late-night electricity driven system, a significant reduction of energy cost can be accomplished by employing the fuel cell driven heat pump system. This is due to the low cost of electricity production of the fuel cell system and to the application of the recovered waste heat generated during the electricity production process to the heating of the community building.

  10. Optimization of Serial Combined System of Ground-Coupled Heat Pump and Solar Collector

    Institute of Scientific and Technical Information of China (English)

    ZHAO Jun; CHEN Yan; LU Suzhen; CUI Junkui

    2009-01-01

    A mathematical optimization model was set up for a ground-solar combined system based on in-situ experimental results,in which the solar collector was combined serially with a ground-coupled heat pump(GCHP).The universal optimal equations were solved by the constrained variable metric method considering both the performance and economics.Then the model was applied to a specific case concerning an actual solar assisted GCHP system for space heating.The results indicated a system coefficient of performance(COP)of 3.9 for the optimal method under the seriaI heating mode,and 3.2 for the conventional one.In addition,the optimum solution also showed advantages in energy and cost saving.1eading to a 16.7%improvement in the heat pump performance at 17.2%less energy consumption and 11.8%lower annual cost,respectively.

  11. COMPARATIVE STUDY AMONG HYBRID GROUND SOURCE HEAT PUMP SYSTEM, COMPLETE GROUND SOURCE HEAT PUMP AND CONVENTIONAL HVAC SYSTEM

    Energy Technology Data Exchange (ETDEWEB)

    Jiang Zhu; Yong X. Tao

    2011-11-01

    In this paper, a hotel with hybrid geothermal heat pump system (HyGSHP) in the Pensacola is selected and simulated by the transient simulation software package TRNSYS [1]. To verify the simulation results, the validations are conducted by using the monthly average entering water temperature, monthly facility consumption data, and etc. And three types of HVAC systems are compared based on the same building model and HVAC system capacity. The results are presented to show the advantages and disadvantages of HyGSHP compared with the other two systems in terms of energy consumptions, life cycle cost analysis.

  12. Finite Volume Based Computer Program for Ground Source Heat Pump System

    Energy Technology Data Exchange (ETDEWEB)

    Menart, James A. [Wright State University

    2013-02-22

    This report is a compilation of the work that has been done on the grant DE-EE0002805 entitled ?Finite Volume Based Computer Program for Ground Source Heat Pump Systems.? The goal of this project was to develop a detailed computer simulation tool for GSHP (ground source heat pump) heating and cooling systems. Two such tools were developed as part of this DOE (Department of Energy) grant; the first is a two-dimensional computer program called GEO2D and the second is a three-dimensional computer program called GEO3D. Both of these simulation tools provide an extensive array of results to the user. A unique aspect of both these simulation tools is the complete temperature profile information calculated and presented. Complete temperature profiles throughout the ground, casing, tube wall, and fluid are provided as a function of time. The fluid temperatures from and to the heat pump, as a function of time, are also provided. In addition to temperature information, detailed heat rate information at several locations as a function of time is determined. Heat rates between the heat pump and the building indoor environment, between the working fluid and the heat pump, and between the working fluid and the ground are computed. The heat rates between the ground and the working fluid are calculated as a function time and position along the ground loop. The heating and cooling loads of the building being fitted with a GSHP are determined with the computer program developed by DOE called ENERGYPLUS. Lastly COP (coefficient of performance) results as a function of time are provided. Both the two-dimensional and three-dimensional computer programs developed as part of this work are based upon a detailed finite volume solution of the energy equation for the ground and ground loop. Real heat pump characteristics are entered into the program and used to model the heat pump performance. Thus these computer tools simulate the coupled performance of the ground loop and the heat pump

  13. Recovery Act: Finite Volume Based Computer Program for Ground Source Heat Pump Systems

    Energy Technology Data Exchange (ETDEWEB)

    James A Menart, Professor

    2013-02-22

    This report is a compilation of the work that has been done on the grant DE-EE0002805 entitled Finite Volume Based Computer Program for Ground Source Heat Pump Systems. The goal of this project was to develop a detailed computer simulation tool for GSHP (ground source heat pump) heating and cooling systems. Two such tools were developed as part of this DOE (Department of Energy) grant; the first is a two-dimensional computer program called GEO2D and the second is a three-dimensional computer program called GEO3D. Both of these simulation tools provide an extensive array of results to the user. A unique aspect of both these simulation tools is the complete temperature profile information calculated and presented. Complete temperature profiles throughout the ground, casing, tube wall, and fluid are provided as a function of time. The fluid temperatures from and to the heat pump, as a function of time, are also provided. In addition to temperature information, detailed heat rate information at several locations as a function of time is determined. Heat rates between the heat pump and the building indoor environment, between the working fluid and the heat pump, and between the working fluid and the ground are computed. The heat rates between the ground and the working fluid are calculated as a function time and position along the ground loop. The heating and cooling loads of the building being fitted with a GSHP are determined with the computer program developed by DOE called ENERGYPLUS. Lastly COP (coefficient of performance) results as a function of time are provided. Both the two-dimensional and three-dimensional computer programs developed as part of this work are based upon a detailed finite volume solution of the energy equation for the ground and ground loop. Real heat pump characteristics are entered into the program and used to model the heat pump performance. Thus these computer tools simulate the coupled performance of the ground loop and the heat pump. The

  14. Using Ground Source Heat Pumps for Renewable Energy

    Directory of Open Access Journals (Sweden)

    Xhevat BERISHA

    2017-04-01

    Full Text Available This paper provides background information on the current energy supply, energy demand, and energy sources in Kosovo. Moreover, it presents the country‟s current level of applying alternative energy sources. Additionally, this paper focuses on geothermal energy as a renewable energy resource with the potential to contribute to a sustainable use of resources to meet renewable energy and energy efficiency requirements of the European Union (EU, “EU 20 20 by 2020” policy. Hence, a careful analysis is included on how to approach the aforementioned targets through investments in geothermal energy through providing an energy consumption forecast and analysing geothermal energy projects in Europe and specifically in Kosovo. This paper carefully represents the potential usage of geothermal energy in Kosovo, renewable energy source targets, and it addresses the importance of laws, regulations, and reports regarding the utilization of this type of energy. Economic and environmental implications of investing in geothermal energy - geothermal heat pumps for the case of International Village are additionally analysed. Lastly, recommendations and conclusions, for future actions, are derived and addressed to relevant stakeholders, primarily policy-makers, and government representatives.

  15. Influence of the heat treatment on the color of ground pepper (Capsicum annuum

    Directory of Open Access Journals (Sweden)

    Vračar Ljubo O.

    2007-01-01

    Full Text Available Red pepper (Capsicum annuum L. is one of the most important vegetables in the world. The main ground pepper quality attributes are extractable color, surface color, qualitative and quantitative carotenoid content. In this work, the influence of heat treatment on ground pepper quality was investigated. Microbiological status was examined in non-sterilized and sterilized ground pepper. Color changes were assessed by measuring the extractable color (ASTA and surface color, using a photocolorimeter. The obtained results showed that at the end of experiment, non-sterilized samples had higher color values in comparison to the sterilized ones. Also, color deterioration was heightened at room temperature.

  16. Sensitivity analysis on the performances of a closed-loop Ground Source Heat Pump

    Science.gov (United States)

    Casasso, Alessandro; Sethi, Rajandrea

    2014-05-01

    Ground Source Heat Pumps (GSHP) permit to achieve a significant reduction of greenhouse gas emissions, and the margins for economic saving of this technology are strongly correlated to the long-term sustainability of the exploitation of the heat stored in the soil. The operation of a GSHP over its lifetime should be therefore modelled considering realistic conditions, and a thorough characterization of the physical properties of the soil is essential to avoid large errors of prediction. In this work, a BHE modelling procedure with the finite-element code FEFLOW is presented. Starting from the governing equations of the heat transport in the soil around a GSHP and inside the BHE, the most important parameters are individuated and the adopted program settings are explained. A sensitivity analysis is then carried on both the design parameters of the heat exchanger, in order to understand the margins of improvement of a careful design and installation, and the physical properties of the soil, with the aim of quantifying the uncertainty induced by their variability. The relative importance of each parameter is therefore assessed by comparing the statistical distributions of the fluid temperatures and estimating the energy consumption of the heat pump, and practical conclusions are from these results about the site characterization, the design and the installation of a BHE. References Casasso A., Sethi R., 2014 Efficiency of closed loop geothermal heat pumps: A sensitivity analysis, Renewable Energy 62 (2014), pp. 737-746 Chiasson A.C., Rees S.J., Spitler J.D., 2000, A preliminary assessment of the effects of groundwater flow on closed-loop ground-source heat pump systems, ASHRAE Transactions 106 (2000), pp. 380-393 Delaleux F., Py X., Olives R., Dominguez A., 2012, Enhancement of geothermal borehole heat exchangers performances by improvement of bentonite grouts conductivity, Applied Thermal Engineering 33-34, pp. 92-99 Diao N., Li Q., Fang Z., 2004, Heat transfer in

  17. Study of the Dependence Effectiveness of Low-potential Heat of the Ground and Atmospheric Air for Heating Buildings from Climatic parameters

    Directory of Open Access Journals (Sweden)

    Vasilyev Gregory P.

    2016-01-01

    Full Text Available The article represents the results of researches for division into districts of the territory of Russia and Europe by efficiency of using for the heat supply of buildings of low-potential thermal energy of ground and free air and their combination. While modeling of the heat regime of geothermal HPS in climatic conditions of different regions of the territory of Russia, the influence has been taken into account of the long-term extraction of geothermal heat energy on the ground heat regime as well as the influence of phase transitions of pore moisture in ground on the efficiency of operation of geothermal heat-pump heat-supply systems. While realization of the division into districts, the sinking of temperatures of ground massive was been taken into account which has been called by long-term extraction of the heat energy from the ground, and as calculation parameters of the heat energy from the ground, and as calculation parameters of ground massive temperatures, the ground temperatures were used which are waited for the 5-th year of operation of geothermal HPS.

  18. Study on the Effect of Ground Heat Storage by Solar Heat Using Numerical Simulation

    Directory of Open Access Journals (Sweden)

    Jin-Hwan Oh

    2015-12-01

    Full Text Available Recently, energy storage techniques using renewable energy efficiently have attracted considerable attention. However, there are several problems when using renewable energy. In the case of solar energy, the energy production time is different from the consumption time, and the use of geothermal energy has high investment costs. In order to solve these problems, it is essential to develop high-efficiency systems using both solar and geothermal energy simultaneously and efficiently. Thus, in this study, the performance of underground heat storage of solar energy was examined by simulation using models of underground heat transfer and heat exchange for the development of an integrated hybrid system exploiting both geothermal and solar energy. As a result, the heat extraction performance was determined to be up to 72.75 W/m. As a result, in Kagoshima, the most southern area in Korea, a case of six hour heat storage operation achieved the highest heat exchange rate of 72.75 W/m, which is approximately 105% higher than the case of operation without heat storage.

  19. Heat-stop structure design with high cooling efficiency for large ground-based solar telescope.

    Science.gov (United States)

    Liu, Yangyi; Gu, Naiting; Rao, Changhui; Li, Cheng

    2015-07-20

    A heat-stop is one of the most important thermal control devices for a large ground-based solar telescope. For controlling the internal seeing effect, the temperature difference between the heat-stop and the ambient environment needs to be reduced, and a heat-stop with high cooling efficiency is required. In this paper, a novel design concept for the heat-stop, in which a multichannel loop cooling system is utilized to obtain higher cooling efficiency, is proposed. To validate the design, we analyze and compare the cooling efficiency for the multichannel and existing single-channel loop cooling system under the same conditions. Comparative results show that the new design obviously enhances the cooling efficiency of the heat-stop, and the novel design based on the multichannel loop cooling system is obviously better than the existing design by increasing the thermal transfer coefficient.

  20. Impact factors on the long-term sustainability of Borehole Heat Exchanger coupled Ground Source Heat Pump System

    Science.gov (United States)

    Shao, Haibing; Hein, Philipp; Görke, Uwe-Jens; Bucher, Anke; Kolditz, Olaf

    2016-04-01

    In recent years, Ground Source Heat Pump System (GSHPS) has been recognized as an efficient technology to utilize shallow geothermal energy. Along with its wide application, some GSHPS are experiencing a gradual decrease in Borehole Heat Exchanger (BHE) outflow temperatures and thus have to be turned off after couple of years' operation. A comprehensive numerical investigation was then performed to model the flow and heat transport processes in and around the BHE, together with the dynamic change of heat pump efficiency. The model parameters were based on the soil temperature and surface weather condition in the Leipzig area. Different scenarios were modelled for a service life of 30 years, to reveal the evolution of BHE outflow and surrounding soil temperatures. It is found that lateral groundwater flow and using BHE for cooling will be beneficial to the energy recovery, along with the efficiency improvement of the heat pump. In comparison to other factors, the soil heat capacity and thermal conductivity are considered to have minor impact on the long-term sustainability of the system. Furthermore, the application of thermally enhanced grout material will improve the sustainability and efficiency. In contrast, it is very likely that undersized systems and improper grouting are the causes of strong system degradation.

  1. Advantages of analytically computing the ground heat flux in land surface models

    Science.gov (United States)

    Pauwels, Valentijn R. N.; Daly, Edoardo

    2016-11-01

    It is generally accepted that the ground heat flux accounts for a significant fraction of the surface energy balance. In land surface models, the ground heat flux is typically estimated through a numerical solution of the heat conduction equation. Recent research has shown that this approach introduces errors in the estimation of the energy balance. In this paper, we calibrate a land surface model using a numerical solution of the heat conduction equation with four different vertical spatial resolutions. It is found that the thermal conductivity is the most sensitive parameter to the spatial resolution. More importantly, the thermal conductivity values are directly related to the spatial resolution, thus rendering any physical interpretation of this value irrelevant. The numerical solution is then replaced by an analytical solution. The results of the numerical and analytical solutions are identical when fine spatial and temporal resolutions are used. However, when using resolutions that are typical of land surface models, significant differences are found. When using the analytical solution, the ground heat flux is directly calculated without calculating the soil temperature profile. The calculation of the temperature at each node in the soil profile is thus no longer required, unless the model contains parameters that depend on the soil temperature, which in this study is not the case. The calibration is repeated, and thermal conductivity values independent of the vertical spatial resolution are obtained. The main conclusion of this study is that care must be taken when interpreting land surface model results that have been obtained using numerical ground heat flux estimates. The use of exact analytical solutions, when available, is recommended.

  2. Study on the System Design of a Solar Assisted Ground Heat Pump System Using Dynamic Simulation

    Directory of Open Access Journals (Sweden)

    Min Gyung Yu

    2016-04-01

    Full Text Available Recently, the use of hybrid systems using multiple heat sources in buildings to ensure a stable energy supply and improve the system performance has gained attention. Among them, a heat pump system using both solar and ground heat was developed and various system configurations have been introduced. However, establishing a suitable design method for the solar-assisted ground heat pump (SAGHP system including a thermal storage tank is complicated and there are few quantitative studies on the detailed system configurations. Therefore, this study developed three SAGHP system design methods considering the design factors focused on the thermal storage tank. Using dynamic energy simulation code (TRNSYS 17, individual performance analysis models were developed and long-term quantitative analysis was carried out to suggest optimum design and operation methods. As a result, it was found that SYSTEM 2 which is a hybrid system with heat storage tank for only a solar system showed the highest average heat source temperature of 14.81 °C, which is about 11 °C higher than minimum temperature in SYSTEM 3. Furthermore, the best coefficient of performance (COP values of heat pump and system were 5.23 and 4.32 in SYSYEM 2, using high and stable solar heat from a thermal storage tank. Moreover, this paper considered five different geographical and climatic locations and the SAGHP system worked efficiently in having high solar radiation and cool climate zones and the system COP was 4.51 in the case of Winnipeg (Canada where the highest heating demand is required.

  3. Temperature and energy deficit in the ground during operation and recovery phases of closed-loop ground source heat pump system: Effect of the groundwater flow

    Science.gov (United States)

    Erol, Selcuk; Francois, Bertrand

    2016-04-01

    The advection/dispersion mechanism of the groundwater flow in the ground has a significant effect on a borehole heat exchanger (BHE) to enhance its thermal performance. However, the amount of energy extracted from the ground never disappears and only shifts with the magnitude of the effective thermal velocity in the infinite domain. In this work, we focus on the temperature and the energy balance of the ground in an advection/dispersion dominated heat transfer system during the operation period of a BHE and the subsequent recovery phase when the system is idle. The problem is treated with single BHE and multi-BHEs systems, for different representative geology and different groundwater flow velocity. In order to assess the thermal energy deficit due to heat extraction from the ground, we used the finite line source analytical model, developed recently (Erol et al., 2015) that provides the temperature distributions around the boreholes for discontinuous heat extraction. The model is developed based on the Green's function, which is the solution of heat conduction/advection/dispersion equation in porous media, for discontinuous heat extraction by analytically convoluting rectangular function or pulses in time domain. The results demonstrate the significant positive impact of the groundwater flow for the recovery in terms of temperature deficit at the location of the borehole. However, the total thermal energy deficit is not affected by the groundwater movement. The energy balance of the ground is the same no matter the prevailing heat transfer system, which can be only conduction or advection/dispersion. In addition, the energy balance of the ground is not based on either the duration of the production period operation or of the recovery phase, but depends on the total amount of heat that is extracted and on the bulk volumetric heat capacity of the ground.

  4. Performance and Economic Modeling of Horizontally Drilled Ground-Source Heat Pumps in Select California Climates

    Science.gov (United States)

    Wiryadinata, Steven

    Service life modeling was performed to gage the viability of unitary 3.5 kWt, ground-source terminal heat pumps (GTHP) employing horizontal directionally drilled geothermal heat exchangers (GHX) over air-source terminal heat pumps (PTHP) in hotels and motels and residential apartment building sectors in California's coastal and inland climates. Results suggest the GTHP can reduce hourly peak demand for the utility by 7%-25% compared to PTHP, depending on the climate and building type. The annual energy savings, which range from -1% to 5%, are highly dependent on the GTHP pump energy use relative to the energy savings attributed to the difference in ground and air temperatures (DeltaT). In mild climates with small ?T, the pump energy use may overcome any advantage to utilizing a GHX. The majority of total levelized cost savings - ranging from 0.18/ft2 to 0.3/ft 2 - are due to reduced maintenance and lifetime capital cost normally associated with geothermal heat pump systems. Without these reductions (not validated for the GTHP system studied), the GTHP technology does not appear to offer significant advantages over PTHP in the climate zones studied here. The GTHP levelized cost was most sensitive to variations in installed cost and in some cases, energy use (influenced by climate zone choice), which together highlights the importance of climate selection for installation, and the need for larger market penetration of ground-source systems in order to bring down installed costs as the technology matures.

  5. Dimensionless Maps for the Validity of Analytical Ground Heat Transfer Models for GSHP Applications

    Directory of Open Access Journals (Sweden)

    Paolo Conti

    2016-10-01

    Full Text Available This article provides plain and handy expressions to decide the most suitable analytical model for the thermal analysis of the ground source in vertical ground-coupled heat pump applications. We perform a comprehensive dimensionless analysis of the reciprocal deviation among the classical infinite, finite, linear and cylindrical heat source models in purely conductive media. Besides, we complete the framework of possible boreholes model with the “hollow” finite cylindrical heat source solution, still lacking in the literature. Analytical expressions are effective tools for both design and performance assessment: they are able to provide practical and general indications on the thermal behavior of the ground with an advantageous tradeoff between calculation efforts and solution accuracy. This notwithstanding, their applicability to any specific case is always subjected to the coherence of the model assumptions, also in terms of length and time scales, with the specific case of interest. We propose several dimensionless criteria to evaluate when one model is practically equivalent to another one and handy maps that can be used for both design and performance analysis. Finally, we found that the finite line source represents the most suitable model for borehole heat exchangers (BHEs, as it is applicable to a wide range of space and time scales, practically providing the same results of more complex models.

  6. Extended lateral heating of the nighttime ionosphere by ground-based VLF transmitters

    OpenAIRE

    İnan, Umran Savaş; Graf, K. L.; Spasojevic, M.; Marshall, R. A.; Lehtinen, N. G.; Foust, F. R.

    2013-01-01

    JOURNAL OF GEOPHYSICAL RESEARCH: SPACE PHYSICS, VOL. 118, 7783–7797, doi:10.1002/2013JA019337, 2013 Extended lateral heating of the nighttime ionosphere by ground-based VLF transmitters K. L. Graf,1 M. Spasojevic,1 R. A. Marshall,2 N. G. Lehtinen,1 F. R. Foust,1 and U. S. Inan1,3 Received 16 August 2013; revised 9 October 2013; accepted 11 November 2013; published 3 December 2013. [1] The effects of ground-based very low frequency (VLF) transmitters on the lower ionospher...

  7. Thermal calculation of ground contact structures: Correction factors of environment- and structure-dependent effects on the heat transfer coefficient

    OpenAIRE

    Nagy, Balázs

    2015-01-01

    The heat loss at ground contact structures is taken into consideration in building heat loss calculations. However, the heat loss through the ground depends not only the soil and the building structure, but the environment as well. New calculation methods based on parametrized transient finite element thermal modelling are introduced in the preceding research article [3]. This paper is the further demonstration of the methods’ environment- or structure-depending correction factors which descr...

  8. Local/global analysis applications to ground-coupled heat transfer

    Energy Technology Data Exchange (ETDEWEB)

    Al-Anzi, Adnan [College of Engineering, Department of Architecture, Kuwait University, P.O. Box 5969, Code No. 13060, Safat (Kuwait); Krarti, Moncef [CEAE Department, CB 428, University of Colorado, 80309, Boulder, CO (United States)

    2003-09-01

    In this paper, a new local/global analysis technique is developed to solve multi-dimensional ground-coupled heat transfer problems. In particular, the novel method is applied in this paper to determine foundation heat transfer for buildings with slab-on-grade floors. It is found that analytical solutions can be used successfully to capture thermal bridging effect when integrated in the developed local/global analysis technique. In addition, it is found that significant savings in computational effort can be achieved with no sacrifice in accuracy when local/global analysis is used. (authors)

  9. Zoning of the Territory of Russia According to the Efficiency of the Use of Low-Grade Ground Heat for Heating

    Directory of Open Access Journals (Sweden)

    Vasilyev G.P.

    2015-01-01

    Full Text Available This paper reports the results of study on the effectiveness of using low-grade ground heat in heat pump systems under the climatic conditions of Russia. The study was performed using the software package “INSOLAR.GSHP.12”, which simulates the non-stationary thermal conditions of ground source heat pumps (GSHPs over several years of operation. The paper presents the results of the zoning of the territory of Russia according to the effectiveness of using low-grade ground heat in heat pump systems. The zoning was performed with consideration of the decrease of the soil temperatures over several years of heat collection system operation. The soil temperatures expected on the fifth year of operation were considered to be the design temperatures. The described study was performed with the financial support of the Ministry of Education and Science of Russia. Contract ID RFMEFI57914X0026.

  10. 内置螺旋弹簧换热管内流动与传热三维数值模拟%3D numerical simulation of fluid flow and heat transfer in heat exchange tube with helical coil inserts

    Institute of Scientific and Technical Information of China (English)

    徐建民; 彭坤; 胡小霞; 黄伟; 余海燕

    2012-01-01

    In order to investigate single-tube heat transfer enhancement principles of heat exchange tube with helical coil inserts,the flow and heat transfer characteristics were simulated using Fluent software.The effects of spring application on flow field,pressure drop and heat transfer performance were investigated.The pitch of coil spring was set as 2 mm,4 mm,5 mm.The effects of spring pitch on the heat transfer enhancement performance were analyzed.The numerical results showed that the fluid in tube with helical coil inserts presents the helical flow,the cutting speed and the radial velocity of flow near the wall had been improved to some extent.Thus the fluid was mixed completely,boundary layer was disturbed fully and heat was exchanged thoroughly.And the temperature difference between inlet and outlet increased as well,with the maximum increase of 0.9 ℃.Under the conditions of the same Reynolds number,the Nusselt number in tube with helical coil inserts was higher than plain tube,but pressure drop and friction factor increased obviously.With the reduced spring pitch,heat transfer was enhanced and friction factor was increased.%为研究内置螺旋弹簧换热管单管强化传热原理,采用Fluent软件对内置螺旋弹簧换热管内流体流动与传热特性进行数值模拟,考察了弹簧的应用对管内流场、压降和换热性能的影响,并分别取螺旋弹簧节距p分别为2 mm、4 mm、5 mm初步研究了弹簧的节距对强化传热效果的影响。模拟结果显示:弹簧管内流体呈螺旋流动状态,管壁附近流体切向速度和径向速度有一定程度的提高,从而加剧了管内流体的混合及边界层的扰动,充分换热,弹簧管进出口温度差较光管有所增加,最高增加了0.9℃;相同雷诺数条件下,内置螺旋弹簧换热管Nu数均高于光管,而压降和阻力系数相比光管有明显增加,随着弹簧节距减小换热增强而摩擦阻力系数增加。

  11. Thermal inactivation of Bacillus anthracis Sterne in irradiated ground beef heated in a water bath or cooked on commercial grills

    Science.gov (United States)

    The thermal stability of heat-shocked and non heat-shocked spores of the virulence-attenuated Sterne strain of Bacillus anthracis was evaluated at select temperatures in irradiated, raw ground beef (25% fat) heated in a water bath or cooked using two different commercial grills. For the former, 3-g ...

  12. 太阳能辅助地源热泵供暖实验研究%Experimental study of a solar assisted ground source heat pump for heating

    Institute of Scientific and Technical Information of China (English)

    赵忠超; 丰威仙; 巩学梅; 米浩君; 成华; 云龙

    2014-01-01

    An experimental study is performed to determine the performance of the solar assisted ground source heat pump(SAGSHP)by using a solar-ground source heat pump hybrid system in the city of Ningbo. The result shows that comparing with the ground source heat pump(GSHP),when the ratio of solar energy to the whole en-ergy is 41. 9% ,the coefficient of performance( COP)of the heat pump and system can improve 15. 1% and 7. 7% respectively. Therefore,the solar assisted ground source heat pump has a significant performance advan-tage according to the experimental result.%选取宁波某公用建筑的太阳能-地源热泵复合系统为实验系统,对太阳能辅助地源热泵( solar assisted ground source heat pump,SAGSHP)供暖进行了实验研究.研究结果表明:与单一的地源热泵(ground source heat pump,GSHP)相比,当太阳能承担41.9%负荷时,热泵机组和整个系统的能效比(coefficient of performance,COP)分别提高了15.1%和7.7%, SAGSHP 供暖运行模式具有明显的性能优势.

  13. Heat as a tool for studying the movement of ground water near streams

    Science.gov (United States)

    Stonestrom, David A.; Constantz, Jim

    2003-01-01

    and practical constraints. As an alternative, naturally occurring variations in temperature can be used to track (or trace) the heat carried by flowing water. The hydraulic transport of heat enables its use as a tracer. Differences between temperatures in the stream and surrounding sediments are now being analyzed to trace the movement of ground water to and from streams. As shown in the subsequent chapters of this circular, tracing the transport of heat leads to a better understanding of the magnitudes and mechanisms of stream/ground-water exchanges, and helps quantify the resulting effects on stream and streambed temperatures. Chapter 1 describes the general principals and procedures by which the natural transport of heat can be utilized to infer the movement of subsurface water near streams. This information sets the foundation for understanding the advanced applications in chapters 2 through 8. Each of these chapters provides a case study, using heat tracing as a tool, of interactions between surface water and ground water for a different location in the western United States. Technical details of the use of heat as an environmental tracer appear in appendices.

  14. Application analysis of ground source heat pumps in building space conditioning

    Energy Technology Data Exchange (ETDEWEB)

    Qian, Hua; Wang, Yungang

    2013-07-01

    The adoption of geothermal energy in space conditioning of buildings through utilizing ground source heat pump (GSHP, also known as geothermal heat pump) has increased rapidly during the past several decades. However, the impacts of the GSHP utilization on the efficiency of heat pumps and soil temperature distribution remained unclear and needs further investigation. This paper presents a novel model to calculate the soil temperature distribution and the coefficient of performance (COP) of GSHP. Different scenarios were simulated to quantify the impact of different factors on the GSHP performance, including heat balance, daily running mode, and spacing between boreholes. Our results show that GSHP is suitable for buildings with balanced cooling and heating loads. It can keep soil temperature at a relatively constant level for more than 10 years. Long boreholes, additional space between boreholes, intermittent running mode will improve the performance of GSHP, but large initial investment is required. The improper design will make the COP of GSHP even lower than traditional heat pumps. Professional design and maintenance technologies are greatly needed in order to promote this promising technology in the developing world.

  15. Comparison of Heat and Bromide as Ground Water Tracers Near Streams

    Science.gov (United States)

    Constantz, J.; Cox, M.H.; Su, G.W.

    2003-01-01

    Heat and bromide were compared as tracers for examining stream/ground water exchanges along the middle reaches of the Santa Clara River, California, during a 10-hour surface water sodium bromide injection test. Three cross sections that comprise six shallow (sodium bromide injection test. Vertical, one-dimensional simulations of bromide concentrations in the sediments yielded a good match to the observed bromide concentrations, without adjustment of any model parameters except solute dispersivities. This indicates that, for the spatial and temporal scales examined on the Santa Clara River, the use of heat and bromide as tracers provide comparable information with respect to apparent hydraulic conductivities and fluxes for sediments near streams. In other settings, caution should be used due to differences in the nature of conservative (bromide) versus nonconservative (heat) tracers, particularly when preferential flowpaths are present.

  16. 连续管线管在青海油田地面集输管线的应用%Coiled Tubing Application in Qinghai Oil Field Ground Gathering Pipeline

    Institute of Scientific and Technical Information of China (English)

    魏强; 王琪; 秦跃平; 张阿军

    2013-01-01

    针对目前油田地面集输管线采用无缝管单根焊接方式造成的焊口多、空气污染严重、劳动强度高等问题,使用连续管线管替代无缝管进行地面集输管线项目试验.介绍了试验用连续管线管的拉伸性能,以及试验现场布管、焊接、焊后水压试验、防腐层补伤等工艺过程.试验结果表明,与无缝管相比,连续管线管用作地面集输管线具有施工效率高、安全性及质量可靠等优点.%Aiming at some problems occurred in adopting seamless steel pipe to conduct each single pipe welding in oil field ground gathering pipeline, such as many welded junction, serious air pollution, high labour intensity and so on. It adopted coiled tubing to replace seamless steel pipe to carry out ground gathering pipeline trial project, introduced the tensile performance of coiled tubing used in experiment, layout pipe in field, welding, hydrostatic test after welding, coating repaire and other process. The test results indicated that compared with seamless steel pipe, coiled tubing used for ground gathering pipeline is with high construction efficiency, high safety, reliable quality and etc.

  17. Partial Nucleate Pool Boiling at Low Heat Flux: Preliminary Ground Test for SOBER-SJ10

    Science.gov (United States)

    Wu, Ke; Li, Zhen-Dong; Zhao, Jian-Fu; Li, Hui-Xiong; Li, Kai

    2016-05-01

    Focusing on partial nucleate pool boiling at low heat flux, SOBER-SJ10, one of 27 experiments of the program SJ-10, has been proposed to study local convection and heat transfer around an isolated growing vapor bubble during nucleate pool boiling on a well characterized flat surface in microgravity. An integrated micro heater has been developed. By using a local pulse overheating method in the experimental mode of single bubble boiling, a bubble nucleus can be excited with accurate spatial and temporal positioning on the top-side of a quartz glass substrate with a thickness of 2 mm and an effective heating area of 4.5 mm in diameter, and then grows under an approximate constant heat input provided by the main heater on the back-side of the substrate. Ten thin film micro-RTDs are used for local temperature measurements on the heating surface underneath the growing bubble. Normal pool boiling experiments can also be carried out with step-by-step increase of heating voltage. A series of ground test of the flight module of SOBER-SJ10 have been conducted. Good agreement of the measured data of single phase natural convection with the common-used empirical correlation warrants reasonable confidence in the data. It is found that the values of the incipience superheat of pool boiling at different subcooling are consistent with each others, verifying that the influence of subcooling on boiling incipience can be neglected. Pool boiling curves are also obtained, which shows great influence of subcooling on heat transfer of partial nucleate pool boiling, particularly in lower heat flux.

  18. Systems for heat and cold from the ground. Proposal for a development program; System foer vaerme och kyla ur mark - Foerslag till utvecklingsprogram

    Energy Technology Data Exchange (ETDEWEB)

    Rosen, Bengt; Gabrielsson, Anna; Fallsvik, Jan; Nilsson, Gunnel [Swedish Geotechnical Inst., Linkoeping (Sweden); Hellstroem, Goeran [Lund Inst. of Technology (Sweden). Dept. of Mathematical Physics

    2002-02-01

    Ground heat systems usually consist of a heat pump, with an evaporator connected to a heat carrier circuit of heat exchangers in the ground, and a condenser connected to the heat distribution system inside the building (radiators, fan convectors, floor heating etc). The heat pump's compressor is connected to the electricity grid. Similar systems without heat pumps are also used, where the excess heat from the building or process is exchanged with the cooler ground solely by circulation of the heat carrier fluid in the ground heat exchangers, so called 'Tree cooling'. The performance of ground heat systems depends on several factors. There is a continuous development of components and their interaction in heating/cooling systems, both in Sweden and abroad. Based on the current state of the art of ground heat systems and the national energy market it is possible to identify the development potential within many areas. In this report the development potentials for ground heat systems are presented in the following program areas: Combined heating/cooling systems with or without heat pumps and improvements of existing systems. Horizontal, compact and vertical ground heat exchangers, installation methods. Geological prerequisites and geotechnical impact of heating and/or cooling. Thermal capacity of all types of ground heat exchangers including moisture transport effects. Design specifications for different types of ground heat exchangers and ground conditions. Operation and maintenance. Environmental impact, e.g. of heat carrier fluids and local government environmental protection requirements. Economic optimization based on verified technical performance and cost figures.

  19. 浙北地区地源热泵土壤换热性能测试研究%Study on Measurement of Heat Transfer Characteristics of Ground Source in a Ground Source Heat Pump System in Northern Zhejiang

    Institute of Scientific and Technical Information of China (English)

    刘晓勤; 郑锦龙; 郑翀

    2011-01-01

    The heat transfer characteristics of ground source in Ground Source Heat Pump (GSHP) in Northem Zhejiang were experimentally measured. The experimental results showed that the initial ground source temperature in the coldest month was approximately 17.0℃, which was significantly higher than the temperature of the outside environment. The mean thermal conductivity of the ground source was 1.73W/(m· ℃). It indicated that the ground source had good heat transfer capacity and could be used for the ground source heat pump system. The experimental measurement of the heat transfer coefficient was also conducted on a single U type underground heat exchanger at the depth of 60 m. The experimental results showed that the heat dissipating capacity of the single pipe were 3666W in summer and 2508 W in winter, respectively. The heat dissipating capacity could meet the requirement of the ground source heat pump system.%对浙北地区某地源热泵工程土壤换热性能进行了实验测试,结果显示,浙北地区冬季最冷月地下土壤初始温度稳定在17.0℃左右,远高于室外环境温度;土壤的平均导热系数为1.73W/(m·℃),有较强的地下换热能力,适合做地源热泵系统;对60m深的单U形式地下换热器进行换热性能测试,夏季单根盘管散热量3666W,冬季单根盘管散热量2508W,能满足系统工作要求。

  20. Artificial Neural Networks: a viable tool to design heat load smoothing strategies for the ITER Toroidal Field coils

    Science.gov (United States)

    Froio, A.; Bonifetto, R.; Carli, S.; Quartararo, A.; Savoldi, L.; Zanino, R.

    2015-12-01

    In superconducting tokamaks, cryoplants provide the helium needed to cool the superconducting magnet systems. The evaluation of the heat load from the magnets to the cryoplant is fundamental for the design of the latter and the assessment of suitable strategies to smooth the heat load pulses induced by the pulsed plasma scenarios is crucial for the operation. Here, a simplified thermal-hydraulic model of an ITER Toroidal Field (TF) magnet, based on Artificial Neural Networks (ANNs), is developed and inserted into a detailed model of the ITER TF winding and casing cooling circuits based on the state-of-the-art 4C code, which also includes active controls. The low computational effort requested by such a model allows performing a fast parametric study, to identify the best smoothing strategy during standard plasma operation. The ANNs are trained using 4C simulations, and the predictive capabilities of the simplified model are assessed against 4C simulations, both with and without active smoothing, in terms of accuracy and computational time.

  1. Computational Fluid Dynamic Modeling of Horizontal Air-Ground Heat Exchangers (HAGHE for HVAC Systems

    Directory of Open Access Journals (Sweden)

    Paolo Maria Congedo

    2014-12-01

    Full Text Available In order to satisfy the requirements of Directive 2010/31/EU for Zero Energy Buildings (ZEB, innovative solutions were investigated for building HVAC systems. Horizontal air-ground heat exchangers (HAGHE offer a significant contribution in reducing energy consumption for ventilation, using the thermal energy stored underground, in order to pre-heat or pre-cool the ventilation air, in winter and summer, respectively. This is particularly interesting in applications for industrial, commercial and education buildings where keeping the indoor air quality under control is extremely important. Experimental measurements show that, throughout the year, the outside air temperature fluctuations are mitigated at sufficient ground depth (about 3 m because of the high thermal inertia of the soil, the ground temperature is relatively constant and instead higher than that of the outside air in winter and lower in summer. The study aims to numerically investigate the behavior of HAGHE by varying the air flow rate and soil conductivity in unsteady conditions by using annual weather data of South-East Italy. The analysis shows that, in warm climates, the HAGHE brings a real advantage for only a few hours daily in winter, while it shows significant benefits in the summer for the cooling of ventilation air up to several temperature degrees, already by a short pipe.

  2. Coiled-Coil Design: Updated and Upgraded.

    Science.gov (United States)

    Woolfson, Derek N

    2017-01-01

    α-Helical coiled coils are ubiquitous protein-folding and protein-interaction domains in which two or more α-helical chains come together to form bundles. Through a combination of bioinformatics analysis of many thousands of natural coiled-coil sequences and structures, plus empirical protein engineering and design studies, there is now a deep understanding of the sequence-to-structure relationships for this class of protein architecture. This has led to considerable success in rational design and what might be termed in biro de novo design of simple coiled coils, which include homo- and hetero-meric parallel dimers, trimers and tetramers. In turn, these provide a toolkit for directing the assembly of both natural proteins and more complex designs in protein engineering, materials science and synthetic biology. Moving on, the increased and improved use of computational design is allowing access to coiled-coil structures that are rare or even not observed in nature, for example α-helical barrels, which comprise five or more α-helices and have central channels into which different functions may be ported. This chapter reviews all of these advances, outlining improvements in our knowledge of the fundamentals of coiled-coil folding and assembly, and highlighting new coiled coil-based materials and applications that this new understanding is opening up. Despite considerable progress, however, challenges remain in coiled-coil design, and the next decade promises to be as productive and exciting as the last.

  3. Optimization of systems with the combination of ground-source heat pump and solar collectors in dwellings

    DEFF Research Database (Denmark)

    Kjellsson, Elisabeth; Hellström, Göran; Perers, Bengt

    2010-01-01

    The use of ground-source heat pumps for heating and domestic hot water in dwellings is common in Sweden. The combination with solar collectors has been introduced to reduce the electricity demand in the system. In order to analyze different systems with combinations of solar collectors and ground......-source heat pumps, computer simulations have been carried out with the simulation program TRNSYS. Large differences were found between the system alternatives. The optimal design is when solar heat produces domestic hot water during summertime and recharges the borehole during wintertime. The advantage...... is related to the rate of heat extraction from the borehole as well as the overall design of the system. The demand of electricity may increase with solar recharging, because of the increased operating time of the circulation pumps. Another advantage with solar heat in combination with heat pumps is when...

  4. Ground test program for a full-size solar dynamic heat receiver

    Science.gov (United States)

    Sedgwick, L. M.; Kaufmann, K. J.; McLallin, K. L.; Kerslake, T. W.

    Test hardware, facilities, and procedures were developed to conduct ground testing of a full-size, solar dynamic heat receiver in a partially simulated, low earth orbit environment. The heat receiver was designed to supply 102 kW of thermal energy to a helium and xenon gas mixture continuously over a 94 minute orbit, including up to 36 minutes of eclipse. The purpose of the test program was to quantify the receiver thermodynamic performance, its operating temperatures, and thermal response to changes in environmental and power module interface boundary conditions. The heat receiver was tested in a vacuum chamber using liquid nitrogen cold shrouds and an aperture cold plate. Special test equipment was designed to provide the required ranges in interface boundary conditions that typify those expected or required for operation as part of the solar dynamic power module on the Space Station Freedom. The support hardware includes an infrared quartz lamp heater with 30 independently controllable zones and a closed-Brayton cycle engine simulator to circulate and condition the helium-xenon gas mixture. The test article, test support hardware, facilities, and instrumentation developed to conduct the ground test program are all described.

  5. Case study for ARRA-funded ground-source heat pump (GSHP) demonstration at Oakland University

    Energy Technology Data Exchange (ETDEWEB)

    Im, Piljae [ORNL; Liu, Xiaobing [ORNL

    2015-09-01

    High initial costs and lack of public awareness of ground-source heat pump (GSHP) technology are the two major barriers preventing rapid deployment of this energy-saving technology in the United States. Under the American Recovery and Reinvestment Act (ARRA), 26 GSHP projects have been competitively selected and carried out to demonstrate the benefits of GSHP systems and innovative technologies for cost reduction and/or performance improvement. This paper highlights the findings of a case study of one of the ARRA-funded GSHP demonstration projects, a ground-source variable refrigerant flow (GS-VRF) system installed at the Human Health Building at Oakland University in Rochester, Michigan. This case study is based on the analysis of measured performance data, maintenance records, construction costs, and simulations of the energy consumption of conventional central heating, ventilation, and air-conditioning (HVAC) systems providing the same level of space conditioning as the demonstrated GS-VRF system. The evaluated performance metrics include the energy efficiency of the heat pump equipment and the overall GS-VRF system, pumping performance, energy savings, carbon emission reductions, and cost-effectiveness of the GS-VRF system compared with conventional HVAC systems. This case study also identified opportunities for reducing uncertainties in the performance evaluation, improving the operational efficiency, and reducing the installed cost of similar GSHP systems in the future.

