WorldWideScience

Sample records for gross floor area

  1. Gross changes in forest area shape the future carbon balance of tropical forests

    Science.gov (United States)

    Li, Wei; Ciais, Philippe; Yue, Chao; Gasser, Thomas; Peng, Shushi; Bastos, Ana

    2018-01-01

    Bookkeeping models are used to estimate land-use and land-cover change (LULCC) carbon fluxes (ELULCC). The uncertainty of bookkeeping models partly arises from data used to define response curves (usually from local data) and their representativeness for application to large regions. Here, we compare biomass recovery curves derived from a recent synthesis of secondary forest plots in Latin America by Poorter et al. (2016) with the curves used previously in bookkeeping models from Houghton (1999) and Hansis et al. (2015). We find that the two latter models overestimate the long-term (100 years) vegetation carbon density of secondary forest by about 25 %. We also use idealized LULCC scenarios combined with these three different response curves to demonstrate the importance of considering gross forest area changes instead of net forest area changes for estimating regional ELULCC. In the illustrative case of a net gain in forest area composed of a large gross loss and a large gross gain occurring during a single year, the initial gross loss has an important legacy effect on ELULCC so that the system can be a net source of CO2 to the atmosphere long after the initial forest area change. We show the existence of critical values of the ratio of gross area change over net area change (γAnetAgross), above which cumulative ELULCC is a net CO2 source rather than a sink for a given time horizon after the initial perturbation. These theoretical critical ratio values derived from simulations of a bookkeeping model are compared with observations from the 30 m resolution Landsat Thematic Mapper data of gross and net forest area change in the Amazon. This allows us to diagnose areas in which current forest gains with a large land turnover will still result in LULCC carbon emissions in 20, 50 and 100 years.

  2. Computational area measurement of orbital floor fractures: Reliability, accuracy and rapidity

    International Nuclear Information System (INIS)

    Schouman, Thomas; Courvoisier, Delphine S.; Imholz, Benoit; Van Issum, Christopher; Scolozzi, Paolo

    2012-01-01

    Objective: To evaluate the reliability, accuracy and rapidity of a specific computational method for assessing the orbital floor fracture area on a CT scan. Method: A computer assessment of the area of the fracture, as well as that of the total orbital floor, was determined on CT scans taken from ten patients. The ratio of the fracture's area to the orbital floor area was also calculated. The test–retest precision of measurement calculations was estimated using the Intraclass Correlation Coefficient (ICC) and Dahlberg's formula to assess the agreement across observers and across measures. The time needed for the complete assessment was also evaluated. Results: The Intraclass Correlation Coefficient across observers was 0.92 [0.85;0.96], and the precision of the measures across observers was 4.9%, according to Dahlberg's formula .The mean time needed to make one measurement was 2 min and 39 s (range, 1 min and 32 s to 4 min and 37 s). Conclusion: This study demonstrated that (1) the area of the orbital floor fracture can be rapidly and reliably assessed by using a specific computer system directly on CT scan images; (2) this method has the potential of being routinely used to standardize the post-traumatic evaluation of orbital fractures

  3. Gross decontamination experiment report

    International Nuclear Information System (INIS)

    Mason, R.; Kinney, K.; Dettorre, J.; Gilbert, V.

    1983-07-01

    A Gross Decontamination Experiment was conducted on various levels and surfaces of the TMI - Unit 2 reactor building in March 1982. The polar crane, D-rings, missile shields, refueling canals, refueling bridges, equipment, and elevations 305' and 347'-6'' were flushed with low pressure water. Additionally, floor surfaces on elevation 305' and floor surfaces and major pieces of equipment on elevation 347'-6'' were sprayed with high pressure water. Selective surfaces were decontaminated with a mechanical scrubber and chemicals. Strippable coating was tested and evaluated on equipment and floor surfaces. The effectiveness, efficiency, and safety of several decontamination techniques were established for the large, complex decontamination effort. Various decontamination equipment was evaluated and its effectiveness was documented. Decontamination training and procedures were documented and evaluated, as were the support system and organization for the experiment

  4. Gross decontamination experiment report

    Energy Technology Data Exchange (ETDEWEB)

    Mason, R.; Kinney, K.; Dettorre, J.; Gilbert, V.

    1983-07-01

    A Gross Decontamination Experiment was conducted on various levels and surfaces of the TMI - Unit 2 reactor building in March 1982. The polar crane, D-rings, missile shields, refueling canals, refueling bridges, equipment, and elevations 305' and 347'-6'' were flushed with low pressure water. Additionally, floor surfaces on elevation 305' and floor surfaces and major pieces of equipment on elevation 347'-6'' were sprayed with high pressure water. Selective surfaces were decontaminated with a mechanical scrubber and chemicals. Strippable coating was tested and evaluated on equipment and floor surfaces. The effectiveness, efficiency, and safety of several decontamination techniques were established for the large, complex decontamination effort. Various decontamination equipment was evaluated and its effectiveness was documented. Decontamination training and procedures were documented and evaluated, as were the support system and organization for the experiment.

  5. Gross changes in forest area shape the future carbon balance of tropical forests

    Directory of Open Access Journals (Sweden)

    W. Li

    2018-01-01

    Full Text Available Bookkeeping models are used to estimate land-use and land-cover change (LULCC carbon fluxes (ELULCC. The uncertainty of bookkeeping models partly arises from data used to define response curves (usually from local data and their representativeness for application to large regions. Here, we compare biomass recovery curves derived from a recent synthesis of secondary forest plots in Latin America by Poorter et al. (2016 with the curves used previously in bookkeeping models from Houghton (1999 and Hansis et al. (2015. We find that the two latter models overestimate the long-term (100 years vegetation carbon density of secondary forest by about 25 %. We also use idealized LULCC scenarios combined with these three different response curves to demonstrate the importance of considering gross forest area changes instead of net forest area changes for estimating regional ELULCC. In the illustrative case of a net gain in forest area composed of a large gross loss and a large gross gain occurring during a single year, the initial gross loss has an important legacy effect on ELULCC so that the system can be a net source of CO2 to the atmosphere long after the initial forest area change. We show the existence of critical values of the ratio of gross area change over net area change (γAnetAgross, above which cumulative ELULCC is a net CO2 source rather than a sink for a given time horizon after the initial perturbation. These theoretical critical ratio values derived from simulations of a bookkeeping model are compared with observations from the 30 m resolution Landsat Thematic Mapper data of gross and net forest area change in the Amazon. This allows us to diagnose areas in which current forest gains with a large land turnover will still result in LULCC carbon emissions in 20, 50 and 100 years.

  6. Gross anatomy of superficial fascia and future localised fat deposit areas of the abdomen in foetus

    Directory of Open Access Journals (Sweden)

    Pramod Kumar

    2013-01-01

    Full Text Available Background: The development and popularity of body contouring procedures such as liposuction and abdominoplasty has renewed interest in the anatomy of the superficial fascia and subcutaneous fat deposits of the abdomen. The study of anatomy of fascia and fetal adipose tissue was proposed as it may be of value in understanding the possible programing of prevention of obesity. Objectives: The present study was undertaken to understand the gross anatomy of superficial fascia of abdomen and to study the gross anatomy of future localized fat deposits (LFDs area of abdomen in fetus. Materials and Methods: Four fetus (two male & two female of four month of intrauterine life were dissected. Attachments & layers of superficial fascia and future subcutaneous fat deposit area of upper and lower abdomen were noted. Results: Superficial fascia of the abdomen was multi layered in mid line and number of layers reduced laterally as in adult. The future abdominal LFD (localized fat deposits area in fetus shows brownish-white blubbary tissue without well-defined adult fat lobules. Conclusion: The attachment and gross anatomy of superficial fascia of the fetus was similar to that in adults. The future LFD areas showed brownish white blubbary tissue with ill-defined fat lobules.

  7. Modeling of methane bubbles released from large sea-floor area: Condition required for methane emission to the atmosphere

    OpenAIRE

    Yamamoto, A.; Yamanaka, Y.; Tajika, E.

    2009-01-01

    Massive methane release from sea-floor sediments due to decomposition of methane hydrate, and thermal decomposition of organic matter by volcanic outgassing, is a potential contributor to global warming. However, the degree of global warming has not been estimated due to uncertainty over the proportion of methane flux from the sea-floor to reach the atmosphere. Massive methane release from a large sea-floor area would result in methane-saturated seawater, thus some methane would reach the atm...

  8. Solving decontaminable flooring problems

    International Nuclear Information System (INIS)

    Anon.

    1989-01-01

    Pennsylvania Power and Light wanted to cover deteriorating concrete in unit 2 of its Susquehanna BWR with a smooth, durable, decontaminable coating. Traditionally, floors in the plant had been coated with epoxy paint, but many of these floors suffered delamination, and failed in three to five years. Painting with epoxy would also interrupt operations for as much as three days while the floor dried, yet critical instruments in some areas had to be monitored at least once per shift. In addition, conventional floor surface preparation produced dust and vibration around sensitive equipment. The solution was a dustless scabbling system for surface preparation, followed by the installation of a high-strength acrylic industrial floor known as Silakal. The work was carried out by Pentek. Silikal bonds to the underlying concrete, so that delamination of the floor will not occur even under severe traffic conditions. Another advantage of this type of flooring is that it cures in one hour, so floor resurfacing has only minimal impact on plant operations. (author)

  9. Development of floor smear sampler (floor radioactive contamination measuring instrument) for nuclear facilities

    International Nuclear Information System (INIS)

    Miyagawa, Minoru; Ito, Haruo; Nozawa, Katsuro; Shinohara, Yotaro; Hashimoto, Hiroshi.

    1980-01-01

    The control of the floor contamination with radioactive substances in nuclear facilities is strictly carried out by smear method, in which the contaminants on floor surfaces are wiped off with filter papers or cloths, and the contamination density on the floor surfaces is measured through their intensity of radioactivity. This wiping work is laborious since it is carried out in leaning-over posture when many samples must be taken in wide floor area. Therefore, to achieve labor saving in this work, an automatic sampler was developed. In the floor smear sampler developed, samples are taken on long band type wiping cloths only by handle operation, and the sample numbers are printed. When many samples are taken in wide floor area, this is especially effective, and the labor saving by 1/3 to 1/2 can be achieved. At present, this sampler is put in practical use in Hamaoka Nuclear Power Station. At the time of trial manufacture, the method of wiping, the mechanisms of wiping, cloth feeding and running, the contact pressure and the number of times of wiping affecting wiping efficiency and the required torque of a motor were examined. The developed sampler is that of constant contact pressure, vibration wiping type, and the rate of sampling is 10 sec per one sample. 100 samples can be taken on one roll of wiping cloth. The results of performance test are reported. (Kako, I.)

  10. Measurement of Gross Alpha and Beta Emission Rates from Ceramic Tiles

    International Nuclear Information System (INIS)

    Wudthicharoonpun, Piyasak; Chankow, Nares

    2007-08-01

    Full text: Ceramic tiles normally used to cover floors and walls contain naturally occurring radioactive elements i.e. potassium-40, uranium, thorium and their daughters from raw materials. Thus, radioactivity was dependent upon source of raw materials and the amount used. The objective of this research was to measure gross alpha and beta emission rates to be used as a database for safety assessment and for selection of rooms to measure radioactive radon-222 gas

  11. Gross beta activity and the concentration of sup(90)Sr in the vegetables of Daejeon area

    Energy Technology Data Exchange (ETDEWEB)

    Lee, J.Y.; Jun, J.S.; Oh, H.P. (Chungnam National Univ., Taejon (Republic of Korea))

    1984-06-01

    The measurement of gross beta activity and the concentration of sup(90)Sr in the vegetables such as Brassica Campestris, Raphanus Sativus and Lactuca Sativa grown in Daejeon area was carried out during the period of April through August 1983. The observed levels of gross beta activity and the concentration of sup(90)Sr in the levels of the vegetables were, on average, 189.2+-51.8pCi/g-ash (2372+-827pCi/kg-fresh) and 44.4+-11.5sup(90)Sr pCi/g-Ca(2.5+-0.5sup(90) pCi/g-ash or 31.6+-8.6 sup(90)Sr pCi/kg-fresh), respectively, while the mean level of the gross beta activity in roots was 158.6+-19.4pCi/g-ash(2121+-899pCi/kg-fresh). On the basis of the ICRP recommendations, an estimative evaluation was made for the concentration of sup(90)Sr in the vegetables, and it was turned out to be far below the permissible level. An attempt was also made to look for any existing difference in the gross beta, activities of the vegetables grown in vinyl house and in open field, taking seasonal variation of airborne radioactivity into account for normalizing the activity deposited during the course of discrepant farming period.

  12. High-capacity transport, floor area ratio and its relationship with urbanization of metropolitan areas

    Energy Technology Data Exchange (ETDEWEB)

    Carvalho da Costa, B.L. de; Carvalho da Costa, F.B. de

    2016-07-01

    Most of the world’s population lives in urban areas (54%). Near 42% of the global urban population live in cities with more than 1 million inhabitants, where problems associated with urban sprawl such as informal settlement, social-economic changes, environmental degradation and deficient high-capacity transport (HCT) systems are common. Meanwhile, urbanization and its associated transportation infrastructure define the relationship between city and countryside, between the city’s inner core and the periphery, between the citizen and his right to move. This article discusses and presents an overview about the relationship between the planning and extension of HCT systems and urban planning, (in the figure of the floor-area ratio - FAR- prescribed in regulations). The methodological approach consists of drawing a conceptual framework and studying 33 different cities of metropolitan areas on five continents. It’s noticed that areas in cities with a high construction potential but with an insufficient HCT negatively influence in urban mobility and hence the right to the city. We consider right to the city the various social and fundamental rights that, among others, includes the right to public transportation. Therefore there’s a real need of an integrated approach of community participation, FAR distribution, urban planning and transportation planning and so that urbanization, inevitable these days, takes place in a fair and harmonious way. (Author)

  13. Flooring choices for newborn ICUs.

    Science.gov (United States)

    White, R D

    2007-12-01

    Floors are a major element of newborn intensive care unit (NICU) construction. They provide visual cues, sound control, and with certain materials, some degree of physical comfort for workers. Flooring materials may entail a significant cost for installation and upkeep and can have substantial ecological impact, both in the choice of the flooring itself, as well as the substances used to clean it. In this article the important aspects to consider for each factor are explored and recommendations are offered for appropriate choices in various NICU areas.

  14. Effects of ventilation rate per person and per floor area on perceived air quality, sick building syndrome symptoms, and decision-making.

    Science.gov (United States)

    Maddalena, R; Mendell, M J; Eliseeva, K; Chan, W R; Sullivan, D P; Russell, M; Satish, U; Fisk, W J

    2015-08-01

    Ventilation rates (VRs) in buildings must adequately control indoor levels of pollutants; however, VRs are constrained by the energy costs. Experiments in a simulated office assessed the effects of VR per occupant on perceived air quality (PAQ), Sick Building Syndrome (SBS) symptoms, and decision-making performance. A parallel set of experiments assessed the effects of VR per unit floor area on the same outcomes. Sixteen blinded healthy young adult subjects participated in each study. Each exposure lasted four hours and each subject experienced two conditions in a within-subject study design. The order of presentation of test conditions, day of testing, and gender were balanced. Temperature, relative humidity, VRs, and concentrations of pollutants were monitored. Online surveys assessed PAQ and SBS symptoms and a validated computer-based tool measured decision-making performance. Neither changing the VR per person nor changing the VR per floor area, had consistent statistically significant effects on PAQ or SBS symptoms. However, reductions in either occupant-based VR or floor-area-based VR had a significant and independent negative impact on most decision-making measures. These results indicate that the changes in VR employed in the study influence performance of healthy young adults even when PAQ and SBS symptoms are unaffected. The study results indicate the importance of avoiding low VRs per person and low VRs per floor area to minimize decrements in cognitive performance. © 2014 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  15. Gross alpha and gross beta determination in surface and groundwater water by liquid scintillation counting (LSC)

    International Nuclear Information System (INIS)

    Faria, Ligia S.; Moreira, Rubens M.

    2013-01-01

    The present study has used 40 samples of groundwater and surface water collected at four different sites along the period of one year in Brumadinho and Nova Lima, two municipalities in the State of Minas Gerais, Brazil, as part of a more extensive study aiming at determination of the natural radioactivity in the water used for domestic use. These two sites are inside an Environmental Protection Area is located in a region of very intensive iron ore exploration. In addition of mineral resources, the region has a geological characteristic that includes quartzitic conglomerates associated with uranium. Radioactivity levels were determined via liquid scintillation counting (LSC), a fast and high counting efficiency method that can be advantageously employed to determine gross alpha and gross beta activity in liquid samples. Previously to gross alpha and gross beta counting the samples were acidified with concentrated HNO 3 in the field. The technique involved a pre-concentration of the sample to obtain a low detection limit. Specific details of the employed methodology are commented. The results showed that concentrations of gross alpha natural activity and gross beta values ranged from less than the detection limit of the equipment (0.03 Bq.L -1 ) to 0.275 ± 0.05 Bq.L -1 for gross alpha. As regards gross beta, all samples were below the limit of detection. (author)

  16. Pelvic floor and sexual male dysfunction

    Directory of Open Access Journals (Sweden)

    Antonella Pischedda

    2013-04-01

    Full Text Available The pelvic floor is a complex multifunctional structure that corresponds to the genito- urinary-anal area and consists of muscle and connective tissue. It supports the urinary, fecal, sexual and reproductive functions and pelvic statics. The symptoms caused by pelvic floor dysfunction often affect the quality of life of those who are afflicted, worsening significantly more aspects of daily life. In fact, in addition to providing support to the pelvic organs, the deep floor muscles support urinary continence and intestinal emptying whereas the superficial floor muscles are involved in the mechanism of erection and ejaculation. So, conditions of muscle hypotonia or hypertonicity may affect the efficiency of the pelvic floor, altering both the functionality of the deep and superficial floor muscles. In this evolution of knowledge it is possible imagine how the rehabilitation techniques of pelvic floor muscles, if altered and able to support a voiding or evacuative or sexual dysfunction, may have a role in improving the health and the quality of life.

  17. The gross beta activity and the concentration of sup(90)Sr in the vegetables of Daejeon area

    International Nuclear Information System (INIS)

    Lee, J.Y.; Jun, J.S.; Oh, H.P.

    1984-01-01

    The measurement of gross beta activity and the concentration of sup(90)Sr in the vegetables such as Brassica Campestris, Raphanus Sativus and Lactuca Sativa grown in Daejeon area was carried out during the period of April through August 1983. The observed levels of gross beta activity and the concentration of sup(90)Sr in the levels of the vegetables were, on average, 189.2+-51.8pCi/g-ash (2372+-827pCi/kg-fresh) and 44.4+-11.5sup(90)Sr pCi/g-Ca(2.5+-0.5sup(90) pCi/g-ash or 31.6+-8.6 sup(90)Sr pCi/kg-fresh), respectively, while the mean level of the gross beta activity in roots was 158.6+-19.4pCi/g-ash(2121+-899pCi/kg-fresh). On the basis of the ICRP recommendations, an estimative evaluation was made for the concentration of sup(90)Sr in the vegetables, and it was turned out to be far below the permissible level. An attempt was also made to look for any existing difference in the gross beta, activities of the vegetables grown in vinyl house and in open field, taking seasonal variation of airborne radioactivity into account for normalizing the activity deposited during the course of discrepant farming period. (Author)

  18. Motor cortical representation of the pelvic floor muscles.

    Science.gov (United States)

    Schrum, A; Wolff, S; van der Horst, C; Kuhtz-Buschbeck, J P

    2011-07-01

    Pelvic floor muscle training involves rhythmical voluntary contractions of the external urethral sphincter and ancillary pelvic floor muscles. The representation of these muscles in the motor cortex has not been located precisely and unambiguously. We used functional magnetic resonance imaging to determine brain activity during slow and fast pelvic floor contractions. Cerebral responses were recorded in 17 healthy male volunteers, 21 to 47 years old, with normal bladder control. Functional magnetic resonance imaging was performed during metronome paced slow (0.25 Hertz) and fast (0.7 Hertz) contractions of the pelvic floor that mimicked the interruption of voiding. To study the somatotopy of the cortical representations, flexion-extension movements of the right toes were performed as a control task. Functional magnetic resonance imaging during pelvic floor contractions detected activity of the supplementary motor area in the medial wall and of the midcingulate cortex, insula, posterior parietal cortex, putamen, thalamus, cerebellar vermis and upper ventral pons. There were no significant differences in activation between slow and fast contractions. Toe movements involved significantly stronger activity of the paracentral lobule (ie the medial primary motor cortex) than did the pelvic floor contractions. Otherwise the areas active during pelvic floor and leg muscle contractions overlapped considerably. The motor cortical representation of pelvic floor muscles is located mostly in the supplementary motor area. It extends further ventrally and anteriorly than the representation of distal leg muscles. Copyright © 2011 American Urological Association Education and Research, Inc. Published by Elsevier Inc. All rights reserved.

  19. Influence of crosstalk phenomenon on the measurement of gross alpha and gross beta radioactivity in drinking water

    International Nuclear Information System (INIS)

    Gerilemandahu; Haribala; Xu Xiao; Shen Na; Sai Wenga; Bai Guilin; Wang Chengguo

    2014-01-01

    Objective: To study the influence of crosstalk phenomenon on the measurement of gross radioactivity in drinking water. Methods: The gross activity in different standard materials with different thickness and area was measured using national standard method. Results: There was no obvious change in crosstalk factor with the increase of "2"4"1Am powder amount in the measurement, whereas the larger amount of uranium used might lead to larger crosstalk factor. The different measurement channels resulted in different crosstalk factors. The influence of beta radioactivity on alpha radioactivity measurement was significant. On the contrary, the alpha-to-beta crosstalk factor was negligible. The area of sample plate imposed no significant influence on crosstalk factor. Conclusions: The gross beta activity can be corrected to decrease the influence of alpha radioactivity using powder standard samples, when simultaneous alpha and beta counting mode is applied in measurement grass radioactivity in drinking water. (authors)

  20. Floor interaction

    DEFF Research Database (Denmark)

    Petersen, Marianne Graves; Krogh, Peter; Ludvigsen, Martin

    2005-01-01

    Within architecture, there is a long tradition of careful design of floors. The design has been concerned with both decorating floors and designing floors to carry information. Ubiquitous computing technology offers new opportunities for designing interactive floors. This paper presents three...... different interactive floor concepts. Through an urban perspective it draws upon the experiences of floors in architecture, and provides a set of design issues for designing interactive floors....

  1. Determination of gross alpha and gross beta in soil around repository facility at Bukit Kledang, Perak, Malaysia

    Science.gov (United States)

    Adziz, Mohd Izwan Abdul; Siong, Khoo Kok

    2018-04-01

    Recently, the Long Term Storage Facility (LTSF) in Bukit Kledang, Perak, Malaysia, has been upgraded to repository facility upon the completion of decontamination and decommissioning (D&D) process. Thorium waste and contaminated material that may contain some minor amounts of thorium hydroxide were disposed in this facility. This study is conducted to determine the concentrations of gross alpha and gross beta radioactivities in soil samples collected around the repository facility. A total of 12 soil samples were collected consisting 10 samples from around the facility and 2 samples from selected residential area near the facility. In addition, the respective dose rates were measured 5 cm and 1 m above the ground by using survey meter with Geiger Muller (GM) detector and Sodium Iodide (NaI) detector. Soil samples were collected using hand auger and then were taken back to the laboratory for further analysis. Samples were cleaned, dried, pulverized and sieved prior to analysis. Gross alpha and gross beta activity measurements were carried out using gas flow proportional counter, Canberra Series 5 XLB - Automatic Low Background Alpha and Beta Counting System. The obtained results show that, the gross alpha and gross beta activity concentration ranged from 1.55 to 5.34 Bq/g with a mean value of 3.47 ± 0.09 Bq/g and 1.64 to 5.78 Bq/g with a mean value of 3.49 ± 0.09 Bq/g, respectively. These results can be used as an additional data to represent terrestrial radioactivity baseline data for Malaysia environment. This estimation will also serve as baseline for detection of any future related activities of contamination especially around the repository facility area.

  2. Measurement of gross alpha, gross beta, radon and radium activity concentrations in aqueous samples using liquid scintillation technique

    International Nuclear Information System (INIS)

    Zaini Hamzah; Ahmad Saat; Masitah Alias; Siti Afiqah Abdul Rahman; Mohamed Kasim; Abdul Kadir Ishak

    2011-01-01

    Recently, Malaysia has taken a positive step toward providing a better water quality by introducing more water quality parameters into its Water Quality Standard. With regard to the natural radionuclides that may present in the water, 3 parameters were introduced that is gross alpha, gross beta and radium which need to be measured and cannot exceed 0.1, 1.0 and 1.0 Bq/ L respectively. This study was conducted to develop a more practical method in measuring these parameters in aqueous environmental samples. Besides having a lot of former tin mining areas, some part of Malaysia is located on the granitic rock which also contributes to a certain extent the amount of natural radionuclides such as uranium and thorium. For all we know these two radionuclides are the origin of other radionuclides being produced from their decay series. The State of Kelantan was chosen as the study area, where the water samples were collected from various part of the Kelantan River. 25 liters of samples were collected, acidify to pH 2 and filtered before the analysis. Measurement of these parameters was done using liquid scintillation counter (LSC). The LSC was set up to the optimum discriminator level and counting was done using alpha-beta mode. The results show that gross alpha and beta can be measured using scintillation cocktail and radium and radon using extraction method. The results for gross alpha, gross beta, 222 Ra and 226 Ra are 0.39-6.42, 0.66-16.18, 0.40-4.65 and 0.05-0.56 Bq/ L. MDA for gross alpha, gross beta and radium is 0.03, 0.08 and 0.00035 Bq/ L respectively. (Author)

  3. A novel & affordable interactive floor for educational applications

    DEFF Research Database (Denmark)

    Boisen, Ulrik; Hansen, Anders Juul; Knudsen, Lars

    2011-01-01

    This article examines two research areas: How interactive floors can be used beneficially in an educational context, and how an interactive floor can be created which is mobile and relatively inexpensive....

  4. Global floor planning approach for VLSI design

    International Nuclear Information System (INIS)

    LaPotin, D.P.

    1986-01-01

    Within a hierarchical design environment, initial decisions regarding the partitioning and choice of module attributes greatly impact the quality of the resulting IC in terms of area and electrical performance. This dissertation presents a global floor-planning approach which allows designers to quickly explore layout issues during the initial stages of the IC design process. In contrast to previous efforts, which address the floor-planning problem from a strict module placement point of view, this approach considers floor-planning from an area planning point of view. The approach is based upon a combined min-cut and slicing paradigm, which ensures routability. To provide flexibility, modules may be specified as having a number of possible dimensions and orientations, and I/O pads as well as layout constraints are considered. A slicing-tree representation is employed, upon which a sequence of traversal operations are applied in order to obtain an area efficient layout. An in-place partitioning technique, which provides an improvement over previous min-cut and slicing-based efforts, is discussed. Global routing and module I/O pin assignment are provided for floor-plan evaluation purposes. A computer program, called Mason, has been developed which efficiently implements the approach and provides an interactive environment for designers to perform floor-planning. Performance of this program is illustrated via several industrial examples

  5. Perceived floor slipperiness and floor roughness in a gait experiment.

    Science.gov (United States)

    Yu, Ruifeng; Li, Kai Way

    2015-01-01

    Slips and falls contribute to occupational injuries and fatalities globally. Both floor slipperiness and floor roughness affect the occurrence of slipping and falling. Investigations on fall-related phenomena are important for the safety and health of workers. The purposes of this study were to: compare the perceived floor slipperiness before and after walking on the floor; compare the perceived floor slipperiness with and without shoes for males and females; discuss the perceived floor roughness based on barefoot walking; and establish regression models to describe the relationship between perceived floor slipperiness and actual friction of the floors. Male and female subjects walked on 3 m walkways with or without shoes. The perceived floor slipperiness ratings both before and after their walk were collected. The perceived floor slipperiness both before and after walking were significantly affected by both floor and surface conditions. Gender, floor, surface, and footwear conditions were all significant factors affecting the adjustment of perceived floor slipperiness. The subjects made more adjustment on perceived floor slipperiness rating when they had shoes on than when they were barefooted. Regression models were established to describe the relationship between perceived floor slipperiness and floor coefficient of friction. These models may be used to estimate perceived floor slipperiness, or in reverse, the coefficient of friction of the floor, so as to prevent slipping and falling in workplaces.

  6. WOODEN FLOORING – BETWEEN PRESENT AND FUTURE

    Directory of Open Access Journals (Sweden)

    Ivan CISMARU

    2015-06-01

    Full Text Available The paper aims at presenting a systematization of the wood floors, both in terms of the areas of application, and in terms of the fastening solutions and structures in constructions. In this respect, an extensive bibliographic research was achieved, on the researchers’ preoccupations. Starting from the current situation and forecasting the future, from the point of view of the chances held by wooden flooring, in competition with other types of materials, we dare say the wooden flooring or the wood in combination with other materials are not likely to be eliminated from the “civil-engineering market”. The wood floors are likely to develop as an application, especially in the area of the “special floors”, specific to the indoor sports or social halls; and even for some industrial sectors, with strict operating conditions (elasticity, thermal insulation, soundproofing that cannot be provided by other types of materials or structures. Starting from this last observation, the paper also aims at submitting current opinions with respect to this type of floors, both in the light of the current databases and in the light of the future researches, to this end

  7. Effect of slatted and solid floors and permeability of floors in pig houses on environment, animal welfare and health and food safety: a review of literature

    NARCIS (Netherlands)

    Vermeij, I.; Enting, J.; Spoolder, H.A.M.

    2009-01-01

    An integrated approach can improve understanding of floor performance. Not only gap width or percentage of slatted floor is important, but a minimum percentage of permeability of the total floor area appears to be decisive

  8. Measurement of Gross Alpha and Gross Beta Radioactivity of River Yobe, North Eastern Nigeria

    International Nuclear Information System (INIS)

    Abba, H. T.; Sadiq, U.; Adeyemo, D. J.

    2013-01-01

    Measurement of the gross alpha and gross beta radioactivity of River Yobe has been carried out. Fifteen samples of the river water were collected from the farming, fishing, domestic/livestock and control areas along the river and were analyzed using desktop alpha/beta (MPC 2000- DP) counting system. The count results show the average alpha activities in farming, fishing, domestic/livestock and control areas are 0.207±0.082, 0.257±0.13, 0.437±0.315 and 0.237±0.10 Bq L -1 , respectively. The average beta activities in the four areas are 0.813±0.122, 0.308±0.0145, 0.563±0.230 and 0.225±0.0096 Bq L -1 , respectively. The overall results show that the alpha and beta activities in the four areas are far below the practical screening level of radioactivity in drinking water of 0.5 Bq L -1 for alpha and 1 Bq L -1 for beta recommended by CEC-FAO and WHO and therefore may not pose any serious detrimental health side-effects to the public users of the river.

  9. Sea-floor morphology and sedimentary environments in southern Narragansett Bay, Rhode Island

    Science.gov (United States)

    McMullen, Katherine Y.; Poppe, Lawrence J.; Blackwood, Dann S.; Nardi, Matthew J.; Andring, Matthew A.

    2015-09-09

    Multibeam echosounder data collected by the National Oceanic and Atmospheric Administration along with sediment samples and still and video photography of the sea floor collected by the U.S. Geological Survey were used to interpret sea-floor features and sedimentary environments in southern Narragansett Bay, Rhode Island, as part of a long-term effort to map the sea floor along the northeastern coast of the United States. Sea-floor features include rocky areas and scour depressions in high-energy environments characterized by erosion or nondeposition, and sand waves and megaripples in environments characterized by coarse-grained bedload transport. Two shipwrecks are also located in the study area. Much of the sea floor is relatively featureless within the resolution of the multibeam data; sedimentary environments in these areas are characterized by processes associated with sorting and reworking. This report releases bathymetric data from the multibeam echosounder, grain-size analyses of sediment samples, and photographs of the sea floor and interpretations of the sea-floor features and sedimentary environments. It provides base maps that can be used for resource management and studies of topics such as benthic ecology, contaminant inventories, and sediment transport.

  10. Gross motor skill development of 5-year-old Kindergarten children in Myanmar.

    Science.gov (United States)

    Aye, Thanda; Oo, Khin Saw; Khin, Myo Thuzar; Kuramoto-Ahuja, Tsugumi; Maruyama, Hitoshi

    2017-10-01

    [Purpose] The purpose of this study was to examine the gross motor skill development of 5-year-old Kindergarten children in Myanmar. [Subjects and Methods] Total 472 healthy Kindergarten children (237 males, 235 females) of 2016-2017 academic year from four schools in urban area and four schools in rural area of Myanmar were recruited. The gross motor skill development of all subjects was assessed with the test of gross motor development second edition (TGMD-2). All subjects performed two trials for each gross motor skill and the performance was video recorded and scored. The assessment procedures were done according to the standardized guidelines of TGMD-2. [Results] The majority of subjects had average level of gross motor skill rank. The significant differences were found on the run and gallop of locomotor skills and the most of object control skills except the catch between males and females. The significant differences were also found between subjects from urban and rural areas. [Conclusion] Gross motor skill development of 5-year-old Kindergarten children in Myanmar had gender-based and region-based differences on both locomotor and object control skills. This study added a valuable information to the establishment of a normative reference of Kindergarten aged children for future studies.

  11. Potential heat savings during ongoing renovation of buildings until 2050

    DEFF Research Database (Denmark)

    Wittchen, Kim Bjarne; Kragh, Jesper; Aggerholm, Søren

    information about insulation level, building component areas, i.e. roofs, external walls, floors and windows/doors, per unit area (gross heated floor area). The report is made for the Danish Energy Agency and targeted the Danish building industry, the agency itself and political decision makers in preparation...

  12. SUSTAINABLE TRAILER FLOORING

    Directory of Open Access Journals (Sweden)

    John Lu

    2009-05-01

    Full Text Available Different trailer flooring materials, including wood-based, aluminum, steel, and synthetic plastic floors, were evaluated in accordance with their durability and sustainability to our natural environment. Wood-based trailer flooring is an eco-friendly product. It is the most sustainable trailer flooring material compared with fossil fuel-intensive steel, aluminum, and plastics. It is renewable and recyclable. Oak, hard maple, and apitong are strong and durable hardwood species that are currently extensively used for trailer flooring. For manufacture, wood-based flooring is higher in energy efficiency and lower in carbon emission than steel, aluminum and plastics. Moreover, wood per se is a natural product that sequesters carbon. Accordingly, using more wood-based trailer flooring is effective to reduce global warming.

  13. Gross National Happiness

    DEFF Research Database (Denmark)

    Giri, Krishna Prasad; Kjær-Rasmussen, Lone Krogh

    This paper investigates practices related to the ideology of infusing Gross National Happiness (GNH) into school curriculum, the effectiveness of the meditation and mind training and the implication of GNH for school environment. It also explores how GNH ambience has been managed and practiced...... of Gross National Happiness and Educating for Gross National happiness....

  14. Changes in conifer and deciduous forest foliar and forest floor chemistry and basal area tree growth across a nitrogen (N) deposition gradient in the northeastern US

    Science.gov (United States)

    Johnny L. Boggs; Steven G. McNulty; Linda H. Pardo

    2007-01-01

    We evaluated foliar and forest floor chemistry across a gradient of N deposition in the Northeast at 11 red spruce (Picea rubens Sarg.) sites in 1987/1988 and foliar and forest floor chemistry and basal area growth at six paired spruce and deciduous sites in 1999. The six red spruce plots were a subset of the original 1987/1988 spruce sites. In 1999...

  15. A Method Validation for Determination of Gross Alpha and Gross Beta in Water Sample Using Low Background Gross Alpha/ Beta Counting System

    International Nuclear Information System (INIS)

    Zal Uyun Wan Mahmood; Norfaizal Mohamed; Nita Salina Abu Bakar

    2016-01-01

    Method validation (MV) for the measurement of gross alpha and gross beta activity in water (drinking, mineral and environmental) samples using Low Background Gross Alpha/ Beta Counting System was performed to characterize precision, accuracy and reliable results. The main objective of this assignment is to ensure that both the instrument and method always good performed and resulting accuracy and reliable results. Generally, almost the results of estimated RSD, z-score and U_s_c_o_r_e were reliable which are recorded as ≤30 %, less than 2 and less than 1.5, respectively. Minimum Detected Activity (MDA) was estimated based on the counting time of 100 minutes and present background counting value of gross alpha (0.01 - 0.35 cpm) and gross beta (0.50 - 2.18 cpm). Estimated Detection Limit (DL) was 0.1 Bq/ L for gross alpha and 0.2 Bq/ L for gross beta and expended uncertainty was relatively small of 9.77 % for gross alpha and 10.57 % for gross beta. Align with that, background counting for gross alpha and gross beta was ranged of 0.01 - 0.35 cpm and 0.50 - 2.18 cpm, respectively. While, sample volume was set at minimum of 500 mL and maximum of 2000 mL. These proven the accuracy and precision result that are generated from developed method/ technique is satisfactory and method is recommended to be used. Therefore, it can be concluded that the MV found no doubtful on the ability of the developed method. The test result showed the method is suitable for all types of water samples which are contained several radionuclides and elements as well as any impurities that interfere the measurement analysis of gross alpha and gross beta. (author)

  16. Sea-floor geology in northwestern Block Island Sound, Rhode Island

    Science.gov (United States)

    McMullen, Katherine Y.; Poppe, Lawrence J.; Ackerman, Seth D.; Blackwood, Dann S.; Woods, D.A.

    2014-01-01

    Multibeam-echosounder and sidescan-sonar data, collected by the National Oceanic and Atmospheric Administration in a 69-square-kilometer area of northwestern Block Island Sound, are used with sediment samples, and still and video photography of the sea floor, collected by the U.S. Geological Survey at 43 stations within this area, to interpret the sea-floor features and sedimentary environments. Features on the sea floor include boulders, sand waves, scour depressions, modern marine sediments, and trawl marks. Boulders, which are often several meters wide, are found in patches in the shallower depths and tend to be overgrown with sessile flora and fauna. They are lag deposits of winnowed glacial drift, and reflect high-energy environments characterized by processes associated with erosion and nondeposition. Sand waves and megaripples tend to have crests that either trend parallel to shore with 20- to 50-meter (m) wavelengths or trend perpendicular to shore with several-hundred-meter wavelengths. The sand waves reflect sediment transport directions perpendicular to shore by waves, and parallel to shore by tidal or wind-driven currents, respectively. Scour depressions, which are about 0.5 m lower than the surrounding sea floor, have floors of gravel and coarser sand than bounding modern marine sediments. These scour depressions, which are conspicuous in the sidescan-sonar data because of their more highly reflective coarser sediment floors, are likely formed by storm-generated, seaward-flowing currents and maintained by the turbulence in bottom currents caused by their coarse sediments. Areas of the sea floor with modern marine sediments tend to be relatively flat to current-rippled and sandy.

  17. Floors: Selection and Maintenance.

    Science.gov (United States)

    Berkeley, Bernard

    Flooring for institutional, commercial, and industrial use is described with regard to its selection, care, and maintenance. The following flooring and subflooring material categories are discussed--(1) resilient floor coverings, (2) carpeting, (3) masonry floors, (4) wood floors, and (5) "formed-in-place floors". The properties, problems,…

  18. Development of remote operated floor contamination monitor

    International Nuclear Information System (INIS)

    Sreekumar, K.; Gangamohan, M.; Kannan, R.K.; Rajan, S.

    2005-01-01

    Contamination check of floors and walkways in and around Reactor building areas forms an integral part of Radiation Protection Program in Power Stations. Though random swipe check method is adopted for the detection of loose contamination, this method has the disadvantage of leaving the fixed contamination and hotspots undetected. Hence, scanning the area with a sensitive detector, held close to the surface provides positive means for the detection of contamination. Checking large areas and walkways by holding the detector close to the surface involves physical work. Also, areas which are unapproachable due to congestion of equipment, may go uncovered by contamination monitoring in order to eliminate the physical strain involved in such contamination monitoring and to cover unapproachable areas, a small size prototype device that can be operated remotely was fabricated. This device detects contamination instantaneously and accurately. This paper describes design and fabrication of the device used for floor contamination monitoring. (author)

  19. Measurement of gross alpha and gross beta activity concentrations in human tooth

    International Nuclear Information System (INIS)

    Soeguet, Omer; Aydin, Mehmet Fatih; Kuecuekoender, Erdal; Zorer, Ozlem Selcuk; Dogru, Mahmut

    2010-01-01

    The gross alpha and gross beta activity concentrations were measured in human tooth taken from 3 to 6 age-groups to 40 and over ones. Accumulated teeth samples are investigated in two groups as under and above 18 years. The gross alpha and beta radioactivity of human tooth samples was measured by using a gas-flow proportional counter (PIC-MPC 9604-α/β counter). In tooth samples, for female age-groups, the obtained results show that the mean gross alpha and gross beta activity concentrations varied between 0.534-0.203 and 0.010-0.453 Bq g -1 and the same concentrations for male age-groups varied between 0.009-1.168 and 0.071-0.204 Bq g -1 , respectively.

  20. Analysis of causes of combustible mixture explosions inside production floor areas

    Directory of Open Access Journals (Sweden)

    Lyapin Anton

    2016-01-01

    Full Text Available The work provides a cause analysis for major industrial explosions and a review of the causes of combustive air-gas mixture generation in a production environment. It has been established that during operation of explosive production facilities, it is process equipment that, as a rule, creates explosive environment inside the floor area. A qualitative method for determination of a potential accident has been reviewed. Analysis of the nature of explosion effect on building structures and equipment has shown that exposions characterised by absence of equipment and building structure disintegration normally have a localized character. It has been identified that during explosions inside process equipment, the largest structural damage occurs in spots hit by equipment debris. Complete destruction of building structures and equipment is caused by explosions inside equipment containing large quantities of combustible products. It has been identified that most explosions are accompanied by partial or total destruction of building structures and equipment. Therefore, measures taken to protect equipment and buildings from explosion effects lack efficiency.

  1. Pelvic floor muscle function in women with pelvic floor dysfunction

    DEFF Research Database (Denmark)

    Tibaek, Sigrid; Dehlendorff, Christian

    2014-01-01

    The objectives of this study were to investigate the level of pelvic floor muscle (PFM) function in women with pelvic floor dysfunction (PFD) referred by gynaecologists and urologists for in-hospital pelvic floor muscle training (PFMT), and to identity associated factors for a low level of PFM...

  2. Reaction of calves to two flooring materials offered simultaneously in one pen.

    NARCIS (Netherlands)

    Stefanowska, J.; Swierstra, D.; Smits, A.C.; Berg, van den J.V.; Metz, J.H.M.

    2002-01-01

    Now that group housing is replacing individual crates, so that calves can lie, stand and walk on the pen floor, the quality of the floor for group-housed calves has become the focus of attention. The reaction of two groups of four calves to a double area of floor made from two materials (wooden

  3. SUSTAINABLE TRAILER FLOORING

    OpenAIRE

    John Lu; Marc Chorney; Lowell Peterson

    2009-01-01

    Different trailer flooring materials, including wood-based, aluminum, steel, and synthetic plastic floors, were evaluated in accordance with their durability and sustainability to our natural environment. Wood-based trailer flooring is an eco-friendly product. It is the most sustainable trailer flooring material compared with fossil fuel-intensive steel, aluminum, and plastics. It is renewable and recyclable. Oak, hard maple, and apitong are strong and durable hardwood species that are curren...

  4. FLOOR IDENTIFICATION WITH COMMERCIAL SMARTPHONES IN WIFI-BASED INDOOR LOCALIZATION SYSTEM

    Directory of Open Access Journals (Sweden)

    H. J. Ai

    2016-06-01

    Full Text Available In this paper, we utilize novel sensors built-in commercial smart devices to propose a schema which can identify floors with high accuracy and efficiency. This schema can be divided into two modules: floor identifying and floor change detection. Floor identifying module starts at initial phase of positioning, and responsible for determining which floor the positioning start. We have estimated two methods to identify initial floor based on K-Nearest Neighbors (KNN and BP Neural Network, respectively. In order to improve performance of KNN algorithm, we proposed a novel method based on weighting signal strength, which can identify floors robust and quickly. Floor change detection module turns on after entering into continues positioning procedure. In this module, sensors (such as accelerometer and barometer of smart devices are used to determine whether the user is going up and down stairs or taking an elevator. This method has fused different kinds of sensor data and can adapt various motion pattern of users. We conduct our experiment with mobile client on Android Phone (Nexus 5 at a four-floors building with an open area between the second and third floor. The results demonstrate that our scheme can achieve an accuracy of 99% to identify floor and 97% to detecting floor changes as a whole.

  5. Modular Flooring System

    Science.gov (United States)

    Thate, Robert

    2012-01-01

    The modular flooring system (MFS) was developed to provide a portable, modular, durable carpeting solution for NASA fs Robotics Alliance Project fs (RAP) outreach efforts. It was also designed to improve and replace a modular flooring system that was too heavy for safe use and transportation. The MFS was developed for use as the flooring for various robotics competitions that RAP utilizes to meet its mission goals. One of these competitions, the FIRST Robotics Competition (FRC), currently uses two massive rolls of broadloom carpet for the foundation of the arena in which the robots are contained during the competition. The area of the arena is approximately 30 by 72 ft (approximately 9 by 22 m). This carpet is very cumbersome and requires large-capacity vehicles, and handling equipment and personnel to transport and deploy. The broadloom carpet sustains severe abuse from the robots during a regular three-day competition, and as a result, the carpet is not used again for competition. Similarly, broadloom carpets used for trade shows at convention centers around the world are typically discarded after only one use. This innovation provides a green solution to this wasteful practice. Each of the flooring modules in the previous system weighed 44 lb (.20 kg). The improvements in the overall design of the system reduce the weight of each module by approximately 22 lb (.10 kg) (50 %), and utilize an improved "module-to-module" connection method that is superior to the previous system. The MFS comprises 4-by-4-ft (.1.2-by- 1.2-m) carpet module assemblies that utilize commercially available carpet tiles that are bonded to a lightweight substrate. The substrate surface opposite from the carpeted surface has a module-to-module connecting interface that allows for the modules to be connected, one to the other, as the modules are constructed. This connection is hidden underneath the modules, creating a smooth, co-planar flooring surface. The modules are stacked and strapped

  6. A Floor-Map-Aided WiFi/Pseudo-Odometry Integration Algorithm for an Indoor Positioning System

    Science.gov (United States)

    Wang, Jian; Hu, Andong; Liu, Chunyan; Li, Xin

    2015-01-01

    This paper proposes a scheme for indoor positioning by fusing floor map, WiFi and smartphone sensor data to provide meter-level positioning without additional infrastructure. A topology-constrained K nearest neighbor (KNN) algorithm based on a floor map layout provides the coordinates required to integrate WiFi data with pseudo-odometry (P-O) measurements simulated using a pedestrian dead reckoning (PDR) approach. One method of further improving the positioning accuracy is to use a more effective multi-threshold step detection algorithm, as proposed by the authors. The “go and back” phenomenon caused by incorrect matching of the reference points (RPs) of a WiFi algorithm is eliminated using an adaptive fading-factor-based extended Kalman filter (EKF), taking WiFi positioning coordinates, P-O measurements and fused heading angles as observations. The “cross-wall” problem is solved based on the development of a floor-map-aided particle filter algorithm by weighting the particles, thereby also eliminating the gross-error effects originating from WiFi or P-O measurements. The performance observed in a field experiment performed on the fourth floor of the School of Environmental Science and Spatial Informatics (SESSI) building on the China University of Mining and Technology (CUMT) campus confirms that the proposed scheme can reliably achieve meter-level positioning. PMID:25811224

  7. A Summary--The Economics of Carpeting and Resilient Flooring. An Evaluation and Comparison.

    Science.gov (United States)

    Parks, George M.

    Of use to those concerned with the economics of flooring selection and maintenance, this comparison may prove useful as an estimating guide in the preparation of cost estimates for any flooring area where economics is a factor in the choice of materials. All costs attributed to carpet or resilient flooring have been obtained either by survey or…

  8. [Effect of prescribed burning on grassland nitrogen gross mineralization and nitrification].

    Science.gov (United States)

    Li, Yuzhong; Zhu, Tingcheng; Li, Jiandong; Zhou, Daowei

    2003-02-01

    The seasonal dynamics of nitrogen gross mineralization, nitrification, and mineral nitrogen consumption rates in burned and unburned Leymus chinensis grasslands were studied with 15N pool dilution technique. The results indicated that the gross mineralization and nitrification rates in burned area were higher than those in unburned area in April and May, and lower than those in unburned area in September. NH4(+)-N consumption rates were higher than unburned area in April and May, and lower in September. NO3(-)-N consumption rates were higher than control in April and May, and lower than control in July and September. The NH4(+)-N concentrations were higher in burned area in April, May and July, and no difference in September. NO3(-)-N concentrations were no difference between burned and unburned areas in April and May, and higher in burned areas in July and September.

  9. Analysis, design and interventions on valley floors at the city of Alfenas [MG

    Directory of Open Access Journals (Sweden)

    Francisco José Cardoso

    2009-04-01

    Full Text Available The floor of valleys are areas with important physical and environmental characteristics, interacting with diverse natural processes that occur in our planet. With the urbanization, degradation of such areas usually occurs, resulting in the physical, social and cultural withdrawing of the population from the urban river and stream lands. The purpose of this paper is to study the action of the public administration on valley floors and the management tools which may render feasable thee environmental preservation as well as environment and landscape renaturalization of such areas thus promoting echological and functional balance in the urban fluviatic lands. In order to prepare a proposal, several items were studied: the physical environmental characteristics of the valley floors, the transformations associated to urbanization. Based on this research, a plan was made for city of Alfenas [MG] as regards the management of the valley floor lands: a proposal of intervention in one of the hydrographic basins.

  10. Introductory guide to floors and flooring

    CSIR Research Space (South Africa)

    Billingham, PA

    1977-01-01

    Full Text Available not make use of the warming and cooling effects of direct contact with the ground. Indeed the precautions that are necessary to protect such floors against damp and decay may actually reduce the comfort levels within a house. This is because there is a... with resultant discomfort and extra heating costs. Today, in South Africa, most modern homesareof singlestorey con- struction with aconcrete floor slab in direct contact with theground which once again makes its full contribution to the comfort and structural...

  11. Physical and chemical test results of electrostatic safe flooring materials

    Science.gov (United States)

    Gompf, R. H.

    1988-01-01

    This test program was initiated because a need existed at the Kennedy Space Center (KSC) to have this information readily available to the engineer who must make the choice of which electrostatic safe floor to use in a specific application. The information, however, should be of value throughout both the government and private industry in the selection of a floor covering material. Included are the test results of 18 floor covering materials which by test evaluation at KSC are considered electrostatically safe. Tests were done and/or the data compiled in the following areas: electrostatics, flammability, hypergolic compatibility, outgassing, floor type, material thickness, and available colors. Each section contains the test method used to gather the data and the test results.

  12. Evaluation of gross radioactivity in foodstuffs

    International Nuclear Information System (INIS)

    Zorer, Oezlem Selcuk; Oeter, Cigdem

    2015-01-01

    The paper presents the results of radiological investigations of food products sampled in the summer and fall of 2011 and 2012 in different parts of Van, Turkey. Gross radioactivity measurements in food products were evaluated. Food items were divided into eight groups: (1) water, (2) fish, (3) cheese products, (4) fruits, (5) vegetables, (6) herbs, (7) walnut and (8) rock salt. The levels of the gross alpha and gross beta radioactivity in all food samples varied widely ranging from 0.070 to 10.885 Bq/g and from 0.132 to 48.285 Bq/g on dry mass basis, respectively. In one sample, gross alpha and gross beta activity concentrations were found to be relatively high according to the other samples and in all samples, the gross alpha radioactivity was measured lower than the gross beta radioactivity. The gross α and gross β activities were measured by using α/β counter of the multi-detector low background system (PIC MPC-9604).

  13. Evaluation of gross radioactivity in foodstuffs

    Energy Technology Data Exchange (ETDEWEB)

    Zorer, Oezlem Selcuk; Oeter, Cigdem [Yuzuncu Yil Univ., Van (Turkey). Dept. of Chemistry

    2015-05-15

    The paper presents the results of radiological investigations of food products sampled in the summer and fall of 2011 and 2012 in different parts of Van, Turkey. Gross radioactivity measurements in food products were evaluated. Food items were divided into eight groups: (1) water, (2) fish, (3) cheese products, (4) fruits, (5) vegetables, (6) herbs, (7) walnut and (8) rock salt. The levels of the gross alpha and gross beta radioactivity in all food samples varied widely ranging from 0.070 to 10.885 Bq/g and from 0.132 to 48.285 Bq/g on dry mass basis, respectively. In one sample, gross alpha and gross beta activity concentrations were found to be relatively high according to the other samples and in all samples, the gross alpha radioactivity was measured lower than the gross beta radioactivity. The gross α and gross β activities were measured by using α/β counter of the multi-detector low background system (PIC MPC-9604).

  14. Investigation of floor Nusselt number in floor heating system for insulated ceiling conditions

    International Nuclear Information System (INIS)

    Karadag, Refet; Teke, Ismail

    2007-01-01

    In this study, in a floor heated room, natural convection heat transfer over the floor is analysed numerically for different thermal conditions. An equation relevant to Nusselt number over the floor has been obtained by using the numerical data. Different equations are given in the literature. They consider the effect of floor Rayleigh number while neglecting the effect of wall and ceiling thermal conditions. Numerical data obtained in this study show that the Nusselt number over the floor depends on not only the floor Rayleigh number but also the wall Rayleigh number (for insulated ceiling conditions). The equations given in the literature are different from each other due to their not considering the effect of wall and ceiling Rayleigh numbers. This difference between the equations may be eliminated by obtaining an equation containing the effect of floor, wall and ceiling Rayleigh numbers. In this new approach, an equation relevant to the floor Nusselt number that depends on the floor and wall Rayleigh numbers has been obtained in the floor heating system for insulated ceiling conditions. The equation obtained in this study has been compared with the equations given in the literature. It has been seen that the equation obtained in this study matches the numerical values under more extensive thermal conditions than the equations given in the literature. The maximum deviation for the equations given in the literature is 35%, but in the current study, the maximum deviation has been found to be 10%. As a result, it is more convenient to use the equation found in the new approach as a function of Rayleigh number over the floor and wall for insulated ceiling conditions

  15. User Identification Using Gait Patterns on UbiFloorII

    Science.gov (United States)

    Yun, Jaeseok

    2011-01-01

    This paper presents a system of identifying individuals by their gait patterns. We take into account various distinguishable features that can be extracted from a user’s gait and then divide them into two classes: walking pattern and stepping pattern. The conditions we assume are that our target environments are domestic areas, the number of users is smaller than 10, and all users ambulate with bare feet considering the everyday lifestyle of the Korean home. Under these conditions, we have developed a system that identifies individuals’ gait patterns using our biometric sensor, UbiFloorII. We have created UbiFloorII to collect walking samples and created software modules to extract the user’s gait pattern. To identify the users based on the gait patterns extracted from walking samples over UbiFloorII, we have deployed multilayer perceptron network, a feedforward artificial neural network model. The results show that both walking pattern and stepping pattern extracted from users’ gait over the UbiFloorII are distinguishable enough to identify the users and that fusing two classifiers at the matching score level improves the recognition accuracy. Therefore, our proposed system may provide unobtrusive and automatic user identification methods in ubiquitous computing environments, particularly in domestic areas. PMID:22163758

  16. Requirement of radiochemical recovery determination for gross alpha and gross beta estimation in drinking water

    International Nuclear Information System (INIS)

    Raveendran, Nanda; Rao, D.D.; Hegde, A.G.

    2010-01-01

    Presence of radionuclides in drinking water which emits Alpha and Beta particles are the potential sources of internal exposure in drinking water. Gross alpha and gross beta determination in drinking water and packaged drinking water (PDW) as per BIS (Bureau of Indian standards) standards is discussed here. The methods have been tested to account for losses in the radiochemical procedures using radionuclides such as 137 Cs, 90 Sr, 226 Ra, 239 Pu, 243 Am, 232 U. The methods have also been validated in an IAEA proficiency test conducted during 2009. Monitoring of gross alpha and gross beta activity observed in drinking water/packaged drinking water from various states of India were within the limits set by BIS. Average radiochemical recoveries of 84% and 63% were obtained for gross α and gross β respectively. (author)

  17. Assessing the effects of land-use changes on annual average gross erosion

    Directory of Open Access Journals (Sweden)

    Armando Brath

    2002-01-01

    Full Text Available The effects of land-use changes on potential annual gross erosion in the uplands of the Emilia-Romagna administrative region, a broad geographical area of some 22 000 km2 in northern-central Italy, have been analysed by application of the Universal Soil Loss Equation (USLE. The presence of an extended mountain chain, particularly subject to soil erosion, makes the estimation of annual gross erosion relevant in defining regional soil-conservation strategies. The USLE, derived empirically for plots, is usually applied at the basin scale. In the present study, the method is implemented in a distributed framework for the hilly and mountainous portion of Emilia-Romagna through a discretisation of the region into elementary square cells. The annual gross erosion is evaluated by combining morphological, pedological and climatic information. The stream network and the tributary area drained by each elementary cell, which are needed for the local application of the USLE, are derived automatically from a Digital Elevation Model (DEM of grid size 250 x 250 m. The rainfall erosivity factor is evaluated from local estimates of rainfall of six-hour storm duration and two-year return period. The soil erodibility and slope length-steepness factors are derived from digital maps of land use, pedology and geomorphology. Furthermore, historical land-use maps of the district of Bologna (a large portion — 3720 km2 — of the area under study, allow the effect of actual land use changes on the soil erosion process to be assessed. The analysis shows the influence of land-use changes on annual gross erosion as well as the increasing vulnerability of upland areas to soil erosion processes during recent decades. Keywords: USLE, gross erosion, distributed modelling, land use changes, northern-central Italy

  18. Effect of pelvic floor rehabilitation technique in preventing the postpartum pelvic floor dysfunction

    Directory of Open Access Journals (Sweden)

    Shi-Qiong Li

    2017-04-01

    Full Text Available Objective: To explore the effect of pelvic floor rehabilitation technique in preventing the postpartum pelvic floor dysfunction and on the sexual life quality. Methods: A total of 286 puerpera with pelvic floor dysfunction who were admitted in our hospital from May, 2014 to May, 2015 42 d after delivery were included in the study, and randomized into the treatment group and the control group with 143 cases in each group. After guidance, the puerpera in the control group were given pelvic floor muscle training by themselves at home. On this basis, the puerpera in the treatment group were treated by the pelvic floor rehabilitation apparatus. The puerpera in the two groups were treated for 4 weeks. The pelvic floor function before treatment, 6 months and 1 year after delivery was detected. The color Doppler ultrasound apparatus was used to detect BSD, PUVA, UVJ-M, and BND 3 months after delivery. Results: BND, PUVA-R, PUVA-S, and UVJ-M 3 months after delivery in the treatment groups were significantly lower than those in the control group, while BSD-S was significantly higher than that in the control group. The improvement of type I and II muscle fiber fatigue (%, POP-Q degree, AP indication point (cm, and vaginal dynamic pressure (cmH2O was significantly superior to that in the control group. The comparison of pelvic floor muscle strength classification before treatment between the two groups was not statistically significant. After treatment, the pelvic floor muscle in the two groups was significantly strengthened, and the proportion of V grade patients was significantly increased when compared with before treatment. Conclusions: The postpartum early pelvic floor rehabilitation technique can effectively enhance the pelvic floor function, and prevent the postpartum pelvic floor dysfunction, with an accurate efficacy; therefore, it deserves to be widely recommended in the clinic.

  19. Effect of different flooring systems on claw conformation of dairy cows.

    Science.gov (United States)

    Telezhenko, E; Bergsten, C; Magnusson, M; Nilsson, C

    2009-06-01

    The effect of different flooring surfaces in walking and standing areas on claw conformation, claw horn growth, and wear was studied in 2 experiments during 2 consecutive housing seasons in a research dairy herd of 170 cows. In experiment 1, the flooring systems tested were solid rubber mats, mastic asphalt with and without rubber-matted feed-stalls, and aged concrete slats. In experiment 2, slatted concrete flooring was compared with slatted rubber flooring. The cows were introduced to the respective flooring systems in early lactation and their claws were trimmed before the exposure period. Toe length, toe angle, sole concavity, and claw width, as well as claw growth and wear rates were recorded for lateral and medial claws of the left hind limb. Claw asymmetry calculations were based on these claw measurements and on differences in sole protrusion between lateral and medial soles. Asphalt floors caused shorter toe length and steeper toe angle. They also increased wear on rear claws (5.30 +/- 0.31 and 5.95 +/- 0.33 mm/mo for lateral and medial claw, respectively; LSM +/- SE) and horn growth rate (5.12 +/- 0.36 and 5.83 +/- 0.31 mm/mo of lateral and medial claws, respectively). Rubber mats instead of asphalt in walking areas reduced wear (1.36 +/- 0.19 and 2.02 +/- 0.20 mm/mo for lateral and medial claw, respectively) and claw growth (3.83 +/- 0.23 and 3.94 +/- 0.17 mm/mo for lateral and medial claw, respectively). Rubber-matted feed-stalls together with asphalt walkways decreased claw wear (3.29 +/- 0.31 and 4.10 +/- 0.32 mm/mo for lateral and medial claw, respectively). The concavity of claw soles was reduced on asphalt, especially in the lateral rear claws. Rubber matting in feed-stalls prevented loss of sole concavity compared with asphalt. Claw asymmetry did not differ between flooring systems. While different access to abrasive flooring affected claw conformation, there was no evidence that flooring system influenced the disproportion between lateral and

  20. Decontamination of floor surfaces

    International Nuclear Information System (INIS)

    Smirous, F.

    1983-01-01

    Requirements are presented put on the surfaces of floors of radiochemical workplaces. The mechanism is described of retaining the contaminant in the surface of the flooring, ways of reducing the hazards of floor surface contamination, decontamination techniques and used decontamination agents. (J.P.)

  1. Monitoring of gross alpha, gross beta and tritium activities in portuguese drinking waters

    International Nuclear Information System (INIS)

    Lopes, I.; Madruga, M.J.; Ferrador, G.O.; Sequeira, M.M.; Oliveira, E.J.; Gomes, A.R.; Rodrigues, F.D.; Carvalho, F.P.

    2006-01-01

    The gross beta and tritium activities in the forty Portuguese drinking waters analyzed using the ISO standard methods (Portuguese Guidelines) are below the guidance levels proposed in the Portuguese Drinking Water Quality Guidelines. In what concerns the gross alpha activity only 18% exceeded the recommended level. In general, it can be concluded that the ingestion of these drinking waters does not create a radiological hazard to the human consumption, however, more detailed analyses will be necessary mainly the determinations of the individual alpha emitters radionuclide concentrations. The minimum gross alpha and gross beta detectable activities by L.S.C. methodology are higher than for the proportional counting technique (ISO method). Higher concentration factors will be needed to reach lower required detection limits. (authors)

  2. NM Gross Receipts Baseline

    Data.gov (United States)

    Earth Data Analysis Center, University of New Mexico — This layer represents boundaries for New Mexico's gross receipts tax districts as identified on the "Gross Receipts Tax Rate Schedule" published by the Taxation and...

  3. A global assessment of gross and net land change dynamics for current conditions and future scenarios

    Science.gov (United States)

    Fuchs, Richard; Prestele, Reinhard; Verburg, Peter H.

    2018-05-01

    The consideration of gross land changes, meaning all area gains and losses within a pixel or administrative unit (e.g. country), plays an essential role in the estimation of total land changes. Gross land changes affect the magnitude of total land changes, which feeds back to the attribution of biogeochemical and biophysical processes related to climate change in Earth system models. Global empirical studies on gross land changes are currently lacking. Whilst the relevance of gross changes for global change has been indicated in the literature, it is not accounted for in future land change scenarios. In this study, we extract gross and net land change dynamics from large-scale and high-resolution (30-100 m) remote sensing products to create a new global gross and net change dataset. Subsequently, we developed an approach to integrate our empirically derived gross and net changes with the results of future simulation models by accounting for the gross and net change addressed by the land use model and the gross and net change that is below the resolution of modelling. Based on our empirical data, we found that gross land change within 0.5° grid cells was substantially larger than net changes in all parts of the world. As 0.5° grid cells are a standard resolution of Earth system models, this leads to an underestimation of the amount of change. This finding contradicts earlier studies, which assumed gross land changes to appear in shifting cultivation areas only. Applied in a future scenario, the consideration of gross land changes led to approximately 50 % more land changes globally compared to a net land change representation. Gross land changes were most important in heterogeneous land systems with multiple land uses (e.g. shifting cultivation, smallholder farming, and agro-forestry systems). Moreover, the importance of gross changes decreased over time due to further polarization and intensification of land use. Our results serve as an empirical database for

  4. Determination of gross gamma and gross beta activities in liquid effluent samples. Phase I

    International Nuclear Information System (INIS)

    Curtis, K.E.; Sood, S.P.

