WorldWideScience

Sample records for grip force profile

  1. Adjustment of gripping force by optical systems

    Science.gov (United States)

    Jalba, C. K.; Barz, C.

    2018-01-01

    With increasing automation, robotics also requires ever more intelligent solutions in the handling of various tasks. In this context, many grippers must also be re-designed. For this, they must always be adapted for different requirements. The equipment of the gripper systems with sensors should help to make the gripping process more intelligent. In order to achieve such objectives, optical systems can also be used. This work analyzes how the gripping force can be adjusted by means of an optical recognition. The result of this work is the creation of a connection between optical recognition, tolerances, gripping force and real-time control. In this way, algorithms can be created, with the aid of which robot grippers as well as other gripping systems become more intelligent.

  2. ASSESSMENT OF GRIP FORCE CONTROL IN PATIENTS WITH MUSCULAR DYSTROPHY

    Directory of Open Access Journals (Sweden)

    Gregorij Kurillo

    2004-12-01

    Full Text Available Background. The majority of hand functionality tests are based on qualitative assessment which largely depends on the experience of the therapist. Computer-assisted methods can provide more objective and accurate measurements of the grip force and other parameters related to grasping.Methods. We analysed the grip force control in 12 patients with muscular dystrophy using the tracking system developed. The system consists of a grip-measuring device with endobjects assessing the force applied in different grips. The device was used as input to a tracking task where the patient applied the grip force according to the visual feedback from the computer screen. Each patient performed two tasks which consisted of tracking a ramp and sinus target.Results. We analysed the maximal grip force as assessed in the ramp task and the tracking accuracy of the sinus task. The results are compared among five different grips (cylindrical, lateral, palmar, pinch and spherical grip, applied with dominant and non-dominant hand. The results show no significant difference in tracking accuracy between the dominant and non-dominant hand.Conclusions. The results obtained in tracking the ramp target showed that the method could be used for the assessment of the muscle fatigue, providing quantitative information on muscle capacity. The results of the sinus-tracking task showed that the method can evaluate the grip force control in different types of grips, providing information on hand dexterity, muscle activation patterns or tremor.

  3. Differences in grip force control between young and late middle-aged adults.

    Science.gov (United States)

    Zheng, Lianrong; Li, Kunyang; Wang, Qian; Chen, Wenhui; Song, Rong; Liu, Guanzheng

    2017-09-01

    Grip force control is a crucial function for human to guarantee the quality of life. To examine the effects of age on grip force control, 10 young adults and 11 late middle-aged adults participated in visually guided tracking tasks using different target force levels (25, 50, and 75% of the subject's maximal grip force). Multiple measures were used to evaluate the tracking performance during force rising phase and force maintenance phase. The measurements include the rise time, fuzzy entropy, mean force percentage, coefficient of variation, and target deviation ratio. The results show that the maximal grip force was significantly lower in the late middle-aged adults than in the young adults. The time of rising phase was systematically longer among late middle-aged adults. The fuzzy entropy is a useful indicator for quantitating the force variability of the grip force signal at higher force levels. These results suggest that the late middle-aged adults applied a compensatory strategy that allow allows for sufficient time to reach the required grip force and reduce the impact of the early and subtle degenerative changes in hand motor function.

  4. The effect of force feedback delay on stiffness perception and grip force modulation during tool-mediated interaction with elastic force fields.

    Science.gov (United States)

    Leib, Raz; Karniel, Amir; Nisky, Ilana

    2015-05-01

    During interaction with objects, we form an internal representation of their mechanical properties. This representation is used for perception and for guiding actions, such as in precision grip, where grip force is modulated with the predicted load forces. In this study, we explored the relationship between grip force adjustment and perception of stiffness during interaction with linear elastic force fields. In a forced-choice paradigm, participants probed pairs of virtual force fields while grasping a force sensor that was attached to a haptic device. For each pair, they were asked which field had higher level of stiffness. In half of the pairs, the force feedback of one of the fields was delayed. Participants underestimated the stiffness of the delayed field relatively to the nondelayed, but their grip force characteristics were similar in both conditions. We analyzed the magnitude of the grip force and the lag between the grip force and the load force in the exploratory probing movements within each trial. Right before answering which force field had higher level of stiffness, both magnitude and lag were similar between delayed and nondelayed force fields. These results suggest that an accurate internal representation of environment stiffness and time delay was used for adjusting the grip force. However, this representation did not help in eliminating the bias in stiffness perception. We argue that during performance of a perceptual task that is based on proprioceptive feedback, separate neural mechanisms are responsible for perception and action-related computations in the brain. Copyright © 2015 the American Physiological Society.

  5. Grip Force Adjustments Reflect Prediction of Dynamic Consequences in Varying Gravitoinertial Fields

    Directory of Open Access Journals (Sweden)

    Olivier White

    2018-02-01

    Full Text Available Humans have a remarkable ability to adjust the way they manipulate tools through a genuine regulation of grip force according to the task. However, rapid changes in the dynamical context may challenge this skill, as shown in many experimental approaches. Most experiments adopt perturbation paradigms that affect only one sensory modality. We hypothesize that very fast adaptation can occur if coherent information from multiple sensory modalities is provided to the central nervous system. Here, we test whether participants can switch between different and never experienced dynamical environments induced by centrifugation of the body. Seven participants lifted an object four times in a row successively in 1, 1.5, 2, 2.5, 2, 1.5, and 1 g. We continuously measured grip force, load force and the gravitoinertial acceleration that was aligned with body axis (perceived gravity. Participants adopted stereotyped grasping movements immediately upon entry in a new environment and needed only one trial to adapt grip forces to a stable performance in each new gravity environment. This result was underlined by good correlations between grip and load forces in the first trial. Participants predictively applied larger grip forces when they expected increasing gravity steps. They also decreased grip force when they expected decreasing gravity steps, but not as much as they could, indicating imperfect anticipation in that condition. The participants' performance could rather be explained by a combination of successful scaling of grip force according to gravity changes and a separate safety factor. The data suggest that in highly unfamiliar dynamic environments, grip force regulation is characterized by a combination of a successful anticipation of the experienced environmental condition, a safety factor reflecting strategic response to uncertainties about the environment and rapid feedback mechanisms to optimize performance under constant conditions.

  6. Deficits of anticipatory grip force control after damage to peripheral and central sensorimotor systems.

    Science.gov (United States)

    Hermsdörfer, Joachim; Hagl, Elke; Nowak, Dennis A

    2004-11-01

    Healthy subjects adjust their grip force economically to the weight of a hand-held object. In addition, inertial loads, which arise from arm movements with the grasped object, are anticipated by parallel grip force modulations. Internal forward models have been proposed to predict the consequences of voluntary movements. Anesthesia of the fingers impairs grip force economy but the feedforward character of the grip force/load coupling is preserved. To further analyze the role of sensory input for internal forward models and to characterize the consequences of central nervous system damage for anticipatory grip force control, we measured grip force behavior in neurological patients. We tested a group of stroke patients with varying degrees of impaired fine motor control and sensory loss, a single patient with complete and permanent differentation from all tactile and proprioceptive input, and a group of patients with amyotrophic lateral sclerosis (ALS) that exclusively impairs the motor system without affecting sensory modalities. Increased grip forces were a common finding in all patients. Sensory deficits were a strong but not the only predictor of impaired grip force economy. The feedforward mode of grip force control was typically preserved in the stroke patients despite their central sensory deficits, but was severely disturbed in the patient with peripheral sensory deafferentation and in a minority of stroke patients. Moderate deficits of feedforward control were also obvious in ALS patients. Thus, the function of the internal forward model and the precision of grip force production may depend on a complex anatomical and functional network of sensory and motor structures and their interaction in time and space.

  7. Inertial torque during reaching directly impacts grip-force adaptation to weightless objects.

    Science.gov (United States)

    Giard, T; Crevecoeur, F; McIntyre, J; Thonnard, J-L; Lefèvre, P

    2015-11-01

    A hallmark of movement control expressed by healthy humans is the ability to gradually improve motor performance through learning. In the context of object manipulation, previous work has shown that the presence of a torque load has a direct impact on grip-force control, characterized by a significantly slower grip-force adjustment across lifting movements. The origin of this slower adaptation rate remains unclear. On the one hand, information about tangential constraints during stationary holding may be difficult to extract in the presence of a torque. On the other hand, inertial torque experienced during movement may also potentially disrupt the grip-force adjustments, as the dynamical constraints clearly differ from the situation when no torque load is present. To address the influence of inertial torque loads, we instructed healthy adults to perform visually guided reaching movements in weightlessness while holding an unbalanced object relative to the grip axis. Weightlessness offered the possibility to remove gravitational constraints and isolate the effect of movement-related feedback on grip force adjustments. Grip-force adaptation rates were compared with a control group who manipulated a balanced object without any torque load and also in weightlessness. Our results clearly show that grip-force adaptation in the presence of a torque load is significantly slower, which suggests that the presence of torque loads experienced during movement may alter our internal estimates of how much force is required to hold an unbalanced object stable. This observation may explain why grasping objects around the expected location of the center of mass is such an important component of planning and control of manipulation tasks.

  8. Hand-grip isometric strength in judo

    Directory of Open Access Journals (Sweden)

    Juan G Bonitch-Góngora

    2014-02-01

    Full Text Available The grip is an important technical and tactical aspect through which the judokas dominate the adversary, hindering the application of appropriate techniques and favoring their own attack. The judokas must have high levels of isometric force and endurance to this type of force on the gripping muscles of the forearms, as one of the key aspects for success. This article reviews the grip muscular strength and endurance profiles of judokas of different groups (gender, age and competitive level. In general, the peak isometric strength of elite judokas has not changed in the last 40 years and is similar to that reached by non-elite judokas or even registered in large populations. This indicate that the evaluation of the isometric hand grip endurance may be a more relevant parameter than the peak isometric force in judokas, as during the bouts the grip must be maintained for relatively long periods of time and the maximum force cannot be maintained for long. However there are few studies on the ability to resist successive isometric handgrip stress in judokas.

  9. Probabilistic information on object weight shapes force dynamics in a grip-lift task.

    Science.gov (United States)

    Trampenau, Leif; Kuhtz-Buschbeck, Johann P; van Eimeren, Thilo

    2015-06-01

    Advance information, such as object weight, size and texture, modifies predictive scaling of grip forces in a grip-lift task. Here, we examined the influence of probabilistic advance information about object weight. Fifteen healthy volunteers repeatedly grasped and lifted an object equipped with a force transducer between their thumb and index finger. Three clearly distinguishable object weights were used. Prior to each lift, the probabilities for the three object weights were given by a visual cue. We examined the effect of probabilistic pre-cues on grip and lift force dynamics. We expected predictive scaling of grip force parameters to follow predicted values calculated according to probabilistic contingencies of the cues. We observed that probabilistic cues systematically influenced peak grip and load force rates, as an index of predictive motor scaling. However, the effects of probabilistic cues on force rates were nonlinear, and anticipatory adaptations of the motor output generally seemed to overestimate high probabilities and underestimate low probabilities. These findings support the suggestion that anticipatory adaptations and force scaling of the motor system can integrate probabilistic information. However, probabilistic information seems to influence motor programs in a nonlinear fashion.

  10. The brain adjusts grip forces differently according to gravity and inertia: a parabolic flight experiment

    Directory of Open Access Journals (Sweden)

    Olivier eWhite

    2015-02-01

    Full Text Available In everyday life, one of the most frequent activities involves accelerating and decelerating an object held in precision grip. In many contexts, humans scale and synchronize their grip force, normal to the finger/object contact, in anticipation of the expected tangential load force, resulting from the combination of the gravitational and the inertial forces. In many contexts, grip force and load force are linearly coupled. A few studies have examined how we adjust the parameters - gain and offset - of this linear relationship. However, the question remains open as to how the brain adjusts grip force regardless of whether load force is generated by different combinations of weight and inertia. Here, we designed conditions to generate equivalent magnitudes of load force by independently varying mass and movement frequency. In a control experiment, we directly manipulated gravity in parabolic flights, while other factors remained constant. We show with a simple computational approach that, to adjust grip force, the brain is sensitive to how load forces are produced at the fingertips. This provides clear evidence that the analysis of the origin of load force is performed centrally, and not only at the periphery.

  11. Contribution of the Cerebellum in Cue-Dependent Force Changes During an Isometric Precision Grip Task.

    Science.gov (United States)

    Kutz, Dieter F; Schmid, Barbara C; Meindl, Tobias; Timmann, Dagmar; Kolb, Florian P

    2016-08-01

    The "raspberry task" represents a precision grip task that requires continuous adjustment of grip forces and pull forces. During this task, subjects use a specialised grip rod and have to increase the pull force linearly while the rod is locked. The positions of the fingers are unrestrained and freely selectable. From the finger positions and the geometry of the grip rod, a physical lever was derived which is a comprehensive measurement of the subject's grip behaviour. In this study, the involvement of the cerebellum in establishing cued force changes (CFC) was examined. The auditory stimulus was associated with a motor behaviour that has to be readjusted during an ongoing movement that already started. Moreover, cerebellar involvement on grip behaviour was examined. The results show that patients presenting with degenerating cerebellar disease (CBL) were able to elicit CFC and were additionally able to optimise grip behaviour by minimising the lever. Comparison of the results of CBL with a control group of healthy subjects showed, however, that the CFC incidence was significantly lower and the reduction of the lever was less in CBL. Hence, the cerebellum is involved not only in the classical conditioning of reflexes but also in the association of sensory stimuli with complex changes in motor behaviour. Furthermore, the cerebellum is involved in the optimisation of grip behaviour during ongoing movements. Recent studies lead to the assumption that the cerebello-reticulo-spinal pathway might be important for the reduced optimisation of grip behaviour in CBL.

  12. The properties and interrelationships of various force-time parameters during maximal repeated rhythmic grip.

    Science.gov (United States)

    Nakada, Masakatsu; Demura, Shinichi; Yamaji, Shunsuke

    2007-01-01

    The purpose of this study was to examine the properties and interrelationships of various force-time parameters including the inflection point for the rate of decline in force during a maximal repeated rhythmic grip. Fifteen healthy males (age M=21.5, SD=2.1 yr, height M=172.4, SD=5.7 cm, body mass M=68.2, SD=9.2 kg) participated in this study. Subjects performed a maximal repeated rhythmic grip with maximal effort with a target frequency of 30 grip.min(-1) for 6 min. The force value decreased linearly and markedly until about 70% of maximal strength for about 55 s after the onset of a maximal repeated rhythmic grip, and then decreased moderately. Because all parameters showed fair or good correlations between 3 min and 6 min, they are considered to be able to sufficiently evaluate muscle endurance for 3 min instead of 6 min. However, there were significant differences between 3 min and 6 min in the integrated area, the final force, the rate of the decrement constant (k) fitting the force decreasing data to y=ae(-kx)+b and the force of maximal difference between the force and a straight line from peak force to the final force. Their parameters may vary generally by the length of a steady state, namely, a measurement time. The final force value before finishing and the rate of the decrement constant (k) reflect the latter phase during a maximal repeated rhythmic grip. Although many parameters show relatively high mutual relationships, the rate constant (k) shows relatively low correlations with other parameters. We inferred that decreasing the time until 80% of maximal strength and the amount of the decrement force for the first 1 min reflect a linear decrease in the initial phase.

  13. Fitts’ Law in the Control of Isometric Grip Force With Naturalistic Targets

    Directory of Open Access Journals (Sweden)

    Zachary C. Thumser

    2018-04-01

    Full Text Available Fitts’ law models the relationship between amplitude, precision, and speed of rapid movements. It is widely used to quantify performance in pointing tasks, study human-computer interaction, and generally to understand perceptual-motor information processes, including research to model performance in isometric force production tasks. Applying Fitts’ law to an isometric grip force task would allow for quantifying grasp performance in rehabilitative medicine and may aid research on prosthetic control and design. We examined whether Fitts’ law would hold when participants attempted to accurately produce their intended force output while grasping a manipulandum when presented with images of various everyday objects (we termed this the implicit task. Although our main interest was the implicit task, to benchmark it and establish validity, we examined performance against a more standard visual feedback condition via a digital force-feedback meter on a video monitor (explicit task. Next, we progressed from visual force feedback with force meter targets to the same targets without visual force feedback (operating largely on feedforward control with tactile feedback. This provided an opportunity to see if Fitts’ law would hold without vision, and allowed us to progress toward the more naturalistic implicit task (which does not include visual feedback. Finally, we changed the nature of the targets from requiring explicit force values presented as arrows on a force-feedback meter (explicit targets to the more naturalistic and intuitive target forces implied by images of objects (implicit targets. With visual force feedback the relation between task difficulty and the time to produce the target grip force was predicted by Fitts’ law (average r2 = 0.82. Without vision, average grip force scaled accurately although force variability was insensitive to the target presented. In contrast, images of everyday objects generated more reliable grip forces

  14. Fitts' Law in the Control of Isometric Grip Force With Naturalistic Targets.

    Science.gov (United States)

    Thumser, Zachary C; Slifkin, Andrew B; Beckler, Dylan T; Marasco, Paul D

    2018-01-01

    Fitts' law models the relationship between amplitude, precision, and speed of rapid movements. It is widely used to quantify performance in pointing tasks, study human-computer interaction, and generally to understand perceptual-motor information processes, including research to model performance in isometric force production tasks. Applying Fitts' law to an isometric grip force task would allow for quantifying grasp performance in rehabilitative medicine and may aid research on prosthetic control and design. We examined whether Fitts' law would hold when participants attempted to accurately produce their intended force output while grasping a manipulandum when presented with images of various everyday objects (we termed this the implicit task). Although our main interest was the implicit task, to benchmark it and establish validity, we examined performance against a more standard visual feedback condition via a digital force-feedback meter on a video monitor (explicit task). Next, we progressed from visual force feedback with force meter targets to the same targets without visual force feedback (operating largely on feedforward control with tactile feedback). This provided an opportunity to see if Fitts' law would hold without vision, and allowed us to progress toward the more naturalistic implicit task (which does not include visual feedback). Finally, we changed the nature of the targets from requiring explicit force values presented as arrows on a force-feedback meter (explicit targets) to the more naturalistic and intuitive target forces implied by images of objects (implicit targets). With visual force feedback the relation between task difficulty and the time to produce the target grip force was predicted by Fitts' law (average r 2 = 0.82). Without vision, average grip force scaled accurately although force variability was insensitive to the target presented. In contrast, images of everyday objects generated more reliable grip forces without the visualized

  15. Adaptive grip force is modulated by subthalamic beta activity in Parkinson's disease patients

    Directory of Open Access Journals (Sweden)

    Lukas L. Imbach

    2015-01-01

    Conclusion: The time-locked suppression of beta oscillatory activity in the STN is in line with previous reports of beta ERD prior to voluntary movements. Our results show that the STN is involved in anticipatory grip force control in PD patients. The difference in the phasic beta ERD between the two tasks and the reduction of cortico-subthalamic synchronization suggests that qualitatively different neuronal network states are involved in different grip force control tasks.

  16. Computational model of precision grip in Parkinson’s disease: A Utility based approach

    Directory of Open Access Journals (Sweden)

    Ankur eGupta

    2013-12-01

    Full Text Available We propose a computational model of Precision Grip (PG performance in normal subjects and Parkinson’s Disease (PD patients. Prior studies on grip force generation in PD patients show an increase in grip force during ON medication and an increase in the variability of the grip force during OFF medication (Fellows et al 1998; Ingvarsson et al 1997. Changes in grip force generation in dopamine-deficient PD conditions strongly suggest contribution of the Basal Ganglia, a deep brain system having a crucial role in translating dopamine signals to decision making. The present approach is to treat the problem of modeling grip force generation as a problem of action selection, which is one of the key functions of the Basal Ganglia. The model consists of two components: 1 the sensory-motor loop component, and 2 the Basal Ganglia component. The sensory-motor loop component converts a reference position and a reference grip force, into lift force and grip force profiles, respectively. These two forces cooperate in grip-lifting a load. The sensory-motor loop component also includes a plant model that represents the interaction between two fingers involved in PG, and the object to be lifted. The Basal Ganglia component is modeled using Reinforcement Learning with the significant difference that the action selection is performed using utility distribution instead of using purely Value-based distribution, thereby incorporating risk-based decision making. The proposed model is able to account for the precision grip results from normal and PD patients accurately (Fellows et. al. 1998; Ingvarsson et. al. 1997. To our knowledge the model is the first model of precision grip in PD conditions.

  17. Investigation of index finger triggering force using a cadaver experiment: Effects of trigger grip span, contact location, and internal tendon force.

    Science.gov (United States)

    Chang, Joonho; Freivalds, Andris; Sharkey, Neil A; Kong, Yong-Ku; Mike Kim, H; Sung, Kiseok; Kim, Dae-Min; Jung, Kihyo

    2017-11-01

    A cadaver study was conducted to investigate the effects of triggering conditions (trigger grip span, contact location, and internal tendon force) on index finger triggering force and the force efficiency of involved tendons. Eight right human cadaveric hands were employed, and a motion simulator was built to secure and control the specimens. Index finger triggering forces were investigated as a function of different internal tendon forces (flexor digitorum profundus + flexor digitorum superficialis = 40, 70, and 100 N), trigger grip spans (40, 50, and 60 mm), and contact locations between the index finger and a trigger. Triggering forces significantly increased when internal tendon forces increased from 40 to 100 N. Also, trigger grip spans and contact locations had significant effects on triggering forces; maximum triggering forces were found at a 50 mm span and the most proximal contact location. The results revealed that only 10-30% of internal tendon forces were converted to their external triggering forces. Copyright © 2017 Elsevier Ltd. All rights reserved.

  18. An Overview on Gripping Force Measurement at the Micro and Nano-Scales Using Two-Fingered Microrobotic Systems

    Directory of Open Access Journals (Sweden)

    Mokrane Boudaoud

    2014-03-01

    Full Text Available Two-fingered micromanipulation systems with an integrated force sensor are widely used in robotics to sense and control gripping forces at the micro and nano-scales. They became of primary importance for an efficient manipulation and characterization of highly deformable biomaterials and nanostructures. This paper presents a chronological overview of gripping force measurement using two-fingered micromanipulation systems. The work summarizes the major achievements in this field from the early 90s to the present, focusing in particular on the evolution of measurement technologies regarding the requirements of microrobotic applications. Measuring forces below the microNewton for the manipulation of highly deformable materials, embedding force sensors within microgrippers to increase their dexterity, and reducing the influence of noise to improve the measurement resolution are among the addressed challenges. The paper shows different examples of how these challenges have been addressed. Resolution, operating range and signal/noise ratio of gripping force sensors are reported and compared. A discussion about force measurement technologies and gripping force control is performed and future trends are highlighted.

  19. Phalanx force magnitude and trajectory deviation increased during power grip with an increased coefficient of friction at the hand-object interface.

    Science.gov (United States)

    Enders, Leah R; Seo, Na Jin

    2011-05-17

    This study examined the effect of friction between the hand and grip surface on a person's grip strategy and force generation capacity. Twelve young healthy adults performed power grip exertions on an instrumented vertical cylinder with the maximum and 50% of maximum efforts (far above the grip force required to hold the cylinder), while normal and shear forces at each phalanx of all five fingers in the direction orthogonal to the gravity were recorded. The cylinder surface was varied for high-friction rubber and low-friction paper coverings. An increase in surface friction by replacing the paper covering with the rubber covering resulted in 4% greater mean phalanx normal force (perpendicular to the cylinder surface) and 22% greater mean phalanx shear force in either the proximal or distal direction of the digits (pfriction with the rubber surface compared to the paper surface was associated with a 20% increase in the angular deviation of the phalanx force from the direction normal to the cylinder surface (p<0.05). This study demonstrates that people significantly changed the magnitude and direction of phalanx forces depending on the surface they gripped. Such change in the grip strategy appears to help increase grip force generation capacity. This finding suggests that a seemingly simple power grip exertion involves sensory feedback-based motor control, and that people's power grip capacity may be reduced in cases of numbness, glove use, or injuries resulting in reduced sensation. Copyright © 2011 Elsevier Ltd. All rights reserved.

  20. Quantification of hand function by power grip and pinch strength force measurements in ulnar nerve lesion simulated by ulnar nerve block.

    Science.gov (United States)

    Wachter, Nikolaus Johannes; Mentzel, Martin; Krischak, Gert D; Gülke, Joachim

    2017-06-24

    In the assessment of hand and upper limb function, grip strength is of the major importance. The measurement by dynamometers has been established. In this study, the effect of a simulated ulnar nerve lesion on different grip force measurements was evaluated. In 25 healthy volunteers, grip force measurement was done by the JAMAR dynamometer (Fabrication Enterprises Inc, Irvington, NY) for power grip and by a pinch strength dynamometer for tip pinch strength, tripod grip, and key pinch strength. A within-subject research design was used in this prospective study. Each subject served as the control by preinjection measurements of grip and pinch strength. Subsequent measurements after ulnar nerve block were used to examine within-subject change. In power grip, there was a significant reduction of maximum grip force of 26.9% with ulnar nerve block compared with grip force without block (P force could be confirmed. However, the assessment of other dimensions of hand strength as tip pinch, tripod pinch and key pinch had more relevance in demonstrating hand strength changes resulting from an distal ulnar nerve lesion. The measurement of tip pinch, tripod grip and key pinch can improve the follow-up in hand rehabilitation. II. Copyright © 2017 Hanley & Belfus. Published by Elsevier Inc. All rights reserved.

  1. An exploration of grip force regulation with a low-impedance myoelectric prosthesis featuring referred haptic feedback.

    Science.gov (United States)

    Brown, Jeremy D; Paek, Andrew; Syed, Mashaal; O'Malley, Marcia K; Shewokis, Patricia A; Contreras-Vidal, Jose L; Davis, Alicia J; Gillespie, R Brent

    2015-11-25

    Haptic display technologies are well suited to relay proprioceptive, force, and contact cues from a prosthetic terminal device back to the residual limb and thereby reduce reliance on visual feedback. The ease with which an amputee interprets these haptic cues, however, likely depends on whether their dynamic signal behavior corresponds to expected behaviors-behaviors consonant with a natural limb coupled to the environment. A highly geared motor in a terminal device along with the associated high back-drive impedance influences dynamic interactions with the environment, creating effects not encountered with a natural limb. Here we explore grasp and lift performance with a backdrivable (low backdrive impedance) terminal device placed under proportional myoelectric position control that features referred haptic feedback. We fabricated a back-drivable terminal device that could be used by amputees and non-amputees alike and drove aperture (or grip force, when a stiff object was in its grasp) in proportion to a myoelectric signal drawn from a single muscle site in the forearm. In randomly ordered trials, we assessed the performance of N=10 participants (7 non-amputee, 3 amputee) attempting to grasp and lift an object using the terminal device under three feedback conditions (no feedback, vibrotactile feedback, and joint torque feedback), and two object weights that were indiscernible by vision. Both non-amputee and amputee participants scaled their grip force according to the object weight. Our results showed only minor differences in grip force, grip/load force coordination, and slip as a function of sensory feedback condition, though the grip force at the point of lift-off for the heavier object was significantly greater for amputee participants in the presence of joint torque feedback. An examination of grip/load force phase plots revealed that our amputee participants used larger safety margins and demonstrated less coordination than our non-amputee participants

  2. Anticipatory grip force between 1 and 3g

    Science.gov (United States)

    White, Olivier; Van Loon, ing.. Jack J. W. A.; Thonnard, Jean-Louis; Hermsdorfer, Joachim; Lefevre, Philippe

    One remarkable capacity of utilizing common tools appropriately as soon as we grasp them relies on the ability to determine in advance the grip force (GF) required to handle them in relation to their mechanical properties and the surrounding environment. This anticipatory strategy avoids the uncompressible delays in the feedback system. The predictive control of GF is made possible because the nervous system can learn, store and then select the internal representations of the dynamics of innumerable objects, known as internal models. Beside this flexibility, the nervous system's ability to learn different task dynamics is often limited in classical robotic experiments The environment itself can be profoundly modified in altered gravity or centrifugation. The few studies that investigated motor adaptation in such contexts did not consider the interaction between gravitational phases and even less the transitions across environments. Here, we tested subject's abilities to adapt to levels of gravitational fields generated by a human centrifuge. In Experiment 1, seven subjects performed 4 lifting trials in each gravitational phase (1 to 2.5g and then 2.5 to 1g by steps of 0.5g) with a 0.12 kg instrumented object. In Experiment 2, six subjects performed vertical oscillations of the object during transitions between 1 and 3g (0.5g steps, ascending and descending phases, profile repeated twice). We continuously measured GF, load force (LF) and ambient gravity. We hypothesized that participants were able to predictively adjust GF to the new environment. In Experiment 1, participants adjusted their GF proportionally to gravity and decreased GF across trials within a given gravitational environment. Preload phases decreased over time from 300ms to 50ms irrespective of gravity. We quantified the abilities of participants to switch across environments by subtracting GF recorded in the last trial in the current gravity level from GF during the first trial in the new environment

  3. Grip Force and 3D Push-Pull Force Estimation Based on sEMG and GRNN

    Directory of Open Access Journals (Sweden)

    Changcheng Wu

    2017-06-01

    Full Text Available The estimation of the grip force and the 3D push-pull force (push and pull force in the three dimension space from the electromyogram (EMG signal is of great importance in the dexterous control of the EMG prosthetic hand. In this paper, an action force estimation method which is based on the eight channels of the surface EMG (sEMG and the Generalized Regression Neural Network (GRNN is proposed to meet the requirements of the force control of the intelligent EMG prosthetic hand. Firstly, the experimental platform, the acquisition of the sEMG, the feature extraction of the sEMG and the construction of GRNN are described. Then, the multi-channels of the sEMG when the hand is moving are captured by the EMG sensors attached on eight different positions of the arm skin surface. Meanwhile, a grip force sensor and a three dimension force sensor are adopted to measure the output force of the human's hand. The characteristic matrix of the sEMG and the force signals are used to construct the GRNN. The mean absolute value and the root mean square of the estimation errors, the correlation coefficients between the actual force and the estimated force are employed to assess the accuracy of the estimation. Analysis of variance (ANOVA is also employed to test the difference of the force estimation. The experiments are implemented to verify the effectiveness of the proposed estimation method and the results show that the output force of the human's hand can be correctly estimated by using sEMG and GRNN method.

  4. The bilateral movement condition facilitates maximal but not submaximal paretic-limb grip force in people with post-stroke hemiparesis

    Science.gov (United States)

    DeJong, Stacey L.; Lang, Catherine E.

    2012-01-01

    Objectives Although healthy individuals have less force production capacity during bilateral muscle contractions compared to unilateral efforts, emerging evidence suggests that certain aspects of paretic upper limb task performance after stroke may be enhanced by moving bilaterally instead of unilaterally. We investigated whether the bilateral movement condition affects grip force differently on the paretic side of people with post-stroke hemiparesis, compared to their non-paretic side and both sides of healthy young adults. Methods Within a single session, we compared: 1) maximal grip force during unilateral vs. bilateral contractions on each side, and 2) force contributed by each side during a 30% submaximal bilateral contraction. Results Healthy controls produced less grip force in the bilateral condition, regardless of side (- 2.4% difference), and similar findings were observed on the non-paretic side of people with hemiparesis (- 4.5% difference). On the paretic side, however, maximal grip force was increased by the bilateral condition in most participants (+11.3% difference, on average). During submaximal bilateral contractions in each group, the two sides each contributed the same percentage of unilateral maximal force. Conclusions The bilateral condition facilitates paretic limb grip force at maximal, but not submaximal levels. Significance In some people with post-stroke hemiparesis, the paretic limb may benefit from bilateral training with high force requirements. PMID:22248812

  5. Influences of load characteristics on impaired control of grip forces in patients with cerebellar damage.

    Science.gov (United States)

    Brandauer, B; Timmann, D; Häusler, A; Hermsdörfer, J

    2010-02-01

    Various studies showed a clear impairment of cerebellar patients to modulate grip force in anticipation of the loads resulting from movements with a grasped object. This failure corroborated the theory of internal feedforward models in the cerebellum. Cerebellar damage also impairs the coordination of multiple-joint movements and this has been related to deficient prediction and compensation of movement-induced torques. To study the effects of disturbed torque control on feedforward grip-force control, two self-generated load conditions with different demands on torque control-one with movement-induced and the other with isometrically generated load changes-were directly compared in patients with cerebellar degeneration. Furthermore the cerebellum is thought to be more involved in grip-force adjustment to self-generated loads than to externally generated loads. Consequently, an additional condition with externally generated loads was introduced to further test this hypothesis. Analysis of 23 patients with degenerative cerebellar damage revealed clear impairments in predictive feedforward mechanisms in the control of both self-generated load types. Besides feedforward control, the cerebellar damage also affected more reactive responses when the externally generated load destabilized the grip, although this impairment may vary with the type of load as suggested by control experiments. The present findings provide further support that the cerebellum plays a major role in predictive control mechanisms. However, this impact of the cerebellum does not strongly depend on the nature of the load and the specific internal forward model. Contributions to reactive (grip force) control are not negligible, but seem to be dependent on the physical characteristics of an externally generated load.

  6. Development of force sensing circuit to determine the optimal force required for effective dynamic tripod grip/writing

    Science.gov (United States)

    Suraj S., S.; Kulkarni, Palash; Bokadia, Pratik; Ramanathan, Prabhu; Nageswaran, Sharmila

    2018-04-01

    Handwriting is a combination of fine motor perceptions and cognitive skills to produce words on paper. For writing, the most commonly used and recommended grip is the dynamic tripod grip. A child's handwriting starts developing during the times of pre-schooling and improves over time. While writing, children apply excessive force on the writing instrument. This force is exerted by their fingers and as per the law of reaction, the writing instruments tend to exert an equal and opposite force, that could damage the delicate soft tissue structures in their fingers and initiate cramps and pains. This condition is also prevalent in adults who tend to write for long hours under pressure. An example would be adolescence student during the exams. Clinically this condition is termed as `Writer's Cramp', which is usually characterized by muscle fatigue and pain in the fingers. By understanding and fixing the threshold of the force that should be exerted by the fingers while gripping the instrument, the pain can be controlled or avoided. This research aims in designing an electronic module which can help in understanding the threshold of pressure which is optimum enough to establish a better contact between the fingers and the instrument and should be capable of controlling or avoiding the pain. The design of FSR based electronic system is explained with its circuitry and results of initial testing is presented in this paper.

  7. Applying support vector regression analysis on grip force level-related corticomuscular coherence

    DEFF Research Database (Denmark)

    Rong, Yao; Han, Xixuan; Hao, Dongmei

    2014-01-01

    Voluntary motor performance is the result of cortical commands driving muscle actions. Corticomuscular coherence can be used to examine the functional coupling or communication between human brain and muscles. To investigate the effects of grip force level on corticomuscular coherence in an acces...

  8. Real time relationship between individual finger force and grip exertion on distal phalanges in linear force following tasks.

    Science.gov (United States)

    Luo, Shi-Jian; Shu, Ge; Gong, Yan

    2018-05-01

    Individual finger force (FF) in a grip task is a vital concern in rehabilitation engineering and precise control of manipulators because disorders in any of the fingers will affect the stability or accuracy of the grip force (GF). To understand the functions of each finger in a dynamic grip exertion task, a GF following experiment with four individual fingers without thumb was designed. This study obtained four individual FFs from the distal phalanges with a cylindrical handle in dynamic GF following tasks. Ten healthy male subjects with similar hand sizes participated in the four-finger linear GF following tasks at different submaximal voluntary contraction (SMVC) levels. The total GF, individual FF, finger force contribution, and following error were subsequently calculated and analyzed. The statistics indicated the following: 1) the accuracy and stability of GF at low %MVC were significantly higher than those at high SMVC; 2) at low SMVC, the ability of the fingers to increase the GF was better than the ability to reduce it, but it was contrary at high SMVC; 3) when the target wave (TW) was changing, all four fingers strongly participated in the force exertion, but the participation of the little finger decreased significantly when TW remained stable; 4) the index finger and ring finger had a complementary relationship and played a vital role in the adjustment and control of GF. The middle finger and little finger had a minor influence on the force control and adjustment. In conclusion, each of the fingers had different functions in a GF following task. These findings can be used in the assessment of finger injury rehabilitation and for algorithms of precise control. Copyright © 2017 Elsevier Ltd. All rights reserved.

  9. Key Insights into Hand Biomechanics: Human Grip Stiffness Can Be Decoupled from Force by Cocontraction and Predicted from Electromyography

    Directory of Open Access Journals (Sweden)

    Hannes Höppner

    2017-05-01

    Full Text Available We investigate the relation between grip force and grip stiffness for the human hand with and without voluntary cocontraction. Apart from gaining biomechanical insight, this issue is particularly relevant for variable-stiffness robotic systems, which can independently control the two parameters, but for which no clear methods exist to design or efficiently exploit them. Subjects were asked in one task to produce different levels of force, and stiffness was measured. As expected, this task reveals a linear coupling between force and stiffness. In a second task, subjects were then asked to additionally decouple stiffness from force at these force levels by using cocontraction. We measured the electromyogram from relevant groups of muscles and analyzed the possibility to predict stiffness and force. Optical tracking was used for avoiding wrist movements. We found that subjects were able to decouple grip stiffness from force when using cocontraction on average by about 20% of the maximum measured stiffness over all force levels, while this ability increased with the applied force. This result contradicts the force–stiffness behavior of most variable-stiffness actuators. Moreover, we found the thumb to be on average twice as stiff as the index finger and discovered that intrinsic hand muscles predominate our prediction of stiffness, but not of force. EMG activity and grip force allowed to explain 72 ± 12% of the measured variance in stiffness by simple linear regression, while only 33 ± 18% variance in force. Conclusively the high signal-to-noise ratio and the high correlation to stiffness of these muscles allow for a robust and reliable regression of stiffness, which can be used to continuously teleoperate compliance of modern robotic hands.

  10. Variability of grip kinetics during adult signature writing.

    Directory of Open Access Journals (Sweden)

    Bassma Ghali

    Full Text Available Grip kinetics and their variation are emerging as important considerations in the clinical assessment of handwriting pathologies, fine motor rehabilitation, biometrics, forensics and ergonomic pen design. This study evaluated the intra- and inter-participant variability of grip shape kinetics in adults during signature writing. Twenty (20 adult participants wrote on a digitizing tablet using an instrumented pen that measured the forces exerted on its barrel. Signature samples were collected over 10 days, 3 times a day, to capture temporal variations in grip shape kinetics. A kinetic topography (i.e., grip shape image was derived per signature by time-averaging the measured force at each of 32 locations around the pen barrel. The normalized cross correlations (NCC of grip shape images were calculated within- and between-participants. Several classification algorithms were implemented to gauge the error rate of participant discrimination based on grip shape kinetics. Four different grip shapes emerged and several participants made grip adjustments (change in grip shape or grip height or rotated the pen during writing. Nonetheless, intra-participant variation in grip kinetics was generally much smaller than inter-participant force variations. Using the entire grip shape images as a 32-dimensional input feature vector, a K-nearest neighbor classifier achieved an error rate of 1.2±0.4% in discriminating among participants. These results indicate that writers had unique grip shape kinetics that were repeatable over time but distinct from those of other participants. The topographic analysis of grip kinetics may inform the development of personalized interventions or customizable grips in clinical and industrial applications, respectively.

  11. Relationships between Mechanical Variables in the Traditional and Close-Grip Bench Press.

    Science.gov (United States)

    Lockie, Robert G; Callaghan, Samuel J; Moreno, Matthew R; Risso, Fabrice G; Liu, Tricia M; Stage, Alyssa A; Birmingham-Babauta, Samantha A; Stokes, John J; Giuliano, Dominic V; Lazar, Adrina; Davis, DeShaun L; Orjalo, Ashley J

    2017-12-01

    The study aim was to determine relationships between mechanical variables in the one-repetition maximum (1RM) traditional bench press (TBP) and close-grip bench press (CGBP). Twenty resistance-trained men completed a TBP and CGBP 1RM. The TBP was performed with the preferred grip; the CGBP with a grip width of 95% biacromial distance. A linear position transducer measured: lift distance and duration; work; and peak and mean power, velocity, and force. Paired samples t-tests (p velocity was greater for the CGBP (d = 0.50-1.29). The 1RM TBP correlated with CGBP 1RM, power, and force (r = 0.685-0.982). TBP work correlated with CGBP 1RM, lift distance, power, force, and work (r = 0.542-0.931). TBP power correlated with CGBP 1RM, power, force, velocity, and work (r = 0.484-0.704). TBP peak and mean force related to CGBP 1RM, power, and force (r = 0.596-0.980). Due to relationships between the load, work, power, and force for the TBP and CGBP, the CGBP could provide similar strength adaptations to the TBP with long-term use. The velocity profile for the CGBP was different to that of the TBP. The CGBP could be used specifically to improve high-velocity, upper-body pushing movements.

  12. Control of finger forces during fast, slow and moderate rotational hand movements.

    Science.gov (United States)

    Kazemi, Hamed; Kearney, Robert E; Milner, Theodore E

    2014-01-01

    The goal of this study was to investigate the effect of speed on patterns of grip forces during twisting movement involving forearm supination against a torsional load (combined elastic and inertial load). For slow and moderate speed rotations, the grip force increased linearly with load torque. However, for fast rotations in which the contribution of the inertia to load torque was significantly greater than slower movements, the grip force-load torque relationship could be segmented into two phases: a linear ascending phase corresponding to the acceleration part of the movement followed by a plateau during deceleration. That is, during the acceleration phase, the grip force accurately tracked the combined elastic and inertial load. However, the coupling between grip force and load torque was not consistent during the deceleration phase of the movement. In addition, as speed increased, both the position and the force profiles became smoother. No differences in the baseline grip force, safety margin to secure the grasp during hold phase or the overall change in grip force were observed across different speeds.

  13. The brain adjusts grip forces differently according to gravity and inertia: a parabolic flight experiment

    Science.gov (United States)

    White, Olivier

    2015-01-01

    In everyday life, one of the most frequent activities involves accelerating and decelerating an object held in precision grip. In many contexts, humans scale and synchronize their grip force (GF), normal to the finger/object contact, in anticipation of the expected tangential load force (LF), resulting from the combination of the gravitational and the inertial forces. In many contexts, GF and LF are linearly coupled. A few studies have examined how we adjust the parameters–gain and offset–of this linear relationship. However, the question remains open as to how the brain adjusts GF regardless of whether LF is generated by different combinations of weight and inertia. Here, we designed conditions to generate equivalent magnitudes of LF by independently varying mass and movement frequency. In a control experiment, we directly manipulated gravity in parabolic flights, while other factors remained constant. We show with a simple computational approach that, to adjust GF, the brain is sensitive to how LFs are produced at the fingertips. This provides clear evidence that the analysis of the origin of LF is performed centrally, and not only at the periphery. PMID:25717293

  14. Bilateral deficits in fine motor control and pinch grip force are not associated with electrodiagnostic findings in women with carpal tunnel syndrome.

    Science.gov (United States)

    de la Llave-Rincón, Ana Isabel; Fernández-de-Las-Peñas, César; Pérez-de-Heredia-Torres, Marta; Martínez-Perez, Almudena; Valenza, Marie Carmen; Pareja, Juan A

    2011-06-01

    : The aim of this study was to analyze the differences in deficits in fine motor control and pinch grip force between patients with minimal, moderate/mild, or severe carpal tunnel syndrome (CTS) and healthy age- and hand dominance-matched controls. : A case-control study was conducted. The subtests of the Purdue Pegboard Test (one-hand and bilateral pin placements and assemblies) and pinch grip force between the thumb and the remaining four fingers of the hand were bilaterally evaluated in 66 women with minimal (n = 16), moderate (n = 16), or severe (n = 34) CTS and in 20 age- and hand-matched healthy women. The differences among the groups were analyzed using different mixed models of analysis of variance. : A two-way mixed analysis of variance revealed significant differences between groups, not depending on the presence of unilateral or bilateral symptoms (side), for the one-hand pin placement subtest: patients showed bilateral lower scores compared with controls (P < 0.001), without differences among those with minimal, moderate, or severe CTS (P = 0.946). The patients also exhibited lower scores in bilateral pin placement (P < 0.001) and assembly (P < 0.001) subtests, without differences among them. The three-way analysis of variance revealed significant differences among groups (P < 0.001) and fingers (P < 0.001), not depending on the presence of unilateral/bilateral symptoms (P = 0.684), for pinch grip force: patients showed bilateral lower pinch grip force in all fingers compared with healthy controls, without differences among those with minimal, moderate, or severe CTS. : The current study revealed similar bilateral deficits in fine motor control and pinch grip force in patients with minimal, moderate, or severe CTS, supporting that fine motor control deficits are a common feature of CTS not associated with electrodiagnostic findings.

  15. Relationships between Mechanical Variables in the Traditional and Close-Grip Bench Press

    Directory of Open Access Journals (Sweden)

    Lockie Robert G.

    2017-12-01

    Full Text Available The study aim was to determine relationships between mechanical variables in the one-repetition maximum (1RM traditional bench press (TBP and close-grip bench press (CGBP. Twenty resistance-trained men completed a TBP and CGBP 1RM. The TBP was performed with the preferred grip; the CGBP with a grip width of 95% biacromial distance. A linear position transducer measured: lift distance and duration; work; and peak and mean power, velocity, and force. Paired samples t-tests (p < 0.05 compared the 1RM and mechanical variables for the TBP and CGBP; effect sizes (d were also calculated. Pearson’s correlations (r; p < 0.05 computed relationships between the TBP and CGBP. 1RM, lift duration, and mean force were greater in the TBP (d = 0.30-3.20. Peak power and velocity was greater for the CGBP (d = 0.50-1.29. The 1RM TBP correlated with CGBP 1RM, power, and force (r = 0.685-0.982. TBP work correlated with CGBP 1RM, lift distance, power, force, and work (r = 0.542-0.931. TBP power correlated with CGBP 1RM, power, force, velocity, and work (r = 0.484-0.704. TBP peak and mean force related to CGBP 1RM, power, and force (r = 0.596-0.980. Due to relationships between the load, work, power, and force for the TBP and CGBP, the CGBP could provide similar strength adaptations to the TBP with long-term use. The velocity profile for the CGBP was different to that of the TBP. The CGBP could be used specifically to improve high-velocity, upper-body pushing movements.

  16. Study on the collision-mechanical properties of tomatoes gripped by ...

    African Journals Online (AJOL)

    The data of collision-mechanical property of tomatoes gripped by robot fingers are important for the gripping control of tomato harvesting robot. In the study, tests of controlling the fingers to grip tomatoes were conducted to ascertain the effects of input current, motor speed and impact positions on the impact force of fingers ...

  17. Performance of repetitive tasks induces decreased grip strength and increased fibrogenic proteins in skeletal muscle: role of force and inflammation.

    Directory of Open Access Journals (Sweden)

    Samir M Abdelmagid

    Full Text Available This study elucidates exposure-response relationships between performance of repetitive tasks, grip strength declines, and fibrogenic-related protein changes in muscles, and their link to inflammation. Specifically, we examined forearm flexor digitorum muscles for changes in connective tissue growth factor (CTGF; a matrix protein associated with fibrosis, collagen type I (Col1; a matrix component, and transforming growth factor beta 1 (TGFB1; an upstream modulator of CTGF and collagen, in rats performing one of two repetitive tasks, with or without anti-inflammatory drugs.To examine the roles of force versus repetition, rats performed either a high repetition negligible force food retrieval task (HRNF, or a high repetition high force handle-pulling task (HRHF, for up to 9 weeks, with results compared to trained only (TR-NF or TR-HF and normal control rats. Grip strength declined with both tasks, with the greatest declines in 9-week HRHF rats. Quantitative PCR (qPCR analyses of HRNF muscles showed increased expression of Col1 in weeks 3-9, and CTGF in weeks 6 and 9. Immunohistochemistry confirmed PCR results, and also showed greater increases of CTGF and collagen matrix in 9-week HRHF rats than 9-week HRNF rats. ELISA, and immunohistochemistry revealed greater increases of TGFB1 in TR-HF and 6-week HRHF, compared to 6-week HRNF rats. To examine the role of inflammation, results from 6-week HRHF rats were compared to rats receiving ibuprofen or anti-TNF-α treatment in HRHF weeks 4-6. Both treatments attenuated HRHF-induced increases in CTGF and fibrosis by 6 weeks of task performance. Ibuprofen attenuated TGFB1 increases and grip strength declines, matching our prior results with anti-TNFα.Performance of highly repetitive tasks was associated with force-dependent declines in grip strength and increased fibrogenic-related proteins in flexor digitorum muscles. These changes were attenuated, at least short-term, by anti-inflammatory treatments.

  18. Systems and Methods for Gravity-Independent Gripping and Drilling

    Science.gov (United States)

    Parness, Aaron (Inventor); Frost, Matthew A. (Inventor); Thatte, Nitish (Inventor); King, Jonathan P. (Inventor)

    2016-01-01

    Systems and methods for gravity independent gripping and drilling are described. The gripping device can also comprise a drill or sampling devices for drilling and/or sampling in microgravity environments, or on vertical or inverted surfaces in environments where gravity is present. A robotic system can be connected with the gripping and drilling devices via an ankle interface adapted to distribute the forces realized from the robotic system.

  19. Weight-specific anticipatory coding of grip force in human dorsal premotor cortex

    DEFF Research Database (Denmark)

    van Nuenen, Bart F L; Kuhtz-Buschbeck, Johann; Schulz, Christian

    2012-01-01

    , using either continuous theta burst stimulation (cTBS) at 80% (inhibitory cTBS) or 30% (sham cTBS) of active motor threshold. The conditioning effects of cTBS on preparatory brain activity were assessed with functional MRI, while participants lifted a light or heavy weight in response to a go-cue (S2......). An additional pre-cue (S1) correctly predicted the weight in 75% of the trials. Participants were asked to use this prior information to prepare for the lift. In the sham condition, grip force showed a consistent undershoot, if the S1 incorrectly prompted the preparation of a light lift. Likewise, an S1...... during object lifting....

  20. The role of left supplementary motor area in grip force scaling.

    Directory of Open Access Journals (Sweden)

    Olivier White

    Full Text Available Skilled tool use and object manipulation critically relies on the ability to scale anticipatorily the grip force (GF in relation to object dynamics. This predictive behaviour entails that the nervous system is able to store, and then select, the appropriate internal representation of common object dynamics, allowing GF to be applied in parallel with the arm motor commands. Although psychophysical studies have provided strong evidence supporting the existence of internal representations of object dynamics, known as "internal models", their neural correlates are still debated. Because functional neuroimaging studies have repeatedly designated the supplementary motor area (SMA as a possible candidate involved in internal model implementation, we used repetitive transcranial magnetic stimulation (rTMS to interfere with the normal functioning of left or right SMA in healthy participants performing a grip-lift task with either hand. TMS applied over the left, but not right, SMA yielded an increase in both GF and GF rate, irrespective of the hand used to perform the task, and only when TMS was delivered 130-180 ms before the fingers contacted the object. We also found that both left and right SMA rTMS led to a decrease in preload phase durations for contralateral hand movements. The present study suggests that left SMA is a crucial node in the network processing the internal representation of object dynamics although further experiments are required to rule out that TMS does not affect the GF gain. The present finding also further substantiates the left hemisphere dominance in scaling GF.

  1. The effects of grip width on sticking region in bench press.

    Science.gov (United States)

    Gomo, Olav; Van Den Tillaar, Roland

    2016-01-01

    The aim of this study was to examine the occurrence of the sticking region by examining how three different grip widths affect the sticking region in powerlifters' bench press performance. It was hypothesised that the sticking region would occur at the same joint angle of the elbow and shoulder independent of grip width, indicating a poor mechanical region for vertical force production at these joint angles. Twelve male experienced powerlifters (age 27.7 ± 8.8 years, mass 91.9 ± 15.4 kg) were tested in one repetition maximum (1-RM) bench press with a narrow, medium and wide grip. Joint kinematics, timing, bar position and velocity were measured with a 3D motion capture system. All participants showed a clear sticking region with all three grip widths, but this sticking region was not found to occur at the same joint angles in all three grip widths, thereby rejecting the hypothesis that the sticking region would occur at the same joint angle of the elbow and shoulder independent of grip width. It is suggested that, due to the differences in moment arm of the barbell about the elbow joint in the sticking region, there still might be a poor mechanical region for total force production that is joint angle-specific.

  2. Reference Values of Grip Strength, Prevalence of Low Grip Strength, and Factors Affecting Grip Strength Values in Chinese Adults.

    Science.gov (United States)

    Yu, Ruby; Ong, Sherlin; Cheung, Osbert; Leung, Jason; Woo, Jean

    2017-06-01

    The objectives of this study were to update the reference values of grip strength, to estimate the prevalence of low grip strength, and to examine the impact of different aspects of measurement protocol on grip strength values in Chinese adults. A cross-sectional survey of Chinese men (n = 714) and women (n = 4014) aged 18-102 years was undertaken in different community settings in Hong Kong. Grip strength was measured with a digital dynamometer (TKK 5401 Grip-D; Takei, Niigata, Japan). Low grip strength was defined as grip strength 2 standard deviations or more below the mean for young adults. The effects of measurement protocol on grip strength values were examined in a subsample of 45 men and women with repeated measures of grip strength taken with a hydraulic dynamometer (Baseline; Fabrication Enterprises Inc, Irvington, NY), using pair t-tests, intraclass correlation coefficient, and Bland and Altman plots. Grip strength was greater among men than among women (P values than the Baseline hydraulic dynamometer (P values were also observed when the measurement was performed with the elbow extended in a standing position, compared with that with the elbow flexed at 90° in a sitting position, using the same dynamometer (P values of grip strength and estimated the prevalence of low grip strength among Chinese adults spanning a wide age range. These findings might be useful for risk estimation and evaluation of interventions. However, grip strength measurements should be interpreted with caution, as grip strength values can be affected by type of dynamometer used, assessment posture, and elbow position. Copyright © 2017 AMDA – The Society for Post-Acute and Long-Term Care Medicine. Published by Elsevier Inc. All rights reserved.

  3. Altered visual strategies and attention are related to increased force fluctuations during a pinch grip task in older adults.

    Science.gov (United States)

    Keenan, Kevin G; Huddleston, Wendy E; Ernest, Bradley E

    2017-11-01

    The purpose of the study was to determine the visual strategies used by older adults during a pinch grip task and to assess the relations between visual strategy, deficits in attention, and increased force fluctuations in older adults. Eye movements of 23 older adults (>65 yr) were monitored during a low-force pinch grip task while subjects viewed three common visual feedback displays. Performance on the Grooved Pegboard test and an attention task (which required no concurrent hand movements) was also measured. Visual strategies varied across subjects and depended on the type of visual feedback provided to the subjects. First, while viewing a high-gain compensatory feedback display (horizontal bar moving up and down with force), 9 of 23 older subjects adopted a strategy of performing saccades during the task, which resulted in 2.5 times greater force fluctuations in those that exhibited saccades compared with those who maintained fixation near the target line. Second, during pursuit feedback displays (force trace moving left to right across screen and up and down with force), all subjects exhibited multiple saccades, and increased force fluctuations were associated ( r s = 0.6; P = 0.002) with fewer saccades during the pursuit task. Also, decreased low-frequency (attention z scores. Comparison of these results with our previously published results in young subjects indicates that saccadic eye movements and attention are related to force control in older adults. NEW & NOTEWORTHY The significant contributions of the study are the addition of eye movement data and an attention task to explain differences in hand motor control across different visual displays in older adults. Older participants used different visual strategies across varying feedback displays, and saccadic eye movements were related with motor performance. In addition, those older individuals with deficits in attention had impaired motor performance on two different hand motor control tasks, including

  4. Effects of Anodal Transcranial Direct Current Stimulation on Visually Guided Learning of Grip Force Control

    Directory of Open Access Journals (Sweden)

    Tamas Minarik

    2015-03-01

    Full Text Available Anodal transcranial Direct Current Stimulation (tDCS has been shown to be an effective non-invasive brain stimulation method for improving cognitive and motor functioning in patients with neurological deficits. tDCS over motor cortex (M1, for instance, facilitates motor learning in stroke patients. However, the literature on anodal tDCS effects on motor learning in healthy participants is inconclusive, and the effects of tDCS on visuo-motor integration are not well understood. In the present study we examined whether tDCS over the contralateral motor cortex enhances learning of grip-force output in a visually guided feedback task in young and neurologically healthy volunteers. Twenty minutes of 1 mA anodal tDCS were applied over the primary motor cortex (M1 contralateral to the dominant (right hand, during the first half of a 40 min power-grip task. This task required the control of a visual signal by modulating the strength of the power-grip for six seconds per trial. Each participant completed a two-session sham-controlled crossover protocol. The stimulation conditions were counterbalanced across participants and the sessions were one week apart. Performance measures comprised time-on-target and target-deviation, and were calculated for the periods of stimulation (or sham and during the afterphase respectively. Statistical analyses revealed significant performance improvements over the stimulation and the afterphase, but this learning effect was not modulated by tDCS condition. This suggests that the form of visuomotor learning taking place in the present task was not sensitive to neurostimulation. These null effects, together with similar reports for other types of motor tasks, lead to the proposition that tDCS facilitation of motor learning might be restricted to cases or situations where the motor system is challenged, such as motor deficits, advanced age, or very high task demand.

  5. White matter organization in cervical spinal cord relates differently to age and control of grip force in healthy subjects.

    Science.gov (United States)

    Lindberg, Påvel G; Feydy, Antoine; Maier, Marc A

    2010-03-17

    Diffusion tensor imaging (DTI) can be used to elucidate relations between CNS structure and function. We hypothesized that the degree of spinal white matter organization relates to the accuracy of control of grip force. Healthy subjects of different age were studied using DTI and visuomotor tracking of precision grip force. The latter is a prime component of manual dexterity. A regional analysis of spinal white matter [fractional anisotropy (FA)] across multiple cervical levels (C2-C3, C4-C5, and C6-C7) and in different regions of interest (left and right lateral or medial spinal cord) was performed. FA was highest at the C2-C3 level, higher on the right than the left side, and higher in the lateral than in the medial spinal cord (p level in the lateral spinal cord, in which the corticospinal tract innervates spinal circuitry controlling hand and digit muscles. FA of the medial spinal cord correlated consistently with age across all cervical levels, whereas FA of the lateral spinal cord did not. The results suggest (1) a functionally relevant specialization of lateral spinal cord white matter and (2) an increased sensitivity to age-related decline in medial spinal cord white matter in healthy subjects.

  6. Effects of glovebox gloves on grip and key pinch strength and contact forces for simulated manual operations with three commonly used hand tools.

    Science.gov (United States)

    Sung, Peng-Cheng

    2014-01-01

    This study examined the effects of glovebox gloves for 11 females on maximum grip and key pinch strength and on contact forces generated from simulated tasks of a roller, a pair of tweezers and a crescent wrench. The independent variables were gloves fabricated of butyl, CSM/hypalon and neoprene materials; two glove thicknesses; and layers of gloves worn including single, double and triple gloving. CSM/hypalon and butyl gloves produced greater grip strength than the neoprene gloves. CSM/hypalon gloves also lowered contact forces for roller and wrench tasks. Single gloving and thin gloves improved hand strength performances. However, triple layers lowered contact forces for all tasks. Based on the evaluating results, selection and design recommendations of gloves for three hand tools were provided to minimise the effects on hand strength and optimise protection of the palmar hand in glovebox environments. To improve safety and health in the glovebox environments where gloves usage is a necessity, this study provides recommendations for selection and design of glovebox gloves for three hand tools including a roller, a pair of tweezers and a crescent wrench based on the results discovered in the experiments.

  7. Relationship between lung function and grip strength in older hospitalized patients: a pilot study

    Directory of Open Access Journals (Sweden)

    Holmes SJ

    2017-04-01

    Full Text Available Sarah J Holmes,1 Stephen C Allen,2,3 Helen C Roberts4,5 1Medicine and Elderly Care, Hampshire Hospitals NHS Foundation Trust, Winchester, 2Medicine and Geriatrics, The Royal Bournemouth Hospital and Christchurch Hospitals NHS Foundation Trust, Bournemouth, 3Centre of Postgraduate Medical Research and Education, Bournemouth University, Poole, 4Academic Geriatric Medicine, University of Southampton, 5University Hospital Southampton NHS Foundation Trust, Southampton, UK Objective: Older people with reduced respiratory muscle strength may be misclassified as having COPD on the basis of spirometric results. We aimed to evaluate the relationship between lung function and grip strength in older hospitalized patients without known airways disease.Methods: Patients in acute medical wards were recruited who were aged ≥70 years; no history, symptoms, or signs of respiratory disease; Mini Mental State Examination ≥24; willing and able to consent to participate; and able to perform hand grip and forced spirometry. Data including lung function (forced expiratory volume in 1 second [FEV1], forced vital capacity [FVC], FEV1/FVC, peak expiratory flow rate [PEFR], and slow vital capacity [SVC], grip strength, age, weight, and height were recorded. Data were analyzed using descriptive statistics and linear regression unadjusted and adjusted (for age, height, and weight.Results: A total of 50 patients (20 men were recruited. Stronger grip strength in men was significantly associated with greater FEV1, but this was attenuated by adjustment for age, height, and weight. Significant positive associations were found in women between grip strength and both PEFR and SVC, both of which remained robust to adjustment.Conclusion: The association between grip strength and PEFR and SVC may reflect stronger patients generating higher intrathoracic pressure at the start of spirometry and pushing harder against thoracic cage recoil at end-expiration. Conversely, patients with

  8. Hand Grip Strength Vs. Sprint Effectiveness in Amputee Soccer Players.

    Science.gov (United States)

    Wieczorek, Marta; Wiliński, Wojciech; Struzik, Artur; Rokita, Andrzej

    2015-11-22

    Amputee soccer is one of the types of soccer designed for the disabled, especially those who have undergone amputations, as well as those with extremity dysfunction. The objective of the study was to find the relationship between hand grip strength and sprint time in amputee soccer players. Thirteen field amputee soccer players participated in the study. A SAEHAN hydraulic hand dynamometer manufactured by Jamar was used for hand grip strength measurements. The sprint running test was conducted over a distance of 30 m. The Fusion Smart Speed System was employed for running time measurements. No statistically significant relationships were found between hand grip strength of the left or right hand, and sprint times over 1, 5, 10, 15, 20, 25 and 30 m. Analysis of the running velocity curve of the subjects showed an interesting profile characterized by a 15 meter-long acceleration phase and a significant velocity increase over a distance of 20 - 25 m. The study suggests that there is no relationship between hand grip strength and sprint effectiveness in amputee soccer players. The specificity of locomotion with the use of elbow crutches among elite Polish amputee soccer players probably accounts for the profile of the sprint velocity curve. Extension of the acceleration phase in the sprint run and a velocity increase in the subsequent part of the run were observed.

  9. Hand Grip Strength Vs. Sprint Effectiveness in Amputee Soccer Players

    Directory of Open Access Journals (Sweden)

    Wieczorek Marta

    2015-12-01

    Full Text Available Amputee soccer is one of the types of soccer designed for the disabled, especially those who have undergone amputations, as well as those with extremity dysfunction. The objective of the study was to find the relationship between hand grip strength and sprint time in amputee soccer players. Thirteen field amputee soccer players participated in the study. A SAEHAN hydraulic hand dynamometer manufactured by Jamar was used for hand grip strength measurements. The sprint running test was conducted over a distance of 30 m. The Fusion Smart Speed System was employed for running time measurements. No statistically significant relationships were found between hand grip strength of the left or right hand, and sprint times over 1, 5, 10, 15, 20, 25 and 30 m. Analysis of the running velocity curve of the subjects showed an interesting profile characterized by a 15 meter-long acceleration phase and a significant velocity increase over a distance of 20 – 25 m. The study suggests that there is no relationship between hand grip strength and sprint effectiveness in amputee soccer players. The specificity of locomotion with the use of elbow crutches among elite Polish amputee soccer players probably accounts for the profile of the sprint velocity curve. Extension of the acceleration phase in the sprint run and a velocity increase in the subsequent part of the run were observed.

  10. ANALYSIS OF POWER GRIP AND PINCH GRIP AMONG HEALTH CARE PROFESSIONALS

    Directory of Open Access Journals (Sweden)

    Zakariya M P

    2016-02-01

    Full Text Available Background: Grip and pinch strength are commonly employed indices of strength used in hand evaluations. Pinch grip and power grip strengths are used as indices of strength in hand therapy assessments. For all professions grip strength is an important criterion to be successful in their profession. Such phenomena may be explained by differences in nature of work, working environment, and objects workers handle. Method: 200 healthy subjects, satisfying the selection criteria were included and assessed with standardized procedure for power grip and pinch grip (lateral pinch, pad-pad, and tip-tip strength. They were divided in four groups, 50 group each according to profession i.e. medical surgeons, dentist, physiotherapists and nurses. Results: The mean power grip strength shows highly significant difference between medical vs. dental (p>0.01 and medical vs. physiotherapy group (p> 0.05 .The mean lateral pinch strength shows there is highly significant difference (p< 0.001 between dental vs. nursing profession and dental vs. physiotherapy group. No significant difference among other groups. The mean pad-pad pinch strength shows there is significant difference between dental vs. nursing (p< 0.05 and dental vs physiotherapy group (p< 0.05. The mean Tip-Tip pinch strength shows there is significant difference between dental vs nursing profession(p< 0.05 and dental vs. physiotherapy(p< 0.05. No significant different among other groups. Conclusion: Surgeons have highest power grip strength followed by Nursing, Physiotherapy and Dental professionals. Dentists have the maximum pinch strength in all three positions, followed by Surgeons, Nurses and Physiotherapists. Surgeons have maximum pinch strength next to Dentists.

  11. Mind Your Grip: Even Usual Dexterous Manipulation Requires High Level Cognition

    Directory of Open Access Journals (Sweden)

    Erwan Guillery

    2017-11-01

    Full Text Available Simultaneous execution of cognitive and sensorimotor tasks is critical in daily life. Here, we examined whether dexterous manipulation, a highly habitual and seemingly automatic behavior, involves high order cognitive functions. Specifically, we explored the impact of reducing available cognitive resources on the performance of a precision grip-lift task in healthy participants of three age groups (18–30, 30–60 and 60–75 years. Participants performed a motor task in isolation (M, in combination with a low-load cognitive task (M + L, and in combination with a high-load cognitive task (M + H. The motor task consisted in grasping, lifting and holding an apparatus instrumented with force sensors to monitor motor task performance. In the cognitive task, a list of letters was shown briefly before the motor task. After completing the motor task, one letter of the list was shown, and participants reported the following letter of the list. In M + L, letters in the list followed the alphabetical order. In M + H, letters were presented in random order. Performing the high-load task thus required maintaining information in working memory. Temporal and dynamic parameters of grip and lift forces were compared across conditions. During the cognitive tasks, there was a significant alteration of movement initiation and a significant increase of grip force (GF throughout the grip-lift task. There was no interaction with “age”. Our results demonstrate that planning and the on-line control of dexterous manipulation is not an automatic behavior and, instead, that it interacts with high-level cognitive processes such as those involved in working memory.

  12. Functional relationship between dominant and non-dominant hand in motor task - hand grip strength endurance

    Directory of Open Access Journals (Sweden)

    Kljajić Dragana

    2012-01-01

    Full Text Available The aim of this study was to determine the functional relationship between dominant and non-dominant hand in the strength endurance motor task - hand grip, in the referent population of healthy and young persons. For the purpose of the research we have implemented the method of isometric dynamometry and standardized hand grip test. The study included 48 participants, 23 of them being of female and 25 of male gender. The analysis of variance (ANOVA was used to determine the difference between the sets of variables in the function of gender and functional dimorphism, while the Bonferroni criterion was applied to determine the differences between pairs of individual variables. The difference between the maximum hand grip of dominant and non-dominant hand in female participants amounted to 9.28%, and in male ones 7.39% in favor of the dominant hand. There is no statistically significant difference between nondominant and dominant hand regarding the force endurance time aspect at 30%, 50% and 80% out of the maximum hand grip level, as well as at the absolute and relative force impulse indicators as an endurance measure. The value of gender dimorphism in relation to the absolute indicators of force momentum at 30%, 50% and 80% out of the maximum hand grip level in female participants is 0.9714, 0.9145, 0.9301, and in male participants 0.9515, 0.8264 and 0.8606. The force momentum indicators value at 30%, 50% and 80% out of the maximum hand grip level in female participants is ImpF30%=21167.58±6923.67 Ns, ImpF50%=10846.94±3800.56 Ns and ImpF80%=5438.46±1993.12 Ns, and in male participants ImpF30%=17734.03±6881.92 Ns, ImpF50%=13903.61±3437.76 Ns and ImpF80%=5117.53±1894.78 Ns. The obtained results can be used as the criteria for further research in special education and rehabilitation, medical and professional rehabilitation.

  13. Grip type and task goal modify reach-to-grasp performance in post-stroke hemiparesis

    Science.gov (United States)

    Schaefer, Sydney Y.; DeJong, Stacey L.; Cherry, Kendra M.; Lang, Catherine E.

    2011-01-01

    This study investigated whether grip type and/or task goal influenced reaching and grasping performance in post-stroke hemiparesis. Sixteen adults with post-stroke hemiparesis and twelve healthy adults reached to and grasped a cylindrical object using one of two grip types (3-finger or palmar) to achieve one of two task goals (hold or lift). Performance of the stroke group was characteristic of hemiparetic limb movement during reach-to-grasp, with more curved handpaths and slower velocities compared to the control group. These effects were present regardless of grip type or task goal. Other measures of reaching (reach time and reach velocity at object contact) and grasping (peak thumb-index finger aperture during the reach and peak grip force during the grasp) were differentially affected by grip type, task goal, or both, despite the presence of hemiparesis, providing new evidence that changes in motor patterns after stroke may occur to compensate for stroke-related motor impairment. PMID:22357103

  14. Grip type and task goal modify reach-to-grasp performance in post-stroke hemiparesis.

    Science.gov (United States)

    Schaefer, Sydney Y; DeJong, Stacey L; Cherry, Kendra M; Lang, Catherine E

    2012-04-01

    This study investigated whether grip type and/or task goal influenced reaching and grasping performance in poststroke hemiparesis. Sixteen adults with poststroke hemiparesis and twelve healthy adults reached to and grasped a cylindrical object using one of two grip types (3-finger or palmar) to achieve one of two task goals (hold or lift). Performance of the stroke group was characteristic of hemiparetic limb movement during reach-to-grasp, with more curved handpaths and slower velocities compared with the control group. These effects were present regardless of grip type or task goal. Other measures of reaching (reach time and reach velocity at object contact) and grasping (peak thumb-index finger aperture during the reach and peak grip force during the grasp) were differentially affected by grip type, task goal, or both, despite the presence of hemiparesis, providing new evidence that changes in motor patterns after stroke may occur to compensate for stroke-related motor impairment.

  15. Gripping characteristics of an electromagnetically activated magnetorheological fluid-based gripper

    Science.gov (United States)

    Choi, Young T.; Hartzell, Christine M.; Leps, Thomas; Wereley, Norman M.

    2018-05-01

    The design and test of a magnetorheological fluid (MRF)-based universal gripper (MR gripper) are presented in this study. The MR gripper was developed to have a simple design, but with the ability to produce reliable gripping and handling of a wide range of simple objects. The MR gripper design consists of a bladder mounted atop an electromagnet, where the bladder is filled with an MRF, which was formulated to have long-term stable sedimentation stability, that was synthesized using a high viscosity linear polysiloxane (HVLP) carrier fluid with a carbonyl iron particle (CIP) volume fraction of 35%. Two bladders were fabricated: a magnetizable bladder using a magnetorheological elastomer (MRE), and a passive (non-magnetizable) silicone rubber bladder. The holding force and applied (initial compression) force of the MR gripper for a bladder fill volume of 75% were experimentally measured, for both magnetizable and passive bladders, using a servohydraulic material testing machine for a range of objects. The gripping performance of the MR gripper using an MRE bladder was compared to that of the MR gripper using a passive bladder.

  16. Why pens have rubbery grips

    Science.gov (United States)

    Dzidek, Brygida; Bochereau, Séréna; Johnson, Simon A.; Hayward, Vincent; Adams, Michael J.

    2017-10-01

    The process by which human fingers gives rise to stable contacts with smooth, hard objects is surprisingly slow. Using high-resolution imaging, we found that, when pressed against glass, the actual contact made by finger pad ridges evolved over time following a first-order kinetics relationship. This evolution was the result of a two-stage coalescence process of microscopic junctions made between the keratin of the stratum corneum of the skin and the glass surface. This process was driven by the secretion of moisture from the sweat glands, since increased hydration in stratum corneum causes it to become softer. Saturation was typically reached within 20 s of loading the contact, regardless of the initial moisture state of the finger and of the normal force applied. Hence, the gross contact area, frequently used as a benchmark quantity in grip and perceptual studies, is a poor reflection of the actual contact mechanics that take place between human fingers and smooth, impermeable surfaces. In contrast, the formation of a steady-state contact area is almost instantaneous if the counter surface is soft relative to keratin in a dry state. It is for this reason that elastomers are commonly used to coat grip surfaces.

  17. Grasping an augmented object to analyse manipulative force control.

    Science.gov (United States)

    Kawai, Satoru; Summers, Valerie A; Mackenzie, Christine L; Ivens, Chris J; Yamamoto, Takashi

    2002-12-15

    Augmented reality allows changes to be made to the visual perception of object size even while the tangible components remain completely unaltered. It was, therefore, utilized in a study whose results are being reported here to provide the proper environment required to thoroughly observe the exact effect that visual change to object size had on programming fingertip forces when objects were lifted with a precision grip. Twenty-one participants performed repeated lifts of an identical grip apparatus to a height of 20 mm, maintained each lift for 8 seconds, and then replaced the grip apparatus on the table. While all other factors of the grip apparatus remained unchanged, visual appearance was altered graphically in a 3-D augmented environment. The grip apparatus measured grip and load forces independently. Grip and load forces demonstrated significant rates of increase as well as peak forces as the size of graphical images increased; an aspect that occurred in spite of the fact that extraneous haptic information remained constant throughout the trials. By indicating a human tendency to rely - even unconsciously - on visual input to program the forces in the initial lifting phase, this finding provides further confirmation of previous research findings obtained in the physical environment; including the possibility of extraneous haptic effects (Gordon et al. 1991a, Mon-Williams and Murray 2000, Kawai et al. 2000). The present results also suggest that existing knowledge concerning human manipulation tasks in the physical world may be applied to an augmented environment where the physical objects are enhanced by computer generated visual components.

  18. Precision grip in congenital and acquired hemiparesis: similarities in impairments and implications for neurorehabilitation - review

    Directory of Open Access Journals (Sweden)

    Yannick eBleyenheuft

    2014-06-01

    Full Text Available Background: Patients with congenital and acquired hemiparesis incur long-term functional deficits, among which the loss of prehension that may impact their functional independence. Identifying, understanding and comparing the underlying mechanisms of prehension impairments represent an opportunity to better adapt neurorehabilitationObjective: The present review aims to provide a better understanding of precision grip deficits in congenital and acquired hemiparesis and to determine whether the severity and type of fine motor control impairments depend on whether or not the lesions are congenital or acquired in adulthood. Methods: Using combinations of the following key words: fingertip force, grip force, precision grip, cerebral palsy, stroke, pubmed and Scopus databases were used to search studies from 1984 to 2013. Results: Individuals with both congenital and acquired hemiparesis were able to some extent to use anticipatory motor control in precision grip tasks, even if this control was impaired in the paretic hand. In both congenital or acquired hemiparesis, the ability to plan efficient anticipatory motor control when the less-affected hand is used provides a possibility to remediate impairments in anticipatory motor control of the paretic hand. Conclusion: Surprisingly we observed very few differences between the results of studies in children with congenital hemiplegia and stroke patients. We suggest that the underlying specific strategies of neurorehabilitation developed for each one could benefit the other.

  19. GRIP CAMPAIGN REPORTS V1

    Data.gov (United States)

    National Aeronautics and Space Administration — The GRIP Campaign Reports dataset consists of various reports filed by scientists during the GRIP campaign which took place 8/15/2010 - 9/30/2010; however, several...

  20. Road grip test in Arjeplog

    OpenAIRE

    Engström, Niclas; Andrén, Henrik; Nybacka, Mikael; Fransson, Lennart; Larsson, Roland

    2008-01-01

    The Swedish road administration sees a need to improve the road grip estimation capacity for the Swedish road system. The challenge is to find methods to measure road grip fast and reliable. There where six different system types at the tests in Arjeplog, three continuous, two system measuring road grip through deceleration and one system based on GPS and accelerometers. Two system types used air craft runway tires. The other systems used either studded winter tires or friction winter tires. ...

  1. Effect of skin hydration on the dynamics of fingertip gripping contact.

    Science.gov (United States)

    André, T; Lévesque, V; Hayward, V; Lefèvre, P; Thonnard, J-L

    2011-11-07

    The dynamics of fingertip contact manifest themselves in the complex skin movements observed during the transition from a stuck state to a fully developed slip. While investigating this transition, we found that it depended on skin hydration. To quantify this dependency, we asked subjects to slide their index fingertip on a glass surface while keeping the normal component of the interaction force constant with the help of visual feedback. Skin deformation inside the contact region was imaged with an optical apparatus that allowed us to quantify the relative sizes of the slipping and sticking regions. The ratio of the stuck skin area to the total contact area decreased linearly from 1 to 0 when the tangential force component increased from 0 to a maximum. The slope of this relationship was inversely correlated to the normal force component. The skin hydration level dramatically affected the dynamics of the contact encapsulated in the course of evolution from sticking to slipping. The specific effect was to reduce the tendency of a contact to slip, regardless of the variations of the coefficient of friction. Since grips were more unstable under dry skin conditions, our results suggest that the nervous system responds to dry skin by exaggerated grip forces that cannot be simply explained by a change in the coefficient of friction.

