WorldWideScience

Sample records for grin lens multimode

  1. Using GRIN to save 50% lens weight for an 8x rifle scope design

    Science.gov (United States)

    Flynn, R. A.; Beadie, G.

    2017-05-01

    Starting with a literature-based design for a rifle scope, we demonstrate the potential to replace large, heavy glass lenses with polymer-based GRIN lenses with little optical penalty, while saving 50% of the lens weight in the system. Several properties of the primary design are chosen to favor manufacturability, such as leaving glass for the external surfaces and choosing polymers and GRIN geometries based on proven fabrication techniques. Compared to the reference design which weighed 154 g, the GRIN-substituted design weighed 78 g while maintaining visually constant performance from 0-40°C.

  2. Three-photon excited fluorescence imaging of unstained tissue using a GRIN lens endoscope.

    Science.gov (United States)

    Huland, David M; Charan, Kriti; Ouzounov, Dimitre G; Jones, Jason S; Nishimura, Nozomi; Xu, Chris

    2013-05-01

    We present a compact and portable three-photon gradient index (GRIN) lens endoscope system suitable for imaging of unstained tissues, potentially deep within the body, using a GRIN lens system of 1 mm diameter and 8 cm length. The lateral and axial resolution in water is 1.0 μm and 9.5 μm, respectively. The ~200 μm diameter field of view is imaged at 2 frames/s using a fiber-based excitation source at 1040 nm. Ex vivo imaging is demonstrated with unstained mouse lung at 5.9 mW average power. These results demonstrate the feasibility of three-photon GRIN lens endoscopy for optical biopsy.

  3. Thin gas cell with GRIN fiber lens for intra-cavity fiber laser gas sensors

    Science.gov (United States)

    Li, Mo; Dai, Jing-min; Peng, Gang-ding

    2009-07-01

    Fiber laser gas sensors based on the intra-cavity absorption spectroscopy require the use of gas cells. We propose a simple and reliable gas cell using graded-index fiber lens (GFL) based all-fiber collimator. Conventional gas cells usually utilize direct fiber-to-fiber coupling without collimators or graded-index (GRIN) lens as collimators. Direct fiberto- fiber gas cell has simple configuration, but it suffers from high coupling loss and stray light interference. Gas cells applying fiber pigtailed GRIN lens are advantageous to achieve low coupling loss. However, fiber pigtailed GRIN lens requires accurate and complicated alignment and glue packaging which could compromise long term reliability and thermal stability. The proposed technique fabricates all-fiber collimators by simply splicing a short section of gradedindex fiber to single mode fiber which is both compact and durable. With that collimator, the gas cell can be fabricated very thin and are suitable for extreme environments with high temperature and vibration. In this paper, we have carried out experiment and analysis to evaluate the proposed technique. The coupling efficiency is studied versus different GFL gradient parameter profiles using ray matrix transformation of the complex beam parameter. Experiments are also done to prove the practical feasibility of the collimator. The analysis indicates that gas cell using GFLs can overcome the disadvantages of traditional design; it may replace the conventional gas cells in practical applications.

  4. Two-photon excited fluorescence microendoscopic imaging using a GRIN lens

    Science.gov (United States)

    Yan, Wei; Peng, Xiao; Lin, Danying; Wang, Qi; Gao, Jian; Zhou, Jie; Ye, Tong; Qu, Junle; Niu, Hanben

    2015-03-01

    With the rapid development of life sciences, there is an increasing demand for intravital fluorescence imaging of small animals. However, large dimensions and limited working distances of objective lenses in traditional fluorescence microscopes have limited the imaging applications mostly to superficial tissues. To overcome this disadvantage, researchers have developed the graded-index (GRIN) probes with small diameters for imaging internal organs of small animals in a minimally invasive fashion. Here, we present the development of a fluorescence endoscopic imaging system based on a GRIN lens using two-photon excitation. Experimental results showed that this system could perform dynamic fluorescence microendoscopic imaging and monitor the blood flow in anesthetized living mice using two-photon excitation.

  5. A Bio-Inspired Polymeric Gradient Refractive Index (GRIN) Human Eye Lens

    Science.gov (United States)

    2012-11-19

    optical model of the crystalline lens and eye of the octopus ,” Vision Res. 39(17), 2841–2852 (1999). 5. D. E. Nilsson, L. Gislén, M. M. Coates, C...aberrations [1]. Biological examples of GRIN lenses include spherical eye lenses found in aquatic creatures such as fish, octopus , squid, and jellyfish [2–5...µATR-FTIR examination by exhuming cross sections of adjacent sheet material. The µATR-FTIR technique can map the relative composition across the cross

  6. A new low-voltage-driven GRIN liquid crystal lens with multiple ring electrodes in unequal widths.

    Science.gov (United States)

    Kao, Yung-Yuan; Chao, Paul C-P; Hsueh, Chieh-Wen

    2010-08-30

    This work is dedicated to design a novel liquid crystal (LC) lens device with multiple ring electrodes in unequal widths, in order to offer tunability on focusing quality and to lower the level of applied voltage. The number and widths of the multiple ring electrodes are pre-designed and optimized to offer the on-line tunability on individual electrode voltages to render a better refraction index distribution for focusing, as compared to the past hole-type LC lenses. The resulted refractive index distribution is expected to offer similar focusing effects based on the theory of the gradient refraction index (GRIN) lens. The transparent electrodes of this new LC lens are placed at the inner surface of the LC cell to minimize the driving voltages, in results, less than 10 V, for the same level of focusing power and an easy practical operation. A new fabrication process in the wafer level to bury bus lines is developed for generating smooth electrical fields over the lens aperture. In addition, a dielectric layer is coated between electrodes and the LC layer.

  7. Numerical analysis of GRIN lens based miniature probes for optical coherence tomography%基于GRIN镜头的小型OCT探头的数值分析

    Institute of Scientific and Technical Information of China (English)

    王驰; 毛幼馨; 唐智; 方臣; 于瀛洁; 齐博

    2011-01-01

    Numerical simulation technology was investigated by using the optical software GLAD to design Gradient Index(GRIN)lens based miniature probes for imaging of Optical Coherence Tomography(OCT).Firstly,the basic features of the GRIN lens were overviewed,and design methods for GRIN lens based optical probes were discussed.Then,the probe model consisting of a single mode fiber,a glass rod spacer and a GRIN lens were simulated.The simulating results show that the numerical simulation technique using GLAD can provide an intuitive and effective method for design of miniaturized probes and verification of their optical performance.In addition,the spacer can improve the optical properties of the GRIN lens based optical probes for there exists a suitable range of the spacer lengths in the glass rod.It shows that the working distance of the probe will be greater than 1.0 mm and the focus spot size less than 40 μm when the constant length of GRIN lens is to be 0.1 mm and the spacer length range from 0.8 to 1.1 mm.%利用光学软件GLAD的数值仿真技术设计了用于光学相干层析技术成像的基于梯度折射率(GRIN)镜头的小型化探头.首先,简述了梯度折射率镜头的基本特性,讨论了基于梯度折射率镜头的光学探头的设计方法;然后,对由单模光纤、玻璃棒隔片和梯度折射率镜头构成的探头模型进行了仿真.结果显示,利用GLAD的数值仿真技术为小型化探头的设计及其光学性能的验证提供了一种直观而有效的方法.另外,玻璃棒隔片存在一个适当的长度范围,可以改善设计的光学探头的传光性能.在所给仿真条件下,如设定梯度折射率镜头长0.1 mm、玻璃棒隔片长度为0.8~1.1 mm,则探头的工作距离将超过1.0 mm,而聚焦光斑的尺寸<40 μm.

  8. Third-order aberrations in GRIN crystalline lens: a new method based on axial and field rays.

    Science.gov (United States)

    Río, Arturo Díaz Del; Gómez-Reino, Carlos; Flores-Arias, M Teresa

    2015-01-01

    This paper presents a new procedure for calculating the third-order aberration of gradient-index (GRIN) lenses that combines an iterative numerical method with the Hamiltonian theory of aberrations in terms of two paraxial rays with boundary conditions on general curved end surfaces and, as a second algebraic step has been presented. Application of this new method to a GRIN human is analyzed in the framework of the bi-elliptical model. The different third-order aberrations are determined, except those that need for their calculation skew rays, because the study is made only for meridional rays.

  9. GRIN2B encephalopathy

    DEFF Research Database (Denmark)

    Platzer, Konrad; Yuan, Hongjie; Schütz, Hannah

    2017-01-01

    presented with neurodevelopmental disorders and a spectrum of hypotonia, movement disorder, cortical visual impairment, cerebral volume loss and epilepsy. Six patients presented with a consistent malformation of cortical development (MCD) intermediate between tubulinopathies and polymicrogyria. Missense...... treatment response in the respective patients still remains to be demonstrated. CONCLUSIONS: In addition to previously known features of intellectual disability, epilepsy and autism, we found evidence that GRIN2B encephalopathy is also frequently associated with movement disorder, cortical visual impairment...

  10. Design and simulation of GRIN objective lenses for an imaging fiber based speckle metrology system

    Science.gov (United States)

    Prabhathan, P.; Guru Prasad, A. S.; Haridas, Aswin; Chan, Kelvin H. K.; Murukeshan, V. M.

    2016-11-01

    Gradient-Index (GRIN) lenses are characterized by its small diameter and length, enabling them to be an effective lens for an integrated probe based imaging system. For a speckle-based surface metrology system, the imaging lens plays an important role in deciding the statistical dimensions of the speckles. In such cases, the design and simulation of the lens system would be a key process to better the performance of the lensed imaging fiber probe. In this context, this paper focuses on the design of lensed fiber probes for a speckle-based surface metrological imaging system that can find intra cavity interrogation applications. Different optical properties of GRIN lenses and imaging fibers are considered while designing the final probe distal end to meet the targeted specifications. Singlet GRIN lens configuration is analyzed for a front view configuration and a parameter optimization has been carried out to obtain the specifications including the field-of-view, resolution, working distance and magnification.

  11. Multimodality

    DEFF Research Database (Denmark)

    Buhl, Mie

    2010-01-01

    In this paper, I address an ongoing discussion in Danish E-learning research about how to take advantage of the fact that digital media facilitate other communication forms than text, so-called ‘multimodal' communication, which should not be confused with the term ‘multimedia'. While multimedia...... on their teaching and learning situations. The choices they make involve e-learning resources like videos, social platforms and mobile devices, not just as digital artefacts we interact with, but the entire practice of using digital media. In a life-long learning perspective, multimodality is potentially very...... represent the use of various media for communication, multimodality refers to the different symbol systems we employ in communication practices. As new educational practices emerge from the application of ICT, multimodality becomes a matter for all teachers when they plan, practice and reflect...

  12. Multimodality

    DEFF Research Database (Denmark)

    Buhl, Mie

    2010-01-01

    on their teaching and learning situations. The choices they make involve e-learning resources like videos, social platforms and mobile devices, not just as digital artefacts we interact with, but the entire practice of using digital media. In a life-long learning perspective, multimodality is potentially very...... represent the use of various media for communication, multimodality refers to the different symbol systems we employ in communication practices. As new educational practices emerge from the application of ICT, multimodality becomes a matter for all teachers when they plan, practice and reflect......In this paper, I address an ongoing discussion in Danish E-learning research about how to take advantage of the fact that digital media facilitate other communication forms than text, so-called ‘multimodal' communication, which should not be confused with the term ‘multimedia'. While multimedia...

  13. Multimodality

    DEFF Research Database (Denmark)

    Buhl, Mie

    In this paper, I address an ongoing discussion in Danish E-learning research about how to take advantage of the fact that digital media facilitate other communication forms than text, so-called ‘multimodal’ communication, which should not be confused with the term ‘multimedia’. While multimedia...... and learning situations. The choices they make involve E-learning resources like videos, social platforms and mobile devices, not just as digital artefacts we interact with, but the entire practice of using digital media. In a life-long learning perspective, multimodality is potentially very useful...... represent the use of various media for communication, multimodality refers to the different symbol systems we employ in communication practices. As new educational practices emerge from the application of ICT, all teachers address multimodality when they plan, practice and reflect on their teaching...

