  1. Grip Strength Survey Based on Hand Tool Usage

    Directory of Open Access Journals (Sweden)

    Erman ÇAKIT

    2016-12-01

    Full Text Available Hand grip strength is broadly used for performing tasks involving equipment in production and processing activities. Most professionals in this field rely on grip strength to perform their tasks. There were three main aims of this study: i determining various hand grip strength measurements for the group of hand tool users, ii investigating the effects of height, weight, age, hand dominance, body mass index, previous Cumulative Trauma Disorder (CTD diagnosis, and hand tool usage experience on hand grip strength, and iii comparing the obtained results with existing data for other populations. The study groups comprised 71 healthy male facility workers. The values of subjects’ ages was observed between 26 and 74 years. The data were statistically analyzed to assess the normality of data and the percentile values of grip strength. The results of this study demonstrate that there were no significance differences noted between dominant and non-dominant hands. However, there were highly significant differences between the CTD group and the other group. Hand grip strength for the dominant hand was positively correlated to height, weight, and body mass index, and negatively correlated to age and tool usage experience. Hand dominance, height, weight, body mass index, age and tool usage experience should be considered when establishing normal values for grip strength.

  2. Thimble grip fuel assembly handling tool

    International Nuclear Information System (INIS)

    Salton, R.B.; Hornak, L.P.; Marshall, J.R.; Meuschke, R.E.

    1989-01-01

    This patent describes an apparatus for lifting a fuel assembly of a nuclear reactor. The fuel assembly consists of a top nozzle and control rod guide tubes. The apparatus having a gripping means comprised of: a life plate, an actuating plate having a plurality of apertures, the actuating plate disposed in spaced relationship below the lift plate and vertically movable relative thereto; gripping members operably associated with the lift and actuating plates, the gripping members comprising: (a) a vertical rod fixedly secured near its top end to the lift plate and projecting downward therefrom through an associated aperture in the actuating plate, the rod having a first frustoconical surface formed near its lower end, (b) a generally cylindrical, elastically deformable vertical sleeve having a bore therethrough with a first inner diameter, the sleeve having a first bevelled inside surface near the top end and a second bevelled inside surface at the bottom end of the sleeve, and (c) a vertical gripper actuator disposed about the rod

  3. NBL Pistol Grip Tool for Underwater Training of Astronauts

    Science.gov (United States)

    Liszka, Michael; Ashmore, Matthew; Behnke, Mark; Smith, Walter; Waterman, Tod

    2011-01-01

    A document discusses a lightweight, functional mockup of the Pistol Grip Tool for use during underwater astronaut training. Previous training tools have caused shoulder injuries. This new version is more than 50 percent lighter [in water, weight is 2.4 lb (=1.1 kg)], and can operate for a six-hour training session after 30 minutes of prep for submersion. Innovations in the design include the use of lightweight materials (aluminum and Delrin(Registered TradeMark)), creating a thinner housing, and the optimization of internal space with the removal of as much excess material as possible. This reduces tool weight and maximizes buoyancy. Another innovation for this tool is the application of a vacuum that seats the Orings in place and has shown to be reliable in allowing underwater usage for up to six hours.

  4. Progress on the interface between UPP and CPRHS (Cask and Plug Remote Handling System) tractor/gripping tool for ITER

    International Nuclear Information System (INIS)

    Rosa, Elena V.; Rios, Luis; Queral, Vicente

    2013-01-01

    Highlights: ► UPP interface requirements in the plug RH extraction/insertion for ITER. ► Analyze of maximum misalignment between port duct and port cell. ► Friction study between plug skids and VV port/ramp rails during the plug transfer. ► Definition of the tolerance in the plug skids to avoid the plug jamming. ► Concepts of gripping tools based on one gripping point and avoiding force feedback. -- Abstract: EFDA finances a training programme called Goal Oriented Training Programme for Remote Handling (GOT RH), whose goal is to train engineers in Remote Handling for ITER. As part of this training programme, the conceptual design of the mechanical interface between Upper Port Plug (UPP) and Cask and Plug Remote Handling System (CPRHS) as well as the conceptual design of the needed tools for UPP Remote Handling is carried out. The paper presents the conceptual design of the UPP/Gripping Tool Interface. This includes the conceptual design of the gripping tool for introducing/removing the UPP in/from the ITER port and the mechanical features on both sides of the UPP/Gripping Tool Interface (e.g. alignment features, mechanical connectors, fasteners). In order to develop the design of the interface between UPP and CPRHS it is necessary to first identify the functional requirements of the Transfer Cask System (TCS) and the CPRHS, such as required degrees of freedom (DoF), required performances of system, geometrical constraints, loading conditions, alignment requirements, RAMI requirements. These requirements are the input data for the design of the interface between UPP and gripping tool and some of them are also described in the paper

  5. To grip or not to grip: An experimental approach for understanding the use of prehensile areas in mousterian tools

    OpenAIRE

    Baena Preysler, Javier; Torres Navas, Concepción; Pérez Díaz, Sara; Bustos-Pérez, Guillermo; Romagnoli, Francesca

    2016-01-01

    The existence of a more or less complex handling technology with the lithic tools during the Lower and Middle Paleolithic is an interesting topic for understanding aspects of the human behavior during these periods. In this work we present a preliminary experimental evaluation of the possible functionality of prehensile area in some of the most representative lithic types of the Mousterian assemblages (dorsal elements and levallois chapeau de gendarme proximal area), in which t...

  6. PGT: A Statistical Approach to Prediction and Mechanism Design

    Science.gov (United States)

    Wolpert, David H.; Bono, James W.

    One of the biggest challenges facing behavioral economics is the lack of a single theoretical framework that is capable of directly utilizing all types of behavioral data. One of the biggest challenges of game theory is the lack of a framework for making predictions and designing markets in a manner that is consistent with the axioms of decision theory. An approach in which solution concepts are distribution-valued rather than set-valued (i.e. equilibrium theory) has both capabilities. We call this approach Predictive Game Theory (or PGT). This paper outlines a general Bayesian approach to PGT. It also presents one simple example to illustrate the way in which this approach differs from equilibrium approaches in both prediction and mechanism design settings.

  7. Therapeutic Efficacy of Vectored PGT121 Gene Delivery in HIV-1-Infected Humanized Mice.

    Science.gov (United States)

    Badamchi-Zadeh, Alexander; Tartaglia, Lawrence J; Abbink, Peter; Bricault, Christine A; Liu, Po-Ting; Boyd, Michael; Kirilova, Marinela; Mercado, Noe B; Nanayakkara, Ovini S; Vrbanac, Vladimir D; Tager, Andrew M; Larocca, Rafael A; Seaman, Michael S; Barouch, Dan H

    2018-04-01

    Broadly neutralizing antibodies (bNAbs) are being explored for HIV-1 prevention and cure strategies. However, administration of purified bNAbs poses challenges in resource-poor settings, where the HIV-1 disease burden is greatest. In vivo vector-based production of bNAbs represents an alternative strategy. We investigated adenovirus serotype 5 (Ad5) and adeno-associated virus serotype 1 (AAV1) vectors to deliver the HIV-1-specific bNAb PGT121 in wild-type and immunocompromised C57BL/6 mice as well as in HIV-1-infected bone marrow-liver-thymus (BLT) humanized mice. Ad5.PGT121 and AAV1.PGT121 produced functional antibody in vivo Ad5.PGT121 produced PGT121 rapidly within 6 h, whereas AAV1.PGT121 produced detectable PGT121 in serum by 72 h. Serum PGT121 levels were rapidly reduced by the generation of anti-PGT121 antibodies in immunocompetent mice but were durably maintained in immunocompromised mice. In HIV-1-infected BLT humanized mice, Ad5.PGT121 resulted in a greater reduction of viral loads than did AAV1.PGT121. Ad5.PGT121 also led to more-sustained virologic control than purified PGT121 IgG. Ad5.PGT121 afforded more rapid, robust, and durable antiviral efficacy than AAV1.PGT121 and purified PGT121 IgG in HIV-1-infected humanized mice. Further evaluation of vector delivery of HIV-1 bNAbs is warranted, although approaches to prevent the generation of antiantibody responses may also be required. IMPORTANCE Broadly neutralizing antibodies (bNAbs) are being explored for HIV-1 prevention and cure strategies, but delivery of purified antibodies may prove challenging. We investigated adenovirus serotype 5 (Ad5) and adeno-associated virus serotype 1 (AAV1) vectors to deliver the HIV-1-specific bNAb PGT121. Ad5.PGT121 afforded more rapid, robust, and durable antiviral efficacy than AAV1.PGT121 and purified PGT121 IgG in HIV-1-infected humanized mice. Copyright © 2018 Badamchi-Zadeh et al.

  8. Biomimetics approach for methods to release microobjects from the gripping tool

    DEFF Research Database (Denmark)

    Gegeckaite, Asta; Moon, Jack; Hansen, Hans Nørgaard

    2005-01-01

    of handling can be found in for example insect everyday life, cells, enzymes etc. To find out these principles we need special tools, like BioDlab database, which is created specially to find the examples form the biology in order to solve engineering problems. In this report different principles of handling...... at the micro and nano level are presented as well as solutions for micro assembly principles are introduced, concentrating on the adhesion and releasing during the picking and releasing stages of the handling scenario....

  9. Effects of hyperthyroidism on hand grip strength and function.

    Science.gov (United States)

    Erkol İnal, Esra; Çarlı, Alparslan Bayram; Çanak, Sultan; Aksu, Oğuzhan; Köroğlu, Banu Kale; Savaş, Serpil

    2015-01-01

    Hyperthyroidism is a pathologic condition in which the body is exposed to excessive amounts of circulating thyroid hormones. Skeletal muscle is one of the major target organs of thyroid hormones. We evaluated hand grip strength and function in patients with overt hyperthyroidism. Fifty-one patients newly diagnosed with hyperthyroidism and 44 healthy controls participated in this study. Age, height, weight, and dominant hand of all participants were recorded. The diagnosis of hyperthyroidism was confirmed by clinical examination and laboratory tests. Hand grip strength was tested at the dominant hand with a Jamar hand dynamometer. The grooved pegboard test (PGT) was used to evaluate hand dexterity. The Duruöz Hand Index (DHI) was used to assess hand function. No significant differences were found in terms of clinical and demographic findings between the patients with hyperthyroidism and healthy controls (p > 0.05). Significant differences were found between the patients with hyperthyroidism and healthy controls regarding PGT and DHI scores (p Hyperthyroidism seemed to affect hand dexterity and function more than hand grip strength and seemed to be associated with reduced physical function more than muscle strength. This may also indicate that patients with hyperthyroidism should be evaluated by multidisplinary modalities.

  10. Effects of glovebox gloves on grip and key pinch strength and contact forces for simulated manual operations with three commonly used hand tools.

    Science.gov (United States)

    Sung, Peng-Cheng

    2014-01-01

    This study examined the effects of glovebox gloves for 11 females on maximum grip and key pinch strength and on contact forces generated from simulated tasks of a roller, a pair of tweezers and a crescent wrench. The independent variables were gloves fabricated of butyl, CSM/hypalon and neoprene materials; two glove thicknesses; and layers of gloves worn including single, double and triple gloving. CSM/hypalon and butyl gloves produced greater grip strength than the neoprene gloves. CSM/hypalon gloves also lowered contact forces for roller and wrench tasks. Single gloving and thin gloves improved hand strength performances. However, triple layers lowered contact forces for all tasks. Based on the evaluating results, selection and design recommendations of gloves for three hand tools were provided to minimise the effects on hand strength and optimise protection of the palmar hand in glovebox environments. To improve safety and health in the glovebox environments where gloves usage is a necessity, this study provides recommendations for selection and design of glovebox gloves for three hand tools including a roller, a pair of tweezers and a crescent wrench based on the results discovered in the experiments.

  11. The effect of force feedback delay on stiffness perception and grip force modulation during tool-mediated interaction with elastic force fields.

    Science.gov (United States)

    Leib, Raz; Karniel, Amir; Nisky, Ilana

    2015-05-01

    During interaction with objects, we form an internal representation of their mechanical properties. This representation is used for perception and for guiding actions, such as in precision grip, where grip force is modulated with the predicted load forces. In this study, we explored the relationship between grip force adjustment and perception of stiffness during interaction with linear elastic force fields. In a forced-choice paradigm, participants probed pairs of virtual force fields while grasping a force sensor that was attached to a haptic device. For each pair, they were asked which field had higher level of stiffness. In half of the pairs, the force feedback of one of the fields was delayed. Participants underestimated the stiffness of the delayed field relatively to the nondelayed, but their grip force characteristics were similar in both conditions. We analyzed the magnitude of the grip force and the lag between the grip force and the load force in the exploratory probing movements within each trial. Right before answering which force field had higher level of stiffness, both magnitude and lag were similar between delayed and nondelayed force fields. These results suggest that an accurate internal representation of environment stiffness and time delay was used for adjusting the grip force. However, this representation did not help in eliminating the bias in stiffness perception. We argue that during performance of a perceptual task that is based on proprioceptive feedback, separate neural mechanisms are responsible for perception and action-related computations in the brain. Copyright © 2015 the American Physiological Society.

  12. Somatic populations of PGT135-137 HIV-1-neutralizing antibodies identified by 454 pyrosequencing and bioinformatics

    Directory of Open Access Journals (Sweden)

    Jiang eZhu

    2012-09-01

    Full Text Available Select HIV-1-infected individuals develop sera capable of neutralizing diverse viral strains. The molecular basis of this neutralization is currently being deciphered by the isolation of HIV-1-neutralizing antibodies. In one infected donor, three neutralizing antibodies, PGT135-137, were identified by assessment of neutralization from individually sorted B cells and found to recognize an epitope containing an N-linked glycan at residue 332 on HIV-1 gp120. Here we use deep sequencing and bioinformatics methods to interrogate the B cell record of this donor to gain a more complete understanding of the humoral immune response. PGT135-137-gene family-specific primers were used to amplify heavy and light chain-variable domain sequences. 454 pyrosequencing produced 141,298 heavy-chain sequences of IGHV4-39 origin and 87,229 light-chain sequences of IGKV3-15 origin. A number of heavy and light chain sequences of ~90% identity to PGT137, several to PGT136, and none of high identity to PGT135 were identified. After expansion of these sequences to include close phylogenetic relatives, a total of 202 heavy-chain sequences and 72 light-chain sequences were identified. These sequences were clustered into populations of 95% identity comprising 15 for heavy chain and 10 for light chain, and a select sequence from each population was synthesized and reconstituted with a PGT137-partner chain. Reconstituted antibodies showed varied neutralization phenotypes for HIV-1 clade A and D isolates. Sequence diversity of the antibody population represented by these tested sequences was notably higher than observed with a 454 pyrosequencing-control analysis on 10 antibodies of defined sequence, suggesting that this diversity results primarily from somatic maturation. Our results thus provide an example of how pathogens like HIV-1 are opposed by a varied humoral immune response, derived from intrinsic mechanisms of antibody development, and embodied by somatic populations

  13. Hand grip strength

    DEFF Research Database (Denmark)

    Frederiksen, Henrik; Gaist, David; Petersen, Hans Christian

    2002-01-01

    in life is a major problem in terms of prevalence, morbidity, functional limitations, and quality of life. It is therefore of interest to find a phenotype reflecting physical functioning which has a relatively high heritability and which can be measured in large samples. Hand grip strength is known......-55%). A powerful design to detect genes associated with a phenotype is obtained using the extreme discordant and concordant sib pairs, of whom 28 and 77 dizygotic twin pairs, respectively, were found in this study. Hence grip strength is a suitable phenotype for identifying genetic variants of importance to mid...

  14. GRIP CAMPAIGN REPORTS V1

    Data.gov (United States)

    National Aeronautics and Space Administration — The GRIP Campaign Reports dataset consists of various reports filed by scientists during the GRIP campaign which took place 8/15/2010 - 9/30/2010; however, several...

  15. Road grip test in Arjeplog

    OpenAIRE

    Engström, Niclas; Andrén, Henrik; Nybacka, Mikael; Fransson, Lennart; Larsson, Roland

    2008-01-01

    The Swedish road administration sees a need to improve the road grip estimation capacity for the Swedish road system. The challenge is to find methods to measure road grip fast and reliable. There where six different system types at the tests in Arjeplog, three continuous, two system measuring road grip through deceleration and one system based on GPS and accelerometers. Two system types used air craft runway tires. The other systems used either studded winter tires or friction winter tires. ...

  16. Enter the Gripping Beast

    DEFF Research Database (Denmark)

    Sindbæk, Søren Michael

    2012-01-01

    on innovations. Mostly, however, the time-resolution of archaeological data is too coarse-grained to allow us to grasp this potential to the full. In the period c. AD 790-850 a distinctly new artistic motif, the Gripping Beast, emerged in Scandinavia. A series of narrowly dated contexts provide anchor points......, which allows us to chart this innovation process and to point out some of the locations where this development took place; the reception of the mew motif is traced in grave finds across Scandinavia. This allows us to follow an early medieval innovation through the human-material interactions of an actor-network....

  17. The GRIP method for collaborative roadmapping workshops

    DEFF Research Database (Denmark)

    Piirainen, Kalle

    2015-01-01

    Technology roadmapping is a well-known tool for technology management, but practical advice for facilitating collaborative roadmapping workshops is relatively scarce. To cater for this need, we have designed a method for collaborative roadmapping, dubbed the GRIP method, for facilitating group work...... in TRM workshops. The design is based on establish best practices in facilitation and our experiences with the method suggest it is a feasible tool for technology managers. The benefits of the method are that it enables engaging a diverse group of individuals to the roadmapping process effectively even...... during a short workshop session and facilitates shared understanding on the technology management issues....

  18. Grip for sawing round timber

    Energy Technology Data Exchange (ETDEWEB)

    1982-07-01

    This paper describes a device development at Gedling Colliery, Nottinghamshire Area, United Kingdom. It is a gripping attachment, designed to overcome the safety hazards involved in cross cutting timbers with a circular saw.

  19. Gripped by movies: From story-world to artifact absorption

    NARCIS (Netherlands)

    Doicaru, M.M.

    2016-01-01

    That movies are a great source of entertainment seems to be common sense. But how exactly movies manage to get large audiences absorbed, or what is their gripping tool is still a mystery. Research makes use of different concepts pointing to narrative absorption, but it is not clear how they differ

  20. Improvement of handle grip using reverse engineering, CAE and Rapid Prototyping

    Directory of Open Access Journals (Sweden)

    Stoklasek Pavel

    2016-01-01

    Full Text Available The overwhelming majority of manual operations is even nowadays performed by using manual hand tools. These tools can be divided into 2 groups – hand tools designed for general use or a single-purpose hand tools for special operations. Tool described in this paper is used in assembling operation in the completion of electric motor. During the design of the existing tools the requirements for a functional part of the tool (lifespan, inability to damage the engine installation were fully considered, demands for ergonomic grip area, however, were not taken into account. Long-term use of incorrectly designed tool causes carpal tunnel syndrome, hand-arm vibration syndrome, diminished sensitivity or tingling in the fingers of workers. These difficulties can be reduced or entirely eliminated due to proper design of the grip of hand tool. Most authors focus on adjusting the grip for optimum ergonomics at individual types of grips (cylindrical, palmar, lateral, etc.. However, as already mentioned, there are tools for specific operations when the working area is limited by space or a specific type of load on the grip is needed. In some cases, it is often necessary to change the type of grip or combine different types of grips. This paper describes the design of an optimal grip of hand tool used for specific operation when assembling motors. Design of prototype mold and production of functional prototypes for ergonomics assessment directly in the workplace were realized. New design of handle should reduce the risk primarily of developing carpal tunnel in long-term use.

  1. Reference Values of Grip Strength, Prevalence of Low Grip Strength, and Factors Affecting Grip Strength Values in Chinese Adults.

    Science.gov (United States)

    Yu, Ruby; Ong, Sherlin; Cheung, Osbert; Leung, Jason; Woo, Jean

    2017-06-01

    The objectives of this study were to update the reference values of grip strength, to estimate the prevalence of low grip strength, and to examine the impact of different aspects of measurement protocol on grip strength values in Chinese adults. A cross-sectional survey of Chinese men (n = 714) and women (n = 4014) aged 18-102 years was undertaken in different community settings in Hong Kong. Grip strength was measured with a digital dynamometer (TKK 5401 Grip-D; Takei, Niigata, Japan). Low grip strength was defined as grip strength 2 standard deviations or more below the mean for young adults. The effects of measurement protocol on grip strength values were examined in a subsample of 45 men and women with repeated measures of grip strength taken with a hydraulic dynamometer (Baseline; Fabrication Enterprises Inc, Irvington, NY), using pair t-tests, intraclass correlation coefficient, and Bland and Altman plots. Grip strength was greater among men than among women (P values than the Baseline hydraulic dynamometer (P values were also observed when the measurement was performed with the elbow extended in a standing position, compared with that with the elbow flexed at 90° in a sitting position, using the same dynamometer (P values of grip strength and estimated the prevalence of low grip strength among Chinese adults spanning a wide age range. These findings might be useful for risk estimation and evaluation of interventions. However, grip strength measurements should be interpreted with caution, as grip strength values can be affected by type of dynamometer used, assessment posture, and elbow position. Copyright © 2017 AMDA – The Society for Post-Acute and Long-Term Care Medicine. Published by Elsevier Inc. All rights reserved.

  2. Why pens have rubbery grips

    Science.gov (United States)

    Dzidek, Brygida; Bochereau, Séréna; Johnson, Simon A.; Hayward, Vincent; Adams, Michael J.

    2017-10-01

    The process by which human fingers gives rise to stable contacts with smooth, hard objects is surprisingly slow. Using high-resolution imaging, we found that, when pressed against glass, the actual contact made by finger pad ridges evolved over time following a first-order kinetics relationship. This evolution was the result of a two-stage coalescence process of microscopic junctions made between the keratin of the stratum corneum of the skin and the glass surface. This process was driven by the secretion of moisture from the sweat glands, since increased hydration in stratum corneum causes it to become softer. Saturation was typically reached within 20 s of loading the contact, regardless of the initial moisture state of the finger and of the normal force applied. Hence, the gross contact area, frequently used as a benchmark quantity in grip and perceptual studies, is a poor reflection of the actual contact mechanics that take place between human fingers and smooth, impermeable surfaces. In contrast, the formation of a steady-state contact area is almost instantaneous if the counter surface is soft relative to keratin in a dry state. It is for this reason that elastomers are commonly used to coat grip surfaces.

  3. GRIP HURRICANE IMAGING RADIOMETER (HIRAD) V1

    Data.gov (United States)

    National Aeronautics and Space Administration — The GRIP Hurricane Imaging Radiometer (HIRAD) V1 dataset contains measurements of brightness temperature taken at 4, 5, 6 and 6.6 GHz, as well as MERRA 2 m wind...

  4. GRIP LIGHTNING INSTRUMENT PACKAGE (LIP) V1

    Data.gov (United States)

    National Aeronautics and Space Administration — The GRIP Lightning Instrument Package (LIP) dataset was collected by the Lightning Instrument Package (LIP), which consists of 6 rotating vane type electric field...

  5. GRIP FLIGHT TRACKS AND ANIMATIONS V1

    Data.gov (United States)

    National Aeronautics and Space Administration — The GRIP Flight Tracks and Animations dataset includes both KML files and animation files. The KML files use Google Earth to show the flight tracks on a map. The...

  6. Adjustment of gripping force by optical systems

    Science.gov (United States)

    Jalba, C. K.; Barz, C.

    2018-01-01

    With increasing automation, robotics also requires ever more intelligent solutions in the handling of various tasks. In this context, many grippers must also be re-designed. For this, they must always be adapted for different requirements. The equipment of the gripper systems with sensors should help to make the gripping process more intelligent. In order to achieve such objectives, optical systems can also be used. This work analyzes how the gripping force can be adjusted by means of an optical recognition. The result of this work is the creation of a connection between optical recognition, tolerances, gripping force and real-time control. In this way, algorithms can be created, with the aid of which robot grippers as well as other gripping systems become more intelligent.

  7. Reliability of the Bulb Dynamometer for Assessing Grip Strength

    Directory of Open Access Journals (Sweden)

    Colleen Maher

    2018-04-01

    Full Text Available Background: Hand function is an overall indicator of health and is often measured using grip strength. Handheld dynamometry is the most common method of measuring grip strength. The purpose of this study was to determine the inter-rater and test-retest reliability, the reliability of one trial versus three trials, and the preliminary norms for a young adult population using the Baseline® Pneumatic Squeeze Bulb Dynamometer (30 psi. Methods: This study used a one-group methodological design. One hundred and three healthy adults (30 males and 73 females were recruited. Six measurements were collected for each hand per participant. The data was analyzed using Intraclass Correlation Coefficients (ICC two-way effects model (2,2 and paired-samples t-tests. Results: The ICC for inter-rater reliability ranged from 0.955 to 0.977. Conclusion: The results of this study suggest that the bulb dynamometer is a reliable tool to measure grip strength and should be further explored for reliable and valid use in diverse populations and as an alternative to the Jamar dynamometer.

  8. The handyman's brain: a neuroimaging meta-analysis describing the similarities and differences between grip type and pattern in humans.

    Science.gov (United States)

    King, M; Rauch, H G; Stein, D J; Brooks, S J

    2014-11-15

    Handgrip is a ubiquitous human movement that was critical in our evolution. However, the differences in brain activity between grip type (i.e. power or precision) and pattern (i.e. dynamic or static) are not fully understood. In order to address this, we performed Activation Likelihood Estimation (ALE) analysis between grip type and grip pattern using functional magnetic resonance imaging (fMRI) data. ALE provides a probabilistic summary of the BOLD response in hundreds of subjects, which is often beyond the scope of a single fMRI experiment. We collected data from 28 functional magnetic resonance data sets, which included a total of 398 male and female subjects. Using ALE, we analyzed the BOLD response during power, precision, static and dynamic grip in a range of forces and age in right handed healthy individuals without physical impairment, cardiovascular or neurological dysfunction using a variety of grip tools, feedback and experimental training. Power grip generates unique activation in the postcentral gyrus (areas 1 and 3b) and precision grip generates unique activation in the supplementary motor area (SMA, area 6) and precentral gyrus (area 4a). Dynamic handgrip generates unique activation in the precentral gyrus (area 4p) and SMA (area 6) and of particular interest, both dynamic and static grip share activation in the area 2 of the postcentral gyrus, an area implicated in the evolution of handgrip. According to effect size analysis, precision and dynamic grip generates stronger activity than power and static, respectively. Our study demonstrates specific differences between grip type and pattern. However, there was a large degree of overlap in the pre and postcentral gyrus, SMA and areas of the frontal-parietal-cerebellar network, which indicates that other mechanisms are potentially involved in regulating handgrip. Further, our study provides empirically based regions of interest, which can be downloaded here within, that can be used to more effectively

  9. Grip Force Adjustments Reflect Prediction of Dynamic Consequences in Varying Gravitoinertial Fields

    Directory of Open Access Journals (Sweden)

    Olivier White

    2018-02-01

    Full Text Available Humans have a remarkable ability to adjust the way they manipulate tools through a genuine regulation of grip force according to the task. However, rapid changes in the dynamical context may challenge this skill, as shown in many experimental approaches. Most experiments adopt perturbation paradigms that affect only one sensory modality. We hypothesize that very fast adaptation can occur if coherent information from multiple sensory modalities is provided to the central nervous system. Here, we test whether participants can switch between different and never experienced dynamical environments induced by centrifugation of the body. Seven participants lifted an object four times in a row successively in 1, 1.5, 2, 2.5, 2, 1.5, and 1 g. We continuously measured grip force, load force and the gravitoinertial acceleration that was aligned with body axis (perceived gravity. Participants adopted stereotyped grasping movements immediately upon entry in a new environment and needed only one trial to adapt grip forces to a stable performance in each new gravity environment. This result was underlined by good correlations between grip and load forces in the first trial. Participants predictively applied larger grip forces when they expected increasing gravity steps. They also decreased grip force when they expected decreasing gravity steps, but not as much as they could, indicating imperfect anticipation in that condition. The participants' performance could rather be explained by a combination of successful scaling of grip force according to gravity changes and a separate safety factor. The data suggest that in highly unfamiliar dynamic environments, grip force regulation is characterized by a combination of a successful anticipation of the experienced environmental condition, a safety factor reflecting strategic response to uncertainties about the environment and rapid feedback mechanisms to optimize performance under constant conditions.

  10. Hand-grip isometric strength in judo

    Directory of Open Access Journals (Sweden)

    Juan G Bonitch-Góngora

    2014-02-01

    Full Text Available The grip is an important technical and tactical aspect through which the judokas dominate the adversary, hindering the application of appropriate techniques and favoring their own attack. The judokas must have high levels of isometric force and endurance to this type of force on the gripping muscles of the forearms, as one of the key aspects for success. This article reviews the grip muscular strength and endurance profiles of judokas of different groups (gender, age and competitive level. In general, the peak isometric strength of elite judokas has not changed in the last 40 years and is similar to that reached by non-elite judokas or even registered in large populations. This indicate that the evaluation of the isometric hand grip endurance may be a more relevant parameter than the peak isometric force in judokas, as during the bouts the grip must be maintained for relatively long periods of time and the maximum force cannot be maintained for long. However there are few studies on the ability to resist successive isometric handgrip stress in judokas.

  11. The interdigital brace and other grips for termite nest perforation by chimpanzees of the Goualougo Triangle, Republic of Congo.

    Science.gov (United States)

    Lesnik, Julie J; Sanz, Crickette M; Morgan, David B

    2015-06-01

    Studies of chimpanzee termite foraging enlighten our understanding of early hominin tool use not only by modeling the cognitive ability of our ancestors but also by emphasizing the possible role of social insects in the hominin diet. The chimpanzees of the Goualougo Triangle are known to have one of the largest and most complex tool repertoires reported for wild chimpanzees. One tool set habitually used by this population includes a perforating tool to penetrate the hard outer crust of elevated termite nests before fishing for termite prey with an herbaceous stem. Here, we report the variation present in the grips used on the perforating tool. Our analysis of video recordings of chimpanzee visitation to termite nests over a 3-year period shows that these chimpanzees use a variety of grips to navigate the challenges encountered in opening a termite nest. For situations in which the soil is most hardened, perforating requires force and a power grip is often used. When the soil in the passageway is loose, precision grips are suitable for the task. One of the preferred grips reported here is an interdigital brace, which has previously been described in studies of how some people hold a pencil. In this study, for the first time, the interdigital brace has been thoroughly described for chimpanzees. The various strategies and grips used during perforation emphasize the importance of termites as a nutritional resource that should be considered more strongly as a food used by early hominins. © 2015 Wiley Periodicals, Inc.

  12. Estimating thumb–index finger precision grip and manipulation potential in extant and fossil primates

    Science.gov (United States)

    Feix, Thomas; Kivell, Tracy L.; Pouydebat, Emmanuelle; Dollar, Aaron M.

    2015-01-01

    Primates, and particularly humans, are characterized by superior manual dexterity compared with other mammals. However, drawing the biomechanical link between hand morphology/behaviour and functional capabilities in non-human primates and fossil taxa has been challenging. We present a kinematic model of thumb–index precision grip and manipulative movement based on bony hand morphology in a broad sample of extant primates and fossil hominins. The model reveals that both joint mobility and digit proportions (scaled to hand size) are critical for determining precision grip and manipulation potential, but that having either a long thumb or great joint mobility alone does not necessarily yield high precision manipulation. The results suggest even the oldest available fossil hominins may have shared comparable precision grip manipulation with modern humans. In particular, the predicted human-like precision manipulation of Australopithecus afarensis, approximately one million years before the first stone tools, supports controversial archaeological evidence of tool-use in this taxon. PMID:25878134

  13. GRIP DC-8 NAVIGATION AND HOUSEKEEPING DATA V1

    Data.gov (United States)

    National Aeronautics and Space Administration — The GRIP DC-8 Navigation and Housekeeping Data contains aircraft navigational data obtained during the GRIP campaign (15 Aug 2010 - 30 Sep 2010). The major goal was...

  14. ANALYSIS OF POWER GRIP AND PINCH GRIP AMONG HEALTH CARE PROFESSIONALS

    Directory of Open Access Journals (Sweden)

    Zakariya M P

    2016-02-01

    Full Text Available Background: Grip and pinch strength are commonly employed indices of strength used in hand evaluations. Pinch grip and power grip strengths are used as indices of strength in hand therapy assessments. For all professions grip strength is an important criterion to be successful in their profession. Such phenomena may be explained by differences in nature of work, working environment, and objects workers handle. Method: 200 healthy subjects, satisfying the selection criteria were included and assessed with standardized procedure for power grip and pinch grip (lateral pinch, pad-pad, and tip-tip strength. They were divided in four groups, 50 group each according to profession i.e. medical surgeons, dentist, physiotherapists and nurses. Results: The mean power grip strength shows highly significant difference between medical vs. dental (p>0.01 and medical vs. physiotherapy group (p> 0.05 .The mean lateral pinch strength shows there is highly significant difference (p< 0.001 between dental vs. nursing profession and dental vs. physiotherapy group. No significant difference among other groups. The mean pad-pad pinch strength shows there is significant difference between dental vs. nursing (p< 0.05 and dental vs physiotherapy group (p< 0.05. The mean Tip-Tip pinch strength shows there is significant difference between dental vs nursing profession(p< 0.05 and dental vs. physiotherapy(p< 0.05. No significant different among other groups. Conclusion: Surgeons have highest power grip strength followed by Nursing, Physiotherapy and Dental professionals. Dentists have the maximum pinch strength in all three positions, followed by Surgeons, Nurses and Physiotherapists. Surgeons have maximum pinch strength next to Dentists.

  15. G×E Interaction Influences Trajectories of Hand Grip Strength

    DEFF Research Database (Denmark)

    Petersen, Inge; Pedersen, Nancy L; Rantanen, Taina

    2016-01-01

    Age-related decline in grip strength predicts later life disability, frailty, lower well-being and cognitive change. While grip strength is heritable, genetic influence on change in grip strength has been relatively ignored, with non-shared environmental influence identified as the primary contri...

  16. Variability of grip kinetics during adult signature writing.

    Directory of Open Access Journals (Sweden)

    Bassma Ghali

    Full Text Available Grip kinetics and their variation are emerging as important considerations in the clinical assessment of handwriting pathologies, fine motor rehabilitation, biometrics, forensics and ergonomic pen design. This study evaluated the intra- and inter-participant variability of grip shape kinetics in adults during signature writing. Twenty (20 adult participants wrote on a digitizing tablet using an instrumented pen that measured the forces exerted on its barrel. Signature samples were collected over 10 days, 3 times a day, to capture temporal variations in grip shape kinetics. A kinetic topography (i.e., grip shape image was derived per signature by time-averaging the measured force at each of 32 locations around the pen barrel. The normalized cross correlations (NCC of grip shape images were calculated within- and between-participants. Several classification algorithms were implemented to gauge the error rate of participant discrimination based on grip shape kinetics. Four different grip shapes emerged and several participants made grip adjustments (change in grip shape or grip height or rotated the pen during writing. Nonetheless, intra-participant variation in grip kinetics was generally much smaller than inter-participant force variations. Using the entire grip shape images as a 32-dimensional input feature vector, a K-nearest neighbor classifier achieved an error rate of 1.2±0.4% in discriminating among participants. These results indicate that writers had unique grip shape kinetics that were repeatable over time but distinct from those of other participants. The topographic analysis of grip kinetics may inform the development of personalized interventions or customizable grips in clinical and industrial applications, respectively.

  17. ASSESSMENT OF GRIP FORCE CONTROL IN PATIENTS WITH MUSCULAR DYSTROPHY

    Directory of Open Access Journals (Sweden)

    Gregorij Kurillo

    2004-12-01

    Full Text Available Background. The majority of hand functionality tests are based on qualitative assessment which largely depends on the experience of the therapist. Computer-assisted methods can provide more objective and accurate measurements of the grip force and other parameters related to grasping.Methods. We analysed the grip force control in 12 patients with muscular dystrophy using the tracking system developed. The system consists of a grip-measuring device with endobjects assessing the force applied in different grips. The device was used as input to a tracking task where the patient applied the grip force according to the visual feedback from the computer screen. Each patient performed two tasks which consisted of tracking a ramp and sinus target.Results. We analysed the maximal grip force as assessed in the ramp task and the tracking accuracy of the sinus task. The results are compared among five different grips (cylindrical, lateral, palmar, pinch and spherical grip, applied with dominant and non-dominant hand. The results show no significant difference in tracking accuracy between the dominant and non-dominant hand.Conclusions. The results obtained in tracking the ramp target showed that the method could be used for the assessment of the muscle fatigue, providing quantitative information on muscle capacity. The results of the sinus-tracking task showed that the method can evaluate the grip force control in different types of grips, providing information on hand dexterity, muscle activation patterns or tremor.

  18. Contact pressure measurement in hand tool evaluation studies

    NARCIS (Netherlands)

    Kuijt-Evers, L.F.M.; Bosch, T.

    2006-01-01

    In hand tool evaluation studies, several objective measurements are used. Grip force distribution and grip force are important as they give feedback about the force which has to be performed with the hand on the handle. A measurement technique -which is related to grip force measurement- is contact

  19. Gripping means for fuel assemblies of nuclear reactor

    International Nuclear Information System (INIS)

    Batjukov, V.I.; Fadeev, A.I.; Shkhian, T.G.; Vjugov, O.N.

    1980-01-01

    The proposed gripping means for fuel assemblies of a nuclear reactor comprises a housing, whereupon there is movably mounted a slider provided with longitudinally extending slots to receive gripping jaws whose tails are pivotably secured to the housing of the gripping means. On one side, the end faces of the longitudinally extending slots are slanted with respect to the longitudinal axis of the gripping means and come in contact with the teeth of the gripping jaws provided on the end which is opposite to the tail, whereby the jaws open as the slider and housing of the gripping means moves relative to each other so that the teeth are received in an internal groove provided in the head of the fuel assembly

  20. Systems and Methods for Gravity-Independent Gripping and Drilling

    Science.gov (United States)

    Parness, Aaron (Inventor); Frost, Matthew A. (Inventor); Thatte, Nitish (Inventor); King, Jonathan P. (Inventor)

    2016-01-01

    Systems and methods for gravity independent gripping and drilling are described. The gripping device can also comprise a drill or sampling devices for drilling and/or sampling in microgravity environments, or on vertical or inverted surfaces in environments where gravity is present. A robotic system can be connected with the gripping and drilling devices via an ankle interface adapted to distribute the forces realized from the robotic system.

  1. GRIP LIDAR ATMOSPHERIC SENSING EXPERIMENT (LASE) V1

    Data.gov (United States)

    National Aeronautics and Space Administration — The GRIP Lidar Atmospheric Sensing Experiment (LASE) dataset was collected by NASA's Lidar Atmospheric Sensing Experiment (LASE) system, which is an airborne...

  2. Grip-pattern recognition: Applied to a smart gun

    NARCIS (Netherlands)

    Shang, X.

    2008-01-01

    In our work the verification performance of a biometric recognition system based on grip patterns, as part of a smart gun for use by the police ocers, has been investigated. The biometric features are extracted from a two-dimensional pattern of the pressure, exerted on the grip of a gun by the hand

  3. Biometric verification based on grip-pattern recognition

    NARCIS (Netherlands)

    Veldhuis, Raymond N.J.; Bazen, A.M.; Kauffman, J.A.; Hartel, Pieter H.; Delp, Edward J.; Wong, Ping W.

    This paper describes the design, implementation and evaluation of a user-verification system for a smart gun, which is based on grip-pattern recognition. An existing pressure sensor consisting of an array of 44 x 44 piezoresistive elements is used to measure the grip pattern. An interface has been

  4. Algorithm Design for Grip-Pattern Verification in Smart Gun

    NARCIS (Netherlands)

    Shang, X.; Veldhuis, Raymond N.J.; Bazen, A.M.; Ganzevoort, W.P.T.

    2005-01-01

    The Secure Grip project1 focuses on the development of a hand-grip pattern recognition system, as part of the smart gun. Its target customer is the police. To explore the authentication performance of this system, we collected data from a group of police officers, and made authentication simulations

  5. Tensile testing grips are easily assembled under liquid nitrogen

    Science.gov (United States)

    Skalka, R. J.; Vandergrift, E. F.

    1967-01-01

    Split-screw grips for tensile testing provide uniform loading on the specimen shoulders. Holes in the heads enable the screws and specimen to be threaded as an assembly into a grip body, closely controlled guides and seats afford positive seating, and precision machining of mating surfaces minimizes misalignment effects.

  6. Biometric verification based on grip-pattern recognition

    NARCIS (Netherlands)

    Veldhuis, Raymond N.J.; Bazen, A.M.; Kauffman, J.A.; Hartel, Pieter H.

    This paper describes the design, implementation and evaluation of a user-verification system for a smart gun, which is based on grip-pattern recognition. An existing pressure sensor consisting of an array of 44 £ 44 piezoresistive elements is used to measure the grip pattern. An interface has been

  7. Estimating thumb-index finger precision grip and manipulation potential in extant and fossil primates.

    Science.gov (United States)

    Feix, Thomas; Kivell, Tracy L; Pouydebat, Emmanuelle; Dollar, Aaron M

    2015-05-06

    Primates, and particularly humans, are characterized by superior manual dexterity compared with other mammals. However, drawing the biomechanical link between hand morphology/behaviour and functional capabilities in non-human primates and fossil taxa has been challenging. We present a kinematic model of thumb-index precision grip and manipulative movement based on bony hand morphology in a broad sample of extant primates and fossil hominins. The model reveals that both joint mobility and digit proportions (scaled to hand size) are critical for determining precision grip and manipulation potential, but that having either a long thumb or great joint mobility alone does not necessarily yield high precision manipulation. The results suggest even the oldest available fossil hominins may have shared comparable precision grip manipulation with modern humans. In particular, the predicted human-like precision manipulation of Australopithecus afarensis, approximately one million years before the first stone tools, supports controversial archaeological evidence of tool-use in this taxon. © 2015 The Author(s) Published by the Royal Society. All rights reserved.

  8. A firm political grip on the market

    International Nuclear Information System (INIS)

    Bakken, Stein Arne

    2003-01-01

    In Norway, there is a strong political grip on the energy supply industry. The market is going to play a marginal role. The article deals with three scenarios for what the Norwegian energy supply might look like in 2005 as envisaged by a group of researchers in a comprehensive project carried out by ECON. The first scenario, ''The Market Place'', shows the development of the energy supply from regulation to a free market in the wake of the new Energy Act. According to this scenario, by 2005 the market should be well established as a form of control. The second scenario, ''The Norwegian Way'', shows the way of the energy supply from a free market to regulation. The third scenario is ''The Field of Force'' and shows how the energy supply develops into a strong energy industrial complex; this is the scenario that definitely has not come true. The most likely scenario to come true in ten years is probably a mixture of ''The Market Place'' and ''The Norwegian Way'' with an emphasis on the latter. The trend is clearly for increased political control

  9. GRIP BARBADOS/CAPE VERDE RADIOSONDE V1

    Data.gov (United States)

    National Aeronautics and Space Administration — The GRIP Barbados/Cape Verde radiosonde data set consists of generally two soundings per day (06Z and 12Z) launched from Barbados, and one sounding per day (12Z)...

  10. GRIP DOPPLER AEROSOL WIND LIDAR (DAWN) V1

    Data.gov (United States)

    National Aeronautics and Space Administration — The GRIP Doppler Aerosol WiNd Lidar (DAWN) Dataset was collected by the Doppler Aerosol WiNd (DAWN), a pulsed lidar, which operated aboard a NASA DC-8 aircraft...

  11. Getting a grip on affordances, attention and visual fields

    OpenAIRE

    Linden, Lotje van der; Theeuwes, Jan; Ellis, Rob

    2013-01-01

    van der Linden, L., Theeuwes, J., & Ellis, R. (2012). Getting a grip on affordances, attention, and visual fields. Poster presented at the 2012 William James Graduate School Symposium, Amsterdam, The Netherlands.

  12. GRIP DC-8 NAVIGATION AND HOUSEKEEPING DATA V1

    Data.gov (United States)

    National Aeronautics and Space Administration — This dataset contains aircraft navigational data obtained during the GRIP campaign (15 Aug 2010 - 30 Sep 2010). The NASA DC-8 is outfitted with a navigational...

  13. Anticipatory grip force between 1 and 3g

    Science.gov (United States)

    White, Olivier; Van Loon, ing.. Jack J. W. A.; Thonnard, Jean-Louis; Hermsdorfer, Joachim; Lefevre, Philippe

    One remarkable capacity of utilizing common tools appropriately as soon as we grasp them relies on the ability to determine in advance the grip force (GF) required to handle them in relation to their mechanical properties and the surrounding environment. This anticipatory strategy avoids the uncompressible delays in the feedback system. The predictive control of GF is made possible because the nervous system can learn, store and then select the internal representations of the dynamics of innumerable objects, known as internal models. Beside this flexibility, the nervous system's ability to learn different task dynamics is often limited in classical robotic experiments The environment itself can be profoundly modified in altered gravity or centrifugation. The few studies that investigated motor adaptation in such contexts did not consider the interaction between gravitational phases and even less the transitions across environments. Here, we tested subject's abilities to adapt to levels of gravitational fields generated by a human centrifuge. In Experiment 1, seven subjects performed 4 lifting trials in each gravitational phase (1 to 2.5g and then 2.5 to 1g by steps of 0.5g) with a 0.12 kg instrumented object. In Experiment 2, six subjects performed vertical oscillations of the object during transitions between 1 and 3g (0.5g steps, ascending and descending phases, profile repeated twice). We continuously measured GF, load force (LF) and ambient gravity. We hypothesized that participants were able to predictively adjust GF to the new environment. In Experiment 1, participants adjusted their GF proportionally to gravity and decreased GF across trials within a given gravitational environment. Preload phases decreased over time from 300ms to 50ms irrespective of gravity. We quantified the abilities of participants to switch across environments by subtracting GF recorded in the last trial in the current gravity level from GF during the first trial in the new environment

  14. Handling device with grips operated by a servo-motor

    International Nuclear Information System (INIS)

    Sgarbi, F.; Detriche, J.M.

    1990-01-01

    On grip jaws are set up a detection circuit which allows the rocking of the control system from a control system in position to a control system in clamping strain when an object is held, and then which allows to use them by turns in order to keep only their advantages. A larger light touch handling is obtained. The application of this grip is recommended to catch brittle objects (for handicapped persons by example) [fr

  15. Grip op werkstress. Mindfulness ontstresst maatschappelijk werkers

    Directory of Open Access Journals (Sweden)

    Jen van Horen

    2014-03-01

    Full Text Available Taking control over work related stress. Mindfulness destresses social workersStress is a major social problem. Due to the increasing workload and the content of the work, social workers are at risk to develop stress (symptoms. The physical and psychological consequences of prolonged stress are serious. By living healthy, optimize working conditions and applying mindfulness, stress can be reduced. Mindfulness is an effective and useful way to reduce stress. It increases the resistance of workers against stress, improves brainfunctions and therefore has a positive effect on the performance. These effects are great, but they are still weakly methodologically substantiated. A pilot project within the youthcare though, was enthusiastically received and proves to be effective against stress symptoms. The exercises that are part of this pilot fit well with the needs of employees. For organizations mindfulnesstrainings are a time-and cost-effective way of structural stress prevention.Grip op werkstress. Mindfulness ontstresst maatschappelijk werkersStress is een omvangrijk maatschappelijk probleem. Door de toenemende werkdruk en de inhoud van het werk zijn maatschappelijk werkers een risicogroep om stress en stressklachten te ontwikkelen. De fysieke en psychische gevolgen die langdurige stress met zich meebrengt zijn ernstig. Door gezond te leven, de arbeidsomstandigheden te optimaliseren en mindfulness toe te passen kan stress terug worden gedrongen. Mindfulness is een effectieve en bruikbare manier om stress te verminderen. Het vergroot de weerbaarheid van werknemers tegen stress, het verbetert de hersenwerking en heeft daardoor een positief effect op het functioneren. Grote effecten dus, maar wel nog methodologisch zwak onderbouwd. Een pilot binnen de jeugdzorg op het gebied van mindfulness is enthousiast ontvangen en blijkt effectief tegen stressklachten. De oefeningen die onderdeel uitmaken van deze pilot sluiten goed aan bij de behoeften van

  16. Grip Analysis of Road Surface and Tire Footprint Using FEM

    Science.gov (United States)

    Sabri, M.; Abda, S.

    2018-02-01

    Road grip involve a touch between road pavement and the tire tread pattern. The load bearing surface, which depends on pavement roughness and local pressures in the contact patch. This research conducted to develop a Finite element model for simulating the experimentally testing of asphalt in Jl. AH Nasution Medan, North Sumatera Indonesia base on the value of grip coefficient from various tire loads and the various speed of the vehicle during contact to the road. A tire model and road pavement are developed for the analyses the geometry of tire footprint. The results showed that the greater the mass of car will increase grip coefficient. The coefficient of grip on the road surface contact trough the tire footprint strongly influence the kinetic coefficient of friction at certain speeds. Experimentally show that Concrete road grip coefficient of more than 34% compared to the asphalt road at the same IRI parameters (6-8). Kinetic friction coefficient more than 0.33 was obtained in a asphalt path at a speed of 30-40 Km/hour.

  17. Hand Grip Strength Vs. Sprint Effectiveness in Amputee Soccer Players.

    Science.gov (United States)

    Wieczorek, Marta; Wiliński, Wojciech; Struzik, Artur; Rokita, Andrzej

    2015-11-22

    Amputee soccer is one of the types of soccer designed for the disabled, especially those who have undergone amputations, as well as those with extremity dysfunction. The objective of the study was to find the relationship between hand grip strength and sprint time in amputee soccer players. Thirteen field amputee soccer players participated in the study. A SAEHAN hydraulic hand dynamometer manufactured by Jamar was used for hand grip strength measurements. The sprint running test was conducted over a distance of 30 m. The Fusion Smart Speed System was employed for running time measurements. No statistically significant relationships were found between hand grip strength of the left or right hand, and sprint times over 1, 5, 10, 15, 20, 25 and 30 m. Analysis of the running velocity curve of the subjects showed an interesting profile characterized by a 15 meter-long acceleration phase and a significant velocity increase over a distance of 20 - 25 m. The study suggests that there is no relationship between hand grip strength and sprint effectiveness in amputee soccer players. The specificity of locomotion with the use of elbow crutches among elite Polish amputee soccer players probably accounts for the profile of the sprint velocity curve. Extension of the acceleration phase in the sprint run and a velocity increase in the subsequent part of the run were observed.

  18. Hand Grip Strength Vs. Sprint Effectiveness in Amputee Soccer Players

    Directory of Open Access Journals (Sweden)

    Wieczorek Marta

    2015-12-01

    Full Text Available Amputee soccer is one of the types of soccer designed for the disabled, especially those who have undergone amputations, as well as those with extremity dysfunction. The objective of the study was to find the relationship between hand grip strength and sprint time in amputee soccer players. Thirteen field amputee soccer players participated in the study. A SAEHAN hydraulic hand dynamometer manufactured by Jamar was used for hand grip strength measurements. The sprint running test was conducted over a distance of 30 m. The Fusion Smart Speed System was employed for running time measurements. No statistically significant relationships were found between hand grip strength of the left or right hand, and sprint times over 1, 5, 10, 15, 20, 25 and 30 m. Analysis of the running velocity curve of the subjects showed an interesting profile characterized by a 15 meter-long acceleration phase and a significant velocity increase over a distance of 20 – 25 m. The study suggests that there is no relationship between hand grip strength and sprint effectiveness in amputee soccer players. The specificity of locomotion with the use of elbow crutches among elite Polish amputee soccer players probably accounts for the profile of the sprint velocity curve. Extension of the acceleration phase in the sprint run and a velocity increase in the subsequent part of the run were observed.

  19. Grip and Pinch Strength Norms for Michigan Workers

    Directory of Open Access Journals (Sweden)

    Joel M. Phillips M.S., OTRL

    2013-06-01

    Full Text Available The purpose of this study was to create a norm reference of current grip and pinch strength norms for working-age Michigan adults. This normative study included a convenience sample of 179 volunteers who were employees at car plants in South East Michigan or hospital sites in West Michigan. Participants’ ages ranged from between 20 and 62 years of age with a mean age of 49.15 years. There were 78 females (44% and 101 males (56%. Subjects were classified by gender and in the age categories of ages 20 to 49 years and ages 50-62 years. Grip and pinch strength norms were collected following the American Society of Hand Therapy protocol. The norms from these working adults were calculated with descriptive statistics for males and females in two age classifications: ages 20 to 49 and ages 50 to 62 years. Standard Errors (SE are better than the 1985 norms for both males and females ages 20 to 49 years. SEs are higher than the ages 20 to 49 years’ norms for the ages 50 to 62 years age categories in both males and females. These norms offer a point of comparison for clinicians to use for clients in Michigan who are ages 20 to 62 years and who have a goal to improve their grip strength. Clients’ grip and pinch strength could be compared to their age level or gender norms using the comparison for one standard deviation above, below, or at the means.

  20. Wearable flex sensor system for multiple badminton player grip identification

    Science.gov (United States)

    Jacob, Alvin; Zakaria, Wan Nurshazwani Wan; Tomari, Mohd Razali Bin Md; Sek, Tee Kian; Suberi, Anis Azwani Muhd

    2017-09-01

    This paper focuses on the development of a wearable sensor system to identify the different types of badminton grip that is used by a player during training. Badminton movements and strokes are fast and dynamic, where most of the involved movement are difficult to identify with the naked eye. Also, the usage of high processing optometric motion capture system is expensive and causes computational burden. Therefore, this paper suggests the development of a sensorized glove using flex sensor to measure a badminton player's finger flexion angle. The proposed Hand Monitoring Module (HMM) is connected to a personal computer through Bluetooth to enable wireless data transmission. The usability and feasibility of the HMM to identify different grip types were examined through a series of experiments, where the system exhibited 70% detection ability for the five different grip type. The outcome plays a major role in training players to use the proper grips for a badminton stroke to achieve a more powerful and accurate stroke execution.

  1. Grip strength as a frailty diagnostic component in geriatric inpatients

    Directory of Open Access Journals (Sweden)

    Dudzińska-Griszek J

    2017-07-01

    Full Text Available Joanna Dudzińska-Griszek, Karolina Szuster, Jan Szewieczek Department of Geriatrics, School of Health Sciences in Katowice, Medical University of Silesia, Katowice, Poland Background: Frailty has emerged as a key medical syndrome predictive of comorbidity, disability, institutionalization and death. As a component of the five frailty phenotype diagnostic criteria, patient grip strength deserves attention as a simple and objective measure of the frailty syndrome. The aim of this study was to assess conditions that influence grip strength in geriatric inpatients.Patients and methods: The study group consisted of 80 patients aged 78.6±7.0 years ( X ± SD, with 68.8% women, admitted to the Department of Geriatrics. A comprehensive geriatric assessment was complemented with assessment for the frailty phenotype as described by Fried et al for all patients in the study group. Functional assessment included Barthel Index of Activities of Daily Living (Barthel Index, Instrumental Activities of Daily Living Scale and Mini-Mental State Examination.Results: Three or more frailty criteria were positive in 32 patients (40%, while 56 subjects (70% fulfilled the frailty criterion of weakness (grip strength test. Multivariate linear regression analysis revealed that two independent measures showed positive association with grip strength – Mini-Mental State Examination score (β=0.239; P=0.001 and statin use (β=0.213; P=0.002 – and four independent measures were negatively associated with grip strength – female sex (β=–0.671; P<0.001, C-reactive protein (β=–0.253; P<0.001, prior myocardial infarction (β=–0.190; P=0.006 and use of an antidepressant (β=–0.163; P=0.018. Low physical activity was identified as the only independent qualitative frailty component associated with 2-year mortality in multivariate logistic regression analysis after adjustment for age and sex (odds ratio =6.000; 95% CI =1.357–26.536; P=0.018.Conclusion: Cognitive

  2. Study on the collision-mechanical properties of tomatoes gripped by ...

    African Journals Online (AJOL)

    The data of collision-mechanical property of tomatoes gripped by robot fingers are important for the gripping control of tomato harvesting robot. In the study, tests of controlling the fingers to grip tomatoes were conducted to ascertain the effects of input current, motor speed and impact positions on the impact force of fingers ...

  3. Fingers' vibration transmission and grip strength preservation performance of vibration reducing gloves.

    Science.gov (United States)

    Hamouda, K; Rakheja, S; Dewangan, K N; Marcotte, P

    2018-01-01

    The vibration isolation performances of vibration reducing (VR) gloves are invariably assessed in terms of power tools' handle vibration transmission to the palm of the hand using the method described in ISO 10819 (2013), while the nature of vibration transmitted to the fingers is ignored. Moreover, the VR gloves with relatively low stiffness viscoelastic materials affect the grip strength in an adverse manner. This study is aimed at performance assessments of 12 different VR gloves on the basis of handle vibration transmission to the palm and the fingers of the gloved hand, together with reduction in the grip strength. The gloves included 3 different air bladder, 3 gel, 3 hybrid, and 2 gel-foam gloves in addition to a leather glove. Two Velcro finger adapters, each instrumented with a three-axis accelerometer, were used to measure vibration responses of the index and middle fingers near the mid-phalanges. Vibration transmitted to the palm was measured using the standardized palm adapter. The vibration transmissibility responses of the VR gloves were measured in the laboratory using the instrumented cylindrical handle, also described in the standard, mounted on a vibration exciter. A total of 12 healthy male subjects participated in the study. The instrumented handle was also used to measure grip strength of the subjects with and without the VR gloves. The results of the study showed that the VR gloves, with only a few exceptions, attenuate handle vibration transmitted to the fingers only in the 10-200 Hz and amplify middle finger vibration at frequencies exceeding 200 Hz. Many of the gloves, however, provided considerable reduction in vibration transmitted to the palm, especially at higher frequencies. These suggest that the characteristics of vibration transmitted to fingers differ considerably from those at the palm. Four of the test gloves satisfied the screening criteria of the ISO 10819 (2013) based on the palm vibration alone, even though these caused

  4. Effects of hyperthyroidism on hand grip strength and function

    OpenAIRE

    Esra Erkol İnal, MD; Alparslan Bayram Çarlı, MD; Sultan Çanak, MD; Oğuzhan Aksu, MD; Banu Kale Köroğlu, MD; Serpil Savaş

    2015-01-01

    Hyperthyroidism is a pathologic condition in which the body is exposed to excessive amounts of circulating thyroid hormones. Skeletal muscle is one of the major target organs of thyroid hormones. We evaluated hand grip strength and function in patients with overt hyperthyroidism. Fifty-one patients newly diagnosed with hyperthyroidism and 44 healthy controls participated in this study. Age, height, weight, and dominant hand of all participants were recorded. The diagnosis of hyperthyroidism w...

  5. Improved Friction Joint With Self-Locking Grips

    DEFF Research Database (Denmark)

    Costache, Andrei; Glejbøl, Kristian; Sivebæk, Ion Marius

    2016-01-01

    Flexible risers are used in the oil industry to transport liquids and gas from the seafloorto extraction and production equipment at the sea surface. Ongoing research aims at using composite materials instead of steel, in order to reduce weight and increase stiffness. Ensuring an optimal load......-depth understanding of the influence between friction, geometrical parameters,and performance, making it possible to optimize the design. Results show that this grip system offers immediate technical applications, in a variety of conditions....

  6. The end-state comfort effect in bimanual grip selection.

    Science.gov (United States)

    Fischman, Mark G; Stodden, David F; Lehman, Davana M

    2003-03-01

    During a unimanual grip selection task in which people pick up a lightweight dowel and place one end against targets at variable heights, the choice of hand grip (overhand vs. underhand) typically depends on the perception of how comfortable the arm will be at the end of the movement: an end-state comfort effect. The two experiments reported here extend this work to bimanual tasks. In each experiment, 26 right-handed participants used their left and right hands to simultaneously pick up two wooden dowels and place either the right or left end against a series of 14 targets ranging from 14 to 210 cm above the floor. These tasks were performed in systematic ascending and descending orders in Experiment 1 and in random order in Expiment 2. Results were generally consistent with predictions of end-state comfort in that, for the extreme highest and lowest targets, participants tended to select opposite grips with each hand. Taken together, our findings are consistent with the concept of constraint hierarchies within a posture-based motion-planning model.

  7. Tyre-road grip coefficient assessment - Part II: online estimation using instrumented vehicle, extended Kalman filter, and neural network

    Science.gov (United States)

    Luque, Pablo; Mántaras, Daniel A.; Fidalgo, Eloy; Álvarez, Javier; Riva, Paolo; Girón, Pablo; Compadre, Diego; Ferran, Jordi

    2013-12-01

    The main objective of this work is to determine the limit of safe driving conditions by identifying the maximal friction coefficient in a real vehicle. The study will focus on finding a method to determine this limit before reaching the skid, which is valuable information in the context of traffic safety. Since it is not possible to measure the friction coefficient directly, it will be estimated using the appropriate tools in order to get the most accurate information. A real vehicle is instrumented to collect information of general kinematics and steering tie-rod forces. A real-time algorithm is developed to estimate forces and aligning torque in the tyres using an extended Kalman filter and neural networks techniques. The methodology is based on determining the aligning torque; this variable allows evaluation of the behaviour of the tyre. It transmits interesting information from the tyre-road contact and can be used to predict the maximal tyre grip and safety margin. The maximal grip coefficient is estimated according to a knowledge base, extracted from computer simulation of a high detailed three-dimensional model, using Adams® software. The proposed methodology is validated and applied to real driving conditions, in which maximal grip and safety margin are properly estimated.

  8. Hand grips strength effect on motor function in human brain using fMRI: a pilot study

    International Nuclear Information System (INIS)

    Ismail, S S; Mohamad, M; Syazarina, S O; Nafisah, W Y

    2014-01-01

    Several methods of motor tasks for fMRI scanning have been evolving from simple to more complex tasks. Motor tasks on upper extremity were applied in order to excite the increscent of motor activation on contralesional and ipsilateral hemispheres in brain. The main objective of this study is to study the different conditions for motor tasks on upper extremity that affected the brain activation. Ten healthy right handed with normal vision (3 male and 7 female, age range=20-30 years, mean=24.6 years, SD=2.21) participated in this study. Prior to the scanning, participants were trained on hand grip tasks using rubber ball and pressure gauge tool outside the scanner. During fMRI session, a block design with 30-s task blocks and alternating 30-s rest periods was employed while participants viewed a computer screen via a back projection-mirror system and instructed to follow the instruction by gripping their hand with normal and strong grips using a rubber ball. Statistical Parametric mapping (SPM8) software was used to determine the brain activation. Both tasks activated the primary motor (M1), supplementary motor area (SMA), dorsal and ventral of premotor cortex area (PMA) in left hemisphere while in right hemisphere the area of primary motor (M1) somatosensory was activated. However, the comparison between both tasks revealed that the strong hand grip showed the higher activation at M1, PMA and SMA on left hemisphere and also the area of SMA on right hemisphere. Both conditions of motor tasks could provide insights the functional organization on human brain

  9. Hand grips strength effect on motor function in human brain using fMRI: a pilot study

    Science.gov (United States)

    Ismail, S. S.; Mohamad, M.; Syazarina, S. O.; Nafisah, W. Y.

    2014-11-01

    Several methods of motor tasks for fMRI scanning have been evolving from simple to more complex tasks. Motor tasks on upper extremity were applied in order to excite the increscent of motor activation on contralesional and ipsilateral hemispheres in brain. The main objective of this study is to study the different conditions for motor tasks on upper extremity that affected the brain activation. Ten healthy right handed with normal vision (3 male and 7 female, age range=20-30 years, mean=24.6 years, SD=2.21) participated in this study. Prior to the scanning, participants were trained on hand grip tasks using rubber ball and pressure gauge tool outside the scanner. During fMRI session, a block design with 30-s task blocks and alternating 30-s rest periods was employed while participants viewed a computer screen via a back projection-mirror system and instructed to follow the instruction by gripping their hand with normal and strong grips using a rubber ball. Statistical Parametric mapping (SPM8) software was used to determine the brain activation. Both tasks activated the primary motor (M1), supplementary motor area (SMA), dorsal and ventral of premotor cortex area (PMA) in left hemisphere while in right hemisphere the area of primary motor (M1) somatosensory was activated. However, the comparison between both tasks revealed that the strong hand grip showed the higher activation at M1, PMA and SMA on left hemisphere and also the area of SMA on right hemisphere. Both conditions of motor tasks could provide insights the functional organization on human brain.

  10. Discrimination of handlebar grip samples by fourier transform infrared microspectroscopy analysis and statistics

    Directory of Open Access Journals (Sweden)

    Zeyu Lin

    2017-01-01

    Full Text Available In this paper, the authors presented a study on the discrimination of handlebar grip samples, to provide effective forensic science service for hit and run traffic cases. 50 bicycle handlebar grip samples, 49 electric bike handlebar grip samples, and 96 motorcycle handlebar grip samples have been randomly collected by the local police in Beijing (China. Fourier transform infrared microspectroscopy (FTIR was utilized as analytical technology. Then, target absorption selection, data pretreatment, and discrimination of linked samples and unlinked samples were chosen as three steps to improve the discrimination of FTIR spectrums collected from different handlebar grip samples. Principal component analysis and receiver operating characteristic curve were utilized to evaluate different data selection methods and different data pretreatment methods, respectively. It is possible to explore the evidential value of handlebar grip residue evidence through instrumental analysis and statistical treatments. It will provide a universal discrimination method for other forensic science samples as well.