  6. Analysis of the Effects of Vitiates on Surface Heat Flux in Ground Tests of Hypersonic Vehicles

    Science.gov (United States)

    Cuda, Vincent; Gaffney, Richard L

    2008-01-01

    To achieve the high enthalpy conditions associated with hypersonic flight, many ground test facilities burn fuel in the air upstream of the test chamber. Unfortunately, the products of combustion contaminate the test gas and alter gas properties and the heat fluxes associated with aerodynamic heating. The difference in the heating rates between clean air and a vitiated test medium needs to be understood so that the thermal management system for hypersonic vehicles can be properly designed. This is particularly important for advanced hypersonic vehicle concepts powered by air-breathing propulsion systems that couple cooling requirements, fuel flow rates, and combustor performance by flowing fuel through sub-surface cooling passages to cool engine components and preheat the fuel prior to combustion. An analytical investigation was performed comparing clean air to a gas vitiated with methane/oxygen combustion products to determine if variations in gas properties contributed to changes in predicted heat flux. This investigation started with simple relationships, evolved into writing an engineering-level code, and ended with running a series of CFD cases. It was noted that it is not possible to simultaneously match all of the gas properties between clean and vitiated test gases. A study was then conducted selecting various combinations of freestream properties for a vitiated test gas that matched clean air values to determine which combination of parameters affected the computed heat transfer the least. The best combination of properties to match was the free-stream total sensible enthalpy, dynamic pressure, and either the velocity or Mach number. This combination yielded only a 2% difference in heating. Other combinations showed departures of up to 10% in the heat flux estimate.

  7. Heat, chloride, and specific conductance as ground water tracers near streams

    Science.gov (United States)

    Cox, M.H.; Su, G.W.; Constantz, J.

    2007-01-01

    Commonly measured water quality parameters were compared to heat as tracers of stream water exchange with ground water. Temperature, specific conductance, and chloride were sampled at various frequencies in the stream and adjacent wells over a 2-year period. Strong seasonal variations in stream water were observed for temperature and specific conductance. In observation wells where the temperature response correlated to stream water, chloride and specific conductance values were similar to stream water values as well, indicating significant stream water exchange with ground water. At sites where ground water temperature fluctuations were negligible, chloride and/or specific conductance values did not correlate to stream water values, indicating that ground water was not significantly influenced by exchange with stream water. Best-fit simulation modeling was performed at two sites to derive temperature-based estimates of hydraulic conductivities of the alluvial sediments between the stream and wells. These estimates were used in solute transport simulations for a comparison of measured and simulated values for chloride and specific conductance. Simulation results showed that hydraulic conductivities vary seasonally and annually. This variability was a result of seasonal changes in temperature-dependent hydraulic conductivity and scouring or clogging of the streambed. Specific conductance fits were good, while chloride data were difficult to fit due to the infrequent (quarterly) stream water chloride measurements during the study period. Combined analyses of temperature, chloride, and specific conductance led to improved quantification of the spatial and temporal variability of stream water exchange with shallow ground water in an alluvial system. ?? 2007 National Ground Water Association.

  8. The summary of heat transfer performance influential analysis of Ground Source Heat Pump' s vertical ground heat exchangers%地源热泵垂直地埋管传热性能影响因子分析

    Institute of Scientific and Technical Information of China (English)

    赵丽博; 段飞; 李政

    2011-01-01

    The design of Ground Source Heat Pump' s (GSHP) ground heat exchanger is the key and difficulty of GSHP system' s engineering applications. Combining the research results at home and abroad in recent years, this article analysis completely the influence of backfill material, buried tube depth, the flow in pipe and other factors on the performance of ground heat exchangers, aiming at providing the basis for engineering applications and scientific research.%地源热泵地下换热器的设计是地源热泵系统工程应用的关键和难点,结合近几年国内外的研究成果,全面分析了管内流量、埋管深度、回填材料等因子对地埋管传热性能的影响,以期为工程应用及科学研究提供依据。

  9. Heating coil welding technique for connection of large-diameter PE pipes using universally applicable, flexible taped joints; Heizwendelschweissverfahren fuer die Verbindung von PE-Grossrohren mittels universal anwendbarer, flexibler Wickelmuffen

    Energy Technology Data Exchange (ETDEWEB)

    Baudrit, Benjamin; Kraus, Eduard; Heidemeyer, Peter; Bastian, Martin [Sueddeutsche Kunststoff-Zentrum, Wuerzburg (Germany); Kern, Juergen; Neufeld, Wjatscheslaw [Frank und Krah Wickelrohr GmbH, Woelfersheim (Germany)

    2011-07-01

    This research project (Heating coil welding technique for connection of large-diameter PE pipes using universally applicable, flexible taped joints) was carried out by SKZ (Sueddeutsches Kunststoff-Zentrum) in close coopearation with Messrs. Frank and Krah Wickelrohr GmbH with the intention to develop a high-quality, economically efficient joining process for large-diameter pipes. The technique is based on the new technology of heating coil joints which permits the use of any desired joint geometries at acceptable cost. The new technique was validated for joints up to a diameter of 1,000 mm. With the welding parameters calculated in the project, even larger diameter joints are possible in theory.

  10. Horizontal Air-Ground Heat Exchanger Performance and Humidity Simulation by Computational Fluid Dynamic Analysis

    Directory of Open Access Journals (Sweden)

    Paolo Maria Congedo

    2016-11-01

    Full Text Available Improving energy efficiency in buildings and promoting renewables are key objectives of European energy policies. Several technological measures are being developed to enhance the energy performance of buildings. Among these, geothermal systems present a huge potential to reduce energy consumption for mechanical ventilation and cooling, but their behavior depending on varying parameters, boundary and climatic conditions is not fully established. In this paper a horizontal air-ground heat exchanger (HAGHE system is studied by the development of a computational fluid dynamics (CFD model. Summer and winter conditions representative of the Mediterranean climate are analyzed to evaluate operation and thermal performance differences. A particular focus is given to humidity variations as this parameter has a major impact on indoor air quality and comfort. Results show the benefits that HAGHE systems can provide in reducing energy consumption in all seasons, in summer when free-cooling can be implemented avoiding post air treatment using heat pumps.

  11. Field synergy theory based convective heat transfer in an enhanced tube with multiple spiral coils%基于场协同的多叶螺旋线圈强化管内对流换热研究

    Institute of Scientific and Technical Information of China (English)

    金光; 王正文; 田瑞; 于晔

    2015-01-01

    To solve the prominent problem of convective heat transfer enhancement in solar collector tubes, experimental investigation on enhancing heat transfer between tube well and medium by copper inserts with double multiple spiral coils and three multiple spiral coils was conducted,by using field synergy theory.The results show that,the convective field synergy number Fc increases sharply with the synergy angle cosine cosβin the multiple spiral coils tubes.Moreover,the velocity field and temperature field also show a good cooperativity.The working fluid with three spiral coils has the best comprehensive heat trans-fer performance,under the condition with constant heat flow (240

  12. Modeling a Helical-coil Steam Generator in RELAP5-3D for the Next Generation Nuclear Plant

    Energy Technology Data Exchange (ETDEWEB)

    Nathan V. Hoffer; Piyush Sabharwall; Nolan A. Anderson

    2011-01-01

    Options for the primary heat transport loop heat exchangers for the Next Generation Nuclear Plant are currently being evaluated. A helical-coil steam generator is one heat exchanger design under consideration. Safety is an integral part of the helical-coil steam generator evaluation. Transient analysis plays a key role in evaluation of the steam generators safety. Using RELAP5-3D to model the helical-coil steam generator, a loss of pressure in the primary side of the steam generator is simulated. This report details the development of the steam generator model, the loss of pressure transient, and the response of the steam generator primary and secondary systems to the loss of primary pressure. Back ground on High Temperature Gas-cooled reactors, steam generators, the Next Generation Nuclear Plant is provided to increase the readers understanding of the material presented.

  13. Case Study for the ARRA-Funded Ground Source Heat Pump Demonstration at Ball State University

    Energy Technology Data Exchange (ETDEWEB)

    Im, Piljae [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Liu, Xiaobing [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Henderson, Jr., Hugh [CDH Energy Corp., Beijing (China)

    2016-12-01

    With funding provided by the American Recovery and Reinvestment Act (ARRA), 26 ground-source heat pump (GSHP) projects were competitively selected in 2009 to demonstrate the benefits of GSHP systems and innovative technologies for cost reduction and/or performance improvement. One of the selected demonstration projects is a district central GSHP system installed at Ball State University (BSU) in Muncie, IN. Prior to implementing the district GSHP system, 47 major buildings in BSU were served by a central steam plant with four coal-fired and three natural-gas-fired steam boilers. Cooling was provided by five water-cooled centrifugal chillers at the District Energy Station South (DESS). The new district GSHP system replaced the existing coal-fired steam boilers and conventional water-cooled chillers. It uses ground-coupled heat recovery (HR) chillers to meet the simultaneous heating and cooling demands of the campus. The actual performance of the GSHP system was analyzed based on available measured data from August 2015 through July 2016, construction drawings, maintenance records, personal communications, and construction costs. Since Phase 1 was funded in part by the ARRA grant, it is the focus of this case study. The annual energy consumption of the GSHP system was calculated based on the available measured data and other related information. It was compared with the performance of a baseline scenario— a conventional water-cooled chiller and natural-gas-fired boiler system, both of which meet the minimum energy efficiencies allowed by the American Society of Heating, Refrigerating and Air-Conditioning Engineers (ASHRAE 90.1-2013). The comparison was made to determine source energy savings, energy cost savings, and CO2 emission reductions achieved by the GSHP system. A cost analysis was performed to evaluate the simple payback of the GSHP system. The following sections summarize the results of the analysis, the lessons learned, and recommendations for improvement

  14. A New Comparison Of Vertical Ground Heat Exchanger Design Methods For Residential Applications

    Energy Technology Data Exchange (ETDEWEB)

    Shonder, John A [ORNL; Baxter, David V [ORNL; Thornton, Jeff W. [Thermal Energy Systems Specialists, Inc.; Hughes, Patrick [ORNL

    1999-06-01

    A previous comparison of vertical ground heat exchanger design methods for geothermal heat pumps in residential applications found large disagreements in the sizes recommended by five commercially-available computer programs, even when consistent information was input to all five. The objective of this work is to repeat the comparison using updated versions of the five programs originally tested, and one new program which was not included in the previous comparison. Simulation models of two sites - one in a cooling dominated climate, and the other in a heating dominated climate - were calibrated to site-collected data and then driven with typical meteorological year data to produce consistent inputs for the six design programs. The results indicate that the programs are now much more consistent with one another. For the cooling dominated site, design lengths vary by about {+-}8%, and for the heating dominated site the design lengths vary by {+-}16%. Compared to the tests performed in 1996, there is now much more consistency among the various design algorithms.

  15. Experimental studies on heat transfer and friction factor characteristics of Al{sub 2}O{sub 3}/water nanofluid in a circular pipe under laminar flow with wire coil inserts

    Energy Technology Data Exchange (ETDEWEB)

    Chandrasekar, M.; Suresh, S. [Department of Mechanical Engineering, National Institute of Technology, Tiruchirappalli 620015 (India); Chandra Bose, A. [Nanomaterials Laboratory, Department of Physics, National Institute of Technology, Tiruchirappalli 620015 (India)

    2010-02-15

    In this paper, fully developed laminar flow convective heat transfer and friction factor characteristics of Al{sub 2}O{sub 3}/water nanofluid flowing through a uniformly heated horizontal tube with and without wire coil inserts is presented. For this purpose, Al{sub 2}O{sub 3} nanoparticles of 43 nm size were synthesized, characterized and dispersed in distilled water to form stable suspension containing 0.1% volume concentration of nanoparticles. The Nusselt number in the fully developed region were measured and found to increase by 12.24% at Re = 2275 for plain tube with nanofluid compared to distilled water. Two wire coil inserts made of stainless steel with pitch ratios 2 and 3 were used which increased the Nusselt numbers by 15.91% and 21.53% respectively at Re = 2275 with nanofluid compared to distilled water. The better heat transfer performance of nanofluid with wire coil insert is attributed to the effects of dispersion or back-mixing which flattens the temperature distribution and make the temperature gradient between the fluid and wall steeper. The measured pressure loss with the use of nanofluids is almost equal to that of the distilled water. The empirical correlations developed for Nusselt number and friction factor in terms of Reynolds/Peclet number, pitch ratio and volume concentration fits with the experimental data within {+-}15%. (author)

  16. Designing Stable Antiparallel Coiled Coil Dimers

    Institute of Scientific and Technical Information of China (English)

    曾宪纲; 周海梦

    2001-01-01

    The history of antiparallel coiled coil dimer design is briefly reviewed and the main principles governing the successful designs are explained. They include analysis of the inter-subunit electrostatic repulsion for determining partners for dimerization and of the buried polar interaction for determining the relative orientation of the partners. A theory is proposed to explain the lack of antiparallel coiled coil homodimers in nature.

  17. Simplified heat exchange model of fan coil in wet cooling conditions%适用于湿工况的风机盘管简化换热模型

    Institute of Scientific and Technical Information of China (English)

    凌飞; 杨春节

    2012-01-01

    针对半集中式空调系统风机盘管的换热计算问题,通过干湿工况转换方法,设计了一种适用于湿工况的风机盘管换热模型.根据能量平衡和热传递原理,简化了该换热模型,使换热量仅由冷水流量、进水温度、盘管风量和进风温度等独立控制变量确定.在实际风机盘管上进行了仿真验证,得到了不同工作条件下的换热曲线.实验结果表明,该简化换热模型计算精度较高.%To solve the heat exchange calculation problem of the fan coil in the semi-centralized air conditioning system, through a wet-dry switching method, designs a heat transfer model of the fan coil for wet cooling conditions. Based on the energy balance and heat transfer principles, simplifies the heat transfer model in which the heat exchange capacity can be simply determined by the chilled water flow rate, temperature of supply chilled water, and flow rate and temperature of supply air as independent variables. By means of a fan coil unit simulation test, obtains the heat exchange curves in different conditions. The result shows a higher accuracy of model.

  18. ITER Side Correction Coil Quench model and analysis

    Science.gov (United States)

    Nicollet, S.; Bessette, D.; Ciazynski, D.; Duchateau, J. L.; Gauthier, F.; Lacroix, B.

    2016-12-01

    Previous thermohydraulic studies performed for the ITER TF, CS and PF magnet systems have brought some important information on the detection and consequences of a quench as a function of the initial conditions (deposited energy, heated length). Even if the temperature margin of the Correction Coils is high, their behavior during a quench should also be studied since a quench is likely to be triggered by potential anomalies in joints, ground fault on the instrumentation wires, etc. A model has been developed with the SuperMagnet Code (Bagnasco et al., 2010) for a Side Correction Coil (SCC2) with four pancakes cooled in parallel, each of them represented by a Thea module (with the proper Cable In Conduit Conductor characteristics). All the other coils of the PF cooling loop are hydraulically connected in parallel (top/bottom correction coils and six Poloidal Field Coils) are modeled by Flower modules with equivalent hydraulics properties. The model and the analysis results are presented for five quench initiation cases with/without fast discharge: two quenches initiated by a heat input to the innermost turn of one pancake (case 1 and case 2) and two other quenches initiated at the innermost turns of four pancakes (case 3 and case 4). In the 5th case, the quench is initiated at the middle turn of one pancake. The impact on the cooling circuit, e.g. the exceedance of the opening pressure of the quench relief valves, is detailed in case of an undetected quench (i.e. no discharge of the magnet). Particular attention is also paid to a possible secondary quench detection system based on measured thermohydraulic signals (pressure, temperature and/or helium mass flow rate). The maximum cable temperature achieved in case of a fast current discharge (primary detection by voltage) is compared to the design hot spot criterion of 150 K, which includes the contribution of helium and jacket.

  19. An Experimental Facility to Validate Ground Source Heat Pump Optimisation Models for the Australian Climate

    Directory of Open Access Journals (Sweden)

    Yuanshen Lu

    2017-01-01

    Full Text Available Ground source heat pumps (GSHPs are one of the most widespread forms of geothermal energy technology. They utilise the near-constant temperature of the ground below the frost line to achieve energy-efficiencies two or three times that of conventional air-conditioners, consequently allowing a significant offset in electricity demand for space heating and cooling. Relatively mature GSHP markets are established in Europe and North America. GSHP implementation in Australia, however, is limited, due to high capital price, uncertainties regarding optimum designs for the Australian climate, and limited consumer confidence in the technology. Existing GSHP design standards developed in the Northern Hemisphere are likely to lead to suboptimal performance in Australia where demand might be much more cooling-dominated. There is an urgent need to develop Australia’s own GSHP system optimisation principles on top of the industry standards to provide confidence to bring the GSHP market out of its infancy. To assist in this, the Queensland Geothermal Energy Centre of Excellence (QGECE has commissioned a fully instrumented GSHP experimental facility in Gatton, Australia, as a publically-accessible demonstration of the technology and a platform for systematic studies of GSHPs, including optimisation of design and operations. This paper presents a brief review on current GSHP use in Australia, the technical details of the Gatton GSHP facility, and an analysis on the observed cooling performance of this facility to date.

  20. Characterization of Site for Installing Open Loop Ground Source Heat Pump System

    Science.gov (United States)

    Yun, S. W.; Park, Y.; Lee, J. Y.; Yi, M. J.; Cha, J. H.

    2014-12-01

    This study was conducted to understand hydrogeological properties of site where open loop ground source heat pump system will be installed and operated. Groundwater level and water temperature were hourly measured at the well developed for usage of open loop ground source heat pump system from 11 October 2013 to 8 January 2014. Groundwater was sampled in January and August 2013 and its chemical and isotopic compositions were analyzed. The bedrock of study area is the Jurassic granodiorite that mainly consists of quartz (27.9 to 46.8%), plagioclase (26.0 to 45.5%), and alkali feldspar (9.5 to 18.7%). The groundwater level ranged from 68.30 to 68.94 m (above mean sea level). Recharge rate was estimated using modified watertable fluctuation method and the recharge ratios was 9.1%. The water temperature ranged from 14.8 to 15.0oC. The vertical Increase rates of water temperature were 1.91 to 1.94/100 m. The water temperature showed the significant seasonal variation above 50 m depth, but had constant value below 50 m depth. Therefore, heat energy of the groundwater can be used securely in open loop ground source heat pump system. Electrical conductivity ranged from 120 to 320 µS/cm in dry season and from 133 to 310 µS/cm in wet season. The electrical conductivity gradually decreased with depth. In particular, electrical conductivity in approximately 30 m depth decreased dramatically (287 to 249 µS/cm) in wet season. The groundwater was Ca-HCO3 type. The concentrations of dissolved components did not show the vertically significant variations from 0 to 250 m depth. The δ18O and δD ranged from -9.5 to -9.4‰ and from -69 to -68‰. This work is supported by the New and Renewable Energy of the Korea Institute of Energy Technology Evaluation and Planning (KETEP) grant funded by the Korea government Ministry of Knowledge Economy (No.20123040110010).

  1. Thermal ground-water discharge and associated convective heat flux, Bruneau-Grand View area, southwest Idaho

    Science.gov (United States)

    Young, H.W.; Lewis, R.E.; Backsen, R.L.

    1979-01-01

    The Bruneau-Grand View area occupies about 1,100 square miles in southwest Idaho. The area has a rural population dependent on ground-water irrigation. Temperature of the ground water ranges from 15 C to more than 80 C. Ground water for irrigation is obtained from flowing and pumped wells. Discharge of thermal ground water from 104 irrigation wells and from 5 hot springs in 1978 was about 50,500 acre-feet. Convective heat flux from the geothermal system associated with this discharge was 4.97 x 10 to the 7th power calories per second. (Woodard-USGS)

  2. 微波加热技术在钛带卷酸洗及脱脂过程中的应用%Application of Pickling and Degreasing Titanium Strip Coil based on Microwave Heating Technology

    Institute of Scientific and Technical Information of China (English)

    常军; 郭胜惠; 彭金辉; 杨彪; 苏鹤洲; 史亚鸣

    2013-01-01

    In the present, the application of conventional heating method and its problems for the pickler and degrea-ser in titanium strip coil production process were described, and also introduced the principles and the advantages of microwave heating acid and alkali. Pilot experiment with self - developed microwave heating device show that the thermal efficiency values of both NaOH solution and acid can be above 70%. The results show that the microwave heating technology can be applied to the titanium strip coil pickling industrial. Finally, the development prospect of microwave heating technology in the titanium industry was presented.%针对钛带卷生产工艺过程中加热酸洗液和脱脂液常规方法的不足,分析了微波加热的原理及优势,并利用自主研制的微波流体加热设备,对微波加热酸洗液和脱脂液进行了中试实验.研究得出,微波加热酸洗液和脱脂液的热效率值均在70%以上.举例说明了微波加热技术在钛带卷酸洗工业化应用情况,并展望了微波加热技术在钛产业中的推广前景.

  3. Future Residential Water Heating Prospects in Brazil: A Scenario Building Ground Analysis

    Directory of Open Access Journals (Sweden)

    Felipe de Albuquerque Sgarbi

    2014-12-01

    Full Text Available In Brazil, electricity is the prime energy carrier for bath shower heating purposes. However, since analyses indicate that expansion of the country´s electricity generation capacity shall spruce from an increased non-renewable sources’ stake in detriment to that of hydroelectricity, high electricity consumption rates that spring from home end uses of the kind have drawn the attention of those who are involved with local energy planning. Furthermore, massive use of electric showers in a short timeframe largely drive electricity demands to culminate in peak loads. For water heating purposes, this context has favoured an alternative to electricity, deemed feasible from both an efficiency and energy infrastructure standpoint: promote fuel gas consumption (liquefied petroleum gas and natural gas in particular. A scenario methodology is herein employed to map electric shower use related variables and players and assess the future behaviour of the core elements that condition resorting to this technology. Thereafter, strategies and opportunities to promote the rational consumption of the country´s power sources ground on the increased use of fuel gases for residential water heating purposes are discussed. 

  4. Hybrid Ground-Source Heat Pump Installations: Experiences, Improvements, and Tools

    Energy Technology Data Exchange (ETDEWEB)

    Scott Hackel; Amanda Pertzborn

    2011-06-30

    One innovation to ground-source heat pump (GSHP, or GHP) systems is the hybrid GSHP (HyGSHP) system, which can dramatically decrease the first cost of GSHP systems by using conventional technology (such as a cooling tower or a boiler) to meet a portion of the peak heating or cooling load. This work uses three case studies (two cooling-dominated, one heating-dominated) to demonstrate the performance of the hybrid approach. Three buildings were studied for a year; the measured data was used to validate models of each system. The models were used to analyze further improvements to the hybrid approach, and establish that this approach has positive impacts, both economically and environmentally. Lessons learned by those who design and operate the systems are also documented, including discussions of equipment sizing, pump operation, and cooling tower control. Finally, the measured data sets and models that were created during this work are described; these materials have been made freely available for further study of hybrid systems.

  5. Focus group discussions among owners and non-owners of ground source heat pumps

    Energy Technology Data Exchange (ETDEWEB)

    Roberson, B.F.

    1988-07-01

    This research was sponsored by the Office of Buildings and Community Systems and conducted by the Pacific Northwest Laboratory as part of an ongoing effort to enhance the commercial use of federally developed technology. Federal dollars have supported research on the development of ground source heat pumps (GSHP) for several years. Though several companies currently sell GSHP's for residential use, their share of the total heating and air conditioning business remains less than one percent. Large manufacturing companies with national distribution have not yet added GSHP equipment to their product line. GSHP's use only about one half (Braud 1987) to one third (Bose 1987) of the energy needed to operate conventional furnaces and air conditioners. Consequently, a high level of market penetration by the GSHP offers direct benefits to both utility companies and individual users of the systems. Widespread use of these highly efficient systems will reduce both total energy consupmtion, and problems associated with high levels of energy use during peak periods. This will allow utility companies to delay capital expenditures for new facilities to meet the growing energy demand during peak periods. The cost effective use of electricity also reduces the likelihood of homeowners switching to a different fuel source for heating. 5 refs.

  6. Optimization of activator solution and heat treatment of ground lignite type fly ash geopolymers

    Science.gov (United States)

    Molnár, Z.; Szabó, R.; Rácz, Á.; Lakatos, J.; Debreczeni, Á.; Mucsi, G.

    2017-02-01

    Geopolymers are inorganic polymers which can be produced by the reaction between silico aluminate oxides and alkali silicates in alkaline medium. Materialscontaining silica and alumina compounds are suitable for geopolymer production. These can beprimary materials or industrial wastes, i. e. fly ash, metallurgical slag and red mud. In this paper, the results of the systematic experimental series are presented which were carried out in order to optimize the geopolymer preparation process. Fly ash was ground for different residence time (0, 5, 10, 30, 60 min) in order to investigate the optimal specific surface area. NaOH activator solution concentration also varied (6, 8, 10, 12, 14 M). Furthermore, sodium silicate was added to NaOH as a network builder solution. In this last serie different heat curing temperatures (30, 60, 90°C) were also applied. After seven days of ageing the physical properties of the geopolymer(compressive strength and specimen density)were measured. Chemical leaching tests on the rawmaterial and the geopolymers were carried out to determine the elements which can be mobilized by different leaching solutions. It was found that the above mentioned parameters (fly ash fineness, molar concentration and composition of activator solution, heat curing) has great effect on the physical and chemical properties of geopolymer specimens. Optimal conditions were as follows: specific surface area of the fly ash above 2000 cm2/g, 10 M NaOH, 30°C heat curing temperature which resulted in 21 MPa compressive strength geopolymer.

  7. Modeling of Rocket Fuel Heating and Cooling Processes in the Interior Receptacle Space of Ground-Based Systems

    Directory of Open Access Journals (Sweden)

    K. I. Denisova

    2016-01-01

    Full Text Available The propellant to fill the fuel tanks of the spacecraft, upper stages, and space rockets on technical and ground-based launch sites before fueling should be prepared to ensure many of its parameters, including temperature, in appropriate condition. Preparation of fuel temperature is arranged through heating and cooling the rocket propellants (RP in the tanks of fueling equipment. Processes of RP temperature preparation are the most energy-intensive and timeconsuming ones, which require that a choice of sustainable technologies and modes of cooling (heating RP provided by the ground-based equipment has been made through modeling of the RP [1] temperature preparation processes at the stage of design and operation of the groundbased fueling equipment.The RP temperature preparation in the tanks of the ground-based systems can be provided through the heat-exchangers built-in the internal space and being external with respect to the tank in which antifreeze, air or liquid nitrogen may be used as the heat transfer media. The papers [1-12], which note a promising use of the liquid nitrogen to cool PR, present schematic diagrams and modeling systems for the RP temperature preparation in the fueling equipment of the ground-based systems.We consider the RP temperature preparation using heat exchangers to be placed directly in RP tanks. Feeding the liquid nitrogen into heat exchanger with the antifreeze provides the cooling mode of PR while a heated air fed there does that of heating. The paper gives the systems of equations and results of modeling the processes of RP temperature preparation, and its estimated efficiency.The systems of equations of cooling and heating RP are derived on the assumption that the heat exchange between the fuel and the antifreeze, as well as between the storage tank and the environment is quasi-stationary.The paper presents calculation results of the fuel temperature in the tank, and coolant temperature in the heat exchanger, as

  8. Modelling of Shaded and Unshaded Shallow-Ground Heat Pump System for a Residential Building Block in a Mediterranean Climate

    Science.gov (United States)

    Bottarelli, M.; Yousif, C.

    2017-01-01

    Heat pumps may be coupled to shallow-ground geothermal fields and used for the purpose of space heating and cooling of buildings. However, quite often it is not possible to locate the geothermal field in cleared grounds, especially in cities where building density is high and land has a high premium. This leads to the possibility of burying the geothermal field under the basement of new building blocks, before construction of the building. In the present work, the shaded-unshaded arrangement is numerically studied by coupling the software DesignBuilder-EnergyPlus to assess the building’s energy requirement with the software FEFLOW to solve the heat transfer equation in porous media. Assuming a standard residential building block, the coupling between the two software is performed by assigning the thermal energy requirement for air conditioning, as calculated by EnergyPlus, to a flat-panel typology of ground heat exchanger simplified in a 2D FEFLOW’s domain. The results show that it is necessary to opt for a dual-source heat pump (air/geothermal) system to ensure that the ground is not frozen or over-heated at peak times and to improve the overall performance of the system.

  9. Design and Testing of Coils for Pulsed Electromagnetic Forming

    OpenAIRE

    Golovashchenko, S.; Bessonov, N.; Davies, R

    2006-01-01

    Coil design influences the distribution of electromagnetic forces applied to both the blank and the coil. The required energy of the process is usually defined by deformation of the blank. However, the discharge also results in a significant amount of heat being generated and accumulating in the coil. Therefore, EMF process design involves working with three different problems: 1) propagation of an electromagnetic field through the coil-blank system and generation of pulsed electromagnetic pr...

  10. Switching transients in a superconducting coil

    Energy Technology Data Exchange (ETDEWEB)

    Owen, E.W.; Shimer, D.W.

    1983-11-18

    A study is made of the transients caused by the fast dump of large superconducting coils. Theoretical analysis, computer simulation, and actual measurements are used. Theoretical analysis can only be applied to the simplest of models. In the computer simulations two models are used, one in which the coil is divided into ten segments and another in which a single coil is employed. The circuit breaker that interrupts the current to the power supply, causing a fast dump, is represented by a time and current dependent conductance. Actual measurements are limited to measurements made incidental to performance tests on the MFTF Yin-yang coils. It is found that the breaker opening time is the critical factor in determining the size and shape of the transient. Instantaneous opening of the breaker causes a lightly damped transient with large amplitude voltages to ground. Increasing the opening time causes the transient to become a monopulse of decreasing amplitude. The voltages at the external terminals are determined by the parameters of the external circuit. For fast opening times the frequency depends on the dump resistor inductance, the circuit capacitance, and the amplitude on the coil current. For slower openings the dump resistor inductance and the current determine the amplitude of the voltage to ground at the terminals. Voltages to ground are less in the interior of the coil, where transients related to the parameters of the coil itself are observed.

  11. Starch gelatinization in coiled heaters.

    Science.gov (United States)

    Kelder, J D H; Ptasinski, K J; Kerkhof, P J A M

    2004-01-01

    A gelatinizing model food derived from a 5% w/w cross-linked waxy maize starch suspension was simulated in coiled heaters to assess the impact of centrifugal forces on flow and heat transfer. For four coil diameters (D = 0.25, 1, 2.5, and infinity m) and three flow rates (w = 0.5, 1, and 2 m/s), heat transfer, viscous development, and the severity of channeling were evaluated. Increasing curvature proved to suppress channeling as a result of more uniform heating and gelatinization. The maximum attainable viscosity was also higher, implying a lower starch consumption for a target viscosity. Higher flow rates necessitated longer heaters, and the maximum viscosity decreased. Moderate product velocities are therefore recommended.

  12. 内置螺旋线圈换热管换热分析及数值模拟%Thermal Analysis and Numerical Simulation for Heat Exchange Tube with Wire Coil Internally Installed

    Institute of Scientific and Technical Information of China (English)

    徐志明; 刘枫; 朱宏娟

    2014-01-01

    概述了螺旋线圈装置的强化传热原理。通过建立光管和内置螺旋线圈换热管的三维流动模型,利用Fluent软件以黏性流体变压器油为研究对象对换热管内速度场、温度场、压力场以及换热过程进行了数值模拟。对比两种模拟结果表明,内置螺旋线圈的换热管内流体流动比较复杂,流体在近壁面处呈明显的螺旋流动,流体的径向速度和切向速度都有提高。总的来说,换热管内布置了螺旋线圈以后流体在其中的流动比在光管内有更强的湍流度,且能够打破流体的速度边界层,增强了流体的对流换热,极大提高了传热系数。%The strengthening heat transfer principle of the wire coil equipment is summarized. The three-di-mensional simulation of the plain tube and heat exchange tube with wire coil has been performed using the FLUENT software. The velocity,temperature and pressure distribution as well as thermal process is obtained. The results showed that the flow characteristics in the heat exchange tube with wire coil was more complex than that in the plain one and the fluid near the wall presented apparent spiral flow. Meanwhile,the radial and tan-gential velocity both increased obviously. In general,the turbulence intensity was strengthened in the heat ex-change tube with wire coil. Moreover,the velocity boundary layer was broken,and the heat convection was en-hanced. So,the heat coefficient was improved tremendously.

  13. Regulatory framework and examples of ground-source heating/cooling technology in the Winnipeg area

    Energy Technology Data Exchange (ETDEWEB)

    Matthews, R. [Manitoba Conservation, Winnipeg, MB (Canada)

    2003-07-01

    Winnipeg, Manitoba lies over a highly transmissive Carbonate Aquifer of Ordovician age, which provides a suitable environment for groundwater supply and return wells. Many licensed ground-source heating cooling (GSHC) systems have been installed in and around the Winnipeg urban area over the last several decades. A water rights licence, issued by the Provincial Department of Conservation, is required for all groundwater supply and return wells. This licence comes with certain rights and responsibilities. This paper describes the regulatory framework which governs the licensing process. The author emphasized that the future use and success of the technology depends, in large part, on the development of a critical mass of experienced contractors, hydrogeologists and consulting engineers. 2 refs.

  14. Thermal Energy Storage in the Ground of a Greenhouse by the Polypropylene Capillary Heat Exchanger

    Directory of Open Access Journals (Sweden)

    M. Lazâar

    2008-01-01

    Full Text Available The problem of temperature inversion is one of solar origin principal problems about which the cultures under shelters complain. Indeed, for the winter period, the temperature under greenhouse is very low at night and it is rather high during the day in summer. Consequently, the heating of the greenhouses is essential. In this work, we studied the advisability of using two exchangers coupled between them to manage thermal energy in a greenhouse. The first system is a battery of plaits with capillary tubes buried under ground with a depth of 70 cm. The second is an air exchanger based on plastic tubes black known as agrotherms suspended with two meters and half height. The hot water, which circulates in the exchangers, is provided by the hot-water tank of the electro-solar power station of the Center of Energy Researches and Technologies (CRTEn from Tunisia.

  15. Ground-water heat pumps: an examination of hydrogeologic, environmental, legal, and economic factors affecting their use

    Energy Technology Data Exchange (ETDEWEB)

    Armitage, D M; Bacon, D J; Massey-Norton, J T; Miller, J D

    1980-11-12

    Groundwater is attractive as a potential low-temperature energy source in residential space-conditioning applications. When used in conjuncton with a heat pump, ground water can serve as both a heat source (for heating) and a heat sink (for cooling). Major hydrogeologic aspects that affect system use include groundwater temperature and availability at shallow depths as these factors influence operational efficiency. Ground-water quality is considered as it affects the performance and life-expectancy of the water-side heat exchanger. Environmental impacts related to groundwater heat pump system use are most influenced by water use and disposal methods. In general, recharge to the subsurface (usually via injection wells) is recommended. Legal restrictions on system use are often stricter at the municipal and county levels than at state and Federal levels. Although Federal regulations currently exist, the agencies are not equipped to regulate individual, domestic installations. Computer smulations indicate that under a variety of climatologic conditions, groundwater heat pumps use less energy than conventional heating and cooling equipment. Life-cycle cost comparisons with conventional equipment depend on alternative system choices and well cost options included in the groundwater heat pump system.

  16. Numerical Study on the Impact of Ground Heating and Ambient Wind Speed on Flow Fields in Street Canyons

    Institute of Scientific and Technical Information of China (English)

    LI Lei; YANG Lin; ZHANG Li-Jie; JIANG Yin

    2012-01-01

    The impact of ground heating on flow fields in street canyons under different ambient wind speed conditions was studied based on numerical methods.A series of numerical tests were performed,and three factors including height-to-width (H/W) ratio,ambient wind speed and ground heating intensity were taken into account.Three types of street canyon with H/W ratios of 0.5,1.0 and 2.0,respectively,were used in the simulation and seven speed values ranging from 0.0 to 3.0 m s-1 were set for the ambient wind speed.The ground heating intensity,which was defined as the difference between the ground temperature and air temperature,ranged from 10 to 40 K with an increase of 10 K in the tests.The results showed that under calm conditions,ground heating could induce circulation with a wind speed of around 1.0 m s-1,which is enough to disperse pollutants in a street canyon.It was also found that an ambient wind speed threshold may exist for street canyons with a fixed H/W ratio.When ambient wind speed was lower than the threshold identified in this study,the impact of the thermal effect on the flow field was obvious,and there existed a multi-vortex flow pattern in the street canyon.When the ambient wind speed was higher than the threshold,the circulation pattern was basically determined by dynamic effects.The tests on the impact of heating intensity showed that a higher ground heating intensity could strengthen the vortical flow within the street canyon,which would help improve pollutant diffusion capability in street canyons.

  17. Geothermal(Ground-Source)Heat Pumps: Market Status, Barriers to Adoption, and Actions to Overcome Barriers

    Energy Technology Data Exchange (ETDEWEB)

    Hughes, Patrick [ORNL

    2008-12-01

    More effective stewardship of our resources contributes to the security, environmental sustainability, and economic well-being of the nation. Buildings present one of the best opportunities to economically reduce energy consumption and limit greenhouse gas emissions. Geothermal heat pumps (GHPs), sometimes called ground-source heat pumps, have been proven capable of producing large reductions in energy use and peak demand in buildings. However, GHPs have received little attention at the policy level as an important component of a national strategy. Have policymakers mistakenly overlooked GHPs, or are GHPs simply unable to make a major contribution to the national goals for various reasons? This brief study was undertaken at DOE's request to address this conundrum. The scope of the study includes determining the status of global GHP markets and the status of the GHP industry and technology in the United States, assembling previous estimates of GHP energy savings potential, identifying key barriers to application of GHPs, and identifying actions that could accelerate market adoption of GHPs. The findings are documented in this report along with conclusions and recommendations.

  18. Ground heat flux: An analytical review of 6 models evaluated at 88 sites and globally

    Science.gov (United States)

    Purdy, A. J.; Fisher, J. B.; Goulden, M. L.; Famiglietti, J. S.

    2016-12-01

    Uncertainty in ground heat flux (G) means that evaluation of the other terms in the surface energy balance (e.g., latent and sensible heat fluxes (LE and H)) remains problematic. Algorithms that calculate LE and H require available energy, the difference between net radiation, RNET, and G. There are a wide range of approaches to model G for large-scale applications, with a subsequent wide range of estimates and accuracies. We provide the largest review of these methods to date (N = 6), evaluating modeled G against measured G from 88 FLUXNET sites. The instantaneous midday variability in G is best captured by models forced with net radiation, while models forced by temperature show the least error at both instantaneous and daily time scales. We produce global decadal data sets of G to illustrate regional and seasonal sensitivities, as well as uncertainty. Global model mean midmorning instantaneous G is highest during September, October, and November at 63.42 (±16.84) Wm-2, while over December, January, and February G is lowest at 53.86 (±18.09) Wm-2 but shows greater intermodel uncertainty. Results from this work have the potential to improve evapotranspiration estimates and guide appropriate G model selection and development for various land uses.

  19. Estimation of ground heat flux from soil temperature over a bare soil

    Science.gov (United States)

    An, Kedong; Wang, Wenke; Wang, Zhoufeng; Zhao, Yaqian; Yang, Zeyuan; Chen, Li; Zhang, Zaiyong; Duan, Lei

    2017-08-01

    Ground soil heat flux, G 0, is a difficult-to-measure but important component of the surface energy budget. Over the past years, many methods were proposed to estimate G 0; however, the application of these methods was seldom validated and assessed under different weather conditions. In this study, three popular models (force-restore, conduction-convection, and harmonic) and one widely used method (plate calorimetric), which had well performance in publications, were investigated using field data to estimate daily G 0 on clear, cloudy, and rainy days, while the gradient calorimetric method was regarded as the reference for assessing the accuracy. The results showed that harmonic model was well reproducing the G 0 curve for clear days, but it yielded large errors on cloudy and rainy days. The force-restore model worked well only under rainfall condition, but it was poor to estimate G 0 under rain-free conditions. On the contrary, the conduction-convection model was acceptable to determine G 0 under rain-free conditions, but it generated large errors on rainfall days. More importantly, the plate calorimetric method was the best to estimate G 0 under different weather conditions compared with the three models, but the performance of this method is affected by the placement depth of the heat flux plate. As a result, the heat flux plate was recommended to be buried as close as possible to the surface under clear condition. But under cloudy and rainy conditions, the plate placed at depth of around 0.075 m yielded G 0 well. Overall, the findings of this paper provide guidelines to acquire more accurate estimation of G 0 under different weather conditions, which could improve the surface energy balance in field.

  20. Protective link for superconducting coil

    Science.gov (United States)

    Umans, Stephen D.

    2009-12-08

    A superconducting coil system includes a superconducting coil and a protective link of superconducting material coupled to the superconducting coil. A rotating machine includes first and second coils and a protective link of superconducting material. The second coil is operable to rotate with respect to the first coil. One of the first and second coils is a superconducting coil. The protective link is coupled to the superconducting coil.