    1985-08-01

    Several inadequacies in the presently used procedures for gross gamma and gross beta measurements in aqueous wastes have been identified. Both the presence of suspended particulate activity and the use of cesium-137 as a calibration standard can cause gross gamma measurements to overestimate the actual activity in the sample. At the same time, sample preparation for the determination of gross beta activities causes large losses of radioiodine before the measurement step and the presence of solid material can cause a serious decrease in the beta counting efficiency. A combination of these errors could result in large discrepancies between the results obtained by the two measurement methods. Improved procedures are required to overcome these problems

  5. Flooring-systems and their interaction with usage of the floor

    DEFF Research Database (Denmark)

    Pedersen, Lars; Frier, Christian; Andersen, Lars Vabbersgaard

    2017-01-01

    Some flooring-system designs might be sensitive to their vibrational performance, as there might be the risk that serviceability-limit-state problems may be encountered. For evaluating the vibrational performance of the flooring-system at the design stage, decisions need to be made by the enginee...

  6. Inter- and intrapatient variability of facial nerve response areas in the floor of the fourth ventricle.

    Science.gov (United States)

    Bertalanffy, Helmut; Tissira, Nadir; Krayenbühl, Niklaus; Bozinov, Oliver; Sarnthein, Johannes

    2011-03-01

    Surgical exposure of intrinsic brainstem lesions through the floor of the 4th ventricle requires precise identification of facial nerve (CN VII) fibers to avoid damage. To assess the shape, size, and variability of the area where the facial nerve can be stimulated electrophysiologically on the surface of the rhomboid fossa. Over a period of 18 months, 20 patients were operated on for various brainstem and/or cerebellar lesions. Facial nerve fibers were stimulated to yield compound muscle action potentials (CMAP) in the target muscles. Using the sites of CMAP yield, a detailed functional map of the rhomboid fossa was constructed for each patient. Lesions resected included 14 gliomas, 5 cavernomas, and 1 epidermoid cyst. Of 40 response areas mapped, 19 reached the median sulcus. The distance from the obex to the caudal border of the response area ranged from 8 to 27 mm (median, 17 mm). The rostrocaudal length of the response area ranged from 2 to 15 mm (median, 5 mm). Facial nerve response areas showed large variability in size and position, even in patients with significant distance between the facial colliculus and underlying pathological lesion. Lesions located close to the facial colliculus markedly distorted the response area. This is the first documentation of variability in the CN VII response area in the rhomboid fossa. Knowledge of this remarkable variability may facilitate the assessment of safe entry zones to the brainstem and may contribute to improved outcome following neurosurgical interventions within this sensitive area of the brain.

  7. Evaluation of flooring produced from small diameters logs of Eucalyptus sp. clones

    Directory of Open Access Journals (Sweden)

    José Reinaldo Moreira da Silva

    2010-12-01

    Full Text Available This study evaluated two Eucalyptus clones, MN 249 and MN 89, for the flooring production using small diameters logs. It was considered the wood physical properties - NBR 7190/97 (ABNT, 1997 and simulation of the product in service (ASTM D 2394/83 with two thicknesses, 8 and 14 mm. The basic density of the clone 89 NM was the highest one (0,615 g/cm3. The contractions were more pronounced in clone NM 249, however, the anisotropy coefficient of this clone was small. In the simulation tests, the floor produced by clone MN 249 presented the lowest deformation rate. The floor of 8 mm, in addition to the differences between clones, there was significant interaction between the positions for the indentation test caused by loads applied in small areas. The deformations obtained for the floor with 14 mm thickness, produced with the MN clone 89, were higher than those found in the literature for the indentation load applied on a small area test. The clone MN 249 presented the best results in both thicknesses.

  8. Activity level of gross α and gross β in airborne aerosol samples around the Qinshan NPP

    International Nuclear Information System (INIS)

    Chen Bin; Ye Jida; Chen Qianyuan; Wu Xiaofei; Song Weili; Wang Hongfeng

    2007-01-01

    The monitoring results of gross α and gross 13 activity from 2001 to 2005 for environmental airborne aerosol samples around the Qinshan NPP base are presented in this paper. A total of 170 aerosol samples were collected from monitoring sites of Caichenmen village, Qinlian village, Xiajiawan village and Yangliucun village around the Qinshan NPP base. The measured specific activity of gross α and gross β are in the range of 0.02-0.38 mBq/m 3 and 0.10-1.81 mBq/m 3 , respectively, with an average of 0.11 mBq/m 3 and 0.45mBq/m 3 , respectively. They are lower than the average of 0.15 mBq/m 3 and 0.52 mBq/m 3 , of reference site at Hangzhou City. It is indicated that the specific activity of gross α and gross β for environmental aerosol samples around the Qinshan NPP base had not been increased in normal operating conditions of the NPP. (authors)

  9. Supporting shop floor intelligence

    DEFF Research Database (Denmark)

    Carstensen, Peter; Schmidt, Kjeld; Wiil, Uffe Kock

    1999-01-01

    Many manufacturing enterprises are now trying to introduce various forms of flexible work organizations on the shop floor. However, existing computer-based production planning and control systems pose severe obstacles for autonomous working groups and other kinds of shop floor control to become r......-to-day production planning by supporting intelligent and responsible workers in their situated coordination activities on the shop floor....

  10. Landscape History of Grosses Moos, NW Swiss Alpine Foreland.

    Science.gov (United States)

    Joanna Heer, Aleksandra; Adamiec, Grzegorz; Veit, Heinz; May, Jan-Hendrik; Novenko, Elena; Hajdas, Irka

    2017-04-01

    The western Swiss Plateau with Lake Neuchâtel is part of the alpine foreland and among the key areas for the reconstruction of environmental changes since the last postglacial. This study was carried out in a landscape located NE of the lake and called Grosses Moos (The Large Fen) - currently designated the Swiss largest, continuous farming area, after the fen was drained in course of landscape engineering projects performed in Switzerland at the end of the 19th century. The study contributes new results from nine excavations of littoral ridges identified in Grosses Moos, and integrates sedimentology, paleo-environmental analysis and three independent chronological methods. Radiocarbon dating, pollen analysis and optically stimulated luminescence (OSL) were applied to the sediments. While pollen and radiocarbon follow the standard procedures, the evaluation of the luminescence age estimates demanded adjustment according to the physical and microdosimetric properties of the alpine quartz, and consideration of the peculiarities of the changing littoral environments of Grosses Moos. The Grosses Moos landscape developed on the temporary surface of the post-Last Glacial sedimentary infill of the over-deepened glacial Aare valley. In this study the landscape history has been fitted into the existing supraregional time scales of NGRIP, the Swiss bio-zones system and the human history based on archaeological and historic records and covers a time span of up to 15'000 yr b2k. The wide-ranging suite of geomorphic features and sedimentary sequences, including littoral lake sediments, beach ridges, dunes, palaeo-channels, peat and colluvial deposits, enable the extensive reconstruction of spatially and temporally variable natural shaping processes. In addition, our results indicate remobilization of soil, colluvium, and sediment due to human settlement activities since the Neolithic - with an important increase in sediment load and spatial variability since the Bronze Age

  11. A global assessment of gross and net land change dynamics for current conditions and future scenarios

    Directory of Open Access Journals (Sweden)

    R. Fuchs

    2018-05-01

    Full Text Available The consideration of gross land changes, meaning all area gains and losses within a pixel or administrative unit (e.g. country, plays an essential role in the estimation of total land changes. Gross land changes affect the magnitude of total land changes, which feeds back to the attribution of biogeochemical and biophysical processes related to climate change in Earth system models. Global empirical studies on gross land changes are currently lacking. Whilst the relevance of gross changes for global change has been indicated in the literature, it is not accounted for in future land change scenarios. In this study, we extract gross and net land change dynamics from large-scale and high-resolution (30–100 m remote sensing products to create a new global gross and net change dataset. Subsequently, we developed an approach to integrate our empirically derived gross and net changes with the results of future simulation models by accounting for the gross and net change addressed by the land use model and the gross and net change that is below the resolution of modelling. Based on our empirical data, we found that gross land change within 0.5° grid cells was substantially larger than net changes in all parts of the world. As 0.5° grid cells are a standard resolution of Earth system models, this leads to an underestimation of the amount of change. This finding contradicts earlier studies, which assumed gross land changes to appear in shifting cultivation areas only. Applied in a future scenario, the consideration of gross land changes led to approximately 50 % more land changes globally compared to a net land change representation. Gross land changes were most important in heterogeneous land systems with multiple land uses (e.g. shifting cultivation, smallholder farming, and agro-forestry systems. Moreover, the importance of gross changes decreased over time due to further polarization and intensification of land use. Our results serve as

  12. A Fuzzy Logic Model to Classify Design Efficiency of Nursing Unit Floors

    Directory of Open Access Journals (Sweden)

    Tuğçe KAZANASMAZ

    2010-01-01

    Full Text Available This study was conducted to determine classifications for the planimetric design efficiency of certain public hospitals by developing a fuzzy logic algorithm. Utilizing primary areas and circulation areas from nursing unit floor plans, the study employed triangular membership functions for the fuzzy subsets. The input variables of primary areas per bed and circulation areas per bed were fuzzified in this model. The relationship between input variables and output variable of design efficiency were displayed as a result of fuzzy rules. To test existing nursing unit floors, efficiency output values were obtained and efficiency classes were constructed by this model in accordance with general norms, guidelines and previous studies. The classification of efficiency resulted from the comparison of hospitals.

  13. SIMON: A mobile robot for floor contamination surveys

    International Nuclear Information System (INIS)

    Dudar, E.; Teese, G.; Wagner, D.

    1991-01-01

    The Robotics Development group at the Savannah River Site is developing an autonomous robot to perform radiological surveys of potentially contaminated floors. The robot scans floors at a speed of one-inch/second and stops, sounds an alarm, and flashes lights when contamination in a certain area is detected. The contamination of interest here is primarily alpha and beta-gamma. The contamination levels are low to moderate. The robot, a Cybermotion K2A, is radio controlled, uses dead reckoning to determine vehicle position, and docks with a charging station to replenish its batteries and calibrate its position. It has an ultrasonic collision avoidance system as well as two safety bumpers that will stop the robot's motion when they are depressed. Paths for the robot are preprogrammed and the robot's motion can be monitored on a remote screen which shows a graphical map of the environment. The radiation instrument being used is an Eberline RM22A monitor. This monitor is microcomputer based with a serial I/O interface for remote operation. Up to 30 detectors may be configured with the RM22A. For our purposes, two downward-facing gas proportional detectors are used to scan floors, and one upward-facing detector is used for radiation background compensation. SIMON is interfaced with the RM22A in such a way that it scans the floor surface at one-inch/second, and if contamination is detected, the vehicle stops, alarms, and activates a voice synthesizer. Future development includes using the contamination data collected to provide a graphical contour map of a contaminated area. 3 refs

  14. Levels of radioactivity in fish from streams near F-Area and H-Area seepage basins

    International Nuclear Information System (INIS)

    Murphy, C.E. Jr.; Loehle, C.

    1991-05-01

    This report summarizes results of recent analyses of radioactivity in fish from SRS streams near the F-Area and H-Area seepage basins. Fish were collected from headwater areas of Four Mile Creek and Pen Branch, from just below the H-Area seepage basin, and from three sites downstream in Four Mile Creek. These fish were analyzed for gross alpha and gross beta radioactivity using standard EPA methods. Levels of gross alpha and nonvolatile beta radioactivity in fish were found to be comparable to levels previously reported for these sites. Gross alpha activity was not found to be influenced by Separations Area discharges. Nonvolatile beta activity was higher in the nonvolatile beta activity was attributable to Cs-137 and K-40. The dosimetric consequences of consuming fish from this area were found to be well below DOE guidelines

  15. 17 CFR 3.11 - Registration of floor brokers and floor traders.

    Science.gov (United States)

    2010-04-01

    ... 17 Commodity and Securities Exchanges 1 2010-04-01 2010-04-01 false Registration of floor brokers and floor traders. 3.11 Section 3.11 Commodity and Securities Exchanges COMMODITY FUTURES TRADING... a contract market or registered as a derivatives transaction execution facility by the Commission...

  16. Methods and Principles of Determining the Footwear and Floor Tribological Characteristics

    Directory of Open Access Journals (Sweden)

    D. Stamenković

    2017-09-01

    Full Text Available There are many standards relating to the anti-slip properties of footwear and flooring. These standards describe the different test methods and procedures for determining the footwear and floor slip resistance in different conditions. In this paper authors systematize the standards in this field applied in the EU and in Serbia and cite the Serbian institutes which are certified for this type of testing. In addition, the authors have carried out an analysis and comparison of the tests that are defined in these standards, indicating their advantages and disadvantages. Importance of the static and kinetic friction testing in determining the anti-slip properties of footwear and flooring is specifically indicated. Considering the current standards in area of slip resistance of the footwear and floor covering authors have determined the testing conditions for laboratory measuring the friction forces of different floor and footwear materials. The laboratory measurement has carried out at Faculty of Mechanical Engineering in Niš. The measuring results and their analysis are presented in the paper, as well.

  17. 26 CFR 1.61-1 - Gross income.

    Science.gov (United States)

    2010-04-01

    ... 26 Internal Revenue 2 2010-04-01 2010-04-01 false Gross income. 1.61-1 Section 1.61-1 Internal Revenue INTERNAL REVENUE SERVICE, DEPARTMENT OF THE TREASURY (CONTINUED) INCOME TAX (CONTINUED) INCOME TAXES (CONTINUED) Definition of Gross Income, Adjusted Gross Income, and Taxable Income § 1.61-1 Gross...

  18. Defect characterization, diagnosis and repair of wood flooring based on a field survey

    International Nuclear Information System (INIS)

    Delgado, A.; Pereira, C.; Brito, J. de; Silvestre, J.D.

    2018-01-01

    A statistical characterization of defects in 35 buildings and 98 wood floorings (softwood and hardwood floors, and laminated and engineered wood floors), their diagnostic methods and repair solutions is presented. An expert system for inspecting wood flooring, comprising the classification of defects, their most probable causes, diagnostic methods and repair techniques, was used. Results include age, affected area, severity and frequency of defects and their main causes, as well as appropriate diagnostic methods, preventive and curative repair solutions most prescribed and the most significant correlations. Scratches were detected in more than five sixths of the sample, highly associated with exterior mechanical actions, and with an inadequate finishing layer. Wearing of the finishing layer was detected in a quarter of the inspected floorings. Accordingly, the application of a suitable finishing layer and, alternatively, its replacement are the most prescribed repair techniques. [es

  19. Changes in conifer and deciduous forest foliar and forest floor chemistry and basal area tree growth across a nitrogen (N) deposition gradient in the northeastern US

    International Nuclear Information System (INIS)

    Boggs, Johnny L.; McNulty, Steven G.; Pardo, Linda H.

    2007-01-01

    We evaluated foliar and forest floor chemistry across a gradient of N deposition in the Northeast at 11 red spruce (Picea rubens Sarg.) sites in 1987/1988 and foliar and forest floor chemistry and basal area growth at six paired spruce and deciduous sites in 1999. The six red spruce plots were a subset of the original 1987/1988 spruce sites. In 1999, we observed a significant correlation between mean growing season temperature and red spruce basal area growth. Red spruce and deciduous foliar %N correlated significantly with N deposition. Although N deposition has not changed significantly from 1987/1988 to 1999, net nitrification potential decreased significantly at Whiteface. This decrease in net potential nitrification is not consistent with the N saturation hypothesis and suggests that non-N deposition controls, such as climatic factors and immobilization of down dead wood, might have limited N cycling. - Data from the 1999 remeasurement of the red spruce forests suggest that N deposition, to some extent, is continuing to influence red spruce across the northeastern US as illustrated by a significant correlation between N deposition and red spruce foliar %N. Our data also suggest that the decrease in forest floor %N and net nitrification potential across sites from 1987 to 1999 may be due to factors other than N deposition, such as climatic factors and N immobilization in fine woody material (<5 cm diameter)

  20. Effect of rubber flooring on group-housed sows' gait and claw and skin lesions.

    Science.gov (United States)

    Bos, E-J; van Riet, M M J; Maes, D; Millet, S; Ampe, B; Janssens, G P J; Tuyttens, F A M

    2016-05-01

    This study evaluated the influence of floor type on sow welfare in terms of lameness, claw lesions, and skin lesions. In a 2 × 3 factorial design, we have investigated the effect of rubber coverings on concrete floors and the effect of 3 levels of dietary zinc supplementation on locomotion and claw and skin lesions in group-housed sows. Six groups of 21 ± 4 hybrid sows were monitored during 3 successive reproductive cycles. The sows were group housed from d 28 after insemination (d 0) until 1 wk before expected farrowing date (d 108) in pens with either exposed concrete floors or concrete floors covered with rubber in part of the lying area and the fully slatted area. During each reproductive cycle, locomotion and skin lesions were assessed 4 times (d 28, 50, 108, and 140) and claw lesions were assessed twice (d 50 and 140). Results are given as least squares means ± SE. Locomotion and claw scores were given in millimeters, on analog scales of 150 and 160 mm, respectively. Here, we report on the effect of floor type, which did not interact with dietary zinc concentration ( > 0.10 for all variables). At move to group (d 28) and mid gestation (d 50), no differences between floor treatments were seen in locomotion ( > 0.10). At the end of gestation (d 108), sows housed on rubber flooring scored 9.9 ± 4.1 mm better on gait ( flooring at mid gestation (d 50). However, sows on rubber flooring scored worse for "vertical cracks in the wall horn" (difference of 3.4 ± 1.7 mm; = 0.04). At the end of lactation (d 140), both "white line" (difference of 2.9 ± 1 mm; = 0.02) and "claw length" (difference of 4.7 ± 1.4 mm; flooring. No differences for skin lesions were observed between floor treatments. The improved scores for gait toward the end of gestation and some types of claw disorders at mid gestation suggest that rubber flooring in group housing has a beneficial effect on the overall leg health of sows. The documented increase in vertical cracks in the wall horn at d

  1. Floor cooler for floor trough of a nuclear reactor

    International Nuclear Information System (INIS)

    Friedrich, H.J.

    1985-01-01

    Cooling pipes are situated below the floor trough of a BWR, which are connected to the annular distribution or collection pipes. The distribution and collection pipes are connected by parallel hairpin pipes with involute shape to the centre of the floor trough. These hairpin pipes are situated in a lower plane than the annular distribution pipe to the centre and in a higher plane from the centre to the outer annular collector pipe. (orig./HP) [de

  2. Transvaginal Pelvic Floor Muscle Injection Technique: A Cadaver Study.

    Science.gov (United States)

    Gupta, Priyanka; Ehlert, Michael; Sirls, Larry T; Peters, Kenneth

    Women with pelvic floor dysfunction can have tender areas on vaginal examination, which can be treated with trigger-point injections. There are no publications to evaluate the accuracy of pelvic floor muscle injections. Trigger-point injections were performed on 2 fresh cadaveric pelvises using a curved nasal cannula guide and 7-in spinal needle. This was performed using our standard template of 2 sets of injections at the 1-, 3-, and 5-o'clock positions distally and proximally. The first pelvis was dissected to examine dye penetration. Based on these results, we modified our technique and repeated the injections on the second cadaver. We dissected the second pelvis and compared our findings. The 1-o'clock proximal and distal injections stained the obturator internus and externus near the insertion at the ischiopubic ramus. The 3-o'clock injections stained the midbody of the pubococcygeus and puborectalis. The distal 5-o'clock position was too deep and stained the fat of the ischiorectal space. The proximal 5-o'clock injection stained the area of the pudendal nerve. Our goal at the distal 5-o'clock position was to infuse the iliococcygeus muscle, so we shortened the needle depth from 2 to 1 cm beyond the cannula tip. In our second dissection, the distal 5-o'clock injection again stained only the fat of the ischiorectal space. This is the first study to characterize the distribution of pelvic floor muscle injections in a cadaver model and confirms the ability to deliver medications effectively to the pelvic floor muscles.

  3. [Functional aspects of pelvic floor surgery].

    Science.gov (United States)

    Wagenlehner, F M E; Gunnemann, A; Liedl, B; Weidner, W

    2009-11-01

    Pelvic floor dysfunctions are frequently seen in females. The human pelvic floor is a complex structure and heavily stressed throughout female life. Recent findings in the functional anatomy of the pelvic floor have led to a much better understand-ing, on the basis of which enormous improvements in the therapeutic options have arisen. The pelvic floor activity is regulated by three main muscular forces that are responsible for vaginal tension and suspension of the pelvic floor -organs, bladder and rectum. For different reasons laxity in the vagina or its supporting ligaments as a result of altered connective tissue can distort this functional anatomy. A variety of symptoms can derive from these pelvic floor dysfunctions, such as urinary urge and stress incontinence, abnormal bladder emptying, faecal incontinence, obstructive bowel disease syndrome and pelvic pain. Pelvic floor reconstruction is nowadays driven by the concept that in the case of pelvic floor symptoms restoration of the anatomy will translate into restoration of the physiology and ultimately improve the patients' symptoms. The exact surgical reconstruction of the anatomy is there-fore almost exclusively focused on the restoration of the lax pelvic floor ligaments. An exact identification of the anatomic lesions preoperatively is eminently necessary, to allow for an exact anatomic reconstruction with respect to the muscular forces of the pelvic floor. Georg Thieme Verlag Stuttgart * New York.

  4. Pelvic floor physical therapy in urogynecologic disorders.

    Science.gov (United States)

    Kotarinos, Rhonda K

    2003-08-01

    Physical therapists are uniquely qualified to treat pelvic floor dysfunction with conservative management techniques. Techniques associated with incontinence and support functions of the pelvic floor include bladder training and pelvic floor rehabilitation: pelvic floor exercises, biofeedback therapy, and pelvic floor electrical stimulation. Pain associated with mechanical pelvic floor dysfunction can be treated by physical therapists utilizing various manual techniques and modalities. Research documents that conservative management is effective in treating many conditions associated with pelvic floor dysfunction. Research should be conducted to determine if addressing diastasis recti and contracture of the pelvic floor musculature should be a component of the standard physical therapy protocol.

  5. School Flooring Factors

    Science.gov (United States)

    McGrath, John

    2012-01-01

    With all of the hype that green building is receiving throughout the school facility-management industry, it's easy to overlook some elements that may not be right in front of a building manager's nose. It is helpful to examine the role floor covering plays in a green building project. Flooring is one of the most significant and important systems…

  6. Effect of Different Flooring Designs on the Performance and Foot Pad Health in Broilers and Turkeys.

    Science.gov (United States)

    Chuppava, Bussarakam; Visscher, Christian; Kamphues, Josef

    2018-05-03

    Litter quality has a significant influence on the performance and foot pad health in poultry. The objective of this study was to evaluate the effects of different types of flooring designs on the performance and foot pad health in fattening broilers and turkeys. Three trials were conducted for each species using a total of 720 Ross 308 broilers and 720 Big 6 turkeys. After day seven, animals were randomly assigned to four groups with three subgroups each: G1—floor pens with litter, G2—floor pens with litter and floor heating, G3—partially-slatted flooring, including a littered area, and G4—fully-slatted flooring with a sand bath (900 cm²). Animals of both species had a significantly higher final body weight at dissection (day 36) after being reared on fully-slatted floors compared to common littered floors. In turkeys, the feed conversion ratio was worse in G4 (1.53 ± 0.04) than in G1 (1.47 ± 0.02) and G2 (1.48 ± 0.03). Water to feed ratio was significantly higher in G2 than other groups. Turkeys’ foot pad health was significantly better in G4 than in other groups beginning at day 21. In turkeys, platforms with slatted floors that allow for temporary separation of the feet from the litter could lead to improvements in foot pad health which could better enable the realization of species-specific behaviours and activities in littered areas.

  7. Effect of Different Flooring Designs on the Performance and Foot Pad Health in Broilers and Turkeys

    Directory of Open Access Journals (Sweden)

    Bussarakam Chuppava

    2018-05-01

    Full Text Available Litter quality has a significant influence on the performance and foot pad health in poultry. The objective of this study was to evaluate the effects of different types of flooring designs on the performance and foot pad health in fattening broilers and turkeys. Three trials were conducted for each species using a total of 720 Ross 308 broilers and 720 Big 6 turkeys. After day seven, animals were randomly assigned to four groups with three subgroups each: G1—floor pens with litter, G2—floor pens with litter and floor heating, G3—partially-slatted flooring, including a littered area, and G4—fully-slatted flooring with a sand bath (900 cm2. Animals of both species had a significantly higher final body weight at dissection (day 36 after being reared on fully-slatted floors compared to common littered floors. In turkeys, the feed conversion ratio was worse in G4 (1.53 ± 0.04 than in G1 (1.47 ± 0.02 and G2 (1.48 ± 0.03. Water to feed ratio was significantly higher in G2 than other groups. Turkeys’ foot pad health was significantly better in G4 than in other groups beginning at day 21. In turkeys, platforms with slatted floors that allow for temporary separation of the feet from the litter could lead to improvements in foot pad health which could better enable the realization of species-specific behaviours and activities in littered areas.

  8. 30 CFR 785.19 - Surface coal mining and reclamation operations on areas or adjacent to areas including alluvial...

    Science.gov (United States)

    2010-07-01

    ... alluvial valley floor exists if it finds that— (i) Unconsolidated streamlaid deposits holding streams are... on areas or adjacent to areas including alluvial valley floors in the arid and semiarid areas west of....19 Surface coal mining and reclamation operations on areas or adjacent to areas including alluvial...

  9. Survey On Management Systems And Gross Profit Analysis Of ...

    African Journals Online (AJOL)

    Survey On Management Systems And Gross Profit Analysis Of Muturu In Southern Cross River State. ... in muturu rearing for commercial purposes. Cost price of muturu within the study area was uniform due to the influence of market associations. The selling price of muturu cattle is however influenced by the location.

  10. A prospective study of floor surface, shoes, floor cleaning and slipping in US limited-service restaurant workers.

    Science.gov (United States)

    Verma, Santosh K; Chang, Wen Ruey; Courtney, Theodore K; Lombardi, David A; Huang, Yueng-Hsiang; Brennan, Melanye J; Mittleman, Murray A; Ware, James H; Perry, Melissa J

    2011-04-01

    Slips and falls are a leading cause of injury at work. Few studies, however, have systematically examined risk factors of slipping outside the laboratory environment. This study examined the association between floor surface characteristics, slip-resistant shoes, floor cleaning frequency and the risk of slipping in limited-service restaurant workers. 475 workers from 36 limited-service restaurants from three major chains in six states in the USA were recruited to participate in a prospective cohort study of workplace slipping. Kitchen floor surface roughness and coefficient of friction (COF) were measured in eight working areas and then averaged within each restaurant. The use of slip-resistant shoes was determined by examining the participant's shoes and noting the presence of a 'slip-resistant' marking on the sole. Restaurant managers reported the frequency of daily kitchen floor cleaning. Participants reported their slip experience and work hours weekly for up to 12 weeks. The survey materials were made available in three languages: English, Spanish and Portuguese. The associations between rate of slipping and risk factors were assessed using a multivariable negative binomial generalised estimating equation model. The mean of individual slipping rate varied among the restaurants from 0.02 to 2.49 slips per 40 work hours. After adjusting for age, gender, BMI, education, primary language, job tenure and restaurant chain, the use of slip-resistant shoes was associated with a 54% reduction in the reported rate of slipping (95% CI 37% to 64%), and the rate of slipping decreased by 21% (95% CI 5% to 34%) for each 0.1 increase in the mean kitchen COF. Increasing floor cleaning frequency was significantly associated with a decreasing rate of slipping when considered in isolation but not after statistical adjustment for other factors. These results provide support for the use of slip-resistant shoes and measures to increase COF as preventive interventions to reduce slips

  11. Pilot cluster randomised controlled trial of flooring to reduce injuries from falls in elderly care units: study protocol.

    Science.gov (United States)

    Drahota, Amy; Gal, Diane; Windsor, Julie; Dixon, Simon; Udell, Julie; Ward, Derek; Soilemezi, Dia; Dean, Taraneh; Severs, Martin

    2011-12-01

    Falls are an issue disproportionately affecting older people who are at increased risk of falls and injury. This protocol describes a pilot study investigating shock-absorbing flooring for fall-related injuries in wards for older people. To inform future research by evaluating fall-related injuries on the intervention and existing flooring, assessing the sustainability of the flooring in ward environments, estimating the cost-effectiveness of the floor and assessing how the floor affects patients and other users. This study uses mixed methods a pilot cluster randomised controlled trial, observation via mechanical testing and interviews. Eight participating wards (clusters) are randomised using a computer-generated list. No blinding is incorporated into the study. Each site has a baseline period of approximately 6 months. Then, four sites receive the intervention floor, while four continue using standard floors. Sites are then followed up for approximately 1 year. Any person admitted to a bed in the 'study area' of a participating ward can be entered into the trial. Orientated patients, visitors and any hospital staff who use the floor in a study area are eligible for inclusion in an interview. An 8.3 mm thick vinyl floor covering with polyvinyl chloride foam backing (Tarkett Omnisports EXCEL). The primary outcome is fall-related injuries. Severity of injuries, falls, cost-effectiveness, user views and mechanical performance (shock absorbency and slip resistance) are also being assessed.

  12. Price floors for emissions trading

    International Nuclear Information System (INIS)

    Wood, Peter John; Jotzo, Frank

    2011-01-01

    Price floors in greenhouse gas emissions trading schemes can guarantee minimum abatement efforts if prices are lower than expected, and they can help manage cost uncertainty, possibly as complements to price ceilings. Provisions for price floors are found in several recent legislative proposals for emissions trading. Implementation however has potential pitfalls. Possible mechanisms are government commitments to buy back permits, a reserve price at auction, or an extra fee or tax on acquittal of emissions permits. Our analysis of these alternatives shows that the fee approach has budgetary advantages and is more compatible with international permit trading than the alternatives. It can also be used to implement more general hybrid approaches to emissions pricing. - Research highlights: → Price floors for emissions trading schemes guarantee a minimum carbon price. → Price floors mean that emissions can be less than specified by the ETS cap. → We examine how price floors can relate to different policy objectives. → We compare different mechanisms for implementing a price floor. → We find that a mechanism where there is an extra tax or fee has advantages.

  13. Myofascial pain and pelvic floor dysfunction in patients with interstitial cystitis.

    Science.gov (United States)

    Bassaly, Renee; Tidwell, Natalie; Bertolino, Siobhan; Hoyte, Lennox; Downes, Katheryne; Hart, Stuart

    2011-04-01

    The objectives of this study are to investigate myofascial pain in patients with interstitial cystitis (IC) and to correlate myofascial exam findings with validated questionnaires. A retrospective chart review was performed on 186 patients with a diagnosis of IC from April 2007 to December 2008. Demographics, history and physical examination, and validated pelvic floor dysfunction questionnaire scores were extracted. The data was evaluated with SPSS for Windows using Spearman's rho, Mann-Whitney, and Kruskal-Wallis statistical analyses. Myofascial pain was demonstrated in 78.3% of IC patients with at least one myofascial trigger point, and 67.9% of patients had numerous areas of trigger points. Mild correlations were seen with trigger points and scores from the PUF, PFDI-20, and PFIQ-7 questionnaires. Myofascial pain is prevalent among IC patients and positively correlated with pelvic floor dysfunction scores. These findings support evaluation of pelvic floor myofascial pain in IC patients and suggest a possible benefit from pelvic floor therapy.

  14. Floor heating systems

    Energy Technology Data Exchange (ETDEWEB)

    Radtke, U

    1984-02-01

    The question of whether PPC- and VPE-floor heating pipes can endure damage when incompletely imbedded in the floor finish is investigated in an experimental setup. An expansion of the pipe, caused by a temperature increase from 20/sup 0/C to 50/sup 0/C was measured and considered too small to deduce the degree of danger from the damage.

  15. Shoe sole tread designs and outcomes of slipping and falling on slippery floor surfaces.

    Directory of Open Access Journals (Sweden)

    Li-Wen Liu

    Full Text Available A gait experiment was conducted under two shoe sole and three floor conditions. The shoe soles and floors were characterized by the tread and groove designs on the surface. The coefficients of friction (COF on the floor in the target area were measured. The subjects were required to walk on a walkway and stepping on a target area covered with glycerol. The motions of the feet of the subjects were captured. Gait parameters were calculated based on the motion data. Among the 240 trials, there were 37 no-slips, 81 microslips, 45 slides, and 77 slips. It was found that the condition with shoe sole and floor had both tread grooves perpendicular to the walking direction had the highest COF, the shortest slip distance, and the lowest percentages of slide and slip. The condition with shoe sole and floor had both tread grooves parallel to the walking direction had the lowest COF and the longest slip distance among all experimental conditions. The Pearson's correlation coefficients between slip distance and slip velocity, time to foot flat, foot angle, and compensatory step length were 0.82 (p<0.0001, 0.33 (p<0.0001, -0.54 (p<0.0001, and -0.51 (p<0.0001, respectively.

  16. Maxillary Sinus Floor Augmentation

    DEFF Research Database (Denmark)

    Starch-Jensen, Thomas; Jensen, Janek Dalsgaard

    2017-01-01

    , radiological and histomorphometric outcome as well as complications are presented after maxillary sinus floor augmentation applying the lateral window technique with a graft material, maxillary sinus membrane elevation without a graft material and osteotome-mediated sinus floor elevation with or without...

  17. The effect of sub-floor heating on house-dust-mite populations on floors and in furniture.

    Science.gov (United States)

    de Boer, Rob

    2003-01-01

    It is well known that dehydrating conditions for house dust mites can be created by simply raising the temperature, causing loss of body water and eventually death. Thus, it can be expected that conditions for dust mites are less favourable on floors supplied with sub-floor heating. This was examined in a study of 16 houses with sub-floor heating and 21 without. The pattern of changes in air humidity and temperature on the floors was investigated and compared to known data of the tolerance of dust mites. Also the resident mite populations were compared. Floors with sub-floor heating had, on average, fewer mites, but the difference with unheated floors was small. It was remarkable that mite numbers were also lower in upholstered furniture. Another important observation was that some houses with sub-floor heating had high mite numbers, indicating that this type of heating is compatible with a thriving mite population. Temperature and humidity conditions of heated floors may allow mites not only to survive, but also to remain active in winter. A moderate increase in temperature, a moderate decrease in (absolute) air humidity, or a combination of both, will suffice to keep the humidity all winter below the Critical Equilibrium Humidity, the level of air humidity that is critical for mite growth and reproduction, hence for allergen production. However, it is argued that measures to suppress allergen production by house dust mites are likely to be far more effective if taken in summer rather than in winter.

  18. The estimation of sea floor dynamics from bathymetric surveys of a sand wave area

    NARCIS (Netherlands)

    Dorst, Leendert; Roos, Pieter C.; Hulscher, Suzanne J.M.H.; Lindenbergh, R.C.

    2009-01-01

    The analysis of series of offshore bathymetric surveys provides insight into the morphodynamics of the sea floor. This knowledge helps to improve resurvey policies for the maintenance of port approaches and nautical charting, and to validate morphodynamic models. We propose a method for such an

  19. Innovative procedure for the determination of gross-alpha/gross-beta activities in drinking water

    International Nuclear Information System (INIS)

    Wisser, S.; Frenzel, E.; Dittmer, M.

    2006-01-01

    An alternative sample preparation method for the determination of gross-alpha/beta activity concentrations in drinking water is introduced in this paper. After the freeze-drying of tap water samples, determination by liquid scintillation counting can be applied utilizing alpha/beta separation. It has been shown that there is no adsorption or loss of solid radionuclides during the freeze-drying procedure. However, the samples have to be measured quickly after the preparation since the ingrowth of daughter isotopes negatively effects the measurement. The limits of detection for gross-alpha and gross-beta activity are in the range 25-210 mBq/l, respectively, for a measurement time of only 8-9 h

  20. Validating the Rett Syndrome Gross Motor Scale

    DEFF Research Database (Denmark)

    Downs, Jenny; Stahlhut, Michelle; Wong, Kingsley

    2016-01-01

    .93-0.98). The standard error of measurement for the total score was 2 points and we would be 95% confident that a change 4 points in the 45-point scale would be greater than within-subject measurement error. The Rett Syndrome Gross Motor Scale could be an appropriate measure of gross motor skills in clinical practice......Rett syndrome is a pervasive neurodevelopmental disorder associated with a pathogenic mutation on the MECP2 gene. Impaired movement is a fundamental component and the Rett Syndrome Gross Motor Scale was developed to measure gross motor abilities in this population. The current study investigated...... the validity and reliability of the Rett Syndrome Gross Motor Scale. Video data showing gross motor abilities supplemented with parent report data was collected for 255 girls and women registered with the Australian Rett Syndrome Database, and the factor structure and relationships between motor scores, age...

  1. Linear Alkylbenzenesulfonates in indoor Floor Dust

    DEFF Research Database (Denmark)

    Madsen, Jørgen Øgaard; Wolkoff, Peder; Madsen, Jørgen Øgaard

    1999-01-01

    The amount of Linear Alkylbenzenesulfonates (LAS) in the particle fraction of floor dust sampled from 7 selected public buildings varied between 34 and 1500 microgram per gram dust, while the contents of the fibre fractions generally were higher with up to 3500 microgram LAS/g dust. The use...... of a cleaning agent with LAS resulted in an increase of the amount of LAS in the floor dust after floor wash relative to just before floor wash. However, the most important source of LAS in the indoor floor dust appears to be residues of detergent in clothing. Thus, a newly washed shirt contained 2960 microgram...

  2. A survey of gross alpha and gross beta activity in soil samples in Kinta District, Perak, Malaysia

    International Nuclear Information System (INIS)

    Lee, Siak Kuan; Wagiran, Husin; Ramli, Ahmad Termizi

    2014-01-01

    The objective of this study was to determine the gross alpha and gross beta activity concentrations from the different soil types found in the Kinta District, Perak, Malaysia. A total of 128 soil samples were collected and their dose rates were measured 1 m above the ground. Gross alpha and gross beta activity measurements were carried out using gas flow proportional counter, Tennelec Series 5 LB5500 Automatic Low Background Counting System. The alpha activity concentration ranged from 15 to 9634 Bq kg -1 with a mean value of 1558±121 Bq kg -1 . The beta activity concentration ranged from 142 to 6173 Bq kg -1 with a mean value of 1112±32 Bq kg -1 . High alpha and beta activity concentrations are from the same soil type. The results of the analysis show a strong correlation between the gross alpha activity concentration and dose rate (R = 0.92). The data obtained can be used as a database for each soil type. (authors)

  3. Effects of Floor Covering Resistance of a Radiant Floor on System Energy and Exergy Performances

    DEFF Research Database (Denmark)

    Kazanci, Ongun Berk; Shukuya, Masanori; Olesen, Bjarne W.

    2016-01-01

    Floor covering resistance (material and thickness) can be influenced by subjective choices (architectural design, interior design, texture, etc.) with significant effects on the performance of a radiant heating and cooling system. To study the effects of floor covering resistance on system...... performance, a water-based radiant floor heating and cooling system (dry, wooden construction) was considered to be coupled to an air-to-water heat pump, and the effects of varying floor covering resistances (0.05 m2K/W, 0.09 m2K/W and 0.15 m2K/W) on system performance were analyzed in terms of energy...... and exergy. In order to achieve the same heating and cooling outputs, higher average water temperatures are required in the heating mode (and lower temperatures in the cooling mode) with increasing floor covering resistance. These temperature requirements decrease the heat pump’s performance (lower...

  4. A comparative study on thermal efficiency between the present floor and a ceramic floor

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Y.M.; Kim, K.S. [Korea Institute of Science and Technology, Seoul (Korea, Republic of); Choi, B.S. [Kyung Hee University, Yongin (Korea, Republic of); Ko, J.S.; Park, S.K. [Bomwoo and Co. LTD., Kwangju (Korea, Republic of)

    1999-04-01

    A ceramic floor with improved thermal conductivity and efficiency has been developed in this study. The new ceramic floor minimizes the shrinkage rate to below 0.07% and shows almost no cleavage. There is no need to repair the ceramic floor because its bottom surface is flat. It especially shows an excellent performance in the test of a compressive strength (300 kg/cm{sup 2} based on 28 days), a flexural strength (64 kg/cm{sup 2} based on 28 days), and a convenient pressing. It is lighter than the present floor and it is expected to be applicable for a self-leveling ceramic motar in the residences and apartments. It shows an excellent character in the thermal conductivity and other physical properties compare to the present cement mortar. 5 refs., 3 figs., 2 tabs.

  5. Floors: Care and Maintenance.

    Science.gov (United States)

    Post Office Dept., Washington, DC.

    Guidelines, methods and policies regarding the care and maintenance of post office building floors are overviewed in this handbook. Procedures outlined are concerned with maintaining a required level of appearance without wasting manpower. Flooring types and characteristics and the particular cleaning requirements of each type are given along with…

  6. Successful surgical treatment of intractable hemifacial spasm: A case report and review of cerebellar hamartomas of the floor of the fourth ventricle

    Directory of Open Access Journals (Sweden)

    Joseph H. Miller

    2016-12-01

    Full Text Available Introduction: Hamartomas involving the floor of the fourth ventricle and cerebellum are rare, but can be associated with medically recalcitrant hemifacial spasm. These lesions present early in the neonatal or infantile period and respond well to surgical excision. Case Report: A 3-month-old white male presented with recurrent left hemifacial spasm, left eye deviation, and absent movement of the extremities. The patient was found to have a left eccentric lesion in the floor of the fourth ventricle and cerebellum. The patient showed no improvement with medical therapy by 6 months of age. He was taken to the operating room for suboccipital craniotomy and removal of the posterior arch of C1 followed by intralesional recording of epileptogenic activity and gross total resection of the lesion. After histologic analysis, the lesion was determined to be ectopic cerebral tissue consistent with a hamartoma. Postoperative MRI showed complete removal of the lesion, and the patient exhibited complete remission of his hemifacial spasm and associated symptoms. Conclusions: Hamartomas involving the floor of the fourth ventricle can present with hemifacial spasm and respond well to surgical excision. Keywords: Cerebellar, Seizure, Epilepsy, Hamartoma

  7. Development of a Computerized Adaptive Test of Children's Gross Motor Skills.

    Science.gov (United States)

    Huang, Chien-Yu; Tung, Li-Chen; Chou, Yeh-Tai; Wu, Hing-Man; Chen, Kuan-Lin; Hsieh, Ching-Lin

    2018-03-01

    To (1) develop a computerized adaptive test for gross motor skills (GM-CAT) as a diagnostic test and an outcome measure, using the gross motor skills subscale of the Comprehensive Developmental Inventory for Infants and Toddlers (CDIIT-GM) as the candidate item bank; and (2) examine the psychometric properties and the efficiency of the GM-CAT. Retrospective study. A developmental center of a medical center. Children with and without developmental delay (N=1738). Not applicable. The CDIIT-GM contains 56 universal items on gross motor skills assessing children's antigravity control, locomotion, and body movement coordination. The item bank of the GM-CAT had 44 items that met the dichotomous Rasch model's assumptions. High Rasch person reliabilities were found for each estimated gross motor skill for the GM-CAT (Rasch person reliabilities =.940-.995, SE=.68-2.43). For children aged 6 to 71 months, the GM-CAT had good concurrent validity (r values =.97-.98), adequate to excellent diagnostic accuracy (area under receiver operating characteristics curve =.80-.98), and moderate to large responsiveness (effect size =.65-5.82). The averages of items administered for the GM-CAT were 7 to 11, depending on the age group. The results of this study support the use of the GM-CAT as a diagnostic and outcome measure to estimate children's gross motor skills in both research and clinical settings. Copyright © 2017 American Congress of Rehabilitation Medicine. Published by Elsevier Inc. All rights reserved.

  8. An experimental investigation of composite floor vibration due to human activities. A case study

    Directory of Open Access Journals (Sweden)

    Yasser G. Mohamed Fahmy

    2012-12-01

    Full Text Available Composite steel floor decks are used in a large variety of constructions with long spans, such as administration and commercial buildings, hotels and bridges. Due to decreased floor mass and longer span lengths, floor vibrations have become an area of concern. Floor decks with low frequencies may be in resonance with the vibrations due to human activities and the resulting acceleration may exceed human comfort levels. The design of slender floor structures, with steel or composite cross sections, is often limited by the serviceability criteria such as deflection limits and vibration behavior, rather than the strength criteria. Control of deflections under AISC specifications requirement is not enough to satisfy the serviceability requirements of the floor systems for vibration. In addition, vibration analysis procedures introduced by AISC design Guide No. 11 are based on regularly-shaped structures and simple boundary conditions. In this paper, a case study for full scale testing of a composite floor system proposed for a tower at Kuwait state that was tested prior to construction. The heel-drop and walking tests are performed on floor systems with and without raised floor respectively. Since heel-drop and walking test results would vary in light of person performance, both tests are carried out three or four times to reduce uncertainty. The fundamental frequencies and damping ratio of the floor system are measured. Comparison of the experimental results with results based on the AISC hand calculations shows that there is no significant difference; therefore the results based on AISC are generally acceptable.

  9. NM Gross Receipts January - June 2012

    Data.gov (United States)

    Earth Data Analysis Center, University of New Mexico — This layer represents boundaries for New Mexico's gross receipts tax districts as identified on the "Gross Receipts Tax Rate Schedule" published by the Taxation and...

  10. NM Gross Receipts July - December 2013

    Data.gov (United States)

    Earth Data Analysis Center, University of New Mexico — This layer represents boundaries for New Mexico's gross receipts tax districts as identified on the "Gross Receipts Tax Rate Schedule" published by the Taxation and...

  11. NM Gross Receipts January - June 2014

    Data.gov (United States)

    Earth Data Analysis Center, University of New Mexico — This layer represents boundaries for New Mexico's gross receipts tax districts as identified on the "Gross Receipts Tax Rate Schedule" published by the Taxation and...

  12. NM Gross Receipts July - December 2012

    Data.gov (United States)

    Earth Data Analysis Center, University of New Mexico — This layer represents boundaries for New Mexico's gross receipts tax districts as identified on the "Gross Receipts Tax Rate Schedule" published by the Taxation and...

  13. NM Gross Receipts January - June 2013

    Data.gov (United States)

    Earth Data Analysis Center, University of New Mexico — This layer represents boundaries for New Mexico's gross receipts tax districts as identified on the "Gross Receipts Tax Rate Schedule" published by the Taxation and...

  14. NM Gross Receipts January - June 2011

    Data.gov (United States)

    Earth Data Analysis Center, University of New Mexico — This layer represents boundaries for New Mexico's gross receipts tax districts as identified on the "Gross Receipts Tax Rate Schedule" published by the Taxation and...

  15. Impact of vaginal parity and aging on the architectural design of pelvic floor muscles.

    Science.gov (United States)

    Alperin, Marianna; Cook, Mark; Tuttle, Lori J; Esparza, Mary C; Lieber, Richard L

    2016-09-01

    Vaginal delivery and aging are key risk factors for pelvic floor muscle dysfunction, which is a critical component of pelvic floor disorders. However, alterations in the pelvic floor muscle intrinsic structure that lead to muscle dysfunction because of childbirth and aging remain elusive. The purpose of this study was to determine the impact of vaginal deliveries and aging on human cadaveric pelvic floor muscle architecture, which is the strongest predictor of active muscle function. Coccygeus, iliococcygeus, and pubovisceralis were obtained from younger donors who were ≤51 years old, vaginally nulliparous (n = 5) and vaginally parous (n = 6) and older donors who were >51 years old, vaginally nulliparous (n = 6) and vaginally parous (n = 6), all of whom had no history of pelvic floor disorders. Architectural parameters, which are predictive of muscle's excursion and force-generating capacity, were determined with the use of validated methods. Intramuscular collagen content was quantified by hydroxyproline assay. Main effects of parity and aging and the interactions were determined with the use of 2-way analysis of variance, with Tukey's post-hoc testing and a significance level of .05. The mean age of younger and older donors differed by approximately 40 years (P = .001) but was similar between nulliparous and parous donors within each age group (P > .9). The median parity was 2 (range, 1-3) in younger and older vaginally parous groups (P = .7). The main impact of parity was increased fiber length in the more proximal coccygeus (P = .03) and iliococcygeus (P = .04). Aging changes manifested as decreased physiologic cross-sectional area across all pelvic floor muscles (P < .05), which substantially exceeded the age-related decline in muscle mass. The physiologic cross-sectional area was lower in younger vaginally parous, compared with younger vaginally nulliparous, pelvic floor muscles; however, the differences did not reach statistical significance

  16. Building with electromagnetic shield structure for individual floors

    International Nuclear Information System (INIS)

    Takahashi, T.; Nakamura, M.; Yabana, Y.; Ishikawa, T.; Nagata, K.

    1991-01-01

    This invention relates to a building having a floor-by-floor electromagnetic shield structure well-suited for application to an information network system in which an electromagnetically shielded space is divided by individual floors and electric waves are utilized within the building on a floor-by-floor basis. (author). 8 figs

  17. Building with electromagnetic shield structure for individual floors

    Energy Technology Data Exchange (ETDEWEB)

    Takahashi, T; Nakamura, M; Yabana, Y; Ishikawa, T; Nagata, K

    1991-09-10

    This invention relates to a building having a floor-by-floor electromagnetic shield structure well-suited for application to an information network system in which an electromagnetically shielded space is divided by individual floors and electric waves are utilized within the building on a floor-by-floor basis. (author). 8 figs.

  18. Sea-Floor geology and character of Eastern Rhode Island Sound West of Gay Head, Massachusetts

    Science.gov (United States)

    Poppe, L.J.; McMullen, K.Y.; Ackerman, S.D.; Blackwood, D.S.; Irwin, B.J.; Schaer, J.D.; Forrest, M.R.

    2011-01-01

    Gridded multibeam bathymetry covers approximately 102 square kilometers of sea floor in eastern Rhode Island Sound west of Gay Head, Massachusetts. Although originally collected for charting purposes during National Oceanic and Atmospheric Administration hydrographic survey H11922, these acoustic data and the sea-floor stations subsequently occupied to verify them (1) show the composition and terrain of the seabed, (2) provide information on sediment transport and benthic habitat, and (3) are part of an expanding series of studies that provide a fundamental framework for research and management activities (for example, windfarms and fisheries) along the Massachusetts inner continental shelf. Most of the sea floor in the study area has an undulating to faintly rippled appearance and is composed of bioturbated muddy sand, reflecting processes associated with sediment sorting and reworking. Shallower areas are composed of rippled sand and, where small fields of megaripples are present, indicate sedimentary environments characterized by processes associated with coarse bedload transport. Boulders and gravel were found on the floors of scour depressions and on top of an isolated bathymetric high where erosion has removed the Holocene marine sediments and exposed the underlying relict lag deposits of Pleistocene drift. The numerous scour depressions, which formed during storm-driven events, result in the juxtaposition of sea-floor areas with contrasting sedimentary environments and distinct gravel, sand, and muddy sand textures. This textural heterogeneity in turn creates a complex patchwork of habitats. Our observations of local variations in community structure suggest that this small-scale textural heterogeneity adds dramatically to the sound-wide benthic biological diversity.

  19. What Will Science Gain From Mapping the World Ocean Floor?

    Science.gov (United States)

    Jakobsson, M.

    2017-12-01

    It is difficult to estimate how much of the World Ocean floor topography (bathymetry) that has been mapped. Estimates range from a few to more than ten percent of the World Ocean area. The most recent version of the bathymetric grid compiled by the General Bathymetric Chart of the Oceans (GEBCO) has bathymetric control points in 18% of the 30 x 30 arc second large grid cells. The depth values for the rest of the cells are obtained through interpolation guided by satellite altimetry in deep water. With this statistic at hand, it seems tenable to suggest that there are many scientific discoveries to be made from a complete high-resolution mapping of the World Ocean floor. In this presentation, some of our recent scientific discoveries based on modern multibeam bathymetric mapping will be highlighted and discussed. For example, how multibeam mapping provided evidence for a km-thick ice shelf covering the entire Arctic Ocean during peak glacial conditions, a hypothesis proposed nearly half a century ago, and how groundwater escape features are visible in high-resolution bathymetry in the Baltic Sea, with potential implications for the freshwater budget and distribution of nutrients and pollutants. Presented examples will be placed in the context of mapping resolution, systematic surveys versus mapping along transits, and scientific hypothesis driven mapping versus ocean exploration. The newly announced Nippon Foundation - GEBCO Seabed 2030 project has the vision to map 100% of the World Ocean floor mapped by 2030. Are there specific scientific areas where we can expect new discoveries from all mapping data collected through the Seabed 2030 project? Are there outstanding hypothesis that can be tested from a fully mapped World Ocean floor?

  20. Comparative study on the physico-mechanical characteristics for five types of wood flooring

    Directory of Open Access Journals (Sweden)

    Gabriela CĂLĂTAN

    2014-12-01

    Full Text Available During the period 1600-1700, the first works with parquet elements at Versailles Palace were performed, but the high cost has made that the wooden floor to be an exclusivist product for a long time. Currently, in the last 30 years, the most innovations in flooring industry were aimed to improve the technological process, the easing of work, to reduce the losses of raw materials and to reduce the production costs. The experimental research conducted worldwide has shown that the wood processing technology, up to the flooring finite element, plays an important role in achieving a superior quality and durability and that the finishing systems have to be applied depending on the conditions of the area of use. This paper is a comparative study regarding the physico-mechanical characteristics for five types of wood flooring manufactured and marketed in Romania. In the experimental research, there were analyzed: the behavior of the floor assemblies under linearly distributed and concentrated loads, the thermal insulation characteristics and the slip resistance. The experimental results have shown that these characteristics are influenced by the wood species, the type of product (massive one or subjected to stratification technological processing, the thickness of lamellar flooring elements, and the chosen finishing method (varnishing, oiling.

  1. Get Kids Moving: Simple Activities To Build Gross-Motor Skills.

    Science.gov (United States)

    Texas Child Care, 2003

    2003-01-01

    Highlights the importance of activities to build gross motor skills and provides hints for encouraging such activities. Specific areas of activities presented are: (1) running and jumping; (2) music games; (3) action games; (4) races; (5) bed sheets or parachutes; (6) hula hoops; (7) balls; (8) batting; (9) balance; and (10) creative movement. (SD)

  2. Microstructure of gross chill-mark defect in a glass-ceramic preform

    International Nuclear Information System (INIS)

    Spears, R.K.

    1980-01-01

    The microstructure of a vacuum tube glass-ceramic preform containing gross chill-marks on the top and bottom surfaces as well as on the sides was analyzed. The preform was ceramed in a graphite mold and examined using SEM. The glass-ceramic had an extremely dense and fine crystalline structure except where the chill-marks were located. In those areas of matrix glass following the chill-mark plane were evident. It is concluded that gross chill-marks will affect the microstructure by disrupting the chemistry or nucleating characteristics in such a way that a chill-mark regon would appear to be depleted of crystallites. Although the crystallites in this region are larger, the quantity is lower than in the base glass-ceramic. The affected area caused by the chill-mark left a band of matrix glass approximately 100 μ wide. It is believed that planar defects of this size will degrade the mechanical and permeation properties of the glass-ceramic

  3. Simulations of floor cooling system capacity

    International Nuclear Information System (INIS)

    Odyjas, Andrzej; Górka, Andrzej

    2013-01-01

    Floor cooling system capacity depends on its physical and operative parameters. Using numerical simulations, it appears that cooling capacity of the system largely depends on the type of cooling loads occurring in the room. In the case of convective cooling loads capacity of the system is small. However, when radiation flux falls directly on the floor the system significantly increases productivity. The article describes the results of numerical simulations which allow to determine system capacity in steady thermal conditions, depending on the type of physical parameters of the system and the type of cooling load occurring in the room. Moreover, the paper sets out the limits of system capacity while maintaining a minimum temperature of the floor surface equal to 20 °C. The results are helpful for designing system capacity in different type of cooling loads and show maximum system capacity in acceptable thermal comfort condition. -- Highlights: ► We have developed numerical model for simulation of floor cooling system. ► We have described floor system capacity depending on its physical parameters. ► We have described floor system capacity depending on type of cooling loads. ► The most important in the obtained cooling capacities is the type of cooling loads. ► The paper sets out the possible maximum cooling floor system capacity

  4. Formaldehyde and TVOC emission behavior of laminate flooring by structure of laminate flooring and heating condition.

    Science.gov (United States)

    An, Jae-Yoon; Kim, Sumin; Kim, Hyun-Joong

    2011-03-15

    Formaldehyde was measured with a desiccator, a 20 L chamber and the FLEC method. The formaldehyde emission rate from laminate was the highest at 32 °C using the desiccator, which then decreased with time. The formaldehyde emission using the 20 L small chamber and FLEC showed a similar tendency. There was a strong correlation between the formaldehyde and total volatile organic compounds (TVOCs) with both types of floorings using the two different methods. The formaldehyde emission rate and TVOC results were higher when tested using the FLEC method than with the 20 L small chamber method. The emission rate was affected by the joint edge length in laminate flooring. Toluene, ethylbenzene and xylene were the main VOCs emitted from laminate flooring, and there were more unidentified VOCs emitted than identified VOCs. The samples heated with a floor heating system emitted more formaldehyde than those heated using an air circulation system due to the temperature difference between the bottom panel and flooring. The TVOC emission level of the samples was higher when an air circulation system was used than when a floor heating system was used due to the high ventilation rate. Copyright © 2010 Elsevier B.V. All rights reserved.

  5. Crustal Ages of the Ocean Floor - Poster

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — The Crustal Ages of the Ocean Floor Poster was created at NGDC using the Crustal Ages of the Ocean Floor database draped digitally over a relief of the ocean floor...

  6. Morphological changes after pelvic floor muscle training measured by 3-dimensional ultrasonography: a randomized controlled trial.

    Science.gov (United States)

    Braekken, Ingeborg Hoff; Hoff Braekken, Ingeborg; Majida, Memona; Engh, Marie Ellström; Bø, Kari

    2010-02-01

    To investigate morphological and functional changes after pelvic floor muscle training in women with pelvic organ prolapse. This randomized controlled trial was conducted at a university hospital and a physical therapy clinic. One hundred nine women with pelvic organ prolapse stages I, II, and III were randomly allocated by a computer-generated random number system to pelvic floor muscle training (n=59) or control (n=50). Both groups received lifestyle advice and learned to contract the pelvic floor muscles before and during increases in intraabdominal pressure. In addition the pelvic floor muscle training group did individual strength training with a physical therapist and daily home exercise for 6 months. Primary outcome measures were pelvic floor muscle (pubovisceral muscle) thickness, levator hiatus area, pubovisceral muscle length at rest and Valsalva, and resting position of bladder and rectum, measured by three-dimensional ultrasonography. Seventy-nine percent of women in the pelvic floor muscle training group adhered to at least 80% of the training protocol. Compared with women in the control group, women in the pelvic floor muscle training group increased muscle thickness (difference between groups: 1.9 mm, 95% confidence interval [CI] 1.1-2.7, Ppelvic floor muscle stiffness. Supervised pelvic floor muscle training can increase muscle volume, close the levator hiatus, shorten muscle length, and elevate the resting position of the bladder and rectum. www.clinicaltrials.gov, NCT00271297. I.

  7. 75 FR 66126 - Multilayered Wood Flooring From China

    Science.gov (United States)

    2010-10-27

    ...)] Multilayered Wood Flooring From China AGENCY: United States International Trade Commission. ACTION: Institution... flooring, provided for in subheadings 4409.10, 4409.29, 4412.31, 4412.32, 4412.39, 4412.94, 4412.99, 4418... multilayered wood flooring. The following companies are members of the CAHP: Anderson Hardwood Floors, LLC...

  8. 75 FR 79019 - Multilayered Wood Flooring From China

    Science.gov (United States)

    2010-12-17

    ...)] Multilayered Wood Flooring From China Determinations On the basis of the record \\1\\ developed in the subject... imports from China of multilayered wood flooring, provided for in subheadings 4409.10, 4409.29, 4412.31... multilayered wood flooring. The following companies are members of the CAHP: Anderson Hardwood Floors, LLC...

  9. Mode of delivery and Pelvic floor disorder

    International Nuclear Information System (INIS)

    Noor, R.; Neelam, H.; Bashir, M.S.

    2017-01-01

    Objective: To compare pelvic floor dysfunction in non pregnant women who had delivered vaginally versus those with cesarean delivery. Methodology: The prevalence of pelvic floor disorders among non pregnant women was assesses by using a standardized tool pelvic floor distress inventory short form (PFDI-20). Data was collected from Jinnah Hospital Lahore, Pakistan. Results: Total numbers of participants were 278. 47.12% subjects had moderate, 36.69% miner and 16.19% had severe pelvic floor dysfunction. The symptoms of pelvic organ prolapse were more prevalent (mean value is 59.1876) than Urinary Distress (mean value is 40.5426), while the Colorectal-Anal Distress (mean value is 35.9150) were least prevalent. Conclusion: Pelvic floor disorders are very common among females and are strongly associated with mode of delivery. Although spontaneous vaginal birth was extensively associated with pelvic floor disorders the instrumental delivery affects most. (author)

  10. Monitoring of gross beta radioactivities on water sample environment in the surrounding of kartini reactor at 2011

    International Nuclear Information System (INIS)

    Siswanti; Munandar, A. Aris

    2013-01-01

    Measurement of gross beta radioactivities on water environment were done in the PTAPB BATAN has a goal for routine monitoring, with the result that fill RPL has been made and the result equivalented with quality standard were decided by BAPETEN. The water sample taken as much as 2 liter at 18 area were definited on radius 100 m to 5000 m in the surrounding of kartini reactor, vaporin on electric stove till the volume been ± 10 ml, and than pick out to the aluminium planset and drying on hot plate. Sample in the plancet were counted with a Low Background Counter (LBC) for 30 minutes and accounted of gross beta radioactivity water system. The result of gross beta radioactivity water environment at 2011 has a lowest 009, ± 0,06 Bq/I on Tambak Bayan area at june and in the Janti area highest 0,39 ± 0,08 Bq/ at December. The result still under of quality standard were decided by SK BAPETEN. No. 02/Ka- BAPETEN/V-99 is 0,4 Bq/I. (author)

  11. Functional anatomy of pelvic floor

    Directory of Open Access Journals (Sweden)

    Salvatore Rocca Rossetti

    2016-03-01

    Full Text Available Generally, descriptions of the pelvic floor are discordant, since its complex structures and the complexity of pathological disorders of such structures; commonly the descriptions are sectorial, concerning muscles, fascial developments, ligaments and so on. On the contrary to understand completely nature and function of the pelvic floor it is necessary to study it in the most unitary view and in the most global aspect, considering embriology, philogenesy, anthropologic development and its multiple activities others than urological, gynaecological and intestinal ones. Recent acquirements succeeded in clarifying many aspects of pelvic floor activity, whose musculature has been investigated through electromyography, sonography, magnetic resonance, histology, histochemistry, molecular research. Utilizing recent research concerning not only urinary and gynecologic aspects but also those regarding statics and dynamics of pelvis and its floor, it is now possible to study this important body part as a unit; that means to consider it in the whole body economy to which maintaining upright position, walking and behavior or physical conduct do not share less than urinary, genital, and intestinal functions. It is today possible to consider the pelvic floor as a musclefascial unit with synergic and antagonistic activity of muscular bundles, among them more or less interlaced, with multiple functions and not only the function of pelvic cup closure.

  12. External Hand Forces Exerted by Long-Term Care Staff to Push Floor-Based Lifts: Effects of Flooring System and Resident Weight.

