WorldWideScience

Sample records for gross combined heat

  1. 77 FR 51706 - Gross Combination Weight Rating (GCWR); Definition

    Science.gov (United States)

    2012-08-27

    ... [Docket No. FMCSA-2012-0156] RIN 2126-AB53 Gross Combination Weight Rating (GCWR); Definition AGENCY... combination weight rating'' (GCWR) in our regulations. The definition currently prescribes how the GCWR is... online docket via http://www.regulations.gov on or before September 26, 2012 or reaches the Docket...

  2. 77 FR 65497 - Gross Combination Weight Rating (GCWR); Definition

    Science.gov (United States)

    2012-10-29

    ... [Docket No. FMCSA-2012-0156] RIN 2126-AB53 Gross Combination Weight Rating (GCWR); Definition AGENCY... combination weight rating'' (GCWR) in 49 CFR parts 383 and 390. The DFR would have taken effect on October 26... you do not have access to the internet, you may also view the docket online by visiting the Docket...

  3. Combined Heat and Power

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2008-07-01

    At their 2007 Summit in Heiligendamm, G8 leaders called on countries to 'adopt instruments and measures to significantly increase the share of combined heat and power (CHP) in the generation of electricity.' As a result, energy, economic, environmental and utility regulators are looking for tools and information to understand the potential of CHP and to identify appropriate policies for their national circumstances. This report forms the first part of the response. It includes answers to policy makers' questions about the potential economic, energy and environmental benefits of an increased policy commitment to CHP. It also includes for the first time integrated IEA data on global CHP installations, and analyses the benefits of increased CHP investment in the G8+5 countries. A companion report will be produced later in 2008 to document best practice policy approaches that have been used to expand the use of CHP in a variety of countries.

  4. Combined Heat and Power

    Science.gov (United States)

    CHP is on-site electricity generation that captures the heat that would otherwise be wasted to provide useful thermal energy such as steam or hot water than can be used for space heating, cooling, domestic hot water and industrial processes.

  5. The EIR-programmes for computing the gross heat output of solar collectors (MURD and ETA)

    International Nuclear Information System (INIS)

    Widder, F.

    1980-11-01

    For the computation of the gross heat output of solar collectors by means of meteo data and characteristic collector parameters two programs were developed: MURD for the determination of the ''mean usable radiation density'' and ETA for the calculation of the collector efficiency i.e. relative values of gross heat output. The main features of these programs are described and detailed instructions for the use of them are given. Results of some cases for the meteo-situation of Zurich airport are given. (Auth.)

  6. Combined climate factors alleviate changes in gross soil nitrogen dynamics in heathlands

    DEFF Research Database (Denmark)

    Bjorsne, Anna-Karin; Rutting, Tobias; Ambus, Per

    2014-01-01

    nitrification was decreased by eCO(2), an effect that was more pronounced when eCO(2) was combined with warming and drought. Moreover, there was an interactive effect between the warming and CO2 treatment, especially for N mineralization: rates increased at warming alone but decreased at warming combined with e......CO(2). In the full treatment combination, simulating the predicted climate for the year 2075, gross N transformations were only moderately affected compared to control, suggesting a minor alteration of the N cycle due to climate change. Overall, our study confirms the importance of multifactorial field...

  7. Combination solar photovoltaic heat engine energy converter

    Science.gov (United States)

    Chubb, Donald L.

    1987-01-01

    A combination solar photovoltaic heat engine converter is proposed. Such a system is suitable for either terrestrial or space power applications. The combination system has a higher efficiency than either the photovoltaic array or the heat engine alone can attain. Advantages in concentrator and radiator area and receiver mass of the photovoltaic heat engine system over a heat-engine-only system are estimated. A mass and area comparison between the proposed space station organic Rankine power system and a combination PV-heat engine system is made. The critical problem for the proposed converter is the necessity for high temperature photovoltaic array operation. Estimates of the required photovoltaic temperature are presented.

  8. Heat pumps in combined heat and power systems

    DEFF Research Database (Denmark)

    Ommen, Torben Schmidt; Markussen, Wiebke Brix; Elmegaard, Brian

    2014-01-01

    Heat pumps have previously been proposed as a way to integrate higher amounts of renewable energy in DH (district heating) networks by integrating, e.g., wind power. The paper identifies and compares five generic configurations of heat pumps in DH systems. The operational performance...... of the considered cases. When considering a case where the heat pump is located at a CHP (combined heat and power) plant, a configuration that increases the DH return temperature proposes the lowest operation cost, as low as 12 EUR MWh-1 for a 90 °C e 40 °C DH network. Considering the volumetric heating capacity......, a third configuration is superior in all cases. Finally, the three most promising heat pump configurations are integrated in a modified PQ-diagram of the CHP plant. Each show individual advantages, and for two, also disadvantages in order to achieve flexible operation....

  9. New waste heat district heating system with combined heat and power based on absorption heat exchange cycle in China

    International Nuclear Information System (INIS)

    Sun Fangtian; Fu Lin; Zhang Shigang; Sun Jian

    2012-01-01

    A new waste heat district heating system with combined heat and power based on absorption heat exchange cycle (DHAC) was developed to increase the heating capacity of combined heat and power (CHP) through waste heat recovery, and enhance heat transmission capacity of the existing primary side district heating network through decreasing return water temperature by new type absorption heat exchanger (AHE). The DHAC system and a conventional district heating system based on CHP (CDH) were analyzed in terms of both thermodynamics and economics. Compared to CDH, the DHAC increased heating capacity by 31% and increased heat transmission capacity of the existing primary side district heating network by 75%. The results showed that the exergetic efficiency of DHAC was 10.41% higher and the product exergy monetary cost was 36.6¥/GJ less than a CHD. DHAC is an effective way to increase thermal utilization factor of CHP, and to reduce district heating cost. - Highlights: ► Absorption heat pumps are used to recover waste heat in CHP. ► Absorption heat exchanger can reduce exergy loss in the heat transfer process. ► New waste heat heating system (DHAC) can increase heating capacity of CHP by 31%. ► DHAC can enhance heat transmission capacity of the primary pipe network by 75%. ► DHAC system has the higher exergetic efficiency and the better economic benefit.

  10. Combined Heat and Power and Emissions Trading

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2008-07-01

    The aim of this IEA Information Paper is to help policy makers and other stakeholders understand the challenges facing the incorporation of high efficiency combined heat and power (CHP) into greenhouse gas (GHG) Emissions Trading Schemes (ETSs) -- and to propose options for overcoming them.

  11. Combined heat and power in the City

    Energy Technology Data Exchange (ETDEWEB)

    Crafter, A. [Corporation of London (United Kingdom). Dept. of Technical Services

    2002-03-01

    This article reports on the development of a large-scale combined heat and power community energy scheme within the City of London. Supported by the Corporation of London and using its own buildings to provide the heating and cooling loads, the scheme has established a power plant close to Smithfield Meat Market and supplies district heating and chilled water for air conditioning to its own properties and some private customers in the nearby districts. Details are given of the power plant which is sited in a conservation area with limited access, the use of absorption chillers to produce the chilled water, the estimated amount of carbon dioxide emissions saved, and the financial benefits of the scheme.

  12. Cost allocation. Combined heat and power production

    International Nuclear Information System (INIS)

    Sidzikauskas, V.

    2002-01-01

    The benefits of Combined Heat and Power (CHP) generation are discussed. The include improvement in energy intensity of 1% by 2010, 85-90% efficiency versus 40-50% of condensation power and others. Share of CHP electricity production in ERRA countries is presented.Solutions for a development CHP cost allocation are considered. Conclusion are presented for CHP production cost allocation. (R.P.)

  13. Chapter 23: Combined Heat and Power

    Energy Technology Data Exchange (ETDEWEB)

    Simons, George [Itron, Davis, CA (United States); Barsun, Stephan [Itron, Davis, CA (United States)

    2016-11-01

    This protocol defines a combined heat and power (CHP) measure as a system that sequentially generates both electrical energy and useful thermal energy from one fuel source at a host customer's facility or residence. This protocol is aimed primarily at regulators and administrators of ratepayer-funded CHP programs; however, project developers may find the protocol useful to understand how CHP projects are evaluated.

  14. Residential CO{sub 2} heat pump system for combined space heating and hot water heating

    Energy Technology Data Exchange (ETDEWEB)

    Stene, Joern

    2004-02-01

    Carbon dioxide (CO{sub 2}, R-744) has been identified as a promising alternative to conventional working fluids in a number of applications due to its favourable environmental and thermophysical properties. Previous work on residential CO{sub 2} heat pumps has been dealing with systems for either space heating or hot water heating, and it was therefore considered interesting to carry out a theoretical and experimental study of residential CO{sub 2} heat pump systems for combined space heating and hot water heating - o-called integrated CO{sub 2} heat pump systems. The scope of this thesis is limited to brine-to-water and water-to-water heat pumps connected to low-temperature hydronic space heating systems. The main conclusions are: (1) Under certain conditions residential CO{sub 2} heat pump systems for combined space heating and hot water heating may achieve the same or higher seasonal performance factor (SPF) than the most energy efficient state-of-the-art brine-to-water heat pumps. (2) In contrary to conventional heat pump systems for combined space heating and DHW heating, the integrated CO{sub 2} heat pump system achieves the highest COP in the combined heating mode and the DHW heating mode, and the lowest COP in the space heating mode. Hence, the larger the annual DHW heating demand, the higher the SPF of the integrated CO{sub 2} heat pump system. (3) The lower the return temperature in the space heating system and the lower the DHW storage temperature, the higher the COP of the integrated CO{sub 2} heat pump. A low return temperature in the space heating system also results in a moderate DHW heating capacity ratio, which means that a relatively large part of the annual space heating demand can be covered by operation in the combined heating mode, where the COP is considerably higher than in the space heating mode. (4) During operation in the combined heating mode and the DHW heating mode, the COP of the integrated CO{sub 2} heat pump is heavily influenced by

  15. District heating and combined heat and power generation from biomass

    International Nuclear Information System (INIS)

    Veski, Rein

    1999-01-01

    An Altener programme seminar District Heating and Combined Heat and Power Generation from Biomass. Minitraining seminar and study tours and also Business forum, Exhibition and Short company presentations were held in Tallinn on March 21-23, 1999. The Seminar was organised by the VTT Energy, the Estonian Bioenergy Association and the Estonian Heat and Power Association in co-operation with the AFB-net. The Agricultural and Forestry Biomass Network (AFB-net) is part of the ALTENER programme. The Network aims at promoting and stimulating the implementation and commercial utilisation of energy from biomass and waste, through the initiation of business opportunities. This includes national and international co-operation and the exchange of the personnel. The Seminar was attended by consulting companies, scientists, municipal authorities and representatives of co-ordinating bodies engaged in renewable energy management as well as DH and CHP plant managers, equipment manufacturers and local energy planners from Finland, Estonia, Latvia, Lithuania, Sweden, Denmark, Belgium, Slovenia and Slovak Republic. At the Seminar minitraining issues were dealt with: the current situation and future trends in biomass DH in the Baltic Sea countries, and biomass DH and CHP in Eastern and Central Europe, planning and construction of biomass-based DH plants, biomass fuel procurement and handling technology, combustion technology, DH networks, financing of biomass projects and evaluating of projects, and case projects in Eastern and Central European countries. The following were presented: boilers with a capacity of 100 kW or more, stoker burners, wood and straw handling equipment, wood fuel harvesters, choppers, pelletisers, district heating pipelines and networks. (author)

  16. Heat strain and gross efficiency during endurance exercise after lower, upper, or whole body precooling in the heat

    NARCIS (Netherlands)

    Daanen, H. A.; van Es, E.M.; De Graaf, J. L.

    The maximal power that muscles can generate is reduced at low muscle temperatures. However, in prolonged heavy exercise in the heat, a high core temperature may be the factor limiting performance. Precooling has been shown to delay the attainment of hyperthermia. It is still unclear if the whole

  17. Fundamental Study of a Combined Hyperthermia System with RF Capacitive Heating and Interstitial Heating

    OpenAIRE

    Saitoh, Yoshiaki; Hori, Junichi; 斉藤, 義明; 堀, 潤一

    2001-01-01

    Interstitial RF heating with an inserted electrode allows the heating position selection in a subject, but the narrow heating region is problematic. This study elucidates development of new interstitial RF heating methods, combining with external RF heating using paired electrodes, heating the subject broadly in advance in order to selectively extend the heating region. Two kinds of heating system were developed by controlling a differential mode and a common mode of RF currents. Heating expe...

  18. Combined Steady-State and Dynamic Heat Exchanger Experiment

    Science.gov (United States)

    Luyben, William L.; Tuzla, Kemal; Bader, Paul N.

    2009-01-01

    This paper describes a heat-transfer experiment that combines steady-state analysis and dynamic control. A process-water stream is circulated through two tube-in-shell heat exchangers in series. In the first, the process water is heated by steam. In the second, it is cooled by cooling water. The equipment is pilot-plant size: heat-transfer areas…

  19. Integrated multiscale simulation of combined heat and power based district heating system

    International Nuclear Information System (INIS)

    Li, Peifeng; Nord, Natasa; Ertesvåg, Ivar Ståle; Ge, Zhihua; Yang, Zhiping; Yang, Yongping

    2015-01-01

    Highlights: • Simulation of power plant, district heating network and heat users in detail and integrated. • Coupled calculation and analysis of the heat and pressure losses of the district heating network. • District heating is not preferable for very low heat load due to relatively high heat loss. • Lower design supply temperatures of the district heating network give higher system efficiency. - Abstract: Many studies have been carried out separately on combined heat and power and district heating. However, little work has been done considering the heat source, the district heating network and the heat users simultaneously, especially when it comes to the heating system with large-scale combined heat and power plant. For the purpose of energy conservation, it is very important to know well the system performance of the integrated heating system from the very primary fuel input to the terminal heat users. This paper set up a model of 300 MW electric power rated air-cooled combined heat and power plant using Ebsilon software, which was validated according to the design data from the turbine manufacturer. Then, the model of heating network and heat users were developed based on the fundamental theories of fluid mechanics and heat transfer. Finally the combined heat and power based district heating system was obtained and the system performances within multiscale scope of the system were analyzed using the developed Ebsilon model. Topics with regard to the heat loss, the pressure drop, the pump power consumption and the supply temperatures of the district heating network were discussed. Besides, the operational issues of the integrated system were also researched. Several useful conclusions were drawn. It was found that a lower design primary supply temperature of the district heating network would give a higher seasonal energy efficiency of the integrated system throughout the whole heating season. Moreover, it was not always right to relate low design

  20. News from heat-pump research - Large-scale heat pumps, components, heat pumps and solar heating; News aus der Waermepumpen-Forschung - Gross-Waermepumpen, Komponenten, Waermepumpe und Solar

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2010-06-15

    These proceedings summarise the presentations made at the 16{sup th} annual meeting held by the Swiss Federal Office of Energy's Heat Pump Research Program in Burgdorf, Switzerland. The proceedings include contributions on large-scale heat pumps, components and the activities of the heat pump promotion society. A summary of targets and trends in energy research in general is presented and an overview of the heat pump market in 2009 and future perspectives is given. International work within the framework of the International Energy Agency's heat pump group is reviewed, including solar - heat pump combinations. Field-monitoring and the analysis of large-scale heat pumps are discussed and the importance of the use of correct concepts in such installations is stressed. Large-scale heat pumps with carbon dioxide as working fluid are looked at, as are output-regulated air/water heat pumps. Efficient system solutions with heat pumps used both to heat and to cool are discussed. Deep geothermal probes and the potential offered by geothermal probes using carbon dioxide as a working fluid are discussed. The proceedings are rounded off with a list of useful addresses.

  1. Gross Morphology and Localization of Adenohypophyseal Cells in Camel (Camelus dromedarius Using A New Combination of Stains

    Directory of Open Access Journals (Sweden)

    S. A. S. Jaspal, Z. U. Rahman* and A. M. Cheema

    2011-01-01

    Full Text Available Thirty normal camels (Camelus dromedarius were selected for gross morphological and modified staining of anterior pituitary. Camels were divided in three age groups viz 2-4, 5-10 and above 10 years. Pituitary weight, length, width and circumference were recorded before preservation and at midsegittal cutting. Pituitary weight increased significantly as these animals grew older. Male had heavier pituitary as compared to female. Higher pituitary weight was observed in old as compared to young camel. Sections (4m of camel pituitary gland were stained with “Phosphotungstic acid haematoxylin-Orange G-Acid fuchsin-Light green” combination of dyes. This combination of acidic and basic dyes showed affinity to their respective adenohypophyseal cells and proved a suitable combination for differentiation of adenohypophyseal cells and architectural pattern of pituitary gland. Use of Lugol’s Iodine and sodium thiosulphate solution caused mercury fixation which ultimately enhanced the staining of camel adenohypophysis. The whole pituitary presented a brilliant appearance of clarity, enabling cell counts to be performed easily, purely with reference to the colors of adenohypophyseal cell types. This method can be applied for differential staining of adenohypophysis and with good cytology results to the hypophysis of many mammals. The method also provides a sharp contrast between cellular and connective tissue components. With this staining technique, the quantitative and qualitative characteristics of different adenohypophyseal cell types at various functional and hormonal stages, under certain physiological and pathological conditions can also be studied.

  2. Combined convective heat transfer from short cylinders

    International Nuclear Information System (INIS)

    Oosthuizen, P.H.; Paul, J.T.

    1985-01-01

    Considerable experimental evidence has been produced recently showing that the free convective heat transfer rate from horizontal circular cylinders becomes influenced by the length to diameter ratio L/D. The major aim of the present study was to determine the influence of the L/D ratio on the conditions under which buoyancy forces cause the heat transfer rate to start to deviate significantly from that existing in purely forced convection

  3. Effects of the distribution density of a biomass combined heat and power plant network on heat utilisation efficiency in village-town systems.

    Science.gov (United States)

    Zhang, Yifei; Kang, Jian

    2017-11-01

    The building of biomass combined heat and power (CHP) plants is an effective means of developing biomass energy because they can satisfy demands for winter heating and electricity consumption. The purpose of this study was to analyse the effect of the distribution density of a biomass CHP plant network on heat utilisation efficiency in a village-town system. The distribution density is determined based on the heat transmission threshold, and the heat utilisation efficiency is determined based on the heat demand distribution, heat output efficiency, and heat transmission loss. The objective of this study was to ascertain the optimal value for the heat transmission threshold using a multi-scheme comparison based on an analysis of these factors. To this end, a model of a biomass CHP plant network was built using geographic information system tools to simulate and generate three planning schemes with different heat transmission thresholds (6, 8, and 10 km) according to the heat demand distribution. The heat utilisation efficiencies of these planning schemes were then compared by calculating the gross power, heat output efficiency, and heat transmission loss of the biomass CHP plant for each scenario. This multi-scheme comparison yielded the following results: when the heat transmission threshold was low, the distribution density of the biomass CHP plant network was high and the biomass CHP plants tended to be relatively small. In contrast, when the heat transmission threshold was high, the distribution density of the network was low and the biomass CHP plants tended to be relatively large. When the heat transmission threshold was 8 km, the distribution density of the biomass CHP plant network was optimised for efficient heat utilisation. To promote the development of renewable energy sources, a planning scheme for a biomass CHP plant network that maximises heat utilisation efficiency can be obtained using the optimal heat transmission threshold and the nonlinearity

  4. Prototype solar heating and combined heating and cooling systems. Quarterly report No. 6

    Energy Technology Data Exchange (ETDEWEB)

    1978-01-06

    The General Electric Company is developing eight prototype solar heating and combined heating and cooling systems. This effort includes development, manufacture, test, installation, maintenance, problem resolution, and performance evaluation.

  5. Simulation of olive grove gross primary production by the combination of ground and multi-sensor satellite data

    Science.gov (United States)

    Brilli, L.; Chiesi, M.; Maselli, F.; Moriondo, M.; Gioli, B.; Toscano, P.; Zaldei, A.; Bindi, M.

    2013-08-01

    We developed and tested a methodology to estimate olive (Olea europaea L.) gross primary production (GPP) combining ground and multi-sensor satellite data. An eddy-covariance station placed in an olive grove in central Italy provided carbon and water fluxes over two years (2010-2011), which were used as reference to evaluate the performance of a GPP estimation methodology based on a Monteith type model (modified C-Fix) and driven by meteorological and satellite (NDVI) data. A major issue was related to the consideration of the two main olive grove components, i.e. olive trees and inter-tree ground vegetation: this issue was addressed by the separate simulation of carbon fluxes within the two ecosystem layers, followed by their recombination. In this way the eddy covariance GPP measurements were successfully reproduced, with the exception of two periods that followed tillage operations. For these periods measured GPP could be approximated by considering synthetic NDVI values which simulated the expected response of inter-tree ground vegetation to tillages.

  6. Indoor temperatures for calculating room heat loss and heating capacity of radiant heating systems combined with mechanical ventilation systems

    DEFF Research Database (Denmark)

    Wu, Xiaozhou; Olesen, Bjarne W.; Fang, Lei

    2016-01-01

    In this study, a typical office room with a radiant heating system and a mechanical ventilation system was selected as the research subject. Indoor temperature formulas for calculating the room heat loss (including transmission heat loss and ventilation heat loss) and heating capacity of the hybrid...... for calculating ventilation heat loss and heating capacity of radiant heating systems combined with mechanical ventilation systems. (C) 2015 Elsevier B.V. All rights reserved....... change rates on the indoor temperatures were performed using the proposed model. When heated surface temperatures and air change rates were from 21.0 to 29.0 degrees C and from 0.5 to 4.0 h-1, the indoor temperatures for calculating the transmission heat loss and ventilation heat loss were between 20...

  7. Micro-Combined Heat and Power Device Test Facility

    Data.gov (United States)

    Federal Laboratory Consortium — NIST has developed a test facility for micro-combined heat and power (micro-CHP) devices to measure their performance over a range of different operating strategies...

  8. Retrofitting Combined Space and Water Heating Systems. Laboratory Tests

    Energy Technology Data Exchange (ETDEWEB)

    Schoenbauer, B. [NorthernStar Building America Partnership, St. Paul, MN (United States); Bohac, D. [NorthernStar Building America Partnership, St. Paul, MN (United States); Huelman, P. [NorthernStar Building America Partnership, St. Paul, MN (United States); Olsen, R. [NorthernStar Building America Partnership, St. Paul, MN (United States); Hewett, M. [NorthernStar Building America Partnership, St. Paul, MN (United States)

    2012-10-01

    Better insulated and tighter homes can often use a single heating plant for both space and domestic water heating. These systems, called dual integrated appliances (DIA) or combination systems, can operate at high efficiency and eliminate combustion safety issues associated by using a condensing, sealed combustion heating plant. Funds were received to install 400 DIAs in Minnesota low-income homes. The NorthernSTAR DIA laboratory was created to identify proper system components, designs, operating parameters, and installation procedures to assure high efficiency of field installed systems. Tests verified that heating loads up to 57,000 Btu/hr can be achieved with acceptable return water temperatures and supply air temperatures.

  9. Retrofitting Combined Space and Water Heating Systems: Laboratory Tests

    Energy Technology Data Exchange (ETDEWEB)

    Schoenbauer, B.; Bohac, D.; Huelman, P.; Olson, R.; Hewitt, M.

    2012-10-01

    Better insulated and tighter homes can often use a single heating plant for both space and domestic water heating. These systems, called dual integrated appliances (DIA) or combination systems, can operate at high efficiency and eliminate combustion safety issues associated by using a condensing, sealed combustion heating plant. Funds were received to install 400 DIAs in Minnesota low-income homes. The NorthernSTAR DIA laboratory was created to identify proper system components, designs, operating parameters, and installation procedures to assure high efficiency of field installed systems. Tests verified that heating loads up to 57,000 Btu/hr can be achieved with acceptable return water temperatures and supply air temperatures.

  10. Modelling the viability of heat recovery from combined sewers.

    Science.gov (United States)

    Abdel-Aal, M; Smits, R; Mohamed, M; De Gussem, K; Schellart, A; Tait, S

    2014-01-01

    Modelling of wastewater temperatures along a sewer pipe using energy balance equations and assuming steady-state conditions was achieved. Modelling error was calculated, by comparing the predicted temperature drop to measured ones in three combined sewers, and was found to have an overall root mean squared error of 0.37 K. Downstream measured wastewater temperature was plotted against modelled values; their line gradients were found to be within the range of 0.9995-1.0012. The ultimate aim of the modelling is to assess the viability of recovering heat from sewer pipes. This is done by evaluating an appropriate location for a heat exchanger within a sewer network that can recover heat without impacting negatively on the downstream wastewater treatment plant (WWTP). Long sewers may prove to be more viable for heat recovery, as heat lost can be reclaimed before wastewater reaching the WWTP.

  11. Combined electric heating system for timber frame houses

    Directory of Open Access Journals (Sweden)

    Igor Yu. Shelekhov

    2017-06-01

    Full Text Available Introduction: The article presents an overview of the factors affecting the decrease in energy costs during the construction and operation of frame type buildings. The authors propose the methods to increase energy efficiency in heating of frame type buildings. Materials and Methods: The experiment was conducted in an individual residential building with a total area of 80 square meters. Two panels with an infrared heating element and thermoelectric temperature sensors were used. Signals from the sensors were registered by measuring instruments. The amount of the consumed energy was measured by the electric meter. Results: The article identifies the problem and researches of parameters of the combined electric heating system, mutual influence of the two heating devices which are made on the basis of the heating elements with a positive temperature coefficient of resistance. The authors considered the basic scenario, and change of microclimate parameters. They studied the changes of microclimate parameters in the penetration of cold airflows into the room through the opening, and when the temperature of the walls decreases. Discussion and Conclusions: The heating unit using the effect of self-regulation reduces the time for establishing the stationary regime. It helps to reduce the inertia of the heating system and to promote rapid recovery of the microclimate parameters, reducing energy costs and heat loss.

  12. Application of process integration to utilities, combined heat and power, and heat pumps

    Science.gov (United States)

    1989-04-01

    This Data Item 89001, an addition to the Heat Transfer Subseries, shows how the techniques of process integration introduced in ESDU 87030, where they were used to optimize heat exchanger networks, can be extended to design optimally the heat and power systems of a process plant or site. After briefly describing the thermodynamic principles of heating and cooling systems, the various types of heat engines and heat pumps that may be used are introduced, and criteria for their selection to achieve an optimal combined heat and power system are explained. Heat engines include steam and gas turbines and diesel engines, while heat pumps cover mechanical and thermal vapor recompression, refrigeration cycles, and heat transformers. The optimization process covers not only the selection of an appropriate type of utility of the correct size, but also its placement within the process. The application of the techniques is illustrated using the real case study also used in ESDU 87030, and further case studies using current economic and numerical data extend the user's appreciation of the methods.

  13. The capacity credit of micro-combined heat and power

    International Nuclear Information System (INIS)

    Hawkes, A.D.; Leach, M.A.

    2008-01-01

    This article is concerned with development of a methodology to determine the capacity credit of micro-combined heat and power (micro-CHP), and application of the method for the UK. Capacity credit is an important parameter in electricity system planning because it measures the amount of conventional generation that would be displaced by an alternative technology. Firstly, a mathematical formulation is presented. Capacity credit is then calculated for three types of micro-CHP units-Stirling engine, internal combustion engine, and fuel cell systems-operating under various control strategies. It is found that low heat-to-power ratio fuel cell technologies achieve the highest capacity credit of approximately 85% for a 1.1 GW penetration when a heat-led control strategy is applied. Higher heat-to-power ratio Stirling engine technology achieves approximately 33% capacity credit for heat-led operation. Low heat-to-power ratio technologies achieve higher capacity credit because they are able to continue operating even when heat demand is relatively low. Capacity credit diminishes as penetration of the technology increases. Overall, the high capacity credit of micro-CHP contributes to the viewpoint that the technology can help meet a number of economic and environmental energy policy aims

  14. Irradiation in combination of heat treatment of mango puree

    International Nuclear Information System (INIS)

    Noomhorm, A.; Apintanapong, M.

    1996-01-01

    The effect of irradiation with heat combination treatment on the shelf life and quality of mango puree was studied. Thermal inactivation of polyphenol oxidase enzyme at 80 degree C and 15 min. was used as a measure of adequacy of pre-heat treatment. Irradiation of mango puree after heat treatment at dosage of 0, 2, 4, 6 and 8 kGy showed no change in mc, pH, acidity, and TSS but during storage, growth of microorganisms brought changes in these values. Irradiation in combination with low temperature (5 degree C) reduced discoloration and darkening rate during storage. Irradiation dose from 0 to 8 kGy resulted in log linear reductions in microorganism levels but at 6 and 8 kGy, there was no growth of microorganisms. Products irradiated at 8 kGy showed no microorganism growth at both temperatures

  15. Measure Guideline: Combined Space and Water Heating Installation and Optimization

    Energy Technology Data Exchange (ETDEWEB)

    Schoenbauer, B. [NorthernSTAR Building America Partnership, St. Paul, MN (United States); Bohac, D. [NorthernSTAR Building America Partnership, St. Paul, MN (United States); Huelman, P. [NorthernSTAR Building America Partnership, St. Paul, MN (United States)

    2017-03-01

    Combined space and water heater (combi or combo) systems are defined by their dual functionality. Combi systems provide both space heating and water heating capabilities with a single heat source. This guideline will focus on the installation and operation of residential systems with forced air heating and domestic hot water (DHW) functionality. Past NorthernSTAR research has used a combi system to replace a natural gas forced air distribution system furnace and tank type water heater (Schoenbauer et al. 2012; Schoenbauer, Bohac, and McAlpine 2014). The combi systems consisted of a water heater or boiler heating plant teamed with a hydronic air handler that included an air handler, water coil, and water pump to circulate water between the heating plant and coil. The combi water heater or boiler had a separate circuit for DHW. Past projects focused on laboratory testing, field characterization, and control optimization of combi systems. Laboratory testing was done to fully characterize and test combi system components; field testing was completed to characterize the installed performance of combi systems; and control methodologies were analyzed to understand the potential of controls to simplify installation and design and to improve system efficiency and occupant comfort. This past work was relied upon on to create this measure guideline.

  16. Measure Guideline: Combined Space and Water Heating Installation and Optimization

    Energy Technology Data Exchange (ETDEWEB)

    Schoenbauer, B. [Univ. of Minnesota, St. Paul, MN (United States). NorthernSTAR Building America Partnership; Bohac, D. [Univ. of Minnesota, St. Paul, MN (United States). NorthernSTAR Building America Partnership; Huelman, P. [Univ. of Minnesota, St. Paul, MN (United States). NorthernSTAR Building America Partnership

    2017-03-03

    Combined space and water heater (combi or combo) systems are defined by their dual functionality. Combi systems provide both space heating and water heating capabilities with a single heat source. This guideline will focus on the installation and operation of residential systems with forced air heating and domestic hot water (DHW) functionality. Past NorthernSTAR research has used a combi system to replace a natural gas forced air distribution system furnace and tank type water heater (Schoenbauer et al. 2012; Schoenbauer, Bohac, and McAlpine 2014). The combi systems consisted of a water heater or boiler heating plant teamed with a hydronic air handler that included an air handler, water coil, and water pump to circulate water between the heating plant and coil. The combi water heater or boiler had a separate circuit for DHW. Past projects focused on laboratory testing, field characterization, and control optimization of combi systems. Laboratory testing was done to fully characterize and test combi system components; field testing was completed to characterize the installed performance of combi systems; and control methodologies were analyzed to understand the potential of controls to simplify installation and design and to improve system efficiency and occupant comfort. This past work was relied upon on to create this measure guideline.

  17. An investigation of energy efficient and sustainable heating systems for buildings : Combining photovoltaics with heat pump

    OpenAIRE

    Hesaraki, Arefeh; Holmberg, Sture

    2013-01-01

    Renewable energy sources contribute considerable amounts of energy when natural phenomena are converted into useful forms of energy. Solar energy, i.e. renewable energy, is converted to electricity by photovoltaic systems (PV). This study was aimed at investigating the possibility of combining PV with Heat Pump (HP) (PV-HP system). HP uses direct electricity to produce heat. In order to increase the sustainability and efficiency of the system, the required electricity for the HP was supposed ...

  18. Combination study of operation characteristics and heat transfer mechanism for pulsating heat pipe

    International Nuclear Information System (INIS)

    Cui, Xiaoyu; Zhu, Yue; Li, Zhihua; Shun, Shende

    2014-01-01

    Pulsating heat pipe (PHP) is becoming a promising heat transfer device for the application like electronics cooling. However, due to its complicated operation mechanism, the heat transfer properties of the PHP still have not been fully understood. This study experimentally investigated on a closed-loop PHP charged with four types of working fluids, deionized water, methanol, ethanol and acetone. Combined with the visualization experimental results from the open literature, the operation characteristics and the corresponding heat transfer mechanisms for different heat inputs (5 W up to 100 W) and different filling ratios (20% up to 95%) have been presented and elaborated. The results show that heat-transfer mechanism changed with the transition of operation patterns; before valid oscillation started, the thermal resistance was not like that described in the open literature where it decreased almost linearly, but would rather slowdown descending or even change into rise first before further decreasing (i.e. an inflection point existed); when the heat input further increased to certain level, e.g. 65 W or above, there presented a limit of heat-transfer performance which was independent of the types of working fluids and the filling ratios, but may be related to the structure, the material, the size and the inclination of the PHP. - Highlights: •The thermal mechanisms altered accordingly with the operation features in the PHP. •Unlike conventional heat pipes, continuous temperature soaring would not happen in the PHP. •Before the oscillation start-up, there existed a heat-transfer limit for the relatively stagnated flow in the PHP. •A limit of thermal performance existed in the PHP at relatively high heat inputs

  19. Investigation of a heat storage for a solar heating system for combined space heating and domestic hot water supply for homeowner´s association "Bakken"

    DEFF Research Database (Denmark)

    Vejen, Niels Kristian

    1998-01-01

    A heat storage for a solar heating system for combined space heating and domestic hot water supply was tested in a laboratory test facility.The heat storage consist of a mantle tank with water for the heating system and of a hot water tank, which by means of thermosyphoning is heated by the water...... in the heating system. The heat storage was tested in a heat storage test facility. The most important characteristics of the heat storage were determined by means of the tests and recommendations for the design of the heat storage were given....

  20. Combined Heat and Power in an open market

    International Nuclear Information System (INIS)

    Hawkins, A.

    1999-01-01

    The chances and risks for combined heat and power (CHP) installations presented by the future liberalisation of the electricity market in Switzerland are discussed. A summary of papers and speeches presented at a conference in Basle is presented. New developments in the electricity marketplace are looked at from the point of view of CHP unit manufacturers, the Federal Administration, energy policy makers and marketing experts. Examples are quoted concerning the situation in Germany and possible changes in power generation philosophy

  1. A feasible system integrating combined heating and power system with ground-source heat pump

    International Nuclear Information System (INIS)

    Li, HongQiang; Kang, ShuShuo; Yu, Zhun; Cai, Bo; Zhang, GuoQiang

    2014-01-01

    A system integrating CHP (combined heating and power) subsystem based on natural gas and GSHP (ground-source heat pump subsystem) in series is proposed. By help of simulation software-Aspen Plus, the energy performance of a typical CHP and GSHP-S (S refers to ‘in series’) system was analyzed. The results show that the system can make a better use of waste heat in flue gas from CHP (combined heating and power subsystem). The total system energy efficiency is 123% and the COP (coefficient of performance) of GSHP (ground-source heat pump) subsystem is 5.3. A referenced CHP and GSHP-P (P refers to ‘in parallel’) system is used for comparison; its total system energy efficiency and COP of GSHP subsystem are 118.6% and 3.5 respectively. Compared with CHP and GSHP-P system with different operating parameters, the CHP and GSHP-S system can increase total system energy efficiency by 0.8–34.7%, with related output ratio of heat to power (R) from 1.9 to 18.3. Furthermore, the COP of GSHP subsystem can be increased between the range 3.6 and 6, which is much higher than that in conventional CHP and GSHP-P system. This study will be helpful for other efficient GSHP systems integrating if there is waste heat or other heat resources with low temperature. - Highlights: • CHP system based on natural gas and ground source heat pump. • The new system can make a better utilization of waste heat in flue gas by a special way. • The proposed system can realize energy saving potential from 0.8 to 34.7%. • The coefficient of performance of ground source heat pump subsystem is significantly improved from 3.5 to 3.6–6. • Warm water temperature and percentage of flue gas used to reheat are key parameters

  2. Gross mechanical efficiency of the combined arm-leg (Cruiser) ergometer : a comparison with the bicycle ergometer and handbike

    NARCIS (Netherlands)

    Simmelink, Elisabeth K.; Borgesius, Emilie C.; Hettinga, Florentina J.; Geertzen, Joannes; Dekker, Rienk; van der Woude, Lucas H. V.

    The combined arm-leg (Cruiser) ergometer is assumed to be a relevant testing and training instrument in the rehabilitation of patients with a lower limb amputation. The efficiency and submaximal strain have not been established and thus cannot be compared with alternative common modes of exercise. A

  3. Thermal Energy Corporation Combined Heat and Power Project

    Energy Technology Data Exchange (ETDEWEB)

    Turner, E. Bruce [Thermal Energy Corporation, Houston, TX (United States); Brown, Tim [Thermal Energy Corporation, Houston, TX (United States); Mardiat, Ed [Burns and McDonnell Engineering Company, Inc., Kansas City, MI (United States)

    2011-12-31

    To meet the planned heating and cooling load growth at the Texas Medical Center (TMC), Thermal Energy Corporation (TECO) implemented Phase 1 of a Master Plan to install an additional 32,000 tons of chilled water capacity, a 75,000 ton-hour (8.8 million gallon) Thermal Energy Storage (TES) tank, and a 48 MW Combined Heat and Power (CHP) system. The Department of Energy selected TMC for a $10 million grant award as part of the Financial Assistance Funding Opportunity Announcement, U.S. Department of Energy National Energy Technology, Recovery Act: Deployment of Combined Heat and Power (CHP) Systems, District Energy Systems, Waste Energy Recovery Systems, and Efficiency Industrial Equipment Funding Opportunity Number: DE-FOA-0000044 to support the installation of a new 48 MW CHP system at the TMC located just outside downtown Houston. As the largest medical center in the world, TMC is home to many of the nation's best hospitals, physicians, researchers, educational institutions, and health care providers. TMC provides care to approximately six million patients each year, and medical instruction to over 71,000 students. A medical center the size of TMC has enormous electricity and thermal energy demands to help it carry out its mission. Reliable, high-quality steam and chilled water are of utmost importance to the operations of its many facilities. For example, advanced medical equipment, laboratories, laundry facilities, space heating and cooling all rely on the generation of heat and power. As result of this project TECO provides this mission critical heating and cooling to TMC utilizing a system that is both energy-efficient and reliable since it provides the capability to run on power independent of the already strained regional electric grid. This allows the medical center to focus on its primary mission providing top quality medical care and instruction without worrying about excessive energy costs or the loss of heating and cooling due to the risk of power

  4. Combined Space and Water Heating: Next Steps to Improved Performance

    Energy Technology Data Exchange (ETDEWEB)

    Schoenbauer, B. [NorthernSTAR Building America Partnership, Minneapolis, MN (United States); Bohac, D. [NorthernSTAR Building America Partnership, Minneapolis, MN (United States); Huelman, P. [NorthernSTAR Building America Partnership, Minneapolis, MN (United States)

    2016-07-13

    A combined space- and water-heating (combi) system uses a high-efficiency direct-vent burner that eliminates safety issues associated with natural draft appliances. Past research with these systems shows that using condensing water heaters or boilers with hydronic air handling units can provide both space and water heating with efficiencies of 90% or higher. Improved controls have the potential to reduce complexity and improve upon the measured performance. This project demonstrates that controls can significantly benefit these first-generation systems. Laboratory tests and daily load/performance models showed that the set point temperature reset control produced a 2.1%-4.3% (20-40 therms/year) savings for storage and hybrid water heater combi systems operated in moderate-load homes.

  5. WORKING PARK-FUEL CELL COMBINED HEAT AND POWER SYSTEM

    Energy Technology Data Exchange (ETDEWEB)

    Allan Jones

    2003-09-01

    This report covers the aims and objectives of the project which was to design, install and operate a fuel cell combined heat and power (CHP) system in Woking Park, the first fuel cell CHP system in the United Kingdom. The report also covers the benefits that were expected to accrue from the work in an understanding of the full technology procurement process (including planning, design, installation, operation and maintenance), the economic and environmental performance in comparison with both conventional UK fuel supply and conventional CHP and the commercial viability of fuel cell CHP energy supply in the new deregulated energy markets.

  6. Combined Heat and Power Market Potential for Opportunity Fuels

    Energy Technology Data Exchange (ETDEWEB)

    Jones, David [Resource Dynamics Corporation, McLean, VA (United States); Lemar, Paul [Resource Dynamics Corporation, McLean, VA (United States

    2015-12-01

    This report estimates the potential for opportunity fuel combined heat and power (CHP) applications in the United States, and provides estimates for the technical and economic market potential compared to those included in an earlier report. An opportunity fuel is any type of fuel that is not widely used when compared to traditional fossil fuels. Opportunity fuels primarily consist of biomass fuels, industrial waste products and fossil fuel derivatives. These fuels have the potential to be an economically viable source of power generation in various CHP applications.

  7. Cost-benefit analysis for combined heat and power plant

    International Nuclear Information System (INIS)

    Sazdovski, Ace; Fushtikj, Vangel

    2004-01-01

    The paper presents a methodology and practical application of Cost-Benefit Analysis for Combined Heat and Power Plant (Cogeneration facility). Methodology include up-to-date and real data for cogeneration plant in accordance with the trends ill development of the CHP technology. As a case study a CHP plant that could be built-up in Republic of Macedonia is analyzed. The main economic parameters for project evaluation, such as NPV and IRR are calculated for a number of possible scenarios. The analyze present the economic outputs that could be used as a decision for CHP project acceptance for investment. (Author)

  8. Gross motor control

    Science.gov (United States)

    Gross motor control is the ability to make large, general movements (such as waving an arm or lifting a ... Gross motor control is a milestone in the development of an infant. Infants develop gross motor control before they ...

  9. Temperate Performance Benefits after Heat, but Not Combined Heat and Hypoxic Training.

    Science.gov (United States)

    McCleave, Erin L; Slattery, Katie M; Duffield, Rob; Saunders, Philo U; Sharma, Avish P; Crowcroft, Stephen J; Coutts, Aaron J

    2017-03-01

    Independent heat and hypoxic exposure can enhance temperate endurance performance in trained athletes, although their combined effects remain unknown. This study examined whether the addition of heat interval training during "live high, train low" (LHTL) hypoxic exposure would result in enhanced performance and physiological adaptations as compared with heat or temperate training. Twenty-six well-trained runners completed 3 wk of interval training assigned to one of three conditions: 1) LHTL hypoxic exposure plus heat training (H + H; 3000 m for 13 h·d, train at 33°C, 60% relative humidity [RH]), 2) heat training with no hypoxic exposure (HOT, live at train at 33°C, 60% RH), or 3) temperate training with no hypoxic exposure (CONT; live at train at 14°C, 55% RH). Performance 3-km time-trials (3-km TT), running economy, hemoglobin mass, and plasma volume were assessed using magnitude-based inferences statistical approach before (Baseline), after (Post), and 3 wk (3wkP) after exposure. Compared with Baseline, 3-km TT performance was likely increased in HOT at 3wkP (-3.3% ± 1.3%; mean ± 90% confidence interval), with no performance improvement in either H + H or CONT. Hemoglobin mass increased by 3.8% ± 1.8% at Post in H + H only. Plasma volume in HOT was possibly elevated above H + H and CONT at Post but not at 3wkP. Correlations between changes in 3-km TT performance and physiological adaptations were unclear. Incorporating heat-based training into a 3-wk training block can improve temperate performance at 3 wk after exposure, with athlete psychology, physiology, and environmental dose all important considerations. Despite hematological adaptations, the addition of LHTL to heat interval training has no greater 3-km TT performance benefit than temperate training alone.

  10. Combined NMR moisture, temperature and pressure measurements during heating

    Directory of Open Access Journals (Sweden)

    Pel L.

    2013-09-01

    Full Text Available For model validation, quantitative measurements of the evolution of moisture, temperature, and pressure distributions in time are needed. For this purpose, we have developed an NMR setup to measure the moisture transport in heated building materials. The measured combined moisture content and temperature profiles give a unique insight in the moisture transport and dehydration kinetics inside concrete during fire. These measurements give the first quantitative proof for the build-up of a moisture peak due to the vapor pressure build-up. In this study we have also combined for the first time the measurement of the moisture and temperature profiles with the measurement of the pressure at one position, which show that the pressure build up is directly related to the moisture profiles.

  11. Application of combined heat and power in Malaysia Industrial Sector

    International Nuclear Information System (INIS)

    Zaredah Hashim; Faridah Mohd Taha

    2010-01-01

    Malaysia is still working on continuing its economic growth especially in the industrial sector in order to achieve vision 2020. The rapid industrialization process has caused increment in the energy demand, which simultaneously increases carbon dioxide (CO 2 ) emissions. Energy efficient technologies are strongly needed for reducing the energy requirement and to avoid the depleting of energy resources. This project focused on the application of integrated resource planning (IRP) in industrial sector using Combined Heat and Power (CHP), as a strategy for Demand Side Management (DSM). This approach is another way for meeting near and future energy requirement in Malaysia's industrial sector. Two scenarios which are Business As Usual (BAU) and CHP were developed using End Use Model EUM), to forecast the energy demand and CO 2 emission in Malaysia's industries. The effectiveness of the proposed method is then simulated using Long Range Energy Alternative Planning System (LEAP) software and Comparative Model for Projects of Engineering Economics and Energy Environmental Development (COMPEED) analysis. Evaluations were based on the potential of energy saving and CO 2 reduction. Scope of research was limited to pulp and paper industrial sub sector. The research data were extracted from Energy Audit Reports conducted by Malaysia Energy Center (PTM). An engineering calculation was demonstrated. Two designs of CHP applications for the pulp and paper industrial sector are according to heating and electricity sizing. It was found that the most energy efficient and CO 2 reduction for Malaysia's industrial sector is the CHP based on heating requirement. The method was found to be able of save fuel and GHG emission compared to the reference case. (author)

  12. Flue gas recovery system for natural gas combined heat and power plant with distributed peak-shaving heat pumps

    International Nuclear Information System (INIS)

    Zhao, Xiling; Fu, Lin; Wang, Xiaoyin; Sun, Tao; Wang, Jingyi; Zhang, Shigang

    2017-01-01

    Highlights: • A flue gas recovery system with distributed peak-shaving heat pumps is proposed. • The system can improve network transmission and distribution capacity. • The system is advantageous in energy saving, emission reduction and economic benefits. - Abstract: District heating systems use distributed heat pump peak-shaving technology to adjust heat in secondary networks of substations. This technology simultaneously adjusts the heat of the secondary network and reduces the return-water temperature of the primary network by using the heat pump principle. When optimized, low temperature return-water is able to recycle more waste heat, thereby further improving the heating efficiency of the system. This paper introduces a flue gas recovery system for a natural gas combined heat and power plant with distributed peak-shaving heat pumps. A pilot system comprising a set of two 9F gas-steam combined cycle-back pressure heating units was used to analyse the system configuration and key parameters. The proposed system improved the network transmission and distribution capacity, increased heating capacity, and reduced heating energy consumption without compromising heating safety issues. As such, the proposed system is advantageous in terms of energy saving, emission reduction, and economic benefits.

  13. Combined Space and Water Heating: Next Steps to Improved Performance

    Energy Technology Data Exchange (ETDEWEB)

    Schoenbauer, B. [NorthernSTAR Building America Partnership, Minneapolis, MN (United States); Bohac, D. [NorthernSTAR Building America Partnership, Minneapolis, MN (United States); Huelman, P. [NorthernSTAR Building America Partnership, Minneapolis, MN (United States)

    2016-07-13

    A combined space- and water-heating (combi) system uses a high-efficiency direct-vent burner that eliminates safety issues associated with natural draft appliances. Past research with these systems shows that using condensing water heaters or boilers with hydronic air handling units can provide both space and water heating with efficiencies of 90% or higher. Improved controls have the potential to reduce complexity and improve upon the measured performance. This project demonstrates that controls can significantly benefit these first-generation systems. Laboratory tests and daily load/performance models showed that the set point temperature reset control produced a 2.1%–4.3% (20–40 therms/year) savings for storage and hybrid water heater combi systems operated in moderate-load homes. The full modulation control showed additional savings over set point control (in high-load homes almost doubling the savings: 4%–5% over the no-control case). At the time of installation the reset control can be implemented for $200–$400, which would provide paybacks of 6–25 years for low-load houses and 3–15 years for high-load houses. Full modulation implementation costs would be similar to the outdoor reset and would provide paybacks of 5-½–20 years for low-load houses and 2-½–10 years for high-load houses.

  14. EFFECT OF VIBRATION AND HEAT COMBINATION ON PRIMARY DYSMENORRHEA

    Directory of Open Access Journals (Sweden)

    M. Hoseini

    2015-03-01

    Full Text Available Background: Primary dysmenorrhoea is a common, idiopathic, chronic pelvic pain syndrome, with unknown aetiology which ‎about 50% of women with regular menstrual period suffer. This study was designed to determine the effect of vibration and heat on primary dysmenorrhea. Materials and Methods: In this clinical trial, 75 female students aged 18-22 years old were evaluated for two menstrual cycles. At the first cycle the participants received the routine pain-relief method (synthetic or herbal medicine and traditional remedies. At the second cycle for each participant combined vibration-heat device was applied for ten minutes during ‎menstrual pain. The average of perceived leg pain, lumbar pain and abdominal pain scores at two cycles were determined. The data were analyzed based on Wilcoxon and T tests by using SPSS (v 16.0 for Windows. Results: The average of all perceived pain scores at two cycles were significantly different before pain relief and after both routine methods and using the device (p<0.001. Those were more significantly reduced after using the device in comparison of using routine methods (p<0.001. Conclusion: Since “vibration-heat” is an effective pain relief method, it can be used as a complementary alternative medicine in primary dysmenorrhea reduction.

  15. Stochastic analysis of residential micro combined heat and power system

    DEFF Research Database (Denmark)

    Karami, H.; Sanjari, M. J.; Gooi, H. B.

    2017-01-01

    In this paper the combined heat and power functionality of a fuel-cell in a residential hybrid energy system, including a battery, is studied. The demand uncertainties are modeled by investigating the stochastic load behavior by applying Monte Carlo simulation. The colonial competitive algorithm...... is adopted to the hybrid energy system scheduling problem and different energy resources are optimally scheduled to have optimal operating cost of hybrid energy system. In order to show the effectiveness of the colonial competitive algorithm, the results are compared with the results of the harmony search...... algorithm. The optimized scheduling of different energy resources is listed in an efficient look-up table for all time intervals. The effects of time of use and the battery efficiency and its size are investigated on the operating cost of the hybrid energy system. The results of this paper are expected...

  16. Combined heat transfer and kinetic models to predict cooking loss during heat treatment of beef meat.

    Science.gov (United States)

    Kondjoyan, Alain; Oillic, Samuel; Portanguen, Stéphane; Gros, Jean-Bernard

    2013-10-01

    A heat transfer model was used to simulate the temperature in 3 dimensions inside the meat. This model was combined with a first-order kinetic models to predict cooking losses. Identification of the parameters of the kinetic models and first validations were performed in a water bath. Afterwards, the performance of the combined model was determined in a fan-assisted oven under different air/steam conditions. Accurate knowledge of the heat transfer coefficient values and consideration of the retraction of the meat pieces are needed for the prediction of meat temperature. This is important since the temperature at the center of the product is often used to determine the cooking time. The combined model was also able to predict cooking losses from meat pieces of different sizes and subjected to different air/steam conditions. It was found that under the studied conditions, most of the water loss comes from the juice expelled by protein denaturation and contraction and not from evaporation. Copyright © 2013 Elsevier Ltd. All rights reserved.

  17. Temporary heat storage by using combined heat and power in supplementary lighted greenhouses Proceedings of the Third International Symposium on Artificial Lighting in Horticulture

    NARCIS (Netherlands)

    Huijs, J.P.G.

    1997-01-01

    Because of better utilization possibilities of the produced heat, decentrally located combined heat and power installations achieve a higher energetic efficiency than producing heat and power separately. However, efficiency depends considerably on synchronism of heat and electricity demand. Using a

  18. Experimental investigation of combined heat recovery and power generation using a heat pipe assisted thermoelectric generator system

    International Nuclear Information System (INIS)

    Remeli, Muhammad Fairuz; Date, Abhijit; Orr, Bradley; Ding, Lai Chet; Singh, Baljit; Affandi, Nor Dalila Nor; Akbarzadeh, Aliakbar

    2016-01-01

    Highlights: • A new passive combined heat recovery and power generation system was tested. • Heat pipes and thermoelectrics were used for recovering industrial waste heat. • The system could recover approximately 1079 W of heat and produce approximately 7 W of electric power. - Abstract: This paper explores a new method of recovering industrial waste heat and conversion to electricity using a Thermo-Electric Generator (TEG). For this purpose, a lab scale bench-top prototype of waste heat recovery and electricity conversion system was designed and fabricated. This bench top system consists of Bismuth Telluride (Bi 2 Te 3 ) based TEG sandwiched between two heat pipes. The first heat pipe was connected to the hot side of the TEG and the second to the cold side of TEG. The waste heat was simulated by using a 2 kW electric heater for heating the air in the system. Experiments were conducted to evaluate the system performance in terms of the heat transfer rate, heat exchanger effectiveness, and maximum output power. It was found that the highest heat exchanger effectiveness of 41% was achieved when the airspeed was set at 1.1 m/s. The system could recover around 1079 W of heat and produce around 7 W of electric power. This equated to 0.7% of thermal-to-electric conversion efficiency. The theoretical predictions showed good agreement compared to the experimental results.

  19. Small-Scale Combined Heat and Power Plants Using Biofuels

    Energy Technology Data Exchange (ETDEWEB)

    Salomon-Popa, Marianne [Royal Inst. of Tech., Stockholm (Sweden). Dept. of Energy Technology

    2002-11-01

    In this time period where energy supply and climate change are of special concern, biomass-based fuels have attracted much interest due to their plentiful supply and favorable environmental characteristics (if properly managed). The effective capture and continued sustainability of this renewable resource requires a new generation of biomass power plants with high fuel energy conversion. At the same time, deregulation of the electricity market offers new opportunities for small-scale power plants in a decentralized scheme. These two important factors have opened up possibilities for small-scale combined heat and power (CHP) plants based on biofuels. The objective of this pre-study is to assess the possibilities and technical limitations for increased efficiency and energy utilization of biofuels in small size plants (approximately 10 MWe or lower). Various energy conversion technologies are considered and proven concepts for large-scale fossil fuel plants are an especially important area. An analysis has been made to identify the problems, technical limitations and different possibilities as recognized in the literature. Beyond published results, a qualitative survey was conducted to gain first-hand, current knowledge from experts in the field. At best, the survey results together with the results of personal interviews and a workshop on the role of small-scale plants in distributed generation will serve a guideline for future project directions and ideas. Conventional and novel technologies are included in the survey such as Stirling engines, combustion engines, gas turbines, steam turbines, steam motors, fuel cells and other novel technologies/cycles for biofuels. State-of-the-art heat and power plants will be identified to clarify of the advantages and disadvantages as well as possible obstacles for their implementation.

  20. Satellite combined heat and power plants and their legal autonomy

    International Nuclear Information System (INIS)

    Loibl, Helmut

    2014-01-01

    Since the landmark decision by the German Court of Justice concerning the term ''plant'' in the context of biogas plants it should be clear beyond doubt that satellite combined heat and power plants (CHPs) are legally autonomous plants pursuant to Para. 3 No. 1 of the Renewable Energy Law (EEG). What has yet to be finally resolved are the conditions under which satellite CHPs are to be regarded as autonomous. This will be a question of distance on the one hand and of operation autonomy on the other. In the individual case both these factors will have to be assessed from the perspective of an average objective, informed citizen. To the extent that its heat and electricity are being utilised in a meaningful manner, the plant's autonomy will be beyond doubt, at least in operational terms. Regarding the remuneration to be paid for satellite CHPs the only case requiring special consideration is when a CHP falls under the EEG of 2012. In this case Para. 1 Section 1 Sentence 2 EEG provides that the remuneration for the CHP in question is to be calculated as if there was a single overall plant. To the extent that none of the CHPs fall under the EEG of 2012, the ruling remains that there is a separate entitlement to remuneration for each satellite CHP. This also holds in cases where satellite CHPs that were commissioned after 1 January 2012 are relocated. When a satellite CHP is replaced by a new one, the rate and duration of remuneration remain unchanged. However, when a new satellite CHP is added to an existing satellite CHP via a gas collector line it is to be treated according to the decisions of the Federal Court of Justice concerning biogas plant extensions: It falls under the law that applies to the existing CHP and has an entitlement to a new minimum remuneration period, albeit subject to the degression rate provided by the EEG version in question.

  1. One-day low-intensity combined arm-leg (Cruiser) ergometer exercise intervention : cardiorespiratory strain and gross mechanical efficiency in one-legged and two-legged exercise

    NARCIS (Netherlands)

    Simmelink, Elisabeth K; Wervelman, Thijs; de Vries, Hendrik S; Geertzen, Jan H B; Dekker, Rienk; van der Woude, Lucas H V

    2017-01-01

    This study aims to research whether there is a difference in cardiorespiratory variables and gross mechanical efficiency (GE) in healthy individuals during low-intensity one-legged and two-legged exercise on the combined arm-leg (Cruiser) ergometer and whether motor learning occurs. The outcome of

  2. Computational heat transfer analysis and combined ANN–GA ...

    Indian Academy of Sciences (India)

    Jones & Smith (1970) studied the optimal arrangement of rectangular fins on horizontal surfaces for free-convection heat transfer for maximum heat trans- fer rate and proposed correlations to obtain optimum fin spacing. Khaled (2010) numerically studied the permissible number of fins for heat transfer enhancement and ...

  3. IMPROVED MANUFACTURING CANNED "COMPOTE CHERRY" USING COMBINED HEAT TREATMENT

    Directory of Open Access Journals (Sweden)

    A. F. Demirova

    2013-01-01

    Full Text Available The results of studies on the development of new modes of heat sterilization compote cherry using stepwise heating in a stream of hot air and hot water dushevaniem air cooled rotating container. Revealed that the modes provide commercial sterility of finished products, reducing the length of the heat treatment and the quality of the finished product. Are some of the modes of heat sterilization step of cherry compote in a stream of heated air and water dushevaniem air-cooled rotating container.

  4. Absorption chillers integration in a combined heat and power plant

    Energy Technology Data Exchange (ETDEWEB)

    Bruno, J. C.; Fernandez, F.; Castells, F. [Barcelona Univ., Tarragona (Spain). Dept. d`Enginyeria Quimica i Bioqumica

    1996-11-01

    Inclusion of an absorption cycle within a combined heat and power plant (CHP) was evaluated. To determine the most suitable configuration of the energy network generation system and absorption chiller, a simulation and optimization model was constructed. To validate the optimization model, a case study using actual data from existing operating plants has been used. In the case described the cooling facilities from the absorption cycle were used to lower the inlet temperature to the compressor of the gas turbine to improve the overall plant efficiency. Waste steam from the steam network was used in the generator of the absorption chiller. A reduction in steam wastes, and an improvement in overall plant efficiency was observed. A simulation model of a single effect absorption chiller, using water-lithium bromide as the working fluid pair, was used to validate the methodology. Results showed that the benefits of integrating the absorption refrigeration cycle (ARC) depends directly on the refrigeration demand, and on the benefit produced by the waste steam recovered. The increase in power generation, allowing a reduction in primary energy consumption, showed a slight economic advantage over the conventional compression cycle. 13 refs., 7. tabs., 6 figs.

  5. Stochastic analysis of residential micro combined heat and power system

    International Nuclear Information System (INIS)

    Karami, H.; Sanjari, M.J.; Gooi, H.B.; Gharehpetian, G.B.; Guerrero, J.M.

    2017-01-01

    Highlights: • Applying colonial competitive algorithm to the problem of optimal dispatching. • Economic modeling of the residential integrated energy system. • Investigating differences of stand-alone and system-connected modes of fuel cell operation. • Considering uncertainty on the electrical load. • The effects of battery capacity and its efficiency on the system is investigated. - Abstract: In this paper the combined heat and power functionality of a fuel-cell in a residential hybrid energy system, including a battery, is studied. The demand uncertainties are modeled by investigating the stochastic load behavior by applying Monte Carlo simulation. The colonial competitive algorithm is adopted to the hybrid energy system scheduling problem and different energy resources are optimally scheduled to have optimal operating cost of hybrid energy system. In order to show the effectiveness of the colonial competitive algorithm, the results are compared with the results of the harmony search algorithm. The optimized scheduling of different energy resources is listed in an efficient look-up table for all time intervals. The effects of time of use and the battery efficiency and its size are investigated on the operating cost of the hybrid energy system. The results of this paper are expected to be used effectively in a real hybrid energy system.

  6. NM Gross Receipts Baseline

    Data.gov (United States)

    Earth Data Analysis Center, University of New Mexico — This layer represents boundaries for New Mexico's gross receipts tax districts as identified on the "Gross Receipts Tax Rate Schedule" published by the Taxation and...

  7. Simulating conditions for combined heat and power in the Swedish district heating sector

    International Nuclear Information System (INIS)

    Knutsson, David

    2005-01-01

    The most important issues in the European energy sector today are how to increase competitiveness on the energy markets, reduce both CO2 emissions and dependence on imported fuels. These issues are also important aspects of Swedish energy policy. In Sweden, the district heating (DH) sector has commonly been used to achieve Swedish energy policy goals. However, the ongoing integration and deregulation of the energy markets in Europe now means that the Swedish DH sector can also play an important role in achieving international targets. This thesis investigates the extent to which the Swedish DH sector can contribute to compliance with current energy policy targets, both international and Swedish. The study consisted of simulations of the Swedish DH sector response to various policy instruments in a model that takes the local features of virtually all Swedish DH systems into account. The findings show, for example, that there is great potential for combined heat and power (CHP) generation in the Swedish DH sector. By exporting this CHP electricity to other European countries with less effective and fossil dependent power generation plants, the CO2 emissions from the European energy sector could be substantially reduced. This would also result in increased security of supply and competitiveness in the EU, since fuel use would be more effective. In Sweden, increased CHP generation would also be a way of maintaining an effective national security of supply of power

  8. Performance characteristics of a combination solar photovoltaic heat engine energy converter

    Science.gov (United States)

    Chubb, Donald L.

    1987-01-01

    A combination solar photovoltaic heat engine converter is proposed. Such a system is suitable for either terrestrial or space power applications. The combination system has a higher efficiency than either the photovoltaic array or the heat engine alone can attain. Advantages in concentrator and radiator area and receiver mass of the photovoltaic heat engine system over a heat-engine-only system are estimated. A mass and area comparison between the proposed space station organic Rankine power system and a combination PV-heat engine system is made. The critical problem for the proposed converter is the necessity for high temperature photovoltaic array operation. Estimates of the required photovoltaic temperature are presented.

  9. Gross National Happiness

    DEFF Research Database (Denmark)

    Giri, Krishna Prasad; Kjær-Rasmussen, Lone Krogh

    This paper investigates practices related to the ideology of infusing Gross National Happiness (GNH) into school curriculum, the effectiveness of the meditation and mind training and the implication of GNH for school environment. It also explores how GNH ambience has been managed and practiced...... of Gross National Happiness and Educating for Gross National happiness....

  10. Review of European regulatory and tariff experience with the sale of heat and electricity from combined heat and power plants

    International Nuclear Information System (INIS)

    Dyrelund, A.

    1991-12-01

    The Prince Edward Island Energy Corporation, Edmonton Power, Energy, Mines and Resources Canada and the Canadian Electrical Association commissioned a study to understand how electrical power and district heat from combined heat and power (CHP) plants is priced in Europe. Four northern European countries were investigated, Denmark, Germany, Sweden and Finland. These countries produce 45.8 TWh of power from combined heat and power plants, 7.1% of their annual consumption. In the case of Denmark, CHP accounts for 37.5% of its total power production. The energy situation in each country is reviewed using published statistics, and in particular the rapidly changing situation with regard to environmental and fuel taxes is examined. In order to obtain practical insights with regard to tariffs used by the various utilities, a series of generic examples were examined, supported by specific case studies. Technologies reviewed included: CHP from coal-fuelled extraction plant, CHP from coal-fuelled back pressure plant, waste heat from a municipal waste plant, and gas turbine with waste heat recovery. The benefits and risks associated with different tariff designs are discussed in detail including tariff formulae. This should enable interested parties to develop appropriate tariffs for combined heat and power plants in the context of current electrical utility policies. As a complement to the tariffs for combined heat and power plants, the design of district heating tariffs is also addressed. The typical concepts used in different countries are presented and discussed. 23 tabs

  11. Anaerobic Digestion and Combined Heat and Power Study

    Energy Technology Data Exchange (ETDEWEB)

    Frank J. Hartz

    2011-12-30

    One of the underlying objectives of this study is to recover the untapped energy in wastewater biomass. Some national statistics worth considering include: (1) 5% of the electrical energy demand in the US is used to treat municipal wastewater; (2) This carbon rich wastewater is an untapped energy resource; (3) Only 10% of wastewater treatment plants (>5mgd) recover energy; (4) Wastewater treatment plants have the potential to produce > 575 MW of energy nationwide; and (5) Wastewater treatment plants have the potential to capture an additional 175 MW of energy from waste Fats, Oils and Grease. The WSSC conducted this study to determine the feasibility of utilizing anaerobic digestion and combined heat and power (AD/CHP) and/or biosolids gasification and drying facilities to produce and utilize renewable digester biogas. Digester gas is considered a renewable energy source and can be used in place of fossil fuels to reduce greenhouse gas emissions. The project focus includes: (1) Converting wastewater Biomass to Electricity; (2) Using innovative technologies to Maximize Energy Recovery; and (3) Enhancing the Environment by reducing nutrient load to waterways (Chesapeake Bay), Sanitary Sewer Overflows (by reducing FOG in sewers) and Greenhouse Gas Emissions. The study consisted of these four tasks: (1) Technology screening and alternative shortlisting, answering the question 'what are the most viable and cost effective technical approaches by which to recover and reuse energy from biosolids while reducing disposal volume?'; (2) Energy recovery and disposal reduction potential verification, answering the question 'how much energy can be recovered from biosolids?'; (3) Economic environmental and community benefit analysis, answering the question 'what are the potential economic, environmental and community benefits/impacts of each approach?'; and (4) Recommend the best plan and develop a concept design.

  12. Computational heat transfer analysis and combined ANN–GA ...

    Indian Academy of Sciences (India)

    structures have significant effect on heat transfer characteristics and proposed correlations for the same. Siw et al ... studied the permissible number of fins for heat transfer enhancement and solved the energy equa- ..... The high temperature region is represented by red colour which is the base plate temperature and from ...

  13. Computational heat transfer analysis and combined ANN–GA ...

    Indian Academy of Sciences (India)

    2016-08-26

    Aug 26, 2016 ... In the devices like laptops, microprocessors, the electric circuits generate heat while performing work which necessitates the use of fins. In the present work, the heat transfer characteristics of hollow cylindrical pin fin array on a vertical rectangular base plate is studied using commercial CFD code ANSYS ...

  14. Computational heat transfer analysis and combined ANN–GA ...

    Indian Academy of Sciences (India)

    In the devices like laptops, microprocessors, the electric circuits generate heat while performing work which necessitates the use of fins. In the present work, the heat transfer characteristics of hollow cylindrical pin fin array on a vertical rectangular base plate is studied using commercial CFD code ANSYS FLUENT© .

  15. An investigation of heat recovery of submarine diesel engines for combined cooling, heating and power systems

    International Nuclear Information System (INIS)

    Daghigh, Roonak; Shafieian, Abdellah

    2016-01-01

    Highlights: • The power output of the cycle is about 53 kW in the mass flow rate of 0.6 kg/s. • The output cooling water temperature of evaporator is 3.64 °C. • The absorption chiller has a coefficient of performance equal to 0.94. - Abstract: High temperature and mass flow rate of the exhaust gases of submarine diesel engines provide an appropriate potential for their thermal recovery. The current study introduces a combined cooling, heating and power system for thermal recovery of submarine diesel engines. The cooling system is composed of a mixed effect absorption chiller with two high and low pressure generators. The exhaust of the diesel engine is used in the high pressure generator, and the low pressure generator was divided into two parts. The required heat for the first and second compartments is supplied by the cooling water of the engine and condensation of the vapor generated in the high pressure generator, respectively. The power generation system is a Rankine cycle with an organic working fluid, which is considered a normal thermal system to supply hot water. The whole system is encoded based on mass stability, condensation and energy equations. The obtained findings showed that the maximum heat recovery for the power cycle occurs in exhaust gas mass ratio of 0.23–0.29 and working fluid mass flow rate of 0.45–0.57 kg/s. Further, for each specific mass ratio of exhaust gas, only a certain range of working fluid mass flow rate is used. In the refrigerant mass flow rate of 0.6 kg/s and exhaust gas mass ratio of 0.27, the power output of the cycle is 53 kW, which can also be achieved by simultaneous increase of refrigerant mass flow rate and exhaust gas mass ratio in a certain range of higher powers. In the next section, the overall distribution diagram of output water temperature of the thermal system is obtained according to the exhaust gas mass ratio in various mass flow rates, which can increase the potential of designing and controlling the

  16. Measure Guideline: Combination Forced-Air Space and Tankless Domestic Hot Water Heating Systems

    Energy Technology Data Exchange (ETDEWEB)

    Rudd, A.

