WorldWideScience

Sample records for grip strength bent

  1. Hand grip strength

    DEFF Research Database (Denmark)

    Frederiksen, Henrik; Gaist, David; Petersen, Hans Christian

    2002-01-01

    in life is a major problem in terms of prevalence, morbidity, functional limitations, and quality of life. It is therefore of interest to find a phenotype reflecting physical functioning which has a relatively high heritability and which can be measured in large samples. Hand grip strength is known......-55%). A powerful design to detect genes associated with a phenotype is obtained using the extreme discordant and concordant sib pairs, of whom 28 and 77 dizygotic twin pairs, respectively, were found in this study. Hence grip strength is a suitable phenotype for identifying genetic variants of importance to mid...

  2. Examinations of factors influencing toe grip strength.

    Science.gov (United States)

    Soma, Masayuki; Murata, Shin; Kai, Yoshihiro; Nakae, Hideyuki; Satou, Yousuke; Murata, Jun; Miyazaki, Junya

    2016-11-01

    [Purpose] This study examined the relationship between toe grip strength and its associated factors by focusing on factors that were suggested to have a relationship with toe grip strength in previous studies, aiming to clarify the factors influencing the toe grip strength of healthy women. [Subjects and Methods] Twelve healthy young women were selected for this study. Their toe grip strength, angular changes in their ankle joint during toe grip, maximum voluntary contraction activities of the rectus femoris, biceps femoris, and tibialis anterior muscles, and the medial head of the gastrocnemius muscles were measured using electromyography. Their toe curl ability, foot-arch height ratio, and weight were also measured. [Results] Multiple regression analysis demonstrated that the predictors of toe grip strength in the resulting model were foot-arch height ratio and the percentage of integrated electromyography (%IEMG) of the tibialis anterior muscle, as the dependent variables. This reveals that women whose tibialis anterior muscle %IEMG values and foot-arch height ratio are high have greater %IEMG values have greater toe grip strength. [Conclusion] These findings suggest a significant relationship between foot-arch height ratio and toe grip strength, with a reciprocal interaction. These findings further indicate that the risk of falls by the elderly could be decreased if toe grip strength were enhanced, by increasing the height of a low foot-arch with the help of an inserted insole.

  3. [Grip strength changes in familial amyloidotic polyneuropathy].

    Science.gov (United States)

    Tomás, Maria Teresa; Santa-Clara, Helena; Monteiro, Estela; Carolino, Elizabete; Freire, António; Barroso, Eduardo

    2010-01-01

    Familial amiloidotic polyneuropathy (FAP) is an autossomical and dominant neurodegenerative disease related with systemic deposition of amyloid fibre mainly on peripheral nervous system. Clinically, is translated by an autonomous sensitive-motor polyneuropathy with beginning nearly always in foot, involving subsequently the hands. Until now, the unique available treatment for FAP disease is liver transplantation requiring medication that negatively affect muscle metabolism and force production mechanism. To our knowledge there are no quantitative characterizations of peak force in FAP patients or any comparison with healthy people. This knowledge will be extremely important to verify clinical and functional evolution of this disease and eventually prescribe an effective rehabilitation program. The purpose of this study was to analyse and compare levels of hand grip strength (peak force and endurance) in FAP patients with (FAPTx) or without (FAPNTx) a liver transplant with a group of healthy people (GC). The total sample of individuals where two hundred and six, assigned in 3 groups: 59 patients PAFNTx (23 males, 36 female; age 35 ± 8 years); 90 patients PAFTx (53 males, 37 females; age 34 ± 8 years) e 62 healthy persons (GC) (30 males, 32 females; age 33 ± 9 years). Grip strength was assessed by a portable grip dynamometer E-link (Biometrics Ltd, UK). All measurements were taken on standardized positions with standardized orders. The value noted to peak force was classified according to American College of Sports Medicine norms for grip strength. The 3 groups are differents (p < 0,05) for weigth, body mass index (BMI) and grip strength in both hands and endurance for left hand. Negative correlations between age and grip strength were found for PAFNTx and PAFTx but not for GC. According to our results FAP patients have lower values for grip strength in both hands than healthy subjects and consequently a worse classification in ACSM norms. Most patients present

  4. Hand-grip isometric strength in judo

    Directory of Open Access Journals (Sweden)

    Juan G Bonitch-Góngora

    2014-02-01

    Full Text Available The grip is an important technical and tactical aspect through which the judokas dominate the adversary, hindering the application of appropriate techniques and favoring their own attack. The judokas must have high levels of isometric force and endurance to this type of force on the gripping muscles of the forearms, as one of the key aspects for success. This article reviews the grip muscular strength and endurance profiles of judokas of different groups (gender, age and competitive level. In general, the peak isometric strength of elite judokas has not changed in the last 40 years and is similar to that reached by non-elite judokas or even registered in large populations. This indicate that the evaluation of the isometric hand grip endurance may be a more relevant parameter than the peak isometric force in judokas, as during the bouts the grip must be maintained for relatively long periods of time and the maximum force cannot be maintained for long. However there are few studies on the ability to resist successive isometric handgrip stress in judokas.

  5. Normative data on functional grip strength of elderly in Singapore.

    Science.gov (United States)

    Mat Jais, Ita Suzana; Chan, Kai Li; Loke, Mun Kitt Austin; Abdul Rahim, Saleem; Tay, Shian Chao

    2017-02-21

    Cross-sectional study for clinical measurement. Most daily tasks require individuals to exert grip strength with torque, which can be challenging for elderly as their strength diminishes with age. We postulate that to assess the functional capacity of an individual, it is important to evaluate the functional grip strength instead of the maximal static grip strength. The objective of this cross-sectional study is to establish normative data for the functional grip strength of elderly aged 60 years and older in the Singapore population. In this study, 233 healthy subjects aged 60 years and older were recruited. Using a custom-made hand strength measurement device, the following measurements were recorded: grip strength at neutral position, grip strength with resistive pronation torque, and grip strength with resistive supination torque. Grip strengths measured for both genders decreased by 13% and 16% for males and females respectively, when pronation torque was exerted, and with supination torque, the strength decreased by 18% and 17% for males and females respectively. Normative data for the elderly population in Singapore had been established. The findings from this study can complement the existing ergonomic hand data in designing better assistive tools to improve the independent living of elderly. NA. Copyright © 2016 Hanley & Belfus. Published by Elsevier Inc. All rights reserved.

  6. Association of grip strength with cardiovascular risk markers.

    Science.gov (United States)

    Gubelmann, Cédric; Vollenweider, Peter; Marques-Vidal, Pedro

    2017-03-01

    Background Mechanisms underlying the association between grip strength and cardiovascular mortality are poorly understood. We aimed to assess the association of grip strength with a panel of cardiovascular risk markers. Design The study was based on a cross-sectional analysis of 3468 adults aged 50-75 years (1891 women) from a population-based sample in Lausanne, Switzerland. Methods Grip strength was measured using a hydraulic hand dynamometer. Cardiovascular risk markers included anthropometry, blood pressure, lipids, glucose, adiposity, inflammatory and other metabolic markers. Results In both genders, grip strength was negatively associated with fat mass (Pearson correlation coefficient: women: -0.170, men: -0.198), systolic blood pressure (women: -0.096, men: -0.074), fasting glucose (women: -0.048, men: -0.071), log-transformed leptin (women: -0.074, men: -0.065), log-transformed high-sensitivity C-reactive protein (women: -0.101, men: -0.079) and log-transformed homocysteine (women: -0.109, men: -0.060). In men, grip strength was also positively associated with diastolic blood pressure (0.068), total (0.106) and low density lipoprotein-cholesterol (0.082), and negatively associated with interleukin-6 (-0.071); in women, grip strength was negatively associated with triglycerides (-0.064) and uric acid (-0.059). After multivariate adjustment, grip strength was negatively associated with waist circumference (change per 5 kg increase in grip strength: -0.82 cm in women and -0.77 cm in men), fat mass (-0.56% in women; -0.27% in men) and high-sensitivity C-reactive protein (-6.8% in women; -3.2% in men) in both genders, and with body mass index (0.22 kg/m(2)) and leptin (-2.7%) in men. Conclusion Grip strength shows only moderate associations with cardiovascular risk markers. The effect of muscle strength as measured by grip strength on cardiovascular disease does not seem to be mediated by cardiovascular risk markers.

  7. G×E Interaction Influences Trajectories of Hand Grip Strength

    DEFF Research Database (Denmark)

    Petersen, Inge; Pedersen, Nancy L; Rantanen, Taina;

    2016-01-01

    and Environment across Multiple Studies consortium. Growth curve parameters were estimated for same-sex pairs, aged 34-99 (N = 10,681). Fisher's test for mixture distribution of within-monozygotic twin-pair differences (N = 1724) was performed on growth curve parameters. We observed significant gene......-environment interaction on grip strength trajectories. Finally, we compared the variability of within-pair differences of growth curve parameters by APOE haplotypes. Though not statistically significant, the results suggested that APOE ɛ2ɛ2/ɛ2ɛ3 haplotypes might buffer environmental influences on grip strength...

  8. Grip and Pinch Strength Norms for Michigan Workers

    Directory of Open Access Journals (Sweden)

    Joel M. Phillips M.S., OTRL

    2013-06-01

    Full Text Available The purpose of this study was to create a norm reference of current grip and pinch strength norms for working-age Michigan adults. This normative study included a convenience sample of 179 volunteers who were employees at car plants in South East Michigan or hospital sites in West Michigan. Participants’ ages ranged from between 20 and 62 years of age with a mean age of 49.15 years. There were 78 females (44% and 101 males (56%. Subjects were classified by gender and in the age categories of ages 20 to 49 years and ages 50-62 years. Grip and pinch strength norms were collected following the American Society of Hand Therapy protocol. The norms from these working adults were calculated with descriptive statistics for males and females in two age classifications: ages 20 to 49 and ages 50 to 62 years. Standard Errors (SE are better than the 1985 norms for both males and females ages 20 to 49 years. SEs are higher than the ages 20 to 49 years’ norms for the ages 50 to 62 years age categories in both males and females. These norms offer a point of comparison for clinicians to use for clients in Michigan who are ages 20 to 62 years and who have a goal to improve their grip strength. Clients’ grip and pinch strength could be compared to their age level or gender norms using the comparison for one standard deviation above, below, or at the means.

  9. Hand Grip Strength Vs. Sprint Effectiveness in Amputee Soccer Players

    Directory of Open Access Journals (Sweden)

    Wieczorek Marta

    2015-12-01

    Full Text Available Amputee soccer is one of the types of soccer designed for the disabled, especially those who have undergone amputations, as well as those with extremity dysfunction. The objective of the study was to find the relationship between hand grip strength and sprint time in amputee soccer players. Thirteen field amputee soccer players participated in the study. A SAEHAN hydraulic hand dynamometer manufactured by Jamar was used for hand grip strength measurements. The sprint running test was conducted over a distance of 30 m. The Fusion Smart Speed System was employed for running time measurements. No statistically significant relationships were found between hand grip strength of the left or right hand, and sprint times over 1, 5, 10, 15, 20, 25 and 30 m. Analysis of the running velocity curve of the subjects showed an interesting profile characterized by a 15 meter-long acceleration phase and a significant velocity increase over a distance of 20 – 25 m. The study suggests that there is no relationship between hand grip strength and sprint effectiveness in amputee soccer players. The specificity of locomotion with the use of elbow crutches among elite Polish amputee soccer players probably accounts for the profile of the sprint velocity curve. Extension of the acceleration phase in the sprint run and a velocity increase in the subsequent part of the run were observed.

  10. Effects of hyperthyroidism on hand grip strength and function.

    Science.gov (United States)

    Erkol İnal, Esra; Çarlı, Alparslan Bayram; Çanak, Sultan; Aksu, Oğuzhan; Köroğlu, Banu Kale; Savaş, Serpil

    2015-01-01

    Hyperthyroidism is a pathologic condition in which the body is exposed to excessive amounts of circulating thyroid hormones. Skeletal muscle is one of the major target organs of thyroid hormones. We evaluated hand grip strength and function in patients with overt hyperthyroidism. Fifty-one patients newly diagnosed with hyperthyroidism and 44 healthy controls participated in this study. Age, height, weight, and dominant hand of all participants were recorded. The diagnosis of hyperthyroidism was confirmed by clinical examination and laboratory tests. Hand grip strength was tested at the dominant hand with a Jamar hand dynamometer. The grooved pegboard test (PGT) was used to evaluate hand dexterity. The Duruöz Hand Index (DHI) was used to assess hand function. No significant differences were found in terms of clinical and demographic findings between the patients with hyperthyroidism and healthy controls (p > 0.05). Significant differences were found between the patients with hyperthyroidism and healthy controls regarding PGT and DHI scores (p Hyperthyroidism seemed to affect hand dexterity and function more than hand grip strength and seemed to be associated with reduced physical function more than muscle strength. This may also indicate that patients with hyperthyroidism should be evaluated by multidisplinary modalities.

  11. Grip strength in healthy caucasian adults: reference values.

    Science.gov (United States)

    Günther, Christian M; Bürger, Alexander; Rickert, Markus; Crispin, Alexander; Schulz, Christoph U

    2008-04-01

    The aim of this study was to update reference data of handgrip strength for healthy adults of both genders spanning a wide age range and to analyze possible factors of influence. Intraindividual and interindividual variations of grip strength and their relation to several anthropometric factors were analyzed in a standardized manner for 769 healthy adults (women, n = 403; men, n = 366) aged between 20 years and 95 years. Measurements were done in neutral position of arm, forearm, and wrist on setting II of a Baseline digital hydraulic dynamometer (NexGen Ergonomics Inc. Quebec, Canada). Mean strength was about 41% less in women (right 29 kg; left 27 kg) than in men (right 49 kg; left 47 kg) resulting in a ratio of left to right hand slightly above .95 in both genders. During the course of life, hand strength develops comparably in both genders peaking at 35 years of age and decreasing continuously further on. Anthropometric variables such as forearm circumference and length, hand size, or body mass showed a positive correlation with grip strength. Body mass index, type of work, and hand dominance showed only a partial positive correlation or no correlation with grip strength. Gender and age, followed by parameters representing body length and obesity, were observed to have the highest predictive value for handgrip strength and were therefore entered into the generation of prediction equations. We recommend side adjustment of measured values for intraindividual comparison and inclusion of information regarding anthropometric characteristics, as well as using gender- and age-adjusted reference values, whereas hand dominance can be neglected. The regression equations we generated might prove to be useful for clinicians or for those who use normative values within software to provide more accurate predictions of strength scores for specific applications.

  12. Comparative study of maximum isometric grip strength in different sports

    Directory of Open Access Journals (Sweden)

    Noé Gomes Borges Junior

    2009-06-01

    Full Text Available The objective of this study was to compare maximum isometric grip strength (Fmaxbetween different sports and between the dominant (FmaxD and non-dominant (FmaxND hand. Twenty-nine male aikido (AI, jiujitsu (JJ, judo (JU and rowing (RO athletes and 21non-athletes (NA participated in the study. The hand strength test consisted of maintainingmaximum isometric grip strength for 10 seconds using a hand dynamometer. The position of the subjects was that suggested by the American Society of Hand Therapy. Factorial 2X5 ANOVA with Bonferroni correction, followed by a paired t test and Tukey test, was used for statistical analysis. The highest Fmax values were observed for the JJ group when using the dominant hand,followed by the JU, RO, AI and NA groups. Variation in Fmax could be attributed to handdominance (30.9%, sports modality (39.9% and the interaction between hand dominance andsport (21.3%. The present results demonstrated significant differences in Fmax between the JJ and AI groups and between the JJ and NA groups for both the dominant and non-dominant hand. Significant differences in Fmax between the dominant and non-dominant hand were only observed in the AI and NA groups. The results indicate that Fmax can be used for comparisonbetween different sports modalities, and to identify differences between the dominant and nondominanthand. Studies involving a larger number of subjects will permit the identification of differences between other modalities.

  13. Does grip strength on the unaffected side of patients with hemiparetic stroke reflect the strength of other ipsilateral muscles?

    Science.gov (United States)

    Takahashi, Jumpei; Nishiyama, Toru; Matsushima, Yoshimasa

    2017-01-01

    [Purpose] Grip strength is used as an indicator of overall body muscular strength. However, most studies on grip strength have been performed in healthy people, and no study has evaluated it in the unaffected side of patients with hemiparetic stroke. The purpose of this study was to determine if grip strength on the unaffected side of patients with hemiparetic stroke correlates with the strength of other ipsilateral musculature. [Subjects and Methods] The maximal strengths of the muscles on the unaffected side of 31 patients with hemiparetic stroke were measured, and correlation coefficients were calculated. [Results] The results revealed significant positive correlations between grip strength on the unaffected side and the strength of the other ipsilateral muscle groups, with relatively high correlations being observed for the upper extremity muscle groups. [Conclusion] This suggests that grip strength on the unaffected side of patients with hemiparetic stroke can be used as a simple way to estimate overall strength on that side.

  14. Hand grip strength in patients with chronic obstructive pulmonary disease

    Directory of Open Access Journals (Sweden)

    Jeong M

    2017-08-01

    Full Text Available Moa Jeong,1 Hyung Koo Kang,1 Pamela Song,2 Hye Kyeong Park,1 Hoon Jung,1 Sung-Soon Lee,1 Hyeon-Kyoung Koo1 1Division of Pulmonary and Critical Care Medicine, Department of Internal Medicine, 2Department of Neurology, Ilsan Paik Hospital, Inje University College of Medicine, Goyang, Republic of Korea Purpose: Hand grip strength (HGS is a simple way of predicting the risk of cardiovascular disease and all-cause mortality in the general population. However, the practical significance of grip strength in patients with COPD is uncertain. The aim of this study was to compare HGS between subjects with and without COPD and to evaluate its clinical relevance in patients with COPD by using a national survey.Methods: Data were collected from the Korean National Health and Nutrition Examination Survey. The study included 421 adults with COPD and 2,542 controls who completed questionnaires, spirometry, and a HGS test. HGS was compared between subjects with and without COPD, and the association between grip strength, lung function, and quality of life (QoL was evaluated.Results: The mean HGS was 33.3±9.1 kg in the COPD group and 29.9±9.5 kg in the non-COPD group; adjusted HGS was 30.9±0.33 kg and 30.9±0.11 kg, respectively (P=0.99. HGS was not related to forced vital capacity (β=0.04, P=0.70 or forced expiratory volume in 1 second (β=0.11, P=0.24 in multivariable analysis. HGS was independently associated with the EQ-5D index, but the relationship was stronger in the COPD group (β=0.30, P<0.001 than in the non-COPD group (β=0.21, P<0.001. The results were similar for each component of the EQ-5D, including mobility (β=-0.25, P<0.001, daily activity (β=-0.19, P=0.01, pain/discomfort (β=-0.32, P<0.001, and anxiety/depression (β=-0.16, P=0.01.Conclusion: HGS was not different between subjects with and without COPD, but was associated with QoL – including mobility, daily activity, pain/discomfort, and anxiety/depression – in patients with COPD. The

  15. Relation between hand grip strength, respiratory muscle strength and spirometric measures in male nursing home residents.

    Science.gov (United States)

    Bahat, Gulistan; Tufan, Asli; Ozkaya, Hilal; Tufan, Fatih; Akpinar, Timur Selçuk; Akin, Sibel; Bahat, Zumrut; Kaya, Zuleyha; Kiyan, Esen; Erten, Nilgün; Karan, Mehmet Akif

    2014-09-01

    Adverse-outcomes related to sarcopenia are mostly mentioned as physical disability. As the other skeletal muscles, respiratory muscles may also be affected by sarcopenia. Respiratory muscle strength is known to affect pulmonary functions. Therefore, we aimed to investigate the relations between extremity muscle strength, respiratory muscle strengths and spirometric measures in a group of male nursing home residents. Among a total of 104 male residents, residents with obstructive measures were excluded and final study population was composed of 62 residents. Mean age was 70.5 ± 6.7 years, body mass index: 27.7 ± 5.3 kg/m2 and dominant hand grip strength: 29.7 ± 6.5 kg. Hand grip strength was positively correlated with maximal inspiratory pressure (MIP) and maximal expiratory pressure (MEP) (r = 0.35, p strength; among spirometric measures only parameter significantly related to grip strength was peak cough flow (PCF). The association of PCF with grip strength disappeared when MIP alone or "MIP and MEP" were included in the regression analysis. In the latter case, PCF was significantly associated only with MIP. We found peripheric muscle strength be associated with MIP and PCF but not with MEP or any other spirometric parameters. The relation between peripheral muscle strength and PCF was mediated by MIP. Our findings suggest that sarcopenia may affect inspiratory muscle strength earlier or more than the expiratory muscle strength. Sarcopenia may cause decrease in PCF in the elderly, which may stand for some common adverse respiratory complications.

  16. Genetic influences on the development of grip strength in adolescence.

    Science.gov (United States)

    Isen, Joshua; McGue, Matt; Iacono, William

    2014-06-01

    Enhanced physical strength is a secondary sex characteristic in males. Sexual dimorphism in physical strength far exceeds sex differences in stature or total body mass, suggesting a legacy of intense sexual selection. Upper-body strength is a particularly promising marker of intrasexual competitiveness in young men. Consequently, it is assumed that sex-influenced gene expression contributes to the development of physical strength. It is unclear, however, whether the underlying sources of individual differences in strength development are comparable across sex. We obtained three measurements of hand-grip strength (HGS) over a six-year period spanning adolescence in male and female same-sex twins (N = 2,513). Biometrical latent growth models were used to partition the HGS variance at age 11 (intercept) and its growth over time (slope) into genetic and environmental components. Results demonstrated that variance around the intercept was highly heritable in both males and females (88% and 79%, respectively). In males, variance around the slope exceeded that of the intercept, while the reverse held for females. Additive genetic effects accounted for most (80%) of the variance around the slope in males, but were of less importance in females (heritability = 28%). Absolute genetic variance around the slope was nearly nine-fold higher in males. This striking disparity suggests that the developmental processes shaping HGS growth are different between the sexes. We propose that this might account for the sex-specific pattern of associations between HGS and external measures (e.g., digit ratio and physical aggression) typically reported in the literature. Our results underscore the role of endogenous androgenic influences in the development of physical strength.

  17. The Effect of Handedness on Grip Strength in Older Adults with Intellectual Disabilities

    Science.gov (United States)

    Oppewal, Alyt; Hilgenkamp, Thessa I. M.; van Wijck, Ruud; Evenhuis, Heleen M.

    2013-01-01

    Grip strength is an important predictor of several health outcomes in the general older population. Grip strength assessment is feasible and reliable in older adults with intellectual disabilities (ID), which makes it a valuable measurement for application in this population. The purpose of this study was to investigate the effect of handedness on…

  18. Children with flat feet have weaker toe grip strength than those having a normal arch

    Science.gov (United States)

    Tashiro, Yuto; Fukumoto, Takahiko; Uritani, Daisuke; Matsumoto, Daisuke; Nishiguchi, Shu; Fukutani, Naoto; Adachi, Daiki; Hotta, Takayuki; Morino, Saori; Shirooka, Hidehiko; Nozaki, Yuma; Hirata, Hinako; Yamaguchi, Moe; Aoyama, Tomoki

    2015-01-01

    [Purpose] This study investigated the relationship between toe grip strength and foot posture in children. [Subjects and Methods] A total of 619 children participated in this study. The foot posture of the participants was measured using a foot printer and toe grip strength was measured using a toe grip dynamometer. Children were classified into 3 groups; flatfoot, normal, and high arch, according to Staheli’s arch index. The differences in demographic data and toe grip strength among each foot posture group were analyzed by analysis of variance. Additionally, toe grip strength differences were analyzed by analysis of covariance, adjusted to body mass index, age, and gender. [Results] The number of participants classified as flatfoot, normal, and high arch were 110 (17.8%), 468 (75.6%), and 41 (6.6%), respectively. The toe grip strength of flatfoot children was significantly lower than in normal children, as shown by both analysis of variance and analysis of covariance. [Conclusion] A significant difference was detected in toe grip strength between the low arch and normal foot groups. Therefore, it is suggested that training to increase toe grip strength during childhood may prevent the formation of flat feet or help in the development of arch. PMID:26696732

  19. lateral asymmetry ш grip strength: utility of the ten per cent rule

    African Journals Online (AJOL)

    2001-11-01

    Nov 1, 2001 ... between strengths of dominant and non-dominant hands. Such discrepancy in ... methodological approaches in evaluation of grip strength, different .... Relations between stronger hand and hand preference. Stronger hand.

  20. Effects of kinesio tape compared with non-elastic tape on hand grip strength.

    Science.gov (United States)

    Kim, Ji Young; Kim, Seong Yeol

    2016-05-01

    [Purpose] Many assumptions have been made about taping and several studies have considered tape application methods; however, the true effect of taping on muscle strength remains unclear. Most previous studies compared application techniques using Kinesio tape (KT), but studies that compared muscle strength using non-elastic tape (NT) are limited. Moreover, no studies have applied KT and NT in the same way to assess grip strength in normal subjects. The purpose of this study was to evaluate the immediate effect of application of two tapes with different elastic properties on maximal grip strength in healthy adults. [Subjects and Methods] Twenty healthy adults were divided into two groups (KT and NT). Maximal grip strength was measured with a dynamometer. Forearm extensor muscles of the dominant hand were then taped and subjects were immediately asked to perform hand grip movement with maximum strength in the same standardized manner. [Results] In the KT group, maximal grip strength was significantly increased compared to the initial value; however, in the NT group, there was no significant difference in maximal grip strength. [Conclusion] This study suggests that only Kinesio tape can increase maximal grip strength immediately after application on the extensor region of the forearm.

  1. Effects of kinesio tape compared with non-elastic tape on hand grip strength

    Science.gov (United States)

    Kim, Ji Young; Kim, Seong Yeol

    2016-01-01

    [Purpose] Many assumptions have been made about taping and several studies have considered tape application methods; however, the true effect of taping on muscle strength remains unclear. Most previous studies compared application techniques using Kinesio tape (KT), but studies that compared muscle strength using non-elastic tape (NT) are limited. Moreover, no studies have applied KT and NT in the same way to assess grip strength in normal subjects. The purpose of this study was to evaluate the immediate effect of application of two tapes with different elastic properties on maximal grip strength in healthy adults. [Subjects and Methods] Twenty healthy adults were divided into two groups (KT and NT). Maximal grip strength was measured with a dynamometer. Forearm extensor muscles of the dominant hand were then taped and subjects were immediately asked to perform hand grip movement with maximum strength in the same standardized manner. [Results] In the KT group, maximal grip strength was significantly increased compared to the initial value; however, in the NT group, there was no significant difference in maximal grip strength. [Conclusion] This study suggests that only Kinesio tape can increase maximal grip strength immediately after application on the extensor region of the forearm. PMID:27313372

  2. Hand-grip strength cut points to screen older persons at risk for mobility limitation.

    Science.gov (United States)

    Sallinen, Janne; Stenholm, Sari; Rantanen, Taina; Heliövaara, Markku; Sainio, Päivi; Koskinen, Seppo

    2010-09-01

    To determine optimal hand-grip strength cut points for likelihood of mobility limitation in older people and to study whether these cut points differ according to body mass index (BMI). Cross-sectional analysis of data. Data collected in the Finnish population-based Health 2000 Survey. One thousand eighty-four men and 1,562 women aged 55 and older with complete data on anthropometry, hand-grip strength and self-reported mobility. Mobility limitation was defined as difficulty walking 0.5 km or climbing stairs. Receiver operating characteristic analysis was used to estimate hand-grip strength cut points for likelihood of mobility limitation. The overall hand-grip strength cut points for likelihood of mobility limitation were 37 kg (sensitivity 62%; specificity 76%) for men and 21 kg (sensitivity 67%; specificity 73%) for women. The effect of the interaction between hand-grip strength and BMI on mobility limitation was significant in men (P=.02), but no such interaction was observed in women (P=.16). In men, the most-optimal cutoff points were 33 kg (sensitivity 73%; specificity 79%) for normal-weight men, 39 kg (sensitivity 67%; specificity 71%) for overweight men, and 40 kg (sensitivity 57%; specificity 68%) for obese men. In women, BMI-specific hand-grip strength cutoff values was not markedly more accurate than the overall cutoff value. The hand-grip strength test is a useful tool to identify persons at risk of mobility limitation. In men, hand-grip strength cut points for mobility increased with BMI, whereas in women, only one hand-grip strength threshold was identified. © 2010, Copyright the Authors. Journal compilation © 2010, The American Geriatrics Society.

  3. Posture, Flexibility and Grip Strength in Horse Riders

    Directory of Open Access Journals (Sweden)

    Hobbs Sarah Jane

    2014-10-01

    Full Text Available Since the ability to train the horse to be ambidextrous is considered highly desirable, rider asymmetry is recognized as a negative trait. Acquired postural and functional asymmetry can originate from numerous anatomical regions, so it is difficult to suggest if any is developed due to riding. The aim of this study was therefore to assess symmetry of posture, strength and flexibility in a large population of riders and to determine whether typical traits exist due to riding. 127 right handed riders from the UK and USA were categorized according to years riding (in 20 year increments and their competition level (using affiliated test levels. Leg length, grip strength and spinal posture were measured and recorded by a physiotherapist. Standing and sitting posture and trunk flexibility were measured with 3-D motion capture technology. Right-left differences were explored in relation to years riding and rider competitive experience. Significant anatomical asymmetry was found for the difference in standing acromion process height for a competition level (-0.07±1.50 cm Intro/Prelim; 0.02±1.31 cm Novice; 0.43±1.27 cm Elementary+; p=0.048 and for sitting iliac crest height for years riding (-0.23±1.36 cm Intro/Prelim; 0.01±1.50 cm Novice; 0.86±0.41 cm Elementary+; p=0.021. For functional asymmetry, a significant interaction was found for lateral bending ROM for years riding x competition level (p=0.047. The demands on dressage riders competing at higher levels may predispose these riders to a higher risk of developing asymmetry and potentially chronic back pain rather than improving their symmetry

  4. Posture, flexibility and grip strength in horse riders.

    Science.gov (United States)

    Hobbs, Sarah Jane; Baxter, Joanna; Broom, Louise; Rossell, Laura-Ann; Sinclair, Jonathan; Clayton, Hilary M

    2014-09-29

    Since the ability to train the horse to be ambidextrous is considered highly desirable, rider asymmetry is recognized as a negative trait. Acquired postural and functional asymmetry can originate from numerous anatomical regions, so it is difficult to suggest if any is developed due to riding. The aim of this study was therefore to assess symmetry of posture, strength and flexibility in a large population of riders and to determine whether typical traits exist due to riding. 127 right handed riders from the UK and USA were categorized according to years riding (in 20 year increments) and their competition level (using affiliated test levels). Leg length, grip strength and spinal posture were measured and recorded by a physiotherapist. Standing and sitting posture and trunk flexibility were measured with 3-D motion capture technology. Right-left differences were explored in relation to years riding and rider competitive experience. Significant anatomical asymmetry was found for the difference in standing acromion process height for a competition level (-0.07±1.50 cm Intro/Prelim; 0.02±1.31 cm Novice; 0.43±1.27 cm Elementary+; p=0.048) and for sitting iliac crest height for years riding (-0.23±1.36 cm Intro/Prelim; 0.01±1.50 cm Novice; 0.86±0.41 cm Elementary+; p=0.021). For functional asymmetry, a significant interaction was found for lateral bending ROM for years riding x competition level (p=0.047). The demands on dressage riders competing at higher levels may predispose these riders to a higher risk of developing asymmetry and potentially chronic back pain rather than improving their symmetry.

  5. Immediate and Delayed Effects of Forearm Kinesio Taping on Grip Strength

    Science.gov (United States)

    Kouhzad Mohammadi, Hosein; Khademi Kalantari, Khosro; Naeimi, Sedighe Sadat; Pouretezad, Mohammad; Shokri, Esmaeil; Tafazoli, Mojdeh; Dastjerdi, Mahboobeh; Kardooni, Leila

    2014-01-01

    Background: Due to the fundamental role of gripping in most upper limb activities, grip strength promotion is a chief goal in the treatment of patients with upper limb musculoskeletal disorders. Kinesio taping is a novel and effective therapeutic technique believed to facilitate muscle contraction through stimulating mechanoreceptors and increasing the sensory feedback around the taped region. Objectives: The present study aimed to identify the best region (flexor, extensor and flexor/extensor regions) and time (immediate, 0.5, 1, 1.5, and 2 hours) of forearm Kinesio taping to obtain the maximum improvement in grip strength. Materials and Methods: In this longitudinal study, 40 healthy men and women (the mean age of 22.3 ± 2.19 years) were selected among students of Shahid Beheshti University of Medical Sciences, Tehran, Iran by simple, nonrandom sampling method. A dynamometer was used to measure grip strength immediately and every 30 minutes during the two hours after I-shaped application of tape (with 50% stretch) to the flexor, extensor, and flexor/extensor forearm muscles. Results: Grip strength was significantly increased in various muscle groups for males (P = 0.002) and females (P = 0.000) of the forearm and at different intervals for males (P = 0.000) and females (P = 0.000). Moreover, in both men and women, tape application to the extensor region provided greater grip strength compared to taping of the flexor and flexor/extensor regions (P = 0.000 for both). Furthermore, the maximum increase in grip strength were 0.5 (10.8% increase, P = 0.001) and 1.5 h (23.9% increase, P = 0.000) after taping in males and females, respectively. Conclusions: Taping the extensor region of forearm is recommended to achieve higher grip strength. Although grip strength increased at a slower pace in females than males, the final values were higher in women. PMID:25389492

  6. Normative Measurements of Grip and Pinch Strengths of 21st Century Korean Population

    Directory of Open Access Journals (Sweden)

    Jin Hee Shim

    2013-01-01

    Full Text Available BackgroundMeasuring grip and pinch strength is an important part of hand injury evaluation. Currently, there are no standardized values of normal grip and pinch strength among the Korean population, and lack of such data prevents objective evaluation of post-surgical recovery in strength. This study was designed to establish the normal values of grip and pinch strength among the healthy Korean population and to identify any dependent variables affecting grip and pinch strength.MethodsA cross-sectional study was carried out. The inclusion criterion was being a healthy Korean person without a previous history of hand trauma. The grip strength was measured using a Jamar dynamometer. Pulp and key pinch strength were measured with a hydraulic pinch gauge. Intra-individual and inter-individual variations in these variables were analyzed in a standardized statistical manner.ResultsThere were a total of 336 healthy participants between 13 and 77 years of age. As would be expected in any given population, the mean grip and pinch strength was greater in the right hand than the left. Male participants (137 showed mean strengths greater than female participants (199 when adjusted for age. Among the male participants, anthropometric variables correlated positively with grip strength, but no such correlations were identifiable in female participants in a statistically significant way.ConclusionsObjective measurements of hand strength are an important component of hand injury evaluation, and population-specific normative data are essential for clinical and research purposes. This study reports updated normative hand strengths of the South Korean population in the 21st century.

  7. [Isometric grip strength and social gerontological research: results and analytic potentials of SHARE and SOEP].

    Science.gov (United States)

    Hank, K; Jürges, H; Schupp, J; Wagner, G G

    2009-04-01

    This paper shows that the measurement of hand grip strength provides a non-invasive and reliable objective health indicator for social science research and is easy to collect in general population surveys. Grip strength is not only a useful complement of self-reported indicators of health, but it also exhibits a considerable predictive power with regard to a number of further relevant variables for social gerontological research, such as mortality risks. New data from the 2004 Survey of Health, Ageing and Retirement in Europe (SHARE) and the 2006 wave of the German Socio-Economic Panel Study (SOEP) allow insightful methodological and very first substantive cross-sectional analyses of grip strength in Germany. The focus of the present study is on the analysis of individuals aged 50 or older. The experience of both surveys when measuring grip strength is consistently positive, particularly with regard to the respondents' feedback. Major determinants of isometric grip strength are - beyond the individual's gender - age, body size and weight. A multivariate analysis also provides evidence for a clear positive association between various health indicators and grip strength.

  8. Adductor pollicis muscle and hand grip strength: potential methods of nutritional assessment in outpatients with stroke

    Directory of Open Access Journals (Sweden)

    Débora Rocha Oliveira

    2010-12-01

    Full Text Available Objective: To evaluate and compare the effectiveness of different methods used for nutritional assessment of outpatients who had hemiplegic stroke. Methods: A cross-section study with adult and elderly patients of both genders enrolled in a rehabilitation center. The analyzed variables were anthropometric measurements, bioelectrical impedance, hand grip strength and thickness of the adductor pollicis muscle. The Pearson χ2 test was used to check the association between variables with a significance level of α = 5%. Results: When evaluating the association between indicators of muscle mass, it was observed that the hand grip strength in both genders was positively correlated with arm muscle circumference (p = 0.0196 and lean mass (p = 0.0002. Fat mass measured by the bioelectrical impedance method already showed a significant inverse relationship with the grip (r = -0.3879. The thickness of the adductor pollicis muscle showed significant association with lean mass (p = 0.0052 and hand grip (p = 0.0024. Conclusion: In this study, the hand grip strength and thickness of the adductor pollicis muscle were well correlated with measurements determined by anthropometry and bioimpedance. The results show the applicability of grip strength and thickness of the adductor pollicis muscle in clinical practice as nutritional assessment methods for this population, especially elderly patients, since they detect functional changes not captured by other parameters in the short term and are important for early identification of risk nutrition.

  9. Effects of Taping on Pain, Grip Strength and Wrist Extension Force in Patients with Tennis Elbow

    Science.gov (United States)

    Shamsoddini, Alireza; Hollisaz, Mohammad Taghi

    2013-01-01

    Background Tennis elbow (TE) is a common musculotendinous degenerative disorder of the extensor origin at the lateral humeral epicondyle. Different modes of treatment are used for management of tennis elbow. Objectives This study investigated the effect of the taping technique (TT) on pain, grip strength and wrist extension force in treatment of tennis elbow. Patients and Methods Thirty patients (16 men /14 women with a mean age of 32.2 years) with tennis elbow of their dominant arm participated in this study. Outcome measures were assessment of pain at the lateral aspect of the elbow, grip strength and wrist extension force before and five to ten minutes after application of elbow tape on the affected and unaffected arms. A Visual Analog Scale was used to assess pain. A dynamometer and a hand-held dynamometer were used for evaluation of grip strength and wrist extension force, respectively. Results Among the variables, significant differences were found in wrist extension forces between effected and unaffected arms (P = 0.02). Changes in grip strength showed statically significant improvements in the affected arm compared to the unaffected arm (P = 0.03). Also, in assessment of pain at the lateral epicondyle, the mean change between affected and unaffected arms was significant, with P = 0.001. Conclusions The taping technique, as applied in this study demonstrates an impressive effect on wrist extension force and grip strength of patients with TE. Elbow taping also reduces pain at the lateral aspect of the elbow in these patients. PMID:24350156

  10. An investigation of the association between grip strength and hip and knee joint moments in older adults.

    Science.gov (United States)

    Samuel, Dinesh; Rowe, Philip

    2012-01-01

    Grip strength is a predictor of health outcomes but with differing rates of age-related decline in muscle strength, it is unclear whether handgrip is a reliable indicator of lower limb moments. This study investigated the relationship between grip strength and lower extremity moments in community-dwelling older adults. Eighty-two healthy volunteers aged 60-82 years (mean age 73.2 years) performed maximal voluntary contractions of knee and hip extensors and flexors at three positions and at neutral position for hip abductors and adductors using a custom-built dynamometer. Grip strength was measured using an electronic Jamar dynamometer. The relative reduction in muscle strength of 80s age category compared to 60-year-olds ranged from 14% for grip strength to 27% for hip abductors. Peak torque of flexors and extensors of the knee and hip joints were significantly correlated with grip strength and Pearson's correlation coefficients ranged from 0.56 to 0.78 with the highest correlations observed between knee moments and grip strength. "Good" correlation was found but only 31-60% of the variation in grip strength could be related to changes in joint torques. Hence the assumption that grip strength is an indicator of strength in the lower limb would seem unjustified in the healthy older adult.

  11. Relationship between grip, pinch strengths and anthropometric variables, types of pitch throwing among Japanese high school baseball pitchers.

    Science.gov (United States)

    Tajika, Tsuyoshi; Kobayashi, Tsutomu; Yamamoto, Atsushi; Shitara, Hitoshi; Ichinose, Tsuyoshi; Shimoyama, Daisuke; Okura, Chisa; Kanazawa, Saeko; Nagai, Ayako; Takagishi, Kenji

    2015-03-01

    Grip and pinch strength are crucially important attributes and standard parameters related to the functional integrity of the hand. It seems significant to investigate normative data for grip and pinch strength of baseball players to evaluate their performance and condition. Nevertheless, few reports have explained the association between grip and pinch strength and anthropometric variables and types of pitch throwing for baseball pitchers. The aim of this study was to measure and evaluate clinical normative data for grip and tip, key, palmar pinch strength and to assess the relationship between these data and anthropometric variables and types of pitch throwing among Japanese high-school baseball pitchers. One hundred-thirty three healthy high school baseball pitchers were examined and had completed a self-administered questionnaire including items related to age, hand dominance, throwing ratio of type of pitch. A digital dynamometer was used to measure grip strength and a pinch gauge to measure tip, key and palmer pinch in both dominant and nondominant side. Body composition was measured by the multi frequency segmental body composition analyzer. Grip strength and tip and palmer pinch strength in dominant side were statistically greater than them in nondominant side (P types of pitches thrown and grip strength and tip, key, palmar pinch strength. Our result provides normative values and evidences for grip and pinch strengths in high school baseball pitchers.

  12. Grip Strength as a Marker of Hypertension and Diabetes in Healthy Weight Adults.

    Science.gov (United States)

    Mainous, Arch G; Tanner, Rebecca J; Anton, Stephen D; Jo, Ara

    2015-12-01

    Muscle strength may play a role in cardiometabolic disease. We examined the relationship between hand grip strength and diabetes and hypertension in a sample of healthy weight adults. In 2015, we analyzed the National Health and Nutrition Examination Survey 2011-2012 for adults aged ≥20 years with healthy BMIs (between 18.5 and Hypertension was based on measured blood pressure and reported hypertension diagnosis. Individuals with undiagnosed diabetes compared with individuals without diabetes had lower grip strength (51.9 vs 69.8, p=0.0001), as did individuals with diagnosed diabetes compared with individuals without diabetes (61.7 vs 69.8, p=0.008). Mean grip strength was lower among individuals with undiagnosed hypertension compared with individuals without hypertension (63.5 vs 71.5, p=0.008) as well as among individuals with diagnosed hypertension compared with those without hypertension (60.8 vs 71.5, phypertension (β=-6.6, p=0.004) and diagnosed hypertension (β=-4.27, p=0.04) compared with individuals without hypertension. Among healthy weight adults, combined grip strength is lower in individuals with diagnosed and undiagnosed diabetes and hypertension. Copyright © 2015 American Journal of Preventive Medicine. Published by Elsevier Inc. All rights reserved.

  13. Grip strength and lower limb extension power in 19-72-year-old Danish men and women

    DEFF Research Database (Denmark)

    Aadahl, Mette; Beyer, Nina; Linneberg, Allan

    2011-01-01

    To assess muscular fitness by hand grip strength (HGS) and lower limb extension power (LEP) and to explore associations with age, leisure time physical activity (LTPA) and body composition.......To assess muscular fitness by hand grip strength (HGS) and lower limb extension power (LEP) and to explore associations with age, leisure time physical activity (LTPA) and body composition....

  14. Large-scale GWAS identifies multiple loci for hand grip strength providing biological insights into muscular fitness

    DEFF Research Database (Denmark)

    Willems, Sara M; Wright, Daniel J.; Day, Felix R

    2017-01-01

    Hand grip strength is a widely used proxy of muscular fitness, a marker of frailty, and predictor of a range of morbidities and all-cause mortality. To investigate the genetic determinants of variation in grip strength, we perform a large-scale genetic discovery analysis in a combined sample of 1...

  15. Large-scale GWAS identifies multiple loci for hand grip strength providing biological insights into muscular fitness

    NARCIS (Netherlands)

    Willems, Sara M.; Wright, D.J.; Day, Felix R.; Trajanoska, Katerina; Joshi, P.K.; Morris, John A.; Matteini, Amy M.; Garton, Fleur C.; Grarup, Niels; Oskolkov, Nikolay; Thalamuthu, Anbupalam; Mangino, Massimo; Liu, Jun; Demirkan, Ayse; Lek, Monkol; Xu, Liwen; Wang, Guan; Oldmeadow, Christopher; Gaulton, Kyle J.; Lotta, Luca A.; Miyamoto-Mikami, Eri; Rivas, Manuel A.; White, Tom; Loh, Po Ru; Aadahl, Mette; Amin, Najaf; Attia, John R.; Austin, Krista; Benyamin, Beben; Brage, Søren; Cheng, Yu Ching; Ciȩszczyk, Paweł; Derave, Wim; Eriksson, Karl Fredrik; Eynon, Nir; Linneberg, Allan; Lucia, Alejandro; Massidda, Myosotis; Mitchell, Braxton D.; Miyachi, Motohiko; Murakami, Haruka; Padmanabhan, Sandosh; Pandey, Ashutosh; Papadimitriou, Ioannis; Rajpal, Deepak K.; Sale, Craig; Schnurr, Theresia M.; Sessa, Francesco; Shrine, Nick; Tobin, Martin D.; Varley, Ian; Wain, Louise V.; Wray, Naomi R.; Lindgren, Cecilia M.; MacArthur, Daniel G.; Waterworth, Dawn M.; McCarthy, Mark I.; Pedersen, Oluf; Khaw, Kay Tee; Kiel, Douglas P.; Pitsiladis, Yannis; Fuku, Noriyuki; Franks, Paul W.; North, Kathryn N.; Duijn, Van C.M.; Mather, Karen A.; Hansen, Torben; Hansson, Ola; Spector, Tim D.; Murabito, Joanne M.; Richards, J.B.; Rivadeneira, Fernando; Langenberg, Claudia; Perry, John R.B.; Wareham, Nick J.; Scott, Robert A.; Oei, Ling; Zheng, Hou Feng; Forgetta, Vincenzo; Leong, Aaron; Ahmad, Omar S.; Laurin, Charles; Mokry, Lauren E.; Ross, Stephanie; Elks, Cathy E.; Bowden, Jack; Warrington, Nicole M.; Murray, Anna; Ruth, Katherine S.; Tsilidis, Konstantinos K.; Medina-Gómez, Carolina; Estrada, Karol; Bis, Joshua C.; Chasman, Daniel I.; Demissie, Serkalem; Enneman, Anke W.; Hsu, Yi Hsiang; Ingvarsson, Thorvaldur; Kähönen, Mika; Kammerer, Candace; Lacroix, Andrea Z.; Li, Guo; Liu, Ching Ti; Liu, Yongmei; Lorentzon, Mattias; Mägi, Reedik; Mihailov, Evelin; Milani, Lili; Moayyeri, Alireza; Nielson, Carrie M.; Sham, Pack Chung; Siggeirsdotir, Kristin; Sigurdsson, Gunnar; Stefansson, Kari; Trompet, Stella; Thorleifsson, Gudmar; Vandenput, Liesbeth; Velde, Van Der Nathalie; Viikari, Jorma; Xiao, Su Mei; Zhao, Jing Hua; Evans, Daniel S.; Cummings, Steven R.; Cauley, Jane; Duncan, Emma L.; Groot, De Lisette C.P.G.M.; Esko, Tonu; Gudnason, Vilmundar; Harris, Tamara B.; Jackson, Rebecca D.; Jukema, J.W.; Ikram, Arfan M.A.; Karasik, David; Kaptoge, Stephen; Kung, Annie Wai Chee; Lehtimäki, Terho; Lyytikäinen, Leo Pekka; Lips, Paul; Luben, Robert; Metspalu, Andres; Meurs, van Joyce B.; Minster, Ryan L.; Orwoll, Erick; Oei, Edwin; Psaty, Bruce M.; Raitakari, Olli T.; Ralston, Stuart W.; Ridker, Paul M.; Robbins, John A.; Smith, Albert V.; Styrkarsdottir, Unnur; Tranah, Gregory J.; Thorstensdottir, Unnur; Uitterlinden, Andre G.; Zmuda, Joseph; Zillikens, M.C.; Ntzani, Evangelia E.; Evangelou, Evangelos; Ioannidis, John P.A.; Evans, David M.; Ohlsson, Claes

    2017-01-01

    Hand grip strength is a widely used proxy of muscular fitness, a marker of frailty, and predictor of a range of morbidities and all-cause mortality. To investigate the genetic determinants of variation in grip strength, we perform a large-scale genetic discovery analysis in a combined sample of 195,

  16. Age trajectories of grip strength: cross-sectional and longitudinal data among 8,342 Danes aged 46 to 102

    DEFF Research Database (Denmark)

    Frederiksen, Henrik; Hjelmborg, Jacob; Mortensen, Jakob

    2006-01-01

    with increasing age. Estimates were obtained by using full-information methods from large population-representative studies. Equations of expected grip strength, as well as tables with sex-, age-, and height-stratified reference data, provide an opportunity to include grip-strength measurement in clinical care...

  17. EFFECT OF ECCENTRIC EXERCISE PROGRAMME ON PAIN AND GRIP STRENGTH FOR SUBJECTS WITH MEDIAL EPICONDYLITIS

    Directory of Open Access Journals (Sweden)

    Mishra Prashant Akhilesh

    2014-04-01

    Full Text Available Background and Objective: Therapeutic eccentric exercise may provide both a structural and functional benefit during tendinopathy rehabilitation. The objective is to find the effect of eccentric exercises on improvement of pain and grip strength for subjects with Medial Epicondylitis. Method: Pre to post test experimental study design randomized thirty subjects with medial epicondylitis, 15 each into Group A and Group B. Group B subjects were treated with conventional therapy and Eccentric exercises. Group A subjects were treated with conventional therapy. Results: When means of post intervention were compared using Independent ‘t’ between groups there was no statistically significant difference in improvements obtained in VAS scores and grip strength. There was a statistically significant change in means of VAS score and Grip strength when means were analyzed by using Paired‘t’ test and Wilcoxon signed rank test within the groups with positive percentage of change. Conclusion: It is concluded that four weeks of Eccentric Exercise Programme combined with conventional therapy shown significant effect on improving pain and Grip strength, however the improvement obtained has no difference when compared with control conventional treatment for Subjects with Medial Epicondylitis.

  18. Evaluation of total grip strength and individual finger forces on opposing (A-type) handles among Koreans.

    Science.gov (United States)

    Kong, Yong-Ku; Seo, Min-Tae; Kang, Hyun-Sung

    2014-01-01

    The present study evaluated the effect of grip span on finger forces and defined the best grip span for maximising total grip strength based on the finger forces and subjective discomfort in a static exertion. Five grip spans (45, 50, 55, 60 and 65 mm) of the opposing (A-type) handle shape were tested in this study to measure total grip strength and individual finger force among Korean population. A total of 30 males who participated in this study were asked to exert a maximum grip force with two repetitions, and to report the subjective discomfort experienced between exertions using the Borg's CR-10 scale. The highest grip strength was obtained at 45 mm and 50 mm grip spans. Results also showed that forces of all fingers, except for the middle finger force, significantly differed over the grip spans. The lowest subjective discomfort was observed in the 50 mm grip span. The results might be used as development guidelines for ergonomic opposing (A-type) hand tools for Korean population.

  19. Effects of Taping on Pain, Grip Strength and Wrist Extension Force in Patients with Tennis Elbow

    Directory of Open Access Journals (Sweden)

    Alireza Shamsoddini

    2013-09-01

    Full Text Available Background: Tennis elbow (TE is a common musculotendinous degenerative disorder of the extensor origin at the lateral humeral epicondyle. Different modes of treatment are used for management of tennis elbow.Objectives: This study investigated the effect of the taping technique (TT on pain, grip strength and wrist extension force in treatment of tennis elbow.Patients and Methods: Thirty patients (16 men /14 women with a mean age of 32.2 years with tennis elbow of their dominant arm participated in this study. Outcome measures were assessment of pain at the lateral aspect of the elbow, grip strength and wrist extension force before and five to ten minutes after application of elbow tape on the affected and unaffected arms. A Visual Analog Scale was used to assess pain. A dynamometer and a hand-held dynamometer were used for evaluation of grip strength and wrist extension force, respectively.Results: Among the variables, significant differences were found in wrist extension forces between effected and unaffected arms (P = 0.02. Changes in grip strength showed statically significant improvements in the affected arm compared to the unaffected arm (P = 0.03. Also, in assessment of pain at the lateral epicondyle, the mean change between affected and unaffected arms was significant, with P = 0.001.Conclusions: The taping technique, as applied in this study demonstrates an impressive effect on wrist extension force and grip strength of patients with TE. Elbow taping also reduces pain at the lateral aspect of the elbow in these patients.

  20. Long-term outcome of muscle strength in ulnar and median nerve injury: Comparing manual muscle strength testing, grip and pinch strength dynamometers and a new intrinsic muscle strength dynamometer

    OpenAIRE

    Schreuders, Ton; Roebroeck, Marij; Jaquet, Jean; Hovius, Steven; Stam, Henk

    2004-01-01

    textabstractObjective: To compare the outcome of muscle strength with manual muscle strength testing grip and pinch strength measurements and a dynamometer which allows for measurements of the intrinsic muscles of the hand in isolation (the Rotterdam Intrinsic Hand Myometer, RIHM). Methods: Thirty-four patients more than 2 years after ulnar and/or median nerve injury. Muscle strength was evaluated using manual muscle strength testing (MMST), grip, pinch and intrinsic muscle strength measureme...

  1. Analysis of the statistical methods used to detect submaximal effort with the five-rung grip strength test.

    Science.gov (United States)

    Shechtman, Orit; Gutierrez, Zeida; Kokendofer, Emily

    2005-01-01

    Controversy exists in the literature concerning the ability of the five-rung grip test to identify submaximal effort. The purpose of this study was to analyze four methods commonly used to evaluate the shape of the curve generated by maximal versus submaximal efforts. Thirty hand therapy patients performed the five-rung grip test maximally and submaximally with both their injured and uninjured hands. Grip strength scores were recorded at each of the five-rung positions. Next, four methods were used to analyze the data 1) visual analysis, 2) analysis of variance, 3) normalization, and 4) calculation of the standard deviation across the five strength scores. Analysis by all methods demonstrated that there were no differences between the injured hand exerting maximal effort and the uninjured hand exerting submaximal effort. In all four methods, the five-rung grip strength test was unable to distinguish between the injured hand exerting maximal effort and the uninjured hand exerting submaximal effort. The results suggest that the five-rung grip strength test should not be used to determine sincerity of effort in people with hand injuries, and that the shape of the curve generated by the five-rung grip strength test may not be related to level of effort but rather to the amount of force generated by the gripping hand.

  2. Interobserver reproducibility of the assessment of severity of complaints, grip strength, and pressure pain threshold in patients with lateral epicondylitis.

    NARCIS (Netherlands)

    Smidt, N.; Windt, A. van der; Assendelft, W.J.; Mourits, A.J.; Devillé, W.L.; Winter, F. de; Bouter, L.M.

    2002-01-01

    Objective: To evaluate the interobserver reproducibility of the assessment of severity of complaints, grip strength, and pressure pain threshold in patients with lateral epicondylitis in primary care. Design: Two physiotherapists assessed independently, and in randomized order, the severity of

  3. Interobserver reproducibility of the assessment of severity of complaints, grip strength, and pressure pain threshold in patients with lateral epicondylitis

    NARCIS (Netherlands)

    Smidt, N; van der Windt, DA; Assendelft, WJ; Mourits, AJ; Deville, WL; de Winter, AF; Bouter, LM

    2002-01-01

    Objective: To evaluate the interobserver reproducibility of the assessment of severity of complaints, grip strength, and pressure pain threshold in patients with lateral epicondylitis in primary care. Design: Two physiotherapists assessed independently, and in randomized order, the severity of compl

  4. Interobserver reproducibility of the assessment of severity of complaints, grip strength, and pressure pain threshold in patients with lateral epicondylitis.

    NARCIS (Netherlands)

    Smidt, N.; Windt, A. van der; Assendelft, W.J.; Mourits, A.J.; Devillé, W.L.; Winter, F. de; Bouter, L.M.

    2002-01-01

    Objective: To evaluate the interobserver reproducibility of the assessment of severity of complaints, grip strength, and pressure pain threshold in patients with lateral epicondylitis in primary care. Design: Two physiotherapists assessed independently, and in randomized order, the severity of compl

  5. Nutritional status is the major factor affecting grip strength of African HIV patients before and during antiretroviral treatment

    DEFF Research Database (Denmark)

    Filteau, Suzanne; PrayGod, G; Woodd, Susannah L

    2017-01-01

    involved HIV-infected Zambian and Tanzanian participants recruited to the NUSTART trial when malnourished (body mass index requiring ART. The relationship of grip strength to nutritional, infectious and demographic factors was assessed by multivariable linear regression at referral...

  6. Nutritional status is the major factor affecting grip strength of African HIV patients before and during antiretroviral treatment.

    Science.gov (United States)

    Filteau, S; PrayGod, G; Woodd, S L; Friis, H; Heimburger, D C; Koethe, J R; Kelly, P; Kasonka, L; Rehman, A M

    2017-10-01

    Low grip strength is a marker of frailty and a risk factor for mortality among HIV patients and other populations. We investigated factors associated with grip strength in malnourished HIV patients at referral to ART, and at 12 weeks and 2-3 years after starting ART. The study involved HIV-infected Zambian and Tanzanian participants recruited to the NUSTART trial when malnourished (body mass index <18.5 kg/m(2) ) and requiring ART. The relationship of grip strength to nutritional, infectious and demographic factors was assessed by multivariable linear regression at referral for ART (n = 1742) and after 12 weeks (n = 778) and 2-3 years of ART (n = 273). In analyses controlled only for sex, age and height, most nutrition and infection-related variables were associated with grip strength. However, in multivariable analyses, consistent associations were seen for fat-free mass index, mid-upper arm circumference, haemoglobin and systolic blood pressure, and a variable association with fat mass index in men. C-reactive protein and CD4 count had limited independent effects on grip strength, while receiving tuberculosis treatment was associated with weaker grip strength. In this population of originally malnourished HIV patients, poor grip strength was more strongly and independently associated with nutritional than with infection and inflammation variables. Programmes to improve health and survival of HIV patients should incorporate nutritional assessment and management and could use grip strength as a functional indicator of improving nutrition. © 2017 John Wiley & Sons Ltd.

  7. REDUCED HAND GRIP STRENGTH IN OVERWEIGHT AND OBESE CHRONIC HEPATITIS C PATIENTS.

    Science.gov (United States)

    Bruch, Juliana Paula; Álvares-DA-Silva, Mário Reis; Alves, Bruna Cherubini; Dall'alba, Valesca

    2016-01-01

    Hepatitis C is a liver disease that causes significant changes in metabolism, and also has an impact on nutritional status. To evaluate the nutritional status and cardiovascular risk in patients with chronic hepatitis C. This cross-sectional study investigated 58 patients with chronic hepatitis C, non-cirrhotic and were not under active pharmacological treatment. Patients with significant alcohol consumption (greater than 10 g ethanol/day) were excluded. Patients underwent nutritional assessment through anthropometric measurements and functional assessment using hand grip strength by dynamometry. The physical activity was assessed using the International Physical Activity Questionnaire. Patients also underwent clinical and laboratory evaluation. Cardiovascular risk was calculated by the Framingham score. The mean age of patients was 51.6±9.7 years, 55.2% were female, and 79.3% had genotype 1. The most prevalent degree of fibrosis was F1 (37.9%) followed by F2 (27.6%) and F3 (1.7%). The prevalence of overweight/obesity considering the body mass index was 70.7%. However, 57.7% of men and 68.8% of women were considered malnourished according to hand grip strength. These patients also had waist circumference (93.5±10.7 cm) and neck circumference (37.0±3.6 cm) high. Almost 60% of patients were considered sedentary or irregularly active. In relation to cardiovascular risk, 50% of patients had high risk of suffering a cardiovascular event within 10 years. Although most patients with hepatitis C presented overweight, associated with high cardiovascular risk, they also have reduced functional capacity, indicative of protein-caloric commitment. Therefore, body mass index can not be considered the only method of assessment for nutritional diagnosis of patients with liver disease. Adopting methods such as hand grip strength can be important for a better understanding of nutritional status of these patients.

  8. Tongue Strength is Associated with Grip Strength and Nutritional Status in Older Adult Inpatients of a Rehabilitation Hospital.

    Science.gov (United States)

    Sakai, Kotomi; Nakayama, Enri; Tohara, Haruka; Maeda, Tomomi; Sugimoto, Motonobu; Takehisa, Takahiro; Takehisa, Yozo; Ueda, Koichiro

    2017-04-01

    The aim of this cross-sectional study was to investigate whether tongue strength observed in older adult inpatients of a rehabilitation hospital is associated with muscle function, nutritional status, and dysphagia. A total of 174 older adult inpatients aged 65 years and older in rehabilitation (64 men, 110 women; median age, 84 years; interquartile range, 80-89 years) who were suspected of having reduced tongue strength due to sarcopenia were included in this study. Isometric tongue strength was measured using a device fitted with a disposable oral balloon probe. We evaluated age, muscle function as assessed by the Barthel index and grip strength, nutritional status as measured by the Mini Nutritional Assessment-short form (MNA-SF), body mass index, serum albumin, controlling nutritional status, and calf circumference and arm muscle area to assess muscle mass. In addition, the functional oral intake scale (FOIS) was used as an index of dysphagia. Multivariate linear regression analysis revealed that isometric tongue strength was independently associated with grip strength (coefficient = 0.33, 95 % confidence interval (CI) 0.12-0.54, p = 0.002), MNA-SF (coefficient = 0.74, 95 % CI 0.12-1.35, p = 0.019), and FOIS (coefficient = 0.02, 95 % CI 0.00-0.15, p = 0.047). To maintain and improve tongue strength in association with sarcopenic dysphagia, exercise therapy and nutritional therapy interventions, as well as direct interventions to address tongue strength, may be effective in dysphagia rehabilitation in older adult inpatients.

  9. Is the coefficient of variation a valid measure for detecting sincerity of effort of grip strength?

    Science.gov (United States)

    Shechtman, Orit

    1999-01-01

    The wide use of the coefficient of variation in detecting sincerity of effort is puzzling since existing research findings regarding its effectiveness are contradictory. The lack of empirical support in the literature raises the question of whether or not the coefficient of variation is a valid measure for detecting sincerity of effort. Many clinicians, especially those who use a computer software to calculate the coefficient of variation, may not understand how the coefficient of variation is derived and what it is based on. The coefficient of variation is a measure of relative variability and would be used correctly only if the average and the standard deviation of grip strength trials increased proportionally. This case study, however, demonstrated that the average and standard deviation of grip strength are independent. Thus, the coefficient of variation is not a valid measure of sincerity of effort. In addition, this study indicated that the coefficient of variation may be inflated in individuals after carpal tunnel release surgery. The author, therefore, cautions clinicians against the use of the coefficient of variation as a measure of sincerity of effort especially in injured individuals with compromised hand strength.

  10. The coefficient of variation as a measure of sincerity of effort of grip strength, Part I: the statistical principle.

    Science.gov (United States)

    Shechtman, O

    2001-01-01

    The coefficient of variation (CV) is a widely used measure of sincerity of effort of grip strength despite contradictory research findings and lack of empirical support in the literature. The purpose of this study was to investigate whether the CV is an appropriate measure of sincerity of effort. One hundred forty-six uninjured volunteers underwent a series of grip strength tests. The mean, standard deviation (SD), and CV of repeated strength trials were calculated, and paired comparisons were conducted between maximal and submaximal efforts. While the mean of maximal trials was significantly greater, there were no differences in SD between maximal and submaximal trials. Therefore, the increased CV associated with submaximal effort was an artifact of reduced torque rather than an indicator of a true increase in variability. Consequently, the CV is not an appropriate measure of sincerity of effort of grip strength.

  11. Hand Grip Strength and Myocardial Oxygen Consumption Index among Coronary Artery Bypass Grafting Patients

    Directory of Open Access Journals (Sweden)

    Siti Nur Baait Biniti Mohd Sokran

    2015-07-01

    Full Text Available Background: Hand grip strength (HGS is a reliable indicator of peripheral muscle strength. Although, numerous studies have investigated the strength of hand grip; little attention has been given to coronary artery disease (CAD patients, exploring the relationship between HGS and myocardial oxygen consumption (MVO2 index. The current study aimed to evaluate the interaction between HGS and MVO2 index findings before and after cardiac surgery. Methods: Twenty-seven patients with CAD had HGS were assessed using handheld dynamometer. HGS for each hand were documented. MVO2 index was assessed using rate pressure product (RPP, which is the product of the heart rate (HR and systolic blood pressure (SBP. Repeated measures MANOVA were carried out to estimate the interaction between both hands HGS and MVO2 index before and after surgery. Results: There was significant interactions (P<0.001 for both HGS dominant and non-dominant with large effect sizes (HGS dominant×MVO2 index: hp2=0.44; HGS dominant×RPP: hp2=0.49. This signifies that peripheral muscle strength of the upper limb (HGS dominant and non-dominant had different effects on MVO2 index before and after surgery. The interaction graph shows that the increase in MVO2 index after surgery was significantly greater for peripheral muscle strength of the dominant hand when compared to non-dominant. Conclusion: Patients with CAD had interactions between HGS and oxygen consumption before and after surgery. Hence, HGS might be used as a predictor to assess oxygen consumption among cardiac patients.

  12. The effect of vibration exposure during haul truck operation on grip strength, touch sensation, and balance.

    Science.gov (United States)

    Pollard, Jonisha; Porter, William; Mayton, Alan; Xu, Xueyan; Weston, Eric

    2017-01-01

    Falls from mobile equipment are reported at surface mine quarry operations each year in considerable numbers. Research shows that a preponderance of falls occur while getting on/off mobile equipment. Contributing factors to the risk of falls include the usage of ladders, exiting onto a slippery surface, and foot or hand slippage. Balance issues may also contribute to fall risks for mobile equipment operators who are exposed to whole-body vibration (WBV). For this reason, the National Institute for Occupational Safety and Health, Office of Mine Safety and Health Research conducted a study at four participating mine sites with seven haul truck operators. The purpose was to ascertain whether WBV and hand-arm vibration (HAV) exposures for quarry haul truck operators were linked to short-term decreases in performance in relation to postural stability, touch sensation threshold, and grip strength that are of crucial importance when getting on/off the trucks. WBV measures of frequency-weighted RMS accelerations (wRMS) and vibration dose value (VDV), when compared to the ISO/ANSI standards, were mostly below levels identified for the Health Guidance Caution Zone (HGCZ), although there were instances where the levels were within and above the specified Exposure Action Value. Comparably, all mean HAV levels, when compared to the ISO/ANSI standards, were below the HGCZ. For the existing conditions and equipment, no significant correlation could be identified between the WBV, HAV, postural stability, touch sensation threshold, and grip strength measures taken during this study.

  13. Using the coefficient of variation to detect sincerity of effort of grip strength: a literature review.

    Science.gov (United States)

    Shechtman, O

    2000-01-01

    Many clinicians use the coefficient of variation (CV) to assess sincerity of effort, without understanding the premise on which it is based or its physiological and mathematical bases. Clinicians who use computerized evaluation systems that calculate the CV may not even be aware of the formula used to derive it. The wide use of the CV in detecting sincerity of effort of grip strength is puzzling, since it lacks empirical support in the literature. This paper examines the physiological rationale for using measures of variability to detect sincerity of effort, the mathematical basis on which the CV is founded, and the reliability and validity of the CV. The conclusions based on this literature review are that the CV is not an appropriate method for determining whether an effort is sincere and that CV values may be inflated in injured patients with compromised hand strength.

  14. Low serum selenium concentrations are associated with poor grip strength among older women living in the community

    OpenAIRE

    2007-01-01

    Aging is associated with a loss of muscle strength, and, in turn, loss of muscle strength has been associated with increased risk of frailty, disability and mortality. The factors that contribute to loss of muscle strength with aging have not been well characterized. Selenium is important in normal muscle function because of its role in selenoenzymes that protect muscle against oxidative damage. We hypothesized that low serum selenium concentrations were associated with poor grip strength. We...

  15. [Evaluation of grip strength in normal and obese Wistar rats submitted to swimming with overload after median nerve compression].

    Science.gov (United States)

    Coradinia, Josinéia Gresele; Kakihata, Camila Mayumi Martin; Kunz, Regina Inês; Errero, Tatiane Kamada; Bonfleur, Maria Lúcia; Bertolini, Gladson Ricardo Flor

    2015-01-01

    To verify the functionality through muscle grip strength in animals with obesity induced by monosodium glutamate (MSG) and in control animals, which suffered compression of the right median nerve, and treated with swimming with overload. During the first five days of life, neonatal Wistar rats received subcutaneous injections of MSG. The control group received a hypertonic saline solution. Forty-eight rats were divided into six groups: G1 (control); G2 (control + injury); G3 (control + injury + swimming); G4 (obese); G5 (obese + injury); G6 (obese + injury + swimming). The animals in groups G2, G3, G5 and G6 were submitted to compression of the median nerve and G3 and G6 groups were treated, after injury, with swimming exercise with load for three weeks. The swimming exercise had a progressive duration, according to the week, of 20, 30 and 40minutes. Muscle strength was assessed using a grip strength meter preoperatively and on the 3rd, 7th, 14th and 21st days after surgery. The results were expressed and analyzed using descriptive and inferential statistics. When the grip strength was compared among assessments regardless of group, in the second assessment the animals exhibited lower grip strength. G1 and G4 groups had greater grip strength, compared to G2, G3, G4 and G6. The swimming exercise with overload has not been effective in promoting improvement in muscle grip strength after compression injury of the right median nerve in control and in obese-MSG rats. Copyright © 2013 Elsevier Editora Ltda. All rights reserved.

  16. Long-term outcome of muscle strength in ulnar and median nerve injury: Comparing manual muscle strength testing, grip and pinch strength dynamometers and a new intrinsic muscle strength dynamometer

    NARCIS (Netherlands)

    A.R. Schreuders (Ton); M.E. Roebroeck (Marij); J.B. Jaquet (Jean); S.E.R. Hovius (Steven); H.J. Stam (Henk)

    2004-01-01

    textabstractObjective: To compare the outcome of muscle strength with manual muscle strength testing grip and pinch strength measurements and a dynamometer which allows for measurements of the intrinsic muscles of the hand in isolation (the Rotterdam Intrinsic Hand Myometer, RIHM). Methods:

  17. Long-term outcome of muscle strength in ulnar and median nerve injury: Comparing manual muscle strength testing, grip and pinch strength dynamometers and a new intrinsic muscle strength dynamometer

    NARCIS (Netherlands)

    A.R. Schreuders (Ton); M.E. Roebroeck (Marij); J.B. Jaquet (Jean); S.E.R. Hovius (Steven); H.J. Stam (Henk)

    2004-01-01

    textabstractObjective: To compare the outcome of muscle strength with manual muscle strength testing grip and pinch strength measurements and a dynamometer which allows for measurements of the intrinsic muscles of the hand in isolation (the Rotterdam Intrinsic Hand Myometer, RIHM). Methods: Thirty-f

  18. Reliability of the grip strength coefficient of variation for detecting sincerity in normal and blocked median nerve in healthy adults.