  2. Muscle Fatigue in the Three Heads of the Triceps Brachii During a Controlled Forceful Hand Grip Task with Full Elbow Extension Using Surface Electromyography.

    Science.gov (United States)

    Ali, Asraf; Sundaraj, Kenneth; Badlishah Ahmad, R; Ahamed, Nizam Uddin; Islam, Anamul; Sundaraj, Sebastian

    2015-06-27

    The objective of the present study was to investigate the time to fatigue and compare the fatiguing condition among the three heads of the triceps brachii muscle using surface electromyography during an isometric contraction of a controlled forceful hand grip task with full elbow extension. Eighteen healthy subjects concurrently performed a single 90 s isometric contraction of a controlled forceful hand grip task and full elbow extension. Surface electromyographic signals from the lateral, long and medial heads of the triceps brachii muscle were recorded during the task for each subject. The changes in muscle activity among the three heads of triceps brachii were measured by the root mean square values for every 5 s period throughout the total contraction period. The root mean square values were then analysed to determine the fatiguing condition for the heads of triceps brachii muscle. Muscle fatigue in the long, lateral, and medial heads of the triceps brachii started at 40 s, 50 s, and 65 s during the prolonged contraction, respectively. The highest fatiguing rate was observed in the long head (slope = -2.863), followed by the medial head (slope = -2.412) and the lateral head (slope = -1.877) of the triceps brachii muscle. The results of the present study concurs with previous findings that the three heads of the triceps brachii muscle do not work as a single unit, and the fiber type/composition is different among the three heads.

  3. Precision grip responses to unexpected rotational perturbations scale with axis of rotation.

    Science.gov (United States)

    De Gregorio, Michael; Santos, Veronica J

    2013-04-05

    It has been established that rapid, pulse-like increases in precision grip forces ("catch-up responses") are elicited by unexpected translational perturbations and that response latency and strength scale according to the direction of linear slip relative to the hand as well as gravity. To determine if catch-up responses are elicited by unexpected rotational perturbations and are strength-, axis-, and/or direction-dependent, we imposed step torque loads about each of two axes which were defined relative to the subject's hand: the distal-proximal axis away from and towards the subject's palm, and the grip axis which connects the two fingertips. Precision grip responses were dominated initially by passive mechanics and then by active, unimodal catch-up responses. First dorsal interosseous activity, marking the start of the catch-up response, began 71-89 ms after the onset of perturbation. The onset latency, shape, and duration (217-231 ms) of the catch-up response were not affected by the axis, direction, or magnitude of the rotational perturbation, while strength was scaled by axis of rotation and slip conditions. Rotations about the grip axis that tilted the object away from the palm and induced rotational slip elicited stronger catch-up responses than rotations about the distal-proximal axis that twisted the object between the digits. To our knowledge, this study is the first to investigate grip responses to unexpected torque loads and to show characteristic, yet axis-dependent, catch-up responses for conditions other than pure linear slip. Copyright © 2013 Elsevier Ltd. All rights reserved.

  4. Gripping means for fuel assemblies of nuclear reactor

    International Nuclear Information System (INIS)

    Batjukov, V.I.; Fadeev, A.I.; Shkhian, T.G.; Vjugov, O.N.

    1980-01-01

    The proposed gripping means for fuel assemblies of a nuclear reactor comprises a housing, whereupon there is movably mounted a slider provided with longitudinally extending slots to receive gripping jaws whose tails are pivotably secured to the housing of the gripping means. On one side, the end faces of the longitudinally extending slots are slanted with respect to the longitudinal axis of the gripping means and come in contact with the teeth of the gripping jaws provided on the end which is opposite to the tail, whereby the jaws open as the slider and housing of the gripping means moves relative to each other so that the teeth are received in an internal groove provided in the head of the fuel assembly

  5. Hand grip strength

    DEFF Research Database (Denmark)

    Frederiksen, Henrik; Gaist, David; Petersen, Hans Christian

    2002-01-01

    in life is a major problem in terms of prevalence, morbidity, functional limitations, and quality of life. It is therefore of interest to find a phenotype reflecting physical functioning which has a relatively high heritability and which can be measured in large samples. Hand grip strength is known......-55%). A powerful design to detect genes associated with a phenotype is obtained using the extreme discordant and concordant sib pairs, of whom 28 and 77 dizygotic twin pairs, respectively, were found in this study. Hence grip strength is a suitable phenotype for identifying genetic variants of importance to mid...

  6. Writing forces associated with four pencil grasp patterns in grade 4 children.

    Science.gov (United States)

    Schwellnus, Heidi; Carnahan, Heather; Kushki, Azadeh; Polatajko, Helene; Missiuna, Cheryl; Chau, Tom

    2013-01-01

    OBJECTIVE. We investigated differences in handwriting kinetics, speed, and legibility among four pencil grasps after a 10-min copy task. METHOD. Seventy-four Grade 4 students completed a handwriting assessment before and after a copy task. Grip and axial forces were measured with an instrumented stylus and force-sensitive tablet. We used multiple linear regression to analyze the relationship between grasp pattern and grip and axial forces. RESULTS. We found no kinetic differences among grasps, whether considered individually or grouped by the number of fingers on the barrel. However, when grasps were grouped according to the thumb position, the adducted grasps exhibited higher mean grip and axial forces. CONCLUSION. Grip forces were generally similar across the different grasps. Kinetic differences resulting from thumb position seemed to have no bearing on speed and legibility. Interventions for handwriting difficulties should focus more on speed and letter formation than on grasp pattern. Copyright © 2013 by the American Occupational Therapy Association, Inc.

  7. Studying hand grip strength development among students who have taken tennis and massage courses

    Directory of Open Access Journals (Sweden)

    Erzeybek Mustafa Said

    2017-01-01

    Full Text Available In this study, the finger and hand force developments of the students who have taken selective/applied Tennis and Massage courses at the University have been examined. From the students of the Department of Physical Education and Sport, 19 healthy females and 73 healthy males (age = 21.25 ± 1.55 years (average ± SD who have taken selective Tennis courses;51 healthy males (age = 22.00 ± 1.04 years (average ± SD who have taken Massage courses; and as the control group,16 healthy womenand50 healthy males(age = 21.72 ± 1.47 years (average ± SD have been participated to the study. The age, length, body weight, grip strength of both hands as well as the finger grip strength of the subjects have been recorded. The course schedule has been set as once a week four hours practice for both tennis and massage. Two weeks of the education and training program that takes twelve weeks in total were assigned for theoretical classes. The remaining period of ten weeks was for practice classes and the measurements were performed before and after this ten weeks period. The hand grip strength measurement has been carried out with a Takkei branded hand dynamometer whereas for the measurement of the finger grip strength, a Baseline branded pinch meter has been used. For both the pre-test and final test of the finger grip and hand grip strength measurements, the paired sample t test has been used in terms of in-group comparisons, whereas for the inter-group comparisons, one-way ANOVA has been used. For the significant F values, post hoc Tukey test has been used. The right hand and the left hand grip values of both test groups as well as the values of the control group have been significantly increased between the pre-test and final test. Particularly, preferring the exercises that improve the hand and finger grip strengths would enable a better racket handle grip as well as an improved shot efficiency for tennis. This would also enable masseurs/masseuses to apply

  8. Determination the validity of the new developed Sport Experts® hand grip dynamometer, measuring continuity of force, and comparison with current Takei and Baseline® dynamometers.

    Science.gov (United States)

    Güçlüöver, A; Kutlu, M; Ciğerci, A E; Esen, H T; Demirkan, E; Erdoğdu, M

    2015-11-01

    In this study the Sport Experts ™ brand of hand grip dynamometer, measuring the continuity of force with the new developed load cell technology, was compared with Takei and Baseline® dynamometers, the current in use. It was tried to determine the correlation between them. In a study with provides use of clinical, orthopedic and rehabilitative purposes in the athletes and patient populations, this developed dynamometer can provide useful data by observing the continuity of force. The sample of the study included 60 badminton players in 2010-2011; consisting of Turkish Junior National male players (N.=16, age: 16.8±1.5), Junior National female players (N.=14, age: 16.9±1.6), amateur level male players (N.=15, age: 16.3±0.8) and amateur level female players (N.=15, age: 16.1±0.6). ANOVA was used in the statistical methods in order to compare the hand grip strength made by different brands; Pearson's correlation coefficient was used to determine the relationship level between dynamometers. Furthermore, test-retest reliability analysis was completed the new developed expert dynamometer. There was no statistically significant difference in the comparison of the dynamometers (P>0.05). Besides, a highly significant relationship (r=0.95 to 0.96) was found among all three dynamometers. However, the reliability coefficient was found (Chronbachs α: 0.989, ICC:0.97, r=0.97), (Pexpert dynamometer. Comparison between the dynamometers and the statistical results obtained from the correlation relationships shows interchangeability of dynamometers. As a result, our observation of force continuity (progression) of the athlete and patient populations is thought to be important.

  9. Superposition of automatic and voluntary aspects of grip force control in humans during object manipulation.

    Directory of Open Access Journals (Sweden)

    Frederic Danion

    Full Text Available When moving grasped objects, people automatically modulate grip force (GF with movement-dependent load force (LF in order to prevent object slip. However, GF can also be modulated voluntarily as when squeezing an object. Here we investigated possible interactions between automatic and voluntary GF control. Participants were asked to generate horizontal cyclic movements (between 0.6 and 2.0 Hz of a hand-held object that was restrained by an elastic band such that the load force (LF reached a peak once per movement cycle, and to simultaneously squeeze the object at each movement reversal (i.e., twice per cycle. Participants also performed two control tasks in which they either only moved (between 0.6 and 2.0 Hz or squeezed (between 1.2 and 4.0 Hz the object. The extent to which GF modulation in the simultaneous task could be predicted from the two control tasks was assessed using power spectral analyses. At all frequencies, the GF power spectra from the simultaneous task exhibited two prominent components that occurred at the cycle frequency (ƒ and at twice this frequency (2ƒ, whereas the spectra from the movement and squeeze control task exhibited only single peaks at ƒ and 2ƒ, respectively. At lower frequencies, the magnitudes of both frequency components in the simultaneous task were similar to the magnitudes of the corresponding components in the control tasks. However, as frequency increased, the magnitudes of both components in the simultaneous task were greater than the magnitudes of the corresponding control task components. Moreover, the phase relationship between the ƒ components of GF and LF began to drift from the value observed in the movement control task. Overall these results suggest that, at lower movement frequencies, voluntary and automatic GF control processes operate at different hierarchical levels. Several mechanisms are discussed to account for interaction effects observed at higher movement frequencies.

  10. The Effects of Industrial Protective Gloves and Hand Skin Temperatures on Hand Grip Strength and Discomfort Rating.

    Science.gov (United States)

    Ramadan, Mohamed Z

    2017-12-04

    Daily working activities and functions require a high contribution of hand and forearm muscles in executing grip force. To study the effects of wearing different gloves on grip strength, under a variety of hand skin temperatures, an assessment of the maximum grip strength was performed with 32 healthy male workers with a mean age (standard deviation) of 30.44 (5.35) years wearing five industrial gloves at three hand skin temperatures. Their ages and anthropometric characteristics including body mass index (BMI), hand length, hand width, hand depth, hand palm, and wrist circumference were measured. The hand was exposed to different bath temperatures (5 °C, 25 °C, and 45 °C) and hand grip strength was measured using a Jamar hydraulic hand dynamometer with and without wearing the gloves (chemical protection glove, rubber insulating glove, anti-vibration impact glove, cotton yarn knitted glove, and RY-WG002 working glove). The data were analyzed using the Shapiro-Wilk test, Pearson correlation coefficient, Tukey test, and analysis of variance (ANOVA) of the within-subject design analysis. The results showed that wearing gloves significantly affected the maximum grip strength. Wearing the RY-WG002 working glove produced a greater reduction on the maximum grip when compared with the bare hand, while low temperatures (5 °C) had a significant influence on grip when compared to medium (25 °C) and high (45 °C) hand skin temperatures. In addition, participants felt more discomfort in both environmental extreme conditions. Furthermore, they reported more discomfort while wearing neoprene, rubber, and RY-WG002 working gloves.

  11. Grip Strength Survey Based on Hand Tool Usage

    Directory of Open Access Journals (Sweden)

    Erman ÇAKIT

    2016-12-01

    Full Text Available Hand grip strength is broadly used for performing tasks involving equipment in production and processing activities. Most professionals in this field rely on grip strength to perform their tasks. There were three main aims of this study: i determining various hand grip strength measurements for the group of hand tool users, ii investigating the effects of height, weight, age, hand dominance, body mass index, previous Cumulative Trauma Disorder (CTD diagnosis, and hand tool usage experience on hand grip strength, and iii comparing the obtained results with existing data for other populations. The study groups comprised 71 healthy male facility workers. The values of subjects’ ages was observed between 26 and 74 years. The data were statistically analyzed to assess the normality of data and the percentile values of grip strength. The results of this study demonstrate that there were no significance differences noted between dominant and non-dominant hands. However, there were highly significant differences between the CTD group and the other group. Hand grip strength for the dominant hand was positively correlated to height, weight, and body mass index, and negatively correlated to age and tool usage experience. Hand dominance, height, weight, body mass index, age and tool usage experience should be considered when establishing normal values for grip strength.

  12. Muscular forearm activation in hand-grip tasks with superimposition of mechanical vibrations.

    Science.gov (United States)

    Fattorini, L; Tirabasso, A; Lunghi, A; Di Giovanni, R; Sacco, F; Marchetti, E

    2016-02-01

    The purpose of this paper is to evaluate the muscular activation of the forearm, with or without vibration stimuli at different frequencies while performing a grip tasks of 45s at various level of exerted force. In 16 individuals, 9 females and 7 males, the surface electromyogram (EMG) of extensor carpi radialis longus and the flexor carpi ulnari muscles were assessed. At a short latency from onset EMG, RMS and the level of MU synchronization were assessed to evaluate the muscular adaptations. Whilst a trend of decay of EMG Median frequency (MDFd) was employed as an index of muscular fatigue. Muscular tasks consists of the grip of an instrumented handle at a force level of 20%, 30%, 40%, 60% of the maximum voluntary force. Vibration was supplied by a shaker to the hand in mono-frequential waves at 20, 30, 33 and 40Hz. In relation to EMG, RMS and MU synchronization, the muscular activation does not seem to change with the superimposition of the mechanical vibrations, on the contrary a lower MDFd was observed at 33Hz than in absence of vibration. This suggests an early muscular fatigue induced by vibration due to the fact that 33Hz is a resonance frequency for the hand-arm system. Copyright © 2015 Elsevier Ltd. All rights reserved.

  13. Serotonin and Histamine Therapy Increases Tetanic Forces of Myoblasts, Reduces Muscle Injury, and Improves Grip Strength Performance of Dmdmdx Mice

    Directory of Open Access Journals (Sweden)

    Volkan Gurel

    2015-11-01

    Full Text Available Duchenne muscular dystrophy (DMD is a recessive X-linked fatal disorder caused by a mutation in the dystrophin gene. Although several therapeutic approaches have been studied, none has led to substantial long-term effects in patients. The aim of this study was to test a serotonin and histamine (S&H combination on human skeletal myoblasts and Dmdmdx mice for its effects on muscle strength and injury. Normal human bioartificial muscles (BAMs were treated, and muscle tetanic forces and muscle injury tests were performed using the MyoForce Analysis System. Dmdmdx mice, the murine model of DMD, were administered serotonin, histamine, or S&H combination twice daily for 6 weeks, and functional performance tests were conducted once a week. The S&H combination treatment caused significant increases in tetanic forces at all time points and concentrations tested as compared to the saline controls. Dose response of the BAMs to the treatment demonstrated a significant increase in force generation at all concentrations compared to the controls after 3 to 4 days of drug treatment. The highest 3 concentrations had a significant effect on lowering contractile-induced injury as measured by a reduction in the release of adenylate kinase. Histamine-only and S&H treatments improved grip strength of Dmdmdx mice, whereas serotonin-only treatment resulted in no significant improvement in muscle strength. The results of this study indicate that S&H therapy might be a promising new strategy for muscular dystrophies and that the mechanism should be further investigated.

  14. G×E Interaction Influences Trajectories of Hand Grip Strength

    DEFF Research Database (Denmark)

    Petersen, Inge; Pedersen, Nancy L; Rantanen, Taina

    2016-01-01

    Age-related decline in grip strength predicts later life disability, frailty, lower well-being and cognitive change. While grip strength is heritable, genetic influence on change in grip strength has been relatively ignored, with non-shared environmental influence identified as the primary contri...

  15. The handyman's brain: a neuroimaging meta-analysis describing the similarities and differences between grip type and pattern in humans.

    Science.gov (United States)

    King, M; Rauch, H G; Stein, D J; Brooks, S J

    2014-11-15

    Handgrip is a ubiquitous human movement that was critical in our evolution. However, the differences in brain activity between grip type (i.e. power or precision) and pattern (i.e. dynamic or static) are not fully understood. In order to address this, we performed Activation Likelihood Estimation (ALE) analysis between grip type and grip pattern using functional magnetic resonance imaging (fMRI) data. ALE provides a probabilistic summary of the BOLD response in hundreds of subjects, which is often beyond the scope of a single fMRI experiment. We collected data from 28 functional magnetic resonance data sets, which included a total of 398 male and female subjects. Using ALE, we analyzed the BOLD response during power, precision, static and dynamic grip in a range of forces and age in right handed healthy individuals without physical impairment, cardiovascular or neurological dysfunction using a variety of grip tools, feedback and experimental training. Power grip generates unique activation in the postcentral gyrus (areas 1 and 3b) and precision grip generates unique activation in the supplementary motor area (SMA, area 6) and precentral gyrus (area 4a). Dynamic handgrip generates unique activation in the precentral gyrus (area 4p) and SMA (area 6) and of particular interest, both dynamic and static grip share activation in the area 2 of the postcentral gyrus, an area implicated in the evolution of handgrip. According to effect size analysis, precision and dynamic grip generates stronger activity than power and static, respectively. Our study demonstrates specific differences between grip type and pattern. However, there was a large degree of overlap in the pre and postcentral gyrus, SMA and areas of the frontal-parietal-cerebellar network, which indicates that other mechanisms are potentially involved in regulating handgrip. Further, our study provides empirically based regions of interest, which can be downloaded here within, that can be used to more effectively

  16. Physical Profiling Performance of Air Force Primary Care Providers

    Science.gov (United States)

    2017-08-09

    AFRL-SA-WP-TR-2017-0014 Physical Profiling Performance of Air Force Primary Care Providers Anthony P. Tvaryanas1; William P...COVERED (From – To) September 2016 – January 2017 4. TITLE AND SUBTITLE Physical Profiling Performance of Air Force Primary Care Providers...encounter with their primary care team. An independent medical standards subject matter expert (SME) reviewed encounters in the electronic health record

  17. The Effects of Industrial Protective Gloves and Hand Skin Temperatures on Hand Grip Strength and Discomfort Rating

    Directory of Open Access Journals (Sweden)

    Mohamed Z. Ramadan

    2017-12-01

    Full Text Available Daily working activities and functions require a high contribution of hand and forearm muscles in executing grip force. To study the effects of wearing different gloves on grip strength, under a variety of hand skin temperatures, an assessment of the maximum grip strength was performed with 32 healthy male workers with a mean age (standard deviation of 30.44 (5.35 years wearing five industrial gloves at three hand skin temperatures. Their ages and anthropometric characteristics including body mass index (BMI, hand length, hand width, hand depth, hand palm, and wrist circumference were measured. The hand was exposed to different bath temperatures (5 °C, 25 °C, and 45 °C and hand grip strength was measured using a Jamar hydraulic hand dynamometer with and without wearing the gloves (chemical protection glove, rubber insulating glove, anti-vibration impact glove, cotton yarn knitted glove, and RY-WG002 working glove. The data were analyzed using the Shapiro–Wilk test, Pearson correlation coefficient, Tukey test, and analysis of variance (ANOVA of the within-subject design analysis. The results showed that wearing gloves significantly affected the maximum grip strength. Wearing the RY-WG002 working glove produced a greater reduction on the maximum grip when compared with the bare hand, while low temperatures (5 °C had a significant influence on grip when compared to medium (25 °C and high (45 °C hand skin temperatures. In addition, participants felt more discomfort in both environmental extreme conditions. Furthermore, they reported more discomfort while wearing neoprene, rubber, and RY-WG002 working gloves.

  18. Biometric verification based on grip-pattern recognition

    NARCIS (Netherlands)

    Veldhuis, Raymond N.J.; Bazen, A.M.; Kauffman, J.A.; Hartel, Pieter H.; Delp, Edward J.; Wong, Ping W.

    This paper describes the design, implementation and evaluation of a user-verification system for a smart gun, which is based on grip-pattern recognition. An existing pressure sensor consisting of an array of 44 x 44 piezoresistive elements is used to measure the grip pattern. An interface has been

  19. Biometric verification based on grip-pattern recognition

    NARCIS (Netherlands)

    Veldhuis, Raymond N.J.; Bazen, A.M.; Kauffman, J.A.; Hartel, Pieter H.

    This paper describes the design, implementation and evaluation of a user-verification system for a smart gun, which is based on grip-pattern recognition. An existing pressure sensor consisting of an array of 44 £ 44 piezoresistive elements is used to measure the grip pattern. An interface has been

  20. Tyre-road grip coefficient assessment - Part II: online estimation using instrumented vehicle, extended Kalman filter, and neural network

    Science.gov (United States)

    Luque, Pablo; Mántaras, Daniel A.; Fidalgo, Eloy; Álvarez, Javier; Riva, Paolo; Girón, Pablo; Compadre, Diego; Ferran, Jordi

    2013-12-01

    The main objective of this work is to determine the limit of safe driving conditions by identifying the maximal friction coefficient in a real vehicle. The study will focus on finding a method to determine this limit before reaching the skid, which is valuable information in the context of traffic safety. Since it is not possible to measure the friction coefficient directly, it will be estimated using the appropriate tools in order to get the most accurate information. A real vehicle is instrumented to collect information of general kinematics and steering tie-rod forces. A real-time algorithm is developed to estimate forces and aligning torque in the tyres using an extended Kalman filter and neural networks techniques. The methodology is based on determining the aligning torque; this variable allows evaluation of the behaviour of the tyre. It transmits interesting information from the tyre-road contact and can be used to predict the maximal tyre grip and safety margin. The maximal grip coefficient is estimated according to a knowledge base, extracted from computer simulation of a high detailed three-dimensional model, using Adams® software. The proposed methodology is validated and applied to real driving conditions, in which maximal grip and safety margin are properly estimated.

  1. Grip force and heart rate responses to manual carrying tasks: effects of material, weight, and base area of the container.

    Science.gov (United States)

    Lee, Tzu-Hsien; Tseng, Chia-Yun

    2014-01-01

    This study recruited 16 industrial workers to examine the effects of material, weight, and base area of container on reduction of grip force (ΔGF) and heart rate for a 100-m manual carrying task. This study examined 2 carrying materials (iron and water), 4 carrying weights (4.4, 8.9, 13.3, 17.8 kg), and 2 base areas of container (24 × 24 cm, 35 × 24 cm). This study showed that carrying water significantly increased ΔGF and heart rate as compared with carrying iron. Also, ΔGF and heart rate significantly increased with carrying weight and base area of container. The effects of base area of container on ΔGF and heart rate were greater in carrying water condition than in carrying iron condition. The maximum dynamic effect of water on ΔGF and heart rate occurred when water occupied ~60%-80% of full volume of the container.

  2. Interpreting Power-Force-Velocity Profiles for Individualized and Specific Training.

    Science.gov (United States)

    Morin, Jean-Benoît; Samozino, Pierre

    2016-03-01

    Recent studies have brought new insights into the evaluation of power-force-velocity profiles in both ballistic push-offs (eg, jumps) and sprint movements. These are major physical components of performance in many sports, and the methods the authors developed and validated are based on data that are now rather simple to obtain in field conditions (eg, body mass, jump height, sprint times, or velocity). The promising aspect of these approaches is that they allow for more individualized and accurate evaluation, monitoring, and training practices, the success of which is highly dependent on the correct collection, generation, and interpretation of athletes' mechanical outputs. The authors therefore wanted to provide a practical vade mecum to sports practitioners interested in implementing these power-force-velocity-profiling approaches. After providing a summary of theoretical and practical definitions for the main variables, the authors first detail how vertical profiling can be used to manage ballistic push-off performance, with emphasis on the concept of optimal force-velocity profile and the associated force-velocity imbalance. Furthermore, they discuss these same concepts with regard to horizontal profiling in the management of sprinting performance. These sections are illustrated by typical examples from the authors' practice. Finally, they provide a practical and operational synthesis and outline future challenges that will help further develop these approaches.

  3. Muscle response to pneumatic hand tool torque reaction forces.

    Science.gov (United States)

    Radwin, R G; VanBergeijk, E; Armstrong, T J

    1989-06-01

    Surface electromyography was used for studying the effects of torque reaction force acting against the hand, on forearm muscle activity and grip force for five subjects operating right angle, air shut-off nutrunners. Four tools having increasing spindle torque were operated using short and long torque reaction times. Nutrunner spindle torque ranged between 30 Nm and 100 Nm. Short torque reaction time was considered 0.5 s while long torque reaction time was 2 s. Peak horizontal force was the greatest component of the reaction force acting against the hand and accounted for more than 97% of the peak resultant hand force. Peak hand force increased from 89 N for the smallest tool to 202 N for the largest tool. Forearm muscle rms EMG, scaled for grip force, indicated average flexor activity during the Torque-reaction phase was more than four times greater than the Pre-start and Post Shut-off phases, and two times greater than the Run-down phase. Flexor EMG activity during the Torque-reaction phase increased for increasing tool peak spindle torque. Average flexor rms EMG activity, scaled for grip force, during the Torque-reaction phase increased from 372 N for the 30 Nm nutrunner to 449 N for the 100 Nm nutrunner. Flexor rms EMG activity averaged during the Torque-reaction phase and scaled for grip force was 390 N for long torque reaction times and increased to 440 N for short torque reaction times. Flexor rms EMG integrated over the torque reaction phase was 839 Ns for long torque reaction times and decreased to 312 Ns for short torque reaction times. The average latency between tool spindle torque onset and peak initial flexor rms EMG for long torque reaction times was 294 ms which decreased to 161 ms for short torque reaction times. The average latency between peak tool spindle torque, just prior to tool shut-off, and peak final rms EMG for long torque reaction times was 97 ms for flexors and 188 ms for extensors, which decreased for short torque reaction times to 47

  4. A COMPARATIVE STUDY TO FIND OUT IMMEDIATE EFFECTIVENESS OF MOVEMENT WITH MOBILIZATION VERSUS ELBOW ORTHOSIS ON PAIN AND GRIP STRENGTH IN LATERAL EPICONDYLITIS IN HOUSEWIVES

    Directory of Open Access Journals (Sweden)

    Trishna Kakati

    2015-12-01

    both Mulligan’s MWM technique and counter force elbow orthosis produces significant decrease in pain and improvement in grip strength immediately after treatment. It has been seen that Mulligan’s MWM is better than counter force elbow orthosis in relieving pain (p=0.03. Increase in hand grip strength does not differ remarkably in both treatment groups.

  5. The interdigital brace and other grips for termite nest perforation by chimpanzees of the Goualougo Triangle, Republic of Congo.

    Science.gov (United States)

    Lesnik, Julie J; Sanz, Crickette M; Morgan, David B

    2015-06-01

    Studies of chimpanzee termite foraging enlighten our understanding of early hominin tool use not only by modeling the cognitive ability of our ancestors but also by emphasizing the possible role of social insects in the hominin diet. The chimpanzees of the Goualougo Triangle are known to have one of the largest and most complex tool repertoires reported for wild chimpanzees. One tool set habitually used by this population includes a perforating tool to penetrate the hard outer crust of elevated termite nests before fishing for termite prey with an herbaceous stem. Here, we report the variation present in the grips used on the perforating tool. Our analysis of video recordings of chimpanzee visitation to termite nests over a 3-year period shows that these chimpanzees use a variety of grips to navigate the challenges encountered in opening a termite nest. For situations in which the soil is most hardened, perforating requires force and a power grip is often used. When the soil in the passageway is loose, precision grips are suitable for the task. One of the preferred grips reported here is an interdigital brace, which has previously been described in studies of how some people hold a pencil. In this study, for the first time, the interdigital brace has been thoroughly described for chimpanzees. The various strategies and grips used during perforation emphasize the importance of termites as a nutritional resource that should be considered more strongly as a food used by early hominins. © 2015 Wiley Periodicals, Inc.

  6. Thimble grip fuel assembly handling tool

    International Nuclear Information System (INIS)

    Salton, R.B.; Hornak, L.P.; Marshall, J.R.; Meuschke, R.E.

    1989-01-01

    This patent describes an apparatus for lifting a fuel assembly of a nuclear reactor. The fuel assembly consists of a top nozzle and control rod guide tubes. The apparatus having a gripping means comprised of: a life plate, an actuating plate having a plurality of apertures, the actuating plate disposed in spaced relationship below the lift plate and vertically movable relative thereto; gripping members operably associated with the lift and actuating plates, the gripping members comprising: (a) a vertical rod fixedly secured near its top end to the lift plate and projecting downward therefrom through an associated aperture in the actuating plate, the rod having a first frustoconical surface formed near its lower end, (b) a generally cylindrical, elastically deformable vertical sleeve having a bore therethrough with a first inner diameter, the sleeve having a first bevelled inside surface near the top end and a second bevelled inside surface at the bottom end of the sleeve, and (c) a vertical gripper actuator disposed about the rod

  7. GRIP DC-8 NAVIGATION AND HOUSEKEEPING DATA V1

    Data.gov (United States)

    National Aeronautics and Space Administration — The GRIP DC-8 Navigation and Housekeeping Data contains aircraft navigational data obtained during the GRIP campaign (15 Aug 2010 - 30 Sep 2010). The major goal was...

  8. Energy profile of nanobody-GFP complex under force

    Science.gov (United States)

    Klamecka, Kamila; Severin, Philip M.; Milles, Lukas F.; Gaub, Hermann E.; Leonhardt, Heinrich

    2015-10-01

    Nanobodies (Nbs)—the smallest known fully functional and naturally occuring antigen-binding fragments—have attracted a lot of attention throughout the last two decades. Exploring their potential beyond the current use requires more detailed characterization of their binding forces as those cannot be directly derived from the binding affinities. Here we used atomic force microscope to measure rupture force of the Nb-green fluorescent protein (GFP) complex in various pulling geometries and derived the energy profile characterizing the interaction along the direction of the pulling force. We found that—despite identical epitopes—the Nb binds stronger (41-56 pN) to enhanced GFP than to wild-type GFP (28-45 pN). Measured forces make the Nb-GFP pair a potent reference for investigating molecular forces in living systems both in and ex vivo.

  9. Energy profile of nanobody-GFP complex under force.

    Science.gov (United States)

    Klamecka, Kamila; Severin, Philip M; Milles, Lukas F; Gaub, Hermann E; Leonhardt, Heinrich

    2015-09-10

    Nanobodies (Nbs)-the smallest known fully functional and naturally occuring antigen-binding fragments-have attracted a lot of attention throughout the last two decades. Exploring their potential beyond the current use requires more detailed characterization of their binding forces as those cannot be directly derived from the binding affinities. Here we used atomic force microscope to measure rupture force of the Nb-green fluorescent protein (GFP) complex in various pulling geometries and derived the energy profile characterizing the interaction along the direction of the pulling force. We found that-despite identical epitopes-the Nb binds stronger (41-56 pN) to enhanced GFP than to wild-type GFP (28-45 pN). Measured forces make the Nb-GFP pair a potent reference for investigating molecular forces in living systems both in and ex vivo.

  10. Effects of oncoming target velocities on rapid force production and accuracy of force production intensity and timing.

    Science.gov (United States)

    Ohta, Yoichi

    2017-12-01

    The present study aimed to clarify the effects of oncoming target velocities on the ability of rapid force production and accuracy and variability of simultaneous control of both force production intensity and timing. Twenty male participants (age: 21.0 ± 1.4 years) performed rapid gripping with a handgrip dynamometer to coincide with the arrival of an oncoming target by using a horizontal electronic trackway. The oncoming target velocities were 4, 8, and 12 m · s -1 , which were randomly produced. The grip force required was 30% of the maximal voluntary contraction. Although the peak force (Pf) and rate of force development (RFD) increased with increasing target velocity, the value of the RFD to Pf ratio was constant across the 3 target velocities. The accuracy of both force production intensity and timing decreased at higher target velocities. Moreover, the intrapersonal variability in temporal parameters was lower in the fast target velocity condition, but constant variability in 3 target velocities was observed in force intensity parameters. These results suggest that oncoming target velocity does not intrinsically affect the ability for rapid force production. However, the oncoming target velocity affects accuracy and variability of force production intensity and timing during rapid force production.

  11. PICK1 interacts with ABP/GRIP to regulate AMPA receptor trafficking.

    Science.gov (United States)

    Lu, Wei; Ziff, Edward B

    2005-08-04

    PICK1 and ABP/GRIP bind to the AMPA receptor (AMPAR) GluR2 subunit C terminus. Transfer of the receptor from ABP/GRIP to PICK1, facilitated by GluR2 S880 phosphorylation, may initiate receptor trafficking. Here we report protein interactions that regulate these steps. The PICK1 BAR domain interacts intermolecularly with the ABP/GRIP linker II region and intramolecularly with the PICK1 PDZ domain. Binding of PKCalpha or GluR2 to the PICK1 PDZ domain disrupts the intramolecular interaction and facilitates the PICK1 BAR domain association with ABP/GRIP. Interference with the PICK1-ABP/GRIP interaction impairs S880 phosphorylation of GluR2 by PKC and decreases the constitutive surface expression of GluR2, the NMDA-induced endocytosis of GluR2, and recycling of internalized GluR2. We suggest that the PICK1 interaction with ABP/GRIP is a critical step in controlling GluR2 trafficking.

  12. Grip-pattern recognition: Applied to a smart gun

    NARCIS (Netherlands)

    Shang, X.

    2008-01-01

    In our work the verification performance of a biometric recognition system based on grip patterns, as part of a smart gun for use by the police ocers, has been investigated. The biometric features are extracted from a two-dimensional pattern of the pressure, exerted on the grip of a gun by the hand

  13. Comprehension of handwriting development: Pen-grip kinetics in handwriting tasks and its relation to fine motor skills among school-age children.

    Science.gov (United States)

    Lin, Yu-Chen; Chao, Yen-Li; Wu, Shyi-Kuen; Lin, Ho-Hsio; Hsu, Chieh-Hsiang; Hsu, Hsiao-Man; Kuo, Li-Chieh

    2017-10-01

    Numerous tools have been developed to evaluate handwriting performances by analysing written products. However, few studies have directly investigated kinetic performances of digits when holding a pen. This study thus attempts to investigate pen-grip kinetics during writing tasks of school-age children and explore the relationship between the kinetic factors and fine motor skills. This study recruited 181 children aged from 5 to 12 years old and investigated the effects of age on handwriting kinetics and the relationship between these and fine motor skills. The forces applied from the digits and pen-tip were measured during writing tasks via a force acquisition pen, and the children's fine motor performances were also evaluated. The results indicate that peak force and average force might not be direct indicators of handwriting performance for normally developing children at this age. Younger children showed larger force variation and lower adjustment frequency during writing, which might indicate they had poorer force control than the older children. Force control when handling a pen is significantly correlated with fine motor performance, especially in relation to the manual dexterity. A novel system is proposed for analysing school-age children's force control while handwriting. We observed the development of force control in relation to pen grip among the children with different ages in this study. The findings suggested that manipulation skill may be crucial when children are establishing their handwriting capabilities. © 2017 Occupational Therapy Australia.

  14. Energy profile of nanobody–GFP complex under force

    International Nuclear Information System (INIS)

    Klamecka, Kamila; Severin, Philip M; Milles, Lukas F; Gaub, Hermann E; Leonhardt, Heinrich

    2015-01-01

    Nanobodies (Nbs)—the smallest known fully functional and naturally occuring antigen-binding fragments—have attracted a lot of attention throughout the last two decades. Exploring their potential beyond the current use requires more detailed characterization of their binding forces as those cannot be directly derived from the binding affinities. Here we used atomic force microscope to measure rupture force of the Nb–green fluorescent protein (GFP) complex in various pulling geometries and derived the energy profile characterizing the interaction along the direction of the pulling force. We found that—despite identical epitopes—the Nb binds stronger (41–56 pN) to enhanced GFP than to wild-type GFP (28–45 pN). Measured forces make the Nb–GFP pair a potent reference for investigating molecular forces in living systems both in and ex vivo. (paper)

  15. Progress on the interface between UPP and CPRHS (Cask and Plug Remote Handling System) tractor/gripping tool for ITER

    International Nuclear Information System (INIS)

    Rosa, Elena V.; Rios, Luis; Queral, Vicente

    2013-01-01

    Highlights: ► UPP interface requirements in the plug RH extraction/insertion for ITER. ► Analyze of maximum misalignment between port duct and port cell. ► Friction study between plug skids and VV port/ramp rails during the plug transfer. ► Definition of the tolerance in the plug skids to avoid the plug jamming. ► Concepts of gripping tools based on one gripping point and avoiding force feedback. -- Abstract: EFDA finances a training programme called Goal Oriented Training Programme for Remote Handling (GOT RH), whose goal is to train engineers in Remote Handling for ITER. As part of this training programme, the conceptual design of the mechanical interface between Upper Port Plug (UPP) and Cask and Plug Remote Handling System (CPRHS) as well as the conceptual design of the needed tools for UPP Remote Handling is carried out. The paper presents the conceptual design of the UPP/Gripping Tool Interface. This includes the conceptual design of the gripping tool for introducing/removing the UPP in/from the ITER port and the mechanical features on both sides of the UPP/Gripping Tool Interface (e.g. alignment features, mechanical connectors, fasteners). In order to develop the design of the interface between UPP and CPRHS it is necessary to first identify the functional requirements of the Transfer Cask System (TCS) and the CPRHS, such as required degrees of freedom (DoF), required performances of system, geometrical constraints, loading conditions, alignment requirements, RAMI requirements. These requirements are the input data for the design of the interface between UPP and gripping tool and some of them are also described in the paper

  16. Interactive effects of music tempi and intensities on grip strength and subjective affect.

    Science.gov (United States)

    Karageorghis, C I; Cheek, P; Simpson, S D; Bigliassi, M

    2018-03-01

    Pretask music is widely used by athletes albeit there is scant empirical evidence to support its use. The present study extended a line of work into pretask music by examining the interactive effects of music tempo and intensity (volume) on the performance of a simple motor skill and subjective affect. A 2 × 2 within-subjects factorial design was employed with an additional no-music control, the scores from which were used as a covariate. A sample of 52 male athletes (M age  = 26.1 ± 4.8 years) was exposed to five conditions: fast/loud (126 bpm/80 dBA), fast/quiet (126 bpm/70 dBA), slow/loud (87 bpm/80 dBA), slow/quiet (87 bpm/70 dBA) music, and a no-music control. Dependent variables were grip strength, measured with a handgrip dynamometer, and subjective affect, assessed by use of the Affect Grid. The tempo and intensity components of music had interactive effects for grip strength but only main effects for subjective affect. Fast-tempo music played at a high intensity yielded the highest grip strength, while fast-tempo music played at a low-intensity resulted in much lower grip strength (M diff.  = -1.11 Force kg). For affective valence, there were main effects of tempo and intensity, with fast and loud music yielding the highest scores. For affective arousal, there was no difference between tempi although there was between intensities, with the high-intensity condition yielding higher scores. The present findings indicate the utility of fast/loud pretask music in enhancing affective valence and arousal in preparation for a simple or gross motor task. © 2017 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  17. Finger pressure adjustments to various object configurations during precision grip in humans and monkeys.

    Science.gov (United States)

    Viaro, Riccardo; Tia, Banty; Coudé, Gino; Canto, Rosario; Oliynyk, Andriy; Salmas, Paola; Masia, Lorenzo; Sandini, Giulio; Fadiga, Luciano

    2017-06-01

    In this study, we recorded the pressure exerted onto an object by the index finger and the thumb of the preferred hand of 18 human subjects and either hand of two macaque monkeys during a precision grasping task. The to-be-grasped object was a custom-made device composed by two plates which could be variably oriented by a motorized system while keeping constant the size and thus grip dimension. The to-be-grasped plates were covered by an array of capacitive sensors to measure specific features of finger adaptation, namely pressure intensity and centroid location and displacement. Kinematic measurements demonstrated that for human subjects and for monkeys, different plate configurations did not affect wrist velocity and grip aperture during the reaching phase. Consistently, at the instant of fingers-plates contact, pressure centroids were clustered around the same point for all handle configurations. However, small pressure centroid displacements were specifically adopted for each configuration, indicating that both humans and monkeys can display finger adaptation during precision grip. Moreover, humans applied stronger thumb pressure intensity, performed less centroid displacement and required reduced adjustment time, as compared to monkeys. These pressure patterns remain similar when different load forces were required to pull the handle, as ascertained by additional measurements in humans. The present findings indicate that, although humans and monkeys share common features in motor control of grasping, they differ in the adjustment of fingertip pressure, probably because of skill and/or morphology divergences. Such a precision grip device may form the groundwork for future studies on prehension mechanisms. © 2017 Federation of European Neuroscience Societies and John Wiley & Sons Ltd.

  18. The Effect of Dry Needling of the Trigger Points of Shoulder Muscles on Pain and Grip Strength in Patients with Lateral Epicondylitis: A Pilot Study

    Directory of Open Access Journals (Sweden)

    Alireza Kheradmandi

    2015-09-01

    Full Text Available Background: Lateral epicondylitis, also known as tennis elbow, is the most common overuse syndrome of the elbow. The severity of pain may not be directly caused by tendinopathy of wrist extensors since trigger points of the shoulder muscles have a referral zone in the arm and elbow. Therefore the aim of this study was to evaluate the effect of dry needling of shoulder myofascial trigger points on wrist extensors muscles pain and function. Methods: Fourteen female patients with tennis elbow (aged 20 - 45 years old were recruited after primary evaluation by an orthopedist. They entered the study if they had pain in the lateral aspect of elbow of the dominant hand for more than 3 months along with the presence of myofascial trigger points in any muscles of supra spinatus, infra spinatus, sub scapularis or scalenes. Pain pressure threshold, maximal grip force and pain intensity of the hand extensors on lateral epicondyle of elbow were measured before and after treatment. Pain intensity was measured on a one to ten scale of visual analogue scale (VAS. A hand dynamometer used to measure the maximal grip force value of the affected hand in 0˚shoulder flexion/ abduction, 90˚ elbow extension and mid-poison of forearm in sitting position. A pressure algometer was applied on hand extensor muscles to define their trigger point sensitivity. For the control group, treatment regimens consisted of routine physical therapy of tennis elbow. This regime was accompanied by dry needling of mentioned muscles for the intervention group. Wilcoxon and Mann-Whitney non-parametric tests were used for statistical analysis. Results: Comparison of the results after intervention showed that the patients’ pain significantly decreased in both groups (P<0.001; but the patient’s PPT and grip force significantly increased solely in the intervention group (P<0.05. Mann Whitney test showed significant pain differences in both groups (P=0.001. The comparison of differences

  19. Relationship among maximal grip, throwing velocity and anthropometric parameters in elite water polo players.

    Science.gov (United States)

    Ferragut, C; Vila, H; Abraldes, J A; Argudo, F; Rodriguez, N; Alcaraz, P E

    2011-03-01

    As independent aspects, body size, body composition, and physiological performance of elite athletes have aroused the interest of sports scientists but, unfortunately, studies that combine these aspects are scarcely avalaible in water polo. The aim of the present study was to: 1) to develop an anthropometric profile of highly skilled male Water Polo players, and 2) to identify significant relationships between these features and overhead throwing velocity in highly skilled male water polo players. Thirteen male water polo players, with a mean age of 26.10±4.82, were recruited from the Spanish Water Polo team and an anthropometric assessment on all of them was carried out. Throwing velocity was evaluated in three different situations from the 5 m-penalty line on the center of the water polo goal: A) throwing without a defender nor a goalkeeper; B) throwing with a goalkeeper only, and C) 3) armfuls running shot with goalkeeper. Maximal handgrip was also tested. Biacromial breadth shows a significative correlation with hand grip in water polo players (r=0.792; P=0.001) and also correlates with Throwing velocity (r=0.716; P<0.001). Biepicondylar femur breadth correlates significatively with hand grip (r=0.727; P<0.05) and also with throwing velocity in "throwing with goalkeeper" situation (r=0.664; P<0.05). Hand grip shows a significant correlation with throwing velocity in "throwing with goalkeeper" situation (r=0.603; P<0.05). In conclusion, body mass aspects are not related with throwing velocity in highly skilled Water Polo players. Maximal hand grip is related with throwing velocity in "throwing with goalkeeper" situation. More investigations about water polo are necessary.

  20. Quantitative Analysis of Lateral Pinch Force in Quadriplegic Patients Using Functional Neuromuscular Stimulation with Computer Stimulation

    Directory of Open Access Journals (Sweden)

    Ali Esteki

    2004-10-01

    Full Text Available Objective: In some applications of functional neuromuscular stimulation (FNS, the distal joint of the thumb (IP in quadriplegic patients is sometimes surgically fused at zero degrees and the FPL is stimulated. This prevents hyperextension and extreme flexion of the IP joint during lateral pinch. However, IP joint fusion removes one degree of freedom from the thumb and may reduce the grip force. An alternative approach, preferably without surgical alterations, using sufficient electrical stimulation of selected muscles was investigated. A 3D model of prehensile lateral pinch was developed. Computer simulation of the model was used to find an approach providing the appropriate posture and adequate lateral grip force for quadriplegic patients using FNS. Materials & Methods: The model consists of a multi-rigid-body system connected by one or two degree(s of freedom joints acted upon by passive resistive moments, active muscle moments and moments of external contact forces. Passive resistive moments were measured at each joint, active muscle moments were computed using a simple muscle model, and moments of external force were computed based on a force-displacement relationship for finger pads. In addition to the current strategy, two possible alternatives were studied: increasing the fused joint angle and activation of multiple muscles without joint fusion. Normal component of the grip force and its angle with respect to the horizontal plane were computed and compared for the studied cases. Results: Results showed, by using the current FNS strategy, a convenient posture and a grip force of 10.1 (N are achieved which is comparable to what is measured experimentally and introduced in the literature. Increasing the joint fusion angle from 0 to 15 and 30 degrees in parallel with the activation of FPL increased the grip force from 10.1 to 10.7 and 11.2 (N, respectively, but resulted in inconvenient posture. Among all different combinations of the muscles

  1. Improvement of handle grip using reverse engineering, CAE and Rapid Prototyping

    Directory of Open Access Journals (Sweden)

    Stoklasek Pavel

    2016-01-01

    Full Text Available The overwhelming majority of manual operations is even nowadays performed by using manual hand tools. These tools can be divided into 2 groups – hand tools designed for general use or a single-purpose hand tools for special operations. Tool described in this paper is used in assembling operation in the completion of electric motor. During the design of the existing tools the requirements for a functional part of the tool (lifespan, inability to damage the engine installation were fully considered, demands for ergonomic grip area, however, were not taken into account. Long-term use of incorrectly designed tool causes carpal tunnel syndrome, hand-arm vibration syndrome, diminished sensitivity or tingling in the fingers of workers. These difficulties can be reduced or entirely eliminated due to proper design of the grip of hand tool. Most authors focus on adjusting the grip for optimum ergonomics at individual types of grips (cylindrical, palmar, lateral, etc.. However, as already mentioned, there are tools for specific operations when the working area is limited by space or a specific type of load on the grip is needed. In some cases, it is often necessary to change the type of grip or combine different types of grips. This paper describes the design of an optimal grip of hand tool used for specific operation when assembling motors. Design of prototype mold and production of functional prototypes for ergonomics assessment directly in the workplace were realized. New design of handle should reduce the risk primarily of developing carpal tunnel in long-term use.

  2. Grip Analysis of Road Surface and Tire Footprint Using FEM

    Science.gov (United States)

    Sabri, M.; Abda, S.

    2018-02-01

    Road grip involve a touch between road pavement and the tire tread pattern. The load bearing surface, which depends on pavement roughness and local pressures in the contact patch. This research conducted to develop a Finite element model for simulating the experimentally testing of asphalt in Jl. AH Nasution Medan, North Sumatera Indonesia base on the value of grip coefficient from various tire loads and the various speed of the vehicle during contact to the road. A tire model and road pavement are developed for the analyses the geometry of tire footprint. The results showed that the greater the mass of car will increase grip coefficient. The coefficient of grip on the road surface contact trough the tire footprint strongly influence the kinetic coefficient of friction at certain speeds. Experimentally show that Concrete road grip coefficient of more than 34% compared to the asphalt road at the same IRI parameters (6-8). Kinetic friction coefficient more than 0.33 was obtained in a asphalt path at a speed of 30-40 Km/hour.

  3. Grip for sawing round timber

    Energy Technology Data Exchange (ETDEWEB)

    1982-07-01

    This paper describes a device development at Gedling Colliery, Nottinghamshire Area, United Kingdom. It is a gripping attachment, designed to overcome the safety hazards involved in cross cutting timbers with a circular saw.

  4. Tensile testing grips are easily assembled under liquid nitrogen

    Science.gov (United States)

    Skalka, R. J.; Vandergrift, E. F.

    1967-01-01

    Split-screw grips for tensile testing provide uniform loading on the specimen shoulders. Holes in the heads enable the screws and specimen to be threaded as an assembly into a grip body, closely controlled guides and seats afford positive seating, and precision machining of mating surfaces minimizes misalignment effects.

  5. Algorithm Design for Grip-Pattern Verification in Smart Gun

    NARCIS (Netherlands)

    Shang, X.; Veldhuis, Raymond N.J.; Bazen, A.M.; Ganzevoort, W.P.T.

    2005-01-01

    The Secure Grip project1 focuses on the development of a hand-grip pattern recognition system, as part of the smart gun. Its target customer is the police. To explore the authentication performance of this system, we collected data from a group of police officers, and made authentication simulations

  6. GRIP Database original data - GRIPDB | LSDB Archive [Life Science Database Archive metadata

    Lifescience Database Archive (English)

    Full Text Available switchLanguage; BLAST Search Image Search Home About Archive Update History Data List Contact us GRI...PDB GRIP Database original data Data detail Data name GRIP Database original data DOI 10....18908/lsdba.nbdc01665-006 Description of data contents GRIP Database original data It consists of data table...s and sequences. Data file File name: gripdb_original_data.zip File URL: ftp://ftp.biosciencedbc.jp/archive/gripdb/LATEST/gri...e Database Description Download License Update History of This Database Site Policy | Contact Us GRIP Database original data - GRIPDB | LSDB Archive ...

  7. The Effect of Isometric Massage on Global Grip Strength after Conservative Treatment of Distal Radial Fractures. Pilot Study.

    Science.gov (United States)

    Ratajczak, Karina; Płomiński, Janusz

    2015-01-01

    The most common fracture of the distal end of the radius is Colles' fracture. Treatment modalities available for use in hand rehabilitation after injury include massage. The aim of this study was to evaluate the effect of isometric massage on the recovery of hand function in patients with Colles fractures. For this purpose, the strength of the finger flexors was assessed as an objective criterion for the evaluation of hand function. The study involved 40 patients, randomly divided into Group A of 20 patients and Group B of 20 patients. All patients received physical therapy and exercised individually with a physiotherapist. Isometric massage was additionally used in Group A. Global grip strength was assessed using a pneumatic force meter on the first and last day of therapy. Statistical analysis was performed using STATISTICA. Statistical significance was defined as a P value of less than 0.05. In both groups, global grip strength increased significantly after the therapy. There was no statistically significant difference between the groups. The men and women in both groups equally improved grip strength. A statistically significant difference was demonstrated between younger and older patients, with younger patients achieving greater gains in global grip strength in both groups. The incorporation of isometric massage in the rehabilitation plan of patients after a distal radial fracture did not significantly contribute to faster recovery of hand function or improve their quality of life.

  8. Discrimination of handlebar grip samples by fourier transform infrared microspectroscopy analysis and statistics

    Directory of Open Access Journals (Sweden)

    Zeyu Lin

    2017-01-01

    Full Text Available In this paper, the authors presented a study on the discrimination of handlebar grip samples, to provide effective forensic science service for hit and run traffic cases. 50 bicycle handlebar grip samples, 49 electric bike handlebar grip samples, and 96 motorcycle handlebar grip samples have been randomly collected by the local police in Beijing (China. Fourier transform infrared microspectroscopy (FTIR was utilized as analytical technology. Then, target absorption selection, data pretreatment, and discrimination of linked samples and unlinked samples were chosen as three steps to improve the discrimination of FTIR spectrums collected from different handlebar grip samples. Principal component analysis and receiver operating characteristic curve were utilized to evaluate different data selection methods and different data pretreatment methods, respectively. It is possible to explore the evidential value of handlebar grip residue evidence through instrumental analysis and statistical treatments. It will provide a universal discrimination method for other forensic science samples as well.

  9. Wearable flex sensor system for multiple badminton player grip identification

    Science.gov (United States)

    Jacob, Alvin; Zakaria, Wan Nurshazwani Wan; Tomari, Mohd Razali Bin Md; Sek, Tee Kian; Suberi, Anis Azwani Muhd

    2017-09-01

    This paper focuses on the development of a wearable sensor system to identify the different types of badminton grip that is used by a player during training. Badminton movements and strokes are fast and dynamic, where most of the involved movement are difficult to identify with the naked eye. Also, the usage of high processing optometric motion capture system is expensive and causes computational burden. Therefore, this paper suggests the development of a sensorized glove using flex sensor to measure a badminton player's finger flexion angle. The proposed Hand Monitoring Module (HMM) is connected to a personal computer through Bluetooth to enable wireless data transmission. The usability and feasibility of the HMM to identify different grip types were examined through a series of experiments, where the system exhibited 70% detection ability for the five different grip type. The outcome plays a major role in training players to use the proper grips for a badminton stroke to achieve a more powerful and accurate stroke execution.

  10. Covalent bond force profile and cleavage in a single polymer chain

    Science.gov (United States)

    Garnier, Lionel; Gauthier-Manuel, Bernard; van der Vegte, Eric W.; Snijders, Jaap; Hadziioannou, Georges

    2000-08-01

    We present here the measurement of the single-polymer entropic elasticity and the single covalent bond force profile, probed with two types of atomic force microscopes (AFM) on a synthetic polymer molecule: polymethacrylic acid in water. The conventional AFM allowed us to distinguish two types of interactions present in this system when doing force spectroscopic measurements: the first interaction is associated with adsorption sites of the polymer chains onto a bare gold surface, the second interaction is directly correlated to the rupture process of a single covalent bond. All these bridging interactions allowed us to stretch the single polymer chain and to determine the various factors playing a role in the elasticity of these molecules. To obtain a closer insight into the bond rupture process, we moved to a force sensor stable in position when measuring attractive forces. By optimizing the polymer length so as to fulfill the elastic stability conditions, we were able for the first time to map out the entire force profile associated with the cleavage of a single covalent bond. Experimental data coupled with molecular quantum mechanical calculations strongly suggest that the breaking bond is located at one end of the polymer chain.

  11. Hand grip strength in patients with chronic obstructive pulmonary disease

    Directory of Open Access Journals (Sweden)

    Jeong M

    2017-08-01

    Full Text Available Moa Jeong,1 Hyung Koo Kang,1 Pamela Song,2 Hye Kyeong Park,1 Hoon Jung,1 Sung-Soon Lee,1 Hyeon-Kyoung Koo1 1Division of Pulmonary and Critical Care Medicine, Department of Internal Medicine, 2Department of Neurology, Ilsan Paik Hospital, Inje University College of Medicine, Goyang, Republic of Korea Purpose: Hand grip strength (HGS is a simple way of predicting the risk of cardiovascular disease and all-cause mortality in the general population. However, the practical significance of grip strength in patients with COPD is uncertain. The aim of this study was to compare HGS between subjects with and without COPD and to evaluate its clinical relevance in patients with COPD by using a national survey.Methods: Data were collected from the Korean National Health and Nutrition Examination Survey. The study included 421 adults with COPD and 2,542 controls who completed questionnaires, spirometry, and a HGS test. HGS was compared between subjects with and without COPD, and the association between grip strength, lung function, and quality of life (QoL was evaluated.Results: The mean HGS was 33.3±9.1 kg in the COPD group and 29.9±9.5 kg in the non-COPD group; adjusted HGS was 30.9±0.33 kg and 30.9±0.11 kg, respectively (P=0.99. HGS was not related to forced vital capacity (β=0.04, P=0.70 or forced expiratory volume in 1 second (β=0.11, P=0.24 in multivariable analysis. HGS was independently associated with the EQ-5D index, but the relationship was stronger in the COPD group (β=0.30, P<0.001 than in the non-COPD group (β=0.21, P<0.001. The results were similar for each component of the EQ-5D, including mobility (β=-0.25, P<0.001, daily activity (β=-0.19, P=0.01, pain/discomfort (β=-0.32, P<0.001, and anxiety/depression (β=-0.16, P=0.01.Conclusion: HGS was not different between subjects with and without COPD, but was associated with QoL – including mobility, daily activity, pain/discomfort, and anxiety/depression – in patients with COPD. The

  12. Attentional Focus and Grip Width Influences on Bench Press Resistance Training.

    Science.gov (United States)

    Calatayud, Joaquin; Vinstrup, Jonas; Jakobsen, Markus D; Sundstrup, Emil; Colado, JuanCarlos; Andersen, Lars L

    2018-04-01

    This study evaluated the influence of different attentional foci for varied grip widths in the bench press. Eighteen resistance-trained men were familiarized with the procedure and performed a one-repetition maximum (1RM) test during Session 1. In Session 2, they used three different standardized grip widths (100%, 150%, and 200% of biacromial width distance) in random order at 50% of 1RM while also engaged in three different attention focus conditions (external focus on the bench press, internal focus on pectoralis major muscles, and internal focus on triceps brachii muscles). Surface electromyography (EMG) signals were recorded from the triceps brachii and pectoralis major, and peak EMG of the filtered signals were normalized to maximum EMG of each muscle. Both grip width and focus influenced the muscle activity level, but there were no significant interactions between these variables. Exploratory analyses suggested that an internal focus may slightly (4%-6%) increase pectoralis major activity at wider grip widths and triceps brachii activity at narrower grip widths, but this should be confirmed or rejected in a study with a larger sample size or through a meta-analysis of research to date.

  13. Effects of transcranial direct current stimulation on the control of finger force during dexterous manipulation in healthy older adults.

    Directory of Open Access Journals (Sweden)

    Pranav J Parikh

    Full Text Available The contribution of poor finger force control to age-related decline in manual dexterity is above and beyond ubiquitous behavioral slowing. Altered control of the finger forces can impart unwanted torque on the object affecting its orientation, thus impairing manual performance. Anodal transcranial direct current stimulation (tDCS over primary motor cortex (M1 has been shown to improve the performance speed on manual tasks in older adults. However, the effects of anodal tDCS over M1 on the finger force control during object manipulation in older adults remain to be fully explored. Here we determined the effects of anodal tDCS over M1 on the control of grip force in older adults while they manipulated an object with an uncertain mechanical property. Eight healthy older adults were instructed to grip and lift an object whose contact surfaces were unexpectedly made more or less slippery across trials using acetate and sandpaper surfaces, respectively. Subjects performed this task before and after receiving anodal or sham tDCS over M1 on two separate sessions using a cross-over design. We found that older adults used significantly lower grip force following anodal tDCS compared to sham tDCS. Friction measured at the finger-object interface remained invariant after anodal and sham tDCS. These findings suggest that anodal tDCS over M1 improved the control of grip force during object manipulation in healthy older adults. Although the cortical networks for representing objects and manipulative actions are complex, the reduction in grip force following anodal tDCS over M1 might be due to a cortical excitation yielding improved processing of object-specific sensory information and its integration with the motor commands for production of manipulative forces. Our findings indicate that tDCS has a potential to improve the control of finger force during dexterous manipulation in older adults.

  14. Comparative study of millennials' (age 20-34 years) grip and lateral pinch with the norms.

    Science.gov (United States)

    Fain, Elizabeth; Weatherford, Cara

    Cross-sectional research design. Clinical practice continues to use normative data for grip and pinch measurements that were established in 1985. There is no updated norms despite different hand usage patterns in today's society. Measuring and comparing grip and pinch strengths with normative data is a valid method to determine hand function. This research was implemented to compare the grip and pinch measurements obtained from healthy millennials to the established norms and to describe hand usage patterns for millennials. Grip and lateral pinch measurements were obtained from a sample of 237 healthy millennials (ages 20-34 years). Strength scores were statistically lower that older normative data in all millennial grip strengths, with the exception of the women in the age group of 30-34 years. Specifically, this statistically significant trend was observed in all male grip strengths, as well as in women in the age group of 20-24 years (bilateral grip) and 25-29 years (right grip). However, the lateral pinch data reflected was similar to the older norms with variances of 0.5-1 kg. Current data reflect statistically significant differences from the norms for all male grip measurements, as well as for women in the age group of 20-24 years (bilateral grip) and 25-29 years (right grip). No statistical significance was observed in the independent-sample t tests for the lateral pinch in men of all age groups. Statistical significance was noted for lateral pinch for female age groups for the left hand (20-24 years) and for bilateral lateral pinches (30-34 years). IV. Copyright © 2016 Hanley & Belfus. Published by Elsevier Inc. All rights reserved.

  15. Grip strength as a frailty diagnostic component in geriatric inpatients

    Directory of Open Access Journals (Sweden)

    Dudzińska-Griszek J

    2017-07-01

    Full Text Available Joanna Dudzińska-Griszek, Karolina Szuster, Jan Szewieczek Department of Geriatrics, School of Health Sciences in Katowice, Medical University of Silesia, Katowice, Poland Background: Frailty has emerged as a key medical syndrome predictive of comorbidity, disability, institutionalization and death. As a component of the five frailty phenotype diagnostic criteria, patient grip strength deserves attention as a simple and objective measure of the frailty syndrome. The aim of this study was to assess conditions that influence grip strength in geriatric inpatients.Patients and methods: The study group consisted of 80 patients aged 78.6±7.0 years ( X ± SD, with 68.8% women, admitted to the Department of Geriatrics. A comprehensive geriatric assessment was complemented with assessment for the frailty phenotype as described by Fried et al for all patients in the study group. Functional assessment included Barthel Index of Activities of Daily Living (Barthel Index, Instrumental Activities of Daily Living Scale and Mini-Mental State Examination.Results: Three or more frailty criteria were positive in 32 patients (40%, while 56 subjects (70% fulfilled the frailty criterion of weakness (grip strength test. Multivariate linear regression analysis revealed that two independent measures showed positive association with grip strength – Mini-Mental State Examination score (β=0.239; P=0.001 and statin use (β=0.213; P=0.002 – and four independent measures were negatively associated with grip strength – female sex (β=–0.671; P<0.001, C-reactive protein (β=–0.253; P<0.001, prior myocardial infarction (β=–0.190; P=0.006 and use of an antidepressant (β=–0.163; P=0.018. Low physical activity was identified as the only independent qualitative frailty component associated with 2-year mortality in multivariate logistic regression analysis after adjustment for age and sex (odds ratio =6.000; 95% CI =1.357–26.536; P=0.018.Conclusion: Cognitive

  16. New approach to the suction force at the leading edge of a profile with zero thickness

    NARCIS (Netherlands)

    Sparenberg, JA; de Jager, EM

    2004-01-01

    This paper considers the suction force at the leading edge of a profile with zero thickness in an incompressible and inviscid fluid flow. The theory is linear, and the approach to the suction force is from the innerside of the profile. It is shown that the suction force can be considered as an

  17. Handling device with grips operated by a servo-motor

    International Nuclear Information System (INIS)

    Sgarbi, F.; Detriche, J.M.

    1990-01-01

    On grip jaws are set up a detection circuit which allows the rocking of the control system from a control system in position to a control system in clamping strain when an object is held, and then which allows to use them by turns in order to keep only their advantages. A larger light touch handling is obtained. The application of this grip is recommended to catch brittle objects (for handicapped persons by example) [fr

  18. Grip Strength and Its Relationship to Police Recruit Task Performance and Injury Risk: A Retrospective Cohort Study.

    Science.gov (United States)

    Orr, Robin; Pope, Rodney; Stierli, Michael; Hinton, Benjamin

    2017-08-21

    Suitable grip strength is a police occupational requirement. The aim of this study was to investigate the association between grip strength, task performance and injury risk in a police population. Retrospective data of police recruits (n = 169) who had undergone basic recruit training were provided, including handgrip strength results, occupational task performance measures (consisting of police task simulations [SIM], tactical options [TACOPS] and marksmanship assessments) and injury records. Left hand grip strength (41.91 ± 8.29 kg) measures showed a stronger correlation than right hand grip strength (42.15 ± 8.53 kg) with all outcome measures. Recruits whose grip strength scores were lower were significantly more susceptible to failing the TACOPS occupational task assessment than those with greater grip strength scores, with significant ( p ≤ 0.003) weak to moderate, positive correlations found between grip strength and TACOPS performance. A significant ( p performance, with those performing better in marksmanship having higher grip strength. Left hand grip strength was significantly associated with injury risk ( r = -0.181, p = 0.018) but right hand grip strength was not. A positive association exists between handgrip strength and police recruit task performance (notably TACOPS and marksmanship) with recruits who scored poorly on grip strength being at greatest risk of occupational assessment task failure.

  19. Longitudinal assessment of grip strength using bulb dynamometer in Duchenne Muscular Dystrophy

    Directory of Open Access Journals (Sweden)

    Tatiana M. Pizzato

    2014-07-01

    Full Text Available BACKGROUND: Grip strength is used to infer functional status in several pathological conditions, and the hand dynamometer has been used to estimate performance in other areas. However, this relationship is controversial in neuromuscular diseases and studies with the bulb dynamometer comparing healthy children and children with Duchenne Muscular Dystrophy (DMD are limited. OBJECTIVE: The evolution of grip strength and the magnitude of weakness were examined in boys with DMD compared to healthy boys. The functional data of the DMD boys were correlated with grip strength. METHOD: Grip strength was recorded in 18 ambulant boys with DMD (Duchenne Group, DG aged 4 to 13 years (mean 7.4±2.1 and 150 healthy volunteers (Control Group, CG age-matched using a bulb dynamometer (North Coast- NC70154. The follow-up of the DG was 6 to 33 months (3-12 sessions, and functional performance was verified using the Vignos scale. RESULTS: There was no difference between grip strength obtained by the dominant and non-dominant side for both groups. Grip strength increased in the CG with chronological age while the DG remained stable or decreased. The comparison between groups showed significant difference in grip strength, with CG values higher than DG values (confidence interval of 95%. In summary, there was an increment in the differences between the groups with increasing age. Participants with 24 months or more of follow-up showed a progression of weakness as well as maintained Vignos scores. CONCLUSIONS: The amplitude of weakness increased with age in the DG. The bulb dynamometer detected the progression of muscular weakness. Functional performance remained virtually unchanged in spite of the increase in weakness.

  20. Adaptation of manipulation skills in physical contact with the environment to reference force profiles

    DEFF Research Database (Denmark)

    Abu-Dakka, Fares J.; Nemec, Bojan; Jørgensen, Jimmy A.

    2015-01-01

    We propose a new methodology for learning and adaption of manipulation skills that involve physical contact with the environment. Pure position control is unsuitable for such tasks because even small errors in the desired trajectory can cause significant deviations from the desired forces...... and torques. The proposed algorithm takes a reference Cartesian trajectory and force/torque profile as input and adapts the movement so that the resulting forces and torques match the reference profiles. The learning algorithm is based on dynamic movement primitives and quaternion representation...

  1. Effects of hand grip exercise on shoulder joint internal rotation and external rotation peak torque.

    Science.gov (United States)

    Lee, Dong-Rour; Jong-Soon Kim, Laurentius

    2016-08-10

    The goal of this study is to analyze the effects of hand grip training on shoulder joint internal rotation (IR)/external rotation (ER) peak torque for healthy people. The research was conducted on 23 healthy adults in their 20 s-30 s who volunteered to participate in the experiment. Hand grip power test was performed on both hands of the research subjects before/after the test to study changes in hand grip power. Isokinetic machine was used to measure the concentric IRPT (internal rotation peak torque) and concentric ERPT (external rotation peak torque) at the velocity of 60°/sec, 90°/sec, and 180°/sec before/after the test. Hand grip training was performed daily on the subject's right hand only for four weeks according to exercise program. Finally, hand grip power of both hands and the maximum torque values of shoulder joint IR/ER were measured before/after the test and analyzed. There was a statistically significant difference in the hand grip power of the right hand, which was subject to hand grip training, after the experiment. Also, statistically significant difference for shoulder ERPT was found at 60°/sec. Hand grip training has a positive effect on shoulder joint IRPT/ERPT and therefore can help strengthen muscles around the shoulder without using weight on the shoulder. Consequently, hand grip training would help maintain strengthen the muscles around the shoulder in the early phase of rehabilitation process after shoulder surgery.

  2. Grip and Pinch Strength Norms for Michigan Workers

    Directory of Open Access Journals (Sweden)

    Joel M. Phillips M.S., OTRL

    2013-06-01

    Full Text Available The purpose of this study was to create a norm reference of current grip and pinch strength norms for working-age Michigan adults. This normative study included a convenience sample of 179 volunteers who were employees at car plants in South East Michigan or hospital sites in West Michigan. Participants’ ages ranged from between 20 and 62 years of age with a mean age of 49.15 years. There were 78 females (44% and 101 males (56%. Subjects were classified by gender and in the age categories of ages 20 to 49 years and ages 50-62 years. Grip and pinch strength norms were collected following the American Society of Hand Therapy protocol. The norms from these working adults were calculated with descriptive statistics for males and females in two age classifications: ages 20 to 49 and ages 50 to 62 years. Standard Errors (SE are better than the 1985 norms for both males and females ages 20 to 49 years. SEs are higher than the ages 20 to 49 years’ norms for the ages 50 to 62 years age categories in both males and females. These norms offer a point of comparison for clinicians to use for clients in Michigan who are ages 20 to 62 years and who have a goal to improve their grip strength. Clients’ grip and pinch strength could be compared to their age level or gender norms using the comparison for one standard deviation above, below, or at the means.

  3. Hand Grip Strength: age and gender stratified normative data in a population-based study

    Directory of Open Access Journals (Sweden)

    Taylor Anne W

    2011-04-01

    Full Text Available Abstract Background The North West Adelaide Health Study is a representative longitudinal cohort study of people originally aged 18 years and over. The aim of this study was to describe normative data for hand grip strength in a community-based Australian population. Secondary aims were to investigate the relationship between body mass index (BMI and hand grip strength, and to compare Australian data with international hand grip strength norms. Methods The sample was randomly selected and recruited by telephone interview. Overall, 3 206 (81% of those recruited participants returned to the clinic during the second stage (2004-2006 which specifically focused on the collection of information relating to musculoskeletal conditions. Results Following the exclusion of 435 participants who had hand pain and/or arthritis, 1366 men and 1312 women participants provided hand grip strength measurement. The study population was relatively young, with 41.5% under 40 years; and their mean BMI was 28.1 kg/m2 (SD 5.5. Higher hand grip strength was weakly related to higher BMI in adults under the age of 30 and over the age of 70, but inversely related to higher BMI between these ages. Australian norms from this sample had amongst the lowest of the hand grip strength of the internationally published norms, except those from underweight populations. Conclusions This population demonstrated higher BMI and lower grip strength in younger participants than much of the international published, population data. A complete exploration of the relationship between BMI and hand grip strength was not fully explored as there were very few participants with BMI in the underweight range. The age and gender grip strength values are lower in younger adults than those reported in international literature.

  4. Simple and Reliable Method to Estimate the Fingertip Static Coefficient of Friction in Precision Grip.

    Science.gov (United States)

    Barrea, Allan; Bulens, David Cordova; Lefevre, Philippe; Thonnard, Jean-Louis

    2016-01-01

    The static coefficient of friction (µ static ) plays an important role in dexterous object manipulation. Minimal normal force (i.e., grip force) needed to avoid dropping an object is determined by the tangential force at the fingertip-object contact and the frictional properties of the skin-object contact. Although frequently assumed to be constant for all levels of normal force (NF, the force normal to the contact), µ static actually varies nonlinearly with NF and increases at low NF levels. No method is currently available to measure the relationship between µ static and NF easily. Therefore, we propose a new method allowing the simple and reliable measurement of the fingertip µ static at different NF levels, as well as an algorithm for determining µ static from measured forces and torques. Our method is based on active, back-and-forth movements of a subject's finger on the surface of a fixed six-axis force and torque sensor. µ static is computed as the ratio of the tangential to the normal force at slip onset. A negative power law captures the relationship between µ static and NF. Our method allows the continuous estimation of µ static as a function of NF during dexterous manipulation, based on the relationship between µ static and NF measured before manipulation.

  5. GRIP LIGHTNING INSTRUMENT PACKAGE (LIP) V1

    Data.gov (United States)

    National Aeronautics and Space Administration — The GRIP Lightning Instrument Package (LIP) dataset was collected by the Lightning Instrument Package (LIP), which consists of 6 rotating vane type electric field...

  6. Improvements in or relating to gripping means for handling nuclear reactor fuel assemblies

    International Nuclear Information System (INIS)

    Batjukov, V.I.; Vjugov, O.N.; Fadeev, A.I.; Shkhian, T.G.

    1980-01-01

    A gripping means for handling fuel assemblies, the heads of which are internally recessed to receive gripping jaws, forms part of a reactor refuelling machine and is telescopically accommodated within a manipulator tube of the machine. A through hole is provided to allow cooling medium to be passed through the fuel assemblies to remove afterheat when the gripping means is used to transfer assemblies from a reactor core to spent fuel storage sockets. (author)

  7. Hold, grasp, clutch or grab: consumer grip choices during food container opening.

    Science.gov (United States)

    Rowson, J; Yoxall, A

    2011-07-01

    Society is ageing and sadly that ageing leads to a host of issues, not least a society in which the majority are likely to have some loss of strength and dexterity. This can lead to complications in undertaking everyday tasks such as using transport, bathing or even handling and opening food. Packaging has to provide a multitude of services; to protect and preserve the product, to provide information to the consumer and not least to allow access to the contents. This access to packaging--or 'openability'--has become a significant issue for designers and manufacturers with the change in demographics as described above. Understanding the choices consumers make in how they manipulate packaging can help designers produce packaging that is more able to meet the requirements of modern society. Studies previously undertaken by the authors showed that consumers did use different grips when opening packaging and that certain grips were theoretically more comfortable and stronger than others. This paper outlines a further study whereby consumers were asked to apply the most common grips to a specially designed torque measuring device. Details were taken about the consumers: age, gender, occupation, hand size, plus their preferred grip choice for packaging of this type. The study showed that typically women chose a grip that maximised their opportunity of opening the closure and that this grip choice was more limited than that available for men. This has implications for inclusive design of many everyday products. Copyright © 2010 Elsevier Ltd and The Ergonomics Society. All rights reserved.

  8. Optimization of Easy Atomic Force Microscope (ezAFM) Controls for Semiconductor Nanostructure Profiling

    Science.gov (United States)

    2017-09-01

    ARL-MR-0965 ● SEP 2017 US Army Research Laboratory Optimization of Easy Atomic Force Microscope (ezAFM) Controls for... Optimization of Easy Atomic Force Microscope (ezAFM) Controls for Semiconductor Nanostructure Profiling by Satwik Bisoi Science and...REPORT TYPE Memorandum Report 3. DATES COVERED (From - To) 2017 July 05–2017 August 18 4. TITLE AND SUBTITLE Optimization of Easy Atomic Force

  9. GRIP FLIGHT TRACKS AND ANIMATIONS V1

    Data.gov (United States)

    National Aeronautics and Space Administration — The GRIP Flight Tracks and Animations dataset includes both KML files and animation files. The KML files use Google Earth to show the flight tracks on a map. The...

  10. Effect of Putting Grip on Eye and Head Movements During the Golf Putting Stroke

    Directory of Open Access Journals (Sweden)

    George K. Hung

    2003-01-01

    Full Text Available The objective of this article is to determine the effect of three different putting grips (conventional, cross-hand, and one-handed on variations in eye and head movements during the putting stroke. Seven volunteer novice players, ranging in age from 21 to 22 years, participated in the study. During each experimental session, the subject stood on a specially designed platform covered with artificial turf and putted golf balls towards a standard golf hole. The three different types of grips were tested at two distances: 3 and 9 ft. For each condition, 20 putts were attempted. For each putt, data were recorded over a 3-s interval at a sampling rate of 100 Hz. Eye movements were recorded using a helmet-mounted eye movement monitor. Head rotation about an imaginary axis through the top of the head and its center-of-rotation was measured by means of a potentiometer mounted on a fixed frame and coupled to the helmet. Putter-head motion was measured using a linear array of infrared phototransistors embedded in the platform. The standard deviation (STD, relative to the initial level was calculated for eye and head movements over the duration of the putt (i.e., from the beginning of the backstroke, through the forward stroke, to impact. The averaged STD for the attempted putts was calculated for each subject. Then, the averaged STDs and other data for the seven subjects were statistically compared across the three grip conditions. The STD of eye movements were greater (p < 0.1 for conventional than cross-hand (9 ft and one-handed (3 and 9 ft grips. Also, the STD of head movements were greater (p < 0.1; 3 ft for conventional than cross-hand and one-handed grips. Vestibulo-ocular responses associated with head rotations could be observed in many 9 ft and some 3 ft putts. The duration of the putt was significantly longer (p < 0.05; 3 and 9 ft for the one-handed than conventional and cross-hand grips. Finally, performance, or percentage putts made, was

  11. GRIP BARBADOS/CAPE VERDE RADIOSONDE V1

    Data.gov (United States)

    National Aeronautics and Space Administration — The GRIP Barbados/Cape Verde radiosonde data set consists of generally two soundings per day (06Z and 12Z) launched from Barbados, and one sounding per day (12Z)...