    2012-08-01

    This document describes design and application guidance for combination space and tankless domestic hot water heating systems (combination systems) used in residential buildings, based on field evaluation, testing, and industry meetings conducted by Building Science Corporation. As residential building enclosure improvements continue to drive heating loads down, using the same water heating equipment for both space heating and domestic water heating becomes attractive from an initial cost and space-saving perspective. This topic is applicable to single- and multi-family residential buildings, both new and retrofitted.

  17. Measure Guideline. Combination Forced-Air Space and Tankless Domestic Hot Water Heating Systems

    Energy Technology Data Exchange (ETDEWEB)

    Rudd, Armin [Building Science Corporation Industry Team (BSC), Somerville, MA (United States)

    2012-08-01

    This document describes design and application guidance for combination space and tankless domestic hot water heating systems (combination systems) used in residential buildings, based on field evaluation, testing, and industry meetings conducted by Building Science Corporation. As residential building enclosure improvements continue to drive heating loads down, using the same water heating equipment for both space heating and domestic water heating becomes attractive from an initial cost and space-saving perspective. This topic is applicable to single- and multi-family residential buildings, both new and retrofitted.

  18. Thermodynamic analysis of heat recovery steam generator in combined cycle power plant

    OpenAIRE

    Ravi Kumar Naradasu; Rama Krishna Konijeti; Sita Rama Raju Venkata Alluru

    2007-01-01

    Combined cycle power plants play an important role in the present energy sector. The main challenge in designing a combined cycle power plant is proper utilization of gas turbine exhaust heat in the steam cycle in order to achieve optimum steam turbine output. Most of the combined cycle developers focused on the gas turbine output and neglected the role of the heat recovery steam generator which strongly affects the overall performance of the combined cycle power plant. The present paper is a...

  19. Encouraging Combined Heat and Power in California Buildings

    Energy Technology Data Exchange (ETDEWEB)

    Stadler, Michael [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Groissbock, Markus [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Cardoso, Goncalo [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Muller, Andreas [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Lai, Judy [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States)

    2013-02-01

    Governor Brown’s research priorities include an additional 6.5 GW of combined heat and power (CHP) by 2030. As of 2009, roughly 0.25 GW of small natural gas and biogas fired CHP is documented by the Self-Generation Incentive Program (SGIP) database. The SGIP is set to expire, and the anticipated grid de-carbonization based on the development of 20 GW of renewable energy will influence the CHP adoption. Thus, an integrated optimization approach for this analysis was chosen that allows optimizing the adoption of distributed energy resources (DER) such as photovoltaics (PV), CHP, storage technologies, etc. in the California commercial sector from the building owners’ perspective. To solve this DER adoption problem the Distributed Energy Resources Customer Adoption Model (DER-CAM), developed by the Lawrence Berkeley National Laboratory and used extensively to address the problem of optimally investing and scheduling DER under multiple settings, has been used. The application of CHP at large industrial sites is well known, and much of its potential is already being realized. Conversely, commercial sector CHP, especially those above 50 to 100 kW peak electricity load, is widely overlooked. In order to analyze the role of DER in CO2 reduction, 147 representative sites in different climate zones were selected from the California Commercial End Use Survey (CEUS). About 8000 individual optimization runs, with different assumptions for the electric tariffs, natural gas costs, marginal grid CO2 emissions, and nitrogen oxide treatment costs, SGIP, fuel cell lifetime, fuel cell efficiency, PV installation costs, and payback periods for investments have been performed. The most optimistic CHP potential contribution in this sector in 2020 will be 2.7 GW. However, this result requires a SGIP in 2020, 46% average electric efficiency for fuel cells, a payback period for investments of 10 years, and a CO2 focused approach of the building owners. In

  20. Dry heat and radiation combination effects on Aspergillus flavus Link. infecting cocoa beans

    International Nuclear Information System (INIS)

    Amoako-Atta, B.; Meier, H.; Odamtten, G.T.

    1981-01-01

    The paper deals with the effect of heat and radiation combination treatments on the control of microbial spoilage of cocoa beans caused by toxigenic Aspergillus flavus Link. The heat and radiation sources were from dry air oven heat and 60 Co gammacell 220 irradiator, respectively. The radiation doses used were either 0, 50, 100, 150 or 200 krad, with combined heat temperatures of 30, 60 or 90 0 C. At each temperature level three different exposure time intervals of either 15 min, 30 min or 60 min respectively, were used. Two reversible sequential heat/radiation combination effects were evaluated. The first sequence involved cocoa beans inoculated with A. flavus spores exposed first to dry heat at pre-determined temperature heat exposure time, followed by radiation treatment, then retention of samples in a constant humidity environmental chamber set at 80% for daily observation up to forty days post-treatment. The second sequence involved exposure of the inoculated beans first to radiation, then to heat before retention under fixed RH for observation. From their results, the authors arrive at four conclusions: first, that there is a critical radiation/heat combination range (200, 150 and 100 krad/90 0 C for 15 min) that significantly decontaminates (less than 5% mouldiness) A. flavus infected cocoa beans even under high relative humidity (80% RH) environment; second, that a temperature level of 90 0 C combined with 200, 150 or 100 krad maximizes such effect but the heat exposure time is a major factor; third, that low heat temperature ranges of 30 or 60 0 C, combined with low radiation dosages of 150 krad or below, enhance the rate of A. flavus spoilage effects of cocoa beans; and, lastly, that the sequence of exposure of the inoculated cocoa beans to heat/radiation combination influenced the spore germination; exposure to heat before radiation would sensitize the spores (200 krad/90 0 C) but results in an increased radioresistance. (author)

  1. Dry Heat and Radiation Combination Effects on Aspergillus Flavus Link. Infecting Cocoa Beans

    International Nuclear Information System (INIS)

    Amoako-Atta, B.; Meier, H.; Odamtten, G.T.

    1981-01-01

    The paper deals with the effect of heat and radiation combination treatments on the control of microbial spoilage of cocoa beans caused by toxigenic Aspergillus flavus Link. The heat and radiation sources were from dry air oven heat and 60 Co gammaceli 220 irradiator, respectively. The radiation doses used were either 0, 50, 100, 150 or 200 krad, with combined heat temperatures of 30, 60 or 90°C. At each temperature level three different exposure time intervals of either 15 min, 30 min or 60 min respectively, were used. Two reversible sequential heat/radiation combination effects were evaluated.. The first sequence involved cocoa beans inoculated with A. flavus spores exposed first to dry heat at pre-determined temperature heat exposure time, followed by radiation treatment, then retention of samples in a constant humidity environmental chamber set at 80% for daily observation up to forty days post-treatment. The second sequence involved exposure of the inoculated beans first to radiation, then to heat before retention under fixed RH for observation. From their results, the authors arrive at four conclusions: first, that there is a critical radiation/heat combination range (200, 150 and 100 krad/90°C for 15 min) that significantly decontaminates (less than 5% mouldiness) A. flavus infected cocoa beans even under high relative humidity (80% RH) environment; second, that a temperature level of 90°C combined with 200, 150 or 100 krad maximizes such effect but the heat exposure time is a major factor; third, that low heat temperature ranges of 30 or 60°C, combined with low radiation dosages of 150 krad or below, enhance the rate of A. flavus spoilage effects of cocoa beans; and, lastly, that the sequence of exposure of the inoculated cocoa beans to heat/radiation combination influenced the spore germination; exposure to heat before radiation would sensitize the spores (200 krad/90°C) but results in an increased radioresistance. (author)

  2. Impairment of antitoxic antitetanus immunity under the combined effect of radiation and heat

    International Nuclear Information System (INIS)

    Kurochkina, O.I.; Budagov, R.S.

    1990-01-01

    In experiments with mice a delay was noted in the development of secondary immune response to revaccination with a tetanic anatoxin after the combined effect of radiation and heat; the maximum antibody formation occured at later times. The low level of antitoxins within the first 10 days after the combined effect of radiation and heat correlated with the low tetanus resistance of animals

  3. Effects of air velocity and clothing combination on heating efficiency of an electrically heated vest (EHV): a pilot study.

    Science.gov (United States)

    Wang, Faming; Gao, Chuansi; Holmér, Ingvar

    2010-09-01

    Cold endangers the heat balance of the human body. Protective clothing is the natural and most common equipment against cold stress. However, clothing for cold protection may be bulky and heavy, affecting human performance and increasing the work load. In such cases, a heated garment with built-in heating elements may be helpful. This pilot study presents a method based on a thermal manikin to investigate the effects of air velocity and clothing combination on the heating efficiency of an electrically heated vest (EHV). An infrared thermal camera was used to detect surface temperature distributions of the EHV on the front and back. Results show that the heating efficiency of the EHV decreases with increasing air velocity. Changes in EHV sequence in the three-layer clothing combination also significantly affect the heating efficiency: it increases with the increasing number of layers on top of the EHV. The highest mean temperature on the inner surface of the EHV was 40.2 degrees C, which indicates that it is safe for the wearers. For the EHV to heat the human body effectively, we suggest that it be worn as a middle layer. Finally, the EHV is especially suitable for occupational groups whose metabolic rate is below 1.9 Mets.

  4. Heat illness in athletes: the dangerous combination of heat, humidity and exercise.

    Science.gov (United States)

    Coris, Eric E; Ramirez, Arnold M; Van Durme, Daniel J

    2004-01-01

    In 1980, 1700 people died during a prolonged heat wave in a region under-prepared for heat illness prevention. Dramatically underreported, heat-related pathology contributes to significant morbidity as well as occasional mortality in athletic, elderly, paediatric and disabled populations. Among US high school athletes, heat illness is the third leading cause of death. Significant risk factors for heat illness include dehydration, hot and humid climate, obesity, low physical fitness, lack of acclimatisation, previous history of heat stroke, sleep deprivation, medications (especially diuretics or antidepressants), sweat gland dysfunction, and upper respiratory or gastrointestinal illness. Many of these risk factors can be addressed with education and awareness of patients at risk. Dehydration, with fluid loss occasionally as high as 6-10% of bodyweight, appears to be one of the most common risk factors for heat illness in patients exercising in the heat. Core body temperature has been shown to rise an additional 0.15-0.2 degrees C for every 1% of bodyweight lost to dehydration during exercise. Identifying athletes at risk, limiting environmental exposure, and monitoring closely for signs and symptoms are all important components of preventing heat illness. However, monitoring hydration status and early intervention may be the most important factors in preventing severe heat illness.

  5. Large heat storage tank for load management nd implementation of ambient heat. District heating networks based on combined heat and power; Grosswaermespeicher zum Lastmanagement und zur Einbindung von Umweltenergie. Auf KWK basierende Fernwaermenetze

    Energy Technology Data Exchange (ETDEWEB)

    Gross, Sebastian; Rhein, Martin; Ruehling, Karin [Technische Universitaet Dresden (Germany). Inst. fuer Energietechnik

    2013-06-15

    The district heating based on combined heat and power is a transitional technology on the way to the supply of Germany with renewable energy. In the next years, this transitional technology can only be maintained and expanded when marketability is given. Therefore an appropriate combination has to be found from investment measures. Together with new aspects in the management strategy, these investment measures should significantly improve the marketability. The investment measures also aims to enable a primary energetic, appropriate combination of natural gas-based combined heat and power, renewable energy sources (solar thermal energy, ambient heat) and heat pump technology.

  6. Better use of the potential offered by large-scale heat-pumps - Planning, applications, client's opinion; Potenziale von Gross-Waermepumpen besser nutzen. Konzeption, Anwendungen, Kundensicht

    Energy Technology Data Exchange (ETDEWEB)

    Ehrbar, M.; Rognon, F. (eds.)

    2006-07-01

    These proceedings published by the Swiss Federal Office of Energy (SFOE) include the contributions presented at the 13{sup th} Conference of the Research Programme on Ambient Heat, Combined Heat and Power Systems and Cold-generation that was held at the University of Applied Sciences in Burgdorf, Switzerland in 2006. At the conference, ten papers were presented that covered technical and political aspects of the use of large-scale heat-pumps for heating and cooling applications. As an introduction, Fabrice Rognon, head of the SFOE programme, took a look at the relevance of large heat-pumps in Swiss energy policy. Peter Hubacher discussed the advantages and disadvantages offered by centralised and decentralised heat-pump systems from the energy and economics points of view. Bernhard Eggen took a look at heat-source concepts for large heat-pumps while Rolf Loehrer discussed meeting temperature requirements when extracting heat. Patrice Anstett presented a paper on the measurement of the parameters of an air/water heat pump with CO{sub 2} as a working fluid used for hot water preparation. A paper on a combined heating and cooling system for a food warehouse complex in southern Switzerland was presented by Vinicio Curti. Beat Wellig described ways to avoid excessive power consumption in building air-conditioning systems using exergy analysis. Jean-Philippe Borel took a further look at heat and cold generation using heat-pumps that use geothermal probes as a thermal source. The use of large-scale heat-pump systems in contracting installations was examined by Georg Dubacher. Finally, reinsurance expert Primo Bianchi discussed if ecology and economy are inconsistent with each other. Two of these contributions, those of Peter Hubacher, who discussed the energy and economics of centralised and decentralised heat-pump systems and Jean-Philippe Borel, who examined heat and cold generation using geothermal probes as a thermal source, are also covered in two separately

  7. Comprehensive thermodynamic analysis of a renewable energy sourced hybrid heating system combined with latent heat storage

    International Nuclear Information System (INIS)

    Utlu, Zafer; Aydın, Devrim; Kıncay, Olcay

    2014-01-01

    Highlights: • An experimental thermal investigation of hybrid renewable heating system is presented. • Analyses were done by using real data obtained from a prototype structure. • Exergy efficiency of system components investigated during discharging period are close to each other as 32%. • The average input energy and exergy rates to the LHS were 0.770 and 0.027 kW. • Overall total energy and exergy efficiencies of LHS calculated as 72% and 28.4%. - Abstract: In this study an experimental thermal investigation of hybrid renewable heating system is presented. Latent heat storage stores energy, gained by solar collectors and supplies medium temperature heat to heat pump both day time also night time while solar energy is unavailable. In addition to this an accumulation tank exists in the system as sensible heat storage. It provides supply–demand balance with storing excess high temperature heat. Analyses were done according to thermodynamic’s first and second laws by using real data obtained from a prototype structure, built as part of a project. Results show that high percent of heat loses took place in heat pump with 1.83 kW where accumulator-wall heating cycle followed it with 0.42 kW. Contrarily highest break-down of exergy loses occur accumulator-wall heating cycle with 0.28 kW. Averagely 2.42 kW exergy destruction took place in whole system during the experiment. Solar collectors and heat pump are the promising components in terms of exergy destruction with 1.15 kW and 1.09 kW respectively. Exergy efficiency of system components, investigated during discharging period are in a close approximately of 32%. However, efficiency of solar collectors and charging of latent heat storage are 2.3% and 7% which are relatively low. Average overall total energy and exergy efficiencies of latent heat storage calculated as 72% and 28.4% respectively. Discharging energy efficiency of latent heat storage is the highest through all system components. Also heat

  8. Heat of fusion storage systems for combined solar systems in low energy buildings

    DEFF Research Database (Denmark)

    Schultz, Jørgen Munthe; Furbo, Simon

    2004-01-01

    Solar heating systems for combined domestic hot water and space heating has a large potential especially in low energy houses where it is possible to take full advantage of low temperature heating systems. If a building integrated heating system is used – e.g. floor heating - the supply temperature...... (and the the return temperature) would only be a few degrees above room temperature due to the very low heating demand and the large heat transfer surface area. One of the objectives in a newly started IEA Task 32 project is to investigate and develop improved thermal storages for combined solar...... systems through further improvement of water based storages and in parallel to investigate the potential of using storage designs with phase change materials, PCM. The advantage of phase change materials is that large amounts of energy can be stored without temperature increase when the material is going...

  9. Cadaver-specific CT scans visualized at the dissection table combined with virtual dissection tables improve learning performance in general gross anatomy

    Energy Technology Data Exchange (ETDEWEB)

    Paech, Daniel [German Cancer Research Center, Department of Radiology, Heidelberg (Germany); Heidelberg University, Institute of Anatomy and Cell Biology, Heidelberg (Germany); Giesel, Frederik L. [University Hospital Heidelberg, Department of Nuclear Medicine, Heidelberg (Germany); Unterhinninghofen, Roland [Institute of Anthropomatics, Karlsruhe Institute of Technology, Karlsruhe (Germany); Schlemmer, Heinz-Peter [German Cancer Research Center, Department of Radiology, Heidelberg (Germany); Kuner, Thomas; Doll, Sara [Heidelberg University, Institute of Anatomy and Cell Biology, Heidelberg (Germany)

    2017-05-15

    The purpose of this study was to quantify the benefit of the incorporation of radiologic anatomy (RA), in terms of student training in RA seminars, cadaver CT scans and life-size virtual dissection tables on the learning success in general anatomy. Three groups of a total of 238 students were compared in a multiple choice general anatomy exam during first-year gross anatomy: (1) a group (year 2015, n{sub 1} = 50) that received training in radiologic image interpretation (RA seminar) and additional access to cadaver CT scans (CT + seminar group); (2) a group (2011, n{sub 2} = 90) that was trained in the RA seminar only (RA seminar group); (3) a group (2011, n{sub 3} = 98) without any radiologic image interpretation training (conventional anatomy group). Furthermore, the students' perception of the new curriculum was assessed qualitatively through a survey. The average test score of the CT + seminar group (21.8 ± 5.0) was significantly higher when compared to both the RA seminar group (18.3 ± 5.0) and the conventional anatomy group (17.1 ± 4.7) (p < 0.001). The incorporation of cadaver CT scans and life-size virtual dissection tables significantly improved the performance of medical students in general gross anatomy. Medical imaging and virtual dissection should therefore be considered to be part of the standard curriculum of gross anatomy. circle Students provided with cadaver CT scans achieved 27 % higher scores in anatomy. (orig.)

  10. Thermal Efficiency of Power Module “Boiler with Solar Collectors as Additional Heat Source” For Combined Heat Supply System

    Directory of Open Access Journals (Sweden)

    Denysova A.E.

    2015-04-01

    Full Text Available The purpose of work is to increase the efficiency of the combined heat supply system with solar collectors as additional thermal generators. In order to optimize the parameters of combined heat supply system the mathematical modeling of thermal processes in multi module solar collectors as additional thermal generators for preheating of the water for boiler have been done. The method of calculation of multi-module solar collectors working with forced circulation for various configurations of hydraulic connection of solar collector modules as the new result of our work have been proposed. The results of numerical simulation of thermal efficiency of solar heat source for boiler of combined heat supply system with the account of design features of the circuit; regime parameters of thermal generators that allow establishing rational conditions of its functioning have been worked out. The conditions of functioning that provide required temperature of heat carrier incoming to boiler and value of flow rate at which the slippage of heat carrier is not possible for different hydraulic circuits of solar modules have been established.

  11. Performances of nuclear power plants for combined production of electricity and hot water for district heating

    International Nuclear Information System (INIS)

    Bronzen, S.

    The possibilities for using nuclear power plants for combined production of heat and power seem to be very good in the future. With the chosen 600 MWsub (e) BWR plant a heat output up to 1200 MW can be arranged. An alternative, consisting of steam extractions from the low-pressure turbine, offers a flexible solution for heat and power generation. With this alternative the combined plant can use components from normal condensing nuclear power plants. The flexible extraction design also offers a real possibility for using the combined plant in electric peak generation. However, urban siting requires long distance heat transmission and the pipe design for this transmission is a major problem when planning and optimizing the whole nuclear combined heat and power plant. (author)

  12. Combined Heat and Power Dispatch Considering Heat Storage of Both Buildings and Pipelines in District Heating System for Wind Power Integration

    Directory of Open Access Journals (Sweden)

    Ping Li

    2017-06-01

    Full Text Available The strong coupling between electric power and heat supply highly restricts the electric power generation range of combined heat and power (CHP units during heating seasons. This makes the system operational flexibility very low, which leads to heavy wind power curtailment, especially in the region with a high percentage of CHP units and abundant wind power energy such as northeastern China. The heat storage capacity of pipelines and buildings of the district heating system (DHS, which already exist in the urban infrastructures, can be exploited to realize the power and heat decoupling without any additional investment. We formulate a combined heat and power dispatch model considering both the pipelines’ dynamic thermal performance (PDTP and the buildings’ thermal inertia (BTI, abbreviated as the CPB-CHPD model, emphasizing the coordinating operation between the electric power and district heating systems to break the strong coupling without impacting end users’ heat supply quality. Simulation results demonstrate that the proposed CPB-CHPD model has much better synergic benefits than the model considering only PDTP or BTI on wind power integration and total operation cost savings.

  13. Combined forced and free convective heat transfer characteristics in narrow vertical rectangular channel heated from both sides

    International Nuclear Information System (INIS)

    Sudo, Yukio; Kaminaga, Masanori; Ikawa, Hiromasa

    1987-01-01

    Combined forced and free convective heat transfer characteristics were experimentally investigated for water flowing under about 1 atm in a narrow vertical rectangular (750 mm long, 50 mm wide and 18 mm in gap) channel heated from both sides. Experiments were carried out for both downward and upward forced convective flows for Reynolds number Re of 4 x 10 1 ∼ 5 x 10 5 and Grashof number Gr of 5 x 10 4 ∼ 4 x 10 11 , where the distance x from the inlet of the channel is adopted as the characteristic length in Re and Gr. As the results, the following were revealed : (1) Heat transfer coefficients for the combined convective flow region can be expressed in simple forms with a dimensionless parameter Gr/(Re 21/8 Pr 1/2 ) which is constituted by Gr, Re and Prandtl number Pr. (2) From the above-mentioned simple expressions it can be identified that the combined convective heat transfer is significant for the condition of 2.5 x 10 -4 21/8 Pr 2/1 ) -3 . (3) In the present experiment, little significant differences were observed in heat transfer characteristics between the combined convective flow region with upward forced convective flow and that with downward forced convective flow. (author)

  14. Combined Effect of Far Infrared Heating on the Quality of Vegetable Oil During Superheated Steam Treatment

    OpenAIRE

    雨坪, 知音; 羽倉, 義雄; 鈴木, 寛一

    2007-01-01

    Changes in the quality of soybean oil heated using superheated steam (SHS) combined with far infrared heating (FIH) were compared to those of oil heated using SHS only. Oil quality was measured with respect to acid value (AV), peroxide value (POV) and viscosity. For the SHS treatment, oil was heated at two temperatures (180°C and 230°C). For the combined treatment of SHS with FIH (SHS + FIH), oil temperature was 180°C and the surface temperature of the FIH ceramic heater was 230°C. Change...

  15. Gross, Prof. David J

    Indian Academy of Sciences (India)

    Fellow Profile. Elected: 2007 Honorary. Gross, Prof. David J. Date of birth: 1941. Address: Kavli Institute for Theoretical, Physics, University of California, Santa Barbara, CA 93106-4030, U.S.A.. Contact: Office: (+1-805) 893 7337. Residence: (+1-805) 963 8324. Fax: (+1-893) 893 2431. Email: gross@kitp.ucsb.edu. YouTube ...

  16. The Heat Transfer Coefficient of Recycled Concrete Bricks Combination with EPS Insulation Board Wall

    Directory of Open Access Journals (Sweden)

    Jianhua Li

    2015-01-01

    Full Text Available Four tectonic forms samples were conducted to test their heat transfer coefficients. By analyzing and comparing the test values and theoretical values of the heat transfer coefficient, a corrected-value calculation method for determining the heat transfer coefficient was proposed; the proposed method was proved to be reasonably correct. The results indicated that the recycled concrete brick wall heat transfer coefficient is higher than that of the clay brick wall, the heat transfer coefficient of recycled concrete brick wall could be effectively reduced when combined with the EPS insulation board, and the sandwich insulation type was better than that of external thermal insulation type.

  17. Technical assessment of electric heat boosters in low-temperature district heating based on combined heat and power analysis

    DEFF Research Database (Denmark)

    Cai, Hanmin; You, Shi; Wang, Jiawei

    2018-01-01

    This paper provides a technical assessment of electric heat boosters (EHBs) in low-energy districts. The analysis is based on a hypothetical district with 23 terraced single-family houses supplied by both a lowtemperature district heating (LTDH) network and a low-voltage network (LVN). Two case...... studies are provided to show the active role of EHBs in a smart energy system (SES). The first case compares annual heat and power flow analyses for LTDH at five supply temperature levels, focusing on their impacts. The results show that district heating network (DHN) losses can be reduced by 35......% if the supply temperature is reduced from 70 C to 50 C, but the LVN peak power will have to be increased by up to 2% using heat boosting. The second case further aggregates EHBs to provide a fuel shift (FS) service for the DHN. The results show that while LVN peak power was increased by up to 4.3%, the basic...

  18. Optimal Solutions for Load Sharing between Units of a Combined Heat and Power Plant

    Directory of Open Access Journals (Sweden)

    Shchinnikov P. A.

    2017-12-01

    Full Text Available The article presents the optimization method of load division between combined heat and power plant units. The method used the power unit division into functioning parts and the differential-exergy method. This method allowed presenting the unit as a structural diagram where exergetic subsystems are fuel supply, steam generator, turbine, generator and electrical equipment, water supply and regeneration, heat supply to the consumer. The differential-exergy method was based on a combination of exergy analysis and optimization method of economic efficiency criteria using uncertain Lagrange multipliers. The use of the exergy function of goal allowed avoiding the problem of division of fuel costs for each type of product that was important at optimization. The optimization criterion, its parameters and limitations were developed as well. These parameters can extend traditional technical and economic analysis of the combined heat and power plants operating mode, as they take into account thermodynamically rigorous division of fuel costs between heat and electric power at their complex production on the combined heat and power plants. The use of the differential-exergy method in optimizing the load distribution of the power units of the combined heat and power plants makes possible obtaining of fuel savings of 1.5 to 3%. It has been shown that if the parameters of power units deteriorate, the application of the method makes it possible to have the best performance of the power plant when it is compared with functioning of combined heat and power units at proportional loading.

  19. Enhancement of combined heat and mass transfer in a vertical-tube heat and mass exchanger

    International Nuclear Information System (INIS)

    Webb, R.L.; Perez-Blanco, H.

    1986-01-01

    This paper studies enhancement of heat and mass transfer between a countercurrent, gravity-drained water film and air flowing in a vertical tube. The enhancement technique employed is spaced, transverse wires placed in the air boundary layer, near the air--water interface. Heat transfer correlations for turbulent, single-phase heat transfer in pipes having wall-attached spaced ribs are used to select the preferred wire diameter, and to predict the gas phase heat and mass transfer coefficients. Tests were run with two different radial placements of the rib roughness: (1) at the free surface of the liquid film, and (2) the base of the roughness displaced 0.51 mm into the air flow. The authors hypothesize that the best heat/mass transfer and friction performance will be obtained with the roughness at the surface of the water film. Experiments conducted with both roughness placements show that the authors' hypothesis is correct. The measured heat/mass transfer enhancement agreed very closely with the predicted values. A unique feature of the enhancement concept is that it does not require surface wetting of the enhancement device to provide enhancement

  20. Thermodynamic Analysis of a Ship Power Plant Operating with Waste Heat Recovery through Combined Heat and Power Production

    Directory of Open Access Journals (Sweden)

    Mirko Grljušić

    2014-11-01

    Full Text Available The goal of this research is to study a cogeneration plant for combined heat & power (CHP production that utilises the low-temperature waste energy in the power plant of a Suezmax-size oil tanker for all heating and electricity requirements during navigation. After considering various configurations, a standard propulsion engine operating at maximum efficiency and a CHP Plant with R245fa fluid using a supercritical organic Rankine cycle (ORC is selected. All the ship heat requirements can be covered by energy of organic fluid after expansion in the turbine, except feeder-booster heating. Hence, an additional quantity of working fluid may be heated using an after Heat Recovery Steam Generator (HRSG directed to the feeder-booster module. An analysis of the obtained results shows that the steam turbine plant does not yield significant fuel savings. However, a CHP plant with R245fa fluid using supercritical ORC meets all of the demands for electrical energy and heat while burning only a small amount of additional fuel in HRSG at the main engine off-design operation.

  1. Technical Analysis of Combined Solar Water Heating Systems for Cold Climate Regions

    OpenAIRE

    Hossein Lotfizadeh; André McDonald; Amit Kumar

    2016-01-01

    Renewable energy resources, which can supplement space and water heating for residential buildings, can have a noticeable impact on natural gas consumption and air pollution. This study considers a technical analysis of a combined solar water heating system with evacuated tube solar collectors for different solar coverage, ranging from 20% to 100% of the total roof area of a typical residential building located in Edmonton, Alberta, Canada. The alternative heating systems were conventional (n...

  2. Robust Management of Combined Heat and Power Systems via Linear Decision Rules

    DEFF Research Database (Denmark)

    Zugno, Marco; Morales González, Juan Miguel; Madsen, Henrik

    2014-01-01

    The heat and power outputs of Combined Heat and Power (CHP) units are jointly constrained. Hence, the optimal management of systems including CHP units is a multicommodity optimization problem. Problems of this type are stochastic, owing to the uncertainty inherent both in the demand for heat and...... linear decision rules to guarantee both tractability and a correct representation of the dynamic aspects of the problem. Numerical results from an illustrative example confirm the value of the proposed approach....

  3. Control of food-borne molds by combination of heat and radiation

    International Nuclear Information System (INIS)

    Padwal-Desai, S.R.; Bongirwar, D.R.

    1979-01-01

    After enumerating the fungi responsible for food spoilage, work done on the factors influencing growth of fungi in stored foods is reviewed and the methods using heat, radiation or chemicals for control of food-borne molds are briefly surveyed. Work on combination process employing heat treatment and radiation treatment is reviewed in detail. The review covers the following aspects: (1) theory and engineering aspects of combination process of heat and radiation including modes of heat transfer, radiation physics, radiation sources, heat radiation effect and calculation of energy balance of the process, (2) biological effects of heat, radiation and heat-radiation combination treatments on mold growth with special reference to DNA and (3) application of the process for mold control in cereal products, nuts and raisins and fruits. Heat treatment and radiation treatment have been found to complement each other and when given in proper sequence show synergism. Design requirements of radiation sources and heat transfer equipment are also surveyed. (M.G.B.)

  4. Application of biogas for combined heat and power production in the rural region

    International Nuclear Information System (INIS)

    Kozak, T.; Majchrzycka, A.

    2009-01-01

    The paper discusses combined production of heat and power (CHP) from biogas in a small-scale power plant placed in the rural region. Based on power and heat demands of the rural region and biomass supply, the CHP system was selected. Keywords: biogas, cogeneration

  5. Analysis of combined heat and mass transfer of water-vapor in a ...

    African Journals Online (AJOL)

    Jn this paper, the combined heat and mass transfer of water-vapor into a cylindrical zeolite adsorber has been numerically simulated The twodimensional heat and mass transfer equations are numerically solved using gPROMS program - a general Process Modeling System [J] program, inserting the proper initial and ...

  6. Application of industrial wood residues for combined heat and power production

    International Nuclear Information System (INIS)

    Majchrzycka, A.

    2015-01-01

    The paper discusses combined production of heat and power (CHP) from industrial wood residues. The system will be powered by wood residues generated during manufacturing process of wooden floor panels. Based on power and heat demands of the plant and wood residues potential, the CHP system was selected. Preliminary analysis of biomass conversion in CHP system and environmental impact was performed.

  7. A Numerical Study of Combined Convective and Radiative Heat Transfer in a Rocket Engine Combustion Chamber

    National Research Council Canada - National Science Library

    Savur, Mehmet

    2002-01-01

    A numerical study was conducted to predict the combined convective and radiative heat transfer rates on the walls of a small aspect ratio cylinder representative of the scaled model of a rocket engine combustion chamber...

  8. The Role of Distributed Generation and Combined Heat and Power (CHP) Systems in Data Centers

    Science.gov (United States)

    This report reviews how distributed generation (DG) resources such as fuel cells, reciprocating engines, and gas turbines can offer powerful energy efficiency savings in data centers, particularly when configured in combined heat and power (CHP) mode.

  9. Waste-heat boiler application for the Vresova combined cycle plant

    Energy Technology Data Exchange (ETDEWEB)

    Vicek, Z. [Energoprojekt Praha, Prague (Czechoslovakia)

    1995-12-01

    This report describes a project proposal and implementation of two combined-cycle units of the Vresova Fuel Complex (PKV) with 2 x 200 MWe and heat supply. Participation of ENERGOPROJECT Praha a.s., in this project.

  10. Cost Price of Products in the System of Heat, Refrigeration and Electric Energy Production Combined at Thermal Power Plant

    OpenAIRE

    Tubolev, Aleksandr Anatolievich; Romashova, Olga Yurievich; Belyaev, Leonid Aleksandrovich

    2016-01-01

    Nowadays combination of electric, heat and refrigerating energy production (trigeneration) is one of the modern technological solutions for energy efficiency increase and ecological problem solution [1]. Two types of refrigerating machines can be used for both energy and heat production combined: compression aggregates consuming electric energy and absorption aggregates using hot water heat, vapor or other heat conductors.

  11. Development of shelf stable, processed, low acid food products using heat-irradiation combination treatments

    International Nuclear Information System (INIS)

    Minnaar, A.

    1998-01-01

    The amount of ionizing irradiation needed to sterilize low acid vegetable and starch products (with and without sauces) commercially impairs their sensorial and nutritive qualities, and use of thermal processes for the same purpose may also have an adverse effect on the product quality. A systematic approach to the establishment of optimized combination parameters was developed for heat-irradiation processing to produce high quality, shelf stable, low acid food products. The effects of selected heat, heat-irradiation combination and irradiation treatments on the quality of shelf stable mushrooms in brine and rice, stored at ambient temperature, were studied. From a quality viewpoint, use of heat-irradiation combination treatments favouring low irradiation dose levels offered a feasible alternative to thermally processed or radappertized mushrooms in brine. However, shelf stable rice produced by heat-irradiation combination treatments offered a feasible alternative only to radappertized rice from the standpoint of quality. The technical requirements for the heat and irradiation processing of a long grain rice cultivar from the United States of America oppose each other directly, thereby reducing the feasibility of using heat-irradiation combination processing to produce shelf stable rice. The stability of starch thickened white sauces was found to be affected severely during high dose irradiation and subsequent storage at ambient temperature. However, use of pea protein isolate as a thickener in white sauces was found to have the potential to maintain the viscosity of sauces for irradiated meat and sauce products throughout processing and storage. (author)

  12. Combined heat and power production through biomass gasification with 'Heatpipe-Reformer'

    International Nuclear Information System (INIS)

    Iliev, I.; Kamburova, V.; Terziev, A.

    2013-01-01

    The current report aims is to analyze the system for combined heat and power production through biomass gasification with “heatpipe-reformer” system. Special attention is paid on the process of synthetic gas production in the Reformer, its cleaning and further burning in the co-generation unit. A financial analysis is made regarding the investments and profits generated by the combined heat and power production. (authors)

  13. Calculation of gross energy in pet foods: new data on heat combustion and fibre analysis in a selection of foods for dogs and cats.

    Science.gov (United States)

    Kienzle, E; Schrag, I; Butterwick, R; Opitz, B

    2001-06-01

    Seven pectin samples, six galactomannan sources, five carrageen samples, four alginate samples, one sample of gum traganth, agar agar and gum arabicum, two xanthan samples, two inulin samples and a galacto oligosaccharide, 22 cellulose samples, six lignin samples, four starch samples, nine protein samples, six isolated fats, three meat samples, two lung samples, two samples of skimmed milk powder, 12 prepared complete dry dog foods, 21 moist dog foods, nine dry and 25 moist cat foods and 10 faecal samples were analysed for heat combustion (adiabatic bomb calorimetry), crude nutrients, acid detergent fibre (ADF), and acid detergent lignin (ADL). Some of the non-starch polysaccharides which gave low levels of crude fibre and ADF were also analysed for total, insoluble and soluble fibre. The heat combustion of cellulose ranged between 17.0 and 17.5 kJ/g organic matter (OM). The variation was somewhat larger for other non-starch polysaccharides (pectin, galactomannan sources, carageen, alginate, gums, xanthan, inulin) where heat combustion ranged between 14.0 and 18.2 kJ/g OM. The heat combustion of lignin averaged 25.5 kJ/g OM with considerable variation (17.0-29.2 kJ/g OM). Starch had a narrow range (17.2-17.3 kJ/g OM). Heat combustion of protein samples varied between 22.0 and 24.6 kJ/g, and of fat samples varied between 38.0 and 39.6 kJ/g OM. When cellulose was analysed for crude fibre only between 62 and 85% OM was detected. ADF analyses of cellulose ranged between 75 and 93% OM. The crude fibre content of all other non-starch polysaccharides did not exceed 13% OM, with the exception of pectins (ADF 0.7-37% OM) and alginates (ADF 39-66% OM), the ADF content was also below 13% in these samples. In contrast the total fibre content was above 80% OM in all non-starch noncellulose polysaccharides and the percentage of soluble fibre was high (25-93% OM). Unprocessed lignin gave high readings for crude fibre (39-61% OM) and ADF (96-99% OM), while processed lignin had low

  14. Gross Sales Tax Collections

    Data.gov (United States)

    City of Jackson, Mississippi — This data is captured directly from the MS Department of Revenue and specific to the City of Jackson. It is compiled from Gross Sales Tax reported by taxpayers each...

  15. Loovkirjutamist õpetab Philip Gross

    Index Scriptorium Estoniae

    2011-01-01

    T.S. Elioti luulepreemia laureaat Philip Gross on Tallinna Ülikooli talvekooli rahvusvahelise kursuse "Poetry: A Conversation between Words and Silence" läbiviija. Oma seminarides keskendub ta lisaks loovkirjutamisele ka loova lugemise vajadusele

  16. Combined installation of electric and heat supply for climatic conditions of Iraq

    Science.gov (United States)

    Kaisi, Osama Al; Sidenkov, D. V.

    2017-11-01

    Electricity, heating and cooling are the three main components that make up the energy consumption base in residential, commercial and public buildings around the world. Demand for energy and fuel costs are constantly growing. Combined cooling, heating and power generation or trigeneration can be a promising solution to such a problem, providing an efficient, reliable, flexible, competitive and less harmful alternative to existing heat and cold supply systems. In this paper, scheme of the tri-generation plant on non-aqueous working substances is considered as an installation of a locally centralized electro-heat and cold supply of a typical residential house in a hot climate. The scheme of the combined installation of electro-heat (cold) supply consisted of the vapor power plant and heat pump system on low-boiling working substance for local consumers under the climatic conditions of Iraq is presented. The possibility of using different working substances in the thermodynamic cycles of these units, which will provide better efficiency of such tri-generation systems is shown. The calculations of steam turbine cycles and heat pump part on the selected working substances are conducted. It is proposed to use heat exchangers of plate type as the main exchangers in the combined processing. The developed method of thermal-hydraulic calculation of heat exchangers implemented in MathCad, which allows to evaluate the efficiency of plants of this type using the ε - NTU method. For the selected working substances of the steam part the optimal temperature of heat supply to the steam generator is determined. The results of thermodynamic and technical-economic analysis of the application of various working substances in the “organic” Rankine cycle of the steam turbine unit and the heat pump system of the heat and cold supply system are presented.

  17. Calculation of Efficiencies of a Ship Power Plant Operating with Waste Heat Recovery through Combined Heat and Power Production

    Directory of Open Access Journals (Sweden)

    Mirko Grljušić

    2015-05-01

    Full Text Available The aim of this research was to investigate the possibility of a combined heat & power (CHP plant, using the waste heat from a Suezmax-size oil tanker’s main engine, to meet all heating and electricity requirements during navigation. After considering various configurations, a standard propulsion engine operating at maximum efficiency, combined with a supercritical Organic Rankine cycle (ORC system, was selected to supply the auxiliary power, using R245fa or R123 as the working fluid. The system analysis showed that such a plant can meet all heat and electrical power requirements at full load, with the need to burn only a small amount of supplementary fuel in a heat recovery steam generator (HRSG when the main engine operates at part load. Therefore, it is possible to increase the overall thermal efficiency of the ship’s power plant by more than 5% when the main engine operates at 65% or more of its specified maximum continuous rating (SMCR.

  18. HOME ENERGY SUPPLY-DEMAND ANALYSIS FOR COMBINED SYSTEM OF SOLAR HEAT COLLECTOR AND HEAT PUMP WATER HEATER

    Science.gov (United States)

    Ikegami, Takashi; Kataoka, Kazuto; Iwafune, Yumiko; Ogimoto, Kazuhiko

    In order to evaluate effectiveness of a combined system of solar heat collecctor (SHC) and heat pump water heater (HPWH), optimum operation scheduling moldel of domestic electric appliances using the mixed integer linear programming was enhanced. Applying this model with one house data in Tokyo, it was found that the combined system of the SHC and the HPWH has the enough energy-saving and CO2 emission reduction potential under the existing electricity late and the operation method of the HPWH. Furthermore, the calculation results under the future system show that the combined system of the SHC and the HPWH has also the reduction effect of reverse power flow from residential photovoltaic system.

  19. Combined solar heat and power system with a latent heat storage - system simulations for an economic assessment

    Science.gov (United States)

    Zipf, Verena; Neuhäuser, Anton

    2016-05-01

    Decentralized solar combined heat and power (CHP) systems can be economically feasible, especially when they have a thermal storage. In such systems, heat provided by solar thermal collectors is used to generate electricity and useful heat for e.g. industrial processes. For the supply of energy in times without solar irradiation, a thermal storage can be integrated. In this work, the performance of a solar CHP system using an active latent heat storage with a screw heat exchanger is investigated. Annual yield calculations are conducted in order to calculate annual energy gains and, based on them; economic assumptions are used to calculated economic numbers in order to assess the system performance. The energy savings of a solar system, compared to a system with a fossil fuel supply, are calculated. Then the net present value and the dynamic payback are calculated with these savings, the initial investment costs and the operational costs. By interpretation and comparison of these economic numbers, an optimum system design in terms of solar field size and storage size was determined. It has been shown that the utilization of such systems can be economical in remote areas without gas and grid connection. Optimal storage design parameters in terms of the temperature differences in the heat exchanger and the storage capacity have been determined which can further increase the net present value of such system.

  20. Stochastic Programming for Fuel Supply Planning of Combined Heat and Power Plants

    DEFF Research Database (Denmark)

    Guericke, Daniela; Blanco, Ignacio; Morales González, Juan Miguel

    The consumption of biomass to produce power and heat has increased due to the carbon neutral policies. Combined heat and power (CHP) plants often combine biomass with other fuels, e.g., natural gas. The negotiation process for supply contracts involves many uncertainties due to the long planning...... horizon. The demand for biomass is uncertain, and heat demand and electricity prices vary during the planning period. We propose a method using stochastic optimization to support the biomass and natural gas supply planning for CHP plants including short-term decisions for optimal market participation....

  1. Combined Influence of Strain and Heat Loss on Turbulent Premixed Flame Stabilization

    KAUST Repository

    Tay-Wo-Chong, Luis

    2015-11-16

    The present paper argues that the prediction of turbulent premixed flames under non-adiabatic conditions can be improved by considering the combined effects of strain and heat loss on reaction rates. The effect of strain in the presence of heat loss on the consumption speed of laminar premixed flames was quantified by calculations of asymmetric counterflow configurations (“fresh-to-burnt”) with detailed chemistry. Heat losses were introduced by setting the temperature of the incoming stream of products on the “burnt” side to values below those corresponding to adiabatic conditions. The consumption speed decreased in a roughly exponential manner with increasing strain rate, and this tendency became more pronounced in the presence of heat losses. An empirical relation in terms of Markstein number, Karlovitz Number and a non-dimensional heat loss parameter was proposed for the combined influence of strain and heat losses on the consumption speed. Combining this empirical relation with a presumed probability density function for strain in turbulent flows, an attenuation factor that accounts for the effect of strain and heat loss on the reaction rate in turbulent flows was deduced and implemented into a turbulent combustion model. URANS simulations of a premixed swirl burner were carried out and validated against flow field and OH chemiluminescence measurements. Introducing the effects of strain and heat loss into the combustion model, the flame topology observed experimentally was correctly reproduced, with good agreement between experiment and simulation for flow field and flame length.

  2. Economical Efficiency of Combined Cooling Heating and Power Systems Based on an Enthalpy Method

    Directory of Open Access Journals (Sweden)

    Yan Xu

    2017-11-01

    Full Text Available As the living standards of Chinese people have been improving, the energy demand for cooling and heating, mainly in the form of electricity, has also expanded. Since an integrated cooling, heating and power supply system (CCHP will serve this demand better, the government is now attaching more importance to the application of CCHP energy systems. Based on the characteristics of the combined cooling heating and power supply system, and the method of levelized cost of energy, two calculation methods for the evaluation of the economical efficiency of the system are employed when the energy production in the system is dealt with from the perspective of exergy. According to the first method, fuel costs account for about 75% of the total cost. In the second method, the profits from heating and cooling are converted to fuel costs, resulting in a significant reduction of fuel costs, accounting for 60% of the total cost. Then the heating and cooling parameters of gas turbine exhaust, heat recovery boiler, lithium-bromide heat-cooler and commercial tariff of provincial capitals were set as benchmark based on geographic differences among provinces, and the economical efficiency of combined cooling heating and power systems in each province were evaluated. The results shows that the combined cooling heating and power system is economical in the developed areas of central and eastern China, especially in Hubei and Zhejiang provinces, while in other regions it is not. The sensitivity analysis was also made on related influencing factors of fuel cost, demand intensity in heating and cooling energy, and bank loans ratio. The analysis shows that the levelized cost of energy of combined cooling heating and power systems is very sensitive to exergy consumption and fuel costs. When the consumption of heating and cooling energy increases, the unit cost decreases by 0.1 yuan/kWh, and when the on-grid power ratio decreases by 20%, the cost may increase by 0.1 yuan

  3. Combined forced and natural convective heat transfer from a vertical circular cylinder

    International Nuclear Information System (INIS)

    Kashiwagi, Eisuke; Okui, Hiroaki; Okuyama, Kunito; Iida, Yoshihiro

    2003-01-01

    An experimental study is conducted to investigate the characteristics of the combined forced and natural convection heat transfer on a vertical circular cylinder placed in a cross flow. Local heat transfer coefficients are measured precisely in the Reynolds number range from 760 to 3300 and the range of the modified Rayleigh number from 5.0 x 10 9 to 4.0 x 10 14 . The local heat transfer coefficients under combined convection increase both on the front and rear sides of the cylinder with an increase in heat flux. The reason is that the flow around the cylinder is sped by buoyancy force. The average Nusselt numbers for the combined convection become higher than those estimated for both of forced and natural convection. (author)

  4. Combined forced and natural convection heat transfer for upward flow in a uniformly heated vertical pipe

    International Nuclear Information System (INIS)

    Tanaka, Hiroaki; Hatano, Shunichi; Maruyama, Shigeo.

    1986-01-01

    For predicting the fully developed upward flow in a uniformly heated vertical pipe by taking account of the buoyancy force, the k-ε models of turbulence for low Reynolds number flows were adopted. The regime map for forced, mixed and natural convections as well as for laminar and turbulent flows was plotted from the numerical calculations. At the same time, an experiment was carried out at Reynolds numbers of 3000 and 5000 with the Grashof number varied over a wide range by using pressurized nitrogen gas as a test fluid. In agreement with the prediction, buoyancy-induced impairment of heat transfer was measured right in the mixed convection region. Further, from hot-wire measurement, complete laminarization was demonstrated in the mixed convection region at a Reynolds number of 3000. (author)

  5. Large Combined Heat and Power Plants for Sustainable Energy System

    DEFF Research Database (Denmark)

    Lund, Rasmus Søgaard; Mathiesen, Brian Vad

    in Denmark; conversion of pulverised fuel plants from coal to wood pellets and a circulating fluidised bed (CFB) plant for wood chips. From scientific research projects another solution is suggested as the most feasible; the combined cycle gas turbine (CCGT) plant. In this study a four scenarios...... are constructed to analyse how the different alternatives influences the energy system. The scenarios are analysed in the energy systems modelling tool EnergyPLAN both from a technical energy systems perspective and from a market economic analysis with focus on the electricity exchange potential of the scenarios....... The scenarios are assessed on their total socioeconomic costs and the biomass consumption. The CCGT CHP plant is concluded to be the most feasible of the assessed types considering both a technical analysis and a market economic analysis with electricity exchange. It is also concluded that the current economic...

  6. Opportunities for Combined Heat and Power in Data Centers

    Energy Technology Data Exchange (ETDEWEB)

    Darrow, Ken [ICF International; Hedman, Bruce [ICF International

    2009-03-01

    types of facilities involved, and the geographic distribution. (2) Data Center Energy Use Trends--a discussion of energy use and expected energy growth and the typical energy consumption and uses in data centers. (3) CHP Applicability--Potential configurations, CHP case studies, applicable equipment, heat recovery opportunities (cooling), cost and performance benchmarks, and power reliability benefits (4) CHP Drivers and Hurdles--evaluation of user benefits, social benefits, market structural issues and attitudes toward CHP, and regulatory hurdles. (5) CHP Paths to Market--Discussion of technical needs, education, strategic partnerships needed to promote CHP in the IT community.

  7. Wood chip drying in connection with combined heat and power or solar energy in Finland

    Directory of Open Access Journals (Sweden)

    Rinne Samuli

    2014-01-01

    Full Text Available 20% of the Finnish district heating (DH power plant fuels are wood-based and the share is increasing. The wood fuel demand probably exceeds the potential supply in the future. The wood fuel drying with waste heat is one profitable opportunity to gain more wood fuel. If the drying energy can be produced with lower primary energy use than combusting the fuel directly, the drying potentially improves the system efficiency. In this study, the drying feasibility in the connection of a combined heat and power (CHP system, possibly with solar collectors, is calculated. The wood fuel heating can be increased profitably by 6%, using the heat from CHP for drying only when the marginal cost of the heat is low enough, i.e. the electricity price is high enough and there is free capacity after the DH demand. Although the drying is profitable, a larger heat storage can also increase the annual result similarly. The best investment choice depends on the plant properties. Here the optimal system enables 20% DH production cost savings. Solar heat may be profitable, when the solar heat has a 2–3% share of the annual heat demand. However, the dryer or larger storage tank are more profitable investments.

  8. Performance analysis on a new multi-effect distillation combined with an open absorption heat transformer driven by waste heat

    International Nuclear Information System (INIS)

    Zhang, Xiaodong; Hu, Dapeng; Li, Zhiyi

    2014-01-01

    In this paper, a new water distillation system, which consists of either a single- or multi-effect distiller combined with an open absorption heat transformer (OAHT), has been proposed. The new integrated system can be used for distilling waste water with high amounts of SiO 2 from heavy oil production, and the resultant distilled water can be supplied to steam boilers to produce high quality steam which in turn is injected into oil reservoirs to assist with heavy oil recovery. The thermodynamic cycle performances for these new integrated distillation systems were simulated based on the thermodynamic properties of the aqueous solution of LiBr as well as the mass and energy balance of the system. The results indicate that combined with OAHT, the waste heat at 70 °C can be elevated to 125 °C and thereby produce steam at 120 °C in the absorber, which is able to drive a four-effect distiller to produce distilled water. For a single-effect and four-effect distiller, the coefficients of performance (COP) are approximately 1.02 while the performance ratios are 2.19 and 5.72, respectively. Therefore, the four-effect distillation system combined with an OAHT is more thermally effective and is an ideal option to process the waste water in oilfields. -- Highlights: • A new absorption vapor compression distillation was proposed in present research. • An open absorption heat transformer has a coupled thermally evaporator and absorber. • Distillation of waste water with high content of SiO 2 from heavy oil production. • The waste heat of 70 °C can be elevated up to 125 °C and generate steam of 120 °C. • The waste heat is able to drive four-effect distillation to produce distilled water

  9. The Gross-Llewellyn Smith sum rule

    International Nuclear Information System (INIS)

    Scott, W.G.

    1981-01-01

    We present the most recent data on the Gross-Llewellyn Smith sum rule obtained from the combined BEBC Narrow Band Neon and GGM-PS Freon neutrino/antineutrino experiments. The data for the Gross-Llewellyn Smith sum rule as a function of q 2 suggest a smaller value for the QCD coupling constant parameter Λ than is obtained from the analysis of the higher moments. (author)

  10. Biomass Supply Planning for Combined Heat and Power Plants using Stochastic Programming

    DEFF Research Database (Denmark)

    Guericke, Daniela; Blanco, Ignacio; Morales González, Juan Miguel

    During the last years, the consumption of biomass to produce power and heat has increased due to the new carbon neutral policies. Nowadays, many district heating systems operate their combined heat and power (CHP) plants using different types of biomass instead of fossil fuel, especially to produ...... profitability and feasibility. The risk of major deficits in biomass supply is reduced by including appropriate risk measures to the models. We present numerical results and an economic analysis based on a realistic test case....... heat. Since biomass is transported from the supplier to the consumption sites and the contracts with the suppliers are negotiated months in advance, the negotiation process involves many uncertainties from the energy producer’s side. The demand for biomass is uncertain at the time of negotiation......, and heat demand and electricity prices vary drastically during the planning period. Furthermore, the optimal operation of combined heat and power plants has to consider the existing synergies between the power and heating systems while always fulfilling the heat demand of the system. We propose a solution...

  11. Efficiency Growth of Combined-cycle Cogeneration Plant with the Heat Supply System

    Directory of Open Access Journals (Sweden)

    Denysova Alla

    2015-08-01

    Full Text Available Energy efficiency of modern technologies of the combined production of heat and electricity and ways of energy saving on base of recycling secondary energy sources has been estimated. It is shown that the most effective for cogeneration are combined-cycle plants. The rational scheme of interaction of combined-cycle cogeneration plant with heat supply system has been offered. Theoretical bases of interaction of main installation with a contour of heat and hot water supply system has been developed. Numerical modeling of temperature parameters and the analysis of results of numerical modeling has been executed. The technology of increase of energy efficiency of installations on base of recycling heat is offered. Increase of effectiveness of system is achieved due to full use of heat and reduction of losses to environment. It is established, that the rational scheme of interaction of combined-cycle cogeneration plant with heat supply system allows increasing energy efficiency on 2 % that corresponds to economy of fuel 3 %.

  12. Exergy analysis of a combined heat and power plant with integrated lignocellulosic ethanol production

    DEFF Research Database (Denmark)

    Lythcke-Jørgensen, Christoffer Ernst; Haglind, Fredrik; Clausen, Lasse Røngaard

    2013-01-01

    Integrating second generation bioethanol production in combined heat and power units is expected to increase system energy efficiencies while producing sustainable fuel for the transportation sector at a competitive price. By applying exergy analysis, this study assessed the efficiency of an inte......Integrating second generation bioethanol production in combined heat and power units is expected to increase system energy efficiencies while producing sustainable fuel for the transportation sector at a competitive price. By applying exergy analysis, this study assessed the efficiency...... of an integrated system in which steam extracted from an existing combined heat and power unit is used for covering the heating demand of a lignocellulosic ethanol production facility. The integration solution was designed and optimized using already existing steam extraction points in the combined heat and power...... and losses in the system was in the range of 0.46-0.87 depending on the system operation. This study suggests that a well-designed heat integration network can increase the exergy efficiency of the integrated system markedly....

  13. Exergy, Economic and Environmental Analysis for Simple and Combined Heat and Power IC Engines

    Directory of Open Access Journals (Sweden)

    Mehdi Aliehyaei

    2015-04-01

    Full Text Available This study reports the results of exergy, economic and environmental analyses of simple and combined heat and power internal combustion engines. Values of entropy production, second law efficiency are calculated, and an objective function, including initial, operation, maintenance and fuel costs, as well as the external costs of environmental pollutants, such as CO2, CO and NOx, are presented for the flue gas of the internal combustion engine. The results show that entropy generation in the combined heat and power mode is 30% lower than that in the simple internal combustion engine. Also, by excessively increasing the air ratio, the system entropy generation decreases in both cases of simple and combined heat and power IC engines. The greatest portion of entropy generation is related to the combined heat and power internal combustion engine. The gas heat exchanger generates more entropy than the jacket heat exchanger. Lower values of electricity cost and external costs of air pollution are provided by higher values of molar air to fuel ratio. The environmental aspects depend on location of the system and time of engine operation.

  14. Exergy costing for energy saving in combined heating and cooling applications

    DEFF Research Database (Denmark)

    Nguyen, Chan; Veje, Christian T.; Willatzen, Morten

    2014-01-01

    . In the first method, referred to as energy costing, a conventional thermoeconomic analysis is used. Here the ammonia heat pump is subject to a thermodynamic analysis with mass and energy balance equations. In the second method referred to as exergy costing, an exergy based economic analysis is used, where...... exergy balance equations are used in conjunction with mass and energy balance equations. In both costing methods the thermodynamic analysis is followed by an economic analysis which includes investment and operating costs. For both methods the unit costs of heating and cooling are found and compared......The aim of this study is to provide a price model that motivates energy saving for a combined district heating and cooling system. A novel analysis using two thermoeconomic methods for apportioning the costs to heating and cooling provided simultaneously by an ammonia heat pump is demonstrated...

  15. Combined generation of electric and heating energy in future development of Yugoslav energy sector until 2000

    International Nuclear Information System (INIS)

    Djajic, Nenad; Zivanovic, Vladimir

    2000-01-01

    Development of the district heating system in the FR Yugoslavia, beside the combined generation of electric and heating energy presents a necessity for energy, economic and ecological reasons. Although the structure of energy reserves is rather unfavourable considering that the lignite is being predominantly used, available reserves of energy raw material are able to ensure the long-term development of Yugoslav energy sector, and to offer real possibilities for considerable substitution of foreign good quality fuels, especially in district heating systems. Their further development will depend, among other things: on the implementation of new technological solutions for the exploitation of local energy resources; need of reconstruction, revitalisation and transformation of old condensing thermal power plants into the cogeneration plants; installation of remote controlled transmission of heating energy as well as on development of heating plants and smaller co-generation plants based on local energy resources. (Authors)

  16. Combining several thermal indices to generate a unique heat comfort assessment methodology

    OpenAIRE

    Wissam EL Hachem; Joseph Khoury; Ramy Harik

    2015-01-01

    Purpose: The proposed methodology hopes to provide a systematic multi-disciplinary approach to assess the thermal environment while minimizing unneeded efforts. Design/methodology/approach: Different factors affect the perception of the human thermal experience: metabolic rate (biology), surrounding temperatures (heat balance and environmental factors) and cognitive treatment (physiology).This paper proposes a combination of different multidisciplinary variables to generate a unique heat comf...

  17. A Better Steam Engine: Designing a Distributed Concentrating Solar Combined Heat and Power System

    OpenAIRE

    Norwood, Zachary Mills

    2011-01-01

    The result of several years of analysis of Distributed Concentrating Solar Combined Heat and Power (DCS-CHP) systems is a design that is predicted to convert sunlight to heat at 8-10% solar-electric efficiency while simultaneously capturing ~60% of that initial sunlight as usable heat (at 100ºC). In contrast to similarly sized photovoltaic systems in the U.S. that cost ~$7.90/Watt of generator rated peak electrical output, in mass production the proposed collector and generator system sized a...

  18. Evaluation of alternatives of exothermic methanization cycle for combined electricity and heat generation

    International Nuclear Information System (INIS)

    Balajka, J.; Princova, H.

    1987-01-01

    The possibilities are discussed of using the ADAM-EVA system for remote heat supply from nuclear heat sources to district heating systems. Attention is devoted to the use of the exothermal methanization process (ADAM station) for the combined power and heat production, this making use of the existing hot water power distribution network. The basic parameter for the evaluation of the over-all efficiency of the combined power and heat production is the maximum methanization cycle temperature which depends on the life of the methanization catalyst. Upon temperature drop below 550 degC, the conversion process can only be secured by means of two-stage methanization, which leads to a simplification of the cycle and a reduction in investment cost. At a temperature lower than 500 degC, combined power and heat production cannot be implemented. On the contrary, a considerable amount of electric power supplied from outside the system would be needed for compression work. (Z.M.)

  19. Thermodynamic performance analysis and optimization of a solar-assisted combined cooling, heating and power system

    International Nuclear Information System (INIS)

    Wang, Jiangjiang; Lu, Yanchao; Yang, Ying; Mao, Tianzhi

    2016-01-01

    This study aims to present a thermodynamic performance analysis and to optimize the configurations of a hybrid combined cooling, heating and power (CCHP) system incorporating solar energy and natural gas. A basic natural gas CCHP system containing a power generation unit, a heat recovery system, an absorption cooling system and a storage tank is integrated with solar photovoltaic (PV) panels and/or a heat collector. Based on thermodynamic modeling, the thermodynamic performance, including energy and exergy efficiencies, under variable work conditions, such as electric load factor, solar irradiance and installation ratio, of the solar PV panels and heat collector is investigated and analyzed. The results of the energy supply side analysis indicate that the integration of solar PV into the CCHP system more efficiently improves the exergy efficiency, whereas the integration of a solar heat collector improves the energy efficiency. To match the building loads, the optimization method combined with the operation strategy is employed to optimize the system configurations to maximize the integrated benefits of energy and economic costs. The optimization results of demand–supply matching demonstrate that the integration of a solar heat collector achieves a better integrated performance than the solar PV integration in the specific case study. - Highlights: • Design a CCHP system integrated with solar PV and heat collector. • Present the energy and exergy analyses under variable work conditions. • Propose an optimization method of CCHP system for demand-supply matching.

  20. Combining high-resolution gross domestic product data with home and personal care product market research data to generate a subnational emission inventory for Asia.

    Science.gov (United States)

    Hodges, Juliet Elizabeth Natasha; Vamshi, Raghu; Holmes, Christopher; Rowson, Matthew; Miah, Taqmina; Price, Oliver Richard

    2014-04-01

    Environmental risk assessment of chemicals is reliant on good estimates of product usage information and robust exposure models. Over the past 20 to 30 years, much progress has been made with the development of exposure models that simulate the transport and distribution of chemicals in the environment. However, little progress has been made in our ability to estimate chemical emissions of home and personal care (HPC) products. In this project, we have developed an approach to estimate subnational emission inventory of chemical ingredients used in HPC products for 12 Asian countries including Bangladesh, Cambodia, China, India, Indonesia, Laos, Malaysia, Pakistan, Philippines, Sri Lanka, Thailand, and Vietnam (Asia-12). To develop this inventory, we have coupled a 1 km grid of per capita gross domestic product (GDP) estimates with market research data of HPC product sales. We explore the necessity of accounting for a population's ability to purchase HPC products in determining their subnational distribution in regions where wealth is not uniform. The implications of using high resolution data on inter- and intracountry subnational emission estimates for a range of hypothetical and actual HPC product types were explored. It was demonstrated that for low value products (500 US$ per capita/annum required to purchase product) the implications on emissions being assigned to subnational regions can vary by several orders of magnitude. The implications of this on conducting national or regional level risk assessments may be significant. Further work is needed to explore the implications of this variability in HPC emissions to enable the HPC industry and/or governments to advance risk-based chemical management policies in emerging markets. © 2013 SETAC.

  1. Optimization of operation for combined heat and power plants - CHP plants - with heat accumulators using a MILP formulation

    Energy Technology Data Exchange (ETDEWEB)

    Grue, Jeppe; Bach, Inger [Aalborg Univ. (Denmark). Inst. of Energy Technology]. E-mails: jeg@iet.auc.dk; ib@iet.auc.dk

    2000-07-01

    The power generation system in Denmark is extensively based on small combined heat and power plants (CHP plants), producing both electricity and district heating. This project deals with smaller plants spread throughout the country. Often a heat accumulator is used to enable electricity production, even when the heat demand is low. This system forms a very complex problem, both for sizing, designing and operation of CHP plants. The objective of the work is the development of a tool for optimisation of the operation of CHP plants, and to even considering the design of the plant. The problem is formulated as a MILP-problem. An actual case is being tested, involving CHP producing units to cover the demand. The results from this project show that it is of major importance to consider the operation of the plant in detail already in the design phase. It is of major importance to consider the optimisation of the plant operation, even at the design stage, as it may cause the contribution margin to rise significantly, if the plant is designed on the basis of a de-tailed knowledge of the expected operation. (author)

  2. City/industry/utility partnership leads to innovative combined heat and power project

    Energy Technology Data Exchange (ETDEWEB)

    Savage, J. [Savage and Associates, Quesnel, BC (Canada)

    2010-07-01

    This presentation discussed a combined heat and power (CHP) project that was launched in Quesnel, British Columbia. The CHP is being developed in phases in which new components will enter the system, providing added benefits. Hot oil from a sawmill bioenergy system will be used to heat lumber kilns, generate electricity at an Organic Rankine Cycle co-generation plant, and heat water for a District Energy Loop (DEL) to heat up to 22 existing buildings in the city as well as sawmill and planer buildings. The DEL piping would comprise a 5 kilometre loop. The energy would come from recovered sawmill space heating, recovered stack energy, and additional biomass energy. All of the district heating and 41 per cent of the power would be from heat recovered from the existing industrial operation. This bio-economy vision ultimately involves incorporating a biogas digester into the system to process food, regional organic waste, and pulp mill residuals, relying on bio-solids and heat from the mill. The fertilizer from the digester would then be used in a biomass plantation, which would provide materials to industry for many products, including bio-refining. This project evolved in response to concerns about the ecological effects and long-term economics of aggressive utilization of forest biomass. 15 figs.

  3. Methods for planning and operating decentralized combined heat and power plants

    Energy Technology Data Exchange (ETDEWEB)

    Palsson, H.

    2000-02-01

    In recent years, the number of decentralized combined heat and power (DCHP) plants, which are typically located in small communities, has grown rapidly. These relatively small plants are based on Danish energy resources, mainly natural gas, and constitute an increasing part of the total energy production in Denmark. The topic of this thesis is the analysis of DCHP plants, with the purpose to optimize the operation of such plants. This involves the modelling of district heating systems, which are frequently connected to DCHP plants, as well as the use of heat storage for balancing between heat and power production. Furthermore, the accumulated effect from increasing number of DCHP plants on the total power production is considered. Methods for calculating dynamic temperature response in district heating (DH) pipes have been reviewed and analyzed numerically. Furthermore, it has been shown that a tree-structured DH network consisting of about one thousand pipes can be reduced to a simple chain structure of ten equivalent pipes without loosing much accuracy when temperature dynamics are calculated. A computationally efficient optimization method based on stochastic dynamic programming has been designed to find an optimum start-stop strategy for a DCHP plant with a heat storage. The method focuses on how to utilize heat storage in connection with CHP production. A model for the total power production in Eastern Denmark has been applied to the accumulated DCHP production. Probability production simulations have been extended from the traditional power-only analysis to include one or several heat supply areas. (au)

  4. The prediction of gross calorific value using infrared (IR) spectroscopy and multivariate analysis

    Science.gov (United States)

    Chi-Leung So; Thomas L. Eberhardt

    2011-01-01

    The gross calorific value (GCV) of a fuel, also known as the higher heating value (HHV) or gross heat of combustion, is the amount of heat released by a specified quantity (initially at 25°C) once it is com-busted and the products returned to that temperature. Fuwape (1989) noted that extractive-free wood from Gmelina arborea (Roxb), a hardwood, had a lower gross heat...