  11. Finger pad friction and its role in grip and touch

    Science.gov (United States)

    Adams, Michael J.; Johnson, Simon A.; Lefèvre, Philippe; Lévesque, Vincent; Hayward, Vincent; André, Thibaut; Thonnard, Jean-Louis

    2013-01-01

    Many aspects of both grip function and tactile perception depend on complex frictional interactions occurring in the contact zone of the finger pad, which is the subject of the current review. While it is well established that friction plays a crucial role in grip function, its exact contribution for discriminatory touch involving the sliding of a finger pad is more elusive. For texture discrimination, it is clear that vibrotaction plays an important role in the discriminatory mechanisms. Among other factors, friction impacts the nature of the vibrations generated by the relative movement of the fingertip skin against a probed object. Friction also has a major influence on the perceived tactile pleasantness of a surface. The contact mechanics of a finger pad is governed by the fingerprint ridges and the sweat that is exuded from pores located on these ridges. Counterintuitively, the coefficient of friction can increase by an order of magnitude in a period of tens of seconds when in contact with an impermeably smooth surface, such as glass. In contrast, the value will decrease for a porous surface, such as paper. The increase in friction is attributed to an occlusion mechanism and can be described by first-order kinetics. Surprisingly, the sensitivity of the coefficient of friction to the normal load and sliding velocity is comparatively of second order, yet these dependencies provide the main basis of theoretical models which, to-date, largely ignore the time evolution of the frictional dynamics. One well-known effect on taction is the possibility of inducing stick–slip if the friction decreases with increasing sliding velocity. Moreover, the initial slip of a finger pad occurs by the propagation of an annulus of failure from the perimeter of the contact zone and this phenomenon could be important in tactile perception and grip function. PMID:23256185

  12. Finger pad friction and its role in grip and touch.

    Science.gov (United States)

    Adams, Michael J; Johnson, Simon A; Lefèvre, Philippe; Lévesque, Vincent; Hayward, Vincent; André, Thibaut; Thonnard, Jean-Louis

    2013-03-06

    Many aspects of both grip function and tactile perception depend on complex frictional interactions occurring in the contact zone of the finger pad, which is the subject of the current review. While it is well established that friction plays a crucial role in grip function, its exact contribution for discriminatory touch involving the sliding of a finger pad is more elusive. For texture discrimination, it is clear that vibrotaction plays an important role in the discriminatory mechanisms. Among other factors, friction impacts the nature of the vibrations generated by the relative movement of the fingertip skin against a probed object. Friction also has a major influence on the perceived tactile pleasantness of a surface. The contact mechanics of a finger pad is governed by the fingerprint ridges and the sweat that is exuded from pores located on these ridges. Counterintuitively, the coefficient of friction can increase by an order of magnitude in a period of tens of seconds when in contact with an impermeably smooth surface, such as glass. In contrast, the value will decrease for a porous surface, such as paper. The increase in friction is attributed to an occlusion mechanism and can be described by first-order kinetics. Surprisingly, the sensitivity of the coefficient of friction to the normal load and sliding velocity is comparatively of second order, yet these dependencies provide the main basis of theoretical models which, to-date, largely ignore the time evolution of the frictional dynamics. One well-known effect on taction is the possibility of inducing stick-slip if the friction decreases with increasing sliding velocity. Moreover, the initial slip of a finger pad occurs by the propagation of an annulus of failure from the perimeter of the contact zone and this phenomenon could be important in tactile perception and grip function.

  13. Improvements in or relating to gripping means for handling nuclear reactor fuel assemblies

    International Nuclear Information System (INIS)

    Batjukov, V.I.; Vjugov, O.N.; Fadeev, A.I.; Shkhian, T.G.

    1980-01-01

    A gripping means for handling fuel assemblies, the heads of which are internally recessed to receive gripping jaws, forms part of a reactor refuelling machine and is telescopically accommodated within a manipulator tube of the machine. A through hole is provided to allow cooling medium to be passed through the fuel assemblies to remove afterheat when the gripping means is used to transfer assemblies from a reactor core to spent fuel storage sockets. (author)

  14. GRIP Database original data - GRIPDB | LSDB Archive [Life Science Database Archive metadata

    Lifescience Database Archive (English)

    Full Text Available switchLanguage; BLAST Search Image Search Home About Archive Update History Data List Contact us GRI...PDB GRIP Database original data Data detail Data name GRIP Database original data DOI 10....18908/lsdba.nbdc01665-006 Description of data contents GRIP Database original data It consists of data table...s and sequences. Data file File name: gripdb_original_data.zip File URL: ftp://ftp.biosciencedbc.jp/archive/gripdb/LATEST/gri...e Database Description Download License Update History of This Database Site Policy | Contact Us GRIP Database original data - GRIPDB | LSDB Archive ...

  15. Contribution of the Cerebellum in Cue-Dependent Force Changes During an Isometric Precision Grip Task.

    Science.gov (United States)

    Kutz, Dieter F; Schmid, Barbara C; Meindl, Tobias; Timmann, Dagmar; Kolb, Florian P

    2016-08-01

    The "raspberry task" represents a precision grip task that requires continuous adjustment of grip forces and pull forces. During this task, subjects use a specialised grip rod and have to increase the pull force linearly while the rod is locked. The positions of the fingers are unrestrained and freely selectable. From the finger positions and the geometry of the grip rod, a physical lever was derived which is a comprehensive measurement of the subject's grip behaviour. In this study, the involvement of the cerebellum in establishing cued force changes (CFC) was examined. The auditory stimulus was associated with a motor behaviour that has to be readjusted during an ongoing movement that already started. Moreover, cerebellar involvement on grip behaviour was examined. The results show that patients presenting with degenerating cerebellar disease (CBL) were able to elicit CFC and were additionally able to optimise grip behaviour by minimising the lever. Comparison of the results of CBL with a control group of healthy subjects showed, however, that the CFC incidence was significantly lower and the reduction of the lever was less in CBL. Hence, the cerebellum is involved not only in the classical conditioning of reflexes but also in the association of sensory stimuli with complex changes in motor behaviour. Furthermore, the cerebellum is involved in the optimisation of grip behaviour during ongoing movements. Recent studies lead to the assumption that the cerebello-reticulo-spinal pathway might be important for the reduced optimisation of grip behaviour in CBL.

  16. Effects of hand grip exercise on shoulder joint internal rotation and external rotation peak torque.

    Science.gov (United States)

    Lee, Dong-Rour; Jong-Soon Kim, Laurentius

    2016-08-10

    The goal of this study is to analyze the effects of hand grip training on shoulder joint internal rotation (IR)/external rotation (ER) peak torque for healthy people. The research was conducted on 23 healthy adults in their 20 s-30 s who volunteered to participate in the experiment. Hand grip power test was performed on both hands of the research subjects before/after the test to study changes in hand grip power. Isokinetic machine was used to measure the concentric IRPT (internal rotation peak torque) and concentric ERPT (external rotation peak torque) at the velocity of 60°/sec, 90°/sec, and 180°/sec before/after the test. Hand grip training was performed daily on the subject's right hand only for four weeks according to exercise program. Finally, hand grip power of both hands and the maximum torque values of shoulder joint IR/ER were measured before/after the test and analyzed. There was a statistically significant difference in the hand grip power of the right hand, which was subject to hand grip training, after the experiment. Also, statistically significant difference for shoulder ERPT was found at 60°/sec. Hand grip training has a positive effect on shoulder joint IRPT/ERPT and therefore can help strengthen muscles around the shoulder without using weight on the shoulder. Consequently, hand grip training would help maintain strengthen the muscles around the shoulder in the early phase of rehabilitation process after shoulder surgery.

  17. Comparative study of maximum isometric grip strength in different sports

    Directory of Open Access Journals (Sweden)

    Noé Gomes Borges Junior

    2009-06-01

    Full Text Available The objective of this study was to compare maximum isometric grip strength (Fmaxbetween different sports and between the dominant (FmaxD and non-dominant (FmaxND hand. Twenty-nine male aikido (AI, jiujitsu (JJ, judo (JU and rowing (RO athletes and 21non-athletes (NA participated in the study. The hand strength test consisted of maintainingmaximum isometric grip strength for 10 seconds using a hand dynamometer. The position of the subjects was that suggested by the American Society of Hand Therapy. Factorial 2X5 ANOVA with Bonferroni correction, followed by a paired t test and Tukey test, was used for statistical analysis. The highest Fmax values were observed for the JJ group when using the dominant hand,followed by the JU, RO, AI and NA groups. Variation in Fmax could be attributed to handdominance (30.9%, sports modality (39.9% and the interaction between hand dominance andsport (21.3%. The present results demonstrated significant differences in Fmax between the JJ and AI groups and between the JJ and NA groups for both the dominant and non-dominant hand. Significant differences in Fmax between the dominant and non-dominant hand were only observed in the AI and NA groups. The results indicate that Fmax can be used for comparisonbetween different sports modalities, and to identify differences between the dominant and nondominanthand. Studies involving a larger number of subjects will permit the identification of differences between other modalities.

  18. The role of left supplementary motor area in grip force scaling.

    Directory of Open Access Journals (Sweden)

    Olivier White

    Full Text Available Skilled tool use and object manipulation critically relies on the ability to scale anticipatorily the grip force (GF in relation to object dynamics. This predictive behaviour entails that the nervous system is able to store, and then select, the appropriate internal representation of common object dynamics, allowing GF to be applied in parallel with the arm motor commands. Although psychophysical studies have provided strong evidence supporting the existence of internal representations of object dynamics, known as "internal models", their neural correlates are still debated. Because functional neuroimaging studies have repeatedly designated the supplementary motor area (SMA as a possible candidate involved in internal model implementation, we used repetitive transcranial magnetic stimulation (rTMS to interfere with the normal functioning of left or right SMA in healthy participants performing a grip-lift task with either hand. TMS applied over the left, but not right, SMA yielded an increase in both GF and GF rate, irrespective of the hand used to perform the task, and only when TMS was delivered 130-180 ms before the fingers contacted the object. We also found that both left and right SMA rTMS led to a decrease in preload phase durations for contralateral hand movements. The present study suggests that left SMA is a crucial node in the network processing the internal representation of object dynamics although further experiments are required to rule out that TMS does not affect the GF gain. The present finding also further substantiates the left hemisphere dominance in scaling GF.

  19. Comparative study of millennials' (age 20-34 years) grip and lateral pinch with the norms.

    Science.gov (United States)

    Fain, Elizabeth; Weatherford, Cara

    Cross-sectional research design. Clinical practice continues to use normative data for grip and pinch measurements that were established in 1985. There is no updated norms despite different hand usage patterns in today's society. Measuring and comparing grip and pinch strengths with normative data is a valid method to determine hand function. This research was implemented to compare the grip and pinch measurements obtained from healthy millennials to the established norms and to describe hand usage patterns for millennials. Grip and lateral pinch measurements were obtained from a sample of 237 healthy millennials (ages 20-34 years). Strength scores were statistically lower that older normative data in all millennial grip strengths, with the exception of the women in the age group of 30-34 years. Specifically, this statistically significant trend was observed in all male grip strengths, as well as in women in the age group of 20-24 years (bilateral grip) and 25-29 years (right grip). However, the lateral pinch data reflected was similar to the older norms with variances of 0.5-1 kg. Current data reflect statistically significant differences from the norms for all male grip measurements, as well as for women in the age group of 20-24 years (bilateral grip) and 25-29 years (right grip). No statistical significance was observed in the independent-sample t tests for the lateral pinch in men of all age groups. Statistical significance was noted for lateral pinch for female age groups for the left hand (20-24 years) and for bilateral lateral pinches (30-34 years). IV. Copyright © 2016 Hanley & Belfus. Published by Elsevier Inc. All rights reserved.

  20. Computational model of precision grip in Parkinson’s disease: A Utility based approach

    Directory of Open Access Journals (Sweden)

    Ankur eGupta

    2013-12-01

    Full Text Available We propose a computational model of Precision Grip (PG performance in normal subjects and Parkinson’s Disease (PD patients. Prior studies on grip force generation in PD patients show an increase in grip force during ON medication and an increase in the variability of the grip force during OFF medication (Fellows et al 1998; Ingvarsson et al 1997. Changes in grip force generation in dopamine-deficient PD conditions strongly suggest contribution of the Basal Ganglia, a deep brain system having a crucial role in translating dopamine signals to decision making. The present approach is to treat the problem of modeling grip force generation as a problem of action selection, which is one of the key functions of the Basal Ganglia. The model consists of two components: 1 the sensory-motor loop component, and 2 the Basal Ganglia component. The sensory-motor loop component converts a reference position and a reference grip force, into lift force and grip force profiles, respectively. These two forces cooperate in grip-lifting a load. The sensory-motor loop component also includes a plant model that represents the interaction between two fingers involved in PG, and the object to be lifted. The Basal Ganglia component is modeled using Reinforcement Learning with the significant difference that the action selection is performed using utility distribution instead of using purely Value-based distribution, thereby incorporating risk-based decision making. The proposed model is able to account for the precision grip results from normal and PD patients accurately (Fellows et. al. 1998; Ingvarsson et. al. 1997. To our knowledge the model is the first model of precision grip in PD conditions.

  1. 16 CFR Figure 5 to Part 1512 - Typical Handbrake Actuator Showing Grip Dimension

    Science.gov (United States)

    2010-01-01

    ... 16 Commercial Practices 2 2010-01-01 2010-01-01 false Typical Handbrake Actuator Showing Grip Dimension 5 Figure 5 to Part 1512 Commercial Practices CONSUMER PRODUCT SAFETY COMMISSION FEDERAL HAZARDOUS... Actuator Showing Grip Dimension EC03OC91.072 ...

  2. Is grip strength a predictor for total muscle strength in healthy children, adolescents, and young adults?

    NARCIS (Netherlands)

    Wind, Anne E.; Takken, Tim; Helders, Paul J. M.; Engelbert, Raoul H. H.

    2010-01-01

    The primary purpose of this study was to examine whether grip strength is related to total muscle strength in children, adolescents, and young adults. The second purpose was to provide reference charts for grip strength, which could be used in the clinical and research setting. This cross-sectional

  3. Hand grip strength in patients with chronic obstructive pulmonary disease

    Directory of Open Access Journals (Sweden)

    Jeong M

    2017-08-01

    Full Text Available Moa Jeong,1 Hyung Koo Kang,1 Pamela Song,2 Hye Kyeong Park,1 Hoon Jung,1 Sung-Soon Lee,1 Hyeon-Kyoung Koo1 1Division of Pulmonary and Critical Care Medicine, Department of Internal Medicine, 2Department of Neurology, Ilsan Paik Hospital, Inje University College of Medicine, Goyang, Republic of Korea Purpose: Hand grip strength (HGS is a simple way of predicting the risk of cardiovascular disease and all-cause mortality in the general population. However, the practical significance of grip strength in patients with COPD is uncertain. The aim of this study was to compare HGS between subjects with and without COPD and to evaluate its clinical relevance in patients with COPD by using a national survey.Methods: Data were collected from the Korean National Health and Nutrition Examination Survey. The study included 421 adults with COPD and 2,542 controls who completed questionnaires, spirometry, and a HGS test. HGS was compared between subjects with and without COPD, and the association between grip strength, lung function, and quality of life (QoL was evaluated.Results: The mean HGS was 33.3±9.1 kg in the COPD group and 29.9±9.5 kg in the non-COPD group; adjusted HGS was 30.9±0.33 kg and 30.9±0.11 kg, respectively (P=0.99. HGS was not related to forced vital capacity (β=0.04, P=0.70 or forced expiratory volume in 1 second (β=0.11, P=0.24 in multivariable analysis. HGS was independently associated with the EQ-5D index, but the relationship was stronger in the COPD group (β=0.30, P<0.001 than in the non-COPD group (β=0.21, P<0.001. The results were similar for each component of the EQ-5D, including mobility (β=-0.25, P<0.001, daily activity (β=-0.19, P=0.01, pain/discomfort (β=-0.32, P<0.001, and anxiety/depression (β=-0.16, P=0.01.Conclusion: HGS was not different between subjects with and without COPD, but was associated with QoL – including mobility, daily activity, pain/discomfort, and anxiety/depression – in patients with COPD. The

  4. Grip type and task goal modify reach-to-grasp performance in post-stroke hemiparesis.

    Science.gov (United States)

    Schaefer, Sydney Y; DeJong, Stacey L; Cherry, Kendra M; Lang, Catherine E

    2012-04-01

    This study investigated whether grip type and/or task goal influenced reaching and grasping performance in poststroke hemiparesis. Sixteen adults with poststroke hemiparesis and twelve healthy adults reached to and grasped a cylindrical object using one of two grip types (3-finger or palmar) to achieve one of two task goals (hold or lift). Performance of the stroke group was characteristic of hemiparetic limb movement during reach-to-grasp, with more curved handpaths and slower velocities compared with the control group. These effects were present regardless of grip type or task goal. Other measures of reaching (reach time and reach velocity at object contact) and grasping (peak thumb-index finger aperture during the reach and peak grip force during the grasp) were differentially affected by grip type, task goal, or both, despite the presence of hemiparesis, providing new evidence that changes in motor patterns after stroke may occur to compensate for stroke-related motor impairment.

  5. Fuel assembly gripping device using self-locking mechanism

    International Nuclear Information System (INIS)

    Lee, G. M.; Choi, S.; Kim, K. S.; Kim, T. W.; Jeong, K. H.; Park, K. B.; Chang, M. H.

    1999-07-01

    This report presents an actuating principles and structure for two kind of the fuel assembly gripping devices (Gripper-A, B) developed for SMART. The main components of these grippers are push bundle, rotation bundle, upper guide tube and chuck assembly. The rope attached to winch system on moving cask hangs gripper's push bundle. Due to a down-and-up operation of winch system, the push bundle pushes crown teeth shaped rotation bundle and then it is pushed down and rotated counter clockwise. The push-and-pull sequential operation of push bundle makes the rotation bundle is pushed, rotated and returned, moreover it makes the chuck assembly is expanded or shrunk. The expansion and shrinkage motion of chuck assembly makes the gripper latch and release the fuel assembly. Gripper-A suits for the handling of the fuel assembly with square shaped latching hole. Otherwise Gripper-B suits for a circular shaped latching hole. (author). 5 refs., 20 figs

  6. Deficits of anticipatory grip force control after damage to peripheral and central sensorimotor systems.

    Science.gov (United States)

    Hermsdörfer, Joachim; Hagl, Elke; Nowak, Dennis A

    2004-11-01

    Healthy subjects adjust their grip force economically to the weight of a hand-held object. In addition, inertial loads, which arise from arm movements with the grasped object, are anticipated by parallel grip force modulations. Internal forward models have been proposed to predict the consequences of voluntary movements. Anesthesia of the fingers impairs grip force economy but the feedforward character of the grip force/load coupling is preserved. To further analyze the role of sensory input for internal forward models and to characterize the consequences of central nervous system damage for anticipatory grip force control, we measured grip force behavior in neurological patients. We tested a group of stroke patients with varying degrees of impaired fine motor control and sensory loss, a single patient with complete and permanent differentation from all tactile and proprioceptive input, and a group of patients with amyotrophic lateral sclerosis (ALS) that exclusively impairs the motor system without affecting sensory modalities. Increased grip forces were a common finding in all patients. Sensory deficits were a strong but not the only predictor of impaired grip force economy. The feedforward mode of grip force control was typically preserved in the stroke patients despite their central sensory deficits, but was severely disturbed in the patient with peripheral sensory deafferentation and in a minority of stroke patients. Moderate deficits of feedforward control were also obvious in ALS patients. Thus, the function of the internal forward model and the precision of grip force production may depend on a complex anatomical and functional network of sensory and motor structures and their interaction in time and space.

  7. Comparative study of maximum isometric grip strength in different sports

    Directory of Open Access Journals (Sweden)

    Noé Gomes Borges Junior

    2009-01-01

    Full Text Available http://dx.doi.org/10.5007/1980-0037.2009v11n3p292   The objective of this study was to compare maximum isometric grip strength (Fmaxbetween different sports and between the dominant (FmaxD and non-dominant (FmaxND hand. Twenty-nine male aikido (AI, jiujitsu (JJ, judo (JU and rowing (RO athletes and 21non-athletes (NA participated in the study. The hand strength test consisted of maintainingmaximum isometric grip strength for 10 seconds using a hand dynamometer. The position of the subjects was that suggested by the American Society of Hand Therapy. Factorial 2X5 ANOVA with Bonferroni correction, followed by a paired t test and Tukey test, was used for statistical analysis. The highest Fmax values were observed for the JJ group when using the dominant hand,followed by the JU, RO, AI and NA groups. Variation in Fmax could be attributed to handdominance (30.9%, sports modality (39.9% and the interaction between hand dominance andsport (21.3%. The present results demonstrated significant differences in Fmax between the JJ and AI groups and between the JJ and NA groups for both the dominant and non-dominant hand. Significant differences in Fmax between the dominant and non-dominant hand were only observed in the AI and NA groups. The results indicate that Fmax can be used for comparisonbetween different sports modalities, and to identify differences between the dominant and nondominanthand. Studies involving a larger number of subjects will permit the identification of differences between other modalities.

  8. Hand Grip Strength: age and gender stratified normative data in a population-based study

    Directory of Open Access Journals (Sweden)

    Taylor Anne W

    2011-04-01

    Full Text Available Abstract Background The North West Adelaide Health Study is a representative longitudinal cohort study of people originally aged 18 years and over. The aim of this study was to describe normative data for hand grip strength in a community-based Australian population. Secondary aims were to investigate the relationship between body mass index (BMI and hand grip strength, and to compare Australian data with international hand grip strength norms. Methods The sample was randomly selected and recruited by telephone interview. Overall, 3 206 (81% of those recruited participants returned to the clinic during the second stage (2004-2006 which specifically focused on the collection of information relating to musculoskeletal conditions. Results Following the exclusion of 435 participants who had hand pain and/or arthritis, 1366 men and 1312 women participants provided hand grip strength measurement. The study population was relatively young, with 41.5% under 40 years; and their mean BMI was 28.1 kg/m2 (SD 5.5. Higher hand grip strength was weakly related to higher BMI in adults under the age of 30 and over the age of 70, but inversely related to higher BMI between these ages. Australian norms from this sample had amongst the lowest of the hand grip strength of the internationally published norms, except those from underweight populations. Conclusions This population demonstrated higher BMI and lower grip strength in younger participants than much of the international published, population data. A complete exploration of the relationship between BMI and hand grip strength was not fully explored as there were very few participants with BMI in the underweight range. The age and gender grip strength values are lower in younger adults than those reported in international literature.

  9. Stable isotope ratio mass spectrometry and physical comparison for the forensic examination of grip-seal plastic bags.

    Science.gov (United States)

    Taylor, Erica; Carter, James F; Hill, Jenny C; Morton, Carolyn; Daeid, Niamh Nic; Sleeman, Richard

    2008-05-20

    Plastic bags are frequently used to package drugs, explosives and other contraband. There exists, therefore, a requirement in forensic casework to compare bags found at different locations. This is currently achieved almost exclusively by the use of physical comparisons such as birefringence patterns. This paper discusses some of the advantages and shortcomings of this approach, and presents stable isotope ratio mass spectrometry (IRMS) as a supplementary tool for effecting comparisons of this nature. Carbon and hydrogen isotopic data are presented for sixteen grip-seal plastic bags from a wide range of sources, in order to demonstrate the range of values which is likely to be encountered. Both isotopic and physical comparison (specifically birefringence) techniques are then applied to the analysis of rolls of bags from different manufacturing lots from a leading manufacturer. Both approaches are able to associate bags from a common production batch. IRMS can be applied to small fragments which are not amenable to physical comparisons, and is able to discriminate bags which could be confused using birefringence patterns alone. Similarly, in certain cases birefringence patterns discriminate bags with similar isotopic compositions. The two approaches are therefore complementary. When more than one isotopically distinct region exists within a bag (e.g. the grip-seal is distinct from the body) the ability to discriminate and associate bags is greatly increased.

  10. Grip Strength and Its Relationship to Police Recruit Task Performance and Injury Risk: A Retrospective Cohort Study.

    Science.gov (United States)

    Orr, Robin; Pope, Rodney; Stierli, Michael; Hinton, Benjamin

    2017-08-21

    Suitable grip strength is a police occupational requirement. The aim of this study was to investigate the association between grip strength, task performance and injury risk in a police population. Retrospective data of police recruits (n = 169) who had undergone basic recruit training were provided, including handgrip strength results, occupational task performance measures (consisting of police task simulations [SIM], tactical options [TACOPS] and marksmanship assessments) and injury records. Left hand grip strength (41.91 ± 8.29 kg) measures showed a stronger correlation than right hand grip strength (42.15 ± 8.53 kg) with all outcome measures. Recruits whose grip strength scores were lower were significantly more susceptible to failing the TACOPS occupational task assessment than those with greater grip strength scores, with significant ( p ≤ 0.003) weak to moderate, positive correlations found between grip strength and TACOPS performance. A significant ( p performance, with those performing better in marksmanship having higher grip strength. Left hand grip strength was significantly associated with injury risk ( r = -0.181, p = 0.018) but right hand grip strength was not. A positive association exists between handgrip strength and police recruit task performance (notably TACOPS and marksmanship) with recruits who scored poorly on grip strength being at greatest risk of occupational assessment task failure.

  11. Fuel assembly gripping device using self-locking mechanism

    Energy Technology Data Exchange (ETDEWEB)

    Lee, G. M.; Choi, S.; Kim, K. S.; Kim, T. W.; Jeong, K. H.; Park, K. B.; Chang, M. H

    1999-07-01

    This report presents an actuating principles and structure for two kind of the fuel assembly gripping devices (Gripper-A, B) developed for SMART. The main components of these grippers are push bundle, rotation bundle, upper guide tube and chuck assembly. The rope attached to winch system on moving cask hangs gripper's push bundle. Due to a down-and-up operation of winch system, the push bundle pushes crown teeth shaped rotation bundle and then it is pushed down and rotated counter clockwise. The push-and-pull sequential operation of push bundle makes the rotation bundle is pushed, rotated and returned, moreover it makes the chuck assembly is expanded or shrunk. The expansion and shrinkage motion of chuck assembly makes the gripper latch and release the fuel assembly. Gripper-A suits for the handling of the fuel assembly with square shaped latching hole. Otherwise Gripper-B suits for a circular shaped latching hole. (author). 5 refs., 20 figs.

  12. Effect of Putting Grip on Eye and Head Movements During the Golf Putting Stroke

    Directory of Open Access Journals (Sweden)

    George K. Hung

    2003-01-01

    Full Text Available The objective of this article is to determine the effect of three different putting grips (conventional, cross-hand, and one-handed on variations in eye and head movements during the putting stroke. Seven volunteer novice players, ranging in age from 21 to 22 years, participated in the study. During each experimental session, the subject stood on a specially designed platform covered with artificial turf and putted golf balls towards a standard golf hole. The three different types of grips were tested at two distances: 3 and 9 ft. For each condition, 20 putts were attempted. For each putt, data were recorded over a 3-s interval at a sampling rate of 100 Hz. Eye movements were recorded using a helmet-mounted eye movement monitor. Head rotation about an imaginary axis through the top of the head and its center-of-rotation was measured by means of a potentiometer mounted on a fixed frame and coupled to the helmet. Putter-head motion was measured using a linear array of infrared phototransistors embedded in the platform. The standard deviation (STD, relative to the initial level was calculated for eye and head movements over the duration of the putt (i.e., from the beginning of the backstroke, through the forward stroke, to impact. The averaged STD for the attempted putts was calculated for each subject. Then, the averaged STDs and other data for the seven subjects were statistically compared across the three grip conditions. The STD of eye movements were greater (p < 0.1 for conventional than cross-hand (9 ft and one-handed (3 and 9 ft grips. Also, the STD of head movements were greater (p < 0.1; 3 ft for conventional than cross-hand and one-handed grips. Vestibulo-ocular responses associated with head rotations could be observed in many 9 ft and some 3 ft putts. The duration of the putt was significantly longer (p < 0.05; 3 and 9 ft for the one-handed than conventional and cross-hand grips. Finally, performance, or percentage putts made, was

  13. Grip strength in mice with joint inflammation: A rheumatology function test sensitive to pain and analgesia.

    Science.gov (United States)

    Montilla-García, Ángeles; Tejada, Miguel Á; Perazzoli, Gloria; Entrena, José M; Portillo-Salido, Enrique; Fernández-Segura, Eduardo; Cañizares, Francisco J; Cobos, Enrique J

    2017-10-01

    Grip strength deficit is a measure of pain-induced functional disability in rheumatic disease. We tested whether this parameter and tactile allodynia, the standard pain measure in preclinical studies, show parallels in their response to analgesics and basic mechanisms. Mice with periarticular injections of complete Freund's adjuvant (CFA) in the ankles showed periarticular immune infiltration and synovial membrane alterations, together with pronounced grip strength deficits and tactile allodynia measured with von Frey hairs. However, inflammation-induced tactile allodynia lasted longer than grip strength alterations, and therefore did not drive the functional deficits. Oral administration of the opioid drugs oxycodone (1-8 mg/kg) and tramadol (10-80 mg/kg) induced a better recovery of grip strength than acetaminophen (40-320 mg/kg) or the nonsteroidal antiinflammatory drugs ibuprofen (10-80 mg/kg) or celecoxib (40-160 mg/kg); these results are consistent with their analgesic efficacy in humans. Functional impairment was generally a more sensitive indicator of drug-induced analgesia than tactile allodynia, as drug doses that attenuated grip strength deficits showed little or no effect on von Frey thresholds. Finally, ruthenium red (a nonselective TRP antagonist) or the in vivo ablation of TRPV1-expressing neurons with resiniferatoxin abolished tactile allodynia without altering grip strength deficits, indicating that the neurobiology of tactile allodynia and grip strength deficits differ. In conclusion, grip strength deficits are due to a distinct type of pain that reflects an important aspect of the human pain experience, and therefore merits further exploration in preclinical studies to improve the translation of new analgesics from bench to bedside. Copyright © 2017 The Authors. Published by Elsevier Ltd.. All rights reserved.

  14. Adaptive grip force is modulated by subthalamic beta activity in Parkinson's disease patients

    Directory of Open Access Journals (Sweden)

    Lukas L. Imbach

    2015-01-01

    Conclusion: The time-locked suppression of beta oscillatory activity in the STN is in line with previous reports of beta ERD prior to voluntary movements. Our results show that the STN is involved in anticipatory grip force control in PD patients. The difference in the phasic beta ERD between the two tasks and the reduction of cortico-subthalamic synchronization suggests that qualitatively different neuronal network states are involved in different grip force control tasks.

  15. Predicting hand function in older adults: evaluations of grip strength, arm curl strength, and manual dexterity.

    Science.gov (United States)

    Liu, Chiung-Ju; Marie, Deana; Fredrick, Aaron; Bertram, Jessica; Utley, Kristen; Fess, Elaine Ewing

    2017-08-01

    Hand function is critical for independence in activities of daily living for older adults. The purpose of this study was to examine how grip strength, arm curl strength, and manual dexterous coordination contributed to time-based versus self-report assessment of hand function in community-dwelling older adults. Adults aged ≥60 years without low vision or neurological disorders were recruited. Purdue Pegboard Test, Jamar hand dynamometer, 30-second arm curl test, Jebsen-Taylor Hand Function Test, and the Late-Life Function and Disability Instrument were administered to assess manual dexterous coordination, grip strength, arm curl strength, time-based hand function, and self-report of hand function, respectively. Eighty-four adults (mean age = 72 years) completed the study. Hierarchical multiple regressions show that older adults with better arm curl strength (β = -.25, p function test. In comparison, older adults with better grip strength (β = .40, p function. The relationship between grip strength and hand function may be test-specific. Grip strength becomes a significant factor when the test requires grip strength to successfully complete the test tasks. Arm curl strength independently contributed to hand function in both time-based and self-report assessments, indicating that strength of extrinsic muscles of the hand are essential for hand function.

  16. The effects of grip width on sticking region in bench press.

    Science.gov (United States)

    Gomo, Olav; Van Den Tillaar, Roland

    2016-01-01

    The aim of this study was to examine the occurrence of the sticking region by examining how three different grip widths affect the sticking region in powerlifters' bench press performance. It was hypothesised that the sticking region would occur at the same joint angle of the elbow and shoulder independent of grip width, indicating a poor mechanical region for vertical force production at these joint angles. Twelve male experienced powerlifters (age 27.7 ± 8.8 years, mass 91.9 ± 15.4 kg) were tested in one repetition maximum (1-RM) bench press with a narrow, medium and wide grip. Joint kinematics, timing, bar position and velocity were measured with a 3D motion capture system. All participants showed a clear sticking region with all three grip widths, but this sticking region was not found to occur at the same joint angles in all three grip widths, thereby rejecting the hypothesis that the sticking region would occur at the same joint angle of the elbow and shoulder independent of grip width. It is suggested that, due to the differences in moment arm of the barbell about the elbow joint in the sticking region, there still might be a poor mechanical region for total force production that is joint angle-specific.

  17. PICK1 interacts with ABP/GRIP to regulate AMPA receptor trafficking.

    Science.gov (United States)

    Lu, Wei; Ziff, Edward B

    2005-08-04

    PICK1 and ABP/GRIP bind to the AMPA receptor (AMPAR) GluR2 subunit C terminus. Transfer of the receptor from ABP/GRIP to PICK1, facilitated by GluR2 S880 phosphorylation, may initiate receptor trafficking. Here we report protein interactions that regulate these steps. The PICK1 BAR domain interacts intermolecularly with the ABP/GRIP linker II region and intramolecularly with the PICK1 PDZ domain. Binding of PKCalpha or GluR2 to the PICK1 PDZ domain disrupts the intramolecular interaction and facilitates the PICK1 BAR domain association with ABP/GRIP. Interference with the PICK1-ABP/GRIP interaction impairs S880 phosphorylation of GluR2 by PKC and decreases the constitutive surface expression of GluR2, the NMDA-induced endocytosis of GluR2, and recycling of internalized GluR2. We suggest that the PICK1 interaction with ABP/GRIP is a critical step in controlling GluR2 trafficking.

  18. Differences in grip force control between young and late middle-aged adults.

    Science.gov (United States)

    Zheng, Lianrong; Li, Kunyang; Wang, Qian; Chen, Wenhui; Song, Rong; Liu, Guanzheng

    2017-09-01

    Grip force control is a crucial function for human to guarantee the quality of life. To examine the effects of age on grip force control, 10 young adults and 11 late middle-aged adults participated in visually guided tracking tasks using different target force levels (25, 50, and 75% of the subject's maximal grip force). Multiple measures were used to evaluate the tracking performance during force rising phase and force maintenance phase. The measurements include the rise time, fuzzy entropy, mean force percentage, coefficient of variation, and target deviation ratio. The results show that the maximal grip force was significantly lower in the late middle-aged adults than in the young adults. The time of rising phase was systematically longer among late middle-aged adults. The fuzzy entropy is a useful indicator for quantitating the force variability of the grip force signal at higher force levels. These results suggest that the late middle-aged adults applied a compensatory strategy that allow allows for sufficient time to reach the required grip force and reduce the impact of the early and subtle degenerative changes in hand motor function.

  19. Hold, grasp, clutch or grab: consumer grip choices during food container opening.

    Science.gov (United States)

    Rowson, J; Yoxall, A

    2011-07-01

    Society is ageing and sadly that ageing leads to a host of issues, not least a society in which the majority are likely to have some loss of strength and dexterity. This can lead to complications in undertaking everyday tasks such as using transport, bathing or even handling and opening food. Packaging has to provide a multitude of services; to protect and preserve the product, to provide information to the consumer and not least to allow access to the contents. This access to packaging--or 'openability'--has become a significant issue for designers and manufacturers with the change in demographics as described above. Understanding the choices consumers make in how they manipulate packaging can help designers produce packaging that is more able to meet the requirements of modern society. Studies previously undertaken by the authors showed that consumers did use different grips when opening packaging and that certain grips were theoretically more comfortable and stronger than others. This paper outlines a further study whereby consumers were asked to apply the most common grips to a specially designed torque measuring device. Details were taken about the consumers: age, gender, occupation, hand size, plus their preferred grip choice for packaging of this type. The study showed that typically women chose a grip that maximised their opportunity of opening the closure and that this grip choice was more limited than that available for men. This has implications for inclusive design of many everyday products. Copyright © 2010 Elsevier Ltd and The Ergonomics Society. All rights reserved.

  20. Longitudinal assessment of grip strength using bulb dynamometer in Duchenne Muscular Dystrophy

    Directory of Open Access Journals (Sweden)

    Tatiana M. Pizzato

    2014-07-01

    Full Text Available BACKGROUND: Grip strength is used to infer functional status in several pathological conditions, and the hand dynamometer has been used to estimate performance in other areas. However, this relationship is controversial in neuromuscular diseases and studies with the bulb dynamometer comparing healthy children and children with Duchenne Muscular Dystrophy (DMD are limited. OBJECTIVE: The evolution of grip strength and the magnitude of weakness were examined in boys with DMD compared to healthy boys. The functional data of the DMD boys were correlated with grip strength. METHOD: Grip strength was recorded in 18 ambulant boys with DMD (Duchenne Group, DG aged 4 to 13 years (mean 7.4±2.1 and 150 healthy volunteers (Control Group, CG age-matched using a bulb dynamometer (North Coast- NC70154. The follow-up of the DG was 6 to 33 months (3-12 sessions, and functional performance was verified using the Vignos scale. RESULTS: There was no difference between grip strength obtained by the dominant and non-dominant side for both groups. Grip strength increased in the CG with chronological age while the DG remained stable or decreased. The comparison between groups showed significant difference in grip strength, with CG values higher than DG values (confidence interval of 95%. In summary, there was an increment in the differences between the groups with increasing age. Participants with 24 months or more of follow-up showed a progression of weakness as well as maintained Vignos scores. CONCLUSIONS: The amplitude of weakness increased with age in the DG. The bulb dynamometer detected the progression of muscular weakness. Functional performance remained virtually unchanged in spite of the increase in weakness.

  1. Inertial torque during reaching directly impacts grip-force adaptation to weightless objects.

    Science.gov (United States)

    Giard, T; Crevecoeur, F; McIntyre, J; Thonnard, J-L; Lefèvre, P

    2015-11-01

    A hallmark of movement control expressed by healthy humans is the ability to gradually improve motor performance through learning. In the context of object manipulation, previous work has shown that the presence of a torque load has a direct impact on grip-force control, characterized by a significantly slower grip-force adjustment across lifting movements. The origin of this slower adaptation rate remains unclear. On the one hand, information about tangential constraints during stationary holding may be difficult to extract in the presence of a torque. On the other hand, inertial torque experienced during movement may also potentially disrupt the grip-force adjustments, as the dynamical constraints clearly differ from the situation when no torque load is present. To address the influence of inertial torque loads, we instructed healthy adults to perform visually guided reaching movements in weightlessness while holding an unbalanced object relative to the grip axis. Weightlessness offered the possibility to remove gravitational constraints and isolate the effect of movement-related feedback on grip force adjustments. Grip-force adaptation rates were compared with a control group who manipulated a balanced object without any torque load and also in weightlessness. Our results clearly show that grip-force adaptation in the presence of a torque load is significantly slower, which suggests that the presence of torque loads experienced during movement may alter our internal estimates of how much force is required to hold an unbalanced object stable. This observation may explain why grasping objects around the expected location of the center of mass is such an important component of planning and control of manipulation tasks.

  2. Studying hand grip strength development among students who have taken tennis and massage courses

    Directory of Open Access Journals (Sweden)

    Erzeybek Mustafa Said

    2017-01-01

    Full Text Available In this study, the finger and hand force developments of the students who have taken selective/applied Tennis and Massage courses at the University have been examined. From the students of the Department of Physical Education and Sport, 19 healthy females and 73 healthy males (age = 21.25 ± 1.55 years (average ± SD who have taken selective Tennis courses;51 healthy males (age = 22.00 ± 1.04 years (average ± SD who have taken Massage courses; and as the control group,16 healthy womenand50 healthy males(age = 21.72 ± 1.47 years (average ± SD have been participated to the study. The age, length, body weight, grip strength of both hands as well as the finger grip strength of the subjects have been recorded. The course schedule has been set as once a week four hours practice for both tennis and massage. Two weeks of the education and training program that takes twelve weeks in total were assigned for theoretical classes. The remaining period of ten weeks was for practice classes and the measurements were performed before and after this ten weeks period. The hand grip strength measurement has been carried out with a Takkei branded hand dynamometer whereas for the measurement of the finger grip strength, a Baseline branded pinch meter has been used. For both the pre-test and final test of the finger grip and hand grip strength measurements, the paired sample t test has been used in terms of in-group comparisons, whereas for the inter-group comparisons, one-way ANOVA has been used. For the significant F values, post hoc Tukey test has been used. The right hand and the left hand grip values of both test groups as well as the values of the control group have been significantly increased between the pre-test and final test. Particularly, preferring the exercises that improve the hand and finger grip strengths would enable a better racket handle grip as well as an improved shot efficiency for tennis. This would also enable masseurs/masseuses to apply

  3. Association between grip strength and hand and knee radiographic osteoarthritis in Korean adults: Data from the Dong-gu study.

    Directory of Open Access Journals (Sweden)

    Lihui Wen

    Full Text Available We assessed whether grip strength was related to various types of radiographic damage in Korean adults with osteoarthritis (OA.Data from 2,251 subjects enrolled in the Dong-gu study, who had no hand joint pain, were analyzed to investigate the relationship between grip strength and OA. Hand grip strength was measured using a hand-held dynamometer, and radiographs of the hand and knee were scored according to a semi-quantitative grading system. Multiple linear regressions were used to explore associations between grip strength and radiographic features of OA.Grip strength in men and women was negatively related to hand (both p < 0.001 and knee (men, p < 0.001; women, p = 0.010 OA after adjusting for confounders. Hand (men, p < 0.001; women, p = 0.001 and knee (both p < 0.001 joint space narrowing (JSN showed the strongest associations with low grip strength, regardless of gender. Moreover, the severity of hand osteophytes in women (p = 0.001, and subchondral cysts (men, p < 0.001 was correlated with low grip strength in both genders.Among subjects without hand joint pain, low grip strength was associated significantly with hand and knee radiographic OA, regardless of gender. Among all types of OA radiographic damage, low grip strength showed the strongest association with JSN.

  4. The brain adjusts grip forces differently according to gravity and inertia: a parabolic flight experiment

    Directory of Open Access Journals (Sweden)

    Olivier eWhite

    2015-02-01

    Full Text Available In everyday life, one of the most frequent activities involves accelerating and decelerating an object held in precision grip. In many contexts, humans scale and synchronize their grip force, normal to the finger/object contact, in anticipation of the expected tangential load force, resulting from the combination of the gravitational and the inertial forces. In many contexts, grip force and load force are linearly coupled. A few studies have examined how we adjust the parameters - gain and offset - of this linear relationship. However, the question remains open as to how the brain adjusts grip force regardless of whether load force is generated by different combinations of weight and inertia. Here, we designed conditions to generate equivalent magnitudes of load force by independently varying mass and movement frequency. In a control experiment, we directly manipulated gravity in parabolic flights, while other factors remained constant. We show with a simple computational approach that, to adjust grip force, the brain is sensitive to how load forces are produced at the fingertips. This provides clear evidence that the analysis of the origin of load force is performed centrally, and not only at the periphery.

  5. Grip type and task goal modify reach-to-grasp performance in post-stroke hemiparesis

    Science.gov (United States)

    Schaefer, Sydney Y.; DeJong, Stacey L.; Cherry, Kendra M.; Lang, Catherine E.

    2011-01-01

    This study investigated whether grip type and/or task goal influenced reaching and grasping performance in post-stroke hemiparesis. Sixteen adults with post-stroke hemiparesis and twelve healthy adults reached to and grasped a cylindrical object using one of two grip types (3-finger or palmar) to achieve one of two task goals (hold or lift). Performance of the stroke group was characteristic of hemiparetic limb movement during reach-to-grasp, with more curved handpaths and slower velocities compared to the control group. These effects were present regardless of grip type or task goal. Other measures of reaching (reach time and reach velocity at object contact) and grasping (peak thumb-index finger aperture during the reach and peak grip force during the grasp) were differentially affected by grip type, task goal, or both, despite the presence of hemiparesis, providing new evidence that changes in motor patterns after stroke may occur to compensate for stroke-related motor impairment. PMID:22357103

  6. Probabilistic information on object weight shapes force dynamics in a grip-lift task.

    Science.gov (United States)

    Trampenau, Leif; Kuhtz-Buschbeck, Johann P; van Eimeren, Thilo

    2015-06-01

    Advance information, such as object weight, size and texture, modifies predictive scaling of grip forces in a grip-lift task. Here, we examined the influence of probabilistic advance information about object weight. Fifteen healthy volunteers repeatedly grasped and lifted an object equipped with a force transducer between their thumb and index finger. Three clearly distinguishable object weights were used. Prior to each lift, the probabilities for the three object weights were given by a visual cue. We examined the effect of probabilistic pre-cues on grip and lift force dynamics. We expected predictive scaling of grip force parameters to follow predicted values calculated according to probabilistic contingencies of the cues. We observed that probabilistic cues systematically influenced peak grip and load force rates, as an index of predictive motor scaling. However, the effects of probabilistic cues on force rates were nonlinear, and anticipatory adaptations of the motor output generally seemed to overestimate high probabilities and underestimate low probabilities. These findings support the suggestion that anticipatory adaptations and force scaling of the motor system can integrate probabilistic information. However, probabilistic information seems to influence motor programs in a nonlinear fashion.

  7. Attentional Focus and Grip Width Influences on Bench Press Resistance Training.

    Science.gov (United States)

    Calatayud, Joaquin; Vinstrup, Jonas; Jakobsen, Markus D; Sundstrup, Emil; Colado, JuanCarlos; Andersen, Lars L

    2018-04-01

    This study evaluated the influence of different attentional foci for varied grip widths in the bench press. Eighteen resistance-trained men were familiarized with the procedure and performed a one-repetition maximum (1RM) test during Session 1. In Session 2, they used three different standardized grip widths (100%, 150%, and 200% of biacromial width distance) in random order at 50% of 1RM while also engaged in three different attention focus conditions (external focus on the bench press, internal focus on pectoralis major muscles, and internal focus on triceps brachii muscles). Surface electromyography (EMG) signals were recorded from the triceps brachii and pectoralis major, and peak EMG of the filtered signals were normalized to maximum EMG of each muscle. Both grip width and focus influenced the muscle activity level, but there were no significant interactions between these variables. Exploratory analyses suggested that an internal focus may slightly (4%-6%) increase pectoralis major activity at wider grip widths and triceps brachii activity at narrower grip widths, but this should be confirmed or rejected in a study with a larger sample size or through a meta-analysis of research to date.

  8. Identification of dynapenia in older adults through the use of grip strength t-scores.

    Science.gov (United States)

    Bohannon, Richard W; Magasi, Susan

    2015-01-01

    The aim of this study was to generate reference values and t-scores (1.0-2.5 standard deviations below average) for grip strength for healthy young adults and to examine the utility of t-scores from this group for the identification of dynapenia in older adults. Our investigation was a population-based, general community secondary analysis of cross-sectional grip strength data utilizing the NIH Toolbox Assessment norming sample. Participants consisted of community-dwelling adults, with age ranges of 20-40 years (n = 558) and 60-85 years (n = 390). The main outcome measure was grip strength using a Jamar plus dynamometer. Maximum grip strengths were consistent over the 20-40-year age group [men 108.0 (SD 22.6) pounds, women 65.8 (SD 14.6) pounds]. Comparison of older group grip strengths to those of the younger reference group revealed (depending on age strata) that 46.2-87.1% of older men and 50.0-82.4% of older women could be designated as dynapenic on the basis of t-scores. The use of reference value t-scores from younger adults is a promising method for determining dynapenia in older adults. © 2014 Wiley Periodicals, Inc.

  9. Getting a grip: different actions and visual guidance of the thumb and finger in precision grasping.

    Science.gov (United States)

    Melmoth, Dean R; Grant, Simon

    2012-10-01

    We manipulated the visual information available for grasping to examine what is visually guided when subjects get a precision grip on a common class of object (upright cylinders). In Experiment 1, objects (2 sizes) were placed at different eccentricities to vary the relative proximity to the participant's (n = 6) body of their thumb and finger contact positions in the final grip orientations, with vision available throughout or only for movement programming. Thumb trajectories were straighter and less variable than finger paths, and the thumb normally made initial contact with the objects at a relatively invariant landing site, but consistent thumb first-contacts were disrupted without visual guidance. Finger deviations were more affected by the object's properties and increased when vision was unavailable after movement onset. In Experiment 2, participants (n = 12) grasped 'glow-in-the-dark' objects wearing different luminous gloves in which the whole hand was visible or the thumb or the index finger was selectively occluded. Grip closure times were prolonged and thumb first-contacts disrupted when subjects could not see their thumb, whereas occluding the finger resulted in wider grips at contact because this digit remained distant from the object. Results were together consistent with visual feedback guiding the thumb in the period just prior to contacting the object, with the finger more involved in opening the grip and avoiding collision with the opposite contact surface. As people can overtly fixate only one object contact point at a time, we suggest that selecting one digit for online guidance represents an optimal strategy for initial grip placement. Other grasping tasks, in which the finger appears to be used for this purpose, are discussed.

  10. The effect of ergonomic laparoscopic tool handle design on performance and efficiency.

    Science.gov (United States)

    Tung, Kryztopher D; Shorti, Rami M; Downey, Earl C; Bloswick, Donald S; Merryweather, Andrew S

    2015-09-01

    Many factors can affect a surgeon's performance in the operating room; these may include surgeon comfort, ergonomics of tool handle design, and fatigue. A laparoscopic tool handle designed with ergonomic considerations (pistol grip) was tested against a current market tool with a traditional pinch grip handle. The goal of this study is to quantify the impact ergonomic design considerations which have on surgeon performance. We hypothesized that there will be measurable differences between the efficiency while performing FLS surgical trainer tasks when using both tool handle designs in three categories: time to completion, technical skill, and subjective user ratings. The pistol grip incorporates an ergonomic interface intended to reduce contact stress points on the hand and fingers, promote a more neutral operating wrist posture, and reduce hand tremor and fatigue. The traditional pinch grip is a laparoscopic tool developed by Stryker Inc. widely used during minimal invasive surgery. Twenty-three (13 M, 10 F) participants with no existing upper extremity musculoskeletal disorders or experience performing laparoscopic procedures were selected to perform in this study. During a training session prior to testing, participants performed practice trials in a SAGES FLS trainer with both tools. During data collection, participants performed three evaluation tasks using both handle designs (order was randomized, and each trial completed three times). The tasks consisted of FLS peg transfer, cutting, and suturing tasks. Feedback from test participants indicated that they significantly preferred the ergonomic pistol grip in every category (p < 0.05); most notably, participants experienced greater degrees of discomfort in their hands after using the pinch grip tool. Furthermore, participants completed cutting and peg transfer tasks in a shorter time duration (p < 0.05) with the pistol grip than with the pinch grip design; there was no significant difference between completion

  11. Relationship between lung function and grip strength in older hospitalized patients: a pilot study

    Directory of Open Access Journals (Sweden)

    Holmes SJ

    2017-04-01

    Full Text Available Sarah J Holmes,1 Stephen C Allen,2,3 Helen C Roberts4,5 1Medicine and Elderly Care, Hampshire Hospitals NHS Foundation Trust, Winchester, 2Medicine and Geriatrics, The Royal Bournemouth Hospital and Christchurch Hospitals NHS Foundation Trust, Bournemouth, 3Centre of Postgraduate Medical Research and Education, Bournemouth University, Poole, 4Academic Geriatric Medicine, University of Southampton, 5University Hospital Southampton NHS Foundation Trust, Southampton, UK Objective: Older people with reduced respiratory muscle strength may be misclassified as having COPD on the basis of spirometric results. We aimed to evaluate the relationship between lung function and grip strength in older hospitalized patients without known airways disease.Methods: Patients in acute medical wards were recruited who were aged ≥70 years; no history, symptoms, or signs of respiratory disease; Mini Mental State Examination ≥24; willing and able to consent to participate; and able to perform hand grip and forced spirometry. Data including lung function (forced expiratory volume in 1 second [FEV1], forced vital capacity [FVC], FEV1/FVC, peak expiratory flow rate [PEFR], and slow vital capacity [SVC], grip strength, age, weight, and height were recorded. Data were analyzed using descriptive statistics and linear regression unadjusted and adjusted (for age, height, and weight.Results: A total of 50 patients (20 men were recruited. Stronger grip strength in men was significantly associated with greater FEV1, but this was attenuated by adjustment for age, height, and weight. Significant positive associations were found in women between grip strength and both PEFR and SVC, both of which remained robust to adjustment.Conclusion: The association between grip strength and PEFR and SVC may reflect stronger patients generating higher intrathoracic pressure at the start of spirometry and pushing harder against thoracic cage recoil at end-expiration. Conversely, patients with

  12. Development of Hand Grip Assistive Device Control System for Old People through Electromyography (EMG) Signal Acquisitions

    OpenAIRE

    Khamis Herman; Mohamaddan Shahrol; Komeda Takashi; Alias Aidil Azli; Tanjong Shirley Jonathan; Julai Norhuzaimin; Hashim Nurul ‘Izzati

    2017-01-01

    The hand grip assistive device is a glove to assist old people who suffer from hand weakness in their daily life activities. The device earlier control system only use simple on and off switch. This required old people to use both hand to activate the device. The new control system of the hand grip assistive device was developed to allow single hand operation for old people. New control system take advantages of electromyography (EMG) and flex sensor which was implemented to the device. It wa...

  13. Direct observation of salts as micro-inclusions in the Greenland GRIP ice core

    DEFF Research Database (Denmark)

    Dahl-Jensen, Dorthe; Sakurai, Toshimitsu; Iizuka, Yoshinori

    2009-01-01

    We provide the first direct evidence that a number of water-soluble compounds, in particular calcium sulfate (CaSO4·2H2O) and calcium carbonate (CaCO3), are present as solid, micron-sized inclusions within the Greenland GRIP ice core. The compounds are detected by two independent methods: micro...... distributions of the micro-inclusions. These results suggest that water-soluble aerosols in the GRIP ice core are dependable proxies for past atmospheric conditions. Udgivelsesdato: December...

  14. Large-scale GWAS identifies multiple loci for hand grip strength providing biological insights into muscular fitness

    NARCIS (Netherlands)

    Willems, Sara M.; Wright, D.J.; Day, Felix R.; Trajanoska, Katerina; Joshi, P.K.; Morris, John A.; Matteini, Amy M.; Garton, Fleur C.; Grarup, Niels; Oskolkov, Nikolay; Thalamuthu, Anbupalam; Mangino, Massimo; Liu, Jun; Demirkan, Ayse; Lek, Monkol; Xu, Liwen; Wang, Guan; Oldmeadow, Christopher; Gaulton, Kyle J.; Lotta, Luca A.; Miyamoto-Mikami, Eri; Rivas, Manuel A.; White, Tom; Loh, Po Ru; Aadahl, Mette; Amin, Najaf; Attia, John R.; Austin, Krista; Benyamin, Beben; Brage, Søren; Cheng, Yu Ching; Ciȩszczyk, Paweł; Derave, Wim; Eriksson, Karl Fredrik; Eynon, Nir; Linneberg, Allan; Lucia, Alejandro; Massidda, Myosotis; Mitchell, Braxton D.; Miyachi, Motohiko; Murakami, Haruka; Padmanabhan, Sandosh; Pandey, Ashutosh; Papadimitriou, Ioannis; Rajpal, Deepak K.; Sale, Craig; Schnurr, Theresia M.; Sessa, Francesco; Shrine, Nick; Tobin, Martin D.; Varley, Ian; Wain, Louise V.; Wray, Naomi R.; Lindgren, Cecilia M.; MacArthur, Daniel G.; Waterworth, Dawn M.; McCarthy, Mark I.; Pedersen, Oluf; Khaw, Kay Tee; Kiel, Douglas P.; Pitsiladis, Yannis; Fuku, Noriyuki; Franks, Paul W.; North, Kathryn N.; Duijn, Van C.M.; Mather, Karen A.; Hansen, Torben; Hansson, Ola; Spector, Tim D.; Murabito, Joanne M.; Richards, J.B.; Rivadeneira, Fernando; Langenberg, Claudia; Perry, John R.B.; Wareham, Nick J.; Scott, Robert A.; Oei, Ling; Zheng, Hou Feng; Forgetta, Vincenzo; Leong, Aaron; Ahmad, Omar S.; Laurin, Charles; Mokry, Lauren E.; Ross, Stephanie; Elks, Cathy E.; Bowden, Jack; Warrington, Nicole M.; Murray, Anna; Ruth, Katherine S.; Tsilidis, Konstantinos K.; Medina-Gómez, Carolina; Estrada, Karol; Bis, Joshua C.; Chasman, Daniel I.; Demissie, Serkalem; Enneman, Anke W.; Hsu, Yi Hsiang; Ingvarsson, Thorvaldur; Kähönen, Mika; Kammerer, Candace; Lacroix, Andrea Z.; Li, Guo; Liu, Ching Ti; Liu, Yongmei; Lorentzon, Mattias; Mägi, Reedik; Mihailov, Evelin; Milani, Lili; Moayyeri, Alireza; Nielson, Carrie M.; Sham, Pack Chung; Siggeirsdotir, Kristin; Sigurdsson, Gunnar; Stefansson, Kari; Trompet, Stella; Thorleifsson, Gudmar; Vandenput, Liesbeth; Velde, Van Der Nathalie; Viikari, Jorma; Xiao, Su Mei; Zhao, Jing Hua; Evans, Daniel S.; Cummings, Steven R.; Cauley, Jane; Duncan, Emma L.; Groot, De Lisette C.P.G.M.; Esko, Tonu; Gudnason, Vilmundar; Harris, Tamara B.; Jackson, Rebecca D.; Jukema, J.W.; Ikram, Arfan M.A.; Karasik, David; Kaptoge, Stephen; Kung, Annie Wai Chee; Lehtimäki, Terho; Lyytikäinen, Leo Pekka; Lips, Paul; Luben, Robert; Metspalu, Andres; Meurs, van Joyce B.; Minster, Ryan L.; Orwoll, Erick; Oei, Edwin; Psaty, Bruce M.; Raitakari, Olli T.; Ralston, Stuart W.; Ridker, Paul M.; Robbins, John A.; Smith, Albert V.; Styrkarsdottir, Unnur; Tranah, Gregory J.; Thorstensdottir, Unnur; Uitterlinden, Andre G.; Zmuda, Joseph; Zillikens, M.C.; Ntzani, Evangelia E.; Evangelou, Evangelos; Ioannidis, John P.A.; Evans, David M.; Ohlsson, Claes

    2017-01-01

    Hand grip strength is a widely used proxy of muscular fitness, a marker of frailty, and predictor of a range of morbidities and all-cause mortality. To investigate the genetic determinants of variation in grip strength, we perform a large-scale genetic discovery analysis in a combined sample of

  15. Grip strength and lower limb extension power in 19-72-year-old Danish men and women

    DEFF Research Database (Denmark)

    Aadahl, Mette; Beyer, Nina; Linneberg, Allan

    2011-01-01

    To assess muscular fitness by hand grip strength (HGS) and lower limb extension power (LEP) and to explore associations with age, leisure time physical activity (LTPA) and body composition.......To assess muscular fitness by hand grip strength (HGS) and lower limb extension power (LEP) and to explore associations with age, leisure time physical activity (LTPA) and body composition....

  16. Large-scale GWAS identifies multiple loci for hand grip strength providing biological insights into muscular fitness

    DEFF Research Database (Denmark)

    Willems, Sara M; Wright, Daniel J.; Day, Felix R

    2017-01-01

    with involvement of psychomotor impairment (PEX14, LRPPRC and KANSL1). Mendelian randomization analyses are consistent with a causal effect of higher genetically predicted grip strength on lower fracture risk. In conclusion, our findings provide new biological insight into the mechanistic underpinnings of grip...... strength and the causal role of muscular strength in age-related morbidities and mortality....

  17. Large-scale GWAS identifies multiple loci for hand grip strength providing biological insights into muscular fitness

    DEFF Research Database (Denmark)

    Willems, Sara M.; Wright, Daniel J.; Day, Felix R.

    2017-01-01

    Hand grip strength is a widely used proxy of muscular fitness, a marker of frailty, and predictor of a range of morbidities and all-cause mortality. To investigate the genetic determinants of variation in grip strength, we perform a large-scale genetic discovery analysis in a combined sample of 1...

  18. The development of a methodology to determine the relationship in grip size and pressure to racket head speed in a tennis forehand stroke

    DEFF Research Database (Denmark)

    Christensen, Jonas; Rasmussen, John; Halkon, Ben

    2016-01-01

    and kinematic contribution of the body segments in the upper trunk translational and angular velocities. Two Babolat Pure Storm GT rackets, with grip sizes 2 and 4 respectively, were used with Tekscan 9811E pressure sensors applied to the handles to examine pressure distribution during the stroke. Upper body...... kinematic data taken from the racket arm and trunk were obtained by means of a Vicon motion capture system. One elite male tennis player was recruited. Fifty topspin forehand strokes per grip at two nominal grip pressures were performed in a laboratory environment with balls being tossed towards the player...... joint and wrist joint in KCAV across grip conditions. Grip pressure for grip size 2 showed the same pattern across gripping conditions. From 50-75% of completion in forward swing, the pressure difference due to grip firmness decreased. This feasibility study managed to quantify the KCAV while performing...

  19. Fuel pin transfer tool

    International Nuclear Information System (INIS)

    Patenaude, R. S.

    1985-01-01

    A fuel pin transfer tool has a latching device of the collet type attached to a first member movable vertically through a long work stroke enabling a fuel pin in an under water assembly to be engaged and withdrawn therefrom or placed therein and released. The latching device has a collet provided with a plurality of resilient fingers having cam portions normally spaced apart to receive the upper end of a fuel pin between them and a second member, movable vertically through a short stroke relative to the first member is provided with cam portions engageable with those of the fingers and is yieldably and resiliently held in a raised position in which its cam portions engage those of the fingers and force the fingers into their pin-gripping positions. When a predetermined force is applied to the second member, it is so moved that its cam portions are disengaged from the cam portions of the fingers permitting the latter to move into their normal relationship in which a gripped pin is released or another pin received but with their pin-gripping relationship positively re-established and maintained once the force on the tubular member is lessened. Movement of the first member in either direction and movement of the second member into its raised position is attended by forces inadequate to affect the integrity of fuel pin cladding. That force is applied in the preferred embodiment, by a power operated actuator which is within the upper portion of a housing and, in the preferred embodiment, carried by the long stroke member but always in the upper housing portion which is of a material sufficiently translucent to enable the actuator to be observed throughout the work stroke and is sufficiently light in weight to prevent the tool from being top heavy

  20. Eyes, Grip and Gesture as Objective Indicators of Intentions and Attention

    DEFF Research Database (Denmark)

    Mortensen, Ditte Hvas

    This poster abstract presents the first part of a study concerning the use of information about gaze, grip and gesture to create non-command interaction. The experiment reported here seeks to establish the occurrence of patterns in nonverbal communication,  which may be used in an activity aware...

  1. Applying support vector regression analysis on grip force level-related corticomuscular coherence

    DEFF Research Database (Denmark)

    Rong, Yao; Han, Xixuan; Hao, Dongmei

    2014-01-01

    Voluntary motor performance is the result of cortical commands driving muscle actions. Corticomuscular coherence can be used to examine the functional coupling or communication between human brain and muscles. To investigate the effects of grip force level on corticomuscular coherence in an acces...

  2. Precision grip in congenital and acquired hemiparesis: similarities in impairments and implications for neurorehabilitation - review

    Directory of Open Access Journals (Sweden)

    Yannick eBleyenheuft

    2014-06-01

    Full Text Available Background: Patients with congenital and acquired hemiparesis incur long-term functional deficits, among which the loss of prehension that may impact their functional independence. Identifying, understanding and comparing the underlying mechanisms of prehension impairments represent an opportunity to better adapt neurorehabilitationObjective: The present review aims to provide a better understanding of precision grip deficits in congenital and acquired hemiparesis and to determine whether the severity and type of fine motor control impairments depend on whether or not the lesions are congenital or acquired in adulthood. Methods: Using combinations of the following key words: fingertip force, grip force, precision grip, cerebral palsy, stroke, pubmed and Scopus databases were used to search studies from 1984 to 2013. Results: Individuals with both congenital and acquired hemiparesis were able to some extent to use anticipatory motor control in precision grip tasks, even if this control was impaired in the paretic hand. In both congenital or acquired hemiparesis, the ability to plan efficient anticipatory motor control when the less-affected hand is used provides a possibility to remediate impairments in anticipatory motor control of the paretic hand. Conclusion: Surprisingly we observed very few differences between the results of studies in children with congenital hemiplegia and stroke patients. We suggest that the underlying specific strategies of neurorehabilitation developed for each one could benefit the other.

  3. The predictive value of the extensor grip test for the effectiveness of bracing for tennis elbow

    NARCIS (Netherlands)

    Struijs, Peter A. A.; Assendelft, Willem J. J.; Kerkhoffs, Gino M. M. J.; Souer, Sebastiaan; van Dijk, C. Niek

    2005-01-01

    Background: Tennis elbow is a common complaint. Several treatment strategies, such as corticosteroid injections and physical therapy and braces, have been described. Hypothesis: The extensor grip test has predictive value in assessing the effectiveness of bracing in tennis elbow. Study Design:

  4. Smoking impact on grip strength and fatigue resistance: implications for exercise and hand therapy practice.

    Science.gov (United States)

    Al-Obaidi, Saud; Al-Sayegh, Nowall; Nadar, Mohammed

    2014-07-01

    Grip strength assessment reflects on overall health of the musculoskeletal system and is a predictor of functional prognosis and mortality. The purpose of this study was: examine whether grip-strength and fatigue resistance are impaired in smokers, determine if smoking-related impairments (fatigue-index) can be predicted by demographic data, duration of smoking, packets smoked-per-day, and physical activity. Maximum isometric grip strength (MIGS) of male smokers (n = 111) and nonsmokers (n = 66) was measured before/after induced fatigue using Jamar dynamometer at 5-handle positions. Fatigue index was calculated based on percentage change in MIGS initially and after induced fatigue. Number of repetitions to squeeze the soft rubber ball to induce fatigue was significantly lower in smokers compared with nonsmokers (t = 10.6, P smoking status on MIGS scores was significantly different between smokers and nonsmokers after induced fatigue (β = -3.98, standard error = 0.59, P Smoking status was the strongest significant independent predictor of the fatigue-index. Smokers demonstrated reduced grip strength and fast fatigability in comparison with nonsmokers.

  5. Feeling is Believing: a location limited channel based on grip pattern biometrics and cryptanalysis

    NARCIS (Netherlands)

    Buhan, I.R.; Doumen, J.M.; Hartel, Pieter H.; Veldhuis, Raymond N.J.

    We use grip pattern based biometrics as a location limited channel to achieve pre-authentication in a protocol that sets up a secure cannel between two handheld devices. The protocol efficiently calculates a shared secret key from biometric data using quantization and cryptanalysis. The protocol is

  6. Grip strength and quality of life in the second half of life: hope as a moderator.

    Science.gov (United States)

    Gum, Amber M; Segal-Karpas, Dikla; Avidor, Sharon; Ayalon, Liat; Bodner, Ehud; Palgi, Yuval

    2017-09-28

    The purpose of the current study was to investigate grip strength, hope, and their interaction as predictors of quality of life four years later in a nationally representative sample of older adults. Data were derived from the first (2005-2006) and second wave (2009) of the Israeli component of the Survey of Health Ageing and Retirement in Europe (SHARE; N = 344). Hope was measured by three items from the Hope   Scale, and quality of life was measured by the CASP-12 (Control, Autonomy, Self-Realization, and Pleasure). Multiple regression analyses were conducted. Grip strength at T1 predicted QoL in T2, but hope was not a significant predictor. Furthermore, hope moderated the effect of handgrip on QoL, such that the effect was weaker for higher levels of hope. As hypothesized, hope acted as a moderator, such that poor grip strength was associated with worse QoL for less hopeful older adults, but grip strength was not associated with QoL for more hopeful older adults. Findings are consistent with a theoretical conceptualization of hope as a buffer between physical challenges and negative outcomes like QoL. Encouraging a hopeful perspective could enhance QoL for older adults with decreased muscle strength.