    Science.gov (United States)

    Lachance, Chantelle C; Korall, Alexandra M B; Russell, Colin M; Feldman, Fabio; Robinovitch, Stephen N; Mackey, Dawn C

    2016-09-01

    The aim of this study was to investigate the effects of flooring type and resident weight on external hand forces required to push floor-based lifts in long-term care (LTC). Novel compliant flooring is designed to reduce fall-related injuries among LTC residents but may increase forces required for staff to perform pushing tasks. A motorized lift may offset the effect of flooring on push forces. Fourteen female LTC staff performed straight-line pushes with two floor-based lifts (conventional, motor driven) loaded with passengers of average and 90th-percentile resident weights over four flooring systems (concrete+vinyl, compliant+vinyl, concrete+carpet, compliant+carpet). Initial and sustained push forces were measured by a handlebar-mounted triaxial load cell and compared to participant-specific tolerance limits. Participants rated pushing difficulty. Novel compliant flooring increased initial and sustained push forces and subjective ratings compared to concrete flooring. Compared to the conventional lift, the motor-driven lift substantially reduced initial and sustained push forces and perceived difficulty of pushing for all four floors and both resident weights. Participants exerted forces above published tolerance limits only when using the conventional lift on the carpet conditions (concrete+carpet, compliant+carpet). With the motor-driven lift only, resident weight did not affect push forces. Novel compliant flooring increased linear push forces generated by LTC staff using floor-based lifts, but forces did not exceed tolerance limits when pushing over compliant+vinyl. The motor-driven lift substantially reduced push forces compared to the conventional lift. Results may help to address risk of work-related musculoskeletal injury, especially in locations with novel compliant flooring. © 2016, Human Factors and Ergonomics Society.

  13. 76 FR 76435 - Multilayered Wood Flooring From China

    Science.gov (United States)

    2011-12-07

    ...)] Multilayered Wood Flooring From China Determinations On the basis of the record \\1\\ developed in the subject... multilayered wood flooring, provided for in subheadings 4409.10, 4409.29, 4412.31, 4412.32, 4412.39, 4412.94... flooring. The following companies are members of the CAHP: Anderson Hardwood Floors, LLC, Fountain Inn, SC...

  14. Placental mesenchymal dysplasia: case report with gross and histological findings.

    Science.gov (United States)

    Toscano, Marcello Pecoraro; Schultz, Regina

    2014-01-01

    Placental mesenchymal dysplasia (PMD) is a rare placental disorder characterized by placental enlargement and areas of abnormal, enlarged, grape-like villi. This condition may resemble a partial hydatidiform mole and may occur associated with Beckwith-Wiedemann syndrome (BWS) or in phenotypically normal fetuses. There were 110 cases reported so far. We describe one case with typical gross and microscopic placental lesions.

  15. Placental mesenchymal dysplasia: case report with gross and histological findings

    OpenAIRE

    Marcello Pecoraro Toscano; Regina Schultz

    2014-01-01

    Placental mesenchymal dysplasia (PMD) is a rare placental disorder characterized by placental enlargement and areas of abnormal, enlarged, grape-like villi. This condition may resemble a partial hydatidiform mole and may occur associated with Beckwith?Wiedemann syndrome (BWS) or in phenotypically normal fetuses. There were 110 cases reported so far. We describe one case with typical gross and microscopic placental lesions.

  16. Sea floor magnetic observatory

    Science.gov (United States)

    Korepanov, V.; Prystai, A.; Vallianatos, F.; Makris, J.

    2003-04-01

    The electromagnetic precursors of seismic hazards are widely accepted as strong evidence of the approaching earthquake or volcano eruption. The monitoring of these precursors are of main interest in densely populated areas, what creates serious problems to extract them at the strong industrial noise background. An interesting possibility to improve signal-to-noise ratio gives the installation of the observation points in the shelf zones near the possible earthquake places, what is fairly possible in most seismically active areas in Europe, e. g. in Greece and Italy. The serious restriction for this is the cost of the underwater instrumentation. To realize such experiments it requires the unification of efforts of several countries (e. g., GEOSTAR) or of the funds of some great companies (e. g., SIO magnetotelluric instrument). The progress in electronic components development as well as the appearance of inexpensive watertight glass spheres made it possible to decrease drastically the price of recently developed sea floor magnetic stations. The autonomous vector magnetometer LEMI-301 for sea bed application is described in the report. It is produced on the base of three-component flux-gate sensor. Non-magnetic housing and minimal magnetism of electronic components enable the instrument to be implemented as a monoblock construction where the electronic unit is placed close to the sensor. Automatic circuit provides convenient compensation of the initial field offset and readings of full value (6 digits) of the measured field. Timing by internal clock provides high accuracy synchronization of data. The internal flash memory assures long-term autonomous data storage. The system also has two-axes tilt measurement system. The methodological questions of magnetometer operation at sea bed were studied in order to avoid two types of errors appearing at such experimental cases. First is sea waving influence and second one magnetometer orientation at its random positioning on

  17. Moisture performance of insulated, raised, wood-frame floors : a study of twelve houses in southern Louisiana

    Science.gov (United States)

    Samuel V. Glass; Charles G. Carll; Jay P. Curole; Matthew D. Voitier

    2010-01-01

    In flood-prone areas, elevating a building’s floor system above the anticipated flood level can significantly limit the extent of property damage associated with flooding. In hot and humid climates, such as the Gulf Coast region, raised floor systems may, however, be at risk for seasonal moisture accumulation, as the majority of residential buildings in such climates...

  18. Radiant Floor Cooling Systems

    DEFF Research Database (Denmark)

    Olesen, Bjarne W.

    2008-01-01

    In many countries, hydronic radiant floor systems are widely used for heating all types of buildings such as residential, churches, gymnasiums, hospitals, hangars, storage buildings, industrial buildings, and smaller offices. However, few systems are used for cooling.This article describes a floor...... cooling system that includes such considerations as thermal comfort of the occupants, which design parameters will influence the cooling capacity and how the system should be controlled. Examples of applications are presented....

  19. Magnetic resonance imaging of pelvic floor dysfunction.

    Science.gov (United States)

    Lalwani, Neeraj; Moshiri, Mariam; Lee, Jean H; Bhargava, Puneet; Dighe, Manjiri K

    2013-11-01

    Pelvic floor dysfunction is largely a complex problem of multiparous and postmenopausal women and is associated with pelvic floor or organ descent. Physical examination can underestimate the extent of the dysfunction and misdiagnose the disorders. Functional magnetic resonance (MR) imaging is emerging as a promising tool to evaluate the dynamics of the pelvic floor and use for surgical triage and operative planning. This article reviews the anatomy and pathology of pelvic floor dysfunction, typical imaging findings, and the current role of functional MR imaging. Copyright © 2013 Elsevier Inc. All rights reserved.

  20. [Continuous improvement of portable domestic pelvic floor neuromuscular electrical stimulation on the pelvic floor function of patients with urinary incontinence].

    Science.gov (United States)

    Sun, Zhijing; Zhu, Lan; Lang, Jinghe; Wang, Wei; Shi, Honghui; Pang, Hongxia; Shi, Xinwen

    2015-12-01

    To evaluate continuous improvement of portable domestic pelvic floor neuromuscular electrical stimulation on the pelvic floor function of patients with stress urinary incontinence after short-term pelvic floor electrophysiological treatment in hospital. Totally 60 women with stress urinary incontinence were recruited for this randomized controlled trial. The control group including a total of 30 patients, only received 4 weeks pelvic floor electrophysiological treatment in the hospital. Family consolidation treatment group (experimental group) including 30 patients, after 4-week treatment in hospital, received 12-week of pelvic floor neuromuscular electrical stimulation using portable electrical stimulator at home under the guidance of doctors. In post-treatment 6 months and 9 months, 1-hour pad test was measured for urine leakage, pelvic floor electrical physiological parameters were assessed, and subjective improvement of symptoms of urinary incontinence were evaluated. All these data were analysed to compare the effect of the two groups. In 9 months after treatment, average change of urine leakage, the control group and experiment group were (75±24)% versus (99±3)%, the difference was statistically significant (Pcontinuous improvement of pelvic floor function.

  1. The effect of pelvic floor physical therapy on sexual function in women complaining dyspareunia

    Directory of Open Access Journals (Sweden)

    Parvin Bastani

    2016-10-01

    Full Text Available Background: Dyspareunia is a pain that is occurs in the genital area before, during or after intercourse and is an important factor for sexual dysfunction. The aim of this study was to evaluate the effect of pelvic floor physical therapy on sexual function and muscle strength and endurance of pelvic floor (as a non-invasive therapy in women with dyspareunia. Methods: In this clinical trial study, 32 women in the age range of 20-50-year-old and sexually active with complaints of dyspareunia, before the investigation were examined in terms of genital health and strength and endurance of the pelvic floor muscles. After the confidence of mental health, patients underwent pelvic floor rehabilitation for 10 sessions during 3 months. After assessment, myofascial release techniques and progressive pelvic floor muscles exercise was performed for patients based on their primary strength. Finally, patients were compared in terms of the severity of dyspareunia, sexual performance status (by using female sexual function index questionnaire, improvement of symptoms, pelvic floor muscle strength and endurance before (first session of physiotherapy and after (after 3 months investigation. Results: In the remaining 32 patients with dyspareunia with a mean age of 38±1.24 years, desire index score 0.95 unit, arousal index score 1.01 unit, lubrication index score 0.67 unit, orgasm index score 0.71 unit, satisfaction index score 1.03 unit, pain index score was increased 1.05 unit, strength index score 2.44 unit, endurance index score 7.06 unit were increased in comparison to before the investigation that showed a significant different with P< 0.0001. Conclusion: According to obtained results, pelvic floor physical therapy had a significant effect in women with dyspareunia. So that the severity of dyspareunia, pelvic floor muscle strength and endurance had clinically significant improvement after pelvic floor physiotherapy.

  2. PVC flooring is related to human uptake of phthalates in infants.

    Science.gov (United States)

    Carlstedt, F; Jönsson, B A G; Bornehag, C-G

    2013-02-01

    Polyvinyl chloride (PVC) flooring material contains phthalates, and it has been shown that such materials are important sources for phthalates in indoor dust. Phthalates are suspected endocrine-disrupting chemicals (EDCs). Consecutive infants between 2 and 6 months old and their mothers were invited. A questionnaire about indoor environmental factors and family lifestyle was used. Urinary metabolites of the phthalates diethyl phthalate (DEP), dibutyl phthalate (DBP), butylbenzyl phthalate (BBzP), and dietylhexyl phthalate (DEHP) were measured in the urine of the children. Of 209 invited children, 110 (52%) participated. Urine samples were obtained from 83 of these. Urine levels of the BBzP metabolite monobenzyl phthalate (MBzP) was significantly higher in infants with PVC flooring in their bedrooms (P flooring material may increase the human uptake of phthalates in infants. Urinary levels of phthalate metabolites during early life are associated with the use of PVC flooring in the bedroom, body area, and the use of infant formula. This study shows that the uptake of phthalates is not only related to oral uptake from, for example, food but also to environmental factors such as building materials. This new information should be considered when designing indoor environment, especially for children. © 2012 John Wiley & Sons A/S.

  3. Validating the Rett Syndrome Gross Motor Scale.

    Science.gov (United States)

    Downs, Jenny; Stahlhut, Michelle; Wong, Kingsley; Syhler, Birgit; Bisgaard, Anne-Marie; Jacoby, Peter; Leonard, Helen

    2016-01-01

    Rett syndrome is a pervasive neurodevelopmental disorder associated with a pathogenic mutation on the MECP2 gene. Impaired movement is a fundamental component and the Rett Syndrome Gross Motor Scale was developed to measure gross motor abilities in this population. The current study investigated the validity and reliability of the Rett Syndrome Gross Motor Scale. Video data showing gross motor abilities supplemented with parent report data was collected for 255 girls and women registered with the Australian Rett Syndrome Database, and the factor structure and relationships between motor scores, age and genotype were investigated. Clinical assessment scores for 38 girls and women with Rett syndrome who attended the Danish Center for Rett Syndrome were used to assess consistency of measurement. Principal components analysis enabled the calculation of three factor scores: Sitting, Standing and Walking, and Challenge. Motor scores were poorer with increasing age and those with the p.Arg133Cys, p.Arg294* or p.Arg306Cys mutation achieved higher scores than those with a large deletion. The repeatability of clinical assessment was excellent (intraclass correlation coefficient for total score 0.99, 95% CI 0.93-0.98). The standard error of measurement for the total score was 2 points and we would be 95% confident that a change 4 points in the 45-point scale would be greater than within-subject measurement error. The Rett Syndrome Gross Motor Scale could be an appropriate measure of gross motor skills in clinical practice and clinical trials.

  4. Sea-floor morphology and sedimentary environments of western Block Island Sound, northeast of Gardiners Island, New York

    Science.gov (United States)

    McMullen, Katherine Y.; Poppe, Lawrence J.; Danforth, William W.; Blackwood, Dann S.; Clos, Andrew R.; Parker, Castle E.

    2014-01-01

    Multibeam-echosounder data, collected during survey H12299 by the National Oceanic and Atmospheric Administration in a 162-square-kilometer area of Block Island Sound, northeast of Gardiners Island, New York, are used along with sediment samples and bottom photography, collected at 37 stations in this area by the U.S. Geological Survey during cruise 2013-005-FA, to interpret sea-floor features and sedimentary environments. These data and interpretations provide important base maps for future studies of the sea floor, focused, for example, on benthic ecology and resource management. The features and sedimentary environments on the sea floor are products of the glacial history and modern tidal regime. Features include bedforms such as sand waves and megaripples, boulders, a large current-scoured depression, exposed glaciolacustrine sediments, and areas of modern marine sediment. Sand covers much of the study area and is often in the form of sand waves and megaripples, which indicate environments characterized by coarse-grained bedload transport. Boulders and gravelly lag deposits, which indicate environments of erosion or nondeposition, are found off the coast of Gardiners Island and on bathymetric highs, probably marking areas where deposits associated with recessional ice-front positions, the northern flank of the terminal moraine, or coastal-plain sediments covered with basal till are exposed. Bottom photographs and video of boulders show that they are commonly covered with sessile fauna. Strong tidal currents have produced the deep scour depression along the northwestern edge of the study area. The eastern side of this depression is armored with a gravel lag. Sea-floor areas characterized by modern marine sediments appear featureless at the 2-meter resolution of the bathymetry and flat to current rippled in the photography. These modern environments are indicative of sediment sorting and reworking.

  5. Placental mesenchymal dysplasia: case report with gross and histological findings

    Directory of Open Access Journals (Sweden)

    Marcello Pecoraro Toscano

    2014-12-01

    Full Text Available Placental mesenchymal dysplasia (PMD is a rare placental disorder characterized by placental enlargement and areas of abnormal, enlarged, grape-like villi. This condition may resemble a partial hydatidiform mole and may occur associated with Beckwith–Wiedemann syndrome (BWS or in phenotypically normal fetuses. There were 110 cases reported so far. We describe one case with typical gross and microscopic placental lesions.

  6. Knowledge of the pelvic floor in nulliparous women

    OpenAIRE

    Neels, Hedwig; Wyndaele, Jean-Jacques; Tjalma, Wiebren A. A.; De Wachter, Stefan; Wyndaele, Michel; Vermandel, Alexandra

    2016-01-01

    [Purpose] Proper pelvic floor function is important to avoid serious dysfunctions including incontinence, prolapse, and sexual problems. The current study evaluated the knowledge of young nulliparous women about their pelvic floor and identified what additional information they wanted. [Subjects and Methods] In this cross-sectional survey, a validated, 36 item questionnaire was distributed to 212 nulliparous women. The questionnaire addressed demography, pelvic floor muscles, pelvic floor dys...

  7. Container floor at high temperatures

    International Nuclear Information System (INIS)

    Reutler, H.; Klapperich, H.J.; Mueller-Frank, U.

    1978-01-01

    The invention describes a floor for container which is stressed at high, changing temperatures and is intended for use in gas-cooled nuclear reactors. Due to the downward cooling gas flow in these types of reactor, the reactor floor is subjected to considerable dimensional changes during switching on and off. In the heating stage, the whole graphite structure of the reactor core and floor expands. In order to avoid arising constraining forces, sufficiently large expansion spaces must be allowed for furthermore restoring forces must be present to close the gaps again in the cooling phase. These restoring forces must be permanently present to prevent loosening of the core cuits amongst one another and thus uncontrollable relative movement. Spring elements are not suitable due to fast fatigue as a result of high temperatures and radiation exposure. It is suggested to have the floor elements supported on rollers whose rolling planes are downwards inclined to a fixed point for support. The construction is described in detail by means of drawings. (GL) [de

  8. Modernization Of Public Space Floor And Its Impact On Area - The Example Of The Kościuszko Square In Białystok

    Directory of Open Access Journals (Sweden)

    Tofiluk Anna

    2015-12-01

    Full Text Available The last 25 years have been in many Polish cities a period of intensive modernization and renewals of the existing public spaces. Most of all the resurfacing of the pavement and changing of street furniture have been held. In many cases, the transformations in the urban areas were integrated with exclusion from traffic. The question arises what criteria architects or landscape architects follow and what design solutions apply. It is also interesting how the new shape of the floor in public spaces (understood here as a pavement and street furniture together can help to create integrating and activating space for residents. And how it can affect the quality of life in a wider area. This article attempts to answer these questions based on new solutions on Kosciuszko Square in Białystok, executed in 2005-2009.

  9. No bulging of floor heating pipes to be expected in case of incomplete floor plastering

    Energy Technology Data Exchange (ETDEWEB)

    Radtke, U

    1983-02-01

    According to advertising slogans floor heating pipes are said to be damaged prematurely by bulges if they are not completely surrounded by flooring plaster. The author has thoroughly dealt with this problem and made the respective measurements. He found out that there are so few bulges occurring that they cannot lead to damages.

  10. Quantum Gross-Pitaevskii Equation

    Directory of Open Access Journals (Sweden)

    Jutho Haegeman, Damian Draxler, Vid Stojevic, J. Ignacio Cirac, Tobias J. Osborne, Frank Verstraete

    2017-07-01

    Full Text Available We introduce a non-commutative generalization of the Gross-Pitaevskii equation for one-dimensional quantum gasses and quantum liquids. This generalization is obtained by applying the time-dependent variational principle to the variational manifold of continuous matrix product states. This allows for a full quantum description of many body system ---including entanglement and correlations--- and thus extends significantly beyond the usual mean-field description of the Gross-Pitaevskii equation, which is known to fail for (quasi one-dimensional systems. By linearizing around a stationary solution, we furthermore derive an associated generalization of the Bogoliubov -- de Gennes equations. This framework is applied to compute the steady state response amplitude to a periodic perturbation of the potential.

  11. Nonlinear coupling analysis of coal seam floor during mining based on FLAC3D

    Institute of Scientific and Technical Information of China (English)

    YAO Duo-xi; XU Ji-ying; LU Hai-feng

    2011-01-01

    Based on the hydro-geological conditions of 1028 mining face in Suntuan Coal Mine, mining seepage strain mechanism of seam floor was simulated by a nonlinear coupling method, which applied fluid-solid coupling analysis module of FLAC3D. The results indicate that the permeability coefficient of adjoining rock changes a lot due to mining. The maximum value reaches 1 379.9 times to the original value, where it is at immediate roof of the mined-out area. According to the analysis on the seepage field, mining does not destroy water resistance of the floor aquiclude. The mining fissure does not conduct lime-stone aquifer, and it is less likely to form damage. The plastic zone does not exactly correspond to the seepage area, and the scope of the altered seepage area is much larger than the plastic zone.

  12. Recognition and Management of Nonrelaxing Pelvic Floor Dysfunction

    OpenAIRE

    Faubion, Stephanie S.; Shuster, Lynne T.; Bharucha, Adil E.

    2012-01-01

    Nonrelaxing pelvic floor dysfunction is not widely recognized. Unlike in pelvic floor disorders caused by relaxed muscles (eg, pelvic organ prolapse or urinary incontinence, both of which often are identified readily), women affected by nonrelaxing pelvic floor dysfunction may present with a broad range of nonspecific symptoms. These may include pain and problems with defecation, urination, and sexual function, which require relaxation and coordination of pelvic floor muscles and urinary and ...

  13. Floor-Fractured Craters through Machine Learning Methods

    Science.gov (United States)

    Thorey, C.

    2015-12-01

    Floor-fractured craters are impact craters that have undergone post impact deformations. They are characterized by shallow floors with a plate-like or convex appearance, wide floor moats, and radial, concentric, and polygonal floor-fractures. While the origin of these deformations has long been debated, it is now generally accepted that they are the result of the emplacement of shallow magmatic intrusions below their floor. These craters thus constitute an efficient tool to probe the importance of intrusive magmatism from the lunar surface. The most recent catalog of lunar-floor fractured craters references about 200 of them, mainly located around the lunar maria Herein, we will discuss the possibility of using machine learning algorithms to try to detect new floor-fractured craters on the Moon among the 60000 craters referenced in the most recent catalogs. In particular, we will use the gravity field provided by the Gravity Recovery and Interior Laboratory (GRAIL) mission, and the topographic dataset obtained from the Lunar Orbiter Laser Altimeter (LOLA) instrument to design a set of representative features for each crater. We will then discuss the possibility to design a binary supervised classifier, based on these features, to discriminate between the presence or absence of crater-centered intrusion below a specific crater. First predictions from different classifier in terms of their accuracy and uncertainty will be presented.

  14. Rules for Adaptive Learning and Assistance on the Shop Floor

    Science.gov (United States)

    Ullrich, Carsten

    2016-01-01

    Today's shop floor, the area of a factory where operatives assemble products, is a complex and demanding work environment. The employed and produced technology becomes ever more complex, and employees are responsible for an increasing amount of tasks. As a consequence, the employee is under constant pressure to solve problems occurring on the shop…

  15. Gross motor skill development of kindergarten children in Japan.

    Science.gov (United States)

    Aye, Thanda; Kuramoto-Ahuja, Tsugumi; Sato, Tamae; Sadakiyo, Kaori; Watanabe, Miyoko; Maruyama, Hitoshi

    2018-05-01

    [Purpose] The purposes of this study were to assess and explore the gender-based differences in gross motor skill development of 5-year-old Japanese children. [Subjects and Methods] This cross-sectional study recruited 60 healthy 5-year-old (third-year kindergarten, i.e., nencho ) children (34 boys, 26 girls) from one local private kindergarten school in Otawara city, Tochigi Prefecture, Japan. Gross motor skills, including six locomotor and six object control skills, were assessed using the test of gross motor development, second edition (TGMD-2). All subjects performed two trials of each gross motor skill, and the performances were video-recorded and scored. Assessment procedures were performed according to the standardized guidelines of the TGMD-2. [Results] The majority of subjects had an average level of overall gross motor skills. Girls had significantly better locomotor skills. Boys had significantly better object control skills. [Conclusion] The gross motor skill development of 5-year-old Japanese children involves gender-based differences in locomotor and object control skills. This study provided valuable information that can be used to establish normative references for the gross motor skills of 5-year-old Japanese children.

  16. Validating the Rett Syndrome Gross Motor Scale.

    Directory of Open Access Journals (Sweden)

    Jenny Downs

    Full Text Available Rett syndrome is a pervasive neurodevelopmental disorder associated with a pathogenic mutation on the MECP2 gene. Impaired movement is a fundamental component and the Rett Syndrome Gross Motor Scale was developed to measure gross motor abilities in this population. The current study investigated the validity and reliability of the Rett Syndrome Gross Motor Scale. Video data showing gross motor abilities supplemented with parent report data was collected for 255 girls and women registered with the Australian Rett Syndrome Database, and the factor structure and relationships between motor scores, age and genotype were investigated. Clinical assessment scores for 38 girls and women with Rett syndrome who attended the Danish Center for Rett Syndrome were used to assess consistency of measurement. Principal components analysis enabled the calculation of three factor scores: Sitting, Standing and Walking, and Challenge. Motor scores were poorer with increasing age and those with the p.Arg133Cys, p.Arg294* or p.Arg306Cys mutation achieved higher scores than those with a large deletion. The repeatability of clinical assessment was excellent (intraclass correlation coefficient for total score 0.99, 95% CI 0.93-0.98. The standard error of measurement for the total score was 2 points and we would be 95% confident that a change 4 points in the 45-point scale would be greater than within-subject measurement error. The Rett Syndrome Gross Motor Scale could be an appropriate measure of gross motor skills in clinical practice and clinical trials.

  17. Comparison of panoramic radiograph with cone-beam computed tomography in assessment of maxillary sinus floor and nasal floor

    Directory of Open Access Journals (Sweden)

    Vijay Kumar Bokkasam

    2015-01-01

    Full Text Available Introduction: Panoramic radiograph is frequently prescribed by dentists for implant planning and, hence, accurate assessment of anatomical structures in panoramic radiograph is of utmost importance. Aims: The aim of the present study is to know the accuracy of panoramic radiograph in assessment of relationship between maxillary sinus floor and posterior teeth roots, and the distance from alveolar crest to nasal floor by comparing it with that of cone-beam computed tomographic (CBCT image. Materials and Methods: Panoramic and CBCT images of 30 patients were analyzed. The topographic relationship of each root of posterior teeth to the maxillary sinus floor was evaluated and classified into three classes. The distance from the peak point on maxillary alveolar crest to nasal floor was measured in panoramic radiograph as well as in CBCT image. All the measurements were made by built-in measurement tools. Results: Class 1 roots in panoramic radiograph showed high agreement (86% with CBCT image, followed by class 0 (76%. There was a significant difference in the measurements of alveolar bone height (ABH in the nasal floor region with a P value of 0.018. Conclusion: Panoramic radiograph is reliable in assessment of nasal floor and maxillary sinus, provided position of the patient, distortion, and the inherent magnification factor are taken into consideration.

  18. The Gross-Llewellyn Smith sum rule

    International Nuclear Information System (INIS)

    Scott, W.G.

    1981-01-01

    We present the most recent data on the Gross-Llewellyn Smith sum rule obtained from the combined BEBC Narrow Band Neon and GGM-PS Freon neutrino/antineutrino experiments. The data for the Gross-Llewellyn Smith sum rule as a function of q 2 suggest a smaller value for the QCD coupling constant parameter Λ than is obtained from the analysis of the higher moments. (author)

  19. 75 FR 78897 - Definition of Omission From Gross Income

    Science.gov (United States)

    2010-12-17

    ... Definition of Omission From Gross Income AGENCY: Internal Revenue Service (IRS), Treasury. ACTION: Final regulations. SUMMARY: This document contains final regulations defining an omission from gross income for... overstatement of basis in a sold asset results in an omission from gross income. The regulations will affect any...

  20. Imaging pelvic floor disorders. 2. rev. ed.

    International Nuclear Information System (INIS)

    Stoker, Jaap; Taylor, Stuart A.; DeLancey, John O.L.

    2008-01-01

    This volume builds on the success of the first edition of imaging pelvic floor disorders and is aimed at those practitioners with an interest in the imaging, diagnosis and treatment of pelvic floor dysfunction. Concise textual information from acknowledged experts is complemented by high-quality diagrams and images to provide a thorough update of this rapidly evolving field. Introductory chapters fully elucidate the anatomical basis underlying disorders of the pelvic floor. State of the art imaging techniques and their application in pelvic floor dysfunction are then discussed in detail. Additions since the first edition include consideration of the effect of aging and new chapters on perineal ultrasound, functional MRI and MRI of the levator muscles. The closing sections of the book describe the modern clinical management of pelvic floor dysfunction, including prolapse, urinary and faecal incontinence and constipation, with specific emphasis on the integration of diagnostic and treatment algorithms. (orig.)

  1. Imaging pelvic floor disorders. 2. rev. ed.

    Energy Technology Data Exchange (ETDEWEB)

    Stoker, Jaap [Amsterdam Univ. (Netherlands). Dept. of Radiology; Taylor, Stuart A. [University College Hospital, London (United Kingdom). Dept. of Specialist X-Ray; DeLancey, John O.L. (eds.) [Michigan Univ., Ann Arbor, MI (United States). L4000 Women' s Hospital

    2008-07-01

    This volume builds on the success of the first edition of imaging pelvic floor disorders and is aimed at those practitioners with an interest in the imaging, diagnosis and treatment of pelvic floor dysfunction. Concise textual information from acknowledged experts is complemented by high-quality diagrams and images to provide a thorough update of this rapidly evolving field. Introductory chapters fully elucidate the anatomical basis underlying disorders of the pelvic floor. State of the art imaging techniques and their application in pelvic floor dysfunction are then discussed in detail. Additions since the first edition include consideration of the effect of aging and new chapters on perineal ultrasound, functional MRI and MRI of the levator muscles. The closing sections of the book describe the modern clinical management of pelvic floor dysfunction, including prolapse, urinary and faecal incontinence and constipation, with specific emphasis on the integration of diagnostic and treatment algorithms. (orig.)

  2. Evaluation of the thermal comfort of ceramic floor tiles

    Directory of Open Access Journals (Sweden)

    Carmeane Effting

    2007-09-01

    Full Text Available In places where people are bare feet, the thermal sensation of cold or hot depends on the environmental conditions and material properties including its microstructure and crustiness surface. The uncomforting can be characterized by heated floor surfaces in external environments which are exposed to sun radiation (swimming polls areas or by cold floor surfaces in internal environments (bed rooms, path rooms. The property named thermal effusivity which defines the interface temperature when two semi-infinite solids are putted in perfect contact. The introduction of the crustiness surface on the ceramic tiles interferes in the contact temperature and also it can be a strategy to obtain ceramic tiles more comfortable. Materials with low conductivities and densities can be obtained by porous inclusion are due particularly to the processing conditions usually employed. However, the presence of pores generally involves low mechanical strength. This work has the objective to evaluate the thermal comfort of ceramics floor obtained by incorporation of refractory raw materials (residue of the polishing of the porcelanato in industrial atomized ceramic powder, through the thermal and mechanical properties. The theoretical and experimental results show that the porosity and crustiness surface increases; there is sensitive improvement in the comfort by contact.

  3. Floor heating maximizes residents` comfort

    Energy Technology Data Exchange (ETDEWEB)

    Tirkkanen, P.; Wikstroem, T.

    1996-11-01

    Storing heat in floors by using economical night-time electricity does not increase the specific consumption of heating. According to studies done by IVO, the optimum housing comfort is achieved if the room is heated mainly by means of floor heating that is evened out by window or ceiling heating, or by a combination of all three forms of heating. (orig.)

  4. 78 FR 30329 - Multilayered Wood Flooring from China

    Science.gov (United States)

    2013-05-22

    ...)] Multilayered Wood Flooring from China AGENCY: United States International Trade Commission. ACTION: Notice of...-1179 (Final) concerning multilayered wood flooring (``MLWF'') from China. For further information... reconsider ``its decision not to investigate domestic producers of hardwood plywood used for flooring'' 2. to...

  5. Pelvic floor function during and after first pregnancy

    NARCIS (Netherlands)

    Brummen, H.J. van

    2006-01-01

    This study evaluated the effects the first pregnancy and childbirth on the pelvic floor. Pregnancy and vaginal delivery can negatively affect pelvic floor function. Micturition symptoms, defecation symptoms and sexual dysfunction are all signs of an impaired pelvic floor function. These symptoms are

  6. Gait of dairy cows on floors with different slipperiness.

    Science.gov (United States)

    Telezhenko, E; Magnusson, M; Bergsten, C

    2017-08-01

    This study assessed the slip resistance of different types of solid flooring in cattle housing using a range of technical tests and gait analysis. Dynamic and static coefficient of friction, skid resistance, and abrasiveness were tested on concrete flooring with a smooth finish, a grooved pattern, or a tamped pattern, acid-resistant mastic asphalt, soft rubber mats, and a worn slatted concrete floor. Coefficients of friction and skid resistance were tested under clean and slurry-soiled conditions. Linear kinematic variables were assessed in 40 cows with trackway measurements after the cows passed over the floors in a straight walk. All gait variables were assessed as deviations from those obtained on the slatted concrete floor, which was used as a baseline. The coefficient of friction tests divided the floors into 3 categories: concrete flooring, which had a low coefficient of friction (0.29-0.41); mastic asphalt flooring, which had medium values (0.38-0.45); and rubber mats, which had high values (0.49-0.57). The highest abrasion (g/10 m) was on the asphalt flooring (4.48), and the concrete flooring with a tamped pattern had significantly higher abrasiveness (2.77) than the other concrete floors (1.26-1.60). Lowest values on the skid-resistance tests (dry/wet) were for smooth concrete (79/35) and mastic asphalt (65/47), especially with a slurry layer on the surface. Gait analysis mainly differentiated floors with higher friction and abrasion by longer strides and better tracking. Step asymmetry was lower on floors with high skid-resistance values. The most secure cow gait, in almost every aspect, was observed on soft rubber mats. Relationships between gait variables and physical floor characteristics ranged from average to weak (partial correlations 0.54-0.16). Thus, none of the physical characteristics alone was informative enough to characterize slip resistance. With reference to gait analysis, the abrasiveness of the hard surfaces was more informative than the

  7. Mapping of multi-floor buildings: A barometric approach

    DEFF Research Database (Denmark)

    Özkil, Ali Gürcan; Fan, Zhun; Xiao, Jizhong

    2011-01-01

    This paper presents a new method for mapping multi5floor buildings. The method combines laser range sensor for metric mapping and barometric pressure sensor for detecting floor transitions and map segmentation. We exploit the fact that the barometric pressure is a function of the elevation......, and it varies between different floors. The method is tested with a real robot in a typical indoor environment, and the results show that physically consistent multi5floor representations are achievable....

  8. Alternative Measure of Wellbeing: Bhutan's Gross National ...

    International Development Research Centre (IDRC) Digital Library (Canada)

    There is growing demand for innovative yet rigorous measures of national wellbeing beyond gross domestic product. In 2008, the Centre for Bhutan Studies - Bhutan's main policy research centre - posted data from a preliminary survey of the country's Gross National Happiness (GNH). The Centre for Bhutan Studies ...

  9. The effect of pelvic floor physical therapy on sexual function in women complaining dyspareunia

    OpenAIRE

    Parvin Bastani; Sakineh Hajebrahimi; Fariba Ghaderi; Zahra Vakilazad; Morteza Ghojazadeh

    2016-01-01

    Background: Dyspareunia is a pain that is occurs in the genital area before, during or after intercourse and is an important factor for sexual dysfunction. The aim of this study was to evaluate the effect of pelvic floor physical therapy on sexual function and muscle strength and endurance of pelvic floor (as a non-invasive therapy) in women with dyspareunia. Methods: In this clinical trial study, 32 women in the age range of 20-50-year-old and sexually active with complaints of dyspareun...

  10. Shop Floor-Level Control of Manufacturing Companies: An Interview Study in Finland

    Directory of Open Access Journals (Sweden)

    Tokola Henri

    2015-02-01

    Full Text Available This paper publishes the results of interviews regarding shop-floor-level control of 18 Finnish manufacturing companies. The interviews had 17 open questions relating to demand characteristics, shop floor-level control issues, production flexibility, inventory control, and potential development areas. In order to get insights from the interviews, this paper analyses the answers from the interviews and categorises them into typical answers. The companies that were interviewed are also categorised as small companies with their own end products, subcontractors, or large companies with their own end products, and the emphasis of the analysis is on how companies differ in their shop floor-level control. The results show that different types of companies have different characteristics. Small companies are characterised by constant workflow, seasonal trends in demand, and the use of forecasts. Subcontractors have great daily variation in their demand and processing times. Large companies tend to focus on inventory issues.

  11. Some Passive Damping Sources on Flooring Systems besides the TMD

    DEFF Research Database (Denmark)

    Pedersen, Lars

    2010-01-01

    Impulsive loads and walking loads can generate problematic structural vibrations in flooring-systems. Measures that may be taken to mitigate the problem would often be to consider the implementation of a tuned mass damper or even more advanced vibration control technologies; this in order to add...... damping to the structure. Basically also passive humans on a floor act as a damping source, but it also turns out from doing system identification tests with a floor strip that a quite simple set-up installed on the floor (cheap and readily at hand) might do a good job in terms of reducing vertical floor...... vibrations for some floors. The paper describes the tests with the floor strip, and the results, in terms of dynamic floor behaviour, are compared with what would be expected had the floor instead been equipped with a tuned mass damper....

  12. Physical oceanographic characteristics influencing the dispersion of dissolved tracers released at the sea floor in selected deep ocean study areas

    International Nuclear Information System (INIS)

    Kupferman, S.L.; Moore, D.E.

    1981-02-01

    Scenarios which follow the development in space and time of the concentration field of a dissolved tracer released at the sea floor are presented for a Pacific and two Atlantic study areas. The scenarios are closely tied to available data by means of simple analytical models and proceed in stages from short time and space scales in the immediate vicinity of a release point to those scales characteristic of ocean basins. The concepts of internal mixing time and residence time in the benthic mixed layer, useful for developing an intuitive feeling for the behavior of a tracer in this feature, are introduced and discussed. We also introduce the concept of domain of occupation, which is useful in drawing distinctions between mixing and stirring in the ocean. From this study it is apparent that reliable estimation of mixing will require careful consideration of the dynamics of the eddy fields in the ocean. Another area in which more information is urgently needed is in the relation of deep isopycnal structure and bottom topography to local near-bottom circulation

  13. 7 CFR 1424.7 - Gross payable units.

    Science.gov (United States)

    2010-01-01

    ... payments (APP), and base production payments (BPP). Repayment rates shall be based on previous payment... 50 gallons of net production increase. (2) For BPP, which will be made on production not eligible for... biodiesel production gross payable units. (3) Adding the APP and BPP to determine biodiesel gross payable...

  14. The Convergent Evolution of Romania’s Gross Domestic Product in Relation to the Average Macro-Economic Result of the European Union Countries

    Directory of Open Access Journals (Sweden)

    Raluca Necula

    2016-08-01

    Full Text Available Romania's economic growth is a target that can be achieved only within the accordance of all the economic sectors with the Europe 2020 Strategy. As provided in the Convergence Programme 2014-2020, this objective entails a series of steps that Romania must rigorously follow in order to be able to ensure a real converge process at the level of developed European Union (EU countries form the Euro Area. This paper aims an overview presentation of the economy synthetized in its major result, respectively in the dynamics of the total Gross Domestic Product (GDP /capita and agricultural Gross Domestic Product (GDP /capita, and it also compares with the level of the EU 28 average and the level of the Euro Area average. There are calculated, using linear and quadratic functions, the Gross Domestic Product GDP trends, and, with the convergence equation, there are calculated the years that separate Romania from the level of other countries, through the application of annual growth rates. The calculations result shows a strong economic boost of Romania, the annual growth rates being high, both for Gross Domestic Product (GDP / capita (US$ and for agricultural Gross Domestic Product (GDP/ capita (US$, but also a pretty big gap between its development level and the EU 28 and the Euro Area average level.

  15. Life cycle inventory of manufacturing prefinished engineered wood flooring in eastern U.S. with comparison to solid strip wood flooring

    Science.gov (United States)

    Richard D. Bergman; Scott A. Bowe

    2011-01-01

    Building products have come under increased scrutiny because of environmental impacts from their manufacture. Our study followed the life cycle inventory approach for prefinished engineered wood flooring in the eastern US and compared the results with those of solid strip wood flooring. Our study surveyed five engineered wood flooring manufacturers in the eastern US....

  16. Experimental Verification of an Instrument to Test Flooring Materials

    Science.gov (United States)

    Philip, Rony; Löfgren, Hans, Dr

    2018-02-01

    The focus of this work is to validate the fluid model with different flooring materials and the measurements of an instrument to test flooring materials and its force attenuating capabilities using mathematical models to describe the signature and coefficients of the floor. The main contribution of the present work focus on the development of a mathematical fluid model for floors. The aim of the thesis was to analyze, compare different floor materials and to study the linear dynamics of falling impacts on floors. The impact of the hammer during a fall is captured by an accelerometer and response is collected using a picoscope. The collected data was analyzed using matlab least square method which is coded as per the fluid model. The finding from this thesis showed that the fluid model works with more elastic model but it doesn’t work for rigid materials like wood. The importance of parameters like velocity, mass, energy loss and other coefficients of floor which influences the model during the impact of falling on floors were identified and a standardized testing method was set.

  17. Patients with Pelvic Floor Muscle Spasm Have a Superior Response to Pelvic Floor Physical Therapy at Specialized Centers.

    Science.gov (United States)

    Polackwich, Alan Scott; Li, Jianbo; Shoskes, Daniel A

    2015-10-01

    Chronic prostatitis/chronic pelvic pain syndrome is a common condition that often requires multimodal therapy. Patients with chronic pelvic pain syndrome have a high incidence of pelvic floor spasm, which can be treated with pelvic floor physical therapy. However, this is a specialized skill. We compared outcomes of pelvic floor physical therapy as part of multimodal therapy in patients with chronic pelvic pain syndrome between those treated at our institution and elsewhere. We identified patients from our chronic pelvic pain syndrome registry with pelvic floor spasm who were seen between 2010 and 2014 for more than 1 visit. Patient phenotype was assessed with the UPOINT system and symptom severity was determined by the National Institutes of Health CPSI. A 6-point decrease in CPSI was used to define patient improvement. A total of 82 patients fit the study criteria. Mean age was 41.6 years (range 19 to 75) and median symptom duration was 24 months (range 3 to 240). Mean CPSI was 26.8 (range 10 to 41), the median number of positive UPOINT domains was 3 (range 1 to 6) and 27 patients (32.9%) were treated locally. At followup 9 patients had refused pelvic floor physical therapy, and 24 and 48 had undergone pelvic floor physical therapy elsewhere and at CCF, respectively. The mean change in CPSI was 1.11 ± 4.1 in patients who refused, -3.46 ± 6.7 in those treated elsewhere and -11.3 ± 7.0 in those treated at CCF (p physical therapy at CCF (OR 4.23, p = 0.002) and symptom duration (OR 0.52, p = 0.03) predicted improvement. Pelvic floor physical therapy can be effective for chronic pelvic pain syndrome in patients with pelvic floor spasm. However, the outcome depends on specialty training and experience of therapists. Copyright © 2015 American Urological Association Education and Research, Inc. Published by Elsevier Inc. All rights reserved.

  18. Investigation of Floor Surface Finishes for Optimal Slip Resistance Performance

    Directory of Open Access Journals (Sweden)

    In-Ju Kim

    2018-03-01

    Full Text Available Background: Increasing the slip resistance of floor surfaces would be desirable, but there is a lack of evidence on whether traction properties are linearly correlated with the topographic features of the floor surfaces or what scales of surface roughness are required to effectively control the slipperiness of floors. Objective: This study expands on earlier findings on the effects of floor surface finishes against slip resistance performance and determines the operative ranges of floor surface roughness for optimal slip resistance controls under different risk levels of walking environments. Methods: Dynamic friction tests were conducted among three shoes and nine floor specimens under wet and oily environments and compared with a soapy environment. Results: The test results showed the significant effects of floor surface roughness on slip resistance performance against all the lubricated environments. Compared with the floor-type effect, the shoe-type effect on slip resistance performance was insignificant against the highly polluted environments. The study outcomes also indicated that the oily environment required rougher surface finishes than the wet and soapy ones in their lower boundary ranges of floor surface roughness. Conclusion: The results of this study with previous findings confirm that floor surface finishes require different levels of surface coarseness for different types of environmental conditions to effectively manage slippery walking environments. Collected data on operative ranges of floor surface roughness seem to be a valuable tool to develop practical design information and standards for floor surface finishes to efficiently prevent pedestrian fall incidents. Keywords: floor surface finishes, operational levels of floor surface roughness, slip resistance, wet, soapy and oily environments

  19. An architecture for agile shop floor control systems

    DEFF Research Database (Denmark)

    Langer, Gilad; Alting, Leo

    2000-01-01

    as shop floor control. This paper presents the Holonic Multi-cell Control System (HoMuCS) architecture that allows for design and development of holonic shop floor control systems. The HoMuCS is a shop floor control system which is sometimes referred to as a manufacturing execution system...

  20. Divergent axial morphogenesis and early shh expression in vertebrate prospective floor plate

    Directory of Open Access Journals (Sweden)

    Stanislav Kremnyov

    2018-01-01

    Full Text Available Abstract Background The notochord has organizer properties and is required for floor plate induction and dorsoventral patterning of the neural tube. This activity has been attributed to sonic hedgehog (shh signaling, which originates in the notochord, forms a gradient, and autoinduces shh expression in the floor plate. However, reported data are inconsistent and the spatiotemporal development of the relevant shh expression domains has not been studied in detail. We therefore studied the expression dynamics of shh in rabbit, chicken and Xenopus laevis embryos (as well as indian hedgehog and desert hedgehog as possible alternative functional candidates in the chicken. Results Our analysis reveals a markedly divergent pattern within these vertebrates: whereas in the rabbit shh is first expressed in the notochord and its floor plate domain is then induced during subsequent somitogenesis stages, in the chick embryo shh is expressed in the prospective neuroectoderm prior to the notochord formation and, interestingly, prior to mesoderm immigration. Neither indian hedgehog nor desert hedgehog are expressed in these midline structures although mRNA of both genes was detected in other structures of the early chick embryo. In X. laevis, shh is expressed at the beginning of gastrulation in a distinct area dorsal to the dorsal blastopore lip and adjacent to the prospective neuroectoderm, whereas the floor plate expresses shh at the end of gastrulation. Conclusions While shh expression patterns in rabbit and X. laevis embryos are roughly compatible with the classical view of “ventral to dorsal induction” of the floor plate, the early shh expression in the chick floor plate challenges this model. Intriguingly, this alternative sequence of domain induction is related to the asymmetrical morphogenesis of the primitive node and other axial organs in the chick. Our results indicate that the floor plate in X. laevis and chick embryos may be initially

  1. Comfort analysis of lightweight floor system

    NARCIS (Netherlands)

    Zegers, S.F.A.J.G.; Herwijnen, van F.; Randall, B.

    2007-01-01

    During the past 60 years, floor systems used in housing and office-buildings in the Netherlands were mostly made of concrete or other similar materials, These floor systems, which can be characterized as heavy, normally posed little problems concerning vibrations. In recent years, in light of

  2. Medical Students' Perception of Problem Areas in Anatomy ...

    African Journals Online (AJOL)

    The ranges of problems were extensive; neuro-anatomy in gross anatomy, slide review in histology, and cardiovascular embryology were amongst the most highlighted areas of concern. Most students attributed the problems in gross anatomy to difficulty with accessing the area during dissection and inability to grasp the ...

  3. Gross Sales Tax Collections

    Data.gov (United States)

    City of Jackson, Mississippi — This data is captured directly from the MS Department of Revenue and specific to the City of Jackson. It is compiled from Gross Sales Tax reported by taxpayers each...

  4. Loovkirjutamist õpetab Philip Gross

    Index Scriptorium Estoniae

    2011-01-01

    T.S. Elioti luulepreemia laureaat Philip Gross on Tallinna Ülikooli talvekooli rahvusvahelise kursuse "Poetry: A Conversation between Words and Silence" läbiviija. Oma seminarides keskendub ta lisaks loovkirjutamisele ka loova lugemise vajadusele

  5. Floor Vibrations - as Induced and Reduced by Humans

    DEFF Research Database (Denmark)

    Pedersen, Lars

    . As for dynamic loads focus is placed on heel impact excitation and actions of jumping people causing floor vibrations. As for interaction between stationary humans and the vibrating floor focus is on modelling humans as oscillating spring-mass-damper systems attached to the floor rather than as simple added mass...

  6. Flooring-systems and their interaction with furniture and humans

    DEFF Research Database (Denmark)

    Frier, Christian; Pedersen, Lars; Andersen, Lars Vabbersgaard

    2017-01-01

    Flooring-system designs may be sensitive in terms of their vibrational performance due the risk that serviceability-limit-state problems may be encountered. For evaluating the vibrational performance of a flooring system at the design stage, decisions must be made by the engineer in charge...... of computations. Passive humans and/or furniture are often present on a floor. Typically, these masses and their way of interacting with the floor mass are ignored in predictions of vibrational behaviour of the flooring system. Utilizing a shell finite-element model, the paper explores and quantifies how non......-structural mass can influence central parameters describing the dynamic behaviour of the flooring system with focus on elevated non-structural mass. © 2017 The Authors. Published by Elsevier Ltd....

  7. Matching Deep Tow Camera study and Sea Floor geochemical characterization of gas migration at the Tainan Ridge, South China Sea

    Science.gov (United States)

    Fan, L. F.; Lien, K. L.; Hsieh, I. C.; Lin, S.

    2017-12-01

    Methane seep in deep sea environment could lead to build up of chemosynthesis communities, and a number of geological and biological anomalies as compare to the surrounding area. In order to examine the linkage between seep anomalies and those at the vicinity background area, and to detail mapping those spatial variations, we used a deep towed camera system (TowCam) to survey seafloor on the Tainan Ridge, Northeastern South China Sea (SCS). The underwater sea floor pictures could provide better spatial variations to demonstrate impact of methane seep on the sea floor. Water column variations of salinity, temperature, dissolved oxygen were applied to delineate fine scale variations at the study area. In addition, sediment cores were collected for chemical analyses to confirm the existence of local spatial variations. Our results show large spatial variations existed as a result of differences in methane flux. In fact, methane is the driving force for the observed biogeochemical variations in the water column, on the sea floor, and in the sediment. Of the area we have surveyed, there are approximately 7% of total towcam survey data showing abnormal water properties. Corresponding to the water column anomalies, underwater sea floor pictures taken from those places showed that chemosynthetic clams and muscles could be identified, together with authigenic carbonate buildups, and bacterial mats. Moreover, sediment cores with chemical anomalies also matched those in the water column and on the sea floor. These anomalies, however, represent only a small portion of the area surveyed and could not be identified with typical (random) coring method. Methane seep, therefore, require tedious and multiple types of surveys to better understand the scale and magnitude of seep and biogeochemical anomalies those were driven by gas migrations.

  8. Use of hyperspectral remote sensing to estimate the gross photosynthesis of agricultural fields

    International Nuclear Information System (INIS)

    Strachan, I.B.; Pattey, E.; Salustro, C.; Miller, J.R.

    2008-01-01

    Optimization of crop growth and yield is achieved through the use of effective management practices. However, transient weather conditions will modify crop growth and yield. To assess crop development it is therefore essential to understand the current crop ecophysiological status. Such information can be monitored continuously using micrometeorological instrumented towers over agricultural surfaces. The spatial coverage of this approach is limited to the upwind area contributing to the flux. Remote sensing becomes key in deriving carbon exchanges and crop vigour over larger spatial areas. Derived from ground-based hyperspectral reflectance measurements from five growing seasons, a relationship between the eddy covariance estimates of gross photosynthesis and the product of the standardized photochemical reflectance index and the integrated modified triangular index was expanded to the field scale through the use of Compact Airborne Spectrographic Imager (CASI) data for corn and wheat over two consecutive seasons in the same field. Imagery-derived maps of gross photosynthesis successfully identified areas of potential stress that were known to be correlated with lower yield. Results were further verified using an independent flux dataset. This approach, modified from previous attempts in natural ecosystems, offers additional promise for managed systems. (author)

  9. Development of floor design response spectra for seismic design of floor-supported equipment or components, Revision 1, February 1978

    International Nuclear Information System (INIS)

    Anon.

    1979-01-01

    This guide presents an acceptable method for developing two horizontal and one vertical floor design response spectra at various floor or other equipment-support locations from the time-history motions resulting from the dynamic analysis of the supporting structure. These floor design response spectra are used in the dynamic analysis of systems or equipment supported at various locations of the supporting structure. Consulation has been provided by the Advisory Committee on Reactor Safeguards

  10. Deflection of resilient materials for reduction of floor impact sound.

    Science.gov (United States)

    Lee, Jung-Yoon; Kim, Jong-Mun

    2014-01-01

    Recently, many residents living in apartment buildings in Korea have been bothered by noise coming from the houses above. In order to reduce noise pollution, communities are increasingly imposing bylaws, including the limitation of floor impact sound, minimum thickness of floors, and floor soundproofing solutions. This research effort focused specifically on the deflection of resilient materials in the floor sound insulation systems of apartment houses. The experimental program involved conducting twenty-seven material tests and ten sound insulation floating concrete floor specimens. Two main parameters were considered in the experimental investigation: the seven types of resilient materials and the location of the loading point. The structural behavior of sound insulation floor floating was predicted using the Winkler method. The experimental and analytical results indicated that the cracking strength of the floating concrete floor significantly increased with increasing the tangent modulus of resilient material. The deflection of the floating concrete floor loaded at the side of the specimen was much greater than that of the floating concrete floor loaded at the center of the specimen. The Winkler model considering the effect of modulus of resilient materials was able to accurately predict the cracking strength of the floating concrete floor.

  11. Decontamination of polyvinylchloride- and rubber type flooring

    International Nuclear Information System (INIS)

    Kunze, S.

    1975-01-01

    These types, fabricated by mixing of the basic components, showed no relation between content of fillers and decontamination results. Decontamination results are partly poorer, if the flooring contains a high concentration of the filler, especially if the latter consists mainly of hydrophilic materials. The coloring of the floorings seems to have no influence on the decontamination but floorings with clearly separated patterns can not be recommended for nuclear facilities. Fabricated by chemical reactions between polymeres, vulcanization materials and fillers, the decontamination results depend definitely from the proper choice of the filler. Flooring types, containing lampblack, graphite, kaoline, barium sulfate and titanium oxide are easy to decontamine. Again, increasing contents of hydrophilic filler cause a fall off in the decontamination results. (orig.) [de

  12. Historical Cavern Floor Rise for All SPR Sites

    Energy Technology Data Exchange (ETDEWEB)

    Moriarty, Dylan Michael [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)

    2016-09-01

    The Strategic Petroleum Reserve (SPR) contains the largest supply is the largest stockpile of government-owned emergency crude oil in the world. The oil is stored in multiple salt caverns spread over four sites in Louisiana and Texas. Cavern infrastructure near the bottom of the cavern can be damaged from vertical floor movement. This report presents a comprehensive history of floor movements in each cavern. Most of the cavern floor rise rates ranged from 0.5-3.5 ft/yr, however, there were several caverns with much higher rise rates. BH103, BM106, and BH105 had the three highest rise rates. Information from this report will be used to better predict future vertical floor movements and optimally place cavern infrastructure. The reasons for floor rise are not entirely understood and should be investigated.

  13. The determination of the national background radioactivity of gross alpha and gross beta in water samples at the PUSPATI site and its neutrons

    International Nuclear Information System (INIS)

    Rahman, M.T.A.

    1983-01-01

    The determination of the natural background radioactivity in water samples has been made at the PUSPATI site and its environs. The study was performed in January 1981 until June 1981. Samples of river, rain and tap water are periodically collected and analyzed in order to determine gross alpha and gross beta activity. In general, the total radioactivity of water is considerably low. The mean concentration of gross alpha in river water and tap water samples are 1.2 +- 0.1 and 0.2 +- 0.1 pCi/ respectively. The level of gross alpha in rain water is however, below the background rate of the detector. The mean concentration of gross beta in river water, tap water and rain water samples are 4.2 +- 0.6, 1.6 +- 0.3, and 1.9 +- 0.3 pCi/ respectively. (author)

  14. Association between preterm labour and pelvic floor muscle function.

    Science.gov (United States)

    Aran, Turhan; Pekgöz, Ipek; Bozkaya, Hasan; Osmanagaoglu, Mehmet A

    2018-03-23

    We hypothesised that the pressure on the cervix increases with advancing gestation and it may lead to a cervical shortening and cause preterm labour in women with weak pelvic floor muscles. The aim of this prospective study was to measure vaginal resting pressure and pelvic floor muscle strength in the first trimester of pregnancy and to investigate their effects on labour. A study was conducted on the pregnant women with a low risk for preterm birth. The pelvic floor muscle strength and vaginal resting pressure were assessed in 320 pregnant women at their first trimester with a vaginal pressure measurement device. Fifty-two pregnant women were hospitalised for tocolytic therapy because of spontaneous preterm labour. Thirty-two of them (10.2%) had a preterm delivery despite the tocolytic therapy. Both the vaginal resting pressure (p = .009, 95%CI: 0.8; 5.9) and the pelvic floor muscle strength (p = .01, 95%CI: 3.5; 13.1) were significantly lower in the women with a preterm labour. Impact statement What is already known on this subject? The pelvic floor muscles have an essential role in continence and provide support to the pelvic organs. They also have an impact on labour. The pelvic floor muscles should distend to allow the passage of the foetus during labour. The rotation and flexion of the foetal head is due to the pelvic floor resistance. The effect of a vaginal birth on the pelvic floor's function is readily understood. On the other hand, the effect of the pelvic floor muscle function on labour is still controversial. What do the results of this study add? This prospective study showed that there is a negative association between the pelvic floor muscle strength and preterm labour. This is the first clinical study indicating that weak pelvic floor muscles may cause a preterm labour. What are the implications of these findings for clinical practice and/or further research? Pelvic floor physical therapy may be an alternative preventive strategy to reduce

  15. Biomechanics of the pelvic floor musculature

    NARCIS (Netherlands)

    Janda, S.

    2006-01-01

    The present thesis was motivated by two main goals. The first research goal of the thesis was to understand the complex biomechanical behaviour of the pelvic floor muscles. The second goal was to study the mechanism of the pelvic organ prolapse (genital prolapse). The pelvic floor in humans is a

  16. Post-fire comparisons of forest floor and soil carbon, nitrogen, and mercury pools with fire severity indices

    Science.gov (United States)

    Randy Kolka; Brian Sturtevant; Philip Townsend; Jessica Miesel; Peter Wolter; Shawn Fraver; Tom DeSutter

    2014-01-01

    Forest fires are important contributors of C, N, and Hg to the atmosphere. In the fall of 2011, a large wildfire occurred in northern Minnesota and we were able to quickly access the area to sample the forest floor and mineral soil for C, N, and Hg pools. When compared with unburned reference soils, the mean loss of C resulting from fire in the forest floor and the...

  17. 26 CFR 1.832-1 - Gross income.

    Science.gov (United States)

    2010-04-01

    ..., except that in the case of a mutual fire insurance company described in § 1.831-1 the amount of single... TAXES Other Insurance Companies § 1.832-1 Gross income. (a) Gross income as defined in section 832(b)(1... approved by the National Convention of Insurance Commissioners, as well as the gain derived from the sale...

  18. Exploring Simple Algorithms for Estimating Gross Primary Production in Forested Areas from Satellite Data

    Directory of Open Access Journals (Sweden)

    Ramakrishna R. Nemani

    2012-01-01

    Full Text Available Algorithms that use remotely-sensed vegetation indices to estimate gross primary production (GPP, a key component of the global carbon cycle, have gained a lot of popularity in the past decade. Yet despite the amount of research on the topic, the most appropriate approach is still under debate. As an attempt to address this question, we compared the performance of different vegetation indices from the Moderate Resolution Imaging Spectroradiometer (MODIS in capturing the seasonal and the annual variability of GPP estimates from an optimal network of 21 FLUXNET forest towers sites. The tested indices include the Normalized Difference Vegetation Index (NDVI, Enhanced Vegetation Index (EVI, Leaf Area Index (LAI, and Fraction of Photosynthetically Active Radiation absorbed by plant canopies (FPAR. Our results indicated that single vegetation indices captured 50–80% of the variability of tower-estimated GPP, but no one index performed universally well in all situations. In particular, EVI outperformed the other MODIS products in tracking seasonal variations in tower-estimated GPP, but annual mean MODIS LAI was the best estimator of the spatial distribution of annual flux-tower GPP (GPP = 615 × LAI − 376, where GPP is in g C/m2/year. This simple algorithm rehabilitated earlier approaches linking ground measurements of LAI to flux-tower estimates of GPP and produced annual GPP estimates comparable to the MODIS 17 GPP product. As such, remote sensing-based estimates of GPP continue to offer a useful alternative to estimates from biophysical models, and the choice of the most appropriate approach depends on whether the estimates are required at annual or sub-annual temporal resolution.

  19. EuroMInd-D: A Density Estimate of Monthly Gross Domestic Product for the Euro Area

    DEFF Research Database (Denmark)

    Proietti, Tommaso; Marczak, Martyna; Mazzi, Gianluigi

    EuroMInd-D is a density estimate of monthly gross domestic product (GDP) constructed according to a bottom–up approach, pooling the density estimates of eleven GDP components, by output and expenditure type. The components density estimates are obtained from a medium-size dynamic factor model...... of a set of coincident time series handling mixed frequencies of observation and ragged–edged data structures. They reflect both parameter and filtering uncertainty and are obtained by implementing a bootstrap algorithm for simulating from the distribution of the maximum likelihood estimators of the model...

  20. Sea-floor geology and character offshore of Rocky Point, New York

    Science.gov (United States)

    Poppe, L.J.; McMullen, K.Y.; Ackerman, S.D.; Blackwood, D.S.; Irwin, B.J.; Schaer, J.D.; Lewit, P.G.; Doran, E.F.

    2010-01-01

    The U.S. Geological Survey (USGS), the Connecticut Department of Environmental Protection, and the National Oceanic and Atmospheric Administration (NOAA) have been working cooperatively to interpret surficial sea-floor geology along the coast of the Northeastern United States. NOAA survey H11445 in eastern Long Island Sound, offshore of Plum Island, New York, covers an area of about 12 square kilometers. Multibeam bathymetry and sidescan-sonar imagery from the survey, as well as sediment and photographic data from 13 stations occupied during a USGS verification cruise are used to delineate sea-floor features and characterize the environment. Bathymetry gradually deepens offshore to over 100 meters in a depression in the northwest part of the study area and reaches 60 meters in Plum Gut, a channel between Plum Island and Orient Point. Sand waves are present on a shoal north of Plum Island and in several smaller areas around the basin. Sand-wave asymmetry indicates that counter-clockwise net sediment transport maintains the shoal. Sand is prevalent where there is low backscatter in the sidescan-sonar imagery. Gravel and boulder areas are submerged lag deposits produced from the Harbor Hill-Orient Point-Fishers Island moraine segment and are found adjacent to the shorelines and just north of Plum Island, where high backscatter is present in the sidescan-sonar imagery.

  1. 9 CFR 91.26 - Concrete flooring.

    Science.gov (United States)

    2010-01-01

    ... 9 Animals and Animal Products 1 2010-01-01 2010-01-01 false Concrete flooring. 91.26 Section 91.26... LIVESTOCK FOR EXPORTATION Inspection of Vessels and Accommodations § 91.26 Concrete flooring. (a) Pens aboard an ocean vessel shall have a 3 inch concrete pavement, proportioned and mixed to give 2000 psi...

  2. Surgical reconstruction of pelvic floor descent: anatomic and functional aspects.

    Science.gov (United States)

    Wagenlehner, F M E; Bschleipfer, T; Liedl, B; Gunnemann, A; Petros, P; Weidner, W

    2010-01-01

    The human pelvic floor is a complex structure and pelvic floor dysfunction is seen frequently in females. This review focuses on the surgical reconstruction of the pelvic floor employing recent findings on functional anatomy. A selective literature research was performed by the authors. Pelvic floor activity is regulated by 3 main muscular forces that are responsible for vaginal tension and suspension of the pelvic floor organs, bladder and rectum. A variety of symptoms can derive from pelvic floor dysfunctions, such as urinary urge and stress incontinence, abnormal bladder emptying, fecal incontinence, obstructive bowel disease syndrome and pelvic pain. These symptoms mainly derive, for different reasons, from laxity in the vagina or its supporting ligaments as a result of altered connective tissue. Pelvic floor reconstruction is nowadays driven by the concept that in case of pelvic floor symptoms, restoration of the anatomy will translate into restoration of the physiology and ultimately improve patients' symptoms. The surgical reconstruction of the anatomy is almost exclusively focused on the restoration of the lax pelvic floor ligaments. Exact preoperative identification of the anatomical lesions is necessary to allow for exact anatomical reconstruction with respect to the muscular forces of the pelvic floor. Copyright 2010 S. Karger AG, Basel.

  3. Restless behavior increases over time, but not with compressibility of the flooring surface, during forced standing at the feed bunk.

    Science.gov (United States)

    Krebs, N; Berry, S L; Tucker, C B

    2011-01-01

    Interest in the use of rubber flooring in freestall barns has increased, but little is known about which design features of these surfaces are important for cattle. In 2 experiments, we evaluated how the type and compressibility of the flooring surface in front of the feed bunk influenced the behavioral response to 4 h of forced standing after morning milking. Two flooring types were compared: rubber and concrete. Rubber was tested at 3 levels of compressibility: 2, 4, and 35 times as compressible as concrete. Four hours of forced standing was evaluated because it mimicked conditions that can occur on dairies, particularly when waiting for artificial insemination or veterinary treatment. The effects of cow weight and hoof surface area, gait score, and hoof health on the response to treatment were evaluated. Restless behavior, as measured by number of steps, almost doubled over the 4h of forced standing, regardless of flooring material. Cows lay down, on average, within 5 min after access to the lying area was provided. These results indicate that the 4 h of forced standing was uncomfortable. No differences in restless behavior were observed in association with the type or compressibility of the flooring surface in front of the feed bunk. Cow size, hoof health, or gait score did not consistently explain the response to the flooring treatments or stepping rate, although these populations of animals were generally healthy. It is unclear if comfort did not differ between the flooring options tested during 4 h of forced standing or if alterative methodology, such as measuring more subtle shifts in weight, is required to assess design features of rubber flooring. Copyright © 2011 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.