    Science.gov (United States)

    Wachter, N J; Mentzel, M; Hütz, R; Gülke, J

    2017-04-01

    In the assessment of hand and upper limb function, detecting sincerity of effort (SOE) for grip strength is of major importance to identifying feigned loss of strength. Measuring maximal grip strength with a dynamometer is very common, often combined with calculating the coefficient of variation (CV), a measure of the variation over the three grip strength trials. Little data is available about the relevance of these measurements in patients with median nerve impairment due to the heterogeneity of patient groups. This study examined the reliability of grip strength tests as well as the CV to detect SOE in healthy subjects. The power distribution of the individual fingers and the thenar was taken into account. To assess reliability, the measurements were performed in subjects with a median nerve block to simulate a nerve injury. The ability of 21 healthy volunteers to exert maximal grip force and to deliberately exert half-maximal force to simulate reduced SOE in a power grip was examined using the Jamar(®) dynamometer. The experiment was performed in a combined setting with and without median nerve block of the same subject. The force at the fingertips of digits 2-5 and at the thenar eminence was measured with a sensor glove with integrated pressure receptors. For each measurement, three trials were recorded subsequently and the mean and CV were calculated. When exerting submaximal force, the subjects reached 50-62% of maximal force, regardless of the median nerve block. The sensor glove revealed a significant reduction of force when exerting submaximal force (P1 sensor) with (P<0.032) and without median nerve block (P<0.017). An increase in CV at submaximal force was found, although it was not significant. SOE can be detected with the CV at the little finger at using a 10% cut-off (sensitivity 0.84 and 0.92 without and with median nerve block, respectively). These findings suggest low reliability of the power grip measurement with the Jamar(®) dynamometer, as

  19. Physical function, grip strength and frailty in people living with HIV in sub-Saharan Africa: systematic review.

    Science.gov (United States)

    Bernard, Charlotte; Dabis, François; de Rekeneire, Nathalie

    2017-05-01

    To present the current knowledge on physical function, grip strength and frailty in HIV-infected patients living in sub-Saharan Africa, where the phenomenon is largely underestimated. A systematic search was conducted on MEDLINE, Scopus and African Index Medicus. We reviewed articles on sub-Saharan African people living with HIV (PLHIV) >18 years old, published until November 2016. Of 537 articles, 12 were conducted in six African countries and included in this review. Five articles reported information on functional limitation and one on disability. Two of these five articles reported functional limitation (low gait speed) in PLHIV. Disability was observed in 27% and 3% of PLHIV living in rural and urban places, respectively. Two of three studies reporting grip strength reported lower grip strength (nearly 4 kg) in PLHIV in comparison with uninfected patients. One study reported that PLHIV were more likely to be frail than HIV-uninfected individuals (19.4% vs. 13.3%), whereas another reported no statistical difference. Decline in physical function, grip strength and frailty are now part of the burden of PLHIV living in SSA countries, but current data are insufficient to characterise the real public health dimension of these impairments. Further studies are needed to depict this major public health challenge. As this is likely to contribute to a significant burden on the African healthcare systems and human resources in the near future, a holistic care approach should be developed to inform guidelines. © 2017 John Wiley & Sons Ltd.

  20. The coefficient of variation as a measure of sincerity of effort of grip strength, Part II: sensitivity and specificity.

    Science.gov (United States)

    Shechtman, O

    2001-01-01

    The coefficient of variation (CV) is commonly used to detect sincerity of effort. The purpose of this study was to examine whether the CV possessed adequate sensitivity and specificity to effectively detect sincerity of effort of grip strength. One hundred forty-six uninjured volunteers underwent a series of grip strength tests. Sensitivity and specificity values were calculated for various CV cut-off values (between 2.5% and 22%) of the static grip test. The receiver operating characteristic (ROC) curves based on these values demonstrated the trade-offs between specificity and sensitivity. For example, the "traditional" 15% cut-off value yielded poor sensitivity (0.55), whereas the 11% cut-off value yielded poor specificity (0.74). Selecting any cut-off value along the continuum did not provide adequate sensitivity or specificity for labeling an effort sincere or insincere. Although the CV differentiated between maximal and submaximal effort, it was not sensitive or specific enough to do so effectively. Thus, the CV should not be used to assess sincerity of effort of grip strength.

  1. Detecting submaximal efforts in grip strength testing with the coefficient of variation.

    Science.gov (United States)

    Robinson, M E; Geisser, M E; Hanson, C S; O'Connor, P D

    1993-03-01

    The use of the coefficient of variation (CV) to determine level of effort in grip strength testing was examined empirically. Twenty-nine asymptomatic subjects participated in two conditions of testing: 100% effort and 50% effort. Order of conditions was counterbalanced and each subject was run in both conditions twice in the same order in order to assess the stability of the method. The number of trials (grasps) per condition was three for a total of 12 grasps for the study. The submaximal (50%) effort condition showed significantly more variability than the maximal effort condition in both sets of conditions (p<.01). Intra-class correlation coefficients were very low for both maximal effort and submaximal efforts (.036 and .025) indicating very low stability for the coefficient of variation. Classification rates were also found to have unacceptably large errors with 69% of the submaximal efforts being classified as maximal with the traditional 15% CV cutoff and 55% misclassification of submaximal efforts with an optimized 11% CV cutoff. It was concluded that the currently practiced method of using a low number of repetitions to calculate the CV may result in very unstable measures. Furthermore the "false negative" rate in using this method is unacceptably high for practical application. The implications of using the method and suggestions for improvement are discussed.

  2. Lipodystrophy and inflammation predict later grip strength in HIV-infected men: the MACS Body Composition substudy.

    Science.gov (United States)

    Crawford, Keith W; Li, Xiuhong; Xu, Xiaoqiang; Abraham, Alison G; Dobs, Adrian S; Margolick, Joseph B; Palella, Frank J; Kingsley, Lawrence A; Witt, Mallory D; Brown, Todd T

    2013-08-01

    Body fat changes in HIV-infected persons are associated with increased systemic inflammation and increased mortality. It is unknown whether lipodystrophy is also associated with declines in physical function. Between 2001 and 2003, 33 HIV-infected men with evidence of lipodystrophy (LIPO⁺), 23 HIV-infected men without lipodystrophy (LIPO⁻), and 33 seronegative men were recruited from the Multicenter AIDS Cohort Study (MACS) for the Body Composition substudy. Visceral adipose tissue (VAT) was assessed by quantitative computed tomography. Lean body mass (LBM) and extremity fat were measured by dual-energy x-ray absorptiometry. Insulin resistance was estimated by Homeostatic Model Assessment (HOMA). Serum interleukin (IL)-6, soluble tumor necrosis factor (TNF)-α receptors I and II (sTNFRI and sTNFRII), and highly sensitive C-reactive protein (hs-CRP) concentrations were quantified from archived serum samples. These measurements were correlated with grip strength measured in 2007 using linear regression. At the substudy visit, the LIPO⁺ group had higher HOMA, sTNFRI, sTNFRII, and IL-6 levels than the LIPO⁻ group. In 2007, the LIPO⁺ group had lower median grip strength than the LIPO⁻ group (34.4 vs. 42.7 kg, p=0.002). Multivariable analysis of HIV⁺ men showed older age, lower LBM, higher sTNFRII concentrations, and LIPO⁺ status [adjusted mean difference -4.9 kg (p=0.045)] at the substudy visit were independently associated with lower subsequent grip strength. Inflammation, lower LBM, and lipodystrophy in HIV-infected men were associated with lower subsequent grip strength. These findings suggest that inflammation may contribute to declines in functional performance, independent of age.

  3. Effect of range of motion and isometric strengthening exercises on grip strength and hand function in rheumatoid arthritis patients

    Directory of Open Access Journals (Sweden)

    Yefta Daniel Bastiana

    2016-04-01

    Full Text Available In previous studies, duration of hand exercises in patients with rheumatoid arthritis (RA had widely varying ranges, from 3 weeks to 4 months. An experimental study was conducted to evaluate the effect of range of motion (ROM and muscle strengthening exercises for 6 weeks on grip strength and hand function in RA patients. Seventeen patients with chronic RA were randomly assigned to a treatment group and a control group. The treatment group (n=8 was given muscle strengthening exercises and heat therapy using paraffin baths 3 times a week at the hospital and ROM exercises once a day at home for 6 weeks. The control group (n=9 was given only paraffin baths 3 times a week. After 6 weeks, there were significant differences in hand function (p=0.003, right and left grip strength (p=0.000 and p=0.001 and ROM in the interventional group only. ROM and isometric strengthening exercises significantly improved grip strength and hand function in patients with RA, while no impact was found when the patients were given paraffin baths only. In view of the small size of the study population, there is a need for further studies with larger populations.

  4. Rapamycin increases grip strength and attenuates age-related decline in maximal running distance in old low capacity runner rats.

    Science.gov (United States)

    Xue, Qian-Li; Yang, Huanle; Li, Hui-Fen; Abadir, Peter M; Burks, Tyesha N; Koch, Lauren G; Britton, Steven L; Carlson, Joshua; Chen, Laura; Walston, Jeremy D; Leng, Sean X

    2016-04-01

    Rapamycin is known to extend lifespan. We conducted a randomized placebo-controlled study of enteric rapamycin-treatment to evaluate its effect on physical function in old low capacity runner (LCR) rats, a rat model selected from diverse genetic background for low intrinsic aerobic exercise capacity without genomic manipulation and characterized by increased complex disease risks and aging phenotypes. The study was performed in 12 male and 16 female LCR rats aged 16-22 months at baseline. The treatment group was fed with rapamycin-containing diet pellets at approximately 2.24mg/kg body weight per day and the placebo group with the same diet without rapamycin for six months. Observation was extended for additional 2 months. Physical function measurements include grip strength measured as maximum tensile force using a rat grip strength meter and maximum running distance (MRD) using rat physical treadmill test. The results showed that rapamycin improved grip strength by 13% (p=.036) and 60% (p=.001) from its baseline in female and male rats, respectively. Rapamycin attenuated MRD decline by 66% (p=.001) and 46% (p=.319) in females and males, respectively. These findings provide initial evidence for beneficial effect of rapamycin on physical functioning in an aging rat model of high disease risks with significant implication in humans.

  5. Modified forelimb grip strength test detects aging-associated physiological decline in skeletal muscle function in male mice

    Science.gov (United States)

    Takeshita, Hikari; Yamamoto, Koichi; Nozato, Satoko; Inagaki, Tadakatsu; Tsuchimochi, Hirotsugu; Shirai, Mikiyasu; Yamamoto, Ryohei; Imaizumi, Yuki; Hongyo, Kazuhiro; Yokoyama, Serina; Takeda, Masao; Oguro, Ryosuke; Takami, Yoichi; Itoh, Norihisa; Takeya, Yasushi; Sugimoto, Ken; Fukada, So-ichiro; Rakugi, Hiromi

    2017-01-01

    The conventional forelimb grip strength test is a widely used method to assess skeletal muscle function in rodents; in this study, we modified this method to improve its variability and consistency. The modified test had lower variability among trials and days than the conventional test in young C57BL6 mice, especially by improving the variabilities in male. The modified test was more sensitive than the conventional test to detect a difference in motor function between female and male mice, or between young and old male mice. When the modified test was performed on male mice during the aging process, reduction of grip strength manifested between 18 and 24 months of age at the group level and at the individual level. The modified test was similar to the conventional test in detecting skeletal muscle dysfunction in young male dystrophic mice. Thus, the modified forelimb grip strength test, with its improved validity and reliability may be an ideal substitute for the conventional method. PMID:28176863

  6. Hand grip strength and chronic obstructive pulmonary disease in Korea: an analysis in KNHANES VI

    Directory of Open Access Journals (Sweden)

    Lee SH

    2017-08-01

    Full Text Available Su Hwan Lee, Soo Jung Kim, Yeji Han, Yon Ju Ryu, Jin Hwa Lee, Jung Hyun Chang Division of Pulmonary and Critical Care Medicine, Department of Internal Medicine, Ewha Medical Research Institute, Ewha Womans University School of Medicine, Seoul, Korea Background: Muscle mass is known to be associated with mortality in elderly adults. Because hand grip strength (HGS is known as a simple assessment tool for muscular strength, many researchers have studied the association between HGS and disease. However, empirical evidence for the relationship between chronic obstructive pulmonary disease (COPD and HGS is still controversial. The aim of this study was to evaluate the association between COPD and HGS, using Korean population data. Methods: This was a population-based cross-sectional study. Data were obtained from the sixth Korean National Health and Nutrition Examination Survey, which was conducted from 2013 to 2015. To reduce the effects of HGS-related factors and potential confounding factors, propensity score matching was used to match subjects with and without COPD. Results: Among 14,930 subjects, 832 were enrolled in each group (non-COPD and COPD after propensity score matching. COPD subjects did not have lower HGS than non-COPD subjects (non-COPD vs COPD, male, 38.0±7.0 vs 38.9±7.0 kg, P=0.044, female, 23.8±4.6 vs 24.2±4.9 kg, P=0.342. Lung function was classified by Global Initiative for Chronic Obstructive Lung Disease stages and was not significantly associated with HGS. For male COPD subjects, there was a significant correlation between HGS and the EuroQol Five-Dimension Questionnaire (EQ5D utility score index, which is an indicator of quality of life that adjusts for age and body mass index (r=0.201, P<0.001. The correlation was absent for female subjects (r=0.098, P=0.170. Conclusion: COPD subjects did not have lower HGS than non-COPD subjects. HGS did not associate with lung function. However, the HGS of male COPD subjects was

  7. IMPACT OF COMBINING MIRROR THERAPY AND HABIT ON HAND GRIP STRENGTH IN CHILDREN WITH HEMIPARESIS

    Directory of Open Access Journals (Sweden)

    Asmaa A. Abo Nour

    2016-08-01

    Full Text Available Background: hemiparetic children usually tend to avoid the use of their impaired arm and are remarkably tend to perform inherently bimanual tasks of daily living with the less impaired arm only rather than with both arms. In fact, these children actually may have never learned to use their impaired arm for certain motor tasks or may only use it in the simplest manner, so the purpose of the study was to determine the impact of combining HABIT and mirror therapy on hand grip in hemiparetic children. Methods: A total of 30 hemiparetic children divided randomly into two groups (A and B of equal number, (N of each =15. Eligibility criteria to our study were age ranged from 4-8 years, ability to score more than 50 % of grasps and associated domains of quality of upper extremity skills test (QUEST and grade 2 in manual ability classification system (MACS, assessment done by baseline hand held dynamometer for hand palmar & pinch grasp strength (in pounds at start (0 week, reassessed at 4 & 8 weeks. The treatment protocol for two groups include: 2 months total time, 3 sessions\\ week, 1.5 hour\\session. Children in study group (A received selected occupational therapy program with modified mirror apparatus while children in control group (B Children received the same occupational therapy program as in study group but without modified mirror apparatus. Results: there is significant improvement in both groups when comparing the pre and post I & II treatment mean values. However comparing the post treatment results of both groups were statistically non-significant. Conclusion: This study confirmed that combining mirror therapy and HABIT is effective in improving hand function.

  8. Effect of anaemia on hand grip strength, walking speed, functionality and 1 year mortality in older hospitalized patients.

    Science.gov (United States)

    Joosten, Etienne; Detroyer, Elke; Milisen, Koen

    2016-08-19

    Anaemia is a common problem in hospitalized older patients and is recognized as a risk factor for a significant number of adverse outcomes. Data of the effect of anaemia on functional status during hospitalization and mortality after discharge are limited. Aim of the study is to examine whether there is an association between anaemia, hand grip strength, gait speed and basic activities of daily living (ADL) during hospitalization and mortality 1 year after discharge in geriatric patients. In a prospective study, data on age, sex, body mass index, Mini-Mental State Examination (MMSE), main clinical diagnosis, number of comorbidities, hand grip strength, gait speed, ADL, haemoglobin, C-reactive protein and estimated Glomerular filtration ratio (eGFR) were recorded in 220 older patients, admitted to the acute geriatric ward of a university hospital. Anaemia was defined as a haemoglobin level anaemia (haemoglobin between 10 and 12 g/dL for women and 10 and 13 g/dL for men). Gait speed (in meters per second) was calculated after a 4.5 m walk and hand grip strength (in kilogram) was assessed with a hydraulic hand dynamometer. Functionality was assessed in the six basic activities of daily living. Information about the vital status was obtained 1 year after discharge with a telephone call. Analysis of covariance (ANCOVA) was used to examine the effect of the anaemia status on the walking speed, hand grip strength and premorbid ADL index and logistic regression analysis was used to examine whether anaemia could be identified as risk factors for mortality 12 months after discharge. Overall, 106 (48 %) patients had anaemia. Hand-grip strength, gait speed and ADL score were not significantly different between anaemic and non-anaemic hospitalized geriatric patients. After adjustment for age, sex, body mass index, eGFR, MMSE, number of comorbidities and main clinical diagnosis, the means for hand-grip strength were 17.3, 19.9 and 19.1 kg (p = 0.38); for gait speed 0

  9. [Gait speed, grip strength and self-rated health among the elderly: data from the FIBRA Campinas network, São Paulo, Brazil].

    Science.gov (United States)

    Bez, Joelita Pessoa de Oliveira; Neri, Anita Liberalesso

    2014-08-01

    The article seeks to investigate patterns of performance and relationships between grip strength, gait speed and self-rated health, and investigate the relationships between them, considering the variables of gender, age and family income. This was conducted in a probabilistic sample of community-dwelling elderly aged 65 and over, members of a population study on frailty. A total of 689 elderly people without cognitive deficit suggestive of dementia underwent tests of gait speed and grip strength. Comparisons between groups were based on low, medium and high speed and strength. Self-related health was assessed using a 5-point scale. The males and the younger elderly individuals scored significantly higher on grip strength and gait speed than the female and oldest did; the richest scored higher than the poorest on grip strength and gait speed; females and men aged over 80 had weaker grip strength and lower gait speed; slow gait speed and low income arose as risk factors for a worse health evaluation. Lower muscular strength affects the self-rated assessment of health because it results in a reduction in functional capacity, especially in the presence of poverty and a lack of compensatory factors.

  10. Sex Differences in the Level and Rate of Change of Physical Function and Grip Strength in the Danish 1905-Cohort Study

    DEFF Research Database (Denmark)

    Oksuzyan, Anna; Maier, Heiner; McGue, Matt;

    2010-01-01

    OBJECTIVE: The study was conducted to examine sex differences in the initial level and rate of change in physical function and grip strength. METHOD: The baseline survey included 2,262 Danes born in 1905 and alive in 1998 and followed-up in 2000, 2003, and 2005. Hence, the authors fully used...... with intercepts and slopes. DISCUSSION: The Danish data suggested that the longest-living individuals have higher initial levels of strength score and grip strength and smaller rate of change. The data further suggested that the initial level of strength score and grip strength was more predictive of mortality...... than the rate of change was, and the predictive effects were similar in men and women....

  11. Performance of repetitive tasks induces decreased grip strength and increased fibrogenic proteins in skeletal muscle: role of force and inflammation.

    Directory of Open Access Journals (Sweden)

    Samir M Abdelmagid

    Full Text Available BACKGROUND: This study elucidates exposure-response relationships between performance of repetitive tasks, grip strength declines, and fibrogenic-related protein changes in muscles, and their link to inflammation. Specifically, we examined forearm flexor digitorum muscles for changes in connective tissue growth factor (CTGF; a matrix protein associated with fibrosis, collagen type I (Col1; a matrix component, and transforming growth factor beta 1 (TGFB1; an upstream modulator of CTGF and collagen, in rats performing one of two repetitive tasks, with or without anti-inflammatory drugs. METHODOLOGY/RESULTS: To examine the roles of force versus repetition, rats performed either a high repetition negligible force food retrieval task (HRNF, or a high repetition high force handle-pulling task (HRHF, for up to 9 weeks, with results compared to trained only (TR-NF or TR-HF and normal control rats. Grip strength declined with both tasks, with the greatest declines in 9-week HRHF rats. Quantitative PCR (qPCR analyses of HRNF muscles showed increased expression of Col1 in weeks 3-9, and CTGF in weeks 6 and 9. Immunohistochemistry confirmed PCR results, and also showed greater increases of CTGF and collagen matrix in 9-week HRHF rats than 9-week HRNF rats. ELISA, and immunohistochemistry revealed greater increases of TGFB1 in TR-HF and 6-week HRHF, compared to 6-week HRNF rats. To examine the role of inflammation, results from 6-week HRHF rats were compared to rats receiving ibuprofen or anti-TNF-α treatment in HRHF weeks 4-6. Both treatments attenuated HRHF-induced increases in CTGF and fibrosis by 6 weeks of task performance. Ibuprofen attenuated TGFB1 increases and grip strength declines, matching our prior results with anti-TNFα. CONCLUSIONS/SIGNIFICANCE: Performance of highly repetitive tasks was associated with force-dependent declines in grip strength and increased fibrogenic-related proteins in flexor digitorum muscles. These changes were

  12. Grip Strength Decline and Its Determinants in the Very Old: Longitudinal Findings from the Newcastle 85+ Study

    Science.gov (United States)

    Davies, Karen; Jagger, Carol; Kirkwood, Thomas B. L.; Syddall, Holly E.; Sayer, Avan A.

    2016-01-01

    Background Weak grip strength (GS) is a key component of sarcopenia and frailty and a powerful predictor of mortality, morbidity and disability. Despite increasing interest in understanding GS across the lifespan, little is known about GS decline in the very old (aged ≥85). We examined trajectories of GS in very old adults and identified the determinants. Methods GS (kg) was measured four times over 5 years in 319 men and 526 women participating in the Newcastle 85+ Study. A weak GS sub-cohort was identified as having strength of ≤27 kg (men), and ≤16 kg (women) at baseline and follow-up. Mixed models were used to establish trajectories of GS and associated factors in all participants, men and women, and in those with weak GS. Results Men’s mean grip strength was 24.42 (SD = 6.77) kg, and women’s 13.23 (4.42) kg (p<0.001) at baseline, with mean absolute change of -5.27 (4.90) kg and -3.14 (3.41), respectively (p<0.001) by 5-year follow-up. In the time-only mixed model, men experienced linear annual decline in GS of -1.13 (0.8) kg (β (SE), p<0.001), whilst women’s decline although slower, accelerated by -0.06 (0.02) kg (p = 0.01) over time. In the saturated model, higher baseline physical activity, height, fat-free mass, better self-rated health, and not having arthritis in hand(s) were associated with stronger GS initially in both sexes. Annual GS decline in men and participants with weak GS who were highly physically active was slower by 0.95 and 0.52 kg, respectively compared with inactive counterparts. Conclusion Grip strength decline in the very old followed linear (men) and curvilinear (women) trends. High levels of physical activity were protective of GS loss in men (but not in women) and in those with weak GS. Thus maintaining muscle strength in later life is important to reduce the morbidity and mortality in the very old. PMID:27637107

  13. IMPACT OF COMBINING MIRROR THERAPY AND HABIT ON HAND GRIP STRENGTH IN CHILDREN WITH HEMIPARESIS

    OpenAIRE

    Asmaa A. Abo Nour; Saleh, Muhammad G.; Emam H. Elnagmy

    2016-01-01

    Background: hemiparetic children usually tend to avoid the use of their impaired arm and are remarkably tend to perform inherently bimanual tasks of daily living with the less impaired arm only rather than with both arms. In fact, these children actually may have never learned to use their impaired arm for certain motor tasks or may only use it in the simplest manner, so the purpose of the study was to determine the impact of combining HABIT and mirror therapy on hand grip in hemiparetic chil...

  14. A COMPARATIVE STUDY TO FIND OUT IMMEDIATE EFFECTIVENESS OF MOVEMENT WITH MOBILIZATION VERSUS ELBOW ORTHOSIS ON PAIN AND GRIP STRENGTH IN LATERAL EPICONDYLITIS IN HOUSEWIVES

    Directory of Open Access Journals (Sweden)

    Trishna Kakati

    2015-12-01

    Full Text Available Background: There are various studies using Mulligan’s MWM with or without combining with electrotherapy modalities and proved the efficacy of the technique in immediately decreasing pain and improving grip strength in patients with lateral epicondylitis. Orthotic as a treatment is also proved to be beneficial in decreasing pain and improving grip strength. There is evidence that housewives are prone to develop lateral epicondylitis due to their routine household work. But there is lack of evidence which compare initial effects of MWM and orthosis in housewives bringing up better outcome measures. The purpose of this study is to compare the initial effectiveness of Mulligan’s MWM and elbow orthosis on pain and grip strength in housewives with lateral epicondylitis. The aim of the study is to evaluate the effectiveness of Mulligan’s MWM technique versus counterforce elbow orthosis in immediately reducing pain and improving grip strength in lateral epicondylitis in housewives. Methodos: All subjects underwent a pre-treatment examination to assess pain and pain free hand grip strength with the help of outcome measures. Subjects were randomly assigned into two groups, A and B respectively; having 25 subjects in each group. Group A was treated with one session of Mulligan’s MWM technique. Group B was treated with Counterforce elbow strap orthosis. Data was assessed pre-treatment and immediately after treatment. Visual Analogue Scale (VAS and hand grip on Hand Grip Dynamometer (HGD were used as outcome measures. Results: Independent t-test was performed to see the effectiveness between Mulligan’s MWM and elbow orthosis. For VAS, t = - 2.243 which is significant at 5% level of significance. It has been inferred that VAS decreases more when Mulligan’s MWM was applied. For HGD, t = 0.878 which is not significant implying that increase in HGD do not differ remarkably for the two treatments. Conclusion: It has been recorded from the study that

  15. Laterality and grip strength influence hand bone micro-architecture in modern humans, an HRpQCT study.

    Science.gov (United States)

    Reina, Nicolas; Cavaignac, Etienne; Trousdale, William H; Laffosse, Jean-Michel; Braga, José

    2017-06-01

    It is widely hypothesized that mechanical loading, specifically repetitive low-intensity tasks, influences the inner structure of cancellous bone. As such, there is likely a relationship between handedness and bone morphology. The aim of this study is to determine patterns in trabecular bone between dominant and non-dominant hands in modern humans. Seventeen healthy patients between 22 and 32 years old were included in the study. Radial carpal bones (lunate, capitate, scaphoid, trapezium, trapezoid, 1st, 2nd and 3rd metacarpals) were analyzed with high-resolution micro-computed tomography. Additionally, crush and pinch grip were recorded. Factorial analysis indicated that bone volume ratio, trabeculae number (Tb.N), bone surface to volume ratio (BS.BV), body weight, stature and crush grip were all positively correlated with principal components 1 and 2 explaining 78.7% of the variance. Volumetric and trabecular endostructural parameters (BV/TV, BS/BV or Tb.Th, Tb.N) explain the observed inter-individual variability better than anthropometric or clinical parameters. Factors analysis regressions showed correlations between these parameters and the dominant side for crush strength for the lunate (r(2) = 0.640, P modern human wrist. © 2017 Anatomical Society.

  16. Adherence to a standardized protocol for measuring grip strength and appropriate cut-off values in adults over 65 years with sarcopenia: a systematic review protocol.

    Science.gov (United States)

    Fox, Benjamin; Henwood, Tim; Schaap, Laura; Bruyère, Olivier; Reginster, Jean-Yves; Beaudart, Charlotte; Buckinx, Fanny; Roberts, Helen; Cooper, Cyrus; Cherubini, Antonio; dellʼAquilla, Giuseppina; Maggio, Marcello; Volpato, Stefano

    2015-10-01

    The objective of this review is to examine the use of grip strength analysis in well and unwell populations in adults 65 years and over as a tool to establish muscle strength in sarcopenia.More specifically, the main review question is:1. What protocol, if any, is most commonly used among older adults with sarcopenia and does this match the standardized protocol suggested in 2011 by Roberts et al.1?Secondary review questions are:2. What are the reported cut-off values being used to determine sarcopenia in older adults, with consideration for ethnic and gender variability?3. Is grip strength, as a tool to measure muscle strength, suitable for people with common comorbidities and geriatric syndromes, such as osteoarthritis, often associated with sarcopenia? Sarcopenia, a commonly used concept in geriatrics and gerontology, is characterized by a loss of muscle mass, muscle strength and/or physical functioning. Prevalence rates vary between 1-39% in community dwelling older populations and 14-33% in long-term care populations. Several epidemiological studies have shown the association of sarcopenia with adverse health outcomes such as falls, disability, hospitalization and mortality. Originally, sarcopenia refers to the loss of muscle mass with aging, which was later complemented with loss of muscle strength and physical functioning.In 2010, the European Working Group on Sarcopenia in Older People (EWGSOP) reported a consensus definition of sarcopenia, which included measurement of low muscle mass and low muscle function (strength or physical performance). This consensus definition can be used to identify sarcopenia patients in clinical practice and to select individuals for clinical trials. Well-designed clinical trials could ultimately lead to effective treatment and prevention strategies for sarcopenia. Since the publication of the consensus report, many studies have adopted this definition, which could potentially lead to better comparison of results between

  17. Description of Primary Education 1st Grade Students' Forms of Holding a Pencil as well as Their Grip and Compression Strengths

    Science.gov (United States)

    Temur, Turan

    2011-01-01

    This study aimed to examine how first grade students in primary education held and gripped a pencil and their compressive strength using a descriptive research method. The participants of the research comprises first grade students attending a private school in the city center of Ankara (n=79). All of the four different sections in this private…

  18. Serotonin and Histamine Therapy Increases Tetanic Forces of Myoblasts, Reduces Muscle Injury, and Improves Grip Strength Performance of Dmdmdx Mice

    Directory of Open Access Journals (Sweden)

    Volkan Gurel

    2015-11-01

    Full Text Available Duchenne muscular dystrophy (DMD is a recessive X-linked fatal disorder caused by a mutation in the dystrophin gene. Although several therapeutic approaches have been studied, none has led to substantial long-term effects in patients. The aim of this study was to test a serotonin and histamine (S&H combination on human skeletal myoblasts and Dmdmdx mice for its effects on muscle strength and injury. Normal human bioartificial muscles (BAMs were treated, and muscle tetanic forces and muscle injury tests were performed using the MyoForce Analysis System. Dmdmdx mice, the murine model of DMD, were administered serotonin, histamine, or S&H combination twice daily for 6 weeks, and functional performance tests were conducted once a week. The S&H combination treatment caused significant increases in tetanic forces at all time points and concentrations tested as compared to the saline controls. Dose response of the BAMs to the treatment demonstrated a significant increase in force generation at all concentrations compared to the controls after 3 to 4 days of drug treatment. The highest 3 concentrations had a significant effect on lowering contractile-induced injury as measured by a reduction in the release of adenylate kinase. Histamine-only and S&H treatments improved grip strength of Dmdmdx mice, whereas serotonin-only treatment resulted in no significant improvement in muscle strength. The results of this study indicate that S&H therapy might be a promising new strategy for muscular dystrophies and that the mechanism should be further investigated.

  19. Degree, but not direction of grip strength asymmetries, is related to depression and anxiety in an elderly population.

    Science.gov (United States)

    Yu, Junhong; Rawtaer, Iris; Mahendran, Rathi; Kua, Ee-Heok; Feng, Lei

    2017-05-01

    Despite the abundance of studies on asymmetries in manual laterality, a marker for atypical brain lateralization in depression and anxiety, findings in this area are mixed. Traditionally, research have looked at individual differences in depression and anxiety as a function of the direction of asymmetry. However, recent research has emphasized on studying the degree of asymmetry in addition to its direction. To these ends, the present study aims to unravel the associations between the degree and direction of manual lateralization, and depression/anxiety. Cognitively healthy elderlies (N = 326, 91 males, Mage = 68) were administered grip strength assessments on both hands and self-report measures of depression and anxiety. Partial correlation analyses controlling for age, education and sex revealed significant positive associations between degree of lateralization and anxiety in the overall sample and among right-dominant participants, as well as a significant positive relationship between degree of lateralization and depression among right-dominant participants. None of the correlations involving the direction of lateralization yielded significance, neither was there significant differences between left- and right-dominant participants on depression and anxiety scores. These findings suggest that the degree of manual lateralization, but not direction, is related to depression and anxiety at least among right-dominant individuals.

  20. Sustained effect of resistance training on blood pressure and hand grip strength following a detraining period in elderly hypertensive women: a pilot study

    Science.gov (United States)

    Nascimento, Dahan da Cunha; Tibana, Ramires Alsamir; Benik, Franklin M; Fontana, Keila Elizabeth; Neto, Frederico Ribeiro; de Santana, Frederico Santos; Santos-Neto, Leopoldo; Silva, Renato André Sousa; Silva, Alessandro Oliveira; Farias, Darlan Lopes; Balsamo, Sandor; Prestes, Jonato

    2014-01-01

    Introduction Hypertension is the most prevalent modifiable risk factor with a high prevalence among older adults. Exercise is a nonpharmacological treatment shown to benefit all patients with hypertension. Objective This study examined the effects of a 14-week moderate intensity resistance training program (RT) on the maintenance of blood pressure and hand grip strength during an extended detraining period in elderly hypertensive women. Methods Twelve hypertensive sedentary elderly women completed 14 weeks of whole body RT at a moderate perceived exertion following a detraining period of 14 weeks. Results Following the training period, participants demonstrated an increase in absolute hand grip strength (P=0.001), relative hand grip strength (P=0.032) and a decrease of systolic (P=0.001), diastolic (P=0.008), and mean blood pressure (P=0.002) when compared to pre-exercise values. In addition, these effects were sustained after 14 weeks of detraining. Conclusion Resistance training may be a valuable method to improve muscular strength and blood pressure in elderly people with benefits being maintained up to 14 weeks following training cessation. PMID:24477221

  1. Comparison of hand grip strength and upper limb pressure pain threshold between older adults with or without non-specific shoulder pain

    Science.gov (United States)

    2017-01-01

    Background There is a high prevalence of non-specific shoulder pain associated with upper limb functional limitations in older adults. The purpose of this study was to determine the minimal clinically important differences (MCID) of grip strength and pressure pain threshold (PPT) in the upper limb between older adults with or without non-specific shoulder pain. Methods A case-control study was carried out following the Strengthening the Reporting of Observational Studies in Epidemiology (STROBE) criteria. A sample of 132 shoulders (mean ± SD years) with (n = 66; 76.04 ± 7.58) and without (n = 66; 75.05 ± 6.26) non-specific pain were recruited. The grip strength and PPT of the anterior deltoid and extensor carpi radialis brevis (ECRB) muscles were assessed. Results There were statistically significant differences (mean ± SD; P-value) for anterior deltoid PPT (2.51 ± 0.69 vs 3.68 ± 0.65, kg/cm2; P PPT (2.20 ± 0.60 vs 3.35 ± 0.38 kg/cm2; P PPT, ECRB PPT and grip strength, respectively, to assess the upper limb of older adults with non-specific shoulder pain after treatment. In addition, univariate and multivariate (linear regression and regression trees) analyses may be used to consider age distribution, sex, pain intensity, grip strength and PPT in older adults including clinical and epidemiological studies with non-specific shoulder pain. PMID:28289561

  2. Short Physical Performance Battery, usual gait speed, grip strength and Vulnerable Elders Survey each predict functional decline among older women with breast cancer.

    Science.gov (United States)

    Owusu, Cynthia; Margevicius, Seunghee; Schluchter, Mark; Koroukian, Siran M; Berger, Nathan A

    2017-09-01

    To determine the ability of three performance-based measures [Short Physical Performance Battery (SPPB), gait speed, and Grip Strength] and a self-report measure [Vulnerable Elders Survey (VES-13)] to predict functional decline among older women with breast cancer. Longitudinal data from a study of women ≥65years, with newly diagnosed stages I-III breast cancer, recruited from ambulatory oncology clinics between July 2010 and April 2014, was used. The primary outcome was functional decline, Yes or No, defined as a decrease in ≥1-point from baseline to 12months, on Activities of Daily Living Scales. Multivariable logistic regression and receiver operator curve analyses were conducted. Among 123 participants 18 (15%) developed functional decline. The predictive abilities for measures were: SPPB [Adjusted odds ratio (AOR)=1.65 per unit decrease in scores, 95% confidence interval (CI)=1.33-2.05; area under the receiver operator curve (AUC)=0.93; sensitivity=94%, specificity=80%]; gait speed (AOR=1.76 per unit increase in usual walking time, CI=1.29-2.41; AUC=0.93; sensitivity=87%, specificity=79%); VES-13 (AOR=1.64 per unit increase in scores, CI=1.31-2.05; AUC=0.87; sensitivity=83%, specificity=84%); and grip strength: (AOR=1.18 per unit decrease in grip strength, CI=1.06-1.30; AUC=0.80; sensitivity=67%, specificity=77%). SPPB, gait speed, grip strength and VES-13 all demonstrated excellent predictive abilities for functional decline. Larger studies are warranted to confirm the utility of these measures for identifying older adults with cancer at increased risk for functional decline, who may then be targeted for studies to explore the effects of interventions to improve function. Copyright © 2017 Elsevier Inc. All rights reserved.

  3. Changes in pain, dysfunction, and grip strength of patients with acute lateral epicondylitis caused by frequency of physical therapy: a randomized controlled trial.

    Science.gov (United States)

    Lee, Soyoung; Ko, Youngjun; Lee, Wanhee

    2014-07-01

    [Purpose] The purpose of this study was to investigate the changes in pain, dysfunction, and grip strength of patients with acute lateral epicondylitis and to suggest the appropriate treatment frequency and period. [Subjects] The subjects were divided into three: 2 days per week group (n=12), 3 days per week group (n=15), and 6 days per week group (n=13). [Methods] All groups received conventional physical therapy for 40 minutes and therapeutic exercises for 20 minutes per session during 6 weeks. The outcome measurements were the visual analogue scale (VAS), Patient-Rated Tennis Elbow Evaluation (PRTEE), and grip strength. [Results] The results of this study were as follows: at 3 weeks, there were no significant differences in VAS and PRTEE in the 3 groups, but at 6 weeks, 6 days per week group significantly decreased these two outcomes. Grip strength was significantly increased in 3 and 6 days per week groups at 6 weeks. [Conclusion] In conclusion, physical therapy is needed 3 days per week for 3 weeks in patients with acute lateral epicondylitis. After 3 weeks, 6 days per week is the most effective treatment frequency.

  4. Comparison of hand grip strength and upper limb pressure pain threshold between older adults with or without non-specific shoulder pain

    Directory of Open Access Journals (Sweden)

    Cesar Calvo Lobo

    2017-02-01

    Full Text Available Background There is a high prevalence of non-specific shoulder pain associated with upper limb functional limitations in older adults. The purpose of this study was to determine the minimal clinically important differences (MCID of grip strength and pressure pain threshold (PPT in the upper limb between older adults with or without non-specific shoulder pain. Methods A case-control study was carried out following the Strengthening the Reporting of Observational Studies in Epidemiology (STROBE criteria. A sample of 132 shoulders (mean ± SD years with (n = 66; 76.04 ± 7.58 and without (n = 66; 75.05 ± 6.26 non-specific pain were recruited. The grip strength and PPT of the anterior deltoid and extensor carpi radialis brevis (ECRB muscles were assessed. Results There were statistically significant differences (mean ± SD; P-value for anterior deltoid PPT (2.51 ± 0.69 vs 3.68 ± 0.65, kg/cm2; P < .001, ECRB PPT (2.20 ± 0.60 vs 3.35 ± 0.38 kg/cm2; P < .001 and grip strength (20.78 ± 10.94 vs 24.63 ± 9.38 kg; P = .032 between shoulders with and without non-specific pain, respectively. Discussion The MCID of 1.17 kg/cm2, 1.15 kg/cm2 and 3.84 kg were proposed for anterior deltoid PPT, ECRB PPT and grip strength, respectively, to assess the upper limb of older adults with non-specific shoulder pain after treatment. In addition, univariate and multivariate (linear regression and regression trees analyses may be used to consider age distribution, sex, pain intensity, grip strength and PPT in older adults including clinical and epidemiological studies with non-specific shoulder pain.

  5. GRIPS Plan

    Energy Technology Data Exchange (ETDEWEB)

    1978-07-31

    The GRIPS (Geothermal Resources Impact Projection Study) Commission was established by a Joint Powers Agreement between the California Counties of Lake, Mendocino, Napa, and Sonoma. The objectives of GRIPS are primarily to develop and use a cooperative environmental data collection and use system including natural, social, and economic considerations to facilitate their independent decisions and those of State and Federal agencies related to the environmental effects of geothermal development. This GRIPS Plan was prepared from a wide range of studies, workshops, and staff analyses. The plan is presented in four parts: summary and introduction; environmental data status report; planned programs; and budget. (MHR)

  6. GRIPS bibliography

    Energy Technology Data Exchange (ETDEWEB)

    1978-07-31

    This GRIPS (Geothermal Resources Impact Project Study) contains over 1700 references on a wide variety of subjects dealing directly or indirectly with geothermal development at the Geysers/Calistoga KGRA. (MHR)

  7. Evaluation of pliers' grip spans in the maximum gripping task and sub-maximum cutting task.

    Science.gov (United States)

    Kim, Dae-Min; Kong, Yong-Ku

    2016-12-01

    A total of 25 males participated to investigate the effects of the grip spans of pliers on the total grip force, individual finger forces and muscle activities in the maximum gripping task and wire-cutting tasks. In the maximum gripping task, results showed that the 50-mm grip span had significantly higher total grip strength than the other grip spans. In the cutting task, the 50-mm grip span also showed significantly higher grip strength than the 65-mm and 80-mm grip spans, whereas the muscle activities showed a higher value at 80-mm grip span. The ratios of cutting force to maximum grip strength were also investigated. Ratios of 30.3%, 31.3% and 41.3% were obtained by grip spans of 50-mm, 65-mm, and 80-mm, respectively. Thus, the 50-mm grip span for pliers might be recommended to provide maximum exertion in gripping tasks, as well as lower maximum-cutting force ratios in the cutting tasks.

  8. Short-Term Effects of Whole-Body Vibration Combined with Task-Related Training on Upper Extremity Function, Spasticity, and Grip Strength in Subjects with Poststroke Hemiplegia: A Pilot Randomized Controlled Trial.

    Science.gov (United States)

    Lee, Jung-Sun; Kim, Chang-Yong; Kim, Hyeong-Dong

    2016-08-01

    The aim of this study was to determine the effect of whole-body vibration training combined with task-related training on arm function, spasticity, and grip strength in subjects with poststroke hemiplegia. Forty-five subjects with poststroke were randomly allocated to 3 groups, each with 15 subjects as follows: control group, whole-body vibration group, and whole-body vibration plus task-related training group. Outcome was evaluated by clinical evaluation and measurements of the grip strength before and 4 weeks after intervention. Our results show that there was a significantly greater increase in the Fugl-Meyer scale, maximal grip strength of the affected hand, and grip strength normalized to the less affected hand in subjects undergoing the whole-body vibration training compared with the control group after the test. Furthermore, there was a significantly greater increase in the Wolf motor function test and a decrease in the modified Ashworth spasticity total scores in subjects who underwent whole-body vibration plus task-related training compared with those in the other 2 groups after the test. The findings indicate that the use of whole-body vibration training combined with task-related training has more benefits on the improvement of arm function, spasticity, and maximal grip strength than conventional upper limb training alone or with whole-body vibration in people with poststroke hemiplegia.

  9. Sustained effect of resistance training on blood pressure and hand grip strength following a detraining period in elderly hypertensive women: a pilot study

    Directory of Open Access Journals (Sweden)

    Nascimento D da C

    2014-01-01

    Full Text Available Dahan da Cunha Nascimento,1,5,8 Ramires Alsamir Tibana,1,8 Franklin M Benik,2 Keila Elizabeth Fontana,3 Frederico Ribeiro Neto,8 Frederico Santos de Santana,5,8 Leopoldo Santos-Neto,4 Renato André Sousa Silva,1,5,6 Alessandro Oliveira Silva,1,7 Darlan Lopes Farias,1,7 Sandor Balsamo,4,5,8 Jonato Prestes1 1Postgraduate Program in Physical Education, Catholic University of Brasilia, Brasilia, Brazil; 2Department of Kinesiology and Sports Studies Graduate Program, Eastern Illinois University, Charleston, IL, USA; 3Faculty of Physical Education, University of Brasilia, Brasilia, Brazil; 4Graduate Program in Medical Sciences of the University of Brasilia, School of Medicine and Rheumatology Service, University Hospital of Brasilia (HUB, Brasilia, Brazil; 5Department of Physical Education, University Center Euro American University Center, Brasilia, Brazil; 6Center of Excellence in Medicine of Exercise (CEMEx, Brasilia, Brazil; 7Center University of Brasilia (UNICEUB, Brasilia, Brazil; 8Strength Training and Health Research Group (GEPEEFS, Brasilia, Brazil Introduction: Hypertension is the most prevalent modifiable risk factor with a high prevalence among older adults. Exercise is a nonpharmacological treatment shown to benefit all patients with hypertension. Objective: This study examined the effects of a 14-week moderate intensity resistance training program (RT on the maintenance of blood pressure and hand grip strength during an extended detraining period in elderly hypertensive women. Methods: Twelve hypertensive sedentary elderly women completed 14 weeks of whole body RT at a moderate perceived exertion following a detraining period of 14 weeks. Results: Following the training period, participants demonstrated an increase in absolute hand grip strength (P=0.001, relative hand grip strength (P=0.032 and a decrease of systolic (P=0.001, diastolic (P=0.008, and mean blood pressure (P=0.002 when compared to pre-exercise values. In addition, these

  10. Vitamin D Receptor Ablation and Vitamin D Deficiency Result in Reduced Grip Strength, Altered Muscle Fibers, and Increased Myostatin in Mice.

    Science.gov (United States)

    Girgis, Christian M; Cha, Kuan Minn; Houweling, Peter J; Rao, Renuka; Mokbel, Nancy; Lin, Mike; Clifton-Bligh, Roderick J; Gunton, Jenny E

    2015-12-01

    Vitamin D deficiency is associated with muscle weakness, pain, and atrophy. Serum vitamin D predicts muscle strength and age-related muscle changes. However, precise mechanisms by which vitamin D affects skeletal muscle are unclear. To address this question, this study characterizes the muscle phenotype and gene expression of mice with deletion of vitamin D receptor (VDRKO) or diet-induced vitamin D deficiency. VDRKO and vitamin D-deficient mice had significantly weaker grip strength than their controls. Weakness progressed with age and duration of vitamin D deficiency, respectively. Histological assessment showed that VDRKO mice had muscle fibers that were significantly smaller in size and displayed hyper-nuclearity. Real-time PCR also indicated muscle developmental changes in VDRKO mice with dysregulation of myogenic regulatory factors (MRFs) and increased myostatin in quadriceps muscle (>2-fold). Vitamin D-deficient mice also showed increases in myostatin and the atrophy marker E3-ubiqutin ligase MuRF1. As a potential explanation for grip strength weakness, both groups of mice had down-regulation of genes encoding calcium-handling and sarco-endoplasmic reticulum calcium transport ATPase (Serca) channels. This is the first report of reduced strength, morphological, and gene expression changes in VDRKO and vitamin D-deficient mice where confounding by calcium, magnesium, and phosphate have been excluded by direct testing. Although suggested in earlier in vitro work, this study is the first to report an in vivo association between vitamin D, myostatin, and the regulation of muscle mass. These findings support a direct role for vitamin D in muscle function and corroborate earlier work on the presence of VDR in this tissue.

  11. Comparison of pressure pain threshold, grip strength,dexterity and touch pressure of dominant and non-dominant hands within and between right-and left-handed subjects.

    Science.gov (United States)

    Ozcan, Ayse; Tulum, Zeliha; Pinar, Lamia; Başkurt, Ferdi

    2004-12-01

    This study was done to evaluate differences in pressure pain threshold, grip strength, manual dexterity and touch pressure threshold in the dominant and non-dominant hands of right- and left-handed subjects, and to compare findings within and between these groups. Thirty-nine right-handed and twenty-one left-handed subjects participated in the study. Pressure pain threshold was assessed using a dolorimeter, grip strength was assessed with a hand-grip dynamometer, manual dexterity was evaluated using the VALPAR Component Work Sample-4 system, and touch pressure threshold was determined using Semmes Weinstein monofilaments. Results for the dominant and non-dominant hands were compared within and between the groups. In the right-handed subjects, the dominant hand was significantly faster with the VALPAR Component Work Sample-4, showed significantly greater grip strength, and had a significantly higher pressure pain threshold than the non-dominant hand. The corresponding results for the two hands were similar in the left-handed subjects. The study revealed asymmetrical manual performance in grip strength, manual dexterity and pressure pain threshold in right-handed subjects, but no such asymmetries in left-handed subjects.

  12. Grip strength measurements at two different wrist extension positions in chronic lateral epicondylitis-comparison of involved vs. uninvolved side in athletes and non athletes: a case-control study

    Directory of Open Access Journals (Sweden)

    Bhargava Arti S

    2010-09-01

    Full Text Available Abstract Background Lateral epicondylitis is a common sports injury of the elbow caused due to altered muscle activation during repetitive wrist extension in many athletic and non-athletic endeavours. The amount of muscle activity and timing of contraction eventually is directly dependent upon joint position during the activity. The purpose of our study was to compare the grip strength in athletes with lateral epicondylalgia in two different wrist extension positions and compare them between involved and uninvolved sides of athletes and non-athletes. Methods An assessor-blinded case-control study of eight athletes and twenty-two non-athletes was done. The grip strength was measured using JAMAR® hand dynamometer in kilograms-force at 15 degrees (slightly extended and 35 degrees (moderately extended wrist extension positions (maintained by wrist splints on both involved and uninvolved sides of athletes and non-athletes with unilateral lateral epicondylitis of atleast 3 months duration. Their pain was to be elicited with local tenderness and two of three tests being positive- Cozen's, Mill's manoeuvre, resisted middle finger extension tests. For comparisons of grip strength, Wilcoxon signed rank test was used for within-group comparison (between 15 and 35 degrees wrist extension positions and Mann-Whitney U test was used for between-group (athletes vs. non-athletes comparisons at 95% confidence interval and were done using SPSS 11.5 for Windows. Results Statistically significant greater grip strength was found in 15 degrees (27.75 ± 4.2 kgms in athletes; 16.45 ± 4.2 kgms in non-athletes wrist extension than at 35 degrees (25.25 ± 3.53 kgm in athletes and 14.18 ± 3.53 kgm in non-athletes. The athletes had greater grip strength than non-athletes in each of test positions (11.3 kgm at 15 degrees and 11.07 kgm at 35 degrees measured. There was also a significant difference between involved and uninvolved sides' grip strength at both wrist

  13. COMPARISON OF ACTIVE RELEASE TECHNIQUE AND MYOFASCIAL RELEASE TECHNIQUE ON PAIN, GRIP STRENGTH & FUNCTIONAL PERFORMANCE IN PATIENTS WITH CHRONIC LATERAL EPICONDYLITIS

    Directory of Open Access Journals (Sweden)

    Parth Trivedi

    2014-06-01

    Full Text Available Background & Purpose: Lateral epicondylitis is the most common lesion of the elbow. Tennis elbow or lateral epicondylitis is defined as a syndrome of pain in the wrist extensor muscles at or near their lateral epicondyle origin or pain directly over the lateral epicondyle. So, the aim of this study was to compare the effectiveness of Active Release Technique (ART and Myofascial Release Technique (MFR in the treatment of Chronic Lateral Epicondylitis (CLE. Methodology: The study included thirty-six patients with Chronic Lateral Epicondylitis of age group range between 30 to 45 years. Patients were randomly divided into three groups: Control Group (A, Active Release Technique Group (B and Myofascial Release Technique Group (C. The patients were treated for 4 weeks and three outcome measures: 0-10 NPRS, Hand Dynamometer and PRTEE were taken for assessment and analysis at baseline and after 4th weeks was done. Result: In this study the result showed that Active Release Technique and Myofascial Release Technique were effective in all three outcome measures when compared to Control Group. Myofascial Release Technique was more effective in improving grip strength & reducing pain & disability when compared to Active Release Technique.(p<0.05 Conclusion: Active Release Technique and Myofascial Release Technique are effective in patients with Chronic Lateral Epicondylitis. Myofascial Release Technique demonstrated better outcomes than Active Release Technique in the management of Chronic Lateral Epicondylitis.

  14. Foreign Researches of the Relationship Among Grip Strength, Health and Fitness for Older Adults%老年人握力与健康及体适能关系的国外研究现状

    Institute of Scientific and Technical Information of China (English)

    张春华; 叶长林

    2013-01-01

    The measurement of hand grip strength has gained attention as a simple, non-invasive marker of muscle strength of upper extremities, and more and more researches show that it well suitable for clinical use. This review outlines the prognostic relevance of grip strength in various clinical and epidemiologic settings and describes the relationship between grip strength and fitness for older adults.%握力作为一项简单、无创的上肢肌肉力量测试指标而为人们所关注,越来越多的研究显示握力测试应用于临床也是适合的。这篇文献综述概述了在临床医学和流行病学领域里老年人握力的关联与预测,同时也描述了握力与体适能之间的关系。

  15. Effect of elbow flexion, forearm rotation and upper arm abduction on MVC grip and grip endurance time.

    Science.gov (United States)

    Farooq, Mohd; Khan, Abid Ali

    2012-01-01

    This experiment was designed to know the effect of upper limb postural deviations on grip strength and grip endurance time. A full factorial design of experiment, i.e., 3 (0°, 45°, 90° abduction angles of upper arm) × 3 (45°, 90°, 135° angles of elbow flexion) × 3 (0°, -60° prone, +60° supine angles of forearm rotation) was used to find the effect of 27 combinations of postures on maximum voluntary contraction (MVC) grip strength and grip endurance time. The results showed that none of the main factors were significant on MVC grip, although there was a change in MVC grip. Grip endurance time significantly decreased with an increase in upper arm abduction. Also, grip endurance significantly increased with the elbow flexion angle and decreased with forearm rotation from neutral. These data will help designers and engineers to improve the workplace and tools to reduce the risk of injuries.

  16. ANALYSIS OF POWER GRIP AND PINCH GRIP AMONG HEALTH CARE PROFESSIONALS

    Directory of Open Access Journals (Sweden)

    Zakariya M P

    2016-02-01

    Full Text Available Background: Grip and pinch strength are commonly employed indices of strength used in hand evaluations. Pinch grip and power grip strengths are used as indices of strength in hand therapy assessments. For all professions grip strength is an important criterion to be successful in their profession. Such phenomena may be explained by differences in nature of work, working environment, and objects workers handle. Method: 200 healthy subjects, satisfying the selection criteria were included and assessed with standardized procedure for power grip and pinch grip (lateral pinch, pad-pad, and tip-tip strength. They were divided in four groups, 50 group each according to profession i.e. medical surgeons, dentist, physiotherapists and nurses. Results: The mean power grip strength shows highly significant difference between medical vs. dental (p>0.01 and medical vs. physiotherapy group (p> 0.05 .The mean lateral pinch strength shows there is highly significant difference (p< 0.001 between dental vs. nursing profession and dental vs. physiotherapy group. No significant difference among other groups. The mean pad-pad pinch strength shows there is significant difference between dental vs. nursing (p< 0.05 and dental vs physiotherapy group (p< 0.05. The mean Tip-Tip pinch strength shows there is significant difference between dental vs nursing profession(p< 0.05 and dental vs. physiotherapy(p< 0.05. No significant different among other groups. Conclusion: Surgeons have highest power grip strength followed by Nursing, Physiotherapy and Dental professionals. Dentists have the maximum pinch strength in all three positions, followed by Surgeons, Nurses and Physiotherapists. Surgeons have maximum pinch strength next to Dentists.

  17. Relation of grip strength, bone mineral density and body mass index in postmenopausal women%绝经后女性握力和体重指数与骨密度的相关研究

    Institute of Scientific and Technical Information of China (English)

    吕波

    2014-01-01

    Objective To study the positive association between hand grip strength and bone mineral density in postmenopausal women.We conducted a screening program for osteoporosis in a large cohort of postmenopausal women to investigate the relation among hand grip strength,other nutritional parameters and bone density.Methods This investigation involved 973 volunteers from March 2012 to March 2013 at Tianjin Hongqiao Hospital.Bone mineral density,hand grip strength measurement,body mass index and T score were analyzed.Results Univariate analysis showed that hand grip strength measurement,body mass index and T score were correlated (Pearson correlation coefficient were 0.201,0.115,P =0.001,0.009) ; age and T score were negatively correlated(Pearson correlation coefficient were-0.358,P =0.001).Incidence of osteoporosis was 19.7% (192/973).Conclusion Both body mass index and handgrip strength are strongly correlated to bone mineral density.%目的 探讨绝经后女性握力和体重指数与骨密度之间的相关性.方法 收集2012年3月至2013年3月在天津市红桥医院检查治疗973名女性志愿者,所有志愿者均接受足跟部骨密度测量(T指数)、握力测试和体重指数测量并进行相关性分析.结果 在单变量分析中,握力和体重指数与T指数相关(Pearson相关系数分别为0.201、0.115,P=0.001、0.009),年龄与T指数呈负相关(Pearson相关系数为-0.358,P=0.001).骨质疏松发病率18.7%(182/973).有骨质疏松和无骨质疏松绝经年龄、握力比较[绝经年龄(48±6)岁比(49±5)岁,P=0.020;握力(23±6)kg比(24±6) kg,P=0.001].结论 体重指数和握力二者均与骨密度密切相关,二者可作为预示骨疾病的关键因子.

  18. Domo-Grip: functional evaluation and rehabilitation using grip force.

    Science.gov (United States)

    Hewson, David J; Li, Ke; Frerejean, Alexis; Hogrel, Jean-Yves; Duchene, Jacques

    2010-01-01

    Grip force measurement is routinely used to identify pathologies, evaluate muscular function, and as part of rehabilitation. Grip force has also been shown to be a good indicator of the capacity of elderly to live independently owing to its strong relationship with clinical tests such as the Index of Activities of Daily Living. An autonomous, communicant grip-force measurement device is presented in this paper in order to perform grip-force evaluation at home. The Domo-Grip system consists of the Grip-Ball, the Grip-Box, and Grip-Soft. The Grip-Ball measures the pressure resulting from grip force, the Grip-Box serves as the communication hub, while Grip-Soft is an interactive software suite. The Domo-Grip system can be used as part of a home-based rehabilitation, and also for functional evaluation as part of an assessment of the capacity of elderly to live autonomously.

  19. Construction of bent functions from near-bent functions

    DEFF Research Database (Denmark)

    Leander, Gregor; McGuire, G.

    2009-01-01

    We give a construction of bent functions in dimension 2m from near-bent functions in dimension 2m - 1. in particular, we give the first ever examples of non-weakly-normal bent functions in dimensions 10 and 12, which demonstrates the significance of our construction.......We give a construction of bent functions in dimension 2m from near-bent functions in dimension 2m - 1. in particular, we give the first ever examples of non-weakly-normal bent functions in dimensions 10 and 12, which demonstrates the significance of our construction....

  20. The effectiveness of low-level laser therapy on pain, self-reported hand function, and grip strength compared to placebo or "sham" treatment for adults with carpal tunnel syndrome: A systematic review.

    Science.gov (United States)

    Burger, Marlette; Kriel, Réna; Damon, Andrea; Abel, Amy; Bansda, Anisha; Wakens, Marinique; Ernstzen, Dawn

    2017-03-01

    Carpal tunnel syndrome (CTS) is one of the most common peripheral neuropathies in the upper extremity. The aim of this review was to systematically and critically appraise the available literature for the effectiveness of Low-Level Laser Therapy (LLLT) on pain, self-reported hand function, and grip strength compared to placebo treatment in adults with CTS. Seven databases were searched from 2000 to March 2015 namely: Cinahl, Cochrane Library, EBSCOhost, PEDro, PubMed, Science Direct, and Scopus. Key search terms were: CTS, LLLT, and physiotherapy. Specific inclusion and exclusion criteria were applied. The methodological quality was appraised with the PEDro scale. Data were extracted and captured on an Excel spreadsheet. The nine included randomized control trials (RCTs) had an average score of 8.2/11 according to the PEDro scale. The heterogeneity of the LLLT regimes used made statistical pooling inappropriate for this review and results were described narratively. No strong evidence exists concerning the effects of LLLT on CTS in adults. Studies that used 780-860 nm Lasers and energy dosages of 9-11 J/cm(2) or 10.8 J reported a more favorable outcome for pain, symptom severity, and functional ability as well as grip strength at the end of treatment and short-term follow up.

  1. Productivity and ergonomic investigation of bent-handle pliers.

    Science.gov (United States)

    Duke, Kelly; Mirka, Gary A; Sommerich, Carolyn M

    2004-01-01

    Awkward wrist posture is generally considered an occupational risk factor for hand/wrist disorders, leading to the ergonomic design principle of "bend the tool, not the wrist." Sixteen participants performed a computer jumper installation task and a simple assembly task while productivity, wrist posture, and shoulder posture were measured. The work surface orientation (vertical and 45 degrees) and the level of constraint placed on the user (constrained grip and unconstrained grip) were also varied. The results indicate that the beneficial effects of the bent-handle pliers are task dependent. In the computer jumper task the bent-handle pliers resulted in 5.3% faster task performance, whereas in the assembly task performance was 4.9% faster with the straight-handle pliers. The bent-handle pliers reduced shoulder deviations by 50% in the jumper installation task, and ulnar deviation was reduced by 12% and 22% for the jumper installation task and the assembly task, respectively (all significant at p ergonomic utility of bent-handle pliers can be considerable but that the 3-D kinematics characteristics of the task must be considered.

  2. Some Properties of Bent Functions

    Institute of Scientific and Technical Information of China (English)

    Ying Zhao

    2007-01-01

    First, this paper discusses and sums up some properties of a pair of functions p(x), q(x) that makes (y + 1)p(x) + yq(x) into a bent function. Then it discusses the properties of bent functions. Also, the upper and lower bounds of the number of bent functions on GF(2)2k are discussed.

  3. Comparative analysis of strength and crack resistance of normal sections of bent elements of T-sections, made of rubber concrete, kauton reinforcement and concrete

    Directory of Open Access Journals (Sweden)

    Potapov Yuriy

    2016-01-01

    Full Text Available One of the urgent tasks of development of the construction associated with the development of new building designs, the use of which provides increased strength, crack resistance, reducing the flow of construction materials, reducing the labor intensity, energy consumption and cost. Ensuring effective functioning of structures during their operation in the harsh environments associated not only with the task of developing materials of higher strength and corrosion resistance, but also composites of increased strength and crack resistance, as structural materials crack resistance is largely determined by the ability of the structure to prevent the formation and growth of cracks. For structures operating in conditions of chemical action, the question of crack resistance is paramount, as the disclosure of cracks in aggressive environment, penetrating deep into the section and causing corrosion of the reinforcement will significantly impair the ability of the load bearing capacity of the element as a whole. The results of experiments of polymer concrete beams of the cross T-profile and comparison of the results with those obtained in an experiment similar to concrete and kauton reinforced elements are given. The observations of the stress-strain state of polymer concrete of flexural members, strength and crack resistance of these elements are presented.

  4. The Reliability and Validity of Toe Grip Strength as an Index of Physical Development in 4- to 5-Year-Old Children

    Institute of Scientific and Technical Information of China (English)

    Takahiro Ikeda[1; Osamu Aoyagi[2

    2015-01-01

    Studies on TGS (toe-grip strength) are currently proliferating as a result of the development of the dynamometer. The purpose of the present study was to investigate the reliability and validity of TGS as a physical function in preschool aged children. The participants were 153 preschoolers. Each participant was measured in terms of his or her TGS and completed a MAT (motor ability test). The reliability of the measurements was investigated via Pearson's r and Cronbach's a through a test-retest method, as well as a Bland-Altman plot. The validity of the TGS value was investigated by measuring the correlation between TGS and each component of the MAT, the principal component analysis, and a two-way layout ANOVA with general linear model (gender and age). All reliability coefficients were more than 0.70. Though all components of the MAT relating to TGS were found to be significant (P 〈 0.05), these correlations were weak. However, TGS was found to be a physical function that relating to the lower limbs and develops with aging. Therefore, TGS was found to be a highly reliable measure of physical function performance in preschoolers.

  5. Gripping tool for the ITER upper port plug RH extraction/insertion

    Energy Technology Data Exchange (ETDEWEB)

    Rosa, Elena V., E-mail: elena.rosa@ciemat.es; Ríos, Luis, E-mail: luis.rios@ciemat.es

    2014-10-15

    Highlights: •The gripping tool is based on only one gripping point centred at the plug bottom. •The gripping tool should allow the relative displacement in the gripping point to absorb the misalignment between plug and tractor. •The gripping tool needs to withstand around 100/30 kN during the plug extraction/insertion. •The gripping tool should rely on visual control and it has to avoid force feed-back. •The comparison between the features of several gripping tool concepts is assessed. -- Abstract: The conceptual design of several gripping tools and their mechanical interfaces is being carried out for the ITER ECH UPP within the WP10-GOTRH programme. EFDA finances the GOT RH (Goal Oriented Training Programme for Remote Handling). The purpose of this paper is to introduce new concepts of gripping tools for the plug extraction/insertion in the upper port of ITER. All these gripping tools are designed according to IO input data and geometrical constraints. The gripping tools have to be able to extract/insert the plug in the scenario of maximum misalignment between the plug and the tractor. The paper also defines the functional requirements the gripping tools need to comply with. The requirements and input data are verified and validated through 3D simulation with Catia mock-ups of the gripping tools. The strengths and weaknesses of each gripping tool model are compared.

  6. A cross-sectional analysis of age and sex patterns in grip strength, tooth loss, near vision and hearing levels in Chinese aged 50-74 years

    DEFF Research Database (Denmark)

    Wu, Yili; Pang, Zengchang; Zhang, Dongfeng

    2012-01-01

    By focusing on four health variables, handgrip strength, near visual acuity, tooth loss and hearing level, this study examined the different patterns of age-related changes in these variables in Chinese aged from 50 to 74 years, as well as explored the relationship among the variables in a cross-...

  7. The composition of a graph on the decline of total body strength with age based on pushing, pulling, twisting and gripping force

    NARCIS (Netherlands)

    Voorbij, A.I.M.; Steenbekkers, L.P.A.

    2001-01-01

    This study, part of a large project on design-relevant characteristics of ageing users, aims to provide more insight in the possibilities and limitations of the procedure of extrapolation and calculation of human strength for transgenerational designThis study is part of a large project on design-re

  8. Effect of Sevoflurane on the Grip Strength of Mice by Intrathecal and Intracerebroventricular Injection%鞘内注射和侧脑室注射七氟烷对小鼠抓力的影响研究

    Institute of Scientific and Technical Information of China (English)

    周美艳; 张明阳; 刘亚君; 戴体俊

    2011-01-01

    OBJECTIVE: To study the main site of muscle-relaxation induced by sevoflurane (Sev). METHODS: 64 mice were randomly divided into intrathecal injection (it) group and intracerebroventricular injection (icv) group. Then it group and icv group were redivided into aCSF group (0.25 μL·g-1), Sev1 group (0.25 mg·g-1), Sev2 group (0.31 mg·g-1), Sev3 group (0.39 mg·g-1) with each group of 8 mice. The duration of injection was 10 s and acupuncture manipulation time lasted for 15 s. The grip strength of mice were recorded before administration and 5, 10, 15, 20, 25, 30 min after administration. RESULTS: Compared with aCSF group, the grip strength of mice in each group had reduced as the concentration of Sev increased, there was significant difference between Sev2 group and Sev3 group (P<0.05 or P<0.01 ). Compared with icv groups, the grip strength of mice in Sev2 group and Sev3 group of it group had reduced (P<0.01). CONCLUSION: Intratheeal and intracerebroventricular injection of sevoflurane produce muscle relaxation effect in dose-dependent manner, especially in it group. It can be concluded that spinal cord is the main site of muscle-relaxation induced by sevoflurane.%目的:研究七氟烷(Sev)产生肌松作用的主要部位.方法:将64只小鼠按基础抓力、体重,用分层随机区组设计均分为鞘内(it)注射组和侧脑室(icv)注射组,每组再各分为人工脑脊液(aCSF)组(0.25 uJL·g)、Sev1组(0.25 mg·g)、Sev2组(0.31 mg·g)、Scv3组(0.39mg·g),每小组8只,给予相应药物,注射时间为10 S,留针时间为15 S,考察各组小鼠给药前和给药后5、10、15、20、25、30min的抓力变化.结果:与aCSF组比较,it和icy注射Sev各组小鼠抓力均减小,且注射Sev浓度越高小鼠抓力越小,其中Sev2组和Sev3具有显著性差异(JD<0.05或P<0.01);与icv组比较,it组中的Sev2组、Sev3组小鼠抓力均显著减小(P<0.01).结论:it和icv注射Sev后均可产生剂量依赖性的肌松作用,但相同剂量

  9.   Bente Boa, Torm, Denmark

    DEFF Research Database (Denmark)

    Wagtmann, Maria Anne

    2009-01-01

    At the beginning of July 2009, Maria Anne Wagtmann (Associate Professor, PhD, University of Southern Denmark) had the opportunity to interview Ms Bente Boa, a senior marine HR manager in the Danish ship owning firm TORM A/S' ( http://www.torm.com/ ). Bente Boa is also chairwoman of the "The Sea...

  10. Daily multi-micronutrient supplementation during tuberculosis treatment increases weight and grip strength among HIV-uninfected but not HIV-infected patients in Mwanza, Tanzania

    DEFF Research Database (Denmark)

    PrayGod, George; Range, Nyagosya; Faurholt-Jepsen, Daniel

    2011-01-01

    Undernutrition is common among tuberculosis (TB) patients. The objective of this study was to assess the effect of multi-micronutrient supplementation during TB treatment on weight, body composition, and handgrip strength. A total of 865 patients with smear-positive (PTB+) or -negative (PTB......-) pulmonary TB were randomly allocated to receive a daily biscuit with or without multi-micronutrients for 60 d during the intensive phase of TB treatment. Weight, arm fat area, arm muscle area, and handgrip strength were assessed at baseline and after 2 and 5 mo. At 2 mo, the multi-micronutrient...... supplementation led to a higher handgrip gain (1.22 kg; 95% CI = 0.50, 1.94; P = 0.001) but had no effects on other outcomes. The effects of multi-micronutrient supplementation were modified by HIV infection (P-interaction = 0.002). Among HIV- patients, multi-micronutrient supplementation increased weight gain...