  7. EFFECT OF ECCENTRIC EXERCISE PROGRAMME ON PAIN AND GRIP STRENGTH FOR SUBJECTS WITH MEDIAL EPICONDYLITIS

    Directory of Open Access Journals (Sweden)

    Mishra Prashant Akhilesh

    2014-04-01

    Full Text Available Background and Objective: Therapeutic eccentric exercise may provide both a structural and functional benefit during tendinopathy rehabilitation. The objective is to find the effect of eccentric exercises on improvement of pain and grip strength for subjects with Medial Epicondylitis. Method: Pre to post test experimental study design randomized thirty subjects with medial epicondylitis, 15 each into Group A and Group B. Group B subjects were treated with conventional therapy and Eccentric exercises. Group A subjects were treated with conventional therapy. Results: When means of post intervention were compared using Independent ‘t’ between groups there was no statistically significant difference in improvements obtained in VAS scores and grip strength. There was a statistically significant change in means of VAS score and Grip strength when means were analyzed by using Paired‘t’ test and Wilcoxon signed rank test within the groups with positive percentage of change. Conclusion: It is concluded that four weeks of Eccentric Exercise Programme combined with conventional therapy shown significant effect on improving pain and Grip strength, however the improvement obtained has no difference when compared with control conventional treatment for Subjects with Medial Epicondylitis.

  8. Electrical conductivity measurements from the GISP2 and GRIP Greenland ice cores

    DEFF Research Database (Denmark)

    Dahl-Jensen, Dorthe; Clausen, Henrik Brink; Taylor, K. C.

    1993-01-01

    . Here we present electrical conductivity records for the Greenland Ice Sheet Project 2 (GISP2) and Greenland Ice-core Project (GRIP) ice cores, drilled 28 km apart to enable direct comparison of the results. The upper parts of both records are consistent with previous evidence from other Greenland cores...

  9. Dynamical Coordination of Hand Intrinsic Muscles for Precision Grip in Diabetes Mellitus.

    Science.gov (United States)

    Li, Ke; Wei, Na; Cheng, Mei; Hou, Xingguo; Song, Jun

    2018-03-12

    This study investigated the effects of diabetes mellitus (DM) on dynamical coordination of hand intrinsic muscles during precision grip. Precision grip was tested using a custom designed apparatus with stable and unstable loads, during which the surface electromyographic (sEMG) signals of the abductor pollicis brevis (APB) and first dorsal interosseous (FDI) were recorded simultaneously. Recurrence quantification analysis (RQA) was applied to quantify the dynamical structure of sEMG signals of the APB and FDI; and cross recurrence quantification analysis (CRQA) was used to assess the intermuscular coupling between the two intrinsic muscles. This study revealed that the DM altered the dynamical structure of muscle activation for the FDI and the dynamical intermuscular coordination between the APB and FDI during precision grip. A reinforced feedforward mechanism that compensates the loss of sensory feedbacks in DM may be responsible for the stronger intermuscular coupling between the APB and FDI muscles. Sensory deficits in DM remarkably decreased the capacity of online motor adjustment based on sensory feedback, rendering a lower adaptability to the uncertainty of environment. This study shed light on inherent dynamical properties underlying the intrinsic muscle activation and intermuscular coordination for precision grip and the effects of DM on hand sensorimotor function.

  10. Calpain-GRIP Signaling in Nucleus Accumbens Core Mediates the Reconsolidation of Drug Reward Memory.

    Science.gov (United States)

    Liang, Jie; Li, Jia-Li; Han, Ying; Luo, Yi-Xiao; Xue, Yan-Xue; Zhang, Yàn; Zhang, Yán; Zhang, Li-Bo; Chen, Man-Li; Lu, Lin; Shi, Jie

    2017-09-13

    Exposure to drug-paired cues causes drug memories to be in a destabilized state and interfering with memory reconsolidation can inhibit relapse. Calpain, a calcium-dependent neutral cysteine protease, is involved in synaptic plasticity and the formation of long-term fear memory. However, the role of calpain in the reconsolidation of drug reward memory is still unknown. In the present study, using a conditioned place preference (CPP) model, we found that exposure to drug-paired contextual stimuli induced the activation of calpain and decreased the expression of glutamate receptor interacting protein 1 (GRIP1) in the nucleus accumbens (NAc) core, but not shell, of male rats. Infusions of calpain inhibitors in the NAc core immediately after retrieval disrupted the reconsolidation of cocaine/morphine cue memory and blocked retrieval-induced calpain activation and GRIP1 degradation. The suppressive effect of calpain inhibitors on the expression of drug-induced CPP lasted for at least 14 d. The inhibition of calpain without retrieval 6 h after retrieval or after exposure to an unpaired context had no effects on the expression of reward memory. Calpain inhibition after retrieval also decreased cocaine seeking in a self-administration model and this effect did not recover spontaneously after 28 d. Moreover, the knock-down of GRIP1 expression in the NAc core by lentivirus-mediated short-hairpin RNA blocked disruption of the reconsolidation of drug cue memories that was induced by calpain inhibitor treatment. These results suggest that calpain activity in the NAc core is crucial for the reconsolidation of drug reward memory via the regulation of GRIP1 expression. SIGNIFICANCE STATEMENT Calpain plays an important role in synaptic plasticity and long-term memory consolidation, however, its role in the reconsolidation of drug cue memory remains unknown. Using conditioned place preference and self-administration procedures, we found that exposure to drug-paired cues induced the

  11. The properties and interrelationships of various force-time parameters during maximal repeated rhythmic grip.

    Science.gov (United States)

    Nakada, Masakatsu; Demura, Shinichi; Yamaji, Shunsuke

    2007-01-01

    The purpose of this study was to examine the properties and interrelationships of various force-time parameters including the inflection point for the rate of decline in force during a maximal repeated rhythmic grip. Fifteen healthy males (age M=21.5, SD=2.1 yr, height M=172.4, SD=5.7 cm, body mass M=68.2, SD=9.2 kg) participated in this study. Subjects performed a maximal repeated rhythmic grip with maximal effort with a target frequency of 30 grip.min(-1) for 6 min. The force value decreased linearly and markedly until about 70% of maximal strength for about 55 s after the onset of a maximal repeated rhythmic grip, and then decreased moderately. Because all parameters showed fair or good correlations between 3 min and 6 min, they are considered to be able to sufficiently evaluate muscle endurance for 3 min instead of 6 min. However, there were significant differences between 3 min and 6 min in the integrated area, the final force, the rate of the decrement constant (k) fitting the force decreasing data to y=ae(-kx)+b and the force of maximal difference between the force and a straight line from peak force to the final force. Their parameters may vary generally by the length of a steady state, namely, a measurement time. The final force value before finishing and the rate of the decrement constant (k) reflect the latter phase during a maximal repeated rhythmic grip. Although many parameters show relatively high mutual relationships, the rate constant (k) shows relatively low correlations with other parameters. We inferred that decreasing the time until 80% of maximal strength and the amount of the decrement force for the first 1 min reflect a linear decrease in the initial phase.

  12. Influences of load characteristics on impaired control of grip forces in patients with cerebellar damage.

    Science.gov (United States)

    Brandauer, B; Timmann, D; Häusler, A; Hermsdörfer, J

    2010-02-01

    Various studies showed a clear impairment of cerebellar patients to modulate grip force in anticipation of the loads resulting from movements with a grasped object. This failure corroborated the theory of internal feedforward models in the cerebellum. Cerebellar damage also impairs the coordination of multiple-joint movements and this has been related to deficient prediction and compensation of movement-induced torques. To study the effects of disturbed torque control on feedforward grip-force control, two self-generated load conditions with different demands on torque control-one with movement-induced and the other with isometrically generated load changes-were directly compared in patients with cerebellar degeneration. Furthermore the cerebellum is thought to be more involved in grip-force adjustment to self-generated loads than to externally generated loads. Consequently, an additional condition with externally generated loads was introduced to further test this hypothesis. Analysis of 23 patients with degenerative cerebellar damage revealed clear impairments in predictive feedforward mechanisms in the control of both self-generated load types. Besides feedforward control, the cerebellar damage also affected more reactive responses when the externally generated load destabilized the grip, although this impairment may vary with the type of load as suggested by control experiments. The present findings provide further support that the cerebellum plays a major role in predictive control mechanisms. However, this impact of the cerebellum does not strongly depend on the nature of the load and the specific internal forward model. Contributions to reactive (grip force) control are not negligible, but seem to be dependent on the physical characteristics of an externally generated load.

  13. Hand grip strength and maximum peak expiratory flow: determinants of bone mineral density of adolescent students.

    Science.gov (United States)

    Cossio-Bolaños, Marco; Lee-Andruske, Cynthia; de Arruda, Miguel; Luarte-Rocha, Cristian; Almonacid-Fierro, Alejandro; Gómez-Campos, Rossana

    2018-03-02

    Maintaining and building healthy bones during the lifetime requires a complicated interaction between a number of physiological and lifestyle factors. Our goal of this study was to analyze the association between hand grip strength and the maximum peak expiratory flow with bone mineral density and content in adolescent students. The research team studied 1427 adolescent students of both sexes (750 males and 677 females) between the ages of 11.0 and 18.9 years in the Maule Region of Talca (Chile). Weight, standing height, sitting height, hand grip strength (HGS), and maximum peak expiratory flow (PEF) were measured. Furthermore, bone mineral density (BMD) and total body bone mineral content (BMC) were determined by using the Dual-Energy X-Ray Absorptiometry (DXA). Hand grip strength and PEF were categorized in tertiles (lowest, middle, and highest). Linear regression was performed in steps to analyze the relationship between the variables. Differences between categories were determined through ANOVA. In males, the hand grip strength explained 18-19% of the BMD and 20-23% of the BMC. For the females, the percentage of variation occurred between 12 and 13% of the BMD and 17-18% of the BMC. The variation of PEF for the males was observed as 33% of the BMD and 36% of the BMC. For the females, both the BMD and BMC showed a variation of 19%. The HGS and PEF were divided into three categories (lowest, middle, and highest). In both cases, significant differences occurred in bone density health between the three categories. In conclusion, the HGS and the PEF related positively to the bone density health of both sexes of adolescent students. The adolescents with poor values for hand grip strength and expiratory flow showed reduced values of BMD and BMC for the total body. Furthermore, the PEF had a greater influence on bone density health with respect to the HGS of the adolescents of both sexes.

  14. Precision grip responses to unexpected rotational perturbations scale with axis of rotation.

    Science.gov (United States)

    De Gregorio, Michael; Santos, Veronica J

    2013-04-05

    It has been established that rapid, pulse-like increases in precision grip forces ("catch-up responses") are elicited by unexpected translational perturbations and that response latency and strength scale according to the direction of linear slip relative to the hand as well as gravity. To determine if catch-up responses are elicited by unexpected rotational perturbations and are strength-, axis-, and/or direction-dependent, we imposed step torque loads about each of two axes which were defined relative to the subject's hand: the distal-proximal axis away from and towards the subject's palm, and the grip axis which connects the two fingertips. Precision grip responses were dominated initially by passive mechanics and then by active, unimodal catch-up responses. First dorsal interosseous activity, marking the start of the catch-up response, began 71-89 ms after the onset of perturbation. The onset latency, shape, and duration (217-231 ms) of the catch-up response were not affected by the axis, direction, or magnitude of the rotational perturbation, while strength was scaled by axis of rotation and slip conditions. Rotations about the grip axis that tilted the object away from the palm and induced rotational slip elicited stronger catch-up responses than rotations about the distal-proximal axis that twisted the object between the digits. To our knowledge, this study is the first to investigate grip responses to unexpected torque loads and to show characteristic, yet axis-dependent, catch-up responses for conditions other than pure linear slip. Copyright © 2013 Elsevier Ltd. All rights reserved.

  15. An electromyographic study of the effect of hand grip sizes on forearm muscle activity and golf performance.

    Science.gov (United States)

    Sorbie, Graeme G; Hunter, Henry H; Grace, Fergal M; Gu, Yaodong; Baker, Julien S; Ugbolue, Ukadike Chris

    2016-01-01

    The study describes the differences in surface electromyography (EMG) activity of two forearm muscles in the lead and trail arm at specific phases of the golf swing using a 7-iron with three different grip sizes among amateur and professional golfers. Fifteen right-handed male golfers performed five golf swings using golf clubs with three different grip sizes. Surface EMG was used to measure muscle activity of the extensor carpi radialis brevis (ECRB) and flexor digitorum superficialis (FDS) on both forearms. There were no significant differences in forearm muscle activity when using the three golf grips within the group of 15 golfers (p > 0.05). When using the undersize grip, club head speed significantly increased (p = 0.044). During the backswing and downswing phases, amateurs produced significantly greater forearm muscle activity with all three grip sizes (p < 0.05). In conclusion, forearm muscle activity is not affected by grip sizes. However, club head speed increases when using undersize grips.

  16. Ulnar digits contribution to grip strength in patients with thumb carpometacarpal osteoarthritis is less than in normal controls.

    Science.gov (United States)

    Villafañe, Jorge H; Valdes, Kristin; Angulo-Diaz-Parreño, Santiago; Pillastrini, Paolo; Negrini, Stefano

    2015-06-01

    Grip testing is commonly used as an objective measure of strength in the hand and upper extremity and is frequently used clinically as a proxy measure of function. Increasing knowledge of hand biomechanics, muscle strength, and prehension patterns can provide us with a better understanding of the functional capabilities of the hand. The objectives of this study were to determine the contribution of ulnar digits to overall grip strength in individuals with thumb carpometacarpal (CMC) osteoarthritis (OA). Thirty-seven subjects participated in the study. This group consisted of 19 patients with CMC OA (aged 60-88 years) and 18 healthy subjects (60-88 years). Three hand configurations were used by the subjects during grip testing: use of the entire hand (index, middle, ring, and little fingers) (IMRL); use of the index, middle, and ring fingers (IMR); and use of only the index and middle fingers (IM). Grip strength findings for the two groups found that compared to their healthy counterparts, CMC OA patients had, on average, a strength deficiency of 45.6, 35.5, and 28.8 % in IMRL, IMR, and IM, respectively. The small finger contribution to grip is 14.3 % and the ring and small finger contribute 34 % in subjects with CMC OA. Grip strength decreases as the number of digits contributing decreased in both groups. The ulnar digits contribution to grip strength is greater than one third of total grip strength in subjects with CMC OA. Individuals with CMC OA demonstrate significantly decreased grip strength when compared to their healthy counterparts.

  17. Functional relationship between dominant and non-dominant hand in motor task - hand grip strength endurance

    Directory of Open Access Journals (Sweden)

    Kljajić Dragana

    2012-01-01

    Full Text Available The aim of this study was to determine the functional relationship between dominant and non-dominant hand in the strength endurance motor task - hand grip, in the referent population of healthy and young persons. For the purpose of the research we have implemented the method of isometric dynamometry and standardized hand grip test. The study included 48 participants, 23 of them being of female and 25 of male gender. The analysis of variance (ANOVA was used to determine the difference between the sets of variables in the function of gender and functional dimorphism, while the Bonferroni criterion was applied to determine the differences between pairs of individual variables. The difference between the maximum hand grip of dominant and non-dominant hand in female participants amounted to 9.28%, and in male ones 7.39% in favor of the dominant hand. There is no statistically significant difference between nondominant and dominant hand regarding the force endurance time aspect at 30%, 50% and 80% out of the maximum hand grip level, as well as at the absolute and relative force impulse indicators as an endurance measure. The value of gender dimorphism in relation to the absolute indicators of force momentum at 30%, 50% and 80% out of the maximum hand grip level in female participants is 0.9714, 0.9145, 0.9301, and in male participants 0.9515, 0.8264 and 0.8606. The force momentum indicators value at 30%, 50% and 80% out of the maximum hand grip level in female participants is ImpF30%=21167.58±6923.67 Ns, ImpF50%=10846.94±3800.56 Ns and ImpF80%=5438.46±1993.12 Ns, and in male participants ImpF30%=17734.03±6881.92 Ns, ImpF50%=13903.61±3437.76 Ns and ImpF80%=5117.53±1894.78 Ns. The obtained results can be used as the criteria for further research in special education and rehabilitation, medical and professional rehabilitation.

  18. Nutritional status is the major factor affecting grip strength of African HIV patients before and during antiretroviral treatment

    DEFF Research Database (Denmark)

    Filteau, Suzanne; PrayGod, G; Woodd, Susannah L

    2017-01-01

    OBJECTIVES: Low grip strength is a marker of frailty and a risk factor for mortality among HIV patients and other populations. We investigated factors associated with grip strength in malnourished HIV patients at referral to ART, and at 12 weeks and 2-3 years after starting ART. METHODS: The study...... involved HIV-infected Zambian and Tanzanian participants recruited to the NUSTART trial when malnourished (body mass index .... CONCLUSIONS: In this population of originally malnourished HIV patients, poor grip strength was more strongly and independently associated with nutritional than with infection and inflammation variables. Programmes to improve health and survival of HIV patients should incorporate nutritional assessment...

  19. Comprehension of handwriting development: Pen-grip kinetics in handwriting tasks and its relation to fine motor skills among school-age children.

    Science.gov (United States)

    Lin, Yu-Chen; Chao, Yen-Li; Wu, Shyi-Kuen; Lin, Ho-Hsio; Hsu, Chieh-Hsiang; Hsu, Hsiao-Man; Kuo, Li-Chieh

    2017-10-01

    Numerous tools have been developed to evaluate handwriting performances by analysing written products. However, few studies have directly investigated kinetic performances of digits when holding a pen. This study thus attempts to investigate pen-grip kinetics during writing tasks of school-age children and explore the relationship between the kinetic factors and fine motor skills. This study recruited 181 children aged from 5 to 12 years old and investigated the effects of age on handwriting kinetics and the relationship between these and fine motor skills. The forces applied from the digits and pen-tip were measured during writing tasks via a force acquisition pen, and the children's fine motor performances were also evaluated. The results indicate that peak force and average force might not be direct indicators of handwriting performance for normally developing children at this age. Younger children showed larger force variation and lower adjustment frequency during writing, which might indicate they had poorer force control than the older children. Force control when handling a pen is significantly correlated with fine motor performance, especially in relation to the manual dexterity. A novel system is proposed for analysing school-age children's force control while handwriting. We observed the development of force control in relation to pen grip among the children with different ages in this study. The findings suggested that manipulation skill may be crucial when children are establishing their handwriting capabilities. © 2017 Occupational Therapy Australia.

  20. Organism versus mechanism: Losing our grip on the distinction

    Directory of Open Access Journals (Sweden)

    Henk Reitsema

    2013-11-01

    Full Text Available The distinction between organism and mechanism is often subtle or unclear and yet can prove to be fundamental to our understanding of the world. It has been tempting for many thinkers to seek to ‘understand’ all of reality through the lens of either the one or the other of these concepts rather than by giving both a place. This article sets out to argue that there is a substantial loss of understanding when either of these metaphors is absolutised to explain all causal processes and patterns in reality. Clarifying the distinction between the two may provide one more tool to grasp what is reductionist in many of the perspectives that have come to dominate public life and science today. This contention is tested on the quest for the design of self-replicating systems (i.e. synthetic organisms in the nanotech industry. It is common that the concepts of organic functioning and mechanism are used imprecisely and in an overlapping way. This is also true of much scientific debate, especially in the fields of biology, micro-biology and nano-science. This imprecise use signals a reductionist tendency both in the way that the organic is perceived and in terms of the distinctive nature of mechanisms.

  1. The effects of cold immersion and hand protection on grip strength.

    Science.gov (United States)

    Vincent, M J; Tipton, M J

    1988-08-01

    The maximal voluntary grip strength (MVGS) of male volunteers was examined following a series of five intermittent 2 min cold water (5 degrees C) immersions of the unprotected hand or forearm. MVGS changes due to wearing a protective glove were also investigated. The surface electrical activity over the hand flexor muscles was recorded, as was the skin temperature of the hand and forearm. MVGS decreased significantly (p less than 0.01) following hand immersions (16%) and forearm immersion (13%). The majority of these reductions occurred during the first 2-min period of immersion. The effect of wearing a glove after unprotected hand cooling also produced significant (p less than 0.01) MVGS reductions which averaged 14%. These reductions were in addition to those caused by hand cooling. We conclude that both hand and forearm protection are important for the maintenance of hand-grip strength following cold water immersion.

  2. A Monte Carlo-tuned model of the flow in the NorthGRIP area

    DEFF Research Database (Denmark)

    Grinsted, Aslak; Dahl-Jensen, Dorthe

    2002-01-01

    The North Greenland Icecore Project (NorthGRIP) drill site was chosen in order to obtain a good Eemian record. At the present depth, 3001m, the Eemian interstadial has yet to be seen. Clearly the flow in this area is poorly understood and needs further investigation. After a review of specific...... no Eemian is observed is a high basal melt rate (2.7mm/a). The melting is a consequence of a higher geothermal heat flux than the expected 51mW/m^2 of the Precambrian shield. From our analyses it is concluded that the geothermal heat flux at NorthGRIP is 98mW/m^2.The high basalmelt rate also gives rise...

  3. Corticomuscular coherence during hand gripping with DBS and medication in PD patients

    DEFF Research Database (Denmark)

    Sridharan, Kousik Sarathy; Højlund, Andreas; Johnsen, Erik Lisbjerg

    Deep brain stimulation (DBS) effectively alleviates the motor symptoms in Parkinson’s disease (PD) although its effect mechanism is still unclear. CMC is reduced in PD patients but restorable with medication, while DBS variably affects CMC in advanced PD patients. We recorded magnetoencephalography...... (MEG) from six PD patients performing hand gripping during DBS ON and medicated (levodopa, MED ON) conditions and from ten age-matched healthy controls. Participants performed isotonic contractions (hand gripping) with their right hand, and electromyography (EMG) was recorded from the extensor...... digitorum communis muscle with a belly-tendon montage. We calculated the mean-squared coherence between MEG and the rectified EMG signals. For each group and condition, we selected the maximum CMC value in the beta range (13-30 Hz) within the average of an a priori selection of nine left sensorimotor...

  4. Ancient death-grip leaf scars reveal ant–fungal parasitism

    Science.gov (United States)

    Hughes, David P.; Wappler, Torsten; Labandeira, Conrad C.

    2011-01-01

    Parasites commonly manipulate host behaviour, and among the most dramatic examples are diverse fungi that cause insects to die attached to leaves. This death-grip behaviour functions to place insects in an ideal location for spore dispersal from a dead body following host death. Fossil leaves record many aspects of insect behaviour (feeding, galls, leaf mining) but to date there are no known examples of behavioural manipulation. Here, we document, to our knowledge, the first example of the stereotypical death grip from 48 Ma leaves of Messel, Germany, indicating the antiquity of this behaviour. As well as probably being the first example of behavioural manipulation in the fossil record, these data support a biogeographical parallelism between mid Eocene northern Europe and recent southeast Asia. PMID:20719770

  5. Ancient death-grip leaf scars reveal ant-fungal parasitism.

    Science.gov (United States)

    Hughes, David P; Wappler, Torsten; Labandeira, Conrad C

    2011-02-23

    Parasites commonly manipulate host behaviour, and among the most dramatic examples are diverse fungi that cause insects to die attached to leaves. This death-grip behaviour functions to place insects in an ideal location for spore dispersal from a dead body following host death. Fossil leaves record many aspects of insect behaviour (feeding, galls, leaf mining) but to date there are no known examples of behavioural manipulation. Here, we document, to our knowledge, the first example of the stereotypical death grip from 48 Ma leaves of Messel, Germany, indicating the antiquity of this behaviour. As well as probably being the first example of behavioural manipulation in the fossil record, these data support a biogeographical parallelism between mid Eocene northern Europe and recent southeast Asia.

  6. Grips for testing of electrical characteristics of a specimen under a mechanical load

    Science.gov (United States)

    Briggs, Timothy; Loyola, Bryan

    2018-04-24

    Various technologies to facilitate coupled electrical and mechanical measurement of conductive materials are disclosed herein. A gripping device simultaneously holds a specimen in place and causes contact to be made between the specimen and a plurality of electrodes connected to an electrical measuring device. An electrical characteristic of the specimen is then measured while a mechanical load is applied to the specimen, and a relationship between the mechanical load and changes in the electrical characteristic can be identified.

  7. Interactive effects of music tempi and intensities on grip strength and subjective affect.

    Science.gov (United States)

    Karageorghis, C I; Cheek, P; Simpson, S D; Bigliassi, M

    2018-03-01

    Pretask music is widely used by athletes albeit there is scant empirical evidence to support its use. The present study extended a line of work into pretask music by examining the interactive effects of music tempo and intensity (volume) on the performance of a simple motor skill and subjective affect. A 2 × 2 within-subjects factorial design was employed with an additional no-music control, the scores from which were used as a covariate. A sample of 52 male athletes (M age  = 26.1 ± 4.8 years) was exposed to five conditions: fast/loud (126 bpm/80 dBA), fast/quiet (126 bpm/70 dBA), slow/loud (87 bpm/80 dBA), slow/quiet (87 bpm/70 dBA) music, and a no-music control. Dependent variables were grip strength, measured with a handgrip dynamometer, and subjective affect, assessed by use of the Affect Grid. The tempo and intensity components of music had interactive effects for grip strength but only main effects for subjective affect. Fast-tempo music played at a high intensity yielded the highest grip strength, while fast-tempo music played at a low-intensity resulted in much lower grip strength (M diff.  = -1.11 Force kg). For affective valence, there were main effects of tempo and intensity, with fast and loud music yielding the highest scores. For affective arousal, there was no difference between tempi although there was between intensities, with the high-intensity condition yielding higher scores. The present findings indicate the utility of fast/loud pretask music in enhancing affective valence and arousal in preparation for a simple or gross motor task. © 2017 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  8. Mind Your Grip: Even Usual Dexterous Manipulation Requires High Level Cognition

    Directory of Open Access Journals (Sweden)

    Erwan Guillery

    2017-11-01

    Full Text Available Simultaneous execution of cognitive and sensorimotor tasks is critical in daily life. Here, we examined whether dexterous manipulation, a highly habitual and seemingly automatic behavior, involves high order cognitive functions. Specifically, we explored the impact of reducing available cognitive resources on the performance of a precision grip-lift task in healthy participants of three age groups (18–30, 30–60 and 60–75 years. Participants performed a motor task in isolation (M, in combination with a low-load cognitive task (M + L, and in combination with a high-load cognitive task (M + H. The motor task consisted in grasping, lifting and holding an apparatus instrumented with force sensors to monitor motor task performance. In the cognitive task, a list of letters was shown briefly before the motor task. After completing the motor task, one letter of the list was shown, and participants reported the following letter of the list. In M + L, letters in the list followed the alphabetical order. In M + H, letters were presented in random order. Performing the high-load task thus required maintaining information in working memory. Temporal and dynamic parameters of grip and lift forces were compared across conditions. During the cognitive tasks, there was a significant alteration of movement initiation and a significant increase of grip force (GF throughout the grip-lift task. There was no interaction with “age”. Our results demonstrate that planning and the on-line control of dexterous manipulation is not an automatic behavior and, instead, that it interacts with high-level cognitive processes such as those involved in working memory.

  9. Relationship among maximal grip, throwing velocity and anthropometric parameters in elite water polo players.

    Science.gov (United States)

    Ferragut, C; Vila, H; Abraldes, J A; Argudo, F; Rodriguez, N; Alcaraz, P E

    2011-03-01

    As independent aspects, body size, body composition, and physiological performance of elite athletes have aroused the interest of sports scientists but, unfortunately, studies that combine these aspects are scarcely avalaible in water polo. The aim of the present study was to: 1) to develop an anthropometric profile of highly skilled male Water Polo players, and 2) to identify significant relationships between these features and overhead throwing velocity in highly skilled male water polo players. Thirteen male water polo players, with a mean age of 26.10±4.82, were recruited from the Spanish Water Polo team and an anthropometric assessment on all of them was carried out. Throwing velocity was evaluated in three different situations from the 5 m-penalty line on the center of the water polo goal: A) throwing without a defender nor a goalkeeper; B) throwing with a goalkeeper only, and C) 3) armfuls running shot with goalkeeper. Maximal handgrip was also tested. Biacromial breadth shows a significative correlation with hand grip in water polo players (r=0.792; P=0.001) and also correlates with Throwing velocity (r=0.716; P<0.001). Biepicondylar femur breadth correlates significatively with hand grip (r=0.727; P<0.05) and also with throwing velocity in "throwing with goalkeeper" situation (r=0.664; P<0.05). Hand grip shows a significant correlation with throwing velocity in "throwing with goalkeeper" situation (r=0.603; P<0.05). In conclusion, body mass aspects are not related with throwing velocity in highly skilled Water Polo players. Maximal hand grip is related with throwing velocity in "throwing with goalkeeper" situation. More investigations about water polo are necessary.

  10. Serotonergic-postsynaptic receptors modulate gripping-induced immobility episodes in male taiep rats.

    Science.gov (United States)

    Eguibar, José R; Cortés, M C; Ita, M L

    2009-09-01

    The Taiep rat is a myelin mutant with a motor syndrome characterized by tremor, ataxia, immobility, epilepsy, and paralysis. The rat shows a hypomyelination followed by a progressive demyelination. During immobilities taiep rats show a REM-like sleep pattern and a disorganized sleep-wake pattern suggesting taiep rats as a model of narcolepsy-cataplexy. Our study analyzed the role of postsynaptic serotonin receptors in the expression of gripping-induced immobility episodes (IEs) in 8-month-old male taiep rats. The specific postsynaptic serotonin agonist +/-1-(2,5-dimethoxy-4-iodoamphetamine hydrochloride (+/-DOI) decreased the frequency of gripping-induced IEs, but that was not the case with alpha-methyl-serotonin maleate (alpha-methyl-5HT), a nonspecific postsynaptic agonist. Although the serotonin antagonists, ketanserine and metergoline, produced a biphasic effect, first a decrease followed by an increase with higher doses, similar effects were obtained with a mean duration of gripping-induced IEs. These findings correlate with the pharmacological observations in narcoleptic dogs and humans in which serotonin-reuptake inhibitors improve cataplexy, particularly in long-term treatment that could change the serotonin receptor levels. Polysomnographic recordings showed an increase in the awakening time and a decrease in the slow wave and rapid eye movement sleep concomitant with a decrease in immobilities after use of +/-DOI, this being stronger with the highest dose. Taken together, our results show that postsynaptic serotonin receptors are involved in the modulation in gripping-induced IEs caused by the changes in the organization of the sleep-wake cycle in taiep rats. It is possible that specific agonists, without side effects, could be a useful treatment in human narcoleptic patients. 2009 Wiley-Liss, Inc.

  11. Finger pressure adjustments to various object configurations during precision grip in humans and monkeys.

    Science.gov (United States)

    Viaro, Riccardo; Tia, Banty; Coudé, Gino; Canto, Rosario; Oliynyk, Andriy; Salmas, Paola; Masia, Lorenzo; Sandini, Giulio; Fadiga, Luciano

    2017-06-01

    In this study, we recorded the pressure exerted onto an object by the index finger and the thumb of the preferred hand of 18 human subjects and either hand of two macaque monkeys during a precision grasping task. The to-be-grasped object was a custom-made device composed by two plates which could be variably oriented by a motorized system while keeping constant the size and thus grip dimension. The to-be-grasped plates were covered by an array of capacitive sensors to measure specific features of finger adaptation, namely pressure intensity and centroid location and displacement. Kinematic measurements demonstrated that for human subjects and for monkeys, different plate configurations did not affect wrist velocity and grip aperture during the reaching phase. Consistently, at the instant of fingers-plates contact, pressure centroids were clustered around the same point for all handle configurations. However, small pressure centroid displacements were specifically adopted for each configuration, indicating that both humans and monkeys can display finger adaptation during precision grip. Moreover, humans applied stronger thumb pressure intensity, performed less centroid displacement and required reduced adjustment time, as compared to monkeys. These pressure patterns remain similar when different load forces were required to pull the handle, as ascertained by additional measurements in humans. The present findings indicate that, although humans and monkeys share common features in motor control of grasping, they differ in the adjustment of fingertip pressure, probably because of skill and/or morphology divergences. Such a precision grip device may form the groundwork for future studies on prehension mechanisms. © 2017 Federation of European Neuroscience Societies and John Wiley & Sons Ltd.

  12. Influence of the gripping fixture on the modified compact tension test results: Evaluation of the experiments on cylindrical concrete specimens

    Czech Academy of Sciences Publication Activity Database

    Holušová, T.; Lozano, M.; Canteli, A.; Komárková, T.; Kocáb, D.; Seitl, Stanislav

    2015-01-01

    Roč. 15, č. 2 (2015) ISSN 1804-4824 Institutional support: RVO:68081723 Keywords : Modified compact tension test * fracture parametr * Cementitious composites * Aramis measurement * grips Subject RIV: JL - Materials Fatigue, Friction Mechanics

  13. Limited Investigation of the Effects of Elevator Rate Limiting and Stick Dynamics on Longitudinal Pilot Induced Oscillations (HAVE GRIP)

    National Research Council Canada - National Science Library

    Peters, Patrick

    1996-01-01

    This report presents the results of the HAVE GRIP flight test program. This program performed a limited investigation of the effects of stick dynamics and elevator rate limiting on longitudinal pilot induced oscillations (PIOs...

  14. Interobserver reproducibility of the assessment of severity of complaints, grip strength, and pressure pain threshold in patients with lateral epicondylitis.

    NARCIS (Netherlands)

    Smidt, N.; Windt, A. van der; Assendelft, W.J.; Mourits, A.J.; Devillé, W.L.; Winter, F. de; Bouter, L.M.

    2002-01-01

    Objective: To evaluate the interobserver reproducibility of the assessment of severity of complaints, grip strength, and pressure pain threshold in patients with lateral epicondylitis in primary care. Design: Two physiotherapists assessed independently, and in randomized order, the severity of

  15. Interobserver reproducibility of the assessment of severity of complaints, grip strength, and pressure pain threshold in patients with lateral epicondylitis

    NARCIS (Netherlands)

    Smidt, N; van der Windt, DA; Assendelft, WJ; Mourits, AJ; Deville, WL; de Winter, AF; Bouter, LM

    Objective: To evaluate the interobserver reproducibility of the assessment of severity of complaints, grip strength, and pressure pain threshold in patients with lateral epicondylitis in primary care. Design: Two physiotherapists assessed independently, and in randomized order, the severity of

  16. Cortical activation during power grip task with pneumatic pressure gauge: an fMRI study

    Science.gov (United States)

    Mohamad, M.; Mardan, N. H.; Ismail, S. S.

    2017-05-01

    Aging is associated with a decline in cognitive and motor function. But, the relationships with motor performance are less well understood. In this study, functional magnetic resonance imaging (fMRI) was used to assess cortical activation in older adults. This study employed power grip task that utilised block paradigm consisted of alternate 30s rest and active. A visual cue was used to pace the hand grip movement that clenched a cylindrical rubber bulb connected with pressure pneumatic gauge that measure the pressure (Psi). The objective of this study is determined the brain areas activated during motor task and the correlation between percentage signal change of each motor area (BA 4 and 6) and hand grip pressure. Result showed there was a significant difference in mean percentage signal change in BA 4 and BA 6 in both hemispheres and negative correlation obtained in BA 4 and BA 6. These results indicate that a reduced ability in the motor networks contribute to age-related decline in motor performance.

  17. Cortical activation during power grip task with pneumatic pressure gauge: an fMRI study

    International Nuclear Information System (INIS)

    Mohamad, M; Ismail, S S; Mardan, N H

    2017-01-01

    Aging is associated with a decline in cognitive and motor function. But, the relationships with motor performance are less well understood. In this study, functional magnetic resonance imaging (fMRI) was used to assess cortical activation in older adults. This study employed power grip task that utilised block paradigm consisted of alternate 30s rest and active. A visual cue was used to pace the hand grip movement that clenched a cylindrical rubber bulb connected with pressure pneumatic gauge that measure the pressure (Psi). The objective of this study is determined the brain areas activated during motor task and the correlation between percentage signal change of each motor area (BA 4 and 6) and hand grip pressure. Result showed there was a significant difference in mean percentage signal change in BA 4 and BA 6 in both hemispheres and negative correlation obtained in BA 4 and BA 6. These results indicate that a reduced ability in the motor networks contribute to age-related decline in motor performance. (paper)

  18. Relationships between Mechanical Variables in the Traditional and Close-Grip Bench Press.

    Science.gov (United States)

    Lockie, Robert G; Callaghan, Samuel J; Moreno, Matthew R; Risso, Fabrice G; Liu, Tricia M; Stage, Alyssa A; Birmingham-Babauta, Samantha A; Stokes, John J; Giuliano, Dominic V; Lazar, Adrina; Davis, DeShaun L; Orjalo, Ashley J

    2017-12-01

    The study aim was to determine relationships between mechanical variables in the one-repetition maximum (1RM) traditional bench press (TBP) and close-grip bench press (CGBP). Twenty resistance-trained men completed a TBP and CGBP 1RM. The TBP was performed with the preferred grip; the CGBP with a grip width of 95% biacromial distance. A linear position transducer measured: lift distance and duration; work; and peak and mean power, velocity, and force. Paired samples t-tests (p velocity was greater for the CGBP (d = 0.50-1.29). The 1RM TBP correlated with CGBP 1RM, power, and force (r = 0.685-0.982). TBP work correlated with CGBP 1RM, lift distance, power, force, and work (r = 0.542-0.931). TBP power correlated with CGBP 1RM, power, force, velocity, and work (r = 0.484-0.704). TBP peak and mean force related to CGBP 1RM, power, and force (r = 0.596-0.980). Due to relationships between the load, work, power, and force for the TBP and CGBP, the CGBP could provide similar strength adaptations to the TBP with long-term use. The velocity profile for the CGBP was different to that of the TBP. The CGBP could be used specifically to improve high-velocity, upper-body pushing movements.

  19. Nutritional status is the major factor affecting grip strength of African HIV patients before and during antiretroviral treatment.

    Science.gov (United States)

    Filteau, S; PrayGod, G; Woodd, S L; Friis, H; Heimburger, D C; Koethe, J R; Kelly, P; Kasonka, L; Rehman, A M

    2017-10-01

    Low grip strength is a marker of frailty and a risk factor for mortality among HIV patients and other populations. We investigated factors associated with grip strength in malnourished HIV patients at referral to ART, and at 12 weeks and 2-3 years after starting ART. The study involved HIV-infected Zambian and Tanzanian participants recruited to the NUSTART trial when malnourished (body mass index <18.5 kg/m 2 ) and requiring ART. The relationship of grip strength to nutritional, infectious and demographic factors was assessed by multivariable linear regression at referral for ART (n = 1742) and after 12 weeks (n = 778) and 2-3 years of ART (n = 273). In analyses controlled only for sex, age and height, most nutrition and infection-related variables were associated with grip strength. However, in multivariable analyses, consistent associations were seen for fat-free mass index, mid-upper arm circumference, haemoglobin and systolic blood pressure, and a variable association with fat mass index in men. C-reactive protein and CD4 count had limited independent effects on grip strength, while receiving tuberculosis treatment was associated with weaker grip strength. In this population of originally malnourished HIV patients, poor grip strength was more strongly and independently associated with nutritional than with infection and inflammation variables. Programmes to improve health and survival of HIV patients should incorporate nutritional assessment and management and could use grip strength as a functional indicator of improving nutrition. © 2017 John Wiley & Sons Ltd.

  20. Grip strength is not associated with incident type 2 diabetes mellitus in healthy adults: The CoLaus study.

    Science.gov (United States)

    Marques-Vidal, Pedro; Vollenweider, Peter; Waeber, Gérard; Jornayvaz, François R

    2017-10-01

    We examined the association of grip strength with incident type 2 diabetes mellitus (T2DM) in healthy subjects initially aged 50 to 75years after a follow-up of 5.5years and 10.7years. This was a prospective, population-based study derived from the CoLaus (Cohorte Lausannoise) study including 2318 participants (aged 60.2y; 1354 women) free from T2DM at baseline. Grip strength was assessed using a handheld dynamometer. The effect of grip strength on the incidence of T2DM was analyzed by logistic regression. After a follow-up of 5.5years, 190 (8.2%) T2DM cases were identified. In bivariate analysis, participants who developed T2DM had a higher absolute grip strength (35.3±10.6 versus 33.2±10.7kg, P=0.013). Analysis between grip strength expressed in 5kg increment and incident TD2M showed a negative association when adjusted for age and sex [ORs (95% CI): 0.88 (0.79, 0.98)], or for age, sex and body mass index (BMI) [ORs (95% CI): 0.87 (0.78, 097)]. After a follow-up of 10.7years, 131 supplemental (7.3%) T2DM cases were identified, but there was no association between grip strength and incident T2DM in bivariate and multivariable analysis, potentially due to a lack of statistical power. In non elderly healthy adults, the risk of incident T2DM is overall not associated with grip strength over a maximum follow-up of 10.7years. Future studies are warranted to better assess the association between grip strength and incident T2DM in bigger and even younger cohorts. Copyright © 2017 Elsevier B.V. All rights reserved.

  1. A positive action handling tool for TRIGA fuel

    International Nuclear Information System (INIS)

    McMaster, Ira B.

    1976-01-01

    Because several elements have disengaged accidentally from the conventional fuel handling tool at the PSBR a need was apparent for a tool whose action was more positive. The new design utilizes rotary motion to provide a positive locking action when the tool engages an element. This action provides a secure grip on the element and positive control by the tool operator over when an element can disengage from the tool. The convenience provided by the flexibility of the original tool is retained by making the lower four feet of the new tool flexible. (author)

  2. Grip Strength Is Associated With Cognitive Performance in Schizophrenia and the General Population: A UK Biobank Study of 476559 Participants.

    Science.gov (United States)

    Firth, Joseph; Stubbs, Brendon; Vancampfort, Davy; Firth, Josh A; Large, Matthew; Rosenbaum, Simon; Hallgren, Mats; Ward, Philip B; Sarris, Jerome; Yung, Alison R

    2018-04-19

    Handgrip strength may provide an easily-administered marker of cognitive functional status. However, further population-scale research examining relationships between grip strength and cognitive performance across multiple domains is needed. Additionally, relationships between grip strength and cognitive functioning in people with schizophrenia, who frequently experience cognitive deficits, has yet to be explored. Baseline data from the UK Biobank (2007-2010) was analyzed; including 475397 individuals from the general population, and 1162 individuals with schizophrenia. Linear mixed models and generalized linear mixed models were used to assess the relationship between grip strength and 5 cognitive domains (visual memory, reaction time, reasoning, prospective memory, and number memory), controlling for age, gender, bodyweight, education, and geographical region. In the general population, maximal grip strength was positively and significantly related to visual memory (coefficient [coeff] = -0.1601, standard error [SE] = 0.003), reaction time (coeff = -0.0346, SE = 0.0004), reasoning (coeff = 0.2304, SE = 0.0079), number memory (coeff = 0.1616, SE = 0.0092), and prospective memory (coeff = 0.3486, SE = 0.0092: all P reasoning (P > .1). Grip strength is significantly associated with cognitive functioning in the general population and individuals with schizophrenia, particularly for working memory and processing speed. Future research should establish directionality, examine if grip strength also predicts functional and physical health outcomes in schizophrenia, and determine whether interventions which improve muscular strength impact on cognitive and real-world functioning.

  3. Stress examination of flexor tendon pulley rupture in the crimp grip position: a 1.5-Tesla MRI cadaver study

    Energy Technology Data Exchange (ETDEWEB)

    Bayer, Thomas; Janka, Rolf [University of Erlangen-Nuremberg, Department of Radiology, Erlangen (Germany); Fries, Simon [Cantonal Hospital Lucerne, Orthopaedic Department, Wolhusen (Switzerland); Schweizer, Andreas [University of Zurich, Department of Orthopaedics, Balgrist, Zurich (Switzerland); Schoeffl, Isabelle [Klinikum Bamberg, Department of Pediatrics, Bamberg (Germany); Bongartz, Georg [University Basel, Department of Radiology, Basel (Switzerland)

    2015-01-15

    The objectives of this study were the evaluation of flexor tendon pulley rupture of the fingers in the crimp grip position using magnetic resonance imaging (MRI) and the comparison of the results with MRI in the neutral position in a cadaver study. MRI in the crimp grip position and in the neutral position was performed in 21 cadaver fingers with artificially created flexor tendon pulley tears (combined pulley rupture, n = 14; single pulley rupture, n = 7). Measurement of the distance between the tendon and bone was performed. Images were evaluated by two readers, first independently and in cases of discrepancy in consensus. Sensitivity and specificity for detecting combined pulley ruptures were calculated. Tendon bone distances were significantly higher in the crimp grip position than in the neutral position. Sensitivity and specificity for detecting combined pulley rupture were 92.86 % and 100 % respectively in the crimp grip position and 78.57 % and 85.71 % respectively in the neutral position. Kappa values for interobserver reliability were 0.87 in the crimp grip position and 0.59 in the neutral position. MRI examination in the crimp grip position results in higher tendon bone distances by subjecting the pulleys to a higher strain, which facilitates image evaluation with higher interobserver reliability, higher sensitivity, and higher specificity for combined pulley rupture compared with examination in the neutral position. (orig.)

  4. Transcranial direct current stimulation over multiple days enhances motor performance of a grip task.

    Science.gov (United States)

    Fan, Julie; Voisin, Julien; Milot, Marie-Hélène; Higgins, Johanne; Boudrias, Marie-Hélène

    2017-09-01

    Recovery of handgrip is critical after stroke since it is positively related to upper limb function. To boost motor recovery, transcranial direct current stimulation (tDCS) is a promising, non-invasive brain stimulation technique for the rehabilitation of persons with stroke. When applied over the primary motor cortex (M1), tDCS has been shown to modulate neural processes involved in motor learning. However, no studies have looked at the impact of tDCS on the learning of a grip task in both stroke and healthy individuals. To assess the use of tDCS over multiple days to promote motor learning of a grip task using a learning paradigm involving a speed-accuracy tradeoff in healthy individuals. In a double-blinded experiment, 30 right-handed subjects (mean age: 22.1±3.3 years) participated in the study and were randomly assigned to an anodal (n=15) or sham (n=15) stimulation group. First, subjects performed the grip task with their dominant hand while following the pace of a metronome. Afterwards, subjects trained on the task, at their own pace, over 5 consecutive days while receiving sham or anodal tDCS over M1. After training, subjects performed de novo the metronome-assisted task. The change in performance between the pre and post metronome-assisted task was used to assess the impact of the grip task and tDCS on learning. Anodal tDCS over M1 had a significant effect on the speed-accuracy tradeoff function. The anodal tDCS group showed significantly greater improvement in performance (39.28±15.92%) than the sham tDCS group (24.06±16.35%) on the metronome-assisted task, t(28)=2.583, P=0.015 (effect size d=0.94). Anodal tDCS is effective in promoting grip motor learning in healthy individuals. Further studies are warranted to test its potential use for the rehabilitation of fine motor skills in stroke patients. Copyright © 2017 Elsevier Masson SAS. All rights reserved.

  5. Quantification of hand function by power grip and pinch strength force measurements in ulnar nerve lesion simulated by ulnar nerve block.

    Science.gov (United States)

    Wachter, Nikolaus Johannes; Mentzel, Martin; Krischak, Gert D; Gülke, Joachim

    2017-06-24

    In the assessment of hand and upper limb function, grip strength is of the major importance. The measurement by dynamometers has been established. In this study, the effect of a simulated ulnar nerve lesion on different grip force measurements was evaluated. In 25 healthy volunteers, grip force measurement was done by the JAMAR dynamometer (Fabrication Enterprises Inc, Irvington, NY) for power grip and by a pinch strength dynamometer for tip pinch strength, tripod grip, and key pinch strength. A within-subject research design was used in this prospective study. Each subject served as the control by preinjection measurements of grip and pinch strength. Subsequent measurements after ulnar nerve block were used to examine within-subject change. In power grip, there was a significant reduction of maximum grip force of 26.9% with ulnar nerve block compared with grip force without block (P force could be confirmed. However, the assessment of other dimensions of hand strength as tip pinch, tripod pinch and key pinch had more relevance in demonstrating hand strength changes resulting from an distal ulnar nerve lesion. The measurement of tip pinch, tripod grip and key pinch can improve the follow-up in hand rehabilitation. II. Copyright © 2017 Hanley & Belfus. Published by Elsevier Inc. All rights reserved.

  6. The Effects of Industrial Protective Gloves and Hand Skin Temperatures on Hand Grip Strength and Discomfort Rating

    Directory of Open Access Journals (Sweden)

    Mohamed Z. Ramadan

    2017-12-01

    Full Text Available Daily working activities and functions require a high contribution of hand and forearm muscles in executing grip force. To study the effects of wearing different gloves on grip strength, under a variety of hand skin temperatures, an assessment of the maximum grip strength was performed with 32 healthy male workers with a mean age (standard deviation of 30.44 (5.35 years wearing five industrial gloves at three hand skin temperatures. Their ages and anthropometric characteristics including body mass index (BMI, hand length, hand width, hand depth, hand palm, and wrist circumference were measured. The hand was exposed to different bath temperatures (5 °C, 25 °C, and 45 °C and hand grip strength was measured using a Jamar hydraulic hand dynamometer with and without wearing the gloves (chemical protection glove, rubber insulating glove, anti-vibration impact glove, cotton yarn knitted glove, and RY-WG002 working glove. The data were analyzed using the Shapiro–Wilk test, Pearson correlation coefficient, Tukey test, and analysis of variance (ANOVA of the within-subject design analysis. The results showed that wearing gloves significantly affected the maximum grip strength. Wearing the RY-WG002 working glove produced a greater reduction on the maximum grip when compared with the bare hand, while low temperatures (5 °C had a significant influence on grip when compared to medium (25 °C and high (45 °C hand skin temperatures. In addition, participants felt more discomfort in both environmental extreme conditions. Furthermore, they reported more discomfort while wearing neoprene, rubber, and RY-WG002 working gloves.

  7. The Effects of Industrial Protective Gloves and Hand Skin Temperatures on Hand Grip Strength and Discomfort Rating.

    Science.gov (United States)

    Ramadan, Mohamed Z

    2017-12-04

    Daily working activities and functions require a high contribution of hand and forearm muscles in executing grip force. To study the effects of wearing different gloves on grip strength, under a variety of hand skin temperatures, an assessment of the maximum grip strength was performed with 32 healthy male workers with a mean age (standard deviation) of 30.44 (5.35) years wearing five industrial gloves at three hand skin temperatures. Their ages and anthropometric characteristics including body mass index (BMI), hand length, hand width, hand depth, hand palm, and wrist circumference were measured. The hand was exposed to different bath temperatures (5 °C, 25 °C, and 45 °C) and hand grip strength was measured using a Jamar hydraulic hand dynamometer with and without wearing the gloves (chemical protection glove, rubber insulating glove, anti-vibration impact glove, cotton yarn knitted glove, and RY-WG002 working glove). The data were analyzed using the Shapiro-Wilk test, Pearson correlation coefficient, Tukey test, and analysis of variance (ANOVA) of the within-subject design analysis. The results showed that wearing gloves significantly affected the maximum grip strength. Wearing the RY-WG002 working glove produced a greater reduction on the maximum grip when compared with the bare hand, while low temperatures (5 °C) had a significant influence on grip when compared to medium (25 °C) and high (45 °C) hand skin temperatures. In addition, participants felt more discomfort in both environmental extreme conditions. Furthermore, they reported more discomfort while wearing neoprene, rubber, and RY-WG002 working gloves.

  8. Tightening grip

    Science.gov (United States)

    Strukov, Dmitri B.

    2018-01-01

    Engineering channels for ion transport in a SiGe solid-state electrolyte layer allows one to significantly decrease the spatial and temporal variations of the electrical characteristics in resistive switching memories.

  9. Effects of Anodal Transcranial Direct Current Stimulation on Visually Guided Learning of Grip Force Control

    Directory of Open Access Journals (Sweden)

    Tamas Minarik

    2015-03-01

    Full Text Available Anodal transcranial Direct Current Stimulation (tDCS has been shown to be an effective non-invasive brain stimulation method for improving cognitive and motor functioning in patients with neurological deficits. tDCS over motor cortex (M1, for instance, facilitates motor learning in stroke patients. However, the literature on anodal tDCS effects on motor learning in healthy participants is inconclusive, and the effects of tDCS on visuo-motor integration are not well understood. In the present study we examined whether tDCS over the contralateral motor cortex enhances learning of grip-force output in a visually guided feedback task in young and neurologically healthy volunteers. Twenty minutes of 1 mA anodal tDCS were applied over the primary motor cortex (M1 contralateral to the dominant (right hand, during the first half of a 40 min power-grip task. This task required the control of a visual signal by modulating the strength of the power-grip for six seconds per trial. Each participant completed a two-session sham-controlled crossover protocol. The stimulation conditions were counterbalanced across participants and the sessions were one week apart. Performance measures comprised time-on-target and target-deviation, and were calculated for the periods of stimulation (or sham and during the afterphase respectively. Statistical analyses revealed significant performance improvements over the stimulation and the afterphase, but this learning effect was not modulated by tDCS condition. This suggests that the form of visuomotor learning taking place in the present task was not sensitive to neurostimulation. These null effects, together with similar reports for other types of motor tasks, lead to the proposition that tDCS facilitation of motor learning might be restricted to cases or situations where the motor system is challenged, such as motor deficits, advanced age, or very high task demand.

  10. Television Viewing, Walking Speed, and Grip Strength in a Prospective Cohort Study

    Science.gov (United States)

    KEEVIL, VICTORIA L.; WIJNDAELE, KATRIEN; LUBEN, ROBERT; SAYER, AVAN A.; WAREHAM, NICHOLAS J.; KHAW, KAY-TEE

    2015-01-01

    ABSTRACT Purpose Television (TV) watching is the most prevalent sedentary leisure time activity in the United Kingdom. We examined associations between TV viewing time, measured over 10 yr, and two objective measures of physical capability, usual walking speed (UWS) and grip strength. Methods Community-based participants (n = 8623; 48–92 yr old) enrolled in the European Prospective Investigation of Cancer—Norfolk study attended a third health examination (3HC, 2006–2011) for measurement of maximum grip strength (Smedley dynamometer) and UWS. TV viewing time was estimated using a validated questionnaire (n = 6086) administered during two periods (3HC, 2006–2007; 2HC, 1998–2000). Associations between physical capability and TV viewing time category (<2, 2 < 3, 3 < 4, and ≥4 h·d−1) at the 3HC, 2HC, and using an average of the two measures were explored. Sex-stratified analyses were adjusted for age, physical activity, anthropometry, wealth, comorbidity, smoking, and alcohol intake and combined if no sex–TV viewing time interactions were identified. Results Men and women who watched the least TV at the 2HC or 3HC walked at a faster usual pace than those who watched the most TV. There was no evidence of effect modification by sex (Pinteraction = 0.09), and in combined analyses, participants who watched for <2 h·d−1 on average walked 4.29 cm·s−1 (95% confidence interval, 2.56–6.03) faster than those who watched for ≥4 h·d−1, with evidence of a dose–response association (Ptrend < 0.001). However, no strong associations with grip strength were found. Conclusions TV viewing time predicted UWS in older adults. More research is needed to inform public health policy and prospective associations between other measures of sedentariness, such as total sitting time or objectively measured sedentary time, and physical capability should be explored. PMID:25785826

  11. Characterization of the spontaneous and gripping-induced immobility episodes on taiep rats.

    Science.gov (United States)

    Cortés, Ma Del Carmen; Gavito, Berenice; Ita, Martha L; Valencia, Jaime; Eguibar, José R

    2005-11-01

    In 1989, we described a new autosomic-recessive myelin-mutant rat that develops a progressive motor syndrome characterized by tremor, ataxia, immobility episodes (IEs), epilepsy, and paralysis. taiep is the acronym of these symptoms. The rat developed a hypomyelination, followed by demyelination. At an age of 7-8 months, taiep rats developed IEs, characterized electroencephalographically by REM sleep-like cortical activity. In our study, we analyzed the ontogeny of gripping-induced IEs between 5 and 18 months, their dependence to light-dark changes, sexual dimorphism, and susceptibility to mild stress. Our results showed that IEs start at an age of 6.5 months, with a peak frequency between 8.5 and 9.5 months. IEs have two peaks, one in the morning (0800-1000 h) and a second peak in the middle of the night (2300-0100 h). Spontaneous IEs showed an even distribution with a mean of 3 IEs every 2 h. IEs are sexually dimorphic being more common in male rats. The IEs can be induced by gripping the rat by the tail or the thorax, but most of the IEs were produced by gripping the tail. Mild stress produced by i.p. injection of physiological saline significantly decreased IEs. These results suggested that IEs are dependent on several biological variables, which are caused by hypomyelination, followed by demyelization, which causes alterations in the brainstem and hypothalamic mechanisms responsible for the sleep-wake cycle regulation, producing emergence of REM sleep-like behavior during awake periods. (c) 2005 Wiley-Liss, Inc.

  12. Relationships between Mechanical Variables in the Traditional and Close-Grip Bench Press

    Directory of Open Access Journals (Sweden)

    Lockie Robert G.

    2017-12-01

    Full Text Available The study aim was to determine relationships between mechanical variables in the one-repetition maximum (1RM traditional bench press (TBP and close-grip bench press (CGBP. Twenty resistance-trained men completed a TBP and CGBP 1RM. The TBP was performed with the preferred grip; the CGBP with a grip width of 95% biacromial distance. A linear position transducer measured: lift distance and duration; work; and peak and mean power, velocity, and force. Paired samples t-tests (p < 0.05 compared the 1RM and mechanical variables for the TBP and CGBP; effect sizes (d were also calculated. Pearson’s correlations (r; p < 0.05 computed relationships between the TBP and CGBP. 1RM, lift duration, and mean force were greater in the TBP (d = 0.30-3.20. Peak power and velocity was greater for the CGBP (d = 0.50-1.29. The 1RM TBP correlated with CGBP 1RM, power, and force (r = 0.685-0.982. TBP work correlated with CGBP 1RM, lift distance, power, force, and work (r = 0.542-0.931. TBP power correlated with CGBP 1RM, power, force, velocity, and work (r = 0.484-0.704. TBP peak and mean force related to CGBP 1RM, power, and force (r = 0.596-0.980. Due to relationships between the load, work, power, and force for the TBP and CGBP, the CGBP could provide similar strength adaptations to the TBP with long-term use. The velocity profile for the CGBP was different to that of the TBP. The CGBP could be used specifically to improve high-velocity, upper-body pushing movements.

  13. Gloss, colour and grip: multifunctional epidermal cell shapes in bee- and bird-pollinated flowers.

    Science.gov (United States)

    Papiorek, Sarah; Junker, Robert R; Lunau, Klaus

    2014-01-01

    Flowers bear the function of filters supporting the attraction of pollinators as well as the deterrence of floral antagonists. The effect of epidermal cell shape on the visual display and tactile properties of flowers has been evaluated only recently. In this study we quantitatively measured epidermal cell shape, gloss and spectral reflectance of flowers pollinated by either bees or birds testing three hypotheses: The first two hypotheses imply that bee-pollinated flowers might benefit from rough surfaces on visually-active parts produced by conical epidermal cells, as they may enhance the colour signal of flowers as well as the grip on flowers for bees. In contrast, bird-pollinated flowers might benefit from flat surfaces produced by flat epidermal cells, by avoiding frequent visitation from non-pollinating bees due to a reduced colour signal, as birds do not rely on specific colour parameters while foraging. Moreover, flat petal surfaces in bird-pollinated flowers may hamper grip for bees that do not touch anthers and stigmas while consuming nectar and thus, are considered as nectar thieves. Beside this, the third hypothesis implies that those flower parts which are vulnerable to nectar robbing of bee- as well as bird-pollinated flowers benefit from flat epidermal cells, hampering grip for nectar robbing bees. Our comparative data show in fact that conical epidermal cells are restricted to visually-active parts of bee-pollinated flowers, whereas robbing-sensitive parts of bee-pollinated as well as the entire floral surface of bird-pollinated flowers possess on average flat epidermal cells. However, direct correlations between epidermal cell shape and colour parameters have not been found. Our results together with published experimental studies show that epidermal cell shape as a largely neglected flower trait might act as an important feature in pollinator attraction and avoidance of antagonists, and thus may contribute to the partitioning of flower-visitors.

  14. Gloss, colour and grip: multifunctional epidermal cell shapes in bee- and bird-pollinated flowers.

    Directory of Open Access Journals (Sweden)

    Sarah Papiorek

    Full Text Available Flowers bear the function of filters supporting the attraction of pollinators as well as the deterrence of floral antagonists. The effect of epidermal cell shape on the visual display and tactile properties of flowers has been evaluated only recently. In this study we quantitatively measured epidermal cell shape, gloss and spectral reflectance of flowers pollinated by either bees or birds testing three hypotheses: The first two hypotheses imply that bee-pollinated flowers might benefit from rough surfaces on visually-active parts produced by conical epidermal cells, as they may enhance the colour signal of flowers as well as the grip on flowers for bees. In contrast, bird-pollinated flowers might benefit from flat surfaces produced by flat epidermal cells, by avoiding frequent visitation from non-pollinating bees due to a reduced colour signal, as birds do not rely on specific colour parameters while foraging. Moreover, flat petal surfaces in bird-pollinated flowers may hamper grip for bees that do not touch anthers and stigmas while consuming nectar and thus, are considered as nectar thieves. Beside this, the third hypothesis implies that those flower parts which are vulnerable to nectar robbing of bee- as well as bird-pollinated flowers benefit from flat epidermal cells, hampering grip for nectar robbing bees. Our comparative data show in fact that conical epidermal cells are restricted to visually-active parts of bee-pollinated flowers, whereas robbing-sensitive parts of bee-pollinated as well as the entire floral surface of bird-pollinated flowers possess on average flat epidermal cells. However, direct correlations between epidermal cell shape and colour parameters have not been found. Our results together with published experimental studies show that epidermal cell shape as a largely neglected flower trait might act as an important feature in pollinator attraction and avoidance of antagonists, and thus may contribute to the partitioning of

  15. Fitts’ Law in the Control of Isometric Grip Force With Naturalistic Targets

    Directory of Open Access Journals (Sweden)

    Zachary C. Thumser

    2018-04-01

    Full Text Available Fitts’ law models the relationship between amplitude, precision, and speed of rapid movements. It is widely used to quantify performance in pointing tasks, study human-computer interaction, and generally to understand perceptual-motor information processes, including research to model performance in isometric force production tasks. Applying Fitts’ law to an isometric grip force task would allow for quantifying grasp performance in rehabilitative medicine and may aid research on prosthetic control and design. We examined whether Fitts’ law would hold when participants attempted to accurately produce their intended force output while grasping a manipulandum when presented with images of various everyday objects (we termed this the implicit task. Although our main interest was the implicit task, to benchmark it and establish validity, we examined performance against a more standard visual feedback condition via a digital force-feedback meter on a video monitor (explicit task. Next, we progressed from visual force feedback with force meter targets to the same targets without visual force feedback (operating largely on feedforward control with tactile feedback. This provided an opportunity to see if Fitts’ law would hold without vision, and allowed us to progress toward the more naturalistic implicit task (which does not include visual feedback. Finally, we changed the nature of the targets from requiring explicit force values presented as arrows on a force-feedback meter (explicit targets to the more naturalistic and intuitive target forces implied by images of objects (implicit targets. With visual force feedback the relation between task difficulty and the time to produce the target grip force was predicted by Fitts’ law (average r2 = 0.82. Without vision, average grip force scaled accurately although force variability was insensitive to the target presented. In contrast, images of everyday objects generated more reliable grip forces

  16. Fitts' Law in the Control of Isometric Grip Force With Naturalistic Targets.

    Science.gov (United States)

    Thumser, Zachary C; Slifkin, Andrew B; Beckler, Dylan T; Marasco, Paul D

    2018-01-01

    Fitts' law models the relationship between amplitude, precision, and speed of rapid movements. It is widely used to quantify performance in pointing tasks, study human-computer interaction, and generally to understand perceptual-motor information processes, including research to model performance in isometric force production tasks. Applying Fitts' law to an isometric grip force task would allow for quantifying grasp performance in rehabilitative medicine and may aid research on prosthetic control and design. We examined whether Fitts' law would hold when participants attempted to accurately produce their intended force output while grasping a manipulandum when presented with images of various everyday objects (we termed this the implicit task). Although our main interest was the implicit task, to benchmark it and establish validity, we examined performance against a more standard visual feedback condition via a digital force-feedback meter on a video monitor (explicit task). Next, we progressed from visual force feedback with force meter targets to the same targets without visual force feedback (operating largely on feedforward control with tactile feedback). This provided an opportunity to see if Fitts' law would hold without vision, and allowed us to progress toward the more naturalistic implicit task (which does not include visual feedback). Finally, we changed the nature of the targets from requiring explicit force values presented as arrows on a force-feedback meter (explicit targets) to the more naturalistic and intuitive target forces implied by images of objects (implicit targets). With visual force feedback the relation between task difficulty and the time to produce the target grip force was predicted by Fitts' law (average r 2 = 0.82). Without vision, average grip force scaled accurately although force variability was insensitive to the target presented. In contrast, images of everyday objects generated more reliable grip forces without the visualized

  17. Phalanx force magnitude and trajectory deviation increased during power grip with an increased coefficient of friction at the hand-object interface.

    Science.gov (United States)

    Enders, Leah R; Seo, Na Jin

    2011-05-17

    This study examined the effect of friction between the hand and grip surface on a person's grip strategy and force generation capacity. Twelve young healthy adults performed power grip exertions on an instrumented vertical cylinder with the maximum and 50% of maximum efforts (far above the grip force required to hold the cylinder), while normal and shear forces at each phalanx of all five fingers in the direction orthogonal to the gravity were recorded. The cylinder surface was varied for high-friction rubber and low-friction paper coverings. An increase in surface friction by replacing the paper covering with the rubber covering resulted in 4% greater mean phalanx normal force (perpendicular to the cylinder surface) and 22% greater mean phalanx shear force in either the proximal or distal direction of the digits (pfriction with the rubber surface compared to the paper surface was associated with a 20% increase in the angular deviation of the phalanx force from the direction normal to the cylinder surface (p<0.05). This study demonstrates that people significantly changed the magnitude and direction of phalanx forces depending on the surface they gripped. Such change in the grip strategy appears to help increase grip force generation capacity. This finding suggests that a seemingly simple power grip exertion involves sensory feedback-based motor control, and that people's power grip capacity may be reduced in cases of numbness, glove use, or injuries resulting in reduced sensation. Copyright © 2011 Elsevier Ltd. All rights reserved.

  18. Initial Effect of Taping Technique on Wrist Extension and Grip Strength and Pain of Individuals with Lateral Epicondylitis

    Directory of Open Access Journals (Sweden)

    Alireza Shamsoddini

    2010-04-01

    Full Text Available Objectives: Aim of this study is to investigate the initial effect of taping technique on wrist extension and grip strength and pain of Individuals with tennis elbow. Methods: fifteen patients (10 men and 5 women with 42.53 years on their dominant arm participated in this study. Outcome measures were wrist extension and grip strength and pain taken before and immediately after application of tape. The unaffected arm served as a control. Used of hand-held dynamometer and jammar dynamometer for evaluated of wrist extension and grip strength. Also, visual analog scale (VAS used for evaluated of pain Results: Among the variables, significant differences were found in wrist extension strength between effected and unaffected arm (P=0.006. Also, changes in grip strength shows statically significant improve in effect arm than unaffected arm (P=0.001. Changes in pain in impaired arm were positive. Discussion: Taping technique, as applied in this study demonstrated an impressive effect on wrist extension and grip strength and pain in individuals with tennis elbow. Therefore, it is recommended that this method may be useful in the management of this condition during exercise and functional rehabilitation.