  12. GRIP HURRICANE IMAGING RADIOMETER (HIRAD) V1

    Data.gov (United States)

    National Aeronautics and Space Administration — The GRIP Hurricane Imaging Radiometer (HIRAD) V1 dataset contains measurements of brightness temperature taken at 4, 5, 6 and 6.6 GHz, as well as MERRA 2 m wind...

  13. An electromyographic study of the effect of hand grip sizes on forearm muscle activity and golf performance.

    Science.gov (United States)

    Sorbie, Graeme G; Hunter, Henry H; Grace, Fergal M; Gu, Yaodong; Baker, Julien S; Ugbolue, Ukadike Chris

    2016-01-01

    The study describes the differences in surface electromyography (EMG) activity of two forearm muscles in the lead and trail arm at specific phases of the golf swing using a 7-iron with three different grip sizes among amateur and professional golfers. Fifteen right-handed male golfers performed five golf swings using golf clubs with three different grip sizes. Surface EMG was used to measure muscle activity of the extensor carpi radialis brevis (ECRB) and flexor digitorum superficialis (FDS) on both forearms. There were no significant differences in forearm muscle activity when using the three golf grips within the group of 15 golfers (p > 0.05). When using the undersize grip, club head speed significantly increased (p = 0.044). During the backswing and downswing phases, amateurs produced significantly greater forearm muscle activity with all three grip sizes (p < 0.05). In conclusion, forearm muscle activity is not affected by grip sizes. However, club head speed increases when using undersize grips.

  14. Reliability of the Bulb Dynamometer for Assessing Grip Strength

    Directory of Open Access Journals (Sweden)

    Colleen Maher

    2018-04-01

    Full Text Available Background: Hand function is an overall indicator of health and is often measured using grip strength. Handheld dynamometry is the most common method of measuring grip strength. The purpose of this study was to determine the inter-rater and test-retest reliability, the reliability of one trial versus three trials, and the preliminary norms for a young adult population using the Baseline® Pneumatic Squeeze Bulb Dynamometer (30 psi. Methods: This study used a one-group methodological design. One hundred and three healthy adults (30 males and 73 females were recruited. Six measurements were collected for each hand per participant. The data was analyzed using Intraclass Correlation Coefficients (ICC two-way effects model (2,2 and paired-samples t-tests. Results: The ICC for inter-rater reliability ranged from 0.955 to 0.977. Conclusion: The results of this study suggest that the bulb dynamometer is a reliable tool to measure grip strength and should be further explored for reliable and valid use in diverse populations and as an alternative to the Jamar dynamometer.

  15. The end-state comfort effect in bimanual grip selection.

    Science.gov (United States)

    Fischman, Mark G; Stodden, David F; Lehman, Davana M

    2003-03-01

    During a unimanual grip selection task in which people pick up a lightweight dowel and place one end against targets at variable heights, the choice of hand grip (overhand vs. underhand) typically depends on the perception of how comfortable the arm will be at the end of the movement: an end-state comfort effect. The two experiments reported here extend this work to bimanual tasks. In each experiment, 26 right-handed participants used their left and right hands to simultaneously pick up two wooden dowels and place either the right or left end against a series of 14 targets ranging from 14 to 210 cm above the floor. These tasks were performed in systematic ascending and descending orders in Experiment 1 and in random order in Expiment 2. Results were generally consistent with predictions of end-state comfort in that, for the extreme highest and lowest targets, participants tended to select opposite grips with each hand. Taken together, our findings are consistent with the concept of constraint hierarchies within a posture-based motion-planning model.

  16. Force Myography to Control Robotic Upper Extremity Prostheses: A Feasibility Study

    Directory of Open Access Journals (Sweden)

    Erina eCho

    2016-03-01

    Full Text Available Advancement in assistive technology has led to the commercial availability of multi-dexterous robotic prostheses for the upper extremity. The relatively low performance of the currently used techniques to detect the intention of the user to control such advanced robotic prostheses, however, limits their use. This article explores the use of force myography (FMG as a potential alternative to the well-established surface electro-myography (sEMG. Specifically, the use of FMG to control different grips of a commercially available robotic hand, Bebionic3, are investigated. Four male transradially amputated subjects participated in the study and a protocol was developed to assess the prediction accuracy of eleven grips. Different combinations of grips were examined ranging from six up to eleven grips. The results indicate that it is possible to classify six primary grips important in activities of daily living using FMG with an accuracy of above 70% in the residual limb. Additional strategies to increase classification accuracy, such as using the available modes on the Bebionic3, allowed results to improve up to 88.83% and 89.00% for opposed thumb and non-opposed thumb modes respectively.

  17. 16 CFR Figure 5 to Part 1512 - Typical Handbrake Actuator Showing Grip Dimension

    Science.gov (United States)

    2010-01-01

    ... 16 Commercial Practices 2 2010-01-01 2010-01-01 false Typical Handbrake Actuator Showing Grip Dimension 5 Figure 5 to Part 1512 Commercial Practices CONSUMER PRODUCT SAFETY COMMISSION FEDERAL HAZARDOUS... Actuator Showing Grip Dimension EC03OC91.072 ...

  18. A firm political grip on the market

    International Nuclear Information System (INIS)

    Bakken, Stein Arne

    2003-01-01

    In Norway, there is a strong political grip on the energy supply industry. The market is going to play a marginal role. The article deals with three scenarios for what the Norwegian energy supply might look like in 2005 as envisaged by a group of researchers in a comprehensive project carried out by ECON. The first scenario, ''The Market Place'', shows the development of the energy supply from regulation to a free market in the wake of the new Energy Act. According to this scenario, by 2005 the market should be well established as a form of control. The second scenario, ''The Norwegian Way'', shows the way of the energy supply from a free market to regulation. The third scenario is ''The Field of Force'' and shows how the energy supply develops into a strong energy industrial complex; this is the scenario that definitely has not come true. The most likely scenario to come true in ten years is probably a mixture of ''The Market Place'' and ''The Norwegian Way'' with an emphasis on the latter. The trend is clearly for increased political control

  19. GRIP LIDAR ATMOSPHERIC SENSING EXPERIMENT (LASE) V1

    Data.gov (United States)

    National Aeronautics and Space Administration — The GRIP Lidar Atmospheric Sensing Experiment (LASE) dataset was collected by NASA's Lidar Atmospheric Sensing Experiment (LASE) system, which is an airborne...

  20. The Effects of Counterforce Brace Size on the Wrist Range of Motility, Pain, Grip & Wrist Extension Sterngth in Normal Subjects and Patients with Tennis Elbow

    Directory of Open Access Journals (Sweden)

    Ali Asghar Jameh-Bozorgi

    2006-04-01

    Full Text Available Objective: Counter force brace is one of the most usefull treatments for lateral opicondylitis (Tennis elbow because it decreases grip pain and increases the power of grip, power of wrist extension and Wrist Range of Motility. The purpose of this quasi experimental (repeated measurementsstudy was to determine the effect of 3 counterforce brace sizes on the wrist R.O.M, grip and wrist extension strength and pain intensity in two groups of healthy subjects and patients with tennis elbow. Materials & Methods: 18 normal subjects & 18 patients with tennis elbow were selected simple conveniently and were tested with no brace and 3 size of counterforce (1,2 and 3 inches. The R.O.M , strength and pain intensity were measured by jamar goniometry and Nicholas MMT dynamometry & VAS, respectively. Results: 1 With all sizes there was a significant decrease of R.O.M on normal subjects but no significant difference in patients. 2 There was a significant decrease of grip strength with 1-inch brace in normal subjects but a significant increase of grip strength with 2 and 3-inch brace in patiens. 3 All sizes of brace caused significant decrease of extension strength in normal subjects but increase in patients. 4All size caused significant decrease of pain intensity that was more considerable in the case of 2 and 3 inch size. Conclusion: The results shows that the counterforce brace may be considered as an effective treatment for increasing strength and decreasing pain in patients with tennis elbow.

  1. Synchronising EDML and NorthGRIP ice cores using d18O of atmospheric oxygen (d18 Oatm) and CH4 measurements over MIS5 (80-123 kyr)

    DEFF Research Database (Denmark)

    Capron, E; Landais, A; Lemieux-Dudon, B

    2010-01-01

    Water isotope records from the EPICA Dronning Maud Land (EDML) and the NorthGRIP ice cores have revealed a one to one coupling between Antarctic Isotope Maxima (AIM) and Greenland Dansgaard-Oeschger (DO) events back to 50 kyr. In order to explore if this north-south coupling is persistent over...... Marine Isotopic Stage 5 (MIS 5). a common timescale must first be constructed. Here, we present new records of delta O-18 of O-2 (delta O-18(atm)) and methane (CH4) measured in the air trapped in ice from the EDML (68-147 kyr) and NorthGRIP (70-123 kyr) ice cores. We demonstrate that, through the period...... of interest, CH4 records alone are not sufficient to construct a common gas timescale between the two cores. Millennial-scale variations of delta O-18(atm) are evidenced over MIS 5 both on the Antarctic and Greenland ice cores and are coupled to CH4 profiles to synchronise the NorthGRIP and EDML records...

  2. The psychological coping, learning potential and career preferences profiles of operational force military candidates

    CSIR Research Space (South Africa)

    De Beer, M

    2017-01-01

    Full Text Available The aim of this study was to profile the psychological coping, learning potential and career-related interests of 251 candidates for operational force military selection for the South African National Defence Force (SANDF) – 26 of whom were...

  3. Effects of hyperthyroidism on hand grip strength and function.

    Science.gov (United States)

    Erkol İnal, Esra; Çarlı, Alparslan Bayram; Çanak, Sultan; Aksu, Oğuzhan; Köroğlu, Banu Kale; Savaş, Serpil

    2015-01-01

    Hyperthyroidism is a pathologic condition in which the body is exposed to excessive amounts of circulating thyroid hormones. Skeletal muscle is one of the major target organs of thyroid hormones. We evaluated hand grip strength and function in patients with overt hyperthyroidism. Fifty-one patients newly diagnosed with hyperthyroidism and 44 healthy controls participated in this study. Age, height, weight, and dominant hand of all participants were recorded. The diagnosis of hyperthyroidism was confirmed by clinical examination and laboratory tests. Hand grip strength was tested at the dominant hand with a Jamar hand dynamometer. The grooved pegboard test (PGT) was used to evaluate hand dexterity. The Duruöz Hand Index (DHI) was used to assess hand function. No significant differences were found in terms of clinical and demographic findings between the patients with hyperthyroidism and healthy controls (p > 0.05). Significant differences were found between the patients with hyperthyroidism and healthy controls regarding PGT and DHI scores (p Hyperthyroidism seemed to affect hand dexterity and function more than hand grip strength and seemed to be associated with reduced physical function more than muscle strength. This may also indicate that patients with hyperthyroidism should be evaluated by multidisplinary modalities.

  4. Reliable and Accurate Release of Micro-Sized Objects with a Gripper that Uses the Capillary-Force Method

    Directory of Open Access Journals (Sweden)

    Suzana Uran

    2017-06-01

    Full Text Available There have been recent developments in grippers that are based on capillary force and condensed water droplets. These are used for manipulating micro-sized objects. Recently, one-finger grippers have been produced that are able to reliably grip using the capillary force. To release objects, either the van der Waals, gravitational or inertial-forces method is used. This article presents methods for reliably gripping and releasing micro-objects using the capillary force. The moisture from the surrounding air is condensed into a thin layer of water on the contact surfaces of the objects. From the thin layer of water, a water meniscus between the micro-sized object, the gripper and the releasing surface is created. Consequently, the water meniscus between the object and the releasing surface produces a high enough capillary force to release the micro-sized object from the tip of the one-finger gripper. In this case, either polystyrene, glass beads with diameters between 5–60 µm, or irregularly shaped dust particles of similar sizes were used. 3D structures made up of micro-sized objects could be constructed using this method. This method is reliable for releasing during assembly and also for gripping, when the objects are removed from the top of the 3D structure—the so-called “disassembling gripping” process. The accuracy of the release was lower than 0.5 µm.

  5. Identification of dynapenia in older adults through the use of grip strength t-scores.

    Science.gov (United States)

    Bohannon, Richard W; Magasi, Susan

    2015-01-01

    The aim of this study was to generate reference values and t-scores (1.0-2.5 standard deviations below average) for grip strength for healthy young adults and to examine the utility of t-scores from this group for the identification of dynapenia in older adults. Our investigation was a population-based, general community secondary analysis of cross-sectional grip strength data utilizing the NIH Toolbox Assessment norming sample. Participants consisted of community-dwelling adults, with age ranges of 20-40 years (n = 558) and 60-85 years (n = 390). The main outcome measure was grip strength using a Jamar plus dynamometer. Maximum grip strengths were consistent over the 20-40-year age group [men 108.0 (SD 22.6) pounds, women 65.8 (SD 14.6) pounds]. Comparison of older group grip strengths to those of the younger reference group revealed (depending on age strata) that 46.2-87.1% of older men and 50.0-82.4% of older women could be designated as dynapenic on the basis of t-scores. The use of reference value t-scores from younger adults is a promising method for determining dynapenia in older adults. © 2014 Wiley Periodicals, Inc.

  6. GRIP DOPPLER AEROSOL WIND LIDAR (DAWN) V1

    Data.gov (United States)

    National Aeronautics and Space Administration — The GRIP Doppler Aerosol WiNd Lidar (DAWN) Dataset was collected by the Doppler Aerosol WiNd (DAWN), a pulsed lidar, which operated aboard a NASA DC-8 aircraft...

  7. Grip strength in mice with joint inflammation: A rheumatology function test sensitive to pain and analgesia.

    Science.gov (United States)

    Montilla-García, Ángeles; Tejada, Miguel Á; Perazzoli, Gloria; Entrena, José M; Portillo-Salido, Enrique; Fernández-Segura, Eduardo; Cañizares, Francisco J; Cobos, Enrique J

    2017-10-01

    Grip strength deficit is a measure of pain-induced functional disability in rheumatic disease. We tested whether this parameter and tactile allodynia, the standard pain measure in preclinical studies, show parallels in their response to analgesics and basic mechanisms. Mice with periarticular injections of complete Freund's adjuvant (CFA) in the ankles showed periarticular immune infiltration and synovial membrane alterations, together with pronounced grip strength deficits and tactile allodynia measured with von Frey hairs. However, inflammation-induced tactile allodynia lasted longer than grip strength alterations, and therefore did not drive the functional deficits. Oral administration of the opioid drugs oxycodone (1-8 mg/kg) and tramadol (10-80 mg/kg) induced a better recovery of grip strength than acetaminophen (40-320 mg/kg) or the nonsteroidal antiinflammatory drugs ibuprofen (10-80 mg/kg) or celecoxib (40-160 mg/kg); these results are consistent with their analgesic efficacy in humans. Functional impairment was generally a more sensitive indicator of drug-induced analgesia than tactile allodynia, as drug doses that attenuated grip strength deficits showed little or no effect on von Frey thresholds. Finally, ruthenium red (a nonselective TRP antagonist) or the in vivo ablation of TRPV1-expressing neurons with resiniferatoxin abolished tactile allodynia without altering grip strength deficits, indicating that the neurobiology of tactile allodynia and grip strength deficits differ. In conclusion, grip strength deficits are due to a distinct type of pain that reflects an important aspect of the human pain experience, and therefore merits further exploration in preclinical studies to improve the translation of new analgesics from bench to bedside. Copyright © 2017 The Authors. Published by Elsevier Ltd.. All rights reserved.

  8. Enter the Gripping Beast

    DEFF Research Database (Denmark)

    Sindbæk, Søren Michael

    2012-01-01

    on innovations. Mostly, however, the time-resolution of archaeological data is too coarse-grained to allow us to grasp this potential to the full. In the period c. AD 790-850 a distinctly new artistic motif, the Gripping Beast, emerged in Scandinavia. A series of narrowly dated contexts provide anchor points......, which allows us to chart this innovation process and to point out some of the locations where this development took place; the reception of the mew motif is traced in grave finds across Scandinavia. This allows us to follow an early medieval innovation through the human-material interactions of an actor-network....

  9. Force feedback delay affects perception of stiffness but not action, and the effect depends on the hand used but not on the handedness.

    Science.gov (United States)

    Leib, Raz; Rubin, Inbar; Nisky, Ilana

    2018-05-16

    Interaction with an object often requires the estimation of its mechanical properties. We examined whether the hand that is used to interact with the object and their handedness affected people's estimation of these properties using stiffness estimation as a test case. We recorded participants' responses on a stiffness discrimination of a virtual elastic force field and the grip force applied on the robotic device during the interaction. In half of the trials, the robotic device delayed the participants' force feedback. Consistent with previous studies, delayed force feedback biased the perceived stiffness of the force field. Interestingly, in both left-handed and right-handed participants, for the delayed force field, there was even less perceived stiffness when participants used their left hand than their right hand. This result supports the idea that haptic processing is affected by laterality in the brain, not by handedness. Consistent with previous studies, participants adjusted their applied grip force according to the correct size and timing of the load force regardless of the hand that was used, the handedness, or the delay. This suggests that in all these conditions, participants were able to form an accurate internal representation of the anticipated trajectory of the load force (size and timing) and that this representation was used for accurate control of grip force independently of the perceptual bias. Thus, these results provide additional evidence for the dissociation between action and perception in the processing of delayed information.

  10. Association between grip strength and hand and knee radiographic osteoarthritis in Korean adults: Data from the Dong-gu study.

    Directory of Open Access Journals (Sweden)

    Lihui Wen

    Full Text Available We assessed whether grip strength was related to various types of radiographic damage in Korean adults with osteoarthritis (OA.Data from 2,251 subjects enrolled in the Dong-gu study, who had no hand joint pain, were analyzed to investigate the relationship between grip strength and OA. Hand grip strength was measured using a hand-held dynamometer, and radiographs of the hand and knee were scored according to a semi-quantitative grading system. Multiple linear regressions were used to explore associations between grip strength and radiographic features of OA.Grip strength in men and women was negatively related to hand (both p < 0.001 and knee (men, p < 0.001; women, p = 0.010 OA after adjusting for confounders. Hand (men, p < 0.001; women, p = 0.001 and knee (both p < 0.001 joint space narrowing (JSN showed the strongest associations with low grip strength, regardless of gender. Moreover, the severity of hand osteophytes in women (p = 0.001, and subchondral cysts (men, p < 0.001 was correlated with low grip strength in both genders.Among subjects without hand joint pain, low grip strength was associated significantly with hand and knee radiographic OA, regardless of gender. Among all types of OA radiographic damage, low grip strength showed the strongest association with JSN.

  11. Ulnar digits contribution to grip strength in patients with thumb carpometacarpal osteoarthritis is less than in normal controls.

    Science.gov (United States)

    Villafañe, Jorge H; Valdes, Kristin; Angulo-Diaz-Parreño, Santiago; Pillastrini, Paolo; Negrini, Stefano

    2015-06-01

    Grip testing is commonly used as an objective measure of strength in the hand and upper extremity and is frequently used clinically as a proxy measure of function. Increasing knowledge of hand biomechanics, muscle strength, and prehension patterns can provide us with a better understanding of the functional capabilities of the hand. The objectives of this study were to determine the contribution of ulnar digits to overall grip strength in individuals with thumb carpometacarpal (CMC) osteoarthritis (OA). Thirty-seven subjects participated in the study. This group consisted of 19 patients with CMC OA (aged 60-88 years) and 18 healthy subjects (60-88 years). Three hand configurations were used by the subjects during grip testing: use of the entire hand (index, middle, ring, and little fingers) (IMRL); use of the index, middle, and ring fingers (IMR); and use of only the index and middle fingers (IM). Grip strength findings for the two groups found that compared to their healthy counterparts, CMC OA patients had, on average, a strength deficiency of 45.6, 35.5, and 28.8 % in IMRL, IMR, and IM, respectively. The small finger contribution to grip is 14.3 % and the ring and small finger contribute 34 % in subjects with CMC OA. Grip strength decreases as the number of digits contributing decreased in both groups. The ulnar digits contribution to grip strength is greater than one third of total grip strength in subjects with CMC OA. Individuals with CMC OA demonstrate significantly decreased grip strength when compared to their healthy counterparts.

  12. Dynamical Coordination of Hand Intrinsic Muscles for Precision Grip in Diabetes Mellitus.

    Science.gov (United States)

    Li, Ke; Wei, Na; Cheng, Mei; Hou, Xingguo; Song, Jun

    2018-03-12

    This study investigated the effects of diabetes mellitus (DM) on dynamical coordination of hand intrinsic muscles during precision grip. Precision grip was tested using a custom designed apparatus with stable and unstable loads, during which the surface electromyographic (sEMG) signals of the abductor pollicis brevis (APB) and first dorsal interosseous (FDI) were recorded simultaneously. Recurrence quantification analysis (RQA) was applied to quantify the dynamical structure of sEMG signals of the APB and FDI; and cross recurrence quantification analysis (CRQA) was used to assess the intermuscular coupling between the two intrinsic muscles. This study revealed that the DM altered the dynamical structure of muscle activation for the FDI and the dynamical intermuscular coordination between the APB and FDI during precision grip. A reinforced feedforward mechanism that compensates the loss of sensory feedbacks in DM may be responsible for the stronger intermuscular coupling between the APB and FDI muscles. Sensory deficits in DM remarkably decreased the capacity of online motor adjustment based on sensory feedback, rendering a lower adaptability to the uncertainty of environment. This study shed light on inherent dynamical properties underlying the intrinsic muscle activation and intermuscular coordination for precision grip and the effects of DM on hand sensorimotor function.

  13. Integrated dynamic and static tactile sensor: focus on static force sensing

    Science.gov (United States)

    Wettels, Nicholas; Pletner, Baruch

    2012-04-01

    Object grasping by robotic hands in unstructured environments demands a sensor that is durable, compliant, and responsive to static and dynamic force conditions. In order for a tactile sensor to be useful for grasp control in these, it should have the following properties: tri-axial force sensing (two shear plus normal component), dynamic event sensing across slip frequencies, compliant surface for grip, wide dynamic range (depending on application), insensitivity to environmental conditions, ability to withstand abuse and good sensing behavior (e.g. low hysteresis, high repeatability). These features can be combined in a novel multimodal tactile sensor. This sensor combines commercial-off-the-shelf MEMS technology with two proprietary force sensors: a high bandwidth device based on PZT technology and low bandwidth device based on elastomers and optics. In this study, we focus on the latter transduction mechanism and the proposed architecture of the completed device. In this study, an embedded LED was utilized to produce a constant light source throughout a layer of silicon rubber which covered a plastic mandrel containing a set of sensitive phototransistors. Features about the contacted object such as center of pressure and force vectors can be extracted from the information in the changing patterns of light. The voltage versus force relationship obtained with this molded humanlike finger had a wide dynamic range that coincided with forces relevant for most human grip tasks.

  14. Ancient death-grip leaf scars reveal ant–fungal parasitism

    Science.gov (United States)

    Hughes, David P.; Wappler, Torsten; Labandeira, Conrad C.

    2011-01-01

    Parasites commonly manipulate host behaviour, and among the most dramatic examples are diverse fungi that cause insects to die attached to leaves. This death-grip behaviour functions to place insects in an ideal location for spore dispersal from a dead body following host death. Fossil leaves record many aspects of insect behaviour (feeding, galls, leaf mining) but to date there are no known examples of behavioural manipulation. Here, we document, to our knowledge, the first example of the stereotypical death grip from 48 Ma leaves of Messel, Germany, indicating the antiquity of this behaviour. As well as probably being the first example of behavioural manipulation in the fossil record, these data support a biogeographical parallelism between mid Eocene northern Europe and recent southeast Asia. PMID:20719770

  15. Ancient death-grip leaf scars reveal ant-fungal parasitism.

    Science.gov (United States)

    Hughes, David P; Wappler, Torsten; Labandeira, Conrad C

    2011-02-23

    Parasites commonly manipulate host behaviour, and among the most dramatic examples are diverse fungi that cause insects to die attached to leaves. This death-grip behaviour functions to place insects in an ideal location for spore dispersal from a dead body following host death. Fossil leaves record many aspects of insect behaviour (feeding, galls, leaf mining) but to date there are no known examples of behavioural manipulation. Here, we document, to our knowledge, the first example of the stereotypical death grip from 48 Ma leaves of Messel, Germany, indicating the antiquity of this behaviour. As well as probably being the first example of behavioural manipulation in the fossil record, these data support a biogeographical parallelism between mid Eocene northern Europe and recent southeast Asia.

  16. Getting a grip on affordances, attention and visual fields

    OpenAIRE

    Linden, Lotje van der; Theeuwes, Jan; Ellis, Rob

    2013-01-01

    van der Linden, L., Theeuwes, J., & Ellis, R. (2012). Getting a grip on affordances, attention, and visual fields. Poster presented at the 2012 William James Graduate School Symposium, Amsterdam, The Netherlands.

  17. Force-directed design of a voluntary closing hand prosthesis

    NARCIS (Netherlands)

    De Visser, H.; Herder, J.L.

    2000-01-01

    This paper presents the design of a body-powered voluntary closing prosthetic hand. It is argued that the movement of the fingers before establishing a grip is much less relevant for good control of the object held than the distribution of forces once the object has been contacted. Based on this

  18. GRIP DC-8 NAVIGATION AND HOUSEKEEPING DATA V1

    Data.gov (United States)

    National Aeronautics and Space Administration — This dataset contains aircraft navigational data obtained during the GRIP campaign (15 Aug 2010 - 30 Sep 2010). The NASA DC-8 is outfitted with a navigational...

  19. Predicting hand function in older adults: evaluations of grip strength, arm curl strength, and manual dexterity.

    Science.gov (United States)

    Liu, Chiung-Ju; Marie, Deana; Fredrick, Aaron; Bertram, Jessica; Utley, Kristen; Fess, Elaine Ewing

    2017-08-01

    Hand function is critical for independence in activities of daily living for older adults. The purpose of this study was to examine how grip strength, arm curl strength, and manual dexterous coordination contributed to time-based versus self-report assessment of hand function in community-dwelling older adults. Adults aged ≥60 years without low vision or neurological disorders were recruited. Purdue Pegboard Test, Jamar hand dynamometer, 30-second arm curl test, Jebsen-Taylor Hand Function Test, and the Late-Life Function and Disability Instrument were administered to assess manual dexterous coordination, grip strength, arm curl strength, time-based hand function, and self-report of hand function, respectively. Eighty-four adults (mean age = 72 years) completed the study. Hierarchical multiple regressions show that older adults with better arm curl strength (β = -.25, p function test. In comparison, older adults with better grip strength (β = .40, p function. The relationship between grip strength and hand function may be test-specific. Grip strength becomes a significant factor when the test requires grip strength to successfully complete the test tasks. Arm curl strength independently contributed to hand function in both time-based and self-report assessments, indicating that strength of extrinsic muscles of the hand are essential for hand function.

  20. Nutritional status is the major factor affecting grip strength of African HIV patients before and during antiretroviral treatment.

    Science.gov (United States)

    Filteau, S; PrayGod, G; Woodd, S L; Friis, H; Heimburger, D C; Koethe, J R; Kelly, P; Kasonka, L; Rehman, A M

    2017-10-01

    Low grip strength is a marker of frailty and a risk factor for mortality among HIV patients and other populations. We investigated factors associated with grip strength in malnourished HIV patients at referral to ART, and at 12 weeks and 2-3 years after starting ART. The study involved HIV-infected Zambian and Tanzanian participants recruited to the NUSTART trial when malnourished (body mass index <18.5 kg/m 2 ) and requiring ART. The relationship of grip strength to nutritional, infectious and demographic factors was assessed by multivariable linear regression at referral for ART (n = 1742) and after 12 weeks (n = 778) and 2-3 years of ART (n = 273). In analyses controlled only for sex, age and height, most nutrition and infection-related variables were associated with grip strength. However, in multivariable analyses, consistent associations were seen for fat-free mass index, mid-upper arm circumference, haemoglobin and systolic blood pressure, and a variable association with fat mass index in men. C-reactive protein and CD4 count had limited independent effects on grip strength, while receiving tuberculosis treatment was associated with weaker grip strength. In this population of originally malnourished HIV patients, poor grip strength was more strongly and independently associated with nutritional than with infection and inflammation variables. Programmes to improve health and survival of HIV patients should incorporate nutritional assessment and management and could use grip strength as a functional indicator of improving nutrition. © 2017 John Wiley & Sons Ltd.

  1. Anticipating different grips reduces bimanual end-state comfort: A tradeoff between goal-related and means-related planning processes.

    Directory of Open Access Journals (Sweden)

    Christian Seegelke

    Full Text Available The present study explored the sensitivity towards bimanual end-state comfort in a task that required anticipating different final grips. Participants simultaneously reached and grasped two objects with either a whole-hand grip (WHG or a precision grip (PG, and placed them at two target locations by transporting them either over or under an obstacle. The transport path was varied such that it could be either congruent (i.e., both objects over or under or incongruent (i.e., one object over and the other object under. In the congruent conditions, participants satisfied bimanual end-state comfort (and identical initial grips on the majority of trials. That is, participants adopted a PG for either hand when the objects were transported over the obstacle and a WHG for either hand when the objects were transported under the obstacle. In contrast, in the incongruent conditions, bimanual end-state comfort was significantly reduced, indicating the presence of intermanual inference. The results indicate that goal-related planning constraints (i.e., bimanual end-state comfort do not strictly take precedence over means-related constraints (i.e., identical initial grips if this requires anticipating different final grips. Thus, bimanual end-state comfort per se does not provide a predominant constraint in action selection, by which sensorimotor interference can be reduced. In line with the proposal that bimanual grip planning relies on a flexible constraint hierarchy, a simple formal model that considers bimanual grip posture planning as a tradeoff between goal-related and means-related planning processes can explain our results reasonably well.

  2. Grip strength measurements at two different wrist extension positions in chronic lateral epicondylitis-comparison of involved vs. uninvolved side in athletes and non athletes: a case-control study

    Directory of Open Access Journals (Sweden)

    Bhargava Arti S

    2010-09-01

    Full Text Available Abstract Background Lateral epicondylitis is a common sports injury of the elbow caused due to altered muscle activation during repetitive wrist extension in many athletic and non-athletic endeavours. The amount of muscle activity and timing of contraction eventually is directly dependent upon joint position during the activity. The purpose of our study was to compare the grip strength in athletes with lateral epicondylalgia in two different wrist extension positions and compare them between involved and uninvolved sides of athletes and non-athletes. Methods An assessor-blinded case-control study of eight athletes and twenty-two non-athletes was done. The grip strength was measured using JAMAR® hand dynamometer in kilograms-force at 15 degrees (slightly extended and 35 degrees (moderately extended wrist extension positions (maintained by wrist splints on both involved and uninvolved sides of athletes and non-athletes with unilateral lateral epicondylitis of atleast 3 months duration. Their pain was to be elicited with local tenderness and two of three tests being positive- Cozen's, Mill's manoeuvre, resisted middle finger extension tests. For comparisons of grip strength, Wilcoxon signed rank test was used for within-group comparison (between 15 and 35 degrees wrist extension positions and Mann-Whitney U test was used for between-group (athletes vs. non-athletes comparisons at 95% confidence interval and were done using SPSS 11.5 for Windows. Results Statistically significant greater grip strength was found in 15 degrees (27.75 ± 4.2 kgms in athletes; 16.45 ± 4.2 kgms in non-athletes wrist extension than at 35 degrees (25.25 ± 3.53 kgm in athletes and 14.18 ± 3.53 kgm in non-athletes. The athletes had greater grip strength than non-athletes in each of test positions (11.3 kgm at 15 degrees and 11.07 kgm at 35 degrees measured. There was also a significant difference between involved and uninvolved sides' grip strength at both wrist

  3. GRIP: A web-based system for constructing Gold Standard datasets for protein-protein interaction prediction

    Directory of Open Access Journals (Sweden)

    Zheng Huiru

    2009-01-01

    Full Text Available Abstract Background Information about protein interaction networks is fundamental to understanding protein function and cellular processes. Interaction patterns among proteins can suggest new drug targets and aid in the design of new therapeutic interventions. Efforts have been made to map interactions on a proteomic-wide scale using both experimental and computational techniques. Reference datasets that contain known interacting proteins (positive cases and non-interacting proteins (negative cases are essential to support computational prediction and validation of protein-protein interactions. Information on known interacting and non interacting proteins are usually stored within databases. Extraction of these data can be both complex and time consuming. Although, the automatic construction of reference datasets for classification is a useful resource for researchers no public resource currently exists to perform this task. Results GRIP (Gold Reference dataset constructor from Information on Protein complexes is a web-based system that provides researchers with the functionality to create reference datasets for protein-protein interaction prediction in Saccharomyces cerevisiae. Both positive and negative cases for a reference dataset can be extracted, organised and downloaded by the user. GRIP also provides an upload facility whereby users can submit proteins to determine protein complex membership. A search facility is provided where a user can search for protein complex information in Saccharomyces cerevisiae. Conclusion GRIP is developed to retrieve information on protein complex, cellular localisation, and physical and genetic interactions in Saccharomyces cerevisiae. Manual construction of reference datasets can be a time consuming process requiring programming knowledge. GRIP simplifies and speeds up this process by allowing users to automatically construct reference datasets. GRIP is free to access at http://rosalind.infj.ulst.ac.uk/GRIP/.

  4. The development of a methodology to determine the relationship in grip size and pressure to racket head speed in a tennis forehand stroke

    DEFF Research Database (Denmark)

    Christensen, Jonas; Rasmussen, John; Halkon, Ben

    2016-01-01

    and kinematic contribution of the body segments in the upper trunk translational and angular velocities. Two Babolat Pure Storm GT rackets, with grip sizes 2 and 4 respectively, were used with Tekscan 9811E pressure sensors applied to the handles to examine pressure distribution during the stroke. Upper body...... kinematic data taken from the racket arm and trunk were obtained by means of a Vicon motion capture system. One elite male tennis player was recruited. Fifty topspin forehand strokes per grip at two nominal grip pressures were performed in a laboratory environment with balls being tossed towards the player...... joint and wrist joint in KCAV across grip conditions. Grip pressure for grip size 2 showed the same pattern across gripping conditions. From 50-75% of completion in forward swing, the pressure difference due to grip firmness decreased. This feasibility study managed to quantify the KCAV while performing...

  5. Validity of a Simple Method for Measuring Force-Velocity-Power Profile in Countermovement Jump.

    Science.gov (United States)

    Jiménez-Reyes, Pedro; Samozino, Pierre; Pareja-Blanco, Fernando; Conceição, Filipe; Cuadrado-Peñafiel, Víctor; González-Badillo, Juan José; Morin, Jean-Benoît

    2017-01-01

    To analyze the reliability and validity of a simple computation method to evaluate force (F), velocity (v), and power (P) output during a countermovement jump (CMJ) suitable for use in field conditions and to verify the validity of this computation method to compute the CMJ force-velocity (F-v) profile (including unloaded and loaded jumps) in trained athletes. Sixteen high-level male sprinters and jumpers performed maximal CMJs under 6 different load conditions (0-87 kg). A force plate sampling at 1000 Hz was used to record vertical ground-reaction force and derive vertical-displacement data during CMJ trials. For each condition, mean F, v, and P of the push-off phase were determined from both force-plate data (reference method) and simple computation measures based on body mass, jump height (from flight time), and push-off distance and used to establish the linear F-v relationship for each individual. Mean absolute bias values were 0.9% (± 1.6%), 4.7% (± 6.2%), 3.7% (± 4.8%), and 5% (± 6.8%) for F, v, P, and slope of the F-v relationship (S Fv ), respectively. Both methods showed high correlations for F-v-profile-related variables (r = .985-.991). Finally, all variables computed from the simple method showed high reliability, with ICC >.980 and CV push-off distance, and jump height are known.

  6. Grip strength is not associated with incident type 2 diabetes mellitus in healthy adults: The CoLaus study.

    Science.gov (United States)

    Marques-Vidal, Pedro; Vollenweider, Peter; Waeber, Gérard; Jornayvaz, François R

    2017-10-01

    We examined the association of grip strength with incident type 2 diabetes mellitus (T2DM) in healthy subjects initially aged 50 to 75years after a follow-up of 5.5years and 10.7years. This was a prospective, population-based study derived from the CoLaus (Cohorte Lausannoise) study including 2318 participants (aged 60.2y; 1354 women) free from T2DM at baseline. Grip strength was assessed using a handheld dynamometer. The effect of grip strength on the incidence of T2DM was analyzed by logistic regression. After a follow-up of 5.5years, 190 (8.2%) T2DM cases were identified. In bivariate analysis, participants who developed T2DM had a higher absolute grip strength (35.3±10.6 versus 33.2±10.7kg, P=0.013). Analysis between grip strength expressed in 5kg increment and incident TD2M showed a negative association when adjusted for age and sex [ORs (95% CI): 0.88 (0.79, 0.98)], or for age, sex and body mass index (BMI) [ORs (95% CI): 0.87 (0.78, 097)]. After a follow-up of 10.7years, 131 supplemental (7.3%) T2DM cases were identified, but there was no association between grip strength and incident T2DM in bivariate and multivariable analysis, potentially due to a lack of statistical power. In non elderly healthy adults, the risk of incident T2DM is overall not associated with grip strength over a maximum follow-up of 10.7years. Future studies are warranted to better assess the association between grip strength and incident T2DM in bigger and even younger cohorts. Copyright © 2017 Elsevier B.V. All rights reserved.

  7. Efeito da preensão manual sobre o equilíbrio de judocas Effect of hand grip on the balance of judokas

    Directory of Open Access Journals (Sweden)

    Jonathan Ache Dias

    2011-06-01

    Full Text Available O objetivo deste estudo foi verificar se existe efeito da preensão manual máxima (o ato de realizar ou não a preensão sobre o controle do equilíbrio de judocas em postura restrita, além de verificar se existe correlação entre a força de preensão manual (FPM e o controle do equilíbrio. Foram avaliados sete judocas com um dinamômetro e uma plataforma estabilométrica sendo mensuradas, concomitantemente, a FPM e o centro de pressão (CP. Foi verificado que até 80% da variabilidade do CP pode ser atrelada a preensão manual indicando que a mesma gera perturbações no controle do equilíbrio. Entretanto, foram encontradas correlações (r = 0,348 até 0,816 entre a FPM e o deslocamento do CP. Com isso pode-se concluir que, apesar da preensão manual gerar perturbações no equilíbrio, seu comportamento parece estar relacionado com os movimentos do corpo realizados para manter o equilíbrio, indicando uma possível correlação entre esses fenômenos.The purpose of this study was to verify if there is an effect of maximum hand grip (the act of performing or not the hand grip on the balance control of judokas in a restrict posture, and also to verify if there is a correlation between the hand grip strength (HGS and the balance control. Seven judokas were evaluated with a dynamometer and a stabilometric force platform, being measured, at the same time, the HGS and the center of pressure (COP. It was found that up to 80% of the COP variability was related to the hand grip demonstrating that it generates perturbations to the balance control. However, It was found correlations (r = 0,348 to 0,816 between de HGS and de COP displacement. With that, it can be concluded that, despite the hand grip generating perturbation on the balance, its behavior appears to be related to the body movements performed to sustain balance, indicating a possible correlation between this phenomenons.

  8. Direct observation of salts as micro-inclusions in the Greenland GRIP ice core

    DEFF Research Database (Denmark)

    Dahl-Jensen, Dorthe; Sakurai, Toshimitsu; Iizuka, Yoshinori

    2009-01-01

    We provide the first direct evidence that a number of water-soluble compounds, in particular calcium sulfate (CaSO4·2H2O) and calcium carbonate (CaCO3), are present as solid, micron-sized inclusions within the Greenland GRIP ice core. The compounds are detected by two independent methods: micro...... distributions of the micro-inclusions. These results suggest that water-soluble aerosols in the GRIP ice core are dependable proxies for past atmospheric conditions. Udgivelsesdato: December...

  9. Calpain-GRIP Signaling in Nucleus Accumbens Core Mediates the Reconsolidation of Drug Reward Memory.

    Science.gov (United States)

    Liang, Jie; Li, Jia-Li; Han, Ying; Luo, Yi-Xiao; Xue, Yan-Xue; Zhang, Yàn; Zhang, Yán; Zhang, Li-Bo; Chen, Man-Li; Lu, Lin; Shi, Jie

    2017-09-13

    Exposure to drug-paired cues causes drug memories to be in a destabilized state and interfering with memory reconsolidation can inhibit relapse. Calpain, a calcium-dependent neutral cysteine protease, is involved in synaptic plasticity and the formation of long-term fear memory. However, the role of calpain in the reconsolidation of drug reward memory is still unknown. In the present study, using a conditioned place preference (CPP) model, we found that exposure to drug-paired contextual stimuli induced the activation of calpain and decreased the expression of glutamate receptor interacting protein 1 (GRIP1) in the nucleus accumbens (NAc) core, but not shell, of male rats. Infusions of calpain inhibitors in the NAc core immediately after retrieval disrupted the reconsolidation of cocaine/morphine cue memory and blocked retrieval-induced calpain activation and GRIP1 degradation. The suppressive effect of calpain inhibitors on the expression of drug-induced CPP lasted for at least 14 d. The inhibition of calpain without retrieval 6 h after retrieval or after exposure to an unpaired context had no effects on the expression of reward memory. Calpain inhibition after retrieval also decreased cocaine seeking in a self-administration model and this effect did not recover spontaneously after 28 d. Moreover, the knock-down of GRIP1 expression in the NAc core by lentivirus-mediated short-hairpin RNA blocked disruption of the reconsolidation of drug cue memories that was induced by calpain inhibitor treatment. These results suggest that calpain activity in the NAc core is crucial for the reconsolidation of drug reward memory via the regulation of GRIP1 expression. SIGNIFICANCE STATEMENT Calpain plays an important role in synaptic plasticity and long-term memory consolidation, however, its role in the reconsolidation of drug cue memory remains unknown. Using conditioned place preference and self-administration procedures, we found that exposure to drug-paired cues induced the

  10. Smoking impact on grip strength and fatigue resistance: implications for exercise and hand therapy practice.

    Science.gov (United States)

    Al-Obaidi, Saud; Al-Sayegh, Nowall; Nadar, Mohammed

    2014-07-01

    Grip strength assessment reflects on overall health of the musculoskeletal system and is a predictor of functional prognosis and mortality. The purpose of this study was: examine whether grip-strength and fatigue resistance are impaired in smokers, determine if smoking-related impairments (fatigue-index) can be predicted by demographic data, duration of smoking, packets smoked-per-day, and physical activity. Maximum isometric grip strength (MIGS) of male smokers (n = 111) and nonsmokers (n = 66) was measured before/after induced fatigue using Jamar dynamometer at 5-handle positions. Fatigue index was calculated based on percentage change in MIGS initially and after induced fatigue. Number of repetitions to squeeze the soft rubber ball to induce fatigue was significantly lower in smokers compared with nonsmokers (t = 10.6, P smoking status on MIGS scores was significantly different between smokers and nonsmokers after induced fatigue (β = -3.98, standard error = 0.59, P Smoking status was the strongest significant independent predictor of the fatigue-index. Smokers demonstrated reduced grip strength and fast fatigability in comparison with nonsmokers.

  11. The SAO and Kelvin waves in the EuroGRIPS GCMS and the UK Met. Office analyses

    Directory of Open Access Journals (Sweden)

    M. Amodei

    Full Text Available We compare the tropical oscillations and planetary scale Kelvin waves in four troposphere-stratosphere climate models and the assimilated dataset produced by the United Kingdom Meteorological Office (UKMO. The comparison has been made in the GRIPS framework "GCM-Reality Intercomparison Project for SPARC", where SPARC is Stratospheric Processes and their Role in Climate, a project of the World Climate Research Program. The four models evaluated are European members of GRIPS: the UKMO Unified Model (UM, the model of the Free University in Berlin (FUB–GCM, the ARPEGE-climat model of the French National Centre for Meteorological Research (CNRM, and the Extended UGAMP GCM (EUGCM of the Centre for Global Atmospheric Modelling (CGAM. The integrations were performed with different, but annually periodic external conditions (e.g., sea-surface temperature, sea ice, and incoming solar radiation. The structure of the tropical winds and the strengths of the Kelvin waves are examined. In the analyses where the SAO (Semi-Annual Oscillation and the QBO (Quasi-Biennal Oscillation are reasonably well captured, the amplitude of these analysed Kelvin waves is close to that observed in independent data from UARS (Upper Atmosphere Research Satellite. In agreement with observations, the Kelvin waves generated in the models propagate into the middle atmosphere as wave packets, consistent with a convective forcing origin. In three of the models, slow Kelvin waves propagate too high and their amplitudes are overestimated in the upper stratosphere and in the mesosphere, the exception is the UM which has weaker waves. None of the modelled waves are sufficient to force realistic eastward phases of the QBO or SAO. Although the SAO is represented by all models, only two of them are able to generate westerlies between 10 hPa and 50 hPa. The importance of the role played in the SAO by unresolved gravity waves is emphasized. Although it exhibits some unrealistic features, the

  12. The SAO and Kelvin waves in the EuroGRIPS GCMS and the UK Met. Office analyses

    Directory of Open Access Journals (Sweden)

    M. Amodei

    2001-01-01

    Full Text Available We compare the tropical oscillations and planetary scale Kelvin waves in four troposphere-stratosphere climate models and the assimilated dataset produced by the United Kingdom Meteorological Office (UKMO. The comparison has been made in the GRIPS framework "GCM-Reality Intercomparison Project for SPARC", where SPARC is Stratospheric Processes and their Role in Climate, a project of the World Climate Research Program. The four models evaluated are European members of GRIPS: the UKMO Unified Model (UM, the model of the Free University in Berlin (FUB–GCM, the ARPEGE-climat model of the French National Centre for Meteorological Research (CNRM, and the Extended UGAMP GCM (EUGCM of the Centre for Global Atmospheric Modelling (CGAM. The integrations were performed with different, but annually periodic external conditions (e.g., sea-surface temperature, sea ice, and incoming solar radiation. The structure of the tropical winds and the strengths of the Kelvin waves are examined. In the analyses where the SAO (Semi-Annual Oscillation and the QBO (Quasi-Biennal Oscillation are reasonably well captured, the amplitude of these analysed Kelvin waves is close to that observed in independent data from UARS (Upper Atmosphere Research Satellite. In agreement with observations, the Kelvin waves generated in the models propagate into the middle atmosphere as wave packets, consistent with a convective forcing origin. In three of the models, slow Kelvin waves propagate too high and their amplitudes are overestimated in the upper stratosphere and in the mesosphere, the exception is the UM which has weaker waves. None of the modelled waves are sufficient to force realistic eastward phases of the QBO or SAO. Although the SAO is represented by all models, only two of them are able to generate westerlies between 10 hPa and 50 hPa. The importance of the role played in the SAO by unresolved gravity waves is emphasized. Although it exhibits some unrealistic features, the

  13. Large-scale GWAS identifies multiple loci for hand grip strength providing biological insights into muscular fitness

    NARCIS (Netherlands)

    Willems, Sara M.; Wright, D.J.; Day, Felix R.; Trajanoska, Katerina; Joshi, P.K.; Morris, John A.; Matteini, Amy M.; Garton, Fleur C.; Grarup, Niels; Oskolkov, Nikolay; Thalamuthu, Anbupalam; Mangino, Massimo; Liu, Jun; Demirkan, Ayse; Lek, Monkol; Xu, Liwen; Wang, Guan; Oldmeadow, Christopher; Gaulton, Kyle J.; Lotta, Luca A.; Miyamoto-Mikami, Eri; Rivas, Manuel A.; White, Tom; Loh, Po Ru; Aadahl, Mette; Amin, Najaf; Attia, John R.; Austin, Krista; Benyamin, Beben; Brage, Søren; Cheng, Yu Ching; Ciȩszczyk, Paweł; Derave, Wim; Eriksson, Karl Fredrik; Eynon, Nir; Linneberg, Allan; Lucia, Alejandro; Massidda, Myosotis; Mitchell, Braxton D.; Miyachi, Motohiko; Murakami, Haruka; Padmanabhan, Sandosh; Pandey, Ashutosh; Papadimitriou, Ioannis; Rajpal, Deepak K.; Sale, Craig; Schnurr, Theresia M.; Sessa, Francesco; Shrine, Nick; Tobin, Martin D.; Varley, Ian; Wain, Louise V.; Wray, Naomi R.; Lindgren, Cecilia M.; MacArthur, Daniel G.; Waterworth, Dawn M.; McCarthy, Mark I.; Pedersen, Oluf; Khaw, Kay Tee; Kiel, Douglas P.; Pitsiladis, Yannis; Fuku, Noriyuki; Franks, Paul W.; North, Kathryn N.; Duijn, Van C.M.; Mather, Karen A.; Hansen, Torben; Hansson, Ola; Spector, Tim D.; Murabito, Joanne M.; Richards, J.B.; Rivadeneira, Fernando; Langenberg, Claudia; Perry, John R.B.; Wareham, Nick J.; Scott, Robert A.; Oei, Ling; Zheng, Hou Feng; Forgetta, Vincenzo; Leong, Aaron; Ahmad, Omar S.; Laurin, Charles; Mokry, Lauren E.; Ross, Stephanie; Elks, Cathy E.; Bowden, Jack; Warrington, Nicole M.; Murray, Anna; Ruth, Katherine S.; Tsilidis, Konstantinos K.; Medina-Gómez, Carolina; Estrada, Karol; Bis, Joshua C.; Chasman, Daniel I.; Demissie, Serkalem; Enneman, Anke W.; Hsu, Yi Hsiang; Ingvarsson, Thorvaldur; Kähönen, Mika; Kammerer, Candace; Lacroix, Andrea Z.; Li, Guo; Liu, Ching Ti; Liu, Yongmei; Lorentzon, Mattias; Mägi, Reedik; Mihailov, Evelin; Milani, Lili; Moayyeri, Alireza; Nielson, Carrie M.; Sham, Pack Chung; Siggeirsdotir, Kristin; Sigurdsson, Gunnar; Stefansson, Kari; Trompet, Stella; Thorleifsson, Gudmar; Vandenput, Liesbeth; Velde, Van Der Nathalie; Viikari, Jorma; Xiao, Su Mei; Zhao, Jing Hua; Evans, Daniel S.; Cummings, Steven R.; Cauley, Jane; Duncan, Emma L.; Groot, De Lisette C.P.G.M.; Esko, Tonu; Gudnason, Vilmundar; Harris, Tamara B.; Jackson, Rebecca D.; Jukema, J.W.; Ikram, Arfan M.A.; Karasik, David; Kaptoge, Stephen; Kung, Annie Wai Chee; Lehtimäki, Terho; Lyytikäinen, Leo Pekka; Lips, Paul; Luben, Robert; Metspalu, Andres; Meurs, van Joyce B.; Minster, Ryan L.; Orwoll, Erick; Oei, Edwin; Psaty, Bruce M.; Raitakari, Olli T.; Ralston, Stuart W.; Ridker, Paul M.; Robbins, John A.; Smith, Albert V.; Styrkarsdottir, Unnur; Tranah, Gregory J.; Thorstensdottir, Unnur; Uitterlinden, Andre G.; Zmuda, Joseph; Zillikens, M.C.; Ntzani, Evangelia E.; Evangelou, Evangelos; Ioannidis, John P.A.; Evans, David M.; Ohlsson, Claes

    2017-01-01

    Hand grip strength is a widely used proxy of muscular fitness, a marker of frailty, and predictor of a range of morbidities and all-cause mortality. To investigate the genetic determinants of variation in grip strength, we perform a large-scale genetic discovery analysis in a combined sample of

  14. Is grip strength a predictor for total muscle strength in healthy children, adolescents, and young adults?

    NARCIS (Netherlands)

    Wind, Anne E.; Takken, Tim; Helders, Paul J. M.; Engelbert, Raoul H. H.

    2010-01-01

    The primary purpose of this study was to examine whether grip strength is related to total muscle strength in children, adolescents, and young adults. The second purpose was to provide reference charts for grip strength, which could be used in the clinical and research setting. This cross-sectional

  15. Getting a grip: different actions and visual guidance of the thumb and finger in precision grasping.

    Science.gov (United States)

    Melmoth, Dean R; Grant, Simon

    2012-10-01

    We manipulated the visual information available for grasping to examine what is visually guided when subjects get a precision grip on a common class of object (upright cylinders). In Experiment 1, objects (2 sizes) were placed at different eccentricities to vary the relative proximity to the participant's (n = 6) body of their thumb and finger contact positions in the final grip orientations, with vision available throughout or only for movement programming. Thumb trajectories were straighter and less variable than finger paths, and the thumb normally made initial contact with the objects at a relatively invariant landing site, but consistent thumb first-contacts were disrupted without visual guidance. Finger deviations were more affected by the object's properties and increased when vision was unavailable after movement onset. In Experiment 2, participants (n = 12) grasped 'glow-in-the-dark' objects wearing different luminous gloves in which the whole hand was visible or the thumb or the index finger was selectively occluded. Grip closure times were prolonged and thumb first-contacts disrupted when subjects could not see their thumb, whereas occluding the finger resulted in wider grips at contact because this digit remained distant from the object. Results were together consistent with visual feedback guiding the thumb in the period just prior to contacting the object, with the finger more involved in opening the grip and avoiding collision with the opposite contact surface. As people can overtly fixate only one object contact point at a time, we suggest that selecting one digit for online guidance represents an optimal strategy for initial grip placement. Other grasping tasks, in which the finger appears to be used for this purpose, are discussed.

  16. Large-scale GWAS identifies multiple loci for hand grip strength providing biological insights into muscular fitness

    DEFF Research Database (Denmark)

    Willems, Sara M.; Wright, Daniel J.; Day, Felix R.

    2017-01-01

    Hand grip strength is a widely used proxy of muscular fitness, a marker of frailty, and predictor of a range of morbidities and all-cause mortality. To investigate the genetic determinants of variation in grip strength, we perform a large-scale genetic discovery analysis in a combined sample of 1...

  17. The flow field acting on the fluttering profile, kinematics, forces and total moment

    Czech Academy of Sciences Publication Activity Database

    Kozánek, Jan; Vlček, Václav; Zolotarev, Igor

    2013-01-01

    Roč. 13, č. 7 (2013), s. 1-7 ISSN 0219-4554 R&D Projects: GA ČR GA101/09/1522 Institutional support: RVO:61388998 Keywords : fluttering profile * interferometry visualization * acting forces and moment Subject RIV: JU - Aeronautics, Aerodynamics, Aircrafts Impact factor: 1.059, year: 2013

  18. EFFECT OF ECCENTRIC EXERCISE PROGRAMME ON PAIN AND GRIP STRENGTH FOR SUBJECTS WITH MEDIAL EPICONDYLITIS

    Directory of Open Access Journals (Sweden)

    Mishra Prashant Akhilesh

    2014-04-01

    Full Text Available Background and Objective: Therapeutic eccentric exercise may provide both a structural and functional benefit during tendinopathy rehabilitation. The objective is to find the effect of eccentric exercises on improvement of pain and grip strength for subjects with Medial Epicondylitis. Method: Pre to post test experimental study design randomized thirty subjects with medial epicondylitis, 15 each into Group A and Group B. Group B subjects were treated with conventional therapy and Eccentric exercises. Group A subjects were treated with conventional therapy. Results: When means of post intervention were compared using Independent ‘t’ between groups there was no statistically significant difference in improvements obtained in VAS scores and grip strength. There was a statistically significant change in means of VAS score and Grip strength when means were analyzed by using Paired‘t’ test and Wilcoxon signed rank test within the groups with positive percentage of change. Conclusion: It is concluded that four weeks of Eccentric Exercise Programme combined with conventional therapy shown significant effect on improving pain and Grip strength, however the improvement obtained has no difference when compared with control conventional treatment for Subjects with Medial Epicondylitis.

  19. Anticipatory planning and control of grasp positions and forces for dexterous two-digit manipulation.

    Science.gov (United States)

    Fu, Qiushi; Zhang, Wei; Santello, Marco

    2010-07-07

    Dexterous object manipulation requires anticipatory control of digit positions and forces. Despite extensive studies on sensorimotor learning of digit forces, how humans learn to coordinate digit positions and forces has never been addressed. Furthermore, the functional role of anticipatory modulation of digit placement to object properties remains to be investigated. We addressed these questions by asking human subjects (12 females, 12 males) to grasp and lift an inverted T-shaped object using precision grip at constrained or self-chosen locations. The task requirement was to minimize object roll during lift. When digit position was not constrained, subjects could have implemented many equally valid digit position-force coordination patterns. However, choice of digit placement might also have resulted in large trial-to-trial variability of digit position, hence challenging the extent to which the CNS could have relied on sensorimotor memories for anticipatory control of digit forces. We hypothesized that subjects would modulate digit placement for optimal force distribution and digit forces as a function of variable digit positions. All subjects learned to minimize object roll within the first three trials, and the unconstrained device was associated with significantly smaller grip forces but larger variability of digit positions. Importantly, however, digit load force modulation compensated for position variability, thus ensuring consistent object roll minimization on each trial. This indicates that subjects learned object manipulation by integrating sensorimotor memories with sensory feedback about digit positions. These results are discussed in the context of motor equivalence and sensorimotor integration of grasp kinematics and kinetics.

  20. A novel mechanism of hippocampal LTD involving muscarinic receptor-triggered interactions between AMPARs, GRIP and liprin-α

    Directory of Open Access Journals (Sweden)

    Dickinson Bryony A

    2009-06-01

    Full Text Available Abstract Background Long-term depression (LTD in the hippocampus can be induced by activation of different types of G-protein coupled receptors, in particular metabotropic glutamate receptors (mGluRs and muscarinic acethycholine receptors (mAChRs. Since mGluRs and mAChRs activate the same G-proteins and isoforms of phospholipase C (PLC, it would be expected that these two forms of LTD utilise the same molecular mechanisms. However, we find a distinct mechanism of LTD involving GRIP and liprin-α. Results Whilst both forms of LTD require activation of tyrosine phosphatases and involve internalisation of AMPARs, they use different molecular interactions. Specifically, mAChR-LTD, but not mGluR-LTD, is blocked by peptides that inhibit the binding of GRIP to the AMPA receptor subunit GluA2 and the binding of GRIP to liprin-α. Thus, different receptors that utilise the same G-proteins can regulate AMPAR trafficking and synaptic efficacy via distinct molecular mechanisms. Conclusion Our results suggest that mAChR-LTD selectively involves interactions between GRIP and liprin-α. These data indicate a novel mechanism of synaptic plasticity in which activation of M1 receptors results in AMPAR endocytosis, via a mechanism involving interactions between GluA2, GRIP and liprin-α.

  1. Serotonergic-postsynaptic receptors modulate gripping-induced immobility episodes in male taiep rats.

    Science.gov (United States)

    Eguibar, José R; Cortés, M C; Ita, M L

    2009-09-01

    The Taiep rat is a myelin mutant with a motor syndrome characterized by tremor, ataxia, immobility, epilepsy, and paralysis. The rat shows a hypomyelination followed by a progressive demyelination. During immobilities taiep rats show a REM-like sleep pattern and a disorganized sleep-wake pattern suggesting taiep rats as a model of narcolepsy-cataplexy. Our study analyzed the role of postsynaptic serotonin receptors in the expression of gripping-induced immobility episodes (IEs) in 8-month-old male taiep rats. The specific postsynaptic serotonin agonist +/-1-(2,5-dimethoxy-4-iodoamphetamine hydrochloride (+/-DOI) decreased the frequency of gripping-induced IEs, but that was not the case with alpha-methyl-serotonin maleate (alpha-methyl-5HT), a nonspecific postsynaptic agonist. Although the serotonin antagonists, ketanserine and metergoline, produced a biphasic effect, first a decrease followed by an increase with higher doses, similar effects were obtained with a mean duration of gripping-induced IEs. These findings correlate with the pharmacological observations in narcoleptic dogs and humans in which serotonin-reuptake inhibitors improve cataplexy, particularly in long-term treatment that could change the serotonin receptor levels. Polysomnographic recordings showed an increase in the awakening time and a decrease in the slow wave and rapid eye movement sleep concomitant with a decrease in immobilities after use of +/-DOI, this being stronger with the highest dose. Taken together, our results show that postsynaptic serotonin receptors are involved in the modulation in gripping-induced IEs caused by the changes in the organization of the sleep-wake cycle in taiep rats. It is possible that specific agonists, without side effects, could be a useful treatment in human narcoleptic patients. 2009 Wiley-Liss, Inc.

  2. INDICATORS OF MAXIMAL FLEXOR FORCE OF LEFT AND RIGHT HAND FOR THE POLICE SELECTION CRITERIA PURPOSES

    Directory of Open Access Journals (Sweden)

    Milivoj Dopsaj

    2006-06-01

    Full Text Available As a part of their professional responsibilities, police officers have authorization, in situation determined by law, to apply physical force or means of force. Due to given professional reasons, selection among the candidates as well as routine physical capability assessments, should have professional-methodological basis and scientific foundation. Muscle groups of particular reference in relationship to estimate general contraction characteristic in regard to force, and at the same time very easy to test are flexor muscles of fingers of the hand (test “hand squeeze”. The aim of this research is to define criterion characteristic for the population to function for selection and estimation of the hand squeeze force among policemen. This research had 723 participants, students of the Police Academy, as representatives of policemen between 19 and 24 years of age. In order to estimate force of hand grip (both right and left hand, we utilized tensiometric method, and standard procedure previously described (1. For the statistical analysis we used basic descriptive analysis, cluster analysis (defining 7 characteristic classes (clusters as a function of population tested –unacceptable, poor, below average, averaged, above average, excellent and superior, and factor analysis (definition of the selection test as a function of selection procedure (10. Our results indicate that averaged hand grip force among the tested population is 61.70±8.97 DaN (Min – Max=43.43-101.41 for left hand, and 65.11±9.34 DaN (Min – Max= 46.54-109.75 for right hand. The values for the force of defined cluster centers of left hand are: Cluster1-7=50.22, 55.76, 61.61, 67.84, 74.71, 84.02 and 97.15 DaN, and right hand are: Cluster1-7=53.40, 60.27, 66.10, 72.20, 79.70, 92.55 and 105.65 DaNFactor analysis results have shown that one factor has been isolated that accounted for 91.10 worthy variance. Regarding the individual variability, for the saturation of the isolated

  3. Large-scale GWAS identifies multiple loci for hand grip strength providing biological insights into muscular fitness

    DEFF Research Database (Denmark)

    Willems, Sara M; Wright, Daniel J.; Day, Felix R

    2017-01-01

    with involvement of psychomotor impairment (PEX14, LRPPRC and KANSL1). Mendelian randomization analyses are consistent with a causal effect of higher genetically predicted grip strength on lower fracture risk. In conclusion, our findings provide new biological insight into the mechanistic underpinnings of grip...... strength and the causal role of muscular strength in age-related morbidities and mortality....

  4. Grip strength and lower limb extension power in 19-72-year-old Danish men and women

    DEFF Research Database (Denmark)

    Aadahl, Mette; Beyer, Nina; Linneberg, Allan

    2011-01-01

    To assess muscular fitness by hand grip strength (HGS) and lower limb extension power (LEP) and to explore associations with age, leisure time physical activity (LTPA) and body composition.......To assess muscular fitness by hand grip strength (HGS) and lower limb extension power (LEP) and to explore associations with age, leisure time physical activity (LTPA) and body composition....

  5. Initial Effect of Taping Technique on Wrist Extension and Grip Strength and Pain of Individuals with Lateral Epicondylitis

    Directory of Open Access Journals (Sweden)

    Alireza Shamsoddini

    2010-04-01

    Full Text Available Objectives: Aim of this study is to investigate the initial effect of taping technique on wrist extension and grip strength and pain of Individuals with tennis elbow. Methods: fifteen patients (10 men and 5 women with 42.53 years on their dominant arm participated in this study. Outcome measures were wrist extension and grip strength and pain taken before and immediately after application of tape. The unaffected arm served as a control. Used of hand-held dynamometer and jammar dynamometer for evaluated of wrist extension and grip strength. Also, visual analog scale (VAS used for evaluated of pain Results: Among the variables, significant differences were found in wrist extension strength between effected and unaffected arm (P=0.006. Also, changes in grip strength shows statically significant improve in effect arm than unaffected arm (P=0.001. Changes in pain in impaired arm were positive. Discussion: Taping technique, as applied in this study demonstrated an impressive effect on wrist extension and grip strength and pain in individuals with tennis elbow. Therefore, it is recommended that this method may be useful in the management of this condition during exercise and functional rehabilitation.

  6. Gripped by movies: From story-world to artifact absorption

    NARCIS (Netherlands)

    Doicaru, M.M.

    2016-01-01

    That movies are a great source of entertainment seems to be common sense. But how exactly movies manage to get large audiences absorbed, or what is their gripping tool is still a mystery. Research makes use of different concepts pointing to narrative absorption, but it is not clear how they differ

  7. Improved Friction Joint With Self-Locking Grips

    DEFF Research Database (Denmark)

    Costache, Andrei; Glejbøl, Kristian; Sivebæk, Ion Marius

    2016-01-01

    Flexible risers are used in the oil industry to transport liquids and gas from the seafloorto extraction and production equipment at the sea surface. Ongoing research aims at using composite materials instead of steel, in order to reduce weight and increase stiffness. Ensuring an optimal load......-depth understanding of the influence between friction, geometrical parameters,and performance, making it possible to optimize the design. Results show that this grip system offers immediate technical applications, in a variety of conditions....

  8. Fingers' vibration transmission and grip strength preservation performance of vibration reducing gloves.

    Science.gov (United States)

    Hamouda, K; Rakheja, S; Dewangan, K N; Marcotte, P

    2018-01-01

    The vibration isolation performances of vibration reducing (VR) gloves are invariably assessed in terms of power tools' handle vibration transmission to the palm of the hand using the method described in ISO 10819 (2013), while the nature of vibration transmitted to the fingers is ignored. Moreover, the VR gloves with relatively low stiffness viscoelastic materials affect the grip strength in an adverse manner. This study is aimed at performance assessments of 12 different VR gloves on the basis of handle vibration transmission to the palm and the fingers of the gloved hand, together with reduction in the grip strength. The gloves included 3 different air bladder, 3 gel, 3 hybrid, and 2 gel-foam gloves in addition to a leather glove. Two Velcro finger adapters, each instrumented with a three-axis accelerometer, were used to measure vibration responses of the index and middle fingers near the mid-phalanges. Vibration transmitted to the palm was measured using the standardized palm adapter. The vibration transmissibility responses of the VR gloves were measured in the laboratory using the instrumented cylindrical handle, also described in the standard, mounted on a vibration exciter. A total of 12 healthy male subjects participated in the study. The instrumented handle was also used to measure grip strength of the subjects with and without the VR gloves. The results of the study showed that the VR gloves, with only a few exceptions, attenuate handle vibration transmitted to the fingers only in the 10-200 Hz and amplify middle finger vibration at frequencies exceeding 200 Hz. Many of the gloves, however, provided considerable reduction in vibration transmitted to the palm, especially at higher frequencies. These suggest that the characteristics of vibration transmitted to fingers differ considerably from those at the palm. Four of the test gloves satisfied the screening criteria of the ISO 10819 (2013) based on the palm vibration alone, even though these caused

  9. Stress examination of flexor tendon pulley rupture in the crimp grip position: a 1.5-Tesla MRI cadaver study

    Energy Technology Data Exchange (ETDEWEB)

    Bayer, Thomas; Janka, Rolf [University of Erlangen-Nuremberg, Department of Radiology, Erlangen (Germany); Fries, Simon [Cantonal Hospital Lucerne, Orthopaedic Department, Wolhusen (Switzerland); Schweizer, Andreas [University of Zurich, Department of Orthopaedics, Balgrist, Zurich (Switzerland); Schoeffl, Isabelle [Klinikum Bamberg, Department of Pediatrics, Bamberg (Germany); Bongartz, Georg [University Basel, Department of Radiology, Basel (Switzerland)

    2015-01-15

    The objectives of this study were the evaluation of flexor tendon pulley rupture of the fingers in the crimp grip position using magnetic resonance imaging (MRI) and the comparison of the results with MRI in the neutral position in a cadaver study. MRI in the crimp grip position and in the neutral position was performed in 21 cadaver fingers with artificially created flexor tendon pulley tears (combined pulley rupture, n = 14; single pulley rupture, n = 7). Measurement of the distance between the tendon and bone was performed. Images were evaluated by two readers, first independently and in cases of discrepancy in consensus. Sensitivity and specificity for detecting combined pulley ruptures were calculated. Tendon bone distances were significantly higher in the crimp grip position than in the neutral position. Sensitivity and specificity for detecting combined pulley rupture were 92.86 % and 100 % respectively in the crimp grip position and 78.57 % and 85.71 % respectively in the neutral position. Kappa values for interobserver reliability were 0.87 in the crimp grip position and 0.59 in the neutral position. MRI examination in the crimp grip position results in higher tendon bone distances by subjecting the pulleys to a higher strain, which facilitates image evaluation with higher interobserver reliability, higher sensitivity, and higher specificity for combined pulley rupture compared with examination in the neutral position. (orig.)

  10. Hand grip endurance test relates to clinical state and prognosis in COPD patients better than 6-minute walk test distance

    Directory of Open Access Journals (Sweden)

    Kovarik M

    2017-12-01

    Full Text Available Miroslav Kovarik,1,2 Vera Joskova,1,2 Anna Patkova,1,2 Vladimir Koblizek,3 Zdenek Zadak,2 Miloslav Hronek1,2 1Department of Biological and Medical Sciences, Faculty of Pharmacy in Hradec Kralove, Charles University, Hradec Kralove, Czech Republic; 2Department of Research and Development, University Hospital Hradec Kralove, Hradec Kralove, Czech Republic; 3Department of Pulmonary Medicine, University Hospital Hradec Kralove, Hradec Kralove, Czech Republic Purpose: Patients with COPD present peripheral muscle dysfunction and atrophy, expressed as muscle strength and endurance reduction. The goal of this study was direct dynamometric assessment of hand grip endurance and strength in relation to the stage of disease, multidimensional predictors of mortality, and 6-minute walk test (6MWT. To the best of our knowledge, there has been no previous study determining these parameters.Patients and methods: In this observational study, 58 consecutive outpatients with stable COPD and 25 volunteers without respiratory problems were compared. All COPD subjects underwent a comprehensive examination to determine COPD severity, prognostic scales, and 6MWT. Body composition, basic spirometric parameters, and hand grip strength and endurance were determined in all study participants.Results: Patients in the COPD group had a 15% decrease in maximum strength (P=0.012 and a 28% decrease in area under the force/time curve (AUC of the endurance test (P<0.001 compared to the control group. Dynamometric parameters were significantly negatively associated with the stage of disease and values of multivariable prediction indexes, and positively associated with the results of 6MWT. In most cases, closer associations were found with AUC than with 6MWT and in the gender-specific groups.Conclusion: Both hand grip strength and endurance are impaired in COPD patients in comparison with the control group. In particular, AUC could be considered as an attractive option not only to

  11. Cortical activation during power grip task with pneumatic pressure gauge: an fMRI study

    Science.gov (United States)

    Mohamad, M.; Mardan, N. H.; Ismail, S. S.

    2017-05-01

    Aging is associated with a decline in cognitive and motor function. But, the relationships with motor performance are less well understood. In this study, functional magnetic resonance imaging (fMRI) was used to assess cortical activation in older adults. This study employed power grip task that utilised block paradigm consisted of alternate 30s rest and active. A visual cue was used to pace the hand grip movement that clenched a cylindrical rubber bulb connected with pressure pneumatic gauge that measure the pressure (Psi). The objective of this study is determined the brain areas activated during motor task and the correlation between percentage signal change of each motor area (BA 4 and 6) and hand grip pressure. Result showed there was a significant difference in mean percentage signal change in BA 4 and BA 6 in both hemispheres and negative correlation obtained in BA 4 and BA 6. These results indicate that a reduced ability in the motor networks contribute to age-related decline in motor performance.

  12. Estimating thumb–index finger precision grip and manipulation potential in extant and fossil primates

    Science.gov (United States)

    Feix, Thomas; Kivell, Tracy L.; Pouydebat, Emmanuelle; Dollar, Aaron M.

    2015-01-01

    Primates, and particularly humans, are characterized by superior manual dexterity compared with other mammals. However, drawing the biomechanical link between hand morphology/behaviour and functional capabilities in non-human primates and fossil taxa has been challenging. We present a kinematic model of thumb–index precision grip and manipulative movement based on bony hand morphology in a broad sample of extant primates and fossil hominins. The model reveals that both joint mobility and digit proportions (scaled to hand size) are critical for determining precision grip and manipulation potential, but that having either a long thumb or great joint mobility alone does not necessarily yield high precision manipulation. The results suggest even the oldest available fossil hominins may have shared comparable precision grip manipulation with modern humans. In particular, the predicted human-like precision manipulation of Australopithecus afarensis, approximately one million years before the first stone tools, supports controversial archaeological evidence of tool-use in this taxon. PMID:25878134

  13. Grip Strength as an Indicator of Health-Related Quality of Life in Old Age-A Pilot Study.

    Science.gov (United States)

    Musalek, Christina; Kirchengast, Sylvia

    2017-11-24

    Over the last century life expectancy has increased dramatically nearly all over the world. This dramatic absolute and relative increase of the old aged people component of the population has influenced not only population structure but also has dramatic implications for the individuals and public health services. The aim of the present pilot study was to examine the impact of physical well-being assessed by hand grip strength and social factors estimated by social contact frequency on health-related quality of life among 22 men and 41 women ranging in age between 60 and 94 years. Physical well-being was estimated by hand grip strength, data concerning subjective wellbeing and health related quality of life were collected by personal interviews based on the WHOQOL-BREF questionnaires. Number of offspring and intergenerational contacts were not related significantly to health-related quality of life, while social contacts with non-relatives and hand grip strength in contrast had a significant positive impact on health related quality of life among old aged men and women. Physical well-being and in particular muscle strength-estimated by grip strength-may increase health-related quality of life and is therefore an important source for well-being during old age. Grip strength may be used as an indicator of health-related quality of life.

  14. Determining concentration depth profiles in fluorinated networks by means of electric force microscopy

    International Nuclear Information System (INIS)

    Miccio, Luis A.; Kummali, Mohammed M.; Alegria, Angel; Montemartini, Pablo E.; Oyanguren, Patricia A.; Schwartz, Gustavo A.; Colmenero, Juan

    2011-01-01

    By means of electric force microscopy, composition depth profiles were measured with nanometric resolution for a series of fluorinated networks. By mapping the dielectric permittivity along a line going from the surface to the bulk, we were able to experimentally access to the fluorine concentration profile. Obtained data show composition gradient lengths ranging from 30 nm to 80 nm in the near surface area for samples containing from 0.5 to 5 wt. % F, respectively. In contrast, no gradients of concentration were detected in bulk. This method has several advantages over other techniques because it allows profiling directly on a sectional cut of the sample. By combining the obtained results with x-ray photoelectron spectroscopy measurements, we were also able to quantify F/C ratio as a function of depth with nanoscale resolution.

  15. Normative static grip strength of population of Turkey, effects of various factors and a comparison with international norms.

    Science.gov (United States)

    Ekşioğlu, Mahmut

    2016-01-01

    Normative data are of importance in ergonomics and clinical settings. Applying normative data internationally is questionable. To this end, this study aimed to establish gender- and age-specific reference values for static (isometric) hand grip strength of normal population of Turkey with special regard to occupational demand, and compare them with the international norms. The secondary aims were to investigate the effects of gender, age-group, weight-group, job-group, hand and several anthropometric variables on static grip strength. A sample of 211 (128 male and 83 female) volunteers aged between 18 and 69 with various occupations participated in the study. Grip strength data were collected using a Jamar dynamometer with standard testing position, protocol and instructions. The mean and std deviation of maximum voluntary static grip strength values (in N) for dominant and non-dominant hands respectively were 455.2 ± 73.6 and 441.5 ± 72.6 for males, and 258 ± 46.1 and 246.2 ± 49.1 for females. The mean female strength was about 57% of the mean male strength value for both dominant and non-dominant hands. There was a curvilinear relationship of grip strength to age, significant differences between genders, hands, and some age-groups, and a correlation to height, body-mass, BMI and hand dimensions depending on the gender. The comparisons with the norms of other world populations indicate that there are cross-national grip strength variations among some nations but not all. Copyright © 2015 Elsevier Ltd and The Ergonomics Society. All rights reserved.

  16. Oxytocin decreases handgrip force in reaction to infant crying in females without harsh parenting experiences

    NARCIS (Netherlands)

    Bakermans-Kranenburg, M.J.; van IJzendoorn, M.H.; Riem, M.M.E.; Tops, M.; Alink, L.R.A.

    2012-01-01

    Infant crying can elicit sensitive caregiving as well as hostility and harsh parenting responses. In the current study (N=42 females) with a double-blind experimental design, we tested the effect of intranasal oxytocin administration on the use of excessive force using a hand-grip dynamometer during

  17. Testing the efficacy of existing force-endurance models to account for the prevalence of obesity in the workforce.

    Science.gov (United States)

    Pajoutan, Mojdeh; Cavuoto, Lora A; Mehta, Ranjana K

    2017-10-01

    This study evaluates whether the existing force-endurance relationship models are predictive of endurance time for overweight and obese individuals, and if not, provide revised models that can be applied for ergonomics practice. Data was collected from 141 participants (49 normal weight, 50 overweight, 42 obese) who each performed isometric endurance tasks of hand grip, shoulder flexion, and trunk extension at four levels of relative workload. Subject-specific fatigue rates and a general model of the force-endurance relationship were determined and compared to two fatigue models from the literature. There was a lack of fit between previous models and the current data for the grip (ICC = 0.8), with a shift toward lower endurance times for the new data. Application of the revised models can facilitate improved workplace design and job evaluation to accommodate the capacities of the current workforce.