  4. Effect of temperate climate tree species on gross ammonification, gross nitrification and N2O formation

    Science.gov (United States)

    Brüggemann, N.; Rosenkranz, P.; Papen, H.; Butterbach-Bahl, K.

    2003-04-01

    Microbial nitrogen turnover processes in the soil, like ammonification, nitrification and denitrification, play an important role in the formation of nitrous oxide (N2O): (i) ammonification, because it releases nitrogen from organic material in the form of ammonium (NH4+), which in turn can serve as substrate for nitrification; (ii) nitrification itself (i.e. the turnover of NH4+ to nitrate, NO3-), during which nitric oxide (NO) and N2O can be released as by-products at varying ratios; (iii) denitrification, in which NO3- serves as electron acceptor and is converted to molecular nitrogen (N2) via NO and N2O as intermediates, that can also be partially lost to the atmosphere. Temperate forest soils are a substantial source of atmospheric N2O contributing up to 10% to the total atmospheric N2O budget. However, this figure is afflicted with a huge uncertainty due to a number of factors governing the soil N2O formation, consumption, release and uptake, which are not fully understood at present. To one of these factors belongs the influence of the tree species on nitrogen turnover processes in the soil and the formation of N trace gases related with them. The aim of the present work was to analyse this tree species effect for the temperate climate region. For this purpose the effect of five different temperate tree species, having the same age and growing on the same soil in direct vicinity to each other, on gross ammonification and gross nitrification as well as on N2O formation was investigated. The trees (common beech, Fagus sylvatica; pedunculate oak, Quercus robur; Norway spruce, Picea abies; Japanese larch, Larix leptolepis; mountain pine, Pinus mugo) were part of a species trial in Western Jutland, Denmark, established in 1965 on a former sandy heathland. Samples from the soil under these five tree species were taken in spring and in summer 2002, respectively, differentiating between organic layer and mineral soil. The gross rates of ammonification as well of

  5. Study of peak broadening effect in floor time histories

    International Nuclear Information System (INIS)

    Soni, R.S.; Kushwaha, H.S.; Mahajan, S.C.; Kakodkar, A.

    1996-01-01

    Seismic design of secondary systems such components and piping is usually carried out by using the floor motions at their support points. These floor motions can be in the form of Floor Response Spectra (FRS) or the Floor Time Histories (FTH). In order to account for the various uncertainties in generating these floor motions, these motions should be peak broadened and smoothened as per the regulatory codes. Presented here in this paper is the methodology to account for such peak broadening effect in the FTH. Results of this study have been compared with the FRS approach and various important conclusions have been arrived at based on the study

  6. MR Imaging of Degenerative Cartilage Lesions of the Knee Joint in Floor Layers and Graphic Designers

    DEFF Research Database (Denmark)

    Rytter, Søren; Thomsen, Birthe Lykke; Christensen, Birgitte Schütt

    2016-01-01

    Introduction: Kneeling work leads to an additional risk of developing knee osteoarthritis (OA). Previous studies have primarily been based on radiography, but radiography is limited by its inability to visualize articular cartilage, in which the earliest signs of OA occur. The objective of this e......Introduction: Kneeling work leads to an additional risk of developing knee osteoarthritis (OA). Previous studies have primarily been based on radiography, but radiography is limited by its inability to visualize articular cartilage, in which the earliest signs of OA occur. The objective...... of this explorative study, based on available data, was to examine the prevalence of magnetic resonance imaging (MRI)-detected knee cartilage lesions in male floor layers exposed to kneeling work, as compared to non-exposed male graphic designers. Methods: MRI of the knees was conducted in 92 floor layers and 49...... tibiofemoral posterior area, the most strained area during kneeling and 2) the total knee. Presence of lesions was compared in floor layers and graphic designers after adjusting for age, BMI, seniority, knee injuries, and sports activity in logistic regression analyses for correlated data, and investigated...

  7. 26 CFR 1.61-3 - Gross income derived from business.

    Science.gov (United States)

    2010-04-01

    ... Section 1.61-3 Internal Revenue INTERNAL REVENUE SERVICE, DEPARTMENT OF THE TREASURY (CONTINUED) INCOME TAX (CONTINUED) INCOME TAXES (CONTINUED) Definition of Gross Income, Adjusted Gross Income, and..., merchandising, or mining business, “gross income” means the total sales, less the cost of goods sold, plus any...

  8. Analysis of an Attached Sunspace with a Thermal Inertia Floor

    Directory of Open Access Journals (Sweden)

    María José Suárez López

    2018-05-01

    Full Text Available An attached sunspace is a partially or fully glazed enclosure, usually located on the first floor, facing south (in the Northern Hemisphere and adjacent to a conditioned room. Because of the length and orientation of the glazed area, the temperature in the sunspace is usually higher than outside the building. As a Trombe–Mitchel wall, the sunspace has a considerable mass that accumulates thermal energy, but in this case the thermal mass is located in the floor. This capacity to accumulate thermal energy confers the attached sunspace features beyond passive insulation. The sunspace studied in this paper is part of an experimental building located in the North of Spain that was built in the frame of the so-called ARFRISOL project. It consists of a south-facing glazed exterior wall with both clear glass and semi-transparent photovoltaic panels, an intermediate space with a thick layer of sand over a concrete floor, and a partially glazed interior wall. In this paper, a three-dimensional computational model has been implemented to analyse the thermal behaviour inside the sunspace. This analysis takes into account, among other factors, the effects of sun position, incident solar irradiation and temperature both inside and outside.

  9. Reaerosolization of Spores from Flooring Surfaces To Assess the Risk of Dissemination and Transmission of Infections.

    Science.gov (United States)

    Paton, Susan; Thompson, Katy-Anne; Parks, Simon R; Bennett, Allan M

    2015-08-01

    The aim of this study was to quantify reaerosolization of microorganisms caused by walking on contaminated flooring to assess the risk to individuals accessing areas contaminated with pathogenic organisms, for example, spores of Bacillus anthracis. Industrial carpet and polyvinyl chloride (PVC) floor coverings were contaminated with aerosolized spores of Bacillus atrophaeus by using an artist airbrush to produce deposition of ∼10(3) to 10(4) CFU · cm(-2). Microbiological air samplers were used to quantify the particle size distribution of the aerosol generated when a person walked over the floorings in an environmental chamber. Results were expressed as reaerosolization factors (percent per square centimeter per liter), to represent the ratio of air concentration to surface concentration generated. Walking on carpet generated a statistically significantly higher reaerosolization factor value than did walking on PVC (t = 20.42; P flooring in order to inform the choice of appropriate respiratory protective equipment and may aid in the selection of the most suitable flooring types for use in health care environments, to reduce aerosol transmission in the event of contamination. Copyright © 2015, American Society for Microbiology. All Rights Reserved.

  10. An Improved Prediction Model for the Impact Sound Level of Lightweight Floors: Introducing Decoupled Floor-Ceiling and Beam-Plate Moment

    DEFF Research Database (Denmark)

    Mosharrof, Mohammad Sazzad; Brunskog, Jonas; Ljunggren, Fredrik

    2011-01-01

    the impact sound pressure level in a receiving room for a coupled floor structure where floor and ceiling are rigidly connected by beams. A theoretical model for predicting the impact sound level for a decoupled floor structure, which has no rigid mechanical connections between the floor and the ceiling......, is developed. An analytical method has been implemented, where a spatial Fourier transform method as well as the Poisson’s sum formula is applied to model transformed plate displacements. Radiated sound power was calculated from these displacements and normalized sound pressure levels were calculated in one...... and is found to be dependent on frequency, showing significant improvement in predicting impact sound level at high frequency region....

  11. Comparison of changes in the mobility of the pelvic floor muscle on during the abdominal drawing-in maneuver, maximal expiration, and pelvic floor muscle maximal contraction.

    Science.gov (United States)

    Jung, Halim; Jung, Sangwoo; Joo, Sunghee; Song, Changho

    2016-01-01

    [Purpose] The purpose of this study was to compare changes in the mobility of the pelvic floor muscle during the abdominal drawing-in maneuver, maximal expiration, and pelvic floor muscle maximal contraction. [Subjects] Thirty healthy adults participated in this study (15 men and 15 women). [Methods] All participants performed a bridge exercise and abdominal curl-up during the abdominal drawing-in maneuver, maximal expiration, and pelvic floor muscle maximal contraction. Pelvic floor mobility was evaluated as the distance from the bladder base using ultrasound. [Results] According to exercise method, bridge exercise and abdominal curl-ups led to significantly different pelvic floor mobility. The pelvic floor muscle was elevated during the abdominal drawing-in maneuver and descended during maximal expiration. Finally, pelvic floor muscle mobility was greater during abdominal curl-up than during the bridge exercise. [Conclusion] According to these results, the abdominal drawing-in maneuver induced pelvic floor muscle contraction, and pelvic floor muscle contraction was greater during the abdominal curl-up than during the bridge exercise.

  12. The influence of flooring on environmental stressors: a study of three flooring materials in a hospital.

    Science.gov (United States)

    Harris, Debra D

    2015-01-01

    Three flooring materials, terrazzo, rubber, and carpet tile, in patient unit corridors were compared for absorption of sound, comfort, light reflectance, employee perceptions and preferences, and patient satisfaction. Environmental stressors, such as noise and ergonomic factors, effect healthcare workers and patients, contributing to increased fatigue, anxiety and stress, decreased productivity, and patient safety and satisfaction. A longitudinal comparative cohort study comparing three types of flooring assessed sound levels, healthcare worker responses, and patient Hospital Consumer Assessment of Healthcare Providers and Systems (HCAHPS) ratings over 42 weeks. A linear mixed model analysis was conducted to determine significant differences between the means for participant responses and objective sound meter data during all three phases of the study. A significant difference was found for sound levels between flooring type for equivalent continuous sound levels. Carpet tile performed better for sound attenuation by absorption, reducing sound levels 3.14 dBA. Preferences for flooring materials changed over the course of the study. The HCAHPS ratings aligned with the sound meter data showing that patients perceived the noise levels to be lower with carpet tiles, improving patient satisfaction ratings. Perceptions for healthcare staff and patients were aligned with the sound meter data. Carpet tile provides sound absorption that affects sound levels and influences occupant's perceptions of environmental factors that contribute to the quality of the indoor environment. Flooring that provides comfort underfoot, easy cleanability, and sound absorption influence healthcare worker job satisfaction and patient satisfaction with their patient experience. © The Author(s) 2015.

  13. Recognition and Management of Nonrelaxing Pelvic Floor Dysfunction

    Science.gov (United States)

    Faubion, Stephanie S.; Shuster, Lynne T.; Bharucha, Adil E.

    2012-01-01

    Nonrelaxing pelvic floor dysfunction is not widely recognized. Unlike in pelvic floor disorders caused by relaxed muscles (eg, pelvic organ prolapse or urinary incontinence, both of which often are identified readily), women affected by nonrelaxing pelvic floor dysfunction may present with a broad range of nonspecific symptoms. These may include pain and problems with defecation, urination, and sexual function, which require relaxation and coordination of pelvic floor muscles and urinary and anal sphincters. These symptoms may adversely affect quality of life. Focus on the global symptom complex, rather than the individual symptoms, may help the clinician identify the condition. The primary care provider is in a position to intervene early, efficiently, and effectively by (1) recognizing the range of symptoms that might suggest nonrelaxing pelvic floor dysfunction, (2) educating patients, (3) performing selective tests when needed to confirm the diagnosis, and (4) providing early referral for physical therapy. PMID:22305030

  14. Glazed Tiles as Floor Finish in Nigeria

    Directory of Open Access Journals (Sweden)

    Toyin Emmanuel AKINDE

    2013-09-01

    Full Text Available Tile is no doubt rich in antiquity; its primordial  show, came as mosaic with primary prospect in sacred floor finish before its oblivion, courtesy of, later consciousness towards wall finish in banquets, kitchens, toilets, restaurants and even bars. Today, its renaissance as floor finish is apparent in private and public architectural structures with prevalence in residential, recreational, commercial, governmental and other spaces. In Nigeria, the use of glazed tiles as floor finish became apparent, supposedly in mid-twentieth century; and has since, witnessed ever increasing demands from all sundry; a development that is nascent and has necessitated its mass  production locally with pockets of firms in the country. The latter however, is a resultant response to taste cum glazed tiles affordability, whose divergent sophistication in design, colour, size and shape is believed preferred to terrazzo, carpet and floor flex tile. Accessible as glazed tile and production is, in recent times; its dearth of a holistic literature in Nigeria is obvious. In the light of the latter, this paper examine glazed tiles as floor finish in Nigeria, its advent, usage, production, challenge, benefit and prospect with the hope of opening further frontier in discipline specifics.

  15. Barriers to Pelvic Floor Physical Therapy Regarding Treatment of High-Tone Pelvic Floor Dysfunction.

    Science.gov (United States)

    Zoorob, Dani; Higgins, Margaret; Swan, Kimberly; Cummings, Jennifer; Dominguez, Sarah; Carey, Erin

    Chronic pelvic pain is a prevalent and debilitating condition with a wide range of etiologies. An estimated 30% to 70% of chronic pelvic cases involve musculoskeletal component pain including high-tone pelvic floor dysfunction (HTPFD). Pelvic floor physical therapy has been shown to be a beneficial treatment for HTPFD, yet many patients do not have access to this treatment. The objective of this study was to identify the barriers preventing patients from following through with the first-line management, physical therapy. Participants with a diagnosis of HTPFD (n = 154) were identified from the list of referrals sent from the obstetrics and gynecology department to an affiliated PFPT center. Participants were contacted and asked to complete a phone survey addressing demographics and perceived barriers to care. Responses were collected in REDCap. Univariate and bivariate analyses were performed using a statistical analysis software. Seventy surveys were completed. The top barriers identified by participants were financial constraints (51.4%), perceived lack of utility (37.1%), time constraints (30.0%), and travel issues (18.6%); 84.4% of participants had 1 or more comorbid pain condition. Whereas 51.4% expressed some level of anxiety regarding the PFPT option, only 9.6% of participants did not start treatment because of fear of treatment. The majority of treatment barriers identified were concrete restraints, with insurance noncoverage and time constraints being the top issues. A fair number of participants expressed anxiety about the treatment or felt they received unclear explanations of the treatment. These are areas in which providers can potentially alleviate some barriers to care.

  16. Uranium, thorium, gross alpha and gross beta assessment in fountain waters in towns of the Iron Quadrangle, Brazil

    International Nuclear Information System (INIS)

    Ferreira, Claudia A.; Palmieri, Helena E.L.; Menezes, Maria Angela de B.C.; Chaves, Renata D.A.; Dalmazio, Ilza

    2013-01-01

    The Iron Quadrangle region is known worldwide for its diversity, both ores and rock types, which record a long and important period of Earth's history. For thousands of years erosive processes have exposed ancient rocks, Archean and Proterozoic, in this region. The concentration of uranium, thorium, gross alpha and gross beta activities has been assessed in 34 fountains water samples collected from different towns in the Iron Quadrangle. The results obtained were compared to values established by CONAMA nº 396/2008 and Decree nº 2914/2011 by the Ministry of Health. For Th in water consumption there is no value established in the Brazilian legislation and the concentrations in all samples were lower than 0.01 μg L -1 . For uranium, the values ranged from less than 0.002 to 0.61 μg L -1 , and all results were lower than the value allowed of 15 μg L -1 and 30 μg L -1 established by the legislations above, respectively. The results for the radiation levels of gross alpha and gross beta activity in some fountains waters were slightly above the limits (0.5 Bq L -1 and 1.0 Bq L -1 ) established by CONAMA nº 396/2008 and Decreet nº 2914/2011, respectively. (author)

  17. What Is Low Profile Access Flooring and Why More Businesses Need It

    OpenAIRE

    NetfloorUSA

    2017-01-01

    Low profile access flooring is being commonly used in a variety of businesses today. To understand why more businesses, need this type of flooring, it is essential that we take the time to first understand what is low profile flooring actually is. What Is Low Profile Access Flooring A low profile access floor is a floor that is designed to sit above the original concrete slab flooring installed in any home, business, or public building. The higher floor height creates a space between ...

  18. Polygons on Crater Floor

    Science.gov (United States)

    2003-01-01

    MGS MOC Release No. MOC2-357, 11 May 2003This Mars Global Surveyor (MGS) Mars Orbiter Camera (MOC) picture shows a pattern of polygons on the floor of a northern plains impact crater. These landforms are common on crater floors at high latitudes on Mars. Similar polygons occur in the arctic and antarctic regions of Earth, where they indicate the presence and freeze-thaw cycling of ground ice. Whether the polygons on Mars also indicate water ice in the ground is uncertain. The image is located in a crater at 64.8oN, 292.7oW. Sunlight illuminates the scene from the lower left.

  19. Determination of radon daughter activities of different aerosol fractions by gross-α and gross-β measurements

    International Nuclear Information System (INIS)

    Katona, T.; Kanyar, B.; Jobbagy, V.; Kavasi, N.; Molnar, A.; Imre, K.

    2004-01-01

    The aim was to determine the radioactivities of the radon progenies ( 218 Po, 214 Pb, 214 Bi and 214 Po) attached to the carrier aerosol particles with respect to the size distribution in order to improve the assessment of the inhalation dose. We derived the radionuclide-specific activity concentrations from gross alpha and gross beta measurements provided during 2 hours after sampling and model calculations including parameter estimation. For the aerosol sampling we used an electrical low pressure impactor, which is able to collect aerosol particles in 12 different diameter ranges. In our test investigations the aerosol particles were collected from a closed chamber in a common laboratory building. The chamber contained a relatively high radon concentration (60-90 kBq/m 3 ) in equilibrium with the short lived daughters generated previously without any additional aerosol sources. For the nuclear measurements of the aerosol samples ZnS/plastic sandwich detectors have been used. The time series data of gross alpha and gross beta activities were fitted simultaneously and the initial activities of the daughters were estimated. According to the results from two different fractions (0.06 and 0.7 μm) just followed the end of sampling they contain a higher 218 Po activity than the 214 Pb and 214 Bi ones. The preliminary assessments for the special air conditions show that the 214 Pb-to- 218 Po activity ratios are higher for the small aerosol particles than for the larger ones. The estimated errors of the initial activities were near to 50% in a large part of cases. (author)

  20. 17 CFR 240.11a-1 - Regulation of floor trading.

    Science.gov (United States)

    2010-04-01

    ... 17 Commodity and Securities Exchanges 3 2010-04-01 2010-04-01 false Regulation of floor trading... Securities Exchange Act of 1934 Adoption of Floor Trading Regulation (rule 11a-1) § 240.11a-1 Regulation of floor trading. (a) No member of a national securities exchange, while on the floor of such exchange...

  1. Physical distribution of oak strip flooring 1969

    Science.gov (United States)

    William C. Miller; William C. Miller

    1971-01-01

    As an aid to the marketing of oak strip flooring, a study was made of the distribution process for this product, from manufacture to consumer-where the flooring came from, where it went, how much was shipped, and who handled it.

  2. Pelvic floor muscle training as a persistent nursing intervention: Effect on delivery outcome and pelvic floor myodynamia

    Directory of Open Access Journals (Sweden)

    Xin Wang

    2014-03-01

    Conclusion: Persistent nursing intervention for pregnant/postpartum women helped to shorten the second stage of labour and contributed to the recovery of postpartum pelvic floor myodynamia. The influence of this intervention on the delivery mode, and rates of episiotomy and perineal laceration remains unknown. Medical staff should strengthen health education programmes that involve pelvic floor functional rehabilitation.

  3. Assessment of the effect of pelvic floor exercises on pelvic floor muscle strength using ultrasonography in patients with urinary incontinence: a prospective randomized controlled trial

    OpenAIRE

    Tosun, Ozge Celiker; Solmaz, Ulas; Ekin, Atalay; Tosun, Gokhan; Gezer, Cenk; Ergenoglu, Ahmet Mete; Yeniel, Ahmet Ozgur; Mat, Emre; Malkoc, Mehtap; Askar, Niyazi

    2016-01-01

    [Purpose] The aim of this study was to evaluate whether the effect of pelvic floor exercises on pelvic floor muscle strength could be detected via ultrasonography in patients with urinary incontinence. [Subjects and Methods] Of 282 incontinent patients, 116 participated in the study and were randomly divided into a pelvic floor muscle training (n=65) group or control group (n=51). The pelvic floor muscle training group was given pelvic floor exercise training for 12 weeks. Both groups were ev...

  4. Influence of Soft or Hard Floors before and after First Calving on Dairy Heifer Locomotion, Claw and Leg Health

    Directory of Open Access Journals (Sweden)

    Christer Bergsten

    2015-08-01

    Full Text Available Claw health, an important dairy cow welfare parameter, may be affected by early-life foot/leg stresses. To investigate this, groups of pregnant heifers were allocated to deep straw bedding (Soft or cubicles (Hard, both with scraped concrete feeding alleys. After the grazing season, they were re-housed in cubicle systems, half on slatted concrete (Hard and half on slatted rubber (Soft alleys. Claw measurements, contact area and pressure distribution claw/flooring, claw disorders and leg lesions were recorded at the start and end of each housing season. Locomotion and leg lesions were also scored monthly after calving. Prevalence of sole haemorrhages was higher among pregnant heifers in cubicles than in deep straw. After calving, first-calvers on Hard floors had higher odds for lameness (OR = 3.6; P < 0.01, sole haemorrhages/ulcers (OR = 2.2; P < 0.05, white-line haemorrhages (OR = 2.8; P < 0.01 and leg lesions (OR = 2.6; P < 0.02 than those on Soft floors. Lowest prevalence and severity of sole and white-line haemorrhages (non-significant in first-calvers was found in those on Soft floors and reared on Hard floors and the highest prevalence and severity on those on Hard floors reared on Soft floors. Soft flooring after calving is of most importance for healthy feet and legs.

  5. Air gun near the sea floor as shear-wave source?

    NARCIS (Netherlands)

    Drijkoningen, G.G.; Dieulangard, D.; Holicki, M.E.

    2015-01-01

    The feasibility of using an air gun near the sea floor as shear-wave source has been investigated. With an air gun near the sea floor, an evanescent P-wave in the water becomes a propagating S-wave in the sea floor, such that it seems that a pure shear-wave source has been used at the sea floor.

  6. Dermoid cyst in the mouth floor

    International Nuclear Information System (INIS)

    Portelles Masso, Ayelen Maria; Torres Inniguez, Ailin Tamara.

    2010-01-01

    The Dermoid cyst account for the 0.01 % of all cysts of buccal cavity. Its more frequent location is in the mouth floor. This is the case of a female patient aged 19 who approximately 7 years noted an increase of volume under tongue growing gradually and noting outside face and the discomfort at to speak and to chew. Complementary studies were conducted and under general anesthesia a surgical exeresis was carried out by intrabuccal approach achieving excellent esthetic and functional results. Histopathologic diagnosis matched with a dermoid cyst of mouth floor. Patient has not lesion recurrence after three years after operation. We conclude that the Dermoid cyst of mouth floor appear as benign tumor of middle line. The intrabuccal exeresis demonstrates esthetic and functional benefits. (author)

  7. Gross Domestic Savings and Gross Capital: what Matters to Their Formation in an Era of Economic Recession in Nigeria?

    Directory of Open Access Journals (Sweden)

    Success Abusomwan

    2017-09-01

    Full Text Available The objective of this study is to empirically investigate the long run and short run dynamic impact of interest rate and output on gross domestic savings and gross capital formation in Nigeria. Literatures, both theoretical and empirical, suggest that the rate of interest and output are the key factors influencing savings and investments. A review of factors influencing interest rates and output in Nigeria is necessitated by the recent economic downturns in Nigeria that has resulted in tight monetary policy which some commentators regard as inimical to growth. Employing Ordinary Least Squares, Co-integration, Error Correction Mechanism and Granger Causality econometric techniques on a data spanning 1981 to 2014 of the Nigerian economy sourced from the World Development Index, it was found that changes in output explains the long run and short run dynamic behaviour of gross domestic savings and gross capital formation which were used as proxies for savings and investment respectively. Whereas, a bi-causality was established between output and investment, causality flowed from output to savings in Nigeria. The research also found that interest rate is not a significant determinant of savings and investment in Nigeria in both long run and short run. It is therefore recommended that to enhance investment in a period of economic downturn in Nigeria, aggregate demand should be boosted to enhance output through vigorous pursuit of fiscal policy while implementing contractionary monetary policy to address inflationary pressures created by the increase in demand. Domestic savings will improve and gross capital formation will be sustained.

  8. Estimation of inhalation doses from airborne releases using gross monitors

    International Nuclear Information System (INIS)

    Goldstein, N.P.

    1978-01-01

    Monitoring programs at most nuclear facilities involve continuous gross measurements supplemented by periodic isotopic analyses of release samples. The isotopic measurements are required to accurately assess the potential dose from the various effluent streams, but in between these measurements, one depends on the gross monitors to provide approximate indications of the dose. The effluent streams release a variety of nuclides, each with its own dose factor. This means that the relationship between the counting rate in a gross monitor and the potential dose of the effluent being monitored will depend on the isotopic composition of this release. If this composition changes, then the dose indicated by the gross monitor (calibrated for the original group of isotopes) may be significantly in error. The problem of indicating inhalation doses from gross monitoring of airborne releases is considered. In order for this type of monitor to accurately indicate dose, regardless of the isotopic makeup of a release, the analysis shows that its response to each isotope should be proportional to the dose factor of that isotope. These ideas are applied to the monitoring of air particulates using gross beta and gross gamma monitors. The study shows that the former more closely satisfies this condition and as a result, satisfactorily indicates the actual dose from reactor effluents, as determined from detailed isotopic data published in the literature. On the other hand, the gross gamma monitor, with its poorer fit to the condition, provided less than satisfactory accuracy in its dose estimates. In addition, a variety of other mathematical response functions were considered but their dose estimation capabilities were not much better than the straight beta response. The study shows that reasonably accurate dose estimates can be made using properly selected gross monitors, but that significant errors can result with improper ones. (author)

  9. Improving the cleaning procedure to make kitchen floors less slippery.

    Science.gov (United States)

    Quirion, F; Poirier, P; Lehane, P

    2008-12-01

    This investigation shows that, in most cases, the floor cleaning procedure of typical restaurants could be improved, resulting in a better cleaning efficiency and a better floor friction. This simple approach could help reduce slips and falls in the workplace. Food safety officers visited ten European style restaurants in the London Borough of Bromley (UK) to identify their floor cleaning procedure in terms of the cleaning method, the concentration and type of floor cleaner and the temperature of the wash water. For all 10 restaurants visited, the cleaning method was damp mopping. Degreasers were used in three sites while neutral floor cleaners were used in seven sites. Typically, the degreasers were over diluted and the neutrals were overdosed. The wash water temperature ranged from 10 to 72 degrees C. The on-site cleaning procedures were repeated in the laboratory for the removal of olive oil from new and sealed quarry tiles, fouled and worn quarry tiles and new porcelain tiles. It is found that in 24 out of 30 cases, cleaning efficiency can be improved by simple changes in the floor cleaning procedure and that these changes result in a significant improvement of the floor friction. The nature of the improved floor cleaning procedure depends on the flooring type. New and properly sealed flooring tiles can be cleaned using damp mopping with a degreaser diluted as recommended by the manufacturer in warm or hot water (24 to 50 degrees C). But as the tiles become worn and fouled, a more aggressive floor cleaning is required such as two-step mopping with a degreaser diluted as recommended by the manufacturer in warm water (24 degrees C).

  10. Nondestructive structural evaluation of wood floor systems with a vibration technique.

    Science.gov (United States)

    Xiping Wang; Robert J. Ross; Lawrence Andrew Soltis

    2002-01-01

    The objective of this study was to determine if transverse vibration methods could be used to effectively assess the structural integrity of wood floors as component systems. A total of 10 wood floor systems, including 3 laboratory-built floor sections and 7 in-place floors in historic buildings, were tested. A forced vibration method was applied to the floor systems...

  11. Improvement of PVC floor tiles by gamma radiation

    International Nuclear Information System (INIS)

    Plessis, T.A. du; Badenhorst, F.

    1988-01-01

    Gamma radiation presents a unique method of transforming highly plasticized PVC floor tiles, manufactured at high speed through injection moulding, into a high quality floor covering at a cost at least 30% less than similarly rated rubber tiles. A specially formulated PVC compound was developed in collaboration with a leading manufacturer of floor tiles. These tiles are gamma crosslinked in its shipping cartons to form a dimensionally stable product which is highly fire resistant and inert to most chemicals and solvents. These crosslinked tiles are more flexible than the highly filled conventional PVC floor tiles, scratch resistant and have a longer lifespan and increased colour fastness. These tiles are also less expensive to install than conventional rubber tiles. (author)

  12. Psychiatric Symptoms in Children with Gross Motor Problems

    Science.gov (United States)

    Emck, Claudia; Bosscher, Ruud J.; van Wieringen, Piet C. W.; Doreleijers, Theo; Beek, Peter J.

    2012-01-01

    Children with psychiatric disorders often demonstrate gross motor problems. This study investigates if the reverse also holds true by assessing psychiatric symptoms present in children with gross motor problems. Emotional, behavioral, and autism spectrum disorders (ASD), as well as psychosocial problems, were assessed in a sample of 40 children…

  13. The pelvic floor muscles: muscle thickness in healthy and urinary-incontinent women measured by perineal ultrasonography with reference to the effect of pelvic floor training. Estrogen receptor studies

    DEFF Research Database (Denmark)

    Bernstein, Inge Thomsen

    1997-01-01

    demonstrated that the striated periurethral muscles and the pelvic floor muscles are of paramount importance for the closure function. This emphasizes the importance of well-functioning pelvic floor muscles to obtain continence, and probably explains the rationale for the effect of pelvic floor training...... in treating urinary incontinence. This study presents a review of the literature on female urinary incontinence, continence mechanisms, pelvic floor muscles, and pelvic floor training. Furthermore, a review of the literature on estrogen receptors in the pelvic floor muscles is given. Perineal ultrasonography...... the effect of pelvic floor training. Additionally, a study of the Pelvic floor muscles was performed to assess the presence of estrogen receptors. Muscle thickness seems to decrease with age. In women over age 60 years, a significantly thinner pelvic floor muscle was found compared to younger women...

  14. Piezoelectric energy harvester under parquet floor

    Science.gov (United States)

    Bischur, E.; Schwesinger, N.

    2011-03-01

    The design, fabrication and testing of piezoelectric energy harvesting modules for floors is described. These modules are used beneath a parquet floor to harvest the energy of people walking over it. The harvesting modules consist of monoaxial stretched PVDF-foils. Multilayer modules are built up as roller-type capacitors. The fabrication process of the harvesting modules is simple and very suitable for mass production. Due to the use of organic polymers, the modules are characterized by a great flexibility and the possibility to create them in almost any geometrical size. The energy yield was determined depending on the dynamic loading force, the thickness of piezoelectric active material, the size of the piezoelectric modules, their alignment in the walking direction and their position on the floor. An increase of the energy yield at higher loading forces and higher thicknesses of the modules was observed. It was possible to generate up to 2.1mWs of electric energy with dynamic loads of 70kg using a specific module design. Furthermore a test floor was assembled to determine the influence of the size, alignment and position of the modules on the energy yield.

  15. The Gross Motor Skills of Children with Mild Learning Disabilities

    Science.gov (United States)

    Nonis, Karen P.; Jernice, Tan Sing Yee

    2014-01-01

    Many international studies have examined the gross motor skills of children studying in special schools while local studies of such nature are limited. This study investigated the gross motor skills of children with Mild Learning Disabilities (MLD; n = 14, M age = 8.93 years, SD = 0.33) with the Test of Gross Motor Development-2 (TGMD-2, Ulrich,…

  16. A NEW PORTABLE INSTRUMENT TO EVALUATE SOFT FLOORING MATERIALS IN DAIRY COW HOUSING

    Directory of Open Access Journals (Sweden)

    Paolo Liberati

    2012-06-01

    Full Text Available The improvement of flooring materials performance on animal health and welfare requires the support of reliable testing techniques. This is particularly relevant with the synthetic soft coverings used for walking areas since the friction coefficient is not only dependent on the surface characteristics, but also on the penetration of the animal hoof into the material. The paper presents the functioning of a new instrument capable of reproducing more closely the real interaction between the floor surface and the animal foot. The instrument is simple and portable and is suitable both for laboratory measurements and real housing conditions. The measurement is made in two steps: first a probe, shaped as a cow hoof and contacting the testing floor surface, is loaded with a vertical force to obtain a pressure similar to that exerted by the animal; then a pushing force parallel to the floor is applied, at a constant speed, producing a displacement along the surface. The values of the vertical and horizontal strengths required for skidding and the angle of the instrument are continuously measured and by them various parameters can be calculated. The results of the tests carried out in the laboratory and in real dairy houses are presented and, through the analysis of various calculated physical parameters, the main floor properties – more suitable for a previous estimate of the effect on animal welfare – are determined and discussed. In particular, the IPF parameter has been the only one able to predict also the foot escape among all the considered parameters.

  17. 75 FR 70061 - Dealer Floor Plan Pilot Program Meeting

    Science.gov (United States)

    2010-11-16

    ... SMALL BUSINESS ADMINISTRATION Dealer Floor Plan Pilot Program Meeting AGENCY: U.S. Small Business... location, date, time, and agenda for a meeting regarding the Dealer Floor Plan Pilot Program established in the Small Business Jobs Act of 2010. The meeting will be open to the public. DATES: The Dealer Floor...

  18. Ploughing the deep sea floor.

    Science.gov (United States)

    Puig, Pere; Canals, Miquel; Company, Joan B; Martín, Jacobo; Amblas, David; Lastras, Galderic; Palanques, Albert

    2012-09-13

    Bottom trawling is a non-selective commercial fishing technique whereby heavy nets and gear are pulled along the sea floor. The direct impact of this technique on fish populations and benthic communities has received much attention, but trawling can also modify the physical properties of seafloor sediments, water–sediment chemical exchanges and sediment fluxes. Most of the studies addressing the physical disturbances of trawl gear on the seabed have been undertaken in coastal and shelf environments, however, where the capacity of trawling to modify the seafloor morphology coexists with high-energy natural processes driving sediment erosion, transport and deposition. Here we show that on upper continental slopes, the reworking of the deep sea floor by trawling gradually modifies the shape of the submarine landscape over large spatial scales. We found that trawling-induced sediment displacement and removal from fishing grounds causes the morphology of the deep sea floor to become smoother over time, reducing its original complexity as shown by high-resolution seafloor relief maps. Our results suggest that in recent decades, following the industrialization of fishing fleets, bottom trawling has become an important driver of deep seascape evolution. Given the global dimension of this type of fishery, we anticipate that the morphology of the upper continental slope in many parts of the world’s oceans could be altered by intensive bottom trawling, producing comparable effects on the deep sea floor to those generated by agricultural ploughing on land.

  19. Uranium, thorium, gross alpha and gross beta assessment in fountain waters in towns of the Iron Quadrangle, Brazil

    Energy Technology Data Exchange (ETDEWEB)

    Ferreira, Claudia A.; Palmieri, Helena E.L.; Menezes, Maria Angela de B.C.; Chaves, Renata D.A.; Dalmazio, Ilza, E-mail: cferreiraquimica@yahoo.com.br, E-mail: help@cdtn.br, E-mail: menezes@cdtn.br, E-mail: rda@cdtn.br, E-mail: id@cdtn.br [Centro de Desenvolvimento da Tecnologia Nuclear (CDTN/CNEN-MG), Belo Horizonte, MG (Brazil)

    2013-07-01

    The Iron Quadrangle region is known worldwide for its diversity, both ores and rock types, which record a long and important period of Earth's history. For thousands of years erosive processes have exposed ancient rocks, Archean and Proterozoic, in this region. The concentration of uranium, thorium, gross alpha and gross beta activities has been assessed in 34 fountains water samples collected from different towns in the Iron Quadrangle. The results obtained were compared to values established by CONAMA nº 396/2008 and Decree nº 2914/2011 by the Ministry of Health. For Th in water consumption there is no value established in the Brazilian legislation and the concentrations in all samples were lower than 0.01 μg L{sup -1}. For uranium, the values ranged from less than 0.002 to 0.61 μg L{sup -1}, and all results were lower than the value allowed of 15 μg L{sup -1} and 30 μg L{sup -1} established by the legislations above, respectively. The results for the radiation levels of gross alpha and gross beta activity in some fountains waters were slightly above the limits (0.5 Bq L{sup -1} and 1.0 Bq L{sup -1}) established by CONAMA nº 396/2008 and Decreet nº 2914/2011, respectively. (author)

  20. Industrial tests of rock consolidation for fighting floor swelling

    Energy Technology Data Exchange (ETDEWEB)

    Pirskii, A A; Stovpnik, S N [KPI (USSR)

    1990-04-01

    Reports on investigations into the mechanism of floor swelling in main roadways and into rock mass stabilization by consolidating fluid injection combined with blasting. The principal cause of deterioration in the stability of workings is considered to be the state of stress in the rock mass, rock destruction in side walls where rock blocks are being pressed into the floor while the floor rock is squeezed out into the working space. A case study of fluid injection combined with blasting applied in several mines in the Donbass is presented where holes were drilled 1.5-3 m deep and explosive charges of 0.07-0.1 kg/hole and injection of hardening solutions (0.56-0.83 m{sup 3}/m of workings) were applied. As a result floor swelling rates were reduced by up to about 5 times (e.g. from 2.5 mm/d to 0.5 mm/d.). The period of maintenence free upkeep of workings was extended to 6-8 years. The economic effect in maintenance of 1 m of workings was 11.7 rubles for floor consolidation without sidewall bolting and 51.4 rubles for floor consolidation combined with sidewall bolting. Recommendations that concern the technology of floor consolidation by fluid injection and blasting are made. 4 refs.

  1. The relationship between gross motor skills and visual perception of preschoolers

    OpenAIRE

    TEPELI, Kezban

    2014-01-01

    Answers were searched for these questions; “Is there a relationship between visual perceptions and gross motor skills of preschool children?”, “Are preschool children's visual perceptions predictors of their gross motor skills?”, “Is there any difference between visual perceptions of the children having low, average and high level of gross motor skills?” within this study where the relationship between preschool children's visual perceptions and their gross motor skills were compara...

  2. Experimental Investigation of Properties of Foam Concrete for Industrial Floors in Testing Field

    Science.gov (United States)

    Vlcek, Jozef; Drusa, Marian; Scherfel, Walter; Sedlar, Bronislav

    2017-12-01

    Foam concrete (FC), as a mixture of cement, water, additives and technical foam, is well known for more than 30 years. It is building material with good mechanical properties, low thermal conductivity, simple and even high technological treatment. Foam concrete contains closed void pores, what allows achieving low bulk density and spare of raw materials. Thanks to its properties, it is usable as a replacement of conventional subbase layers of the industrial floors, the transport areas or as a part of the foundation structures of the buildings. Paper presents the preparation of the testing field (physical model) which was created for experimental investigation of the foam concrete subbase layer of the industrial floor in a real scale.

  3. Gross morphology of rhea oropharyngeal cavity

    Directory of Open Access Journals (Sweden)

    Marcio N. Rodrigues

    2012-12-01

    Full Text Available The rhea (Rhea americana americana is an american bird belonging to Ratite's family. Studies related to its morphology are still scarce. This study aims to describe the macroscopic structures of the oropharyngeal cavity. Five heads (2 to 6 months old formalin preserved were anatomically dissected to expose the oropharynx. The oropharynx of the rhea was "bell-shaped" composed by the maxillary and mandibular rhamphotheca. The roof and floor presented two distinct regions different in colour of the mucosa. The rostral region was pale pink contrasting to grey coloured caudal region. The median longitudinal ridge extended rostrally from the apex of the choana to the tip of the beak in the roof and it is clearly more prominent and rigid than the homolog in the floor that appeared thin and stretched merely along the rostral portion of the regio interramalis. The floor was formed by the interramal region, (regio interramalis tongue and laryngeal mound containing glove-shaped glottis. This study confirmed the basic morphology of the oropharinx of the rhea. However, important morphological information not previously described is highlighted and contradictory information present in the literature is clarified.

  4. The role of dirt floors and of firewood in rural dwellings in the epidemiology of Chagas' disease in Costa Rica.

    Science.gov (United States)

    Zeledón, R; Vargas, L G

    1984-03-01

    In an endemic area of Chagas' disease in Costa Rica, 50 houses infested with Triatoma dimidiata were re-examined after a period of 14-17 years. Criteria used were two socioeconomic parameters which are closely associated with the presence of the bugs: colonies of triatomines inside houses are favored by the presence of a dirt floor, and stored firewood is an excellent refuge for insects outdoors. Indoor infestation was completely eliminated from nine of 13 houses in which the floors had been changed from dirt to concrete during this period, and nearly eliminated from the other four, supporting the hypothesis that the disappearance of dirt floors makes it difficult for the bugs to thrive inside houses. Of the 21 houses that lost the infestation (inside, outside, or both), firewood had been eliminated in 13, and of 29 houses that remained infested firewood had been eliminated in only two. An inverse relationship was found between distance of firewood piles from the house and presence of bugs. It is supposed that a colony of insects frequently starts in stored firewood and then moves into the household if a dirt floor is present. Removal of firewood and replacement of dirt floors by concrete would provide good prophylactic measures against the transmission of Chagas' disease in areas where T. dimidiata is the vector.

  5. Modern Theories of Pelvic Floor Support : A Topical Review of Modern Studies on Structural and Functional Pelvic Floor Support from Medical Imaging, Computational Modeling, and Electromyographic Perspectives.

    Science.gov (United States)

    Peng, Yun; Miller, Brandi D; Boone, Timothy B; Zhang, Yingchun

    2018-02-12

    Weakened pelvic floor support is believed to be the main cause of various pelvic floor disorders. Modern theories of pelvic floor support stress on the structural and functional integrity of multiple structures and their interplay to maintain normal pelvic floor functions. Connective tissues provide passive pelvic floor support while pelvic floor muscles provide active support through voluntary contraction. Advanced modern medical technologies allow us to comprehensively and thoroughly evaluate the interaction of supporting structures and assess both active and passive support functions. The pathophysiology of various pelvic floor disorders associated with pelvic floor weakness is now under scrutiny from the combination of (1) morphological, (2) dynamic (through computational modeling), and (3) neurophysiological perspectives. This topical review aims to update newly emerged studies assessing pelvic floor support function among these three categories. A literature search was performed with emphasis on (1) medical imaging studies that assess pelvic floor muscle architecture, (2) subject-specific computational modeling studies that address new topics such as modeling muscle contractions, and (3) pelvic floor neurophysiology studies that report novel devices or findings such as high-density surface electromyography techniques. We found that recent computational modeling studies are featured with more realistic soft tissue constitutive models (e.g., active muscle contraction) as well as an increasing interest in simulating surgical interventions (e.g., artificial sphincter). Diffusion tensor imaging provides a useful non-invasive tool to characterize pelvic floor muscles at the microstructural level, which can be potentially used to improve the accuracy of the simulation of muscle contraction. Studies using high-density surface electromyography anal and vaginal probes on large patient cohorts have been recently reported. Influences of vaginal delivery on the

  6. Management of disorders of the posterior pelvic floor.

    Science.gov (United States)

    Berman, Loren; Aversa, John; Abir, Farshad; Longo, Walter E.

    2005-01-01

    INTRODUCTION: Constipation is a relatively common problem affecting 15 percent of adults in the Western world, and over half of these cases are related to pelvic floor disorders. This article reviews the clinical presentation and diagnostic approach to posterior pelvic floor disorders, including how to image and treat them. METHODS: A Pubmed search using keywords "rectal prolapse," "rectocele," "perineal hernia," and "anismus" was performed, and bibliographies of the revealed articles were cross-referenced to obtain a representative cross-section of the literature, both investigational studies and reviews, that are currently available on posterior pelvic floor disorders. DISCUSSION: Pelvic floor disorders can occur with or without concomitant physical anatomical defects, and there are a number of imaging modalities available to detect such abnormalities in order to decide on the appropriate course of treatment. Depending on the nature of the disorder, operative or non-operative therapy may be indicated. CONCLUSION: Correctly diagnosing pelvic floor disorders can be complex and challenging, and the various imaging modalities as well as clinical history and exam must be considered together in order to arrive at a diagnosis. PMID:16720016

  7. Dispersion of UO2F2 aerosol and HF vapor in the operating floor during winter ventilation at the Paducah Gaseous Diffusion Plant

    International Nuclear Information System (INIS)

    Kim, S.H.; Chen, N.C.J.; Taleyarkhan, R.P.; Keith, K.D.; Schmidt, R.W.; Carter, J.C.

    1996-01-01

    The gaseous diffusion process is currently employed at two plants in the US: the Paducah Gaseous Diffusion Plant and the Portsmouth Gaseous Diffusion Plant. As part of a facility-wide safety evaluation, a postulated design basis accident involving large line-rupture induced releases of uranium hexafluoride (UF 6 ) into the process building of a gaseous diffusion plant (GDP) is evaluated. When UF 6 is released into the atmosphere, it undergoes an exothermic chemical reaction with moisture (H 2 O) in the air to form vaporized hydrogen fluoride (HF) and aerosolized uranyl fluoride (UO 2 F 2 ). These reactants disperse in the process building and transport through the building ventilation system. The ventilation system draws outside air into the process building, distributes it evenly throughout the building, and discharges it to the atmosphere at an elevated temperature. Since air is recirculated from the cell floor area to the operating floor, issues concerning in-building worker safety and evacuation need to be addressed. Therefore, the objective of this study is to evaluate the transport of HF vapor and UO 2 F 2 aerosols throughout the operating floor area following B-line break accident in the cell floor area

  8. Special aspects of attic floor warming in historic buildings

    Directory of Open Access Journals (Sweden)

    Murgul Vera

    2017-01-01

    Full Text Available This article containsreasoningof the heat transfer performance uniformity factor determination for attic floors of historic residential buildings while energy effective modifying buildings. The numeral value of this heat transfer performance uniformity factor for the wooden attic floor structure was founddurung investigation. It was estimated that there was no moisture condensation in the wooden attic floor structure.

  9. Short communication: Flooring preferences of dairy cows at calving.

    Science.gov (United States)

    Campler, M; Munksgaard, L; Jensen, M B; Weary, D M; von Keyserlingk, M A G

    2014-02-01

    The present study investigated the flooring preference during the 30 h before parturition in Holstein dairy cows housed individually in a maternity pen. Seventeen multiparous cows were moved, on average, 2 d before expected calving date into an individual maternity pen with 3 different flooring surfaces: 10 cm of sand, pebble-top rubber mats, or concrete flooring, each covered with 15 cm of straw. Calving location, lying time, and total time and number of lying bouts on each of the floor types were recorded during 2 periods: precalving (24 to 29 h before calving) and at calving (0 to 5h before calving). Ten cows calved on sand, 6 on concrete, and 1 on the rubber mat. Lying bouts increased during the hours closest to calving, regardless of flooring. The number of lying bouts did not differ between flooring types precalving but cows had more lying bouts on sand and concrete compared with rubber at calving. Cows spent more time lying down on sand and concrete compared with rubber precalving, but lying times did not differ between treatments at calving. Cows that calved on sand spent more time lying on sand at calving compared with the other 2 flooring types. Cows that calved on concrete did not show a flooring preference at calving. These results indicate that rubber mats are the least preferred by dairy cows in the maternity pens, even when covered with a deep layer of straw. Copyright © 2014 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.

  10. Obtaining and Estimating Low Noise Floors in Vibration Sensors

    DEFF Research Database (Denmark)

    Brincker, Rune; Larsen, Jesper Abildgaard

    2007-01-01

    For some applications like seismic applications and measuring ambient vibrations in structures, it is essential that the noise floors of the sensors and other system components are low and known to the user. Some of the most important noise sources are reviewed and it is discussed how the sensor...... can be designed in order to obtain a low noise floor. Techniques to estimate the noise floors for sensors are reviewed and are demonstrated on a commercial commonly used sensor for vibration testing. It is illustrated how the noise floor can be calculated using the coherence between simultaneous...

  11. CAISSON TYPE HOLLOW FLOOR SLABS OF MONOLITHIC MULTI-STOREYED BUILDINGS

    Directory of Open Access Journals (Sweden)

    Malakhova Anna Nikolaevna

    2016-06-01

    Full Text Available One of the disadvantages of building structures made of reinforced concrete is their considerable weight. One of the trends to decrease the weight of concrete structures, including floor slabs, is the arrangement of voids in the cross-sectional building structures. In Russian and foreign practice paper, cardboard and plastic tubes has been used for creation of voids in the construction of monolithic floor slabs. Lightweight concretes were also used for production of precast hollow core floor slabs. The article provides constructive solutions of precast hollow core floor slabs and solid monolithic slabs that were used in the construction of buildings before wide use of large precast hollow core floor slabs. The article considers the application of caisson hollow core floor slabs for modern monolithic multi-storeyed buildings. The design solutions of such floor slabs, experimental investigations and computer modeling of their operation under load were described in this article. The comparative analysis of the calculation results of computer models of a hollow slabs formed of rod or plastic elements showed the similarity of calculation results.

  12. Soil Water Retention and Gross Primary Productivity in the Zábrod area in the Šumava Mts

    Czech Academy of Sciences Publication Activity Database

    Šír, Miloslav; Lichner, Ľ.; Tesař, Miroslav; Krejča, M.; Váchal, J.

    roč. 3, s. 1 (2008), s130-s138 ISSN 1801-5395 R&D Projects: GA AV ČR 1QS200420562; GA ČR GA205/05/2312; GA ČR GA205/06/0375; GA MŽP(CZ) SP/1A6/151/07 Institutional research plan: CEZ:AV0Z20600510 Keywords : hydrologic cycle * evapotranspiration * gross primary productivity * entropy production * soil water retention Subject RIV: DA - Hydrology ; Limnology

  13. [The physical therapy undergraduate students' responses to the gross human anatomy subjects].

    Science.gov (United States)

    Anahara, Reiko; Kawashiro, Yukiko; Matsuno, Yoshiharu; Mori, Chisato; Kohno, Toshihiko

    2008-09-01

    Instruction in gross human anatomy is one of the important items in the subject for co-medical students of the physical therapist course. The physical therapy undergraduate students are required to have a solid understanding of the structure and formation of the human body. Therefore, their good-understanding of the course on the gross human anatomy and their experience of the gross human anatomy laboratory (observation practice) are acquired to improve their knowledge of the human body. To clarify the student responses to the gross human anatomy course including the gross human anatomy laboratory, several questionnaires were administered to the freshman physical therapy undergraduate student for two years. We found that more than 80% of the students, who felt a negative attitude for gross human anatomy before the course started, had a positive attitude about the gross human anatomy after going through the course. The experience of the gross human anatomy laboratory increased the students' activity of learning and they thought more about the dignity of being human after the course than before viewing. In addition, the results suggested that the multiple experiences of the gross human anatomy course are useful for the physical therapy undergraduate students to improve the quality of their understanding of the human body.

  14. Pelvic floor dysfunction, and effects of pregnancy and mode of delivery on pelvic floor

    Directory of Open Access Journals (Sweden)

    Murat Bozkurt

    2014-12-01

    Full Text Available Pelvic floor dysfunction (PFD, although seems to be simple, is a complex process that develops secondary to multifactorial factors. The incidence of PFD is increasing with increasing life expectancy. PFD is a term that refers to a broad range of clinical scenarios, including lower urinary tract excretory and defecation disorders, such as urinary and anal incontinence, overactive bladder, and pelvic organ prolapse, as well as sexual disorders. It is a financial burden on the health care system and disrupts women's quality of life. Strategies applied to decrease PFD are focused on the course of pregnancy, mode and management of delivery, and pelvic exercise methods. Many studies in the literature define traumatic birth, usage of forceps, length of the second stage of delivery, and sphincter damage as modifiable risk factors for PFD. Maternal age, fetal position, and fetal head circumference are nonmodifiable risk factors. Although numerous studies show that vaginal delivery affects pelvic floor structures and their functions in a negative way, there is not enough scientific evidence to recommend elective cesarean delivery in order to prevent development of PFD. PFD is a heterogeneous pathological condition, and the effects of pregnancy, vaginal delivery, cesarean delivery, and possible risk factors of PFD may be different from each other. Observational studies have identified certain obstetrical exposures as risk factors for pelvic floor disorders. These factors often coexist; therefore, the isolated effects of these variables on the pelvic floor are difficult to study. The routine use of episiotomy for many years in order to prevent PFD is not recommended anymore; episiotomy should be used in selected cases, and the mediolateral procedures should be used if needed.

  15. Laparoscopic Pelvic Floor Repair Using Polypropylene Mesh

    Directory of Open Access Journals (Sweden)

    Shih-Shien Weng

    2008-09-01

    Conclusion: Laparoscopic pelvic floor repair using a single piece of polypropylene mesh combined with uterosacral ligament suspension appears to be a feasible procedure for the treatment of advanced vaginal vault prolapse and enterocele. Fewer mesh erosions and postoperative pain syndromes were seen in patients who had no previous pelvic floor reconstructive surgery.

  16. Pricing, renegotiation and gross inequities

    Energy Technology Data Exchange (ETDEWEB)

    Kirkham, J.S. (Van Cott, Bagley, Cornwall McCarthy, Salt Lake City, UT (USA))

    1990-01-01

    Reviews pricing, renegotiation and gross inequity provisions of coal supply agreements in order to provide practical assistance to an attorney called upon to draft in written form the intent of buyer and seller. 26 refs.

  17. Detection of lunar floor-fractured craters using machine learning methods

    Science.gov (United States)

    Thorey, C.

    2015-10-01

    About 200 Floor Fractured Craters (FFCs) have been identified by Schultz (1976) on the Moon, mainly around the lunar maria. These craters are a class of impact craters that are distinguished by having radi-ally and concentric floor-fractured networks and ab-normally shallow floors. In some cases, the uplift of the crater floor can be as large as 50% of the initial crater depth. These impact craters are interpreted to have undergone endogenous deformations after their formation.

  18. 29 CFR 1910.23 - Guarding floor and wall openings and holes.

    Science.gov (United States)

    2010-07-01

    ... 29 Labor 5 2010-07-01 2010-07-01 false Guarding floor and wall openings and holes. 1910.23 Section... floor and wall openings and holes. (a) Protection for floor openings. (1) Every stairway floor opening... opening and hole shall be guarded by a standard skylight screen or a fixed standard railing on all exposed...

  19. 26 CFR 1.872-1 - Gross income of nonresident alien individuals.

    Science.gov (United States)

    2010-04-01

    ... 26 Internal Revenue 9 2010-04-01 2010-04-01 false Gross income of nonresident alien individuals. 1...) INCOME TAX (CONTINUED) INCOME TAXES Nonresident Aliens and Foreign Corporations § 1.872-1 Gross income of nonresident alien individuals. (a) In general—(1) Inclusions. The gross income of a nonresident alien...

  20. Current usage and future trends in gross digital photography in Canada.

    Science.gov (United States)

    Horn, Christopher L; DeKoning, Lawrence; Klonowski, Paul; Naugler, Christopher

    2014-01-14

    The purpose of this study was to assess the current usage, utilization and future direction of digital photography of gross surgical specimens in pathology laboratories across Canada. An online survey consisting of 23 multiple choice and free-text questions regarding gross digital photography was sent out to via email to laboratory staff across Canada involved in gross dissection of surgical specimens. Sixty surveys were returned with representation from most of the provinces. Results showed that gross digital photography is utilized at most institutions (90.0%) and the primary users of the technology are Pathologists (88.0%), Pathologists' Assistants (54.0%) and Pathology residents (50.0%). Most respondents felt that there is a definite need for routine digital imaging of gross surgical specimens in their practice (80.0%). The top two applications for gross digital photography are for documentation of interesting/ complex cases (98.0%) and for teaching purposes (84.0%). The main limitations identified by the survey group are storage space (42.5%) and security issues (40.0%). Respondents indicated that future applications of gross digital photography mostly include teaching (96.6%), presentation at tumour boards/ clinical rounds (89.8%), medico-legal documentation (72.9%) and usage for consultation purposes (69.5%). The results of this survey indicate that pathology staff across Canada currently utilizes gross digital images for regular documentation and educational reasons. They also show that the technology will be needed for future applications in teaching, consultation and medico-legal purposes.

  1. 40 CFR 427.70 - Applicability; description of the asbestos floor tile subcategory.

    Science.gov (United States)

    2010-07-01

    ... asbestos floor tile subcategory. 427.70 Section 427.70 Protection of Environment ENVIRONMENTAL PROTECTION... Asbestos Floor Tile Subcategory § 427.70 Applicability; description of the asbestos floor tile subcategory... manufacture of asbestos floor tile. ...

  2. An education program about pelvic floor muscles improved women's knowledge but not pelvic floor muscle function, urinary incontinence or sexual function: a randomised trial.

    Science.gov (United States)

    de Andrade, Roberta Leopoldino; Bø, Kari; Antonio, Flavia Ignácio; Driusso, Patricia; Mateus-Vasconcelos, Elaine Cristine Lemes; Ramos, Salvador; Julio, Monica Pitanguy; Ferreira, Cristine Homsi Jorge

    2018-04-01

    Does an educational program with instructions for performing 'the Knack' improve voluntary contraction of the pelvic floor muscles, reduce reports of urinary incontinence, improve sexual function, and promote women's knowledge of the pelvic floor muscles? Randomised, controlled trial with concealed allocation, intention-to-treat analysis and blinded assessors. Ninety-nine women from the local community. The experimental group (n=50) received one lecture per week for 4 weeks, and instructions for performing 'the Knack'. The control group (n=49) received no intervention. The primary outcome was maximum voluntary contraction of the pelvic floor muscles measured using manometry. Secondary outcomes were: ability to contract the pelvic floor muscles measured using vaginal palpation; severity of urinary incontinence measured by the International Consultation on Incontinence Questionnaire-Short Form (ICIQ-SF) scored from 0 to 21; self-reported sexual function; and knowledge related to the pelvic floor. Outcomes were measured at baseline and after 4 weeks. The intervention did not significantly improve: maximum voluntary contraction (MD 2.7 cmH 2 O higher in the experimental group, 95% CI -0.5 to 5.9); ability to contract the pelvic floor muscles (RR 2.18, 95% CI 0.49 to 9.65); or self-reported severity of urinary incontinence (MD 1 point greater reduction in the experimental group, 95% CI -3 to 1). Sexual function did not significantly differ between groups, but very few of the women engaged in sexual activity during the study period. The educational program did, however, significantly increase women's knowledge related to the location, functions and dysfunctions of the pelvic floor muscles, and treatment options. Education and teaching women to perform 'the Knack' had no significant effect on voluntary contraction of the pelvic floor muscles, urinary incontinence or sexual function, but it promoted women's knowledge about the pelvic floor. Brazilian Registry of Clinical

  3. Generation of floor response spectra for PFBR RCB

    International Nuclear Information System (INIS)

    Sajish, S.D.; Ramakrishna, V.; Chellapandi, P.; Chetal, S.C.

    2003-01-01

    This paper describes the generation of floor time histories and corresponding floor response spectrums at various locations in reactor containment building (RCB) for 500 MWe Prototype Fast Breeder Reactor (PFBR). The RCB and its internal structures are modeled with equivalent 3D-beam elements (stick model), which have got the essential global stiffness and inertial properties of the corresponding building. The main aspect in the simulation of beam model is derivation of equivalent cross sectional properties such as bending, torsional and shear rigidities including shear centers. These properties have been obtained through 3D plate/shell element models with appropriate kinematic constraints, for the zones between floors of corresponding buildings. The stick model includes a set of springs and dampers to simulate soil effects, on which base raft and various sticks are mounted. The soil stiffness and damping values are derived based on equations given in ASCE-98. Time history analysis has been done using three uncorrelated time histories, which are derived from the site dependent design response spectra. Floor time histories (FTH) are extracted at important locations from which the corresponding floor response spectrums (FRS) have been generated for various damping values. Peak broadening of the response spectrums has been done according ASCE criteria. Floor response spectrum corresponds to reactor assembly support shows amplification 2.5 for SSE and 3 for OBE. CASTEM 3M is used for seismic analysis and generation of FRS. (author)

  4. Portable flooring protects finished surfaces, is easily moved

    Science.gov (United States)

    Carmody, R. J.

    1964-01-01

    To protect curved, finished surface and provide support for workmen, portable flooring has been made from rigid plastic foam blocks, faced with aluminum strips. Held together by nylon webbing, the flooring can be rolled up for easy carrying.

  5. Dance floors as injury risk: analysis and evaluation of acute injuries caused by dance floors in professional dance with regard to preventative aspects.

    Science.gov (United States)

    Wanke, Eileen M; Mill, Helmgard; Wanke, Alice; Davenport, Jaqueline; Koch, Franziska; Groneberg, David A

    2012-09-01

    A dance floor is often the only support of movements in dance. A dance floor surface that shows deficiencies, can result in acute injuries and chronic problems. Although the significance of an adequate dance floor is well known, there is still a lack of differentiated analyses of dance floor-related acute injuries. This study presents data on acute injuries exclusively caused by the dance floor. The data were obtained from standardized work accident reports from consultants (F 1000), documentary accident records from all Berlin theatres, a state ballet school (n=2,281), and case records from the Berlin State Accident Insurance (UKB) covering a period of 17 years. All analyses and descriptive statistics were conducted with Excel 2007 and SPSS 18. Dance floor surfaces were the causative factor in 12.8% of all accidents (n=291, female 183, male 108). Almost two thirds (62.6%) of all accidents in professional dancers happened on stage, and almost half (49.5%) occurred during performances. As for causative factors, 53.1% of the professional dancers (P) and 42.5% of the dance students (S) claimed that the floor had been "too slippery," with "getting stuck" or (tripping) as the second most common problem (P 18.4%, S 11.3%). Of the injured dancers, 41.8% were older than 30 years and can therefore be categorized as experienced. Dance floors play a significant role in the occurrence of acute injuries, even in experienced dancers. Performances on stage seem to be a particular risk. However, injury prevention measures should include all work locations (P) as well as non-dance-specific locations (S).

  6. 27 CFR 46.195 - Floor stocks requirements.

    Science.gov (United States)

    2010-04-01

    ... Tubes Held for Sale on April 1, 2009 General § 46.195 Floor stocks requirements. (a) Take inventory. The dealer must establish the quantity of articles subject to the floor stocks tax held for sale on April 1, 2009. The dealer may take a physical inventory or may use a record (book) inventory, as specified in...

  7. [Quality of life in women with pelvic floor dysfunction].

    Science.gov (United States)

    Segedi, Ljiljana Mladenović; Ilić, Katarina Parezanović; Curcić, Aleksandar; Visnjevac, Nemanja

    2011-11-01

    Pelvic floor dysfunction is a frequent problem affecting more than 50% of women in peri- and postmenopause. Considering that ageing and menopause befall in the significant factors causing this issue, as well as the expected longevity of women in the world and in our country, pelvic floor dysfunction prevelence is foreseen to be even higher. The aim of the study was to evaluate impact of the symptoms of pelvic dysfunction on quality of life and examine body image satisfaction in adult women with pelvic organ prolapse presenting to tertiary care clinic for surgical treatment. This prospective case-control study included 50 patients who presented to tertiary care gynecology clinic for surgical treatment and 50 controls with normal pelvic floor support and without urinary incontinence who presented tertiary care gynecology clinic for other reasons. Both, patients and controls, completed two quastionnaires recommended for the evaluation of symptoms (Pelvic floor distress inventory - short forms) and quality of life impact (Pelvic floor impact questionnaire - short form) of pelvic organ prolapse, and Body Image Scale. The patients scored significantly worse on the prolapse, urinary, colorectal scales and overall score of Pelvic floor distress inventory--20 than controls subjects (134.91 vs 78.08; p self-conscious (78% vs 42%; p body. There was a positive correlation between decreased quality of life and body image in women with pelvic dysfunction. Women with pelvic floor dysfunction have decreased quality of life and body image.

  8. Anonymous electronic trading versus floor trading

    OpenAIRE

    Franke, Günter; Hess, Dieter

    1995-01-01

    This paper compares the attractiveness of floor trading and anonymous electronic trading systems. It is argued that in times of low information intensity the insight into the order book of the electronic trading system provides more valuable information than floor trading, but in times of high information intensity the reverse is true. Thus, the electronic system's market share in trading activity should decline in times of high information intensity. This hypothesis is tested by data on BUND...