  11. Bent Marshak Waves

    Energy Technology Data Exchange (ETDEWEB)

    Hurricane, O A; Hammer, J H

    2005-10-11

    Radiation driven heat waves (Marshak Waves) are ubiquitous in astrophysics and terrestrial laser driven high energy density plasma physics (HEDP) experiments. Generally, the equations describing Marshak waves are so nonlinear, that solutions involving more than one spatial dimension require simulation. However, in this paper we show how one may analytically solve the problem of the two-dimensional nonlinear evolution of a Marshak wave, bounded by lossy walls, using an asymptotic expansion in a parameter related to the wall albedo and a simplification of the heat front equation of motion. Three parameters determine the nonlinear evolution, a modified Markshak diffusion constant, a smallness parameter related to the wall albedo, and the spacing of the walls. The final nonlinear solution shows that the Marshak wave will be both slowed and bent by the non-ideal boundary. In the limit of a perfect boundary, the solution recovers the original diffusion-like solution of Marshak. The analytic solution will be compared to a limited set of simulation results and experimental data.

  12. Comparison of Infant Car Seat grip orientations and lift strategies.

    Science.gov (United States)

    Clamann, Michael; Zhu, Biwen; Beaver, Leah; Taylor, Kinley; Kaber, David

    2012-07-01

    The rear-facing Infant Car Seat (ICS) is designed to meet federal requirements for transporting children less than 1 year old. Typical use includes transfer in and out of a vehicle, which is shown to be a difficult lift. Despite the frequency of this lift, manufacturers provide little guidance for users. Review of relevant literature suggested an ICS featuring an angled handle, promoting a neutral wrist posture, would increase grip stability and decrease lifting effort. Popular press suggested a foot-in-car stance for the ICS lift would do the same. An experiment was conducted in which wrist deviations from neutral posture were recorded along with lifting muscle activation levels (multiple flexor muscles and biceps brachii) and overall perceived exertion for straight versus a new bent handle design and conventional stance versus foot-in-car. Foot position was examined to test the recommendations in the popular press. Surprisingly, wrist deviation was not significantly affected by the new bent handle design (due to compensatory behavior with the straight handle) but was related to foot placement (p=0.04). Results revealed the bent handle to significantly reduce flexor activation compared with the straight handle (p=0.0003); however, the level of biceps activation increased. Biceps activation also significantly increased for foot-in-car stance (p=0.035) but not flexor activation. In general, the bent handle enabled the user to lift the ICS with a steadier grip and less effort. Copyright © 2011 Elsevier Ltd and The Ergonomics Society. All rights reserved.

  13. A new construction of bent functions based on Z-bent functions

    DEFF Research Database (Denmark)

    Gangopadhyay, Sugata; Joshi, Anand; Leander, Gregor

    2013-01-01

    Dobbertin has embedded the problem of construction of bent functions in a recursive framework by using a generalization of bent functions called -bent functions. Following his ideas, we generalize the construction of partial spreads bent functions to partial spreads -bent functions of arbitrary...

  14. Enter the Gripping Beast

    DEFF Research Database (Denmark)

    Sindbæk, Søren Michael

    2012-01-01

    of communities and their life world. Transcending technology, cultural dispositions and social relations, the study of innovations invites an actor-networks approach, which considers the heterogeneous nature of human-material relations. The archaeological record is potentially a rich source of evidence...... on innovations. Mostly, however, the time-resolution of archaeological data is too coarse-grained to allow us to grasp this potential to the full. In the period c. AD 790-850 a distinctly new artistic motif, the Gripping Beast, emerged in Scandinavia. A series of narrowly dated contexts provide anchor points...

  15. Effect of wrist position on young adults pinch grip control

    Directory of Open Access Journals (Sweden)

    Vanessa Luzia Barros de Andrade

    2015-12-01

    Full Text Available Pinch grip is used in a large number of handling activities that require precision and control of an object. The position of the upper arm joints affects the fingers force production in order to handle the object. This study aimed to verify the influence of the wrist position in the production of maximum strength and in the control fingers grip pinch submaximum strength control. Participants were 21 right handed adults (10 male, 18-26 years old. They made two attempts of maximum force production and eight attempts of submaximal force production (four at 20% and four at 40% of maximum strength for pinch grip in three wrist positions: neutral, flexion and extension. The results showed that the production of maximum strength is higher in neutral position compared to wrist flexion and extension and higher for men compared to women. In addition, there was a positive correlation between the length of the hand and the production of maximum strength. The results also indicated that the wrist position did not interfere in the submaximum force control during this task. However, participants showed more difficulty controlling 20% than 40% of maximum strength. The present study showed evidence that the motor units used to produce grip pinch maximum strength cross the wrist joint but those used for the 20% and 40% of maximum strength are present only in the fingers and hand.

  16. Medida da força de preensão manual- validade e confiabilidade do dinamômetro saehan Assessment of hand grip strength- validity and reliability of the saehan dynamometer

    Directory of Open Access Journals (Sweden)

    Maurício Moreira Reis

    2011-06-01

    Full Text Available Existe uma grande variedade de instrumentos utilizados para a avaliação da força de preensão manual. Porém, não existem estudos demonstrando a validade e a confiabilidade da maioria destes instrumentos. O objetivo deste estudo foi avaliar a validade concorrente e a confiabilidade intraexaminador do dinamômetro Saehan hidráulico comparado-o com o dinamômetro Jamar hidráulico. Cem indivíduos sadios (50 homens e 50 mulheres, entre 20 e 50 anos de idade, sem alterações cognitivas, deficiências físicas, disfunções neuromusculares e ortopédicas e história de lesões nos membros superiores, foram testados com os dinamômetros Jamar e Saehan. A validade concorrente entre o dinamômetro Jamar e o dinamômetro Saehan foi excelente para os testes de força de preensão realizados com as mãos direita (r=0,976 e esquerda (r=0,986. A confiabilidade intra-examinador foi excelente tanto para o dinamômetro Jamar (r=0,985 mãos direita e esquerda quanto para o dinamômetro Saehan (r=0,981 mão direita e r=0,985 mão esquerda. O dinamômetro Saehan é válido, confiável e comparável com o dinamômetro Jamar. Portanto, dados coletados com o dinamômetro Jamar são equivalentes aos dados coletados com o dinamômetro Saehan. Consequentemente, valores de força obtidos por testes com dinamômetro Saehan podem ser comparados com valores de referência de força de preensão que foram obtidos com o dinamômetro Jamar.There is a great variety of instruments available for evaluating hand grip strength. There is, however, a lack of studies showing the validity and reliability of most of these instruments. The purpose of this study was to examine the concurrent validity and test-retest reliability of the hydraulic Saehan dynamometer using the hydraulic Jamar dynamometer. One hundred healthy subjects (50 men and 50 women, between the ages of 20 and 50 years old, without cognitive impairment, physical disability, neuromuscular or orthopedic dysfunction

  17. Gait Speed and Grip Strength Reflect Cognitive Impairment and Are Modestly Related to Incident Cognitive Decline in Memory Clinic Patients With Subjective Cognitive Decline and Mild Cognitive Impairment: Findings From the 4C Study

    NARCIS (Netherlands)

    Hooghiemstra, A.M.; Ramakers, I.; Sistermans, N.; Pijnenburg, Y.A.; Aalten, P.; Hamel, R.E.; Melis, R.J.F.; Verhey, F.R.J.; Olde Rikkert, M.G.M.; Scheltens, P.; Flier, W.M. van der

    2017-01-01

    Background: Prospective studies in the general population show that slow gait speed is associated with cognitive decline and clinical progression to dementia. However, longitudinal studies in memory clinic populations are mostly lacking. We aimed to study the association between gait speed and grip

  18. Relationship between Multi-Output Partially Bent Functions and Multi-Output Bent Functions

    Institute of Scientific and Technical Information of China (English)

    ZHAO Yaqun; JU Guizhi; WANG Jue

    2006-01-01

    In this paper, the definition of multi-output partially Bent functions is presented and some properties are discussed. Then the relationship between multi-output partially Bent functions and multi-output Bent functions is given in Theorem 4, which includes Walsh spectrum expression and function expression. This shows that multi-output partially Bent functions and multi-output Bent functions can define each other in principle. So we obtain the general method to construct multi-output partially Bent functions from multi-output Bent functions.

  19. Comparative study of millennials' (age 20-34 years) grip and lateral pinch with the norms.

    Science.gov (United States)

    Fain, Elizabeth; Weatherford, Cara

    Cross-sectional research design. Clinical practice continues to use normative data for grip and pinch measurements that were established in 1985. There is no updated norms despite different hand usage patterns in today's society. Measuring and comparing grip and pinch strengths with normative data is a valid method to determine hand function. This research was implemented to compare the grip and pinch measurements obtained from healthy millennials to the established norms and to describe hand usage patterns for millennials. Grip and lateral pinch measurements were obtained from a sample of 237 healthy millennials (ages 20-34 years). Strength scores were statistically lower that older normative data in all millennial grip strengths, with the exception of the women in the age group of 30-34 years. Specifically, this statistically significant trend was observed in all male grip strengths, as well as in women in the age group of 20-24 years (bilateral grip) and 25-29 years (right grip). However, the lateral pinch data reflected was similar to the older norms with variances of 0.5-1 kg. Current data reflect statistically significant differences from the norms for all male grip measurements, as well as for women in the age group of 20-24 years (bilateral grip) and 25-29 years (right grip). No statistical significance was observed in the independent-sample t tests for the lateral pinch in men of all age groups. Statistical significance was noted for lateral pinch for female age groups for the left hand (20-24 years) and for bilateral lateral pinches (30-34 years). IV. Copyright © 2016 Hanley & Belfus. Published by Elsevier Inc. All rights reserved.

  20. Finding Relief from Allergy's Grip

    Science.gov (United States)

    ... Navigation Bar Home Current Issue Past Issues Finding Relief from Allergy's Grip Past Issues / Summer 2006 Table ... action for patients who have had inadequate symptom relief with antihistamines and topical nasal steroids. Through injection ...

  1. Ion implantation for manufacturing bent and periodically bent crystals

    Energy Technology Data Exchange (ETDEWEB)

    Bellucci, Valerio; Camattari, Riccardo; Guidi, Vincenzo, E-mail: guidi@fe.infn.it; Mazzolari, Andrea; Paternò, Gianfranco [Department of Physics and Earth Sciences, University of Ferrara, Via Saragat 1/c, 44122 Ferrara, Italy and INFN, Section of Ferrara (Italy); Mattei, Giovanni, E-mail: giovanni.mattei@unipd.it; Scian, Carlo [Department of Physics and Astronomy Galileo Galilei, University of Padova, Via Marzolo 8, 35131 Padova (Italy); Lanzoni, Luca [Dipertimento di Economia e Tecnologia, Università degli Studi della Repubblica di San Marino, Salita alla Rocca, 44, 47890 San Marino Città (San Marino)

    2015-08-10

    Ion implantation is proposed to produce self-standing bent monocrystals. A Si sample 0.2 mm thick was bent to a radius of curvature of 10.5 m. The sample curvature was characterized by interferometric measurements; the crystalline quality of the bulk was tested by X-ray diffraction in transmission geometry through synchrotron light at ESRF (Grenoble, France). Dislocations induced by ion implantation affect only a very superficial layer of the sample, namely, the damaged region is confined in a layer 1 μm thick. Finally, an elective application of a deformed crystal through ion implantation is here proposed, i.e., the realization of a crystalline undulator to produce X-ray beams.

  2. Proprioceptive neuromuscular facilitation and strength training to gain muscle strength in elderly women

    National Research Council Canada - National Science Library

    Cesário, Denise Ferreira; Mendes, Geovânia Barbosa da Silva; Uchôa, Érica Patrícia Borba Lira; Veiga, Paulo Henrique Altran

    2014-01-01

    ...: To perform comparative analyze of results of proprioceptive neuromuscular facilitation (PNF) techniques and strength training to gain muscle strength of biceps and quadriceps and grip in the elderly...

  3. Effects of Sensory Deficit on Phalanx Force Deviation During Power Grip Post Stroke.

    Science.gov (United States)

    Enders, Leah R; Seo, Na Jin

    2017-01-01

    The effect of sensory deficits on power grip force from individual phalanges was examined. The authors found that stroke survivors with sensory deficits (determined by the Semmes-Weinstein monofilament test) gripped with phalanx force directed more tangential to the object surface, than those without, although both groups had similar motor deficits (Chedoke-McMaster and Fugl-Meyer), grip strength, and skin friction. Altered grip force direction elevates risk of finger slippage against the object thus grip loss/object dropping, hindering activities of daily living. Altered grip force direction was associated with altered muscle activation patterns. In summary, the motor impairment level alone may not describe hand motor control in detail. Information about sensory deficits helps elucidate patients' hand motor control with functional relevance.

  4. Bent functions results and applications to cryptography

    CERN Document Server

    Tokareva, Natalia

    2015-01-01

    Bent Functions: Results and Applications to Cryptography offers a unique survey of the objects of discrete mathematics known as Boolean bent functions. As these maximal, nonlinear Boolean functions and their generalizations have many theoretical and practical applications in combinatorics, coding theory, and cryptography, the text provides a detailed survey of their main results, presenting a systematic overview of their generalizations and applications, and considering open problems in classification and systematization of bent functions. The text is appropriate for novices and advanced

  5. Gripping System For Mechanical Testing Of Composites

    Science.gov (United States)

    Mackay, Rebecca A.; Nathal, Michael V.

    1994-01-01

    Specimens held without slippage, even at high temperatures. Improved gripping system designed to securely hold ends of specimen of composite material during creep or tensile test. Each grip includes pair of wedges having sharply corrugated gripping surfaces. Wedges held between two plates containing cavities sloped to accommodate wedges. Two such grips (one for each end) holds specimen in furnace connected to tensile test machine for creep measurements.

  6. Hydraulically Driven Grips For Hot Tensile Specimens

    Science.gov (United States)

    Bird, R. Keith; Johnson, George W.

    1994-01-01

    Pair of grips for tensile and compressive test specimens operate at temperatures up to 1,500 degrees F. Grips include wedges holding specimen inside furnace, where heated to uniform temperature. Hydraulic pistons drive wedges, causing them to exert clamping force. Hydraulic pistons and hydraulic fluid remain outside furnace, at room temperature. Cooling water flows through parts of grips to reduce heat transferred to external components. Advantages over older devices for gripping specimens in high-temperature tests; no need to drill holes in specimens, maintains constant gripping force on specimens, and heated to same temperature as that of specimen without risk of heating hydraulic fluid and acuator components.

  7. Bent Electro-Absorption Modulator

    DEFF Research Database (Denmark)

    2002-01-01

    components and the applied electric field in relation to the frequency of the modulated radiation, the bending losses (and possibly coupling losses) will provide extinction of light guided by the bent waveguide section. The refractive index contract may be modulated while keeping the absorption coefficient...... substantially constant and small, whereby the guided light can be modulated only by bending losses. Alternatively, the invention may be applied to enhance the extinction ratio of existing absorption modulators such as Electro-Absorption Modulators (EAMs) in which case extinction by absorption and extinction......The present invention relates to a method and a device for modulating optical signals based on modulating bending losses in bend, quantum well semiconductor waveguide sections. The complex refractive index of the optical active semiconducting components of the waveguide section is modulated...

  8. Soft shape-adaptive gripping device made from artificial muscle

    Science.gov (United States)

    Hamburg, E.; Vunder, V.; Johanson, U.; Kaasik, F.; Aabloo, A.

    2016-04-01

    We report on a multifunctional four-finger gripper for soft robotics, suitable for performing delicate manipulation tasks. The gripping device is comprised of separately driven gripping and lifting mechanisms, both made from a separate single piece of smart material - ionic capacitive laminate (ICL) also known as artificial muscle. Compared to other similar devices the relatively high force output of the ICL material allows one to construct a device able to grab and lift objects exceeding multiple times its own weight. Due to flexible design of ICL grips, the device is able to adapt the complex shapes of different objects and allows grasping single or multiple objects simultaneously without damage. The performance of the gripper is evaluated in two different configurations: a) the ultimate grasping strength of the gripping hand; and b) the maximum lifting force of the lifting actuator. The ICL is composed of three main layers: a porous membrane consisting of non-ionic polymer poly(vinylidene fluoride-co-hexafluoropropene) (PVdF-HFP), ionic liquid 1-ethyl-3-methylimidazolium trifluoromethane-sulfonate (EMITFS), and a reinforcing layer of woven fiberglass cloth. Both sides of the membrane are coated with a carbonaceous electrode. The electrodes are additionally covered with thin gold layers, serving as current collectors. Device made of this material operates silently, requires low driving voltage (<3 V), and is suitable for performing tasks in open air environment.

  9. Motor cortical function and the precision grip.

    Science.gov (United States)

    Geevasinga, Nimeshan; Menon, Parvathi; Kiernan, Matthew C; Vucic, Steve

    2014-12-01

    While task-dependent changes in motor cortical outputs have been previously reported, the issue of whether such changes are specific for complex hand tasks remains unresolved. The aim of the present study was to determine whether cortical inhibitory tone and cortical output were greater during precision grip and power grip. Motor cortex excitability was undertaken by using the transcranial magnetic stimulation threshold tracking technique in 15 healthy subjects. The motor-evoked potential (MEP) responses were recorded over the abductor pollicis brevis (APB), with the hand in the following positions: (1) rest, (2) precision grip and (3) power grip. The MEP amplitude (MEP amplitude REST 23.6 ± 3.3%; MEP amplitude PRECISION GRIP 35.2 ± 5.6%; MEP amplitude POWER GRIP 19.6 ± 3.4%, F = 2.4, P < 0.001) and stimulus-response gradient (SLOPEREST 0.06 ± 0.01; SLOPEPRCISION GRIP 0.15 ± 0.04; SLOPE POWER GRIP 0.07 ± 0.01, P < 0.05) were significantly increased during precision grip. Short interval intracortical inhibition (SICI) was significantly reduced during the precision grip (SICI REST 15.0 ± 2.3%; SICI PRECISION GRIP 9.7 ± 1.5%, SICI POWER GRIP 15.9 ± 2.7%, F = 2.6, P < 0.05). The present study suggests that changes in motor cortex excitability are specific for precision grip, with functional coupling of descending corticospinal pathways controlling thumb and finger movements potentially forming the basis of these cortical changes.

  10. Bent and bent(4) spectra of Boolean functions over finite fields

    DEFF Research Database (Denmark)

    Anbar Meidl, Nurdagül; Meidl, Wilfried

    2017-01-01

    to the conventional Walsh transform, and hence a 0-bent4 function is bent. In this article we generalize the concept of partially bent functions to the transforms V-f(c). We show that every quadratic function is partially bent, and hence it is plateaued with respect to any of the transforms V-f(c). In detail we...... analyse two quadratic monomials. The first has values as small as possible in its spectra with respect to all transforms V-f(c), and the second has a flat spectrum for a large number of c. Moreover, we show that every quadratic function is c-bent4 for at least three distinct c. In the last part we analyse...... a cubic monomial. We show that it is c-bent(4) only for c = 1, the function is then called negabent, which shows that non-quadratic functions exhibit a different behaviour. (C) 2017 Elsevier Inc. All rights reserved....

  11. Correlações entre força de preensão manual e variáveis antropométricas da mão de jovens adultos Correlations between grip strength and anthropometric variables of young adults'hand

    Directory of Open Access Journals (Sweden)

    Luciane Fernanda Rodrigues Martinho Fernandes

    2011-06-01

    Full Text Available O objetivo do estudo foi correlacionar a força de preensão palmar em diferentes posições de abertura, com variáveis antropométricas da mão. Participaram 73 voluntários de ambos os sexos (40 homens e 33 mulheres, com idade média de 23±4,61 anos. As medidas antropométricas largura da palma, comprimento do dedo indicador, espessura da palma, largura da mão, circunferência da palma e da mão foram realizadas bilateralmente. Para as medidas lineares, utilizou-se um paquímetro digital e, para as medidas de circunferência, a fita métrica. As medidas de força de preensão foram realizadas por meio de um dinamômetro hidráulico (UFTM Jamar®. Os valores antropométricos foram correlacionados com as medidas de força nas cinco posições de abertura. Os homens e as mulheres tiveram maior força na mão direita e, entre as posições, a maior força dos homens foi na de número 3 (45,5±15,53 kgf e das mulheres, na de posição 2 (25,5±6,28 kgf. Verificaram-se correlações significativas entre a força e os valores antropométricos nas medidas da largura da mão e circunferência da palma - que representam a maior medida transversal e o maior trofismo da mão, respectivamente, no grupo dos homens e a medida de comprimento do dedo, que representa a maior medida longitudinal no grupo das mulheres. Com isso, pode-se concluir que, para os homens, a maior força está relacionada à maior medida transversal e ao maior trofismo da mão e, para as mulheres, ao maior comprimento longitudinal da mão.The aim of this study was to correlate the grip strength of hand, in different opening positions, with hand anthropometric measures. The study included 73 volunteers (40 male and 33 female with mean age of 23±4.61 years old. Anthropometric measures, such as palm width, forefinger length, palm thickness, hand width, palm and hand circumferences, were performed bilaterally. For linear measures, a digital caliper rule was used as well as a tape

  12. Força de preensão palmar e pinça digital em diferentes grupos de pilotos da Academia da Força Aérea brasileira Grip and pinch strength among different groups of Brazilian Air Force pilots

    Directory of Open Access Journals (Sweden)

    Gláucia Helena Gonçalves

    2010-06-01

    Full Text Available Pilotos da Academia de Força Aérea (AFA brasileira, durante vôos, realizam movimentos com grande solicitação da musculatura da mão que comanda o manche, o que pode modificar a força muscular. Este estudo teve por objetivo analisar as forças musculares isométricas de preensão palmar e pinças polpa-a-polpa, trípode e lateral de três grupos de pilotos da AFA. Foram avaliados 15 pilotos da Esquadrilha da Fumaça (EDA, 16 instrutores de vôo (PI e 6 pilotos em treinamento (PT, todos do sexo masculino. Para a avaliação, o posicionamento corporal dos pilotos seguiu a padronização da Sociedade Americana de Terapeutas da Mão e a ordem dos movimentos analisados foi predefinida, evitando fadiga muscular. A força muscular isométrica máxima foi coletada em uma contração sustentada por 6 segundos. Os resultados mostram diferenças significativas na preensão, com superioridade das mãos dominantes em relação às não-dominantes em todos os grupos, tendo ainda o grupo EDA obtido valores significativamente superiores em relação aos demais. Nas medidas da pinça trípode, o grupo EDA apresentou significativos valores superiores aos do grupo PT, sendo encontrados valores das mãos dominantes superiores aos das não-dominantes nos grupos EDA e PI. Conclui-se que o treino específico da musculatura da mão durante o vôo, a especificidade e o período de treinamento interferem na força muscular isométrica da mão.Pilots from Brazilian Air Force Academy (AFA perform strentgth- and accuracy-demanding hand movements, which may modify muscle strength. The aim of this study was to analyse hand isometric strength of grip and pulp-to-pulp, tripode and lateral pinch in three groups of male AFA pilots: ADS (Air Demonstration Squadron, n=15; IP (instructor pilots, n=16; and TP (training pilots, n=6. Pilots body positioning during tests followed the standards of the American Society of Hand Therapists; the sequence of assessed movements was

  13. Hold, grasp, clutch or grab: consumer grip choices during food container opening.

    Science.gov (United States)

    Rowson, J; Yoxall, A

    2011-07-01

    Society is ageing and sadly that ageing leads to a host of issues, not least a society in which the majority are likely to have some loss of strength and dexterity. This can lead to complications in undertaking everyday tasks such as using transport, bathing or even handling and opening food. Packaging has to provide a multitude of services; to protect and preserve the product, to provide information to the consumer and not least to allow access to the contents. This access to packaging--or 'openability'--has become a significant issue for designers and manufacturers with the change in demographics as described above. Understanding the choices consumers make in how they manipulate packaging can help designers produce packaging that is more able to meet the requirements of modern society. Studies previously undertaken by the authors showed that consumers did use different grips when opening packaging and that certain grips were theoretically more comfortable and stronger than others. This paper outlines a further study whereby consumers were asked to apply the most common grips to a specially designed torque measuring device. Details were taken about the consumers: age, gender, occupation, hand size, plus their preferred grip choice for packaging of this type. The study showed that typically women chose a grip that maximised their opportunity of opening the closure and that this grip choice was more limited than that available for men. This has implications for inclusive design of many everyday products.

  14. Univariate Niho Bent Functions from o-Polynomials

    OpenAIRE

    Budaghyan, Lilya; Kholosha, Alexander; Carlet, Claude; Helleseth, Tor

    2014-01-01

    In this paper, we discover that any univariate Niho bent function is a sum of functions having the form of Leander-Kholosha bent functions with extra coefficients of the power terms. This allows immediately, knowing the terms of an o-polynomial, to obtain the powers of the additive terms in the polynomial representing corresponding bent function. However, the coefficients are calculated ambiguously. The explicit form is given for the bent functions obtained from quadratic and cubic o-polynomi...

  15. The ranks of Maiorana-McFarland bent functions

    Institute of Scientific and Technical Information of China (English)

    2008-01-01

    In this paper, the ranks of a special family of Maiorana-McFarland bent functions are discussed. The upper and lower bounds of the ranks are given and those bent functions whose ranks achieve these bounds are determined. As a consequence, the inequivalence of some bent functions are derived. Furthermore, the ranks of the functions of this family are calculated when t 6.

  16. 司坦唑醇对高营养风险危重患者氮平衡、握力及临床预后影响的研究%Effect of stanozolol on the nitrogen balance,grip strength and clinical outcomes of critical patients with high nutrition risk

    Institute of Scientific and Technical Information of China (English)

    王宇辉; 龙大利; 叶八宁; 施贤清

    2015-01-01

    Objective To investigate the effect of stanozolol on nitrogen balance ,grip strength and clinical outcomes of criti‐cal patients with high nutrition risk .Methods We enrolled patients who were admitted to the ICU of Guizhou provincial Hospital during the time period from January 2014 to June 2014 and ,as patients with high nutrition risk .Patients ,who received same base nutritional support program ,were divided into two groups .Treatment group who were treated with stanozolol administrated with gastric or jejunal tube for 7 days by 4 mg Tid .The control group whose members underwent placebo simultaneously with the treat‐ment group .The nitrogen balance ,grip strength of both groups was measured when at admitted and 4th as well as 7th day .Prealbu‐min ,total bilirubin ,alanine aminotransferase ,and aspartate aminotransferase were measured when at the same time and before leave hospital .The duration of the mechanical ventilation ,ICU stays ,hospital stays and mortality within 28 days were recorded .Results There was no statistical significance in the differences between all the indicators of the two groups at admission(P>0 .05) .The du‐ration of mechanical ventilation ,ICU stays ,hospital stays were decreased significantly in the treatment group (P0 .05) .Nitrogen bal‐ance ,prealbumin ,grip strength and liver function parameters in the treatment group were significantly higher than they were been at admitted and control group at 4th and 7th day (all P<0 .05) .Liver function parameters of treatment group gradually decreased to the normal range before discharge .Conclusion In critically ill patients treated with anabolic steroid stanozolol ,can promote protein synthesis ,reduce muscle and other lean tissue decomposition ,improve clinical symptoms ,short the length of hospital stay and ICU stay .But we should pay more attention on liver function in critically ill patients who treated with stanozolol .%目的:探讨司坦唑醇对高营养风险危重患

  17. Avaliação da função manual e da força de preensão palmar máxima em indivíduos com diabetes mellitus Hand function and power grip strength assessment in individuals with diabetes mellitus

    Directory of Open Access Journals (Sweden)

    Kauê Carvalho de Almeida Lima

    2012-12-01

    involving object manipulation. The aim of the study was to compare the performance of diabetic individual without diagnosis of neuropathy with non-diabetic healthy individuals in manipulation task and their maximum power grip strength. Thirteen diabetic individuals without peripheral neuropathy diagnosis (48.6±11.51 years-old; 79.9±10.88 kg; 1.68±0.09 m and 13 healthy age- and gender-matched controls (48.5±10.09 years-old; 76.44±11.79 kg; 1.69±0.1 m participated in the study. Hand cutaneous sensitivity was assessed by the Semmes-Weinstein monofilaments examination (SWME followed by the application of three tests commonly used to assess hand function: Jebsen-Taylor hand function test (JTHFT, nine hole peg test (9HPT and maximum power grip strength test (GSmax. The results of SWME revealed that eight diabetic individuals presented normal cutaneous sensitivity and five showed mild sensory losses, but that was not enough to characterize them as neuropathic diabetics. Regarding the hand function tests, the results revealed no difference between diabetic individuals and healthy controls in any of the tests performed (diabetic individuals and controls - JHHFT: 26.15±3.06 and 25.78±1.29 s; 9HPT: 15.33±1.35 and 15.48±2.39 s; GSmax: 41.15±10.59 and 43.69±12.59 kgf. Therefore, we conclude that diabetic individuals without neuropathy show no hand function impairment, as well as no reduction in the maximum power grip strength.

  18. The ranks of Maiorana-McFarland bent functions

    Institute of Scientific and Technical Information of China (English)

    WENG GuoBiao; FENG RongQuan; QIU WeiSheng; ZHENG ZhiMing

    2008-01-01

    In this paper,the ranks of a special family of Maiorana-McFarland bent functions are discussed.The upper and lower bounds of the ranks are given and those bent functions whose ranks achieve these bounds are determined.As a consequence,the inequivalence of some bent functions are derived.Furthermore,the ranks of the functions of this family are calculated when t≤6.

  19. Temperature limit values for gripping cold surfaces

    NARCIS (Netherlands)

    Malchaire, J.; Geng, Q.; Den Hartog, E.; Havenith, G.; Holmer, I.; Piette, A.; Powell, S.L.; Rintamäki, H.; Rissanen, S.

    2002-01-01

    Objectives. At the request of the European Commission and in the framework of the European Machinery Directive, research was conducted jointly in five different laboratories to develop specifications for surface temperature limit values for the gripping and handling of cold items. Methods. Four

  20. Temperature limit values for gripping cold surfaces

    NARCIS (Netherlands)

    Malchaire, J.; Geng, Q.; Den Hartog, E.; Havenith, G.; Holmer, I.; Piette, A.; Powell, S.L.; Rintamäki, H.; Rissanen, S.

    2002-01-01

    Objectives. At the request of the European Commission and in the framework of the European Machinery Directive, research was conducted jointly in five different laboratories to develop specifications for surface temperature limit values for the gripping and handling of cold items. Methods. Four hund

  1. Grip-Pattern Recognition for Smart Guns

    NARCIS (Netherlands)

    Kauffman, J.A.; Bazen, A.M.; Gerez, S.H.; Veldhuis, R.N.J.

    2003-01-01

    This paper describes the design, implementation and evaluation of a user-verification system for a smart gun, which is based on grip-pattern recognition. An existing pressure sensor consisting of an array of 44 x 44 piezoresistive elements has been used. An interface has been developed to acquire pr

  2. The GRIP method for collaborative roadmapping workshops

    DEFF Research Database (Denmark)

    Piirainen, Kalle

    2015-01-01

    Technology roadmapping is a well-known tool for technology management, but practical advice for facilitating collaborative roadmapping workshops is relatively scarce. To cater for this need, we have designed a method for collaborative roadmapping, dubbed the GRIP method, for facilitating group work...

  3. Registration of hand-grip pattern in smart gun

    NARCIS (Netherlands)

    Shang, X.; Veldhuis, R.N.J.

    2006-01-01

    Secure Grip1 focuses on the development of a hand-grip pattern recognition system, as part of a smart gun. It is intended for use by the police. We collected the hand-grip data from police officers in three sessions in a row with time intervals in between. If data for training and testing come from

  4. [Reliability and validity of the analysis of hand grip and pinch force in isometric and isokinetic conditions].

    Science.gov (United States)

    Benaglia, P G; Franchignoni, F; Ferriero, G; Zebellin, G; Sartorio, F

    1999-01-01

    Strength measurement of the hand grip is at the core of most protocols of functional assessment of the upper limb and in rehabilitation plays a major role in the analysis of treatment efficacy and patients' occupational ability. The aims of this study were to: a) verify the repeatability of strength measurements made during performance of the hand grip and three types of pinch, carried out under isometric and isokinetic conditions; b) compare maximal isometric strength with the corresponding isokinetic value for each of the manoeuvres studied; c) investigate the correlations between the strength expressed in the different manoeuvres, under both isometric and isokinetic conditions. We studied 14 voluntary subjects over three sessions conducted at 48-hr intervals, employing a computerized isokinetic dynamometer Lido WorkSet equipped with device N(o) 21 for the study of pinch (lateral pinch, pulp pinch, chuck pinch) and device N(o) 52 for the grip study. Isometric contractions resulted stronger than isokinetic ones, and the hand grip was found to be the manoeuvre able to produce most strength. The repeatability of each strength measurement test over the three days was high (Intraclass Correlation Coefficients: 0.89-0.93). Correlations between the isometric and isokinetic performance for each of the manoeuvres examined were always high (Pearson's r coefficients: 0.89-0.95) as were those between the different manoeuvres, whether performed in isometric or isokinetic modality (r: 0.60-0.94).

  5. Bent Solenoids with Superimposed Dipole Fields

    Energy Technology Data Exchange (ETDEWEB)

    Meinke, Rainer, B.; Goodzeit, Carl, L.

    2000-03-21

    A conceptual design and manufacturing technique were developed for a superconducting bent solenoid magnet with a superimposed dipole field that would be used as a dispersion device in the cooling channel of a future Muon Collider. The considered bent solenoid is equivalent to a 180° section of a toroid with a major radius of ~610 mm and a coil aperture of ~416 mm. The required field components of this magnet are 4 tesla for the solenoid field and 1 tesla for the superimposed dipole field. A magnet of this size and shape, operating at these field levels, has to sustain large Lorentz forces resulting in a maximum magnetic pressure of about 2,000 psi. A flexible round mini-cable with 37 strands of Cu-NbTi was selected as the superconductor. Detailed magnetic analysis showed that it is possible to obtain the required superimposed dipole field by tilting the winding planes of the solenoid by ~25°. A complete structural analysis of the coil support system and the helium containment vessel under thermal, pressure, and Lorentz force loads was carried out using 3D finite element models of the structures. The main technical issues were studied and solutions were worked out so that a highly reliable magnet of this type can be produced at an affordable cost.

  6. Variability of grip kinetics during adult signature writing.

    Directory of Open Access Journals (Sweden)

    Bassma Ghali

    Full Text Available Grip kinetics and their variation are emerging as important considerations in the clinical assessment of handwriting pathologies, fine motor rehabilitation, biometrics, forensics and ergonomic pen design. This study evaluated the intra- and inter-participant variability of grip shape kinetics in adults during signature writing. Twenty (20 adult participants wrote on a digitizing tablet using an instrumented pen that measured the forces exerted on its barrel. Signature samples were collected over 10 days, 3 times a day, to capture temporal variations in grip shape kinetics. A kinetic topography (i.e., grip shape image was derived per signature by time-averaging the measured force at each of 32 locations around the pen barrel. The normalized cross correlations (NCC of grip shape images were calculated within- and between-participants. Several classification algorithms were implemented to gauge the error rate of participant discrimination based on grip shape kinetics. Four different grip shapes emerged and several participants made grip adjustments (change in grip shape or grip height or rotated the pen during writing. Nonetheless, intra-participant variation in grip kinetics was generally much smaller than inter-participant force variations. Using the entire grip shape images as a 32-dimensional input feature vector, a K-nearest neighbor classifier achieved an error rate of 1.2±0.4% in discriminating among participants. These results indicate that writers had unique grip shape kinetics that were repeatable over time but distinct from those of other participants. The topographic analysis of grip kinetics may inform the development of personalized interventions or customizable grips in clinical and industrial applications, respectively.

  7. Variability of grip kinetics during adult signature writing.

    Science.gov (United States)

    Ghali, Bassma; Thalanki Anantha, Nayanashri; Chan, Jennifer; Chau, Tom

    2013-01-01

    Grip kinetics and their variation are emerging as important considerations in the clinical assessment of handwriting pathologies, fine motor rehabilitation, biometrics, forensics and ergonomic pen design. This study evaluated the intra- and inter-participant variability of grip shape kinetics in adults during signature writing. Twenty (20) adult participants wrote on a digitizing tablet using an instrumented pen that measured the forces exerted on its barrel. Signature samples were collected over 10 days, 3 times a day, to capture temporal variations in grip shape kinetics. A kinetic topography (i.e., grip shape image) was derived per signature by time-averaging the measured force at each of 32 locations around the pen barrel. The normalized cross correlations (NCC) of grip shape images were calculated within- and between-participants. Several classification algorithms were implemented to gauge the error rate of participant discrimination based on grip shape kinetics. Four different grip shapes emerged and several participants made grip adjustments (change in grip shape or grip height) or rotated the pen during writing. Nonetheless, intra-participant variation in grip kinetics was generally much smaller than inter-participant force variations. Using the entire grip shape images as a 32-dimensional input feature vector, a K-nearest neighbor classifier achieved an error rate of 1.2±0.4% in discriminating among participants. These results indicate that writers had unique grip shape kinetics that were repeatable over time but distinct from those of other participants. The topographic analysis of grip kinetics may inform the development of personalized interventions or customizable grips in clinical and industrial applications, respectively.

  8. Systemic transthyretin amyloidosis in a patient with bent spine syndrome.

    Science.gov (United States)

    Rezania, Kourosh; Pytel, Peter; Smit, Laurel J; Mastrianni, James; Dina, Michelle A; Highsmith, W Edward; Dogan, Ahmet

    2013-06-01

    Wild-type and mutant transthyretin (TTR) are implicated in systemic amyloidosis (ATTR). Myopathy is a rare complication of ATTR amyloidosis, however no patient with bent spine syndrome secondary to ATTR amyloidosis has been reported so far. We present the first case of bent spine syndrome in a patient with wild-type ATTR amyloidosis who also had concomitant Alzheimer's disease.

  9. Niho Bent Functions and Subiaco/Adelaide Hyperovals

    OpenAIRE

    Helleseth, Tor; Kholosha, Alexander; Mesnager, Sihem

    2012-01-01

    In this paper, the relation between binomial Niho bent functions discovered by Dobbertin et al. and o-polynomials that give rise to the Subiaco and Adelaide classes of hyperovals is found. This allows to expand the class of bent functions that corresponds to Subiaco hyperovals, in the case when $m\\equiv 2 (\\bmod 4)$.

  10. Optimal work-rest cycles for an isometric intermittent gripping task as a function of force, posture and grip span.

    Science.gov (United States)

    Eksioglu, Mahmut

    2006-02-10

    The aim of this study was to investigate the maximum acceptable contraction frequencies (i.e. work-rest cycles) for an isometric-intermittent handgrip task as a function of grip span, applied force and shoulder posture using psychophysical and physiological approaches. Twelve healthy males served as subjects. The three grip spans investigated were the optimal, 2 cm narrower than the optimal, and 2 cm wider than the optimal. The grip force levels studied were 15% and 30% of maximum voluntary grip force and the two shoulder postures were 25 degrees flexion and 30 degrees abduction. The psychophysical results indicate that subjects work faster with the narrower grip span at 15% of maximum voluntary grip force level in comparison to working with the optimal and the wider spans. However, when the task required 30% of maximum grip force level, the subjects worked faster with the optimal grip span. These findings were supported by the results of electromyography, heart rate, blood pressure and perceived discomfort. The study suggests that grip span of a tool is an important factor to be considered in predicting optimal work-rest cycles for hand grip tasks, and the optimum setting of grip span of the hand-tool depends on the required task force level. That is, the optimality is relative rather than absolute. In addition, it appears that weaker subjects can work at a higher rate than stronger ones at the same relative force level.

  11. Differential roles for NSF and GRIP/ABP in AMPA receptor cycling.

    Science.gov (United States)

    Braithwaite, Steven P; Xia, Houhui; Malenka, Robert C

    2002-05-14

    alpha-Amino-3-hydroxy-5-methylisoxazole-4-propionic acid receptor (AMPAR) stability and movement at synapses are important factors controlling synaptic strength. Here, we study the roles of proteins [N-ethylmaleimide-sensitive fusion protein (NSF), glutamate receptor AMPAR binding protein (ABP)-interacting protein (GRIP)/(ABP), and protein interacting with C-kinase-1 (PICK1) that interact with the GluR2 subunit in the control of the surface expression and cycling of AMPARs. Epitope-tagged GluR2 formed functional receptors that exhibited targeting to synaptic sites. Constructs in which binding to NSF, PDZ proteins (GRIP/ABP and PICK1), or GRIP/ABP alone was eliminated each exhibited normal surface targeting and constitutive cycling. The lack of NSF binding, however, resulted in receptors that were endocytosed to a greater extent than wild-type receptors in response to application of AMPA or N-methyl-d-aspartate (NMDA). Conversely, the behavior of the GluR2 mutants incapable of binding to GRIP/ABP suggests that these PDZ proteins play a role in the stabilization of an intracellular pool of AMPARs that have been internalized on stimulation, thus inhibiting their recycling to the synaptic membrane. These results provide further evidence for distinct functional roles of GluR2-interacting proteins in AMPAR trafficking.

  12. ASSESSMENT OF GRIP FORCE CONTROL IN PATIENTS WITH MUSCULAR DYSTROPHY

    Directory of Open Access Journals (Sweden)

    Gregorij Kurillo

    2004-12-01

    Full Text Available Background. The majority of hand functionality tests are based on qualitative assessment which largely depends on the experience of the therapist. Computer-assisted methods can provide more objective and accurate measurements of the grip force and other parameters related to grasping.Methods. We analysed the grip force control in 12 patients with muscular dystrophy using the tracking system developed. The system consists of a grip-measuring device with endobjects assessing the force applied in different grips. The device was used as input to a tracking task where the patient applied the grip force according to the visual feedback from the computer screen. Each patient performed two tasks which consisted of tracking a ramp and sinus target.Results. We analysed the maximal grip force as assessed in the ramp task and the tracking accuracy of the sinus task. The results are compared among five different grips (cylindrical, lateral, palmar, pinch and spherical grip, applied with dominant and non-dominant hand. The results show no significant difference in tracking accuracy between the dominant and non-dominant hand.Conclusions. The results obtained in tracking the ramp target showed that the method could be used for the assessment of the muscle fatigue, providing quantitative information on muscle capacity. The results of the sinus-tracking task showed that the method can evaluate the grip force control in different types of grips, providing information on hand dexterity, muscle activation patterns or tremor.

  13. Validade preditiva de equações de referência para força de preensão manual em homens brasileiros de meia idade e idosos Predictive validity of reference equations to hand grip strength in Brazilian men of middle age and elderly

    Directory of Open Access Journals (Sweden)

    Alex de Andrade Fernandes

    2012-12-01

    Full Text Available O objetivo deste estudo foi verificar a validade preditiva das equações de referência para predição da força de preensão manual (FPM em homens brasileiros de meia idade e idosos. Foram avaliados 60 homens com idade de 58,7±8,6 anos (50-84 anos, estatura 168,7±8,0 cm, massa corporal 67,9±13,0 kg e índice de massa corporal 23,7±4,0 kg/m², utilizando equipamento 'padrão-ouro' na avaliação da FPM e seguindo todas as recomendações metodológicas preconizadas pela American Society of Hand Therapists (ASHT. Os resultados do diagrama de Bland-Altman para mão dominante (MD apresentam um erro médio (viés de -8,4% (IC95% -51,6-34,7. Já o diagrama de Bland-Altman para mão não dominante (MND apresenta um erro médio (viés de 1,4% (IC95% -47,1-49,8. O cálculo de Cronbach's alpha para a MD foi de 0,69 e 0,59 para MND. O coeficiente de correlação intraclasse para MD foi 0,52 (IC95% 31-68 e de 0,42 (IC95% 20-60 para a MND. Concluímos que as equações para predição analisadas neste estudo, para uma população de homens brasileiros de meia idade e idosos, apresentou baixa validade preditiva, o que pode gerar erros de interpretação dos resultados.The objective of this study was to verify the predictive validity of reference equations for hand grip strength (HGS in middle-aged and elderly Brazilian men. We evaluated 60 men with age of 58.7±8.6 years, height 168.7±8.0 cm, body mass 67.9±13.0 kg, and body mass index 23.7±4.0 kg/m², utilizing the gold standard equipment for evaluation of HGS and following all methodological recommendations of the American Society of Hand Therapists (ASTH. The results of the Bland-Altman diagram for the dominant hand (DH had a mean error (bias of -8.4% (95%CI -51.6-34.7. The Bland-Altman diagram for the non-dominant hand (NDH had a mean error (bias of 1.4% (95%CI -47.1-49.8. The calculation of Cronbach's alpha was 0.69 for the DH and 0.59 for the NDH. The intraclass correlation coefficient was 0

  14. Proximal arm kinematics affect grip force-load force coordination

    OpenAIRE

    Vermillion, Billy C.; Lum, Peter S; Lee, Sang Wook

    2015-01-01

    During object manipulation, grip force is coordinated with load force, which is primarily determined by object kinematics. Proximal arm kinematics may affect grip force control, as proximal segment motion could affect control of distal hand muscles via biomechanical and/or neural pathways. The aim of this study was to investigate the impact of proximal kinematics on grip force modulation during object manipulation. Fifteen subjects performed three vertical lifting tasks that involved distinct...

  15. Conditions for supersonic bent Marshak waves

    CERN Document Server

    Xu, Qiang; Li, Jing; Dan, Jia-kun; Wang, Kun-lun; Zhou, Shao-tong

    2014-01-01

    Supersonic radiation diffusion approximation is a useful way to study the radiation transportation. Considering the bent Marshak wave theory in 2-dimensions, and an invariable source temperature, we get the supersonic radiation diffusion conditions which are about the Mach number $M>8(1+\\sqrt{\\ep})/3$, and the optical depth $\\tau>1$. A large Mach number requires a high temperature, while a large optical depth requires a low temperature. Only when the source temperature is in a proper region these conditions can be satisfied. Assuming the material opacity and the specific internal energy depend on the temperature and the density as a form of power law, for a given density, these conditions correspond to a region about source temperature and the length of the sample. This supersonic diffusion region involves both lower and upper limit of source temperature, while that in 1-dimension only gives a lower limit. Taking $\\rm SiO_2$ and the Au for example, we show the supersonic region numerically.

  16. Channeling and radiation in periodically bent crystals

    CERN Document Server

    Korol, Andrey V; Greiner, Walter

    2014-01-01

    The development of coherent radiation sources for sub-angstrom wavelengths - i.e. in the hard X-ray and gamma-ray range -  is a challenging goal of modern physics. The availability of such sources will have many applications in basic science, technology and medicine, and, in particular, they may have a revolutionary impact on nuclear and solid state physics, as well as on the life sciences. The present state-of-the-art lasers are capable of emitting electromagnetic radiation from the infrared to the ultraviolet, while free electron lasers (X-FELs) are now entering the soft X-ray region. Moving further, i.e. into the hard X and/or gamma ray band, however, is not possible without new approaches and technologies.   In this book we introduce and discuss one such novel approach -the radiation formed in a Crystalline Undulator - whereby electromagnetic radiation is generated by a bunch of ultra-relativistic particles channeling through a periodically bent crystalline structure. Under certain conditions, such a d...

  17. Microspine Gripping Mechanism for Asteroid Capture

    Science.gov (United States)

    Merriam, Ezekiel G.; Berg, Andrew B.; Willig, Andrew; Parness, Aaron; Frey, Tim; Howell, Larry L.

    2016-01-01

    This paper details the development and early testing of a compliant suspension for a microspine gripper device for asteroid capture or micro-gravity percussive drilling. The microspine gripper architecture is reviewed, and a proposed microspine suspension design is presented and discussed. Prototyping methods are discussed, as well as testing methods and results. A path forward is identified from the results of the testing completed thus far. Key findings include: the microspine concept has been established as a valid architecture and the compliant suspension exhibits the desired stiffness characteristics for good gripping behavior. These developments will aid in developing the capability to grasp irregularly shaped boulders in micro-gravity.

  18. Study and Design of Spiral Bent Waveguide Configuration

    Institute of Scientific and Technical Information of China (English)

    ZENG Wen-hong; LIAO Yun; SHI Shuang-jin; QIU Qi; LI Wei

    2007-01-01

    A new version of the scalar transverse electric(TE) wave equation in the bent waveguide is introduced.Then,TE polarized field in curved single-mode waveguides is analyzed by using the finite-difference beam propagation method(FD-BPM).The bending loss in bent waveguides is gotten for the optical fields obtained from BPM and comparisons are made among losses of the waveguides with various curvature radiuses,refractive index differences and cross sections.Based on the results,the design of spiral bent waveguide configuration is proposed as follows:refractive index difference being of 0.007,both width and thickness of waveguides being of 6 μm,the curvature radius in the spiral centre being of 4 mm,and the bending loss coefficient of the designed spiral bent waveguide being of 0.302 3 dB/cm.

  19. Analysis list: Grip1 [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available Grip1 Blood + mm9 http://dbarchive.biosciencedbc.jp/kyushu-u/mm9/target/Grip1.1.tsv... http://dbarchive.biosciencedbc.jp/kyushu-u/mm9/target/Grip1.5.tsv http://dbarchive.biosciencedbc.jp/kyushu-u/mm9/target/Gri...p1.10.tsv http://dbarchive.biosciencedbc.jp/kyushu-u/mm9/colo/Grip1.Blood.tsv http://dbarchive.biosciencedbc.jp/kyushu-u/mm9/colo/Blood.gml ...

  20. Rotation Symmetric Bent Boolean Functions for n = 2p

    OpenAIRE

    Cusick, T. W.; Sanger, E. M.

    2017-01-01

    It has been conjectured that there are no homogeneous rotation symmetric bent Boolean functions of degree greater than two. In this paper we begin by proving that sums of short-cycle rotation symmetric bent Boolean functions must contain a specific degree two monomial rotation symmetric Boolean function. We then prove most cases of the conjecture in n=2p, p>2 prime, variables and extend this work to the nonhomogeneous case.

  1. Counting all bent functions in dimension eight 99270589265934370305785861242880

    DEFF Research Database (Denmark)

    Langevin, Philippe; Leander, Gregor

    2011-01-01

    Based on the classification of the homogeneous Boolean functions of degree 4 in 8 variables we present the strategy that we used to count the number of all bent functions in dimension 8. There are $$99270589265934370305785861242880 \\approx 2^{106}$$such functions in total. Furthermore, we show...... that most of the bent functions in dimension 8 are nonequivalent to Maiorana–McFarland and partial spread functions....

  2. Adaptive Human Control Gains During Precision Grip

    Directory of Open Access Journals (Sweden)

    Erik D. Engeberg

    2013-03-01

    Full Text Available Eight human test subjects attempted to track a desired position trajectory with an instrumented manipulandum (MN. The test subjects used the MN with three different levels of stiffness. A transfer function was developed to represent the human application of a precision grip from the data when the test subjects initially displaced the MN so as to learn the position mapping from the MN onto the display. Another transfer function was formed from the data of the remainder of the experiments, after significant displacement of the MN occurred. Both of these transfer functions accurately modelled the system dynamics for a portion of the experiments, but neither was accurate for the duration of the experiments because the human grip dynamics changed while learning the position mapping. Thus, an adaptive system model was developed to describe the learning process of the human test subjects as they displaced the MN in order to gain knowledge of the position mapping. The adaptive system model was subsequently validated following comparison with the human test subject data. An examination of the average absolute error between the position predicted by the adaptive model and the actual experimental data yielded an overall average error of 0.34mm for all three levels of stiffness.

  3. Forearm posture and grip effects during push and pull tasks.

    Science.gov (United States)

    Di Domizio, Jennifer; Keir, Peter J

    2010-03-01

    Direction of loading and performance of multiple tasks have been shown to elevate muscle activity in the upper extremity. The purpose of this study was to evaluate the effects of gripping on muscle activity and applied force during pushing and pulling tasks with three forearm postures. Twelve volunteers performed five hand-based tasks in supinated, neutral and pronated forearm postures with the elbow at 90 degrees and upper arm vertical. All tasks were performed with the right (dominant) hand and included hand grip alone, push and pull with and without hand grip. Surface EMG from eight upper extremity muscles, hand grip force, tri-axial push and pull forces and wrist angles were recorded during the 10 s trials. The addition of a pull force to hand grip elevated activity in all forearm muscles (all p push with grip tasks, forearm extensor muscle activity tended to increase when compared with grip only while flexor activity tended to decrease. Forearm extensor muscle activity was higher with the forearm pronated compared with neutral and supinated postures during most isolated grip tasks and push or pull with grip tasks (all p push and pull forces could act to assist in creating grip force, forearm muscle activity generally decreased. These results provide strategies for reducing forearm muscle loading in the workplace. STATEMENT OF RELEVANCE: Tools and tasks designed to take advantage of coupling grip with push or pull actions may be beneficial in reducing stress and injury in the muscles of the forearm. These factors should be considered in assessing the workplace in terms of acute and cumulative loading.

  4. Algorithm design for grip-pattern verification in smart gun

    NARCIS (Netherlands)

    Shang, X.; Veldhuis, R.N.J.; Bazen, A.M.; Ganzevoort, W.P.T.

    2005-01-01

    The Secure Grip project1 focuses on the development of a hand-grip pattern recognition system, as part of the smart gun. Its target customer is the police. To explore the authentication performance of this system, we collected data from a group of police officers, and made authentication simulations

  5. Biometric verification based on grip-pattern recognition

    NARCIS (Netherlands)

    Veldhuis, Raymond; Bazen, Asker; Kauffman, Joost; Hartel, Pieter

    2004-01-01

    This paper describes the design, implementation and evaluation of a user-verification system for a smart gun, which is based on grip-pattern recognition. An existing pressure sensor consisting of an array of 44 £ 44 piezoresistive elements is used to measure the grip pattern. An interface has been d

  6. Biometric verification based on grip-pattern recognition

    NARCIS (Netherlands)

    Veldhuis, Raymond N.J.; Bazen, A.M.; Kauffman, J.A.; Hartel, Pieter H.; Delp, Edward J.; Wong, Ping W.

    This paper describes the design, implementation and evaluation of a user-verification system for a smart gun, which is based on grip-pattern recognition. An existing pressure sensor consisting of an array of 44 x 44 piezoresistive elements is used to measure the grip pattern. An interface has been

  7. Algorithm Design for Grip-Pattern Verification in Smart Gun

    NARCIS (Netherlands)

    Shang, X.; Veldhuis, Raymond N.J.; Bazen, A.M.; Ganzevoort, W.P.T.

    2005-01-01

    The Secure Grip project1 focuses on the development of a hand-grip pattern recognition system, as part of the smart gun. Its target customer is the police. To explore the authentication performance of this system, we collected data from a group of police officers, and made authentication simulations

  8. Grip-pattern recognition: Applied to a smart gun

    NARCIS (Netherlands)

    Shang, X.

    2008-01-01

    In our work the verification performance of a biometric recognition system based on grip patterns, as part of a smart gun for use by the police ocers, has been investigated. The biometric features are extracted from a two-dimensional pattern of the pressure, exerted on the grip of a gun by the hand

  9. Grip-pattern verification for a smart gun

    NARCIS (Netherlands)

    Shang, X.; Groenland, J.P.J.; Groenland, J.P.J.; Veldhuis, Raymond N.J.

    In the biometric verification system of a smart gun, the rightful user of the gun is recognized based on grip-pattern recognition. It was found that the verification performance of grip-pattern recognition degrades strongly when the data for training and testing the classifier, respectively, have

  10. Study on the collision-mechanical properties of tomatoes gripped by ...

    African Journals Online (AJOL)

    STORAGESEVER

    2009-12-15

    Dec 15, 2009 ... The data of collision-mechanical property of tomatoes gripped by robot fingers are important for the gripping control of .... Figure 2a shows the process of robot fingers gripping tomato. ..... Drop test simulation of a sample.

  11. Improved Friction Joint With Self-Locking Grips

    DEFF Research Database (Denmark)

    Costache, Andrei; Glejbøl, Kristian; Sivebæk, Ion Marius

    2016-01-01

    Flexible risers are used in the oil industry to transport liquids and gas from the seafloorto extraction and production equipment at the sea surface. Ongoing research aims at using composite materials instead of steel, in order to reduce weight and increase stiffness. Ensuring an optimal load...... transfer between the composite and metal components is very important. This paper presents an improved method for anchoring a flat fiber reinforced tendon using a double grip system with self-locking grips. The novelty is the combination of new experimental results and finite element (FE) analysis...... to develop asuperior dry friction grip. Experimental results are carried using a dedicated test setup, through which the test parameters can be accurately controlled. The efficiency of the grip system during pullout is superior to results obtained with flat grips. Numerical results offer an in...

  12. Acute effect of different stretching methods on isometric muscle strength

    OpenAIRE

    Gabriel Vasconcellos de Lima Costa e Silva; Anderson Luiz Bezerra da Silveira; Fabrízio Di Masi; Cláudio Melibeu Bentes; Maria do Socorro Cirilo de Sousa; Jefferson da Silva Novaes

    2014-01-01

    http://dx.doi.org/10.4025/actascihealthsci.v36i1.15581 This study investigated the acute effect of static stretching methods (SS) and proprioceptive neuromuscular facilitation (PNF) on the static muscle strength (SMS). Eleven young male subjects with strength training experience, performed 3 tests with a 48h interval between them, randomly selected, where each one subject carried out all procedures: a) hand grip without stretching; b) hand grip preceded by static stretching of wrist flexor...

  13. Direct observation of photoinduced bent nitrosyl excited-state complexes

    Energy Technology Data Exchange (ETDEWEB)

    Sawyer, Karma R.; Steele, Ryan P.; Glascoe, Elizabeth A.; Cahoon, James F.; Schlegel, Jacob P.; Head-Gordon, Martin; Harris, Charles B.

    2008-06-28

    Ground state structures with side-on nitrosyl ({eta}{sup 2}-NO) and isonitrosyl (ON) ligands have been observed in a variety of transition-metal complexes. In contrast, excited state structures with bent-NO ligands have been proposed for years but never directly observed. Here we use picosecond time-resolved infrared spectroscopy and density functional theory (DFT) modeling to study the photochemistry of Co(CO){sub 3}(NO), a model transition-metal-NO compound. Surprisingly, we have observed no evidence for ON and {eta}{sup 2}-NO structural isomers, but have observed two bent-NO complexes. DFT modeling of the ground and excited state potentials indicates that the bent-NO complexes correspond to triplet excited states. Photolysis of Co(CO){sub 3}(NO) with a 400-nm pump pulse leads to population of a manifold of excited states which decay to form an excited state triplet bent-NO complex within 1 ps. This structure relaxes to the ground triplet state in ca. 350 ps to form a second bent-NO structure.

  14. Early reduction in toe flexor strength is associated with physical activity in elderly men

    Science.gov (United States)

    Suwa, Masataka; Imoto, Takayuki; Kida, Akira; Yokochi, Takashi

    2016-01-01

    [Purpose] To compare the toe flexor, hand grip and knee extensor strengths of young and elderly men, and to examine the association between toe flexor strength and physical activity or inactivity levels. [Subjects and Methods] Young (n=155, 18–23 years) and elderly (n=60, 65–88 years) men participated in this study. Toe flexor, hand grip, and knee extensor strength were measured. Physical activity (time spent standing/walking per day) and inactivity (time spent sitting per day) were assessed using a self-administered questionnaire. [Results] Toe flexor, hand grip, and knee extensor strength of the elderly men were significantly lower than those of the young men. Standing/walking and sitting times of the elderly men were lower than those of the young men. Toe flexor strength correlated with hand grip and knee extensor strength in both groups. In elderly men, toe flexor strength correlated with standing/walking time. In comparison to the young men’s mean values, toe flexor strength was significantly lower than knee extensor and hand grip strength in the elderly group. [Conclusion] The results suggest that age-related reduction in toe flexor strength is greater than those of hand grip and knee extensor strengths. An early loss of toe flexor strength is likely associated with reduced physical activity in elderly men. PMID:27313353

  15. Proton extraction from the CERN SPS using bent silicon crystals

    Science.gov (United States)

    Elsener, K.; Fidecaro, G.; Gyr, M.; Herr, W.; Klem, J.; Mikkelsen, U.; Møller, S. P.; Uggerhøj, E.; Vuagnin, G.; Weisse, E.

    1996-10-01

    The extraction of high energy particles from a circular accelerator by means of channeling in bent crystals is an attractive alternative to classical extraction schemes, in particular for high energy proton colliders where a classical scheme becomes expensive and incompatible with normal operation. This paper reviews the ongoing extraction experiments at the CERN-SPS with bent silicon crystals. It describes the principles of beam extraction by means of a bent crystal and the different extraction schemes used: first- and multi-pass extraction and the methods to create diffusion. The limitations in tuning the accelerator to the desired impact parameters and crucial items concerning crystal preparation, bending and pre-alignment are discussed. The experimental procedures including an overview of the detection of circulating and extracted beam are given. Finally, the paper summarizes the results of these experiments together with ideas for future developments.

  16. Recent progress on the mechanics of sharply bent DNA

    Science.gov (United States)

    Cong, PeiWen; Yan, Jie

    2016-08-01

    Despite extensive studies on the mechanics of DNA under external constrains, such as tension, torsion, and bending, several important aspects have remained poorly understood. One biologically important example is the mechanics of DNA under sharp bending conditions, which has been debated for a decade without thorough comprehension. The debate is about the interesting phenomenon raised from a series of different experiments: sharply bent DNA has a surprisingly high apparent bending flexibility that deviates from the canonical bending elasticity of DNA. This finding has motivated various theoretical models, which mainly incorporate the excitation of mechanical defects inside severely bent DNA molecules. Here, we review the recent progress on the understanding of the mechanics of sharply bent DNA and provide our view on this important question by interrogating the theoretical foundation of these experimental measurements.

  17. Energy transformation during erect and 'bent-hip, bent-knee' walking by humans with implications for the evolution of bipedalism.

    Science.gov (United States)

    Wang, W J; Crompton, R H; Li, Y; Gunther, M M

    2003-05-01

    We have previously reported that predictive dynamic modeling suggests that the 'bent-hip, bent-knee' gait, which some attribute to Australopithecus afarensis AL-288-1, would have been much more expensive in mechanical terms for this hominid than an upright gait. Normal walking by modern adult humans owes much of its efficiency to conservation of energy by transformation between its potential and kinetic states. These findings suggest the question if, and to what extent, energy transformation exists in 'bent-hip, bent-knee' gait. This study calculates energy transformation in humans walking upright, at three different speeds, and walking 'bent-hip, bent-knee'. Kinematic data were gathered from video sequences and kinetic (ground reaction force) data from synchronous forceplate measurement. Applying Newtonian mechanics to our experimental data, the fluctuations of kinetic and potential energy in the body centre of mass were obtained and the effects of energy transformation evaluated and compared. In erect walking the fluctuations of two forms of energy are indeed largely out-of-phase, so that energy transformation occurs and total energy is conserved. In 'bent-hip, bent-knee' walking, however, the fluctuations of the kinetic and potential energy are much more in-phase, so that energy transformation occurs to a much lesser extent. Among all modes of walking the highest energy recovery is obtained in subjectively 'comfortable' walking, the next highest in subjectively 'fast' or 'slow' walking, and the least lowest in 'bent-hip, bent-knee' walking. The results imply that if 'bent-hip, bent-knee' gait was indeed habitually practiced by early bipedal hominids, a very substantial (and in our view as yet unidentified) selective advantage would have had to accrue, to offset the selective disadvantages of 'bent-hip, bent-knee' gait in terms of energy transformation.

  18. Proximal arm kinematics affect grip force-load force coordination.

    Science.gov (United States)

    Vermillion, Billy C; Lum, Peter S; Lee, Sang Wook

    2015-10-01

    During object manipulation, grip force is coordinated with load force, which is primarily determined by object kinematics. Proximal arm kinematics may affect grip force control, as proximal segment motion could affect control of distal hand muscles via biomechanical and/or neural pathways. The aim of this study was to investigate the impact of proximal kinematics on grip force modulation during object manipulation. Fifteen subjects performed three vertical lifting tasks that involved distinct proximal kinematics (elbow/shoulder), but resulted in similar end-point (hand) trajectories. While temporal coordination of grip and load forces remained similar across the tasks, proximal kinematics significantly affected the grip force-to-load force ratio (P = 0.042), intrinsic finger muscle activation (P = 0.045), and flexor-extensor ratio (P muscles and the elbow joint cannot fully explain the observed changes, as task-related changes in intrinsic hand muscle activation were greater than in extrinsic hand muscles. Rather, between-task variation in grip force (highest during task 3) appears to contrast to that in shoulder joint velocity/acceleration (lowest during task 3). These results suggest that complex neural coupling between the distal and proximal upper extremity musculature may affect grip force control during movements, also indicated by task-related changes in intermuscular coherence of muscle pairs, including intrinsic finger muscles. Furthermore, examination of the fingertip force showed that the human motor system may attempt to reduce variability in task-relevant motor output (grip force-to-load force ratio), while allowing larger fluctuations in output less relevant to task goal (shear force-to-grip force ratio).

  19. Proofs of two conjectures on ternary weakly regular bent functions

    OpenAIRE

    Helleseth, Tor; Hollmann, Henk D. L.; Kholosha, Alexander; Wang, Zeying; Xiang, Qing

    2008-01-01

    We study ternary monomial functions of the form $f(x)=\\Tr_n(ax^d)$, where $x\\in \\Ff_{3^n}$ and $\\Tr_n: \\Ff_{3^n}\\to \\Ff_3$ is the absolute trace function. Using a lemma of Hou \\cite{hou}, Stickelberger's theorem on Gauss sums, and certain ternary weight inequalities, we show that certain ternary monomial functions arising from \\cite{hk1} are weakly regular bent, settling a conjecture of Helleseth and Kholosha \\cite{hk1}. We also prove that the Coulter-Matthews bent functions are weakly regular.

  20. Dispersion in a bent-solenoid channel with symmetric focusing

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Chun-xi [Argonne National Lab. (ANL), Argonne, IL (United States)

    2001-08-21

    Longitudinal ionization cooling of a muon beam is essential for muon colliders and will be useful for neutrino factories. Bent-solenoid channels with symmetric focusing has been considered for beam focusing and for generating the required dispersion in the ``emittance exchange'' scheme of longitudinal cooling. In this paper, we derive the Hamiltonian that governs the linear beam dynamics of a bent-solenoid channel, solve the single-particle dynamics, and give equations for determining the lattice functions, in particular, the dispersion functions.

  1. Power grip, pinch grip, manual muscle testing or thenar atrophy – which should be assessed as a motor outcome after carpal tunnel decompression? A systematic review

    Directory of Open Access Journals (Sweden)

    Kale Swati

    2007-11-01

    Full Text Available Abstract Background Objective assessment of motor function is frequently used to evaluate outcome after surgical treatment of carpal tunnel syndrome (CTS. However a range of outcome measures are used and there appears to be no consensus on which measure of motor function effectively captures change. The purpose of this systematic review was to identify the methods used to assess motor function in randomized controlled trials of surgical interventions for CTS. A secondary aim was to evaluate which instruments reflect clinical change and are psychometrically robust. Methods The bibliographic databases Medline, AMED and CINAHL were searched for randomized controlled trials of surgical interventions for CTS. Data on instruments used, methods of assessment and results of tests of motor function was extracted by two independent reviewers. Results Twenty-two studies were retrieved which included performance based assessments of motor function. Nineteen studies assessed power grip dynamometry, fourteen studies used both power and pinch grip dynamometry, eight used manual muscle testing and five assessed the presence or absence of thenar atrophy. Several studies used multiple tests of motor function. Two studies included both power and pinch strength and reported descriptive statistics enabling calculation of effect sizes to compare the relative responsiveness of grip and pinch strength within study samples. The study findings suggest that tip pinch is more responsive than lateral pinch or power grip up to 12 weeks following surgery for CTS. Conclusion Although used most frequently and known to be reliable, power and key pinch dynamometry are not the most valid or responsive tools for assessing motor outcome up to 12 weeks following surgery for CTS. Tip pinch dynamometry more specifically targets the thenar musculature and appears to be more responsive. Manual muscle testing, which in theory is most specific to the thenar musculature, may be more

  2. Autism Severity and Muscle Strength: A Correlation Analysis

    Science.gov (United States)

    Kern, Janet K.; Geier, David A.; Adams, James B.; Troutman, Melissa R.; Davis, Georgia; King, Paul G.; Young, John L.; Geier, Mark R.

    2011-01-01

    The current study examined the relationship between muscle strength, as measured by hand grip strength, and autism severity, as measured by the Childhood Autism Rating Scale (CARS). Thirty-seven (37) children with a diagnosis of autism spectrum disorder (ASD) were evaluated using the CARS and then tested for hand muscle strength using a hand grip…

  3. I/O correlation properties of bent functions

    Institute of Scientific and Technical Information of China (English)

    张宝东; 吕述望

    2000-01-01

    Let f( x1, x2, …, xn) be a Boolean bent function with n variables. The mutual information between the output variable and m linearly independent affine functions with respect to x1, x2, …, xn is studied. The results show that the mutual information depends mainly on m and n, but little on the structure of function f.

  4. Proton extraction from the SPS with a bent crystal

    Science.gov (United States)

    Ferroni, F.; Akbari, H.; Altuna, X.; Bardin, S.; Bellazzini, R.; Biryukov, V.; Brez, A.; Bussa, M. P.; Busso, L.; Calcaterra, A.; Carboni, G.; Costantini, F.; De Sangro, R.; Elsener, K.; Ferioli, G.; Ferrari, A.; Ferri, G. P.; Ferroni, F.; Fidecaro, G.; Freund, A.; Guinand, R.; Gyr, M.; Herr, W.; Hilaire, A.; Jensen, B. N.; Klem, J.; Lanceri, L.; Maier, K.; Massai, M. M.; Mertens, V.; Moller, S. P.; Morganti, S.; Palamara, O.; Peraire, S.; Petrera, S.; Placidi, M.; Santacesaria, R.; Scandale, W.; Schmidt, R.; Taratin, A. M.; Tosello, F.; Uggerhoj, E.; Vetterman, B.; Vita, P. E.; Vuagnin, G.; Weisse, E.; Weisz, S.; RD22 Collaboration

    1994-11-01

    The RD22 Collaboration has performed several measurements on the extraction of protons from the CERN-SPS by planar channeling in bent silicon monocrystals. Extraction efficiencies of about 10% have been routinely achieved for a bending angle of 8.5 mrad with the SPS running at 120 GeV.