  5. Exergy costing for energy saving in combined heating and cooling applications

    International Nuclear Information System (INIS)

    Nguyen, Chan; Veje, Christian T.; Willatzen, Morten; Andersen, Peer

    2014-01-01

    Highlights: • We investigate the basis for cost apportioning of simultaneous heating and cooling. • Two thermoeconomic methods based on energy and exergy costing is demonstrated. • The unit cost of heating and cooling for a heat pump system is found and compared. • Energy costing may obstruct efficient use of energy. • Exergy costing provides the most rational cost apportioning for energy saving. - Abstract: The aim of this study is to provide a price model that motivates energy saving for a combined district heating and cooling system. A novel analysis using two thermoeconomic methods for apportioning the costs to heating and cooling provided simultaneously by an ammonia heat pump is demonstrated. In the first method, referred to as energy costing, a conventional thermoeconomic analysis is used. Here the ammonia heat pump is subject to a thermodynamic analysis with mass and energy balance equations. In the second method referred to as exergy costing, an exergy based economic analysis is used, where exergy balance equations are used in conjunction with mass and energy balance equations. In both costing methods the thermodynamic analysis is followed by an economic analysis which includes investment and operating costs. For both methods the unit costs of heating and cooling are found and compared. The analysis shows that the two methods yield significantly different results. Rather surprisingly, it is demonstrated that the exergy costing method results in about three times higher unit cost for heating than for cooling as opposed to equal unit costs when using the energy method. Further the exergy-based cost for heating changes considerably with the heating temperature while that of cooling is much less affected

  6. Combined Heat Transfer in High-Porosity High-Temperature Fibrous Insulations: Theory and Experimental Validation

    Science.gov (United States)

    Daryabeigi, Kamran; Cunnington, George R.; Miller, Steve D.; Knutson, Jeffry R.

    2010-01-01

    Combined radiation and conduction heat transfer through various high-temperature, high-porosity, unbonded (loose) fibrous insulations was modeled based on first principles. The diffusion approximation was used for modeling the radiation component of heat transfer in the optically thick insulations. The relevant parameters needed for the heat transfer model were derived from experimental data. Semi-empirical formulations were used to model the solid conduction contribution of heat transfer in fibrous insulations with the relevant parameters inferred from thermal conductivity measurements at cryogenic temperatures in a vacuum. The specific extinction coefficient for radiation heat transfer was obtained from high-temperature steady-state thermal measurements with large temperature gradients maintained across the sample thickness in a vacuum. Standard gas conduction modeling was used in the heat transfer formulation. This heat transfer modeling methodology was applied to silica, two types of alumina, and a zirconia-based fibrous insulation, and to a variation of opacified fibrous insulation (OFI). OFI is a class of insulations manufactured by embedding efficient ceramic opacifiers in various unbonded fibrous insulations to significantly attenuate the radiation component of heat transfer. The heat transfer modeling methodology was validated by comparison with more rigorous analytical solutions and with standard thermal conductivity measurements. The validated heat transfer model is applicable to various densities of these high-porosity insulations as long as the fiber properties are the same (index of refraction, size distribution, orientation, and length). Furthermore, the heat transfer data for these insulations can be obtained at any static pressure in any working gas environment without the need to perform tests in various gases at various pressures.

  7. Modeling and optimization of a heat-pump-assisted high temperature proton exchange membrane fuel cell micro-combined-heat-and-power system for residential applications

    DEFF Research Database (Denmark)

    Arsalis, Alexandros; Kær, Søren Knudsen; Nielsen, Mads Pagh

    2015-01-01

    -CHP system assumes heat-led operation, to avoid dumping of heat and the use of complicated thermal energy storage. The overall system is grid-interconnected to allow importing and exporting of electricity as necessary. In this study emphasis is given on the operational characterization of the system......In this study a micro-combined-heat-and-power (micro-CHP) system is coupled to a vapor-compression heat pump to fulfill the residential needs for heating (space heating and water heating) and electricity in detached single-family households in Denmark. Such a combination is assumed to be attractive...... for application, since both fuel cell technology and electric heat pumps are found to be two of the most efficient technologies for generation/conversion of useful energy. The micro-CHP system is fueled with natural gas and includes a fuel cell stack, a fuel processor and other auxiliary components. The micro...

  8. Modelling of waste heat recovery for combined heat and power applications

    International Nuclear Information System (INIS)

    Descombes, Georges; Boudigues, Serge

    2009-01-01

    The current environmental context dictates to reduce the pollutant emissions by improving thermal efficiency of the energy production units. The authors present some studies of cogeneration applications using gas turbines and thermal engines. The on-going research concerns a detailed study of thermodynamic modelling cycles with energy recovery. These combined cycles with gas turbine and ICE can generate a potential increase of about 10% of the energy efficiency. They will generate a technological complexity and the over-charge must be estimated. At last, the authors insist on the necessary synergy between gas turbines and thermal engines.

  9. The development of Coke Carried-Heat Gasification Coal-Fired Combined Cycle

    Science.gov (United States)

    Zhao, Li; Xu, Xiangdong

    1999-12-01

    Carried-Heat Partial Gasification Combined cycle is a novel combined cycle which was proposed by Thermal Engineering Department of Tsinghua University in 1992. The idea of the system comes from the situation that the efficiency of the power plants in China is much lower than that of the advanced countries, but the coal consumption is much higher, which brings about the waste of primary energy resources and the pollution of the environment. With the deep study of the gasification technology, Coke Carried-Heat Gasification Coal-Fired Combined Cycle, as the improved system, came into birth in 1996 based on the partial gasification one. At the end of 1997, a new cycle scheme similar to IGCC was created. This paper focuses on several classes combined cycle put forward by Tsinghua University, depending on the plant configuration and carbon conversion, making the solution a viable and attractive option for efficient coal utilization.

  10. Study of a molten carbonate fuel cell combined heat, hydrogen and power system: Energy analysis

    International Nuclear Information System (INIS)

    Agll, Abdulhakim Amer A.; Hamad, Yousif M.; Hamad, Tarek A.; Thomas, Mathew; Bapat, Sushrut; Martin, Kevin B.; Sheffield, John W.

    2013-01-01

    Countries around the world are trying to use alternative fuels and renewable energy to reduce the energy consumption and greenhouse gas emissions. Biogas contains methane is considered a potential source of clean renewable energy. This paper discusses the design of a combined heat, hydrogen and power system, which generated by methane with use of Fuelcell, for the campus of Missouri University of Science and Technology located in Rolla, Missouri, USA. An energy flow and resource availability study was performed to identify sustainable type and source of feedstock needed to run the Fuelcell at its maximum capacity. FuelCell Energy's DFC1500 unit (a molten carbonate Fuelcell) was selected as the Fuelcell for the tri-generation (heat, hydrogen and electric power) system. This tri-generation system provides electric power to the campus, thermal energy for heating the anaerobic digester, and hydrogen for transportation, backup power and other applications on the campus. In conclusion, the combined heat, hydrogen and power system reduces fossil fuel usage, and greenhouse gas emissions at the university campus. -- Highlights: • Combined heat, hydrogen and power (CHHP) using a molten carbonate fuel cell. • Energy saving and alternative fuel of the products are determined. • Energy saving is increased when CHHP technology is implemented. • CHHP system reduces the greenhouse gas emissions and fuel consumption

  11. High-temperature thermocline TES combining sensible and latent heat - CFD modeling and experimental validation

    Science.gov (United States)

    Zavattoni, Simone A.; Geissbühler, Lukas; Barbato, Maurizio C.; Zanganeh, Giw; Haselbacher, Andreas; Steinfeld, Aldo

    2017-06-01

    The concept of combined sensible/latent heat thermal energy storage (TES) has been exploited to mitigate an intrinsic thermocline TES systems drawback of heat transfer fluid outflow temperature reduction during discharging. In this study, the combined sensible/latent TES prototype under investigation is constituted by a packed bed of rocks and a small amount of encapsulated phase change material (AlSi12) as sensible heat and latent heat sections respectively. The thermo-fluid dynamics behavior of the combined TES prototype was analyzed by means of a computational fluid dynamics approach. Due to the small value of the characteristic vessel-to-particles diameter ratio, the effect of radial void-fraction variation, also known as channeling, was accounted for. Both the sensible and the latent heat sections of the storage were modeled as porous media under the assumption of local thermal non-equilibrium (LTNE). The commercial code ANSYS Fluent 15.0 was used to solve the model's constitutive conservation and transport equations obtaining a fairly good agreement with reference experimental measurements.

  12. Expert Meeting Report: Recommendations for Applying Water Heaters in Combination Space and Domestic Water Heating Systems

    Energy Technology Data Exchange (ETDEWEB)

    Rudd, A.; Ueno, K.; Bergey, D.; Osser, R.

    2012-07-01

    The topic of this meeting was 'Recommendations For Applying Water Heaters In Combination Space And Domestic Water Heating Systems.' Presentations and discussions centered on the design, performance, and maintenance of these combination systems, with the goal of developing foundational information toward the development of a Building America Measure Guideline on this topic. The meeting was held at the Westford Regency Hotel, in Westford, Massachusetts on 7/31/2011.

  13. HEAT EXCHANGE AND AERODYNAMICS OF THE COMBINED TUBING BUNDLES WITH CROSS INCLINED FINS

    Directory of Open Access Journals (Sweden)

    Knyazyuk V. I

    2013-04-01

    Full Text Available The paper presents results of experimental research and analyses air-side thermal performance of combined tube bundles with cross inclined fins. The empirical correlations for heat transfer and flow friction of tubes with inclined fins at different orientation finned tubes relatively of air flow are presented. The errors of thermal and aerodynamic tests are 3-5% and 9.2%, respectively. The proposed correlations describe an experimental data with a coefficient of determination about 0.979-0.998. The impact of tubes arrangement in a bundle on energy performance of heat exchanger were analyzed using complete and local heat modeling methods at a stationary heat flux. Experimental research indicates that efficiency of inclined fins can be calculated by using the equation for cross rectangular fins with average deviation of ±5 %.

  14. An improved unit decommitment algorithm for combined heat and power systems

    DEFF Research Database (Denmark)

    Rong, Aiying; Lahdelma, R.; Grunow, Martin

    2009-01-01

    and a linear relaxation of the ON/OFF states of the plants. We compare the IUD algorithm with realistic test data against a generic unit decommitment (UD) algorithm. Numerical results show that IUD is an overall improvement of UD. The solution quality of IUD is better than that of UD for almost all of tested......This paper addresses the unit commitment in multi-period combined heat and power (CHP) production planning, considering the possibility to trade power on the spot market. In CHP plants (units), generation of heat and power follows joint characteristics, which means that production planning for both...... heat and power must be done in coordination. We present an improved unit decommitment (IUD) algorithm that starts with an improved initial solution with less heat surplus so that the relative cost-efficiency of the plants can be determined more accurately. Then the subsequent decommitment procedures...

  15. Hybrid Processing Combining Electrostatic Levitation and Laser Heating: Application to Terrestrial Analogues of Asteroid Materials

    Directory of Open Access Journals (Sweden)

    Paul-François Paradis

    2011-01-01

    Full Text Available Electrostatic levitation combined with laser heating is becoming a mature technique that has been used for several fundamental and applied studies in fluid and materials sciences (synthesis, property determination, solidification studies, atomic dynamic studies, etc.. This is attributable to the numerous processing conditions (containerless, wide heating temperature range, cooling rates, atmospheric compositions, etc. that levitation and radiative heating offer, as well as to the variety of diagnostics tools that can be used. In this paper, we describe the facility, highlighting the combined advantages of electrostatic levitation and laser processing. The various capabilities of the facility are discussed and are exemplified with the measurements of the density of selected iron-nickel alloys taken over the liquid phase.

  16. Planning the production of a fleet of domestic combined heat and power generators

    NARCIS (Netherlands)

    Bosman, M.G.C.; Bakker, Vincent; Molderink, Albert; Hurink, Johann L.; Smit, Gerardus Johannes Maria

    2012-01-01

    This paper describes a planning problem, arising in the energy supply chain, that deals with the planning of the production runs of micro combined heat and power (microCHP) appliances installed in houses, cooperating in a fleet. Two types of this problem are described. The first one is the Single

  17. Combined action of S-carvone and mild heat treatment on Listeria monocytogenes Scott A

    NARCIS (Netherlands)

    Karatzas, A.K.; Bennik, M.H.J.; Smid, E.J.; Kets, E.P.W.

    2000-01-01

    The combined action of the plant-derived volatile, S-carvone, and mild heat treatment on the food-borne pathogen, Listeria monocytogenes, was evaluated. The viability of exponential phase cultures grown at 8 °C could be reduced by 1.3 log units after exposure to S-carvone (5 mmol 1-1) for 30 min at

  18. Modelling Combined Heat Exchange in the Leading Edge of Perspective Aircraft Wing

    Directory of Open Access Journals (Sweden)

    Kandinsky Roman O.

    2015-01-01

    Full Text Available In this paper gas dynamic numerical modelling of leading edge flow is presented and thermal loading parameters are determined. Numerical modelling of combined radiative and conductive heat transfer of the wing edge is carried out, thermal state of structure is given and the results are analyzed.

  19. Diffusion of combined heat and power in Dutch greenhouses : A case study

    NARCIS (Netherlands)

    Dijkema, G.P.J.; Kasmire, J.; Van der Veen, R.A.C.

    2012-01-01

    This report presents the case study of the rapid diffusion of combined heat and power (CHP) units in the Dutch greenhouse horticulture in the period 2003-2009. The aim of the case study is to find explanations for this particular transition, and to generalize on the nature of technology diffusion

  20. Carbon Emissions Trading and Combined Heat and Power Strategies: Unintended Consequences

    Science.gov (United States)

    Tysseling, John C.; Vosevich, Mary; Boersma, Benjamin R.; Zumwalt, Jefferey A.

    2009-01-01

    Facility professionals continuously search for projects that reduce energy consumption and operating costs so as to directly benefit their bottom line. Many institutions nationwide have contemplated or made investments in combined heat and power (CHP) projects as a life-cycle strategy to minimize operating costs. However, recent sustainability and…

  1. Combining several thermal indices to generate a unique heat comfort assessment methodology

    Directory of Open Access Journals (Sweden)

    Wissam EL Hachem

    2015-11-01

    Full Text Available Purpose: The proposed methodology hopes to provide a systematic multi-disciplinary approach to assess the thermal environment while minimizing unneeded efforts. Design/methodology/approach: Different factors affect the perception of the human thermal experience: metabolic rate (biology, surrounding temperatures (heat balance and environmental factors and cognitive treatment (physiology.This paper proposes a combination of different multidisciplinary variables to generate a unique heat comfort assessment methodology. The variables at stake are physiological, biological, and environmental. Our own heat analysis is thoroughly presented and all relevant equations are described. Findings: Most companies are oblivious about potential dangers of heat stress accidents and thus about methods to monitor and prevent them. This methodology enables the company or the concerned individual to conduct a preliminary assessment with minimal wasted resources and time in unnecessary steps whilst providing a guideline for a detailed study with minimal error rates if needed. More so, thermal comfort is an integral part of sound ergonomics practices, which in turn are decisive for the success of any lean six sigma initiative. Research limitations/implications: This methodology requires several full implementations to finalize its design. Originality/value: Most used heat comfort models are inherently uncertain and tiresome to apply. An extensive literature review confirms the need for a uniform assessment methodology that combines the different thermal comfort models such as the Fanger comfort model (PMV, PPD and WGBT since high error rates coupled with tiresome calculations often hinder the thermal assessment process.

  2. Sustainable renewable energy seawater desalination using combined-cycle solar and geothermal heat sources

    KAUST Repository

    Missimer, Thomas M.

    2013-01-01

    Key goals in the improvement of desalination technology are to reduce overall energy consumption, make the process "greener," and reduce the cost of the delivered water. Adsorption desalination (AD) is a promising new technology that has great potential to reduce the need for conventional power, to use solely renewable energy sources, and to reduce the overall cost of water treatment. This technology can desalt seawater or water of even higher salinity using waste heat, solar heat, or geothermal heat. An AD system can operate effectively at temperatures ranging from 55 to 80 °C with perhaps an optimal temperature of 80 °C. The generally low temperature requirement for the feedwater allows the system to operate quite efficiently using an alternative energy source, such as solar power. Solar power, particularly in warm dry regions, can generate a consistent water temperature of about 90 °C. Although this temperature is more than adequate to run the system, solar energy collection only can occur during daylight hours, thereby necessitating the use of heat storage during nighttime or very cloudy days. With increasing capacity, the need for extensive thermal storage may be problematic and could add substantial cost to the development of an AD system. However, in many parts of the world, there are subsurface geothermal energy sources that have not been extensively used. Combining a low to moderate geothermal energy recovery system to an AD system would provide a solution to the thermal storage issue. However, geothermal energy development from particularly Hot Dry Rock is limited by the magnitude of the heat flow required for the process and the thermal conductivity of the rock material forming the heat reservoir. Combining solar and geothermal energy using an alternating 12-h cycle would reduce the probability of depleting the heat source within the geothermal reservoir and provide the most effective use of renewable energy. © 2013 Desalination Publications.

  3. Analysis of a combined heating and cooling system model under different operating strategies

    Science.gov (United States)

    Dzierzgowski, Mieczysław; Zwierzchowski, Ryszard

    2017-11-01

    The paper presents an analysis of a combined heating and cooling system model under different operating strategies. Cooling demand for air conditioning purposes has grown steadily in Poland since the early 1990s. The main clients are large office buildings and shopping malls in downtown locations. Increased demand for heat in the summer would mitigate a number of problems regarding District Heating System (DHS) operation at minimum power, affecting the average annual price of heat (in summertime the share of costs related to transport losses is a strong cost factor). In the paper, computer simulations were performed for different supply network water temperature, assuming as input, real changes in the parameters of the DHS (heat demand, flow rates, etc.). On the basis of calculations and taking into account investment costs of the Absorption Refrigeration System (ARS) and the Thermal Energy Storage (TES) system, an optimal capacity of the TES system was proposed to ensure smooth and efficient operation of the District Heating Plant (DHP). Application of ARS with the TES system in the DHS in question increases net profit by 19.4%, reducing the cooling price for consumers by 40%.

  4. Optimal Operation of Network-Connected Combined Heat and Powers for Customer Profit Maximization

    Directory of Open Access Journals (Sweden)

    Da Xie

    2016-06-01

    Full Text Available Network-connected combined heat and powers (CHPs, owned by a community, can export surplus heat and electricity to corresponding heat and electric networks after community loads are satisfied. This paper proposes a new optimization model for network-connected CHP operation. Both CHPs’ overall efficiency and heat to electricity ratio (HTER are assumed to vary with loading levels. Based on different energy flow scenarios where heat and electricity are exported to the network from the community or imported, four profit models are established accordingly. They reflect the different relationships between CHP energy supply and community load demand across time. A discrete optimization model is then developed to maximize the profit for the community. The models are derived from the intervals determined by the daily operation modes of CHP and real-time buying and selling prices of heat, electricity and natural gas. By demonstrating the proposed models on a 1 MW network-connected CHP, results show that the community profits are maximized in energy markets. Thus, the proposed optimization approach can help customers to devise optimal CHP operating strategies for maximizing benefits.

  5. A numerical investigation of combined heat storage and extraction in deep geothermal reservoirs

    DEFF Research Database (Denmark)

    Major, Márton; Poulsen, Søren Erbs; Balling, Niels

    2018-01-01

    Heat storage capabilities of deep sedimentary geothermal reservoirs are evaluated through numerical model simulations. We combine storage with heat extraction in a doublet well system when storage phases are restricted to summer months. The effects of stored volume and annual repetition on energy...... efficiency. Additional simulations concerning pressure build-up in the reservoir are carried out to show that safety levels may not be reached. Reservoir characteristics are inspired by Danish geothermal conditions, but results are assumed to have more general validity. Thus, deep sedimentary reservoirs...

  6. Thermoeconomic Analysis of Hybrid Power Plant Concepts for Geothermal Combined Heat and Power Generation

    Directory of Open Access Journals (Sweden)

    Florian Heberle

    2014-07-01

    Full Text Available We present a thermo-economic analysis for a low-temperature Organic Rankine Cycle (ORC in a combined heat and power generation (CHP case. For the hybrid power plant, thermal energy input is provided by a geothermal resource coupled with the exhaust gases of a biogas engine. A comparison to alternative geothermal CHP concepts is performed by considering variable parameters like ORC working fluid, supply temperature of the heating network or geothermal water temperature. Second law efficiency as well as economic parameters show that hybrid power plants are more efficient compared to conventional CHP concepts or separate use of the energy sources.

  7. Fin-and-tube heat exchanger enhancement with a combined herringbone and vortex generator design

    DEFF Research Database (Denmark)

    Välikangas, Turo; Singh, Shobhana; Sørensen, Kim

    2018-01-01

    Vortex generators (VGs) are the most commonly investigated enhancement methods in the field of improved heat exchangers. The aim of present work is to study the effect of VGs in a fin-and-tube heat exchanger (FTHE) with herringbone fin shape. The delta winglet VG design with length (s) and height...... (H) is selected based on previous studies. The investigated VG design is simple and considered realistic from the manufacturing point of view. The combined enhancement with herringbone fin and the VG is evaluated by simulating the conjugate heat transfer and the air flow. The structured mesh...... transfer in the herringbone fin but also decrease the pressure drop. The highest and longest investigated VG design is found to perform the best because of its ability to delay the flow detachment from the tube, to feed high kinetic energy flow to the recirculation zone and to create longitudinal vortices...

  8. Promoting investments in combined heat and power production in East-European countries

    International Nuclear Information System (INIS)

    Van Oostvoom, F.; Van Harmelen, T.

    1992-01-01

    The study concerns the evaluation of the potential of Combined Heat and Power (CHP) locations, both in industry and district heating with a heat demand of at least 20 GJ/h or ca. 1 MWe capacity. In fact 58 Hungarian locations were analyzed on scope and profitability for investment in CHP, using financial accounting models and criteria such as Internal Rate of Return and Pay-back Period. Due to the already existing favourable infrastructure in East European countries the present expectations in Hungary about the CHP capacity to be developed in the future are very optimistic (1300 up till 2000 MWe in the year 2000). Clearly there exist an overoptimism concerning the possibilities of increasing the energy efficiency in former East-European countries by investment in cogeneration. A more financially and economic attractive way for efficiency improvements is promoting energy saving in these countries and thus avoiding investments in supply technologies. 6 refs

  9. Optimization of systems with the combination of ground-source heat pump and solar collectors in dwellings

    DEFF Research Database (Denmark)

    Kjellsson, Elisabeth; Hellström, Göran; Perers, Bengt

    2010-01-01

    The use of ground-source heat pumps for heating and domestic hot water in dwellings is common in Sweden. The combination with solar collectors has been introduced to reduce the electricity demand in the system. In order to analyze different systems with combinations of solar collectors and ground-source...... heat pumps, computer simulations have been carried out with the simulation program TRNSYS. Large differences were found between the system alternatives. The optimal design is when solar heat produces domestic hot water during summertime and recharges the borehole during wintertime. The advantage...... is related to the rate of heat extraction from the borehole as well as the overall design of the system. The demand of electricity may increase with solar recharging, because of the increased operating time of the circulation pumps. Another advantage with solar heat in combination with heat pumps is when...

  10. Multi-objective optimization of a combined cooling, heating and power system driven by solar energy

    International Nuclear Information System (INIS)

    Wang, Man; Wang, Jiangfeng; Zhao, Pan; Dai, Yiping

    2015-01-01

    Highlights: • A solar-powered CCHP system using flat-plate solar collectors is modeled. • Multi-objective optimization are conducted to obtain optimum performance. • The system performance is obtained from thermodynamic and economic aspects. - Abstract: This paper presented a multi-objective optimization of a combined cooling, heating and power system (CCHP) driven by solar energy. The flat-plate solar collector was employed to collect the solar radiation and to transform it into thermal energy. The thermal storage unit was installed to storage the thermal energy collected by the collectors to ensure a continuous energy supplement when solar energy was weak or insufficient. The CCHP system combined an organic Rankine cycle with an ejector refrigeration cycle to yield electricity and cold capacity to users. In order to conduct the optimization, the mathematical model of the solar-powered CCHP system was established. Owing to the limitation of the single-objective optimization, the multi-objective optimization of the system was carried out. Four key parameters, namely turbine inlet temperature, turbine inlet pressure, condensation temperature and pinch temperature difference in vapor generator, were selected as the decision variables to examine the performance of the overall system. Two objective functions, namely the average useful output and the total heat transfer area, were selected to maximize the average useful output and to minimize the total heat transfer area under the given conditions. NSGA-II (Non-dominated Sort Genetic Algorithm-II) was employed to achieve the final solutions in the multi-objective optimization of the system operating in three modes, namely power mode, combined heat and power (CHP) mode, and combined cooling and power (CCP) mode. For the power mode, the optimum average useful output and total heat transfer area were 6.40 kW and 46.16 m 2 . For the CCP mode, the optimum average useful output and total heat transfer area were 5.84 k

  11. Evaluation of the performance of combined cooling, heating, and power systems with dual power generation units

    International Nuclear Information System (INIS)

    Knizley, Alta A.; Mago, Pedro J.; Smith, Amanda D.

    2014-01-01

    The benefits of using a combined cooling, heating, and power system with dual power generation units (D-CCHP) is examined in nine different U.S. locations. One power generation unit (PGU) is operated at base load while the other is operated following the electric load. The waste heat from both PGUs is used for heating and for cooling via an absorption chiller. The D-CCHP configuration is studied for a restaurant benchmark building, and its performance is quantified in terms of operational cost, primary energy consumption (PEC), and carbon dioxide emissions (CDE). Cost spark spread, PEC spark spread, and CDE spark spread are examined as performance indicators for the D-CCHP system. D-CCHP system performance correlates well with spark spreads, with higher spark spreads signifying greater savings through implementation of a D-CCHP system. A new parameter, thermal difference, is introduced to investigate the relative performance of a D-CCHP system compared to a dual PGU combined heat and power system (D-CHP). Thermal difference, together with spark spread, can explain the variation in savings of a D-CCHP system over a D-CHP system for each location. The effect of carbon credits on operational cost savings with respect to the reference case is shown for selected locations. - Highlights: • We investigate benefits from using combined cooling, heating, and power systems. • A dual power generation unit configuration is considered for CCHP and CHP. • Spark spreads for cost, energy, and emissions correlate with potential savings. • Thermal difference parameter helps to explain variations in potential savings. • Carbon credits may increase cost savings where emissions savings are possible

  12. Mitigation of Short-Lived Climate Pollutants from Residential Coal Heating and Combined Heating/Cooking Stoves: Impacts on the Cryosphere, Policy Options, and Co-benefits

    Science.gov (United States)

    Chafe, Z.; Anenberg, S.; Klimont, Z.; Kupiainen, K.; Lewis, J.; Metcalfe, J.; Pearson, P.

    2017-12-01

    Residential solid fuel combustion for cooking, heating, and other energy services contributes to indoor and outdoor air pollution, and creates impacts on the cryosphere. Solid fuel use often occurs in colder climates and at higher elevations, where a wide range of combustion emissions can reduce reflectivity of the snow- and ice-covered surfaces, causing climatic warming. Reducing short-lived climate pollutants (SLCPs), such as black carbon (BC), could have substantial climate and health co-benefits, especially in areas where emissions influence the cryosphere. A review of existing literature and emissions estimates, conducted as part of the Warsaw Summit on BC and Other Emissions from Residential Coal Heating Stoves and Combined Cooking/Heating Stoves, found little nationally-representative data on the fuels and technologies used for heating and combined cooking/heating. The GAINS model estimates that 24 million tonnes of coal equivalent were combusted by households for space heating globally in 2010, releasing 190 kilotons (kt) BC. Emissions from combined cooking/heating are virtually unknown. Policy instruments could mitigate cryosphere-relevant emissions of SLCPs from residential heating or cooking. These include indoor air quality guidelines, stove emission limits, bans on the use of specific fuels, regulatory codes that stipulate when burning can occur, stove changeout programs, and voluntary public education campaigns. These measures are being implemented in countries such as Chile (fuelwood moisture reduction campaign, energy efficiency, heating system improvements), Mongolia (stove renovation, fuel switching), Peru (improved stove programs), Poland (district heating, local fuel bans), United States (stove emission regulation) and throughout the European Community (Ecodesign Directive). Few, if any, of these regulations are likely to reduce emissions from combined cooking/heating. This research team found no global platform to create and share model

  13. Investigating the combined effects of heat and lighting on students reaction time in laboratory condition

    Directory of Open Access Journals (Sweden)

    Zohre Mohebian

    2016-12-01

    Full Text Available Introduction: In many workplaces there is exposure to heat and light simultaneously. This study investigated the combined effect of heat and lighting on some cognitive performance, i.e. reaction time. Methodology: the present semi-experimental study was conducted 2015 on 33 healthy students (16 girls and 17 boys with a mean age of 22.1 in the thermal stress chamber. The reaction time parameter by the reaction time measurement device, after exposure to different heat surfaces (dry temperatures 22 °C and 37 °C and lighting surfaces (200, 500 and 1500 lux. Data were analyzed using ANOVA test in SPSS-20. Results: The results showed that the average simple, diagnostic, two-color selective, two-sound selective reaction times and reaction time error increased after combined exposure to heat and lighting and showed a significant difference (P<0.05. The maximum score of reaction time belong to temperature of 37 c° and lighting of 1500 lux, the minimum score of reaction time belong to temperature of 22 °c and lighting of 1500 lux.

  14. Energy and environmental evaluation of combined cooling heating and power system

    Science.gov (United States)

    Bugaj, Andrzej

    2017-11-01

    The paper addresses issues involving problems of implementing combined cooling, heating and power (CCHP) system to industrial facility with well-defined demand profiles of cooling, heating and electricity. The application of CCHP system in this particular industrial facility is being evaluated by comparison with the reference system that consists of three conventional methods of energy supply: (a) electricity from external grid, (b) heat from gas-fired boilers and (c) cooling from vapour compression chillers run by electricity from the grid. The CCHP system scenario is based on the combined heat and power (CHP) plant with gas turbine-compressor arrangement and water/lithium bromide absorption chiller of a single-effect type. Those two scenarios are analysed in terms of annual primary energy usage as well as emissions of CO2. The results of the analysis show an extent of primary energy savings of the CCHP system in comparison with the reference system. Furthermore, the environmental impact of the CCHP usage, in the form of greenhouse gases emission reductions, compares quite favourably with the reference conventional option.

  15. Dynamic modeling and evaluation of solid oxide fuel cell - combined heat and power system operating strategies

    Science.gov (United States)

    Nanaeda, Kimihiro; Mueller, Fabian; Brouwer, Jacob; Samuelsen, Scott

    Operating strategies of solid oxide fuel cell (SOFC) combined heat and power (CHP) systems are developed and evaluated from a utility, and end-user perspective using a fully integrated SOFC-CHP system dynamic model that resolves the physical states, thermal integration and overall efficiency of the system. The model can be modified for any SOFC-CHP system, but the present analysis is applied to a hotel in southern California based on measured electric and heating loads. Analysis indicates that combined heat and power systems can be operated to benefit both the end-users and the utility, providing more efficient electric generation as well as grid ancillary services, namely dispatchable urban power. Design and operating strategies considered in the paper include optimal sizing of the fuel cell, thermal energy storage to dispatch heat, and operating the fuel cell to provide flexible grid power. Analysis results indicate that with a 13.1% average increase in price-of-electricity (POE), the system can provide the grid with a 50% operating range of dispatchable urban power at an overall thermal efficiency of 80%. This grid-support operating mode increases the operational flexibility of the SOFC-CHP system, which may make the technology an important utility asset for accommodating the increased penetration of intermittent renewable power.

  16. Design for micro-combined cooling, heating and power systems stirling engines and renewable power systems

    CERN Document Server

    2015-01-01

    ‘Design for Micro-Combined Cooling, Heating & Power Systems’ provides a manual for the technical and structural design of systems for supplying decentralised energy in residential buildings. It presents the micro-combined cooling, heating & power systems Stirling engines & renewable energy sources (mCCHP-SE-RES) systems in an accessible manner both for the public at large, and for professionals who conceive, design or commercialise such systems or their components.  The high performance levels of these systems are demonstrated within the final chapter by the results of an experiment in which a house is equipped with a mCCHP-SE-RES system. The reader is also familiarized with the conceptual, technical and legal aspects of modern domestic energy systems; the components that constitute these systems; and advanced algorithms for achieving the structural and technical design of such systems. In residential buildings, satisfying demands of durable development has gradually evolved from necessity to...

  17. Combined effect of ohmic heating and enzyme assisted aqueous extraction process on soy oil recovery.

    Science.gov (United States)

    Pare, Akash; Nema, Anurag; Singh, V K; Mandhyan, B L

    2014-08-01

    This research describes a new technological process for soybean oil extraction. The process deals with the combined effect of ohmic heating and enzyme assisted aqueous oil extraction process (EAEP) on enhancement of oil recovery from soybean seed. The experimental process consisted of following basic steps, namely, dehulling, wet grinding, enzymatic treatment, ohmic heating, aqueous extraction and centrifugation. The effect of ohmic heating parameters namely electric field strength (EFS), end point temperature (EPT) and holding time (HT) on aqueous oil extraction process were investigated. Three levels of electric field strength (i.e. OH600V, OH750V and OH900V), 3 levels of end point temperature (i.e. 70, 80 and 90 °C) and 3 levels of holding time (i.e. 0, 5 and 10 min.) were taken as independent variables using full factorial design. Percentage oil recovery from soybean by EAEP alone and EAEP coupled with ohmic heating were 53.12 % and 56.86 % to 73 % respectively. The maximum oil recovery (73 %) was obtained when the sample was heated and maintained at 90 °C using electric field strength of OH600V for a holding time of 10 min. The free fatty acid (FFA) of the extracted oil (i.e. in range of 0.97 to 1.29 %) was within the acceptable limit of 3 % (oleic acid) and 0.5-3 % prescribed respectively by PFA and BIS.

  18. Combined effects of chlorine dioxide, drying, and dry heat treatments in inactivating microorganisms on radish seeds.

    Science.gov (United States)

    Bang, Jihyun; Kim, Haeyoung; Kim, Hoikyung; Beuchat, Larry R; Ryu, Jee-Hoon

    2011-02-01

    We determined the combined effectiveness of ClO(2) (200 and 500 μg/ml, 5 min), air drying [25 °C, 40% relative humidity (RH), 2 h], and mild dry heat (55 °C, 23% RH, up to 48 h) treatments in killing total aerobic bacteria (TAB), Escherichia coli O157:H7, and molds and yeasts (MY) on radish seeds. A 5.1-log reduction in the number of TAB was achieved on radish seeds treated with 200 or 500 μg/ml ClO(2) followed by air drying for 2 h and dry heat treatment for 48 h or 24 h, respectively. When radish seeds were treated with 200 and 500 μg/ml ClO(2), air dried, and heat treated for 12 h and 6 h, respectively, the initial population of E. coli O157:H7 (5.6 log CFU/g) on seeds was reduced to an undetectable level (heat treatment up to 48 h. Results show that treating radish seeds with 500 μg/ml ClO(2), followed by air dried at 25 °C for 2 h and heat treatment at 55 °C for 36 h achieved a >5-log CFU/g reduction of TAB and E. coli O157:H7. These observations will be useful when developing effective strategies and practices to enhance the microbiological safety of radish sprouts. Copyright © 2010 Elsevier Ltd. All rights reserved.

  19. Decontamination of hospital wastes by the combined action of ionising radiation and heat - the thermorad process

    International Nuclear Information System (INIS)

    Icre, P.; Rocquigny, H. de

    1995-01-01

    The Thermorad process is used for decontaminating hospital wastes at the hospital as they are collected from the different departments. The process utilises the combined microbiological effects of ionising radiation (5 kGy) and dry heat (60 o C). The treatment unit, which is compact and of small size, contains a cobalt 60 source of under 100,000 curies and has an annual treatment capacity of 5000 m 3 . (author)

  20. Combined Heat and Power Systems for the Provision of Sustainable Energy from Biomass in Buildings

    Directory of Open Access Journals (Sweden)

    Ortwein Andreas

    2016-01-01

    Full Text Available Against the background of greenhouse gases causing climate change, combined heat and power (CHP systems fueled by biomass can efficiently supply energy with high flexibility. Such CHP systems will usually consist of one or more thermo-chemical conversion steps and at least one (the more or less separated electric power generation unit. Depending on the main products of the previous conversion steps (e.g. combustible gases or liquids, but also flue gases with sensible heat, different technologies are available for the final power conversion step. This includes steam cycles with steam turbines or engines and different working fluids (water, organic fluids, but also combustion based systems like gas turbines or gas engines. Further promising technologies include fuel cells with high electric efficiency. When integrating such CHP systems in buildings, there are different strategies, especially concerning electric power generation. While some concepts are focusing on base load production, others are regulated either by thermal or by electric power demand. The paper will give a systematic overview on the combination of thermo-chemical conversion of biomass and combined heat and power production technologies. The mentioned building integration strategies will be discussed, leading to conclusions for further research and development in that field.

  1. Determination of gross gamma and gross beta activities in liquid effluent samples. Phase I

    International Nuclear Information System (INIS)

    Curtis, K.E.; Sood, S.P.

    1985-08-01

    Several inadequacies in the presently used procedures for gross gamma and gross beta measurements in aqueous wastes have been identified. Both the presence of suspended particulate activity and the use of cesium-137 as a calibration standard can cause gross gamma measurements to overestimate the actual activity in the sample. At the same time, sample preparation for the determination of gross beta activities causes large losses of radioiodine before the measurement step and the presence of solid material can cause a serious decrease in the beta counting efficiency. A combination of these errors could result in large discrepancies between the results obtained by the two measurement methods. Improved procedures are required to overcome these problems

  2. Heat stress results in loss of chloroplast Cu/Zn superoxide dismutase and increased damage to Photosystem II in combined drought-heat stressed Lotus japonicus.

    Science.gov (United States)

    Sainz, Martha; Díaz, Pedro; Monza, Jorge; Borsani, Omar

    2010-09-01

    Drought and heat stress have been studied extensively in plants, but most reports involve analysis of response to only one of these stresses. Studies in which both stresses were studied in combination have less commonly been reported. We report the combined effect of drought and heat stress on Photosystem II (PSII) of Lotus japonicus cv. Gifu plants. Photochemistry of PSII was not affected by drought or heat stress alone, but the two stresses together decreased PSII activity as determined by fluorescence emission. Heat stress alone resulted in degradation of D1 and CP47 proteins, and D2 protein was also degraded by combined drought-heat stress. None of these proteins were degraded by drought stress alone. Drought alone induced accumulation of hydrogen peroxide but the drought-heat combination led to an increase in superoxide levels and a decrease in hydrogen peroxide levels. Furthermore, combined drought-heat stress was correlated with an increase in oxidative damage as determined by increased levels of thiobarbituric acid reactive substances. Heat also induced degradation of chloroplast Cu/Zn superoxide dismutase (SOD: EC 1.15.1.1) as shown by reduced protein levels and isozyme-specific SOD activity. Loss of Cu/Zn SOD and induction of catalase (CAT: EC 1.11.1.6) activity would explain the altered balance between hydrogen peroxide and superoxide in response to drought vs combined drought-heat stress. Degradation of PSII could thus be caused by the loss of components of chloroplast antioxidant defence systems and subsequent decreased function of PSII. A possible explanation for energy dissipation by L. japonicus under stress conditions is discussed.

  3. Gross decontamination experiment report

    Energy Technology Data Exchange (ETDEWEB)

    Mason, R.; Kinney, K.; Dettorre, J.; Gilbert, V.

    1983-07-01

    A Gross Decontamination Experiment was conducted on various levels and surfaces of the TMI - Unit 2 reactor building in March 1982. The polar crane, D-rings, missile shields, refueling canals, refueling bridges, equipment, and elevations 305' and 347'-6'' were flushed with low pressure water. Additionally, floor surfaces on elevation 305' and floor surfaces and major pieces of equipment on elevation 347'-6'' were sprayed with high pressure water. Selective surfaces were decontaminated with a mechanical scrubber and chemicals. Strippable coating was tested and evaluated on equipment and floor surfaces. The effectiveness, efficiency, and safety of several decontamination techniques were established for the large, complex decontamination effort. Various decontamination equipment was evaluated and its effectiveness was documented. Decontamination training and procedures were documented and evaluated, as were the support system and organization for the experiment.

  4. Gross decontamination experiment report

    International Nuclear Information System (INIS)

    Mason, R.; Kinney, K.; Dettorre, J.; Gilbert, V.

    1983-07-01

    A Gross Decontamination Experiment was conducted on various levels and surfaces of the TMI - Unit 2 reactor building in March 1982. The polar crane, D-rings, missile shields, refueling canals, refueling bridges, equipment, and elevations 305' and 347'-6'' were flushed with low pressure water. Additionally, floor surfaces on elevation 305' and floor surfaces and major pieces of equipment on elevation 347'-6'' were sprayed with high pressure water. Selective surfaces were decontaminated with a mechanical scrubber and chemicals. Strippable coating was tested and evaluated on equipment and floor surfaces. The effectiveness, efficiency, and safety of several decontamination techniques were established for the large, complex decontamination effort. Various decontamination equipment was evaluated and its effectiveness was documented. Decontamination training and procedures were documented and evaluated, as were the support system and organization for the experiment

  5. Combined facial heating and inhalation of hot air do not alter thermoeffector responses in humans

    Science.gov (United States)

    Wingo, Jonathan E.; Low, David A.; Keller, David M.; Kimura, Kenichi

    2015-01-01

    The influence of thermoreceptors in human facial skin on thermoeffector responses is equivocal; furthermore, the presence of thermoreceptors in the respiratory tract and their involvement in thermal homeostasis has not been elucidated. This study tested the hypothesis that hot air directed on the face and inhaled during whole body passive heat stress elicits an earlier onset and greater sensitivity of cutaneous vasodilation and sweating than that directed on an equal skin surface area away from the face. Six men and two women completed two trials separated by ∼1 wk. Participants were passively heated (water-perfused suit; core temperature increase ∼0.9°C) while hot air was directed on either the face or on the lower leg (counterbalanced). Skin blood flux (laser-Doppler flowmetry) and local sweat rate (capacitance hygrometry) were measured at the chest and one forearm. During hot-air heating, local temperatures of the cheek and leg were 38.4 ± 0.8°C and 38.8 ± 0.6°C, respectively (P = 0.18). Breathing hot air combined with facial heating did not affect mean body temperature onsets (P = 0.97 and 0.27 for arm and chest sites, respectively) or slopes of cutaneous vasodilation (P = 0.49 and 0.43 for arm and chest sites, respectively), or the onsets (P = 0.89 and 0.94 for arm and chest sites, respectively), or slopes of sweating (P = 0.48 and 0.65 for arm and chest sites, respectively). Based on these findings, respiratory tract thermoreceptors, if present in humans, and selective facial skin heating do not modulate thermoeffector responses during passive heat stress. PMID:26157054

  6. Simulation of a solar assisted combined heat pump – Organic rankine cycle system

    International Nuclear Information System (INIS)

    Schimpf, Stefan; Span, Roland

    2015-01-01

    Highlights: • Addition of an ORC to a solar thermal and ground source heat pump system. • Reverse operation of the scroll compressor in ORC mode. • Annual simulations for application in a single-family house at three locations. • By introducing the ORC the net electricity demand is reduced by 1–9%. • Over the lifetime of the system savings can cover additional investments. - Abstract: A novel solar thermal and ground source heat pump system that harnesses the excess heat of the collectors during summer by an Organic Rankine Cycle (ORC) is simulated. For the ORC the heat pump process is reversed. In this case the scroll compressor of the heat pump runs as a scroll expander and the working fluid is condensed in the ground heat exchanger. Compared to a conventional solar thermal system the only additional investments for the combined system are a pump, valves and upgraded controls. The goal of the study is to simulate and optimize such a system. A brief overview of the applied models and the evolutionary algorithm for the optimization is given. A system with 12 m 2 of flat plate collectors installed in a single family house is simulated for the locations Ankara, Denver and Bochum. The ORC benefits add up to 20–140 kW h/a, which reduces the net electricity demand of the system by 1–9%. Overall 180–520 € are saved over a period of 20 years, which can be enough to cover the additional investments

  7. A combined power cycle utilizing low-temperature waste heat and LNG cold energy

    International Nuclear Information System (INIS)

    Shi Xiaojun; Che Defu

    2009-01-01

    This paper has proposed a combined power system, in which low-temperature waste heat can be efficiently recovered and cold energy of liquefied natural gas (LNG) can be fully utilized as well. This system consists of an ammonia-water mixture Rankine cycle and an LNG power generation cycle, and it is modelled by considering mass, energy and species balances for every component and thermodynamic analyses are conducted. The results show that the proposed combined cycle has good performance, with net electrical efficiency and exergy efficiency of 33% and 48%, respectively, for a typical operating condition. The power output is equal to 1.25 MWh per kg of ammonia-water mixture. About 0.2 MW of electrical power for operating sea water pumps can be saved. Parametric analyses are performed for the proposed combined cycle to evaluate the effects of key factors on the performance of the proposed combined cycle through simulation calculations. Results show that a maximum net electrical efficiency can be obtained as the inlet pressure of ammonia turbine increases and the peak value increases as the ammonia mass fraction increases. Exergy efficiency goes up with the increased ammonia turbine inlet pressure. With the ammonia mass fraction increases, the net electrical efficiency increases, whereas exergy efficiency decreases. For increasing LNG turbine inlet pressure or heat source temperature, there is also a peak of net electrical efficiency and exergy efficiency. With the increase of LNG gas turbine outlet pressure, exergy efficiency increases while net electrical efficiency drops

  8. Modulation of Antioxidant Defense System Is Associated with Combined Drought and Heat Stress Tolerance in Citrus

    Directory of Open Access Journals (Sweden)

    Sara I. Zandalinas

    2017-06-01

    Full Text Available Drought and high temperatures are two major abiotic stress factors that often occur simultaneously in nature, affecting negatively crop performance and yield. Moreover, these environmental challenges induce oxidative stress in plants through the production of reactive oxygen species (ROS. Carrizo citrange and Cleopatra mandarin are two citrus genotypes with contrasting ability to cope with the combination of drought and heat stress. In this work, a direct relationship between an increased antioxidant activity and stress tolerance is reported. According to our results, the ability of Carrizo plants to efficiently coordinate superoxide dismutase (SOD, ascorbate peroxidase (APX, catalase (CAT, and glutathione reductase (GR activities involved in ROS detoxification along with the maintenance of a favorable GSH/GSSG ratio could be related to their relative tolerance to this stress combination. On the other hand, the increment of SOD activity and the inefficient GR activation along with the lack of CAT and APX activities in Cleopatra plants in response to the combination of drought and heat stress, could contribute to an increased oxidative stress and the higher sensibility of this citrus genotype to this stress combination.

  9. Modulation of Antioxidant Defense System Is Associated with Combined Drought and Heat Stress Tolerance in Citrus.

    Science.gov (United States)

    Zandalinas, Sara I; Balfagón, Damián; Arbona, Vicent; Gómez-Cadenas, Aurelio

    2017-01-01

    Drought and high temperatures are two major abiotic stress factors that often occur simultaneously in nature, affecting negatively crop performance and yield. Moreover, these environmental challenges induce oxidative stress in plants through the production of reactive oxygen species (ROS). Carrizo citrange and Cleopatra mandarin are two citrus genotypes with contrasting ability to cope with the combination of drought and heat stress. In this work, a direct relationship between an increased antioxidant activity and stress tolerance is reported. According to our results, the ability of Carrizo plants to efficiently coordinate superoxide dismutase (SOD), ascorbate peroxidase (APX), catalase (CAT), and glutathione reductase (GR) activities involved in ROS detoxification along with the maintenance of a favorable GSH/GSSG ratio could be related to their relative tolerance to this stress combination. On the other hand, the increment of SOD activity and the inefficient GR activation along with the lack of CAT and APX activities in Cleopatra plants in response to the combination of drought and heat stress, could contribute to an increased oxidative stress and the higher sensibility of this citrus genotype to this stress combination.

  10. Combined use of solar heat and cogeneration - a perspective for district heating?; Kombinierter Einsatz von solarer Waerme und Kraft-Waerme-Kopplung - eine Perspektive fuer die Nahwaerme?

    Energy Technology Data Exchange (ETDEWEB)

    Entress, J. [Deutsches Zentrum fuer Luft- und Raumfahrt (DLR), Stuttgart (Germany). Abt. Systemanalyse und Technikbewertung; Steinborn, F. [Zentrum fuer Sonnenenergie- und Wasserstoff-Forschung Baden-Wuerttemberg (ZSW), Stuttgart (Germany). Fachgebiet Systemanalyse

    1998-02-01

    With Cogeneration of Heat and Power (CHP), climate-endangering CO{sub 2}-emissions can be reduced singificantly. The heat produced can be delivered at prices comparable to those of conventionally produced heat. With solar district heating, yet higher CO{sub 2}-savings are possible but at higher cost. Promising is a combination of CHP and solar district heating: The heat storage of the solar system can be used to level out heat demand, leading to smooth CHP operation, while heat generated by CHP can be used to substitute for low irradiation during the winter period. However, calculations together with simulation and optimization indicate that combining CHP and solar district heating is not the optimal solution in all cases. (orig.) [Deutsch] Der Einsatz von Blockheizkraftwerken (BHKW) kann zu einer deutlichen Reduzierung der klimagefaehrdenden CO{sub 2}-Emissionen beitragen. Dabei kann die ausgekoppelte Waerme etwa zum gleichen Preis wie konventionell erzeugte Waerme abgegeben werden. Hoehere CO{sub 2}-Einsparungen lassen sich hingegen mit solarer Nahwaerme erzielen, allerdings zu hoeheren Kosten. Eine Kombination dieser beiden Waermetechniken verspricht Vorteile: Einerseits kann der Waermespeicher des Solarsystems auch zum Ausgleich von Lastspitzen beim Betrieb des BHKW`s genutzt werden. Andererseits kann die waehrend der einstrahlungsarmen Wintermonate fehlende solare Waerme durch das BHKW erzeugt werden. Detaillierte Simulations- und Optimierungsrechnungen zeigen jedoch, dass eine Kombination dieser Waermetechniken nicht immer empfehlenswert ist. (orig.)

  11. Guide to Combined Heat and Power Systems for Boiler Owners and Operators

    Energy Technology Data Exchange (ETDEWEB)

    Oland, CB

    2004-08-19

    Combined heat and power (CHP) or cogeneration is the sequential production of two forms of useful energy from a single fuel source. In most CHP applications, chemical energy in fuel is converted to both mechanical and thermal energy. The mechanical energy is generally used to generate electricity, while the thermal energy or heat is used to produce steam, hot water, or hot air. Depending on the application, CHP is referred to by various names including Building Cooling, Heating, and Power (BCHP); Cooling, Heating, and Power for Buildings (CHPB); Combined Cooling, Heating, and Power (CCHP); Integrated Energy Systems (IES), or Distributed Energy Resources (DER). The principal technical advantage of a CHP system is its ability to extract more useful energy from fuel compared to traditional energy systems such as conventional power plants that only generate electricity and industrial boiler systems that only produce steam or hot water for process applications. By using fuel energy for both power and heat production, CHP systems can be very energy efficient and have the potential to produce electricity below the price charged by the local power provider. Another important incentive for applying cogeneration technology is to reduce or eliminate dependency on the electrical grid. For some industrial processes, the consequences of losing power for even a short period of time are unacceptable. The primary objective of the guide is to present information needed to evaluate the viability of cogeneration for new or existing industrial, commercial, and institutional (ICI) boiler installations and to make informed CHP equipment selection decisions. Information presented is meant to help boiler owners and operators understand the potential benefits derived from implementing a CHP project and recognize opportunities for successful application of cogeneration technology. Topics covered in the guide follow: (1) an overview of cogeneration technology with discussions about benefits

  12. Antimicrobial activity of suspensions and nanoemulsions of citral in combination with heat or pulsed electric fields.

    Science.gov (United States)

    Pagán, E; Berdejo, D; Espina, L; García-Gonzalo, D; Pagán, R

    2018-01-01

    The application of essential oils in form of nanoemulsions has been proposed as a method to improve their solubility in aqueous solutions, and hence their antimicrobial activity. The objective of this study was to evaluate the antimicrobial activity of citral, applied directly or in combined treatments with heat or pulsed electric fields (PEF), as a function of the inoculation procedure assayed: (i) a simple, vigorous shaking method by vortex agitation (suspension of citral; s-citral) or (ii) the previous preparation of nanoemulsions by the emulsion phase inversion (EPI) method (nanoemulsion of citral; n-citral). n-Citral was more effective in either inhibiting or inactivating Escherichia coli O157:H7 Sakai than s-citral. However, when combined with heat, a greater synergistic effect was observed with s-citral rather than with n-citral, either in lab media (pH 7·0 and 4·0) or apple juice. For instance, while almost 5 log 10 cell cycles were inactivated in apple juice after 15 min at 53°C in the presence of 0·1 μl ml -1 of s-citral, the use of n-citral required 30 min. The use of nanoemulsions did not modify the slight synergism observed when citral and mild PEF were combined (150 μs, 30 kV cm -1 ). The exploration of different delivery systems of antimicrobial compounds such as citral in aqueous food products aids in the establishment of successful combined treatments for food preservation. While at room temperature, citral in form of a nanoemulsion shows a higher antimicrobial activity; its combination with heat would imply a partial loss of the outstanding synergistic lethal effect achieved when added in suspension form. Therefore, the most suitable procedure to magnify the synergism between heat and citral when processing juices would merely require an intense homogenization step prior to the combined treatment. © 2017 The Society for Applied Microbiology.

  13. Simulation model of the combined production of low-temperature heat and electricity

    Energy Technology Data Exchange (ETDEWEB)

    Verbruggen, A.

    1979-10-01

    This article summarizes part of the research carried out by the author with respect to district heating. Only a production submodel is discussed. With respect to the state of the art as reflected in the BMFT Gesamtstudie and the Fernwaerme International journal, the model is an improvement on the following points: (1) the computations are carried out with the help of a set of analytical functions derived from the heat load duration curve and (2) the impact of the exhaust steam temperature levels at the turbines is studied in detail. The integration of the temperature variable into the analysis is twofold: -the gliding temperature exploitation mode is simulated; -the 'temperature topping' operation is integrated into the analysis. No simultaneous optimization of the dh system and the elctricity system is undertaken, because no information as to the synchronism of the demand for both products is available. Heat supply costs are minimized subject to a joint cost allocation principle, ensuring district heating to be a neutral activity as to the electric utilities, i.e., electricity production and capacity forthcoming from combined plants are compensated at the long-run marginal costs of the electric system.

  14. Combined heat and power generation with a HCPV system at 2000 suns

    International Nuclear Information System (INIS)

    Paredes, Filippo; Montagnino, Fabio M.; Milone, Sergio; Salinari, Piero; Agnello, Simonpietro; Gelardi, Franco M.; Sciortino, Luisa; Cannas, Marco; Bonsignore, Gaetano; Barbera, Marco; Collura, Alfonso; Lo Cicero, Ugo

    2015-01-01

    This work shows the development of an innovative solar CHP system for the combined production of heat and power based upon HCPV modules working at the high concentration level of 2000 suns. The solar radiation is concentrated on commercial InGaP/InGaAs/Ge triple-junction solar cells designed for intensive work. The primary optics is a rectangular off-axis parabolic mirror while a secondary optic at the focus of the parabolic mirror is glued in optical contact with the cell. Each module consist of 2 axis tracker (Alt-Alt type) with 20 multijunction cells each one integrated with an active heat sink. The cell is connected to an active heat transfer system that allows to keep the cell at a high level of electrical efficiency (ηel > 30 %), bringing the heat transfer fluid (water and glycol) up to an output temperature of 90°C. Accordingly with the experimental data collected from the first 1 kWe prototype, the total amount of extracted thermal energy is above the 50% of the harvested solar radiation. That, in addition the electrical efficiency of the system contributes to reach an overall CHP efficiency of more than the 80%

  15. An effective heuristic for combined heat-and-power production planning with power ramp constraints

    International Nuclear Information System (INIS)

    Rong, Aiying; Lahdelma, Risto

    2007-01-01

    Combined heat-and-power (CHP) production is an increasingly important technology for its efficient utilization of primary-energy resources and for reducing CO 2 emissions. In the CHP plant, the generation of heat-and-power follows a joint characteristic, which makes the determination of both the marginal power production cost (MPPC) and the feasible operating region for the plant more complicated than for the power-only generation plant. Due to the interdependence between heat and power production, the power-ramp constraints, which limit how much the power production of a CHP plant may increase or decrease between two successive periods, may also imply constraints on the heat production. In this paper, we investigate the impact of power-ramp constraints on CHP production planning and develop a robust heuristic for dealing with the power-ramp constraints based on the solution to the problem with relaxed ramp-constraints (RRC). Numerical results based on realistic production models show that the heuristic can generate high-quality solutions efficiently. (author)

  16. Combined action of S-carvone and mild heat treatment on Listeria monocytogenes Scott A.

    Science.gov (United States)

    Karatzas, A K; Bennik, M H; Smid, E J; Kets, E P

    2000-08-01

    The combined action of the plant-derived volatile, S-carvone, and mild heat treatment on the food-borne pathogen, Listeria monocytogenes, was evaluated. The viability of exponential phase cultures grown at 8 degrees C could be reduced by 1.3 log units after exposure to S-carvone (5 mmol l-1) for 30 min at 45 degrees C, while individual treatment with S-carvone or exposure to 45 degrees C for 30 min did not result in a loss in viability. Other plant-derived volatiles, namely carvacrol, cinnamaldehyde, thymol and decanal, were also found to reduce the viability of L. monocytogenes in combination with the same mild heat treatment at concentrations of 1.75 mmol l-1, 2.5 mmol l-1, 1.5 mmol l-1 and 2 mmol l-1, respectively. These findings show that essential oil compounds can play an important role in minimally processed foods, and can be used in the concept of Hurdle Technology to reduce the intensity of heat treatment or other individual hurdles.

  17. Heat pump system for summer houses if possible combined with solar heating; Varmepumpeanlaeg til fritidshus eventuelt i kombination med solvarme

    Energy Technology Data Exchange (ETDEWEB)

    Ellehauge, K.; Kildemoes, T.; Kristensen, Joern; Bjergen Jensen, T.

    2006-03-15

    Denmark has about 220.000 summer cottages and it is estimated that about 10% of these are for rental. The trend within summer cottages for rental is going towards more and more facilities and intensive rental, and as a consequence of this high energy consumption. A substantial part of the energy use is for heating, i.e. space heating, heating of indoor pool and domestic hot water. Contrary to the other building stock in Denmark summer cottages nearly always use electricity for heating. In the project it is found, that the average yearly electricity use of a summer cottage for rental with indoor pool is about 31.000 kWh. In the project typical energy consumption profiles have been set up from analyses of typical equipment and from simulation of space heat demands in Danish climate. Furthermore a number of heat delivery solutions with heat pumps and solar heating systems have been set up and the performance has been simulated and analysed. As a result of the analyses 2 prototype systems both consisting of an air to air heat pump for space heating and an air to water heat pump for the hot water, the spa and the pool heating has been installed and tested in two summer cottages. There is a good economy in the systems and these are therefore marketed by the project participants, Energi Danmark NRGi (energy utility) and Dansommer (cottage rental company). (au)

  18. Thermoeconomic Optimization of a Combined Heating and Humidification Coil for HVAC Systems

    Science.gov (United States)

    Teodoros, Liliana; Andresen, Bjarne

    2016-07-01

    The total cost of ownership is calculated for a combined heating and humidification coil of an air-handling unit taking into account investment and operation costs simultaneously. This total cost represents the optimization function for which the minimum is sought. The parameters for the cost dependencies are the physical dimensions of the coil: length, width and height. The term "coil" is used generically since in this setup it generates heating as well as humidification in a single unit. The first part of the paper deals with the constructive optimization and finds the relationship between the dimensions for a minimum cost. The second part of the paper takes the results of the constructive optimization further and, based on the data derived in our previous papers, analyzes the minimum total cost for the humidification coil while balancing the amount of water used to humidify the air and modify its temperature.

  19. Exergy analysis of a combined heat and power plant with integrated lignocellulosic ethanol production

    DEFF Research Database (Denmark)

    Lythcke-Jørgensen, Christoffer Ernst; Haglind, Fredrik; Clausen, Lasse Røngaard

    2014-01-01

    Lignocellulosic ethanol production is often assumed integrated in polygeneration systems because of its energy intensive nature. The objective of this study is to investigate potential irreversibilities from such integration, and what impact it has on the efficiency of the integrated ethanol...... production. An exergy analysis is carried out for a modelled polygeneration system in which lignocellulosic ethanol production based on hydrothermal pretreatment is integrated in an existing combined heat and power (CHP) plant. The ethanol facility is driven by steam extracted from the CHP unit when feasible...... in the ethanol facility. The calculated standard exergy efficiency of the ethanol facility varied from 0.564 to 0.855, of which the highest was obtained for integrated operation at reduced CHP load and full district heating production in the ethanol facility, and the lowest for separate operation with zero...

  20. Prospects for city-scale combined heat and power in the UK

    Energy Technology Data Exchange (ETDEWEB)

    Nelson, John [Finnpower, High Wycombe (United Kingdom); Amos, John [Hoare Lea and Partners, Bristol (United Kingdom); Hutchinson, David [London Research Centre (United Kingdom); Denman, Malcolm [Sheffield Hallam Univ. (United Kingdom). School of Engineering

    1996-07-01

    City-scale combined heat and power/district heating (CHP/DH) brings to a number of European countries major social and commercial benefits which have been almost totally overlooked in the UK. To bring CHP/DH to the UK, it is necessary first to convince people of the benefits and then to persuade the Government to introduce the necessary legislation to allow the establishment of true city energy utilities on European lines. Neither task will be easy because of the resultant effect on the British fuel industries. The necessary changes must inevitably be gradual and there would, in any case, be a substantial role for the fuel industries - which they must be made aware of. (author)

  1. Hybrid DE-SQP Method for Solving Combined Heat and Power Dynamic Economic Dispatch Problem

    Directory of Open Access Journals (Sweden)

    A. M. Elaiw

    2013-01-01

    Full Text Available Combined heat and power dynamic economic dispatch (CHPDED plays a key role in economic operation of power systems. CHPDED determines the optimal heat and power schedule of committed generating units by minimizing the fuel cost under ramp rate constraints and other constraints. Due to complex characteristics, heuristic and evolutionary based optimization approaches have became effective tools to solve the CHPDED problem. This paper proposes hybrid differential evolution (DE and sequential quadratic programming (SQP to solve the CHPDED problem with nonsmooth and nonconvex cost function due to valve point effects. DE is used as a global optimizer and SQP is used as a fine tuning to determine the optimal solution at the final. The proposed hybrid DE-SQP method has been tested and compared to demonstrate its effectiveness.

  2. A variant of the dynamic programming algorithm for unit commitment of combined heat and power systems

    DEFF Research Database (Denmark)

    Rong, Aiying; Hakonen, Henri; Lahdelma, Risto

    2008-01-01

    The paper addresses the unit commitment in multi-period combined heat and power (CHP) production planning under the deregulated power market. In CHP plants (units), generation of heat and power follows joint characteristics, which means that production planning must be done in coordination. We...... in the system, the number of periods over the planning horizon and the time for solving a single-period economic dispatch problem. We have compared the DP-RSC1 algorithm with realistic power plants against the unit decommitment algorithm and the traditional priority listing method. The results show that the DP...... introduce in this paper the DP-RSC1 algorithm, which is a variant of the dynamic programming (DP) algorithm based on linear relaxation of the ON/OFF states of the units and sequential commitment of units one by one. The time complexity of DP-RSC1 is proportional to the number of generating units...

  3. Optimization of micro combined heat and power gas turbine by genetic algorithm

    Directory of Open Access Journals (Sweden)

    Yazdi Behnam Ahrar

    2015-01-01

    Full Text Available In this paper, a comprehensive thermodynamic modeling and multi-objective optimization of a micro turbine cycle in combined heat and power generation, which provides 100KW of electric power. This CHP System is composed of air compressor, combustion chamber (CC, Air Preheater, Gas Turbine (GT and a Heat Recovery Heat Exchanger. In this paper, at the first stage, the each part of the micro turbine cycle is modeled using thermodynamic laws. Next, with using the energetic and exergetic concepts and applying economic and environmental functions, the multi-objectives optimization of micro turbine in combined heat and power generation is performed. The design parameters of this cycle are compressor pressure ratio (rAC, compressor isentropic efficiency (ηAC, GT isentropic efficiency (ηGT, CC inlet temperature (T3, and turbine inlet temperature (T4. In the multi-objective optimization three objective functions, including CHP exergy efficiency, total cost rate of the system products, and CO2 emission of the whole plant, are considered. Theexergoenvironmental objective function is minimized whereas power plant exergy efficiency is maximized usinga Genetic algorithm. To have a good insight into this study, a sensitivity analysis of the result to the fuel cost is performed. The results show that at the lower exergetic efficiency, in which the weight of exergo-environmental objective is higher, the sensitivity of the optimal solutions to the fuel cost is much higher than the location of the Pareto Frontier with the lower weight of exergo-environmental objective. In addition, with increasing exergy efficiency, the purchase cost of equipment in the plant is increased as the cost rate of the plant increases.

  4. Analysis of two solar heating systems for combined space heating and domestic hot water preparation in multi-family houses

    International Nuclear Information System (INIS)

    Schlaepfer, B.; Ruesch, H.; Bremer, P.; Calatayud, C.; Nilsson, M.O.; Keller, L.

    1986-01-01

    Within the framework of a large research project dealing with the optimization of solar heating systems from the points of view of heat storage management, heat store and hydraulics' design as well as control algorithms, solar heating plants were installed in two identical refurbished multi-family houses located side-by-side at Duebendorf, Switzerland. The refurbishment works included new windows and doors, a new facades' thermal insulation, further thermal insulation applied to cellar and attic and a new oil-fired boiler. The two solar plants had identical solar collector arrays, but differed in the heat store and hydraulics design. In the first one the heat produced by the oil boiler is supplied to the same store as the heat from the collectors. In the second one the heat production of the oil boiler is directly supplied to the heat consumers, and also the solar heat may be directed to the floor heating through a store by-pass. The two systems were monitored for one year. Monitoring results indicate that the second system has, indeed, some advantages from the point of view of increased solar output from the collectors. But in the climate of Zurich and that type of retrofitted houses the larger heat production still has to come from the oil boiler and the major optimization potential for energy savings lies in the boiler's operational efficiency and a good management of the heat it produces. The solar fraction was about 20%. The report also includes cost figures for both systems. This pioneering comparative evaluation of two solar heating system designs contains data still of interest 17 years on

  5. Long-term optimization case studies for combined heat and power system

    Directory of Open Access Journals (Sweden)

    Polyzakis Apostolis L.

    2009-01-01

    Full Text Available In the next years distributed poly-generation systems are expected to play an increasingly important role in the electricity infrastructure and market. The successful spread of small-scale generation either connected to the distribution network or on the customer side of the meter depends on diverse issues, such as the possibilities of technical implementation, resource availability, environmental aspects, and regulation and market conditions. The aim of this approach is to develop an economic and parametric analysis of a distributed generation system based on gas turbines able to satisfy the energy demand of a typical hotel complex. Here, the economic performance of six cases combining different designs and regimes of operation is shown. The software Turbomatch, the gas turbine performance code of Cranfield University, was used to simulate the off-design performance of the engines in different ambient and load conditions. A clear distinction between cases running at full load and following the load could be observed in the results. Full load regime can give a shorter return on the investment then following the load. In spite combined heat and power systems being currently not economically attractive, this scenario may change in future due to environmental regulations and unavailability of low price fuel for large centralized power stations. Combined heat and power has a significant potential although it requires favorable legislative and fair energy market conditions to successfully increase its share in the power generation market.

  6. Investigation of drag and heat reduction induced by a novel combinational lateral jet and spike concept in supersonic flows based on conjugate heat transfer approach

    Science.gov (United States)

    Zhu, Liang; Chen, Xiong; Li, Yingkun; Musa, Omer; Zhou, Changsheng

    2018-01-01

    When flying at supersonic or hypersonic speeds through the air, the drag and severe heating have a great impact on the vehicles, thus the drag reduction and thermal protection studies have attracted worldwide attention. In the current study, the Reynolds-averaged Navier-Stokes (RANS) equations coupled with the shear stress transport (SST) k - ω turbulence model have been employed to investigate the flow behavior induced by a novel combinational lateral jet and spike concept in supersonic flows. A coupling conjugate heat transfer (CHT) approach has been applied to investigate the thermal protection, which takes the heat transfer of structure into consideration. After the code was validated by the available experimental results and the gird independency analysis was carried out, the influences of the spike length ratio, lateral jet pressure ratio and lateral jet location on the drag and heat reduction performance are analyzed comprehensively. The obtained results show that a remarkable reduction in the drag and heat flux is achieved when a lateral jet is added to the spike. This implies that the combinational lateral jet and spike concept in supersonic flows have a great benefit to the drag and heat reduction. Both the drag and heat reduction decrease with the increase of the lateral jet pressure ratio, and the heat flux is more sensitive to the lateral jet pressure ratio. The lateral jet should not be located in the bottom of the spike in order to realize better drag and heat reduction performance. The drag and heat flux could be reduced by about 45% by reasonable lateral jet location. The drag decreases with the increase of the spike length ratio whereas the heat flux is affected by the spike length ratio just in a certain range.