  14. Multimodality

    DEFF Research Database (Denmark)

    Buhl, Mie

    and learning situations. The choices they make involve E-learning resources like videos, social platforms and mobile devices, not just as digital artefacts we interact with, but the entire practice of using digital media. In a life-long learning perspective, multimodality is potentially very useful...... represent the use of various media for communication, multimodality refers to the different symbol systems we employ in communication practices. As new educational practices emerge from the application of ICT, all teachers address multimodality when they plan, practice and reflect on their teaching......In this paper, I address an ongoing discussion in Danish E-learning research about how to take advantage of the fact that digital media facilitate other communication forms than text, so-called ‘multimodal’ communication, which should not be confused with the term ‘multimedia’. While multimedia...

  15. Biomimetic Gradient Index (GRIN) Lenses

    Science.gov (United States)

    2006-01-01

    optics include single lenses inspired by cephalopod (octopus) eyes and a three-lens, wide field of view, optical system for a surveillance sensor...camera. Details are easily resolv- able with the polymer lens. This lens system was installed on an Evolution unmanned aerial vehicle (UAV) with a...lens system was installed in an NRL Evolution UAV and used to record video images at a height of up to 1000 ft. The index gradients in the polymer

  16. Delineating the GRIN1 phenotypic spectrum

    Science.gov (United States)

    Geider, Kirsten; Helbig, Katherine L.; Heyne, Henrike O.; Schütz, Hannah; Hentschel, Julia; Courage, Carolina; Depienne, Christel; Nava, Caroline; Heron, Delphine; Møller, Rikke S.; Hjalgrim, Helle; Lal, Dennis; Neubauer, Bernd A.; Nürnberg, Peter; Thiele, Holger; Kurlemann, Gerhard; Arnold, Georgianne L.; Bhambhani, Vikas; Bartholdi, Deborah; Pedurupillay, Christeen Ramane J.; Misceo, Doriana; Frengen, Eirik; Strømme, Petter; Dlugos, Dennis J.; Doherty, Emily S.; Bijlsma, Emilia K.; Ruivenkamp, Claudia A.; Hoffer, Mariette J.V.; Goldstein, Amy; Rajan, Deepa S.; Narayanan, Vinodh; Ramsey, Keri; Belnap, Newell; Schrauwen, Isabelle; Richholt, Ryan; Koeleman, Bobby P.C.; Sá, Joaquim; Mendonça, Carla; de Kovel, Carolien G.F.; Weckhuysen, Sarah; Hardies, Katia; De Jonghe, Peter; De Meirleir, Linda; Milh, Mathieu; Badens, Catherine; Lebrun, Marine; Busa, Tiffany; Francannet, Christine; Piton, Amélie; Riesch, Erik; Biskup, Saskia; Vogt, Heinrich; Dorn, Thomas; Helbig, Ingo; Michaud, Jacques L.; Laube, Bodo; Syrbe, Steffen

    2016-01-01

    Objective: To determine the phenotypic spectrum caused by mutations in GRIN1 encoding the NMDA receptor subunit GluN1 and to investigate their underlying functional pathophysiology. Methods: We collected molecular and clinical data from several diagnostic and research cohorts. Functional consequences of GRIN1 mutations were investigated in Xenopus laevis oocytes. Results: We identified heterozygous de novo GRIN1 mutations in 14 individuals and reviewed the phenotypes of all 9 previously reported patients. These 23 individuals presented with a distinct phenotype of profound developmental delay, severe intellectual disability with absent speech, muscular hypotonia, hyperkinetic movement disorder, oculogyric crises, cortical blindness, generalized cerebral atrophy, and epilepsy. Mutations cluster within transmembrane segments and result in loss of channel function of varying severity with a dominant-negative effect. In addition, we describe 2 homozygous GRIN1 mutations (1 missense, 1 truncation), each segregating with severe neurodevelopmental phenotypes in consanguineous families. Conclusions: De novo GRIN1 mutations are associated with severe intellectual disability with cortical visual impairment as well as oculomotor and movement disorders being discriminating phenotypic features. Loss of NMDA receptor function appears to be the underlying disease mechanism. The identification of both heterozygous and homozygous mutations blurs the borders of dominant and recessive inheritance of GRIN1-associated disorders. PMID:27164704

  17. Acquired epileptic opercular syndrome related to a heterozygous deleterious substitution in GRIN2A.

    Science.gov (United States)

    Sculier, Claudine; Tilmant, Anne-Sophie; De Tiège, Xavier; Giurgea, Sanda; Paquier, Philippe; Rudolf, Gabrielle; Lesca, Gaetan; Van Bogaert, Patrick

    2017-08-23

    Epileptic encephalopathies with continuous spike-and-waves during sleep (CSWS) are characterized by cognitive or language impairment, and are occasionally associated with pathogenic variants of the GRIN2A gene. In these disorders, speech dysfunction could be either related to cerebral dysfunction caused by the GRIN2A deleterious variant or intense interictal epileptic activity. Here, we present a patient with apraxia of speech, clearly linked to severity of epilepsy, carrying a GRIN2A variant. A 6-year-old boy developed acute regression of expressive language following epileptic seizures, leading to complete mutism, at which time EEG revealed CSWS. MEG showed bilateral superior parietal and opercular independent CSWS onsets and PET with fluorodeoxyglucose demonstrated significant increase in relative glucose metabolism in bilateral superior parietal regions. Corticosteroids induced a regression of CSWS together with impressive improvement in speech abilities. This case supports the hypothesis of a triggering role for epileptic discharges in speech deterioration observed in children carrying a deleterious variant of GRIN2A. When classic antiepileptic drugs fail to control epileptic activity, corticosteroids should be considered. Multimodal functional neuroimaging suggests a role for opercular and superior parietal areas in acquired epileptic opercular syndrome. [Published with video sequences on www.epilepticdisorders.com].

  18. MATLAB GUI (graphical user interface) for the design of GRIN components for optical systems as an educational tool

    Science.gov (United States)

    Gómez-Varela, A. I.; Bao-Varela, C.

    2014-07-01

    New technologies and the available computing tools are becoming more important every day in the teaching evolution. The use of Graphical User Interfaces (GUI) with MATLAB enables the implementation of practical teaching methodologies to make easier the comprehension of a given subject. In this work, we report on the application of GUIs in order to provide the students with a simple tool for a better understanding on how to design GRIN elements for optical systems. Another GUIs advantage is that they can be converted to an executable file, so any student could use the interface in their own computer without having a MATLAB license. We present a graphical interface to show the performance of an optical device for controlling beam size and for deflecting light for coupling purposes, by a simple geometrical optics study, in a tapered GRIN lens illuminated by a parallel beam of tilted rays. We also show a graphical interface to obtain the maximum coupling efficiency between fundamental modes of two single-mode fibers by a scaling operation carried out by a GRIN fiber lens. With this interface the students can vary the magnification and the image plane in order to get the more suitable GRIN fiber lens to maximize the coupling efficiency between two fibers.

  19. Investigation of GRIN2A in common epilepsy phenotypes

    NARCIS (Netherlands)

    Lal, Dennis; Steinbrücker, Sandra; Schubert, Julian; Sander, Thomas; Becker, Felicitas; Weber, Yvonne; Lerche, Holger; Thiele, Holger; Krause, Roland; Lehesjoki, Anna Elina; Nürnberg, Peter; Palotie, Aarno; Neubauer, Bernd A.; Muhle, Hiltrud; Stephani, Ulrich; Helbig, Ingo; Becker, Albert J.; Schoch, Susanne; Hansen, Jörg; Dorn, Thomas; Hohl, Christin; Lüscher, Nicole; von Spiczak, Sarah; Lemke, Johannes R.; Zimprich, Fritz; Feucht, Martha; Suls, Arvid; Weckhuysen, Sarah; Claes, Lieve; Deprez, Liesbet; Smets, Katrien; Dyck, Tine Van; Deconinck, Tine; De Jonghe, Peter; Møller, Rikke S.; Klitten, Laura L.; Hjalgrim, Helle; Campus, Kiel; Ostertag, Philipp; Trucks, Hol ger; Elger, Christian E.; Kleefuß-Lie, Ailing A.; Kunz, Wolfram S.; Surges, Rainer; Gaus, Verena; Janz, Dieter; Schmitz, Bettina; Klein, Karl Martin; Reif, Philipp S.; Oertel, Wolfgang H.; Hamer, Hajo M.; Rosenow, Felix; Kapser, Claudia; Schankin, Christoph J.; Koeleman, Bobby P C; de Kovel, Carolien; Lindhout, Dick; Reinthaler, Eva M.; Steinboeck, Hannelore; Neo-phytou, Birgit; Geldner, Julia; Gruber-Sedlmayr, Ursula; Haberlandt, Edda; Ronen, Gabriel M.; Altmueller, Janine; Nuernberg, Peter; Neubauer, Bernd; Sirén, Auli

    2015-01-01

    Recently, mutations and deletions in the GRIN2A gene have been identified to predispose to benign and severe idiopathic focal epilepsies (IFE), revealing a higher incidence of GRIN2A alterations among the more severe phenotypes. This study aimed to explore the phenotypic boundaries of GRIN2A mutatio

  20. Achrotech: achromat cost versus performance for conventional, diffractive, and GRIN components

    Science.gov (United States)

    Morris, Jeffrey; Wolf, Greg; Vandendriessche, Stefaan; Sparrold, Scott

    2016-09-01

    An achromatic component shares a common focus at two wavelengths and is a commonly used device in optical assemblies. This work explores the cost versus performance tradeoff for several types of achromatic lenses: conventional doublets with homogenous glass elements, hybrid doublets with a diffractive surface, axial GRadient INdex (GRIN) lenses (where the index of refraction changes along the length of the lens), and radial GRIN lenses (where the index of refraction changes depending on radial position). First order achromatic principles will be reviewed and applied to each system as a starting point and refined through the use of ray trace software. Optical performance will be assessed in terms of focusing efficiency and imaging. Cost will then be evaluated by accounting for current manufacturing costs and retail price through several distributors.

  1. Contribution of the gradient refractive index and shape to the crystalline lens spherical aberration and astigmatism.

    Science.gov (United States)

    Birkenfeld, Judith; de Castro, Alberto; Ortiz, Sergio; Pascual, Daniel; Marcos, Susana

    2013-06-28

    The optical properties of the crystalline lens are determined by its shape and refractive index distribution. However, to date, those properties have not been measured together in the same lens, and therefore their relative contributions to optical aberrations are not fully understood. The shape, the optical path difference, and the focal length of ten porcine lenses (age around 6 months) were measured in vitro using Optical Coherence Tomography and laser ray tracing. The 3D Gradient Refractive Index distribution (GRIN) was reconstructed by means of an optimization method based on genetic algorithms. The optimization method searched for the parameters of a 4-variable GRIN model that best fits the distorted posterior surface of the lens in 18 different meridians. Spherical aberration and astigmatism of the lenses were estimated using computational ray tracing, with the reconstructed GRIN lens and an equivalent homogeneous refractive index. For all lenses the posterior radius of curvature was systematically steeper than the anterior one, and the conic constant of both the anterior and posterior positive surfaces was positive. In average, the measured focal length increased with increasing pupil diameter, consistent with a crystalline lens negative spherical aberration. The refractive index of nucleus and surface was reconstructed to an average value of 1.427 and 1.364, respectively, for 633 nm. The results of the GRIN reconstruction showed a wide distribution of the index in all lens samples. The GRIN shifted spherical aberration towards negative values when compared to a homogeneous index. A negative spherical aberration with GRIN was found in 8 of the 10 lenses. The presence of GRIN also produced a decrease in the total amount of lens astigmatism in most lenses, while the axis of astigmatism was only little influenced by the presence of GRIN. To our knowledge, this study is the first systematic experimental study of the relative contribution of geometry and GRIN to

  2. Diffusion studies of anamorphic GRIN lenses

    Science.gov (United States)

    Sekh, Md. Asraful; SoodBiswas, Nisha; Sarkar, Samir; Basuray, Amitabha

    2016-12-01

    The present paper reports the diffusion study of cylindrical GRIN rod with elliptical cross section, developed by ion exchange process. The diffusion equation takes the form of Mathieu equations when transform into elliptic coordinate system and the solutions are derived in terms of angular and radial Mathieu functions. Computations of eigenvalues and expansion coefficients as well as angular and radial Mathieu functions are made which shows good agreement with the existing results. Simpler expression for ionic concentration is derived using asymptotic formulae of the functions which are used for final computation of ionic concentration of diffusing cations in elliptic GRIN. The plot of change in concentration versus diffusion depth along different directions approximately correlates with the results obtained by an earlier experimental study.