  1. Comparison between design and actual energy performance of a HVAC-ground coupled heat pump system in cooling and heating operation

    Energy Technology Data Exchange (ETDEWEB)

    Magraner, T.; Quilis, S. [Energesis Ingenieria S.L., Ciudad Politecnica de la Innovacion, Camino de Vera s/n, 46022 Valencia (Spain); Montero, A. [Instituto de Ingenieria Energetica, Universidad Politecnica de Valencia, Camino de Vera s/n, 46022 Valencia (Spain); Urchueguia, J.F. [Instituto Universitario de Matematica Pura y Aplicada, Universidad Politecnica de Valencia, Camino de Vera s/n, 46022 Valencia (Spain)

    2010-09-15

    This work compares the experimental results obtained for the energy performance study of a ground coupled heat pump system with the design values predicted by means of standard methodology. The system energy performance of a monitored ground coupled heat pump system is calculated using the instantaneous measurements of temperature, flow and power consumption and these values are compared with the numerical predictions. These predictions are performed with the TRNSYS software tool following standard procedures taking the experimental thermal loads as input values. The main result of this work is that simulation results solely based on nominal heat pump capacities and performances overestimate the measured overall energy performance by a percentage between 15% and 20%. A sensitivity analysis of the simulation results to changes in percentage of its input parameters showed that the heat pump nominal coefficient of performance is the parameter that mostly affects the energy performance predictions. This analysis supports the idea that the discrepancies between experimental results and simulation outputs for this ground coupled system are mainly due to heat pump performance degradation for being used at partial load. An estimation of the impact of this effect in energy performance predictions reduces the discrepancies to values around 5%. (author)

  2. Discussion on the Ground Source Heat Pump Pechnology%浅谈地源热泵技术

    Institute of Scientific and Technical Information of China (English)

    齐游洋; 辛立民

    2015-01-01

    The ground source heat pump system is the use of shallow geothermal heating and cooling system can be used in a new type of energy. Efficient use of ground source heat pump technology offers cold energy to the building, in order to meet a variety of building functions, for easy, fast and comfortable en-vironment is the goal of ground source heat pump technology. In order to solve the problem of building energy consumption is too serious, the best way is to research more new and renewable en-ergy, so as to achieve the purpose of building energy efficiency. This paper details the principle of ground source heat pump tech-nology, as well as ground-source heat pump classification and characteristics, and prospects of its development prospects.%地源热泵系统是利用浅层地能进行供热制冷的新型能源所使用的系统。高效利用地源热泵技术提供给建筑的冷热能量,以满足建筑的各种使用功能,实现方便、快捷、舒适的环境,是地源热泵技术实现的目标。为了解决建筑耗能过于严重的问题,最好的办法就是更多地去研究新的可再生能源,从而达到建筑节能的目的。本文主要详细阐述了地源热泵技术的原理,以及地源热泵的分类及其特点,并展望其发展前景。

  3. Spontaneous quenches of a high temperature superconducting pancake coil

    Energy Technology Data Exchange (ETDEWEB)

    Lue, J.W.; Lubell, M.S. [Oak Ridge National Lab., TN (United States); Aized, D.; Campbell, J.M.; Schwall, R.E. [American Superconductor Corp., Westborough, MA (United States)

    1995-09-01

    A double-pancake coil made of Bi-2223/Ag high temperature superconducting (HTS) tape was constructed with an embedded heater and graded conductors to study the stability and quench propagation in HTS coils. The experiments were performed with liquid nitrogen and gaseous helium cooling in temperatures ranging from 5 to 77 K. The coil was very stable, and no ``normal`` zone was sustained or propagated with local pulsed heating. However, spontaneous quenches of the cod were experienced. This was found to be the result of having the coil current higher than that of the lower I{sub c} sections of the coil for a long time. This quench process took minutes to develop--much longer than would be expected in a low temperature superconducting coil. The quench behaved more like a spreading and continuous heating of an increasingly larger partially resistive section of the coil than like a sequential ``normal`` front propagation.

  4. Optimization design and compare of different solar-ground source heat pump system of office building in cold regions

    Science.gov (United States)

    Xie, H.; He, S.; Fu, Y.

    2016-08-01

    This paper presents two different operation modes of Solar-Ground Source Heat Pump System (SGSHP(S)). With the simulation tool TRNSYS, two different SGSHP system models were built to taking simulation. After making analysis and compare of different simulation results, series operation mode was believed to be better than parallel in the target building.

  5. Using distributed temperature sensing to monitor field scale dynamics of ground surface temperature and related substrate heat flux

    NARCIS (Netherlands)

    Bense, V.F.; Read, T.; Verhoef, A.

    2016-01-01

    We present one of the first studies of the use of distributed temperature sensing (DTS) along fibre-optic cables to purposely monitor spatial and temporal variations in ground surface temperature (GST) and soil temperature, and provide an estimate of the heat flux at the base of the canopy layer

  6. On the Technology of Ground Source Heat Pump%浅谈地源热泵技术

    Institute of Scientific and Technical Information of China (English)

    屈东升

    2012-01-01

    The concept of ground source heat pump technology is described. The working principle and classification, the composition of ground source heat pump is introduced. The characteristics and actual application of ground source heat pump is analyzed. It is pointed out that the ground source heat pump which is a renewable energy has broad developing and applying prospects in energy saving and exhaustion-reducing, environmental protection, sustainable development in our country.%阐述地源热泵技术的概念。介绍地源热泵系统的组成部分、工作原理和分类,分析地源热泵系统的特点和实际应用情况。提出地源热泵这种可再生能源在我国节能降耗、生态环保、可持续发展中具有广阔的发展和应用前景。

  7. Numerical simulation of heat transfer enhancement by strip-coil-baffles in tube-bundle for a tube-shell heat exchanger%螺旋折流片强化管壳式换热器内管束传热数值模拟

    Institute of Scientific and Technical Information of China (English)

    陈亚平; 梅娜; 施明恒

    2007-01-01

    介绍了一种用于强化管壳式换热器壳侧传热和支撑管束的螺旋折流片新型结构,该结构是对换热器管子相间地套上螺旋折流片以产生旋涡流动.研究模型是在正方形布置的4个管子中的2个对角管子套上螺旋折流片后形成的通道,利用FLUENT软件对该上述四管通道模型的流场和温度分布情况进行了数值模拟;分析了四管通道模型中螺旋折流片对强化传热和流动阻力随雷诺数的变化关系的影响.算例结果显示该新型结构可比相同尺寸的光管通道中的情形传热系数提高约40%~55%,同时也将伴随较高的流动阻力.可以相信螺旋折流片式换热器将会在许多工业领域有良好的应用前景.%A novel strip-coil-baffle structure used to enhance heat transfer and support the tube bundle for a tube-shell heat exchanger is proposed.The new structure can sleeve the tubes in bundle alternatively to create a vortex flow in a heat exchanger.The numerical simulation on the flow and heat transfer characteristics for this new structure heat exchanger is conducted.The computational domain consists of two strip-coil sleeved tubes and two bare tubes oppositely placed at each corner of a square.The velocity and temperature fields in such strip-coil-baffled channel are simulated using FLUENT software.The effects of the strip-coil-baffles on heat transfer enhancement and flow resistance in relation to the Reynolds number are analyzed.The results show that this new structure bundle can enhance the heat transfer coefficient up to a range of 40% to 55% in comparison with a bare tube bundle;meanwhile,higher flow resistance is also accompanied.It is believe that the strip-coil-baffled heat exchanger should have promising applications in many industry fields.

  8. Guide to the Revised Ground-Water Flow and Heat Transport Simulator: HYDROTHERM - Version 3

    Science.gov (United States)

    Kipp, Kenneth L.; Hsieh, Paul A.; Charlton, Scott R.

    2008-01-01

    The HYDROTHERM computer program simulates multi-phase ground-water flow and associated thermal energy transport in three dimensions. It can handle high fluid pressures, up to 1 ? 109 pascals (104 atmospheres), and high temperatures, up to 1,200 degrees Celsius. This report documents the release of Version 3, which includes various additions, modifications, and corrections that have been made to the original simulator. Primary changes to the simulator include: (1) the ability to simulate unconfined ground-water flow, (2) a precipitation-recharge boundary condition, (3) a seepage-surface boundary condition at the land surface, (4) the removal of the limitation that a specified-pressure boundary also have a specified temperature, (5) a new iterative solver for the linear equations based on a generalized minimum-residual method, (6) the ability to use time- or depth-dependent functions for permeability, (7) the conversion of the program code to Fortran 90 to employ dynamic allocation of arrays, and (8) the incorporation of a graphical user interface (GUI) for input and output. The graphical user interface has been developed for defining a simulation, running the HYDROTHERM simulator interactively, and displaying the results. The combination of the graphical user interface and the HYDROTHERM simulator forms the HYDROTHERM INTERACTIVE (HTI) program. HTI can be used for two-dimensional simulations only. New features in Version 3 of the HYDROTHERM simulator have been verified using four test problems. Three problems come from the published literature and one problem was simulated by another partially saturated flow and thermal transport simulator. The test problems include: transient partially saturated vertical infiltration, transient one-dimensional horizontal infiltration, two-dimensional steady-state drainage with a seepage surface, and two-dimensional drainage with coupled heat transport. An example application to a hypothetical stratovolcano system with unconfined

  9. Optimum bleeding rate of open loop ground source heat pump systems determined by hydrogeological modeling in Korea

    Science.gov (United States)

    Jeon, W. H.; Kim, N.; Lee, J. Y.

    2014-12-01

    This study aims to evaluate the influence of open loop ground source heat pump systems operation on hydrological conditions of aquifer. Test bed is located in Chuncheon, Korea. The step drawdown test was conducted in five stages for 300 minutes. The variation of groundwater levels by open loop ground source heat pump systems operation was estimated using Visual MODFLOW. Transmissivity ranged from 2.02×10-4 to 9.36×10-4, and storage coefficient ranged from 0.00067 to 0.021. The amount of optimum bleeding was calculated to be 240 m3/day. When bleeding will be 50, 90, 240 and 450 m3/day for 5 years, groundwater levels may decrease 1.84, 3.31, 8.89 and 17.0 m, respectively. If the amount of bleeding is 50 m3/day, the influence of bleeding will not reach the boundary regions of the Soyang River after 5 years. Regarding the open loop ground source heat pump system installed at the test bed, the amount of optimum bleeding in accordance with the stand are proposed by the government is 90 m3/day, which is 20% of the 450 m3/day circulation quantity of the system. However, if continuous bleeding of more than 90 m3/day occurs, then the radius of influence is expected to reach the boundary regions of the Soyang River after 5 years. These results indicate that amount of optimum bleeding differ in each open loop ground soured heat pump system. Therefore, the debate for the amount of optimum bleeding in open loop ground source heat pump systems is demanded. This work is supported by the Energy Efficiency and Resources of the Korea Institute of Energy Technology Evaluation and Planning (KETEP) grant funded by the Korea government Ministry of Knowledge Economy (No.20123040110010).

  10. Dynamics Near the Ground State for the Energy Critical Nonlinear Heat Equation in Large Dimensions

    Science.gov (United States)

    Collot, Charles; Merle, Frank; Raphaël, Pierre

    2016-11-01

    We consider the energy critical semilinear heat equation partial_tu = Δ u + |u|^{4/d-2}u, quad x in R^d and give a complete classification of the flow near the ground state solitary wave Q(x) = 1/(1+{|x|^2/{d(d-2)})^{d-2/2}} in dimension {d ≥ 7} , in the energy critical topology and without radial symmetry assumption. Given an initial data {Q + ɛ_0} with {|nabla ɛ_0|_{L^2} ≪ 1} , the solution either blows up in the ODE type I regime, or dissipates, and these two open sets are separated by a codimension one set of solutions asymptotically attracted by the solitary wave. In particular, non self similar type II blow up is ruled out in dimension {d ≥ 7} near the solitary wave even though it is known to occur in smaller dimensions (Schweyer, J Funct Anal 263(12):3922-3983, 2012). Our proof is based on sole energy estimates deeply connected to Martel et al. (Acta Math 212(1):59-140, 2014) and draws a route map for the classification of the flow near the solitary wave in the energy critical setting. A by-product of our method is the classification of minimal elements around Q belonging to the unstable manifold.

  11. Evaluation of federal and state subsidies for ground-source heat pumps

    Energy Technology Data Exchange (ETDEWEB)

    Blumsack, S.; Kleit, A. [Department of Energy and Mineral Engineering, The Pennsylvania State University, 213 Hosler Building University Park, PA (United States); Smith, S.W. [Westcott Consulting, 110 Hosler Building, Boulder, CO (United States)

    2012-08-15

    Energy efficiency can be a powerful way to lower energy bills, as well as the external (social) costs associated with energy consumption. Previous experience and research, however, has demonstrated that consumers are often unwilling to make investments in energy efficiency, even when such investments have relatively short payback periods. Because energy efficiency can contribute to correcting negative externalities associated with energy use, subsidies and other programs have been proposed as a way to increase efficiency investments. Thus, under the right circumstances, such subsidies can improve economic efficiency. In this paper, we analyze the economics of energy-efficient space conditioning using data from an actual household in rural Pennsylvania to evaluate ground-source heat pumps (GHP). GHP technology has been advocated as a potentially appealing energy efficiency measure for rural communities. We find that with current subsidies GHP is economically viable for a wide range of electricity prices. We also find, however, that current subsidies are actually greater than those that can be economically justified. Using the efficient level of subsidies reduces, but does not eliminate, the economic case for GHP technology. We also evaluate the economics of efficiency subsidies using an ambitious program in Pennsylvania as a case study. The program, known as the Alternative Energy Investment Act (AEIA), provides subsidies for GHP among other technologies. We find that the substantial federal subsidies for GHP undercut the economic efficiency arguments for the AEIA with respect to GHP.

  12. Dual coil ignition system

    Energy Technology Data Exchange (ETDEWEB)

    Huberts, Garlan J.; Qu, Qiuping; Czekala, Michael Damian

    2017-03-28

    A dual coil ignition system is provided. The dual coil ignition system includes a first inductive ignition coil including a first primary winding and a first secondary winding, and a second inductive ignition coil including a second primary winding and a second secondary winding, the second secondary winding connected in series to the first secondary winding. The dual coil ignition system further includes a diode network including a first diode and a second diode connected between the first secondary winding and the second secondary winding.

  13. Recovery Act - Geothermal Technologies Program: Ground Source Heat Pumps Final Scientific/Technical Report

    Energy Technology Data Exchange (ETDEWEB)

    Nick Rosenberry, Harris Companies

    2012-05-04

    A large centralized geothermal heat pump system was installed to provide ice making, space cooling, space heating, process water heating, and domestic hot water heating for an ice arena in Eagan Minnesota. This paper provides information related to the design and construction of the project. Additionally, operating conditions for 12 months after start-up are provided.

  14. Simulation and optimisation of a ground source heat pump with different ground heat exchanger configurations for a single-family residential house

    DEFF Research Database (Denmark)

    Pavlov, Georgi Krasimiroy; Olesen, Bjarne W.

    2012-01-01

    -temperature heating and high-temperature cooling system. The present work evaluates the performance in relation to thermal comfort and energy consumption of a GSHP with different GHE concepts. The different configurations are analyzed being part of the energy supply system of a low-energy residential house...

  15. Heat load tests of superconducting magnets vibrated electromagnetically for the Maglev train

    Science.gov (United States)

    Ohmori, J.; Nakao, H.; Yamashita, T.; Sanada, Y.; Shudou, M.; Kawai, M.; Fujita, M.; Terai, M.; Miura, A.

    Superconducting magnets on Maglev trains vibrate due to harmonic ripples of electromagnetic flux generated by ground coils. Heat load caused by vibration in the magnet amounted to several tens of watts in the electromagnetic vibration test. This was mainly because a.c. loss was induced in the helium vessel housing the superconducting coil, due to relative vibration between the aluminium thermal shield and the coil. The heat load caused by vibration should be strictly restricted to less than 4W due to limited cryogenic refrigeration capacity. The heat load was tested using electromagnetic flux ripples for a superconducting magnet model of one coil which corresponds to 1/4 of an actual magnet. The flux ripples simulated the 6th harmonic of the actual ground levitation coil. Some ideas to reduce the heat load were tried for the magnet model, such as applying high resistance thermal radiation shielding, increasing rigidity of the vacuum vessel, and using high purity copper plating on the helium vessel. These ideas proved effective, and the maximum heat load due to vibration was held to less than 4 W per magnet for the one coil magnet model.

  16. Avaliacão de programas de aquecimento para espectrometria de absorção atômica com atomizacão eletrotérmica em filamento de tungstênio Evaluation of heating programs for electrothermal atomic absorption spectrometry using a tungsten coil

    Directory of Open Access Journals (Sweden)

    Pedro V. Oliveira

    2000-10-01

    Full Text Available A tungsten coil atomizer was used to investigate the effect of heating programs with constant or variable drying temperatures on the atomization of Al, Cd, Cr and Pb. The variation of the surface temperature in the tungsten coil furnace can occur during each heating step due to the design of the power supply, that may apply constant voltages during a programmed time. For volatile elements (Cd, losses in sensitivity were observed when the program with a variable temperature was used. On the other hand, these effects are negligible for less volatile elements (Al and Cr and any tested program, in different acidic media, could be used without appreciable changes in sensitivities. The results allow the establishment of proper heating programs for elements with different thermochemical behavior in the tungsten coil atomizer.

  17. Energy performance of a ventilation system for a block of apartments with a ground source heat pump as generation system

    Science.gov (United States)

    Lucchi, M.; Lorenzini, M.; Valdiserri, P.

    2017-01-01

    This work presents a numerical simulation of the annual performance of two different systems: a traditional one composed by a gas boiler-chiller pair and one consisting of a ground source heat pump (GSHP) both coupled to two thermal storage tanks. The systems serve a bloc of flats located in northern Italy and are assessed over a typical weather year, covering both the heating and cooling seasons. The air handling unit (AHU) coupled with the GSHP exhibits excellent characteristics in terms of temperature control, and has high performance parameters (EER and COP), which make conduction costs about 30% lower than those estimated for the traditional plant.

  18. Solar Assisted Ground Source Heat Pump Performance in Nearly Zero Energy Building in Baltic Countries

    National Research Council Canada - National Science Library

    Karolis Januševičius; Giedrė Streckienė

    2013-01-01

    .... Heat pump systems are a widespread solution to reduce energy use. A combination of heat pump and solar thermal collectors helps to meet standard requirements and increases the share of renewable energy use in total energy balance of country...

  19. Ground-Source Heat Pumps. Overview of Market Status, Barriers to Adoption, and Options for Overcoming Barriers

    Energy Technology Data Exchange (ETDEWEB)

    Goetzler, William [Navigant Consulting, Inc., Chicago, IL (United States); Zogg, Robert [Navigant Consulting, Inc., Chicago, IL (United States); Lisle, Heather [Navigant Consulting, Inc., Chicago, IL (United States); Burgos, Javier [Navigant Consulting, Inc., Chicago, IL (United States)

    2009-02-03

    February 2009 final report submitted to DOE by Navigant Consulting, Inc. This report summarizes the status of ground-source heat pump (GSHP) technology and market penetration globally, estimates the energy saving potential of GSHPs in the U.S., identifies key market barriers that are inhibiting wider market adoption of GSHPs, and recommends initiatives that can be implemented or facilitated by the DOE to accelerate market adoption.

  20. An In-Depth Look at Ground Source Heat Pumps and Other Electric Loads in Two GreenMax Homes

    Energy Technology Data Exchange (ETDEWEB)

    Puttagunta, Srikanth [Consortium for Advanced Residential Buildings (CARB), Norwalk, CT (United States); Shapiro, Carl [Consortium for Advanced Residential Buildings (CARB), Norwalk, CT (United States)

    2012-04-01

    Building America research team Consortium for Advanced Residential Buildings (CARB) partnered with WPPI Energy to answer key research questions on in-field performance of ground-source heat pumps and lighting, appliance, and miscellaneous loads (LAMELs) through extensive field monitoring at two WPPI GreenMax demonstration homes in Wisconsin. These two test home evaluations provided valuable data on the true in-field performance of various building mechanical systems and LAMELs.

  1. Performance Evaluation of Radiator and Radiant Floor Heating Systems for an Office Room Connected to a Ground-Coupled Heat Pump

    Directory of Open Access Journals (Sweden)

    Ioan Sarbu

    2016-03-01

    Full Text Available A ground-coupled heat pump (GCHP system used to provide the space heating for an office room is a renewable, high performance technology. This paper discusses vapour compression-based HP systems, briefly describing the thermodynamic cycle calculations, as well as the coefficient of performance (COP and CO2 emissions of a HP with an electro-compressor and compares different heating systems in terms of energy consumption, thermal comfort and environmental impact. It is focused on an experimental study performed to test the energy efficiency of the radiator or radiant floor heating system for an office room connected to a GCHP. The main performance parameters (COP and CO2 emissions are obtained for one month of operation of the GCHP system, and a comparative analysis of these parameters is presented. Additionally, two numerical simulation models of useful thermal energy and the system COP in heating mode are developed using the Transient Systems Simulation (TRNSYS software. Finally, the simulations obtained from TRNSYS software are analysed and compared to the experimental data, showing good agreement and thus validating the simulation models.

  2. Experimental research on heat transfer performances of salty bath spiral coil waste heat recovery equipment in coke oven ascending pipe%盐浴螺旋盘管式焦炉上升管余热回收装置传热性能试验

    Institute of Scientific and Technical Information of China (English)

    杨哲君; 张素军; 李菊香

    2015-01-01

    对盐浴螺旋盘管式结构的焦炉上升管高温荒煤气余热回收装置进行了以烟气代替荒煤气的传热性能模拟试验,得到了上升管余热回收装置螺旋盘管环形套筒的外壁温度分布、上升管内烟气侧的传热系数、环形套筒内螺旋盘管外盐浴的自然对流传热系数等试验研究结果.结果表明,装置螺旋盘管环形套筒的外壁温度分布并非均匀,随上升管内烟气温度的升高而波动增大;烟气侧对流传热系数在Re数高于2900后随Re数的增大而明显上升;螺旋盘管外盐浴的自然对流传热系数随熔盐温度的升高几乎不变.根据试验结果拟合出环形套筒内螺旋盘管外盐浴的自然对流传热关联式,为实际的工程应用提供参考.%This paper tested the heat transfer performances of a salty bath spiral coil high temperature coke-oven gas waste heat recovery equipment in coke oven ascending pipe. Flue gas was instead of coke-oven gas as the heat transfer media. The experiment obtained temperature distribution of spiral coil sleeve on the outer wall of the waste heat recovery equipment,the heat transfer coefficients of flue gas in ascending pipe,the outer natural convection heat transfer coefficients of salty bath spiral coil in annular sleeve and other experiment results. The test results showed that the temperature distribution of spiral coil sleeve on the outer wall was not uniform,and fluctuated more as the flue gas temperature increased in the ascending pipe;the convection heat transfer coefficient of flue gas increased evidently with the increase ofRe number especially afterRe number was greater than 2900;the outer natural convection heat transfer coefficient of the salty bath spiral coil was almost a constant value with the increase of molten salt temperature. Based on the test results,this paper presented the outer natural convection heat transfer correlation of the salty bath spiral coil in annular sleeve

  3. ENERGY AND ENVIRONMENTAL ANALYSIS OF AN OPEN-LOOP GROUND-WATER HEAT PUMP SYSTEM IN AN URBAN AREA

    Directory of Open Access Journals (Sweden)

    Giorgia Baccino

    2010-01-01

    Full Text Available In this paper a multidisciplinary methodology for analyzing the opportunities for exploitation of open-loop groundwater heat pump is proposed. The approach starts from a model for calculation of a time profile of thermal requirements (heat and domestic hot water. This curve is then coupled with a model of the control system in order to determine the heat pump operation, which includes its energy performances (primary energy consumption as well as profiles of water discharge to the aquifer in terms of mass flow rate and temperature. Then the thermo-fluid dynamics of the aquifer is performed in order to determine the system impact on the environment as on possible other systems. The application to a case study in the Piedmont region, in Italy, is proposed. Energy analysis of the system shows that ground-water heat pumps constitute an interesting option in areas with small housing density, where there is not district heating. In comparison with typical heating/cooling systems, environmental benefits are related with reduction in global emissions. These benefits may be significantly enhanced using renewables as the primary energy source to produce electricity. The analysis also shows that possible issues related with the extension of the subsurface thermal plume may arise in the case of massive utilization of this technology.

  4. Air/ground heat exchanger (GHE): Modelling, design, performance; Luft-/Erdwaermetauscher EWT: Modellierung, Auslegung und Betriebserfahrungen

    Energy Technology Data Exchange (ETDEWEB)

    Gerber, A. [Fraunhofer-Inst. fuer Solare Energiesysteme, Freiburg (Germany); Pfafferott, J. [Energieversorgung Spree-Schwarze Elster AG (ESSAG), Cottbus (Germany); Dibowski, G. [Deutsches Zentrum fuer Luft- und Raumfahrt e.V. (DLR), Koeln (Germany). Abt. Sonnenofen

    1998-02-01

    Air/Ground Heat Exchanger (GHE) utilize soil for seasonal heat storage and are used for air preheating or -cooling. Design and layout require suitable tools which adequately describe the complex heat temperature mechanisms in soils. Since heat densities in soil and heat exchange coefficients between air and GHE are both low, a detailed characterization of the soil and a precise modeling of the heat exchange processes within the GHE are needed. Tools for the design and yield prediction of GHE are presented by way of examples. Results are compared with measured data and both opportunities and limitations of GHEs are discussed using calculated and actual data. (orig.) [Deutsch] Luft-/Erdwaermetauscher EWT nutzen das Erdreich als saisonalen Energiespeicher, sie werden beispielsweise zur Zuluft-Vorerwaermung oder -kuehlung eingesetzt. Die Planung und Auslegung von Luft-/Erdwaermetauschern erfordert geeignete Hilfsmittel, um das komplizierte Temperaturfeld im Erdreich mit ausreichender Genauigkeit abbilden zu koennen. Da die Waermestromdichten im Erdreich und der Waermeuebergang zwischen der Luft im Luft-/Erdwaermetauscher und dem umgebenden Erdreich gering sind, ist sowohl eine detaillierte Abbildung des Erdreichs als auch die Modellierung des Waermeuebergangs im Luft-/Erdwaermetauscher erforderlich. Verfahren zur Auslegung und Ertragsvorhersage von Luft-/Erdwaermetauschern werden vorgestellt und deren Anwendung demonstriert. Die Ergebnisse werden mit Betriebserfahrungen von realisierten Luft-/Erdwrmetauschern verglichen. Moeglichkeiten und Grenzen von Luft-/Erdwaermetauschern werden anhand von Praxis und Simulationsrechnungen diskutiert. (orig.)

  5. Coil system for plasmoid thruster

    Science.gov (United States)

    Eskridge, Richard H. (Inventor); Lee, Michael H. (Inventor); Martin, Adam K. (Inventor); Fimognari, Peter J. (Inventor)

    2010-01-01

    A coil system for a plasmoid thruster includes a bias coil, a drive coil and field coils. The bias and drive coils are interleaved with one another as they are helically wound about a conical region. A first field coil defines a first passage at one end of the conical region, and is connected in series with the bias coil. A second field coil defines a second passage at an opposing end of the conical region, and is connected in series with the bias coil.

  6. First assembly phase for the ATLAS toroid coils

    CERN Multimedia

    Maximilien Brice

    2003-01-01

    The ATLAS barrel toroid system consists of eight coils, each of axial length 25.3 m, assembled radially and symmetrically around the beam axis. The coils are of a flat racetrack type with two double-pancake windings made of 20.5 kA aluminium-stabilized niobium-titanium superconductor. In the first phase of assembly, the two 'pancakes' are packed into their vacuum vessel. This is done using bladders filled with resin and glass microbeads under pressure. The resin is heated and, once cooled, holds the pancakes in place. The operation has to be performed on both sides of the coil, which necessitated a special technique to turn the coils over and then transport them to the heating table. Photos 01, 02, 03: Transporting the coil to the heating table using a special lifting gantry manufactured at JINR-Dubna, Russia in preparation for the 'bladderisation' operation.

  7. An early attempt at an integrated home energy system including solar thermal, ground source heat pump, radiant floor heating, reflective and dynamic insulation and ground-tempered makeup air

    Energy Technology Data Exchange (ETDEWEB)

    White, T.

    2005-07-01

    This paper described an attempt to design and build a comfortable and energy efficient home that integrates solar thermal panels with active and passive features. The exterior walls of the 1700 square foot house were interlocking concrete blocks with radiant floor heating pipes fastened to the outside, which was later covered with rigid insulation and stucco. The active heating system included 4 solar panels and a ground source heat pump with supply lines buried horizontally 5 feet below the surface of the back yard on the south side of the building. The solar panels were used for different purposes in different seasons. The system was monitored for the first winter only. For 4 hours a day in January, 10 per cent more solar energy was measured on the vertical collectors than is available from direct solar insolation at summer solstice. With an outside temperature of -33 degrees C, the solar collectors were capable of maintaining an almost constant core wall temperature of 12 degrees C. The total electricity bill for this all-electric house averaged $60 month during for an entire year, with a single occupant. Despite these results, funding to optimize the control system was not granted. The house was sold at a loss and the heat pump was eventually replaced by a natural gas boiler, which reduced the energy efficiency of the house, but which satisfied the bank who wanted a conventional heating system before approving a mortgage. 2 figs.

  8. 地源热泵的地埋管群换热特性研究%Heat transfer characteristics of underground heat exchanger group in ground-source heat pump systems

    Institute of Scientific and Technical Information of China (English)

    於仲义; 陈焰华; 雷建平

    2012-01-01

    结合武汉某实际工程的地埋管群阵列布置情况和地源热泵系统的运行情况,对典型区域的地埋管群运行5年中的埋管换热特性进行了动态数值模拟和分析.提出了温度偏离度和换热保证度的概念,并研究了二者在地源热泵长期运行过程中的变化规律.建议尽量减小冷热负荷不平衡率,以保证地源热泵系统稳定可靠的运行.%Based on the arrangement of the underground heat exchanger group and the operation conditions of the ground-source heat pump system of an actual project in Wuhan, performs a dynamic numerical simulation and analysis of the heat transfer characteristics of the underground heat exchanger group during a five-year operation period in typical zones. Presents the concepts of temperature deviation degree and heat transfer assurance factor, and studies their variation in a long term operation process of ground-source heat pump systems. Proposes that the imbalance rate between cooling and heating load should be reduced as much as possible to ensure the stability and reliability of ground-source heat pump system operation.

  9. Mitigation potential of horizontal ground coupled heat pumps for current and future climatic conditions: UK environmental modelling and monitoring studies

    Science.gov (United States)

    García González, Raquel; Verhoef, Anne; Vidale, Pier Luigi; Gan, Guohui; Wu, Yupeng; Hughes, Andrew; Mansour, Majdi; Blyth, Eleanor; Finch, Jon; Main, Bruce

    2010-05-01

    An increased uptake of alternative low or non-CO2 emitting energy sources is one of the key priorities for policy makers to mitigate the effects of environmental change. Relatively little work has been undertaken on the mitigation potential of Ground Coupled Heat Pumps (GCHPs) despite the fact that a GCHP could significantly reduce CO2 emissions from heating systems. It is predicted that under climate change the most probable scenario is for UK temperatures to increase and for winter rainfall to become more abundant; the latter is likely to cause a general rise in groundwater levels. Summer rainfall may reduce considerably, while vegetation type and density may change. Furthermore, recent studies underline the likelihood of an increase in the number of heat waves. Under such a scenario, GCHPs will increasingly be used for cooling as well as heating. These factors will affect long-term performance of horizontal GCHP systems and hence their economic viability and mitigation potential during their life span ( 50 years). The seasonal temperature differences encountered in soil are harnessed by GCHPs to provide heating in the winter and cooling in the summer. The performance of a GCHP system will depend on technical factors (heat exchanger (HE) type, length, depth, and spacing of pipes), but also it will be determined to a large extent by interactions between the below-ground parts of the system and the environment (atmospheric conditions, vegetation and soil characteristics). Depending on the balance between extraction and rejection of heat from and to the ground, the soil temperature in the neighbourhood of the HE may fall or rise. The GROMIT project (GROund coupled heat pumps MITigation potential), funded by the Natural Environment Research Council (UK), is a multi-disciplinary research project, in collaboration with EarthEnergy Ltd., which aims to quantify the CO2 mitigation potential of horizontal GCHPs. It considers changing environmental conditions and combines

  10. Research on influence of coil panels of household induction cookers on heat efficiency testing%家用电磁灶线圈盘对热效率测试影响的研究

    Institute of Scientific and Technical Information of China (English)

    陈剑; 张少君; 徐善伟

    2012-01-01

    When operating the induction cookers, the tester watched the standard span and several temperature spots of the water therein, and on this basis made the comparison research about the influence of the electromagnetic induction of various induction cooker coil panels on the standard span and the water heating process. To calculate the heat efficiency value of household electromagnetic stove applying the testing method stipulated by GB 21456-2008 The minimum allowable values of the energy efficiency and energy efficiency grades for household induction cookers, the data got thereby shown that, irregular distribution of coil panes will lead to uneven intensity of electromagnetic induction, and so produces inconsistent temperature fields in the standard span. Specifically speaking, the stronger the electromagnetic induction is, the higher the partial temperature thereby will be, and vice versa.%在电磁灶工作状态下,对标准锅以及水溶液的若干温度点分别监测,研究电磁灶线圈盘产生的电磁感应对标准锅以及容器中水的整个加热过程的影响,并运用GB 21456-2008《家用电磁灶能效限定值及能源效率等级》的测试方法计算家用电磁灶热效率值.试验结果表明:线圈盘的分布不均会导致电磁感应强度不均,从而会在标准锅锅体产生不同的温度场.感应磁场越强,局部温度就越高,感应磁场越弱,局部温度就越低.

  11. Optimization of ground source heat pumps related to soil and groundwater conditions as well as grouting material; Optimierung von Waermepumpen in Bezug auf Boden- und Grundwasserverhaeltnisse sowie Verpressmaterial

    Energy Technology Data Exchange (ETDEWEB)

    Katzenbach, R.; Clauss, F.; Waberseck, T. [Technische Univ. Darmstadt (Germany). Inst. und Versuchsanstalt fuer Geotechnik; Sass, J. [Technische Univ. Darmstadt (Germany). Inst. fuer Angewandte Geowissenschaften, Fachgebiet Ingenieurgeologie

    2006-07-01

    The capacity and the performance of ground source heat pumps and seasonal thermal storage systems with borehole heat exchangers depend on the conditions of the encountered subsoil and the groundwater and furthermore on the thermal properties of the grouting material used for conclusive backfilling of the annular space after installing the heat exchanger pipes in the borehole. Intensive investigations are carried out at the Technische Universitaet Darmstadt with the aim of an economical optimisation of the dimensioning of ground source heat pumps and seasonal thermal storage systems. (orig.)

  12. Liquid rope coiling

    NARCIS (Netherlands)

    N.M. Ribe; M. Habibi; D. Bonn

    2012-01-01

    A thin stream or rope of viscous fluid falling from a sufficient height onto a surface forms a steadily rotating helical coil. Tabletop laboratory experiments in combination with a numerical model for slender liquid ropes reveal that finite-amplitude coiling can occur in four distinct regimes (visco

  13. Optimal Bitter Coil Solenoid

    CERN Document Server

    Kobelev, V

    2016-01-01

    Bitter coil is an electromagnet used for the generation of exceptionally strong magnetic fields. The upper bound of magnet flux density is restricted by several factors. One principal restriction is the high stresses due to Lorentz forces in the coil. The Lorentz forces generate the distributed body force, which acts as the pressure of magnetic field. The common radial thickness profile of the Bitter coil is constant. In this paper the possibility of optimization by means of non-constant radial thickness profile of the Bitter coil is studied. The close form expression for optimal thickness profile is obtained. Both designs are compared and the considerable improvement of magnetic flux density is demonstrated. Moreover, the optimal design improves the shape of cooling channels. Namely, the highest cross-section of cooling channel is at the most thermally loaded inner surface of the coil.

  14. Heat flow and ground water flow in the Great Plains of the United States

    Science.gov (United States)

    Gosnold, William D.

    1985-12-01

    Regional groundwater flow in deep aquifers adds advective components to the surface heat flow over extensive areas within the Great Plains province. The regional groundwater flow is driven by topographically controlled piezometric surfaces for confined aquifers that recharge either at high elevations on the western edge of the province or from subcrop contacts. The aquifers discharge at lower elevations to the east. The assymetrical geometry for the Denver and Kennedy Basins is such that the surface areas of aquifer recharge are small compared to the areas of discharge. Consequently, positive advective heat flow occurs over most of the province. The advective component of heat flow in the Denver Basin is on the order of 15 mW m -2 along a zone about 50 km wide that parallels the structure contours of the Dakota aquifer on the eastern margin of the Basin. The advective component of heat flow in the Kennedy Basin is on the order of 20 mW m -2 and occurs over an extensive area that coincides with the discharge areas of the Madison (Mississippian) and Dakota (Cretaceous) aquifers. Groundwater flow in Paleozoic and Mesozoic aquifers in the Williston Basin causes thermal anomalies that are seen in geothermal gradient data and in oil well temperature data. The pervasive nature of advective heat flow components in the Great Plains tends to mask the heat flow structure of the crust, and only heat flow data from holes drilled into the crystalline basement can be used for tectonic heat flow studies.

  15. Recovery Act: Tennessee Energy Efficient Schools Initiative Ground Source Heat Pump Program

    Energy Technology Data Exchange (ETDEWEB)

    Townsend, Terry [Townsend Engineering, Inc., Davenport, IA (United States); Slusher, Scott [Townsend Engineering, Inc., Davenport, IA (United States)

    2017-04-24

    The Tennessee Energy Efficient Schools Initiative (EESI) Hybrid-Water Source Heat Pump (HY-GSHP) Program sought to provide installation costs and operation costs for different Hybrid water source heat pump systems’ configurations so that other State of Tennessee School Districts will have a resource for comparison purposes if considering a geothermal system.

  16. Solar Assisted Ground Source Heat Pump Performance in Nearly Zero Energy Building in Baltic Countries

    Science.gov (United States)

    Januševičius, Karolis; Streckienė, Giedrė

    2013-12-01

    In near zero energy buildings (NZEB) built in Baltic countries, heat production systems meet the challenge of large share domestic hot water demand and high required heating capacity. Due to passive solar design, cooling demand in residential buildings also needs an assessment and solution. Heat pump systems are a widespread solution to reduce energy use. A combination of heat pump and solar thermal collectors helps to meet standard requirements and increases the share of renewable energy use in total energy balance of country. The presented paper describes a simulation study of solar assisted heat pump systems carried out in TRNSYS. The purpose of this simulation was to investigate how the performance of a solar assisted heat pump combination varies in near zero energy building. Results of three systems were compared to autonomous (independent) systems simulated performance. Different solar assisted heat pump design solutions with serial and parallel solar thermal collector connections to the heat pump loop were modelled and a passive cooling possibility was assessed. Simulations were performed for three Baltic countries: Lithuania, Latvia and Estonia.

  17. Permafrost thawing in organic Arctic soils accelerated by ground heat production

    DEFF Research Database (Denmark)

    Hollesen, Jørgen; Matthiesen, Henning; Møller, Anders Bjørn

    2015-01-01

    Decomposition of organic carbon from thawing permafrost soils and the resulting release of carbon to the atmosphere are considered to represent a potentially critical global-scale feedback on climate change1, 2. The accompanying heat production from microbial metabolism of organic material has been...... recognized as a potential positive-feedback mechanism that would enhance permafrost thawing and the release of carbon3, 4. This internal heat production is poorly understood, however, and the strength of this effect remains unclear3. Here, we have quantified the variability of heat production in contrasting...... organic permafrost soils across Greenland and tested the hypothesis that these soils produce enough heat to reach a tipping point after which internal heat production can accelerate the decomposition processes. Results show that the impact of climate changes on natural organic soils can be accelerated...

  18. Permafrost thawing in organic Arctic soils accelerated by ground heat production

    DEFF Research Database (Denmark)

    Hollesen, Jørgen; Matthiesen, Henning; Moller, Anders Bjorn;

    2015-01-01

    Decomposition of organic carbon from thawing permafrost soils and the resulting release of carbon to the atmosphere are considered to represent a potentially critical global-scale feedback on climate change1, 2. The accompanying heat production from microbial metabolism of organic material has been...... recognized as a potential positive-feedback mechanism that would enhance permafrost thawing and the release of carbon3, 4. This internal heat production is poorly understood, however, and the strength of this effect remains unclear3. Here, we have quantified the variability of heat production in contrasting...... organic permafrost soils across Greenland and tested the hypothesis that these soils produce enough heat to reach a tipping point after which internal heat production can accelerate the decomposition processes. Results show that the impact of climate changes on natural organic soils can be accelerated...

  19. Study on the Optimizing Operation of Exhaust Air Heat Recovery and Solar Energy Combined Thermal Compensation System for Ground-Coupled Heat Pump

    Directory of Open Access Journals (Sweden)

    Kuan Wang

    2017-01-01

    Full Text Available This study proposed an exhaust air heat recovery and solar energy combined thermal compensation system (ESTC for ground-coupled heat pumps. Based on the prediction of the next day’s exhaust air temperature and solar irradiance, an optimized thermal compensation (OTC method was developed in this study as well, in which the exhaust air heat recovery compensator and solar energy compensator in the ESTC system run at high efficiency throughout various times of day. Moreover, a modified solar term similar days group (STSDG method was proposed to improve the accuracy of solar irradiance prediction in hazy weather. This modified STSDG method was based on air quality forecast and AQI (air quality index correction factors. Through analyzing the operating parameters and the simulation results of a case study, the ESTC system proved to have good performance and high efficiency in eliminating the heat imbalance by using the OTC method. The thermal compensation quantity per unit energy consumption (TEC of ESTC under the proposed method was 1.25 times as high as that under the traditional operation method. The modified STSDG method also exhibited high accuracy. For the accumulated solar irradiance of the four highest daily radiation hours, the monthly mean absolute percentage error (MAPE between the predicted values and the measured values was 6.35%.

  20. Heat exchanger

    Energy Technology Data Exchange (ETDEWEB)

    Craig, L.B.; Farma, A.J.

    1987-01-06

    This invention concerns a heat exchanger as used in a space heater, of the type in which hot exhaust gases transfer heat to water or the like flowing through a helical heat exchange coil. A significant improvement to the efficiency of the heat exchange occurring between the air and water is achieved by using a conduit for the water having external helical fluting such that the hot gases circulate along two paths, rather than only one. A preferred embodiment of such a heat exchanger includes a porous combustion element for producing radiant heat from a combustible gas, surrounded by a helical coil for effectively transferring the heat in the exhaust gas, flowing radially from the combustion element, to the water flowing through the coil. 4 figs.