  18. Transcranial direct current stimulation over multiple days enhances motor performance of a grip task.

    Science.gov (United States)

    Fan, Julie; Voisin, Julien; Milot, Marie-Hélène; Higgins, Johanne; Boudrias, Marie-Hélène

    2017-09-01

    Recovery of handgrip is critical after stroke since it is positively related to upper limb function. To boost motor recovery, transcranial direct current stimulation (tDCS) is a promising, non-invasive brain stimulation technique for the rehabilitation of persons with stroke. When applied over the primary motor cortex (M1), tDCS has been shown to modulate neural processes involved in motor learning. However, no studies have looked at the impact of tDCS on the learning of a grip task in both stroke and healthy individuals. To assess the use of tDCS over multiple days to promote motor learning of a grip task using a learning paradigm involving a speed-accuracy tradeoff in healthy individuals. In a double-blinded experiment, 30 right-handed subjects (mean age: 22.1±3.3 years) participated in the study and were randomly assigned to an anodal (n=15) or sham (n=15) stimulation group. First, subjects performed the grip task with their dominant hand while following the pace of a metronome. Afterwards, subjects trained on the task, at their own pace, over 5 consecutive days while receiving sham or anodal tDCS over M1. After training, subjects performed de novo the metronome-assisted task. The change in performance between the pre and post metronome-assisted task was used to assess the impact of the grip task and tDCS on learning. Anodal tDCS over M1 had a significant effect on the speed-accuracy tradeoff function. The anodal tDCS group showed significantly greater improvement in performance (39.28±15.92%) than the sham tDCS group (24.06±16.35%) on the metronome-assisted task, t(28)=2.583, P=0.015 (effect size d=0.94). Anodal tDCS is effective in promoting grip motor learning in healthy individuals. Further studies are warranted to test its potential use for the rehabilitation of fine motor skills in stroke patients. Copyright © 2017 Elsevier Masson SAS. All rights reserved.

  19. Associations between aging-related changes in grip strength and cognitive function in older adults: A systematic review.

    Science.gov (United States)

    Zammit, Andrea R; Robitaille, Annie; Piccinin, Andrea; Muniz-Terrera, Graciela; Hofer, Scott M

    2018-03-08

    Grip strength and cognitive function reflect upper body muscle strength and mental capacities. Cross-sectional research has suggested that in old age these two processes are moderately to highly associated, and that an underlying common cause drives this association. Our aim was to synthesize and evaluate longitudinal research addressing whether changes in grip strength are associated with changes in cognitive function in healthy older adults. We systematically reviewed English-language research investigating the longitudinal association between repeated measures of grip strength and of cognitive function in community-dwelling older adults to evaluate the extent to which the two indices decline concurrently. We used four search engines: Embase, PsychINFO, PubMed, and Web of Science. Of 459 unique citations, 6 met our full criteria: 4 studies reported a longitudinal association between rates of change in grip strength and cognitive function in older adults, 2 of which reported the magnitudes of these associations as ranging from low to moderate; 2 studies reported significant cross-sectional but not longitudinal associations among rates of change. All studies concluded that cognitive function and grip strength declined, on average, with increasing age, although with little to no evidence for longitudinal associations among rates of change. Future research is urged to expand the study of physical and cognitive associations in old age using a within-person and multi-study integrative approach to evaluate the reliability of longitudinal results with greater emphasis on the magnitude of this association.

  20. Grip Strength Is Associated With Cognitive Performance in Schizophrenia and the General Population: A UK Biobank Study of 476559 Participants.

    Science.gov (United States)

    Firth, Joseph; Stubbs, Brendon; Vancampfort, Davy; Firth, Josh A; Large, Matthew; Rosenbaum, Simon; Hallgren, Mats; Ward, Philip B; Sarris, Jerome; Yung, Alison R

    2018-04-19

    Handgrip strength may provide an easily-administered marker of cognitive functional status. However, further population-scale research examining relationships between grip strength and cognitive performance across multiple domains is needed. Additionally, relationships between grip strength and cognitive functioning in people with schizophrenia, who frequently experience cognitive deficits, has yet to be explored. Baseline data from the UK Biobank (2007-2010) was analyzed; including 475397 individuals from the general population, and 1162 individuals with schizophrenia. Linear mixed models and generalized linear mixed models were used to assess the relationship between grip strength and 5 cognitive domains (visual memory, reaction time, reasoning, prospective memory, and number memory), controlling for age, gender, bodyweight, education, and geographical region. In the general population, maximal grip strength was positively and significantly related to visual memory (coefficient [coeff] = -0.1601, standard error [SE] = 0.003), reaction time (coeff = -0.0346, SE = 0.0004), reasoning (coeff = 0.2304, SE = 0.0079), number memory (coeff = 0.1616, SE = 0.0092), and prospective memory (coeff = 0.3486, SE = 0.0092: all P reasoning (P > .1). Grip strength is significantly associated with cognitive functioning in the general population and individuals with schizophrenia, particularly for working memory and processing speed. Future research should establish directionality, examine if grip strength also predicts functional and physical health outcomes in schizophrenia, and determine whether interventions which improve muscular strength impact on cognitive and real-world functioning.

  1. Effect of Insoles with a Toe-Grip Bar on Toe Function and Standing Balance in Healthy Young Women: A Randomized Controlled Trial

    Directory of Open Access Journals (Sweden)

    Hideki Nakano

    2017-01-01

    Full Text Available Objective. The aim of this randomized controlled study was to investigate the effects of insoles with a toe-grip bar on toe function and standing balance in healthy young women. Methods. Thirty female subjects were randomly assigned to an intervention group or a control group. The intervention group wore shoes with insoles with a toe-grip bar. The control group wore shoes with general insoles. Both groups wore the shoes for 4 weeks, 5 times per week, 9 hours per day. Toe-grip strength, toe flexibility, static balance (total trajectory length and envelope area of the center of pressure, and dynamic balance (functional reach test were measured before and after the intervention. Results. Significant interactions were observed for toe-grip strength and toe flexibility (F=12.53, p<0.01; F=5.84, p<0.05, resp., with significant improvement in the intervention group compared with that in the control group. Post hoc comparisons revealed that both groups showed significant improvement in toe-grip strength (p<0.01 and p<0.05, resp., with higher benefits observed for the intervention group (p<0.01. Conversely, no significant interaction was observed in the total trajectory length, envelope area, and functional reach test. Conclusions. This study suggests that insoles with a toe-grip bar contribute to improvements in toe-grip strength and toe flexibility in healthy young women.

  2. Nutritional status is the major factor affecting grip strength of African HIV patients before and during antiretroviral treatment

    DEFF Research Database (Denmark)

    Filteau, Suzanne; PrayGod, G; Woodd, Susannah L

    2017-01-01

    OBJECTIVES: Low grip strength is a marker of frailty and a risk factor for mortality among HIV patients and other populations. We investigated factors associated with grip strength in malnourished HIV patients at referral to ART, and at 12 weeks and 2-3 years after starting ART. METHODS: The study...... involved HIV-infected Zambian and Tanzanian participants recruited to the NUSTART trial when malnourished (body mass index .... CONCLUSIONS: In this population of originally malnourished HIV patients, poor grip strength was more strongly and independently associated with nutritional than with infection and inflammation variables. Programmes to improve health and survival of HIV patients should incorporate nutritional assessment...

  3. Cortical activation during power grip task with pneumatic pressure gauge: an fMRI study

    International Nuclear Information System (INIS)

    Mohamad, M; Ismail, S S; Mardan, N H

    2017-01-01

    Aging is associated with a decline in cognitive and motor function. But, the relationships with motor performance are less well understood. In this study, functional magnetic resonance imaging (fMRI) was used to assess cortical activation in older adults. This study employed power grip task that utilised block paradigm consisted of alternate 30s rest and active. A visual cue was used to pace the hand grip movement that clenched a cylindrical rubber bulb connected with pressure pneumatic gauge that measure the pressure (Psi). The objective of this study is determined the brain areas activated during motor task and the correlation between percentage signal change of each motor area (BA 4 and 6) and hand grip pressure. Result showed there was a significant difference in mean percentage signal change in BA 4 and BA 6 in both hemispheres and negative correlation obtained in BA 4 and BA 6. These results indicate that a reduced ability in the motor networks contribute to age-related decline in motor performance. (paper)

  4. Estimating thumb-index finger precision grip and manipulation potential in extant and fossil primates.

    Science.gov (United States)

    Feix, Thomas; Kivell, Tracy L; Pouydebat, Emmanuelle; Dollar, Aaron M

    2015-05-06

    Primates, and particularly humans, are characterized by superior manual dexterity compared with other mammals. However, drawing the biomechanical link between hand morphology/behaviour and functional capabilities in non-human primates and fossil taxa has been challenging. We present a kinematic model of thumb-index precision grip and manipulative movement based on bony hand morphology in a broad sample of extant primates and fossil hominins. The model reveals that both joint mobility and digit proportions (scaled to hand size) are critical for determining precision grip and manipulation potential, but that having either a long thumb or great joint mobility alone does not necessarily yield high precision manipulation. The results suggest even the oldest available fossil hominins may have shared comparable precision grip manipulation with modern humans. In particular, the predicted human-like precision manipulation of Australopithecus afarensis, approximately one million years before the first stone tools, supports controversial archaeological evidence of tool-use in this taxon. © 2015 The Author(s) Published by the Royal Society. All rights reserved.

  5. An instrumented object for hand exercise and assessment using a pneumatic pressure sensor

    Science.gov (United States)

    Mohan, A.; Tharion, G.; Kumar, R. K.; Devasahayam, S. R.

    2018-05-01

    Measurement of grip force is important for both exercise training and assessment of the hand during physical rehabilitation. The standard method uses a grip dynamometer which measures the force between the fingers and opposing thumb. The primary limitation of the grip dynamometer is the restriction of measurement to cylindrical grasps. Any deformation of the hand due to muscular or skeletal disease makes the grip dynamometer difficult or impossible to use. An alternative to the grip dynamometer is a sealed pneumatic object that can be gripped by the hand. Measurement of the internal pressure in the object can be related to the grip force. In this paper, we analyze such a pneumatic pressure sensing object for hand grip assessment and also describe an easy fabrication of the grip sensor. The instrumented object presented in this paper is designed to assess both the maximal voluntary grip forces and continuous grip force to monitor control of hand function during exercise under instruction from a therapist. Potential uses of such a pneumatic pressure sensing object for hand grip are in physical rehabilitation of patients following paralysing illnesses like stroke and spinal cord injury.

  6. Grip strength and quality of life in the second half of life: hope as a moderator.

    Science.gov (United States)

    Gum, Amber M; Segal-Karpas, Dikla; Avidor, Sharon; Ayalon, Liat; Bodner, Ehud; Palgi, Yuval

    2017-09-28

    The purpose of the current study was to investigate grip strength, hope, and their interaction as predictors of quality of life four years later in a nationally representative sample of older adults. Data were derived from the first (2005-2006) and second wave (2009) of the Israeli component of the Survey of Health Ageing and Retirement in Europe (SHARE; N = 344). Hope was measured by three items from the Hope   Scale, and quality of life was measured by the CASP-12 (Control, Autonomy, Self-Realization, and Pleasure). Multiple regression analyses were conducted. Grip strength at T1 predicted QoL in T2, but hope was not a significant predictor. Furthermore, hope moderated the effect of handgrip on QoL, such that the effect was weaker for higher levels of hope. As hypothesized, hope acted as a moderator, such that poor grip strength was associated with worse QoL for less hopeful older adults, but grip strength was not associated with QoL for more hopeful older adults. Findings are consistent with a theoretical conceptualization of hope as a buffer between physical challenges and negative outcomes like QoL. Encouraging a hopeful perspective could enhance QoL for older adults with decreased muscle strength.

  7. Memory-guided force output is associated with self-reported ADHD symptoms in young adults.

    Science.gov (United States)

    Neely, Kristina A; Chennavasin, Amanda P; Yoder, Arie; Williams, Genevieve K R; Loken, Eric; Huang-Pollock, Cynthia L

    2016-11-01

    Attention-deficit/hyperactivity disorder (ADHD) is the most commonly diagnosed mental health disorder in childhood and persists into adulthood in up to 65 % of cases. ADHD is associated with adverse outcomes such as the ability to gain and maintain employment and is associated with an increased risk for substance abuse obesity workplace injuries and traffic accidents A majority of diagnosed children have motor deficits; however, few studies have examined motor deficits in young adults. This study provides a novel examination of visuomotor control of grip force in young adults with and without ADHD. Participants were instructed to maintain force production over a 20-second trial with and without real-time visual feedback about their performance. The results demonstrated that when visual feedback was available, adults with ADHD produced slightly higher grip force than controls. However, when visual feedback was removed, adults with ADHD had a faster rate of decay of force, which was associated with ADHD symptom severity and trait impulsivity. These findings suggest that there may be important differences in the way that adults with ADHD integrate visual feedback during continuous motor tasks. These may account for some of the motor impairments reported in children with ADHD. These deficits could result from (1) dysfunctional sensory motor integration and/or (2) deficits in short-term visuomotor memory.

  8. The contribution of prenatal environment and genetic factors to the association between birth weight and adult grip strength.

    Directory of Open Access Journals (Sweden)

    Charlotte L Ridgway

    2011-03-01

    Full Text Available Low birth weight has been associated with reduced hand grip strength, which is a marker of future physical function and disease risk. The aim of this study was to apply a twin pair approach, using both 'individual' data and 'within-pair' differences, to investigate the influence of birth weight on hand grip strength and whether this association may be mediated through fat free mass (FFM. Participants from the East Flanders Prospective Twin Survey were included if born without congenital abnormalities, birth weight >500 g and ≥22 weeks of gestation. Follow up in adulthood (age: 18-34 year, included anthropometric measures and hand grip (n = 783 individuals, n = 326 same-sex twin pairs. Birth weight was positively associated with hand grip strength (β = 2.60 kg, 95% CI 1.52, 3.67, p<0.001 and FFM (β = 4.2, 95% CI 3.16, 5.24, p<0.001, adjusted for gestational age, sex and adult age. Using 'within-pair' analyses, the birth weight hand grip association was significant in DZ men only (β = 5.82, 95% CI 0.67, 10.97, p = 0.028, which was attenuated following adjustment for FFM. Within-pair birth weight FFM associations were most pronounced in DZ men (β = 11.20, 95% CI 7.18, 15.22, p<0.001. Our 'individual' analyses show that higher birth weight is associated with greater adult hand grip strength, which is mediated through greater adult FFM. The 'within-pair' analyses confirm this observation and furthermore show that, particularly in men, genetic factors may in part explain this association, as birth weight differences in DZ men result in greater differences in adult strength and FFM.

  9. The effects of cold immersion and hand protection on grip strength.

    Science.gov (United States)

    Vincent, M J; Tipton, M J

    1988-08-01

    The maximal voluntary grip strength (MVGS) of male volunteers was examined following a series of five intermittent 2 min cold water (5 degrees C) immersions of the unprotected hand or forearm. MVGS changes due to wearing a protective glove were also investigated. The surface electrical activity over the hand flexor muscles was recorded, as was the skin temperature of the hand and forearm. MVGS decreased significantly (p less than 0.01) following hand immersions (16%) and forearm immersion (13%). The majority of these reductions occurred during the first 2-min period of immersion. The effect of wearing a glove after unprotected hand cooling also produced significant (p less than 0.01) MVGS reductions which averaged 14%. These reductions were in addition to those caused by hand cooling. We conclude that both hand and forearm protection are important for the maintenance of hand-grip strength following cold water immersion.

  10. A Monte Carlo-tuned model of the flow in the NorthGRIP area

    DEFF Research Database (Denmark)

    Grinsted, Aslak; Dahl-Jensen, Dorthe

    2002-01-01

    The North Greenland Icecore Project (NorthGRIP) drill site was chosen in order to obtain a good Eemian record. At the present depth, 3001m, the Eemian interstadial has yet to be seen. Clearly the flow in this area is poorly understood and needs further investigation. After a review of specific...... no Eemian is observed is a high basal melt rate (2.7mm/a). The melting is a consequence of a higher geothermal heat flux than the expected 51mW/m^2 of the Precambrian shield. From our analyses it is concluded that the geothermal heat flux at NorthGRIP is 98mW/m^2.The high basalmelt rate also gives rise...

  11. Finger pad friction and its role in grip and touch

    Science.gov (United States)

    Adams, Michael J.; Johnson, Simon A.; Lefèvre, Philippe; Lévesque, Vincent; Hayward, Vincent; André, Thibaut; Thonnard, Jean-Louis

    2013-01-01

    Many aspects of both grip function and tactile perception depend on complex frictional interactions occurring in the contact zone of the finger pad, which is the subject of the current review. While it is well established that friction plays a crucial role in grip function, its exact contribution for discriminatory touch involving the sliding of a finger pad is more elusive. For texture discrimination, it is clear that vibrotaction plays an important role in the discriminatory mechanisms. Among other factors, friction impacts the nature of the vibrations generated by the relative movement of the fingertip skin against a probed object. Friction also has a major influence on the perceived tactile pleasantness of a surface. The contact mechanics of a finger pad is governed by the fingerprint ridges and the sweat that is exuded from pores located on these ridges. Counterintuitively, the coefficient of friction can increase by an order of magnitude in a period of tens of seconds when in contact with an impermeably smooth surface, such as glass. In contrast, the value will decrease for a porous surface, such as paper. The increase in friction is attributed to an occlusion mechanism and can be described by first-order kinetics. Surprisingly, the sensitivity of the coefficient of friction to the normal load and sliding velocity is comparatively of second order, yet these dependencies provide the main basis of theoretical models which, to-date, largely ignore the time evolution of the frictional dynamics. One well-known effect on taction is the possibility of inducing stick–slip if the friction decreases with increasing sliding velocity. Moreover, the initial slip of a finger pad occurs by the propagation of an annulus of failure from the perimeter of the contact zone and this phenomenon could be important in tactile perception and grip function. PMID:23256185

  12. Finger pad friction and its role in grip and touch.

    Science.gov (United States)

    Adams, Michael J; Johnson, Simon A; Lefèvre, Philippe; Lévesque, Vincent; Hayward, Vincent; André, Thibaut; Thonnard, Jean-Louis

    2013-03-06

    Many aspects of both grip function and tactile perception depend on complex frictional interactions occurring in the contact zone of the finger pad, which is the subject of the current review. While it is well established that friction plays a crucial role in grip function, its exact contribution for discriminatory touch involving the sliding of a finger pad is more elusive. For texture discrimination, it is clear that vibrotaction plays an important role in the discriminatory mechanisms. Among other factors, friction impacts the nature of the vibrations generated by the relative movement of the fingertip skin against a probed object. Friction also has a major influence on the perceived tactile pleasantness of a surface. The contact mechanics of a finger pad is governed by the fingerprint ridges and the sweat that is exuded from pores located on these ridges. Counterintuitively, the coefficient of friction can increase by an order of magnitude in a period of tens of seconds when in contact with an impermeably smooth surface, such as glass. In contrast, the value will decrease for a porous surface, such as paper. The increase in friction is attributed to an occlusion mechanism and can be described by first-order kinetics. Surprisingly, the sensitivity of the coefficient of friction to the normal load and sliding velocity is comparatively of second order, yet these dependencies provide the main basis of theoretical models which, to-date, largely ignore the time evolution of the frictional dynamics. One well-known effect on taction is the possibility of inducing stick-slip if the friction decreases with increasing sliding velocity. Moreover, the initial slip of a finger pad occurs by the propagation of an annulus of failure from the perimeter of the contact zone and this phenomenon could be important in tactile perception and grip function.

  13. Criterion-Referenced Values of Grip Strength and Usual Gait Speed Using Instrumental Activities of Daily Living Disability as the Criterion.

    Science.gov (United States)

    Lee, Meng-Chih; Hsu, Chih-Cheng; Tsai, Yi-Fen; Chen, Ching-Yu; Lin, Cheng-Chieh; Wang, Ching-Yi

    Current evidence suggests that grip strength and usual gait speed (UGS) are important predictors of instrumental activities of daily living (IADL) disability. Knowing the optimum cut points of these tests for discriminating people with and without IADL disability could help clinicians or researchers to better interpret the test results and make medical decisions. The purpose of this study was to determine the cutoff values of grip strength and UGS for best discriminating community-dwelling older adults with and without IADL disability, separately for men and women, and to investigate their association with IADL disability. We conducted secondary data analysis on a national dataset collected in the Sarcopenia and Translational Aging Research in Taiwan (START). The data used in this study consisted of health data of 2420 community-dwelling older adults 65 years and older with no history of stroke and with complete data. IADL disability was defined as at least 1 IADL item scored as "need help" or "unable to perform." Receiver operating characteristics analysis was used to estimate the optimum grip strength and UGS cut points for best discriminating older adults with/without IADL disability. The association between each physical performance (grip strength and UGS) and IADL disability was assessed with odds ratios (ORs). With IADL disability as the criterion, the optimal cutoff values of grip strength were 28.7 kg for men and 16.0 kg for women, and those for UGS were 0.76 m/s for men and 0.66 m/s for women. The grip strength test showed satisfactory discriminant validity (area under the curve > 0.7) in men and a strong association with IADL disability (OR > 4). Our cut points using IADL disability as the criterion were close to those indicating frailty or sarcopenia. Our reported cutoffs can serve as criterion-referenced values, along with those previously determined using different indicators, and provide important landmarks on the performance continua of older adults

  14. Refuelling machine for nuclear reactor

    International Nuclear Information System (INIS)

    Shumyakin, E.P.; Sabir-de-Ribas, K.I.; Druzhinsky, I.A.; Shishov, G.P.; Andreichikov, B.I.

    1979-01-01

    The proposed manipulating means consists of housing, wherein a gripping means is arranged to grip a fuel assembly being transferred. The gripping means is coupled to a drive having a chain which is in contact with a sprocket mounted on an axle arranged in the sealed housing. The driving force of the drive is transmitted to the gripping means. The driving force is controlled by a force regulator mounted on the gripping means. The force regulator comprises two force tranducers mounted on the sealed housing, and a spring suspension member installed in the gripping means. Some clearance is allowed where the drive sprocket axle is secured in the walls of the sealed housing. The ends of the axle extend outside the sealed housing and are coupled to sensitive elements of the force transducers

  15. Corticomuscular coherence during hand gripping with DBS and medication in PD patients

    DEFF Research Database (Denmark)

    Sridharan, Kousik Sarathy; Højlund, Andreas; Johnsen, Erik Lisbjerg

    Deep brain stimulation (DBS) effectively alleviates the motor symptoms in Parkinson’s disease (PD) although its effect mechanism is still unclear. CMC is reduced in PD patients but restorable with medication, while DBS variably affects CMC in advanced PD patients. We recorded magnetoencephalography...... (MEG) from six PD patients performing hand gripping during DBS ON and medicated (levodopa, MED ON) conditions and from ten age-matched healthy controls. Participants performed isotonic contractions (hand gripping) with their right hand, and electromyography (EMG) was recorded from the extensor...... digitorum communis muscle with a belly-tendon montage. We calculated the mean-squared coherence between MEG and the rectified EMG signals. For each group and condition, we selected the maximum CMC value in the beta range (13-30 Hz) within the average of an a priori selection of nine left sensorimotor...

  16. Two-dimensional dopant profiling by electrostatic force microscopy using carbon nanotube modified cantilevers

    International Nuclear Information System (INIS)

    Chin, S.-C.; Chang, Y.-C.; Chang, C.-S.; Tsong, T T; Hsu, Chen-Chih; Wu, Chih-I; Lin, W-H; Woon, W-Y; Lin, L-T; Tao, H-J

    2008-01-01

    A two-dimensional (2D) dopant profiling technique is demonstrated in this work. We apply a unique cantilever probe in electrostatic force microscopy (EFM) modified by the attachment of a multiwalled carbon nanotube (MWNT). Furthermore, the tip apex of the MWNT was trimmed to the sharpness of a single-walled carbon nanotube (SWNT). This ultra-sharp MWNT tip helps us to resolve dopant features to within 10 nm in air, which approaches the resolution achieved by ultra-high vacuum scanning tunnelling microscopy (UHV STM). In this study, the CNT-probed EFM is used to profile 2D buried dopant distribution under a nano-scale device structure and shows the feasibility of device characterization for sub-45 nm complementary metal-oxide-semiconductor (CMOS) field-effect transistors

  17. Eyes, Grip and Gesture as Objective Indicators of Intentions and Attention

    DEFF Research Database (Denmark)

    Mortensen, Ditte Hvas

    This poster abstract presents the first part of a study concerning the use of information about gaze, grip and gesture to create non-command interaction. The experiment reported here seeks to establish the occurrence of patterns in nonverbal communication,  which may be used in an activity aware...

  18. Force and motion

    CERN Document Server

    Robertson, William C

    2002-01-01

    Intimidated by inertia? Frightened by forces? Mystified by Newton s law of motion? You re not alone and help is at hand. The stop Faking It! Series is perfect for science teachers, home-schoolers, parents wanting to help with homework all of you who need a jargon-free way to learn the background for teaching middle school physical science with confidence. With Bill Roberton as your friendly, able but somewhat irreverent guide, you will discover you CAN come to grips with the basics of force and motion. Combining easy-to-understand explanations with activities using commonly found equipment, this book will lead you through Newton s laws to the physics of space travel. The book is as entertaining as it is informative. Best of all, the author understands the needs of adults who want concrete examples, hands-on activities, clear language, diagrams and yes, a certain amount of empathy. Ideas For Use Newton's laws, and all of the other motion principles presented in this book, do a good job of helping us to underst...

  19. Development of Hand Grip Assistive Device Control System for Old People through Electromyography (EMG) Signal Acquisitions

    OpenAIRE

    Khamis Herman; Mohamaddan Shahrol; Komeda Takashi; Alias Aidil Azli; Tanjong Shirley Jonathan; Julai Norhuzaimin; Hashim Nurul ‘Izzati

    2017-01-01

    The hand grip assistive device is a glove to assist old people who suffer from hand weakness in their daily life activities. The device earlier control system only use simple on and off switch. This required old people to use both hand to activate the device. The new control system of the hand grip assistive device was developed to allow single hand operation for old people. New control system take advantages of electromyography (EMG) and flex sensor which was implemented to the device. It wa...

  20. Contact pressure measurement in hand tool evaluation studies

    NARCIS (Netherlands)

    Kuijt-Evers, L.F.M.; Bosch, T.

    2006-01-01

    In hand tool evaluation studies, several objective measurements are used. Grip force distribution and grip force are important as they give feedback about the force which has to be performed with the hand on the handle. A measurement technique -which is related to grip force measurement- is contact

  1. Polymer micro-grippers with an integrated force sensor for biological manipulation

    International Nuclear Information System (INIS)

    Mackay, R E; Le, H R; Clark, S; Williams, J A

    2013-01-01

    The development of a novel micro-system integrating SU-8 polymer micro-grippers with a tensile force sensor for handling and characterizing the mechanical properties of delicate biological materials, such as fibrils, is presented. The micro-grippers are actuated by the electro-thermal effect and have gripping forces comparable to the common ‘hot-and-cold-arm’ grippers. A robust finite element model was developed to investigate system performance and validated experimentally. A new micro-mechanical calibration method using a piezoelectric manipulator with a micro-force measurement system was successfully applied to test the structure. Both FEA simulation and micro-mechanical testing results indicated that the system could fulfil the requirements for micro-object manipulation within a biological environment. (paper)

  2. Effects of hyperthyroidism on hand grip strength and function

    OpenAIRE

    Esra Erkol İnal, MD; Alparslan Bayram Çarlı, MD; Sultan Çanak, MD; Oğuzhan Aksu, MD; Banu Kale Köroğlu, MD; Serpil Savaş

    2015-01-01

    Hyperthyroidism is a pathologic condition in which the body is exposed to excessive amounts of circulating thyroid hormones. Skeletal muscle is one of the major target organs of thyroid hormones. We evaluated hand grip strength and function in patients with overt hyperthyroidism. Fifty-one patients newly diagnosed with hyperthyroidism and 44 healthy controls participated in this study. Age, height, weight, and dominant hand of all participants were recorded. The diagnosis of hyperthyroidism w...

  3. Comparison of Initial Effect of Taping Techniqe and Counterforce Brace on Pain and Grip Strength of Patients with Lateral Epicondylitis

    Directory of Open Access Journals (Sweden)

    Ali Reza Shamsoddini

    2006-04-01

    Full Text Available Objective: In patients with lateral epicondylitis present of pain and decrease of grip strength are essential problems. Use of splint have major rule in treatment these patients that causes relief of pain and increase of grip strength. Both taping technique and counterforce brace are two methods of treatments of lateral epicondylitis patients but we were not sure which method could be more useful and Answer of this question is magor aim of this study. Materials & Methods: This study is a Quasi experimental. We selected 30 patients between 30-55 years conveniently and divided them in two groups simple randomized.  Results: In grip strength test, the average difference between two methods was t = 1/92 which showed there is not significant. So, there isn't any difference between two methods on grip strength. In assessment of pain, we tested patients in two positions: first patient's hand was in comfort position, second in which when wrist of hand was in extension position. In both of position, that average difference between two methods (first t = 3/78 and secondary t = 3/2 found to be significant. Choose of method in such treatment is considered to be important. Conclusion: taping technique is more effective than counterforce brace to relief of pain of patients with lateral epicondylitis, but in grip strength no difference between two methods.

  4. Hand grip strength and maximum peak expiratory flow: determinants of bone mineral density of adolescent students.

    Science.gov (United States)

    Cossio-Bolaños, Marco; Lee-Andruske, Cynthia; de Arruda, Miguel; Luarte-Rocha, Cristian; Almonacid-Fierro, Alejandro; Gómez-Campos, Rossana

    2018-03-02

    Maintaining and building healthy bones during the lifetime requires a complicated interaction between a number of physiological and lifestyle factors. Our goal of this study was to analyze the association between hand grip strength and the maximum peak expiratory flow with bone mineral density and content in adolescent students. The research team studied 1427 adolescent students of both sexes (750 males and 677 females) between the ages of 11.0 and 18.9 years in the Maule Region of Talca (Chile). Weight, standing height, sitting height, hand grip strength (HGS), and maximum peak expiratory flow (PEF) were measured. Furthermore, bone mineral density (BMD) and total body bone mineral content (BMC) were determined by using the Dual-Energy X-Ray Absorptiometry (DXA). Hand grip strength and PEF were categorized in tertiles (lowest, middle, and highest). Linear regression was performed in steps to analyze the relationship between the variables. Differences between categories were determined through ANOVA. In males, the hand grip strength explained 18-19% of the BMD and 20-23% of the BMC. For the females, the percentage of variation occurred between 12 and 13% of the BMD and 17-18% of the BMC. The variation of PEF for the males was observed as 33% of the BMD and 36% of the BMC. For the females, both the BMD and BMC showed a variation of 19%. The HGS and PEF were divided into three categories (lowest, middle, and highest). In both cases, significant differences occurred in bone density health between the three categories. In conclusion, the HGS and the PEF related positively to the bone density health of both sexes of adolescent students. The adolescents with poor values for hand grip strength and expiratory flow showed reduced values of BMD and BMC for the total body. Furthermore, the PEF had a greater influence on bone density health with respect to the HGS of the adolescents of both sexes.

  5. The GRIP method for collaborative roadmapping workshops

    DEFF Research Database (Denmark)

    Piirainen, Kalle

    2015-01-01

    Technology roadmapping is a well-known tool for technology management, but practical advice for facilitating collaborative roadmapping workshops is relatively scarce. To cater for this need, we have designed a method for collaborative roadmapping, dubbed the GRIP method, for facilitating group work...... in TRM workshops. The design is based on establish best practices in facilitation and our experiences with the method suggest it is a feasible tool for technology managers. The benefits of the method are that it enables engaging a diverse group of individuals to the roadmapping process effectively even...... during a short workshop session and facilitates shared understanding on the technology management issues....

  6. Physiological, Nutritional and Performance Profiles of Brazilian Jiu-Jitsu Athletes

    OpenAIRE

    Andreato, Leonardo V; Santos, Jonatas FS; Esteves, Jo?o VDC; Panissa, Valeria LG; Julio, Ursula F; Franchini, Emerson

    2016-01-01

    Abstract This study analysed the physiological, nutritional and performance profiles of athletes practicing Brazilian jiu-jitsu. To this end, 15 athletes that practiced Brazilian jiu-jitsu (aged: 28 ? 5 years; 8 brown belts and 7 black belts; training experience: 11 ? 4 years) underwent anthropometric measurements (body composition and somatotype), dietary evaluation (24 h recall) and physical fitness tests (movement time, dynamometer handgrip, kimono grip strength, vertical jump and sit-and-...

  7. Characterization of the spontaneous and gripping-induced immobility episodes on taiep rats.

    Science.gov (United States)

    Cortés, Ma Del Carmen; Gavito, Berenice; Ita, Martha L; Valencia, Jaime; Eguibar, José R

    2005-11-01

    In 1989, we described a new autosomic-recessive myelin-mutant rat that develops a progressive motor syndrome characterized by tremor, ataxia, immobility episodes (IEs), epilepsy, and paralysis. taiep is the acronym of these symptoms. The rat developed a hypomyelination, followed by demyelination. At an age of 7-8 months, taiep rats developed IEs, characterized electroencephalographically by REM sleep-like cortical activity. In our study, we analyzed the ontogeny of gripping-induced IEs between 5 and 18 months, their dependence to light-dark changes, sexual dimorphism, and susceptibility to mild stress. Our results showed that IEs start at an age of 6.5 months, with a peak frequency between 8.5 and 9.5 months. IEs have two peaks, one in the morning (0800-1000 h) and a second peak in the middle of the night (2300-0100 h). Spontaneous IEs showed an even distribution with a mean of 3 IEs every 2 h. IEs are sexually dimorphic being more common in male rats. The IEs can be induced by gripping the rat by the tail or the thorax, but most of the IEs were produced by gripping the tail. Mild stress produced by i.p. injection of physiological saline significantly decreased IEs. These results suggested that IEs are dependent on several biological variables, which are caused by hypomyelination, followed by demyelization, which causes alterations in the brainstem and hypothalamic mechanisms responsible for the sleep-wake cycle regulation, producing emergence of REM sleep-like behavior during awake periods. (c) 2005 Wiley-Liss, Inc.

  8. Association of the AMPA receptor-related postsynaptic density proteins GRIP and ABP with subsets of glutamate-sensitive neurons in the rat retina.

    Science.gov (United States)

    Gábriel, Robert; de Souza, Sunita; Ziff, Edward B; Witkovsky, Paul

    2002-07-22

    We used specific antibodies against two postsynaptic density proteins, GRIP (glutamate receptor interacting protein) and ABP (AMPA receptor-binding protein), to study their distribution in the rat retina. In the central nervous system, it has been shown that both proteins bind strongly to the AMPA glutamate receptor (GluR) 2/3 subunits, but not other GluRs, through a set of three PDZ domains. Western blots detected a single GRIP protein that was virtually identical in retina and brain, whereas retinal ABP corresponded to only one of three ABP peptides found in brain. The retinal distributions of GluR2/3, GRIP, and ABP immunoreactivity (IR) were similar but not identical. GluR2/3 immunoreactivity (IR) was abundant in both plexiform layers and in large perikarya. ABP IR was concentrated in large perikarya but was sparse in the plexiform layers, whereas GRIP IR was relatively more abundant in the plexiform layers than in perikarya. Immunolabel for these three antibodies consisted of puncta ABP IR was examined by double labeling subclasses of retinal neuron with characteristic marker proteins, e.g., calbindin. GRIP, ABP, and GluR2/3 IR were detected in horizontal cells, dopaminergic and glycinergic AII amacrine cells and large ganglion cells. Immunolabel was absent in rod bipolar and weak or absent in cholinergic amacrine cells. By using the tyramide method of signal amplification, a colocalization of GluR2/3 was found with either GRIP or ABP in horizontal cell terminals, and perikarya of amacrine and ganglion cells. Our results show that ABP and GRIP colocalize with GluR2/3 in particular subsets of retinal neuron, as was previously established for certain neurons in the brain. Copyright 2002 Wiley-Liss, Inc.

  9. Atomic force microscopy for the determination of refractive index profiles of optical fibres and waveguides: a quantitative study

    International Nuclear Information System (INIS)

    Huntington, S.T.; Mulvaney, P.; Roberts, K.A.

    1997-01-01

    The use of preferential etching and atomic force microscopy to measure refractive index profiles of optical fibres is investigated. Both the etch rate and the position of lateral features are shown to be independent of etch time. An elliptical core fibre has been studied and the resultant profile found to be in qualitative agreement with the preform index profile. It is shown, however, that the ellipticity of the core has changed during the drawing process. The method has been extended to fluorine and germanium doped planar waveguides and the results correlated with the fabrication process

  10. Força de preensão palmar e pinça digital em diferentes grupos de pilotos da Academia da Força Aérea brasileira Grip and pinch strength among different groups of Brazilian Air Force pilots

    Directory of Open Access Journals (Sweden)

    Gláucia Helena Gonçalves

    2010-06-01

    Full Text Available Pilotos da Academia de Força Aérea (AFA brasileira, durante vôos, realizam movimentos com grande solicitação da musculatura da mão que comanda o manche, o que pode modificar a força muscular. Este estudo teve por objetivo analisar as forças musculares isométricas de preensão palmar e pinças polpa-a-polpa, trípode e lateral de três grupos de pilotos da AFA. Foram avaliados 15 pilotos da Esquadrilha da Fumaça (EDA, 16 instrutores de vôo (PI e 6 pilotos em treinamento (PT, todos do sexo masculino. Para a avaliação, o posicionamento corporal dos pilotos seguiu a padronização da Sociedade Americana de Terapeutas da Mão e a ordem dos movimentos analisados foi predefinida, evitando fadiga muscular. A força muscular isométrica máxima foi coletada em uma contração sustentada por 6 segundos. Os resultados mostram diferenças significativas na preensão, com superioridade das mãos dominantes em relação às não-dominantes em todos os grupos, tendo ainda o grupo EDA obtido valores significativamente superiores em relação aos demais. Nas medidas da pinça trípode, o grupo EDA apresentou significativos valores superiores aos do grupo PT, sendo encontrados valores das mãos dominantes superiores aos das não-dominantes nos grupos EDA e PI. Conclui-se que o treino específico da musculatura da mão durante o vôo, a especificidade e o período de treinamento interferem na força muscular isométrica da mão.Pilots from Brazilian Air Force Academy (AFA perform strentgth- and accuracy-demanding hand movements, which may modify muscle strength. The aim of this study was to analyse hand isometric strength of grip and pulp-to-pulp, tripode and lateral pinch in three groups of male AFA pilots: ADS (Air Demonstration Squadron, n=15; IP (instructor pilots, n=16; and TP (training pilots, n=6. Pilots body positioning during tests followed the standards of the American Society of Hand Therapists; the sequence of assessed movements was

  11. Correlation of force control with regional spinal DTI in patients with cervical spondylosis without signs of spinal cord injury on conventional MRI

    International Nuclear Information System (INIS)

    Lindberg, Paavel G.; Sanchez, Katherine; Rannou, Francois; Poiraudeau, Serge; Ozcan, Fidan; Feydy, Antoine; Maier, Marc A.

    2016-01-01

    The aim of this study was to investigate spinal cord structure in patients with cervical spondylosis where conventional MRI fails to reveal spinal cord damage. We performed a cross-sectional study of patients with cervical spondylosis without conventional MRI findings of spinal cord damage and healthy controls. Subjects were studied using spinal diffusion tensor imaging (DTI), precision grip and foot force-tracking tasks, and a clinical examination including assessment of neurological signs. A regional analysis of lateral and medial spinal white matter across multiple cervical levels (C1-C5) was performed. DTI revealed reduced fractional anisotropy (FA) and increased radial diffusivity (RD) in the lateral spinal cord at the level of greatest compression (lowest Pavlov ratio) in patients (p < 0.05). Patients with spondylosis had greater error and longer release duration in both grip and foot force-tracking. Similar spinal cord deficits were present in patients without neurological signs. Increased error in grip and foot tracking (low accuracy) correlated with increased RD in the lateral spinal cord at the level of greatest compression (p ≤ 0.01). Spinal DTI can detect subtle spinal cord damage of functional relevance in cervical spondylosis, even in patients without signs on conventional T2-imaging and without neurological signs. (orig.)

  12. Correlation of force control with regional spinal DTI in patients with cervical spondylosis without signs of spinal cord injury on conventional MRI

    Energy Technology Data Exchange (ETDEWEB)

    Lindberg, Paavel G. [Universite Paris Descartes, Sorbonne Paris Cite, FR 3636 Neurosciences, Paris (France); Centre de Psychiatrie et Neurosciences, Inserm U894, Paris (France); Universite Paris Descartes, Sorbonne Paris Cite, Paris (France); Universite Paris Descartes, Service de Radiologie B, APHP, CHU Cochin, Faculte de Medecine, Paris (France); Sanchez, Katherine; Rannou, Francois; Poiraudeau, Serge [Universite Paris Descartes, Sorbonne Paris Cite, Paris (France); Service de Medecine Physique et de Readaptation, APHP, CHU Cochin, Paris (France); INSERM U1153 Epidemiologie Clinique des Maladies Osteo-Articulaires, Paris (France); Ozcan, Fidan [Universite Paris Descartes, Sorbonne Paris Cite, FR 3636 Neurosciences, Paris (France); Feydy, Antoine [Universite Paris Descartes, Sorbonne Paris Cite, FR 3636 Neurosciences, Paris (France); Universite Paris Descartes, Sorbonne Paris Cite, Paris (France); Universite Paris Descartes, Service de Radiologie B, APHP, CHU Cochin, Faculte de Medecine, Paris (France); Maier, Marc A. [Universite Paris Descartes, Sorbonne Paris Cite, FR 3636 Neurosciences, Paris (France); Universite Paris Descartes, Sorbonne Paris Cite, Paris (France); Universite Paris Diderot, Sorbonne Paris Cite, Paris (France)

    2016-03-15

    The aim of this study was to investigate spinal cord structure in patients with cervical spondylosis where conventional MRI fails to reveal spinal cord damage. We performed a cross-sectional study of patients with cervical spondylosis without conventional MRI findings of spinal cord damage and healthy controls. Subjects were studied using spinal diffusion tensor imaging (DTI), precision grip and foot force-tracking tasks, and a clinical examination including assessment of neurological signs. A regional analysis of lateral and medial spinal white matter across multiple cervical levels (C1-C5) was performed. DTI revealed reduced fractional anisotropy (FA) and increased radial diffusivity (RD) in the lateral spinal cord at the level of greatest compression (lowest Pavlov ratio) in patients (p < 0.05). Patients with spondylosis had greater error and longer release duration in both grip and foot force-tracking. Similar spinal cord deficits were present in patients without neurological signs. Increased error in grip and foot tracking (low accuracy) correlated with increased RD in the lateral spinal cord at the level of greatest compression (p ≤ 0.01). Spinal DTI can detect subtle spinal cord damage of functional relevance in cervical spondylosis, even in patients without signs on conventional T2-imaging and without neurological signs. (orig.)

  13. Modified forelimb grip strength test detects aging-associated physiological decline in skeletal muscle function in male mice.

    Science.gov (United States)

    Takeshita, Hikari; Yamamoto, Koichi; Nozato, Satoko; Inagaki, Tadakatsu; Tsuchimochi, Hirotsugu; Shirai, Mikiyasu; Yamamoto, Ryohei; Imaizumi, Yuki; Hongyo, Kazuhiro; Yokoyama, Serina; Takeda, Masao; Oguro, Ryosuke; Takami, Yoichi; Itoh, Norihisa; Takeya, Yasushi; Sugimoto, Ken; Fukada, So-Ichiro; Rakugi, Hiromi

    2017-02-08

    The conventional forelimb grip strength test is a widely used method to assess skeletal muscle function in rodents; in this study, we modified this method to improve its variability and consistency. The modified test had lower variability among trials and days than the conventional test in young C57BL6 mice, especially by improving the variabilities in male. The modified test was more sensitive than the conventional test to detect a difference in motor function between female and male mice, or between young and old male mice. When the modified test was performed on male mice during the aging process, reduction of grip strength manifested between 18 and 24 months of age at the group level and at the individual level. The modified test was similar to the conventional test in detecting skeletal muscle dysfunction in young male dystrophic mice. Thus, the modified forelimb grip strength test, with its improved validity and reliability may be an ideal substitute for the conventional method.

  14. Multiple fuel rod gripper

    International Nuclear Information System (INIS)

    Shields, E.P.

    1987-01-01

    An apparatus is described for gripping an array of rods comprising: (a) gripping members grippingly engageable with the rods, each of which has a hollow portion terminating in an open end for receiving the end of one of the rods; (b) a closing means for causing the hollow portion of each of the gripping members to apply substantially the same gripping force onto the end of its respective rod, including (i) a locking plate having a plurality of tapered holes registrable with the array of rods, wherein the exterior of each of the gripping members is tapered and nested within one of the tapered holes, (ii) a withdrawing means having a hydraulic plunger operatively connected to each of the gripping members for applying a substantially identical withdrawing force on each of the gripping members, whereby the hollow portion of each of the gripping members applies substantially the same gripping force on its respective rod, and (c) means for detecting whether each of the gripping members has grippingly engaged its respective rod

  15. Hand grips strength effect on motor function in human brain using fMRI: a pilot study

    International Nuclear Information System (INIS)

    Ismail, S S; Mohamad, M; Syazarina, S O; Nafisah, W Y

    2014-01-01

    Several methods of motor tasks for fMRI scanning have been evolving from simple to more complex tasks. Motor tasks on upper extremity were applied in order to excite the increscent of motor activation on contralesional and ipsilateral hemispheres in brain. The main objective of this study is to study the different conditions for motor tasks on upper extremity that affected the brain activation. Ten healthy right handed with normal vision (3 male and 7 female, age range=20-30 years, mean=24.6 years, SD=2.21) participated in this study. Prior to the scanning, participants were trained on hand grip tasks using rubber ball and pressure gauge tool outside the scanner. During fMRI session, a block design with 30-s task blocks and alternating 30-s rest periods was employed while participants viewed a computer screen via a back projection-mirror system and instructed to follow the instruction by gripping their hand with normal and strong grips using a rubber ball. Statistical Parametric mapping (SPM8) software was used to determine the brain activation. Both tasks activated the primary motor (M1), supplementary motor area (SMA), dorsal and ventral of premotor cortex area (PMA) in left hemisphere while in right hemisphere the area of primary motor (M1) somatosensory was activated. However, the comparison between both tasks revealed that the strong hand grip showed the higher activation at M1, PMA and SMA on left hemisphere and also the area of SMA on right hemisphere. Both conditions of motor tasks could provide insights the functional organization on human brain

  16. Hand grips strength effect on motor function in human brain using fMRI: a pilot study

    Science.gov (United States)

    Ismail, S. S.; Mohamad, M.; Syazarina, S. O.; Nafisah, W. Y.

    2014-11-01

    Several methods of motor tasks for fMRI scanning have been evolving from simple to more complex tasks. Motor tasks on upper extremity were applied in order to excite the increscent of motor activation on contralesional and ipsilateral hemispheres in brain. The main objective of this study is to study the different conditions for motor tasks on upper extremity that affected the brain activation. Ten healthy right handed with normal vision (3 male and 7 female, age range=20-30 years, mean=24.6 years, SD=2.21) participated in this study. Prior to the scanning, participants were trained on hand grip tasks using rubber ball and pressure gauge tool outside the scanner. During fMRI session, a block design with 30-s task blocks and alternating 30-s rest periods was employed while participants viewed a computer screen via a back projection-mirror system and instructed to follow the instruction by gripping their hand with normal and strong grips using a rubber ball. Statistical Parametric mapping (SPM8) software was used to determine the brain activation. Both tasks activated the primary motor (M1), supplementary motor area (SMA), dorsal and ventral of premotor cortex area (PMA) in left hemisphere while in right hemisphere the area of primary motor (M1) somatosensory was activated. However, the comparison between both tasks revealed that the strong hand grip showed the higher activation at M1, PMA and SMA on left hemisphere and also the area of SMA on right hemisphere. Both conditions of motor tasks could provide insights the functional organization on human brain.

  17. Physical function, grip strength and frailty in people living with HIV in sub-Saharan Africa: systematic review.

    Science.gov (United States)

    Bernard, Charlotte; Dabis, François; de Rekeneire, Nathalie

    2017-05-01

    To present the current knowledge on physical function, grip strength and frailty in HIV-infected patients living in sub-Saharan Africa, where the phenomenon is largely underestimated. A systematic search was conducted on MEDLINE, Scopus and African Index Medicus. We reviewed articles on sub-Saharan African people living with HIV (PLHIV) >18 years old, published until November 2016. Of 537 articles, 12 were conducted in six African countries and included in this review. Five articles reported information on functional limitation and one on disability. Two of these five articles reported functional limitation (low gait speed) in PLHIV. Disability was observed in 27% and 3% of PLHIV living in rural and urban places, respectively. Two of three studies reporting grip strength reported lower grip strength (nearly 4 kg) in PLHIV in comparison with uninfected patients. One study reported that PLHIV were more likely to be frail than HIV-uninfected individuals (19.4% vs. 13.3%), whereas another reported no statistical difference. Decline in physical function, grip strength and frailty are now part of the burden of PLHIV living in SSA countries, but current data are insufficient to characterise the real public health dimension of these impairments. Further studies are needed to depict this major public health challenge. As this is likely to contribute to a significant burden on the African healthcare systems and human resources in the near future, a holistic care approach should be developed to inform guidelines. © 2017 John Wiley & Sons Ltd.

  18. Manipulating Microrobots Using Balanced Magnetic and Buoyancy Forces

    Directory of Open Access Journals (Sweden)

    Lin Feng

    2018-01-01

    Full Text Available We present a novel method for the three-dimensional (3D control of microrobots within a microfluidic chip. The microrobot body contains a hollow space, producing buoyancy that allows it to float in a microfluidic environment. The robot moves in the z direction by balancing magnetic and buoyancy forces. In coordination with the motion of stages in the xy plane, we achieved 3D microrobot control. A microgripper designed to grasp micron-scale objects was attached to the front of the robot, allowing it to hold and deliver micro-objects in three dimensions. The microrobot had four degrees of freedom and generated micronewton-order forces. We demonstrate the microrobot’s utility in an experiment in which it grips a 200 μm particle and delivers it in a 3D space.

  19. Electrical conductivity measurements from the GISP2 and GRIP Greenland ice cores

    DEFF Research Database (Denmark)

    Dahl-Jensen, Dorthe; Clausen, Henrik Brink; Taylor, K. C.

    1993-01-01

    . Here we present electrical conductivity records for the Greenland Ice Sheet Project 2 (GISP2) and Greenland Ice-core Project (GRIP) ice cores, drilled 28 km apart to enable direct comparison of the results. The upper parts of both records are consistent with previous evidence from other Greenland cores...

  20. The FORCE Fitness Profile--Adding a Measure of Health-Related Fitness to the Canadian Armed Forces Operational Fitness Evaluation.

    Science.gov (United States)

    Gagnon, Patrick; Spivock, Michael; Reilly, Tara; Mattie, Paige; Stockbrugger, Barry

    2015-11-01

    In 2013, the Canadian Armed Forces (CAF) implemented the Fitness for Operational Requirements of Canadian Armed Forces Employment (FORCE), a field expedient fitness test designed to predict the physical requirements of completing common military tasks. Given that attaining this minimal physical fitness standard may not represent a challenge to some personnel, a fitness incentive program was requested by the chain of command to recognize and reward fitness over and above the minimal standard. At the same time, it was determined that the CAF would benefit from a measure of general health-related fitness, in addition to this measure of operational fitness. The resulting incentive program structure is based on gender and 8 age categories. The results on the 4 elements of the FORCE evaluation were converted to a point scale from which normative scores were derived, where the median score corresponds to the bronze level, and silver, gold, and platinum correspond to a score which is 1, 2, and 3 SDs above this median, respectively. A suite of rewards including merit board point toward promotions and recognition on the uniform and material rewards was developed. A separate group rewards program was also tabled, to recognize achievements in fitness at the unit level. For general fitness, oxygen capacity was derived from FORCE evaluation results and combined with a measure of abdominal circumference. Fitness categories were determined based on relative risks of mortality and morbidity for each age and gender group. Pilot testing of this entire program was performed with 624 participants to assess participants' reactions to the enhanced test, and also to verify logistical aspects of the electronic data capture, calculation, and transfer system. The newly dubbed fitness profile program was subsequently approved by the senior leadership of the CAF and is scheduled to begin a phased implementation in June 2015.

  1. NONLINEAR FORCE PROFILE USED TO INCREASE THE PERFORMANCE OF A HAPTIC USER INTERFACE FOR TELEOPERATING A ROBOTIC HAND

    Energy Technology Data Exchange (ETDEWEB)

    Anthony L. Crawford

    2012-07-01

    MODIFIED PAPER TITLE AND ABSTRACT DUE TO SLIGHTLY MODIFIED SCOPE: TITLE: Nonlinear Force Profile Used to Increase the Performance of a Haptic User Interface for Teleoperating a Robotic Hand Natural movements and force feedback are important elements in using teleoperated equipment if complex and speedy manipulation tasks are to be accomplished in hazardous environments, such as hot cells, glove boxes, decommissioning, explosives disarmament, and space. The research associated with this paper hypothesizes that a user interface and complementary radiation compatible robotic hand that integrates the human hand’s anthropometric properties, speed capability, nonlinear strength profile, reduction of active degrees of freedom during the transition from manipulation to grasping, and just noticeable difference force sensation characteristics will enhance a user’s teleoperation performance. The main contribution of this research is in that a system that concisely integrates all these factors has yet to be developed and furthermore has yet to be applied to a hazardous environment as those referenced above. In fact, the most prominent slave manipulator teleoperation technology in use today is based on a design patented in 1945 (Patent 2632574) [1]. The robotic hand/user interface systems of similar function as the one being developed in this research limit their design input requirements in the best case to only complementing the hand’s anthropometric properties, speed capability, and linearly scaled force application relationship (e.g. robotic force is a constant, 4 times that of the user). In this paper a nonlinear relationship between the force experienced between the user interface and the robotic hand was devised based on property differences of manipulation and grasping activities as they pertain to the human hand. The results show that such a relationship when subjected to a manipulation task and grasping task produces increased performance compared to the

  2. The Effect of Two Different Hand Exercises on Grip Strength, Forearm Circumference, and Vascular Maturation in Patients Who Underwent Arteriovenous Fistula Surgery

    Science.gov (United States)

    Kong, Sangwon; Lee, Kyung Soo; Kim, Junho

    2014-01-01

    Objective To compare the effect of two different hand exercises on hand strength and vascular maturation in patients who underwent arteriovenous fistula surgery. Methods We recruited 18 patients who had chronic kidney disease and had undergone arteriovenous fistula surgery for hemodialysis. After the surgery, 10 subjects performed hand-squeezing exercise with GD Grip, and other 8 subjects used Soft Ball. The subjects continued the exercises for 4 weeks. The hand grip strength, pinch strength (tip, palmar and lateral pinch), and forearm circumference of the subjects were assessed before and after the hand-squeezing exercise. The cephalic vein size, blood flow velocity and volume were also measured by ultrasonography in the operated limb. Results All of the 3 types of pinch strengths, grip strength, and forearm circumference were significantly increased in the group using GD Grip. Cephalic vein size and blood flow volume were also significantly increased. However, blood flow velocity showed no difference after the exercise. The group using Soft Ball showed a significant increase in the tip and lateral pinch strength and forearm circumference. The cephalic vein size and blood flow volume were also significantly increased. On comparing the effect of the two different hand exercises, hand-squeezing exercise with GD Grip had a significantly better effect on the tip and palmar pinch strength than hand-squeezing exercise with Soft Ball. The effect on cephalic vein size was not significantly different between the two groups. Conclusion The results showed that hand squeezing exercise with GD Grip was more effective in increasing the tip and palmar pinch strength compared to hand squeezing exercise with soft ball. PMID:25379494

  3. A Strain-Based Method to Detect Tires' Loss of Grip and Estimate Lateral Friction Coefficient from Experimental Data by Fuzzy Logic for Intelligent Tire Development.

    Science.gov (United States)

    Yunta, Jorge; Garcia-Pozuelo, Daniel; Diaz, Vicente; Olatunbosun, Oluremi

    2018-02-06

    Tires are a key sub-system of vehicles that have a big responsibility for comfort, fuel consumption and traffic safety. However, current tires are just passive rubber elements which do not contribute actively to improve the driving experience or vehicle safety. The lack of information from the tire during driving gives cause for developing an intelligent tire. Therefore, the aim of the intelligent tire is to monitor tire working conditions in real-time, providing useful information to other systems and becoming an active system. In this paper, tire tread deformation is measured to provide a strong experimental base with different experiments and test results by means of a tire fitted with sensors. Tests under different working conditions such as vertical load or slip angle have been carried out with an indoor tire test rig. The experimental data analysis shows the strong relation that exists between lateral force and the maximum tensile and compressive strain peaks when the tire is not working at the limit of grip. In the last section, an estimation system from experimental data has been developed and implemented in Simulink to show the potential of strain sensors for developing intelligent tire systems, obtaining as major results a signal to detect tire's loss of grip and estimations of the lateral friction coefficient.

  4. Cognitive-motor interference while grasping, lifting and holding objects.

    Directory of Open Access Journals (Sweden)

    Erwan Guillery

    Full Text Available In daily life, object manipulation is usually performed concurrently to the execution of cognitive tasks. The aim of the present study was to determine which aspects of precision grip require cognitive resources using a motor-cognitive dual-task paradigm. Eighteen healthy participants took part in the experiment, which comprised two conditions. In the first condition, participants performed a motor task without any concomitant cognitive task. They were instructed to grip, lift and hold an apparatus incorporating strain gauges allowing a continuous measurement of the force perpendicular to each contact surface (grip force, GF as well as the total tangential force applied on the object (load force, LF. In the second condition, participants performed the same motor task while concurrently performing a cognitive task consisting in a complex visual search combined with counting. In the dual-task condition, we found a significant increase in the duration of the preload phase (time between initial contact of the fingers with the apparatus and onset of the load force, as well as a significant increase of the grip force during the holding phase, indicating that the cognitive task interfered with the initial force scaling performed during the preload phase and the fine-tuning of grip force during the hold phase. These findings indicate that these aspects of precision grip require cognitive resources. In contrast, other aspects of the precision grip, such as the temporal coupling between grip and load forces, were not affected by the cognitive task, suggesting that they reflect more automatic processes. Taken together, our results suggest that assessing the dynamic and temporal parameters of precision grip in the context of a concurrent cognitive task may constitute a more ecological and better-suited tool to characterize motor dysfunction in patients.

  5. Repeated exposure to corticosterone increases depression-like behavior in two different versions of the forced swim test without altering nonspecific locomotor activity or muscle strength.

    Science.gov (United States)

    Marks, Wendie; Fournier, Neil M; Kalynchuk, Lisa E

    2009-08-04

    We have recently shown that repeated high dose injections of corticosterone (CORT) reliably increase depression-like behavior on a modified one-day version of the forced swim test. The main purpose of this experiment was to compare the effect of these CORT injections on our one-day version of the forced swim test and the more traditional two-day version of the test. A second purpose was to determine whether altered behavior in the forced swim test could be due to nonspecific changes in locomotor activity or muscle strength. Separate groups of rats received a high dose CORT injection (40 mg/kg) or a vehicle injection once per day for 21 consecutive days. Then, half the rats from each group were exposed to the traditional two-day forced swim test and the other half were exposed to our one-day forced swim test. After the forced swim testing, all the rats were tested in an open field and in a wire suspension grip strength test. The CORT injections significantly increased the time spent immobile and decreased the time spent swimming in both versions of the forced swim test. However, they had no significant effect on activity in the open field or grip strength in the wire suspension test. These results show that repeated CORT injections increase depression-like behavior regardless of the specific parameters of forced swim testing, and that these effects are independent of changes in locomotor activity or muscle strength.

  6. A single magnetic nanocomposite cilia force sensor

    KAUST Repository

    Alfadhel, Ahmed; Khan, Mohammed Asadullah; Cardoso, Susana; Kosel, Jü rgen

    2016-01-01

    The advancements in fields like robotics and medicine continuously require improvements of sensor devices and more engagement of cooperative sensing technologies. For example, instruments such as tweezers with sensitive force sensory heads could provide the ability to sense a variety of physical quantities in real time, such as the amount and direction of the force applied or the texture of the gripped object. Force sensors with such abilities could be great solutions toward the development of smart surgical tools. In this work, a unique force sensor that can be integrated at the tips of robotic arms or surgical tools is reported. The force sensor consists of a single bioinspired, permanent magnetic and highly elastic nanocomposite cilia integrated on a magnetic field sensing element. The nanocomposite is prepared from permanent magnetic nanowires incorporated into the highly elastic polydimethylsiloxane. We demonstrate the potential of this concept by performing several experiments to show the performance of the force sensor. The developed sensor element has a 200 μm in diameter single cilium with 1:5 aspect ratio and shows a detection range up to 1 mN with a sensitivity of 1.6 Ω/mN and a resolution of 31 μN. The simple fabrication process of the sensor allows easy optimization of the sensor performance to meet the needs of different applications.

  7. A single magnetic nanocomposite cilia force sensor

    KAUST Repository

    Alfadhel, Ahmed

    2016-04-20

    The advancements in fields like robotics and medicine continuously require improvements of sensor devices and more engagement of cooperative sensing technologies. For example, instruments such as tweezers with sensitive force sensory heads could provide the ability to sense a variety of physical quantities in real time, such as the amount and direction of the force applied or the texture of the gripped object. Force sensors with such abilities could be great solutions toward the development of smart surgical tools. In this work, a unique force sensor that can be integrated at the tips of robotic arms or surgical tools is reported. The force sensor consists of a single bioinspired, permanent magnetic and highly elastic nanocomposite cilia integrated on a magnetic field sensing element. The nanocomposite is prepared from permanent magnetic nanowires incorporated into the highly elastic polydimethylsiloxane. We demonstrate the potential of this concept by performing several experiments to show the performance of the force sensor. The developed sensor element has a 200 μm in diameter single cilium with 1:5 aspect ratio and shows a detection range up to 1 mN with a sensitivity of 1.6 Ω/mN and a resolution of 31 μN. The simple fabrication process of the sensor allows easy optimization of the sensor performance to meet the needs of different applications.

  8. A Simple Method for Assessing Upper-Limb Force-Velocity Profile in Bench Press.

    Science.gov (United States)

    Rahmani, Abderrahmane; Samozino, Pierre; Morin, Jean-Benoit; Morel, Baptiste

    2018-02-01

    To analyze the reliability and validity of a field computation method based on easy-to-measure data to assess the mean force ([Formula: see text]) and velocity ([Formula: see text]) produced during a ballistic bench-press movement and to verify that the force-velocity profile (F-v) obtained with multiple loaded trials is accurately described. Twelve participants performed ballistic bench presses against various lifted mass from 30% to 70% of their body mass. For each trial, [Formula: see text] and [Formula: see text] were determined from an accelerometer (sampling rate 500 Hz; reference method) and a simple computation method based on upper-limb mass, barbell flight height, and push-off distance. These [Formula: see text] and [Formula: see text] data were used to establish the F-v relationship for each individual and method. A strong to almost perfect reliability was observed between the 2 trials (ICC > .90 for [Formula: see text] and .80 for [Formula: see text], CV%  .80, P push-off distance).

  9. Grip strength is strongly associated with height, weight and gender in childhood : a cross sectional study of 2241 children and adolescents providing reference values

    NARCIS (Netherlands)

    Ploegmakers, Joris J. W.; Hepping, Ann M.; Geertzen, Jan H. B.; Bulstra, Sjoerd K.; Stevens, Martin

    2013-01-01

    Question: What are reference values for grip strength in children and adolescents based on a large and heterogeneous study population? What is the association of grip strength with age, gender, weight, and height in this population? Design: Cross-sectional study. Participants: Participants were

  10. Association between dietary protein intake and grip strength among adults aged 51 years and over: What We Eat in America, National Health and Nutrition Examination Survey 2011-2014.

    Directory of Open Access Journals (Sweden)

    Suruchi Mishra

    Full Text Available Distributing daily protein intake evenly across meals (∼25-30g/meal has been suggested to improve muscle mass. The aim of this research is to examine the association between grip strength, total protein intake and its distribution across day's meals in older adults.Nationally representative dietary intake data of adults aged 51 years and older (n = 4,123 who participated in What We Eat in America, NHANES 2011-2014 were analyzed. Protein intake per day and per eating occasion (breakfast, lunch, dinner, and snack were determined. Combined grip strength was calculated and expressed in kilograms. Grip strength of individuals consuming ≥25g protein at 1 eating occasion was compared with those consuming same level of protein at 2 and 3 or more eating occasions. Grip strength of individuals in quartile 1 of daily protein intake was compared to those in the other quartiles. All associations were examined without and with adjustment for age, race/ethnicity, physical activity, health status, and smoking status. The comparison involving eating occasions and protein intake quartiles were further adjusted for daily protein intake and energy intake, respectively.Only 33% of men and 19% of women had protein intake of ≥25g at 2 or more eating occasions. These individuals also had higher grip strength and daily protein intake. Grip strength was positively associated with consumption of ≥25g protein at 2 eating occasions as compared to consumption of same level of protein at 1 eating occasion (p<0.05 in unadjusted model, but not when adjusted. Grip strength was positively associated with daily protein intake among women in quartiles 3 and 4 (p<0.05 of protein intake in both unadjusted and adjusted models compared to lowest protein intake. Among men, grip strength was associated with daily protein intake in quartiles 3 and 4 (p<0.05 in the unadjusted model, but not when adjusted.In a nationally representative sample of older adults, consuming ≥25g

  11. A new classification for 'Pistol Grip Deformity'. Correlation between the severity of the deformity and the grade of osteoarthritis of the hip

    International Nuclear Information System (INIS)

    Ipach, Ingmar; Mittag, F.; Sachsenmaier, S.; Kluba, T.; Heinrich, P.

    2011-01-01

    Purpose: Two types of femoroacetabular impingement (FAI) are described as reasons for the early development of osteoarthritis of the hip. Cam impingement develops from contact between an abnormal head-neck junction and the acetabular rim. Pincer impingement is characterized by local or general overcoverage of the femoral head by the acetabular rim. Both forms might cause early osteoarthritis of the hip. A decreased head/neck offset has been recognized on AP pelvic views and labeled as 'pistol grip deformity'. The aim of the study was to develop a classification for this deformity with regard to the stage of osteoarthritis of the hip. Materials and Methods: 76 pelvic and axial views were analyzed for alpha angle and head ratio. 22 of them had a normal shape in the head-neck region and no osteoarthritis signs, 27 had a 'pistol grip deformity' and osteoarthritis I and 27 had a 'pistol grip deformity' and osteoarthritis II -IV . The CART method was used to develop a classification. Results: There was a statistically significant correlation between alpha angle and head ratio. A statistically significant difference in alpha angle and head ratio was seen between the three groups. Using the CART method, we developed a three-step classification system for the 'pistol grip deformity' with very high accuracy. This deformity was aggravated by increasing age. Conclusion: Using this model it is possible to differentiate between normal shapes of the head-neck junction and different severities of the pistol grip deformity. (orig.)

  12. Association between dietary protein intake and grip strength among adults aged 51 years and over: What We Eat in America, National Health and Nutrition Examination Survey 2011-2014.

    Science.gov (United States)

    Mishra, Suruchi; Goldman, Joseph D; Sahyoun, Nadine R; Moshfegh, Alanna J

    2018-01-01

    Distributing daily protein intake evenly across meals (∼25-30g/meal) has been suggested to improve muscle mass. The aim of this research is to examine the association between grip strength, total protein intake and its distribution across day's meals in older adults. Nationally representative dietary intake data of adults aged 51 years and older (n = 4,123) who participated in What We Eat in America, NHANES 2011-2014 were analyzed. Protein intake per day and per eating occasion (breakfast, lunch, dinner, and snack) were determined. Combined grip strength was calculated and expressed in kilograms. Grip strength of individuals consuming ≥25g protein at 1 eating occasion was compared with those consuming same level of protein at 2 and 3 or more eating occasions. Grip strength of individuals in quartile 1 of daily protein intake was compared to those in the other quartiles. All associations were examined without and with adjustment for age, race/ethnicity, physical activity, health status, and smoking status. The comparison involving eating occasions and protein intake quartiles were further adjusted for daily protein intake and energy intake, respectively. Only 33% of men and 19% of women had protein intake of ≥25g at 2 or more eating occasions. These individuals also had higher grip strength and daily protein intake. Grip strength was positively associated with consumption of ≥25g protein at 2 eating occasions as compared to consumption of same level of protein at 1 eating occasion (peating occasions was not associated with grip strength. However, higher daily protein intake was positively associated with grip strength in women.

  13. Grip strength in a cohort of older medical inpatients in Malaysia: a pilot study to describe the range, determinants and association with length of hospital stay.

    Science.gov (United States)

    Keevil, Victoria; Mazzuin Razali, Rizah; Chin, Ai-Vyrn; Jameson, Karen; Aihie Sayer, Avan; Roberts, Helen

    2013-01-01

    Grip strength is a marker of sarcopenia, the age-related decline in muscle mass and function, and has been little researched in Asian populations. We aimed to describe the feasibility and acceptability of measuring grip strength in hospitalized, older people in Malaysia and to explore its range, determinants and association with length of stay. Patients admitted acutely to the geriatrics ward of a teaching hospital were consecutively recruited. Inability to consent or use the dynamometer led to exclusion. Maximum grip strength, anthropometric data, length of hospital stay, discharge destination, 3-point Barthel score, mini-mental state examination, falls history and number of co-morbidities and medications on admission were recorded. 80/153 (52%) eligible patients were recruited (52 women; age range 64-100 years). 9/153 (6%) refused to participate and 64/153 (42%) were excluded (34 too unwell, 24 unable to consent, 4 unable to use the dynamometer, 2 other reasons). 76/80 patients (95%) reported that they would undergo grip strength measurement again. Determinants were similar to those of Caucasian populations but grip strength values were lower. After adjustment for sex, age and height, stronger grip strength was associated with shorter length of stay [hazard ratio 1.05 (95% CI 1.00, 1.09; P=0.03)]. This is the first report of grip strength measurement in hospitalized older people in Malaysia. It was feasible, acceptable to participants and associated with length of stay. Further research is warranted to elucidate the normative range in different ethnic groups and explore its potential use in clinical practice in Malaysia. Copyright © 2012 Elsevier Ireland Ltd. All rights reserved.

  14. Dynamic force profile in hydraulic hybrid vehicles: a numerical investigation

    Science.gov (United States)

    Mohaghegh-Motlagh, Amin; Elahinia, Mohammad H.

    2010-04-01

    A hybrid hydraulic vehicle (HHV) combines a hydraulic sub-system with the conventional drivetrain in order to improve fuel economy for heavy vehicles. The added hydraulic module manages the storage and release of fluid power necessary to assist the motion of the vehicle. The power collected by a pump/motor (P/M) from the regenerative braking phase is stored in a high-pressure accumulator and then released by the P/M to the driveshaft during the acceleration phase. This technology is effective in significantly improving fuel-economy for heavy-class vehicles with frequent stop-and-go drive schedules. Despite improved fuel economy and higher vehicle acceleration, noise and vibrations are one of the main problems of these vehicles. The dual function P/Ms are the main source of noise and vibration in a HHV. This study investigates the dynamics of a P/M and particularly the profile and frequency-dependence of the dynamic forces generated by a bent-axis P/M unit. To this end, the fluid dynamics side of the problem has been simplified for investigating the system from a dynamics perspective. A mathematical model of a bent axis P/M has been developed to investigate the cause of vibration and noise in HHVs. The forces are calculated in time and frequency domains. The results of this work can be used to study the vibration response of the chassis and to design effective vibration isolation systems for HHVs.

  15. Estimation of Handgrip Force from SEMG Based on Wavelet Scale Selection.

    Science.gov (United States)

    Wang, Kai; Zhang, Xianmin; Ota, Jun; Huang, Yanjiang

    2018-02-24

    This paper proposes a nonlinear correlation-based wavelet scale selection technology to select the effective wavelet scales for the estimation of handgrip force from surface electromyograms (SEMG). The SEMG signal corresponding to gripping force was collected from extensor and flexor forearm muscles during the force-varying analysis task. We performed a computational sensitivity analysis on the initial nonlinear SEMG-handgrip force model. To explore the nonlinear correlation between ten wavelet scales and handgrip force, a large-scale iteration based on the Monte Carlo simulation was conducted. To choose a suitable combination of scales, we proposed a rule to combine wavelet scales based on the sensitivity of each scale and selected the appropriate combination of wavelet scales based on sequence combination analysis (SCA). The results of SCA indicated that the scale combination VI is suitable for estimating force from the extensors and the combination V is suitable for the flexors. The proposed method was compared to two former methods through prolonged static and force-varying contraction tasks. The experiment results showed that the root mean square errors derived by the proposed method for both static and force-varying contraction tasks were less than 20%. The accuracy and robustness of the handgrip force derived by the proposed method is better than that obtained by the former methods.

  16. Light-Absorbing Aerosol during NASA GRIP: Overview of Observations in the Free Troposphere and Associated with Tropical Storm Systems

    Science.gov (United States)

    Ziemba, L. D.; Beyersdorf, A. J.; Chen, G.; Corr, C. A.; Craig, L.; Dhaniyala, S.; Dibb, J. E.; Hudgins, C. H.; Ismail, S.; Latham, T.; Nenes, A.; Thornhill, K. L.; Winstead, E.; Anderson, B. E.

    2010-12-01

    Aerosols play a significant role in regulating Earth’s climate. Absorbing aerosols typically constitute a small fraction of ambient particle mass but can contribute significantly to direct and indirect climate forcing depending on size, mixing state, concentration, chemical composition, and vertical and spatial distribution. Aerosols may also significantly affect tropical storm/hurricane dynamics through direct light absorption and activation as cloud nuclei. An extensive suite of instrumentation measuring aerosol chemical, physical, and optical properties was deployed aboard the NASA DC-8 to characterize aerosol during the NASA GRIP (Genesis and Rapid Intensification Processes; August-September 2010) mission. The majority of flight time was spent at high altitude (greater than 9 km) and thus much of the sampling was done in the free troposphere, including extensive sampling in the vicinity of tropical storm systems and more diffuse cirrus clouds. With operations based in Fort Lauderdale, FL and St. Croix, U.S. Virgin Islands, a large geographic region was sampled including much of the Gulf of Mexico and tropical Atlantic Ocean. Observations are reported for light-absorbing carbon aerosol (mainly black carbon, BC) primarily using a single particle soot photometer (SP2). The SP2 employs single-particle laser-induced incandescence to provide a mass-specific measurement not subject to scattering interference that is optimal for the low concentration environments like those encountered during GRIP. BC mass concentrations, 100-500 nm size distributions, and mixing state (i.e. coating thickness of scattering material) are presented. Total and sub-micron aerosol absorption coefficients (principally from BC and dust aerosol) are reported using a particle soot absorption photometer (PSAP) along with comparisons with calculated absorption coefficients derived from SP2 observations in various conditions. In addition, dust aerosol is specifically identified using optical and

  17. An experimental validation of the influence of flow profiles and stratified two-phase flow to Lorentz force velocimetry for weakly conducting fluids

    Science.gov (United States)

    Wiederhold, Andreas; Ebert, Reschad; Resagk, Christian; Research Training Group: "Lorentz Force Velocimetry; Lorentz Force Eddy Current Testing" Team

    2016-11-01

    We report about the feasibility of Lorentz force velocimetry (LFV) for various flow profiles. LFV is a contactless non-invasive technique to measure flow velocity and has been developed in the last years in our institute. This method is advantageous if the fluid is hot, aggressive or opaque like glass melts or liquid metal flows. The conducted experiments shall prove an increased versatility for industrial applications of this method. For the force measurement we use an electromagnetic force compensation balance. As electrolyte salty water is used with an electrical conductivity in the range of 0.035 which corresponds to tap water up to 20 Sm-1. Because the conductivity is six orders less than that of liquid metals, here the challenging bottleneck is the resolution of the measurement system. The results show only a slight influence in the force signal at symmetric and strongly asymmetric flow profiles. Furthermore we report about the application of LFV to stratified two-phase flows. We show that it is possible to detect interface instabilities, which is important for the dimensioning of liquid metal batteries. Deutsche Forschungsgemeinschaft DFG.

  18. Study of the effects of the hand grip and finger strengths on the friction and petrissage - the massage manipulations - of the students who take massage courses: Kütahya City example

    Directory of Open Access Journals (Sweden)

    Erzeybek Mustafa Said

    2016-01-01

    Full Text Available In this research, the effect of the hand grip and finger strengths on the power development between the friction and petrissage techniques - the massage manipulations - have been studied. To the study that has been structured as a single group pretest/post test, 36 healthy males who are the students of the University of Dumlupınar, Academy of Physical Education and Sports and who take massage courses (age = 19.72 ± 1.56 years (average ± Sd have been included. The practical massage course has continued for 12 weeks, two days a week for a total of one hour and the hand grip strength of both hands (right hand grip strength = RHG, left hand grip strength = LHG and the grip strength of both fingers (right finger strength = RF, left finger strength = LF have been recorded at the beginning. For the measurements carried out before and later of the study with regard to the hand grip strength, a Takkei branded hand dynamometer and with regard to the finger grip strength a (baseline branded pinch meter have been used. All measurements have been repeated twice and for the analysis, the average values obtained from two deads have been used. For statistical analysis, with regard to the changes in the pre test-post test finger strength and hand grip strength, paired-samples t test has been used. The significance limit has been defined as p0.05. It is possible to report that massaging regularly with both hands is efficient for the development of the finger and hand grip strengths; especially, with regard to the friction (circular movements that are generally carried out with fingers and petrissage (kneading that is generally carried out with the palm techniques.