  5. Effect of syllable articulation on precision and power grip performance.

    Directory of Open Access Journals (Sweden)

    Lari Vainio

    Full Text Available The present study was motivated by a theory, which proposes that speech includes articulatory gestures that are connected to particular hand actions. We hypothesized that certain articulatory gestures would be more associated with the precision grip than with the power grip, and vice versa. In the study, the participants pronounced a syllable and performed simultaneously a precision or power grip that was theorized to be either congruent or incongruent with the syllable. Relatively fast precision grip responses were associated with articulatory gestures in which the tip of the tongue contacted the alveolar ridge ([te] or the aperture of the vocal tract remained small ([hi], as well as gestures that required lip protrusion ([pu]. In contrast, relatively fast power grip responses were associated with gestures that were produced by moving the back of the tongue against the velum ([ke] or in which the aperture of the vocal tract remained large ([hα]. In addition to demonstrating that certain articulatory gestures are systematically connected to different grip types, the study may shed some light on discussion concerning sound symbolism and evolution of speech.

  6. Calamitic Smectic A-Polar Smectic APA Transition Observed in Bent Molecules with Large Bent-Angle Central Core of 4,6-Dichlorobenzene and Alkylthio Terminal Tail

    Science.gov (United States)

    Nguyen, Ha; Kang, Sungmin; Tokita, Masatoshi; Watanabe, Junji

    2011-07-01

    New homologs of bent molecules with a large bent-angle central core of 4,6-dichloro benzene and an alkylthio terminal tail have been synthesized. Although the corresponding alkoxy-tail homologs show only the calamitic phases because of its large bent angles around 160°, the new homologs with an alkylthio tail exhibit the antiferroelectric smectic APA (SmAPA) banana phase that is transformed on cooling from the calamitic smectic A (SmA) phase. The biaxial polar packing of bent molecules in the SmAPA phase is considered to arise from the hindered rotation around the molecular long axis due to the expansion of the mesophase temperatures to a lower temperature region. This study indicates that the bent molecules, even with a large bent angle, have the potential to form a switchable banana phase with a remarkable decrease in its phase temperature range to around 60 °C.

  7. Grip op werkstress. Mindfulness ontstresst maatschappelijk werkers

    Directory of Open Access Journals (Sweden)

    Jen van Horen

    2014-03-01

    Full Text Available Taking control over work related stress. Mindfulness destresses social workersStress is a major social problem. Due to the increasing workload and the content of the work, social workers are at risk to develop stress (symptoms. The physical and psychological consequences of prolonged stress are serious. By living healthy, optimize working conditions and applying mindfulness, stress can be reduced. Mindfulness is an effective and useful way to reduce stress. It increases the resistance of workers against stress, improves brainfunctions and therefore has a positive effect on the performance. These effects are great, but they are still weakly methodologically substantiated. A pilot project within the youthcare though, was enthusiastically received and proves to be effective against stress symptoms. The exercises that are part of this pilot fit well with the needs of employees. For organizations mindfulnesstrainings are a time-and cost-effective way of structural stress prevention.Grip op werkstress. Mindfulness ontstresst maatschappelijk werkersStress is een omvangrijk maatschappelijk probleem. Door de toenemende werkdruk en de inhoud van het werk zijn maatschappelijk werkers een risicogroep om stress en stressklachten te ontwikkelen. De fysieke en psychische gevolgen die langdurige stress met zich meebrengt zijn ernstig. Door gezond te leven, de arbeidsomstandigheden te optimaliseren en mindfulness toe te passen kan stress terug worden gedrongen. Mindfulness is een effectieve en bruikbare manier om stress te verminderen. Het vergroot de weerbaarheid van werknemers tegen stress, het verbetert de hersenwerking en heeft daardoor een positief effect op het functioneren. Grote effecten dus, maar wel nog methodologisch zwak onderbouwd. Een pilot binnen de jeugdzorg op het gebied van mindfulness is enthousiast ontvangen en blijkt effectief tegen stressklachten. De oefeningen die onderdeel uitmaken van deze pilot sluiten goed aan bij de behoeften van

  8. Bent Dinuclear Platinum(II Halo-Bridged Carbonyl Complexes

    Directory of Open Access Journals (Sweden)

    Fabio Marchetti

    2011-07-01

    Full Text Available Crystals of trans-Pt2(μ-X2X2(CO2 (X = Br, I have been grown and their molecular and crystalline structures have been solved by X-ray diffraction methods. In both cases the dinuclear molecules are bent, with a bending angle of 164.6° and 156.5° for the bromide and the iodide, respectively. While the structure of the bromo-derivative is reported here for the first time, a modification of trans-Pt2(μ-I2I2(CO2 with planar centrosymmetric molecules is known. This appears to be a rare case of a platinum(II halo-bridged derivative structurally characterized in both bent and planar forms.

  9. Measurement of the intermodal crosstalk of a bent multimode waveguide.

    Science.gov (United States)

    Wang, Jian; Zhao, Changyun; Wei, Bing; Gencheng, Wang; Dai, Tingge; Wang, Yuehai; Jiang, Xiaoqing; Li, Yubo; Yang, Jianyi

    2016-09-20

    We quantitatively investigate the main source of the intermodal crosstalk of a silicon-based bent multimode waveguide by experiment. The measurement is performed through time-domain scanning low-coherence interferometry. From the measurement results, one can not only calculate the modal crosstalk, but can also locate the position where the crosstalk appears. The results indicate that the modal mismatch at the points where the curvature of the waveguide changes is the main origin of the modal crosstalk. For a two-mode waveguide with a bending radius of 5 μm at 1310 nm, the crosstalk is as high as -20 and -16  dB for the fundamental and first-order mode, respectively. This work gives us a deep insight into how the guided modes actually propagate through the bent waveguide.

  10. Simulations of electron channeling in bent silicon crystal

    CERN Document Server

    Sushko, G B; Korol, A V; Greiner, Walter; Solov'yov, A V; Polozkov, R G; Ivanov, V K

    2013-01-01

    We report on the results of theoretical simulations of the electron channeling in a bent silicon crystal. The dynamics of ultra-relativistic electrons in the crystal is computed using the newly developed part [1] of the MBN Explorer package [2,3], which simulates classical trajectories of in a crystalline medium by integrating the relativistic equations of motion with account for the interaction between the projectile and crystal atoms. A Monte Carlo approach is employed to sample the incoming electrons and to account for thermal vibrations of the crystal atoms. The electron channeling along Si(110) crystallographic planes are studied for the projectile energies 195--855 MeV and different curvatures of the bent crystal.

  11. Vertical neutron beam focusing with bent mosaic crystals

    Science.gov (United States)

    Courtois, P.

    2016-09-01

    We report on the performance of bent mosaic crystals when used as a vertical focusing neutron monochromator. High-quality Cu(200) and Ge(335) mosaic crystals with a controlled curvature have been successfully produced at the ILL using plastic deformation at high temperature. As expected from simple geometrical considerations, they exhibit excellent properties for focusing a neutron beam vertically when examined on a high-resolution diffractometer installed on an m = 1 thermal neutron guide. Both Cu(200) and Ge(335) curved crystals allow a significant reduction of the focal image size at the sample position compared with a flat crystal with the same defect concentration. As a result, significant gain factors of 6 to 7 in intensity were obtained by replacing a flat crystal of 30 mm with a bent crystal.

  12. Manipulation of hadron beams with bent crystals in circular accelerators

    CERN Document Server

    Rossi, R; Redaelli, S; Scandale, W

    2016-01-01

    Over the past years the understanding and use of coherent interactions of charged particles with ordered crystal lattices has achieved excellent results. Improving collimation of hadron beams in circular accelerators, like the Large Hadron Collider (LHC) of the European Council for Nuclear Research (CERN), it is one of the possible applications. The aim of the UA9 experiment is to demonstrate the feasibility of a two-stage collimation system in the CERN-SPS : the first stage is a bent crystal oriented for an optimal channeling of the incoming halo particles; the second stage is a massive absorber. Two crystals were installed in the LHC last year and a test of crystal assisted collimation at the highest energy will be possible as early as 2015. Finally, the UA9 Collaboration is investigating extraction of particles from a circular accelerator, based on bent crystals.

  13. Genetic Analysis on Bent Characters of Cucumber Fruit

    Institute of Scientific and Technical Information of China (English)

    ZHANG Peng; QIN Zhiwei; WANG Lili; ZHOU Xiuyan

    2011-01-01

    Bent varieties and straight varieties were made as parents for the genetic analysis to investigate cucumber bending genetic mechanism. The results showed that the bent characters of the cucumber fruit (BCCF) were quantitative inheritance controlled by multiple genes and major genes. The additive effect played the main role and the dominance effect played the lesser role. Compared with the additive environmental variance, the dominant-environmental variance was more important and the cucumber fruit was more easily affected by the additive effect. The broad heritability and the narrow heritability of BCCF were both higher. The varieties of D0455 and D07299 could be used as parents which were benefit for improving the straight characters of the cucumber fruit

  14. Advanced Bent Crystal Collimation Studies at the Tevatron (T-980)

    CERN Document Server

    Zvoda, V; Carrigan, R; Drozhdin, A; Johnson, T; Kwan, S; Mokhov, N; Prosser, A; Reilly, R; Uplegger, R Rivera L; Shiltsev, V; Still, D; Zagel, J; Guidi, V; Bagli, E; Mazzolari, A; Ivanov, Yu; Chesnokov, Yu; Yazynin, I

    2011-01-01

    The T-980 bent crystal collimation experiment at the Tevatron has recently acquired substantial enhancements. First, two new crystals - a 16-strip one manufactured and characterized by the INFN Ferrara group and a quasi-mosaic crystal manufactured and characterized by the PNPI group. Second, a two plane telescope with 3 high-resolution pixel detectors per plane along with corresponding mechanics, electronics, control and software has been manufactured, tested and installed in the E0 crystal region. The purpose of the pixel telescope is to measure and image channeled (CH), volume-reflected (VR) and multiple volume-reflected (MVR) beam profiles produced by bent crystals. Third, an ORIGIN-based system has been developed for thorough analysis of experimental and simulation data. Results of analysis are presented for different types of crystals used from 2005 to present for channeling and volume reflection including pioneering tests of two-plane crystal collimation at the collider, all in comparison with detailed ...

  15. Revisit the anomalous bending elasticity of sharply bent DNA

    CERN Document Server

    Cong, Peiwen; Chen, Hu; van der Maarel, Johan R C; Doyle, Patrick S; Yan, Jie

    2015-01-01

    Several recent experiments have suggested that sharply bent DNA has a surprisingly high bending flexibility, but the cause is poorly understood. It has been demonstrated that excitation of flexible defects can explain the results; while whether such defects can be excited under the level of DNA bending in those experiments has remained unclear and been debated. Interestingly, due to experimental design DNA contained pre-existing nicks in nearly all those experiments, while the potential effect of nicks have never been considered. Here, using full-atom molecular dynamics (MD) simulations, we show that nicks promote DNA basepair disruption at the nicked sites which drastically reduced DNA bending energy. In the absence of nicks, basepair disruption can also occur, but it requires a higher level of DNA bending. Overall, our results challenge the interpretations of previous sharp DNA bending experiments and highlight that the micromechanics of sharply bent DNA still remains an open question.

  16. Individual finger contribution in submaximal voluntary contraction of gripping.

    Science.gov (United States)

    Kong, Yong-Ku; Lee, Kyung-Sun; Kim, Dae-Min; Jung, Myung-Chul

    2011-11-01

    The objective of this study was to evaluate individual finger force and contribution to a gripping force, the difference between actual and expected finger forces and subjective discomfort rating at 10 different submaximal voluntary contraction (%MVC) levels (10-100% in 10 increments). Seventy-two participants randomly exerted gripping force with a multi-finger force measurement system. The individual finger force, gripping force and discomfort increased as %MVC levels increased. The middle and ring fingers exerted more force and contributed to a gripping force more than the index and little fingers due to their larger mass fractions of the digit flexor muscles. It was apparent at MVC; however, the index finger increased its contribution and exerted even more force than expected at more than 50% MVC. Subjective discomfort supported the results of the objective measures. This could explain the conflicting findings between index and ring fingers in previous finger contribution studies. STATEMENT OF RELEVANCE: Hand tool design is of special interest in ergonomics due to its association with musculoskeletal disorders in the hand. This study reveals a different contribution pattern of the fingers in submaximal voluntary contraction of gripping exertion.

  17. Volume reflection efficiency for negative particles in bent crystals

    Science.gov (United States)

    Biryukov, V. M.

    2017-02-01

    We suggest a formula for the efficiency of a single volume reflection of negatively charged particles in bent crystal planes and compare it to recent experiments at SLAC, MAMI and CERN with electrons and negative pions in the energy range from 0.855 to 150 GeV in Si crystals. We show that Lindhard reversibility rule provides sufficient basis for quantitative understanding of these experiments.

  18. Volume reflection efficiency for negative particles in bent crystals

    Directory of Open Access Journals (Sweden)

    V.M. Biryukov

    2017-02-01

    Full Text Available We suggest a formula for the efficiency of a single volume reflection of negatively charged particles in bent crystal planes and compare it to recent experiments at SLAC, MAMI and CERN with electrons and negative pions in the energy range from 0.855 to 150 GeV in Si crystals. We show that Lindhard reversibility rule provides sufficient basis for quantitative understanding of these experiments.

  19. Bent versus straight tips in micropulsed longitudinal phacoemulsification.

    Science.gov (United States)

    Stagg, Brian C; Gupta, Isha; Cahoon, Judd; Ronquillo, Cecinio; Shi, Dallas; Zaugg, Brian; Gardiner, Gareth; Barlow, William R; Pettey, Jeff H; Aabid Farukhi, M; Jensen, Jason; Olson, Randall J

    2015-10-01

    The aim of this study was to evaluate bent and straight phacoemulsification tips to determine which tip is more efficient in removal of lens fragments, using micropulsed longitudinal ultrasound in phacoemulsification. In vitro laboratory study. The John A. Moran Eye Center Laboratories, University of Utah, Salt Lake City, Utah, was the study setting. Pig lenses hardened in a manner comparable with dense human cataracts were cut into 2-mm cubes and removed with micropulsed longitudinal ultrasound using settings previously shown to be optimally efficient (6 milliseconds on and 6 milliseconds off for a bent tip). To verify this time as most efficient for a straight tip, we also tested times of 5, 6, and 7 milliseconds time on and off. The tips were either straight or with a 20-degree bend. Twenty cubes were used for each comparative run. For the straight tip, 6 milliseconds on (1.56 ± 0.815 seconds) was significantly more efficient than 7 milliseconds on (2.45 ± 1.56 seconds, p = 0.001) and not significantly more efficient than 5 milliseconds on (1.69 ± 0.86 seconds, p = 0.43). Five milliseconds off time (1.45 ± 0.76s) was more efficient than 6 milliseconds (2.06 ± 1.37 seconds, p = 0.004) and 7 milliseconds off (2.18 ± 1.24s, p = 0.001). The straight tip was more efficient than the bent tip (1.38 ± 0.83 versus 2.93 ± 2.14 seconds, p = 0.006). Results are contrary to accepted common belief. Micropulsed longitudinal phacoemulsification is more efficient with a straight rather than a bent tip. Copyright © 2015 Canadian Ophthalmological Society. Published by Elsevier Inc. All rights reserved.

  20. Ram pressure statistics for bent tail radio galaxies

    CERN Document Server

    Mguda, Zolile; van der Heyden, Kurt; Gottlöber, Stefan; Cress, Catherine; Vaisanen, Petri; Yepes, Gustavo

    2014-01-01

    In this paper we use the MareNostrum Universe Simulation, a large scale, hydrodynamic, non-radiative simulation in combination with a simple abundance matching approach to determine the ram pressure statistics for bent radio sources (BRSs). The abundance matching approach allows us to determine the locations of all galaxies with stellar masses $> 10^{11} MSol$ in the simulation volume. Assuming ram pressure exceeding a critical value causes bent morphology, we compute the ratio of all galaxies exceeding the ram pressure limit (RPEX galaxies) relative to all galaxies in our sample. According to our model 50% of the RPEX galaxies at $z = 0$ are found in clusters with masses larger than $10^{14.5}MSol$ the other half resides in lower mass clusters. Therefore, the appearance of bent tail morphology alone does not put tight constraints on the host cluster mass. In low mass clusters, $M 10^{15}Msol$ they can be found at distances up to 1.5Mpc. Only clusters with masses $> 10^{15}MSol $ are likely to host more than...

  1. Effects of Anodal Transcranial Direct Current Stimulation on Visually Guided Learning of Grip Force Control

    Directory of Open Access Journals (Sweden)

    Tamas Minarik

    2015-03-01

    Full Text Available Anodal transcranial Direct Current Stimulation (tDCS has been shown to be an effective non-invasive brain stimulation method for improving cognitive and motor functioning in patients with neurological deficits. tDCS over motor cortex (M1, for instance, facilitates motor learning in stroke patients. However, the literature on anodal tDCS effects on motor learning in healthy participants is inconclusive, and the effects of tDCS on visuo-motor integration are not well understood. In the present study we examined whether tDCS over the contralateral motor cortex enhances learning of grip-force output in a visually guided feedback task in young and neurologically healthy volunteers. Twenty minutes of 1 mA anodal tDCS were applied over the primary motor cortex (M1 contralateral to the dominant (right hand, during the first half of a 40 min power-grip task. This task required the control of a visual signal by modulating the strength of the power-grip for six seconds per trial. Each participant completed a two-session sham-controlled crossover protocol. The stimulation conditions were counterbalanced across participants and the sessions were one week apart. Performance measures comprised time-on-target and target-deviation, and were calculated for the periods of stimulation (or sham and during the afterphase respectively. Statistical analyses revealed significant performance improvements over the stimulation and the afterphase, but this learning effect was not modulated by tDCS condition. This suggests that the form of visuomotor learning taking place in the present task was not sensitive to neurostimulation. These null effects, together with similar reports for other types of motor tasks, lead to the proposition that tDCS facilitation of motor learning might be restricted to cases or situations where the motor system is challenged, such as motor deficits, advanced age, or very high task demand.

  2. Study of Silicon Photomultipliers for the GRIPS Calorimeter Module

    Directory of Open Access Journals (Sweden)

    Alexei Ulyanov

    2013-01-01

    Full Text Available GRIPS is a proposed gamma-ray (200 keV to 80 MeV astronomy mission, which incorporates a pair-creation and Compton scattering telescope, along with X-ray and infrared telescopes. It will carry out a sensitive all-sky scanning survey, investigating phenomena such as gamma-ray bursts, blazars and core collapse supernovae. The main telescope is composed of a Si strip detector surroundedby a calorimeter with a fast scintillator material. We present the initial results of a study which considers the potential use of silicon photomultipliers in conjunction with the scintillator in the GRIPS calorimeter module.

  3. Synthesis and mesomorphic properties of bent-shaped molecule with low bent-angle central core and long alkylthio tail

    Institute of Scientific and Technical Information of China (English)

    Xiao Dong Li; Mao Sheng Zhan; Kai Wang

    2011-01-01

    Two homologous series of bent-shaped molecules composed of low bent-angle naphthalene central core and long alkoxy tail or alkylthio tail, N(1,7)-n-OPIMB and W(1,7)-n-SPIMB (n = 20, 22), respectively, were synthesized. The mesomorphic properties were investigated by differential scanning calorimetry (DSC), polarizing optical microscopy (POM) and X-ray diffraction (XRD). Compared to the direct transition from the isotropic phase to the chiral B4 phase examined in N(1,7)-n-OPIMB, N(1,7)-n-SPIMB exhibited a rare Iso-Ncol-Colh-B4 phase sequence. The combination of the asymmetric low bent-angle 1,7-naphathalene central core and the flexible long alkylthio tail is considered to play an important role in the formation of such a novel phase sequence. (c) 2011 Mao Sheng Zhan. Published by Elsevier B.V. on behalf of Chinese Chemical Society. All rights reserved.

  4. The administration and interpretation of the rapid exchange grip test: a national survey.

    Science.gov (United States)

    Shechtman, Orit; Goodall, Sara K

    2008-01-01

    The purpose of the present study was to determine if the administration and interpretation of the rapid exchange grip (REG) test vary among hand therapists nationally. The REG is used to determine sincerity of effort of grip strength. There are inconsistencies in the literature regarding the administration and interpretation of the REG, as various studies use different testing protocols and diverse interpretation criteria for what constitutes a sincere effort. As a result, we expected to find a lack of standardization in the administration and interpretation of the REG in clinical practice. We conducted a random nationwide survey of 200 hand therapists. The questionnaire items regarding the administration of the REG included patient position, test instructions, handle settings, handling of the dynamometer, hand switch rate, number of repetitions, and techniques used to record the score. The items for the interpretation of the REG involved questions regarding comparative tests. We found that the REG test lacks standardized administration protocols and interpretation criteria among therapists nationwide. The lack of standardization is likely to affect the reliability and validity of the REG and to hinder the therapist's ability to accurately report its outcomes. The implications of lack of standardization in assessment techniques to the profession are discussed.

  5. Gripped by movies: From story-world to artifact absorption

    NARCIS (Netherlands)

    Doicaru, M.M.

    2016-01-01

    That movies are a great source of entertainment seems to be common sense. But how exactly movies manage to get large audiences absorbed, or what is their gripping tool is still a mystery. Research makes use of different concepts pointing to narrative absorption, but it is not clear how they differ f

  6. Analysis of Circular Polarization of Cylindrically Bent Microstrip Antennas

    Directory of Open Access Journals (Sweden)

    Tiiti Kellomäki

    2012-01-01

    Full Text Available When circularly polarized (CP microstrip antennas are bent, the polarization becomes elliptical. We present a simple model that describes the phenomenon. The two linear modes present in a CP patch are modeled separately and added together to produce CP. Bending distorts the almost-spherical equiphase surface of a linearly polarized patch, which leads to phase imbalance in the far-field of a CP patch. The model predicts both the frequency shifting of the axial ratio band as well as the narrowing of the axial ratio beam. Uncontrolled bending is a problem associated especially with flexible textile antennas, and wearable antennas should therefore be designed somewhat conformal.

  7. Quantum effects for particles channeling in a bent crystal

    Science.gov (United States)

    Feranchuk, Ilya; San, Nguyen Quang

    2016-09-01

    Quantum mechanical theory for channeling of the relativistic charged particles in the bent crystals is considered in the paper. Quantum effects of under-barrier tunneling are essential when the radius of the curvature is closed to its critical value. In this case the wave functions of the quasi-stationary states corresponding to the particles captured in a channel are presented in the analytical form. The efficiency of channeling of the particles and their angular distribution at the exit crystal surface are calculated. Characteristic experimental parameters for observation the quantum effects are estimated.

  8. Riot at the calc exam and other mathematically bent stories

    CERN Document Server

    Adams, Colin

    2009-01-01

    What's so funny about math? Lots! Especially if you're mathematically bent. In the world of Colin Adams, differential equations bring on tears of laughter. Hollywood producers hire algebraic geometers to punch up a script. In this world, math and humor are synonymous. Riot at the Calc Exam is a proof of this fact. A collection of humorous math stories, this book gives a window into mathematics and the culture of mathematicians. Appropriate for mathematicians, math students, math teachers, lay people with an interest in mathematics, and indeed everyone else. This book is a romp through the wild

  9. Bent Branderup - akadeemilise ratsutamiskunsti rüütel / Eda Vallimäe

    Index Scriptorium Estoniae

    Vallimäe, Eda

    2014-01-01

    Taani ratusutamismeister Bent Branderup on ellu äratanud ajaloo- ja kultuuripärandit esindava akadeemilise ratsutamiskunsti, mis kombineerib parimad teadmised vanadelt ratsutamismeistritelt moodsa hobumaailmaga

  10. Acute effect of different stretching methods on isometric muscle strength

    Directory of Open Access Journals (Sweden)

    Gabriel Vasconcellos de Lima Costa e Silva

    2014-03-01

    This study investigated the acute effect of static stretching methods (SS and proprioceptive neuromuscular facilitation (PNF on the static muscle strength (SMS. Eleven young male subjects with strength training experience, performed 3 tests with a 48h interval between them, randomly selected, where each one subject carried out all procedures: a hand grip without stretching; b hand grip preceded by static stretching of wrist flexors muscles; c hand grip preceded by PNF stretching of wrist flexors muscles. The Shapiro-Wilk test verified the normality of data, and a one-way ANOVA with repeated measures, followed by Tukey’s post hoc test, evaluated the differences between the groups. The significance was set at p 0.05. In conclusion, both stretching methods had caused negative effects on isometric strength, reducing its levels.

  11. Planar channeling and quasichanneling oscillations in a bent crystal

    Energy Technology Data Exchange (ETDEWEB)

    Sytov, A.I. [Universita di Ferrara, Dipartimento di Fisica e Scienze della Terra, Ferrara (Italy); Belarusian State University, Research Institute for Nuclear Problems, Minsk (Belarus); INFN, Ferrara (Italy); Guidi, V.; Bagli, E.; Bandiera, L.; Germogli, G.; Mazzolari, A. [Universita di Ferrara, Dipartimento di Fisica e Scienze della Terra, Ferrara (Italy); INFN, Ferrara (Italy); Tikhomirov, V.V. [Belarusian State University, Research Institute for Nuclear Problems, Minsk (Belarus); INFN, Ferrara (Italy)

    2016-02-15

    Particles passing through a crystal under planar channeling are captured by a continuous potential and experience transverse oscillations in their motion. As channeled particles approach the atomic planes, they are likely to be dechanneled. This effect is being used in ion-beam analysis with MeV energy. We study this effect in a bent crystal for positive and negative particles within a wide range of energies in sight of application of such crystals at accelerators. We look for the conditions for the observation or not of channeling oscillations in the deflection angle distribution in experiments where the beam passes through the bent crystal. Indeed a new kind of oscillations in the deflection angle distribution, strictly related to the motion of over-barrier particles, i.e. quasichanneled particles, is predicted. Such oscillations, named planar quasichanneling oscillations, possess a different nature than channeling oscillations. Through computer simulation, we study this effect and provided a theoretical interpretation for them. We show that channeling oscillations can be observed only for positive particles while quasichanneling oscillations can exist for particles with either sign. The conditions for experimental observation of channeling and quasichanneling oscillations at existing accelerators with available crystal are found and optimized. (orig.)

  12. Direct numerical simulation of turbulence in a bent pipe

    Science.gov (United States)

    Schlatter, Philipp; Noorani, Azad

    2013-11-01

    A series of direct numerical simulations of turbulent flow in a bent pipe is presented. The setup employs periodic (cyclic) boundary conditions in the axial direction, leading to a nominally infinitely long pipe. The discretisation is based on the high-order spectral element method, using the code Nek5000. Four different curvatures, defined as the ratio between pipe radius and coil radius, are considered: κ = 0 (straight), 0.01 (mild curvature), 0.1 and 0.3 (strong curvature), at bulk Reynolds numbers of up to 11700 (corresponding to Reτ = 360 in the straight pipe case). The result show the turbulence-reducing effect of the curvature (similar to rotation), leading close to relaminarisation in the inner side; the outer side, however, remains fully turbulent. Prpoer orthogonal decomposition (POD) is used to extract the dominant modes, in an effort to explain low-frequency switching of sides inside the pipe. A number of additional interesting features are explored, which include sub-straight and sub-laminar drag for specific choices of curvature and Reynolds number: In particular the case with sub-laminar drag is investigated further, and our analysis shows the existence of a spanwise wave in the bent pipe, which in fact leads to lower overall pressure drop.

  13. The use of the rapid exchange grip test in detecting sincerity of effort, Part II: validity of the test.

    Science.gov (United States)

    Shechtman, O; Taylor, C

    2000-01-01

    The rapid exchange grip (REG) test was developed to identify patients exerting insincere effort. The premise of the REG test is that a maximal, sincere effort yields a "negative REG," in which peak static grip (SG) scores are greater than peak REG scores, and that a submaximal, insincere effort yields a "positive REG," in which REG scores are greater than SG scores. There is disagreement in the literature concerning what constitutes a positive REG test, suggesting that the REG may not be a valid measure of sincerity of effort. The purpose of the present study was to investigate the validity of the REG test by examining its premise as well as its sensitivity and specificity values. The 146 uninjured subjects performed a series of randomized grip strength tests, exerting both maximal and submaximal efforts. The tests included the REG at hand switch rates of 45 rpm (REG-45) and 60 rpm (REG-60), the maximal static grip test (MSGT), and the five-rung test (5R). Our findings supported the concept of a "negative REG" for both REG maneuvers and both comparative SG tests. The concept of a "positive REG," however, was supported only when peak REG scores were compared with peak 5R scores. The authors found relatively low sensitivity and specificity values, suggesting that the REG test may not be sensitive or specific enough to effectively detect sincerity of effort. The authors discuss the likelihood that mistakes will be made when the REG test is used to diagnose sincerity of effort and the possible consequences of making such mistakes.

  14. Analysis of the effects of hospitalization on fine hand functions compared to gross grip in patients with rheumatoid arthritis

    Directory of Open Access Journals (Sweden)

    Zeynep Tuna

    2015-09-01

    Full Text Available Objective: Hospitalization process causes a variety of physical problems. The decrease of hand use in daily life during hospitalization brings hand dysfunction to mind in inpatients. The aim of this study is to compare the hand functions of hospitalized patients with Rheumatoid Arthritis (RA to outpatients in detail. Methods: Grip and pinch strengths of both hospitalized patients in rheumatology service and outpatients on the routine control day were measured. In addition, 9-Hole Peg Test was performed and the disability level was determined by the Turkish version of Michigan Hand Outcomes Questionnaire (MHOQ. Results: While grip strength and MHOQ scores were similar (p>0.05 in both groups, all three pinch strengths (lateral, bipod, tripod and 9HPT scores were lower (p<0.05 in hospitalized patients. Conclusion: Consequently, besides disease activity, hospitalization process also impairs fine hand functions in rheumatological patients. Evaluation of fine hand functions and appropriate rehabilitative interventions may prevent further disability in hospitalized patients. J Clin Exp Invest 2015; 6 (3: 228-232

  15. Growth Diagrams for Individual Finger Strength in Children Measured with the RIHM

    NARCIS (Netherlands)

    H.M. Molenaar (Ties); R.W. Selles (Ruud); S.P. Willemsen (Sten); S.E.R. Hovius (Steven); H.J. Stam (Henk)

    2011-01-01

    textabstractBackground: Although grip and pinch strength provide a more global measure of a large number of digits and muscles, measuring strength of individual fingers or the thumb can provide additional and more detailed information regarding hand strength. Questions/purposes: We developed growth

  16. Locomotor and oculomotor impairment associated with cerebellar dysgenesis in Zic3-deficient (Bent tail) mutant mice.

    NARCIS (Netherlands)

    Aruga, J.; Ogura, H.; Shutoh, F.; Ogawa, M.; Franke, B.; Nagao, S.; Mikoshiba, K.

    2004-01-01

    We examined the adult neural phenotypes of the Bent tail mutant mouse. The Bent tail mutant mouse was recently shown to lack a submicroscopic part of the X chromosome containing the Zic3 gene, which encodes a zinc-finger protein controlling vertebrate neural development. While nearly one-fourth of

  17. 31 CFR 100.11 - Exchange of bent and partial coins.

    Science.gov (United States)

    2010-07-01

    ... 31 Money and Finance: Treasury 1 2010-07-01 2010-07-01 false Exchange of bent and partial coins. 100.11 Section 100.11 Money and Finance: Treasury Regulations Relating to Money and Finance EXCHANGE OF PAPER CURRENCY AND COIN Exchange of Coin § 100.11 Exchange of bent and partial coins....

  18. Technology transfer: taking science from the books to the ground at Bent Creek Experimental Forest

    Science.gov (United States)

    Julia Kirschman

    2014-01-01

    Technology transfer has been an important part of the research program at Bent Creek Experimental Forest (Bent Creek) since its establishment in 1925. Our stated mission is to develop and disseminate knowledge and strategies for restoring, managing, sustaining, and enhancing the vegetation and wildlife of upland hardwood-dominated forest ecosystems of the Southern...

  19. REGULAR METHOD FOR SYNTHESIS OF BASIC BENT-SQUARES OF RANDOM ORDER

    Directory of Open Access Journals (Sweden)

    A. V. Sokolov

    2016-01-01

    Full Text Available The paper is devoted to the class construction of the most non-linear Boolean bent-functions of any length N = 2k (k = 2, 4, 6…, on the basis of their spectral representation – Agievich bent squares. These perfect algebraic constructions are used as a basis to build many new cryptographic primitives, such as generators of pseudo-random key sequences, crypto graphic S-boxes, etc. Bent-functions also find their application in the construction of C-codes in the systems with code division multiple access (CDMA to provide the lowest possible value of Peak-to-Average Power Ratio (PAPR k = 1, as well as for the construction of error-correcting codes and systems of orthogonal biphasic signals. All the numerous applications of bent-functions relate to the theory of their synthesis. However, regular methods for complete class synthesis of bent-functions of any length N = 2k are currently unknown. The paper proposes a regular synthesis method for the basic Agievich bent squares of any order n, based on a regular operator of dyadic shift. Classification for a complete set of spectral vectors of lengths (l = 8, 16, … based on a criterion of the maximum absolute value and set of absolute values of spectral components has been carried out in the paper. It has been shown that any spectral vector can be a basis for building bent squares. Results of the synthesis for the Agievich bent squares of order n = 8 have been generalized and it has been revealed that there are only 3 basic bent squares for this order, while the other 5 can be obtained with help the operation of step-cyclic shift. All the basic bent squares of order n = 16 have been synthesized that allows to construct the bent-functions of length N = 256. The obtained basic bent squares can be used either for direct synthesis of bent-functions and their practical application or for further research in order to synthesize new structures of bent squares of orders n = 16, 32, 64, …

  20. Bent Telescopic Rods in Patients With Osteogenesis Imperfecta.

    Science.gov (United States)

    Lee, R Jay; Paloski, Michael D; Sponseller, Paul D; Leet, Arabella I

    2016-09-01

    Telescopic rods require alignment of 2 rods to enable lengthening. A telescopic rod converts functionally into a solid rod if either rod bends, preventing proper engagement. Our goal was to characterize implant bending as a mode of failure of telescopic rods used in the treatment of osteogenesis imperfecta in children. We conducted a retrospective review of our osteogenesis imperfecta database for patients treated with intramedullary telescopic rods at our institution from 1992 through 2010 and identified 12 patients with bent rods. The 6 boys and 6 girls had an average age at the time of initial surgery of 3.1 years (range, 1.8 to 8.3 y) and a total of 51 telescoping rods. Clinic notes, operative reports, and radiographs were reviewed. The rods were analyzed for amount of lengthening, characteristics of bending, presence of cut out, or disengagement from an anchor point. Bends in the rods were characterized by their location on the implant component. The bent and straight rods were compared. Data were analyzed with the Mann-Whitney test (statistical significance set at P≤0.05). Of the 51 telescoping rods, 17 constructs (33%) bent. The average interval between surgery and rod bending was 4.0 years (range, 0.9 to 8.2 y). Before bending, 11 of 17 telescoping rods had routine follow-up radiographs for review. In 10 of the rods, bending was present when early signs of rod failure were first detected. Rod bending did not seem to be related to rod size. There was no area on the rod itself that seemed more susceptible to bending. Rod bending can be an early sign of impending rod failure. When rod bending is first noted, it may predispose the rod to other subsequent failures such as loss of proximal and distal fixation and cut out. Rod bending should be viewed as an indicator for closer monitoring of the patient and discussions regarding future need for rod exchange. Level III-retrospective review.

  1. Association of BODE index to daily living activities and upper limb strength in chronic obstructive pulmonary disease

    Directory of Open Access Journals (Sweden)

    Renukadevi Mahadevan

    2015-01-01

    Full Text Available Context: Chronic obstructive pulmonary disease (COPD is a progressive disease that reduces the functional capacity and the ability to perform activities of daily living (ADL. Aims: To determine the correlation between the BODE index (B - body mass index; O - airflow obstruction; D - dyspnea; and E - exercise capacity with ADL and grip strength in COPD patients. Settings and Design: The study was conducted at JSS Hospital, Mysore. It was a correlational study. Subjects and Methods: Sixty-six COPD subjects were recruited by convenience sampling. Forced expiratory volume, body mass index, Six-Minute Walk Test, and Medical Research Council scale were assessed. The BODE index was calculated. The total score of London Chest Activities of Daily Living (LCADL and grip strength were compared between the patients of the four quartiles of the BODE index. The association between LCADL and grip Strength with BODE index was analyzed. Statistical Analysis: Eta coefficient, Spearman's rank correlation coefficient and the analysis of variance were used. Results: The Eta coefficients showed the strength or the measure of associations of BODE index with age, grip strength, and LCADL. Spearman's correlation coefficient shows that there is an inverse association with grip strength and LCADL, and it was statistically significant as theP<0.05. Conclusions: ADL limitation and hand grip strength test have a strong association with the BODE index in patients with moderate to severe COPD.

  2. Development of Exterior Anti-corrosion Coating Production Line for Large Diameter Hot Bent Pipes

    Institute of Scientific and Technical Information of China (English)

    JiaoRuyi; ZhangYing

    2004-01-01

    The epoxy powder exterior anti-corrosion coating production line for bent pipes with a single (double) course production is a technologically advanced bent pipe anti-corrosion method with cost efficiency, environment friendliness and stable coating quality. The quality of the coating on the bent pipe fully meets the requirements of the current national and industrial standards. The application of the technology has filled the gap in the bent pipe anti-corrosion coating area of China, and leads the world technologically. With this technology the coating quality of the bent pipe has greatly improved, resulting in significant social and economic benefits. With the use of the technology in various large scale pipeline projects such as the “West to East Gas Pipeline Project”, it will exhibite a greater potential in the future pipeline projects with a broad application prospect.

  3. GRIPS - Gamma-Ray Imaging, Polarimetry and Spectroscopy

    CERN Document Server

    Greiner, J; Aharonian, F; Ajello, M; Balasz, L G; Barbiellini, G; Bellazzini, R; Bishop, S; Bisnovatij-Kogan, G S; Boggs, S; Bykov, A; DiCocco, G; Diehl, R; Elsässer, D; Foley, S; Fransson, C; Gehrels, N; Hanlon, L; Hartmann, D; Hermsen, W; Hillebrandt, W; Hudec, R; Iyudin, A; Jose, J; Kadler, M; Kanbach, G; Klamra, W; Kiener, J; Klose, S; Kreykenbohm, I; Kuiper, L M; Kylafis, N; Labanti, C; Langanke, K; Langer, N; Larsson, S; Leibundgut, B; Laux, U; Longo, F; Maeda, K; Marcinkowski, R; Marisaldi, M; McBreen, B; McBreen, S; Meszaros, A; Nomoto, K; Pearce, M; Peer, A; Pian, E; Prantzos, N; Raffelt, G; Reimer, O; Rhode, W; Ryde, F; Schmidt, C; Silk, J; Shustov, B M; Strong, A; Tanvir, N; Thielemann, F -K; Tibolla, O; Tierney, D; Trümper, J; Varshalovich, D A; Wilms, J; Wrochna, G; Zdziarski, A; Zoglauer, A

    2011-01-01

    We propose to perform a continuously scanning all-sky survey from 200 keV to 80 MeV achieving a sensitivity which is better by a factor of 40 or more compared to the previous missions in this energy range. The Gamma-Ray Imaging, Polarimetry and Spectroscopy (GRIPS) mission addresses fundamental questions in ESA's Cosmic Vision plan. Among the major themes of the strategic plan, GRIPS has its focus on the evolving, violent Universe, exploring a unique energy window. We propose to investigate $\\gamma$-ray bursts and blazars, the mechanisms behind supernova explosions, nucleosynthesis and spallation, the enigmatic origin of positrons in our Galaxy, and the nature of radiation processes and particle acceleration in extreme cosmic sources including pulsars and magnetars. The natural energy scale for these non-thermal processes is of the order of MeV. Although they can be partially and indirectly studied using other methods, only the proposed GRIPS measurements will provide direct access to their primary photons. G...

  4. Channeling of ultra-relativistic positrons in bent diamond crystals

    Directory of Open Access Journals (Sweden)

    R.G. Polozkov

    2015-06-01

    Full Text Available Results of numerical simulations of channeling of ultra-relativistic positrons are reported for straight and uniformly bent diamond crystals. The projectile trajectories in a crystal are computed using a newly developed module of the MBN Explorer package which simulates classical trajectories in a crystalline medium by integrating the relativistic equations of motion with account for the interaction between the projectile and the crystal atoms. The Monte Carlo method is employed to sample the incoming positrons and to account for thermal vibrations of the crystal atoms. The channeling parameters and emission spectra of incident positrons with a projecti le energy of 855 MeV along C(110 crystallographic planes are calculated for different bending radii of the crystal. Two features of the emission spectrum associated with positron oscillations in a channel and synchrotron radiation are studied as a function of crystal curvature.

  5. Simulation of a Laue lens with bent Ge(111) crystals

    CERN Document Server

    Valsan, Vineeth; Frontera, Filippo; Liccardo, Vincenzo; Caroli, Ezio; Stephen, John B

    2015-01-01

    In the context of Laue project for focusing hard X-/ soft gamma-rays, an entire Laue lens, using bent Ge(111) crystal tiles, with 40 meters curvature radius, is simulated with a focal length of 20 meters. The focusing energy band is between 80 keV and 600 keV. The distortion of the output image of the lens on the focal plane due to the effect of crystal tile misalignment as well as the radial distortion arising from the curvature of the crystal is discussed in detail. Expected detection efficiency and instrument background is also estimated. Finally the sensitivity of the Laue lens is calculated. A quantitative analysis of the results of these simulation is also presented.

  6. Gamma-ray streaming in bent ducts and voids

    Energy Technology Data Exchange (ETDEWEB)

    Bourdet, L.; Nimal, J.C.; Vergnaud, T.

    1983-05-01

    We have developed an analytical method to calculate gamma-ray streaming through straight ducts and a numerical method to study the gamma propagation in bends or in annular clearances. The whole set allows a rigorous treatment of gamma streaming through bent ducts. In the same time a Monte Carlo method allows to study any form of geometry, by using sophisticated biasing techniques. All these developments are made with a simplified albedo. An easy to use code is also proposed to calculate very general albedos and a code to calculate the dose rate due to reflection in a room. Gamma dose rate albedos are determined for all elements and the energy range which concerns fission reactors.

  7. Levelized Cost of Energy for a Backward Bent Duct Buoy

    Energy Technology Data Exchange (ETDEWEB)

    Bull, Diana; Jenne, D. Scott; Smith, Christopher S.; Copping, Andrea E.; Copeland, Guild

    2016-12-01

    The Reference Model Project, supported by the U.S. Department of Energy, was developed to provide publically available technical and economic benchmarks for a variety of marine energy converters. The methodology to achieve these benchmarks is to develop public domain designs that incorporate power performance estimates, structural models, anchor and mooring designs, power conversion chain designs, and estimates of the operations and maintenance, installation, and environmental permitting required. The reference model designs are intended to be conservative, robust, and experimentally verified. The Backward Bent Duct Buoy (BBDB) presented in this paper is one of three wave energy conversion devices studied within the Reference Model Project. Comprehensive modeling of the BBDB in a Northern California climate has enabled a full levelized cost of energy (LCOE) analysis to be completed on this device.

  8. Bent Fiber Sensor for Preservative Detection in Milk

    Directory of Open Access Journals (Sweden)

    Omer Galip Saracoglu

    2016-12-01

    Full Text Available A fiber optic sensor sensitive to refractive index changes of the outer region of the fiber cladding is presented. The sensor uses bent plastic optical fibers in different bending lengths to increase sensitivity. Measurements were made for low-fat milk, the refractive index of which is altered by some preservatives such as formaldehyde, hydrogen peroxide, and sodium carbonate. Concentrations of the preservatives in the milk were changed between 0% and 14.3% while the refractive indices occurred between 1.34550 and 1.35093 for the minimum (0% and maximum (14.286% concentrations of sodium carbonate, respectively. Due to bending-induced sensitivity, the sensor is able to detect refractive index changes less of than 0.4%. The results show that there is excellent linearity between the concentration and normalized response of the sensor.

  9. Double twist helical nanofilaments in bent-core liquid crystals

    Science.gov (United States)

    Zhang, Cuiyu; Diorio, Nicholas; Lavrentovich, Oleg D.; Jakli, Antal

    2014-03-01

    Cryo-TEM observations on 40-150 nm films of four bent-core liquid crystal materials in their helical nanofilament (HNF) phase show that the filaments get deformed near the substrate, and the subsequent arrays of nanofilaments are not parallel, but twisted with respect to each other. The effect can explain the mysterious properties of the HNF materials, such as structural color and ambidextrous optical activity. The observed double twist structure was not expected in the previous models of this phase. Being principally different from the packing of molecules in the twist grain boundary (TGB) and blue (BP) phases, the double-twist structure of HNF expands the rich word of nanostructured organic materials. This work was financially supported by NSF DMR-0964765 and DMR 1104850. The cryo-TEM facility was supported by the Ohio Research Scholars Program. We are grateful for Prof. G. Heppke and Dr. D. Lotsch for providing the PnOPIMB materials for us.

  10. Handgrip Strength and Factors Associated in Poor Elderly Assisted at a Primary Care Unit in Rio de Janeiro, Brazil

    Science.gov (United States)

    Lino, Valéria Teresa Saraiva; Rodrigues, Nádia Cristina Pinheiro; O’Dwyer, Gisele; Andrade, Mônica Kramer de Noronha; Mattos, Inês Echenique; Portela, Margareth Crisóstomo

    2016-01-01

    Introduction Sarcopenia is a condition diagnosed when the patient presents low muscle mass, plus low muscle strength or low physical performance. Muscle weakness in the oldest (dynapenia) is a major public health concern because it predicts future all-cause mortality and is associated with falls, disability, cardiovascular mortality and morbidity. Grip strength is a simple method for assessment of muscle function in clinical practice. Objective To estimate the grip strength and identify factors associated with handgrip strength variation in elderly people with low socioeconomic status. Methods Cross-sectional study based on a multidimensional assessment of primary care users that were 60 years or older. The sample size was calculated using an estimated prevalence of depression in older adults of 20%. A kappa coefficient of 0.6 with a 95% confidence interval was used to generate a conservative sample size of 180 individuals. Procedures: tests and scales to assess humor, cognition (MMSE), basic (ADL) and instrumental activities (IADL) of daily living, mobility (Timed Up and Go), strength, height, Body Mass Index (BMI) and social support were applied. Questions about falls, chronic diseases and self-rated health (SRH) were also included. Statistical Analysis: Mean, standard deviation and statistical tests were used to compare grip strength means by demographic and health factors. A multivariate linear model was used to explain the relationship of the predictors with grip strength. Results The group was composed predominantly by women (73%) with a very low level of education (mean 3 years of schooling), mean age of 73.09 (± 7.05) years old, good mobility and without IADL impairment. Mean grip strength of male and female were 31.86Kg (SD 5.55) and 21.69Kg (SD 4.48) [p- 0.0001], respectively. Low grip strength was present in 27.7% of women and 39.6% of men. As expected, men and younger participants had higher grip strength than women and older individuals. In the

  11. Muscle Strength, Physical Activity, and Functional Limitations in Older Adults with Central Obesity

    Directory of Open Access Journals (Sweden)

    Cassandra M. Germain

    2016-01-01

    Full Text Available Background. Obesity and muscle weakness are independently associated with increased risk of physical and functional impairment in older adults. It is unknown whether physical activity (PA and muscle strength combined provide added protection against functional impairment. This study examines the association between muscle strength, PA, and functional outcomes in older adults with central obesity. Methods. Prevalence and odds of physical (PL, ADL, and IADL limitation were calculated for 6,388 community dwelling adults aged ≥ 60 with central obesity. Individuals were stratified by sex-specific hand grip tertiles and PA. Logistic models were adjusted for age, education, comorbidities, and body-mass index and weighted. Results. Overall prevalence of PL and ADL and IADL limitations were progressively lower by grip category. Within grip categories, prevalence was lower for individuals who were active than those who were inactive. Adjusted models showed significantly lower odds of PL OR 0.42 [0.31, 0.56]; ADL OR 0.60 [0.43, 0.84], and IADL OR 0.46 [0.35, 0.61] for those in the highest grip strength category as compared to those in the lowest grip category. Conclusion. Improving grip strength in obese elders who are not able to engage in traditional exercise is important for reducing odds of physical and functional impairment.

  12. Effect of object width on precision grip force and finger posture.

    Science.gov (United States)

    Domalain, M; Vigouroux, L; Danion, F; Sevrez, V; Berton, E

    2008-09-01

    This study aimed to define the effect of object width on spontaneous grasp. Participants held objects of various masses (0.75 to 2.25 kg) and widths (3.5 to 9.5 cm) between thumb and index finger. Grip force, maximal grip force and corresponding finger postures were recorded using an embedded force sensor and an optoelectronic system, respectively. Results showed that index finger joints varied to accommodate the object width, whereas thumb posture remained constant across conditions. For a given object mass, grip force increased as a function of object width, although this result is not dictated by the laws of mechanics. Because maximal grip force also increased with object width, we hypothesise that participants maintain a constant ratio between grip force and their maximal grip force at each given width. Altogether we conclude that when the task consists in manipulating objects/tools, the optimal width is different than when maximal force exertions are required.

  13. Discrimination of handlebar grip samples by fourier transform infrared microspectroscopy analysis and statistics

    Directory of Open Access Journals (Sweden)

    Zeyu Lin

    2017-01-01

    Full Text Available In this paper, the authors presented a study on the discrimination of handlebar grip samples, to provide effective forensic science service for hit and run traffic cases. 50 bicycle handlebar grip samples, 49 electric bike handlebar grip samples, and 96 motorcycle handlebar grip samples have been randomly collected by the local police in Beijing (China. Fourier transform infrared microspectroscopy (FTIR was utilized as analytical technology. Then, target absorption selection, data pretreatment, and discrimination of linked samples and unlinked samples were chosen as three steps to improve the discrimination of FTIR spectrums collected from different handlebar grip samples. Principal component analysis and receiver operating characteristic curve were utilized to evaluate different data selection methods and different data pretreatment methods, respectively. It is possible to explore the evidential value of handlebar grip residue evidence through instrumental analysis and statistical treatments. It will provide a universal discrimination method for other forensic science samples as well.

  14. Reversible greyscale memory effect of a bent-core liquid crystal

    Energy Technology Data Exchange (ETDEWEB)

    Hong Zhe; Jin Yan [Department of Display Engineering, Hoseo University, Asan, Chungnam 336-795 (Korea, Republic of); Lee, Ji-Hoon; Yoon, Tae-Hoon [School of Electrical Engineering, Pusan National University, Busan 609-735 (Korea, Republic of); Choi, E-Joon; Lee, Eun-Woo, E-mail: jihoonlee@pusan.ac.kr, E-mail: ejchoi@kumoh.ac.kr [Department of Polymer Science and Engineering, Kumoh National Institute of Technology, Gumi, Gyungbuk 730-701 (Korea, Republic of)

    2011-10-19

    Memory effect of a bent-core liquid crystal (LC) in smectic A phase was studied. The bent-core LC formed spatially distributed domains with different threshold fields, and the domains showed a bistable switching from a planar to a homeotropic state under an electric field across the cell. The fraction of homeotropic domains was gradually increased with stronger electric field, thus an analogue greyscale memory effect was obtained by the relative fraction between the planar and homeotropic domains. The bent-core molecules could be reversibly switched back to the initial planar state by applying an in-plane electric field.

  15. Dynamical focusing by bent, asymmetrically cut perfect crystals in Laue geometry.

    Science.gov (United States)

    Guigay, J P; Ferrero, C

    2016-07-01

    A semi-analytical approach based on the influence functions of a point source located on the crystal surface has been adopted to show that the focusing ability of cylindrically bent Laue crystals may be strongly enhanced by replacing symmetrically cut crystals with asymmetrically cut crystals. This approach is generally applicable to any distance between the X-ray source and the focusing bent crystal. A mathematically straightforward method to simplify the derivation of the already known expression of the influence functions in the case of deformed crystals with a constant strain gradient (e.g. cylindrically bent crystals) is also presented.

  16. ANALYTICAL RESEARCH ON THE GRIP VARIATION OF TWO-AXLE CAR

    Directory of Open Access Journals (Sweden)

    Rosen IVANOV

    2016-12-01

    Full Text Available This paper presents a theoretical investigation on the decrease in grip coefficient of a car due to the car mass changes for three different running conditions- straightforward, motion in curve and braking. The grip of two types of cars - with forward and rear traction, equipped with three models of tires are studied. The results show a significant decrease of the grip coefficient in longitudinal and lateral directions.

  17. Control of Precision Grip Force in Lifting and Holding of Low-Mass Objects.

    Directory of Open Access Journals (Sweden)

    Yuichi Hiramatsu

    Full Text Available Few studies have investigated the control of grip force when manipulating an object with an extremely small mass using a precision grip, although some related information has been provided by studies conducted in an unusual microgravity environment. Grip-load force coordination was examined while healthy adults (N = 17 held a moveable instrumented apparatus with its mass changed between 6 g and 200 g in 14 steps, with its grip surface set as either sandpaper or rayon. Additional measurements of grip-force-dependent finger-surface contact area and finger skin indentation, as well as a test of weight discrimination, were also performed. For each surface condition, the static grip force was modulated in parallel with load force while holding the object of a mass above 30 g. For objects with mass smaller than 30 g, on the other hand, the parallel relationship was changed, resulting in a progressive increase in grip-to-load force (GF/LF ratio. The rayon had a higher GF/LF force ratio across all mass levels. The proportion of safety margin in the static grip force and normalized moment-to-moment variability of the static grip force were also elevated towards the lower end of the object mass for both surfaces. These findings indicate that the strategy of grip force control for holding objects with an extremely small mass differs from that with a mass above 30 g. The data for the contact area, skin indentation, and weight discrimination suggest that a decreased level of cutaneous feedback signals from the finger pads could have played some role in a cost function in efficient grip force control with low-mass objects. The elevated grip force variability associated with signal-dependent and internal noises, and anticipated inertial force on the held object due to acceleration of the arm and hand, could also have contributed to the cost function.

  18. Finger pad friction and its role in grip and touch

    Science.gov (United States)

    Adams, Michael J.; Johnson, Simon A.; Lefèvre, Philippe; Lévesque, Vincent; Hayward, Vincent; André, Thibaut; Thonnard, Jean-Louis

    2013-01-01

    Many aspects of both grip function and tactile perception depend on complex frictional interactions occurring in the contact zone of the finger pad, which is the subject of the current review. While it is well established that friction plays a crucial role in grip function, its exact contribution for discriminatory touch involving the sliding of a finger pad is more elusive. For texture discrimination, it is clear that vibrotaction plays an important role in the discriminatory mechanisms. Among other factors, friction impacts the nature of the vibrations generated by the relative movement of the fingertip skin against a probed object. Friction also has a major influence on the perceived tactile pleasantness of a surface. The contact mechanics of a finger pad is governed by the fingerprint ridges and the sweat that is exuded from pores located on these ridges. Counterintuitively, the coefficient of friction can increase by an order of magnitude in a period of tens of seconds when in contact with an impermeably smooth surface, such as glass. In contrast, the value will decrease for a porous surface, such as paper. The increase in friction is attributed to an occlusion mechanism and can be described by first-order kinetics. Surprisingly, the sensitivity of the coefficient of friction to the normal load and sliding velocity is comparatively of second order, yet these dependencies provide the main basis of theoretical models which, to-date, largely ignore the time evolution of the frictional dynamics. One well-known effect on taction is the possibility of inducing stick–slip if the friction decreases with increasing sliding velocity. Moreover, the initial slip of a finger pad occurs by the propagation of an annulus of failure from the perimeter of the contact zone and this phenomenon could be important in tactile perception and grip function. PMID:23256185

  19. GRIPS - Gamma-Ray Burst Investigation via Polarimetry and Spectroscopy

    CERN Document Server

    Greiner, J

    2008-01-01

    The primary scientific goal of the GRIPS mission is to revolutionize our understanding of the early universe using gamma-ray bursts. We propose a new generation gamma-ray observatory capable of unprecedented spectroscopy over a wide range of gamma-ray energies (200 keV--50 MeV) and of polarimetry (200--1000 keV). Secondary goals achievable by this mission include direct measurements of supernova interiors through gamma-rays from radioactive decays, nuclear astrophysics with massive stars and novae, and studies of particle acceleration near compact stars, interstellar shocks, and clusters of galaxies.

  20. GRIP Database original data - GRIPDB | LSDB Archive [Life Science Database Archive metadata

    Lifescience Database Archive (English)

    Full Text Available List Contact us GRIPDB GRIP Database original data Data detail Data name GRIP Database original data DOI 10....18908/lsdba.nbdc01665-006 Description of data contents GRIP Database original data It consists of data table...s and sequences. Data file File name: gripdb_original_data.zip File URL: ftp://ftp.biosciencedbc.jp/archive/gripdb/LATEST/gripdb_orig...e Database Description Download License Update History of This Database Site Policy | Contact Us GRIP Database original data - GRIPDB | LSDB Archive ... ...inal_data.zip File size: 779 KB Simple search URL - Data

  1. Pencil grips, legibility, and speed of fourth-graders' writing in cursive.

    Science.gov (United States)

    Koziatek, Susan M; Powell, Nancy J

    2003-01-01

    The purpose of this research was to study how the speed and legibility of fourth-graders handwriting was affected by type of pencil grip on the Evaluation Tool of Children's Handwriting-Cursive. Ninety-five typically developing students and 6 students receiving special education services completed the Evaluation Tool of Children's Handwriting-Cursive (ETCH-C). Photographs were taken of their pencil grips while they wrote the alphabet. One-way ANOVAs were calculated to compare legibility rates and writing speeds by type of pencil grip. Ninety-nine of the students used one of four pencil grips including the dynamic tripod (38 students), the dynamic quadrupod (18), the lateral tripod (22), and the lateral quadrupod (21). One student used the four-finger pencil grip and one used the interdigital pencil grip. Mean cursive writing speeds were similar for all pencil grips except for the interdigital grasp. Speeds obtained were slower than recently published fourth-grade speeds ranging from a mean of 29.45 to 34.75 letters per minute. CONCLUSION. This study found the lateral quadrupod and four-finger pencil grips to be as functional as the dynamic tripod, lateral tripod, and dynamic quadrupod pencil grips. This study provides average handwriting speeds for fourth-grade students on the ETCH-C.

  2. Delayed grip relaxation and altered modulation of intracortical inhibition with aging

    Science.gov (United States)

    Motawar, Binal; Stinear, James W.; Lauer, Abigail W.; Ramakrishnan, V. Viswanathan; Seo, Na Jin

    2015-01-01

    Grip relaxation is a voluntary action that requires an increase in short-interval intracortical inhibition (SICI) in healthy young adults, rather than a simple termination of excitatory drive. The way aging affects this voluntary inhibitory action and timing of grip relaxation is currently unknown. The objective of this study was to examine aging-related delays in grip relaxation and SICI modulation for the flexor digitorum superficialis (FDS) muscle during grip relaxation. The main finding was that young adults increased SICI to relax their grips, whereas older adults did not increase SICI with a prolonged grip relaxation time (prelaxation time). A secondary experiment showed that both young and older adults did not change H reflex excitability during grip relaxation. Our data suggest that grip relaxation is mediated by increased cortical inhibitory output in young adults, and aging-related impairment in increasing cortical inhibitory output may hamper timely cessation of muscle activity. Our data also suggest a lesser role of the spinal circuits in grip muscle relaxation. This knowledge may contribute to understanding of aging-related movement deterioration and development of interventions for improving modulation of SICI to improve muscle relaxation and movement coordination. PMID:26686531

  3. Elliptically Bent X-ray Mirrors with Active Temperature Stabilization

    Energy Technology Data Exchange (ETDEWEB)

    Yuan, Sheng; Church, Matthew; Yashchuk, Valeriy V.; Goldberg, Kenneth A.; Celestre, Rich; McKinney, Wayne R.; Kirschman, Jonathan; Morrison, Greg; Noll, Tino; Warwick, Tony; Padmore, Howard A.

    2010-01-31

    We present details of design of elliptically bent Kirkpatrick-Baez mirrors developed and successfully used at the Advanced Light Source for submicron focusing. A distinctive feature of the mirror design is an active temperature stabilization based on a Peltier element attached directly to the mirror body. The design and materials have been carefully optimized to provide high heat conductance between the mirror body and substrate. We describe the experimental procedures used when assembling and precisely shaping the mirrors, with special attention paid to laboratory testing of the mirror-temperature stabilization. For this purpose, the temperature dependence of the surface slope profile of a specially fabricated test mirror placed inside a temperature-controlled container was measured. We demonstrate that with active mirror-temperature stabilization, a change of the surrounding temperature by more than 3K does not noticeably affect the mirror figure. Without temperature stabilization, the surface slope changes by approximately 1.5 ?mu rad rms (primarily defocus) under the same conditions.

  4. Analytic Matrix Method for the Study of Propagation Characteristics of a Bent Planar Waveguide

    Institute of Scientific and Technical Information of China (English)

    LIU Qing; CAO Zhuang-Qi; SHEN Qi-Shun; DOU Xiao-Ming; CHEN Ying-Li

    2000-01-01

    An analytic matrix method is used to analyze and accurately calculate the propagation constant and bendinglosses of a bent planar waveguide. This method gives not only a dispersion equation with explicit physical insight,but also accurate complex propagation constants.

  5. Grip pressure measurements during activities of daily life

    Science.gov (United States)

    Sanford, Joe; Young, Carolyn; Popa, Dan; Bugnariu, Nicoleta; Patterson, Rita

    2014-06-01

    Research has expanded human-machine communication methods past direct programming and standard hand- held joystick control. Individual force sensors have been used as a simple means of providing environmental information to a robot and research has shown that more advanced sensitive skins can be viable input devices. These touch sensitive surfaces allow for additional modes of interaction between machines in open, undefined environments. These interactions include object detection for navigation and safety but can also be used for recognition of users command gestures by their machine partner. Key to successful implementation of these gestures is the understanding of varied strategies used for communication and interaction and the development of performance limits. Data of dominant hand grip forces was collected using a Tekscan Grip VersaTek Pressure Measurement System during opening of a door. Analysis of data from 10 male and female subjects is presented. The results of qualitative and quantitative analysis of these data show variability in hand configurations between users. Average data over the cohort is reported. These data will be used in future work to provide human metrology constraints and limits for use in simulation and design of new, physical human-robot interaction systems.

  6. Oblique detonation waves stabilized in rectangular-cross-section bent tubes

    OpenAIRE

    2011-01-01

    Oblique detonation waves, which are generated by a fundamental detonation phenomenon occurring in bent tubes, may be applied to fuel combustion in high-efficiency engines such as a pulse detonation engine (PDE) and a rotating detonation engine (RDE). The present study has experimentally demonstrated that steady-state oblique detonation waves propagated stably through rectangular-cross-section bent tubes by visualizing these waves using a high-speed camera and the shadowgraph method. The obliq...

  7. On the energy dependence of proton beam extraction with a bent crystal

    CERN Document Server

    Arduini, Gianluigi; Fidecaro, Giuseppe; Gyr, Marcel; Herr, Werner; Klem, J T; Mikkelsen, U; Weisse, E

    1998-01-01

    Proton beam extraction from the CERN SPS by means of a bent silicon crystal is reported at three different energies, 14 GeV, 120 GeV and 270 GeV. The experimental results are compared to computer simulations which contain a sound model of the SPS accelerator as well as the channeling phenomena in bent crystals. The overall energy dependence of crystal assisted proton beam extraction is understood and provides the basis to discuss such a scheme for future accelerators.

  8. The Relationship of Isometric Grip Strength, Optimal Dynamometer Settings, and Certain Anthropometric Factors

    Science.gov (United States)

    1990-05-01

    of the long flexors of the digits ( Kapandji , 1982). This may be the result of losing the fulcrum that is normally provided as the tendons pass over an...univariate and multivariate examination of measurement error in anthropometry. American Journal of Physical Anthropology, 40, 197-203. Kapandji , I. A. (1982

  9. Infants' Grip Strength Predicts Mu Rhythm Attenuation during Observation of Lifting Actions with Weighted Blocks

    Science.gov (United States)

    Upshaw, Michaela B.; Bernier, Raphael A.; Sommerville, Jessica A.

    2016-01-01

    Research has established that the body is fundamentally involved in perception: bodily experience influences activation of the shared neural system underlying action perception and production during action observation, and bodily characteristics influence perception of the spatial environment. However, whether bodily characteristics influence…

  10. Cross-national differences in grip strength among 50+ year old Europeans

    DEFF Research Database (Denmark)

    Andersen-Ranberg, Karen; Petersen, Inge; Frederiksen, Henrik;

    2009-01-01

    , education, health and socioeconomic status. The relative excess was found to be 11% and the absolute difference 5.0 kg for 50- to 54-year-old men, increasing to 28% and 6.9 kg among 80+ year-old men. The corresponding figures for women were 16% and 4.3 kg, and 21% and 3.5 kg, respectively. Southern European...... with higher rates of functional decline and mortality, and thus may be used as a health indicator, it is of interest to examine whether the results on extremely old can be reproduced in a large-scale European survey. GS was measured in a cross-sectional population-based sample of 27,456 individuals aged 50...

  11. Grip strength of severely malnourished children during nutritional rehabilitation in the Jimma hospital of Ethiopia

    OpenAIRE

    Fonguh, Sylvanus

    2011-01-01

    The frequent occurence of missing data in scientific studies is not uncommon. In longitudinal clinical studies for instance, one would expect, in a 'dream land' scenario, a complete profile for each study subject. Unfortunately, this is rarely the case. Plagued therefore with the issue of missingness, it becomes vital to understand the mechanism that led to the missing data to be able to perform analyses that will lead to valid inference. Under the missing at random (MAR) assumption, likeli...

  12. A new class of hyper-bent Boolean functions in binomial forms

    CERN Document Server

    Wang, Baocheng; Qi, Yanfeng; Yang, Yixian; Xu, Maozhi

    2011-01-01

    Bent functions, which are maximally nonlinear Boolean functions with even numbers of variables and whose Hamming distance to the set of all affine functions equals $2^{n-1}\\pm 2^{\\frac{n}{2}-1}$, were introduced by Rothaus in 1976 when he considered problems in combinatorics. Bent functions have been extensively studied due to their applications in cryptography, such as S-box, block cipher and stream cipher. Further, they have been applied to coding theory, spread spectrum and combinatorial design. Hyper-bent functions, as a special class of bent functions, were introduced by Youssef and Gong in 2001, which have stronger properties and rarer elements. Many research focus on the construction of bent and hyper-bent functions. In this paper, we consider functions defined over $\\mathbb{F}_{2^n}$ by $f_{a,b}:=\\mathrm{Tr}_{1}^{n}(ax^{(2^m-1)})+\\mathrm{Tr}_{1}^{4}(bx^{\\frac{2^n-1}{5}})$, where $n=2m$, $m\\equiv 2\\pmod 4$, $a\\in \\mathbb{F}_{2^m}$ and $b\\in\\mathbb{F}_{16}$. When $a\\in \\mathbb{F}_{2^m}$ and $(b+1)(b^4+b...

  13. Optimal Scoring Methods of Hand-Strength Tests in Patients with Stroke

    Science.gov (United States)

    Huang, Sheau-Ling; Hsieh, Ching-Lin; Lin, Jau-Hong; Chen, Hui-Mei

    2011-01-01

    The purpose of this study was to determine the optimal scoring methods for measuring strength of the more-affected hand in patients with stroke by examining the effect of reducing measurement errors. Three hand-strength tests of grip, palmar pinch, and lateral pinch were administered at two sessions in 56 patients with stroke. Five scoring methods…

  14. Effects of Different Environment Temperatures on Some Motor Characteristics and Muscle Strength

    Science.gov (United States)

    Çakir, Ergün; Yüksek, Selami; Asma, Bülent; Arslanoglu, Erkal

    2016-01-01

    The aim of this study was determine the effects of different environment temperatures on motor characteristics and muscle strength. 15 athletes participated to study. Flexibility, vertical jump, hand grip-leg strength, 30m sprint, 20-meter shuttle run and coordination-agility tests were measured in five different environment temperatures. (22°C,…

  15. Biomimetics approach for methods to release microobjects from the gripping tool

    DEFF Research Database (Denmark)

    Gegeckaite, Asta; Moon, Jack; Hansen, Hans Nørgaard

    2005-01-01

    In the micro scale, gripping devices are working in the different way. New forces, working in the micro scale, like van der Waals, surface tension and electrostatics are influencing the gripping process. Handling of micro or even nano sized objects can be easily in the nature. Different types of ...

  16. Getting a Grip on Numbers: Numerical Magnitude Priming in Object Grasping

    Science.gov (United States)

    Lindemann, Oliver; Abolafia, Juan M.; Girardi, Giovanna; Bekkering, Harold

    2007-01-01

    To investigate the functional connection between numerical cognition and action planning, the authors required participants to perform different grasping responses depending on the parity status of Arabic digits. The results show that precision grip actions were initiated faster in response to small numbers, whereas power grips were initiated…

  17. 16 CFR Figure 5 to Part 1512 - Typical Handbrake Actuator Showing Grip Dimension

    Science.gov (United States)

    2010-01-01

    ... 16 Commercial Practices 2 2010-01-01 2010-01-01 false Typical Handbrake Actuator Showing Grip Dimension 5 Figure 5 to Part 1512 Commercial Practices CONSUMER PRODUCT SAFETY COMMISSION FEDERAL HAZARDOUS... Actuator Showing Grip Dimension EC03OC91.072 ...

  18. Biomimetics approach for methods to release microobjects from the gripping tool

    DEFF Research Database (Denmark)

    Gegeckaite, Asta; Moon, Jack; Hansen, Hans Nørgaard

    2005-01-01

    In the micro scale, gripping devices are working in the different way. New forces, working in the micro scale, like van der Waals, surface tension and electrostatics are influencing the gripping process. Handling of micro or even nano sized objects can be easily in the nature. Different types of ...

  19. Sex, race and age differences in muscle strength and limitations in community dwelling older adults: Data from the Health and Retirement Survey (HRS).

    Science.gov (United States)

    Germain, Cassandra M; Vasquez, Elizabeth; Batsis, John A; McQuoid, Douglas R

    2016-01-01

    Aging-related muscle weakness is associated with increased risk of functional limitations and disability. This study examined the association between varying degrees of hand grip strength on functional ability in community-dwelling older adults. Cross-sectional analysis of 4289 men and 5860 women ≥60 from 2006 and 2008 waves of the population-based Health and Retirement Study (HRS) were stratified by sex-specific grip strength tertiles (low, mid, high). Prevalence and adjusted odds of physical limitations (PL), and ADL/IADL limitation were calculated by sex, race/ethnicity and age group (60-69, 70-79, 80+). Models were weighted, adjusted for age, sex, race/ethnicity, education, smoking status, BMI, comorbidities and participation in physical activity. Prevalence of PL, ADL and IADL limitations were significantly lower among adults in the highest grip category as compared to those in the lowest grip category. Adjusted odds for PL OR 0.41[0.33,0.52]; ADL OR.51 [0.39,0.67], and IADL OR 0.47 [0.38-0.59] limitations were significantly lower among adults in the highest grip compared to the lowest grip category. However, notable differences were observed in the strength of these associations by gender, race and age group. Demographic characteristics are important factors to consider for risk stratification and the development of effective grip strength training interventions for older adults. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  20. Handgrip and general muscular strength and endurance during prolonged bedrest with isometric and isotonic leg exercise training

    Science.gov (United States)

    Greenleaf, J. E.; Starr, J. C.; Van Beaumont, W.; Convertino, V. A.