  19. Associations between aging-related changes in grip strength and cognitive function in older adults: A systematic review.

    Science.gov (United States)

    Zammit, Andrea R; Robitaille, Annie; Piccinin, Andrea; Muniz-Terrera, Graciela; Hofer, Scott M

    2018-03-08

    Grip strength and cognitive function reflect upper body muscle strength and mental capacities. Cross-sectional research has suggested that in old age these two processes are moderately to highly associated, and that an underlying common cause drives this association. Our aim was to synthesize and evaluate longitudinal research addressing whether changes in grip strength are associated with changes in cognitive function in healthy older adults. We systematically reviewed English-language research investigating the longitudinal association between repeated measures of grip strength and of cognitive function in community-dwelling older adults to evaluate the extent to which the two indices decline concurrently. We used four search engines: Embase, PsychINFO, PubMed, and Web of Science. Of 459 unique citations, 6 met our full criteria: 4 studies reported a longitudinal association between rates of change in grip strength and cognitive function in older adults, 2 of which reported the magnitudes of these associations as ranging from low to moderate; 2 studies reported significant cross-sectional but not longitudinal associations among rates of change. All studies concluded that cognitive function and grip strength declined, on average, with increasing age, although with little to no evidence for longitudinal associations among rates of change. Future research is urged to expand the study of physical and cognitive associations in old age using a within-person and multi-study integrative approach to evaluate the reliability of longitudinal results with greater emphasis on the magnitude of this association.

  20. Grip Strength as an Indicator of Health-Related Quality of Life in Old Age-A Pilot Study.

    Science.gov (United States)

    Musalek, Christina; Kirchengast, Sylvia

    2017-11-24

    Over the last century life expectancy has increased dramatically nearly all over the world. This dramatic absolute and relative increase of the old aged people component of the population has influenced not only population structure but also has dramatic implications for the individuals and public health services. The aim of the present pilot study was to examine the impact of physical well-being assessed by hand grip strength and social factors estimated by social contact frequency on health-related quality of life among 22 men and 41 women ranging in age between 60 and 94 years. Physical well-being was estimated by hand grip strength, data concerning subjective wellbeing and health related quality of life were collected by personal interviews based on the WHOQOL-BREF questionnaires. Number of offspring and intergenerational contacts were not related significantly to health-related quality of life, while social contacts with non-relatives and hand grip strength in contrast had a significant positive impact on health related quality of life among old aged men and women. Physical well-being and in particular muscle strength-estimated by grip strength-may increase health-related quality of life and is therefore an important source for well-being during old age. Grip strength may be used as an indicator of health-related quality of life.

  1. A novel mechanism of hippocampal LTD involving muscarinic receptor-triggered interactions between AMPARs, GRIP and liprin-α

    Directory of Open Access Journals (Sweden)

    Dickinson Bryony A

    2009-06-01

    Full Text Available Abstract Background Long-term depression (LTD in the hippocampus can be induced by activation of different types of G-protein coupled receptors, in particular metabotropic glutamate receptors (mGluRs and muscarinic acethycholine receptors (mAChRs. Since mGluRs and mAChRs activate the same G-proteins and isoforms of phospholipase C (PLC, it would be expected that these two forms of LTD utilise the same molecular mechanisms. However, we find a distinct mechanism of LTD involving GRIP and liprin-α. Results Whilst both forms of LTD require activation of tyrosine phosphatases and involve internalisation of AMPARs, they use different molecular interactions. Specifically, mAChR-LTD, but not mGluR-LTD, is blocked by peptides that inhibit the binding of GRIP to the AMPA receptor subunit GluA2 and the binding of GRIP to liprin-α. Thus, different receptors that utilise the same G-proteins can regulate AMPAR trafficking and synaptic efficacy via distinct molecular mechanisms. Conclusion Our results suggest that mAChR-LTD selectively involves interactions between GRIP and liprin-α. These data indicate a novel mechanism of synaptic plasticity in which activation of M1 receptors results in AMPAR endocytosis, via a mechanism involving interactions between GluA2, GRIP and liprin-α.

  2. Comparison of Initial Effect of Taping Techniqe and Counterforce Brace on Pain and Grip Strength of Patients with Lateral Epicondylitis

    Directory of Open Access Journals (Sweden)

    Ali Reza Shamsoddini

    2006-04-01

    Full Text Available Objective: In patients with lateral epicondylitis present of pain and decrease of grip strength are essential problems. Use of splint have major rule in treatment these patients that causes relief of pain and increase of grip strength. Both taping technique and counterforce brace are two methods of treatments of lateral epicondylitis patients but we were not sure which method could be more useful and Answer of this question is magor aim of this study. Materials & Methods: This study is a Quasi experimental. We selected 30 patients between 30-55 years conveniently and divided them in two groups simple randomized.  Results: In grip strength test, the average difference between two methods was t = 1/92 which showed there is not significant. So, there isn't any difference between two methods on grip strength. In assessment of pain, we tested patients in two positions: first patient's hand was in comfort position, second in which when wrist of hand was in extension position. In both of position, that average difference between two methods (first t = 3/78 and secondary t = 3/2 found to be significant. Choose of method in such treatment is considered to be important. Conclusion: taping technique is more effective than counterforce brace to relief of pain of patients with lateral epicondylitis, but in grip strength no difference between two methods.

  3. The brain adjusts grip forces differently according to gravity and inertia: a parabolic flight experiment

    Science.gov (United States)

    White, Olivier

    2015-01-01

    In everyday life, one of the most frequent activities involves accelerating and decelerating an object held in precision grip. In many contexts, humans scale and synchronize their grip force (GF), normal to the finger/object contact, in anticipation of the expected tangential load force (LF), resulting from the combination of the gravitational and the inertial forces. In many contexts, GF and LF are linearly coupled. A few studies have examined how we adjust the parameters–gain and offset–of this linear relationship. However, the question remains open as to how the brain adjusts GF regardless of whether LF is generated by different combinations of weight and inertia. Here, we designed conditions to generate equivalent magnitudes of LF by independently varying mass and movement frequency. In a control experiment, we directly manipulated gravity in parabolic flights, while other factors remained constant. We show with a simple computational approach that, to adjust GF, the brain is sensitive to how LFs are produced at the fingertips. This provides clear evidence that the analysis of the origin of LF is performed centrally, and not only at the periphery. PMID:25717293

  4. Gripping characteristics of an electromagnetically activated magnetorheological fluid-based gripper

    Science.gov (United States)

    Choi, Young T.; Hartzell, Christine M.; Leps, Thomas; Wereley, Norman M.

    2018-05-01

    The design and test of a magnetorheological fluid (MRF)-based universal gripper (MR gripper) are presented in this study. The MR gripper was developed to have a simple design, but with the ability to produce reliable gripping and handling of a wide range of simple objects. The MR gripper design consists of a bladder mounted atop an electromagnet, where the bladder is filled with an MRF, which was formulated to have long-term stable sedimentation stability, that was synthesized using a high viscosity linear polysiloxane (HVLP) carrier fluid with a carbonyl iron particle (CIP) volume fraction of 35%. Two bladders were fabricated: a magnetizable bladder using a magnetorheological elastomer (MRE), and a passive (non-magnetizable) silicone rubber bladder. The holding force and applied (initial compression) force of the MR gripper for a bladder fill volume of 75% were experimentally measured, for both magnetizable and passive bladders, using a servohydraulic material testing machine for a range of objects. The gripping performance of the MR gripper using an MRE bladder was compared to that of the MR gripper using a passive bladder.

  5. Development of Hand Grip Assistive Device Control System for Old People through Electromyography (EMG Signal Acquisitions

    Directory of Open Access Journals (Sweden)

    Khamis Herman

    2017-01-01

    Full Text Available The hand grip assistive device is a glove to assist old people who suffer from hand weakness in their daily life activities. The device earlier control system only use simple on and off switch. This required old people to use both hand to activate the device. The new control system of the hand grip assistive device was developed to allow single hand operation for old people. New control system take advantages of electromyography (EMG and flex sensor which was implemented to the device. It was programmed into active and semi-active mode operation. EMG sensors were placed on the forearm to capture EMG signal of Flexor Digitorum Profundus muscle to activate the device. Flex sensor was used to indicate the finger position and placed on top of the finger. The signal from both sensors then used to control the device. The new control system allowed single hand operation and designed to prevent user from over depended on the device by activating it through moving their fingers.

  6. Hurricane Imaging Radiometer Wind Speed and Rain Rate Retrievals during the 2010 GRIP Flight Experiment

    Science.gov (United States)

    Sahawneh, Saleem; Farrar, Spencer; Johnson, James; Jones, W. Linwood; Roberts, Jason; Biswas, Sayak; Cecil, Daniel

    2014-01-01

    Microwave remote sensing observations of hurricanes, from NOAA and USAF hurricane surveillance aircraft, provide vital data for hurricane research and operations, for forecasting the intensity and track of tropical storms. The current operational standard for hurricane wind speed and rain rate measurements is the Stepped Frequency Microwave Radiometer (SFMR), which is a nadir viewing passive microwave airborne remote sensor. The Hurricane Imaging Radiometer, HIRAD, will extend the nadir viewing SFMR capability to provide wide swath images of wind speed and rain rate, while flying on a high altitude aircraft. HIRAD was first flown in the Genesis and Rapid Intensification Processes, GRIP, NASA hurricane field experiment in 2010. This paper reports on geophysical retrieval results and provides hurricane images from GRIP flights. An overview of the HIRAD instrument and the radiative transfer theory based, wind speed/rain rate retrieval algorithm is included. Results are presented for hurricane wind speed and rain rate for Earl and Karl, with comparison to collocated SFMR retrievals and WP3D Fuselage Radar images for validation purposes.

  7. Effect of skin hydration on the dynamics of fingertip gripping contact.

    Science.gov (United States)

    André, T; Lévesque, V; Hayward, V; Lefèvre, P; Thonnard, J-L

    2011-11-07

    The dynamics of fingertip contact manifest themselves in the complex skin movements observed during the transition from a stuck state to a fully developed slip. While investigating this transition, we found that it depended on skin hydration. To quantify this dependency, we asked subjects to slide their index fingertip on a glass surface while keeping the normal component of the interaction force constant with the help of visual feedback. Skin deformation inside the contact region was imaged with an optical apparatus that allowed us to quantify the relative sizes of the slipping and sticking regions. The ratio of the stuck skin area to the total contact area decreased linearly from 1 to 0 when the tangential force component increased from 0 to a maximum. The slope of this relationship was inversely correlated to the normal force component. The skin hydration level dramatically affected the dynamics of the contact encapsulated in the course of evolution from sticking to slipping. The specific effect was to reduce the tendency of a contact to slip, regardless of the variations of the coefficient of friction. Since grips were more unstable under dry skin conditions, our results suggest that the nervous system responds to dry skin by exaggerated grip forces that cannot be simply explained by a change in the coefficient of friction.

  8. Muscular forearm activation in hand-grip tasks with superimposition of mechanical vibrations.

    Science.gov (United States)

    Fattorini, L; Tirabasso, A; Lunghi, A; Di Giovanni, R; Sacco, F; Marchetti, E

    2016-02-01

    The purpose of this paper is to evaluate the muscular activation of the forearm, with or without vibration stimuli at different frequencies while performing a grip tasks of 45s at various level of exerted force. In 16 individuals, 9 females and 7 males, the surface electromyogram (EMG) of extensor carpi radialis longus and the flexor carpi ulnari muscles were assessed. At a short latency from onset EMG, RMS and the level of MU synchronization were assessed to evaluate the muscular adaptations. Whilst a trend of decay of EMG Median frequency (MDFd) was employed as an index of muscular fatigue. Muscular tasks consists of the grip of an instrumented handle at a force level of 20%, 30%, 40%, 60% of the maximum voluntary force. Vibration was supplied by a shaker to the hand in mono-frequential waves at 20, 30, 33 and 40Hz. In relation to EMG, RMS and MU synchronization, the muscular activation does not seem to change with the superimposition of the mechanical vibrations, on the contrary a lower MDFd was observed at 33Hz than in absence of vibration. This suggests an early muscular fatigue induced by vibration due to the fact that 33Hz is a resonance frequency for the hand-arm system. Copyright © 2015 Elsevier Ltd. All rights reserved.

  9. Modified forelimb grip strength test detects aging-associated physiological decline in skeletal muscle function in male mice.

    Science.gov (United States)

    Takeshita, Hikari; Yamamoto, Koichi; Nozato, Satoko; Inagaki, Tadakatsu; Tsuchimochi, Hirotsugu; Shirai, Mikiyasu; Yamamoto, Ryohei; Imaizumi, Yuki; Hongyo, Kazuhiro; Yokoyama, Serina; Takeda, Masao; Oguro, Ryosuke; Takami, Yoichi; Itoh, Norihisa; Takeya, Yasushi; Sugimoto, Ken; Fukada, So-Ichiro; Rakugi, Hiromi

    2017-02-08

    The conventional forelimb grip strength test is a widely used method to assess skeletal muscle function in rodents; in this study, we modified this method to improve its variability and consistency. The modified test had lower variability among trials and days than the conventional test in young C57BL6 mice, especially by improving the variabilities in male. The modified test was more sensitive than the conventional test to detect a difference in motor function between female and male mice, or between young and old male mice. When the modified test was performed on male mice during the aging process, reduction of grip strength manifested between 18 and 24 months of age at the group level and at the individual level. The modified test was similar to the conventional test in detecting skeletal muscle dysfunction in young male dystrophic mice. Thus, the modified forelimb grip strength test, with its improved validity and reliability may be an ideal substitute for the conventional method.

  10. TEST-RETEST RELIABILITY OF HAND GRIP STRENGTH MEASUREMENT USING A JAMAR HAND DYNAMOMETER IN PATIENTS WITH ACUTE AND CHRONIC CERVICAL RADICULOPATHY

    Directory of Open Access Journals (Sweden)

    Ejazi G

    2017-12-01

    Full Text Available Background: To evaluate the test-retest reliability of Jamar hand held dynamometer for measuring handgrip strength (HGS in patients with acute and chronic cervical radiculopathy and to find out the difference in measurement of the handgrip strength between acute and chronic cervical radiculopathy. Methods: A prospective, observational and non-experimental, the comparative study design was used. A sample of 72 subjects (37 women and 35 men suffering from cervical radiculopathy were divided into two groups i.e., Group A(acute and Group B(chronic, handgrip strength was measured using Jamar hand held dynamometer on two occasions by the same rater with an interval of 7-days. Data collection was based on standard guidelines of American Society of Hand Therapists. Three gripping trials (measured in Kg with patient’s arm in standardized arm position were recorded. The data was analyzed from the mean score obtained from the sample. Result: One-way Analysis of Variance(ANOVA was used to evaluate test-retest reliability and Tukey-Kramer Multiple Comparison Test used to find the difference between handgrip strength among acute and chronic Cervical radiculopathy cases. Greater P-value (>0.05 in both testing session, as well as 95% of the confidence interval, shows the reliability of the instrument and lesser p-value (0.05 in female subjects shows no significant difference in handgrip strength between the two groups. Conclusion: Excellent test-retest reliability for hand grip strength measurement was measured in patients with acute and chronic cervical radiculopathy shows that the equipment could be used as an assessment tool for this patient and significant difference exists among male handgrip strength between acute and chronic cervical radiculopathy cases whereas no difference exists among female handgrip strength between acute and chronic cervical radiculopathy cases.

  11. Normative static grip strength of population of Turkey, effects of various factors and a comparison with international norms.

    Science.gov (United States)

    Ekşioğlu, Mahmut

    2016-01-01

    Normative data are of importance in ergonomics and clinical settings. Applying normative data internationally is questionable. To this end, this study aimed to establish gender- and age-specific reference values for static (isometric) hand grip strength of normal population of Turkey with special regard to occupational demand, and compare them with the international norms. The secondary aims were to investigate the effects of gender, age-group, weight-group, job-group, hand and several anthropometric variables on static grip strength. A sample of 211 (128 male and 83 female) volunteers aged between 18 and 69 with various occupations participated in the study. Grip strength data were collected using a Jamar dynamometer with standard testing position, protocol and instructions. The mean and std deviation of maximum voluntary static grip strength values (in N) for dominant and non-dominant hands respectively were 455.2 ± 73.6 and 441.5 ± 72.6 for males, and 258 ± 46.1 and 246.2 ± 49.1 for females. The mean female strength was about 57% of the mean male strength value for both dominant and non-dominant hands. There was a curvilinear relationship of grip strength to age, significant differences between genders, hands, and some age-groups, and a correlation to height, body-mass, BMI and hand dimensions depending on the gender. The comparisons with the norms of other world populations indicate that there are cross-national grip strength variations among some nations but not all. Copyright © 2015 Elsevier Ltd and The Ergonomics Society. All rights reserved.

  12. GRIP: A web-based system for constructing Gold Standard datasets for protein-protein interaction prediction

    Directory of Open Access Journals (Sweden)

    Zheng Huiru

    2009-01-01

    Full Text Available Abstract Background Information about protein interaction networks is fundamental to understanding protein function and cellular processes. Interaction patterns among proteins can suggest new drug targets and aid in the design of new therapeutic interventions. Efforts have been made to map interactions on a proteomic-wide scale using both experimental and computational techniques. Reference datasets that contain known interacting proteins (positive cases and non-interacting proteins (negative cases are essential to support computational prediction and validation of protein-protein interactions. Information on known interacting and non interacting proteins are usually stored within databases. Extraction of these data can be both complex and time consuming. Although, the automatic construction of reference datasets for classification is a useful resource for researchers no public resource currently exists to perform this task. Results GRIP (Gold Reference dataset constructor from Information on Protein complexes is a web-based system that provides researchers with the functionality to create reference datasets for protein-protein interaction prediction in Saccharomyces cerevisiae. Both positive and negative cases for a reference dataset can be extracted, organised and downloaded by the user. GRIP also provides an upload facility whereby users can submit proteins to determine protein complex membership. A search facility is provided where a user can search for protein complex information in Saccharomyces cerevisiae. Conclusion GRIP is developed to retrieve information on protein complex, cellular localisation, and physical and genetic interactions in Saccharomyces cerevisiae. Manual construction of reference datasets can be a time consuming process requiring programming knowledge. GRIP simplifies and speeds up this process by allowing users to automatically construct reference datasets. GRIP is free to access at http://rosalind.infj.ulst.ac.uk/GRIP/.

  13. The contribution of prenatal environment and genetic factors to the association between birth weight and adult grip strength.

    Directory of Open Access Journals (Sweden)

    Charlotte L Ridgway

    2011-03-01

    Full Text Available Low birth weight has been associated with reduced hand grip strength, which is a marker of future physical function and disease risk. The aim of this study was to apply a twin pair approach, using both 'individual' data and 'within-pair' differences, to investigate the influence of birth weight on hand grip strength and whether this association may be mediated through fat free mass (FFM. Participants from the East Flanders Prospective Twin Survey were included if born without congenital abnormalities, birth weight >500 g and ≥22 weeks of gestation. Follow up in adulthood (age: 18-34 year, included anthropometric measures and hand grip (n = 783 individuals, n = 326 same-sex twin pairs. Birth weight was positively associated with hand grip strength (β = 2.60 kg, 95% CI 1.52, 3.67, p<0.001 and FFM (β = 4.2, 95% CI 3.16, 5.24, p<0.001, adjusted for gestational age, sex and adult age. Using 'within-pair' analyses, the birth weight hand grip association was significant in DZ men only (β = 5.82, 95% CI 0.67, 10.97, p = 0.028, which was attenuated following adjustment for FFM. Within-pair birth weight FFM associations were most pronounced in DZ men (β = 11.20, 95% CI 7.18, 15.22, p<0.001. Our 'individual' analyses show that higher birth weight is associated with greater adult hand grip strength, which is mediated through greater adult FFM. The 'within-pair' analyses confirm this observation and furthermore show that, particularly in men, genetic factors may in part explain this association, as birth weight differences in DZ men result in greater differences in adult strength and FFM.

  14. Corrosion caused by elevator and spider marks on CRA pipe: Comparison of conventional inserts and a new gripping system

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1997-05-01

    Corrosion-resistant alloys (CRA) are used to reduce corrosion damage to casing and tubing strings and prolong the life span of the well pipe. An analysis of various corrosion mechanisms shows that surface integrity is an important factor in corrosion prevention. Surface damage caused by inappropriate handling or conventional slip markings contribute directly to the development and propagation of corrosion. A newly developed gripping system distributes the load equally onto a large number of small peaks, minimizing the indentation of each single peak. The new gripping system does not damage the surface integrity of the pipe, virtually eliminating the corrosion potential.

  15. Grip strength is strongly associated with height, weight and gender in childhood : a cross sectional study of 2241 children and adolescents providing reference values

    NARCIS (Netherlands)

    Ploegmakers, Joris J. W.; Hepping, Ann M.; Geertzen, Jan H. B.; Bulstra, Sjoerd K.; Stevens, Martin

    2013-01-01

    Question: What are reference values for grip strength in children and adolescents based on a large and heterogeneous study population? What is the association of grip strength with age, gender, weight, and height in this population? Design: Cross-sectional study. Participants: Participants were

  16. Does a history of physical exposures at work affect hand-grip strength in midlife?

    DEFF Research Database (Denmark)

    Møller, Anne; Reventlow, Susanne; Hansen, Åse Marie

    2013-01-01

    were non-linear and primarily positive among men. Among women, the associations were non-linear and, according to ton-years, primarily negatively associated with HGS but statistically insignificant. CONCLUSION: A history of physical exposures at work explained only a minor part of the variation in HGS......OBJECTIVE: The aim of this cohort study was to examine associations between physical exposures throughout working life and hand-grip strength (HGS) in midlife. METHODS: The Copenhagen Aging and Midlife Biobank (CAMB) provided data about employment and HGS for 3843 Danes. Individual job histories......, including duration of employment in specific jobs, were assigned exposures from a job exposure matrix. Exposures were standardized to ton-years (lifting 1000 kg each day in one year), stand-years (standing/walking for six hours each day in one year) and kneel-years (kneeling for one hour each day in one...

  17. Weight-specific anticipatory coding of grip force in human dorsal premotor cortex

    DEFF Research Database (Denmark)

    van Nuenen, Bart F L; Kuhtz-Buschbeck, Johann; Schulz, Christian

    2012-01-01

    , using either continuous theta burst stimulation (cTBS) at 80% (inhibitory cTBS) or 30% (sham cTBS) of active motor threshold. The conditioning effects of cTBS on preparatory brain activity were assessed with functional MRI, while participants lifted a light or heavy weight in response to a go-cue (S2......). An additional pre-cue (S1) correctly predicted the weight in 75% of the trials. Participants were asked to use this prior information to prepare for the lift. In the sham condition, grip force showed a consistent undershoot, if the S1 incorrectly prompted the preparation of a light lift. Likewise, an S1...... during object lifting....

  18. Grip-Pattern Verification for Smart Gun Based on Maximum-Pairwise Comparison and Mean-Template Comparison

    NARCIS (Netherlands)

    Shang, X.; Veldhuis, Raymond N.J.

    2008-01-01

    In our biometric verification system of a smart gun, the rightful user of a gun is authenticated by grip-pattern recognition. In this work verification will be done using two types of comparison methods, respectively. One is mean-template comparison, where the matching score between a test image and

  19. Constraints on grip selection in hemiparetic cerebral palsy: Effects of lesional side, end-point accuracy and context.

    NARCIS (Netherlands)

    Steenbergen, B.; Meulenbroek, R.G.J.; Rosenbaum, D.A.

    2004-01-01

    This study was concerned with the selection criteria used for grip planning in adolescents with left or right hemiparetic cerebral palsy. In the first experiment participants picked up a pencil and placed the tip in a pre-defined target region. We varied the size of the target to test the hypothesis

  20. Coefficient of friction of dry slash pine and southern red oak on three tension-grip facings

    Science.gov (United States)

    Truett J. Lemoine; Peter Koch

    1974-01-01

    A urethane material proved to have nine times higher static friction coefficient (0.9) than smooth steel (0.1) on radial and tangential wood surfaces pulled parallel to the grain. It is probably superior to 220-grit garnet paper or sand coatings for tension-grip facings in lumber testing machines.

  1. The Effect of Repetitive Rhythmic Precision Grip Task-Oriented Rehabilitation in Chronic Stroke Patients: A Pilot Study

    Science.gov (United States)

    Dispa, Delphine; Lejeune, Thierry; Thonnard, Jean-Louis

    2013-01-01

    Most chronic stroke patients present with difficulty in the manipulation of objects. The aim of this study was to test whether an intensive program of precision grip training could improve hand functioning of patients at more than 6 months after a stroke. This was a cross-over study; hence, at inclusion, the patients were randomly divided into two…

  2. The Effect of Isometric Massage on Global Grip Strength after Conservative Treatment of Distal Radial Fractures. Pilot Study.

    Science.gov (United States)

    Ratajczak, Karina; Płomiński, Janusz

    2015-01-01

    The most common fracture of the distal end of the radius is Colles' fracture. Treatment modalities available for use in hand rehabilitation after injury include massage. The aim of this study was to evaluate the effect of isometric massage on the recovery of hand function in patients with Colles fractures. For this purpose, the strength of the finger flexors was assessed as an objective criterion for the evaluation of hand function. The study involved 40 patients, randomly divided into Group A of 20 patients and Group B of 20 patients. All patients received physical therapy and exercised individually with a physiotherapist. Isometric massage was additionally used in Group A. Global grip strength was assessed using a pneumatic force meter on the first and last day of therapy. Statistical analysis was performed using STATISTICA. Statistical significance was defined as a P value of less than 0.05. In both groups, global grip strength increased significantly after the therapy. There was no statistically significant difference between the groups. The men and women in both groups equally improved grip strength. A statistically significant difference was demonstrated between younger and older patients, with younger patients achieving greater gains in global grip strength in both groups. The incorporation of isometric massage in the rehabilitation plan of patients after a distal radial fracture did not significantly contribute to faster recovery of hand function or improve their quality of life.

  3. An Overview on Gripping Force Measurement at the Micro and Nano-Scales Using Two-Fingered Microrobotic Systems

    Directory of Open Access Journals (Sweden)

    Mokrane Boudaoud

    2014-03-01

    Full Text Available Two-fingered micromanipulation systems with an integrated force sensor are widely used in robotics to sense and control gripping forces at the micro and nano-scales. They became of primary importance for an efficient manipulation and characterization of highly deformable biomaterials and nanostructures. This paper presents a chronological overview of gripping force measurement using two-fingered micromanipulation systems. The work summarizes the major achievements in this field from the early 90s to the present, focusing in particular on the evolution of measurement technologies regarding the requirements of microrobotic applications. Measuring forces below the microNewton for the manipulation of highly deformable materials, embedding force sensors within microgrippers to increase their dexterity, and reducing the influence of noise to improve the measurement resolution are among the addressed challenges. The paper shows different examples of how these challenges have been addressed. Resolution, operating range and signal/noise ratio of gripping force sensors are reported and compared. A discussion about force measurement technologies and gripping force control is performed and future trends are highlighted.

  4. Physical function, grip strength and frailty in people living with HIV in sub-Saharan Africa: systematic review.

    Science.gov (United States)

    Bernard, Charlotte; Dabis, François; de Rekeneire, Nathalie

    2017-05-01

    To present the current knowledge on physical function, grip strength and frailty in HIV-infected patients living in sub-Saharan Africa, where the phenomenon is largely underestimated. A systematic search was conducted on MEDLINE, Scopus and African Index Medicus. We reviewed articles on sub-Saharan African people living with HIV (PLHIV) >18 years old, published until November 2016. Of 537 articles, 12 were conducted in six African countries and included in this review. Five articles reported information on functional limitation and one on disability. Two of these five articles reported functional limitation (low gait speed) in PLHIV. Disability was observed in 27% and 3% of PLHIV living in rural and urban places, respectively. Two of three studies reporting grip strength reported lower grip strength (nearly 4 kg) in PLHIV in comparison with uninfected patients. One study reported that PLHIV were more likely to be frail than HIV-uninfected individuals (19.4% vs. 13.3%), whereas another reported no statistical difference. Decline in physical function, grip strength and frailty are now part of the burden of PLHIV living in SSA countries, but current data are insufficient to characterise the real public health dimension of these impairments. Further studies are needed to depict this major public health challenge. As this is likely to contribute to a significant burden on the African healthcare systems and human resources in the near future, a holistic care approach should be developed to inform guidelines. © 2017 John Wiley & Sons Ltd.

  5. EyeGrip: Detecting Targets in a Series of Uni-directional Moving Objects Using Optokinetic Nystagmus Eye Movements

    DEFF Research Database (Denmark)

    Jalaliniya, Shahram; Mardanbeigi, Diako

    2016-01-01

    computers. In this paper, we demonstrate the rich capabilities of EyeGrip with two example applications: 1) a mind reading game, and 2) a picture selection system. Our study shows that by selecting an appropriate speed and maximum number of visible images in the screen the proposed method can be used...

  6. Synaptic and functional linkages between spinal premotor interneurons and hand-muscle activity during precision grip

    Directory of Open Access Journals (Sweden)

    Tomohiko eTakei

    2013-04-01

    Full Text Available Grasping is a highly complex movement that requires the coordination of a number of hand joints and muscles. Previous studies showed that spinal premotor interneurons (PreM-INs in the primate cervical spinal cord have divergent synaptic effects on hand motoneurons and that they might contribute to hand-muscle synergies. However, the extent to which these PreM-IN synaptic connections functionally contribute to modulating hand-muscle activity is not clear. In this paper, we explored the contribution of spinal PreM-INs to hand-muscle activation by quantifying the synaptic linkage (SL and functional linkage (FL of the PreM-INs with hand-muscle activities. The activity of 23 PreM-INs was recorded from the cervical spinal cord (C6–T1, with EMG signals measured simultaneously from hand and arm muscles in two macaque monkeys performing a precision grip task. Spike-triggered averages (STAs of rectified EMGs were compiled for 456 neuron–muscle pairs; 63 pairs showed significant post-spike effects (i.e., SL. Conversely, 231 of 456 pairs showed significant cross-correlations between the IN firing rate and rectified EMG (i.e., FL. Importantly, a greater proportion of the neuron–muscle pairs with SL showed FL (43/63 pairs, 68% compared with the pairs without SL (203/393, 52%, and the presence of SL was significantly associated with that of FL. However, a significant number of pairs had SL without FL (SL∩!FL, n = 20 or FL without SL (!SL∩FL, n = 203, and the proportions of these incongruities exceeded the number expected by chance. These results suggested that spinal PreM-INs function to significantly modulate hand-muscle activity during precision grip, but the contribution of other neural structures is also needed to recruit an adequate combination of hand-muscle motoneurons.

  7. Isometric hand grip strength measured by the Nintendo Wii Balance Board - a reliable new method.

    Science.gov (United States)

    Blomkvist, A W; Andersen, S; de Bruin, E D; Jorgensen, M G

    2016-02-03

    Low hand grip strength is a strong predictor for both long-term and short-term disability and mortality. The Nintendo Wii Balance Board (WBB) is an inexpensive, portable, wide-spread instrument with the potential for multiple purposes in assessing clinically relevant measures including muscle strength. The purpose of the study was to explore intrarater reliability and concurrent validity of the WBB by comparing it to the Jamar hand dynamometer. Intra-rater test-retest cohort design with randomized validity testing on the first session. Using custom WBB software, thirty old adults (69.0 ± 4.2 years of age) were studied for reproducibility and concurrent validity compared to the Jamar hand dynamometer. Reproducibility was tested for dominant and non-dominant hands during the same time-of-day, one week apart. Intraclass correlation coefficient (ICC) and standard error of measurement (SEM) and limits of agreement (LOA) were calculated to describe relative and absolute reproducibility respectively. To describe concurrent validity, Pearson's product-moment correlation and ICC was calculated. Reproducibility was high with ICC values of >0.948 across all measures. Both SEM and LOA were low (0.2-0.5 kg and 2.7-4.2 kg, respectively) in both the dominant and non-dominant hand. For validity, Pearson correlations were high (0.80-0.88) and ICC values were fair to good (0.763-0.803). Reproducibility for WBB was high for relative measures and acceptable for absolute measures. In addition, concurrent validity between the Jamar hand dynamometer and the WBB was acceptable. Thus, the WBB may be a valid instrument to assess hand grip strength in older adults.

  8. An exploration of grip force regulation with a low-impedance myoelectric prosthesis featuring referred haptic feedback.

    Science.gov (United States)

    Brown, Jeremy D; Paek, Andrew; Syed, Mashaal; O'Malley, Marcia K; Shewokis, Patricia A; Contreras-Vidal, Jose L; Davis, Alicia J; Gillespie, R Brent

    2015-11-25

    Haptic display technologies are well suited to relay proprioceptive, force, and contact cues from a prosthetic terminal device back to the residual limb and thereby reduce reliance on visual feedback. The ease with which an amputee interprets these haptic cues, however, likely depends on whether their dynamic signal behavior corresponds to expected behaviors-behaviors consonant with a natural limb coupled to the environment. A highly geared motor in a terminal device along with the associated high back-drive impedance influences dynamic interactions with the environment, creating effects not encountered with a natural limb. Here we explore grasp and lift performance with a backdrivable (low backdrive impedance) terminal device placed under proportional myoelectric position control that features referred haptic feedback. We fabricated a back-drivable terminal device that could be used by amputees and non-amputees alike and drove aperture (or grip force, when a stiff object was in its grasp) in proportion to a myoelectric signal drawn from a single muscle site in the forearm. In randomly ordered trials, we assessed the performance of N=10 participants (7 non-amputee, 3 amputee) attempting to grasp and lift an object using the terminal device under three feedback conditions (no feedback, vibrotactile feedback, and joint torque feedback), and two object weights that were indiscernible by vision. Both non-amputee and amputee participants scaled their grip force according to the object weight. Our results showed only minor differences in grip force, grip/load force coordination, and slip as a function of sensory feedback condition, though the grip force at the point of lift-off for the heavier object was significantly greater for amputee participants in the presence of joint torque feedback. An examination of grip/load force phase plots revealed that our amputee participants used larger safety margins and demonstrated less coordination than our non-amputee participants

  9. Effect of Insoles with a Toe-Grip Bar on Toe Function and Standing Balance in Healthy Young Women: A Randomized Controlled Trial

    Directory of Open Access Journals (Sweden)

    Hideki Nakano

    2017-01-01

    Full Text Available Objective. The aim of this randomized controlled study was to investigate the effects of insoles with a toe-grip bar on toe function and standing balance in healthy young women. Methods. Thirty female subjects were randomly assigned to an intervention group or a control group. The intervention group wore shoes with insoles with a toe-grip bar. The control group wore shoes with general insoles. Both groups wore the shoes for 4 weeks, 5 times per week, 9 hours per day. Toe-grip strength, toe flexibility, static balance (total trajectory length and envelope area of the center of pressure, and dynamic balance (functional reach test were measured before and after the intervention. Results. Significant interactions were observed for toe-grip strength and toe flexibility (F=12.53, p<0.01; F=5.84, p<0.05, resp., with significant improvement in the intervention group compared with that in the control group. Post hoc comparisons revealed that both groups showed significant improvement in toe-grip strength (p<0.01 and p<0.05, resp., with higher benefits observed for the intervention group (p<0.01. Conversely, no significant interaction was observed in the total trajectory length, envelope area, and functional reach test. Conclusions. This study suggests that insoles with a toe-grip bar contribute to improvements in toe-grip strength and toe flexibility in healthy young women.

  10. Muscle response to pneumatic hand tool torque reaction forces.

    Science.gov (United States)

    Radwin, R G; VanBergeijk, E; Armstrong, T J

    1989-06-01

    Surface electromyography was used for studying the effects of torque reaction force acting against the hand, on forearm muscle activity and grip force for five subjects operating right angle, air shut-off nutrunners. Four tools having increasing spindle torque were operated using short and long torque reaction times. Nutrunner spindle torque ranged between 30 Nm and 100 Nm. Short torque reaction time was considered 0.5 s while long torque reaction time was 2 s. Peak horizontal force was the greatest component of the reaction force acting against the hand and accounted for more than 97% of the peak resultant hand force. Peak hand force increased from 89 N for the smallest tool to 202 N for the largest tool. Forearm muscle rms EMG, scaled for grip force, indicated average flexor activity during the Torque-reaction phase was more than four times greater than the Pre-start and Post Shut-off phases, and two times greater than the Run-down phase. Flexor EMG activity during the Torque-reaction phase increased for increasing tool peak spindle torque. Average flexor rms EMG activity, scaled for grip force, during the Torque-reaction phase increased from 372 N for the 30 Nm nutrunner to 449 N for the 100 Nm nutrunner. Flexor rms EMG activity averaged during the Torque-reaction phase and scaled for grip force was 390 N for long torque reaction times and increased to 440 N for short torque reaction times. Flexor rms EMG integrated over the torque reaction phase was 839 Ns for long torque reaction times and decreased to 312 Ns for short torque reaction times. The average latency between tool spindle torque onset and peak initial flexor rms EMG for long torque reaction times was 294 ms which decreased to 161 ms for short torque reaction times. The average latency between peak tool spindle torque, just prior to tool shut-off, and peak final rms EMG for long torque reaction times was 97 ms for flexors and 188 ms for extensors, which decreased for short torque reaction times to 47

  11. Effort, performance, and motivation: insights from robot-assisted training of human golf putting and rat grip strength.

    Science.gov (United States)

    Duarte, Jaime E; Gebrekristos, Berkenesh; Perez, Sergi; Rowe, Justin B; Sharp, Kelli; Reinkensmeyer, David J

    2013-06-01

    Robotic devices can modulate success rates and required effort levels during motor training, but it is unclear how this affects performance gains and motivation. Here we present results from training unimpaired humans in a virtual golf-putting task, and training spinal cord injured (SCI) rats in a grip strength task using robotically modulated success rates and effort levels. Robotic assistance in golf practice increased trainees feelings of competence, and, paradoxically, increased their sense effort, even though it had mixed effects on learning. Reducing effort during a grip strength training task led rats with SCI to practice the task more frequently. However, the more frequent practice of these rats did not cause them to exceed the strength gains achieved by rats that exercised less often at higher required effort levels. These results show that increasing success and decreasing effort with robots increases motivation, but has mixed effects on performance gains.

  12. Feasibility of an Assessment Tool for Children's Competence to Consent to Predictive Genetic Testing: a Pilot Study.

    Science.gov (United States)

    Hein, Irma M; Troost, Pieter W; Lindeboom, Robert; Christiaans, Imke; Grisso, Thomas; van Goudoever, Johannes B; Lindauer, Ramón J L

    2015-12-01

    Knowledge on children's capacities to consent to medical treatment is limited. Also, age limits for asking children's consent vary considerably between countries. Decision-making on predictive genetic testing (PGT) is especially complicated, considering the ongoing ethical debate. In order to examine just age limits for alleged competence to consent in children, we evaluated feasibility of a standardized assessment tool, and investigated cutoff ages for children's competence to consent to PGT. We performed a pilot study, including 17 pediatric outpatients between 6 and 18 years at risk for an autosomal dominantly inherited cardiac disease, eligible for predictive genetic testing. The reference standard for competence was established by experts trained in the relevant criteria for competent decision-making. The MacArthur Competence Assessment Tool for Treatment (MacCAT-T) served as index test. Data analysis included raw agreement between competence classifications, difference in mean ages between children judged competent and judged incompetent, and estimation of cutoff ages for judgments of competence. Twelve (71 %) children were considered competent by the reference standard, and 16 (94 %) by the MacCAT-T, with an overall agreement of 76 %. The expert judgments disagreed in most cases, while the MacCAT-T judgments agreed in 65 %. Mean age of children judged incompetent was 9.3 years and of children judged competent 12.1 years (p = .035). With 90 % sensitivity, children younger than 10.0 years were judged incompetent, with 90 % specificity children older than 11.8 years were judged competent. Feasibility of the MacCAT-T in children is confirmed. Initial findings on age cutoffs are indicative for children between the age of 12 and 18 to be judged competent for involvement in the informed consent process. Future research on appropriate age-limits for children's alleged competence to consent is needed.

  13. Public perceptions of a rip current hazard education program: "Break the Grip of the Rip!"

    Science.gov (United States)

    Houser, Chris; Trimble, Sarah; Brander, Robert; Brewster, B. Chris; Dusek, Greg; Jones, Deborah; Kuhn, John

    2017-07-01

    Rip currents pose a major global beach hazard; estimates of annual rip-current-related deaths in the United States alone range from 35 to 100 per year. Despite increased social research into beach-goer experience, little is known about levels of rip current knowledge within the general population. This study describes the results of an online survey to determine the extent of rip current knowledge across the United States, with the aim of improving and enhancing existing beach safety education material. Results suggest that the US-based Break the Grip of the Rip!® campaign has been successful in educating the public about rip current safety directly or indirectly, with the majority of respondents able to provide an accurate description of how to escape a rip current. However, the success of the campaign is limited by discrepancies between personal observations at the beach and rip forecasts that are broadcasted for a large area and time. It was the infrequent beach user that identified the largest discrepancies between the forecast and their observations. Since infrequent beach users also do not seek out lifeguards or take the same precautions as frequent beach users, it is argued that they are also at greatest risk of being caught in a dangerous situation. Results of this study suggest a need for the national campaign to provide greater focus on locally specific and verified rip forecasts and signage in coordination with lifeguards, but not at the expense of the successful national awareness program.

  14. In the grip of the python: conflicts at the university-industry interface.

    Science.gov (United States)

    Healy, David

    2003-01-01

    When the University of Toronto withdrew a contract it held with me in December 2000, it initiated a sequence of events that led to a public letter to the University from senior figures in the world psychopharmacology community protesting against the infringement of academic freedom involved and a first ever legal action, undertake by this author, seeking redress for a violation of academic freedom. The issues of academic freedom surrounding this case have been intertwined with a debate about the possibility that the selective serotonin reuptake inhibitor (SSRI) group of antidepressants have the potential to trigger suicidality in a subgroup of patients. Whether the SSRIs do trigger suicidality or not, exploration of this issue has given rise to a number of worrying sets of observations. First, in my view, there is evidence that pharmaceutical companies have miscoded raw data on suicidal acts and suicidal ideation. Second, this author also maintains that there is a growing body of examples of ghostwriting of articles in the therapeutics domain. Many of the tensions evident in this case, therefore, can be linked to company abilities to keep clinical trial data out of the public domain--this is the point at which the pharmaceutical python gets a grip on academia.

  15. Simulation study of a single-grip harvester in thinning from below and thinning from above

    Energy Technology Data Exchange (ETDEWEB)

    Eliasson, Lars [Swedish Univ. of Agricultural Sciences, Umeaa (Sweden). Dept. of Silviculture; Lageson, Haakan [Forest Owner' s Ass. of Norrbotten, Boden (Sweden)

    1999-07-01

    The time consumption and productivity of a single-grip harvester were studied, using a simulation model, when thinning from below and above in eight randomly selected stands. The model estimated the time required for each work element, given machine and tree positions, and tree size. A 2 x 5 factorial design was used with factors thinning type [from below (T{sub b}) and above (T{sub a})] and tree size. Trees were subjectively selected for harvest according to thinning type. Total basal area removal was 30% plot{sup -1}. Approximately 50% more trees were harvested in T{sub b} than in T{sub a}. Time consumption tree{sup -1} was higher for T{sub a} than T{sub b}. Time consumption for machine and boom movements decreased with increasing number of harvested trees, and time for felling and processing of trees increased with harvested mean stem volume. Harvester productivity was 36% higher for T{sub a}, since the increase in harvested mean stem volume was higher than the increase in time consumption tree{sup -1}.

  16. The predictive value of extensor grip test for the effectiveness of treatment for tennis elbow

    International Nuclear Information System (INIS)

    Zehtab, Mohammad J.; Mirghasemi, A.; Majlesara, A.; Siavashi, B.; Tajik, P.

    2008-01-01

    Objective was to compare the effectiveness of 5 different modalities and determine the usefulness of recently proposed extensor grip test (EGT) in predicting the response to treatment. In a randomized controlled clinical trial, 92 of 98 tennis elbow patients in Sina Hospital Tehran, Iran between 2006 and 2007 fulfilled the trial entry criteria. Among these patients 56 (60.9%) had positive EGT results, were randomly allocated to 5 treatment groups: brace, physiotherapy, brace plus physiotherapy, injection and injection plus physiotherapy. Patients with a positive EGT result had better response to treatments. Among them, injection plus physiotherapy was the most successful, then brace plus physiotherapy was the worst treatment modality. Response to treatment was comparable in all groups between EGT positive and negative patients except bracing, in which positive EGT was correlated with dramatic response to treatment. In all patients, injection plus physiotherapy and the brace plus physiotherapy is recommended, but in EGT negatives, bracing seems to be of no use. Injection alone is not recommended in either group. (author)

  17. Simple and Reliable Method to Estimate the Fingertip Static Coefficient of Friction in Precision Grip.

    Science.gov (United States)

    Barrea, Allan; Bulens, David Cordova; Lefevre, Philippe; Thonnard, Jean-Louis

    2016-01-01

    The static coefficient of friction (µ static ) plays an important role in dexterous object manipulation. Minimal normal force (i.e., grip force) needed to avoid dropping an object is determined by the tangential force at the fingertip-object contact and the frictional properties of the skin-object contact. Although frequently assumed to be constant for all levels of normal force (NF, the force normal to the contact), µ static actually varies nonlinearly with NF and increases at low NF levels. No method is currently available to measure the relationship between µ static and NF easily. Therefore, we propose a new method allowing the simple and reliable measurement of the fingertip µ static at different NF levels, as well as an algorithm for determining µ static from measured forces and torques. Our method is based on active, back-and-forth movements of a subject's finger on the surface of a fixed six-axis force and torque sensor. µ static is computed as the ratio of the tangential to the normal force at slip onset. A negative power law captures the relationship between µ static and NF. Our method allows the continuous estimation of µ static as a function of NF during dexterous manipulation, based on the relationship between µ static and NF measured before manipulation.

  18. Getting a Grip on the Handgrip Task: Handgrip Duration Correlates with Neuroticism But Not Conscientiousness

    Directory of Open Access Journals (Sweden)

    Simon B. Goldberg

    2017-08-01

    Full Text Available Questions regarding the replicability of key findings in the self-regulation literature (e.g., ego-depletion effect have led some to call for a more thorough evaluation of commonly used measures of self-control. The isometric handgrip task is one such measure. The current study examined correlates of handgrip persistence using data drawn from a larger randomized controlled trial. Handgrip persistence was measured both at baseline and following a physical stressor (cold pressor test. Correlations were examined between handgrip performance and personality traits theoretically closely linked with self-regulation: conscientiousness and neuroticism. Baseline handgrip performance was correlated with several measures drawn from the nomological network of self-regulation including measures of trait neuroticism, mindfulness, anxiety sensitivity, perceived stress, and positive affect, although not with trait conscientiousness. Baseline handgrip predicted aversiveness experienced during the physical stressor, while changes in handgrip performance tracked changes in implicit and explicit negative affect (i.e., affective reactivity. These associations were largely maintained when controlling for variables highly correlated with overall grip strength (i.e., gender, height, and weight, although correlations separated by gender suggest associations were primarily driven by female participants. Results support future research using the handgrip task.

  19. Key Insights into Hand Biomechanics: Human Grip Stiffness Can Be Decoupled from Force by Cocontraction and Predicted from Electromyography

    Directory of Open Access Journals (Sweden)

    Hannes Höppner

    2017-05-01

    Full Text Available We investigate the relation between grip force and grip stiffness for the human hand with and without voluntary cocontraction. Apart from gaining biomechanical insight, this issue is particularly relevant for variable-stiffness robotic systems, which can independently control the two parameters, but for which no clear methods exist to design or efficiently exploit them. Subjects were asked in one task to produce different levels of force, and stiffness was measured. As expected, this task reveals a linear coupling between force and stiffness. In a second task, subjects were then asked to additionally decouple stiffness from force at these force levels by using cocontraction. We measured the electromyogram from relevant groups of muscles and analyzed the possibility to predict stiffness and force. Optical tracking was used for avoiding wrist movements. We found that subjects were able to decouple grip stiffness from force when using cocontraction on average by about 20% of the maximum measured stiffness over all force levels, while this ability increased with the applied force. This result contradicts the force–stiffness behavior of most variable-stiffness actuators. Moreover, we found the thumb to be on average twice as stiff as the index finger and discovered that intrinsic hand muscles predominate our prediction of stiffness, but not of force. EMG activity and grip force allowed to explain 72 ± 12% of the measured variance in stiffness by simple linear regression, while only 33 ± 18% variance in force. Conclusively the high signal-to-noise ratio and the high correlation to stiffness of these muscles allow for a robust and reliable regression of stiffness, which can be used to continuously teleoperate compliance of modern robotic hands.

  20. The Relationship of Digit Ratio (2D:4D) with Cerebral Lateralization and Grip Strength in Elite Swimmers

    Science.gov (United States)

    Acar, Hakan; Eler, Nebahat

    2018-01-01

    The index finger and the 4th finger ratio (2D:4D) is the indicator of the prenatal testosterone. The aim of this study is to investigate the relationship between 2D:4D, hand preference and hand grip strength in swimmers. A total of 80 elite swimmers, participated in the study. Height, body weight, body mass index (BMI), hand 2D:4D finger…

  1. Constraints on grip selection in hemiparetic cerebral palsy: effects of lesional side, end-point accuracy, and context.

    Science.gov (United States)

    Steenbergen, Bert; Meulenbroek, Ruud G J; Rosenbaum, David A

    2004-04-01

    This study was concerned with selection criteria used for grip planning in adolescents with left or right hemiparetic cerebral palsy. In the first experiment, we asked participants to pick up a pencil and place the tip in a pre-defined target region. We varied the size of the target to test the hypothesis that increased end-point precision demands would favour the use of a grip that affords end-state comfort. In the second experiment, we studied grip planning in three task contexts that were chosen to let us test the hypothesis that a more functional task context would likewise promote the end-state comfort effect. When movements were performed with the impaired hand, we found that participants with right hemiparesis (i.e., left brain damage) aimed for postural comfort at the start rather than at the end of the object-manipulation phase in both experiments. By contrast, participants with left hemiparesis (i.e., right brain damage) did not favour a particular selection criterion with the impaired hand in the first experiment, but aimed for postural comfort at the start in the second experiment. When movements were performed with the unimpaired hand, grip selection criteria again differed for right and left hemiparetic participants. Participants with right hemiparesis did not favour a particular selection criterion with the unimpaired hand in the first experiment and only showed the end-state comfort effect in the most functional tasks of the second experiment. By contrast, participants with left hemiparesis showed the end-state comfort effect in all conditions of both experiments. These data suggest that the left hemisphere plays a special role in action planning, as has been recognized before, and that one of the deficits accompanying left brain damage is a deficit in forward movement planning, which has not been recognized before. Our findings have both theoretical and clinical implications.

  2. Test-Retest Reliability of Measurements of Hand-Grip Strength Obtained by Dynamometry from Older Adults: A Systematic Review of Research in the PubMed Database.

    Science.gov (United States)

    Bohannon, R W

    2017-01-01

    A systematic review was performed to summarize literature describing the test-retest reliability of grip strength measures obtained from older adults. Relevant literature was identified via a PubMed search. Seventeen articles were deemed appropriate based on inclusion and exclusion criteria. The relative test-retest reliability of grip strength measures obtained by dynamometry was good to excellent (intra-class correlation coefficients > 0.80) in all but 3 studies, which involved older adults with severe dementia. Absolute reliability, as indicated by summary statistics such as the minimum detectable change (95%), was more variable. As a percentage, that change ranged from 14.5% to 98.5%. Consequently, clinicians can be confident in the relative reliability of grip strength measures obtained from at risk older adults. However, relatively large percentage changes in grip strength may be necessary to conclude with confidence that a real change has occurred over time in some populations.

  3. Installation of dynamic travel time signs and efforts to obtain and test a graphical route information panel (GRIP) sign in Austin.

    Science.gov (United States)

    2016-08-01

    Graphic Route Information Panel (GRIP) signs use a combination of text, colors, and representative maps of : the roadway system to convey real-time roadway congestion location and severity information. The intent of : this project was to facilitate t...

  4. Wheelchair Mobility Performance enhancement by Changing Wheelchair Properties; What is the Effect of Grip, Seat Height and Mass?

    Science.gov (United States)

    van der Slikke, Rienk M A; de Witte, Annemarie M H; Berger, Monique A M; Bregman, Daan J J; Veeger, Dirk Jan H E J

    2018-02-12

    The purpose of this study was to provide insight in the effect of wheelchair settings on wheelchair mobility performance. Twenty elite wheelchair basketball athletes of low (n=10) and high classification (n=10), were tested in a wheelchair basketball directed field test. Athletes performed the test in their own wheelchair, which was modified for five additional conditions regarding seat height (high - low), mass (central - distributed) and grip. The previously developed, inertial sensor based wheelchair mobility performance monitor 1 was used to extract wheelchair kinematics in all conditions. Adding mass showed most effect on wheelchair mobility performance, with a reduced average acceleration across all activities. Once distributed, additional mass also reduced maximal rotational speed and rotational acceleration. Elevating seat height had effect on several performance aspects in sprinting and turning, whereas lowering seat height influenced performance minimally. Increased rim grip did not alter performance. No differences in response were evident between low and high classified athletes. The wheelchair mobility performance monitor showed sensitive to detect performance differences due to the small changes in wheelchair configuration made. Distributed additional mass had the most effect on wheelchair mobility performance, whereas additional grip had the least effect of conditions tested. Performance effects appear similar for both low and high classified athletes. Athletes, coaches and wheelchair experts are provided with insight in the performance effect of key wheelchair settings, and they are offered a proven sensitive method to apply in sports practice, in their search for the best wheelchair-athlete combination.

  5. Development of force sensing circuit to determine the optimal force required for effective dynamic tripod grip/writing

    Science.gov (United States)

    Suraj S., S.; Kulkarni, Palash; Bokadia, Pratik; Ramanathan, Prabhu; Nageswaran, Sharmila

    2018-04-01

    Handwriting is a combination of fine motor perceptions and cognitive skills to produce words on paper. For writing, the most commonly used and recommended grip is the dynamic tripod grip. A child's handwriting starts developing during the times of pre-schooling and improves over time. While writing, children apply excessive force on the writing instrument. This force is exerted by their fingers and as per the law of reaction, the writing instruments tend to exert an equal and opposite force, that could damage the delicate soft tissue structures in their fingers and initiate cramps and pains. This condition is also prevalent in adults who tend to write for long hours under pressure. An example would be adolescence student during the exams. Clinically this condition is termed as `Writer's Cramp', which is usually characterized by muscle fatigue and pain in the fingers. By understanding and fixing the threshold of the force that should be exerted by the fingers while gripping the instrument, the pain can be controlled or avoided. This research aims in designing an electronic module which can help in understanding the threshold of pressure which is optimum enough to establish a better contact between the fingers and the instrument and should be capable of controlling or avoiding the pain. The design of FSR based electronic system is explained with its circuitry and results of initial testing is presented in this paper.

  6. Anticipating different grips reduces bimanual end-state comfort: A tradeoff between goal-related and means-related planning processes.

    Directory of Open Access Journals (Sweden)

    Christian Seegelke

    Full Text Available The present study explored the sensitivity towards bimanual end-state comfort in a task that required anticipating different final grips. Participants simultaneously reached and grasped two objects with either a whole-hand grip (WHG or a precision grip (PG, and placed them at two target locations by transporting them either over or under an obstacle. The transport path was varied such that it could be either congruent (i.e., both objects over or under or incongruent (i.e., one object over and the other object under. In the congruent conditions, participants satisfied bimanual end-state comfort (and identical initial grips on the majority of trials. That is, participants adopted a PG for either hand when the objects were transported over the obstacle and a WHG for either hand when the objects were transported under the obstacle. In contrast, in the incongruent conditions, bimanual end-state comfort was significantly reduced, indicating the presence of intermanual inference. The results indicate that goal-related planning constraints (i.e., bimanual end-state comfort do not strictly take precedence over means-related constraints (i.e., identical initial grips if this requires anticipating different final grips. Thus, bimanual end-state comfort per se does not provide a predominant constraint in action selection, by which sensorimotor interference can be reduced. In line with the proposal that bimanual grip planning relies on a flexible constraint hierarchy, a simple formal model that considers bimanual grip posture planning as a tradeoff between goal-related and means-related planning processes can explain our results reasonably well.

  7. The Vacuum-Compacted Regolith Gripping Mechanism and Unmanned Flights via Quad-Rotors

    Science.gov (United States)

    Scott, Rollin L.

    2014-01-01

    During the course of the Kennedy Space Center Summer Internship, two main experiments were performed: The Vacuum-Compacted Regolith Gripping Mechanism and Unmanned Flights via Quad-copters. The objectives of the Vacuum-Compacted Regolith Gripping Mechanism, often abbreviated as the Granular Gripper, are to exhibit Space Technology, such as a soft robotic hand, lift different apparatuses used to excavate regolith, and conserve energy while executing its intended task. The project is being conducted to test how much weight the Granular Gripper can hold. With the use of an Animatronic Robotic Hand, Arduino Uno, and other components, the system was calibrated before actually conducting the intended weight test. The maximum weight each finger could hold with the servos running, in the order of pinky, ring, middle, and index fingers, are as follows: 1.340N, 1.456 N, 0.9579 N, and 1.358 N. Using the small vacuum pump system, the maximum weight each finger could hold, in the same order, was: 4.076 N, 6.159 N, 5.454 N, and 4.052 N. The maximum torques on each of the fingers when the servos were running, in the same respective order, was: 0.0777 Nm, 0.0533 Nm, 0.0648 Nm, and 0.0532 Nm. The maximum torques on the individual fingers, when the small vacuum pump was in effect, in the same order as above, was: 0.2318 Nm, 0.3032 Nm, 0.2741 Nm, and 0.1618 Nm. In testing all the fingers with the servos running, the total weight was 5.112 N and the maximum torque on the all the fingers was 0.2515 Nm. However, when the small vacuum pump system was used, the total weight was 19.741 N and the maximum torque on the all the fingers was 0.9713 Nm. The conclusion that was drawn stated that using the small vacuum pump system proved nearly 4 times more effective when testing how much weigh the hand could hold. The resistance provided by the compacted sand in the glove allowed more weight to be held by the hand and glove. Also, when the servos turned off and the hand still retaining its

  8. Self-organization, free energy minimization, and optimal grip on a field of affordances

    Directory of Open Access Journals (Sweden)

    Jelle eBruineberg

    2014-08-01

    Full Text Available In this paper, we set out to develop a theoretical and conceptual framework for the new field of Radical Embodied Cognitive Neuroscience. This framework should be able to integrate insights from several relevant disciplines: theory on embodied cognition, ecological psychology, phenomenology, dynamical systems theory, and neurodynamics. We suggest that the main task of Radical Embodied Cognitive Neuroscience is to investigate the phenomenon of skilled intentionality from the perspective of the self-organization of the brain-body-environment system, while doing justice to the phenomenology of skilled action. In previous work, we have characterized skilled intentionality as the organism’s tendency towards an optimal grip on multiple relevant affordances simultaneously. Affordances are possibilities for action provided by the environment. In the first part of this paper, we introduce the notion of skilled intentionality and the phenomenon of responsiveness to a field of relevant affordances. Second, we use Friston’s work on neurodynamics, but embed a very minimal version of his Free Energy Principle in the ecological niche of the animal. Thus amended, this principle is helpful for understanding the embeddedness of neurodynamics within the dynamics of the brain-body-environment system. Next, we show how we can use this adjusted principle to understand the neurodynamics of selective openness to the environment: interacting action-readiness patterns at multiple timescales contribute to the organism’s selective openness to relevant affordances. In the final part of the paper, we emphasize the important role of metastable dynamics in both the brain and the brain-body-environment system for adequate affordance-responsiveness. We exemplify our integrative approach by presenting research on the impact of Deep Brain Stimulation on affordance responsiveness of OCD patients.

  9. Self-organization, free energy minimization, and optimal grip on a field of affordances.

    Science.gov (United States)

    Bruineberg, Jelle; Rietveld, Erik

    2014-01-01

    In this paper, we set out to develop a theoretical and conceptual framework for the new field of Radical Embodied Cognitive Neuroscience. This framework should be able to integrate insights from several relevant disciplines: theory on embodied cognition, ecological psychology, phenomenology, dynamical systems theory, and neurodynamics. We suggest that the main task of Radical Embodied Cognitive Neuroscience is to investigate the phenomenon of skilled intentionality from the perspective of the self-organization of the brain-body-environment system, while doing justice to the phenomenology of skilled action. In previous work, we have characterized skilled intentionality as the organism's tendency toward an optimal grip on multiple relevant affordances simultaneously. Affordances are possibilities for action provided by the environment. In the first part of this paper, we introduce the notion of skilled intentionality and the phenomenon of responsiveness to a field of relevant affordances. Second, we use Friston's work on neurodynamics, but embed a very minimal version of his Free Energy Principle in the ecological niche of the animal. Thus amended, this principle is helpful for understanding the embeddedness of neurodynamics within the dynamics of the system "brain-body-landscape of affordances." Next, we show how we can use this adjusted principle to understand the neurodynamics of selective openness to the environment: interacting action-readiness patterns at multiple timescales contribute to the organism's selective openness to relevant affordances. In the final part of the paper, we emphasize the important role of metastable dynamics in both the brain and the brain-body-environment system for adequate affordance-responsiveness. We exemplify our integrative approach by presenting research on the impact of Deep Brain Stimulation on affordance responsiveness of OCD patients.

  10. Hand Grip Strength in Low, Medium, and High Body Mass Index Males and Females

    Directory of Open Access Journals (Sweden)

    Liao

    2016-01-01

    Full Text Available Background Hand grip strength (HGS is a predictor of upper extremity function and changes in muscle strength, physical movement and ability to undertake activities of daily living. Body mass index (BMI is a critical indicator of physical health; however, the relationship between HGS and BMI has not yet been thoroughly examined. Objectives The current study aims to compare HGS in low, medium, and high BMI males and females in both hands, and also investigates the correlation between HGS and anthropometric characteristics among the three BMI groups. Patients and Methods The study included 200 participants who were divided into three groups based on their BMI (60 low, 58 medium, and 82 high. HGS was assessed using a hand-held Jamar dynamometer. BMI was assessed by an electric body-weight height analysis machine. Data was analyzed using descriptive and inferential statistics at P 0.05. Weight and height strongly correlated with HGS for hands (correlation (r ranged from 0.000 - 0.775. Regression analysis showed that when using sex and BMI as independent variables for predicting the dependent variable HGS, the coefficient of the determinant R2 was 0.753 (P < 0.001. Conclusions The current study revealed that a significant difference existed in HGS among the low, medium, and high BMI groups. A positive correlation existed between HGS and weight and height, while sex was the most significant factor affecting HGS. These findings can serve as a reference to assess HGS prediction, whereby the sex effect should be considered.

  11. An investigation of the tri-bar gripping system on isometric muscular endurance.

    Science.gov (United States)

    Drury, Daniel G; Faggiono, Heath; Stuempfle, Kristin J

    2004-11-01

    Recently, a new product called the Tri-Bar has been introduced as an alternative to the standard round weightlifting bar. The Tri-Bar has the same weight, length, and circumference as a standard weightlifting bar and differs only in that the shape of the bar is formed like a triangle with rounded edges. Theoretically, the shape of the bar will enhance gripping comfort and increase muscular endurance. We studied 32 moderately trained males who were free from upper-body injury or limitation. Each participant completed 4 visits to the lab as part of 2 separate investigations. The first investigation was a comparison of straight-arm hang times while grasping a standard Olympic bar or a Tri-Bar attached to the top of a power rack. The second investigation involved grasping a standard revolving cable handle or a Tri-Bar revolving handle attached to a weight equal to half the subject's body weight. In both investigations, time was used as a measure of isometric muscular endurance. Differences were determined using a dependent t-test, and a level of significance was set at p < 0.05. Mean hang times were significantly longer when the men hung from the Tri-Bar (107.6 seconds) versus the standard bar (95.4 seconds) (p = 0.015). Conversely, in the investigation using the revolving handles, the round bar produced longer grasping times (71.5 seconds) than the Tri-Bar (62.6 seconds) (p = 0.000). The results of this investigation indicate that a fixed and stable Tri-Bar may help to increase hang time, but a Tri-Bar free to rotate within the grasp may decrease grasping time in comparison to a standard round handle. With regard to exercises that require isometric grasping, the Tri-Bar may be an effective alternative to the standard bar for increasing isometric grasping endurance.

  12. Effects of gripping volume in the mechanical strengths of orthodontic mini-implant

    Directory of Open Access Journals (Sweden)

    Yu-Chuan Tseng

    2017-11-01

    Full Text Available The objective of study was to investigate the correlation between the mechanical strengths [insertion torque (IT; resonance frequency (RF; and horizontal pullout strength (HPS] and gripping volume (GV of mini-implants. Thirty mini-implants of three types (Type A: 2 mm × 10 mm, cylindrical, titanium alloy; Type B: 2 mm × 10 mm, tapered, stainless steel; and Type C: 2 mm × 11 mm, cylindrical, titanium alloy were inserted 7 mm into artificial bones. One-way analysis of variance and Spearman's test were applied to assess intergroup comparisons and intragroup correlations. The null hypothesis was that no statistically significant correlations exist between the GV and mechanical strengths (IT, RF, and HPS. In the IT test, Type C (14.2 Ncm had significantly (p=0.016 greater values than did Type A (12.4 Ncm. In the RF analysis, no significant difference was observed among the three types of mini-implants. In the HPS test, Type C (388.9 Ncm was significantly larger than both Type B (294.5 Ncm and Type A (286 Ncm. In the GV measurement, Type C (14.4 mm3 was significantly larger than Type B (11.4 mm3 and Type A (9.2 mm3. Type A and Type B exhibited no significant correlations among the tests. Therefore, the null hypothesis was accepted. Although no significant correlation was noted between the GV and mechanical strengths (IT, RF, and HPS, we observed a trend that the mechanical strengths (IT, RF, and HPS of the mini-implants corresponded to the order and values of GV (Type C > Type B > Type A.

  13. Superposition of automatic and voluntary aspects of grip force control in humans during object manipulation.

    Directory of Open Access Journals (Sweden)

    Frederic Danion

    Full Text Available When moving grasped objects, people automatically modulate grip force (GF with movement-dependent load force (LF in order to prevent object slip. However, GF can also be modulated voluntarily as when squeezing an object. Here we investigated possible interactions between automatic and voluntary GF control. Participants were asked to generate horizontal cyclic movements (between 0.6 and 2.0 Hz of a hand-held object that was restrained by an elastic band such that the load force (LF reached a peak once per movement cycle, and to simultaneously squeeze the object at each movement reversal (i.e., twice per cycle. Participants also performed two control tasks in which they either only moved (between 0.6 and 2.0 Hz or squeezed (between 1.2 and 4.0 Hz the object. The extent to which GF modulation in the simultaneous task could be predicted from the two control tasks was assessed using power spectral analyses. At all frequencies, the GF power spectra from the simultaneous task exhibited two prominent components that occurred at the cycle frequency (ƒ and at twice this frequency (2ƒ, whereas the spectra from the movement and squeeze control task exhibited only single peaks at ƒ and 2ƒ, respectively. At lower frequencies, the magnitudes of both frequency components in the simultaneous task were similar to the magnitudes of the corresponding components in the control tasks. However, as frequency increased, the magnitudes of both components in the simultaneous task were greater than the magnitudes of the corresponding control task components. Moreover, the phase relationship between the ƒ components of GF and LF began to drift from the value observed in the movement control task. Overall these results suggest that, at lower movement frequencies, voluntary and automatic GF control processes operate at different hierarchical levels. Several mechanisms are discussed to account for interaction effects observed at higher movement frequencies.