  9. Imaging of the posterior pelvic floor

    International Nuclear Information System (INIS)

    Stoker, Jaap; Bartram, Clive I.; Halligan, Steve

    2002-01-01

    Disorders of the posterior pelvic floor are relatively common. The role of imaging in this field is increasing, especially in constipation, prolapse and anal incontinence, and currently imaging is an integral part of the investigation of these pelvic floor disorders. Evacuation proctography provides both structural and functional information for rectal voiding and prolapse. Dynamic MRI may be a valuable alternative as the pelvic floor muscles are visualised, and it is currently under evaluation. Endoluminal imaging is important in the management of anal incontinence. Both endosonography and endoanal MRI can be used for detection of anal sphincter defects. Endoanal MRI has the advantage of simultaneously evaluating external sphincter atrophy, which is an important predictive factor for the outcome of sphincter repair. Many aspects of constipation and prolapse remain incompletely understood and treatment is partly empirical; however, imaging has a central role in management to place patients into treatment-defined groups. (orig.)

  10. Imaging of the posterior pelvic floor

    Energy Technology Data Exchange (ETDEWEB)

    Stoker, Jaap [Department of Radiology, Academic Medical Center, University of Amsterdam (Netherlands); Bartram, Clive I.; Halligan, Steve [Intestinal Imaging Centre, St. Mark' s Hospital, London (United Kingdom)

    2002-04-01

    Disorders of the posterior pelvic floor are relatively common. The role of imaging in this field is increasing, especially in constipation, prolapse and anal incontinence, and currently imaging is an integral part of the investigation of these pelvic floor disorders. Evacuation proctography provides both structural and functional information for rectal voiding and prolapse. Dynamic MRI may be a valuable alternative as the pelvic floor muscles are visualised, and it is currently under evaluation. Endoluminal imaging is important in the management of anal incontinence. Both endosonography and endoanal MRI can be used for detection of anal sphincter defects. Endoanal MRI has the advantage of simultaneously evaluating external sphincter atrophy, which is an important predictive factor for the outcome of sphincter repair. Many aspects of constipation and prolapse remain incompletely understood and treatment is partly empirical; however, imaging has a central role in management to place patients into treatment-defined groups. (orig.)

  11. Predictive multiscale computational model of shoe-floor coefficient of friction.

    Science.gov (United States)

    Moghaddam, Seyed Reza M; Acharya, Arjun; Redfern, Mark S; Beschorner, Kurt E

    2018-01-03

    Understanding the frictional interactions between the shoe and floor during walking is critical to prevention of slips and falls, particularly when contaminants are present. A multiscale finite element model of shoe-floor-contaminant friction was developed that takes into account the surface and material characteristics of the shoe and flooring in microscopic and macroscopic scales. The model calculates shoe-floor coefficient of friction (COF) in boundary lubrication regime where effects of adhesion friction and hydrodynamic pressures are negligible. The validity of model outputs was assessed by comparing model predictions to the experimental results from mechanical COF testing. The multiscale model estimates were linearly related to the experimental results (p < 0.0001). The model predicted 73% of variability in experimentally-measured shoe-floor-contaminant COF. The results demonstrate the potential of multiscale finite element modeling in aiding slip-resistant shoe and flooring design and reducing slip and fall injuries. Copyright © 2017 The Author(s). Published by Elsevier Ltd.. All rights reserved.

  12. Common floor system vertical earthquake-proof structure for reactor equipment

    International Nuclear Information System (INIS)

    Morishita, Masaki.

    1996-01-01

    In an LMFBR type reactor, a reactor container, a recycling pump and a heat exchanger are disposed on a common floor. Vertical earthquake-proof devices which can be stretched only in vertical direction formed by laminating large-sized bellevilles are disposed on a concrete wall at the circumference of each of reactor equipments. A common floor is placed on all of the vertical earthquake-proof devices to support the entire earthquake-proof structure simultaneously. If each of reactor equipments is loaded on the common floor and the common floor is entirely supported against earthquakes altogether, since the movement of each of the reactor equipments loaded on the common floor is identical, relative dislocation is not exerted on the main pipelines which connect the equipments. In addition, since the entire earthquake structure has a flat common floor and each of the reactor equipments is suspended to minimize the distance between a gravitational center and a support point, locking vibration is less caused to the horizontal earthquake. (N.H.)

  13. Functional imaging of the pelvic floor

    Energy Technology Data Exchange (ETDEWEB)

    Lienemann, Andreas E-mail: andreaslienemann@web.de; Fischer, Tanja

    2003-08-01

    Introduction/Objective: Pelvic floor dysfunction and associated pelvic organ prolapse represent a major problem in our present-day society, mostly afflicting parous women. Magnetic resonance imaging (MRI) is assuming an increasingly important role in the more accurate delineation of the extent of the problem. This article briefly reviews one of the main radiological methods for the dynamic evaluation of the pelvic floor: functional cine MRI. Methods and Material: Out of the literature the smallest common denominator for functional cine MRI can be defined as follows: high field system; patient either in supine or sitting position; fast gradient echo sequence; midsagittal slice orientation; either a stack of slices or repeated measurements at the same slice position with the patient at rest or straining; image analysis using the pubococcygeal reference line. Results: All except two publications stress the usefulness of functional cine MRI in the evaluation of patients with organ descent and prolapse. This well accepted method allows for the visualization of all relevant structures in the anterior, middle and posterior compartment. It is especially useful in the detection of enteroceles, and provides a reliable postoperative follow-up tool. Isolated urinary or stool incontinence are not an indication for functional cine MRI, as is the case in patients with equivocal clinical findings. To date it does not allow for real 3D imaging of the pelvic floor or sufficient determination of fascial defects. Discussion: Functional cine MRI of the pelvic floor is a promising new imaging method for the detection of organ descent and prolapse in patients with equivocal clinical findings. The combination of function and morphology allows for an innovative view of the pelvic floor, and thus adds to our understanding of the various interactions of the structures.

  14. Modelling floor heating systems using a validated two-dimensional ground coupled numerical model

    DEFF Research Database (Denmark)

    Weitzmann, Peter; Kragh, Jesper; Roots, Peter

    2005-01-01

    This paper presents a two-dimensional simulation model of the heat losses and tempera-tures in a slab on grade floor with floor heating which is able to dynamically model the floor heating system. The aim of this work is to be able to model, in detail, the influence from the floor construction...... the floor. This model can be used to design energy efficient houses with floor heating focusing on the heat loss through the floor construction and foundation. It is found that it is impor-tant to model the dynamics of the floor heating system to find the correct heat loss to the ground, and further......, that the foundation has a large impact on the energy consumption of buildings heated by floor heating. Consequently, this detail should be in focus when designing houses with floor heating....

  15. Do women with pelvic floor dysfunction referred by gynaecologists and urologists at hospitals complete a pelvic floor muscle training programme?

    DEFF Research Database (Denmark)

    Tibaek, Sigrid; Dehlendorff, Christian

    2013-01-01

    For decades women with pelvic floor dysfunction (PFD) have been referred to pelvic floor muscle training (PFMT), but there is only little information on whether the women complete the programmes and why. The objectives of this study were to investigate to which extent women completed a PFMT...

  16. Indoor radon seasonal variability at different floors of buildings

    International Nuclear Information System (INIS)

    De Francesco, S.; Tommasone, F. Pascale; Cuoco, E.; Tedesco, D.

    2010-01-01

    Indoor radon concentrations have been measured with the α track etch integrated method in public buildings in the town of Pietramelara, north-western Campania, Southern Italy. In particular, our measurements were part of an environmental monitoring program originally aimed at assessing the range of seasonal fluctuations in indoor radon concentrations, at various floors of the studied buildings. However, subsequent analysis of the data and its comparison with the meteorological data recorded in the same period has shown an unexpected pattern at the different floors. In this report we present data suggesting that, besides the well-known medium and longterm periodicity, there could also be a differentiation in major meteorological controlling factors at the different floors of the buildings, a fact that does not appear to have been reported previously. While the lower floors proved to be markedly affected by rainfall, for the upper floors, instead, a different behaviour has been detected, which could possibly be related to global solar radiation.

  17. Pelvic floor spasm as a cause of voiding dysfunction.

    Science.gov (United States)

    Kuo, Tricia L C; Ng, L G; Chapple, Christopher R

    2015-07-01

    Pelvic floor disorders can present with lower urinary tract symptoms, bowel, sexual dysfunction, and/or pain. Symptoms of pelvic muscle spasm (nonrelaxing pelvic floor or hypertonicity) vary and can be difficult to recognize. This makes diagnosis and management of these disorders challenging. In this article, we review the current evidence on pelvic floor spasm and its association with voiding dysfunction. To distinguish between the different causes of voiding dysfunction, a video urodynamics study and/or electromyography is often required. Conservative measures include patient education, behavioral modifications, lifestyle changes, and pelvic floor rehabilitation/physical therapy. Disease-specific pelvic pain and pain from pelvic floor spasm needs to be differentiated and treated specifically. Trigger point massage and injections relieves pain in some patients. Botulinum toxin A, sacral neuromodulation, and acupuncture has been reported in the management of patients with refractory symptoms. Pelvic floor spasm and associated voiding problems are heterogeneous in their pathogenesis and are therefore often underrecognized and undertreated; it is therefore essential that a therapeutic strategy needs to be personalized to the individual patient's requirements. Therefore, careful evaluation and assessment of individuals using a multidisciplinary team approach including a trained physical therapist/nurse clinician is essential in the management of these patients.

  18. Endoscopic anatomy of the orbital floor and maxillary sinus.

    Science.gov (United States)

    Moore, Corey C; Bromwich, Matthew; Roth, Kathy; Matic, Damir B

    2008-01-01

    Endoscopic repair of orbital blow-out fractures could become a predictable and efficient treatment alternative to traditional methods. However, maxillary sinus endoscopy provides a complex and disorienting view of the orbital floor. To be a useful and consistent technique for providing access to the orbital floor, specific knowledge of maxillary endoscopic anatomy is required. The purpose of the study was to provide an anatomic description of the orbital floor via the endoscopic approach. Objectives include defining consistent landmarks for use in endoscopic repair of orbital floor fractures. Using 0- and 30-degree rigid endoscopes, 6 fresh cadavers (12 maxillary sinuses) were examined via a standard Caldwell-Luc approach. Computed tomographic scans, plastic molds, and digital images were used to compare observable averages within bony anatomy. Potential bony landmarks were correlated with soft-tissue anatomy in fresh specimens. The maxillary ostium, orbital floor, and lateral ethmoid air cells were visualized, and their structures were described. Observations were made in relation to the anatomy of the orbital floor and maxillary sinus, including fracture pattern and force transmission pathways. An "orbitomaxillary" sinus bony thickening was identified and described for the first time. This study provides the basis for further refinement of surgical technique and opens the door for future clinical trials using endoscopic repair.

  19. Nuclear reactor cavity floor passive heat removal system

    Science.gov (United States)

    Edwards, Tyler A.; Neeley, Gary W.; Inman, James B.

    2018-03-06

    A nuclear reactor includes a reactor core disposed in a reactor pressure vessel. A radiological containment contains the nuclear reactor and includes a concrete floor located underneath the nuclear reactor. An ex vessel corium retention system includes flow channels embedded in the concrete floor located underneath the nuclear reactor, an inlet in fluid communication with first ends of the flow channels, and an outlet in fluid communication with second ends of the flow channels. In some embodiments the inlet is in fluid communication with the interior of the radiological containment at a first elevation and the outlet is in fluid communication with the interior of the radiological containment at a second elevation higher than the first elevation. The radiological containment may include a reactor cavity containing a lower portion of the pressure vessel, wherein the concrete floor located underneath the nuclear reactor is the reactor cavity floor.

  20. Comparison of changes in the mobility of the pelvic floor muscle on during the abdominal drawing-in maneuver, maximal expiration, and pelvic floor muscle maximal contraction

    OpenAIRE

    Jung, Halim; Jung, Sangwoo; Joo, Sunghee; Song, Changho

    2016-01-01

    [Purpose] The purpose of this study was to compare changes in the mobility of the pelvic floor muscle during the abdominal drawing-in maneuver, maximal expiration, and pelvic floor muscle maximal contraction. [Subjects] Thirty healthy adults participated in this study (15 men and 15 women). [Methods] All participants performed a bridge exercise and abdominal curl-up during the abdominal drawing-in maneuver, maximal expiration, and pelvic floor muscle maximal contraction. Pelvic floor mobility...

  1. Validation of the Pelvic Floor Distress Inventory-20 and the Pelvic Floor Impact Questionnaire-7 in Danish women with pelvic organ prolapse

    DEFF Research Database (Denmark)

    Due, Ulla; Brostrøm, Søren; Lose, Gunnar

    2013-01-01

    To translate the Pelvic Floor Distress Inventory-20 (PFDI-20) and the Pelvic Floor Impact Questionnaire-7 (PFIQ-7) and to evaluate their psychometric properties in Danish women with symptomatic pelvic organ prolapse....

  2. Development of rationalized system treating floor drain

    International Nuclear Information System (INIS)

    Nakamura, Yasuyuki; Serizawa, Kenichi; Komatsu, Akihiro; Shimizu, Takayuki

    1998-01-01

    Radioactive liquid wastes generated at BWR plants are collected and treated as required. These days, however, generation of floor drain has deceased and HFF (Hollow Fiber Filter) has experienced a wide applicability to several kinds of liquid wastes. We should consider that the floor drain can be mixed and diluted with equipment drain and be purified by HFF. That enables some of the sumps and long priming pipes to be combined. From this point of view, we have developed a highly rationalized waste liquid system. We have evaluated the applicability of this system after an investigation into the generation and properties of floor drain and equipment drain at the latest BWR'S and an on-site test at a typical BWR. (author)

  3. 26 CFR 1.61-14 - Miscellaneous items of gross income.

    Science.gov (United States)

    2010-04-01

    ... as treble damages under the antitrust laws and exemplary damages for fraud are gross income. Another... by law. Illegal gains constitute gross income. Treasure trove, to the extent of its value in United...

  4. Handling Uncertain Gross Margin and Water Demand in Agricultural Water Resources Management using Robust Optimization

    Science.gov (United States)

    Chaerani, D.; Lesmana, E.; Tressiana, N.

    2018-03-01

    In this paper, an application of Robust Optimization in agricultural water resource management problem under gross margin and water demand uncertainty is presented. Water resource management is a series of activities that includes planning, developing, distributing and managing the use of water resource optimally. Water resource management for agriculture can be one of the efforts to optimize the benefits of agricultural output. The objective function of agricultural water resource management problem is to maximizing total benefits by water allocation to agricultural areas covered by the irrigation network in planning horizon. Due to gross margin and water demand uncertainty, we assume that the uncertain data lies within ellipsoidal uncertainty set. We employ robust counterpart methodology to get the robust optimal solution.

  5. Flooring in front of the feed bunk affects feeding behavior and use of freestalls by dairy cows.

    Science.gov (United States)

    Tucker, C B; Weary, D M; de Passillé, A M; Campbell, B; Rushen, J

    2006-06-01

    In 2 experiments we assessed how preferences, time budgets, and feeding behavior of dairy cows change in response to flooring surfaces in front of the feed bunk. In Experiment 1, 12 nonlactating dairy cattle were individually housed with access to 2 standing platforms filled with either concrete or sawdust. In Experiment 2, 24 nonlactating dairy cattle were given access to either concrete or Animat rubber flooring in front of the feed bunk. In Experiment 1, cows preferred the sawdust to the concrete flooring. In both experiments, cows provided with a softer floor in front of the feed bunk spent more time standing near the feed bunk without eating (Experiment 1: 67 vs. 40 min/d on sawdust vs. concrete, respectively, SEM = 5.6 min/d; Experiment 2: 176 vs. 115 min/d on Animat vs. concrete, respectively, SEM = 20.5 min/d) compared with when they were kept on concrete. The increased time spent at the feed bunk was due to a combination of more frequent eating and standing bouts, indicating that cows were more willing to move on nonconcrete flooring. Total time spent eating was significantly greater on the softer floor in Experiment 2, but not in Experiment 1 (Exp. 1: 289 vs. 275 min/d on sawdust and concrete, respectively, SEM = 7.3 min/d; Exp. 2: 330 vs. 289 min/d on Animat and concrete, respectively, SEM = 15.4), although feed intake was increased on the sawdust treatment in Experiment 1. Cows spent significantly more time lying in the feed alley when the flooring was rubber (219 vs. 53 min/d on Animat and concrete, SEM = 53.6 min/d), perhaps because the lying area in Experiment 2 was inadequate. In conclusion, cows prefer to stand on softer flooring in front of the feed bunk, and are more willing to move on and spend more time standing in front of the feed bunk when provided with softer flooring. These results indicate that cows find softer flooring surfaces more comfortable to stand on than concrete, and highlight the importance of evaluating the comfort of the

  6. An education program about pelvic floor muscles improved women’s knowledge but not pelvic floor muscle function, urinary incontinence or sexual function: a randomised trial

    Directory of Open Access Journals (Sweden)

    Roberta Leopoldino de Andrade

    2018-04-01

    Full Text Available Question: Does an educational program with instructions for performing ‘the Knack’ improve voluntary contraction of the pelvic floor muscles, reduce reports of urinary incontinence, improve sexual function, and promote women’s knowledge of the pelvic floor muscles? Design: Randomised, controlled trial with concealed allocation, intention-to-treat analysis and blinded assessors. Participants: Ninety-nine women from the local community. Intervention: The experimental group (n = 50 received one lecture per week for 4 weeks, and instructions for performing ‘the Knack’. The control group (n = 49 received no intervention. Outcome measures: The primary outcome was maximum voluntary contraction of the pelvic floor muscles measured using manometry. Secondary outcomes were: ability to contract the pelvic floor muscles measured using vaginal palpation; severity of urinary incontinence measured by the International Consultation on Incontinence Questionnaire-Short Form (ICIQ-SF scored from 0 to 21; self-reported sexual function; and knowledge related to the pelvic floor. Outcomes were measured at baseline and after 4 weeks. Results: The intervention did not significantly improve: maximum voluntary contraction (MD 2.7 cmH2O higher in the experimental group, 95% CI –0.5 to 5.9; ability to contract the pelvic floor muscles (RR 2.18, 95% CI 0.49 to 9.65; or self-reported severity of urinary incontinence (MD 1 point greater reduction in the experimental group, 95% CI –3 to 1. Sexual function did not significantly differ between groups, but very few of the women engaged in sexual activity during the study period. The educational program did, however, significantly increase women’s knowledge related to the location, functions and dysfunctions of the pelvic floor muscles, and treatment options. Conclusion: Education and teaching women to perform ‘the Knack’ had no significant effect on voluntary contraction of the pelvic floor muscles

  7. 26 CFR 1.993-6 - Definition of gross receipts.

    Science.gov (United States)

    2010-04-01

    ... 26 Internal Revenue 10 2010-04-01 2010-04-01 false Definition of gross receipts. 1.993-6 Section 1.993-6 Internal Revenue INTERNAL REVENUE SERVICE, DEPARTMENT OF THE TREASURY (CONTINUED) INCOME TAX (CONTINUED) INCOME TAXES Domestic International Sales Corporations § 1.993-6 Definition of gross receipts. (a...

  8. Guidelines for Standard Photography in Gross and Clinical Anatomy

    Science.gov (United States)

    Barut, Cagatay; Ertilav, Hakan

    2011-01-01

    Photography has a widespread usage in medicine and anatomy. In this review, authors focused on the usage of photography in gross and clinical anatomy. Photography in gross and clinical anatomy is not only essential for accurate documentation of morphological findings but also important in sharing knowledge and experience. Photographs of cadavers…

  9. TEMPERATURE HETEROGENEITY OF TRAVELLING FIRE AND ITS INFLUENCE ON COMPOSITE STEEL-CONCRETE FLOOR

    Directory of Open Access Journals (Sweden)

    Kamila Horová

    2016-04-01

    Full Text Available In order to follow modern trends in contemporary building architecture, which is moving off the limits of current fire design models, assumption of homogeneous temperature conditions used for structural fire analysis needs to be revised. In this paper fire dynamics of travelling fire is investigated experimentally by conducting fire test in two-storey experimental building. To evaluate the impact of travelling fire on the mechanical behaviour of a structure, the spatial and temporal evolution of the gas temperature calculated in NIST code FDS, which was validated to experimental measurements, is applied to the composite floor of dimensions 9.0 m by 9.0 m. Mechanical behaviour of the composite slab highly affected by regions of high temperatures and areas with only elevated temperatures is solved in code Vulcan. To highlight the severity of spreading fire causing non-uniform temperature conditions, which after-effects differ from traditional methods, a comparison of both methods is introduced. The calculation of mechanical behaviour of the composite floor is repeated in a series of three different thermal loading cases. Results of all cases are then compared in terms of vertical displacement and axial force in several positions of the composite floor.

  10. Pelvic floor dyssynergia: efficacy of biofeedback training.

    Science.gov (United States)

    Gadel Hak, Nabil; El-Hemaly, Mohamed; Hamdy, Emad; El-Raouf, Ahmed Abd; Atef, Ehab; Salah, Tarek; El-Hanafy, Ehab; Sultan, Ahmad; Haleem, Magdy; Hamed, Hala

    2011-03-01

    Paradoxical contraction of the pelvic floor during attempts to defaecate is described as pelvic floor dyssynergia (anismus). It is a behavioural disorder (no associated morphological or neurological abnormalities); consequently, biofeedback training has been recommended as a behavioural therapy for such a disorder. The aim of the present study was to evaluate long-term satisfaction of patients diagnosed with pelvic floor dyssynergia after biofeedback. Sixty patients (35 females and 25 males) with a mean age of 30±12years and a 4year duration of constipation were included. Forty-five patients had normal colonic transit and 15 patients had slow colonic transit. History, physical examination and barium enema were done to exclude constipation secondary to organic causes. Colonic and pelvic floor functions (colon-transit time, anorectal manometry, EMG and defaecography) were performed before and after biofeedback treatments. Patients were treated on a weekly basis with an average of (6±2) sessions. At the end of sessions, 55 out of 60 patients (91.6%) reported a subjectively overall improvement. Symptoms of dyschezia were reported less frequently after biofeedback. Age and gender were not predictive factors of outcome. No symptoms at initial assessment were predictive for patient's satisfaction but the only factor of predictive value was the diagnosis of anismus and the motivated patient who wanted to continue the sessions. Biofeedback remains a morbidity free, low-cost and effective outpatient therapy for well-motivated patients complaining of functional constipation and diagnosed as pelvic floor dyssynergia. Copyright © 2011 Arab Journal of Gastroenterology. Published by Elsevier Ltd. All rights reserved.

  11. 120 Years of U.S. Residential Housing Stock and Floor Space

    Energy Technology Data Exchange (ETDEWEB)

    Pinto de Moura, Maria C.; Smith, Steven J.; Belzer, David B.

    2015-08-11

    Energy consumption in the residential sector accounts for one-fifth of total U.S. energy consumption and energy-related CO2 emissions. Floor space is a major driver of building energy demand. This paper develops a historical time series of total residential floor space for 1891-2010 and examines the role of socio-economic drivers GDP, population and household size on floor space. Using primarily data from the U.S. Census Bureau, we develop new construction and vintage-disaggregated housing stock for three building types, and address various data inconsistency issues. An examination of the long-term relationship of GDP and total residential floor space shows a remarkably constant trend over the period. While population increases five times over the period, a 50% decrease in household size contributes towards a tenfold increase in the number of housing units and floor space, while average floor space per unit remains surprisingly constant, as a result of housing retirement dynamics. In the last 30 years, however, these trends appear to be changing, as household size shows signs of leveling off, or even increasing again, while average floor space per unit has been increasing. Total residential sector primary energy consumption and floor space show a similar growth trend over the last 60 years.

  12. 76 FR 7098 - Dealer Floor Plan Pilot Program

    Science.gov (United States)

    2011-02-09

    ... Plan Pilot Program AGENCY: U.S. Small Business Administration (SBA). ACTION: Program implementation with request for comments. SUMMARY: SBA is introducing a new Dealer Floor Plan Pilot Program to make... Plan Pilot Program was created in the Small Business Jobs Act of 2010. Under the new Dealer Floor Plan...

  13. 49 CFR 38.99 - Floors, steps and thresholds.

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 1 2010-10-01 2010-10-01 false Floors, steps and thresholds. 38.99 Section 38.99 Transportation Office of the Secretary of Transportation AMERICANS WITH DISABILITIES ACT (ADA) ACCESSIBILITY SPECIFICATIONS FOR TRANSPORTATION VEHICLES Commuter Rail Cars and Systems § 38.99 Floors, steps and thresholds...

  14. Oropharyngeal dysphagia and gross motor skills in children with cerebral palsy.

    Science.gov (United States)

    Benfer, Katherine A; Weir, Kelly A; Bell, Kristie L; Ware, Robert S; Davies, Peter S W; Boyd, Roslyn N

    2013-05-01

    To determine the prevalence of oropharyngeal dysphagia (OPD) and its subtypes (oral phase, pharyngeal phase, saliva control), and their relationship to gross motor functional skills in preschool children with cerebral palsy (CP). It was hypothesized that OPD would be present across all gross motor severity levels, and children with more severe gross motor function would have increased prevalence and severity of OPD. Children with a confirmed diagnosis of CP, 18 to 36 months corrected age, born in Queensland between 2006 and 2009, participated. Children with neurodegenerative conditions were excluded. This was a cross-sectional population-based study. Children were assessed by using 2 direct OPD measures (Schedule for Oral Motor Assessment; Dysphagia Disorders Survey), and observations of signs suggestive of pharyngeal phase impairment and impaired saliva control. Gross motor skills were described by using the Gross Motor Function Measure, Gross Motor Function Classification System (GMFCS), Manual Ability Classification System, and motor type/ distribution. OPD was prevalent in 85% of children with CP, and there was a stepwise relationship between OPD and GMFCS level. There was a significant increase in odds of having OPD, or a subtype, for children who were nonambulant (GMFCS V) compared with those who were ambulant (GMFCS I) (odds ratio = 17.9, P = .036). OPD was present across all levels of gross motor severity using direct assessments. This highlights the need for proactive screening of all young children with CP, even those with mild impairments, to improve growth and nutritional outcomes and respiratory health.

  15. "Help Me Pull That Cursor" A Collaborative Interactive Floor Enhancing Community Interaction

    Directory of Open Access Journals (Sweden)

    Peter Krogh

    2004-05-01

    Full Text Available In this paper we describe the development, experiments and evaluation of the iFloor, an interactive floor prototype installed at the local central municipality library. The primary purpose of the iFloor prototype is to support and stimulate community interaction between collocated people. The context of the library demands that any user can walk up and use the prototype without any devices or prior introduction. To achieve this, the iFloor proposes innovative interaction (modes/paradigms/patterns for floor surfaces through the means of video tracking. Browsing and selecting content is done in a collaborative process and mobile phones are used for posting messages onto the floor. The iFloor highlights topics on social issues of ubiquitous computing environments in public spaces, and provides an example of how to exploit human spatial movements, positions and arrangements in interaction with computers.

  16. Effects of different flooring options in outside pens of hutches on dairy calf growth

    Science.gov (United States)

    Growth rates of dairy calves may vary due to many different factors, including housing. The objective of this study was to determine if calf growth was affected by different flooring options in the outside penned area of a calf hutch. For this study, 33 hutches were blocked in groups of 3 by locatio...

  17. A Method of Assembling Wall or Floor Elements

    DEFF Research Database (Denmark)

    2002-01-01

    The invention relates to a method of constructing, at the site of use, a building wall (1) or a building floor (1) using a plurality of prefabricated concrete or lightweight concrete plate-shaped wall of floor elements (10), in particular cast elements, which have a front side and a rear side...

  18. 120 Years of U.S. Residential Housing Stock and Floor Space.

    Directory of Open Access Journals (Sweden)

    Maria Cecilia P Moura

    Full Text Available Residential buildings are a key driver of energy consumption and also impact transportation and land-use. Energy consumption in the residential sector accounts for one-fifth of total U.S. energy consumption and energy-related CO2 emissions, with floor space a major driver of building energy demands. In this work a consistent, vintage-disaggregated, annual long-term series of U.S. housing stock and residential floor space for 1891-2010 is presented. An attempt was made to minimize the effects of the incompleteness and inconsistencies present in the national housing survey data. Over the 1891-2010 period, floor space increased almost tenfold, from approximately 24,700 to 235,150 million square feet, corresponding to a doubling of floor space per capita from approximately 400 to 800 square feet. While population increased five times over the period, a 50% decrease in household size contributed towards a tenfold increase in the number of housing units and floor space, while average floor space per unit remains surprisingly constant, as a result of housing retirement dynamics. In the last 30 years, however, these trends appear to be changing, as household size shows signs of leveling off, or even increasing again, while average floor space per unit has been increasing. GDP and total floor space show a remarkably constant growth trend over the period and total residential sector primary energy consumption and floor space show a similar growth trend over the last 60 years, decoupling only within the last decade.

  19. Laying hen movement in a commercial aviary: Enclosure to floor and back again.

    Science.gov (United States)

    Campbell, D L M; Makagon, M M; Swanson, J C; Siegford, J M

    2016-01-01

    Many producers in the laying hen industry, including in North America, are phasing out conventional cages in response to consumer demands and sometimes subsequent legislation. Alternative housing systems such as aviaries are being implemented in an attempt to improve hen welfare. Aviaries provide additional space and resources to groups of hens, including a litter area on the floor. However, little is known about hen movement between tiered enclosures and floor litter areas in aviary systems. Diurnal rhythms and social attraction may result in peak times of movement that could lead to overcrowding of areas, or alternatively hen preferences may lead to some areas not being fully utilized. We monitored hen movement between tiered enclosures and litter areas, including movement on and off the outer perch, across the day at peak, mid and end of lay in a commercial aviary. Hens moved onto and off of the open litter area across the day, transitioning between tiered enclosures, outer perches, open litter areas, and litter areas under tiered enclosures. At certain times of day, there were periods of greater hen movement down to the open litter area and between litter areas. For example, more hens were typically observed exiting enclosures, jumping from perches to open litter, and traveling between open litter and litter under tiered enclosures in the morning (all P ≤ 0.001). In all but one instance, more hens were observed on open litter areas in the afternoon than at other times of day (all P ≤ 0.029). However, hen re-entry to tiered enclosures showed less circadian patterning. Hen movement was observed between areas of interest at all sampled time periods, indicating hens use all areas of the system. Further research should examine whether all individual hens do move between areas equally, including within levels of the tiered enclosure, or if crowding occurs on the outer perches or in the litter during times of peak movement. © 2015 Poultry Science Association Inc.

  20. Floor-fractured craters on Ceres and implications for interior processes

    Science.gov (United States)

    Buczkowski, Debra; Schenk, Paul M.; Scully, Jennifer E. C.; Park, Ryan; Preusker, Frank; Raymond, Carol; Russell, Christopher T.

    2016-10-01

    Several of the impact craters on Ceres have patterns of fractures on their floors. These fractures appear similar to those found within a class of lunar craters referred to as Floor-Fractured Craters (FFCs) [Schultz, 1976].Lunar FFCs are characterized by anomalously shallow floors cut by radial, concentric, and/or polygonal fractures, and have been classified into crater classes, Types 1 through 6, based on their morphometric properties [Schultz, 1976; Jozwiak et al, 2012, 2015]. Models for their formation have included both floor uplift due to magmatic intrusion below the crater or floor shallowing due to viscous relaxation. However, the observation that the depth versus diameter (d/D) relationship of the FFCs is distinctly shallower than the same association for other lunar craters supports the hypotheses that the floor fractures form due to shallow magmatic intrusion under the crater [Jozwiak et al, 2012, 2015].FFCs have also been identified on Mars [Bamberg et al., 2014]. Martian FFCs exhibit morphological characteristics similar to the lunar FFCs, and analyses suggest that the Martian FCCs also formed due to volcanic activity, although heavily influenced by interactions with groundwater and/or ice.We have cataloged the Ceres FFCs according to the classification scheme designed for the Moon. Large (>50 km) Ceres FFCs are most consistent with Type 1 lunar FFCs, having deep floors, central peaks, wall terraces, and radial and/or concentric fractures. Smaller craters on Ceres are more consistent with Type 4 lunar FFCs, having less-pronounced floor fractures and a v-shaped moats separating the wall scarp from the crater interior.An analysis of the d/D ratio for Ceres craters shows that, like lunar FFCs, the Ceres FFCs are anomalously shallow. This suggests that the fractures on the floor of Ceres FFCs may be due the intrusion of a low-density material below the craters that is uplifting their floors. While on the Moon and Mars the intrusive material is hypothesized

  1. Simulation study on single family house with solar floor and domestic hot water heating system by EESLISM; EESLISM ni yoru taiyonetsu danbo kyuto jutaku no simulation

    Energy Technology Data Exchange (ETDEWEB)

    Roh, H; Udagawa, M [Kogakuin University, Tokyo (Japan)

    1997-11-25

    Indoor thermal conditions and energy performance were simulated, by the aid of EESLISM as a common simulation program for indoor thermal conditions and energy systems, for an actual two-storied single family house equipped with solar-heated floors and a domestic hot water (DHW) heating system, in order to investigate applicability of the simulation program. The house, built in Shibuya Ward in Tokyo, has a total floor area of 164m{sup 2}, with a living room, dining room and study heated by the solar system for a total floor area of 35m{sup 2}. A heat-storage tank is provided, dedicated to the DHW system. The solar collector is of flat type, with selectively light-absorbing planes, having a total collector area of 11.46m{sup 2}. The operating conditions of the floor-heating and DHW systems are almost reproduced. It is necessary to take surrounding conditions into consideration; solar radiation in daytime will be overestimated if adjacent buildings are neglected to give higher temperature in the space and on the wall on the south than the observed level. 6 refs., 5 figs., 1 tab.

  2. Comparison between dynamic cystocolpoproctography and dynamic pelvic floor MRI: pros and cons: which is the "functional" examination for anorectal and pelvic floor dysfunction?

    Science.gov (United States)

    Maglinte, Dean D T; Hale, Douglass S; Sandrasegaran, Kumar

    2013-10-01

    "Functional" imaging of anorectal and pelvic floor dysfunction has assumed an important role in the diagnosis and management of these disorders. Although defecography has been widely practiced for decades to evaluate the dynamics of rectal emptying, debate concerning its clinical relevance, how it should be done and interpreted continues. Due to the recognition of the association of defecatory disorders with pelvic organ prolapse in women, the need to evaluate the pelvic floor as a unit has arisen. To meet this need, defecography has been extended to include not only evaluation of defecation disorders but also the rest of the pelvic floor by opacifying the small bowel, vagina, and the urinary bladder. The term "dynamic cystocolpoproctography" (DCP) has been appropriately applied to this examination. Rectal emptying performed with DCP provides the maximum stress to the pelvic floor resulting in complete levator ani relaxation. In addition to diagnosing defecatory disorders, this method of examination demonstrates maximum pelvic organ descent and provides organ-specific quantification of organ prolapse, information that is only inferred by means of physical examination. It has been found to be of clinical value in patients with defecation disorders and the diagnosis of associated prolapse in other compartments that are frequently unrecognized by history taking and the limitations of physical examination. Pelvic floor anatomy is complex and DCP does not show the anatomical details pelvic magnetic resonance imaging (MRI) provides. Technical advances allowing acquisition of dynamic rapid MRI sequences has been applied to pelvic floor imaging. Early reports have shown that pelvic MRI may be a useful tool in pre-operative planning of these disorders and may lead to a change in surgical therapy. Predictions of hypothetical increase cancer incidence and deaths in patients exposed to radiation, the emergence of pelvic floor MRI in addition to questions relating to the

  3. Chronic pelvic floor dysfunction.

    Science.gov (United States)

    Hartmann, Dee; Sarton, Julie

    2014-10-01

    The successful treatment of women with vestibulodynia and its associated chronic pelvic floor dysfunctions requires interventions that address a broad field of possible pain contributors. Pelvic floor muscle hypertonicity was implicated in the mid-1990s as a trigger of major chronic vulvar pain. Painful bladder syndrome, irritable bowel syndrome, fibromyalgia, and temporomandibular jaw disorder are known common comorbidities that can cause a host of associated muscular, visceral, bony, and fascial dysfunctions. It appears that normalizing all of those disorders plays a pivotal role in reducing complaints of chronic vulvar pain and sexual dysfunction. Though the studies have yet to prove a specific protocol, physical therapists trained in pelvic dysfunction are reporting success with restoring tissue normalcy and reducing vulvar and sexual pain. A review of pelvic anatomy and common findings are presented along with suggested physical therapy management. Copyright © 2014 Elsevier Ltd. All rights reserved.

  4. Smart Floor with Integrated Triboelectric Nanogenerator As Energy Harvester and Motion Sensor.

    Science.gov (United States)

    He, Chuan; Zhu, Weijun; Chen, Baodong; Xu, Liang; Jiang, Tao; Han, Chang Bao; Gu, Guang Qin; Li, Dichen; Wang, Zhong Lin

    2017-08-09

    A smart floor is demonstrated by integrating a square-frame triboelectric nanogenerator (SF-TENG) into a standard wood floor. The smart floor has two working modes based on two pairs of triboelectric materials: one is purposely chosen polytetrafluoroethylene films and aluminum (Al) balls, and the other is the floor itself and the objects that can be triboelectrically charged, such as basketball, shoe soles, and Scotch tape, etc. Utilizing the Al balls enclosed inside shallow boxes, the smart floor is capable of harvesting vibrational energy and, hence, provides a nonintrusive way to detect sudden falls in elderly people. In addition, when the basketball is bounced repeatedly on the floor, the average output voltage and current are 364 ± 43 V and 9 ± 1 μA, respectively, and 87 serially connected light-emitting diodes can be lit up simultaneously. Furthermore, the friction between the triboelectrically chargeable objects and the floor can also induce an alternating current output in the external circuit without the vibration of the Al balls. Normal human footsteps on the floor produce a voltage of 238 ± 17 V and a current of 2.4 ± 0.3 μA. Therefore, this work presents a smart floor with built-in SF-TENG without compromising the flexibility and stability of the standard wood floor and also demonstrates a way to harvest ambient energy solely by using conventional triboelectric materials in our daily life.

  5. Lead exposures from varnished floor refinishing.

    Science.gov (United States)

    Schirmer, Joseph; Havlena, Jeff; Jacobs, David E; Dixon, Sherry; Ikens, Robert

    2012-01-01

    We evaluated the presence of lead in varnish and factors predicting lead exposure from floor refinishing and inexpensive dust suppression control methods. Lead in varnish, settled dust, and air were measured using XRF, laboratory analysis of scrape and wipe samples, and National Institute for Occupational Safety and Health (NIOSH) Method 7300, respectively, during refinishing (n = 35 homes). Data were analyzed using step-wise logistic regression. Compared with federal standards, no lead in varnish samples exceeded 1.0 mg/cm(2), but 52% exceeded 5000 ppm and 70% of settled dust samples after refinishing exceeded 40 μg/ft(2). Refinishing pre-1930 dwellings or stairs predicted high lead dust on floors. Laboratory analysis of lead in varnish was significantly correlated with airborne lead (r = 0.23, p = 0.014). Adding dust collection bags into drum sanders and HEPA vacuums to edgers and buffers reduced mean floor lead dust by 8293 μg Pb/ft(2) (pairborne lead exposures to less than 50 μg/m(3). Refinishing varnished surfaces in older housing produces high but controllable lead exposures.

  6. Evaluation of free i-applications for tertiary level gross anatomy education

    Directory of Open Access Journals (Sweden)

    Matthew F. Pollard

    2012-04-01

    Full Text Available BackgroundThe use of electronic resources in education, including i-applications used on portable handheld devices, is increasing. Apple® handheld devices are popular, with free applications the most prevalent download form. Many gross anatomy i-applications are available, however no information on the quality of free anatomy products is available. Rating such products could therefore guide product recommendations.AimTo evaluate the quality and range of free iPod® applications that are applicable for tertiary level gross anatomy education.MethodsA search of the iTunes® Application Store with keywords anatomy, free, medical, functional, clinical, gross, and human was performed, with inclusion based on free applications containing human gross anatomy usable for tertiary education purposes. Application specification was noted; each was trialled independently and rated for usability, specification, academic level, and quality (image and programme.ResultsSixty-three applications were identified and eleven met inclusion criteria. Two provided gross anatomy of the entire body, nine examined specific regions or systems. Five were judged introductory in academic level, five intermediate, and one advanced. One application was rated low quality, and four excellent. None were considered difficult to use (six easy, five medium. Application size ranged between 1.2MB and 229MB (mean 27MB.ConclusionsThere are few free i-applications for learning gross anatomy and most concentrate on individual body systems, with the academic level and usability of all products well rated. Results suggest some free I-applications could be suitable adjuncts for gross anatomy education at both an undergraduate and graduate level.

  7. Wind-Eroded Crater Floors and Intercrater Plains, Terra Sabaea, Mars

    Science.gov (United States)

    Irwin, Rossman P.; Wray, James J.; Mest, Scott C.; Maxwell, Ted A.

    2018-02-01

    Ancient impact craters with wind-eroded layering on their floors provide a record of resurfacing materials and processes on early Mars. In a 54 km Noachian crater in Terra Sabaea (20.2°S, 42.6°E), eolian deflation of a friable, dark-toned layer up to tens of meters thick has exposed more resistant, underlying light-toned material. These layers differ significantly from strata of similar tone described in other regions of Mars. The light-toned material has no apparent internal stratification, and visible/near-infrared spectral analysis suggests that it is rich in feldspar. Its origin is ambiguous, as we cannot confidently reject igneous, pyroclastic, or clastic alternatives. The overlying dark-toned layer is probably a basaltic siltstone or sandstone that was emplaced mostly by wind, although its weak cementation and inverted fluvial paleochannels indicate some modification by water. Negative-relief channels are not found on the crater floor, and fluvial erosion is otherwise weakly expressed in the study area. Small impacts onto this crater's floor have exposed deeper friable materials that appear to contain goethite. Bedrock outcrops on the crater walls are phyllosilicate bearing. The intercrater plains contain remnants of a post-Noachian thin, widespread, likely eolian mantle with an indurated surface. Plains near Hellas-concentric escarpments to the north are more consistent with volcanic resurfacing. A 48 km crater nearby contains similar dark-over-light outcrops but no paleochannels. Our findings indicate that dark-over-light stratigraphy has diverse origins across Mars and that some dark-toned plains with mafic mineralogy are not of igneous origin.

  8. Gross alpha and beta activities in drinking water from Goias State, Brazil

    Energy Technology Data Exchange (ETDEWEB)

    Mingote, Raquel M. [Centro de Desenvolvimento da Tecnologia Nuclear (CDTN/CNEN), Belo Horizonte, MG (Brazil); Nogueira, Regina A.; Costa, Heliana F. da, E-mail: raquel.mingote@cdtn.br, E-mail: rnogueira@cnen.gov.br, E-mail: heliana@cnen.gov.br [Centro Regional de Ciencias Nucleares do Centro-Oeste (CRCN-CO/CNEN), Abadia de Goias, GO (Brazil). Parque Estadual Telma Ortegal

    2017-07-01

    Detection of gross alpha and beta radioactivity is important for a quick surveying of both natural and anthropogenic radioactivity in water. Furthermore, gross alpha and gross beta parameters are included in Brazilian legislation on quality of drinking water. In this work, a low background liquid scintillation spectrometer was used to simultaneously determine gross alpha and gross beta in samples of the public water supplies in the state of Goias, Brazil, during 2010-2015. Sample preparation involved evaporation to concentrate the sample ten-fold. The results indicate that the water meets the radioactivity standards required by the regulations MS 2914/2011 of the Brazilian Department of Health. Concerning the high level of censored observations, a statistical treatment of data was conducted by using analysis methods of censored data to provide a reference value of the gross alpha and beta radioactivity in drinking water from the state of Goias. The estimated typical activities are very low, 0.030 Bq•L{sup -1} and 0.058 Bq•L{sup -1}, respectively. (author)

  9. Dance floor mechanical properties and dancer injuries in a touring professional ballet company.

    Science.gov (United States)

    Hopper, Luke S; Allen, Nick; Wyon, Matthew; Alderson, Jacqueline A; Elliott, Bruce C; Ackland, Timothy R

    2014-01-01

    The mechanical properties of the floors used by dancers have often been suggested to be associated with injury, yet limited etiological evidence is available to support this hypothesis. The dance floors at three theatres regularly used by a touring professional ballet company were mechanically quantified with the aim of comparing floor properties with injury incidence in dancers. Cross sectional. Test points on the floors were quantified in accordance with European Sports Surface Standard protocols for force reduction. Injuries and associated variables occurring within the ballet company dancers during activity on the three floors were recorded by the company's medical staff. An injury was recorded if a dancer experienced an incident that restricted the dancer from performing all normal training or performance activities for a 24 h period. Injuries were delimited to those occurring in the lower limbs or lumbar region during non-lifting tasks. Floor construction varied between venues and a range of floor mechanical properties were observed. None of the floors complied with the range of force reduction values required by the European Sport Surface Standards. The highest injury rate was observed on the floor with the greatest variability of force reduction magnitudes. No difference in injury frequency was observed between the venues with the highest and lowest mean force reduction magnitudes. Professional dancers can be required to perform on floors that may be inadequate for safe dance practice. Intra-floor force reduction variability may have a stronger association with injury risk than mean floor force reduction magnitude. Copyright © 2013 Sports Medicine Australia. Published by Elsevier Ltd. All rights reserved.

  10. Dual-stiffness flooring: can it reduce fracture rates associated with falls?

    Science.gov (United States)

    Knoefel, Frank; Patrick, Louise; Taylor, Jodie; Goubran, Rafik

    2013-04-01

    Falls cause significant morbidity and mortality in long term care facilities. Dual-stiffness flooring (DSF) has previously shown promise in reducing such morbidity in experimental models. This study set out to measure the impact of SmartCell flooring on falls-related morbidity in a nursing home. All falls occurring at an Arizona nursing home between July 1, 2008, and December 31, 2010, were reviewed for age, sex, diagnosis of osteoporosis, number of medications, history of previous falls, type of flooring (normal vs DSF), time of day, type of injury, and resulting actions. Fall-related outcomes were compared across room types using chi-square and logistic regression methods. Eighty-two falls on the DSF were compared with 85 falls on the regular floor. There was a tendency for residents falling on DSF to have less bruising and abrasions, while having more redness and cuts. There were 2 fractures on regular flooring (2.4% fracture rate) and none on the DSF flooring (0% fracture rate). The fracture rate of 2.4% of falls on the regular floor is consistent with previous reports in the literature, whereas a 0% rate found on the DSF floor is a clinically significant improvement. This suggests that DSF may be a practical approach for institutions and consumers to reduce fall-related injuries. A larger scale controlled study to confirm these encouraging preliminary findings is warranted. Copyright © 2013 American Medical Directors Association, Inc. Published by Elsevier Inc. All rights reserved.

  11. Incident radiation and the allocation of nitrogen within Arctic plant canopies: implications for predicting gross primary productivity

    NARCIS (Netherlands)

    Street, L.E.; Shaver, G.R.; Rastetter, E.B.; Wijk, van M.T.; Kaye, B.A.; Williams, M.

    2012-01-01

    Arctic vegetation is characterized by high spatial variability in plant functional type (PFT) composition and gross primary productivity (P). Despite this variability, the two main drivers of P in sub-Arctic tundra are leaf area index (LT) and total foliar nitrogen (NT). LT and NT have been shown to

  12. Photographs of the Sea floor Offshore of New York and New Jersey

    Science.gov (United States)

    Butman, Bradford; Gutierrez, Benjamin T.; Buchholtz ten Brink, Marilyn R.; Schwab, William S.; Blackwood, Dann S.; Mecray, Ellen L.; Middleton, Tammie J.

    2003-01-01

    This DVD-ROM contains photographs of the sea floor and sediment texture data collected as part of studies carried out by the U.S. Geological Survey (USGS) in the New York Bight (Figure 1a (PDF format)). The studies were designed to map the sea floor (Butman, 1998, URL: http://pubs.usgs.gov/fs/fs133-98/) and to develop an understanding of the transport and long-term fate of sediments and associated contaminants in the region (Mecray and others, 1999, URL: http://pubs.usgs.gov/fs/fs114-99/). The data were collected on four research cruises carried out between 1996 and 2000 (Appendix I). The images and texture data were collected to provide direct observations of the sea floor geology and to aid in the interpretation of backscatter intensity data obtained from sidescan sonar and multibeam surveys of the sea floor. Preliminary descriptions of the sea floor geology in this region may be found in Schwab and others (2000, URL: http://pubs.usgs.gov/of/of00-295/; 2003), Butman and others (1998, URL: http://pubs.usgs.gov/of/of98-616/.), and Butman and others (2002, URL: http://pubs.usgs.gov/of/of00-503/). Schwab and others (2000 URL: http://pubs.usgs.gov/of/of00-295/; 2003) have identified 11 geologic units in New York Bight (Figure 2 (PDF format)). These units identify areas of active sediment transport, extensive anthropogenic influence on the sea floor, and various geologic units. Butman and others (2003) and Harris and others (in press) present the results of a moored array experiment carried out in the Hudson Shelf Valley to investigate the transport of sediments during winter. Summaries of these and other studies may be found at USGS studies in the New York Bight (URL: http://woodshole.er.usgs.gov/project-pages/newyork/). This DVD-ROM contains digital images of bottom still photographs, images digitized from videos, sediment grain-size analysis results, and short QuickTime movies from video transects. The data are presented in tabular form and in an ESRI (Environmental

  13. Awareness and timing of pelvic floor muscle contraction, pelvic exercises and rehabilitation of pelvic floor in lifelong premature ejaculation: 5 years experience

    Directory of Open Access Journals (Sweden)

    Giuseppe La Pera

    2014-06-01

    Full Text Available Objectives: To assess the cure rate of patients with premature ejaculation who underwent a treatment involving: 1 awareness of the pelvic floor muscles 2 learning the timing of execution and maintenance of contraction of the pelvic floor muscles during the sensation of the pre-orgasmic phase 3 pelvic floor rehabilitation (bio feed back, pelvic exercises and electrostimulation. Materials and methods: We recruited 78 patients with lifelong premature ejaculation who completed the training. The patients were informed of the role of the pelvic floor. They were taught to carry out the execution and maintenance of contraction of the pelvic floor muscles during the sensation of the pre-orgasmic phase to control the ejaculatory reflex. In order to improve the awareness, the tone and the endurance of the pelvic floor muscles, patients were treated with the rehabilitation of pelvic floor (RPF consisting mainly in biofeedback, pelvic exercises and in some cases also in electro-stimulation (ES. The training was carried out for a period of about 2-6 months with an average of 2-5 visits per cycle. Results: 54% of patients who completed the training were cured of premature ejaculation and learned over time to be able to postpone the ejaculation reflex. In a subgroup of 26 patients was also measured the IELT which on the average increased from < 2 minutes to >10 minutes. The best results occurred mainly in patients aged less than 35 where the cure rate was 65%. There were no side effects. Conclusions: In this study, approximately half of patients with premature ejaculation were cured after applying the above treatment.This therapy, necessitates a fairly long period of time (2-6 months and a great commitment on the part of the patient, nevertheless it can be a valid and effective treatment for patients with premature ejaculation. This treatment makes the patient independent in that he is not bound to specific times for taking medication. Furthermore there are no

  14. Associations between gross motor skills and physical activity in Australian toddlers.

    Science.gov (United States)

    Veldman, Sanne L C; Jones, Rachel A; Santos, Rute; Sousa-Sá, Eduarda; Pereira, João R; Zhang, Zhiguang; Okely, Anthony D

    2018-08-01

    Physical activity can be promoted by high levels of gross motor skills. A systematic review found a positive relationship in children (3-18 years) but only few studies examined this in younger children. The aim of this study was to examine the association between gross motor skills and physical activity in children aged 11-29 months. Cross-sectional study. This study involved 284 children from 30 childcare services in NSW, Australia (Mean age=19.77±4.18months, 53.2% boys). Physical activity was measured using accelerometers (Actigraph GT3X+). Gross motor skills were assessed using the Peabody Developmental Motor Scales Second Edition (PDMS-2). Multilevel linear regression analyses were computed to assess associations between gross motor skills and physical activity, adjusting for sex, age and BMI. Children spent 53.08% of their time in physical activity and 10.39% in moderate to vigorous physical activity (MVPA). Boys had higher total physical activity (pskills score was 96.16. Boys scored higher than girls in object manipulation (pskills and total physical activity or MVPA. Although gross motor skills were not associated with physical activity in this sample, stronger associations are apparent in older children. This study therefore highlights a potential important age to promote gross motor skills. Copyright © 2017 Sports Medicine Australia. Published by Elsevier Ltd. All rights reserved.

  15. Resident's Floor Level Preference in High-Rise Residential Buildings in China: A Case Study of Shijiazhuang City,Hebei Province

    Institute of Scientific and Technical Information of China (English)

    Sun Pingjun; Wang Ying; Pang Ruiqiu; Song Xinyan

    2016-01-01

    With the constant advance of global urbanization and aggravation of urban construction land scarcity,high-rise residential buildings have become one of the main carriers of urban residential function on account of both land saving and large housing requirement.However,relevant studies on consumers' floor selection preference in high-rise residential buildings,regarding what inherent and regular features and causes it has,are still insufficient,despite that related issues have important practical significance for real estate developers and designers' decision making in terms of dwelling size ratio,floor area,indoor layout,and so on.This study,based on systematic examination of existing domestic and international researches,seeks to make empirical tests and generalization on the above issues from the aspect of"utility function" (safety,comfortableness,accessibility and economic efficiency) of the living environment that impacted by different floor levels,and floor selection features regarding consumers' social and family structure attributes,as well as the intrinsic correlation between them.The results show the existence of floor level preference in high-rise residential buildings.Its essence is a personalized characterization of consumers' social and family structures' attributes in selecting the "utility function" of the living environment,as the preference value differs under various attributes including gender,age,income,family members and others.

  16. The architectural foundations for agent-based shop floor control

    DEFF Research Database (Denmark)

    Langer, Gilad; Bilberg, Arne

    1998-01-01

    simulation and cell controlenabling technologies. In order to continuethis research effortnew concepts and theories for shop floor control are investigated.This paper reviews the multi-agent concept aimed at investigatingits potential use in shop floor control systems. The paper willalso include a survey...

  17. Impact of the buildings areas on the fire incidence.

    Science.gov (United States)

    Srekl, Jože; Golob, Janvit

    2010-03-01

    A survey of statistical studies shows that probability of fires is expressed by the equation P(A) = KAα, where A = total floor area of the building and K and  are constants for an individual group, or risk category. This equation, which is based on the statistical data on fires in Great Britain, does not include the impact factors such as the number of employees and the activities carried out in these buildings. In order to find out possible correlations between the activities carried out in buildings, the characteristics of buildings and number of fires, we used a random sample which included 134 buildings as industrial objects, hotels, restaurants, warehouses and shopping malls. Our study shows that the floor area of buildings has low impact on the incidence of fires. After analysing the sample of buildings by using multivariate analysis we proved a correlation between the number of fires, floor area of objects, work operation period (per day) and the number of employees in objects.

  18. Compliant flooring for fall injury prevention in long-term care

    OpenAIRE

    Lachance, Chantelle

    2017-01-01

    A promising strategy for reducing the incidence and severity of fall-related injuries in long-term care (LTC) is to decrease the ground surface stiffness, and the subsequent forces applied to the body parts at impact, through installation of compliant flooring. Evidence about the feasibility of compliant flooring in LTC is extremely limited. My PhD research addresses this gap by conducting a comprehensive, multimethod evaluation of compliant flooring. Specifically, I investigate the feasibili...

  19. Thermal analysis of a double layer phase change material floor

    International Nuclear Information System (INIS)

    Jin Xing; Zhang Xiaosong

    2011-01-01

    Phase change materials (PCMs) can be used to shift the cooling or heating load from the peak period to the off-peak period. In this paper, a new double layer phase change material (PCM) floor is put forward. The two layers of PCM have different melting temperature. The system is used to store heat or cold energy in the off-peak period and release them in the peak period during heating or cooling. According to the numerical model built in this paper, the thermal performances of the floor are analyzed. The results show that the optimal melting temperatures of PCMs exist. The fluctuations of the floor surface temperatures and the heat fluxes will be reduced and the system still can provide a certain amount of heat or cold energy after the heat pump or chiller has been turned off for a long time. Compared to the floor without PCM, the energy released by the floor with PCM in peak period will be increased by 41.1% and 37.9% during heating and cooling when the heat of fusion of PCM is 150 kJ/kg. - Highlights: → A new double layer phase change material floor is put forward. → The system is used to store heat or cold energy in the off-peak period and release them in the peak period during heating or cooling. → The optimal melting temperatures of PCMs in the system exist. → The heat and cold energy released by the floor with PCM in peak period can be increased by 41.1% and 37.9%.

  20. Effect of water content nitrogen gross mineralization and immobilization

    International Nuclear Information System (INIS)

    Videla C, Ximena; Parada, Ana Maria; Nario M, Adriana; Pino N, Ines; Hood, Rebeca

    2005-01-01

    The decomposition of organic matter in soil, and the accompanying mineralization and immobilization of inorganic N, are key processes in the soil plant cycle. It is hypothesized that moisture regime may also play an important role on these processes. Two laboratory studies were carried out to investigate the effect of moisture regime on gross mineralization and immobilization of N, in and Ultisol soil, which was incubated at 25 o C, under two moisture regimes, field capacity (CC) (40% w/w) and 85% of field capacity (34% w/w): Using mirror image 15 N isotope dilution techniques, it was possible to determine gross nitrification and mineralization rates. The rates of gross mineralization and nitrification rate in this soil was extremely rapid and efficient, specially with 85% CC. The N transformations varied with moisture regime (author)

  1. The one-dimensional Gross-Pitaevskii equation and its some excitation states

    Energy Technology Data Exchange (ETDEWEB)

    Prayitno, T. B., E-mail: trunk-002@yahoo.com [Physics Department, Faculty of Mathematics and Natural Science, Universitas Negeri Jakarta, Jl. Pemuda Rawamangun no. 10, Jakarta, 13220 (Indonesia)

    2015-04-16

    We have derived some excitation states of the one-dimensional Gross-Pitaevskii equation coupled by the gravitational potential. The methods that we have used here are taken by pursuing the recent work of Kivshar et. al. by considering the equation as a macroscopic quantum oscillator. To obtain the states, we have made the appropriate transformation to reduce the three-dimensional Gross-Pitaevskii equation into the one-dimensional Gross-Pitaevskii equation and applying the time-independent perturbation theory in the general solution of the one-dimensional Gross-Pitaevskii equation as a linear superposition of the normalized eigenfunctions of the Schrödinger equation for the harmonic oscillator potential. Moreover, we also impose the condition by assuming that some terms in the equation should be so small in order to preserve the use of the perturbation method.

  2. Pelvic Floor Physical Therapy for Vulvodynia: A Clinician's Guide.

    Science.gov (United States)

    Prendergast, Stephanie A

    2017-09-01

    Vulvar pain affects up to 20% of women at some point in their lives, and most women with vulvar pain have associated pelvic floor impairments. Pelvic floor dysfunction is associated with significant functional limitations in women by causing painful intercourse and urinary, bowel, and sexual dysfunction. A quick screening of the pelvic floor muscles can be performed in the gynecology office and should be used when patients report symptoms of pelvic pain. It is now known the vulvar pain syndromes are heterogeneous in origin; therefore, successful treatment plans are multimodal and include physical therapy. Copyright © 2017 Elsevier Inc. All rights reserved.

  3. DESIGN AND MANUFACTURING OF MODULAR PARQUET FLOORING IN INDUSTRIAL SYSTEM

    Directory of Open Access Journals (Sweden)

    Ivan CISMARU

    2014-09-01

    Full Text Available The paper submits constructive options and methods to design and manufacture modular parquet flooring, as well as fastening methods in constructions. Likewise, it presents the branches of civil engineering where modular parquet flooring may be turned to profit – industrial buildings, company premises or residential premises. The turn towards the achievement of private constructions, such as individual houses, led to losing control of the modular system applied in defining the inner sizes of the constructions and implicitly to the apparition of dimensional incompatibilities between the parquet flooring and the built spaces. The paper sets out (to solve by an individualized design procedure to achieve modular parquet flooring in industrial system, in correspondence with the sizes of the inner spaces afferent to the constructions.

  4. CAISSON TYPE HOLLOW FLOOR SLABS OF MONOLITHIC MULTI-STOREYED BUILDINGS

    OpenAIRE

    Malakhova Anna Nikolaevna

    2016-01-01

    One of the disadvantages of building structures made of reinforced concrete is their considerable weight. One of the trends to decrease the weight of concrete structures, including floor slabs, is the arrangement of voids in the cross-sectional building structures. In Russian and foreign practice paper, cardboard and plastic tubes has been used for creation of voids in the construction of monolithic floor slabs. Lightweight concretes were also used for production of precast hollow core floor ...

  5. Error Floor Analysis of Coded Slotted ALOHA over Packet Erasure Channels

    DEFF Research Database (Denmark)

    Ivanov, Mikhail; Graell i Amat, Alexandre; Brannstrom, F.

    2014-01-01

    We present a framework for the analysis of the error floor of coded slotted ALOHA (CSA) for finite frame lengths over the packet erasure channel. The error floor is caused by stopping sets in the corresponding bipartite graph, whose enumeration is, in general, not a trivial problem. We therefore ...... identify the most dominant stopping sets for the distributions of practical interest. The derived analytical expressions allow us to accurately predict the error floor at low to moderate channel loads and characterize the unequal error protection inherent in CSA.......We present a framework for the analysis of the error floor of coded slotted ALOHA (CSA) for finite frame lengths over the packet erasure channel. The error floor is caused by stopping sets in the corresponding bipartite graph, whose enumeration is, in general, not a trivial problem. We therefore...

  6. Touch Is Everywhere: Floor Surfaces as Ambient Haptic Interfaces.

    Science.gov (United States)

    Visell, Y; Law, A; Cooperstock, J R

    2009-01-01

    Floor surfaces are notable for the diverse roles that they play in our negotiation of everyday environments. Haptic communication via floor surfaces could enhance or enable many computer-supported activities that involve movement on foot. In this paper, we discuss potential applications of such interfaces in everyday environments and present a haptically augmented floor component through which several interaction methods are being evaluated. We describe two approaches to the design of structured vibrotactile signals for this device. The first is centered on a musical phrase metaphor, as employed in prior work on tactile display. The second is based upon the synthesis of rhythmic patterns of virtual physical impact transients. We report on an experiment in which participants were able to identify communication units that were constructed from these signals and displayed via a floor interface at well above chance levels. The results support the feasibility of tactile information display via such interfaces and provide further indications as to how to effectively design vibrotactile signals for them.

  7. Gross Motor Skills in Children With Idiopathic Clubfoot and the Association Between Gross Motor Skills, Foot Involvement, Gait, and Foot Motion.

    Science.gov (United States)

    Lööf, Elin; Andriesse, Hanneke; André, Marie; Böhm, Stephanie; Iversen, Maura D; Broström, Eva W

    2017-02-24

    Little is known regarding gross motor skills (GMS) in children with idiopathic clubfoot (IC). This study describes GMS, specifically foot involvement and asymmetries, and analyses the association between GMS, gait, and foot status in children with IC. Gross motor tasks and gait were analyzed in children with IC and typically developed (TD) children. GMS were assessed using videotapes and the Clubfoot Assessment Protocol (CAP). The Gait Deviation Index (GDI) and GDI-Kinetic were calculated from gait analyses. Children were divided into bilateral, unilateral clubfoot, or TD groups. To analyze asymmetries, feet within each group were further classified into superior or inferior foot, depending on their CAP scores. Correlations identified associations between CAP and GDI, GDI-Kinetic, passive foot motion, and Dimeglio Classification Scores at birth in the clubfeet. In total, 75 children (mean age, 5 years) were enrolled (bilateral n=22, unilateral clubfoot n=25, TD=28). Children with clubfeet demonstrated significantly lower GMS, gait, and foot motion compared with TD children. One leg standing and hopping deviated in 84% and 91%, respectively, in at least one foot in children with clubfoot. Gross motor asymmetries were evident in both children with bilateral and unilateral involvement. In children with unilateral clubfoot, contralateral feet showed few deviations in GMS compared with TD; however, differences existed in gait and foot motion. The association between GMS and gait, foot motion, and initial foot status varied between poor and moderate. Gross motor deficits and asymmetries are present in children with both bilateral and unilateral IC. Development of GMS of the contralateral foot mirrors that of TD children, but modifies to the clubfoot in gait and foot motion. The weak association with gait, foot motion, and initial clubfoot severity indicates that gross motor measurements represent a different outcome entity in clubfoot treatment. We therefore, recommend

  8. Floor cleaning: effect on bacteria and organic materials in hospital rooms.

    Science.gov (United States)

    Andersen, B M; Rasch, M; Kvist, J; Tollefsen, T; Lukkassen, R; Sandvik, L; Welo, A

    2009-01-01

    Routine surface cleaning is recommended to control the spread of pathogens in hospital environments. In Norway, ordinary cleaning of patient rooms is traditionally performed with soap and water. In this study, four floor-mopping methods--dry, spray, moist and wet mopping--were compared by two systems using adenosine triphosphate (ATP) bioluminescence (Hygiena and Biotrace). These systems assess residual organic soil on surfaces. The floor-mopping methods were also assessed by microbiological samples from the floor and air, before and after cleaning. All methods reduced organic material on the floors but wet and moist mopping seemed to be the most effective (P < 0.001, P < 0.011, respectively, ATP Hygiena). The two ATP methods were easy to use, although each had their own reading scales. Cleaning reduced organic material to 5-36% of the level present before cleaning, depending upon mopping method. All four mopping methods reduced bacteria on the floor from about 60-100 to 30-60 colony-forming units (cfu)/20cm2 floor. Wet, moist and dry mopping seemed to be more effective in reducing bacteria on the floor, than the spray mopping (P=0.007, P=0.002 and P=0.011, respectively). The burden of bacteria in air increased for all methods just after mopping. The overall best cleaning methods seemed to be moist and wet mopping.