  3. Delineating the GRIN1 phenotypic spectrum

    DEFF Research Database (Denmark)

    Lemke, Johannes R; Geider, Kirsten; Helbig, Katherine L

    2016-01-01

    OBJECTIVE: To determine the phenotypic spectrum caused by mutations in GRIN1 encoding the NMDA receptor subunit GluN1 and to investigate their underlying functional pathophysiology. METHODS: We collected molecular and clinical data from several diagnostic and research cohorts. Functional conseque......OBJECTIVE: To determine the phenotypic spectrum caused by mutations in GRIN1 encoding the NMDA receptor subunit GluN1 and to investigate their underlying functional pathophysiology. METHODS: We collected molecular and clinical data from several diagnostic and research cohorts. Functional......, severe intellectual disability with absent speech, muscular hypotonia, hyperkinetic movement disorder, oculogyric crises, cortical blindness, generalized cerebral atrophy, and epilepsy. Mutations cluster within transmembrane segments and result in loss of channel function of varying severity...

  4. Analysis of fiber lens with gradient index based on thin lens equivalence

    Institute of Scientific and Technical Information of China (English)

    ZHANG Rui-feng; GE Chun-feng; LI Shi-chen

    2006-01-01

    Theoretical analysis of the fiber-lens TEC (Thermally Expended Core) /Coreless/GRIN (Graded-Index) based on thin lens equivalence is presented in this paper.On condition that the TEC part adjusts the waist radius of an incident Gaussian beam,that the coreless part controlls the space between the beam waist and the thin lens,and that the GRIN part acts as the thin lens with its focal length determined by fiber index distribution parameter g,the analytic expressions of the waist spot size and the working distance of the output Gaussian beam are derived,and the influence of the coreless fiber and the length of the GRIN fiber upon the fiber-lens parameter is discussed based on the numerical simulation results.It is concluded that,if a GRIN style fiber-lens is used as a collimator,the maximum of the spot waist can be up to 80 μm and the divergence angle of single-mode optical fiber can be reduced by 8 times.If it is applied to a MEMS device, the maximum working distance can be up to 3 mm.

  5. Epilepsy in patients with GRIN2A alterations

    DEFF Research Database (Denmark)

    von Stülpnagel, Celina; Ensslen, M; Møller, R S

    2017-01-01

    OBJECTIVE: To delineate the genetic, neurodevelopmental and epileptic spectrum associated with GRIN2A alterations with emphasis on epilepsy treatment. METHODS: Retrospective study of 19 patients (7 females; age: 1-38 years; mean 10.1 years) with epilepsy and GRIN2A alteration. Genetic variants we...

  6. Grin1 receptor deletion within CRF neurons enhances fear memory.

    Directory of Open Access Journals (Sweden)

    Georgette Gafford

    Full Text Available Corticotropin releasing factor (CRF dysregulation is implicated in mood and anxiety disorders such as posttraumatic stress disorder (PTSD. CRF is expressed in areas engaged in fear and anxiety processing including the central amygdala (CeA. Complicating our ability to study the contribution of CRF-containing neurons to fear and anxiety behavior is the wide variety of cell types in which CRF is expressed. To manipulate specific subpopulations of CRF containing neurons, our lab has developed a mouse with a Cre recombinase gene driven by a CRF promoter (CRFp3.0Cre (Martin et al., 2010. In these studies, mice that have the gene that encodes NR1 (Grin1 flanked by loxP sites (floxed were crossed with our previously developed CRFp3.0Cre mouse to selectively disrupt Grin1 within CRF containing neurons (Cre+/fGrin1+. We find that disruption of Grin1 in CRF neurons did not affect baseline levels of anxiety, locomotion, pain sensitivity or exploration of a novel object. However, baseline expression of Grin1 was decreased in Cre+/fGrin1+ mice as measured by RTPCR. Cre+/fGrin1+ mice showed enhanced auditory fear acquisition and retention without showing any significant effect on fear extinction. We measured Gria1, the gene that encodes AMPAR1 and the CREB activator Creb1 in the amygdala of Cre+/fGrin1+ mice after fear conditioning. Both Gria1 and Creb1 were enhanced in the amygdala after training. To determine if the Grin1-expressing CRF neurons within the CeA are responsible for the enhancement of fear memory in adults, we infused a lentivirus with Cre driven by a CRF promoter (LV pCRF-Cre/fGrin1+ into the CeA of floxed Grin1 mice. Cre driven deletion of Grin1 specifically within CRF expressing cells in the CeA also resulted in enhanced fear memory acquisition and retention. Altogether, these findings suggest that selective disruption of Grin1 within CeA CRF neurons strongly enhances fear memory.

  7. Propagation of Gaussian Beams through Active GRIN Materials

    Energy Technology Data Exchange (ETDEWEB)

    Gomez-Varela, A I; Flores-Arias, M T; Bao-Varela, C; Gomez-Reino, C [Grupo de ' Microoptica y Optica GRIN' , Unidad asociada al Instituto de Ciencias de Materiales de Aragon, ICMA/CSIC, Zaragoza, Espana y Escuela de Optica y OptometrIa, Campus Sur s/n, Universidade de Santiago, E15782 Santiago de Compostela (Spain); De la Fuente, X, E-mail: maite.flores@usc.es [Instituto de Ciencia de Materiales de Aragon (Universidad de Zaragoza-CSIC), Maria de Luna 3, E50018 Zaragoza (Spain)

    2011-01-01

    We discussed light propagation through an active GRIN material that exhibits loss or gain. Effects of gain or loss in GRIN materials can be phenomenologically taken into account by using a complex refractive index in the wave equation. This work examines the implication of using a complex refractive index on light propagation in an active GRIN material illuminated by a non-uniform monochromatic wave described by a Gaussian beam. We analyze how a Gaussian beam is propagated through the active material in order to characterize it by the beam parameters and the transverse irradiance distribution.

  8. Gradient-index phononic crystal lens-based enhancement of elastic wave energy harvesting

    Science.gov (United States)

    Tol, S.; Degertekin, F. L.; Erturk, A.

    2016-08-01

    We explore the enhancement of structure-borne elastic wave energy harvesting, both numerically and experimentally, by exploiting a Gradient-Index Phononic Crystal Lens (GRIN-PCL) structure. The proposed GRIN-PCL is formed by an array of blind holes with different diameters on an aluminum plate, where the blind hole distribution is tailored to obtain a hyperbolic secant gradient profile of refractive index guided by finite-element simulations of the lowest asymmetric mode Lamb wave band diagrams. Under plane wave excitation from a line source, experimentally measured wave field validates the numerical simulation of wave focusing within the GRIN-PCL domain. A piezoelectric energy harvester disk located at the first focus of the GRIN-PCL yields an order of magnitude larger power output as compared to the baseline case of energy harvesting without the GRIN-PCL on the uniform plate counterpart.

  9. Caffeine, creatine, GRIN2A and Parkinson's disease progression.

    Science.gov (United States)

    Simon, David K; Wu, Cai; Tilley, Barbara C; Lohmann, Katja; Klein, Christine; Payami, Haydeh; Wills, Anne-Marie; Aminoff, Michael J; Bainbridge, Jacquelyn; Dewey, Richard; Hauser, Robert A; Schaake, Susen; Schneider, Jay S; Sharma, Saloni; Singer, Carlos; Tanner, Caroline M; Truong, Daniel; Wei, Peng; Wong, Pei Shieen; Yang, Tianzhong

    2017-04-15

    Caffeine is neuroprotective in animal models of Parkinson's disease (PD) and caffeine intake is inversely associated with the risk of PD. This association may be influenced by the genotype of GRIN2A, which encodes an NMDA-glutamate-receptor subunit. In two placebo-controlled studies, we detected no association of caffeine intake with the rate of clinical progression of PD, except among subjects taking creatine, for whom higher caffeine intake was associated with more rapid progression. We now have analyzed data from 420 subjects for whom DNA samples and caffeine intake data were available from a placebo-controlled study of creatine in PD. The GRIN2A genotype was not associated with the rate of clinical progression of PD in the placebo group. However, there was a 4-way interaction between GRIN2A genotype, caffeine, creatine and the time since baseline. Among subjects in the creatine group with high levels of caffeine intake, but not among those with low caffeine intake, the GRIN2A T allele was associated with more rapid progression (p=0.03). These data indicate that the deleterious interaction between caffeine and creatine with respect to rate of progression of PD is influenced by GRIN2A genotype. This example of a genetic factor interacting with environmental factors illustrates the complexity of gene-environment interactions in the progression of PD. Copyright © 2017 Elsevier B.V. All rights reserved.

  10. GrinLine identification using digital imaging and Adobe Photoshop.

    Science.gov (United States)

    Bollinger, Susan A; Brumit, Paula C; Schrader, Bruce A; Senn, David R

    2009-03-01

    The purpose of this study was to outline a method by which an antemortem photograph of a victim can be critically compared with a postmortem photograph in an effort to facilitate the identification process. Ten subjects, between 27 and 55 years old provided historical pictures of themselves exhibiting a broad smile showing anterior teeth to some extent (a grin). These photos were termed "antemortem" for the purpose of the study. A digital camera was used to take a current photo of each subject's grin. These photos represented the "postmortem" images. A single subject's "postmortem" photo set was randomly selected to be the "unknown victim." These combined data of the unknown and the 10 antemortem subjects were digitally stored and, using Adobe Photoshop software, the images were sized and oriented for comparative analysis. The goal was to devise a technique that could facilitate the accurate determination of which "antemortem" subject was the "unknown." The generation of antemortem digital overlays of the teeth visible in a grin and the comparison of those overlays to the images of the postmortem dentition is the foundation of the technique. The comparisons made using the GrinLine Identification Technique may assist medical examiners and coroners in making identifications or exclusions.

  11. Investigation of GRIN2A in common epilepsy phenotypes

    DEFF Research Database (Denmark)

    Lal, Dennis; Steinbrücker, Sandra; Schubert, Julian

    2015-01-01

    mutations by investigating patients with the two most common epilepsy syndromes: (i) idiopathic generalized epilepsy (IGE) and (ii) temporal lobe epilepsy (TLE). Whole exome sequencing data of 238 patients with IGE as well as Sanger sequencing of 84 patients with TLE were evaluated for GRIN2A sequence...

  12. Volumetric rendering and metrology of spherical gradient refractive index lens imaged by angular scan optical coherence tomography system.

    Science.gov (United States)

    Yao, Jianing; Thompson, Kevin P; Ma, Bin; Ponting, Michael; Rolland, Jannick P

    2016-08-22

    In this paper, we develop the methodology, including the refraction correction, geometrical thickness correction, coordinate transformation, and layer segmentation algorithms, for 3D rendering and metrology of a layered spherical gradient refractive index (S-GRIN) lens based on the imaging data collected by an angular scan optical coherence tomography (OCT) system. The 3D mapping and rendering enables direct 3D visualization and internal defect inspection of the lens. The metrology provides assessment of the surface geometry, the lens thickness, the radii of curvature of the internal layer interfaces, and the misalignment of the internal S-GRIN distribution with respect to the lens surface. The OCT metrology results identify the manufacturing defects, and enable targeted process development for optimizing the manufacturing parameters. The newly fabricated S-GRIN lenses show up to a 7x spherical aberration reduction that allows a significantly increased utilizable effective aperture.