  14. Association of the AMPA receptor-related postsynaptic density proteins GRIP and ABP with subsets of glutamate-sensitive neurons in the rat retina.

    Science.gov (United States)

    Gábriel, Robert; de Souza, Sunita; Ziff, Edward B; Witkovsky, Paul

    2002-07-22

    We used specific antibodies against two postsynaptic density proteins, GRIP (glutamate receptor interacting protein) and ABP (AMPA receptor-binding protein), to study their distribution in the rat retina. In the central nervous system, it has been shown that both proteins bind strongly to the AMPA glutamate receptor (GluR) 2/3 subunits, but not other GluRs, through a set of three PDZ domains. Western blots detected a single GRIP protein that was virtually identical in retina and brain, whereas retinal ABP corresponded to only one of three ABP peptides found in brain. The retinal distributions of GluR2/3, GRIP, and ABP immunoreactivity (IR) were similar but not identical. GluR2/3 immunoreactivity (IR) was abundant in both plexiform layers and in large perikarya. ABP IR was concentrated in large perikarya but was sparse in the plexiform layers, whereas GRIP IR was relatively more abundant in the plexiform layers than in perikarya. Immunolabel for these three antibodies consisted of puncta ABP IR was examined by double labeling subclasses of retinal neuron with characteristic marker proteins, e.g., calbindin. GRIP, ABP, and GluR2/3 IR were detected in horizontal cells, dopaminergic and glycinergic AII amacrine cells and large ganglion cells. Immunolabel was absent in rod bipolar and weak or absent in cholinergic amacrine cells. By using the tyramide method of signal amplification, a colocalization of GluR2/3 was found with either GRIP or ABP in horizontal cell terminals, and perikarya of amacrine and ganglion cells. Our results show that ABP and GRIP colocalize with GluR2/3 in particular subsets of retinal neuron, as was previously established for certain neurons in the brain. Copyright 2002 Wiley-Liss, Inc.

  15. Grip strength in a cohort of older medical inpatients in Malaysia: a pilot study to describe the range, determinants and association with length of hospital stay.

    Science.gov (United States)

    Keevil, Victoria; Mazzuin Razali, Rizah; Chin, Ai-Vyrn; Jameson, Karen; Aihie Sayer, Avan; Roberts, Helen

    2013-01-01

    Grip strength is a marker of sarcopenia, the age-related decline in muscle mass and function, and has been little researched in Asian populations. We aimed to describe the feasibility and acceptability of measuring grip strength in hospitalized, older people in Malaysia and to explore its range, determinants and association with length of stay. Patients admitted acutely to the geriatrics ward of a teaching hospital were consecutively recruited. Inability to consent or use the dynamometer led to exclusion. Maximum grip strength, anthropometric data, length of hospital stay, discharge destination, 3-point Barthel score, mini-mental state examination, falls history and number of co-morbidities and medications on admission were recorded. 80/153 (52%) eligible patients were recruited (52 women; age range 64-100 years). 9/153 (6%) refused to participate and 64/153 (42%) were excluded (34 too unwell, 24 unable to consent, 4 unable to use the dynamometer, 2 other reasons). 76/80 patients (95%) reported that they would undergo grip strength measurement again. Determinants were similar to those of Caucasian populations but grip strength values were lower. After adjustment for sex, age and height, stronger grip strength was associated with shorter length of stay [hazard ratio 1.05 (95% CI 1.00, 1.09; P=0.03)]. This is the first report of grip strength measurement in hospitalized older people in Malaysia. It was feasible, acceptable to participants and associated with length of stay. Further research is warranted to elucidate the normative range in different ethnic groups and explore its potential use in clinical practice in Malaysia. Copyright © 2012 Elsevier Ireland Ltd. All rights reserved.

  16. alpha2 adrenoceptors are involved in the regulation of the gripping-induced immobility episodes in taiep rats.

    Science.gov (United States)

    Eguibar, José R; Cortés, Ma Del Carmen; Valencia, Jaime; Arias-Montaño, José A

    2006-10-01

    In 1989 Holmgren et al. (Holmgren et al. 1989 Lab Anim Sci 39:226-228) described a new mutant rat that developed a progressive motor disturbance during its lifespan. The syndrome is characterized by a tremor in the hind limbs followed by ataxia, episodes of tonic immobility, epilepsy, and paralysis. The acronym of these symptoms (taiep) became the name of this autosomic, recessive mutant rat. The taiep rats are neurological mutant animals with a hypomyelination, followed by a progressive demyelination process. At 7-8 months of age, taiep rats develop immobility episodes (IEs) characterized by a cortical desynchronization, associated with the theta rhythm in the hippocampus and changes of the nucal electromyogram (EMG), whose pattern is like rapid-eye-movement (REM) sleep. These rats also show an altered sleep pattern with an equal REM sleep distribution. This study analyzed therole of alpha(2) adrenoceptors in the expression of gripping-induced IEs in 8-month-old male taiep rats. The alpha(2) adrenoceptor agonists clonidine and xylacine increased the frequency of gripping-induced IEs whereas the alpha(2) antagonists yohimbine and idazoxandecreased or prevented such episodes. These findings correlate with the pharmacological observations in narcoleptic dogs and humans in which alpha(2) adrenergic mechanisms are involved in the modulation of cataplexy. Unexpectedly, the repetitive administration of clonidine resulted in jumping behavior, indicative of phasic activation of extensor musculature. Taken together, our results show that alpha(2) adrenoceptors are involved in the modulation in gripping-induced IEs and after the administration of several doses of clonidine produced phasic motor activation.

  17. Vitamin D status predicts hand-grip strength in young adult women living in Auckland, New Zealand.

    Science.gov (United States)

    von Hurst, P R; Conlon, C; Foskett, A

    2013-07-01

    The identification of the vitamin D receptor (VDR) in skeletal muscle tissue and research in muscle strength and development in VDR-null mice confirms a role for vitamin D in muscle function. The relationship between muscle strength and vitamin D status has been explored to some degree in older populations with regard to fall prevention, but there has been very little research in younger adults. This cross-sectional study considered the predictors of muscle strength in 137 young women (19-29 years) living in New Zealand. The following measurements were taken in the latter months of winter: plasma 25OHD, dominant (HGD) and non-dominant hand-grip (HGND) strength (hand-grip dynamometer), counter measure jump, and recreational physical activity (RPA) assessed from a recent physical activity questionnaire (RPAQ). Dietary intake was measured with a four-day food diary, and body composition using air displacement plethysmography. This was a relatively inactive group of women; total RPA ranged from 0 to 3.93h per week, mean (SD) 0.86(0.74) h, approximately 50% comprised outdoor activities. Mean 25OHD was 54(28)nmol/l, HGD and HGND were significantly different (t=6.049, pstrength as the dependent variable (Model R(2)=0.11, p=0.001 non-dominant, R(2)=0.13, pstrength and serum 25OHD, and when each were adjusted to remove this association, 25OHD accounted for 4.3% of HGND and 4.5% of HGD. These results suggest that vitamin D status does have a small but significant association with hand-grip strength in this group of young women. Further investigation in this age group with a randomised controlled trial is justified. This article is part of a Special Issue entitled 'Vitamin D Workshop'. Copyright © 2012 Elsevier Ltd. All rights reserved.

  18. Real time relationship between individual finger force and grip exertion on distal phalanges in linear force following tasks.

    Science.gov (United States)

    Luo, Shi-Jian; Shu, Ge; Gong, Yan

    2018-05-01

    Individual finger force (FF) in a grip task is a vital concern in rehabilitation engineering and precise control of manipulators because disorders in any of the fingers will affect the stability or accuracy of the grip force (GF). To understand the functions of each finger in a dynamic grip exertion task, a GF following experiment with four individual fingers without thumb was designed. This study obtained four individual FFs from the distal phalanges with a cylindrical handle in dynamic GF following tasks. Ten healthy male subjects with similar hand sizes participated in the four-finger linear GF following tasks at different submaximal voluntary contraction (SMVC) levels. The total GF, individual FF, finger force contribution, and following error were subsequently calculated and analyzed. The statistics indicated the following: 1) the accuracy and stability of GF at low %MVC were significantly higher than those at high SMVC; 2) at low SMVC, the ability of the fingers to increase the GF was better than the ability to reduce it, but it was contrary at high SMVC; 3) when the target wave (TW) was changing, all four fingers strongly participated in the force exertion, but the participation of the little finger decreased significantly when TW remained stable; 4) the index finger and ring finger had a complementary relationship and played a vital role in the adjustment and control of GF. The middle finger and little finger had a minor influence on the force control and adjustment. In conclusion, each of the fingers had different functions in a GF following task. These findings can be used in the assessment of finger injury rehabilitation and for algorithms of precise control. Copyright © 2017 Elsevier Ltd. All rights reserved.

  19. Hand grip endurance test relates to clinical state and prognosis in COPD patients better than 6-minute walk test distance

    Directory of Open Access Journals (Sweden)

    Kovarik M

    2017-12-01

    Full Text Available Miroslav Kovarik,1,2 Vera Joskova,1,2 Anna Patkova,1,2 Vladimir Koblizek,3 Zdenek Zadak,2 Miloslav Hronek1,2 1Department of Biological and Medical Sciences, Faculty of Pharmacy in Hradec Kralove, Charles University, Hradec Kralove, Czech Republic; 2Department of Research and Development, University Hospital Hradec Kralove, Hradec Kralove, Czech Republic; 3Department of Pulmonary Medicine, University Hospital Hradec Kralove, Hradec Kralove, Czech Republic Purpose: Patients with COPD present peripheral muscle dysfunction and atrophy, expressed as muscle strength and endurance reduction. The goal of this study was direct dynamometric assessment of hand grip endurance and strength in relation to the stage of disease, multidimensional predictors of mortality, and 6-minute walk test (6MWT. To the best of our knowledge, there has been no previous study determining these parameters.Patients and methods: In this observational study, 58 consecutive outpatients with stable COPD and 25 volunteers without respiratory problems were compared. All COPD subjects underwent a comprehensive examination to determine COPD severity, prognostic scales, and 6MWT. Body composition, basic spirometric parameters, and hand grip strength and endurance were determined in all study participants.Results: Patients in the COPD group had a 15% decrease in maximum strength (P=0.012 and a 28% decrease in area under the force/time curve (AUC of the endurance test (P<0.001 compared to the control group. Dynamometric parameters were significantly negatively associated with the stage of disease and values of multivariable prediction indexes, and positively associated with the results of 6MWT. In most cases, closer associations were found with AUC than with 6MWT and in the gender-specific groups.Conclusion: Both hand grip strength and endurance are impaired in COPD patients in comparison with the control group. In particular, AUC could be considered as an attractive option not only to

  20. Performance of repetitive tasks induces decreased grip strength and increased fibrogenic proteins in skeletal muscle: role of force and inflammation.

    Directory of Open Access Journals (Sweden)

    Samir M Abdelmagid

    Full Text Available This study elucidates exposure-response relationships between performance of repetitive tasks, grip strength declines, and fibrogenic-related protein changes in muscles, and their link to inflammation. Specifically, we examined forearm flexor digitorum muscles for changes in connective tissue growth factor (CTGF; a matrix protein associated with fibrosis, collagen type I (Col1; a matrix component, and transforming growth factor beta 1 (TGFB1; an upstream modulator of CTGF and collagen, in rats performing one of two repetitive tasks, with or without anti-inflammatory drugs.To examine the roles of force versus repetition, rats performed either a high repetition negligible force food retrieval task (HRNF, or a high repetition high force handle-pulling task (HRHF, for up to 9 weeks, with results compared to trained only (TR-NF or TR-HF and normal control rats. Grip strength declined with both tasks, with the greatest declines in 9-week HRHF rats. Quantitative PCR (qPCR analyses of HRNF muscles showed increased expression of Col1 in weeks 3-9, and CTGF in weeks 6 and 9. Immunohistochemistry confirmed PCR results, and also showed greater increases of CTGF and collagen matrix in 9-week HRHF rats than 9-week HRNF rats. ELISA, and immunohistochemistry revealed greater increases of TGFB1 in TR-HF and 6-week HRHF, compared to 6-week HRNF rats. To examine the role of inflammation, results from 6-week HRHF rats were compared to rats receiving ibuprofen or anti-TNF-α treatment in HRHF weeks 4-6. Both treatments attenuated HRHF-induced increases in CTGF and fibrosis by 6 weeks of task performance. Ibuprofen attenuated TGFB1 increases and grip strength declines, matching our prior results with anti-TNFα.Performance of highly repetitive tasks was associated with force-dependent declines in grip strength and increased fibrogenic-related proteins in flexor digitorum muscles. These changes were attenuated, at least short-term, by anti-inflammatory treatments.

  1. Coming to Grips with Breast Cancer: The Spouse’s Experience with His Wife’s First Six Months

    OpenAIRE

    Zahlis, Ellen H.; Lewis, Frances M.

    2010-01-01

    This study examines the experiences of 48 spouses of wives newly diagnosed with local or regional breast cancer. Their reported experiences were organized into the core construct of Coming to Grips reflected by four domains: (1) Feeling nailed by the breast cancer; (2) Changing us; (3) Taking care of me; and (4) Making things work. Prior studies have underestimated the extent to which the assumptive world and day-to-day lives of spouses are shattered by the diagnosis of breast cancer and the ...

  2. A COMPARATIVE STUDY TO FIND OUT IMMEDIATE EFFECTIVENESS OF MOVEMENT WITH MOBILIZATION VERSUS ELBOW ORTHOSIS ON PAIN AND GRIP STRENGTH IN LATERAL EPICONDYLITIS IN HOUSEWIVES

    Directory of Open Access Journals (Sweden)

    Trishna Kakati

    2015-12-01

    Full Text Available Background: There are various studies using Mulligan’s MWM with or without combining with electrotherapy modalities and proved the efficacy of the technique in immediately decreasing pain and improving grip strength in patients with lateral epicondylitis. Orthotic as a treatment is also proved to be beneficial in decreasing pain and improving grip strength. There is evidence that housewives are prone to develop lateral epicondylitis due to their routine household work. But there is lack of evidence which compare initial effects of MWM and orthosis in housewives bringing up better outcome measures. The purpose of this study is to compare the initial effectiveness of Mulligan’s MWM and elbow orthosis on pain and grip strength in housewives with lateral epicondylitis. The aim of the study is to evaluate the effectiveness of Mulligan’s MWM technique versus counterforce elbow orthosis in immediately reducing pain and improving grip strength in lateral epicondylitis in housewives. Methodos: All subjects underwent a pre-treatment examination to assess pain and pain free hand grip strength with the help of outcome measures. Subjects were randomly assigned into two groups, A and B respectively; having 25 subjects in each group. Group A was treated with one session of Mulligan’s MWM technique. Group B was treated with Counterforce elbow strap orthosis. Data was assessed pre-treatment and immediately after treatment. Visual Analogue Scale (VAS and hand grip on Hand Grip Dynamometer (HGD were used as outcome measures. Results: Independent t-test was performed to see the effectiveness between Mulligan’s MWM and elbow orthosis. For VAS, t = - 2.243 which is significant at 5% level of significance. It has been inferred that VAS decreases more when Mulligan’s MWM was applied. For HGD, t = 0.878 which is not significant implying that increase in HGD do not differ remarkably for the two treatments. Conclusion: It has been recorded from the study that

  3. The bilateral movement condition facilitates maximal but not submaximal paretic-limb grip force in people with post-stroke hemiparesis

    Science.gov (United States)

    DeJong, Stacey L.; Lang, Catherine E.

    2012-01-01

    Objectives Although healthy individuals have less force production capacity during bilateral muscle contractions compared to unilateral efforts, emerging evidence suggests that certain aspects of paretic upper limb task performance after stroke may be enhanced by moving bilaterally instead of unilaterally. We investigated whether the bilateral movement condition affects grip force differently on the paretic side of people with post-stroke hemiparesis, compared to their non-paretic side and both sides of healthy young adults. Methods Within a single session, we compared: 1) maximal grip force during unilateral vs. bilateral contractions on each side, and 2) force contributed by each side during a 30% submaximal bilateral contraction. Results Healthy controls produced less grip force in the bilateral condition, regardless of side (- 2.4% difference), and similar findings were observed on the non-paretic side of people with hemiparesis (- 4.5% difference). On the paretic side, however, maximal grip force was increased by the bilateral condition in most participants (+11.3% difference, on average). During submaximal bilateral contractions in each group, the two sides each contributed the same percentage of unilateral maximal force. Conclusions The bilateral condition facilitates paretic limb grip force at maximal, but not submaximal levels. Significance In some people with post-stroke hemiparesis, the paretic limb may benefit from bilateral training with high force requirements. PMID:22248812

  4. The Effects of Counterforce Brace Size on the Wrist Range of Motility, Pain, Grip & Wrist Extension Sterngth in Normal Subjects and Patients with Tennis Elbow

    Directory of Open Access Journals (Sweden)

    Ali Asghar Jameh-Bozorgi

    2006-04-01

    Full Text Available Objective: Counter force brace is one of the most usefull treatments for lateral opicondylitis (Tennis elbow because it decreases grip pain and increases the power of grip, power of wrist extension and Wrist Range of Motility. The purpose of this quasi experimental (repeated measurementsstudy was to determine the effect of 3 counterforce brace sizes on the wrist R.O.M, grip and wrist extension strength and pain intensity in two groups of healthy subjects and patients with tennis elbow. Materials & Methods: 18 normal subjects & 18 patients with tennis elbow were selected simple conveniently and were tested with no brace and 3 size of counterforce (1,2 and 3 inches. The R.O.M , strength and pain intensity were measured by jamar goniometry and Nicholas MMT dynamometry & VAS, respectively. Results: 1 With all sizes there was a significant decrease of R.O.M on normal subjects but no significant difference in patients. 2 There was a significant decrease of grip strength with 1-inch brace in normal subjects but a significant increase of grip strength with 2 and 3-inch brace in patiens. 3 All sizes of brace caused significant decrease of extension strength in normal subjects but increase in patients. 4All size caused significant decrease of pain intensity that was more considerable in the case of 2 and 3 inch size. Conclusion: The results shows that the counterforce brace may be considered as an effective treatment for increasing strength and decreasing pain in patients with tennis elbow.

  5. A new classification for 'Pistol Grip Deformity'. Correlation between the severity of the deformity and the grade of osteoarthritis of the hip

    International Nuclear Information System (INIS)

    Ipach, Ingmar; Mittag, F.; Sachsenmaier, S.; Kluba, T.; Heinrich, P.

    2011-01-01

    Purpose: Two types of femoroacetabular impingement (FAI) are described as reasons for the early development of osteoarthritis of the hip. Cam impingement develops from contact between an abnormal head-neck junction and the acetabular rim. Pincer impingement is characterized by local or general overcoverage of the femoral head by the acetabular rim. Both forms might cause early osteoarthritis of the hip. A decreased head/neck offset has been recognized on AP pelvic views and labeled as 'pistol grip deformity'. The aim of the study was to develop a classification for this deformity with regard to the stage of osteoarthritis of the hip. Materials and Methods: 76 pelvic and axial views were analyzed for alpha angle and head ratio. 22 of them had a normal shape in the head-neck region and no osteoarthritis signs, 27 had a 'pistol grip deformity' and osteoarthritis I and 27 had a 'pistol grip deformity' and osteoarthritis II -IV . The CART method was used to develop a classification. Results: There was a statistically significant correlation between alpha angle and head ratio. A statistically significant difference in alpha angle and head ratio was seen between the three groups. Using the CART method, we developed a three-step classification system for the 'pistol grip deformity' with very high accuracy. This deformity was aggravated by increasing age. Conclusion: Using this model it is possible to differentiate between normal shapes of the head-neck junction and different severities of the pistol grip deformity. (orig.)

  6. Grounding by Attention Simulation in Peripersonal Space: Pupils Dilate to Pinch Grip But Not Big Size Nominal Classifier.

    Science.gov (United States)

    Lobben, Marit; Bochynska, Agata

    2018-03-01

    Grammatical categories represent implicit knowledge, and it is not known if such abstract linguistic knowledge can be continuously grounded in real-life experiences, nor is it known what types of mental states can be simulated. A former study showed that attention bias in peripersonal space (PPS) affects reaction times in grammatical congruency judgments of nominal classifiers, suggesting that simulated semantics may include reenactment of attention. In this study, we contrasted a Chinese nominal classifier used with nouns denoting pinch grip objects with a classifier for nouns with big object referents in a pupil dilation experiment. Twenty Chinese native speakers read grammatical and ungrammatical classifier-noun combinations and made grammaticality judgment while their pupillary responses were measured. It was found that their pupils dilated significantly more to the pinch grip classifier than to the big object classifier, indicating attention simulation in PPS. Pupil dilations were also significantly larger with congruent trials on the whole than in incongruent trials, but crucially, congruency and classifier semantics were independent of each other. No such effects were found in controls. Copyright © 2017 Cognitive Science Society, Inc.

  7. Analysis of the effects of hospitalization on fine hand functions compared to gross grip in patients with rheumatoid arthritis

    Directory of Open Access Journals (Sweden)

    Zeynep Tuna

    2015-09-01

    Full Text Available Objective: Hospitalization process causes a variety of physical problems. The decrease of hand use in daily life during hospitalization brings hand dysfunction to mind in inpatients. The aim of this study is to compare the hand functions of hospitalized patients with Rheumatoid Arthritis (RA to outpatients in detail. Methods: Grip and pinch strengths of both hospitalized patients in rheumatology service and outpatients on the routine control day were measured. In addition, 9-Hole Peg Test was performed and the disability level was determined by the Turkish version of Michigan Hand Outcomes Questionnaire (MHOQ. Results: While grip strength and MHOQ scores were similar (p>0.05 in both groups, all three pinch strengths (lateral, bipod, tripod and 9HPT scores were lower (p<0.05 in hospitalized patients. Conclusion: Consequently, besides disease activity, hospitalization process also impairs fine hand functions in rheumatological patients. Evaluation of fine hand functions and appropriate rehabilitative interventions may prevent further disability in hospitalized patients. J Clin Exp Invest 2015; 6 (3: 228-232

  8. Evaluation of finger A3 pulley rupture in the crimp grip position - a magnetic resonance imaging cadaver study

    Energy Technology Data Exchange (ETDEWEB)

    Bayer, Thomas; Uder, Michael; Janka, Rolf [University of Erlangen-Nuremberg, Department of Radiology, Erlangen (Germany); Adler, Werner [University of Erlangen-Nuremberg, Department of Biometry and Epidemiology, Erlangen (Germany); Schweizer, Andreas [Balgrist, University of Zurich, Department of Orthopaedics, Zurich (Switzerland); Schoeffl, Isabelle [Klinikum Bamberg, Department of Pediatrics, Bamberg (Germany)

    2015-09-15

    The correct diagnosis of an A3 pulley rupture is challenging for musculoskeletal radiologists. An A3 pulley rupture should in theory influence the shape of the proximal interphalangeal joint volar plate (VP) and the amount of bowstringing at level of the VP during finger flexion. The purpose of this study was to perform MRI with metric analysis of the VP configuration and VP bowstringing in cadaver fingers in the crimp grip position and to determine cut points for A3 pulley rupture. MRI in the crimp grip position was performed in 21 cadaver fingers with artificially created flexor tendon pulley tears (fingers with A3 pulley rupture n = 16, fingers without A3 pulley rupture n = 5). The distances of the translation of the VP relative to the middle phalanx base, the distances between the flexor tendons and the VP body, and the distances between the flexor tendon and bone (TB) were measured. Statistical analysis showed significantly lower VP translation distances and significantly higher VP tendon distances if the A3 pulley was ruptured. A2 TB and A4 TB distances did not differ significantly in specimens with and without A3 pulley rupture. The optimal cut points for A3 pulley rupture were a VP translation distance <2.8 mm and a VP tendon distance >1.4 mm. Reduction of the VP translation distance and augmentation of the VP tendon distance are suitable indirect signs of A3 pulley rupture. (orig.)

  9. Laterality and grip strength influence hand bone micro-architecture in modern humans, an HRpQCT study.

    Science.gov (United States)

    Reina, Nicolas; Cavaignac, Etienne; Trousdale, William H; Laffosse, Jean-Michel; Braga, José

    2017-06-01

    It is widely hypothesized that mechanical loading, specifically repetitive low-intensity tasks, influences the inner structure of cancellous bone. As such, there is likely a relationship between handedness and bone morphology. The aim of this study is to determine patterns in trabecular bone between dominant and non-dominant hands in modern humans. Seventeen healthy patients between 22 and 32 years old were included in the study. Radial carpal bones (lunate, capitate, scaphoid, trapezium, trapezoid, 1st, 2nd and 3rd metacarpals) were analyzed with high-resolution micro-computed tomography. Additionally, crush and pinch grip were recorded. Factorial analysis indicated that bone volume ratio, trabeculae number (Tb.N), bone surface to volume ratio (BS.BV), body weight, stature and crush grip were all positively correlated with principal components 1 and 2 explaining 78.7% of the variance. Volumetric and trabecular endostructural parameters (BV/TV, BS/BV or Tb.Th, Tb.N) explain the observed inter-individual variability better than anthropometric or clinical parameters. Factors analysis regressions showed correlations between these parameters and the dominant side for crush strength for the lunate (r 2 = 0.640, P modern human wrist. © 2017 Anatomical Society.

  10. New results on the relation between tyre-road longitudinal stiffness and maximum available grip for motor car

    Science.gov (United States)

    Andrieux, A.; Vandanjon, P. O.; Lengelle, R.; Chabanon, C.

    2010-12-01

    Tyre-road estimation methods have been the objective of many research programmes throughout the world. Most of these methods aim at estimating the friction components such as tyre longitudinal slip rate κ and friction coefficient μ in the contact patch area. In order to estimate the maximum available friction coefficient μmax, these methods generally use a probabilistic relationship between the grip obtained for low tyre excitations (such as constant speed driving) and the grip obtained for high tyre excitations (such as emergency braking manoeuvre). Confirmation or invalidation of this relationship from experimental results is the purpose of this paper. Experiments have been carried out on a reference track including several test boards corresponding to a wide textural spectrum. The main advantage of these experiments lies in the use of a vehicle allowing us to accurately build point-by-point relationship between κ and μ. This relationship has been determined for different tyres and pavement textures. Finally, the curves obtained are analysed to check the validity of the relationship between the current friction coefficient used by the car during normal driving conditions and μmax.

  11. Effect of Isometric Hand Grip Exercises on Blood Flow and Placement of IV Catheters for Administration of Chemotherapy.

    Science.gov (United States)

    Ozkaraman, Ayse; Yesilbalkan, Öznur Usta

    2016-04-01

    Complications may occur in the subcutaneous or subdermal tissues during IV administration of chemotherapy related to blood flow and catheter placement. Daily isometric hand grip exercises were evaluated for their effect on blood flow in the vessels of the nondominant arm before placement of IV catheters and the success rate of IV catheter placement on the first attempt. The study focused on patients with non-Hodgkin lymphoma receiving the first and second cycles of chemotherapy. The intervention group performed daily isometric hand grip exercises before chemotherapy with peripheral catheter insertion. The control group performed routine activities only. Blood flow was measured by ultrasound in the brachial artery (BA) and brachial vein (BV) of the nondominant arm before the first (T1) and second (T2) cycles of chemotherapy. Blood flow slightly increased in the intervention group at T2 compared to T1. In the control group, blood flow decreased in the BA and did not change in the BV at T2 compared to T1. The success rate for first-attempt placement of a peripheral IV catheter was the same for the intervention and control groups.

  12. Normative data for hand grip strength and key pinch strength, stratified by age and gender for a multiethnic Asian population.

    Science.gov (United States)

    Lam, Ngee Wei; Goh, Hui Ting; Kamaruzzaman, Shahrul Bahyah; Chin, Ai-Vyrn; Poi, Philip Jun Hua; Tan, Maw Pin

    2016-10-01

    Hand strength is a good indicator of physical fitness and frailty among the elderly. However, there are no published hand strength references for Malaysians aged > 65 years. This study aimed to establish normative data for hand grip strength (HGS) and key pinch strength (KPS) for Malaysians aged ≥ 60 years, and explore the relationship between hand strength and physical ability. Healthy participants aged ≥ 60 years with no neurological conditions were recruited from rural and urban locations in Malaysia. HGS and KPS were measured using hand grip and key pinch dynamometers. Basic demographic data, anthropometric measures, modified Barthel Index scores and results of the Functional Reach Test (FRT), Timed Up and Go (TUG) test and Jebsen-Taylor Hand Function Test (JTHFT) were recorded. 362 subjects aged 60-93 years were recruited. The men were significantly stronger than the women in both HGS and KPS (p Malaysia. Future studies are required to determine the modifiable factors for poor hand strength. Copyright: © Singapore Medical Association

  13. White matter organization in cervical spinal cord relates differently to age and control of grip force in healthy subjects.

    Science.gov (United States)

    Lindberg, Påvel G; Feydy, Antoine; Maier, Marc A

    2010-03-17

    Diffusion tensor imaging (DTI) can be used to elucidate relations between CNS structure and function. We hypothesized that the degree of spinal white matter organization relates to the accuracy of control of grip force. Healthy subjects of different age were studied using DTI and visuomotor tracking of precision grip force. The latter is a prime component of manual dexterity. A regional analysis of spinal white matter [fractional anisotropy (FA)] across multiple cervical levels (C2-C3, C4-C5, and C6-C7) and in different regions of interest (left and right lateral or medial spinal cord) was performed. FA was highest at the C2-C3 level, higher on the right than the left side, and higher in the lateral than in the medial spinal cord (p level in the lateral spinal cord, in which the corticospinal tract innervates spinal circuitry controlling hand and digit muscles. FA of the medial spinal cord correlated consistently with age across all cervical levels, whereas FA of the lateral spinal cord did not. The results suggest (1) a functionally relevant specialization of lateral spinal cord white matter and (2) an increased sensitivity to age-related decline in medial spinal cord white matter in healthy subjects.

  14. Associations Between Diabetes and Both Cardiovascular Disease and All-Cause Mortality Are Modified by Grip Strength: Evidence From UK Biobank, a Prospective Population-Based Cohort Study.

    Science.gov (United States)

    Celis-Morales, Carlos A; Petermann, Fanny; Hui, Li; Lyall, Donald M; Iliodromiti, Stamatina; McLaren, James; Anderson, Jana; Welsh, Paul; Mackay, Daniel F; Pell, Jill P; Sattar, Naveed; Gill, Jason M R; Gray, Stuart R

    2017-12-01

    Grip strength and diabetes are predictors of mortality and cardiovascular disease (CVD), but whether these risk factors interact to predispose to adverse health outcomes is unknown. This study determined the interactions between diabetes and grip strength and their association with health outcomes. We undertook a prospective, general population cohort study by using UK Biobank. Cox proportional hazards models were used to explore the associations between both grip strength and diabetes and the outcomes of all-cause mortality and CVD incidence/mortality as well as to test for interactions between diabetes and grip strength. A total of 347,130 UK Biobank participants with full data available (mean age 55.9 years, BMI 27.2 kg/m 2 , 54.2% women) were included in the analysis, of which 13,373 (4.0%) had diabetes. Over a median follow-up of 4.9 years (range 3.3-7.8 years), 6,209 died (594 as a result of CVD), and 4,301 developed CVD. Participants with diabetes were at higher risk of all-cause and CVD mortality and CVD incidence. Significant interactions ( P strength. Similar results were observed for all-cause mortality and CVD incidence. Risk of adverse health outcomes among people with diabetes is lower in those with high grip strength. Low grip strength may be useful to identify a higher-risk subgroup of patients with diabetes. Intervention studies are required to determine whether resistance exercise can reduce risk. © 2017 by the American Diabetes Association.

  15. The Effect of Two Different Hand Exercises on Grip Strength, Forearm Circumference, and Vascular Maturation in Patients Who Underwent Arteriovenous Fistula Surgery

    Science.gov (United States)

    Kong, Sangwon; Lee, Kyung Soo; Kim, Junho

    2014-01-01

    Objective To compare the effect of two different hand exercises on hand strength and vascular maturation in patients who underwent arteriovenous fistula surgery. Methods We recruited 18 patients who had chronic kidney disease and had undergone arteriovenous fistula surgery for hemodialysis. After the surgery, 10 subjects performed hand-squeezing exercise with GD Grip, and other 8 subjects used Soft Ball. The subjects continued the exercises for 4 weeks. The hand grip strength, pinch strength (tip, palmar and lateral pinch), and forearm circumference of the subjects were assessed before and after the hand-squeezing exercise. The cephalic vein size, blood flow velocity and volume were also measured by ultrasonography in the operated limb. Results All of the 3 types of pinch strengths, grip strength, and forearm circumference were significantly increased in the group using GD Grip. Cephalic vein size and blood flow volume were also significantly increased. However, blood flow velocity showed no difference after the exercise. The group using Soft Ball showed a significant increase in the tip and lateral pinch strength and forearm circumference. The cephalic vein size and blood flow volume were also significantly increased. On comparing the effect of the two different hand exercises, hand-squeezing exercise with GD Grip had a significantly better effect on the tip and palmar pinch strength than hand-squeezing exercise with Soft Ball. The effect on cephalic vein size was not significantly different between the two groups. Conclusion The results showed that hand squeezing exercise with GD Grip was more effective in increasing the tip and palmar pinch strength compared to hand squeezing exercise with soft ball. PMID:25379494

  16. Sex Differences in the Level and Rate of Change of Physical Function and Grip Strength in the Danish 1905-Cohort Study

    DEFF Research Database (Denmark)

    Oksuzyan, Anna; Maier, Heiner; McGue, Matt

    2010-01-01

    OBJECTIVE: The study was conducted to examine sex differences in the initial level and rate of change in physical function and grip strength. METHOD: The baseline survey included 2,262 Danes born in 1905 and alive in 1998 and followed-up in 2000, 2003, and 2005. Hence, the authors fully used...... the power of having a cohort with multiple assessments in late life and virtually complete follow-up of lifespan (through December 2008). Latent growth curve modeling was used. RESULTS: Men had higher initial levels and rates of decline in strength score and grip strength. Lifespan was positively correlated...

  17. Criterion-Referenced Values of Grip Strength and Usual Gait Speed Using Instrumental Activities of Daily Living Disability as the Criterion.

    Science.gov (United States)

    Lee, Meng-Chih; Hsu, Chih-Cheng; Tsai, Yi-Fen; Chen, Ching-Yu; Lin, Cheng-Chieh; Wang, Ching-Yi

    Current evidence suggests that grip strength and usual gait speed (UGS) are important predictors of instrumental activities of daily living (IADL) disability. Knowing the optimum cut points of these tests for discriminating people with and without IADL disability could help clinicians or researchers to better interpret the test results and make medical decisions. The purpose of this study was to determine the cutoff values of grip strength and UGS for best discriminating community-dwelling older adults with and without IADL disability, separately for men and women, and to investigate their association with IADL disability. We conducted secondary data analysis on a national dataset collected in the Sarcopenia and Translational Aging Research in Taiwan (START). The data used in this study consisted of health data of 2420 community-dwelling older adults 65 years and older with no history of stroke and with complete data. IADL disability was defined as at least 1 IADL item scored as "need help" or "unable to perform." Receiver operating characteristics analysis was used to estimate the optimum grip strength and UGS cut points for best discriminating older adults with/without IADL disability. The association between each physical performance (grip strength and UGS) and IADL disability was assessed with odds ratios (ORs). With IADL disability as the criterion, the optimal cutoff values of grip strength were 28.7 kg for men and 16.0 kg for women, and those for UGS were 0.76 m/s for men and 0.66 m/s for women. The grip strength test showed satisfactory discriminant validity (area under the curve > 0.7) in men and a strong association with IADL disability (OR > 4). Our cut points using IADL disability as the criterion were close to those indicating frailty or sarcopenia. Our reported cutoffs can serve as criterion-referenced values, along with those previously determined using different indicators, and provide important landmarks on the performance continua of older adults

  18. Medial Elbow Joint Space Increases With Valgus Stress and Decreases When Cued to Perform A Maximal Grip Contraction.

    Science.gov (United States)

    Pexa, Brett S; Ryan, Eric D; Myers, Joseph B

    2018-04-01

    Previous research indicates that the amount of valgus torque placed on the elbow joint during overhead throwing is higher than the medial ulnar collateral ligament (UCL) can tolerate. Wrist and finger flexor muscle activity is hypothesized to make up for this difference, and in vitro studies that simulated activity of upper extremity musculature, specifically the flexor digitorum superficialis and flexor carpi ulnaris, support this hypothesis. To assess the medial elbow joint space at rest, under valgus stress, and under valgus stress with finger and forearm flexor contraction by use of ultrasonography in vivo. Controlled laboratory study. Participants were 22 healthy males with no history of elbow dislocation or UCL injury (age, 21.25 ± 1.58 years; height, 1.80 ± 0.08 m; weight, 79.43 ± 18.50 kg). Medial elbow joint space was measured by use of ultrasonography during 3 separate conditions: at rest (unloaded), under valgus load (loaded), and with a maximal grip contraction under a valgus load (loaded-contracted) in both limbs. Participants lay supine with their arm abducted 90° and elbow flexed 30° with the forearm in full supination. A handgrip dynamometer was placed in the participants' hand to grip against during the contracted condition. Images were reduced in ImageJ to assess medial elbow joint space. A 2-way (condition × limb) repeated-measures analysis of variance and Cohen's d effect sizes were used to assess changes in medial elbow joint space. Post hoc testing was performed with a Bonferroni adjustment to assess changes within limb and condition. The medial elbow joint space was significantly larger in the loaded condition (4.91 ± 1.16 mm) compared with the unloaded condition (4.26 ± 1.23 mm, P space increases under a valgus load and then decreases when a maximal grip contraction is performed. This indicates that wrist and finger flexor muscle contraction may assist in limiting medial elbow joint space, a result similar to findings of previous

  19. Light-Absorbing Aerosol during NASA GRIP: Overview of Observations in the Free Troposphere and Associated with Tropical Storm Systems

    Science.gov (United States)

    Ziemba, L. D.; Beyersdorf, A. J.; Chen, G.; Corr, C. A.; Craig, L.; Dhaniyala, S.; Dibb, J. E.; Hudgins, C. H.; Ismail, S.; Latham, T.; Nenes, A.; Thornhill, K. L.; Winstead, E.; Anderson, B. E.

    2010-12-01

    Aerosols play a significant role in regulating Earth’s climate. Absorbing aerosols typically constitute a small fraction of ambient particle mass but can contribute significantly to direct and indirect climate forcing depending on size, mixing state, concentration, chemical composition, and vertical and spatial distribution. Aerosols may also significantly affect tropical storm/hurricane dynamics through direct light absorption and activation as cloud nuclei. An extensive suite of instrumentation measuring aerosol chemical, physical, and optical properties was deployed aboard the NASA DC-8 to characterize aerosol during the NASA GRIP (Genesis and Rapid Intensification Processes; August-September 2010) mission. The majority of flight time was spent at high altitude (greater than 9 km) and thus much of the sampling was done in the free troposphere, including extensive sampling in the vicinity of tropical storm systems and more diffuse cirrus clouds. With operations based in Fort Lauderdale, FL and St. Croix, U.S. Virgin Islands, a large geographic region was sampled including much of the Gulf of Mexico and tropical Atlantic Ocean. Observations are reported for light-absorbing carbon aerosol (mainly black carbon, BC) primarily using a single particle soot photometer (SP2). The SP2 employs single-particle laser-induced incandescence to provide a mass-specific measurement not subject to scattering interference that is optimal for the low concentration environments like those encountered during GRIP. BC mass concentrations, 100-500 nm size distributions, and mixing state (i.e. coating thickness of scattering material) are presented. Total and sub-micron aerosol absorption coefficients (principally from BC and dust aerosol) are reported using a particle soot absorption photometer (PSAP) along with comparisons with calculated absorption coefficients derived from SP2 observations in various conditions. In addition, dust aerosol is specifically identified using optical and

  20. Management of displaced inferior patellar pole fractures with modified tension band technique combined with cable cerclage using Cable Grip System.

    Science.gov (United States)

    Yang, Xu; Wu, Qinfen; Lai, Chin-Hui; Wang, Xin

    2017-10-01

    We present a modified tension band technique combined with cable cerclage using Cable Grip System for the treatment of displaced inferior patellar pole fractures and report the knee functional outcome. The patients who had had operative treatment of a displaced inferior patellar pole fracture (AO/OTA 34-A1) between December 2013 and December 2015 were studied retrospectively. Eleven consecutive patients had had open reduction and internal fixation with the modified technique using Cable Grip System, of whom, five males and six females with an average age of 60.9 years (range, 29-81 years). All fractures occurred from direct fall onto the knee. The average time from injury to surgery was 6.1days (range, 2-12days). The range of motion (ROM) was measured in degrees by goniometry at postoperative intervals of 1, 2, 4, 12, and 48 weeks; Knee function was evaluated using the Rasmussen scores at final follow-up. No patients had nonunion, loss of reduction, migration of wire, irritation from the implant and fixation breakage during the follow-up period. Recovery of ROM was achieved at 12 weeks, with the average ROM at 1 week was 72° (range, 65°-78°), 86.4° (range, 78°-92°) at 2 weeks, 115.5° (range, 103°-122°) at 4 weeks, 129.6° (range, 122°-133°) at 12 weeks, 134.5° (range, 129°-139°) at 48 weeks after the operation. Concerning the knee function outcome assessment, all patients showed excellent results at final follow-up. The average Rasmussen scores was 27.9 out of 30 (range, 27-29). The modified tension band technique combined with cable cerclage using Cable Grip System for displaced inferior patellar pole fractures can provide stable fixation with excellent results in knee function, allows for immediate mobilization and early weight-bearing, which is a simple and valuable technique in routine clinical practice. Copyright © 2017 Elsevier Ltd. All rights reserved.

  1. Influence Of The Gripping Fixture On The Modified Compact Tension Test Results: Evaluation Of The Experiments On Cylindrical Concrete Specimens

    Directory of Open Access Journals (Sweden)

    Holušová Táňa

    2015-12-01

    Full Text Available The modified compact tension test (MCT might become in the future a stable test configuration for the evaluation of fracture-mechanics parameters or also for description of fatigue behavior of composites materials such as concrete. Core drilling is used for sampling of existing structures. These samples have cylindrical shape with the selected thickness to avoid the stress concentration. This contribution focuses on the evaluation of the fracture behavior during static and quasi static tests. Static tests are performed on standard specimen with diameter 150 mm and length 300 mm. The quasi-static tests are performed using two different gripping fixtures. The results for quasi-static tests are represented as L-COD diagrams (i.e. load vs. crack opening displacement measured on the loading axis. The comparison of results and discussion of advantages and disadvantages are introduced.

  2. Is salivary cortisol moderating the relationship between salivary testosterone and hand-grip strength in healthy men?

    Science.gov (United States)

    Crewther, Blair T; Thomas, Andrew G; Stewart-Williams, Steve; Kilduff, Liam P; Cook, Christian J

    2017-03-01

    This study examined the moderating effect of cortisol (C) on the relationship between testosterone (T) and hand-grip strength (HGS) in healthy young men. Sixty-five males were monitored for salivary T, C and HGS before and 15 min after a short bout (5 × 6-s trials) of sprint cycling exercise. Sprint exercise promoted (p moderating variable. The pre-test combination of high C and low T levels favoured absolute HGS, whereas low pre-test C levels and a smaller T change were linked to larger HGS changes. These associations suggest that, in the current format, T is not necessarily anabolic to muscle strength in healthy young men. Such complexities could also explain some of the inconsistent T relationships with physical performance in lesser trained male populations.

  3. Grip force and heart rate responses to manual carrying tasks: effects of material, weight, and base area of the container.

    Science.gov (United States)

    Lee, Tzu-Hsien; Tseng, Chia-Yun

    2014-01-01

    This study recruited 16 industrial workers to examine the effects of material, weight, and base area of container on reduction of grip force (ΔGF) and heart rate for a 100-m manual carrying task. This study examined 2 carrying materials (iron and water), 4 carrying weights (4.4, 8.9, 13.3, 17.8 kg), and 2 base areas of container (24 × 24 cm, 35 × 24 cm). This study showed that carrying water significantly increased ΔGF and heart rate as compared with carrying iron. Also, ΔGF and heart rate significantly increased with carrying weight and base area of container. The effects of base area of container on ΔGF and heart rate were greater in carrying water condition than in carrying iron condition. The maximum dynamic effect of water on ΔGF and heart rate occurred when water occupied ~60%-80% of full volume of the container.

  4. Associations of work activities requiring pinch or hand grip or exposure to hand-arm vibration with finger and wrist osteoarthritis

    DEFF Research Database (Denmark)

    Hammer, Paula E C; Shiri, Rahman; Kryger, Ann I

    2014-01-01

    OBJECTIVE: We systematically reviewed the epidemiologic evidence linking finger and wrist osteoarthritis (OA) with work activities requiring pinch or hand grip or exposure to hand-arm vibration (HAV). METHODS: PubMed and Embase databases were searched up to June 2013. We selected studies assessing...

  5. Altered visual strategies and attention are related to increased force fluctuations during a pinch grip task in older adults.

    Science.gov (United States)

    Keenan, Kevin G; Huddleston, Wendy E; Ernest, Bradley E

    2017-11-01

    The purpose of the study was to determine the visual strategies used by older adults during a pinch grip task and to assess the relations between visual strategy, deficits in attention, and increased force fluctuations in older adults. Eye movements of 23 older adults (>65 yr) were monitored during a low-force pinch grip task while subjects viewed three common visual feedback displays. Performance on the Grooved Pegboard test and an attention task (which required no concurrent hand movements) was also measured. Visual strategies varied across subjects and depended on the type of visual feedback provided to the subjects. First, while viewing a high-gain compensatory feedback display (horizontal bar moving up and down with force), 9 of 23 older subjects adopted a strategy of performing saccades during the task, which resulted in 2.5 times greater force fluctuations in those that exhibited saccades compared with those who maintained fixation near the target line. Second, during pursuit feedback displays (force trace moving left to right across screen and up and down with force), all subjects exhibited multiple saccades, and increased force fluctuations were associated ( r s = 0.6; P = 0.002) with fewer saccades during the pursuit task. Also, decreased low-frequency (attention z scores. Comparison of these results with our previously published results in young subjects indicates that saccadic eye movements and attention are related to force control in older adults. NEW & NOTEWORTHY The significant contributions of the study are the addition of eye movement data and an attention task to explain differences in hand motor control across different visual displays in older adults. Older participants used different visual strategies across varying feedback displays, and saccadic eye movements were related with motor performance. In addition, those older individuals with deficits in attention had impaired motor performance on two different hand motor control tasks, including

  6. The glacial inception as recorded in the NorthGRIP Greenland ice core: timing, structure and associated abrupt temperature changes

    Energy Technology Data Exchange (ETDEWEB)

    Landais, Amaelle [UMR CEA-CNRS, CEA Saclay, IPSL/Laboratoire des Sciences du Climat et de l' Environnement, Gif-sur -Yvette (France); Hebrew University, Institute of Earth Sciences, Givat Ram, Jerusalem (Israel); Masson-Delmotte, Valerie; Jouzel, Jean; Minster, Benedicte [UMR CEA-CNRS, CEA Saclay, IPSL/Laboratoire des Sciences du Climat et de l' Environnement, Gif-sur -Yvette (France); Raynaud, Dominique [LGGE, UMR CNRS-UJF, St Martin d' Heres (France); Johnsen, Sigfus [University of Copenhagen, Department of Geophysics, Copenhagen (Denmark); Huber, Christof; Leuenberger, Markus; Schwander, Jakob [University of Bern, Physics Institute, Bern (Switzerland)

    2006-02-01

    The mechanisms involved in the glacial inception are still poorly constrained due to a lack of high resolution and cross-dated climate records at various locations. Using air isotopic measurements in the recently drilled NorthGRIP ice core, we show that no evidence exists for stratigraphic disturbance of the climate record of the last glacial inception ({proportional_to}123-100 kyears BP) encompassing Dansgaard-Oeschger events (DO) 25, 24 and 23, even if we lack sufficient resolution to completely rule out disturbance over DO 25. We quantify the rapid surface temperature variability over DO 23 and 24 with associated warmings of 10{+-}2.5 and 16{+-}2.5 C, amplitudes which mimic those observed in full glacial conditions. We use records of {delta}{sup 18}O of O{sub 2} to propose a common timescale for the NorthGRIP and the Antarctic Vostok ice cores, with a maximum uncertainty of 2,500 years, and to examine the interhemispheric sequence of events over this period. After a synchronous North-South temperature decrease, the onset of rapid events is triggered in the North through DO 25. As for later events, DO 24 and 23 have a clear Antarctic counterpart which does not seem to be the case for the very first abrupt warming (DO 25). This information, when added to intermediate levels of CO{sub 2} and to the absence of clear ice rafting associated with DO 25, highlights the uniqueness of this first event, while DO 24 and 23 appear similar to typical full glacial DO events. (orig.)

  7. Grip Force and 3D Push-Pull Force Estimation Based on sEMG and GRNN

    Directory of Open Access Journals (Sweden)

    Changcheng Wu

    2017-06-01

    Full Text Available The estimation of the grip force and the 3D push-pull force (push and pull force in the three dimension space from the electromyogram (EMG signal is of great importance in the dexterous control of the EMG prosthetic hand. In this paper, an action force estimation method which is based on the eight channels of the surface EMG (sEMG and the Generalized Regression Neural Network (GRNN is proposed to meet the requirements of the force control of the intelligent EMG prosthetic hand. Firstly, the experimental platform, the acquisition of the sEMG, the feature extraction of the sEMG and the construction of GRNN are described. Then, the multi-channels of the sEMG when the hand is moving are captured by the EMG sensors attached on eight different positions of the arm skin surface. Meanwhile, a grip force sensor and a three dimension force sensor are adopted to measure the output force of the human's hand. The characteristic matrix of the sEMG and the force signals are used to construct the GRNN. The mean absolute value and the root mean square of the estimation errors, the correlation coefficients between the actual force and the estimated force are employed to assess the accuracy of the estimation. Analysis of variance (ANOVA is also employed to test the difference of the force estimation. The experiments are implemented to verify the effectiveness of the proposed estimation method and the results show that the output force of the human's hand can be correctly estimated by using sEMG and GRNN method.

  8. Application of Quality Function Deployment (QFD) method and kano model to redesign fresh fruit bunches sorting tool

    Science.gov (United States)

    Anizar; Siregar, I.; Yahya, I.; Yesika, N.

    2018-02-01

    The activity of lowering fresh fruit bunches (FFB) from truck to sorting floor is performed manually by workers using a sorting tool. Previously, the sorting tool used is a pointed iron bar with a T-shaped handle. Changes made to the sorting tool causes several complaints on worker and affect the time to lower the fruit. The purpose of this article is to obtain the design of an FFB sorting tool that suits the needs of these workers by applying the Quality Function Deployment (QFD) and Kano Model methods. Both of the two methods will be integrated to find the design that matches workers’ image and psychological feeling. The main parameters are to obtain the customer requirements of the palm fruit loading workers, to find the most important technical characteristics and critical part affecting the quality of the FFB sorting tool. The customer requirements of the palm loading workers are the following : the color of the coating paint is gray, the bar material is made of stainless pipe, the main grip coating material is made of grip, the tip material is made of the spring steel, the additional grip is made of rubber and the handle is of triangular shape.

  9. Bilateral deficits in fine motor control and pinch grip force are not associated with electrodiagnostic findings in women with carpal tunnel syndrome.

    Science.gov (United States)

    de la Llave-Rincón, Ana Isabel; Fernández-de-Las-Peñas, César; Pérez-de-Heredia-Torres, Marta; Martínez-Perez, Almudena; Valenza, Marie Carmen; Pareja, Juan A

    2011-06-01

    : The aim of this study was to analyze the differences in deficits in fine motor control and pinch grip force between patients with minimal, moderate/mild, or severe carpal tunnel syndrome (CTS) and healthy age- and hand dominance-matched controls. : A case-control study was conducted. The subtests of the Purdue Pegboard Test (one-hand and bilateral pin placements and assemblies) and pinch grip force between the thumb and the remaining four fingers of the hand were bilaterally evaluated in 66 women with minimal (n = 16), moderate (n = 16), or severe (n = 34) CTS and in 20 age- and hand-matched healthy women. The differences among the groups were analyzed using different mixed models of analysis of variance. : A two-way mixed analysis of variance revealed significant differences between groups, not depending on the presence of unilateral or bilateral symptoms (side), for the one-hand pin placement subtest: patients showed bilateral lower scores compared with controls (P < 0.001), without differences among those with minimal, moderate, or severe CTS (P = 0.946). The patients also exhibited lower scores in bilateral pin placement (P < 0.001) and assembly (P < 0.001) subtests, without differences among them. The three-way analysis of variance revealed significant differences among groups (P < 0.001) and fingers (P < 0.001), not depending on the presence of unilateral/bilateral symptoms (P = 0.684), for pinch grip force: patients showed bilateral lower pinch grip force in all fingers compared with healthy controls, without differences among those with minimal, moderate, or severe CTS. : The current study revealed similar bilateral deficits in fine motor control and pinch grip force in patients with minimal, moderate, or severe CTS, supporting that fine motor control deficits are a common feature of CTS not associated with electrodiagnostic findings.

  10. The variability of the isotopic signal during the last Glacial as seen from the ultra-high resolution NEEM and NorthGRIP ice cores.

    Science.gov (United States)

    Gkinis, Vasileios; Møllesøe Vinther, Bo; Terkelsen Holme, Christian; Capron, Emilie; Popp, Trevor James; Olander Rasmussen, Sune

    2017-04-01

    The continuity and high resolution available in polar ice core records constitutes them an excellent tool for the study of the stadial-interstadial transitions, notably through the study of the water isotopic composition of polar precipitation (δ18O, δD ). The quest for the highest resolution possible has resulted in experimental sampling and analysis techniques that have yielded data sets with a potential to change the current picture on the climatic signals of the last Glacial. Specifically, the ultra-high resolution δ18O signals from the NorthGRIP and NEEM ice cores, present a variability at multi-annual and decadal time scales, whose interpretation gives rise to further puzzling though interesting questions and an obvious paradox. By means of simple firn isotope diffusion and densification calculations, we firstly demonstrate that the variability of observed signals is unlikely to be due to post depositional effects that are known to occur on the surface of the Greenland ice cap and alter the δ18O composition of the precipitated snow. Assuming specific values for the δ18O sensitivity to temperature (commonly referred to as the δ18O slope), we estimate that the temperature signal during the stadials has a variability that extents from interstadial to extremely cold levels with peak-to-peak fluctuations of almost 35 K occurring in a few years. Similarly, during interstadial phases the temperature varies rapidly from stadial to Holocene levels while the signal variability shows a maximum during the LGM, with magnitudes of up to 15‰ that translate to ≈ 50 K when a δ18O slope of 0.3‰K-1 is used. We assess the validity of these results and comment on the stability of the δ18O slope. Driven by a simple logical queue, we conclude that the observed δ18O variability reflects a climatic signal although not necessarily attributed 100% to temperature changes. From this we can assume that there occur climatic mechanisms during the previously thought stable

  11. Study of the effects of the hand grip and finger strengths on the friction and petrissage - the massage manipulations - of the students who take massage courses: Kütahya City example

    Directory of Open Access Journals (Sweden)

    Erzeybek Mustafa Said

    2016-01-01

    Full Text Available In this research, the effect of the hand grip and finger strengths on the power development between the friction and petrissage techniques - the massage manipulations - have been studied. To the study that has been structured as a single group pretest/post test, 36 healthy males who are the students of the University of Dumlupınar, Academy of Physical Education and Sports and who take massage courses (age = 19.72 ± 1.56 years (average ± Sd have been included. The practical massage course has continued for 12 weeks, two days a week for a total of one hour and the hand grip strength of both hands (right hand grip strength = RHG, left hand grip strength = LHG and the grip strength of both fingers (right finger strength = RF, left finger strength = LF have been recorded at the beginning. For the measurements carried out before and later of the study with regard to the hand grip strength, a Takkei branded hand dynamometer and with regard to the finger grip strength a (baseline branded pinch meter have been used. All measurements have been repeated twice and for the analysis, the average values obtained from two deads have been used. For statistical analysis, with regard to the changes in the pre test-post test finger strength and hand grip strength, paired-samples t test has been used. The significance limit has been defined as p0.05. It is possible to report that massaging regularly with both hands is efficient for the development of the finger and hand grip strengths; especially, with regard to the friction (circular movements that are generally carried out with fingers and petrissage (kneading that is generally carried out with the palm techniques.

  12. Simulation tools

    CERN Document Server

    Jenni, F

    2006-01-01

    In the last two decades, simulation tools made a significant contribution to the great progress in development of power electronics. Time to market was shortened and development costs were reduced drastically. Falling costs, as well as improved speed and precision, opened new fields of application. Today, continuous and switched circuits can be mixed. A comfortable number of powerful simulation tools is available. The users have to choose the best suitable for their application. Here a simple rule applies: The best available simulation tool is the tool the user is already used to (provided, it can solve the task). Abilities, speed, user friendliness and other features are continuously being improved—even though they are already powerful and comfortable. This paper aims at giving the reader an insight into the simulation of power electronics. Starting with a short description of the fundamentals of a simulation tool as well as properties of tools, several tools are presented. Starting with simplified models ...

  13. The SAO and Kelvin waves in the EuroGRIPS GCMS and the UK Met. Office analyses

    Directory of Open Access Journals (Sweden)

    M. Amodei

    Full Text Available We compare the tropical oscillations and planetary scale Kelvin waves in four troposphere-stratosphere climate models and the assimilated dataset produced by the United Kingdom Meteorological Office (UKMO. The comparison has been made in the GRIPS framework "GCM-Reality Intercomparison Project for SPARC", where SPARC is Stratospheric Processes and their Role in Climate, a project of the World Climate Research Program. The four models evaluated are European members of GRIPS: the UKMO Unified Model (UM, the model of the Free University in Berlin (FUB–GCM, the ARPEGE-climat model of the French National Centre for Meteorological Research (CNRM, and the Extended UGAMP GCM (EUGCM of the Centre for Global Atmospheric Modelling (CGAM. The integrations were performed with different, but annually periodic external conditions (e.g., sea-surface temperature, sea ice, and incoming solar radiation. The structure of the tropical winds and the strengths of the Kelvin waves are examined. In the analyses where the SAO (Semi-Annual Oscillation and the QBO (Quasi-Biennal Oscillation are reasonably well captured, the amplitude of these analysed Kelvin waves is close to that observed in independent data from UARS (Upper Atmosphere Research Satellite. In agreement with observations, the Kelvin waves generated in the models propagate into the middle atmosphere as wave packets, consistent with a convective forcing origin. In three of the models, slow Kelvin waves propagate too high and their amplitudes are overestimated in the upper stratosphere and in the mesosphere, the exception is the UM which has weaker waves. None of the modelled waves are sufficient to force realistic eastward phases of the QBO or SAO. Although the SAO is represented by all models, only two of them are able to generate westerlies between 10 hPa and 50 hPa. The importance of the role played in the SAO by unresolved gravity waves is emphasized. Although it exhibits some unrealistic features, the

  14. The SAO and Kelvin waves in the EuroGRIPS GCMS and the UK Met. Office analyses

    Directory of Open Access Journals (Sweden)

    M. Amodei

    2001-01-01

    Full Text Available We compare the tropical oscillations and planetary scale Kelvin waves in four troposphere-stratosphere climate models and the assimilated dataset produced by the United Kingdom Meteorological Office (UKMO. The comparison has been made in the GRIPS framework "GCM-Reality Intercomparison Project for SPARC", where SPARC is Stratospheric Processes and their Role in Climate, a project of the World Climate Research Program. The four models evaluated are European members of GRIPS: the UKMO Unified Model (UM, the model of the Free University in Berlin (FUB–GCM, the ARPEGE-climat model of the French National Centre for Meteorological Research (CNRM, and the Extended UGAMP GCM (EUGCM of the Centre for Global Atmospheric Modelling (CGAM. The integrations were performed with different, but annually periodic external conditions (e.g., sea-surface temperature, sea ice, and incoming solar radiation. The structure of the tropical winds and the strengths of the Kelvin waves are examined. In the analyses where the SAO (Semi-Annual Oscillation and the QBO (Quasi-Biennal Oscillation are reasonably well captured, the amplitude of these analysed Kelvin waves is close to that observed in independent data from UARS (Upper Atmosphere Research Satellite. In agreement with observations, the Kelvin waves generated in the models propagate into the middle atmosphere as wave packets, consistent with a convective forcing origin. In three of the models, slow Kelvin waves propagate too high and their amplitudes are overestimated in the upper stratosphere and in the mesosphere, the exception is the UM which has weaker waves. None of the modelled waves are sufficient to force realistic eastward phases of the QBO or SAO. Although the SAO is represented by all models, only two of them are able to generate westerlies between 10 hPa and 50 hPa. The importance of the role played in the SAO by unresolved gravity waves is emphasized. Although it exhibits some unrealistic features, the

  15. A stability tool for use within TELEGRIP

    International Nuclear Information System (INIS)

    Son, W.H.; Trinkle, J.C.

    1998-12-01

    During the assembly of a product, it is vital that the partially-completed assembly be stable. To guarantee this, one must ensure that contacts among the parts and the fixtures are sufficient to stabilize the assembly. Thus, it would be desirable to have an efficient method for testing an assembly stability, and, if this is not possible, generating a set of additional fixture contact points, known as fixels, that will stabilize it. One can apply this method to the situation of safe handling of special nuclear material (SNM). To have these functionalities should help improve the safety and enhance the performance of special nuclear material (SNM) handling and storage operations, since some methods are needed for gripping objects in a stable manner. Also, one may need a way to find a pit-holding fixture inserted into containers. In this paper, the authors present a stability tool, which they call Stab Tool, which was developed to test the stability of objects grasped by robotic hands, objects placed in fixtures, or sets of objects piled randomly on top of one another. Stab Tool runs on top of a commercial software package, TELEGRIP, which is used for geometry modeling and motion creation. The successful development of the stability depends strongly on TELEGRIP's ability to compute the distances between pairs of three-dimensional bodies in the simulated environment. The interbody distance computation tool takes advantage of the polyhedral representations of bodies used by TELEGRIP and of linear programming techniques to yield an efficient algorithm

  16. Actin grips: circular actin-rich cytoskeletal structures that mediate the wrapping of polymeric microfibers by endothelial cells.

    Science.gov (United States)

    Jones, Desiree; Park, DoYoung; Anghelina, Mirela; Pécot, Thierry; Machiraju, Raghu; Xue, Ruipeng; Lannutti, John J; Thomas, Jessica; Cole, Sara L; Moldovan, Leni; Moldovan, Nicanor I

    2015-06-01

    Interaction of endothelial-lineage cells with three-dimensional substrates was much less studied than that with flat culture surfaces. We investigated the in vitro attachment of both mature endothelial cells (ECs) and of less differentiated EC colony-forming cells to poly-ε-capro-lactone (PCL) fibers with diameters in 5-20 μm range ('scaffold microfibers', SMFs). We found that notwithstanding the poor intrinsic adhesiveness to PCL, both cell types completely wrapped the SMFs after long-term cultivation, thus attaining a cylindrical morphology. In this system, both EC types grew vigorously for more than a week and became increasingly more differentiated, as shown by multiplexed gene expression. Three-dimensional reconstructions from multiphoton confocal microscopy images using custom software showed that the filamentous (F) actin bundles took a conspicuous ring-like organization around the SMFs. Unlike the classical F-actin-containing stress fibers, these rings were not associated with either focal adhesions or intermediate filaments. We also demonstrated that plasma membrane boundaries adjacent to these circular cytoskeletal structures were tightly yet dynamically apposed to the SMFs, for which reason we suggest to call them 'actin grips'. In conclusion, we describe a particular form of F-actin assembly with relevance for cytoskeletal organization in response to biomaterials, for endothelial-specific cell behavior in vitro and in vivo, and for tissue engineering. Copyright © 2015 Elsevier Ltd. All rights reserved.

  17. Public perceptions of a rip current hazard education program: “Break the Grip of the Rip!”

    Directory of Open Access Journals (Sweden)

    C. Houser

    2017-07-01

    Full Text Available Rip currents pose a major global beach hazard; estimates of annual rip-current-related deaths in the United States alone range from 35 to 100 per year. Despite increased social research into beach-goer experience, little is known about levels of rip current knowledge within the general population. This study describes the results of an online survey to determine the extent of rip current knowledge across the United States, with the aim of improving and enhancing existing beach safety education material. Results suggest that the US-based Break the Grip of the Rip!® campaign has been successful in educating the public about rip current safety directly or indirectly, with the majority of respondents able to provide an accurate description of how to escape a rip current. However, the success of the campaign is limited by discrepancies between personal observations at the beach and rip forecasts that are broadcasted for a large area and time. It was the infrequent beach user that identified the largest discrepancies between the forecast and their observations. Since infrequent beach users also do not seek out lifeguards or take the same precautions as frequent beach users, it is argued that they are also at greatest risk of being caught in a dangerous situation. Results of this study suggest a need for the national campaign to provide greater focus on locally specific and verified rip forecasts and signage in coordination with lifeguards, but not at the expense of the successful national awareness program.

  18. Drip, ship, and grip, then slice and dice: Comprehensive stroke center management of cervical and intracranial emboli.

    Directory of Open Access Journals (Sweden)

    Jason D Hinman

    2013-07-01

    Full Text Available BACKGROUND AND PURPOSE: Tandem acute thrombotic emboli in the cervical and intracranial arteries are an unusual case of stroke presenting unique management challenges. In regional systems of acute stroke care anchored by Comprehensive Stroke Centers, combined fibrinolytic, endovascular, and open surgical intervention is a new therapeutic option. SUMMARY OF CASE: A 28 year old male underwent retinal surgery, including post-operative neck compression and the next day presented to a primary stroke center with aphasia and right hemiplegia. Intravenous tissue plasminogen activator therapy was initiated and the patient was transferred to a comprehensive stroke center (CSC for higher level of care (drip and ship. Imaging at the CSC demonstrated tandem thrombi: a near occlusive lesion at the origin of the left cervical internal carotid artery and a total occlusion of the M1 segment of the left middle cerebral artery. Endovascular thrombectomy with the Solitaire stent retriever resulted in intracranial recanalization (grip. Immediately after the endovascular procedure, open carotid thrombectomy was performed to achieve cervical carotid revascularization without systemic heparinization (slice. Both cervical carotid and intracranial thrombi were processed for proteomic analysis via mass spectrometry (dice. CONCLUSION: Combined fibrinolytic, endovascular, and open surgical intervention can yield revascularization and good clinical outcome in cases of tandem lesions.