  9. Gross Motor Skills and Cardiometabolic Risk in Children: A Mediation Analysis.

    Science.gov (United States)

    Burns, Ryan D; Brusseau, Timothy A; Fu, You; Hannon, James C

    2017-04-01

    The purpose of this study was to examine the linear relationship between gross motor skills and cardiometabolic risk, with aerobic fitness as a mediator variable, in low-income children from the United States. Participants were a convenience sample of 224 children (mean ± SD age = 9.1 ± 1.1 yr; 129 girls and 95 boys) recruited from five low-income elementary schools from the Mountain West Region of the United States. Gross motor skills were assessed using the Test for Gross Motor Development, 3rd Edition. Gross motor skills were analyzed using a locomotor skill, a ball skill, and a total gross motor skill score. Aerobic fitness was assessed using the Progressive Aerobic Cardiovascular Endurance Run that was administered during physical education class. A continuous and age- and sex-adjusted metabolic syndrome score (MetS) was calculated from health and blood marker measurements collected in a fasted state before school hours. Total effects, average direct effects, and indirect effects (average causal mediation effect) were calculated using a bootstrap mediation analysis method via a linear regression algorithm. The average causal mediation effect of gross locomotor skills on MetS scores, using aerobic fitness as the mediator variable, was statistically significant (β = -0.055, 95% confidence interval = -0.097 to -0.021, P = 0.003). The model explained approximately 17.5% of the total variance in MetS with approximately 43.7% of the relationship between locomotor skills and MetS mediated through aerobic fitness. Ball skills did not significantly relate with cardiometabolic risk. There is a significant relationship between gross locomotor skills and cardiometabolic risk that is partially mediated through aerobic fitness in a sample of low-income children from the United States.

  10. Vast Portfolio Selection with Gross-exposure Constraints().

    Science.gov (United States)

    Fan, Jianqing; Zhang, Jingjin; Yu, Ke

    2012-01-01

    We introduce the large portfolio selection using gross-exposure constraints. We show that with gross-exposure constraint the empirically selected optimal portfolios based on estimated covariance matrices have similar performance to the theoretical optimal ones and there is no error accumulation effect from estimation of vast covariance matrices. This gives theoretical justification to the empirical results in Jagannathan and Ma (2003). We also show that the no-short-sale portfolio can be improved by allowing some short positions. The applications to portfolio selection, tracking, and improvements are also addressed. The utility of our new approach is illustrated by simulation and empirical studies on the 100 Fama-French industrial portfolios and the 600 stocks randomly selected from Russell 3000.

  11. Robust Floor Determination Algorithm for Indoor Wireless Localization Systems under Reference Node Failure

    Directory of Open Access Journals (Sweden)

    Kriangkrai Maneerat

    2016-01-01

    Full Text Available One of the challenging problems for indoor wireless multifloor positioning systems is the presence of reference node (RN failures, which cause the values of received signal strength (RSS to be missed during the online positioning phase of the location fingerprinting technique. This leads to performance degradation in terms of floor accuracy, which in turn affects other localization procedures. This paper presents a robust floor determination algorithm called Robust Mean of Sum-RSS (RMoS, which can accurately determine the floor on which mobile objects are located and can work under either the fault-free scenario or the RN-failure scenarios. The proposed fault tolerance floor algorithm is based on the mean of the summation of the strongest RSSs obtained from the IEEE 802.15.4 Wireless Sensor Networks (WSNs during the online phase. The performance of the proposed algorithm is compared with those of different floor determination algorithms in literature. The experimental results show that the proposed robust floor determination algorithm outperformed the other floor algorithms and can achieve the highest percentage of floor determination accuracy in all scenarios tested. Specifically, the proposed algorithm can achieve greater than 95% correct floor determination under the scenario in which 40% of RNs failed.

  12. Gross Motor Profile and Its Association with Socialization Skills in Children with Autism Spectrum Disorders.

    Science.gov (United States)

    Pusponegoro, Hardiono D; Efar, Pustika; Soedjatmiko; Soebadi, Amanda; Firmansyah, Agus; Chen, Hui-Ju; Hung, Kun-Long

    2016-12-01

    While social impairment is considered to be the core deficit in children with autism spectrum disorder (ASD), a large proportion of these children have poor gross motor ability, and gross motor deficits may influence socialization skills in children with ASD. The objectives of this study were to compare gross motor skills in children with ASD to typically developing children, to describe gross motor problems in children with ASD, and to investigate associations between gross motor and socialization skills in children with ASD. This was a cross-sectional study including 40 ASD children aged from 18 months to 6 years and 40 age-matched typically developing controls. Gross motor and socialization skills were scored using the Vineland Adaptive Behavior Scales, 2 nd edition (Vineland-II). Below average gross motor function was found in eight of 40 (20%) ASD children. The mean gross motor v-scale score in the ASD group was 15.1 [standard deviation (SD) 3.12], significantly lower than in the control group [18.7, SD 2.09, p = 0.0001; 95% confidence intervals (CI) from -4.725 to -2.525]. The differences were most prominent in ball throwing and catching, using stairs, jumping, and bicycling. The ASD children with gross motor impairments had a mean socialization domain score of 66.6 (SD 6.50) compared to 85.7 (SD 10.90) in those without gross motor impairments (p = 0.0001, 95% CI from -25.327 to -12.736). Children with ASD had lower gross motor skills compared to typically developing children. Gross motor impairments were found in 20% of the ASD children, and these children also had lower socialization skills than those without gross motor impairments. Copyright © 2016. Published by Elsevier B.V.

  13. Clubfoot Does Not Impair Gross Motor Development in 5-Year-Olds.

    Science.gov (United States)

    Zapata, Karina A; Karol, Lori A; Jeans, Kelly A; Jo, Chan-Hee

    2018-04-01

    To evaluate the gross motor development of 5-year-olds using the Peabody Developmental Motor Scales, 2nd Edition (PDMS-2), test after initial nonoperative management of clubfoot as infants. The PDMS-2 Stationary, Locomotion, and Object Manipulation subtests were assessed on 128 children with idiopathic clubfeet at the age of 5 years. Children were categorized by their initial clubfoot severity as greater than 13, unilateral or bilateral involvement, and required surgery. Children with treated clubfeet had average gross motor scores (99 Gross Motor Quotient) compared with age-matched normative scores. Children with more severe clubfeet required surgery significantly more than children with less severe scores (P < .01). Peabody scores were not significantly different according to initial clubfoot severity, unilateral versus bilateral involvement, and surgical versus nonsurgical outcomes. Clubfoot does not significantly impair gross motor development in 5-year-olds.

  14. A Mobile Automated Characterization System (MACS) for indoor floor characterization

    International Nuclear Information System (INIS)

    Richardson, B.S.; Haley, D.C.; Dudar, A.M.; Ward, C.R.

    1995-01-01

    The Savannah River Technology Center (SRTC) and Oak Ridge National Laboratory are developing an advanced Mobile Automated Characterization System (MACS) to characterize indoor contaminated floors. MACS is based upon Semi-Intelligent Mobile Observing Navigator (SIMON), an earlier floor characterization system developed at SRTC. MACS will feature enhanced navigation systems, operator interface, and an interface to simplify integration of additional sensors. The enhanced navigation system will provide the capability to survey large open areas much more accurately than is now possible with SIMON, which is better suited for hallways and corridors that provide the means for recalibrating position and heading. MACS operator interface is designed to facilitate MACS's use as a tool for health physicists, thus eliminating the need for additional training in the robot's control language. Initial implementation of MACS will use radiation detectors. Additional sensors, such as PCB sensors currently being developed, will be integrated on MACS in the future. Initial use of MACS will be focused toward obtaining comparative results with manual methods. Surveys will be conducted both manually and with MACS to compare relative costs and data quality. While clear cost benefits anticipated, data quality benefits should be even more significant

  15. 17 CFR 155.2 - Trading standards for floor brokers.

    Science.gov (United States)

    2010-04-01

    ... 17 Commodity and Securities Exchanges 1 2010-04-01 2010-04-01 false Trading standards for floor brokers. 155.2 Section 155.2 Commodity and Securities Exchanges COMMODITY FUTURES TRADING COMMISSION TRADING STANDARDS § 155.2 Trading standards for floor brokers. Each contract market shall adopt and submit...

  16. Characterization of the protective capacity of flooring systems using force-deflection profiling.

    Science.gov (United States)

    Glinka, Michal N; Karakolis, Thomas; Callaghan, Jack P; Laing, Andrew C

    2013-01-01

    'Safety floors' aim to decrease the risk of fall-related injuries by absorbing impact energy during falls. Ironically, excessive floor deflection during walking or standing may increase fall risk. In this study we used a materials testing system to characterize the ability of a range of floors to absorb energy during simulated head and hip impacts while resisting deflection during simulated single-leg stance. We found that energy absorption for all safety floors (mean (SD)=14.8 (4.9)J) and bedside mats (25.1 (9.3)J) was 3.2- to 5.4-fold greater than the control condition (commercial carpet). While footfall deflections were not significantly different between safety floors (1.8 (0.7)mm) and the control carpet (3.7 (0.6)mm), they were significantly higher for two bedside mats. Finally, all of the safety floors, and two bedside mats, displayed 3-10 times the energy-absorption-to-deflection ratios observed for the baseline carpet. Overall, these results suggest that the safety floors we tested effectively addressed two competing demands required to reduce fall-related injury risk; namely the ability to absorb substantial impact energy without increasing footfall deflections. This study contributes to the literature suggesting that safety floors are a promising intervention for reducing fall-related injury risk in older adults. Copyright © 2012 IPEM. Published by Elsevier Ltd. All rights reserved.

  17. Floor response spectra of buildings with uncertain structural properties

    International Nuclear Information System (INIS)

    Chen, P.C.

    1975-01-01

    All Category I equipment, such as reactors, vessels, and major piping systems of nuclear power plants, is required to withstand earthquake loadings in order to minimize risk of seismic damage. The equipment is designed by using response spectra of the floor on which the equipment is mounted. The floor response spectra are constructed usually from the floor response time histories which are obtained through a deterministic dynamic analysis. This analysis assumes that all structural parameters, such as mass, stiffness, and damping have been calculated precisely, and that the earthquakes are known. However, structural parameters are usually difficult to determine precisely if the structures are massive and/or irregular, such as nuclear containments and its internal structures with foundation soil incorporated into the analysis. Faced with these uncertainties, it has been the practice to broaden the floor response spectra peaks by +-10 percent of the peak frequencies on the basis of conservatism. This approach is based on engineering judgement and does not have an analytical basis to provide a sufficient level of confidence in using these spectra for equipment design. To insure reliable design, it is necessary to know structural response variations due to variations in structural properties. This consideration leads to the treatment of structural properties as random variables and the use of probabilistic methods to predict structural response more accurately. New results on floor response spectra of buildings with uncertain structural properties obtained by determining the probabilistic dynamic response from the deterministic dynamic response and its standard deviation are presented. The resulting probabilistic floor response spectra are compared with those obtained deterministically, and are shown to provide a more reliable method for determining seismic forces

  18. Integrability of the Gross-Pitaevskii equation with Feshbach resonance management

    International Nuclear Information System (INIS)

    Zhao Dun; Luo Honggang; Chai Huayue

    2008-01-01

    In this Letter we study the integrability of a class of Gross-Pitaevskii equations managed by Feshbach resonance in an expulsive parabolic external potential. By using WTC test, we find a condition under which the Gross-Pitaevskii equation is completely integrable. Under the present model, this integrability condition is completely consistent with that proposed by Serkin, Hasegawa, and Belyaeva [V.N. Serkin, A. Hasegawa, T.L. Belyaeva, Phys. Rev. Lett. 98 (2007) 074102]. Furthermore, this integrability can also be explicitly shown by a transformation, which can convert the Gross-Pitaevskii equation into the well-known standard nonlinear Schroedinger equation. By this transformation, each exact solution of the standard nonlinear Schroedinger equation can be converted into that of the Gross-Pitaevskii equation, which builds a systematical connection between the canonical solitons and the so-called nonautonomous ones. The finding of this transformation has a significant contribution to understanding the essential properties of the nonautonomous solitons and the dynamics of the Bose-Einstein condensates by using the Feshbach resonance technique

  19. School Physical Activity Programming and Gross Motor Skills in Children.

    Science.gov (United States)

    Burns, Ryan D; Fu, You; Hannon, James C; Brusseau, Timothy A

    2017-09-01

    We examined the effect of a comprehensive school physical activity program (CSPAP) on gross motor skills in children. Participants were 959 children (1st-6th grade; Mean age = 9.1 ± 1.5 years; 406 girls, 553 boys) recruited from 5 low-income schools receiving a year-long CSPAP intervention. Data were collected at the beginning of the school year and at a 36-week follow-up. Gross motor skills were assessed using the Test for Gross Motor Development (3rd ed.) (TGMD-3) instrument. Multi-level mixed effects models were employed to examine the effect of CSPAP on TGMD-3 scores, testing age and sex as effect modifiers and adjusting for clustering of observations within the data structure. There were statistically significant coefficients for time (β = 8.1, 95% CI [3.9, 12.3], p skills and ball skills sub-test scores. Children showed improved gross motor skill scores at the end of the 36-week CSPAP that were modified by age, as younger children displayed greater improvements in TGMD-3 scores compared to older children.

  20. Development of a 3-dimensional seismic isolation floor for computer systems

    International Nuclear Information System (INIS)

    Kurihara, M.; Shigeta, M.; Nino, T.; Matsuki, T.

    1991-01-01

    In this paper, we investigated the applicability of a seismic isolation floor as a method for protecting computer systems from strong earthquakes, such as computer systems in nuclear power plants. Assuming that the computer system is guaranteed for 250 cm/s 2 of input acceleration in the horizontal and vertical directions as the seismic performance, the basic design specification of the seismic isolation floor is considered as follows. Against S 1 level earthquakes, the maximum acceleration response of the seismic isolation floor in the horizontal and vertical directions is kept less than 250 cm/s 2 to maintain continuous computer operation. Against S 2 level earthquakes, the isolation floor allows large horizontal movement and large displacement of the isolation devices to reduce the acceleration response, although it is not guaranteed to be less than 250 cm/s 2 . By reducing the acceleration response, however, serious damage to the computer systems is reduced, so that they can be restarted after an earthquake. Usually, seismic isolation floor systems permit 2-dimensional (horizontal) isolation. However, in the case of just-under-seated earthquakes, which have large vertical components, the vertical acceleration response of this system is amplified by the lateral vibration of the frame of the isolation floor. Therefore, in this study a 3-dimensional seismic isolation floor, including vertical isolation, was developed. This paper describes 1) the experimental results of the response characteristics of the 3-dimensional seismic isolation floor built as a trial using a 3-dimensional shaking table, and 2) comparison of a 2-dimensional analytical model, for motion in one horizontal direction and the vertical direction, to experimental results. (J.P.N.)

  1. Floor heating and cooling combined with displacement ventilation: Possibilities and limitations

    Energy Technology Data Exchange (ETDEWEB)

    Causone, Francesco; Corgnati, Stefano P. [TEBE Research Group, Department of Energetics, Politecnico di Torino, Corso Duca degli Abruzzi 24, 10129 Torino (Italy); Baldin, Fabio [Department of Applied Physics, University of Padova, via Venezia 1, 35131 Padova (Italy); Olesen, Bjarne W. [ICIEE, Department of Civil Engineering, Technical University of Denmark, Nils Koppels Alle Building 402, 2800 Kgs. Lyngby (Denmark)

    2010-12-15

    Design guidelines envisage that floor heating can be used together with displacement ventilation (DV), provided that the supply air is not overly heated before it can reach heat and contaminant sources. If this is not controlled a mixing flow pattern could occur in the room. The use of floor cooling with DV is also considered possible, although draught risk at ankle level and vertical air temperature differences must be controlled carefully, because they could increase. Few studies on these topics were found in the literature. An indoor environmental chamber was set up to obtain measurements aimed at analysing the possibilities and limitations of combining floor heating/cooling with DV. Air temperature profiles, air velocity profiles, surface temperatures and ventilation effectiveness were measured under different environmental conditions that may occur in practice. These values were compared to equivalent temperature measurements obtained using a thermal manikin. The measurements show that floor heating can be used with DV, obtaining high ventilation effectiveness values. A correlation between the floor heating capacity and the air temperature profile in the room was found. Measurements showed that floor cooling does not increase draught risk at ankle level, although it does increase vertical air temperature differences. (author)

  2. Pyroclastic Deposits in the Floor-fractured Crater Alphonsus

    Science.gov (United States)

    Allen, Carlton C.; Donaldson-Hanna, Kerri L.; Pieters, Carle M.; Moriarty, Daniel P.; Greenhagen, Benjamin T.; Bennett, Kristen A.; Kramer, Georgiana Y.; Paige, David A.

    2013-01-01

    Alphonsus, the 118 km diameter floor-fractured crater, is located immediately east of Mare Nubium. Eleven pyroclastic deposits have been identified on the crater's floor. Early telescopic spectra suggest that the floor of Alphonsus is noritic, and that the pyroclastic deposits contain mixtures of floor material and a juvenile component including basaltic glass. Head and Wilson contend that Nubium lavas intruded the breccia zone beneath Alphonsus, forming dikes and fractures on the crater floor. In this model, the magma ascended to the level of the mare but cooled underground, and a portion broke thru to the surface in vulcanian (explosive) eruptions. Alternatively, the erupted material could be from a source unrelated to the mare, in the style of regional pyroclastic deposits. High-resolution images and spectroscopy from the Moon Mineralogy Mapper (M3), Diviner Lunar Radiometer, and Lunar Reconnaissance Orbiter Camera Narrow Angle Camera (NAC) provide data to test these formation models. Spectra from M3 confirm that the crater floor is primarily composed of noritic material, and that the Nubium lavas are basaltic. Spectra from the three largest pyroclastic deposits in Alphonsus are consistent with a minor low- Ca pyroxene component in a glass-rich matrix. The centers of the 2 micron absorption bands have wavelengths too short to be of the same origin as the Nubium basalts. Diviner Christiansen feature (CF) values were used to estimate FeO abundances for the crater floor, Nubium soil, and pyroclastic deposits. The estimated abundance for the crater floor (7.5 +/- 1.4 wt.%) is within the range of FeO values for Apollo norite samples. However, the estimated FeO abundance for Nubium soil (13.4 +/- 1.4 wt.%) is lower than those measured in most mare samples. The difference may reflect contamination of the mare soil by highland ejecta. The Diviner-derived FeO abundance for the western pyroclastic deposit is 13.8 +/- 3.3 wt.%. This is lower than the values for mare soil

  3. Resident’s Floor Level Preference in High-Rise Residential Buildings in China:A Case Study of Shijiazhuang City,Hebei Province

    Institute of Scientific and Technical Information of China (English)

    Sun; Pingjun; Wang; Ying; Pang; Ruiqiu; Song; Xinyan

    2016-01-01

    With the constant advance of global urbanization and aggravation of urban construction land scarcity,high-rise residential buildings have become one of the main carriers of urban residential function on account of both land saving and large housing requirement.However,relevant studies on consumers’ floor selection preference in high-rise residential buildings,regarding what inherent and regular features and causes it has,are still insufficient,despite that related issues have important practical significance for real estate developers and designers’ decision making in terms of dwelling size ratio,floor area,indoor layout,and so on.This study,based on systematic examination of existing domestic and international researches,seeks to make empirical tests and generalization on the above issues from the aspect of "utility function"(safety,comfortableness,accessibility and economic efficiency) of the living environment that impacted by different floor levels,and floor selection features regarding consumers’ social and family structure attributes,as well as the intrinsic correlation between them.The results show the existence of floor level preference in high-rise residential buildings.Its essence is a personalized characterization of consumers’ social and family structures’ attributes in selecting the "utility function" of the living environment,as the preference value differs under various attributes including gender,age,income,family members and others.

  4. 46 CFR 167.01-8 - Inspection of school ships using gross tonnage criterion.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 7 2010-10-01 2010-10-01 false Inspection of school ships using gross tonnage criterion... SCHOOLS PUBLIC NAUTICAL SCHOOL SHIPS General Provisions § 167.01-8 Inspection of school ships using gross... school ships by relative sizes in gross tonnages. When it is determined in accordance with § 70.05-20 of...

  5. Gross and microscopic lesions in corals from Micronesia

    Science.gov (United States)

    Work, Thierry M.; Aeby, Greta S.; Hughen, Konrad A.

    2015-01-01

    The authors documented gross and microscopic morphology of lesions in corals on 7 islands spanning western, southern, and eastern Micronesia, sampling 76 colonies comprising 30 species of corals among 18 genera, with Acropora, Porites, and Montipora dominating. Tissue loss comprised the majority of gross lesions sampled (41%), followed by discoloration (30%) and growth anomaly (29%). Of 31 cases of tissue loss, most lesions were subacute (48%), followed by acute and chronic (26% each). Of 23 samples with discoloration, most were dark discoloration (40%), with bleaching and other discoloration each constituting 30%. Of 22 growth anomalies, umbonate growth anomalies composed half, with exophytic, nodular, and rugose growth anomalies composing the remainder. On histopathology, for 9 cases of dark discoloration, fungal infections predominated (77%); for 7 bleached corals, depletion of zooxanthellae from the gastrodermis made up a majority of microscopic diagnoses (57%); and for growth anomalies other than umbonate, hyperplasia of the basal body wall was the most common microscopic finding (63%). For the remainder of the gross lesions, no single microscopic finding constituted >50% of the total. Host response varied with the agent present on histology. Fragmentation of tissues was most often associated with algae (60%), whereas necrosis dominated (53%) for fungi. Two newly documented potentially symbiotic tissue-associated metazoans were seen in Porites and Montipora. Findings of multiple potential etiologies for a given gross lesion highlight the importance of incorporating histopathology in coral disease surveys. This study also expands the range of corals infected with cell-associated microbial aggregates.

  6. Using Six Sigma methodology to reduce patient transfer times from floor to critical-care beds.

    Science.gov (United States)

    Silich, Stephan J; Wetz, Robert V; Riebling, Nancy; Coleman, Christine; Khoueiry, Georges; Abi Rafeh, Nidal; Bagon, Emma; Szerszen, Anita

    2012-01-01

    In response to concerns regarding delays in transferring critically ill patients to intensive care units (ICU), a quality improvement project, using the Six Sigma process, was undertaken to correct issues leading to transfer delay. To test the efficacy of a Six Sigma intervention to reduce transfer time and establish a patient transfer process that would effectively enhance communication between hospital caregivers and improve the continuum of care for patients. The project was conducted at a 714-bed tertiary care hospital in Staten Island, New York. A Six Sigma multidisciplinary team was assembled to assess areas that needed improvement, manage the intervention, and analyze the results. The Six Sigma process identified eight key steps in the transfer of patients from general medical floors to critical care areas. Preintervention data and a root-cause analysis helped to establish the goal transfer-time limits of 3 h for any individual transfer and 90 min for the average of all transfers. The Six Sigma approach is a problem-solving methodology that resulted in almost a 60% reduction in patient transfer time from a general medical floor to a critical care area. The Six Sigma process is a feasible method for implementing healthcare related quality of care projects, especially those that are complex. © 2011 National Association for Healthcare Quality.

  7. Gross Motor Profile and Its Association with Socialization Skills in Children with Autism Spectrum Disorders

    OpenAIRE

    Hardiono D. Pusponegoro; Pustika Efar; Soedjatmiko; Amanda Soebadi; Agus Firmansyah; Hui-Ju Chen; Kun-Long Hung

    2016-01-01

    While social impairment is considered to be the core deficit in children with autism spectrum disorder (ASD), a large proportion of these children have poor gross motor ability, and gross motor deficits may influence socialization skills in children with ASD. The objectives of this study were to compare gross motor skills in children with ASD to typically developing children, to describe gross motor problems in children with ASD, and to investigate associations between gross motor and sociali...

  8. Radioactivity in the groundwater of a high background radiation area.

    Science.gov (United States)

    Shabana, E I; Kinsara, A A

    2014-11-01

    Natural radioactivity was measured in groundwater samples collected from 37 wells scattered in an inhabited area of high natural background radiation, in a purpose of radiation protection. The study area is adjacent to Aja heights of granitic composition in Hail province, Saudi Arabia. Initial screening for gross α and gross β activities showed levels exceeded the national regulation limits set out for gross α and gross β activities in drinking water. The gross α activity ranged from 0.17 to 5.41 Bq L(-)(1) with an average value of 2.15 Bq L(-)(1), whereas gross β activity ranged from 0.48 to 5.16 Bq L(-)(1), with an average value of 2.60 Bq L(-)(1). The detail analyses indicated that the groundwater of this province is contaminated with uranium and radium ((226)Ra and (228)Ra). The average activity concentrations of (238)U, (234)U, (226)Ra and (228)Ra were 0.40, 0.77, 0.29 and 0.46 Bq L(-)(1), respectively. The higher uranium content was found in the samples of granitic aquifers, whereas the higher radium content was found in the samples of sandstone aquifers. Based on the obtained results, mechanism of leaching of the predominant radionuclides has been discussed in detail. Copyright © 2014 Elsevier Ltd. All rights reserved.

  9. Regular exercisers have stronger pelvic floor muscles than nonregular exercisers at midpregnancy.

    Science.gov (United States)

    Bø, Kari; Ellstrøm Engh, Marie; Hilde, Gunvor

    2018-04-01

    Today all healthy pregnant women are encouraged to be physically active throughout pregnancy, with recommendations to participate in at least 30 minutes of aerobic activity on most days of the week in addition to performing strength training of the major muscle groups 2-3 days per week and also pelvic floor muscle training. There is, however, an ongoing debate whether general physical activity enhances or declines pelvic floor muscle function. The objectives of the study were to compare vaginal resting pressure, pelvic floor muscle strength, and endurance in regular exercisers (exercise ≥30 minutes 3 or more times per week) and nonexercisers at midpregnancy. Furthermore, another objective was to assess whether regular general exercise or pelvic floor muscle strength was associated with urinary incontinence. This was a cross-sectional study at mean gestational week 20.9 (±1.4) including 218 nulliparous pregnant women, with a mean age of 28.6 years (range, 19-40 years) and prepregnancy body mass index of 23.9 kg/m 2 (SD, 4.0). Vaginal resting pressure, pelvic floor muscle strength, and pelvic floor muscle endurance were measured by a high-precision pressure transducer connected to a vaginal balloon. The International Consultation on Incontinence Questionnaire Urinary Incontinence Short Form was used to assess urinary incontinence. Differences between groups were analyzed using an independent-sample Student t test. Linear regression analysis was conducted to adjust for prepregnancy body mass index, age, smoking during pregnancy, and regular pelvic floor muscle training during pregnancy. The significance value was set to P ≤ .05. Regular exercisers had statistically significant stronger (mean 6.4 cm H 2 O [95% confidence interval, 1.7-11.2]) and more enduring (mean 39.9 cm H 2 Osec [95% confidence interval, 42.2-75.7]) pelvic floor muscles. Only pelvic floor muscle strength remained statistically significant, when adjusting for possible confounders. Pelvic floor

  10. Vast Portfolio Selection with Gross-exposure Constraints*

    Science.gov (United States)

    Fan, Jianqing; Zhang, Jingjin; Yu, Ke

    2012-01-01

    We introduce the large portfolio selection using gross-exposure constraints. We show that with gross-exposure constraint the empirically selected optimal portfolios based on estimated covariance matrices have similar performance to the theoretical optimal ones and there is no error accumulation effect from estimation of vast covariance matrices. This gives theoretical justification to the empirical results in Jagannathan and Ma (2003). We also show that the no-short-sale portfolio can be improved by allowing some short positions. The applications to portfolio selection, tracking, and improvements are also addressed. The utility of our new approach is illustrated by simulation and empirical studies on the 100 Fama-French industrial portfolios and the 600 stocks randomly selected from Russell 3000. PMID:23293404

  11. Generation of airborne Listeria innocua from model floor drains.

    Science.gov (United States)

    Berrang, Mark E; Frank, Joseph F

    2012-07-01

    Listeria monocytogenes can colonize floor drains in poultry processing and further processing facilities, remaining present even after cleaning and disinfection. Therefore, during wash down, workers exercise caution to avoid spraying hoses directly into drains in an effort to prevent the escape and transfer of drain microflora to food contact surfaces. The objective of this study was to examine the extent to which an inadvertent water spray into a colonized floor drain can cause the spread of airborne Listeria. Listeria innocua was used to inoculate a polyvinyl chloride model floor drain, resulting in approximately 10(8) cells per ml of phosphate-buffered saline and 10(4) attached cells per square centimeter of inner surface. Each model drain was subjected to a 2-s spray of tap water at 68.9 kPa from a distance of 1 m. Drains were sprayed while filled and again after emptying. Airborne cells were collected by using sedimentation plates containing Listeria selective agar which were placed on the floor and walls of a contained room at incremental horizontal and vertical distances of 0.6, 1.2, 2.4, or 4.0 m from the drain. Sedimentation plates were exposed for 10 min. A mechanical sampler was used to also collect air by impaction on the surface of Listeria selective agar to determine the number of cells per liter of air. The experiment was conducted in triplicate rooms for each of four replications. L. innocua was detected on sedimentation plates on the floor as far as 4.0 m from the drain and on walls as high as 2.4 m above the floor and 4 m from the drain. A 2-s spray with a water hose into a contaminated drain can cause airborne spread of Listeria, resulting in the potential for cross-contamination of food contact surfaces, equipment, and exposed product.

  12. Sinus Floor Elevation and Augmentation Using Synthetic Nanocrystalline and Nanoporous Hydroxyapatite Bone Substitute Materials: Preliminary Histologic Results.

    Science.gov (United States)

    Belouka, Sofia-Maria; Strietzel, Frank Peter

    To compare the tissue composition of augmented sites after using two different synthetic bone substitute materials, nanocrystalline and nanoporous hydroxyapatite (HA), for sinus floor elevation and augmentation. Forty-four patients received 88 titanium screw implants (Camlog Promote plus) of 4.3-mm diameter and 11- or 13-mm length, placed simultaneously during sinus floor elevation and augmentation. Nanocrystalline (Ostim) or nanoporous (NanoBone) HA were used exclusively. Bone substitute materials and implant lengths were allocated by randomization. Bone biopsy specimens were obtained from the former area of the lateral access window at implant exposure during healing abutment placement after 6 months. Biopsy specimens were prepared and examined histologically and histomorphometrically. All implants were osseointegrated at the time of exposure. Clinically and histologically, no signs of inflammation in the augmented sites were present. The histomorphometric analysis of 44 biopsy specimens revealed 31.8% ± 11.6% newly formed bone for sites augmented with nanocrystalline HA and 34.6% ± 9.2% for nanoporous HA (P = .467). The proportion of remaining bone substitute material was 28.4% ± 18.6% and 30% ± 13%, respectively (P = .453). The proportion of soft tissue within the biopsy specimens was 39.9% ± 11.1% and 35.4% ± 6.8%, respectively (P = .064). No significant differences were found between the area fractions of bone, bone substitute material, and soft tissue concerning the bone substitute material utilized. Within the present study, both synthetic bone substitute materials, nanocrystalline and nanoporous HA, were found to support bone formation in sinus floor elevation and augmentation procedures by osteoconductivity. They were not completely resorbed after 6 months. The amounts of newly formed bone, soft tissue, and bone substitute material remnants were found to be similar, indicating that both materials are likewise suitable for sinus floor elevation and

  13. Clinical functional evaluation of female's pelvic floor: integrative review

    Directory of Open Access Journals (Sweden)

    Ana Carolina Nociti Lopes Fernandes

    2018-06-01

    Full Text Available Abstract Introduction: The effectiveness of pelvic floor muscle training (PFMT depends on the correct prescription of intensity, repetition and endurance of muscle contractions, which are provided by an adequate assessment of pelvic floor muscle. Objective: Verify the techniques, resources and strategies used for clinical functional evaluation of female pelvic floor (PF described in literature. Methods: It’s an integrative review of published studies and books from 2010 until December 2015. Relevant articles with complete description of PF evaluation were found through the use of Scielo, LILACS, PubMed and Medline databases. Results: 34 articles that fulfilled all the criteria were selected. Conclusion: The most used techniques, resources and strategies were: anamnesis, physical examination, measurement of pelvic floor muscle activity using Modified Oxford Scale or perineometry, and use of questionnaires to analyze patient's perspective of their own symptoms. Thus, we could use the parameters obtained in the evaluation to plan an ideal PFMT for each patient, so the physiotherapist would have a good database to analyze the evolution and define the end of therapy.

  14. Physical, Complementary, and Alternative Medicine in the Treatment of Pelvic Floor Disorders.

    Science.gov (United States)

    Arnouk, Alex; De, Elise; Rehfuss, Alexandra; Cappadocia, Carin; Dickson, Samantha; Lian, Fei

    2017-06-01

    The purpose of the study was to catalog the most recent available literature regarding the use of conservative measures in treatment of pelvic floor disorders. Pelvic floor disorders encompass abnormalities of urination, defecation, sexual function, pelvic organ prolapse, and chronic pain, and can have significant quality of life implications for patients. Current guidelines recommend behavioral modifications and conservative treatments as first-line therapy for pelvic floor disorders. We have reviewed the literature for articles published on physical, complementary, and alternative treatments for pelvic floor disorders over the past 5 years. Review of pelvic floor muscle physiotherapy (PFMT) and biofeedback (BF) shows a benefit for patients suffering from bladder dysfunction (incontinence, overactive bladder), bowel dysfunction (constipation, fecal incontinence), pelvic organ prolapse, and sexual dysfunction (pelvic pain). Combination of PFMT and BF has shown improved results compared to PFMT alone, and some studies find that electrical stimulation can augment the benefit of BF and PFMT. Additionally, acupuncture and cognitive behavioral therapy has shown to be an effective treatment for pelvic floor disorders, particularly with respect to pelvic pain. This update highlights beneficial conservative treatments available for pelvic floor dysfunction, and supplements the current literature on treatment options for patients suffering from these disorders.

  15. Apparatus for treating the walls and floor of the pelvic cavity with radiation

    International Nuclear Information System (INIS)

    Clayton, R.S.

    1975-01-01

    An apparatus for reaing carcinoma of the walls and floor of the pelvic cavity is described. An elongated tube has an inner end adapted to be placed in the pelvic cavity and an outer end adapted to extend through to the outside of the body. Radioactive material is placed at the inner end. An inner balloon above the radioactive material is inflated to hold a body of liquid shielding material such as mercury. A lower balloon portion beneath the inner balloon spaces areas to be treated such as the walls and floor of the pelvic cavity from the radioactive material. An upper balloon portion above the inner balloon keeps the intestines out of the pelvic cavity and away from the radioactive material. The apparatus is inserted into the pelvic cavity through an abdominal incision. When treating a woman for carcinoma in the walls and floor of the pelvic cavity the tube is moved through the vaginal passage from the inside outwardly. When treating a woman with a closed vaginal passage, as may result from surgery, or when treating a man, such as for carcinoma of the bladder, the tube will pass out of the body through a lower abdominal incision. Following treatment, all balloons are deflated so that the apparatus can be withdrawn through the vaginal passage or the lower abdominal incision, as the case may be. (auth)

  16. Floor-Fractured Craters on Ceres and Implications for Internal Composition and Processes

    Science.gov (United States)

    Buczkowski, D.; Schenk, P.; Scully, J. E. C.; Park, R. S.; Preusker, F.; Raymond, C. A.; Russell, C. T.

    2016-12-01

    Several of the impact craters on Ceres have patterns of fractures on their floors. These fractures appear similar to those found within a class of lunar craters referred to as Floor-Fractured Craters (FFCs) [1]. Lunar FFCs are characterized by anomalously shallow floors cut by radial, concentric, and/or polygonal fractures, and have been classified into crater classes, Types 1 through 6, based on their morphometric properties [1,2]. Models for their formation have included both floor uplift due to magmatic intrusion below the crater or floor shallowing due to viscous relaxation. However, the observation that the depth versus diameter (d/D) relationship of the FFCs is distinctly shallower than the same association for other lunar craters supports the hypotheses that the floor fractures form due to shallow magmatic intrusion under the crater [2]. We have cataloged the Ceres FFCs according to the classification scheme designed for the Moon. Large (>50 km) Ceres FFCs are most consistent with Type 1 lunar FFCs, having deep floors, central peaks, wall terraces, and radial and/or concentric fractures. Smaller craters on Ceres are more consistent with Type 4 lunar FFCs, having less-pronounced floor fractures and v-shaped moats separating the wall scarp from the crater interior. An analysis of the d/D ratio for Ceres craters shows that, like lunar FFCs, the Ceres FFCs are anomalously shallow. This suggests that the fractures on the floor of Ceres FFCs may be due the intrusion of a low-density material below the craters that is uplifting their floors. While on the Moon the intrusive material is hypothesized to be silicate magma, this is unlikely for Ceres. However, a cryovolcanic extrusive edifice has been identified on Ceres [3], suggesting that cryomagmatic intrusions could be responsible for the formation of the Ceres FFCs. References: [1] Schultz P. (1976) Moon, 15, 241-273 [2] Jozwiak L.M. et al (2015) JGR 117, doi: 10.1029/2012JE004134 [3] Ruesch O. et al (2016

  17. Assessment of pelvic floor dysfunctions using dynamic magnetic resonance imaging

    Directory of Open Access Journals (Sweden)

    Hoda Salah Darwish

    2014-03-01

    Conclusion: Dynamic MRI is an ideal, non invasive technique which does not require patient preparation for evaluation of pelvic floor. It acts as one stop shop for diagnosing single or multiple pelvic compartment involvement in patients with pelvic floor dysfunction.

  18. Pelvic floor functional disorders in vaginally delivered primiparae

    OpenAIRE

    Antolic, Andrea

    2011-01-01

    In this study we examined pelvic floor functional disorders in primiparae with single pregnancies, cephalic presentation at term at the Charité delivery department before and during pregnancy as well as after vaginal delivery by means of questionnaire in relation to maternal, neonatal and obstetric risk factors. The pathophysiology of pelvic floor disorders is still not statisfyingly resolved. During pregnancy 74% of primiparae knew about the interrelation between delivery and sexual disorde...

  19. Chemical hazards analysis of resilient flooring for healthcare.

    Science.gov (United States)

    Lent, Tom; Silas, Julie; Vallette, Jim

    2010-01-01

    This article addresses resilient flooring, evaluating the potential health effects of vinyl flooring and the leading alternatives-synthetic rubber, polyolefin, and linoleum-currently used in the healthcare marketplace. The study inventories chemicals incorporated as components of each of the four material types or involved in their life cycle as feedstocks, intermediary chemicals, or emissions. It then characterizes those chemicals using a chemical hazard-based framework that addresses persistence and bioaccumulation, human toxicity, and human exposures.

  20. Quality of life in women with pelvic floor dysfunction

    Directory of Open Access Journals (Sweden)

    Mladenović-Segedi Ljiljana

    2011-01-01

    Full Text Available Background/Aim. Pelvic floor dysfunction is a frequent problem affecting more than 50% of women in peri- and postmenopause. Considering that ageing and menopause befall in the significant factors causing this issue, as well as the expected longevity of women in the world and in our country, pelvic floor dysfunction prevelence is foreseen to be even higher. The aim of the study was to evaluate impact of the symptoms of pelvic dysfunction on quality of life and examine body image satisfaction in adult women with pelvic organ prolapse presenting to tertiary care clinic for surgical treatment. Methods. This prospective case-control study included 50 patients who presented to tertiary care gynecology clinic for surgical treatment and 50 controls with normal pelvic floor support and without urinary incontinence who presented tertiary care gynecology clinic for other reasons. Both, patients and controls, completed two quastionnaires recommended for the evaluation of symptoms (Pelvic floor distress inventory - short forms and quality of life impact (Pelvic floor impact questionnaire - short form of pelvic organ prolapse, and Body Image Scale. Results. The patients scored significantly worse on the prolapse, urinary, colorectal scales and overall score of Pelvic floor distress inventory - 20 than controls subjects (134.91 vs 78.08; p < 0.01. The patients also measured significant decrease in condition- specific quality of life (89.23 vs 3.1; p < 0.01. They were more likely to feel self-conscious (78% vs 42%; p < 0.01, less likely to feel physically attractive (78% vs 22%; p < 0.01, more likely to have difficulty looking at themselves naked (70% vs 42%; p < 0.01, less likely to feel sexually attractive (64% vs 32%; p < 0.01, and less likely to feel feminine (56% vs 16%; p < 0.05, than controls. There were no differencies in their feeling of dissatisfaction with appearance when dressed, avoiding people because of appereance and overall dissatisfaction with

  1. Amiata donkeys: fat globule characteristics, milk gross composition and fatty acids

    Directory of Open Access Journals (Sweden)

    Mina Martini

    2014-02-01

    Full Text Available Amiata donkeys are a native breed reared in central Italy. Safeguarding native donkey breeds represents an opportunity for the development of marginal areas, especially given that donkey milk is now appearing on the market due to its potential benefits for human health. To date, only a few studies have focused on the characteristics of the milk fat globules (MFGs in the donkey species. The aim of this study was to assess the morphometric characteristics of the fat globules, gross composition and fatty acid classes in milk from Amiata donkeys reared according to the typical farming and feeding systems of the area of origin. Individual milk samples, collected from 28 Amiata donkeys between 90 and 150 days of lactation, showed the following average composition (g/100 mL: 9.47 dry matter, 1.63 protein, 0.78 casein, 0.53 fat, 7.12 lactose, and 0.36 ash. The unsaturated:saturated fatty acids ratio in milk was close to 1. The percentage of short chains was 12.29, and the percentage of long chain fatty acids was 47.64. The donkey MFGs showed an average diameter of 1.92 μm, and a number of 2.18*109/mL. Regarding MFG distribution, 70% of the globules donkey of milk are smaller than 2 μm. In conclusion, the gross composition and fatty acids of Amiata donkey milk showed similarities with milk from other Italian donkey breeds, with the exception of the monounsaturated fatty acid values which were slightly higher. Donkey MFGs had a smaller diameter and were fewer than in the ruminant species.

  2. Modelling the cost-effectiveness of impact-absorbing flooring in Swedish residential care facilities.

    Science.gov (United States)

    Ryen, Linda; Svensson, Mikael

    2016-06-01

    Fall-related injuries among the elderly, specifically hip fractures, cause significant morbidity and mortality as well as imposing a substantial financial cost on the health care system. Impact-absorbing flooring has been advocated as an effective method for preventing hip fractures resulting from falls. This study identifies the cost-effectiveness of impact-absorbing flooring compared to standard flooring in residential care facilities for the elderly in a Swedish setting. An incremental cost-effectiveness analysis was performed comparing impact-absorbing flooring to standard flooring using a Markov decision model. A societal perspective was adopted and incremental costs were compared to incremental gains in quality-adjusted life years (QALYs). Data on costs, probability transitions and health-related quality of life measures were retrieved from the published literature and from Swedish register data. Probabilistic sensitivity analysis was performed through a Monte Carlo simulation. The base-case analysis indicates that the impact-absorbing flooring reduces costs and increases QALYs. When allowing for uncertainty we find that 60% of the simulations indicate that impact-absorbing flooring is cost-saving compared to standard flooring and an additional 20% that it has a cost per QALY below a commonly used threshold value : Using a modelling approach, we find that impact-absorbing flooring is a dominant strategy at the societal level considering that it can save resources and improve health in a vulnerable population. © The Author 2015. Published by Oxford University Press on behalf of the European Public Health Association. All rights reserved.

  3. Gross alpha/beta analyses in water by liquid scintillation counting

    International Nuclear Information System (INIS)

    Wong, C.T.; Lawrence Livermore National Laboratory, CA; Soliman, V.M.; Perera, S.K.

    2005-01-01

    The standard procedure for analyzing gross alpha and gross beta in water is evaporation of the sample and radioactivity determination of the resultant solids by proportional counting. This technique lacks precision, and lacks sensitivity for samples with high total dissolved solids. Additionally, the analytical results are dependent on the choice of radionuclide calibration standard and the sample matrix. Direct analysis by liquid scintillation counting has the advantages of high counting efficiencies and minimal sample preparation time. However, due to the small sample aliquants used for analysis, long count times are necessary to reach required detection limits. The procedure proposed consists of evaporating a sample aliquant to dryness, dissolving the resultant solids in a small volume of dilute acid, followed by liquid scintillation counting to determine radioactivity. This procedure can handle sample aliquants containing up to 500 mg of dissolved solids. Various acids, scintillation cocktail mixtures, instrument discriminator settings, and regions of interest (ROI) were evaluated to determine optimum counting conditions. Precision is improved and matrix effects are reduced as compared to proportional counting. Tests indicate that this is a viable alternative to proportional counting for gross alpha and gross beta analyses of water samples. (author)

  4. 26 CFR 1.132-3T - Qualified employee discount-1985 through 1988 (temporary).

    Science.gov (United States)

    2010-04-01

    ... appropriate industry average. (iv) Redetermination of gross profit percentage. If substantial changes in an... store is a cosmetics firm that leases floor space from a department store. (ii) Calculation of gross...

  5. Statistical analysis of the variation of floor vibrations in nuclear power plants subject to seismic loads

    International Nuclear Information System (INIS)

    Jussila, Vilho; Li, Yue; Fülöp, Ludovic

    2016-01-01

    Highlights: • Floor flexibility plays a non-negligible role in amplifying horizontal vibrations. • COV of in-floor horizontal and vertical acceleration are 0.15–0.25 and 0.25–0.55. • In-floor variation of vibrations is higher in lower floors. • Floor spectra from limited nodes underestimates vibrations by a factor of 1.5–1.75. - Abstract: Floor vibration of a reactor building subjected to seismic loads was investigated, with the aim of quantifying the variability of vibrations on each floor. A detailed 3D building model founded on the bedrock was excited simultaneously in three directions by artificial accelerograms compatible with Finnish ground response spectra. Dynamic simulation for 21 s was carried out using explicit time integration. The extracted results of the simulation were acceleration in several floor locations, transformed to pseudo-acceleration (PSA) spectra in the next stage. At first, the monitored locations on the floors were estimated by engineering judgement in order to arrive at a feasible number of floor nodes for post processing of the data. It became apparent that engineering judgment was insufficient to depict the key locations with high floor vibrations, which resulted in un-conservative vibration estimates. For this reason, a more systematic approach was later considered, in which nodes of the floors were selected with a more refined grid of 2 m. With this method, in addition to the highest PSA peaks in all directions, the full vibration distribution in each floor can be determined. A statistical evaluation of the floor responses was also carried out in order to define floor accelerations and PSAs with high confidence of non-exceedance. The conclusion was that in-floor variability can be as high as 50–60% and models with sufficiently dense node grids should be used in order to achieve a realistic estimate of floor vibration under seismic action. The effects of the shape of the input spectra, damping, and flexibility of the

  6. Statistical analysis of the variation of floor vibrations in nuclear power plants subject to seismic loads

    Energy Technology Data Exchange (ETDEWEB)

    Jussila, Vilho [VTT Technical Research Centre of Finland Ltd, Kemistintie 3, 02230 Espoo (Finland); Li, Yue [Dept. of Civil Engineering, Case Western Reserve University, Cleveland, OH 44106 (United States); Fülöp, Ludovic, E-mail: ludovic.fulop@vtt.fi [VTT Technical Research Centre of Finland Ltd, Kemistintie 3, 02230 Espoo (Finland)

    2016-12-01

    Highlights: • Floor flexibility plays a non-negligible role in amplifying horizontal vibrations. • COV of in-floor horizontal and vertical acceleration are 0.15–0.25 and 0.25–0.55. • In-floor variation of vibrations is higher in lower floors. • Floor spectra from limited nodes underestimates vibrations by a factor of 1.5–1.75. - Abstract: Floor vibration of a reactor building subjected to seismic loads was investigated, with the aim of quantifying the variability of vibrations on each floor. A detailed 3D building model founded on the bedrock was excited simultaneously in three directions by artificial accelerograms compatible with Finnish ground response spectra. Dynamic simulation for 21 s was carried out using explicit time integration. The extracted results of the simulation were acceleration in several floor locations, transformed to pseudo-acceleration (PSA) spectra in the next stage. At first, the monitored locations on the floors were estimated by engineering judgement in order to arrive at a feasible number of floor nodes for post processing of the data. It became apparent that engineering judgment was insufficient to depict the key locations with high floor vibrations, which resulted in un-conservative vibration estimates. For this reason, a more systematic approach was later considered, in which nodes of the floors were selected with a more refined grid of 2 m. With this method, in addition to the highest PSA peaks in all directions, the full vibration distribution in each floor can be determined. A statistical evaluation of the floor responses was also carried out in order to define floor accelerations and PSAs with high confidence of non-exceedance. The conclusion was that in-floor variability can be as high as 50–60% and models with sufficiently dense node grids should be used in order to achieve a realistic estimate of floor vibration under seismic action. The effects of the shape of the input spectra, damping, and flexibility of the

  7. Low-Impact Flooring: Does It Reduce Fall-Related Injuries?

    Science.gov (United States)

    Hanger, H Carl

    2017-07-01

    To compare fall rates and injuries from falls on low-impact flooring (LIF) compared with a standard vinyl flooring. Prospective, observational, nonrandomized controlled study. Subacute Older Persons Health ward (N = 20 beds). Older inpatients. Three different types of LIF. All falls in the ward were prospectively monitored using incident reporting, noting location and consequences of each fall. Fall rates (per 1000 bed days) and injuries, were compared between bedroom falls on LIF against those occurring on standard vinyl flooring (controls). Over 31 months, there were 278 bedroom falls (from 178 fallers). The bedroom fall rate (falls per 1000 bed days occupied) did not differ between the LIF and control groups (median 15 [IQR 8-18] versus 17 [IQR 9-23], respectively; P = .47). However, fall-related injuries were significantly less frequent when they occurred on LIFs (22% of falls versus 34% of falls on control flooring; P = .02). Fractures occurred in 0.7% of falls in the LIF cohort versus 2.3% in the control cohort. Rolling resistance when moving heavier equipment, such as beds or hoists, was an issue for staff on LIF. LIF significantly reduced fall-related injuries compared with a standard vinyl flooring, whereas they did not alter the overall risk of falling. Copyright © 2017 AMDA – The Society for Post-Acute and Long-Term Care Medicine. Published by Elsevier Inc. All rights reserved.

  8. Stochastic seismic floor response analysis method for various damping systems

    International Nuclear Information System (INIS)

    Kitada, Y.; Hattori, K.; Ogata, M.; Kanda, J.

    1991-01-01

    A study using the stochastic seismic response analysis method which is applicable for the estimation of floor response spectra is carried out. It is pointed out as a shortcoming in this stochastic seismic response analysis method, that the method tends to overestimate floor response spectra for low damping systems, e.g. 1% of the critical damping ratio. An investigation on the cause of the shortcoming is carried out and a number of improvements in this method were also made to the original method by taking correlation of successive peaks in a response time history into account. The application of the improved method to a typical BWR reactor building is carried out. The resultant floor response spectra are compared with those obtained by deterministic time history analysis. Floor response spectra estimated by the improved method consistently cover the response spectra obtained by the time history analysis for various damping ratios. (orig.)

  9. The relationship between gross motor skills and academic achievement in children with learning disabilities

    NARCIS (Netherlands)

    Westendorp, Marieke; Hartman, Esther; Houwen, Suzanne; Smith, Joanne; Visscher, Chris

    2011-01-01

    The present study compared the gross motor skills of 7- to 12-year-old children with learning disabilities (n = 104) with those of age-matched typically developing children (n = 104) using the Test of Gross Motor Development-2. Additionally, the specific relationships between subsets of gross motor

  10. Hardwood? Carpet? or Tile? A comparison of flooring costs under residential conditions

    Science.gov (United States)

    David G. Martens; David G. Martens

    1971-01-01

    Initial installation cost, annual maintenance cost, and total long-term cost are important in the purchase of flooring products. Before deciding on a flooring material, the prudent buyer will consider each of these in relation to his personal desires. From these evaluations, he will then be able to select the flooring material that is best suited to his individual...

  11. Carbon and nitrogen accumulation in forest floor and surface soil under different geographic origins of Maritime pine (Pinus pinaster Aiton.) plantations

    Energy Technology Data Exchange (ETDEWEB)

    Ozdemir, E.; Oral, H. V.; Akburak, S.; Makineci, E.; Yilmaz, E.

    2013-09-01

    Aim of study: To determine if plantations consisting of different geographic origins of the Maritime pine (Pinus pinaster Aiton.) could have altered C and N stocks in the forest floor and surface soils. Area of study: Forest floor and mineral soil C and N stocks were measured in four adjacent plantations of different geographic origins of Maritime pine (Gironde, Toulon, Corsica and Spain) and adjacent primary native Sessile oak (Quercus petraea L.) at Burunsuz region in Belgrad Forest where is located in the Istanbul province in the Marmara geographical region between 41° 09’-41° 12’ N latitude and 28° 54’-29° 00’ E longitude in Turkey. Material and methods: Plots were compared as common garden experiments without replications. 15 surface soil (0-10 cm) and 15 forest floor samples were taken from each Maritime pine origins and adjacent native Sessile oak forest. C and N contents were determined on LECO Truspec 2000 CN analyzer. The statistical significance of the results was evaluated by one-way Analysis of Variance (ANOVA). Research highlights: Forest floor carbon mass, nitrogen concentration and nitrogen mass of forest floor showed a significant difference among origins. Soil carbon mass and nitrogen mass did not significantly differ among investigated plots. (Author)

  12. Compilation of PRF Canyon Floor Pan Sample Analysis Results

    Energy Technology Data Exchange (ETDEWEB)

    Pool, Karl N. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Minette, Michael J. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Wahl, Jon H. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Greenwood, Lawrence R. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Coffey, Deborah S. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); McNamara, Bruce K. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Bryan, Samuel A. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Scheele, Randall D. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Delegard, Calvin H. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Sinkov, Sergey I. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Soderquist, Chuck Z. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Fiskum, Sandra K. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Brown, Garrett N. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Clark, Richard A. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States)

    2016-06-30

    On September 28, 2015, debris collected from the PRF (236-Z) canyon floor, Pan J, was observed to exhibit chemical reaction. The material had been transferred from the floor pan to a collection tray inside the canyon the previous Friday. Work in the canyon was stopped to allow Industrial Hygiene to perform monitoring of the material reaction. Canyon floor debris that had been sealed out was sequestered at the facility, a recovery plan was developed, and drum inspections were initiated to verify no additional reactions had occurred. On October 13, in-process drums containing other Pan J material were inspected and showed some indication of chemical reaction, limited to discoloration and degradation of inner plastic bags. All Pan J material was sealed back into the canyon and returned to collection trays. Based on the high airborne levels in the canyon during physical debris removal, ETGS (Encapsulation Technology Glycerin Solution) was used as a fogging/lock-down agent. On October 15, subject matter experts confirmed a reaction had occurred between nitrates (both Plutonium Nitrate and Aluminum Nitrate Nonahydrate (ANN) are present) in the Pan J material and the ETGS fixative used to lower airborne radioactivity levels during debris removal. Management stopped the use of fogging/lock-down agents containing glycerin on bulk materials, declared a Management Concern, and initiated the Potential Inadequacy in the Safety Analysis determination process. Additional drum inspections and laboratory analysis of both reacted and unreacted material are planned. This report compiles the results of many different sample analyses conducted by the Pacific Northwest National Laboratory on samples collected from the Plutonium Reclamation Facility (PRF) floor pans by the CH2MHill’s Plateau Remediation Company (CHPRC). Revision 1 added Appendix G that reports the results of the Gas Generation Rate and methodology. The scope of analyses requested by CHPRC includes the determination of

  13. Seismic isolation floor and vibration control equipment for nuclear power plant

    International Nuclear Information System (INIS)

    Niwa, H.; Fujimoto, S.; Aida, Y.; Miyano, H.

    1996-01-01

    We have developed a seismic isolation floor to improve protection against earthquakes for process computer systems, and a magnetic dynamic damper to reduce the mechanical vibrations of piping systems and pumps in nuclear power plants. Seismic excitation tests of the seismic isolation floor, on which process computer systems were installed, were performed using large earthquake simulators. The test results proved that the seismic isolation floor significantly reduced seismic forces. To control mechanical vibrations, a magnetic dynamic damper was designed using permanent magnets. This magnetic dynamic damper does not require mechanical springs, dampers and supports in the floors and walls of the building. Vibration tests using a rotating machine model confirmed that the magnetic dynamic damper effectively controlled vibrations in such a rotating machine model. (author)

  14. Modal analysis for floors in lightweight buildings

    DEFF Research Database (Denmark)

    Sjökvist, Lars-Göran; Brunskog, Jonas

    2007-01-01

    of acoustical prediction methods for those houses. The calculation standard EN 12354 is under evaluation since it cannot include most of the wooden houses that are built. It is important during such a work to have a great understanding of the acoustical behaviour for the wooden houses. The floors in lightweight...... constructions usually consist of plates that are stiffened by beams and by the dividing walls. In this study the wave equation for a plate is expanded by Fourier series and an analytical solution in terms of the eigenmodes of the entire system is presented. The studied system consists of one lightweigt floor...

  15. Coatings and floor covers for nuclear applications

    International Nuclear Information System (INIS)

    Kunze, S.

    1998-01-01

    To prevent damage to, or even the destruction of, components of very sensitive electrical equipment in rooms in which unsealed radioactive emitters are handled, floors must be antistatic and capable of being decontaminated. Conductive additives to the cover compounds achieve the desired leakage resistance of 5.10 4 to 10 6 Ω. Investigations have shown the decontamination capability of all floor covers and coatings to be excellent in most cases, and good in a few cases. Except for one coating, the coatings examined after radiation exposure also meet the requirements applying to nuclear installations. (orig.) [de

  16. Acoustics advances study of sea floor hydrothermal flow

    Science.gov (United States)

    Rona, Peter A.; Jackson, Darrell R.; Bemis, Karen G.; Jones, Christopher D.; Mitsuzawa, Kyohiko; Palmer, David R.; Silver, Deborah

    Sub-sea floor hydrothermal convection systems discharge as plumes from point sources and as seepage from the ocean bottom. The plumes originate as clear, 150-400°C solutions that vent from mineralized chimneys; precipitate dissolved metals as particles to form black or white smokers as they turbulently mix with ambient seawater; and buoyantly rise hundreds of meters to a level of neutral density where they spread laterally. The seepage discharges from networks of fractures at the rock-water interface as clear, diffuse flow, with lower temperatures, metal contents, and buoyancy than the smokers. The diffuse flow may be entrained upward into plumes, or laterally by prevailing currents in discrete layers within tens of meters of the sea floor. The role of these flow regimes in dispersing heat, chemicals, and biological material into the ocean from sub-sea floor hydrothermal convection systems is being studied on a global scale.

  17. Surficial geology of the sea floor in Long Island Sound offshore of Plum Island, New York

    Science.gov (United States)

    McMullen, K.Y.; Poppe, L.J.; Danforth, W.W.; Blackwood, D.S.; Schaer, J.D.; Ostapenko, A.J.; Glomb, K.A.; Doran, E.F.

    2010-01-01

    The U.S. Geological Survey (USGS), the Connecticut Department of Environmental Protection, and the National Oceanic and Atmospheric Administration (NOAA) have been working cooperatively to interpret surficial sea-floor geology along the coast of the Northeastern United States. NOAA survey H11445 in eastern Long Island Sound, offshore of Plum Island, New York, covers an area of about 12 square kilometers. Multibeam bathymetry and sidescan-sonar imagery from the survey, as well as sediment and photographic data from 13 stations occupied during a USGS verification cruise are used to delineate sea-floor features and characterize the environment. Bathymetry gradually deepens offshore to over 100 meters in a depression in the northwest part of the study area and reaches 60 meters in Plum Gut, a channel between Plum Island and Orient Point. Sand waves are present on a shoal north of Plum Island and in several smaller areas around the basin. Sand-wave asymmetry indicates that counter-clockwise net sediment transport maintains the shoal. Sand is prevalent where there is low backscatter in the sidescan-sonar imagery. Gravel and boulder areas are submerged lag deposits produced from the Harbor Hill-Orient Point-Fishers Island moraine segment and are found adjacent to the shorelines and just north of Plum Island, where high backscatter is present in the sidescan-sonar imagery.

  18. Effects of floor eggs on hatchability and later life performance in broiler chickens.

    Science.gov (United States)

    van den Brand, H; Sosef, M P; Lourens, A; van Harn, J

    2016-05-01

    Two experiments were conducted in which effects of floor eggs, washed floor eggs, and clean nest eggs were investigated on incubation characteristics and performance in later life of broiler chickens. In both experiments, a young and an older breeder flock were used in a 3×2 factorial design during incubation. In the second experiment, male and female chickens were reared separately until d 35 of age in floor pens. During this grow out trial, an extra group was created in which chickens obtained from clean nest eggs were mixed with chickens obtained from floor eggs, meaning that grow out period was set up as a 4×2×2 factorial design with 4 egg types, 2 breeder ages, and 2 sexes. In both experiments, fertility and hatchability of fertile eggs were lower in floor and washed eggs than in clean nest eggs (hatchability: experiment 1: 74.4 vs. 70.6 vs. 92.6% for floor eggs, washed floor eggs and clean nest eggs, respectively, P<0.001; experiment 2: 78.3 vs. 81.7 vs. 90.2%, respectively, P<0.001). In experiment 2, BW at d 0 of chickens obtained from clean nest eggs was higher than that of chickens from floor eggs and washed floor eggs (41.5 vs. 40.4 and 40.3 g, respectively; P<0.001). This difference disappeared during the grow out period and was absent at slaughter age at d 35 of age. Feed intake (FI), feed conversion ratio (FCR), and mortality during the grow out period were not affected by egg type. Incidence and severity of hock burns and footpad dermatitis were not affected by egg type or breeder age. Litter friability at d 35 of age tended to be lower in pens with chickens obtained from washed floor eggs compared to clean nest eggs. We conclude that incubation of floor eggs or washed floor eggs resulted in lower fertility and hatchability compared to clean nest eggs, but that performance during the grow out period was not affected. © 2016 Poultry Science Association Inc.

  19. Criteria for requesting specific radionuclide analysis through gross α and gross β concentration measurements in environmental samples

    International Nuclear Information System (INIS)

    Ferreira, E.G.

    1988-01-01

    This paper suggests some criteria for the decision to proceed with the analysis of specific radionuclides based on results of the determination of gross α and β concentrations in environmental samples of aerosols, water, dairy and agricultural products, soil and sediments. The samples considered are provenient from the environmental surveillance of uranium mining and milling facilities as well as the mining and processing plants of monazite sands. The radionuclides to be analysed are those considered to be the most critical to human health, that is: U-nat; Th-nat; Th-230; Ra-228; Ra-226; Po-210; Pb-210. The measured gross α and β concentrations will be compared with the Maximum Allowable Concentrations for some defined radionuclides. Radiochemical analysis of specific radionuclides may then become necessary, depending upon the results of this comparison. The main goal of the proposed guide is to simplify and to discipline the execution of environmental surveillance programs in a safe and economical way, avoiding unnecessary analysis. (author) [pt

  20. [Perioperative nursing of internal sinus floor elevation surgery with piezosurgery].

    Science.gov (United States)

    He, Jing; Lei, Yiling; Wang, Liqiong

    2013-12-01

    This study aims to summarize the nursing experience in the internal sinus floor elevation surgery with piezosurgery. The medical records of 48 patients who underwent sinus floor elevation surgery with piezosurgery in the Department of Implantation, West China Hospital of Stomatology, Sichuan University, were reviewed. The preoperative, intraoperative, and postoperative nursing methods were summarized. All 48 patients underwent smooth surgeries and did not encounter complications. Careful preoperative preparation, careful and meticulous intraoperative nursing cooperation, and provision of sufficient health education after surgery to the patients are the key factors that ensure the success of internal sinus floor elevation surgery with piezosurgery.