    1983-01-01

    Measurements of maximal grip strength and endurance at 40 percent max strength were obtained for 7 men 19-21 years of age, 1-2 days before and on the first recovery day during three 2-week bedrest (BR) periods, each separated by a 3-week ambulatory recovery period. The subjects performed isometric exercise (IME) for 1 hr/day, isotonic exercise (ITE) for 1 hr/day, and no exercise (NOE) in the three BR periods. It was found that the mean maximal grip strength was unchanged after all three BR periods. Mean grip endurance was found to be unchanged after IME and ITE training, but was significantly reduced after NOE. These results indicate that IME and ITE training during BR do not increase or decrease maximal grip strength, alghough they prevent loss of grip endurance, while the maximal strength of all other major muscle groups decreases in proportion to the length of BR to 70 days. The maximal strength reduction of the large muscle groups was found to be about twice that of the small muscle groups during BR. In addition, it is shown that changes in maximal strength after spaceflight, BR, or water immersion deconditioning cannot be predicted from changes in submaximal or maximal oxygen uptake values.

  1. Magnetic cloud models with bent and oblate cross-section boundaries

    Science.gov (United States)

    Démoulin, P.; Dasso, S.

    2009-11-01

    Context: Magnetic clouds (MCs) are formed by magnetic flux ropes that are ejected from the Sun as coronal mass ejections. These structures generally have low plasma beta and travel through the interplanetary medium interacting with the surrounding solar wind. Thus, the dynamical evolution of the internal magnetic structure of a MC is a consequence of both the conditions of its environment and of its own dynamical laws, which are mainly dominated by magnetic forces. Aims: With in-situ observations the magnetic field is only measured along the trajectory of the spacecraft across the MC. Therefore, a magnetic model is needed to reconstruct the magnetic configuration of the encountered MC. The main aim of the present work is to extend the widely used cylindrical model to arbitrary cross-section shapes. Methods: The flux rope boundary is parametrized to account for a broad range of shapes. Then, the internal structure of the flux rope is computed by expressing the magnetic field as a series of modes of a linear force-free field. Results: We analyze the magnetic field profile along straight cuts through the flux rope, in order to simulate the spacecraft crossing through a MC. We find that the magnetic field orientation is only weakly affected by the shape of the MC boundary. Therefore, the MC axis can approximately be found by the typical methods previously used (e.g., minimum variance). The boundary shape affects the magnetic field strength most. The measurement of how much the field strength peaks along the crossing provides an estimation of the aspect ratio of the flux-rope cross-section. The asymmetry of the field strength between the front and the back of the MC, after correcting for the time evolution (i.e., its aging during the observation of the MC), provides an estimation of the cross-section global bending. A flat or/and bent cross-section requires a large anisotropy of the total pressure imposed at the MC boundary by the surrounding medium. Conclusions: The

  2. Force analysis of the rowing stroke employing two differing oar grips.

    Science.gov (United States)

    Bompa, T O; Hebbelinck, M; Van Gheluwe, B

    1985-06-01

    The velocity of the rowing boat appears to depend on the force which the athlete applies at the handle of the oar. Although force is generated by legs, upper body, and arms, the latter are the only limbs which actually transmit and apply the force against the oar. The force output of the arms seem to be a function of the forearm position used by the athlete while gripping the oar. The traditional gripping technique is with the forearms in pronation. This technique was never challenged or scientifically researched to see whatever a modified one might lead to better efficiency. Consequently, the purpose of this investigation was to analyze whether athletes' force output differed if the gripping technique was changed from pronation to a semiprone grip (one arm prone, the other semiprone). Under the specific conditions of this investigation it was demonstrated that the semiprone position was generating greater force output, thus being superior to the classical prone grip.

  3. Clinical and radiographic delineation of Bent Bone Dysplasia-FGFR2 type or Bent Bone Dysplasia with Distinctive Clavicles and Angel-shaped Phalanges.

    Science.gov (United States)

    Krakow, Deborah; Cohn, Daniel H; Wilcox, William R; Noh, Grace J; Raffel, Leslie J; Sarukhanov, Anna; Ivanova, Margarita H; Danielpour, Moise; Grange, Dorothy K; Elliott, Alison M; Bernstein, Jonathan A; Rimoin, David L; Merrill, Amy E; Lachman, Ralph S

    2016-10-01

    Bent Bone Dysplasia-FGFR2 type is a relatively recently described bent bone phenotype with diagnostic clinical, radiographic, and molecular characteristics. Here we report on 11 individuals, including the original four patients plus seven new individuals with three longer-term survivors. The prenatal phenotype included stillbirth, bending of the femora, and a high incidence of polyhydramnios, prematurity, and perinatal death in three of 11 patients in the series. The survivors presented with characteristic radiographic findings that were observed among those with lethality, including bent bones, distinctive (moustache-shaped) small clavicles, angel-shaped metacarpals and phalanges, poor mineralization of the calvarium, and craniosynostosis. Craniofacial abnormalities, hirsutism, hepatic abnormalities, and genitourinary abnormalities were noted as well. Longer-term survivors all needed ventilator support. Heterozygosity for mutations in the gene that encodes Fibroblast Growth Factor Receptor 2 (FGFR2) was identified in the nine individuals with available DNA. Description of these patients expands the prenatal and postnatal findings of Bent Bone Dysplasia-FGFR2 type and adds to the phenotypic spectrum among all FGFR2 disorders. © 2016 Wiley Periodicals, Inc.

  4. Muscle-Pair Specific Distribution and Grip-Type Modulation of Neural Common Input to Extrinsic Digit Flexors

    Science.gov (United States)

    Winges, Sara A.; Johnston, Jamie A.; Santello, Marco

    2007-01-01

    To gain insight into the synergistic control of hand muscles, we have recently quantified the strength of correlated neural activity across motor units from extrinsic digit flexors during a five-digit object-hold task. We found stronger synchrony and coherence across motor units from thumb and index finger flexor muscle compartment than between the thumb flexor and other finger flexor muscle compartments. The present study of two-digit object hold was designed to determine the extent to which such distribution of common input among thumb-finger flexor muscle compartments, revealed by holding an object with five digits, is preserved when varying the functional role of a given digit pair. We recorded normal force exerted by the digits and electrical activity of single motor units from muscle flexor pollicis longus (FPL) and two compartments of the m. flexor digitorum profundus (FDP2 and FDP3; index and middle finger, respectively). Consistent with our previous results from five-digit grasping, synchrony and coherence across motor units from FPL-FDP2 was significantly stronger than in FPL-FDP3 during object hold with two digits [common input strength: 0.49 ± 0.02 and 0.35 ± 0.02 (means ± SE), respectively; peak coherence: 0.0054 and 0.0038, respectively]. This suggests that the distribution of common neural input is muscle-pair specific regardless of grip type. However, the strength of coherence, but not synchrony, was significantly stronger in two- versus five-digit object hold for both muscle combinations, suggesting the periodicity of common input is sensitive to grip type. PMID:16723414

  5. Effects of carpal tunnel syndrome on dexterous manipulation are grip type-dependent.

    Science.gov (United States)

    Zhang, Wei; Johnston, Jamie A; Ross, Mark A; Sanniec, Kyle; Gleason, Elizabeth A; Dueck, Amylou C; Santello, Marco

    2013-01-01

    Carpal tunnel syndrome (CTS) impairs sensation of a subset of digits. Although the effects of CTS on manipulation performed with CTS-affected digits have been studied using precision grip tasks, the extent to which CTS affects multi-digit force coordination has only recently been studied. Whole-hand manipulation studies have shown that CTS patients retain the ability to modulate multi-digit forces to object mass, mass distribution, and texture. However, CTS results in sensorimotor deficits relative to healthy controls, including significantly larger grip force and lower ability to balance the torques generated by the digits. Here we investigated the effects of CTS on multi-digit force modulation to object weight when manipulating an object with a variable number of fingers. We hypothesized that CTS patients would be able to modulate digit forces to object weight. However, as different grip types involve the exclusive use of CTS-affected digits ('uniform' grips) or a combination of CTS-affected and non-affected digits ('mixed' grips), we addressed the question of whether 'mixed' grips would reduce or worsen CTS-induced force coordination deficits. The former scenario would be due to adding digits with intact tactile feedback, whereas the latter scenario might occur due to a potentially greater challenge for the central nervous system of integrating 'noisy' and intact tactile feedback. CTS patients learned multi-digit force modulation to object weight regardless of grip type. Although controls exerted the same total grip force across all grip types, patients exerted significantly larger grip force than controls but only for manipulations with four and five digits. Importantly, this effect was due to CTS patients' inability to change the finger force distribution when adding the ring and little fingers. These findings suggest that CTS primarily challenges sensorimotor integration processes for dexterous manipulation underlying the coordination of CTS-affected and non

  6. Effects of carpal tunnel syndrome on dexterous manipulation are grip type-dependent.

    Directory of Open Access Journals (Sweden)

    Wei Zhang

    Full Text Available Carpal tunnel syndrome (CTS impairs sensation of a subset of digits. Although the effects of CTS on manipulation performed with CTS-affected digits have been studied using precision grip tasks, the extent to which CTS affects multi-digit force coordination has only recently been studied. Whole-hand manipulation studies have shown that CTS patients retain the ability to modulate multi-digit forces to object mass, mass distribution, and texture. However, CTS results in sensorimotor deficits relative to healthy controls, including significantly larger grip force and lower ability to balance the torques generated by the digits. Here we investigated the effects of CTS on multi-digit force modulation to object weight when manipulating an object with a variable number of fingers. We hypothesized that CTS patients would be able to modulate digit forces to object weight. However, as different grip types involve the exclusive use of CTS-affected digits ('uniform' grips or a combination of CTS-affected and non-affected digits ('mixed' grips, we addressed the question of whether 'mixed' grips would reduce or worsen CTS-induced force coordination deficits. The former scenario would be due to adding digits with intact tactile feedback, whereas the latter scenario might occur due to a potentially greater challenge for the central nervous system of integrating 'noisy' and intact tactile feedback. CTS patients learned multi-digit force modulation to object weight regardless of grip type. Although controls exerted the same total grip force across all grip types, patients exerted significantly larger grip force than controls but only for manipulations with four and five digits. Importantly, this effect was due to CTS patients' inability to change the finger force distribution when adding the ring and little fingers. These findings suggest that CTS primarily challenges sensorimotor integration processes for dexterous manipulation underlying the coordination of CTS

  7. Two-dimensional refractive index and birefringence profiles of a graded index bent optical fibre

    Science.gov (United States)

    Ramadan, W. A.; Wahba, H. H.; Shams El-Din, M. A.

    2017-07-01

    A theory to recover refractive index profile of the bent graded index (GRIN) optical fibre, in core region, is proposed. This theory is applied to the bent GRIN optical fibre when it is located orthogonal in the light path of the object arm in digital holographic phase shifting interferometer; like Mach-Zehnder interferometer. In the experiment, the fibre is bent with two different bending radii and fixed on a microscope slide keeping it immersed in matching liquid. The produced phase shifted holograms, with the presence of the fibre, are recorded using an attached CCD camera. Two different processes controlling the index profile shape of the bent GRIN optical fibre are assumed. In the first process, a linear index variation is evolved from stresses in the direction of the bent radius. In the second one, there is a release of these stresses near the fibre surface, which depends on the fibre's radius. This will affect the outer free surface of the cladding. Based on these assumptions, we are able to construct the index profile in two dimensions normal to the optical axis. We propose two functions to describe the refractive index profiles in cladding and the core regions of the bent GRIN optical fibre. The recorded phase shifted holograms are combined, reconstructed and analyzed to get the phase map of the bent GRIN optical fibre. Comparing the extracted optical phase differences with the calculated ones, a good agreement between them is found. This means that the used two dimensional proposed functions, which are describing cladding and the core indices profiles, are the most proper in this situation. Thus, we are able to determine a realistic induced birefringence profile inside the fibre which is generated by a bending operation, not only in the cladding but also in graded index core region as well.

  8. Alteration in Peripheral Muscle Strength among Overweight and Obese Individuals: A Systematic Review

    Directory of Open Access Journals (Sweden)

    Vikram Mohan

    2017-04-01

    Full Text Available Peripheral muscle dysfunction in Overweight (OW and Obesity (OB leads to fatigue and activity limitations. However, there are contradictory views regarding the exact level with regard to hand grip and quadriceps muscle strength in OW and OB. The main objective of the present systematic review was to synthesize the literature for the strength part of the hand grip and quadriceps muscle strength among OW and OB. Literature search of Scopus, EBSCO and PubMed databases from 01.01.2004 to 30.06.2016, was performed. We set our search strategy using the terms “overweight OR obesity” AND “muscle strength” AND “grip OR quadriceps”. Two reviewers administered established eligible criteria and extracted the data. Strengthening the Reporting of Observational studies in Epidemiology (STROBE was used to assess the risk of bias. Sixteen articles which were included identified Handgrip Strength (HGS, shoulder flexor, elbow flexor and knee extensor were found to be altered. There were consistent results with an increase in quadriceps muscle strength, whereas differed results were found in hand grip to increase and decrease in muscle strength in the presence of OW and OB. It is concluded that HGS appeared to be diversified with findings of increased and decrease strength, whereas regarding the quadriceps muscles, the findings were homogeneous.

  9. Associations of Midlife to Late Life Fatigue With Physical Performance and Strength in Early Old Age

    DEFF Research Database (Denmark)

    Mänty, Minna Regina; Kuh, Diana; Cooper, Rachel

    2015-01-01

    objective measures: grip strength, standing balance, chair rising, and timed get-up-and-go (TUG) tests. RESULTS: There were associations between reports of frequent fatigue at both ages and poorer grip strength, chair rise, and TUG performance at 60 to 64 years. Furthermore, individuals reporting frequent...... fatigue at both ages had weaker grip strength (β = -4.09 kg, 95% confidence interval [CI] = -6.71 to -1.48) and slower chair rise (β = -4.65 repetitions/min, 95% CI = -6.65 to -2.64) and TUG (β = -4.22 cm/s, 95% CI = -12.16 to -2.28) speeds when compared with those who reported no fatigue at both time...

  10. Using Hand Grip Force as a Correlate of Longitudinal Acceleration Comfort for Rapid Transit Trains.

    Science.gov (United States)

    Guo, Beiyuan; Gan, Weide; Fang, Weining

    2015-07-02

    Longitudinal acceleration comfort is one of the essential metrics used to evaluate the ride comfort of train. The aim of this study was to investigate the effectiveness of using hand grip force as a correlate of longitudinal acceleration comfort of rapid transit trains. In the paper, a motion simulation system was set up and a two-stage experiment was designed to investigate the role of the grip force on the longitudinal comfort of rapid transit trains. The results of the experiment show that the incremental grip force was linearly correlated with the longitudinal acceleration value, while the incremental grip force had no correlation with the direction of the longitudinal acceleration vector. The results also show that the effects of incremental grip force and acceleration duration on the longitudinal comfort of rapid transit trains were significant. Based on multiple regression analysis, a step function model was established to predict the longitudinal comfort of rapid transit trains using the incremental grip force and the acceleration duration. The feasibility and practicably of the model was verified by a field test. Furthermore, a comparative analysis shows that the motion simulation system and the grip force based model were valid to support the laboratory studies on the longitudinal comfort of rapid transit trains.

  11. Kinetic measurements of hand motor impairments after mild to moderate stroke using grip control tasks.

    Science.gov (United States)

    Ye, Yu; Ma, Le; Yan, Tiebin; Liu, Huihua; Wei, Xijun; Song, Rong

    2014-05-11

    The aim of this study is to investigate quantitative outcome measurements of hand motor performance for subjects after mild to moderate stroke using grip control tasks and characterize abnormal flexion synergy of upper extremities after stroke. A customized dynamometer with force sensors was used to measure grip force and calculate rotation torque during the sub-maximal grip control tasks. The paretic and nonpartic sides of eleven subjects after stroke and the dominant sides of ten healthy persons were tested. Their maximal voluntary grip force was measured and used to set sub-maximal grip control tasks at three different target force levels. Force control ability was characterized by the maximal grip force, mean force percentage, coefficient of variation (CV), target deviation ratio (TDR), and rotation torque ratio (RTR). The motor impairments of subjects after stroke were also evaluated using the Fugl-Meyer assessment for upper extremity (FMA-UE) and Wolf Motor Function Test (WMFT). Maximal grip force of the paretic side was significantly reduced as compared to the nonparetic side and the healthy group, while the difference of maximal grip force between the nonparetic side and the healthy group was not significant. TDR and RTR increased for all three groups with increasing target force level. There were significant differences of CV, TDR and RTR between the paretic side and the healthy group at all the force levels. CV, TDR and RTR showed significant negative correlations with FMA-UE and WMFT at 50% of maximum grip force. This study designed a customized dynamometer together with an innovative measurement, RTR, to investigate the hand motor performance of subjects after mild to moderate stroke during force control tasks. And stroke-induced abnormal flexion synergy of wrist and finger muscles could be characterized by RTR. This study also identified a set of kinetic parameters which can be applied to quantitatively assess the hand motor function of subjects after

  12. Temporary threshold shift of vibratory sensation induced by a vibrating handle and its gripping force.

    Science.gov (United States)

    Nishiyama, K; Taoda, K; Yamashita, H; Watanabe, S

    1996-01-01

    This study examines the effect of the force with which a vibrating handle is gripped on the temporary threshold shift of vibratory sensation (TTSv) induced by hand-arm vibration. Six healthy subjects gripped a handle vibrating with a 1.3 octave-band vibration, with a central frequency of 200 Hz and an intensity of 39.2 m/s2. Exposure was for 1 min and 10 min, respectively. Gripping forces for the 1-min exposure were 5 N, 10 N, 40 N and 80 N, respectively, with 0 N push-pull force. Gripping forces for the 10-min exposure were the same as for the 1-min exposure but omitting 80 N. The vibratory sensation threshold at 125 Hz was measured before and after exposure of an exposed fingertip to vibration. The differences measured determine TTSv.t at time t. TTSv.t determines TTSv.0, that is, the temporary threshold shift of vibratory sensation immediately after exposure to vibration according to the estimate made on the basis of the preceding study. The same experimental conditions were repeated 3 times on different days in a soundproof and thermoregulated room. Our findings show that TTSv increases significantly with increasing gripping force. We also determined the quantitative relationships between TTSv.0 and gripping force as described by the equation TTSv.0 = exp(kf x F + Cf). where kt and Cf are constants and F is gripping force. This study revealed the importance of ergonomic design in reducing the force with which a vibrating handle is gripped to prevent an adverse effect of local vibration. The equation devised may help in the quantitative assessment of the effect of reduced gripping force.

  13. Anticipatory grip force between 1 and 3g

    Science.gov (United States)

    White, Olivier; Van Loon, ing.. Jack J. W. A.; Thonnard, Jean-Louis; Hermsdorfer, Joachim; Lefevre, Philippe

    One remarkable capacity of utilizing common tools appropriately as soon as we grasp them relies on the ability to determine in advance the grip force (GF) required to handle them in relation to their mechanical properties and the surrounding environment. This anticipatory strategy avoids the uncompressible delays in the feedback system. The predictive control of GF is made possible because the nervous system can learn, store and then select the internal representations of the dynamics of innumerable objects, known as internal models. Beside this flexibility, the nervous system's ability to learn different task dynamics is often limited in classical robotic experiments The environment itself can be profoundly modified in altered gravity or centrifugation. The few studies that investigated motor adaptation in such contexts did not consider the interaction between gravitational phases and even less the transitions across environments. Here, we tested subject's abilities to adapt to levels of gravitational fields generated by a human centrifuge. In Experiment 1, seven subjects performed 4 lifting trials in each gravitational phase (1 to 2.5g and then 2.5 to 1g by steps of 0.5g) with a 0.12 kg instrumented object. In Experiment 2, six subjects performed vertical oscillations of the object during transitions between 1 and 3g (0.5g steps, ascending and descending phases, profile repeated twice). We continuously measured GF, load force (LF) and ambient gravity. We hypothesized that participants were able to predictively adjust GF to the new environment. In Experiment 1, participants adjusted their GF proportionally to gravity and decreased GF across trials within a given gravitational environment. Preload phases decreased over time from 300ms to 50ms irrespective of gravity. We quantified the abilities of participants to switch across environments by subtracting GF recorded in the last trial in the current gravity level from GF during the first trial in the new environment

  14. The elusive thermotropic biaxial nematic phase in rigid bent-core molecules

    Indian Academy of Sciences (India)

    Bharat R Acharya; Andrew Primak; Theo J Dingemans; Edward T Samulski; Satyendra Kumar

    2003-08-01

    The biaxial nematic liquid crystalline phase was predicted several decades ago. Several vigorous attempts to find it in various systems resulted in mis-identifications. The results of X-ray diffraction and optical texture studies of the phases exhibited by rigid bent-core molecules derived from 2,5-bis-(-hydroxyphenyl)-1,3,4-oxadiazole reveal that the biaxial nematic phase is formed by three compounds of this type. X-ray diffraction studies reveal that the nematic phase of these compounds has the achiral symmetry D2h, in which the overall long axes of the molecules are oriented parallel to each other to define the major axis of the biaxial phase. The apex of the bent-cores defines the minor axis of this phase along which the planes containing the bent-cores of neighboring molecules are oriented parallel to each other.

  15. Measurement and models of bent KAP(001) crystal integrated reflectivity and resolution (invited)

    Science.gov (United States)

    Loisel, G. P.; Wu, M.; Stolte, W.; Kruschwitz, C.; Lake, P.; Dunham, G. S.; Bailey, J. E.; Rochau, G. A.

    2016-11-01

    The Advanced Light Source beamline-9.3.1 x-rays are used to calibrate the rocking curve of bent potassium acid phthalate (KAP) crystals in the 2.3-4.5 keV photon-energy range. Crystals are bent on a cylindrically convex substrate with a radius of curvature ranging from 2 to 9 in. and also including the flat case to observe the effect of bending on the KAP spectrometric properties. As the bending radius increases, the crystal reflectivity converges to the mosaic crystal response. The X-ray Oriented Programs (xop) multi-lamellar model of bent crystals is used to model the rocking curve of these crystals and the calibration data confirm that a single model is adequate to reproduce simultaneously all measured integrated reflectivities and rocking-curve FWHM for multiple radii of curvature in both 1st and 2nd order of diffraction.

  16. Deformation mechanisms of bent Si nanowires governed by the sign and magnitude of strain

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Lihua, E-mail: wlh@bjut.edu.cn, E-mail: xdhan@bjut.edu.cn, E-mail: j.zou@uq.edu.au [Beijing Key Lab of Microstructure and Property of Advanced Material, Institute of Microstructure and Properties of Advanced Materials, Beijing University of Technology, Beijing 100124 (China); Materials Engineering, The University of Queensland, Brisbane, QLD 4072 (Australia); Kong, Deli; Xin, Tianjiao; Shu, Xinyu; Zheng, Kun; Xiao, Lirong; Sha, Xuechao; Lu, Yan; Han, Xiaodong, E-mail: wlh@bjut.edu.cn, E-mail: xdhan@bjut.edu.cn, E-mail: j.zou@uq.edu.au [Beijing Key Lab of Microstructure and Property of Advanced Material, Institute of Microstructure and Properties of Advanced Materials, Beijing University of Technology, Beijing 100124 (China); Zhang, Ze [Department of Materials Science, Zhejiang University, Hangzhou 310008 (China); Zou, Jin, E-mail: wlh@bjut.edu.cn, E-mail: xdhan@bjut.edu.cn, E-mail: j.zou@uq.edu.au [Materials Engineering, The University of Queensland, Brisbane, QLD 4072 (Australia); Centre for Microscopy and Microanalysis, The University of Queensland, Brisbane, QLD 4072 (Australia)

    2016-04-11

    In this study, the deformation mechanisms of bent Si nanowires are investigated at the atomic scale with bending strain up to 12.8%. The sign and magnitude of the applied strain are found to govern their deformation mechanisms, in which the dislocation types (full or partial dislocations) can be affected by the sign (tensile or compressive) and magnitude of the applied strain. In the early stages of bending, plastic deformation is controlled by 60° full dislocations. As the bending increases, Lomer dislocations can be frequently observed. When the strain increases to a significant level, 90° partial dislocations induced from the tensile surfaces of the bent nanowires are observed. This study provides a deeper understanding of the effect of the sign and magnitude of the bending strain on the deformation mechanisms in bent Si nanowires.

  17. Channeling of high-energy particles in bent crystals - Experiments at the CERN SPS

    Science.gov (United States)

    Baurichter, A.; Biino, C.; Clément, M.; Doble, N.; Elsener, K.; Fidecaro, G.; Freund, A.; Gatignon, L.; Grafström, P.; Gyr, M.; Hage-Ali, M.; Herr, W.; Keppler, P.; Kirsebom, K.; Klem, J.; Major, J.; Medenwaldt, R.; Mikkelsen, U.; Møller, S. P.; Siffert, P.; Uggerhøj, E.; Vilakazi, Z. Z.; Weisse, E.

    2000-04-01

    During the latest decade, experiments have been performed at the CERN SPS to investigate the use of high-energy channeled nuclei in bent crystals for extraction, beam splitting and beam bending. An understanding of channeling in a bent crystal with extraction and deflection efficiencies for different energies, crystal types and ions has been developed. Furthermore, the long-standing question of radiation damage has been addressed with encouraging outcome. This makes extrapolations possible for the construction of, e.g., an extraction device for the LHC at CERN, RHIC at Brookhaven or new splitting elements in high-energy beams.We present the main results obtained and discuss existing and future applications of bent crystals in high-energy physics.

  18. JPL Genesis and Rapid Intensification Processes (GRIP) Portal

    Science.gov (United States)

    Knosp, Brian W.; Li, P. Peggy; Vu, Quoc A.; Turk, Francis J.; Shen, Tsae-Pyng J.; Hristova-Veleva, Svetla M.; Licata, Stephen J.; Poulsen, William L.

    2012-01-01

    Satellite observations can play a very important role in airborne field campaigns, since they provide a comprehensive description of the environment that is essential for the experiment design, flight planning, and post-experiment scientific data analysis. In the past, it has been difficult to fully utilize data from multiple NASA satellites due to the large data volume, the complexity of accessing NASA s data in near-real-time (NRT), as well as the lack of software tools to interact with multi-sensor information. The JPL GRIP Portal is a Web portal that serves a comprehensive set of NRT observation data sets from NASA and NOAA satellites describing the atmospheric and oceanic environments related to the genesis and intensification of the tropical storms in the North Atlantic Ocean. Together with the model forecast data from four major global atmospheric models, this portal provides a useful tool for the scientists and forecasters in planning and monitoring the NASA GRIP field campaign during the 2010 Atlantic Ocean hurricane season. This portal uses the Google Earth plug-in to visualize various types of data sets, such as 2D maps, wind vectors, streamlines, 3D data sets presented at series of vertical cross-sections or pointwise vertical profiles, and hurricane best tracks and forecast tracks. Additionally, it allows users to overlap multiple data sets, change the opacity of each image layer, generate animations on the fly with selected data sets, and compare the observation data with the model forecast using two independent calendars. The portal also provides the capability to identify the geographic location of any point of interest. In addition to supporting the airborne mission planning, the NRT data and portal will serve as a very rich source of information during the post-field campaign analysis stage of the airborne experiment. By including a diverse set of satellite observations and model forecasts, it provides a good spatial and temporal context for the

  19. From antiferroelectricity to ferroelectricity in smectic mesophases formed by bent-core molecules

    Indian Academy of Sciences (India)

    Carsten Tschierske; Gert Dantlgraber

    2003-08-01

    This contribution gives an overview of ferroelectric switching liquid crystalline phases formed by bent-core molecules. First a description of some general principles behind the mesophase formation within bent-core systems will be given, followed by a short review of the mesophase structures formed by such molecules. Then, different classes of ferroelectric switching bent-core mesogens will be described. This type of switching behaviour has been reported for several subtypes of polar smectic phases (B2, B5, B7 and SmCG) and recently for columnar mesophases. In this discussion particular attention will be made to polyphilic bent-core molecules, composed of three incompatible units, a bent aromatic core, alkyl chains and an oligosiloxane unit. The importance of the decoupling of the layers into microsegregated sublayers for the ferroelectric organisation is discussed. Many of the ferroelectric switching mesophases show dark textures with distinct regions of opposite chirality in their ground states. It is discussed that this might be due to a helical superstructure formed as a result of an escape from macroscopic polar order. Hence, the materials themselves are not ferroelectric in the ground state, but upon alignment within an electric field in the measuring cells the ferroelectric states are stabilised by surface interactions, leading to a ferroelectric switching system. The designing principle was extended to mesogenic dimers with bent-core structural units. For these compounds, depending on the number of dimethylsiloxane units in the spacer either ferroelectric or antiferroelectric switching was observed, whereby the effect of parity is reversed to that observed for conventional calamitic dimesogens. Finally, a carbosilane-based first generation dendrimer is reported. It shows a ferroelectric switching phase, for which a non-correlated organisation of tilted polar smectic layers is proposed (SmCPR).

  20. Microbiota bacteriana asociada a los cultivos de dos especies de diatomeas bentónicas.

    OpenAIRE

    Hernández-Zulueta, Joicye; Leal, Sylvia; Loza, Sandra

    2014-01-01

    Las diatomeas bentónicas forman biopelículas debido a las sustancias que secretan, que les permite mantenerse adheridas al sustrato. A ellas se asocian bacterias que, dada las condiciones no axénicas de los cultivos, pueden alterar su valor nutricional. El objetivo del presente trabajo fue caracterizar la microbiota bacteriana asociada a los cultivos de las microalgas bentónicas Navicula germanopolonica y Amphora sp., especies utilizadas para la precría del camarón en cultivo. Se aislaron e i...

  1. Parallel code NSBC: Simulations of relativistic nuclei scattering by a bent crystal

    Science.gov (United States)

    Babaev, A. A.

    2014-01-01

    The presented program was designed to simulate the passage of relativistic nuclei through a bent crystal. Namely, the input data is related to a nuclei beam. The nuclei move into the crystal under planar channeling and quasichanneling conditions. The program realizes the numerical algorithm to evaluate the trajectory of nucleus in the bent crystal. The program output is formed by the projectile motion data including the angular distribution of nuclei behind the crystal. The program could be useful to simulate the particle tracking at the accelerator facilities used the crystal collimation systems. The code has been written on C++ and designed for the multiprocessor systems (clusters).

  2. Shuttle Ku-band bent-pipe implementation considerations. [for Space Shuttle digital communication systems

    Science.gov (United States)

    Batson, B. H.; Seyl, J. W.; Huth, G. K.

    1977-01-01

    This paper describes an approach for relay of data-modulated subcarriers from Shuttle payloads through the Shuttle Ku-band communications subsystem (and subsequently through a tracking and data relay satellite system to a ground terminal). The novelty is that a channel originally provided for baseband digital data is shown to be suitable for this purpose; the resulting transmission scheme is referred to as a narrowband bent-pipe scheme. Test results demonstrating the validity of the narrowband bent-pipe mode are presented, and limitations on system performance are described.

  3. Possibility of high efficient beam extraction from the CERN SPS with a bent crystal. Simulation results

    Science.gov (United States)

    Scandale, W.; Kovalenko, A. D.; Taratin, A. M.

    2017-03-01

    The extraction of the SPS beam of 270 GeV/c protons assisted by a bent crystal was studied by simulation. Two methods for delivering the SPS beam onto a crystal were considered: transverse diffusion and orbit bump of the beam. It was shown that the main condition for high efficient beam extraction with a bent crystal, which is a small divergence of the incident beam, can be fulfilled. Extraction efficiency up to 99% can be reached for both methods of the beam delivering. The irradiation of the electrostatic septum wires during the beam extraction can be considerably reduced.

  4. Dual Symmetry in Bent-Core Liquid Crystals and Unconventional Superconductors

    Directory of Open Access Journals (Sweden)

    Vladimir Lorman

    2010-01-01

    Full Text Available We extend the Landau theory of bent-core mesophases and d-wave high-Tc superconductors by considering additional secondary pseudo-proper order parameters. These systems exhibit a remarkable analogy relating their symmetry groups, lists of phases, and an infinite set of physical tensors. This analogy lies upon an internal dual structure shared by the two theories. We study the dual operator transforming rotations into translations in liquid crystals, and gauge symmetries into rotations in superconductors. It is used to classify the bent-core line defects, and to analyze the electronic gap structure of lamellar d-wave superfluids.

  5. Energy funneling in a bent chain of Morse oscillators with long-range coupling

    DEFF Research Database (Denmark)

    Larsen, Peter Ulrik Vingaard; Christiansen, Peter Leth; Bang, Ole;

    2004-01-01

    A bent chain of coupled Morse oscillators with long-range dispersive interaction is considered. Moving localized excitations may be trapped in the bending region. Thus chain geometry acts like an impurity. An energy funneling effect is observed in the case of random initial conditions.......A bent chain of coupled Morse oscillators with long-range dispersive interaction is considered. Moving localized excitations may be trapped in the bending region. Thus chain geometry acts like an impurity. An energy funneling effect is observed in the case of random initial conditions....

  6. High efficiency multi-pass proton beam extraction with a bent crystal at the SPS

    Science.gov (United States)

    Altuna, X.; Bussa, M. P.; Carboni, G.; Dehning, B.; Elsener, K.; Ferrari, A.; Fidecaro, G.; Freund, A.; Guinand, R.; Gyr, M.; Herr, W.; Klem, J.; Laffin, M.; Lanceri, L.; Mikkelsen, U.; Møller, S. P.; Scandale, W.; Tosello, F.; Uggerhøj, E.; Vuagnin, G.; Weisse, E.; Weisz, S.

    1995-02-01

    Recent measurements of 120 GeV proton extraction by means of a bent silicon crystal at the CERN-SPS accelerator are summarized. The existence of multi-pass extraction has been proven by blocking first-pass extraction: using a crystal covered with an amorphous layer, extracted beam with high efficiency was observed, which provides a direct proof for the importance of the multi-pass mechanism. This opens new possibilities in the design and optimization of a bent crystal extraction scheme.

  7. Deflection of 450 GeV protons by planar channeling in a bent silicon crystal

    Science.gov (United States)

    Jensen, B. N.; Møller, S. P.; Uggerhøj, E.; Worm, T.; Atherton, H. W.; Clément, M.; Doble, N.; Elsener, K.; Gatignon, L.; Grafström, P.; Jeanneret, J. B.; Hage-Ali, M.; Siffert, P.

    1992-08-01

    A 450 GeV proton beam has been bent by various angles from 4 to 14 mrad using planar channeling in a (111) silicon crystal. Detailed investigations of the deflected beam as well as the unbent and scattered particles have been performed. The incident beam had a divergence of about 35 μrad (FWHM). 20% of the protons hitting the crystal front face were found to be initially channeled. The measured bending efficiencies range from 5 to 2% (for increasing deflection angles) are compared to theoretical estimates including surface acceptance and dechanneling in bent silicon crystals.

  8. On the energy dependence of proton beam extraction with a bent crystal

    Science.gov (United States)

    Arduini, G.; Elsener, K.; Fidecaro, G.; Gyr, M.; Herr, W.; Klem, J.; Mikkelsen, U.; Weisse, E.

    1998-03-01

    Proton beam extraction from the CERN SPS by means of a bent silicon crystal is reported at three different energies, 14 GeV, 120 GeV and 270 GeV. The experimental results are compared to computer simulations which contain a sound model of the SPS accelerator as well as the channeling phenomena in bent crystals. The overall energy dependence of crystal assisted proton beam extraction is understood and provides the basis to discuss such a scheme for future accelerators. © 1998

  9. Deflection of 450 GeV protons by planar channeling in a bent silicon crystal

    Energy Technology Data Exchange (ETDEWEB)

    Jensen, B.N.; Moeller, S.P.; Uggerhoej, E.; Worm, T. (Inst. for Synchrotron Radiation, Aarhus Univ. (Denmark)); Atherton, H.W.; Clement, M.; Doble, N.; Elsener, K.; Gatignon, L.; Grafstroem, P.; Jeanneret, J.B. (European Organization for Nuclear Research (CERN), Geneva (Switzerland)); Hage-Ali, M.; Siffert, P. (Centre de Recherches Nucleaires, 67 - Strasbourg (France))

    1992-08-01

    A 450 GeV proton beam has been bent by various angles from 4 to 14 mrad using planar channeling in a (111) silicon crystal. Detailed investigations of the deflected beam as well as the unbent and scattered particles have been performed. The incident beam had a divergence of about 35 [mu]rad (FWHM). 20% of the protons hitting the crystal front face were found to be initially channeled. The measured bending efficiencies range from 5 to 2% (for increasing deflection angles) and are compared to theoretical estimates including surface acceptance and dechanneling in bent silicon crystals. (orig.).

  10. Body mass index, muscle strength and physical performance in older adults from eight cohort studies: the HALCyon programme.

    Directory of Open Access Journals (Sweden)

    Rebecca Hardy

    Full Text Available To investigate the associations of body mass index (BMI and grip strength with objective measures of physical performance (chair rise time, walking speed and balance including an assessment of sex differences and non-linearity.Cross-sectional data from eight UK cohort studies (total N = 16,444 participating in the Healthy Ageing across the Life Course (HALCyon research programme, ranging in age from 50 to 90+ years at the time of physical capability assessment, were used. Regression models were fitted within each study and meta-analysis methods used to pool regression coefficients across studies and to assess the extent of heterogeneity between studies.Higher BMI was associated with poorer performance on chair rise (N = 10,773, walking speed (N = 9,761 and standing balance (N = 13,921 tests. Higher BMI was associated with stronger grip strength in men only. Stronger grip strength was associated with better performance on all tests with a tendency for the associations to be stronger in women than men; for example, walking speed was higher by 0.43 cm/s (0.14, 0.71 more per kg in women than men. Both BMI and grip strength remained independently related with performance after mutual adjustment, but there was no evidence of effect modification. Both BMI and grip strength exhibited non-linear relations with performance; those in the lowest fifth of grip strength and highest fifth of BMI having particularly poor performance. Findings were similar when waist circumference was examined in place of BMI.Older men and women with weak muscle strength and high BMI have considerably poorer performance than others and associations were observed even in the youngest cohort (age 53. Although causality cannot be inferred from observational cross-sectional studies, our findings suggest the likely benefit of early assessment and interventions to reduce fat mass and improve muscle strength in the prevention of future functional limitations.

  11. Gripping during climbing of arboreal snakes may be safe but not economical

    Science.gov (United States)

    Byrnes, Greg; Jayne, Bruce C.

    2014-01-01

    On the steep surfaces that are common in arboreal environments, many types of animals without claws or adhesive structures must use muscular force to generate sufficient normal force to prevent slipping and climb successfully. Unlike many limbed arboreal animals that have discrete gripping regions on the feet, the elongate bodies of snakes allow for considerable modulation of both the size and orientation of the gripping region. We quantified the gripping forces of snakes climbing a vertical cylinder to determine the extent to which their force production favoured economy or safety. Our sample included four boid species and one colubrid. Nearly all of the gripping forces that we observed for each snake exceeded our estimate of the minimum required, and snakes commonly produced more than three times the normal force required to support their body weight. This suggests that a large safety factor to avoid slipping and falling is more important than locomotor economy. PMID:25142200

  12. Effect of Putting Grip on Eye and Head Movements During the Golf Putting Stroke

    Directory of Open Access Journals (Sweden)

    George K. Hung

    2003-01-01

    Full Text Available The objective of this article is to determine the effect of three different putting grips (conventional, cross-hand, and one-handed on variations in eye and head movements during the putting stroke. Seven volunteer novice players, ranging in age from 21 to 22 years, participated in the study. During each experimental session, the subject stood on a specially designed platform covered with artificial turf and putted golf balls towards a standard golf hole. The three different types of grips were tested at two distances: 3 and 9 ft. For each condition, 20 putts were attempted. For each putt, data were recorded over a 3-s interval at a sampling rate of 100 Hz. Eye movements were recorded using a helmet-mounted eye movement monitor. Head rotation about an imaginary axis through the top of the head and its center-of-rotation was measured by means of a potentiometer mounted on a fixed frame and coupled to the helmet. Putter-head motion was measured using a linear array of infrared phototransistors embedded in the platform. The standard deviation (STD, relative to the initial level was calculated for eye and head movements over the duration of the putt (i.e., from the beginning of the backstroke, through the forward stroke, to impact. The averaged STD for the attempted putts was calculated for each subject. Then, the averaged STDs and other data for the seven subjects were statistically compared across the three grip conditions. The STD of eye movements were greater (p < 0.1 for conventional than cross-hand (9 ft and one-handed (3 and 9 ft grips. Also, the STD of head movements were greater (p < 0.1; 3 ft for conventional than cross-hand and one-handed grips. Vestibulo-ocular responses associated with head rotations could be observed in many 9 ft and some 3 ft putts. The duration of the putt was significantly longer (p < 0.05; 3 and 9 ft for the one-handed than conventional and cross-hand grips. Finally, performance, or percentage putts made, was

  13. Adaptive grip force is modulated by subthalamic beta activity in Parkinson's disease patients

    Directory of Open Access Journals (Sweden)

    Lukas L. Imbach

    2015-01-01

    Conclusion: The time-locked suppression of beta oscillatory activity in the STN is in line with previous reports of beta ERD prior to voluntary movements. Our results show that the STN is involved in anticipatory grip force control in PD patients. The difference in the phasic beta ERD between the two tasks and the reduction of cortico-subthalamic synchronization suggests that qualitatively different neuronal network states are involved in different grip force control tasks.

  14. Improvement of handle grip using reverse engineering, CAE and Rapid Prototyping

    Directory of Open Access Journals (Sweden)

    Stoklasek Pavel

    2016-01-01

    Full Text Available The overwhelming majority of manual operations is even nowadays performed by using manual hand tools. These tools can be divided into 2 groups – hand tools designed for general use or a single-purpose hand tools for special operations. Tool described in this paper is used in assembling operation in the completion of electric motor. During the design of the existing tools the requirements for a functional part of the tool (lifespan, inability to damage the engine installation were fully considered, demands for ergonomic grip area, however, were not taken into account. Long-term use of incorrectly designed tool causes carpal tunnel syndrome, hand-arm vibration syndrome, diminished sensitivity or tingling in the fingers of workers. These difficulties can be reduced or entirely eliminated due to proper design of the grip of hand tool. Most authors focus on adjusting the grip for optimum ergonomics at individual types of grips (cylindrical, palmar, lateral, etc.. However, as already mentioned, there are tools for specific operations when the working area is limited by space or a specific type of load on the grip is needed. In some cases, it is often necessary to change the type of grip or combine different types of grips. This paper describes the design of an optimal grip of hand tool used for specific operation when assembling motors. Design of prototype mold and production of functional prototypes for ergonomics assessment directly in the workplace were realized. New design of handle should reduce the risk primarily of developing carpal tunnel in long-term use.

  15. PICK1 interacts with ABP/GRIP to regulate AMPA receptor trafficking.

    Science.gov (United States)

    Lu, Wei; Ziff, Edward B

    2005-08-04

    PICK1 and ABP/GRIP bind to the AMPA receptor (AMPAR) GluR2 subunit C terminus. Transfer of the receptor from ABP/GRIP to PICK1, facilitated by GluR2 S880 phosphorylation, may initiate receptor trafficking. Here we report protein interactions that regulate these steps. The PICK1 BAR domain interacts intermolecularly with the ABP/GRIP linker II region and intramolecularly with the PICK1 PDZ domain. Binding of PKCalpha or GluR2 to the PICK1 PDZ domain disrupts the intramolecular interaction and facilitates the PICK1 BAR domain association with ABP/GRIP. Interference with the PICK1-ABP/GRIP interaction impairs S880 phosphorylation of GluR2 by PKC and decreases the constitutive surface expression of GluR2, the NMDA-induced endocytosis of GluR2, and recycling of internalized GluR2. We suggest that the PICK1 interaction with ABP/GRIP is a critical step in controlling GluR2 trafficking.

  16. Control of grip force and vertical posture while holding an object and being perturbed.

    Science.gov (United States)

    Chen, Bing; Lee, Yun-Ju; Aruin, Alexander S

    2016-11-01

    We investigated motor control perspectives of coordinating maintenance of posture and application of grip force when holding an object and being perturbed. Ten subjects stood on the force platform holding an instrumented object in their dominant hand and were exposed to an external perturbation applied to their shoulders. Task demands were manipulated by positioning a slippery cap on top of the instrumented object. Grip force applied to the object, the object acceleration and the center of pressure (COP) were recorded and analyzed during the time intervals typical for the anticipatory (APA) and compensatory (CPA) components of postural control. Onsets of grip force were seen before the onsets of the COP displacement and initiation of movements of the handheld object during the APA phase of postural control, while the onsets of maximum grip force preceded the maximum COP displacement during the CPA phase. When the task demands increased by holding a handheld object with the slippery cap, subjects tended to generate grip force earlier and of a smaller magnitude; also, the COP displacement in the APA phase was smaller as compared to holding a handheld object only. The outcome provides a foundation for future studies of maintenance of vertical posture in people with impairments of balance and grip force control when holding an object and being perturbed.

  17. The theory of the centrifugal mechanism of feeding-in in bent crystals

    OpenAIRE

    2001-01-01

    For a particle channeled in the bent crystal planes (axes), the phenomenon of "bending dechanneling", which is a particle transition to a random state due to centrifugal force, is well known. We consider an analytical theory of the reverse phenomenon, i.e., feeding from a random state to a channeled state due to centrifugal force in a crystal with variable curvature.

  18. Channeling, volume reflection, and volume capture study of electrons in a bent silicon crystal

    DEFF Research Database (Denmark)

    Wistisen, T. N.; Uggerhoj, U. I.; Wienands, U.;

    2016-01-01

    We present the experimental data and analysis of experiments conducted at SLAC National Accelerator Laboratory investigating the processes of channeling, volume-reflection and volume-capture along the (111) plane in a strongly bent quasimosaic silicon crystal. These phenomena were investigated at...

  19. Note on the glide of a bird with wings bent downwards

    NARCIS (Netherlands)

    Sparenberg, J. A.

    2006-01-01

    This note considers the influence of the bending down of the wings of a bird on the performance of its glide. The induced drag of bent wings is compared with the induced drag of a corresponding straight wing. Numerical results are given.

  20. Laterally substituted symmetric and nonsymmetric salicylideneimine-based bent-core mesogens

    Directory of Open Access Journals (Sweden)

    Sonja Findeisen-Tandel

    2012-01-01

    Full Text Available Bent-core mesogens have gained considerable importance due to their ability to form new mesophases with unusual properties. Relationships between the chemical structure of bent-core molecules and the type and physical properties of the formed mesophases are relatively unknown in detail and differ strongly from those known for calamitic liquid crystals. In this paper symmetric and nonsymmetric five-ring salicylideneaniline-based bent-core mesogens are presented, and the effect of lateral substituents attached at the outer phenyl rings (F, Cl, Br or the central phenyl ring (CH3 on the liquid-crystalline behaviour and on the physical properties is studied. Corresponding benzylideneaniline-based compounds were additionally prepared in order to study the influence of the intramolecular hydrogen bond. The occurring mesophases were investigated by differential scanning calorimetry, polarising microscopy, X-ray diffraction and dielectric and electro-optical measurements. The paper reports on new findings with respect to the structure–property relationships of bent-core mesogens. On one hand, the disruptive effect of laterally substituted halogen atoms, F, Cl and Br, on the mesophase behaviour of three isomeric series was much lower than expected. On the other hand, an increase of the clearing temperature by 34 K was observed, caused by small lateral substituents. The electro-optical behaviour, especially the type of polar switching and corresponding molecular movements, is sensitive to variations in the molecular structure.

  1. What did we learn from the extraction experiments with bent crystals at the CERN SPS?

    CERN Document Server

    Elsener, K; Gyr, Marcel; Herr, Werner; Klem, J T; Mikkelsen, U; Weisse, E

    1998-01-01

    The feasibility and properties of particle extraction from an accelerator by means of a bent crystal were studied extensively at the CERN SPS. The main results of the experiments are presented. This includes the evidence for multipass extraction of heavy ions. These results are compared with theoretical expectations and computer simulations.

  2. Note on the glide of a bird with wings bent downwards

    NARCIS (Netherlands)

    Sparenberg, J. A.

    This note considers the influence of the bending down of the wings of a bird on the performance of its glide. The induced drag of bent wings is compared with the induced drag of a corresponding straight wing. Numerical results are given.

  3. Observation of Proton Reflection on Bent Silicon Crystals at the CERN SPS

    CERN Document Server

    Scandale, Walter

    2007-01-01

    We report the observation of the so-called volume reflection effect with 400 GeV/c protons interacting with bent silicon crystals in the H8 beam line performed by the H8RDD22 Collaboration at the CERN SPS. The volume reflection is an effect of the same nature of the particle channeling among the crystalline planes of a bent crystal. The reflection occurs at the tangency point of a particle trajectory with the bent crystalline planes where the transverse component of the particle momentum is reversed. The measurements were realized with a high spatial resolution detector mainly based on silicon microstrips showing the effect on particle trajectories of bent silicon crystals in several configurations. The proton beam was deviated in a direction opposite to that of channeling by 12-14 mrad, which is 1.3 times the critical angle, with an efficiency greater than 97% in a range of the proton-to-crystal incident angle as wide as the bending angle of crystallographic planes. This evidence opens new perspectives for m...

  4. Two-dimensional refractive index and stresses profiles of a homogenous bent optical fiber.

    Science.gov (United States)

    Ramadan, W A; Wahba, H H; Shams El-Din, M A

    2014-11-01

    We present a significant contribution to the theory of determining the refractive index profile of a bent homogenous optical fiber. In this theory we consider two different processes controlling the index profile variations. The first is the linear index variation due to stress along the bent radius, and the second is the release of this stress on the fiber surface. This release process is considered to have radial dependence on the fiber radius. These considerations enable us to construct the index profile in two dimensions normal to the optical axis, considering the refraction of light rays traversing the fiber. This theory is applied to optical homogenous bent fiber with two bending radii when they are located orthogonal to the light path of the object arm in the holographic setup (like the Mach-Zehnder interferometer). Digital holographic phase shifting interferometry is employed in this study. The recorded phase shifted holograms have been combined, reconstructed, and processed to extract the phase map of the bent optical fiber. A comparison between the extracted optical phase differences and the calculated one indicates that the refractive index profile variation should include the above mentioned two processes, which are considered as a response for stress distribution across the fiber's cross section. The experimentally obtained refractive index profiles provide the stress induced birefringence profile. Thus we are able to present a realistic induced stress profile due to bending.

  5. Priming for Improved Hand Strength in Persons with Chronic Tetraplegia: A Comparison of Priming-Augmented Functional Task Practice, Priming Alone, and Conventional Exercise Training

    Science.gov (United States)

    Gomes-Osman, Joyce; Tibbett, Jacqueline A.; Poe, Brandon P.; Field-Fote, Edelle C.

    2017-01-01

    Many everyday tasks cannot be accomplished without adequate grip strength, and corticomotor drive to the spinal motoneurons is a key determinant of grip strength. In persons with tetraplegia, damage to spinal pathways limits transmission of signals from motor cortex to spinal motoneurons. Corticomotor priming, which increases descending drive, should increase corticospinal transmission through the remaining spinal pathways resulting in increased grip strength. Since the motor and somatosensory cortices share reciprocal connections, corticomotor priming may also have potential to influence somatosensory function. The purpose of this study was to assess changes in grip (precision, power) force and tactile sensation associated with two different corticomotor priming approaches and a conventional training approach and to determine whether baseline values can predict responsiveness to training. Participants with chronic (≥1 year) tetraplegia (n = 49) were randomized to one of two corticomotor priming approaches: functional task practice plus peripheral nerve somatosensory stimulation (FTP + PNSS) or PNSS alone, or to conventional exercise training (CET). To assess whether baseline corticospinal excitability (CSE) is predictive of responsiveness to training, in a subset of participants, we assessed pre-intervention CSE of the thenar muscles. Participants were trained 2 h daily, 5 days/week for 4 weeks. Thirty-seven participants completed the study. Following intervention, significant improvements in precision grip force were observed in both the stronger and weaker hand in the FTP + PNSS group (effect size: 0.51, p = 0.04 and 0.54, p = 0.03, respectively), and significant improvements in weak hand precision grip force were associated with both PNSS and CET (effect size: 0.54, p = 0.03 and 0.75, p = 0.02, respectively). No significant changes were observed in power grip force or somatosensory scores in any group. Across all groups

  6. Priming for Improved Hand Strength in Persons with Chronic Tetraplegia: A Comparison of Priming-Augmented Functional Task Practice, Priming Alone, and Conventional Exercise Training.

    Science.gov (United States)

    Gomes-Osman, Joyce; Tibbett, Jacqueline A; Poe, Brandon P; Field-Fote, Edelle C

    2016-01-01

    Many everyday tasks cannot be accomplished without adequate grip strength, and corticomotor drive to the spinal motoneurons is a key determinant of grip strength. In persons with tetraplegia, damage to spinal pathways limits transmission of signals from motor cortex to spinal motoneurons. Corticomotor priming, which increases descending drive, should increase corticospinal transmission through the remaining spinal pathways resulting in increased grip strength. Since the motor and somatosensory cortices share reciprocal connections, corticomotor priming may also have potential to influence somatosensory function. The purpose of this study was to assess changes in grip (precision, power) force and tactile sensation associated with two different corticomotor priming approaches and a conventional training approach and to determine whether baseline values can predict responsiveness to training. Participants with chronic (≥1 year) tetraplegia (n = 49) were randomized to one of two corticomotor priming approaches: functional task practice plus peripheral nerve somatosensory stimulation (FTP + PNSS) or PNSS alone, or to conventional exercise training (CET). To assess whether baseline corticospinal excitability (CSE) is predictive of responsiveness to training, in a subset of participants, we assessed pre-intervention CSE of the thenar muscles. Participants were trained 2 h daily, 5 days/week for 4 weeks. Thirty-seven participants completed the study. Following intervention, significant improvements in precision grip force were observed in both the stronger and weaker hand in the FTP + PNSS group (effect size: 0.51, p = 0.04 and 0.54, p = 0.03, respectively), and significant improvements in weak hand precision grip force were associated with both PNSS and CET (effect size: 0.54, p = 0.03 and 0.75, p = 0.02, respectively). No significant changes were observed in power grip force or somatosensory scores in any group. Across all groups

  7. Efeito da preensão manual sobre o equilíbrio de judocas Effect of hand grip on the balance of judokas

    Directory of Open Access Journals (Sweden)

    Jonathan Ache Dias

    2011-06-01

    Full Text Available O objetivo deste estudo foi verificar se existe efeito da preensão manual máxima (o ato de realizar ou não a preensão sobre o controle do equilíbrio de judocas em postura restrita, além de verificar se existe correlação entre a força de preensão manual (FPM e o controle do equilíbrio. Foram avaliados sete judocas com um dinamômetro e uma plataforma estabilométrica sendo mensuradas, concomitantemente, a FPM e o centro de pressão (CP. Foi verificado que até 80% da variabilidade do CP pode ser atrelada a preensão manual indicando que a mesma gera perturbações no controle do equilíbrio. Entretanto, foram encontradas correlações (r = 0,348 até 0,816 entre a FPM e o deslocamento do CP. Com isso pode-se concluir que, apesar da preensão manual gerar perturbações no equilíbrio, seu comportamento parece estar relacionado com os movimentos do corpo realizados para manter o equilíbrio, indicando uma possível correlação entre esses fenômenos.The purpose of this study was to verify if there is an effect of maximum hand grip (the act of performing or not the hand grip on the balance control of judokas in a restrict posture, and also to verify if there is a correlation between the hand grip strength (HGS and the balance control. Seven judokas were evaluated with a dynamometer and a stabilometric force platform, being measured, at the same time, the HGS and the center of pressure (COP. It was found that up to 80% of the COP variability was related to the hand grip demonstrating that it generates perturbations to the balance control. However, It was found correlations (r = 0,348 to 0,816 between de HGS and de COP displacement. With that, it can be concluded that, despite the hand grip generating perturbation on the balance, its behavior appears to be related to the body movements performed to sustain balance, indicating a possible correlation between this phenomenons.

  8. Outcomes of torsional microcoaxial phacoemulsification performed by 12-degree and 22-degree bent tips.

    Science.gov (United States)

    Helvacioglu, Firat; Yeter, Celal; Tunc, Zeki; Sencan, Sadik

    2013-08-01

    To compare the safety and efficacy of Ozil Intelligent Phaco torsional microcoaxial phacoemulsification surgeries performed with 12-degree and 22-degree bent tips using the Infiniti Vision System. Maltepe University School of Medicine Department of Ophthalmology, Istanbul, Turkey. Comparative case series. Eyes were assigned to 2.2 mm microcoaxial phacoemulsification using the torsional mode with a 22-degree bent tip (Group 1) or a 12-degree bent tip (Group 2). The primary outcome measures were ultrasound time (UST), cumulative dissipated energy (CDE), longitudinal and torsional ultrasound (US) amplitudes, mean surgical time, mean volume of balanced salt solution used, and surgical complications. Both groups included 45 eyes. The mean UST, CDE, longitudinal US amplitude, and torsional US amplitude were 65 seconds ± 27.23 (SD), 11.53 ± 6.99, 0.22 ± 0.26, and 42.86 ± 15.64, respectively, in Group 1 and 84 ± 45.04 seconds, 16.68 ± 10.66, 0.48 ± 0.68, and 46.27 ± 14.74, respectively, in Group 2. The mean UST, CDE, and longitudinal amplitudes were significantly lower in Group 1 (P=.003, P=.008, and P=.022, respectively). The mean volume of balanced salt solution was 73.33 ± 28.58 cc in Group 1 and 82.08 ± 26.21 cc in Group 2 (P=.134). Torsional phacoemulsification performed with 22-degree bent tips provided more effective lens removal than 12-degree bent tips, with a lower UST and CDE. Copyright © 2013 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  9. Analysis of the Static Strength and Relative Endurance of Women Athletes

    Science.gov (United States)

    Heyward, Vivian; McCreary, Leslie

    1977-01-01

    Investigations of static strength and relative endurance of the grip muscles of women athletes revealed that mean endurance time was significantly greater than for men. Results were discussed in light of evidence suggesting possible sex differences in muscle hypertrophy, capillarization of muscle tissue, critical occluding tension level, and…

  10. A new family of four-ring bent-core nematic liquid crystals with highly polar transverse and end groups

    Directory of Open Access Journals (Sweden)

    Kalpana Upadhyaya

    2013-01-01

    Full Text Available Non-symmetrically substituted four-ring achiral bent-core compounds with polar substituents, i.e.., chloro in the bent or transverse direction in the central core and cyano in the lateral direction at one terminal end of the molecule, are designed and synthesized. These molecules possess an alkoxy chain attached at only one end of the bent-core molecule. The molecular structure characterization is consistent with data from elemental and spectroscopic analysis. The materials thermal behaviour and phase characterization have been investigated by differential scanning calorimetry and polarizing microscopy. All the compounds exhibit a wide-ranging monotropic nematic phase.

  11. AtGRIP protein locates to the secretory vesicles of trans Golgi-network in Arabidopsis root cap cells

    Institute of Scientific and Technical Information of China (English)

    CHEN Ying; ZHANG Wei; ZHAO Lei; LI Yan

    2008-01-01

    GRIP domain proteins, locating to the trans-Golgi network, are thought to play an essential role in Golgi apparatus trafficking in yeast and animal cells. In the present study, AtGRIP cDNA was amplified by reverse transcriptase PCR from RNA isolated from Arabidopsis seedling. The GST fusion protein of AtGRIP was affinity-purified and its rabbit polyclonal antibody was obtained. Immuno-blotting with the purified anti-AtGRIP polyclonal antibody demonstrated that the molecular mass of AtGRIP protein is about 92 kD, and its expression is not tissue-specific in Arabidopsis. Immunoflourescent labeling and confocal microscopy revealed that the AtGRIP protein was co-localized with Golgi stacks in Arabidop-sis root cells. Immuno-gold labeling and electron microscopy observation showed that AtGRIP protein was mainly located to the membrane of the secretory vesicles of trans-Golgi network in Arabidopsis root cap cells. Taken together, these results indicate that the localization of GRIP domain proteins be-tween plants and animal cells are conserved. These results also suggest that the AtGRIP may be in-volved in regulating the formation or sorting of Golgi-associated vesicles in plant cells.

  12. Grip type and task goal modify reach-to-grasp performance in post-stroke hemiparesis

    Science.gov (United States)

    Schaefer, Sydney Y.; DeJong, Stacey L.; Cherry, Kendra M.; Lang, Catherine E.

    2011-01-01

    This study investigated whether grip type and/or task goal influenced reaching and grasping performance in post-stroke hemiparesis. Sixteen adults with post-stroke hemiparesis and twelve healthy adults reached to and grasped a cylindrical object using one of two grip types (3-finger or palmar) to achieve one of two task goals (hold or lift). Performance of the stroke group was characteristic of hemiparetic limb movement during reach-to-grasp, with more curved handpaths and slower velocities compared to the control group. These effects were present regardless of grip type or task goal. Other measures of reaching (reach time and reach velocity at object contact) and grasping (peak thumb-index finger aperture during the reach and peak grip force during the grasp) were differentially affected by grip type, task goal, or both, despite the presence of hemiparesis, providing new evidence that changes in motor patterns after stroke may occur to compensate for stroke-related motor impairment. PMID:22357103

  13. Grip pressure distributions and associated variability in golf: a two-club comparison.

    Science.gov (United States)

    Langlais, Sean M; Broker, Jeffrey P

    2014-06-01

    Teaching and playing professionals offer multiple theories concerning the manner in which forces should be applied to the handle of the club during the golf swing. This study extends recent research concerning grip pressures and forces in golf, with the purpose of exploring the similarities and differences between force profiles for a 7-iron and driver swung by proficient golfers. A secondary purpose was to further analyze the way that golfers use grip forces to manipulate the club. Grip forces were measured on eight low handicap golfers (USGA indexes 0 to 7) swinging their own 7-irons and drivers. In total, lead-hand and trail-hand grip forces were isolated as well as anatomically specific forces within the hands. Force profile variability across multiple swings for each golfer and between golfers characterized consistencies and important differences. Correlations between 7-iron and driver force profiles characterized force 'signatures.' The data highlight large fluctuations in grip forces during the swing. Marked differences between participants were observed, involving force magnitudes and phasing. Dominant forces arose primarily from the lead hand, specifically the last three fingers. Force profiles were highly repeatable across swings for a golfer (standard deviations high (r2 = 0.86). Notably, within swing force variability was greatest during club acceleration, but dramatically decreased at impact.

  14. Proposed technique for inguinal hernia repair with self-gripping mesh: avoiding fixation to undesired structures.

    Science.gov (United States)

    Porrero, J L; Cano-Valderrama, O; Castillo, M J; Alonso, M T

    2015-10-01

    Self-gripping meshes have been developed to avoid fixing sutures during inguinal hernia repair. Operative time is shorter when using a self-gripping mesh than with conventional Lichtenstein repair. However, these meshes can be difficult to handle because they fix to undesired structures. The aim of this report is to describe a new technique to avoid this problem. Inguinal hernia dissection is made as usual. Once dissection is finished, a Parietex ProGrip(®) (Covidien, Dublin, Ireland) flat sheet mesh is cut depending on the size needed. A small split is made between the lower and medium third of the mesh to mark where the split for the spermatic cord will be. Using this mark, the upper third of the mesh is folded over the medium third, hiding the microgrips that make this a self-gripping mesh. In this way, only the lower third of the mesh has the microgrips exposed and the mesh can be fixed to the pubic bone and inguinal ligament without fixation to undesired structures. Once the lower third of the mesh is fixed, the split for the spermatic cord is completed and the upper part of the mesh is passed below the spermatic cord. Then, the mesh is unfolded to expose the microgrips again and the medium and upper third of the mesh are descended to its final position. This proposed technique for inguinal hernia repair with self-gripping mesh makes the surgery easier, avoiding mesh fixation to undesired structures.

  15. Slip detection and grip adjustment using optical tracking in prosthetic hands.

    Science.gov (United States)

    Roberts, Luke; Singhal, Girish; Kaliki, Rahul

    2011-01-01

    We have designed a closed loop control system that adjusts the grasping force of a prosthetic hand based on the amount of object slip detected by an optical tracking sensor. The system was designed for the i-Limb (a multi-fingered prosthetic hand from Touch Bionics Inc.) and is comprised of an optical sensor embedded inside a silicone prosthetic glove and a control algorithm. In a proof of concept study to demonstrate the effectiveness of optical tracking in slip sensing, we record slip rate while increasing the weight held in the grasp of the hand and compare two cases: grip adjustment on and grip adjustment off. The average slip rate was found to be 0.314 slips/(s · oz) without grip adjustment and 0.0411 slips/(s · oz) with grip adjustment. This paper discusses the advantages of the optical approach in slip detection and presents the experiment and results utilizing the optical sensor and grip control algorithm.

  16. Muscle strength, power and cardiorespiratory fitness are associated with bone mineral density in men aged 31-60 years

    DEFF Research Database (Denmark)

    Schwarz, Peter; Jørgensen, Niklas; Nielsen, Barbara

    2014-01-01

    -respiratory fitness with BMD at the spine and hip in men. RESULTS: The association between independent variables maximal aerobic capacity (VO(2max)), leg power and hand grip strength, and dependent variables BMD at the spine and total hip was explored in a series of linear regression models successively adjusted.......011) with BMD at total hip. CONCLUSIONS: We found that cardiorespiratory fitness was associated with BMD in men. Furthermore, hand grip strength and leg power were associated with increasing BMD at the lumbar spine and total hip in men, respectively. Further prospective studies are needed to further investigate...

  17. Estimating thumb-index finger precision grip and manipulation potential in extant and fossil primates.

    Science.gov (United States)

    Feix, Thomas; Kivell, Tracy L; Pouydebat, Emmanuelle; Dollar, Aaron M

    2015-05-06

    Primates, and particularly humans, are characterized by superior manual dexterity compared with other mammals. However, drawing the biomechanical link between hand morphology/behaviour and functional capabilities in non-human primates and fossil taxa has been challenging. We present a kinematic model of thumb-index precision grip and manipulative movement based on bony hand morphology in a broad sample of extant primates and fossil hominins. The model reveals that both joint mobility and digit proportions (scaled to hand size) are critical for determining precision grip and manipulation potential, but that having either a long thumb or great joint mobility alone does not necessarily yield high precision manipulation. The results suggest even the oldest available fossil hominins may have shared comparable precision grip manipulation with modern humans. In particular, the predicted human-like precision manipulation of Australopithecus afarensis, approximately one million years before the first stone tools, supports controversial archaeological evidence of tool-use in this taxon.

  18. Analysis of distribution of critical current of bent-damaged Bi2223 composite tape

    Energy Technology Data Exchange (ETDEWEB)

    Ochiai, S; Okuda, H; Hojo, M [Graduate School of Engineering, Kyoto University, Yoshida, Sakyo-ku, Kyoto 606- 8501 (Japan); Sugano, M [Graduate School of Engineering, Kyoto University, Kyoto-Daigaku Katsura, Nishikyo-ku, Kyoto 615-8530 (Japan); Osamura, K [Research Institute for Applied Sciences, Sakyo-ku, Kyoto 606-8202 (Japan); Kuroda, T; Kumakura, H; Kitaguchi, H; Itoh, K; Wada, H, E-mail: shojiro.ochiai@materials.mbox.media.kyoto-u.ac.jp [National Institute for Materials Science, 1-2-1, Sengen, Tsukuba, Ibaraki 305-0047 (Japan)

    2011-10-29

    Distributions of critical current of damaged Bi2223 tape specimens bent by 0.6, 0.8 and 1.0% were investigated analytically with a modelling approach based on the correlation of damage evolution to distribution of critical current. It was revealed that the distribution of critical current is described by three parameter Weibull distribution function through the distribution of the tensile damage strain of Bi2223 filaments that determines the damage front in bent-composite tape. Also it was shown that the measured distribution of critical current values can be reproduced successfully by a Monte Carlo simulation using the distributions of tensile damage strain of filaments and original critical current.

  19. Alcohol sensor based on u-bent hetero-structured fiber optic

    Science.gov (United States)

    Patrialova, Sefi N.; Hatta, Agus M.; Sekartedjo, Sekartedjo

    2016-11-01

    A sensor based on a fiber optic hetero-structure to determine the concentration of alcohol has been proposed. The structure of the sensing probe in this research is a singlemode-multimode-singlemode (SMS) which bent into Ushaped and soon called as SMS u-bent. The SMS structure was chosen to get a higher sensitivity. This research utilizes the principle of multimode interference and evanescent field by modifying the cladding with various alcohol concentration. Testing of the sensor's performance has been done by measuring the sensor's power output response to the length of the SMS fiber optic, bending diameter, and alcohol concentration. Based on the experiment result, the ubent SMS fiber optic with 50 mm bending diameter and 63 mm MMF lenght has the highest sensitivity, 3.87 dB/% and the minimum resolution, 0.26 x 10-3 %.

  20. A continuum model of piezoelectric potential generated in a bent ZnO nanorod

    Energy Technology Data Exchange (ETDEWEB)

    Shao, Z Z; Wen, L Y; Wu, D M [Suzhou Institute of Nano-Tech and Nano-Bionics, Chinese Academy of Sciences, Suzhou 215125 (China); Wang, X F; Zhang, X A; Chang, S L, E-mail: zzshao2009@gmail.co [Center of Materials Science, College of Science, National University of Defense Technology, Changsha 410073 (China)

    2010-06-23

    A continuum model of piezoelectric potential generated in a bent ZnO nanorod cantilever is presented by means of the first piezoelectric effect approximation. The analytical solution of the model shows that the piezoelectric potential in the nanorod is proportional to the lateral force but is independent along the longitudinal direction. The electric potential in the tensile area and that in the compressive area are antisymmetric in the cross section of the nanorod, which makes the nanorod a 'parallel plate capacitor' for piezoelectric nanodevices, such as a nanogenerator. The magnitude of piezoelectric potential for a ZnO nanorod of 50 nm diameter and 600 nm length bent by a 80 nN lateral force is about 0.27 V, which is in good agreement with the finite element method calculation.