  7. Solving 2D/3D Heat Conduction Problems by Combining Topology Optimization and Anisotropic Mesh Adaptation

    DEFF Research Database (Denmark)

    Jensen, Kristian

    2018-01-01

    Topology optimization was recently combined with anisotropic mesh adaptation to solve 3D minimum compliance problems in a fast and robust way. This paper demonstrates that the methodology is also applicable to 2D/3D heat conduction problems. Nodal design variables are used and the objective...... function is chosen such that the problem is self-adjoint. There is no way around the book keeping associated with mesh adaptation, so the whole 5527 line MATLAB code is published (https://github.com/kristianE86/trullekrul). The design variables as well as the sensitivities have to be interpolated between...

  8. Combined Heat and Power: A Decade of Progress, A Vision for the Future

    Energy Technology Data Exchange (ETDEWEB)

    none,

    2009-08-01

    Over the past 10 years, DOE has built a solid foundation for a robust CHP marketplace. We have aligned with key partners to produce innovative technologies and spearhead market-transforming projects. Our commercialization activities and Clean Energy Regional Application Centers have expanded CHP across the nation. More must be done to tap CHP’s full potential. Read more about DOE’s CHP Program in “Combined Heat and Power: A Decade of Progress, A Vision for the Future.”

  9. Decreasing of energy consumption for space heating in existing residential buildings; Combined geothermal and gas district heating systems

    International Nuclear Information System (INIS)

    Rosca, Marcel

    2000-01-01

    The City of Oradea, Romania, has a population of about 230 000 inhabitants. Almost 70% of the total heat demand, including industrial, is supplied by a classical East European type district heating system. The heat is supplied by two low grade coal fired co-generation power plants. The oldest distribution networks and substitutions, as well as one power plant, are 35 years old and require renovation or even reconstruction. The geothermal reservoir located under the city supplies at present 2,2% of the total heat demand. By generalizing the reinjection, the production can be increased to supply about 8% of the total heat demand, without any significant reservoir pressure or temperature decline over 25 years. Another potential energy source is natural gas, a main transport pipeline running close to the city. Two possible scenarios are envisaged to replace the low grade coal by natural gas and geothermal energy as heat sources for Oradea. In one scenario, the geothermal energy supplies the heat for tap water heating and the base load for space heating in a limited number of substations, with peak load being produced by natural gas fired boilers. In the other scenario, the geothermal energy is only used for tap water heating. In both scenarios, all substations are converted into heat plants, natural gas being the main energy source. The technical, economic, and environmental assessment of the two proposed scenarios are compared with each other, as well as with the existing district heating system. Two other possible options, namely to renovate and convert the existing co-generation power plants to natural gas fired boilers or to gas turbines, are only briefly discussed, being considered unrealistic, at least for the short and medium term future. (Author)

  10. The effects of combined treatment of irradiation and heat on bacteria escherichia coli and sarcina lutea in dry condition

    International Nuclear Information System (INIS)

    Nikham; Hilmy, Nazly

    1987-01-01

    The effects of combination treatment of irradiation and heat on bacteria escherichia coli and sarcina lutea in dry condition. Investigation on the effects of combined irradiation + heat and heat + irradiation treatments have been carried out i.e. at the doses of 0; 1.0; 1.5; and 2.0 kGy with heating at 50 0 C for 10; 20; and 30 minutes on escherichia coli B/r, escherichia coli from sludge and sarcine lutea. Samples of bacteria were prepared in dry condition by using sterile fine sand as carrier. Irradiation was done in aerobic condition with RH 90% and the time range between irradiation and heating was not more than 2 hours. The results showed that the D 10 value did not give significant difference between the combined irradiation + heat, and heat + irradiation treatments for the 3 species of bacteria, compared to irradiation only (p 0.05). Doses of 1.0 and 1.5 kGy combined with heating at 50 0 C for 10 and 20 minutes gave better results compared to irradiation only. 17 refs

  11. Measurement of the combined heat and water-vapour flow through clothing under transient conditions

    Science.gov (United States)

    Farnworth, B.; Nordli, B.

    1982-03-01

    A sweating hot plate for the study of combined heat and water-vapor flow through clothing under Transient conditions is described. The results are in good agreement with the mathematical model reported in a previous paper for several model clothing systems. The heat loss through wool clothing was found to be smaller than that through similar polyester clothing during periods of sweating and larger during subsequent periods of drying, because of the effects of absorption of water vapor by hygroscopic materials. A comparison was made of the heat and vapor transmission of the clothing systems by incorporating a vapor-impermeable fabric or the waterproof but vapor-permeable fabric Gore-TEx. Liquid water was observed to condence on the inner surface of both fabrics during periods of sweating but the Gore-TEx dried within a few minutes of the end of the sweating period. Gore-TEx was found to be vapor permeable even at temperatures below 0 degrees C when frost was forming on its inner surface.

  12. Modeling combined heat transfer in an all solid state optical cryocooler

    Science.gov (United States)

    Kuzhiveli, Biju T.

    2017-12-01

    Attaining cooling effect by using laser induced anti-Stokes fluorescence in solids appears to have several advantages over conventional mechanical systems and has been the topic of recent analysis and experimental work. Using anti-Stokes fluorescence phenomenon to remove heat from a glass by pumping it with laser light, stands as a pronouncing physical basis for solid state cooling. Cryocooling by fluorescence is a feasible solution for obtaining compactness and reliability. It has a distinct niche in the family of small capacity cryocoolers and is undergoing a revolutionary advance. In pursuit of developing laser induced anti-Stokes fluorescent cryocooler, it is required to develop numerical tools that support the thermal design which could provide a thorough analysis of combined heat transfer mechanism within the cryocooler. The paper presents the details of numerical model developed for the cryocooler and the subsequent development of a computer program. The program has been used for the understanding of various heat transfer mechanisms and is being used for thermal design of components of an anti-Stokes fluorescent cryocooler.

  13. Modelling of combined ICRF and NBI heating in JET hybrid plasmas

    Directory of Open Access Journals (Sweden)

    Gallart Dani

    2017-01-01

    Full Text Available During the 2015-2016 JET campaigns many efforts have been devoted to the exploration of high performance plasma scenarios envisaged for ITER operation. In this paper we model the combined ICRF+NBI heating in selected key hybrid discharges using PION. The antenna frequency was tuned to match the cyclotron frequency of minority hydrogen (H at the center of the tokamak coinciding with the second harmonic cyclotron resonance of deuterium. The modelling takes into account the synergy between ICRF and NBI heating through the second harmonic cyclotron resonance of deuterium beam ions which allows us to assess its impact on the neutron rate RNT. We evaluate the influence of H concentration which was varied in different discharges in order to test their role in the heating performance. According to our modelling, the ICRF enhancement of RNT increases by decreasing the H concentration which increases the ICRF power absorbed by deuterons. We find that in the recent hybrid discharges this ICRF enhancement was in the range of 10-25%. Finally, we extrapolate the results to D-T and find that the best performing hybrid discharges correspond to an equivalent fusion power of ∼7.0 MW in D-T.

  14. High-Efficiency Small-Scale Combined Heat and Power Organic Binary Rankine Cycles

    Directory of Open Access Journals (Sweden)

    Costante Mario Invernizzi

    2018-04-01

    Full Text Available Small-CHP (Combined Heat and Power systems are generally considered a valuable technological option to the conventional boilers, in a technology developed context. If small-CHP systems are associated with the use of renewable energies (biomass, for example they could play an important role in distributed generation even in developing countries or, in any case, where there are no extensive electricity networks. Traditionally the considered heat engines for micro- or mini-CHP are: the gas engine, the gas turbine (with internal combustion, the steam engine, engine working according to the Stirling and to the Rankine cycles, the last with organic fluids. In principle, also fuel cells could be used. In this paper, we focus on small size Rankine cycles (10–15 k W with organic working fluids. The assumed heat source is hot combustion gases at high temperature (900–950 ∘ C and we assume to use only single stages axial turbines. The need to work at high temperatures, limits the choice of the right organic working fluids. The calculation results show the limitation in the performances of simple cycles and suggest the opportunity to resort to complex (binary cycle configurations to achieve high net conversion efficiencies (15–16%.

  15. Financial appraisal of a combined heat and power system for a hotel in Cyprus

    Energy Technology Data Exchange (ETDEWEB)

    Papamarcou, M.; Kalogirou, S. [Higher Technical Inst., Nicosia, Cyprus (Greece)

    2001-04-01

    A combined heat and power (CHP) system can convert low cost fuel, such as gas or fuel oil, into high value electricity and heat. It can generate ''home-made'' electricity more cheaply than it can be purchased. The term CHP is used to define the process of utilising the plant to generate both electricity and heat simultaneously, thereby extracting a greater benefit from the fuel used. In this work, a feasibility study of a CHP system for a hotel application is presented. The Cyprus energy scene is presented, followed by an energy analysis of the hotel. A description of the CHP system is also presented. The method of economic analysis adopted in this study is the discounted cash flow method, which takes into account the time value of money. The analysis is conducted with the use of a spreadsheet program. The economic analysis of the CHP system shows that the annual net saving of the system is around Cy 26,500 pounds, while the capital investment is Cy85,000 pounds. The payback period of the system is found to be 3.2 years, which is very satisfactory. Based on the findings presented in this paper, it is believed that CHP is viable for the Cyprus hotel industry. (author)

  16. Study on the application of combined cooling, heating and power system with biomass energy in China

    Science.gov (United States)

    Guan, Haibin; Sun, Rongfeng; Zhang, Weijie; Fan, Xiaoxu; Jiang, Jianguo; Zhao, Baofeng

    2017-08-01

    CCHP (Combined Cooling Heating and Power) system is highly evaluated and developed rapidly around the world possessing better performance than traditional energy systems because of the cascade utilization of energy. Biomass is one of the renewable energy resources that is abundant and has been widely used in China for a long time. In this paper the principle and development of biomass gasification system and CCHP is clarified, the feasibility of combining the two systems together is analyzed from theoretical and technical points of view, and the active significance is also indicated. In conclusion, it is feasible to develop CCHP with Biomass Energy in an agricultural country such as China, which can flourish in the future.

  17. A numerical study on combined forced and natural convection heat transfer in a vertical cylinder bundle

    International Nuclear Information System (INIS)

    Inoue, Ken; Hattori, Naozo

    2002-01-01

    Combined forced and natural convection in a bundle of vertical cylinders has been studied numerically by use of Riemann geometry. The cylinders heated uniformly are arranged in an equilateral triangular pattern, and three bundle spacings, s/D=1.1, 1.5 and 1.9. Numerical calculations are made of the combined convection of air (Pr=0.7) in a subchannel of the bundle at the ratios of modified Grashof number to Reynolds number Gr*/Re from 1 to 10 5 . The results show that reverse flows appear along the center line in the subchannel with increasing Gr*/Re. Local Nusselt numbers for the thermally fully-developed region are well correlated with Gr*/Re. (author)

  18. A comparison of advanced heat recovery power cycles in a combined cycle for large ships

    DEFF Research Database (Denmark)

    Larsen, Ulrik; Sigthorsson, Oskar; Haglind, Fredrik

    2014-01-01

    Strong motivation exists within the marine sector to reduce fuel expenses and to comply with ever stricter emission regulations. Heat recovery can address both of these issues. The ORC (organic Rankine cycle), the Kalina cycle and the steam Rankine cycle have received the majority of the focus...... model is combined with a turbocharger model and bottoming cycle models written in Matlab. Genetic algorithm optimisation results suggest that the Kalina cycle possess no significant advantages compared to the ORC or the steam cycle. While contributing to very high efficiencies, the organic working...... in the literature. In the present work we compare these cycles in a combined cycle application with a large marine two-stroke diesel engine. We present an evaluation of the efficiency and the environmental impact, safety concerns and practical aspects of each of the cycles. A previously validated numerical engine...

  19. Effect of nitrite on the microbiological stability of canned Vienna sausages preserved by mild heat treatment or combinations of heat and irradiation

    International Nuclear Information System (INIS)

    Farkas, J.; Zukal, E.; Incze, K.

    1973-01-01

    Keeping quality of Vienna sausages packed in No. 1/5 cans (ca 200 g) with salt brine and heat treated with F 0 values in the range of 0.25-0.55 was studied as a function of sodium nitrate addition. In uninoculated cans the heat requirement of preservation proved to be about 0.3 F 0 in the presence of 300 ppm NaNO 2 . A heat treatment of 0.55 F 0 and 200 ppm NaNO 2 resulted in higher microbiological stability of cans inoculated with 2x10 4 /tin Clostridium sporogenes spores than a heat treatment of 1.9 F 0 without nitrite addition. The effect of the combination of heat treatment of 0.35-0.55 F 0 and 0.45 Mrad of gamma irradiation was also studied with inoculated cans. The combination of irradiation plus heat resulted in a higher microbiological stability of the samples than the reversed order of the treatments, but this synergistic effect could not be proved in all experiments. The addition of 200 ppm NaNO 2 was not as effective in increasing the shelf-life of combination treated samples as with the solely heat treated ones. In a medium composed of a 50% extract of Vienna sausages (pH 6.4, asub(w) 0.96) and inoculated with 10 5 per ml Clostridium sporogenes spores 100 ppm or more NaNO 2 was required to ensure microbiological stability of samples heat treated with F 0 0.4. In the range of the permitted concentration level for canned meat products, sodium nitrite did not influence the heat resistance of Clostridium sporogenes, but inhibited the germination of the surviving spores. (F.J.)

  20. Drought stress had a predominant effect over heat stress on three tomato cultivars subjected to combined stress

    DEFF Research Database (Denmark)

    Zhou, Rong; Yu, Xiaqing; Ottosen, Carl-Otto

    2017-01-01

    of combined drought and heat stress is likely to increase. The aim of this study was to shed light on plant growth performance and leaf physiology of three tomatoes cultivars ('Arvento', 'LA1994' and 'LA2093') under control, drought, heat and combined stress. RESULTS: Shoot fresh and dry weight, leaf area...... and relative water content of all cultivars significantly decreased under drought and combined stress as compared to control. The net photosynthesis and starch content were significantly lower under drought and combined stress than control in the three cultivars. Stomata and pore length of the three cultivars...... in 'Arvento' under heat treatment. By comparison, the two heat-tolerant tomatoes were more affected by drought stress compared to 'Arvento' as shown by small stomatal and pore area, decreased sucrose content, ΦPSII (quantum yield of photosystem II), ETR (electron transport rate) and qL (fraction of open PSII...

  1. Description of innovative power technologies for biomass using. High efficiency combined production of heat, cold and electricity - ORC technologies

    International Nuclear Information System (INIS)

    Mileva, D.

    2013-01-01

    The ORC - technologies (Organic Rankine Cycle) are comfortable to be used for combined heat and power production for domestic and industrial needs (local supply), mean for their height efficiency and long exploitation period. Biomass is a primary energy source. (author)

  2. Opportunities for Combined Heat and Power at Wastewater Treatment Facilities: Market Analysis and Lessons from the Field

    Science.gov (United States)

    This report presents the opportunities for combined heat and power (CHP) applications in the municipal wastewater treatment sector, and it documents the experiences of the wastewater treatment facility (WWTF) operators who have employed CHP.

  3. Thermodynamic and economic analysis of integrating lignocellulosic bioethanol production in a Danish combined heat and power unit

    DEFF Research Database (Denmark)

    Lythcke-Jørgensen, Christoffer Ernst; Haglind, Fredrik; Clausen, Lasse Røngaard

    Integrating lignocellulosic bioethanol production with combined heat and power (CHP) production in polygeneration systems is considered an efficient and competitive way to produce a sustainable fuel for the transportation sector. This study assessed the energy economy of integrating lignocellulosic...

  4. Performance of a convective, infrared and combined infrared- convective heated conveyor-belt dryer.

    Science.gov (United States)

    El-Mesery, Hany S; Mwithiga, Gikuru

    2015-05-01

    A conveyor-belt dryer was developed using a combined infrared and hot air heating system that can be used in the drying of fruits and vegetables. The drying system having two chambers was fitted with infrared radiation heaters and through-flow hot air was provided from a convective heating system. The system was designed to operate under either infrared radiation and cold air (IR-CA) settings of 2000 W/m(2) with forced ambient air at 30 °C and air flow of 0.6 m/s or combined infrared and hot air convection (IR-HA) dryer setting with infrared intensity set at 2000 W/m(2) and hot at 60 °C being blown through the dryer at a velocity of 0.6 m/s or hot air convection (HA) at an air temperature of 60 °C and air flow velocity 0.6 m/s but without infrared heating. Apple slices dried under the different dryer settings were evaluated for quality and energy requirements. It was found that drying of apple (Golden Delicious) slices took place in the falling rate drying period and no constant rate period of drying was observed under any of the test conditions. The IR-HA setting was 57.5 and 39.1 % faster than IR-CA and HA setting, respectively. Specific energy consumption was lower and thermal efficiency was higher for the IR-HA setting when compared to both IR-CA and HA settings. The rehydration ratio, shrinkage and colour properties of apples dried under IR-HA conditions were better than for either IR-CA or HA.

  5. Passive Decay Heat Removal Strategy of Integrated Passive Safety System (IPSS) for SBO-combined Accidents

    International Nuclear Information System (INIS)

    Kim, Sang Ho; Chang, Soon Heung; Jeong, Yong Hoon

    2014-01-01

    The weak points of nuclear safety would be in outmoded nuclear power plants like the Fukushima reactors. One of the systems for the safety enhancement is integrated passive safety system (IPSS) proposed after the Fukushima accidents. It has the five functions for the prevention and mitigation of a severe accident. Passive decay heat removal (PDHR) strategy using IPSS is proposed for coping with SBO-combined accidents in this paper. The two systems for removing decay heat before core-melt were applied in the strategy. The accidents were simulated by MARS code. The reference reactor was OPR1000, specifically Ulchin-3 and 4. The accidents included loss-of-coolant accidents (LOCA) because the coolant losses could be occurred in the SBO condition. The examples were the stuck open of PSV, the abnormal open of SDV and the leakage of RCP seal water. Also, as LOCAs with the failure of active safety injection systems were considered, various LOCAs were simulated in SBO. Based on the thermal hydraulic analysis, the probabilistic safety analysis was carried out for the PDHR strategy to estimate the safety enhancement in terms of the variation of core damage frequency. AIMS-PSA developed by KAERI was used for calculating CDF of the plant. The IPSS was applied in the PDHR strategy which was developed in order to cope with the SBO-combined accidents. The estimation for initiating SGGI or PSIS was based on the pressure in RCS. The simulations for accidents showed that the decay heat could be removed for the safety duration time in SBO. The increase of safety duration time from the strategy provides the increase of time for the restoration of AC power

  6. Effect of yeast antagonist in combination with heat treatment on postharvest blue mold decay and Rhizopus decay of peaches.

    Science.gov (United States)

    Zhang, Hongyin; Wang, Lei; Zheng, Xiaodong; Dong, Ying

    2007-04-01

    The potential of using heat treatment alone or in combination with an antagonistic yeast for the control of blue mold decay and Rhizopus decay of peaches caused by Penicillium expansum and Rhizopus stolonifer respectively, and in reducing natural decay development of peach fruits, as well as its effects on postharvest quality of fruit was investigated. In vitro tests, spore germination of pathogens in PDB was greatly controlled by the heat treatment of 37 degrees C for 2 d. In vivo test to control blue mold decay of peaches, heat treatment and antagonist yeast, as stand-alone treatments, were capable of reducing the percentage of infected wounds from 92.5% to 52.5% and 62.5%, respectively, when peach fruits stored at 25 degrees C for 6 d. However, in fruit treated with combination of heat treatment and Cryptococcus laurentii, the percentage of infected wounds of blue mold decay was only 22.5%. The test of using heat treatment alone or in combination with C. laurentii to control Rhizopus decay of peaches gave a similar result. The application of heat treatment and C. laurentii resulted in low average natural decay incidences on peaches after storage at 4 degrees C for 30 days and 20 degrees C for 7 days ranging from 40% to 30%, compared with 20% in the control fruit. The combination of heat treatment and C. laurentii was the most effective treatment, and the percentage of decayed fruits was 20%. Heat treatment in combination with C. laurentii had no significant effect on firmness, TSS, ascorbic acid or titratable acidity compared to control fruit. Thus, the combination of heat treatment and C. laurentii could be an alternative to chemicals for the control of postharvest decay on peach fruits.

  7. Lifetime Assessment of Combined Cycles for Cogeneration of Power and Heat in Offshore Oil and Gas Installations

    Directory of Open Access Journals (Sweden)

    Luca Riboldi

    2017-05-01

    Full Text Available The utilization of combined cycles for offshore cogeneration of power and heat is an attractive option to reduce the CO2 emissions directly related to the oil and gas sector. Main challenges for their efficient implementation are the potentially large heat-to-power ratios and the variability of power and heat requirements throughout the different stages of a field’s lifetime. This paper aimed to provide the first elements for an assessment of the technology. Two combined cycle configurations were evaluated (backpressure and extraction steam turbine cycle, as well as different scenarios of power and heat requirements. The optimum design approach was firstly investigated. Designing the combined cycle at the end-life conditions, rather than at peak conditions, demonstrated to return better overall performance, when the entire plant’s lifetime is considered. A comparative analysis between the defined optimum designs was then carried out. Although the backpressure steam turbine cycle demonstrated to be feasible in all the cases analyzed, it showed to be effective only for offshore installations characterized by low temperature large process heat demands. On the other hand, the extraction steam turbine cycle could not meet large process heat demands but it was very attractive when the heat requirements were more limited, irrespective of the temperature at which this heat was requested.

  8. A comparison of advanced heat recovery power cycles in a combined cycle for large ships

    International Nuclear Information System (INIS)

    Larsen, Ulrik; Sigthorsson, Oskar; Haglind, Fredrik

    2014-01-01

    Strong motivation exists within the marine sector to reduce fuel expenses and to comply with ever stricter emission regulations. Heat recovery can address both of these issues. The ORC (organic Rankine cycle), the Kalina cycle and the steam Rankine cycle have received the majority of the focus in the literature. In the present work we compare these cycles in a combined cycle application with a large marine two-stroke diesel engine. We present an evaluation of the efficiency and the environmental impact, safety concerns and practical aspects of each of the cycles. A previously validated numerical engine model is combined with a turbocharger model and bottoming cycle models written in Matlab. Genetic algorithm optimisation results suggest that the Kalina cycle possess no significant advantages compared to the ORC or the steam cycle. While contributing to very high efficiencies, the organic working fluids possess high global warming potentials and hazard levels. It is concluded that the ORC has the greatest potential for increasing the fuel efficiency, and the combined cycle offers very high thermal efficiency. While being less efficient, the steam cycle has the advantages of being well proven, harmless to the environment as well as being less hazardous in comparison. - Highlights: • We compare steam, ORC (organic Rankine cycle) and Kalina cycles for waste heat recovery in marine engines. • We evaluate the efficiency and important qualitative differences. • The Kalina cycle presents no apparent advantages. • The steam cycle is well known, harmless and has a high efficiency. • The ORC has the highest efficiency but also important drawbacks

  9. Heat transfer enhancement of flow insulator by combined stainless steel fibrous and wire net porous materials

    Science.gov (United States)

    Khantikomol, P.; Polsongkram, M.; Apisitpinyo, W.; Poowadin, T.

    2018-01-01

    The present research article aims to propose the heat transfer enhancement of the flow insulator using combined fibrous and wire net stainless steel porous material. The stainless fibrous plate with porosity of 0.9292 was combined to the stainless steel wire net having pore per inch (PPI) of 16 and total thickness of 30 mm. Two models of the arranging porous plates were prepared, which were model BA and model AB. Each porous plate segment had the same thickness. The examined porous plate model have porosities of 0.8452. The porous plate was placed normal to the flow direction. The air was used as working fluid heated by 5 kW electric heater, which was controlled by the automatic temperature control. Type-K thermocouples were employed to measure the air temperatures. The temperature at front of the porous plate was varied to be 350, 450, and 550°C. The air flow rate was varied in the range of 4-12 m3/hr. The experimental result showed that the temperature drop across the porous plate and the thermal efficiency increase with the inlet temperature. The air velocity slightly affects the temperature profile inside the test section at the upstream side of the porous plate but greatly affects temperature inside the porous plate. In consideration of the arranging porous plate, placing of the stainless steel wire net at the upstream side and placing the stainless steel fibrous at downstream side (model BA) results in the highest temperature drop and the highest thermal efficiency. At Re 733 and inlet temperature 550°C for model BA at 30 mm thickness, the thermal efficiency was 50%. It was shown that the combined stainless steel fibrous and stainless steel wire net porous material could be a good flow insulator.

  10. The Calculation Methods of the Specific Fuel Rate in Combined Heat and Electricity Production

    Directory of Open Access Journals (Sweden)

    I. A. Chuchueva

    2016-01-01

    Full Text Available The paper discusses a specific fuel rate in combined heat and electricity production using CHP technology. There are two objectives for calculation of specific fuel rate: a CHP technical efficiency estimate, b increasing CHP competitiveness at electricity and district heat markets. Currently, development of a number of thermo-dynamical methods of calculation solves the first problem while to solve the second one there is a number of developed economical methods of calculation. In Russia despite a decade of the wholesale electricity market progress the CHP market offers are still tightly connected with technical efficiency rate. To estimate the technical efficiency rate is widely used the least effective thermo-dynamical method – so called “physical” method”. The paper formulates a problem statement that is the specific fuel rate calculation and reviews the most widely applied methods. The review consists of two parts: in the first the Russian methods are discussed, and in the second one the methods widely used in the countries with highly developed electricity and district heat markets. A new thermo-dynamical method to calculate the specific fuel rate is introduced, which uses the linear characteristic curves of a steam turbine. The developed method allows us to take into consideration the energy inequality of the CHP products. Another advantages of this new method are calculation simplicity and small number of input data. To compare the effectiveness of different methods were introduced comparison rules and also calculations were performed. The comparison of thermo-dynamical methods shows that the most effective methods are an exergy method and also the method that takes into consideration the reduced generation of electricity (work method. Calculation complexity and large number of input data are main disadvantages of these methods. The comparison of economical methods shows that the most effective from stated point of view are a

  11. Comparative and Combinative Study of Urban Heat island in Wuhan City with Remote Sensing and CFD Simulation

    Directory of Open Access Journals (Sweden)

    Zhuang Yu

    2008-10-01

    Full Text Available Urban heat islands are one of the most critical urban environment heat problems. Landsat ETM+ satellite data were used to investigate the land surface temperature and underlying surface indices such as NDVI and NDBI. A comparative study of the urban heat environment at different scales, times and locations was done to verify the heat island characteristics. Since remote sensing technology has limitations for dynamic flow analysis in the study of urban spaces, a CFD simulation was used to validate the improvement of the heat environment in a city by means of wind. CFD technology has its own shortcomings in parameter setting and verification, while RS technology is helpful to remedy this. The city of Wuhan and its climatological condition of being hot in summer and cold in winter were chosen to verify the comparative and combinative application of RS with CFD in studying the urban heat island.

  12. Social anthropological and interdisciplinary research on the conversion of electrically heated single family houses to heating by combined pellet-solar systems

    International Nuclear Information System (INIS)

    Henning, Annette

    2004-01-01

    The social anthropological research presented here is part of the interdisciplinary research project PESTO, which focuses on the (partial or complete) conversion of single family houses from electric heating to heating by combined pellet-solar heating systems. Basic to this research is the assumption that it is more likely that energy conversions are carried through, and that they are successful on a long-term basis, if the new products are designed to fit as well as possible into the everyday lives of people. The anthropological interest in the project can be divided into two parts; motives for or against a conversion among men and women in Swedish households, and product design and placement in (previously) electrically heated single-family houses. Literature studies and semi-structured qualitative interviews are the main methods used in the anthropological part of the project. During the next 3-year project period, these investigations will be used to support information and marketing, and to formulate recommendations for conversion practice of electrically heated single-family houses to combined pellet-solar heating. (Author)

  13. Residential Solar Combined Heat and Power Generation using Solar Thermoelectric Generation

    Science.gov (United States)

    Ohara, B.; Wagner, M.; Kunkle, C.; Watson, P.; Williams, R.; Donohoe, R.; Ugarte, K.; Wilmoth, R.; Chong, M. Zachary; Lee, H.

    2015-06-01

    Recent reports on improved efficiencies of solar thermoelectric generation (STEG) systems have generated interest in STEGs as a competitive power generation system. In this paper, the design of a combined cooling and power utilizing concentrated solar power is discussed. Solar radiation is concentrated into a receiver connected to thermoelectric modules, which are used as a topping cycle to generate power and high grade heat necessary to run an absorption chiller. Modeling of the overall system is discussed with experimental data to validate modeling results. A numerical modeling approach is presented which considers temperature variation of the source and sink temperatures and is used to maximize combined efficiency. A system is built with a demonstrated combined efficiency of 32% in actual working conditions with power generation of 3.1 W. Modeling results fell within 3% of the experimental results verifying the approach. An optimization study is performed on the mirror concentration ration and number of modules for thermal load matching and is shown to improve power generation to 26.8 W.

  14. Distributed energy resources customer adoption modeling with combined heat and power applications

    Energy Technology Data Exchange (ETDEWEB)

    Siddiqui, Afzal S.; Firestone, Ryan M.; Ghosh, Srijay; Stadler, Michael; Edwards, Jennifer L.; Marnay, Chris

    2003-07-01

    In this report, an economic model of customer adoption of distributed energy resources (DER) is developed. It covers progress on the DER project for the California Energy Commission (CEC) at Berkeley Lab during the period July 2001 through Dec 2002 in the Consortium for Electric Reliability Technology Solutions (CERTS) Distributed Energy Resources Integration (DERI) project. CERTS has developed a specific paradigm of distributed energy deployment, the CERTS Microgrid (as described in Lasseter et al. 2002). The primary goal of CERTS distributed generation research is to solve the technical problems required to make the CERTS Microgrid a viable technology, and Berkeley Lab's contribution is to direct the technical research proceeding at CERTS partner sites towards the most productive engineering problems. The work reported herein is somewhat more widely applicable, so it will be described within the context of a generic microgrid (mGrid). Current work focuses on the implementation of combined heat and power (CHP) capability. A mGrid as generically defined for this work is a semiautonomous grouping of generating sources and end-use electrical loads and heat sinks that share heat and power. Equipment is clustered and operated for the benefit of its owners. Although it can function independently of the traditional power system, or macrogrid, the mGrid is usually interconnected and exchanges energy and possibly ancillary services with the macrogrid. In contrast to the traditional centralized paradigm, the design, implementation, operation, and expansion of the mGrid is meant to optimize the overall energy system requirements of participating customers rather than the objectives and requirements of the macrogrid.

  15. Exergoeconomic performance optimization of an endoreversible intercooled regenerative Brayton combined heat and power plant coupled to variable-temperature heat reservoirs

    Energy Technology Data Exchange (ETDEWEB)

    Yang, Bo; Chen, Lingen; Sun, Fengrui [College of Naval Architecture and Power, Naval University of Engineering, Wuhan 430033 (China)

    2012-07-01

    An endoreversible intercooled regenerative Brayton combined heat and power (CHP) plant model coupled to variable-temperature heat reservoirs is established. The exergoeconomic performance of the CHP plant is investigated using finite time thermodynamics. The analytical formulae about dimensionless profit rate and exergy efficiency of the CHP plant with the heat resistance losses in the hot-, cold- and consumer-side heat exchangers, the intercooler and the regenerator are deduced. By taking the maximum profit rate as the objective, the heat conductance allocation among the five heat exchangers and the choice of intercooling pressure ratio are optimized by numerical examples, the characteristic of the optimal dimensionless profit rate versus corresponding exergy efficiency is investigated. When the optimization is performed further with respect to the total pressure ratio, a double-maximum profit rate is obtained. The effects of the design parameters on the double-maximum dimensionless profit rate and corresponding exergy efficiency, optimal total pressure ratio and optimal intercooling pressure ratio are analyzed in detail, and it is found that there exist an optimal consumer-side temperature and an optimal thermal capacitance rate matching between the working fluid and the heat reservoir, respectively, corresponding to a thrice-maximum dimensionless profit rate.

  16. Generic Combined Heat and Power (CHP Model for the Concept Phase of Energy Planning Process

    Directory of Open Access Journals (Sweden)

    Satya Gopisetty

    2016-12-01

    Full Text Available Micro gas turbines (MGTs are regarded as combined heat and power (CHP units which offer high fuel utilization and low emissions. They are applied in decentralized energy generation. To facilitate the planning process of energy systems, namely in the context of the increasing application of optimization techniques, there is a need for easy-to-parametrize component models with sufficient accuracy which allow a fast computation. In this paper, a model is proposed where the non-linear part load characteristics of the MGT are linearized by means of physical insight of the working principles of turbomachinery. Further, it is shown that the model can be parametrized by the data usually available in spec sheets. With this model a uniform description of MGTs from several manufacturers covering an electrical power range from 30 k W to 333 k W can be obtained. The MGT model was implemented by means of Modelica/Dymola. The resulting MGT system model, comprising further heat exchangers and hydraulic components, was validated using the experimental data of a 65 k W MGT from a trigeneration energy system.

  17. Combined heat and power in Dutch greenhouses: A case study of technology diffusion

    International Nuclear Information System (INIS)

    Veen, Reinier A.C. van der; Kasmire, Julia

    2015-01-01

    This paper presents a case study of the rapid diffusion of combined heat and power (CHP) units through the Dutch greenhouse horticulture sector between 2003 and 2009 in order to gain new insights regarding technology transitions. We present a sectoral diffusion analysis framework, which we apply to identify and examine developments in technical, economic, institutional, cultural and ecological domains that all contributed to an emergent and thorough CHP diffusion in the Dutch greenhouse sector. Five identified key drivers behind the CHP diffusion are the opening of the energy market in 2002, the high spark spread during the transition period, the compatibility of output of a CHP unit with greenhouse demand, the flexibility provided by heat buffers, and the cooperative and competitive greenhouse sector culture. We conclude that policies to stimulate or steer technology diffusion will benefit from an in-depth analysis of domain interactions and company decision-making processes. Such an in-depth analysis makes for well informed and targeted policies that are better able to steer an industrial sector effectively and in a socially desired direction. - Highlights: • We present a sectoral diffusion analysis framework. • We describe the case of the diffusion of cogeneration (CHP) in Dutch greenhouses. • We extract five key drivers of CHP diffusion in the Dutch greenhouse sector. • The case shows how technology diffusion emerges from co-evolutionary mechanisms. • We conclude that a co-evolutionary sectoral analysis will inform innovation policy.

  18. Stochastic Multicriteria Acceptability Analysis for Evaluation of Combined Heat and Power Units

    Directory of Open Access Journals (Sweden)

    Haichao Wang

    2014-12-01

    Full Text Available Combined heat and power (CHP is a promising technology that can contribute to energy efficiency and environmental protection. More CHP-based energy systems are planned for the future. This makes the evaluation and selection of CHP systems very important. In this paper, 16 CHP units representing different technologies are taken into account for multicriteria evaluation with respect to the end users’ requirements. These CHP technologies cover a wide range of power outputs and fuel types. They are evaluated from the energy, economy and environment (3E points of view, specifically including the criteria of efficiency, investment cost, electricity cost, heat cost, CO2 production and footprint. Uncertainties and imprecision are common both in criteria measurements and weights, therefore the stochastic multicriteria acceptability analysis (SMAA model is used in aiding this decision making problem. These uncertainties are treated better using a probability distribution function and Monte Carlo simulation in the model. Moreover, the idea of “feasible weight space (FWS” which represents the union of all preference information from decision makers (DMs is proposed. A complementary judgment matrix (CJM is introduced to determine the FWS. It can be found that the idea of FWS plus CJM is well compatible with SMAA and thus make the evaluation reliable.

  19. Regulatory Compliance and Environmental Benefit Analysis of Combined Heat and Power (CHP Systems in Taiwan

    Directory of Open Access Journals (Sweden)

    Wen-Tien Tsai

    2013-01-01

    Full Text Available The energy conservation achieved by utilizing waste heat in the energy and industrial sectors has became more and more important after the energy crisis in the 1970s because it plays a vital role in the potential energy-efficiency improvement. In this regard, cogeneration (combined heat and power, CHP systems are thus becoming attractive due to the energy, economic, and environmental policies for pursuing stable electricity supply, sustainable development and environmental pollution mitigation in Taiwan. The objective of this paper is to present an updated analysis of CHP systems in Taiwan during the period from 1990 to 2010. The description in the paper is thus based on an analysis of electricity supply/consumption and its sources from CHP systems during the past two decades, and centered on two important regulations in compliance with CHP systems (i.e., Energy Management Law and Environmental Impact Assessment Act. Based on the total net power generation from CHP systems (i.e., 35,626 GWh in 2011, it was found that the carbon dioxide reduction benefits were estimated to be around 20,000 Gg.

  20. Biomass Integrated Gasification Combined Cycle for heat and power at ethanol plants

    Energy Technology Data Exchange (ETDEWEB)

    De Kam, Matthew J.; Vance Morey, R. [Department of Bioproducts and Biosystems Engineering, University of Minnesota, 1390 Eckles Ave, St. Paul, MN 55108 (United States); Tiffany, Douglas G. [Department of Applied Economics, University of Minnesota, 1994 Buford Avenue St. Paul, MN 55108 (United States)

    2009-07-15

    Biomass Integrated Gasification Combined Cycle (BIGCC) technology can be used to generate process heat and significant amounts of electricity at dry-grind ethanol facilities by utilizing the ethanol process co-products and other biomass sources. These systems can reduce fuel costs for ethanol plants, improve the renewable energy balance of dry-grind ethanol production, and provide reliable renewable electricity for process use and for sale to the local utility. An Aspen Plus model of the dry-grind ethanol process is used as the basis for a subsequent gasification system model. A twin fluidized bed steam gasification configuration based on the SilvaGas process is used to generate synthesis gas. The results show that a dry-grind ethanol facility with a capacity of 190 million liters per year could produce 30.4 MW{sub e} of power while supplying all its process heat needs using ethanol co-products and corn cobs. This configuration results in a three fold improvement in the amount of renewable energy produced per unit of fossil energy used compared to a conventional ethanol production process using natural gas. (author)

  1. Simultaneous pasteurization and homogenization of human milk by combining heat and ultrasound: effect on milk quality.

    Science.gov (United States)

    Czank, Charles; Simmer, Karen; Hartmann, Peter E

    2010-05-01

    The combination of ultrasound and heat (thermoultrasound) is an emerging food preservation technique that retains higher quantities of bioactive components compared with current thermal pasteurization practice, but has not yet been assessed for pasteurizing human milk. Artificially contaminated human milk samples were treated with ultrasound (20 kHz, 150 watts) with and without heating. The retention of four human milk proteins was quantified by biochemical assay and laser scattering particle sizing was used to determine the extent of homogenization. While ultrasonic treatment was effective at inactivating Escherichia coli (D4 degrees C=5.94 min), Staphylococcus epidermidis exhibited resistance (D4 degrees C=16.01 min). Thermoultrasonic treatment was considerably more effective (Esch. coli D45 degrees C=1.74 min, D50 degrees C=0.89 min; Staph. epidermidis D45 degrees C=2.08 min, D50 degrees C=0.94 minutes) with a predicted retention (2.8 min treatment, 50 degrees C) of secretory IgA lysozyme, lactoferrin and bile salt stimulated lipase of 91, 80, 77, and 45%, respectively. Homogenization of the milk samples occurred after 5 min and 2 min of ultrasonic and thermoultrasonic treatment, respectively. Thermoultrasonic treatment is an effective method for pasteurizing donor human milk and retaining a greater proportion of bioactive components compared with current practices. However, further studies are required to assess the practicality of applying this technique routinely to donor human milk.

  2. Electrically heated pipe in pipe combined with electrical submersible pumps for deepwater development

    Energy Technology Data Exchange (ETDEWEB)

    Silva, Sidnei Guerreiro da; Euphemio, Mauro Luiz Lopes [PETROBRAS S.A., Rio de Janeiro, RJ (Brazil)

    2008-07-01

    The general trend of deep water and ultra deep water field development is the requirement of highly insulated flow lines, as flow assurance has become one of the major considerations in designing and operating the sub sea system. If not adequately considered in the design phase, it can have significant and unexpected effects to the operational costs, increasing production lost time, decreasing efficiency. In this scenario, the use of pipe in pipe flow lines, with high passive insulation and/ or active heating (called the Electrically Heated Pipe in Pipe - EHPIP), emerges as an attractive method to prevent deposition, especially of waxes and hydrates, by actively maintaining or leading the temperature of the flow line above a critical limit. Besides, the recent heavy oil discoveries in Brazil have encouraged PETROBRAS to move a step forward in the artificial lift design and operation, by the use of Electrical Submersible Pumps (ESP) installed in deep water wells. The combination of EHPIP and ESP are particularly suitable for deep water, high viscosity and long tie back systems, but also can improve oil recovery and production efficiency by allowing the operator to drop down production losses associated Flow Assurance problems. (author)

  3. EVALUATION OF EVACUATED TUBULAR SOLAR COLLECTORS FOR LARGE SDHW SYSTEMS AND COMBINED SPACE HEATING SYSTEMS

    DEFF Research Database (Denmark)

    Qin, Lin; Furbo, Simon

    1999-01-01

    . Based on thesemodels, the thermal performance of large solar domestic hot water (DHW) systems and combined domestichot water and space heating systems with the four evacuated tubular collectors was determined. To make acomparison with traditional flat-plate collectors, similar simulations were also......In the present study, detailed investigations on evacuated tubular solar collectors for large solarheating systems have been carried out. Four types of evacuated tubular solar collectors were used in theinvestigation. Based on laboratory tests, simulation models for the collectors were determined...... carried out for systems with atypical flat-plate collector. The results show that the thermal advantage of evacuated tubular collectors variesgreatly from system to system, and increases with the solar fraction. Furthermore, the higher the operationtemperature of the collector in the system is...

  4. Catching Fire: An Analysis of Maine's Combined Heat and Power Energy Incentive Policies

    Science.gov (United States)

    Laufer, Joshua A.

    This study qualitatively reviews and analyzes Maine's state-level incentive policies and regulations to catalyze the development of renewably fueled Combined Heat and Power (CHP) facilities by utilizing a framework developed by Janet Sawin. The results of the analysis indicate that additional opportunities exist to promote additional renewable CHP plant development through both strengthening existing state policies and passing new legislation. Maine's Renewable Portfolio Standard and Production-Based Incentive pilot program could be expanded in scope and in their level of support for renewable CHP. New policies could be enacted to further accelerate renewable CHP development in the state, such as a Production Tax Credit (PTC) and the creation of a grant program for level 2 feasibility studies within the existing Public Benefits Fund (PBF), Efficiency Maine Trust.

  5. Thermoeconomic optimization of heat recovery steam generators operating parameters for combined plants

    International Nuclear Information System (INIS)

    Casarosa, C.; Donatini, F.; Franco, A.

    2004-01-01

    The optimization of the heat recovery steam generator (HRSG) is particularly interesting for the combined plants design in order to maximise the work obtained in the vapour cycle. A detailed optimization of the HRSG is a very difficult problem, depending on several variables. The first step is represented by the optimization of the operating parameters. These are the number of pressure levels, the pressures, the mass flow ratio, and the inlet temperatures to the HRSG sections. The operating parameters can be determined by means both of a thermodynamic and of a thermoeconomic analysis, minimising a suitable objective function by analytical or numerical mathematical methods. In the paper, thermodynamic optimization is based on the minimization of exergy losses, while the thermoeconomic optimization is based on the minimization of the total HRSG cost, after the reduction to a common monetary base of the costs of exergy losses and of installation

  6. Energy and exergy analysis of a combined refrigeration and waste heat driven organic Rankine cycle system

    Directory of Open Access Journals (Sweden)

    Cihan Ertugrul

    2017-01-01

    Full Text Available Energy and exergy analysis of a combined refrigeration and waste heat driven organic Rankine cycle system were studied theoretically in this paper. In order to complete refrigeration process, the obtained kinetic energy was supplied to the compressor of the refrigeration cycle. Turbine, in power cycle, was driven by organic working fluid that exits boiler with high temperature and pressure. Theoretical performances of proposed system were evaluated employing five different organic fluids which are R123, R600, R245fa, R141b, and R600a. Moreover, the change of thermal and exergy efficiencies were examined by changing the boiling, condensing, and evaporating temperatures. As a result of energy and exergy analysis of the proposed system, most appropriate organic working fluid was determined as R141b.

  7. Feasibility analysis of fuel cells for combined heat and power systems in the tertiary sector

    Energy Technology Data Exchange (ETDEWEB)

    Zabalza, Ignacio; Aranda, Alfonso [CIRCE - Centre of Research for Energy Resources and Consumption, Polytechnic Centre, University of Zaragoza, Maria de Luna, 3, 50018 Zaragoza (Spain); Dolores de Gracia, Maria [Institute for Energy Engineering, Advanced Systems Group, Polytechnic University of Valencia, Camino de Vera s/n, 46022 Valencia (Spain)

    2007-07-15

    The aim of this paper is to present a feasibility analysis of the application of fuel cells for a combined heat and power system with grid connection in the tertiary sector. Although the analysis considers Spanish data, the methodology proposed is developed to be applicable at the EU level. The current legislative framework is analysed in order to establish the suitability of the payment scheme considered for the sale of surplus electricity from these systems. The paper also establishes criteria for the optimal design of distributed generation systems based on fuel cells from a technical, economic and environmental point of view, presenting the strategies that should be implemented to promote the future implantation of these systems and their progressive introduction to the market. (author)

  8. Effects of a shortened depreciation schedule on the investment costs for combined heat and power

    Energy Technology Data Exchange (ETDEWEB)

    Kranz, Nicole; Worrell, Ernst

    2001-11-15

    We investigate and compare several generic depreciation methods to assess the effectiveness of possible policy measures with respect to the depreciation schedules for investments in combined heat and power plants in the United States. We assess the different depreciation methods for CHP projects of various sizes (ranging from 1 MW to 100 MW). We evaluate the impact of different depreciation schedules on the tax shield, and the resulting tax savings to potential investors. We show that a shorter depreciation cycle could have a substantial impact on the cost of producing power, making cogeneration more attractive. The savings amount to approximately 6-7 percent of capital and fixed operation and maintenance costs, when changing from the current system to a 7 year depreciation scheme with switchover from declining balance to straight line depreciation. Suggestions for further research to improve the analysis are given.

  9. Micro combined heat and power operating on renewable energy for residential building

    International Nuclear Information System (INIS)

    Aoun, Bernard

    2008-01-01

    The building sector consumes more than 43% of the total national energy consumption in France leading to more than 25% of CO 2 emissions associated to this energy consumption. A large number of options exist to limit CO 2 emissions and to improve the performance of buildings. One of these options is developed in this thesis, the use of renewable energies (solar and biomass) in combined production of heat and power. Conventional systems of combined heat and power production are briefly analyzed. The major part of this work has been focused on the development of a micro-CHP system based on an organic Rankine cycle operating on renewable energies intermittent and non-intermittent (solar and wood). The working fluids have been analyzed to allow reaching high thermodynamic performance. The different promising technologies, for each components of the system are identified, depending on the working fluid. A special test bench has been designed and realized to test and characterize an oil-free vapor scroll expander suitable for our application. The different components have been sized using computerized tools developed for the modeling of the Organic Rankine cycle. A dynamic simulation tool has been developed to simulate the annual performance of the micro-CHP system operating under different climate conditions and thermal loads. Results show that the micro-CHP system could save more than 40% of the primary energy consumption and up to 60% of CO 2 emissions. The Levelized electricity cost has been calculated using economic analysis; results show that the electricity cost (50 c-euros/kWhel) is still high compared to other technologies. (author)

  10. Cob biomass supply for combined heat and power and biofuel in the north central USA

    International Nuclear Information System (INIS)

    Schmer, Marty R.; Dose, Heather L.

    2014-01-01

    Corn (Zea mays L.) cobs are being evaluated as a potential bioenergy feedstock for combined heat and power generation (CHP) and conversion into a biofuel. The objective of this study was to determine corn cob availability in north central United States (Minnesota, North Dakota, and South Dakota) using existing corn grain ethanol plants as a proxy for possible future co-located cellulosic ethanol plants. Cob production estimates averaged 6.04 Tg and 8.87 Tg using a 40 km radius area and 80 km radius area, respectively, from existing corn grain ethanol plants. The use of CHP from cobs reduces overall GHG emissions by 60%–65% from existing dry mill ethanol plants. An integrated biorefinery further reduces corn grain ethanol GHG emissions with estimated ranges from 13.9 g CO 2  equiv MJ −1 to 17.4 g CO 2  equiv MJ −1 . Significant radius area overlap (53% overlap for 40 km radius and 86% overlap for 80 km radius) exists for cob availability between current corn grain ethanol plants in this region suggesting possible cob supply constraints for a mature biofuel industry. A multi-feedstock approach will likely be required to meet multiple end user renewable energy requirements for the north central United States. Economic and feedstock logistics models need to account for possible supply constraints under a mature biofuel industry. - Highlights: • Corn cob biomass was estimated for the north central United States region. • Cobs were evaluated for combined heat and power generation and bioethanol. • Co-located ethanol plants showed a reduction in greenhouse gas emissions. • Biomass supply constraints may occur under a mature cellulosic ethanol scenario

  11. Evaluation of Combined Heat and Power (CHP Systems Using Fuzzy Shannon Entropy and Fuzzy TOPSIS

    Directory of Open Access Journals (Sweden)

    Fausto Cavallaro

    2016-06-01

    Full Text Available Combined heat and power (CHP or cogeneration can play a strategic role in addressing environmental issues and climate change. CHP systems require less fuel than separate heat and power systems in order to produce the same amount of energy saving primary energy, improving the security of the supply. Because less fuel is combusted, greenhouse gas emissions and other air pollutants are reduced. If we are to consider the CHP system as “sustainable”, we must include in its assessment not only energetic performance but also environmental and economic aspects, presenting a multicriteria issue. The purpose of the paper is to apply a fuzzy multicriteria methodology to the assessment of five CHP commercial technologies. Specifically, the combination of the fuzzy Shannon’s entropy and the fuzzy Technique for Order of Preference by Similarity to Ideal Solution (TOPSIS approach will be tested for this purpose. Shannon’s entropy concept, using interval data such as the α-cut, is a particularly suitable technique for assigning weights to criteria—it does not require a decision-making (DM to assign a weight to the criteria. To rank the proposed alternatives, a fuzzy TOPSIS method has been applied. It is based on the principle that the chosen alternative should be as close as possible to the positive ideal solution and be as far as possible from the negative ideal solution. The proposed approach provides a useful technical–scientific decision-making tool that can effectively support, in a consistent and transparent way, the assessment of various CHP technologies from a sustainable point of view.

  12. Physiological and metabolic changes of purslane (Portulaca oleracea L. in response to drought, heat and combined stresses

    Directory of Open Access Journals (Sweden)

    Rui eJin

    2016-01-01

    Full Text Available Purslane (Portulaca oleracea L. is a fleshy herbaceous plant. So far, little information is available on the response of this plant to combined drought and heat stress. In this study, changes in physiological and metabolic levels were characterized after treatments with drought, heat and combined stresses. Both individual and combined stress treatments increased malondialdehyde (MDA, electrolyte leakage (EL, O2•− and activities of superoxide dismutase (SOD, peroxidase (POD, while declined chlorophyll content. No significant differences were found between control and treatments in leaf water content (LWC and catalase (CAT activity. Additionally, 37 metabolic compounds were detected in purslane. Through pathway analysis, 17 metabolites were directly involved in the glycolysis metabolic pathway. The present study indicated that combined drought and heat stress caused more serious damage in purslane than individual stress. To survive, purslane has a high capability to cope with environmental stress conditions through activation of physiological and metabolic pathways.

  13. Physiological and Metabolic Changes of Purslane (Portulaca oleracea L.) in Response to Drought, Heat, and Combined Stresses

    Science.gov (United States)

    Jin, Rui; Wang, Yanping; Liu, Ruijie; Gou, Junbo; Chan, Zhulong

    2016-01-01

    Purslane (Portulaca oleracea L.) is a fleshy herbaceous plant. So far, little information is available on the response of this plant to combined drought and heat stress. In this study, changes in physiological and metabolic levels were characterized after treatments with drought, heat and combined stresses. Both individual and combined stress treatments increased malondialdehyde (MDA), electrolyte leakage (EL), O2•− and activities of superoxide dismutase (SOD), peroxidase (POD), while declined chlorophyll content. No significant differences were found between control and treatments in leaf water content (LWC) and catalase (CAT) activity. Additionally, 37 metabolic compounds were detected in purslane. Through pathway analysis, 17 metabolites were directly involved in the glycolysis metabolic pathway. The present study indicated that combined drought and heat stress caused more serious damage in purslane than individual stress. To survive, purslane has a high capability to cope with environmental stress conditions through activation of physiological and metabolic pathways. PMID:26779204

  14. Combined lock-in thermography and heat flow measurements for analysing heat dissipation during fatigue crack propagation

    Directory of Open Access Journals (Sweden)

    J. Bär

    2015-10-01

    Full Text Available During fatigue crack propagation experiments with constant force as well as constant stress intensity lock in thermography and heat flow measurements with a new developed peltier sensor have been performed. With lock in thermography space resolved measurements are possible and the evaluation allows to distinguish between elastic and dissipated energies. The specimens have to be coated with black paint to enhance the emissivity. The thickness of the coating influences the results and therefore quantitative measurements are problematic. The heat flow measurements are easy to perform and provide quantitative results but only integral in an area given by the used peltier element. To get comparable results the values measured with thermography were summarized in an area equivalent to that of the peltier element. The experiments with constant force show a good agreement between the thermography and the heat flow measurements. In case of the experiments with a constant stress intensity some differences become visible. Whereas the thermography measurements show a linear decrease of the signal with rising crack length, the heat flow measurements show a clearly nonlinear dependency. Obviously the measured energies in thermography and peltier based heat flow measurement are not comparable

  15. Assessment of advanced small-scale combined heat and power production

    Energy Technology Data Exchange (ETDEWEB)

    Spitzer, J. [Joanneum Research (Austria)

    1996-12-31

    To increase the share of renewable energy sources, bioenergy has to be used for electricity generation, preferably in combined heat and power (CHP) production systems, besides its traditional use in space heating. The need for small-scale, i.e. below 5 MW{sub el}, CHP production arises from the fact that a considerable portion of the available solid biofuels may not be transported over long distances for economic reasons and that in many cases the heat demand is below 10 MW{sub el} in district heating schemes in communities with less than 10 000 inhabitants. The available technical options have to be assessed with respect to performance, reliability and economy. Such an assessment has been performed in a study where the following options have been compared: Gasification - combustion engine or gas turbine; Combustion - steam turbine/engine; Combustion - hot air turbine; Combustion - Stirling engine. While conventional steam cycle systems are available and reliable they are generally not economical in the power range under consideration. Among the other systems, which are not yet commercially available, the Stirling engine system seems to be attractive in the power range below 500 kW{sub el} and the hot air system could close the gap to the steam cycle systems, i.e. cover the power range between 0.5 and 5.0 MW{sub el}. Gasification schemes seem less suitable: The power generation part (combustion engine and gas turbine) is well established for natural gas, with the combustion engine in the lower (<5 MW{sub el}) and the gas turbine in the higher (>5MW{sub el}) power range. However, the gas quality needed for the operation of a combustion engine requires expensive pre-treatment of the gas from wood gasification so that this scheme is less attractive for the power range under consideration. These conclusions lead to R and D efforts in Austria in two directions: Hot air turbine: A utility demonstration plant is under construction with a power of 1 600 kW{sub el

  16. Novel Direct Steelmaking by Combining Microwave, Electric Arc, and Exothermal Heating Technologies

    Energy Technology Data Exchange (ETDEWEB)

    Dr. Xiaodi Huang; Dr. J. Y. Hwang

    2005-03-28

    Steel is a basic material broadly used by perhaps every industry and individual. It is critical to our nation's economy and national security. Unfortunately, the American steel industry is losing competitiveness in the world steel production field. There is an urgent need to develop the next generation of steelmaking technology for the American steel industry. Direct steelmaking through the combination of microwave, electric arc, and exothermal heating is a revolutionary change from current steelmaking technology. This technology can produce molten steel directly from a shippable agglomerate, consisting of iron oxide fines, powdered coal, and ground limestone. This technology is projected to eliminate many current intermediate steelmaking steps including coking, pellet sintering, blast furnace (BF) ironmaking, and basic oxygen furnace (BOF) steelmaking. This technology has the potential to (a) save up to 45% of the energy consumed by conventional steelmaking; (b) dramatically reduce the emission of CO{sub 2}, SO{sub 2}, NO{sub x}, VOCs, fine particulates, and air toxics; (c) substantially reduce waste and emission control costs; (d) greatly lower capital cost; and (e) considerably reduce steel production costs. This technology is based on the unique capability of microwaves to rapidly heat steelmaking raw materials to elevated temperature, then rapidly reduce iron oxides to metal by volumetric heating. Microwave heating, augmented with electric arc and exothermal reactions, is capable of producing molten steel. This technology has the components necessary to establish the ''future'' domestic steel industry as a technology leader with a strong economically competitive position in world markets. The project goals were to assess the utilization of a new steelmaking technology for its potential to achieve better overall energy efficiency, minimize pollutants and wastes, lower capital and operating costs, and increase the competitiveness of the

  17. Parametric Investigation and Thermoeconomic Optimization of a Combined Cycle for Recovering the Waste Heat from Nuclear Closed Brayton Cycle

    OpenAIRE

    Lihuang Luo; Hong Gao; Chao Liu; Xiaoxiao Xu

    2016-01-01

    A combined cycle that combines AWM cycle with a nuclear closed Brayton cycle is proposed to recover the waste heat rejected from the precooler of a nuclear closed Brayton cycle in this paper. The detailed thermodynamic and economic analyses are carried out for the combined cycle. The effects of several important parameters, such as the absorber pressure, the turbine inlet pressure, the turbine inlet temperature, the ammonia mass fraction, and the ambient temperature, are investigated. The com...

  18. Energy management strategies for combined heat and electric power micro-grid

    Directory of Open Access Journals (Sweden)

    Barbarić Marina

    2016-01-01

    Full Text Available The increasing energy production from variable renewable energy sources such as wind and solar has resulted in several challenges related to the system reliability and efficiency. In order to ensure the supply-demand balance under the conditions of higher variability the micro-grid concept of active distribution networks arising as a promising one. However, to achieve all the potential benefits that micro-gird concept offer, it is important to determine optimal operating strategies for micro-grids. The present paper compares three energy management strategies, aimed at ensuring economical micro-grid operation, to find a compromise between the complexity of strategy and its efficiency. The first strategy combines optimization technique and an additional rule while the second strategy is based on the pure optimization approach. The third strategy uses model based predictive control scheme to take into account uncertainties in renewable generation and energy consumption. In order to compare the strategies with respect to cost effectiveness, a residential micro-grid comprising photovoltaic modules, thermal energy storage system, thermal loads, electrical loads as well as combined heat and power plant, is considered.

  19. Selection of optimal reheat temperature in heat recovery boiler at combined heat and power plant with GT-topping

    Directory of Open Access Journals (Sweden)

    Romashova Olga

    2017-01-01

    Full Text Available Calculations to determine optimum value of steam reheat temperature in relation to the cycle arrangement of steam turbine power plant with gas turbine topping are conducted in this paper. Operation of T-250-240 turbine unit in cogeneration mode has been considered during steam reheat displacement from steam boiler to heat recovery boiler.

  20. Optimal operation of combined heat and power system based on forecasted energy prices in real-time markets

    OpenAIRE

    Gu, Chenghong; Xie, Da; Sun, Junbo; Wang, Xitian; Ai, Qian

    2015-01-01

    This paper develops a discrete operation optimization model for combined heat and powers (CHPs) in deregulated energy markets to maximize owners' profits, where energy price forecasting is included. First, a single input and multi-output (SIMO) model for typical CHPs is established, considering the varying ratio between heat and electricity outputs at different loading levels. Then, the energy prices are forecasted with a gray forecasting model and revised in real-time based on the actual pri...

  1. Characterization of biomass producer gas as fuel for stationary gas engines in combined heat and power production

    DEFF Research Database (Denmark)

    Ahrenfeldt, Jesper

    2008-01-01

    The aim of this project has been the characterization of biomass producer gas as a fuel for stationary gas engines in heat and power production. More than 3200 hours of gas engine operation, with producer gas as fuel, has been conducted at the biomass gasification combined heat and power (CHP...... from 50% to 90% load. Biomass producer gas is an excellent lean burn engine fuel: Operation of a natural aspirated engine has been achieved for 1.2...

  2. Improving the performance of combined heat and power plants through integration with cellulosic ethanol production

    OpenAIRE

    Starfelt, Fredrik

    2011-01-01

    Today’s biomass-fired combined heat and power (CHP) plants have surplus heat production capacity during warmer times of the year. In order to allow them to increase their electricity production, it is essential to find a use for the surplus heat. Additionally, the transport sector is struggling with high fuel prices and the contribution of CO2 emissions to global warming. A promising way of reducing the negative effects caused by combustion of fossil fuels in the transport sector is to mix et...

  3. Laboratory Evaluation of Gas-Fired Tankless and Storage Water Heater Approaches to Combination Water and Space Heating

    Energy Technology Data Exchange (ETDEWEB)

    Kingston, T. [Gas Technology Inst., Des Plaines, IL (United States); Scott, S. [Gas Technology Inst., Des Plaines, IL (United States)

    2013-03-01

    Homebuilders are exploring more cost-effective combined space and water heating systems (combo systems) with major water heater manufacturers that are offering pre-engineered forced air space heating combo systems. In this project, unlike standardized tests, laboratory tests were conducted that subjected condensing tankless and storage water heater based combo systems to realistic, coincidental space and domestic hot water loads and found that the tankless combo system maintained more stable DHW and space heating temperatures than the storage combo system, among other key findings.

  4. Optimization of Combine Heat and Power Plants in the Russian Wholesale Power Market Conditions

    Directory of Open Access Journals (Sweden)

    I. A. Chuchueva

    2015-01-01

    Full Text Available The paper concerns the relevant problem to optimize the combine heat and power (CHP plants in the Russian wholesale power market conditions. Since 1975 the CHP plants specialists faced the problem of fuel rate or fuel cost reduction while ensuring the fixed level of heat and power production. The optimality criterion was the fuel rate or fuel cost which has to be minimized. Produced heat and power was paid by known tariff. Since the power market started in 2006 the power payment scheme has essentially changed: produced power is paid by market price. In such condition a new optimality criterion the paper offers is a profit which has to be maximized for the given time horizon. Depending on the optimization horizon the paper suggests four types of the problem urgency, namely: long-term, mid-term, short-term, and operative optimization. It clearly shows that the previous problem of fuel cost minimization is a special case of profit maximization problem. To bring the problem to the mixed-integer linear programming problem a new linear characteristic curves of steam and gas turbine are introduced. Error of linearization is 0.6%. The formal statement of the problem of short-term CHP plants optimization in the market conditions is offered. The problem was solved with IRM software (OpenLinkInternational for seven power plants of JSC “Quadra”: Dyagilevskaya CHP, Kurskaya CHP-1, Lipetskaya CHP-2, Orlovskaya CHP, Kurskaya CHP NWR, Tambovskaya CHP, and Smolenskaya CHP-2.The conducted computational experiment showed that a potential profit is between 1.7% and 4.7% of the fuel cost of different CHP plants and depends on the power plant operation conditions. The potential profit value is 2–3 times higher than analogous estimations, which were obtained solving fuel cost minimization problem. The perspectives of the work are formalization of mid-term and long-term CHP plants optimization problem and development of domestic software for the new problem

  5. Thermodynamic performance analysis of a combined power cycle using low grade heat source and LNG cold energy

    International Nuclear Information System (INIS)

    Kim, Kyoung Hoon; Kim, Kyung Chun

    2014-01-01

    Thermodynamic analysis of a combined cycle using a low grade heat source and LNG cold energy was carried out. The combined cycle consisted of an ammonia–water Rankine cycle with and without regeneration and a LNG Rankine cycle. A parametric study was conducted to examine the effects of the key parameters, such as ammonia mass fraction, turbine inlet pressure, condensation temperature. The effects of the ammonia mass fraction on the temperature distributions of the hot and cold streams in heat exchangers were also investigated. The characteristic diagram of the exergy efficiency and heat transfer capability was proposed to consider the system performance and expenditure of the heat exchangers simultaneously. The simulation showed that the system performance is influenced significantly by the parameters with the ammonia mass fraction having largest effect. The net work output of the ammonia–water cycle may have a peak value or increase monotonically with increasing ammonia mass fraction, which depends on turbine inlet pressure or condensation temperature. The exergy efficiency may decrease or increase or have a peak value with turbine inlet pressure depending on the ammonia mass fraction. - Highlights: • Thermodynamic analysis was performed for a combined cycle utilizing LNG cold energy. • Ammonia–water Rankine cycle and LNG Rankine cycle was combined. • A parametric study was conducted to examine the effects of the key parameters. • Characteristics of the exergy efficiency and heat transfer capability were proposed. • The system performance was influenced significantly by the ammonia mass fraction

  6. The response of previously irradiated mouse skin to heat alone or combined with irradiation: influence of thermotolerance

    International Nuclear Information System (INIS)

    Wondergem, J.; Haveman, J.

    1983-01-01

    The effect of previous x-irradiation on the response to hyperthermia (44 0 C), x-irradiation, and irradiation combined with hyperthermia (43 0 C or 44 0 C) was studied in mouse foot skin. Irradiation of mice feet 90 days before, with 20 Gy, increased the subsequent response to heat alone, or combined with irradiation, as well as to irradiation alone. It had little effect on the thermal enhancement ratios for both acute and late skin reactions. Memory of the previous irradiation treatment could be masked when the temperature of the subsequent heat treatment alone, or combined with irradiation, was 44 0 C. Priming heat treatment induced resistance to a subsequent heat treatment and to a subsequent combined irradiation-heat treatment in normal as well as previously irradiated skin. When late skin reaction was considered, a larger 'memory' of the previous irradiation treatment was always evident, compared to acute skin reaction: the 'remembered' dose in the late skin reaction was about twice the 'remembered' dose in the acute reaction. (U.K.)

  7. Combined heat and power systems: economic and policy barriers to growth

    Directory of Open Access Journals (Sweden)

    Kalam Adil

    2012-04-01

    Full Text Available Abstract Background Combined Heat and Power (CHP systems can provide a range of benefits to users with regards to efficiency, reliability, costs and environmental impact. Furthermore, increasing the amount of electricity generated by CHP systems in the United States has been identified as having significant potential for impressive economic and environmental outcomes on a national scale. Given the benefits from increasing the adoption of CHP technologies, there is value in improving our understanding of how desired increases in CHP adoption can be best achieved. These obstacles are currently understood to stem from regulatory as well as economic and technological barriers. In our research, we answer the following questions: Given the current policy and economic environment facing the CHP industry, what changes need to take place in this space in order for CHP systems to be competitive in the energy market? Methods We focus our analysis primarily on Combined Heat and Power Systems that use natural gas turbines. Our analysis takes a two-pronged approach. We first conduct a statistical analysis of the impact of state policies on increases in electricity generated from CHP system. Second, we conduct a Cost-Benefit analysis to determine in which circumstances funding incentives are necessary to make CHP technologies cost-competitive. Results Our policy analysis shows that regulatory improvements do not explain the growth in adoption of CHP technologies but hold the potential to encourage increases in electricity generated from CHP system in small-scale applications. Our Cost-Benefit analysis shows that CHP systems are only cost competitive in large-scale applications and that funding incentives would be necessary to make CHP technology cost-competitive in small-scale applications. Conclusion From the synthesis of these analyses we conclude that because large-scale applications of natural gas turbines are already cost-competitive, policy initiatives

  8. Combined heat and power systems: economic and policy barriers to growth.

    Science.gov (United States)

    Kalam, Adil; King, Abigail; Moret, Ellen; Weerasinghe, Upekha

    2012-04-23

    Combined Heat and Power (CHP) systems can provide a range of benefits to users with regards to efficiency, reliability, costs and environmental impact. Furthermore, increasing the amount of electricity generated by CHP systems in the United States has been identified as having significant potential for impressive economic and environmental outcomes on a national scale. Given the benefits from increasing the adoption of CHP technologies, there is value in improving our understanding of how desired increases in CHP adoption can be best achieved. These obstacles are currently understood to stem from regulatory as well as economic and technological barriers. In our research, we answer the following questions: Given the current policy and economic environment facing the CHP industry, what changes need to take place in this space in order for CHP systems to be competitive in the energy market? We focus our analysis primarily on Combined Heat and Power Systems that use natural gas turbines. Our analysis takes a two-pronged approach. We first conduct a statistical analysis of the impact of state policies on increases in electricity generated from CHP system. Second, we conduct a Cost-Benefit analysis to determine in which circumstances funding incentives are necessary to make CHP technologies cost-competitive. Our policy analysis shows that regulatory improvements do not explain the growth in adoption of CHP technologies but hold the potential to encourage increases in electricity generated from CHP system in small-scale applications. Our Cost-Benefit analysis shows that CHP systems are only cost competitive in large-scale applications and that funding incentives would be necessary to make CHP technology cost-competitive in small-scale applications. From the synthesis of these analyses we conclude that because large-scale applications of natural gas turbines are already cost-competitive, policy initiatives aimed at a CHP market dominated primarily by large-scale (and

  9. Heat

    CERN Document Server

    Lawrence, Ellen

    2016-01-01

    Is it possible to make heat by rubbing your hands together? Why does an ice cube melt when you hold it? In this title, students will conduct experiments to help them understand what heat is. Kids will also investigate concepts such as which materials are good at conducting heat and which are the best insulators. Using everyday items that can easily be found around the house, students will transform into scientists as they carry out step-by-step experiments to answer interesting questions. Along the way, children will pick up important scientific skills. Heat includes seven experiments with detailed, age-appropriate instructions, surprising facts and background information, a "conclusions" section to pull all the concepts in the book together, and a glossary of science words. Colorful, dynamic designs and images truly put the FUN into FUN-damental Experiments.