  1. 土壤源热泵系统地下温度场的热平衡模拟分析%On heat balance simulation analysis of temperature field in ground heat source heat pump system

    Institute of Scientific and Technical Information of China (English)

    宋智军

    2012-01-01

    以成都来福士广场的土壤源热泵工程为例,采用Fluent6.2软件的TransientSolver模块对该项目的地下温度场进行了模拟计算,分别按照土壤源热泵间歇运行模式和连续运行模式来模拟计算地下温度场20年,从模拟结果可以清楚的看到,间歇运行模式下土壤的热平衡状况良好,突出了地下温度场的取热量和排热量的平衡是保证土壤源热泵系统长期稳定运行的重要因素。%Taking the project of the ground source heat pump on Laifushi Square of Chengdu as the example, the paper adopts the Transient Solver Module of the Fluent6.2 software to have the simulation calculation for the underground temperature field of the program, simulates and cal- culates the twenty years of the underground temperature field by adopting the intermittent operation module and its continuous operation one of the ground source heat pump, and shows from the simulation result that the heat balance of the soil in the intermittent operation module has better heat balance, and highlights the balance of the accumulated heat and the extracted heat of the underground temperature field is important for en- suring the long-term and stable operation of the ground source heat pump.

  2. Optimization of ground source heat pumps systems through the implementation of hybrid systems; Optimizacion de las instalaciones de bomba de calor geotermica mediante la implementacion de sistemas hibridos

    Energy Technology Data Exchange (ETDEWEB)

    Magraner, T.; Quilis, M. S.; Martinez, S.

    2009-07-01

    One of the fundamental aspects to consider in the design of a ground heat pump system is the heat balance in the ground since thermal saturation of the ground produces a decreasing of the performance of the system throughout its useful life. The hybrid geothermal system which combined geothermal heat pump system with other systems for generation or dissipation energy are very suitable for balancing the heat exchanger meters needed for the proper functioning of the system, important aspect to reduce costs and achieve attractive return periods of the initial investment. Energesis Ingenieria has developed and implemented in two office buildings, a design of hybrid systems based on the combination of a geothermal heat pump and air-condensed units (dry coolers) that can ensure energy efficiencies comparable to geothermal pure systems, reducing substantially the investment cost. (Author) 5 refs.

  3. Shallow Groundwater Temperatures and the Urban Heat Island Effect: the First U.K City-wide Geothermal Map to Support Development of Ground Source Heating Systems Strategy

    Science.gov (United States)

    Patton, Ashley M.; Farr, Gareth J.; Boon, David P.; James, David R.; Williams, Bernard; Newell, Andrew J.

    2015-04-01

    The first UK city-wide heat map is described based on measurements of groundwater from a shallow superficial aquifer in the coastal city of Cardiff, Wales, UK. The UK Government has a target of reducing greenhouse gas emissions by 80% by 2050 (Climate Change Act 2008) and low carbon technologies are key to achieving this. To support the use of ground source heating we characterised the shallow heat potential of an urban aquifer to produce a baseline dataset which is intended to be used as a tool to inform developers and to underpin planning and regulation. We exploited an existing network of 168 groundwater monitoring boreholes across the city, recording the water temperature in each borehole at 1m depth intervals up to a depth of 20m. We recorded groundwater temperatures during the coldest part of 2014, and repeat profiling of the boreholes in different seasons has added a fourth dimension to our results and allowed us to characterise the maximum depth of seasonal temperature fluctuation. The temperature profiles were used to create a 3D model of heat potential within the aquifer using GOCAD® and the average borehole temperatures were contoured using Surfer® 10 to generate a 2D thermal resource map to support future assessment of urban Ground Source Heat Pumps prospectively. The average groundwater temperature in Cardiff was found to be above the average for England and Wales (11.3°C) with 90% of boreholes in excess of this figure by up to 4°C. The subsurface temperature profiles were also found to be higher than forecast by the predicted geothermal gradient for the area. Potential sources for heat include: conduction from buildings, basements and sub-surface infrastructure; insulation effects of the urban area and of the geology, and convection from leaking sewers. Other factors include recharge inhibition by drains, localised confinement and rock-water interaction in specific geology. It is likely to be a combination of multiple factors which we are hoping

  4. Influence of heat storage mode of domestic hot water on the performance of ground heat exchanger in ground-source heat pump system%卫生热水蓄热方式对地埋管换热性能的影响分析

    Institute of Scientific and Technical Information of China (English)

    王勇; 唐曦

    2012-01-01

    竖埋管地源热泵系统为室内环境控制提供冷热量。在空调工况下,热回收机组可以提供卫生热水。卫生热水的供应在冬夏不同的运行模式下,对地埋管的换热性能影响不同。通过某地源热泵工程设计,分析了冬夏季卫生热水系统在蓄热方式下对地源热泵系统地埋管换热性能的影响。利用卫生热水的蓄热能力,对地埋管换热器在不同工况下的动态换热性能进行了对比分析,并通过数值计算得到了不同运行模式下地埋管的换热性能参数。根据计算结果提出了在该工程负荷特性下的系统调节方式。%The vertical U-tube ground-coupled heat pump system provides cold and heat for the controlling of indoor environment.Under the air-conditioning condition,the vertical U-tube ground-coupled heat pump system with heat recovery can provide domestic hot water.The influence of supplying domestic hot water on the heat transfer performance of ground heat exchangers is different under different operating modes in summer and winter.Through a project design of ground-source heat pump system,the influence of supplying domestic hot water under heat storage mode on the heat transfer performance of ground heat exchangers in summer and winter is respectively analyzed.The dynamic performance of heat exchangers under different working conditions is analyzed,and through numerical calculation,the heat transfer performance parameters of ground heat exchangers under different operating modes are obtained.From the calculation results,the adjusting methods based on the load characteristics of this project represent.

  5. Application Study on Ground Source Heat Pump System%地源热泵系统的应用研究

    Institute of Scientific and Technical Information of China (English)

    李异; 石新会

    2011-01-01

    为了减少一次性能源的使用和对环境的污染,本文以陕西安康市某综合建筑为例,通过对比地源热泵系统和常规空调系统的初投资和运行费用,论证了地源热泵系统的经济性.%In order to reduce the pollution to environment of the primary energy, a packaged building in Ankang is taken for example, and this paper proves the ground-source heal pumps economy by comparing the initial investment and operating costs of ground-source heat pumps system and conventional air conditioning systems.

  6. Quench Protection of DI-BSCCO Coil

    Science.gov (United States)

    Yamaguchi, T.; Ueno, E.; Kato, T.; Hayashi, K.

    Quench protection is one of the most important requirements for the practical application of high-temperature-superconducting (HTS) coils. Quench protection requires that early detection of a developing quench event is followed by rapid reduction of the operating current. However, such quench detection is very difficult because HTS wire produces heat only locally due to the very slow propagation velocity of a normal zone. Excellent high voltage insulation performance is required if the current is to be reduced rapidly in a large-scale superconducting application with very large inductance. Thus it is important to investigate the behavior of coils with various decay time constants, and to detect voltages on very short time scales. This goal remains to be achieved. In the present study we built test coil and a full-scale pole coil for a 20 MW motor for use in experiments on quench protection, and parameterized the relation between the decay time constant and the detecting voltage, using a conventional balance circuit to detect the quench, which was generated by gradually raising the temperature of the coils. The results verify that a balance circuit can be used for quench detection. For example, when the current decay time constant is 4 seconds, the test coil can be protected even with a detecting voltage of 0.15 volts, despite a significant heat production rate of 126 W. We also confirmed that the full-scale pole coil, with a decay time constant of 20 seconds, can be protected with a detecting voltage of 0.06 V.

  7. Commercial applications for COIL

    Science.gov (United States)

    Solomon, Wayne C.; Carroll, David L.; King, D. M.; Fockler, L. A.; Stromberg, D. S.; Sexauer, M.; Milmoe, A.; Sentman, Lee H.

    2000-01-01

    The chemical oxygen-iodine laser (COIL) is a high power, fiber deliverable tool, which can be used for a number of different industrial applications. COIL is of particular interest because of its short fiber deliverable wavelength, high scaleable continuous wave power, and excellent material interaction properties. In past research the University of Illinois at Urbana-Champaign identified and decommissioning and decontamination (DD) of nuclear facilities as a primary focus for COIL technology. DD will be a major challenge in the coming decades. The use of a robotically driven fiber delivered cutting/ablation tool in contaminated areas promises to lower risks to workers for the DD mission. Further, the high cutting speed of COIL will significantly reduce the time required to cut contaminated equipment, reducing costs. The high power of COIL will permit the dismantling of thick stacks of piping and equipment as well as reactor vessels. COIL is very promising for the removal of material from contaminated surfaces, perhaps to depths thicker than an inch. Laser cutting and ablation minimizes dust and fumes, which reduces the required number of high efficiency particulate accumulator filters, thus reducing costly waste disposal. Other potential industrial applications for COIL are shipbuilding, automotive manufacturing, heavy machinery manufacturing, tasks requiring underwater cutting or welding, and there appear to be very promising applications for high powers lasers in the oil industry.

  8. Permafrost thawing in organic Arctic soils accelerated by ground heat production

    DEFF Research Database (Denmark)

    Hollesen, Jørgen; Matthiesen, Henning; Møller, Anders Bjørn;

    2015-01-01

    Decomposition of organic carbon from thawing permafrost soils and the resulting release of carbon to the atmosphere are considered to represent a potentially critical global-scale feedback on climate change1, 2. The accompanying heat production from microbial metabolism of organic material has been...... organic permafrost soils across Greenland and tested the hypothesis that these soils produce enough heat to reach a tipping point after which internal heat production can accelerate the decomposition processes. Results show that the impact of climate changes on natural organic soils can be accelerated...... by microbial heat production with crucial implications for the amounts of carbon being decomposed. The same is shown to be true for organic middens5 with the risk of losing unique evidence of early human presence in the Arctic....

  9. Nanofluids and a method of making nanofluids for ground source heat pumps and other applications

    Science.gov (United States)

    Olson, John Melvin

    2013-11-12

    This invention covers nanofluids. Nanofluids are a combination of particles between 1 and 100 nanometers, a surfactant and the base fluid. The nanoparticles for this invention are either pyrogenic nanoparticles or carbon nanotubes. These nanofluids improve the heat transfer of the base fluids. The base fluid can be ethylene glycol, or propylene glycol, or an aliphatic-hydrocarbon based heat transfer fluid. This invention also includes a method of making nanofluids. No surfactant is used to suspend the pyrogenic nanoparticles in glycols.

  10. The Netherlands. Complex ground source heat drilling for horticultural works; Niederlande. Komplexe Erdwaermebohrung fuer Gartenbaubetriebe

    Energy Technology Data Exchange (ETDEWEB)

    Kilian, Dieter [DrillTec GUT GmbH, Deggendorf (Germany)

    2012-11-01

    For the past six months, the Dutch gardening industry looked to Honselersdijk near Rotterdam with great expectations. There, five market gardening businesses planned to heat their greenhouses with geothermal heat instead of natural gas. After technically complex drilling operations, hot water is now flowing at a rate of up to 50 litres per second; the drilling project remained fascinating to the last for everybody involved.

  11. Investigation on A Ground Source Heat Pump System Integrated With Renewable Sources

    OpenAIRE

    Qian, Defeng; Niu, Fuxin; Kavanaugh, Steven; O'Neill, Zheng

    2016-01-01

    Buildings consumed 40% of the energy and represented 40% of the carbon emissions in the United States. This is more than any other sector of the U.S. economy, including transportation and industry. About 24% of all energy used in the nation is for space heating, cooling and water heating in buildings. Enhancing building efficiency represents one of the easiest, most immediate and most cost effective ways to reduce carbon emissions. One of energy efficient and environment friendly technologies...

  12. Monitoring ground-surface heating during expansion of the Casa Diablo production well field at Mammoth Lakes, California

    Science.gov (United States)

    Bergfeld, D.; Vaughan, R. Greg; Evans, William C.; Olsen, Eric

    2015-01-01

    The Long Valley hydrothermal system supports geothermal power production from 3 binary plants (Casa Diablo) near the town of Mammoth Lakes, California. Development and growth of thermal ground at sites west of Casa Diablo have created concerns over planned expansion of a new well field and the associated increases in geothermal fluid production. To ensure that all areas of ground heating are identified prior to new geothermal development, we obtained high-resolution aerial thermal infrared imagery across the region. The imagery covers the existing and proposed well fields and part of the town of Mammoth Lakes. Imagery results from a predawn flight on Oct. 9, 2014 readily identified the Shady Rest thermal area (SRST), one of two large areas of ground heating west of Casa Diablo, as well as other known thermal areas smaller in size. Maximum surface temperatures at 3 thermal areas were 26–28 °C. Numerous small areas with ground temperatures >16 °C were also identified and slated for field investigations in summer 2015. Some thermal anomalies in the town of Mammoth Lakes clearly reflect human activity.Previously established projects to monitor impacts from geothermal power production include yearly surveys of soil temperatures and diffuse CO2 emissions at SRST, and less regular surveys to collect samples from fumaroles and gas vents across the region. Soil temperatures at 20 cm depth at SRST are well correlated with diffuse CO2 flux, and both parameters show little variation during the 2011–14 field surveys. Maximum temperatures were between 55–67 °C and associated CO2 discharge was around 12–18 tonnes per day. The carbon isotope composition of CO2 is fairly uniform across the area ranging between –3.7 to –4.4 ‰. The gas composition of the Shady Rest fumarole however has varied with time, and H2S concentrations in the gas have been increasing since 2009.

  13. Integration of solar heat storage in the ground floor; Bygningsintegreret varmelagring af solvarme i terraendaek

    Energy Technology Data Exchange (ETDEWEB)

    Weitzmann, P.; Holck, O.; Svendsen, S.

    2001-07-01

    In this report the thermal properties of heat storage of solar heating in floors is examined. The floor examined is built using two decks, where the lower can be used for heat storage. It is the purpose of the work that has been carried out, to be able to quantify the potential for a reduction of the heating demand in a house, through the use of heat storage of solar heating. The report starts out with an introduction to the problem that is to be examined, namely to perform detailed calculations of the temperature and heat flows in floors. A description of the theory for the implementation of the model for solar collector, solar tank, floor, foundation and control strategies, can be found. The model described here has been implemented into the programming language Matlab and Simulink. Especially the model of the floor is described in great detail. The section begins with a description of the floor construction. It is then described how the floor construction is implemented into a detailed finite element model, and converted into a less detailed RC-model, where the temperature is calculated only in a few points. Each of the points had a heat capacity, and between the points a thermal resistance is included. The reason for using a RC-model is, that it proved impossible to do yearly calculations using the finite element model because of unacceptably long calculation times. Instead the procedure for the conversion between the two models is shown. After the conversion results from the two methods are compared to estimate the error introduced by this conversion to a less detailed model. The two methods are found to differ only by around 5%. The coefficients to be used in the RC-model are shown for seven different layouts of the floor concerning pipe spacing, distribution of insulation, thickness of heat storage layer and type of heat storage layer (sand or concrete). A number of different control strategies for the distribution of flow in solar tank and heat storage

  14. Satellite and ground-based sensors for the Urban Heat Island analysis in the city of Rome

    DEFF Research Database (Denmark)

    Fabrizi, Roberto; Bonafoni, Stefania; Biondi, Riccardo

    2010-01-01

    In this work, the trend of the Urban Heat Island (UHI) of Rome is analyzed by both ground-based weather stations and a satellite-based infrared sensor. First, we have developed a suitable algorithm employing satellite brightness temperatures for the estimation of the air temperature belonging...... to the layer of air closest to the surface. UHI spatial characteristics have been assessed using air temperatures measured by both weather stations and brightness temperature maps from the Advanced Along Track Scanning Radiometer (AATSR) on board ENVISAT polar-orbiting satellite. In total, 634 daytime...... and nighttime scenes taken between 2003 and 2006 have been processed. Analysis of the Canopy Layer Heat Island (CLHI) during summer months reveals a mean growth in magnitude of 3-4 K during nighttime and a negative or almost zero CLHI intensity during daytime, confirmed by the weather stations. © 2010...

  15. First assembly phase for the ATLAS toroid coils

    CERN Multimedia

    Patrice Loïez

    2003-01-01

    The ATLAS barrel toroid system consists of eight coils, each of axial length 25.3 m, assembled radially and symmetrically around the beam axis. The coils are of a flat racetrack type with two double-pancake windings made of 20.5 kA aluminium-stabilized niobium-titanium superconductor. In the first phase of assembly, the two 'pancakes' are packed into their vacuum vessel. This is done using bladders filled with resin and glass microbeads under pressure. The resin is heated and, once cooled, holds the pancakes in place. The operation has to be performed on both sides of the coil, which necessitated a special technique to turn the coils over and then transport them to the heating table. Photos 01, 02, 03: Use of the overhead travelling crane to hoist the coil up and then tilt it over, the coil frame's metal feet being used as rotational pivots, supporting half the coil's weight. Once it has been turned over, the coil, now with only half the frame, is transported to the heating table using a special lifting gant...

  16. 地源热泵与混合式地源热泵应用对比分析%Comparative Analysis of Ground Source Heat Pumps and Hybrid Ground Source Heat Pump

    Institute of Scientific and Technical Information of China (English)

    陈正顺

    2014-01-01

    Ground Source Heat Pumps(GSHPs) and Hybrid Ground Source Heat Pumps(HGSHPs) in-stalled in several public buildings are compared. The annual energy consumption of buildings are simulated respectively, taking selection calculation of GSHPs and HGSHPs, as well as the initial investment, annual operating costs and the comprehensive fee of two programs.%对合肥几种常见公共建筑已完全使用地埋管换热器的地源热泵系统与混合式地源热泵系统进行了比较。分别对各类型建筑进行了全年能耗模拟,对地源热泵、混合式地源热泵系统进行了选型计算,并对比了两种方案的初投资、年运行费用、年综合费用。

  17. Comparison of the Calculations Results of Heat Exchange Between a Single-Family Building and the Ground Obtained with the Quasi-Stationary and 3-D Transient Models. Part 2: Intermittent and Reduced Heating Mode

    Directory of Open Access Journals (Sweden)

    Staszczuk Anna

    2017-03-01

    Full Text Available The paper provides comparative results of calculations of heat exchange between ground and typical residential buildings using simplified (quasi-stationary and more accurate (transient, three-dimensional methods. Such characteristics as building’s geometry, basement hollow and construction of ground touching assemblies were considered including intermittent and reduced heating mode. The calculations with simplified methods were conducted in accordance with currently valid norm: PN-EN ISO 13370:2008. Thermal performance of buildings. Heat transfer via the ground. Calculation methods. Comparative estimates concerning transient, 3-D, heat flow were performed with computer software WUFI®plus. The differences of heat exchange obtained using more exact and simplified methods have been specified as a result of the analysis.

  18. Flexible heating head for induction heating

    Science.gov (United States)

    Fox, Robert L. (Inventor); Johnson, Samuel D. (Inventor); Coultrip, Robert H. (Inventor); Phillips, W. Morris (Inventor)

    1993-01-01

    An induction heating head includes a length of wire having first and second opposite ends and being wound in a flat spiral shape to form an induction coil, a capacitor connected to the first and second ends of the wire, the induction coil and capacitor defining a tank circuit, and a flexible, elastomeric body molded to encase the induction coil. When a susceptor is placed in juxtaposition to the body, and the tank circuit is powered, the susceptor is inductively heated.

  19. A periodic table of coiled-coil protein structures.

    Science.gov (United States)

    Moutevelis, Efrosini; Woolfson, Derek N

    2009-01-23

    Coiled coils are protein structure domains with two or more alpha-helices packed together via interlacing of side chains known as knob-into-hole packing. We analysed and classified a large set of coiled-coil structures using a combination of automated and manual methods. This led to a systematic classification that we termed a "periodic table of coiled coils," which we have made available at http://coiledcoils.chm.bris.ac.uk/ccplus/search/periodic_table. In this table, coiled-coil assemblies are arranged in columns with increasing numbers of alpha-helices and in rows of increased complexity. The table provides a framework for understanding possibilities in and limits on coiled-coil structures and a basis for future prediction, engineering and design studies.

  20. The construction and crack control of floor heating concrete ground%地暖混凝土地面施工和裂缝控制

    Institute of Scientific and Technical Information of China (English)

    郭运勇; 刘国辉; 岳钊; 曹霞

    2015-01-01

    Through the analysis and summary on the construction procedure and process of a engineering floor heating,this paper summarized the causes,control measures etc. of floor heating concrete ground cracks,so as to effectively control the floor heating ground cracks.%通过对某工程地暖工程施工工序和工艺进行分析和归纳,总结了地暖混凝土地面裂缝的产生原因、控制措施等,以有效控制地暖地面产生裂缝。

  1. LHCb magnet coils arrive

    CERN Multimedia

    Maximilien Brice

    2003-01-01

    Each of the two coils for the LHCb magnet comprises 15 individual monolayer 'pancakes' of identical trapezoidal racetrack shape, and is bent at 45 degrees on the two transverse sides. Each pancake consists of eight turns of conductor, wound from a single length (approx. 290 m) of extruded aluminium. The coils have arrived at CERN; one of them is seen here being unloaded above the LHCb experimental cavern.

  2. Improvement of Prediction Method for Strip Coiling Temperature

    Institute of Scientific and Technical Information of China (English)

    YU Qing-bo; WANG Zhao-dong; WANG Zhe-ying; LIU Xiang-hua; WANG Guo-dong

    2003-01-01

    In order to improve the control precision of strip coiling temperature for hot strip mill, the BP neural network was combined with mathematical model to calculate convective heat-transfer coefficient of laminar flow cooling. The off-line calculated results indicate that the standard deviation of coiling temperature prediction is reduced by 22.84 % with the convective heat-transfer coefficient calculated by BP neural network. The prospects of this method for on-line application are bright. This method is more helpful to increasing the control precision of coiling temperature for hot strip steel.

  3. Coiling of yield stress fluids

    NARCIS (Netherlands)

    Y. Rahmani; M. Habibi; A. Javadi; D. Bonn

    2011-01-01

    We present an experimental investigation of the coiling of a filament of a yield stress fluid falling on a solid surface. We use two kinds of yield stress fluids, shaving foam and hair gel, and show that the coiling of the foam is similar to the coiling of an elastic rope. Two regimes of coiling (el

  4. 包头市某地源热泵工程设计%Ground-source heat pump project design in Baotou

    Institute of Scientific and Technical Information of China (English)

    张士领

    2014-01-01

    Ground heat exchanger system is the key to the smooth running of the ground-source heat pump system.Through the ground-source heat pump system design idea,the ground heat exchanger system selection calculation,and the project cooling and heating load comparative analysis,adopts the gas boiler as the system peak load heat source.To reduce the energy consumption,combined with the characteristics of radiant cooling terminal,supplies the ground source water cooling directly in transition seasons,and obtains good energy conservation effect.%地埋管换热系统是整个地源热泵系统能否良好运行的关键。通过对地源热泵系统设计思路、地埋管换热系统选择计算、工程冷热负荷的对比分析,采用燃气锅炉作为系统的调峰热源。为减少能源消耗,结合工程末端为辐射供冷的特点,在过渡季节使用地源水直接供冷,取得了较好的节能效果。

  5. Simulation and design of ground source heat pump systems%地源热泵系统的模拟与设计

    Institute of Scientific and Technical Information of China (English)

    JeffreyD.Spitler; CenkYavuzturk; 等

    2003-01-01

    总结了近年来地源热泵系统的模拟和设计方面的研究和进展.首先给出了地源热泵系统各部件建模方面的进展,包括竖直埋管地热换热器、单井循环系统以及在地源热泵混合系统中采用的几种辅助散热装置.其次,讨论现场测定深层岩土热物性的技术.第三,介绍竖直埋管地热换热器的设计方法.最后,给出在设计地源热泵系统中采用系统模拟的几个应用实例.%This paper gives an overview of recent research and developments in ground source heat pump system simulation and design. First, developments related to modeling of components of the Ground Source Heat Pump (GSHP) system are presented-vertical ground loop heat exchanger, water source heat pump, standing column well, and several types of supplemental heat rejecters used in hybrid GSHP systems. Second, in situ measurement techniques for ground thermal properties are discussed. Third, a methodology for the design of the vertical ground loop heat exchanger is introduced. Last, several applications of using system simulation in the design of GSHP systems are presented.

  6. An Environmental and Economic Assessment for Selecting the Optimal Ground Heat Exchanger by Considering the Entering Water Temperature

    Directory of Open Access Journals (Sweden)

    Jimin Kim

    2015-07-01

    Full Text Available In order to solve environmental problems such as global warming and resource depletion in the construction industry, interest in new renewable energy (NRE systems has increased. The ground source heat pump (GSHP system is the most efficient system among NRE systems. However, since the initial investment cost of the GSHP is quite expensive, a feasibility study needs to be conducted from the life-cycle perspective. Meanwhile, the efficiency of GSHP depends most significantly on the entering water temperature (EWT of the ground heat exchanger (GHE. Therefore, this study aims to assess the environmental and economic effects of the use of GHE for selecting the optimal GHE. This study was conducted in three steps: (i establishing the basic information and selecting key factors affecting GHE performances; (ii making possible alternatives of the GHE installation by considering EWT; and (iii using life-cycle assessment and life-cycle cost, as well as comprehensive evaluation of the environmental and economic effects on the GHE. These techniques allow for easy and accurate determination of the optimal design of the GHE from the environmental and economic effects in the early design phase. In future research, a multi-objective decision support model for the GSHP will be developed.

  7. Linear Rogowski coil

    Science.gov (United States)

    Nassisi, V.; Delle Side, D.

    2017-02-01

    Nowadays, the employment and development of fast current pulses require sophisticated systems to perform measurements. Rogowski coils are used to diagnose cylindrical shaped beams; therefore, they are designed and built with a toroidal structure. Recently, to perform experiments of radiofrequency biophysical stresses, flat transmission lines have been developed. Therefore, in this work we developed a linear Rogowski coil to detect current pulses inside flat conductors. The system is first approached by means of transmission line theory. We found that, if the pulse width to be diagnosed is comparable with the propagation time of the signal in the detector, it is necessary to impose a uniform current as input pulse, or to use short coils. We further analysed the effect of the resistance of the coil and the influence of its magnetic properties. As a result, the device we developed is able to record pulses lasting for some hundreds of nanoseconds, depending on the inductance, load impedance, and resistance of the coil. Furthermore, its response is characterized by a sub-nanosecond rise time (˜100 ps). The attenuation coefficient depends mainly on the turn number of the coil, while the fidelity of the response depends both on the magnetic core characteristics and on the current distribution along the plane conductors.

  8. How to Ensure Long -term Stable Operation of Ground Source Heat Pump System for Heating Biogas Digester%如何保证地源热泵式沼气池加温系统长期稳定运行

    Institute of Scientific and Technical Information of China (English)

    张迪; 石惠娴; 朱洪光; 雷勇; 王卓

    2011-01-01

    针对地源热泵式沼气池加温系统中出现的冬夏季取排热不平衡从而影响其长期稳定运行的问题,本文在采取控制运行方式、增加辅助热源和蓄热系统解决方法的分析基础上,从充分利用可再生能源和地源热泵设备的角度出发,提出热泵供热和制冷互补模式与太阳能-地源热泵多功能互补模式,并对其可行性进行分析.%To address the problem of heat imbalance of soil between winter and summer led by ground source heat pump system for heating biogas digester and to ensure the system running more stably, effectively in a long time , the paper presents the advantages and disadvantages of controlling operation model and solar assisted ground source heat pump system with heat storage.What's more, the paper also proposes complementary models of heafing and cooling of heat pump and multifunctional system integrationg solar energy with ground source heat pump, and analyses the possibility of the above two solutions from the perspective of making full use of renewable energy and the equipment of ground soure heat pump.

  9. Field Demonstration of Ground-Source Integrated Heat Pump - Final Report

    Energy Technology Data Exchange (ETDEWEB)

    Baxter, Van D. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Munk, Jeffrey D. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Gehl, Anthony C. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States)

    2016-09-01

    Reducing energy consumption in buildings is key to reducing or limiting the negative environmental impacts from the building sector. According to the United States (U.S.) Energy Information Administration (EIA), in 2013, commercial buildings consumed 18.1 quads of primary energy, which was 18.6% of the total U.S. primary energy consumption. The primary energy consumption in the commercial sector is projected to increase by 2.8 quads from 2013 to 2040, the second largest increase after the industrial sector. Further space heating, space cooling, and ventilation (HVAC) services accounted for 31% of the energy consumption in commercial buildings. The technical objective of this project is to demonstrate the capability of the new GS-IHP system to reduce overall energy use for space heating, space cooling, and water heating by at least 45% vs. a conventional electric RTU and electric WH in a light commercial building application. This project supports the DOE-Building Technologies Office (BTO) goals of reducing HVAC energy use by 20% and water heating by 60% by 2030.

  10. Temperature distributions in pavement and bridge slabs heated by using vertical ground-source heat pump systems - doi: 10.4025/actascitechnol.v35i4.15712

    Directory of Open Access Journals (Sweden)

    Asım Balbay

    2013-10-01

    Full Text Available Temperature distribution which occurs in pavement and bridge slabs heated for de-icing and snow melting during cold periods is determined by using vertical ground-source heat pump (GSHP systems with U-tube ground heat exchanger (GHE. The bridge and pavement models (slabs for de-icing and snow melting were constructed. A three-dimensional finite element model (FEM was developed to simulate temperature distribution of bridge slab (BS and pavement slab (PS. The temperature distribution simulations of PS and BS were conducted numerically by computational fluid dynamics (CFD program named ‘Fluent’. Congruence between the simulations and experimental data was determined.   

  11. Construction Technology of Soil Source Heat Exchanger of Ground Source Heat Pump%地源热泵土壤源换热器的施工技术

    Institute of Scientific and Technical Information of China (English)

    程金明; 王巧真

    2007-01-01

    地源热泵(Ground Source Heat Pump, GSHP)作为最有发展潜力的热泵技术在各级政府的积极推介下发展迅速,但由于地源换热器施工安装成本高,技术的发展遇到了很大的阻力.探讨了土壤源换热器施工技术和土壤源换热器的热平衡问题,力图提高土源换热器施工技术,降低地源热泵成本,促进该技术的推广应用.

  12. Bioaerosol deposition on an air-conditioning cooling coil

    Science.gov (United States)

    Wu, Yan; Chen, Ailu; Luhung, Irvan; Gall, Elliott T.; Cao, Qingliang; Chang, Victor Wei-Chung; Nazaroff, William W.

    2016-11-01

    This study is concerned with the role of a fin-and-tube heat exchanger in modifying microbial indoor air quality. Specifically, depositional losses of ambient bioaerosols and particles onto dry (not cooled) and wet (cool) coil surfaces were measured for different airspeeds passing through the test coil. Total, bacterial and fungal DNA concentrations in condensate water produced by a wet coil were also quantified by means of fluorescent dsDNA-binding dye and qPCR assays. Results revealed that the deposition of bioaerosols and total particles is substantial on coil surfaces, especially when wet and cool. The average deposition fraction was 0.14 for total DNA, 0.18 for bacterial DNA and 0.22 for fungal DNA on the dry coil, increasing to 0.51 for total DNA, 0.50 for bacterial DNA and 0.68 for fungal DNA on the wet coil. Overall, as expected, deposition fractions increased with increasing particle size and increasing airspeed. Deposited DNA was removed from the cooling coil surfaces through the flow of condensing water at a rate comparable to the rate of direct deposition from air. A downward trend of bacterial and fungal DNA measured in condensate water over time provides suggestive evidence of biological growth on heat exchangers during nonoperational times of a ventilation system. This investigation provides new information about bioaerosol deposition onto a conventional fin-and-tube cooling coil, a potentially important factor influencing indoor exposure to microbial aerosols in air-conditioned buildings.

  13. 土壤含水率及渗流对土壤源热泵影响研究进展%Research development on the impact of ground moisture content and seepage upon ground source heat pump

    Institute of Scientific and Technical Information of China (English)

    段妍; 晋华; 刘虎

    2012-01-01

    主要介绍了土壤含水率和地下水渗流两个主要水文地质因素,具体分析了两因素在实验和数值模拟方面对土壤源热泵地埋管换热能力的影响,并指出了土壤源热泵在水文地质因素研究方面存在的问题和今后发展的方向,为土壤源热泵运行的稳定性及经济效益的最大化提供保障。%The thesis mainly introduces ground moisture content and underground water seepage,specifically analyzes the impact of ground moisture content and underground water seepage upon ground source heat pump heat-exchanging ability in the two aspects of experiments and numerical simulation,and points out existing problems and development trend of ground source heat pump in the angle of hydrogeology,which has provided maximum guarantee for stable and economic operation of ground source heat pump.

  14. Composite ground source heat pump used in scattered oilfield%复合地源热泵在油田边零井中的应用

    Institute of Scientific and Technical Information of China (English)

    刘伟; 杨鹏; 侯静

    2012-01-01

    In the Remote areas, oil is stored in storage tanks, and needed to be heated in order to output. Compared with fuel, gas boilers and electric heating system, ground source heat pump heating system has the features as safe, energy saving, environmentally friendly. But a separate ground source heat pump sys- tem only take the heat from soil, not release heat to the soil. To overcome this shortcoming the paper pro- poses solar--assisted ground-source heat pump system. Through the use of trnsys software simulation, it is proved that this system is feasible, and should be promoted.%油田边零井中的原油储存在储油罐中,需要加热才能输出,地源热泵加热系统较燃油、燃气锅炉和电加热系统,具有安全,节能,环保的特点,但是单独地源热泵系统地下地埋管只取热不放热,为了克服这个缺点,提出了太阳能辅助地源热泵系统,通过运用trnsys软件模拟,证明此系统用于油田边零井是可行的,值得推广的。

  15. Dirty air conditioners: Energy implications of coil fouling

    Energy Technology Data Exchange (ETDEWEB)

    Siegel, Jeffrey; Walker, Iain; Sherman, Max

    2002-03-01

    Residential air conditioning is responsible for a substantial amount of peak electrical demand and energy consumption throughout most of the United States. Coil fouling, the deposition of indoor dusts and other particulate matter on evaporator heat exchangers, increases system pressure drop and, correspondingly, decreases system air flow and air conditioner performance. In this paper, we apply experimental and simulation results describing particle deposition on evaporator coils as well as research about indoor particle and dust concentrations to determine coil fouling rates. The results suggest that typical coils foul enough to double evaporator pressure drop in about 7.5 years, much sooner than the expected 15-30 year life time for an evaporator coil. The most important parameters in determining coil fouling times are the efficiency of the filter and indoor particle concentrations, although filter bypass and duct and coil design are important as well. The reduced air flows that result from coil fouling cause typical efficiency and capacity degradations of less than 5%, however they can be much greater for marginal systems or extreme conditions. These energy issues, as well as possible indoor air quality issues resulting from fouling by biological aerosols, suggest that regular coil cleaning to ameliorate low flow and the elimination of filter bypass should be an important part of residential air conditioning commissioning and maintenance practices.

  16. The Analysis of Ground Source Heat Pump Applied in Mianyang City%地源热泵在绵阳地区的应用分析

    Institute of Scientific and Technical Information of China (English)

    刘东; 蒋斌; 韩如冰; 邹国荣

    2013-01-01

      介绍了地源热泵的工作原理,并结合绵阳地区的地质情况及地源热泵系统形式,分析了地源热泵技术在绵阳地区的应用方式,并针对地表水、地下水和地下耦合地源热泵系统的可行性进行了分析和说明,为地源热泵技术在绵阳地区的工程应用提供参考。%This paper introduced the operational principle of ground source heat pump. Based on the geologic environment of Mianyang city and the ground source heat pump forms, the application of different ground source heat pump were compared. And analyses the feasibility of surface water,ground water and underground coupling source heat pump in Mianyang city. This paper can provide the reference for the ground source heat pump engineering application in Mianyang city.

  17. Coiled coils and SAH domains in cytoskeletal molecular motors.

    Science.gov (United States)

    Peckham, Michelle

    2011-10-01

    Cytoskeletal motors include myosins, kinesins and dyneins. Myosins move along tracks of actin filaments, whereas kinesins and dyneins move along microtubules. Many of these motors are involved in trafficking cargo in cells. However, myosins are mostly monomeric, whereas kinesins are mostly dimeric, owing to the presence of a coiled coil. Some myosins (myosins 6, 7 and 10) contain an SAH (single α-helical) domain, which was originally thought to be a coiled coil. These myosins are now known to be monomers, not dimers. The differences between SAH domains and coiled coils are described and the potential roles of SAH domains in molecular motors are discussed.

  18. Research Progress of Composite Ground Source Heat Pump Air Conditioning System%复合地源热泵系统的研究进展探讨

    Institute of Scientific and Technical Information of China (English)

    程晋洋; 朱彩霞; 李晓光

    2015-01-01

    The paper mainly introduces the advantages of ground source heat pump and its development trend, the classification and working principle of composite ground source heat pump depend on various forms of cold and heat source. The research status both at home and abroad in different times are expounded, analyzing the reason of heat imbalance and coefficient of performance reduction caused by long-term use of ground source heat pump system. A series of recommendations are proposed to improve the performance of ground source heat pump as the direction for the future research.%主要介绍地源热泵的优点及其发展趋势,以及不同冷热源形式的复合地源热泵的分类及其工作原理。探讨了不同时期复合地源热泵国内外的研究现状,分析了地源热泵长期使用系统热量失衡、COP 减小的原因,并提出一些改善地源热泵性能的建议,为其今后的研究提供方向。

  19. Exergy cost analysis of ground source heat pump system%土壤源热泵系统的火用成本分析

    Institute of Scientific and Technical Information of China (English)

    龚光彩; 冯启辉; 苏欢; 徐春雯

    2011-01-01

    在对火用分析与经济学原理研究的基础上,利用火用成本分析方法,建立了土壤源热泵系统的(火用) 成本分析模型.以实际的建筑空调系统为背景,运用所建火用成本分析模型与能量成本分析方法,对土壤源热泵系统与风冷热泵系统进行了对比分析计算,并以空气源热泵为基础对土壤源热泵进行了敏感性分析.对土壤源热泵的实际应用具有指导意义.%Based on the study of the exergy analysis and economics theory, an exergy cost analysis model of ground source heat pump system was established by using the exergy cost analysis method. With the background of an actual building air - conditioning system, the ground source heat pump system and the air source heat pump system were calculated by using exergy cost analysis model and energy cost analysis method. And the sensitivity analysis method was used in the exergy cost of ground source heat pump basing on air source heat pump. The analysis method has guiding significance for practical application of ground source heat pump.

  20. 铁路站房地源热泵系统工程热平衡分析%Analysis on Heat Balance of Ground Source Heat Pump System in Railway Station

    Institute of Scientific and Technical Information of China (English)

    沈德安

    2013-01-01

    Abstract:In regard to an actual railway station,based on its design circumstance of air-condition heating system and its testing report of ground heat transfer characteristics,the ground source heat pump system was adopted as its cold and heat source.Considering the need for heat balance of the ground source heat pump system,this thesis analyzes the two different schemes used in railway station buildings:the one is a ground source heat pump system assisted by boiler,and the other is a coupled system of solar energy with ground source heat pump.And then respectively for both schemes,this thesis calculates the required capacity of ground source heat pump unit and the required design scale of ground heat exchanger.This thesis also discusses how to achieve the cold and heat balance for the two different schemes,and analyzes each characteristics and applicability in actual projects.Finally this thesis points out:it is necessary to use suitable and customized heat balance modes for different projects on the basis of local conditions.%结合具体工程,根据某车站空调采暖系统设计工况及该工程地埋管换热特性测试报告,采用地源热泵系统作为冷热源.考虑地源热泵系统的冷热平衡需要,分析采用地源热泵+锅炉辅助系统及太阳能地源热泵耦合系统两种不同热平衡方案用于铁路站房,计算各自需要的热泵机组容量及室外埋管换热器具体设计规模.详细介绍两种系统的冷热平衡方式,并对各自特点及工程运用进行论述,提出在具体工程中因地制宜,应根据不同情况,采用合适的系统热平衡方式.

  1. Case Study for the ARRA-funded Ground Source Heat Pump Demonstration at Denver Museum of Nature & Science

    Energy Technology Data Exchange (ETDEWEB)

    Im, Piljae [ORNL; Liu, Xiaobing [ORNL

    2016-09-01

    High initial costs and lack of public awareness of ground-source heat pump (GSHP) technology are the two major barriers preventing rapid deployment of this energy-saving technology in the United States. Under the American Recovery and Reinvestment Act (ARRA), 26 GSHP projects were competitively selected and carried out to demonstrate the benefits of GSHP systems and innovative technologies for cost reduction and/or performance improvement. This report highlights the findings of a case study of one such GSHP demonstration projects that uses a recycled water heat pump (RWHP) system installed at the Denver Museum of Nature & Science in Denver, Colorado. The RWHP system uses recycled water from the city’s water system as the heat sink and source for a modular water-to-water heat pump (WWHP). This case study was conducted based on the available measured performance data from December 2014 through August 2015, utility bills of the building in 2014 and 2015, construction drawings, maintenance records, personal communications, and construction costs. The annual energy consumption of the RWHP system was calculated based on the available measured data and other related information. It was compared with the performance of a baseline scenario— a conventional VAV system using a water-cooled chiller and a natural gas fired boiler, both of which have the minimum energy efficiencies allowed by ASHRAE 90.1-2010. The comparison was made to determine energy savings, operating cost savings, and CO2 emission reductions achieved by the RWHP system. A cost analysis was performed to evaluate the simple payback of the RWHP system. Summarized below are the results of the performance analysis, the learned lessons, and recommended improvement in the operation of the RWHP system.