  19. Age and Sex Differences in Controlled Force Exertion Measured by a Computing Bar Chart Target-Pursuit System

    Science.gov (United States)

    Nagasawa, Yoshinori; Demura, Shinichi

    2009-01-01

    This study aimed to examine the age and sex differences in controlled force exertion measured by the bar chart display in 207 males (age 42.1 [plus or minus] 19.8 years) and 249 females (age 41.7 [plus or minus] 19.1 years) aged 15 to 86 years. The subjects matched their submaximal grip strength to changing demand values, which appeared as a…

  20. Test-Retest Reliability of Measurements of Hand-Grip Strength Obtained by Dynamometry from Older Adults: A Systematic Review of Research in the PubMed Database.

    Science.gov (United States)

    Bohannon, R W

    2017-01-01

    A systematic review was performed to summarize literature describing the test-retest reliability of grip strength measures obtained from older adults. Relevant literature was identified via a PubMed search. Seventeen articles were deemed appropriate based on inclusion and exclusion criteria. The relative test-retest reliability of grip strength measures obtained by dynamometry was good to excellent (intra-class correlation coefficients > 0.80) in all but 3 studies, which involved older adults with severe dementia. Absolute reliability, as indicated by summary statistics such as the minimum detectable change (95%), was more variable. As a percentage, that change ranged from 14.5% to 98.5%. Consequently, clinicians can be confident in the relative reliability of grip strength measures obtained from at risk older adults. However, relatively large percentage changes in grip strength may be necessary to conclude with confidence that a real change has occurred over time in some populations.

  1. Draft forces prediction model for standard single tines by using principles of soil mechanics and soil profile evaluation

    Directory of Open Access Journals (Sweden)

    Amer Khalid Ahmed Al-Neama

    2017-06-01

    Full Text Available This paper explains a model to predict the draft force acting on varying standard single tines by using principles of soil mechanics and soil profile evaluation. Draft force (Fd measurements were made with four standard single tines comprising Heavy Duty, Double Heart, Double Heart with Wings and Duck Foot. Tine widths were 6.5, 13.5, 45 and 40 cm, respectively. The test was conducted in a soil bin with sandy loam soil. The effects of forward speeds and working depths on draft forces were investigated under controlled lab conditions. Results were evaluated based on a prediction model. A good correlation between measured and predicted Fd values for all tines with an average absolute variation less than 15 % was found.

  2. A Strain-Based Method to Detect Tires’ Loss of Grip and Estimate Lateral Friction Coefficient from Experimental Data by Fuzzy Logic for Intelligent Tire Development

    Directory of Open Access Journals (Sweden)

    Jorge Yunta

    2018-02-01

    Full Text Available Tires are a key sub-system of vehicles that have a big responsibility for comfort, fuel consumption and traffic safety. However, current tires are just passive rubber elements which do not contribute actively to improve the driving experience or vehicle safety. The lack of information from the tire during driving gives cause for developing an intelligent tire. Therefore, the aim of the intelligent tire is to monitor tire working conditions in real-time, providing useful information to other systems and becoming an active system. In this paper, tire tread deformation is measured to provide a strong experimental base with different experiments and test results by means of a tire fitted with sensors. Tests under different working conditions such as vertical load or slip angle have been carried out with an indoor tire test rig. The experimental data analysis shows the strong relation that exists between lateral force and the maximum tensile and compressive strain peaks when the tire is not working at the limit of grip. In the last section, an estimation system from experimental data has been developed and implemented in Simulink to show the potential of strain sensors for developing intelligent tire systems, obtaining as major results a signal to detect tire’s loss of grip and estimations of the lateral friction coefficient.

  3. Associations Between Diabetes and Both Cardiovascular Disease and All-Cause Mortality Are Modified by Grip Strength: Evidence From UK Biobank, a Prospective Population-Based Cohort Study.

    Science.gov (United States)

    Celis-Morales, Carlos A; Petermann, Fanny; Hui, Li; Lyall, Donald M; Iliodromiti, Stamatina; McLaren, James; Anderson, Jana; Welsh, Paul; Mackay, Daniel F; Pell, Jill P; Sattar, Naveed; Gill, Jason M R; Gray, Stuart R

    2017-12-01

    Grip strength and diabetes are predictors of mortality and cardiovascular disease (CVD), but whether these risk factors interact to predispose to adverse health outcomes is unknown. This study determined the interactions between diabetes and grip strength and their association with health outcomes. We undertook a prospective, general population cohort study by using UK Biobank. Cox proportional hazards models were used to explore the associations between both grip strength and diabetes and the outcomes of all-cause mortality and CVD incidence/mortality as well as to test for interactions between diabetes and grip strength. A total of 347,130 UK Biobank participants with full data available (mean age 55.9 years, BMI 27.2 kg/m 2 , 54.2% women) were included in the analysis, of which 13,373 (4.0%) had diabetes. Over a median follow-up of 4.9 years (range 3.3-7.8 years), 6,209 died (594 as a result of CVD), and 4,301 developed CVD. Participants with diabetes were at higher risk of all-cause and CVD mortality and CVD incidence. Significant interactions ( P strength. Similar results were observed for all-cause mortality and CVD incidence. Risk of adverse health outcomes among people with diabetes is lower in those with high grip strength. Low grip strength may be useful to identify a higher-risk subgroup of patients with diabetes. Intervention studies are required to determine whether resistance exercise can reduce risk. © 2017 by the American Diabetes Association.

  4. Constraints on grip selection in hemiparetic cerebral palsy: effects of lesional side, end-point accuracy, and context.

    Science.gov (United States)

    Steenbergen, Bert; Meulenbroek, Ruud G J; Rosenbaum, David A

    2004-04-01

    This study was concerned with selection criteria used for grip planning in adolescents with left or right hemiparetic cerebral palsy. In the first experiment, we asked participants to pick up a pencil and place the tip in a pre-defined target region. We varied the size of the target to test the hypothesis that increased end-point precision demands would favour the use of a grip that affords end-state comfort. In the second experiment, we studied grip planning in three task contexts that were chosen to let us test the hypothesis that a more functional task context would likewise promote the end-state comfort effect. When movements were performed with the impaired hand, we found that participants with right hemiparesis (i.e., left brain damage) aimed for postural comfort at the start rather than at the end of the object-manipulation phase in both experiments. By contrast, participants with left hemiparesis (i.e., right brain damage) did not favour a particular selection criterion with the impaired hand in the first experiment, but aimed for postural comfort at the start in the second experiment. When movements were performed with the unimpaired hand, grip selection criteria again differed for right and left hemiparetic participants. Participants with right hemiparesis did not favour a particular selection criterion with the unimpaired hand in the first experiment and only showed the end-state comfort effect in the most functional tasks of the second experiment. By contrast, participants with left hemiparesis showed the end-state comfort effect in all conditions of both experiments. These data suggest that the left hemisphere plays a special role in action planning, as has been recognized before, and that one of the deficits accompanying left brain damage is a deficit in forward movement planning, which has not been recognized before. Our findings have both theoretical and clinical implications.

  5. Feeling is Believing: a location limited channel based on grip pattern biometrics and cryptanalysis

    NARCIS (Netherlands)

    Buhan, I.R.; Doumen, J.M.; Hartel, Pieter H.; Veldhuis, Raymond N.J.

    We use grip pattern based biometrics as a location limited channel to achieve pre-authentication in a protocol that sets up a secure cannel between two handheld devices. The protocol efficiently calculates a shared secret key from biometric data using quantization and cryptanalysis. The protocol is

  6. Comparative study of maximum isometric grip strength in different sports

    Directory of Open Access Journals (Sweden)

    Noé Gomes Borges Junior

    2009-06-01

    Full Text Available The objective of this study was to compare maximum isometric grip strength (Fmaxbetween different sports and between the dominant (FmaxD and non-dominant (FmaxND hand. Twenty-nine male aikido (AI, jiujitsu (JJ, judo (JU and rowing (RO athletes and 21non-athletes (NA participated in the study. The hand strength test consisted of maintainingmaximum isometric grip strength for 10 seconds using a hand dynamometer. The position of the subjects was that suggested by the American Society of Hand Therapy. Factorial 2X5 ANOVA with Bonferroni correction, followed by a paired t test and Tukey test, was used for statistical analysis. The highest Fmax values were observed for the JJ group when using the dominant hand,followed by the JU, RO, AI and NA groups. Variation in Fmax could be attributed to handdominance (30.9%, sports modality (39.9% and the interaction between hand dominance andsport (21.3%. The present results demonstrated significant differences in Fmax between the JJ and AI groups and between the JJ and NA groups for both the dominant and non-dominant hand. Significant differences in Fmax between the dominant and non-dominant hand were only observed in the AI and NA groups. The results indicate that Fmax can be used for comparisonbetween different sports modalities, and to identify differences between the dominant and nondominanthand. Studies involving a larger number of subjects will permit the identification of differences between other modalities.

  7. Television Viewing, Walking Speed, and Grip Strength in a Prospective Cohort Study

    Science.gov (United States)

    KEEVIL, VICTORIA L.; WIJNDAELE, KATRIEN; LUBEN, ROBERT; SAYER, AVAN A.; WAREHAM, NICHOLAS J.; KHAW, KAY-TEE

    2015-01-01

    ABSTRACT Purpose Television (TV) watching is the most prevalent sedentary leisure time activity in the United Kingdom. We examined associations between TV viewing time, measured over 10 yr, and two objective measures of physical capability, usual walking speed (UWS) and grip strength. Methods Community-based participants (n = 8623; 48–92 yr old) enrolled in the European Prospective Investigation of Cancer—Norfolk study attended a third health examination (3HC, 2006–2011) for measurement of maximum grip strength (Smedley dynamometer) and UWS. TV viewing time was estimated using a validated questionnaire (n = 6086) administered during two periods (3HC, 2006–2007; 2HC, 1998–2000). Associations between physical capability and TV viewing time category (<2, 2 < 3, 3 < 4, and ≥4 h·d−1) at the 3HC, 2HC, and using an average of the two measures were explored. Sex-stratified analyses were adjusted for age, physical activity, anthropometry, wealth, comorbidity, smoking, and alcohol intake and combined if no sex–TV viewing time interactions were identified. Results Men and women who watched the least TV at the 2HC or 3HC walked at a faster usual pace than those who watched the most TV. There was no evidence of effect modification by sex (Pinteraction = 0.09), and in combined analyses, participants who watched for <2 h·d−1 on average walked 4.29 cm·s−1 (95% confidence interval, 2.56–6.03) faster than those who watched for ≥4 h·d−1, with evidence of a dose–response association (Ptrend < 0.001). However, no strong associations with grip strength were found. Conclusions TV viewing time predicted UWS in older adults. More research is needed to inform public health policy and prospective associations between other measures of sedentariness, such as total sitting time or objectively measured sedentary time, and physical capability should be explored. PMID:25785826

  8. Force Profiles of a Linear Switched Reluctance Motor Having Special Pole Face Shapes

    Directory of Open Access Journals (Sweden)

    CHADRESEKAR, V.

    2010-11-01

    Full Text Available In this paper, the results of a finite element analysis are carried out on an new stator geometry of a three phase longitudinal flux Linear Switched Reluctance Motor (LSRM. In the new geometry, pole shoes are affixed to the stator poles. Static and dynamic characteristics for the proposed structure have been highlighted. Motor performance for variable load conditions is discussed. Frequency spectrum analyses of force profile using the fast Fourier transform (FFT are described to predict the vibration frequencies. The 2-Dimensional (2-D finite element analysis (FEA and the experimental results of this paper prove that LSRMs are one of the strong candidates for linear propulsion drives.

  9. Comparison of hand grip strength and upper limb pressure pain threshold between older adults with or without non-specific shoulder pain

    Directory of Open Access Journals (Sweden)

    Cesar Calvo Lobo

    2017-02-01

    Full Text Available Background There is a high prevalence of non-specific shoulder pain associated with upper limb functional limitations in older adults. The purpose of this study was to determine the minimal clinically important differences (MCID of grip strength and pressure pain threshold (PPT in the upper limb between older adults with or without non-specific shoulder pain. Methods A case-control study was carried out following the Strengthening the Reporting of Observational Studies in Epidemiology (STROBE criteria. A sample of 132 shoulders (mean ± SD years with (n = 66; 76.04 ± 7.58 and without (n = 66; 75.05 ± 6.26 non-specific pain were recruited. The grip strength and PPT of the anterior deltoid and extensor carpi radialis brevis (ECRB muscles were assessed. Results There were statistically significant differences (mean ± SD; P-value for anterior deltoid PPT (2.51 ± 0.69 vs 3.68 ± 0.65, kg/cm2; P < .001, ECRB PPT (2.20 ± 0.60 vs 3.35 ± 0.38 kg/cm2; P < .001 and grip strength (20.78 ± 10.94 vs 24.63 ± 9.38 kg; P = .032 between shoulders with and without non-specific pain, respectively. Discussion The MCID of 1.17 kg/cm2, 1.15 kg/cm2 and 3.84 kg were proposed for anterior deltoid PPT, ECRB PPT and grip strength, respectively, to assess the upper limb of older adults with non-specific shoulder pain after treatment. In addition, univariate and multivariate (linear regression and regression trees analyses may be used to consider age distribution, sex, pain intensity, grip strength and PPT in older adults including clinical and epidemiological studies with non-specific shoulder pain.

  10. Corrosion caused by elevator and spider marks on CRA pipe: Comparison of conventional inserts and a new gripping system

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1997-05-01

    Corrosion-resistant alloys (CRA) are used to reduce corrosion damage to casing and tubing strings and prolong the life span of the well pipe. An analysis of various corrosion mechanisms shows that surface integrity is an important factor in corrosion prevention. Surface damage caused by inappropriate handling or conventional slip markings contribute directly to the development and propagation of corrosion. A newly developed gripping system distributes the load equally onto a large number of small peaks, minimizing the indentation of each single peak. The new gripping system does not damage the surface integrity of the pipe, virtually eliminating the corrosion potential.

  11. Associations of muscle force, power, cross-sectional muscle area and bone geometry in older UK men.

    Science.gov (United States)

    Zengin, Ayse; Pye, Stephen R; Cook, Michael J; Adams, Judith E; Rawer, Rainer; Wu, Frederick C W; O'Neill, Terence W; Ward, Kate A

    2017-08-01

    Ageing is associated with sarcopenia, osteoporosis, and increased fall risk, all of which contribute to increased fracture risk. Mechanically, bone strength adapts in response to forces created by muscle contractions. Adaptations can be through changes in bone size, geometry, and bending strength. Muscle mass is often used as a surrogate for muscle force; however, force can be increased without changes in muscle mass. Increased fall risk with ageing has been associated with a decline in muscle power-which is a measure of mobility. The aims of this study were as follows: (i) to investigate the relationship between muscle parameters in the upper and lower limbs with age in UK men and the influence of ethnicity on these relationships; (ii) to examine the relationships between jump force/grip strength/cross-sectional muscle area (CSMA) with bone outcomes at the radius and tibia. White European, Black Afro-Caribbean, and South Asian men aged 40-79 years were recruited from Manchester, UK. Cortical bone mineral content, cross-sectional area, cortical area, cross-sectional moment of inertia, and CSMA were measured at the diaphysis of the radius and tibia using peripheral quantitative computed tomography. Lower limb jump force and power were measured from a single two-legged jump performed on a ground-reaction force platform. Grip strength was measured using a dynamometer. Associations between muscle and bone outcomes was determined using linear regression with adjustments for age, height, weight, and ethnicity. Three hundred and one men were recruited. Jump force was negatively associated with age; for every 10 year increase in age, there was a 4% reduction in jump force (P force was positively associated with tibial bone outcomes: a 1 standard deviation greater jump force was associated with significantly higher cortical bone mineral content 3.1%, cross-sectional area 4.2%, cortical area 3.4%, and cross-sectional moment of inertia 6.8% (all P force and power are

  12. Radial force distribution changes associated with tangential force production in cylindrical grasping, and the importance of anatomical registration.

    Science.gov (United States)

    Pataky, Todd C; Slota, Gregory P; Latash, Mark L; Zatsiorsky, Vladimir M

    2012-01-10

    Radial force (F(r)) distributions describe grip force coordination about a cylindrical object. Recent studies have employed only explicit F(r) tasks, and have not normalized for anatomical variance when considering F(r) distributions. The goals of the present study were (i) to explore F(r) during tangential force production tasks, and (ii) to examine the extent to which anatomical registration (i.e. spatial normalization of anatomically analogous structures) could improve signal detectability in F(r) data. Twelve subjects grasped a vertically oriented cylindrical handle (diameter=6 cm) and matched target upward tangential forces of 10, 20, and 30 N. F(r) data were measured using a flexible pressure mat with an angular resolution of 4.8°, and were registered using piecewise-linear interpolation between five manually identified points-of-interest. Results indicate that F(r) was primarily limited to three contact regions: the distal thumb, the distal fingers, and the fingers' metatacarpal heads, and that, while increases in tangential force caused significant increases in F(r) for these regions, they did not significantly affect the F(r) distribution across the hand. Registration was found to substantially reduce between-subject variability, as indicated by both accentuated F(r) trends, and amplification of the test statistic. These results imply that, while subjects focus F(r) primarily on three anatomical regions during cylindrical grasp, inter-subject anatomical differences introduce a variability that, if not corrected for via registration, may compromise one's ability to draw anatomically relevant conclusions from grasping force data. Copyright © 2011 Elsevier Ltd. All rights reserved.

  13. Comparative study of maximum isometric grip strength in different sports

    Directory of Open Access Journals (Sweden)

    Noé Gomes Borges Junior

    2009-01-01

    Full Text Available http://dx.doi.org/10.5007/1980-0037.2009v11n3p292   The objective of this study was to compare maximum isometric grip strength (Fmaxbetween different sports and between the dominant (FmaxD and non-dominant (FmaxND hand. Twenty-nine male aikido (AI, jiujitsu (JJ, judo (JU and rowing (RO athletes and 21non-athletes (NA participated in the study. The hand strength test consisted of maintainingmaximum isometric grip strength for 10 seconds using a hand dynamometer. The position of the subjects was that suggested by the American Society of Hand Therapy. Factorial 2X5 ANOVA with Bonferroni correction, followed by a paired t test and Tukey test, was used for statistical analysis. The highest Fmax values were observed for the JJ group when using the dominant hand,followed by the JU, RO, AI and NA groups. Variation in Fmax could be attributed to handdominance (30.9%, sports modality (39.9% and the interaction between hand dominance andsport (21.3%. The present results demonstrated significant differences in Fmax between the JJ and AI groups and between the JJ and NA groups for both the dominant and non-dominant hand. Significant differences in Fmax between the dominant and non-dominant hand were only observed in the AI and NA groups. The results indicate that Fmax can be used for comparisonbetween different sports modalities, and to identify differences between the dominant and nondominanthand. Studies involving a larger number of subjects will permit the identification of differences between other modalities.

  14. Evolution of etched nuclear track profiles of alpha particles in CR-39 by atomic force microscopy

    International Nuclear Information System (INIS)

    Félix-Bautista, R.; Hernández-Hernández, C.; Zendejas-Leal, B.E.; Fragoso, R.; Golzarri, J.I.; Vázquez-López, C.; Espinosa, G.

    2013-01-01

    A series of atomic force microscopy (AFM) images of etched nuclear tracks has been obtained and used to calculate the nuclear track registration sensitivity parameter V(x) = Vt(x)/Vb. Due to the AFM limitations the samples were irradiated normally to the surface, and with energies attenuated in order to include the Bragg peak region in the AFM piezo-scanner z movement range. The simulation of the track profile evolution was then obtained. The different stages of etched nuclear track profiles were rendered. - Highlights: ► Using AFM we reach that Bragg peak region of etched tracks in CR-39. ► The etched track sensitivity V was calculated by data obtained by AFM. ► The evolucion of etched nuclear tracks was simulated by data achieved by AFM

  15. Adaptation of reach-to-grasp movement in response to force perturbations.

    Science.gov (United States)

    Rand, M K; Shimansky, Y; Stelmach, G E; Bloedel, J R

    2004-01-01

    This study examined how reach-to-grasp movements are modified during adaptation to external force perturbations applied on the arm during reach. Specifically, we examined whether the organization of these movements was dependent upon the condition under which the perturbation was applied. In response to an auditory signal, all subjects were asked to reach for a vertical dowel, grasp it between the index finger and thumb, and lift it a short distance off the table. The subjects were instructed to do the task as fast as possible. The perturbation was an elastic load acting on the wrist at an angle of 105 deg lateral to the reaching direction. The condition was modified by changing the predictability with which the perturbation was applied in a given trial. After recording unperturbed control trials, perturbations were applied first on successive trials (predictable perturbations) and then were applied randomly (unpredictable perturbations). In the early predictable perturbation trials, reach path length became longer and reaching duration increased. As more predictable perturbations were applied, the reach path length gradually decreased and became similar to that of control trials. Reaching duration also decreased gradually as the subjects adapted by exerting force against the perturbation. In addition, the amplitude of peak grip aperture during arm transport initially increased in response to repeated perturbations. During the course of learning, it reached its maximum and thereafter slightly decreased. However, it did not return to the normal level. The subjects also adapted to the unpredictable perturbations through changes in both arm transport and grasping components, indicating that they can compensate even when the occurrence of the perturbation cannot be predicted during the inter-trial interval. Throughout random perturbation trials, large grip aperture values were observed, suggesting that a conservative aperture level is set regardless of whether the

  16. Gloss, colour and grip: multifunctional epidermal cell shapes in bee- and bird-pollinated flowers.

    Science.gov (United States)

    Papiorek, Sarah; Junker, Robert R; Lunau, Klaus

    2014-01-01

    Flowers bear the function of filters supporting the attraction of pollinators as well as the deterrence of floral antagonists. The effect of epidermal cell shape on the visual display and tactile properties of flowers has been evaluated only recently. In this study we quantitatively measured epidermal cell shape, gloss and spectral reflectance of flowers pollinated by either bees or birds testing three hypotheses: The first two hypotheses imply that bee-pollinated flowers might benefit from rough surfaces on visually-active parts produced by conical epidermal cells, as they may enhance the colour signal of flowers as well as the grip on flowers for bees. In contrast, bird-pollinated flowers might benefit from flat surfaces produced by flat epidermal cells, by avoiding frequent visitation from non-pollinating bees due to a reduced colour signal, as birds do not rely on specific colour parameters while foraging. Moreover, flat petal surfaces in bird-pollinated flowers may hamper grip for bees that do not touch anthers and stigmas while consuming nectar and thus, are considered as nectar thieves. Beside this, the third hypothesis implies that those flower parts which are vulnerable to nectar robbing of bee- as well as bird-pollinated flowers benefit from flat epidermal cells, hampering grip for nectar robbing bees. Our comparative data show in fact that conical epidermal cells are restricted to visually-active parts of bee-pollinated flowers, whereas robbing-sensitive parts of bee-pollinated as well as the entire floral surface of bird-pollinated flowers possess on average flat epidermal cells. However, direct correlations between epidermal cell shape and colour parameters have not been found. Our results together with published experimental studies show that epidermal cell shape as a largely neglected flower trait might act as an important feature in pollinator attraction and avoidance of antagonists, and thus may contribute to the partitioning of flower-visitors.

  17. Gloss, colour and grip: multifunctional epidermal cell shapes in bee- and bird-pollinated flowers.

    Directory of Open Access Journals (Sweden)

    Sarah Papiorek

    Full Text Available Flowers bear the function of filters supporting the attraction of pollinators as well as the deterrence of floral antagonists. The effect of epidermal cell shape on the visual display and tactile properties of flowers has been evaluated only recently. In this study we quantitatively measured epidermal cell shape, gloss and spectral reflectance of flowers pollinated by either bees or birds testing three hypotheses: The first two hypotheses imply that bee-pollinated flowers might benefit from rough surfaces on visually-active parts produced by conical epidermal cells, as they may enhance the colour signal of flowers as well as the grip on flowers for bees. In contrast, bird-pollinated flowers might benefit from flat surfaces produced by flat epidermal cells, by avoiding frequent visitation from non-pollinating bees due to a reduced colour signal, as birds do not rely on specific colour parameters while foraging. Moreover, flat petal surfaces in bird-pollinated flowers may hamper grip for bees that do not touch anthers and stigmas while consuming nectar and thus, are considered as nectar thieves. Beside this, the third hypothesis implies that those flower parts which are vulnerable to nectar robbing of bee- as well as bird-pollinated flowers benefit from flat epidermal cells, hampering grip for nectar robbing bees. Our comparative data show in fact that conical epidermal cells are restricted to visually-active parts of bee-pollinated flowers, whereas robbing-sensitive parts of bee-pollinated as well as the entire floral surface of bird-pollinated flowers possess on average flat epidermal cells. However, direct correlations between epidermal cell shape and colour parameters have not been found. Our results together with published experimental studies show that epidermal cell shape as a largely neglected flower trait might act as an important feature in pollinator attraction and avoidance of antagonists, and thus may contribute to the partitioning of

  18. The predictive value of the extensor grip test for the effectiveness of bracing for tennis elbow

    NARCIS (Netherlands)

    Struijs, Peter A. A.; Assendelft, Willem J. J.; Kerkhoffs, Gino M. M. J.; Souer, Sebastiaan; van Dijk, C. Niek

    2005-01-01

    Background: Tennis elbow is a common complaint. Several treatment strategies, such as corticosteroid injections and physical therapy and braces, have been described. Hypothesis: The extensor grip test has predictive value in assessing the effectiveness of bracing in tennis elbow. Study Design:

  19. Grip-Pattern Verification for Smart Gun Based on Maximum-Pairwise Comparison and Mean-Template Comparison

    NARCIS (Netherlands)

    Shang, X.; Veldhuis, Raymond N.J.

    2008-01-01

    In our biometric verification system of a smart gun, the rightful user of a gun is authenticated by grip-pattern recognition. In this work verification will be done using two types of comparison methods, respectively. One is mean-template comparison, where the matching score between a test image and

  20. Hip muscle and hand-grip strength to differentiate between older fallers and non-fallers: a cross-sectional validity study

    Directory of Open Access Journals (Sweden)

    Gafner SC

    2017-12-01

    Full Text Available Simone C Gafner,1,2 Caroline H Bastiaenen,2,3 Serge Ferrari,4 Gabriel Gold,5 Philippe Terrier,6,7 Roger Hilfiker,8 Lara Allet1,91Department of Physiotherapy, HES-SO University of Applied Sciences and Arts of Western Switzerland, Geneva, Switzerland; 2Department of Epidemiology, Research Program Functioning and Rehabilitation, CAPHRI, Maastricht University, Maastricht, the Netherlands; 3Department of Health, School of Health Professions, Zurich University of Applied Sciences, Winterthur, 4Department of Internal Medicine Specialties, 5Department of Internal Medicine, Rehabilitation and Geriatrics, University Hospitals and University of Geneva, Geneva, 6Department of Research, Clinique romande de réadaptation SUVACare, 7Department of Research, Institute for Research in Rehabilitation, Sion, 8Department of Physiotherapy, School of Health Sciences, HES-SO Valais-Wallis, University of Applied Sciences and Arts of Western Switzerland, Valais, 9Department of Community Medicine, University Hospitals and University of Geneva, Geneva, Switzerland Background: Hip muscle weakness in older people seems to be an influencing factor of falls. Currently, it is unclear which muscles out of the hip muscle group play an important role in older people. A validating process in the measurement regarding muscle strength related to falls is necessary before answering that question.Objective: Firstly, we aimed to investigate which hip muscle group strength shows an acceptable level of distinction between older adult fallers and non-fallers compared to a predefined external criterion regarding falling. Secondly, we aimed to compare the same outcomes and questions for hand-grip strength in relation to the same external criterion.Design: This study was a cross-sectional validity study.Methods: The maximum voluntary isometric strength (MVIS and the rate of force generation of hip abductors (ABD, adductors, internal and external rotators, extensors, and flexors were measured

  1. Observing how others lift light or heavy objects: time-dependent encoding of grip force in the primary motor cortex.

    Science.gov (United States)

    Alaerts, Kaat; de Beukelaar, Toon T; Swinnen, Stephan P; Wenderoth, Nicole

    2012-07-01

    During movement observation, corticomotor excitability of the observer's primary motor cortex (M1) is modulated according to the force requirements of the observed action. Here, we explored the time course of observation-induced force encoding. Force-related changes in M1-excitability were assessed by delivering transcranial magnetic stimulations at distinct temporal phases of an observed reach-grasp-lift action. Temporal changes in force-related electromyographic activity were also assessed during active movement execution. In observation conditions in which a heavy object was lifted, M1-excitability was higher compared to conditions in which a light object was lifted. Both during observation and execution, differential force encoding tended to gradually increase from the grasping phase until the late lift phase. Surprisingly, however, during observation, force encoding was already present at the early reach phase: a time point at which no visual cues on the object's weight were available to the observer. As the observer was aware that the same weight condition was presented repeatedly, this finding may indicate that prior predictions concerning the upcoming weight condition are reflected by M1 excitability. Overall, findings may provide indications that the observer's motor system represents motor predictions as well as muscular requirements to infer the observed movement goal.

  2. Optimal Balance Between Force and Velocity Differs Among World-Class Athletes.

    Science.gov (United States)

    Giroux, Caroline; Rabita, Giuseppe; Chollet, Didier; Guilhem, Gaël

    2016-02-01

    Performance during human movements is highly related to force and velocity muscle capacities. Those capacities are highly developed in elite athletes practicing power-oriented sports. However, it is still unclear whether the balance between their force and velocity-generating capacities constitutes an optimal profile. In this study, we aimed to determine the effect of elite sport background on the force-velocity relationship in the squat jump, and evaluate the level of optimization of these profiles. Ninety-five elite athletes in cycling, fencing, taekwondo, and athletic sprinting, and 15 control participants performed squat jumps in 7 loading conditions (range: 0%-60% of the maximal load they were able to lift). Theoretical maximal power (Pm), force (F0), and velocity (v0) were determined from the individual force-velocity relationships. Optimal profiles were assessed by calculating the optimal force (F0th) and velocity (v0th). Athletic sprinters and cyclists produced greater force than the other groups (P balanced force-velocity profiles. Moreover, the differences between measured and optimal force-velocity profiles raise potential sources of performance improvement in elite athletes.

  3. Exoskeleton master controller with force-reflecting telepresence

    Science.gov (United States)

    Burke, James B.; Bartholet, Stephen J.; Nelson, David K.

    1992-01-01

    A thorough understanding of the requirements for successful master-slave robotic systems is becoming increasingly desirable. Such systems can aid in the accomplishment of tasks that are hazardous or inaccessible to humans. Although a history of use has proven master-slave systems to be viable, system requirements and the impact of specifications on the human factors side of system performance are not well known. In support of the next phase of teleoperation research being conducted at the Armstrong Research Laboratory, a force-reflecting, seven degree of freedom exoskeleton for master-slave teleoperation has been concepted, and is presently being developed. The exoskeleton has a unique kinematic structure that complements the structure of the human arm. It provides a natural means for teleoperating a dexterous, possibly redundant manipulator. It allows ease of use without operator fatigue and faithfully follows human arm and wrist motions. Reflected forces and moments are remotely transmitted to the operator hand grip using a cable transmission scheme. This paper presents the exoskeleton concept and development results to date. Conceptual design, hardware, algorithms, computer architecture, and software are covered.

  4. Association between grip strength and diabetes prevalence in black, South-Asian, and white European ethnic groups: a cross-sectional analysis of 418 656 participants in the UK Biobank study.

    Science.gov (United States)

    Ntuk, U E; Celis-Morales, C A; Mackay, D F; Sattar, N; Pell, J P; Gill, J M R

    2017-08-01

    To quantify the extent to which ethnic differences in muscular strength might account for the substantially higher prevalence of diabetes in black and South-Asian compared with white European adults. This cross-sectional study used baseline data from the UK Biobank study on 418 656 white European, black and South-Asian participants, aged 40-69 years, who had complete data on diabetes status and hand-grip strength. Associations between hand-grip strength and diabetes were assessed using logistic regression and were adjusted for potential confounding factors. Lower grip strength was associated with higher prevalence of diabetes, independent of confounding factors, across all ethnicities in both men and women. Diabetes prevalence was approximately three- to fourfold higher in South-Asian and two- to threefold higher in black participants compared with white European participants across all levels of grip strength, but grip strength in South-Asian men and women was ~ 5-6 kg lower than in the other ethnic groups. Thus, the attributable risk for diabetes associated with low grip strength was substantially higher in South-Asian participants (3.9 and 4.2 cases per 100 men and women, respectively) than in white participants (2.0 and 0.6 cases per 100 men and women, respectively). Attributable risk associated with low grip strength was also high in black men (4.3 cases) but not in black women (0.4 cases). Low strength is associated with a disproportionately large number of diabetes cases in South-Asian men and women and in black men. Trials are needed to determine whether interventions to improve strength in these groups could help reduce ethnic inequalities in diabetes prevalence. © 2017 Diabetes UK.

  5. Output control of da Vinci surgical system's surgical graspers.

    Science.gov (United States)

    Johnson, Paul J; Schmidt, David E; Duvvuri, Umamaheswar

    2014-01-01

    The number of robot-assisted surgeries performed with the da Vinci surgical system has increased significantly over the past decade. The articulating movements of the robotic surgical grasper are controlled by grip controls at the master console. The user interface has been implicated as one contributing factor in surgical grasping errors. The goal of our study was to characterize and evaluate the user interface of the da Vinci surgical system in controlling surgical graspers. An angular manipulator with force sensors was used to increment the grip control angle as grasper output angles were measured. Input force at the grip control was simultaneously measured throughout the range of motion. Pressure film was used to assess the maximum grasping force achievable with the endoscopic grasping tool. The da Vinci robot's grip control angular input has a nonproportional relationship with the grasper instrument output. The grip control mechanism presents an intrinsic resistant force to the surgeon's fingertips and provides no haptic feedback. The da Vinci Maryland graspers are capable of applying up to 5.1 MPa of local pressure. The angular and force input at the grip control of the da Vinci robot's surgical graspers is nonproportional to the grasper instrument's output. Understanding the true relationship of the grip control input to grasper instrument output may help surgeons understand how to better control the surgical graspers and promote fewer grasping errors. Copyright © 2014 Elsevier Inc. All rights reserved.

  6. One-Channel Surface Electromyography Decomposition for Muscle Force Estimation

    Directory of Open Access Journals (Sweden)

    Wentao Sun

    2018-05-01

    Full Text Available Estimating muscle force by surface electromyography (sEMG is a non-invasive and flexible way to diagnose biomechanical diseases and control assistive devices such as prosthetic hands. To estimate muscle force using sEMG, a supervised method is commonly adopted. This requires simultaneous recording of sEMG signals and muscle force measured by additional devices to tune the variables involved. However, recording the muscle force of the lost limb of an amputee is challenging, and the supervised method has limitations in this regard. Although the unsupervised method does not require muscle force recording, it suffers from low accuracy due to a lack of reference data. To achieve accurate and easy estimation of muscle force by the unsupervised method, we propose a decomposition of one-channel sEMG signals into constituent motor unit action potentials (MUAPs in two steps: (1 learning an orthogonal basis of sEMG signals through reconstruction independent component analysis; (2 extracting spike-like MUAPs from the basis vectors. Nine healthy subjects were recruited to evaluate the accuracy of the proposed approach in estimating muscle force of the biceps brachii. The results demonstrated that the proposed approach based on decomposed MUAPs explains more than 80% of the muscle force variability recorded at an arbitrary force level, while the conventional amplitude-based approach explains only 62.3% of this variability. With the proposed approach, we were also able to achieve grip force control of a prosthetic hand, which is one of the most important clinical applications of the unsupervised method. Experiments on two trans-radial amputees indicated that the proposed approach improves the performance of the prosthetic hand in grasping everyday objects.

  7. Sex Differences in the Level and Rate of Change of Physical Function and Grip Strength in the Danish 1905-Cohort Study

    DEFF Research Database (Denmark)

    Oksuzyan, Anna; Maier, Heiner; McGue, Matt

    2010-01-01

    OBJECTIVE: The study was conducted to examine sex differences in the initial level and rate of change in physical function and grip strength. METHOD: The baseline survey included 2,262 Danes born in 1905 and alive in 1998 and followed-up in 2000, 2003, and 2005. Hence, the authors fully used...... the power of having a cohort with multiple assessments in late life and virtually complete follow-up of lifespan (through December 2008). Latent growth curve modeling was used. RESULTS: Men had higher initial levels and rates of decline in strength score and grip strength. Lifespan was positively correlated...

  8. EEG-informed fMRI analysis during a hand grip task: estimating the relationship between EEG rhythms and the BOLD signal

    Directory of Open Access Journals (Sweden)

    Roberta eSclocco

    2014-04-01

    Full Text Available In the last decade, an increasing interest has arisen in investigating the relationship between the electrophysiological and hemodynamic measurements of brain activity, such as EEG and (BOLD fMRI. In particular, changes in BOLD have been shown to be associated with changes in the spectral profile of neural activity, rather than with absolute power. Concurrently, recent findings showed that different EEG rhythms are independently related to changes in the BOLD signal: therefore, it would be important to distinguish between the contributions of the different EEG rhythms to BOLD fluctuations when modeling the relationship between the two signals. Here we propose a method to perform EEG-informed fMRI analysis, in which the EEG regressors take into account both the changes in the spectral profile and the rhythms distinction. We applied it to EEG-fMRI data during a hand grip task in healthy subjects, and compared the results with those obtained by two existing models found in literature. Our results showed that the proposed method better captures the correlations between BOLD signal and EEG rhythms modulations, identifying task-related, well localized activated volumes. Furthermore, we showed that including among the regressors also EEG rhythms not primarily involved in the task enhances the performance of the analysis, even when only correlations with BOLD signal and specific EEG rhythms are explored.

  9. Hurricane Imaging Radiometer Wind Speed and Rain Rate Retrievals during the 2010 GRIP Flight Experiment

    Science.gov (United States)

    Sahawneh, Saleem; Farrar, Spencer; Johnson, James; Jones, W. Linwood; Roberts, Jason; Biswas, Sayak; Cecil, Daniel

    2014-01-01

    Microwave remote sensing observations of hurricanes, from NOAA and USAF hurricane surveillance aircraft, provide vital data for hurricane research and operations, for forecasting the intensity and track of tropical storms. The current operational standard for hurricane wind speed and rain rate measurements is the Stepped Frequency Microwave Radiometer (SFMR), which is a nadir viewing passive microwave airborne remote sensor. The Hurricane Imaging Radiometer, HIRAD, will extend the nadir viewing SFMR capability to provide wide swath images of wind speed and rain rate, while flying on a high altitude aircraft. HIRAD was first flown in the Genesis and Rapid Intensification Processes, GRIP, NASA hurricane field experiment in 2010. This paper reports on geophysical retrieval results and provides hurricane images from GRIP flights. An overview of the HIRAD instrument and the radiative transfer theory based, wind speed/rain rate retrieval algorithm is included. Results are presented for hurricane wind speed and rain rate for Earl and Karl, with comparison to collocated SFMR retrievals and WP3D Fuselage Radar images for validation purposes.

  10. PHYSIOLOGICAL RESPONSES DURING MATCHES AND PROFILE OF ELITE PENCAK SILAT EXPONENTS

    Directory of Open Access Journals (Sweden)

    Benedict Tan

    2002-12-01

    Full Text Available This is a descriptive, cross-sectional study describing the physiological responses during competitive matches and profile of elite exponents of an emerging martial art sport, pencak silat. Thirty exponents (21 males and 9 females were involved in the study. Match responses (i.e. heart rate (HR throughout match and capillary blood lactate concentration, [La], at pre-match and at the end of every round were obtained during actual competitive duels. Elite silat exponents' physiological attributes were assessed via anthropometry, vertical jump, isometric grip strength, maximal oxygen uptake, and the Wingate 30 s anaerobic test of the upper and lower body, in the laboratory. The match response data showed that silat competitors' mean HR was > 84% of estimated HR maximum and levels of [La] ranged from 6.7 - 18.7 mMol-1 during matches. This suggests that competitive silat matches are characterised by high aerobic and anaerobic responses. In comparison to elite taekwondo and judo athletes' physiological characteristics, elite silat exponents have lower aerobic fitness and grip strength, but greater explosive leg power (vertical jump. Generally, they also possessed a similar anaerobic capability in the lower but markedly inferior anaerobic capability in the upper body

  11. Effort, performance, and motivation: insights from robot-assisted training of human golf putting and rat grip strength.

    Science.gov (United States)

    Duarte, Jaime E; Gebrekristos, Berkenesh; Perez, Sergi; Rowe, Justin B; Sharp, Kelli; Reinkensmeyer, David J

    2013-06-01

    Robotic devices can modulate success rates and required effort levels during motor training, but it is unclear how this affects performance gains and motivation. Here we present results from training unimpaired humans in a virtual golf-putting task, and training spinal cord injured (SCI) rats in a grip strength task using robotically modulated success rates and effort levels. Robotic assistance in golf practice increased trainees feelings of competence, and, paradoxically, increased their sense effort, even though it had mixed effects on learning. Reducing effort during a grip strength training task led rats with SCI to practice the task more frequently. However, the more frequent practice of these rats did not cause them to exceed the strength gains achieved by rats that exercised less often at higher required effort levels. These results show that increasing success and decreasing effort with robots increases motivation, but has mixed effects on performance gains.

  12. alpha2 adrenoceptors are involved in the regulation of the gripping-induced immobility episodes in taiep rats.

    Science.gov (United States)

    Eguibar, José R; Cortés, Ma Del Carmen; Valencia, Jaime; Arias-Montaño, José A

    2006-10-01

    In 1989 Holmgren et al. (Holmgren et al. 1989 Lab Anim Sci 39:226-228) described a new mutant rat that developed a progressive motor disturbance during its lifespan. The syndrome is characterized by a tremor in the hind limbs followed by ataxia, episodes of tonic immobility, epilepsy, and paralysis. The acronym of these symptoms (taiep) became the name of this autosomic, recessive mutant rat. The taiep rats are neurological mutant animals with a hypomyelination, followed by a progressive demyelination process. At 7-8 months of age, taiep rats develop immobility episodes (IEs) characterized by a cortical desynchronization, associated with the theta rhythm in the hippocampus and changes of the nucal electromyogram (EMG), whose pattern is like rapid-eye-movement (REM) sleep. These rats also show an altered sleep pattern with an equal REM sleep distribution. This study analyzed therole of alpha(2) adrenoceptors in the expression of gripping-induced IEs in 8-month-old male taiep rats. The alpha(2) adrenoceptor agonists clonidine and xylacine increased the frequency of gripping-induced IEs whereas the alpha(2) antagonists yohimbine and idazoxandecreased or prevented such episodes. These findings correlate with the pharmacological observations in narcoleptic dogs and humans in which alpha(2) adrenergic mechanisms are involved in the modulation of cataplexy. Unexpectedly, the repetitive administration of clonidine resulted in jumping behavior, indicative of phasic activation of extensor musculature. Taken together, our results show that alpha(2) adrenoceptors are involved in the modulation in gripping-induced IEs and after the administration of several doses of clonidine produced phasic motor activation.

  13. Coefficient of friction of dry slash pine and southern red oak on three tension-grip facings

    Science.gov (United States)

    Truett J. Lemoine; Peter Koch

    1974-01-01

    A urethane material proved to have nine times higher static friction coefficient (0.9) than smooth steel (0.1) on radial and tangential wood surfaces pulled parallel to the grain. It is probably superior to 220-grit garnet paper or sand coatings for tension-grip facings in lumber testing machines.

  14. NBL Pistol Grip Tool for Underwater Training of Astronauts

    Science.gov (United States)

    Liszka, Michael; Ashmore, Matthew; Behnke, Mark; Smith, Walter; Waterman, Tod

    2011-01-01

    A document discusses a lightweight, functional mockup of the Pistol Grip Tool for use during underwater astronaut training. Previous training tools have caused shoulder injuries. This new version is more than 50 percent lighter [in water, weight is 2.4 lb (=1.1 kg)], and can operate for a six-hour training session after 30 minutes of prep for submersion. Innovations in the design include the use of lightweight materials (aluminum and Delrin(Registered TradeMark)), creating a thinner housing, and the optimization of internal space with the removal of as much excess material as possible. This reduces tool weight and maximizes buoyancy. Another innovation for this tool is the application of a vacuum that seats the Orings in place and has shown to be reliable in allowing underwater usage for up to six hours.

  15. Grips for testing of electrical characteristics of a specimen under a mechanical load

    Science.gov (United States)

    Briggs, Timothy; Loyola, Bryan

    2018-04-24

    Various technologies to facilitate coupled electrical and mechanical measurement of conductive materials are disclosed herein. A gripping device simultaneously holds a specimen in place and causes contact to be made between the specimen and a plurality of electrodes connected to an electrical measuring device. An electrical characteristic of the specimen is then measured while a mechanical load is applied to the specimen, and a relationship between the mechanical load and changes in the electrical characteristic can be identified.

  16. Wheelchair Mobility Performance enhancement by Changing Wheelchair Properties; What is the Effect of Grip, Seat Height and Mass?

    Science.gov (United States)

    van der Slikke, Rienk M A; de Witte, Annemarie M H; Berger, Monique A M; Bregman, Daan J J; Veeger, Dirk Jan H E J

    2018-02-12

    The purpose of this study was to provide insight in the effect of wheelchair settings on wheelchair mobility performance. Twenty elite wheelchair basketball athletes of low (n=10) and high classification (n=10), were tested in a wheelchair basketball directed field test. Athletes performed the test in their own wheelchair, which was modified for five additional conditions regarding seat height (high - low), mass (central - distributed) and grip. The previously developed, inertial sensor based wheelchair mobility performance monitor 1 was used to extract wheelchair kinematics in all conditions. Adding mass showed most effect on wheelchair mobility performance, with a reduced average acceleration across all activities. Once distributed, additional mass also reduced maximal rotational speed and rotational acceleration. Elevating seat height had effect on several performance aspects in sprinting and turning, whereas lowering seat height influenced performance minimally. Increased rim grip did not alter performance. No differences in response were evident between low and high classified athletes. The wheelchair mobility performance monitor showed sensitive to detect performance differences due to the small changes in wheelchair configuration made. Distributed additional mass had the most effect on wheelchair mobility performance, whereas additional grip had the least effect of conditions tested. Performance effects appear similar for both low and high classified athletes. Athletes, coaches and wheelchair experts are provided with insight in the performance effect of key wheelchair settings, and they are offered a proven sensitive method to apply in sports practice, in their search for the best wheelchair-athlete combination.

  17. Effects of Carpal Tunnel Syndrome on adaptation of multi-digit forces to object mass distribution for whole-hand manipulation

    Directory of Open Access Journals (Sweden)

    Zhang Wei

    2012-11-01

    Full Text Available Abstract Background Carpal tunnel syndrome (CTS is a compression neuropathy of the median nerve that results in sensorimotor deficits in the hand. Until recently, the effects of CTS on hand function have been studied using mostly two-digit grip tasks. The purpose of this study was to investigate the coordination of multi-digit forces as a function of object center of mass (CM during whole-hand grasping. Methods Fourteen CTS patients and age- and gender-matched controls were instructed to grasp, lift, hold, and release a grip device with five digits for seven consecutive lifts while maintaining its vertical orientation. The object CM was changed by adding a mass at different locations at the base of the object. We measured forces and torques exerted by each digit and object kinematics and analyzed modulation of these variables to object CM at object lift onset and during object hold. Our task requires a modulation of digit forces at and after object lift onset to generate a compensatory moment to counteract the external moment caused by the added mass and to minimize object tilt. Results We found that CTS patients learned to generate a compensatory moment and minimized object roll to the same extent as controls. However, controls fully exploited the available degrees of freedom (DoF in coordinating their multi-digit forces to generate a compensatory moment, i.e., digit normal forces, tangential forces, and the net center of pressure on the finger side of the device at object lift onset and during object hold. In contrast, patients modulated only one of these DoFs (the net center of pressure to object CM by modulating individual normal forces at object lift onset. During object hold, however, CTS patients were able to modulate digit tangential force distribution to object CM. Conclusions Our findings suggest that, although CTS did not affect patients’ ability to perform our manipulation task, it interfered with the modulation of specific grasp

  18. Limited Investigation of the Effects of Elevator Rate Limiting and Stick Dynamics on Longitudinal Pilot Induced Oscillations (HAVE GRIP)

    National Research Council Canada - National Science Library

    Peters, Patrick

    1996-01-01

    This report presents the results of the HAVE GRIP flight test program. This program performed a limited investigation of the effects of stick dynamics and elevator rate limiting on longitudinal pilot induced oscillations (PIOs...

  19. Fuel assembly gripping device using self-locking mechanism

    Energy Technology Data Exchange (ETDEWEB)

    Lee, G. M.; Choi, S.; Kim, K. S.; Kim, T. W.; Jeong, K. H.; Park, K. B.; Chang, M. H

    1999-07-01

    This report presents an actuating principles and structure for two kind of the fuel assembly gripping devices (Gripper-A, B) developed for SMART. The main components of these grippers are push bundle, rotation bundle, upper guide tube and chuck assembly. The rope attached to winch system on moving cask hangs gripper's push bundle. Due to a down-and-up operation of winch system, the push bundle pushes crown teeth shaped rotation bundle and then it is pushed down and rotated counter clockwise. The push-and-pull sequential operation of push bundle makes the rotation bundle is pushed, rotated and returned, moreover it makes the chuck assembly is expanded or shrunk. The expansion and shrinkage motion of chuck assembly makes the gripper latch and release the fuel assembly. Gripper-A suits for the handling of the fuel assembly with square shaped latching hole. Otherwise Gripper-B suits for a circular shaped latching hole. (author). 5 refs., 20 figs.

  20. Fuel assembly gripping device using self-locking mechanism

    International Nuclear Information System (INIS)

    Lee, G. M.; Choi, S.; Kim, K. S.; Kim, T. W.; Jeong, K. H.; Park, K. B.; Chang, M. H.

    1999-07-01

    This report presents an actuating principles and structure for two kind of the fuel assembly gripping devices (Gripper-A, B) developed for SMART. The main components of these grippers are push bundle, rotation bundle, upper guide tube and chuck assembly. The rope attached to winch system on moving cask hangs gripper's push bundle. Due to a down-and-up operation of winch system, the push bundle pushes crown teeth shaped rotation bundle and then it is pushed down and rotated counter clockwise. The push-and-pull sequential operation of push bundle makes the rotation bundle is pushed, rotated and returned, moreover it makes the chuck assembly is expanded or shrunk. The expansion and shrinkage motion of chuck assembly makes the gripper latch and release the fuel assembly. Gripper-A suits for the handling of the fuel assembly with square shaped latching hole. Otherwise Gripper-B suits for a circular shaped latching hole. (author). 5 refs., 20 figs

  1. Vitamin D status predicts hand-grip strength in young adult women living in Auckland, New Zealand.

    Science.gov (United States)

    von Hurst, P R; Conlon, C; Foskett, A

    2013-07-01

    The identification of the vitamin D receptor (VDR) in skeletal muscle tissue and research in muscle strength and development in VDR-null mice confirms a role for vitamin D in muscle function. The relationship between muscle strength and vitamin D status has been explored to some degree in older populations with regard to fall prevention, but there has been very little research in younger adults. This cross-sectional study considered the predictors of muscle strength in 137 young women (19-29 years) living in New Zealand. The following measurements were taken in the latter months of winter: plasma 25OHD, dominant (HGD) and non-dominant hand-grip (HGND) strength (hand-grip dynamometer), counter measure jump, and recreational physical activity (RPA) assessed from a recent physical activity questionnaire (RPAQ). Dietary intake was measured with a four-day food diary, and body composition using air displacement plethysmography. This was a relatively inactive group of women; total RPA ranged from 0 to 3.93h per week, mean (SD) 0.86(0.74) h, approximately 50% comprised outdoor activities. Mean 25OHD was 54(28)nmol/l, HGD and HGND were significantly different (t=6.049, pstrength as the dependent variable (Model R(2)=0.11, p=0.001 non-dominant, R(2)=0.13, pstrength and serum 25OHD, and when each were adjusted to remove this association, 25OHD accounted for 4.3% of HGND and 4.5% of HGD. These results suggest that vitamin D status does have a small but significant association with hand-grip strength in this group of young women. Further investigation in this age group with a randomised controlled trial is justified. This article is part of a Special Issue entitled 'Vitamin D Workshop'. Copyright © 2012 Elsevier Ltd. All rights reserved.

  2. Quantitative dopant profiling in semiconductors. A new approach to Kelvin probe force microscopy

    Energy Technology Data Exchange (ETDEWEB)

    Baumgart, Christine

    2012-07-01

    Failure analysis and optimization of semiconducting devices request knowledge of their electrical properties. To meet the demands of today's semiconductor industry, an electrical nanometrology technique is required which provides quantitative information about the doping profile and which enables scans with a lateral resolution in the sub-10 nm range. In the presented work it is shown that Kelvin probe force microscopy (KPFM) is a very promising electrical nanometrology technique to face this challenge. The technical and physical aspects of KPFM measurements on semiconductors required for the correct interpretation of the detected KPFM bias are discussed. A new KPFM model is developed which enables the quantitative correlation between the probed KPFM bias and the dopant concentration in the investigated semiconducting sample. Quantitative dopant profiling by means of the new KPFM model is demonstrated by the example of differently structured, n- and p-type doped silicon. Additionally, the transport of charge carriers during KPFM measurements, in particular in the presence of intrinsic electric fields due to vertical and horizontal pn junctions as well as due to surface space charge regions, is discussed. Detailed investigations show that transport of charge carriers in the semiconducting sample is a crucial aspect and has to be taken into account when aiming for a quantitative evaluation of the probed KPFM bias.

  3. Development of Hand Grip Assistive Device Control System for Old People through Electromyography (EMG Signal Acquisitions

    Directory of Open Access Journals (Sweden)

    Khamis Herman

    2017-01-01

    Full Text Available The hand grip assistive device is a glove to assist old people who suffer from hand weakness in their daily life activities. The device earlier control system only use simple on and off switch. This required old people to use both hand to activate the device. The new control system of the hand grip assistive device was developed to allow single hand operation for old people. New control system take advantages of electromyography (EMG and flex sensor which was implemented to the device. It was programmed into active and semi-active mode operation. EMG sensors were placed on the forearm to capture EMG signal of Flexor Digitorum Profundus muscle to activate the device. Flex sensor was used to indicate the finger position and placed on top of the finger. The signal from both sensors then used to control the device. The new control system allowed single hand operation and designed to prevent user from over depended on the device by activating it through moving their fingers.

  4. Short-Term Effects of Whole-Body Vibration Combined with Task-Related Training on Upper Extremity Function, Spasticity, and Grip Strength in Subjects with Poststroke Hemiplegia: A Pilot Randomized Controlled Trial.

    Science.gov (United States)

    Lee, Jung-Sun; Kim, Chang-Yong; Kim, Hyeong-Dong

    2016-08-01

    The aim of this study was to determine the effect of whole-body vibration training combined with task-related training on arm function, spasticity, and grip strength in subjects with poststroke hemiplegia. Forty-five subjects with poststroke were randomly allocated to 3 groups, each with 15 subjects as follows: control group, whole-body vibration group, and whole-body vibration plus task-related training group. Outcome was evaluated by clinical evaluation and measurements of the grip strength before and 4 weeks after intervention. Our results show that there was a significantly greater increase in the Fugl-Meyer scale, maximal grip strength of the affected hand, and grip strength normalized to the less affected hand in subjects undergoing the whole-body vibration training compared with the control group after the test. Furthermore, there was a significantly greater increase in the Wolf motor function test and a decrease in the modified Ashworth spasticity total scores in subjects who underwent whole-body vibration plus task-related training compared with those in the other 2 groups after the test. The findings indicate that the use of whole-body vibration training combined with task-related training has more benefits on the improvement of arm function, spasticity, and maximal grip strength than conventional upper limb training alone or with whole-body vibration in people with poststroke hemiplegia.

  5. Influence of the gripping fixture on the modified compact tension test results: Evaluation of the experiments on cylindrical concrete specimens

    Czech Academy of Sciences Publication Activity Database

    Holušová, T.; Lozano, M.; Canteli, A.; Komárková, T.; Kocáb, D.; Seitl, Stanislav

    2015-01-01

    Roč. 15, č. 2 (2015) ISSN 1804-4824 Institutional support: RVO:68081723 Keywords : Modified compact tension test * fracture parametr * Cementitious composites * Aramis measurement * grips Subject RIV: JL - Materials Fatigue, Friction Mechanics

  6. Constraints on grip selection in hemiparetic cerebral palsy: Effects of lesional side, end-point accuracy and context.

    NARCIS (Netherlands)

    Steenbergen, B.; Meulenbroek, R.G.J.; Rosenbaum, D.A.

    2004-01-01

    This study was concerned with the selection criteria used for grip planning in adolescents with left or right hemiparetic cerebral palsy. In the first experiment participants picked up a pencil and placed the tip in a pre-defined target region. We varied the size of the target to test the hypothesis

  7. EyeGrip: Detecting Targets in a Series of Uni-directional Moving Objects Using Optokinetic Nystagmus Eye Movements

    DEFF Research Database (Denmark)

    Jalaliniya, Shahram; Mardanbeigi, Diako

    2016-01-01

    computers. In this paper, we demonstrate the rich capabilities of EyeGrip with two example applications: 1) a mind reading game, and 2) a picture selection system. Our study shows that by selecting an appropriate speed and maximum number of visible images in the screen the proposed method can be used...

  8. Factors influencing power hand tool fastening accuracy and reaction forces.

    Science.gov (United States)

    Radwin, Robert G; Chourasia, Amrish O; Howery, Robert S; Fronczak, Frank J; Yen, Thomas Y; Subedi, Yashpal; Sesto, Mary E

    2014-06-01

    A laboratory study investigated the relationship between power hand tool and task-related factors affecting threaded fastener torque accuracy and associated handle reaction force. We previously developed a biodynamic model to predict handle reaction forces. We hypothesized that torque accuracy was related to the same factors that affect operator capacity to react against impulsive tool forces, as predicted by the model. The independent variables included tool (pistol grip on a vertical surface, right angle on a horizontal surface), fastener torque rate (hard, soft), horizontal distance (30 cm and 60 cm), and vertical distance (80 cm, 110 cm, and 140 cm). Ten participants (five male and five female) fastened 12 similar bolts for each experimental condition. Average torque error (audited - target torque) was affected by fastener torque rate and operator position. Torque error decreased 33% for soft torque rates, whereas handle forces greatly increased (170%). Torque error also decreased for the far horizontal distance 7% to 14%, when vertical distance was in the middle or high, but handle force decreased slightly 3% to 5%. The evidence suggests that although both tool and task factors affect fastening accuracy, they each influence handle reaction forces differently. We conclude that these differences are attributed to different parameters each factor influences affecting the dynamics of threaded faster tool operation. Fastener torque rate affects the tool dynamics, whereas posture affects the spring-mass-damping biodynamic properties of the human operator. The prediction of handle reaction force using an operator biodynamic model may be useful for codifying complex and unobvious relationships between tool and task factors for minimizing torque error while controlling handle force.

  9. Geometry, penetration force, and cutting profile of different 23-gauge trocars systems for pars plana vitrectomy.

    Science.gov (United States)

    Meyer, Carsten H; Kaymak, Hakan; Liu, Zengping; Saxena, Sandeep; Rodrigues, Eduardo B

    2014-11-01

    To investigate the geometry, penetration force, and cutting profile of 23-gauge trocar systems for pars plana vitrectomy based on their grinding methods in a standardized laboratory setting. In this experimental study, Eleven different commercially available 23-gauge sclerotomy trocar systems were divided into 4 groups according to their needle grinding and deburring: "back" bevel, "spear" bevel, "lancet" bevel, and "spatula" bevel. The normative geometrical data of the trocar systems were systematically analyzed according to nomenclature ISO 7864 and ISO 9626. Force to penetrate a 0.4-mm thick polyurethane foil was measured by a Penetrometer, when the trocar needle was piercing, cutting, and sliding through the foil at different defined loading phases and plotted as a load-displacement diagram. Magnified images of the consecutive cut were taken under a microscope after the entire penetration through the foil. Three physicians used all trocar systems in a masked fashion on human sclera to evaluate the manual penetration force in 30° and 90°. The mean outer diameter of the trocar systems was 0.630 ± 0.009 mm, and the mean outer diameter of the trocars was 0.750 ± 0.013 mm. The mean point length was 3.11 ± 0.49 mm, and the mean length of the bevel was 1.46 ± 0.23 mm. The primary bevel angle was 10.75 ± 0.41°, and the secondary bevel angle was 65.9 ± 42.56°. The piercing forces of the back bevel and spear-pointed trocars/needles were at the same level (0.087 ± 0.028 N). The lancet-pointed needle had remarkable low piercing and cutting forces with 0.41 N (range, 0.35-0.47 N). The spatula bevel tip showed the highest penetration piercing force with 1.6 N (range, 1.59-1.73 N). The back bevel systems induced frequently triangular-shaped incisions, with two nearly rectangular cuts of short length. The spear bevels produced a regular characteristic linear cut. Especially, the lancet blade created straight cut with a linear wound apposition. Spatula trocar systems

  10. Design and Analysis of a Fibre-Shaped Micro-Actuator for Robotic Gripping

    Directory of Open Access Journals (Sweden)

    Alberto Borboni

    2013-03-01

    Full Text Available A prototype of an automatic micropositioning system was developed. This prototype uses a shape memory alloy (SMA actuator, a dedicated PI controller and a piece of software to command a desired motion profile for the actuator. The proposed micropositioning system is characterized by a 4 mm stroke, a 1 μm resolution and a 70 g nominal force and can be commanded directly from a personal computer and without human retroaction. The closed loop positioning resolution (1 μm is obtained in spite of inaccurate system behaviour during its movement.

  11. Review and Evaluation of Hand–Arm Coordinate Systems for Measuring Vibration Exposure, Biodynamic Responses, and Hand Forces

    Directory of Open Access Journals (Sweden)

    Ren G. Dong

    2015-09-01

    Full Text Available The hand coordinate systems for measuring vibration exposures and biodynamic responses have been standardized, but they are not actually used in many studies. This contradicts the purpose of the standardization. The objectives of this study were to identify the major sources of this problem, and to help define or identify better coordinate systems for the standardization. This study systematically reviewed the principles and definition methods, and evaluated typical hand coordinate systems. This study confirms that, as accelerometers remain the major technology for vibration measurement, it is reasonable to standardize two types of coordinate systems: a tool-based basicentric (BC system and an anatomically based biodynamic (BD system. However, these coordinate systems are not well defined in the current standard. Definition of the standard BC system is confusing, and it can be interpreted differently; as a result, it has been inconsistently applied in various standards and studies. The standard hand BD system is defined using the orientation of the third metacarpal bone. It is neither convenient nor defined based on important biological or biodynamic features. This explains why it is rarely used in practice. To resolve these inconsistencies and deficiencies, we proposed a revised method for defining the realistic handle BC system and an alternative method for defining the hand BD system. A fingertip-based BD system for measuring the principal grip force is also proposed based on an important feature of the grip force confirmed in this study.

  12. Review and Evaluation of Hand–Arm Coordinate Systems for Measuring Vibration Exposure, Biodynamic Responses, and Hand Forces

    Science.gov (United States)

    Dong, Ren G.; Sinsel, Erik W.; Welcome, Daniel E.; Warren, Christopher; Xu, Xueyan S.; McDowell, Thomas W.; Wu, John Z.

    2015-01-01

    The hand coordinate systems for measuring vibration exposures and biodynamic responses have been standardized, but they are not actually used in many studies. This contradicts the purpose of the standardization. The objectives of this study were to identify the major sources of this problem, and to help define or identify better coordinate systems for the standardization. This study systematically reviewed the principles and definition methods, and evaluated typical hand coordinate systems. This study confirms that, as accelerometers remain the major technology for vibration measurement, it is reasonable to standardize two types of coordinate systems: a tool-based basicentric (BC) system and an anatomically based biodynamic (BD) system. However, these coordinate systems are not well defined in the current standard. Definition of the standard BC system is confusing, and it can be interpreted differently; as a result, it has been inconsistently applied in various standards and studies. The standard hand BD system is defined using the orientation of the third metacarpal bone. It is neither convenient nor defined based on important biological or biodynamic features. This explains why it is rarely used in practice. To resolve these inconsistencies and deficiencies, we proposed a revised method for defining the realistic handle BC system and an alternative method for defining the hand BD system. A fingertip-based BD system for measuring the principal grip force is also proposed based on an important feature of the grip force confirmed in this study. PMID:26929824

  13. Review and Evaluation of Hand-Arm Coordinate Systems for Measuring Vibration Exposure, Biodynamic Responses, and Hand Forces.

    Science.gov (United States)

    Dong, Ren G; Sinsel, Erik W; Welcome, Daniel E; Warren, Christopher; Xu, Xueyan S; McDowell, Thomas W; Wu, John Z

    2015-09-01

    The hand coordinate systems for measuring vibration exposures and biodynamic responses have been standardized, but they are not actually used in many studies. This contradicts the purpose of the standardization. The objectives of this study were to identify the major sources of this problem, and to help define or identify better coordinate systems for the standardization. This study systematically reviewed the principles and definition methods, and evaluated typical hand coordinate systems. This study confirms that, as accelerometers remain the major technology for vibration measurement, it is reasonable to standardize two types of coordinate systems: a tool-based basicentric (BC) system and an anatomically based biodynamic (BD) system. However, these coordinate systems are not well defined in the current standard. Definition of the standard BC system is confusing, and it can be interpreted differently; as a result, it has been inconsistently applied in various standards and studies. The standard hand BD system is defined using the orientation of the third metacarpal bone. It is neither convenient nor defined based on important biological or biodynamic features. This explains why it is rarely used in practice. To resolve these inconsistencies and deficiencies, we proposed a revised method for defining the realistic handle BC system and an alternative method for defining the hand BD system. A fingertip-based BD system for measuring the principal grip force is also proposed based on an important feature of the grip force confirmed in this study.

  14. Memory-guided force control in healthy younger and older adults.

    Science.gov (United States)

    Neely, Kristina A; Samimy, Shaadee; Blouch, Samantha L; Wang, Peiyuan; Chennavasin, Amanda; Diaz, Michele T; Dennis, Nancy A

    2017-08-01

    Successful performance of a memory-guided motor task requires participants to store and then recall an accurate representation of the motor goal. Further, participants must monitor motor output to make adjustments in the absence of visual feedback. The goal of this study was to examine memory-guided grip force in healthy younger and older adults and compare it to performance on behavioral tasks of working memory. Previous work demonstrates that healthy adults decrease force output as a function of time when visual feedback is not available. We hypothesized that older adults would decrease force output at a faster rate than younger adults, due to age-related deficits in working memory. Two groups of participants, younger adults (YA: N = 32, mean age 21.5 years) and older adults (OA: N = 33, mean age 69.3 years), completed four 20-s trials of isometric force with their index finger and thumb, equal to 25% of their maximum voluntary contraction. In the full-vision condition, visual feedback was available for the duration of the trial. In the no vision condition, visual feedback was removed for the last 12 s of each trial. Participants were asked to maintain constant force output in the absence of visual feedback. Participants also completed tasks of word recall and recognition and visuospatial working memory. Counter to our predictions, when visual feedback was removed, younger adults decreased force at a faster rate compared to older adults and the rate of decay was not associated with behavioral performance on tests of working memory.

  15. Force-independent distribution of correlated neural inputs to hand muscles during three-digit grasping.

    Science.gov (United States)

    Poston, Brach; Danna-Dos Santos, Alessander; Jesunathadas, Mark; Hamm, Thomas M; Santello, Marco

    2010-08-01

    The ability to modulate digit forces during grasping relies on the coordination of multiple hand muscles. Because many muscles innervate each digit, the CNS can potentially choose from a large number of muscle coordination patterns to generate a given digit force. Studies of single-digit force production tasks have revealed that the electromyographic (EMG) activity scales uniformly across all muscles as a function of digit force. However, the extent to which this finding applies to the coordination of forces across multiple digits is unknown. We addressed this question by asking subjects (n = 8) to exert isometric forces using a three-digit grip (thumb, index, and middle fingers) that allowed for the quantification of hand muscle coordination within and across digits as a function of grasp force (5, 20, 40, 60, and 80% maximal voluntary force). We recorded EMG from 12 muscles (6 extrinsic and 6 intrinsic) of the three digits. Hand muscle coordination patterns were quantified in the amplitude and frequency domains (EMG-EMG coherence). EMG amplitude scaled uniformly across all hand muscles as a function of grasp force (muscle x force interaction: P = 0.997; cosines of angle between muscle activation pattern vector pairs: 0.897-0.997). Similarly, EMG-EMG coherence was not significantly affected by force (P = 0.324). However, coherence was stronger across extrinsic than that across intrinsic muscle pairs (P = 0.0039). These findings indicate that the distribution of neural drive to multiple hand muscles is force independent and may reflect the anatomical properties or functional roles of hand muscle groups.

  16. Changes in pain, dysfunction, and grip strength of patients with acute lateral epicondylitis caused by frequency of physical therapy: a randomized controlled trial.

    Science.gov (United States)

    Lee, Soyoung; Ko, Youngjun; Lee, Wanhee

    2014-07-01

    [Purpose] The purpose of this study was to investigate the changes in pain, dysfunction, and grip strength of patients with acute lateral epicondylitis and to suggest the appropriate treatment frequency and period. [Subjects] The subjects were divided into three: 2 days per week group (n=12), 3 days per week group (n=15), and 6 days per week group (n=13). [Methods] All groups received conventional physical therapy for 40 minutes and therapeutic exercises for 20 minutes per session during 6 weeks. The outcome measurements were the visual analogue scale (VAS), Patient-Rated Tennis Elbow Evaluation (PRTEE), and grip strength. [Results] The results of this study were as follows: at 3 weeks, there were no significant differences in VAS and PRTEE in the 3 groups, but at 6 weeks, 6 days per week group significantly decreased these two outcomes. Grip strength was significantly increased in 3 and 6 days per week groups at 6 weeks. [Conclusion] In conclusion, physical therapy is needed 3 days per week for 3 weeks in patients with acute lateral epicondylitis. After 3 weeks, 6 days per week is the most effective treatment frequency.

  17. Laterality and grip strength influence hand bone micro-architecture in modern humans, an HRpQCT study.

    Science.gov (United States)

    Reina, Nicolas; Cavaignac, Etienne; Trousdale, William H; Laffosse, Jean-Michel; Braga, José

    2017-06-01

    It is widely hypothesized that mechanical loading, specifically repetitive low-intensity tasks, influences the inner structure of cancellous bone. As such, there is likely a relationship between handedness and bone morphology. The aim of this study is to determine patterns in trabecular bone between dominant and non-dominant hands in modern humans. Seventeen healthy patients between 22 and 32 years old were included in the study. Radial carpal bones (lunate, capitate, scaphoid, trapezium, trapezoid, 1st, 2nd and 3rd metacarpals) were analyzed with high-resolution micro-computed tomography. Additionally, crush and pinch grip were recorded. Factorial analysis indicated that bone volume ratio, trabeculae number (Tb.N), bone surface to volume ratio (BS.BV), body weight, stature and crush grip were all positively correlated with principal components 1 and 2 explaining 78.7% of the variance. Volumetric and trabecular endostructural parameters (BV/TV, BS/BV or Tb.Th, Tb.N) explain the observed inter-individual variability better than anthropometric or clinical parameters. Factors analysis regressions showed correlations between these parameters and the dominant side for crush strength for the lunate (r 2 = 0.640, P modern human wrist. © 2017 Anatomical Society.

  18. Customization, control, and characterization of a commercial haptic device for high-fidelity rendering of weak forces.

    Science.gov (United States)

    Gurari, Netta; Baud-Bovy, Gabriel

    2014-09-30

    The emergence of commercial haptic devices offers new research opportunities to enhance our understanding of the human sensory-motor system. Yet, commercial device capabilities have limitations which need to be addressed. This paper describes the customization of a commercial force feedback device for displaying forces with a precision that exceeds the human force perception threshold. The device was outfitted with a multi-axis force sensor and closed-loop controlled to improve its transparency. Additionally, two force sensing resistors were attached to the device to measure grip force. Force errors were modeled in the frequency- and time-domain to identify contributions from the mass, viscous friction, and Coulomb friction during open- and closed-loop control. The effect of user interaction on system stability was assessed in the context of a user study which aimed to measure force perceptual thresholds. Findings based on 15 participants demonstrate that the system maintains stability when rendering forces ranging from 0-0.20 N, with an average maximum absolute force error of 0.041 ± 0.013 N. Modeling the force errors revealed that Coulomb friction and inertia were the main contributors to force distortions during respectively slow and fast motions. Existing commercial force feedback devices cannot render forces with the required precision for certain testing scenarios. Building on existing robotics work, this paper shows how a device can be customized to make it reliable for studying the perception of weak forces. The customized and closed-loop controlled device is suitable for measuring force perceptual thresholds. Copyright © 2014 Elsevier B.V. All rights reserved.

  19. The Effect of Repetitive Rhythmic Precision Grip Task-Oriented Rehabilitation in Chronic Stroke Patients: A Pilot Study

    Science.gov (United States)

    Dispa, Delphine; Lejeune, Thierry; Thonnard, Jean-Louis

    2013-01-01

    Most chronic stroke patients present with difficulty in the manipulation of objects. The aim of this study was to test whether an intensive program of precision grip training could improve hand functioning of patients at more than 6 months after a stroke. This was a cross-over study; hence, at inclusion, the patients were randomly divided into two…

  20. Interobserver reproducibility of the assessment of severity of complaints, grip strength, and pressure pain threshold in patients with lateral epicondylitis.

    NARCIS (Netherlands)

    Smidt, N.; Windt, A. van der; Assendelft, W.J.; Mourits, A.J.; Devillé, W.L.; Winter, F. de; Bouter, L.M.

    2002-01-01

    Objective: To evaluate the interobserver reproducibility of the assessment of severity of complaints, grip strength, and pressure pain threshold in patients with lateral epicondylitis in primary care. Design: Two physiotherapists assessed independently, and in randomized order, the severity of

  1. Interobserver reproducibility of the assessment of severity of complaints, grip strength, and pressure pain threshold in patients with lateral epicondylitis

    NARCIS (Netherlands)

    Smidt, N; van der Windt, DA; Assendelft, WJ; Mourits, AJ; Deville, WL; de Winter, AF; Bouter, LM

    Objective: To evaluate the interobserver reproducibility of the assessment of severity of complaints, grip strength, and pressure pain threshold in patients with lateral epicondylitis in primary care. Design: Two physiotherapists assessed independently, and in randomized order, the severity of

  2. Power-assistive finger exoskeleton with a palmar opening at the fingerpad.

    Science.gov (United States)

    Heo, Pilwon; Kim, Jung

    2014-11-01

    This paper presents a powered finger exoskeleton with an open fingerpad, named the Open Fingerpad eXoskeleton (OFX). The palmar opening at the fingerpad allows for direct contact between the user's fingerpad and objects in order to make use of the wearer's own tactile sensation for dexterous manipulation. Lateral side walls at the end of the OFX's index finger module are equipped with custom load cells for estimating the wearer's pinch grip force. A pneumatic cylinder generates assistance force, which is determined according to the estimated pinch grip force. The OFX transmits the assistance force directly to the objects without exerting pressure on the wearer's finger. The advantage of the OFX over an exoskeleton with a closed fingerpad was validated experimentally. During static and dynamic manipulation of a test object, the OFX exhibited a lower safety margin than the closed exoskeleton, indicating a higher ability to adjust the grip force within an appropriate range. Furthermore, the benefit of force assistance in reducing the muscular burden was observed in terms of muscle fatigue during a static pinch grip. The median frequency (MDF) of the surface electromyography (sEMG) signal from the first dorsal interosseous (FDI) muscle displayed a lower reduction rate for the assisted condition, indicating a lower accumulation rate of muscle fatigue.

  3. A device for testing the dynamic performance of in situ force plates.

    Science.gov (United States)

    East, Rebecca H; Noble, Jonathan J; Arscott, Richard A; Shortland, Adam P

    2017-09-01

    Force plates are often incorporated into motion capture systems for the calculation of joint kinetic variables and other data. This project aimed to create a system that could be used to check the dynamic performance of force plate in situ. The proposed solution involved the design and development of an eccentrically loaded wheel mounted on a weighted frame. The frame was designed to hold a wheel mounted in two orthogonal positions. The wheel was placed on the force plate and spun. A VICON™ motion analysis system captured the positional data of the markers placed around the rim of the wheel which was used to create a simulated force profile, and the force profile was dependent on spin speed. The root mean square error between the simulated force profile and the force plate measurement was calculated. For nine trials conducted, the root mean square error between the two simultaneous measures of force was calculated. The difference between the force profiles in the x- and y-directions is approximately 2%. The difference in the z-direction was under 0.5%. The eccentrically loaded wheel produced a predictable centripetal force in the plane of the wheel which varied in direction as the wheel was spun and magnitude dependent on the spin speed. There are three important advantages to the eccentrically loaded wheel: (1) it does not rely on force measurements made from other devices, (2) the tests require only 15 min to complete per force plate and (3) the forces exerted on the plate are similar to those of paediatric gait.

  4. Grounding by Attention Simulation in Peripersonal Space: Pupils Dilate to Pinch Grip But Not Big Size Nominal Classifier.