  10. Multi-objective optimization and exergoeconomic analysis of a combined cooling, heating and power based compressed air energy storage system

    International Nuclear Information System (INIS)

    Yao, Erren; Wang, Huanran; Wang, Ligang; Xi, Guang; Maréchal, François

    2017-01-01

    Highlights: • A novel tri-generation based compressed air energy storage system. • Trade-off between efficiency and cost to highlight the best compromise solution. • Components with largest irreversibility and potential improvements highlighted. - Abstract: Compressed air energy storage technologies can improve the supply capacity and stability of the electricity grid, particularly when fluctuating renewable energies are massively connected. While incorporating the combined cooling, heating and power systems into compressed air energy storage could achieve stable operation as well as efficient energy utilization. In this paper, a novel combined cooling, heating and power based compressed air energy storage system is proposed. The system combines a gas engine, supplemental heat exchangers and an ammonia-water absorption refrigeration system. The design trade-off between the thermodynamic and economic objectives, i.e., the overall exergy efficiency and the total specific cost of product, is investigated by an evolutionary multi-objective algorithm for the proposed combined system. It is found that, with an increase in the exergy efficiency, the total product unit cost is less affected in the beginning, while rises substantially afterwards. The best trade-off solution is selected with an overall exergy efficiency of 53.04% and a total product unit cost of 20.54 cent/kWh, respectively. The variation of decision variables with the exergy efficiency indicates that the compressor, turbine and heat exchanger preheating the inlet air of turbine are the key equipment to cost-effectively pursuit a higher exergy efficiency. It is also revealed by an exergoeconomic analysis that, for the best trade-off solution, the investment costs of the compressor and the two heat exchangers recovering compression heat and heating up compressed air for expansion should be reduced (particularly the latter), while the thermodynamic performance of the gas engine need to be improved

  11. Combined heat recovery and dry scrubbing for MWCs to meet the new EPA guidelines

    Energy Technology Data Exchange (ETDEWEB)

    Finnis, P.J. [Procedair Industries Corp., Louisville, KY (United States); Heap, B.M. [Procedair Limited, Wombourne (United Kingdom)

    1997-12-01

    Both the UK and US Municipal Waste Combuster (MWC) markets have undergone upgraded regulatory control. In the UK, the government`s Integrated Pollution Control (IPC) regime, enforced by the 1990 Environmental Protection Act (EPA) Standard IPR5/3 moved control of emissions of MWCs from local councils to the government Environmental Authority (EA). Existing MWCs had until December 1, 1996 to complete environmental upgrades. Simultaneously, the European Community (EC) was finalizing more stringent legislation to take place in the year 2001. In the US, the 1990 Clean Air Act amendments required the Environmental Protection Agency (EPA) to issue emission guidelines for new and existing facilities. Existing facilities are likely to have only until the end of 1999 to complete upgrades. In North America, Procedair Industries Corp had received contracts from Kvaerner EnviroPower AB, for APC systems of four new Refuse Derived Fuel (RDF) fluid bed boilers that incorporated low outlet temperature economizers as part of the original boiler equipment. The Fayetteville, North Carolina facility was designed for 200,000 tpy. What all these facilities have in common is low economizer outlet temperatures of 285{degrees}F coupled with a Total Dry Scrubbing System. MWC or RDF facilities using conventional spray dryer/fabric filter combinations have to have economizer gas outlet temperatures about 430{degrees}F to allow for evaporation of the lime slurry in the spray dryer without the likelihood of wall build up or moisture carry over. Since the Totally Dry Scrubbing System can operate with economizer gas outlet temperatures about 285{degrees}F, the added energy available for sale from adding low outlet temperature economizer heat recovery can be considerable. This paper focuses on Procedair`s new plant and retrofit experience using `Dry Venturi Reactor/Fabric Filter` combinations with the lower inlet temperature operating conditions.

  12. Technical Analysis of Installed Micro-Combined Heat and Power Fuel-Cell System

    Energy Technology Data Exchange (ETDEWEB)

    Brooks, Kriston P.; Makhmalbaf, Atefe

    2014-10-31

    Combined heat and power fuel cell systems (CHP-FCSs) provide consistent electrical power and hot water with greater efficiency and lower emissions than alternative sources. These systems can be used either as baseload, grid-connected, or as off-the-grid power sources. This report presents a technical analysis of 5 kWe CHP-FCSs installed in different locations in the U.S. At some sites as many as five 5 kWe system is used to provide up to 25kWe of power. Systems in this power range are considered “micro”-CHP-FCS. To better assess performance of micro-CHP-FCS and understand their benefits, the U.S. Department of Energy worked with ClearEdge Power to install fifteen 5-kWe PBI high temperature PEM fuel cells (CE5 models) in the commercial markets of California and Oregon. Pacific Northwest National Laboratory evaluated these systems in terms of their economics, operations, and technical performance. These units were monitored from September 2011 until June 2013. During this time, about 190,000 hours of data were collected and more than 17 billion data points were analyzed. Beginning in July 2013, ten of these systems were gradually replaced with ungraded systems (M5 models) containing phosphoric acid fuel cell technology. The new units were monitored until June 2014 until they went offline because ClearEdge was bought by Doosan at the time and the new manufacturer did not continue to support data collection and maintenance of these units. During these two phases, data was collected at once per second and data analysis techniques were applied to understand behavior of these systems. The results of this analysis indicate that systems installed in the second phase of this demonstration performed much better in terms of availability, consistency in generation, and reliability. The average net electrical power output increased from 4.1 to 4.9 kWe, net heat recovery from 4.7 to 5.4 kWth, and system availability improved from 94% to 95%. The average net system electric

  13. Transient Stability Improvement for Combined Heat and Power System Using Load Shedding

    Directory of Open Access Journals (Sweden)

    Hung-Cheng Chen

    2014-01-01

    Full Text Available The purpose of the paper is to analyze and improve the transient stability of an industrial combined heat and power (CHP system in a high-tech science park in Taiwan. The CHP system installed two 161 kV/161 kV high-impendence transformers to connect with Taipower System (TPS for both decreasing the short-circuit fault current and increasing the fault critical clearing time. The transient stabilities of three types of operation modes in CHP units, 3G1S, 2G1S, and 1G1S, are analyzed. Under the 3G1S operation mode, the system frequency is immediately restored to 60 Hz after tie line tripping with the TPS. Under the 1G1S and 2G1S operation modes, the system frequencies will continuously decrease and eventually become unstable. A novel transient stability improvement approach using load shedding technique based on the change in frequency is proposed to improve the transient stability.

  14. Analysis and sizing of thermal energy storage in combined heating, cooling and power plants for buildings

    International Nuclear Information System (INIS)

    Martínez-Lera, S.; Ballester, J.; Martínez-Lera, J.

    2013-01-01

    Highlights: ► Novel method to estimate the contribution of thermal energy storage in CHCP plants. ► Simple and accurate analysis of contributions of thermal storage. ► Application to the assessment and optimal sizing of thermal storage in CHCP plants. ► Thermal storage increases efficiency, coverage and economic benefit. ► Thermal storage allows increasing efficient operation of the plant. - Abstract: Thermal energy storage (TES) can lead to significant energy savings and economic benefits in combined heating, cooling and power plants (CHCPs) for buildings in the tertiary sector. However, their complex interactions with the rest of the CHCP system make their adequate sizing difficult without using extensive and detailed simulations. The authors have developed a new method to evaluate the thermal contribution of TES based on simple procedures. Comparisons with detailed simulations for a range of situations confirm the ability of this method to predict the effect of TES on CHCP systems with good approximation, as well as to find the optimal size in a relatively simple manner and with few required data. The case studies show a strong dependence of the TES contribution on the demands profile and the operation strategy. However, adequately sized TES are proven to bring relevant energy savings as well as economic profit to CHCP plants. In this paper, sizing procedures are provided to find the optimal volume both in terms of thermodynamic efficiency and of economic profit

  15. Verification of combined thermal-hydraulic and heat conduction analysis code FLOWNET/TRUMP

    International Nuclear Information System (INIS)

    Maruyama, Soh; Fujimoto, Nozomu; Sudo, Yukio; Kiso, Yoshihiro; Murakami, Tomoyuki.

    1988-09-01

    This report presents the verification results of the combined thermal-hydraulic and heat conduction analysis code, FLOWNET/TRUMP which has been utilized for the core thermal hydraulic design, especially for the analysis of flow distribution among fuel block coolant channels, the determination of thermal boundary conditions for fuel block stress analysis and the estimation of fuel temperature in the case of fuel block coolant channel blockage accident in the design of the High Temperature Engineering Test Reactor(HTTR), which the Japan Atomic Energy Research Institute has been planning to construct in order to establish basic technologies for future advanced very high temperature gas-cooled reactors and to be served as an irradiation test reactor for promotion of innovative high temperature new frontier technologies. The verification of the code was done through the comparison between the analytical results and experimental results of the Helium Engineering Demonstration Loop Multi-channel Test Section(HENDEL T 1-M ) with simulated fuel rods and fuel blocks. (author)

  16. Verification of combined thermal-hydraulic and heat conduction analysis code FLOWNET/TRUMP

    Science.gov (United States)

    Maruyama, Soh; Fujimoto, Nozomu; Kiso, Yoshihiro; Murakami, Tomoyuki; Sudo, Yukio

    1988-09-01

    This report presents the verification results of the combined thermal-hydraulic and heat conduction analysis code, FLOWNET/TRUMP which has been utilized for the core thermal hydraulic design, especially for the analysis of flow distribution among fuel block coolant channels, the determination of thermal boundary conditions for fuel block stress analysis and the estimation of fuel temperature in the case of fuel block coolant channel blockage accident in the design of the High Temperature Engineering Test Reactor(HTTR), which the Japan Atomic Energy Research Institute has been planning to construct in order to establish basic technologies for future advanced very high temperature gas-cooled reactors and to be served as an irradiation test reactor for promotion of innovative high temperature new frontier technologies. The verification of the code was done through the comparison between the analytical results and experimental results of the Helium Engineering Demonstration Loop Multi-channel Test Section(HENDEL T(sub 1-M)) with simulated fuel rods and fuel blocks.

  17. Combined heating and chemical treatment for oil recovery from aging crude oil.

    Science.gov (United States)

    Hou, Chunjuan; Jiang, Qingzhe; Song, Zhaozheng; Tan, Guorong; Shi, Zhan

    2016-07-01

    With increasing use of chemical oil displacement agents in tertiary recovery and the application of various demulsifiers for crude oil dehydration, a large amount of aging crude oil containing a high ratio of water is produced, and it is very difficult for processing and utilisation. In this article, we chose aging crude oil samples from a union station in an oilfield in China. Sample composition was analysed to demonstrate that the key of aging crude oil dehydration is the removal of solid impurities. Thus, an efficient method of combining heating and chemical treatments was developed to treat aging crude oil. It includes two steps: The first step is washing of aging crude oil with hot water with sodium dodecylbenzene sulfonate; the second step is chemical demulsification of the above mixture with hydrochloric acid and sodium chloride solution. The result showed that 2.9% of solid impurities and 29.2% of water were removed in the first step; 27.2% of oil, 24.3% of water, and 3.47% of solid impurities in the aging crude oil were recycled in the second step. A total 87.07% of aging crude oil could be solved with this method. The present two-step treatment method can ensure that the dehydration process runs normally and efficiently in the union station, making it a promising method in the recycling of aging crude oil. © The Author(s) 2016.

  18. Numerical optimization of Combined Heat and Power Organic Rankine Cycles – Part A: Design optimization

    International Nuclear Information System (INIS)

    Martelli, Emanuele; Capra, Federico; Consonni, Stefano

    2015-01-01

    This two-part paper proposes an approach based on state-of-the-art numerical optimization methods for simultaneously determining the most profitable design and part-load operation of Combined Heat and Power Organic Rankine Cycles. Compared to the usual design practice, the important advantages of the proposed approach are (i) to consider the part-load performance of the ORC at the design stage, (ii) to optimize not only the cycle variables, but also the main turbine design variables (number of stages, stage loads, rotational speed). In this first part (Part A), the design model and the optimization algorithm are presented and tested on a real-world test case. PGS-COM, a recently proposed hybrid derivative-free algorithm, allows to efficiently tackle the challenging non-smooth black-box problem. - Highlights: • Algorithm for the simultaneous optimization Organic Rakine Cycle and turbine. • Thermodynamic and economic models of boiler, cycle, turbine are developed. • Non-smooth black-box optimization problem is successfully tackled with PGS-COM. • Test cases show that the algorithm returns optimal solutions within 4 min. • Toluene outperforms MDM (a siloxane) in terms of efficiency and costs.

  19. Combined effect of heat treatment and humidity on total polyphenol content of tartary buckwheat wholeflour

    Directory of Open Access Journals (Sweden)

    Andrea BRUNORI

    2016-12-01

    Full Text Available Minor crops are gaining new interest due to the high content of bioactive compounds available in their grain and the consequent opportunity to be employed as ingredients for the production of healthy foodstuff. Tartary buckwheat (Fagopyrum tataricum Gaertn. grain is rich in flavonoids, the most important being represented by rutin, a compound possessing a high health value. When processing bakery products added with Tartary buckwheat whole flour, the key point is to prevent rutin from being hydrolysed to quercetin. In this view, a combination of heat treatment and controlled humidity level was applied for different lengths of time, in the attempt to deactivate the enzymes catalysing the reaction. Tartary buckwheat grain contains other polyphenols also capable to confer health properties. This class of compounds has been associated with the prevention of cardiovascular diseases, cancers, neurodegenerative diseases, diabetes, and osteoporosis. In this study it was observed how the physical treatments meant to preserve rutin would influence the overall content of polyphenols in Tartary buckwheat whole flour and dough.

  20. Placement of Combined Heat, Power and Hydrogen Production Fuel Cell Power Plants in a Distribution Network

    Directory of Open Access Journals (Sweden)

    Bahman Bahmanifirouzi

    2012-03-01

    Full Text Available This paper presents a new Fuzzy Adaptive Modified Particle Swarm Optimization algorithm (FAMPSO for the placement of Fuel Cell Power Plants (FCPPs in distribution systems. FCPPs, as Distributed Generation (DG units, can be considered as Combined sources of Heat, Power, and Hydrogen (CHPH. CHPH operation of FCPPs can improve overall system efficiency, as well as produce hydrogen which can be stored for the future use of FCPPs or can be sold for profit. The objective functions investigated are minimizing the operating costs of electrical energy generation of distribution substations and FCPPs, minimizing the voltage deviation and minimizing the total emission. In this regard, this paper just considers the placement of CHPH FCPPs while investment cost of devices is not considered. Considering the fact that the objectives are different, non-commensurable and nonlinear, it is difficult to solve the problem using conventional approaches that may optimize a single objective. Moreover, the placement of FCPPs in distribution systems is a mixed integer problem. Therefore, this paper uses the FAMPSO algorithm to overcome these problems. For solving the proposed multi-objective problem, this paper utilizes the Pareto Optimality idea to obtain a set of solution in the multi-objective problem instead of only one. Also, a fuzzy system is used to tune parameters of FAMPSO algorithm such as inertia weight. The efficacy of the proposed approach is validated on a 69-bus distribution system.

  1. Micro Combined Heat and Power to provide heat and electrical power using biomass and Gamma-type Stirling engine

    International Nuclear Information System (INIS)

    Damirchi, Hojjatollah; Najafi, G.; Alizadehnia, Siamak; Mamat, R.; Nor Azwadi, Che Sidik; Azmi, W.H.; Noor, M.M.

    2016-01-01

    Highlights: • MCHP system by using of biomass and Stirling engine produced heat and electrical power. • Thermal efficiency of Stirling engine driven by the different biomass gases was 16%. • Maximum power (25.79 W) was obtained from sawdust and minimum for wood (10.71 W). • The maximum power was obtained with helium at 550 °C and 10 bar pressure at 700 rpm. • Results encouraged initiating the design of 1 kWe MCHP for rural electrification. - Abstract: With consideration of the biomass energy potential, a Gamma type Stirling engine with 220 cc swept volume and 580 cc total volume was designed, optimized and manufactured. The engine was tested with helium. Working characteristics of the engine were obtained within the range of heat source temperature of 370–410 °C and charge pressure of 10 bar for biomass resources. The heat source temperature of 540–560 °C and range of charge pressure 1–12 bar with 1 bar increments at each stage for gases were also looked into. By using of thermodynamic and heat transfer design methods, the key parameters of the designed Stirling engine like required surfaces for heat transfer were calculated (hot side 307 and the cold side 243 squares of centimeters). For the purpose of the analysis of fluid flow, a two-dimensional flow analysis method was performed with the CFD software methods. The principles of thermodynamics as well as the Schmidt theory were adapted to use for modeling the engine and then pressure – volume diagrams of the thermodynamic and Schmidt analysis were compared. During the test, the temperature was monitored by thermocouples and the pressure of the working fluid helium was monitored by pressure sensors. Indicated power, friction power and brake power were measured and the maximum brake power output was obtained with helium at 550 °C heat source temperature and 10-bar charge pressure at 700 rpm as 96.7 W. The electrical energy was produced from burning of biomass and flammable agricultural wastes

  2. Optimal Energy Management of Combined Cooling, Heat and Power in Different Demand Type Buildings Considering Seasonal Demand Variations

    Directory of Open Access Journals (Sweden)

    Akhtar Hussain

    2017-06-01

    Full Text Available In this paper, an optimal energy management strategy for a cooperative multi-microgrid system with combined cooling, heat and power (CCHP is proposed and has been verified for a test case of building microgrids (BMGs. Three different demand types of buildings are considered and the BMGs are assumed to be equipped with their own combined heat and power (CHP generators. In addition, the BMGs are also connected to an external energy network (EEN, which contains a large CHP, an adsorption chiller (ADC, a thermal storage tank, and an electric heat pump (EHP. By trading the excess electricity and heat energy with the utility grid and EEN, each BMG can fulfill its energy demands. Seasonal energy demand variations have been evaluated by selecting a representative day for the two extreme seasons (summer and winter of the year, among the real profiles of year-round data on electricity, heating, and cooling usage of all the three selected buildings. Especially, the thermal energy management aspect is emphasized where, bi-lateral heat trading between the energy supplier and the consumers, so-called energy prosumer concept, has been realized. An optimization model based on mixed integer linear programming has been developed for minimizing the daily operation cost of the EEN while fulfilling the energy demands of the BMGs. Simulation results have demonstrated the effectiveness of the proposed strategy.

  3. Energy Optimization for Transcritical CO2 Heat Pump for Combined Heating and Cooling and Thermal Storage Applications

    DEFF Research Database (Denmark)

    Do Carmo, Carolina Madeira Ramos; Blarke, Morten; Yazawa, Kazuaki

    2012-01-01

    and cold thermal storages know as Thermal Battery (TB) (Blarke, 2012). Smart and effective use of intermittent renewable energy resources (for example solar and wind power) is obtained supplying water heating (>70 oC) and cooling services (... hypothesis is that if electricity generated by intermittent sources is destined for thermal end-uses an efficient conversion of electricity to thermal energy and storage enables a flexible power supply. Thermal storage is more cost-effective than any electro-chemical or mechanical storage technology...

  4. Inactivation of Nondesiccated and Desiccated Cronobacter sakazakii in Reconstituted Infant Formula by Combination of Citral and Mild Heat.

    Science.gov (United States)

    Shi, Chao; Jia, Zhenyu; Sun, Yi; Chen, Yifei; Guo, Du; Liu, Zhiyuan; Wen, Qiwu; Guo, Xiao; Ma, Linlin; Yang, Baowei; Baloch, Allah Bux; Xia, Xiaodong

    2017-07-01

    The objective of this study was to evaluate the combined effect of citral plus mild heat on nondesiccated and desiccated Cronobacter sakazakii in reconstituted infant formula. Various concentrations of citral (0, 0.3, 0.6, and 0.9%) combined with various temperatures (25, 45, 50, and 55°C) were applied to nondesiccated and desiccated cocktails of three C. sakazakii strains (approximately 6.0 log CFU mL -1 ) in reconstituted infant formula, and the bacterial populations were assayed periodically. The combined treatments had marked antimicrobial effects on C. sakazakii compared with the control. Desiccated cells were more susceptible to citral than were nondesiccated cells in reconstituted infant formula. These findings suggest there is a potential application of citral in combination with mild heat to control C. sakazakii during preparation of reconstituted infant formula.

  5. An experimental investigation of heat transfer enhancement in minichannel: Combination of nanofluid and micro fin structure techniques

    DEFF Research Database (Denmark)

    Zhang, Ji; Diao, Yanhua; Zhao, Yaohua

    2017-01-01

    This work experimentally studied the single-phase heat transfer and pressure drop characteristics by using two heat transfer enhancement techniques (micro fin structure and nanofluids) in multiport minichannel flat tube (MMFT). MMFT consisted of numerous parallel rectangular minichannels and is w......This work experimentally studied the single-phase heat transfer and pressure drop characteristics by using two heat transfer enhancement techniques (micro fin structure and nanofluids) in multiport minichannel flat tube (MMFT). MMFT consisted of numerous parallel rectangular minichannels...... with different micro fin numbers (N = 0, 1, 2, 3 and 4) and nanofluids with three volume concentrations (φ = 0.005%, 0.01% and 0.1%) were used as test sections and working fluids respectively. Secondly, the experiments using two combined enhancement technique were performed. By using conjunctively two...

  6. Integrated application of combined cooling, heating and power poly-generation PV radiant panel system of zero energy buildings

    Science.gov (United States)

    Yin, Baoquan

    2018-02-01

    A new type of combined cooling, heating and power of photovoltaic radiant panel (PV/R) module was proposed, and applied in the zero energy buildings in this paper. The energy system of this building is composed of PV/R module, low temperature difference terminal, energy storage, multi-source heat pump, energy balance control system. Radiant panel is attached on the backside of the PV module for cooling the PV, which is called PV/R module. During the daytime, the PV module was cooled down with the radiant panel, as the temperature coefficient influence, the power efficiency was increased by 8% to 14%, the radiant panel solar heat collecting efficiency was about 45%. Through the nocturnal radiant cooling, the PV/R cooling capacity could be 50 W/m2. For the multifunction energy device, the system shows the versatility during the heating, cooling and power used of building utilization all year round.

  7. The combined effect of heat and gamma irradiation on the inactivation of selected microorganisms associated with food hygiene

    International Nuclear Information System (INIS)

    Kwon, O.J.; Byun, M.W.

    1996-01-01

    The bactericidal effectiveness of radiation alone or in combination with heat against 8 strains associated with food hygiene were evaluated. In the case of radiation alone, D values of micro-organisms were 0.14~0.48 kGy, and inactivation factors were 4.54~21.43 at the doses of 2~3 kGy. Escherichia coli was the most sensitive among the tested strains, resulting in a D value of 0.14 kGy. D values of tile strains were 10~40 minutes at 50±1°C and 5~10 minutes at 60±1°C. Combination with heat and radiation showed D values of 0.04~0.31. Inactivation factors were 6.45~75 at the doses of 2 to 3 kGy. Therefore, heat treatment prior to irradiation significantly increased activation rate by increasing radiation sensitivity of microorganisms

  8. Temperature sensitive liposomes combined with thermal ablation: Effects of duration and timing of heating in mathematical models and in vivo.

    Directory of Open Access Journals (Sweden)

    Christian Rossmann

    Full Text Available Temperature sensitive liposomes (TSL are nanoparticles that rapidly release the contained drug at hyperthermic temperatures, typically above ~40°C. TSL have been combined with various heating modalities, but there is no consensus on required hyperthermia duration or ideal timing of heating relative to TSL administration. The goal of this study was to determine changes in drug uptake when heating duration and timing are varied when combining TSL with radiofrequency ablation (RF heating.We used computer models to simulate both RF tissue heating and TSL drug delivery, to calculate spatial drug concentration maps. We simulated heating for 5, 12 and 30 min for a single RF electrode, as well as three sequential 12 min ablations for 3 electrodes placed in a triangular array. To support simulation results, we performed porcine in vivo studies in normal liver, where TSL filled with doxorubicin (TSL-Dox at a dose of 30 mg was infused over 30 min. Following infusion, RF heating was performed in separate liver locations for either 5 min (n = 2 or 12 min (n = 2. After ablation, the animal was euthanized, and liver extracted and frozen. Liver samples were cut orthogonal to the electrode axis, and fluorescence imaging was used to visualize tissue doxorubicin distribution.Both in vivo studies and computer models demonstrate a ring-shaped drug deposition within ~1 cm of the visibly coagulated tissue. Drug uptake directly correlated with heating duration. In computer simulations, drug concentration increased by a factor of 2.2x and 4.3x when heating duration was extended from 5 to either 12, or 30 minutes, respectively. In vivo, drug concentration was by a factor of 2.4x higher at 12 vs 5 min heating duration (7.1 μg/g to 3.0 μg/g. The computer models suggest that heating should be timed to maximize area under the curve of systemic plasma concentration of encapsulated drug.Both computer models and in vivo study demonstrate that tissue drug uptake directly

  9. Enhancing methane production from waste activated sludge using combined free nitrous acid and heat pre-treatment.

    Science.gov (United States)

    Wang, Qilin; Jiang, Guangming; Ye, Liu; Yuan, Zhiguo

    2014-10-15

    Methane production from anaerobic digestion of waste activated sludge (WAS) is often limited by the slow degradation and poor substrate availability of WAS. Our previous study revealed that WAS pre-treatment using free nitrous acid (FNA, i.e. HNO2) is an economically feasible and environmentally friendly method for promoting methane production. In order to further improve methane production from WAS, this study presents a novel strategy based on combined FNA and heat pre-treatment. WAS from a full-scale plant was treated for 24 h with FNA alone (0.52-1.43 mg N/L at 25 °C), heat alone (35, 55 and 70 °C), and FNA (0.52-1.11 mg N/L) combined with heat (35, 55 and 70 °C). The pre-treated WAS was then used for biochemical methane potential tests. Compared to the control (no FNA or heat pre-treatment of WAS), biochemical methane potential of the pre-treated WAS was increased by 12-16%, 0-6%, 17-26%, respectively; hydrolysis rate was improved by 15-25%, 10-25%, 20-25%, respectively, for the three types of pre-treatment. Heat pre-treatment at 55 and 70 °C, independent of the presence or absence of FNA, achieved approximately 4.5 log inactivation of pathogens (in comparison to ∼1 log inactivation with FNA treatment alone), thus capable of producing Class A biosolids. The combined FNA and heat pre-treatment is an economically and environmentally attractive technology for the pre-treatment of WAS prior to anaerobic digestion, particularly considering that both FNA and heat can be produced as by-products of anaerobic sludge digestion. Copyright © 2014 Elsevier Ltd. All rights reserved.

  10. Hot water tank for use with a combination of solar energy and heat-pump desuperheating

    Science.gov (United States)

    Andrews, John W.

    1983-06-28

    A water heater or system which includes a hot water tank having disposed therein a movable baffle to function as a barrier between the incoming volume of cold water entering the tank and the volume of heated water entering the tank which is heated by the circulation of the cold water through a solar collector and/or a desuperheater of a heat pump so as to optimize the manner in which heat is imparted to the water in accordance to the demand on the water heater or system. A supplemental heater is also provided and it is connected so as to supplement the heating of the water in the event that the solar collector and/or desuperheater cannot impart all of the desired heat input into the water.

  11. Initial Development of a Combined PCM and TABS Solution for Heat Storage and Cooling

    DEFF Research Database (Denmark)

    Pomianowski, Michal Zbigniew; Heiselberg, Per; Jensen, Rasmus Lund

    2011-01-01

    This paper investigates heat storage and cooling concept that utilizes both phase change material (PCM) and a thermal active building system (TABS) implemented in a hollow core concrete deck element. PCMs are promising materials for improving the heat storage capacity of a building due...... to their significant thermal energy storage capabilities. The TABS has a potential for increasing the exploitation of the thermal mass of the building, which is rarely exposed for heat transfer.The main objective of this study is to optimize the location and amount of PCM in a hollow core deck in order to optimize...... heat storage capacity. A series of simulations were conducted using the COMSOL program to obtain knowledge regarding the dynamic heat storage capacity of the investigated hollow core deck element as a function of the amount and location of PCM. Furthermore, the dynamic heat storage capacity...

  12. 1?10 kW Stationary Combined Heat and Power Systems Status and Technical Potential: Independent Review

    Energy Technology Data Exchange (ETDEWEB)

    Maru, H. C.; Singhal, S. C.; Stone, C.; Wheeler, D.

    2010-11-01

    This independent review examines the status and technical potential of 1-10 kW stationary combined heat and power fuel cell systems and analyzes the achievability of the DOE cost, efficiency, and durability targets for 2012, 2015, and 2020.

  13. Recovery of flue gas energy in heat-integrated gasification combined cycle (IGCC) power plants using the contact economizer system

    CSIR Research Space (South Africa)

    Madzivhandila, VA

    2011-03-01

    Full Text Available (flue gas) stream of a heat-integrated gasification combined cycle (IGCC) design of the Elcogas plant adopted from previous studies. The underlying support for this idea was the direct relationship between efficiency of the IGCC and the boiler feedwater...

  14. Critical factors for profitable combined production of heat, power and biofuels; Kritiska faktorer foer loensam produktion i bioenergikombinat

    Energy Technology Data Exchange (ETDEWEB)

    Nohlgren, Ingrid; Gunnarsson, Emma; Lundqvist, Per; Stigander, Haakan; Widmark, Annika (AaF, Stockholm (Sweden))

    2012-02-15

    During the last 5-10 years, research and development efforts have been made in the field of polygeneration of heat and power with production of 'other green' products such as transport fuels or wood pellets. The driving force for heat and power producers is the potential of increased profitability through additional sales of heat. The driving force for wood pellet and some transport fuel producers is the potential of low cost process steam or heat. However, in the case of gasification based transport fuel production processes the situation is different. The process generates a surplus of heat, which can benefit from the proximity of a district heating net. In addition, some polygeneration combinations could provide other advantages such as more efficient raw material handling. Together with these driving forces, the EU renewable energy directive (which targets 10 % renewable energy use in the transport sector by 2020), shows that the market for production of renewable transport fuel is expanding. To refine Swedish biomass resources to more highly valuable products such as wood pellets or renewable transport fuels would maintain industry and employment opportunities within Sweden and at the same time fulfils the international and national climate targets. The overall aim with this project is to describe the factors which are crucial for the opportunity for profitable polygeneration of heat, power and wood pellets or renewable transport fuels and how these factors influence the location of such a plant within Sweden. The important factors can be categorized as: (1) Supply of raw material, (2) distribution of raw material and products, (3) Demand of products and (4) Integration between the different plants. In this project, only general aspects are described and should be seen as guidance for the industry (both energy and forest industry) which has an interest in polygeneration. The project gives an overview of different possibilities, opportunities and

  15. An effective method for skin blood flow measurement using local heat combined with electrical stimulation.

    Science.gov (United States)

    Almalty, A-M R; Petrofsky, J S; Al-Naami, B; Al-Nabulsi, J

    2009-01-01

    Electrical stimulation (ES) is a modality used to increase skin blood flow (SBF) and to aid in wound healing. A greater SBF in non wounded skin is induced if ES is used in a warm environment compared to a thermoneutral environment, where ES is usually applied. Therefore, in this paper, a method to investigate the effect of local heating and ES on the SBF is developed. A total of 33 males (18-40 years) were divided into group G (n = 15) who received the ES during a global heating protocol and group L (n = 18) who received ES during a local heating protocol. In the global heating protocol, ES (30 Hz, 250 micros) was applied for 15 min on the subject's thigh in thermoneutral (25 +/- 0.5 degrees C) and warm (35 +/- 0.5 degrees C) environments. In the local heating protocol, ES was applied for 15 minutes at 25 degrees C, 35 degrees C and 40 degrees C local skin temperatures. A laser Doppler imager measured the SBF in both protocols pre, during, and post ES. The results of the experiment showed the significant differences in the SBFs were found at pre, during, and post ES in a thermoneutral environment or when the skin was locally cooled to 25 degrees C. The SBFs were significantly increased during and post ES after global heating or during local heating at 35 degrees C and 40 degrees C. There were no significant differences in SBFs between the warm environment and at 35 degrees C of local heating. However, the SBF response to ES was the highest at 40 degrees C of local heating. Thus, ES during local heating of the skin, as well as during global heating is an effective method to increase SBF.

  16. Current price guided use of combined cycle power plants with heat extraction using the example of the combined cycle Tiefstack

    International Nuclear Information System (INIS)

    Sieck, Jan; Hagen, Ralf

    2015-01-01

    The sale of electricity at the European Power Exchange in the DayAhead auction contains a certain economic risk, if the electricity is produced with gas fired CHP plants. This risk is due to a low price level connected with a relatively high price volatility. An auction strategy, using block orders, including the use of smart blocks is a possible way to minimize economic risk. Such a strategy is presented in this paper, using the example of the auction strategy for the CCGT Tiefstack. As the CCGT Tiefstack is part of the district heating system of the city Hamburg, this system is described as well as the technical constraints of the CCGT.

  17. Parametric Investigation and Thermoeconomic Optimization of a Combined Cycle for Recovering the Waste Heat from Nuclear Closed Brayton Cycle

    Directory of Open Access Journals (Sweden)

    Lihuang Luo

    2016-01-01

    Full Text Available A combined cycle that combines AWM cycle with a nuclear closed Brayton cycle is proposed to recover the waste heat rejected from the precooler of a nuclear closed Brayton cycle in this paper. The detailed thermodynamic and economic analyses are carried out for the combined cycle. The effects of several important parameters, such as the absorber pressure, the turbine inlet pressure, the turbine inlet temperature, the ammonia mass fraction, and the ambient temperature, are investigated. The combined cycle performance is also optimized based on a multiobjective function. Compared with the closed Brayton cycle, the optimized power output and overall efficiency of the combined cycle are higher by 2.41% and 2.43%, respectively. The optimized LEC of the combined cycle is 0.73% lower than that of the closed Brayton cycle.

  18. Combined heat treatment and acid hydrolysis of cassava grate waste (CGW) biomass for ethanol production

    Energy Technology Data Exchange (ETDEWEB)

    Agu, R.C.; Amadife, A.E.; Ude, C.M.; Onyia, A.; Ogu, E.O. [Enugu State Univ. of Science and Technology (Nigeria). Faculty of Applied Natural Sciences; Okafor, M.; Ezejiofor, E. [Nnamdi Azikiwe Univ., Awka (Nigeria). Dept. of Applied Microbiology

    1997-12-31

    The effect of combined heat treatment and acid hydrolysis (various concentrations) on cassava grate waste (CGW) biomass for ethanol production was investigated. At high concentrations of H{sub 2}SO{sub 4} (1--5 M), hydrolysis of the CGW biomass was achieved but with excessive charring or dehydration reaction. At lower acid concentrations, hydrolysis of CGW biomass was also achieved with 0.3--0.5 M H{sub 2}SO{sub 4}, while partial hydrolysis was obtained below 0.3 M H{sub 2}SO{sub 4} (the lowest acid concentration that hydrolyzed CGW biomass) at 120 C and 1 atm pressure for 30 min. A 60% process efficiency was achieved with 0.3 M H{sub 2}SO{sub 4} in hydrolyzing the cellulose and lignin materials present in the CGW biomass. High acid concentration is therefore not required for CGW biomass hydrolysis. The low acid concentration required for CGW biomass hydrolysis, as well as the minimal cost required for detoxification of CGW biomass because of low hydrogen cyanide content of CGW biomass would seem to make this process very economical. From three liters of the CGW biomass hydrolysate obtained from hydrolysis with 0.3M H{sub 2}SO{sub 4}, ethanol yield was 3.5 (v/v%) after yeast fermentation. However, although the process resulted in gainful utilization of CGW biomass, additional costs would be required to effectively dispose new by-products generated from CGW biomass processing.

  19. Multifunctional wall coating combining photocatalysis, self-cleaning and latent heat storage

    Science.gov (United States)

    Lucas, S. S.; Barroso de Aguiar, J. L.

    2018-02-01

    Mortars, one of the most common construction materials, have not received any substantial modification for many decades. This has changed in recent years; new compositions are now being developed, with new properties, using nano-additives, fibres and capsules. In this work, surfaces with new and innovative functionalities that promote energy savings and improve air quality have been developed and studied. Incorporation of phase change materials (PCM) and titanium dioxide (TiO2) nanoparticles in construction products is currently under study by different research groups. However, these studies only address their incorporation separately. Adding new additives into the mortar’s matrix can be complex—due to microstructural modifications that will influence both fresh and hardened state properties. Moving from a single additive to multiple additions, as in this study, increases the system’s complexity. Only with a good understanding of the microstructural properties, it is possible to add multiple additives (including nano and microparticles) to mortars, without damaging its final quality. This work demonstrates that a higher additive content is not always a guarantee of better results; lower additions can often provide a better compromise between performance and final mechanical properties. The results presented in this paper confirmed this and show that combining PCM microcapsules and TiO2 nanoparticles open a new path in the development of mortars with multiple functionalities. In this study, a new material with depolluting, self-cleaning and heat storage was created. For the development of new and innovative mortars, a proper balance of multiple additives, supported by the study of microstructural changes, can lead to an optimization of the compositions, ensuring that the mortar’s final properties are not affected.

  20. Combined scheduling of electricity and heat in a microgrid with volatile wind power

    DEFF Research Database (Denmark)

    Xu, Lizhong; Yang, Guang Ya; Xu, Zhao

    2011-01-01

    An optimization model is developed for scheduling electricity and heat production in a microgrid under a day-ahead market environment considering the operation constraints and the volatility of wind power generation. The model optimizes the total operation costs from energy and heating consumptio...

  1. Efficient on-chip hotspot removal combined solution of thermoelectric cooler and mini-channel heat sink

    International Nuclear Information System (INIS)

    Hao, Xiaohong; Peng, Bei; Xie, Gongnan; Chen, Yi

    2016-01-01

    Highlights: • A combined solution of thermoelectric cooler (TEC) and mini-channel heat sink to remove the hotspot of the chip has been proposed. • The TEC's mathematical model is established to assess its work performance. • A comparative study on the proposed efficient On-Chip Hotspot Removal Combined Solution. - Abstract: Hotspot will significantly degrade the reliability and performance of the electronic equipment. The efficient removal of hotspot can make the temperature distribution uniform, and ensure the reliable operation of the electronic equipment. This study proposes a combined solution of thermoelectric cooler (TEC) and mini-channel heat sink to remove the hotspot of the chip in the electronic equipment. Firstly, The TEC's mathematical model is established to assess its work performance under different boundary conditions. Then, the hotspot removal capability of the TEC is discussed for different cooling conditions, which has shown that the combined equipment has better hotspot removal capability compared with others. Finally, A TEC is employed to investigate the hotspot removal capacity of the combined solution, and the results have indicated that it can effectively remove hotspot in the diameter of 0.5 mm, the power density of 600W/cm 2 when its working current is 3A and heat transfer thermal resistance is 0 K/W.

  2. Techno-economic analysis of a coal-fired CHP based combined heating system with gas-fired boilers for peak load compensation

    International Nuclear Information System (INIS)

    Wang Haichao; Jiao Wenling; Lahdelma, Risto; Zou Pinghua

    2011-01-01

    Combined heat and power (CHP) plants dominate the heating market in China. With the ongoing energy structure reformation and increasing environmental concerns, we propose gas-fired boilers to be deployed in underperforming heating substations of heating networks for peak load compensation, in order to improve both energy efficiency and environmental sustainability. However, due to the relatively high price of gas, techno-economic analysis is required for evaluating different combined heating scenarios, characterized by basic heat load ratio (β). Therefore, we employ the dynamic economics and annual cost method to develop a techno-economic model for computing the net heating cost of the system, considering the current state of the art of cogeneration systems in China. The net heating cost is defined as the investment costs and operations costs of the system subtracted by revenues from power generation. We demonstrate the model in a real-life combined heating system of Daqing, China. The results show that the minimum net heating cost can be realized at β=0.75 with a cost reduction of 16.8% compared to coal heating alone. Since fuel cost is the dominating factor, sensitivity analyses on coal and gas prices are discussed subsequently. - Highlights: ► Combined heating systems comply with the energy structure reformation in China. ► We consider the current state of the art of cogeneration systems in China. ► Combined heating systems can be economically more feasible and sustainable. ► The net heating cost of a combined heating system is more sensitive to coal price. ► The optimal basic heat load ratio is more easily influenced by gas price.

  3. The Added Economic and Environmental Value of Solar Thermal Systems in Microgrids with CombinedHeat and Power

    Energy Technology Data Exchange (ETDEWEB)

    Marnay, Chris; Stadler, Michael; Cardoso, Goncalo; Megel, Olivier; Lai, Judy; Siddiqui, Afzal

    2009-08-15

    The addition of solar thermal and heat storage systems can improve the economic, as well as environmental attraction of micro-generation systems, e.g. fuel cells with or without combined heat and power (CHP) and contribute to enhanced CO2 reduction. However, the interactions between solar thermal collection and storage systems and CHP systems can be complex, depending on the tariff structure, load profile, etc. In order to examine the impact of solar thermal and heat storage on CO2 emissions and annual energy costs, a microgrid's distributed energy resources (DER) adoption problem is formulated as a mixed-integer linear program. The objective is minimization of annual energy costs. This paper focuses on analysis of the optimal interaction of solar thermal systems, which can be used for domestic hot water, space heating and/or cooling, and micro-CHP systems in the California service territory of San Diego Gas and Electric (SDG&E). Contrary to typical expectations, our results indicate that despite the high solar radiation in southern California, fossil based CHP units are dominant, even with forecast 2020 technology and costs. A CO2 pricing scheme would be needed to incent installation of combined solar thermal absorption chiller systems, and no heat storage systems are adopted. This research also shows that photovoltaic (PV) arrays are favored by CO2 pricing more than solar thermal adoption.

  4. The Added Economic and Environmental Value of Solar Thermal Systems in Microgrids with CombinedHeat and Power

    International Nuclear Information System (INIS)

    Marnay, Chris; Stadler, Michael; Cardoso, Goncalo; Megel, Olivier; Lai, Judy; Siddiqui, Afzal

    2009-01-01

    The addition of solar thermal and heat storage systems can improve the economic, as well as environmental attraction of micro-generation systems, e.g. fuel cells with or without combined heat and power (CHP) and contribute to enhanced CO2 reduction. However, the interactions between solar thermal collection and storage systems and CHP systems can be complex, depending on the tariff structure, load profile, etc. In order to examine the impact of solar thermal and heat storage on CO2 emissions and annual energy costs, a microgrid's distributed energy resources (DER) adoption problem is formulated as a mixed-integer linear program. The objective is minimization of annual energy costs. This paper focuses on analysis of the optimal interaction of solar thermal systems, which can be used for domestic hot water, space heating and/or cooling, and micro-CHP systems in the California service territory of San Diego Gas and Electric (SDG and amp;E). Contrary to typical expectations, our results indicate that despite the high solar radiation in southern California, fossil based CHP units are dominant, even with forecast 2020 technology and costs. A CO2 pricing scheme would be needed to incent installation of combined solar thermal absorption chiller systems, and no heat storage systems are adopted. This research also shows that photovoltaic (PV) arrays are favored by CO2 pricing more than solar thermal adoption.

  5. Effects of combined heat and ionizing radiation on thiamine (Vitamin B1) content in model systems and food matrices

    International Nuclear Information System (INIS)

    Chuaqui-Offermanns, N.; Shoemaker, L.; McDougall, T.

    1989-01-01

    The effects of heat and radiation on thiamine stability are being studied both singly and in combination. Heat, γ-radiation and a combination of them were applied to a model system consisting of 2 x 10 -5 M thiamine hydrochloride in 0.01N HCl (pH=2.5), and their effects are reported. The effects of these two agents on thiamine in two food matrices, concentrated orange juice and green peas, are also reported. Heat was not found to have a significant effect on thiamine in the model system at temperatures up to 120 0 C for up to 60 min of treatment. A small, but significant heat effect was found in the two foods. The retention of thiamine in the model system and in the two foods decreased exponentially as the radiation dose increased. The degradation of thiamine by γ-radiation in both foods was a factor of 10 less than that observed in the model system. A small, but significant synergistic effect was found when samples of the model system were heated at 120 0 C for one hour 24 h after irradiation. (author)

  6. Heat Modeling and Material Development of Mg-Based Nanomaterials Combined with Solid Oxide Fuel Cell for Stationary Energy Storage

    Directory of Open Access Journals (Sweden)

    Huaiyu Shao

    2017-11-01

    Full Text Available Mg-based materials have been investigated as hydrogen storage materials, especially for possible onboard storage in fuel cell vehicles for decades. Recently, with the development of large-scale fuel cell technologies, the development of Mg-based materials as stationary storage to supply hydrogen to fuel-cell components and provide electricity and heat is becoming increasingly promising. In this work, numerical analysis of heat balance management for stationary solid oxide fuel cell (SOFC systems combined with MgH2 materials based on a carbon-neutral design concept was performed. Waste heat from the SOFC is supplied to hydrogen desorption as endothermic heat for the MgH2 materials. The net efficiency of this model achieves 82% lower heating value (LHV, and the efficiency of electrical power output becomes 68.6% in minimizing heat output per total energy output when all available heat of waste gas and system is supplied to warm up the storage. For the development of Mg-based hydrogen storage materials, various nano-processing techniques have been widely applied to synthesize Mg-based materials with small particle and crystallite sizes, resulting in good hydrogen storage kinetics, but poor thermal conductivity. Here, three kinds of Mg-based materials were investigated and compared: 325 mesh Mg powers, 300 nm Mg nanoparticles synthesized by hydrogen plasma metal reaction, and Mg50Co50 metastable alloy with body-centered cubic structure. Based on the overall performances of hydrogen capacity, absorption kinetics and thermal conductivity of the materials, the Mg nanoparticle sample by plasma synthesis is the most promising material for this potential application. The findings in this paper may shed light on a new energy conversion and utilization technology on MgH2-SOFC combined concept.

  7. Preliminary study concerning the influence of combined heat and radiation treatment on the quality of some horticultural products

    International Nuclear Information System (INIS)

    Langerak, D.Is.; Bruurs, M.F.J.

    1973-01-01

    In collaboration with a canning factory a number of horticultural products were preserved by means of the combined irradiation and heating treatment. The aim was to study the influence of the parameters irradiation and heat on quality and microbiological spoilage. The products were exposed to gamma-rays with doses varying from 0 to 1 Mrad. The heat treatment varied from 5 to 40 minutes at 98 to 121 0 C; time and temperature depended on the type of product. The sterilization value (F value) was measured by means of the method of Esty and Meyer for products with pH>5. The canned products were stored afterwards at 20-55 0 C. The organoleptic test showed that the colour and texture of most products were improved by the combined treatment, provided the irradiation dose did not exceed 0.25 Mrad. Strawberries in syrup discoloured at 0.1 Mrad. For a number of products the improved colour was partially lost during storage. Flavour and taste were not generally influenced unfavourably at doses up to 0.3 Mrad (exception: strawberries). The treatment sequence did not affect distinctly the quality or microbiological spoilage. The sterilization time (F value) of the combined treatment was determined by the shortest heating period required for the tenderness of the product. (F.J.)

  8. Quantum Gross-Pitaevskii Equation

    Directory of Open Access Journals (Sweden)

    Jutho Haegeman, Damian Draxler, Vid Stojevic, J. Ignacio Cirac, Tobias J. Osborne, Frank Verstraete

    2017-07-01

    Full Text Available We introduce a non-commutative generalization of the Gross-Pitaevskii equation for one-dimensional quantum gasses and quantum liquids. This generalization is obtained by applying the time-dependent variational principle to the variational manifold of continuous matrix product states. This allows for a full quantum description of many body system ---including entanglement and correlations--- and thus extends significantly beyond the usual mean-field description of the Gross-Pitaevskii equation, which is known to fail for (quasi one-dimensional systems. By linearizing around a stationary solution, we furthermore derive an associated generalization of the Bogoliubov -- de Gennes equations. This framework is applied to compute the steady state response amplitude to a periodic perturbation of the potential.

  9. A dynamic regrouping based sequential dynamic programming algorithm for unit commitment of combined heat and power systems

    DEFF Research Database (Denmark)

    Rong, Aiying; Hakonen, Henri; Lahdelma, Risto

    2009-01-01

    This paper addresses the unit commitment (UC) in multi-period combined heat and power (CHP) production planning under the deregulated power market. In CHP plants (units), generation of heat and power follows joint characteristics, which implies that it is difficult to determine the relative cost...... efficiency of the plants. We introduce in this paper the DRDP-RSC algorithm, which is a dynamic regrouping based dynamic programming (DP) algorithm based on linear relaxation of the ON/OFF states of the units, sequential commitment of units in small groups. Relaxed states of the plants are used to reduce...

  10. Optimal Design of Cogeneration Systems in Industrial Plants Combined with District Heating/Cooling and Underground Thermal Energy Storage

    Directory of Open Access Journals (Sweden)

    Vincenzo Dovì

    2011-12-01

    Full Text Available Combined heat and power (CHP systems in both power stations and large plants are becoming one of the most important tools for reducing energy requirements and consequently the overall carbon footprint of fundamental industrial activities. While power stations employ topping cycles where the heat rejected from the cycle is supplied to domestic and industrial consumers, the plants that produce surplus heat can utilise bottoming cycles to generate electrical power. Traditionally the waste heat available at high temperatures was used to generate electrical power, whereas energy at lower temperatures was either released to the environment or used for commercial or domestic heating. However the introduction of new engines, such as the ones using the organic Rankine cycle, capable of employing condensing temperatures very close to the ambient temperature, has made the generation of electrical power at low temperatures also convenient. On the other hand, district heating is becoming more and more significant since it has been extended to include cooling in the warm months and underground storage of thermal energy to cope with variable demand. These developments imply that electric power generation and district heating/cooling may become alternative and not complementary solutions for waste energy of industrial plants. Therefore the overall energy management requires the introduction of an optimisation algorithm to select the best strategy. In this paper we propose an algorithm for the minimisation of a suitable cost function, for any given variable heat demand from commercial and domestic users, with respect to all independent variables, i.e., temperatures and flowrates of warm fluid streams leaving the plants and volume and nature of underground storage. The results of the preliminary process integration analysis based on pinch technology are used in this algorithm to provide bounds on the values of temperatures.

  11. Experimental investigations of heat transfer in thermo active building systems in combination with suspended ceilings

    DEFF Research Database (Denmark)

    Alvarez, Maria Alonso; Hviid, Christian Anker; Weitzmann, Peter

    2014-01-01

    Thermo Active Building Systems (TABS), described as radiant heating or cooling systems with pipes embedded in the building structure, represent a sustainable alternative to replace conventional systems by using source temperatures close to room temperatures. The use of suspended ceiling in office...... buildings to cover acoustic requirements hinders the use of TABS. To measure the reduction of the heat capacity, several experiments are performed in a room equipped with TABS in the upper deck and mixing ventilation. The heat transfer is measured for different suspended ceiling covering percentages...

  12. Influence of dimethyl dicarbonate on the resistance of Escherichia coli to a combined UV-Heat treatment in apple juice

    Science.gov (United States)

    Gouma, Maria; Gayán, Elisa; Raso, Javier; Condón, Santiago; Álvarez, Ignacio

    2015-01-01

    Commercial apple juice inoculated with Escherichia coli was treated with UV-C, heat (55°C) and dimethyl dicarbonate – DMDC (25, 50, and 75 mg/L)-, applied separately and in combination, in order to investigate the possibility of synergistic lethal effects. The inactivation levels resulting from each treatment applied individually for a maximum treatment time of 3.58 min were limited, reaching 1.2, 2.9, and 0.06 log10 reductions for UV, heat, and DMDC (75 mg/L), respectively. However, all the investigated combinations resulted in a synergistic lethal effect, reducing the total treatment time and UV dose, with the synergistic lethal effect being higher when larger concentrations of DMDC were added to the apple juice. The addition of 75 mg/L of DMDC prior to the combined UV-C light treatment at 55°C resulted in 5 log10 reductions after only 1.8 min, reducing the treatment time and UV dose of the combined UV-Heat treatment by 44%. PMID:26042117

  13. Heat treatment in combination with antagonistic yeast reduces diseases and elicits the active defense responses in harvested cherry tomato fruit.

    Science.gov (United States)

    Zhao, Yan; Tu, Kang; Su, Jing; Tu, Sicong; Hou, Yuepeng; Liu, Fengjuan; Zou, Xiurong

    2009-08-26

    This study investigated the effects of heat treatment (hot air at 38 degrees C) and antagonistic yeast (Pichia guilliermondii) alone or in combination against postharvest diseases (Botrytis cinerea, Alternaria alternata and Rhizopus nigricans) on cherry tomato fruit, and evaluated the elicitation of active defense responses. Results showed that heat treatment at 38 degrees C for 24 h in combination with P. guilliermondii at 1 x 10(8) CFU mL(-1) was the most effective approach to reduce various infections on cherry tomato fruit's wounds. Moreover, the combined heat and P. guilliermondii treatment stimulated a rapid increase of H(2)O(2) and higher lignin deposition in cherry tomato fruit showing that the oxidative burst and biological synthesis of lignin might play important roles in the fruit's active defense responses. In addition, the reduction of the fruit's susceptibility to pathogens by the combined treatment was positively correlated with higher activities of phenylalanine ammonia-lyase (PAL) and beta-1,3-glucanase in cherry tomato fruits, both of which are associated with plant defense responses.

  14. Influence of dimethyl dicarbonate on the resistance of Escherichia coli to a combined UV-Heat treatment in apple juice.

    Directory of Open Access Journals (Sweden)

    Maria eGouma

    2015-05-01

    Full Text Available Commercial apple juice inoculated with Escherichia coli was treated with UV-C, heat (55°C and Dimethyl Dicarbonate - DMDC (25, 50 and 75 mg/L-, applied separately and in combination, in order to investigate the possibility of synergistic lethal effects. The inactivation levels resulting from each treatment applied individually for a maximum treatment time of 3.58 min were limited, reaching 1.2, 2.9 and 0.06 Log10 reductions for UV, heat and DMDC (75 mg/L, respectively. However, all the investigated combinations resulted in a synergistic lethal effect, reducing the total treatment time and UV dose, with the synergistic lethal effect being higher when larger concentrations of DMDC were added to the apple juice. The addition of 75 mg/L of DMDC prior to the combined UV-C light treatment at 55°C resulted in 5 Log10 reductions after only 1.8 min, reducing the treatment time and UV dose of the combined UV-Heat treatment by 44%.

  15. Heating and dehydration of grain and cereals at a combined energy supply

    Directory of Open Access Journals (Sweden)

    Sergey Zverev

    2018-02-01

    Full Text Available The paper dwells on the development of experimental dependencies of heating and dehydration of grain and cereals when varying the irradiance, ambient temperature in the heat treatment zone and the initial moisture content of product, and the development of the mathematical models for heating and dehydration of some grains and cereals. The grain was heated on the laboratory equipment with quartz halogen linear infrared emitters. The irradiance on the working surface in the treatment zone was determined by calculation using a specially developed program. The ambient temperature was determined by a thermocouple thermometer placed in a ceramic tube. The grain temperature was estimated as average by weight by a thermocouple thermometer after its transfer into a thermally insulated container. The following dependencies have been obtained: 1 - Temperature dependence of the heating time for different heating modes and initial moisture content. 2 - Dependence of moisture content on the heating time under different conditions and initial moisture content. 3 - Dependence of moisture content on a temperature under different conditions and constant initial humidity. The models of the heat-moisture exchange and dehydration processes have been created, and the model parameters K0 and KT of the temperature dependence of some grains have been identified, as well as their dependence on moisture content and treatment modes has been evaluated. It has been established that this model describes adequately the process of dehydration to an extent limited by the upper temperature value of grain not much more than 100 ºС. Within not limited to the upper temperature value of grain not much more than 100 ºС. From the presented graphs and earlier obtained results for barley and millet, it can be assumed that the model describes adequately experimental data on the small-sized (3 - 5 mm objects.

  16. A method for distributed power consumption based on the combined heat and power system

    Science.gov (United States)

    Li, Si-wei; Han, Shen-zhao; Yu, Bo; Lu, Xin; Qi, Wen

    2018-02-01

    With the development of the society and human progress, now resource problems has become one of the major problems faced by people all over the world, the development of new energy and clean energy is the priority now, is now the main power system. Winter heating is one of the main sources of pollution now, so it is very important to study the electric heating system.

  17. Nusselt number evaluation for combined radiative and convective heat transfer in flow of gaseous products from combustion

    Directory of Open Access Journals (Sweden)

    Trabelsi Soraya

    2013-01-01

    Full Text Available Combined convection and radiation in simultaneously developing laminar flow and heat transfer is numerically considered with a discrete-direction method. Coupled heat transfer in absorbing emitting but not scattering gases is presented in some cases of practical situations such as combustion of natural gas, propane and heavy fuel. Numerical calculations are performed to evaluate the thermal radiation effects on heat transfer through combustion products flowing inside circular ducts. The radiative properties of the flowing gases are modeled by using the absorption distribution function (ADF model. The fluid is a mixture of carbon dioxide, water vapor, and nitrogen. The flow and energy balance equations are solved simultaneously with temperature dependent fluid properties. The bulk mean temperature variations and Nusselt numbers are shown for a uniform inlet temperature. Total, radiative and convective mean Nusselt numbers and their axial evolution for different gas mixtures produced by combustion with oxygen are explored.

  18. Multiple roads lead to Rome: combined high-intensity aerobic and strength training vs. gross motor activities leads to equivalent improvement in executive functions in a cohort of healthy older adults.

    Science.gov (United States)

    Berryman, Nicolas; Bherer, Louis; Nadeau, Sylvie; Lauzière, Séléna; Lehr, Lora; Bobeuf, Florian; Lussier, Maxime; Kergoat, Marie Jeanne; Vu, Thien Tuong Minh; Bosquet, Laurent

    2014-01-01

    The effects of physical activity on cognition in older adults have been extensively investigated in the last decade. Different interventions such as aerobic, strength, and gross motor training programs have resulted in improvements in cognitive functions. However, the mechanisms underlying the relationship between physical activity and cognition are still poorly understood. Recently, it was shown that acute bouts of exercise resulted in reduced executive control at higher relative exercise intensities. Considering that aging is characterized by a reduction in potential energy ([Formula: see text] max - energy cost of walking), which leads to higher relative walking intensity for the same absolute speed, it could be argued that any intervention aimed at reducing the relative intensity of the locomotive task would improve executive control while walking. The objective of the present study was to determine the effects of a short-term (8 weeks) high-intensity strength and aerobic training program on executive functions (single and dual task) in a cohort of healthy older adults. Fifty-one participants were included and 47 (age, 70.7 ± 5.6) completed the study which compared the effects of three interventions: lower body strength + aerobic training (LBS-A), upper body strength + aerobic training (UBS-A), and gross motor activities (GMA). Training sessions were held 3 times every week. Both physical fitness (aerobic, neuromuscular, and body composition) and cognitive functions (RNG) during a dual task were assessed before and after the intervention. Even though the LBS-A and UBS-A interventions increased potential energy to a higher level (Effect size: LBS-A-moderate, UBS-A-small, GMA-trivial), all groups showed equivalent improvement in cognitive function, with inhibition being more sensitive to the intervention. These findings suggest that different exercise programs targeting physical fitness and/or gross motor skills may lead to equivalent improvement in

  19. NM Gross Receipts January - June 2012

    Data.gov (United States)

    Earth Data Analysis Center, University of New Mexico — This layer represents boundaries for New Mexico's gross receipts tax districts as identified on the "Gross Receipts Tax Rate Schedule" published by the Taxation and...

  20. NM Gross Receipts July - December 2012

    Data.gov (United States)

    Earth Data Analysis Center, University of New Mexico — This layer represents boundaries for New Mexico's gross receipts tax districts as identified on the "Gross Receipts Tax Rate Schedule" published by the Taxation and...

  1. NM Gross Receipts July - December 2013

    Data.gov (United States)

    Earth Data Analysis Center, University of New Mexico — This layer represents boundaries for New Mexico's gross receipts tax districts as identified on the "Gross Receipts Tax Rate Schedule" published by the Taxation and...

  2. NM Gross Receipts January - June 2013

    Data.gov (United States)

    Earth Data Analysis Center, University of New Mexico — This layer represents boundaries for New Mexico's gross receipts tax districts as identified on the "Gross Receipts Tax Rate Schedule" published by the Taxation and...

  3. NM Gross Receipts January - June 2011

    Data.gov (United States)

    Earth Data Analysis Center, University of New Mexico — This layer represents boundaries for New Mexico's gross receipts tax districts as identified on the "Gross Receipts Tax Rate Schedule" published by the Taxation and...

  4. NM Gross Receipts January - June 2014

    Data.gov (United States)

    Earth Data Analysis Center, University of New Mexico — This layer represents boundaries for New Mexico's gross receipts tax districts as identified on the "Gross Receipts Tax Rate Schedule" published by the Taxation and...

  5. Combined Heat and Power: Effective Energy Solutions for a Sustainable Future

    Energy Technology Data Exchange (ETDEWEB)

    Shipley, Ms. Anna [Sentech, Inc.; Hampson, Anne [Energy and Environmental Analysis, Inc., an ICF Company; Hedman, Mr. Bruce [Energy and Environmental Analysis, Inc., an ICF Company; Garland, Patricia W [ORNL; Bautista, Paul [Sentech, Inc.

    2008-12-01

    Combined Heat and Power (CHP) solutions represent a proven and effective near-term energy option to help the United States enhance energy efficiency, ensure environmental quality, promote economic growth, and foster a robust energy infrastructure. Using CHP today, the United States already avoids more than 1.9 Quadrillion British thermal units (Quads) of fuel consumption and 248 million metric tons of carbon dioxide (CO{sub 2}) emissions annually compared to traditional separate production of electricity and thermal energy. This CO{sub 2} reduction is the equivalent of removing more than 45 million cars from the road. In addition, CHP is one of the few options in the portfolio of energy alternatives that combines environmental effectiveness with economic viability and improved competitiveness. This report describes in detail the four key areas where CHP has proven its effectiveness and holds promise for the future as an: (1) Environmental Solution: Significantly reducing CO{sub 2} emissions through greater energy efficiency; (2) Competitive Business Solution: Increasing efficiency, reducing business costs, and creating green-collar jobs; (3) Local Energy Solution: Deployable throughout the US; and (4) Infrastructure Modernization Solution: Relieving grid congestion and improving energy security. CHP should be one of the first technologies deployed for near-term carbon reductions. The cost-effectiveness and near-term viability of widespread CHP deployment place the technology at the forefront of practical alternative energy solutions such as wind, solar, clean coal, biofuels, and nuclear power. Clear synergies exist between CHP and most other technologies that dominate the energy and environmental policy dialogue in the country today. As the Nation transforms how it produces, transports, and uses the many forms of energy, it must seize the clear opportunity afforded by CHP in terms of climate change, economic competitiveness, energy security, and infrastructure

  6. Improving crystal size distribution by internal seeding combined cooling/antisolvent crystallization with a cooling/heating cycle

    Science.gov (United States)

    Lenka, Maheswata; Sarkar, Debasis

    2018-03-01

    This work investigates the effect of internal seeding and an initial cooling/heating cycle on the final crystal size distribution (CSD) during a combined cooling/antisolvent crystallization of L-asparagine monohydrate from it's aqueous solution using isopropyl-alcohol as antisolvent. Internal seeds were generated by one-pot addition of various amounts of antisolvent to the crystallizer. It was then followed by a cooling/heating cycle to dissolve the fines produced and thus obtain a suitable initial seed. A combined cooling/antisolvent crystallization was then followed by employing a linear cooling profile with simultaneous addition of antisolvent with a constant mass flow rate to promote the growth of the internally generated seeds. The amount of initial antisolvent influences the characteristics of the internal seeds generated and the effect of initial amount of antisolvent on the final CSD is investigated. It was found that the introduction of a single cooling/heating cycle significantly improves the reproducibility of final CSD as well as the mean size. Overall, the study indicates that the application of internal seeding with a single cooling/heating cycle for fines dissolution is an effective technique to tailor crystal size distribution.

  7. New market based price regulation on combined heat and power in Denmark

    International Nuclear Information System (INIS)

    Koch, Jesper; Nielsen, Marianne; Hansen, Anders B.; Lawaetz, Henrik

    2003-01-01

    Major economic risks can become reality when local co-generation plants (L-CHP ) meet the full market penetration with new market based price regulation. Co-generation produces more than 50% of the national electricity consumption and half of the production is generated from L-CHP. The new price regulation is assumed to take action in 2004. The paper will present an analysis of a market based price regulation on the L-CHP-sector. The paper will spotlight on L-CHP in district heating systems supplying heat for domestic purposes. When smaller and medium sized CHP sell electricity they are paid an average price of 46 Euro per MWh. The return of selling electricity shall primarily cover the expenditure of buying gas for electricity production and writing off investments cost of a CHP-plant. With the framework of today it is a fact that the plants (in average) are only slightly competitive compared to individual heat production plants. When CHP meet market conditions there is a high risk that electricity prices will be reduced significantly (prices of 20 - 30 Euro per MWh) for a longer period. Significantly reduced electricity prices will result in dramatically increased heat prices. If no action is taken there will be a potential risk that heat consumers in the smaller and medium sized cities together must pay an extra bill of 200 million Euro each year. It corresponds to an average increase of the heating bill of 300 - 500 Euro per year for an average house. This is far from acceptable. There will also be a high risk that companies with industrial CHP will permanently convert to heat only boiler and only use their CHP occasionally because CHP plants might not be cost-effective when electricity prices are low. These effects can cause a significant increase of the national CO 2 emission

  8. The role of combined heat and power (CHP) in energy and climate policy

    International Nuclear Information System (INIS)

    Conrad, F.

    1993-03-01

    In the energy- and environment context CHP is said to be especially energy saving and climate preserving. This report shows that from the standpoint of energy economics as well as under technical aspects this judgement holds true only under special conditions. Depending on the technical parameters, the concrete circumstances of operation and the characteristics of the power plants and heating systems compared to CHP-plants the range of realistic energy savings turns out to be very large. Related overstimations are to a good extend caused by the traditional practice of granting the energetic advantage of CHP exclusively to the district heating. If this advantage is credited to heat and power as equal shares space heating with cogenerated power of 80% efficiency reveals to be very energy conserving. The uno actu utilization of cogenerated heat and power, for the same purpose could facilitate the expansion of CHP, since the problems related to the feeding of cogenerated power into the grid for general purposes would disappear. The second main issue of this report concerns the abatement of CO 2 -emissions with the aid of CHP. Fuelled with natural gas, CHP-plants are attractive instruments for climate policy. This is especially true if CHP is compared to old coal-based power plants and oil-fuelled old heating systems. In the FRG, however, hard coal, and not natural gas, will be the main fuel for future CHP, lowering its CO 2 -advantage considerably. On the other hand high efficient combi-power plants (gas turbine plus condensing turbine) and gas heating systems have to be included in the comparative analyse. Compared to these advanced systems the CO 2 -characteristics of CHP are inferior. Moreover, the specific CO 2 -advantage of natural gas is better used by such modern mono systems rather than CHP-plants. (orig.) [de

  9. Heat exposure in cities: combining the dynamics of temperature and population

    Science.gov (United States)

    Hu, L.; Wilhelmi, O.; Uejio, C. K.