  2. Case Study for the ARRA-funded Ground Source Heat Pump Demonstration at Denver Museum of Nature & Science

    Energy Technology Data Exchange (ETDEWEB)

    Im, Piljae [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States). Energy and Transportation Science Division; Liu, Xiaobing [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States). Energy and Transportation Science Division

    2015-11-30

    High initial costs and lack of public awareness of ground-source heat pump (GSHP) technology are the two major barriers preventing rapid deployment of this energy-saving technology in the United States. Under the American Recovery and Reinvestment Act (ARRA), 26 GSHP projects were competitively selected and carried out to demonstrate the benefits of GSHP systems and innovative technologies for cost reduction and/or performance improvement. This report highlights the findings of a case study of one such GSHP demonstration projects that uses a recycled water heat pump (RWHP) system installed at the Denver Museum of Nature & Science in Denver, Colorado. The RWHP system uses recycled water from the city’s water system as the heat sink and source for a modular water-to-water heat pump (WWHP). This case study was conducted based on the available measured performance data from December 2014 through August 2015, utility bills of the building in 2014 and 2015, construction drawings, maintenance records, personal communications, and construction costs. The annual energy consumption of the RWHP system was calculated based on the available measured data and other related information. It was compared with the performance of a baseline scenario— a conventional VAV system using a water-cooled chiller and a natural gas fired boiler, both of which have the minimum energy efficiencies allowed by ASHRAE 90.1-2010. The comparison was made to determine energy savings, operating cost savings, and CO2 emission reductions achieved by the RWHP system. A cost analysis was performed to evaluate the simple payback of the RWHP system. Summarized below are the results of the performance analysis, the learned lessons, and recommended improvement in the operation of the RWHP system.

  3. The Effect of Heating on the Degradation of Ground Laboratory and Space Irradiated Teflon(r) FEP

    Science.gov (United States)

    deGroh, Kim K.; Martin, Morgana

    2002-01-01

    The outer most layer of the multilayer insulation (MLI) blankets on the Hubble Space Telescope (HST) is back surface aluminized Teflon(R) FEP (fluorinated ethylene propylene). As seen by data collected after each of the three servicing missions and as observed during the second servicing mission (SM2), the FEP has become embrittled in the space environment, leading to degradation of the mechanical properties and severe on-orbit cracking of the FEP. During SM2, a sample of aluminized-FEP was retrieved from HST that had cracked and curled, exposing its aluminum backside to space. Because of the difference in optical properties between FEP and aluminum, this insulation piece reached 200 C on-orbit, which is significantly higher than the nominal MLI temperature extreme of 50 C. This piece was more brittle than other retrieved material from the first and third servicing missions (SM1 and SM3A, respectively). Due to this observation and the fact that Teflon thermal shields on the solar array bi-stems were heated on-orbit to 130 C, experiments have been conducted to determine the effect of heating on the degradation of FEP that has been irradiated in a ground laboratory facility or in space on HST. Teflon FEP samples were X-ray irradiated in a high vacuum facility in order to simulate the damage caused by radiation in the space environment. Samples of pristine FEP, X-ray irradiated FEP and FEP retrieved from the HST during SM3A were heat treated from 50 to 200 C at 25 intervals in a high vacuum facility and then tensile tested. In addition, samples were tested in a density gradient column to determine the effect of the radiation and heating on the density of FEP. Results indicate that although heating does not degrade the tensile properties of non-irradiated Teflon, there is a significant dependence of the percent elongation at failure of irradiated Teflon as a function of heating temperature. Irradiated Teflon was found to undergo increasing degradation in the elongation

  4. Technical Feasibility Study for Deployment of Ground-Source Heat Pump Systems: Portsmouth Naval Shipyard -- Kittery, Maine

    Energy Technology Data Exchange (ETDEWEB)

    Hillesheim, M.; Mosey, G.

    2014-11-01

    The U.S. Environmental Protection Agency (EPA) Office of Solid Waste and Emergency Response, in accordance with the RE-Powering America's Lands initiative, engaged the U.S. Department of Energy's (DOE) National Renewable Energy Laboratory (NREL) to conduct feasibility studies to assess the viability of developing renewable energy generating facilities on contaminated sites. Portsmouth Naval Shipyard (PNSY) is a United States Navy facility located on a series of conjoined islands in the Piscataqua River between Kittery, ME and Portsmouth, NH. EPA engaged NREL to conduct a study to determine technical feasibility of deploying ground-source heat pump systems to help PNSY achieve energy reduction goals.

  5. 地源热泵技术的推广与应用%The Promotion and Application of Ground Source Heat Pump Technology

    Institute of Scientific and Technical Information of China (English)

    张斌; 张力; 田忠春

    2013-01-01

      阐述了地源热泵的发展历程、工作原理、地源热泵种类和技术特点,例举了地源热泵技术在工程中的应用实例,分析了目前存在的需要注意的问题,对地源热泵技术的发展前景进行了展望。%In this text, several problems on the ground source heat pump are researched, such as its development history, principle of operation, the kind of ground source heat pump, technical characteristics and application examples of engineering technology. The paper also analyses the current problems and look further into the future of ground source heat pump.

  6. TESLA Coil Research

    Science.gov (United States)

    1992-05-01

    Sloan’s work was actually predated by the earlier work of Nikola Tesla . Sloan mistakenly identified " Tesla Coils" as lumped tuned resonators. The...Lefvw WsnJ L REPORT o]i 3. REPRT TYPE AND OATES COVEIRD May 1992 Special/Aug 1992 - May 1992 Z TITLE AND 5U§nUT S. FUNDING NUMIHRS Tesla Coil Research...STATEMENT 1211. ’ISTRIUUTION COOD Approved for public release; dis~ribution is unlimited 13. ABSTRACT (Masrmum 200 worw) High repetition rate Tesla

  7. Meiosis specific coiled-coil proteins in Shizosaccharomyces pombe

    Directory of Open Access Journals (Sweden)

    Okuzaki Daisuke

    2007-05-01

    Full Text Available Abstract Many meiosis-specific proteins in Schizosaccharomyces pombe contain coiled-coil motifs which play essential roles for meiotic progression. For example, the coiled-coil motifs present in Meu13 and Mcp7 are required for their function as a putative recombinase cofactor complex during meiotic recombination. Mcp6/Hrs1 and Mcp5/Num1 control horsetail chromosome movement by astral microtubule organization and anchoring dynein respectively. Dhc1 and Ssm4 are also required for horsetail chromosome movement. It is clear from these examples that the coiled-coil motif in these proteins plays an important role during the progression of cells through meiosis. However, there are still many unanswered questions on how these proteins operate. In this paper, we briefly review recent studies on the meiotic coiled-coil proteins in Sz. pombe.

  8. On-Orbit Daytime Solar Heating Effects: A Comparison of Ground Chamber Arcing Results

    Science.gov (United States)

    Galofaro, J.; Vayner, B.; Ferguson, D.

    2004-01-01

    The purpose of the current experiment is to make direct comparisons between the arcing results obtained from the diffusion pumped vertical chamber and our newly renovated Teney vacuum chamber which is equipped with a cryogenic pump. Recall that the prior reported results obtained for the Vertical chamber were nominal at best, showing only a slight reduction in the arc rate after five heating cycles at the lower bias potentials and virtually no changes at high potential biases. It was concluded that the vertical chamber was unable to remove enough water vapor from the chamber to adequately test the arcing criterion. Because the cryo-pumped Teney chamber has a ten times better pumping speed, (40,000 liters per sec compared to 4,000 liters per sec for the diffusion pumped vertical chamber), a decision was made to retest that experiment in both the Teney and Vertical vacuum chambers. A comparison of the various data is presented with encouraging results.

  9. On Orbit Daytime Solar Heating Effects: A Comparison of Ground Chamber Arcing Results

    Science.gov (United States)

    Galofaro, J.; Vayner, B.; Ferguson, D.

    2004-01-01

    The purpose of the current experiment is to make direct comparisons between the arcing results obtained from the diffusion pumped vertical chamber and our newly renovated Teney vacuum chamber which is equipped with a cryogenic pump. Recall that the prior reported results obtained for the Vertical chamber were nominal at best, showing only a slight reduction in the arc rate after 5 heating cycles at the lower bias potentials and virtually no changes at high potential biases. It was concluded that the vertical chamber was unable to remove enough water vapor from the chamber to adequately test the arcing criterion. Because the cryo-pumped Teney chamber has a ten times better pumping speed, (40,000 liters per sec compared to 4,000 liters per sec for the diffusion pumped vertical chamber), a decision was made to retest that experiment in both the Teney and Vertical vacuum chambers. A comparison of the various data is presented with encouraging results.

  10. Simulating the thermal operating conditions in the thermal wells of ground-source heat-pump heat supply systems. Part I: Porous moisture freezing processes in soil

    Science.gov (United States)

    Vasilyev, G. P.; Peskov, N. V.; Lichman, V. A.; Gornov, V. F.; Kolesova, M. V.

    2015-08-01

    The mathematical models laid down in the new blocks of the INSOLAR.GSHP.12 software system simulating unsteady operating conditions of ground-source heat-pump (GSHP) heat supply systems are presented. The new model blocks take into account the effect the freezing of porous moisture in soil has on the GSHP system performance efficiency. Illustration is given to the need of taking into account the porous moisture freezing/thawing processes in soil, and the results from investigations devoted to the opening possibilities of constructing adaptive GSHP systems with controlled intensity of heat transfer in the soil-thermal well system are presented. The development of software simulating the porous moisture phase state variation processes in soil was preceded by development of mathematical equations representing the thermal conditions of soil body involving porous moisture freezing/thawing processes. A description of these equations is also given in the article. In constructing the mathematical model, the notion "effective thermal conductivity" of soil was introduced for taking into account the latent heat of phase transition that releases during the freezing of moisture. The above-mentioned effective thermal conductivity of soil involves two components: the soil thermal conductivity coefficient itself and an additional term modifying the thermal conductivity value for taking into account the influence of phase transition. For quantitatively evaluating the soil effective thermal conductivity component that takes into account the influence of phase transition, the soil freezing zone radius around the thermal well was determined. The obtained analytic solutions have been implemented in the form of computer program blocks, after which a "numerical experiment" was carried out for estimating the effect the porous moisture freezing/thawing processes have on the soil thermal conditions. It was demonstrated during that experiment that the soil thermal conductivities determined

  11. Development and Experimental Validation of a TRNSYS Dynamic Tool for Design and Energy Optimization of Ground Source Heat Pump Systems

    Directory of Open Access Journals (Sweden)

    Félix Ruiz-Calvo

    2017-09-01

    Full Text Available Ground source heat pump (GSHP systems stand for an efficient technology for renewable heating and cooling in buildings. To optimize not only the design but also the operation of the system, a complete dynamic model becomes a highly useful tool, since it allows testing any design modifications and different optimization strategies without actually implementing them at the experimental facility. Usually, this type of systems presents strong dynamic operating conditions. Therefore, the model should be able to predict not only the steady-state behavior of the system but also the short-term response. This paper presents a complete GSHP system model based on an experimental facility, located at Universitat Politècnica de València. The installation was constructed in the framework of a European collaborative project with title GeoCool. The model, developed in TRNSYS, has been validated against experimental data, and it accurately predicts both the short- and long-term behavior of the system.

  12. The contribution of geology and groundwater studies to city-scale ground heat network strategies: A case study from Cardiff, UK

    Science.gov (United States)

    Boon, David; Farr, Gareth; Patton, Ashley; Kendall, Rhian; James, Laura; Abesser, Corinna; Busby, Jonathan; Schofield, David; White, Debbie; Gooddy, Daren; James, David; Williams, Bernie; Tucker, David; Knowles, Steve; Harcombe, Gareth

    2016-04-01

    The development of integrated heat network strategies involving exploitation of the shallow subsurface requires knowledge of ground conditions at the feasibility stage, and throughout the life of the system. We describe an approach to the assessment of ground constraints and energy opportunities in data-rich urban areas. Geological and hydrogeological investigations have formed a core component of the strategy development for sustainable thermal use of the subsurface in Cardiff, UK. We present findings from a 12 month project titled 'Ground Heat Network at a City Scale', which was co-funded by NERC/BGS and the UK Government through the InnovateUK Energy Catalyst grant in 2015-16. The project examined the technical feasibility of extracting low grade waste heat from a shallow gravel aquifer using a cluster of open loop ground source heat pumps. Heat demand mapping was carried out separately. The ground condition assessment approach involved the following steps: (1) city-wide baseline groundwater temperature mapping in 2014 with seasonal monitoring for at least 12 months prior to heat pump installation (Patton et al 2015); (2) desk top and field-based investigation of the aquifer system to determine groundwater levels, likely flow directions, sustainable pumping yields, water chemistry, and boundary conditions; (3) creation of a 3D geological framework model with physical property testing and model attribution; (4) use steps 1-3 to develop conceptual ground models and production of maps and GIS data layers to support scenario planning, and initial heat network concept designs; (5) heat flow modelling in FEFLOW software to analyse sustainability and predict potential thermal breakthrough in higher risk areas; (6) installation of a shallow open loop GSHP research observatory with real-time monitoring of groundwater bodies to provide data for heat flow model validation and feedback for system control. In conclusion, early ground condition modelling and subsurface

  13. Characterisation of Seasonal Temperature Variation in a Shallow, Urban Aquifer: Implications for the Sustainable Development of Ground Source Heating Systems

    Science.gov (United States)

    Patton, Ashley M.; Farr, Gareth J.; Boon, David P.; James, David R.

    2017-04-01

    Groundwater thermally enhanced by the Urban Heat Island effect can be utilised by ground source heating systems (GSHSs). However, the near subsurface is subject to seasonal temperature variation reflected in shallow groundwater that can differ by several degrees throughout the year. To sustainably manage the near surface thermal resource an understanding of factors which control variation in groundwater temperature and how these are transmitted through the aquifer is needed. We show that even in relatively small urban areas (Cardiff, U.K., situated on a shallow gravel aquifer) the Zone of Seasonal Fluctuation (ZSF) can vary in depth by 8m. GSHSs are more efficient if they are sited below the ZSF, where temperatures are more stable. In Spring 2014, 48 groundwater monitoring boreholes were profiled at a 1m resolution to measure groundwater temperature across Cardiff. These were reprofiled that Autumn and compared to the Spring temperatures, defining the ZSF. The average depth to the base of the ZSF was 9.5mbgl but ranged from 7.1-15.5mbgl. The amplitude of the differences between Spring and Autumn temperatures also varied. To better understand the high spatial variability 60 boreholes were instrumented with in situ temperature loggers, recording at half-hourly intervals. The first year's data revealed the amplitudes of temperature variation within boreholes with loggers at similar depths were not always consistent. It was also noted that lag times between air temperature and groundwater temperature were not uniform across the sites. The data also showed that where gravels occurred at shallower depths the ZSF tended to be shallower and lag times shorter. The wide spatial variability of the ZSF may be partially explained by differing landuse. Those boreholes in open, grassed areas showed a deeper ZSF than those in built-up areas but built-up areas generally showed the greatest variation between Spring and Autumn temperature profiles, suggesting heat loss from buildings

  14. New-Measurement Techniques to Diagnose Charged Dust and Plasma Layers in the Near-Earth Space Environment Using Ground-Based Ionospheric Heating Facilities

    OpenAIRE

    Mahmoudian, Alireza

    2013-01-01

    Recently, experimental observations have shown that radar echoes from the irregularitysource region associated with mesospheric dusty space plasmas may be modulated by radio wave heating with ground-based ionospheric heating facilities. These experiments show great promise as a diagnostic for the associated dusty plasma in the Near-Earth Space Environment which is believed to have links to global change. This provides an alternative to more complicated and costly space-based observational app...

  15. Building ground analyses and expert opinions in district heating pipeline construction. Geotechnical investigations according to DIN 4020; Baugrunduntersuchungen und Baugrundgutachten im Fernwaermeleitungsbau. Geotechnische Untersuchungen nach DIN 4020

    Energy Technology Data Exchange (ETDEWEB)

    Weidlich, Ingo [AGFW Energieeffizienzverband fuer Waerme, Kaelte und KWK e.V., Frankfurt am Main (Germany)

    2010-12-15

    During construction of district heating pipelines, the specifications of the pertinent technical rules must be observed in order to ensure regular construction and to prevent damage. In principle, analyses of the building ground are required depending on the construction project and the pertinent DIN standards. The author lists the standards that are relevant for geotechnical operation, makes an evaluation of these standards, and explains their relevance in the construction of district heating pipelines. (orig.)

  16. Planar, monolithically integrated coil

    NARCIS (Netherlands)

    Roozeboom, F.; Reefman, D.; Klootwijk, J.H.; Tiemeijer, L.F.; Ruigrok, J.

    2013-01-01

    The present invention provides a means to integrate planar coils on silicon, while providing a high inductance. This high inductance is achieved through a special back- and front sided shielding of a material. In many applications, high-value inductors are a necessity. In particular, this holds for

  17. An orientable search coil

    Science.gov (United States)

    Holt, P. J.; Poblocki, M.

    2017-01-01

    We provide a design for a low cost orientable search coil that can be used to investigate the variation of magnetic flux with angle. This experiment is one of the required practical activities in the current A level physics specification for the AQA examination board in the UK. We demonstrate its performance and suggest other suitable investigations that can be undertaken.

  18. Helical coil thermal hydraulic model

    Science.gov (United States)

    Caramello, M.; Bertani, C.; De Salve, M.; Panella, B.

    2014-11-01

    A model has been developed in Matlab environment for the thermal hydraulic analysis of helical coil and shell steam generators. The model considers the internal flow inside one helix and its associated control volume of water on the external side, both characterized by their inlet thermodynamic conditions and the characteristic geometry data. The model evaluates the behaviour of the thermal-hydraulic parameters of the two fluids, such as temperature, pressure, heat transfer coefficients, flow quality, void fraction and heat flux. The evaluation of the heat transfer coefficients as well as the pressure drops has been performed by means of the most validated literature correlations. The model has been applied to one of the steam generators of the IRIS modular reactor and a comparison has been performed with the RELAP5/Mod.3.3 code applied to an inclined straight pipe that has the same length and the same elevation change between inlet and outlet of the real helix. The predictions of the developed model and RELAP5/Mod.3.3 code are in fairly good agreement before the dryout region, while the dryout front inside the helical pipes is predicted at a lower distance from inlet by the model.

  19. A system for vertical profile measurements of sensible heat and chemical concentrations near the ground surface

    Energy Technology Data Exchange (ETDEWEB)

    Hyppoenen, M.; Walden, J.A.

    1996-12-31

    The design, construction and measurements of a computer controlled system applicable to flux measurements of a scalar quantity by the gradient technique are described. Accuracy requirements for the measured variables which are used for flux calculations are considered, together with some practical aspects concerning data storage and control. The construction includes the hardware and the data acquisition, sample intake, and temperature measurement systems. The measurements comprise laboratory tests of the temperature probes and the hardware as well as field tests over wheat and grass land for temperature and wind speed and ozone (O{sub 3}), carbon dioxide (CO{sub 2}) and nitrous oxide (N{sub 2}O) concentration profiles. The hardware takes care of most of the operation and only the necessary part is done by the software. The data acquisition system is flexible, accepting the input of either digital and/or analog signals. It also controls the whole system, storing all the data in a single data file. The sample intake unit is designed to take continuous samples in to the monitors as well as grab samples into the canisters. Samples can be selected from one to four levels with no dead volumes in the sampling tubes. The temperature measurement system is constructed using a pair of temperature probes, Pt-100, which are connected to the same signal processing card, in order to remove the offset of the electronic components as well as the bias associated with single probes. This ensures the accuracy of the probes down to 0.005 deg C. According to the field measurements, the relative error limits for the sensible heat fluxes varied from 7 to 20 % in an unstable atmospheric situation. For the ozone flux, the error limits varied from 20 to 100 %, indicating a much poorer accuracy of the monitor compared to the temperature probes. (orig.) 16 refs.

  20. 地源热泵系统冷凝热回收在降温除湿工况的研究%Cooling and Dehumidifying Conditions of the Condensation Heat Recovery of Ground-Source Heat Pump Systems

    Institute of Scientific and Technical Information of China (English)

    江盼; 陈剑波; 陈希望

    2015-01-01

    Considering the reheat process in cooling and dehumidifying conditions during the transitional season causes problems that cold and hot counteraction does not meet the energy requirements, and heat accumulation exists generally in the ground -source heat pump system in cold and wet load dominated area. The thesis proposes a ground-source heat pump system which can recover the condensation heat to reheat air. This system can not only reduce the emission of heat to the soil to relieve heat accumulation of the soil and improve the coefficient of performance, but also effectively use the waste heat from the water of the heat of condensation. Through simulation and experimental analysis, the advantages and feasibility can be drawn with a condensing heat recovery ground source heat pump system.%综合考虑在过渡季节降温除湿工况的再热过程会造成冷热抵消引起的不符合节能要求的问题和地源热泵系统在冷(湿)负荷为主的地区普遍存在的热堆积问题,提出了一种利用冷凝热再热空气的地源热泵系统。此系统既能减少向土壤侧排放的热量,缓解土壤的热堆积,并提高机组的运行效率,同时,又有效地利用了冷凝排放的热量。通过模拟计算和实验分析,得出带有冷凝热回收的地源热泵系统的可行性和应用优势。

  1. 地源热泵技术的概念及应用%The Concept and Application of Ground Source Heat Pump Technology

    Institute of Scientific and Technical Information of China (English)

    程应欣

    2014-01-01

    Ground source heat pump is a new air conditioning heating method which features high efficiency, energy saving and environmental protection. The application of ground source heat pump technology facilitates the solvement of two major problems: energy crisis and environmental pol ution and thus brings opportunity of sustainable development of China. The development of ground source heat pump in China has a vast prospect. This paper starts with the origin of ground source heat pump, and then combines with analysis of its development both in China and abroad so as to put forward opinions and sug-gestions for the development of ground source heat pump technology in China.%地源热泵是一种集高效、节能、环保、有利于可持续发展于一身的新型空调采暖方式,地源热泵技术的应用有利于解决能源危机和环境污染这两个困扰中国发展的重大问题,进而为中国的可持续发展带来了契机,地源热泵在中国有广阔的发展前景。从地源热泵的由来入手,结合国内外地源热泵发展情况的分析,得出地源热泵的特点,从而为中国发展地源热泵技术提出了意见和建议。

  2. Oval gradient coils for an open magnetic resonance imaging system with a vertical magnetic field

    Science.gov (United States)

    Matsuzawa, Koki; Abe, Mitsushi; Kose, Katsumi; Terada, Yasuhiko

    2017-05-01

    Existing open magnetic resonance imaging (MRI) systems use biplanar gradient coils for the spatial encoding of signals. We propose using novel oval gradient coils for an open vertical-field MRI. We designed oval gradients for a 0.3 T open MRI system and showed that such a system could outperform a traditional biplanar gradient system while maintaining adequate gradient homogeneity and subject accessibility. Such oval gradient coils would exhibit high efficiency, low inductance and resistance, and high switching capability. Although the designed oval Y and Z coils showed more heat dissipation and less cooling capability than biplanar coils with the same gap, they showed an efficient heat-dissipation path to the surrounding air, which would alleviate the heat problem. The performance of the designed oval-coil system was demonstrated experimentally by imaging a human hand.

  3. Characteristic of gas production of over-ground household thermostatic biogas digester heated by solar energy%地上式户用太阳能恒温沼气池产气性能

    Institute of Scientific and Technical Information of China (English)

    李金平; 单少雄; 董缇

    2015-01-01

    In order to solve the problems of unstable gas production, the low biogas production rate, and the zero-gas production in winter existing in the traditional biogas digester with a brick-concrete structure, an over-ground household thermostatic biogas digester heated by solar energy was developed and constructed. The system consists of a glass evacuated tube collector with the collector area of 2.96 m2, a 2 m×2 m×3.2 m insulating chamber, a 3 m3 plastic biogas digester, a 3 m3 reservoir bag, an automatic temperature controller, a heating coil, and some other small parts. The energy collected by the solar collector is stored in water and the hot water is circulated in the heating coil by the circulating pump. The pump is directly controlled by the automatic temperature controller. The automatic temperature controller can be set an initial value. If the fermentation temperature is below the set point, the automatic control system will work to let the circulating pump start, and then the hot water will transfer heat to the biogas digester through the heating coil to keep the fermentation temperature at the set point. And similarly, the circulating pump will be shut down, controlled by the automatic control system, if the fermentation temperature reaches or exceeds the set value. Experimental study on the gas production of the system in winter was carried out. The fermentation material consisted of 0.5 m3 pig manure, 0.5 m3 inoculum, and 1 m3 water. During the experiment, the temperature data was recorded by the Agilent data acquisition instrument, the daily gas yield was measured by the gas meter, the gas content is measured by the portable gas analyzer, and the pH value was recorded by the portable pH meter, which was done at 17:00 every day. In order to ensure the uniformity of heat transfer and material liquid in the digester, stirring work was done daily. By analyzing the data collected, we could conclude that the solar collector can ensure the digester

  4. Antimicrobial activity of plant compounds against Salmonella Typhimurium DT104 in ground pork and the influence of heat and storage on the activity

    Science.gov (United States)

    The objectives of this study were to investigate the influence of heat (70oC for 5 min) and cold-storage (4oC up to 7 days) on the effectiveness of oregano and cinnamon essential oils and powdered olive and apple extracts against Salmonella Typhimurium DT104 in ground pork and to evaluate the activi...

  5. Effects of heat stress and probiotic supplementation on protein functionality and oxidative stability of ground chicken leg meat during display storage

    Science.gov (United States)

    The objective of this study was to evaluate effects of heat stress and probiotic supplementation on protein functionality and oxidative stability of ground chicken leg meat during display storage. Two hundred and forty 1-day-old male chicks (5 bird per pen) were randomly subjected to four treatments...

  6. Effects of heat stress and probiotic supplementation on protein functionality and oxidative stability of ground chicken leg meat during display storage.

    Science.gov (United States)

    Kim, Hyun-Wook; Kim, Ji-Han; Yan, Feifei; Cheng, Heng-Wei; Brad Kim, Yuan H

    2017-05-11

    The present study aimed to evaluate the effects of heat stress and probiotic supplementation on protein functionality and oxidative stability of ground chicken leg during display storage. Two hundred and forty, 1-day-old male chicks (5 birds per pen) were subjected to four treatments in a 2 (thermoneutral condition at 21 °C and cyclic heat stress at 32-21-32 °C for 10 h day(-1) ) × 2 (regular diet with 0 or 0.25 g kg(-1) Bacillus subtilis) factorial design. Chickens were harvested at day 46, and pairs of whole legs were collected at 1 day postmortem. The chicken legs were deboned, ground, tray-packaged with oxygen-permeable film, and displayed for 3 days. Heat stress and probiotic supplementation had no impact on pH, water-holding capacity, color, protein functionality, lipid lipolysis and lipid/protein oxidation stability (P > 0.05). Display storage increased the pH and lipid oxidation of ground chicken legs (P heat stress and probiotic supplementation had no practical adverse impact on protein functionality and oxidative stability of ground chicken leg meat. © 2017 Society of Chemical Industry. © 2017 Society of Chemical Industry.

  7. A Modified Alderman-Grant Coil makes possible an efficient cross-coil probe for high field solid-state NMR of lossy biological samples

    Science.gov (United States)

    Grant, Christopher V.; Yang, Yuan; Glibowicka, Mira; Wu, Chin H.; Park, Sang Ho; Deber, Charles M.; Opella, Stanley J.

    2009-11-01

    The design, construction, and performance of a cross-coil double-resonance probe for solid-state NMR experiments on lossy biological samples at high magnetic fields are described. The outer coil is a Modified Alderman-Grant Coil (MAGC) tuned to the 1H frequency. The inner coil consists of a multi-turn solenoid coil that produces a B 1 field orthogonal to that of the outer coil. This results in a compact nested cross-coil pair with the inner solenoid coil tuned to the low frequency detection channel. This design has several advantages over multiple-tuned solenoid coil probes, since RF heating from the 1H channel is substantially reduced, it can be tuned for samples with a wide range of dielectric constants, and the simplified circuit design and high inductance inner coil provides excellent sensitivity. The utility of this probe is demonstrated on two electrically lossy samples of membrane proteins in phospholipid bilayers (bicelles) that are particularly difficult for conventional NMR probes. The 72-residue polypeptide embedding the transmembrane helices 3 and 4 of the Cystic Fibrosis Transmembrane Conductance Regulator (CFTR) (residues 194-241) requires a high salt concentration in order to be successfully reconstituted in phospholipid bicelles. A second application is to paramagnetic relaxation enhancement applied to the membrane-bound form of Pf1 coat protein in phospholipid bicelles where the resistance to sample heating enables high duty cycle solid-state NMR experiments to be performed.

  8. Properties of cryocooler-cooled superconductive pulse coil (1); Chokureishiki chodendo parusu koiru no tokusei hyoka (1)

    Energy Technology Data Exchange (ETDEWEB)

    Hae, T.; Kajikawa, K.; Iwakuma, M.; Funaki, K. [Kyushu Univ., Fukuoka (Japan); Hayashi, H.; Tsutsumi, K. [Kyushu Electric Power Co., Inc., Fukuoka (Japan); Tomioka, A.; Konno, M.; Nose, S. [Fuji Electric Corp., Tokyo (Japan)

    1999-11-10

    We manufactured the pulse coil of refrigerating machine direct cooling system using oxide superconducting wire rod, and they succeeded in triangular wave continuous running of 1T and 1Hz. It aimed at future further scale-up using this pulse coil this time, and the relationship between heat quantity and coil temperature rise in the operation was evaluated. (NEDO)

  9. 暖通空调设计中地源热泵的运用%The Use of Ground Source Heat Pump in HVAC Design

    Institute of Scientific and Technical Information of China (English)

    杜志宏; 陈昀; 米泉龄; 尤炜

    2011-01-01

    地源热泵的能量来源是由各种资源所提供,主要包括了地源、水源、空气源等,当这些能量集中到一起之后能够与建筑物供冷供热的热泵技术想结合,由此处理成为城市供冷供暖的最佳方式.本文结合工程案例针对暖通空调设计中地源热泵问题进行了多方面的研究.%The energy sources of ground source heat pump are provided by various resources, including ground source, water source, air source, and others. When these energy is concentrated together, it can combine with cooling and heating heat pump technology of building, which became the best way to deal with urban cooling and heating. In this paper, the problems of ground source heat pump in design for HVAC are analyzed from many aspects with the projects.

  10. 地源热泵的应用与技术性分析%Application and Technical Analysis of Ground Source Heat Pumps

    Institute of Scientific and Technical Information of China (English)

    刘孝刚

    2015-01-01

    Ground source heat pump is a shallow underground resources of both cooling and heating functions heat pump system. The unit has the advantages of easy maintenance, energy saving, no secondary environment pollution. Taking a ground source heat pump works as a technical analysis examples, the number of options the air conditioning units were analyzed and compared. The development prospects of ground-source heat pump system were discussed.%地源热泵是一种利用地下浅层资源兼有制冷制热功能的热泵空调系统,其机组维护方便、节能环保,对环境没有二次污染。文中通过对地源热泵工程实例的技术性分析,对多个方案的空调机组进行了分析比较,对地源热泵系统的发展前景进行了展望。

  11. Building America Case Study: Ground Source Heat Pump Research, TaC Studios Residence, Atlanta, Georigia (Fact Sheet)

    Energy Technology Data Exchange (ETDEWEB)

    2014-09-01

    As part of the NAHB Research Center Industry Partnership, Southface partnered with TaC Studios, an Atlanta based architecture firm specializing in residential and light commercial design, on the construction of a new test home in Atlanta, GA in the mixed-humid climate. This home serves as a residence and home office for the firm's owners, as well as a demonstration of their design approach to potential and current clients. Southface believes the home demonstrates current best practices for the mixed-humid climate, including a building envelope featuring advanced air sealing details and low density spray foam insulation, glazing that exceeds ENERGY STAR requirements, and a high performance heating and cooling system. Construction quality and execution was a high priority for TaC Studios and was ensured by a third party review process. Post construction testing showed that the project met stated goals for envelope performance, an air infiltration rate of 2.15 ACH50. The homeowner's wished to further validate whole house energy savings through the project's involvement with Building America and this long-term monitoring effort. As a Building America test home, this home was evaluated to detail whole house energy use, end use loads, and the efficiency and operation of the ground source heat pump and associated systems. Given that the home includes many non-typical end use loads including a home office, pool, landscape water feature, and other luxury features not accounted for in Building America modeling tools, these end uses were separately monitored to determine their impact on overall energy consumption.

  12. 地源热泵单U型地埋管换热器的传热模拟分析%Simulation Analysis of Single U-tube Underground Heat Exchanger for Ground Source Heat Pump

    Institute of Scientific and Technical Information of China (English)

    张晓伟; 曹红奋

    2016-01-01

    Aunderground heat exchanger heat transfer model for single U -tube underground heat exchanger was es-tablished based on the heat transfer characteristics of the ground source heat pump .The influences of the different in-let water temperature , different flow rate and different backfill materials on the single U -tube underground heat ex-changer capability were simulation analysis .The results may provide guidance for the same type of ground source heat pump.%本文针对地源热泵单U型地埋管换热器的换热特性,建立了地埋管换热器的传热模型,模拟分析了不同的进口水温、不同的流速以及不同的回填材料对单U型地埋管换热器换热能力的影响,研究结果可为同类型的地源热泵项目提供参考和借鉴。

  13. Sideband cooling an ion to the quantum ground state in a Penning trap with very low heating rate

    CERN Document Server

    Goodwin, J F; Thompson, R C; Segal, D M

    2014-01-01

    We report the laser cooling of a single $^{40}\\text{Ca}^+$ ion in a Penning trap to the motional ground state in one dimension. Cooling is performed in the strong binding limit on the 729-nm electric quadrupole $S_{1/2}\\leftrightarrow D_{5/2}$ transition, broadened by a quench laser coupling the $D_{5/2}$ and $P_{3/2}$ levels. We find the final phonon number to be $\\bar{n}=0.012\\pm0.009$. We measure the heating rate of the trap to be exceptionally low with $\\dot{\\bar{n}}=0.08\\pm 0.12~\\textrm{s}^{-1}$ and a scaled spectral noise density of $\\omega S_{\\omega}<1.6\\times10^{-10}~\\textrm{V}^{2}\\textrm{m}^{-2}\\textrm{Hz}^{-1}\\textrm{s}^{-1}$, which is consistent with the large ion-electrode distance. We perform Rabi oscillations on the sideband-cooled ion and observe a coherence time of $0.7\\pm 0.1~\\textrm{ms}$, noting that the practical performance is limited primarily by the intensity noise of the probe laser.

  14. 太阳能-地源热泵与热网互补供暖系统的仿真性能研究%Research on the Simulation of Solar-Ground Source Heat Pump and Heating Network Complementary Heating System

    Institute of Scientific and Technical Information of China (English)

    郝红; 付晓晨; 冯国会; 张剑

    2014-01-01

    以沈阳地区典型民用住宅建筑为例,对太阳能-地源热泵与热网互补供暖系统进行仿真研究。利用TRNSYS软件,建立太阳能-地源热泵与热网互补供暖系统仿真模型和地源热泵与热网互补供暖系统仿真模型,对2种系统的蒸发器进出水温度、热泵机组COP,及热网加热量进行对比分析,结果表明:太阳能-地源热泵与热网互补供暖系统相比地源热泵与热网互补供暖系统的平均出水温度提高了50.41%;平均进水温度提高了53.08%;平均COP由3.167增加到4.65;热网运行时间由1540h增加到2032h;热网供暖季的平均换热量由114566.62kJ/h减少到101257.27kJ/h。%Taking the typical building in severe cold region as an example,the simulation of solar-ground source heat pump and heating network complementary heating system was studied. By using TRNSYS software, build a solar-ground source heat pump and heating network complementary heating system simulation model and ground source heat pump and heating network comple-mentary heating system simulation model, then make the contrast analysis of the in and out of the water temperature of evapora-tor, the COP of heat pump units, and the heating capacity of heat supply network in the two systems. The results show that com-pare ground source heat pump and heating network complementary heating system with solar-ground source heat pump and heating network complementary heating system, the average inlet water temperature increased by 50. 41%,the average outlet water tem-perature increased by 53. 08%;the average COP increased from 3. 167 to 3. 167; heat supply network running time increased from 1540 h to 2032 h, the average heat transfer of heat supply network heating season from 114566. 62kJ/h is reduced to 101257. 27kJ/h .

  15. Studies of a thermal energy storage unit with ice on coils; Ice on coil gata kori chikunetsuso no kenkyu

    Energy Technology Data Exchange (ETDEWEB)

    Ito, S.; Miura, N. [Kanagawa Institute of Technology, Kanagawa (Japan)

    1996-10-27

    Study was made of an ice-on-coil heat storage tank for power load levelling. Prior to the prediction of performance of the system as a whole, the performance of the heat storage tank itself needs to be predicted. A brine (35.9% water solution of ethylene glycol) cooled by a refrigerating machine was poured from the upper end of the piping in the heat storage tank (consisting of 19 spiral pipes or coils arranged in parallel in the vertical direction) for the collection of ice around the coils. Ice grew thicker with the passage of time but there was no remarkable decrease in the transfer of heat because there was an increase in the area of contact between ice and water, and the brine exit temperature remained constant over a prolonged period of time. There was a close agreement between experiment results and theoretical conclusions throughout the heat accumulation process, including changes with time in the thickness of ice on the coils, all pointing to the appropriateness of this analytical effort. To melt the ice, water was poured into the tank top at a predetermined rate. Water chilly at 2-4{degree}C was recovered at the tank bottom, stable in the amount produced. As for the use of spiral pipes for making ice, the laminar heat transfer rate in such pipes are supposed to be more than two times higher than that in straight pipes, and this was quite effective in accelerating heat transfer. 7 refs., 11 figs.

  16. Application on Ground Source Heat Pump in Urumqi%地源热泵在乌鲁木齐的应用研究

    Institute of Scientific and Technical Information of China (English)

    郭亮

    2016-01-01

    地源热泵技术就是充分利用地热能的一种可再生能源的高效、节能、环保型工程系统。阐述地源热泵技术的工作原理,并以新疆电力科学研究院地源热泵工程系统为例,通过运用对季节系统能效比和能源利用系数的计算,分析了地源热泵系统的节能优势;通过与传统燃煤锅炉对环境影响的对比,分析了地源热泵在环境保护方面的优势。通过分析得出,地源热泵系统在主要靠燃煤锅炉供热的乌鲁木齐推广很有意义,可以替代传统的燃煤锅炉,减少原煤的使用,减少污染物的排放,对解决乌鲁木齐冬季空气污染起到很好的作用。%Ground source heat pump technology is a kind of high efficiency, energy saving and environmental protec-tion engineering system of renewable en-ergy sources by the use of geothermal energy. In the study, operating principle of ground source heat pump technology was expounded, ground source heat pump engineering system of Xinjiang electric power research institute was tak-en as an example. Energy-saving advan-tages of ground-source heat pump system was analyzed by the calculation of ener-gy ratio and seasonal system energy effi-ciency ratio. The results showed that there was an important significance on the promotion of ground-source heat pump system in Urumqi. At present, the major heat addition system of Urumqi was still coal-fired boiler, the application of ground-source heat pump system could reduce the use of raw coal and the emissions of pollutants, which had a pos-itive influence on the solution of air pol-lution in winter in Urumqi.

  17. Progress of the ITER Correction Coils in China

    CERN Document Server

    Wei, J; Han, S; Yu, X; Du, S; Li, C; Fang, C; Wang, L; Zheng, W; Liu, L; Wen, J; Li, H; Libeyre, P; Dolgetta, N; Cormany, C; Sgobba, S

    2014-01-01

    The ITER Correction Coils (CC) include three sets of six coils each, distributed symmetrically around the tokamak to correct error fields. Each pair of coils, located on opposite sides of the tokamak, is series connected with polarity to produce asymmetric fields. The manufacturing of these superconducting coils is undergoing qualification of the main fabrication processes: winding into multiple pancakes, welding helium inlet/outlet on the conductor jacket, turn and ground insulation, vacuum pressure impregnation, inserting into an austenitic stainless steel case, enclosure welding, and assembling the terminal service box. It has been proceeding by an intense phase of R\\&D, trials tests, and final adjustment of the tooling. This paper mainly describes the progress in ASIPP for the CC manufacturing process before and on qualification phase and the status of corresponding equipment which are ordered or designed for each process. Some test results for the key component and procedure are also presented.

  18. Analysis on the construction technology of heat exchanger of Ground-Source Heat Pump(GSHP) system%土壤源热泵换热器施工工艺分析

    Institute of Scientific and Technical Information of China (English)

    王祁生

    2011-01-01

    以实际工程为背景,研究了土壤源热泵技术的工作原理,详细阐述了土壤源热泵换热器施工工艺和操作要点以及注意事项,旨在推广土壤源热泵技术的应用,实现节能环保目标。%Taking actual engineering as the background,it studies the working principle of Ground-Source Heat Pump technology,describes the cosntruciton technology and operation points and attentions of heat exchanger of Ground-Source Heat Pump,with a view to promot

  19. Development of design software on ground heat exchanger based on coupling method%基于耦合法的地埋管换热器设计软件的研发

    Institute of Scientific and Technical Information of China (English)

    陈胜朋; 沈意成; 陈振乾; 张辉

    2011-01-01

    由于地埋管换热器与土壤换热的复杂性,其设计一直是地埋管地源热泵技术的难点.介绍了一种基于地埋管地源热泵动态模型的设计方法,综合考虑了地下土壤热物性、热泵机组的动态特性及建筑的动态负荷模型等,开发出了具有操作简便、交互界面的软件,为地埋管地源热泵的设计提供技术支持.%Complexity of heat transfer between ground heat exchanger and soil results in technical difficulties in design of the ground heat exchanger ground-source heat pump. Presents a new design method based on dynamic model of ground heat exchanger ground-source heat pump in which the influence of the soil thermal properties, the heat pump unit's dynamic property and building dynamic load model are considered. Develops a user-friendly software interface, providing support for the ground heat exchanger ground-source heat pump design.