  13. GRIN2B predicts attention problems among disadvantaged children.

    Science.gov (United States)

    Riva, Valentina; Battaglia, Marco; Nobile, Maria; Cattaneo, Francesca; Lazazzera, Claudio; Mascheretti, Sara; Giorda, Roberto; Mérette, Chantal; Émond, Claudia; Maziade, Michel; Marino, Cecilia

    2015-07-01

    It is well established that adversities and GRIN2B (coding an N-methyl-D-aspartate receptor subunit) are independently associated with behavioral and cognitive impairments in childhood. However, a high proportion of children exposed to adversities have good, long-term outcomes. We hypothesized that among children exposed to adversities, GRIN2B variants would predict the worst cognitive and behavioral outcomes. 6 single nucleotide polymorphisms of GRIN2B were genotyped in 625 children aged 6-11 years from an Italian community-based sample. The interacting effect of GRIN2B variants with 4 measures of adversities [low socioeconomic status (SES), preterm delivery, maternal smoking during pregnancy, and absence of breastfeeding] was investigated upon blindly assessed cognitive abilities (vocabulary, block design, digit spans of Wechsler's Intelligence Scale, and Rey complex figure) and parents-rated behavioral problems (Child Behavior Checklist/6-18). Rs2268119 × SES interaction (Hotelling's Trace = 0.07; F(12,1154) = 3.53; p = 0.00004) influenced behavior, with more attention problems among children in the 'either A/T or T/T genotype and low SES' group, compared to all other groups. This interaction effect was not significant in an independent, replication sample of 475 subjects from an Italian community-based sample. GRIN2B variants predict children with the worst outcome in attention functioning among children exposed to low SES. Our findings, if replicated, could help in the identification of children with the highest risk and may prompt cost-effective preventive/treatment strategies.

  14. A Broadband Bessel Beam Launcher Using Metamaterial Lens.

    Science.gov (United States)

    Qi, Mei Qing; Tang, Wen Xuan; Cui, Tie Jun

    2015-06-30

    An approach of generating broadband Bessel beams is presented. The broadband Bessel beams are produced by a gradient index (GRIN) metamaterial lens illuminated by broadband waveguide antenna. The metamaterial lens is constructed with multi-layered structure and each layer is composed of GRIN metamaterials. The metamaterials are designed as dielectric plates printed with metallic patterns in the center region and drilled by air holes near the edge, which operate in wide band. The metamaterial lens serves as a convertor which transforms the spherical beams emitted from feed into conical beams. The conical beams form quasi-Bessel beams in the near-field region. The aperture diameter of the GRIN lens is much larger than the operating wavelength to guarantee the transformation. In principle, this kind of metamaterial lens can produce Bessel beams at arbitrary distance by designing the refractive-index distribution. To verify the approach, we have designed, fabricated and tested a metamaterial lens. Full-wave simulation and experiment results have proved that the generated Bessel beams can be maintained in distance larger than 1 meter within a ranging from 12 GHz to 18 GHz.

  15. Modal dispersion, pulse broadening and maximum transmission rate in GRIN optical fibers encompass a central dip in the core index profile

    Science.gov (United States)

    El-Diasty, Fouad; El-Hennawi, H. A.; El-Ghandoor, H.; Soliman, Mona A.

    2013-12-01

    Intermodal and intramodal dispersions signify one of the problems in graded-index multi-mode optical fibers (GRIN) used for LAN communication systems and for sensing applications. A central index dip (depression) in the profile of core refractive-index may occur due to the CVD fabrication processes. The index dip may also be intentionally designed to broaden the fundamental mode field profile toward a plateau-like distribution, which have advantages for fiber-source connections, fiber amplifiers and self-imaging applications. Effect of core central index dip on the propagation parameters of GRIN fiber, such as intermodal dispersion, intramodal dispersion and root-mean-square broadening, is investigated. The conventional methods usually study optical signal propagation in optical fiber in terms of mode characteristics and the number of modes, but in this work multiple-beam Fizeau interferometry is proposed as an inductive but alternative methodology to afford a radial approach to determine dispersion, pulse broadening and maximum transmission rate in GRIN optical fiber having a central index dip.

  16. ALON GRIN optics for visible-MWIR applications

    Science.gov (United States)

    Nag, Nagendra; Jha, Santosh; Sastri, Suri; Goldman, Lee M.; McCarthy, Peter; Schmidt, Greg R.; Bentley, Julie L.; Moore, Duncan T.

    2016-05-01

    Surmet continuously strives to develop novel, advanced optical ceramics products for current and future defense and commercial systems. Using conventional powder processing techniques, Surmet has made substantial progress in its ability to manufacture large ALON® sensor windows, lenses, domes and transparent armor. In addition to transparency, Surmet has demonstrated the ability to incorporate other capabilities into its optical ceramic components, including: EMI shielding, heating, internal antennas and cooling channels. Working closely with the University of Rochester, Surmet has developed gradient index (GRIN) optics in ALON for use in the visible through the MWIR applications. Surmet has demonstrated the ability to tailor the refractive index of ALON® Optical Ceramic by either varying its composition or through the addition of dopants. Smooth axial and radial gradient profiles with ~0.055 change in refractive index, over depths of 1-8 mm (axial) and over 20 mm radius (radial) have been demonstrated. Initial design studies have shown that such elements provide unique capabilities. Radial gradients in particular, with their optical power contribution, provide additional degrees of freedom for color correction in broadband imaging systems. Surmet continues to mature ALON® GRIN technology along with the associated metrology. Surmet is committed to the development of its ALON® GRIN capability as well as finding insertion opportunities in novel imaging solutions for military and other commercial systems.

  17. GRIN2A polymorphisms and expression levels are associated with lead-induced neurotoxicity.

    Science.gov (United States)

    Wu, Yu; Wang, Yiqing; Wang, Miaomiao; Sun, Na; Li, Chunping

    2017-04-01

    Lead acts as an antagonist of the N-methyl-d-aspartate receptor (NMDAR). GRIN2A encodes an important subunit of NMDARs and may be a critical factor in the mechanism of lead neurotoxicity. Changes in GRIN2A expression levels or gene variants may be mechanisms of lead-induced neurotoxicity. In this study, we hypothesized that GRIN2A might contribute to lead-induced neurotoxicity. A preliminary HEK293 cell experiment was performed to analyze the association between GRIN2A expression and lead exposure. In addition, in a population-based study, serum GRIN2A levels were measured in both lead-exposed and control populations. To detect further the influence of GRIN2A gene single nucleotide polymorphisms (SNPs) in lead-induced neurotoxicity, 3 tag SNPs (rs2650429, rs6497540, and rs9302415) were genotyped in a case-control study that included 399 lead-exposed subjects and 398 controls. Lead exposure decreased GRIN2A expression levels in HEK293 cells ( p lead-free cells. Lead-exposed individuals had lower serum GRIN2A levels compared with controls ( p lead level ( p lead poisoning compared with the rs2650429 CC genotype (adjusted odds ratio = 1.42, 95% confidence interval = 1.01-2.00]. Therefore, changes in GRIN2A expression levels and variants may be important mechanisms in the development of lead-induced neurotoxicity.

  18. [Lens platform].

    Science.gov (United States)

    Łukaszewska-Smyk, Agnieszka; Kałuzny, Józef

    2010-01-01

    The lens platform defines lens structure and lens material. Evolution of lens comprises change in their shape, angulation of haptens and transition of three-piece lens into one-piece lens. The lens fall into two categories: rigid (PMMA) and soft (siliconic, acrylic, colameric). The main lens maaterials are polymers (hydrophilic and hydrophobic). The lens platform has an effect on biocompatibility, bioadhesion, stability of lens in capsule, degree of PCO evolution and sensitiveness to laser damages.

  19. Advancements in transformation optics-enabled gradient-index lens design

    Science.gov (United States)

    Campbell, Sawyer D.; Brocker, Donovan E.; Nagar, Jogender; Easum, John A.; Werner, Douglas H.; Werner, Pingjuan L.

    2015-09-01

    Transformation Optics (TO) provides the mathematical framework for representing the behavior of electromagnetic radiation in a given geometry by "transforming" it to an alternative, usually more desirable, geometry through an appropriate mapping of the constituent material parameters. Using a quasi-conformal mapping, the restrictions on the required material parameters can be relaxed allowing isotropic inhomogeneous all-dielectric materials to be employed. This approach has led to the development of a new and powerful design tool for gradient-index (GRIN) optical systems. Using TO, aspherical lenses can be transformed to simpler spherical and flat geometries or even rotationally-asymmetric shapes which result in true 3D GRIN profiles. TO can also potentially be extended to collapse an entire lens system into a representative GRIN profile thus reducing its physical dimensions while retaining the optical performance of the original system. However, dispersion effects of the constituent materials often limit the bandwidth of metamaterial and TO structures thus restricting their potential applicability. Nonetheless, with the proper pairing of GRIN profile and lens geometry to a given material system, chromatic aberrations can be minimized. To aid in the GRIN construction, we employ advanced multi-objective optimization algorithms which allow the designer to explicitly view the trade-offs between all design objectives such as RMS spot size, field-of-view (FOV), lens thickness, 𝛥𝑛, and focal drift due to chromatic aberrations. We present an overview of our TO-enabled GRIN lens design process and analysis techniques while demonstrating designs which minimize the presence of mono- and poly-chromatic aberrations and discuss their requisite material systems.

  20. Advanced gradient-index lens design tools to maximize system performance and reduce SWaP

    Science.gov (United States)

    Campbell, Sawyer D.; Nagar, Jogender; Brocker, Donovan E.; Easum, John A.; Turpin, Jeremiah P.; Werner, Douglas H.

    2016-05-01

    GRadient-INdex (GRIN) lenses have long been of interest due to their potential for providing levels of performance unachievable with traditional homogeneous lenses. While historically limited by a lack of suitable materials, rapid advancements in manufacturing techniques, including 3D printing, have recently kindled a renewed interest in GRIN optics. Further increasing the desire for GRIN devices has been the advent of Transformation Optics (TO), which provides the mathematical framework for representing the behavior of electromagnetic radiation in a given geometry by "transforming" it to an alternative, usually more desirable, geometry through an appropriate mapping of the constituent material parameters. Using TO, aspherical lenses can be transformed to simpler spherical and flat geometries or even rotationally-asymmetric shapes which result in true 3D GRIN profiles. Meanwhile, there is a critical lack of suitable design tools which can effectively evaluate the optical wave propagation through 3D GRIN profiles produced by TO. Current modeling software packages for optical lens systems also lack advanced multi-objective global optimization capability which allows the user to explicitly view the trade-offs between all design objectives such as focus quality, FOV, ▵nand focal drift due to chromatic aberrations. When coupled with advanced design methodologies such as TO, wavefront matching (WFM), and analytical achromatic GRIN theory, these tools provide a powerful framework for maximizing SWaP (Size, Weight and Power) reduction in GRIN-enabled optical systems. We provide an overview of our advanced GRIN design tools and examples which minimize the presence of mono- and polychromatic aberrations in the context of reducing SWaP.

  1. GRIN-Global: An International Project to Develop a Global Plant Genebank Information Management System

    Science.gov (United States)

    The mission of the GRIN-Global Project is to create a new, scalable version of the Germplasm Resource Information System (GRIN) to provide the world’s crop genebanks with a powerful, flexible, easy-to-use plant genetic resource (PGR) information management system. The system will help safeguard PGR ...