  1. Pelvic Muscle Rehabilitation: A Standardized Protocol for Pelvic Floor Dysfunction

    Directory of Open Access Journals (Sweden)

    Rodrigo Pedraza

    2014-01-01

    Full Text Available Introduction. Pelvic floor dysfunction syndromes present with voiding, sexual, and anorectal disturbances, which may be associated with one another, resulting in complex presentation. Thus, an integrated diagnosis and management approach may be required. Pelvic muscle rehabilitation (PMR is a noninvasive modality involving cognitive reeducation, modification, and retraining of the pelvic floor and associated musculature. We describe our standardized PMR protocol for the management of pelvic floor dysfunction syndromes. Pelvic Muscle Rehabilitation Program. The diagnostic assessment includes electromyography and manometry analyzed in 4 phases: (1 initial baseline phase; (2 rapid contraction phase; (3 tonic contraction and endurance phase; and (4 late baseline phase. This evaluation is performed at the onset of every session. PMR management consists of 6 possible therapeutic modalities, employed depending on the diagnostic evaluation: (1 down-training; (2 accessory muscle isolation; (3 discrimination training; (4 muscle strengthening; (5 endurance training; and (6 electrical stimulation. Eight to ten sessions are performed at one-week intervals with integration of home exercises and lifestyle modifications. Conclusions. The PMR protocol offers a standardized approach to diagnose and manage pelvic floor dysfunction syndromes with potential advantages over traditional biofeedback, involving additional interventions and a continuous pelvic floor assessment with management modifications over the clinical course.

  2. COST OF PRODUCTION, GROSS RETURN AND NET PROFIT IN COMMERCIAL EGG PRODUCTION

    Directory of Open Access Journals (Sweden)

    M. Farooq, Zahoor-ul-Haq1, M.A. Mian, F.R. Durrani and M. Syed

    2003-01-01

    Full Text Available The present study was carried out in Chakwal, Pakistan by collecting data from randomly selected 109 flocks to investigate cost of production, gross return and net profit per layer. Majority of the buildings in the study area were rented therefore, rent per layer was added to the total cost of production instead of depreciation on building and equipments. Overall total cost of production, gross return and net profit per layer was Rs. 393.88 ± 5.36, 432.14 ± 8.01 and 38.26 ± 6.66, respectively. Rate of return over the invested capital was 27%. Mean feed cost per layer was Rs. 302.23 ± 5.01, including Rs. 10.27 ± 0.24, 29.19 ± 0.42 and 262.77 ± 5.08 for starter, grower and layer ration, respectively. Feed cost was the major component contributing 76.73% to the total cost of production. Average cost of labor, day-old chick, building rent, vaccination, therapy, miscellaneous item, electricity, bedding material and transportation was Rs. 19.90 ± 0.45, 19.75 ± 0.05, 16.25 ± 0.26, 12.80 ± 0.10, 10.90 ± 2.32, 4.35 ± 0.09, 3.15 ± 0.07, 2.65 ± 0.09 and 1.90 ± 0.08, respectively, contributing 5.05, 5.01, 4.13, 3.25, 2.77, 1.10, 0.80, 0.67 and 0.48 % to the total cost of production. Gross return from the sale of marketable eggs, culled eggs, spent/culled bird, empty bags and manure was Rs. 388.84 ± 7.91, 3.85 ± 0.01, 35.80 ± 0.23, 2.20 ± 0.04 and 1.45 ± 0.01, respectively, contributing 89.98, 0.89, 8.28, 0.51 and 0.34% to the total return. Determining the effect of different parameters on the cost of production and net profit, large flocks, Hisex strain, brood-grow and lay system of rearing, good hygienic conditions of the farm, normal stocking rate and cage system of housing wee found to give maximum gross return as well as net profit.

  3. Gross xenon stability

    International Nuclear Information System (INIS)

    Lewins, J.D.; Wilson, P.P.H.

    1997-01-01

    The effect of xenon in thermal reactors on steady operation is generally destabilizing. Illustrating this involves the study of appropriate transfer functions, which may be conveniently displayed in three ways: as Bode, Nyquist, and root-locus diagrams. The three forms allow different aspects to be highlighted. These are illustrated for the effect of xenon with allowance not only for the stabilizing effect of the direct yield in fission but also to show the consequences of neglecting the time dependence due to the thermal capacity of the reactor. With careful interpretation, all these forms give an interpretation of stability that is consistent with direct evaluation and promote the understanding of the onset of gross oscillations in power

  4. Rubber Flooring Impact on Production and Herdlife of Dairy Cows

    Science.gov (United States)

    Use of rubber flooring in dairies has become popular because of perceived cow comfort. The overall objective of this longitudinal study was to evaluate production, reproduction, and retention of first and second lactations of cows assigned to either rubber (RUB) or concrete (CON) flooring at the fe...

  5. CURB-BASED STREET FLOOR EXTRACTION FROM MOBILE TERRESTRIAL LIDAR POINT CLOUD

    Directory of Open Access Journals (Sweden)

    S. Ibrahim

    2012-07-01

    Full Text Available Mobile terrestrial laser scanners (MTLS produce huge 3D point clouds describing the terrestrial surface, from which objects like different street furniture can be generated. Extraction and modelling of the street curb and the street floor from MTLS point clouds is important for many applications such as right-of-way asset inventory, road maintenance and city planning. The proposed pipeline for the curb and street floor extraction consists of a sequence of five steps: organizing the 3D point cloud and nearest neighbour search; 3D density-based segmentation to segment the ground; morphological analysis to refine out the ground segment; derivative of Gaussian filtering to detect the curb; solving the travelling salesman problem to form a closed polygon of the curb and point-inpolygon test to extract the street floor. Two mobile laser scanning datasets of different scenes are tested with the proposed pipeline. The results of the extracted curb and street floor are evaluated based on a truth data. The obtained detection rates for the extracted street floor for the datasets are 95% and 96.53%. This study presents a novel approach to the detection and extraction of the road curb and the street floor from unorganized 3D point clouds captured by MTLS. It utilizes only the 3D coordinates of the point cloud.

  6. A Radiologic Study of the Relationship of the Maxillary Sinus Floor and Apex of the Maxillary Molar

    International Nuclear Information System (INIS)

    Yoon, Hae Rym; Park, Chang Seo

    1998-01-01

    the vertical relationship of the maxillary sinus floor and maxillary roots was assessed, in 1st molars, type II (the sinus floor that extends down to the buccolingual furcation area) was predominant, while in 2nd molars, type I (the sinus floor located above the level connecting the buccal and lingual apices) was predominant. In the horizontal relationship, in 1st olars, type II (ths lowest floor of the maxillary sinus located in between the buccal and lingual roots) was predominant; in 2nd molars, type I (the lowest floor of the maxillary sinus located on the buccal side of the buccal roots) and type II appeared in similar frequency. In conclusion, the SCANORA cross-sectional tomography was more effective than the frequently used panoramic view, in that the relationship of the maxillary molars and maxillary sinus floor can be evaluated more accurately and the buccolingual cross-sectional view can also be observed. And maxillary sinus floor that was close to maxillary 2nd molar had tendency to be located on buccal side than that close to 1st molar. Therefore, cross-sectional tomography is an effective and accurate method to evaluate the position of the teeth in relation to the sinus floor preoperative and can be easily used to diagnose localized periapical lesions. Also the image quality obtained was quite satisfactory.

  7. 26 CFR 41.4482(b)-1 - Definition of taxable gross weight.

    Science.gov (United States)

    2010-04-01

    ... Motor Vehicles § 41.4482(b)-1 Definition of taxable gross weight. (a) Actual unloaded weight—(1) In... general. The taxable gross weight of a highway motor vehicle is the sum of the actual unloaded weight of the vehicle fully equipped for service, the actual unloaded weight of any semitrailers or trailers...

  8. The Role of Pelvic Floor Muscles in Male Sexual Dysfunction and Pelvic Pain.

    Science.gov (United States)

    Cohen, Deborah; Gonzalez, Joshua; Goldstein, Irwin

    2016-01-01

    Sexual function is essential to good health and well-being in men. The relationship between male sexual function, pelvic floor function, and pelvic pain is complex and only beginning to be appreciated. The objectives of the current review are to examine these complex relationships, and to demonstrate how pelvic floor physical therapy can potentially improve the treatment of various male sexual dysfunctions, including erectile dysfunction and dysfunction of ejaculation and orgasm. Contemporary data on pelvic floor anatomy and function as they relate to the treatment of various male sexual dysfunctions were reviewed. Examination of evidence supporting the association between the male pelvic floor and erectile dysfunction, ejaculatory/orgasmic dysfunction, and chronic prostatitis/chronic pelvic pain syndrome, respectively. Evidence suggests a close relationship between the pelvic floor and male sexual dysfunction and a potential therapeutic benefit from pelvic floor therapy for men who suffer from these conditions. Pelvic floor physical therapy is a necessary tool in a more comprehensive bio-neuromusculoskeletal-psychosocial approach to the treatment of male sexual dysfunction and pelvic pain. Copyright © 2016 International Society for Sexual Medicine. Published by Elsevier Inc. All rights reserved.

  9. Selection criteria and requirements for floors in nuclear facilities

    International Nuclear Information System (INIS)

    Kunze, S.

    1988-01-01

    As a surface protection of floors in nuclear facilities coatings, rubber and PVC coverings, respectively, are normally used, whereas stoneware tiles are still provided in rare cases only. All floor materials must be well decontaminable according to the German standard DIN 25415, Part 1. The general requirement is that low-porous, smooth products with little filler content, made of chemically resistant material, are very well decontaminable. Further investigations will be necessary for heavily loaded floor coatings. They include above all examinations for decontaminability after radiation and for wear and resistance to chemicals. These requirements have been compiled in DIN 55991. The examination of about 212 industrial products has revealed that the decontaminability of covering materials is frequently poor. Investigations have shown that the decontaminability is always deteriorated by additions of hygroscopic fillers. Additions of non-hygroscopic fillers and pigments may result in an excellent to poor decontaminability. The pore-free bonding of the covering materials by welding or jointing is of great importance with respect to the decontaminability of these floors. Care should be taken that the jointing compounds are as well decontaminable as the rubber coverings and stonewares. (orig.) [de

  10. Selection criteria and requirements for floors in nuclear plants

    International Nuclear Information System (INIS)

    Kunze, S.

    1987-01-01

    As a surface protection of floors in nuclear facilities coatings, rubber and PVC coverings, respectively, are normally used, whereas stoneware tiles are still provided in rare cases only. All floor materials must be well decontaminable according to the German standard DIN 25415, Part 1. The general requirement is that low-porous, smooth products with little filler content, made of chemically resistant material, are very well decontaminable. Further investigations will be necessary for heavily loaded floor coatings. They include above all examinations for decontaminability after radiation and for wear and resistance to chemicals. These requirements have been compiled in DIN 55991. The examination of about 200 industrial products has revealed that the decontaminability of covering materials is frequently poor. Investigations have shown that the decontaminability is always deteriorated by additions of hygroscopic fillers. Additions of non-hygroscopic fillers and pigments may result in an excellent to poor decontaminability. The pore-free bonding of the covering materials by welding or jointing is of great importance with respect to the decontaminability of these floors. Care should be taken that the jointing compounds are as well decontaminable as the rubber coverings and stonewares. (orig.) [de

  11. Virtual reality: new method of teaching anorectal and pelvic floor anatomy.

    Science.gov (United States)

    Dobson, Howard D; Pearl, Russell K; Orsay, Charles P; Rasmussen, Mary; Evenhouse, Ray; Ai, Zhuming; Blew, Gregory; Dech, Fred; Edison, Marcia I; Silverstein, Jonathan C; Abcarian, Herand

    2003-03-01

    A clear understanding of the intricate spatial relationships among the structures of the pelvic floor, rectum, and anal canal is essential for the treatment of numerous pathologic conditions. Virtual-reality technology allows improved visualization of three-dimensional structures over conventional media because it supports stereoscopic-vision, viewer-centered perspective, large angles of view, and interactivity. We describe a novel virtual reality-based model designed to teach anorectal and pelvic floor anatomy, pathology, and surgery. A static physical model depicting the pelvic floor and anorectum was created and digitized at 1-mm intervals in a CT scanner. Multiple software programs were used along with endoscopic images to generate a realistic interactive computer model, which was designed to be viewed on a networked, interactive, virtual-reality display (CAVE or ImmersaDesk). A standard examination of ten basic anorectal and pelvic floor anatomy questions was administered to third-year (n = 6) and fourth-year (n = 7) surgical residents. A workshop using the Virtual Pelvic Floor Model was then given, and the standard examination was readministered so that it was possible to evaluate the effectiveness of the Digital Pelvic Floor Model as an educational instrument. Training on the Virtual Pelvic Floor Model produced substantial improvements in the overall average test scores for the two groups, with an overall increase of 41 percent (P = 0.001) and 21 percent (P = 0.0007) for third-year and fourth-year residents, respectively. Resident evaluations after the workshop also confirmed the effectiveness of understanding pelvic anatomy using the Virtual Pelvic Floor Model. This model provides an innovative interactive educational framework that allows educators to overcome some of the barriers to teaching surgical and endoscopic principles based on understanding highly complex three-dimensional anatomy. Using this collaborative, shared virtual-reality environment

  12. Experimental Investigation of the Influence of Different Flooring Emissivity on Night-Time Cooling using Displacement Ventilation

    DEFF Research Database (Denmark)

    Le Dréau, Jérôme; Karlsen, Line Røseth; Litewnicki, Michal

    2011-01-01

    , but it was seen that the emissivity of the flooring affected the heat transfer ratio at the internal surfaces. The convective heat flux increased at the ceiling and decreased at the floor for experiments with aluminum flooring compared to the experiments with EPS floor. Temperature efficiency was slightly higher......-time ventilation using displacement ventilation. Experimental work was conducted on the basis of the work performed by Artmann et al. (2009) in a similar previous study. An aluminum-foil floor cover was installed in a full scale test room. Experimental results obtained with aluminum flooring were compared...... to results obtained by Artmann et al. with a flooring consisting of expanded polystyrene (EPS). Results showed that the surface temperature of the floor decreased with decreasing emissivity. Mean convective heat fluxes were similar for experiments conducted with both EPS and aluminum-foil floor cover...

  13. Environmental burdens of a Finnish indoor swimming pool; Uimahallin ympaeristoekuormitukset

    Energy Technology Data Exchange (ETDEWEB)

    Vaahterus, T.; Saari, A.

    2001-07-01

    In this study the environmental burdens of a Finnish indoor swimming pool generated by its energy consumption were calculated. The calculations were made by using a calculation method based on LCA methodology. Calculations were made of 50 years period. The energy consumption dating from the time of the indoor swimming pool causes towards the gross-floor area a nearly four times bigger environmental load than for example a block of flats and indoor ice- skating rink. On a block of flats and indoor ice-skating rink the energy consumption dating from the time of the use causes more than 90 % of the environmental burdens of the whole life span. One can suppose that at the indoor swimming pool the share of the energy consumption dating from the time of the use only is emphasized. In this study confine therefore to dealing with the environmental loads caused only by the energy consumption dating from the time of the use. The results of these calculations showed that the energy flow of the life cycle energy consumption was 193 000 MJ/brm{sup 2}. 11,2 ton per gross-floor area CO{sub 2} equivalents, 21 kg per gross-floor area SO{sub 2} equivalents and 290 g per gross-floor area ethene equivalents of environmental burdens were caused. The main factor causing the most environmental loads were the need of heating energy. The need of heating energy produced 75 % of the CO{sub 2} equivalents, 70 % of the SO{sub 2} equivalents and 59 % of the ethene equivalents. The need of the electric energy produced 23 % of the CO{sub 2} equivalents, 23 % of the SO{sub 2} equivalents and 17 % of the ethene equivalents. Of the heating energy the share of the warming of water was 56 %. The most significant part of the electric energy were consumed in the use of the sauna stoves and vapor sauna (31 %) and heating pumps and water elements (30 %). Almost all (87 %) of the energy, consumed during the life cycle, was produced with non-renewable energy sources. The source information of the energy was

  14. Energy absorption during impact on the proximal femur is affected by body mass index and flooring surface.

    Science.gov (United States)

    Bhan, Shivam; Levine, Iris C; Laing, Andrew C

    2014-07-18

    Impact mechanics theory suggests that peak loads should decrease with increase in system energy absorption. In light of the reduced hip fracture risk for persons with high body mass index (BMI) and for falls on soft surfaces, the purpose of this study was to characterize the effects of participant BMI, gender, and flooring surface on system energy absorption during lateral falls on the hip with human volunteers. Twenty university-aged participants completed the study with five men and five women in both low BMI (27.5 kg/m(2)) groups. Participants underwent lateral pelvis release experiments from a height of 5 cm onto two common floors and four safety floors mounted on a force plate. A motion-capture system measured pelvic deflection. The energy absorbed during the initial compressive phase of impact was calculated as the area under the force-deflection curve. System energy absorption was (on average) 3-fold greater for high compared to low BMI participants, but no effects of gender were observed. Even after normalizing for body mass, high BMI participants absorbed 1.8-fold more energy per unit mass. Additionally, three of four safety floors demonstrated significantly increased energy absorption compared to a baseline resilient-rolled-sheeting system (% increases ranging from 20.7 to 28.3). Peak system deflection was larger for high BMI persons and for impacts on several safety floors. This study indicates that energy absorption may be a common mechanism underlying the reduced risk of hip fracture for persons with high BMI and for those who fall on soft surfaces. Crown Copyright © 2014. Published by Elsevier Ltd. All rights reserved.

  15. The Relationship between Gross Motor Skills and Academic Achievement in Children with Learning Disabilities

    Science.gov (United States)

    Westendorp, Marieke; Hartman, Esther; Houwen, Suzanne; Smith, Joanne; Visscher, Chris

    2011-01-01

    The present study compared the gross motor skills of 7- to 12-year-old children with learning disabilities (n = 104) with those of age-matched typically developing children (n = 104) using the Test of Gross Motor Development-2. Additionally, the specific relationships between subsets of gross motor skills and academic performance in reading,…

  16. Intrahepatic cholangiocarcinoma : gross appearance and corresponding pathologic and radiologic features

    International Nuclear Information System (INIS)

    Yoon, Kwon Ha; Kim, Chang Guhn; Lee, Moon Gyu; Ha, Hyun Kwon; Auh, Yong Ho; Lim, Jae Hoon

    1999-01-01

    To assess the clinical and pathologic features of each type of intrahepatic cholangiocarcinoma, which is divided into three types according to gross appearance, and to determine the efficacy of CT in detecting this tumor. The pathologic and CT features of 53 surgically proven cases of intrahepatic cholangio-carcinoma were reviewed. On the basis of their gross appearance, the tumors were divided into three types, as follows : mass forming (n=33), periductal infiltrating (n=6), and intraductal growth type (n=14). CT scans were analyzed for sensitivity of detection and correlation between a tumors appearance and its histopathology. The most common histopathologic feature of mass forming and periductal infiltrating type was tubular adenocarcinoma, while in the intraductal growth type, papillary adenocarcinoma (100%) was common. With regard to pattern of tumor spread, intrahepatic and lymph node metastasis were more common in the mass forming and periductal infiltrating type than in the intraductal growth type. CT findings including intrahepatic mass, ductal wall thickening or intraductal mass associated with segmental dilatation of intrahepataic bile ducts, corresponded with these morphologic types. This classification according to gross appearance is of considerable value when interpreting the pathologic features of intrahepatic cholangiocarcinoma. CT seems to be a useful modality for the detection of tumors and may be consistent with their gross morphologic findings

  17. Measurement of gross beta radioactivity in high-level liquid waste

    International Nuclear Information System (INIS)

    Lu Feng; Lin Cansheng; Zhang Xianzi; Chen Guoan; Zhang Chonghai

    1992-01-01

    Using beta plastic scintillation counter of low level background, gross beta radioactivity of twelve samples for high-level liquid waste is determined directly. Beta efficiency curves of plastic scintillation counter for four mass thickness are calibrated in advance. Determining gross beta radioactivity, gross efficiency of the scintillation counter for various energy beta ray is calculated via weighted mean method with the ratio of radioactivity for each nuclide. The ratio of radioactivity for nuclides which have gamma disintegration is determined in terms of the radioactivity measured by gamma spectrometer. The ratio of the radioactivity for 90 Sr which has purity beta disintegration is calculated in terms of half life time approximation. The ratio of the radioactivity for 147 Pm which also has purity disintegration is calculated by means of apparent cooling-time approximation. The uncertainty of results for the present work is about +-15%

  18. Acoustics. Measurement of sound insulation in buildings and of building elements. Laboratory measurements of the reduction of transmitted impact noise by floor coverings on a heavyweight standard floor

    CERN Document Server

    British Standards Institution. London

    1998-01-01

    Acoustics. Measurement of sound insulation in buildings and of building elements. Laboratory measurements of the reduction of transmitted impact noise by floor coverings on a heavyweight standard floor

  19. The implications of particle energy and acidic media on gross alpha and gross beta determination using liquid scintillation

    Energy Technology Data Exchange (ETDEWEB)

    Zapata-Garcia, D. [Laboratori de Radiologia Ambiental (LRA), Departament de Quimica Analitica, Universitat de Barcelona, Marti i Franques, 1-11 Planta 3, E-08028 Barcelona (Spain); Llaurado, M., E-mail: montse.llaurado@ub.edu [Laboratori de Radiologia Ambiental (LRA), Departament de Quimica Analitica, Universitat de Barcelona, Marti i Franques, 1-11 Planta 3, E-08028 Barcelona (Spain); Rauret, G. [Laboratori de Radiologia Ambiental (LRA), Departament de Quimica Analitica, Universitat de Barcelona, Marti i Franques, 1-11 Planta 3, E-08028 Barcelona (Spain)

    2012-04-15

    The interaction of humans with radioactivity present in the environment from natural and artificial sources necessitates an evaluation of its risk on human health. Gross alpha and gross beta activities can provide a rapid evaluation of the radioactive content of a sample and can be simultaneously determined by using liquid scintillation counters. However, calibration of the liquid scintillation counter is required and is affected by many factors, such as particle energy and the acidity of the media. This study investigates what effect the particle energy used for calibration has on misclassification and how to account for this misclassification in routine measurements. The variability in measurement produced by the final pH, as well as any acids used in sample treatment, was also studied. These results showed that the most commonly used acid for these types of analyses, HNO{sub 3}, produced a high amount of misclassifications at very low pH. The results improved when HCl was used to adjust the sample to low pH. - Highlights: Black-Right-Pointing-Pointer We study the effect of alpha and beta energies on PSA optimisation. Black-Right-Pointing-Pointer The optimum PSA shifts to higher values as the alpha energy increases. Beta energies do not affect it. Black-Right-Pointing-Pointer We study the effect of pH on the simultaneous determination of gross alpha/beta activities. Black-Right-Pointing-Pointer HNO{sub 3} produces a high amount of misclassification at very low pH. Black-Right-Pointing-Pointer The results improve when HCl is used to adjust the sample to low pH.

  20. The implications of particle energy and acidic media on gross alpha and gross beta determination using liquid scintillation

    International Nuclear Information System (INIS)

    Zapata-García, D.; Llauradó, M.; Rauret, G.

    2012-01-01

    The interaction of humans with radioactivity present in the environment from natural and artificial sources necessitates an evaluation of its risk on human health. Gross alpha and gross beta activities can provide a rapid evaluation of the radioactive content of a sample and can be simultaneously determined by using liquid scintillation counters. However, calibration of the liquid scintillation counter is required and is affected by many factors, such as particle energy and the acidity of the media. This study investigates what effect the particle energy used for calibration has on misclassification and how to account for this misclassification in routine measurements. The variability in measurement produced by the final pH, as well as any acids used in sample treatment, was also studied. These results showed that the most commonly used acid for these types of analyses, HNO 3 , produced a high amount of misclassifications at very low pH. The results improved when HCl was used to adjust the sample to low pH. - Highlights: ► We study the effect of alpha and beta energies on PSA optimisation. ► The optimum PSA shifts to higher values as the alpha energy increases. Beta energies do not affect it. ► We study the effect of pH on the simultaneous determination of gross alpha/beta activities. ► HNO 3 produces a high amount of misclassification at very low pH. ► The results improve when HCl is used to adjust the sample to low pH.

  1. Total Strain FE Model for Reinforced Concrete Floors on Piles

    NARCIS (Netherlands)

    Hofmeyer, H.; Bos, van den A.A.

    2008-01-01

    A finite element (FE) model using a total strain material model has been developed to predict the behavior of warehouse reinforced concrete floors on piles. The material model (not the FE model itself) was calibrated to material tests. The FE model for the floor structure was checked with full-scale

  2. Development of automatic smear testing sampler for radioactive contamination of floor in nuclear power plant

    International Nuclear Information System (INIS)

    Nozawa, Katsuro; Hashimoto, Hiroshi; Shinohara, Yohtaro; Iwaki, Kiyotaka

    1980-01-01

    The floor contamination with radioactive substances in the controlled area of nuclear power stations is strictly controlled, and it is tested by the smear method, wiping the contaminants on floors with filter papers or cloths and measuring the radioactive intensity to obtain contamination density. The works are very laborious, therefore the automatic smear sampler was developed. Simple operation, shortening of time required for wiping, constant and high efficiency of wiping, and easy numbering of samples were the aims in the development. The method of wiping, the mechanisms of wiping, cloth feeding and running, the surface pressure at the time of wiping, the number of times of wiping and required motor torque were studied. The outline of the developed sampler is explained. The performance of the sampler was compared with manual wiping. The efficiency of wiping with the sampler was 92%, assuming manual wiping as 100. Difference was not observed between careful manual wiping and the wiping with the sampler, therefore it was confirmed that this automatic floor smear sampler can be put in practical use. By conventional manual sampling, the maximum limit was about 400 samples/man-day, but when this sampler is used, about 1000 samples/sampler-day is possible. At present, this sampler is operated in Hamaoka Nuclear Power Station. (Kako, I.)

  3. Gross-Pitaevski map as a chaotic dynamical system.

    Science.gov (United States)

    Guarneri, Italo

    2017-03-01

    The Gross-Pitaevski map is a discrete time, split-operator version of the Gross-Pitaevski dynamics in the circle, for which exponential instability has been recently reported. Here it is studied as a classical dynamical system in its own right. A systematic analysis of Lyapunov exponents exposes strongly chaotic behavior. Exponential growth of energy is then shown to be a direct consequence of rotational invariance and for stationary solutions the full spectrum of Lyapunov exponents is analytically computed. The present analysis includes the "resonant" case, when the free rotation period is commensurate to 2π, and the map has countably many constants of the motion. Except for lowest-order resonances, this case exhibits an integrable-chaotic transition.

  4. GLOBALIZATION AND GROSS DOMESTIC PRODUCT CONSTRUCTION IN ASEAN

    Directory of Open Access Journals (Sweden)

    Muhammad Sri Wahyudi Suliswanto

    2011-09-01

    Full Text Available There is no more doubt about the importance of economic growth, which can be calculated fromGross Domestic Product (GDP. This research analyzes the role of globalization on GDP inASEAN-5 by estimating panel data. It uses a fixed effect approach to accommodate various characteristicsin the countries. To accommodate such variation, it assumes that the intercepts variesacross these countries, while the slopes remain similar. Based on the estimation result, it suggeststhat net export and foreign direct investment represent the globalization process. Both have positiveand significant influences on GDP in the corresponding countries.Keywords: Globalization, international trade, foreign direct investment, gross domestic productJEL classification numbers: E01, F51, F43

  5. Prevalence of claw disorders in Dutch dairy cows exposed to several floor systems

    NARCIS (Netherlands)

    Somers, J.G.C.J.; Frankena, K.; Noordhuizen-Stassen, E.N.; Metz, J.H.M.

    2003-01-01

    Claw health was examined in an observational study on Dutch dairy farms with either a slatted floor (SL), slatted floor with manure scraper (SL-SCR), solid concrete floor (SCF), a straw yard (SY), or a zero-grazing feeding system (ZG). Hooves of cows' hind legs were examined for the presence and

  6. The image acquisition system design of floor grinder

    Science.gov (United States)

    Wang, Yang-jiang; Liu, Wei; Liu, Hui-qin

    2018-01-01

    Based on linear CCD, high resolution image real-time acquisition system serves as designing a set of image acquisition system for floor grinder through the calculation of optical imaging system. The entire image acquisition system can collect images of ground before and after the work of the floor grinder, and the data is transmitted through the Bluetooth system to the computer and compared to realize real-time monitoring of its working condition. The system provides technical support for the design of unmanned ground grinders.

  7. Gross community production and metabolic balance in the South Pacific Gyre, using a non intrusive bio-optical method

    Directory of Open Access Journals (Sweden)

    H. Claustre

    2008-03-01

    Full Text Available The very clear waters of the South Pacific Gyre likely constitute an end-member of oligotrophic conditions which remain essentially unknown with respect to its impact on carbon fixation and exportation. We describe a non-intrusive bio-optical method to quantify the various terms of a production budget (Gross community production, community losses, net community production in this area. This method is based on the analysis of the diel cycle in Particulate Organic Carbon (POC, derived from high frequency measurements of the particle attenuation coefficient cp. We report very high integrated rates of Gross Community Production within the euphotic layer (average of 846±484 mg C m−2 d−1 for 17 stations that are far above any rates determined using incubation techniques for such areas. Furthermore we show that the daily production of POC is essentially balanced by the losses so that the system cannot be considered as net heterotrophic. Our results thus agree well with geochemical methods, but not with incubation studies based on oxygen methods. We stress to the important role of deep layers, below the euphotic layer, in contributing to carbon fixation when incident irradiance at the ocean surface is high (absence of cloud coverage. These deep layers, not considered up to know, might fuel part of the heterotrophic processes in the upper layer, including through dissolved organic carbon. We further demonstrate that, in these extremely clear and stratified waters, integrated gross community production is proportional to the POC content and surface irradiance via an efficiency index ψ GCP*, the water column cross section for Gross Community Production. We finally discuss our results in the context of the role of oligotrophic gyre in the global carbon budget and of the possibility of using optical proxies from space for the development of growth community rather than primary production

  8. Development of Claw Traits and Claw Lesions in Dairy Cows kept on different floor systems

    NARCIS (Netherlands)

    Somers, J.G.C.J.; Schouten, W.G.P.; Frankena, K.; Noordhuizen-Stassen, E.N.; Metz, J.H.M.

    2005-01-01

    Several claw shape measurements, horn hardness, and horn growth and wear were recorded monthly at 12 dairy farms to investigate the effect of floor type and changes in these traits over time. Herds were either housed on a slatted floor (SL), solid concrete floor (SC), grooved floor (GR), or on a

  9. Improvement of gross theory of beta-decay for application to nuclear data

    Science.gov (United States)

    Koura, Hiroyuki; Yoshida, Tadashi; Tachibana, Takahiro; Chiba, Satoshi

    2017-09-01

    A theoretical study of β decay and delayed neutron has been carried out with a global β-decay model, the gross theory. The gross theory is based on a consideration of the sum rule of the β-strength function, and gives reasonable results of β-decay rates and delayed neutron in the entire nuclear mass region. In a fissioning nucleus, neutrons are produced by β decay of neutron-rich fission fragments from actinides known as delayed neutrons. The average number of delayed neutrons is estimated based on the sum of the β-delayed neutron-emission probabilities multiplied by the cumulative fission yield for each nucleus. Such a behavior is important to manipulate nuclear reactors, and when we adopt some new high-burn-up reactors, properties of minor actinides will play an important roll in the system, but these data have not been sufficient. We re-analyze and improve the gross theory. For example, we considered the parity of neutrons and protons at the Fermi surface, and treat a suppression for the allowed transitions in the framework of the gross theory. By using the improved gross theory, underestimated half-lives in the neutron-rich indium isotopes and neighboring region increase, and consequently follow experimental trend. The ability of reproduction (and also prediction) of the β-decay rates, delayed-neutron emission probabilities is discussed. With this work, we have described the development of a programming code of the gross theory of β-decay including the improved parts. After preparation finished, this code can be released for the nuclear data community.

  10. Final report on the sampling and analysis of sediment cores from the L-Area oil and chemical basin

    Energy Technology Data Exchange (ETDEWEB)

    1985-08-01

    Nine vibracores were collected in the L-Area oil and chemical basin (904-83G) during late March and early April 1985. These cores were collected for analysis of the sludge on the basin floor and the underlying sediment. Several different field and laboratory analyses were performed on each three inch segment of all the cores. These included: (1) Sediment characterization; (2) Percent moisture; (3) Dry weight; (4) Spectral gamma analysis; (5) Gross alpha and beta analysis. Detailed chemical analysis were measured on selected intervals of 2 cores (LBC-5 and 6) for complete chemical characterization of the sediments. This sampling program was conducted to provide information so that a closure plan for the basin could be developed. This report describes the methods employed during the project and provide a hard copy of the analytical results from the sample analyses. Included in the appendices are copies of all field and laboratory notes taken during the project and copies of the gas chromatograms for the petroleum hydrocarbon analysis. All chemical results were also submitted on a 5-inch floppy disk.

  11. Regulatory Guide 1.122: Development of floor design response spectra for seismic design of floor-supported equipment or components

    International Nuclear Information System (INIS)

    Anon.

    1993-01-01

    ''Reactor Site Criteria,'' requires, in part, that safety-related structures, systems, and components remain functional in the event of a Safe Shutdown Earthquake (SSE). It specifies the use of a suitable dynamic analysis as one method of ensuring that the structures, systems, and components can withstand the seismic loads. Similarly, paragraph (a)(2) of Section VI of the same appendix requires, in part, that the structures, systems, and components necessary for continued operation without undue risk to the health and safety of the public remain functional in the event of an Operating Basis Earthquake (OBE). Again, the use of suitable dynamic analysis is specified as one method of ensuring that the structures, systems, and components can withstand the seismic loads. This guide describes methods acceptable to the NRC staff for developing two horizontal and one vertical floor design response spectra at various floors or other equipment-support locations of interest from the time-history motions resulting from the dynamic analysis of the supporting structure. These floor design response spectra are needed for the dynamic analysis of the systems or equipment supported at various locations of the supporting structure

  12. [Comparison of pelvic floor muscle strength in competition-level athletes and untrained women].

    Science.gov (United States)

    Ludviksdottir, Ingunn; Hardardottir, Hildur; Sigurdardottir, Thorgerdur; Ulfarsson, Gudmundur F

    2018-01-01

    Exercise can stress the pelvic floor muscles. Numerous women experience urinary incontinence while exercising or competing in sports. This study investigated pelvic floor muscle strength, urinary incontinence, and knowledge in contracting pelvic floor muscles among female athletes and untrained women. This was a prospective case-control study measuring pelvic floor muscle strength using vaginal pressure meas-urement. Participants answered questions regarding general health, urinary incontinence, and knowledge on pelvic floor muscles. Partici-pants were healthy nulliparous women aged 18-30 years, athletes and untrained women. The athletes had competed in their sport for at least three years; including handball, soccer, gymnastics, badminton, BootCamp and CrossFit. The women were comparable in age and height. The athletes (n=18) had a body mass index (BMI) of 22.8 kg/m² vs. 25 kg/m² for the untrained (n=16); p<0.05. The athletes trained on average 11.4 hours/week while the untrained women participated in some activity on average for 1.3 hours/week; p< 0.05. Mean pelvic floor strength was 45±2 hPa in the athletes vs. 43±4 hPa in the untrained; p=0.36 for whether the athletes were stronger. Of the athletes, 61.1% experienced urinary incontinence (n=11) compared with 12.5% of the untrained women (n=2); p<0.05. Incontinence usually occurred during high intensity exercise. The athletes were more knowledgeable about the pelvic floor muscles; p<0.05. There was not a significant difference in the strength of pelvic floor muscles of athletes and untrained women. This suggests that pelvic floor muscles are not strengthened during general training but require specific exercises. This holds especially for football, handball and sports with high physical intensity. Coaches need to pay special attention to training and strengthening women's pelvic floor muscles to reduce the occurrence of urinary incontinence.

  13. Effect of pelvic floor muscle exercises on pulmonary function

    OpenAIRE

    Han, DongWook; Ha, Misook

    2015-01-01

    [Purpose] This study aimed to determine the correlation between pelvic floor muscle strength and pulmonary function. In particular, we examined whether pelvic floor muscle exercises can improve pulmonary function. [Subjects] Thirty female college students aged 19?21 with no history of nervous or musculoskeletal system injury were randomly divided into experimental and control groups. [Methods] For the pulmonary function test, spirometry items included forced vital capacity and maximal volunta...

  14. Sea floor topography and backscatter intensity of the Historic Area Remediation Site (HARS), offshore of New York, based on multibeam surveys conducted in 1996, 1998, and 2000

    Science.gov (United States)

    Butman, Bradford; Danforth, W.W.; Knowles, S.C.; May, Brian; Serrett, Laurie

    2000-01-01

    An area offshore of Sandy Hook, New Jersey, has been used extensively for disposal of dredged and other materials, derived from the New York/New Jersey Harbor and surrounding areas, since the late 1800's (Figure 1). Between 1976 and 1995, the New York Bight Dredged Material Disposal Site, also known as the Mud Dump Site (Figure 2), received on average about 6 million cubic yards of material each year from federal and private maintenance dredging and from harbor deepening activities (Massa and others, 1996). In September 1997 the Mud Dump Site (MDS) was closed as an official ocean disposal site by the U.S. Environmental Protection Agency (http://www.epa.gov/), and the MDS and surrounding areas were designated as the Historic Area Remediation Site (HARS). The HARS is subdivided into a Primary Remediation Area (PRA, subdivided into 9 cells), a Buffer Zone, and a No-Discharge Zone (Figure 2). The sea floor of the HARS, approximately 9 square nautical miles in area, is being remediated by placing at least a one-meter cap of Category I (clean) dredged material on top of the existing surface sediments that exhibit varying degrees of degradation. (See http://www.nan.usace.army.mil/business/prjlinks/dmmp/benefic/hars.htm)(Category I sediments have no potential short or long-term impacts and are acceptable for unrestricted ocean disposal (EPA, 1996)). About 1.1 million cubic yards of dredged material for remediation was placed in the HARS in 1999, and 2.5 million cubic yards in 2000. Three multibeam echosounder surveys were carried out to map the topography and surficial geology of the HARS. The surveys were conducted November 23 - December 3, 1996, October 26 - November 11, 1998, and April 6 - 30, 2000. The surveys were carried out as part of a larger survey of the Hudson Shelf Valley and adjacent shelf (Butman and others, 1998, (http://pubs.usgs.gov/openfile/of98-616/). This report presents maps showing topography, shaded relief, and backscatter intensity (a measure of sea

  15. Timber floors strengthened with concrete

    NARCIS (Netherlands)

    Blass, H.J.; Linden, M.L.R. van der; Schlager, M.

    1998-01-01

    Timber-concrete composite (tcc) beams may be used for the renovation of old timber floors. Although these systems are not new (Pokulka, 1997) and form a simple and practical solution, they are not widely adopted. One of the reasons for this is the Jack of uniform design rules. In this research

  16. Timber-concrete composite floor systems

    NARCIS (Netherlands)

    Linden, M.L.R. van der; Blass, H.J.

    1996-01-01

    Timber-concrete composite (tcc) beams may be used for the renovation of old timber floors. Although these systems are a simple and practical solution, they are not widely adopted. One of the reasons for this is the lack of uniform design mies. In this research programme shear tests on four different

  17. Are gross motor skills and sports participation related in children with intellectual disabilities?

    Science.gov (United States)

    Westendorp, Marieke; Houwen, Suzanne; Hartman, Esther; Visscher, Chris

    2011-01-01

    This study compared the specific gross motor skills of 156 children with intellectual disabilities (ID) (50 ≤ IQ ≥ 79) with that of 255 typically developing children, aged 7-12 years. Additionally, the relationship between the specific gross motor skills and organized sports participation was examined in both groups. The Test of Gross Motor Development-2 and a self-report measure were used to assess children's gross motor skills and sports participation, respectively. The children with ID scored significantly lower on almost all specific motor skill items than the typically developing children. Children with mild ID scored lower on the locomotor skills than children with borderline ID. Furthermore, we found in all groups that children with higher object-control scores participated more in organized sports than children with lower object-control scores. Our results support the importance of attention for well-developed gross motor skills in children with borderline and mild ID, especially to object-control skills, which might contribute positively to their sports participation. Copyright © 2011 Elsevier Ltd. All rights reserved.

  18. Efficacy of hypopressive abdominal gymnastics in rehabilitating the pelvic floor of women: A systematic review.

    Science.gov (United States)

    Ruiz de Viñaspre Hernández, R

    2017-12-13

    Hypopressive abdominal gymnastics has been proposed as a new paradigm in rehabilitating the pelvic floor. Its claims contraindicate the recommendation for pelvic floor muscle training during the postpartum period. To determine whether hypopressive abdominal gymnastics is more effective than pelvic floor muscle training or other alternative conservative treatments for rehabilitating the pelvic floor. We consulted the databases of the Cumulative Index to Nursing and Allied Health Literature (CINAHL), the Cochrane Library, Latin American and Caribbean Health Sciences Literature (LILACS), Physiotherapy Evidence Database (PEDro), PubMed, Scopus, Trip Database and Web of Science. We selected systematic reviews, clinical trials and analytical studies that assessed the efficacy of hypopressive abdominal gymnastics in women. The measured outcomes were the strengthening of the pelvic floor muscles, the incidence of urine incontinence or prolapse and symptom remission. We included 4 clinical trials, whose quality was measured with the PEDro scale. Hypopressive gymnastics is less effective than pelvic floor muscle training for activating pelvic floor muscles, achieving closure of the levator hiatus of the anus and increasing pelvic floor muscle thickness, strength and resistance. The evidence reviewed does not support the recommendation for hypopressive abdominal gymnastics for strengthening the pelvic floor either during the postpartum period or outside that period. Pelvic floor muscle training remains the first-line treatment for pelvic floor dysfunction. There is a lack of quality clinical trials that have evaluated the efficacy of hypopressive abdominal gymnastics. Copyright © 2017 AEU. Publicado por Elsevier España, S.L.U. All rights reserved.

  19. Radiation budget, soil heat flux and latent heat flux at the forest floor in warm, temperate mixed forest

    International Nuclear Information System (INIS)

    Tamai, K.; Abe, T.; Araki, M.; Ito, H.

    1998-01-01

    Seasonal changes in the radiation budget and soil heat flux of a forest floor were measured in a mixed forest located in Kyoto, Japan. The basal area at breast height in the survey forest was about 15·82 m 2 ha −1 , for evergreen trees, and 12·46 m 2 ha −1 , for deciduous trees. The sky view factor was 16 and 22% at the survey site in the foliate and defoliate seasons, respectively. The small difference between the sky view factor in the two seasons was reflected in the seasonal change in the radiation budget of the forest floor. Namely, the net long-wave radiation changed rapidly in leafing and falling days, and the rate of net short-wave radiation was highest in April. The distinctive characteristic of the radiation budget was that the rates of available radiation in the daytime and at night were almost equal in September and October. Latent heat flux at the forest floor was estimated to be around 94 MJ m −2 annually, from our measurement with the simulation model. (author)

  20. Exposure to Radon in Dwellings in the Area of Zagreb

    International Nuclear Information System (INIS)

    Lokobauer, N.; Franic, Z.; Petroci, Lj.; Sokolovic, E.; Lokner, V.

    1998-01-01

    Until the 1970s radon and its progeny were regarded as radiation health hazards encountered only in the mining and processing of uranium ore. This notion has dramatically changed as a result of increasing efforts made by many countries to measure radon in dwellings. Since it has been assessed that radon constitutes on average about 53% of the human exposure to natural radiation (UNSCEAR 1993), attention to the problem of exposure to radon and associated health risk has been growing in both developed and developing countries. This paper deals with the investigations of indoor radon activity concentrations at selected dwellings in the area of Zagreb. The fact that concentration of indoor radon depends strongly on radium sources in the soil pointed to the possibility that increased radon levels could be measured in the ground floor dwellings. The measurements of indoor radon performed by Honeywell professional radon monitor in the 30 ground floor dwellings, and at same location in 10 dwellings on higher floors. In order to obtain average daily values, radon activity concentrations were measured throughout 24 hours at each dwelling, over the seasons spring-summer and autumn-winter. In the season spring-summer radon activity concentrations in the ground floor dwellings ranged from 22±5 to 133±12 Bqm -3 (mean value 56±31 Bqm -3 ) and in the season autumn-winter ranged from 22±5 to 311±18 Bqm -3 (mean value 94±64 Bqm -3 ). In the dwellings on higher floors radon activity concentrations in the season spring-summer ranged from 11±3 to 78±9 Bqm -3 (mean value 32±21 Bqm -3 ), and in the season autumn-winter ranged from 30±5 to 137±12 Bqm -3 (mean value 60±32 Bqm -3 ). Average annual radon activity concentration for the 30 investigated ground floor dwellings were 75±45 Bqm -3 , and 46±26 Bqm -3 for the 10 dwellings on higher floors. Investigations performed in the dwellings in the area of Zagreb revealed significant differences in radon levels between the ground

  1. Gross greenhouse gas fluxes from hydro-power reservoir compared to thermo-power plants

    International Nuclear Information System (INIS)

    Santos, Marco Aurelio dos; Pinguelli Rosa, Luiz; Sikar, Bohdan; Sikar, Elizabeth; Santos, Ednaldo Oliveira dos

    2006-01-01

    This paper presents the findings of gross carbon dioxide and methane emissions measurements in several Brazilian hydro-reservoirs, compared to thermo power generation. The term 'gross emissions' means gas flux measurements from the reservoir surface without natural pre-impoundment emissions by natural bodies such as the river channel, seasonal flooding and terrestrial ecosystems. The net emissions result from deducting pre-existing emissions by the reservoir. A power dam emits biogenic gases such as CO 2 and CH 4 . However, studies comparing gas emissions (gross emissions) from the reservoir surface with emissions by thermo-power generation technologies show that the hydro-based option presents better results in most cases analyzed. In this study, measurements were carried in the Miranda, Barra Bonita, Segredo, Tres Marias, Xingo, and Samuel and Tucurui reservoirs, located in two different climatological regimes. Additional data were used here from measurements taken at the Itaipu and Serra da Mesa reservoirs. Comparisons were also made between emissions from hydro-power plants and their thermo-based equivalents. Bearing in mind that the estimated values for hydro-power plants include emissions that are not totally anthropogenic, the hydro-power plants studied generally posted lower emissions than their equivalent thermo-based counterparts. Hydro-power complexes with greater power densities (capacity/area flooded-W/m 2 ), such as Itaipu, Xingo, Segredo and Miranda, have the best performance, well above thermo-power plants using state-of-the-art technology: combined cycle fueled by natural gas, with 50% efficiency. On the other hand, some hydro-power complexes with low-power density perform only slightly better or even worse than their thermo-power counterparts

  2. Carbon and nitrogen accumulation in forest floor and surface soil under different geographic origins of Maritime pine (Pinus pinaster Aiton. plantations

    Directory of Open Access Journals (Sweden)

    E. Ozdemir

    2013-07-01

    Full Text Available Aim of study : To determine if plantations consisting of different geographic origins of the Maritime pine (Pinus pinaster Aiton. could have altered C and N stocks in the forest floor and surface soils.Area of study : Forest floor and mineral soil C and N stocks were measured in four adjacent plantations of different geographic origins of Maritime pine (Gironde, Toulon, Corsica and Spain and adjacent primary native Sessile oak (Quercus petraea L. at Burunsuz region in Belgrad Forest where is located in the Istanbul province in the Marmara geographical region between 41°09' -41°12' N latitude and 28°54' - 29°00' E longitude in Turkey.Material and Methods : Plots were compared as common garden experiments without replications. 15 surface soil (0-10 cm and 15 forest floor samples were taken from each Maritime pine origins and adjacent native Sessile oak forest. C and N contents were determined on LECO Truspec 2000 CN analyzer. The statistical significance of the results was evaluated by one-way Analysis of Variance (ANOVA.Research highlights : Forest floor carbon mass, nitrogen concentration and nitrogen mass of forest floor showed a significant difference among origins. Soil carbon mass and nitrogen mass did not significantly differ among investigated plots.Keywords: carbon sequestration; C/N ratio; decomposition; exotic; tree provenance.

  3. Effects of maxillary sinus floor elevation surgery on maxillary sinus physiology

    NARCIS (Netherlands)

    Timmenga, NM; Raghoebar, GM; Liem, RSB; van Weissenbruch, R; Manson, WL; Vissink, A

    In a prospective study, the effects of elevation surgery of the maxillary sinus floor on maxillary sinus physiology were assessed. Seventeen consecutive patients without preoperative anamnestic, clinical and radiological signs of maxillary sinusitis underwent sinus floor elevation surgery with iliac

  4. Sea-floor morphology and sedimentary environments in western Block Island Sound, offshore of Fishers Island, New York

    Science.gov (United States)

    McMullen, Katherine Y.; Poppe, Lawrence J.; Danforth, William W.; Blackwood, Dann S.; Winner, William G.; Parker, Castle E.

    2015-01-01

    Multibeam-bathymetric and sidescan-sonar data, collected by the National Oceanic and Atmospheric Administration in a 114-square-kilometer area of Block Island Sound, southeast of Fishers Island, New York, are combined with sediment samples and bottom photography collected by the U.S. Geological Survey from 36 stations in this area in order to interpret sea-floor features and sedimentary environments. These interpretations and datasets provide base maps for studies on benthic ecology and resource management. The geologic features and sedimentary environments on the sea floor are products of the area’s glacial history and modern processes. These features include bedrock, drumlins, boulders, cobbles, large current-scoured bathymetric depressions, obstacle marks, and glaciolacustrine sediments found in high-energy sedimentary environments of erosion or nondeposition; and sand waves and megaripples in sedimentary environments characterized by coarse-grained bedload transport. Trawl marks are preserved in lower energy environments of sorting and reworking. This report releases the multibeam-bathymetric, sidescan-sonar, sediment, and photographic data and interpretations of the features and sedimentary environments in Block Island Sound, offshore Fishers Island.

  5. ϵ-expansion in the Gross-Neveu

    Energy Technology Data Exchange (ETDEWEB)

    Raju, Avinash [Center for High Energy Physics, Indian Institute of Science,Bangalore 560012 (India)

    2016-10-18

    We use the recently developed CFT techniques of Rychkov and Tan to compute anomalous dimensions in the O(N) Gross-Neveu model in d=2+ϵ dimensions. To do this, we extend the “cowpie contraction' algorithm of http://arxiv.org/abs/1506.06616 to theories with fermions. Our results match perfectly with Feynman diagram computations.

  6. The influence of body mass index and gender on the impact attenuation properties of flooring systems.

    Science.gov (United States)

    Bhan, Shivam; Levine, Iris; Laing, Andrew C

    2013-12-01

    The biomechanical effectiveness of safety floors has never been assessed during sideways falls with human volunteers. Furthermore, the influence of body mass index (BMI) and gender on the protective capacity of safety floors is unknown. The purpose of this study was to test whether safety floors provide greater impact attenuation compared with traditional flooring, and whether BMI and gender modify their impact attenuation properties. Thirty participants (7 men and 7 women of low BMI; 7 men and 9 women of high BMI) underwent lateral pelvis release trials on 2 common floors and 4 safety floors. As a group, the safety floors reduced peak force (by up to 11.7%), and increased the time to peak force (by up to 25.5%) compared with a traditional institutional grade floor. Force attenuation was significantly higher for the low BMI group, and for males. Force attenuation was greatest for the low BMI males, averaging 26.5% (SD = 3.0) across the safety floors. These findings demonstrate an overall protective effect of safety floors during lateral falls on the pelvis, but also suggest augmented benefits for frail older adults (often with low body mass) who are at an increased risk of hip fracture.

  7. The Effect of Commonly Performed Exercises on the Levator Hiatus Area and the Length and Strength of Pelvic Floor Muscles in Postpartum Women.

    Science.gov (United States)

    Siff, Lauren N; Hill, Audra J; Walters, Samantha J; Walters, Ginny; Walters, Mark D

    2018-05-02

    The aim oft his study was to compare the effects of 10 common exercises to traditional pelvic floor muscle (PFM) contractions (Kegel) on levator hiatus (LH) area and PFM length and strength. This is a cross-sectional study of 15 healthy postpartum women. Ten exercises were studied. These were common variations of leg, core, and back exercises used in yoga, Pilates, strength training, and physical therapy. Each participant performed all 10 exercises at a single visit in 2 examination settings: transperineal ultrasound and perineometry. Ultrasound measured the LH area and PFM length, and perineometry measured the muscle strength (peak squeeze pressure). Kegel generates an increase in squeeze pressure (24.3 cm H2O), shortens the muscles (-0.46 cm) and narrows the LH (-0.13 cm). The bird-dog and plank exercises were not different from Kegel in any measurement. While the leg-lift ultrasound dimensions are similar to Kegel, leg lifts generated peak squeeze pressures stronger than any other exercise (including Kegel). Whereas ultrasound dimensions were similar to Kegel, tucked and untucked squats and thigh adductions generated weaker contractions than Kegel. While crunch generated a squeeze pressure similar to Kegel, the ultrasound dimensions showed a significantly wider LH and longer muscle than Kegel. Bridge, clam, and plié exercises affected the PFMs differently than Kegel in all measures. Bird-dog, plank, and leg-lift exercises should be evaluated as alternative exercises to Kegel as they affect PFM strength and length and LH area similarly to Kegel, and leg lifts generate a stronger contraction than Kegel.

  8. Summarized report of geothermal well Gross Buchholz Gt1; Kurzprofil der Geothermiebohrung Gross Buchholz Gt1

    Energy Technology Data Exchange (ETDEWEB)

    Schaefer, Frauke; Hesshaus, Annalena; Jatho, Reiner; Luppold, Friedrich-Wilhelm; Pletsch, Thomas; Tischner, Torsten [Bundesanstalt fuer Geowissenschaften und Rohstoffe (BGR), Hannover (Germany); Hunze, Sabine; Orilski, Judith; Wonik, Thomas [Leibniz-Institut fuer Angewandte Geophysik (LIAG), Hannover (Germany); Roehling, Heinz-Gerd [Landesamt fuer Bergbau, Energie und Geologie (LBEG), Hannover (Germany)

    2012-01-15

    The well Gross Buchholz Gt1 is a deep geothermal well intended to demonstrate the feasibility of deep geothermal energy mining from tight sedimentary rocks. It is the core part of the GeneSys (Generated Geothermal Energy Systems) project, aiming at developing single well concepts for direct use of geothermal energy. During the course of the project, three different single well concepts have been developed and tested at the research well Horstberg Z1 which is geologically comparable to the Gross Buchholzwell. The latter is intended to supply the heating energy for the premises of Geozentrum Hannover, an office and lab complex of some 35.000 m{sup 2} housing about 1000 employees. The geothermal target are the sandstones of the Lower Triassic Middle Buntsandstein Formation, which have a temperature of about 165 C at 3700 depth. The well has reached a final depth of 3901 m below ground level, penetrating a nearly complete succession from the Lower Cretaceous (Albian) to the Lower Triassic (Lower Buntsandstein), while Tertiary and Upper Cretaceous sediments are missing. This article summarizes technical and geographic data, stratigraphic classification, geophysical logging, cores, and sidewall cores of the well. (orig.)

  9. The Combine Use of Semi-destructive and Non-destructive Methods for Tiled Floor Diagnostics

    Science.gov (United States)

    Štainbruch, Jakub; Bayer, Karol; Jiroušek, Tomáš; Červinka, Josef

    2017-04-01

    -destructive resistivity drilling, and non-destructive georadar, and the results were compared. Floors were measured by 3D laser scanning technology and captured by the camera before reconstruction work. Using SFM photogrammetry were achieved results: ortomozaik (0.3 mm / pix) and DEM (0.6 mm / pix). These results were a basis for restoration work and also allow comparisons with the original state at any stage of the project. Drilling resistance measurement is used for indirect determination of strength profile based on resistance to drilling depending on into the depth. The observed resistance to drilling correlates with the strength and toughness of the measured material. The method is referred as a micro- or semi-invasive, since sampling is not necessary and but the drilling diameter is usually 3-5 mm. The ultrasonic measurement consists in the measuring of the longitude as well as the transverse waves - velocity, shape, amplitude. The propagation velocity is a characteristic values for the material influenced by its composition and compactness. Georadar (GPR) is a high frequency electromagnetic pulse method. For measurement the GPR RAMAC system coupled with 1600 MHz shielded antenna was used. Two tiles (one with defects and one in relatively good condition) were surveyed in a regular grid of perpendicular lines 5 cm separated. Data were processed by means of ReflexW software and performed in the form of cross sections and amplitude maps. The map of the amplitude summed over a time window 1 - 1,4 ns (representing the intensity of the reflection from the tiles bottom) gave good result. The areas of registered relatively high amplitudes correspond with the position of airgaps. A correlation was observed between the results of different survey methods.

  10. Gross Revenue risk in Swiss dairy farming

    NARCIS (Netherlands)

    Benni, El N.; Finger, R.

    2013-01-01

    This study investigated how agricultural policy reforms, including market liberalization and market deregulation, have influenced gross revenue risk of Swiss dairy producers using farm-level panel data between 1990 and 2009. Based on detrended data, variance decomposition was applied to assess how

  11. Detection and mapping of shipwrecks embedded in sea-floor sediments

    DEFF Research Database (Denmark)

    Grøn, O.; Boldreel, Lars Ole; Cvikel, D.

    2015-01-01

    different geographical and geological areas and from different periods. The effects of shallow water depths, different sediment types, recording speed and different (2D and 3D) sub-bottom profiler systems are briefly discussed. It is concluded that Chirps are well suited for survey purposes, producing high...... quality 2D profiles of good resolution and satisfactory penetration depth. Furthermore, the equipment is easy to handle from a small boat and allows flexible sailing. This type of 2D data is cheaper and faster to acquire and is easier to interpret and apparently also provides better resolution and detail...... than present 3D systems. Chirp data are therefore of great value in identifying and outlining shipwrecks hidden in the sea floor in survey situations where larger areas must be covered. The overall conclusion is that there are grounds for optimism with regard to this method of detection of maritime...

  12. 76 FR 76690 - Multilayered Wood Flooring From the People's Republic of China: Amended Final Determination of...

    Science.gov (United States)

    2011-12-08

    ... construction or locking joints). All multilayered wood flooring is included within the definition of the... DEPARTMENT OF COMMERCE International Trade Administration [A-570-970] Multilayered Wood Flooring... is issuing an antidumping duty order on multilayered wood flooring (``wood flooring'') from the...

  13. A variational approach to the Gross-Neveu model

    International Nuclear Information System (INIS)

    Mishra, H.; Misra, P.; Mishra, A.

    1988-01-01

    The authors solve the instability of perturbative vacuum of Gross-Neveu model. They use a variational method. The analysis is nonperturbative as it uses only equal time commmutator/anticommutator algebra

  14. Friction between footwear and floor covered with solid particles under dry and wet conditions.

    Science.gov (United States)

    Li, Kai Way; Meng, Fanxing; Zhang, Wei

    2014-01-01

    Solid particles on the floor, both dry and wet, are common but their effects on the friction on the floor were seldom discussed in the literature. In this study, friction measurements were conducted to test the effects of particle size of solid contaminants on the friction coefficient on the floor under footwear, floor, and surface conditions. The results supported the hypothesis that particle size of solids affected the friction coefficient and the effects depended on footwear, floor, and surface conditions. On dry surfaces, solid particles resulted in friction loss when the Neolite footwear pad was used. On the other hand, solid particles provided additional friction when measured with the ethylene vinyl acetate (EVA) footwear pad. On wet surfaces, introducing solid particles made the floors more slip-resistant and such effects depended on particle size. This study provides information for better understanding of the mechanism of slipping when solid contaminants are present.

  15. Analytical model and application of stress distribution on mining coal floor

    Institute of Scientific and Technical Information of China (English)

    ZHU Shu-yun; JIAN Zhen-quan; HOU Hong-liang; XIAO Wei-guo; YAO Pu

    2008-01-01

    Given the analysis of underground pressure, a stress calculation model of coal floor stress has been established based on a theory of elasticity. The model presents the law of stress distribution on the relatively fixed position of the mining coal floor: the extent of stress variation in a fixed floor position decreases gradually along with depth, the decreasing rate of the vertical stress is clearly larger than that of the horizontal stress at a specific depth. The direction of the maximum principal stress changes gradually from a vertical direction to a horizontal direction with the advance of the working face. The deformation and permeability of the rock mass of the coal floor are obtained by contrasting the difference of the principal stress established from theoretical calculations with curves of stress-strain and permeability-strain from tests, which is an important mechanical basis for preventing water inrush from confined aquifers.

  16. Assessing the ability of MODIS EVI to estimate terrestrial ecosystem gross primary production of multiple land cover types

    Czech Academy of Sciences Publication Activity Database

    Shi, H.; Li, L.; Eamus, D.; Huete, A.; Cleverly, J.; Tian, X.; Yu, Q.; Wang, S.; Montagnani, L.; Magliulo, V.; Rotenberg, E.; Pavelka, Marian; Carrara, A.

    2017-01-01

    Roč. 72, Jan (2017), s. 153-164 ISSN 1470-160X R&D Projects: GA MŠk(CZ) LM2015061 Institutional support: RVO:67179843 Keywords : Enhanced vegetation index * Gross primary production * Land cover types * Leaf area index * MODIS * Remote sensing Subject RIV: EH - Ecology, Behaviour OBOR OECD: Environmental sciences (social aspects to be 5.7) Impact factor: 3.898, year: 2016

  17. Is Pelvic Floor Muscle Training Effective for Men With Poststroke Lower Urinary Tract Symptoms?

    DEFF Research Database (Denmark)

    Tibaek, Sigrid; Gard, Gunvor; Dehlendorff, Christian

    2017-01-01

    The aim of the current study was to evaluate the effect of pelvic floor muscle training in men with poststroke lower urinary tract symptoms. Thirty-one poststroke men, median age 68 years, were included in this single-blinded randomized controlled trial. Thirty participants, 15 in each group......, completed the study. The intervention consisted of 3 months (12 weekly sessions) of pelvic floor muscle training in groups and home exercises. The effect was evaluated by the DAN-PSS-1 (Danish Prostate Symptom Score) questionnaire, a voiding diary, and digital anal palpation of the pelvic floor muscle...... that pelvic floor muscle training has an effect for lower urinary tract symptoms, although statistical significance was only seen for pelvic floor muscle....