  19. Investigation of index finger triggering force using a cadaver experiment: Effects of trigger grip span, contact location, and internal tendon force.

    Science.gov (United States)

    Chang, Joonho; Freivalds, Andris; Sharkey, Neil A; Kong, Yong-Ku; Mike Kim, H; Sung, Kiseok; Kim, Dae-Min; Jung, Kihyo

    2017-11-01

    A cadaver study was conducted to investigate the effects of triggering conditions (trigger grip span, contact location, and internal tendon force) on index finger triggering force and the force efficiency of involved tendons. Eight right human cadaveric hands were employed, and a motion simulator was built to secure and control the specimens. Index finger triggering forces were investigated as a function of different internal tendon forces (flexor digitorum profundus + flexor digitorum superficialis = 40, 70, and 100 N), trigger grip spans (40, 50, and 60 mm), and contact locations between the index finger and a trigger. Triggering forces significantly increased when internal tendon forces increased from 40 to 100 N. Also, trigger grip spans and contact locations had significant effects on triggering forces; maximum triggering forces were found at a 50 mm span and the most proximal contact location. The results revealed that only 10-30% of internal tendon forces were converted to their external triggering forces. Copyright © 2017 Elsevier Ltd. All rights reserved.

  20. The association between physical activity and risk of mortality is modulated by grip strength and cardiorespiratory fitness: evidence from 498 135 UK-Biobank participants

    Science.gov (United States)

    Celis-Morales, Carlos A.; Lyall, Donald M.; Anderson, Jana; Iliodromiti, Stamatina; Fan, Yu; Ntuk, Uduakobong E.; Mackay, Daniel F.; Pell, Jill P.; Sattar, Naveed; Gill, Jason M.R.

    2017-01-01

    Aims It is unclear whether the potential benefits of physical activity differ according to level of cardiorespiratory fitness (CRF) or strength. The aim of this study was to determine whether the association between physical activity and mortality is moderated by CRF and grip strength sufficiently to inform health promotion strategies. Methods and results 498 135 participants (54.7% women) from the UK Biobank were included (CRF data available in 67 702 participants). Exposure variables were grip strength, CRF, and physical activity. All-cause mortality and cardiovascular disease (CVD) events were the outcomes. 8591 died over median 4.9 years [IQR 4.3–5.5] follow-up. There was a significant interaction between total physical activity and grip strength (P interaction with CRF did not reach statistical significance but the pattern was similar. The association between physical activity and mortality was larger among those in the lowest tertile of CRF (HR:1.13 [1.02–1.26]) than those in the highest (HR:1.03 [0.91–1.16]). The pattern for CVD events was similar. Conclusions These data provide novel evidence that strength, and possibly CRF, moderate the association between physical activity and mortality. The association between physical activity and mortality is strongest in those with the lowest strength (which is easily measured), and the lowest CRF, suggesting that these sub-groups could benefit most from interventions to increase physical activity. PMID:28158566

  1. Changes in pain, dysfunction, and grip strength of patients with acute lateral epicondylitis caused by frequency of physical therapy: a randomized controlled trial.

    Science.gov (United States)

    Lee, Soyoung; Ko, Youngjun; Lee, Wanhee

    2014-07-01

    [Purpose] The purpose of this study was to investigate the changes in pain, dysfunction, and grip strength of patients with acute lateral epicondylitis and to suggest the appropriate treatment frequency and period. [Subjects] The subjects were divided into three: 2 days per week group (n=12), 3 days per week group (n=15), and 6 days per week group (n=13). [Methods] All groups received conventional physical therapy for 40 minutes and therapeutic exercises for 20 minutes per session during 6 weeks. The outcome measurements were the visual analogue scale (VAS), Patient-Rated Tennis Elbow Evaluation (PRTEE), and grip strength. [Results] The results of this study were as follows: at 3 weeks, there were no significant differences in VAS and PRTEE in the 3 groups, but at 6 weeks, 6 days per week group significantly decreased these two outcomes. Grip strength was significantly increased in 3 and 6 days per week groups at 6 weeks. [Conclusion] In conclusion, physical therapy is needed 3 days per week for 3 weeks in patients with acute lateral epicondylitis. After 3 weeks, 6 days per week is the most effective treatment frequency.

  2. Improving communication on hope in palliative care. A qualitative study of palliative care professionals' metaphors of hope: grip, source, tune, and vision.

    Science.gov (United States)

    Olsman, Erik; Duggleby, Wendy; Nekolaichuk, Cheryl; Willems, Dick; Gagnon, Judith; Kruizinga, Renske; Leget, Carlo

    2014-11-01

    Hope is important in palliative care. However, palliative care professionals' perspectives on hope are not well understood. Metaphors of hope are a way of better understanding these perspectives. To describe palliative care professionals' perspectives on hope by examining the hope metaphors they spontaneously used to describe their own hope and their perspectives on the hope of patients and their families. Semistructured interviews with palliative care professionals were recorded, transcribed, and analyzed using a narrative approach. Results were discussed until the researchers reached consensus and reinforced by other health-care professionals and by observing several palliative care settings. The 64 participants (mean (SD) age, 48.42 (9.27) years and 72% female) were physicians (41%), nurses (34%), chaplains (20%), or other professionals (5%), working in Canada (19%) or The Netherlands (81%). Participants described the hope of patients, their families, or themselves as a 1) grip, which implied safety; 2) source, which implied strength; 3) tune, which implied harmony; and 4) vision, which implied a positive perspective. Compared with Dutch participants, Canadian participants generally put more emphasis on spirituality and letting go of their own hope as a grip (safety). Compared with other included professionals, physicians used hope as a grip (safety) most often, whereas chaplains used hope as a tune (harmony) most often. Our findings help to increase the understanding of hope and contribute to improving communication skills in palliative care professionals. Copyright © 2014 American Academy of Hospice and Palliative Medicine. Published by Elsevier Inc. All rights reserved.

  3. Association between dietary protein intake and grip strength among adults aged 51 years and over: What We Eat in America, National Health and Nutrition Examination Survey 2011-2014.

    Science.gov (United States)

    Mishra, Suruchi; Goldman, Joseph D; Sahyoun, Nadine R; Moshfegh, Alanna J

    2018-01-01

    Distributing daily protein intake evenly across meals (∼25-30g/meal) has been suggested to improve muscle mass. The aim of this research is to examine the association between grip strength, total protein intake and its distribution across day's meals in older adults. Nationally representative dietary intake data of adults aged 51 years and older (n = 4,123) who participated in What We Eat in America, NHANES 2011-2014 were analyzed. Protein intake per day and per eating occasion (breakfast, lunch, dinner, and snack) were determined. Combined grip strength was calculated and expressed in kilograms. Grip strength of individuals consuming ≥25g protein at 1 eating occasion was compared with those consuming same level of protein at 2 and 3 or more eating occasions. Grip strength of individuals in quartile 1 of daily protein intake was compared to those in the other quartiles. All associations were examined without and with adjustment for age, race/ethnicity, physical activity, health status, and smoking status. The comparison involving eating occasions and protein intake quartiles were further adjusted for daily protein intake and energy intake, respectively. Only 33% of men and 19% of women had protein intake of ≥25g at 2 or more eating occasions. These individuals also had higher grip strength and daily protein intake. Grip strength was positively associated with consumption of ≥25g protein at 2 eating occasions as compared to consumption of same level of protein at 1 eating occasion (peating occasions was not associated with grip strength. However, higher daily protein intake was positively associated with grip strength in women.

  4. The Effect of Dry Needling of the Trigger Points of Shoulder Muscles on Pain and Grip Strength in Patients with Lateral Epicondylitis: A Pilot Study

    Directory of Open Access Journals (Sweden)

    Alireza Kheradmandi

    2015-09-01

    Full Text Available Background: Lateral epicondylitis, also known as tennis elbow, is the most common overuse syndrome of the elbow. The severity of pain may not be directly caused by tendinopathy of wrist extensors since trigger points of the shoulder muscles have a referral zone in the arm and elbow. Therefore the aim of this study was to evaluate the effect of dry needling of shoulder myofascial trigger points on wrist extensors muscles pain and function. Methods: Fourteen female patients with tennis elbow (aged 20 - 45 years old were recruited after primary evaluation by an orthopedist. They entered the study if they had pain in the lateral aspect of elbow of the dominant hand for more than 3 months along with the presence of myofascial trigger points in any muscles of supra spinatus, infra spinatus, sub scapularis or scalenes. Pain pressure threshold, maximal grip force and pain intensity of the hand extensors on lateral epicondyle of elbow were measured before and after treatment. Pain intensity was measured on a one to ten scale of visual analogue scale (VAS. A hand dynamometer used to measure the maximal grip force value of the affected hand in 0˚shoulder flexion/ abduction, 90˚ elbow extension and mid-poison of forearm in sitting position. A pressure algometer was applied on hand extensor muscles to define their trigger point sensitivity. For the control group, treatment regimens consisted of routine physical therapy of tennis elbow. This regime was accompanied by dry needling of mentioned muscles for the intervention group. Wilcoxon and Mann-Whitney non-parametric tests were used for statistical analysis. Results: Comparison of the results after intervention showed that the patients’ pain significantly decreased in both groups (P<0.001; but the patient’s PPT and grip force significantly increased solely in the intervention group (P<0.05. Mann Whitney test showed significant pain differences in both groups (P=0.001. The comparison of differences

  5. Efeito da preensão manual sobre o equilíbrio de judocas Effect of hand grip on the balance of judokas

    Directory of Open Access Journals (Sweden)

    Jonathan Ache Dias

    2011-06-01

    Full Text Available O objetivo deste estudo foi verificar se existe efeito da preensão manual máxima (o ato de realizar ou não a preensão sobre o controle do equilíbrio de judocas em postura restrita, além de verificar se existe correlação entre a força de preensão manual (FPM e o controle do equilíbrio. Foram avaliados sete judocas com um dinamômetro e uma plataforma estabilométrica sendo mensuradas, concomitantemente, a FPM e o centro de pressão (CP. Foi verificado que até 80% da variabilidade do CP pode ser atrelada a preensão manual indicando que a mesma gera perturbações no controle do equilíbrio. Entretanto, foram encontradas correlações (r = 0,348 até 0,816 entre a FPM e o deslocamento do CP. Com isso pode-se concluir que, apesar da preensão manual gerar perturbações no equilíbrio, seu comportamento parece estar relacionado com os movimentos do corpo realizados para manter o equilíbrio, indicando uma possível correlação entre esses fenômenos.The purpose of this study was to verify if there is an effect of maximum hand grip (the act of performing or not the hand grip on the balance control of judokas in a restrict posture, and also to verify if there is a correlation between the hand grip strength (HGS and the balance control. Seven judokas were evaluated with a dynamometer and a stabilometric force platform, being measured, at the same time, the HGS and the center of pressure (COP. It was found that up to 80% of the COP variability was related to the hand grip demonstrating that it generates perturbations to the balance control. However, It was found correlations (r = 0,348 to 0,816 between de HGS and de COP displacement. With that, it can be concluded that, despite the hand grip generating perturbation on the balance, its behavior appears to be related to the body movements performed to sustain balance, indicating a possible correlation between this phenomenons.

  6. Comparison of hand grip strength and upper limb pressure pain threshold between older adults with or without non-specific shoulder pain

    Directory of Open Access Journals (Sweden)

    Cesar Calvo Lobo

    2017-02-01

    Full Text Available Background There is a high prevalence of non-specific shoulder pain associated with upper limb functional limitations in older adults. The purpose of this study was to determine the minimal clinically important differences (MCID of grip strength and pressure pain threshold (PPT in the upper limb between older adults with or without non-specific shoulder pain. Methods A case-control study was carried out following the Strengthening the Reporting of Observational Studies in Epidemiology (STROBE criteria. A sample of 132 shoulders (mean ± SD years with (n = 66; 76.04 ± 7.58 and without (n = 66; 75.05 ± 6.26 non-specific pain were recruited. The grip strength and PPT of the anterior deltoid and extensor carpi radialis brevis (ECRB muscles were assessed. Results There were statistically significant differences (mean ± SD; P-value for anterior deltoid PPT (2.51 ± 0.69 vs 3.68 ± 0.65, kg/cm2; P < .001, ECRB PPT (2.20 ± 0.60 vs 3.35 ± 0.38 kg/cm2; P < .001 and grip strength (20.78 ± 10.94 vs 24.63 ± 9.38 kg; P = .032 between shoulders with and without non-specific pain, respectively. Discussion The MCID of 1.17 kg/cm2, 1.15 kg/cm2 and 3.84 kg were proposed for anterior deltoid PPT, ECRB PPT and grip strength, respectively, to assess the upper limb of older adults with non-specific shoulder pain after treatment. In addition, univariate and multivariate (linear regression and regression trees analyses may be used to consider age distribution, sex, pain intensity, grip strength and PPT in older adults including clinical and epidemiological studies with non-specific shoulder pain.

  7. Hand-grip strength among older adults in Singapore: a comparison with international norms and associative factors.

    Science.gov (United States)

    Ong, Hui Lin; Abdin, Edimansyah; Chua, Boon Yiang; Zhang, Yunjue; Seow, Esmond; Vaingankar, Janhavi Ajit; Chong, Siow Ann; Subramaniam, Mythily

    2017-08-04

    Hand-grip strength (HGS) serves as a proxy measure for muscle function and physical health. Studies have shown that low HGS is associated with common age-related disorders including frailty and sarcopenia. The aim of the present study was to establish the normative values of HGS among older adults in Singapore and to compare it with data from Western and other Asian countries. The study also aimed to explore the sociodemographic and anthropometric correlates of HGS. Data were collected from 2043 men and women aged 60 years and above who took part in the Well-being of the Singapore Elderly study in 2013. HGS was obtained using a Jamar Plus + digital hand dynamometer. Normative data were stratified by; 5-year age groups, sex and ethnicity. Relationships between the HGS with various sociodemographic and anthropometric correlates were examined using multiple linear regression analysis. The mean HGS demonstrate a decreasing trend with increased age across all ethnic groups and sexes. HGS among Singapore older adults were relatively low compared to Western and other Asian countries. Males in the youngest age group (60-64) and of Chinese ethnicity attained greater HGS values than their counterparts. When the regression analysis was stratified for sex, significant associations were found between height, upper arm circumference with HGS in the males sample, and between height, weight, waist circumference and HGS in the females sample. Older adults in Singapore have a relatively weak HGS compared to other countries. Greater height and weight, and smaller waist circumference are independently associated with greater HGS in females but not males. These results facilitate the interpretation of HGS conducting using Jamar digital-type dynamometers among the older adults in Singapore.

  8. Serotonin and Histamine Therapy Increases Tetanic Forces of Myoblasts, Reduces Muscle Injury, and Improves Grip Strength Performance of Dmdmdx Mice

    Directory of Open Access Journals (Sweden)

    Volkan Gurel

    2015-11-01

    Full Text Available Duchenne muscular dystrophy (DMD is a recessive X-linked fatal disorder caused by a mutation in the dystrophin gene. Although several therapeutic approaches have been studied, none has led to substantial long-term effects in patients. The aim of this study was to test a serotonin and histamine (S&H combination on human skeletal myoblasts and Dmdmdx mice for its effects on muscle strength and injury. Normal human bioartificial muscles (BAMs were treated, and muscle tetanic forces and muscle injury tests were performed using the MyoForce Analysis System. Dmdmdx mice, the murine model of DMD, were administered serotonin, histamine, or S&H combination twice daily for 6 weeks, and functional performance tests were conducted once a week. The S&H combination treatment caused significant increases in tetanic forces at all time points and concentrations tested as compared to the saline controls. Dose response of the BAMs to the treatment demonstrated a significant increase in force generation at all concentrations compared to the controls after 3 to 4 days of drug treatment. The highest 3 concentrations had a significant effect on lowering contractile-induced injury as measured by a reduction in the release of adenylate kinase. Histamine-only and S&H treatments improved grip strength of Dmdmdx mice, whereas serotonin-only treatment resulted in no significant improvement in muscle strength. The results of this study indicate that S&H therapy might be a promising new strategy for muscular dystrophies and that the mechanism should be further investigated.

  9. Association between dietary protein intake and grip strength among adults aged 51 years and over: What We Eat in America, National Health and Nutrition Examination Survey 2011-2014.

    Directory of Open Access Journals (Sweden)

    Suruchi Mishra

    Full Text Available Distributing daily protein intake evenly across meals (∼25-30g/meal has been suggested to improve muscle mass. The aim of this research is to examine the association between grip strength, total protein intake and its distribution across day's meals in older adults.Nationally representative dietary intake data of adults aged 51 years and older (n = 4,123 who participated in What We Eat in America, NHANES 2011-2014 were analyzed. Protein intake per day and per eating occasion (breakfast, lunch, dinner, and snack were determined. Combined grip strength was calculated and expressed in kilograms. Grip strength of individuals consuming ≥25g protein at 1 eating occasion was compared with those consuming same level of protein at 2 and 3 or more eating occasions. Grip strength of individuals in quartile 1 of daily protein intake was compared to those in the other quartiles. All associations were examined without and with adjustment for age, race/ethnicity, physical activity, health status, and smoking status. The comparison involving eating occasions and protein intake quartiles were further adjusted for daily protein intake and energy intake, respectively.Only 33% of men and 19% of women had protein intake of ≥25g at 2 or more eating occasions. These individuals also had higher grip strength and daily protein intake. Grip strength was positively associated with consumption of ≥25g protein at 2 eating occasions as compared to consumption of same level of protein at 1 eating occasion (p<0.05 in unadjusted model, but not when adjusted. Grip strength was positively associated with daily protein intake among women in quartiles 3 and 4 (p<0.05 of protein intake in both unadjusted and adjusted models compared to lowest protein intake. Among men, grip strength was associated with daily protein intake in quartiles 3 and 4 (p<0.05 in the unadjusted model, but not when adjusted.In a nationally representative sample of older adults, consuming ≥25g

  10. Representing tools as hand movements: early and somatotopic visuomotor transformations.

    Science.gov (United States)

    Bartoli, Eleonora; Maffongelli, Laura; Jacono, Marco; D'Ausilio, Alessandro

    2014-08-01

    The term affordance defines a property of objects, which relates to the possible interactions that an agent can carry out on that object. In monkeys, canonical neurons encode both the visual and the motor properties of objects with high specificity. However, it is not clear if in humans exists a similarly fine-grained description of these visuomotor transformations. In particular, it has not yet been proven that the processing of visual features related to specific affordances induces both specific and early visuomotor transformations, given that complete specificity has been reported to emerge quite late (300-450ms). In this study, we applied an adaptation-stimulation paradigm to investigate early cortico-spinal facilitation and hand movements׳ synergies evoked by the observation of tools. We adapted, through passive observation of finger movements, neuronal populations coding either for precision or power grip actions. We then presented the picture of one tool affording one of the two grasps types and applied single-pulse Transcranial Magnetic Stimulation (TMS) to the hand primary motor cortex, 150ms after image onset. Cortico-spinal excitability of the Abductor Digiti Minimi and Abductor Pollicis Brevis showed a detailed pattern of modulations, matching tools׳ affordances. Similarly, TMS-induced hand movements showed a pattern of grip-specific whole hand synergies. These results offer a direct proof of the emergence of an early visuomotor transformation when tools are observed, that maintains the same amount of synergistic motor details as the actions we can perform on them. Copyright © 2014 The Authors. Published by Elsevier Ltd.. All rights reserved.

  11. Authoring Tools

    Science.gov (United States)

    Treviranus, Jutta

    Authoring tools that are accessible and that enable authors to produce accessible Web content play a critical role in web accessibility. Widespread use of authoring tools that comply to the W3C Authoring Tool Accessibility Guidelines (ATAG) would ensure that even authors who are neither knowledgeable about nor particularly motivated to produce accessible content do so by default. The principles and techniques of ATAG are discussed. Some examples of accessible authoring tools are described including authoring tool content management components such as TinyMCE. Considerations for creating an accessible collaborative environment are also covered. As part of providing accessible content, the debate between system-based personal optimization and one universally accessible site configuration is presented. The issues and potential solutions to address the accessibility crisis presented by the advent of rich internet applications are outlined. This challenge must be met to ensure that a large segment of the population is able to participate in the move toward the web as a two-way communication mechanism.

  12. Association between grip strength and diabetes prevalence in black, South-Asian, and white European ethnic groups: a cross-sectional analysis of 418 656 participants in the UK Biobank study.

    Science.gov (United States)

    Ntuk, U E; Celis-Morales, C A; Mackay, D F; Sattar, N; Pell, J P; Gill, J M R

    2017-08-01

    To quantify the extent to which ethnic differences in muscular strength might account for the substantially higher prevalence of diabetes in black and South-Asian compared with white European adults. This cross-sectional study used baseline data from the UK Biobank study on 418 656 white European, black and South-Asian participants, aged 40-69 years, who had complete data on diabetes status and hand-grip strength. Associations between hand-grip strength and diabetes were assessed using logistic regression and were adjusted for potential confounding factors. Lower grip strength was associated with higher prevalence of diabetes, independent of confounding factors, across all ethnicities in both men and women. Diabetes prevalence was approximately three- to fourfold higher in South-Asian and two- to threefold higher in black participants compared with white European participants across all levels of grip strength, but grip strength in South-Asian men and women was ~ 5-6 kg lower than in the other ethnic groups. Thus, the attributable risk for diabetes associated with low grip strength was substantially higher in South-Asian participants (3.9 and 4.2 cases per 100 men and women, respectively) than in white participants (2.0 and 0.6 cases per 100 men and women, respectively). Attributable risk associated with low grip strength was also high in black men (4.3 cases) but not in black women (0.4 cases). Low strength is associated with a disproportionately large number of diabetes cases in South-Asian men and women and in black men. Trials are needed to determine whether interventions to improve strength in these groups could help reduce ethnic inequalities in diabetes prevalence. © 2017 Diabetes UK.

  13. Tool steels

    DEFF Research Database (Denmark)

    Højerslev, C.

    2001-01-01

    On designing a tool steel, its composition and heat treatment parameters are chosen to provide a hardened and tempered martensitic matrix in which carbides are evenly distributed. In this condition the matrix has an optimum combination of hardness andtoughness, the primary carbides provide...... resistance against abrasive wear and secondary carbides (if any) increase the resistance against plastic deformation. Tool steels are alloyed with carbide forming elements (Typically: vanadium, tungsten, molybdenumand chromium) furthermore some steel types contains cobalt. Addition of alloying elements...... serves primarily two purpose (i) to improve the hardenabillity and (ii) to provide harder and thermally more stable carbides than cementite. Assuming proper heattreatment, the properties of a tool steel depends on the which alloying elements are added and their respective concentrations....

  14. Management Tools

    Science.gov (United States)

    1987-01-01

    Manugistics, Inc. (formerly AVYX, Inc.) has introduced a new programming language for IBM and IBM compatible computers called TREES-pls. It is a resource management tool originating from the space shuttle, that can be used in such applications as scheduling, resource allocation project control, information management, and artificial intelligence. Manugistics, Inc. was looking for a flexible tool that can be applied to many problems with minimal adaptation. Among the non-government markets are aerospace, other manufacturing, transportation, health care, food and beverage and professional services.

  15. Malaria's deadly grip

    DEFF Research Database (Denmark)

    Smith, Joseph D; Rowe, J Alexandra; Higgins, Matthew K

    2013-01-01

    Cytoadhesion of Plasmodium falciparum-infected erythrocytes to host microvasculature is a key virulence determinant. Parasite binding is mediated by a large family of clonally variant adhesion proteins, termed P. falciparum erythrocyte membrane protein 1 (PfEMP1), encoded by var genes and expressed...

  16. Associations of Walking Speed, Grip Strength, and Standing Balance With Total and Cause-Specific Mortality in a General Population of Japanese Elders.

    Science.gov (United States)

    Nofuji, Yu; Shinkai, Shoji; Taniguchi, Yu; Amano, Hidenori; Nishi, Mariko; Murayama, Hiroshi; Fujiwara, Yoshinori; Suzuki, Takao

    2016-02-01

    Walking speed, grip strength, and standing balance are key components of physical performance in older people. The present study aimed to evaluate (1) associations of these physical performance measures with cause-specific mortality, (2) independent associations of individual physical performance measures with mortality, and (3) the added value of combined use of the 3 physical performance measures in predicting all-cause and cause-specific mortality. Prospective cohort study with a follow-up of 10.5 years. Tokyo Metropolitan Institute of Gerontology Longitudinal Interdisciplinary Study on Aging (TMIG-LISA), Japan. A total of 1085 initially nondisabled older Japanese aged 65 to 89 years. Usual walking speed, grip strength, and standing balance were measured at baseline survey. During follow-up, 324 deaths occurred (122 of cardiovascular disease, 75 of cancer, 115 of other causes, and 12 of unknown causes). All 3 physical performance measures were significantly associated with all-cause, cardiovascular, and other-cause mortality, but not with cancer mortality, independent of potential confounders. When all 3 physical performance measures were simultaneously entered into the model, each was significantly independently associated with all-cause and cardiovascular mortality. The C statistics for all-cause and cardiovascular mortality were significantly increased by adding grip strength and standing balance to walking speed (P balance predicted all-cause, cardiovascular, and other-cause mortality, but not cancer mortality, independent of covariates. Moreover, these 3 components of physical performance were independently associated with all-cause and cardiovascular mortality and their combined use increased prognostic power. Copyright © 2016 AMDA – The Society for Post-Acute and Long-Term Care Medicine. Published by Elsevier Inc. All rights reserved.

  17. The Effect of Hand Dimensions, Hand Shape and Some Anthropometric Characteristics on Handgrip Strength in Male Grip Athletes and Non-Athletes

    Science.gov (United States)

    Fallahi, Ali Asghar; Jadidian, Ali Akbar

    2011-01-01

    It has been suggested that athletes with longer fingers and larger hand surfaces enjoy stronger grip power. Therefore, some researchers have examined a number of factors and anthropometric variables that explain this issue. To our knowledge, the data is scarce. Thus, the aim of this study was to investigate the effect of hand dimensions, hand shape and some anthropometric characteristics on handgrip strength in male grip athletes and non-athletes. 80 subjects aged between 19 and 29 participated in this study in two groups including: national and collegian grip athletes (n=40), and non-athletes (n=40). Body height and mass were measured to calculate body mass index. The shape of the dominant hand was drawn on a piece of paper with a thin marker so that finger spans, finger lengths, and perimeters of the hand could be measured. The hand shape was estimated as the ratio of the hand width to hand length. Handgrip strength was measured in the dominant and non-dominant hand using a standard dynamometer. Descriptive statistics were used for each variable and independent t test was used to analyze the differences between the two groups. The Pearson correlation coefficient test was used to evaluate the correlation between studied variables. Also, to predict important variables in handgrip strength, the linear trend was assessed using a linear regression analysis. There was a significant difference between the two groups in absolute handgrip strength (p0.05) were significantly different between the groups (ptalent identification in handgrip-related sports and in clinical settings as well. PMID:23486361

  18. The use of self-gripping (Progrip™) mesh during laparoscopic total extraperitoneal (TEP) inguinal hernia repair: a prospective feasibility and long-term outcomes study.

    Science.gov (United States)

    Bresnahan, Erin; Bates, Andrew; Wu, Andrew; Reiner, Mark; Jacob, Brian

    2015-09-01

    The use of self-gripping mesh during laparoscopic TEP inguinal hernia repairs may eliminate the need for any additional fixation, and thus reduce post-operative pain without the added concern for mesh migration. Long-term outcomes are not yet prospectively studied in a controlled fashion. Under IRB approval, from January 2011-April 2013, 91 hernias were repaired laparoscopically with self-gripping mesh without additional fixation. Patients were followed for at least 1 year. Demographics and intraoperative data (defect location, size, and mesh deployment time) are recorded. VAS is used in the recovery room (RR) to score pain, and the Carolinas Comfort Scale ™ (CCS), a validated 0-5 pain/quality of life (QoL) score where a mean score of >1.0 means symptomatic pain, is employed at 2 weeks and at 1 year. Morbidities, narcotic usage, days to full activity and return to work, and CCS scores are reported. Sixty two patients, with 91 hernias repaired with self-gripping mesh, completed follow-up at a mean time period of 14.8 months. Seventeen hernias were direct defects (average size 3.0 cm). Mesh deployment time was 193.7 s. RR pain was 1.1/10 using a VAS. Total average oxycodone/acetaminophen (5 mg/325 mg) usage = 5.0 tablets, days to full activity was 1.6, and return to work was 4.2 days. Thirteen small asymptomatic seromas were palpated without any recurrences or groin tenderness, and all seromas resolved by the 6 month visit. Transient testis discomfort was reported in five patients. Urinary retention was 3.2%. Mean CCS™ scores at the first visit for groin pain laying, bending, sitting, walking, and step-climbing were 0.2, 0.5, 0.4, 0.3, and 0.3, respectively. At the first post op visit, 4.8% had symptomatic pain (CCS > 1). At 14.8 months, no patients reported symptomatic pain with CCS scores for all 62 patients averaging 0.02, (range 0-0.43). There are no recurrences thus far. Self-gripping mesh can be safely used during laparoscopic TEP inguinal hernia repairs

  19. Effect of cervical vs. thoracic spinal manipulation on peripheral neural features and grip strength in subjects with chronic mechanical neck pain: a randomized controlled trial.

    Science.gov (United States)

    Bautista-Aguirre, Francisco; Oliva-Pascual-Vaca, Ángel; Heredia-Rizo, Alberto M; Boscá-Gandía, Juan J; Ricard, François; Rodriguez-Blanco, Cleofás

    2017-06-01

    Cervical and thoracic spinal manipulative therapy has shown positive impact for relief of pain and improve function in non-specific mechanical neck pain. Several attempts have been made to compare their effectiveness although previous studies lacked a control group, assessed acute neck pain or combined thrust and non-thrust techniques. To compare the immediate effects of cervical and thoracic spinal thrust manipulations on mechanosensitivity of upper limb nerve trunks and grip strength in patients with chronic non-specific mechanical neck pain. Randomized, single-blinded, controlled clinical trial. Private physiotherapy clinical consultancy. Eighty-eight subjects (32.09±6.05 years; 72.7% females) suffering neck pain (grades I or II) of at least 12 weeks of duration. Participants were distributed into three groups: 1) cervical group (N.=28); 2) thoracic group (N.=30); and 3) control group (N.=30). One treatment session consisting of applying a high-velocity low-amplitude spinal thrust technique over the lower cervical spine (C7) or the upper thoracic spine (T3) was performed, while the control group received a sham-manual contact. Measurements were taken at baseline and after intervention of the pressure pain threshold over the median, ulnar and radial nerves. Secondary measures included assessing free-pain grip strength with a hydraulic dynamometer. No statistically significant differences were observed when comparing between-groups in any of the outcome measures (P>0.05). Those who received thrust techniques, regardless of the manipulated area, reported an immediate increase in mechanosensitivity over the radial (both sides) and left ulnar nerve trunks (Ppain perception over the radial nerve also improved (P≤0.025). Low-cervical and upper-thoracic thrust manipulation is no more effective than placebo to induce immediate changes on mechanosensitivity of upper limb nerve trunks and grip strength in patients with chronic non-specific mechanical neck pain. A single

  20. Design tools

    Science.gov (United States)

    Anton TenWolde; Mark T. Bomberg

    2009-01-01

    Overall, despite the lack of exact input data, the use of design tools, including models, is much superior to the simple following of rules of thumbs, and a moisture analysis should be standard procedure for any building envelope design. Exceptions can only be made for buildings in the same climate, similar occupancy, and similar envelope construction. This chapter...

  1. Short-Term Effects of Whole-Body Vibration Combined with Task-Related Training on Upper Extremity Function, Spasticity, and Grip Strength in Subjects with Poststroke Hemiplegia: A Pilot Randomized Controlled Trial.

    Science.gov (United States)

    Lee, Jung-Sun; Kim, Chang-Yong; Kim, Hyeong-Dong

    2016-08-01

    The aim of this study was to determine the effect of whole-body vibration training combined with task-related training on arm function, spasticity, and grip strength in subjects with poststroke hemiplegia. Forty-five subjects with poststroke were randomly allocated to 3 groups, each with 15 subjects as follows: control group, whole-body vibration group, and whole-body vibration plus task-related training group. Outcome was evaluated by clinical evaluation and measurements of the grip strength before and 4 weeks after intervention. Our results show that there was a significantly greater increase in the Fugl-Meyer scale, maximal grip strength of the affected hand, and grip strength normalized to the less affected hand in subjects undergoing the whole-body vibration training compared with the control group after the test. Furthermore, there was a significantly greater increase in the Wolf motor function test and a decrease in the modified Ashworth spasticity total scores in subjects who underwent whole-body vibration plus task-related training compared with those in the other 2 groups after the test. The findings indicate that the use of whole-body vibration training combined with task-related training has more benefits on the improvement of arm function, spasticity, and maximal grip strength than conventional upper limb training alone or with whole-body vibration in people with poststroke hemiplegia.

  2. Coming to grips with challenging behaviour: a cluster randomised controlled trial on the effects of a new care programme for challenging behaviour on burnout, job satisfaction and job demands of care staff on dementia special care units.

    Science.gov (United States)

    Zwijsen, S A; Gerritsen, D L; Eefsting, J A; Smalbrugge, M; Hertogh, C M P M; Pot, A M

    2015-01-01

    Caring for people with dementia in dementia special care units is a demanding job. Challenging behaviour is one of the factors influencing the job satisfaction and burnout of care staff. A care programme for the challenging behaviour of nursing home residents with dementia might, next to diminishing the challenging behaviour of residents, improve job satisfaction and reduce the care staff's feelings of burnout. To determine the effects of a care programme for the challenging behaviour of nursing home residents with dementia on the burnout, job satisfaction and job demands of care staff. The care programme was implemented according to a stepped wedge design in which care units were randomly divided over five groups with different time points of starting with implementation. 17 Dutch dementia special care units. Care staff members of the 17 units. The care programme consists of an education package and of various structured assessment tools that guide professionals through the multidisciplinary detection, analysis, treatment and evaluation of treatment of challenging behaviour. Burnout, job satisfaction and job demands were measured before implementation, halfway through the implementation process and after all the care units had implemented the care programme. Burnout was measured with the Dutch version of the Maslach burnout inventory (UBOS-C, three subscales); job satisfaction and job demands were measured with subscales of the Leiden Quality of Work Questionnaire. Mixed model analyses were used to determine effects. Care staff could not be blinded for the intervention. Of the 1441 questionnaires, 645 were returned (response 45%, 318 control measurements, 327 intervention measurements) by 380 unique care staff members. Significant effects were found on job satisfaction (0.93, 95% CI 0.48-1.38). On the other outcomes, no significant changes in the scores were found. Positive effects of using the Grip on Challenging behaviour care programme were found on job

  3. A Strain-Based Method to Detect Tires’ Loss of Grip and Estimate Lateral Friction Coefficient from Experimental Data by Fuzzy Logic for Intelligent Tire Development

    Directory of Open Access Journals (Sweden)

    Jorge Yunta

    2018-02-01

    Full Text Available Tires are a key sub-system of vehicles that have a big responsibility for comfort, fuel consumption and traffic safety. However, current tires are just passive rubber elements which do not contribute actively to improve the driving experience or vehicle safety. The lack of information from the tire during driving gives cause for developing an intelligent tire. Therefore, the aim of the intelligent tire is to monitor tire working conditions in real-time, providing useful information to other systems and becoming an active system. In this paper, tire tread deformation is measured to provide a strong experimental base with different experiments and test results by means of a tire fitted with sensors. Tests under different working conditions such as vertical load or slip angle have been carried out with an indoor tire test rig. The experimental data analysis shows the strong relation that exists between lateral force and the maximum tensile and compressive strain peaks when the tire is not working at the limit of grip. In the last section, an estimation system from experimental data has been developed and implemented in Simulink to show the potential of strain sensors for developing intelligent tire systems, obtaining as major results a signal to detect tire’s loss of grip and estimations of the lateral friction coefficient.

  4. A Strain-Based Method to Detect Tires' Loss of Grip and Estimate Lateral Friction Coefficient from Experimental Data by Fuzzy Logic for Intelligent Tire Development.

    Science.gov (United States)

    Yunta, Jorge; Garcia-Pozuelo, Daniel; Diaz, Vicente; Olatunbosun, Oluremi

    2018-02-06

    Tires are a key sub-system of vehicles that have a big responsibility for comfort, fuel consumption and traffic safety. However, current tires are just passive rubber elements which do not contribute actively to improve the driving experience or vehicle safety. The lack of information from the tire during driving gives cause for developing an intelligent tire. Therefore, the aim of the intelligent tire is to monitor tire working conditions in real-time, providing useful information to other systems and becoming an active system. In this paper, tire tread deformation is measured to provide a strong experimental base with different experiments and test results by means of a tire fitted with sensors. Tests under different working conditions such as vertical load or slip angle have been carried out with an indoor tire test rig. The experimental data analysis shows the strong relation that exists between lateral force and the maximum tensile and compressive strain peaks when the tire is not working at the limit of grip. In the last section, an estimation system from experimental data has been developed and implemented in Simulink to show the potential of strain sensors for developing intelligent tire systems, obtaining as major results a signal to detect tire's loss of grip and estimations of the lateral friction coefficient.

  5. Muscle Fatigue in the Three Heads of the Triceps Brachii During a Controlled Forceful Hand Grip Task with Full Elbow Extension Using Surface Electromyography.

    Science.gov (United States)

    Ali, Asraf; Sundaraj, Kenneth; Badlishah Ahmad, R; Ahamed, Nizam Uddin; Islam, Anamul; Sundaraj, Sebastian

    2015-06-27

    The objective of the present study was to investigate the time to fatigue and compare the fatiguing condition among the three heads of the triceps brachii muscle using surface electromyography during an isometric contraction of a controlled forceful hand grip task with full elbow extension. Eighteen healthy subjects concurrently performed a single 90 s isometric contraction of a controlled forceful hand grip task and full elbow extension. Surface electromyographic signals from the lateral, long and medial heads of the triceps brachii muscle were recorded during the task for each subject. The changes in muscle activity among the three heads of triceps brachii were measured by the root mean square values for every 5 s period throughout the total contraction period. The root mean square values were then analysed to determine the fatiguing condition for the heads of triceps brachii muscle. Muscle fatigue in the long, lateral, and medial heads of the triceps brachii started at 40 s, 50 s, and 65 s during the prolonged contraction, respectively. The highest fatiguing rate was observed in the long head (slope = -2.863), followed by the medial head (slope = -2.412) and the lateral head (slope = -1.877) of the triceps brachii muscle. The results of the present study concurs with previous findings that the three heads of the triceps brachii muscle do not work as a single unit, and the fiber type/composition is different among the three heads.

  6. Grip strength measurements at two different wrist extension positions in chronic lateral epicondylitis-comparison of involved vs. uninvolved side in athletes and non athletes: a case-control study

    Directory of Open Access Journals (Sweden)

    Bhargava Arti S

    2010-09-01

    Full Text Available Abstract Background Lateral epicondylitis is a common sports injury of the elbow caused due to altered muscle activation during repetitive wrist extension in many athletic and non-athletic endeavours. The amount of muscle activity and timing of contraction eventually is directly dependent upon joint position during the activity. The purpose of our study was to compare the grip strength in athletes with lateral epicondylalgia in two different wrist extension positions and compare them between involved and uninvolved sides of athletes and non-athletes. Methods An assessor-blinded case-control study of eight athletes and twenty-two non-athletes was done. The grip strength was measured using JAMAR® hand dynamometer in kilograms-force at 15 degrees (slightly extended and 35 degrees (moderately extended wrist extension positions (maintained by wrist splints on both involved and uninvolved sides of athletes and non-athletes with unilateral lateral epicondylitis of atleast 3 months duration. Their pain was to be elicited with local tenderness and two of three tests being positive- Cozen's, Mill's manoeuvre, resisted middle finger extension tests. For comparisons of grip strength, Wilcoxon signed rank test was used for within-group comparison (between 15 and 35 degrees wrist extension positions and Mann-Whitney U test was used for between-group (athletes vs. non-athletes comparisons at 95% confidence interval and were done using SPSS 11.5 for Windows. Results Statistically significant greater grip strength was found in 15 degrees (27.75 ± 4.2 kgms in athletes; 16.45 ± 4.2 kgms in non-athletes wrist extension than at 35 degrees (25.25 ± 3.53 kgm in athletes and 14.18 ± 3.53 kgm in non-athletes. The athletes had greater grip strength than non-athletes in each of test positions (11.3 kgm at 15 degrees and 11.07 kgm at 35 degrees measured. There was also a significant difference between involved and uninvolved sides' grip strength at both wrist

  7. A novel gripper design for multi hand tools grasping under tight clearance constraints and external torque effect

    KAUST Repository

    Shaqura, Mohammad

    2017-08-29

    A robotic multi tool gripper design and implementation is presented in this paper. The proposed design targets applications where an actuation task is performed using a wide selection of standard hand tools. The manipulation motion is assumed to be rotational which requires a firm grip to account for external torque on the grasped tool. The setup is assumed to be a conventional workshop panel with hand tools being hanged close to each other, which constraints lateral clearance around the target, and near the wall of the panel, which constraints the depth clearance. Off the shelf grippers are mostly heavy and bulky which make them unsuitable for these requirements. Moreover, they are not optimized in terms of power consumption, simplicity and compactness. These generic grippers are mostly designed for pick and place tasks where no external torques other than those caused by the object weight affects the gripper. The design challenge involves building a gripper that is capable of operating in limited clearance space, firmly grip a variety of standard hand tools with different sizes and shapes. The proposed design is optimized for these objectives and offers a low cost and power consumption solution. The design has been validated in lab and outdoor experiments and has been deployed in real operating platform used in an international robotics competition.

  8. Hip muscle and hand-grip strength to differentiate between older fallers and non-fallers: a cross-sectional validity study

    Directory of Open Access Journals (Sweden)

    Gafner SC

    2017-12-01

    Full Text Available Simone C Gafner,1,2 Caroline H Bastiaenen,2,3 Serge Ferrari,4 Gabriel Gold,5 Philippe Terrier,6,7 Roger Hilfiker,8 Lara Allet1,91Department of Physiotherapy, HES-SO University of Applied Sciences and Arts of Western Switzerland, Geneva, Switzerland; 2Department of Epidemiology, Research Program Functioning and Rehabilitation, CAPHRI, Maastricht University, Maastricht, the Netherlands; 3Department of Health, School of Health Professions, Zurich University of Applied Sciences, Winterthur, 4Department of Internal Medicine Specialties, 5Department of Internal Medicine, Rehabilitation and Geriatrics, University Hospitals and University of Geneva, Geneva, 6Department of Research, Clinique romande de réadaptation SUVACare, 7Department of Research, Institute for Research in Rehabilitation, Sion, 8Department of Physiotherapy, School of Health Sciences, HES-SO Valais-Wallis, University of Applied Sciences and Arts of Western Switzerland, Valais, 9Department of Community Medicine, University Hospitals and University of Geneva, Geneva, Switzerland Background: Hip muscle weakness in older people seems to be an influencing factor of falls. Currently, it is unclear which muscles out of the hip muscle group play an important role in older people. A validating process in the measurement regarding muscle strength related to falls is necessary before answering that question.Objective: Firstly, we aimed to investigate which hip muscle group strength shows an acceptable level of distinction between older adult fallers and non-fallers compared to a predefined external criterion regarding falling. Secondly, we aimed to compare the same outcomes and questions for hand-grip strength in relation to the same external criterion.Design: This study was a cross-sectional validity study.Methods: The maximum voluntary isometric strength (MVIS and the rate of force generation of hip abductors (ABD, adductors, internal and external rotators, extensors, and flexors were measured

  9. Effect of low appendicular lean mass, grip strength, and gait speed on the functional outcome after surgery for distal radius fractures.

    Science.gov (United States)

    Roh, Young Hak; Noh, Jung Ho; Gong, Hyun Sik; Baek, Goo Hyun

    2017-12-01

    Patients with low appendicular lean mass plus slow gait speed or weak grip strength are at risk for poor functional recovery after surgery for distal radius fracture, even when they have similar radiologic outcomes. Loss of skeletal muscle mass and consequent loss in muscle function associate with aging, and this condition negatively impacts the activities of daily living and increases elderly individuals' frailty to falls. Thus, patients with low appendicular lean mass would show different functional recovery compared to those without this condition after surgery for distal radius fracture (DRF). This study compares the functional outcomes after surgery for DRF in patients with or without low appendicular lean mass plus slowness or weakness. A total of 157 patients older than 50 years of age with a DRF treated via volar plate fixation were enrolled in this prospective study. A definition of low appendicular lean mass with slowness or weakness was based on the consensus of the Asian Working Group for Sarcopenia. The researchers compared functional assessments (wrist range of motion and Michigan Hand Questionnaire [MHQ]) and radiographic assessments (radial inclination, volar tilt, ulnar variance, and articular congruity) 12 months after surgery between patients with and without low appendicular lean mass plus slowness or weakness. Multivariable regression analyses were performed to determine whether appendicular lean mass, grip strength, gait speed, patient demographic, or injury characteristics accounted for the functional outcomes. Patients with low appendicular lean mass plus slowness or weakness showed a significantly lower recovery of MHQ score than those in the control group throughout 12 months. There was no significant difference in the range of motion between the groups. The radiologic outcomes showed no significant difference between groups in terms of volar tilt, radial inclination, or ulnar variance. According to multivariable regression analysis

  10. Sustained effect of resistance training on blood pressure and hand grip strength following a detraining period in elderly hypertensive women: a pilot study

    Directory of Open Access Journals (Sweden)

    Nascimento D da C

    2014-01-01

    Full Text Available Dahan da Cunha Nascimento,1,5,8 Ramires Alsamir Tibana,1,8 Franklin M Benik,2 Keila Elizabeth Fontana,3 Frederico Ribeiro Neto,8 Frederico Santos de Santana,5,8 Leopoldo Santos-Neto,4 Renato André Sousa Silva,1,5,6 Alessandro Oliveira Silva,1,7 Darlan Lopes Farias,1,7 Sandor Balsamo,4,5,8 Jonato Prestes1 1Postgraduate Program in Physical Education, Catholic University of Brasilia, Brasilia, Brazil; 2Department of Kinesiology and Sports Studies Graduate Program, Eastern Illinois University, Charleston, IL, USA; 3Faculty of Physical Education, University of Brasilia, Brasilia, Brazil; 4Graduate Program in Medical Sciences of the University of Brasilia, School of Medicine and Rheumatology Service, University Hospital of Brasilia (HUB, Brasilia, Brazil; 5Department of Physical Education, University Center Euro American University Center, Brasilia, Brazil; 6Center of Excellence in Medicine of Exercise (CEMEx, Brasilia, Brazil; 7Center University of Brasilia (UNICEUB, Brasilia, Brazil; 8Strength Training and Health Research Group (GEPEEFS, Brasilia, Brazil Introduction: Hypertension is the most prevalent modifiable risk factor with a high prevalence among older adults. Exercise is a nonpharmacological treatment shown to benefit all patients with hypertension. Objective: This study examined the effects of a 14-week moderate intensity resistance training program (RT on the maintenance of blood pressure and hand grip strength during an extended detraining period in elderly hypertensive women. Methods: Twelve hypertensive sedentary elderly women completed 14 weeks of whole body RT at a moderate perceived exertion following a detraining period of 14 weeks. Results: Following the training period, participants demonstrated an increase in absolute hand grip strength (P=0.001, relative hand grip strength (P=0.032 and a decrease of systolic (P=0.001, diastolic (P=0.008, and mean blood pressure (P=0.002 when compared to pre-exercise values. In addition, these

  11. Confined Tube Crimp Using Portable Hand Tools

    Energy Technology Data Exchange (ETDEWEB)

    Reynolds, Joseph James [Los Alamos National Laboratory; Pereyra, R. A. [LANL Retired; Archuleta, Jeffrey Christopher [Los Alamos National Laboratory; Martinez, Isaac P. [Los Alamos National Laboratory; Nelson, A. M. [MST-16 Summer Student (2007); Allen, Ronald Scott [Los Alamos National Laboratory; Page, R. L. [LANL Retired; Freer, Jerry Eugene [Los Alamos National Laboratory; Dozhier, Nathan Gus [Los Alamos National Laboratory

    2016-04-04

    The Lawrence Radiation Laboratory developed handheld tools that crimp a 1/16 inch OD tube, forming a leak tight seal1 (see Figure 1). The leak tight seal forms by confining the 1/16 inch OD tubing inside a die while applying crimp pressure. Under confined pressure, the tube walls weld at the crimp. The purpose of this study was to determine conditions for fabricating a leak tight tube weld. The equipment was used on a trial-and-error basis, changing the conditions after each attempt until successful welds were fabricated. To better confine the tube, the die faces were polished. Polishing removed a few thousandths of an inch from the die face, resulting in a tighter grip on the tubing wall. Using detergent in an ultrasonic bath, the tubing was cleaned. Also, the time under crimp pressure was increased to 30 seconds. With these modifications, acceptable cold welds were fabricated. After setting the conditions for an acceptable cold weld, the tube was TIG welded across the crimped face.

  12. Estimation of precipitation rates by measurements of {sup 36}Cl in the GRIP ice core with the PSI/ETH tandem accelerator

    Energy Technology Data Exchange (ETDEWEB)

    Wagner, G.; Baumgartner, S.; Beer, J. [EAWAG, Duebendorf (Switzerland); Synal, H.A. [Paul Scherrer Inst. (PSI), Villigen (Switzerland); Suter, M. [Eidgenoessische Technische Hochschule, Zurich (Switzerland)

    1997-09-01

    Within the European Greenland ice core project (GRIP) {sup 36}Cl AMS measurements have been performed on ice core samples from Summit (Greenland, 73{sup o}N, 37{sup o}W). Most data analysed so far are from the lower part of the ice core. The {sup 36}Cl concentration is well correlated with {delta}{sup 18}O, which is considered as a proxy for paleotemperatures. Assuming that the deposition rate of radionuclides is independent of {delta}{sup 18}O, {sup 36}Cl is used to estimate the relationship between accumulation and {delta}{sup 18}O. The results confirm that the rapid changes of {delta}{sup 18}O, the so-called Dansgaard-Oeschger events, are also reflected in the precipitation rate. (author) 1 fig., 3 refs.

  13. Long-term outcome of muscle strength in ulnar and median nerve injury: Comparing manual muscle strength testing, grip and pinch strength dynamometers and a new intrinsic muscle strength dynamometer

    NARCIS (Netherlands)

    A.R. Schreuders (Ton); M.E. Roebroeck (Marij); J.B. Jaquet (Jean); S.E.R. Hovius (Steven); H.J. Stam (Henk)

    2004-01-01

    textabstractObjective: To compare the outcome of muscle strength with manual muscle strength testing grip and pinch strength measurements and a dynamometer which allows for measurements of the intrinsic muscles of the hand in isolation (the Rotterdam Intrinsic Hand Myometer, RIHM). Methods:

  14. Determination the validity of the new developed Sport Experts® hand grip dynamometer, measuring continuity of force, and comparison with current Takei and Baseline® dynamometers.

    Science.gov (United States)

    Güçlüöver, A; Kutlu, M; Ciğerci, A E; Esen, H T; Demirkan, E; Erdoğdu, M

    2015-11-01

    In this study the Sport Experts ™ brand of hand grip dynamometer, measuring the continuity of force with the new developed load cell technology, was compared with Takei and Baseline® dynamometers, the current in use. It was tried to determine the correlation between them. In a study with provides use of clinical, orthopedic and rehabilitative purposes in the athletes and patient populations, this developed dynamometer can provide useful data by observing the continuity of force. The sample of the study included 60 badminton players in 2010-2011; consisting of Turkish Junior National male players (N.=16, age: 16.8±1.5), Junior National female players (N.=14, age: 16.9±1.6), amateur level male players (N.=15, age: 16.3±0.8) and amateur level female players (N.=15, age: 16.1±0.6). ANOVA was used in the statistical methods in order to compare the hand grip strength made by different brands; Pearson's correlation coefficient was used to determine the relationship level between dynamometers. Furthermore, test-retest reliability analysis was completed the new developed expert dynamometer. There was no statistically significant difference in the comparison of the dynamometers (P>0.05). Besides, a highly significant relationship (r=0.95 to 0.96) was found among all three dynamometers. However, the reliability coefficient was found (Chronbachs α: 0.989, ICC:0.97, r=0.97), (Pexpert dynamometer. Comparison between the dynamometers and the statistical results obtained from the correlation relationships shows interchangeability of dynamometers. As a result, our observation of force continuity (progression) of the athlete and patient populations is thought to be important.

  15. Clinical Outcomes of Living Liver Transplantation According to the Presence of Sarcopenia as Defined by Skeletal Muscle Mass, Hand Grip, and Gait Speed.

    Science.gov (United States)

    Harimoto, N; Yoshizumi, T; Izumi, T; Motomura, T; Harada, N; Itoh, S; Ikegami, T; Uchiyama, H; Soejima, Y; Nishie, A; Kamishima, T; Kusaba, R; Shirabe, K; Maehara, Y

    2017-11-01

    Sarcopenia is an independent predictor of death after living-donor liver transplantation (LDLT). However, the ability of the Asian Working Group for Sarcopenia criteria for sarcopenia (defined as reduced skeletal muscle mass plus low muscle strength) to predict surgical outcomes in patients who have undergone LDLT has not been determined. This study prospectively enrolled 366 patients who underwent LDLT at Kyushu University Hospital. Skeletal muscle area (determined by computed tomography), hand-grip strength, and gait speed were measured in 102 patients before LDLT. We investigated the relationship between sarcopenia and surgical outcomes after LDLT performed in three time periods. The number of patients with lower skeletal muscle area has increased to 52.9% in recent years. The incidence of sarcopenia according to the Asian Working Group for Sarcopenia criteria was 23.5% (24/102). Patients with sarcopenia (defined by skeletal muscle area and functional parameters) had significantly lower skeletal muscle area and weaker hand-grip strength than did those without sarcopenia. Compared with non-sarcopenic patients, patients with sarcopenia also had significantly worse liver function, greater estimated blood loss, greater incidence of postoperative complications of Clavien-Dindo grade IV or greater (including amount of ascites on postoperative day 14, total bilirubin on postoperative day 14, and postoperative sepsis), and longer postoperative hospital stay. Multiple logistic regression analysis revealed sarcopenia as a significant predictor of 6-month mortality. The combination of skeletal muscle mass and function can predict surgical outcomes in LDLT patients. Copyright © 2017 Elsevier Inc. All rights reserved.

  16. Hurricane Imaging Radiometer (HIRAD) Observations of Brightness Temperatures and Ocean Surface Wind Speed and Rain Rate During NASA's GRIP and HS3 Campaigns

    Science.gov (United States)

    Miller, Timothy L.; James, M. W.; Roberts, J. B.; Jones, W. L.; Biswas, S.; Ruf, C. S.; Uhlhorn, E. W.; Atlas, R.; Black, P.; Albers, C.

    2012-01-01

    HIRAD flew on high-altitude aircraft over Earl and Karl during NASA s GRIP (Genesis and Rapid Intensification Processes) campaign in August - September of 2010, and plans to fly over Atlantic tropical cyclones in September of 2012 as part of the Hurricane and Severe Storm Sentinel (HS3) mission. HIRAD is a new C-band radiometer using a synthetic thinned array radiometer (STAR) technology to obtain spatial resolution of approximately 2 km, out to roughly 30 km each side of nadir. By obtaining measurements of emissions at 4, 5, 6, and 6.6 GHz, observations of ocean surface wind speed and rain rate can be retrieved. The physical retrieval technique has been used for many years by precursor instruments, including the Stepped Frequency Microwave Radiometer (SFMR), which has been flying on the NOAA and USAF hurricane reconnaissance aircraft for several years to obtain observations within a single footprint at nadir angle. Results from the flights during the GRIP and HS3 campaigns will be shown, including images of brightness temperatures, wind speed, and rain rate. Comparisons will be made with observations from other instruments on the campaigns, for which HIRAD observations are either directly comparable or are complementary. Features such as storm eye and eye-wall, location of storm wind and rain maxima, and indications of dynamical features such as the merging of a weaker outer wind/rain maximum with the main vortex may be seen in the data. Potential impacts on operational ocean surface wind analyses and on numerical weather forecasts will also be discussed.

  17. Factors influencing power hand tool fastening accuracy and reaction forces.

    Science.gov (United States)

    Radwin, Robert G; Chourasia, Amrish O; Howery, Robert S; Fronczak, Frank J; Yen, Thomas Y; Subedi, Yashpal; Sesto, Mary E

    2014-06-01

    A laboratory study investigated the relationship between power hand tool and task-related factors affecting threaded fastener torque accuracy and associated handle reaction force. We previously developed a biodynamic model to predict handle reaction forces. We hypothesized that torque accuracy was related to the same factors that affect operator capacity to react against impulsive tool forces, as predicted by the model. The independent variables included tool (pistol grip on a vertical surface, right angle on a horizontal surface), fastener torque rate (hard, soft), horizontal distance (30 cm and 60 cm), and vertical distance (80 cm, 110 cm, and 140 cm). Ten participants (five male and five female) fastened 12 similar bolts for each experimental condition. Average torque error (audited - target torque) was affected by fastener torque rate and operator position. Torque error decreased 33% for soft torque rates, whereas handle forces greatly increased (170%). Torque error also decreased for the far horizontal distance 7% to 14%, when vertical distance was in the middle or high, but handle force decreased slightly 3% to 5%. The evidence suggests that although both tool and task factors affect fastening accuracy, they each influence handle reaction forces differently. We conclude that these differences are attributed to different parameters each factor influences affecting the dynamics of threaded faster tool operation. Fastener torque rate affects the tool dynamics, whereas posture affects the spring-mass-damping biodynamic properties of the human operator. The prediction of handle reaction force using an operator biodynamic model may be useful for codifying complex and unobvious relationships between tool and task factors for minimizing torque error while controlling handle force.

  18. Tool path in torus tool CNC machining

    Directory of Open Access Journals (Sweden)

    XU Ying

    2016-10-01

    Full Text Available This paper is about tool path in torus tool CNC machining.The mathematical model of torus tool is established.The tool path planning algorithm is determined through calculation of the cutter location,boundary discretization,calculation of adjacent tool path and so on,according to the conversion formula,the cutter contact point will be converted to the cutter location point and then these points fit a toolpath.Lastly,the path planning algorithm is implemented by using Matlab programming.The cutter location points for torus tool are calculated by Matlab,and then fit these points to a toolpath.While using UG software,another tool path of free surface is simulated of the same data.It is drew compared the two tool paths that using torus tool is more efficient.

  19. Remote tooling applications at the FFTF/IEM cell

    International Nuclear Information System (INIS)

    Webb, R.H.

    1990-01-01

    At the fast flux test facility, a US Government-owned 400-MW(thermal) sodium-cooled fast reactor, the interim examination and maintenance (IEM) cell is used for the remote disassembly of irradiated fuel and material experiments and remote maintenance operations. The IEM cell has been a challenging area both for maintenance and operation of remote equipment. Innovative tooling has been required to provide the reliability, strength and dexterity for performing myriad bolting, cutting, gripping, and other such functions. Over the years, a set of basic components that can be modified and adapted to several applications has been developed. These include torque multipliers, torque limiters, right-angle drives, and many common hand tools with fittings designed to be handled by master-slave manipulators (MSM) or electromechanical manipulator (EMM) hands. An example of such a system is the closed loop ex-vessel machine (CLEM) grapple change tool, which is designed for both hands-on use in a glove box and remote use in the IEM cell

  20. A dinamometria manual e seu uso na avaliação nutricional Hand grip strength test and its use in nutritional assessment

    Directory of Open Access Journals (Sweden)

    Michael Maia Schlüssel

    2008-04-01

    Full Text Available Esta revisão de literatura aborda aspectos metodológicos e fisiológicos da dinamometria manual. A dinamometria manual é um teste funcional do músculo esquelético que vem recebendo uma crescente atenção de clínicos e pesquisadores da área de saúde nos últimos anos. Recentemente, tem merecido atenção como indicador do estado nutricional, particularmente para pacientes internados. Dentre os principais fatores que influenciam esta medida, destacam-se o sexo, a idade, a estatura, a massa corporal e a mão dominante dos indivíduos. Os resultados desta revisão demonstram ainda que diversos outros fatores, relacionados ao protocolo de aferição, como a posição do indivíduo, o tipo de instrumento utilizado, o número de aferições realizadas, o intervalo de descanso entre as aferições, a presença de estímulo verbal e de um pré-teste, também podem influenciar os valores alcançados por um indivíduo em uma avaliação da dinamometria manual. Dessa forma, é importante que um protocolo de aferição padronizado seja desenvolvido, para que se obtenham medidas válidas de dinamometria manual. Ainda são escassos os estudos que propõem valores de referência para a dinamometria manual e a literatura ainda se ressente de valores de referência baseados em dados obtidos a partir de amostras de base populacional.This paper reviews the methodological and physiological aspects of hand grip strength measurement. Hand grip strength assesses skeletal muscle function and has received increasing attention from physicians and health-related researchers in the last years. Recently, it has deserved particular attention as an indicator of nutritional status, particularly in hospitalized patients. Sex, age, height, body mass and the dominant hand of the subjects are the main factors that influence the measure. The results of this review demonstrate that many other factors associated with the assessment protocol, such as the position of the

  1. Plug testing and removal tool

    International Nuclear Information System (INIS)

    Baric, T.J.; Kauric, C.E.; Garcia, C.N.

    1987-01-01

    This patent describes an apparatus for testing and removing a plug from an aperture in the cylindrical core barrel wall of a nuclear reactor. The plug has an enlarged head disposed along the wall in a narrow annular access space between the wall and a surrounding cylindrical thermal neutron shield. The apparatus comprises: fixed jaw means; movable jaw means pivotally connected to the fixed jaw means for movement with respect thereto between an open position accommodating reception of the plug head between the fixed and movable jaw means and a closed position for securely gripping the plug head between the fixed and movable jaw means; drive means carried by the fixed jaw means and coupled to the movable jaw means for effecting movement thereof between the open and closed positions thereof; and tensioning means carried by the jaw means for engagement with the core barrel when the jaw means are disposed in gripping engagement with the plug head for exerting on the jaw means and the gripped plug a predetermined force in a direction radially outwardly of the wall. The jaw means and the drive means and the tensioning means all have dimensions radially of the wall substantially less than the radial thickness of the access space to permit insertion into, movement within and removal from the access space

  2. Useful design tools?

    DEFF Research Database (Denmark)

    Jensen, Jesper Ole

    2005-01-01

    vague and contested concept of sustainability into concrete concepts and building projects. It describes a typology of tools: process tools, impact assessment tools, multi-criteria tools and tools for monitoring. It includes a Danish paradigmatic case study of stakeholder participation in the planning...... of a new sustainable settlement. The use of design tools is discussed in relation to innovation and stakeholder participation, and it is stressed that the usefulness of design tools is context dependent....

  3. CoC GIS Tools (GIS Tool)

    Data.gov (United States)

    Department of Housing and Urban Development — This tool provides a no-cost downloadable software tool that allows users to interact with professional quality GIS maps. Users access pre-compiled projects through...

  4. Feasibility of an Assessment Tool for Children's Competence to Consent to Predictive Genetic Testing: a Pilot Study

    NARCIS (Netherlands)

    Hein, Irma M.; Troost, Pieter W.; Lindeboom, Robert; Christiaans, Imke; Grisso, Thomas; van Goudoever, Johannes B.; Lindauer, Ramón J. L.

    2015-01-01

    Knowledge on children's capacities to consent to medical treatment is limited. Also, age limits for asking children's consent vary considerably between countries. Decision-making on predictive genetic testing (PGT) is especially complicated, considering the ongoing ethical debate. In order to

  5. EEG-informed fMRI analysis during a hand grip task: estimating the relationship between EEG rhythms and the BOLD signal

    Directory of Open Access Journals (Sweden)

    Roberta eSclocco

    2014-04-01

    Full Text Available In the last decade, an increasing interest has arisen in investigating the relationship between the electrophysiological and hemodynamic measurements of brain activity, such as EEG and (BOLD fMRI. In particular, changes in BOLD have been shown to be associated with changes in the spectral profile of neural activity, rather than with absolute power. Concurrently, recent findings showed that different EEG rhythms are independently related to changes in the BOLD signal: therefore, it would be important to distinguish between the contributions of the different EEG rhythms to BOLD fluctuations when modeling the relationship between the two signals. Here we propose a method to perform EEG-informed fMRI analysis, in which the EEG regressors take into account both the changes in the spectral profile and the rhythms distinction. We applied it to EEG-fMRI data during a hand grip task in healthy subjects, and compared the results with those obtained by two existing models found in literature. Our results showed that the proposed method better captures the correlations between BOLD signal and EEG rhythms modulations, identifying task-related, well localized activated volumes. Furthermore, we showed that including among the regressors also EEG rhythms not primarily involved in the task enhances the performance of the analysis, even when only correlations with BOLD signal and specific EEG rhythms are explored.

  6. Hook-up of GluA2, GRIP and liprin-α for cholinergic muscarinic receptor-dependent LTD in the hippocampus

    Directory of Open Access Journals (Sweden)

    Wu Long-Jun

    2009-06-01

    Full Text Available Abstract The molecular mechanism underlying muscarinic acetylcholine receptor-dependent LTD (mAChR-LTD in the hippocampus is less studied. In a recent study, a novel mechanism is described. The induction of mAChR-LTD required the activation of protein tyrosine phosphatase (PTP, and the expression was mediated by AMPA receptor endocytosis via interactions between GluA2, GRIP and liprin-α. The hook-up of these proteins may result in the recruitment of leukocyte common antigen-related receptor (LAR, a PTP that is known to be involved in AMPA receptor trafficking. Interestingly, the similar molecular interaction cannot be applied to mGluR-LTD, despite the fact that the same G-protein involved in LTD is activated by both mAChR and mGluR. This discovery provides key molecular insights for cholinergic dependent cognitive function, and mAChR-LTD can serve as a useful cellular model for studying the roles of cholinergic mechanism in learning and memory.

  7. The Reliability and Validity of Toe Grip Strength as an Index of Physical Development in 4- to 5-Year-Old Children

    Institute of Scientific and Technical Information of China (English)

    Takahiro Ikeda[1; Osamu Aoyagi[2

    2015-01-01

    Studies on TGS (toe-grip strength) are currently proliferating as a result of the development of the dynamometer. The purpose of the present study was to investigate the reliability and validity of TGS as a physical function in preschool aged children. The participants were 153 preschoolers. Each participant was measured in terms of his or her TGS and completed a MAT (motor ability test). The reliability of the measurements was investigated via Pearson's r and Cronbach's a through a test-retest method, as well as a Bland-Altman plot. The validity of the TGS value was investigated by measuring the correlation between TGS and each component of the MAT, the principal component analysis, and a two-way layout ANOVA with general linear model (gender and age). All reliability coefficients were more than 0.70. Though all components of the MAT relating to TGS were found to be significant (P 〈 0.05), these correlations were weak. However, TGS was found to be a physical function that relating to the lower limbs and develops with aging. Therefore, TGS was found to be a highly reliable measure of physical function performance in preschoolers.