  2. Gradient-index ophthalmic lens design and polymer material studies

    Science.gov (United States)

    Fischer, David Joel

    Unifocal ophthalmic lenses are conventionally designed using homogeneous glass or plastic materials and aspheric surfaces. The desired power and aberration correction are provided by selection of surface shape and refractive index. This thesis studies the design of ophthalmic lenses utilizing gradient-index (GRIN) materials for both the optical power and aberration control. This is done using geometrical optical theory and ray-tracing simulations. Progressive addition lenses (PALS) are vision correction lenses with a continuous change in power used to treat presbyopia. The power variation is typically located in the lower half of the lens. Progressive addition lenses are currently made with aspheric surfaces to achieve the focal power transition and aberration control. These surfaces have at most, mirror symmetry about the vertical axis. The possible design of progressive addition lenses with GRIN materials has not been well studied. This thesis studies PALS and identifies how gradient-index materials can be used to provide both the power progression and aberration control. The optical theory for rotationally symmetric and asymmetric power additions is given. Analytical and numerical methods for calculating the index profile are used, and the results examined using ray-tracing simulations. The theory developed for ophthalmic lenses is applied to the design of GRIN axicon. This is the first GRIN axicon manufactured, and is fabricated using ion-exchanged GRIN glass. Experimental measurements of its performance are compared and found to match theoretical predictions. This demonstrates the generality of the theory developed: it may be applied to non-visual applications, and even to non-imaging applications. Realistic implementation of GRIN technology to ophthalmic application requires the fabrication of large scale refractive index gradients in polymer material systems. The methyl-methacrylate/styrene copolymer system is studied to develop an empirical model of its

  3. Effect of crystalline lens surfaces and refractive index on image quality by model simulation analysis

    Institute of Scientific and Technical Information of China (English)

    Meimei Kong; Zhishan Gao; Lei Chen; Xinhua Li

    2008-01-01

    The surfaces and refractive index of crystalline lens play an important role in the optical performance of human eye.On the basis of two eye models,which are widely applied at present,the effect of lens surfaces and its refractive index distribution on optical imaging is analyzed with the optical design software ZEMAX (Zemax Development Co.,San Diego,USA).The result shows that good image quality can be provided by the aspheric lens surfaces or (and) the gradient-index (GRIN) distribution.It has great potential in the design of intraocular lens (IOL).The eye models with an intraocular implantation are presented.

  4. I like your GRIN: Deign methods for gradient-index progressive addition lenses

    Science.gov (United States)

    Fischer, David J.; Moore, Duncan T.

    2002-12-01

    Progressive addition lenses (PALs) are vision correction lenses with a continuous change in power, used to treat the physical condition presbyopia. These lenses are currently fabricated using non-rotationally symmetric surfaces to achieve the focal power transition and aberration control. In this research, we consider the use of Gradient-Index (GRIN) designs for providing both power progression and aberration control. The use of B-Spline curves for GRIN representation is explained. Design methods and simulation results for GRIN PALs are presented. Possible uses for the design methods with other lenses, such as unifocal lenses and axicons, are also discussed.

  5. Association of GRIN1 and GRIN2A-D With schizophrenia and genetic interaction with maternal herpes simplex virus-2 infection affecting disease risk

    DEFF Research Database (Denmark)

    Demontis, Ditte; Nyegaard, Mette; Buttenschøn, Henriette Nørmølle;

    2011-01-01

    with schizophrenia and 1,500 control persons) and antibodies against maternal HSV-2 infection were measured in one of the samples (365 cases and 365 controls). Nine SNPs out of 30 in GRIN2B were significantly associated with schizophrenia. One SNP remained significant after Bonferroni correction (rs1806194, P......(nominal) ¿=¿0.0008). Significant interaction between maternal HSV-2 seropositivity and GRIN2B genetic variation in the offspring were observed for seven SNPs and two remained significant after Bonferroni correction (rs1805539, P(nominal) ¿=¿0.0001 and rs1806205, P(nominal) ¿=¿0.0008). The significant...... associations and interactions were located at the 3' region of GRIN2B suggesting that genetic variation in this part of the gene may be involved in the pathophysiology of schizophrenia. © 2011 Wiley Periodicals, Inc....

  6. Evidence that GRIN2A mutations in melanoma correlate with decreased survival

    Directory of Open Access Journals (Sweden)

    Stacey Ann N D'mello

    2014-01-01

    Full Text Available Previous whole-exome sequencing has demonstrated that melanoma tumours harbour mutations in the GRIN2A gene. GRIN2A encodes the regulatory GluN2A subunit of the glutamate-gated N-methyl-D-aspartate receptor (NMDAR, involvement of which in melanoma remains undefined. Here, we sequenced coding exons of GRIN2A in 19 low-passage melanoma cell lines derived from patients with metastatic melanoma. Potential mutation impact was evaluated in silico, including within the GluN2A crystal structure, and clinical correlations were sought. We found that of 19 metastatic melanoma tumours, four (21% carried five missense mutations in the evolutionarily conserved domains of GRIN2A; two were previously reported. Melanoma cells that carried these mutations were treatment-naïve. SIFT analysis predicted that S349F, G762E and P1132L would disrupt protein function. When modelled into the crystal structure of GluN2A, G762E was seen to potentially alter GluN1-GluN2A interactions and ligand binding, implying disruption to NMDAR functionality. Patients whose tumours carried nonsynonymous GRIN2A mutations had faster disease progression and shorter overall survival (P < 0.05. This was in contrast to the BRAF V600E mutation, found in 58% of tumours but showing no correlation with clinical outcome (P = 0.963. Although numbers of patients in this study are small, and firm conclusions about the association between GRIN2A mutations and poor clinical outcome cannot be drawn, our results highlight the high prevalence of GRIN2A mutations in metastatic melanoma and suggest for the first time that mutated NMDARs impact melanoma progression.

  7. Multimodal Afslapning

    Directory of Open Access Journals (Sweden)

    Stephen Palmer

    2012-10-01

    Full Text Available Artiklen beskriver Multimodal Relaxation Method (MRM, fremover Multimodal Afslapningsmetode, somkan anvendes i livs-, ledelses-, virksomheds-, sports- eller sundhedscoaching til at forbedre ydeevnen hos denenkelte og reducere eller håndtere stress. Inden for sports- og sundhedscoaching kan metoden anvendes til atreducere fysiske spændinger og styrke fysiologisk kontrol, fx lavere hjertefrekvens og nedsætte blodtrykket.

  8. GRIN1 mutations cause encephalopathy with infantile-onset epilepsy, and hyperkinetic and stereotyped movement disorders.

    Science.gov (United States)

    Ohba, Chihiro; Shiina, Masaaki; Tohyama, Jun; Haginoya, Kazuhiro; Lerman-Sagie, Tally; Okamoto, Nobuhiko; Blumkin, Lubov; Lev, Dorit; Mukaida, Souichi; Nozaki, Fumihito; Uematsu, Mitsugu; Onuma, Akira; Kodera, Hirofumi; Nakashima, Mitsuko; Tsurusaki, Yoshinori; Miyake, Noriko; Tanaka, Fumiaki; Kato, Mitsuhiro; Ogata, Kazuhiro; Saitsu, Hirotomo; Matsumoto, Naomichi

    2015-06-01

    Recently, de novo mutations in GRIN1 have been identified in patients with nonsyndromic intellectual disability and epileptic encephalopathy. Whole exome sequencing (WES) analysis of patients with genetically unsolved epileptic encephalopathies identified four patients with GRIN1 mutations, allowing us to investigate the phenotypic spectrum of GRIN1 mutations. Eighty-eight patients with unclassified early onset epileptic encephalopathies (EOEEs) with an age of onset stereotypic hand movements were observed in two and three patients, respectively. All the four patients exhibited only nonspecific focal and diffuse epileptiform abnormality, and never showed suppression-burst or hypsarrhythmia during infancy. A de novo mosaic mutation (c.1923G>A) with a mutant allele frequency of 16% (in DNA of blood leukocytes) was detected in one patient. Three mutations were located in the transmembrane domain (3/4, 75%), and one in the extracellular loop near transmembrane helix 1. All the mutations were predicted to impair the function of the NMDA receptor. Clinical features of de novo GRIN1 mutations include infantile involuntary movements, seizures, and hand stereotypies, suggesting that GRIN1 mutations cause encephalopathy resulting in seizures and movement disorders. Wiley Periodicals, Inc. © 2015 International League Against Epilepsy.

  9. Response to immunotherapy in a patient with Landau-Kleffner syndrome and GRIN2A mutation.

    Science.gov (United States)

    Fainberg, Nina; Harper, Amy; Tchapyjnikov, Dmitry; Mikati, Mohamad A

    2016-03-01

    Landau-Kleffner syndrome (LKS) has been demonstrated in the past to respond to immunotherapy. Recently, some cases of LKS have been shown to be secondary to glutamate receptor (GRIN2A) mutations. Whether such cases respond to immunotherapy is not known. Here, we present the case of a 3-year-old boy with LKS found to have a GRIN2A heterozygous missense mutation, whose clinical symptoms and EEG responded to a course of combination oral steroids and monthly infusions of intravenous immunoglobulin. He then relapsed after discontinuation of this therapy, and responded again after a second course of intravenous immunoglobulin. We conclude that immunotherapy should be considered as a therapeutic option in patients with LKS who are also found to harbour GRIN2A mutations.

  10. Tethered capsule OCT endomicroscopy for upper gastrointestinal tract imaging by using ball lens probe (Conference Presentation)

    Science.gov (United States)

    Dong, Jing; Gora, Michalina J.; Reddy, Rohith; Trasischker, Wolfgang; Poupart, Oriane; Lu, Weina; Carruth, Robert W.; Grant, Catriona N.; Soomro, Amna R.; Tiernan, Aubrey R.; Rosenberg, Mireille; Nishioka, Norman S.; Tearney, Guillermo J.

    2016-03-01

    While endoscopy is the most commonly used modality for diagnosing upper GI tract disease, this procedure usually requires patient sedation that increases cost and mandates its operation in specialized settings. In addition, endoscopy only visualizes tissue superfically at the macroscopic scale, which is problematic for many diseases that manifest below the surface at a microscopic scale. Our lab has previously developed technology termed tethered capsule OCT endomicroscopy (TCE) to overcome these diagnostic limitations of endoscopy. The TCE device is a swallowable capsule that contains optomechanical components that circumferentially scan the OCT beam inside the body as the pill traverses the organ via peristalsis. While we have successfully imaged ~100 patients with the TCE device, the optics of our current device have many elements and are complex, comprising a glass ferrule, optical fiber, glass spacer, GRIN lens and prism. As we scale up manufacturing of this device for clinical translation, we must decrease the cost and improve the manufacturability of the capsule's optical configuration. In this abstract, we report on the design and development of simplificed TCE optics that replace the GRIN lens-based configuration with an angle-polished ball lens design. The new optics include a single mode optical fiber, a glass spacer and an angle polished ball lens, that are all fusion spliced together. The ball lens capsule has resolutions that are comparable with those of our previous GRIN lens configuration (30µm (lateral) × 7 µm (axial)). Results in human subjects show that OCT-based TCE using the ball lens not only provides rapid, high quality microstructural images of upper GI tract, but also makes it possible to implement this technology inexpensively and on a larger scale.

  11. Deep Tissue Microscopic Imaging of the Kidney with a Gradient-Index Lens System.

    Science.gov (United States)

    Li, Xin; Yu, Weiming

    2008-04-01

    Intravital microscopy using two-photon excitation is proven to be a valuable tool for studying the kidney and associated disease processes. However, routine performance of intravital kidney imaging is limited by the fact that fluorescence signal is attenuated by the tissue and at certain tissue depth lost its strength completely. For most of the animal tissues, this finite imaging depth is limited to a few hundred microns. Currently it is not possible to non-invasively image the kidney beyond the superficial tissue layers of the cortex. This has imposed significant limitations on the animal models one can use for imaging since structure such the glomerulus is typically located below the superficial layer of the cortex that can not be imaged using a conventional fluorescence microscope. Here we report the use of a needle-like lens system based on gradient-index (GRIN) microlenses capable of transferring high quality fluorescence images of the tissue through a regular microscope objective for deep tissue imaging of the kidney. By combining this GRIN lens system with a Zeiss LSM 510 NLO microscope, we are able to extend the imaging depth for kidney tissues far beyond the few hundred microns limit. This GRIN lens imaging system provides an alternative microendoscopic imaging tool that will enhance current intravital kidney imaging techniques for studying structural and functional properties of local tissues at locations below the superficial layers of the kidney.

  12. The GRIN-Global Information Management System – Public Interface Demonstration and Input Opportunity

    Science.gov (United States)

    The GRIN-Global (GG) Information Management System, under development for the past three years, provides the world's crop genebanks and plant genetic resource (PGR) users with a powerful, flexible, easy-to-use PGR information management system. Developed jointly by the USDA Agricultural Research Ser...