  1. Long, elliptically bent, active X-ray mirrors with slope errors <200 nrad.

    Science.gov (United States)

    Nistea, Ioana T; Alcock, Simon G; Kristiansen, Paw; Young, Adam

    2017-05-01

    Actively bent X-ray mirrors are important components of many synchrotron and X-ray free-electron laser beamlines. A high-quality optical surface and good bending performance are essential to ensure that the X-ray beam is accurately focused. Two elliptically bent X-ray mirror systems from FMB Oxford were characterized in the optical metrology laboratory at Diamond Light Source. A comparison of Diamond-NOM slope profilometry and finite-element analysis is presented to investigate how the 900 mm-long mirrors sag under gravity, and how this deformation can be adequately compensated using a single, spring-loaded compensator. It is shown that two independent mechanical actuators can accurately bend the trapezoidal substrates to a range of elliptical profiles. State-of-the-art residual slope errors of stability over 24 h (ΔR/R = 0.07% r.m.s.) provide reliable beamline performance.

  2. Improving the energy resolution of bent crystal X-ray spectrometers with position-sensitive detectors.

    Science.gov (United States)

    Honkanen, Ari Pekka; Verbeni, Roberto; Simonelli, Laura; Moretti Sala, Marco; Al-Zein, Ali; Krisch, Michael; Monaco, Giulio; Huotari, Simo

    2014-07-01

    Wavelength-dispersive high-resolution X-ray spectrometers often employ elastically bent crystals for the wavelength analysis. In a preceding paper [Honkanen et al. (2014). J. Synchrotron Rad. 21, 104-110] a theory for quantifying the internal stress of a macroscopically large spherically curved analyser crystal was presented. Here the theory is applied to compensate for the corresponding decrease of the energy resolution. The technique is demonstrated with a Johann-type spectrometer using a spherically bent Si(660) analyser in near-backscattering geometry, where an improvement in the energy resolution from 1.0 eV down to 0.5 eV at 9.7 keV incident photon energy was observed.

  3. CMS Pixel Telescope Addition to T-980 Bent Crystal Collimation Experiment at the Tevatron

    CERN Document Server

    Rivera, Ryan; Johnson, Todd; Kwan, Simon; Lundberg, Carl; Still, Dean; Prosser, Alan; Uplegger, Lorenzo; Zagel, Jim; Zvodaya, Viktoriya

    2012-01-01

    An enhancement to the T-980 bent crystal collimation experiment at the Tevatron has been completed. The enhancement was the installation of a pixel telescope inside the vacuum-sealed beam pipe of the Tevatron. The telescope is comprised of six CMS PSI46 pixel plaquettes, arranged as three stations of horizontal and vertical planes, with the CAPTAN system for data acquisition and control. The purpose of the pixel telescope is to measure beam profiles produced by bent crystals under various conditions. The telescope electronics inside the beam pipe initially were not adequately shielded from the image current of the passing beams. A new shielding approach was devised and installed, which resolved the problem. The noise issues encountered and the mitigating techniques are presented herein, as well as some preliminary results from the telescope.

  4. Estimation of the optical loss in bent-waveguide superluminescent diodes by an analytical method

    Science.gov (United States)

    Qi, An; Peng, Jin; Zhanguo, Wang

    2015-06-01

    The optical loss in the bent region is one of the key features for bent-waveguide superluminescent diodes that affects the device performance greatly under some conditions. For the purpose of device fabrication and optimization, it will be helpful if this bend loss can be estimated. In this letter, we have derived an analytical formula which can be used to get the bend-loss coefficient by fitting the P-I curves of the devices. It is proved that the formula is successful in estimating the loss coefficients from the P-I curves simulated from a complicated quantum-dot device model. We expect this method could also be valid in estimating bend losses of actual devices. Project supported by the National Natural Science Foundation of China (Nos. 61274072, 60976057).

  5. The High-Redshift Clusters Occupied by Bent Radio AGN (COBRA) Survey

    CERN Document Server

    Paterno-Mahler, R; Ashby, M L N; Brodwin, M; Wing, J D; Anand, G; Decker, B; Golden-Marx, E

    2016-01-01

    We present 238 high-redshift galaxy cluster candidates based on galaxy overdensities in the Spitzer/IRAC imaging of the fields surrounding 646 bent, double-lobed radio sources drawn from the Clusters Occupied by Bent Radio AGN (COBRA) Survey. The COBRA sources were chosen as objects in the VLA FIRST survey that lack optical counterparts in the Sloan Digital Sky Survey (SDSS) to a limit of $m_r=22$, making them likely to lie at high redshift. This is confirmed by our observations: the redshift distribution of COBRA sources with estimated redshifts peaks near $z=1$, and extends out to $z\\approx3$. Cluster candidates were identified by comparing our sources to a background field and searching for overdensities. Forty-one of these sources are quasars with known spectroscopic redshifts, which may be tracers of some of the most distant clusters known.

  6. CMS Pixel Telescope Addition to T-980 Bent Crystal Collimation Experiment at the Tevatron

    Energy Technology Data Exchange (ETDEWEB)

    Rivera, Ryan; Annala, Jerry; Johnson, Todd; Kwan, Simon; Lundberg, Carl; Still, Dean; Prosser, Alan; Uplegger, Lorenzo; Zagel, Jim; Zvodaya, Viktoriya; /Fermilab

    2011-09-14

    An enhancement to the T-980 bent crystal collimation experiment at the Tevatron has been completed. The enhancement was the installation of a pixel telescope inside the vacuum-sealed beam pipe of the Tevatron. The telescope is comprised of six CMS PSI46 pixel plaquettes, arranged as three stations of horizontal and vertical planes, with the CAPTAN system for data acquisition and control. The purpose of the pixel telescope is to measure beam profiles produced by bent crystals under various conditions. The telescope electronics inside the beam pipe initially were not adequately shielded from the image current of the passing beams. A new shielding approach was devised and installed, which resolved the problem. The noise issues encountered and the mitigating techniques are presented herein, as well as some preliminary results from the telescope.

  7. Proton and Pb ion beam extraction experiments with bent crystals at the CERN-SPS

    CERN Document Server

    Elsener, K; Klem, J T; CERN. Geneva. SPS and LEP Division

    1997-01-01

    Extraction of particle beams from the CERN-SPS using bent silicon crystals is described. A summary of the early results is given. Emphasis is on the recent experiments, in particular on the energy dependence of proton extraction at 14, 120 and 270 GeV. 'U-shaped' crystals of different thickness and with a different miscut angle have been compared at 120 GeV. Non-linear excitation of the beam was used in one experiment, with the aim to achieve larger impact parameters - the results show a particular behaviour in the tails of the beam. Finally, the first experimental result on extraction of a 22 TeV fully stripped Pb ion beam with a bent crystal is also described.

  8. Investigation of sport rock climbers’ handgrip strength

    Directory of Open Access Journals (Sweden)

    Burak Gürer

    2015-10-01

    Full Text Available This study aims to investigate handgrip strengths of elite sportsmen who are involved in sport rock climbing. Study group was composed of 144 sportsmen from 22 countries who participated in Petzl Roc Trip sport rock climbing festival held in Turkey between 14 and 19 October 2014. Data were collected by using Takei Grip-D brand hand dynamometer. The data collected were analyzed and interpreted by statistical package programme (SPSS 16.0. Results show meaningful differences between sportsmen’s right handgrip strength and left handgrip strength. Sportsmen’s right handgrip strength was found to be higher. Results differed based on gender as well. Left and right handgrip strength of males was found to be higher to those of females. No significant relationships were detected based on nationality, age, history of climbing and period of experience in climbing. Relationships were observed between Turkish male and female climbers’ right and left handgrip strengths. As a result, it can be claimed that right hand is used more often in sport rock climbing compared to the left hand. It is also believed that fingers and technique are crucial in sport rock climbing. Practices to develop finger strength and techniques are suggested.

  9. A relationship between the nonexistence of generalized bent functions and class groups

    Institute of Scientific and Technical Information of China (English)

    2010-01-01

    A new result on the nonexistence of generalized bent functions is presented by using properties of the decomposition law of primes in cyclotomic fields and properties of solutions of some Diophantine equations. At the same time,a method is given which can be used to simplify the known results. Then we give the bounds and the meaning in algebraic number theory of the parameters in our results.

  10. Observation of nuclear dechanneling length reduction for high energy protons in a short bent crystal

    Directory of Open Access Journals (Sweden)

    W. Scandale

    2015-04-01

    Full Text Available Deflection of 400 GeV/c protons by a short bent silicon crystal was studied at the CERN SPS. It was shown that the dechanneling probability increases while the dechanneling length decreases with an increase of incident angles of particles relative to the crystal planes. The observation of the dechanneling length reduction provides evidence of the particle population increase at the top levels of transverse energies in the potential well of the planar channels.

  11. Liquid-crystalline hybrid materials based on [60]fullerene and bent-core structures.

    Science.gov (United States)

    Vergara, Jorge; Barberá, Joaquín; Serrano, José Luis; Ros, M Blanca; Sebastián, Nerea; de la Fuente, Rosario; López, David O; Fernández, Gustavo; Sánchez, Luis; Martín, Nazario

    2011-12-23

    What a core-ker! By the appropriate combination of promesogenic bent-core structures and the C(60)  unit, lamellar polar liquid-crystal phases were induced. The supramolecular organization of the functional fullerene-based assemblies, the temperature range of the soft phase, the stabilization of the mesophase-like order at room temperature, and the molecular switching under an electric field can be tuned, depending on the molecular structure.

  12. First results on proton extraction from the CERN-SPS with a bent crystal

    Science.gov (United States)

    Akbari, H.; Altuna, X.; Bardin, S.; Bellazzini, R.; Biryukov, V.; Brez, A.; Bussa, M. P.; Busso, L.; Calcaterra, A.; Carboni, G.; Costantini, F.; de Sangro, R.; Elsener, K.; Ferioli, F.; Ferrari, A.; Ferri, G. P.; Ferroni, F.; Fidecaro, G.; Freund, A.; Guinand, R.; Gyr, M.; Herr, W.; Hilaire, A.; Jensen, B. N.; Klem, J.; Lanceri, L.; Maier, K.; Massai, M. M.; Mertens, V.; Møller, S. P.; Morganti, S.; Palamara, O.; Peraire, S.; Petrera, S.; Placidi, M.; Santacesaria, R.; Scandale, W.; Schmidt, R.; Taratin, A. M.; Tosello, F.; Uggerhøj, E.; Vettermann, B.; Vita, P. F.; Vuagnin, G.; Weisse, E.; Weisz, S.

    1993-09-01

    The feasibility of extracting protons from the halo of a high energy beam by means of a bent silicon crystal has been investigated. Protons diffusing from a GeV beam circulating in the SPS at CERN have been extracted at an angle of 8.5 mrad. Efficiencies of abour 10 percent, orders of magnitude higher than the values achieved previously, have been measured. The present results are promising in view of beam extraction from future multi-TeV proton accelerators.

  13. Extraction of time and frequency features from grip force rates during dexterous manipulation.

    Science.gov (United States)

    Mojtahedi, Keivan; Fu, Qiushi; Santello, Marco

    2015-05-01

    The time course of grip force from object contact to onset of manipulation has been extensively studied to gain insight into the underlying control mechanisms. Of particular interest to the motor neuroscience and clinical communities is the phenomenon of bell-shaped grip force rate (GFR) that has been interpreted as indicative of feedforward force control. However, this feature has not been assessed quantitatively. Furthermore, the time course of grip force may contain additional features that could provide insight into sensorimotor control processes. In this study, we addressed these questions by validating and applying two computational approaches to extract features from GFR in humans: 1) fitting a Gaussian function to GFR and quantifying the goodness of the fit [root-mean-square error, (RMSE)]; and 2) continuous wavelet transform (CWT), where we assessed the correlation of the GFR signal with a Mexican Hat function. Experiment 1 consisted of a classic pseudorandomized presentation of object mass (light or heavy), where grip forces developed to lift a mass heavier than expected are known to exhibit corrective responses. For Experiment 2, we applied our two techniques to analyze grip force exerted for manipulating an inverted T-shaped object whose center of mass was changed across blocks of consecutive trials. For both experiments, subjects were asked to grasp the object at either predetermined or self-selected grasp locations ("constrained" and "unconstrained" task, respectively). Experiment 1 successfully validated the use of RMSE and CWT as they correctly distinguished trials with versus without force corrective responses. RMSE and CWT also revealed that grip force is characterized by more feedback-driven corrections when grasping at self-selected contact points. Future work will examine the application of our analytical approaches to a broader range of tasks, e.g., assessment of recovery of sensorimotor function following clinical intervention, interlimb

  14. Maximal intermittent handgrip strategy: design and evaluation of an exercise protocol and a grip tool.

    Science.gov (United States)

    Bentley, Danielle Christine; Thomas, Scott Gordon

    2016-01-01

    Handgrip (HG) exercise has been prescribed as a lifestyle intervention to successfully reduce resting blood pressure (BP) among heterogeneous groups of participants. Current HG protocols have limited accessibility due to complicated exercise prescriptions and sophisticated required equipment. Therefore, this research describes the design and evaluation of the maximal intermittent (MINT) HG exercise strategy, consisting of both a novel exercise protocol (32×5 seconds maximal grip squeezes separated by 5 seconds of rest between sets) and an original grip tool. This research was a multistep progressive design that included 51 postmenopausal women as participants in three separate research studies. Part 1 of this research focuses on the MINT exercise protocol. A literature-informed rationale for the design of the protocol is described. This includes exercise intensity, work-to-rest ratio, and total exercise duration with reference to the unique physiology (mechanoreflex and metaboreflex) of postmenopausal women. Subsequent experimental analyses of acute responses to the MINT protocol revealed that women produced 50% of their maximum grip force with moderate cardiovascular responses (increases of systolic BP: 41.6 mmHg, diastolic BP: 20.1 mmHg, heart rate: 35.1 bpm) that remained far below the thresholds of concern identified by the American College of Sports Medicine. Part 2 of this research describes the creation of a novel grip tool, beginning with a mixed-methods assessment of participant opinions regarding two distinct in-laboratory grip tools, leading to the creation of four prototype MINT tools. Structured focus groups revealed a strong preference for MINT prototype 1 for all tool design features, including color, shape, size, and foam grip. Collectively, the result of this multistep research is a novel HG exercise strategy with enhanced accessibility by being easy to understand and simple to execute. The long-term training effectiveness of MINT as an exercise

  15. Determining the diffraction properties of a cylindrically bent KAP(001) crystal from 1 to 5 keV

    Energy Technology Data Exchange (ETDEWEB)

    Haugh, Michael [National Security Technologies, LLC. (NSTec), Mercury, NV (United States); Lee, Joshua [National Security Technologies, LLC. (NSTec), Mercury, NV (United States); Jacoby, Kenneth [National Security Technologies, LLC. (NSTec), Mercury, NV (United States); Christensen, C. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Loisel, G. [National Security Technologies, LLC. (NSTec), Mercury, NV (United States), Livermore Operations

    2015-08-31

    Various crystals are used for the dispersive component of X-ray spectrometers. The crystals are usually bent to meet the desired measurement needs, such as focusing. The bending can change the crystal diffraction properties, thus altering the spectrometer throughput and resolving power. This work concerns measuring the diffraction properties of a potassium acid phthalate (001) [KAP(001)] crystal bent into a circular cylinder segment. The measurement methods using a diode source and a synchrotron source are described. The multi-lamellar model for calculating the diffraction properties of a bent crystal is described. The measurement results are compared to the multi-lamellar model and show qualitative agreement. The measurements show how to make the multi-lamellar calculations a useful estimate. A method is given to make useful estimates of the diffraction properties of the KAP(001) crystal bent into a circular cylinder segment.

  16. Stig Sundell at the bent crystal X-ray spectrometer for the X-ray shift experiment.

    CERN Multimedia

    1976-01-01

    The bent crystal X-ray spectrometer is being used to measure small shifts in the frequencies of X-rays emitted from the lower electron energy levels, in order to learn about the size of the nuclei concerned

  17. Extragalactic Jets as Probes of Distant Clusters of Galaxies and the Clusters Occupied by Bent Radio AGN (COBRA) Survey

    CERN Document Server

    Blanton, Elizabeth L; Wing, Joshua D; Ashby, M L N; Golden-Marx, Emmet; Brodwin, Mark; Douglass, E M; Randall, Scott W; Clarke, T E

    2014-01-01

    We are conducting a large survey of distant clusters of galaxies using radio sources with bent jets and lobes as tracers. These radio sources are driven by AGN and achieve their bent morphologies through interaction with the surrounding gas found in clusters of galaxies. Based on low-redshift studies, these types of sources can be used to identify clusters very efficiently. We present initial results from our survey of 653 bent-double radio sources with optical hosts too faint to appear in the SDSS. The sample was observed in the infrared with Spitzer, and it has revealed $\\sim$200 distant clusters or proto-clusters in the redshift range $z\\sim0.7 - 3.0$. The sample of bent-doubles contains both quasars and radio galaxies enabling us to study both radiative and kinetic mode feedback in cluster and group environments at a wide range of redshifts.

  18. The signs B and B-bent in Israeli sign language according to the theory of Phonology as Human Behavior.

    Science.gov (United States)

    Fuks, Orit; Tobin, Yishai

    2008-01-01

    The purpose of the present research is to examine which of the two factors: (1) the iconic-semiotic factor; or (2) the human-phonetic factor is more relevant in explaining the appearance and distribution of the hand shape B-bent in Israeli Sign Language (ISL). The B-bent shape has been the subject of much attention in sign language research revolving around the question of its status as a phoneme. The arguments supporting the phonemic status of the B-bent hand shape have been primarily based on the semiotic opposition between the hand shape B and the hand shape B-bent. It has been claimed that in Italian Sign Language the hand shape B is perceptually distinct from the hand shape B-bent, i.e. in opposition to the general, neutral, unmarked meaning of the hand shape B, the iconic hand shape B-bent has a more narrow, specific and marked meaning: DELIMIT. The B-bent hand shape appears in spatial-temporal signs such as "a little before, ahead, postpone or behind". In these signs the iconic structure of the hand shape B-bent is utilized to mark borders in space and time. The arguments opposing the perceptual/phonemic distinction between these hand shapes is based on the human-phonetic factor, i.e. the need to reduce the effort on the part of the wrist joints in specific phonetic environments. We performed a quantitative and qualitative content analysis of the distribution of the basic units of 560 lexical signs taken from a stratified random sample from the ISL dictionary. The results were analyzed in the framework of the sign-oriented linguistic theory of the Columbia School including the theory of Phonology as Human Behavior. Our data revealed that the B-bent hand shape--as all the "building blocks" of the ISL--is a morpho-phonemic unit. We found that there is not only a phonemic distinction between hand shape B and hand shape B-bent in ISL (based on minimal pairs), but there is also a perceptual distinction between them. The qualitative analysis shows that the

  19. Channeling of fast ions through the bent carbon nanotubes: The extended two-fluid hydrodynamic model

    Science.gov (United States)

    Lazar, Karbunar; Duško, Borka; Ivan, Radović; Zoran, L. Mišković

    2016-04-01

    We investigate the interactions of charged particles with straight and bent single-walled carbon nanotubes (SWNTs) under channeling conditions in the presence of dynamic polarization of the valence electrons in carbon. This polarization is described by a cylindrical, two-fluid hydrodynamic model with the parameters taken from the recent modelling of several independent experiments on electron energy loss spectroscopy of carbon nano-structures. We use the hydrodynamic model to calculate the image potential for protons moving through four types of SWNTs at a speed of 3 atomic units. The image potential is then combined with the Doyle-Turner atomic potential to obtain the total potential in the bent carbon nanotubes. Using that potential, we also compute the spatial and angular distributions of protons channeled through the bent carbon nanotubes, and compare the results with the distributions obtained without taking into account the image potential. Project supported by the Funds from the Ministry of Education, Science and Technological Development of the Republic of Serbia (Grant No. 45005). Z. L. Mišković thanks the Natural Sciences and Engineering Research Council of Canada for Finacial Support.

  20. A bent Laue-Laue monochromator for a synchrotron-based computed tomography system

    CERN Document Server

    Ren, B; Chapman, L D; Ivanov, I; Wu, X Y; Zhong, Z; Huang, X

    1999-01-01

    We designed and tested a two-crystal bent Laue-Laue monochromator for wide, fan-shaped synchrotron X-ray beams for the program multiple energy computed tomography (MECT) at the National Synchrotron Light Source (NSLS). MECT employs monochromatic X-ray beams from the NSLS's X17B superconducting wiggler beamline for computed tomography (CT) with an improved image quality. MECT uses a fixed horizontal fan-shaped beam with the subject's apparatus rotating around a vertical axis. The new monochromator uses two Czochralski-grown Si crystals, 0.7 and 1.4 mm thick, respectively, and with thick ribs on their upper and lower ends. The crystals are bent cylindrically, with the axis of the cylinder parallel to the fan beam, using 4-rod benders with two fixed rods and two movable ones. The bent-crystal feature of the monochromator resolved the difficulties we had had with the flat Laue-Laue design previously used in MECT, which included (a) inadequate beam intensity, (b) excessive fluctuations in beam intensity, and (c) i...

  1. HIV-1 DIS stem loop forms an obligatory bent kissing intermediate in the dimerization pathway.

    Science.gov (United States)

    Mundigala, Hansini; Michaux, Jonathan B; Feig, Andrew L; Ennifar, Eric; Rueda, David

    2014-06-01

    The HIV-1 dimerization initiation sequence (DIS) is a conserved palindrome in the apical loop of a conserved hairpin motif in the 5'-untranslated region of its RNA genome. DIS hairpin plays an important role in genome dimerization by forming a 'kissing complex' between two complementary hairpins. Understanding the kinetics of this interaction is key to exploiting DIS as a possible human immunodeficiency virus (HIV) drug target. Here, we present a single-molecule Förster resonance energy transfer (smFRET) study of the dimerization reaction kinetics. Our data show the real-time formation and dissociation dynamics of individual kissing complexes, as well as the formation of the mature extended duplex complex that is ultimately required for virion packaging. Interestingly, the single-molecule trajectories reveal the presence of a previously unobserved bent intermediate required for extended duplex formation. The universally conserved A272 is essential for the formation of this intermediate, which is stabilized by Mg(2+), but not by K(+) cations. We propose a 3D model of a possible bent intermediate and a minimal dimerization pathway consisting of three steps with two obligatory intermediates (kissing complex and bent intermediate) and driven by Mg(2+) ions. © The Author(s) 2014. Published by Oxford University Press on behalf of Nucleic Acids Research.

  2. Corticomuscular coherence during hand gripping with DBS and medication in PD patients

    DEFF Research Database (Denmark)

    Sridharan, Kousik Sarathy; Højlund, Andreas; Johnsen, Erik Lisbjerg

    (MEG) from six PD patients performing hand gripping during DBS ON and medicated (levodopa, MED ON) conditions and from ten age-matched healthy controls. Participants performed isotonic contractions (hand gripping) with their right hand, and electromyography (EMG) was recorded from the extensor...... digitorum communis muscle with a belly-tendon montage. We calculated the mean-squared coherence between MEG and the rectified EMG signals. For each group and condition, we selected the maximum CMC value in the beta range (13-30 Hz) within the average of an a priori selection of nine left sensorimotor...

  3. Wear and Grip Loss Evaluation of High Chromium Welding Deposits Applied on Sugar Cane Rolls1

    OpenAIRE

    Diaz Millan, Sebastian; Rugbeño S.A.S; Aguilar Castro, Yesid; Escuela de Ingeniería de Materiales, Universidad del Valle, Cali, Colombia; Casanova García, Gonzalo Fernando; Escuela de Ingeniería Mecánica,Universidad del Valle, Cali, Colombia

    2015-01-01

    Wear on sugar cane rolls is an expensive maintenance problem for the sugar cane industry. Wear produces loss of sucrose extraction and loss of grip of the roll on the bagasse. This paper presents the evaluation of wear and loss of grip of hypoeutectic and hypereutectic high chromium welding deposits applied on ASTM A-36 steel and gray cast iron. A modified ASTM G-65 standard test was used. Wear was produced by the abrasive action of wet bagasse with three levels of mineral extraneous matter. ...

  4. The determination of the operating range of a twin-grip control yoke through biomechanical means

    Science.gov (United States)

    Gaertner, K. P.

    1978-01-01

    A twin-grip control yoke was designed as an ergonomic case study that allows dual axis control inputs, both axes being rotational. Inputs are effected by rotating the grips. How the handles were designed with respect to their shape and size and how the angular range of the control yoke in both rotational axes was evaluated. The control yoke which requires two-hand operation was tested to determine its operating range. The intention of this investigation was to find out the optimal form of the control yoke and the maximum permissible range in both rotating axes. In these experiments controls had no spring resistance.

  5. The cost-effectiveness of grip on challenging behaviour: an economic evaluation of a care programme for managing challenging behaviour

    NARCIS (Netherlands)

    Zwijsen, S.A.; Bosmans, J.E.; Gerritsen, D.L.; Pot, A.M.; Hertogh, C.M.; Smalbrugge, M.

    2016-01-01

    OBJECTIVE: The objective of the study was to evaluate the cost-effectiveness of implementing the Grip on Challenging Behaviour care programme (GRIP) on dementia special care units in comparison with usual care. METHODS: A stepped wedge design was used. Challenging behaviour and quality of life were

  6. Strength Training

    Science.gov (United States)

    ... strengthens your heart and lungs. When you strength train with weights, you're using your muscles to ... see there are lots of different ways to train with weights. Try a few good basic routines ...

  7. Strength Training

    Science.gov (United States)

    ... en español Entrenamiento de la fuerza muscular Strength training is a vital part of a balanced exercise routine that includes aerobic activity and flexibility exercises. Regular aerobic exercise, such as running or ...

  8. Subcutaneous immunoglobulin preserves muscle strength in chronic inflammatory demyelinating polyneuropathy

    DEFF Research Database (Denmark)

    Markvardsen, Lars Høj; Harbo, Thomas; Sindrup, Søren Hein

    2014-01-01

    BACKGROUND AND PURPOSE: Subcutaneous immunoglobulin (SCIG) is superior to placebo treatment for maintenance of muscle strength during 12 weeks in patients with chronic inflammatory demyelinating polyneuropathy (CIDP). The present study evaluated whether SCIG preserves muscle strength for 1 year...... evaluated after 3, 6 and 12 months. Primary end-points were changes in muscle strength evaluated by isokinetic dynamometry in four affected muscle groups and a composite score of muscle performance and function tests, including Medical Research Council (MRC) score, grip strength, 40-m walking test (40-MWT...... remained unchanged. CONCLUSION: SCIG preserves muscle strength and functional ability in patients with CIDP who previously responded to IVIG. SCIG should be considered as an alternative in long-term treatment of CIDP patients....

  9. Weight-specific anticipatory coding of grip force in human dorsal premotor cortex

    DEFF Research Database (Denmark)

    van Nuenen, Bart F L; Kuhtz-Buschbeck, Johann; Schulz, Christian

    2012-01-01

    ). An additional pre-cue (S1) correctly predicted the weight in 75% of the trials. Participants were asked to use this prior information to prepare for the lift. In the sham condition, grip force showed a consistent undershoot, if the S1 incorrectly prompted the preparation of a light lift. Likewise, an S1...

  10. Eyes, Grip and Gesture as Objective Indicators of Intentions and Attention

    DEFF Research Database (Denmark)

    Mortensen, Ditte Hvas

    This poster abstract presents the first part of a study concerning the use of information about gaze, grip and gesture to create non-command interaction. The experiment reported here seeks to establish the occurrence of patterns in nonverbal communication,  which may be used in an activity aware...

  11. Facilitation of corticospinal tract excitability by transcranial direct current stimulation combined with voluntary grip exercise.

    Science.gov (United States)

    Kim, Gi-Wook; Ko, Myoung-Hwan

    2013-08-26

    Previous studies have established that transcranial direct current stimulation (tDCS) is a powerful technique for the deliberate manipulation of the activity of human cerebral cortex. Moreover, it has also been shown that the non-exhausted voluntary motor exercise increases the excitability of corticospinal tract. We conducted this study to define the facilitation effect following anodal tDCS combined with the voluntary grip exercise as compared with single use of tDCS or voluntary grip exercise. Our result showed that the combination of anodal tDCS with voluntary grip exercise produced a 2-fold increase in the amplitude of MEP as compared with single use of anodal tDCS or voluntary grip exercise. In conclusion, our result could indicate that the treatment outcomes of brain and neurorehabilitation using tDCS would be better when tDCS is combined with the appropriate method of voluntary exercise as compared with single use of tDCS. Copyright © 2013 Elsevier Ireland Ltd. All rights reserved.

  12. Grip Force Control Is Dependent on Task Constraints in Children with and without Developmental Coordination Disorder

    Science.gov (United States)

    Law, Sui-Heung; Lo, Sing Kai; Chow, Susanna; Cheing, Gladys L.Y.

    2011-01-01

    Excessive grip force (GF) is often found in children with developmental coordination disorder (DCD). However, their GF control may vary when task constraints are imposed upon their motor performance. This study aimed to investigate how their GF control changes in response to task demands, and to examine their tactile sensitivity. Twenty-one…

  13. The effect of precision and power grips on activations in human auditory cortex

    Directory of Open Access Journals (Sweden)

    Patrik Alexander Wikman

    2015-10-01

    Full Text Available The neuroanatomical pathways interconnecting auditory and motor cortices play a key role in current models of human auditory cortex (AC. Evidently, auditory-motor interaction is important in speech and music production, but the significance of these cortical pathways in other auditory processing is not well known. We investigated the general effects of motor responding on AC activations to sounds during auditory and visual tasks. During all task blocks, subjects detected targets in the designated modality, reported the relative number of targets at the end of the block, and ignored the stimuli presented in the opposite modality. In each block, they were also instructed to respond to targets either using a precision grip, power grip, or to give no overt target responses. We found that motor responding strongly modulated AC activations. First, during both visual and auditory tasks, activations in widespread regions of AC decreased when subjects made precision and power grip responses to targets. Second, activations in AC were modulated by grip type during the auditory but not during the visual task. Further, the motor effects were distinct from the strong attention-related modulations in AC. These results are consistent with the idea that operations in AC are shaped by its connections with motor cortical regions.

  14. Precision grip in congenital and acquired hemiparesis: similarities in impairments and implications for neurorehabilitation - review

    Directory of Open Access Journals (Sweden)

    Yannick eBleyenheuft

    2014-06-01

    Full Text Available Background: Patients with congenital and acquired hemiparesis incur long-term functional deficits, among which the loss of prehension that may impact their functional independence. Identifying, understanding and comparing the underlying mechanisms of prehension impairments represent an opportunity to better adapt neurorehabilitationObjective: The present review aims to provide a better understanding of precision grip deficits in congenital and acquired hemiparesis and to determine whether the severity and type of fine motor control impairments depend on whether or not the lesions are congenital or acquired in adulthood. Methods: Using combinations of the following key words: fingertip force, grip force, precision grip, cerebral palsy, stroke, pubmed and Scopus databases were used to search studies from 1984 to 2013. Results: Individuals with both congenital and acquired hemiparesis were able to some extent to use anticipatory motor control in precision grip tasks, even if this control was impaired in the paretic hand. In both congenital or acquired hemiparesis, the ability to plan efficient anticipatory motor control when the less-affected hand is used provides a possibility to remediate impairments in anticipatory motor control of the paretic hand. Conclusion: Surprisingly we observed very few differences between the results of studies in children with congenital hemiplegia and stroke patients. We suggest that the underlying specific strategies of neurorehabilitation developed for each one could benefit the other.

  15. Getting a grip on numbers : Numerical magnitude priming in object grasping

    NARCIS (Netherlands)

    Lindemann, Oliver; Abolafia, Juan A.; Girardi, Giovanna; Bekkering, Harold

    2007-01-01

    To investigate the functional connection between numerical cognition and action planning, the authors required participants to perform different grasping responses depending on the parity status of Arabic digits. The results show that precision grip actions were initiated faster in response to small

  16. Frimand Needle Holder Reduces Suturing Time and Surgical Stress When Suturing in Palm Grip.

    Science.gov (United States)

    Frimand Rönnow, Carl-Fredrik; Jeppsson, Bengt; Thorlacius, Henrik

    2016-06-01

    Purpose The Frimand needle holder (FNH) was developed to facilitate palm grip suturing. In the present study, we wanted to examine the impact of the FNH compared with a conventional Hegar-styled needle holder (HSNH) on suture time and surgical stress. Methods Thirty-two surgeons were enrolled and they performed sets of 3 continuous sutures on a polyurethane pad with premarked insert and exit points and the time for suturing was measured. Surgical stress was quantified by having the surgeons to perform 10 release maneuvers with the FNH and the HSNH on a needle attached to a scale. The scale sent 5 values per second to a computer. The first measurement of each series was regarded as the starting weight and all subsequent measurements were either regarded as neutral, pressure or traction. The sum of these measurements represented total surgical stress. Results We found that all surgeons reduced their median suturing time by 16% when using FNH for palm grip suturing with no difference between junior and senior surgeons. Moreover, it was observed that FNH decreased median surgical stress by 62% for all surgeons performing palm grip suturing compared with a conventional HSNH. Conclusion We conclude that the FNH reduces suture time and surgical stress compared with HSNH when performing palm grip suturing. These findings warrant studies in surgical patients in order to evaluate the potential clinical impact of FNH.

  17. First flight of the Gamma-Ray Imager/Polarimeter for Solar flares (GRIPS) instrument

    CERN Document Server

    Duncan, Nicole; Shih, A Y; Hurford, G J; Bain, H M; Amman, M; Mochizuki, B A; Hoberman, J; Olson, J; Maruca, B A; Godbole, N M; Smith, D M; Sample, J; Kelley, N A; Zoglauer, A; Caspi, A; Kaufmann, P; Boggs, S; Lin, R P

    2016-01-01

    The Gamma-Ray Imager/Polarimeter for Solar flares (GRIPS) is a balloon-borne telescope designed to study solar-flare particle acceleration and transport. We describe GRIPS's first Antarctic long-duration flight in Jan 2016 and report preliminary calibration and science results. Electron and ion dynamics, particle abundances and the ambient plasma conditions in solar flares can be understood by examining hard X-ray (HXR) and gamma-ray emission (20 keV to 10 MeV) with enhanced imaging, spectroscopy and polarimetry. GRIPS is specifically designed to answer questions including: What causes the spatial separation between energetic electrons producing HXRs and energetic ions producing gamma-ray lines? How anisotropic are the relativistic electrons, and why can they dominate in the corona? How do the compositions of accelerated and ambient material vary with space and time, and why? GRIPS's key technological improvements over the Reuven Ramaty High Energy Solar Spectroscopic Imager (RHESSI) include 3D position-sensi...

  18. THE ROLE OF MORPHOLOGICAL VARIABLES IN DETERMINING STRENGTH AND FLEXIBILITY IN DIFFERENT SPORTS BRANCHES IN SCHOOL OF PHYSICAL EDUCATION AND SPORTS STUDENTS

    Directory of Open Access Journals (Sweden)

    Ali ÖZKAN

    2014-07-01

    Full Text Available The purpose of the present study was to determination of the morphological variables in determining role of strength and flexibility in dıfferent sports branches in School of Physical Education and Sports sudents . A total of 71 different sports branches players ( 푋 age: 21.16±3.65 year participated in this study voluntarily. Subjects’ height, body weight, body mass index, body fat percentage and total of seven skinfold thicknesses were determined. Body fat percentage was determined by Yuhasz formula. Sit and reach test was used to determinate. Isometric dynamometer was used for the determination of knee (KS, back (BS, grip (GS and total strength (TS. Results of Pearson Product Moment correlation analysis, height was significantly correlated with right hand grip strength (r=.267, p<.01 and total strength (r= .354, p<.05. Similarly body weight was significantly positive correlated with right hand grip strength (r=.250, p<.01 and total strength (r=.542, p<.05. On the other hand, total of seven skinfol d thicknesses was significantly positive correlated with left hand grip strength (r=.286, p<.01. As a conclusion, the findings of the present study indicated that morphological variables plays important role in different sports branches in School of Physi cal Education and Sports sudents.

  19. Measurement error in grip and pinch force measurements in patients with hand injuries.

    Science.gov (United States)

    Schreuders, Ton A R; Roebroeck, Marij E; Goumans, Janine; van Nieuwenhuijzen, Johan F; Stijnen, Theo H; Stam, Henk J

    2003-09-01

    There is limited documentation of measurement error of grip and pinch force evaluation methods. The purposes of this study were (1) to determine indexes of measurement error for intraexaminer and interexaminer measurements of grip and pinch force in patients with hand injuries and (2) to investigate whether the measurement error differs between measurements of the injured and noninjured hands and between experienced and inexperienced examiners. The subjects were a consecutive sample of 33 patients with hand injuries who were seen in the Department of Rehabilitation Medicine of Erasmus MC-University Medical Center Rotterdam in the Netherlands. Repeated measurements were taken of grip and pinch force, with a short break of 2 to 3 minutes between sessions. For the grip force in 2 handle positions (distance between handles of 4.6 and 7.2 cm, respectively), tip pinch (with the index finger on top and the thumb below, with the other fingers flexed) and key pinch force (with the thumb on top and the radial side of the index finger below) data were obtained on both hands of the subjects by an experienced examiner and an inexperienced examiner. Intraclass correlation coefficients (ICCs), standard errors of measurement (SEMs), and associated smallest detectable differences (SDDs) were calculated and compared with data from previous studies. The reliability of the measurements was expressed by ICCs between .82 and .97. For grip force measurements (in the second handle position) by the experienced examiner, an SDD of 61 N was found. For tip pinch and key pinch, these values were 12 N and 11 N, respectively. For measurements by the inexperienced examiner, SDDs of 56 N for grip force and 13 N and 18 N for tip pinch and key pinch were found. Based on the SEMs and SDDs, in individual patients only relatively large differences in grip and pinch force measurements can be adequately detected between consecutive measurements. Measurement error did not differ between injured and

  20. Enhanced independence: experiences after regaining grip function in people with tetraplegia.

    Science.gov (United States)

    Wangdell, Johanna; Carlsson, Gunnel; Fridén, Jan

    2013-01-01

    To explore how surgical reconstruction of grip affects everyday life for patients with tetraplegia, with special emphasis on patients perspective of their perceived changes. Qualitative method. Eleven people (aged 22-73) with tetraplegia who had undergone surgical reconstruction to restore grip function. Qualitative interviews were conducted 7-17 months after surgery and analysed using Grounded theory. The core concept describing the participants experienced gains after grip reconstructive surgery was "enhanced independence". It was associated with changes in both practical and psychological aspects of independence. Practical aspects identified were: "perform more activities", "smoother everyday life", "renewed ability to participate in social activities", "less dependence on assistance" and "less restricted by physical environment". Psychological aspects of independence included "regained privacy", "increased manageability", "regained identity", "recapture a part of the body" and "share positive experiences with relatives and friends". Encompassing all categories was the concept "self-efficacy in hand control". It was seen as a result included in the enhanced independency core but also as an important factor for the development of all the other categories. Participants in this study experienced enhanced independence after grip reconstructive surgery and rehabilitation. The enhanced independence included both practical and physical aspects and it influenced all domains using the International Classification of Function, Disability and Health model; body function and structure, activities, participation, personal factors and environmental factors. Implications for Rehabilitation Patients with tetraplegia experience grip reconstruction as a useful intervention, an enhanced independence, related to their improved hand control. The increased hand control impacted not only physical aspects but also practical and psychological aspects. It also influenced social and

  1. The Nature of the Idealized Triple Bonds Between Principal Elements and the σ Origins of Trans-Bent Geometries-A Valence Bond Study.

    Science.gov (United States)

    Ploshnik, Elina; Danovich, David; Hiberty, Philippe C; Shaik, Sason

    2011-04-12

    We describe herein a valence bond (VB) study of 27 triply bonded molecules of the general type X≡Y, where X and Y are main element atoms/fragments from groups 13-15 in the periodic table. The following conclusions were derived from the computational data: (a) Single π-bond and double π-bond energies for the entire set correlate with the "molecular electronegativity", which is the sum of the X and Y electronegativites for X≡Y. The correlation with the molecular electronegativity establishes a simple rule of periodicity: π-bonding strength generally increases from left to right in a period and decreases down a column in the periodic table. (b) The σ frame invariably prefers trans bending, while π-bonding gets destabilized and opposes the trans distortion. In HC≡CH, the π-bonding destabilization overrides the propensity of the σ frame to distort, while in the higher row molecules, the σ frame wins out and establishes trans-bent molecules with 2(1)/2 bonds, in accord with recent experimental evidence based on solid state (29)Si NMR of the Sekiguchi compound. Thus, in the trans-bent molecules "less bonds pay more". (c) All of the π bonds show significant bonding contributions from the resonance energy due to covalent-ionic mixing. This quantity is shown to correlate linearly with the corresponding "molecular electronegativity" and to reflect the mechanism required to satisfy the equilibrium condition for the bond. The π bonds for molecules possessing high molecular electronegativity are charge-shift bonds, wherein bonding is dominated by the resonance energy of the covalent and ionic forms, rather than by either form by itself.

  2. Channeling, Volume Reection and Gamma Emission Using 14GeV Electrons in Bent Silicon Crystals

    Energy Technology Data Exchange (ETDEWEB)

    Benson, Brandon [SLAC National Accelerator Lab., Menlo Park, CA (United States)

    2015-08-14

    High energy electrons can be deflected with very tight bending radius using a bent silicon crystal. This produces gamma radiation. As these crystals can be thin, a series of bent silicon crystals with alternating direction has the potential to produce coherent gamma radiation with reasonable energy of the driving electron beam. Such an electron crystal undulator offers the prospect for higher energy radiation at lower cost than current methods. Permanent magnetic undulators like LCLS at SLAC National Accelerator Laboratory are expensive and very large (about 100 m in case of the LCLS undulator). Silicon crystals are inexpensive and compact when compared to the large magnetic undulators. Additionally, such a high energy coherent light source could be used for probing through materials currently impenetrable by x-rays. In this work we present the experimental data and analysis of experiment T523 conducted at SLAC National Accelerator Laboratory. We collected the spectrum of gamma ray emission from 14 GeV electrons on a bent silicon crystal counting single photons. We also investigated the dynamics of electron motion in the crystal i.e. processes of channeling and volume reflection at 14 GeV, extending and building off previous work. Our single photon spectrum for the amorphous crystal orientation is consistent with bremsstrahlung radiation and the volume reflection crystal orientation shows a trend consistent with synchrotron radiation at a critical energy of 740 MeV. We observe that in these two cases the data are consistent, but we make no further claims because of statistical limitations. We also extended the known energy range of electron crystal dechanneling length and channeling efficiency to 14 GeV.

  3. New Binomial Bent Function over the Finite Fields of Odd Characteristic

    CERN Document Server

    Helleseth, Tor

    2009-01-01

    The $p$-ary function $f(x)$ mapping $\\mathrm{GF}(p^{4k})$ to $\\mathrm{GF}(p)$ given by $f(x)={\\rm Tr}_{4k}\\big(x^{p^{3k}+p^{2k}-p^k+1}+x^2\\big)$ is proven to be a weakly regular bent function and the exact values of its Walsh transform coefficients are found. The proof is based on a few new results in the area of exponential sums and polynomials over finite fields that may also be interesting as independent problems.

  4. Amber Clifford-Napoleone, Queerness in heavy metal music: metal bent

    OpenAIRE

    Hill, Rosemary Lucy

    2016-01-01

    Metal Bent is an important book that sheds new light on the topic of gender and sexuality in metal music. Its aims are to queer metal and reconfigure discussion of the genre around gender and sexuality, and to move on from thinking about metal as just for “the straight boys” (3). These aims are achieved through a discussion of the style and media coverage of various musicians, and the results of a survey and interviews with queer metal fans. Central are the assertions that metal is queer and ...

  5. Observation of Multiple Volume Reflection of Ultrarelativistic Protons by a Sequence of Several Bent Silicon Crystals

    CERN Document Server

    Scandale, Walter; Baricordi, S; Dalpiaz, P; Fiorini, M; Guidi, V; Mazzolari, A; Della Mea, G; Milan, R; Ambrosi, G; Zuccon, P; Bertucci, B; Bürger, W; Duranti, M; Cavoto, G; Santacesaria, R; Valente, P; Luci, C; Iacoangeli, F; Vallazza, E; Afonin, A G; Chesnokov, Yu A; Kotov, V I; Maisheev, V A; Yazynin, I A; Kovalenko, A D; Taratin, A M; Denisov, A S; Gavrikov, Y A; Ivanov, Yu M; Lapina, L P; Malyarenko, L G; Skorogobogatov, V V; Suvorov, V M; Vavilov, S A; Bolognini, D; Hasan, S; Mozzanica, A; Prest, M

    2009-01-01

    The interactions of 400 GeV protons with different sequences of bent silicon crystals have been investigated at the H8 beam line of the CERN Super Proton Synchrotron. The multiple volume reflection of the proton beam has been studied in detail on a five-crystal reflector measuring an angular beam deflection =52.96±0.14 µrad. The efficiency was found larger than 80% for an angular acceptance at the reflector entrance of 70 µrad, with a maximal efficiency value of =0.90±0.01±0.03.

  6. High resolution x-ray and gamma ray imaging using diffraction lenses with mechanically bent crystals

    Science.gov (United States)

    Smither, Robert K.

    2008-12-23

    A method for high spatial resolution imaging of a plurality of sources of x-ray and gamma-ray radiation is provided. High quality mechanically bent diffracting crystals of 0.1 mm radial width are used for focusing the radiation and directing the radiation to an array of detectors which is used for analyzing their addition to collect data as to the location of the source of radiation. A computer is used for converting the data to an image. The invention also provides for the use of a multi-component high resolution detector array and for narrow source and detector apertures.

  7. First flight of the Gamma-Ray Imager/Polarimeter for Solar flares (GRIPS) instrument

    Science.gov (United States)

    Duncan, Nicole; Saint-Hilaire, P.; Shih, A. Y.; Hurford, G. J.; Bain, H. M.; Amman, M.; Mochizuki, B. A.; Hoberman, J.; Olson, J.; Maruca, B. A.; Godbole, N. M.; Smith, D. M.; Sample, J.; Kelley, N. A.; Zoglauer, A.; Caspi, A.; Kaufmann, P.; Boggs, S.; Lin, R. P.

    2016-07-01

    The Gamma-Ray Imager/Polarimeter for Solar flares (GRIPS) instrument is a balloon-borne telescope designed to study solar- are particle acceleration and transport. We describe GRIPS's first Antarctic long-duration flight in January 2016 and report preliminary calibration and science results. Electron and ion dynamics, particle abundances and the ambient plasma conditions in solar flares can be understood by examining hard X-ray (HXR) and gamma-ray emission (20 keV to 10 MeV). Enhanced imaging, spectroscopy and polarimetry of are emissions in this energy range are needed to study particle acceleration and transport questions. The GRIPS instrument is specifically designed to answer questions including: What causes the spatial separation between energetic electrons producing hard X-rays and energetic ions producing gamma-ray lines? How anisotropic are the relativistic electrons, and why can they dominate in the corona? How do the compositions of accelerated and ambient material vary with space and time, and why? GRIPS's key technological improvements over the current solar state of the art at HXR/gamma-ray energies, the Reuven Ramaty High Energy Solar Spectroscopic Imager (RHESSI), include 3D position-sensitive germanium detectors (3D-GeDs) and a single-grid modulation collimator, the multi-pitch rotating modulator (MPRM). The 3D-GeDs have spectral FWHM resolution of a few hundred keV and spatial resolution 150 keV, the energy deposition sites can be tracked, providing polarization measurements as well as enhanced background reduction through Compton imaging. Each of GRIPS's detectors has 298 electrode strips read out with ASIC/FPGA electronics. In GRIPS's energy range, indirect imaging methods provide higher resolution than focusing optics or Compton imaging techniques. The MPRM gridimaging system has a single-grid design which provides twice the throughput of a bi-grid imaging system like RHESSI. The grid is composed of 2.5 cm deep tungsten-copper slats, and quasi

  8. Maximal intermittent handgrip strategy: design and evaluation of an exercise protocol and a grip tool

    Directory of Open Access Journals (Sweden)

    Bentley DC

    2016-05-01

    Full Text Available Danielle Christine Bentley, Scott Gordon Thomas Faculty of Kinesiology and Physical Education, University of Toronto, Toronto, Ontario, Canada Abstract: Handgrip (HG exercise has been prescribed as a lifestyle intervention to successfully reduce resting blood pressure (BP among heterogeneous groups of participants. Current HG protocols have limited accessibility due to complicated exercise prescriptions and sophisticated required equipment. Therefore, this research describes the design and evaluation of the maximal intermittent (MINT HG exercise strategy, consisting of both a novel exercise protocol (32×5 seconds maximal grip squeezes separated by 5 seconds of rest between sets and an original grip tool. This research was a multistep progressive design that included 51 postmenopausal women as participants in three separate research studies. Part 1 of this research focuses on the MINT exercise protocol. A literature-informed rationale for the design of the protocol is described. This includes exercise intensity, work-to-rest ratio, and total exercise duration with reference to the unique physiology (mechanoreflex and metaboreflex of postmenopausal women. Subsequent experimental analyses of acute responses to the MINT protocol revealed that women produced 50% of their maximum grip force with moderate cardiovascular responses (increases of systolic BP: 41.6 mmHg, diastolic BP: 20.1 mmHg, heart rate: 35.1 bpm that remained far below the thresholds of concern identified by the American College of Sports Medicine. Part 2 of this research describes the creation of a novel grip tool, beginning with a mixed-methods assessment of participant opinions regarding two distinct in-laboratory grip tools, leading to the creation of four prototype MINT tools. Structured focus groups revealed a strong preference for MINT prototype 1 for all tool design features, including color, shape, size, and foam grip. Collectively, the result of this multistep

  9. Acoplamiento pelágico-bentónico: respuesta de la zona bentónica profunda a la sedimentación del florecimiento invernal de diatomeas en el lago oligotrófico Alchichica, Puebla, México

    OpenAIRE

    Javier Alcocer; Elva Escobar; Luis A. Oseguera

    2008-01-01

    El objetivo del presente estudio es reconocer la existencia de un acoplamiento pelágico-bentónico en el lago oligotrófico tropical Alchichica evaluando la respuesta de la zona bentónica profunda a la sedimentación del florecimiento invernal de diatomeas. Se midió la biomasa fitoplanctónica en la columna de agua a lo largo de un ciclo anual, al igual que la concentración de clorofila a sedimentaria. Alchichica es un lago monomíctico cálido con un periodo de circulación invernal y estratificaci...

  10. Peeling behavior and spalling resistance of CFRP sheets bonded to bent concrete surfaces

    Science.gov (United States)

    Yuan, Hong; Li, Faping

    2010-05-01

    In this paper, the peeling behavior and the spalling resistance effect of carbon fiber reinforced polymer (CFRP) sheets externally bonded to bent concrete surfaces are firstly investigated experimentally. Twenty one curved specimens and seven plane specimens are studied in the paper, in which curved specimens with bonded CFRP sheets can simulate the concrete spalling in tunnel, culvert, arch bridge etc., whereas plane specimens with bonded CFRP sheets can simulate the concrete spalling in beam bridge, slab bridge and pedestrian bridge. Three kinds of curved specimens with different radii of curvature are chosen by referring to practical tunnel structures, and plane specimens are used for comparison with curved ones. A peeling load is applied on the FRP sheet by loading a circular steel tube placed into the central notch of beam to debond CFRP sheets from the bent concrete surface, meanwhile full-range load-deflection curves are recorded by a MTS 831.10 Elastomer Test System. Based on the experimental results, a theoretical analysis is also conducted for the specimens. Both theoretical and experimental results show that only two material parameters, the interfacial fracture energy of CFRP-concrete interface and the tensile stiffness of CFRP sheets, are needed for describing the interfacial spalling behavior. It is found that the radius of curvature has remarkable influence on peeling load-deflection curves. The test methods and test results given in the paper are helpful and available for reference to the designer of tunnel strengthening.

  11. In vivo longitudinal micro-CT study of bent long limb bones in rat offspring.

    Science.gov (United States)

    De Schaepdrijver, Luc; Delille, Peter; Geys, Helena; Boehringer-Shahidi, Christian; Vanhove, Christian

    2014-07-01

    Micro-computed X-ray tomography (micro-CT) has been reported as a reliable method to assess ex vivo rat and rabbit fetal skeletons in embryo-fetal developmental toxicity studies. Since micro-CT is a non-invasive imaging modality it has the potential for longitudinal, in vivo investigation of postnatal skeletal development. This is the first paper using micro-CT to assess the reversibility of drug-induced bent long bones in a longitudinal study from birth to early adulthood in rat offspring. Analysis of the scans obtained on postnatal Day 0, 7, 21 and 80 showed complete recovery or repair of the bent long limb bones (including the scapula) within the first 3 weeks. When assessing risk the ability to demonstrate recovery is highly advantageous when interpreting such transient skeletal change. In summary, in vivo micro-CT of small laboratory animals can aid in non-clinical safety assessment, particularly for specific mechanistic purposes or to address a particular concern in developmental biology.

  12. Immunogold-silver staining (IGSS) based U-bent fiberoptic sandwich biosensor

    Science.gov (United States)

    Ramakrishna, B.; Sai, V. V. R.

    2016-11-01

    An evanescent wave absorbance (EWA) based U-bent fiberoptic sandwich immunobiosensor with human IgG detection limits of 6.67 fM (1 pg/ml of human IgG) and 66.7 aM (10 fg/ml of HIgG) is demonstrated by exploiting immunogold labels and subsequently silver enhancement respectively. Such very low detection limits were achieved with the help of enhanced evanescent filed at the bend region of U-bent optical fiber probe that allows efficient interaction of light with 40 nm immunogold labels on the probe surface resulting in measurable optical absorbance changes. The other significant advantages of the demonstrated sensing scheme are low cost optoelectronic instrumentation consisting of an commercial green LED and a photodetector (S150C, Thorlabs Inc.), small volumes of sample and immunogold reagent each of 25 μl and rapid detection in 20 min. These results from the plasmonic fiberoptic biosensor demonstrate its huge potential for development of point-of-care diagnostic devices for sensitive and rapid detection of analytes.

  13. Experimentally determining the relative efficiency of spherically bent germanium and quartz crystals

    Science.gov (United States)

    Brown, G. V.; Beiersdorfer, P.; Hell, N.; Magee, E.

    2016-11-01

    We have used the EBIT-I electron beam ion trap at the Lawrence Livermore National Laboratory and a duplicate Orion High Resolution X-ray Spectrometer (OHREX) to measure the relative efficiency of a spherically bent quartz (10 1 ¯ 1) crystal (2d = 6.687 Å) and a spherically bent germanium (111) crystal (2d = 6.532 Å). L-shell X-ray photons from highly charged molybdenum ions generated in EBIT-I were simultaneously focussed and Bragg reflected by each crystal, both housed in a single spectrometer, onto a single CCD X-ray detector. The flux from each crystal was then directly compared. Our results show that the germanium crystal has a reflection efficiency significantly better than the quartz crystal, however, the energy resolution is significantly worse. Moreover, we find that the spatial focussing properties of the germanium crystal are worse than those of the quartz crystal. Details of the experiment are presented, and we discuss the advantages of using either crystal on a streak-camera equipped OHREX spectrometer.

  14. Investigation of Momentum Resolution in Straight vs Bent Large End-Cap Chambers

    CERN Document Server

    Levin, D S

    1999-01-01

    We report on a calculation of momentum resolution for muons incident on the large end-cap chambers. The impact on the resolution of two chamber designs was evaluated: Those constructed with straight drift tubes are compared to the ATLAS baseline design in which chambers are bent such that tube axes conform to the catenary of their respective anode wires. The analysis was performed using the GARFIELD program to calculate drift tube time-to-space functions. ATLAS muon system code packages LHCTOR and MUONBOX were used to generate tracks, hits and momentum reconstruction. We find that, for straight tube chambers compared to bent ones, the overall degradation in momentum resolution, averaged over all of the largest of the so called large end-cap chambers (EML4-5 and EOL3 in the pseudo-rapidity range$1.02 < \\eta <1.49$), is very small for muon transverse momentum $P_t = 500 $ Gev and negligible for $P_t \\le 100 $ Gev. When the intermediate large end-cap chambers (EEL1 and EEL2) are considered no momentum degr...

  15. Bent Polytypic ZnSe and CdSe Nanowires Probed by Photoluminescence.

    Science.gov (United States)

    Kim, Yejin; Im, Hyung Soon; Park, Kidong; Kim, Jundong; Ahn, Jae-Pyoung; Yoo, Seung Jo; Kim, Jin-Gyu; Park, Jeunghee

    2017-05-01

    Nanowires (NWs) have witnessed tremendous development over the past two decades owing to their varying potential applications. Semiconductor NWs often contain stacking faults due to the presence of coexisting phases, which frequently hampers their use. Herein, it is investigated how stacking faults affect the optical properties of bent ZnSe and CdSe NWs, which are synthesized using the vapor transport method. Polytypic zinc blende-wurtzite structures are produced for both these NWs by altering the growth conditions. The NWs are bent by the mechanical buckling of poly(dimethylsilioxane), and micro-photoluminescence (PL) spectra were then collected for individual NWs with various bending strains (0-2%). The PL measurements show peak broadening and red shifts of the near-band-edge emission as the bending strain increases, indicating that the bandgap decreases with increasing the bending strain. Remarkably, the bandgap decrease is more significant for the polytypic NWs than for the single phase NWs. This work provides insights into flexible electronic devices of 1D nanostructures by engineering the polytypic structures. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  16. Cell Area and Strut Distribution Changes of Bent Coronary Stents: A Finite Element Analysis

    Institute of Scientific and Technical Information of China (English)

    ZHAO Yang; WU Wei; YANG Da-zhi; QI Min

    2009-01-01

    Coronary stents are metal coils or mesh tubes delivered to blocked vessels through catheters, which are expanded by balloons to reopen and scaffold target vessels. Recently,special drugs are carried by stents (drug-eluting stents) to further reduce in-stent restenosis rate after stenting procedure. However,continual study on biomechanical characteristics of stents is necessary for better interactions between stents and tissue, or to provide a more suitable drug loading platform for drug-eluting stents. The purpose of this paper is to show how finite element methods can be used to study cell area and strut distribution changes of bent coronary stents. A same bending deformation was applied to two commercial coronary stent models by a rigid curved vessel. Results show that the stent design influenced the changes of cell area and strut distribution under bending situation. The stent with links had more cell area changes at outer curvature, and the stent with peak-peak (><) strut design could have strut contact and overlapping at inner curvature. In conclusion, this finite element method can be used to study and compare cell area and strut distribution changes of bent stents,and to provide a convenient tool for designers in testing and improving biomechanical characteristics of new stents.

  17. On the discrete spectrum of the Dirac operator on bent chain quantum graph

    Directory of Open Access Journals (Sweden)

    Belov Michail

    2017-01-01

    Full Text Available We study Dirac operators on an infinite quantum graph of a bent chain form which consists of identical rings connected at the touching points by δ-couplings with a parameter α ∈ ℝ. We are interested in the discrete spectrum of the corresponding Hamiltonian. It can be non-empty due to a local (geometrical perturbation of the corresponding infinite chain of rings. The quantum graph of analogous geometry with the Schrodinger operator on the edges was considered by Duclos, Exner and Turek in 2008. They showed that the absence of δ-couplings at vertices (i.e. the Kirchhoff condition at the vertices lead to the absence of eigenvalues. We consider the relativistic particle (the Dirac operator instead of the Schrodinger one but the result is analogous. Quantum graphs of such type are suitable for description of grapheme-based nanostructures. It is established that the negativity of α is the necessary and sufficient condition for the existence of eigenvalues of the Dirac operator (i.e. the discrete spectrum of the Hamiltonian in this case is not empty. The continuous spectrum of the Hamiltonian for bent chain graph coincides with that for the corresponding straight infinite chain. Conditions for appearance of more than one eigenvalue are obtained. It is related to the bending angle. The investigation is based on the transfer-matrix approach. It allows one to reduce the problem to an algebraic task. δ-couplings was introduced by the operator extensions theory method.

  18. The High-redshift Clusters Occupied by Bent Radio AGN (COBRA) Survey: The Spitzer Catalog

    Science.gov (United States)

    Paterno-Mahler, R.; Blanton, E. L.; Brodwin, M.; Ashby, M. L. N.; Golden-Marx, E.; Decker, B.; Wing, J. D.; Anand, G.

    2017-07-01

    We present 190 galaxy cluster candidates (most at high redshift) based on galaxy overdensity measurements in the Spitzer/IRAC imaging of the fields surrounding 646 bent, double-lobed radio sources drawn from the Clusters Occupied by Bent Radio AGN (COBRA) Survey. The COBRA sources were chosen as objects in the Very Large Array FIRST survey that lack optical counterparts in the Sloan Digital Sky Survey to a limit of m r = 22, making them likely to lie at high redshift. This is confirmed by our observations: the redshift distribution of COBRA sources with estimated redshifts peaks near z = 1 and extends out to z≈ 3. Cluster candidates were identified by comparing our target fields to a background field and searching for statistically significant (≥slant 2σ ) excesses in the galaxy number counts surrounding the radio sources; 190 fields satisfy the ≥slant 2σ limit. We find that 530 fields (82.0%) have a net positive excess of galaxies surrounding the radio source. Many of the fields with positive excesses but below the 2σ cutoff are likely to be galaxy groups. Forty-one COBRA sources are quasars with known spectroscopic redshifts, which may be tracers of some of the most distant clusters known.

  19. Measuring the x-ray resolving power of bent potassium acid phthalate diffraction crystalsa)

    Science.gov (United States)

    Haugh, M. J.; Wu, M.; Jacoby, K. D.; Loisel, G. P.

    2014-11-01

    This report presents the results from measuring the X-ray resolving power of a curved potassium acid phthalate (KAP(001)) spectrometer crystal using two independent methods. It is part of a continuing effort to measure the fundamental diffraction properties of bent crystals that are used to study various characteristics of high temperature plasmas. Bent crystals like KAP(001) do not usually have the same diffraction properties as corresponding flat crystals. Models that do exist to calculate the effect of bending the crystal on the diffraction properties have simplifying assumptions and their accuracy limits have not been adequately determined. The type of crystals that we measured is being used in a spectrometer on the Z machine at Sandia National Laboratories in Albuquerque, New Mexico. The first technique for measuring the crystal resolving power measures the X-ray spectral line width of the characteristic lines from several metal anodes. The second method uses a diode X-ray source and a double crystal diffractometer arrangement to measure the reflectivity curve of the KAP(001) crystal. The width of that curve is inversely proportional to the crystal resolving power. The measurement results are analyzed and discussed.

  20. Measuring the X-ray Resolving Power of Bent Potassium Acid Phthalate Diffraction Crystals

    Energy Technology Data Exchange (ETDEWEB)

    Haugh, M. J. [NSTec; Wu, M. [SNL; Jacoby, K. D. [NSTec; Loisel, G. P. [SNL

    2014-11-01

    This report presents the results from measuring the X-ray resolving power of a curved potassium acid phthalate (KAP(001)) spectrometer crystal using two independent methods. It is part of a continuing effort to measure the fundamental diffraction properties of bent crystals that are used to study various characteristics of high temperature plasmas. Bent crystals like KAP(001) do not usually have the same diffraction properties as corresponding flat crystals. Models that do exist to calculate the effect of bending the crystal on the diffraction properties have simplifying assumptions and their accuracy limits have not been adequately determined. The type of crystals that we measured is being used in a spectrometer on the Z machine at Sandia National Laboratories (SNL) in Albuquerque, NM. The first technique for measuring the crystal resolving power measures the X-ray spectral line width of the characteristic lines from several metal anodes. The second method uses a diode X-ray source and a dual goniometer arrangement to measure the reflectivity curve of the KAP(001) crystal. The width of that curve is inversely proportional to the crystal resolving power. The measurement results are analyzed and discussed.

  1. New results from the CERN-SPS beam deflection experiments with bent crystals

    Science.gov (United States)

    Baurichter, A.; Kirsebom, K.; Medenwaldt, R.; Møller, S. P.; Worm, T.; Uggerhøj, E.; Mikkelsen, U.; Graftström, P.; Gatignon, L.; Elsener, K.; Doble, N.; Biino, C.; Freund, A.; Vilakazi, Z.; Hage-Ali, M.; Siffert, P.; Clément, M.

    1996-10-01

    Results from five distinct bending experiments performed recently in the H8 beam at CERN are presented. Firstly, deflection of a positive pion beam at 200 GeV/c is compared to the "standard" 450-GeV/c proton beam for a bending angle of 3.1 mrad along the (111) plane in a 50 mm silicon crystal. Second, deflection of negative pions at 200 GeV/c is investigated for the same crystal, for incidence along the (111) plane as well as the axis. Small deflection effects are seen, but no negative particles are bent through the full bending angle of the crystal. Third, the first results from beam deflection at high energy using a germanium crystal are shown. Slightly higher deflection efficiencies than for silicon are seen for large bending angles, but significantly smaller than expected for such a crystal with higher atomic number. Fourth, deflection efficiencies using a strongly irradiated silicon crystal have been measured for the first time, and a small reduction in efficiency is seen in the irradiated region. Finally, deflection of positive particles using axial alignment of a bent silicon crystal has been investigated at 450 GeV/c. Qualitatively similar behaviour as in previous experiments at 12 GeV/c is seen; the beam splits into several beams corresponding to the different planes, and even weak planes are observed.

  2. Bent π-conjugated systems composed of three-dimensional benzoannulenes.

    Science.gov (United States)

    Nishiuchi, Tomohiko; Iyoda, Masahiko

    2015-02-01

    This article describes bent π-conjugated systems composed of alternating o-phenylene and Z-vinylene units. all-Z-[n]Benzo[4n]annulenes are higher homologues of dibenzocyclooctatetraene (DBCOT) with a concave π system, and attempts were made to convert [20]- and [24]annulenes having partial belt structures of fullerenes and carbon nanotubes into [10]- and [12]phenacenes. A bent π-conjugated system composed of two DBCOT units showed dynamic syn-anti equilibrium in solution and behaved as dynamic molecular tweezers (DMTs). The syn isomers of the DMTs formed blue charge-transfer complexes with DDQ in solution, and this complexation and color change were applied to thermochromism. Furthermore, DMTs having two CN groups on each COT ring exhibited crystalline-state emission in the presence of solvent molecules, although almost no emission was observed in solution or the solid state. Based on this crystalline-state emission, a vapochromic system was established. The multifunctional properties of DMTs caused by the flexibility of the nonplanar π system are summarized.

  3. Bent silicon crystals for the LHC collimation Studies with an ultrarelativistic proton beam

    CERN Document Server

    Hasan, Said; Scandale, Walter; Vallazza, Erik

    2007-01-01

    LHC is a source of new challenges in every HEP field; among these, the beam collimation requires an innovative approach. The H8RD22 collaboration is undertaking an intense study of bent crystal properties with the goal of using crystals as primary collimators. The thesis gives an introduction to the theory of channeling and its related phenomena in bent crystals explaining how these can be used to perform an efficient beam collimation. The pre-thesis experiments are described to introduce the scientific context in which the H8RD22 collaboration is working. The thesis core is the description of two beam tests held in Sept. 2006 and May 2007 on the CERN SPS H8 beamline with 400 GeV/c protons: the experimental setups and procedures are shown together with the analysis of the collected data. With the observation of the volume reflection for the first time at these energies and the use of multi crystal systems, these experiments are a clear indication that crystal collimation is a real possibility for the second p...

  4. Triggering and measuring bent cosmic muon tracks with the Muon Spectrometer barrel for the first time

    CERN Multimedia

    Fabio Cerutti

    During the ATLAS barrel toroid stability test, bent cosmic muon tracks were seen for the first time in the ATLAS cavern by means of the ATLAS muon spectrometer. The barrel toroid has been powered at its nominal current (20.5 thousand Amperes) and kept in steady state for more than one day during the weekend of 18-19 November (see a report on this test in the Magnet section). During this test one large sector and part of a small sector of the barrel muon spectrometer were readout and used to detect the cosmic muons tracks bent by the toroidal magnetic field. Thirteen muon stations in the feet sectors (sectors 13 and 14) have been used in this test. The muon stations are formed of Resistive Plate Chambers (RPC) that were providing the muon trigger, and Monitored Drift Tubes that were used to measure with high accuracy the muon curvature hence their momentum. The Level-1 Barrel trigger chain was based on the Barrel Middle Large chambers equipped with final production modules on both the on-detector and the o...

  5. Deflection and Extraction of Pb Ions up to 33 TeV/c by a Bent Silicon Crystal

    Energy Technology Data Exchange (ETDEWEB)

    Arduini, G.; Biino, C.; Clement, M.; Cornelis, K.; Doble, N.; Elsener, K.; Ferioli, G.; Fidecaro, G.; Gatignon, L.; Grafstroem, P.; Gyr, M.; Herr, W.; Klem, J.; Mikkelsen, U.; Weisse, E. [SL Division, CERN, CH-1211 Geneva 23 (Switzerland); Mo/ller, S.P.; Uggerho/j, E. [ISA, Aarhus University (Denmark); Taratin, A. [JINR, Dubna (Russia); Freund, A. [ESRF, Grenoble (France); Keppler, P.; Major, J. [MPI fuer Metallforschung, Stuttgart (Germany)

    1997-11-01

    The first results from an experiment to deflect a beam of fully stripped, ultrarelativistic Pb{sup 82+} ions of 400 GeV/c per unit of charge, equivalent to 33 TeV/c , by means of a bent crystal are reported. Deflection efficiencies are as high as 14{percent}, in agreement with theoretical estimates. In a second experiment a bent crystal was used to extract 270 GeV/c -per-charge Pb{sup 82+} (22 TeV/c) ions from a coasting beam in the CERN-SPS, and a high extraction efficiency of up to 10{percent} was found. These represent the first measurements to demonstrate applications of bent crystals in high energy heavy ion beams. {copyright} {ital 1997} {ital The American Physical Society}

  6. Deflection and Extraction of Pb Ions up to 33 TeV/c by a Bent Silicon Crystal

    Science.gov (United States)

    Arduini, G.; Biino, C.; Clément, M.; Cornelis, K.; Doble, N.; Elsener, K.; Ferioli, G.; Fidecaro, G.; Gatignon, L.; Grafström, P.; Gyr, M.; Herr, W.; Klem, J.; Mikkelsen, U.; Weisse, E.; Møller, S. P.; Uggerhøj, E.; Taratin, A.; Freund, A.; Keppler, P.; Major, J.

    1997-11-01

    The first results from an experiment to deflect a beam of fully stripped, ultrarelativistic Pb82+ ions of 400 GeV/c per unit of charge, equivalent to 33 TeV/c, by means of a bent crystal are reported. Deflection efficiencies are as high as 14%, in agreement with theoretical estimates. In a second experiment a bent crystal was used to extract 270 GeV/c-per-charge Pb82+ \\(22 TeV/c\\) ions from a coasting beam in the CERN-SPS, and a high extraction efficiency of up to 10% was found. These represent the first measurements to demonstrate applications of bent crystals in high energy heavy ion beams.