  8. Imaginary Pasts: Colonisation, Migration and Loss in J.G. Farrell’s 'The Singapore Grip' and in Amitav Ghosh’s 'The Glass Palace'

    Directory of Open Access Journals (Sweden)

    Michael C. Prusse

    2009-11-01

    Full Text Available A quotation from each of the two novels that form the background for this paper will immediately establish why these narratives are pertinent to the central theme of the ‘Moving Cultures, Shifting Identities Conference’ that took place at Flinders University in Adelaide early in December 2007. In both texts the theme of migration in the context of imperialism plays a central role and, moreover, both clearly spell out what tremendous impact moving between and across cultures has on the lives of people, who are thoroughly affected and marked by such encounters. Matthew Webb, one of the protagonists of J.G. Farrell’s The Singapore Grip (1978, renders his perception of the phenomenon of migration in the wake of imperial expansion as follows: ‘One of the most astounding things about our Empire … is the way we’ve transported vast populations across the globe as cheap labour’. Matthew, a critical observer of British imperialism but still a member of colonial society and a British citizen, thus provides the reader with an insight regarding the economic motivation behind such enforced movements of people.

  9. The influence of respiratory acid-base changes on muscle performance and excitability of the sarcolemma during strenuous intermittent hand grip exercise.

    Science.gov (United States)

    Hilbert, M; Shushakov, V; Maassen, N

    2012-02-01

    Acidification has been reported to provide protective effects on force production in vitro. Thus, in this study, we tested if respiratory acid-base changes influence muscle function and excitability in vivo. Nine subjects performed strenuous, intermittent hand grip exercises (10 cycles of 15 s of work/45 s of rest) under respiratory acidosis by CO(2) rebreathing, alkalosis by hyperventilation, or control. The Pco(2), pH, K(+) concentration ([K(+)]), and Na(+) concentration were measured in venous and arterialized blood. Compound action potentials (M-wave) were elicited to examine the excitability of the sarcolemma. The surface electromyogram (EMG) was recorded to estimate the central drive to the muscle. The lowest venous pH during the exercise period was 7.24 ± 0.03 in controls, 7.31 ± 0.05 with alkalosis, and 7.17 ± 0.04 with acidosis (P alkalosis, and, after the second cycle, it was smaller with acidosis than with the control condition (P Respiratory alkalosis stabilized the M-wave area without influencing performance. Thus, we did not find a direct link between performance and alteration of excitability of the sarcolemma due to changes in pH in vivo.

  10. Ücretsiz mevsimsel grip aşılarını yaptıran kişilerin, ücretsiz pandemik grip aşısı karşısındaki tutum ve davranışları

    Directory of Open Access Journals (Sweden)

    Muzaffer Eskiocak

    2011-09-01

    Full Text Available Amaç: Bu çalışma, mevsimsel grip aşısına (MGA ücretsiz erişen insanların tutum ve davranışlarını, yine ücretsiz, ama çeşitli tartışmalara konu olan pandemik grip aşısı (PGA karşısındaki tutum ve davranışlarıyla karşılaştırmak amacıyla yapılmıştır. Yöntem: Araştırma tanımlayıcı tipte bir araştırmadır ve Kırklareli-Evrensekiz Sağlık Ocağı bölgesinde, Şubat,2009–Şubat,2010 tarihleri arasında yürütülmüştür. Çalışma anketi yüz-yüze görüşme yöntemiyle doldurulmuştur. Bulgular: Katılımcıların %99,2’si (n=125 kamu kurumlarının ücretsiz MGA sağlamasını destekliyordu ve tamamı (N=126 gelecek yıl da ücretsiz MGA temin edilmesini istiyordu. 2010 yılında yapılan ikinci ankette ücretsiz sağlanan PGA olanların oranının ise %4 (n=5 olduğu tespit edildi. Sonuç: Bağışıklama hizmetlerinden yararlanmada ekonomik faktörlerin çok önemli olduğu, ancak toplumun güven duygusunun zedelenmesinin, ücretsiz sağlansa da aşılamayı ciddi düzeyde engellediği saptanmıştır.Anahtar Kelimeler: Mevsimsel grip aşısı, pandemik grip aşısı Attitudes and behaviors related to free pandemic influenza vaccination of who gets vaccinated with free seasonal influenza vaccine  Objective: This study aims to compare attitudes and behaviors of the people who receive free Seasonal Influenza Vaccine (SIV with their attitudes and behaviors against Pandemic Influenza Vaccine (PIV which is also free, but controversial. Method: This study is a descriptive survey which was carried out within the service area of Evrensekiz Primary Healthcare Center (PHC in Kırklareli province and it was conducted between February 2009 and February 2010. The questionnaire has been applied by face to face interviews. Results: 99,2%of participants (n=125 supported providing free influenza vaccine by governmental organizations and all of them (N=126 wanted to get free influenza vaccine the next year

  11. The power tool

    International Nuclear Information System (INIS)

    HAYFIELD, J.P.

    1999-01-01

    POWER Tool--Planning, Optimization, Waste Estimating and Resourcing tool, a hand-held field estimating unit and relational database software tool for optimizing disassembly and final waste form of contaminated systems and equipment

  12. The Takei Handheld Dynamometer: An Effective Clinical Outcome Measure Tool for Hand and Wrist Function in Boxing.

    Science.gov (United States)

    Gatt, Ian; Smith-Moore, Sophie; Steggles, Charlie; Loosemore, Mike

    2018-05-01

    The aim of this article was to explore retrospectively the Takei dynamometer as a valid and reliable outcome measure tool for hand and wrist pathology in the Great Britain amateur boxing squad between 2010 and 2014. Longitudinal retrospective injury surveillance of the Great Britain boxing squad was performed from 2010 to 2014. The location, region affected, description, and duration of each injury were recorded by the team doctor and team physiotherapists. For each significant injury, we recorded hand grip scores using the Takei handheld dynamometer and compared the scores with baseline measures. At the hand, fractures and dislocations were highly detected with an average difference of 40.2% ( P 20% should be highly considered for significant pathology. The Takei dynamometer is a valid and reliable outcome measure tool for hand and wrist pathologies in boxing. Our study highlights the importance of appropriate clinical tools to guide injury management in this sport.

  13. Synchronising EDML and NorthGRIP ice cores using d18O of atmospheric oxygen (d18 Oatm) and CH4 measurements over MIS5 (80-123 kyr)

    DEFF Research Database (Denmark)

    Capron, E; Landais, A; Lemieux-Dudon, B

    2010-01-01

    Water isotope records from the EPICA Dronning Maud Land (EDML) and the NorthGRIP ice cores have revealed a one to one coupling between Antarctic Isotope Maxima (AIM) and Greenland Dansgaard-Oeschger (DO) events back to 50 kyr. In order to explore if this north-south coupling is persistent over...... Marine Isotopic Stage 5 (MIS 5). a common timescale must first be constructed. Here, we present new records of delta O-18 of O-2 (delta O-18(atm)) and methane (CH4) measured in the air trapped in ice from the EDML (68-147 kyr) and NorthGRIP (70-123 kyr) ice cores. We demonstrate that, through the period...... of interest, CH4 records alone are not sufficient to construct a common gas timescale between the two cores. Millennial-scale variations of delta O-18(atm) are evidenced over MIS 5 both on the Antarctic and Greenland ice cores and are coupled to CH4 profiles to synchronise the NorthGRIP and EDML records...

  14. The neutron porosity tool

    International Nuclear Information System (INIS)

    Oelgaard, P.L.

    1988-01-01

    The report contains a review of available information on neutron porosity tools with the emphasis on dual thermal-neutron-detector porosity tools and epithermal-neutron-detector porosity tools. The general principle of such tools is discussed and theoretical models are very briefly reviewed. Available data on tool designs are summarized with special regard to the source-detector distance. Tool operational data, porosity determination and correction of measurements are briefly discussed. (author) 15 refs

  15. Preset pivotal tool holder

    Science.gov (United States)

    Asmanes, Charles

    1979-01-01

    A tool fixture is provided for precise pre-alignment of a radiused edge cutting tool in a tool holder relative to a fixed reference pivot point established on said holder about which the tool holder may be selectively pivoted relative to the fixture base member to change the contact point of the tool cutting edge with a workpiece while maintaining the precise same tool cutting radius relative to the reference pivot point.

  16. Dutch Risk Assessment tools

    NARCIS (Netherlands)

    Venema, A.

    2015-01-01

    The ‘Risico- Inventarisatie- en Evaluatie-instrumenten’ is the name for the Dutch risk assessment (RA) tools. A RA tool can be used to perform a risk assessment including an evaluation of the identified risks. These tools were among the first online risk assessment tools developed in Europe. The

  17. New QC 7 tools

    International Nuclear Information System (INIS)

    1982-03-01

    This book tells of new QC with 7 tools which includes TQC and new QC with 7 tools which is for better propel, what is QC method to think? what is new QC 7 tool ? like KJ law, PDPC law, arrow and diagram law, and matrix diagram law, application of new QC 7 tools such as field to apply, application of new QC 7 tools for policy management the method of new QC 7 tools including related regulations KJ law, matrix and data analysis, PDPC law and education and introduction of new QC 7 tools.

  18. Grip strength, postural control, and functional leg power in a representative cohort of British men and women: associations with physical activity, health status, and socioeconomic conditions.

    Science.gov (United States)

    Kuh, Diana; Bassey, E Joan; Butterworth, Suzanne; Hardy, Rebecca; Wadsworth, Michael E J

    2005-02-01

    Understanding the health, behavioral, and social factors that influence physical performance in midlife may provide clues to the origins of frailty in old age and the future health of elderly populations. The authors evaluated muscle strength, postural control, and chair rise performance in a large representative prospective cohort of 53-year-old British men and women in relation to functional limitations, body size, health and activity, and socioeconomic conditions. Nurses interviewed 2984 men and women in their own homes in England, Scotland, and Wales and conducted physical examinations in 2956 of them. Objective measures were height, weight, and three physical performance tests: handgrip strength, one-legged standing balance time, and time to complete 10 chair rises. Functional limitations (difficulties walking, stair climbing, gripping, and falls), health status, physical activity, and social class were obtained using a structured questionnaire. Those with the worst scores on the physical performance tests had higher rates of functional limitations for both upper and lower limbs. Women had much weaker handgrip strength, somewhat poorer balance time, and only slightly poorer chair rise time compared with men. In women, health problems and low levels of physical activity contributed to poor physical performance on all three measures. In men, physical activity was the predominant influence. Heavier weight and poorer socioeconomic conditions contributed to poorer balance and chair rise times. In this representative middle-aged group, physical performance levels varied widely, and women were seriously disadvantaged compared with men. In general, physical performance was worse for men and women living in poorer socioeconomic conditions with greater body weight, poorer health status, and inactive lifestyles. These findings support recommendations for controlling excess body weight, effective health interventions, and the maintenance of active lifestyles during aging.

  19. Does a history of physical exposures at work affect hand-grip strength in midlife? A retrospective cohort study in Denmark.

    Science.gov (United States)

    Møller, Anne; Reventlow, Susanne; Hansen, Åse Marie; Andersen, Lars L; Siersma, Volkert; Lund, Rikke; Avlund, Kirsten; Andersen, Johan Hviid; Mortensen, Ole S

    2013-11-01

    The aim of this cohort study was to examine associations between physical exposures throughout working life and hand-grip strength (HGS) in midlife. The Copenhagen Aging and Midlife Biobank (CAMB) provided data about employment and HGS for 3843 Danes. Individual job histories, including duration of employment in specific jobs, were assigned exposures from a job exposure matrix. Exposures were standardized to ton-years (lifting 1000 kg each day in one year), stand-years (standing/walking for six hours each day in one year) and kneel-years (kneeling for one hour each day in one year). The effects of exposure-years on HGS were analyzed as linear effects and cubic splines in multivariate regression models, adjusted for potential confounders. Mean age was 59 years among both genders and HGS was 49.19 kg [standard deviation (SD) 8.42] and 30.61 kg (SD 5.49) among men and women, respectively. Among men, exposure to kneel-years was associated with higher HGS [>0.030 kg (P=0.007) per exposure-year]. Ton- and stand-years were not associated with HGS among either men or women in linear analyses. In spline regression analyses, associations between ton- and stand-years and HGS were non-linear and primarily positive among men. Among women, the associations were non-linear and, according to ton-years, primarily negatively associated with HGS but statistically insignificant. A history of physical exposures at work explained only a minor part of the variation in HGS, though exposure to kneeling throughout working life was associated with a slightly higher HGS among men. Exposure to lifting and standing/walking was not associated with HGS.

  20. Comparative investigations of manual action representations: evidence that chimpanzees represent the costs of potential future actions involving tools.

    Science.gov (United States)

    Frey, Scott H; Povinelli, Daniel J

    2012-01-12

    The ability to adjust one's ongoing actions in the anticipation of forthcoming task demands is considered as strong evidence for the existence of internal action representations. Studies of action selection in tool use reveal that the behaviours that we choose in the present moment differ depending on what we intend to do next. Further, they point to a specialized role for mechanisms within the human cerebellum and dominant left cerebral hemisphere in representing the likely sensory costs of intended future actions. Recently, the question of whether similar mechanisms exist in other primates has received growing, but still limited, attention. Here, we present data that bear on this issue from a species that is a natural user of tools, our nearest living relative, the chimpanzee. In experiment 1, a subset of chimpanzees showed a non-significant tendency for their grip preferences to be affected by anticipation of the demands associated with bringing a tool's baited end to their mouths. In experiment 2, chimpanzees' initial grip preferences were consistently affected by anticipation of the forthcoming movements in a task that involves using a tool to extract a food reward. The partial discrepancy between the results of these two studies is attributed to the ability to accurately represent differences between the motor costs associated with executing the two response alternatives available within each task. These findings suggest that chimpanzees are capable of accurately representing the costs of intended future actions, and using those predictions to select movements in the present even in the context of externally directed tool use.

  1. Nanocomposites for Machining Tools

    Directory of Open Access Journals (Sweden)

    Daria Sidorenko

    2017-10-01

    Full Text Available Machining tools are used in many areas of production. To a considerable extent, the performance characteristics of the tools determine the quality and cost of obtained products. The main materials used for producing machining tools are steel, cemented carbides, ceramics and superhard materials. A promising way to improve the performance characteristics of these materials is to design new nanocomposites based on them. The application of micromechanical modeling during the elaboration of composite materials for machining tools can reduce the financial and time costs for development of new tools, with enhanced performance. This article reviews the main groups of nanocomposites for machining tools and their performance.

  2. Tool grinding machine

    Science.gov (United States)

    Dial, Sr., Charles E.

    1980-01-01

    The present invention relates to an improved tool grinding mechanism for grinding single point diamond cutting tools to precise roundness and radius specifications. The present invention utilizes a tool holder which is longitudinally displaced with respect to the remainder of the grinding system due to contact of the tool with the grinding surface with this displacement being monitored so that any variation in the grinding of the cutting surface such as caused by crystal orientation or tool thickness may be compensated for during the grinding operation to assure the attainment of the desired cutting tool face specifications.

  3. Improved tool grinding machine

    Science.gov (United States)

    Dial, C.E. Sr.

    The present invention relates to an improved tool grinding mechanism for grinding single point diamond cutting tools to precise roundness and radius specifications. The present invention utilizes a tool holder which is longitudinally displaced with respect to the remainder of the grinding system due to contact of the tool with the grinding surface with this displacement being monitored so that any variation in the grinding of the cutting surface such as caused by crystal orientation or tool thicknesses may be compensated for during the grinding operation to assure the attainment of the desired cutting tool face specifications.

  4. Tools for Manipulation and Characterisation of Nanostructures

    DEFF Research Database (Denmark)

    Mølhave, Kristian; Bøggild, Peter

    grippers, which were then successfully used for pick-and-place manipulation of silicon nanowires. For increased gripping force and control over the manipulation process, microfabricated grippers with integrated force-feedback were also demonstrated. Environmental electron beam deposition (EEBD...... components that are some 10000 times smaller....

  5. Tools of online Marketing

    OpenAIRE

    Hossain, M. S.; Rahman, M. F.

    2017-01-01

    Abstract Online marketing is the most crucial issue in the modern marketing era but there was no previous research that could identify the tools of internet marketing before this study and it was the first study on the field of online marketing tools. This research was descriptive in nature and it has attempted to identify the major tools of internet marketing from the concepts of traditional marketing tools. Worldwide network is known as Internet that can exchange information between use...

  6. OOTW COST TOOLS

    Energy Technology Data Exchange (ETDEWEB)

    HARTLEY, D.S.III; PACKARD, S.L.

    1998-09-01

    This document reports the results of a study of cost tools to support the analysis of Operations Other Than War (OOTW). It recommends the continued development of the Department of Defense (DoD) Contingency Operational Support Tool (COST) as the basic cost analysis tool for 00TWS. It also recommends modifications to be included in future versions of COST and the development of an 00TW mission planning tool to supply valid input for costing.

  7. Get a grip on physics

    CERN Document Server

    Gribbin, John

    2011-01-01

    What do Newton's falling apple and the moon's orbit have in common? How does relativity theory apply to everyday life, what's a quantum leap, and why is Schrödinger's cat inside that box? The answers lie within your grasp! John Gribbin, a physicist and author of bestselling popular-science books, offers down-to-earth discussions of technical topics. Playful engravings and cartoons illustrate his imaginative accounts of the workings of string theory, black holes, superfluidity, and other cosmic oddities. Readers of all ages will appreciate these memorable explanations of the laws of physics and

  8. At closer grips with ITP

    International Nuclear Information System (INIS)

    Heyns, A.du P.; Pieters, H.; Wessels, P.; Loetter, M.G.; Badenhorst, P.N.; Kotze, H.F.

    1986-01-01

    An excessive destruction of platelets characterises Immune Thrombocytopenic Purpura (ITP) - a relatively common blood disease, particularly in the young. With the use of In-111 as platelet label there was focused on the mean platelet life span, the efficacy of increased platelet production by the bone marrow in the face of increased platelet destruction, the role of the spleen in ITP, and the different patterns of platelet sequestration in this disease

  9. Getting to grips with antihydrogen

    CERN Multimedia

    Katarina Anthony

    2012-01-01

    In June 2011, the ALPHA Collaboration announced that they had successfully managed to trap and hold atoms of antimatter for 1000 seconds. Last week they announced that their success in changing the internal state of antihydrogen and made the first ever measurement of its spectrum. The Collaboration is now installing an all-new experimental set-up – ALPHA-2 – and shows no signs of slowing down its investigations into the anti-world.   The ALPHA experiment hall. Newspapers and magazines around the world described the recent ALPHA announcement as the first step towards explaining why antimatter and matter did not cancel each other out in the first instances of creation, that is, why our universe of matter exists. Understanding the behaviour of matter and antimatter can help scientists solve this conundrum. With this in mind, the ALPHA collaboration has begun the study of the antihydrogen spectrum. So far, the Collaboration has been focused on proving that they can alter the ...

  10. Pro Tools HD

    CERN Document Server

    Camou, Edouard

    2013-01-01

    An easy-to-follow guide for using Pro Tools HD 11 effectively.This book is ideal for anyone who already uses ProTools and wants to learn more, or is new to Pro Tools HD and wants to use it effectively in their own audio workstations.

  11. Nanocomposites for Machining Tools

    DEFF Research Database (Denmark)

    Sidorenko, Daria; Loginov, Pavel; Mishnaevsky, Leon

    2017-01-01

    Machining tools are used in many areas of production. To a considerable extent, the performance characteristics of the tools determine the quality and cost of obtained products. The main materials used for producing machining tools are steel, cemented carbides, ceramics and superhard materials...

  12. Motor Unit Number Estimate and Isometric Hand Grip Strength in Military Veterans with or Without Muscular Complaints: Reference Values for Longitudinal Follow-up.

    Science.gov (United States)

    Li, Mian; Yao, Wenguo; Sundahl, Cynthia

    2018-03-26

    It remains unclear if Gulf War (GW) veterans have a higher risk of developing motor neuron disorder. We intended to establish baseline neurophysiological values, including thenar motor unit number estimate (MUNE) and isometric hand grip (IHG) strength, to compare future follow-ups of deployed GW veterans with or without muscular complaints. We evaluated 19 GW veterans with self-reported weakness, cramps, or excessive muscle fatigue (Ill-19) and compared them with 18 controls without such muscular complaints (C-18). We performed MUNE on hand thenar muscles using adapted multipoint stimulation method for Ill-19 and 15 controls (C-15). We measured IHG strength (maximum force, endurance, and fatigue level) on Ill-19 and C-18 with a hand dynamometer. We performed nerve conduction studies on all study participants to determine which subjects had mild carpal tunnel syndrome (CTS). We compared the MUNE and IHG strength measures between Ill group and controls and between those with CTS and those without CTS. We obtained thenar MUNE of Ill-19 (95% CI of mean: 143-215; mean age: 46 yr) and compared it with that of C-15 (95% CI of mean: 161-230; mean age: 45 yr), and 95% of CI of mean among IHG strength variables (maximum force: 324-381 Newton; endurance: 32-42 s; fatigue level: 24%-33%) compared with C-18 (maximum force: 349-408 Newton; endurance: 35-46 s; fatigue level: 21%-27%). There was no significant difference in either MUNE or IHG strength between Ill-19 group and controls. The MUNE and IHG maximum forces were significantly lower in those with CTS compared with those without CTS. As a surrogate of mild CTS, the median versus ulnar distal sensory latency on nerve conduction study was only weakly associated with MUNE, maximum force, and fatigue level, respectively. To our knowledge, no published study on MUNE reference values of military veteran population has been available. The quantifiable values of both thenar MUNE and IHG strength of military veterans serve as

  13. Pickering tool management system

    International Nuclear Information System (INIS)

    Wong, E.H.; Green, A.H.

    1997-01-01

    Tools were being deployed in the station with no process in effect to ensure that they are maintained in good repair so as to effectively support the performance of Maintenance activities. Today's legal requirements require that all employers have a process in place to ensure that tools are maintained in a safe condition. This is specified in the Ontario Health and Safety Act. The Pickering Tool Management System has been chosen as the process at Pickering N.D to manage tools. Tools are identified by number etching and bar codes. The system is a Windows application installed on several file servers

  14. Machine tool structures

    CERN Document Server

    Koenigsberger, F

    1970-01-01

    Machine Tool Structures, Volume 1 deals with fundamental theories and calculation methods for machine tool structures. Experimental investigations into stiffness are discussed, along with the application of the results to the design of machine tool structures. Topics covered range from static and dynamic stiffness to chatter in metal cutting, stability in machine tools, and deformations of machine tool structures. This volume is divided into three sections and opens with a discussion on stiffness specifications and the effect of stiffness on the behavior of the machine under forced vibration c

  15. New tools help libraries to harvest literature in CERN library

    CERN Document Server

    Geretschläger, Ingrid

    2002-01-01

    Electronic publishing makes material accessible to more people, but this is not always a problem-free process. Ingrid Geretschlager and Jocelyne Jerdelet describe how the CERN library got to grips with a bewildering array of formats and approaches.

  16. P2-37: Processing Affordance Information from Invisible Tool Images

    Directory of Open Access Journals (Sweden)

    Shinho Cho

    2012-10-01

    Full Text Available A recent study showed that viewing manipulable objects such as images of tools induces the neural activation of posterior parietal areas. This neural activation is observed even when visual awareness of the image is visually suppressed. (Fang and He, 2005 Nature Neuroscience 10 1380–1385; Almeida et al, 2010 Psychological Science 21 772–778. However, the specific visuomotor information in tool images that drives the activation of dorsal areas is still unclear. We measured priming effect of invisible tool prime (left or right handed orientation. Observers distinguished the orientation of target tools (appropriate for left vs right handed grip briefly presented following visually suppressed primes (Experiment1. Also we measured the suppression time of tool images whose handle direction was presented in a left- or right-handed orientation. A dynamic noise pattern was presented to one of the observer's eyes at full contrast, while images of tools (left or right handed were simultaneously presented to the left or right visual field of the other eye. The subjects were asked to respond to the appearance of any partial or full part of the test image (Experiment 2. Results showed that (1 observers responded faster in the congruent condition (the same orientation between prime and target and (2 tool images shown in the right visual field took less time to gain dominance against the dynamic noise. These results suggest that even without overt recognition of presented tools, an object's affordance can be registered and processed in the brain. A recent study showed that viewing manipulable objects such as images of tools induces the neural activation of posterior parietal areas. This neural activation is observed even when visual awareness of the image is visually suppressed (Almeida et al., 2010 Psychological Science 21 772–778; Fang and He, 2005 Nature Neuroscience 10 1380–1385. However, the specific visuomotor information in tool images that

  17. Open Health Tools: Tooling for Interoperable Healthcare

    Directory of Open Access Journals (Sweden)

    Skip McGaughey

    2008-11-01

    Full Text Available The Open Health Tools initiative is creating an ecosystem focused on the production of software tooling that promotes the exchange of medical information across political, geographic, cultural, product, and technology lines. At its core, OHT believes that the availability of high-quality tooling that interoperates will propel the industry forward, enabling organizations and vendors to build products and systems that effectively work together. This will ?raise the interoperability bar? as a result of having tools that just work. To achieve these lofty goals, careful consideration must be made to the constituencies that will be most affected by an OHT-influenced world. This document outlines a vision of OHT?s impact to these stakeholders. It does not explain the OHT process itself or how the OHT community operates. Instead, we place emphasis on the impact of that process within the health industry. The catchphrase ?code is king? underpins this document, meaning that the manifestation of any open source community lies in the products and technology it produces.

  18. Scheme Program Documentation Tools

    DEFF Research Database (Denmark)

    Nørmark, Kurt

    2004-01-01

    are separate and intended for different documentation purposes they are related to each other in several ways. Both tools are based on XML languages for tool setup and for documentation authoring. In addition, both tools rely on the LAML framework which---in a systematic way---makes an XML language available...... as named functions in Scheme. Finally, the Scheme Elucidator is able to integrate SchemeDoc resources as part of an internal documentation resource....

  19. Agreement Workflow Tool (AWT)

    Data.gov (United States)

    Social Security Administration — The Agreement Workflow Tool (AWT) is a role-based Intranet application used for processing SSA's Reimbursable Agreements according to SSA's standards. AWT provides...

  20. Instant Spring Tool Suite

    CERN Document Server

    Chiang, Geoff

    2013-01-01

    Filled with practical, step-by-step instructions and clear explanations for the most important and useful tasks. A tutorial guide that walks you through how to use the features of Spring Tool Suite using well defined sections for the different parts of Spring.Instant Spring Tool Suite is for novice to intermediate Java developers looking to get a head-start in enterprise application development using Spring Tool Suite and the Spring framework. If you are looking for a guide for effective application development using Spring Tool Suite, then this book is for you.

  1. Chimera Grid Tools

    Science.gov (United States)

    Chan, William M.; Rogers, Stuart E.; Nash, Steven M.; Buning, Pieter G.; Meakin, Robert

    2005-01-01

    Chimera Grid Tools (CGT) is a software package for performing computational fluid dynamics (CFD) analysis utilizing the Chimera-overset-grid method. For modeling flows with viscosity about geometrically complex bodies in relative motion, the Chimera-overset-grid method is among the most computationally cost-effective methods for obtaining accurate aerodynamic results. CGT contains a large collection of tools for generating overset grids, preparing inputs for computer programs that solve equations of flow on the grids, and post-processing of flow-solution data. The tools in CGT include grid editing tools, surface-grid-generation tools, volume-grid-generation tools, utility scripts, configuration scripts, and tools for post-processing (including generation of animated images of flows and calculating forces and moments exerted on affected bodies). One of the tools, denoted OVERGRID, is a graphical user interface (GUI) that serves to visualize the grids and flow solutions and provides central access to many other tools. The GUI facilitates the generation of grids for a new flow-field configuration. Scripts that follow the grid generation process can then be constructed to mostly automate grid generation for similar configurations. CGT is designed for use in conjunction with a computer-aided-design program that provides the geometry description of the bodies, and a flow-solver program.

  2. Easy QC 7 tools

    International Nuclear Information System (INIS)

    1981-04-01

    This book explains method of QC 7 tools, mind for using QC 7 tools, effect of QC 7 tools application, giving descriptions of graph, pareto's diagram like application writing way and using method of pareto's diagram, characteristic diagram, check sheet such as purpose and subject of check, goals and types of check sheet, and using point of check sheet, histogram like application and using method, and stratification, scatterplot, control chart, promotion method and improvement and cases of practice of QC tools.

  3. Java Power Tools

    CERN Document Server

    Smart, John

    2008-01-01

    All true craftsmen need the best tools to do their finest work, and programmers are no different. Java Power Tools delivers 30 open source tools designed to improve the development practices of Java developers in any size team or organization. Each chapter includes a series of short articles about one particular tool -- whether it's for build systems, version control, or other aspects of the development process -- giving you the equivalent of 30 short reference books in one package. No matter which development method your team chooses, whether it's Agile, RUP, XP, SCRUM, or one of many other

  4. Easy QC 7 tools

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1981-04-15

    This book explains method of QC 7 tools, mind for using QC 7 tools, effect of QC 7 tools application, giving descriptions of graph, pareto's diagram like application writing way and using method of pareto's diagram, characteristic diagram, check sheet such as purpose and subject of check, goals and types of check sheet, and using point of check sheet, histogram like application and using method, and stratification, scatterplot, control chart, promotion method and improvement and cases of practice of QC tools.

  5. Qlikview Audit Tool (QLIKVIEW) -

    Data.gov (United States)

    Department of Transportation — This tool supports the cyclical financial audit process. Qlikview supports large volumes of financial transaction data that can be mined, summarized and presented to...

  6. Thermomechanical conditions and stresses on the friction stir welding tool

    Science.gov (United States)

    Atthipalli, Gowtam

    Friction stir welding has been commercially used as a joining process for aluminum and other soft materials. However, the use of this process in joining of hard alloys is still developing primarily because of the lack of cost effective, long lasting tools. Here I have developed numerical models to understand the thermo mechanical conditions experienced by the FSW tool and to improve its reusability. A heat transfer and visco-plastic flow model is used to calculate the torque, and traverse force on the tool during FSW. The computed values of torque and traverse force are validated using the experimental results for FSW of AA7075, AA2524, AA6061 and Ti-6Al-4V alloys. The computed torque components are used to determine the optimum tool shoulder diameter based on the maximum use of torque and maximum grip of the tool on the plasticized workpiece material. The estimation of the optimum tool shoulder diameter for FSW of AA6061 and AA7075 was verified with experimental results. The computed values of traverse force and torque are used to calculate the maximum shear stress on the tool pin to determine the load bearing ability of the tool pin. The load bearing ability calculations are used to explain the failure of H13 steel tool during welding of AA7075 and commercially pure tungsten during welding of L80 steel. Artificial neural network (ANN) models are developed to predict the important FSW output parameters as function of selected input parameters. These ANN consider tool shoulder radius, pin radius, pin length, welding velocity, tool rotational speed and axial pressure as input parameters. The total torque, sliding torque, sticking torque, peak temperature, traverse force, maximum shear stress and bending stress are considered as the output for ANN models. These output parameters are selected since they define the thermomechanical conditions around the tool during FSW. The developed ANN models are used to understand the effect of various input parameters on the total

  7. EPR design tools. Integrated data processing tools

    International Nuclear Information System (INIS)

    Kern, R.

    1997-01-01

    In all technical areas, planning and design have been supported by electronic data processing for many years. New data processing tools had to be developed for the European Pressurized Water Reactor (EPR). The work to be performed was split between KWU and Framatome and laid down in the Basic Design contract. The entire plant was reduced to a logical data structure; the circuit diagrams and flowsheets of the systems were drafted, the central data pool was established, the outlines of building structures were defined, the layout of plant components was planned, and the electrical systems were documented. Also building construction engineering was supported by data processing. The tasks laid down in the Basic Design were completed as so-called milestones. Additional data processing tools also based on the central data pool are required for the phases following after the Basic Design phase, i.e Basic Design Optimization; Detailed Design; Management; Construction, and Commissioning. (orig.) [de

  8. Data Tools and Apps

    Science.gov (United States)

    Employment and Payroll Survey of Business Owners Work from Home Our statistics highlight trends in household statistics from multiple surveys. Data Tools & Apps Main American FactFinder Census Business Builder My ). Business Dynamics Statistics This tool shows tabulations on establishments, firms, and employment with

  9. Evaluating meeting support tools

    NARCIS (Netherlands)

    Post, W.M.; Huis in 't Veld, M. M.A.; Boogaard, S.A.A. van den

    2007-01-01

    Many attempts are underway for developing meeting support tools, but less attention is paid to the evaluation of meetingware. This article describes the development and testing of an instrument for evaluating meeting tools. First, we specified the object of evaluation -meetings- by means of a set of

  10. Maailma suurim tool

    Index Scriptorium Estoniae

    2000-01-01

    AS Tartu näitused, Tartu Kunstikool ja ajakiri 'Diivan' korraldavad 9.-11. III Tartu messikeskuse I paviljonis näituse 'Tool 2000'. Eksponeeritakse 2000 tooli, mille hulgast valitakse TOP 12. Messikeskuse territooriumile on kavas püstitada maailma suurim tool. Samal ajal II paviljonis kaksikmess 'Sisustus 2000' ja 'Büroo 2000'.

  11. Design mentoring tool.

    Science.gov (United States)

    2011-01-01

    In 2004 a design engineer on-line mentoring tool was developed and implemented The purpose of the tool was to assist senior engineers : mentoring new engineers to the INDOT design process and improve their technical competency. This approach saves se...

  12. Evaluating meeting support tools

    NARCIS (Netherlands)

    Post, W.M.; Huis in't Veld, M.A.A.; Boogaard, S.A.A. van den

    2008-01-01

    Many attempts are underway for developing meeting support tools, but less attention is paid to the evaluation of meetingware. This article describes the development and testing of an instrument for evaluating meeting tools. First, we specified the object of evaluation - meetings - by means of a set

  13. Tool Storage Problem Solved!

    Science.gov (United States)

    Klenke, Andrew M.; Dell, Tim W.

    2007-01-01

    Graduates of the automotive technology program at Pittsburg State University (PSU) generally enter the workforce in some type of automotive management role. As a result, the program does not require students to purchase their own tools, and it does not have room for all 280 majors to roll around a personal tool chest. Each instructor must maintain…

  14. Benchmarking Tool Kit.

    Science.gov (United States)

    Canadian Health Libraries Association.

    Nine Canadian health libraries participated in a pilot test of the Benchmarking Tool Kit between January and April, 1998. Although the Tool Kit was designed specifically for health libraries, the content and approach are useful to other types of libraries as well. Used to its full potential, benchmarking can provide a common measuring stick to…

  15. Expert tool use

    DEFF Research Database (Denmark)

    Thorndahl, Kathrine Liedtke; Ravn, Susanne

    2017-01-01

    on a case study of elite rope skipping, we argue that the phenomenological concept of incorporation does not suffice to adequately describe how expert tool users feel when interacting with their tools. By analyzing a combination of insights gained from participant observation of 11 elite rope skippers......According to some phenomenologists, a tool can be experienced as incorporated when, as a result of habitual use or deliberate practice, someone is able to manipulate it without conscious effort. In this article, we specifically focus on the experience of expertise tool use in elite sport. Based...... and autoethnographic material from one former elite skipper, we take some initial steps toward the development of a more nuanced understanding of the concept of incorporation; one that is able to accommodate the experiences of expert tool users. In sum, our analyses indicate that the possibility for experiencing...

  16. Language Management Tools

    DEFF Research Database (Denmark)

    Sanden, Guro Refsum

    This paper offers a review of existing literature on the topic of language management tools – the means by which language is managed – in multilingual organisations. By drawing on a combination of sociolinguistics and international business and management studies, a new taxonomy of language...... management tools is proposed, differentiating between three categories of tools. Firstly, corporate policies are the deliberate control of issues pertaining to language and communication developed at the managerial level of a firm. Secondly, corporate measures are the planned activities the firm’s leadership...... may deploy in order to address the language needs of the organisation. Finally, front-line practices refer to the use of informal, emergent language management tools available to staff members. The language management tools taxonomy provides a framework for operationalising the management of language...

  17. OOTW Force Design Tools

    Energy Technology Data Exchange (ETDEWEB)

    Bell, R.E.; Hartley, D.S.III; Packard, S.L.

    1999-05-01

    This report documents refined requirements for tools to aid the process of force design in Operations Other Than War (OOTWs). It recommends actions for the creation of one tool and work on other tools relating to mission planning. It also identifies the governmental agencies and commands with interests in each tool, from whom should come the user advisory groups overseeing the respective tool development activities. The understanding of OOTWs and their analytical support requirements has matured to the point where action can be taken in three areas: force design, collaborative analysis, and impact analysis. While the nature of the action and the length of time before complete results can be expected depends on the area, in each case the action should begin immediately. Force design for OOTWs is not a technically difficult process. Like force design for combat operations, it is a process of matching the capabilities of forces against the specified and implied tasks of the operation, considering the constraints of logistics, transport and force availabilities. However, there is a critical difference that restricts the usefulness of combat force design tools for OOTWs: the combat tools are built to infer non-combat capability requirements from combat capability requirements and cannot reverse the direction of the inference, as is required for OOTWs. Recently, OOTWs have played a larger role in force assessment, system effectiveness and tradeoff analysis, and concept and doctrine development and analysis. In the first Quadrennial Defense Review (QDR), each of the Services created its own OOTW force design tool. Unfortunately, the tools address different parts of the problem and do not coordinate the use of competing capabilities. These tools satisfied the immediate requirements of the QDR, but do not provide a long-term cost-effective solution.

  18. Electricity of machine tool

    International Nuclear Information System (INIS)

    Gijeon media editorial department

    1977-10-01

    This book is divided into three parts. The first part deals with electricity machine, which can taints from generator to motor, motor a power source of machine tool, electricity machine for machine tool such as switch in main circuit, automatic machine, a knife switch and pushing button, snap switch, protection device, timer, solenoid, and rectifier. The second part handles wiring diagram. This concludes basic electricity circuit of machine tool, electricity wiring diagram in your machine like milling machine, planer and grinding machine. The third part introduces fault diagnosis of machine, which gives the practical solution according to fault diagnosis and the diagnostic method with voltage and resistance measurement by tester.

  19. Machine tool evaluation

    International Nuclear Information System (INIS)

    Lunsford, B.E.

    1976-01-01

    Continued improvement in numerical control (NC) units and the mechanical components used in the construction of today's machine tools, necessitate the use of more precise instrumentation to calibrate and determine the capabilities of these systems. It is now necessary to calibrate most tape-control lathes to a tool-path positioning accuracy of +-300 microinches in the full slide travel and, on some special turning and boring machines, a capability of +-100 microinches must be achieved. The use of a laser interferometer to determine tool-path capabilities is described

  20. Machine Tool Software

    Science.gov (United States)

    1988-01-01

    A NASA-developed software package has played a part in technical education of students who major in Mechanical Engineering Technology at William Rainey Harper College. Professor Hack has been using (APT) Automatically Programmed Tool Software since 1969 in his CAD/CAM Computer Aided Design and Manufacturing curriculum. Professor Hack teaches the use of APT programming languages for control of metal cutting machines. Machine tool instructions are geometry definitions written in APT Language to constitute a "part program." The part program is processed by the machine tool. CAD/CAM students go from writing a program to cutting steel in the course of a semester.

  1. Game development tool essentials

    CERN Document Server

    Berinstein, Paula; Ardolino, Alessandro; Franco, Simon; Herubel, Adrien; McCutchan, John; Nedelcu, Nicusor; Nitschke, Benjamin; Olmstead, Don; Robinet, Fabrice; Ronchi, Christian; Turkowski, Rita; Walter, Robert; Samour, Gustavo

    2014-01-01

    Offers game developers new techniques for streamlining the critical game tools pipeline. Inspires game developers to share their secrets and improve the productivity of the entire industry. Helps game industry practitioners compete in a hyper-competitive environment.

  2. Tool Inventory and Replacement

    Science.gov (United States)

    Bear, W. Forrest

    1976-01-01

    Vocational agriculture teachers are encouraged to evaluate curriculum offerings, the new trends in business and industry, and develop a master tool purchase and replacement plan over a 3- to 5-year period. (HD)

  3. ATO Resource Tool -

    Data.gov (United States)

    Department of Transportation — Cru-X/ART is a shift management tool designed for?use by operational employees in Air Traffic Facilities.? Cru-X/ART is used for shift scheduling, shift sign in/out,...

  4. Water Budget Tool

    Science.gov (United States)

    If you're designing a new landscape or rethinking your current one, the WaterSense Water Budget Tool will tell you if you have designed a landscape that will use an appropriate amount of water for your climate.

  5. Neighborhood Mapping Tool

    Data.gov (United States)

    Department of Housing and Urban Development — This tool assists the public and Choice Neighborhoods applicants to prepare data to submit with their grant application by allowing applicants to draw the exact...

  6. Sequence History Update Tool

    Science.gov (United States)

    Khanampompan, Teerapat; Gladden, Roy; Fisher, Forest; DelGuercio, Chris

    2008-01-01

    The Sequence History Update Tool performs Web-based sequence statistics archiving for Mars Reconnaissance Orbiter (MRO). Using a single UNIX command, the software takes advantage of sequencing conventions to automatically extract the needed statistics from multiple files. This information is then used to populate a PHP database, which is then seamlessly formatted into a dynamic Web page. This tool replaces a previous tedious and error-prone process of manually editing HTML code to construct a Web-based table. Because the tool manages all of the statistics gathering and file delivery to and from multiple data sources spread across multiple servers, there is also a considerable time and effort savings. With the use of The Sequence History Update Tool what previously took minutes is now done in less than 30 seconds, and now provides a more accurate archival record of the sequence commanding for MRO.

  7. Microgrid Analysis Tools Summary

    Energy Technology Data Exchange (ETDEWEB)

    Jimenez, Antonio [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Haase, Scott G [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Mathur, Shivani [Formerly NREL

    2018-03-05

    The over-arching goal of the Alaska Microgrid Partnership is to reduce the use of total imported fuel into communities to secure all energy services by at least 50% in Alaska's remote microgrids without increasing system life cycle costs while also improving overall system reliability, security, and resilience. One goal of the Alaska Microgrid Partnership is to investigate whether a combination of energy efficiency and high-contribution (from renewable energy) power systems can reduce total imported energy usage by 50% while reducing life cycle costs and improving reliability and resiliency. This presentation provides an overview of the following four renewable energy optimization tools. Information is from respective tool websites, tool developers, and author experience. Distributed Energy Resources Customer Adoption Model (DER-CAM) Microgrid Design Toolkit (MDT) Renewable Energy Optimization (REopt) Tool Hybrid Optimization Model for Electric Renewables (HOMER).

  8. Financing Alternatives Comparison Tool

    Science.gov (United States)

    FACT is a financial analysis tool that helps identify the most cost-effective method to fund a wastewater or drinking water management project. It produces a comprehensive analysis that compares various financing options.

  9. Breastfeeding assessment tools

    International Nuclear Information System (INIS)

    Bizouerne, Cécile; Kerac, Marko; Macgrath, Marie

    2014-01-01

    Full text: Breastfeeding plays a major role in reducing the global burden of child mortality and under-nutrition. Whilst many programmes aim to support breastfeeding and prevent feeding problems occurring, interventions are also needed once they have developed. In this situation, accurate assessment of a problem is critical to inform prognosis and enables tailored, appropriate treatment. The presentation will present a review, which aims to identify breastfeeding assessment tools/checklists for use in assessing malnourished infants in poor resource settings. The literature review identified 24 breastfeeding assessment tools, and 41 validation studies. Evidence underpinning most of the tools was mainly low quality, and conducted in high-income countries and hospital settings. The presentation will describe the main findings of the literature review and propose recommendations for improving existing tools in order to appropriately assess malnourished infants and enable early, appropriate intervention and treatment of malnutrition. (author)

  10. Personal Wellness Tools

    Science.gov (United States)

    ... of Personal Stories Peers Celebrating Art Peers Celebrating Music Be Vocal Support Locator DBSA In-Person Support ... With this tool, you can track key health trends related to the following: Overall mood Mood disorder ...

  11. Cash Reconciliation Tool

    Data.gov (United States)

    US Agency for International Development — CART is a cash reconciliation tool that allows users to reconcile Agency cash disbursements with Treasury fund balances; track open unreconciled items; and create an...

  12. Chemical Data Access Tool

    Data.gov (United States)

    U.S. Environmental Protection Agency — This tool is intended to aid individuals interested in learning more about chemicals that are manufactured or imported into the United States. Health and safety...

  13. Tools and their uses

    CERN Document Server

    1973-01-01

    Teaches names, general uses, and correct operation of all basic hand and power tools, fasteners, and measuring devices you are likely to need. Also, grinding, metal cutting, soldering, and more. 329 illustrations.

  14. Chatter and machine tools

    CERN Document Server

    Stone, Brian

    2014-01-01

    Focussing on occurrences of unstable vibrations, or Chatter, in machine tools, this book gives important insights into how to eliminate chatter with associated improvements in product quality, surface finish and tool wear. Covering a wide range of machining processes, including turning, drilling, milling and grinding, the author uses his research expertise and practical knowledge of vibration problems to provide solutions supported by experimental evidence of their effectiveness. In addition, this book contains links to supplementary animation programs that help readers to visualise the ideas detailed in the text. Advancing knowledge in chatter avoidance and suggesting areas for new innovations, Chatter and Machine Tools serves as a handbook for those desiring to achieve significant reductions in noise, longer tool and grinding wheel life and improved product finish.

  15. Learning Design Tools

    NARCIS (Netherlands)

    Griffiths, David; Blat, Josep; Garcia, Rocío; Vogten, Hubert; Kwong, KL

    2005-01-01

    Griffiths, D., Blat, J., Garcia, R., Vogten, H. & Kwong, KL. (2005). Learning Design Tools. In: Koper, R. & Tattersall, C., Learning Design: A Handbook on Modelling and Delivering Networked Education and Training (pp. 109-136). Berlin-Heidelberg: Springer Verlag.

  16. Clean Energy Finance Tool

    Science.gov (United States)

    State and local governments interested in developing a financing program can use this Excel tool to support energy efficiency and clean energy improvements for large numbers of buildings within their jurisdiction.

  17. Mapping Medicare Disparities Tool

    Data.gov (United States)

    U.S. Department of Health & Human Services — The CMS Office of Minority Health has designed an interactive map, the Mapping Medicare Disparities Tool, to identify areas of disparities between subgroups of...

  18. Recovery Action Mapping Tool

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — The Recovery Action Mapping Tool is a web map that allows users to visually interact with and query actions that were developed to recover species listed under the...

  19. Friction stir welding tool

    Science.gov (United States)

    Tolle,; Charles R. , Clark; Denis E. , Barnes; Timothy, A [Ammon, ID

    2008-04-15

    A friction stir welding tool is described and which includes a shank portion; a shoulder portion which is releasably engageable with the shank portion; and a pin which is releasably engageable with the shoulder portion.

  20. CMS offline web tools

    International Nuclear Information System (INIS)

    Metson, S; Newbold, D; Belforte, S; Kavka, C; Bockelman, B; Dziedziniewicz, K; Egeland, R; Elmer, P; Eulisse, G; Tuura, L; Evans, D; Fanfani, A; Feichtinger, D; Kuznetsov, V; Lingen, F van; Wakefield, S

    2008-01-01

    We describe a relatively new effort within CMS to converge on a set of web based tools, using state of the art industry techniques, to engage with the CMS offline computing system. CMS collaborators require tools to monitor various components of the computing system and interact with the system itself. The current state of the various CMS web tools is described along side current planned developments. The CMS collaboration comprises of nearly 3000 people from all over the world. As well as its collaborators, its computing resources are spread all over globe and are accessed via the LHC grid to run analysis, large scale production and data transfer tasks. Due to the distributed nature of collaborators effective provision of collaborative tools is essential to maximise physics exploitation of the CMS experiment, especially when the size of the CMS data set is considered. CMS has chosen to provide such tools over the world wide web as a top level service, enabling all members of the collaboration to interact with the various offline computing components. Traditionally web interfaces have been added in HEP experiments as an afterthought. In the CMS offline we have decided to put web interfaces, and the development of a common CMS web framework, on an equal footing with the rest of the offline development. Tools exist within CMS to transfer and catalogue data (PhEDEx and DBS/DLS), run Monte Carlo production (ProdAgent) and submit analysis (CRAB). Effective human interfaces to these systems are required for users with different agendas and practical knowledge of the systems to effectively use the CMS computing system. The CMS web tools project aims to provide a consistent interface to all these tools

  1. Quality management tool

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Tae Hun

    2011-09-15

    This book introduces basic conception of quality with characteristic, price, cost, and function, basic conception on quality management, introduction and operation of quality management, quality guaranteed and claim like handling of claim of goods, standards, and quality guaranteed method, basic tools of quality management such as Pareto diagram, characteristic diagram, cause-and-effect, fish born diagram check sheet histogram scatter diagram graph and stratification new seven tools of QC, quality deployment function and measurement system.

  2. Quality management tool

    International Nuclear Information System (INIS)

    Lee, Tae Hun

    2011-09-01

    This book introduces basic conception of quality with characteristic, price, cost, and function, basic conception on quality management, introduction and operation of quality management, quality guaranteed and claim like handling of claim of goods, standards, and quality guaranteed method, basic tools of quality management such as Pareto diagram, characteristic diagram, cause-and-effect, fish born diagram check sheet histogram scatter diagram graph and stratification new seven tools of QC, quality deployment function and measurement system.

  3. Stochastic tools in turbulence

    CERN Document Server

    Lumey, John L

    2012-01-01

    Stochastic Tools in Turbulence discusses the available mathematical tools to describe stochastic vector fields to solve problems related to these fields. The book deals with the needs of turbulence in relation to stochastic vector fields, particularly, on three-dimensional aspects, linear problems, and stochastic model building. The text describes probability distributions and densities, including Lebesgue integration, conditional probabilities, conditional expectations, statistical independence, lack of correlation. The book also explains the significance of the moments, the properties of the

  4. CMS offline web tools

    Energy Technology Data Exchange (ETDEWEB)

    Metson, S; Newbold, D [H.H. Wills Physics Laboratory, University of Bristol, Tyndall Avenue, Bristol BS8 1TL (United Kingdom); Belforte, S; Kavka, C [INFN, Sezione di Trieste (Italy); Bockelman, B [University of Nebraska Lincoln, Lincoln, NE (United States); Dziedziniewicz, K [CERN, Geneva (Switzerland); Egeland, R [University of Minnesota Twin Cities, Minneapolis, MN (United States); Elmer, P [Princeton (United States); Eulisse, G; Tuura, L [Northeastern University, Boston, MA (United States); Evans, D [Fermilab MS234, Batavia, IL (United States); Fanfani, A [Universita degli Studi di Bologna (Italy); Feichtinger, D [PSI, Villigen (Switzerland); Kuznetsov, V [Cornell University, Ithaca, NY (United States); Lingen, F van [California Institute of Technology, Pasedena, CA (United States); Wakefield, S [Blackett Laboratory, Imperial College, London (United Kingdom)

    2008-07-15

    We describe a relatively new effort within CMS to converge on a set of web based tools, using state of the art industry techniques, to engage with the CMS offline computing system. CMS collaborators require tools to monitor various components of the computing system and interact with the system itself. The current state of the various CMS web tools is described along side current planned developments. The CMS collaboration comprises of nearly 3000 people from all over the world. As well as its collaborators, its computing resources are spread all over globe and are accessed via the LHC grid to run analysis, large scale production and data transfer tasks. Due to the distributed nature of collaborators effective provision of collaborative tools is essential to maximise physics exploitation of the CMS experiment, especially when the size of the CMS data set is considered. CMS has chosen to provide such tools over the world wide web as a top level service, enabling all members of the collaboration to interact with the various offline computing components. Traditionally web interfaces have been added in HEP experiments as an afterthought. In the CMS offline we have decided to put web interfaces, and the development of a common CMS web framework, on an equal footing with the rest of the offline development. Tools exist within CMS to transfer and catalogue data (PhEDEx and DBS/DLS), run Monte Carlo production (ProdAgent) and submit analysis (CRAB). Effective human interfaces to these systems are required for users with different agendas and practical knowledge of the systems to effectively use the CMS computing system. The CMS web tools project aims to provide a consistent interface to all these tools.

  5. Tools used for hand deburring

    Energy Technology Data Exchange (ETDEWEB)

    Gillespie, L.K.

    1981-03-01

    This guide is designed to help in quick identification of those tools most commonly used to deburr hand size or smaller parts. Photographs and textual descriptions are used to provide rapid yet detailed information. The data presented include the Bendix Kansas City Division coded tool number, tool description, tool crib in which the tool can be found, the maximum and minimum inventory requirements, the cost of each tool, and the number of the illustration that shows the tool.

  6. Physics analysis tools

    International Nuclear Information System (INIS)

    Kunz, P.F.

    1991-04-01

    There are many tools used in analysis in High Energy Physics (HEP). They range from low level tools such as a programming language to high level such as a detector simulation package. This paper will discuss some aspects of these tools that are directly associated with the process of analyzing HEP data. Physics analysis tools cover the whole range from the simulation of the interactions of particles to the display and fitting of statistical data. For purposes of this paper, the stages of analysis is broken down to five main stages. The categories are also classified as areas of generation, reconstruction, and analysis. Different detector groups use different terms for these stages thus it is useful to define what is meant by them in this paper. The particle generation stage is a simulation of the initial interaction, the production of particles, and the decay of the short lived particles. The detector simulation stage simulates the behavior of an event in a detector. The track reconstruction stage does pattern recognition on the measured or simulated space points, calorimeter information, etc., and reconstructs track segments of the original event. The event reconstruction stage takes the reconstructed tracks, along with particle identification information and assigns masses to produce 4-vectors. Finally the display and fit stage displays statistical data accumulated in the preceding stages in the form of histograms, scatter plots, etc. The remainder of this paper will consider what analysis tools are available today, and what one might expect in the future. In each stage, the integration of the tools with other stages and the portability of the tool will be analyzed

  7. New Conceptual Design Tools

    DEFF Research Database (Denmark)

    Pugnale, Alberto; Holst, Malene Kirstine; Kirkegaard, Poul Henning

    2010-01-01

    hand, the main software houses are trying to introduce powerful and effective user-friendly applications in the world of building designers, that are more and more able to fit their specific requirements; on the other hand, some groups of expert users with a basic programming knowledge seem to deal......This paper aims to discuss recent approaches in using more and more frequently computer tools as supports for the conceptual design phase of the architectural project. The present state-of-the-art about software as conceptual design tool could be summarized in two parallel tendencies. On the one...... with the problem of software as conceptual design tool by means of 'scripting', in other words by self-developing codes able to solve specific and well defined design problems. Starting with a brief historical recall and the discussion of relevant researches and practical experiences, this paper investigates...

  8. Assembly tool design

    International Nuclear Information System (INIS)

    Kanamori, Naokazu; Nakahira, Masataka; Ohkawa, Yoshinao; Tada, Eisuke; Seki, Masahiro

    1996-06-01

    The reactor core of the International Thermonuclear Experimental Reactor (ITER) is assembled with a number of large and asymmetric components within a tight tolerance in order to assure the structural integrity for various loads and to provide the tritium confinement. In addition, the assembly procedure should be compatible with remote operation since the core structures will be activated by 14-MeV neutrons once it starts operation and thus personal access will be prohibited. Accordingly, the assembly procedure and tool design are quite essential and should be designed from the beginning to facilitate remote operation. According to the ITER Design Task Agreement, the Japan Atomic Energy Research Institute (JAERI) has performed design study to develop the assembly procedures and associated tool design for the ITER tokamak assembly. This report describes outlines of the assembly tools and the remaining issues obtained in this design study. (author)

  9. RSP Tooling Technology

    Energy Technology Data Exchange (ETDEWEB)

    None

    2001-11-20

    RSP Tooling{trademark} is a spray forming technology tailored for producing molds and dies. The approach combines rapid solidification processing and net-shape materials processing in a single step. The general concept involves converting a mold design described by a CAD file to a tooling master using a suitable rapid prototyping (RP) technology such as stereolithography. A pattern transfer is made to a castable ceramic, typically alumina or fused silica (Figure 1). This is followed by spray forming a thick deposit of a tooling alloy on the pattern to capture the desired shape, surface texture, and detail. The resultant metal block is cooled to room temperature and separated from the pattern. The deposit's exterior walls are machined square, allowing it to be used as an insert in a standard mold base. The overall turnaround time for tooling is about 3 to 5 days, starting with a master. Molds and dies produced in this way have been used in high volume production runs in plastic injection molding and die casting. A Cooperative Research and Development Agreement (CRADA) between the Idaho National Engineering and Environmental Laboratory (INEEL) and Grupo Vitro has been established to evaluate the feasibility of using RSP Tooling technology for producing molds and dies of interest to Vitro. This report summarizes results from Phase I of this agreement, and describes work scope and budget for Phase I1 activities. The main objective in Phase I was to demonstrate the feasibility of applying the Rapid Solidification Process (RSP) Tooling method to produce molds for the manufacture of glass and other components of interest to Vitro. This objective was successfully achieved.

  10. CMS tracker visualization tools

    CERN Document Server

    Zito, G; Osborne, I; Regano, A

    2005-01-01

    This document will review the design considerations, implementations and performance of the CMS Tracker Visualization tools. In view of the great complexity of this sub-detector (more than 50 millions channels organized in 16540 modules each one of these being a complete detector), the standard CMS visualization tools (IGUANA and IGUANACMS) that provide basic 3D capabilities and integration within CMS framework, respectively, have been complemented with additional 2D graphics objects. Based on the experience acquired using this software to debug and understand both hardware and software during the construction phase, we propose possible future improvements to cope with online monitoring and event analysis during data taking.

  11. CMS tracker visualization tools

    Energy Technology Data Exchange (ETDEWEB)

    Mennea, M.S. [Dipartimento Interateneo di Fisica ' Michelangelo Merlin' e INFN sezione di Bari, Via Amendola 173 - 70126 Bari (Italy); Osborne, I. [Northeastern University, 360 Huntington Avenue, Boston, MA 02115 (United States); Regano, A. [Dipartimento Interateneo di Fisica ' Michelangelo Merlin' e INFN sezione di Bari, Via Amendola 173 - 70126 Bari (Italy); Zito, G. [Dipartimento Interateneo di Fisica ' Michelangelo Merlin' e INFN sezione di Bari, Via Amendola 173 - 70126 Bari (Italy)]. E-mail: giuseppe.zito@ba.infn.it

    2005-08-21

    This document will review the design considerations, implementations and performance of the CMS Tracker Visualization tools. In view of the great complexity of this sub-detector (more than 50 millions channels organized in 16540 modules each one of these being a complete detector), the standard CMS visualization tools (IGUANA and IGUANACMS) that provide basic 3D capabilities and integration within CMS framework, respectively, have been complemented with additional 2D graphics objects. Based on the experience acquired using this software to debug and understand both hardware and software during the construction phase, we propose possible future improvements to cope with online monitoring and event analysis during data taking.

  12. The GNEMRE Dendro Tool.

    Energy Technology Data Exchange (ETDEWEB)

    Merchant, Bion John

    2007-10-01

    The GNEMRE Dendro Tool provides a previously unrealized analysis capability in the field of nuclear explosion monitoring. Dendro Tool allows analysts to quickly and easily determine the similarity between seismic events using the waveform time-series for each of the events to compute cross-correlation values. Events can then be categorized into clusters of similar events. This analysis technique can be used to characterize historical archives of seismic events in order to determine many of the unique sources that are present. In addition, the source of any new events can be quickly identified simply by comparing the new event to the historical set.

  13. Authoring Issues beyond Tools

    Science.gov (United States)

    Spierling, Ulrike; Szilas, Nicolas

    Authoring is still considered a bottleneck in successful Interactive Storytelling and Drama. The claim for intuitive authoring tools is high, especially for tools that allow storytellers and artists to define dynamic content that can be run with an AI-based story engine. We explored two concrete authoring processes in depth, using various Interactive Storytelling prototypes, and have provided feedback from the practical steps. The result is a presentation of general issues in authoring Interactive Storytelling, rather than of particular problems with a specific system that could be overcome by 'simply' designing the right interface. Priorities for future developments are also outlined.

  14. CMS tracker visualization tools

    International Nuclear Information System (INIS)

    Mennea, M.S.; Osborne, I.; Regano, A.; Zito, G.

    2005-01-01

    This document will review the design considerations, implementations and performance of the CMS Tracker Visualization tools. In view of the great complexity of this sub-detector (more than 50 millions channels organized in 16540 modules each one of these being a complete detector), the standard CMS visualization tools (IGUANA and IGUANACMS) that provide basic 3D capabilities and integration within CMS framework, respectively, have been complemented with additional 2D graphics objects. Based on the experience acquired using this software to debug and understand both hardware and software during the construction phase, we propose possible future improvements to cope with online monitoring and event analysis during data taking

  15. Coach assessment tool

    OpenAIRE

    Härkönen, Niko; Klicznik, Roman

    2014-01-01

    The Coach Assessment Tool was created to assist coaches of all sports for their own development. The starting point to develop the tool is the fact that coaching clinics solely focus on the technical and tactial skills of the sport. The education for coaches is lacking to teach the importance of the coach´s behavior towards their athletes. The question is how to teach properly the task in hand to increase the athlete´s performance considering the coach´s behavior. Nevertheless,...

  16. Cancer Data and Statistics Tools

    Science.gov (United States)

    ... Educational Campaigns Initiatives Stay Informed Cancer Data and Statistics Tools Recommend on Facebook Tweet Share Compartir Cancer Statistics Tools United States Cancer Statistics: Data Visualizations The ...

  17. Incident Information Management Tool

    CERN Document Server

    Pejovic, Vladimir

    2015-01-01

    Flaws of\tcurrent incident information management at CMS and CERN\tare discussed. A new data\tmodel for future incident database is\tproposed and briefly described. Recently developed draft version of GIS-­‐based tool for incident tracking is presented.

  18. Hypercard Another Computer Tool.

    Science.gov (United States)

    Geske, Joel

    1991-01-01

    Describes "Hypercard," a computer application package usable in all three modes of instructional computing: tutor, tool, and tutee. Suggests using Hypercard in scholastic journalism programs to teach such topics as news, headlines, design, photography, and advertising. Argues that the ability to access, organize, manipulate, and comprehend…

  19. Organisational skills and tools.

    Science.gov (United States)

    Wicker, Paul

    2009-04-01

    While this article mainly applies to practitioners who have responsibilities for leading teams or supervising practitioners, many of the skills and tools described here may also apply to students or junior practitioners. The purpose of this article is to highlight some of the main points about organisation, some of the organisational skills and tools that are available, and some examples of how these skills and tools can be used to make practitioners more effective at organising their workload. It is important to realise that organising work and doing work are two completely different things and shouldn't be mixed up. For example, it would be very difficult to start organising work in the middle of a busy operating list: the organisation of the work must come before the work starts and therefore preparation is often an important first step in organising work. As such, some of the tools and skills described in this article may need to be used hours or even days prior to the actual work taking place.

  20. Tools for Authentication

    International Nuclear Information System (INIS)

    White, G.

    2008-01-01

    Many recent Non-proliferation and Arms Control software projects include a software authentication component. In this context, 'authentication' is defined as determining that a software package performs only its intended purpose and performs that purpose correctly and reliably over many years. In addition to visual inspection by knowledgeable computer scientists, automated tools are needed to highlight suspicious code constructs both to aid the visual inspection and to guide program development. While many commercial tools are available for portions of the authentication task, they are proprietary, and have limited extensibility. An open-source, extensible tool can be customized to the unique needs of each project (projects can have both common and custom rules to detect flaws and security holes). Any such extensible tool must be based on a complete language compiler infrastructure, that is, one that can parse and digest the full language through its standard grammar. ROSE is precisely such a compiler infrastructure developed within DOE. ROSE is a robust source-to-source analysis and optimization infrastructure currently addressing large, million-line DOE applications in C, C++, and FORTRAN. This year, it has been extended to support the automated analysis of binaries. We continue to extend ROSE to address a number of security-specific requirements and apply it to software authentication for Non-proliferation and Arms Control projects. We will give an update on the status of our work

  1. Methodologies, languages and tools

    International Nuclear Information System (INIS)

    Amako, Katsuya

    1994-01-01

    This is a summary of the open-quotes Methodologies, Languages and Toolsclose quotes session in the CHEP'94 conference. All the contributions to methodologies and languages are relevant to the object-oriented approach. Other topics presented are related to various software tools in the down-sized computing environment

  2. Tools for Authentication

    Energy Technology Data Exchange (ETDEWEB)

    White, G

    2008-07-09

    Many recent Non-proliferation and Arms Control software projects include a software authentication component. In this context, 'authentication' is defined as determining that a software package performs only its intended purpose and performs that purpose correctly and reliably over many years. In addition to visual inspection by knowledgeable computer scientists, automated tools are needed to highlight suspicious code constructs both to aid the visual inspection and to guide program development. While many commercial tools are available for portions of the authentication task, they are proprietary, and have limited extensibility. An open-source, extensible tool can be customized to the unique needs of each project (projects can have both common and custom rules to detect flaws and security holes). Any such extensible tool must be based on a complete language compiler infrastructure, that is, one that can parse and digest the full language through its standard grammar. ROSE is precisely such a compiler infrastructure developed within DOE. ROSE is a robust source-to-source analysis and optimization infrastructure currently addressing large, million-line DOE applications in C, C++, and FORTRAN. This year, it has been extended to support the automated analysis of binaries. We continue to extend ROSE to address a number of security-specific requirements and apply it to software authentication for Non-proliferation and Arms Control projects. We will give an update on the status of our work.

  3. [Tools for assisting diagnosis].

    Science.gov (United States)

    Roux, Magali; Asset, Sonya; Medjebar, Samir

    2017-11-01

    Connected objects are revolutionising practices, fulfil patients' needs for autonomy and the need to deploy healthcare provision beyond healthcare facilities. This article illustrates how these tools can be used in the case of epilepsy. Copyright © 2017 Elsevier Masson SAS. All rights reserved.

  4. Requirements for enrichment tools

    NARCIS (Netherlands)

    Boer, A.; Winkels, R.; Trompper, M.

    2016-01-01

    This report gives a high level overview of requirements for Enrichment tools in the Openlaws.eu project. Openlaws.eu aims to initiate a platform and develop a vision for Big Open Legal Data (BOLD): an open framework for legislation, case law, and legal literature from across Europe.

  5. C-TOOL

    DEFF Research Database (Denmark)

    Taghizadeh-Toosi, Arezoo; Christensen, Bent Tolstrup; Hutchings, Nicholas John

    2014-01-01

    Soil organic carbon (SOC) is a significant component of the global carbon (C) cycle. Changes in SOC storage affect atmospheric CO2 concentrations on decadal to centennial timescales. The C-TOOL model was developed to simulate farm- and regional-scale effects of management on medium- to long...

  6. Tools for Climate Services

    Science.gov (United States)

    Hartmann, H. C.