  18. Ethics, economics and the regulation and adoption of new medical devices: case studies in pelvic floor surgery

    Science.gov (United States)

    2010-01-01

    Background Concern has been growing in the academic literature and popular media about the licensing, introduction and adoption of surgical devices before full effectiveness and safety evidence is available to inform clinical practice. Our research will seek empirical survey evidence about the roles, responsibilities, and information and policy needs of the key stakeholders in the introduction into clinical practice of new surgical devices for pelvic floor surgery, in terms of the underlying ethical principals involved in the economic decision-making process, using the example of pelvic floor procedures. Methods/Design Our study involves three linked case studies using, as examples, selected pelvic floor surgery devices representing Health Canada device safety risk classes: low, medium and high risk. Data collection will focus on stakeholder roles and responsibilities, information and policy needs, and perceptions of those of other key stakeholders, in seeking and using evidence about new surgical devices when licensing and adopting them into practice. For each class of device, interviews will be used to seek the opinions of stakeholders. The following stakeholders and ethical and economic principles provide the theoretical framework for the study: Stakeholders - federal regulatory body, device manufacturers, clinicians, patients, health care institutions, provincial health departments, and professional societies. Clinical settings in two centres (in different provinces) will be included. Ethics - beneficence, non-maleficence, autonomy, justice. Economics - scarcity of resources, choices, opportunity costs. For each class of device, responses will be analysed to compare and contrast between stakeholders. Applied ethics and economic theory, analysis and critical interpretation will be used to further illuminate the case study material. Discussion The significance of our research in this new area of ethics will lie in providing recommendations for regulatory bodies

  19. Ethics, economics and the regulation and adoption of new medical devices: case studies in pelvic floor surgery

    Directory of Open Access Journals (Sweden)

    Ross Sue

    2010-08-01

    Full Text Available Abstract Background Concern has been growing in the academic literature and popular media about the licensing, introduction and adoption of surgical devices before full effectiveness and safety evidence is available to inform clinical practice. Our research will seek empirical survey evidence about the roles, responsibilities, and information and policy needs of the key stakeholders in the introduction into clinical practice of new surgical devices for pelvic floor surgery, in terms of the underlying ethical principals involved in the economic decision-making process, using the example of pelvic floor procedures. Methods/Design Our study involves three linked case studies using, as examples, selected pelvic floor surgery devices representing Health Canada device safety risk classes: low, medium and high risk. Data collection will focus on stakeholder roles and responsibilities, information and policy needs, and perceptions of those of other key stakeholders, in seeking and using evidence about new surgical devices when licensing and adopting them into practice. For each class of device, interviews will be used to seek the opinions of stakeholders. The following stakeholders and ethical and economic principles provide the theoretical framework for the study: Stakeholders - federal regulatory body, device manufacturers, clinicians, patients, health care institutions, provincial health departments, and professional societies. Clinical settings in two centres (in different provinces will be included. Ethics - beneficence, non-maleficence, autonomy, justice. Economics - scarcity of resources, choices, opportunity costs. For each class of device, responses will be analysed to compare and contrast between stakeholders. Applied ethics and economic theory, analysis and critical interpretation will be used to further illuminate the case study material. Discussion The significance of our research in this new area of ethics will lie in providing

  20. Pelvic Floor Muscle Training: Underutilization in the USA.

    Science.gov (United States)

    Lamin, Eliza; Parrillo, Lisa M; Newman, Diane K; Smith, Ariana L

    2016-02-01

    Pelvic floor disorders are highly prevalent in women of all ages and can greatly impair quality of life. Pelvic floor muscle training (PFMT) is a viable treatment option for several pelvic floor conditions including urinary incontinence and pelvic organ prolapse. PFMT is a program of therapy initiated by an experienced clinician (e.g., women's health or urology nurse practitioner (NP), physical therapist (PT)) that involves exercises for women with stress urinary incontinence (UI) and exercises combined with behavioral or conservative treatments (lifestyle changes, bladder training with urge suppression) for women with urgency or mixed UI. These exercise programs are more comprehensive than simple Kegel exercises. Despite evidence-based research indicating the efficacy and cost-effectiveness for treatment of urinary incontinence, PFMT is not commonly used as a first-line treatment in clinical practice in the USA (Abrams et al., 2012). This article will review PFMT for the treatment of UI and pelvic organ prolapse (POP) and theorize how this conservative therapy can be utilized more effectively in the USA.

  1. Maxillary sinus floor elevation surgery - A clinical, radiographic and endoscopic evaluation

    NARCIS (Netherlands)

    Timmenga, NM; Raghoebar, GM; van Weissenbruch, R; Vissink, A

    Although augmentation of the maxillary sinus floor with autogenous bone grafts has become a well established preimplantology procedure, its effect on the function of the maxillary sinus has not been the subject of prospective human studies. In this prospective study the effects of sinus floor

  2. Crack resistance increasing in epoxide-rubber coatings of NPP room floors

    International Nuclear Information System (INIS)

    Khorenzhenko, V.I.

    1986-01-01

    Problems of crack resistance increasing in epoxide-rubber coatings for the floors are considered. Exploitation experience of the floors in the special rooms of NPP is given. Perspectivity of application of the compositions described as the building materials for nuclear power stations is pointed out

  3. Reconstruction of Orbital Floor With Auricular Concha.

    Science.gov (United States)

    Seven, Ergin; Tellioglu, Ali Teoman; Inozu, Emre; Ozakpinar, Hulda Rifat; Horoz, Ugur; Eryilmaz, Avni Tolga; Karamursel, Sebat

    2017-10-01

    Orbital floor fractures of varying sizes commonly occur after orbital injuries and remain a serious challenge. Serious complications of such fractures include enopthalmos, restriction of extraocular movement, and diplopia. There is a dearth of literature that can be applied widely, easily, and successfully in all such situations, and therefore there is no consensus on the treatment protocol of this pathology yet. Autogenous grafts and alloplastic and allogenic materials with a wide variety of advantages and disadvantages have been discussed. The value of preoperative and postoperative ophthalmological examination should be standard of care in all orbital fracture patients. An ideal reconstructed orbital floor fracture should accelerate the restoration of orbital function with acceptable cosmetic results. Management parameters of orbital fractures such as timing of surgery, incision type, and implant materials, though widely discussed, remain controversial. In this study, 55 patients with orbital floor fractures surgically reconstructed with conchal cartilage grafts between 2008 and 2014 were retrospectively evaluated. Complications and long-time follow-up visit results have been reported with clinical and radiographic findings. The aim of this study was to present the authors' clinical experiences of reconstruction of blow-out fractures with auricular conchal graft and to evaluate the other materials available for use.

  4. Pilot cluster randomised controlled trial of flooring to reduce injuries from falls in wards for older people.

    Science.gov (United States)

    Drahota, Amy Kim; Ward, Derek; Udell, Julie E; Soilemezi, Dia; Ogollah, Reuben; Higgins, Bernard; Dean, Taraneh P; Severs, Martin

    2013-09-01

    falls disproportionately affect older people, who are at increased risk of falls and injury. This pilot study investigates shock-absorbing flooring for fall-related injuries in wards for frail older people. we conducted a non-blinded cluster randomised trial in eight hospitals in England between April 2010 and August 2011. Each site allocated one bay as the 'study area', which was randomised via computer to intervention (8.3-mm thick Tarkett Omnisports EXCEL) or control (2-mm standard in situ flooring). Sites had an intervention period of 1 year. Anybody admitted to the study area was eligible. The primary outcome was the fall-related injury rate. Secondary outcomes were injury severity, fall rate and adverse events. during the intervention period, 226 participants were recruited to each group (219 and 223 were analysed in the intervention and control group, respectively). Of 35 falls (31 fallers) in the intervention group, 22.9% were injurious, compared with 42.4% of 33 falls (22 fallers) in the control group [injury incident rate ratio (IRR) = 0.58, 95% CI = 0.18-1.91]. There were no moderate or major injuries in the intervention group and six in the control group. The fall IRR was 1.07 (95% CI = 0.64-1.81). Staff at intervention sites raised concerns about pushing equipment, documenting one pulled back. future research should assess shock-absorbing flooring with better 'push/pull' properties and explore increased faller risk. We estimate a future trial will need 33,480-52,840 person bed-days per arm.

  5. Maple Flooring - How Architects View it

    Science.gov (United States)

    Gary R. Lindell

    1971-01-01

    In a study of architects'' opinions of maple flooring versus vinyl asbestos tile for school gymnasuims, resiliency and durability were found to be important factors favoring maple whereas vinyl asbestos tile was felt to be less costly and more dimesionally stable.

  6. Effect of rearing factors on the prevalence of floor eggs, cloacal cannibalism and feather pecking in commercial flocks of loose housed laying hens.

    Science.gov (United States)

    Gunnarsson, S; Keeling, L J; Svedberg, J

    1999-03-01

    1. Effects of rearing conditions on behavioural problems were investigated in a cohort study of commercial flocks of laying hens housed in 2 different loose housing systems. The sample population was 120 385 laying hens from 59 flocks of various hybrids at 21 different farms. 2. Logistic regression modelling was used to test the effects of selected factors on floor eggs, cloacal cannibalism and feather pecking. In addition to early access to perches or litter, models included hybrid, stocking density, group size, housing system, age at delivery, identical housing system at the rearing farm and at the production farm and, in models for floor eggs and cloacal cannibalism, nest area per hen. Odds ratios were calculated from the results of the models to allow risk assessment. 3. No significant correlations were found between the prevalence of floor eggs, cloacal cannibalism and feather pecking. 4. Access to perches from not later than the 4th week of age decreased the prevalence of floor eggs during the period from start-of-lay until 35 weeks of age, odds ratio 0-30 (Pfeather pecking.

  7. Effects of land use change on soil gross nitrogen transformation rates in subtropical acid soils of Southwest China.

    Science.gov (United States)

    Xu, Yongbo; Xu, Zhihong

    2015-07-01

    Land use change affects soil gross nitrogen (N) transformations, but such information is particularly lacking under subtropical conditions. A study was carried out to investigate the potential gross N transformation rates in forest and agricultural (converted from the forest) soils in subtropical China. The simultaneously occurring gross N transformations in soil were quantified by a (15)N tracing study under aerobic conditions. The results showed that change of land use types substantially altered most gross N transformation rates. The gross ammonification and nitrification rates were significantly higher in the agricultural soils than in the forest soils, while the reverse was true for the gross N immobilization rates. The higher total carbon (C) concentrations and C / N ratio in the forest soils relative to the agricultural soils were related to the greater gross N immobilization rates in the forest soils. The lower gross ammonification combined with negligible gross nitrification rates, but much higher gross N immobilization rates in the forest soils than in the agricultural soils suggest that this may be a mechanism to effectively conserve available mineral N in the forest soils through increasing microbial biomass N, the relatively labile organic N. The greater gross nitrification rates and lower gross N immobilization rates in the agricultural soils suggest that conversion of forests to agricultural soils may exert more negative effects on the environment by N loss through NO3 (-) leaching or denitrification (when conditions for denitrification exist).

  8. Pelvic Floor Physical Therapy as Primary Treatment of Pelvic Floor Disorders With Urinary Urgency and Frequency-Predominant Symptoms.

    Science.gov (United States)

    Adams, Sonia R; Dessie, Sybil G; Dodge, Laura E; Mckinney, Jessica L; Hacker, Michele R; Elkadry, Eman A

    2015-01-01

    To assess the efficacy of pelvic floor physical therapy (PFPT) as primary treatment of urinary urgency and frequency symptoms We conducted a prospective cohort study of women with urinary urgency and frequency symptoms. Participants underwent PFPT once or twice per week for 10 weeks. Symptom improvement was assessed by validated questionnaires (Pelvic Floor Distress Inventory-Short Form 20 and Patient Global Impression of Improvement), voiding diaries, and subjective measures. Fifty-seven participants enrolled; 21 (36.8%) withdrew or completed less than 5 weeks of PFPT. Thirty-one (54.4%) of the remaining 36 participants completed 10 weeks of PFPT. The mean age of the study group (n = 36) was 48.9 ± 15.0 years. The primary diagnoses were overactive bladder syndrome (n = 24, 66.7%) and painful bladder syndrome (n = 12, 33.3%). Women attended a median of 14.0 (interquartile range [IQR], 8.0-16.0) PFPT visits over a median of 11.9 weeks (IQR, 10.0-18.1). At baseline, the median Pelvic Floor Distress Inventory-Short Form 20 score was 79.2 (IQR, 53.1-122.9), and decreased to 50.0 (IQR, 25.0-88.5; P therapies. The high dropout rates suggest that motivation or logistic factors may play a significant role in the utilization and success of this treatment option.

  9. Pelvic floor muscle problems mediate sexual problems in young adult rape victims.

    Science.gov (United States)

    Postma, Riemke; Bicanic, Iva; van der Vaart, Huub; Laan, Ellen

    2013-08-01

    Prior studies have addressed sexual abuse and sexual function in adult women. No studies have focused on the effect of adolescence rape on sexual functioning. To investigate the effect of rape on sexual problems and on pelvic floor problems, as well as the mediating role of pelvic floor problems on sexual problems, in a homogenous group of victims of adolescence rape without a history of childhood sexual, physical, and/or emotional abuse. Sexual functioning and pelvic floor functioning were assessed using self-report questionnaires. In this cross-sectional study, a group of 89 young women aged 18-25 years who were victimized by rape in adolescence was compared with a group of 114 nonvictimized controls. The rape victims were treated for posttraumatic stress disorder (PTSD) 3 years prior to participation in the study. Three years posttreatment, rape victims were 2.4 times more likely to have a sexual dysfunction (lubrication problems and pain) and 2.7 times more likely to have pelvic floor dysfunction (symptoms of provoked vulvodynia, general stress, lower urinary tract, and irritable bowel syndrome) than nonvictimized controls. The relationship between rape and sexual problems was partially mediated by the presence of pelvic floor problems. Rape victims and controls did not differ with regard to sexual activities. Rape victims suffer significantly more from sexual dysfunction and pelvic floor dysfunction when compared with nontraumatized controls, despite the provision of treatment for PTSD. Possibly, physical manifestations of PTSD have been left unaddressed in treatment. Future treatment protocols should consider incorporating (physical or psychological) treatment strategies for sexual dysfunction and/or pelvic floor dysfunction into trauma exposure treatments. © 2013 International Society for Sexual Medicine.

  10. Architectural design of the pelvic floor is consistent with muscle functional subspecialization.

    Science.gov (United States)

    Tuttle, Lori J; Nguyen, Olivia T; Cook, Mark S; Alperin, Marianna; Shah, Sameer B; Ward, Samuel R; Lieber, Richard L

    2014-02-01

    Skeletal muscle architecture is the strongest predictor of a muscle's functional capacity. The purpose of this study was to define the architectural properties of the deep muscles of the female pelvic floor (PFMs) to elucidate their structure-function relationships. PFMs coccygeus (C), iliococcygeus (IC), and pubovisceral (PV) were harvested en bloc from ten fixed human cadavers (mean age 85 years, range 55-102). Fundamental architectural parameters of skeletal muscles [physiological cross-sectional area (PCSA), normalized fiber length, and sarcomere length (L(s))] were determined using validated methods. PCSA predicts muscle-force production, and normalized fiber length is related to muscle excursion. These parameters were compared using repeated measures analysis of variance (ANOVA) with post hoc t tests, as appropriate. Significance was set to α = 0.05. PFMs were thinner than expected based on data reported from imaging studies and in vivo palpation. Significant differences in fiber length were observed across PFMs: C = 5.29 ± 0.32 cm, IC = 7.55 ± 0.46 cm, PV = 10.45 ± 0.67 cm (p design shows individual muscles demonstrating differential architecture, corresponding to specialized function in the pelvic floor.

  11. Contribution of pelvic floor muscles to stiffness of the pelvic ring

    NARCIS (Netherlands)

    Pool-Goudzwaard, A.L.; Hoek van Dijke, G; van Gurp, M; Mulder, P; Snijders, C.J.; Stoeckart, R.

    2004-01-01

    STUDY DESIGN: A biomechanical study in embalmed specimens, on the relation between applied tension in the pelvic floor muscles, stiffness of the pelvic ring and generation of movement in the sacroiliac joints. OBJECTIVE: To gain insight into the effect of tension in the pelvic floor muscles on

  12. Statistical Analysis Of Tank 19F Floor Sample Results

    International Nuclear Information System (INIS)

    Harris, S.

    2010-01-01

    Representative sampling has been completed for characterization of the residual material on the floor of Tank 19F as per the statistical sampling plan developed by Harris and Shine. Samples from eight locations have been obtained from the tank floor and two of the samples were archived as a contingency. Six samples, referred to in this report as the current scrape samples, have been submitted to and analyzed by SRNL. This report contains the statistical analysis of the floor sample analytical results to determine if further data are needed to reduce uncertainty. Included are comparisons with the prior Mantis samples results to determine if they can be pooled with the current scrape samples to estimate the upper 95% confidence limits (UCL95%) for concentration. Statistical analysis revealed that the Mantis and current scrape sample results are not compatible. Therefore, the Mantis sample results were not used to support the quantification of analytes in the residual material. Significant spatial variability among the current scrape sample results was not found. Constituent concentrations were similar between the North and South hemispheres as well as between the inner and outer regions of the tank floor. The current scrape sample results from all six samples fall within their 3-sigma limits. In view of the results from numerous statistical tests, the data were pooled from all six current scrape samples. As such, an adequate sample size was provided for quantification of the residual material on the floor of Tank 19F. The uncertainty is quantified in this report by an UCL95% on each analyte concentration. The uncertainty in analyte concentration was calculated as a function of the number of samples, the average, and the standard deviation of the analytical results. The UCL95% was based entirely on the six current scrape sample results (each averaged across three analytical determinations).

  13. 26 CFR 1.924(a)-1T - Temporary regulations; definition of foreign trading gross receipts.

    Science.gov (United States)

    2010-04-01

    ... trading gross receipts. 1.924(a)-1T Section 1.924(a)-1T Internal Revenue INTERNAL REVENUE SERVICE... United States § 1.924(a)-1T Temporary regulations; definition of foreign trading gross receipts. (a) In general. The term “foreign trading gross receipts” means any of the five amounts described in paragraphs...

  14. Gross-Motor Skill Acquisition by Preschool Dance Students under Self-Instruction Procedures

    Science.gov (United States)

    Vintere, Parsla; Hemmes, Nancy S.; Brown, Bruce L.; Poulson, Claire L.

    2004-01-01

    The effects of two training procedures -- (a) modeling and praise and (b) self-instruction, modeling, and praise -- on complex gross-motor chain acquisition for preschool dance class students were evaluated. Six girls participated in the study. A multiple baseline design across six gross-motor chains with a secondary group comparison for treatment…

  15. Does Flooring Substrate Impact Kennel and Dog Cleanliness in Commercial Breeding Facilities?

    Science.gov (United States)

    Stella, Judith; Hurt, Moriah; Bauer, Amy; Croney, Candace

    2018-01-01

    Simple Summary It is important to understand how the flooring substrate used in dog housing impacts dog health and well-being. Aspects to consider include paw, elbow, and hock health, the cleanliness of the dog, and the ability of the floors to be cleaned easily and thoroughly. This pilot study assessed the health and cleanliness of 118 dogs housed on three different types of flooring commonly found in commercial breeding kennels. No serious paw, elbow, or hock problems were identified. Thirty-one percent or fewer kennels at each facility were found to have fecal contamination after routine cleaning and the majority of dogs were clean. These findings indicate that a well-managed kennel can maintain clean, healthy dogs on different types of flooring substrates. Abstract Evaluation of kennel flooring surfaces is needed to understand their impacts on dog health and well-being. This pilot study aimed to characterize aspects of physical health, kennel cleanliness, and dog body cleanliness on flooring types common in US breeding kennels. Subjects were 118 adult dogs housed on diamond-coated expanded metal (DCEM), polypropylene (POLY), or concrete (CON) flooring at five commercial breeding facilities in Indiana, U.S. Body condition, paw, elbow, and hock health scores were recorded. Each indoor kennel and dog was visually assessed for cleanliness. Kennels were swabbed immediately after cleaning with electrostatic dry cloths and cultured for Escherichia coli. Descriptive statistics were used for analysis. Mean body condition score (BCS), kennel and dog cleanliness scores were all near ideal (3, 1.15, and 1.04, respectively). Thirty-one percent or fewer kennels at each facility were culture-positive for E. coli after cleaning. No serious paw, elbow, or hock problems were identified. Overall, the findings indicate that with appropriate management and regular access to additional surfaces, dog foot health, cleanliness, and kennel cleanliness can be maintained on the flooring

  16. Measurement of gross alpha and beta in air filter samples by using liquid scintillation counter

    International Nuclear Information System (INIS)

    Sudheendran, V.; Baburajan, A.; Gaikwad, R.H.; Ravi, P.M.; Tripathi, R.M.

    2015-01-01

    The determination of gross alpha and gross beta in particulate air filter samples was carried out by alpha, beta discrimination method using Liquid Scintillation Analyzer by setting the PSA value at 55 for 5 ml 0.1 HCl plus 15 ml of Ultima Gold AB cocktail by using 241 Am and 90 Sr/ 90 Y sources. The standardized method was compared with the gross alpha and gross beta activity determined by conventional method of direct counting with end window G.M. counter and ZnS (Ag). The minimum detectable activity of LSA method was found to be 9.3 mBq and 17.7 mBq for gross alpha and gross beta respectively for 6000 sec compared to the conventional method of 9.8 mBq and 189 mBq respectively at the same counting time. The result of analysis by both method indicate that the alpha, beta discrimination set up of LSA method is highly effective in the determination of low level alpha, beta activity in air filter samples. (author)

  17. Assessment of the radiological protection aspects of disposal of high level waste on the ocean floor

    International Nuclear Information System (INIS)

    Grimwood, P.D.; Webb, G.A.M.

    1976-10-01

    This study is a preliminary assessment of the potential radiological consequences of disposal of solidified high-level radioactive waste on the floor of the deep ocean. As an input to the modelling used in the assessment, an arbitrary choice is made to consider the total high-level waste which would be generated by a postulated world nuclear power programme to the year 2000. It is assumed that all this waste, in solidified form, is disposed of on to the floor of the North Atlantic. The body of this report is the modelling of the subsequent release of activity into the water, its dispersion in the ocean and eventual uptake in marine organisms and sediments. The consequent radiation exposure of man is assessed in terms of both individual and collective doses. It is intended that only broad conclusions should be drawn from this study. The objective of the assessment is to highlight those subject areas where more study of information is required before a decision can be reached regarding this method of disposal. No overriding reason connected with the radiological protection considerations has been identified which would preclude the disposal of suitably conditioned high-level waste on the ocean floor. Further evaluation of this disposal option is therefore justified. (author)

  18. Flooring for Schools: Unsightly Walkways

    Science.gov (United States)

    Baxter, Mark

    2011-01-01

    Many mattress manufacturers recommend that consumers rotate their mattresses at least twice a year to help prevent soft spots from developing and increase the product's life span. It's unfortunate that the same kind of treatment can't be applied to flooring for schools, such as carpeting, especially in hallways. Being able to flip or turn a carpet…

  19. 26 CFR 1.613-4 - Gross income from the property in the case of minerals other than oil and gas.

    Science.gov (United States)

    2010-04-01

    .... (7) Rate of return on investment method. [Reserved] (e) Reductions of sales price in computing gross... production of coke, all bituminous coals in the same marketing area will be considered to be of like kind... this paragraph shall attach to his return a summary statement indicating the prices used by him in...

  20. Bioelectrical activity of the pelvic floor muscles after 6-week biofeedback training in nulliparous continent women.

    Science.gov (United States)

    Chmielewska, Daria; Stania, Magdalena; Smykla, Agnieszka; Kwaśna, Krystyna; Błaszczak, Edward; Sobota, Grzegorz; Skrzypulec-Plinta, Violetta

    2016-01-01

    The aim of the study was to evaluate the effects of a 6-week sEMG-biofeedback-assisted pelvic floor muscle training program on pelvic floor muscle activity in young continent women. Pelvic floor muscle activity was recorded using a vaginal probe during five experimental trials. Biofeedback training was continued for 6 weeks, 3 times a week. Muscle strenghtening and endurance exercises were performed alternately. SEMG (surface electromyography) measurements were recorded on four different occasions: before training started, after the third week of training, after the sixth week of training, and one month after training ended. A 6-week sEMG-biofeedback-assisted pelvic floor muscle training program significantly decreased the resting activity of the pelvic floor muscles in supine lying and standing. The ability to relax the pelvic floor muscles after a sustained 60-second contraction improved significantly after the 6-week training in both positions. SEMG-biofeedback training program did not seem to affect the activity of the pelvic floor muscles or muscle fatigue during voluntary pelvic floor muscle contractions. SEMG-biofeedback-assisted pelvic floor muscle training might be recommended for physiotherapists to improve the effectiveness of their relaxation techniques.

  1. Physical activity and the pelvic floor.

    Science.gov (United States)

    Nygaard, Ingrid E; Shaw, Janet M

    2016-02-01

    Pelvic floor disorders are common, with 1 in 4 US women reporting moderate to severe symptoms of urinary incontinence, pelvic organ prolapse, or fecal incontinence. Given the high societal burden of these disorders, identifying potentially modifiable risk factors is crucial. Physical activity is one such potentially modifiable risk factor; the large number of girls and women participating in sport and strenuous training regimens increases the need to understand associated risks and benefits of these exposures. The aim of this review was to summarize studies reporting the association between physical activity and pelvic floor disorders. Most studies are cross-sectional and most include small numbers of participants. The primary findings of this review include that urinary incontinence during exercise is common and is more prevalent in women during high-impact sports. Mild to moderate physical activity, such as brisk walking, decreases both the odds of having and the risk of developing urinary incontinence. In older women, mild to moderate activity also decreases the odds of having fecal incontinence; however, young women participating in high-intensity activity are more likely to report anal incontinence than less active women. Scant data suggest that in middle-aged women, lifetime physical activity increases the odds of stress urinary incontinence slightly and does not increase the odds of pelvic organ prolapse. Women undergoing surgery for pelvic organ prolapse are more likely to report a history of heavy work than controls; however, women recruited from the community with pelvic organ prolapse on examination report similar lifetime levels of strenuous activity as women without this examination finding. Data are insufficient to determine whether strenuous activity while young predisposes to pelvic floor disorders later in life. The existing literature suggests that most physical activity does not harm the pelvic floor and does provide numerous health benefits for

  2. Comparing the influence of crestal cortical bone and sinus floor cortical bone in posterior maxilla bi-cortical dental implantation: a three-dimensional finite element analysis.

    Science.gov (United States)

    Yan, Xu; Zhang, Xinwen; Chi, Weichao; Ai, Hongjun; Wu, Lin

    2015-05-01

    This study aimed to compare the influence of alveolar ridge cortical bone and sinus floor cortical bone in sinus areabi-cortical dental implantation by means of 3D finite element analysis. Three-dimensional finite element (FE) models in a posterior maxillary region with sinus membrane and the same height of alveolar ridge of 10 mm were generated according to the anatomical data of the sinus area. They were either with fixed thickness of crestal cortical bone and variable thickness of sinus floor cortical bone or vice versa. Ten models were assumed to be under immediate loading or conventional loading. The standard implant model based on the Nobel Biocare implant system was created via computer-aided design software. All materials were assumed to be isotropic and linearly elastic. An inclined force of 129 N was applied. Von Mises stress mainly concentrated on the surface of crestal cortical bone around the implant neck. For all the models, both the axial and buccolingual resonance frequencies of conventional loading were higher than those of immediate loading; however, the difference is less than 5%. The results showed that bi-cortical implant in sinus area increased the stability of the implant, especially for immediately loading implantation. The thickness of both crestal cortical bone and sinus floor cortical bone influenced implant micromotion and stress distribution; however, crestal cortical bone may be more important than sinus floor cortical bone.

  3. Analysis of historical gross gamma logging data from BX tank farm

    International Nuclear Information System (INIS)

    MYERS, D.A.

    1999-01-01

    Gross gamma ray logs, recorded from January 1975 through mid-year 1994 as part of the Single-Shell Tank Farm Dry Well Surveillance Program, have been reanalyzed for the BX tank farm to locate the presence of mobile radionuclides in the subsurface. This report presents the BX tank farm gross gamma ray data in such a way as to assist others in their study of vadose zone mechanism

  4. Biomimetic matrices for pelvic floor repair

    NARCIS (Netherlands)

    Vashaghian, M.

    2017-01-01

    Pelvic organ prolapsed (POP) is a dysfunctional disease in female pelvic floor that affects a lot of women worldwide, and reduces their quality of life. Currently, trans-vaginal knitted polypropylene meshes are used as secondary treatment, for anatomical correction of the dysfunctional tissues.

  5. Trained, generalized, and collateral behavior changes of preschool children receiving gross-motor skills training.

    OpenAIRE

    Kirby, K C; Holborn, S W

    1986-01-01

    Three preschool children participated in a behavioral training program to improve their gross-motor skills. Ten target behaviors were measured in the training setting to assess direct effects of the program. Generalization probes for two gross-motor behaviors, one fine-motor skill, and two social behaviors were conducted in other settings. Results indicated that the training program improved the gross-motor skills trained and that improvements sometimes generalized to other settings. Contrary...

  6. The floor effect: impoverished spatial memory for elevator buttons.

    Science.gov (United States)

    Vendetti, Michael; Castel, Alan D; Holyoak, Keith J

    2013-05-01

    People typically remember objects to which they have frequently been exposed, suggesting that memory is a by-product of perception. However, prior research has shown that people have exceptionally poor memory for the features of some objects (e.g., coins) to which they have been exposed over the course of many years. Here, we examined how people remember the spatial layout of the buttons on a frequently used elevator panel, to determine whether physical interaction (rather than simple exposure) would ensure the incidental encoding of spatial information. Participants who worked in an eight-story office building displayed very poor recall for the elevator panel but above-chance performance on a recognition test. Performance was related to how often and how recently the person had used the elevator. In contrast to their poor memory for the spatial layout of the elevator buttons, most people readily recalled small distinctive graffiti on the elevator walls. In a more implicit test, the majority were able to locate their office floor and the eighth floor button when asked to point toward these buttons when in the actual elevator, with the button labels covered. However, identification was very poor for other floors (including the first floor), suggesting that even frequent interaction with information does not always lead to accurate spatial memory. These findings have implications for understanding the complex relationships among attention, expertise, and memory.

  7. Introduction to the feature section on functional imaging of the pelvic floor.

    Science.gov (United States)

    Maccioni, Francesca

    2013-10-01

    This is the introduction to the feature section of functional imaging of the pelvic floor, which includes 6 articles, two focused on clinical issues, while four on radiological aspects, mostly on dynamic pelvic floor MRI.

  8. Test plan for K Basin Sludge Canister and Floor Sampling Device

    International Nuclear Information System (INIS)

    Meling, T.A.

    1995-01-01

    This document provides the test plan and procedure forms for conducting the functional and operational acceptance testing of the K Basin Sludge Canister and Floor Sampling Device(s). These samplers samples sludge off the floor of the 100K Basins and out of 100K fuel storage canisters

  9. Pelvic floor exercises during and after pregnancy: a systematic review of their role in preventing pelvic floor dysfunction.

    Science.gov (United States)

    Harvey, Marie-Andrée

    2003-06-01

    To review the literature on the origin, anatomical rationale, techniques, and evidence-based effectiveness of peripartum pelvic floor exercises (PFEs) in the prevention of pelvic floor problems including urinary and anal incontinence, and prolapse. Literature was reviewed for background information. MEDLINE, EMBASE, CINAHL, and proceedings of scientific meetings were searched for evidence-based data. A comprehensive literature search was performed to find all studies that involved the use of antepartum and/or postpartum PFEs. For the MEDLINE (1966 to 2002) and CINAHL (1980 to 2002) searches, the following key words were used: urinary incontinence (prevention and control, rehabilitation, therapy), fecal incontinence, exercise or exercise therapy, Kegel, muscle contraction, muscle tonus, muscle development, pelvic floor, pregnancy, puerperium, puerperal disorders. For the EMBASE (1980 to 2002) search, the following key words were used: micturition disorder (prevention, rehab, disease management, therapy), fecal incontinence, labour complication, pregnancy disorder, puerperal disorder, antepartum care, pregnancy, kinesiotherapy, exercise, pelvic floor, bladder. A manual search was performed of available abstracts presented at the annual scientific meetings of the International Continence Society (1997, 1999 to 2002), American Urogynecologic Association (1997 to 1998, 2000 to 2002), and International Urogynecological Association (1997, 1999 to 2002). Twelve studies evaluating the role of antepartum PFE were found, of which 3 randomized controlled trials (RCTs) comparing PFEs for the prevention of urinary incontinence to controls were included. Twelve studies evaluating postpartum PFEs for prevention of urinary incontinence were reviewed, of which 4 RCTs were included. Five studies evaluating postpartum PFEs for the prevention of anal incontinence were reviewed, of which 4 RCTs were included. Participants in the studies were primiparous women. DATA TABULATION AND

  10. Modeling of the Gross Regional Product on the Basis of Production Functions

    Science.gov (United States)

    Sadovin, Nikolay S.; Kokotkina, Tatiana N.; Barkalova, Tatiana G.; Tsaregorodsev, Evgeny I.

    2016-01-01

    The article is devoted to elaboration and construction of a static model of macroeconomics in which economics is considered as an unstructured holistic unit, the input of which receives the resources, and the output is the result of the functioning of economics in the form of gross domestic product or gross regional product. Resources are…

  11. Assessing the ability of three land ecosystem models to simulate gross carbon uptake of forests from boreal to Mediterranean climate in Europe

    NARCIS (Netherlands)

    Jung, M.; Le Maire, Guerric; Zaehle, S.; Luyssaert, S.; Vetter, M.; Churkina, G.; Ciais, P.; Viovy, N.; Reichstein, M.

    2007-01-01

    Three terrestrial biosphere models (LPJ, Orchidee, Biome-BGC) were evaluated with respect to their ability to simulate large-scale climate related trends in gross primary production (GPP) across European forests. Simulated GPP and leaf area index (LAI) were compared with GPP estimates based on flux

  12. Controls on gross fluxes of nitrous oxide and methane from an active agricultural ecosystem

    Science.gov (United States)

    Yang, W. H.; Silver, W. L.

    2013-12-01

    Agricultural soils can be a significant source of greenhouse gas emissions. Most research on the dynamics of these gases measure net fluxes across the soil-atmosphere interface. This approach limits our ability to determine driving variables because production and consumption processes occur simultaneously, and may be controlled by different factors. We used the trace gas stable isotope pool dilution technique to simultaneously measure field rates of gross production and consumption of N2O and CH4 during the growing season in a corn field located in the Sacramento-San Joaquin Delta, California. We also measured net nitrogen (N) mineralization and nitrification rates, soil temperature, soil moisture, and soil carbon dioxide (CO2) emissions to explore their role as drivers of greenhouse gas fluxes. Across five sampling dates spanning from seeding to senescence, net N2O fluxes ranged from 0 - 4.5 mg N m-2 d-1 and averaged 1.6 × 0.2 mg N m-2 d-1 (n = 112). Gross N2O production ranged from 0.09 - 6.6 mg N m-2 d-1 and gross N2O reduction rates ranged from 0.00 - 0.95 mg N m-2 d-1. The N2O yield averaged 0.68 × 0.02 (n = 40). At peak growth (days after seeding 59 and 94), 89 % of the variability in gross N2O production rates was predicted by the combination of soil moisture, soil temperature, net N mineralization, and CO2 emissions (n = 15, p seeding 11, 24, and 171), gross N2O production was most strongly correlated with soil temperature (R2 = 0.20, n = 24, p = 0.03), and gross N2O reduction rates were best predicted by CO2 emissions (R2 = 0.80, n =24, p production in 36 out of 37 measurements. Gross CH4 production reached as high as 5.4 mg C m-2 d-1 with rates trending higher throughout the growing season. Gross CH4 production rates were marginally significantly higher in rows than in inter-rows (p = 0.10). Gross CH4 oxidation did not differ significantly among sampling dates (Figure 2b), averaging 1.1 × 0.2 mg C m-2 d-1 across all measurements (n = 37). However

  13. Long term performance of a solar floor and hot water heating house; Taiyonetsu yukadanbo kyuto jutaku no choki seino

    Energy Technology Data Exchange (ETDEWEB)

    Udagawa, M [Kogakuin University, Tokyo (Japan)

    1997-11-25

    Outlined herein are measured energy consumption followed for 12 years for a totally electrified solar house with a floor-heating and hot-water heating system. In the solar system, hot water generated by the solar collector is sent, via a surge tank, to a living room, dining room and study to heat their concrete floors, and recycled back to the collector after heating the heat-storage tank for hot water supply. The collector is of plate type, consisting of 6 units, each with a white glass sheet as the heat-collecting membrane for selectively absorbing heat. Its total heat-collecting area is 11.4m{sup 2}. Long-term performance of the solar system installed for floor and hot-water heating in a totally electrified solar house, is analyzed by the measured results collected for 12 years. The house consumes secondary energy of 11.7MWh/year on the average, which is approximately 20% lower that that required for a house of the equivalent size. The solar system has been operated smoothly, to supply 46 and 35% of the required heat for hot-water and floor heating. It is however estimated that annual heat loss reaches 34% in the hot-water heating system, including that in the electric hot-water generator, and prevention of heat loss is one of the major themes for the future system designs. 4 refs., 5 figs.

  14. Quality of life in women with pelvic floor dysfunction

    OpenAIRE

    Mladenović-Segedi Ljiljana; Parezanović-Ilić Katarina; Ćurčić Aleksandar; Višnjevac Nemanja

    2011-01-01

    Background/Aim. Pelvic floor dysfunction is a frequent problem affecting more than 50% of women in peri- and postmenopause. Considering that ageing and menopause befall in the significant factors causing this issue, as well as the expected longevity of women in the world and in our country, pelvic floor dysfunction prevelence is foreseen to be even higher. The aim of the study was to evaluate impact of the symptoms of pelvic dysfunction on quality of life and examine body image satisfac...

  15. Data Reconciliation and Gross Error Detection for Troubleshooting of Ammonia Reactor

    Directory of Open Access Journals (Sweden)

    Adhi Tri Partono

    2018-01-01

    Full Text Available Data reconciliation (DR and gross error detection are two common tools used in industry to provide accurate and reliable data, which is useful to analyse plant performance and basis for troubleshooting. DR techniques improve the accuracy of measurements by using redundancies in material and energy balances. This provides reliable information that could help decision making regarding plant operation, which potentially leads to financial benefit. This paper presents the utilization of plant data to perform troubleshooting of ammonia reactor, in particular the profile of catalyst activity. Bad plant data are collected and then analysed using DR to produces reconciled data, which could be used to detect and identify the gross error measurements. The input data for DR and gross error detection were gathered from Aspen HYSYS V8.8 simulations by modelling the single-bed ammonia reactor. The result presents that bad plant data could define actual system condition such as gross error measurements in normal condition or catalyst activity problem. Both conditions are modelled by DR to indicate actual system condition using statistical analysis and to perform troubleshooting. Appropriate troubleshooting could save time and provide financial benefits by avoiding wrong accusation of system problem, specifically in ammonia reactor evaluated in this paper.

  16. Factors Associated with Enhanced Gross Motor Progress in Children with Cerebral Palsy: A Register-Based Study.

    Science.gov (United States)

    Størvold, Gunfrid V; Jahnsen, Reidun B; Evensen, Kari Anne I; Romild, Ulla K; Bratberg, Grete H

    2018-05-01

    To examine associations between interventions and child characteristics; and enhanced gross motor progress in children with cerebral palsy (CP). Prospective cohort study based on 2048 assessments of 442 children (256 boys, 186 girls) aged 2-12 years registered in the Cerebral Palsy Follow-up Program and the Cerebral Palsy Register of Norway. Gross motor progress estimates were based on repeated measures of reference percentiles for the Gross Motor Function Measure (GMFM-66) in a linear mixed model. Mean follow-up time: 2.9 years. Intensive training was the only intervention factor associated with enhanced gross motor progress (mean 3.3 percentiles, 95% CI: 1.0, 5.5 per period of ≥3 sessions per week and/or participation in an intensive program). Gross motor function was on average 24.2 percentiles (95% CI: 15.2, 33.2) lower in children with intellectual disability compared with others. Except for eating problems (-10.5 percentiles 95% CI: -18.5, -2.4) and ankle contractures by age (-1.9 percentiles 95% CI: -3.6, -0.2) no other factors examined were associated with long-term gross motor progress. Intensive training was associated with enhanced gross motor progress over an average of 2.9 years in children with CP. Intellectual disability was a strong negative prognostic factor. Preventing ankle contractures appears important for gross motor progress.

  17. Divergence of fine and gross motor skills in prelingually deaf children: implications for cochlear implantation.

    Science.gov (United States)

    Horn, David L; Pisoni, David B; Miyamoto, Richard T

    2006-08-01

    The objective of this study was to assess relations between fine and gross motor development and spoken language processing skills in pediatric cochlear implant users. The authors conducted a retrospective analysis of longitudinal data. Prelingually deaf children who received a cochlear implant before age 5 and had no known developmental delay or cognitive impairment were included in the study. Fine and gross motor development were assessed before implantation using the Vineland Adaptive Behavioral Scales, a standardized parental report of adaptive behavior. Fine and gross motor scores reflected a given child's motor functioning with respect to a normative sample of typically developing, normal-hearing children. Relations between these preimplant scores and postimplant spoken language outcomes were assessed. In general, gross motor scores were found to be positively related to chronologic age, whereas the opposite trend was observed for fine motor scores. Fine motor scores were more strongly correlated with postimplant expressive and receptive language scores than gross motor scores. Our findings suggest a disassociation between fine and gross motor development in prelingually deaf children: fine motor skills, in contrast to gross motor skills, tend to be delayed as the prelingually deaf children get older. These findings provide new knowledge about the links between motor and spoken language development and suggest that auditory deprivation may lead to atypical development of certain motor and language skills that share common cortical processing resources.

  18. PELVIC FLOOR MUSCLE TRAINING IN THE TREATMENT OF URINARY INCONTINENCE AFTER RADICAL PROSTATECTOMY

    Directory of Open Access Journals (Sweden)

    Yu. L. Demidko

    2014-07-01

    Full Text Available The incidence of urinary incontinence after radical prostatectomy is 0.8 to 87%. This category of patients has pelvic floor muscle weakness and reduced perineal reflex. The treatment of these patients uses a pelvic floor exercise system that is to enhance muscle tone and to develop strong reflex contraction in response to a sudden rise in intraabdominal pressure. Pelvic floor muscle training belongs to first-line therapy for urinary incontinence occurring within 6 to 12 months after prostatectomy. The ability to control pelvic floor muscle knowingly and to train them allows one not only to increase the closing capability of sphincter mechanisms, but also to suppress involuntary detrusor contractions. We used this method in 9 patients who had undergone radical prostatectomy. The duration of pelvic floor muscle training under control was up to 25 weeks. During this period, the symptoms of incontinence were relieved. No contraindications or adverse reactions have put this method in first-line therapy for post-prostatectomy urinary incontinence.

  19. PELVIC FLOOR MUSCLE TRAINING IN THE TREATMENT OF URINARY INCONTINENCE AFTER RADICAL PROSTATECTOMY

    Directory of Open Access Journals (Sweden)

    Yu. L. Demidko

    2010-01-01

    Full Text Available The incidence of urinary incontinence after radical prostatectomy is 0.8 to 87%. This category of patients has pelvic floor muscle weakness and reduced perineal reflex. The treatment of these patients uses a pelvic floor exercise system that is to enhance muscle tone and to develop strong reflex contraction in response to a sudden rise in intraabdominal pressure. Pelvic floor muscle training belongs to first-line therapy for urinary incontinence occurring within 6 to 12 months after prostatectomy. The ability to control pelvic floor muscle knowingly and to train them allows one not only to increase the closing capability of sphincter mechanisms, but also to suppress involuntary detrusor contractions. We used this method in 9 patients who had undergone radical prostatectomy. The duration of pelvic floor muscle training under control was up to 25 weeks. During this period, the symptoms of incontinence were relieved. No contraindications or adverse reactions have put this method in first-line therapy for post-prostatectomy urinary incontinence.

  20. The Schroedinger functional for Gross-Neveu models

    International Nuclear Information System (INIS)

    Leder, B.

    2007-01-01

    Gross-Neveu type models with a finite number of fermion flavours are studied on a two-dimensional Euclidean space-time lattice. The models are asymptotically free and are invariant under a chiral symmetry. These similarities to QCD make them perfect benchmark systems for fermion actions used in large scale lattice QCD computations. The Schroedinger functional for the Gross-Neveu models is defined for both, Wilson and Ginsparg-Wilson fermions, and shown to be renormalisable in 1-loop lattice perturbation theory. In two dimensions four fermion interactions of the Gross-Neveu models have dimensionless coupling constants. The symmetry properties of the four fermion interaction terms and the relations among them are discussed. For Wilson fermions chiral symmetry is explicitly broken and additional terms must be included in the action. Chiral symmetry is restored up to cut-off effects by tuning the bare mass and one of the couplings. The critical mass and the symmetry restoring coupling are computed to second order in lattice perturbation theory. This result is used in the 1-loop computation of the renormalised couplings and the associated beta-functions. The renormalised couplings are defined in terms of suitable boundary-to-boundary correlation functions. In the computation the known first order coefficients of the beta-functions are reproduced. One of the couplings is found to have a vanishing betafunction. The calculation is repeated for the recently proposed Schroedinger functional with exact chiral symmetry, i.e. Ginsparg-Wilson fermions. The renormalisation pattern is found to be the same as in the Wilson case. Using the regularisation dependent finite part of the renormalised couplings, the ratio of the Lambda-parameters is computed. (orig.)

  1. Carbon and nitrogen in forest floor and mineral soil under six common European tree species

    DEFF Research Database (Denmark)

    Vesterdal, Lars; Schmidt, Inger K.; Callesen, Ingeborg

    2007-01-01

    The knowledge of tree species effects on soil C and N pools is scarce, particularly for European deciduous tree species. We studied forest floor and mineral soil carbon and nitrogen under six common European tree species in a common garden design replicated at six sites in Denmark. Three decades...... on forest floor C and N content was primarily attributed to large differences in turnover rates as indicated by fractional annual loss of forest floor C and N. The C/N ratio of foliar litterfall was a good indicator of forest floor C and N contents, fractional annual loss of forest floor C and N...

  2. 77 FR 5429 - Proposed Modification of the Atlanta Class B Airspace Area; GA

    Science.gov (United States)

    2012-02-03

    ... consisted of lower Class B floors within a reduced radius of 30 NM from the ATL VORTAC as opposed to the... concerns related to the proposed lower Class B airspace floors, particularly in the airspace directly... congestion at lower altitudes due to VFR traffic trying to avoid flying in the Class B airspace area and...

  3. 76 FR 92 - Multilayered Wood Flooring From the People's Republic of China: Postponement of Preliminary...

    Science.gov (United States)

    2011-01-03

    ... DEPARTMENT OF COMMERCE International Trade Administration [C-570-971] Multilayered Wood Flooring... Department'') initiated an investigation of multilayered wood flooring from the People's Republic of China (``PRC''). See Multilayered Wood Flooring From the People's Republic of China: Initiation of...

  4. State-of-the-art of development of floor spectra

    International Nuclear Information System (INIS)

    Singh, M.P.

    1984-01-01

    Floor spectra are used as seismic inputs for the design and qualification of subsystems and equipment. Until very recently, the time history analyses with single acceleration time history as input were very commonly used. However, this approach has been observed to give nonunique floor spectrum curves. Thus, as alternatives several direct approaches have been developed. The approaches which are based on the random vibration principles but employ response spectra directly have more rational appeal. Several such approaches are available. Four different approaches, employing the mode displacement and mode acceleration formulations, covering the proportionally as well as nonproportionally damped structures, are presented. The mode displacement formulations are most commonly used, although the mode acceleration formulations seem to be the better alternatives, both for the proportionally and nonproportionally damped structures. The need for the development of other forms of floor response spectra such as the relative velocity and relative acceleration spectra is also identified

  5. Pelvic floor disorders in gynecological malignancies. An overlooked problem?

    Directory of Open Access Journals (Sweden)

    Oana M. Bodean

    2018-04-01

    Full Text Available Cervical, endometrial, ovarian, vulvar, and vaginal cancers affect women of a broad age spectrum. Many of these women are still sexually active when their cancer is diagnosed. Treatment options for gynecological malignancies, such as gynecological surgery, radiation, and chemotherapy, are proven risk factors for pelvic floor dysfunction. The prevalence of urinary incontinence, fecal incontinence, and sexual dysfunction before cancer treatment is still unclear. Hypotheses have been raised in the literature that these manifestations could represent early symptoms of pelvic cancers, but most remain overlooked even in cancer surviving patients. The primary focus of therapy is always cancer eradication, but as oncological and surgical treatment options become more successful, the number of cancer survivors increases. The quality of life of patients with gynecological cancers often remains an underrated subject. Pelvic floor disorders are not consistently reported by patients and are frequently overlooked by many clinicians. In this brief review we discuss the importance of pelvic floor dysfunction in patients with gynecological malignant tumors.

  6. Relationship between female pelvic floor dysfunction and sexual dysfunction: an observational study.

    Science.gov (United States)

    Bortolami, Arianna; Vanti, Carla; Banchelli, Federico; Guccione, Andrew A; Pillastrini, Paolo

    2015-05-01

    The ability to express one's sexuality and engage in sexual activity requires multisystemic coordination involving many psychological functions as well as the integrity of the nervous, hormonal, vascular, immune, and neuromuscular body structures and functions. The purpose of this study was to investigate the associations among pelvic floor function, sexual function, and demographic and clinical characteristics in a population of women initiating physical therapy evaluation and treatment for pelvic floor-related dysfunctions (urinary incontinence, pelvic organ prolapse, vulvodynia, vaginismus, and constipation). We consented and collected completed demographic data and data related to symptoms and clinical condition on 85 consecutive patients in an outpatient physical therapy clinic. Clinical and anthropometric characteristics were analyzed descriptively. Analysis of variance and linear regression analyses were used to analyze Female Sexual Function Index (FSFI) scale ratings, whereas zero-inflated beta-binomial regression was applied to the pain subscale. Main outcome measure was FSFI score, whereas the secondary outcome measure was the FSFI subscale score related to pain. Women in our sample were 38 years old on average, 33% of whom had given birth and 82% of whom had high tone pelvic floor. Being in the middle-tercile age group and exhibiting low pelvic floor tone (Beta = 6.8; 95% confidence interval [CI] = [1.4; 12.0]) were significantly associated with lower levels of sexual dysfunction. Women with low tone pelvic floor also reported lower pain (odds ratio = 4.0; 95% CI = [1.6; 9.6]), whereas younger aged and physically unsatisfied subjects were more likely not to have sexual activity in the month prior to scale measurement. In female patients with pelvic floor muscle dysfunction undergoing physical therapy and rehabilitation, sexual dysfunction appears to be significantly correlated with age and high pelvic floor muscle tone. © 2015

  7. Comparison of a gross anatomy laboratory to online anatomy software for teaching anatomy.

    Science.gov (United States)

    Mathiowetz, Virgil; Yu, Chih-Huang; Quake-Rapp, Cindee

    2016-01-01

    This study was designed to assess the grades, self-perceived learning, and satisfaction between occupational therapy students who used a gross anatomy laboratory versus online anatomy software (AnatomyTV) as tools to learn anatomy at a large public university and a satellite campus in the mid-western United States. The goal was to determine if equivalent learning outcomes could be achieved regardless of learning tool used. In addition, it was important to determine why students chose the gross anatomy laboratory over online AnatomyTV. A two group, post-test only design was used with data gathered at the end of the course. Primary outcomes were students' grades, self-perceived learning, and satisfaction. In addition, a survey was used to collect descriptive data. One cadaver prosection was available for every four students in the gross anatomy laboratory. AnatomyTV was available online through the university library. At the conclusion of the course, the gross anatomy laboratory group had significantly higher grade percentage, self-perceived learning, and satisfaction than the AnatomyTV group. However, the practical significance of the difference is debatable. The significantly greater time spent in gross anatomy laboratory during the laboratory portion of the course may have affected the study outcomes. In addition, some students may find the difference in (B+) versus (A-) grade as not practically significant. Further research needs to be conducted to identify what specific anatomy teaching resources are most effective beyond prosection for students without access to a gross anatomy laboratory. © 2015 American Association of Anatomists.

  8. Acute radiotherapy toxicity in 57 dogs with gross and microscopic mast cell tumours.

    Science.gov (United States)

    Blackwood, L; Tanis, J B; Harper, A; Amores-Fuster, I; Killick, D R; Finotello, R

    2018-05-15

    Mast cell tumours (MCTs) are commonly treated with radiation therapy, most often in a microscopic disease setting. Poorer outcomes are expected in patients with gross disease, and irradiation of gross disease may be associated with greater toxicity. The aim of this study was to compare acute radiation adverse events (AE) in dogs with gross and microscopic MCTs receiving radiotherapy. Fifty-seven dogs were included, 28 with gross disease and 29 with microscopic. In order to assess mucosal and skin toxicity, patients were assigned to 2 groups: head (29 patients, 14 patients with gross and 15 microscopic) and other sites (28 patients, 14 each). All were treated with external beam radiotherapy, and toxicity assessed at the end of treatment and 10 to 14 days later (first recheck). All patients developed some acute radiation toxicity by the end of the course. However, there was no difference in the severity of toxicity between gross and microscopic disease in either site group at either time point. The only variable associated with an increased frequency of grade 2 or 3 toxicity at the first recheck was the use of prednisolone prior to radiotherapy (P = .05). No other factors were identified which were associated with increased toxicity. For the head group, the site of highest grade toxicity was mucosa or, if included in the field, nasal planum, which was often more severely affected than the mucosa. No significant late toxicity was identified. Two dogs developed acute haematemesis during the radiotherapy course, but both completed the course without further events. © 2018 John Wiley & Sons Ltd.

  9. Seismic proving test of process computer systems with a seismic floor isolation system

    International Nuclear Information System (INIS)

    Fujimoto, S.; Niwa, H.; Kondo, H.

    1995-01-01

    The authors have carried out seismic proving tests for process computer systems as a Nuclear Power Engineering Corporation (NUPEC) project sponsored by the Ministry of International Trade and Industry (MITI). This paper presents the seismic test results for evaluating functional capabilities of process computer systems with a seismic floor isolation system. The seismic floor isolation system to isolate the horizontal motion was composed of a floor frame (13 m x 13 m), ball bearing units, and spring-damper units. A series of seismic excitation tests was carried out using a large-scale shaking table of NUPEC. From the test results, the functional capabilities during large earthquakes of computer systems with a seismic floor isolation system were verified

  10. Effect of space allowance and flooring on the behavior of pregnant ewes.

    Science.gov (United States)

    Vik, S G; Øyrehagen, O; Bøe, K E

    2017-05-01

    Space allowance recommendations for pregnant ewes vary considerably. The aim of this experiment was to investigate the effect of space allowance and floor type on activity, lying position, displacements, and aggressive interactions in pregnant ewes. A 3 × 2 factorial experiment was conducted with space allowance (0.75, 1.50, and 2.25 m/ewe) and type of flooring (straw bedding and expanded metal flooring) as the main factors. A total of 48 pregnant ewes were randomly assigned to 6 groups with 8 ewes in each group. All groups were exposed to each treatment for 7 d. The ewes were video recorded for 24 h at the end of each treatment period and general activity, lying position in the pen, and social lying position were scored every 15 min. Displacements and aggressive interactions were scored continuously from 1030 to 1430 h. Mean lying time ( flooring had no significant effect on general activity. Ewes in the straw bedding treatment spent more time lying in the middle of the pen than ewes on expanded metal ( flooring. Hence, recommended space allowance for pregnant ewes should not be lower than 1.50 m/ewe.

  11. Floor surface decontaminating device for use in nuclear power plants

    International Nuclear Information System (INIS)

    Yoshida, Tomiji; Ue, Tatsuyuki; Omori, Nobuya; Okuzawa, Tsutomu.

    1987-01-01

    Purpose: To obtain a device for decontaminating the floor surfaces contaminated with radioactive materials in nuclear power plants or the likes, mechanically, automatically and effectively. Constitution: During running of the device by means of running wheels and castors, a decontaminating head is always applied with vibrations by a vibrator. In this state, wiping members are sent from a delivery roll, applied with vibrations at the decontaminating head. The members wipe off contamination products while in frictional contact with the floor surface and are then taken up to a winding roll with the contamination products deposited thereto. In this case, since the vibrations from the decontaminating head are transmitted by way of a resilient portion thereof to the wiping members, the vibrations transmitted from the wiping members to the floor surface are somewhat buffered. (Kawakami, Y.)

  12. Fine and gross motor skills: The effects on skill-focused dual-tasks.

    Science.gov (United States)

    Raisbeck, Louisa D; Diekfuss, Jed A

    2015-10-01

    Dual-task methodology often directs participants' attention towards a gross motor skill involved in the execution of a skill, but researchers have not investigated the comparative effects of attention on fine motor skill tasks. Furthermore, there is limited information about participants' subjective perception of workload with respect to task performance. To examine this, the current study administered the NASA-Task Load Index following a simulated shooting dual-task. The task required participants to stand 15 feet from a projector screen which depicted virtual targets and fire a modified Glock 17 handgun equipped with an infrared laser. Participants performed the primary shooting task alone (control), or were also instructed to focus their attention on a gross motor skill relevant to task execution (gross skill-focused) and a fine motor skill relevant to task execution (fine skill-focused). Results revealed that workload was significantly greater during the fine skill-focused task for both skill levels, but performance was only affected for the lesser-skilled participants. Shooting performance for the lesser-skilled participants was greater during the gross skill-focused condition compared to the fine skill-focused condition. Correlational analyses also demonstrated a significant negative relationship between shooting performance and workload during the gross skill-focused task for the higher-skilled participants. A discussion of the relationship between skill type, workload, skill level, and performance in dual-task paradigms is presented. Copyright © 2015 Elsevier B.V. All rights reserved.

  13. The Association between Residence Floor Level and Cardiovascular Disease: The Health and Environment in Oslo Study.

    Science.gov (United States)

    Rohde, Mads K; Aamodt, Geir

    2016-01-01

    Background. Increasingly more people live in tall buildings and on higher floor levels. Factors relating to floor level may protect against or cause cardiovascular disease (CVD). Only one previous study has investigated the association between floor level and CVD. Methods. We studied associations between floor of bedroom and self-reported history of stroke, venous thromboembolism (VTE), and intermittent claudication (IC) among 12.525 inhabitants in Oslo, Norway. We fitted multivariate logistic regression models and adjusted for sociodemographic variables, socioeconomic status (SES), and health behaviors. Additionally, we investigated block apartment residents ( N = 5.374) separately. Results. Trend analyses showed that disease prevalence increased by floor level, for all three outcomes. When we investigated block apartment residents alone, the trends disappeared, but one association remained: higher odds of VTE history on 6th floor or higher, compared to basement and 1st floor (OR: 1.504; 95% CI: 1.007-2.247). Conclusion. Floor level is positively associated with CVD, in Oslo. The best-supported explanation may be residual confounding by building height and SES. Another explanation, about the impact of atmospheric electricity, is also presented. The results underline a need to better understand the associations between residence floor level and CVD and multistory housing and CVD.

  14. Are gross motor skills and sports participation related in children with intellectual disabilities?

    NARCIS (Netherlands)

    Westendorp, Marieke; Houwen, Suzanne; Hartman, Esther; Visscher, Chris

    2011-01-01

    This study compared the specific gross motor skills of 156 children with intellectual disabilities (ID) (50 79) with that of 255 typically developing children, aged 7-12 years. Additionally, the relationship between the specific gross motor skills and organized sports participation was examined

  15. Solitons in Gross-Pitaevskii equation

    International Nuclear Information System (INIS)

    Lopes, E.

    1985-01-01

    It is observed that, when the potential is integrable and repulsive, the Gross-Pitaevskii Equation, with non-vanishing boundary conditions, describes a family of planar solitons. A method is presented which provides an exact soliton field to the Dirac Delta potential and an approximation solution to any other kind of potential. As an example the method is then applied to the case of a repulsive Yukawa potential. A brief discuss the relation between these solitons and Anderson's superfluidity mechanism, is also presented. (author) [pt

  16. MODELING AND IMPLEMENTATION OF A DISTRIBUTED SHOP FLOOR MANAGEMENT AND CONTROL SYSTEM

    Institute of Scientific and Technical Information of China (English)

    2002-01-01

    Adopting distributed control architecture is the important development direction for shop floor management and control system,is also the requirement of making it agile,intelligent and concurrent. Some key problems in achieving distributed control architecture are researched. An activity model of shop floor is presented as the requirement definition of the prototype system. The multi-agent based software architecture is constructed. How the core part in shop floor management and control system,production plan and scheduling is achieved. The cooperation of different agents is illustrated. Finally,the implementation of the prototype system is narrated.

  17. The new energy management policy: Indonesian PSC-gross-split applied on steam flooding project

    Science.gov (United States)

    Irham, S.; Julyus, P.

    2018-01-01

    “SIPY” oil field has been producing oil using steam flooding technology since 1992 under the PSC-Cost-Recovery policy. In 2021, the contract will be finished, and a new agreement must be submitted to the Indonesian government. There are two applied fiscal policies on oil and gas management: PSC-Cost-Recovery and PSC-Gross-Split (introduced in 2017 as the new energy management plan). The contractor must choose between PSC-Cost-Recovery and PSC-Gross-split which makes more profit. The aim of this research is to determine the best oil and gas contract policy for the contractor. The methods are calculating contractor cash flow and comparing the Profitability Indexes. The results of this study are (1) Net Present Values for the PSC-Cost-Recovery and the PSC-Gross-Split are 15 MMUS and 61 MMUS, respectively; and (2) Internal Rate of Return values for the PSC-Cost-Recovery and PSC-Gross-Split are 10% and 11%, respectively. The conclusion is that the Net Present Value and Internal Rate of Return of PSC-Gross-Split are greater than those of PSC-Cost-Recovery, but in Pay Out Time of PSC-Gross-split is longer than Pay Out Time in PSC-Cost-Recovery. Thus, the new energy management policy will be more attractive than PSC-Cost-Recovery.

  18. The new management policy: Indonesian PSC-Gross split applied on CO2 flooding project

    Science.gov (United States)

    Irham, S.; Sibuea, S. N.; Danu, A.

    2018-01-01

    “SIAD” oil field will be developed by CO2 flooding. CO2, a famous pollutant gas, is injected into the oil reservoir to optimize the oil recovery. This technique should be conducted economically according to the energy management policy in Indonesia. In general, Indonesia has two policy contracts on oil and gas: the old one is PSC-Cost-Recovery, and the new one is PSC-Gross-Split (introduced in 2017 as the new energy management plan). The contractor must choose between PSC-Cost-Recovery and PSC-Gross-Split which makes more profit. The aim of this paper is to show the best oil and gas contract policy for the contractor. The methods are calculating and comparing the economic indicators. The result of this study are (1) NPV for the PSC-Cost-Recovery is -46 MUS, while for the PSC-Gross-Split is 73 MUS, and (2) IRR for the PSC-Cost-Recovery is 9%, whereas for the PSC-Gross-Split is 11%. The conclusion is that the NPV and IRR for PSC-Gross-Split are greater than the NPV and IRR of PSC-Cost-Recovery, but POT in PSC-Gross-split is longer than POT in PSC-Cost-Recovery. Thus, in this case, the new energy policy contract can be applied for CO2 flooding technology since it yields higher economic indicators than its antecendent.

  19. Mechanical decontamination techniques for floor drain systems

    International Nuclear Information System (INIS)

    Palau, G.L.

    1987-01-01

    The unprecedented nature of cleanup activities at Three Mile Island Unit 2 (TMI-2) following the 1979 accident has necessitated the development of new techniques to deal with radiation and contamination in the plant. One of these problems was decontamination of floor drain systems, which had become highly contaminated with various forms of dirt and sludge containing high levels of fission products and fuel from the damaged reactor core. The bulk of this contamination is loosely adherent to the drain pipe walls; however, significant amounts of contamination have become incorporated into pipe wall oxide and corrosion layers and embedded in microscopic pits and fissures in the pipe wall material. The need to remove this contamination was recognized early in the TMI-2 cleanup effort. A program consisting of development and laboratory testing of floor drain decontamination techniques was undertaken early in the cleanup with support from the Electric Power Research Institute (EPRI). Based on this initial research, two techniques were judged to show promise for use at TMI-2: a rotating brush hone system and a high-pressure water mole nozzle system. Actual use of these devices to clean floor drains at TMI-2 has yielded mixed decontamination results. The decontamination effectiveness that has been obtained is highly dependent on the nature of the contamination in the drain pipe and the combination of decontamination techniques used

  20. Gross efficiency and energy expenditure in kayak ergometer exercise.

    Science.gov (United States)

    Gomes, B B; Mourão, L; Massart, A; Figueiredo, P; Vilas-Boas, J P; Santos, A M C; Fernandes, R J

    2012-08-01

    We purposed to study energy expenditure, power output and gross efficiency during kayak ergometer exercise in 12 elite sprint kayakers. 6 males (age 24.2±4.8 years, height 180.4±4.8 cm, body mass 79.7±8.5 kg) and 6 females (age 24.3±4.5 years, height 164.5±3.9 cm, body mass 65.4±3.5 kg), performed an incremental intermittent protocol on kayak ergometer with VO2 and blood lactate concentration assessment, a non-linear increase between power output and energy expenditure being observed. Paddling power output, energy expenditure and gross efficiency corresponding to VO2max averaged 199.92±50.41 W, 75.27±6.30 ml.kg - 1.min - 1, and 10.10±1.08%. Male kayakers presented higher VO2max, power output and gross efficiency at the VO2max, and lower heart rate and maximal lactate concentration than females, but no differences were found between genders regarding energy expenditure at VO2max. Aerobic and anaerobic components of energy expenditure evidenced a significant contribution of anaerobic energy sources in sprint kayak performance. Results also suggested the dependence of the gross efficiency on the changes in the amount of the aerobic and anaerobic contributions, at heavy and severe intensities. The inter-individual variance of the relationship between energy expenditure and the corresponding paddling power output revealed a relevant tracking for females (FDγ=0.73±0.06), conversely to the male group (FDγ=0.27±0.08), supporting that some male kayakers are more skilled in some paddling intensities than others. © Georg Thieme Verlag KG Stuttgart · New York.