    2017-12-01

    Assessment of human exposure to extreme heat requires the distributions of temperature and population. However, both variables are dynamic, thus presenting many challenges in capturing temperature and population patterns spatially and over time in an urban context. This study aims to improve the understanding of spatiotemporal patterns of urban population exposure to heat, taking Chicago, USA as an example. We estimate the hourly, geographically variable, population distribution considering commute of workers and students in a regular weekday and analyze the diurnal air temperature patterns during different meteorological conditions from satellite observations. The results show a relatively larger temperature increase in less urbanized areas during extreme heat events (EHEs), resulting in a spatially homogeneous temperature distribution over Chicago Metropolitan area. A lake cooling effect is weaker during EHEs. Population dynamics due to daily commute determine higher population density in more urbanized areas during daytime. The city-wide analysis reveals that the exposure is more sensitive to the nighttime temperature increases, and EHEs enhance this sensitivity. The high exposure hotspots are identified at the northwest Chicago, Cicero and Oak Park areas, where the influence from Lake Michigan is weakened, while the spatial extent of high outdoor exposure areas varies diurnally. This study's findings have potential to better inform general heat mitigation strategies during hot summer months and facilitate emergency response during EHEs. Availability of remotely-sensed temperature observations as well as the workers and students commute-adjusted population data allows for the adoption of this study's methodology in other major metropolitan areas. A better understanding of space-time patterns of urban population's exposure to heat will further enable local decision makers to mitigate extreme heat health risks and develop more targeted heat preparedness and

  10. Two-stage absorber systems - Economically viable combined heat and cold generation; Wirtschaftlicher Kraft-Waerme-Kaelte-Verbund

    Energy Technology Data Exchange (ETDEWEB)

    Biniossek, H. [Giesecke und Devrient, Muenchen (Germany); Schmid, W. [Technische Gebaeudeausruestung, Muenchen (Germany)

    2008-07-01

    This article takes a look at how the possibilities of optimising power, heat and cold generation for the German Giesecke and Devrient company were examined and implemented. The company, which produces banknotes and chip-cards, chose the combination of a Combined Heat and Power (CHP) Unit and a two-stage absorber refrigeration system. The company's old system is briefly described and the reasons for replacing it are discussed. The careful dimensioning of the new system and the search for appropriate equipment are described. Intelligent power flows and a cooling system with two different temperature levels are described. Costs saved and emergency power generation are also looked at, as are the complex demands placed on the control of the system. The system's functioning is briefly described.

  11. Energy Analysis of a Complementary Heating System Combining Solar Energy and Coal for a Rural Residential Building in Northwest China

    Science.gov (United States)

    Zhen, Xiaofei; Abdalla Osman, Yassir Idris; Feng, Rong; Zhang, Xuemin

    2018-01-01

    In order to utilize solar energy to meet the heating demands of a rural residential building during the winter in the northwestern region of China, a hybrid heating system combining solar energy and coal was built. Multiple experiments to monitor its performance were conducted during the winter in 2014 and 2015. In this paper, we analyze the efficiency of the energy utilization of the system and describe a prototype model to determine the thermal efficiency of the coal stove in use. Multiple linear regression was adopted to present the dual function of multiple factors on the daily heat-collecting capacity of the solar water heater; the heat-loss coefficient of the storage tank was detected as well. The prototype model shows that the average thermal efficiency of the stove is 38%, which means that the energy input for the building is divided between the coal and solar energy, 39.5% and 60.5% energy, respectively. Additionally, the allocation of the radiation of solar energy projecting into the collecting area of the solar water heater was obtained which showed 49% loss with optics and 23% with the dissipation of heat, with only 28% being utilized effectively. PMID:29651424

  12. Analysis of resonant fast ion distributions during combined ICRF and NBI heating with transients using neutron emission spectroscopy

    Science.gov (United States)

    Hellesen, C.; Mantsinen, M.; Conroy, S.; Ericsson, G.; Eriksson, J.; Kiptily, V. G.; Nabais, F.; Contributors, JET

    2018-05-01

    ICRF heating at the fundamental cyclotron frequency of a hydrogen minority ion species also gives rise to a partial power absorption by deuterium ions at their second harmonic resonance. This paper studies the deuterium distributions resulting from such 2nd harmonic heating at JET using neutron emission spectroscopy data from the time of flight spectrometer TOFOR. The fast deuterium distributions are obtained over the energy range 100 keV to 2 MeV. Specifically, we study how the fast deuterium distributions vary as ICRF heating is used alone as well as in combination with NBI heating. When comparing the different heating scenarios, we observed both a difference in the shapes of the distributions as well as in their absolute level. The differences are most pronounced below 0.5 MeV. Comparisons are made with corresponding distributions calculated with the code PION. We find a good agreement between the measured distributions and those calculated with PION, both in terms of their shapes as well as their amplitudes. However, we also identified a period with signs of an inverted fast ion distribution, which showed large disagreements between the modeled and measured results. Resonant interactions with tornado modes, i.e. core localized toroidal alfven eigenmodes (TAEs), are put forward as a possible explanation for the inverted distribution.

  13. Laboratory Evaluation of Gas-Fired Tankless and Storage Water Heater Approaches to Combination Water and Space Heating

    Energy Technology Data Exchange (ETDEWEB)

    Kingston, T.; Scott, S.

    2013-03-01

    Homebuilders are exploring more cost effective combined space and water heating systems (combo systems) with major water heater manufacturers that are offering pre-engineered forced air space heating combo systems. In this project, unlike standardized tests, laboratory tests were conducted that subjected condensing tankless and storage water heater based combo systems to realistic, coincidental space and domestic hot water loads with the following key findings: 1) The tankless combo system maintained more stable DHW and space heating temperatures than the storage combo system. 2) The tankless combo system consistently achieved better daily efficiencies (i.e. 84%-93%) than the storage combo system (i.e. 81%- 91%) when the air handler was sized adequately and adjusted properly to achieve significant condensing operation. When condensing operation was not achieved, both systems performed with lower (i.e. 75%-88%), but similar efficiencies. 3) Air handlers currently packaged with combo systems are not designed to optimize condensing operation. More research is needed to develop air handlers specifically designed for condensing water heaters. 4) System efficiencies greater than 90% were achieved only on days where continual and steady space heating loads were required with significant condensing operation. For days where heating was more intermittent, the system efficiencies fell below 90%.

  14. Energy Analysis of a Complementary Heating System Combining Solar Energy and Coal for a Rural Residential Building in Northwest China.

    Science.gov (United States)

    Zhen, Xiaofei; Li, Jinping; Abdalla Osman, Yassir Idris; Feng, Rong; Zhang, Xuemin; Kang, Jian

    2018-01-01

    In order to utilize solar energy to meet the heating demands of a rural residential building during the winter in the northwestern region of China, a hybrid heating system combining solar energy and coal was built. Multiple experiments to monitor its performance were conducted during the winter in 2014 and 2015. In this paper, we analyze the efficiency of the energy utilization of the system and describe a prototype model to determine the thermal efficiency of the coal stove in use. Multiple linear regression was adopted to present the dual function of multiple factors on the daily heat-collecting capacity of the solar water heater; the heat-loss coefficient of the storage tank was detected as well. The prototype model shows that the average thermal efficiency of the stove is 38%, which means that the energy input for the building is divided between the coal and solar energy, 39.5% and 60.5% energy, respectively. Additionally, the allocation of the radiation of solar energy projecting into the collecting area of the solar water heater was obtained which showed 49% loss with optics and 23% with the dissipation of heat, with only 28% being utilized effectively.

  15. The Heat Transfer of Microencapsulated Phase Change Material Slurry and Its Thermal Energy Storage Performance of Combined Heat and Power Generating Units

    Directory of Open Access Journals (Sweden)

    Yonghong Guo

    2017-10-01

    Full Text Available The application of thermal energy storage (TES is an effective way of improving the power load regulation capability of combined heat and power (CHP generating units. In this paper, a theoretical investigation on the thermal energy storage system of a CHP unit that employs the microencapsulated phase change material slurry (MPCMS as the working fluid is carried out. The results indicate that the microcapsule particle internal melting rate is progressively small; 90% latent heat can be absorbed in 63% total melting time. The melting time of particles in micron is very short, and the diameter is an important factor for microcapsule melting. For the MPCMS flow in a circular tube, the temperature distribution between laminar flows and turbulent flows is different. In a turbulent flow, there is an approximate isothermal section along the tube, which cannot be found in a laminar flow. Additionally, a thermal storage system with MPCMS as heat transfer fluid for a CHP unit is proposed. A case study for a 300 MW CHP unit found that the use of an MPSMS thermal energy storage system increases the power peak shaving capacity by 81.4%. This indicates that the thermal storage system increases the peak shaving capacity of cogeneration units.

  16. Analytical solutions for tomato peeling with combined heat flux and convective boundary conditions

    Science.gov (United States)

    Cuccurullo, G.; Giordano, L.; Metallo, A.

    2017-11-01

    Peeling of tomatoes by radiative heating is a valid alternative to steam or lye, which are expensive and pollutant methods. Suitable energy densities are required in order to realize short time operations, thus involving only a thin layer under the tomato surface. This paper aims to predict the temperature field in rotating tomatoes exposed to the source irradiation. Therefore, a 1D unsteady analytical model is presented, which involves a semi-infinite slab subjected to time dependent heating while convective heat transfer takes place on the exposed surface. In order to account for the tomato rotation, the heat source is described as the positive half-wave of a sinusoidal function. The problem being linear, the solution is derived following the Laplace Transform Method. In addition, an easy-to-handle solution for the problem at hand is presented, which assumes a differentiable function for approximating the source while neglecting convective cooling, the latter contribution turning out to be negligible for the context at hand. A satisfying agreement between the two analytical solutions is found, therefore, an easy procedure for a proper design of the dry heating system can be set up avoiding the use of numerical simulations.

  17. Numerical study of combined convection heat transfer for thermally developing upward flow in a vertical cylinder

    Directory of Open Access Journals (Sweden)

    Mohammed Hussein A.

    2008-01-01

    Full Text Available The problem of the laminar upward mixed convection heat transfer for thermally developing air flow in the entrance region of a vertical circular cylinder under buoyancy effect and wall heat flux boundary condition has been numerically investigated. An implicit finite difference method and the Gauss elimination technique have been used to solve the governing partial differential equations of motion (Navier Stocks equations for two-dimensional model. This investigation covers Reynolds number range from 400 to 1600, heat flux is varied from 70 W/m2 to 400 W/m2. The results present the dimensionless temperature profile, dimensionless velocity profile, dimensionless surface temperature along the cylinder, and the local Nusselt number variation with the dimensionless axial distance Z+. The dimensionless velocity and temperature profile results have revealed that the secondary flow created by natural convection have a significant effect on the heat transfer process. The results have also shown an increase in the Nusselt number values as the heat flux increases. The results have been compared with the available experimental study and with the available analytical solution for pure forced convection in terms of the local Nusselt number. The comparison has shown satisfactory agreement. .

  18. Modelling a Combined Heat and Power Plant based on Gasification, Micro Gas Turbine and Solid Oxide Fuel Cells

    DEFF Research Database (Denmark)

    Bang-Møller, Christian; Rokni, Masoud

    2009-01-01

    A system level modelling study on two combined heat and power (CHP) systems both based on biomass gasification. One system converts the product gas in a micro gas turbine (MGT) and the other in a combined solid oxide fuel cell (SOFC) and MGT arrangement. An electrochemical model of the SOFC has...... been developed and calibrated against published data from Topsoe Fuel Cells A/S (TOFC) and Risø National Laboratory, and the modelled gasifier is based on an up scaled version of the demonstrated low tar gasifier, Viking, situated at the Technical University of Denmark. The SOFC converts the syngas...

  19. Optimal coordinated scheduling of combined heat and power fuel cell, wind, and photovoltaic units in micro grids considering uncertainties

    International Nuclear Information System (INIS)

    Bornapour, Mosayeb; Hooshmand, Rahmat-Allah; Khodabakhshian, Amin; Parastegari, Moein

    2016-01-01

    In this paper, a stochastic model is proposed for coordinated scheduling of combined heat and power units in micro grid considering wind turbine and photovoltaic units. Uncertainties of electrical market price; the speed of wind and solar radiation are considered using a scenario-based method. In the method, scenarios are generated using roulette wheel mechanism based on probability distribution functions of input random variables. Using this method, the probabilistic specifics of the problem are distributed and the problem is converted to a deterministic one. The type of the objective function, coordinated scheduling of combined heat and power, wind turbine, and photovoltaic units change this problem to a mixed integer nonlinear one. Therefore to solve this problem modified particle swarm optimization algorithm is employed. The mentioned uncertainties lead to an increase in profit. Moreover, the optimal coordinated scheduling of renewable energy resources and thermal units in micro grids increase the total profit. In order to evaluate the performance of the proposed method, its performance is executed on modified 33 bus distributed system as a micro grid. - Highlights: • Stochastic model is proposed for coordinated scheduling of renewable energy sources. • The effect of combined heat and power is considered. • Maximizing profits of micro grid is considered as objective function. • Considering the uncertainties of problem lead to profit increasing. • Optimal scheduling of renewable energy sources and thermal units increases profit.

  20. Effects of Combined Heat and Preservative Treatment on Storability of Ponkan Fruit (Citrus reticulata Blanco cv. Ponkan during Postharvest Storage

    Directory of Open Access Journals (Sweden)

    Dandan Tang

    2017-01-01

    Full Text Available Heat treatment and preservative application have been widely used during postharvest storage of many fresh products, but the effect of their combination on citrus storage has rarely been investigated. In this study, the optimal heat treatment (HT conditions and HT combined with preservative treatment were investigated for Ponkan fruit (Citrus reticulata Blanco cv. Ponkan storage. Results indicated that HT at 55°C for 20 s can significantly reduce the decay rate of Ponkan fruit, and a combination of HT and 25% of the preservative dosage used in production of iminoctadine tris (albesilate, 2,4-dichlorophenoxyacetic acid, and imazalil significantly reduced the decay rate without affecting fruit quality. In addition, the increased fiber contents in fruit receiving the HT combined with preservative treatments may be a response preventing fungus infection and enhancing fruit storability and resistance. The above results suggested that the combination of HT and 25% of the preservative production dosage was optimal for controlling Ponkan fruit decay during storage.

  1. ComfortPower. Design, construction and evaluation of a combined fuel-cell and heat pump system

    Energy Technology Data Exchange (ETDEWEB)

    Silversand, Fredrik (Catator AB, Lund (Sweden))

    2010-12-15

    Catator AB has constructed, commissioned and evaluated a combined fuel-cell and heat-pump system (ComfortPower). The basic idea behind the project was to demonstrate the possibility to achieve ultrahigh thermal efficiencies when combining fuel-cell technologies and heat pumps. Moreover, the system should provide a great flexibility with respect to the fuel mix and should in addition to heat provide surplus electricity and cooling. The system was built on a HT-PEM platform (high temperature polymer electrolyte fuel cell from Serenergy a/s), which was operated by Catators proprietary Optiformer technology. The power generator was combined with a heat pump module (F1145-5, 230 V), supplied by Nibe. The system was packaged into a cabinet (1.65 x 0.6 x 0.6 m) comprising the power module, the heat pump, all necessary balance-of-plant components and the control system. The power output from the fuel-cell system was around 1.35 kW, which enabled operation of the heat pump compressor. By utilizing surplus heat energy from the fuel cell it was possible to achieve a favourable operation point in the heat pump system, resulting in a high overall COP (coefficient of performance). The heat output from the system was as high as 10 kW whereas 6 kW cooling could be provided. The thermal efficiencies measured in experiments were normally around 200%, calculated on the lower heating value of the fuel. A number of fuels have been investigated in the fuel cell system, including both gaseous (natural gas/LPG) and liquid fuels (alcohols and kerosene). Indeed, the system has a wide fuel flexibility, which opens up for a variety of applications in campus villages and buildings. This study has demonstrated the possibility to reduce the carbon dioxide footprint by a factor of 2 over conventional boilers in heating applications. In addition the unit can be operated on a variety of fuels and can produce cooling and electricity in addition to heat. A fully working system has been designed

  2. Combined natural convection heat and mass transfer from vertical fin arrays

    International Nuclear Information System (INIS)

    Giri, A.; Narasimham, G.S.V.L.; Krishna Murthy, M.V.

    2003-01-01

    Natural convection transport processes play an important role in many applications like ice-storage air-conditioning. A mathematical formulation of natural convection heat and mass transfer over a shrouded vertical fin array is developed. The base plate is maintained at a temperature below the dew point of the surrounding moist air. Hence there occurs condensation of moisture on the base plate, while the fins may be partially or fully wet. A numerical study is performed by varying the parameters of the problem. The local and average Nusselt numbers decrease in streamwise direction and tend to approach fully developed values for sufficiently large values of the fin length. The results show that beyond a certain streamwise distance, further fin length does not improve the sensible and latent heat transfer performance, and that if dry fin analysis is used under moisture condensation conditions, the overall heat transfer will be underestimated by about 50% even at low buoyancy ratios

  3. Energy and Exergy Analysis and Optimization of Combined Heat and Power Systems. Comparison of Various Systems

    Directory of Open Access Journals (Sweden)

    Monica Costea

    2012-09-01

    Full Text Available The paper presents a comparison of various CHP system configurations, such as Vapour Turbine, Gas Turbine, Internal Combustion Engine, External Combustion Engine (Stirling, Ericsson, when different thermodynamic criteria are considered, namely the first law efficiency and exergy efficiency. Thermodynamic optimization of these systems is performed intending to maximize the exergy, when various practical related constraints (imposed mechanical useful energy, imposed heat demand, imposed heat to power ratio or main physical limitations (limited heat availability, maximum system temperature allowed, thermo-mechanical constraints are taken into account. A sensitivity analysis to model parameters is given. The results have shown that the various added constraints were useful for the design allowing to precise the influence of the model main parameters on the system design. Future perspective of the work and recommendations are stated.

  4. Subcontract Report: Modular Combined Heat & Power System for Utica College: Design Specification

    Energy Technology Data Exchange (ETDEWEB)

    Rouse, Greg [Gas Technology Institute

    2007-09-01

    Utica College, located in Utica New York, intends to install an on-site power/cogeneration facility. The energy facility is to be factory pre-assembled, or pre- assembled in modules, to the fullest extent possible, and ready to install and interconnect at the College with minimal time and engineering needs. External connections will be limited to fuel supply, electrical output, potable makeup water as required and cooling and heat recovery systems. The proposed facility will consist of 4 self-contained, modular Cummins 330kW engine generators with heat recovery systems and the only external connections will be fuel supply, electrical outputs and cooling and heat recovery systems. This project was eventually cancelled due to changing DOE budget priorities, but the project engineers produced this system design specification in hopes that it may be useful in future endeavors.

  5. Gross anatomy of network security

    Science.gov (United States)

    Siu, Thomas J.

    2002-01-01

    Information security involves many branches of effort, including information assurance, host level security, physical security, and network security. Computer network security methods and implementations are given a top-down description to permit a medically focused audience to anchor this information to their daily practice. The depth of detail of network functionality and security measures, like that of the study of human anatomy, can be highly involved. Presented at the level of major gross anatomical systems, this paper will focus on network backbone implementation and perimeter defenses, then diagnostic tools, and finally the user practices (the human element). Physical security measures, though significant, have been defined as beyond the scope of this presentation.

  6. Combined scheduling of electricity and heat in a microgrid with volatile wind power

    DEFF Research Database (Denmark)

    Xu, Lizhong; Yang, Guang Ya; Xu, Zhao

    2011-01-01

    An optimization model is developed for scheduling electricity and heat production in a microgrid under a day-ahead market environment considering the operation constraints and the volatility of wind power generation. The model optimizes the total operation costs from energy and heating consumption...... into a mixed-integer programming (MIP) problem. Numerical simulations present the efficacy of the proposed model for day-ahead scheduling of a microgrid with wind penetration under the deregulated environment. © 2011 State Grid Electrtic Resarch Institute Press....

  7. Efficiency potentials of heat pumps with combined heat and power. For maximum reduction of CO2 emissions and for electricity generation from fossil fuels with CO2 reduction in Switzerland

    International Nuclear Information System (INIS)

    Rognon, F.

    2005-06-01

    This comprehensive report for the Swiss Federal Office of Energy (SFOE) takes a look at how the efficiency potential of heat pumps together with combined heat and power systems can help provide a maximum reduction of CO 2 emissions and provide electricity generation from fossil fuel in Switzerland together with reductions in CO 2 emissions. In Switzerland, approximately 80% of the low-temperature heat required for space-heating and for the heating-up of hot water is produced by burning combustibles. Around a million gas and oil boilers were in use in Switzerland in 2000, and these accounted for approximately half the country's 41.1 million tonnes of CO 2 emissions. The authors state that there is a more efficient solution with lower CO 2 emissions: the heat pump. With the enormous potential of our environment it would be possible to replace half the total number of boilers in use today with heat pumps. This would be equivalent to 90 PJ p.a. of useful heat, or 500,000 systems. The power source for heat pumps should come from the substitution of electric heating systems (electric resistor-based systems) and from the replacement of boilers. This should be done by using combined heat and power systems with full heat utilisation. This means, according to the authors, that the entire required power source can be provided without the need to construct new electricity production plants. The paper examines and discusses the theoretical, technical, market and realisable potentials

  8. Analysis of combined hydrogen, heat, and power as a bridge to a hydrogen transition.

    Energy Technology Data Exchange (ETDEWEB)

    Mahalik, M.; Stephan, C. (Decision and Information Sciences)

    2011-01-18

    Combined hydrogen, heat, and power (CHHP) technology is envisioned as a means to providing heat and electricity, generated on-site, to large end users, such as hospitals, hotels, and distribution centers, while simultaneously producing hydrogen as a by-product. The hydrogen can be stored for later conversion to electricity, used on-site (e.g., in forklifts), or dispensed to hydrogen-powered vehicles. Argonne has developed a complex-adaptive-system model, H2CAS, to simulate how vehicles and infrastructure can evolve in a transition to hydrogen. This study applies the H2CAS model to examine how CHHP technology can be used to aid the transition to hydrogen. It does not attempt to predict the future or provide one forecast of system development. Rather, the purpose of the model is to understand how the system works. The model uses a 50- by 100-mile rectangular grid of 1-square-mile cells centered on the Los Angeles metropolitan area. The major expressways are incorporated into the model, and local streets are considered to be ubiquitous, except where there are natural barriers. The model has two types of agents. Driver agents are characterized by a number of parameters: home and job locations, income, various types of 'personalities' reflective of marketing distinctions (e.g., innovators, early adopters), willingness to spend extra money on 'green' vehicles, etc. At the beginning of the simulations, almost all driver agents own conventional vehicles. They drive around the metropolitan area, commuting to and from work and traveling to various other destinations. As they do so, they observe the presence or absence of facilities selling hydrogen. If they find such facilities conveniently located along their routes, they are motivated to purchase a hydrogen-powered vehicle when it becomes time to replace their present vehicle. Conversely, if they find that they would be inconvenienced by having to purchase hydrogen earlier than necessary or if they

  9. Corrosion investigations at Masnedoe combined heat and power plants: Part VII[Denmark

    Energy Technology Data Exchange (ETDEWEB)

    Montgomery, M. [Danmarks Tekniske Univ., Dept. for Manufacturing Engineering, Kgs. Lyngby (Denmark); Biede, O. [ENERGI E2 Power Company, Copenhagen (Denmark); Hede Larsen, O. [Elsam - Fynsvaerket, Fredericia (DK)

    2002-12-01

    In Denmark, straw and other types of biomass are used for generating energy in power plats. Straw is considered a carbon dioxide neutral fuel and is therefore environmentally acceptable. Masnedoe CHP Plant is a straw-fired power plant on Sjaelland, Denmark. Corrosion tests were undertaken at Masnedoe CHP Plant by building a test superheater loop and subject it to higher steam temperatures than those of the actual plant. Furthermore, a test section welded into the superheater was investigated. The test superheater loop showed varying corrosion rates that could not be explained by a linear increase in steam temperature over the length of the loop. This was related to the flue gas direction giving a higher surface metal temperature, however, there could be other factors giving localised high heat flux and therefore a higher metal temperature. Using steamside inner oxide thickness, an improved calculation of the metal temperatures was undertaken in order to explain the corrosion rates observed. Thus a variation of heat flux gave temperatures 43 deg. C higher than a linear heat flux. It is important to bear in mind when assessing corrosion rates that a local high heat flux will result in higher metal temperatures in certain parts of a loop and subsequently high corrosion rates. (BA)

  10. Measurements of Combined Axial Mass and Heat Transport in He II.

    Science.gov (United States)

    Johnson, Warren W.; Jones, Michael C.

    An experiment was performed that allowed measurements of both axial mass and heat transport of He-II (the superfluid phase of helium 4) in a long tube. The apparatus allowed the pressure difference and the temperature difference across the flow tube to each be independently adjusted, and the resulting steady-state values of net fluid velocity and…

  11. Industrial Application of Topology Optimization for Combined Conductive and Convective Heat Transfer Problems

    DEFF Research Database (Denmark)

    Zhou, Mingdong; Alexandersen, Joe; Sigmund, Ole

    2016-01-01

    -state heat transfer under convection is simulated using SIMULIA-Abaqus. A corresponding topology optimization feature is provided by SIMULIA-Tosca. By following a standard workflow of design optimization, the proposed solution is able to accommodate practical design scenarios and results in efficient...

  12. The effect of the combined treatment of gamma irradiation and heating on the aerobic bacterial load of white and black peppers

    International Nuclear Information System (INIS)

    Mohd Khan Ayob; Ismail Bahari; Osman Hassan; Verumandy Kaleswaran

    1985-01-01

    The effect of combined heat-irradiation treatment on the aerobic bacterial load of black and white peppers were evaluated in comparison with that of heat or irradiation treatment only. The irradiation doses applied were 0 (control), 2, 4, 6 and 8 kGy and the heating temperatures were 28 (control), 50, 60, 70 and 80 deg C. Results indicated that gamma radiation of 7 kGy and 5 kGy were capable of reducing bacterial population from 3.6 x 10 6 /g and 2.9 x 10 5 /g to 3 /g black and white peppers, respectively. Heating at drying temperature could only reduce the bacterial contaminants to 1/2 log cycle. Combined treatment of irradiation followed by heating is more effective in reducing the bacterial load, and the combined treatment of heating followed by irradiation showed similar effects as in irradiation treatment alone. (author)

  13. Inactivation of Escherichia coli in a tropical fruit smoothie by a combination of heat and pulsed electric fields.

    Science.gov (United States)

    Walkling-Ribeiro, M; Noci, F; Cronin, D A; Lyng, J G; Morgan, D J

    2008-10-01

    Moderate heat in combination with pulsed electric fields (PEF) was investigated as a potential alternative to thermal pasteurization of a tropical fruit smoothie based on pineapple, banana, and coconut milk, inoculated with Escherichia coli K12. The smoothie was heated from 25 degrees C to either 45 or 55 degrees C over 60 s and subsequently cooled to 10 degrees C. PEF was applied at electric field strengths of 24 and 34 kV/cm with specific energy inputs of 350, 500, and 650 kJ/L. Both processing technologies were combined using heat (45 or 55 degrees C) and the most effective set of PEF conditions. Bacterial inactivation was estimated on standard and NaCl-supplemented tryptone soy agar (TSA) to enumerate sublethally injured cells. By increasing the temperature from 45 to 55 degrees C, a higher reduction in E. coli numbers (1 compared with 1.7 log(10) colony forming units {CFU} per milliliter, P field strength was increased during stand-alone PEF treatment from 24 to 34 kV/cm, a greater number of E. coli cells were inactivated (2.8 compared with 4.2 log(10) CFU/mL, P or = 0.05) achieved by thermal pasteurization (72 degrees C, 15 s). A reversed hurdle processing sequence did not affect bacterial inactivation (P> or = 0.05). No differences were observed (P> or = 0.05) between the bacterial counts estimated on nonselective and selective TSA, suggesting that sublethal cell injury did not occur during single PEF treatments or combined heat/PEF treatments.

  14. Combined heat and power systems for commercial buildings: investigating cost, emissions, and primary energy reduction based on system components

    Science.gov (United States)

    Smith, Amanda D.

    Combined heat and power (CHP) systems produce electricity and useful heat from fuel. When power is produced near a building which consumes power, transmission losses are averted, and heat which is a byproduct of power production may be useful to the building. That thermal energy can be used for hot water or space heating, among other applications. This dissertation focuses on CHP systems using natural gas, a common fuel, and systems serving commercial buildings in the United States. First, the necessary price difference between purchased electricity and purchased fuel is analyzed in terms of the efficiencies of system components by comparing CHP with a conventional separate heat and power (SHP) configuration, where power is purchased from the electrical grid and heat is provided by a gas boiler. Similarly, the relationship between CDE due to electricity purchases and due to fuel purchases is analyzed as well as the relationship between primary energy conversion factors for electricity and fuel. The primary energy conversion factor indicates the quantity of source energy necessary to produce the energy purchased at the site. Next, greenhouse gas emissions are investigated for a variety of commercial buildings using CHP or SHP. The relationship between the magnitude of the reduction in emissions and the parameters of the CHP system is explored. The cost savings and reduction in primary energy consumption are evaluated for the same buildings. Finally, a CHP system is analyzed with the addition of a thermal energy storage (TES) component, which can store excess thermal energy and deliver it later if necessary. The potential for CHP with TES to reduce cost, emissions, and primary energy consumption is investigated for a variety of buildings. A case study is developed for one building for which TES does provide additional benefits over a CHP system alone, and the requirements for a water tank TES device are examined.

  15. Heat transfer reduction using combination of spike and counterflow jet on blunt body at high Mach number flow

    Science.gov (United States)

    Eghlima, Z.; Mansour, K.; Fardipour, K.

    2018-02-01

    Heat transfer reduction around blunt bodies is one of the important issues in the field of high speed aerodynamics. Using of spikes and counterflow jets each of them separately for reducing of drag force and heat transfer is well known. The present work is description of flow field around a hemispherical nose cylinder with a combination of spike and counterflow jet at free stream of Mach number of 6. The air gas was injected through the nozzle at the nose of the hemispherical model at sonic speed. In this numerical analysis, axisymmetric Reynolds-averaged Navier-Stokes equations was solved by k-ω (SST) turbulence model. The grid study was done and the results are validated with experimental results for spiked body without jet condition. Then the results presented for different lengths of spike and different pressures of counterflow jets. The results show a significant reduction in the peak heat transfer about 60%-78% for different models compared to the spherical cylinder model without any jet and spike. Furthermore, also our results indicate that the heat transfer reduction is increased even more with increasing of the length of the spike.

  16. Integration of biomass fast pyrolysis and precedent feedstock steam drying with a municipal combined heat and power plant

    International Nuclear Information System (INIS)

    Kohl, Thomas; Laukkanen, Timo P.; Järvinen, Mika P.

    2014-01-01

    Biomass fast pyrolysis (BFP) is a promising pre-treatment technology for converting biomass to transport fuel and in the future also for high-grade chemicals. BFP can be integrated with a municipal combined heat and power (CHP) plant. This paper shows the influence of BFP integration on a CHP plant's main parameters and its effect on the energetic and environmental performance of the connected district heating network. The work comprises full- and part-load operation of a CHP plant integrated with BFP and steam drying. It also evaluates different usage alternatives for the BFP products (char and oil). The results show that the integration is possible and strongly beneficial regarding energetic and environmental performance. Offering the possibility to provide lower district heating loads, the operation hours of the plant can be increased by up to 57%. The BFP products should be sold rather than applied for internal use as this increases the district heating network's primary energy efficiency the most. With this integration strategy future CHP plants can provide valuable products at high efficiency and also can help to mitigate global CO 2 emissions. - Highlights: • Part load simulation of a cogeneration plant integrated with biomas fast pyrolysis. • Analysis of energetic and environmental performance. • Assessment of different uses of the pyrolysis products

  17. Expanding photovoltaic penetration with residential distributed generation from hybrid solar photovoltaic and combined heat and power systems

    International Nuclear Information System (INIS)

    Pearce, J.M.

    2009-01-01

    The recent development of small scale combined heat and power (CHP) systems has provided the opportunity for in-house power backup of residential-scale photovoltaic (PV) arrays. This paper investigates the potential of deploying a distributed network of PV + CHP hybrid systems in order to increase the PV penetration level in the U.S. The temporal distribution of solar flux, electrical and heating requirements for representative U.S. single family residences were analyzed and the results clearly show that hybridizing CHP with PV can enable additional PV deployment above what is possible with a conventional centralized electric generation system. The technical evolution of such PV + CHP hybrid systems was developed from the present (near market) technology through four generations, which enable high utilization rates of both PV-generated electricity and CHP-generated heat. A method to determine the maximum percent of PV-generated electricity on the grid without energy storage was derived and applied to an example area. The results show that a PV + CHP hybrid system not only has the potential to radically reduce energy waste in the status quo electrical and heating systems, but it also enables the share of solar PV to be expanded by about a factor of five. (author)

  18. Enhanced detection of nitrogen dioxide via combined heating and pulsed UV operation of indium oxide nano-octahedra

    Directory of Open Access Journals (Sweden)

    Oriol Gonzalez

    2016-10-01

    Full Text Available We report on the use of combined heating and pulsed UV light activation of indium oxide gas sensors for enhancing their performance in the detection of nitrogen dioxide in air. Indium oxide nano-octahedra were synthesized at high temperature (900 °C via vapour-phase transport and screen-printed onto alumina transducers that comprised interdigitated electrodes and a heating resistor. Compared to the standard, constant temperature operation of the sensor, mild heating (e.g., 100 °C together with pulsed UV light irradiation employing a commercially available, 325 nm UV diode (square, 1 min period, 15 mA drive current signal, results in an up to 80-fold enhancement in sensitivity to nitrogen dioxide. Furthermore, this combined operation method allows for making savings in power consumption that range from 35% to over 80%. These results are achieved by exploiting the dynamics of sensor response under pulsed UV light, which convey important information for the quantitative analysis of nitrogen dioxide.

  19. Performance and costs of a roof-sized PV/thermal array combined with a ground coupled heat pump

    International Nuclear Information System (INIS)

    Bakker, M.; Zondag, H.A.; Elswijk, M.J.; Strootman, K.J.; Jong, M.J.M.

    2005-01-01

    A photovoltaic/thermal (PVT) panel is a combination of photovoltaic cells with a solar thermal collector, generating solar electricity and solar heat simultaneously. Hence, PVT panels are an alternative for a combination of separate PV panels and solar thermal collectors. A promising system concept, consisting of 25 m 2 of PVT panels and a ground coupled heat pump, has been simulated in TRNSYS. It has been found that this system is able to cover 100% of the total heat demand for a typical newly-built Dutch one-family dwelling, while covering nearly all of its own electricity use and keeping the long-term average ground temperature constant. The cost of such a system has been compared to the cost of a reference system, where the PVT panels have been replaced with separate PV panels (26 m 2 ) and solar thermal collectors (7 m 2 ), but which is otherwise identical. The electrical and thermal yield of this reference system is equal to that of the PVT system. It has been found that both systems require a nearly identical initial investment. Finally, a view on future PVT markets is given. In general, the residential market is by far the most promising market. The system discussed in this paper is expected to be most successful in newly-built low-energy housing concepts. (Author)

  20. Two Examples of Exergy Optimization Regarding the “Thermo-Frigopump” and Combined Heat and Power Systems

    Directory of Open Access Journals (Sweden)

    Michel Feidt

    2013-02-01

    Full Text Available In a recent review an optimal thermodynamics and associated new upper bounds have been proposed, but it was only relative to power delivered by engines. In fact, it appears that for systems and processes with more than one utility (mainly mechanical or electrical power, energy conservation (First Law is limited for representing their efficiency. Consequently, exergy analysis combining the First and Second Law seems essential for optimization of systems or processes situated in their environment. For thermomechanical systems recent papers report on comparisons between energy and exergy analysis and corresponding optimization, but the proposed models mainly use heat transfer conductance modelling, except for internal combustion engine. Here we propose to reconsider direct and inverse configurations of Carnot machines, with two examples. The first example is concerned with “thermofrigo-pump” where the two utilities are hot and cold thermal exergies due to the difference in the temperature level compared to the ambient one. The second one is relative to a “combined heat and power” (CHP system. In the two cases, the model is developed based on the Carnot approach, and use of the efficiency-NTU method to characterize the heat exchangers. Obtained results are original thermodynamics optima, that represent exergy upper bounds for these two cases. Extension of the proposed method to other systems and processes is examined, with added technical constraints or not.

  1. Generation and development of damage in double forged tungsten in different combined regimes of irradiation with extreme heat loads

    Science.gov (United States)

    Paju, Jana; Väli, Berit; Laas, Tõnu; Shirokova, Veroonika; Laas, Katrin; Paduch, Marian; Gribkov, Vladimir A.; Demina, Elena V.; Prusakova, Marina D.; Pimenov, Valeri N.; Makhlaj, Vadym A.; Antonov, Maksim

    2017-11-01

    Armour materials in fusion devices, especially in the region of divertor, are exposed to a continuous heat and particle load. In addition, several off-normal events can reach the material during a work session. Calculations show that the effects of plasma and heat during such events can lead to cracking, erosion and detachment of the armour material. On the other hand, mutual and combined influences of different kinds of heat and particle loads can lead to the amplification of defects or vice versa, to the mitigation of damages. Therefore, the purpose of the study is to investigate the plasma induced damages on samples of double forged tungsten, which is considered a potential candidate for armour material of future tokamak's divertor. The combined effect of different kinds of plasma induced damages was investigated and analysed in this research. The study was conducted by irradiating the samples in various irradiation regimes twice, to observe the accumulation of the damages. Afterwards the analysis of micro-topography, scanning electron microscopy images and electrical conductivity measurements was used. Results indicate that double-forging improved the tungsten's durability to irradiation. Nevertheless, powerful pulses lead to significant damage of the sample, which will lead to further deterioration in the bulk. Although the average micro-roughness on the sample's surface does not change, the overall height/depth ratios can change.

  2. Performance and costs of a roof-sized PV/thermal array combined with a ground coupled heat pump

    International Nuclear Information System (INIS)

    Bakker, M.; Zondag, H.A.; Elswijk, M.J.; Strootman, K.J.; Jong, M.J.M.

    2005-03-01

    A photovoltaic/thermal (PVT) panel is a combination of photovoltaic cells with a solar thermal collector, generating solar electricity and solar heat simultaneously. Hence, PVT panels are an alternative for a combination of separate PV panels and solar thermal collectors. A promising system concept, consisting of 25 m 2 of PVT panels and a ground coupled heat pump, has been simulated in TRNSYS. It has been found that this system is able to cover 100% of the total heat demand for a typical newly-built Dutch one-family dwelling, while covering nearly all of its own electricity use and keeping the long-term average ground temperature constant. The cost of such a system has been compared to the cost of a reference system, where the PVT panels have been replaced with separate PV panels (26 m 2 ) and solar thermal collectors (7 m 2 ), but which is otherwise identical. The electrical and thermal yield of this reference system is equal to that of the PVT system. It has been found that both systems require a nearly identical initial investment. Finally, a view on future PVT markets is given. In general, the residential market is by far the most promising market. The system discussed in this paper is expected to be most successful in newly-built low-energy housing concepts

  3. Life cycle analysis of distributed concentrating solar combined heat and power: economics, global warming potential and water

    Science.gov (United States)

    Norwood, Zack; Kammen, Daniel

    2012-12-01

    We report on life cycle assessment (LCA) of the economics, global warming potential and water (both for desalination and water use in operation) for a distributed concentrating solar combined heat and power (DCS-CHP) system. Detailed simulation of system performance across 1020 sites in the US combined with a sensible cost allocation scheme informs this LCA. We forecast a levelized cost of 0.25 kWh-1 electricity and 0.03 kWh-1 thermal, for a system with a life cycle global warming potential of ˜80 gCO2eq kWh-1 of electricity and ˜10 gCO2eq kWh-1 thermal, sited in Oakland, California. On the basis of the economics shown for air cooling, and the fact that any combined heat and power system reduces the need for cooling while at the same time boosting the overall solar efficiency of the system, DCS-CHP compares favorably to other electric power generation systems in terms of minimization of water use in the maintenance and operation of the plant. The outlook for water desalination coupled with distributed concentrating solar combined heat and power is less favorable. At a projected cost of 1.40 m-3, water desalination with DCS-CHP would be economical and practical only in areas where water is very scarce or moderately expensive, primarily available through the informal sector, and where contaminated or salt water is easily available as feed-water. It is also interesting to note that 0.40-1.90 m-3 is the range of water prices in the developed world, so DCS-CHP desalination systems could also be an economical solution there under some conditions.

  4. Combined natural convection and radiation from heated cylinders inside a container

    Science.gov (United States)

    Zhao, Z.; Poulikakos, D.; Ren, Z.

    1992-12-01

    In this article a numerical investigation verified by experiments is reported on steady-state heat transfer from three electrically heated cylinders equally spaced and resting at the bottom wall of a rectangular container. The investigation simulates heat transfer from power cables sparsely laid inside rectangular trays. The results indicate that a multicellular flow pattern existed in the system. At high Grashof numbers, the flow in the right half of the system consisted of a large cell rotating above the cylinders and two small cells trapped between the cylinders. Results for the average Nusselt number and the average and maximum temperature of the center cylinder are also reported in the present study. The average Nusselt number differs markedly from that for a single cylinder in an infinite space underlying the importance of the interaction of the cylinders with each other and with the container. The spacing of the cylinders had a visible effect on the magnitude and the location of the maximum temperature of the center cylinder.

  5. A dynamic regrouping based sequential dynamic programming algorithm for unit commitment of combined heat and power systems

    International Nuclear Information System (INIS)

    Rong, Aiying; Hakonen, Henri; Lahdelma, Risto

    2009-01-01

    This paper addresses the unit commitment (UC) in multi-period combined heat and power (CHP) production planning under the deregulated power market. In CHP plants (units), generation of heat and power follows joint characteristics, which implies that it is difficult to determine the relative cost efficiency of the plants. We introduce in this paper the DRDP-RSC algorithm, which is a dynamic regrouping based dynamic programming (DP) algorithm based on linear relaxation of the ON/OFF states of the units, sequential commitment of units in small groups. Relaxed states of the plants are used to reduce the dimension of the UC problem and dynamic regrouping is used to improve the solution quality. Numerical results based on real-life data sets show that this algorithm is efficient and optimal or near-optimal solutions with very small optimality gap are obtained

  6. Combined Heat and Power Systems Technology Development and Demonstration 370 kW High Efficiency Microturbine

    Energy Technology Data Exchange (ETDEWEB)

    none,

    2015-10-14

    The C370 Program was awarded in October 2010 with the ambitious goal of designing and testing the most electrically efficient recuperated microturbine engine at a rated power of less than 500 kW. The aggressive targets for electrical efficiency, emission regulatory compliance, and the estimated price point make the system state-of-the-art for microturbine engine systems. These goals will be met by designing a two stage microturbine engine identified as the low pressure spool and high pressure spool that are based on derivative hardware of Capstone’s current commercially available engines. The development and testing of the engine occurred in two phases. Phase I focused on developing a higher power and more efficient engine, that would become the low pressure spool which is based on Capstone’s C200 (200kW) engine architecture. Phase II integrated the low pressure spool created in Phase I with the high pressure spool, which is based on Capstone’s C65 (65 kW) commercially available engine. Integration of the engines, based on preliminary research, would allow the dual spool engine to provide electrical power in excess of 370 kW, with electrical efficiency approaching 42%. If both of these targets were met coupled with the overall CHP target of 85% total combined heating and electrical efficiency California Air Resources Board (CARB) level emissions, and a price target of $600 per kW, the system would represent a step change in the currently available commercial generation technology. Phase I of the C370 program required the development of the C370 low pressure spool. The goal was to increase the C200 engine power by a minimum of 25% — 250 kW — and efficiency from 32% to 37%. These increases in the C200 engine output were imperative to meet the power requirements of the engine when both spools were integrated. An additional benefit of designing and testing the C370 low pressure spool was the possibility of developing a stand-alone product for possible

  7. An assessment of the present and future opportunities for combined heat and power with district heating (CHP-DH) in the United Kingdom

    International Nuclear Information System (INIS)

    Kelly, Scott; Pollitt, Michael

    2010-01-01

    As global fuel reserves are depleted, alternative and more efficient forms of energy generation and delivery will be required. Combined heat and power with district heating (CHP-DH) provides an alternative energy production and delivery mechanism that is less resource intensive, more efficient and provides greater energy security than many popular alternatives. It will be shown that the economic viability of CHP-DH networks depends on several principles, namely (1) the optimisation of engineering and design principles; (2) organisational and regulatory frameworks; (3) financial and economic factors. It was found that in the long term DH is competitive with other energy supply and distribution technologies such as electricity and gas. However, in the short to medium term it is shown that economic risk, regulatory uncertainty and lock-in of existing technology are the most significant barriers to CHP-DH development. This research suggests that under the present regulatory and economic paradigm, the infrastructure required for DH networks remains financially prohibitive; the implementation of government policies are complicated and impose high transaction costs, while engineering solutions are frequently not implemented or economically optimised. If CHP-DH is going to play any part in meeting climate change targets then collaboration between public and private organisations will be required. It is clear from this analysis that strong local government involvement is therefore necessary for the co-ordination, leadership and infrastructural deployment of CHP-DH.

  8. Technologies for small scale wood-fueled combined heat and power systems

    Energy Technology Data Exchange (ETDEWEB)

    Houmann Jakobsen, H.; Houmoeller, S.; Thaaning Pedersen, L.

    1998-01-01

    The aim of this study is to describe and compare different technologies for small cogeneration systems (up to 2-3 MW{sub e}), based on wood as fuel. For decentralized cogeneration, i.e. for recovering energy from saw mill wood wastes or heat supply for small villages, it is vital to know the advantages and disadvantages of the different technologies. Also, for the decision-makers it is of importance to know the price levels of the different technologies. A typical obstacle for small wood cogeneration systems is the installation costs. The specific price (per kW) is usually higher than for larger plants or plants using fossil fuels. For a saw mill choosing between cogeneration and simple heat production, however, the larger installation costs are counter weighed by the sale of electricity, while the fuel consumption is the same. Whether it is profitable or not to invest in cogeneration is often hard to decide. For many years small wood cogeneration systems have been too expensive, leading to the construction of only heat producing systems due to too high price levels of small steam turbines. In recent years a great deal of effort has been put into research and developing of new technologies to replace this traditional steam turbine. Among these are: Steam engines; Stirling engines; Indirectly fired gas turbines; Pressurized down draft combustion. Along with the small scale traditional steam turbines, these technologies will be evaluated in this study. When some or all these technologies are fully developed and commercial, a strong means of reducing the strain on the environment and the greenhouse effect will be available, as the total efficiency is high (up to 90%) and wood is an energy source in balance with nature. (au) EFP-95. 19 refs.

  9. Dual capillary tube / heat exchanger in combination with cycle priming for reducing charge migration

    Science.gov (United States)

    Gomes, Alberto Regio; Kuehl, Steven J.; Litch, Andrew D.; Wu, Guolian

    2017-07-04

    A refrigerator appliance including a multi-capacity compressor and a refrigerant circuit with two conduits and pressure reducing devices arranged in parallel between an evaporator and a condenser. Refrigerant can flow through one, both or none of the conduits and pressure reducing devices. The appliance also has a heat exchanger in contact with either one pressure reducing device, or one conduit between the pressure reducing device and the valve system. The appliance also includes a controller for priming the compressor above a nominal capacity for a predetermined or calculated duration at the beginning of an ON-cycle.

  10. Support schemes and ownership structures - The policy context for fuel cell based micro-combined heat and power

    Energy Technology Data Exchange (ETDEWEB)

    Ropenus, S.; Thorsten Schroeder, S.; Costa, A.; Obe, E.

    2010-05-15

    In recent years, fuel cell based micro-combined heat and power has received increasing attention due to its potential contribution to energy savings, efficiency gains, customer proximity and flexibility in operation and capacity size. The FC4Home project assesses technical and economic aspects of the ongoing fuel cell based micro-combined heat and power (mCHP) demonstration projects by addressing the socio-economic and systems analyses perspectives of a large-scale promotion scheme of fuel cells. This document constitutes the deliverable of Work Package 1 of the FC4Home project and provides an introduction to the policy context for mCHP. Section 1 describes the rationale for the promotion of mCHP by explaining its potential contribution to European energy policy goals. Section 2 addresses the policy context at the supranational European level by outlining relevant EU Directives on support schemes for promoting combined heat and power and energy from renewable sources. These Directives are to be implemented at the national level by the Member States. Section 3 conceptually presents the spectrum of national support schemes, ranging from investment support to market-based operational support. The choice of support scheme simultaneously affects risk and technological development, which is the focus of Section 4. Subsequent to this conceptual overview, Section 5 takes a glance at the national application of support schemes for mCHP in practice, notably in the three country cases of the FC4Home project, Denmark, France and Portugal. Another crucial aspect for the diffusion of the mCHP technology is possible ownership structures. These may range from full consumer ownership to ownership by utilities and energy service companies, which is discussed in Section 6. Finally, a conclusion (Section 7) wraps up previous findings and provides a short 'preview' of the quantitative analyses in subsequent Work Packages by giving some food for thought on the way. (author)

  11. Involvement of ascorbate peroxidase and heat shock proteins on citrus tolerance to combined conditions of drought and high temperatures.

    Science.gov (United States)

    Balfagón, Damián; Zandalinas, Sara I; Baliño, Pablo; Muriach, María; Gómez-Cadenas, Aurelio

    2018-03-27

    Usually several environmental stresses occur in nature simultaneously causing a unique plant response. However, most of the studies until now have focused in individually-applied abiotic stress conditions. Carrizo citrange (Poncirus trifoliata L. Raf. X Citrus sinensis L. Osb.) and Cleopatra mandarin (Citrus reshni Hort. ex Tan.) are two citrus rootstocks with contrasting tolerance to drought and heat stress and have been used in this work as a model for the study of plant tolerance to the combination of drought and high temperatures. According to our results, leaf integrity and photosynthetic machinery are less affected in Carrizo than in Cleopatra under combined conditions of drought and heat stress. The pattern of accumulation of three proteins (APX, HSP101 and HSP17.6) involved in abiotic stress tolerance shows that they do not accumulate under water stress conditions individually applied. However, contents of APX and HSP101 are higher in Carrizo than in Cleopatra under stress combination whereas HSP17.6 has a similar behavior in both types of plants. This, together with a better stomatal control and a higher APX activity of Carrizo, contributes to the higher tolerance of Carrizo plants to the combination of stresses and point to it as a better rootstock than Cleopatra (traditionally used in areas with scare water supplies) under the predictable future climatic conditions with frequent periods of drought combined with high temperatures. This work also provides the basis for testing the tolerance of different citrus varieties grafted on these rootstocks and growing under different field conditions. Copyright © 2018 Elsevier Masson SAS. All rights reserved.

  12. Impact of heat stress, nutritional restriction and combined stresses (heat and nutritional) on growth and reproductive performance of Malpura rams under semi-arid tropical environment.

    Science.gov (United States)

    Maurya, V P; Sejian, V; Kumar, D; Naqvi, S M K

    2016-10-01

    A study was conducted to assess the combined effect of heat stress and nutritional restriction on growth and reproductive performances in Malpura rams. Twenty-eight adult Malpura rams (average body weight (BW) 66.0 kg) were used in this study. The rams were divided into four groups: CON (n = 7; control), HES (n = 7; heat stress), NUS (n = 7; nutritional stress) and COS (n = 7; combined stress). The study was conducted for a period of 2 months. CON and HES rams had ad libitum access to their feed while NUS and COS rams were under restricted feed (30% intake of CON rams) to induce nutritional stress. The HES and COS rams were kept in climatic chamber at 42 °C and 55% relative humidity for 6 h a day between 10 : 00 h and 16 : 00 h to induce heat stress. Body weight increased significantly (p < 0.05) in CON as compared to NUS and COS. When compared within groups, scrotal width morning, scrotal width afternoon, scrotal circumference morning and scrotal circumference afternoon were significantly (p < 0.05) larger in CON while smaller in COS rams. The higher testicular length was recorded both during morning (p < 0.05) and afternoon (p < 0.01) in COS rams while the lowest in NUS rams. The highest plasma testosterone concentration was recorded in CON and lowest in COS rams. Semen volume and mass motility also differed significantly (p < 0.05) between the groups. The highest semen volume and mass motility was recorded in CON and NUS while lowest in both HES and COS rams. It can be concluded from this study that when two stressors occur simultaneously, they may have severe impact on reproductive performance of rams. Journal of Animal Physiology and Animal Nutrition © 2015 Blackwell Verlag GmbH.

  13. Decentralized combined heat and power production by two-stage biomass gasification and solid oxide fuel cells

    DEFF Research Database (Denmark)

    Bang-Møller, Christian; Rokni, Masoud; Elmegaard, Brian

    2013-01-01

    To investigate options for increasing the electrical efficiency of decentralized combined heat and power (CHP) plants fuelled with biomass compared to conventional technology, this research explored the performance of an alternative plant design based on thermal biomass gasification and solid oxide......, carbon conversion factor in the gasifier and the efficiency of the DC/AC inverter were the most influential parameters in the model. Thus, a detailed study of the practical values of these parameters was conducted to determine the performance of the plant with the lowest possible uncertainty. The SOFC...

  14. Combined coal gasification and Fe{sub 3}O{sub 4}-reduction using high-temperature solar process heat

    Energy Technology Data Exchange (ETDEWEB)

    Tamaura, Y. [Tokyo Inst. of Technology, Tokyo (Japan); Ehrensberger, K.; Steinfeld, A. [Paul Scherrer Inst. (PSI), Villigen (Switzerland)

    1997-06-01

    The coal/Fe{sub 3}O{sub 4} system was experimentally studied at PSI solar furnace. The reactants were directly exposed to a solar flux irradiation of 3,000 suns (1 sun = 1 kW/m{sup 2}). The combined gasification of coal and reduction of Fe{sub 2}O{sub 3} proceeded rapidly after only one second exposure, suggesting an efficient heat transfer and chemical conversion by direct solar energy absorption at the reaction site. The proposed solar thermochemical process offers the possibility of converting coal to a cleaner fluid fuel with a solar-upgraded calorific value. (author) 2 figs., 8 refs.

  15. Drying grain residual annatto by sun combined with drying in dryer with heat accumulator

    Directory of Open Access Journals (Sweden)

    Dyego da Costa Santos

    2014-02-01

    Full Text Available The process of extraction of the pigment bixin results in a large amount of residual grain annatto. Most of this material is discarded, but you can enjoy it by incorporating it into animal feed and human food. This study aimed to dry grain residual annatto using solar energy. The beans were divided into two batches, one with oil, reproducing conditions of the grains after extraction of bixin oil, and other oil-free. The drying was performed during the day in the concrete base covered with black polythene bag with samples in trays and exposed to the sun; overnight half of the samples was placed in a dryer to dry heat accumulator and the other half was in bench laboratory for control. The grains showed levels of initial and final moisture of about 18% wb and 5% wb, respectively. Use the dryer heat accumulator at night allowed the collection of samples with the moisture ratio below 0.1 in the evening of the first day of drying, while the control samples absorbed water during the night. All models studied showed good fit to experimental data, with values of determination coefficients above 0.95 and average values of the squared deviations of less than 0.1. The diffusivity coefficients were of the order of 10-9 m2 s-1 for all treatments, with the grain samples without oil showing the greatest value.

  16. Combined laser ultrasonics, laser heating, and Raman scattering in diamond anvil cell system

    Science.gov (United States)

    Zinin, Pavel V.; Prakapenka, Vitali B.; Burgess, Katherine; Odake, Shoko; Chigarev, Nikolay; Sharma, Shiv K.

    2016-12-01

    We developed a multi-functional in situ measurement system under high pressure equipped with a laser ultrasonics (LU) system, Raman device, and laser heating system (LU-LH) in a diamond anvil cell (DAC). The system consists of four components: (1) a LU-DAC system (probe and pump lasers, photodetector, and oscilloscope) and DAC; (2) a fiber laser, which is designed to allow precise control of the total power in the range from 2 to 100 W by changing the diode current, for heating samples; (3) a spectrometer for measuring the temperature of the sample (using black body radiation), fluorescence spectrum (spectrum of the ruby for pressure measurement), and Raman scattering measurements inside a DAC under high pressure and high temperature (HPHT) conditions; and (4) an optical system to focus laser beams on the sample and image it in the DAC. The system is unique and allows us to do the following: (a) measure the shear and longitudinal velocities of non-transparent materials under HPHT; (b) measure temperature in a DAC under HPHT conditions using Planck's law; (c) measure pressure in a DAC using a Raman signal; and (d) measure acoustical properties of small flat specimens removed from the DAC after HPHT treatment. In this report, we demonstrate that the LU-LH-DAC system allows measurements of velocities of the skimming waves in iron at 2580 K and 22 GPa.

  17. Themoeconomic optimization of triple pressure heat recovery steam generator operating parameters for combined cycle plants

    Directory of Open Access Journals (Sweden)

    Mohammd Mohammed S.

    2015-01-01

    Full Text Available The aim of this work is to develop a method for optimization of operating parameters of a triple pressure heat recovery steam generator. Two types of optimization: (a thermodynamic and (b thermoeconomic were preformed. The purpose of the thermodynamic optimization is to maximize the efficiency of the plant. The selected objective for this purpose is minimization of the exergy destruction in the heat recovery steam generator (HRSG. The purpose of the thermoeconomic optimization is to decrease the production cost of electricity. Here, the total annual cost of HRSG, defined as a sum of annual values of the capital costs and the cost of the exergy destruction, is selected as the objective function. The optimal values of the most influencing variables are obtained by minimizing the objective function while satisfying a group of constraints. The optimization algorithm is developed and tested on a case of CCGT plant with complex configuration. Six operating parameters were subject of optimization: pressures and pinch point temperatures of every three (high, intermediate and low pressure steam stream in the HRSG. The influence of these variables on the objective function and production cost are investigated in detail. The differences between results of thermodynamic and the thermoeconomic optimization are discussed.

  18. Optimised heat recovery steam generators for integrated solar combined cycle plants

    Science.gov (United States)

    Peterseim, Jürgen H.; Huschka, Karsten

    2017-06-01

    The cost of concentrating solar power (CSP) plants is decreasing but, due to the cost differences and the currently limited value of energy storage, implementation of new facilities is still slow compared to photovoltaic systems. One recognized option to lower cost instantly is the hybridization of CSP with other energy sources, such as natural gas or biomass. Various references exist for the combination of CSP with natural gas in combined cycle plants, also known as Integrated Solar Combined Cycle (ISCC) plants. One problem with current ISCC concepts is the so called ISCC crisis, which occurs when CSP is not contributing and cycle efficiency falls below efficiency levels of solely natural gas only fired combined cycle plants. This paper analyses current ISCC concepts and compares them with two optimised designs. The comparison is based on a Kuraymat type ISCC plant and shows that cycle optimization enables a net capacity increase of 1.4% and additional daily generation of up to 7.9%. The specific investment of the optimised Integrated Solar Combined Cycle plant results in a 0.4% cost increase, which is below the additional net capacity and daily generation increase.

  19. Evaluation of gross radioactivity in foodstuffs

    Energy Technology Data Exchange (ETDEWEB)

    Zorer, Oezlem Selcuk; Oeter, Cigdem [Yuzuncu Yil Univ., Van (Turkey). Dept. of Chemistry

    2015-05-15

    The paper presents the results of radiological investigations of food products sampled in the summer and fall of 2011 and 2012 in different parts of Van, Turkey. Gross radioactivity measurements in food products were evaluated. Food items were divided into eight groups: (1) water, (2) fish, (3) cheese products, (4) fruits, (5) vegetables, (6) herbs, (7) walnut and (8) rock salt. The levels of the gross alpha and gross beta radioactivity in all food samples varied widely ranging from 0.070 to 10.885 Bq/g and from 0.132 to 48.285 Bq/g on dry mass basis, respectively. In one sample, gross alpha and gross beta activity concentrations were found to be relatively high according to the other samples and in all samples, the gross alpha radioactivity was measured lower than the gross beta radioactivity. The gross α and gross β activities were measured by using α/β counter of the multi-detector low background system (PIC MPC-9604).

  20. Effect of sanitizer combined with steam heating on the inactivation of foodborne pathogens in a biofilm on stainless steel.

    Science.gov (United States)

    Ban, Ga-Hee; Kang, Dong-Hyun

    2016-05-01

    The combined effect of chemical sanitizers including sodium hypochlorite, hydrogen peroxide, iodophor, and benzalkonium chloride with steam heating on the inactivation of biofilms formed by Escherichia coli O157:H7, Salmonella Typhimurium, and Listeria monocytogenes on stainless steel was investigated. Six day old biofilms, comprised of a mixture of three strains each of three foodborne pathogens, were produced on stainless steel coupons at 25 °C and treated with each sanitizer alone (for 5, 15, and 30 s), steam alone (for 5, 10, and 20 s), and the combination. There was a synergistic effect of sanitizer and steam on the viability of biofilm cells of the three pathogens as evidenced by plating counts and imaging. The combination treatment achieved an additional 0.01 to 2.78 log reduction compared to the sum of each individual treatment. The most effective combination for reducing levels of biofilm cells was the combination of steam and iodophor; steam for 20 s and merely 20 ppm iodophor for 30 s reduced cell numbers to below the detection limit (sanitizer with steam can be applied to control foodborne pathogens biofilm cells in food processing facilities as a potential intervention. Copyright © 2015 Elsevier Ltd. All rights reserved.

  1. Radiosensitization of tumors and normal tissues by combined treatment with misonidazole and heat

    International Nuclear Information System (INIS)

    Hofer, K.G.; MacKinnon, A.R.; Schubert, A.L.; Lehr, J.E.; Grimmett, E.V.

    1981-01-01

    Combination treatment of mice with misonidazole (0.5 mg/g body wt.) and hyperthermia (41.5/sup o/C for 45 mins.) produced dramatic radiosensitization in hypoxic BP-8 murine sarcoma cells. The dose modifying factor (DMF: 4.3) was such that hypoxic BP-8 cells subjected to combination therapy became more radiosensitive than untreated, fully oxygenated cell populations. In contrast, radiosensitization by combination treatment was comparatively minor or completely absent in normal body tissues such as skin (DMF: 1.57), intestine (DMF: 1.0), and bone marrow (DMF: 1.0). These results suggest that simultaneous administration of misonidazole and hyperthermia may prove an effective adjuvant to conventional clinical radiation therapy

  2. Combined heat and power production by biofuels, regional survey; Saehkoen ja laemmoen yhteistuotanto biopolttoaineilla, alueellinen selvitys. Tutkimusraportti

    Energy Technology Data Exchange (ETDEWEB)

    Lehtovaara, M. (ed.)

    2011-07-01

    The scarcity of primary energy sources and Global warming mainly due to increased amount of greenhouse gases are becoming serious environmental concerns. Decentralized small-scale combined heat and power production (CHP) using biofuels such as woodchips could offer a qualified, sustainable solution for this concern. In this regional survey, market potential for small-scale CHP-technology was studied. Further, local primary bioenergy sources were investigated as well as heating plant entrepreneurs and manufacturers capable of supplying also power generation units in the future. Based on the basic results potential CHP-technology users were consulted by preliminary feasibility studies. The results reveal that biofueled small-scale CHP-technology using microturbines or Stirling-engines for power production is still in the early stages of development. The feasibility studies showed that the cases are unique, and the most lucrative are farms, garden houses or real estate that have relatively high and constant need of heat and power. Feed-in tariffs and other subsidies alone do not guarantee the feasibility of CHP-investment. (orig.)

  3. Techno-economic Assessment of Integrated Hydrothermal Liquefaction and Combined Heat and Power Production from Lignocellulose Residues

    Directory of Open Access Journals (Sweden)

    Mohamed Magdeldin

    2018-03-01

    Full Text Available Waste biomass as a mean for global carbon dioxide emissions mitigation remains under-utilized. This is mainly due to the low calorific value of virgin feedstock, characterized generally with high moisture content. Aqueous processing, namely hydrothermal liquefaction in subcritical water conditions, has been demonstrated experimentally to thermally densify solid lignocellulose into liquid fuels without the pre-requisite and energy consuming drying step. This study presents a techno-economic evaluation of an integrated hydrothermal liquefaction system with downstream combined heat and power production from forest residues. The utilization of the liquefaction by-products and waste heat from the elevated processing conditions, coupled with the chemical upgrading of the feedstock enables the poly-generation of biocrude, electricity and district heat. The plant thermal efficiency increases by 3.5 to 4.6% compared to the conventional direct combustion case. The economic assessment showed that the minimum selling price of biocrude, based on present co-products market prices, hinders commercialization and ranges between 138 EUR to 178 EUR per MWh. A sensitivity analysis and detailed discussion on the techno-economic assessment results are presented for the different process integration and market case scenarios.

  4. The combined simulation of heat transfer and pyrolysis reactions in industrial cracking furnaces

    Energy Technology Data Exchange (ETDEWEB)

    Niaei, A. [Tabriz University, Tehran (Iran). Chemical Engineering Dept.; Towfighi, J.; Sadrameli, S.M.; Karimzadeh, R. [Tarbiat Modarres University, Tehran (Iran). Chemical Engineering Dept.

    2004-10-01

    Thermal cracking of hydrocarbons for olefins production is carried out in large, gas fired furnaces containing parallel reactor coils. The simulation of these coils requires detailed kinetics, based upon radical reaction schemes and a rigorous description of heat transfer in the firebox. A complete modeling of the reactor and the firebox, using a rigorous kinetic model, for the pyrolysis of naphtha has been developed and is used here for the simulation of naphtha crackers. The coupled simulation of the reactor and the radiant box by means of the zone method, results in the understanding of the behavior of the furnace. The simulation results are in good agreement with the experimental data. The model and computational scheme can be used as a guide for plant operators and as a tool for design. (author)

  5. Expert Meeting Report. Recommendations for Applying Water Heaters in Combination Space and Domestic Water Heating Systems

    Energy Technology Data Exchange (ETDEWEB)

    Rudd, A. [Building Science Corporation (BSC), Somerville, MA (United States); Ueno, K. [Building Science Corporation (BSC), Somerville, MA (United States); Bergey, D. [Building Science Corporation (BSC), Somerville, MA (United States); Osser, R. [Building Science Corporation (BSC), Somerville, MA (United States)

    2012-06-01

    This Building America expert meeting was held on 7/31/2011, in Westford, Massachusetts. Presentations and discussions centered on the design, performance, and maintenance of these combination systems, with the goal of developing foundational information toward the development of a Building America Measure Guideline on this topic.

  6. Technical and economical analyses of combined heat and power generation from distillers grains and corn stover in ethanol plants

    International Nuclear Information System (INIS)

    Wang Lijun; Hanna, Milford A.; Weller, Curtis L.; Jones, David D.

    2009-01-01

    The technical and economical feasibilities of a novel integrated biomass gasification and fuel cell combined heat and power (CHP) system were analyzed for supplying heat and power in an ethanol plant from distillers grains (DG) and corn stover. In a current dry-grind plant with an annual production capacity of 189 million liters (50 million gallons) of ethanol, the energy cost for ethanol production using natural gas at a price of 6.47 US$/GJ for processing heat and commercial grid at a price of 0.062 US$/kWh for electrical power supply was 0.094 US$/liter. If the integrated CHP system using wet DG with 64.7% moisture on a wet basis at 105 US$/dry tonne and corn stover with 20% moisture at 30 US$/dry tonne as feedstock was used to supply heat and power in the ethanol plant, the energy costs for ethanol production would be 0.101 US$/liter and 0.070 US$/liter, which are 107% and 75% of the current energy cost for ethanol production, respectively. To meet the demand of processing heat and power in the ethanol plant, the integrated CHP system required 22.1 dry tonnes of corn stover with 20% moisture or 14.5 dry tonnes of DG with 64.7% moisture on a wet basis per hour, compared with the available 18.8 dry tonnes of DG per hour in the ethanol plant. High-value chemicals such as policosanols, phytosterols and free fatty acids can be extracted out of the raw DG to reduce the cost of DG as a feedstock of the integrated CHP system. The energy cost for ethanol production using the integrated CHP system with corn stover and DG as the feedstock for supplying heat and power can be reduced further by increasing ethanol production scale, decreasing the moisture content of biomass feedstock, and decreasing thermal energy to electricity output ratio of the CHP system. In terms of the energy efficiency of the integrated CHP system and the energy cost for ethanol production, the moisture content of the feedstock going into the integrated CHP should be lower than 70% on a wet basis.