  13. The GRIN-Global Information Management System – A Preview and Opportunity for Public User Input

    Science.gov (United States)

    The GRIN-Global Information Management System, under development for the past two years, will provide the world's crop genebanks and plant genetic resource (PGR) users with a powerful, flexible, easy-to-use PGR information management system. Developed jointly by the USDA Agricultural Research Servi...

  14. Focusing and Scanning through Flexible Multimode Fibers without Access to the Distal End

    CERN Document Server

    Rosen, Shamir; Katz, Ori; Silberberg, Yaron

    2015-01-01

    Multimode fibers (MMFs) are attractive ultra-thin replacements for state-of-the-art endoscopes, but the phase randomization in propagation through MMFs poses a major hurdle for imaging and focusing of light. Recently, this challenge has been addressed by pre-measuring the compensation for the fiber's complex input-output modes relations. Unfortunately, the sensitivity of this approach to fiber bending and temperature variations renders it inappropriate for many applications. Here, we demonstrate a truly endoscopic robust method for controlled in-situ focusing and scanning through a flexible uncharacterized MMF, whereby all the instrumentation is situated at the proximal end. We show that in graded-index (GRIN) fibers, light patterns at the proximal end allow retrieving information about the distal light distribution. We utilize these properties and two-photon fluorescence for robust controlled focusing through bended GRIN fibers. Our results carry potential for lensless two-photon micro-endoscopy.

  15. Multimodal stilistik

    DEFF Research Database (Denmark)

    Nørgaard, Nina

    2012-01-01

    socialsemiotiske multimodalitetsteori. Formålet med en sådan multimodal stilistik er således at udvikle et konsistent systematisk analyseapparat, der kan fange og beskrive den multimodale semiosis, der realiseres i romanen såvel som i andre typer tekst. Med nedslag i et udvalg af skandinaviske og oversatte...

  16. Identification and Characterization of Two Novel RNA Editing Sites in grin1b Transcripts of Embryonic Danio rerio

    Directory of Open Access Journals (Sweden)

    Pedro Pozo

    2012-01-01

    Full Text Available Discovering RNA editing sites in model organisms provides an insight into their adaptations in addition to finding potential sites for the regulation of neural activity and the basis of integrated models of metazoan editing with a variety of applications, including potential clinical treatments of neural dysregulation. The zebrafish, Danio rerio, is an important vertebrate model system. We focused on the grin1b gene of zebrafish due to its important function in the nervous tissue as a glutamate receptor. Using a comparative sequence-based approach, we located possible RNA editing events within the grin1b transcript. Surprisingly, sequence analysis also revealed a new editing site which was not predicted by the comparative approach. We here report the discovery of two novel RNA editing events in grin1b transcripts of embryonic zebrafish. The frequency of these editing events and their locations within the grin1b transcript are also described.

  17. ENU-mutagenesis mice with a non-synonymous mutation in Grin1 exhibit abnormal anxiety-like behaviors, impaired fear memory, and decreased acoustic startle response.

    Science.gov (United States)

    Umemori, Juzoh; Takao, Keizo; Koshimizu, Hisatsugu; Hattori, Satoko; Furuse, Tamio; Wakana, Shigeharu; Miyakawa, Tsuyoshi

    2013-05-21

    The Grin1 (glutamate receptor, ionotropic, NMDA1) gene expresses a subunit of N-methyl-D-aspartate (NMDA) receptors that is considered to play an important role in excitatory neurotransmission, synaptic plasticity, and brain development. Grin1 is a candidate susceptibility gene for neuropsychiatric disorders, including schizophrenia, bipolar disorder, and attention deficit/hyperactivity disorder (ADHD). In our previous study, we examined an N-ethyl-N-nitrosourea (ENU)-generated mutant mouse strain (Grin1(Rgsc174)/Grin1+) that has a non-synonymous mutation in Grin1. These mutant mice showed hyperactivity, increased novelty-seeking to objects, and abnormal social interactions. Therefore, Grin1(Rgsc174)/Grin1+ mice may serve as a potential animal model of neuropsychiatric disorders. However, other behavioral characteristics related to these disorders, such as working memory function and sensorimotor gating, have not been fully explored in these mutant mice. In this study, to further investigate the behavioral phenotypes of Grin1(Rgsc174)/Grin1+ mice, we subjected them to a comprehensive battery of behavioral tests. There was no significant difference in nociception between Grin1(Rgsc174)/Grin1+ and wild-type mice. The mutants did not display any abnormalities in the Porsolt forced swim and tail suspension tests. We confirmed the previous observations that the locomotor activity of these mutant mice increased in the open field and home cage activity tests. They displayed abnormal anxiety-like behaviors in the light/dark transition and the elevated plus maze tests. Both contextual and cued fear memory were severely deficient in the fear conditioning test. The mutant mice exhibited slightly impaired working memory in the eight-arm radial maze test. The startle amplitude was markedly decreased in Grin1(Rgsc174)/Grin1+ mice, whereas no significant differences between genotypes were detected in the prepulse inhibition (PPI) test. The mutant mice showed no obvious deficits

  18. Mutation screening of GRIN2B in schizophrenia and autism spectrum disorder in a Japanese population

    Science.gov (United States)

    Takasaki, Yuto; Koide, Takayoshi; Wang, Chenyao; Kimura, Hiroki; Xing, Jingrui; Kushima, Itaru; Ishizuka, Kanako; Mori, Daisuke; Sekiguchi, Mariko; Ikeda, Masashi; Aizawa, Miki; Tsurumaru, Naoko; Iwayama, Yoshimi; Yoshimi, Akira; Arioka, Yuko; Yoshida, Mami; Noma, Hiromi; Oya-Ito, Tomoko; Nakamura, Yukako; Kunimoto, Shohko; Aleksic, Branko; Uno, Yota; Okada, Takashi; Ujike, Hiroshi; Egawa, Jun; Kuwabara, Hitoshi; Someya, Toshiyuki; Yoshikawa, Takeo; Iwata, Nakao; Ozaki, Norio

    2016-01-01

    N-methyl-d-aspartate receptors (NMDARs) play a critical role in excitatory synaptic transmission and plasticity in the central nervous systems. Recent genetics studies in schizophrenia (SCZ) show that SCZ is susceptible to NMDARs and the NMDAR signaling complex. In autism spectrum disorder (ASD), several studies report dysregulation of NMDARs as a risk factor for ASD. To further examine the association between NMDARs and SCZ/ASD development, we conducted a mutation screening study of GRIN2B which encodes NR2B subunit of NMDARs, to identify rare mutations that potentially cause diseases, in SCZ and ASD patients (n = 574 and 152, respectively). This was followed by an association study in a large sample set of SCZ, ASD, and normal healthy controls (n = 4145, 381, and 4432, respectively). We identified five rare missense mutations through the mutation screening of GRIN2B. Although no statistically significant association between any single mutation and SCZ or ASD was found, one of its variant, K1292R, is found only in the patient group. To further examine the association between mutations in GRIN2B and SCZ/ASD development, a larger sample size and functional experiments are needed. PMID:27616045

  19. Association between GRIN3A gene polymorphism in Kawasaki disease and coronary artery aneurysms in Taiwanese children.

    Directory of Open Access Journals (Sweden)

    Ying-Ju Lin

    Full Text Available Kawasaki disease (KD is pediatric systemic vasculitis with the classic complication of coronary artery aneurysm (CAA. It is the leading cause of acquired cardiovascular diseases in children. Some severe cases present with multi-organ involvement or neurological dysfunction. To identify the role of the glutamate receptor, ionotropic, N-methyl-d-aspartate 3A (GRIN3A in KD, we investigated genetic variations in GRIN3A in a Taiwanese cohort of 262 KD patients (76 with and 186 without CAA complications. We used univariate and multivariate regression analyses to identify the associations between clinical characteristics and GRIN3A genetic variations in KD. According to univariate regression analysis, CAA formation in KD was significantly associated with fever duration (p < 0.0001, first Intravenous immunoglobulin (IVIG used (days after day one of fever (p < 0.0001, and the GRIN3A (rs7849782 genetic variant (p < 0.001. KD patients with GG+GC genotype showed a lower rate of developing CAA (GG+GC genotype: odds ratio = 0.26; 95% CI = 0.14-0.46. Significant associations were identified between KD with CAA complication and the GRIN3A (rs7849782 genetic variant by using multivariate regression analysis. Specifically, significant correlations were observed between KD with CAA complications and the presence of GG+GC genotypes for the GRIN3A rs7849782 single-nucleotide polymorphism (full model: odds ratio = 0.25; 95% CI = 0.14-0.46. Our results suggest that a polymorphism of the GRIN3A gene may play a role in KD pathogenesis.

  20. Lens Model

    DEFF Research Database (Denmark)

    Nash, Ulrik William

    2014-01-01

    Firms consist of people who make decisions to achieve goals. How do these people develop the expectations which underpin the choices they make? The lens model provides one answer to this question. It was developed by cognitive psychologist Egon Brunswik (1952) to illustrate his theory of probabil......Firms consist of people who make decisions to achieve goals. How do these people develop the expectations which underpin the choices they make? The lens model provides one answer to this question. It was developed by cognitive psychologist Egon Brunswik (1952) to illustrate his theory...... of probabilistic functionalism, and concerns the environment and the mind, and adaptation by the latter to the former. This entry is about the lens model, and probabilistic functionalism more broadly. Focus will mostly be on firms and their employees, but, to fully appreciate the scope, we have to keep in mind...

  1. Lens Model

    DEFF Research Database (Denmark)

    Nash, Ulrik William

    2014-01-01

    Firms consist of people who make decisions to achieve goals. How do these people develop the expectations which underpin the choices they make? The lens model provides one answer to this question. It was developed by cognitive psychologist Egon Brunswik (1952) to illustrate his theory of probabil......Firms consist of people who make decisions to achieve goals. How do these people develop the expectations which underpin the choices they make? The lens model provides one answer to this question. It was developed by cognitive psychologist Egon Brunswik (1952) to illustrate his theory...

  2. GRIN2B Mutations in West Syndrome and Intellectual Disability with Focal Epilepsy

    Science.gov (United States)

    Lemke, Johannes R; Hendrickx, Rik; Geider, Kirsten; Laube, Bodo; Schwake, Michael; Harvey, Robert J; James, Victoria M; Pepler, Alex; Steiner, Isabelle; Hörtnagel, Konstanze; Neidhardt, John; Ruf, Susanne; Wolff, Markus; Bartholdi, Deborah; Caraballo, Roberto; Platzer, Konrad; Suls, Arvid; De Jonghe, Peter; Biskup, Saskia; Weckhuysen, Sarah

    2014-01-01

    Objective To identify novel epilepsy genes using a panel approach and describe the functional consequences of mutations. Methods Using a panel approach, we screened 357 patients comprising a vast spectrum of epileptic disorders for defects in genes known to contribute to epilepsy and/or intellectual disability (ID). After detection of mutations in a novel epilepsy gene, we investigated functional effects in Xenopus laevis oocytes and screened a follow-up cohort. Results We revealed de novo mutations in GRIN2B encoding the NR2B subunit of the N-methyl-D-aspartate (NMDA) receptor in 2 individuals with West syndrome and severe developmental delay as well as 1 individual with ID and focal epilepsy. The patient with ID and focal epilepsy had a missense mutation in the extracellular glutamate-binding domain (p.Arg540His), whereas both West syndrome patients carried missense mutations within the NR2B ion channel-forming re-entrant loop (p.Asn615Ile, p.Val618Gly). Subsequent screening of 47 patients with unexplained infantile spasms did not reveal additional de novo mutations, but detected a carrier of a novel inherited GRIN2B splice site variant in close proximity (c.2011-5_2011-4delTC). Mutations p.Asn615Ile and p.Val618Gly cause a significantly reduced Mg2+ block and higher Ca2+ permeability, leading to a dramatically increased Ca2+ influx, whereas p.Arg540His caused less severe disturbance of channel function, corresponding to the milder patient phenotype. Interpretation We identified GRIN2B gain-of-function mutations as a cause of West syndrome with severe developmental delay as well as of ID with childhood onset focal epilepsy. Severely disturbed channel function corresponded to severe clinical phenotypes, underlining the important role of facilitated NMDA receptor signaling in epileptogenesis. PMID:24272827

  3. Ultra-thin rigid endoscope: Two-photon imaging through a graded-index multi-mode fiber

    CERN Document Server

    Sivankutty, Siddharth; Cossart, Rosa; Bouwmans, Géraud; Monneret, Serge; Rigneault, Hervé

    2015-01-01

    Rigid endoscopes like graded-index (GRIN) lenses are known tools in biological imaging, but it is conceptually difficult to miniaturize them. In this letter, we demonstrate an ultra-thin rigid endoscope with a diameter of only 125 microns. In addition, we identify a domain where two-photon endoscopic imaging with fs-pulse excitation is possible. We validate the ultra-thin rigid endoscope consisting of a few cm of graded-index multi-mode fiber by using it to acquire optically sectioned two-photon fluorescence endoscopic images of three-dimensional samples.