    Science.gov (United States)

    Lobben, Marit; Bochynska, Agata

    2018-03-01

    Grammatical categories represent implicit knowledge, and it is not known if such abstract linguistic knowledge can be continuously grounded in real-life experiences, nor is it known what types of mental states can be simulated. A former study showed that attention bias in peripersonal space (PPS) affects reaction times in grammatical congruency judgments of nominal classifiers, suggesting that simulated semantics may include reenactment of attention. In this study, we contrasted a Chinese nominal classifier used with nouns denoting pinch grip objects with a classifier for nouns with big object referents in a pupil dilation experiment. Twenty Chinese native speakers read grammatical and ungrammatical classifier-noun combinations and made grammaticality judgment while their pupillary responses were measured. It was found that their pupils dilated significantly more to the pinch grip classifier than to the big object classifier, indicating attention simulation in PPS. Pupil dilations were also significantly larger with congruent trials on the whole than in incongruent trials, but crucially, congruency and classifier semantics were independent of each other. No such effects were found in controls. Copyright © 2017 Cognitive Science Society, Inc.

  5. Physiological, Nutritional and Performance Profiles of Brazilian Jiu-Jitsu Athletes

    Directory of Open Access Journals (Sweden)

    Andreato Leonardo V

    2016-12-01

    Full Text Available This study analysed the physiological, nutritional and performance profiles of athletes practicing Brazilian jiu-jitsu. To this end, 15 athletes that practiced Brazilian jiu-jitsu (aged: 28 ± 5 years; 8 brown belts and 7 black belts; training experience: 11 ± 4 years underwent anthropometric measurements (body composition and somatotype, dietary evaluation (24 h recall and physical fitness tests (movement time, dynamometer handgrip, kimono grip strength, vertical jump and sit-and-reach tests. The athletes had 12.7 ± 4.8% of body fat, 59.2 ± 5.0% of muscle mass and their somatotype was dominated by the mesomorphic component (5.3 ± 2.0, followed by endomorphic (3.7 ± 1.5 and ectomorphic (1.4 ± 0.9 components. Nutritional assessment suggested a diet consisting of 54 ± 7% of carbohydrates, 19 ± 4% of protein and 27 ± 6% of lipids. Movement time on the handgrip tests was 0.42 ± 0.05 s, for handgrip strength, 53 ± 7 kgf was found for the dominant hand and 50 ± 9 kgf for the non-dominant hand. For the countermovement jump, the jiu-jitsu athletes reached 41 ± 5 cm. Athletes remained 30 ± 14 s in the maximum static suspension test gripping a kimono, and reached 27 ± 8 cm in the sit-and-reach test. Overall the sample presented average levels of body fat, elevated muscle mass and a predominantly mesomorphic somatotype. Diet was generally poor, with low carbohydrate intake, high protein intake and adequate lipid intake. Maximum isometric handgrip strength was consistent with observations of other athletes in this sport discipline. However, the performance in the maximum static suspension test gripping a kimono was lower than in other Brazilian jiu-jitsu athletes. Movement time was comparable and lower body muscle power was worse compared to athletes in similar sports. Additionally, flexibility was rated as poor.

  6. Physiological, Nutritional and Performance Profiles of Brazilian Jiu-Jitsu Athletes.

    Science.gov (United States)

    Andreato, Leonardo V; Santos, Jonatas Fs; Esteves, João Vdc; Panissa, Valeria Lg; Julio, Ursula F; Franchini, Emerson

    2016-12-01

    This study analysed the physiological, nutritional and performance profiles of athletes practicing Brazilian jiu-jitsu. To this end, 15 athletes that practiced Brazilian jiu-jitsu (aged: 28 ± 5 years; 8 brown belts and 7 black belts; training experience: 11 ± 4 years) underwent anthropometric measurements (body composition and somatotype), dietary evaluation (24 h recall) and physical fitness tests (movement time, dynamometer handgrip, kimono grip strength, vertical jump and sit-and-reach tests). The athletes had 12.7 ± 4.8% of body fat, 59.2 ± 5.0% of muscle mass and their somatotype was dominated by the mesomorphic component (5.3 ± 2.0), followed by endomorphic (3.7 ± 1.5) and ectomorphic (1.4 ± 0.9) components. Nutritional assessment suggested a diet consisting of 54 ± 7% of carbohydrates, 19 ± 4% of protein and 27 ± 6% of lipids. Movement time on the handgrip tests was 0.42 ± 0.05 s, for handgrip strength, 53 ± 7 kgf was found for the dominant hand and 50 ± 9 kgf for the non-dominant hand. For the countermovement jump, the jiu-jitsu athletes reached 41 ± 5 cm. Athletes remained 30 ± 14 s in the maximum static suspension test gripping a kimono, and reached 27 ± 8 cm in the sit-and-reach test. Overall the sample presented average levels of body fat, elevated muscle mass and a predominantly mesomorphic somatotype. Diet was generally poor, with low carbohydrate intake, high protein intake and adequate lipid intake. Maximum isometric handgrip strength was consistent with observations of other athletes in this sport discipline. However, the performance in the maximum static suspension test gripping a kimono was lower than in other Brazilian jiu-jitsu athletes. Movement time was comparable and lower body muscle power was worse compared to athletes in similar sports. Additionally, flexibility was rated as poor.

  7. Free energy profiles of cocaine esterase-cocaine binding process by molecular dynamics and potential of mean force simulations.

    Science.gov (United States)

    Zhang, Yuxin; Huang, Xiaoqin; Han, Keli; Zheng, Fang; Zhan, Chang-Guo

    2016-11-25

    The combined molecular dynamics (MD) and potential of mean force (PMF) simulations have been performed to determine the free energy profile of the CocE)-(+)-cocaine binding process in comparison with that of the corresponding CocE-(-)-cocaine binding process. According to the MD simulations, the equilibrium CocE-(+)-cocaine binding mode is similar to the CocE-(-)-cocaine binding mode. However, based on the simulated free energy profiles, a significant free energy barrier (∼5 kcal/mol) exists in the CocE-(+)-cocaine binding process whereas no obvious free energy barrier exists in the CocE-(-)-cocaine binding process, although the free energy barrier of ∼5 kcal/mol is not high enough to really slow down the CocE-(+)-cocaine binding process. In addition, the obtained free energy profiles also demonstrate that (+)-cocaine and (-)-cocaine have very close binding free energies with CocE, with a negligible difference (∼0.2 kcal/mol), which is qualitatively consistent with the nearly same experimental K M values of the CocE enzyme for (+)-cocaine and (-)-cocaine. The consistency between the computational results and available experimental data suggests that the mechanistic insights obtained from this study are reasonable. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  8. New results on the relation between tyre-road longitudinal stiffness and maximum available grip for motor car

    Science.gov (United States)

    Andrieux, A.; Vandanjon, P. O.; Lengelle, R.; Chabanon, C.

    2010-12-01

    Tyre-road estimation methods have been the objective of many research programmes throughout the world. Most of these methods aim at estimating the friction components such as tyre longitudinal slip rate κ and friction coefficient μ in the contact patch area. In order to estimate the maximum available friction coefficient μmax, these methods generally use a probabilistic relationship between the grip obtained for low tyre excitations (such as constant speed driving) and the grip obtained for high tyre excitations (such as emergency braking manoeuvre). Confirmation or invalidation of this relationship from experimental results is the purpose of this paper. Experiments have been carried out on a reference track including several test boards corresponding to a wide textural spectrum. The main advantage of these experiments lies in the use of a vehicle allowing us to accurately build point-by-point relationship between κ and μ. This relationship has been determined for different tyres and pavement textures. Finally, the curves obtained are analysed to check the validity of the relationship between the current friction coefficient used by the car during normal driving conditions and μmax.

  9. Installation of dynamic travel time signs and efforts to obtain and test a graphical route information panel (GRIP) sign in Austin.

    Science.gov (United States)

    2016-08-01

    Graphic Route Information Panel (GRIP) signs use a combination of text, colors, and representative maps of : the roadway system to convey real-time roadway congestion location and severity information. The intent of : this project was to facilitate t...

  10. Associations of work activities requiring pinch or hand grip or exposure to hand-arm vibration with finger and wrist osteoarthritis

    DEFF Research Database (Denmark)

    Hammer, Paula E C; Shiri, Rahman; Kryger, Ann I

    2014-01-01

    OBJECTIVE: We systematically reviewed the epidemiologic evidence linking finger and wrist osteoarthritis (OA) with work activities requiring pinch or hand grip or exposure to hand-arm vibration (HAV). METHODS: PubMed and Embase databases were searched up to June 2013. We selected studies assessing...

  11. The influence of respiratory acid-base changes on muscle performance and excitability of the sarcolemma during strenuous intermittent hand grip exercise.

    Science.gov (United States)

    Hilbert, M; Shushakov, V; Maassen, N

    2012-02-01

    Acidification has been reported to provide protective effects on force production in vitro. Thus, in this study, we tested if respiratory acid-base changes influence muscle function and excitability in vivo. Nine subjects performed strenuous, intermittent hand grip exercises (10 cycles of 15 s of work/45 s of rest) under respiratory acidosis by CO(2) rebreathing, alkalosis by hyperventilation, or control. The Pco(2), pH, K(+) concentration ([K(+)]), and Na(+) concentration were measured in venous and arterialized blood. Compound action potentials (M-wave) were elicited to examine the excitability of the sarcolemma. The surface electromyogram (EMG) was recorded to estimate the central drive to the muscle. The lowest venous pH during the exercise period was 7.24 ± 0.03 in controls, 7.31 ± 0.05 with alkalosis, and 7.17 ± 0.04 with acidosis (P alkalosis, and, after the second cycle, it was smaller with acidosis than with the control condition (P Respiratory alkalosis stabilized the M-wave area without influencing performance. Thus, we did not find a direct link between performance and alteration of excitability of the sarcolemma due to changes in pH in vivo.

  12. Transitions in the vortex wake behind the plunging profile

    Science.gov (United States)

    Kozłowski, Tomasz; Kudela, Henryk

    2014-12-01

    In this study we investigate numerically the vortex wake formation behind the profile performing simple harmonic motion known in the literature as plunging. This research was inspired by the flapping motion which is appropriate for birds, insects and fishes. We assume the two dimensional model of flow. Depending on the parameters such as plunging amplitude, frequency and the Reynolds number, we demonstrate many different types of vortex street behind the profile. It is well known that the type of vortex wake determines the hydrodynamic forces acting on the profile. Dependences of the plunging amplitude, the Strouhal number and various topology vortices are established by constructing the phase transition diagram. The areas in the diagram related to the drag, thrust, and lift force generation are captured. We notice also the areas where the vorticity field is disordered. The disordered vorticity field does not allow maintenance of the periodic forces on the profile. An increase in the Reynolds number leads to the transition of the vortex wake behind the profile. The transition is caused by the phenomenon of boundary layer eruption. Further increase of the Reynolds number causes the vortex street related to the generation of the lift force to vanish.

  13. Quantifying feedforward control: a linear scaling model for fingertip forces and object weight.

    Science.gov (United States)

    Lu, Ying; Bilaloglu, Seda; Aluru, Viswanath; Raghavan, Preeti

    2015-07-01

    The ability to predict the optimal fingertip forces according to object properties before the object is lifted is known as feedforward control, and it is thought to occur due to the formation of internal representations of the object's properties. The control of fingertip forces to objects of different weights has been studied extensively by using a custom-made grip device instrumented with force sensors. Feedforward control is measured by the rate of change of the vertical (load) force before the object is lifted. However, the precise relationship between the rate of change of load force and object weight and how it varies across healthy individuals in a population is not clearly understood. Using sets of 10 different weights, we have shown that there is a log-linear relationship between the fingertip load force rates and weight among neurologically intact individuals. We found that after one practice lift, as the weight increased, the peak load force rate (PLFR) increased by a fixed percentage, and this proportionality was common among the healthy subjects. However, at any given weight, the level of PLFR varied across individuals and was related to the efficiency of the muscles involved in lifting the object, in this case the wrist and finger extensor muscles. These results quantify feedforward control during grasp and lift among healthy individuals and provide new benchmarks to interpret data from neurologically impaired populations as well as a means to assess the effect of interventions on restoration of feedforward control and its relationship to muscular control. Copyright © 2015 the American Physiological Society.

  14. Sensing and Force-Feedback Exoskeleton (SAFE) Robotic Glove.

    Science.gov (United States)

    Ben-Tzvi, Pinhas; Ma, Zhou

    2015-11-01

    This paper presents the design, implementation and experimental validation of a novel robotic haptic exoskeleton device to measure the user's hand motion and assist hand motion while remaining portable and lightweight. The device consists of a five-finger mechanism actuated with miniature DC motors through antagonistically routed cables at each finger, which act as both active and passive force actuators. The SAFE Glove is a wireless and self-contained mechatronic system that mounts over the dorsum of a bare hand and provides haptic force feedback to each finger. The glove is adaptable to a wide variety of finger sizes without constraining the range of motion. This makes it possible to accurately and comfortably track the complex motion of the finger and thumb joints associated with common movements of hand functions, including grip and release patterns. The glove can be wirelessly linked to a computer for displaying and recording the hand status through 3D Graphical User Interface (GUI) in real-time. The experimental results demonstrate that the SAFE Glove is capable of reliably modeling hand kinematics, measuring finger motion and assisting hand grasping motion. Simulation and experimental results show the potential of the proposed system in rehabilitation therapy and virtual reality applications.

  15. Normative data for hand grip strength and key pinch strength, stratified by age and gender for a multiethnic Asian population.

    Science.gov (United States)

    Lam, Ngee Wei; Goh, Hui Ting; Kamaruzzaman, Shahrul Bahyah; Chin, Ai-Vyrn; Poi, Philip Jun Hua; Tan, Maw Pin

    2016-10-01

    Hand strength is a good indicator of physical fitness and frailty among the elderly. However, there are no published hand strength references for Malaysians aged > 65 years. This study aimed to establish normative data for hand grip strength (HGS) and key pinch strength (KPS) for Malaysians aged ≥ 60 years, and explore the relationship between hand strength and physical ability. Healthy participants aged ≥ 60 years with no neurological conditions were recruited from rural and urban locations in Malaysia. HGS and KPS were measured using hand grip and key pinch dynamometers. Basic demographic data, anthropometric measures, modified Barthel Index scores and results of the Functional Reach Test (FRT), Timed Up and Go (TUG) test and Jebsen-Taylor Hand Function Test (JTHFT) were recorded. 362 subjects aged 60-93 years were recruited. The men were significantly stronger than the women in both HGS and KPS (p Malaysia. Future studies are required to determine the modifiable factors for poor hand strength. Copyright: © Singapore Medical Association

  16. The influence of cooling forearm/hand and gender on estimation of handgrip strength.

    Science.gov (United States)

    Cheng, Chih-Chan; Shih, Yuh-Chuan; Tsai, Yue-Jin; Chi, Chia-Fen

    2014-01-01

    Handgrip strength is essential in manual operations and activities of daily life, but the influence of forearm/hand skin temperature on estimation of handgrip strength is not well documented. Therefore, the present study intended to investigate the effect of local cooling of the forearm/hand on estimation of handgrip strength at various target force levels (TFLs, in percentage of MVC) for both genders. A cold pressor test was used to lower and maintain the hand skin temperature at 14°C for comparison with the uncooled condition. A total of 10 male and 10 female participants were recruited. The results indicated that females had greater absolute estimation deviations. In addition, both genders had greater absolute deviations in the middle range of TFLs. Cooling caused an underestimation of grip strength. Furthermore, a power function is recommended for establishing the relationship between actual and estimated handgrip force. Statement of relevance: Manipulation with grip strength is essential in daily life and the workplace, so it is important to understand the influence of lowering the forearm/hand skin temperature on grip-strength estimation. Females and the middle range of TFL had greater deviations. Cooling the forearm/hand tended to cause underestimation, and a power function is recommended for establishing the relationship between actual and estimated handgrip force. Practitioner Summary: It is important to understand the effect of lowering the forearm/hand skin temperature on grip-strength estimation. A cold pressor was used to cool the hand. The cooling caused underestimation, and a power function is recommended for establishing the relationship between actual and estimated handgrip force. Manipulation with grip strength is essential in daily life and the workplace, so it is important to understand the influence of lowering the forearm/hand skin temperature on grip-strength estimation. Females and the middle range of TFL had greater deviations. Cooling the

  17. Analysis of the effects of hospitalization on fine hand functions compared to gross grip in patients with rheumatoid arthritis

    Directory of Open Access Journals (Sweden)

    Zeynep Tuna

    2015-09-01

    Full Text Available Objective: Hospitalization process causes a variety of physical problems. The decrease of hand use in daily life during hospitalization brings hand dysfunction to mind in inpatients. The aim of this study is to compare the hand functions of hospitalized patients with Rheumatoid Arthritis (RA to outpatients in detail. Methods: Grip and pinch strengths of both hospitalized patients in rheumatology service and outpatients on the routine control day were measured. In addition, 9-Hole Peg Test was performed and the disability level was determined by the Turkish version of Michigan Hand Outcomes Questionnaire (MHOQ. Results: While grip strength and MHOQ scores were similar (p>0.05 in both groups, all three pinch strengths (lateral, bipod, tripod and 9HPT scores were lower (p<0.05 in hospitalized patients. Conclusion: Consequently, besides disease activity, hospitalization process also impairs fine hand functions in rheumatological patients. Evaluation of fine hand functions and appropriate rehabilitative interventions may prevent further disability in hospitalized patients. J Clin Exp Invest 2015; 6 (3: 228-232

  18. The Effect of Hand Dimensions, Hand Shape and Some Anthropometric Characteristics on Handgrip Strength in Male Grip Athletes and Non-Athletes

    Science.gov (United States)

    Fallahi, Ali Asghar; Jadidian, Ali Akbar

    2011-01-01

    It has been suggested that athletes with longer fingers and larger hand surfaces enjoy stronger grip power. Therefore, some researchers have examined a number of factors and anthropometric variables that explain this issue. To our knowledge, the data is scarce. Thus, the aim of this study was to investigate the effect of hand dimensions, hand shape and some anthropometric characteristics on handgrip strength in male grip athletes and non-athletes. 80 subjects aged between 19 and 29 participated in this study in two groups including: national and collegian grip athletes (n=40), and non-athletes (n=40). Body height and mass were measured to calculate body mass index. The shape of the dominant hand was drawn on a piece of paper with a thin marker so that finger spans, finger lengths, and perimeters of the hand could be measured. The hand shape was estimated as the ratio of the hand width to hand length. Handgrip strength was measured in the dominant and non-dominant hand using a standard dynamometer. Descriptive statistics were used for each variable and independent t test was used to analyze the differences between the two groups. The Pearson correlation coefficient test was used to evaluate the correlation between studied variables. Also, to predict important variables in handgrip strength, the linear trend was assessed using a linear regression analysis. There was a significant difference between the two groups in absolute handgrip strength (p0.05) were significantly different between the groups (ptalent identification in handgrip-related sports and in clinical settings as well. PMID:23486361

  19. Left hand finger force in violin playing: tempo, loudness, and finger differences.

    Science.gov (United States)

    Kinoshita, Hiroshi; Obata, Satoshi

    2009-07-01

    A three-dimensional force transducer was installed in the neck of a violin under the A string at the D5 position in order to study the force with which the violinist clamps the string against the fingerboard under normal playing conditions. Violinists performed repetitive sequences of open A- and fingered D-tones using the ring finger at tempi of 1, 2, 4, 8, and 16 notes/s at mezzo-forte. At selected tempi, the effects of dynamic level and the use of different fingers were investigated as well. The force profiles were clearly dependent on tempo and dynamic level. At slow tempi, the force profiles were characterized by an initial pulse followed by a level force to the end of the finger contact period. At tempi higher than 2 Hz, only pulsed profiles were observed. The peak force exceeded 4.5 N at 1 and 2 Hz and decreased to 1.7 N at 16 Hz. All force and impulse values were lower at softer dynamic levels, and when using the ring or little finger compared to the index finger.

  20. Experimental Characterization of Radiation Forcing due to Atmospheric Aerosols

    Science.gov (United States)

    Sreenivas, K. R.; Singh, D. K.; Ponnulakshmi, V. K.; Subramanian, G.

    2011-11-01

    Micro-meteorological processes in the nocturnal atmospheric boundary layer (NBL) including the formation of radiation-fog and the development of inversion layers are controlled by heat transfer and the vertical temperature distribution close to the ground. In a recent study, it has been shown that the temperature profile close to the ground in stably-stratified, NBL is controlled by the radiative forcing due to suspended aerosols. Estimating aerosol forcing is also important in geo-engineering applications to evaluate the use of aerosols to mitigate greenhouse effects. Modeling capability in the above scenarios is limited by our knowledge of this forcing. Here, the design of an experimental setup is presented which can be used for evaluating the IR-radiation forcing on aerosols under either Rayleigh-Benard condition or under conditions corresponding to the NBL. We present results indicating the effect of surface emissivities of the top and bottom boundaries and the aerosol concentration on the temperature profiles. In order to understand the observed enhancement of the convection-threshold, we have determined the conduction-radiation time constant of an aerosol laden air layer. Our results help to explain observed temperature profiles in the NBL, the apparent stability of such profiles and indicate the need to account for the effect of aerosols in climatic/weather models.

  1. Effect of Isometric Hand Grip Exercises on Blood Flow and Placement of IV Catheters for Administration of Chemotherapy.

    Science.gov (United States)

    Ozkaraman, Ayse; Yesilbalkan, Öznur Usta

    2016-04-01

    Complications may occur in the subcutaneous or subdermal tissues during IV administration of chemotherapy related to blood flow and catheter placement. Daily isometric hand grip exercises were evaluated for their effect on blood flow in the vessels of the nondominant arm before placement of IV catheters and the success rate of IV catheter placement on the first attempt. The study focused on patients with non-Hodgkin lymphoma receiving the first and second cycles of chemotherapy. The intervention group performed daily isometric hand grip exercises before chemotherapy with peripheral catheter insertion. The control group performed routine activities only. Blood flow was measured by ultrasound in the brachial artery (BA) and brachial vein (BV) of the nondominant arm before the first (T1) and second (T2) cycles of chemotherapy. Blood flow slightly increased in the intervention group at T2 compared to T1. In the control group, blood flow decreased in the BA and did not change in the BV at T2 compared to T1. The success rate for first-attempt placement of a peripheral IV catheter was the same for the intervention and control groups.

  2. Transitions in the vortex wake behind the plunging profile

    Energy Technology Data Exchange (ETDEWEB)

    Kozłowski, Tomasz; Kudela, Henryk, E-mail: tomasz.kozlowski@pwr.wroc.pl, E-mail: henryk.kudela@pwr.wroc.pl [Department of Numerical Modelling of Flows, Wroclaw University of Technology, Wybrzeze Wyspianskiego 27, 50-370 Wroclaw (Poland)

    2014-12-01

    In this study we investigate numerically the vortex wake formation behind the profile performing simple harmonic motion known in the literature as plunging. This research was inspired by the flapping motion which is appropriate for birds, insects and fishes. We assume the two dimensional model of flow. Depending on the parameters such as plunging amplitude, frequency and the Reynolds number, we demonstrate many different types of vortex street behind the profile. It is well known that the type of vortex wake determines the hydrodynamic forces acting on the profile. Dependences of the plunging amplitude, the Strouhal number and various topology vortices are established by constructing the phase transition diagram. The areas in the diagram related to the drag, thrust, and lift force generation are captured. We notice also the areas where the vorticity field is disordered. The disordered vorticity field does not allow maintenance of the periodic forces on the profile. An increase in the Reynolds number leads to the transition of the vortex wake behind the profile. The transition is caused by the phenomenon of boundary layer eruption. Further increase of the Reynolds number causes the vortex street related to the generation of the lift force to vanish. (paper)

  3. Transitions in the vortex wake behind the plunging profile

    International Nuclear Information System (INIS)

    Kozłowski, Tomasz; Kudela, Henryk

    2014-01-01

    In this study we investigate numerically the vortex wake formation behind the profile performing simple harmonic motion known in the literature as plunging. This research was inspired by the flapping motion which is appropriate for birds, insects and fishes. We assume the two dimensional model of flow. Depending on the parameters such as plunging amplitude, frequency and the Reynolds number, we demonstrate many different types of vortex street behind the profile. It is well known that the type of vortex wake determines the hydrodynamic forces acting on the profile. Dependences of the plunging amplitude, the Strouhal number and various topology vortices are established by constructing the phase transition diagram. The areas in the diagram related to the drag, thrust, and lift force generation are captured. We notice also the areas where the vorticity field is disordered. The disordered vorticity field does not allow maintenance of the periodic forces on the profile. An increase in the Reynolds number leads to the transition of the vortex wake behind the profile. The transition is caused by the phenomenon of boundary layer eruption. Further increase of the Reynolds number causes the vortex street related to the generation of the lift force to vanish. (paper)

  4. Motor Unit Number Estimate and Isometric Hand Grip Strength in Military Veterans with or Without Muscular Complaints: Reference Values for Longitudinal Follow-up.

    Science.gov (United States)

    Li, Mian; Yao, Wenguo; Sundahl, Cynthia

    2018-03-26

    It remains unclear if Gulf War (GW) veterans have a higher risk of developing motor neuron disorder. We intended to establish baseline neurophysiological values, including thenar motor unit number estimate (MUNE) and isometric hand grip (IHG) strength, to compare future follow-ups of deployed GW veterans with or without muscular complaints. We evaluated 19 GW veterans with self-reported weakness, cramps, or excessive muscle fatigue (Ill-19) and compared them with 18 controls without such muscular complaints (C-18). We performed MUNE on hand thenar muscles using adapted multipoint stimulation method for Ill-19 and 15 controls (C-15). We measured IHG strength (maximum force, endurance, and fatigue level) on Ill-19 and C-18 with a hand dynamometer. We performed nerve conduction studies on all study participants to determine which subjects had mild carpal tunnel syndrome (CTS). We compared the MUNE and IHG strength measures between Ill group and controls and between those with CTS and those without CTS. We obtained thenar MUNE of Ill-19 (95% CI of mean: 143-215; mean age: 46 yr) and compared it with that of C-15 (95% CI of mean: 161-230; mean age: 45 yr), and 95% of CI of mean among IHG strength variables (maximum force: 324-381 Newton; endurance: 32-42 s; fatigue level: 24%-33%) compared with C-18 (maximum force: 349-408 Newton; endurance: 35-46 s; fatigue level: 21%-27%). There was no significant difference in either MUNE or IHG strength between Ill-19 group and controls. The MUNE and IHG maximum forces were significantly lower in those with CTS compared with those without CTS. As a surrogate of mild CTS, the median versus ulnar distal sensory latency on nerve conduction study was only weakly associated with MUNE, maximum force, and fatigue level, respectively. To our knowledge, no published study on MUNE reference values of military veteran population has been available. The quantifiable values of both thenar MUNE and IHG strength of military veterans serve as

  5. The Relationship of Digit Ratio (2D:4D) with Cerebral Lateralization and Grip Strength in Elite Swimmers

    Science.gov (United States)

    Acar, Hakan; Eler, Nebahat

    2018-01-01

    The index finger and the 4th finger ratio (2D:4D) is the indicator of the prenatal testosterone. The aim of this study is to investigate the relationship between 2D:4D, hand preference and hand grip strength in swimmers. A total of 80 elite swimmers, participated in the study. Height, body weight, body mass index (BMI), hand 2D:4D finger…

  6. Frequency specific activity in subthalamic nucleus correlates with hand bradykinesia in Parkinson's disease.

    Science.gov (United States)

    Tan, Huiling; Pogosyan, Alek; Anzak, Anam; Foltynie, Thomas; Limousin, Patricia; Zrinzo, Ludvic; Ashkan, Keyoumars; Bogdanovic, Marko; Green, Alexander L; Aziz, Tipu; Brown, Peter

    2013-02-01

    Local field potential recordings made from the basal ganglia of patients undergoing deep brain stimulation have suggested that frequency specific activity is involved in determining the rate of force development and the peak force at the outset of a movement. However, the extent to which the basal ganglia might be involved in motor performance later on in a sustained contraction is less clear. We therefore recorded from the subthalamic nucleus region (STNr) in patients with Parkinson's disease (PD) as they made maximal voluntary grips. Relative to age-matched controls they had more rapid force decrement when contraction was meant to be sustained and prolonged release reaction time and slower rate of force offset when they were supposed to release the grip. These impairments were independent from medication status. Increased STNr power over 5-12 Hz (in the theta/alpha band) independently predicted better performance-reduced force decrement, shortened release reaction time and faster rate of force offset. In contrast, lower mean levels and progressive reduction of STNr power over 55-375 Hz (high gamma/high frequency) over the period when contraction was meant to be sustained were both strongly associated with greater force decrement over time. Higher power over 13-23 Hz (low beta) was associated with more rapid force decrement during the period when grip should have been sustained, and with a paradoxical shortening of the release reaction time. These observations suggest that STNr activities at 5-12 Hz and 55-375 Hz are necessary for optimal grip performance and that deficiencies of such activities lead to motor impairments. In contrast, increased levels of 13-25 Hz activity both promote force decrement and shorten the release reaction time, consistent with a role in antagonising (and terminating) voluntary movement. Frequency specific oscillatory activities in the STNr impact on motor performance from the beginning to the end of a voluntary grip. Copyright © 2012

  7. An ab initio approach to free-energy reconstruction using logarithmic mean force dynamics

    International Nuclear Information System (INIS)

    Nakamura, Makoto; Obata, Masao; Morishita, Tetsuya; Oda, Tatsuki

    2014-01-01

    We present an ab initio approach for evaluating a free energy profile along a reaction coordinate by combining logarithmic mean force dynamics (LogMFD) and first-principles molecular dynamics. The mean force, which is the derivative of the free energy with respect to the reaction coordinate, is estimated using density functional theory (DFT) in the present approach, which is expected to provide an accurate free energy profile along the reaction coordinate. We apply this new method, first-principles LogMFD (FP-LogMFD), to a glycine dipeptide molecule and reconstruct one- and two-dimensional free energy profiles in the framework of DFT. The resultant free energy profile is compared with that obtained by the thermodynamic integration method and by the previous LogMFD calculation using an empirical force-field, showing that FP-LogMFD is a promising method to calculate free energy without empirical force-fields

  8. Ergonomics and comfort in lawn mower handle positioning: An evaluation of handle geometry.

    Science.gov (United States)

    Lowndes, Bethany R; Heald, Elizabeth A; Hallbeck, M Susan

    2015-11-01

    Hand operation accompanied with any combination of large forces, awkward positions and repetition may lead to upper limb injury or illness and may be exacerbated by vibration. Commercial lawn mowers expose operators to these factors during actuation of hand controls and therefore may be a health concern. A nontraditional lawn mower control system may decrease upper limb illnesses and injuries through more neutral hand and body positioning. This study compared maximum grip strength in twelve different orientations (3 grip spans and 4 positions) and evaluated self-described comfortable handle positions. The results displayed force differences between nontraditional (X) and both vertical (V) and pistol (P) positions (p < 0.0001) and among the different grip spans (p < 0.0001). Based on these results, recommended designs should incorporate a tilt between 45 and 70°, handle rotations between 48 and 78°, and reduced force requirements or decreased grip spans to improve user health and comfort. Copyright © 2015 Elsevier Ltd and The Ergonomics Society. All rights reserved.

  9. Changes in handgrip force and blood lactate as response to simulated climbing competition

    Directory of Open Access Journals (Sweden)

    J Gajewski

    2009-07-01

    Full Text Available The aim of the study was to estimate post-competition changes in handgrip strength and blood lactate in climbers and relationships of the studied variables with declared climbing ability of the tested athletes. Twenty one male climbers volunteered to take part in the experiment. Each subject took part in simulated lead climbing competition on the artificial wall – (difficulty 7a in French scale. The blood lactate concentration was measured pre-climbing and then 3 min and 30 min post-climbing. Grip force of both hands (dominant and non-dominant was measured twice – pre-climbing and 1 min post-climbing (semi-final. Maximum heart rate during climbing reached 181.4±7.7 beats per minute. Lactate concentration amounted to 6.35±1.50 mmol/l and 2.28±0.66 mmol/l 3 min and 30 min post-climbing, respectively. Handgrip force related to body mass (averaged for both hands decreased significantly from 7.39±1.30 N/kg pre-climbing to 6.57±1.05 N/kg 1 min post-climbing. Self reported climbing ability was correlated with lactate concentration and handgrip force, as well. It was demonstrated that athletes reporting higher climbing ability showed better lactate recovery.

  10. Effects of hand configuration on muscle force coordination, co-contraction and concomitant intermuscular coupling during maximal isometric flexion of the fingers.

    Science.gov (United States)

    Charissou, Camille; Amarantini, David; Baurès, Robin; Berton, Eric; Vigouroux, Laurent

    2017-11-01

    The mechanisms governing the control of musculoskeletal redundancy remain to be fully understood. The hand is highly redundant, and shows different functional role of extensors according to its configuration for a same functional task of finger flexion. Through intermuscular coherence analysis combined with hand musculoskeletal modelling during maximal isometric hand contractions, our aim was to better understand the neural mechanisms underlying the control of muscle force coordination and agonist-antagonist co-contraction. Thirteen participants performed maximal isometric flexions of the fingers in two configurations: power grip (Power) and finger-pressing on a surface (Press). Hand kinematics and force/moment measurements were used as inputs in a musculoskeletal model of the hand to determine muscular tensions and co-contraction. EMG-EMG coherence analysis was performed between wrist and finger flexors and extensor muscle pairs in alpha, beta and gamma frequency bands. Concomitantly with tailored muscle force coordination and increased co-contraction between Press and Power (mean difference: 48.08%; p force coordination during hand contractions. Our results highlight the functional importance of intermuscular coupling as a mechanism contributing to the control of muscle force synergies and agonist-antagonist co-contraction.

  11. Improving communication on hope in palliative care. A qualitative study of palliative care professionals' metaphors of hope: grip, source, tune, and vision.

    Science.gov (United States)

    Olsman, Erik; Duggleby, Wendy; Nekolaichuk, Cheryl; Willems, Dick; Gagnon, Judith; Kruizinga, Renske; Leget, Carlo

    2014-11-01

    Hope is important in palliative care. However, palliative care professionals' perspectives on hope are not well understood. Metaphors of hope are a way of better understanding these perspectives. To describe palliative care professionals' perspectives on hope by examining the hope metaphors they spontaneously used to describe their own hope and their perspectives on the hope of patients and their families. Semistructured interviews with palliative care professionals were recorded, transcribed, and analyzed using a narrative approach. Results were discussed until the researchers reached consensus and reinforced by other health-care professionals and by observing several palliative care settings. The 64 participants (mean (SD) age, 48.42 (9.27) years and 72% female) were physicians (41%), nurses (34%), chaplains (20%), or other professionals (5%), working in Canada (19%) or The Netherlands (81%). Participants described the hope of patients, their families, or themselves as a 1) grip, which implied safety; 2) source, which implied strength; 3) tune, which implied harmony; and 4) vision, which implied a positive perspective. Compared with Dutch participants, Canadian participants generally put more emphasis on spirituality and letting go of their own hope as a grip (safety). Compared with other included professionals, physicians used hope as a grip (safety) most often, whereas chaplains used hope as a tune (harmony) most often. Our findings help to increase the understanding of hope and contribute to improving communication skills in palliative care professionals. Copyright © 2014 American Academy of Hospice and Palliative Medicine. Published by Elsevier Inc. All rights reserved.

  12. In-situ piezoresponse force microscopy cantilever mode shape profiling

    International Nuclear Information System (INIS)

    Proksch, R.

    2015-01-01

    The frequency-dependent amplitude and phase in piezoresponse force microscopy (PFM) measurements are shown to be a consequence of the Euler-Bernoulli (EB) dynamics of atomic force microscope (AFM) cantilever beams used to make the measurements. Changes in the cantilever mode shape as a function of changes in the boundary conditions determine the sensitivity of cantilevers to forces between the tip and the sample. Conventional PFM and AFM measurements are made with the motion of the cantilever measured at one optical beam detector (OBD) spot location. A single OBD spot location provides a limited picture of the total cantilever motion, and in fact, experimentally observed cantilever amplitude and phase are shown to be strongly dependent on the OBD spot position for many measurements. In this work, the commonly observed frequency dependence of PFM response is explained through experimental measurements and analytic theoretical EB modeling of the PFM response as a function of both frequency and OBD spot location on a periodically poled lithium niobate sample. One notable conclusion is that a common choice of OBD spot location—at or near the tip of the cantilever—is particularly vulnerable to frequency dependent amplitude and phase variations stemming from dynamics of the cantilever sensor rather than from the piezoresponse of the sample

  13. Pain and fear avoidance partially mediate change in muscle strength during resistance exercise in women with fibromyalgia

    Directory of Open Access Journals (Sweden)

    Anette Larsson

    2017-10-01

    Methods: Sixty-seven women with fibromyalgia (age range 25–64 years were included. Tests of muscle strength and questionnaires related to pain, fear avoidance and physical activity were carried out. Multivariable stepwise regression was used to analyse explanatory factors for change and predictors for final values of knee-extension force, elbow-flexion force and hand-grip force. Results: Change in knee-extension force was explained by fear avoidance beliefs about physical activity at baseline, together with change in pain intensity, knee-extension force at baseline, age and body mass index (BMI (R2=0.40, p = 0.013. Change in elbow-flexion force was explained by pain intensity at baseline, together with baseline fear avoidance beliefs about physical activity, BMI and elbow-flexion force at baseline (R2 = 0.32, p = 0.043. Change in hand-grip force was explained by hand-grip force at baseline, change in pain intensity and baseline fear avoidance (R2 = 0.37, p = 0.009. Final muscle strength was predicted by the same variables as change, except pain. Conclusion: Pain and fear avoidance are important factors to consider in rehabilitation using resistance exercise for women with fibromyalgia.

  14. Solid state controller three axes controller

    Science.gov (United States)

    Bailey, C. L., Jr. (Inventor)

    1973-01-01

    The reported flight controller features a handle grip which is mounted on a longitudinally extending control element. The handle grip is pivotally mounted on the control element about a pitch axis which is perpendicular to the longitudinal axis through the control element. The pivotal mounting includes a resilient force mounting mechanism which centers the grip relative to the control element. Rotation of the handle grip produces a direct rotation of a transducer element in a transducer which provides an electrical indication of the rotative movement about three mutually perpendicular axes.

  15. Dextrous gripping in a hazardous environment

    International Nuclear Information System (INIS)

    Jongkind, W.

    1993-01-01

    Existing dextrous grippers are presented and compared, tasks to be performed in the hazardous environment are analyzed, and recommendations on gripper design and configuration are given. The outcome is a proposal for a dextrous gripper consisting of three antropomorphic fingers and an active palm. Sensor and actuator issues have been investigated and a selection of them has been made with respect to applicability in the hazardous environment. Theoretical contact issues were investigated and contacts have been modelled accordingly, followed by a kinematical analysis of the proposed gripper. Force and motion equations have been derived, and finger force distribution and computation has been analyzed. Grasp planning, the determination for a given task of a sequence of postures, to gurantee the safe and robust grasping of an object has been investigated. The determination of postures resulting in the designation of the number and categories of contact points before the fingers of the gripper contact the object is a matter of high-level grasping. The post-contact phase of the grasp, where set points for position and/or force have to be controlled, a matter of low-level grasp planning, has been investigated. The dissertation concluded with an investigation into the control of the gripper to achieve reliable grasps. The aim was to arrive at a controller that can comply with varying external forces and that can cope with imprecise known objects and imprecise task descriptions. Also the controlling of grasping forces as aimed at. The resulting gripper is radiation resistant. The methodology worked out in the dissertation is currently being applied to the design of a gripper able to operate in a hazardous nuclear environment. (orig./HP)

  16. Colloquium: Gripped by light: Optical binding

    Czech Academy of Sciences Publication Activity Database

    Dholakia, K.; Zemánek, Pavel

    2010-01-01

    Roč. 82, č. 2 (2010), s. 1767-1791 ISSN 0034-6861 R&D Projects: GA ČR GA202/09/0348; GA MŠk(CZ) LC06007 Institutional research plan: CEZ:AV0Z20650511 Keywords : discrete-dipole approximation * artificial kerr medium * focused laser-beam * near-field optics * radiation pressure * electromagnetic force * trapping force * nonlinear nanosuspensions * spherical nanoparticles * metal nanoparticles Subject RIV: BH - Optics, Masers, Lasers Impact factor: 51.695, year: 2010

  17. Beam profile measurements on RHIC

    International Nuclear Information System (INIS)

    Connolly, R.; Michnoff, R.; Moore, T.; Shea, T.; Tepikian, S.

    2000-01-01

    The Relativistic Heavy Ion Collider (RHIC) at Brookhaven National Lab was commissioned during the summer of 1999. Transverse beam profiles on RHIC are measured with ionization profile monitors (IPMs). An IPM measures beam profiles by collecting the electrons liberated by residual gas ionization by the beam. The detector is placed in the gap of a dipole magnet to force the electrons to travel in straight lines from the beamline center to the collector. One IPM was tested and it measured the profiles of a single gold bunch containing 10 8 ions on consecutive turns. We show an example of one of these profiles giving transverse emittance. Also several profiles are combined into a mountain-range plot which shows betatron oscillations at injection

  18. Kriging modeling and SPSA adjusting PID with KPWF compensator control of IPMC gripper for mm-sized objects

    Science.gov (United States)

    Chen, Yang; Hao, Lina; Yang, Hui; Gao, Jinhai

    2017-12-01

    Ionic polymer metal composite (IPMC) as a new smart material has been widely concerned in the micromanipulation field. In this paper, a novel two-finger gripper which contains an IPMC actuator and an ultrasensitive force sensor is proposed and fabricated. The IPMC as one finger of the gripper for mm-sized objects can achieve gripping and releasing motion, and the other finger works not only as a support finger but also as a force sensor. Because of the feedback signal of the force sensor, this integrated actuating and sensing gripper can complete gripping miniature objects in millimeter scale. The Kriging model is used to describe nonlinear characteristics of the IPMC for the first time, and then the control scheme called simultaneous perturbation stochastic approximation adjusting a proportion integration differentiation parameter controller with a Kriging predictor wavelet filter compensator is applied to track the gripping force of the gripper. The high precision force tracking in the foam ball manipulation process is obtained on a semi-physical experimental platform, which demonstrates that this gripper for mm-sized objects can work well in manipulation applications.

  19. Stable isotope ratio mass spectrometry and physical comparison for the forensic examination of grip-seal plastic bags.

    Science.gov (United States)

    Taylor, Erica; Carter, James F; Hill, Jenny C; Morton, Carolyn; Daeid, Niamh Nic; Sleeman, Richard

    2008-05-20

    Plastic bags are frequently used to package drugs, explosives and other contraband. There exists, therefore, a requirement in forensic casework to compare bags found at different locations. This is currently achieved almost exclusively by the use of physical comparisons such as birefringence patterns. This paper discusses some of the advantages and shortcomings of this approach, and presents stable isotope ratio mass spectrometry (IRMS) as a supplementary tool for effecting comparisons of this nature. Carbon and hydrogen isotopic data are presented for sixteen grip-seal plastic bags from a wide range of sources, in order to demonstrate the range of values which is likely to be encountered. Both isotopic and physical comparison (specifically birefringence) techniques are then applied to the analysis of rolls of bags from different manufacturing lots from a leading manufacturer. Both approaches are able to associate bags from a common production batch. IRMS can be applied to small fragments which are not amenable to physical comparisons, and is able to discriminate bags which could be confused using birefringence patterns alone. Similarly, in certain cases birefringence patterns discriminate bags with similar isotopic compositions. The two approaches are therefore complementary. When more than one isotopically distinct region exists within a bag (e.g. the grip-seal is distinct from the body) the ability to discriminate and associate bags is greatly increased.

  20. Closed-loop control of grasping with a myoelectric hand prosthesis: which are the relevant feedback variables for force control?

    Science.gov (United States)

    Ninu, Andrei; Dosen, Strahinja; Muceli, Silvia; Rattay, Frank; Dietl, Hans; Farina, Dario

    2014-09-01

    In closed-loop control of grasping by hand prostheses, the feedback information sent to the user is usually the actual controlled variable, i.e., the grasp force. Although this choice is intuitive and logical, the force production is only the last step in the process of grasping. Therefore, this study evaluated the performance in controlling grasp strength using a hand prosthesis operated through a complete grasping sequence while varying the feedback variables (e.g., closing velocity, grasping force), which were provided to the user visually or through vibrotactile stimulation. The experiments were conducted on 13 volunteers who controlled the Otto Bock Sensor Hand Speed prosthesis. Results showed that vibrotactile patterns were able to replace the visual feedback. Interestingly, the experiments demonstrated that direct force feedback was not essential for the control of grasping force. The subjects were indeed able to control the grip strength, predictively, by estimating the grasping force from the prosthesis velocity of closing. Therefore, grasping without explicit force feedback is not completely blind, contrary to what is usually assumed. In our study we analyzed grasping with a specific prosthetic device, but the outcomes are also applicable for other devices, with one or more degrees-of-freedom. The necessary condition is that the electromyography (EMG) signal directly and proportionally controls the velocity/grasp force of the hand, which is a common approach among EMG controlled prosthetic devices. The results provide important indications on the design of closed-loop EMG controlled prosthetic systems.

  1. The association between physical activity and risk of mortality is modulated by grip strength and cardiorespiratory fitness: evidence from 498 135 UK-Biobank participants

    Science.gov (United States)

    Celis-Morales, Carlos A.; Lyall, Donald M.; Anderson, Jana; Iliodromiti, Stamatina; Fan, Yu; Ntuk, Uduakobong E.; Mackay, Daniel F.; Pell, Jill P.; Sattar, Naveed; Gill, Jason M.R.

    2017-01-01

    Aims It is unclear whether the potential benefits of physical activity differ according to level of cardiorespiratory fitness (CRF) or strength. The aim of this study was to determine whether the association between physical activity and mortality is moderated by CRF and grip strength sufficiently to inform health promotion strategies. Methods and results 498 135 participants (54.7% women) from the UK Biobank were included (CRF data available in 67 702 participants). Exposure variables were grip strength, CRF, and physical activity. All-cause mortality and cardiovascular disease (CVD) events were the outcomes. 8591 died over median 4.9 years [IQR 4.3–5.5] follow-up. There was a significant interaction between total physical activity and grip strength (P interaction with CRF did not reach statistical significance but the pattern was similar. The association between physical activity and mortality was larger among those in the lowest tertile of CRF (HR:1.13 [1.02–1.26]) than those in the highest (HR:1.03 [0.91–1.16]). The pattern for CVD events was similar. Conclusions These data provide novel evidence that strength, and possibly CRF, moderate the association between physical activity and mortality. The association between physical activity and mortality is strongest in those with the lowest strength (which is easily measured), and the lowest CRF, suggesting that these sub-groups could benefit most from interventions to increase physical activity. PMID:28158566

  2. Effect of cervical vs. thoracic spinal manipulation on peripheral neural features and grip strength in subjects with chronic mechanical neck pain: a randomized controlled trial.

    Science.gov (United States)

    Bautista-Aguirre, Francisco; Oliva-Pascual-Vaca, Ángel; Heredia-Rizo, Alberto M; Boscá-Gandía, Juan J; Ricard, François; Rodriguez-Blanco, Cleofás

    2017-06-01

    Cervical and thoracic spinal manipulative therapy has shown positive impact for relief of pain and improve function in non-specific mechanical neck pain. Several attempts have been made to compare their effectiveness although previous studies lacked a control group, assessed acute neck pain or combined thrust and non-thrust techniques. To compare the immediate effects of cervical and thoracic spinal thrust manipulations on mechanosensitivity of upper limb nerve trunks and grip strength in patients with chronic non-specific mechanical neck pain. Randomized, single-blinded, controlled clinical trial. Private physiotherapy clinical consultancy. Eighty-eight subjects (32.09±6.05 years; 72.7% females) suffering neck pain (grades I or II) of at least 12 weeks of duration. Participants were distributed into three groups: 1) cervical group (N.=28); 2) thoracic group (N.=30); and 3) control group (N.=30). One treatment session consisting of applying a high-velocity low-amplitude spinal thrust technique over the lower cervical spine (C7) or the upper thoracic spine (T3) was performed, while the control group received a sham-manual contact. Measurements were taken at baseline and after intervention of the pressure pain threshold over the median, ulnar and radial nerves. Secondary measures included assessing free-pain grip strength with a hydraulic dynamometer. No statistically significant differences were observed when comparing between-groups in any of the outcome measures (P>0.05). Those who received thrust techniques, regardless of the manipulated area, reported an immediate increase in mechanosensitivity over the radial (both sides) and left ulnar nerve trunks (Ppain perception over the radial nerve also improved (P≤0.025). Low-cervical and upper-thoracic thrust manipulation is no more effective than placebo to induce immediate changes on mechanosensitivity of upper limb nerve trunks and grip strength in patients with chronic non-specific mechanical neck pain. A single

  3. Coming to Grips with Breast Cancer: The Spouse’s Experience with His Wife’s First Six Months

    OpenAIRE

    Zahlis, Ellen H.; Lewis, Frances M.

    2010-01-01

    This study examines the experiences of 48 spouses of wives newly diagnosed with local or regional breast cancer. Their reported experiences were organized into the core construct of Coming to Grips reflected by four domains: (1) Feeling nailed by the breast cancer; (2) Changing us; (3) Taking care of me; and (4) Making things work. Prior studies have underestimated the extent to which the assumptive world and day-to-day lives of spouses are shattered by the diagnosis of breast cancer and the ...

  4. Associations of Walking Speed, Grip Strength, and Standing Balance With Total and Cause-Specific Mortality in a General Population of Japanese Elders.

    Science.gov (United States)

    Nofuji, Yu; Shinkai, Shoji; Taniguchi, Yu; Amano, Hidenori; Nishi, Mariko; Murayama, Hiroshi; Fujiwara, Yoshinori; Suzuki, Takao

    2016-02-01

    Walking speed, grip strength, and standing balance are key components of physical performance in older people. The present study aimed to evaluate (1) associations of these physical performance measures with cause-specific mortality, (2) independent associations of individual physical performance measures with mortality, and (3) the added value of combined use of the 3 physical performance measures in predicting all-cause and cause-specific mortality. Prospective cohort study with a follow-up of 10.5 years. Tokyo Metropolitan Institute of Gerontology Longitudinal Interdisciplinary Study on Aging (TMIG-LISA), Japan. A total of 1085 initially nondisabled older Japanese aged 65 to 89 years. Usual walking speed, grip strength, and standing balance were measured at baseline survey. During follow-up, 324 deaths occurred (122 of cardiovascular disease, 75 of cancer, 115 of other causes, and 12 of unknown causes). All 3 physical performance measures were significantly associated with all-cause, cardiovascular, and other-cause mortality, but not with cancer mortality, independent of potential confounders. When all 3 physical performance measures were simultaneously entered into the model, each was significantly independently associated with all-cause and cardiovascular mortality. The C statistics for all-cause and cardiovascular mortality were significantly increased by adding grip strength and standing balance to walking speed (P balance predicted all-cause, cardiovascular, and other-cause mortality, but not cancer mortality, independent of covariates. Moreover, these 3 components of physical performance were independently associated with all-cause and cardiovascular mortality and their combined use increased prognostic power. Copyright © 2016 AMDA – The Society for Post-Acute and Long-Term Care Medicine. Published by Elsevier Inc. All rights reserved.

  5. Essentiality of Temperature Management while Modeling and Analyzing Tires Contact Forces

    OpenAIRE

    Corollaro, Alfredo

    2014-01-01

    The influence of temperature on tire performance is subject of matter in Research for many years. It is well known that the temperature affects the grip level of the tire and the cornering stiffness at the same time. Anyway, while the influence of temperature on grip level has been deeply investigated in different activities, the influence on cornering stiffness seems to be not sufficiently discussed yet. As shown in this work, the reason could be that the cornering stiffness is not influ...

  6. Attractive forces study in macromolecules and critical systems; Etude des forces attractives dans les macromolecules et les systemes critiques

    Energy Technology Data Exchange (ETDEWEB)

    Penninckx-Sans, A.

    1995-07-10

    The attractive forces effect is particularly interesting at the proximity of a critical point. In a liquid system, there are two kinds of attractive forces in presence : the forces bound to the solution volume and those generated by the presence of the solution surface or by a solution interface. In the first case, the attractive forces are the more important as the system is in a critical field. For this study, the selected example is a polymer solution in a two solvents mixture. A formulation in terms of way integrals as part of statistical physics has lead us to find again some known results on the polymer chain conformation in the presence of two solvents (collapse of the polymer on itself) far from the critical point and to extend these results to the critical field. In the case of attractive forces created by the surface in some critical systems (polymer of infinite size in solution and binary mixture near the de mixture point), the adsorption profile created by the attraction of one specie by the surface, follows a scale law. The optical methods usually used for the study of these systems do not give characteristic sign of concentration profile in power law. In the case where the interaction potential between radiation and matter is attractive, the reflectivity gives a separate mark of the existence of the scale law in the form of a resonance. After some theoretical forecasts, the author has used this method on the binary mixture methanol-cyclohexane in order to reveal experimentally a reflectivity pseudo-discontinuity and then the existence of the power law in the critical adsorption profile. (O.L.). 69 refs., 60 tabs.

  7. Ücretsiz mevsimsel grip aşılarını yaptıran kişilerin, ücretsiz pandemik grip aşısı karşısındaki tutum ve davranışları

    Directory of Open Access Journals (Sweden)

    Muzaffer Eskiocak

    2011-09-01

    Full Text Available Amaç: Bu çalışma, mevsimsel grip aşısına (MGA ücretsiz erişen insanların tutum ve davranışlarını, yine ücretsiz, ama çeşitli tartışmalara konu olan pandemik grip aşısı (PGA karşısındaki tutum ve davranışlarıyla karşılaştırmak amacıyla yapılmıştır. Yöntem: Araştırma tanımlayıcı tipte bir araştırmadır ve Kırklareli-Evrensekiz Sağlık Ocağı bölgesinde, Şubat,2009–Şubat,2010 tarihleri arasında yürütülmüştür. Çalışma anketi yüz-yüze görüşme yöntemiyle doldurulmuştur. Bulgular: Katılımcıların %99,2’si (n=125 kamu kurumlarının ücretsiz MGA sağlamasını destekliyordu ve tamamı (N=126 gelecek yıl da ücretsiz MGA temin edilmesini istiyordu. 2010 yılında yapılan ikinci ankette ücretsiz sağlanan PGA olanların oranının ise %4 (n=5 olduğu tespit edildi. Sonuç: Bağışıklama hizmetlerinden yararlanmada ekonomik faktörlerin çok önemli olduğu, ancak toplumun güven duygusunun zedelenmesinin, ücretsiz sağlansa da aşılamayı ciddi düzeyde engellediği saptanmıştır.Anahtar Kelimeler: Mevsimsel grip aşısı, pandemik grip aşısı Attitudes and behaviors related to free pandemic influenza vaccination of who gets vaccinated with free seasonal influenza vaccine  Objective: This study aims to compare attitudes and behaviors of the people who receive free Seasonal Influenza Vaccine (SIV with their attitudes and behaviors against Pandemic Influenza Vaccine (PIV which is also free, but controversial. Method: This study is a descriptive survey which was carried out within the service area of Evrensekiz Primary Healthcare Center (PHC in Kırklareli province and it was conducted between February 2009 and February 2010. The questionnaire has been applied by face to face interviews. Results: 99,2%of participants (n=125 supported providing free influenza vaccine by governmental organizations and all of them (N=126 wanted to get free influenza vaccine the next year

  8. Finger Forces in Clarinet Playing

    Directory of Open Access Journals (Sweden)

    Alex Hofmann

    2016-08-01

    Full Text Available Clarinettists close and open multiple tone holes to alter the pitch of the tones. Their fingering technique must be fast, precise, and coordinated with the tongue articulation. In this empirical study, finger force profiles and tongue techniques of clarinet students (N = 17 and professional clarinettists (N = 6 were investigated under controlled performance conditions. First, in an expressive-performance task, eight selected excerpts from the first Weber Concerto were performed. These excerpts were chosen to fit in a 2 x 2 x 2 design (register: low--high; tempo: slow--fast, dynamics: soft--loud. There was an additional condition controlled by the experimenter, which determined the expression levels (low--high of the performers. Second, a technical-exercise task, an isochronous 23-tone melody was designed that required different effectors to produce the sequence (finger-only, tongue-only, combined tongue-finger actions. The melody was performed in three tempo conditions (slow, medium, fast in a synchronization-continuation paradigm. Participants played on a sensor-equipped Viennese clarinet, which tracked finger forces and reed oscillations simultaneously. From the data, average finger force (Fmean and peak force (Fmax were calculated. The overall finger forces were low (Fmean = 1.17 N, Fmax = 3.05 N compared to those on other musical instruments (e.g. guitar. Participants applied the largest finger forces during the high expression level performance conditions (Fmean = 1.21 N.For the technical exercise task, timing and articulation information were extracted from the reed signal. Here, the timing precision of the fingers deteriorated the timing precision of the tongue for combined tongue-finger actions, especially for faster tempi. Although individual finger force profiles were overlapping, the group of professional players applied less finger force overall (Fmean = 0.54 N. Such sensor instruments provide useful insights into player

  9. Development of an optimum end-effector with a nano-scale uneven surface for non-adhesion cell manipulation using a micro-manipulator

    International Nuclear Information System (INIS)

    Horade, M; Kojima, M; Kamiyama, K; Kurata, T; Mae, Y; Arai, T

    2015-01-01

    In order to realize effective micro-manipulation using a micro-manipulator system, an optimum end-effector is proposed. Cell-manipulation experiments using mouse fibroblast cells are conducted, and the usability of the proposed end-effector is confirmed. A key advantage of the micro-manipulator is high-accuracy, high-speed 3D micro- and nano-scale positioning. Micro-manipulation has often been used in research involving biological cells. However, there are two important concerns with the micro-manipulator system: gripping efficiency and the release of gripped objects. When it is not possible to grip a micro-object, such as a cell, near its center, the object may be dropped during manipulation. Since the acquisition of exact position information for a micro-object in the vertical direction is difficult using a microscope, the gripping efficiency of the end-effector should be improved. Therefore, technical skill or operational support is required. Since, on the micro-scale, surface forces such as the adsorption force are greater than body forces, such as the gravitational force, the adhesion force between the end-effector and the object is strong. Therefore, manipulation techniques without adhesion are required for placed an object at an arbitrary position. In the present study, we consider direct physical contact between the end-effector and objects. First, the design and materials of the end-effector for micro-scale manipulation were optimized, and an end-effector with an optimum shape to increase the grip force was fabricated. Second, the surface of the end-effector tip was made uneven, and the adhesion force from increasing on the micro-scale was prevented. When an end-effector with an uneven surface was used, release without adhesion was successful 85.0% of the time. On the other hand, when an end-effector without an uneven surface was used, release without adhesion was successful 6.25% of the time. Therefore, the superiority of a structure with an uneven

  10. Medial Elbow Joint Space Increases With Valgus Stress and Decreases When Cued to Perform A Maximal Grip Contraction.

    Science.gov (United States)

    Pexa, Brett S; Ryan, Eric D; Myers, Joseph B

    2018-04-01

    Previous research indicates that the amount of valgus torque placed on the elbow joint during overhead throwing is higher than the medial ulnar collateral ligament (UCL) can tolerate. Wrist and finger flexor muscle activity is hypothesized to make up for this difference, and in vitro studies that simulated activity of upper extremity musculature, specifically the flexor digitorum superficialis and flexor carpi ulnaris, support this hypothesis. To assess the medial elbow joint space at rest, under valgus stress, and under valgus stress with finger and forearm flexor contraction by use of ultrasonography in vivo. Controlled laboratory study. Participants were 22 healthy males with no history of elbow dislocation or UCL injury (age, 21.25 ± 1.58 years; height, 1.80 ± 0.08 m; weight, 79.43 ± 18.50 kg). Medial elbow joint space was measured by use of ultrasonography during 3 separate conditions: at rest (unloaded), under valgus load (loaded), and with a maximal grip contraction under a valgus load (loaded-contracted) in both limbs. Participants lay supine with their arm abducted 90° and elbow flexed 30° with the forearm in full supination. A handgrip dynamometer was placed in the participants' hand to grip against during the contracted condition. Images were reduced in ImageJ to assess medial elbow joint space. A 2-way (condition × limb) repeated-measures analysis of variance and Cohen's d effect sizes were used to assess changes in medial elbow joint space. Post hoc testing was performed with a Bonferroni adjustment to assess changes within limb and condition. The medial elbow joint space was significantly larger in the loaded condition (4.91 ± 1.16 mm) compared with the unloaded condition (4.26 ± 1.23 mm, P space increases under a valgus load and then decreases when a maximal grip contraction is performed. This indicates that wrist and finger flexor muscle contraction may assist in limiting medial elbow joint space, a result similar to findings of previous

  11. Vertical microphysical profiles of convective clouds as a tool for obtaining aerosol cloud-mediated climate forcings

    Energy Technology Data Exchange (ETDEWEB)

    Rosenfeld, Daniel [Hebrew Univ. of Jerusalem (Israel)

    2015-12-23

    Quantifying the aerosol/cloud-mediated radiative effect at a global scale requires simultaneous satellite retrievals of cloud condensation nuclei (CCN) concentrations and cloud base updraft velocities (Wb). Hitherto, the inability to do so has been a major cause of high uncertainty regarding anthropogenic aerosol/cloud-mediated radiative forcing. This can be addressed by the emerging capability of estimating CCN and Wb of boundary layer convective clouds from an operational polar orbiting weather satellite. Our methodology uses such clouds as an effective analog for CCN chambers. The cloud base supersaturation (S) is determined by Wb and the satellite-retrieved cloud base drop concentrations (Ndb), which is the same as CCN(S). Developing and validating this methodology was possible thanks to the ASR/ARM measurements of CCN and vertical updraft profiles. Validation against ground-based CCN instruments at the ARM sites in Oklahoma, Manaus, and onboard a ship in the northeast Pacific showed a retrieval accuracy of ±25% to ±30% for individual satellite overpasses. The methodology is presently limited to boundary layer not raining convective clouds of at least 1 km depth that are not obscured by upper layer clouds, including semitransparent cirrus. The limitation for small solar backscattering angles of <25º restricts the satellite coverage to ~25% of the world area in a single day. This methodology will likely allow overcoming the challenge of quantifying the aerosol indirect effect and facilitate a substantial reduction of the uncertainty in anthropogenic climate forcing.

  12. Isometric hand grip strength measured by the Nintendo Wii Balance Board - a reliable new method.

    Science.gov (United States)

    Blomkvist, A W; Andersen, S; de Bruin, E D; Jorgensen, M G

    2016-02-03

    Low hand grip strength is a strong predictor for both long-term and short-term disability and mortality. The Nintendo Wii Balance Board (WBB) is an inexpensive, portable, wide-spread instrument with the potential for multiple purposes in assessing clinically relevant measures including muscle strength. The purpose of the study was to explore intrarater reliability and concurrent validity of the WBB by comparing it to the Jamar hand dynamometer. Intra-rater test-retest cohort design with randomized validity testing on the first session. Using custom WBB software, thirty old adults (69.0 ± 4.2 years of age) were studied for reproducibility and concurrent validity compared to the Jamar hand dynamometer. Reproducibility was tested for dominant and non-dominant hands during the same time-of-day, one week apart. Intraclass correlation coefficient (ICC) and standard error of measurement (SEM) and limits of agreement (LOA) were calculated to describe relative and absolute reproducibility respectively. To describe concurrent validity, Pearson's product-moment correlation and ICC was calculated. Reproducibility was high with ICC values of >0.948 across all measures. Both SEM and LOA were low (0.2-0.5 kg and 2.7-4.2 kg, respectively) in both the dominant and non-dominant hand. For validity, Pearson correlations were high (0.80-0.88) and ICC values were fair to good (0.763-0.803). Reproducibility for WBB was high for relative measures and acceptable for absolute measures. In addition, concurrent validity between the Jamar hand dynamometer and the WBB was acceptable. Thus, the WBB may be a valid instrument to assess hand grip strength in older adults.

  13. Pneumatic-type surgical robot end-effector for laparoscopic surgical-operation-by-wire.

    Science.gov (United States)

    Lee, Chiwon; Park, Woo Jung; Kim, Myungjoon; Noh, Seungwoo; Yoon, Chiyul; Lee, Choonghee; Kim, Youdan; Kim, Hyeon Hoe; Kim, Hee Chan; Kim, Sungwan

    2014-09-05

    Although minimally invasive surgery (MIS) affords several advantages compared to conventional open surgery, robotic MIS systems still have many limitations. One of the limitations is the non-uniform gripping force due to mechanical strings of the existing systems. To overcome this limitation, a surgical instrument with a pneumatic gripping system consisting of a compressor, catheter balloon, micro motor, and other parts is developed. This study aims to implement a surgical instrument with a pneumatic gripping system and pitching/yawing joints using micro motors and without mechanical strings based on the surgical-operation-by-wire (SOBW) concept. A 6-axis external arm for increasing degrees of freedom (DOFs) is integrated with the surgical instrument using LabVIEW® for laparoscopic procedures. The gripping force is measured over a wide range of pressures and compared with the simulated ideal step function. Furthermore, a kinematic analysis is conducted. To validate and evaluate the system's clinical applicability, a simple peg task experiment and workspace identification experiment are performed with five novice volunteers using the fundamentals of laparoscopic surgery (FLS) board kit. The master interface of the proposed system employs the hands-on-throttle-and-stick (HOTAS) controller used in aerospace engineering. To develop an improved HOTAS (iHOTAS) controller, 6-axis force/torque sensor was integrated in the special housing. The mean gripping force (after 1,000 repetitions) at a pressure of 0.3 MPa was measured to be 5.8 N. The reaction time was found to be 0.4 s, which is almost real-time. All novice volunteers could complete the simple peg task within a mean time of 176 s, and none of them exceeded the 300 s cut-off time. The system's workspace was calculated to be 11,157.0 cm3. The proposed pneumatic gripping system provides a force consistent with that of other robotic MIS systems. It provides near real-time control. It is more durable than the

  14. Applications of pressure-sensitive dielectric elastomer sensors

    Science.gov (United States)

    Böse, Holger; Ocak, Deniz; Ehrlich, Johannes

    2016-04-01

    Dielectric elastomer sensors for the measurement of compression loads with high sensitivity are described. The basic design of the sensors exhibits two profiled surfaces between which an elastomer film is confined. All components of the sensor were prepared with silicone whose stiffness can be varied in a wide range. Depending on details of the sensor design, various effects contribute to the enhancement of the capacitance. The intermediate elastomer film is stretched upon compression and electrode layers on the elastomer profiles and in the elastomer film approach each other. Different designs of the pressure sensor give rise to very different sensor characteristics in terms of the dependence of electric capacitance on compression force. Due to their inherent flexibility, the pressure sensors can be used on compliant substrates such as seats or beds or on the human body. This gives rise to numerous possible applications. The contribution describes also some examples of possible sensor applications. A glove was equipped with various sensors positioned at the finger tips. When grabbing an object with the glove, the sensors can detect the gripping forces of the individual fingers with high sensitivity. In a demonstrator of the glove equipped with seven sensors, the capacitances representing the gripping forces are recorded on a display. In another application example, a lower limb prosthesis was equipped with a pressure sensor to detect the load on the remaining part of the leg and the load is displayed in terms of the measured capacitance. The benefit of such sensors is to detect an eventual overload in order to prevent possible pressure sores. A third example introduces a seat load sensor system based on four extended pressure sensor mats. The sensor system detects the load distribution of a person on the seat. The examples emphasize the high performance of the new pressure sensor technology.

  15. Approximate Stokes Drift Profiles in Deep Water

    Science.gov (United States)

    Breivik, Øyvind; Janssen, Peter A. E. M.; Bidlot, Jean-Raymond

    2014-09-01

    A deep-water approximation to the Stokes drift velocity profile is explored as an alternative to the monochromatic profile. The alternative profile investigated relies on the same two quantities required for the monochromatic profile, viz the Stokes transport and the surface Stokes drift velocity. Comparisons with parametric spectra and profiles under wave spectra from the ERA-Interim reanalysis and buoy observations reveal much better agreement than the monochromatic profile even for complex sea states. That the profile gives a closer match and a more correct shear has implications for ocean circulation models since the Coriolis-Stokes force depends on the magnitude and direction of the Stokes drift profile and Langmuir turbulence parameterizations depend sensitively on the shear of the profile. The alternative profile comes at no added numerical cost compared to the monochromatic profile.

  16. Phytochemical screening and analgesic profile of the lyophilized aqueous extract obtained from Chrysobalanus icaco leaves in experimental protocols.

    Science.gov (United States)

    Araújo-Filho, Heitor G; Dias, Jessica Deise Santos; Quintans-Júnior, Lucindo J; Santos, Márcio R V; White, Pollyanna A S; Barreto, Rosana S S; Barreto, André S; Estevam, Charles S; Araujo, Silvan S; Almeida, Jackson R G S; Menezes, Irwin R A; Coutinho, Henrique D M; Quintans, Jullyana S S

    2016-12-01

    Chrysobalanus icaco L. (Chrysobalanaceae) has been used for the treatment of abdominal pain and cramps. Assess the chemical and pharmacological profile of the lyophilized aqueous extract from C. icaco leaves (AEC). Chromatographic methods were used to assess compounds from AEC. Mice were treated with vehicle (control group) or AEC (100, 200 or 400 mg/kg, p.o.) (group with 7-8 mice) and the analgesic profile was assessed employing the acetic acid-induced writhing, formalin, hot plate tests and hyperalgesia induced by carrageenan (CG) or tumour necrosis factor-alpha. The animal motor performance was assessed using rota-rod and grip strength tests. The chromatographic profile of AEC demonstrated the presence of terpenoid compounds. The acute pretreatment with AEC, at all doses, produced a significant (p acetic acid-induced writhing test. In the formalin test, AEC were effective in the second phase (p analgesic and anti-inflammatory properties. So, these results corroborate the experiments using the AEC in inflammatory pain protocols. Our results suggest that AEC act against inflammatory pain.

  17. Pain and fear avoidance partially mediate change in muscle strength during resistance exercise in women with fibromyalgia.

    Science.gov (United States)

    Larsson, Anette; Palstam, Annie; Löfgren, Monika; Ernberg, Malin; Bjersing, Jan; Bileviciute-Ljungar, Indre; Gerdle, Björn; Kosek, Eva; Mannerkorpi, Kaisa

    2017-11-21

    Resistance exercise results in health benefits in fibromyalgia. The aim of this study was to determine the factors that mediate change in muscle strength in women with fibromyalgia as a result of resistance exercise. Sixty-seven women with fibromyalgia (age range 25-64 years) were included. Tests of muscle strength and questionnaires related to pain, fear avoidance and physical activity were carried out. Multivariable stepwise regression was used to analyse explanatory factors for change and predictors for final values of knee-extension force, elbow-flexion force and hand-grip force. Change in knee-extension force was explained by fear avoidance beliefs about physical activity at baseline, together with change in pain intensity, knee-extension force at baseline, age and body mass index (BMI) (R2=0.40, p = 0.013). Change in elbow-flexion force was explained by pain intensity at baseline, together with baseline fear avoidance beliefs about physical activity, BMI and elbow-flexion force at baseline (R2 = 0.32, p = 0.043). Change in hand-grip force was explained by hand-grip force at baseline, change in pain intensity and baseline fear avoidance (R2 = 0.37, p = 0.009). Final muscle strength was predicted by the same variables as change, except pain. Pain and fear avoidance are important factors to consider in rehabilitation using resistance exercise for women with fibromyalgia.

  18. Management of displaced inferior patellar pole fractures with modified tension band technique combined with cable cerclage using Cable Grip System.

    Science.gov (United States)

    Yang, Xu; Wu, Qinfen; Lai, Chin-Hui; Wang, Xin

    2017-10-01

    We present a modified tension band technique combined with cable cerclage using Cable Grip System for the treatment of displaced inferior patellar pole fractures and report the knee functional outcome. The patients who had had operative treatment of a displaced inferior patellar pole fracture (AO/OTA 34-A1) between December 2013 and December 2015 were studied retrospectively. Eleven consecutive patients had had open reduction and internal fixation with the modified technique using Cable Grip System, of whom, five males and six females with an average age of 60.9 years (range, 29-81 years). All fractures occurred from direct fall onto the knee. The average time from injury to surgery was 6.1days (range, 2-12days). The range of motion (ROM) was measured in degrees by goniometry at postoperative intervals of 1, 2, 4, 12, and 48 weeks; Knee function was evaluated using the Rasmussen scores at final follow-up. No patients had nonunion, loss of reduction, migration of wire, irritation from the implant and fixation breakage during the follow-up period. Recovery of ROM was achieved at 12 weeks, with the average ROM at 1 week was 72° (range, 65°-78°), 86.4° (range, 78°-92°) at 2 weeks, 115.5° (range, 103°-122°) at 4 weeks, 129.6° (range, 122°-133°) at 12 weeks, 134.5° (range, 129°-139°) at 48 weeks after the operation. Concerning the knee function outcome assessment, all patients showed excellent results at final follow-up. The average Rasmussen scores was 27.9 out of 30 (range, 27-29). The modified tension band technique combined with cable cerclage using Cable Grip System for displaced inferior patellar pole fractures can provide stable fixation with excellent results in knee function, allows for immediate mobilization and early weight-bearing, which is a simple and valuable technique in routine clinical practice. Copyright © 2017 Elsevier Ltd. All rights reserved.

  19. Discrepancies between conformational distributions of a polyalanine peptide in solution obtained from molecular dynamics force fields and amide I' band profiles.

    Science.gov (United States)

    Verbaro, Daniel; Ghosh, Indrajit; Nau, Werner M; Schweitzer-Stenner, Reinhard

    2010-12-30

    Structural preferences in the unfolded state of peptides determined by molecular dynamics still contradict experimental data. A remedy in this regard has been suggested by MD simulations with an optimized Amber force field ff03* ( Best, R. Hummer, G. J. Phys. Chem. B 2009 , 113 , 9004 - 9015 ). The simulations yielded a statistical coil distribution for alanine which is at variance with recent experimental results. To check the validity of this distribution, we investigated the peptide H-A(5)W-OH, which with the exception of the additional terminal tryptophan is analogous to the peptide used to optimize the force fields ff03*. Electronic circular dichroism, vibrational circular dichroism, and infrared spectroscopy as well as J-coupling constants obtained from NMR experiments were used to derive the peptide's conformational ensemble. Additionally, Förster resonance energy transfer between the terminal chromophores of the fluorescently labeled peptide analogue H-Dbo-A(5)W-OH was used to determine its average length, from which the end-to-end distance of the unlabeled peptide was estimated. Qualitatively, the experimental (3)J(H(N),C(α)), VCD, and ECD indicated a preference of alanine for polyproline II-like conformations. The experimental (3)J(H(N),C(α)) for A(5)W closely resembles the constants obtained for A(5). In order to quantitatively relate the conformational distribution of A(5) obtained with the optimized AMBER ff03* force field to experimental data, the former was used to derive a distribution function which expressed the conformational ensemble as a mixture of polyproline II, β-strand, helical, and turn conformations. This model was found to satisfactorily reproduce all experimental J-coupling constants. We employed the model to calculate the amide I' profiles of the IR and vibrational circular dichroism spectrum of A(5)W, as well as the distance between the two terminal peptide carbonyls. This led to an underestimated negative VCD couplet and an

  20. Study on functional relationships between ergonomics indexes of manual performance

    Science.gov (United States)

    Hu, Hui-Min; Ding, Li; Chen, Shou-Ping; Yang, Chun-Xin; Yuan, Xiu-Gan

    This paper investigates functional relationships between some of the key ergonomics indexes in manual performance, and attempts to condense the ergonomics appraisal indexes system and thus evaluate hand performance wearing EVA (extravehicular activity) glove, design and improve EVA glove's performance. Four types of ergonomics indexes were studied, i.e., dexterity, tactile sensibility (TS), strength and fatigue. Two test items of insert sticks into a holes-board (ISIHB) and nuts-bolts assembly task (NBAT) were used to measure dexterity, while shape discrimination (SD) was employed for TS, and grip force (GF) for strength and fatigue. The variables measured in this investigation included accomplishing time (AT) of ISIHB and NBAT, correct rate (CR) of SD, maximal grip force (MGF), instant grip force (IGF) and endurance time of grip force (ETGF). Experiments were conducted on 31 undergraduates (eight female and 23 male) with two experiment conditions of bare-hand group and gloved hand group. Results demonstrated that dexterity and TS performance of gloved hand group declined significantly compared with those of bare-hand group (pfatigue between two conditions (p>0.05). Four effective functional relationships were developed between four pairs of ergonomics indexes in bare-hand group. In gloved hand group, in addition to above-mentioned four pairs of relationships, another formula was found, which was y^=0.02061+0.01233x ( p<0.01, dexterity and TS).

  1. Scratch direction and threshold force in nanoscale scratching using atomic force microscopes

    Energy Technology Data Exchange (ETDEWEB)

    Tseng, Ampere A., E-mail: ampere.tseng@asu.edu [Department of Materials Science and Engineering, National Taiwan University of Science and Technology, Taipei 106, Taiwan (China); Kuo, Chung-Feng Jeffrey; Jou, Shyankay [Department of Materials Science and Engineering, National Taiwan University of Science and Technology, Taipei 106, Taiwan (China); Nishimura, Shinya; Shirakashi, Jun-ichi [Department of Electrical and Electronic Engineering, Tokyo University of Agriculture and Technology, Tokyo 184-8588 (Japan)

    2011-09-01

    The nanoscaled tip in an AFM (atomic force microscope) has become an effective scratching tool for material removing in nanofabrication. In this article, the characteristics of using a diamond-coated pyramidal tip to scratch Ni-Fe thin film surfaces was experimentally investigated with the focus on the evaluation of the influence of the scratch or scan direction on the final shape of the scratched geometry as well as the applied scratch force. Results indicated that both the scratched profile and the scratch force were greatly affected by the scratch direction. It has been found that, to minimize the formation of protuberances along the groove sides and to have a better control of the scratched geometry, the tip face should be perpendicular to the scratching direction, which is also known as orthogonal cutting condition. To demonstrate the present findings, three groove patterns have been scratched with the tip face perpendicular to the scratching direction and very little amount of protuberances was observed. The threshold scratch force was also predicted based on the Hertz contact theory. Without considering the surface friction and adhesive forces between the tip and substrate, the threshold force predicted was twice smaller than the measurement value. Finally, recommendations for technical improvement and research focuses are provided.