  7. Deflection and extraction of Pb ions up to 33 TeV/c by a bent silicon crystal

    CERN Document Server

    Arduini, Gianluigi; Clément, M; Cornelis, Karel; Doble, Niels T; Elsener, K; Ferioli, G; Fidecaro, Giuseppe; Freund, A; Gatignon, L; Grafström, P; Gyr, Marcel; Herr, Werner; Keppler, P; Klem, J T; Major, J V; Mikkelsen, U; Møller, S P; Taratin, A M; Uggerhøj, Erik; Weisse, E

    1997-01-01

    The first results from an experiment to deflect a beam of fully stripped, ulta-relativistic Pb ions of 400 GeV/c per unit of charge, equivalent to 33 TeV/c, by means of a bent crystal are reported. Deflection efficiencies are as high as 14%, in agreement with theoretical predictions. In a second experiment a bent crsytal was used to extract 270 GeV/c per charge Pb82+ (22 TeV/c) ions from a coasting beam in the CERN-SPS, and a high extraction efficiency of up to 10% was found. These represent the first measurements to demonstrate applications of bent crystals in high energy heavy ion beams.

  8. Development of normative data for hand strength and anthropometric dimensions in a population of automotive workers.

    Science.gov (United States)

    Kunelius, Amanda; Darzins, Susan; Cromie, Jean; Oakman, Jodi

    2007-01-01

    (1) To develop a normative data set for hand strength and anthropometric dimensions in automotive trim line workers. (2) To examine the relationship between trim line worker demographics and hand strength. Work tasks inherent in the automobile manufacturing industry such as forceful gripping and pinching, place physical demands upon the hands and fingers. This places workers at risk of developing a musculoskeletal injury. To reduce the risk of injury it is necessary to apply user strength data in the design phase of hand intensive tasks in order to create a fit between the person and the task. Demographic variables, anthropometry and maximal grip and pinch strength were measured for one hundred and sixty-one trim line automotive workers. Their data were analyzed to examine the associations between the variables. Significant hand strength differences were found in relation to age, gender, hand dominance and anthropometry. The workers in this study had significantly lower strength values than previously used reference data. The disparity between the present study's strength data and that of Mathiowetz et al. [22] may be due to the different demographic pools from which the populations were drawn. A training effect appeared to exist in trim line workers which may have reduced the disparity in hand strength between the hands as the number of years worked on the line increased. Caution should be taken when applying international normative data sets to the design of hand tools/workstations, as global differences in hand strength are likely to exist.

  9. Angiotensin-converting enzyme genotype affects skeletal muscle strength in elite athletes.

    Science.gov (United States)

    Costa, Aldo Matos; Silva, António José; Garrido, Nuno; Louro, Hugo; Marinho, Daniel Almeida; Cardoso Marques, Mário; Breitenfeld, Luiza

    2009-01-01

    Previous studies have associated angiotensin-converting enzyme (ACE) D allele with variability in the skeletal muscle baseline strength, though conclusions have been inconsistent across investigations. The purpose of this study was to examine the possible association between ACE genotype and skeletal muscle baseline strength in elite male and female athletes involved in different event expertise. A group of 58 elite athletes, designated as Olympic candidates, were studied: 35 swimmers (19 males and 16 females, 18.8 ± 3.2 years) and 23 triathletes (15 males and 8 females, 18.7 ± 3.0 years). The athletes were classified as: short (≤ 200m) and middle (400m to 1500m) distance athletes, respectively. For each subject the grip strength in both hands was measure using an adjustable mechanical hand dynamometer. The maximum height in both squat jump (SJ) and counter movement jump (CMJ) were also assessed, using a trigonometric carpet (Ergojump Digitime 1000; Digitest, Jyvaskyla, Finland). DNA extraction was obtained with Chelex 100(®) and genotype determination by PCR-RFLP methods. Both males and females showed significantly higher right grip strength in D allele carriers compared to II homozygote's. We found that allelic frequency differs significantly by event distance specialization in both genders (p sprinter D allele carriers showed the superior scores in nearly all strength measurements (p < 0.05), in both genders. Among endurance athletes, the results also demonstrated that female D allele carriers exhibited the higher performance right grip and CMJ scores (p < 0.05). In conclusion, the ACE D allele seems associated with skeletal muscle baseline strength in elite athletes, being easily identified in females. Key pointsDD homozygote's and D allele carriers from both genders shows significantly higher right grip strength.Right grip strength remains significantly higher in the D allele carrier's female endurance group.Female's D allele carriers exhibited the higher

  10. Test-retest reliability of handgrip strength measurement using a hydraulic hand dynamometer in patients with cervical radiculopathy.

    Science.gov (United States)

    Savva, Christos; Giakas, Giannis; Efstathiou, Michalis; Karagiannis, Christos

    2014-01-01

    The purpose of this study was to evaluate the test-retest reliability of handgrip strength measurement using a hydraulic hand dynamometer in patients with cervical radiculopathy (CR). A convenience sample of 19 participants (14 men and 5 women; mean ± SD age, 50.5 ± 12 years) with CR was measured using a Jamar hydraulic hand dynamometer by the same rater on 2 different testing sessions with an interval of 7 days between sessions. Data collection procedures followed standardized grip strength testing guidelines established by the American Society of Hand Therapists. During the repeated measures, patients were advised to rest their upper limb in the standardized arm position and encouraged to exert 3 maximum gripping efforts. The mean value of the 3 efforts (measured in kilogram force [Kgf]) was used for data analysis. The intraclass correlation coefficient, SEM, and the Bland-Altman plot were used to estimate test-retest reliability and measurement precision. Grip strength measurement in CR demonstrated an intraclass correlation coefficient of 0.976, suggesting excellent test-retest reliability. The small SEM in both testing sessions (SEM1, 2.41 Kgf; SEM2, 2.51 Kgf) as well as the narrow width of the 95% limits of agreements (95% limits of agreement, -4.9 to 4.4 Kgf) in the Bland-Altman plot reflected precise measurements of grip strength in both occasions. Excellent test-retest reliability for grip strength measurement was measured in patients with CR, demonstrating that a hydraulic hand dynamometer could be used as an outcome measure for these patients. Copyright © 2014 National University of Health Sciences. Published by Mosby, Inc. All rights reserved.

  11. Freezing grip - new application of the Peltier technology; Gefriergreifer - neue Anwendung der Peltier-Technik

    Energy Technology Data Exchange (ETDEWEB)

    Jensen, L.; Stephan, J. [NAISS GmbH, Berlin (Germany)

    2002-12-01

    The rising requirements in efficiency and quality lead to products of in addition integration and functionality with ever smaller components. In addition new materials with improved characteristics are used e.g. GRP components plastics. Due to the characteristics of miniature units and new materials an automated assembling process becomes ever more difficult. With CRYO grip gripping tools were developed, which transport material units and carefully. (orig.) [German] Die steigenden Anforderungen an Leistungsfaehigkeit und Qualitaet fuehren zu Produkten hoeherer Integration und Funktionalitaet mit immer kleineren Komponenten. Ausserdem kommt es zur Anwendung neuer Werkstoffe mit verbesserten Eigenschaften wie z. B. Faserverbundkunststoffen. Aufgrund der Eigenschaften von Miniaturbauteilen und neuer Materialien wird ein automatisierter Montageprozess immer schwieriger. Mit CRYO-Greifern sind Greifwerkzeuge entwickelt worden, die materialschonend und sicher solche Bauteile transportieren. (orig.)

  12. A Monte Carlo-tuned model of the flow in the NorthGRIP area

    DEFF Research Database (Denmark)

    Grinsted, Aslak; Dahl-Jensen, Dorthe

    2002-01-01

    The North Greenland Icecore Project (NorthGRIP) drill site was chosen in order to obtain a good Eemian record. At the present depth, 3001m, the Eemian interstadial has yet to be seen. Clearly the flow in this area is poorly understood and needs further investigation. After a review of specific...... no Eemian is observed is a high basal melt rate (2.7mm/a). The melting is a consequence of a higher geothermal heat flux than the expected 51mW/m^2 of the Precambrian shield. From our analyses it is concluded that the geothermal heat flux at NorthGRIP is 98mW/m^2.The high basalmelt rate also gives rise...

  13. Dynamics of Crystal Formation in the Greenland NorthGRIP Ice Core

    CERN Document Server

    Mathiesen, J; Jensen, M H; Levinsen, M; Olesen, P; Dahl-Jensen, D; Svensson, A; Mathiesen, Joachim; Ferkinghoff-Borg, Jesper; Jensen, Mogens H.; Levinsen, Mogens; Olesen, Poul; Dahl-Jensen, Dorthe; Svensson, Anders

    2003-01-01

    The North Greenland Ice Core Project (NorthGRIP) provides paleoclimatic information back to at least 115 kyr before present [Dahl-Jensen et al., 2002]. Each year, precipitation on the ice sheet covers it with a new layer of snow, which gradually transforms into ice crystals as the layer sinks into the ice sheet. The size distribution of ice crystals has been measured at selected depths in the upper 880 m of the NorthGRIP ice core [Svensson et al., 2003b], which cover a time span of 5300 years. The distributions change with time toward a universal curve, indicating a common underlying physical process in the formation of crystals. We identify this process as an interplay between fragmentation of the crystals and diffusion of their grain boundaries. The process is described by a two-parameter differential equation to which we obtain the exact solution. The solution is in excellent agreement with the experimentally observed distributions.

  14. Randomized clinical trial of self-gripping mesh versus sutured mesh for Lichtenstein hernia repair

    DEFF Research Database (Denmark)

    Jorgensen, L N; Sommer, T; Assaadzadeh, S;

    2012-01-01

    between the groups in postoperative complications (33·7 versus 40·4 per cent; P = 0·215), rate of recurrent hernia within 1 year (1·2 per cent in both groups) or quality of life. CONCLUSION: The avoidance of suture fixation using a self-gripping mesh was not accompanied by a reduction in chronic symptoms......BACKGROUND: Many patients develop discomfort after open repair of a groin hernia. It was hypothesized that suture fixation of the mesh is a cause of these symptoms. METHODS: This patient- and assessor-blinded randomized multicentre clinical trial compared a self-gripping mesh (Parietene Progrip......(®) ) and sutured mesh for open primary repair of uncomplicated inguinal hernia by the Lichtenstein technique. Patients were assessed before surgery, on the day of operation, and at 1 and 12 months after surgery. The primary endpoint was moderate or severe symptoms after 12 months, including a combination...

  15. Coefficient of variation in maximal and feigned static and dynamic grip efforts.

    Science.gov (United States)

    Dvir, Z

    1999-01-01

    The purpose of this study was to investigate the validity of the coefficient of variation as an identifier of feigned grip effort. Seventeen healthy female aged 20 to 25 yr participated in the study. Maximal and feigned efforts were measured isometrically and isokinetically (concentric and eccentric) using the Jamar and KinCom dynamometers, respectively. Findings indicated that, in all situations, the coefficient of variation derived from the maximal effort was significantly (P < 0.0001) lower than that derived from the feigned effort. However, the extent of overlapping between the two was sufficiently large to render the test sensitivities very low. Consequently, regardless of the measurement method, the coefficient of variation is not a valid tool for identifying feigned grip effort in healthy subjects.

  16. First flight of the Gamma-Ray Imager/Polarimeter for Solar flares (GRIPS)

    Science.gov (United States)

    Saint-Hilaire, Pascal; Shih, Albert Y.; Duncan, Nicole; Bain, Hazel; Maruca, Bennett A.; Kelley, Nicole; Godbole, Niharika; Kaufmann, Pierre; Caspi, Amir; Sample, John; Hoberman, Jane; Mochizuki, Brent; Olson, Jerry; Boggs, Steven E.; Zoglauer, Andreas; Hurford, Gordon J.; Smith, David M.; Tajima, Hiroyasu; Amman, Mark

    2016-05-01

    The Gamma-Ray Imager/Polarimeter for Solar flares (GRIPS) high altitude balloon payload was successfully flown in January 2016 from Antarctica (Jan 19 to Jan 30).GRIPS provides a near-optimal combination of high-resolution imaging, spectroscopy, and polarimetry of solar-flare gamma ray/hard X-ray emissions from ~20 keV to >~10 MeV. GRIPS’s goal is to address questions raised by recent solar flare observations regarding particle acceleration and energy release, such as: What causes the spatial separation between energetic electrons producing hard X-rays and energetic ions producing gamma-ray lines? How anisotropic are the relativistic electrons, and why can they dominate in the corona? How do the compositions of accelerated and ambient material vary with space and time, and why? The spectrometer/polarimeter consists of six 3D position-sensitive germanium detectors (3D-GeDs), where each energy deposition is individually recorded with an energy resolution of a few keV FWHM and a spatial resolution gamma-ray energies (12.5 arcsec FWHM), sufficient to separate 2.2 MeV footpoint sources for almost all flares. Polarimetry is accomplished by analyzing the anisotropy of reconstructed Compton scattering in the 3D-GeDs, with an estimated minimum detectable polarization of a few percent at 150-650 keV in an X-class flare. GRIPS was also equipped with active BGO shields, and three piggy-back instruments: a solar terahertz radiometer (Solar-T), a hard X-ray spectrometer (SMASH), and a sonic anemometer (TILDAE).We will present an overview of GRIPS's first flight, the performance of its instruments and subsystems, including the solar pointing and aspect systems, and the current progress of our data analysis.

  17. Effect of paddle grip on segmental fluid distribution in elite slalom paddlers.

    Science.gov (United States)

    Bílý, Milan; Baláš, Jiří; Martin, Andrew John; Cochrane, Darryl; Coufalová, Klára; Süss, Vladimír

    2013-01-01

    Issues of high levels of muscular asymmetry have been associated with injury risk, and therefore have potential implications for decremental performance at the elite sport level. The aim of this current study was to assess the relationship between the segmental fluid distribution and the paddle grip in elite male and female slalom kayakers and canoeists. Eighty-four world-cup competitors (61 males and 23 females) took part in the study. Impedance analysis was used to assess segmental fluid asymmetry. The effect of paddle grip (loose/fixed hand in kayakers, lower/upper hand in canoeists), morphological dominance (dominant/non-dominant) and discipline (canoe/kayak) were evaluated by repeated measures ANOVA. The findings indicated a significant effect of paddle grip in canoeists on morphological asymmetry in upper limbs (arm of lower paddle hand mean fluid distribution 3.28, s=0.43 litres; arm of upper paddle hand mean fluid distribution 3.19, s=0.41 litres; P=0.000, [Formula: see text]=0.33). The sternmen demonstrated higher asymmetry between the arms of upper and lower paddle hand (mean 0.11, s=0.04 litres, P=0.000, [Formula: see text]=0.80) than the bowmen (mean 0.04, s=0.06 litres, P=0.015, [Formula: see text]=0.44) in double-canoes. Significant morphological asymmetry was found also in kayakers but the effect of paddle grip was not substantial. The use of segmental impedance analysis may be a suitable diagnostic tool for assessing morphological changes, which can be related to paddling training. Likewise muscular asymmetry is associated with injury risk; the evaluation of morphological changes during the training process may be considered by sport trainers and physical therapists.

  18. Tension free open inguinal hernia repair using an innovative self gripping semi-resorbable mesh

    Directory of Open Access Journals (Sweden)

    Chastan Philippe

    2006-01-01

    Full Text Available Aims: Inguinal hernia repair according to Lichtenstein technique has become the most common procedure performed by general surgeons. Heavy weight polypropylene meshes have been reported to stimulate inflammatory reaction responsible for mesh shrinkage when scar tissue evolved. Additionally, some concerns remain regarding the relationship between chronic pain and mesh fixation technique. In order to reduce those drawbacks, we have developed a new mesh for anterior tension free inguinal hernia repair which exhibits self-gripping absorbable properties. Materials and Methods: 52 patients (69 hernias were prospectivly operated with this mesh (SOFRADIM-France made of low-weight isoelastic large pores knitted fabric which incorporated resorbable micro hooks that provides self gripping properties to the mesh during the first months post-implantation. The fixation of the mesh onto the tissues is significantly facilitated. The mesh is secured around the cord with a self gripping flap. After complete tissular ingrowth and resorption of the PLA hooks, the low-weight (40 g/m2 polypropylene mesh insures the long term wall reinforcement. Results: Peroperativly, no complication was reported, the mesh was easy to handle and to fix. Discharge was obtained at Day 1. No perioperative complication occurred, return to daily activities was obtained at Day 5.5. At one month, no neurological pain or other complications were described. Conclusions: Based on the first results of this clinical study, this unique concept of low density self gripping mesh should allows an efficient treatment of inguinal hernia. It should reduce postoperative complications and the extent of required suture fixation, making the procedure more reproducible

  19. Role of movement velocity on the magnitude of grip force while lifting an object with touch from the contralateral finger.

    Science.gov (United States)

    Iyengar, Veena; Santos, Marcio J; Aruin, Alexander S

    2009-04-01

    We investigated whether slower velocity of arm movement affects grip-force generation in conditions with the finger touch provided to the wrist of the target arm. Nine subjects performed the task of lifting and transporting an object at slow, intermediate, and fast velocities with a light finger touch from the contralateral arm and without it. There was an effect of velocity of arm movement on grip-force generation in both conditions. However, when the no touch and touch trials performed with similar velocity were matched, the effect of touch on grip-force reduction was statistically significant (p touch conditions and underlines the importance of using a contralateral touch in the performance of activities of daily living. It also points to a possibility of the development of therapeutic advances for the enhancement of grip-force control in patients with neurological impairments.

  20. Broadband tunable external cavity laser using a bent-waveguide quantum-dot superluminescent diode as gain device

    Institute of Scientific and Technical Information of China (English)

    Wu Jian; Lü Xue-Qin; Jin Peng; Meng Xian-Quan; Wang Zhan-Guo

    2011-01-01

    A broadband tunable grating-coupled external cavity laser is realized by employing a self-assembled InAs/GaAs quantum-dot (QD) superluminescent diode (SLD) as the gain device. The SLD device is processed with a bent-waveguide structure and facet antireflection (AR) coating. Tuning bandwidths of 106 nm and 117 nm are achieved under 3-A and 3.5-A injection currents, respectively. The large tuning range originates essentially from the broad gain spectrum of self-assembled QDs. The bent waveguide structure combined with the facet AR coating plays a role in suppressing the inner-cavity lasing under a large injection current.

  1. The Influence of Radiation Damage on the Deflection of High-Energy Beams in Bent Silicon Crystals

    CERN Document Server

    Biino, C; Doble, Niels T; Elsener, K; Gatignon, L; Grafström, P; Mikkelsen, U; Kirsebom, K; Møller, S P; Uggerhøj, Erik; Worm, T

    1996-01-01

    Experimental results obtained for deflection of 450 GeV/c protons channeling along the {111} planes in a bent, strongly irradiated silicon crystal are presented. A comparison between the deflection efficiencies in irradiated areas and non-irradiated areas in the crystal shows that irradiation by 2.4 · 1020 protons/cm2 leads to a reduction of around 30 % in deflection efficiency. As a consequence, beam-splitting and extraction from an accelerator by means of a bent crystal are feasible solutions at high energies even for intense beams and during long periods.

  2. Flash Detection Efficiencies of Long Range Lightning Detection Networks During GRIP

    Science.gov (United States)

    Mach, Douglas M.; Bateman, Monte G.; Blakeslee, Richard J.

    2012-01-01

    We flew our Lightning Instrument Package (LIP) on the NASA Global Hawk as a part of the Genesis and Rapid Intensification Processes (GRIP) field program. The GRIP program was a NASA Earth science field experiment during the months of August and September, 2010. During the program, the LIP detected lighting from 48 of the 213 of the storms overflown by the Global Hawk. The time and location of tagged LIP flashes can be used as a "ground truth" dataset for checking the detection efficiency of the various long or extended range ground-based lightning detection systems available during the GRIP program. The systems analyzed included Vaisala Long Range (LR), Vaisala GLD360, the World Wide Lightning Location Network (WWLLN), and the Earth Networks Total Lightning Network (ENTLN). The long term goal of our research is to help understand the advantages and limitations of these systems so that we can utilize them for both proxy data applications and cross sensor validation of the GOES-R Geostationary Lightning Mapper (GLM) sensor when it is launched in the 2015 timeframe.

  3. A simple technique to study embodied language processes: the grip force sensor.

    Science.gov (United States)

    Nazir, Tatjana A; Hrycyk, Lianna; Moreau, Quentin; Frak, Victor; Cheylus, Anne; Ott, Laurent; Lindemann, Oliver; Fischer, Martin H; Paulignan, Yves; Delevoye-Turrell, Yvonne

    2017-02-01

    Research in cognitive neuroscience has shown that brain structures serving perceptual, emotional, and motor processes are also recruited during the understanding of language when it refers to emotion, perception, and action. However, the exact linguistic and extralinguistic conditions under which such language-induced activity in modality-specific cortex is triggered are not yet well understood. The purpose of this study is to introduce a simple experimental technique that allows for the online measure of language-induced activity in motor structures of the brain. This technique consists in the use of a grip force sensor that captures subtle grip force variations while participants listen to words and sentences. Since grip force reflects activity in motor brain structures, the continuous monitoring of force fluctuations provides a fine-grained estimation of motor activity across time. In other terms, this method allows for both localization of the source of language-induced activity to motor brain structures and high temporal resolution of the recorded data. To facilitate comparison of the data to be collected with this tool, we present two experiments that describe in detail the technical setup, the nature of the recorded data, and the analyses (including justification about the data filtering and artifact rejection) that we applied. We also discuss how the tool could be used in other domains of behavioral research.

  4. Cortical activation during power grip task with pneumatic pressure gauge: an fMRI study

    Science.gov (United States)

    Mohamad, M.; Mardan, N. H.; Ismail, S. S.

    2017-05-01

    Aging is associated with a decline in cognitive and motor function. But, the relationships with motor performance are less well understood. In this study, functional magnetic resonance imaging (fMRI) was used to assess cortical activation in older adults. This study employed power grip task that utilised block paradigm consisted of alternate 30s rest and active. A visual cue was used to pace the hand grip movement that clenched a cylindrical rubber bulb connected with pressure pneumatic gauge that measure the pressure (Psi). The objective of this study is determined the brain areas activated during motor task and the correlation between percentage signal change of each motor area (BA 4 and 6) and hand grip pressure. Result showed there was a significant difference in mean percentage signal change in BA 4 and BA 6 in both hemispheres and negative correlation obtained in BA 4 and BA 6. These results indicate that a reduced ability in the motor networks contribute to age-related decline in motor performance.

  5. The use of clamping grips and friction pads by tree frogs for climbing curved surfaces

    Science.gov (United States)

    Ji, Aihong; Yuan, Shanshan; Hill, Iain; Wang, Huan; Barnes, W. Jon P.; Dai, Zhendong; Sitti, Metin

    2017-01-01

    Most studies on the adhesive mechanisms of climbing animals have addressed attachment against flat surfaces, yet many animals can climb highly curved surfaces, like twigs and small branches. Here we investigated whether tree frogs use a clamping grip by recording the ground reaction forces on a cylindrical object with either a smooth or anti-adhesive, rough surface. Furthermore, we measured the contact area of fore and hindlimbs against differently sized transparent cylinders and the forces of individual pads and subarticular tubercles in restrained animals. Our study revealed that frogs use friction and normal forces of roughly a similar magnitude for holding on to cylindrical objects. When challenged with climbing a non-adhesive surface, the compressive forces between opposite legs nearly doubled, indicating a stronger clamping grip. In contrast to climbing flat surfaces, frogs increased the contact area on all limbs by engaging not just adhesive pads but also subarticular tubercles on curved surfaces. Our force measurements showed that tubercles can withstand larger shear stresses than pads. SEM images of tubercles revealed a similar structure to that of toe pads including the presence of nanopillars, though channels surrounding epithelial cells were less pronounced. The tubercles' smaller size, proximal location on the toes and shallow cells make them probably less prone to buckling and thus ideal for gripping curved surfaces. PMID:28228509

  6. On the Effect of Different Grips of Handsets on Data Rate in the Measured Channels

    Directory of Open Access Journals (Sweden)

    Maryam Rahimi

    2015-01-01

    Full Text Available The investigation on the achieved data rate of the cellular system considering different grips of handsets at different frequencies using measurement results of the measurement campaign—which was carried out in the city of Aalborg—is presented in this paper. The achieved data rate of the multiple-input single-output (MISO interference channel is investigated. A typical propagation environment using two BSs and four handsets, like smart phones, held by four to eight different users was designed and multiple-input multiple-output (MIMO channels in different scenarios were measured. In this paper, two BSs and two handsets at each measurement time are considered. The impact of the different parameters like correlation, different grips of handsets, and different long term evolution (LTE frequency bands on the achieved data rate is investigated for different measurements. It could be concluded that the variations in the values of data rate are weakly associated with the different grips of handsets but more correlated with different frequencies.

  7. Design and implementation of GRIP: a computerized glucose control system at a surgical intensive care unit

    Directory of Open Access Journals (Sweden)

    Zijlstra Felix

    2005-12-01

    Full Text Available Abstract Background Tight glucose control by intensive insulin therapy has become a key part of critical care and is an important field of study in acute coronary care. A balance has to be found between frequency of measurements and the risk of hypoglycemia. Current nurse-driven protocols are paper-based and, therefore, rely on simple rules. For safety and efficiency a computer decision support system that employs complex logic may be superior to paper protocols. Methods We designed and implemented GRIP, a stand-alone Java computer program. Our implementation of GRIP will be released as free software. Blood glucose values measured by a point-of-care analyzer were automatically retrieved from the central laboratory database. Additional clinical information was asked from the nurse and the program subsequently advised a new insulin pump rate and glucose sampling interval. Results Implementation of the computer program was uneventful and successful. GRIP treated 179 patients for a total of 957 patient-days. Severe hypoglycemia ( Conclusion A computer driven protocol is a safe and effective means of glucose control at a surgical ICU. Future improvements in the recommendation algorithm may further improve safety and efficiency.

  8. The Signs B [Image Omitted] and B-Bent [Image Omitted] in Israeli Sign Language According to the Theory of Phonology as Human Behavior

    Science.gov (United States)

    Fuks, Orit; Tobin, Yishai

    2008-01-01

    The purpose of the present research is to examine which of the two factors: (1) the iconic-semiotic factor; or (2) the human-phonetic factor is more relevant in explaining the appearance and distribution of the hand shape B-bent in Israeli Sign Language (ISL). The B-bent shape has been the subject of much attention in sign language research…

  9. Stress examination of flexor tendon pulley rupture in the crimp grip position: a 1.5-Tesla MRI cadaver study

    Energy Technology Data Exchange (ETDEWEB)

    Bayer, Thomas; Janka, Rolf [University of Erlangen-Nuremberg, Department of Radiology, Erlangen (Germany); Fries, Simon [Cantonal Hospital Lucerne, Orthopaedic Department, Wolhusen (Switzerland); Schweizer, Andreas [University of Zurich, Department of Orthopaedics, Balgrist, Zurich (Switzerland); Schoeffl, Isabelle [Klinikum Bamberg, Department of Pediatrics, Bamberg (Germany); Bongartz, Georg [University Basel, Department of Radiology, Basel (Switzerland)

    2015-01-15

    The objectives of this study were the evaluation of flexor tendon pulley rupture of the fingers in the crimp grip position using magnetic resonance imaging (MRI) and the comparison of the results with MRI in the neutral position in a cadaver study. MRI in the crimp grip position and in the neutral position was performed in 21 cadaver fingers with artificially created flexor tendon pulley tears (combined pulley rupture, n = 14; single pulley rupture, n = 7). Measurement of the distance between the tendon and bone was performed. Images were evaluated by two readers, first independently and in cases of discrepancy in consensus. Sensitivity and specificity for detecting combined pulley ruptures were calculated. Tendon bone distances were significantly higher in the crimp grip position than in the neutral position. Sensitivity and specificity for detecting combined pulley rupture were 92.86 % and 100 % respectively in the crimp grip position and 78.57 % and 85.71 % respectively in the neutral position. Kappa values for interobserver reliability were 0.87 in the crimp grip position and 0.59 in the neutral position. MRI examination in the crimp grip position results in higher tendon bone distances by subjecting the pulleys to a higher strain, which facilitates image evaluation with higher interobserver reliability, higher sensitivity, and higher specificity for combined pulley rupture compared with examination in the neutral position. (orig.)

  10. Attitude Strength.

    Science.gov (United States)

    Howe, Lauren C; Krosnick, Jon A

    2017-01-03

    Attitude strength has been the focus of a huge volume of research in psychology and related sciences for decades. The insights offered by this literature have tremendous value for understanding attitude functioning and structure and for the effective application of the attitude concept in applied settings. This is the first Annual Review of Psychology article on the topic, and it offers a review of theory and evidence regarding one of the most researched strength-related attitude features: attitude importance. Personal importance is attached to an attitude when the attitude is perceived to be relevant to self-interest, social identification with reference groups or reference individuals, and values. Attaching personal importance to an attitude causes crystallizing of attitudes (via enhanced resistance to change), effortful gathering and processing of relevant information, accumulation of a large store of well-organized relevant information in long-term memory, enhanced attitude extremity and accessibility, enhanced attitude impact on the regulation of interpersonal attraction, energizing of emotional reactions, and enhanced impact of attitudes on behavioral intentions and action. Thus, important attitudes are real and consequential psychological forces, and their study offers opportunities for addressing behavioral change.

  11. Bent and linear Uranium(IV) metallocenes with terminal and bridging cyanide ligands

    Energy Technology Data Exchange (ETDEWEB)

    Maynadie, J.; Berthet, J.C.; Thuery, P.; Ephritikhine, M. [CEA Saclay, DSM, DRECAM, Serv Chim Mol, Lab Claude Frejacques, CNRS URA 331, F-91191 Gif Sur Yvette, (France)

    2007-07-01

    Treatment of Cp{sub 2}{sup *}UI{sub 2} with KCN in thf led to the formation of Cp{sub 2}{sup *}U(CN){sub 2} (2), which further reacted with NR{sub 4}CN to give [Cp{sub 2}{sup *}U(CN){sub 3}][ NR{sub 4}] (R = Et, 3; R = {sup n}Bu, 3') and [Cp{sub 2}{sup *}U(CN){sub 5}][NR{sub 4}]{sub 3} (R = Et, 4; R {sup n}Bu, 4'). While the tri-cyanide 3' adopts the familiar bent sandwich configuration, the penta-cyanide 4 is, after the [Cp{sub 2}{sup *}U(NCMe){sub 5}]{sup 2+} cation, the second example of a linear metallocene resulting from complete saturation of the equatorial girdle. Compound 3' was also obtained by oxidation of the trivalent compound [Cp{sub 2}{sup *}U(CN){sub 3}][N{sup n}Bu{sub 4}]{sub 2}; the rapid and reversible electron transfer between the U(III) and U(IV) complexes was revealed by {sup 1}H NMR spectroscopy. The NMR spectra also revealed that 4 is partially dissociated in thf into 3, providing the first example of an equilibrating couple of bent and linear metallocenes [K = 4.24(4) * 10{sup -5} at 25 C, {delta}H = 199(6) kJ mol{sup -1}, and {delta}S = 586(20) J mol{sup -1} K{sup -1}]. The trinuclear compound [Cp{sub 2}{sup *}UCl{sub 2}({mu}-CN)]{sub 2}Mg(thf){sub 4} (1) and the 2D polymeric complex [Cp{sub 2}{sup *}U(dmf){sub 3}-({mu}-NC){sub 2}(AgI){sub 2}]{sub n} (5), which were obtained during initial attempts on the synthesis of 2-4 and uranium- (V) derivatives, exhibit a bent and linear sandwich structure, respectively. (authors)

  12. Lean mass, muscle strength and gene expression in community dwelling older men: findings from the Hertfordshire Sarcopenia Study (HSS).

    Science.gov (United States)

    Patel, Harnish P; Al-Shanti, Nasser; Davies, Lucy C; Barton, Sheila J; Grounds, Miranda D; Tellam, Ross L; Stewart, Claire E; Cooper, Cyrus; Sayer, Avan Aihie

    2014-10-01

    Sarcopenia is associated with adverse health outcomes. This study investigated whether skeletal muscle gene expression was associated with lean mass and grip strength in community-dwelling older men. Utilising a cross-sectional study design, lean muscle mass and grip strength were measured in 88 men aged 68-76 years. Expression profiles of 44 genes implicated in the cellular regulation of skeletal muscle were determined. Serum was analysed for circulating cytokines TNF (tumour necrosis factor), IL-6 (interleukin 6, IFNG (interferon gamma), IL1R1 (interleukin-1 receptor-1). Relationships between skeletal muscle gene expression, circulating cytokines, lean mass and grip strength were examined. Participant groups with higher and lower values of lean muscle mass (n = 18) and strength (n = 20) were used in the analysis of gene expression fold change. Expression of VDR (vitamin D receptor) [fold change (FC) 0.52, standard error for fold change (SE) ± 0.08, p = 0.01] and IFNG mRNA (FC 0.31; SE ± 0.19, p = 0.01) were lower in those with higher lean mass. Expression of IL-6 (FC 0.43; SE ± 0.13, p = 0.02), TNF (FC 0.52; SE ± 0.10, p = 0.02), IL1R1 (FC 0.63; SE ± 0.09, p = 0.04) and MSTN (myostatin) (FC 0.64; SE ± 0.11, p = 0.04) were lower in those with higher grip strength. No other significant changes were observed. Significant negative correlations between serum IL-6 (R = -0.29, p = 0.005), TNF (R = -0.24, p = 0.017) and grip strength were demonstrated. This novel skeletal muscle gene expression study carried out within a well-characterized epidemiological birth cohort has demonstrated that lower expression of VDR and IFNG is associated with higher lean mass, and lower expression of IL-6, TNF, IL1R1 and myostatin is associated with higher grip strength. These findings are consistent with a role of proinflammatory factors in mediating lower muscle strength in community-dwelling older men.

  13. Muscle strength in patients with acromegaly at diagnosis and during long-term follow-up.

    Science.gov (United States)

    Füchtbauer, Laila; Olsson, Daniel S; Bengtsson, Bengt-Åke; Norrman, Lise-Lott; Sunnerhagen, Katharina S; Johannsson, Gudmundur

    2017-08-01

    Patients with acromegaly have decreased body fat (BF) and increased extracellular water (ECW) and muscle mass. Although there is a lack of systematic studies on muscle function, it is believed that patients with acromegaly may suffer from proximal muscle weakness despite their increased muscle mass. We studied body composition and muscle function in untreated acromegaly and after biochemical remission. Prospective observational study. Patients with acromegaly underwent measurements of muscle strength (dynamometers) and body composition (four-compartment model) at diagnosis (n = 48), 1 year after surgery (n = 29) and after long-term follow-up (median 11 years) (n = 24). Results were compared to healthy subjects. Untreated patients had increased body cell mass (113 ± 9% of predicted) and ECW (110 ± 20%) and decreased BF (67 ± 7.6%). At one-year follow-up, serum concentration of IGF-I was reduced and body composition had normalized. At baseline, isometric muscle strength in knee flexors and extensors was normal and concentric strength was modestly increased whereas grip strength and endurance was reduced. After one year, muscle strength was normal in both patients with still active disease and patients in remission. At long-term follow-up, all patients were in remission. Most muscle function tests remained normal, but isometric flexion and the fatigue index were increased to 153 ± 42% and 139 ± 28% of predicted values, respectively. Patients with untreated acromegaly had increased body cell mass and normal or modestly increased proximal muscle strength, whereas their grip strength was reduced. After biochemical improvement and remission, body composition was normalized, hand grip strength was increased, whereas proximal muscle fatigue increased. © 2017 European Society of Endocrinology.

  14. CRYSTAL simulation code and modeling of coherent effects in a bent crystal at the LHC

    Energy Technology Data Exchange (ETDEWEB)

    Sytov, A.I., E-mail: alex_sytov@mail.ru [Research Institute for Nuclear Problems, Belarusian State University, Bobruiskaya str., 11, 220030 Minsk (Belarus); INFN Sezione di Ferrara, Dipartimento di Fisica e Scienze della Terra, Università di Ferrara, Via Saragat 1, 44100 Ferrara (Italy); Tikhomirov, V.V., E-mail: vvtikh@mail.ru [Research Institute for Nuclear Problems, Belarusian State University, Bobruiskaya str., 11, 220030 Minsk (Belarus)

    2015-07-15

    A CRYSTAL simulation code for particle tracking in crystals is introduced. Its essence consists in both adequate and fast sampling of proton trajectories in crystals which is crucial for both correct description of experiments and quantitative prediction of new effects. The H8 single-pass experiment at the CERN SPS as well as 7 TeV proton deflection by a bent crystal at the LHC are simulated. We predict the existence of dechanneling peaks corresponding to the planar channeling oscillations as well as describe the possibility of their observation at high energies, specifically at the LHC energy. An effect of excess over the amorphous level of ionization losses in the channeling mode was also found at 7 TeV.

  15. The fourth Bent-toed Gecko of the genus Cyrtodactylus (Squamata: Gekkonidae) from Java, Indonesia.

    Science.gov (United States)

    Riyanto, Awal; Grismer, L Lee; Wood, Perry L

    2015-12-22

    Cyrtodactylus petani sp. nov. is a new species of Bent-toed Gecko from Java, Indonesia that had been masquerading under the name C. fumosus (Müller, 1895). The new species is differentiated from C. fumosus and all its Sundaland congeners by having the following combination of morphological characters: a maximum SVL of 57.2 mm; nine or ten supralabials; seven or eight infralabials; strongly tuberculate body and limbs; 20-25 paravertebral tubercles; 30-35 ventral scales; enlarged precloacal scales; enlarged femoral scales; 17-18 subdigital lamellae on the fourth toe; 31-35 continuous precloacal and femoral pores in males, pores absent in females; no precloacal groove; no enlarged median subcaudals; tubercles on anterior portion of tail; no reticulated pattern on top of head; a blotched dorsal pattern; and no paired, dark, semi-lunar shaped blotches on the nape.

  16. Standing helicon induced by a rapidly bent magnetic field in plasmas

    Science.gov (United States)

    Takahashi, Kazunori; Takayama, Sho; Komuro, Atsushi; Ando, Akira; Plasma physics Team

    2016-09-01

    An electron energy probability function and an rf magnetic field are measured in an rf hydrogen helicon source, where axial and transverse static magnetic fields are applied to the source by solenoids and to the diffusion chamber by filter magnets, respectively. It is demonstrated that the helicon wave is reflected by the rapidly bent magnetic field and the resultant standing wave heats the electrons between the source and the magnetic filter, while the electron cooling effect by the magnetic filter is maintained. It is interpreted that the standing wave is generated by the presence of spatially localized change of a refractive index. The application to the hydrogen negative ion source used for the neutral beam injection system for fusion plasma heating is discussed. This work is partially supported by grant-in-aid for scientific research (16H04084 and 26247096) from the Japan Society for the Promotion of Science.

  17. Energy loss distributions of 7 TeV protons channeled in a bent silicon crystals

    Directory of Open Access Journals (Sweden)

    Stojanov Nace

    2013-01-01

    Full Text Available The energy loss distributions of relativistic protons axially channeled through the bent Si crystals, with the constant curvature radius, R = 50 m, are studied here. The proton energy is 7 TeV and the thickness of the crystal is varied from 1 mm to 5 mm, which corresponds to the reduced crystal thickness, L, from 2.1 to 10.6, respectively. The proton energy was chosen in accordance with the large hadron collider project, at the European Organization for Nuclear Research, in Geneva, Switzerland. The energy loss distributions of the channeled protons were generated by the computer simulation method using the numerical solution of the proton equations of motion in the transverse plane. Dispersion of the proton scattering angle caused by its collisions with the crystal’s electrons was taken into account. [Projekat Ministarstva nauke Republike Srbije, br. III 45006

  18. Channeling, volume reflection, and volume capture study of electrons in a bent silicon crystal

    Science.gov (United States)

    Wistisen, T. N.; Uggerhøj, U. I.; Wienands, U.; Markiewicz, T. W.; Noble, R. J.; Benson, B. C.; Smith, T.; Bagli, E.; Bandiera, L.; Germogli, G.; Guidi, V.; Mazzolari, A.; Holtzapple, R.; Tucker, S.

    2016-07-01

    We present the experimental data and analysis of experiments conducted at SLAC National Accelerator Laboratory investigating the processes of channeling, volume-reflection and volume-capture along the (111) plane in a strongly bent quasimosaic silicon crystal. These phenomena were investigated at 5 energies: 3.35, 4.2, 6.3, 10.5, and 14.0 GeV with a crystal with bending radius of 0.15 m, corresponding to curvatures of 0.053, 0.066, 0.099, 0.16, and 0.22 times the critical curvature, respectively. Based on the parameters of fitting functions we have extracted important parameters describing the channeling process such as the dechanneling length, the angle of volume reflection, the surface transmission, and the widths of the distribution of channeled particles parallel and orthogonal to the plane.

  19. Splitting of a high-energy positively-charged particle beam with a bent crystal

    Science.gov (United States)

    Bandiera, L.; Kirillin, I. V.; Bagli, E.; Berra, A.; De Salvador, D.; Guidi, V.; Lietti, D.; Mazzolari, A.; Prest, M.; Shul'ga, N. F.; Sytov, A.; Vallazza, E.

    2017-07-01

    The possibility of high-energy positively-charged particle beam splitting by means of a short bent axially oriented silicon crystal was recently reported in an experiment carried out at CERN SPS H8 extracted line with a 400 GeV/c proton beam. Here, we investigate more deeply such a possibility focusing our attention on the efficiency of beam splitting and its modulation for different crystal-to-beam orientations. New experimental results confirm the possibility of modulating the 400 GeV/c proton beam intensity in different planar channels by adjusting the orientation of the crystal. Furthermore, an analysis of the beam splitting efficiency vs. the curvature of the crystal was carried out through simulation, highlighting that there exists a bending radius for which the efficiency is maximal.

  20. Two-state model for nematic liquid crystals made of bent-core molecules

    Science.gov (United States)

    Madhusudana, N. V.

    2017-08-01

    Nematic (N ) liquid crystals made of bent-core molecules exhibit unusual physical properties such as an intermediate phase between the N and isotropic (I ) phases, a very weak N I transition as inferred from magnetic birefringence measurements in a low field, which is apparently incompatible with a large shift in the N I transition temperature (Tn i) measured under a high field. Using our conformational studies on the aromatic cores, we propose that only conformers which are more straightened than those in the ground state (GS) form clusters with a few layers, which persist even in the isotropic phase, as inferred from x-ray and rheological experiments. We present a Landau-de Gennes theory of the medium, including an orientational coupling between the clusters and the GS molecules, which accounts for all the unusual properties. The intermediate phase to isotropic transition is predicted to exhibit critical behavior at a very low magnetic field of <1 kG .

  1. CRYSTAL simulation code and modeling of coherent effects in a bent crystal at the LHC

    Science.gov (United States)

    Sytov, A. I.; Tikhomirov, V. V.

    2015-07-01

    A CRYSTAL simulation code for particle tracking in crystals is introduced. Its essence consists in both adequate and fast sampling of proton trajectories in crystals which is crucial for both correct description of experiments and quantitative prediction of new effects. The H8 single-pass experiment at the CERN SPS as well as 7 TeV proton deflection by a bent crystal at the LHC are simulated. We predict the existence of dechanneling peaks corresponding to the planar channeling oscillations as well as describe the possibility of their observation at high energies, specifically at the LHC energy. An effect of excess over the amorphous level of ionization losses in the channeling mode was also found at 7 TeV.

  2. Bent bone dysplasia (BBD)-FGFR2 type: the radiologic manifestations in early gestation

    Energy Technology Data Exchange (ETDEWEB)

    Handa, Atsuhiko; Okajima, Yuka; Kurihara, Yasuyuki [St. Luke' s International Hospital, Department of Radiology, Tokyo (Japan); Izumi, Noriko; Yamanaka, Michiko [St. Luke' s International Hospital, Department of Integrated Women' s Health, Tokyo (Japan)

    2016-02-15

    Bent bone dysplasia-fibroblast growth factor receptor 2 type (BBD-FGFR2) is a recently identified skeletal dysplasia caused by specific FGFR2 mutations, characterized by craniosynostosis and prenatal bowing of the long bones. Only a few cases have been published. We report an affected fetus terminated at 21 weeks of gestation. The clinical and radiologic manifestations mostly recapitulate previous descriptions; however we suggest additional hallmarks of this disorder in early gestation. These hallmarks include distinctive short, thick clavicles and wavy ribs, as well as vertebral bodies that showed striking anteroposterior shortening. Femoral fractures were also present in our case. Although craniosynostosis is a hallmark of the disease, clinicians should be aware that craniosynostosis might not be readily apparent on plain films early in gestation. (orig.)

  3. Performance of bent-crystal x-ray microscopes for high energy density physics research.

    Science.gov (United States)

    Schollmeier, Marius S; Geissel, Matthias; Shores, Jonathon E; Smith, Ian C; Porter, John L

    2015-06-01

    We present calculations for the field of view (FOV), image fluence, image monochromaticity, spectral acceptance, and image aberrations for spherical crystal microscopes, which are used as self-emission imaging or backlighter systems at large-scale high energy density physics facilities. Our analytic results are benchmarked with ray-tracing calculations as well as with experimental measurements from the 6.151 keV backlighter system at Sandia National Laboratories. The analytic expressions can be used for x-ray source positions anywhere between the Rowland circle and object plane. This enables quick optimization of the performance of proposed but untested, bent-crystal microscope systems to find the best compromise between FOV, image fluence, and spatial resolution for a particular application.

  4. Theoretical study of bifurcated bent blue-shifted hydrogen bonds CH2…Y

    Institute of Scientific and Technical Information of China (English)

    LI AnYong

    2008-01-01

    Ab initio quantum chemistry methods were applied to study the bifurcated bent hydrogen bonds Y… MP2/6-311++G(2df,2p) levels. The results show that in each complex there are two equivalent natural bond orbital analysis shows that these blue-shifted H-bonds are caused by three factors: large rehybridization; small direct intermolecular hyperconjugation and larger indirect intermolecular hy-perconjugation; large decrease of intramolecular hyperconjugation. The topological analysis of elec-tron density shows that in each complex there are three intermolecular critical points: there is one bond critical point between the acceptor atom Y and each hydrogen, and there is a ring critical point inside the tetragon YHCH, so these interactions are exactly H-bonding.

  5. Elliptically-bent crystal spectrograph for X-ray diagnosis of laser-produced plasmas

    Institute of Scientific and Technical Information of China (English)

    Xiancai Xiong(熊先才); Xianxin Zhong(钟先信); Shali Xiao(肖沙里); Guohong Yang(杨国洪); Jie Gao(高洁)

    2004-01-01

    In order to measure spatially and temporarily resolved laser-produced plasma X-ray spectra in 0.2 - 2nm region, a novel two-channel elliptically-bent crystal spectrograph has been developed. Dispersive elements are LiF, PET, Mica, and KAP crystals, which cover Bragg angles in the range of 30 - 67.5degrees. Eccentricity and focal distance of twin ellipses are 0.9586 and 1350 mm, respectively. Spatially resolved spectrum is photographically recorded with an X-ray film or X-CCD camera in one channel, and temporarily resolved one is photographically recorded with an X-ray streak camera in another channel,thus spatially and temporarily resolved spectra can be simultaneously obtained. Spectral images were acquired with X-CCD and PET in SHENGUANG-Ⅱ laser facility, and experimental results show that the spectral resolution of the spectrograph is about 0.002 nm.

  6. Silky bent grass resistance to herbicides: one year of monitoring in Belgium.

    Science.gov (United States)

    Henriet, F; Bodson, B; Morales, R Meza

    2013-01-01

    Silky bent grass (Apera spica-venti (L.) P. Beauv.) is a common weed of cereal crops widely spread in Northern and Easthern Europe (Germany, Czech Republic,...), Northern Asia, Siberia and Canada. Up to now, no resistant case has been detected in Belgium but some chemical weeding failures have been observed in Wallonia fields. During summer 2011, 37 seed samples of Apera spica-venti were collected in Wallonia and submitted to resistance tests in controlled conditions. Three modes of action were tested: acetyl coenzyme-A carboxylase inhibitors (pinoxaden and cycloxydim), acetolactate synthase inhibitors (mesosulfuron+iodosulfu-ron, pyroxsulam and sulfometuron) and photosynthesis inhibitors (isoproturon). One susceptible standard population was included in the test in order to validate it and to permit wild populations classification according to "R" rating system developed by Moss et al (2007). Most of populations were susceptible but some populations showed resistance to at least one of the three tested modes of action.

  7. Radiation from multi-GeV electrons and positrons in periodically bent silicon crystal

    CERN Document Server

    Bezchastnov, Victor G; Solovyov, Andrey V

    2015-01-01

    A periodically bent Si crystal is shown to efficiently serve for producing highly monochromatic radiation in a gamma-ray energy spectral range. A short-period small-amplitude bending yields narrow undulator-type spectral peaks in radiation from multi-GeV electrons and positrons channeling through the crystal. Benchmark theoretical results on the undulator are obtained by simulations of the channeling with a full atomistic approach to the projectile-crystal interactions over the macroscopic propagation distances. The simulations are facilitated by employing the MBN Explorer package for molecular dynamics calculations on the meso- bio- and nano-scales. The radiation from the ultra-relativistic channeling projectiles is computed within the quasi-classical formalism. The effects due to the quantum recoil are shown to be significantly prominent in the gamma-ray undulator radiation.

  8. 更多新惊喜——访Hegel总裁Bent Holter

    Institute of Scientific and Technical Information of China (English)

    沈剑萍

    2010-01-01

    这已经是Bent Holter(以下简作Bent)第四次到广州了。Bent这次显得特别高兴,因为Hegel的产品目前在中国拥有很高的知名度,销售业绩也达到了一个崭新的高度。笔者(以下简作“沈”)知道Bent一向有许多新的刨意,Hegel推出新产品的速度也很快,所以第一时间想知道他又绐国内的发烧友带来什么新的惊喜。

  9. Bent Shaped 1,3,4-Oxadiazole/Thiadiazole heterocyclic rings containing liquid crystals

    Indian Academy of Sciences (India)

    Chinnaiyan Selvarasu; Palaninathan Kannan

    2015-10-01

    Two series of bent shaped 1,3,4-oxadiazole/thiadiazole heterocyclic ring containing liquid crystalline (LC) compounds were synthesized and characterized by FT-IR, 1H, 13C-NMR and ESI-Mass spectro-scopic techniques. Liquid crystal properties were investigated by polarized optical microscopy and differential scanning calorimetry. All the compounds exhibited mesophases such as nematic, smectic A and smectic C phases. The liquid crystalline effects were ascertained by changing the central atom in the heterocyclic ring and by increasing the length of the terminal alkyloxy chains which bring considerable improvements on the mesomorphic properties. The absorption and emission spectral studies of all the compounds were investigated and confirmed.

  10. Polar order in columnar phase made of polycatenar bent-core molecules.

    Science.gov (United States)

    Gorecka, Ewa; Pociecha, Damian; Matraszek, Joanna; Mieczkowski, Jozef; Shimbo, Yoshio; Takanishi, Yoichi; Takezoe, Hideo

    2006-03-01

    Columnar phases made of polycatenar molecules with bent-shaped mesogenic cores are studied. The polar order in this system is associated with the change of the column building blocks from flat disks (Colh phase) into cones (Colh PA phase), which allows for axial polarization of the columns. The nature of the Colh and Colh PA phase transition changes from first order for short homologues to continuous for the longest one. This can be attributed to decreasing intercolumnar interactions due to broadening of the columnar scaffold made of partially melted terminal alkyl chains. Decrease of intercolumnar interactions is also responsible for a strong increase of the pretransitional fluctuations in the Colh phase. The mesophase observed for the longest homologues is reminiscent of the relaxor phase observed for solid crystals.

  11. Crosstalk analysis in homogeneous multi-core two-mode fiber under bent condition.

    Science.gov (United States)

    Chang, J H; Choi, H G; Bae, S H; Sim, D H; Kim, Hoon; Chung, Y C

    2015-04-20

    We analyze the inter-core crosstalk in homogeneous multi-core two-mode fibers (MC-TMFs) under bent condition by using the coupled-mode equations. In particular, we investigate the effects of the intra-core mode coupling on the inter-core crosstalk for two different types of MC-TMFs at various bending radii. The results show that the inter-core homo-mode crosstalk of LP(11) mode is dominant under the gentle fiber bending condition due to its large effective area. However, as the fiber bending becomes tight, the intra-core mode coupling is significantly enhanced and consequently makes all the inter-core crosstalk levels comparable to each other regardless of the mode. A similar tendency is observed at a reduced bending radius when the difference in the propagation constants between modes is large and core pitch is small.

  12. arXiv Feasibility of measuring the magnetic dipole moments of the charm baryons at the LHC using bent crystals

    CERN Document Server

    Bezshyyko, O.A.; Fomin, A.S.; Fomin, S.P.; Kirillin, I.V.; Korchin, A. Yu.; Massacrier, L.; Natochii, A.; Robbe, P.; Scandale, W.; Shul'ga, N.F.; Stocchi, A.

    2017-08-28

    In this paper we revisit the idea of measuring the magnetic dipole moments of the charm baryons and, in particular, of charmed Lambda by studying the spin precession induced by the strong effective magnetic field inside the channels of a bent crystal. We present a detailed sensitivity study showing the feasibility of such an experiment at the LHC in the coming years.

  13. Specific distribution behavior of a ternary mixture of solvents fed into bent and wound microchannels in microchips.

    Science.gov (United States)

    Nishiyama, Kei; Murata, Masaharu; Hashimoto, Masahiko; Tsukagoshi, Kazuhiko

    2013-01-01

    The tube radial distribution of ternary solvents (water-hydrophilic/hydrophobic organic mixture) fed into bent and wound microchannels in a microchip was examined by fluorescence observations of dyes dissolved in the solvents under laminar flow conditions. Four kinds of microchips incorporating bent microchannels were used, together with a microchip with a straight channel. The microchannels had different bending times (2, 4, or 12 times), bending radii (0.8, 2.3, or 3 mm), and total channel lengths (80, 120, 200, or 500 mm). A water-acetonitrile (hydrophilic)-ethyl acetate (hydrophobic) mixture containing relatively hydrophilic Eosin Y (green) and hydrophobic perylene (blue) was delivered into the bent microchannels in the microchips. The fluorescence of the green and blue dyes enabled us to observe the specific radial distribution behavior of the ternary solvents in the bent micro channels at 0°C, including liquid-liquid interfaces. Further, the radial distribution pattern of the solvents was clearly observed in the wound microchannel (bending radius, ca. 0.1 mm; real total channel length, 500 mm; and apparent straight channel length, 40 mm) at 20°C (room temperature) as well as 0°C. It was found that the radial distribution behaviors of the solvents were successfully generated in even specific microchannels including various types of curves under the present conditions.

  14. Surface plasmon polariton propagation along a 90 degrees bent line defect in a periodically corrugated metal surface

    DEFF Research Database (Denmark)

    Bozhevolnyi, S.I.; Volkov, V.S.; Leosson, Kristjan

    2001-01-01

    Propagation of surface plasmon polaritons (SPPs) excited in the wavelength range of 720-860 nm at a gold (45-nm-thick) film surface with lithographically fabricated (170-nm-wide and 50-nm-high) scatterers arranged in a 400-nm-period triangular lattice containing a 90 degrees bent line defect...

  15. Monte Carlo N-Particle Tracking of Ultrafine Particle Flow in Bent Micro-Tubes

    Energy Technology Data Exchange (ETDEWEB)

    Casella, Andrew M.; Loyalka, Sudarsham K.

    2016-02-16

    The problem of large pressure-differential driven laminar convective-diffusive ultrafine aerosol flow through bent micro-tubes is of interest in several contemporary research areas including; release of contents from pressurized containment vessels, aerosol sampling equipment, advanced scientific instruments, gas-phase micro-heat exchangers, and microfluidic devices. In each of these areas, the predominant problem is the determination of the fraction of particles entering the micro-tube that is deposited within the tube and the fraction that is transmitted through. Due to the extensive parameter restrictions of this class of problems, a Lagrangian particle tracking method making use of the coupling of the analytical stream line solutions of Dean and the simplified Langevin equation is quite a useful tool in problem characterization. This method is a direct analog to the Monte Carlo N-Particle method of particle transport extensively used in nuclear physics and engineering. In this work, 10 nm diameter particles with a density of 1 g/cm3 are tracked within micro-tubes with toroidal bends with pressure differentials ranging between 0.2175 and 0.87 atmospheres. The tubes have radii of 25 microns and 50 microns and the radius of curvature is between 1 m and 0.3183 cm. The carrier gas is helium, and temperatures of 298 K and 558 K are considered. Numerical convergence is considered as a function of time step size and of the number of particles per simulation. Particle transmission rates and deposition patterns within the bent micro-tubes are calculated.

  16. Energy loss distributions of 7 TeV protons axially channeled in the bent Si crystal

    Science.gov (United States)

    Stojanov, Nace; Petrović, Srdjan

    2016-04-01

    In this article, the energy loss distributions of relativistic protons axially channeled in the bent Si crystal are studied. The crystal thickness is equal to 1 mm, which corresponds to the reduced crystal thickness, Λ, equal to 1.22, whereas the bending angle, α, was varied from 0 to 30 μrad. The proton energy of 7 TeV was chosen in accordance with the concept of using the bent crystals as a tool for selective deflection of the beam halo particles from the LUA9 experiment at LHC. For the continuum interaction potential of the proton and the crystal the Molière's expression was used and the energy loss of a proton was calculated by applying the trajectory dependent stopping power model. Further, the uncertainness of the scattering angle of the proton caused by its collisions with the electrons of the crystal and the divergence of the proton beam were taken into account. The energy loss distribution of the channeled protons was obtained via the numerical solution of the proton equations of motion in the transverse plane and the computer simulation method. The analysis of the obtained theoretical data shows that the shape of the energy loss distribution strongly depends on the horizontal or vertical direction of the curvature of the crystal. The number of dechanneled protons as a function of the bending angle also strongly depends on the direction of the crystal's curvature. As a result, the dechanneling rates and ranges, obtained from the Gompertz type sigmoidal fitting functions, have different sets of values for different bending orientations. We have also studied the influence of the proton beam divergence on the energy loss distribution of channeled protons.

  17. Corresponding-states behavior of SPC/E-based modified (bent and hybrid) water models

    Science.gov (United States)

    Weiss, Volker C.

    2017-02-01

    The remarkable and sometimes anomalous properties of water can be traced back at the molecular level to the tetrahedral coordination of molecules due to the ability of a water molecule to form four hydrogen bonds to its neighbors; this feature allows for the formation of a network that greatly influences the thermodynamic behavior. Computer simulations are becoming increasingly important for our understanding of water. Molecular models of water, such as SPC/E, are needed for this purpose, and they have proved to capture many important features of real water. Modifications of the SPC/E model have been proposed, some changing the H-O-H angle (bent models) and others increasing the importance of dispersion interactions (hybrid models), to study the structural features that set water apart from other polar fluids and from simple fluids such as argon. Here, we focus on the properties at liquid-vapor equilibrium and study the coexistence curve, the interfacial tension, and the vapor pressure in a corresponding-states approach. In particular, we calculate Guggenheim's ratio for the reduced apparent enthalpy of vaporization and Guldberg's ratio for the reduced normal boiling point. This analysis offers additional insight from a more macroscopic, thermodynamic perspective and augments that which has already been learned at the molecular level from simulations. In the hybrid models, the relative importance of dispersion interactions is increased, which turns the modified water into a Lennard-Jones-like fluid. Consequently, in a corresponding-states framework, the typical behavior of simple fluids, such as argon, is seen to be approached asymptotically. For the bent models, decreasing the bond angle turns the model essentially into a polar diatomic fluid in which the particles form linear molecular arrangements; as a consequence, characteristic features of the corresponding-states behavior of hydrogen halides emerge.

  18. Functional corticospinal projections from human supplementary motor area revealed by corticomuscular coherence during precise grip force control.

    Directory of Open Access Journals (Sweden)

    Sophie Chen

    Full Text Available The purpose of the present study was to investigate whether corticospinal projections from human supplementary motor area (SMA are functional during precise force control with the precision grip (thumb-index opposition. Since beta band corticomuscular coherence (CMC is well-accepted to reflect efferent corticospinal transmission, we analyzed the beta band CMC obtained with simultaneous recording of electroencephalographic (EEG and electromyographic (EMG signals. Subjects performed a bimanual precise visuomotor force tracking task by applying isometric low grip forces with their right hand precision grip on a custom device with strain gauges. Concurrently, they held the device with their left hand precision grip, producing similar grip forces but without any precision constraints, to relieve the right hand. Some subjects also participated in a unimanual control condition in which they performed the task with only the right hand precision grip while the device was held by a mechanical grip. We analyzed whole scalp topographies of beta band CMC between 64 EEG channels and 4 EMG intrinsic hand muscles, 2 for each hand. To compare the different topographies, we performed non-parametric statistical tests based on spatio-spectral clustering. For the right hand, we obtained significant beta band CMC over the contralateral M1 region as well as over the SMA region during static force contraction periods. For the left hand, however, beta band CMC was only found over the contralateral M1. By comparing unimanual and bimanual conditions for right hand muscles, no significant difference was found on beta band CMC over M1 and SMA. We conclude that the beta band CMC found over SMA for right hand muscles results from the precision constraints and not from the bimanual aspect of the task. The result of the present study strongly suggests that the corticospinal projections from human SMA become functional when high precision force control is required.

  19. Age-related changes in muscle strength and spinal kyphosis angles in an elderly Japanese population.

    Science.gov (United States)

    Kasukawa, Yuji; Miyakoshi, Naohisa; Hongo, Michio; Ishikawa, Yoshinori; Kudo, Daisuke; Suzuki, Masazumi; Mizutani, Takashi; Kimura, Ryouta; Ono, Yuichi; Shimada, Yoichi

    2017-01-01

    Lumbar kyphosis and the decreased mobility of the lumbar spine increase the risk of falls and impair both the quality of life and the ability to perform activities of daily living. However, in the elderly Japanese population, little is known about the age-related changes and sex-related differences in muscle strength, including of the upper and lower extremities and back extensors. An adequate kyphotic or lordotic angle has also not been determined. In this study, we evaluated the age-related changes in muscle strength and spinal kyphosis in 252 males and 320 females ≥50 years of age. Grip, back extensor, hip flexor, and knee extensor strength; thoracic and lumbar kyphosis; and spinal inclination in the neutral standing position were assessed, together with the range of motion of the thoracic and lumbar spine and spinal inclination. Grip strength, back extensor strength, and the strength of the hip flexors and knee extensors decreased significantly with aging, both in males (Pstrength and the thoracic kyphosis angle were significant variables influencing the lumbar kyphosis angle in both sexes. Spinal inclination correlated significantly with both the lumbar kyphosis angle and hip flexor strength in males, as well as with the lumbar kyphosis angle in females.

  20. Standing balance and strength measurements in older adults living in residential care communities.

    Science.gov (United States)

    Alqahtani, Bader A; Ferchak, Mary Ann; Huppert, Theodore J; Sejdic, Ervin; Perera, Subashan; Greenspan, Susan L; Sparto, Patrick J

    2016-12-20

    Research on balance and mobility in older adults has been conducted primarily in lab-based settings in individuals who live in the community. Although they are at greater risk of falls, residents of long-term care facilities, specifically residential care communities (RCCs), have been investigated much less frequently. We sought to determine the feasibility of using portable technology-based measures of balance and muscle strength (i.e., an accelerometer and a load cell) that can be used in any RCC facility. Twenty-nine subjects (age 87 ± 6 years) living in RCCs participated. An accelerometer placed on the back of the subjects measured body sway during different standing conditions. Sway in antero-posterior and mediolateral directions was calculated. Lower extremity strength was measured with a portable load cell and the within-visit reliability was determined. Assessments of grip strength, gait speed, frailty, and comorbidity were also examined. A significant increase in postural sway in both the AP and ML directions occurred as the balance conditions became more difficult due to alteration of sensory feedback (p strength measurements were highly reliable (ICC = 0.93-0.99). An increase in lower extremity strength was associated with increased grip strength and gait speed. The portable instruments provide inexpensive ways for measuring balance and strength in the understudied RCC population, but additional studies are needed to examine their relationship with functional outcomes.

  1. Scale effects on the transverse tensile strength of graphite epoxy composites

    Science.gov (United States)

    Obrien, T. Kevin; Salpekar, Satish A.

    1992-01-01

    The influence of material volume on the transverse tensile strength of AS4/3501-6 graphite epoxy composites was investigated. Tensile tests of 90 degree laminates with 3 different widths and 5 different thicknesses were conducted. A finite element analysis was performed to determine the influence of the grip on the stress distribution in the coupons and explain the tendency for the distribution of failure locations to be skewed toward the grip. Specimens were instrumented with strain gages and extensometers to insure good alignment and to measure failure strains. Data indicated that matrix dominated strength properties varied with the volume of material that was stressed, with the strength decreasing as volume increased. Transverse strength data were used in a volumetric scaling law based on Weibull statistics to predict the strength of 90 degree laminates loaded in three point bending. Comparisons were also made between transverse strength measurements and out-of-plane interlaminar tensile strength measurements from curved beam bending tests. The significance of observed scale effects on the use of tests for material screening, quality assurance, and design allowables is discussed.

  2. A regime map for secondary flow structures under physiological and multi-harmonic inflow through a bent tube model for curved arteries

    Science.gov (United States)

    Callahan, Shannon M.; Caldwell, Kirin; Bulusu, Kartik V.; Plesniak, Michael W.

    2012-11-01

    Secondary flow structures are known to affect wall shear stress, which is closely related to atherogenesis and drug particle deposition. A regime map provides a framework to examine phase-wise variations in secondary flow structures under physiological and multi-harmonic inflow waveforms under conditions of a fixed Womersley number (4.2) and curvature ratio (1/7). Experimental PIV data were acquired at the 90-degree location in a 180-degree curved test section of a bent tube model for curved arteries using a blood analog working fluid. Coherent structure detection was performed using a continuous wavelet transform algorithm (PIVlet 1.2) and further analysis was carried out by grouping similar secondary flow structures at a fixed secondary Reynolds numbers. Phase-locked, planar vorticity fields over one period of inflow waveform revealed size, structure and strength similarities in secondary flow morphologies during the acceleration and deceleration phases. The utility of the new regime map lies in the a priori identification of pulsatile secondary flow structures, eliminating the need for exhaustive experimentation or computing, requiring only flow rate measurements that are easily acquired under clinical conditions. Supported by the National Science Foundation, Grant No. CBET-0828903 and GW Center for Biomimetics and Bioinspired Engineering (COBRE).

  3. Secondary flow structures in the presence of Type-IV stent fractures through a bent tube model for curved arteries: Effect of circulation thresholding

    Science.gov (United States)

    Hussain, Shadman; Bulusu, Kartik V.; Plesniak, Michael W.

    2013-11-01

    A common treatment for atherosclerosis is the opening of narrowed arteries resulting from obstructive lesions by angioplasty and stent implantation to restore unrestricted blood flow. ``Type-IV'' stent fractures involve complete transverse, linear fracture of stent struts, along with displacement of the stent fragments. Experimental data pertaining to secondary flows in the presence of stents that underwent ``Type-IV'' fractures in a bent artery model under physiological inflow conditions were obtained through a two-component, two-dimensional (2C-2D) PIV technique. Concomitant stent-induced flow perturbations result in secondary flow structures with complex, multi-scale morphologies and varying size-strength characteristics. Ultimately, these flow structures may have a role to play in restenosis and progression of atherosclerotic plaque. Vortex circulation thresholds were established with the goal of resolving and tracking iso-circulation secondary flow vortical structures and their morphological changes. This allowed for a parametric evaluation and quantitative representation of secondary flow structures undergoing deformation and spatial reorganization. Supported by NSF Grant No. CBET- 0828903 and GW Center for Biomimetics and Bioinspired Engineering.

  4. Quantification of hand and forearm muscle forces during a maximal power grip task.

    Science.gov (United States)

    Goislard de Monsabert, Benjamin; Rossi, Jérémy; Berton, Eric; Vigouroux, Laurent

    2012-10-01

    The aim of this study was to estimate muscle and joint forces during a power grip task. Considering the actual lack of quantification of such internal variables, this information would be essential for sports sciences, medicine, and ergonomics. This study also contributed to the advancement of scientific knowledge concerning hand control during power grip. A specially designed apparatus combining both an instrumented handle and a pressure map was used to record the forces at the hand/handle interface during maximal exertions. Data were processed such that the forces exerted on 25 hand anatomical areas were determined. Joint angles of the five fingers and the wrist were also computed from synchronized kinematic measurements. These processed data were used as input of a hand/wrist biomechanical model, which includes 23 degrees of freedom and 42 muscles to estimate muscle and joint forces. Greater forces were applied on the distal phalanges of the long fingers compared with the middle and the proximal ones. Concomitantly, high solicitations were observed for FDP muscles. A large cocontraction level of extensor muscles was also estimated by the model and confirmed previously reported activities and injuries of extensor muscles related to the power grip. Quantifying hand internal loadings also resulted in new insights into the thumb and the wrist biomechanics. Output muscle tension ratios were all in smaller ranges than the ones reported in the literature. Including wrist and finger interactions in this hand model provided new quantification of muscle load sharing, cocontraction level, and biomechanics of the hand. Such information could complete future investigations concerning handle ergonomics or pathomechanisms of hand musculoskeletal disorders.