  20. 地源热泵的研究与应用现状%Research and Application Status of Ground Source Heat Pump

    Institute of Scientific and Technical Information of China (English)

    武曈; 刘钰莹; 董喆; 方莹; 刘益才

    2014-01-01

    The paper starts with a brief introduction to the classification and working principle of ground source heat pump (GSHP) in three aspects of ground coupled heat pump system, ground water source heat pump system, surface water source heat pump system, and a brief overview of these three ground source heat pump systems is illustrated on the basis of the features and quality. Based on the research and application at home and abroad, new trends and new research progress of ground source heat pump in twenty-first century are mainly analyzed, i. e. using modern means to analysis and improve the water carrying capacity and the performance of the pump system. At the same time, the concise examples about the combination of the new technology and the original technology of heat pump are listed in the paper, such as the summary of solar, ice storage and waste heat utilization. A conclusion can be drawn that notable advantages of GSHP with respects to energy saving and environment protection must lead to a wide application prospect of GSHP system in China.%本文从土壤耦合热泵系统、地下水地源热泵系统、地表水地源热泵系统三个方面,介绍了地源热泵的分类及工作原理,并在分类的基础上对三大地源热泵系统进行了简要的概述,说明其特点和优劣。在综合国内外研究应用的基础上,重点总结分析了21世纪地源热泵的研究进展及新研究趋势--针对水体承载能力、热泵系统的效能等利用现代手段进行分析和提高。同时,本文对新技术与热泵原有技术的结合进行了简明例举,列举出与太阳能、冰蓄冷、余热利用相关的概要。通过本文表明地源热泵在节能环保方面的显著优势,也证明其在我国拥有广泛的应用前景。

  1. Feasibility Study: Ductless Hydronic Distribution Systems with Fan Coil Delivery

    Energy Technology Data Exchange (ETDEWEB)

    Springer, D.; Dakin, B.; Backman, C.

    2012-07-01

    The primary objectives of this study are to estimate potential energy savings relative to conventional ducted air distribution, and to identify equipment requirements, costs, and barriers with a focus on ductless hydronic delivery systems that utilize water-to-air terminal units in each zone. Results indicate that annual heating and cooling energy use can be reduced by up to 27% assuming replacement of the conventional 13 SEER heat pump and coil with a similarly rated air-to-water heat pump.

  2. Output beam analysis of high power COIL

    Institute of Scientific and Technical Information of China (English)

    Deli Yu(于德利); Fengting Sang(桑凤亭); Yuqi Jin(金玉奇); Yizhu Sun(孙以珠)

    2003-01-01

    As the output power of a chemical oxygen iodine laser (COIL) increases, the output laser beam instabilityappears as the far-field beam spot drift and deformation for the large Fresnel number unstable resonator.In order to interpret this phenomenon, an output beam mode simulation code was developed with the fastFourier transform method. The calculation results show that the presence of the nonuniform gain in COILproduces a skewed output intensity distribution, which causes the mirror tilt and bulge due to the thermalexpansion. With the output power of COIL increases, the mirror surfaces, especially the back surface ofthe scraper mirror, absorb more and more heat, which causes the drift and deformation of far field beamspot seriously. The initial misalignment direction is an important factor for the far field beam spot driftingand deformation.

  3. Review of the ATLAS B0 model coil test program

    CERN Document Server

    Dolgetta, N; Acerbi, E; Berriaud, C; Boxman, H; Broggi, F; Cataneo, F; Daël, A; Delruelle, N; Dudarev, A; Foussat, A; Haug, F; ten Kate, H H J; Mayri, C; Paccalini, A; Pengo, R; Rivoltella, G; Sbrissa, E

    2004-01-01

    The ATLAS B0 model coil has been extensively tested, reproducing the operational conditions of the final ATLAS Barrel Toroid coils. Two test campaigns have taken place on B0, at the CERN facility where the individual BT coils are about to be tested. The first campaign aimed to test the cool-down, warm-up phases and to commission the coil up to its nominal current of 20.5 kA, reproducing Lorentz forces similar to the ones on the BT coil. The second campaign aimed to evaluate the margins above the nominal conditions. The B0 was tested up to 24 kA and specific tests were performed to assess: the coil temperature margin with respect to the design value, the performance of the double pancake internal joints, static and dynamic heat loads, behavior of the coil under quench conditions. The paper reviews the overall test program with emphasis on second campaign results not covered before. 10 Refs.

  4. 地源热泵系统节能潜力分析%Analysis of energy saving potential of ground source heat pump system

    Institute of Scientific and Technical Information of China (English)

    李新付

    2015-01-01

    在三星级绿色公共建筑中采用地源热泵系统供冷供热,可以在建筑全寿命期内最大限度地节约能源、保护环境减少污染。本文通过对安阳市民之家(三星绿建)采用的地下室地源热泵进行定性定量分析,阐明地源热泵系统的巨大节能空间。%The use of ground source heat pump system for cold heating in the three star green building, can save energy and protect the environment to reduce pollution in the whole life period. In this paper, a qualitative and quantitative analysis of the ground source heat pump is carried out, and the great energy saving space of the ground source heat pump system is expounded.

  5. Fabrication and Analysis of 150 mm Aperture Nb3Sn LARP MQXF Coils

    CERN Document Server

    Holik, E F; Anerella, M; Bossert, R; Cavanna, E; Cheng, D; Dietderich, D R; Ferracin, P; Ghosh, A K; Izquierdo Bermudez, S; Krave, S; Nobrega, A; Perez, J C; Pong, I; Rochepault; Sabbi, G L; Schmalzle, J; Yu, M

    2016-01-01

    The US LHC Accelerator Research Program (LARP) and CERN are combining efforts for the HiLumi-LHC upgrade to design and fabricate 150 mm aperture, interaction region quadrupoles with a nominal gradient of 130 T/m using Nb3Sn. To successfully produce the necessary long MQXF triplets, the HiLumi-LHC collaboration is systematically reducing risk and design modification by heavily relying upon the experience gained from the successful 120 mm aperture LARP HQ program. First generation MQXF short (MQXFS) coils were predominately a scaling up of the HQ quadrupole design allowing comparable cable expansion during Nb3Sn formation heat treatment and increased insulation fraction for electrical robustness. A total of 13 first generation MQXFS coils were fabricated between LARP and CERN. Systematic differences in coil size, coil alignment symmetry, and coil length contraction during heat treatment are observed and likely due to slight variances in tooling and insulation/cable systems. Analysis of coil cross sections indic...

  6. Nonazeotropic Heat Pump

    Science.gov (United States)

    Ealker, David H.; Deming, Glenn

    1991-01-01

    Heat pump collects heat from water circulating in heat-rejection loop, raises temperature of collected heat, and transfers collected heat to water in separate pipe. Includes sealed motor/compressor with cooling coils, evaporator, and condenser, all mounted in outer housing. Gradients of temperature in evaporator and condenser increase heat-transfer efficiency of vapor-compression cycle. Intended to recover relatively-low-temperature waste heat and use it to make hot water.

  7. Nonazeotropic Heat Pump

    Science.gov (United States)

    Ealker, David H.; Deming, Glenn

    1991-01-01

    Heat pump collects heat from water circulating in heat-rejection loop, raises temperature of collected heat, and transfers collected heat to water in separate pipe. Includes sealed motor/compressor with cooling coils, evaporator, and condenser, all mounted in outer housing. Gradients of temperature in evaporator and condenser increase heat-transfer efficiency of vapor-compression cycle. Intended to recover relatively-low-temperature waste heat and use it to make hot water.

  8. Characterization of coiled SMA actuators for humanoid robot

    Science.gov (United States)

    Potnuru, Akshay; Tadesse, Yonas

    2017-04-01

    In this paper, we present modeling and characterization of coiled SMA spring actuators that are fabricated by coiling cylindrical SMA wires on to a threaded screw mandrel and applying heat treatment. Here, we evaluate a theoretical model that describes the actuation behavior of SMA coiled springs based on the constitutive model of SMA. We have experimentally verified the developed theoretical model and analyzed various parameters with respect to temperature change during actuation. The model was coded in Simulink® and the effects of various parameters with respect to temperature change were investigated. Simulations were compared with experiments and good agreement was obtained. We also show, how the high tension winding of SMA on the mandrel help in better performance and understanding of the fabricated coiled SMAs.

  9. Introduction to COIL

    OpenAIRE

    Kane, David

    2008-01-01

    By reciprocal arrangement between WIT and the National College of Ireland, you are now able to access their collection directly - more than 100,000 items. This form of direct consortial borrowing has never been tried before in Ireland. Before you borrow your first book, you will have to set up a COIL account, which is straightforward. The items which you reserve online will be posted to us, for you to collect, at the front desk in the Luke Wadding library, afterwards. The Initiat...

  10. Triple Halo Coil: Development and Comparison with Other TMS Coils

    Science.gov (United States)

    Rastogi, Priyam; Hadimani, Ravi; Jiles, David

    Transcranial Magnetic Stimulation (TMS) is a non-invasive stimulation technique that can be used for the treatment of various neurological disorders such as Parkinson's Disease, PTSD, TBI and anxiety by regulating synaptic activity. TMS is FDA approved for the treatment of major depressive disorder. There is a critical need to develop deep TMS coils that can stimulate deeper regions of the brain without excessively stimulating the cortex in order to provide an alternative to surgical methods. We have developed a novel multi-coil configuration called ``Triple Halo Coil'' (THC) that can stimulate deep brain regions. Investigation of induced electric and magnetic field in these regions have been achieved by computer modelling. Comparison of the results due to THC configuration have been conducted with other TMS coils such as ``Halo Coil'', circular coil and ``Figure of Eight'' coil. There was an improvement of more than 15 times in the strength of magnetic field, induced by THC configuration at 10 cm below the vertex of the head when compared with the ``Figure of Eight'' coil alone. Carver Charitable Trust.

  11. Solar assisted heat pump on air collectors: A simulation tool

    Energy Technology Data Exchange (ETDEWEB)

    Karagiorgas, Michalis; Galatis, Kostas; Tsagouri, Manolis [Department of Mechanical Engineering Educators, ASPETE, N. Iraklio, GR 14121 (Greece); Tsoutsos, Theocharis [Environmental Engineering Dept., Technical University of Crete, Technical University Campus, GR 73100, Chania (Greece); Botzios-Valaskakis, Aristotelis [Centre for Renewable Energy Sources (CRES), 19th km Marathon Ave., GR 19001, Pikermi (Greece)

    2010-01-15

    The heating system of the bioclimatic building of the Greek National Centre for Renewable Energy Sources (CRES) comprises two heating plants: the first one includes an air source heat pump, Solar Air Collectors (SACs) and a heat distribution system (comprising a fan coil unit network); the second one is, mainly, a geothermal heat pump unit to cover the ground floor thermal needs. The SAC configuration as well as the fraction of the building heating load covered by the heating plant are assessed in two operation modes; the direct (hot air from the collectors is supplied directly to the heated space) and the indirect mode (warm air from the SAC or its mixture with ambient air is not supplied directly to the heated space but indirectly into the evaporator of the air source heat pump). The technique of the indirect mode of heating aims at maximizing the efficiency of the SAC, saving electrical power consumed by the compressor of the heat pump, and therefore, at optimizing the coefficient of performance (COP) of the heat pump due to the increased intake of ambient thermal energy by means of the SAC. Results are given for three research objectives: assessment of the heat pump efficiency whether in direct or indirect heating mode; Assessment of the overall heating plant efficiency on a daily or hourly basis; Assessment of the credibility of the suggested simulation model TSAGAIR by comparing its results with the TRNSYS ones. (author)

  12. Ground source heat pump technology in colleges and universities to explore application%地源热泵技术在高校的探索应用

    Institute of Scientific and Technical Information of China (English)

    龚伟申

    2011-01-01

    Focuses on the Nanjing Railway,Suzhou Vocational and Technical College Campus Library case of ground-source heat pump systems engineering and operational effectiveness analysis that the ground-source heat pump air-conditioning and domestic water in the school application is feasible,energy-efficient,economy is also clear is worthy of dissemination and application.%介绍了南京铁道职业技术学院苏州校区图书馆地源热泵系统工程案例及运行效果分析,认为土壤源热泵在学校空调及生活用水的应用是可行的、节能的,经济性也是明显的,值得推广应用.

  13. Monitoring actual performance of ground source heat pump system using GPRS-based data transmission:A case analysis in Tangshan

    Institute of Scientific and Technical Information of China (English)

    杜红普; 孔祥飞; 李敏; 齐承英

    2015-01-01

    The energy efficiency monitoring is an essential precondition for ground source heat pump system’s controlling and energy saving operation. Based on the data monitoring applied in the school building, this work is focused on the parameters acquisition and operation analysis of the GSHP system in Tangshan. Results show the average COPs (coefficient of performance) are 2.85 and 2.70 in summer and winter, respectively, and heat(cold) unbalance underground existed after whole year operation. The analysis of data also indicates that the direct borehole air-conditioning saved some power consumption obviously in the early stage of summer and energy saving of the GSHP system depended remarkably on its operation and management level. Besides the observation points of ground temperature are laid for a large-scale GSHP system, and the hydraulic balance of the pipes group needs to be concerned specially in safeguarding better reliability.

  14. A ground water source heat pump for the air-conditioning of a supermarket; Une PAC sur nappe phreatique pour climatiser un hypermarche

    Energy Technology Data Exchange (ETDEWEB)

    Anon.

    2002-04-01

    A thermodynamical solution involving a ground water source heat pump and 19 roof top air-conditioners has been retained for the air-conditioning of a 41000 m{sup 2} supermarket of Colmar (Alsace, France). The supermarket is also equipped with a computer-monitored refrigeration system for the food products and a centralized technical management for the optimization of the installation operation. (J.S.)

  15. Investigating the effect of bottom boundary condition placement on ground heat storage in climate time scale simulations using ParflowE

    Science.gov (United States)

    Khorsandi, Ehsan; Kollet, Stefan; Venema, Victor; Simmer, Clemens

    2014-05-01

    Heat and water fluxes are key variables affecting the atmosphere-land surface interactions as well as transpiration by plants and geochemical cycles. At climate timescales, the subsurface thermal regime may impact the land surface energy balance via the ground heat flux and associated temperature feedbacks. As a matter of fact, since there is no real lower energy boundary condition, except the natural geothermal heat flux, the subsurface may act as an infinite heat sink in case of a positive temperature trend at the surface. However, due to computational reasons, climate models incorporate a shallow subsurface domain, and thus a shallow temperature boundary condition, which generally is of the Neumann type. This leads to a cumulative ground heat flux of zero over large time scales, which is not realistic, in case of a trend in air temperature. Additionally, the convection term of heat transfer in the subsurface and the memory effect of soil moisture on energy transport is also neglected in climate models by simplified parameterizations. Single soil column model experiments were performed with ParflowE as a subsurface model, which incorporates the more complete heat equation coupled to variably saturated flow, to study the effect of bottom boundary condition placement on ground heat storage and propagated temperature signals over large time-scale with respect to the hydro dynamic process and energy balances. Simulations were carried out over one hundred years (2002-2101) using 4 simple soil columns with the same soil characteristic, lateral boundary conditions and atmosphere forcing, but differing in depth (12, 24, 75 and 150m). After a spin-up period, the models were forced with step-change air temperature and GCM model results namely the IPCC RCP 8.5 scenarios, in order to identify the climate change signals in the subsurface and the associated feedbacks at the land surface. While in the deep soil column, temperature profiles show a heat distribution which is

  16. 集群竖埋管地热换热器传热简化分析方法%Simplified analysis of heat transfer for vertical multi-boreholes ground heat exchangers

    Institute of Scientific and Technical Information of China (English)

    于明志; 马腾腾; 张凯; 胡爱娟; 崔萍; 方肇洪

    2016-01-01

    提出利用几何对称性和部分埋管周围温度场呈近似相同周期性变化的特点,对集群竖埋管地热换热器传热分析进行简化的方法.在有限长线热源模型基础上,以无渗流矩阵形式布置的集群竖埋管地热换热器为例,利用该方法进行简化分析,提出采用代表性埋管矩阵代替原集群埋管地热换热器进行传热分析.结合代表性埋管矩阵和相应工况下的单根埋管传热进行分析,认为可以通过单根埋管的传热影响半径,确定地质条件、埋管几何参数、负荷及运行条件等相同情况下大型集群埋管换热器的代表性埋管矩阵.土壤热导率大小影响代表性埋管矩阵的规模,本文条件下土壤热导率越大,确定的代表性埋管矩阵越小.%Taking geometric symmetry and the approximately same periodic variation of the temperature field around partial buried pipes into account, simplified analysis of heat transfer for vertical multi-boreholes ground heat exchangers was carried out. On the basis of finite line heat source model, an example of non-seepage matrix layout of vertical multi-boreholes ground heat exchangers was selected to simplify the analysis of heat transfer. For the purpose of simplification on heat transfer analysis, representative buried pipe matrix (RBPM) was proposed in place of the original vertical multi-boreholes ground heat exchangers. Through the analysis on heat transfer of a single buried pipe and RBMP, it was considered that the heat transfer of RBPM can be determined according to the influencing radius of heat transfer of a single buried pipe under the same conditions of the geological conditions, geometry parameters, loads and operation conditions. Thermal conductivity of soil affects the scale of RBPM. Under the conditions in this article, the larger thermal conductivity of the soil is, the smaller scale of RBPM is.

  17. Extension and application of a scaling technique for duplication of in-flight aerodynamic heat flux in ground test facilities

    NARCIS (Netherlands)

    Veraar, R.G.

    2009-01-01

    To enable direct experimental duplication of the inflight heat flux distribution on supersonic and hypersonic vehicles, an aerodynamic heating scaling technique has been developed. The scaling technique is based on the analytical equations for convective heat transfer for laminar and turbulent bound

  18. On application of heating ventilation air-conditioner energy-saving issue and ground source heat pump%谈暖通空调节能问题与地源热泵的实际应用

    Institute of Scientific and Technical Information of China (English)

    黄长晖

    2012-01-01

    针对暖通空调:市能问题进行了研究,结合实际案例介绍了地源热泵在工程项目中的应用,通过与以城市供热为热源的室内散热器取暖方案进行对比分析,得出地源热泵系统能够有效解决空调系统节能问题,值得推广。%The paper researches the energy-saving issue of heating air-conditioner, introduces the application of the ground source heat pump in the engineering program by combining with the factual cases, undertakes the comparative analysis of the heating scheme for the indoor radiator which regards the urban heating supply as the source, and concludes the ground source heat pump system can solve the energy-saving issue of the air-conditioner system, so it can be further applied.

  19. 某商业建筑地下水源热泵系统设计%The System Design of Ground Water Heat Pumps in a Commercial Building

    Institute of Scientific and Technical Information of China (English)

    高亮

    2014-01-01

    地下水源热泵是地源热泵的一种形式。与土壤源热泵比,其具有投资小、运行费用低的特点,因此在工程实际中可推广性更强。文章以某商业建筑为例,以建筑形式、面积为基础,进行了水源热泵系统设计,并对工程投资和运行费用进行了估算。%Ground water heat pump is a form of ground source heat pumps, and compare with the soil source heat pump, its investment smal and operating cost low, so it has stronger generalization in engineering practice. This article takes a commercial building as example and based on the architectural form and area, designs the water heat pump system and estimate the engineering investment and operation cost.

  20. 多功能地源热泵机组的节能性分析%Energy-saving Analysis on Multifunction Ground Source Heat Pump Unit

    Institute of Scientific and Technical Information of China (English)

    尹永存; 曾庆新

    2014-01-01

    According to the requirements of cooling, heating and hot-water for villa project in Zhengzhou, the advantages and disadvantages of the two kinds of air-conditioning system are compared, those are household air-conditioning unit plus heat-pump water heater, and multifunction ground source heat pump unit. And its energy-saving is analyzed.%结合郑州某别墅工程对供冷、供暖、热水的需求,对比了两种不同空调系统:户式空调机组+热泵热水器,和多功能地源热泵机组性能的优劣;并进行了节能性分析。

  1. Multi-channel transmit/receive metal detector coil design for vehicular applications

    Science.gov (United States)

    Yesil, Mehmet Ali; Yeǧin, Korkut; Bellikli, Hasan; Tura, Levent; Nazlı, Hakki; Daǧ, Mahmut

    2014-05-01

    Metal detector coil design has been matured to great extent over the years. However, vehicle mounted or remotely operated metal detectors require different specifications and these specifications dictate multiple transmit and receive coils operating in various settings. Unlike handheld operation, detector is more susceptible to metallic body of the vehicle. Moreover, ground calibration is also different than handheld devices. Coil geometries and intercoupling between them play a significant role in system design and performance. In this study, we study different coil geometries for vehicular applications. Starting from well-known coil geometries, we placed coils on dry, wet and ferrous soil to understand the interaction mechanism. Simulation studies are performed in frequency domain but the results are all applicable to time domain pulse based detector systems.

  2. Predictive model for the reduction of heat resistance of Listeria monocytogenes in ground beef by the combined effect of sodium chloride and apple polyphenols.

    Science.gov (United States)

    Juneja, Vijay K; Altuntaş, Evrim Güneş; Ayhan, Kamuran; Hwang, Cheng-An; Sheen, Shiowshuh; Friedman, Mendel

    2013-06-03

    We investigated the combined effect of three internal temperatures (57.5, 60, and 62.5°C) and different concentrations (0 to 3.0 wt/wt.%) of sodium chloride (NaCl) and apple polyphenols (APP), individually and in combination, on the heat-resistance of a five-strain cocktail of Listeria monocytogenes in ground beef. A complete factorial design (3×4×4) was used to assess the effects and interactions of heating temperature, NaCl, and APP. All 48 combinations were tested twice, to yield 96 survival curves. Mathematical models were then used to quantitate the combined effect of these parameters on heat resistance of the pathogen. The theoretical analysis shows that compared with heat alone, the addition of NaCl enhanced and that of APP reduced the heat resistance of L. monocytogenes measured as D-values. By contrast, the protective effect of NaCl against thermal inactivation of the pathogen was reduced when both additives were present in combination, as evidenced by reduction of up to ~68% in D-values at 57.5°C; 65% at 60°C; and 25% at 62.5°C. The observed high antimicrobial activity of the combination of APP and low salt levels (e.g., 2.5% APP and 0.5% salt) suggests that commercial and home processors of meat could reduce the salt concentration by adding APP to the ground meat. The influence of the combined effect allows a reduction of the temperature of heat treatments as well as the salt content of the meat. Meat processors can use the predictive model to design processing times and temperatures that can protect against adverse effects of contaminated meat products. Additional benefits include reduced energy use in cooking, and the addition of antioxidative apple polyphenols may provide beneficial health affects to consumers.

  3. Performance evaluation of a ground-source heat pump system utilizing a flowing well and estimation of suitable areas for its installation in Aizu Basin, Japan

    Science.gov (United States)

    Shrestha, Gaurav; Uchida, Youhei; Kuronuma, Satoru; Yamaya, Mutsumi; Katsuragi, Masahiko; Kaneko, Shohei; Shibasaki, Naoaki; Yoshioka, Mayumi

    2017-08-01

    Development of a ground-source heat pump (GSHP) system with higher efficiency, and evaluation of its operating performance, is essential to expand the growth of GSHP systems in Japan. A closed-loop GSHP system was constructed utilizing a flowing (artesian) well as a ground heat exchanger (GHE). The system was demonstrated for space-heating and space-cooling of a room (area 126.7 m2) in an office building. The average coefficient of performance was found to be 4.5 for space-heating and 8.1 for space-cooling. The maximum heat exchange rate was 70.8 W/m for space-heating and 57.6 W/m for space-cooling. From these results, it was determined that a GSHP system with a flowing well as a GHE can result in higher performance. With this kind of highly efficient system, energy saving and cost reduction can be expected. In order to assess appropriate locations for the installation of similar kinds of GSHP systems in Aizu Basin, a suitability map showing the distribution of groundwater up-flowing areas was prepared based on the results of a regional-scale three-dimensional analytical model. Groundwater up-flowing areas are considered to be suitable because the flowing well can be constructed at these areas. Performance evaluation of the GSHP system utilizing the flowing well, in conjunction with the prepared suitability map for its installation, can assist in the promotion of GSHP systems in Japan.

  4. Performance evaluation of a ground-source heat pump system utilizing a flowing well and estimation of suitable areas for its installation in Aizu Basin, Japan

    Science.gov (United States)

    Shrestha, Gaurav; Uchida, Youhei; Kuronuma, Satoru; Yamaya, Mutsumi; Katsuragi, Masahiko; Kaneko, Shohei; Shibasaki, Naoaki; Yoshioka, Mayumi

    2017-02-01

    Development of a ground-source heat pump (GSHP) system with higher efficiency, and evaluation of its operating performance, is essential to expand the growth of GSHP systems in Japan. A closed-loop GSHP system was constructed utilizing a flowing (artesian) well as a ground heat exchanger (GHE). The system was demonstrated for space-heating and space-cooling of a room (area 126.7 m2) in an office building. The average coefficient of performance was found to be 4.5 for space-heating and 8.1 for space-cooling. The maximum heat exchange rate was 70.8 W/m for space-heating and 57.6 W/m for space-cooling. From these results, it was determined that a GSHP system with a flowing well as a GHE can result in higher performance. With this kind of highly efficient system, energy saving and cost reduction can be expected. In order to assess appropriate locations for the installation of similar kinds of GSHP systems in Aizu Basin, a suitability map showing the distribution of groundwater up-flowing areas was prepared based on the results of a regional-scale three-dimensional analytical model. Groundwater up-flowing areas are considered to be suitable because the flowing well can be constructed at these areas. Performance evaluation of the GSHP system utilizing the flowing well, in conjunction with the prepared suitability map for its installation, can assist in the promotion of GSHP systems in Japan.

  5. Structural and biochemical characterizations of an intramolecular tandem coiled coil protein.

    Science.gov (United States)

    Shin, Donghyuk; Kim, Gwanho; Kim, Gyuhee; Zheng, Xu; Kim, Yang-Gyun; Lee, Sangho

    2014-12-12

    Coiled coil has served as an excellent model system for studying protein folding and developing protein-based biomaterials. Most designed coiled coils function as oligomers, namely intermolecular coiled coils. However, less is known about structural and biochemical behavior of intramolecular coiled coils where coiled coil domains are covalently linked in one polypeptide. Here we prepare a protein which harbors three coiled coil domains with two short linkers, termed intramolecular tandem coiled coil (ITCC) and characterize its structural and biochemical behavior in solution. ITCC consists of three coiled coil domains whose sequences are derived from Coil-Ser and its domain swapped dimer. Modifications include positioning E (Glu) residue at "e" and K (Lys) at "g" positions throughout heptad repeats to enhance ionic interaction among its constituent coiled coil domains. Molecular modeling of ITCC suggests a compact triple helical bundle structure with the second and the third coiled coil domains forming a canonical coiled coil. ITCC exists as a mixture of monomeric and dimeric species in solution. Small-angle X-ray scattering reveals ellipsoidal molecular envelopes for both dimeric and monomeric ITCC in solution. The theoretically modeled structures of ITCC dock well into the envelopes of both species. Higher ionic strength shifts the equilibrium into monomer with apparently more compact structure while secondary structure remains unchanged. Taken together, our results suggest that our designed ITCC is predominantly monomeric structure through the enhanced ionic interactions, and its conformation is affected by the concentration of ionic species in the buffer.

  6. Quench and recovery characteristics of a racetrack double pancake coil wound with YBCO-coated conductor

    Energy Technology Data Exchange (ETDEWEB)

    Kim, H M; Kwon, Y K; Lee, J D [Korea Electrotechnology Research Institute, Changwon (Korea, Republic of); Song, J B; Lee, H G [Department of Materials Science and Engineering, Korea University, Seoul (Korea, Republic of)], E-mail: haigunlee@korea.ac.kr

    2009-02-15

    The reliability of high temperature superconducting (HTS) racetrack coils is one of the most important factors for the development of large-scale rotating machines. However, it is necessary to investigate the stability and normal zone propagation characteristics of racetrack coils for large-scale applications such as ship propulsion motors and power generators. In this study, the quench/recovery characteristics of a racetrack-type, double pancake (DP) coil, which could be applied to HTS rotating machines, were investigated using the voltage and temperature profiles in a cryogenic conduction cooling system. The minimum quench heating flux and quench propagation velocity of the racetrack DP coil are also discussed.

  7. Quench and recovery characteristics of a racetrack double pancake coil wound with YBCO-coated conductor

    Science.gov (United States)

    Kim, H. M.; Kwon, Y. K.; Lee, J. D.; Song, J. B.; Lee, H. G.

    2009-02-01

    The reliability of high temperature superconducting (HTS) racetrack coils is one of the most important factors for the development of large-scale rotating machines. However, it is necessary to investigate the stability and normal zone propagation characteristics of racetrack coils for large-scale applications such as ship propulsion motors and power generators. In this study, the quench/recovery characteristics of a racetrack-type, double pancake (DP) coil, which could be applied to HTS rotating machines, were investigated using the voltage and temperature profiles in a cryogenic conduction cooling system. The minimum quench heating flux and quench propagation velocity of the racetrack DP coil are also discussed.

  8. Manufacturing of a REBCO racetrack coil using thermoplastic resin aiming at Maglev application

    Energy Technology Data Exchange (ETDEWEB)

    Mizuno, Katsutoshi, E-mail: mizuno.katsutoshi.14@rtri.or.jp; Ogata, Masafumi; Hasegawa, Hitoshi

    2015-11-15

    Highlights: • We propose a novel REBCO coil structure which applies thermoplastic resin. • The thermoplastic resin bonds the coil winding and cooling plates. • The adhesiveness of the resin is strong enough to withstand the thermal stress. • The thermoplastic resin does not cause the degradation because of its high viscosity. • We successfully made a full-scale racetrack REBCO coil with the thermoplastic resin. - Abstract: The REBCO coated conductor is a promising technology for the Maglev application in terms of its high critical temperature. The operating temperature of the on-board magnets can be around 40–50 K with the coated conductor. The REBCO coils are cooled by cryocoolers directly, and hence the thermal design of the REBCO coils significantly changes from that of LTS coils. We have developed a novel REBCO coil structure using thermoplastic resin. The coil is not impregnated and the thermoplastic resin is used to bond the coil winding and the heat transfer members, e.g. copper and aluminum plates. The viscosity of the thermoplastic resin is high enough for the thermoplastic resin not to permeate between the turns in the coil. Therefore, the thermal stress does not occur and the risk of degradation is removed. This paper contains the following three topics. First, the thermal resistance of the thermoplastic resin was measured at cryogenic temperature. Then, a small round REBCO coil was experimentally produced. It has been confirmed that the thermoplastic resin does not cause the degradation and, the adhesion between the coil winding and copper plates withstands the thermal stress. Finally, we successfully produced a full-scale racetrack REBCO coil applying the coil structure with the thermoplastic resin.

  9. Effect of Metal Proximity on a Pulsed Copper Coil

    Science.gov (United States)

    Johnson, H. K.; Schaffner, D. A.; Brown, M. R.; Kaur, M.; Fiedler-Kawaguchi, C.

    2016-10-01

    Generating and accelerating plasma in a stainless steel chamber affects the magnetic fields inside. These effects will decrease the field due to a pulsed coil (which will later be used to accelerate plasma) inside the chamber. This work is being done in conjunction with the Swarthmore Spheromak Experiment. Both facilities are collaborating in an attempt to accelerate and compress plasma as part of ARPA-E's Accelerating Low-Cost Plasma Heating and Assembly (ALPHA) program. Measurements of the impact of the chamber on the coil's magnetic fields were made using a B-dot probe inside the coil, which was placed at incremental distances from a metal plate. As the coil is moved from the plate, the plate's interference with the field was seen to exponentially decay. This process was repeated for stainless steel, aluminum, and copper, and a range of voltages (500-800V). At least seventy percent of the original signal was recovered within two inches. Pulsing the coil inside the stainless steel chamber resulted in signals about one third the strength of those measured outside of the chamber. The results of this experiment will be used to guide development of the stainless steel pulse-coil system for the Swarthmore ALPHA project. Work supported by ARPA-E ALPHA program.

  10. Cryocooled Facilities for Superconducting Coils Testing in Gaseous Helium

    Science.gov (United States)

    Naumov, A. V.; Keilin, V. E.; Kovalev, I. A.; Surin, M. I.; Shcherbakov, V. I.; Shevchenko, S. A.; Ilin, A. A.

    Two superconducting coil test facilities equipped by Sumitomo SRDK-415D cryocoolers were developed, manufactured and tested. The motivation for their constructing was to make cheaper the testing (and especially training of LTS magnets) by liquid helium (LHe) saving. It is well known that the helium price increases rapidly and this tendency most probably will continue for a long time, as the demand of helium grows faster than its production. The utilization of heat-exchange gas considerably reduces many problems, that arise in the design of completely dry LTS magnets. The goal was to decrease or even completely avoid the consumption of rather expensive liquid helium for testing the laboratory size Nb-Ti and Nb3Sn coils including their training process. Several superconducting magnets were tested by using these facilities. For example, the first facility was successfully used for testing of 13 T, 60 kg coil cooled by cryocooler in helium gas (several torr pressure) heat exchange atmosphere. The precooling time was about 45 hours. The quench current (240 A at 4.2 K) was equal to that reached in the pool boiling LHe cryostat. The second facility with 420 mm wide access bore can be used for testing of corresponding size superconducting coils with very modest consumption of liquid helium with its level well below the lower flange of the coil. Each test facility is equipped by 2 pairs of HTS current leads. Design and operational experience of one of them is described.

  11. Effect of coiling temperature on microstructure and properties of X100 pipeline steel

    Energy Technology Data Exchange (ETDEWEB)

    Cheng, Shixia, E-mail: dongchuke@163.com [State Key Laboratory for Mechanical Behavior of Materials, Xi' an Jiaotong University, Xi' an 710049 (China); Zhang, Xiaoyong [School of Materials Science and Engineering, Xi' an Shiyou University, Xi' an 710065 (China); Zhang, Jianxun [State Key Laboratory for Mechanical Behavior of Materials, Xi' an Jiaotong University, Xi' an 710049 (China); Feng, Yaorong [CNPC Tubular Goods Research Institute, Xi' an 710077 (China); Ma, Jing [Xi' an Aeronautical Polytechnic Institute, Xi' an 710089 (China); Gao, Huilin [School of Materials Science and Engineering, Xi' an Shiyou University, Xi' an 710065 (China)

    2016-06-01

    Multiphase structure of bainite and M/A(martensite/austenite constituent) can be obtained through coiling continuous-HOP (Heating On-line Partitioning) technology, resulting in excellent deformability for X100 pipeline steel. The microstructure and properties of the steel at different coiling temperatures were investigated by means of mechanical properties test, microscopic analysis and X-ray diffraction method. The results show that with the increase of coiling temperature, the strength decreases and the ductility increases because of the widening of bainite laths, the decrease of bainite content and dislocation density. However, because of the formation of martensite, the precipitation of carbides and the decrease of retained austenite at high coiling temperatures, the strength increases and the ductility decreases. Low yield ratio, high uniform elongation and high strain hardening exponent can be achieved at appropriate coiling temperatures through coiling continuous-HOP technology, which endows the steel with good ductility and excellent deformability.

  12. CCHMM_PROF: a HMM-based coiled-coil predictor with evolutionary information

    DEFF Research Database (Denmark)

    Bartoli, Lisa; Fariselli, Piero; Krogh, Anders;

    2009-01-01

    MOTIVATION: The widespread coiled-coil structural motif in proteins is known to mediate a variety of biological interactions. Recognizing a coiled-coil containing sequence and locating its coiled-coil domains are key steps towards the determination of the protein structure and function. Different...... tools are available for predicting coiled-coil domains in protein sequences, including those based on position-specific score matrices and machine learning methods. RESULTS: In this article, we introduce a hidden Markov model (CCHMM_PROF) that exploits the information contained in multiple sequence...... alignments (profiles) to predict coiled-coil regions. The new method discriminates coiled-coil sequences with an accuracy of 97% and achieves a true positive rate of 79% with only 1% of false positives. Furthermore, when predicting the location of coiled-coil segments in protein sequences, the method reaches...

  13. Coiled-coil conformation of a pentamidine-DNA complex.

    Science.gov (United States)

    Moreno, Tadeo; Pous, Joan; Subirana, Juan A; Campos, J Lourdes

    2010-03-01

    The coiled-coil structure formed by the complex of the DNA duplex d(ATATATATAT)(2) with pentamidine is presented. The duplex was found to have a mixed structure containing Watson-Crick and Hoogsteen base pairs. The drug stabilizes the coiled coil through the formation of cross-links between neighbouring duplexes. The central part of the drug is found in the minor groove as expected, whereas the charged terminal amidine groups protrude and interact with phosphates from neighbouring molecules. The formation of cross-links may be related to the biological effects of pentamidine, which is used as an antiprotozoal agent in trypanosomiasis, leishmaniasis and pneumonias associated with AIDS. The DNA sequence that was used is highly abundant in most eukaryotic genomes. However, very few data are available on DNA sequences which only contain A.T base pairs.

  14. Coils and the Electromagnet Used in the Joule Balance at the NIM

    CERN Document Server

    Zhang, Zhonghua; Han, Bing; Lu, Yunfeng; Li, Shisong; Xu, Jinxin; Wang, Gang

    2015-01-01

    In the joule balance developed at National Institute of Metrology (NIM), the dynamic phase of a watt balance is replaced by the mutual inductance measurement in an attempt to provide an alternative method for the kg redefinition. But for this method a rather large current in the exciting coil, is needed to offer the necessary magnetic field in the force weighing phase, and the coil heating becomes an important uncertainty source. To reduce coil heating, a new coil system, in which a ferromagnetic material is used to increase the magnetic field was designed recently. But adopting the ferromagnetic material brings the difficulty from the nonlinear characteristic of material. This problem can be removed by measuring the magnetic flux linkage difference of the suspended coil at two vertical positions directly to replace the mutual inductance parameter. Some systematic effects of this magnet are discussed.

  15. Applied research of a ground water thermoelectric heat pump system%地下水源热电热泵的应用研究

    Institute of Scientific and Technical Information of China (English)

    马国远

    2001-01-01

    Develops a mathematical model of the system and simulates it with computer based on the state-of-the-art performance of the thermoelectric material, compares the results with those of a conventional ground water heat pump system under the identical inlet water temperature and water flow rate and finds that the thermoelectric system is more competitive especially when the ground water temperature is under 18 ℃ but much poorer in heating performance leading it to be suitable for applications with primary heating demand.%建立了以地下水为热源的热电热泵系统的数学模型,并根据热电材料的技术性能对该系统作了计算机模拟分析,比较计算结果与进水温度和流量相同的传统地下水源热泵系统发现,热电热泵在制冷工况特别是地下水温低于18 ℃时具有很强的竞争力,但制热性能较差,因此适用于全年以制冷负荷为主的场合。

  16. Research on heat transfer performance of ground heat exchangers in continuous and intermittent operation condition%连续与间歇运行工况下地埋管换热器的换热特性研究

    Institute of Scientific and Technical Information of China (English)

    董艳芳; 王磊; 曾召田; 金樾

    2014-01-01

    为了研究地埋管换热器在变负荷下连续运行与间歇运行的换热性能,基于有限长线热源渗流模型建立竖直地埋管钻孔外准三维非稳态传热模型,应用叠加原理计算钻孔群中钻孔壁温度场及地埋管内流体温度场.在存在地下水水平渗流的情况下,研究了变负荷连续运行模式下不同渗流速度、不同运行工况及不同钻孔位置对地埋管换热器的换热性能的影响.结果表明,在连续运行模式下,边缘位置的钻孔及较大的渗流速度能够增强地埋管换热器的换热性能;在间歇运行模式下,地埋管换热器的运行份额越小,其制冷效果越好,反之,制冷效果越差;在间歇运行工况下,土壤温度能在系统间歇期内得到一定程度的恢复,从而更好地提高地热能的利用率.%In order to investigate heat transfer performance of ground heat exchangers in continuous and intermittent operation mode under condition of dynamic load,a quasi-three-dimensional transient heat transfer model for borehole exterior of vertical ground exchanger is built based on finite line heat source groundwater advection model; The superposition principle is used to calculate borehole wall temperature field and temperature field of fluid in buried pipe among the boreholes.While groundwater is flowing in horizontal direction,the heat transfer performances of vertical ground heat exchangers are mainly studied at different seepage velocity,different operational states and different positions of borehole in continuous operation mode under dynamic load.The results show that the heat transfer performance,under the condition that boreholes are at the edge or the seepage velocity is high,may be enhanced in continuous running; and at low proportion of operation time of ground heat exchangers in the intermittent operation mode,cooling effect is better,whereas theirs cooling effect is worse.Temperature of the soil gets recovery in certain degree in the

  17. Can Magnetic Coil Ease Tinnitus?

    Science.gov (United States)

    ... Research Updates Technology Horizons Can magnetic coil ease tinnitus? VA trial aims to find out February 3, ... pain. See, for example, this 2009 review study . Tinnitus and Veterans Tinnitus has been one of the ...

  18. First coil for the SC

    CERN Multimedia

    CERN PhotoLab

    1955-01-01

    The coils for the SC magnet were stored in the large hangar of the Cointrin Airport (to make sure that they would be available before snow and ice would block the roads and canals from Belgium, where they were built).

  19. Nylon screws make inexpensive coil forms

    Science.gov (United States)

    Aucoin, G.; Rosenthal, C.

    1978-01-01

    Standard nylon screws act as coil form copper wire laid down in spiral thread. Completed coil may be bonded to printed-circuit board. However, it is impossible to tune coil by adjusting spacing between windings, technique sometimes used with air-core coils.

  20. Nylon screws make inexpensive coil forms

    Science.gov (United States)

    Aucoin, G.; Rosenthal, C.

    1978-01-01

    Standard nylon screws act as coil form copper wire laid down in spiral thread. Completed coil may be bonded to printed-circuit board. However, it is impossible to tune coil by adjusting spacing between windings, technique sometimes used with air-core coils.

  1. HELMHOLTZ COILS FOR MEASURING MAGNETIC MOMENTS

    Directory of Open Access Journals (Sweden)

    P. N. Dobrodeyev

    2013-01-01

    Full Text Available The optimal configuration of the double Helmholtz coils for measuring of the magnetic dipole moments was defined. It was determined that measuring coils should have round shape and compensative coils – the square one. Analytically confirmed the feasibility of the proposed configuration of these coils as primary transmitters of magnetic dipole moments.