  2. Scratch direction and threshold force in nanoscale scratching using atomic force microscopes

    International Nuclear Information System (INIS)

    Tseng, Ampere A.; Kuo, Chung-Feng Jeffrey; Jou, Shyankay; Nishimura, Shinya; Shirakashi, Jun-ichi

    2011-01-01

    The nanoscaled tip in an AFM (atomic force microscope) has become an effective scratching tool for material removing in nanofabrication. In this article, the characteristics of using a diamond-coated pyramidal tip to scratch Ni-Fe thin film surfaces was experimentally investigated with the focus on the evaluation of the influence of the scratch or scan direction on the final shape of the scratched geometry as well as the applied scratch force. Results indicated that both the scratched profile and the scratch force were greatly affected by the scratch direction. It has been found that, to minimize the formation of protuberances along the groove sides and to have a better control of the scratched geometry, the tip face should be perpendicular to the scratching direction, which is also known as orthogonal cutting condition. To demonstrate the present findings, three groove patterns have been scratched with the tip face perpendicular to the scratching direction and very little amount of protuberances was observed. The threshold scratch force was also predicted based on the Hertz contact theory. Without considering the surface friction and adhesive forces between the tip and substrate, the threshold force predicted was twice smaller than the measurement value. Finally, recommendations for technical improvement and research focuses are provided.

  3. Simultaneous measurement of dynamic force and spatial thin film thickness between deformable and solid surfaces by integrated thin liquid film force apparatus.

    Science.gov (United States)

    Zhang, Xurui; Tchoukov, Plamen; Manica, Rogerio; Wang, Louxiang; Liu, Qingxia; Xu, Zhenghe

    2016-11-09

    Interactions involving deformable surfaces reveal a number of distinguishing physicochemical characteristics that do not exist in interactions between rigid solid surfaces. A unique fully custom-designed instrument, referred to as integrated thin liquid film force apparatus (ITLFFA), was developed to study the interactions between one deformable and one solid surface in liquid. Incorporating a bimorph force sensor with interferometry, this device allows for the simultaneous measurement of the time-dependent interaction force and the corresponding spatiotemporal film thickness of the intervening liquid film. The ITLFFA possesses the specific feature of conducting measurement under a wide range of hydrodynamic conditions, with a displacement velocity of deformable surfaces ranging from 2 μm s -1 to 50 mm s -1 . Equipped with a high speed camera, the results of a bubble interacting with hydrophilic and partially hydrophobic surfaces in aqueous solutions indicated that ITLFFA can provide information on interaction forces and thin liquid film drainage dynamics not only in a stable film but also in films of the quick rupture process. The weak interaction force was extracted from a measured film profile. Because of its well-characterized experimental conditions, ITLFFA permits the accurate and quantitative comparison/validation between measured and calculated interaction forces and temporal film profiles.

  4. The use of self-gripping (Progrip™) mesh during laparoscopic total extraperitoneal (TEP) inguinal hernia repair: a prospective feasibility and long-term outcomes study.

    Science.gov (United States)

    Bresnahan, Erin; Bates, Andrew; Wu, Andrew; Reiner, Mark; Jacob, Brian

    2015-09-01

    The use of self-gripping mesh during laparoscopic TEP inguinal hernia repairs may eliminate the need for any additional fixation, and thus reduce post-operative pain without the added concern for mesh migration. Long-term outcomes are not yet prospectively studied in a controlled fashion. Under IRB approval, from January 2011-April 2013, 91 hernias were repaired laparoscopically with self-gripping mesh without additional fixation. Patients were followed for at least 1 year. Demographics and intraoperative data (defect location, size, and mesh deployment time) are recorded. VAS is used in the recovery room (RR) to score pain, and the Carolinas Comfort Scale ™ (CCS), a validated 0-5 pain/quality of life (QoL) score where a mean score of >1.0 means symptomatic pain, is employed at 2 weeks and at 1 year. Morbidities, narcotic usage, days to full activity and return to work, and CCS scores are reported. Sixty two patients, with 91 hernias repaired with self-gripping mesh, completed follow-up at a mean time period of 14.8 months. Seventeen hernias were direct defects (average size 3.0 cm). Mesh deployment time was 193.7 s. RR pain was 1.1/10 using a VAS. Total average oxycodone/acetaminophen (5 mg/325 mg) usage = 5.0 tablets, days to full activity was 1.6, and return to work was 4.2 days. Thirteen small asymptomatic seromas were palpated without any recurrences or groin tenderness, and all seromas resolved by the 6 month visit. Transient testis discomfort was reported in five patients. Urinary retention was 3.2%. Mean CCS™ scores at the first visit for groin pain laying, bending, sitting, walking, and step-climbing were 0.2, 0.5, 0.4, 0.3, and 0.3, respectively. At the first post op visit, 4.8% had symptomatic pain (CCS > 1). At 14.8 months, no patients reported symptomatic pain with CCS scores for all 62 patients averaging 0.02, (range 0-0.43). There are no recurrences thus far. Self-gripping mesh can be safely used during laparoscopic TEP inguinal hernia repairs

  5. Approximate Stokes Drift Profiles and their use in Ocean Modelling

    Science.gov (United States)

    Breivik, Oyvind; Bidlot, Jea-Raymond; Janssen, Peter A. E. M.; Mogensen, Kristian

    2016-04-01

    Deep-water approximations to the Stokes drift velocity profile are explored as alternatives to the monochromatic profile. The alternative profiles investigated rely on the same two quantities required for the monochromatic profile, viz the Stokes transport and the surface Stokes drift velocity. Comparisons against parametric spectra and profiles under wave spectra from the ERA-Interim reanalysis and buoy observations reveal much better agreement than the monochromatic profile even for complex sea states. That the profiles give a closer match and a more correct shear has implications for ocean circulation models since the Coriolis-Stokes force depends on the magnitude and direction of the Stokes drift profile and Langmuir turbulence parameterizations depend sensitively on the shear of the profile. Of the two Stokes drift profiles explored here, the profile based on the Phillips spectrum is by far the best. In particular, the shear near the surface is almost identical to that influenced by the f-5 tail of spectral wave models. The NEMO general circulation ocean model was recently extended to incorporate the Stokes-Coriolis force along with two other wave-related effects. The ECWMF coupled atmosphere-wave-ocean ensemble forecast system now includes these wave effects in the ocean model component (NEMO).

  6. Comparing two methods to record maximal voluntary contractions and different electrode positions in recordings of forearm extensor muscle activity: Refining risk assessments for work-related wrist disorders.

    Science.gov (United States)

    Dahlqvist, Camilla; Nordander, Catarina; Granqvist, Lothy; Forsman, Mikael; Hansson, Gert-Åke

    2018-01-01

    Wrist disorders are common in force demanding industrial repetitive work. Visual assessment of force demands have a low reliability, instead surface electromyography (EMG) may be used as part of a risk assessment for work-related wrist disorders. For normalization of EMG recordings, a power grip (hand grip) is often used as maximal voluntary contraction (MVC) of the forearm extensor muscles. However, the test-retest reproducibility is poor and EMG amplitudes exceeding 100% have occasionally been recorded during work. An alternative MVC is resisted wrist extension, which may be more reliable. To compare hand grip and resisted wrist extension MVCs, in terms of amplitude and reproducibility, and to examine the effect of electrode positioning. Twelve subjects participated. EMG from right forearm extensors, from four electrode pairs, was recorded during MVCs, on three separate occasions. The group mean EMG amplitudes for resisted wrist extension were 1.2-1.7 times greater than those for hand grip. Resisted wrist extension showed better reproducibility than hand grip. The results indicate that the use of resisted wrist extension is a more accurate measurement of maximal effort of wrist extensor contractions than using hand grip and should increase the precision in EMG recordings from forearm extensor muscles, which in turn will increase the quality of risk assessments that are based on these.

  7. Synaptic and functional linkages between spinal premotor interneurons and hand-muscle activity during precision grip

    Directory of Open Access Journals (Sweden)

    Tomohiko eTakei

    2013-04-01

    Full Text Available Grasping is a highly complex movement that requires the coordination of a number of hand joints and muscles. Previous studies showed that spinal premotor interneurons (PreM-INs in the primate cervical spinal cord have divergent synaptic effects on hand motoneurons and that they might contribute to hand-muscle synergies. However, the extent to which these PreM-IN synaptic connections functionally contribute to modulating hand-muscle activity is not clear. In this paper, we explored the contribution of spinal PreM-INs to hand-muscle activation by quantifying the synaptic linkage (SL and functional linkage (FL of the PreM-INs with hand-muscle activities. The activity of 23 PreM-INs was recorded from the cervical spinal cord (C6–T1, with EMG signals measured simultaneously from hand and arm muscles in two macaque monkeys performing a precision grip task. Spike-triggered averages (STAs of rectified EMGs were compiled for 456 neuron–muscle pairs; 63 pairs showed significant post-spike effects (i.e., SL. Conversely, 231 of 456 pairs showed significant cross-correlations between the IN firing rate and rectified EMG (i.e., FL. Importantly, a greater proportion of the neuron–muscle pairs with SL showed FL (43/63 pairs, 68% compared with the pairs without SL (203/393, 52%, and the presence of SL was significantly associated with that of FL. However, a significant number of pairs had SL without FL (SL∩!FL, n = 20 or FL without SL (!SL∩FL, n = 203, and the proportions of these incongruities exceeded the number expected by chance. These results suggested that spinal PreM-INs function to significantly modulate hand-muscle activity during precision grip, but the contribution of other neural structures is also needed to recruit an adequate combination of hand-muscle motoneurons.

  8. Force Control and Nonlinear Master-Slave Force Profile to Manage an Admittance Type Multi-Fingered Haptic User Interface

    Energy Technology Data Exchange (ETDEWEB)

    Anthony L. Crawford

    2012-08-01

    Natural movements and force feedback are important elements in using teleoperated equipment if complex and speedy manipulation tasks are to be accomplished in remote and/or hazardous environments, such as hot cells, glove boxes, decommissioning, explosives disarmament, and space to name a few. In order to achieve this end the research presented in this paper has developed an admittance type exoskeleton like multi-fingered haptic hand user interface that secures the user’s palm and provides 3-dimensional force feedback to the user’s fingertips. Atypical to conventional haptic hand user interfaces that limit themselves to integrating the human hand’s characteristics just into the system’s mechanical design this system also perpetuates that inspiration into the designed user interface’s controller. This is achieved by manifesting the property differences of manipulation and grasping activities as they pertain to the human hand into a nonlinear master-slave force relationship. The results presented in this paper show that the admittance-type system has sufficient bandwidth that it appears nearly transparent to the user when the user is in free motion and when the system is subjected to a manipulation task, increased performance is achieved using the nonlinear force relationship compared to the traditional linear scaling techniques implemented in the vast majority of systems.

  9. High-resolution humidity profiles retrieved from wind profiler radar measurements

    Science.gov (United States)

    Saïd, Frédérique; Campistron, Bernard; Di Girolamo, Paolo

    2018-03-01

    The retrieval of humidity profiles from wind profiler radars has already been documented in the past 30 years and is known to be neither as straightforward and nor as robust as the retrieval of the wind velocity. The main constraint to retrieve the humidity profile is the necessity to combine measurements from the wind profiler and additional measurements (such as observations from radiosoundings at a coarser time resolution). Furthermore, the method relies on some assumptions and simplifications that restrict the scope of its application. The first objective of this paper is to identify the obstacles and limitations and solve them, or at least define the field of applicability. To improve the method, we propose using the radar capacity to detect transition levels, such as the top level of the boundary layer, marked by a maximum in the radar reflectivity. This forces the humidity profile from the free troposphere and from the boundary layer to coincide at this level, after an optimization of the calibration coefficients, and reduces the error. The resulting mean bias affecting the specific humidity profile never exceeds 0.25 g kg-1. The second objective is to explore the capability of the algorithm to retrieve the humidity vertical profiles for an operational purpose by comparing the results with observations from a Raman lidar.

  10. Factors that influence ground reaction force profiles during counter movement jumping.

    Science.gov (United States)

    Eagles, Alexander N; Sayers, Mark G; Lovell, Dale I

    2017-05-01

    The purpose of this study was to examine how hip, knee and ankle kinetics and kinematics influence effective impulse production during countermovement jumps. Eighteen semi-professional soccer players (22.8±2.2 years) volunteered to participate in the study. Participants completed three maximal countermovement jumps on two force platforms (1000 Hz) that were linked to a nine camera infrared motion capture system (500 Hz). Kinetic and kinematic data revealed jumpers who fail to achieve uniform ground reaction force curves that result in optimal impulse production during their jump always display hip adduction and or hip internal rotation during the concentric phase of the countermovement jump. The variation of hip adduction and or internal rotation likely represents failed joint transition during the concentric phase of the countermovement jump and appears to account for a non-uniform force trace seen in these jumpers. The findings suggest rehabilitation and conditioning exercises for injury prevention and performance may benefit from targeting frontal and transverse plane movement.

  11. Aerodynamics profile not in stationary flow

    Directory of Open Access Journals (Sweden)

    А.А. Загорулько

    2006-02-01

    Full Text Available  Consider the question about influence of unsteady flight on the size of drag and lift coefficients of theaerodynamic profile. Distinctive features of this investigation are obtaining data about aerodynamic drag chancing in process unsteady on high angle at attack and oscillation profile in subsonic and transonic flight. Given analysis of oscillation profile show, that dynamic loops accompany change of lift and dray force. The researches show that it is necessary to clarity the mathematic model of the airplane flight dynamics by introducing numbers, with take into account unsteady effects.

  12. The relationship between jaw-opening force and the cross-sectional area of the suprahyoid muscles in healthy elderly.

    Science.gov (United States)

    Kajisa, E; Tohara, H; Nakane, A; Wakasugi, Y; Hara, K; Yamaguchi, K; Yoshimi, K; Minakuchi, S

    2018-03-01

    We conducted a clinical cross-sectional study to examine the relationship between jaw-opening force and the cross-sectional area of the suprahyoid muscles and whole skeletal muscle mass. Subjects were healthy 39 males and 51 females without dysphagia and sarcopenia, aged 65 years and older. Jaw-opening force was measured three times using a jaw-opening sthenometer; the maximum of these three was taken as the measurement value. The cross-sectional area of the geniohyoid and anterior belly of the digastric muscles were evaluated using ultrasonography. The skeletal muscle mass index, gait speed and grip strength were evaluated according to the diagnostic criteria of the Asian Working Group for Sarcopenia. For each sex, a multiple regression analysis determined the factors that affect jaw-opening force. Jaw-opening force was associated with the cross-sectional area of the geniohyoid muscle in males (regression coefficient [β] = 0.441, 95% confidence interval [CI] = 14.28-56.09) and females (β = 0.28, 95% CI = 3.10-54.57). Furthermore, in females only, jaw-opening force was associated with the skeletal muscle mass index (β = 0.40, 95% CI = 3.67-17.81). In contrast, jaw-opening force was not associated with the cross-sectional area of the anterior belly of the digastric muscle in either sex. In healthy elderly males and females, jaw-opening force was positively associated with the cross-sectional area of the geniohyoid muscle. However, the jaw-opening force was positively associated with the skeletal muscle mass index only in females. © 2017 John Wiley & Sons Ltd.

  13. Engineering flow states with localized forcing in a thin Marangoni-driven inclined film.

    Science.gov (United States)

    Levy, Rachel; Rosenthal, Stephen; Wong, Jeffrey

    2010-11-01

    Numerical simulations of lubrication models provide clues for experimentalists about the development of wave structures in thin liquid films. We analyze numerical simulations of a lubrication model for an inclined thin liquid film modified by Marangoni forces due to a thermal gradient and additional localized forcing heating the substrate. Numerical results can be explained through connections to theory for hyperbolic conservation laws predicting wave fronts from Marangoni-driven thin films without forcing. We demonstrate how a variety of forcing profiles, such as gaussian, rectangular, and triangular, affect the formation of downstream transient structures, including an N wave not commonly discussed in the context of thin films. Simulations employing a controlled approximation of a compressive-undercompressive wave pair demonstrate possibilities for applications of localized forcing as microfluidic valve. In the simulations, localized forcing provides a control parameter that can be used to determine mass flux and film profiles.

  14. Evaluation of finger A3 pulley rupture in the crimp grip position - a magnetic resonance imaging cadaver study

    Energy Technology Data Exchange (ETDEWEB)

    Bayer, Thomas; Uder, Michael; Janka, Rolf [University of Erlangen-Nuremberg, Department of Radiology, Erlangen (Germany); Adler, Werner [University of Erlangen-Nuremberg, Department of Biometry and Epidemiology, Erlangen (Germany); Schweizer, Andreas [Balgrist, University of Zurich, Department of Orthopaedics, Zurich (Switzerland); Schoeffl, Isabelle [Klinikum Bamberg, Department of Pediatrics, Bamberg (Germany)

    2015-09-15

    The correct diagnosis of an A3 pulley rupture is challenging for musculoskeletal radiologists. An A3 pulley rupture should in theory influence the shape of the proximal interphalangeal joint volar plate (VP) and the amount of bowstringing at level of the VP during finger flexion. The purpose of this study was to perform MRI with metric analysis of the VP configuration and VP bowstringing in cadaver fingers in the crimp grip position and to determine cut points for A3 pulley rupture. MRI in the crimp grip position was performed in 21 cadaver fingers with artificially created flexor tendon pulley tears (fingers with A3 pulley rupture n = 16, fingers without A3 pulley rupture n = 5). The distances of the translation of the VP relative to the middle phalanx base, the distances between the flexor tendons and the VP body, and the distances between the flexor tendon and bone (TB) were measured. Statistical analysis showed significantly lower VP translation distances and significantly higher VP tendon distances if the A3 pulley was ruptured. A2 TB and A4 TB distances did not differ significantly in specimens with and without A3 pulley rupture. The optimal cut points for A3 pulley rupture were a VP translation distance <2.8 mm and a VP tendon distance >1.4 mm. Reduction of the VP translation distance and augmentation of the VP tendon distance are suitable indirect signs of A3 pulley rupture. (orig.)

  15. Grip op werkstress. Mindfulness ontstresst maatschappelijk werkers

    Directory of Open Access Journals (Sweden)

    Jen van Horen

    2014-03-01

    Full Text Available Taking control over work related stress. Mindfulness destresses social workersStress is a major social problem. Due to the increasing workload and the content of the work, social workers are at risk to develop stress (symptoms. The physical and psychological consequences of prolonged stress are serious. By living healthy, optimize working conditions and applying mindfulness, stress can be reduced. Mindfulness is an effective and useful way to reduce stress. It increases the resistance of workers against stress, improves brainfunctions and therefore has a positive effect on the performance. These effects are great, but they are still weakly methodologically substantiated. A pilot project within the youthcare though, was enthusiastically received and proves to be effective against stress symptoms. The exercises that are part of this pilot fit well with the needs of employees. For organizations mindfulnesstrainings are a time-and cost-effective way of structural stress prevention.Grip op werkstress. Mindfulness ontstresst maatschappelijk werkersStress is een omvangrijk maatschappelijk probleem. Door de toenemende werkdruk en de inhoud van het werk zijn maatschappelijk werkers een risicogroep om stress en stressklachten te ontwikkelen. De fysieke en psychische gevolgen die langdurige stress met zich meebrengt zijn ernstig. Door gezond te leven, de arbeidsomstandigheden te optimaliseren en mindfulness toe te passen kan stress terug worden gedrongen. Mindfulness is een effectieve en bruikbare manier om stress te verminderen. Het vergroot de weerbaarheid van werknemers tegen stress, het verbetert de hersenwerking en heeft daardoor een positief effect op het functioneren. Grote effecten dus, maar wel nog methodologisch zwak onderbouwd. Een pilot binnen de jeugdzorg op het gebied van mindfulness is enthousiast ontvangen en blijkt effectief tegen stressklachten. De oefeningen die onderdeel uitmaken van deze pilot sluiten goed aan bij de behoeften van

  16. TEMPS-A[P] temperament profile related to professional choice. Differences between applicants to become a cadet officer in the Italian Air Force or Navy.

    Science.gov (United States)

    Rovai, Luca; Maremmani, Angelo Giovanni Icro; Leonardi, Annalisa; Bacciardi, Silvia; Rugani, Fabio; Dell'Osso, Liliana; Akiskal, Hagop S; Maremmani, Icro

    2013-02-15

    Temperament appears to be a factor involved in professional attitudes. The most impressive findings are those on the importance of cyclothymia in art and of hyperthymia in leadership. In this study we raise the issue of whether the relationship between hyperthymic temperament and the choice of a military career, previously reported among Italian Air Force applicants, can be extended to another military service such as the Italian Navy. We compared temperaments between those who had applied to become a cadet officer in the Italian Air Force or in the Italian Navy, with special reference to gender differences and the ability of the two types of applicants to pass the psychiatric examination for admission that we had recently assessed in the Italian Air Force. Hyperthymic traits were well represented in both these armed services. Navy applicants differed from air-force applicants in obtaining higher depressive, cyclothymic and irritable scores. Navy applicants who passed the psychiatric entrance examination (PEE) showed the same incidence of hyperthymic temperament as their Air Force counterparts, but higher depressive, cyclothymic and irritable scores. Considering gender, among Air Force applicants depressive traits were better represented in males; conversely, among Navy applicants they were better represented in females. If we consider gender together with PEE results, the highest hyperthymic scores were more frequently found among males who passed and females who failed to pass the PEE. On the other hand, a greater number of cyclothymic traits were found in females who passed and males who failed to pass the PEE. It was confirmed that hyperthymic temperament represents the temperamental profile of those who aim to become a cadet officer in the Italian armed forces. This study further supports the idea that hyperthymic traits bring distinct advantages in a professional field, such as a military career, which is closely related to leadership. Copyright © 2012

  17. Development of a Tactile Sensor Array

    DEFF Research Database (Denmark)

    Marian, Nicolae; Drimus, Alin; Bilberg, Arne

    2010-01-01

    Flexible grasping robots are needed for enabling automated, profitable and competitive production of small batch sizes including complex handling processes of often fragile objects. This development will create new conditions for value-adding activities in the production of the future world....... The paper describes the related research work we have developed for sensor design, exploration and control for a robot gripping system, in order to analyze normal forces applied on the tactile pixels for gripping force control and generate tactile images for gripping positioning and object recognition....... Section 1 gives an introduction of principles and technologies in tactile sensing for robot grippers. Section 2 presents the sensor cell (taxel) and array design and characterization. Section 3 introduces object recognition and shape analysis ideas showing a few preliminary examples, where geometrical...

  18. Can shoulder joint reaction forces be estimated by neural networks?

    NARCIS (Netherlands)

    de Vries, W.H.K.; Veeger, H.E.J.; Baten, C.T.M.; van der Helm, F.C.T.

    2016-01-01

    To facilitate the development of future shoulder endoprostheses, a long term load profile of the shoulder joint is desired. A musculoskeletal model using 3D kinematics and external forces as input can estimate the mechanical load on the glenohumeral joint, in terms of joint reaction forces. For long

  19. Adapting haptic guidance authority based on user grip

    NARCIS (Netherlands)

    Smisek, J.; Mugge, W.; Smeets, J.B.J.; Van Paassen, M.M.; Schiele, A

    2014-01-01

    Haptic guidance systems support the operator in task execution using additional forces on the input device. Scaling of the guidance forces determines the control authority of the support system. As task complexity may vary, one level of the guidance scaling may be insufficient, and adaptation of the

  20. Tracking upper limbs fatigue by means of electronic dynamometry

    Directory of Open Access Journals (Sweden)

    Fernando Max Lima

    2015-06-01

    Full Text Available This study aimed to identify useful electronic grip dynamometry parameters to track differences between trained (TR and untrained (UT participants, and between dominant (DO and non-dominant (ND limbs as a consequence of upper limbs muscle fatigue following 10 RM tests of the brachial biceps. This experimental study with transversal design involved 18 young adult males, of whom 9 were untrained and 9 were experienced in resistance training.Isometric grip force was evaluated (30 seconds long previous and after 10RM tests by means of a G200 Model grip dynamometer with precision load cell (Biometrics(r. Significant differences between initial and final measurements were found only for trained participants: Peak force for TR-DO (67.1 vs 55.5 kgf, p = .0277; Raw average for TR-DO (46.96 vs 42.22 kgf, p = .0464, and for TR-ND (40.34 vs 36.13 kgf, p = .0277. Electronic grip dynamometry efficiently identified upper limbs fatigue in trained participants, being raw average measurements the best parameter.

  1. Imaging surface nanobubbles at graphite–water interfaces with different atomic force microscopy modes

    International Nuclear Information System (INIS)

    Yang, Chih-Wen; Lu, Yi-Hsien; Hwang, Ing-Shouh

    2013-01-01

    We have imaged nanobubbles on highly ordered pyrolytic graphite (HOPG) surfaces in pure water with different atomic force microscopy (AFM) modes, including the frequency-modulation, the tapping, and the PeakForce techniques. We have compared the performance of these modes in obtaining the surface profiles of nanobubbles. The frequency-modulation mode yields a larger height value than the other two modes and can provide more accurate measurement of the surface profiles of nanobubbles. Imaging with PeakForce mode shows that a nanobubble appears smaller and shorter with increasing peak force and disappears above a certain peak force, but the size returns to the original value when the peak force is reduced. This indicates that imaging with high peak forces does not cause gas removal from the nanobubbles. Based on the presented findings and previous AFM observations, the existing models for nanobubbles are reviewed and discussed. The model of gas aggregate inside nanobubbles provides a better explanation for the puzzles of the high stability and the contact angle of surface nanobubbles. (paper)

  2. Does a history of physical exposures at work affect hand-grip strength in midlife?

    DEFF Research Database (Denmark)

    Møller, Anne; Reventlow, Susanne; Hansen, Åse Marie

    2013-01-01

    were non-linear and primarily positive among men. Among women, the associations were non-linear and, according to ton-years, primarily negatively associated with HGS but statistically insignificant. CONCLUSION: A history of physical exposures at work explained only a minor part of the variation in HGS......OBJECTIVE: The aim of this cohort study was to examine associations between physical exposures throughout working life and hand-grip strength (HGS) in midlife. METHODS: The Copenhagen Aging and Midlife Biobank (CAMB) provided data about employment and HGS for 3843 Danes. Individual job histories......, including duration of employment in specific jobs, were assigned exposures from a job exposure matrix. Exposures were standardized to ton-years (lifting 1000 kg each day in one year), stand-years (standing/walking for six hours each day in one year) and kneel-years (kneeling for one hour each day in one...

  3. Object properties and cognitive load in the formation of associative memory during precision lifting.

    Science.gov (United States)

    Li, Yong; Randerath, Jennifer; Bauer, Hans; Marquardt, Christian; Goldenberg, Georg; Hermsdörfer, Joachim

    2009-01-03

    When we manipulate familiar objects in our daily life, our grip force anticipates the physical demands right from the moment of contact with the object, indicating the existence of a memory for relevant object properties. This study explores the formation and consolidation of the memory processes that associate either familiar (size) or arbitrary object features (color) with object weight. In the general task, participants repetitively lifted two differently weighted objects (580 and 280 g) in a pseudo-random order. Forty young healthy adults participated in this study and were randomly distributed into four groups: Color Cue Single task (CCS, blue and red, 9.8(3)cm(3)), Color Cue Dual task (CCD), No Cue (NC) and Size Cue (SC, 9.8(3) and 6(3)cm(3)) group. All groups performed a repetitive precision grasp-lift task and were retested with the same protocol after a 5-min pause. The CCD group was also required to simultaneously perform a memory task during each lift of differently weighted objects coded by color. The results show that groups lifting objects with arbitrary or familiar features successfully formed the association between object weight and manipulated object features and incorporated this into grip force programming, as observed in the different scaling of grip force and grip force rate for different object weights. An arbitrary feature, i.e., color, can be sufficiently associated with object weight, however with less strength than the familiar feature of size. The simultaneous memory task impaired anticipatory force scaling during repetitive object lifting but did not jeopardize the learning process and the consolidation of the associative memory.

  4. The cost of leg forces in bipedal locomotion: a simple optimization study.

    Directory of Open Access Journals (Sweden)

    John R Rebula

    Full Text Available Simple optimization models show that bipedal locomotion may largely be governed by the mechanical work performed by the legs, minimization of which can automatically discover walking and running gaits. Work minimization can reproduce broad aspects of human ground reaction forces, such as a double-peaked profile for walking and a single peak for running, but the predicted peaks are unrealistically high and impulsive compared to the much smoother forces produced by humans. The smoothness might be explained better by a cost for the force rather than work produced by the legs, but it is unclear what features of force might be most relevant. We therefore tested a generalized force cost that can penalize force amplitude or its n-th time derivative, raised to the p-th power (or p-norm, across a variety of combinations for n and p. A simple model shows that this generalized force cost only produces smoother, human-like forces if it penalizes the rate rather than amplitude of force production, and only in combination with a work cost. Such a combined objective reproduces the characteristic profiles of human walking (R² = 0.96 and running (R² = 0.92, more so than minimization of either work or force amplitude alone (R² = -0.79 and R² = 0.22, respectively, for walking. Humans might find it preferable to avoid rapid force production, which may be mechanically and physiologically costly.

  5. Control Of Motor Unit Firing During Step-Like Increases In Voluntary Force

    Directory of Open Access Journals (Sweden)

    Xiaogang eHu

    2014-09-01

    Full Text Available In most skeletal muscles, force is generated by a combination of motor unit (MU recruitment and increases in the firing rate of previously active MUs. Two contrasting patterns of firing rate organization have been reported. In the first pattern, the earliest recruited MUs reach the highest firing rates as force is increased, and later recruited MUs fire at lower rates. When firing rate of multiple MUs are superimposed, these rate trajectories form a concentric layered profile termed ‘onion skin’. In the second pattern, called ‘reverse onion skin’, later recruited MUs reach higher firing rates, and crossing of firing rate trajectories for recorded MUs is common (although such trajectories are assembled routinely from different trials. Our present study examined the firing rate organization of concurrently active MUs of the first dorsal interosseous muscle during serial, step-like increases in isometric abduction forces. We used a surface sensor array coupled with MU discrimination algorithms to characterize MU firing patterns. Our objective was to determine whether ‘onion skin’ profiles are contingent upon the force trajectory of the motor task, examined here using step-like increases of force output, and also whether they are manifested at different force levels.Our results revealed that the overall ‘onion skin’ firing rate profile was retained as the force level increased with each force step up to 15% MVC. However, the distribution of firing rates across MUs was compressed with increasing force, and overlapping firing rate of units were observed. This rate compression was largely due to rate saturation of the relatively high frequency discharging MUs.Our results reflect flexible firing patterns across MUs at different levels of excitation drive. It is also evident that many units did not follow all the step increases consistently. This failure to track firing rate increases at higher forces could be due to an intrinsically

  6. In vivo recording of aerodynamic force with an aerodynamic force platform: from drones to birds.

    Science.gov (United States)

    Lentink, David; Haselsteiner, Andreas F; Ingersoll, Rivers

    2015-03-06

    Flapping wings enable flying animals and biomimetic robots to generate elevated aerodynamic forces. Measurements that demonstrate this capability are based on experiments with tethered robots and animals, and indirect force calculations based on measured kinematics or airflow during free flight. Remarkably, there exists no method to measure these forces directly during free flight. Such in vivo recordings in freely behaving animals are essential to better understand the precise aerodynamic function of their flapping wings, in particular during the downstroke versus upstroke. Here, we demonstrate a new aerodynamic force platform (AFP) for non-intrusive aerodynamic force measurement in freely flying animals and robots. The platform encloses the animal or object that generates fluid force with a physical control surface, which mechanically integrates the net aerodynamic force that is transferred to the earth. Using a straightforward analytical solution of the Navier-Stokes equation, we verified that the method is accurate. We subsequently validated the method with a quadcopter that is suspended in the AFP and generates unsteady thrust profiles. These independent measurements confirm that the AFP is indeed accurate. We demonstrate the effectiveness of the AFP by studying aerodynamic weight support of a freely flying bird in vivo. These measurements confirm earlier findings based on kinematics and flow measurements, which suggest that the avian downstroke, not the upstroke, is primarily responsible for body weight support during take-off and landing.

  7. Effect of low appendicular lean mass, grip strength, and gait speed on the functional outcome after surgery for distal radius fractures.

    Science.gov (United States)

    Roh, Young Hak; Noh, Jung Ho; Gong, Hyun Sik; Baek, Goo Hyun

    2017-12-01

    Patients with low appendicular lean mass plus slow gait speed or weak grip strength are at risk for poor functional recovery after surgery for distal radius fracture, even when they have similar radiologic outcomes. Loss of skeletal muscle mass and consequent loss in muscle function associate with aging, and this condition negatively impacts the activities of daily living and increases elderly individuals' frailty to falls. Thus, patients with low appendicular lean mass would show different functional recovery compared to those without this condition after surgery for distal radius fracture (DRF). This study compares the functional outcomes after surgery for DRF in patients with or without low appendicular lean mass plus slowness or weakness. A total of 157 patients older than 50 years of age with a DRF treated via volar plate fixation were enrolled in this prospective study. A definition of low appendicular lean mass with slowness or weakness was based on the consensus of the Asian Working Group for Sarcopenia. The researchers compared functional assessments (wrist range of motion and Michigan Hand Questionnaire [MHQ]) and radiographic assessments (radial inclination, volar tilt, ulnar variance, and articular congruity) 12 months after surgery between patients with and without low appendicular lean mass plus slowness or weakness. Multivariable regression analyses were performed to determine whether appendicular lean mass, grip strength, gait speed, patient demographic, or injury characteristics accounted for the functional outcomes. Patients with low appendicular lean mass plus slowness or weakness showed a significantly lower recovery of MHQ score than those in the control group throughout 12 months. There was no significant difference in the range of motion between the groups. The radiologic outcomes showed no significant difference between groups in terms of volar tilt, radial inclination, or ulnar variance. According to multivariable regression analysis

  8. Probing Anisotropic Surface Properties of Molybdenite by Direct Force Measurements.

    Science.gov (United States)

    Lu, Zhenzhen; Liu, Qingxia; Xu, Zhenghe; Zeng, Hongbo

    2015-10-27

    Probing anisotropic surface properties of layer-type mineral is fundamentally important in understanding its surface charge and wettability for a variety of applications. In this study, the surface properties of the face and the edge surfaces of natural molybdenite (MoS2) were investigated by direct surface force measurements using atomic force microscope (AFM). The interaction forces between the AFM tip (Si3N4) and face or edge surface of molybdenite were measured in 10 mM NaCl solutions at various pHs. The force profiles were well-fitted with classical DLVO (Derjaguin-Landau-Verwey-Overbeek) theory to determine the surface potentials of the face and the edge surfaces of molybdenite. The surface potentials of both the face and edge surfaces become more negative with increasing pH. At neutral and alkaline conditions, the edge surface exhibits more negative surface potential than the face surface, which is possibly due to molybdate and hydromolybdate ions on the edge surface. The point of zero charge (PZC) of the edge surface was determined around pH 3 while PZC of the face surface was not observed in the range of pH 3-11. The interaction forces between octadecyltrichlorosilane-treated AFM tip (OTS-tip) and face or edge surface of molybdenite were also measured at various pHs to study the wettability of molybdenite surfaces. An attractive force between the OTS-tip and the face surface was detected. The force profiles were well-fitted by considering DLVO forces and additional hydrophobic force. Our results suggest the hydrophobic feature of the face surface of molybdenite. In contrast, no attractive force between the OTS-tip and the edge surface was detected. This is the first study in directly measuring surface charge and wettability of the pristine face and edge surfaces of molybdenite through surface force measurements.

  9. Continuous theta-burst stimulation over the dorsal premotor cortex interferes with associative learning during object lifting.

    Science.gov (United States)

    Nowak, Dennis A; Berner, Julia; Herrnberger, Bärbel; Kammer, Thomas; Grön, Georg; Schönfeldt-Lecuona, Carlos

    2009-04-01

    When lifting objects of different mass, humans scale grip force according to the expected mass. In this context, humans are able to associate a sensory cue, such as a colour, to a particular mass of an object and link this association to the grip forces necessary for lifting. Here, we study the role of the dorsal premotor cortex (PMd) in setting-up an association between a colour cue and a particular mass to be lifted. Healthy right-handed subjects used a precision grip between the index finger and thumb to lift two different masses. Colour cues provided information about which of the two masses subjects would have to lift. Subjects first performed a series of lifts with the right hand to establish a stable association between a colour cue and a mass, followed by 20sec of continuous high frequency repetitive trancranial magnetic stimulation using a recently developed protocol (continuous theta-burst stimulation, cTBS) over (i) the left primary motor cortex, (ii) the left PMd and (iii) the left occipital cortex to be commenced by another series of lifts with either the right or left hand. cTBS over the PMd, but not over the primary motor cortex or O1, disrupted the predictive scaling of isometric finger forces based on colour cues, irrespective of whether the right or left hand performed the lifts after the stimulation. Our data highlight the role of the PMd to generalize and maintain associative memory processes relevant for predictive control of grip forces during object manipulation.

  10. Ground reaction force comparison of controlled resistance methods to isoinertial loading of the squat exercise - biomed 2010.

    Science.gov (United States)

    Paulus, David C; Reynolds, Michael C; Schilling, Brian K

    2010-01-01

    The ground reaction force during the concentric (raising) portion of the squat exercise was compared to that of isoinertial loading (free weights) for three pneumatically controlled resistance methods: constant resistance, cam force profile, and proportional force control based on velocity. Constant force control showed lower ground reaction forces than isoinertial loading throughout the range of motion (ROM). The cam force profile exhibited slightly greater ground reaction forces than isoinertial loading at 10 and 40% ROM with fifty-percent greater loading at 70% ROM. The proportional force control consistently elicited greater ground reaction force than isoinertial loading, which progressively ranged from twenty to forty percent increase over isoinertial loading except for being approximately equal at 85% ROM. Based on these preliminary results, the proportional control shows the most promise for providing loading that is comparable in magnitude to isoinertial loading. This technology could optimize resistance exercise for sport-specific training or as a countermeasure to atrophy during spaceflight.

  11. Estimation of Sensory Pork Loin Tenderness Using Warner-Bratzler Shear Force and Texture Profile Analysis Measurements.

    Science.gov (United States)

    Choe, Jee-Hwan; Choi, Mi-Hee; Rhee, Min-Suk; Kim, Byoung-Chul

    2016-07-01

    This study investigated the degree to which instrumental measurements explain the variation in pork loin tenderness as assessed by the sensory evaluation of trained panelists. Warner-Bratzler shear force (WBS) had a significant relationship with the sensory tenderness variables, such as softness, initial tenderness, chewiness, and rate of breakdown. In a regression analysis, WBS could account variations in these sensory variables, though only to a limited proportion of variation. On the other hand, three parameters from texture profile analysis (TPA)-hardness, gumminess, and chewiness-were significantly correlated with all sensory evaluation variables. In particular, from the result of stepwise regression analysis, TPA hardness alone explained over 15% of variation in all sensory evaluation variables, with the exception of perceptible residue. Based on these results, TPA analysis was found to be better than WBS measurement, with the TPA parameter hardness likely to prove particularly useful, in terms of predicting pork loin tenderness as rated by trained panelists. However, sensory evaluation should be conducted to investigate practical pork tenderness perceived by consumer, because both instrumental measurements could explain only a small portion (less than 20%) of the variability in sensory evaluation.

  12. Examination of objective analysis precision using wind profiler and radiosonde network data

    Energy Technology Data Exchange (ETDEWEB)

    Mace, G.G.; Ackerman, T.P. [Penn State Univ., University Park, PA (United States)

    1996-04-01

    One of the principal research strategies that has emerged from the science team of the Atmospheric Radiation Measurement (ARM) Program is the use of a single column model (SCM). The basic assumption behind the SCM approach is that a cloud and radiation parameterization embedded in a general circulation model can be effectively tested and improved by extracting that column parameterization from the general circulation model and then driving this single column at the lateral boundaries of the column with diagnosed large-scale atmospheric forcing. A second and related assumption is that the large-scale atmospheric state, and hence the associated forcing, can be characterized directly from observations. One of the primary reasons that the Southern Great Plains (SGP) site is located in Lamont, Oklahoma, is because Lamont is at the approximate center of the NOM Wind Profiler Demonstration Array (WPDA). The assumption was that hourly average wind profiles provided by the 7 wind profilers (one Lamont and six surrounding it in a hexagon) coupled with radiosonde launches every three hours at 5 sites (Lamont plus four of the six profiler locations forming the hexagon) would be sufficient to characterize accurately the large-scale forcing at the site and thereby provide the required forcing for the SCM. The goal of this study was to examine these three assumptions.

  13. Force and Stress along Simulated Dissociation Pathways of Cucurbituril-Guest Systems.

    Science.gov (United States)

    Velez-Vega, Camilo; Gilson, Michael K

    2012-03-13

    The field of host-guest chemistry provides computationally tractable yet informative model systems for biomolecular recognition. We applied molecular dynamics simulations to study the forces and mechanical stresses associated with forced dissociation of aqueous cucurbituril-guest complexes with high binding affinities. First, the unbinding transitions were modeled with constant velocity pulling (steered dynamics) and a soft spring constant, to model atomic force microscopy (AFM) experiments. The computed length-force profiles yield rupture forces in good agreement with available measurements. We also used steered dynamics with high spring constants to generate paths characterized by a tight control over the specified pulling distance; these paths were then equilibrated via umbrella sampling simulations and used to compute time-averaged mechanical stresses along the dissociation pathways. The stress calculations proved to be informative regarding the key interactions determining the length-force profiles and rupture forces. In particular, the unbinding transition of one complex is found to be a stepwise process, which is initially dominated by electrostatic interactions between the guest's ammoniums and the host's carbonyl groups, and subsequently limited by the extraction of the guest's bulky bicyclooctane moiety; the latter step requires some bond stretching at the cucurbituril's extraction portal. Conversely, the dissociation of a second complex with a more slender guest is mainly driven by successive electrostatic interactions between the different guest's ammoniums and the host's carbonyl groups. The calculations also provide information on the origins of thermodynamic irreversibilities in these forced dissociation processes.

  14. Proceedings of the IRI task force activity 1995

    International Nuclear Information System (INIS)

    Radicella, S.M.

    1996-05-01

    The report contains the programme, conclusions and the write up of 11 presentations delivered during the International Reference Ionosphere (IRI) Task Force Activity 1995 that took place at the ICTP Trieste between 13-17 November 1995. The presentations included have been grouped in three chapters: Status report and data availability (2 presentations), Electron density profile shape below Nmax (5 presentations) and Intermediate regions (F1) electron density profile (4 presentations). Each presentation was indexed separately. Refs, figs, tabs

  15. Employability profile of the Peruvian public accountant

    OpenAIRE

    Tarazona, Silvia; Maisch, Elena; Arias, Hernán

    2014-01-01

    The traditional perspective on the Public Accountant's professional services is running out of time and, although such services are still valuable for enterprises, the survival of the latter demands a more open and aggressive professional attitude in this field (Lebrija, 1998). Employability profiles respond to this demand by acknowledging the new abilities required of the labor force, which go beyond professional competencies. It is also these profiles which will allow coping with employment...

  16. Fernandez osteotomy of radio distal with mal united fracture

    International Nuclear Information System (INIS)

    Garcia Herrera, Alvaro; Bocanegra, Sergio; Suarez, Fabio

    2003-01-01

    We review prospectively our experience in the military hospital in Bogota, Colombia, with the opening-wedge osteotomy for the treatment of a mal united fracture of the distal end of the radius in fifty-six consecutive patients from 1990 to 2002. The indications for operation were pain predominantly in the radio-ulnar joint and functional limitation with grip strength loss. Preoperative radiographs revealed an average ulnar inclination of 14 degrees, an average ulnar variance of four millimeters, and increased dorsal tilt (colles deformity) that averaged 28 degrees. All patients had limited function. The average grip strength was a force of fifteen kilograms compared with a force of thirty-one kilograms in the contralateral hand. Postoperatively, all of the patients had substantial improvement in function, relief of pain and grip strength increased. The functional results were rated as very good in eleven patients, good in thirty-six, fair in nine

  17. Piezoresistive cantilever force-clamp system

    Energy Technology Data Exchange (ETDEWEB)

    Park, Sung-Jin; Petzold, Bryan C.; Pruitt, Beth L. [Department of Mechanical Engineering, Stanford University, Stanford, California 94305 (United States); Goodman, Miriam B. [Department of Molecular and Cellular Physiology, Stanford University, Stanford, California 94305 (United States)

    2011-04-15

    We present a microelectromechanical device-based tool, namely, a force-clamp system that sets or ''clamps'' the scaled force and can apply designed loading profiles (e.g., constant, sinusoidal) of a desired magnitude. The system implements a piezoresistive cantilever as a force sensor and the built-in capacitive sensor of a piezoelectric actuator as a displacement sensor, such that sample indentation depth can be directly calculated from the force and displacement signals. A programmable real-time controller operating at 100 kHz feedback calculates the driving voltage of the actuator. The system has two distinct modes: a force-clamp mode that controls the force applied to a sample and a displacement-clamp mode that controls the moving distance of the actuator. We demonstrate that the system has a large dynamic range (sub-nN up to tens of {mu}N force and nm up to tens of {mu}m displacement) in both air and water, and excellent dynamic response (fast response time, <2 ms and large bandwidth, 1 Hz up to 1 kHz). In addition, the system has been specifically designed to be integrated with other instruments such as a microscope with patch-clamp electronics. We demonstrate the capabilities of the system by using it to calibrate the stiffness and sensitivity of an electrostatic actuator and to measure the mechanics of a living, freely moving Caenorhabditis elegans nematode.

  18. The glacial inception as recorded in the NorthGRIP Greenland ice core: timing, structure and associated abrupt temperature changes

    Energy Technology Data Exchange (ETDEWEB)

    Landais, Amaelle [UMR CEA-CNRS, CEA Saclay, IPSL/Laboratoire des Sciences du Climat et de l' Environnement, Gif-sur -Yvette (France); Hebrew University, Institute of Earth Sciences, Givat Ram, Jerusalem (Israel); Masson-Delmotte, Valerie; Jouzel, Jean; Minster, Benedicte [UMR CEA-CNRS, CEA Saclay, IPSL/Laboratoire des Sciences du Climat et de l' Environnement, Gif-sur -Yvette (France); Raynaud, Dominique [LGGE, UMR CNRS-UJF, St Martin d' Heres (France); Johnsen, Sigfus [University of Copenhagen, Department of Geophysics, Copenhagen (Denmark); Huber, Christof; Leuenberger, Markus; Schwander, Jakob [University of Bern, Physics Institute, Bern (Switzerland)

    2006-02-01

    The mechanisms involved in the glacial inception are still poorly constrained due to a lack of high resolution and cross-dated climate records at various locations. Using air isotopic measurements in the recently drilled NorthGRIP ice core, we show that no evidence exists for stratigraphic disturbance of the climate record of the last glacial inception ({proportional_to}123-100 kyears BP) encompassing Dansgaard-Oeschger events (DO) 25, 24 and 23, even if we lack sufficient resolution to completely rule out disturbance over DO 25. We quantify the rapid surface temperature variability over DO 23 and 24 with associated warmings of 10{+-}2.5 and 16{+-}2.5 C, amplitudes which mimic those observed in full glacial conditions. We use records of {delta}{sup 18}O of O{sub 2} to propose a common timescale for the NorthGRIP and the Antarctic Vostok ice cores, with a maximum uncertainty of 2,500 years, and to examine the interhemispheric sequence of events over this period. After a synchronous North-South temperature decrease, the onset of rapid events is triggered in the North through DO 25. As for later events, DO 24 and 23 have a clear Antarctic counterpart which does not seem to be the case for the very first abrupt warming (DO 25). This information, when added to intermediate levels of CO{sub 2} and to the absence of clear ice rafting associated with DO 25, highlights the uniqueness of this first event, while DO 24 and 23 appear similar to typical full glacial DO events. (orig.)

  19. Effect of force tightening on cable tension and displacement in greater trochanter reattachment.

    Science.gov (United States)

    Canet, Fanny; Duke, Kajsa; Bourgeois, Yan; Laflamme, G-Yves; Brailovski, Vladimir; Petit, Yvan

    2011-01-01

    The purpose of this study was to evaluate cable tension during installation, and during loading similar to walking in a cable grip type greater trochanter (GT), reattachment system. A 4th generation Sawbones composite femur with osteotomised GT was reattached with four Cable-Ready® systems (Zimmer, Warsaw, IN). Cables were tightened at 3 different target installation forces (178, 356 and 534 N) and retightened once as recommended by the manufacturer. Cables tension was continuously monitored using in-situ load cells. To simulate walking, a custom frame was used to apply quasi static load on the head of a femoral stem implant (2340 N) and abductor pull (667 N) on the GT. GT displacement (gap and sliding) relative to the femur was measured using a 3D camera system. During installation, a drop in cable tension was observed when tightening subsequent cables: an average 40+12.2% and 11 ± 5.9% tension loss was measured in the first and second cable. Therefore, retightening the cables, as recommended by the manufacturer, is important. During simulated walking, the second cable additionally lost up to 12.2+3.6% of tension. No difference was observed between the GT-femur gaps measured with cables tightened at different installation forces (p=0.32). The GT sliding however was significantly greater (0.9 ± 0.3 mm) when target installation force was set to only 178 N compared to 356 N (0.2 ± 0.1 mm); pcable tightening force should be as close as possible to that recommended by the manufacturer, because reducing it compromises the stability of the GT fragment, whereas increasing it does not improve this stability, but could lead to cable breakage.

  20. Long-term outcome of muscle strength in ulnar and median nerve injury: Comparing manual muscle strength testing, grip and pinch strength dynamometers and a new intrinsic muscle strength dynamometer

    NARCIS (Netherlands)

    A.R. Schreuders (Ton); M.E. Roebroeck (Marij); J.B. Jaquet (Jean); S.E.R. Hovius (Steven); H.J. Stam (Henk)

    2004-01-01

    textabstractObjective: To compare the outcome of muscle strength with manual muscle strength testing grip and pinch strength measurements and a dynamometer which allows for measurements of the intrinsic muscles of the hand in isolation (the Rotterdam Intrinsic Hand Myometer, RIHM). Methods:

  1. Complex modulation of fingertip forces during precision grasp and lift after theta burst stimulation over the dorsal premotor cortex

    Directory of Open Access Journals (Sweden)

    Drljačić Dragana

    2017-01-01

    Full Text Available Background/Aim. Adaptive control and fingertip force synchronization of precise grasp stability during unimanual manipulation of small objects represents an illustrative example of highly fractionated movements that are foundation of fine motor control. It is assumed that this process is controlled by several motor areas of the frontal lobe, particularly applicable to the primary motor (M-1 and dorsal premotor cortex (PMd. Aiming to examine the role of PMd during fine coordination of fingertip forces we applied theta burst repetitive magnetic stimulation (TBS to disrupt neural processing in that cortical area. Methods. Using a single-blind, randomized, crossover design, 10 healthy subjects (29 ± 3.9 years received single sessions of continuous TBS (cTBS600, intermittent TBS (iTBS600, or sham stimulation, separate from one another at least one week, over the PMd region of dominant hemisphere. Precision grasp and lift were assessed by instrumented device, recording grip (G and load (L forces, during three manipulation tasks (ramp-and-hold, oscillation force producing and simple lifting tasks, with each hand separately, before and after interventions. Results. We observed the improvement of task performance related to constant error (CE in oscillation task with the dominant hand (DH after the iTBS (p = 0.009. On the contrary, the cTBS reduced variable error (VE for non-dominant hand (NH, p = 0.005. Considering force coordination we found that iTBS worsened variables for NH (G/L ratio, p = 0.017; cross-correlation of the G and L, p = 0.047; Gain, p = 0.047. Conclusion. These results demonstrate the ability of TBS to modulate fingertip forces during precision grasping and lifting, when applied over PMd. These findings support the role of PMd in human motor control and forces generation required to hold small objects stable in our hands.

  2. Memory Resilience to Alzheimer's Genetic Risk: Sex Effects in Predictor Profiles.

    Science.gov (United States)

    McDermott, Kirstie L; McFall, G Peggy; Andrews, Shea J; Anstey, Kaarin J; Dixon, Roger A

    2017-10-01

    Apolipoprotein E (APOE) ɛ4 and Clusterin (CLU) C alleles are risk factors for Alzheimer's disease (AD) and episodic memory (EM) decline. Memory resilience occurs when genetically at-risk adults perform at high and sustained levels. We investigated whether (a) memory resilience to AD genetic risk is predicted by biological and other risk markers and (b) the prediction profiles vary by sex and AD risk variant. Using a longitudinal sample of nondemented adults (n = 642, aged 53-95) we focused on memory resilience (over 9 years) to 2 AD risk variants (APOE, CLU). Growth mixture models classified resilience. Random forest analysis, stratified by sex, tested the predictive importance of 22 nongenetic risk factors from 5 domains (n = 24-112). For both sexes, younger age, higher education, stronger grip, and everyday novel cognitive activity predicted memory resilience. For women, 9 factors from functional, health, mobility, and lifestyle domains were also predictive. For men, only fewer depressive symptoms was an additional important predictor. The prediction profiles were similar for APOE and CLU. Although several factors predicted resilience in both sexes, a greater number applied only to women. Sex-specific mechanisms and intervention targets are implied. © The Author 2016. Published by Oxford University Press on behalf of The Gerontological Society of America. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  3. Sake Protein Supplementation Affects Exercise Performance and Biochemical Profiles in Power-Exercise-Trained Mice.

    Science.gov (United States)

    Chen, Yi-Ming; Lin, Che-Li; Wei, Li; Hsu, Yi-Ju; Chen, Kuan-Neng; Huang, Chi-Chang; Kao, Chin-Hsung

    2016-02-20

    Exercise and fitness training programs have attracted the public's attention in recent years. Sports nutrition supplementation is an important issue in the global sports market. In this study, we designed a power exercise training (PET) program with a mouse model based on a strength and conditional training protocol for humans. We tested the effect of supplementation with functional branched-chain amino acid (BCAA)-rich sake protein (SP) to determine whether the supplement had a synergistic effect during PET and enhanced athletic performance and resistance to fatigue. Male ICR mice were divided into three groups (n = 8 per group) for four-week treatment: sedentary controls with vehicle (SC), and PET and PET groups with SP supplementation (3.8 g/kg, PET + SP). Exercise performance was evaluated by forelimb grip strength and exhaustive swimming time as well as changes in body composition and anti-fatigue activity levels of serum lactate, ammonia, glucose, and creatine kinase (CK) after a 15-min swimming exercise. The biochemical parameters were measured at the end of the experiment. four-week PET significantly increased grip strength and exhaustive swimming time and decreased epididymal fat pad (EFP) weight and area. Levels of aspartate aminotransferase (AST), alanine aminotransferase (ALT), creatinine, and uric acid (UA) were significantly increased. PET + SP supplementation significantly decreased serum lactate, ammonia and CK levels after the 15-min swimming exercise. The resting serum levels of AST, ALT, CREA and UA were all significantly decreased with PET + SP. The PET program could increase the exercise performance and modulate the body composition of mice. PET with SP conferred better anti-fatigue activity, improved biochemical profiles, and may be an effective ergogenic aid in strength training.

  4. Thermal and hydrodynamic characteristics of forced and mixed convection flow through vertical rectangular channels

    Directory of Open Access Journals (Sweden)

    Hanafi Abdalla S.

    2008-01-01

    Full Text Available This paper presents experimental and numerical studies for the case of turbulent forced and mixed convection flow of water through narrow vertical rectangular channel. The channel is composed of two parallel plates which are heated at a uniform heat flux, whereas, the other two sides of the channel are thermally insulated. The plates are of 64 mm in width, 800 mm in height, and separated from each other at a narrow gap of 2.7 mm. The Nusselt number distribution along the flow direction normalized by the Nusselt number for the case of turbulent forced convection flow is obtained experimentally with a comparison with the numerical results obtained from a commercial computer code. The quantitative determination of the nor- malized Nusselt number with respect to the dimension-less number Z = (Gr/Re21/8Pr0.5 is presented with a comparison with previous experimental results. Qualitative results are presented for the normalized temperature and velocity profiles in the transverse direction with a comparison between the forced and mixed convection flow for both the cases of upward and downward flow directions. The effect of the axial locations and the parameter Gr/Re on the variation of the normalized temperature profiles in the transverse direction for both the regions of forced and mixed convection and for both of the upward and downward flow directions are obtained. The normalized velocity profiles in the transverse directions are also determined at different inlet velocity and heat fluxes for the previous cases. It is found that the normalized Nusselt number is greater than one in the mixed convection region for both the cases of upward and downward flow and correlated well with the dimension-less parameter Z for both of the forced and mixed convection regions. The temperature profiles increase with increasing the axial location along the flow direction or the parameter Gr/Re for both of the forced and mixed convection regions, but this increase is

  5. Is salivary cortisol moderating the relationship between salivary testosterone and hand-grip strength in healthy men?

    Science.gov (United States)

    Crewther, Blair T; Thomas, Andrew G; Stewart-Williams, Steve; Kilduff, Liam P; Cook, Christian J

    2017-03-01

    This study examined the moderating effect of cortisol (C) on the relationship between testosterone (T) and hand-grip strength (HGS) in healthy young men. Sixty-five males were monitored for salivary T, C and HGS before and 15 min after a short bout (5 × 6-s trials) of sprint cycling exercise. Sprint exercise promoted (p moderating variable. The pre-test combination of high C and low T levels favoured absolute HGS, whereas low pre-test C levels and a smaller T change were linked to larger HGS changes. These associations suggest that, in the current format, T is not necessarily anabolic to muscle strength in healthy young men. Such complexities could also explain some of the inconsistent T relationships with physical performance in lesser trained male populations.

  6. Countermovement jump height: gender and sport-specific differences in the force-time variables.

    Science.gov (United States)

    Laffaye, Guillaume; Wagner, Phillip P; Tombleson, Tom I L

    2014-04-01

    The goal of this study was to assess (a) the eccentric rate of force development, the concentric force, and selected time variables on vertical performance during countermovement jump, (b) the existence of gender differences in these variables, and (c) the sport-specific differences. The sample was composed of 189 males and 84 females, all elite athletes involved in college and professional sports (primarily football, basketball, baseball, and volleyball). The subjects performed a series of 6 countermovement jumps on a force plate (500 Hz). Average eccentric rate of force development (ECC-RFD), total time (TIME), eccentric time (ECC-T), Ratio between eccentric and total time (ECC-T:T) and average force (CON-F) were extracted from force-time curves and the vertical jumping performance, measured by impulse momentum. Results show that CON-F (r = 0.57; p differ between both sexes (p differ, showing a similar temporal structure. The best way to jump high is to increase CON-F and ECC-RFD thus minimizing the ECC-T. Principal component analysis (PCA) accounted for 76.8% of the JH variance and revealed that JH is predicted by a temporal and a force component. Furthermore, the PCA comparison made among athletes revealed sport-specific signatures: volleyball players revealed a temporal-prevailing profile, a weak-force with large ECC-T:T for basketball players and explosive and powerful profiles for football and baseball players.

  7. Visual feedback alters force control and functional activity in the visuomotor network after stroke

    Directory of Open Access Journals (Sweden)

    Derek B. Archer

    2018-01-01

    Full Text Available Modulating visual feedback may be a viable option to improve motor function after stroke, but the neurophysiological basis for this improvement is not clear. Visual gain can be manipulated by increasing or decreasing the spatial amplitude of an error signal. Here, we combined a unilateral visually guided grip force task with functional MRI to understand how changes in the gain of visual feedback alter brain activity in the chronic phase after stroke. Analyses focused on brain activation when force was produced by the most impaired hand of the stroke group as compared to the non-dominant hand of the control group. Our experiment produced three novel results. First, gain-related improvements in force control were associated with an increase in activity in many regions within the visuomotor network in both the stroke and control groups. These regions include the extrastriate visual cortex, inferior parietal lobule, ventral premotor cortex, cerebellum, and supplementary motor area. Second, the stroke group showed gain-related increases in activity in additional regions of lobules VI and VIIb of the ipsilateral cerebellum. Third, relative to the control group, the stroke group showed increased activity in the ipsilateral primary motor cortex, and activity in this region did not vary as a function of visual feedback gain. The visuomotor network, cerebellum, and ipsilateral primary motor cortex have each been targeted in rehabilitation interventions after stroke. Our observations provide new insight into the role these regions play in processing visual gain during a precisely controlled visuomotor task in the chronic phase after stroke.

  8. Reliability of force-velocity relationships during deadlift high pull.

    Science.gov (United States)

    Lu, Wei; Boyas, Sébastien; Jubeau, Marc; Rahmani, Abderrahmane

    2017-11-13

    This study aimed to evaluate the within- and between-session reliability of force, velocity and power performances and to assess the force-velocity relationship during the deadlift high pull (DHP). Nine participants performed two identical sessions of DHP with loads ranging from 30 to 70% of body mass. The force was measured by a force plate under the participants' feet. The velocity of the 'body + lifted mass' system was calculated by integrating the acceleration and the power was calculated as the product of force and velocity. The force-velocity relationships were obtained from linear regression of both mean and peak values of force and velocity. The within- and between-session reliability was evaluated by using coefficients of variation (CV) and intraclass correlation coefficients (ICC). Results showed that DHP force-velocity relationships were significantly linear (R² > 0.90, p  0.94), mean and peak velocities showed a good agreement (CV reliable and can therefore be utilised as a tool to characterise individuals' muscular profiles.

  9. Cardiovascular risk profile and frailty in a population-based study of older British men.

    Science.gov (United States)

    Ramsay, S E; Arianayagam, D S; Whincup, P H; Lennon, L T; Cryer, J; Papacosta, A O; Iliffe, S; Wannamethee, S G

    2015-04-01

    Frailty in older age is known to be associated with cardiovascular disease (CVD) risk. However, the extent to which frailty is associated with the CVD risk profile has been little studied. Our aim was to examine the associations of a range of cardiovascular risk factors with frailty and to assess whether these are independent of established CVD. Cross-sectional study of a socially representative sample of 1622 surviving men aged 71-92 examined in 2010-2012 across 24 British towns, from a prospective study initiated in 1978-1980. Frailty was defined using the Fried phenotype, including weight loss, grip strength, exhaustion, slowness and low physical activity. Among 1622 men, 303 (19%) were frail and 876 (54%) were pre-frail. Compared with non-frail, those with frailty had a higher odds of obesity (OR 2.03, 95% CI 1.38 to 2.99), high waist circumference (OR 2.30, 95% CI 1.67 to 3.17), low high-density lipoprotein-cholesterol (HDL-C) (OR 2.28, 95% CI 1.47 to 3.54) and hypertension (OR 1.79, 95% CI 1.27 to 2.54). Prevalence of these factors was also higher in those with frailty (prevalence in frail vs non-frail groups was 46% vs 31% for high waist circumference, 20% vs 11% for low HDL and 78% vs 65% for hypertension). Frail individuals had a worse cardiovascular risk profile with an increased risk of high heart rate, poor lung function (forced expiratory volume in 1 s (FEV1)), raised white cell count (WCC), poor renal function (low estimated glomerular filtration rate), low alanine transaminase and low serum sodium. Some risk factors (HDL-C, hypertension, WCC, FEV1, renal function and albumin) were also associated with being pre-frail. These associations remained when men with prevalent CVD were excluded. Frailty was associated with increased risk of a range of cardiovascular factors (including obesity, HDL-C, hypertension, heart rate, lung function, renal function) in older people; these associations were independent of established CVD. Published by the BMJ

  10. Probing surface charge potentials of clay basal planes and edges by direct force measurements.

    Science.gov (United States)

    Zhao, Hongying; Bhattacharjee, Subir; Chow, Ross; Wallace, Dean; Masliyah, Jacob H; Xu, Zhenghe

    2008-11-18

    The dispersion and gelation of clay suspensions have major impact on a number of industries, such as ceramic and composite materials processing, paper making, cement production, and consumer product formulation. To fundamentally understand controlling mechanisms of clay dispersion and gelation, it is necessary to study anisotropic surface charge properties and colloidal interactions of clay particles. In this study, a colloidal probe technique was employed to study the interaction forces between a silica probe and clay basal plane/edge surfaces. A muscovite mica was used as a representative of 2:1 phyllosilicate clay minerals. The muscovite basal plane was prepared by cleavage, while the edge surface was obtained by a microtome cutting technique. Direct force measurements demonstrated the anisotropic surface charge properties of the basal plane and edge surface. For the basal plane, the long-range forces were monotonically repulsive within pH 6-10 and the measured forces were pH-independent, thereby confirming that clay basal planes have permanent surface charge from isomorphic substitution of lattice elements. The measured interaction forces were fitted well with the classical DLVO theory. The surface potentials of muscovite basal plane derived from the measured force profiles were in good agreement with those reported in the literature. In the case of edge surfaces, the measured forces were monotonically repulsive at pH 10, decreasing with pH, and changed to be attractive at pH 5.6, strongly suggesting that the charge on the clay edge surfaces is pH-dependent. The measured force profiles could not be reasonably fitted with the classical DLVO theory, even with very small surface potential values, unless the surface roughness was considered. The surface element integration (SEI) method was used to calculate the DLVO forces to account for the surface roughness. The surface potentials of the muscovite edges were derived by fitting the measured force profiles with the

  11. A soft robotic exomusculature glove with integrated sEMG sensing for hand rehabilitation.

    Science.gov (United States)

    Delph, Michael A; Fischer, Sarah A; Gauthier, Phillip W; Luna, Carlos H Martinez; Clancy, Edward A; Fischer, Gregory S

    2013-06-01

    Stroke affects 750,000 people annually, and 80% of stroke survivors are left with weakened limbs and hands. Repetitive hand movement is often used as a rehabilitation technique in order to regain hand movement and strength. In order to facilitate this rehabilitation, a robotic glove was designed to aid in the movement and coordination of gripping exercises. This glove utilizes a cable system to open and close a patients hand. The cables are actuated by servomotors, mounted in a backpack weighing 13.2 lbs including battery power sources. The glove can be controlled in terms of finger position and grip force through switch interface, software program, or surface myoelectric (sEMG) signal. The primary control modes of the system provide: active assistance, active resistance and a preprogrammed mode. This project developed a working prototype of the rehabilitative robotic glove which actuates the fingers over a full range of motion across one degree-of-freedom, and is capable of generating a maximum 15N grip force.

  12. Identification of hydrodynamic forces around 3D surrogates using particle image velocimetry in a microfluidic channel

    Science.gov (United States)

    Afshar, Sepideh; Nath, Shubhankar; Demirci, Utkan; Hasan, Tayyaba; Scarcelli, Giuliano; Rizvi, Imran; Franco, Walfre

    2018-02-01

    Previous studies have demonstrated that flow-induced shear stress induces a motile and aggressive tumor phenotype in a microfluidic model of 3D ovarian cancer. However, the magnitude and distribution of the hydrodynamic forces that influence this biological modulation on the 3D cancer nodules are not known. We have developed a series of numerical and experimental tools to identify these forces within a 3D microchannel. In this work, we used particle image velocimetry (PIV) to find the velocity profile using fluorescent micro-spheres as surrogates and nano-particles as tracers, from which hydrodynamic forces can be derived. The fluid velocity is obtained by imaging the trajectory of a range of florescence nano-particles (500-800 μm) via confocal microscopy. Imaging was done at different horizontal planes and with a 50 μm bead as the surrogate. For an inlet current rate of 2 μl/s, the maximum velocity at the center of the channel was 51 μm/s. The velocity profile around the sphere was symmetric which is expected since the flow is dominated by viscous forces as opposed to inertial forces. The confocal PIV was successfully employed in finding the velocity profile in a microchannel with a nodule surrogate; therefore, it seems feasible to use PIV to investigate the hydrodynamic forces around 3D biological models.

  13. Wind profiler installed in Antarctica

    Science.gov (United States)

    Balsley, B. B.; Carey, J.; Woodman, R. F.; Sarango, M.; Urbina, J.; Rodriguez, R.; Ragaini, E.

    A VHF (50 MHz) wind profiler was installed in Antarctica at the Peruvian Base “Machu Picchu” on King George Island from January 21 to 26. The wind profiler will provide a first look at atmospheric dynamics over the region.The profiler—the first of its kind in Antarctica—is a National Science Foundationsponsored cooperative project of the University of Colorado, the Geophysical Institute of Peru, the University of Piura (Peru), and the Peruvian Navy. This venture was also greatly facilitated by Peru's Comision Nacional de Asuntos Antartidos and Consejo Nacional de Ciencias y Tecnologia, with additional logis tics support provided by the Argentinean Navy and the Uruguayan Air Force.

  14. Development of a New Army Standardized Physical Readiness Test: January 2012 through December 2013

    Science.gov (United States)

    2015-06-30

    children, infants, elderly, or disabled/ill persons were excluded, as were animal, in vivo, or theoretical biomechanical or engineering studies...against a single standard. This includes the current 2-mile run and push-ups. For other tests (e.g., sit ups or proposed tests such as rowing or sprints...Force PT Assessment – evaluation of (7) Predictive Fitness Tests: pushups, grip strength, grip endurance, static squat, static row , wall sit

  15. Sustained effect of resistance training on blood pressure and hand grip strength following a detraining period in elderly hypertensive women: a pilot study

    Directory of Open Access Journals (Sweden)

    Nascimento D da C

    2014-01-01

    Full Text Available Dahan da Cunha Nascimento,1,5,8 Ramires Alsamir Tibana,1,8 Franklin M Benik,2 Keila Elizabeth Fontana,3 Frederico Ribeiro Neto,8 Frederico Santos de Santana,5,8 Leopoldo Santos-Neto,4 Renato André Sousa Silva,1,5,6 Alessandro Oliveira Silva,1,7 Darlan Lopes Farias,1,7 Sandor Balsamo,4,5,8 Jonato Prestes1 1Postgraduate Program in Physical Education, Catholic University of Brasilia, Brasilia, Brazil; 2Department of Kinesiology and Sports Studies Graduate Program, Eastern Illinois University, Charleston, IL, USA; 3Faculty of Physical Education, University of Brasilia, Brasilia, Brazil; 4Graduate Program in Medical Sciences of the University of Brasilia, School of Medicine and Rheumatology Service, University Hospital of Brasilia (HUB, Brasilia, Brazil; 5Department of Physical Education, University Center Euro American University Center, Brasilia, Brazil; 6Center of Excellence in Medicine of Exercise (CEMEx, Brasilia, Brazil; 7Center University of Brasilia (UNICEUB, Brasilia, Brazil; 8Strength Training and Health Research Group (GEPEEFS, Brasilia, Brazil Introduction: Hypertension is the most prevalent modifiable risk factor with a high prevalence among older adults. Exercise is a nonpharmacological treatment shown to benefit all patients with hypertension. Objective: This study examined the effects of a 14-week moderate intensity resistance training program (RT on the maintenance of blood pressure and hand grip strength during an extended detraining period in elderly hypertensive women. Methods: Twelve hypertensive sedentary elderly women completed 14 weeks of whole body RT at a moderate perceived exertion following a detraining period of 14 weeks. Results: Following the training period, participants demonstrated an increase in absolute hand grip strength (P=0.001, relative hand grip strength (P=0.032 and a decrease of systolic (P=0.001, diastolic (P=0.008, and mean blood pressure (P=0.002 when compared to pre-exercise values. In addition, these

  16. Relativistic derivation of the ponderomotive force produced by two intense laser fields

    International Nuclear Information System (INIS)

    Stroscio, M.A.

    1985-01-01

    The ponderomotive force plays a fundamental role in the absorption of laser light on self-consistent plasma density profiles, in multiple-photon ionization, and in intense field electrodynamics. The relativistic corrections to the ponderomotive force of a transversely polarized electromagnetic wave lead to an approximately 20-percent reduction in the single particle ponderomotive force produced by a 10-γm 10 16 -W/cm 2 laser field. Recent experimental investigations are based on using two intense laser fields to produce desired lasermatter interactions. This paper presents the first derivation of the nonlinear relativistic ponderomotive force produced by two intense laser fields. The results demonstrate that relativistic ponderomotive forces are not additive

  17. Comparative study of wall-force models for the simulation of bubbly flows

    Energy Technology Data Exchange (ETDEWEB)

    Rzehak, Roland, E-mail: r.rzehak@hzdr.de [Helmholtz-Zentrum Dresden-Rossendorf (HZDR), Institute of Fluid Dynamics, POB 510119, D-01314 Dresden (Germany); Krepper, Eckhard, E-mail: E.Krepper@hzdr.de [Helmholtz-Zentrum Dresden-Rossendorf (HZDR), Institute of Fluid Dynamics, POB 510119, D-01314 Dresden (Germany); Lifante, Conxita, E-mail: Conxita.Lifante@ansys.com [ANSYS Germany GmbH, Staudenfeldweg 12, 83624 Otterfing (Germany)

    2012-12-15

    Highlights: Black-Right-Pointing-Pointer Comparison of common models for the wall force with an experimental database. Black-Right-Pointing-Pointer Identification of suitable closure for bubbly flow. Black-Right-Pointing-Pointer Enables prediction of location and height of wall peak in void fraction profiles. - Abstract: Accurate numerical prediction of void-fraction profiles in bubbly multiphase-flow relies on suitable closure models for the momentum exchange between liquid and gas phases. We here consider forces acting on the bubbles in the vicinity of a wall. A number of different models for this so-called wall-force have been proposed in the literature and are implemented in widely used CFD-codes. Simulations using a selection of these models are compared with a set of experimental data on bubbly air-water flow in round pipes of different diameter. Based on the results, recommendations on suitable closures are given.

  18. Effect of extrusion stem speed on extrusion process for a hollow aluminum profile

    International Nuclear Information System (INIS)

    Zhang, Cunsheng; Zhao, Guoqun; Chen, Zhiren; Chen, Hao; Kou, Fujun

    2012-01-01

    Highlights: ► Extrusion stem speed has significant effects on extrusion process. ► An optimum value of stem speed exists for uniform metal flow distribution. ► A higher stem speed leads to a higher required extrusion force. ► A high stem speed leads to an improved welding quality of aluminum profile. - Abstract: Extrusion stem speed is one of important process parameters during aluminum profile extrusion, which directly influences the profile quality and choice of extrusion equipments. In this paper, the extrusion process of a thin-walled hollow aluminum profile was simulated by means of the HyperXtrude commercial software. Through a serial of numerical simulation, the effects of stem speed on extrusion process, such as metal flow behavior at die exit, temperature distribution, extrusion force, and welding pressure, have been investigated. The numerical results showed that there existed an optimum value of stem speed for flow velocity distribution. With the increasing stem speed, the temperature of the extrudate and required extrusion force increased, and the welding quality of extrudate would be improved. Through comprehensive comparison and analysis, the appropriate stem speed could be determined for practical extrusion production. Thus, the research results could give effective guideline for determining initial billet and die temperature and choosing the proper extrusion press in aluminum profile industry.

  19. High quality-factor quartz tuning fork glass probe used in tapping mode atomic force microscopy for surface profile measurement

    Science.gov (United States)

    Chen, Yuan-Liu; Xu, Yanhao; Shimizu, Yuki; Matsukuma, Hiraku; Gao, Wei

    2018-06-01

    This paper presents a high quality-factor (Q-factor) quartz tuning fork (QTF) with a glass probe attached, used in frequency modulation tapping mode atomic force microscopy (AFM) for the surface profile metrology of micro and nanostructures. Unlike conventionally used QTFs, which have tungsten or platinum probes for tapping mode AFM, and suffer from a low Q-factor influenced by the relatively large mass of the probe, the glass probe, which has a lower density, increases the Q-factor of the QTF probe unit allowing it to obtain better measurement sensitivity. In addition, the process of attaching the probe to the QTF with epoxy resin, which is necessary for tapping mode AFM, is also optimized to further improve the Q-factor of the QTF glass probe. The Q-factor of the optimized QTF glass probe unit is demonstrated to be very close to that of a bare QTF without a probe attached. To verify the effectiveness and the advantages of the optimized QTF glass probe unit, the probe unit is integrated into a home-built tapping mode AFM for conducting surface profile measurements of micro and nanostructures. A blazed grating with fine tool marks of 100 nm, a microprism sheet with a vertical amplitude of 25 µm and a Fresnel lens with a steep slope of 90 degrees are used as measurement specimens. From the measurement results, it is demonstrated that the optimized QTF glass probe unit can achieve higher sensitivity as well as better stability than conventional probes in the measurement of micro and nanostructures.

  20. Human pigmentation: A side effect adapted from a primitive organism′s survival, acting through cell attachment with an affinity for the keratinocyte and for elastin: Part I

    Directory of Open Access Journals (Sweden)

    Sanju Arianayagam

    2014-01-01

    Full Text Available Pigmentation featured millions of years ago and perhaps began with an amoeba frightening off a predator with some agent such as dopamine to prevent its attachment for phagocytosis by an enemy. This paper suggests that the environmental forces of grip and stick deserve greater emphasis and that mechanical forces involved in grip and stick or release from attachment, all point to control of proteases underlying pigmentation. There is an affinity for elastin as a pathway for melanin to exit its peripheral location in the epidermis into lymphatics and play a humeral role in defense mechanisms. The hair follicle follows the epidermal-dermal pattern of behavior with an affinity for elastin, a controlling function of melanin and through the bulge, an influence of mechanical forces and control by protease inhibitors.