  4. Multimodal perception and simulation

    NARCIS (Netherlands)

    Werkhoven, P.J.; Erp, J.B.F. van

    2013-01-01

    This chapter discusses mechanisms of multimodal perception in the context of multimodal simulators and virtual worlds. We review some notable findings from psychophysical experiments with a focus on what we call touch-inclusive multimodal perception—that is, the sensory integration of the tactile sy

  5. A de novo loss-of-function GRIN2A mutation associated with childhood focal epilepsy and acquired epileptic aphasia

    Science.gov (United States)

    Zhang, Yujia; Kusumoto, Hirofumi; Zhang, Jin; Chen, Wenjuan; XiangWei, Wenshu; Shaulsky, Gil H.; Hu, Chun; Traynelis, Stephen F.; Yuan, Hongjie; Jiang, Yuwu

    2017-01-01

    Objective N-methyl-D-aspartate receptors (NMDAR) subunit GRIN2A/GluN2A mutations have been identified in patients with various neurological diseases, such as epilepsy and intellectual disability / developmental delay (ID/DD). In this study, we investigated the phenotype and underlying molecular mechanism of a GRIN2A missense mutation identified by next generation sequencing on idiopathic focal epilepsy using in vitro electrophysiology. Methods Genomic DNA of patients with epilepsy and ID/DD were sequenced by targeted next-generation sequencing within 300 genes related to epilepsy and ID/DD. The effects of one missense GRIN2A mutation on NMDAR function were evaluated by two-electrode voltage clamp current recordings and whole cell voltage clamp current recordings. Results We identified one de novo missense GRIN2A mutation (Asp731Asn, GluN2A(D731N)) in a child with unexplained epilepsy and DD. The D731N mutation is located in a portion of the agonist-binding domain (ABD) in the GluN2A subunit, which is the binding pocket for agonist glutamate. This residue in the ABD is conserved among vertebrate species and all other NMDAR subunits, suggesting an important role in receptor function. The proband shows developmental delay as well as EEG-confirmed seizure activity. Functional analyses reveal that the GluN2A(D731N) mutation decreases glutamate potency by over 3,000-fold, reduces amplitude of current response, shortens synaptic-like response time course, and decreases channel open probability, while enhancing sensitivity to negative allosteric modulators, including extracellular proton and zinc inhibition. The combined effects reduce NMDAR function. Significance We identified a de novo missense mutation in the GRIN2A gene in a patient with childhood focal epilepsy and acquired epileptic aphasia. The mutant decreases NMDAR activation suggesting NMDAR hypofunction may contribute to the epilepsy pathogenesis. PMID:28182669

  6. Scanless functional imaging of hippocampal networks using patterned two-photon illumination through GRIN lenses

    KAUST Repository

    Moretti, Claudio

    2016-09-12

    Patterned illumination through the phase modulation of light is increasingly recognized as a powerful tool to investigate biological tissues in combination with two-photon excitation and light-sensitive molecules. However, to date two-photon patterned illumination has only been coupled to traditional microscope objectives, thus limiting the applicability of these methods to superficial biological structures. Here, we show that phase modulation can be used to efficiently project complex two-photon light patterns, including arrays of points and large shapes, in the focal plane of graded index (GRIN) lenses. Moreover, using this approach in combination with the genetically encoded calcium indicator GCaMP6, we validate our system performing scanless functional imaging in rodent hippocampal networks in vivo ~1.2 mm below the brain surface. Our results open the way to the application of patterned illumination approaches to deep regions of highly scattering biological tissues, such as the mammalian brain.

  7. The Intersection of Multimodality and Critical Perspective: Multimodality as Subversion

    Science.gov (United States)

    Huang, Shin-ying

    2015-01-01

    This study explores the relevance of multimodality to critical media literacy. It is based on the understanding that communication is intrinsically multimodal and multimodal communication is inherently social and ideological. By analysing two English-language learners' multimodal ensembles, the study reports on how multimodality contributes to a…

  8. Grin2A expression under inhibition of miR-17 in poststroke depression rats%卒中后抑郁模型大鼠与miR-137抑制下的Grin2A表达

    Institute of Scientific and Technical Information of China (English)

    杨晓煜; 史齐; 褚秀峰; 张清琴; 张敏; 郑胜哲; 姬颖华; 路平

    2015-01-01

    背景:卒中后抑郁是脑血管病后最常见的心理行为障碍并发症,其发病机制目前尚未明确。目前研究表明, microRNA与神经发生和突触形成有关,可能在精神疾病中扮演至关重要的作用。目的:分析卒中后抑郁大鼠模型脑内和外周血中的miR-137的表达以及其对模型行为学的影响。方法:将36只大鼠分为6组,每组各6只。对照组不做任何处理,卒中后抑郁组大鼠经大脑中动脉阻塞后慢性温和刺激建立卒中后抑郁模型,agomir-137组、agomir-NC组、agomir-137+Grin2A组和agomir-137+vector组大鼠在建立卒中后抑郁模型的基础上分别给予脑室内注射agomir-137、agomir-NC、agomir-137和Grin2A过表达质粒以及agomir-137和空白质粒。结果与结论:实时定量 PCR检测显示卒中后抑郁模型大鼠脑内和外周血中 miR-137表达水平均明显低于对照组正常大鼠。行为学结果显示,在脑缺血第3周,agomir-137组大鼠垂直得分以及水平得分均显著高于agomir-NC组大鼠以及卒中后抑郁组大鼠。糖水消耗实验结果显示,在脑缺血后第2周末起,agomir-137组大鼠糖水消耗百分比即显著高于agomir-NC组大鼠以及卒中后抑郁组大鼠。进一步研究发现,miR-137可以与Grin2A的3’UTR端结合,抑制Grin2A mRNA的翻译从而下调其蛋白的表达。并且在卒中后抑郁大鼠模型的脑内过表达Grin2A基因后,miR-137抗卒中后抑郁的作用被显著减弱。提示miR-137可通过与Grin2A mRNA结合抑制其蛋白表达,从而发挥抗卒中后抑郁的作用,为卒中后抑郁提供新的临床治疗靶点。%BACKGROUND:Poststroke depression is one of the most common psychological behavior disorders after stroke and its mechanism remains unclear. Studies have suggested that microRNAs (miRNAs) involved in neurogenesis and synaptogenesis may play an important role in psychology diseases. OBJECTIVE:To observe the expression

  9. ENU-mutagenesis mice with a non-synonymous mutation in Grin1 exhibit abnormal anxiety-like behaviors, impaired fear memory, and decreased acoustic startle response

    OpenAIRE

    Umemori, Juzoh; Takao, Keizo; Koshimizu, Hisatsugu; Hattori, Satoko; Furuse, Tamio; Wakana, Shigeharu; Miyakawa, Tsuyoshi

    2013-01-01

    Background The Grin1 (glutamate receptor, ionotropic, NMDA1) gene expresses a subunit of N-methyl-D-aspartate (NMDA) receptors that is considered to play an important role in excitatory neurotransmission, synaptic plasticity, and brain development. Grin1 is a candidate susceptibility gene for neuropsychiatric disorders, including schizophrenia, bipolar disorder, and attention deficit/hyperactivity disorder (ADHD). In our previous study, we examined an N-ethyl-N-nitrosourea (ENU)-generated mut...

  10. [Association polymorphic variants of GRIN2B gene with paranoid schizophrenia and response to common neuroleptics in Russians and Tatars from Bashkortostan Republic].

    Science.gov (United States)

    Gareeva, A E; Zakirov, D F; Khusnutdinova, E K

    2013-09-01

    An analysis of the association of paranoid schizophrenia seeking with polymorphic variants of GRIN2B gene was performed in order to identify genetic risk factors of disease development and genetic markers of the response to therapy by neuroleptics in Russian and Tatar patients from Bashkortostan Republic (BB). In the course of the analysis, we revealed the following: 1) genetic markers of increased risk of developing paranoid schizophrenia in various ethnic groups, including, in Tatars, the GRIN2B* T/*Tgenotype (p = 0.003; OR = 2.33) and GRIN2B*T allele (p = 0.001; OR = 2.36), rs1805247; in Russians, the GRIN2B*T/*T genotype (p = 0.038; OR = 2.12) and GRIN2B* T allele (p = 0.028; OR = 2.03), rs1805247, genotype GRIN2B*A/*A (p = 0.042; OR = 2.12), rs1805476; 2) genetic markers of the reduced risk of developing paranoid schizophrenia; 3) genetic markers of therapy response and the risk of side effects development during neuroleptics (haloperidol) treatment in Bashkortostan. The significant interethnic diversity of genetic factors related to the risk of this disease development was noted.

  11. Contact lens in keratoconus

    Directory of Open Access Journals (Sweden)

    Varsha M Rathi

    2013-01-01

    Full Text Available Contact lenses are required for the visual improvement in patients with keratoconus. Various contact lens options, such as rigid gas permeable (RGP lenses, soft and soft toric lenses, piggy back contact lenses (PBCL, hybrid lenses and scleral lenses are availble. This article discusses about selection of a lens depending on the type of keratoconus and the fitting philosophies of various contact lenses including the starting trial lens. A Medline search was carried out for articles in the English language with the keywords keratoconus and various contact lenses such as Rose k lens, RGP lens, hybrid lens, scleral lens and PBCL.

  12. Towards Multimodal Content Representation

    CERN Document Server

    Bunt, Harry

    2009-01-01

    Multimodal interfaces, combining the use of speech, graphics, gestures, and facial expressions in input and output, promise to provide new possibilities to deal with information in more effective and efficient ways, supporting for instance: - the understanding of possibly imprecise, partial or ambiguous multimodal input; - the generation of coordinated, cohesive, and coherent multimodal presentations; - the management of multimodal interaction (e.g., task completion, adapting the interface, error prevention) by representing and exploiting models of the user, the domain, the task, the interactive context, and the media (e.g. text, audio, video). The present document is intended to support the discussion on multimodal content representation, its possible objectives and basic constraints, and how the definition of a generic representation framework for multimodal content representation may be approached. It takes into account the results of the Dagstuhl workshop, in particular those of the informal working group...

  13. Association of DRD3 and GRIN2B with impulse control and related behaviors in Parkinson's disease.

    Science.gov (United States)

    Lee, Jee-Young; Lee, Eun Kyung; Park, Sung Sup; Lim, Ji-Yeon; Kim, Hee Jin; Kim, Ji Sun; Jeon, Beom S

    2009-09-15

    We aimed to assess whether allelic variants of dopamine receptor, glutamate receptor, and serotonin transporter genes are associated with the appearance of impulse control and related behaviors (ICRB) in Parkinson's disease (PD) with dopamine replacement therapy (DRT). We surveyed ICRB in consecutive Korean patients with PD who were treated with stable DRT using modified Minnesota Impulsive Disorders Interview over a period of 4 months. In the 404 patients who completed the interview and the 559 Korean healthy normal controls, genotyping was performed for variants of the DRD3 p.S9G, DRD2 Taq1A, GRIN2B c.366C>G, c.2664C>T and c.-200T>G, and the promoter region of the serotonin transporter gene (5-HTTLPR). Behavioral abnormalities suggestive of ICRB including compulsive buying, gambling, sexual behavior and eating, and punding, were present in 14.4% of the patients. Variants of DRD2 and 5-HTTLPR were not associated with the risk of developing ICRB. However, the AA genotype of DRD3 p.S9G and the CC genotype of GRIN2B c.366C>G were more frequent in patients with ICRB than in nonaffected patients (odds ratio [OR] = 2.21, P = 0.0094; and 2.14, P = 0.0087, after adjusting for age and sex). After controlling for clinical variables in the multivariate analysis, carriage of either AA genotype of DRD3 or CC genotype of GRIN2B was identified as an independent risk factor for ICRB (adjusted OR: 2.57, P = 0.0087). Variants of DRD3 p.S9G and GRIN2B c.366C>G may be associated with the appearance of ICRB in PD.