  2. Study on Recharge Ability of Ground Water Heat Pump System%地下水源热泵系统中回灌能力分析

    Institute of Scientific and Technical Information of China (English)

    赵宏亮

    2012-01-01

    近年,地下水源热泵技术在我国被广泛应用,并在节能、环保等方面取得了一定效益.但是,回灌问题仍是困扰我国地下水源热泵发展的瓶颈.以唐山市丰润区乡居假日住宅区A4区地下水源热泵系统的应用为例,从区域水文地质条件方面,对水源热泵系统中地下水回灌能力进行了分析,指出开展地下水源热泵项目时,掌握热源井所在区域水文地质条件的重要性.探讨了影响地下水回灌能力的关键因素,其中包括区域水文地质条件、热源井成井工艺、回灌井阻塞以及地下水回灌方式.%In recent years, ground water beat pump technology has been widely applied in China and has made certain benefits in energy saving and environmental protection. However, groundwater recharge is still the main difficulty. This paper studied on the recharge of ground water heat pump according to the local hydrogeologic conditions at A4 area in the Fengrun countryside holiday block in Tangshan City, pointed out that the local hydrogeological condition is very important, and discussed the key factors impacting the recharge ability of ground water heat pump, including local hydrogeologic conditions,heat source well completion technology, clogging problem of disposal well and groundwater recharge mode.

  3. STRUCTURE AND CHARACTERISTICS OF TI-AL-NI SYSTEM COVERING, APPLIED ON THE STEEL GROUND USING ELECTRON-BEAM HEATING

    Directory of Open Access Journals (Sweden)

    I. V. Murashova

    2011-01-01

    Full Text Available The morphology of the system Ti-Al-Ni covering, received by means of self-distributing high-temperature synthesis, initiated by electron-beam heating, on the basis of steel St3 is investigated.

  4. Ground-water-coupled heat pump for heating the field and for cooling rooms at the Arnheim multi-purpose ``Gelredome`` stadium; Grundwassergekoppelte Waermepumpe fuer die Spielfeldheizung und Raumkuehlung des Mehrzweckstadiums ``Gelredome`` in Arnheim

    Energy Technology Data Exchange (ETDEWEB)

    Bakema, G.; Snijders, A.L. [IF Technology bv, Arnheim (Netherlands)

    1997-12-01

    Some of the things that the Gelredome multi-purpose stadium will be equipped with will be a horizontal draw-out lawn, solar collectors, and a sliding roof. But the nicest piece of technology that the site has to offer has been buried in the ground for several ten thousand years: a ground water aquifer. This layer of sand is conditioned for temporary storage of surplus energy obtained by heating and cooling with the aid of a heat pump. The paper deals with this specific aspect of energy storage. But to begin with, a general overview of the use of heat pumps in the Netherlands is given, especially where they are combined with energy storage. (orig.) [Deutsch] Das Gelredome-Stadium, ein Mehrzweckstadium, wird unter anderem mit einer ausfahrbaren Grasflaeche, mit Sonnenkollektoren und mit einem Schiebedach ausgestattet. Das schoenste Stueckchen Technik verbirgt sich dort jedoch schon seit mehreren zehntausend Jahren unter der Erdoberflaeche: Ein Grundwasserleiter. Diese Sandschicht wird fuer die zeitweilige Speicherung des Energieueberschusses, der beim Heizen und Kuehlen mit einer Waermepumpe zur Verfuegung kommt, eingerichtet werden. Auf diesen spezifischen Fall der Energiespeicherung wird gleich eingegangen. Zuerst aber noch eine allgemeine Uebersicht ueber die Lage in den Niederlanden in bezug auf Waermepumpen und insbesondere, wenn diese mit Energiespeicherung kombiniert wird. (orig.)

  5. Efficient ground-state cooling of an ion in a large room-temperature linear Paul trap with a sub-Hertz heating rate

    DEFF Research Database (Denmark)

    Poulsen, Gregers; Miroshnychenko, Yevhen; Drewsen, Michael

    2012-01-01

    We demonstrate efficient resolved sideband laser cooling (99±1% ground-state population) of a single 40Ca+ ion in a large linear Paul trap (electrode spacing of 7 mm) operated at an rf drive frequency of just 3.7 MHz. For ion oscillation frequencies in the range 280–585 kHz, heating rates below...... or about one motional quantum per second have been measured at room temperature. The results, obtained under these unconventional sideband cooling conditions, pave the way for a range of new types of cold ion experiments, including spectroscopy of molecular ions as well as ultracold chemistry....

  6. Comparison of a single optimized coil and a Helmholtz pair for magnetic nanoparticle hyperthermia.

    Science.gov (United States)

    Nieskoski, Michael D; Trembly, B Stuart

    2014-06-01

    Magnetic nanoparticles in a tumor can induce therapeutic heating when energized by an alternating magnetic field from a current-carrying coil outside the body. We analyzed a single-turn, air-core coil carrying a filamentary current to quantify the power absorbed by: a) magnetic nanoparticles at depth in tissue and b) superficial tissue in response to induced eddy currents; we defined this quotient as power ratio (PR). Given some limit on the eddy current heating tolerated by an alert patient, maximizing the PR maximizes the power absorbed in the tumor; all else being equal, this increases the thermal dose delivered to the tumor. The mean eddy current heating rate tolerated in four clinical studies we reviewed equaled 12.5 kW/m (3). We differentiated our analytical expression for PR with respect to the radius of the coil to find the value of radius that maximizes PR. Under reasonable simplifying assumptions, the optimal value of coil radius equaled 1.187 times the depth of the nanoparticle target below the body surface. We also derived the PR of two coils surrounding the body configured as a Helmholtz pair. We computed PR for combinations of nanoparticle depths below the surface and axial locations with respect to the coils. At depths less than 4.6 cm, the optimized single coil had a higher PR than that of the Helmholtz pair and furthermore produced less total ohmic heating within the coil. These results were independent of driving frequency, nanoparticle concentration, tissue electrical conductivity, and magnetic nanoparticle heating rate, provided the latter is assumed to be proportional to the product of frequency and the square of the local magnetic field. This paper supports the clinical application of current-carrying coils to deliver efficacious hyperthermia therapy to tumors injected with magnetic nanoparticles.

  7. Voice Coil Percussive Mechanism Concept for Hammer Drill

    Science.gov (United States)

    Okon, Avi

    2009-01-01

    A hammer drill design of a voice coil linear actuator, spring, linear bearings, and a hammer head was proposed. The voice coil actuator moves the hammer head to produce impact to the end of the drill bit. The spring is used to store energy on the retraction and to capture the rebound energy after each impact for use in the next impact. The maximum actuator stroke is 20 mm with the hammer mass being 200 grams. This unit can create impact energy of 0.4 J with 0.8 J being the maximum. This mechanism is less complex than previous devices meant for the same task, so it has less mass and less volume. Its impact rate and energy are easily tunable without changing major hardware components. The drill can be driven by two half-bridges. Heat is removed from the voice coil via CO2 conduction.

  8. Physics design of a saddle coil system for TCV

    Energy Technology Data Exchange (ETDEWEB)

    Rossel, J.X., E-mail: jonathan.rossel@epfl.ch; Moret, J.-M.; Martin, Y.; Pochon, G.

    2011-12-15

    Highlights: Black-Right-Pointing-Pointer The design of a saddle coil system for TCV is presented. Black-Right-Pointing-Pointer The system is designed for ELM control, error field correction and vertical control. Black-Right-Pointing-Pointer The issue of optimal design determination is addressed. Black-Right-Pointing-Pointer Electrical properties in the presence of a conducting wall are quantified. Black-Right-Pointing-Pointer Coil heating due to Joule effect and impact of plasma disruptions are considered. - Abstract: The upgrade project for TCV (Tokamak a Configuration Variable) includes the installation of a set of saddle coils, namely the saddle coil system (SCS), located and powered such as to create a helical magnetic perturbation. Using independent power supplies, the toroidal periodicity of this perturbation is tunable, allowing simultaneously edge localized modes (ELM) control through resonant magnetic perturbation (RMP), error field correction and vertical control. Other experimental applications, like resistive wall mode and rotation control, are also in view. In this article, the adequacy of two SCS designs, an in-vessel one and an ex-vessel one, is assessed with respect to the desired experimental applications. The current requirements and the system performances are also characterized. The conducting vessel wall is accounted for in a model used to determine the coupled response functions of the SCS, the screening of the magnetic perturbation by the wall, the induced voltages and currents during a plasma disruption and the maximal magnetic forces exerted on the SCS. A scaling of the SCS parameters with the number of coil turns is presented and the issue of coil heating and cooling is discussed.

  9. The Comparison Analysis of Energy Saving Performance of Ground-source Heat Pump and Air Cooled Heat Pump%土壤源热泵与风冷热泵节能性能比较分析

    Institute of Scientific and Technical Information of China (English)

    张敏; 苏令宇

    2013-01-01

    本课题通过一定的实验方案和实验平台,以及数据采集和比较,较全面地反映了土壤源热泵系统和风冷热泵系统在基本相同的外界条件下,采用土壤源热泵的节能优势。%This topic through a certain experiment schemes and experiment platform, and the data collection and comparison, reflects the energy saving advantage of ground-source heat pump in basically the same external conditions.

  10. Performance of Upgraded Cooling System for Lhd Helical Coils

    Science.gov (United States)

    Hamaguchi, S.; Imagawa, S.; Obana, T.; Yanagi, N.; Moriuchi, S.; Sekiguchi, H.; Oba, K.; Mito, T.; Motojima, O.; Okamura, T.; Semba, T.; Yoshinaga, S.; Wakisaka, H.

    2008-03-01

    Helical coils of the Large Helical Device (LHD) are large scale superconducting magnets for heliotron plasma experiments. The helical coils had been cooled by saturated helium at 4.4 K, 120 kPa until 2005. An upgrade of the cooling system was carried out in 2006 in order to improve the cryogenic stability of the helical coils and then it has been possible to supply the coils with subcooled helium at 3.2 K, 120 kPa. A designed mass flow of the supplied subcooled helium is 50 g/s. The subcooled helium is generated at a heat exchanger in a saturated helium bath. A series of two centrifugal cold compressors with gas foil bearing is utilized to lower the helium pressure in the bath. The supplied helium temperature is regulated by rotational speed of the cold compressors and power of a heater in the bath. The mass flow of the supplied helium is also controlled manually by a supply valve and its surplus is evaporated by ten heaters at the outlet above the coils. In the present study, the performance of the cooling system has been investigated and a stable operating method has also developed. As the result, it was confirmed that the performance of the upgraded cooling system satisfies the requirements.

  11. Testing of machine wound second generation HTS tape Vacuum Pressure Impregnated coils

    Science.gov (United States)

    Swaffield, D.; Lewis, C.; Eugene, J.; Ingles, M.; Peach, D.

    2014-05-01

    Delamination of second generation (2G) High Temperature Superconducting (HTS) tapes has previously been reported when using resin based insulation systems for wound coils. One proposed root cause is the differential thermal contraction between the coil former and the resin encapsulated coil turns resulting in the tape c-axis tensile stress being exceeded. Importantly, delamination results in unacceptable degradation of the superconductor critical current level. To mitigate the delamination risk and prove winding, jointing and Vacuum Pressure Impregnation (VPI) processes in the production of coils for superconducting rotating machines at GE Power Conversion two scaled trial coils have been wound and extensively tested. The coils are wound from 12mm wide 2G HTS tape supplied by AMSC onto stainless steel 'racetrack' coil formers. The coils are wound in two layers which include both in-line and layer-layer joints subject to in-process test. The resin insulation system chosen is VPI and oven cured. Tests included; insulation resistance, repeat quench and recovery of the superconductor, heat runs and measurement of n-value, before and after multiple thermal cycling between ambient and 35 Kelvin. No degradation of coil performance is evidenced.

  12. Computational analysis of residue contributions to coiled-coil topology.

    Science.gov (United States)

    Ramos, Jorge; Lazaridis, Themis

    2011-11-01

    A variety of features are thought to contribute to the oligomeric and topological specificity of coiled coils. In previous work, we examined the determinants of oligomeric state. Here, we examine the energetic basis for the tendency of six coiled-coil peptides to align their α-helices in antiparallel orientation using molecular dynamics simulations with implicit solvation (EEF1.1). We also examine the effect of mutations known to disrupt the topology of these peptides. In agreement with experiment, ARG or LYS at a or d positions were found to stabilize the antiparallel configuration. The modeling suggests that this is not due to a-a' or d-d' repulsions but due to interactions with e' and g' residues. TRP at core positions also favors the antiparallel configuration. Residues that disfavor parallel dimers, such as ILE at d, are better tolerated in, and thus favor the antiparallel configuration. Salt bridge networks were found to be more stabilizing in the antiparallel configuration for geometric reasons: antiparallel helices point amino acid side chains in opposite directions. However, the structure with the largest number of salt bridges was not always the most stable, due to desolvation and configurational entropy contributions. In tetramers, the extent of stabilization of the antiparallel topology by core residues is influenced by the e' residue on a neighboring helix. Residues at b and c positions in some cases also contribute to stabilization of antiparallel tetramers. This work provides useful rules toward the goal of designing coiled coils with a well-defined and predictable three-dimensional structure.

  13. Experiments Demonstrate Geothermal Heating Process

    Science.gov (United States)

    Roman, Harry T.

    2012-01-01

    When engineers design heat-pump-based geothermal heating systems for homes and other buildings, they can use coil loops buried around the perimeter of the structure to gather low-grade heat from the earth. As an alternative approach, they can drill well casings and store the summer's heat deep in the earth, then bring it back in the winter to warm…

  14. Performance and Carbon Emission Analysis on Glass-covering Greenhouse Heating with Ground Source Heat Pump Technology%玻璃温室地源热泵供暖性能与碳排放分析

    Institute of Scientific and Technical Information of China (English)

    柴立龙; 马承伟

    2012-01-01

    The heating test was conducted in a glass-covering multi-span greenhouse ( 756 m ) with groundwater-style GSHP technology. The heat quantity estimating models based on air enthalpy difference method ( AEDM) were developed according to the heating characteristics of GSHP. The economical performance and carbon footprint ( greenhouse gas emission level) of the GSHP was analyzed and compared with currently widely used coal fired heating system ( CFHs) and natural gas fired heating system (GFHs) based on investigated various energy sources price during heating tests. According to the compared results, the GSHPs heating cost is higher than CFHs, but lower than GFHs. Meanwhile, GSHPs CO2 emission during heating is higher than GFHs, but lower than CFHs.In view of the strong coupling between temperature and relative humidity in the greenhouse simulation system, an adaptive decoupling method based on dynamic matrix control was proposed. Taking the measure of feedforward compensation to eliminate interaction between channels of temperature and humidity, an adaptive decoupling algorithm by weighting was designed. The proposed method can adjust the decoupling parameters online under different operating modes, effectively overcome the effect of model severe mismatch to control accuracy. Compared with the traditional PID control, simulation and experimental results both indicated the proposed strategy greatly improved the control performance.%在北京地区一栋玻璃连栋温室(756 m2)中采用地下水式地源热泵(ground source heat pump,简称GSHP)技术进行了冬季供暖试验,并结合GSHP技术的供热特点构建了基于供热末端空气焓差法的供热量计算模型以及供热系统性能分析方法.根据供暖期北京地区能源价格水平,对比当前广泛使用的燃煤供暖系统和天然气供暖系统,系统地评价了GSHP技术的碳排放(温室气体排放水平)和供暖经济性.GSHP供暖成本低于同期燃气供暖,但

  15. Effect of pomegranate powder on the heat inactivation of Escherichia coli O157:H4 in ground chicken

    Science.gov (United States)

    Health concerns have led to a search for natural plant-based antimicrobials. Ellagic acid has been shown to have antimicrobial activity against foodborne pathogens. The objective of this study was to assess the effect of a high-ellagic acid commercial pomegranate on the heat resistance of Escherich...

  16. Coastal versus estuarine nursery grounds: Effect of differential temperature and heat waves on juvenile seabass, Dicentrarchus labrax

    Science.gov (United States)

    Vinagre, Catarina; Narciso, Luís; Cabral, Henrique N.; Costa, Maria J.; Rosa, Rui

    2012-08-01

    This study investigates the biological responses of juvenile fish (Dicentrarchus labrax), that live in both coastal and estuarine nurseries, to differential temperatures and summer heat wave events. More specifically, we compared mortality, growth, condition, metabolic response and thermal sensitivity of 0-group juveniles of D. labrax at temperatures that reflect the average summer temperature that they encounter in coastal and estuarine nurseries, and also the temperatures that they endure inside estuaries during heat wave events. The low mortality and peak growth and condition values registered at 24 °C suggest that estuarine average summer temperatures are more beneficial for the juveniles than coastal ones. The estuarine water temperature attained during heat waves resulted in higher mortality, arrested growth, lower condition and a steep increase in metabolism, indicating that this species is probably under thermal stress at 28 °C. Consequently, future predictions of frequent and prolonged heat waves in Southern Europe are expected to induce negative impacts in the biology and metabolic ecology of 0-group seabass juveniles in estuarine nurseries.

  17. 新型混合地源热泵的土壤热平衡性能模拟%Soil Thermal Balance Performance Simulation of the New Hybrid Ground Source Heat Pump

    Institute of Scientific and Technical Information of China (English)

    刘小银; 彭彪

    2015-01-01

    Ground source heat pump is a new kind of green energy technologies which is advantage in energy conservation and environmental protection. O ne of the severe problems in the process of application is the thermal imbalance of the heat absorption and release to the ground. To solve this problem, this paper presents a new type of hybrid ground source heat pump in which hot w ater systemis combined with air conditioning systemof ground source heat pump. As an example, make a simulation of a new ly designed air conditioning systemof a hotel in Changsha. By comparison of the conventional single ground source heat pump, this new hybrid ground source heat pump has been confirmed to solve the imbalance of the heat absorption and release to the ground, effectively improved the operation efficiency ofairconditioning unitmean while.%地源热泵是一种新型节能环保的绿色能源利用技术,在应用过程中,存在的较大问题之一就是对土壤的吸放热不平衡。针对此问题本文提出了一种新的混合地源热泵形式,将热水系统和地源热泵空调系统进行耦合,对长沙某宾馆进行了系统设计并用T R N SY S进行了长达30年的模拟。通过和传统单一的地源热泵空调系统比较,证实了该系统不仅能有效地解决土壤吸放热不平衡问题,而且有效地提高了机组的运行效率。

  18. Temperature profile along an induction heated, moving non-magnetic charge

    Energy Technology Data Exchange (ETDEWEB)

    Januszkiewicz, K.

    1984-01-01

    Induction heating system, comprising three sections of a heating coil connected in series and supplied from one source, will be discussed. The charge to be heated is a non-magnetic pipe moving with steady speed. The heating coil is water cooled. Digital methods are used to compute temperature variations along the charge from start up to steady state temperature and also to determine power development in the heating circuit. Cooling zones between the heating coil sections are taken into account.

  19. Coil optimization for electromagnetic levitation using a genetic like algorithm

    Science.gov (United States)

    Royer, Z. L.; Tackes, C.; LeSar, R.; Napolitano, R. E.

    2013-06-01

    The technique of electromagnetic levitation (EML) provides a means for thermally processing an electrically conductive specimen in a containerless manner. For the investigation of metallic liquids and related melting or freezing transformations, the elimination of substrate-induced nucleation affords access to much higher undercooling than otherwise attainable. With heating and levitation both arising from the currents induced by the coil, the performance of any EML system depends on controlling the balance between lifting forces and heating effects, as influenced by the levitation coil geometry. In this work, a genetic algorithm is developed and utilized to optimize the design of electromagnetic levitation coils. The optimization is targeted specifically to reduce the steady-state temperature of the stably levitated metallic specimen. Reductions in temperature of nominally 70 K relative to that obtained with the initial design are achieved through coil optimization, and the results are compared with experiments for aluminum. Additionally, the optimization method is shown to be robust, generating a small range of converged results from a variety of initial starting conditions. While our optimization criterion was set to achieve the lowest possible sample temperature, the method is general and can be used to optimize for other criteria as well.

  20. Energy storage and heat transfer characteristics of ground heat exchanger with phase change backfill materials%相变材料回填地埋管换热器蓄能传热特性

    Institute of Scientific and Technical Information of China (English)

    杨卫波; 孙露露; 吴晅

    2014-01-01

    为了探讨相变回填材料固液相变对地埋管换热器蓄能传热性能的影响,建立了带有相变的垂直U型埋管换热器传热数学模型,并利用显热容法对相变材料的相变问题进行了处理。基于模型的数值求解,分析了夏冬季运行工况下相变材料固液相变对U型埋管换热器蓄能性能及其周围土壤温度热响应特性的影响规律,结果表明:同样条件下,相变材料固液相变会减缓埋管周围土壤温度变化趋势,缩小埋管热影响区域;夏季工况采用较低相变温度、冬季采用较高相变温度的相变材料均可以明显改善其换热效果,同时相变潜热大的相变材料可以明显增加地埋管的蓄能效果。研究结论对于缓解土壤热影响区域、改善地埋管换热器的蓄能传热性能具有重要意义。%Ground source heat pump (GSHP) has been recognized as being among the cleanest, most energy efficient and cost effective systems for residential and commercial space’s heating and cooling applications. The main advantage of using the ground as the heat source or sink of the system is that the soil temperature at tens to hundreds of meters in depth is relatively constant and is generally lower in summer and higher in winter than that of ambient air temperature. This results in an overall improvement of the system performance and thus reduces operation costs. Therefore, GSHP systems have become increasingly popular in commercial and institutional buildings. Heat transfer around vertical ground heat exchanger (GHE) is a common problem for the design and operation of GSHP. The energy storage performance of GHE and its influences on the temperature thermal response characteristics of soil around it are important for a long-term high-efficient and steady operation of GSHP systems. Thus, to enhance energy storage performance of GHE and, at the same time, reduce the effects of thermal diffuse on soil temperature are key

  1. The structure of the GemC1 coiled coil and its interaction with the Geminin family of coiled-coil proteins

    Energy Technology Data Exchange (ETDEWEB)

    Caillat, Christophe; Fish, Alexander [The Netherlands Cancer Institute, 1066 CX Amsterdam (Netherlands); Pefani, Dafni-Eleftheria; Taraviras, Stavros; Lygerou, Zoi [University of Patras, 26505 Rio, Patras (Greece); Perrakis, Anastassis, E-mail: a.perrakis@nki.nl [The Netherlands Cancer Institute, 1066 CX Amsterdam (Netherlands)

    2015-10-31

    The GemC1 coiled-coil structure has subtle differences compared with its homologues Geminin and Idas. Co-expression experiments in cells and biophysical stability analysis of the Geminin-family coiled coils suggest that the GemC1 coiled coil alone is unstable. GemC1, together with Idas and Geminin, an important regulator of DNA-replication licensing and differentiation decisions, constitute a superfamily sharing a homologous central coiled-coil domain. To better understand this family of proteins, the crystal structure of a GemC1 coiled-coil domain variant engineered for better solubility was determined to 2.2 Å resolution. GemC1 shows a less typical coiled coil compared with the Geminin homodimer and the Geminin–Idas heterodimer structures. It is also shown that both in vitro and in cells GemC1 interacts with Geminin through its coiled-coil domain, forming a heterodimer that is more stable that the GemC1 homodimer. Comparative analysis of the thermal stability of all of the possible superfamily complexes, using circular dichroism to follow the unfolding of the entire helix of the coiled coil, or intrinsic tryptophan fluorescence of a unique conserved N-terminal tryptophan, shows that the unfolding of the coiled coil is likely to take place from the C-terminus towards the N-terminus. It is also shown that homodimers show a single-state unfolding, while heterodimers show a two-state unfolding, suggesting that the dimer first falls apart and the helices then unfold according to the stability of each protein. The findings argue that Geminin-family members form homodimers and heterodimers between them, and this ability is likely to be important for modulating their function in cycling and differentiating cells.

  2. Deformation of Linked Polymer Coils

    Institute of Scientific and Technical Information of China (English)

    董朝霞; 李明远; 吴肇亮; 林梅钦

    2003-01-01

    Linked polymer solution (LPS) is defined as the solution of linked polymer coils (LPCs) dispersed in water, composed of low concentration partially hydrolyzed polyacrylamide (HPAM) and aluminum citrate (crosslinker). In the work, the conformational changes of LPCs under different conditions were investigated by the methods of membrane filtering under low pressure, dynamic light scattering and core flooding experiments. The results showed that in some conditions the LPCs could be compressed mechanically to 1/158.5 of their original volume because of relatively lower HPAM cross-linking. The hydration property of LPCs was similar to that of normal polymer coils. The deformation of LPCs was more restricted than that of ordinary polymer coils under the flow shear stress or the shift of hydration equilibrium caused in the variation of the electrolyte concentration which is responsible for the effective plugging in the throats of porous media when LPCs are used for deep diverting.

  3. Ground-coupled bore-hole heat exchanger installation: new building in Wattwil; EWS-Anlage, Neubau CAS, Wattwil. Erdwaermesondenanlage

    Energy Technology Data Exchange (ETDEWEB)

    Eichenberger, R.; Kapp, Ch.

    2002-07-01

    This final report for the Swiss Federal Office of Energy (SFOE) presents the results of a monitoring programme carried out on the bore-hole heat exchangers of a geothermal energy system used in a newly constructed commercial building in Wattwil, Switzerland. The geothermal installation is described, which uses two different types of geothermal probes, a normal duplex exchanger and the so-called umbrella probe. The results of the measurement campaigns that were carried out over two winter periods are presented, and the performance of the two types of heat-exchanger are compared. Using correlation diagrams, the two main factors influencing the performance of the probes - temperature and flow - are calculated. The report describes the monitoring configurations used and presents detailed results of the measurements made.

  4. Coil Optimization for HTS Machines

    DEFF Research Database (Denmark)

    Mijatovic, Nenad; Jensen, Bogi Bech; Abrahamsen, Asger Bech

    for different tape parameters Ici, ni and Ci, where Ici, ni and Ci are critical current, n - value and price of the ith tape respectively and i=1, 2, 3…, further optimization with respect to cost vs. HTS losses has been performed. Allowing for different types of HTS tapes in the coils, a guidance to which tape....... The proposed coil design is optimized with respect to minimizing the perpendicular field while still maximizing the amplitude of fundamental space harmonic. This guarantees the lowest HTS loss density and best utilization of expensive HTS material in the field winding of the SM. Additionally, accounting...

  5. Electromagnetic Gun With Commutated Coils

    Science.gov (United States)

    Elliott, David G.

    1991-01-01

    Proposed electromagnetic gun includes electromagnet coil, turns of which commutated in sequence along barrel. Electrical current fed to two armatures by brushes sliding on bus bars in barrel. Interaction between armature currents and magnetic field from coil produces force accelerating armature, which in turn, pushes on projectile. Commutation scheme chosen so magnetic field approximately coincides and moves with cylindrical region defined by armatures. Scheme has disadvantage of complexity, but in return, enables designer to increase driving magnetic field without increasing armature current. Attainable muzzle velocity increased substantially.

  6. INFLUENCE OF REFRIGERANT DISTRIBUTION ON HEAT TRANSFER IN EVAPORATORS

    Institute of Scientific and Technical Information of China (English)

    高原; 田怀璋; 曾艳; 袁秀玲

    2003-01-01

    Objective To prevent the maldistribution of two-phase refrigerant in dry expansion evaporators composed of parallel coils, a distributor is needed to supply refrigerant into the coils. Methods A simplified model of dry expansion evaporator was proposed. The flow and heat transfer in distributing pipes and evaporator coils were simulated with a numerical method. Results The heat flow rate decreases while the refrigerant is distributed unequally to evaporator coils. Conclusion In order to maintain the heat flow rate, larger heat transfer area should be arranged to make up the effect of maldistribution. The larger the discrepancy of mass flow rate is, the more heat transfer area is needed.

  7. [Two Cases of Ruptured Cerebral Aneurysm Complicated with Delayed Coil Protrusion after Coil Embolization].

    Science.gov (United States)

    Furukawa, Takashi; Ogata, Atsushi; Ebashi, Ryo; Takase, Yukinori; Masuoka, Jun; Kawashima, Masatou; Abe, Tatsuya

    2016-07-01

    We report two cases of delayed coil protrusion after coil embolization for ruptured cerebral aneurysms. Case 1:An 82-year-old woman with a subarachnoid hemorrhage due to a ruptured small anterior communicating artery aneurysm underwent successful coil embolization. Eighteen days after the procedure, coil protrusion from the aneurysm into the right anterior cerebral artery was observed without any symptoms. Further coil protrusion did not develop after 28 days. Case 2:A 78-year-old woman with a subarachnoid hemorrhage due to a ruptured small left middle cerebral artery aneurysm underwent successful coil embolization. Twenty days after the procedure, coil protrusion from the aneurysm into the left middle cerebral artery was observed, with a transient ischemic attack. Further coil protrusion did not develop. Both patients recovered with antithrombotic treatment. Even though delayed coil protrusion after coil embolization is rare, it should be recognized as a long-term complication of coil embolization for cerebral aneurysms.

  8. Applicative analysis of Ground-coupled Heat Pump System in Suqian Area%地埋管地源热泵系统在宿迁地区的应用分析

    Institute of Scientific and Technical Information of China (English)

    贾胜辉; 曹亚丽; 顾小雷

    2012-01-01

    The types and work process of ground-coupled heat pump are introduced. The effect of the soil on the ground-coupled heat pump system is analyzed. The application of ground-coupled heat pump system under the Suqian' s climatologic and geological conditions is analyzed. Following a engineering example in Suqian area listed, the reasons why the ground-coupled heat pump system has not been widely used in this area are analyzed. Finally, the suggestions of ground-coupled heat pump system are put forward.%介绍了地埋管地源热泵的系统类型和工作过程,分析了土壤在地埋管地源热泵系统中的作用.结合宿迁地区的气候和地质条件分析地埋管地源热泵系统的适用性并列举工程实例,分析了地埋管地源热泵未普遍应用的原因,最后提出了促进地埋管地源热泵系统在宿迁地区科学发展的建议.

  9. Wuhan Ground Source Heat Pump Engineering Economic Evaluation Based on the Life Cycle%基于全寿命周期的地源热泵工程经济性评价

    Institute of Scientific and Technical Information of China (English)

    付红阳; 陈伟; 张国辉

    2012-01-01

    通过分析我国地源热泵工程的发展现状及国家和武汉地区政策标准,实地调研武汉地区8个地源热泵工程项目相关经济数据,构建武汉地区地源热泵工程经济性评价体系,通过费用构成分析、能耗分析、运行费用分析和环境评价分析对地源热泵工程进行全寿命周期经济性评价,从而为武汉地区乃至全国推广地源热泵工程提供相关依据和建议。%By analyzing development situation of ground source heat pump engineering and policy standards of China and Wuhan province,the paper investigates related economic data of Wuhan eight ground source heat pump engineering,establishes the economic evaluation system of Wuhan ground source heat pump engineering,and do economic evaluates to ground source heat pump engineering of Wuhan from the analysis of expense components,the energy consumption,the operation cost and the environment evaluation,in order to provide relevant basis and suggestions to promote the promote ground source heat pump engineering of Wuhan to the whole nation.

  10. TO DEDUCTION OF MASS FLOW RATE FOR HELICAL HEAT EXCHANGER AT MULTIPLE CROSS-SECTIONS USING CFD

    OpenAIRE

    Surendra Kumar Vishwakarma*, Sanjay Kumbhare, K.K. Thakur

    2016-01-01

    Enhancing the heat transfer by the use of helical coils has been studied and researched by many researchers, because the fluid dynamics inside the pipes of a helical coil heat exchanger offer certain advantages over the straight tubes, shell and tube type heat exchanger, in terms of better heat transfer and mass transfer coefficients. Various configurations of coil structure are possible, and the configuration in which there is a series of vertically stacked helically coiled tubes is the most...

  11. Numerical Simulation of Effect of Disc Plate's Openings on Shell Side Properties of Coiled Heat Exchanger with Convergent-Divergent Tubes%圆盘板开孔对缩放管盘环式换热器壳程性能影响的数值研究

    Institute of Scientific and Technical Information of China (English)

    吴秋华

    2013-01-01

    利用CFD技术对圆盘板上开不同直径孔的缩放管盘环式换热器壳程进行了数值模拟.结果表明,田盘板开孔能在一定程度上改善圆盘板后侧流体的流动状况,且开孔后圆盘与圆环折流板之间的流体压力分布较均匀;开孔直径越大,挟热器的壳程传热系数和压降均越小,综合性能越好;开孔直径不宜过小,适当地开孔才能有效地提高换热器的综合性能.%Making use of CFD,the shell side properties of coiled heat exchanger with convergent — divergent tubes were simulated.The results show that,the disc plate' s opening can improve fluid' s flow condition at disc plate' s rear side and can bring a well-distributed fluid pressure between disc and baffle plate ; and the openings'larger diameter can bring smaller shell side heat transfer coefficient and pressure drop.The opening's proper diameter can benefit the improvement of comprehensive properties of heat exchangers.

  12. Coil Design for High Misalignment Tolerant Inductive Power Transfer System for EV Charging

    Directory of Open Access Journals (Sweden)

    Kafeel Ahmed Kalwar

    2016-11-01

    Full Text Available The inductive power transfer (IPT system for electric vehicle (EV charging has acquired more research interest in its different facets. However, the misalignment tolerance between the charging coil (installed in the ground and pick-up coil (mounted on the car chassis, has been a challenge and fundamental interest in the future market of EVs. This paper proposes a new coil design QDQ (Quad D Quadrature that maintains the high coupling coefficient and efficient power transfer during reasonable misalignment. The QDQ design makes the use of four adjacent circular coils and one square coil, for both charging and pick-up side, to capture the maximum flux at any position. The coil design has been modeled in JMAG software for calculation of inductive parameters using the finite element method (FEM, and its hardware has been tested experimentally at various misaligned positions. The QDQ coils are shown to be capable of achieving good coupling coefficient and high efficiency of the system until the misalignment displacement reaches 50% of the employed coil size.

  13. Application of Construction Technology of Ground Source Heat Pump System in Dongying Software Park Project%土壤源热泵系统施工技术在东营软件大厦工程中的应用

    Institute of Scientific and Technical Information of China (English)

    尚秀委; 刘乐

    2011-01-01

    土壤源热泵是一种利用土壤所储藏的太阳能资源作为冷热源,进行能量转换的供暖制冷空调系统,是清洁的可再生能源的一种新技术.笔者结合工程实际情况,详细介绍了土壤源热泵系统的优点、组成及施工工艺,并且重点介绍了室外地埋管换热器的施工工艺,为今后土壤源热泵空调系统施工质量控制提供了宝贵经验.%The ground source heat pump is a heating and ventilating air conditioning system using the solar energy resources stored by earth as cold and heat sources,and also a new technology of the clean renewable energy.In combination with the project practice,the article expounds in detail the advantages,compositions and construction craft of the ground source heat pump(GSHP)system,and the introduction focuses on the construction craft of the outdoor ground heat exchanger,which provides valuable experience for the construction quality control of the future ground source heat pump air-conditioning system.

  14. West Chester Work Center Solar Space Heating Demonstration Project. Final technical progress report

    Energy Technology Data Exchange (ETDEWEB)

    1979-08-01

    An integrated system is described providing solar energy space heating for a 9982 sq ft, newly built, one-story building. Functionally, the building consists of two sections: an office and a storeroom. The office section is heated by solar-assisted water-to-air heat pump units. The storeroom section is heated by an air-handling unit, containing a water-to-air coil. The system design was based on solar energy providing 62% of the heating load, with the balance to be supplied by heat pump power and a back-up electric boiler. The system includes 1900 active (2112 gross) square feet of flat-plate solar collectors, and a 6000 gallon above-ground indoor storage tank. Freeze protection is provided by a gravity drain-down scheme combined with nitrogen pressurization in a closed circuit.

  15. Transforming the Energy Landscape of a Coiled-Coil Peptide via Point Mutations.

    Science.gov (United States)

    Röder, Konstantin; Wales, David J

    2017-03-14

    We analyze the effect of point mutations on the energy landscape of a coiled-coil peptide, GCN4-pLI, where the native state is a parallel tetrameric configuration formed from two identical dimers. Experimentally, a single mutation, E20S, supports both antiparallel and parallel structures. Here, we analyze the potential energy landscapes of the dimeric units for the parent sequence and four mutants, namely E20S, E20A, E20P, and E20G. Despite sharing characteristic funnels containing the parallel and antiparallel structures, the point mutations change some parts of the landscape quite dramatically, and we predict new intermediate structures and characterize the associated heat capacities. For the mutants we predict that kinked intermediate structures facilitate the transition between parallel and antiparallel morphologies, in contrast to the parent sequence. Furthermore, we predict a change from a multifunnel energy landscape in the E20S mutant to a landscape dominated by an underlying single funnel in the parent sequence, with accompanying heat capacity signatures. Our results imply that changes in the landscape due to mutations might provide useful tools for functional protein design.

  16. 地下水渗流对垂直埋管换热器换热性能影响的实验研究%Experiment on the Factors that Ground Water Flow Influence the Performance of the Heat Exchanger

    Institute of Scientific and Technical Information of China (English)

    冯琛琛; 王沣浩; 张鑫; 姜宇光; 王新轲

    2011-01-01

    地埋管换热器的换热性能是地源热泵空调系统设计的关键问题之一。建立了地源热泵砂箱实验台,实验研究了地下水渗流对地源热泵地埋管换热器换热性能的影响。研究结果表明:地下水渗流可以强化地埋管的换热,且随着渗流速度的增大,强化换热作用越明显。另外,实验结果也表明,u型管周围温度峰值的位置会沿渗流方向向下游偏移,地埋管群布置时应避开该位置,以强化埋管的换热。%To determining the capacity of the ground heat exchanger is one of the key issues of Ground-Source Heat Pump system. In this paper, a Ground-Source Heat Pump experiment rig with sand box was established, and the experiments on the influence of ground water flow rate and the performance of the heat exchanger were conducted. The experimental results show that ground water enhances heat transfer of underground pipe heat exchanger. With the groundwater flow rate increasing, heat transfer enhancement is visible. In addition, the results show that the position of the highest temperature around the U-tube will shift to the lower reaches along the flow direction. Therefore, in order to enhance the heat transfer, multi-pipe arrangement should consider this factor and avoid the position.

  17. Coupled Coils, Magnets and Lenz's Law

    Science.gov (United States)

    Thompson, Frank

    2010-01-01

    Great scientists in the past have experimented with coils and magnets. Here we have a variation where coupling occurs between two coils and the oscillatory motion of two magnets to give somewhat surprising results. (Contains 6 figures and 1 footnote.)

  18. Generalization of Helmholtz coil problem

    Directory of Open Access Journals (Sweden)

    Petković Dejan M.

    2015-01-01

    Full Text Available The primary intent of this work is to propose a simple analytical method for designing coil systems for homogeneous and gradient magnetostatic field generation. Coil system consists of two identical coaxial (regular polygonal current loops. In the space between the loops, there is nearly homogeneous or nearly linear distribution of the magnetic field along the axes depending on the currents' direction. First, we derived a suitable, simple and general expression for the magnetic field along the axes due to a polygonal current loop. We emphasize the importance of the role of this expression for further analysis. The total on-axes magnetic field is the result of superposition of the magnetic fields that each loop generates separately. The proper distance between the loops and the current orientation make the system to become either Helmholtz coil or anti-Helmholtz coil. In this paper we give exact, analytical and general expression for this optimal distance that provides the magnetic field to be homogeneous (linear as much as possible. We based our study on Taylor series expansion of the total magnetic field, demanding that the first contaminating term must be canceled, in both, symmetric and asymmetric case.

  19. Carbon footprint of ground source heat pump system in heating solar greenhouse based on life cycle assessment%日光温室地源热泵供暖碳足迹的生命周期分析

    Institute of Scientific and Technical Information of China (English)

    柴立龙; 马承伟; 刘明池; 王宝驹; 武占会; 许勇

    2014-01-01

    The Chinese solar greenhouse, characterized by east-west orientation, a transparent camber south roof, and a solid north roof and east and west walls, is utilized primarily in horticulture in northern China. This design of greenhouse can keep the sheltering plants from freezing in winter because of the“greenhouse effect”. However, the healthy growing of plants still needs assisted heating especially during winter nights. The coal-fired heating system (CFHs) and the natural gas-fired heating system (GFHs) both have been widely applied to heat greenhouses. However, the conventional fossil energy sources, such as coal and natural gas, are non-renewable and are the major greenhouse gas (GHG) contributors. The overusing of fossil fuel in agricultural production has been directly or indirectly related to the global climate change, environmental pollution, and energy crisis. Therefore, renewable and clean energy, such as solar, geothermal, and shallow geothermal has been increasingly applied for greenhouse heating or cooling across the world. Ground source heat pump (GSHP) technology has dual functions in heating and cooling. It is one of the most rapidly growing green technologies for heating and air-conditioning in recent years. The GSHP application for solar greenhouse heating has proven to have a high primary energy ratio or coefficient of performance (COP) in previously studies. However, the environmental performance of the GSHP in heating solar greenhouse, such as its carbon footprint, is still unknown. Systematic and long-term study of the specific GSHP greenhouse-heating was required to evaluate its carbon footprint based on life cycle assessment (LCA) method. The GSHP in a Chinese solar greenhouse was studied to evaluate its environmental performance in greenhouse heating. The environmental performance of the GSHP was analyzed based on the field test data and the performance analysis models that were developed in this study. According to the study, in a 480 m

  20. Rotor assembly including superconducting magnetic coil

    Energy Technology Data Exchange (ETDEWEB)

    Snitchler, Gregory L. (Shrewsbury, MA); Gamble, Bruce B. (Wellesley, MA); Voccio, John P. (Somerville, MA)

    2003-01-01

    Superconducting coils and methods of manufacture include a superconductor tape wound concentrically about and disposed along an axis of the coil to define an opening having a dimension which gradually decreases, in the direction along the axis, from a first end to a second end of the coil. Each turn of the superconductor tape has a broad surface maintained substantially parallel to the axis of the coil.

  1. Stability test of conduction-cooled LTS/HTS composite coil

    Science.gov (United States)

    Cui, Ying Min; Wang, Yin Shun; Lv, Gang; Pi, Wei

    2016-06-01

    A small LTS/HTS composite coil made of NbTi/Cu and YBCO, with an inner diameter of 80 mm, an outer diameter of 88mm, a height of 50 mm, and an inductance of 5.5 μH, was designed to test its heat disturbance performance in a GM cryocooler. For comparison, a conventional LTS coil of a similar size made of NbTi/Cu wire was also tested. Transport current was applied from 50 A to 700 A at 8 K and 8.5 K, respectively. The two coils’ heat disturbance, minimum quench energy and quench propagation velocity performance were investigated and simulated. The results indicate that the LTS/HTS composite coil shows better thermal stability and is more fit for operation in conductive cryocooler systems compared to LTS coils.