  7. Performance analysis of a bio-gasification based combined cycle power plant employing indirectly heated humid air turbine

    Energy Technology Data Exchange (ETDEWEB)

    Mukherjee, S., E-mail: sankha.deepp@gmail.com; Mondal, P., E-mail: mondal.pradip87@gmail.com; Ghosh, S., E-mail: sudipghosh.becollege@gmail.com [Department of Mechanical Engineering, Indian Institute of Engineering Science and Technology, Shibpur, Howrah – 711103, West Bengal (India)

    2016-07-12

    Rapid depletion of fossil fuel has forced mankind to look into alternative fuel resources. In this context, biomass based power generation employing gas turbine appears to be a popular choice. Bio-gasification based combined cycle provides a feasible solution as far as grid-independent power generation is concerned for rural electrification projects. Indirectly heated gas turbine cycles are promising alternatives as they avoid downstream gas cleaning systems. Advanced thermodynamic cycles have become an interesting area of study to improve plant efficiency. Water injected system is one of the most attractive options in this field of applications. This paper presents a theoretical model of a biomass gasification based combined cycle that employs an indirectly heated humid air turbine (HAT) in the topping cycle. Maximum overall electrical efficiency is found to be around 41%. Gas turbine specific air consumption by mass is minimum when pressure ratio is 6. The study reveals that, incorporation of the humidification process helps to improve the overall performance of the plant.

  8. Thermo-economic analysis and optimization of a combined cooling and power (CCP) system for engine waste heat recovery

    International Nuclear Information System (INIS)

    Xia, Jiaxi; Wang, Jiangfeng; Lou, Juwei; Zhao, Pan; Dai, Yiping

    2016-01-01

    Highlights: • A combined cooling and power system was proposed for engine waste heat recovery. • Effects of key parameters on thermodynamic performance of the system were studied. • Exergoeconomic parameter analysis was performed for the system. • A single-objective optimization by means of genetic algorithm was carried out. - Abstract: A combined cooling and power (CCP) system is developed, which comprises a CO 2 Brayton cycle (BC), an organic Rankine cycle (ORC) and an ejector refrigeration cycle for the cascade utilization of waste heat from an internal combustion engine. By establishing mathematical model to simulate the overall system, thermodynamic analysis and exergoeconomic analysis are conducted to examine the effects of five key parameters including the compressor pressure ratio, the compressor inlet temperature, the BC turbine inlet temperature, the ORC turbine inlet pressure and the ejector primary flow pressure on system performance. What’s more, a single-objective optimization by means of genetic algorithm (GA) is carried out to search the optimal system performance from viewpoint of exergoeconomic. Results show that the increases of the BC turbine inlet temperature, the ORC turbine inlet pressure and the ejector primary flow pressure are benefit to both thermodynamic and exergoeconimic performances of the CCP system. However, the rises in compressor pressure ratio and compressor inlet temperature will lead to worse system performances. By the single-objective optimization, the lowest average cost per unit of exergy product for the overall system is obtained.

  9. Thermodynamic analysis of a Kalina-based combined cooling and power cycle driven by low-grade heat source

    International Nuclear Information System (INIS)

    Cao, Liyan; Wang, Jiangfeng; Wang, Hongyang; Zhao, Pan; Dai, Yiping

    2017-01-01

    Highlights: • A Kalina-based combined cooling and power cycle is proposed to recover low-grade heat source. • The effects of several parameters on cycle performance are examined. • An optimization is conducted by GA to obtain optimum performance. - Abstract: This paper investigates a Kalina-based combined cooling and power (CCP) cycle driven by low-grade heat source. The proposed cycle consists of a Kalina cycle and an absorption refrigeration cycle. By establishing the mathematical model, numerical simulation is conducted and parametric analysis is performed to examine the effects of five key parameters on the thermodynamic performances of Kalina-based CCP cycle. A performance optimization is conducted by genetic algorithm to obtain the optimum exergy efficiency. According to parametric analysis, an optimum expander inlet pressure can be achieved; exergy efficiency increases with expander inlet pressure and concentration of ammonia-water basic solution, but exergy efficiency decreases when terminal temperature difference of high-temperature recuperator and low-temperature recuperator increases. Refrigeration exergy increases with expander inlet pressure and decreases as expander inlet temperature and concentration of ammonia-water basic solution rise. However, the refrigeration exergy keeps constant as the terminal temperature difference of high-temperature recuperator and low-temperature recuperator vary. Furthermore, the optimized Kalina-based CCP cycle is compared with a separate generation system which is also optimized. The optimization results show that the exergy efficiency and net power output of Kalina-based CCP are higher than those of separate generation system.

  10. Exergoenvironmental optimization of Heat Recovery Steam Generators in combined cycle power plant through energy and exergy analysis

    International Nuclear Information System (INIS)

    Kaviri, Abdolsaeid Ganjeh; Jaafar, Mohammad Nazri Mohd.; Lazim, Tholudin Mat; Barzegaravval, Hassan

    2013-01-01

    Highlights: ► Comprehensive thermodynamic modeling of a heat recovery steam generator used in CCPP. ► To conduct exergy analysis to find the location of reversibility. ► To increase the system performance using optimization. ► Better performance assessment of the system. - Abstract: Combined cycle power plants (CCPPs) are preferred technology for electricity generation due to less emission and high efficiency. These cycles are made of a gas turbine, a steam turbine and Heat Recovery Steam Generator (HRSG). In the present research study, a combined cycle power plant with dual pressure and supplementary firing is selected. The optimum design procedure included designing objective function, exergy destruction per unit of inlet gas to the HRSG subject to a list of constraints. The design parameters (design variables) were drum pressure and pinch temperature difference as well as steam mass flow of HRSG high and low pressure levels. The influence of HRSG inlet gas temperature on the steam cycle efficiency is discussed. The result show increasing HRSG inlet gas temperature until 650 °C leads to increase the thermal efficiency and exergy efficiency of the cycle and after that has less improvement and start to decrease them. And also from the exergy analysis of each part of HRSG, it is cleared that the HP-EV and 2st HP-SH have the most exergy destruction respectively. In other hand, effects of HRSG inlet gas temperature on SI (sustainability index) and CO 2 emission are considered

  11. The combined effect of gamma radiation and heat on some biological aspects of onion bulb fly Eumerus amoenus Loew

    International Nuclear Information System (INIS)

    El-Orabi, M.N.; Gharieb, O.H.; Hamza, A.F.H.; El-Saeadi, A.A.; Hussain, A.E.

    2010-01-01

    The effect of sub-sterilizing doses of gamma radiation, in combination with three degrees of temperature (20, 25 and 30 degree C). on some biological parameters of Eumerus Amoenus Loew were studied. The combined effect of radiation and heat were carried out on developmental stages namely; larval, pupal stages. Larval duration decreased significantly by increasing rearing temperature and increased by raising heat regardless larval instar. The same trend was observed in percent pupation, percent emergence. Irradiation of larvae decreases the adult emergence percentage under all temperatures. The results indicate that no adult male emergence when irradiated 4-d-old larvae at all doses when kept at 20 and 25 degree C. life-span of adults emerged from pupae irradiated as 5 and 7 day-old with sterilizing and sub-sterilizing doses was affected depending upon the dose level, temperatures and age of pupae at the time of irradiation. Fecundity of a female decreased by decreasing temperature degree or increasing radiation dose. Also, fertility of males decreased by radiation dose and by mating to irradiated females, this decrease was increased by increasing age of male and by decreasing temperature

  12. Biomass from agriculture in small-scale combined heat and power plants - A comparative life cycle assessment

    International Nuclear Information System (INIS)

    Kimming, M.; Sundberg, C.; Nordberg, A.; Baky, A.; Bernesson, S.; Noren, O.; Hansson, P.-A.

    2011-01-01

    Biomass produced on farm land is a renewable fuel that can prove suitable for small-scale combined heat and power (CHP) plants in rural areas. However, it can still be questioned if biomass-based energy generation is a good environmental choice with regards to the impact on greenhouse gas emissions, and if there are negative consequences of using of agricultural land for other purposes than food production. In this study, a simplified life cycle assessment (LCA) was conducted over four scenarios for supply of the entire demand of power and heat of a rural village. Three of the scenarios are based on utilization of biomass in 100 kW (e) combined heat and power (CHP) systems and the fourth is based on fossil fuel in a large-scale plant. The biomass systems analyzed were based on 1) biogas production with ley as substrate and the biogas combusted in a microturbine, 2) gasification of willow chips and the product gas combusted in an IC-engine and 3) combustion of willow chips for a Stirling engine. The two first scenarios also require a straw boiler. The results show that the biomass-based scenarios reduce greenhouse gas emissions considerably compared to the scenario based on fossil fuel, but have higher acidifying emissions. Scenario 1 has by far the best performance with respect to global warming potential and the advantage of utilizing a byproduct and thus not occupying extra land. Scenario 2 and 3 require less primary energy and less fossil energy input than 1, but set-aside land for willow production must be available. The low electric efficiency of scenario 3 makes it an unsuitable option.

  13. Swiss energy research program on heat-pumps, combined heat and power and refrigeration for 2008-2011; Energieforschungsprogramm. Waermepumpen, Waerme-Kraft-Kopplung, Kaelte fuer die Jahre 2008-2011

    Energy Technology Data Exchange (ETDEWEB)

    Kopp, T. [Hochschule fuer Technik HSR, Rapperswil (Switzerland); Eckmanns, A. [Swiss Federal Office of Energy (OFEN), Berne (Switzerland)

    2009-07-15

    This report published by the Swiss Federal Office of Energy (SFOE) takes a look at the research programme on heat-pumps, combined heat and power and refrigeration for the years 2008 - 2011. Work proposed for the years 2008 - 2011 involves the following topics: Improvement of components and the thermodynamic cycles of heat pumps and refrigeration plants as well as the improvements in the efficiency of cogeneration plants and the reduction of emission of pollutants. Also, the overall optimisation of total systems is to be examined. Highly-efficient systems for sanitary hot water production are to be looked at, as are miniaturisation and new solutions for the installation of heating and cooling systems with heat pumps. Also the development of environmental-friendly working fluids for heat pumps and refrigeration plants is planned. Pilot and demonstration projects are also to be supported in all areas.

  14. Alternative Measure of Wellbeing: Bhutan's Gross National ...

    International Development Research Centre (IDRC) Digital Library (Canada)

    There is growing demand for innovative yet rigorous measures of national wellbeing beyond gross domestic product. In 2008, the Centre for Bhutan Studies - Bhutan's main policy research centre - posted data from a preliminary survey of the country's Gross National Happiness (GNH). The Centre for Bhutan Studies ...

  15. Validating the Rett Syndrome Gross Motor Scale

    DEFF Research Database (Denmark)

    Downs, Jenny; Stahlhut, Michelle; Wong, Kingsley

    2016-01-01

    the validity and reliability of the Rett Syndrome Gross Motor Scale. Video data showing gross motor abilities supplemented with parent report data was collected for 255 girls and women registered with the Australian Rett Syndrome Database, and the factor structure and relationships between motor scores, age...

  16. CHP: Combined Heat and Power: a vision of energy efficiency; Cogeracao: uma visao de eficiencia energetica

    Energy Technology Data Exchange (ETDEWEB)

    Andrade, Osvaldo A.S.N. de; Abreu, Melissa E. de; Marcal, Roberto L.; Ferreira, Ademilson D.; Ferreira, Patricia E.; Monterio, Glauber J.R.; Silva, Ademir B. [PETROBRAS, Rio de Janeiro, RJ (Brazil)

    2008-07-01

    The installation of a cogeneration plant has been the subject of discussions on alternatives in the Brazilian energy matrix. Considered viable solution in the not too distant past, 2001, when Brazil was undergoing a process of the economic slowdown, lack of investments in the energy sector, unemployment and reaching the peak of the crisis with the rationing of electricity. The principle of the cogeneration system is designed primarily to meet electrical demand, so there is no surplus production of energy and do not need to buy with the concessionaire, except in cases of the system stops on account of maintenance. However, there is a recovery of waste heat produced in thermodynamic processes for generation of electricity within a model that 'conventional' would be wasted. In this case, the exploitation can be given in the form of steam, hot water and/or cold, for secondary application, or can not be linked to a process. Based on the results of the fieldwork, aims to show that, despite the limitations inherent in the process of cogeneration, is justified economically the installation of this system in relation to the growth of procedures developed in CENPES and its resident effective. (author)

  17. Combined bio and solar heating system. Handbook for system design; Kombinerade bio- och solvaermesystem. Handbok foer systemutformning

    Energy Technology Data Exchange (ETDEWEB)

    Persson, Tomas

    2008-11-15

    The purpose of this report is to compile the knowledge available concerning combined pellets and solar system in order to support companies in their systems design. This publication deals with experience gained in research on solar and pellet heating, and gives proposals to system design, various technical solutions, and how systems should be controlled. When solar and pellets are combined, there are many possibilities to interconnect the systems. There are different traditions in different countries, which makes the system solutions vary from country to country. A general conclusion is that conventional Swedish boilers with built-in hot water heater are not appropriate for conventional solar systems. It gives rise to complex solutions and it is difficult to achieve good stratification in the water tank. In a solar system, it is important that the tank can be discharged in such a way that sharp stratification is obtained. This means that the tank bottom must be chilled to the temperature of incoming cold water and that the middle part must be cooled to the same temperature as the radiator return. If solar panels even in winter can work to preheat the cold water of 10 to 20 C, a much better efficiency is obtained on collectors than if the radiator return must be preheated, which at best is at a temperature level of between 30 and 40 C. To this end, the radiator return is placed well up from the bottom of the tank and the tap water is preheated in a loop that starts in the tank bottom. Another important parameter in the tank design is that heat losses are kept low, it is important that the solar heat can produce the hot water even during overcast periods in summer and to keep energy consumption low. In modern houses where the tank is placed in the living area, it is important to avoid high temperatures in the room where the tank is placed. To obtain a good isolation one must ensure that there is an airtight layer across the isolation that also closes tightly against

  18. Optimum power yield for bio fuel fired combined heat and power plants

    Energy Technology Data Exchange (ETDEWEB)

    Broden, Henrik; Nystroem, Olle; Joensson, Mikael

    2012-05-15

    Plant owners, suppliers, research institutions, industry representatives and (supporting) authorities are continuing to question the viability of what can be expected by increasing the steam data and the efficiency of cogeneration plants. In recent years, the overall conditions for investment in CHP have changed. Today, there is access to new materials that allow for more advanced steam data while maintaining availability. Although the financial environment with rising prices of electricity, heating and fuel along with the introduction of energy certificates and the interest in broadening the base of fuel has changed the situation. At the same time as the increased interest in renewable energy production creates competition among energy enterprises to find suppliers, increased prices for materials and labor costs have also resulted in increased investment and maintenance costs. Research on advanced steam data for biomass-fired power cogeneration plants has mainly emphasized on technical aspects of material selection and corrosion mechanisms based on performance at 100 % load looking at single years. Reporting has rarely been dealing with the overall economic perspective based on profitability of the CHP installations throughout their entire depreciation period. In the present report studies have been performed on how the choice of steam data affects the performance and economy in biomass-fired cogeneration plants with boilers of drum type and capacities at 30, 80 and 160 MWth with varied steam data and different feed water system configurations. Profitability is assessed on the basis of internal rate of return (IRR) throughout the amortization period of the plants. In addition, sensitivity analyses based on the most essential parameters have been carried out. The target group for the project is plant owners, contractors, research institutions, industry representatives, (supporting) authorities and others who are faced with concerns regarding the viability of what

  19. Simulation and optimization study on a solar space heating system combined with a low temperature ASHP for single family rural residential houses in Beijing

    DEFF Research Database (Denmark)

    Deng, Jie; Tian, Zhiyong; Fan, Jianhua

    2016-01-01

    A pilot project of the solar water heating system combined with a low temperature air source heat pump (ASHP) unit was established in 2014 in a detached residential house in the rural region of Beijing, in order to investigate the system application prospect for single family houses via system op...... the integrated solar space heating for reducing carbon emission, it is suggested that the Beijing municipal government should offer some financial subsidy to compensate the equivalent solar heat price per kWh....... pilot household on the current electricity price level of 0.5 RMB/kWh, comparing with the reference condition of the fully ASHP space heating. It is further found that the equivalent solar heat price per kWh is too high under the current solar market cost price and collector technology. To put forward...

  20. Corrosion investigations at Masnedoe combined heat and power plant. Part VI

    Energy Technology Data Exchange (ETDEWEB)

    Montgomery, M. [Danmarks Tekniske Univ., Dept. for Manufacturing Engineering, Kgs Lyngby (Denmark); Karlsson, A. [ENERGI E2, Power Company, Copenhagen (Denmark); Hede Larsen, O. [Elsam - Fynsvaerket, Fredericia (Denmark)

    2001-02-01

    In Denmark, straw and other types of biomass are used for generating energy in power plats. Straw is considered a carbon dioxide neutral fuel and is therefore environmentally acceptable. Masnedoe CHP Plant is a straw-fired power plant on Sjaelland, Denmark. Corrosion tests were undertaken at Masnedoe CHP Plant by building a test superheater loop and subject it to higher steam temperatures than those of the actual plant. In addition a test section welded into superheater was investigated. The conclusions from the project are as follows: 1. The corrosion rates of the steels investigated are very close to one another and differences are small. 2. For the lower steam of 450 deg. C, a parabolic kinetic of oxide growth is not seen but more a paralinear corrosion rate for TP347H and a linear corrosion rate for the 12% Cr steel. 3. At temperatures above approx. 520 deg. C metal temperature for the austenitic steels, grain boundary attack is seen as a precursor for corrosion within the metal grains. For HCM12, attack of individual metal grains is also seen. The corrosion attack leads to depletion of chromium and manganese from the surface of the alloy. It is at these temperatures general corrosion changes to grain boundary corrosion attack. 4. Over one of the test superheater loops, varying corrosion rates could be measured that could not be explained by the change in steam temperature. This was related to the flue gas direction giving a higher surface metal temperature, however, there may be other factors giving localised high heat flux and therefore a higher metal temperature. The corrosion rate was lower this year (1999-2000) than the previous year and this is attributed to the lower flue gas temperatures or other factors such as a change in fuel or combustion characteristics. It must be noted that where the flue gas temperature is assumed to be highest similar corrosion rates are observed for both 1998-1999 and 1999-2000. There is much evidence to indicate that after

  1. Water vapour and heat combine to elicit biting and biting persistence in tsetse.

    Science.gov (United States)

    Chappuis, Charles J F; Béguin, Steve; Vlimant, Michèle; Guerin, Patrick M

    2013-08-19

    Tsetse flies are obligatory blood feeders, accessing capillaries by piercing the skin of their hosts with the haustellum to suck blood. However, this behaviour presents a considerable risk as landing flies are exposed to predators as well as the host's own defense reactions such as tail flicking. Achieving a successful blood meal within the shortest time span is therefore at a premium in tsetse, so feeding until replete normally lasts less than a minute. Biting in blood sucking insects is a multi-sensory response involving a range of physical and chemical stimuli. Here we investigated the role of heat and humidity emitted from host skin on the biting responses of Glossina pallidipes, which to our knowledge has not been fully studied in tsetse before. The onset and duration of the biting response of G. pallidipes was recorded by filming movements of its haustellum in response to rapid increases in temperature and/or relative humidity (RH) following exposure of the fly to two airflows. The electrophysiological responses of hygroreceptor cells in wall-pore sensilla on the palps of G. pallidipes to drops in RH were recorded using tungsten electrodes and the ultra-structure of these sensory cells was studied by scanning and transmission electron microscopy. Both latency and proportion of tsetse biting are closely correlated to RH when accompanied by an increase of 13.1°C above ambient temperature but not for an increase of just 0.2°C. Biting persistence, as measured by the number of bites and the time spent biting, also increases with increasing RH accompanied by a 13.1°C increase in air temperature. Neurones in wall-pore sensilla on the palps respond to shifts in RH. Our results show that temperature acts synergistically with humidity to increase the rapidity and frequency of the biting response in tsetse above the levels induced by increasing temperature or humidity separately. Palp sensilla housing hygroreceptor cells, described here for the first time in tsetse

  2. The influence of operating temperature on the efficiency of a combined heat and power fuel cell plant

    Science.gov (United States)

    Au, S. F.; McPhail, S. J.; Woudstra, N.; Hemmes, K.

    It is generally accepted that the ideal operating temperature of a molten carbonate fuel cell (MCFC) is 650 °C. Nevertheless, when waste heat utilization in the form of an expander and steam production cycle is introduced in the system, another temperature level might prove more productive. This article is a first attempt to the optimization of MCFC operating temperatures of a MCFC system by presenting a case study in which the efficiency of a combined heat and power (CHP) plant is analyzed. The fuel cell plant under investigation is designed around a 250 kW-class MCFC fuelled by natural gas, which is externally reformed by a heat exchange reformer (HER). The operating temperature of the MCFC is varied over a temperature range between 600 and 700 °C while keeping the rest of the system the same as far as possible. Changes in energetic efficiency are given and the causes of these changes are further analyzed. Furthermore, the exergetic efficiencies of the system and the distribution of exergy losses in the system are given. Flowsheet calculations show that there is little dependency on the temperature in the first order. Both the net electrical performance and the overall exergetic performance show a maximum at approximately 675 °C, with an electrical efficiency of 51.9% (LHV), and an exergy efficiency of 58.7%. The overall thermal efficiency of this CHP plant increases from 87.1% at 600 °C to 88.9% at 700 °C. Overall, the change in performance is small in this typical range of MCFC operating temperature.

  3. Analysis and Assessments of Combined Cooling, Heating and Power Systems in Various Operation Modes for a Building in China, Dalian

    Directory of Open Access Journals (Sweden)

    Huanan Li

    2013-05-01

    Full Text Available Combined Cooling, Heating and Power (CCHP systems have been widely used in different kinds of buildings to make better use of fuels because of their high overall efficiency. This paper presents a mathematical analysis of a CCHP system in comparison to a Heating, Ventilation and Air Conditioning (HVAC system. The operation strategies following electric load (FEL, thermal load (FTL and a hybrid electric-thermal load (FHL are proposed and investigated in this study. Criteria, namely primary energy saving (PES, exergy efficiency (ηexergy, and CO2 emission reduction (CER are defined to evaluate the performances of CCHP systems for a hypothetical building located in Dalian (China. The results indicate that: (1 a new mathematical foundation is established to find whether the recovered thermal energy and the amount of electricity generated by the power generation unit (PGU are enough to provide the energy required; (2 the CCHP system does not always perform better than a HVAC system from an instantaneous perspective, especially in FTL mode; (3 the CCHP system in FEL operation mode can be seen as a suitable energy system in Dalian from the annual performance perspective. Furthermore, a sensitivity analysis is presented in order to show how the performances vary due to the changes of various technical variables.

  4. Optimal Operation of Combined Heat and Power System Based on Forecasted Energy Prices in Real-Time Markets

    Directory of Open Access Journals (Sweden)

    Chenghong Gu

    2015-12-01

    Full Text Available This paper develops a discrete operation optimization model for combined heat and powers (CHPs in deregulated energy markets to maximize owners’ profits, where energy price forecasting is included. First, a single input and multi-output (SIMO model for typical CHPs is established, considering the varying ratio between heat and electricity outputs at different loading levels. Then, the energy prices are forecasted with a gray forecasting model and revised in real-time based on the actual prices by using the least squares method. At last, a discrete optimization model and corresponding dynamic programming algorithm are developed to design the optimal operation strategies for CHPs in real-time. Based on the forecasted prices, the potential operating strategy which may produce the maximum profits is pre-developed. Dynamic modification is then conducted to adjust the pre-developed operating strategy after the actual prices are known. The proposed method is implemented on a 1 MW CHP on a typical day. Results show the optimized profits comply well with those derived from real-time prices after considering dynamic modification process.

  5. [Clinical Observation of Heat-sensitive Moxibustion Combined with Kegel Exercise Therapy for Female Stress Urinary Incontinence].

    Science.gov (United States)

    Hu, Dan; Deng, Peng; Jiao, Lin; Xiong, Jun; Xie, Ding-Yi; Chen, Ri-Xin

    2017-08-25

    To compare the clinical effects of heat-sensitive moxibustion combined with kegel exercise therapy and simple kegel exercise therapy on female stress urinary incontinence. Forty-five female patients with stress urinary incontinence were randomly divided into a treatment group ( n =23) and a control group ( n =22). Kegel exercise therapy was applied in the two groups. Heat-sensitive moxibustion was used at Zhongji (CV 3), Qihai (CV 6), Ciliao (BL 32) and Shen-shu (BL 23) in the treatment group, once a day for the first 10 times, and once every other day until 5 sessions were given, 10 times as one session. 1-hour pad test, International Incontinence Advisory Board questionnaire (ICIQ-SF) and the number of urine leakage were observed before and after treatment. And the clinical effect was evaluated. The curative rate of 43.48%(10/23) and the total effective rate of 95.65%(22/23) in the treatment group were respectively better than those of 18.18% (4/22) and 63.64%(14/22) in the control group (both P kegel exercise therapy achieves better effect than simple kegel exercise therapy on female stress urinary incontinence.

  6. Energy Management of Combined Cooling, Heating and Power Micro Energy Grid Based on Leader-Follower Game Theory

    Directory of Open Access Journals (Sweden)

    Kaijun Lin

    2018-03-01

    Full Text Available In this paper, we consider a general model and solution algorithm for the energy management of combined cooling, heating, and power micro energy grid (MEG under the game theory framework. An innovative dynamic leader-follower game strategy is proposed in this paper to balance the interactions between MEG and user. We show that such game between MEG and user has a unique Nash equilibrium (NE, and in order to quantify the user’s expenditure and dissatisfaction, we model them and adopt the fuzzy bi-objective algorithm. For more details in the proposed game model, the MEG leads the game by deciding energy sales prices and optimizing the power, cooling and heating outputs according to the user’s load plan to maximize its own profit. With the prices being released by MEG, user’s adjustment of energy consumption follows and is again fed to MEG. In practice, we initialize simulations with daily loads of a typical community. As the numerical results demonstrate, MEG is proficient in consumption capacity of renewable energy and energy optimization. It also shows that the user achieves his economic optimum with experience of energy usage taken into account.

  7. [Effect of heat-reinforcing needling combined with rehabilitation training on the motor function of ischemic stroke patients].

    Science.gov (United States)

    Zhang, Ning-xia; Liu, Gui-zhen; Huang, Tai-quan; Li, Wei-jiang; Luo, Jia-qi; Liu, Wei-wei; Huang, Yong; Wang, Ai-min

    2009-12-01

    To observe the therapeutic effect of heat-reinforcing needling combined with modem rehabilitation training on the motor function of ischemic stroke patients. Fifty case of ischemic stroke patients were randomly divided into rehabilitation (Rehab, n=40) and acupuncture (Acup) + Rehab (n=40) groups. Heat-reinforcing needling was applied to Jianyu (LI 15), Quchi (LI 11), Hegu (LI 14), Zusanli (ST 36), Yanglingquan (GB 34), Yinlingquan (SP 9) and Sanyinjiao (SP 6), once daily for 3 weeks. Rehabilitation training including healthy limb and joint movement was conducted, once daily for 3 weeks. The patient's neurological impairment degree and the motor function (Fugl-Meyer index) were evaluated before and after the treatment. After the treatment, of the each 40 cases in Rehab and Acup + Rehab groups, 10 (25.0%) and 17 (42.5%) experienced marked improvement in their symptoms, 17 (42.5%) and 18 (45.0%) had improvement, 13 (32.5%) and 5 (12.5%) failed, with the effective rates being 67.5% and 87.5% respectively. The therapeutic effect of Acup + Rehab group was markedly superior to that of Rehab group (P0.05). After the treatment, the scores of neurological impairment degree of two groups both decreased significantly (PRehab group was significantly lower than that of Rehab group (PRehab group were obviously higher than those of Rehab group (Pstroke patients.

  8. Electricity and combined heat and power from municipal solid waste; theoretically optimal investment decision time and emissions trading implications.

    Science.gov (United States)

    Tolis, Athanasios; Rentizelas, Athanasios; Aravossis, Konstantin; Tatsiopoulos, Ilias

    2010-11-01

    Waste management has become a great social concern for modern societies. Landfill emissions have been identified among the major contributors of global warming and climate changes with significant impact in national economies. The energy industry constitutes an additional greenhouse gas emitter, while at the same time it is characterized by significant costs and uncertain fuel prices. The above implications have triggered different policies and measures worldwide to address the management of municipal solid wastes on the one hand and the impacts from energy production on the other. Emerging methods of energy recovery from waste may address both concerns simultaneously. In this work a comparative study of co-generation investments based on municipal solid waste is presented, focusing on the evolution of their economical performance over time. A real-options algorithm has been adopted investigating different options of energy recovery from waste: incineration, gasification and landfill biogas exploitation. The financial contributors are identified and the impact of greenhouse gas trading is analysed in terms of financial yields, considering landfilling as the baseline scenario. The results indicate an advantage of combined heat and power over solely electricity production. Gasification, has failed in some European installations. Incineration on the other hand, proves to be more attractive than the competing alternatives, mainly due to its higher power production efficiency, lower investment costs and lower emission rates. Although these characteristics may not drastically change over time, either immediate or irreversible investment decisions might be reconsidered under the current selling prices of heat, power and CO(2) allowances.

  9. Analysis of combined conduction and radiation heat transfer in presence of participating medium by the development of hybrid method

    International Nuclear Information System (INIS)

    Mahapatra, S.K.; Dandapat, B.K.; Sarkar, A.

    2006-01-01

    The current study addresses the mathematical modeling aspects of coupled conductive and radiative heat transfer in the presence of absorbing, emitting and isotropic scattering gray medium within two-dimensional square enclosure. A blended method where the concepts of modified differential approximation employed by combining discrete ordinate method and spherical harmonics method, has been developed for modeling the radiative transport equation. The gray participating medium is bounded by isothermal walls of two-dimensional enclosure which are considered to be opaque, diffuse and gray. The effect of various influencing parameters i.e., radiation-conduction parameter, surface emissivity, single scattering albedo and optical thickness has been illustrated. The adaptability of the present method has also been addressed

  10. A two-stage optimal planning and design method for combined cooling, heat and power microgrid system

    International Nuclear Information System (INIS)

    Guo, Li; Liu, Wenjian; Cai, Jiejin; Hong, Bowen; Wang, Chengshan

    2013-01-01

    Highlights: • A two-stage optimal method is presented for CCHP microgrid system. • Economic and environmental performance are considered as assessment indicators. • Application case demonstrates its good economic and environmental performance. - Abstract: In this paper, a two-stage optimal planning and design method for combined cooling, heat and power (CCHP) microgrid system was presented. The optimal objective was to simultaneously minimize the total net present cost and carbon dioxide emission in life circle. On the first stage, multi-objective genetic algorithm based on non-dominated sorting genetic algorithm-II (NSGA-II) was applied to solve the optimal design problem including the optimization of equipment type and capacity. On the second stage, mixed-integer linear programming (MILP) algorithm was used to solve the optimal dispatch problem. The approach was applied to a typical CCHP microgrid system in a hospital as a case study, and the effectiveness of the proposed method was verified

  11. A demonstration of the improved efficiency of the canonical coordinates method using nonlinear combined heat and power economic dispatch problems

    Science.gov (United States)

    Chang, Hung-Chieh; Lin, Pei-Chun

    2014-02-01

    Economic dispatch is the short-term determination of the optimal output from a number of electricity generation facilities to meet the system load while providing power. As such, it represents one of the main optimization problems in the operation of electrical power systems. This article presents techniques to substantially improve the efficiency of the canonical coordinates method (CCM) algorithm when applied to nonlinear combined heat and power economic dispatch (CHPED) problems. The improvement is to eliminate the need to solve a system of nonlinear differential equations, which appears in the line search process in the CCM algorithm. The modified algorithm was tested and the analytical solution was verified using nonlinear CHPED optimization problems, thereby demonstrating the effectiveness of the algorithm. The CCM methods proved numerically stable and, in the case of nonlinear programs, produced solutions with unprecedented accuracy within a reasonable time.

  12. HEAT PUMP STATION WITH CARBON DIOXIDE AS A WORKING FLUID ENERGY EFFICIENCY GROWTH IN COMBINED DISTRICT HEATING SYSTEM DUE TO ITS CONTROL SYSTEM OPTIMIZATION

    Directory of Open Access Journals (Sweden)

    Sit B.M.

    2008-04-01

    Full Text Available A diagram of the heat pump station (HPS for the central heat supply station of the district heating system, which gets the power from the CHP plant is examined. A block diagram of the control of the system and compressor pressure control system are examined. The description of the control laws of evaporator at the variable heat load of the HPS and control laws of the gas cooler taking into account the goal of achieving the maximum of COP of HPS is shown as well.

  13. Combined resistive and laser heating technique for in situ radial X-ray diffraction in the diamond anvil cell at high pressure and temperature

    Energy Technology Data Exchange (ETDEWEB)

    Miyagi, Lowell [Department of Geology and Geophysics, University of Utah, Salt Lake City, Utah 84112 (United States); Department of Earth Sciences, Montana State University, Bozeman, Montana 59717 (United States); Kanitpanyacharoen, Waruntorn; Kaercher, Pamela; Wenk, Hans-Rudolf; Alarcon, Eloisa Zepeda [Department of Earth and Planetary Science, University of California, Berkeley, California 94720 (United States); Raju, Selva Vennila [Advanced Light Source, Lawrence Berkeley Laboratory, Berkeley, California 94720 (United States); HiPSEC, Department of Physics, University of Nevada, Las Vegas, Nevada 89154 (United States); Knight, Jason; MacDowell, Alastair [Advanced Light Source, Lawrence Berkeley Laboratory, Berkeley, California 94720 (United States); Williams, Quentin [Department of Earth and Planetary Science, University of California, Santa Cruz, California 95064 (United States)

    2013-02-15

    To extend the range of high-temperature, high-pressure studies within the diamond anvil cell, a Liermann-type diamond anvil cell with radial diffraction geometry (rDAC) was redesigned and developed for synchrotron X-ray diffraction experiments at beamline 12.2.2 of the Advanced Light Source. The rDAC, equipped with graphite heating arrays, allows simultaneous resistive and laser heating while the material is subjected to high pressure. The goals are both to extend the temperature range of external (resistive) heating and to produce environments with lower temperature gradients in a simultaneously resistive- and laser-heated rDAC. Three different geomaterials were used as pilot samples to calibrate and optimize conditions for combined resistive and laser heating. For example, in Run1, FeO was loaded in a boron-mica gasket and compressed to 11 GPa then gradually resistively heated to 1007 K (1073 K at the diamond side). The laser heating was further applied to FeO to raise temperature to 2273 K. In Run2, Fe-Ni alloy was compressed to 18 GPa and resistively heated to 1785 K (1973 K at the diamond side). The combined resistive and laser heating was successfully performed again on (Mg{sub 0.9}Fe{sub 0.1})O in Run3. In this instance, the sample was loaded in a boron-kapton gasket, compressed to 29 GPa, resistive-heated up to 1007 K (1073 K at the diamond side), and further simultaneously laser-heated to achieve a temperature in excess of 2273 K at the sample position. Diffraction patterns obtained from the experiments were deconvoluted using the Rietveld method and quantified for lattice preferred orientation of each material under extreme conditions and during phase transformation.

  14. Combined resistive and laser heating technique for in situ radial X-ray diffraction in the diamond anvil cell at high pressure and temperature.

    Science.gov (United States)

    Miyagi, Lowell; Kanitpanyacharoen, Waruntorn; Raju, Selva Vennila; Kaercher, Pamela; Knight, Jason; MacDowell, Alastair; Wenk, Hans-Rudolf; Williams, Quentin; Alarcon, Eloisa Zepeda

    2013-02-01

    To extend the range of high-temperature, high-pressure studies within the diamond anvil cell, a Liermann-type diamond anvil cell with radial diffraction geometry (rDAC) was redesigned and developed for synchrotron X-ray diffraction experiments at beamline 12.2.2 of the Advanced Light Source. The rDAC, equipped with graphite heating arrays, allows simultaneous resistive and laser heating while the material is subjected to high pressure. The goals are both to extend the temperature range of external (resistive) heating and to produce environments with lower temperature gradients in a simultaneously resistive- and laser-heated rDAC. Three different geomaterials were used as pilot samples to calibrate and optimize conditions for combined resistive and laser heating. For example, in Run#1, FeO was loaded in a boron-mica gasket and compressed to 11 GPa then gradually resistively heated to 1007 K (1073 K at the diamond side). The laser heating was further applied to FeO to raise temperature to 2273 K. In Run#2, Fe-Ni alloy was compressed to 18 GPa and resistively heated to 1785 K (1973 K at the diamond side). The combined resistive and laser heating was successfully performed again on (Mg0.9Fe0.1)O in Run#3. In this instance, the sample was loaded in a boron-kapton gasket, compressed to 29 GPa, resistive-heated up to 1007 K (1073 K at the diamond side), and further simultaneously laser-heated to achieve a temperature in excess of 2273 K at the sample position. Diffraction patterns obtained from the experiments were deconvoluted using the Rietveld method and quantified for lattice preferred orientation of each material under extreme conditions and during phase transformation.

  15. West Chester Work Center: solar space heating demonstration project

    Energy Technology Data Exchange (ETDEWEB)

    1979-05-01

    This document reports on the construction stage of a solar space heating demonstration project. It describes an integrated system providing solar energy space heating for a 9982 sq. ft., newly built, one-story building. The building is located at 966 Matlack Street, West Goshen Township, Chester County, Pennsylvania. Functionally, the building consists of two sections: An Office and a Storeroom. The Office section is heated by solar-assisted water-to-air heat pump units. The Storeroom section is heated by an air-handling unit, containing a water-to-air coil. Solar energy is expected to provide 62% of the heating load, with the balance provided by a back-up electric boiler. The system includes 1900 active (2112 gross) square feet of flat-plate solar collectors, and a 6000 gallon above-ground indoor storage tank. Freeze protection is provided by a gravity drain-down scheme combined with nitrogen pressurization in a closed circuit.

  16. Analysis of an effective solution to excessive heat supply in a city primary heating network using gas-fired boilers for peak-load compensation

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Hai-Chao; Jiao, Wen-Ling; Zou, Ping-Hua; Liu, Jing-Cheng [School of Municipal and Environmental Engineering, Harbin Institute of Technology, mail box 2645, 202 Haihe Road, Nangang District, Harbin 150090 (China)

    2010-11-15

    Through investigation of the Dengfeng heating network in the city of Daqing, China, for the 2007-2008 heating season, we found serious problems of excessive heat supply in the primary heating network. Therefore, we propose the application of gas-fired boilers in underperforming heating substations as peak-load heat sources to effectively adapt to the regulation demands of seasonal heat-load fluctuations and reduce the excessive heat supply. First, we calculated the excessive heat supply rates (EHSRs) of five substations using detailed investigative data. We then discussed the feasibility of the proposed scheme providing energy savings from both energetic and exergetic points of view. The results showed that the average EHSR of the five substations between January and March was 20.57% of the gross heat production but consequently reduced to 6.24% with the installation of the gas-fired boilers. Therefore, the combined heating scheme with coal as the basic heat-source and gas-fired boilers as peak-load heat sources is energy-efficient to some extent, although requires the use of natural gas. Meanwhile, the exergy decreased by 10.97%, which indicates that the combined heating scheme effectively reduces the primary energy consumption and pollutant emission of the heating systems. (author)

  17. Modelling and multi-scenario analysis for electric heat tracing system combined with low temperature district heating for domestic hot water supply

    DEFF Research Database (Denmark)

    Yang, Xiaochen; Li, Hongwei; Svendsen, Svend

    2016-01-01

    of the electric heating tracing system with LTDH was simulated by taking the user pattern into account. A smart control method based on thermostatic and real-time control was developed, and compared with normal control method. The impact of user pattern was tested by applying standard, stochastic, and real load......Low temperature district heating (LTDH) is a cost-efficient way of supplying space heating and domestic hot water (DHW) for buildings in urban areas. However, there is concern that the potential hygiene problems (Legionella) might occur if LTDH is implemented, especially for large buildings....... In this study, electric heat tracing system was investigated as a solution to this dilemma. A model of electric heat tracing system for multi-storey buildings was built. Various pipe materials and insulation thicknesses as the parameters of the model were compared to make a comprehensive study. The performance...

  18. Drying and heat transfer behavior of banana undergoing combined low-pressure superheated steam and far-infrared radiation drying

    International Nuclear Information System (INIS)

    Nimmol, Chatchai; Devahastin, Sakamon; Swasdisevi, Thanit; Soponronnarit, Somchart

    2007-01-01

    The present study aimed at investigating the use of a drying system combining the concept of already proven low-pressure superheated steam drying and far-infrared radiation (LPSSD-FIR) for banana. The effects of various operating parameters, i.e., drying medium temperature and pressure, on the drying kinetics and heat transfer behavior of banana as well as the energy consumption of the process were investigated and discussed. Comparison was also made with similar sets of data obtained from the system with combined far-infrared radiation and vacuum drying (VACUUM-FIR) and the system using only low-pressure superheated steam drying (LPSSD). The results showed that LPSSD-FIR and VACUUM-FIR took shorter drying time compared to LPSSD at all drying conditions. In terms of the specific energy consumption, it was observed that the specific energy consumption of the vacuum pump was much higher than that of the far-infrared radiator or electric heater. It was also found that the specific energy consumption of LPSSD-FIR and VACUUM-FIR were lower than that of LPSSD at all drying conditions. Based on the drying rates and the specific energy consumption of all tested processes, LPSSD-FIR at 90 deg. C and 7 kPa was suggested

  19. Combination therapy for hepatitis C virus with heat-shock protein 90 inhibitor 17-AAG and proteasome inhibitor MG132.

    Science.gov (United States)

    Ujino, Saneyuki; Yamaguchi, Saori; Shimotohno, Kunitada; Takaku, Hiroshi

    2010-03-09

    Hepatitis C virus (HCV) infection is a major cause of chronic liver disease. Here, we report a new and effective strategy for inhibiting HCV replication using an inhibitor of heat-shock protein 90, 17-AAG (17-allylamino-17demethoxygeldanamycin), and a proteasome inhibitor, MG132. To explore the virological basis of combination therapy, we analysed the effects of 17-AAG and MG132, singly and in combination on HCV replication in an HCV replicon cell system. In HCV replicon cells, HCV RNA replication was suppressed by 17-AAG in a dose-dependent manner. As shown in the present study, the 50% inhibitory concentration values were 0.82 nM for 17-AAG and 0.21 nM for MG132. Low concentrations of MG132 had strong synergistic inhibitory effects with low toxicity on HCV replicon cells. The results of this study suggest that the different effects and synergistic actions of 17-AAG and MG132 could provide a new therapeutic approach to HCV infection.

  20. Effect of drought and combined drought and heat stress on polyamine metabolism in proline-over-producing tobacco plants.

    Science.gov (United States)

    Cvikrová, Milena; Gemperlová, Lenka; Martincová, Olga; Vanková, Radomira

    2013-12-01

    The roles of proline and polyamines (PAs) in the drought stress responses of tobacco plants were investigated by comparing the responses to drought alone and drought in combination with heat in the upper and lower leaves and roots of wild-type tobacco plants and transformants that constitutively over-express a modified gene for the proline biosynthetic enzyme Δ1-pyrroline-5-carboxylate synthetase (P5CSF129A; EC 2.7.2.11/1.2.1.41). In both genotypes, drought stress coincided with a decrease in relative water content (RWC) that was much less severe in the upper leaves than elsewhere in the plant. The drought also increased proline levels in both genotypes. A brief period of heat stress (2 h at 40 °C) at the end of the drought period did not significantly influence the proline levels in the upper leaves and roots but caused a further increase in the lower leaves of both genotypes. The rate at which these elevated proline levels returned to normal during the post-stress recovery period was slower in the transformants and plants that had been subjected to the combined stress. In both genotypes, drought stress significantly reduced the levels of spermidine (Spd) and putrescine (Put) in the leaves and roots relative to those for controls, and increased the levels of spermine (Spm) and diaminopropane (Dap, formed by the oxidative deamination of Spd and Spm). Spd levels may have declined due to its consumption in Spm biosynthesis and/or oxidation by polyamine oxidase (PAO; EC 1.5.3.11) to form Dap, which became more abundant during drought stress. During the rewatering period, the plants' Put and Spd levels recovered quickly and the activity of the PA biosynthesis enzymes in their leaves and roots increased substantially; this increase was more pronounced in transformants than WT plants. The high levels of Spm observed in drought stressed plants persisted even after the 24 h recovery and rewatering phase. The malondialdehyde (MDA) contents of the lower leaves of WTs

  1. Validating the Rett Syndrome Gross Motor Scale.

    Science.gov (United States)

    Downs, Jenny; Stahlhut, Michelle; Wong, Kingsley; Syhler, Birgit; Bisgaard, Anne-Marie; Jacoby, Peter; Leonard, Helen

    2016-01-01

    Rett syndrome is a pervasive neurodevelopmental disorder associated with a pathogenic mutation on the MECP2 gene. Impaired movement is a fundamental component and the Rett Syndrome Gross Motor Scale was developed to measure gross motor abilities in this population. The current study investigated the validity and reliability of the Rett Syndrome Gross Motor Scale. Video data showing gross motor abilities supplemented with parent report data was collected for 255 girls and women registered with the Australian Rett Syndrome Database, and the factor structure and relationships between motor scores, age and genotype were investigated. Clinical assessment scores for 38 girls and women with Rett syndrome who attended the Danish Center for Rett Syndrome were used to assess consistency of measurement. Principal components analysis enabled the calculation of three factor scores: Sitting, Standing and Walking, and Challenge. Motor scores were poorer with increasing age and those with the p.Arg133Cys, p.Arg294* or p.Arg306Cys mutation achieved higher scores than those with a large deletion. The repeatability of clinical assessment was excellent (intraclass correlation coefficient for total score 0.99, 95% CI 0.93-0.98). The standard error of measurement for the total score was 2 points and we would be 95% confident that a change 4 points in the 45-point scale would be greater than within-subject measurement error. The Rett Syndrome Gross Motor Scale could be an appropriate measure of gross motor skills in clinical practice and clinical trials.

  2. Thermo economic comparison of conventional micro combined heat and power systems with solid oxide fuel cell systems for small scale applications

    DEFF Research Database (Denmark)

    Batens, Ellen; Cuellar, Rafael; Marissal, Matthieu

    2013-01-01

    out a thermo economic comparison of a conventional micro combined heat and power systems with solid oxide fuel cell systems. A model to estimate the savings and cost targets for solid oxide fuel cell systems is presented. A comparison between fuel cell technologies in the danish market with “state...... of the art” traditional heat and power generation technologies currently used in Denmark is considered. The conventional method of covering electrical, heating (e.g. hot water) and cooling (e.g. space cooling) load demands is by purchasing electricity from the electricity network grid and with a fossil fuel...

  3. Integration of bio-fired gas turbines in combined heat and power generation; Integrering av biogaseldad gasturbin i kraftvaermeanlaeggning

    Energy Technology Data Exchange (ETDEWEB)

    Genrup, Magnus; Jonshagen, Klas

    2011-01-15

    The aim of the project was to perform a pre-study of the potential to introduce a biofired gas turbine into the pre-heater train of a district heating plant. The incentive for the work is the desire (and political drivers) to increase bio-fuel usage in heat and power production. Sweden has also ratified the EU treaty of having 20 percent renewable in the system before 2020. There are several options at the hand but locally produced biofuels from either gasification or biological processes can be fired in a gas turbine. The size of the gas turbine is limited by shear size of the fuel plant and raw-material transport issues. Today, the maximum electrical efficiency for large-scale advanced plants is on the order of 60 percent. This level is, however, not feasible for smaller size units and one can expect much lower levels. Another possibility is to re-power an existing plant and use the exhaust heat from the gas turbine. Either to produce steam in a heat recovery steam generator, heat boiler combustion air (and variants) or to reduce pre-heater extraction through by-passing the pre-heaters. Previous studies have shown that one could expect very high efficiency levels if the heat could be utilized in the feed water to the boiler. This is typically coupled to the admission pressure level and super-critical plant may have feed water temperature exceeding 300 deg C. The aim of this project was to investigate the potential from introducing this technology into a certain typical Swedish/Nordic turbine based district heating plant. A typical plant has modest admission data (compared to an ultra super-critical plant), hence lower final feed water temperature. A lower final temperature makes it more troublesome to effectively use the exhaust heat from the gas turbine. A further improvement is possible by introducing reheat. There are several practical limitations, where the most severe is the need to extract the full turbine flow and induce it after the reheater. The only

  4. Requirement of radiochemical recovery determination for gross alpha and gross beta estimation in drinking water

    International Nuclear Information System (INIS)

    Raveendran, Nanda; Rao, D.D.; Hegde, A.G.

    2010-01-01

    Presence of radionuclides in drinking water which emits Alpha and Beta particles are the potential sources of internal exposure in drinking water. Gross alpha and gross beta determination in drinking water and packaged drinking water (PDW) as per BIS (Bureau of Indian standards) standards is discussed here. The methods have been tested to account for losses in the radiochemical procedures using radionuclides such as 137 Cs, 90 Sr, 226 Ra, 239 Pu, 243 Am, 232 U. The methods have also been validated in an IAEA proficiency test conducted during 2009. Monitoring of gross alpha and gross beta activity observed in drinking water/packaged drinking water from various states of India were within the limits set by BIS. Average radiochemical recoveries of 84% and 63% were obtained for gross α and gross β respectively. (author)

  5. Regulation and energy conservation. The case of combined heat and power in the European Union. Situation and prospects

    International Nuclear Information System (INIS)

    Hendriks, C.; Worrell, E.; Blok, K.; Velthuijsen, J.W.

    1995-02-01

    Policy measures to stimulate the proliferation of combined heat and power generation (CHP) have been motivated because of the energy efficiency potential. In this paper we investigate to what extent the penetration of CHP has taken place in the 12 member states of the European Union (EU-12). Also analyzed is the potential heat demand which can be covered by CHP, and the corresponding amount of capacity for each country. A short overview is given of the goals for CHP capacity for some of the EU-12 member states. We distinguish two different kinds of policy instruments: standard settings and economic instruments. Four different types of standard settings are given. We evaluate a specific standard setting which is applied in the Netherlands in the 1970's and early 1980's. The economic instruments are evaluated in terms of payback time. This payback period can be influenced by for instance an investment grant, tax on the emission of carbon dioxide, a raise of selling electricity to the public grid and lower the price for natural gas for CHP applications. Finally, we give some recommendations how EU policy may stimulate the application of CHP. In section 2 we describe the development of CHP from 1974 to 1990 in the EU-12 member states. and the intentions stated by the national governments. In section 3 we give an overview of the potential capacity of CHP. In section 4 we discuss the regulation instruments: standard settings and economical instruments. In section 5 we give some conclusions especially with regard to EU policy options. 23 refs

  6. The solution of the two-dimensional inverse heat transfer problem with the use of the FEM in combination with Trefftz functions

    Directory of Open Access Journals (Sweden)

    Maciejewska Beata

    2012-04-01

    Full Text Available The aim of this paper is to determine the boiling heat transfer coefficient for the cooling liquid flow in a rectangular minichannel with asymmetric heating. The main part of the test section is made up of a vertical minichannel of 1.0 mm depth. The heating foil on the side of the fluid flowing in the minichannel is singlesided enhanced on the selected area. The experiment is carried out with FC-72. The investigations focus on the transition from single-phase forced convection to nucleate boiling, that is, from the zone of boiling incipience further to developed boiling. Owing to the liquid crystal layer located on the heating surface contacting the glass, it is possible to measure the heating wall temperature distribution while increasing the heat flux transferred to the liquid flowing in the minichannel. The objective of the calculations is to evaluate a heat transfer model and numerical approach to solving the inverse boundary problem, and to calculate the heat transfer coefficient. This problem has been solved by means the finite element method in combination with Trefftz functions (FEMT. Trefftz functions are used to construct base functions in Hermite space of the finite element.

  7. The effects of frost thickness on the heat transfer of finned tube heat exchanger subject to the combined influence of fan types

    Energy Technology Data Exchange (ETDEWEB)

    Huang, Jeng-Min; Hsieh, Wen-Chien; Ke, Xin-Ji [Department of Refrigeration, Air Conditioning National Chin-Yi University of Technology, Taichung County, Taiping City 411 (China); Wang, Chi-Chuan [Energy and Environment Research Laboratories, Industrial Technology Research Institute, Hsinchu 310 (China)

    2008-05-15

    This study conducts a numerical study concerning the effect of frost thickness on the heat transfer performance of a four rows plate finned tube heat exchanger. Calculations are made under constant air volume and variable air volume conditions. It is found that the initial surge of heat transfer rate in the frosted finned tube heat exchanger is mainly associated with the critical radius effect rather than the surface roughness. The frost thermal conductivity plays an important role in the surge phenomenon. There is hardly any initial surge when frost thermal conductivity is below 0.1 W m{sup -1} K{sup -1}. It is also recommended that a refrigerator should defrost when half of a single flow channel area is blocked by frost. The calculations also reveal that a centrifugal fan is recommended with a small fin-pitch heat exchanger. However, if a long term operation at a thick frost situation is unavoidable, an axial fan should be selected. There is no great difference between selection of an axial fan or centrifugal fan for a larger fin pitch heat exchanger. (author)

  8. Maximisation of Combined Cycle Power Plant Efficiency

    Directory of Open Access Journals (Sweden)

    Janusz Kotowicz

    2015-12-01

    Full Text Available The paper presents concepts for increasing the efficiency of a modern combined cycle power plant. Improvement of gas turbine performance indicators as well as recovering heat from the air cooling the gas turbine’s flow system enable reaching gross electrical efficiencies of around 65%. Analyses for a wide range of compressor pressure ratios were performed. Operating characteristics were developed for the analysed combined cycle plant, for different types of open air cooling arrangements of the gas turbine’s expander: convective, transpiration and film.

  9. Does transcutaneous electrical nerve stimulation (TENS) simultaneously combined with local heat and cold applications enhance pain relief compared with TENS alone in patients with knee osteoarthritis?

    Science.gov (United States)

    Maeda, Takaya; Yoshida, Hideki; Sasaki, Tomoyuki; Oda, Atsushi

    2017-10-01

    [Purpose] The purpose of this study was to investigate whether transcutaneous electrical nerve stimulation simultaneously combined with local heat and cold applications enhances pain relief compared with transcutaneous electrical nerve stimulation alone in patients with knee osteoarthritis. [Subjects and Methods] Fourty-five patients with knee osteoarthritis participated in this study. They were randomly assigned to the following three interventions: transcutaneous electrical nerve stimulation simultaneously combined with local heat using a hot pack; combined with local cold using a cold pack; and transcutaneous electrical nerve stimulation alone. In each intervention, the knee pain level during walking and standing up from a chair, as well as dynamic balance and gait ability were evaluated immediately before and after a single intervention using the visual analogue scale and the timed up & go test, respectively. [Results] A significant improvement in dynamic balance and gait ability was only observed immediately after transcutaneous electrical nerve stimulation simultaneously combined with local heat application, although the degree of pain relief during standing and walking were comparable among the three interventions. [Conclusion] These results suggest that transcutaneous electrical nerve stimulation simultaneously combined with local heat application can immediately improve not only knee pain during standing and walking but also dynamic balance and gait ability in patients with knee osteoarthritis.

  10. Impacts of climate extremes on gross primary production under global warming

    International Nuclear Information System (INIS)

    Williams, I N; Torn, M S; Riley, W J; Wehner, M F

    2014-01-01

    The impacts of historical droughts and heat-waves on ecosystems are often considered indicative of future global warming impacts, under the assumption that water stress sets in above a fixed high temperature threshold. Historical and future (RCP8.5) Earth system model (ESM) climate projections were analyzed in this study to illustrate changes in the temperatures for onset of water stress under global warming. The ESMs examined here predict sharp declines in gross primary production (GPP) at warm temperature extremes in historical climates, similar to the observed correlations between GPP and temperature during historical heat-waves and droughts. However, soil moisture increases at the warm end of the temperature range, and the temperature at which soil moisture declines with temperature shifts to a higher temperature. The temperature for onset of water stress thus increases under global warming and is associated with a shift in the temperature for maximum GPP to warmer temperatures. Despite the shift in this local temperature optimum, the impacts of warm extremes on GPP are approximately invariant when extremes are defined relative to the optimal temperature within each climate period. The GPP sensitivity to these relative temperature extremes therefore remains similar between future and present climates, suggesting that the heat- and drought-induced GPP reductions seen recently can be expected to be similar in the future, and may be underestimates of future impacts given model projections of increased frequency and persistence of heat-waves and droughts. The local temperature optimum can be understood as the temperature at which the combination of water stress and light limitations is minimized, and this concept gives insights into how GPP responds to climate extremes in both historical and future climate periods. Both cold (temperature and light-limited) and warm (water-limited) relative temperature extremes become more persistent in future climate projections

  11. Optimization of the triple-pressure combined cycle power plant

    OpenAIRE

    Alus Muammer; Petrović Milan V.

    2012-01-01

    The aim of this work was to develop a new system for optimization of parameters for combined cycle power plants (CCGTs) with triple-pressure heat recovery steam generator (HRSG). Thermodynamic and thermoeconomic optimizations were carried out. The objective of the thermodynamic optimization is to enhance the efficiency of the CCGTs and to maximize the power production in the steam cycle (steam turbine gross power). Improvement of the efficiency of the CCGT plants is achieved through opt...

  12. Development of a new distillation unit combined with compressed heat pump (heat integrated distillation column (HIDiC)) (eco-energy city project)

    Energy Technology Data Exchange (ETDEWEB)

    Nakanishi, Toshinari; Aso, Kazumasa [Kimura Chemical Plants Co., Ltd., Amagasaki City, Hyogo (Japan); Takamatsu, Takeichiro [Research Inst. of Industrial Technology, Suita-City, Osaka (Japan); Nakaiwa, Masaru [National Inst. of Materials and Chemical Research, Tsukuba, Ibaraki (Japan); Noda, Hideo; Kuratani, Nobuyuki [Kansai Chemical Engineearing Co., Ltd., Amagasaki-city, Hyogo (Japan); Yoshida, Kazufumi [Maruzen Petrochemical Co., Ltd., 25-10, Tokyo (Japan)

    1999-07-01

    To reduce the irreversible loss the Heat Integrated Distillation Column (HIDiC) is proposed by application of heat-pump technology. (Distillation column, which is an energy consuming separation unit, has been widely used in oil refinery and the other chemical-related plants. The reason why it is a major energy consumer is that a large amount of irreversible loss occurs in heat transfer within the process.) In this paper, current results on the study of HIDiC in both simulations and experiments are shown. HIDiC must be operated at a higher pressure in the rectifying section so as to make its temperature higher than that of the stripping section which stands parallel with the rectifying section. That makes heat transfer from the rectifying section to the stripping section. Because of vaporization in the stripping section and condensation in the rectifying section, the energy for the reboiler can be saved. The degree of energy saving can be expected to be much more than 30%, although the exact value depends on the characteristics of mixture to be separated. (The degree of energy saving is higher than the above, if the exhaust vapor from the HIDiC is used to heat the feed or the other processes.) To save energy by the HIDiC, high separation performances and heat transfer capabilities are required. It has been found out that the HIDiC, whose shape is like vertical shell and tube heat exchanger was enough to be practical use of the HIDiC from the static design principle points of view. (orig.)

  13. 78 FR 26575 - Gross Combination Weight Rating; Definition

    Science.gov (United States)

    2013-05-07

    ... submitted on behalf of an association, business, labor union, etc.). You may review the DOT Privacy Act... prohibited from operating CMVs. This rule would have only a limited effect on the risk of driver coercion by... avoid the fact that any decision inconsistent with the rules represents an act of coercion. This...

  14. A passive decay heat removal strategy of the integrated passive safety system (IPSS) for SBO combined with LOCA

    International Nuclear Information System (INIS)

    Kim, Sang Ho; Chang, Soon Heung; Choi, Yu Jung; Jeong, Yong Hoon

    2015-01-01

    Highlights: • A new PDHR strategy is proposed to cope with SBO-combined accidents. • The concept of integrated passive safety system (IPSS) is used in this strategy. • This strategy performs the functions of passive safety injection and SG gravity injection. • LOCAs in SBO are classified by the pressures in reactor coolant system for passive functions. • The strategy can be integrated with EOP and SAMG as a complementary strategy for ensuring safety. - Abstract: An integrated passive safety system (IPSS), to be achieved by the use of a large water tank placed at high elevation outside the containment, was proposed to achieve various passive functions. These include decay heat removal, safety injection, containment cooling, in-vessel retention through external reactor vessel cooling, and containment filtered venting. The purpose of the passive decay heat removal (PDHR) strategy using the IPSS is to cope with SBO and SBO-combined accidents under the assumption that existing engineered safety features have failed. In this paper, a PDHR strategy was developed based on the design and accident management strategy of Korean representative PWR, the OPR1000. The functions of a steam generator gravity injection and a passive safety injection system in the IPSS with safety depressurization systems were included in the PDHR strategy. Because the inadvertent opening of pressurizer valves and seal water leakage from RCPs could cause a loss of coolant in an SBO, LOCAs during a SBO were simulated to verify the performance of the strategy. The failure of active safety injection in LOCAs could also be covered by this strategy. Although LOCAs have generally been categorized according to their equivalent break diameters, the RCS pressure is used to classify the LOCAs during SBOs. The criteria values for categorization were determined from the proposed systems, which could maintain a reactor in a safe state by removing the decay heat for the SBO coping time of 8 h. The

  15. Confirmation and efficacy tests against codling moth and oriental fruit moth in apples using combination heat and controlled atmosphere treatments.

    Science.gov (United States)

    Neven, Lisa G; Rehfield-Ray, Linda

    2006-10-01

    Codling moth, Cydia pomonella (L.), and oriental fruit moth, Grapholita molesta (Busck), are serious pests of apples (Malus spp.) grown in the United States and other countries. In countries where these species are not found, there are strict quarantine restrictions in place to prevent their accidental introduction. The treatment used in this study consisted of hot, forced, moist air with a linear heating rate of 12 degrees C/h to a final chamber temperature of 46 degrees C under a 1% oxygen and 15% carbon dioxide environment. We found that the fourth instar of both species was the most tolerant to the treatment, with equal tolerance between the species. Efficacy tests against the fourth instar of both oriental fruit moth and codling moth by using a commercial controlled atmosphere temperature treatment system chamber resulted in > 5,000 individuals of each species being controlled using the combination treatment. Confirmation tests against codling moth resulted in mortality of > 30,000 fourth instars. These treatments may be used to meet quarantine restrictions for organic apples where fumigation with methyl bromide is not desirable.

  16. Assessment of the Current Level of Automation in the Manufacture of Fuel Cell Systems for Combined Heat and Power Applications

    Energy Technology Data Exchange (ETDEWEB)

    Ulsh, M.; Wheeler, D.; Protopappas, P.

    2011-08-01

    The U.S. Department of Energy (DOE) is interested in supporting manufacturing research and development (R&D) for fuel cell systems in the 10-1,000 kilowatt (kW) power range relevant to stationary and distributed combined heat and power applications, with the intent to reduce manufacturing costs and increase production throughput. To assist in future decision-making, DOE requested that the National Renewable Energy Laboratory (NREL) provide a baseline understanding of the current levels of adoption of automation in manufacturing processes and flow, as well as of continuous processes. NREL identified and visited or interviewed key manufacturers, universities, and laboratories relevant to the study using a standard questionnaire. The questionnaire covered the current level of vertical integration, the importance of quality control developments for automation, the current level of automation and source of automation design, critical balance of plant issues, potential for continuous cell manufacturing, key manufacturing steps or processes that would benefit from DOE support for manufacturing R&D, the potential for cell or stack design changes to support automation, and the relationship between production volume and decisions on automation.

  17. Assessment of Potential Capacity Increases at Combined Heat and Power Facilities Based on Available Corn Stover and Forest Logging Residues

    Directory of Open Access Journals (Sweden)

    Donald L. Grebner

    2013-08-01

    Full Text Available Combined Heat and Power (CHP production using renewable energy sources is gaining importance because of its flexibility and high-energy efficiency. Biomass materials, such as corn stover and forestry residues, are potential sources for renewable energy for CHP production. In Mississippi, approximately 4.0 MT dry tons of woody biomass is available annually for energy production. In this study, we collected and analyzed 10 years of corn stover data (2001–2010 and three years of forest logging residue data (1995, 1999, and 2002 in each county in Mississippi to determine the potential of these feed stocks for sustainable CHP energy production. We identified six counties, namely Amite, Copiah, Clarke, Wayne, Wilkinson and Rankin, that have forest logging residue feedstocks to sustain a CHP facility with a range of capacity between 8.0 and 9.8 MW. Using corn stover alone, Yazoo and Washington counties can produce 13.4 MW and 13.5 MW of energy, respectively. Considering both feedstocks and based on a conservative amount of 30% available forest logging residue and 33% corn stover, we found that 20 counties have adequate supply for a CHP facility with a capacity of 8.3 MW to 19.6 MW.

  18. Nonablative skin tightening with a variable depth heating 1310-nm wavelength laser in combination with surface cooling.

    Science.gov (United States)

    Alexiades-Armenakas, Macrene

    2007-11-01

    A near-infrared laser with the ability to target different depths within skin has been developed and evaluated for the application of facial and neck skin tightening in a pilot clinical study. The device consists of a combination of a 1310-nm wavelength and sapphire contact cooling. Cooling temperature and laser pulse duration were varied to target different dermal depths in various subgroups of the subject population. Quantitative changes in various categories characterizing the aging skin employing a comprehensive grading scale as well as subject satisfaction were calculated. A mean improvement of 7.9% (95% CI [confidence interval] 3.6-12.3) in laxity and 10.6% (95% CI 5.8-15.4) in rhytides was determined by quantitative grading at one month after the treatment regimen. These values were 11.0% (5.5-16.5) and 11.7% (5.8-17.7) at 3 months after the treatment regimen. The percent of patients reporting mild or better improvement in laxity of the face and neck was 78% and 61% at one month, and 63% and 61% at 3 months, respectively. The discomfort was minimal. Side effects were limited to short-term erythema and edema. In summary, a variable depth heating laser can achieve skin tightening and wrinkle reduction with high subject satisfaction.

  19. Performance analysis of a direct expansion air dehumidification system combined with membrane-based total heat recovery

    Energy Technology Data Exchange (ETDEWEB)

    Liang, Cai-Hang; Zhang, Li-Zhi; Pei, Li-Xia [Key Laboratory of Enhanced Heat Transfer and Energy Conservation of Education Ministry, School of Chemistry and Chemical Engineering, South China University of Technology, Guangzhou 510640 (China)

    2010-09-15

    A direct expansion (DX) air dehumidification system is an efficient way to supply fresh and dry air to a built environment. It plays a key role in preventing the spread of respiratory disease like Swine flu (H1N1). To improve the efficiency of a conventional DX system in hot and humid regions, a new system of DX in combination with a membrane-based total heat exchanger is proposed. Air is supplied with dew points. A detailed mathematical modeling is performed. A cell-by-cell simulation technique is used to simulate its performances. A real prototype is built in our laboratory in South China University of Technology to validate the model. The effects of inlet air humidity and temperature, evaporator and condenser sizes on the system performance are investigated. The results indicate that the model can predict the system accurately. Compared to a conventional DX system, the air dehumidification rate (ADR) of the novel system is 0.5 times higher, and the coefficient of performance (COP) is 1 times higher. Furthermore, the system performs well even under harsh hot and humid weather conditions. (author)

  20. A Co-Powered Biomass and Concentrated Solar Power Rankine Cycle Concept for Small Size Combined Heat and Power Generation

    Directory of Open Access Journals (Sweden)

    Eileen Tortora

    2013-03-01

    Full Text Available The present work investigates the matching of an advanced small scale Combined Heat and Power (CHP Rankine cycle plant with end-user thermal and electric load. The power plant consists of a concentrated solar power field co-powered by a biomass furnace to produce steam in a Rankine cycle, with a CHP configuration. A hotel was selected as the end user due to its high thermal to electric consumption ratio. The power plant design and its operation were modelled and investigated by adopting transient simulations with an hourly distribution. The study of the load matching of the proposed renewable power technology and the final user has been carried out by comparing two different load tracking scenarios, i.e., the thermal and the electric demands. As a result, the power output follows fairly well the given load curves, supplying, on a selected winter day, about 50 GJ/d of thermal energy and the 6 GJ/d of electric energy, with reduced energy dumps when matching the load.