    2007-05-01

    Full realization of socio-economic benefits of from public investments in climate services remains incomplete because decision makers have difficulty: 1) interpreting individual products, 2) appropriately judging information credibility, and 3) linking different types of information, both conceptually and practically. Addressing these barriers is as important as improving the science leading to improved information. The challenge is creating flexible climate information products and tools that can accommodate unique user needs; the goal is a systemic change in the nature of information delivery and use. The underlying assumption is not that climate information is good and useful, and simply needs to be communicated effectively. Rather, a number of conditions must be met before decision makers can make informed choices about whether to use particular information in a specific situation. Several case studies, of varying success, illustrate user-centric strategies for developing decision support tools: a forecast evaluation tool, a climate information management system, and a hydrologic alert system. However, tools alone will not bridge the barriers in climate services, with training and other capacity- building activities remaining important activities.

  7. Sight Application Analysis Tool

    Energy Technology Data Exchange (ETDEWEB)

    Bronevetsky, G. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States)

    2014-09-17

    The scale and complexity of scientific applications makes it very difficult to optimize, debug and extend them to support new capabilities. We have developed a tool that supports developers’ efforts to understand the logical flow of their applications and interactions between application components and hardware in a way that scales with application complexity and parallelism.

  8. Tool voor verdeling rivierwater

    NARCIS (Netherlands)

    Hellegers, P.J.G.J.

    2011-01-01

    In het stroomgebied van de Inkomati-rivier in zuidelijk Afrika, maken partijen uit drie landen aanspraak op het rivierwater. LEI, Alterra en adviesbureau WaterWatch ontwikkelden met lokale partners een tool die betrokkenen laat zien wat ander landgebruik betekent voor de beschikbaarheid van dat

  9. The science writing tool

    Science.gov (United States)

    Schuhart, Arthur L.

    This is a two-part dissertation. The primary part is the text of a science-based composition rhetoric and reader called The Science Writing Tool. This textbook has seven chapters dealing with topics in Science Rhetoric. Each chapter includes a variety of examples of science writing, discussion questions, writing assignments, and instructional resources. The purpose of this text is to introduce lower-division college science majors to the role that rhetoric and communication plays in the conduct of Science, and how these skills contribute to a successful career in Science. The text is designed as a "tool kit," for use by an instructor constructing a science-based composition course or a writing-intensive Science course. The second part of this part of this dissertation reports on student reactions to draft portions of The Science Writing Tool text. In this report, students of English Composition II at Northern Virginia Community College-Annandale were surveyed about their attitudes toward course materials and topics included. The findings were used to revise and expand The Science Writing Tool.

  10. Big Data Visualization Tools

    OpenAIRE

    Bikakis, Nikos

    2018-01-01

    Data visualization is the presentation of data in a pictorial or graphical format, and a data visualization tool is the software that generates this presentation. Data visualization provides users with intuitive means to interactively explore and analyze data, enabling them to effectively identify interesting patterns, infer correlations and causalities, and supports sense-making activities.

  11. Rapid Tooling via Stereolithography

    OpenAIRE

    Montgomery, Eva

    2006-01-01

    Approximately three years ago, composite stereolithography (SL) resins were introduced to the marketplace, offering performance features beyond what traditional SL resins could offer. In particular, the high heat deflection temperatures and high stiffness of these highly filled resins have opened the door to several new rapid prototyping (RP) applications, including wind tunnel test modelling and, more recently, rapid tooling.

  12. Tools of the Trade

    Science.gov (United States)

    Porterfield, Kitty; Carnes, Meg

    2010-01-01

    People have known principals who are intellectual giants on issues of instruction and who have a great love of children but who stumble in leadership roles because they either do not or cannot communicate what they know. Good communication skills are among the most important tools a leader carries in his or her toolbox. Not only does good…

  13. Verification of Simulation Tools

    International Nuclear Information System (INIS)

    Richard, Thierry

    2015-01-01

    Before qualifying a simulation tool, the requirements shall first be clearly identified, i.e.: - What type of study needs to be carried out? - What phenomena need to be modeled? This phase involves writing a precise technical specification. Once the requirements are defined, the most adapted product shall be selected from the various software options available on the market. Before using a particular version of a simulation tool to support the demonstration of nuclear safety studies, the following requirements shall be met. - An auditable quality assurance process complying with development international standards shall be developed and maintained, - A process of verification and validation (V and V) shall be implemented. This approach requires: writing a report and/or executive summary of the V and V activities, defining a validated domain (domain in which the difference between the results of the tools and those of another qualified reference is considered satisfactory for its intended use). - Sufficient documentation shall be available, - A detailed and formal description of the product (software version number, user configuration, other settings and parameters) in the targeted computing environment shall be available. - Source codes corresponding to the software shall be archived appropriately. When these requirements are fulfilled, the version of the simulation tool shall be considered qualified for a defined domain of validity, in a given computing environment. The functional verification shall ensure that: - the computer architecture of the tool does not include errors, - the numerical solver correctly represents the physical mathematical model, - equations are solved correctly. The functional verification can be demonstrated through certification or report of Quality Assurance. The functional validation shall allow the user to ensure that the equations correctly represent the physical phenomena in the perimeter of intended use. The functional validation can

  14. Extended Testability Analysis Tool

    Science.gov (United States)

    Melcher, Kevin; Maul, William A.; Fulton, Christopher

    2012-01-01

    The Extended Testability Analysis (ETA) Tool is a software application that supports fault management (FM) by performing testability analyses on the fault propagation model of a given system. Fault management includes the prevention of faults through robust design margins and quality assurance methods, or the mitigation of system failures. Fault management requires an understanding of the system design and operation, potential failure mechanisms within the system, and the propagation of those potential failures through the system. The purpose of the ETA Tool software is to process the testability analysis results from a commercial software program called TEAMS Designer in order to provide a detailed set of diagnostic assessment reports. The ETA Tool is a command-line process with several user-selectable report output options. The ETA Tool also extends the COTS testability analysis and enables variation studies with sensor sensitivity impacts on system diagnostics and component isolation using a single testability output. The ETA Tool can also provide extended analyses from a single set of testability output files. The following analysis reports are available to the user: (1) the Detectability Report provides a breakdown of how each tested failure mode was detected, (2) the Test Utilization Report identifies all the failure modes that each test detects, (3) the Failure Mode Isolation Report demonstrates the system s ability to discriminate between failure modes, (4) the Component Isolation Report demonstrates the system s ability to discriminate between failure modes relative to the components containing the failure modes, (5) the Sensor Sensor Sensitivity Analysis Report shows the diagnostic impact due to loss of sensor information, and (6) the Effect Mapping Report identifies failure modes that result in specified system-level effects.

  15. Spray-formed tooling

    Science.gov (United States)

    McHugh, K. M.; Key, J. F.

    The United States Council for Automotive Research (USCAR) has formed a partnership with the Idaho National Engineering Laboratory (INEL) to develop a process for the rapid production of low-cost tooling based on spray forming technology developed at the INEL. Phase 1 of the program will involve bench-scale system development, materials characterization, and process optimization. In Phase 2, prototype systems will be designed, constructed, evaluated, and optimized. Process control and other issues that influence commercialization will be addressed during this phase of the project. Technology transfer to USCAR, or a tooling vendor selected by USCAR, will be accomplished during Phase 3. The approach INEL is using to produce tooling, such as plastic injection molds and stamping dies, combines rapid solidification processing and net-shape materials processing into a single step. A bulk liquid metal is pressure-fed into a de Laval spray nozzle transporting a high velocity, high temperature inert gas. The gas jet disintegrates the metal into fine droplets and deposits them onto a tool pattern made from materials such as plastic, wax, clay, ceramics, and metals. The approach is compatible with solid freeform fabrication techniques such as stereolithography, selective laser sintering, and laminated object manufacturing. Heat is extracted rapidly, in-flight, by convection as the spray jet entrains cool inert gas to produce undercooled and semi-solid droplets. At the pattern, the droplets weld together while replicating the shape and surface features of the pattern. Tool formation is rapid; deposition rates in excess of 1 ton/h have been demonstrated for bench-scale nozzles.

  16. Web Tools: The Second Generation

    Science.gov (United States)

    Pascopella, Angela

    2008-01-01

    Web 2.0 tools and technologies, or second generation tools, help districts to save time and money, and eliminate the need to transfer or move files back and forth across computers. Many Web 2.0 tools help students think critically and solve problems, which falls under the 21st-century skills. The second-generation tools are growing in popularity…

  17. Pneumatic soil removal tool

    International Nuclear Information System (INIS)

    Neuhaus, J.E.

    1992-01-01

    A soil removal tool is provided for removing radioactive soil, rock and other debris from the bottom of an excavation, while permitting the operator to be located outside of a containment for that excavation. The tool includes a fixed jaw, secured to one end of an elongate pipe, which cooperates with a movable jaw pivotably mounted on the pipe. Movement of the movable jaw is controlled by a pneumatic cylinder mounted on the pipe. The actuator rod of the pneumatic cylinder is connected to a collar which is slidably mounted on the pipe and forms part of the pivotable mounting assembly for the movable jaw. Air is supplied to the pneumatic cylinder through a handle connected to the pipe, under the control of an actuator valve mounted on the handle, to provide movement of the movable jaw. 3 figs

  18. Building energy analysis tool

    Science.gov (United States)

    Brackney, Larry; Parker, Andrew; Long, Nicholas; Metzger, Ian; Dean, Jesse; Lisell, Lars

    2016-04-12

    A building energy analysis system includes a building component library configured to store a plurality of building components, a modeling tool configured to access the building component library and create a building model of a building under analysis using building spatial data and using selected building components of the plurality of building components stored in the building component library, a building analysis engine configured to operate the building model and generate a baseline energy model of the building under analysis and further configured to apply one or more energy conservation measures to the baseline energy model in order to generate one or more corresponding optimized energy models, and a recommendation tool configured to assess the one or more optimized energy models against the baseline energy model and generate recommendations for substitute building components or modifications.

  19. Remote vehicle survey tool

    International Nuclear Information System (INIS)

    Armstrong, G.A.; Burks, B.L.; Kress, R.L.; Wagner, D.G.; Ward, C.R.

    1993-01-01

    The Remote Vehicle Survey Tool (RVS7) is a color graphical display tool for viewing remotely acquired scientific data. The RVST displays the data in the form of a color two-dimensional world model map. The world model map allows movement of the remote vehicle to be tracked by the operator and the data from sensors to be graphically depicted in the interface. Linear and logarithmic meters, dual channel oscilloscopes, and directional compasses are used to display sensor information. The RVST is user-configurable by the use of ASCII text files. The operator can configure the RVST to work with any remote data acquisition system and teleoperated or autonomous vehicle. The modular design of the RVST and its ability to be quickly configured for varying system requirements make the RVST ideal for remote scientific data display in all environmental restoration and waste management programs

  20. Pneumatic soil removal tool

    Science.gov (United States)

    Neuhaus, John E.

    1992-01-01

    A soil removal tool is provided for removing radioactive soil, rock and other debris from the bottom of an excavation, while permitting the operator to be located outside of a containment for that excavation. The tool includes a fixed jaw, secured to one end of an elongate pipe, which cooperates with a movable jaw pivotably mounted on the pipe. Movement of the movable jaw is controlled by a pneumatic cylinder mounted on the pipe. The actuator rod of the pneumatic cylinder is connected to a collar which is slidably mounted on the pipe and forms part of the pivotable mounting assembly for the movable jaw. Air is supplied to the pneumatic cylinder through a handle connected to the pipe, under the control of an actuator valve mounted on the handle, to provide movement of the movable jaw.

  1. Communication tools in Canada

    International Nuclear Information System (INIS)

    Cowper, D.

    1995-01-01

    This document deals with the means and tools that are used for communicating with elected representatives. First, messages need to be simple, few in number and accurate. It is also advised to seek a first briefing because there is some information to be given, and not because some help is needed. On top of that, contacts should be made often enough to assure of a continued interest. (TEC)

  2. The GEDI Performance Tool

    Science.gov (United States)

    Hancock, S.; Armston, J.; Tang, H.; Patterson, P. L.; Healey, S. P.; Marselis, S.; Duncanson, L.; Hofton, M. A.; Kellner, J. R.; Luthcke, S. B.; Sun, X.; Blair, J. B.; Dubayah, R.

    2017-12-01

    NASA's Global Ecosystem Dynamics Investigation will mount a multi-track, full-waveform lidar on the International Space Station (ISS) that is optimised for the measurement of forest canopy height and structure. GEDI will use ten laser tracks, two 10 mJ "power beams" and eight 5 mJ "coverage beams" to produce global (51.5oS to 51.5oN) maps of above ground biomass (AGB), canopy height, vegetation structure and other biophysical parameters. The mission has a requirement to generate a 1 km AGB map with 80% of pixels with ≤ 20% standard error or 20 Mg·ha-1, whichever is greater. To assess performance and compare to mission requirements, an end-to-end simulator has been developed. The simulator brings together tools to propagate the effects of measurement and sampling error on GEDI data products. The simulator allows us to evaluate the impact of instrument performance, ISS orbits, processing algorithms and losses of data that may occur due to clouds, snow, leaf-off conditions, and areas with an insufficient signal-to-noise ratio (SNR). By evaluating the consequences of operational decisions on GEDI data products, this tool provides a quantitative framework for decision-making and mission planning. Here we demonstrate the performance tool by using it to evaluate the trade-off between measurement and sampling error on the 1 km AGB data product. Results demonstrate that the use of coverage beams during the day (lowest GEDI SNR case) over very dense forests (>95% canopy cover) will result in some measurement bias. Omitting these low SNR cases increased the sampling error. Through this an SNR threshold for a given expected canopy cover can be set. The other applications of the performance tool are also discussed, such as assessing the impact of decisions made in the AGB modelling and signal processing stages on the accuracy of final data products.

  3. Program Management Tool

    Science.gov (United States)

    Gawadiak, Yuri; Wong, Alan; Maluf, David; Bell, David; Gurram, Mohana; Tran, Khai Peter; Hsu, Jennifer; Yagi, Kenji; Patel, Hemil

    2007-01-01

    The Program Management Tool (PMT) is a comprehensive, Web-enabled business intelligence software tool for assisting program and project managers within NASA enterprises in gathering, comprehending, and disseminating information on the progress of their programs and projects. The PMT provides planning and management support for implementing NASA programmatic and project management processes and requirements. It provides an online environment for program and line management to develop, communicate, and manage their programs, projects, and tasks in a comprehensive tool suite. The information managed by use of the PMT can include monthly reports as well as data on goals, deliverables, milestones, business processes, personnel, task plans, monthly reports, and budgetary allocations. The PMT provides an intuitive and enhanced Web interface to automate the tedious process of gathering and sharing monthly progress reports, task plans, financial data, and other information on project resources based on technical, schedule, budget, and management criteria and merits. The PMT is consistent with the latest Web standards and software practices, including the use of Extensible Markup Language (XML) for exchanging data and the WebDAV (Web Distributed Authoring and Versioning) protocol for collaborative management of documents. The PMT provides graphical displays of resource allocations in the form of bar and pie charts using Microsoft Excel Visual Basic for Application (VBA) libraries. The PMT has an extensible architecture that enables integration of PMT with other strategic-information software systems, including, for example, the Erasmus reporting system, now part of the NASA Integrated Enterprise Management Program (IEMP) tool suite, at NASA Marshall Space Flight Center (MSFC). The PMT data architecture provides automated and extensive software interfaces and reports to various strategic information systems to eliminate duplicative human entries and minimize data integrity

  4. Social Data Analytics Tool

    DEFF Research Database (Denmark)

    Hussain, Abid; Vatrapu, Ravi

    2014-01-01

    This paper presents the design, development and demonstrative case studies of the Social Data Analytics Tool, SODATO. Adopting Action Design Framework [1], the objective of SODATO [2] is to collect, store, analyze, and report big social data emanating from the social media engagement of and social...... media conversations about organizations. We report and discuss results from two demonstrative case studies that were conducted using SODATO and conclude with implications and future work....

  5. MICROCONTROLLER PIN CONFIGURATION TOOL

    OpenAIRE

    Bhaskar Joshi; F. Mohammed Rizwan; Dr. Rajashree Shettar

    2012-01-01

    Configuring the micro controller with large number of pins is tedious. Latest Infine on microcontroller contains more than 200 pins and each pin has classes of signals. Therefore the complexity of the microcontroller is growing. It evolves looking into thousands of pages of user manual. For a user it will take days to configure the microcontroller with the peripherals. We need an automated tool to configure the microcontroller so that the user can configure the microcontroller without having ...

  6. Fluid sampling tool

    Science.gov (United States)

    Garcia, A.R.; Johnston, R.G.; Martinez, R.K.

    1999-05-25

    A fluid sampling tool is described for sampling fluid from a container. The tool has a fluid collecting portion which is drilled into the container wall, thereby affixing it to the wall. The tool may have a fluid extracting section which withdraws fluid collected by the fluid collecting section. The fluid collecting section has a fluted shank with an end configured to drill a hole into a container wall. The shank has a threaded portion for tapping the borehole. The shank is threadably engaged to a cylindrical housing having an inner axial passageway sealed at one end by a septum. A flexible member having a cylindrical portion and a bulbous portion is provided. The housing can be slid into an inner axial passageway in the cylindrical portion and sealed to the flexible member. The bulbous portion has an outer lip defining an opening. The housing is clamped into the chuck of a drill, the lip of the bulbous section is pressed against a container wall until the shank touches the wall, and the user operates the drill. Wall shavings (kerf) are confined in a chamber formed in the bulbous section as it folds when the shank advances inside the container. After sufficient advancement of the shank, an o-ring makes a seal with the container wall. 6 figs.

  7. Frequency Response Analysis Tool

    Energy Technology Data Exchange (ETDEWEB)

    Etingov, Pavel V. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Kosterev, Dmitry [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Dai, T. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States)

    2014-12-01

    Frequency response has received a lot of attention in recent years at the national level, which culminated in the development and approval of North American Electricity Reliability Corporation (NERC) BAL-003-1 Frequency Response and Frequency Bias Setting Reliability Standard. This report is prepared to describe the details of the work conducted by Pacific Northwest National Laboratory (PNNL) in collaboration with the Bonneville Power Administration and Western Electricity Coordinating Council (WECC) Joint Synchronized Information Subcommittee (JSIS) to develop a frequency response analysis tool (FRAT). The document provides the details on the methodology and main features of the FRAT. The tool manages the database of under-frequency events and calculates the frequency response baseline. Frequency response calculations are consistent with frequency response measure (FRM) in NERC BAL-003-1 for an interconnection and balancing authority. The FRAT can use both phasor measurement unit (PMU) data, where available, and supervisory control and data acquisition (SCADA) data. The tool is also capable of automatically generating NERC Frequency Response Survey (FRS) forms required by BAL-003-1 Standard.

  8. Dynamic Contingency Analysis Tool

    Energy Technology Data Exchange (ETDEWEB)

    2016-01-14

    The Dynamic Contingency Analysis Tool (DCAT) is an open-platform and publicly available methodology to help develop applications that aim to improve the capabilities of power system planning engineers to assess the impact and likelihood of extreme contingencies and potential cascading events across their systems and interconnections. Outputs from the DCAT will help find mitigation solutions to reduce the risk of cascading outages in technically sound and effective ways. The current prototype DCAT implementation has been developed as a Python code that accesses the simulation functions of the Siemens PSS/E planning tool (PSS/E). It has the following features: It uses a hybrid dynamic and steady-state approach to simulating the cascading outage sequences that includes fast dynamic and slower steady-state events. It integrates dynamic models with protection scheme models for generation, transmission, and load. It models special protection systems (SPSs)/remedial action schemes (RASs) and automatic and manual corrective actions. Overall, the DCAT attempts to bridge multiple gaps in cascading-outage analysis in a single, unique prototype tool capable of automatically simulating and analyzing cascading sequences in real systems using multiprocessor computers.While the DCAT has been implemented using PSS/E in Phase I of the study, other commercial software packages with similar capabilities can be used within the DCAT framework.

  9. Fluid sampling tool

    Science.gov (United States)

    Garcia, Anthony R.; Johnston, Roger G.; Martinez, Ronald K.

    1999-05-25

    A fluid sampling tool for sampling fluid from a container. The tool has a fluid collecting portion which is drilled into the container wall, thereby affixing it to the wall. The tool may have a fluid extracting section which withdraws fluid collected by the fluid collecting section. The fluid collecting section has a fluted shank with an end configured to drill a hole into a container wall. The shank has a threaded portion for tapping the borehole. The shank is threadably engaged to a cylindrical housing having an inner axial passageway sealed at one end by a septum. A flexible member having a cylindrical portion and a bulbous portion is provided. The housing can be slid into an inner axial passageway in the cylindrical portion and sealed to the flexible member. The bulbous portion has an outer lip defining an opening. The housing is clamped into the chuck of a drill, the lip of the bulbous section is pressed against a container wall until the shank touches the wall, and the user operates the drill. Wall shavings (kerf) are confined in a chamber formed in the bulbous section as it folds when the shank advances inside the container. After sufficient advancement of the shank, an o-ring makes a seal with the container wall.

  10. APT: Aperture Photometry Tool

    Science.gov (United States)

    Laher, Russ

    2012-08-01

    Aperture Photometry Tool (APT) is software for astronomers and students interested in manually exploring the photometric qualities of astronomical images. It has a graphical user interface (GUI) which allows the image data associated with aperture photometry calculations for point and extended sources to be visualized and, therefore, more effectively analyzed. Mouse-clicking on a source in the displayed image draws a circular or elliptical aperture and sky annulus around the source and computes the source intensity and its uncertainty, along with several commonly used measures of the local sky background and its variability. The results are displayed and can be optionally saved to an aperture-photometry-table file and plotted on graphs in various ways using functions available in the software. APT is geared toward processing sources in a small number of images and is not suitable for bulk processing a large number of images, unlike other aperture photometry packages (e.g., SExtractor). However, APT does have a convenient source-list tool that enables calculations for a large number of detections in a given image. The source-list tool can be run either in automatic mode to generate an aperture photometry table quickly or in manual mode to permit inspection and adjustment of the calculation for each individual detection. APT displays a variety of useful graphs, including image histogram, and aperture slices, source scatter plot, sky scatter plot, sky histogram, radial profile, curve of growth, and aperture-photometry-table scatter plots and histograms. APT has functions for customizing calculations, including outlier rejection, pixel “picking” and “zapping,” and a selection of source and sky models. The radial-profile-interpolation source model, accessed via the radial-profile-plot panel, allows recovery of source intensity from pixels with missing data and can be especially beneficial in crowded fields.

  11. Highcrop picture tool

    OpenAIRE

    Fog, Erik

    2013-01-01

    Pictures give other impulses than words and numbers. With images, you can easily spot new opportunities. The Highcrop-tool allows for optimization of the organic arable farm based on picture-cards. The picture-cards are designed to make it easier and more inspiring to go close to the details of production. By using the picture-cards you can spot the areas, where there is a possibility to optimize the production system for better results in the future. Highcrop picture cards can be used to:...

  12. Jupiter Environment Tool

    Science.gov (United States)

    Sturm, Erick J.; Monahue, Kenneth M.; Biehl, James P.; Kokorowski, Michael; Ngalande, Cedrick,; Boedeker, Jordan

    2012-01-01

    The Jupiter Environment Tool (JET) is a custom UI plug-in for STK that provides an interface to Jupiter environment models for visualization and analysis. Users can visualize the different magnetic field models of Jupiter through various rendering methods, which are fully integrated within STK s 3D Window. This allows users to take snapshots and make animations of their scenarios with magnetic field visualizations. Analytical data can be accessed in the form of custom vectors. Given these custom vectors, users have access to magnetic field data in custom reports, graphs, access constraints, coverage analysis, and anywhere else vectors are used within STK.

  13. ANT Advanced Neural Tool

    Energy Technology Data Exchange (ETDEWEB)

    Labrador, I.; Carrasco, R.; Martinez, L.

    1996-07-01

    This paper describes a practical introduction to the use of Artificial Neural Networks. Artificial Neural Nets are often used as an alternative to the traditional symbolic manipulation and first order logic used in Artificial Intelligence, due the high degree of difficulty to solve problems that can not be handled by programmers using algorithmic strategies. As a particular case of Neural Net a Multilayer Perception developed by programming in C language on OS9 real time operating system is presented. A detailed description about the program structure and practical use are included. Finally, several application examples that have been treated with the tool are presented, and some suggestions about hardware implementations. (Author) 15 refs.

  14. ANT Advanced Neural Tool

    International Nuclear Information System (INIS)

    Labrador, I.; Carrasco, R.; Martinez, L.

    1996-01-01

    This paper describes a practical introduction to the use of Artificial Neural Networks. Artificial Neural Nets are often used as an alternative to the traditional symbolic manipulation and first order logic used in Artificial Intelligence, due the high degree of difficulty to solve problems that can not be handled by programmers using algorithmic strategies. As a particular case of Neural Net a Multilayer Perception developed by programming in C language on OS9 real time operating system is presented. A detailed description about the program structure and practical use are included. Finally, several application examples that have been treated with the tool are presented, and some suggestions about hardware implementations. (Author) 15 refs

  15. The histogramming tool hparse

    International Nuclear Information System (INIS)

    Nikulin, V.; Shabratova, G.

    2005-01-01

    A general-purpose package aimed to simplify the histogramming in the data analysis is described. The proposed dedicated language for writing the histogramming scripts provides an effective and flexible tool for definition of a complicated histogram set. The script is more transparent and much easier to maintain than corresponding C++ code. In the TTree analysis it could be a good complement to the TTreeViewer class: the TTreeViewer is used for choice of the required histogram/cut set, while the hparse enables one to generate a code for systematic analysis

  16. Contamination Analysis Tools

    Science.gov (United States)

    Brieda, Lubos

    2015-01-01

    This talk presents 3 different tools developed recently for contamination analysis:HTML QCM analyzer: runs in a web browser, and allows for data analysis of QCM log filesJava RGA extractor: can load in multiple SRS.ana files and extract pressure vs. time dataC++ Contamination Simulation code: 3D particle tracing code for modeling transport of dust particulates and molecules. Uses residence time to determine if molecules stick. Particulates can be sampled from IEST-STD-1246 and be accelerated by aerodynamic forces.

  17. Balancing the tools

    DEFF Research Database (Denmark)

    Leroyer, Patrick

    2009-01-01

    The purpose of this article is to describe the potential of a new combination of functions in lexicographic tools for tourists. So far lexicography has focused on the communicative information needs of tourists, i.e. helping tourists decide what to say in a number of specific tourist situations, ...... tourist situations, wherever and whenever needed. It is demonstrated how this type of objective knowledge, which is conventionally represented in tourist guides and on tourist web sites, could benefit from being arranged in a lexicographic design....

  18. Exploratory study on the effects of a robotic hand rehabilitation device on changes in grip strength and brain activity after stroke.

    Science.gov (United States)

    Pinter, Daniela; Pegritz, Sandra; Pargfrieder, Christa; Reiter, Gudrun; Wurm, Walter; Gattringer, Thomas; Linderl-Madrutter, Regina; Neuper, Claudia; Fazekas, Franz; Grieshofer, Peter; Enzinger, Christian

    2013-01-01

    The brain mechanisms underlying successful recovery of hand fuenction after stroke are still not fully understood, although functional MRI (fMRI) studies underline the importance of neuronal plasticity. We explored potential changes in brain activity in 7 patients with subacute to chronic stroke (69 ± 8 years) with moderate- to high-grade distal paresis of the upper limb (Motricity Index: 59.4) after standardized robotic finger-hand rehabilitation training, in addition to conventional rehabilitation therapy for 3 weeks. Behavioral and fMRI assessments were carried out before and after training to characterize changes in brain activity and behavior. The Motricity Index (pre: 59.4, post: 67.2, P hand increased significantly after rehabilitation. On fMRI, active movement of the affected (left) hand resulted in contralesional (ie, ipsilateral) activation of the primary sensorimotor cortex prior to rehabilitation. After rehabilitation, activation appeared "normalized," including the ipsilesional primary sensorimotor cortex and supplementary motor area (SMA). No changes and no abnormalities of activation maps were seen during movement of the unaffected hand. Subsequent region-of-interest analyses showed no significant ipsilesional activation increases after rehabilitation. Despite behavioral improvements, we failed to identify consistent patterns of functional reorganization in our sample. This warrants caution in the use of fMRI as a tool to explore neural plasticity in heterogeneous samples lacking sufficient statistical power.

  19. Heat exchanger tube tool

    International Nuclear Information System (INIS)

    Gugel, G.

    1976-01-01

    Certain types of heat-exchangers have tubes opening through a tube sheet to a manifold having an access opening offset from alignment with the tube ends. A tool for inserting a device, such as for inspection or repair, is provided for use in such instances. The tool is formed by a flexible guide tube insertable through the access opening and having an inner end provided with a connector for connection with the opening of the tube in which the device is to be inserted, and an outer end which remains outside of the chamber, the guide tube having adequate length for this arrangement. A flexible transport hose for internally transporting the device slides inside of the guide tube. This hose is long enough to slide through the guide tube, into the heat-exchanger tube, and through the latter to the extent required for the use of the device. The guide tube must be bent to reach the end of the heat-exchanger tube and the latter may be constructed with a bend, the hose carrying anit-friction elements at interspaced locations along its length to make it possible for the hose to negotiate such bends while sliding to the location where the use of the device is required

  20. Hydraulic release oil tool

    International Nuclear Information System (INIS)

    Mims, M.G.; Mueller, M.D.; Ehlinger, J.C.

    1992-01-01

    This patent describes a hydraulic release tool. It comprises a setting assembly; a coupling member for coupling to drill string or petroleum production components, the coupling member being a plurality of sockets for receiving the dogs in the extended position and attaching the coupling member the setting assembly; whereby the setting assembly couples to the coupling member by engagement of the dogs in the sockets of releases from and disengages the coupling member in movement of the piston from its setting to its reposition in response to a pressure in the body in exceeding the predetermined pressure; and a relief port from outside the body into its bore and means to prevent communication between the relief port and the bore of the body axially of the piston when the piston is in the setting position and to establish such communication upon movement of the piston from the setting position to the release position and reduce the pressure in the body bore axially of the piston, whereby the reduction of the pressure signals that the tool has released the coupling member

  1. FASTBUS simulation tools

    International Nuclear Information System (INIS)

    Dean, T.D.; Haney, M.J.

    1991-10-01

    A generalized model of a FASTBUS master is presented. The model is used with simulation tools to aid in the specification, design, and production of FASTBUS slave modules. The model provides a mechanism to interact with the electrical schematics and software models to predict performance. The model is written in the IEEE std 1076-1987 hardware description language VHDL. A model of the ATC logic is also presented. VHDL was chosen to provide portability to various platforms and simulation tools. The models, in conjunction with most commercially available simulators, will perform all of the transactions specified in IEEE std 960-1989. The models may be used to study the behavior of electrical schematics and other software models and detect violations of the FASTBUS protocol. For example, a hardware design of a slave module could be studied, protocol violations detected and corrected before committing money to prototype development. The master model accepts a stream of high level commands from an ASCII file to initiate FASTBUS transactions. The high level command language is based on the FASTBUS standard routines listed in IEEE std 1177-1989. Using this standard-based command language to direct the model of the master, hardware engineers can simulate FASTBUS transactions in the language used by physicists and programmers to operate FASTBUS systems. 15 refs., 6 figs

  2. Motif enrichment tool.

    Science.gov (United States)

    Blatti, Charles; Sinha, Saurabh

    2014-07-01

    The Motif Enrichment Tool (MET) provides an online interface that enables users to find major transcriptional regulators of their gene sets of interest. MET searches the appropriate regulatory region around each gene and identifies which transcription factor DNA-binding specificities (motifs) are statistically overrepresented. Motif enrichment analysis is currently available for many metazoan species including human, mouse, fruit fly, planaria and flowering plants. MET also leverages high-throughput experimental data such as ChIP-seq and DNase-seq from ENCODE and ModENCODE to identify the regulatory targets of a transcription factor with greater precision. The results from MET are produced in real time and are linked to a genome browser for easy follow-up analysis. Use of the web tool is free and open to all, and there is no login requirement. ADDRESS: http://veda.cs.uiuc.edu/MET/. © The Author(s) 2014. Published by Oxford University Press on behalf of Nucleic Acids Research.

  3. OMIRIS educational tool

    International Nuclear Information System (INIS)

    Dumont, X.; Artus, J.C.; Gonin, M.; Bidard, F.; Hickman, B.

    2004-01-01

    The biological effects of ionizing radiations are one of the most important issues for workers exposed to these radiations in nuclear plants. To deliver information to workers about this topic, the 'Utility Medical Work Officers' wanted an educational tool. This tool named 'OMIRIS' was prepared under the authority of the federation of professors in radiology, radiobiology and radioprotection and the industrial nuclear partners in France (ANDRA, AREVA/COGEMA and FRAMATOME-ANP, CEA and EDF). The use of animation techniques helps to present in a simple way this complex topic using an interactive, pleasant and comprehensible form. Detailed information is given about 5 themes: 1) the various sources of ionizing radiation whatever they are natural, medical, industrial or military; 2) the various types of exposure, whether internal or external, their characteristics: duration, target organs and radiological toxicity and the different means of protection; 3) the concept of dose, the importance of dose rate and the reference values of doses; 4) the biological effects on the human organism, notions of dose threshold and aims, results and limitations of epidemiological surveys; and 5) the regulation based on radiological protection studies

  4. Treatment Deployment Evaluation Tool

    International Nuclear Information System (INIS)

    M. A. Rynearson; M. M. Plum

    1999-01-01

    The U.S. Department of Energy (DOE) is responsible for the final disposition of legacy spent nuclear fuel (SNF). As a response, DOE's National Spent Nuclear Fuel Program (NSNFP) has been given the responsibility for the disposition of DOE-owned SNF. Many treatment technologies have been identified to treat some forms of SNF so that the resulting treated product is acceptable by the disposition site. One of these promising treatment processes is the electrometallurgical treatment (EMT) currently in development; a second is an Acid Wash Decladding process. The NSNFP has been tasked with identifying possible strategies for the deployment of these treatment processes in the event that a treatment path is deemed necessary. To support the siting studies of these strategies, economic evaluations are being performed to identify the least-cost deployment path. This model (tool) was developed to consider the full scope of costs, technical feasibility, process material disposition, and schedule attributes over the life of each deployment alternative. Using standard personal computer (PC) software, the model was developed as a comprehensive technology economic assessment tool using a Life-Cycle Cost (LCC) analysis methodology. Model development was planned as a systematic, iterative process of identifying and bounding the required activities to dispose of SNF. To support the evaluation process, activities are decomposed into lower level, easier to estimate activities. Sensitivity studies can then be performed on these activities, defining cost issues and testing results against the originally stated problem

  5. Tools for computational finance

    CERN Document Server

    Seydel, Rüdiger U

    2017-01-01

    Computational and numerical methods are used in a number of ways across the field of finance. It is the aim of this book to explain how such methods work in financial engineering. By concentrating on the field of option pricing, a core task of financial engineering and risk analysis, this book explores a wide range of computational tools in a coherent and focused manner and will be of use to anyone working in computational finance. Starting with an introductory chapter that presents the financial and stochastic background, the book goes on to detail computational methods using both stochastic and deterministic approaches. Now in its sixth edition, Tools for Computational Finance has been significantly revised and contains:    Several new parts such as a section on extended applications of tree methods, including multidimensional trees, trinomial trees, and the handling of dividends; Additional material in the field of generating normal variates with acceptance-rejection methods, and on Monte Carlo methods...

  6. SIRTF Tools for DIRT

    Science.gov (United States)

    Pound, M. W.; Wolfire, M. G.; Amarnath, N. S.

    2004-07-01

    The Dust InfraRed ToolBox (DIRT - a part of the Web Infrared ToolShed, or WITS {http://dustem.astro.umd.edu}) is a Java applet for modeling astrophysical processes in circumstellar shells around young and evolved stars. DIRT has been used by the astrophysics community for about 5 years. Users can automatically and efficiently search grids of pre-calculated models to fit their data. A large set of physical parameters and dust types are included in the model database, which contains over 500,000 models. We are adding new functionality to DIRT to support new missions like SIRTF and SOFIA. A new Instrument module allows for plotting of the model points convolved with the spatial and spectral responses of the selected instrument. This lets users better fit data from specific instruments. Currently, we have implemented modules for the Infrared Array Camera (IRAC) and Multiband Imaging Photometer (MIPS) on SIRTF. The models are based on the dust radiation transfer code of Wolfire & Cassinelli (1986) which accounts for multiple grain sizes and compositions. The model outputs are averaged over the instrument bands using the same weighting (νFν = constant) as the SIRTF data pipeline which allows the SIRTF data products to be compared directly with the model database. This work was supported in part by a NASA AISRP grant NAG 5-10751 and the SIRTF Legacy Science Program provided by NASA through an award issued by JPL under NASA contract 1407.

  7. Tools & Resources | Efficient Windows Collaborative

    Science.gov (United States)

    Foundry Foundry New Construction Windows Window Selection Tool Selection Process Design Guidance Installation Replacement Windows Window Selection Tool Assessing Options Selection Process Design Guidance Installation Understanding Windows Benefits Design Considerations Measuring Performance Performance Standards

  8. Soomlase disainitud tool sai preemia

    Index Scriptorium Estoniae

    2005-01-01

    Isku OY disaineri Tapio Anttila loodud tool Haiku sai rahvusvahelisel disainikonkursil ADEX 2004 mööbli kategoorias Adex Silveri preemia. Mullu sai sama tool Chicago arhitektuuri- ja disainimuuseumi preemia Good Design Award

  9. Case and Administrative Support Tools

    Data.gov (United States)

    U.S. Environmental Protection Agency — Case and Administrative Support Tools (CAST) is the secure portion of the Office of General Counsel (OGC) Dashboard business process automation tool used to help...

  10. Criticism on Environmental Assessment Tools

    NARCIS (Netherlands)

    Abdalla, G.; Maas, G.J.; Huyghe, J.; Oostra, M.; Saji Baby, xx; Bogdan Zygmunt, xx

    2011-01-01

    Using environmental assessment tools to assess the sustainability of buildings, homes and mixed- use area is increasing. Environmental tools assign scores to projects using some sustainability (sub) aspects according to design and realization documents and evidences. Six European sustainable urban

  11. Transformational Tools and Technologies Project

    Data.gov (United States)

    National Aeronautics and Space Administration — The Transformational Tools and Technologies (TTT) Project advances state-of-the-art computational and experimental tools and technologies that are vital to aviation...

  12. Aperture Photometry Tool

    Science.gov (United States)

    Laher, Russ R.; Gorjian, Varoujan; Rebull, Luisa M.; Masci, Frank J.; Fowler, John W.; Helou, George; Kulkarni, Shrinivas R.; Law, Nicholas M.

    2012-07-01

    Aperture Photometry Tool (APT) is software for astronomers and students interested in manually exploring the photometric qualities of astronomical images. It is a graphical user interface (GUI) designed to allow the image data associated with aperture photometry calculations for point and extended sources to be visualized and, therefore, more effectively analyzed. The finely tuned layout of the GUI, along with judicious use of color-coding and alerting, is intended to give maximal user utility and convenience. Simply mouse-clicking on a source in the displayed image will instantly draw a circular or elliptical aperture and sky annulus around the source and will compute the source intensity and its uncertainty, along with several commonly used measures of the local sky background and its variability. The results are displayed and can be optionally saved to an aperture-photometry-table file and plotted on graphs in various ways using functions available in the software. APT is geared toward processing sources in a small number of images and is not suitable for bulk processing a large number of images, unlike other aperture photometry packages (e.g., SExtractor). However, APT does have a convenient source-list tool that enables calculations for a large number of detections in a given image. The source-list tool can be run either in automatic mode to generate an aperture photometry table quickly or in manual mode to permit inspection and adjustment of the calculation for each individual detection. APT displays a variety of useful graphs with just the push of a button, including image histogram, x and y aperture slices, source scatter plot, sky scatter plot, sky histogram, radial profile, curve of growth, and aperture-photometry-table scatter plots and histograms. APT has many functions for customizing the calculations, including outlier rejection, pixel “picking” and “zapping,” and a selection of source and sky models. The radial-profile-interpolation source

  13. Security for ICT collaboration tools

    NARCIS (Netherlands)

    Broenink, E.G.; Kleinhuis, G.; Fransen, F.

    2010-01-01

    In order for collaboration tools to be productive in an operational setting, an information base that is shared across the collaborating parties is needed. Therefore, a lot of research is done for tooling to create such a common information base in a collaboration tool. However, security is often

  14. Security for ICT collaboration tools

    NARCIS (Netherlands)

    Broenink, E.G.; Kleinhuis, G.; Fransen, F.

    2011-01-01

    In order for collaboration tools to be productive in an operational setting, an information base that is shared across the collaborating parties is needed. Therefore, a lot of research is done for tooling to create such a common information base in a collaboration tool. However, security is often

  15. Climate Action Planning Tool | NREL

    Science.gov (United States)

    NREL's Climate Action Planning Tool provides a quick, basic estimate of how various technology options can contribute to an overall climate action plan for your research campus. Use the tool to Tool Calculation Formulas and Assumptions Climate Neutral Research Campuses Website Climate Neutral

  16. Mathematical tools for physicists

    International Nuclear Information System (INIS)

    Trigg, G.L.

    2005-01-01

    Mathematical Tools for Physisists is a unique collection of 18 review articles, each one written by a renowned expert of its field. Their professional style will be beneficial for advanced students as well as for the scientist at work. The first may find a comprehensive introduction while the latter use it as a quick reference. Great attention was paid to ensuring fast access to the information, and each carefully reviewed article includes a glossary of terms and a guide to further reading. The contributions range from fundamental methods right up to the latest applications, including: - Algebraic Methods - Analytic Methods - Fourier and Other Mathematical Transforms - Fractal Geometry - Geometrical Methods - Green's Functions - Group Theory - Mathematical Modeling - Monte Carlo Methods - Numerical Methods - Perturbation Methods - Quantum Computation - Quantum Logic - Special Functions - Stochastic Processes - Symmetries and Conservation Laws - Topology - Variational Methods. (orig.)

  17. Remediating a design tool

    DEFF Research Database (Denmark)

    Jensen, Mads Møller; Rädle, Roman; Klokmose, Clemens N.

    2018-01-01

    digital sticky notes setup. The paper contributes with a nuanced understanding of what happens when remediating a physical design tool into digital space, by emphasizing focus shifts and breakdowns caused by the technology, but also benefits and promises inherent in the digital media. Despite users......' preference for creating physical notes, handling digital notes on boards was easier and the potential of proper documentation make the digital setup a possible alternative. While the analogy in our remediation supported a transfer of learned handling, the users' experiences across technological setups impact......Sticky notes are ubiquitous in design processes because of their tangibility and ease of use. Yet, they have well-known limitations in professional design processes, as documentation and distribution are cumbersome at best. This paper compares the use of sticky notes in ideation with a remediated...

  18. Digital Tectonic Tools

    DEFF Research Database (Denmark)

    Schmidt, Anne Marie Due

    2005-01-01

    Tectonics has been an inherent part of the architectural field since the Greek temples while the digital media is new to the field. This paper is built on the assumption that in the intermediate zone between the two there is a lot to be learned about architecture in general and the digital media...... in particular. A model of the aspects in the term tectonics – epresentation, ontology and culture – will be presented and used to discuss the current digital tools’ ability in tectonics. Furthermore it will be discussed what a digital tectonic tool is and could be and how a connection between the digital...... and tectonic could become a part of the architectural education....

  19. Tools for Social Construction

    DEFF Research Database (Denmark)

    Brynskov, Martin

    for social construction, i.e. supporting staging, performing, and sharing of playful activities involving people and artifacts.             The method used is a triangulation of the problem domain—pervasive media systems for children—from three perspectives: theory, design, and empirical work......: the potential of pervasive media systems to support the children’s social construction.  ......In this dissertation, I propose a new type of playful media for children. Based on field work, prototypes, and theoretical development, I define, build, and explore a distinct cross-section of existing and new digital media, tools, and communication devices in order to assess the characteristics...

  20. Tools for Understanding Identity

    Energy Technology Data Exchange (ETDEWEB)

    Creese, Sadie; Gibson-Robinson, Thomas; Goldsmith, Michael; Hodges, Duncan; Kim, Dee DH; Love, Oriana J.; Nurse, Jason R.; Pike, William A.; Scholtz, Jean

    2013-12-28

    Identity attribution and enrichment is critical to many aspects of law-enforcement and intelligence gathering; this identity typically spans a number of domains in the natural-world such as biographic information (factual information – e.g. names, addresses), biometric information (e.g. fingerprints) and psychological information. In addition to these natural-world projections of identity, identity elements are projected in the cyber-world. Conversely, undesirable elements may use similar techniques to target individuals for spear-phishing attacks (or worse), and potential targets or their organizations may want to determine how to minimize the attack surface exposed. Our research has been exploring the construction of a mathematical model for identity that supports such holistic identities. The model captures the ways in which an identity is constructed through a combination of data elements (e.g. a username on a forum, an address, a telephone number). Some of these elements may allow new characteristics to be inferred, hence enriching the holistic view of the identity. An example use-case would be the inference of real names from usernames, the ‘path’ created by inferring new elements of identity is highlighted in the ‘critical information’ panel. Individual attribution exercises can be understood as paths through a number of elements. Intuitively the entire realizable ‘capability’ can be modeled as a directed graph, where the elements are nodes and the inferences are represented by links connecting one or more antecedents with a conclusion. The model can be operationalized with two levels of tool support described in this paper, the first is a working prototype, the second is expected to reach prototype by July 2013: Understanding the Model The tool allows a user to easily determine, given a particular set of inferences and attributes, which elements or inferences are of most value to an investigator (or an attacker). The tool is also able to take

  1. Grid sleeve bulge tool

    International Nuclear Information System (INIS)

    Phillips, W.D.; Vaill, R.E.

    1980-01-01

    An improved grid sleeve bulge tool is designed for securing control rod guide tubes to sleeves brazed in a fuel assembly grid. The tool includes a cylinder having an outer diameter less than the internal diameter of the control rod guide tubes. The walls of the cylinder are cut in an axial direction along its length to provide several flexible tines or ligaments. These tines are similar to a fork except they are spaced in a circumferential direction. The end of each alternate tine is equipped with a semispherical projection which extends radially outwardly from the tine surface. A ram or plunger of generally cylindrical configuration and about the same length as the cylinder is designed to fit in and move axially of the cylinder and thereby force the tined projections outwardly when the ram is pulled into the cylinder. The ram surface includes axially extending grooves and plane surfaces which are complimentary to the inner surfaces formed on the tines on the cylinder. As the cylinder is inserted into a control rod guide tube, and the projections on the cylinder placed in a position just below or above a grid strap, the ram is pulled into the cylinder, thus moving the tines and the projections thereon outwardly into contact with the sleeve, to plastically deform both the sleeve and the control rod guide tube, and thereby form four bulges which extend outwardly from the sleeve surface and beyond the outer periphery of the grid peripheral strap. This process is then repeated at the points above the grid to also provide for outwardly projecting surfaces, the result being that the grid is accurately positioned on and mechanically secured to the control rod guide tubes which extend the length of a fuel assembly

  2. PRACTICAL APPLICATION OF QUALITY TOOLS

    Directory of Open Access Journals (Sweden)

    Duško Pavletić

    2008-09-01

    Full Text Available The paper is dealing with one segment of broader research of universality an systematicness in application of seven basic quality tools (7QC tools, which is possible to use in different areas: power plant, process industry, government, health and tourism services. The aim of the paper was to show on practical examples that there is real possibility of application of 7QC tools. Furthermore, the research has to show to what extent are selected tools in usage and what reasons of avoiding their broader application are. The simple example of successful application of the quality tools are shown on selected company in process industry.

  3. Tool for treating subterranean wells

    International Nuclear Information System (INIS)

    Muller, L.; Randermann, E.

    1991-01-01

    This paper describes a system for treating subterranean wells. It comprises: elongated treatment tool having inflatable packers, a support tube connected to one end of the tool operable to lower tool from a well head into a well and to supply liquid to tool, the tool providing valve means operable in response changes in tension ins aid tube and without rotating the tube sequentially: (a) inflate the packers to isolate one portion of the from the remaining portions thereof and to lock the against movement along the well; (b) inject treatment fluid supplied to the tool through support tube into the one portion of the well and (c) deflate the packers permitting further movement of tool along the well

  4. Materials selection for cutting tools

    International Nuclear Information System (INIS)

    Burkhis, Adel M.

    2008-01-01

    The selection of proper tool steel for a given application is a difficult task. So; the most important selection factors in choosing cutting tool materials are based on their tool material requirements, cutting tool design and service conditions which is mainly considered as functional requirements. The processability requirements concerns in heat treat ability of the material tool. The classification of these tool materials were discussed with their properties requirement and percent of alloying element which is added to give best properties with a little increase in cost that highly appear in comparison of the selection. The cutting tool materials were evaluated based on two cases; The first was in case of rough surface; the high speed steels is the best material and the other was the ceramic material is the highest performance in cutting of soft or high rate of metal removal. (author)

  5. Hurricane Data Analysis Tool

    Science.gov (United States)

    Liu, Zhong; Ostrenga, Dana; Leptoukh, Gregory

    2011-01-01

    In order to facilitate Earth science data access, the NASA Goddard Earth Sciences Data Information Services Center (GES DISC) has developed a web prototype, the Hurricane Data Analysis Tool (HDAT; URL: http://disc.gsfc.nasa.gov/HDAT), to allow users to conduct online visualization and analysis of several remote sensing and model datasets for educational activities and studies of tropical cyclones and other weather phenomena. With a web browser and few mouse clicks, users can have a full access to terabytes of data and generate 2-D or time-series plots and animation without downloading any software and data. HDAT includes data from the NASA Tropical Rainfall Measuring Mission (TRMM), the NASA Quick Scatterometer(QuikSCAT) and NECP Reanalysis, and the NCEP/CPC half-hourly, 4-km Global (60 N - 60 S) IR Dataset. The GES DISC archives TRMM data. The daily global rainfall product derived from the 3-hourly multi-satellite precipitation product (3B42 V6) is available in HDAT. The TRMM Microwave Imager (TMI) sea surface temperature from the Remote Sensing Systems is in HDAT as well. The NASA QuikSCAT ocean surface wind and the NCEP Reanalysis provide ocean surface and atmospheric conditions, respectively. The global merged IR product, also known as, the NCEP/CPC half-hourly, 4-km Global (60 N -60 S) IR Dataset, is one of TRMM ancillary datasets. They are globally-merged pixel-resolution IR brightness temperature data (equivalent blackbody temperatures), merged from all available geostationary satellites (GOES-8/10, METEOSAT-7/5 & GMS). The GES DISC has collected over 10 years of the data beginning from February of 2000. This high temporal resolution (every 30 minutes) dataset not only provides additional background information to TRMM and other satellite missions, but also allows observing a wide range of meteorological phenomena from space, such as, hurricanes, typhoons, tropical cyclones, mesoscale convection system, etc. Basic functions include selection of area of

  6. REPLICATION TOOL AND METHOD OF PROVIDING A REPLICATION TOOL

    DEFF Research Database (Denmark)

    2016-01-01

    The invention relates to a replication tool (1, 1a, 1b) for producing a part (4) with a microscale textured replica surface (5a, 5b, 5c, 5d). The replication tool (1, 1a, 1b) comprises a tool surface (2a, 2b) defining a general shape of the item. The tool surface (2a, 2b) comprises a microscale...... energy directors on flange portions thereof uses the replication tool (1, 1a, 1b) to form an item (4) with a general shape as defined by the tool surface (2a, 2b). The formed item (4) comprises a microscale textured replica surface (5a, 5b, 5c, 5d) with a lateral arrangement of polydisperse microscale...

  7. Draper Station Analysis Tool

    Science.gov (United States)

    Bedrossian, Nazareth; Jang, Jiann-Woei; McCants, Edward; Omohundro, Zachary; Ring, Tom; Templeton, Jeremy; Zoss, Jeremy; Wallace, Jonathan; Ziegler, Philip

    2011-01-01

    Draper Station Analysis Tool (DSAT) is a computer program, built on commercially available software, for simulating and analyzing complex dynamic systems. Heretofore used in designing and verifying guidance, navigation, and control systems of the International Space Station, DSAT has a modular architecture that lends itself to modification for application to spacecraft or terrestrial systems. DSAT consists of user-interface, data-structures, simulation-generation, analysis, plotting, documentation, and help components. DSAT automates the construction of simulations and the process of analysis. DSAT provides a graphical user interface (GUI), plus a Web-enabled interface, similar to the GUI, that enables a remotely located user to gain access to the full capabilities of DSAT via the Internet and Webbrowser software. Data structures are used to define the GUI, the Web-enabled interface, simulations, and analyses. Three data structures define the type of analysis to be performed: closed-loop simulation, frequency response, and/or stability margins. DSAT can be executed on almost any workstation, desktop, or laptop computer. DSAT provides better than an order of magnitude improvement in cost, schedule, and risk assessment for simulation based design and verification of complex dynamic systems.

  8. Java Radar Analysis Tool

    Science.gov (United States)

    Zaczek, Mariusz P.

    2005-01-01

    Java Radar Analysis Tool (JRAT) is a computer program for analyzing two-dimensional (2D) scatter plots derived from radar returns showing pieces of the disintegrating Space Shuttle Columbia. JRAT can also be applied to similar plots representing radar returns showing aviation accidents, and to scatter plots in general. The 2D scatter plots include overhead map views and side altitude views. The superposition of points in these views makes searching difficult. JRAT enables three-dimensional (3D) viewing: by use of a mouse and keyboard, the user can rotate to any desired viewing angle. The 3D view can include overlaid trajectories and search footprints to enhance situational awareness in searching for pieces. JRAT also enables playback: time-tagged radar-return data can be displayed in time order and an animated 3D model can be moved through the scene to show the locations of the Columbia (or other vehicle) at the times of the corresponding radar events. The combination of overlays and playback enables the user to correlate a radar return with a position of the vehicle to determine whether the return is valid. JRAT can optionally filter single radar returns, enabling the user to selectively hide or highlight a desired radar return.

  9. Discovery Mondays: Surveyors' Tools

    CERN Multimedia

    2003-01-01

    Surveyors of all ages, have your rulers and compasses at the ready! This sixth edition of Discovery Monday is your chance to learn about the surveyor's tools - the state of the art in measuring instruments - and see for yourself how they work. With their usual daunting precision, the members of CERN's Surveying Group have prepared some demonstrations and exercises for you to try. Find out the techniques for ensuring accelerator alignment and learn about high-tech metrology systems such as deviation indicators, tracking lasers and total stations. The surveyors will show you how they precisely measure magnet positioning, with accuracy of a few thousandths of a millimetre. You can try your hand at precision measurement using different types of sensor and a modern-day version of the Romans' bubble level, accurate to within a thousandth of a millimetre. You will learn that photogrammetry techniques can transform even a simple digital camera into a remarkable measuring instrument. Finally, you will have a chance t...

  10. PyForecastTools

    Energy Technology Data Exchange (ETDEWEB)

    2017-09-22

    The PyForecastTools package provides Python routines for calculating metrics for model validation, forecast verification and model comparison. For continuous predictands the package provides functions for calculating bias (mean error, mean percentage error, median log accuracy, symmetric signed bias), and for calculating accuracy (mean squared error, mean absolute error, mean absolute scaled error, normalized RMSE, median symmetric accuracy). Convenience routines to calculate the component parts (e.g. forecast error, scaled error) of each metric are also provided. To compare models the package provides: generic skill score; percent better. Robust measures of scale including median absolute deviation, robust standard deviation, robust coefficient of variation and the Sn estimator are all provided by the package. Finally, the package implements Python classes for NxN contingency tables. In the case of a multi-class prediction, accuracy and skill metrics such as proportion correct and the Heidke and Peirce skill scores are provided as object methods. The special case of a 2x2 contingency table inherits from the NxN class and provides many additional metrics for binary classification: probability of detection, probability of false detection, false alarm ration, threat score, equitable threat score, bias. Confidence intervals for many of these quantities can be calculated using either the Wald method or Agresti-Coull intervals.

  11. Range Process Simulation Tool

    Science.gov (United States)

    Phillips, Dave; Haas, William; Barth, Tim; Benjamin, Perakath; Graul, Michael; Bagatourova, Olga

    2005-01-01

    Range Process Simulation Tool (RPST) is a computer program that assists managers in rapidly predicting and quantitatively assessing the operational effects of proposed technological additions to, and/or upgrades of, complex facilities and engineering systems such as the Eastern Test Range. Originally designed for application to space transportation systems, RPST is also suitable for assessing effects of proposed changes in industrial facilities and large organizations. RPST follows a model-based approach that includes finite-capacity schedule analysis and discrete-event process simulation. A component-based, scalable, open architecture makes RPST easily and rapidly tailorable for diverse applications. Specific RPST functions include: (1) definition of analysis objectives and performance metrics; (2) selection of process templates from a processtemplate library; (3) configuration of process models for detailed simulation and schedule analysis; (4) design of operations- analysis experiments; (5) schedule and simulation-based process analysis; and (6) optimization of performance by use of genetic algorithms and simulated annealing. The main benefits afforded by RPST are provision of information that can be used to reduce costs of operation and maintenance, and the capability for affordable, accurate, and reliable prediction and exploration of the consequences of many alternative proposed decisions.

  12. Tool and Fixture Design

    Energy Technology Data Exchange (ETDEWEB)

    Graham, Mark W. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2015-07-28

    In a manufacturing process, a need is identified and a product is created to fill this need. While design and engineering of the final product is important, the tools and fixtures that aid in the creation of the final product are just as important, if not more so. Power supplies assembled at the TA-55 PF-5 have been designed by an excellent engineering team. The task in PF-5 now is to ensure that all steps of the assembly and manufacturing process can be completed safely, reliably, and in a quality repeatable manner. One of these process steps involves soldering fine wires to an electrical connector. During the process development phase, the method of soldering included placing the power supply in a vice in order to manipulate it into a position conducive to soldering. This method is unacceptable from a reliability, repeatability, and ergonomic standpoint. To combat these issues, a fixture was designed to replace the current method. To do so, a twelve step engineering design process was used to create the fixture that would provide a solution to a multitude of problems, and increase the safety and efficiency of production.

  13. Tools of radio astronomy

    CERN Document Server

    Wilson, Thomas L; Hüttemeister, Susanne

    2013-01-01

    This 6th edition of “Tools of Radio Astronomy”, the most used introductory text in radio astronomy, has been revised to reflect the current state of this important branch of astronomy. This includes the use of satellites, low radio frequencies, the millimeter/sub-mm universe, the Cosmic Microwave Background and the increased importance of mm/sub-mm dust emission. Several derivations and presentations of technical aspects of radio astronomy and receivers, such as receiver noise, the Hertz dipole and  beam forming have been updated, expanded, re-worked or complemented by alternative derivations. These reflect advances in technology. The wider bandwidths of the Jansky-VLA and long wave arrays such as LOFAR and mm/sub-mm arrays such as ALMA required an expansion of the discussion of interferometers and aperture synthesis. Developments in data reduction algorithms have been included. As a result of the large amount of data collected in the past 20 years, the discussion of solar system radio astronomy, dust em...

  14. Perception as a Tool

    Directory of Open Access Journals (Sweden)

    Jovana Komnenič

    2014-03-01

    Full Text Available The article presents a project of providing guidelines on art education for the blind and visually impaired, which was entitled Perception as a Tool and presented at the Berlin Biennale on 6 October 2010. It focuses on potential aspects of art education with regard to people with special needs and seeks to discover what happens with art if we cannot see it. This approach to art education combines elements of conventional tours of exhibitions and involves the participants through play. The methods that were used in our work included establishing dramatic tension and insecurity in the group as well as mutual trust by relying on different resources, including sensory perception, personal biography and different forms of knowledge and skills. A major part of the project is finding hidden, invisible or forgotten stories that are not directly linked to the exhibition and the aspects directly related to the exhibition. Such a generally inclusive approach enabled us to formulate political questions on the issue of ’invisibility’.

  15. Data summary report on short-term turbidity monitoring of pipeline river crossings in the Moyie River, Boundary County, Idaho: PGT-PG&E Pipeline Expansion Project

    Energy Technology Data Exchange (ETDEWEB)

    Gowdy, M.J.; Smits, M.P.; Wilkey, P.L.; Miller, S.F.

    1994-03-01

    A water-quality monitoring program was implemented for Bechtel Corporation to measure the short-term increases in turbidity in the Moyie River caused by construction activities of the Pacific Gas Transmission-Pacific Gas & Electric Pipeline Expansion Project. Construction of the buried, 42-in.-diameter, steel pipeline, during the summer of 1992, involved eight wet crossings of the Moyie River along the 13-mi section of pipeline immediately south of the Canadian-United States border in Boundary County, Idaho. This report summarizes the sampling and analysis protocol used and gives the results and observations for each of the eight crossings. The data obtained from this monitoring program, in addition to satisfying regulatory requirements for the Pipeline Expansion Project, will contribute to an ongoing long-term study of the Moyie River crossings being performed for the Gas Research Institute by Argonne National Laboratory. The purpose of this document is strictly limited to reporting the results of the monitoring program. Interpretation of the data is not within the scope of this report.

  16. Effect of adding the novel fiber, PGX®, to commonly consumed foods on glycemic response, glycemic index and GRIP: a simple and effective strategy for reducing post prandial blood glucose levels - a randomized, controlled trial

    Directory of Open Access Journals (Sweden)

    Lyon Michael

    2010-11-01

    Full Text Available Abstract Background Reductions in postprandial glycemia have been demonstrated previously with the addition of the novel viscous polysaccharide (NVP, PolyGlycopleX® (PGX®, to an OGTT or white bread. This study explores whether these reductions are sustained when NVP is added to a range of commonly consumed foods or incorporated into a breakfast cereal. Methods Ten healthy subjects (4M, 6F; age 37.3 ± 3.6 y; BMI 23.8 ± 1.3 kg/m2, participated in an acute, randomized controlled trial. The glycemic response to cornflakes, rice, yogurt, and a frozen dinner with and without 5 g of NVP sprinkled onto the food was determined. In addition, 3 granolas with different levels of NVP and 3 control white breads and one white bread and milk were also consumed. All meals contained 50 g of available carbohydrate. Capillary blood samples were taken fasting and at 15, 30, 45, 60, 90 and 120 min after the start of the meal. The glycemic index (GI and the glycemic reduction index potential (GRIP were calculated. The blood glucose concentrations at each time and the iAUC values were subjected to repeated-measures analysis of variance (ANOVA examining for the effect of test meal. After demonstration of significant heterogeneity, differences between individual means was assessed using GLM ANOVA with Tukey test to adjust for multiple comparisons. Results Addition of NVP reduced blood glucose response irrespective of food or dose (p Conclusion Sprinkling or incorporation of NVP into a variety of different foods is highly effective in reducing postprandial glycemia and lowering the GI of a food. Clinical Trial registration NCT00935350.

  17. Tools: Stuff: Art

    Directory of Open Access Journals (Sweden)

    David Kirshner

    2014-07-01

    Full Text Available Between 1890 and 1898 Erik Satie lived at 6 rue Cortot: ‘in a wardrobe’. Satie was a collector […]. After his death his wardrobe was found to contain 84 handkerchiefs besides 12 identical velvet suits and dozens of umbrellas. 
Trois morceaux en forme de poire […] three pieces in the form of a pear. The title of a piano piece in seven parts by Erik Satie. Satie composed this piece in response to Debussy's criticism that his works lacked a 'sense of form'. What exactly did Debussy mean by this? Where and what actually was this scene of formlessness? 
The first part of the Paper will advance some possible reasoning behind Debussy's comments. Was Debussy questioning Satie's attitude to what Heidegger [in The Origin of the Work of Art] would term the 'thingly' element of the Work of Art, or more precisely – the relationship between 'things' and the 'thing in itself'?
Heidegger's contemplation of 'Form' and his writings on 'tools', 'material' and 'art', and the section dealing with the Temple provides an interesting locus in which to discus Debussy's comments.
The second section gives some ideas of how I reinterpreted this argument to produce a series of visual works inspired by another of Satie's works, Furniture Music – Musique d' ameublement, a piece of music that was not to be listened to. 
Milhaud later recounted: ‘It was no use Satie shouting: “Talk for heaven's sake! Move around! Don't listen!” They kept quiet. They listened. The whole thing went wrong.’

  18. Blog: occupational therapy tool

    Directory of Open Access Journals (Sweden)

    Miryam Bonadiu Pelosi

    2012-12-01

    Full Text Available A blog is a site whose structure allows fast articles postage update, or posts. In a blog, texts, images, videosand links to other blogs can be combined, and what makes it a potential therapeutic working tool are the users’ friendlyresources provided for creating and editing systems, which do not require complex knowledge of programmingresources. As in any activity, the professional needs to know it well before being able to use it as a therapeutic resource,but this one is free of charge and it can be performed in gradual steps at different complexity levels. A blog can beused as an idea-organizer, a site where the user decides what is pertinent to be posted, which vocabulary to be used,and the target public, as in a space to share experiences or an integral part in the elaboration of a history book. Tosupport this discussion, three cases where blogs were used as therapeutic resources were presented. In the first case, a12-year-old boy diagnosed with Asperger’s Syndrome created a blog about children characters; on the second, a groupof adolescents with school and social inclusion difficulties developed a blog to tell their adventures; finally, the thirdcase told the story of a girl with cerebral palsy who wrote and published a book and a blog with the help of alternativecommunication strategies. The following themes were addressed as topics for the discussion: activity as therapeuticresource; the different uses of blogs in the worldwide computers net; and the possibility of using blogs as occupationaltherapeutic resources for people with singular life histories, with very diverse abilities, limitations and desires.

  19. Simple Functions Spreadsheet tool presentation

    International Nuclear Information System (INIS)

    Grive, Mireia; Domenech, Cristina; Montoya, Vanessa; Garcia, David; Duro, Lara

    2010-09-01

    This document is a guide for users of the Simple Functions Spreadsheet tool. The Simple Functions Spreadsheet tool has been developed by Amphos 21 to determine the solubility limits of some radionuclides and it has been especially designed for Performance Assessment exercises. The development of this tool has been promoted by the necessity expressed by SKB of having a confident and easy-to-handle tool to calculate solubility limits in an agile and relatively fast manner. Its development started in 2005 and since then, it has been improved until the current version. This document describes the accurate and preliminary study following expert criteria that has been used to select the simplified aqueous speciation and solid phase system included in the tool. This report also gives the basic instructions to use this tool and to interpret its results. Finally, this document also reports the different validation tests and sensitivity analyses that have been done during the verification process

  20. Design of tool monitor simulator

    International Nuclear Information System (INIS)

    Yao Yonggang; Deng Changming; Zhang Jia; Meng Dan; Zhang Lu; Wang Zhi'ai; Shen Yang

    2011-01-01

    It is based on tool monitor in Qinshan Nuclear Power Plant for the object of study, and manufacture a tool monitor simulator. The device is designed to automatically emulate-monitor the contamination level of objects for training students. Once if the tool monitor reports the contamination, the students can handle properly. The brief introduction of main function and system design of the simulator are presented in the paper. (authors)