  5. The impact of unilateral brain damage on anticipatory grip force scaling when lifting everyday objects.

    Science.gov (United States)

    Eidenmüller, S; Randerath, J; Goldenberg, G; Li, Y; Hermsdörfer, J

    2014-08-01

    The scaling of our finger forces according to the properties of manipulated objects is an elementary prerequisite of skilled motor behavior. Lesions of the motor-dominant left brain may impair several aspects of motor planning. For example, limb-apraxia, a tool-use disorder after left brain damage is thought to be caused by deficient recall or integration of tool-use knowledge into an action plan. The aim of the present study was to investigate whether left brain damage affects anticipatory force scaling when lifting everyday objects. We examined 26 stroke patients with unilateral brain damage (16 with left brain damage, ten with right brain damage) and 21 healthy control subjects. Limb apraxia was assessed by testing pantomime of familiar tool-use and imitation of meaningless hand postures. Participants grasped and lifted twelve randomly presented everyday objects. Grip force was measured with help of sensors fixed on thumb, index and middle-finger. The maximum rate of grip force was determined to quantify the precision of anticipation of object properties. Regression analysis yielded clear deficits of anticipation in the group of patients with left brain damage, while the comparison of patient with right brain damage with their respective control group did not reveal comparable deficits. Lesion-analyses indicate that brain structures typically associated with a tool-use network in the left hemisphere play an essential role for anticipatory grip force scaling, especially the left inferior frontal gyrus (IFG) and the premotor cortex (PMC). Furthermore, significant correlations of impaired anticipation with limb apraxia scores suggest shared representations. However, the presence of dissociations, implicates also independent processes. Overall, our findings suggest that the left hemisphere is engaged in anticipatory grip force scaling for lifting everyday objects. The underlying neural substrate is not restricted to a single region or stream; instead it may rely on

  6. Effect of three different grip angles on physical parameters during laboratory test in handcycling in able-bodied participants

    Directory of Open Access Journals (Sweden)

    Thomas eAbel

    2015-11-01

    Full Text Available Introduction: Handcycling is a relatively new wheelchair sport that has gained increased popularity for people with lower limb disabilities. The aim of this study was to examine the effect of three different grip positions on physical parameters during handcycling in a laboratory setting.Methods: Twenty one able-bodied participants performed three maximum incremental handcycling tests until exhaustion, each with a different grip angle. The angle between the grip and the crank was randomly set at 90° (horizontal, 0° (vertical or 10° (diagonal. The initial load was 20 W and increased by 20 W each five minutes. In addition, participants performed a 20 s maximum effort.Results: The relative peak functional performance (W/kg, peak heart rate (bpm, associated lactate concentrations (mmol/l and peak oxygen uptake per kilogram body weight (ml.min-1.kg-1 for the different grip positions during the stage test were: (a Horizontal: 1.43 ± 0.21 W/kg, 170.14 ± 12.81 bpm, 9.54 ± 1.93 mmol/l, 30.86 ± 4.57 ml/kg; (b Vertical: 1.38 ± 0.20 W/kg, 171.81 ± 13.87 bpm, 9.91 ± 2.29 mmol/l, 29.75 ± 5.13 ml/kg; (c Diagonal: 1.40 ± 0.22 W/kg, 169.19 ± 13.31 bpm, 9.34 ± 2.36 mmol/l, 29.39 ± 4.70 ml/kg. Statistically significant (p <0.05 differences could only be found for lactate concentration between the vertical grip position and the other grips during submaximal handcycling. Conclusion: The orientation of three different grip angles made no difference to the peak load achieved during an incremental handcycling test and a 20 second maximum effort. At submaximal load, higher lactate concentrations were found when the vertical grip position was used, suggesting that this position may be less efficient than the alternative diagonal or horizontal grip positions.

  7. Intra-session and inter-day reliability of forearm surface EMG during varying hand grip forces.

    Science.gov (United States)

    Hashemi Oskouei, Alireza; Paulin, Michael G; Carman, Allan B

    2013-02-01

    Surface electromyography (EMG) is widely used to evaluate forearm muscle function and predict hand grip forces; however, there is a lack of literature on its intra-session and inter-day reliability. The aim of this study was to determine reliability of surface EMG of finger and wrist flexor muscles across varying grip forces. Surface EMG was measured from six forearm flexor muscles of 23 healthy adults. Eleven of these subjects undertook inter-day test-retest. Six repetitions of five randomized isometric grip forces between 0% and 80% of maximum force (MVC) were recorded and normalized to MVC. Intra- and inter-day reliability were calculated through the intraclass correlation coefficient (ICC) and standard error of measurement (SEM). Normalized EMG produced excellent intra-session ICC of 0.90 when repeated measurements were averaged. Intra-session SEM was low at low grip forces, however, corresponding normalized SEM was high (23-45%) due to the small magnitude of EMG signals. This may limit the ability to evaluate finer forearm muscle function and hand grip forces in daily tasks. Combining EMG of functionally related muscles improved intra-session SEM, improving within-subject reliability without taking multiple measurements. Removing and replacing electrodes inter-day produced poor ICC (ICC < 0.50) but did not substantially affect SEM.

  8. A novel mechanism of hippocampal LTD involving muscarinic receptor-triggered interactions between AMPARs, GRIP and liprin-α

    Directory of Open Access Journals (Sweden)

    Dickinson Bryony A

    2009-06-01

    Full Text Available Abstract Background Long-term depression (LTD in the hippocampus can be induced by activation of different types of G-protein coupled receptors, in particular metabotropic glutamate receptors (mGluRs and muscarinic acethycholine receptors (mAChRs. Since mGluRs and mAChRs activate the same G-proteins and isoforms of phospholipase C (PLC, it would be expected that these two forms of LTD utilise the same molecular mechanisms. However, we find a distinct mechanism of LTD involving GRIP and liprin-α. Results Whilst both forms of LTD require activation of tyrosine phosphatases and involve internalisation of AMPARs, they use different molecular interactions. Specifically, mAChR-LTD, but not mGluR-LTD, is blocked by peptides that inhibit the binding of GRIP to the AMPA receptor subunit GluA2 and the binding of GRIP to liprin-α. Thus, different receptors that utilise the same G-proteins can regulate AMPAR trafficking and synaptic efficacy via distinct molecular mechanisms. Conclusion Our results suggest that mAChR-LTD selectively involves interactions between GRIP and liprin-α. These data indicate a novel mechanism of synaptic plasticity in which activation of M1 receptors results in AMPAR endocytosis, via a mechanism involving interactions between GluA2, GRIP and liprin-α.

  9. GRiP: a computational tool to simulate transcription factor binding in prokaryotes.

    Science.gov (United States)

    Zabet, Nicolae Radu; Adryan, Boris

    2012-05-01

    Transcription factors (TFs) are proteins that regulate gene activity by binding to specific sites on the DNA. Understanding the way these molecules locate their target site is of great importance in understanding gene regulation. We developed a comprehensive computational model of this process and estimated the model parameters in (N.R.Zabet and B.Adryan, submitted for publication). GRiP (gene regulation in prokaryotes) is a highly versatile implementation of this model and simulates the search process in a computationally efficient way. This program aims to provide researchers in the field with a flexible and highly customizable simulation framework. Its features include representation of DNA sequence, TFs and the interaction between TFs and the DNA (facilitated diffusion mechanism), or between various TFs (cooperative behaviour). The software will record both information on the dynamics associated with the search process (locations of molecules) and also steady-state results (affinity landscape, occupancy-bias and collision hotspots). http://logic.sysbiol.cam.ac.uk/grip, program and source code

  10. Electric Field Measurements During the Genesis and Rapid Intensification Processes (GRIP) Field Program

    Science.gov (United States)

    Bateman, Monte G.; Blakeslee, Richard J.; Mach, Douglas M.

    2010-01-01

    During the Genesis and Rapid Intensification Processes (GRIP) field program, a system of 6 electric field mills was flown on one of NASA's Global Hawk aircraft. We placed several mills on the aircraft to enable us to measure the vector electric field. We created a distributed, ethernet-connected system so that each sensor has its own embedded Linux system, complete with web server. This makes our current generation system fully "sensor web enabled." The Global Hawk has several unique qualities, but relevant to quality storm electric field measurements are high altitude (20 km) and long duration (20-30 hours) flights. There are several aircraft participating in the GRIP program, and coordinated measurements are happening. Lightning and electric field measurements will be used to study the relationships between lightning and other storm characteristics. It has been long understood that lightning can be used as a marker for strong convective activity. Past research and field programs suggest that lightning flash rate may serve as an indicator and precursor for rapid intensification change in tropical cyclones and hurricanes. We have the opportunity to sample hurricanes for many hours at a time and observe intensification (or de-intensification) periods. The electrical properties of hurricanes during such periods are not well known. American

  11. MusicGlove: motivating and quantifying hand movement rehabilitation by using functional grips to play music.

    Science.gov (United States)

    Friedman, Nizan; Chan, Vicky; Zondervan, Danny; Bachman, Mark; Reinkensmeyer, David J

    2011-01-01

    People with stroke typically must perform much of their hand exercise at home without professional assistance as soon as two weeks after the stroke. Without feedback and encouragement, individuals often lose motivation to practice using the affected hand, and this disuse contributes to further declines in hand function. We developed the MusicGlove as a way to facilitate and motivate at home practice of hand movement. This low-cost device uses music as an interactive and motivating medium to guide hand exercise and to quantitatively assess hand movement recovery. It requires the user to practice functional movements, including pincer grip, key-pinch grip, and finger-thumb opposition, by using those movements to play different musical notes, played along to songs displayed by an interactive computer game. We report here the design of the glove and the results of a single-session experiment with 10 participants with chronic stroke. We found that the glove is well suited for use by people with an impairment level quantified by a Box and Blocks score of at least around 7; that the glove can be used to obtain a measure of hand dexterity (% of notes hit) that correlates strongly with the Box and Blocks score; and that the incorporation of music into training significantly improved both objective measures of hand motor performance and self-ratings of motivation for training in the single session.

  12. Effect of skin hydration on the dynamics of fingertip gripping contact

    Science.gov (United States)

    André, T.; Lévesque, V.; Hayward, V.; Lefèvre, P.; Thonnard, J.-L.

    2011-01-01

    The dynamics of fingertip contact manifest themselves in the complex skin movements observed during the transition from a stuck state to a fully developed slip. While investigating this transition, we found that it depended on skin hydration. To quantify this dependency, we asked subjects to slide their index fingertip on a glass surface while keeping the normal component of the interaction force constant with the help of visual feedback. Skin deformation inside the contact region was imaged with an optical apparatus that allowed us to quantify the relative sizes of the slipping and sticking regions. The ratio of the stuck skin area to the total contact area decreased linearly from 1 to 0 when the tangential force component increased from 0 to a maximum. The slope of this relationship was inversely correlated to the normal force component. The skin hydration level dramatically affected the dynamics of the contact encapsulated in the course of evolution from sticking to slipping. The specific effect was to reduce the tendency of a contact to slip, regardless of the variations of the coefficient of friction. Since grips were more unstable under dry skin conditions, our results suggest that the nervous system responds to dry skin by exaggerated grip forces that cannot be simply explained by a change in the coefficient of friction. PMID:21490002

  13. Muscular forearm activation in hand-grip tasks with superimposition of mechanical vibrations.

    Science.gov (United States)

    Fattorini, L; Tirabasso, A; Lunghi, A; Di Giovanni, R; Sacco, F; Marchetti, E

    2016-02-01

    The purpose of this paper is to evaluate the muscular activation of the forearm, with or without vibration stimuli at different frequencies while performing a grip tasks of 45s at various level of exerted force. In 16 individuals, 9 females and 7 males, the surface electromyogram (EMG) of extensor carpi radialis longus and the flexor carpi ulnari muscles were assessed. At a short latency from onset EMG, RMS and the level of MU synchronization were assessed to evaluate the muscular adaptations. Whilst a trend of decay of EMG Median frequency (MDFd) was employed as an index of muscular fatigue. Muscular tasks consists of the grip of an instrumented handle at a force level of 20%, 30%, 40%, 60% of the maximum voluntary force. Vibration was supplied by a shaker to the hand in mono-frequential waves at 20, 30, 33 and 40Hz. In relation to EMG, RMS and MU synchronization, the muscular activation does not seem to change with the superimposition of the mechanical vibrations, on the contrary a lower MDFd was observed at 33Hz than in absence of vibration. This suggests an early muscular fatigue induced by vibration due to the fact that 33Hz is a resonance frequency for the hand-arm system.

  14. Grip selection for sequential movements in children and adults with and without Developmental Coordination Disorder.

    Science.gov (United States)

    Wilmut, Kate; Byrne, Maia

    2014-08-01

    When generating a movement adults favor grasps which start the body in an uncomfortable position if they end in a comfortable position (the end-state-comfort effect). In contrast, children with Developmental Coordination Disorder (DCD) select grasps which require little initial hand rotation even though they result in an uncomfortable end position. The current study considered grip selection of individuals with DCD when asked to make simple one step movements and when making more complex multi-staged movements. Adults with DCD (N=17, mean age 24:09, SD age=52months) and children with DCD (N=20, mean age 9:00, SD age=20months) and age and gender matched controls rotated a disc so an arrow pointed toward a specific target(s). Task complexity was increased by increasing the number of targets from 1 to 3. Planning for end-state-comfort was seen in all groups albeit to a lesser extent in children versus adults. The children with DCD showed fewer grips for end-state-comfort compared to their peers and this was explained by a propensity to select minimal initial rotation grasps. This result was mirrored in adults with DCD but only for the longest movement sequence. These results suggest some changes in ability from childhood to adulthood in individuals with DCD.

  15. The brain adjusts grip forces differently according to gravity and inertia: a parabolic flight experiment.

    Science.gov (United States)

    White, Olivier

    2015-01-01

    In everyday life, one of the most frequent activities involves accelerating and decelerating an object held in precision grip. In many contexts, humans scale and synchronize their grip force (GF), normal to the finger/object contact, in anticipation of the expected tangential load force (LF), resulting from the combination of the gravitational and the inertial forces. In many contexts, GF and LF are linearly coupled. A few studies have examined how we adjust the parameters-gain and offset-of this linear relationship. However, the question remains open as to how the brain adjusts GF regardless of whether LF is generated by different combinations of weight and inertia. Here, we designed conditions to generate equivalent magnitudes of LF by independently varying mass and movement frequency. In a control experiment, we directly manipulated gravity in parabolic flights, while other factors remained constant. We show with a simple computational approach that, to adjust GF, the brain is sensitive to how LFs are produced at the fingertips. This provides clear evidence that the analysis of the origin of LF is performed centrally, and not only at the periphery.

  16. Hurricane Imaging Radiometer Wind Speed and Rain Rate Retrievals during the 2010 GRIP Flight Experiment

    Science.gov (United States)

    Sahawneh, Saleem; Farrar, Spencer; Johnson, James; Jones, W. Linwood; Roberts, Jason; Biswas, Sayak; Cecil, Daniel

    2014-01-01

    Microwave remote sensing observations of hurricanes, from NOAA and USAF hurricane surveillance aircraft, provide vital data for hurricane research and operations, for forecasting the intensity and track of tropical storms. The current operational standard for hurricane wind speed and rain rate measurements is the Stepped Frequency Microwave Radiometer (SFMR), which is a nadir viewing passive microwave airborne remote sensor. The Hurricane Imaging Radiometer, HIRAD, will extend the nadir viewing SFMR capability to provide wide swath images of wind speed and rain rate, while flying on a high altitude aircraft. HIRAD was first flown in the Genesis and Rapid Intensification Processes, GRIP, NASA hurricane field experiment in 2010. This paper reports on geophysical retrieval results and provides hurricane images from GRIP flights. An overview of the HIRAD instrument and the radiative transfer theory based, wind speed/rain rate retrieval algorithm is included. Results are presented for hurricane wind speed and rain rate for Earl and Karl, with comparison to collocated SFMR retrievals and WP3D Fuselage Radar images for validation purposes.

  17. Positive force feedback in development of substrate grip in the stick insect tarsus.

    Science.gov (United States)

    Zill, Sasha N; Chaudhry, Sumaiya; Exter, Annelie; Büschges, Ansgar; Schmitz, Josef

    2014-09-01

    The mechanics of substrate adhesion has recently been intensively studied in insects but less is known about the sensorimotor control of substrate engagement. We characterized the responses and motor effects of tarsal campaniform sensilla in stick insects to understand how sensory signals of force could contribute to substrate grip. The tarsi consist of a chain of segments linked by highly flexible articulations. Morphological studies showed that one to four campaniform sensilla are located on the distal end of each segment. Activities of the receptors were recorded neurographically and sensilla were identified by stimulation and ablation of their cuticular caps. Responses were characterized to bending forces and axial loads, muscle contractions and to forces applied to the retractor apodeme (tendon). The tarsal sensilla effectively encoded both the rate and amplitude of loads and muscle forces, but only when movement was resisted. Mechanical stimulation of the receptors produced activation of motor neurons in the retractor unguis and tibial flexor muscles. These findings indicate that campaniform sensilla can provide information about the effectiveness of the leg muscles in generating substrate adherence. They can also produce positive force feedback that could contribute to the development of substrate grip and stabilization of the tarsal chain.

  18. Adsorption Removal of Phenols from Water by CTMAB-Bent and HDBAC-Bent%CTMAB -膨润土和 HDBAC -膨润土吸附去除水中酚类有机污染物

    Institute of Scientific and Technical Information of China (English)

    王闻捷; 虞卉; 陈晨; 郑凯琳; 杨超颖; 徐立恒

    2015-01-01

    Aiming to the removal of phenols from water , organobentonites (HDBAC-Bent and CTMAB-Bent) were fabrica-ted with HDBAC and CTMAB as modifiers , and their structure were characterized with FTIR and SEM .The adsorption ca-pacities of organobentonites towards phenols from single-solute and bi-solute system were studied .It was found that the ad-sorption ability of the two organobentonites towards 2-naphthol was remarkably higher than that towards phenol .In the bi-solute system, the adsorption of 2-naphthol was hardly effected by coexisted phenol , while the existing of 2-naphthol dra-matically reduce the adsorption of phenol .Comparing to CTMAB-Bent, the adsorption ability of HDBAC-Bent towards 2-naphthol was much higher .%针对水中酚类有机污染物的去除,十六烷基二甲基苄基氯化铵( HDBAC )和十六烷基三甲基溴化铵( CT-MAB)为改性剂在制备了两种有机膨润土( HDBAC-Bent和CTMAB-Bent),并以红外光谱和扫描电子显微镜对有机膨润土的结构进行表征。同时,考察了有机膨润土对单一和复合污染体系中苯酚和2-萘酚的吸附性能,研究发现两种有机膨润土对2-萘酚的吸附能力远远大于对苯酚的吸附,在两种有机物共存时,2-萘酚的吸附受苯酚影响很少,而苯酚的吸附显著受到抑制。

  19. EFFICACY OF MULLIGAN’S TWO LEG ROTATION AND BENT LEG RAISE TECHNIQUES IN HAMSTRING FLEXIBILITY IN SUBJECTS WITH ACUTE NON-SPECIFIC LOW BACK PAIN: RANDOMIZED CLINICAL TRIAL

    Directory of Open Access Journals (Sweden)

    Pratik .A. Phansopkar,

    2014-10-01

    Full Text Available Background and objectives: Adequate flexibility of the Hamstring muscles and Core muscle strength is necessary for a healthy lower back. Mulligan’s techniques are fascinating Physiotherapy approach in treatment of hamstrings tightness in NS-LBP such as Mulligan’s Bent Leg Raise (BLR technique, Limited Literature is available on the efficacies of Mulligan’s Two Leg Rotation (TLR technique in Hamstrings flexibility. The objective of the present study was to determine the effectiveness of Mulligan’s TLR and BLR in treatment of acute NS-LBP. Methods: The present randomized clinical trial was conducted among 40 subjects which included both male and female symptomatic subjects between the age of 18 to 35 years with acute NS-LBP and they were randomly allocated into 2 groups namely Group A[SWD, HMP, Mulligan’s TLR, MCE] , Group B[SWD, HMP, Mulligan’s BLR, MCE]. Pre-interventional and 7th day Post-interventional outcome measurements were taken in the form of Visual Analogue Scale (VAS, Modified Oswestry Disability Questionnaire (MODQ, Active Knee Extension (AKE Measurement, Lumbar ROM and Core muscle strength. Results: Intra-group comparison for all the outcome parameters in both the groups showed statistical significance (p<0.001. Inter group comparison for all the outcome parameters had differences but showed no statistical significance. Conclusion: Mulligan’s Two Leg Rotation and Bent Leg Raise techniques are effective in increasing the hamstrings flexibility in subjects with acute non specific low back pain in terms of pain, range of motion and functional disability.

  20. Laterality of handgrip strength: age- and physical training-related changes in Lithuanian schoolchildren and conscripts.

    Science.gov (United States)

    Tutkuviene, Janina; Schiefenhövel, Wulf

    2013-06-01

    Laterality in handgrip strength was assessed by analyzing dynamometric data of the right and left hand in three samples of Lithuanian boys and girls aged 7-20 years. In addition, the influence of general physical training on the laterality of handgrip strength was explored in a sample of conscripts. A negative secular trend in handgrip strength of schoolchildren has been detected since 1965, and with increasing age, right-handedness has become more pronounced. Children that were ambidextrous (by grip strength) showed negative deviations in physical status more often than their right- or left-handed peers. During one year of physical training, the conscripts had a larger increase in grip strength of the left than in the right hand, and a marked shift in handgrip laterality toward left-handed and ambidextrous individuals was observed. The different impact of schooling and physical training on handgrip strength laterality might partly explain variations in the prevalence of handedness in different societies with divergent cultures and lifestyles (e.g., more or less sedentary). © 2013 New York Academy of Sciences.

  1. GRIP: A web-based system for constructing Gold Standard datasets for protein-protein interaction prediction.

    Science.gov (United States)

    Browne, Fiona; Wang, Haiying; Zheng, Huiru; Azuaje, Francisco

    2009-01-26

    Information about protein interaction networks is fundamental to understanding protein function and cellular processes. Interaction patterns among proteins can suggest new drug targets and aid in the design of new therapeutic interventions. Efforts have been made to map interactions on a proteomic-wide scale using both experimental and computational techniques. Reference datasets that contain known interacting proteins (positive cases) and non-interacting proteins (negative cases) are essential to support computational prediction and validation of protein-protein interactions. Information on known interacting and non interacting proteins are usually stored within databases. Extraction of these data can be both complex and time consuming. Although, the automatic construction of reference datasets for classification is a useful resource for researchers no public resource currently exists to perform this task. GRIP (Gold Reference dataset constructor from Information on Protein complexes) is a web-based system that provides researchers with the functionality to create reference datasets for protein-protein interaction prediction in Saccharomyces cerevisiae. Both positive and negative cases for a reference dataset can be extracted, organised and downloaded by the user. GRIP also provides an upload facility whereby users can submit proteins to determine protein complex membership. A search facility is provided where a user can search for protein complex information in Saccharomyces cerevisiae. GRIP is developed to retrieve information on protein complex, cellular localisation, and physical and genetic interactions in Saccharomyces cerevisiae. Manual construction of reference datasets can be a time consuming process requiring programming knowledge. GRIP simplifies and speeds up this process by allowing users to automatically construct reference datasets. GRIP is free to access at http://rosalind.infj.ulst.ac.uk/GRIP/.

  2. GRIP: A web-based system for constructing Gold Standard datasets for protein-protein interaction prediction

    Directory of Open Access Journals (Sweden)

    Zheng Huiru

    2009-01-01

    Full Text Available Abstract Background Information about protein interaction networks is fundamental to understanding protein function and cellular processes. Interaction patterns among proteins can suggest new drug targets and aid in the design of new therapeutic interventions. Efforts have been made to map interactions on a proteomic-wide scale using both experimental and computational techniques. Reference datasets that contain known interacting proteins (positive cases and non-interacting proteins (negative cases are essential to support computational prediction and validation of protein-protein interactions. Information on known interacting and non interacting proteins are usually stored within databases. Extraction of these data can be both complex and time consuming. Although, the automatic construction of reference datasets for classification is a useful resource for researchers no public resource currently exists to perform this task. Results GRIP (Gold Reference dataset constructor from Information on Protein complexes is a web-based system that provides researchers with the functionality to create reference datasets for protein-protein interaction prediction in Saccharomyces cerevisiae. Both positive and negative cases for a reference dataset can be extracted, organised and downloaded by the user. GRIP also provides an upload facility whereby users can submit proteins to determine protein complex membership. A search facility is provided where a user can search for protein complex information in Saccharomyces cerevisiae. Conclusion GRIP is developed to retrieve information on protein complex, cellular localisation, and physical and genetic interactions in Saccharomyces cerevisiae. Manual construction of reference datasets can be a time consuming process requiring programming knowledge. GRIP simplifies and speeds up this process by allowing users to automatically construct reference datasets. GRIP is free to access at http://rosalind.infj.ulst.ac.uk/GRIP/.

  3. Modeling the Maturation of Grip Selection Planning and Action Representation: Insights from Typical and Atypical Motor Development.

    Directory of Open Access Journals (Sweden)

    Ian eFuelscher

    2016-02-01

    Full Text Available We investigated the purported association between developmental changes in grip selection planning and improvements in an individual’s capacity to represent action at an internal level (i.e., motor imagery. Participants were groups of healthy children aged 6-7 years and 8-12 years respectively, while a group of adolescents (13-17 years and adults (18-34 years allowed for consideration of childhood development in the broader context of motor maturation. A group of children aged 8-12 years with probable DCD (pDCD was included as a reference group for atypical motor development. Participants’ proficiency to generate and/or engage internal action representations was inferred from performance on the hand rotation task, a well-validated measure of motor imagery. A grip selection task designed to elicit the end-state comfort (ESC effect provided a window into the integrity of grip selection planning. Consistent with earlier accounts, the efficiency of grip selection planning followed a non-linear developmental progression in neurotypical individuals. As expected, analysis confirmed that these developmental improvements were predicted by an increased capacity to generate and/or engage internal action representations. The profile of this association remained stable throughout the (typical developmental spectrum. These findings are consistent with computational accounts of action planning that argue that internal action representations are associated with the expression and development of grip selection planning across typical development. However, no such association was found for our sample of children with pDCD, suggesting that individuals with atypical motor skill may adopt an alternative, sub-optimal strategy to plan their grip selection compared to their same-age control peers.

  4. Modeling the Maturation of Grip Selection Planning and Action Representation: Insights from Typical and Atypical Motor Development

    Science.gov (United States)

    Fuelscher, Ian; Williams, Jacqueline; Wilmut, Kate; Enticott, Peter G.; Hyde, Christian

    2016-01-01

    We investigated the purported association between developmental changes in grip selection planning and improvements in an individual’s capacity to represent action at an internal level [i.e., motor imagery (MI)]. Participants were groups of healthy children aged 6–7 years and 8–12 years respectively, while a group of adolescents (13–17 years) and adults (18–34 years) allowed for consideration of childhood development in the broader context of motor maturation. A group of children aged 8–12 years with probable DCD (pDCD) was included as a reference group for atypical motor development. Participants’ proficiency to generate and/or engage internal action representations was inferred from performance on the hand rotation task, a well-validated measure of MI. A grip selection task designed to elicit the end-state comfort (ESC) effect provided a window into the integrity of grip selection planning. Consistent with earlier accounts, the efficiency of grip selection planning followed a non-linear developmental progression in neurotypical individuals. As expected, analysis confirmed that these developmental improvements were predicted by an increased capacity to generate and/or engage internal action representations. The profile of this association remained stable throughout the (typical) developmental spectrum. These findings are consistent with computational accounts of action planning that argue that internal action representations are associated with the expression and development of grip selection planning across typical development. However, no such association was found for our sample of children with pDCD, suggesting that individuals with atypical motor skill may adopt an alternative, sub-optimal strategy to plan their grip selection compared to their same-age control peers. PMID:26903915

  5. ANGIOTENSIN-CONVERTING ENZYME GENOTYPE AFFECTS SKELETAL MUSCLE STRENGTH IN ELITE ATHLETES

    Directory of Open Access Journals (Sweden)

    Aldo Matos Costa

    2009-09-01

    Full Text Available Previous studies have associated angiotensin-converting enzyme (ACE D allele with variability in the skeletal muscle baseline strength, though conclusions have been inconsistent across investigations. The purpose of this study was to examine the possible association between ACE genotype and skeletal muscle baseline strength in elite male and female athletes involved in different event expertise. A group of 58 elite athletes, designated as Olympic candidates, were studied: 35 swimmers (19 males and 16 females, 18.8 ± 3.2 years and 23 triathletes (15 males and 8 females, 18.7 ± 3.0 years. The athletes were classified as: short (< 200m and middle (400m to 1500m distance athletes, respectively. For each subject the grip strength in both hands was measure using an adjustable mechanical hand dynamometer. The maximum height in both squat jump (SJ and counter movement jump (CMJ were also assessed, using a trigonometric carpet (Ergojump Digitime 1000; Digitest, Jyvaskyla, Finland. DNA extraction was obtained with Chelex 100® and genotype determination by PCR-RFLP methods. Both males and females showed significantly higher right grip strength in D allele carriers compared to II homozygote's. We found that allelic frequency differs significantly by event distance specialization in both genders (p < 0.05. In fact, sprinter D allele carriers showed the superior scores in nearly all strength measurements (p < 0.05, in both genders. Among endurance athletes, the results also demonstrated that female D allele carriers exhibited the higher performance right grip and CMJ scores (p < 0.05. In conclusion, the ACE D allele seems associated with skeletal muscle baseline strength in elite athletes, being easily identified in females

  6. The responsiveness of sensibility and strength tests in patients undergoing carpal tunnel decompression

    Directory of Open Access Journals (Sweden)

    Miller Leanne

    2011-10-01

    Full Text Available Abstract Background Several clinical measures of sensory and motor function are used alongside patient-rated questionnaires to assess outcomes of carpal tunnel decompression. However there is a lack of evidence regarding which clinical tests are most responsive to clinically important change over time. Methods In a prospective cohort study 63 patients undergoing carpal tunnel decompression were assessed using standardised clinician-derived and patient reported outcomes before surgery, at 4 and 8 months follow up. Clinical sensory assessments included: touch threshold with monofilaments (WEST, shape-texture identification (STI™ test, static two-point discrimination (Mackinnon-Dellon Disk-Criminator and the locognosia test. Motor assessments included: grip and tripod pinch strength using a digital grip analyser (MIE, manual muscle testing of abductor pollicis brevis and opponens pollicis using the Rotterdam Intrinsic Handheld Myometer (RIHM. The Boston Carpal Tunnel Questionnaire (BCTQ was used as a patient rated outcome measure. Results Relative responsiveness at 4 months was highest for the BCTQ symptom severity scale with moderate to large effects sizes (ES = -1.43 followed by the BCTQ function scale (ES = -0.71. The WEST and STI™ were the most responsive sensory tests at 4 months showing moderate effect sizes (WEST ES = 0.55, STI ES = 0.52. Grip and pinch strength had a relatively higher responsiveness compared to thenar muscle strength but effect sizes for all motor tests were very small (ES ≤0.10 or negative indicating a decline compared to baseline in some patients. Conclusions For clinical assessment of sensibility touch threshold assessed by monofilaments (WEST and tactile gnosis measured with the STI™ test are the most responsive tests and are recommended for future studies. The use of handheld myometry (RIHM for manual muscle testing, despite more specifically targeting thenar muscles, was less responsive than grip or tripod

  7. Relaxation of axially confined 400 GeV/c protons to planar channeling in a bent crystal

    CERN Document Server

    Bandiera, L; Bagli, E; Germogli, G; Guidi, V; Sytov, A; Kirillin, I V; Shul'ga, N F; Berra, A; Lietti, D; Prest, M; De Salvador, D; Vallazza, E

    2016-01-01

    An investigation on the mechanism of relaxation of axially confined 400 GeV/c protons to planar channeling in a bent crystal was carried out at the extracted line H8 from CERN Super Proton Synchrotron. The experimental results were critically compared to computer simulations, showing a good agreement. We firmly individuated a necessary condition for the exploitation of axial confinement or its relaxation for particle beam manipulation in high-energy accelerators. We demonstrated that with a short bent crystal, aligned with one of its main axis to the beam direction, it is possible to realize either a total beam steerer or a beam splitter with adjustable intensity. In particular, in the latter case, a complete relaxation from axial confinement to planar channeling takes place, resulting in beam splitting into the two strongest skew planar channels.

  8. First observation of multiple volume reflection by different planes in one bent silicon crystal for high-energy protons

    CERN Document Server

    Scandale, E; Bagli, E; Baricordi, S; Dalpiaz, P; Fiorini, M; Guidi, V; Mazzolari, A; Vincenzi, D; Milan, R; Della Mea, Gianantonio; Vallazza, E; Afonin, A G; Chesnokov, Yu A; Maisheev, V A; Yazynin, I A; Golovatyuk, V M; Kovalenko, A D; Taratin, A M; Denisov, A S; Gavrikov, Yu A; Ivanov, Yu M; Lapina, L P; Malyarenko, L G; Skorobogatov, V V; Suvorov, V M; Vavilov, S A; Bolognini, D; Hasan, S; Mattera, A; Prest, M; Tikhomirovl, V V

    2009-01-01

    Multiple volume reflection by different planes in a bent silicon crystal with its 111 axis orientation close to the beam direction was observed for the first time for 400 GeV/c protons at the CERN SPS. The proton beam was deflected to the side opposite to the crystal bend by an angle of about 67 μrad, which is five times larger than in a single volume reflection by the (110) bent planes. The registered efficiency of one side deflection was about 84%. It was shown that multiple volume reflection transforms to a single volume reflection when the orientation angle of the 111 axis relative to the beam direction is increased

  9. Relaxation of axially confined 400 GeV/c protons to planar channeling in a bent crystal

    Energy Technology Data Exchange (ETDEWEB)

    Bandiera, L.; Mazzolari, A.; Bagli, E.; Germogli, G.; Guidi, V. [Universita di Ferrara, Dipartimento di Fisica, Ferrara (Italy); INFN, Ferrara (Italy); Sytov, A. [Universita di Ferrara, Dipartimento di Fisica, Ferrara (Italy); Belarusian State University, Research Institute for Nuclear Problems, Minsk (Belarus); INFN, Ferrara (Italy); Kirillin, I.V. [National Science Center ' ' Kharkov Institute of Physics and Technology' ' , Akhiezer Institute for Theoretical Physics, Kharkov (Ukraine); Shul' ga, N.F. [National Science Center ' ' Kharkov Institute of Physics and Technology' ' , Akhiezer Institute for Theoretical Physics, Kharkov (Ukraine); V.N. Karazin Kharkov National University, Kharkov (Ukraine); Berra, A.; Lietti, D.; Prest, M. [Universita dell' Insubria, Como (Italy); INFN Sezione di Milano Bicocca, Milan (Italy); De Salvador, D. [INFN Laboratori Nazionali di Legnaro, Legnaro (Italy); Universita di Padova, Dipartimento di Fisica, Padua (Italy); Vallazza, E. [INFN Sezione di Trieste, Trieste (Italy)

    2016-02-15

    An investigation on the mechanism of relaxation of axially confined 400 GeV/c protons to planar channeling in a bent crystal was carried out at the extracted line H8 from CERN Super Proton Synchrotron. The experimental results were critically compared to computer simulations, showing a good agreement. We identified a necessary condition for the exploitation of axial confinement or its relaxation for particle beam manipulation in high-energy accelerators. We introduce the idea of using a short bent crystal, aligned with one of its main axis to the beam direction, as a beam steerer or a beam splitter with adjustable intensity in the field of particle accelerators. In particular, in the latter case, a complete relaxation from axial confinement to planar channeling takes place, resulting in beam splitting into the two strongest skew planar channels. (orig.)

  10. Focusing effect of bent GaAs crystals for gamma-ray Laue lenses: Monte Carlo and experimental results

    CERN Document Server

    Virgilli, E; Rosati, P; Bonnini, E; Buffagni, E; Ferrari, C; Stephen, J B; Caroli, E; Auricchio, N; Basili, A; Silvestri, S

    2015-01-01

    We report on results of observation of the focusing effect from the planes (220) of Gallium Arsenide (GaAs) crystals. We have compared the experimental results with the simulations of the focusing capability of GaAs tiles through a developed Monte Carlo. The GaAs tiles were bent using a lapping process developed at the cnr/imem - Parma (Italy) in the framework of the laue project, funded by ASI, dedicated to build a broad band Laue lens prototype for astrophysical applications in the hard X-/soft gamma-ray energy range (80-600 keV). We present and discuss the results obtained from their characterization, mainly in terms of focusing capability. Bent crystals will significantly increase the signal to noise ratio of a telescope based on a Laue lens, consequently leading to an unprecedented enhancement of sensitivity with respect to the present non focusing instrumentation.

  11. Sistemática de Foraminíferos Bentónicos de playa Gómez isla Gorgona

    Directory of Open Access Journals (Sweden)

    Londoño de Hoyos Concha

    1996-06-01

    Full Text Available One hundred species of benthonic Foraminifera grouped in 46 genera, 22 families, 9 superfamilies and 3 suborders were identified. The total number of individuals studied was 1.445; according to the data repported by the literature on benthonic Foraminifera, 77% of the individuals studied could be considered as in sifu fauna, the rernaining 23% are considered as displaced tests.Se identificaron 100 especies de foraminíferos bentónicos, agrupados en 46 géneros, 22 familias, 9 superfamilias y 3 subórdenes. El total de individuos estudiados es de 1.44'5; un 77% de ellos, de acuerdo con los registros en la literatura sobre distribución de foraminíferos bentónicos, se pueden considerar
    como fauna in situ, el 23% restante se considera como caparazones desplazados.

  12. Analysis of surface plasmon resonance in bent single-mode waveguides with metal-coated cladding by eigenmode expansion method.

    Science.gov (United States)

    Kulchin, Yu N; Vitrik, O B; Dyshlyuk, A V

    2014-09-08

    A numerical study is presented of surface plasmon waves excitation in a metal film applied to the cladding of a standard bent single-mode optical fiber. It was shown that by adjusting the bend radius and metal film thickness one can achieve effective coupling between the fiber fundamental mode and symmetric surface plasmon mode through the intermediary of whispering gallery modes supported by the cladding of the bent fiber. This effect is demonstrated to allow for refractometric measurement both in the wavelength and intensity-modulated regimes with a resolution of up to 10⁻⁸ RIU. Usage of standard noise reduction techniques for intensity-modulated optical signals promises further increase in accuracy.

  13. Free-living benthic marine invertebrates in Chile Invertebrados bentónicos marinos de vida libre en Chile

    Directory of Open Access Journals (Sweden)

    MATTHEW R LEE

    2008-03-01

    Full Text Available A comprehensive literature review was conducted to determine the species richness of all the possible taxa of free-living benthic marine invertebrates in Chile. In addition, the extent of endemism to the Pacific Islands and deep-sea, the number of non-indigenous species, and the contribution that the Chilean benthic marine invertebrate fauna makes to the world benthic marine invertebrate fauna was examined. A total of 4,553 species were found. The most speciose taxa were the Crustacea, Mollusca and Polychaeta. Species richness data was not available for a number of taxa, despite evidence that these taxa are present in the Chilean benthos. The Chilean marine invertebrate benthic fauna constitutes 2.47 % of the world marine invertebrate benthic fauna. There are 599 species endemic to the Pacific Islands and 205 in the deep-sea. There are 25 invasive or non-indigenous species so far identified in Chile. Though the Chilean fauna is speciose there is still a considerable amount of diversity yet to be described, particularly amongst the small bodied invertebrates and from the less well explored habitats, such as the deep-seaSe realizó una revisión exhaustiva de la literatura para determinar la riqueza de especies de todos los taxa de invertebrados bentónicos de vida libre en Chile. Además, se analizó el endemismo de invertebrados marinos bentónicos para las islas chilenas del Pacífico y el mar profundo y el número de especies no indígenas; del mismo modo que la contribución de estos invertebrados a la riqueza mundial de invertebrados bentónicos marinos. Para Chile se acumuló un total de 4.553 especies de invertebrados bentónicos. Los taxa con más especies fueron Crustacea, Mollusca y Polychaeta. En algunos taxa de invertebrados no se encontró información sobre la diversidad de especies presentes en Chile, a pesar de existir evidencia de que éstos están presentes en el bentos marino chileno. Los invertebrados bentónicos marinos

  14. Leaning-type polar smectic-C phase in a freely suspended bent-core liquid crystal film.

    Science.gov (United States)

    Chattham, Nattaporn; Tamba, Maria-Gabriela; Stannarius, Ralf; Westphal, Eduard; Gallardo, Hugo; Prehm, Marko; Tschierske, Carsten; Takezoe, Hideo; Eremin, Alexey

    2015-03-01

    A rich variety of responsive behavior occurs in complex structured fluids due to their lower symmetries. On the other hand, fluid disorder tends to increase the symmetry of liquid crystal mesophases. Here, we report direct evidence for the existence of a mesophase with CS symmetry. The observations are based on optical studies of director inversion walls in freely suspended films in electric fields under obliquely incident light. This phase is distinguished by the polarization lying in the molecular tilt plane in freely suspended films. Such a low-symmetry polar fluid phase has been long predicted to occur in bent-core liquid crystals. The stability of this phase is attributed to the bent shape of the mesogens and dominating dispersion interactions.

  15. First Observation of the Deflection of a 33 TeV Pb Ion Beam in a Bent Silicon Crystal

    Science.gov (United States)

    Elsener, K.; Biino, C.; Clement, M.; Doble, N.; Gatignon, L.; Grafstrom, P.; Mikkelsen, U.; Taratin, A.; Møller, S. P.; Uggerhøj, E.

    1997-05-01

    The deflection of an ultra-relativistic, fully stripped Pb(82+) ion beam in a bent silicon crystal has been observed for the first time. The ions were provided by the CERN-SPS in the H4 beam at a momentum of 400 GeV/c/Z. A 60 mm long silicon crystal, bent over 50 mm to give a 4 mrad deflection angle, was used in this experiment. The measured Pb ion deflection efficiencies are comparable to the ones obtained with protons at an equivalent ratio p/Z, and are found to be about 15% for a beam with a divergence of 50 microradians (FWHM). The interaction rate observed in a background counter is reduced by about the same 15% when the crystal is well aligned with the beam. This corroborates further the channeling model, which predicts that channeled ions are steered away from regions of high electron densities as well as from the nuclei in the crystal.

  16. Observation and comparative analysis of proton beam extraction or collimation by different planar channels of a bent crystal

    Directory of Open Access Journals (Sweden)

    A. G. Afonin

    2012-08-01

    Full Text Available In the experiment the efficiency of the 50 GeV proton beam extraction from accelerator by means of a bent crystal as a function of crystal orientation was measured. This allowed one to make a comparative analysis of efficiencies of high-energy protons deflection by different crystal atomic planes with different values of the electrostatic field. The results of simulation of high-energy protons deflection by means of crystal atomic planes and crystal atomic strings are also presented in the article. In the case of planar channeling the simulation shows a good agreement with experimental data. In the case of proton motion in the regime of stochastic scattering by bent atomic strings the simulation shows that angles of particle deflection are much greater than the critical channeling angle.

  17. Effect of isometric hand grip on heart rate in normotensive and hypertensive individuals during head up tilt (300 and 600)

    OpenAIRE

    Badwe, A. N.; Latti, Ramchandra Girimalappa

    2017-01-01

    Objective: To study the effect of isometric hand grip exercise at 20% on normotensive, treated hypertensive, and non treated hypertensive in supine position, and at 300 and 600 head up tilt.Material and Methods: After recording heart rate in supine position, isometric hand grip exercise at 20% was conducted for 2 minutes with dominant hand and heart rate was recorded for 1 minute in all subjects after end of the exercise. The same maneuver was repeated before head up tilt in supine position a...

  18. High resolution X-ray spherically bent crystal spectrometer for laser-produced plasma diagnostics

    Institute of Scientific and Technical Information of China (English)

    Shali Xiao; Hongjian Wang; Jun Shi; Changhuan Tang; Shenye Liu

    2009-01-01

    A new high spectral resolution crystal spectrometer is designed to measure very low emissive X-ray spectra of laser-produced plasma in 0.5 - 0.9 nm range. A large open aperture (30 x 20 (mm)) mica (002) spherically bent crystal with curvature radius R = 380 mm is used as dispersive and focusing element. The imaging plate is employed to obtain high spectral resolution with effective area of 30 x 80 (mm). The long designed path of the X-ray spectrometer beam is 980 mm from the source to the detector via the crystal. Experiment is carried out at a 20-J laser facility. X-ray spectra in an absolute intensity scale is obtained from Al laser produced plasmas created by laser energy of 6.78 J. Samples of spectra obtained with spectral resolution of up to E/鈻矱 ~ 1500 are presented. The results clearly show that the device is good to diagnose laser high-density plasmas.

  19. Standard practice for preparation and use of Bent-Beam stress-corrosion test specimens

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2011-01-01

    1.1 This practice covers procedures for designing, preparing, and using bent-beam stress-corrosion specimens. 1.2 Different specimen configurations are given for use with different product forms, such as sheet or plate. This practice applicable to specimens of any metal that are stressed to levels less than the elastic limit of the material, and therefore, the applied stress can be accurately calculated or measured (see Note 1). Stress calculations by this practice are not applicable to plastically stressed specimens. Note 1—It is the nature of these practices that only the applied stress can be calculated. Since stress-corrosion cracking is a function of the total stress, for critical applications and proper interpretation of results, the residual stress (before applying external stress) or the total elastic stress (after applying external stress) should be determined by appropriate nondestructive methods, such as X-ray diffraction (1). 1.3 Test procedures are given for stress-corrosion testing by ex...

  20. Characterization of kink actuators as compared to traditional chevron shaped Bent-Beam electrothermal actuators

    KAUST Repository

    Rawashdeh, E.

    2012-07-06

    This paper compares the design and performance of kink actuators, a modified version of the bent-beam thermal actuator, to the standard chevron-shaped designs. A variety of kink and chevron actuator designs were fabricated from polysilicon. While the actuators were electrically probed, these designs were tested using a probe station connected to a National Instruments (NI) controller that uses LabVIEW to extract the displacement results via image processing. The displacement results were then used to validate the thermal-electric-structural simulations produced by COMSOL. These results, in turn, were used to extract the stiffness for both actuator types. The data extracted show that chevron actuators can have larger stiffness values with increasing offsets, but at the cost of lower amplification factors. In contrast, kink actuators showed a constant stiffness value equivalent to the chevron actuator with the highest amplification factor. The kink actuator also had larger amplification factors than chevrons at all designs tested. Therefore, kink actuators are capable of longer throws at lower power levels than the standard chevron designs.

  1. New Results from the Solar Maximum Mission/Bent Crystal Spectrometer

    Science.gov (United States)

    Rapley, C. G.; Sylwester, J.; Phillips, K. J. H.

    2017-04-01

    The Bent Crystal Spectrometer (BCS) onboard the NASA Solar Maximum Mission was part of the X-ray Polychromator, which observed numerous flares and bright active regions from February to November 1980, when operation was suspended as a result of the failure of the spacecraft fine-pointing system. Observations resumed following the Space Shuttle SMM Repair Mission in April 1984 and continued until November 1989. BCS spectra have been widely used in the past to obtain temperatures, emission measures, and turbulent and bulk flows during flares, as well as element abundances. Instrumental details including calibration factors not previously published are given here, and the in-orbit performance of the BCS is evaluated. Some significant changes during the mission are described, and recommendations for future instrumentation are made. Using improved estimates for the instrument parameters and operational limits, it is now possible to obtain de-convolved calibrated spectra that show finer detail than before, providing the means for improved interpretation of the physics of the emitting plasmas. The results indicate how historical archived data can be re-used to obtain enhanced and new, scientifically valuable results.

  2. Manufacturing of advanced bent crystals for Laue Optics for Gamma ObservationS (LOGOS)

    Energy Technology Data Exchange (ETDEWEB)

    Mazzolari, Andrea, E-mail: mazzolari@fe.infn.it [Department of Physics and Earth Sciences, University of Ferrara, Via Saragat 1/c, 44122 Ferrara (Italy); INFN, Section of Ferrara (Italy); Camattari, Riccardo; Bellucci, Valerio; Paternò, Gianfranco [Department of Physics and Earth Sciences, University of Ferrara, Via Saragat 1/c, 44122 Ferrara (Italy); INFN, Section of Ferrara (Italy); Scian, Carlo; Mattei, Giovanni [University of Padova, Department of Physics and Astronomy Galileo Galilei (Italy); Guidi, Vincenzo [Department of Physics and Earth Sciences, University of Ferrara, Via Saragat 1/c, 44122 Ferrara (Italy); INFN, Section of Ferrara (Italy)

    2015-07-15

    X- and γ-ray detection is currently a hot topic for a wide scientific community, spanning from astrophysics to nuclear medicine. However, lack of optics capable of focusing photons of energies in the energy range 0.1–1 MeV leaves the photon detection to a direct-view approach, resulting in a limited efficiency and resolution. The main scope of the INFN-LOGOS project is the development of technologies that enable manufacturing highly performing optical elements to be employed in the realization of hard X-ray lenses. Such lenses, typically named Laue lenses, consist of an ensemble of crystals disposed in concentric rings in order to diffract the incident radiation towards the focus of the lens, where a detector is placed. In particular, the INFN-LOGOS project aims at the realization of intrinsically bent silicon and germanium crystals exploiting the quasi-mosaic effect for focusing hard X-rays. Crystal manufacturing relies on a proper revisitation of techniques typically employed in silicon micromachining, such as thin film deposition and patterning or ion implantation.

  3. LSPR enhanced gasoline sensing with a U-bent optical fiber

    Science.gov (United States)

    Paul, D.; Dutta, S.; Biswas, R.

    2016-08-01

    We report here a gasoline sensor utilizing localized surface plasmon resonance (LSPR) phenomenon of metal nanoparticles (NPs) with a U-bent optical fiber. The optical response of the noble metal NPs upon interaction with gasoline has been simulated and experimentally demonstrated. The increase in gasoline vapor over a period of time induces a change in the refractive index of the adjacent medium of nanoparticle colloids, adhering to the probe, and thus the variation has been observed accordingly. This change in the refractive index in the close proximity to noble metals NPs produces a measurable variation in the output signal that has been correlated with the increase in the concentration of gasoline. The sensor provides better sensitivity corresponding to AgNPs when compared to AuNPs. However, in terms of stability, AuNPs-based LSPR performs better than the AgNPs-based plasmonic response. The present sensing set-up offers a light weight, robust and easy to implement platform that has potent application in detecting volatile liquids very effectively.

  4. Numerical analysis of angular defects in bent plates using tone burst eddy-current thermography (TBET)

    Science.gov (United States)

    Libin, M. N.; Balasubramaniam, Krishnan; Maxfield, B. W.

    2013-01-01

    Tone Burst Eddy current Thermography (TBET) is a new hybrid, non-contacting, Non-Destructive Evaluation (NDT) method which employs a combination of Pulsed Eddy current Thermography (PEC) and Thermographic Non-Destructive Evaluation (TNDE). For understanding angular cracks, fundamental knowledge about the induced current density distribution in the component under test is required. Further, this information enables us to find the amount of heat produced at those locations and how it diffuses to the surface. This paper describes simulation work done for cracks set at an angle to the surface in flat and bent aluminum plates. The investigation is implemented by the simulating transient thermal distribution for 2D angular cracks via finite element package COMSOL multi-physics with AC/DC module and general heat transfer. At crack edges, induced current is seen concentrated thus indicating a localized high heating in those areas relative to other regions. A numerical study was also carried out by varying parameters like crack angle (0°, 22.5°, 45°, 67.5°) and crack length (0.6mm, 1.2mm, 1.8mm) the transient thermal distributions were compared for different plate bend angles (180°, 120°, 90°, 60°, 30°). TBET method was found well suited for the detection of service induced cracks, usually caused by either rolling contact fatigue or stress corrosion, with a high degree of sensitivity.

  5. Analysis of mitochondrial mechanical dynamics using a confocal fluorescence microscope with a bent optical fibre.

    Science.gov (United States)

    Li, Yongbo; Honda, Satoshi; Iwami, Kentaro; Ohta, Yoshihiro; Umeda, Norihiro

    2015-11-01

    The cells in the cardiovascular system are constantly subjected to mechanical forces created by blood flow and the beating heart. The effect of forces on cells has been extensively investigated, but their effect on cellular organelles such as mitochondria remains unclear. We examined the impact of nano-Newton forces on mitochondria using a bent optical fibre (BOF) with a flat-ended tip (diameter exceeding 2 μm) and a confocal fluorescence microscope. By indenting a single mitochondrion with the BOF tip, we found that the mitochondrial elastic modulus was proportional to the (-1/2) power of the mitochondrial radius in the 9.6-115 kPa range. We stained the mitochondria with a potential-metric dye (TMRE) and measured the changes in TMRE fluorescence intensity. We confirmed that more active mitochondria exhibit a higher frequency of repetitive transient depolarization. The same trend was observed at forces lower than 50 nN. We further showed that the depolarization frequency of mitochondria decreases under an extremely large force (nearly 100 nN). We conclude that mitochondrial function is affected by physical environmental factors, such as external forces at the nano-Newton level.

  6. CRYSTAL Simulation Code and New Coherent Effects in Bent Crystal at the LHC

    CERN Document Server

    Sytov, Alexei I

    2015-01-01

    The LHC crystal-based collimation system is mainly addressed. A CRYSTAL simulation code for particle tracking in crystals is introduced. Its essence consists in both adequate and fast sampling of proton trajectories in crystals which is crucial for both correct description of experiments and quantitative prediction of new effects. The H8 single-pass experiment at the CERN SPS as well as 7 TeV proton deflection by a bent crystal at the LHC are simulated. We predict the existence of dechanneling peaks corresponding to the planar channeling oscillations as well as describe the possibility of their observation at high energies, specifically in the LHC crystal-assisted collimation experiment planned on 2015. An effect of excess over the amorphous level of ionization losses in the channeling mode was also found for the LHC energy. In addition, the LHC crystal-based collimation system is simulated as well as its possible improved layouts with application of a crystal with the cut and multiple volume reflection in on...

  7. Recent evolution and degradation of the bent Jatunraju glacier (Cordillera Blanca, Peru)

    Science.gov (United States)

    Emmer, Adam; Loarte, Edwin C.; Klimeš, Jan; Vilímek, Vít

    2015-01-01

    This article brings new insight into the recent evolution and degradation of the bent Jatunraju glacier in the northern part of the Cordillera Blanca, Peru. Analysis of topographical maps, aerial photos and satellite images covering a period of 66 years and a field survey performed in June 2013 and May 2014 helped to describe the geomorphological setting and ongoing processes. Recent evolution and degradation processes are also deduced from surface movements. Historical geodetic measurements (1967-1968; 1977-1984) and current LANDSAT images (2001-2013) were used to estimate surface velocities and changes in surface velocities over time. Our investigation showed that the most significant changes happened at an altitude of between 4300 and 4450 m asl. A significant decrease in surface velocities and increase in debris thickness indicate that this part of Jatunraju turned from a debris-covered glacier into an ice-cored rock glacier during the analyzed period. Particular parts of the article describe the cycle of formation and extinction of supraglacial lakes and the melting of buried (debris-covered) ice. A scenario of future evolution is outlined and discussed as well. We assume that ice degradation within the debris-covered glacier will continue and that the altitude of its presence will increase hand-in-hand with the changing environment.

  8. Energy loss distributions of relativistic protons axially channeled in a bent silicon crystal

    Science.gov (United States)

    Stojanov, Nace; Petrović, Srdjan; Nešković, Nebojša

    2013-05-01

    A detailed study of the energy loss distributions of the relativistic protons axially channeled in the bent Si crystals is presented in this work. The bending angle was varied from 0 to 20 μrad, while the crystal thickness was equal to 1 mm. The proton energy was chosen to be 7 TeV in accordance with the Large Hadron Collider (LHC) project, at the European Organization for Nuclear Research (CERN), in Geneva, Switzerland. The energy loss distributions of the channeled protons were generated using the numerical solution of the proton equations of motion in the transverse plane and the computer simulation method. An accurate energy loss model was used, which takes into account the trajectory dependence of the energy loss of protons during their motion through the crystal channels. Further, the dispersion of the proton's scattering angle caused by its collisions with the electrons of the crystal and the divergence of the proton beam were taken into account. The calculated dependence of the number of dechanneled protons on the bending angle was excellently fitted by the Gompertz type dechanneling function.

  9. Energy loss distributions of relativistic protons axially channeled in a bent silicon crystal

    Energy Technology Data Exchange (ETDEWEB)

    Stojanov, Nace, E-mail: nacestoj@pmf.ukim.mk [Institute of Physics, Faculty of Natural Sciences and Mathematics, Sts. Cyril and Methodius University, P.O. Box 162, 1000 Skopje (Macedonia, The Former Yugoslav Republic of); Petrović, Srdjan; Nešković, Nebojša [Laboratory of Physics (010), Vinča Institute of Nuclear Sciences, University of Belgrade, P.O. Box 522, 11001 Belgrade (Serbia)

    2013-05-01

    A detailed study of the energy loss distributions of the relativistic protons axially channeled in the bent < 100 > Si crystals is presented in this work. The bending angle was varied from 0 to 20 μrad, while the crystal thickness was equal to 1 mm. The proton energy was chosen to be 7 TeV in accordance with the Large Hadron Collider (LHC) project, at the European Organization for Nuclear Research (CERN), in Geneva, Switzerland. The energy loss distributions of the channeled protons were generated using the numerical solution of the proton equations of motion in the transverse plane and the computer simulation method. An accurate energy loss model was used, which takes into account the trajectory dependence of the energy loss of protons during their motion through the crystal channels. Further, the dispersion of the proton’s scattering angle caused by its collisions with the electrons of the crystal and the divergence of the proton beam were taken into account. The calculated dependence of the number of dechanneled protons on the bending angle was excellently fitted by the Gompertz type dechanneling function.

  10. X-ray Imaging of MagLIF Experiments Using a Spherically-Bent Crystal Optic

    Science.gov (United States)

    Harding, E. C.; Gomez, M. R.; Jennings, C. A.; Knapp, P. F.; Slutz, S. A.; Sefkow, A. B.; Awe, T. J.; Hansen, S. B.; Peterson, K. J.; Hahn, K. D.; McBride, R. D.; Rochau, G. A.; Sinars, D. B.; Golovkin, I.

    2015-11-01

    The recent Magnetized Liner Inertial Fusion (MagLIF) experiments performed on Sandia's Z-machine produced significant thermonuclear DD fusion yields that were accompanied by observable x-ray emission [M.R. Gomez et. al., PRL (2014)]. The MagLIF experiments relied on a spherically-bent crystal optic to image portions of the x-ray continuum that were generated by the hot stagnation plasma. The images of stagnation show a long (6 to 8 mm) and narrow (~100 micron) column of x-ray emission with structure in both directions. This structure may be caused by variations in the electron temperature (Te) and density (ne) , as well as opacity variations in the surrounding Be pusher. Here we investigate the possible contributions from each of these effects. We will also discuss the development of a diagnostic technique in which Te and ne of the DD fuel are inferred from spectra emitted by Fe impurities that become ionized to a He-like charge state. Sandia National Labs is a multi-program laboratory managed and operated by Sandia Corporation, a wholly owned subsidiary of Lockheed Martin Corporation, for the U.S. DoE NNSA under contract DE-AC04-94AL85000.

  11. Theoretical study of bifurcated bent blue-shifted hydrogen bonds CH2…Y

    Institute of Scientific and Technical Information of China (English)

    2008-01-01

    Ab initio quantum chemistry methods were applied to study the bifurcated bent hydrogen bonds Y… H2CZ (Z = O, S, Se) and Y…H2CZ2 (Z = F, Cl, Br) (Y = Cl-, Br-) at the MP2/6-311++G(d,p) and MP2/6-311++G(2df,2p) levels. The results show that in each complex there are two equivalent blue-shifted H-bonds Y…H—C, and that the interaction energies and blue shifts are large, the energy of each Y…H—C H-bond is 15-27 kJ/mol, and Δr(CH) = -0.1 - -0.5 pm and Δv(CH) = 30 - 80 cm-1. The natural bond orbital analysis shows that these blue-shifted H-bonds are caused by three factors: large rehybridization; small direct intermolecular hyperconjugation and larger indirect intermolecular hy- perconjugation; large decrease of intramolecular hyperconjugation. The topological analysis of elec- tron density shows that in each complex there are three intermolecular critical points: there is one bond critical point between the acceptor atom Y and each hydrogen, and there is a ring critical point inside the tetragon YHCH, so these interactions are exactly H-bonding.

  12. Comparative results on collimation of the SPS beam of protons and Pb ions with bent crystals

    CERN Document Server

    Scandale, W.; Assmann, R.; Bracco, C.; Cerutti, F.; Christiansen, J.; Gilardoni, S.; Laface, E.; Losito, R.; Masi, A.; Metral, E.; Mirarchi, D.; Montesano, S.; Previtali, V.; Redaelli, S.; Valentino, G.; Schoofs, P.; Smirnov, G.; Tlustos, L.; Bagli, E.; Baricordi, S.; Dalpiaz, P.; Guidi, V.; Mazzolari, A.; Vincenzi, D.; Dabagov, S.; Murtas, F.; Carnera, A.; Della Mea, G.; De Salvador, D.; Lombardi, A.; Lytovchenko, O.; Tonezzer, M.; Cavoto, G.; Ludovici, L.; Santacesaria, R.; Valente, P.; Galluccio, F.; Afonin, A.G.; Bulgakov, M.K.; Chesnokov, Yu.A.; Maisheev, V.A.; Yazynin, I.A.; Kovalenko, A.D.; Taratin, A.M.; Uzhinskiy, V.V.; Gavrikov, Yu.A.; Ivanov, Yu.M.; Lapina, L.P.; Skorobogatov, V.V.; Ferguson, W.; Fulcher, J.; Hall, G.; Pesaresi, M.; Raymond, M.; Rose, A.; Ryan, M.; Zorba, O.; Robert-Demolaize, G.; Markiewicz, T.; Oriunno, M.; Wienands, U.

    2011-01-01

    New experiments on crystal assisted collimation have been carried out at the CERN SPS with stored beams of 120 Gev/c protons and Pb ions. Bent silicon crystals of 2 mm long with about 170 mu rad bend angle and a small residual torsion were used as primary collimators. In channeling conditions, the beam loss rate induced by inelastic interactions of particles with the crystal nuclei is minimal. The loss reduction was about 6 for protons and about 3 for Pb ions. Lower reduction value for Pb ions can be explained by their considerably larger ionization losses in the crystal. In one of the crystals, the measured fraction of the Pb ion beam halo deflected in channeling conditions was 74\\%, a value very close to that for protons. The intensity of the off-momentum halo leaking out from the collimation station was measured in the first high dispersion area downstream. The particle population in the shadow of the secondary collimator-absorber was considerably smaller in channeling conditions than for amorphous orienta...

  13. Record Deflection Efficiencies Measured for High Energy Protons in a Bent Germanium Crystal

    Science.gov (United States)

    Elsener, K.; Biino, C.; Clement, M.; Doble, N.; Gatignon, L.; Grafstrom, P.; Mikkelsen, U.; Kirsebom, K.; Møller, S. P.; Uggerhøj, E.; Worm, T.; Freund, A.

    1997-05-01

    New experimental results on the deflection of 450 GeV/c and 200 GeV/c protons in a bent Ge crystal are presented. At 450 GeV/c, the 50 mm long crystal gave record deflection efficiencies up to 60% for small angles (1 mrad), while at angles as large as 12 mrad, the efficiency is about 25 times larger than for a silicon crystal of the same size. Measurements up to 20 mrad deflection angle have been performed at 200 GeV/c as well as 450 GeV/c - the lower bending dechanneling leads to a rather slow decrease in efficiency at lower momenta, and 15% of the 200 GeV/c beam hitting the crystal are still deflected at the largest angles measured. These experimental results are in good agreement with a model for channeling deflection developed by Ellison and give confidence in extrapolations to higher energies (e.g. to LHC), other crystal materials or different deflection angles.

  14. Variance reduction techniques for 14 MeV neutron streaming problem in rectangular annular bent duct

    Energy Technology Data Exchange (ETDEWEB)

    Ueki, Kotaro [Ship Research Inst., Mitaka, Tokyo (Japan)

    1998-03-01

    Monte Carlo method is the powerful technique for solving wide range of radiation transport problems. Its features are that it can solve the Boltzmann`s transport equation almost without approximation, and that the complexity of the systems to be treated rarely becomes a problem. However, the Monte Carlo calculation is always accompanied by statistical errors called variance. In shielding calculation, standard deviation or fractional standard deviation (FSD) is used frequently. The expression of the FSD is shown. Radiation shielding problems are roughly divided into transmission through deep layer and streaming problem. In the streaming problem, the large difference in the weight depending on the history of particles makes the FSD of Monte Carlo calculation worse. The streaming experiment in the 14 MeV neutron rectangular annular bent duct, which is the typical streaming bench mark experiment carried out of the OKTAVIAN of Osaka University, was analyzed by MCNP 4B, and the reduction of variance or FSD was attempted. The experimental system is shown. The analysis model by MCNP 4B, the input data and the results of analysis are reported, and the comparison with the experimental results was examined. (K.I.)

  15. Whole-body muscle MRI to detect myopathies in non-extrapyramidal bent spine syndrome

    Energy Technology Data Exchange (ETDEWEB)

    Ohana, Mickael [Nouvel Hopital Civil - Hopitaux Universitaires de Strasbourg, Service de Radiologie B, Strasbourg (France); Durand, Marie-Christine [AP-HP - Hopital Raymond Poincare, Service de Neurologie, Garches (France); Marty, Catherine; Lazareth, Jean-Philippe [AP-HP - Hopital Raymond Poincare, Service de Rhumatologie, Garches (France); Maisonobe, Thierry [APH-HP - Hopital de la Pitie-Salpetriere, Service de Neuropathologie, Paris (France); Mompoint, Dominique; Carlier, Robert-Yves [AP-HP - Hopital Raymond Poincare, Service de Radiologie, Garches (France)

    2014-08-15

    Bent spine syndrome (BSS), defined as an abnormal forward flexion of the trunk resolving in supine position, is usually related to parkinsonism, but can also be encountered in myopathies. This study evaluates whole-body muscle MRI (WB-mMRI) as a tool for detecting underlying myopathy in non-extrapyramidal BSS. Forty-three patients (90 % women; 53-86 years old) with a non-extrapyramidal BSS were prospectively included. All underwent a 1.5-T WB-mMRI and a nerve conduction study. Muscle biopsy was performed if a myopathy could not be eliminated based on clinical examination and all tests. Systematic MRI interpretation focused on peripheral and axial muscle injury; spinal posture and incidental findings were also reported. WB-mMRI was completed for all patients, with 13 muscle biopsies ultimately needed and myopathy revealed as the final etiological diagnosis in five cases (12 %). All biopsy-proven myopathies were detected by the WB-mMRI. Relevant incidental MRI findings were made in seven patients. This study supports WB-mMRI as a sensitive and feasible tool for detecting myopathy in BSS patients. Associated with electroneuromyography, it can better indicate when a muscle biopsy is needed and guide it when required. Rigorous radiological interpretation is mandatory, so as not to miss incidental findings of clinical consequence. (orig.)

  16. Optimization and Annual Average Power Predictions of a Backward Bent Duct Buoy Oscillating Water Column Device Using the Wells Turbine

    OpenAIRE

    Smith, Christopher; Willits, Steven; Bull, Diana; Fontaine, Arnold

    2014-01-01

    This paper presents work completed by The Applied Research Laboratory at The Pennsylvania State University, in conjunction with Sandia National Labs, on the optimization of the power conversion chain (PCC) design to maximize the Average Annual Electric Power (AAEP) output of an Oscillating Water Column (OWC) device. The design consists of two independent stages. First, the design of a floating OWC, a Backward Bent Duct Buoy (BBDB), and second the design of the PCC. The pneumatic power output ...

  17. Existence of polar switching in the nematic and orthogonal smectic phases in novel four-ring bent-core compounds

    Science.gov (United States)

    Turlapati, Srikanth; Khan, Raj Kumar; Ghosh, Sharmistha; Tadapatri, Pramod; Pratibha, R.; Rao, Nandiraju V. S.

    2016-11-01

    Bent-core liquid crystals have set the first example of forming polar superstructures from achiral molecules. Polar switching studies in smectic phases have revealed several exciting sub-phases which have never been observed in rod-like liquid crystals. In this study, mesomorphic and polar switching properties of three bent-core compounds belonging to a homologous series have been investigated using polarizing optical microscopy (POM), differential scanning calorimetry, XRD studies, electro-optics, and dielectric spectroscopy. These achiral, unsymmetrical four-ring bent-core liquid crystals with a polar fluoro substituent at one end and n-alkoxy chain at the other terminal end possess azo, ester, and imine linkages between the four phenyl rings and different lateral substituents. The compounds 16-F and 18-F exhibit orthogonal smectic phase with antiferroelectric polar order, and additionally, the compound 16-F exhibits a short range nematic phase with a polar order. The compound 7-F exhibits broad enantiotropic nematic mesomorphism without appearance of any smectic ordering at low temperature. The smectic and nematic phases were identified by their optical textures observed by POM. Distinct polarization current peaks under triangular wave voltage are observed for all the compounds in the entire mesophase range. Relaxation phenomena corresponding to polar associations of the molecules are observed in dielectric spectroscopy. The cybotactic nature of the nematic phase is established by the XRD and electro-optic studies of 16-F. Although it is rather difficult to form mesophase when the number of aromatic rings is reduced from five, we have successfully demonstrated the bent-core compounds with four-ring which exhibit orthogonal smectic phases as well as nematic mesomorphism with unusual cybotactic signature.

  18. Deflection of 32.8 TeV/c fully stripped Pb ions by means of a bent Si crystal

    CERN Document Server

    Biino, C; Doble, Niels T; Elsener, K; Gatignon, L; Grafström, P; Herr, Werner; Keppler, P; Major, J V; Mikkelsen, U; Taratin, A; Velasco, M

    2000-01-01

    New results on the deflection of fully stripped 32.8 TeV/c Pb ions in a bent Si crystal at the CERN-SPS are reported. Deflection efficiencies above 10% have been measured for deflection angles in the range 4-9 mrad.The effect of particle losses due to interaction in the crystal and other systematic errors have been carefully investigated. The experimental results are in agreement with theoretical calculations

  19. Deflection of 32.8 TeV/c fully stripped Pb ions by means of a bent Si crystal

    Energy Technology Data Exchange (ETDEWEB)

    Biino, C.; Clement, M.; Doble, N.; Elsener, K. E-mail: konrad.elsener@cern.ch; Gatignon, L.; Grafstroem, P.; Herr, W.; Keppler, P.; Major, J.; Mikkelsen, U.; Taratin, A.; Velasco, M

    2000-04-01

    New results on the deflection of fully stripped 32.8 TeV/c Pb ions in a bent Si crystal at the CERN-SPS are reported. Deflection efficiencies above 10% have been measured for deflection angles in the range 4-9 mrad. The effect of particle losses due to interaction in the crystal and other systematic errors have been carefully investigated. The experimental results are in agreement with theoretical calculations.

  20. Deflection of 32.8 TeV/c fully stripped Pb ions by means of a bent Si crystal

    Science.gov (United States)

    Biino, C.; Clément, M.; Doble, N.; Elsener, K.; Gatignon, L.; Grafström, P.; Herr, W.; Keppler, P.; Major, J.; Mikkelsen, U.; Taratin, A.; Velasco, M.

    2000-03-01

    New results on the deflection of fully stripped 32.8 TeV/c Pb ions in a bent Si crystal at the CERN-SPS are reported. Deflection efficiencies above 10% have been measured for deflection angles in the range 4-9 mrad. The effect of particle losses due to interaction in the crystal and other systematic errors have been carefully investigated. The experimental results are in agreement with theoretical calculations.