  1. A Force Sensorless Method for CFRP/Ti Stack Interface Detection during Robotic Orbital Drilling Operations

    Directory of Open Access Journals (Sweden)

    Qiang Fang

    2015-01-01

    Full Text Available Drilling carbon fiber reinforced plastics and titanium (CFRP/Ti stacks is one of the most important activities in aircraft assembly. It is favorable to use different drilling parameters for each layer due to their dissimilar machining properties. However, large aircraft parts with changing profiles lead to variation of thickness along the profiles, which makes it challenging to adapt the cutting parameters for different materials being drilled. This paper proposes a force sensorless method based on cutting force observer for monitoring the thrust force and identifying the drilling material during the drilling process. The cutting force observer, which is the combination of an adaptive disturbance observer and friction force model, is used to estimate the thrust force. An in-process algorithm is developed to monitor the variation of the thrust force for detecting the stack interface between the CFRP and titanium materials. Robotic orbital drilling experiments have been conducted on CFRP/Ti stacks. The estimate error of the cutting force observer was less than 13%, and the stack interface was detected in 0.25 s (or 0.05 mm before or after the tool transited it. The results show that the proposed method can successfully detect the CFRP/Ti stack interface for the cutting parameters adaptation.

  2. Motor unit firing rate patterns during voluntary muscle force generation: a simulation study

    Science.gov (United States)

    Hu, Xiaogang; Rymer, William Z.; Suresh, Nina L.

    2014-04-01

    Objective. Muscle force is generated by a combination of motor unit (MU) recruitment and changes in the discharge rate of active MUs. There have been two basic MU recruitment and firing rate paradigms reported in the literature, which describe the control of the MUs during force generation. The first (termed the reverse ‘onion skin’ profile), exhibits lower firing rates for lower threshold units, with higher firing rates occurring in higher threshold units. The second (termed the ‘onion skin’ profile), exhibits an inverse arrangement, with lower threshold units reaching higher firing rates. Approach. Using a simulation of the MU activity in a hand muscle, this study examined the force generation capacity and the variability of the muscle force magnitude at different excitation levels of the MU pool under these two different MU control paradigms. We sought to determine which rate/recruitment scheme was more efficient for force generation, and which scheme gave rise to the lowest force variability. Main results. We found that the force output of both firing patterns leads to graded force output at low excitation levels, and that the force generation capacity of the two different paradigms diverged around 50% excitation. In the reverse ‘onion skin’ pattern, at 100% excitation, the force output reached up to 88% of maximum force, whereas for the ‘onion skin’ pattern, the force output only reached up to 54% of maximum force at 100% excitation. The force variability was lower at the low to moderate force levels under the ‘onion skin’ paradigm than with the reverse ‘onion skin’ firing patterns, but this effect was reversed at high force levels. Significance. This study captures the influence of MU recruitment and firing rate organization on muscle force properties, and our results suggest that the different firing organizations can be beneficial at different levels of voluntary muscle force generation and perhaps for different tasks.

  3. Frictional forces between cohesive powder particles studied by AFM

    International Nuclear Information System (INIS)

    Jones, Robert; Pollock, Hubert M; Geldart, Derek; Verlinden-Luts, Ann

    2004-01-01

    A range of commercially important powders (hydrated alumina, limestone, titania and zeolite) and glass ballotini were attached to atomic force microscope cantilevers, and inter-particle friction forces studied in air using lateral force microscopy (LFM). The in situ calibration procedure for friction forces is described. LF images, line profiles, LF histograms, surface roughness, pull-off forces, and the load dependence of friction in the range 0-25 nN were studied for both particle-particle and particle-wall (steel) contacts. The single-particle friction results are discussed in terms of contact mechanics theory. Particle-particle contacts showed load-dependent friction, involving single asperity contacts (non-linear behaviour) or multi-asperity contacts (linear behaviour). Particle-wall contacts usually showed little load dependence and were more adhesive. The results are also related to shear stress-normal stress data (yield loci) for the same materials from bulk shear testers

  4. Force coordination in static manipulation tasks performed using standard and non-standard grasping techniques.

    Science.gov (United States)

    de Freitas, Paulo B; Jaric, Slobodan

    2009-04-01

    We evaluated coordination of the hand grip force (GF; normal component of the force acting at the hand-object contact area) and load force (LF; the tangential component) in a variety of grasping techniques and two LF directions. Thirteen participants exerted a continuous sinusoidal LF pattern against externally fixed handles applying both standard (i.e., using either the tips of the digits or the palms; the precision and palm grasps, respectively) and non-standard grasping techniques (using wrists and the dorsal finger areas; the wrist and fist grasp). We hypothesized (1) that the non-standard grasping techniques would provide deteriorated indices of force coordination when compared with the standard ones, and (2) that the nervous system would be able to adjust GF to the differences in friction coefficients of various skin areas used for grasping. However, most of the indices of force coordination remained similar across the tested grasping techniques, while the GF adjustments for the differences in friction coefficients (highest in the palm and the lowest in the fist and wrist grasp) provided inconclusive results. As hypothesized, GF relative to the skin friction was lowest in the precision grasp, but highest in the palm grasp. Therefore, we conclude that (1) the elaborate coordination of GF and LF consistently seen across the standard grasping techniques could be generalized to the non-standard ones, while (2) the ability to adjust GF using the same grasping technique to the differences in friction of various objects cannot be fully generalized to the GF adjustment when different grasps (i.e., hand segments) are used to manipulate the same object. Due to the importance of the studied phenomena for understanding both the functional and neural control aspects of manipulation, future studies should extend the current research to the transient and dynamic tasks, as well as to the general role of friction in our mechanical interactions with the environment.

  5. New force replica exchange method and protein folding pathways probed by force-clamp technique.

    Science.gov (United States)

    Kouza, Maksim; Hu, Chin-Kun; Li, Mai Suan

    2008-01-28

    We have developed a new extended replica exchange method to study thermodynamics of a system in the presence of external force. Our idea is based on the exchange between different force replicas to accelerate the equilibrium process. This new approach was applied to obtain the force-temperature phase diagram and other thermodynamical quantities of the three-domain ubiquitin. Using the C(alpha)-Go model and the Langevin dynamics, we have shown that the refolding pathways of single ubiquitin depend on which terminus is fixed. If the N end is fixed then the folding pathways are different compared to the case when both termini are free, but fixing the C terminal does not change them. Surprisingly, we have found that the anchoring terminal does not affect the pathways of individual secondary structures of three-domain ubiquitin, indicating the important role of the multidomain construction. Therefore, force-clamp experiments, in which one end of a protein is kept fixed, can probe the refolding pathways of a single free-end ubiquitin if one uses either the polyubiquitin or a single domain with the C terminus anchored. However, it is shown that anchoring one end does not affect refolding pathways of the titin domain I27, and the force-clamp spectroscopy is always capable to predict folding sequencing of this protein. We have obtained the reasonable estimate for unfolding barrier of ubiquitin, using the microscopic theory for the dependence of unfolding time on the external force. The linkage between residue Lys48 and the C terminal of ubiquitin is found to have the dramatic effect on the location of the transition state along the end-to-end distance reaction coordinate, but the multidomain construction leaves the transition state almost unchanged. We have found that the maximum force in the force-extension profile from constant velocity force pulling simulations depends on temperature nonlinearly. However, for some narrow temperature interval this dependence becomes

  6. Sparse regularization for force identification using dictionaries

    Science.gov (United States)

    Qiao, Baijie; Zhang, Xingwu; Wang, Chenxi; Zhang, Hang; Chen, Xuefeng

    2016-04-01

    The classical function expansion method based on minimizing l2-norm of the response residual employs various basis functions to represent the unknown force. Its difficulty lies in determining the optimum number of basis functions. Considering the sparsity of force in the time domain or in other basis space, we develop a general sparse regularization method based on minimizing l1-norm of the coefficient vector of basis functions. The number of basis functions is adaptively determined by minimizing the number of nonzero components in the coefficient vector during the sparse regularization process. First, according to the profile of the unknown force, the dictionary composed of basis functions is determined. Second, a sparsity convex optimization model for force identification is constructed. Third, given the transfer function and the operational response, Sparse reconstruction by separable approximation (SpaRSA) is developed to solve the sparse regularization problem of force identification. Finally, experiments including identification of impact and harmonic forces are conducted on a cantilever thin plate structure to illustrate the effectiveness and applicability of SpaRSA. Besides the Dirac dictionary, other three sparse dictionaries including Db6 wavelets, Sym4 wavelets and cubic B-spline functions can also accurately identify both the single and double impact forces from highly noisy responses in a sparse representation frame. The discrete cosine functions can also successfully reconstruct the harmonic forces including the sinusoidal, square and triangular forces. Conversely, the traditional Tikhonov regularization method with the L-curve criterion fails to identify both the impact and harmonic forces in these cases.

  7. In the grip of the python: conflicts at the university-industry interface.

    Science.gov (United States)

    Healy, David

    2003-01-01

    When the University of Toronto withdrew a contract it held with me in December 2000, it initiated a sequence of events that led to a public letter to the University from senior figures in the world psychopharmacology community protesting against the infringement of academic freedom involved and a first ever legal action, undertake by this author, seeking redress for a violation of academic freedom. The issues of academic freedom surrounding this case have been intertwined with a debate about the possibility that the selective serotonin reuptake inhibitor (SSRI) group of antidepressants have the potential to trigger suicidality in a subgroup of patients. Whether the SSRIs do trigger suicidality or not, exploration of this issue has given rise to a number of worrying sets of observations. First, in my view, there is evidence that pharmaceutical companies have miscoded raw data on suicidal acts and suicidal ideation. Second, this author also maintains that there is a growing body of examples of ghostwriting of articles in the therapeutics domain. Many of the tensions evident in this case, therefore, can be linked to company abilities to keep clinical trial data out of the public domain--this is the point at which the pharmaceutical python gets a grip on academia.

  8. TEMPS-A[p] temperament profile related to professional choice: A study in 1548 applicants to become a cadet officer in the Italian air force.

    Science.gov (United States)

    Maremmani, Icro; Dell'Osso, Liliana; Rovai, Luca; Pacini, Matteo; Arduino, Gualberto; Montagnari, Antonio; Abbenante, Domenico; Maremmani, Angelo G I; Giulio, Perugi; Akiskal, Kareen; Akiskal, Hagop

    2010-08-01

    Temperaments have been described with respect to their adaptive roles. Thus, depressive traits seem to increase sensitivity to suffering, cyclothymic traits appear relevant to creativity, and hyperthymic traits have been implicated in territoriality and leadership and more generally in active pursuits. The temperaments of 1548 candidates applying to become a cadet officer in the Italian air force, who had taken the 2005 entrance examination, were compared with deviant and non-deviant peers. At a psychological level, we also compared those who had applied to become a cadet officer with other applicants who had failed in a previous entrance examination and with applicants who had passed or failed to pass the specific psychological entrance examination. Applicants who took the entrance examination are more hyperthymic than their peers, regardless of any concurrent psychosocial deviance (i.e. drug addiction). The specificity of this correlation is confirmed by the fact that applicants who made a second attempt to pass the entrance examination after an initial failure were more hyperthymic than first-time applicants. Similarly, success in specific psychological admission tests is related to the same temperamental profiles, since those who prove to be psychologically fit are more hyperthymic. The inverse relationship emerges from an examination of other temperamental scales, which are better represented in controls (non-applicants), or other applicants making their first attempt at admission, or those who were excluded due to psychological flaws. In the present study, extremely high scores on the hyperthymic scale combined with extremely low ones in the cyclothymic scale seem to correspond to the specific temperament profile and to the highest likelihood of success in those applying to become a cadet officer in the Italian air force. Copyright 2010 Elsevier B.V. All rights reserved.

  9. Tools for Manipulation and Characterisation of Nanostructures

    DEFF Research Database (Denmark)

    Mølhave, Kristian; Bøggild, Peter

    grippers, which were then successfully used for pick-and-place manipulation of silicon nanowires. For increased gripping force and control over the manipulation process, microfabricated grippers with integrated force-feedback were also demonstrated. Environmental electron beam deposition (EEBD...... components that are some 10000 times smaller....

  10. Comparative cervical profiles of adult and under-18 front-row rugby players: implications for playing policy

    Science.gov (United States)

    Hamilton, D F; Gatherer, D; Robson, J; Graham, N; Rennie, N; MacLean, J G B; Simpson, A H R W

    2014-01-01

    Objective To compare the cervical isometric strength, fatigue endurance and range of motion of adult and under-18 age-grade front-row rugby players to inform the development of a safe age group policy with particular reference to scrummaging. Design Cross-sectional cohort study. Setting ‘Field testing’ at Murrayfield stadium. Participants 30 high-performance under-18 players and 22 adult front-row rugby players. Outcome measures Isometric neck strength, height, weight and grip strength. Results Youth players demonstrated the same height and grip strength as the adult players; however, the adults were significantly heavier and demonstrated substantially greater isometric strength (prugby players demonstrate the same peripheral strength as their adult counterparts on grip testing, the adults demonstrate significantly greater cervical strength. If older youths and adults are to play together, such findings have to be noted in the development of age group policies with particular reference to the scrum. PMID:24797427

  11. Disease Vector Ecology Profile: Ecuador

    Science.gov (United States)

    1998-12-01

    years occurred in Peru in the northern departments bordering Ecuador in 1992-1994. Sylvatic plague is endemic in the southern provinces of Loja and... Ecuador ) Micrurus bocourti (Pacific lowlands of western Ecuador ) Micrurus catamayensis (Catamayo Valley, Loja Province) Micrurus dumerilii spp...Disease Vector Ecology Profile Ecuador -~· ""’ -.. ~ """ Defense Pest Management Information Analysis Center’ Armed Forces Pest Management

  12. Sake Protein Supplementation Affects Exercise Performance and Biochemical Profiles in Power-Exercise-Trained Mice

    Directory of Open Access Journals (Sweden)

    Yi-Ming Chen

    2016-02-01

    Full Text Available Exercise and fitness training programs have attracted the public’s attention in recent years. Sports nutrition supplementation is an important issue in the global sports market. Purpose: In this study, we designed a power exercise training (PET program with a mouse model based on a strength and conditional training protocol for humans. We tested the effect of supplementation with functional branched-chain amino acid (BCAA-rich sake protein (SP to determine whether the supplement had a synergistic effect during PET and enhanced athletic performance and resistance to fatigue. Methods: Male ICR mice were divided into three groups (n = 8 per group for four-week treatment: sedentary controls with vehicle (SC, and PET and PET groups with SP supplementation (3.8 g/kg, PET + SP. Exercise performance was evaluated by forelimb grip strength and exhaustive swimming time as well as changes in body composition and anti-fatigue activity levels of serum lactate, ammonia, glucose, and creatine kinase (CK after a 15-min swimming exercise. The biochemical parameters were measured at the end of the experiment. Results: four-week PET significantly increased grip strength and exhaustive swimming time and decreased epididymal fat pad (EFP weight and area. Levels of aspartate aminotransferase (AST, alanine aminotransferase (ALT, creatinine, and uric acid (UA were significantly increased. PET + SP supplementation significantly decreased serum lactate, ammonia and CK levels after the 15-min swimming exercise. The resting serum levels of AST, ALT, CREA and UA were all significantly decreased with PET + SP. Conclusion: The PET program could increase the exercise performance and modulate the body composition of mice. PET with SP conferred better anti-fatigue activity, improved biochemical profiles, and may be an effective ergogenic aid in strength training.

  13. A Study of the Confinement Induced Sponge to Lamellar Phase Transformation by Direct Force Measurement

    International Nuclear Information System (INIS)

    Antelmi, David

    1996-10-01

    The interactions between two macroscopic walls immersed in an isotropic symmetric sponge phase (L_3) at different volume fractions, Φ, were studied with a surface force apparatus. The purpose of these experiments was to investigate the behaviour of the sponge phase when confined between two smooth rigid surfaces. Particular attention was given to investigating this behaviour as the bulk transition to the lamellar phase (L_α) was approached. At temperatures far from the L_3/L_α bulk transition temperature, the force-distance profile showed weak oscillations with a periodicity approximately equal to twice the characteristic length, ξ, measured for the sponge phase from small angle x-ray scattering. Furthermore, the oscillations were superimposed on an exponential attractive background that decayed with an order parameter correlation length of 2-3 times ξ The attractive background was explained by the enhancement of the sponge order in the vicinity of the rigid walls. The structural oscillations observed in the force-distance profile, although not completely understood, were discussed in terms of the packing of sponge cells (cell size ξ). The significance of the observed periodicity (2ξ) may indicate the importance of the symmetric nature of the sponge phase. By moving pairs of cells in response to an applied strain, the symmetry of the sponge structure is protected. As the temperature increased towards the L_3/L_α bulk transition temperature, an abrupt change in the force-distance profile was observed at a threshold separation labelled D*_i_n. A different force regime was observed for separations below D*_i_n which oscillated with a periodicity that was twice the reticular spacing, d, for a L_α phase of similar Φ. The force oscillations were superimposed on an attractive background that was almost linear. These observations were consistent with a first order phase transition from the sponge phase to the lamellar phase, induced by the confinement, where the

  14. Coenzyme Q10 Status as a Determinant of Muscular Strength in Two Independent Cohorts.

    Directory of Open Access Journals (Sweden)

    Alexandra Fischer

    Full Text Available Aging is associated with sarcopenia, which is a loss of skeletal muscle mass and function. Coenzyme Q10 (CoQ10 is involved in several important functions that are related to bioenergetics and protection against oxidative damage; however, the role of CoQ10 as a determinant of muscular strength is not well documented. The aim of the present study was to evaluate the determinants of muscular strength by examining hand grip force in relation to CoQ10 status, gender, age and body mass index (BMI in two independent cohorts (n = 334, n = 967. Furthermore, peak flow as a function of respiratory muscle force was assessed. Spearman's correlation revealed a significant positive association between CoQ10/cholesterol level and hand grip in the basic study population (p<0.01 as well as in the validation population (p<0.001. In the latter, we also found a negative correlation with the CoQ10 redox state (p<0.01, which represents a lower percentage of the reduced form of CoQ10 (ubiquinol in subjects who exhibit a lower muscular strength. Furthermore, the age of the subjects showed a negative correlation with hand grip (p<0.001, whereas BMI was positively correlated with hand grip (p<0.01, although only in the normal weight subgroup (BMI <25 kg/m2. Analysis of the covariance (ANCOVA with hand grip as the dependent variable revealed CoQ10/cholesterol as a determinant of muscular strength and gender as the strongest effector of hand grip. In conclusion, our data suggest that both a low CoQ10/cholesterol level and a low percentage of the reduced form of CoQ10 could be an indicator of an increased risk of sarcopenia in humans due to their negative associations to upper body muscle strength, peak flow and muscle mass.

  15. Radiation forcing by the atmospheric aerosols in the nocturnal boundary layer

    Science.gov (United States)

    Singh, D. K.; Ponnulakshami, V. K.; Mukund, V.; Subramanian, G.; Sreenivas, K. R.

    2013-05-01

    We have conducted experimental and theoretical studies on the radiation forcing due to suspended aerosols in the nocturnal boundary layer. We present radiative, conductive and convective equilibrium profile for different bottom boundaries where calculated Rayleigh number is higher than the critical Rayleigh number in laboratory conditions. The temperature profile can be fitted using an exponential distribution of aerosols concentration field. We also present the vertical temperature profiles in a nocturnal boundary in the presence of fog in the field. Our results show that during the presence of fog in the atmosphere, the ground temperature is greater than the dew-point temperature. The temperature profiles before and after the formation of fog are also observed to be different.

  16. Molecular dynamic simulation of Ar-Kr mixture across a rough walled nanochannel: Velocity and temperature profiles

    International Nuclear Information System (INIS)

    Pooja,; Ahluwalia, P. K.; Pathania, Y.

    2015-01-01

    This paper presents the results from a molecular dynamics simulation of mixture of argon and krypton in the Poiseuille flow across a rough walled nanochannel. The roughness effect on liquid nanoflows has recently drawn attention The computational software used for carrying out the molecular dynamics simulations is LAMMPS. The fluid flow takes place between two parallel plates and is bounded by horizontal rough walls in one direction and periodic boundary conditions are imposed in the other two directions. Each fluid atom interacts with other fluid atoms and wall atoms through Leenard-Jones (LJ) potential with a cut off distance of 5.0. To derive the flow a constant force is applied whose value is varied from 0.1 to 0.3 and velocity profiles and temperature profiles are noted for these values of forces. The velocity profile and temperature profiles are also looked at different channel widths of nanochannel and at different densities of mixture. The velocity profile and temperature profile of rough walled nanochannel are compared with that of smooth walled nanochannel and it is concluded that mean velocity increases with increase in channel width, force applied and decrease in density also with introduction of roughness in the walls of nanochannel mean velocity again increases and results also agree with the analytical solution of a Poiseuille flow

  17. Measurement of the traction force of biological cells by digital holography

    Science.gov (United States)

    Yu, Xiao; Cross, Michael; Liu, Changgeng; Clark, David C.; Haynie, Donald T.; Kim, Myung K.

    2011-01-01

    The traction force produced by biological cells has been visualized as distortions in flexible substrata. We have utilized quantitative phase microscopy by digital holography (DH-QPM) to study the wrinkling of a silicone rubber film by motile fibroblasts. Surface deformation and the cellular traction force have been measured from phase profiles in a direct and straightforward manner. DH-QPM is shown to provide highly efficient and versatile means for quantitatively analyzing cellular motility. PMID:22254175

  18. Model for radial gas fraction profiles in vertical pipe flow

    International Nuclear Information System (INIS)

    Lucas, D.; Krepper, E.; Prasser, H.M.

    2001-01-01

    A one-dimensional model is presented, which predicts the radial volume fraction profiles from a given bubble size distribution. It bases on the assumption of an equilibrium of the forces acting on a bubble perpendicularly to the flow path (non drag forces). For the prediction of the flow pattern this model could be used within an procedure together with appropriate models for local bubble coalescence and break-up. (orig.)

  19. Surface texture generation during cylindrical milling in the aspect of cutting force variations

    International Nuclear Information System (INIS)

    Wojciechowski, S; Twardowski, P; Pelic, M

    2014-01-01

    The work presented here concentrates on surface texture analysis, after cylindrical milling of hardened steel. Cutting force variations occurring in the machining process have direct influence on the cutter displacements and thus on the generated surface texture. Therefore, in these experiments, the influence of active number of teeth (z c ) on the cutting force variations was investigated. Cutting forces and cutter displacements were measured during machining process (online) using, namely piezoelectric force dynamometer and 3D laser vibrometer. Surface roughness parameters were measured using stylus surface profiler. The surface roughness model including cutting parameters (f z , D) and cutting force variations was also developed. The research revealed that in cylindrical milling process, cutting force variations have immediate influence on surface texture generation

  20. Direct transverse load profile determination using the polarization-dependent loss spectral response of a chirped fiber Bragg grating.

    Science.gov (United States)

    Descamps, Frédéric; Bette, Sébastien; Kinet, Damien; Caucheteur, Christophe

    2016-06-01

    The determination of stress profiles created by transverse loads was proved to be important in different domains, such as structural health monitoring and biomechanics, and, more specifically, in the prostheses domain. In this paper, we report an original method to estimate the transverse load profile from the polarization-dependent loss (PDL) spectrum of a chirped fiber Bragg grating (CFBG). This method makes use of the relationship between the integration of the PDL of a CFBG, and the force profile has the advantage of not requiring any iterative method to estimate the transverse load profile. The relationship linking the integration of the PDL and the force profile is demonstrated using an analytical approximation of the transmission spectrum of CFBGs. The validity of this method for the determination of non-uniform load profiles is then shown using a numerical analysis. An experimental demonstration is finally reported using a 48 mm-long CFBG subject to different step transverse load profiles.

  1. A comparative study of lipid profile and autonomic functions in vegetarian and non-vegetarian postmenopausal women

    Directory of Open Access Journals (Sweden)

    Arunima Chaudhuri

    2013-01-01

    Full Text Available Background: The prevalence of dyslipedaemia, autonomic dysfunction leading to cardiovascular diseases, increases with menopause and an ageing population. Autonomic dysfunction as measured by lower heart rate variability is an established risk factor for cardiac death. Diet and nutrition have been extensively investigated as risk factors for major cardiovascular diseases and are also linked to other cardiovascular risk factors. Objectives: To compare lipid profile and autonomic functions of postmenopausal women on vegetarian and non- vegetarian diet. Materials and Methods: 120 Postmenopausal women (menopausal duration and age-matched without any gross systemic disease from an Industrial population were selected. Sixty women were on vegetarian diet and 60 on non-vegetarian diet. BMI and waist/hip ratios were calculated, lipid profile was analyzed, and autonomic function tests were carried out. A comparison was done between the two groups using Students t test. Pearson′s correlation coefficient was calculated between the independent variable (lipid profile parameters and the dependent variables (deep breath test, valsalva ratio, 30:15 ratio, OTT, IHG, CPT to understand the effect of lipid profile on autonomic control of heart. Results : Significant increases in total cholesterol, triglyceride, LDL, cholesterol/HDL ratio were noticed in women on non-vegetarian diet. Results of autonomic function tests, i.e. valsalva ratio, deep breath test, 30: 15R-R intervals ratio, isometric hand grip test, cold pressor test, and orthostatic tolerance test were significantly worsened in postmenopausal women on non-vegetarian diet. Conclusion: Dietary factors may be an important cause of alteration of lipid metabolism. Increased cholesterol decreases heart rate variability and increased LDL cholesterol decreases baroreceptor sensitivity thereby worsening autonomic functions in postmenopausal women.

  2. Surface EMG and intra-socket force measurement to control a prosthetic device

    Science.gov (United States)

    Sanford, Joe; Patterson, Rita; Popa, Dan

    2015-06-01

    Surface electromyography (SEMG) has been shown to be a robust and reliable interaction method allowing for basic control of powered prosthetic devices. Research has shown a marked decrease in EMG-classification efficiency throughout activities of daily life due to socket shift and movement and fatigue as well as changes in degree of fit of the socket throughout the subject's lifetime. Users with the most severe levels of amputation require the most complex devices with the greatest number of degrees of freedom. Controlling complex dexterous devices with limited available inputs requires the addition of sensing and interaction modalities. However, the larger the amputation severity, the fewer viable SEMG sites are available as control inputs. Previous work reported the use of intra-socket pressure, as measured during wrist flexion and extension, and has shown that it is possible to control a powered prosthetic device with pressure sensors. In this paper, we present data correlations of SEMG data with intra-socket pressure data. Surface EMG sensors and force sensors were housed within a simulated prosthetic cuff fit to a healthy-limbed subject. EMG and intra-socket force data was collected from inside the cuff as a subject performed pre-defined grip motions with their dominant hand. Data fusion algorithms were explored and allowed a subject to use both intra-socket pressure and SEMG data as control inputs for a powered prosthetic device. This additional input modality allows for an improvement in input classification as well as information regarding socket fit through out activities of daily life.

  3. Free energy simulations with the AMOEBA polarizable force field and metadynamics on GPU platform.

    Science.gov (United States)

    Peng, Xiangda; Zhang, Yuebin; Chu, Huiying; Li, Guohui

    2016-03-05

    The free energy calculation library PLUMED has been incorporated into the OpenMM simulation toolkit, with the purpose to perform enhanced sampling MD simulations using the AMOEBA polarizable force field on GPU platform. Two examples, (I) the free energy profile of water pair separation (II) alanine dipeptide dihedral angle free energy surface in explicit solvent, are provided here to demonstrate the accuracy and efficiency of our implementation. The converged free energy profiles could be obtained within an affordable MD simulation time when the AMOEBA polarizable force field is employed. Moreover, the free energy surfaces estimated using the AMOEBA polarizable force field are in agreement with those calculated from experimental data and ab initio methods. Hence, the implementation in this work is reliable and would be utilized to study more complicated biological phenomena in both an accurate and efficient way. © 2015 Wiley Periodicals, Inc. © 2015 Wiley Periodicals, Inc.

  4. Force-velocity properties' contribution to bilateral deficit during ballistic push-off.

    Science.gov (United States)

    Samozino, Pierre; Rejc, Enrico; di Prampero, Pietro Enrico; Belli, Alain; Morin, Jean-Benoît

    2014-01-01

    The objective of this study is to quantify the contribution of the force-velocity (F-v) properties to bilateral force deficit (BLD) in ballistic lower limb push-off and to relate it to individual F-v mechanical properties of the lower limbs. The F-v relation was individually assessed from mechanical measurements for 14 subjects during maximal ballistic lower limb push-offs; its contribution to BLD was then investigated using a theoretical macroscopic approach, considering both the mechanical constraints of movement dynamics and the maximal external capabilities of the lower limb neuromuscular system. During ballistic lower limb push-off, the maximum force each lower limb can produce was lower during bilateral than unilateral actions, thus leading to a BLD of 36.7% ± 5.7%. The decrease in force due to the F-v mechanical properties amounted to 19.9% ± 3.6% of the force developed during BL push-offs, which represents a nonneural contribution to BLD of 43.5% ± 9.1%. This contribution to BLD that cannot be attributed to changes in neural features was negatively correlated to the maximum unloaded extension velocity of the lower limb (r = -0.977, P push-off, BLD is due to both neural alterations and F-v mechanical properties, the latter being associated with the change in movement velocity between bilateral and unilateral actions. The level of the contribution of the F-v properties depends on the individual F-v mechanical profile of the entire lower limb neuromuscular system: the more the F-v profile is oriented toward velocity capabilities, the lower the loss of force from unilateral to bilateral push-offs due to changes in movement velocity.

  5. Coherent Multimodal Sensory Information Allows Switching between Gravitoinertial Contexts.

    Science.gov (United States)

    Barbiero, Marie; Rousseau, Célia; Papaxanthis, Charalambos; White, Olivier

    2017-01-01

    Whether the central nervous system is capable to switch between contexts critically depends on experimental details. Motor control studies regularly adopt robotic devices to perturb the dynamics of a certain task. Other approaches investigate motor control by altering the gravitoinertial context itself as in parabolic flights and human centrifuges. In contrast to conventional robotic experiments, where only the hand is perturbed, these gravitoinertial or immersive settings coherently plunge participants into new environments. However, radically different they are, perfect adaptation of motor responses are commonly reported. In object manipulation tasks, this translates into a good matching of the grasping force or grip force to the destabilizing load force. One possible bias in these protocols is the predictability of the forthcoming dynamics. Here we test whether the successful switching and adaptation processes observed in immersive environments are a consequence of the fact that participants can predict the perturbation schedule. We used a short arm human centrifuge to decouple the effects of space and time on the dynamics of an object manipulation task by adding an unnatural explicit position-dependent force. We created different dynamical contexts by asking 20 participants to move the object at three different paces. These contextual sessions were interleaved such that we could simulate concurrent learning. We assessed adaptation by measuring how grip force was adjusted to this unnatural load force. We found that the motor system can switch between new unusual dynamical contexts, as reported by surprisingly well-adjusted grip forces, and that this capacity is not a mere consequence of the ability to predict the time course of the upcoming dynamics. We posit that a coherent flow of multimodal sensory information born in a homogeneous milieu allows switching between dynamical contexts.

  6. Coherent Multimodal Sensory Information Allows Switching between Gravitoinertial Contexts

    Directory of Open Access Journals (Sweden)

    Marie Barbiero

    2017-05-01

    Full Text Available Whether the central nervous system is capable to switch between contexts critically depends on experimental details. Motor control studies regularly adopt robotic devices to perturb the dynamics of a certain task. Other approaches investigate motor control by altering the gravitoinertial context itself as in parabolic flights and human centrifuges. In contrast to conventional robotic experiments, where only the hand is perturbed, these gravitoinertial or immersive settings coherently plunge participants into new environments. However, radically different they are, perfect adaptation of motor responses are commonly reported. In object manipulation tasks, this translates into a good matching of the grasping force or grip force to the destabilizing load force. One possible bias in these protocols is the predictability of the forthcoming dynamics. Here we test whether the successful switching and adaptation processes observed in immersive environments are a consequence of the fact that participants can predict the perturbation schedule. We used a short arm human centrifuge to decouple the effects of space and time on the dynamics of an object manipulation task by adding an unnatural explicit position-dependent force. We created different dynamical contexts by asking 20 participants to move the object at three different paces. These contextual sessions were interleaved such that we could simulate concurrent learning. We assessed adaptation by measuring how grip force was adjusted to this unnatural load force. We found that the motor system can switch between new unusual dynamical contexts, as reported by surprisingly well-adjusted grip forces, and that this capacity is not a mere consequence of the ability to predict the time course of the upcoming dynamics. We posit that a coherent flow of multimodal sensory information born in a homogeneous milieu allows switching between dynamical contexts.

  7. Nano-mechanics of Tunable Adhesion using Non Covalent Forces

    Energy Technology Data Exchange (ETDEWEB)

    Kenneth Liechti

    2012-09-08

    The objective of this program was to examine, via experiment and atomistic and continuum analysis, coordinated noncovalent bonding over a range of length scales with a view to obtaining modulated, patterned and reversible bonding at the molecular level. The first step in this project was to develop processes for depositing self-assembled monolayers (SAMs) bearing carboxylic acid and amine moieties on Si (111) surfaces and probe tips of an interfacial force microscope (IFM). This allowed the adhesive portion of the interactions between functionalized surfaces to be fully captured in the force-displacement response (force profiles) that are measured by the IFM. The interactionswere extracted in the form of traction-separation laws using combined molecular and continuum stress analyses. In this approach, the results of molecular dynamics analyses of SAMs subjected to simple stress states are used to inform continuum models of their stress-strain behavior. Continuum analyses of the IFM experiment were then conducted, which incorporate the stress-strain behavior of the SAMs and traction-separation relations that represent the interactions between the tip and functionalized Si surface. Agreement between predicted and measured force profiles was taken to imply that the traction-separation relations have been properly extracted. Scale up to larger contact areas was considered by forming Si/SAM/Si sandwiches and then separating them via fracture experiments. The mode 1 traction-separation relations have been extracted using fracture mechanics concepts under mode 1 and mixed-mode conditions. Interesting differences were noted between the three sets of traction-separation relations.

  8. A dinamometria manual e seu uso na avaliação nutricional Hand grip strength test and its use in nutritional assessment

    Directory of Open Access Journals (Sweden)

    Michael Maia Schlüssel

    2008-04-01

    Full Text Available Esta revisão de literatura aborda aspectos metodológicos e fisiológicos da dinamometria manual. A dinamometria manual é um teste funcional do músculo esquelético que vem recebendo uma crescente atenção de clínicos e pesquisadores da área de saúde nos últimos anos. Recentemente, tem merecido atenção como indicador do estado nutricional, particularmente para pacientes internados. Dentre os principais fatores que influenciam esta medida, destacam-se o sexo, a idade, a estatura, a massa corporal e a mão dominante dos indivíduos. Os resultados desta revisão demonstram ainda que diversos outros fatores, relacionados ao protocolo de aferição, como a posição do indivíduo, o tipo de instrumento utilizado, o número de aferições realizadas, o intervalo de descanso entre as aferições, a presença de estímulo verbal e de um pré-teste, também podem influenciar os valores alcançados por um indivíduo em uma avaliação da dinamometria manual. Dessa forma, é importante que um protocolo de aferição padronizado seja desenvolvido, para que se obtenham medidas válidas de dinamometria manual. Ainda são escassos os estudos que propõem valores de referência para a dinamometria manual e a literatura ainda se ressente de valores de referência baseados em dados obtidos a partir de amostras de base populacional.This paper reviews the methodological and physiological aspects of hand grip strength measurement. Hand grip strength assesses skeletal muscle function and has received increasing attention from physicians and health-related researchers in the last years. Recently, it has deserved particular attention as an indicator of nutritional status, particularly in hospitalized patients. Sex, age, height, body mass and the dominant hand of the subjects are the main factors that influence the measure. The results of this review demonstrate that many other factors associated with the assessment protocol, such as the position of the

  9. The predictive value of extensor grip test for the effectiveness of treatment for tennis elbow

    International Nuclear Information System (INIS)

    Zehtab, Mohammad J.; Mirghasemi, A.; Majlesara, A.; Siavashi, B.; Tajik, P.

    2008-01-01

    Objective was to compare the effectiveness of 5 different modalities and determine the usefulness of recently proposed extensor grip test (EGT) in predicting the response to treatment. In a randomized controlled clinical trial, 92 of 98 tennis elbow patients in Sina Hospital Tehran, Iran between 2006 and 2007 fulfilled the trial entry criteria. Among these patients 56 (60.9%) had positive EGT results, were randomly allocated to 5 treatment groups: brace, physiotherapy, brace plus physiotherapy, injection and injection plus physiotherapy. Patients with a positive EGT result had better response to treatments. Among them, injection plus physiotherapy was the most successful, then brace plus physiotherapy was the worst treatment modality. Response to treatment was comparable in all groups between EGT positive and negative patients except bracing, in which positive EGT was correlated with dramatic response to treatment. In all patients, injection plus physiotherapy and the brace plus physiotherapy is recommended, but in EGT negatives, bracing seems to be of no use. Injection alone is not recommended in either group. (author)

  10. Simulation study of a single-grip harvester in thinning from below and thinning from above

    Energy Technology Data Exchange (ETDEWEB)

    Eliasson, Lars [Swedish Univ. of Agricultural Sciences, Umeaa (Sweden). Dept. of Silviculture; Lageson, Haakan [Forest Owner' s Ass. of Norrbotten, Boden (Sweden)

    1999-07-01

    The time consumption and productivity of a single-grip harvester were studied, using a simulation model, when thinning from below and above in eight randomly selected stands. The model estimated the time required for each work element, given machine and tree positions, and tree size. A 2 x 5 factorial design was used with factors thinning type [from below (T{sub b}) and above (T{sub a})] and tree size. Trees were subjectively selected for harvest according to thinning type. Total basal area removal was 30% plot{sup -1}. Approximately 50% more trees were harvested in T{sub b} than in T{sub a}. Time consumption tree{sup -1} was higher for T{sub a} than T{sub b}. Time consumption for machine and boom movements decreased with increasing number of harvested trees, and time for felling and processing of trees increased with harvested mean stem volume. Harvester productivity was 36% higher for T{sub a}, since the increase in harvested mean stem volume was higher than the increase in time consumption tree{sup -1}.

  11. Force Trends and Pulsatility for Catheter Contact Identification in Intracardiac Electrograms during Arrhythmia Ablation.

    Science.gov (United States)

    Rivas-Lalaleo, David; Muñoz-Romero, Sergio; Huerta, Mónica; Erazo-Rodas, Mayra; Sánchez-Muñoz, Juan José; Rojo-Álvarez, José Luis; García-Alberola, Arcadi

    2018-05-02

    The intracardiac electrical activation maps are commonly used as a guide in the ablation of cardiac arrhythmias. The use of catheters with force sensors has been proposed in order to know if the electrode is in contact with the tissue during the registration of intracardiac electrograms (EGM). Although threshold criteria on force signals are often used to determine the catheter contact, this may be a limited criterion due to the complexity of the heart dynamics and cardiac vorticity. The present paper is devoted to determining the criteria and force signal profiles that guarantee the contact of the electrode with the tissue. In this study, we analyzed 1391 force signals and their associated EGM recorded during 2 and 8 s, respectively, in 17 patients (82 ± 60 points per patient). We aimed to establish a contact pattern by first visually examining and classifying the signals, according to their likely-contact joint profile and following the suggestions from experts in the doubtful cases. First, we used Principal Component Analysis to scrutinize the force signal dynamics by analyzing the main eigen-directions, first globally and then grouped according to the certainty of their tissue-catheter contact. Second, we used two different linear classifiers (Fisher discriminant and support vector machines) to identify the most relevant components of the previous signal models. We obtained three main types of eigenvectors, namely, pulsatile relevant, non-pulsatile relevant, and irrelevant components. The classifiers reached a moderate to sufficient discrimination capacity (areas under the curve between 0.84 and 0.95 depending on the contact certainty and on the classifier), which allowed us to analyze the relevant properties in the force signals. We conclude that the catheter-tissue contact profiles in force recordings are complex and do not depend only on the signal intensity being above a threshold at a single time instant, but also on time pulsatility and trends. These

  12. Profile distortion by beam space-charge in Ionization Profile Monitors

    CERN Document Server

    Vilsmeier, D; Wettig, T

    Measuring the transverse beam size in the Large Hadron Collider by using Ionization Profile Monitors is a difficult task for energies above injection during the energy ramp from 450 GeV to 6.5TeV. The beam size decreases from around 1mm to 200um and the brightness of the beam is high enough to destroy the structure of any form of interacting matter. While the electron trajectories are confined by an external electro-magnetic field which forces the electrons accordingly on helix paths with certain gyroradii, this gyration is heavily increased under the influence of the electric field of the beam. Smaller beam sizes, which go hand in hand with increased bunch electric fields, lead to larger gyroradii of the ionized electrons, which results in strongly distorted profiles. In addition, this distortion becomes more visible for smaller beam sizes as the extent of gyration grows compared to the actual beam size. Depending on the initial momentum distribution of the electrons, emerging from the ionization process wit...

  13. Functional studies in 79-year-olds. II. Upper extremity function.

    Science.gov (United States)

    Lundgren-Lindquist, B; Sperling, L

    1983-01-01

    As part of the Gerontological and Geriatric Population Study of 79-year-old people in Göteborg, a representative subsample comprising 112 women and 93 men took part in a study of upper extremity function. Thirty-eight per cent of the women and 37% of the men had disorders in the upper extremities. The investigation included tests of co-ordination, static strength in the key-grip and the transversal volar grip, power capacity in opening jars and a bottle, basal movements in the upper extremities in personal hygiene and dressing activities, function in the kitchen e.g. reaching shelves, manual tasks including tests of pronation and supination of the forearm. In the key-grip as well as in the transversal volar grip men showed a generally larger decrease in strength with age than women compared to 70-year-olds in a previous population study. Significant correlations were found between strength in the key-grip and the performance time in the test of co-ordination. Women produced about 66% of the muscular force of the men when opening jars. Significant correlations were found between strength in the transversal volar grip and the maximal torque for opening the jars. Female and male subjects who were not capable of handling the electric plug in the manual ability test had significantly weaker strength in the key-grip. The importance of designing products and adapting the environment so as to correspond to the functional capacity of the elderly, is emphasized.

  14. Energy buildup in sheared force-free magnetic fields

    Science.gov (United States)

    Wolfson, Richard; Low, Boon C.

    1992-01-01

    Photospheric displacement of the footpoints of solar magnetic field lines results in shearing and twisting of the field, and consequently in the buildup of electric currents and magnetic free energy in the corona. The sudden release of this free energy may be the origin of eruptive events like coronal mass ejections, prominence eruptions, and flares. An important question is whether such an energy release may be accompanied by the opening of magnetic field lines that were previously closed, for such open field lines can provide a route for matter frozen into the field to escape the sun altogether. This paper presents the results of numerical calculations showing that opening of the magnetic field is permitted energetically, in that it is possible to build up more free energy in a sheared, closed, force-free magnetic field than is in a related magnetic configuration having both closed and open field lines. Whether or not the closed force-free field attains enough energy to become partially open depends on the form of the shear profile; the results presented compare the energy buildup for different shear profiles. Implications for solar activity are discussed briefly.

  15. Clinical Outcomes of Living Liver Transplantation According to the Presence of Sarcopenia as Defined by Skeletal Muscle Mass, Hand Grip, and Gait Speed.

    Science.gov (United States)

    Harimoto, N; Yoshizumi, T; Izumi, T; Motomura, T; Harada, N; Itoh, S; Ikegami, T; Uchiyama, H; Soejima, Y; Nishie, A; Kamishima, T; Kusaba, R; Shirabe, K; Maehara, Y

    2017-11-01

    Sarcopenia is an independent predictor of death after living-donor liver transplantation (LDLT). However, the ability of the Asian Working Group for Sarcopenia criteria for sarcopenia (defined as reduced skeletal muscle mass plus low muscle strength) to predict surgical outcomes in patients who have undergone LDLT has not been determined. This study prospectively enrolled 366 patients who underwent LDLT at Kyushu University Hospital. Skeletal muscle area (determined by computed tomography), hand-grip strength, and gait speed were measured in 102 patients before LDLT. We investigated the relationship between sarcopenia and surgical outcomes after LDLT performed in three time periods. The number of patients with lower skeletal muscle area has increased to 52.9% in recent years. The incidence of sarcopenia according to the Asian Working Group for Sarcopenia criteria was 23.5% (24/102). Patients with sarcopenia (defined by skeletal muscle area and functional parameters) had significantly lower skeletal muscle area and weaker hand-grip strength than did those without sarcopenia. Compared with non-sarcopenic patients, patients with sarcopenia also had significantly worse liver function, greater estimated blood loss, greater incidence of postoperative complications of Clavien-Dindo grade IV or greater (including amount of ascites on postoperative day 14, total bilirubin on postoperative day 14, and postoperative sepsis), and longer postoperative hospital stay. Multiple logistic regression analysis revealed sarcopenia as a significant predictor of 6-month mortality. The combination of skeletal muscle mass and function can predict surgical outcomes in LDLT patients. Copyright © 2017 Elsevier Inc. All rights reserved.

  16. Hurricane Imaging Radiometer (HIRAD) Observations of Brightness Temperatures and Ocean Surface Wind Speed and Rain Rate During NASA's GRIP and HS3 Campaigns

    Science.gov (United States)

    Miller, Timothy L.; James, M. W.; Roberts, J. B.; Jones, W. L.; Biswas, S.; Ruf, C. S.; Uhlhorn, E. W.; Atlas, R.; Black, P.; Albers, C.

    2012-01-01

    HIRAD flew on high-altitude aircraft over Earl and Karl during NASA s GRIP (Genesis and Rapid Intensification Processes) campaign in August - September of 2010, and plans to fly over Atlantic tropical cyclones in September of 2012 as part of the Hurricane and Severe Storm Sentinel (HS3) mission. HIRAD is a new C-band radiometer using a synthetic thinned array radiometer (STAR) technology to obtain spatial resolution of approximately 2 km, out to roughly 30 km each side of nadir. By obtaining measurements of emissions at 4, 5, 6, and 6.6 GHz, observations of ocean surface wind speed and rain rate can be retrieved. The physical retrieval technique has been used for many years by precursor instruments, including the Stepped Frequency Microwave Radiometer (SFMR), which has been flying on the NOAA and USAF hurricane reconnaissance aircraft for several years to obtain observations within a single footprint at nadir angle. Results from the flights during the GRIP and HS3 campaigns will be shown, including images of brightness temperatures, wind speed, and rain rate. Comparisons will be made with observations from other instruments on the campaigns, for which HIRAD observations are either directly comparable or are complementary. Features such as storm eye and eye-wall, location of storm wind and rain maxima, and indications of dynamical features such as the merging of a weaker outer wind/rain maximum with the main vortex may be seen in the data. Potential impacts on operational ocean surface wind analyses and on numerical weather forecasts will also be discussed.

  17. Grip and detachment of locusts on inverted sandpaper substrates

    International Nuclear Information System (INIS)

    Han Longbao; Wang Zhouyi; Ji Aihong; Dai Zhendong

    2011-01-01

    Locusts (Locusta migratoria manilensis) are characterized by their strong flying and grasping ability. Research on the grasping mechanism and behaviour of locusts on sloping substrates plays an important role in elucidating the mechanics of hexapod locomotion. Data on the maximum angles of slope at which locusts can grasp stably (critical angles of detachment) were obtained from high-speed video recordings at 215 fps. The grasping forces were collected by using two sensors, in situations where all left legs were standing on one and the right legs on the other sensor plate. These data were used to illustrate the grasping ability of locusts on slopes with varying levels of roughness. The grasping morphologies of locusts' bodies and tarsi were observed, and the surface roughness as well as diameters of their claw tips was measured under a microscope to account for the grasping mechanism of these insects on the sloping substrate. The results showed that the claw tips and part of the pads were in contact with the inverted substrate when the mean particle diameter was in the range of 15.3-40.5 μm. The interaction between pads and substrates may improve the stability of contact, and claw tips may play a key role in keeping the attachment reliable. A model was developed to explain the significant effects of the relative size of claw tips and mean particle diameter on grasping ability as well as the observed increase in lateral force (2.09-4.05 times greater than the normal force during detachment) with increasing slope angle, which indicates that the lateral force may be extremely important in keeping the contact reliable. This research lays the groundwork for the probable design and development of biomimetic robotics.

  18. The influence of humidity fluxes on offshore wind speed profiles

    DEFF Research Database (Denmark)

    Barthelmie, Rebecca Jane; Sempreviva, Anna Maria; Pryor, Sara

    2010-01-01

    extrapolation from lower measurements. With humid conditions and low mechanical turbulence offshore, deviations from the traditional logarithmic wind speed profile become significant and stability corrections are required. This research focuses on quantifying the effect of humidity fluxes on stability corrected...... wind speed profiles. The effect on wind speed profiles is found to be important in stable conditions where including humidity fluxes forces conditions towards neutral. Our results show that excluding humidity fluxes leads to average predicted wind speeds at 150 m from 10 m which are up to 4% higher...... than if humidity fluxes are included, and the results are not very sensitive to the method selected to estimate humidity fluxes....

  19. TEST-RETEST RELIABILITY OF HAND GRIP STRENGTH MEASUREMENT USING A JAMAR HAND DYNAMOMETER IN PATIENTS WITH ACUTE AND CHRONIC CERVICAL RADICULOPATHY

    Directory of Open Access Journals (Sweden)

    Ejazi G

    2017-12-01

    Full Text Available Background: To evaluate the test-retest reliability of Jamar hand held dynamometer for measuring handgrip strength (HGS in patients with acute and chronic cervical radiculopathy and to find out the difference in measurement of the handgrip strength between acute and chronic cervical radiculopathy. Methods: A prospective, observational and non-experimental, the comparative study design was used. A sample of 72 subjects (37 women and 35 men suffering from cervical radiculopathy were divided into two groups i.e., Group A(acute and Group B(chronic, handgrip strength was measured using Jamar hand held dynamometer on two occasions by the same rater with an interval of 7-days. Data collection was based on standard guidelines of American Society of Hand Therapists. Three gripping trials (measured in Kg with patient’s arm in standardized arm position were recorded. The data was analyzed from the mean score obtained from the sample. Result: One-way Analysis of Variance(ANOVA was used to evaluate test-retest reliability and Tukey-Kramer Multiple Comparison Test used to find the difference between handgrip strength among acute and chronic Cervical radiculopathy cases. Greater P-value (>0.05 in both testing session, as well as 95% of the confidence interval, shows the reliability of the instrument and lesser p-value (0.05 in female subjects shows no significant difference in handgrip strength between the two groups. Conclusion: Excellent test-retest reliability for hand grip strength measurement was measured in patients with acute and chronic cervical radiculopathy shows that the equipment could be used as an assessment tool for this patient and significant difference exists among male handgrip strength between acute and chronic cervical radiculopathy cases whereas no difference exists among female handgrip strength between acute and chronic cervical radiculopathy cases.

  20. Drag reduction by streamwise traveling wave-like Lorenz Force in channel flow

    International Nuclear Information System (INIS)

    Mamori, Hiroya; Fukagata, Koji

    2011-01-01

    Skin-friction drag reduction effect of traveling wave-like wall-normal Lorenz force in a fully developed turbulent channel flow is investigated by means of direct numerical simulation. A sinusoidal profile of the wall-normal body force is assumed as the Lorenz force. While upstream traveling waves reduce the drag in the case of blowing/suction, standing waves reduce it in the case of present forcing. Visualization of vortical structure under the standing wave-like wall-normal Lorenz force reveals that the near-wall streamwise vortices, which increase the skin-friction drag, disappear and spanwise roller-like vortices are generated instead. Three component decomposition of the Reynolds shear stress indicates that the spanwise roller-like vortices contribute to the negative Reynolds shear stress in the region near the wall, similarly to the case of laminar flows. While the analogy between the wall-normal and streamwise forcings can be expected, the statistics are found to exhibit different behaviors due to the difference in the energy flow.

  1. Yellowstone wolves and the forces that structure natural systems.

    Science.gov (United States)

    Dobson, Andy P

    2014-12-01

    Since their introduction in 1995 and 1996, wolves have had effects on Yellowstone that ripple across the entire structure of the food web that defines biodiversity in the Northern Rockies ecosystem. Ecological interpretations of the wolves have generated a significant amount of debate about the relative strength of top-down versus bottom-up forces in determining herbivore and vegetation abundance in Yellowstone. Debates such as this are central to the resolution of broader debates about the role of natural enemies and climate as forces that structure food webs and modify ecosystem function. Ecologists need to significantly raise the profile of these discussions; understanding the forces that structure food webs and determine species abundance and the supply of ecosystem services is one of the central scientific questions for this century; its complexity will require new minds, new mathematics, and significant, consistent funding.

  2. The efficiency of aerodynamic force production in Drosophila.

    Science.gov (United States)

    Lehmann, F O

    2001-12-01

    Total efficiency of aerodynamic force production in insect flight depends on both the efficiency with which flight muscles turn metabolic energy into muscle mechanical power and the efficiency with which this power is converted into aerodynamic flight force by the flapping wings. Total efficiency has been estimated in tethered flying fruit flies Drosophila by modulating their power expenditures in a virtual reality flight simulator while simultaneously measuring stroke kinematics, locomotor performance and metabolic costs. During flight, muscle efficiency increases with increasing flight force production, whereas aerodynamic efficiency of lift production decreases with increasing forces. As a consequence of these opposite trends, total flight efficiency in Drosophila remains approximately constant within the kinematic working range of the flight motor. Total efficiency is broadly independent of different profile power estimates and typically amounts to 2-3%. The animal achieves maximum total efficiency near hovering flight conditions, when the beating wings produce flight forces that are equal to the body weight of the insect. It remains uncertain whether this small advantage in total efficiency during hovering flight was shaped by evolutionary factors or results from functional constraints on both the production of mechanical power by the indirect flight muscles and the unsteady aerodynamic mechanisms in flapping flight.

  3. The role of concavo-convex walls of a nanopore on the density profile, adsorption, solvation force, and capillary condensation of confined fluids: A DFT study

    International Nuclear Information System (INIS)

    Helmi, Abbas; Keshavarzi, Ezat

    2014-01-01

    Highlights: • The effect of concavo-convex walls of nanopores on the density profile was studied. • For HS fluids the contact density at concave wall is greater than for convex wall. • For Yukawa fluid the contact density at concave wall can be less than convex wall. • Capillary condensation was observed for Yukawa fluids in the homocentric pores. - Abstract: We investigate the effects of concavo-convex walls of a nanopore on the structure and certain thermodynamic properties of confined fluids. Adsorption, solvation force, and capillary condensation in a nanopore formed between two homocentric spheres will be determined using the MFMT. For hard sphere fluids, contact density is greater at the concave wall than it is at the convex wall. In Yukawa fluids, for the thermodynamic state in which the energy effect is the dominant factor, contact density at a concave wall is less than that at a convex wall; this will be reversed for the thermodynamic state in which the entropy effect is the dominant factor. It is possible to find thermodynamic states in which contact densities at concave and convex walls become identical. The adsorption and solvation force of hard sphere fluid show an oscillatory behavior versus H. Capillary condensation is in certain cases observed for Yukawa fluids

  4. Gravito-Inertial Force Resolution in Perception of Synchronized Tilt and Translation

    Science.gov (United States)

    Wood, Scott J.; Holly, Jan; Zhang, Guen-Lu

    2011-01-01

    Natural movements in the sagittal plane involve pitch tilt relative to gravity combined with translation motion. The Gravito-Inertial Force (GIF) resolution hypothesis states that the resultant force on the body is perceptually resolved into tilt and translation consistently with the laws of physics. The purpose of this study was to test this hypothesis for human perception during combined tilt and translation motion. EXPERIMENTAL METHODS: Twelve subjects provided verbal reports during 0.3 Hz motion in the dark with 4 types of tilt and/or translation motion: 1) pitch tilt about an interaural axis at +/-10deg or +/-20deg, 2) fore-aft translation with acceleration equivalent to +/-10deg or +/-20deg, 3) combined "in phase" tilt and translation motion resulting in acceleration equivalent to +/-20deg, and 4) "out of phase" tilt and translation motion that maintained the resultant gravito-inertial force aligned with the longitudinal body axis. The amplitude of perceived pitch tilt and translation at the head were obtained during separate trials. MODELING METHODS: Three-dimensional mathematical modeling was performed to test the GIF-resolution hypothesis using a dynamical model. The model encoded GIF-resolution using the standard vector equation, and used an internal model of motion parameters, including gravity. Differential equations conveyed time-varying predictions. The six motion profiles were tested, resulting in predicted perceived amplitude of tilt and translation for each. RESULTS: The modeling results exhibited the same pattern as the experimental results. Most importantly, both modeling and experimental results showed greater perceived tilt during the "in phase" profile than the "out of phase" profile, and greater perceived tilt during combined "in phase" motion than during pure tilt of the same amplitude. However, the model did not predict as much perceived translation as reported by subjects during pure tilt. CONCLUSION: Human perception is consistent with

  5. Development of a disposable force-sensing glove for clinicians and demonstration of its force measurements on patients during rehabilitation following anterior cruciate ligament reconstruction surgery

    Science.gov (United States)

    Wang, Wei-Chih; Linders, David R.; Nuckley, David J.

    2017-12-01

    For many clinicians, their effectiveness is dependent on the magnitude of forces they manually apply to their patients. However, current state-of-the-art care strategies lack quantitative feedback, making it difficult to provide consistent care over time and among multiple clinicians. To provide real-time quantitative feedback to clinicians, we have developed a disposable glove with a force sensor embedded in the fingertips or palm. The sensor is based on the fiber-optic bendloss effect whereby light intensity from an infrared source is attenuated as the fiber is bent between a series of corrugated teeth. The sensor fabricated has a very low profile (10×7×1 mm) and has demonstrated high sensitivity, accuracy, range, and durability. Force feedback up to 90 N with an average force threshold at 0.19 N and average sensor resolution at 0.05 N has been demonstrated. A preliminary clinical study has also been conducted with anterior cruciate ligament reconstruction patients who show significant range of motion improvement when treated with the force-sensing glove.

  6. The Vacuum-Compacted Regolith Gripping Mechanism and Unmanned Flights via Quad-Rotors

    Science.gov (United States)

    Scott, Rollin L.

    2014-01-01

    During the course of the Kennedy Space Center Summer Internship, two main experiments were performed: The Vacuum-Compacted Regolith Gripping Mechanism and Unmanned Flights via Quad-copters. The objectives of the Vacuum-Compacted Regolith Gripping Mechanism, often abbreviated as the Granular Gripper, are to exhibit Space Technology, such as a soft robotic hand, lift different apparatuses used to excavate regolith, and conserve energy while executing its intended task. The project is being conducted to test how much weight the Granular Gripper can hold. With the use of an Animatronic Robotic Hand, Arduino Uno, and other components, the system was calibrated before actually conducting the intended weight test. The maximum weight each finger could hold with the servos running, in the order of pinky, ring, middle, and index fingers, are as follows: 1.340N, 1.456 N, 0.9579 N, and 1.358 N. Using the small vacuum pump system, the maximum weight each finger could hold, in the same order, was: 4.076 N, 6.159 N, 5.454 N, and 4.052 N. The maximum torques on each of the fingers when the servos were running, in the same respective order, was: 0.0777 Nm, 0.0533 Nm, 0.0648 Nm, and 0.0532 Nm. The maximum torques on the individual fingers, when the small vacuum pump was in effect, in the same order as above, was: 0.2318 Nm, 0.3032 Nm, 0.2741 Nm, and 0.1618 Nm. In testing all the fingers with the servos running, the total weight was 5.112 N and the maximum torque on the all the fingers was 0.2515 Nm. However, when the small vacuum pump system was used, the total weight was 19.741 N and the maximum torque on the all the fingers was 0.9713 Nm. The conclusion that was drawn stated that using the small vacuum pump system proved nearly 4 times more effective when testing how much weigh the hand could hold. The resistance provided by the compacted sand in the glove allowed more weight to be held by the hand and glove. Also, when the servos turned off and the hand still retaining its

  7. The effect of wheel eccentricity and run-out on grinding forces, waviness, wheel wear and chatter

    OpenAIRE

    O'DONNELL, GARRET; MURPHY, STUART

    2011-01-01

    PUBLISHED The effect of grinding-wheel eccentricity on grinding forces, wheel wear and final waviness height was studied. Eccentricity was evident in force oscillations and acceleration and audio measurements. A model was developed to predict final scallop-profile shape from grinding parameters and eccentricity. Recommendations are given on detecting eccentricity and determining when eccentricity is tolerable.

  8. Gravity-dependent estimates of object mass underlie the generation of motor commands for horizontal limb movements.

    Science.gov (United States)

    Crevecoeur, F; McIntyre, J; Thonnard, J-L; Lefèvre, P

    2014-07-15

    Moving requires handling gravitational and inertial constraints pulling on our body and on the objects that we manipulate. Although previous work emphasized that the brain uses internal models of each type of mechanical load, little is known about their interaction during motor planning and execution. In this report, we examine visually guided reaching movements in the horizontal plane performed by naive participants exposed to changes in gravity during parabolic flight. This approach allowed us to isolate the effect of gravity because the environmental dynamics along the horizontal axis remained unchanged. We show that gravity has a direct effect on movement kinematics, with faster movements observed after transitions from normal gravity to hypergravity (1.8g), followed by significant movement slowing after the transition from hypergravity to zero gravity. We recorded finger forces applied on an object held in precision grip and found that the coupling between grip force and inertial loads displayed a similar effect, with an increase in grip force modulation gain under hypergravity followed by a reduction of modulation gain after entering the zero-gravity environment. We present a computational model to illustrate that these effects are compatible with the hypothesis that participants partially attribute changes in weight to changes in mass and scale incorrectly their motor commands with changes in gravity. These results highlight a rather direct internal mapping between the force generated during stationary holding against gravity and the estimation of inertial loads that limb and hand motor commands must overcome. Copyright © 2014 the American Physiological Society.

  9. Profiling and Utilizing Learning Style. NASSP Learning Style Series.

    Science.gov (United States)

    Keefe, James W., Ed.

    In 1986, the National Association of Secondary School Principals, with the assistance of a national task force, published the NASSP Learning Style Profile (LSP) for diagnosis of the cognitive styles, perceptual response tendencies, and instructional preferences of middle level and senior high school students. This monograph offers a short course…

  10. Getting a Grip on the Handgrip Task: Handgrip Duration Correlates with Neuroticism But Not Conscientiousness

    Directory of Open Access Journals (Sweden)

    Simon B. Goldberg

    2017-08-01

    Full Text Available Questions regarding the replicability of key findings in the self-regulation literature (e.g., ego-depletion effect have led some to call for a more thorough evaluation of commonly used measures of self-control. The isometric handgrip task is one such measure. The current study examined correlates of handgrip persistence using data drawn from a larger randomized controlled trial. Handgrip persistence was measured both at baseline and following a physical stressor (cold pressor test. Correlations were examined between handgrip performance and personality traits theoretically closely linked with self-regulation: conscientiousness and neuroticism. Baseline handgrip performance was correlated with several measures drawn from the nomological network of self-regulation including measures of trait neuroticism, mindfulness, anxiety sensitivity, perceived stress, and positive affect, although not with trait conscientiousness. Baseline handgrip predicted aversiveness experienced during the physical stressor, while changes in handgrip performance tracked changes in implicit and explicit negative affect (i.e., affective reactivity. These associations were largely maintained when controlling for variables highly correlated with overall grip strength (i.e., gender, height, and weight, although correlations separated by gender suggest associations were primarily driven by female participants. Results support future research using the handgrip task.

  11. Interaction between local parameters of two-phase flow and random forces on a cylinder

    International Nuclear Information System (INIS)

    Sylviane Pascal-Ribot; Yves Blanchet; Franck Baj; Phillippe Piteau

    2005-01-01

    Full text of publication follows: In the frame of assessments of steam generator tube bundle vibrations, a study was conducted in order to investigate the effects of an air/water flow on turbulent buffeting forces induced on a cylinder. The main purpose is to relate the physical parameters characterizing an air/water two-phase crossflow with the structural loading of a fixed cylindrical tube. In this first approach, the experiments are carried out in a rectangular acrylic test section supplied with a vertical upward bubbly flow. This flow is transversally impeded by a fixed rigid 12,15 mm diameter cylinder. Different turbulence grids are used in order to modify two-phase characteristics such as bubble diameter, void fraction profile, fluctuation parameters. Preliminarily, a dimensional analysis of fluid-structure interaction under two-phase turbulent solicitations has enabled to identify a list of physically relevant variables which must be measured to evaluate the random forces. The meaning of these relevant parameters as well as the effect of flow patterns are discussed. Direct measurements of two-phase flow parameters are performed simultaneously with measurements of forces exerted on the cylinder. The main descriptive parameters of a two-phase flow are measured using a bi-optical probe, in particular void fraction profiles, interfacial velocities, bubble diameters, void fraction fluctuations. In the same time, the magnitude of random forces caused by two-phase flow is measured with a force transducer. A thorough analysis of the experimental data is then undertaken in order to correlate physical two-phase mechanisms with the random forces exerted on the cylinder. The hypotheses made while applying the dimensional analysis are verified and their pertinence is discussed. Finally, physical parameters involved in random buffeting forces applied on a transverse tube are proposed to scale the spectral magnitude of these forces and comparisons with other authors

  12. EFFECT OF POLARIMETRIC NOISE ON THE ESTIMATION OF TWIST AND MAGNETIC ENERGY OF FORCE-FREE FIELDS

    International Nuclear Information System (INIS)

    Tiwari, Sanjiv Kumar; Venkatakrishnan, P.; Gosain, Sanjay; Joshi, Jayant

    2009-01-01

    The force-free parameter α, also known as helicity parameter or twist parameter, bears the same sign as the magnetic helicity under some restrictive conditions. The single global value of α for a whole active region gives the degree of twist per unit axial length. We investigate the effect of polarimetric noise on the calculation of global α value and magnetic energy of an analytical bipole. The analytical bipole has been generated using the force-free field approximation with a known value of constant α and magnetic energy. The magnetic parameters obtained from the analytical bipole are used to generate Stokes profiles from the Unno-Rachkovsky solutions for polarized radiative transfer equations. Then we add random noise of the order of 10 -3 of the continuum intensity (I c ) in these profiles to simulate the real profiles obtained by modern spectropolarimeters such as Hinode (SOT/SP), SVM (USO), ASP, DLSP, POLIS, and SOLIS etc. These noisy profiles are then inverted using a Milne-Eddington inversion code to retrieve the magnetic parameters. Hundred realizations of this process of adding random noise and polarimetric inversion is repeated to study the distribution of error in global α and magnetic energy values. The results show that (1) the sign of α is not influenced by polarimetric noise and very accurate values of global twist can be calculated, and (2) accurate estimation of magnetic energy with uncertainty as low as 0.5% is possible under the force-free condition.

  13. Sensitivity of tropical convection in cloud-resolving WRF simulations to model physics and forcing procedures

    Science.gov (United States)

    Endo, S.; Lin, W.; Jackson, R. C.; Collis, S. M.; Vogelmann, A. M.; Wang, D.; Oue, M.; Kollias, P.

    2017-12-01

    Tropical convection is one of the main drivers of the climate system and recognized as a major source of uncertainty in climate models. High-resolution modeling is performed with a focus on the deep convection cases during the active monsoon period of the TWP-ICE field campaign to explore ways to improve the fidelity of convection permitting tropical simulations. Cloud resolving model (CRM) simulations are performed with WRF modified to apply flexible configurations for LES/CRM simulations. We have enhanced the capability of the forcing module to test different implementations of large-scale vertical advective forcing, including a function for optional use of large-scale thermodynamic profiles and a function for the condensate advection. The baseline 3D CRM configurations are, following Fridlind et al. (2012), driven by observationally-constrained ARM forcing and tested with diagnosed surface fluxes and fixed sea-surface temperature and prescribed aerosol size distributions. After the spin-up period, the simulations follow the observed precipitation peaks associated with the passages of precipitation systems. Preliminary analysis shows that the simulation is generally not sensitive to the treatment of the large-scale vertical advection of heat and moisture, while more noticeable changes in the peak precipitation rate are produced when thermodynamic profiles above the boundary layer were nudged to the reference profiles from the forcing dataset. The presentation will explore comparisons with observationally-based metrics associated with convective characteristics and examine the model performance with a focus on model physics, doubly-periodic vs. nested configurations, and different forcing procedures/sources. A radar simulator will be used to understand possible uncertainties in radar-based retrievals of convection properties. Fridlind, A. M., et al. (2012), A comparison of TWP-ICE observational data with cloud-resolving model results, J. Geophys. Res., 117, D05204

  14. Yellowstone wolves and the forces that structure natural systems.

    Directory of Open Access Journals (Sweden)

    Andy P Dobson

    2014-12-01

    Full Text Available Since their introduction in 1995 and 1996, wolves have had effects on Yellowstone that ripple across the entire structure of the food web that defines biodiversity in the Northern Rockies ecosystem. Ecological interpretations of the wolves have generated a significant amount of debate about the relative strength of top-down versus bottom-up forces in determining herbivore and vegetation abundance in Yellowstone. Debates such as this are central to the resolution of broader debates about the role of natural enemies and climate as forces that structure food webs and modify ecosystem function. Ecologists need to significantly raise the profile of these discussions; understanding the forces that structure food webs and determine species abundance and the supply of ecosystem services is one of the central scientific questions for this century; its complexity will require new minds, new mathematics, and significant, consistent funding.

  15. Simulation of Shuttle launch G forces and acoustic loads using the NASA Ames Research Center 20G centrifuge

    Science.gov (United States)

    Shaw, T. L.; Corliss, J. M.; Gundo, D. P.; Mulenburg, G. M.; Breit, G. A.; Griffith, J. B.

    1994-01-01

    The high cost and long times required to develop research packages for space flight can often be offset by using ground test techniques. This paper describes a space shuttle launch and reentry simulating using the NASA Ames Research Center's 20G centrifuge facility. The combined G-forces and acoustic environment during shuttle launch and landing were simulated to evaluate the effect on a payload of laboratory rates. The launch G force and acoustic profiles are matched to actual shuttle launch data to produce the required G-forces and acoustic spectrum in the centrifuge test cab where the rats were caged on a free-swinging platform. For reentry, only G force is simulated as the aero-acoustic noise is insignificant compared to that during launch. The shuttle G-force profiles of launch and landing are achieved by programming the centrifuge drive computer to continuously adjust centrifuge rotational speed to obtain the correct launch and landing G forces. The shuttle launch acoustic environment is simulated using a high-power, low-frequency audio system. Accelerometer data from STS-56 and microphone data from STS-1 through STS-5 are used as baselines for the simulations. This paper provides a description of the test setup and the results of the simulation with recommendations for follow-on simulations.

  16. Estimation of precipitation rates by measurements of {sup 36}Cl in the GRIP ice core with the PSI/ETH tandem accelerator

    Energy Technology Data Exchange (ETDEWEB)

    Wagner, G.; Baumgartner, S.; Beer, J. [EAWAG, Duebendorf (Switzerland); Synal, H.A. [Paul Scherrer Inst. (PSI), Villigen (Switzerland); Suter, M. [Eidgenoessische Technische Hochschule, Zurich (Switzerland)

    1997-09-01

    Within the European Greenland ice core project (GRIP) {sup 36}Cl AMS measurements have been performed on ice core samples from Summit (Greenland, 73{sup o}N, 37{sup o}W). Most data analysed so far are from the lower part of the ice core. The {sup 36}Cl concentration is well correlated with {delta}{sup 18}O, which is considered as a proxy for paleotemperatures. Assuming that the deposition rate of radionuclides is independent of {delta}{sup 18}O, {sup 36}Cl is used to estimate the relationship between accumulation and {delta}{sup 18}O. The results confirm that the rapid changes of {delta}{sup 18}O, the so-called Dansgaard-Oeschger events, are also reflected in the precipitation rate. (author) 1 fig., 3 refs.

  17. Coupling forces resulting from the type of chain saw used

    Directory of Open Access Journals (Sweden)

    Jolanta Malinowska-Borowska

    2014-03-01

    Full Text Available Introduction. Woodcutters’ working conditions are difficult due to the presence of numerous occupational hazards. Petrol –fuelled chain saws commonly used in forestry produce vibration, which may lead to the development of non-specific disorders in the upper extremities of the chain saw operator, referred to as hand-arm vibration syndrome (HAVS. The magnitude of coupling forces exerted on a vibrating tool handle may affect the severity of HAVS and hand-wrist cumulative trauma disorders. The aim of the presented study was to measure coupling forces exerted by fellers on various chain saws and to find correlation between force magnitude and type of tool used. Material and methods. Coupling forces applied by workers on different types of chain saws were measured by means of a hydro-electronic force meter. All measurements were carried out during the harvesting of wood in real work conditions. Results. Mean force applied by forestry workers on their tools was 44.2 N. Coupling forces registered during cutting wood with small universal chain saws were larger than forces exerted on models characterized by higher power profile. Forces applied on comparable tools produced by various manufacturers also differed. Conclusions. The relationship between coupling forces and power of the chain saw should lead to ergonomic improvements of the tool and vibration-reducing devices. These results can also be used as a recommendation for fellers in a range of using proper machines for different types of cut or types of wood. They may also be applicable to develop more effective methods for assessing vibration exposure risks among woodcutters.

  18. The influence of sodium bicarbonate on maximal force and rates of force development in the triceps surae and brachii during fatiguing exercise.

    Science.gov (United States)

    Siegler, Jason C; Mudie, Kurt; Marshall, Paul

    2016-11-01

    What is the central question of this study? Does metabolic alkalosis in humans, induced by sodium bicarbonate, affect rates of skeletal muscle fatigue differentially in muscle groups composed predominately of slow- and fast-twitch fibres? What is the main finding and its importance? Sodium bicarbonate exhibited no effect on the fatigue profile observed between triceps surae and brachii muscle groups during and after 2 min of tetanic stimulation. For the first time in exercising humans, we have profiled the effect of sodium bicarbonate on the voluntary and involuntary contractile characteristics of muscle groups representative of predominately slow- and fast-twitch fibres. The effect of metabolic alkalosis on fibre-specific maximal force production and rates of force development (RFD) has been investigated previously in animal models, with evidence suggesting an improved capacity to develop force rapidly in fast- compared with slow-twitch muscle. We have attempted to model in vivo the fatigue profile of voluntary and involuntary maximal force and RFD in the triceps surae and brachii after sodium bicarbonate (NaHCO 3 ) ingestion. In a double-blind, three-way repeated-measures design, participants (n = 10) ingested either 0.3 g kg -1 NaHCO 3 (ALK) or equivalent calcium carbonate (PLA) prior to 2 min of continuous (1 Hz) supramaximal stimulation (300 ms at 40 Hz) of the triceps surae or brachii, with maximal voluntary efforts (maximal voluntary torque) coupled with direct muscle stimulation also measured at baseline, 1 and 2 min. Metabolic alkalosis was achieved in both ALK trials but was not different between muscle groups. Regardless of the conditions, involuntary torque declined nearly 60% in the triceps brachii (P < 0.001) and ∼30% in the triceps surae (P < 0.001). In all trials, there was a significant decline in normalized involuntary RFD (P < 0.05). Maximal voluntary torque declined nearly 28% but was not different between conditions (P < 0

  19. Motor performance in children with Noonan syndrome.

    Science.gov (United States)

    Croonen, Ellen A; Essink, Marlou; van der Burgt, Ineke; Draaisma, Jos M; Noordam, Cees; Nijhuis-van der Sanden, Maria W G

    2017-09-01

    Although problems with motor performance in daily life are frequently mentioned in Noonan syndrome, the motor performance profile has never been systematically investigated. The aim of this study was to examine whether a specific profile in motor performance in children with Noonan syndrome was seen using valid norm-referenced tests. The study assessed motor performance in 19 children with Noonan syndrome (12 females, mean age 9 years 4 months, range 6 years 1 month to 11 years and 11 months, SDS 1 year and 11 months). More than 60% of the parents of the children reported pain, decreased muscle strength, reduced endurance, and/or clumsiness in daily functioning. The mean standard scores on the Visual Motor Integration (VMI) test and Movement Assessment Battery for Children 2, Dutch version (MABC-2-NL) items differed significantly from the reference scores. Grip strength, muscle force, and 6 min Walking Test (6 MWT) walking distance were significantly lower, and the presence of generalized hypermobility was significantly higher. All MABC-2-NL scores (except manual dexterity) correlated significantly with almost all muscle strength tests, VMI total score, and VMI visual perception score. The 6 MWT was only significantly correlated to grip strength. This is the first study that confirms that motor performance, strength, and endurance are significantly impaired in children with Noonan syndrome. Decreased functional motor performance seems to be related to decreased visual perception and reduced muscle strength. Research on causal relationships and the effectiveness of interventions is needed. Physical and/or occupational therapy guidance should be considered to enhance participation in daily life. © 2017 Wiley Periodicals, Inc.

  20. Design optimization of piezoresistive cantilevers for force sensing in air and water

    Science.gov (United States)

    Doll, Joseph C.; Park, Sung-Jin; Pruitt, Beth L.

    2009-01-01

    Piezoresistive cantilevers fabricated from doped silicon or metal films are commonly used for force, topography, and chemical sensing at the micro- and macroscales. Proper design is required to optimize the achievable resolution by maximizing sensitivity while simultaneously minimizing the integrated noise over the bandwidth of interest. Existing analytical design methods are insufficient for modeling complex dopant profiles, design constraints, and nonlinear phenomena such as damping in fluid. Here we present an optimization method based on an analytical piezoresistive cantilever model. We use an existing iterative optimizer to minimimize a performance goal, such as minimum detectable force. The design tool is available as open source software. Optimal cantilever design and performance are found to strongly depend on the measurement bandwidth and the constraints applied. We discuss results for silicon piezoresistors fabricated by epitaxy and diffusion, but the method can be applied to any dopant profile or material which can be modeled in a similar fashion or extended to other microelectromechanical systems. PMID:19865512