  1. Proton exchange membrane fuel cell for cooperating households: A convenient combined heat and power solution for residential applications

    International Nuclear Information System (INIS)

    Cappa, Francesco; Facci, Andrea Luigi; Ubertini, Stefano

    2015-01-01

    In this paper we compare the technical and economical performances of a high temperature proton exchange membrane fuel cell with those of an internal combustion engine for a 10 kW combined heat and power residential application. In a view of social innovation, this solution will create new partnerships of cooperating families aiming to reduce the energy consumption and costs. The energy system is simulated through a lumped model. We compare, in the Italian context, the total daily operating cost and energy savings of each system with respect to the separate purchase of electricity from the grid and production of the thermal energy through a standard boiler. The analysis is carried out with the energy systems operating with both the standard thermal tracking and an optimized management. The latter is retrieved through an optimization methodology based on the graph theory. We show that the internal combustion engine is much more affected by the choice of the operating strategy with respect to the fuel cell, in terms long term profitability. Then we conduct a net present value analysis with the aim of evidencing the convenience of using a high temperature proton exchange membrane fuel cell for cogeneration in residential applications. - Highlights: • Fuel cells are a feasible and economically convenient solution for residential CHP. • Control strategy is fundamental for the economical performance of a residential CHP. • Flexibility is a major strength of the fuel cell CHP.

  2. Combined natural convection and surface radiation in the annular region between a volumetrically heated inner tube and a finite conducting outer tube

    International Nuclear Information System (INIS)

    Gianoulakis, S.; Klein, D.E.

    1993-01-01

    Buoyancy-driven natural-convection heat transfer in enclosures has been the subject of considerable research with applications to electronic packaging, solar collectors, and shipping containers for spent nuclear fuel. A numerical study has been carried out to predict combined natural-convection and radiation heat transfer in the annular region between concentric tubes. The inner tube was volumetrically heated. Both tubes were of finite conductance. The surfaces of the annular region were diffuse and gray. The gas in the annulus was assumed to be nonparticipating. A newly developed hybrid finite element finite difference method was used for the study. This method combines finite element discretization of geometries with finite difference discretized solution procedures for the governing differential equations. This study examined the effects of surface radiative properties and material conductivities on the temperature and velocity fields and on local heat transfer rates. Fluid Raleigh numbers ranging from 10 3 to 10 7 , ratios of solid to fluid region thermal conductivities ranging from 10 to 10 4 , and surface total hemispherical emissivities ranging from 0.0 to 1.0 were examined in this study. It was found that the heat transfer across the annulus was dominated by conduction and radiation for the lower Raleigh number flows. As the fluid Raleigh number increased, convection became a primary mode of heat transfer. As the surface emissivity was increased in the annulus, the average Nusselt number on the inner tube surface decreased

  3. Energy Balance of Biogas Production from Microalgae: Effect of Harvesting Method, Multiple Raceways, Scale of Plant and Combined Heat and Power Generation

    Directory of Open Access Journals (Sweden)

    John J. Milledge

    2017-01-01

    Full Text Available A previously-developed mechanistic energy balance model for production of biogas from the anaerobic digestion of microalgal biomass grown in open raceway systems was used to consider the energetic viability of a number of scenarios, and to explore some of the most critical parameters affecting net energy production. The output demonstrated that no single harvesting method of those considered (centrifugation, settlement or flocculation produced an energy output sufficiently greater than operational energy inputs to make microalgal biogas production energetically viable. Combinations of harvesting methods could produce energy outputs 2.3–3.4 times greater than the operational energy inputs. Electrical energy to power pumps, mixers and harvesting systems was 5–8 times greater than the heating energy requirement. If the energy to power the plant is generated locally in a combined heat and power unit, a considerable amount of “low grade” heat will be available that is not required by the process, and for the system to show a net operational energy return this must be exploited. It is concluded that the production of microalgal biogas may be energetically viable, but it is dependent on the effective use of the heat generated by the combustion of biogas in combined heat and power units to show an operational energy return.

  4. An experimental study of the effects of combined exposure to microwave and heat on gene expression and sperm parameters in mice

    Directory of Open Access Journals (Sweden)

    Faezeh A Gohari

    2017-01-01

    Full Text Available Objectives: Separate exposure to microwaves (MWs or heat had effects on expression levels of Bax and Bcl-2 and sperm parameters in studied group. Aims: The objectives of this research were to determine the effects of separate and combined exposure to 900-MHz MW (as representative of cell phone radiation and heat on gene expression and spermogram of male mice. Settings and Design: This experimental animal study was conducted in the school of public health. Materials and Methods: The study was done on 12 male mice randomly divided into four groups (21–23 g: control, test group 1 with separate exposure to 900-MHz MW, test group 2 with separate exposure to hot and sultry climate, and test group 3 with simultaneous whole body exposures to 900-MHz MW and hot and sultry climate. In all studied groups, gene expression and sperm parameters were measured. Results: Tissue samples in all test groups showed integrity of the seminiferous tubule followed by all types of germ line cells. Significant increases in the number of dead sperms in mice with separate exposure to heat were observed in comparison with the other studied groups (P < 0.05. The ratio of Bax expression was elevated to 0.015 ± 0.006 in mice after combined exposures to 900-MHz MW and heat. Conclusion: Separate and combined exposure to 900-MHz MW and heat may induce adverse effects on sperm parameters and gene expression of studied male mice.

  5. Gross alpha and gross beta determination in surface and groundwater water by liquid scintillation counting (LSC)

    Energy Technology Data Exchange (ETDEWEB)

    Faria, Ligia S.; Moreira, Rubens M., E-mail: ligsfaria@gmail.com, E-mail: rubens@cdtn.br [Centro de Desenvolvimento da Tecnologia Nuclear (CDTN/CNEN-MG), Belo Horizonte, MG (Brazil)

    2013-07-01

    The present study has used 40 samples of groundwater and surface water collected at four different sites along the period of one year in Brumadinho and Nova Lima, two municipalities in the State of Minas Gerais, Brazil, as part of a more extensive study aiming at determination of the natural radioactivity in the water used for domestic use. These two sites are inside an Environmental Protection Area is located in a region of very intensive iron ore exploration. In addition of mineral resources, the region has a geological characteristic that includes quartzitic conglomerates associated with uranium. Radioactivity levels were determined via liquid scintillation counting (LSC), a fast and high counting efficiency method that can be advantageously employed to determine gross alpha and gross beta activity in liquid samples. Previously to gross alpha and gross beta counting the samples were acidified with concentrated HNO{sub 3} in the field. The technique involved a pre-concentration of the sample to obtain a low detection limit. Specific details of the employed methodology are commented. The results showed that concentrations of gross alpha natural activity and gross beta values ranged from less than the detection limit of the equipment (0.03 Bq.L{sup -1}) to 0.275 ± 0.05 Bq.L{sup -1} for gross alpha. As regards gross beta, all samples were below the limit of detection. (author)

  6. Combination of helical ferritic-steel inserts and flux-tube-expansion divertor for the heat control in tokamak DEMO reactor

    International Nuclear Information System (INIS)

    Takizuka, T.; Tokunaga, S.; Hoshino, K.; Shimizu, K.; Asakura, N.

    2015-01-01

    Edge localized modes (ELMs) in the H-mode operation of tokamak reactors may be suppressed/mitigated by the resonant magnetic perturbation (RMP), but RMP coils are considered incompatible with DEMO reactors under the strong neutron flux. We propose an innovative concept of the RMP without installing coils but inserting ferritic steels of the helical configuration. Helically perturbed field is naturally formed in the axisymmetric toroidal field through the helical ferritic steel inserts (FSIs). When ELMs are avoided, large stationary heat load on divertor plates can be reduced by adopting a flux-tube-expansion (FTE) divertor like an X divertor. Separatrix shape and divertor-plate inclination are similar to those of a simple long-leg divertor configuration. Combination of the helical FSIs and the FTE divertor is a suitable method for the heat control to avoid transient ELM heat pulse and to reduce stationary divertor heat load in a tokamak DEMO reactor

  7. Agent-Based Control of Distributed Electricity Generation with Micro Combined Heat and Power : Cross-Sectoral Learning for Process and Infrastructure Engineers

    NARCIS (Netherlands)

    Van Dam, K.H.; Houwing, M.; Lukszo, Z.; Bouwmans, I.

    2007-01-01

    For the distributed control of an electricity infrastructure incorporating clusters of residential combined heat and power units (micro-CHP or ?CHP) a Multi-Agent System approach is considered. The network formed by households generating electricity with ?CHP units and the facilitating energy

  8. ANALYSIS OF THE IMPACT PROPERTIES OF THE COOLANT RECOVERY SYSTEM HEAT LOSSES OF COMBINED COMPRESSOR-POWER PLANT ON ITS CHARACTERISTICS

    OpenAIRE

    Yusha V.L.; Chernov G.; Raykovsky N.

    2012-01-01

    The paper presents results of theoretical analysis of the effectiveness of an ideal thermodynamic cycle internal combustion engine combined with an external utilization of exhaust heat. The influence of the properties of the coolant circuit of utilization on its operational parameters and characteristics of the power plant.

  9. Business management advantages for industrial processes with combined heat and power systems. Betriebswirtschaftliche Vorteile fuer industrielle Prozesse durch Kraft-Waerme-Kopplungssysteme

    Energy Technology Data Exchange (ETDEWEB)

    Paulusch, R.; Kiessling, K. (SKL Industrieanlagen, Magdeburg (Germany))

    1992-10-01

    The combination of power and heat gains even additional efficiency when included in industrial processes. Which possibilities do exist are verified by the authors by means of examples for the following technological processes: Recycling processes, disposal procedures, mineral oil refining processes, gas purification procedures. (orig.).

  10. ANALYSIS OF THE IMPACT PROPERTIES OF THE COOLANT RECOVERY SYSTEM HEAT LOSSES OF COMBINED COMPRESSOR-POWER PLANT ON ITS CHARACTERISTICS

    Directory of Open Access Journals (Sweden)

    Yusha V.L.

    2012-12-01

    Full Text Available The paper presents results of theoretical analysis of the effectiveness of an ideal thermodynamic cycle internal combustion engine combined with an external utilization of exhaust heat. The influence of the properties of the coolant circuit of utilization on its operational parameters and characteristics of the power plant.

  11. Environmental implications of carbon limits on market penetration of combined heat and power with the U.S. energy sector (Slides)

    Science.gov (United States)

    Combined heat and power (CHP) is promoted as an economical, energy-efficient option for combating climate change. To fully examine the viability of CHP as a clean-technology solution, its market potential and impacts need to be analyzed as part of scenarios of the future energy s...

  12. Energy Smart Guide to Campus Cost Savings: Today's Trends in Project Finance, Clean Fuel Fleets, Combined Heat& Power, Emissions Markets

    Energy Technology Data Exchange (ETDEWEB)

    2003-07-01

    The Energy Smart Guide to Campus Cost Savings covers today's trends in project finance, combined heat& power, clean fuel fleets and emissions trading. The guide is directed at campus facilities and business managers and contains general guidance, contact information and case studies from colleges and universities across the country.

  13. The CO2 Reduction Potential of Combined Heat and Power in California's Commercial Buildings

    Energy Technology Data Exchange (ETDEWEB)

    Stadler, Michael; Marnay, Chris; Cardoso, Goncalo; Lipman, Tim; Megel, Olivier; Ganguly, Srirupa; Siddiqui, Afzal; Lai, Judy

    2009-11-16

    The Ernest Orlando Lawrence Berkeley National Laboratory (LBNL) is working with the California Energy Commission (CEC) to determine the potential role of commercial sector distributed generation (DG) with combined heat and power (CHP) capability deployment in greenhouse gas emissions (GHG) reductions. CHP applications at large industrial sites are well known, and a large share of their potential has already been harvested. In contrast, relatively little attention has been paid to the potential of medium-sized commercial buildings, i.e., ones with peak electric loads ranging from 100 kW to 5 MW. We examine how this sector might implement DG with CHP in cost minimizing microgrids that are able to adopt and operate various energy technologies, such as solar photovoltaics (PV), on-site thermal generation, heat exchangers, solar thermal collectors, absorption chillers, and storage systems. We apply a mixed-integer linear program (MILP) that minimizes a site's annual energy costs as its objective. Using 138 representative mid-sized commercial sites in California (CA), existing tariffs of three major electricity distribution ultilities plus a natural gas company, and performance data of available technology in 2020, we find the GHG reduction potential for this CA commercial sector segment, which represents about 35percent of total statewide commercial sector sales. Under the assumptions made, in a reference case, this segment is estimated to be capable of economically installing 1.4 GW of CHP, 35percent of the California Air Resources Board (CARB) statewide 4 GW goal for total incremental CHP deployment by 2020. However, because CARB's assumed utilization is far higherthan is found by the MILP, the adopted CHP only contributes 19percent of the CO2 target. Several sensitivity runs were completed. One applies a simple feed-in tariff similar to net metering, and another includes a generous self-generation incentive program (SGIP) subsidy for fuel cells. The feed

  14. Mathematical modelling and optimization of a large-scale combined cooling, heat, and power system that incorporates unit changeover and time-of-use electricity price

    International Nuclear Information System (INIS)

    Zhu, Qiannan; Luo, Xianglong; Zhang, Bingjian; Chen, Ying

    2017-01-01

    Highlights: • We propose a novel superstructure for the design and optimization of LSCCHP. • A multi-objective multi-period MINLP model is formulated. • The unit start-up cost and time-of-use electricity prices are involved. • Unit size discretization strategy is proposed to linearize the original MINLP model. • A case study is elaborated to demonstrate the effectiveness of the proposed method. - Abstract: Building energy systems, particularly large public ones, are major energy consumers and pollutant emission contributors. In this study, a superstructure of large-scale combined cooling, heat, and power system is constructed. The off-design unit, economic cost, and CO 2 emission models are also formulated. Moreover, a multi-objective mixed integer nonlinear programming model is formulated for the simultaneous system synthesis, technology selection, unit sizing, and operation optimization of large-scale combined cooling, heat, and power system. Time-of-use electricity price and unit changeover cost are incorporated into the problem model. The economic objective is to minimize the total annual cost, which comprises the operation and investment costs of large-scale combined cooling, heat, and power system. The environmental objective is to minimize the annual global CO 2 emission of large-scale combined cooling, heat, and power system. The augmented ε–constraint method is applied to achieve the Pareto frontier of the design configuration, thereby reflecting the set of solutions that represent optimal trade-offs between the economic and environmental objectives. Sensitivity analysis is conducted to reflect the impact of natural gas price on the combined cooling, heat, and power system. The synthesis and design of combined cooling, heat, and power system for an airport in China is studied to test the proposed synthesis and design methodology. The Pareto curve of multi-objective optimization shows that the total annual cost varies from 102.53 to 94.59 M

  15. Experimental study of the combined utilization of nuclear power heating plants for big towns and industrial complexes

    International Nuclear Information System (INIS)

    Neumann, J.; Barabas, K.

    1977-01-01

    The paper describes a comparison of nuclear power heating plants with an output corresponding to 1000MW(e) with plants of the same output using coal or oil. The economic aspects are compared, both as regards investment and operation costs. The comparison of the environmental aspects is performed on the atmospheric pollution from exhausts and gaseous emission and on the thermal pollutions in hydrosphere and atmosphere. Basic nuclear power plant schemes with two PWRs, each of 1500MW(th), are described. The plant supplies electric power and heat for factories and municipal heating systems (apartments, shops, and other auxiliary municipal facilities). At the same time the basic heat-flow diagram of a nuclear power heating plant is given, together with the relative losses. The study emphasizes the possible utilization of waste heat for heating glasshouses of 200m 2 . The problems of utilizing waste heat, and the needs of a big town and of industrial complexes in the vicinity of the nuclear power heating plant are also considered. (author)

  16. 26 CFR 1.61-1 - Gross income.

    Science.gov (United States)

    2010-04-01

    ... TAXES (CONTINUED) Definition of Gross Income, Adjusted Gross Income, and Taxable Income § 1.61-1 Gross income. (a) General definition. Gross income means all income from whatever source derived, unless.... Income may be realized, therefore, in the form of services, meals, accommodations, stock, or other...

  17. Thermoeconomic Modeling and Parametric Study of a Photovoltaic-Assisted 1 MWe Combined Cooling, Heating, and Power System

    Directory of Open Access Journals (Sweden)

    Alexandros Arsalis

    2016-08-01

    Full Text Available In this study a small-scale, completely autonomous combined cooling, heating, and power (CCHP system is coupled to a photovoltaic (PV subsystem, to investigate the possibility of reducing fuel consumption. The CCHP system generates electrical energy with the use of a simple gas turbine cycle, with a rated nominal power output of 1 MWe. The nominal power output of the PV subsystem is examined in a parametric study, ranging from 0 to 600 kWe, to investigate which configuration results in a minimum lifecycle cost (LCC for a system lifetime of 20 years of service. The load profile considered is applied for a complex of households in Nicosia, Cyprus. The solar data for the PV subsystem are taken on an hourly basis for a whole year. The results suggest that apart from economic benefits, the proposed system also results in high efficiency and reduced CO2 emissions. The parametric study shows that the optimum PV capacity is 300 kWe. The minimum lifecycle cost for the PV-assisted CCHP system is found to be 3.509 million €, as compared to 3.577 million € for a system without a PV subsystem. The total cost for the PV subsystem is 547,445 €, while the total cost for operating the system (fuel is 731,814 € (compared to 952,201 € for a CCHP system without PVs. Overall the proposed system generates a total energy output of 210,520 kWh (during its whole lifetime, which translates to a unit cost of 17 €/kWh.

  18. Performance of U.S. hybrid distributed energy systems: Solar photovoltaic, battery and combined heat and power

    International Nuclear Information System (INIS)

    Shah, Kunal K.; Mundada, Aishwarya S.; Pearce, J.M.

    2015-01-01

    Highlights: • Simulated PV + battery + CHP hybrid systems deployed in three U.S. regions. • Used hybrid optimization model for electric renewable pro microgrid analysis. • Limited size of each sub-module to singe family house size. • Results show that the electricity generated meets residential load demand. • Hybrid systems are technically viable in hot, moderate and cold climates in U.S. - Abstract: Until recently, the relatively high levelized cost of electricity from solar photovoltaic (PV) technology limited deployment; however, recent cost reductions, combined with various financial incentives and innovative financing techniques, have made PV fully competitive with conventional sources in many American regions. In addition, the costs of electrical storage have also declined enough to make PV + battery systems potentially economically viable for a mass-scale off-grid low-emission transition. However, many regions in the U.S. (e.g. Northern areas) cannot have off-grid PV systems without prohibitively large battery systems. Small-scale combined heat and power (CHP) systems provide a potential solution for off-grid power backup of residential-scale PV + battery arrays, while also minimizing emissions from conventional sources. Thus, an opportunity is now available to maximize the use of solar energy and gain the improved efficiencies possible with CHPs to deploy PV + battery + CHP systems throughout the U.S. The aim of this study is to determine the technical viability of such systems by simulating PV + battery + CHP hybrid systems deployed in three representative regions in the U.S., using the Hybrid Optimization Model for Electric Renewable (HOMER) Pro Microgrid Analysis tool. The results show that the electricity generated by each component of the hybrid system can be coupled to fulfill the residential load demand. A sensitivity analysis of these hybrid off grid systems is carried out as a function capacity factor of both the PV and CHP units. The

  19. Power and Efficiency Analysis of a Solar Central Receiver Combined Cycle Plant with a Small Particle Heat Exchanger Receiver

    Science.gov (United States)

    Virgen, Matthew Miguel

    Two significant goals in solar plant operation are lower cost and higher efficiencies. To achieve those goals, a combined cycle gas turbine (CCGT) system, which uses the hot gas turbine exhaust to produce superheated steam for a bottoming Rankine cycle by way of a heat recovery steam generator (HRSG), is investigated in this work. Building off of a previous gas turbine model created at the Combustion and Solar Energy Laboratory at SDSU, here are added the HRSG and steam turbine model, which had to handle significant change in the mass flow and temperature of air exiting the gas turbine due to varying solar input. A wide range of cases were run to explore options for maximizing both power and efficiency from the proposed CSP CCGT plant. Variable guide vanes (VGVs) were found in the earlier model to be an effective tool in providing operational flexibility to address the variable nature of solar input. Combined cycle efficiencies in the range of 50% were found to result from this plant configuration. However, a combustor inlet temperature (CIT) limit leads to two distinct Modes of operation, with a sharp drop in both plant efficiency and power occurring when the air flow through the receiver exceeded the CIT limit. This drawback can be partially addressed through strategic use of the VGVs. Since system response is fully established for the relevant range of solar input and variable guide vane angles, the System Advisor Model (SAM) from NREL can be used to find what the actual expected solar input would be over the course of the day, and plan accordingly. While the SAM software is not yet equipped to model a Brayton cycle cavity receiver, appropriate approximations were made in order to produce a suitable heliostat field to fit this system. Since the SPHER uses carbon nano-particles as the solar absorbers, questions of particle longevity and how the particles might affect the flame behavior in the combustor were addressed using the chemical kinetics software Chemkin

  20. Development of Natural Gas Fired Combined Cycle Plant for Tri-Generation of Power, Cooling and Clean Water Using Waste Heat Recovery: Techno-Economic Analysis

    Directory of Open Access Journals (Sweden)

    Gowtham Mohan

    2014-10-01

    Full Text Available Tri-generation is one of the most efficient ways for maximizing the utilization of available energy. Utilization of waste heat (flue gases liberated by the Al-Hamra gas turbine power plant is analyzed in this research work for simultaneous production of: (a electricity by combining steam rankine cycle using heat recovery steam generator (HRSG; (b clean water by air gap membrane distillation (AGMD plant; and (c cooling by single stage vapor absorption chiller (VAC. The flue gases liberated from the gas turbine power cycle is the prime source of energy for the tri-generation system. The heat recovered from condenser of steam cycle and excess heat available at the flue gases are utilized to drive cooling and desalination cycles which are optimized based on the cooling energy demands of the villas. Economic and environmental benefits of the tri-generation system in terms of cost savings and reduction in carbon emissions were analyzed. Energy efficiency of about 82%–85% is achieved by the tri-generation system compared to 50%–52% for combined cycles. Normalized carbon dioxide emission per MW·h is reduced by 51.5% by implementation of waste heat recovery tri-generation system. The tri-generation system has a payback period of 1.38 years with cumulative net present value of $66 million over the project life time.

  1. Determination of gross energy of silages

    Directory of Open Access Journals (Sweden)

    G. Meineri

    2010-01-01

    Full Text Available The gross energy (GE of forage is not directly used in rationing systems, but its evaluation is the starting point for an estimate of the digestible, metabolisable and net energy. As far as grass silages are concerned, their GE is 4 to 10% higher that of the grass source.

  2. Dynamic Relationship Between Gross Domestic Product and ...

    African Journals Online (AJOL)

    This study uses a VAR model to analyse the dynamic relationship between gross domestic product (GDP) and domestic investment (DI) in Rwanda for the period 1970 to 2011. Several selection lag criteria chose a maximum lag of one and a bivariate VAR(1) model specification in levels was adopted. Unit root tests show ...

  3. Alternative Measure of Wellbeing: Bhutan's Gross National ...

    International Development Research Centre (IDRC) Digital Library (Canada)

    In 2008, the Centre for Bhutan Studies - Bhutan's main policy research centre - posted data from a preliminary survey of the country's Gross National Happiness (GNH). The Centre ... The global financial crisis of 2008 has aggravated poverty and inequality through contractions in employment, consumption and investment.

  4. Integrating multiple stressors across life stages and latitudes: Combined and delayed effects of an egg heat wave and larval pesticide exposure in a damselfly.

    Science.gov (United States)

    Sniegula, Szymon; Janssens, Lizanne; Stoks, Robby

    2017-05-01

    To understand the effects of pollutants in a changing world we need multistressor studies that combine pollutants with other stressors associated with global change such as heat waves. We tested for the delayed and combined impact of a heat wave during the egg stage and subsequent sublethal exposure to the pesticide esfenvalerate during the larval stage on life history and physiology in the larval and adult stage of the damselfly Lestes sponsa. We studied this in a common garden experiment with replicated central- and high latitude populations to explore potential effects of local thermal adaptation and differences in life history shaping the multistressor responses. Exposure of eggs to the heat wave had no effect on larval traits, yet had delayed costs (lower fat and flight muscle mass) in the adult stage thereby crossing two life history transitions. These delayed costs were only present in central-latitude populations potentially indicating their lower heat tolerance. Exposure of larvae to the pesticide reduced larval growth rate and prolonged development time, and across metamorphosis reduced the adult fat content and the flight muscle mass, yet did not affect the adult heat tolerance. The pesticide-induced delayed emergence was only present in the slower growing central-latitude larvae, possibly reflecting stronger selection to keep development fast in the more time-constrained high-latitude populations. We observed no synergistic interactions between the egg heat wave and the larval pesticide exposure. Instead the pesticide-induced reduction in fat content was only present in animals that were not exposed to the egg heat wave. Our results based on laboratory conditions highlight that multistressor studies should integrate across life stages to fully capture cumulative effects of pollutants with other stressors related to global change. Copyright © 2017 Elsevier B.V. All rights reserved.

  5. Estimation of delayed neutron emission probability by using the gross theory of nuclear β-decay

    International Nuclear Information System (INIS)

    Tachibana, Takahiro

    1999-01-01

    The delayed neutron emission probabilities (P n -values) of fission products are necessary in the study of reactor physics; e.g. in the calculation of total delayed neutron yields and in the summation calculation of decay heat. In this report, the P n -values estimated by the gross theory for some fission products are compared with experiment, and it is found that, on the average, the semi-gross theory somewhat underestimates the experimental P n -values. A modification of the β-decay strength function is briefly discussed to get more reasonable P n -values. (author)

  6. Combined natural convection and mass transfer effects on unsteady flow past an infinite vertical porous plate embedded in a porous medium with heat source

    Energy Technology Data Exchange (ETDEWEB)

    Das, S.S. [Department of Physics, K B D A V College, Nirakarpur, Khurda-752 019 (Orissa) (India); Tripathy, R.K. [Department of Physics, D R Nayapalli College, Bhubaneswar-751 012 (Orissa) (India); Padhy, R.K. [Department of Physics, D A V Public School, Chandrasekharpur, Bhubaneswar-751 021 (Orissa) (India); Sahu, M. [Department of Physics, Jupiter +2 Women’s Science College, IRC Village, Bhubaneswar-751 015 (Orissa) (India)

    2012-07-01

    This paper theoretically investigates the combined natural convection and mass transfer effects on unsteady flow of a viscous incompressible fluid past an infinite vertical porous plate embedded in a porous medium with heat source. The governing equations of the flow field are solved analytically for velocity, temperature, concentration distribution, skin friction and the rate of heat transfer using multi parameter perturbation technique and the effects of the flow parameters such as permeability parameter Kp, Grashof number for heat and mass transfer Gr, Gc; heat source parameter S, Schmidt number Sc, Prandtl number Pr etc. on the flow field are analyzed and discussed with the help of figures and tables. The permeability parameter Kp is reported to accelerate the transient velocity of the flow field at all points for small values of Kp (£1) and for higher values the effect reverses. The effect of increasing Grashof numbers for heat and mass transfer or heat source parameter is to enhance the transient velocity of the flow field at all points while a growing Schmidt number retards its effect at all points. A growing permeability parameter or heat source parameter increases the transient temperature of the flow field at all points, while a growing Prandtl number shows reverse effect. The effect of increasing Schmidt number is to decrease the concentration boundary layer thickness of the flow field at all points. Further, a growing permeability parameter enhances the skin friction at the wall and a growing Prandtl number shows reverse effect. The effect of increasing Prandtl number or permeability parameter leads to increase the magnitude of the rate of heat transfer at the wall.

  7. CO{sub 2} reduction: potential of heat pumps when used together with combined heat and power units; Potentiel energetique des pompes a chaleur combinees au couplage chaleur-force. Pour une reduction maximale des emissions de CO{sub 2} et pour une production de courant fossile avec reduction des emissions de CO{sub 2} en Suisse - Rapport final

    Energy Technology Data Exchange (ETDEWEB)

    Rognon, F.

    2005-07-01

    This final report for the Swiss Federal Office of Energy (SFOE) presents the results of a project that examined the potential of using heat pumps in combination with Combined Heat and Power (CHP) units as a replacement for fossil-fuel fired heating units in Switzerland. The electrical power produced by the CHP units can be used to provide power for the drives of heat pump systems. The author states that the fossil fuel consumption and the resulting emissions of carbon dioxide can be halved using this combination. Also, even more efficient systems using power produced in larger combined-cycle power generation are discussed. Further examples of how fossil-fired power generation in combination with heat pumps can not only replace fossil-fuelled heating systems but also provide additional electricity too are given. This overview includes figures on the potential of such combined systems.

  8. Inactivation of Escherichia coli O157:H7 in fruit juices by combined treatments of citrus fruit essential oils and heat.

    Science.gov (United States)

    Espina, Laura; Somolinos, María; Ouazzou, Abdenour Ait; Condón, Santiago; García-Gonzalo, Diego; Pagán, Rafael

    2012-09-17

    This work approaches the possibility of combining mild heat treatments with citrus fruit essential oils (EOs) to improve the effectiveness of heat treatments and thus to reduce treatment intensity. Concentrations between 10 and 200 μL/L of lemon, mandarin, or orange EO were tested at 54 °C for 10 min in laboratory media, determining that 200 μL/L of each EO was necessary to achieve a 5 log(10) reduction of the initial Escherichia coli O157:H7 concentration. A relationship could be established between sublethally injured cells after the heat treatment and inactivated cells after the combined process. In apple juice, the synergism in the inactivation of E. coli O157:H7 when adding 200 μL/L of lemon EO might suppose a reduction in the treatment temperature (of 4.5 °C) or in the treatment time (by 5.7 times) within the range of temperature assayed (54-60 °C). Addition of 75 μL/L of lemon EO was determined to achieve the same synergistic effect of the combined treatment when the initial inoculum was reduced from 3×10(7) to 3×10(4) CFU/mL. Since the addition of lemon EO did not decrease the hedonic acceptability of apple juice, the proposed combined treatment could be further studied and optimized for the production of new minimally processed juices. Copyright © 2012 Elsevier B.V. All rights reserved.

  9. Combined Active and Passive Solar Space Heating and Solar Hot Water Systems for an Elementary School in Boise, Idaho.

    Science.gov (United States)

    Smull, Neil A.; Armstrong, Gerald L.

    1979-01-01

    Amity Elementary School in Boise, Idaho, features a solar space heating and domestic hot water system along with an earth covering to accommodate the passive aspects of energy conservation. (Author/MLF)

  10. A numerical study of magnetohydrodynamics flow in Casson nanofluid combined with Joule heating and slip boundary conditions

    Directory of Open Access Journals (Sweden)

    A. Kamran

    Full Text Available A numerical study of Casson nanofluid past horizontal stretching surface with magnetic effect and Joule heating are presented. Slip and thermal convective boundary conditions are considered in the study. A numerical technique of Keller box is applied to the nonlinear ODEs which are obtained by applying the similarity transformation to the nonlinear partial differential equations. The magnetic field and Joule heating effects are observed graphically. Also the strength of convective heat exchange (Nusselt number and the strength of mass exchange (Sherwood number are analyzed. It is noted that Nusselt number declines whereas Sherwood number rises by increasing Eckert number. The impact of increasing Hartman number resulted in the decrease of both Sherwood and Nusselt number. Keywords: Casson nanofluid, Magnetohydrodynamic, Joule heating, Keller box method

  11. Winner of the Lund Science Award 1992. Thermosensitization induced by step-down heating. A review on heat-induced sensitization to hyperthermia alone or hyperthermia combined with radiation.

    Science.gov (United States)

    Lindegaard, J C

    1992-01-01

    A few minute's exposure to a high temperature (sensitizing treatment, ST) may substantially increase the cytotoxic and the radiosensitizing effect of a subsequent heating at a lower temperature (test treatment, TT). This phenomenon, which is known as step-down heating (SDH) or thermosensitization, has been observed both in cultured cells in vitro and in tumours and normal tissues in vivo. The effect of SDH increases with a lowering of TT temperature, but it is rapidly lost at temperatures very close to 37 degrees C. SDH-induced thermosensitization decays within a few hours, when an interval is inserted between ST and TT. In vitro results suggest an exponential decay of the SDH effect with half times ranging from 1.5- to 3.1 h. The effect of SDH increases with increasing ST time or temperature. For single heating, the Arrhenius plot is biphasic with activation energies of 500-800 and 1200-1700 kJ/mol above and below a break point temperature in the region 42.5-43.0 degrees C, respectively. For SDH, the Arrhenius plot gradually becomes monophasic with increasing severity of ST and it approaches asymptotically to an activation energy of about 400 kJ/mol. The reduction of the activation energy depends on cell survival after the priming ST and not on the specific ST heating time or temperature. SDH strongly enhances hyperthermic radiosensitization with a 5-6-fold reduction of the radiation dose required to achieve tumour control. The thermosensitizing and the radiosensitizing effects of SDH have several features in common. Both effects become more prominent when the TT temperature is decreased and when the ST heating time or temperature increases. In addition, the decay kinetics for both effects are comparable. For heat alone, the effect of SDH in tumour and normal tissue seems to be quantitatively similar. However, the therapeutic ratio may be increased by combining SDH with radiation. Biologically, the critical subcellular targets involved in the SDH effect have not

  12. Monitoring of gross alpha, gross beta and tritium activities in portuguese drinking waters

    Energy Technology Data Exchange (ETDEWEB)

    Lopes, I.; Madruga, M.J.; Ferrador, G.O.; Sequeira, M.M.; Oliveira, E.J.; Gomes, A.R.; Rodrigues, F.D.; Carvalho, F.P. [Nuclear and Technological Institute/Dep. of Radiological Protection and Nuclear Safety (Portugal)

    2006-07-01

    The gross bend tritium activities in the forty Portuguese drinking waters analyzed using the ISO standard methods (Portuguese Guidelines) are below the guidance levels proposed in the Portuguese Drinking Water Quality Guidelines. In what concerns the gross alpha activity only 18% exceeded the recommended level. In general, it can be concluded that the ingestion of these drinking waters does not create a radiological hazard to the human consumption, however, more detailed analyses will be necessary mainly the determinations of the individual alpha emitters radionuclide concentrations. The minimum gross alpha and gross beta detectable activities by L.S.C. methodology are higher than for the proportional counting technique (ISO method). Higher concentration factors will be needed to reach lower required detection limits. (authors)

  13. Monitoring of gross alpha, gross beta and tritium activities in portuguese drinking waters

    International Nuclear Information System (INIS)

    Lopes, I.; Madruga, M.J.; Ferrador, G.O.; Sequeira, M.M.; Oliveira, E.J.; Gomes, A.R.; Rodrigues, F.D.; Carvalho, F.P.

    2006-01-01

    The gross beta and tritium activities in the forty Portuguese drinking waters analyzed using the ISO standard methods (Portuguese Guidelines) are below the guidance levels proposed in the Portuguese Drinking Water Quality Guidelines. In what concerns the gross alpha activity only 18% exceeded the recommended level. In general, it can be concluded that the ingestion of these drinking waters does not create a radiological hazard to the human consumption, however, more detailed analyses will be necessary mainly the determinations of the individual alpha emitters radionuclide concentrations. The minimum gross alpha and gross beta detectable activities by L.S.C. methodology are higher than for the proportional counting technique (ISO method). Higher concentration factors will be needed to reach lower required detection limits. (authors)

  14. Conjugate Heat Transfer Study at Interior Surface of NGV Leading Edge with Combined Shower Head and Impingement Cooling

    OpenAIRE

    Arun Kumar Pujari; B. V. S. S. S. Prasad; N. Sitaram

    2014-01-01

    A computational study on conjugate heat transfer is carried out to present the behavior of nondimensional temperature and heat transfer coefficient of a Nozzle Guide Vane (NGV) leading edge. Reynolds number of both mainstream flow and coolant impinging jets are varied. The NGV has five rows of film cooling holes arranged in shower head manner and four rows of impingement holes arranged in staggered manner. The results are presented by considering materials of different thermal conductivity. T...

  15. Experimental Study of Air Distribution and Ventilation Effectiveness in a Room with a Combination of Different Mechanical Ventilation and Heating/Cooling Systems

    DEFF Research Database (Denmark)

    Olesen, Bjarne W.; Simone, Angela; Krajcik, Michal

    2011-01-01

    Mixing and displacement ventilation are common systems in commercial buildings, while mixing ventilation is used in residential buildings. Displacement ventilation provides fresh air to the occupied zone in a more efficient way than mixing ventilation but it is important to know how well it works...... with a floor system for heating or cooling. Can, for example, a floor heating system warm up the supply air too fast and destroy the displacement effect? Will floor cooling, combined with displacement ventilation, result in too high a vertical temperature difference and too low a temperature at feet level......? The required amount of ventilation depends on the ventilation effectiveness. In standards, the recommended values for ventilation effectiveness depend on the position of the supply and exhaust device and on the difference between supply and room air temperature. Among others, for warm air heating...

  16. Comparative analysis of cooling systems for energy equipment of combined heat and power plants and nuclear power plants

    Science.gov (United States)

    Reutov, B. F.; Lazarev, M. V.; Ermakova, S. V.; Zisman, S. L.; Kaplanovich, L. S.; Svetushkov, V. V.

    2016-07-01

    In the 20th century, the thermal power engineering in this country was oriented toward oncethrough cooling systems. More than 50% of the CHPP and NPP capacities with once-through cooling systems put into operation before the 1990s were large-scale water consumers but with minimum irretrievable water consumption. In 1995, the Water Code of the Russian Federation was adopted in which restrictions on application of once-through cooling systems for newly designed combined heat and power plants (CHPPs) were introduced for the first time. A ban on application of once-through systems was imposed by the current Water Code of the Russian Federation (Federal law no. 74-FZ, Art. 60 Cl. 4) not only for new CHPPs but also for those to be modified. Clause 4 of Article 60 of the Water Code of the Russian Federation contravenes law no. 7-FZ "On Protection of the Environment" that has priority significance, since the water environment is only part of the natural environment and those articles of the Water Code of the Russian Federation that are related directly to electric power engineering, viz., Articles 46 and 62. In recent decades, the search for means to increase revenue charges and the economic pressure on the thermal power industry caused introduction by law of charges for use of water by cooling systems irrespective of the latter's impact on the water quality of the source, the environment, the economic efficiency of the power production, and the living conditions of the people. The long-range annual increase in the water use charges forces the power generating companies to switch transfer once-through service water supply installations to recirculating water supply systems and once-through-recirculating systems with multiple reuse of warm water, which drastically reduces the technical, economic, and ecological characteristic of the power plant operation and also results in increasing power rates for the population. This work comprehensively substantiates the demands of

  17. Effects of steam pretreatment and co-production with ethanol on the energy efficiency and process economics of combined biogas, heat and electricity production from industrial hemp

    Science.gov (United States)

    2013-01-01

    Background The study presented here has used the commercial flow sheeting program Aspen Plus™ to evaluate techno-economic aspects of large-scale hemp-based processes for producing transportation fuels. The co-production of biogas, district heat and power from chopped and steam-pretreated hemp, and the co-production of ethanol, biogas, heat and power from steam-pretreated hemp were analysed. The analyses include assessments of heat demand, energy efficiency and process economics in terms of annual cash flows and minimum biogas and ethanol selling prices (MBSP and MESP). Results Producing biogas, heat and power from chopped hemp has the highest overall energy efficiency, 84% of the theoretical maximum (based on lower heating values), providing that the maximum capacity of district heat is delivered. The combined production of ethanol, biogas, heat and power has the highest energy efficiency (49%) if district heat is not produced. Neither the inclusion of steam pretreatment nor co-production with ethanol has a large impact on the MBSP. Ethanol is more expensive to produce than biogas is, but this is compensated for by its higher market price. None of the scenarios examined are economically viable, since the MBSP (EUR 103–128 per MWh) is higher than the market price of biogas (EUR 67 per MWh). The largest contribution to the cost is the cost of feedstock. Decreasing the retention time in the biogas process for low solids streams by partly replacing continuous stirred tank reactors by high-rate bioreactors decreases the MBSP. Also, recycling part of the liquid from the effluent from anaerobic digestion decreases the MBSP. The production and prices of methane and ethanol influence the process economics more than the production and prices of electricity and district heat. Conclusions To reduce the production cost of ethanol and biogas from biomass, the use of feedstocks that are cheaper than hemp, give higher output of ethanol and biogas, or combined production with

  18. Administration of extract Salix tetrasperma combined with extract of turmeric and neem to improve eggs quality of chicken reared under heat stress

    Directory of Open Access Journals (Sweden)

    Sugito

    2015-09-01

    Full Text Available Quality of eggs might decrease when hens under heat stress. A further study found that a specific plant extracts could reduce the impacts of heat stress. The aim of this study was to determine effects of Salix tetrasperma plant extract in combination with extract of turmeric and neem to improve egg quality and productivity of laying hens under heat stress. Sixty laying hens strain Isa Brown of 6 months old were used and reared in individual cages. The feed and drinking water were supplied ad libitum. This study was conducted in a completely randomized design with five treatments (two controls and three treatments and each treatment consisted of 12 replication. Treatment consisted of with (KP and without (KP commercial anti-stress supplement. Formulations of extract were S. tetrasperma 1.000 mg / l water (EJ, S. tetrasperma 1.000 mg / l + Turmeric 250 mg / l + neem 250 mg / l (EJ+K1, and S. tetrasperma 1.000 mg / l + Turmeric 500 mg / l + neem 500 mg / l drinking water (EJ+K2. The hens were exposed to heat stress for 5 hours per day at a temperature range of 34.0±1.0°C. Supplements were dissolved in drinking water and were given for 30 days in the morning and noon. Results showed that a single extract of S. tetrasperma or the combination of an extract of turmeric and neem were significantly increased thickness of eggshell (P<0.05, but did not affect color of egg yolk, height albumin, egg weight, and HU value. Extract of S. tetrasperma combined with turmeric and neem extract dissolved in drinking water for 30 days in laying hens reared under heat stress could not improved quality of the eggs, but may increase thickness of the egg shell and cause decreased water consumption.

  19. Effectiveness of edible coatings combined with mild heat shocks on microbial spoilage and sensory quality of fresh cut broccoli (Brassica oleracea L.).

    Science.gov (United States)

    Moreira, María del R; Ponce, Alejandra; Ansorena, R; Roura, Sara I

    2011-08-01

    The use of edible coatings and mild heat shocks is proposed as postharvest treatments to prevent microbial deterioration of refrigerated broccoli. Minimally processed broccoli was coated with either chitosan or carboxymethyl-cellulose (CMC) combined or not with a previous application of a mild heat shock. The evolution of microbial populations (mesophilic, psycrotrophic, Enterobacteriaceae, molds and yeast, and lactic acid bacteria) was studied during 20 d of storage and fitted to Gompertz and logistic models. Results revealed that, at the end of the storage, chitosan coating significantly reduced all microbiological population counts, except lactic acid bacteria; while higher reduction was observed with chitosan coating combined with a heat shock treatment. A significant delay at the beginning of the exponential phase was observed for all the bacterial populations analyzed. On the other hand, CMC coating, with and without a previous thermal treatment, did not exert any antibacterial effect. Excellent agreement was found between experimental microbial counts and predicted values obtained from Gompertz and logistic models. Kinetic modeling was found to be valuable for prediction of microbiological shelf life of broccoli during storage. Results showed that the application of chitosan coating effectively maintained microbiological quality and extended shelf life of minimally processed broccoli. According to these results, the use of the edible chitosan coating alone or in combination with a heat mild shock appear to be a viable alternative for controlling microbiological growth and sensory attributes in minimally processed broccoli. The continuous consumer interest in high quality and food safety, combined with environmental concern has induced to the development and study of edible coatings that avoid the use of synthetic materials. The edible coatings, formed from generally recognized as safe materials, have the potential to reduce weight loss, respiration rate, and

  20. Gross motor coordination in junior tennis players.

    Science.gov (United States)

    Söğüt, Mustafa

    2016-11-01

    The purpose of this study was twofold: (1) to determine the gross motor coordination performance levels of junior tennis players and (2) to analyse the effects of age and gender. Participants were junior male (n = 50) and female (n = 51) tennis players aged 6-14. Körperkoordinationstest für Kinder (KTK) was used to assess the gross motor coordination of the participants. Results revealed that none of the participants performed lower than normal level in motor coordination. Besides, 40.6% of the participants performed above normal level. No gender differences were found on all subtests of KTK and also on total motor quotient. Although older players performed better on each test than their younger counterparts for the raw scores, no significant age effect was observed on motor quotient scores among different age groups.

  1. Chemical studies on the influence of a combined process of heat and irradiation on carbohydrates, proteins and amino acids of dates

    International Nuclear Information System (INIS)

    Auda, H.; Nasser, L.K.

    1981-01-01

    Chemical studies were conducted on the combined effects of heat and radiation on dates. The major sugars of dates were identified using gas chromatography. Total reducing carbohydrates were determined colorometrically. In general the stability of carbohydrates was observed throughout the experimental conditions where 40 0 C and 0.5 to 1 kGy were applied. Five sugars were detected by gas chromatography in both the control and the treated samples. The major three were identified to be fructose, glucose and sucrose with retention times of 2.3, 3.3 and 5.5 min, respectively. The influence of the combination treatments on protein and amino acids was also studied. The results show that proteins in dates are stable even at a 1-kGy dose and at 40 0 C. However, individual amino acids varied in their sensitivity to heat and this variation depended entirely on the individual amino acids. (author)

  2. Inhibitory effects of UV treatment and a combination of UV and dry heat against pathogens on stainless steel and polypropylene surfaces.

    Science.gov (United States)

    Bae, Young-Min; Lee, Sun-Young

    2012-01-01

    Pathogens that contaminate the surfaces of food utensils may contribute to the occurrence of foodborne disease outbreaks. We investigated the efficacy of UV treatment combined with dry heat (50 °C) for inhibiting 5 foodborne pathogens (Escherichia coli O157:H7, Salmonella Typhimurium, Pseudomonas aeruginosa, Listeria monocytogenes, and Staphylococcus aureus) on stainless steel and polypropylene surfaces in this study. We inoculated substrates with each of the 5 foodborne pathogens cultured on agar surface and then UV treatment alone or a combination of both UV and dry heat (50 °C) was applied for 30 min, 1 h, 2 h, and 3 h. The initial populations of the 5 pathogens before treatment were 8.02 to 9.18 and 8.73 to 9.16 log₁₀ CFU/coupon on the surfaces of stainless steel and polypropylene coupons, respectively. UV treatments for 3 h significantly inhibited S. Typhimurium, L. monocytogenes, and S. aureus on the stainless steel by 3.06, 2.18, and 2.70 log₁₀ CFU/coupon, and S. aureus on the polypropylene by 3.11 log₁₀ CFU/coupon, respectively. The inhibitory effects of the combined UV and dry heat treatment (50 °C) increased as treatment time increased, yielding significant reductions in all samples treated for 3 h, with the exception of S. aureus on polypropylene. The reduction level of E. coli O157:H7 treated for 3 h on the surface of stainless steel and polypropylene treated was approximately 6.00 log₁₀ CFU/coupon. These results indicate that combined UV and dry heat (50 °C) treatments may be effective for controlling microbial contamination on utensils and cooking equipment surfaces as well as in other related environments. © 2011 Institute of Food Technologists®

  3. Quantifying the effect of sorbic acid, heat and combination of both on germination and outgrowth of Bacillus subtilis spores at single cell resolution.

    Science.gov (United States)

    Pandey, Rachna; Pieper, Gerard H; Ter Beek, Alexander; Vischer, Norbert O E; Smelt, Jan P P M; Manders, Erik M M; Brul, Stanley

    2015-12-01

    Bacillus subtilis spores are a problem for the food industry as they are able to survive preservation processes. The spores often reside in food products, where their inherent protection against various stress treatments causes food spoilage. Sorbic acid is widely used as a weak acid preservative in the food industry. Its effect on spore germination and outgrowth in a combined, 'hurdle', preservation setting has gained limited attention. Therefore, the effects of mild sorbic acid (3 mM), heat-treatment (85 °C for 10 min) and a combination of both mild stresses on germination and outgrowth of B. subtilis 1A700 spores were analysed at single spore level. The heat-treatment of the spore population resulted in a germination efficiency of 46.8% and an outgrowth efficiency of 32.9%. In the presence of sorbic acid (3 mM), the germination and outgrowth efficiency was 93.3% and 80.4% respectively whereas the combined heat and sorbic acid stress led to germination and outgrowth efficiencies of 52.7% and 27.0% respectively. The heat treatment clearly primarily affected the germination process, while sorbic acid affected the outgrowth and generation time. In addition a new 'burst' time-point was defined as the time-point at which the spore coat visibly breaks and/or is shed. The combined stresses had a synergistic effect on the time of the end of germination to the burst time-point, increasing both the mean and its variation more than either of the single stresses did. Copyright © 2015 Elsevier Ltd. All rights reserved.

  4. Fabrication of TiO2 Crystalline Coatings by Combining Ti-6Al-4V Anodic Oxidation and Heat Treatments

    Directory of Open Access Journals (Sweden)

    María Laura Vera

    2015-01-01

    Full Text Available The bio- and hemocompatibility of titanium alloys are due to the formation of a TiO2 layer. This natural oxide may have fissures which are detrimental to its properties. Anodic oxidation is used to obtain thicker films. By means of this technique, at low voltages oxidation, amorphous and low roughness coatings are obtained, while, above a certain voltage, crystalline and porous coatings are obtained. According to the literature, the crystalline phases of TiO2, anatase, and rutile would present greater biocompatibility than the amorphous phase. On the other hand, for hemocompatible applications, smooth and homogeneous surfaces are required. One way to obtain crystalline and homogeneous coatings is by heat treatments after anodic oxidation. The aim of this study is to evaluate the influence of heat treatments on the thickness, morphology, and crystalline structure of the TiO2 anodic coatings. The characterization was performed by optical and scanning electron microscopy, X-ray diffraction, and X-ray reflectometry. Coatings with different colors of interference were obtained. There were no significant changes in the surface morphology and roughness after heat treatment of 500°C. Heat treated coatings have different proportions of the crystalline phases, depending on the voltage of anodic oxidation and the temperature of the heat treatment.

  5. Conjugate Heat Transfer Study at Interior Surface of NGV Leading Edge with Combined Shower Head and Impingement Cooling

    Directory of Open Access Journals (Sweden)

    Arun Kumar Pujari

    2014-01-01

    Full Text Available A computational study on conjugate heat transfer is carried out to present the behavior of nondimensional temperature and heat transfer coefficient of a Nozzle Guide Vane (NGV leading edge. Reynolds number of both mainstream flow and coolant impinging jets are varied. The NGV has five rows of film cooling holes arranged in shower head manner and four rows of impingement holes arranged in staggered manner. The results are presented by considering materials of different thermal conductivity. The results show that the mainstream flow affects the temperature distribution on the interior side of the vane leading edge for high conductivity material whereas it has negligible effects for low conductivity material. The effect of changing blowing ratio on internal heat transfer coefficient and internal surface temperature is also presented.

  6. Combined effect of thermal dispersion and variable viscosity of non-darcy convection heat transfer in a fluidsaturated porous medium

    KAUST Repository

    El-Amin, Mohamed

    2013-01-01

    In this paper, the effects of thermal dispersion and variable viscosity on the non-Darcy free, mixed, and forced convection heat transfer along a vertical flat plate embedded in a fluid-saturated porous medium are investigated. Forchheimer extension is employed in the flow equation to express the non-Darcy model. The fluid viscosity varies as an inverse linear function of temperature. The coefficient of thermal diffusivity has been assumed to be the sum of the molecular diffusivity and the dynamic diffusivity due to mechanical dispersion. Similarity solutions of the governing equations, for an isothermally heated plate, are obtained. Effects of the physical parameters, which govern the problem, on the rate of heat transfer in terms of Nusselt number, the slip velocity, and the boundary layer thickness, for the two cases Darcy and non-Darcy, are shown on graphs or entered in tables. © 2013 by Begell House, Inc.

  7. A dilution refrigerator combining low base temperature, high cooling power and low heat leak for use with nuclear cooling

    International Nuclear Information System (INIS)

    Bradley, D.I.; Guenault, A.M.; Keith, V.; Miller, I.E.; Pickett, G.R.; Bradshaw, T.W.; Locke-Scobie, B.G.

    1982-01-01

    The design philosophy, design, construction and performance of a dilution refrigerator specifically intended for nuclear cooling experiments in the submillikelvin regime is described. Attention has been paid from the outset to minimizing sources of heat leaks, and to achieving a low base temperature and relatively high cooling power below 10 mK. The refrigerator uses sintered silver heat exchangers similar to those developed at Grenoble. The machine has a base temperature of 3 mK or lower and can precool a copper nuclear specimen in 6.8 T to 8 mK in 70 h. The heat leak to the innermost nuclear stage is < 30 pW after only a few days' running. (author)

  8. Numerical simulations on conformable laser-induced interstitial thermotherapy through combined use of multi-beam heating and biodegradable nanoparticles.

    Science.gov (United States)

    Zhang, Jie; Jin, Chao; He, Zhi-Zhu; Liu, Jing

    2014-07-01

    Clinically, precisely heating and thus completely ablating diseased tumor tissue through laser beam is still facing many technical challenges. In this study, numerical simulation of a conformal heating modality based on multi-beam laser along with biodegradable magnesium nanoparticles (Mg-NPs) was put forward to treat liver tumor with large size or irregular shape. Further, a Gaussian-like distribution was proposed to investigate the influence of Mg-NP deposition on the nanoenhanced laser-induced interstitial thermotherapy (LITT). A temperature feedback system was adopted to control the temperature range to avoid overheating. To preliminarily validate the heating enhancement induced by the applied multi-beam laser and Mg-NPs, a conceptual experiment was performed. Both theoretical simulation and experimental measurements demonstrated that multi-beam laser with Mg-NPs could improve efficiency in the conformal heating of tumors with irregular shape or large size. In addition, the distribution and content of Mg-NPs produced significant impact on thermotherapy: (1) The adjustable parameter σ in the Gaussian-like distribution could reflect various practical situations and diffusivities of Mg-NPs; (2) under the premise of the same concentration of Mg-NPs and short time to heat a small-sized target, the whole liver tumor containing Mg-NPs could not improve the efficiency as the nanoparticles limited the photons to be absorbed only around the fibers, while liver tumor partially containing Mg-NPs could improve the thermotherapy efficiency up to 20 %; and (3) the addition of Mg-NPs was rather beneficial for realizing a conformal heating as the residual thermal energy was much less than that without Mg-NPs. This study suggests a feasible and promising modality for planning a high-performance LITT in future clinics.

  9. Less electricity. Methodology for obtaining lower electricity consumption in pumps and fans in heat and combined heat and power plants; Mindre El. Metodik foer minskad elfoerbrukning hos pumpar och flaektar i vaerme- och kraftvaermeanlaeggningar

    Energy Technology Data Exchange (ETDEWEB)

    Baafaelt, Martin; Ericsson, Roy; Schultz, Emma; Jeppesen, Jessica (Grontmij AB (SE))

    2007-12-15

    In many combined heat and power plants, auxiliary power has become an increasing economical concern due to rising prices on electricity. In a heating plant or a combined heat and power plant you easily overlook the use of auxiliary power as the plant itself has a much larger turnover of energy being delivered to its customers. Non-the less there are strong economical motives to investigate a plants internal usage of power. The largest users of power in a heat- or power plant are without doubt pumps and fans, which approximately accounts for 80-90 % of the total power consumption. Many measures to lessen the power usage in these components have been known for a long time, but have not been of interest in times when price on electricity is low and the difference in price between power and heat has been slight. The aim of this project is to create a tool for systematic analysis of pumps and fans in heat- and power plants. This tool is to add on to the Weighted Sum Method, WSM, presented in the report Mer El (VARMEFORSK--985). The tool works as an aid in making an inventory of and identifying the components with the largest potential of reducing their usage of energy. It can also illustrate the technical and economical effect these actions will result in. Target groups are owners of heat- and power plants and plant operators. Aided by WSM, the criteria technique, economy, organization and environment have a weight between 1 and 3 according to their importance. Thereafter every identified action is studied and scored in accordance with predetermined scales within each criterion. The weight and score are then multiplied, giving each action a rated efficiency in accordance to its advisability. The development, adjustment and verification of the method has been carried out at the plant Aaterbruket i Lomma, a plant within the company Lunds Energi. The verification of the method within the plant showed that only a few actions would be profitable to carry out. Therefore

  10. Psychiatric symptoms in children with gross motor problems

    NARCIS (Netherlands)

    Emck, C.; Bosscher, R.J.; van Wieringen, P.C.W.; Doreleijers, T.A.H.; Beek, P.J.

    2012-01-01

    dren with psychiatric disorders often demonstrate gross motor problems. This study investigates if the reverse also holds true by assessing psychiatric symptoms present in children with gross motor problems. Emotional, behavioral, and autism spectrum disorders (ASD), as well as psychosocial

  11. A Method Validation for Determination of Gross Alpha and Gross Beta in Water Sample Using Low Background Gross Alpha/ Beta Counting System

    International Nuclear Information System (INIS)

    Zal Uyun Wan Mahmood; Norfaizal Mohamed; Nita Salina Abu Bakar

    2016-01-01

    Method validation (MV) for the measurement of gross alpha and gross beta activity in water (drinking, mineral and environmental) samples using Low Background Gross Alpha/ Beta Counting System was performed to characterize precision, accuracy and reliable results. The main objective of this assignment is to ensure that both the instrument and method always good performed and resulting accuracy and reliable results. Generally, almost the results of estimated RSD, z-score and U score were reliable which are recorded as ≤30 %, less than 2 and less than 1.5, respectively. Minimum Detected Activity (MDA) was estimated based on the counting time of 100 minutes and present background counting value of gross alpha (0.01 - 0.35 cpm) and gross beta (0.50 - 2.18 cpm). Estimated Detection Limit (DL) was 0.1 Bq/ L for gross alpha and 0.2 Bq/ L for gross beta and expended uncertainty was relatively small of 9.77 % for gross alpha and 10.57 % for gross beta. Align with that, background counting for gross alpha and gross beta was ranged of 0.01 - 0.35 cpm and 0.50 - 2.18 cpm, respectively. While, sample volume was set at minimum of 500 mL and maximum of 2000 mL. These proven the accuracy and precision result that are generated from developed method/ technique is satisfactory and method is recommended to be used. Therefore, it can be concluded that the MV found no doubtful on the ability of the developed method. The test result showed the method is suitable for all types of water samples which are contained several radionuclides and elements as well as any impurities that interfere the measurement analysis of gross alpha and gross beta. (author)

  12. Combined quantum-mechanical and Calphad approach to description of heat capacity of pure elements below room temperature

    Czech Academy of Sciences Publication Activity Database

    Pavlů, J.; Řehák, Petr; Vřešťál, Jan; Šob, Mojmír

    2015-01-01

    Roč. 51, č. 1 (2015), s. 161-171 ISSN 0364-5916 Institutional support: RVO:68081723 Keywords : Einstein temperature * Heat capacity * Low temperature * Pure elements * SGTE data * Zero Kelvin Subject RIV: BM - Solid Matter Physics ; Magnetism Impact factor: 2.129, year: 2015

  13. Modification of cassava starch using combination process lactic acid hydrolysis and micro wave heating to increase coated peanut expansion quality

    Science.gov (United States)

    Sumardiono, Siswo; Pudjihastuti, Isti; Jos, Bakti; Taufani, Muhammad; Yahya, Faad

    2017-05-01

    Modified cassava starch is very prospective products in the food industry. The main consideration of this study is the increasing volume of imported wheat and the demand for modified cassava starch industry. The purpose of this study is the assessing of lactic acid hydrolysis and microwave heating impact to the physicochemical and rheological properties of modified cassava starch, and test applications of modified cassava starch to coated peanut expansion quality. Experimental variables include the concentration of lactic acid (0.5% w/w, 1% w/w; 2% w/w), a time of hydrolysis (15, 30, 45 minutes), a time of microwave heating (1, 2, 3 hours). The research step is by dissolving lactic acid using aquadest in the stirred tank reactor, then added cassava starch. Hydrolysed cassava starch was then heated by microwave. Physicochemical properties and rheology of the modified cassava starch is determined by the solubility, swelling power, and test congestion. The optimum obtained results indicate that solubility, swelling power, congestion test, respectively for 19.75%; 24.25% and 826.10% in the hydrolysis treatment for 15 minutes, 1% w lactic acid and microwave heating 3 hours. The physicochemical and rheological properties of modified cassava starch have changed significantly when compared to the native cassava starch. Furthermore, these modified cassava starch are expected to be used for the substitution of food products.

  14. Combined particle emission reduction and heat recovery from combustion exhaust-A novel approach for small wood-fired appliances

    International Nuclear Information System (INIS)

    Messerer, A.; Schmatloch, V.; Poeschl, U.; Niessner, R.

    2007-01-01

    Replacing fossil fuels by renewable sources of energy is one approach to address the problem of global warming due to anthropogenic emissions of greenhouse gases. Wood combustion can help to replace fuel oil or gas. It is advisable, however, to use modern technology for combustion and exhaust gas after-treatment in order to achieve best efficiency and avoid air quality problems due to high emission levels often related to small scale wood combustion. In this study, simultaneous combustion particle deposition and heat recovery from the exhaust of two commercially available wood-fired appliances has been investigated. The experiments were performed with a miniature pipe bundle heat exchanger operating in the exhaust gas lines of a fully automated pellet burner or a closed fireplace. The system has been characterised for a wide range of aerosol inlet temperatures (135-295 deg. C) and flow velocities (0.13-1.0ms -1 ), and particle deposition efficiencies up to 95% have been achieved. Deposition was dominated by thermophoresis and diffusion and increased with the average temperature difference and retention time in the heat exchanger. The aerosols from the two different appliances exhibited different deposition characteristics, which can be attributed to enhanced deposition of the nucleation mode particles generated in the closed fire place. The measured deposition efficiencies can be described by simple linear parameterisations derived from laboratory studies. The results of this study demonstrate the feasibility of thermophoretic particle removal from biomass burning flue gas and support the development of modified heat exchanger systems with enhanced capability for simultaneous heat recovery and particle deposition

  15. Combining coal gasification, natural gas reforming, and external carbonless heat for efficient production of gasoline and diesel with CO2 capture and sequestration

    International Nuclear Information System (INIS)

    Salkuyeh, Yaser Khojasteh; Adams, Thomas A.

    2013-01-01

    Highlights: • Several systems are presented which convert NG, coal, and carbonless heat to fuel. • Using nuclear heat can reduce the direct fossil fuel consumption by up to 22%. • The use of CCS depended on the carbon tax: above $20-30/t is sufficient to use CCS. • CTL is only the most economical when the price of NG is more than $5 /MMBtu. • Compared to a traditional CTL plant, total CO 2 emission can be reduced up to 79%. - Abstract: In this paper, several novel polygeneration systems are presented which convert natural gas, coal, and a carbonless heat source such as high-temperature helium to gasoline and diesel. The carbonless heat source drives a natural gas reforming reaction to produce hydrogen rich syngas, which is mixed with coal-derived syngas to produce a syngas blend ideal for the Fischer–Tropsch reaction. Simulations and techno-economic analyses performed for 16 different process configurations under a variety of market conditions indicate significant economic and environmental benefits. Using a combination of coal, gas, and carbonless heat, it is possible to reduce CO 2 emissions (both direct and indirect) by 79% compared to a traditional coal-to-liquids process, and even achieve nearly zero CO 2 emissions when carbon capture and sequestration technology is employed. Using a carbonless heat source, the direct fossil fuel consumption can be reduced up to 22% and achieve a carbon efficiency up to 72%. Market considerations for this analysis include prices of coal, gas, high-temperature helium, gasoline, and CO 2 emission tax rates. The results indicate that coal-only systems are never the most economical choice, unless natural gas is more than 5 $/MMBtu

  16. An evaluation of a farm scale biogas plant with a micro turbine for combined heat and power production; Utvaerdering av gaardsbiogasanlaeggning med mikroturbin foer kraftvaermeproduktion

    Energy Technology Data Exchange (ETDEWEB)

    Brown, Nils; Edstroem, Mats; Hansson, Mikael (Swedish Inst. of Agricultural and Environmental Engineering, Uppsala (Sweden)); Algerbo, Per-Anders (HIR Malmoehus, Bjaerred (Sweden))

    2010-03-15

    The purpose of this study was to: To evaluate a farm scale biogas plant digesting energy and nutrient rich substrates at a high organic loading rate and biogas production using the biogas for combined heat and power production with a micro turbine. Put together technical, biological and economical documentation which can help farmers to investigate presumption to invest in a farm scale biogas plant for heat and power production. The farm scale biogas plant has an active digester volume of 450 m3 and the process temperature is ca 37 deg C. A micro turbine with 105 kW electrical and 160 kW thermal power is used for heat and power production. The produced electricity is sold to the grid and the heat is used on the farm for drying grain and heating two houses. The plant is digesting poultry manure and 2 substrates from the agriculture industry. All together the plant is digesting 3140 metric tons of substrates/yr and the substrates costs 160 k SEK/yr. Total investment for the plant is 4.7 M SEK. Produced head reduces the oil consumption at the farm with 15 m3 (value 100 k SEK/yr). There is a surplus of heat production of 600 MWh/yr. The production cost for the electricity is close to 0,66 SEK/kWh based on a value of the digestate of 100 SEK/ton together with an investment subsidy of 30 %. The production cost for the electricity is strongly depending on the value of the digestate. Hagavik is a crop production farm based on organic farming. If the valuation of the digestate is reduced to 50 SEK/ton, the production cost for the electricity increases to approx. 0.84 SEK/kWh (1 SEK is about 0.14 USD)

  17. Combined convective heat and airborne pollutant removals in a slot vented enclosure under different flow schemes: Parametric investigations and non unique flow solutions

    International Nuclear Information System (INIS)

    Ren, Xiu-Hong; Hu, Jiang-Tao; Liu, Di; Zhao, Fu-Yun; Li, Xiao-Hong; Wang, Han-Qing

    2016-01-01

    Highlights: • Combined convective heat and airborne transports under different flow schemes. • Natural and forced convection dominated regimes were identified with transition. • Dual solution branches were sustained for the transitional mixing flow scheme. • Rest solutions evolving from motionless flows coincided with other solution branch. • Heat and species lines were presented to delineate heat and mass transport structures. - Abstract: This paper reports a numerical study of mixed convection on a heated and polluted strip within a slot ventilated enclosure in which the displacement and mixing flow schemes are considered. Contours of streamfunction, heatfunction, and massfunction are presented to clearly scrutinize the mechanism of heat and airborne pollutant transports. For the displacement flow scheme, thermal Nusselt and pollutant Sherwood numbers under different Reynolds numbers remain almost constant as the value of Gr/Re 2 decreases down to the regime of forced convection dominated. However, as Ar increases up to the regime of natural convection dominated, both Nu and Sh increase sharply with Ar (Gr/Re 2 ). Similar trends could be observed for the situation of mixing ventilated flow scheme. In the mixing scheme, non unique steady flow solutions could be observed for the range of transitional flow regime. Upward solutions, downward solutions and rest solutions have been exemplified with varying Gr/Re 2 . Dual solution branches could be sustained at the range of 39.0 ≤ Gr/Re 2  ≤ 6.0 × 10 3 , while the rest solutions obtained from rest states were completely coinciding with former continuous solutions. The present work could be significant for the natural optimization and passive control of heat and pollutant removals from the electronic boxes or building enclosures.

  18. Latin and Greek in gross anatomy.

    Science.gov (United States)

    Smith, Sean B; Carmichael, Stephen W; Pawlina, Wojciech; Spinner, Robert J

    2007-04-01

    Medical students and practitioners learn and use a vocabulary originating almost entirely from classical Latin and Greek languages. Previous generations required Latin or Greek prior to medical school, but the current generation does not have such requirements. Anecdotal evidence suggests that understanding Latin or Greek helps students to learn and practitioners to recall otherwise foreign terminology. This study evaluated students' familiarity with Latin and Greek etymologies before and after a gross anatomy course that incorporated etymologies into its curriculum. First-year medical students at Mayo Clinic College of Medicine were taught Latin and Greek etymologies through lectures and handouts during their gross anatomy course. They took a pretest and a posttest before and after the course to assess their understanding of etymologies. In addition, students from all four years of medical school, residents, and staff physicians also took a general etymology quiz to assess their understanding of etymologies. After their gross anatomy course emphasizing etymologies, first-year students scored higher on the posttest than they did on the pretest. First-year students also reported that learning etymologies enhanced anatomy learning, made the experience more enjoyable, and proved to be less difficult than they thought it would be prior to the course. Medical students, residents, and staff physicians scored almost equally on the general etymology quiz and almost equally reported that etymologies enhanced learning and recalling terminology. Medical students, residents, and staff physicians almost equally endorsed incorporating etymologies into medical education. This study provides novel scientific evidence that a basic understanding of Latin and Greek etymologies enhances performance and comfort when learning and using medical terminology.

  19. Innovative procedure for the determination of gross-alpha/gross-beta activities in drinking water