  2. Design of Ground Source Heat Pump Monitoring System Based on MCGS%基于MCGS的地源热泵监控系统的设计

    Institute of Scientific and Technical Information of China (English)

    商家伟; 苏华

    2016-01-01

    A monitoring system is developed for a ground source heat pump system in Chengdu. Equipments are controlled by PLC and monitoring data is transported from PLC to PC. The host PC moni-toring system is developed by MCGS whose functions cover controlling, operation status displaying, data logging and displaying and alarming.%针对成都某别墅地源热泵系统,设计了一个监控系统方案。利用PLC控制空调设备、监测并上传现场数据给上位机。利用MCGS开发上位机监控系统。该监控系统包含设备控制、状态显示、参数采集及显示、报警等功能。

  3. Plasmodium vivax antigen discovery based on alpha-helical coiled coil protein motif

    DEFF Research Database (Denmark)

    Céspedes, Nora; Habel, Catherine; Lopez-Perez, Mary

    2014-01-01

    Protein α-helical coiled coil structures that elicit antibody responses, which block critical functions of medically important microorganisms, represent a means for vaccine development. By using bioinformatics algorithms, a total of 50 antigens with α-helical coiled coil motifs orthologous...

  4. The many types of interhelical ionic interactions in coiled coils - an overview.

    Science.gov (United States)

    Meier, Markus; Stetefeld, Jörg; Burkhard, Peter

    2010-05-01

    Coiled coils represent the most frequent protein oligomerization motif in nature and are involved in many important biological processes. The prototype interhelical ionic interaction for coiled coils described in literature is an i to i+5 ionic interaction from heptad position g to e', but other possible ionic interactions have also been described. Here we use a statistical approach to systematically analyze all high-quality coiled-coil structures in the RCSB protein database for their interhelical ionic interactions. We provide a complete listing of all possible arrangements and analyze the frequency of their occurrence in the primary sequence together with their probability of formation in the quaternary structure of the coiled coils. We show that the classical i to i+5 ionic interaction is indeed characteristic for parallel dimeric and trimeric coiled coils. But we also show that there are many more i to i+2 ionic interactions in parallel tetrameric and pentameric coiled coils, and in antiparallel coiled coils the classical i to i+5 ionic interaction is in none of the oligomerizations states the most frequently observed ionic interaction. We also demonstrate that many ionic interactions involve residues at the core positions that are usually occupied by hydrophobic residues and that such interhelical ionic interactions are a hallmark feature of dimeric coiled coils.

  5. Modeling of an once through helical coil steam generator of a superheated cycle for sizing analysis

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Yeon Sik; Sim, Yoon Sub; Kim, Eui Kwang [Korea Atomic Energy Research Institute, Taejon (Korea, Republic of)

    1997-12-31

    A thermal sizing code, named as HSGSA (Helical coil Steam Generator Sizing Analyzer), for a sodium heated helical coil steam generator is developed for KALIMER (Korea Advanced LIquid MEtal Reactor) design. The theoretical modeling of the shell and tube sides is described and relevant correlations are presented. For assessment of HSGSA, a reference plant design case is compared to the calculational outputs from HSGSA simulation. 9 refs., 6 figs. (Author)

  6. Design of a shielded coil element of a matrix gradient coil

    Science.gov (United States)

    Jia, Feng; Littin, Sebastian; Layton, Kelvin J.; Kroboth, Stefan; Yu, Huijun; Zaitsev, Maxim

    2017-08-01

    The increasing interest in spatial encoding with non-linear magnetic fields has intensified the need for coils that generates such fields. Matrix coils consisting of multiple coil elements appear to offer a high flexibility in generating customized encoding fields and are particularly promising for localized high resolution imaging applications. However, coil elements of existing matrix coils were primarily designed and constructed for better shimming and therefore are not expected to achieve an optimal performance for local spatial encoding. Moreover, eddy current properties of such coil elements were not fully explored. In this work, an optimization problem is formulated based on the requirement of local non-linear encoding and eddy current reduction that results in novel designs of coil elements for an actively-shielded matrix gradient coil. Two metrics are proposed to assess the performance of different coil element designs. The results are analyzed to reveal new insights into coil element design.

  7. Scaffolds, levers, rods and springs: diverse cellular functions of long coiled-coil proteins.

    Science.gov (United States)

    Rose, A; Meier, I

    2004-08-01

    Long alpha-helical coiled-coil proteins are involved in a variety of organizational and regulatory processes in eukaryotic cells. They provide cables and networks in the cyto- and nucleoskeleton, molecular scaffolds that organize membrane systems, motors, levers, rotating arms and possibly springs. A growing number of human diseases are found to be caused by mutations in long coiled-coil proteins. This review summarizes our current understanding of the multifaceted group of long coiled-coil proteins in the cytoskeleton, nucleus, Golgi and cell division apparatus. The biophysical features of coiled-coil domains provide first clues toward their contribution to the diverse protein functions and promise potential future applications in the area of nanotechnology. Combining the power of fully sequenced genomes and structure prediction algorithms, it is now possible to comprehensively summarize and compare the complete inventory of coiled-coil proteins of different organisms.

  8. Repeats in transforming acidic coiled-coil (TACC) genes.

    Science.gov (United States)

    Trivedi, Seema

    2013-06-01

    Transforming acidic coiled-coil proteins (TACC1, 2, and 3) are essential proteins associated with the assembly of spindle microtubules and maintenance of bipolarity. Dysregulation of TACCs is associated with tumorigenesis, but studies of microsatellite instability in TACC genes have not been extensive. Microsatellite or simple sequence repeat instability is known to cause many types of cancer. The present in silico analysis of SSRs in human TACC gene sequences shows the presence of mono- to hexa-nucleotide repeats, with the highest densities found for mono- and di-nucleotide repeats. Density of repeats is higher in introns than in exons. Some of the repeats are present in regulatory regions and retained introns. Human TACC genes show conservation of many repeat classes. Microsatellites in TACC genes could be valuable markers for monitoring numerical chromosomal aberrations and or cancer.

  9. Influences of ground source heat pump operation mode on energy consumption of northern residential heating%地源热泵运行模式对北方住宅供暖能耗的影响

    Institute of Scientific and Technical Information of China (English)

    李永; 句德胜; 李胜会; 郭朝辉

    2016-01-01

    在对一栋满足节能65%设计标准的住宅进行逐时能耗分析的基础上,得出间歇运行的最大热负荷约为连续运行时的3倍,但是连续运行和间歇运行的累计耗热量分别为39.4 kW·h/(m2·a)和33.6 kW·h/(m2·a),建议地源热泵尽量采用连续运行的方式。分析实际项目的装机容量和土壤温度逐年变化情况,所调研的住宅1第一年土壤计算温降为1.81℃,实际温降为1.9℃。提出为了避免土壤温度逐年降低,可采用具有分区补热功能的跨季节蓄热空气源-土壤源复合式系统。%Based on the hourly energy consumption analysis of one residential building which meets the 65% energy-saving design standards,it is concluded that the maximum heat load of the intermittent operation is about 3 times of the continuous operation.How-ever,the accumulated heat consumption of the continuous operation and intermittent oper-ation are 39.4 kW·h/(m2 ·a)and 33.6 kW·h/(m2 ·a),respectively.In view of the a-bove,it is suggested that ground source heat pump uses the mode of continuous operation as far as possible.The installed capacity of the actual proj ect and the change of the soil’s tempera-ture year by year are analyzed and the actual soil’s temperature drop is 1 .9 ℃ of residential building 1 which is researched when the calculation temperature drop is 1 .8 1 ℃.In order to avoid soil’s temperature decreasing year by year,seasonal storage hot air source and ground source hy-brid system which has the function of partition heat supplementary can be used.

  10. Design of Hybrid Ground Source Heat Pump System in WILO China Ltd. New Production Project%北京某工厂地源热泵系统设计

    Institute of Scientific and Technical Information of China (English)

    张杰

    2015-01-01

    本文以北京某工厂混合式地源热泵空调系统为例,对于混合式地源热泵系统的设计、施工、自控作了较详细的论述,供同行借鉴参考。%Taking Uhybrid ground source heat pump system of a factory in Beijing as a example,design,construction,automatic control and operation about the hybrid ground source heat pump system are demonstrated in details for reference.

  11. Elementary analysis Ground source heat pump system design &Discussion on application prospect%地源热泵系统简介及其应用前景探讨

    Institute of Scientific and Technical Information of China (English)

    傅志宝

    2012-01-01

    介绍地源热泵系统设计形式及设计时应注意的问题,简单介绍在具体工程中设计案例及保障措施,探讨地源热泵系统的应用前景。%Introduction of Ground Source Heat Pump system design and the problems should be attention in the design,Simply introduce a engineering design case in the Specific project guarantee measures,The application prospect of Ground Source Heat Pump system.

  12. Application research for ground-source heat pump system applied to large port project%地源热泵空调在大型港口工程中的应用

    Institute of Scientific and Technical Information of China (English)

    张志强

    2009-01-01

    结合工程设计实例,对地源热泵空调在大型港口工程中的应用进行了探讨.对地源热泵和普通中央空调系统的运行费用进行估算和比较.%Combining with practical design example, this paper discusses the application of ground-source heat pump system applied to large port project, and carries out an estimation and comparison of the operating costs between the ground-source heat pump system and common HVAC system.

  13. Second Generation Coil Design of the Nb3Sn low-beta Quadrupole for the High Luminosity LHC

    CERN Document Server

    Izquierdo Bermudez, S; Ballarino, A; Cavanna, E; Bossert, R; Cheng, D; Dietderich, D; Ferracin, P; Ghosh, A; Hagen,P; Holik, E; Perez, J C; Rochepault, E; Schmalzle, J; Todesco, E; Yu, M

    2016-01-01

    As part of the Large Hadron Collider Luminosity upgrade (HiLumi-LHC) program, the US LARP collaboration and CERN are working together to design and build a 150 mm aperture Nb3Sn quadrupole for the LHC interaction regions. A first series of 1.5 m long coils were fabricated and assembled in a first short model. A detailed visual inspection of the coils was carried out to investigate cable dimensional changes during heat treatment and the position of the windings in the coil straight section and in the end region. The analyses allow identifying a set of design changes which, combined with a fine tune of the cable geometry and a field quality optimization, were implemented in a new, second-generation, coil design. In this paper we review the main characteristics of the first generation coils, describe the modification in coil lay-out, and discuss their impact on parts design and magnet analysis.

  14. A numerical study of the effect of groundwater on spiral coil energy piles

    Science.gov (United States)

    Kim, Seong-Kyun; Lee, Youngmin

    2016-04-01

    Numerical simulations were performed to investigate effects of groundwater on the thermal performance of the geothermal energy pile. Energy piles, a part of the closed-loop geothermal heat pump systems, are used to exchange heat between the ground and the heat pump. A heat-carrying fluid circulates the ground through a coiled pipe installed in pile foundations. The COMSOL multiphysics was used as a simulator, which can solve the equations for the temperature and fluid flow in the pipe system, as well as those in the ground. Water temperatures at the pipe outlet after 90-day injection of warm water (30℃) were calculated from following cases: (1) one energy pile installed at the fully saturated medium with regional groundwater flow (100 m/year), (2) one energy pile installed at the partially saturated medium (water table is located 13.5 m below the ground surface) with regional groundwater flow (1,000 m/year), (3) one energy pile installed at the fully saturated medium with no regional groundwater flow, (4) one energy pile installed at the partially saturated medium with no regional groundwater flow, (5), (6), (7) four energy piles (distance between energy piles is 10, 5 ,2 m) installed at the fully saturated medium with regional groundwater flow, and (8), (9), (10) four energy piles installed at the partially saturated medium with regional groundwater flow. The outlet temperature of each case is (1) 28.11℃, (2) 28.84℃, (3) 28.97℃, (4) 29.09℃, (5) 28.19℃ (mean value), (6) 28.24℃ (mean value), (7) 28.33℃ (mean value), (8) 28.84℃ (mean value), (9) 28.90℃ (mean value), and (10) 29.10℃ (mean value), respectively. The thermal power ratio of the energy pile of each case (standard case is case 1) is (1) 0%, (2) -46%, (3) -39%, (4) -52%, (5) -4%, (6) -7%, (7) -12%, (8) -39%, (9) -42%, and (10) -53%, respectively. Numerical results show that the performance of the energy pile installed at the fully saturated medium with regional groundwater flow (case 1

  15. Selection of pipe diameter for ground-source heat pump system%地埋管地源热泵地埋管管径的选取

    Institute of Scientific and Technical Information of China (English)

    张海琳; 余跃进; 胡纯良

    2012-01-01

    详细阐述了地埋管管径对水泵能耗和地埋管换热性能的影响,在地埋管内水流量一定的情况下,选取5种不同管径进行了分析.结果显示,适当增大地埋管管径可减小流体在地埋管内流动时的沿程阻力,降低水泵运行能耗;减小地埋管管径可以增强地埋管内循环水与管壁的对流换热.应该综合考虑,确定最佳管径.%Analyses the influence of pipe diameter on the energy consumption of the water pump and the ground heat exchanger performance in detail. Selects five kinds of different pipe diameter to analyse on the condition of the constant water flow in pipe. The results show that an appropriate increase in pipe diameter can reduce the frictional resistance caused by water flowing in pipe, and reduce the energy consumption of the water pump; a decrease in pipe diameter can enhance the convection heat transfer between the circulating water and the pipe wall. A comprehensive consideration should be given to determining an optimal pipe diameter.

  16. Coil Migration through a Neuroform 3 Stent during Endovascular Coiling. A Case Report.

    LENUS (Irish Health Repository)

    O'Hare, A

    2009-07-29

    Summary: A 43-year-old woman attended for stent assisted coiling. A Neuroform 30 x 4.5 mm stent had been successfully placed over the left periophthalmic aneurysm. During the coiling the first coil migrated through the crowns in the stent, lodging at the MCA bifurcation. We believe that the coil herniated through the overlying stent due to the carotid siphon curvature and the open cell design. Furthermore the distal markers of the stent impeded coil extraction with a MERCI device.

  17. Some aspects of the design of the ITER NBI Active Correction and Compensation Coils

    Energy Technology Data Exchange (ETDEWEB)

    Alonso, Javier, E-mail: javier.alonso@ciemat.es [CIEMAT, Laboratorio Nacional de Fusión, Avda. Complutense 40, 28040 Madrid (Spain); Barrera, Germán; Cabrera, Santiago; Rincón, Esther; Ríos, Luis; Soleto, Alfonso [CIEMAT, Laboratorio Nacional de Fusión, Avda. Complutense 40, 28040 Madrid (Spain); El-Ouazzani, Anass; Graceffa, Joseph; Shah, Darshan; Urbani, Marc [ITER Organization, Route de Vinon-sur-Verdon, CS 90 046, 13067 St Paul Lez Durance Cedex (France); Agarici, Gilbert [Fusion for Energy, Josep Pla 2, Torres Diagonal Litoral B3 – 07/08, 08019 Barcelona (Spain)

    2015-10-15

    Highlights: • Water cooled coil design. • Magnetic shielding of the plasma heating Neutral Beam Injection System. • Active coils for magnetic field compensation. - Abstract: The neutral beam system for ITER consists of two heating and current drive injectors plus a diagnostic neutral beam injector. The proposed physical plant layout allows for a possible third heating injector to be installed later. For correct operation of the beam source, and to avoid deflections of the charged fraction of the beam, the magnetic field along the beam path must be very low. To minimize the stray ITER field in critical areas (ion source, acceleration grids, neutralizer, residual ion dump), a Magnetic Field Reduction System will envelop the beam vessels and the high voltage transmission lines to ion source. This whole system comprises the Passive Magnetic Shield, a set of thick steel plates, and the Active Correction and Compensation Coils, a set of coils carrying currents which depend on the tokamak stray field. This paper describes the status of the coil design, terminals and support structures, as well as a description of the calculations carried out. Most coils are suitable for removal from their final position to be replaced in case of a fault. Conclusions of the chosen design highlight the strategy for the system feasibility.

  18. COMPREHENSIVE EVALUATION OF SOLAR ASSISTED GROUND SOURCE HEAT HUMP%太阳能+地源热泵联合循环项目综合评标

    Institute of Scientific and Technical Information of China (English)

    孙洲阳; 陈武

    2013-01-01

    Selection of heating-ventilation-air conditioning (HVAC) cooling and heating source is a multiattribute problem,involving lots of unmeasurable factors.The fuzzy comprehensive evaluation method transfers qualitative indexes into quantitative indexes utilizing fuzzy membership,and solves the problem very well.Evaluation cases include:(1) solar assisted ground source heat hump central air-conditioning; (2) lithium bromide direct-fired absorption chiller; (3) chiller and fuel boiler; (4) chiller and gas boiler; (5) chiller and electrical boiler.The evaluate results show that the case (1) is the best.%提出一种基于模糊数学的综合评价方法——模糊综合评价法.该方法利用模糊隶属度理论把定性指标合理定量化,把定性评价转化为定量评价.评估方案包括:①太阳能+地源热泵联合循环;②溴化锂吸收式直燃机组;③冷水机组+燃油热水锅炉;④冷水机组+燃气热水锅炉;⑤冷水机组+电锅炉.事实证明,利用模糊综合评价方法得出的最终结果与实际评标结果吻合较好,具有良好的实用价值.

  19. Equilibrium modeling of the TFCX poloidal field coil system

    Energy Technology Data Exchange (ETDEWEB)

    Strickler, D.J.; Miller, J.B.; Rothe, K.E.; Peng, Y.K.M.

    1984-04-01

    The Toroidal Fusion Core Experiment (TFCX) isproposed to be an ignition device with a low safety factor (q approx. = 2.0), rf or rf-assisted startup, long inductive burn pulse (approx. 300 s), and an elongated plasma cross section (kappa = 1.6) with moderate triangularity (delta = 0.3). System trade studies have been carried out to assist in choosing an appropriate candidate for TFCX conceptual design. This report describes an important element in these system studies - the magnetohydrodynamic (MHD) equilibrium modeling of the TFCX poloidal field (PF) coil system and its impact on the choice of machine size. Reference design points for the all-super-conducting toroidal field (TF) coil (TFCX-S) and hybrid (TFCX-H) options are presented that satisfy given PF system criteria, including volt-second requirements during burn, mechanical configuration constraints, maximum field constraints at the superconducting PF coils, and plasma shape parameters. Poloidal coil current waveforms for the TFCX-S and TFCX-H reference designs consistent with the equilibrium requirements of the plasma startup, heating, and burn phases of a typical discharge scenario are calculated. Finally, a possible option for quasi-steady-state operation is discussed.

  20. The design study of the JT-60SU device. No. 3. The superconductor-coils of JT-60SU

    Energy Technology Data Exchange (ETDEWEB)

    Ushigusa, Kenkichi; Mori, Katsuharu; Nakagawa, Syouji [Japan Atomic Energy Research Inst., Naka, Ibaraki (Japan). Naka Fusion Research Establishment] [and others

    1997-03-01

    The superconducting coil systems and the cryogenic system for the JT-60 Super Upgrade (JT-60SU) has been designed. Both Nb{sub 3}Al and NbTi as a superconducting wire material are employed in the toroidal coils (D-shaped 18 coils) to realize a high field magnet with a low cost. Significant reduction of the coil weight (150 tons/coil) without losing the coil rigidity has been achieved by connecting two toroidal coils with shear panels. Validity of this design is confirmed by the detailed structural analysis and thermohydraulic analysis. The poloidal coil system consists of 4 central solenoid coils with (NbTi){sub 3}Sn and 6 outer equilibrium field coils with NbTi. This system has an enough capability to supply the flux of 170Vs to produce a 10MA discharge with 200s of flat-top and to make various plasma configurations. The construction procedure of the poloidal coil system is also established under the constraint of the JT-60 site. Two sets of race-track shaped superconducting coils mounted on the top of the machine is designed to compensate the error field inside the vessel by supplying helical (m=2/n=1) magnetic field. By using cryogenic system with a 36kW of cooling capacity, the total cold weight of around 4000tons can be cooled down to 4.5K within one month, and steady heat load of 6.5kW and transient heat load of 9.0MJ can be removed within 30 minutes of discharge repetition rate. (author)

  1. Performance evaluation of matrix gradient coils.

    Science.gov (United States)

    Jia, Feng; Schultz, Gerrit; Testud, Frederik; Welz, Anna Masako; Weber, Hans; Littin, Sebastian; Yu, Huijun; Hennig, Jürgen; Zaitsev, Maxim

    2016-02-01

    In this paper, we present a new performance measure of a matrix coil (also known as multi-coil) from the perspective of efficient, local, non-linear encoding without explicitly considering target encoding fields. An optimization problem based on a joint optimization for the non-linear encoding fields is formulated. Based on the derived objective function, a figure of merit of a matrix coil is defined, which is a generalization of a previously known resistive figure of merit for traditional gradient coils. A cylindrical matrix coil design with a high number of elements is used to illustrate the proposed performance measure. The results are analyzed to reveal novel features of matrix coil designs, which allowed us to optimize coil parameters, such as number of coil elements. A comparison to a scaled, existing multi-coil is also provided to demonstrate the use of the proposed performance parameter. The assessment of a matrix gradient coil profits from using a single performance parameter that takes the local encoding performance of the coil into account in relation to the dissipated power.

  2. Examples of cost reduction and energy saving by thermal storage heat pump system. Part 5. Control of the flowering season of alstroemeria by using 'ice storage ground cooler'. Chikunetsushiki heat pump system katsuyo ni yoru costdown sho energy jirei no shokai. 5. 'Kori chikunetsushiki chichu reikyaku sochi' ni yori arusutoromeria no kaika jiki wo chosetsu

    Energy Technology Data Exchange (ETDEWEB)

    1999-07-01

    Alstroemeria has a habit to flower by sensing temperature through an organ in rhizome. Since its market price is higher in late fall and early winter, a culture method cooling the ground in summer is in wide use. Although the ground is cooled with an equipment composed of a chiller, ground piping for heat exchange and cold water pump during the whole day, cost reduction is a major problem. To study a heat storage ground cooler, its culture test was made by using a prototype ice storage ground cooler. The test result showed that ground temperature of both test zone and reference zone was constantly 18-20 degrees C during the test period, and both the whole yield and that every class were nearly equivalent between the test and reference zones. The estimation result on the profitability of a full-scale ice storage ground cooler based on the above result showed that this ground cooler probably can reduce annual electric charge by nearly 200,000 yen as compared with a cooler without heat storage. (NEDO)

  3. Examples of cost reduction and energy saving by thermal storage heat pump system. Part 5. Control of the flowering season of alstroemeria by using `ice storage ground cooler`; Chikunetsushiki heat pump system katsuyo ni yoru costdown sho energy jirei no shokai. 5. `Kori chikunetsushiki chichu reikyaku sochi` ni yori arusutoromeria no kaika jiki wo chosetsu

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1999-07-01

    Alstroemeria has a habit to flower by sensing temperature through an organ in rhizome. Since its market price is higher in late fall and early winter, a culture method cooling the ground in summer is in wide use. Although the ground is cooled with an equipment composed of a chiller, ground piping for heat exchange and cold water pump during the whole day, cost reduction is a major problem. To study a heat storage ground cooler, its culture test was made by using a prototype ice storage ground cooler. The test result showed that ground temperature of both test zone and reference zone was constantly 18-20 degrees C during the test period, and both the whole yield and that every class were nearly equivalent between the test and reference zones. The estimation result on the profitability of a full-scale ice storage ground cooler based on the above result showed that this ground cooler probably can reduce annual electric charge by nearly 200,000 yen as compared with a cooler without heat storage. (NEDO)

  4. Quenching in coupled adiabatic coils

    Energy Technology Data Exchange (ETDEWEB)

    Williams, J.E.C.

    1985-03-01

    The prediction of the effects of a quench on stress and temperature is an important aspect of the design of superconducting magnets. Of particular interest, and the exclusive topic of this study, is the prediction of the effects of quenching in coupled adiabatic coils, such as the multi-section windings of a high field NMR spectrometer magnet. The predictive methods used here are based on the measurement of the time of propagation of quench between turns. From this measurement an approximate algorithum for the propagation time is used in a code which solves the linear differential equations for the coil currents and calculates the movement of normal zone boundaries and hence the associated winding resistance.

  5. High performance 3-coil wireless power transfer system for the 512-electrode epiretinal prosthesis.

    Science.gov (United States)

    Zhao, Yu; Nandra, Mandheerej; Yu, Chia-Chen; Tai, Yu-chong

    2012-01-01

    The next-generation retinal prostheses feature high image resolution and chronic implantation. These features demand the delivery of power as high as 100 mW to be wireless and efficient. A common solution is the 2-coil inductive power link, used by current retinal prostheses. This power link tends to include a larger-size extraocular receiver coil coupled to the external transmitter coil, and the receiver coil is connected to the intraocular electrodes through a trans-sclera trans-choroid cable. In the long-term implantation of the device, the cable may cause hypotony (low intraocular pressure) and infection. However, when a 2-coil system is constructed from a small-size intraocular receiver coil, the efficiency drops drastically which may induce over heat dissipation and electromagnetic field exposure. Our previous 2-coil system achieved only 7% power transfer. This paper presents a fully intraocular and highly efficient wireless power transfer system, by introducing another inductive coupling link to bypass the trans-sclera trans-choroid cable. With the specific equivalent load of our customized 512-electrode stimulator, the current 3-coil inductive link was measured to have the overall power transfer efficiency around 36%, with 1-inch separation in saline. The high efficiency will favorably reduce the heat dissipation and electromagnetic field exposure to surrounding human tissues. The effect of the eyeball rotation on the power transfer efficiency was investigated as well. The efficiency can still maintain 14.7% with left and right deflection of 30 degree during normal use. The surgical procedure for the coils' implantation into the porcine eye was also demonstrated.

  6. 热回收地源热泵机组的水温控制%Control of water temperature for ground-source heat pump units with heat recovery

    Institute of Scientific and Technical Information of China (English)

    方徐根; 王建奎; 陆麟; 曾宪纯; 林奕

    2012-01-01

    Presents the indirect control scheme of variable flow rate, I. E. Regulating the temperature of hot water of heat recovery by regulating the water flow rate in ground side to safeguard the steady temperature of chilled water and heat recovery water. Presents the control principle and scheme. With an example project in Hangzhou, verifies the control accuracy of the system, and the result shows that the control effect is favorable.%提出了变流量间接控制方案,即通过调节地源侧水流量间接控制热回收热水温度,以保证冷水和热回收热水温度恒定的方法.给出了控制原理和控制方案.结合杭州某办公楼示范工程,验证了该系统的控制精度,结果表明该系统控制效果良好.

  7. Coiled transmission line pulse generators

    Energy Technology Data Exchange (ETDEWEB)

    McDonald, Kenneth Fox (Columbia, MO)

    2010-11-09

    Methods and apparatus are provided for fabricating and constructing solid dielectric "Coiled Transmission Line" pulse generators in radial or axial coiled geometries. The pour and cure fabrication process enables a wide variety of geometries and form factors. The volume between the conductors is filled with liquid blends of monomers, polymers, oligomers, and/or cross-linkers and dielectric powders; and then cured to form high field strength and high dielectric constant solid dielectric transmission lines that intrinsically produce ideal rectangular high voltage pulses when charged and switched into matched impedance loads. Voltage levels may be increased by Marx and/or Blumlein principles incorporating spark gap or, preferentially, solid state switches (such as optically triggered thyristors) which produce reliable, high repetition rate operation. Moreover, these Marxed pulse generators can be DC charged and do not require additional pulse forming circuitry, pulse forming lines, transformers, or an a high voltage spark gap output switch. The apparatus accommodates a wide range of voltages, impedances, pulse durations, pulse repetition rates, and duty cycles. The resulting mobile or flight platform friendly cylindrical geometric configuration is much more compact, light-weight, and robust than conventional linear geometries, or pulse generators constructed from conventional components. Installing additional circuitry may accommodate optional pulse shape improvements. The Coiled Transmission Lines can also be connected in parallel to decrease the impedance, or in series to increase the pulse length.

  8. Self-correction coil: operation mechanism of self-correction coil

    Energy Technology Data Exchange (ETDEWEB)

    Hosoyama, K.

    1983-06-01

    We discuss here the operation mechanism of self-correction coil with a simple model. At the first stage, for the ideal self-correction coil case we calculate the self-inductance L of self-correction coil, the mutual inductance M between the error field coil and the self-correction coil, and using the model the induced curent in the self-correction coil by the external magnetic error field and induced magnetic field by the self-correction coil. And at the second stage, we extend this calculation method to non-ideal self-correction coil case, there we realize that the wire distribution of self-correction coil is important to get the high enough self-correction effect. For measure of completeness of self-correction effect, we introduce the efficiency eta of self-correction coil by the ratio of induced magnetic field by the self-correction coil and error field. As for the examples, we calculate L, M and eta for two cases; one is a single block approximation of self-correction coil winding and the other is a two block approximation case. By choosing the adequate angles of self-correction coil winding, we can get about 98% efficiency for single block approximation case and 99.8% for two block approximation case. This means that by using the self-correction coil we can improve the field quality about two orders.

  9. 地埋管地源热泵热水供应系统运行性能的影响因素%Influencing factors of operating performance of ground-source heat pump hot water supply systems

    Institute of Scientific and Technical Information of China (English)

    王成勇; 雷俊; 王雁生; 宋月贤

    2012-01-01

    建立了地埋管地源热泵热水供应系统实验平台,研究了环境温度、间歇/连续运行工况、管内循环液流速等对地埋管换热器换热能力的影响,并研究了地埋管换热器周围土壤温度场的变化.结果表明,地埋管地源热泵热水供应系统基本不受环境温度的影响;采用间歇运行,有利于提高地埋管换热器的换热能力;地埋管换热器平均单位井深换热量随管内循环液流速的增大而增大,但当流速增大到一定程度时,其增幅趋于平缓.%Establishes an experimental platform for ground-source heat pump system (GCHP) hot water supply system. Studies the influences of ambient temperature, intermittent or continuous operation mode and flow rate of circulating fluid on the heat exchange efficiency, and studies the variation of soil temperature field around ground heat exchangers. The results show that the GSHP hot water supply system is little influenced by the ambient temperature; intermittent operation mode is conducive to improving the heat exchange capacity of the ground heat exchanger; the heat flow of unit borehole depth of the ground heat exchanger increases along with the fluid flow rate until the fluid flow rate rises to a certain extent when the increasing trends became flat.

  10. Coiled-coil protein composition of 22 proteomes – differences and common themes in subcellular infrastructure and traffic control

    Directory of Open Access Journals (Sweden)

    Meier Iris

    2005-11-01

    Full Text Available Abstract Background Long alpha-helical coiled-coil proteins are involved in diverse organizational and regulatory processes in eukaryotic cells. They provide cables and networks in the cyto- and nucleoskeleton, molecular scaffolds that organize membrane systems and tissues, motors, levers, rotating arms, and possibly springs. Mutations in long coiled-coil proteins have been implemented in a growing number of human diseases. Using the coiled-coil prediction program MultiCoil, we have previously identified all long coiled-coil proteins from the model plant Arabidopsis thaliana and have established a searchable Arabidopsis coiled-coil protein database. Results Here, we have identified all proteins with long coiled-coil domains from 21 additional fully sequenced genomes. Because regions predicted to form coiled-coils interfere with sequence homology determination, we have developed a sequence comparison and clustering strategy based on masking predicted coiled-coil domains. Comparing and grouping all long coiled-coil proteins from 22 genomes, the kingdom-specificity of coiled-coil protein families was determined. At the same time, a number of proteins with unknown function could be grouped with already characterized proteins from other organisms. Conclusion MultiCoil predicts proteins with extended coiled-coil domains (more than 250 amino acids to be largely absent from bacterial genomes, but present in archaea and eukaryotes. The structural maintenance of chromosomes proteins and their relatives are the only long coiled-coil protein family clearly conserved throughout all kingdoms, indicating their ancient nature. Motor proteins, membrane tethering and vesicle transport proteins are the dominant eukaryote-specific long coiled-coil proteins, suggesting that coiled-coil proteins have gained functions in the increasingly complex processes of subcellular infrastructure maintenance and trafficking control of the eukaryotic cell.

  11. Investigation of Horizontal Velocity Fields in Stirred Vessels with Helical Coils by PIV

    Directory of Open Access Journals (Sweden)

    Volker Bliem

    2014-01-01

    Full Text Available Horizontal velocity flow fields were measured by particle image velocimetry for a stirred vessel with baffles and two helical coils for enlargement of heat transfer area. The investigation was carried out in a cylindrical vessel with flat base and two different stirrers (radial-flow Rushton turbine and axial-flow propeller stirrer. Combined velocity plots for flow fields at different locations are presented. It was found that helical coils change the flow pattern significantly. Measurements for the axial-flow Rushton turbine showed a strong deflection by the coils, leading to a mainly tangential flow pattern. Behind baffles large areas of unused heat transfer area were found. First results for the axial-flow propeller reveal an extensive absence of fluid movement in the horizontal plane. Improved design considerations for enhanced heat transfer by more compatible equipment compilation are proposed.

  12. On the Application of Ground Source Heat Pump System in the Airport Hotel%机场宾馆地源热泵系统方案的应用研究

    Institute of Scientific and Technical Information of China (English)

    嵇竑

    2016-01-01

    The construction of the airport hotel needs to consider air conditioning supply and hot water service throughout the year. From the perspective of energy saving transformation, the construction of ground source heat pump system has huge difference with the conventional system in economic and environmental protection terms. From the basic principle of ground source heat pump system, this paper analyzes the advantages and disadvantages of the application of ground source heat pump system in airport hotel to explore the practical application value and broad prospects of the development of ground source heat pump system.%机场宾馆建设需要考虑全年提供冷暖空调、热水服务等,从节能改造的角度出发,建设地源热泵系统对比常规系统在经济方面和环保方面将产生巨大差异.本文从地源热泵系统的基本原理出发,分析研究地源热泵系统在机场宾馆应用中的优势与劣势,并由此探究地源热泵系统发展的实际应用价值和广阔前景.

  13. System Design and Energy Saving Technology Analysis of Ground-source Heat Pump%土壤源热泵系统设计与节能技术分析

    Institute of Scientific and Technical Information of China (English)

    赵金秀; 周红星

    2009-01-01

    The design scheme and characteristics of the ground-source heat pump system were introduced.In addition,the energy consumption during operation periods was briefly analyzed.%主要介绍了土壤源热泵系统的设计及特点,并初步分析了该系统的运行能耗情况.

  14. 太阳能—地源热泵联合循环技术研究%Study on Technologies of Solar Energy and Ground Source Heat Pump Combined Circulation

    Institute of Scientific and Technical Information of China (English)

    孙洲阳; 陈武

    2011-01-01

    太阳能—地源热泵系统联合循环的研究目前还没有形成完备的理论体系,可供应用的基础数据不足,还不能为工程实际应用提供充足的理论依据.本文就太阳能与地源热泵系统联合运行的必要性和可行性进行探讨,提出了相应的技术方案;总结太阳能—地源热泵空调系统的特性,提出太阳能—地源热泵空调系统有待解决的问题,为太阳能—地源热泵联合循环技术在建筑上应用提供参考和借鉴.%Theory system of solar energy combined with ground-source heat pump has not been mature, thereby lack basic data and theory thereunder for engineering application. Necessarity and feasibility of solar energy combined with ground-source heat pump is discussed, bring forward corresponding technique scheme. Character of solar energy combined with ground-source heat pump system is summarized, and bring forward await settle problems, provide reference for architecture application of solar energy combined with ground-source heat pump.

  15. 地源热泵数据监测系统技术评价与应用分析%Technical evaluation and application analysis of ground-source heat pump data monitoring systems

    Institute of Scientific and Technical Information of China (English)

    王华军; 齐承英; 赵冰; 湛文贤

    2012-01-01

    根据当前地源热泵数据监测系统的实施情况,将其分为地下型、地上型、地下+地上型,并进行了技术评价.结合工程实例,介绍了地上型地源热泵数据监测系统的应用情况.提出了尽快完善地源热泵数据监测系统标准体系的建议.%Based on the implementation practice of ground-source heat pump data monitoring systems, classifies the ground-source heat pump data monitoring systems as underground type, overground type and underground plus overground type, and evaluates each of them. With a project example, presents the application of overground type ground-source heat pump data monitoring systems. Proposes to develop ground-source heat pump data monitoring technology standard system as soon as possible.

  16. 浙江地区地源热泵系统适应性研究和设计方法%Adaptability and Design Method for Ground-source Heat Pump System in Zhejiang Province

    Institute of Scientific and Technical Information of China (English)

    唐峰; 胡吉士

    2014-01-01

    Currently, ground-source heat pump technology is widely applied as a renewable energy technology in Zhejiang. From a practical application point of view, there are still many errors in the appli-cable building types and design of the technology. The adaptability of ground-source heat pump system in different building types is analyzed with years of experience in designing ground-source heat pump system. The design methods are presented. The work would provide method and reference for reasonable applica-tion of ground-source heat pump technology in places with hot summer and cold winter.%目前,地源热泵技术作为一项可再生能源技术在浙江地区大力推进。从实际应用看,该技术在适用的建筑类型和设计方面尚存在诸多误区。结合笔者对地源热泵系统多年的设计经验,研究分析了浙江地区地源热泵系统在不同建筑类型中的适应性,并提出了相应的设计方法,可为夏热冬冷地区合理应用地源热泵技术提供参考。

  17. CLOSURE OF HLW TANKS FORMULATION FOR A COOLING COIL GROUT

    Energy Technology Data Exchange (ETDEWEB)

    Harbour, J; Vickie Williams, V; Erich Hansen, E

    2008-05-23

    The Tank Closure and Technology Development Groups are developing a strategy for closing the High Level Waste (HLW) tanks at the Savannah River Site (SRS). Two Type IV tanks, 17 and 20 in the F-Area Tank Farm, have been successfully filled with grout. Type IV tanks at SRS do not contain cooling coils; on the other hand, the majority of the tanks (Type I, II, III and IIIA) do contain cooling coils. The current concept for closing tanks equipped with cooling coils is to pump grout into the cooling coils to prevent pathways for infiltrating water after tank closure. This task addresses the use of grout to fill intact cooling coils present in most of the remaining HLW tanks on Site. The overall task was divided into two phases. Phase 1 focused on the development of a grout formulation (mix design) suitable for filling the HLW tank cooling coils. Phase 2 will be a large-scale demonstration of the filling of simulated cooling coils under field conditions using the cooling coil grout mix design recommended from Phase 1. This report summarizes the results of Phase 1, the development of the cooling coil grout formulation. A grout formulation is recommended for the full scale testing at Clemson Environmental Technology Laboratory (CETL) that is composed by mass of 90% Masterflow (MF) 816 (a commercially available cable grout) and 10% blast furnace slag, with a water to cementitious material (MF 816 + slag) ratio of 0.33. This formulation produces a grout that meets the fresh and cured grout requirements detailed in the Task Technical Plan (2). The grout showed excellent workability under continuous mixing with minimal change in rheology. An alternative formulation using 90% MF 1341 and 10% blast furnace slag with a water to cementitious material ratio of 0.29 is also acceptable and generates less heat per gram than the MF 816 plus slag mix. However this MF 1341 mix has a higher plastic viscosity than the MF 816 mix due to the presence of sand in the MF 1341 cable grout and a

  18. Mosquito coil emissions and health implications.

    Science.gov (United States)

    Liu, Weili; Zhang, Junfeng; Hashim, Jamal H; Jalaludin, Juliana; Hashim, Zailina; Goldstein, Bernard D

    2003-09-01

    Burning mosquito coils indoors generates smoke that can control mosquitoes effectively. This practice is currently used in numerous households in Asia, Africa, and South America. However, the smoke may contain pollutants of health concern. We conducted the present study to characterize the emissions from four common brands of mosquito coils from China and two common brands from Malaysia. We used mass balance equations to determine emission rates of fine particles (particulate matter pollutant concentrations resulting from burning mosquito coils could substantially exceed health-based air quality standards or guidelines. Under the same combustion conditions, the tested Malaysian mosquito coils generated more measured pollutants than did the tested Chinese mosquito coils. We also identified a large suite of volatile organic compounds, including carcinogens and suspected carcinogens, in the coil smoke. In a set of experiments conducted in a room, we examined the size distribution of particulate matter contained in the coil smoke and found that the particles were ultrafine and fine. The findings from the present study suggest that exposure to the smoke of mosquito coils similar to the tested ones can pose significant acute and chronic health risks. For example, burning one mosquito coil would release the same amount of PM(2.5) mass as burning 75-137 cigarettes. The emission of formaldehyde from burning one coil can be as high as that released from burning 51 cigarettes.

  19. A Feasibility Study. Ductless Hydronic Distribution Systems with Fan Coil Delivery

    Energy Technology Data Exchange (ETDEWEB)

    Springer, D. [Alliance for Residential Building Innovation (ARBI), Davis, CA (United States); Dakin, B. [Alliance for Residential Building Innovation (ARBI), Davis, CA (United States); Backman, C. [Alliance for Residential Building Innovation (ARBI), Davis, CA (United States)

    2012-07-01

    The primary objectives of this study are to estimate potential energy savings relative to conventional ducted air distribution, and to identify equipment requirements, costs, and barriers with a focus on ductless hydronic delivery systems that utilize water-to-air terminal units in each zone. Results indicate that annual heating and cooling energy use can be reduced by up to 27% assuming replacement of the conventional 13 SEER heat pump and coil with a similarly rated air-to-water heat pump.

  20. Evaluation of Analytical and Numerical Techniques for Defining the Radius of Influence for an Open-Loop Ground Source Heat Pump System

    Energy Technology Data Exchange (ETDEWEB)

    Freedman, Vicky L.; Mackley, Rob D.; Waichler, Scott R.; Horner, Jacob A.

    2013-09-26

    In an open-loop groundwater heat pump (GHP) sys