  14. Simulation of two-dimensional adjustable liquid gradient refractive index (L-GRIN) microlens

    Science.gov (United States)

    Le, Zichun; Wu, Xiang; Sun, Yunli; Du, Ying

    2017-07-01

    In this paper, a two-dimensional liquid gradient refractive index (L-GRIN) microlens is designed which can be used in adjusting focusing direction and focal spot of light beam. Finite element method (FEM) is used to simulate the convection diffusion process happening in core inlet flow and cladding inlet flow. And the ray tracing method shows us the light beam focusing effect including the extrapolation of focal length and output beam spot size. When the flow rates of the core and cladding fluids are held the same between the internal and external, left and right, and upper and lower inlets, the focal length varied from 313 μm to 53.3 μm while the flow rate of liquids ranges from 500 pL/s to 10,000 pL/s. While the core flow rate is bigger than the cladding inlet flow rate, the light beam will focus on a light spot with a tunable size. By adjusting the ratio of cladding inlet flow rate including Qright/Qleft and Qup/Qdown, we get the adjustable two-dimensional focus direction rather than the one-dimensional focusing. In summary, by adjusting the flow rate of core inlet and cladding inlet, the focal length, output beam spot and focusing direction of the input light beam can be manipulated. We suppose this kind of flexible microlens can be used in integrated optics and lab-on-a-chip system.

  15. Critical Analysis of Multimodal Discourse

    DEFF Research Database (Denmark)

    van Leeuwen, Theo

    2013-01-01

    This is an encyclopaedia article which defines the fields of critical discourse analysis and multimodality studies, argues that within critical discourse analysis more attention should be paid to multimodality, and within multimodality to critical analysis, and ends reviewing a few examples...... of recent work in the critical analysis of multimodal discourse....

  16. Spinning pipe gas lens revisited

    CSIR Research Space (South Africa)

    Mafusire, C

    2008-01-01

    Full Text Available The graded index (GRIN-like) medium generated by gas inside a heated steel pipe when rotated about its longitudinal axis has the ability to focus a laser beam. While the effective focal length of such a system has previously been studied...

  17. Rapid cooled lens cell

    Science.gov (United States)

    Stubbs, David M.; Hsu, Ike C.

    1991-12-01

    This paper describes the optomechanical design, thermal analysis, fabrication, and test evaluation processes followed in developing a rapid cooled, infrared lens cell. Thermal analysis was the key engineering discipline exercised in the design phase. The effect of thermal stress on the lens, induced by rapid cooling of the lens cell, was investigated. Features of this lens cell that minimized the thermal stress will be discussed in a dedicated section. The results of thermal analysis on the selected lens cell design and the selection of the flow channel design in the heat exchanger will be discussed. Throughout the paper engineering drawings, illustrations, analytical results, and photographs of actual hardware are presented.

  18. GaAs/AlGaAs GRIN-SCH-SQW DBR Laser Diodes with Passive Waveguides Integrated by Compositional Disordering of the Quantum Well Using Ion Implantation

    Science.gov (United States)

    Hirata, Takaaki; Maeda, Minoru; Suehiro, Masayuki; Hosomatsu, Haruo

    1990-06-01

    GaAs/AlGaAs GRIN-SCH-SQW DBR laser diodes are fabricated by ion implantation and two-step MOVPE growth. Passive waveguides are monolithically integrated by compositional disordering of quantum well heterostructures using silicon ion implantation. Waveguide losses of partially disordered GRIN-SCH-SQW passive waveguides are measured, and propagation losses as low as 4.4 cm-1 are observed at the lasing wavelength. Stable single mode operation is obtained, and the narrowest linewidth achieved is 840 kHz. The results show that this fabrication process is useful for photonic integrated circuits.

  19. Rethinking Composing in a Digital Age: Authoring Literate Identities through Multimodal Storytelling

    Science.gov (United States)

    Vasudevan, Lalitha; Schultz, Katherine; Bateman, Jennifer

    2010-01-01

    In this article, the authors engage the theoretical lens of multimodality in rethinking the practices and processes of composing in classrooms. Specifically, they focus on how learning new composing practices led some fifth-grade students to author new literate identities--what they call authorial stances--in their classroom community. Their…

  20. ESTUDIO PRELIMINAR DE LOS POLIMORFISMOS DEL GEN GRIN-1 DEL RECEPTOR NMDA EN UNA POBLACIÓN SANA COLOMBIANA

    Directory of Open Access Journals (Sweden)

    V. Villegas

    2006-06-01

    Full Text Available Se ha encontrado que el gen GRIN-1 juega un papel fundamental en muchas funciones cerebrales y se le ha asociado con numerosas enfermedades razón por la cual ha despertado un gran interés científico el conocimiento del polimorfismo de este gen entre la población normal y enferma. Hasta el momento no han sido identificados polimorfismos que lleven a un cambio de aminoácido en la proteína y los estudios poblacionales hechos hasta la fecha sólo incluyen caucásicos, africanos americanos y asiáticos. En este trabajo se estudiaron los polimorfismos genéticos del gen GRIN-1 ubicados en la región 5’-UTR y en los exones 3, 6 y 16. Se encontró que la población estudiada se diferencia significativamente de caucásicos y no difiere significativamente de otros grupos étnicos.

  1. Contact lens in keratoconus

    OpenAIRE

    Varsha M Rathi; Preeji S Mandathara; Srikanth Dumpati

    2013-01-01

    Contact lenses are required for the visual improvement in patients with keratoconus. Various contact lens options, such as rigid gas permeable (RGP) lenses, soft and soft toric lenses, piggy back contact lenses (PBCL), hybrid lenses and scleral lenses are availble. This article discusses about selection of a lens depending on the type of keratoconus and the fitting philosophies of various contact lenses including the starting trial lens. A Medline search was carried out for articles in the En...

  2. Multimodal Resources in Transnational Adoption

    DEFF Research Database (Denmark)

    Raudaskoski, Pirkko Liisa

    The paper discusses an empirical analysis which highlights the multimodal nature of identity construction. A documentary on transnational adoption provides real life incidents as research material. The incidents involve (or from them emerge) various kinds of multimodal resources and participants...

  3. Multimodal Resources in Transnational Adoption

    DEFF Research Database (Denmark)

    Raudaskoski, Pirkko Liisa

    The paper discusses an empirical analysis which highlights the multimodal nature of identity construction. A documentary on transnational adoption provides real life incidents as research material. The incidents involve (or from them emerge) various kinds of multimodal resources and participants...

  4. Iatrogenic Lens Injuries

    Directory of Open Access Journals (Sweden)

    Ümit Kamış

    2012-12-01

    Full Text Available During intraocular surgery, undesired damages of various etiology may occur in adjacent tissues. One of these tissues is the crystalline lens, which may be traumatized both in anterior segment and posterior segment surgeries, and when damaged, it usually causes marked decrease in visual acuity. The leading causes of iatrogenic lens injuries are intravitreal injection, laser iridotomy, phakic intraocular lens implantation, anterior chamber paracentesis, and vitreoretinal surgery. When crystalline lens damage occurs, its negative effect on visual function may be eliminated by performing cataract surgery intraoperatively or in elective conditions. (Turk J Ophthalmol 2012; 42: Supplement 27-30

  5. Multimodal sequence learning.

    Science.gov (United States)

    Kemény, Ferenc; Meier, Beat

    2016-02-01

    While sequence learning research models complex phenomena, previous studies have mostly focused on unimodal sequences. The goal of the current experiment is to put implicit sequence learning into a multimodal context: to test whether it can operate across different modalities. We used the Task Sequence Learning paradigm to test whether sequence learning varies across modalities, and whether participants are able to learn multimodal sequences. Our results show that implicit sequence learning is very similar regardless of the source modality. However, the presence of correlated task and response sequences was required for learning to take place. The experiment provides new evidence for implicit sequence learning of abstract conceptual representations. In general, the results suggest that correlated sequences are necessary for implicit sequence learning to occur. Moreover, they show that elements from different modalities can be automatically integrated into one unitary multimodal sequence.

  6. Multimodal Processes Rescheduling

    DEFF Research Database (Denmark)

    Bocewicz, Grzegorz; Banaszak, Zbigniew A.; Nielsen, Peter

    2013-01-01

    Cyclic scheduling problems concerning multimodal processes are usually observed in FMSs producing multi-type parts where the Automated Guided Vehicles System (AGVS) plays a role of a material handling system. Schedulability analysis of concurrently flowing cyclic processes (SCCP) exe-cuted in the......Cyclic scheduling problems concerning multimodal processes are usually observed in FMSs producing multi-type parts where the Automated Guided Vehicles System (AGVS) plays a role of a material handling system. Schedulability analysis of concurrently flowing cyclic processes (SCCP) exe...

  7. Superlensing Microscope Objective Lens

    CERN Document Server

    Yan, Bing; Parker, Alan; Lai, Yukun; Thomas, John; Yue, Liyang; Monks, James

    2016-01-01

    Conventional microscope objective lenses are diffraction limited, which means that they cannot resolve features smaller than half the illumination wavelength. Under white light illumination, such resolution limit is about 250-300 nm for an ordinary microscope. In this paper, we demonstrate a new superlensing objective lens which has a resolution of about 100 nm, offering at least two times resolution improvement over conventional objectives in resolution. This is achieved by integrating a conventional microscope objective lens with a superlensing microsphere lens using a 3D printed lens adaptor. The new objective lens was used for label-free super-resolution imaging of 100 nm-sized engineering and biological samples, including a Blu-ray disc sample, semiconductor chip and adenoviruses. Our work creates a solid base for developing a commercially-viable superlens prototype, which has potential to transform the field of optical microscopy and imaging.

  8. Multimode geodesic branching components

    Science.gov (United States)

    Schulz, D.; Voges, E.

    1983-01-01

    Geodesic branching components are investigated for multimode guided wave optics. Geodesic structures with particular properties, e.g. focussing star couplers, are derived by a synthesis technique based on a theorem of Toraldo di Francia. Experimentally, the geodesic surfaces are printed on acrylic glass and are spin-coated with organic film waveguides.

  9. Multimodal emergens via musik

    DEFF Research Database (Denmark)

    Bonde, Anders

    2010-01-01

    I denne artikel præsenteres og argumenteres for en værkanalytisk indfaldsvinkel i forhold til det at undersøge multimodal betydningsdannelse i audiovisuelle medieprodukter såsom reklamefilm og dokumentarfilm, hvor flere forskellige modaliteter eller semiotiske ressourcer samvirker. Som teoretisk...

  10. Multimodal Strategies of Theorization

    DEFF Research Database (Denmark)

    Cartel, Melodie; Colombero, Sylvain; Boxenbaum, Eva

    This paper examines the role of multimodal strategies in processes of theorization. Empirically, we investigate the theorization process of a highly disruptive innovation in the history of architecture: reinforced concrete. Relying on archival data from a dominant French architectural journal fro...

  11. Multimodal Strategies of Theorization

    DEFF Research Database (Denmark)

    Cartel, Melodie; Colombero, Sylvain; Boxenbaum, Eva

    This paper examines the role of multimodal strategies in processes of theorization. Empirically, we investigate the theorization process of a highly disruptive innovation in the history of architecture: reinforced concrete. Relying on archival data from a dominant French architectural journal from...... with well-known rhetorical strategies and develop a process model of theorization....

  12. Modeling Multimodal Stratification

    DEFF Research Database (Denmark)

    Boeriis, Morten

    2017-01-01

    This article discusses one of the core axioms of social semiotic theory, namely stratification, in the light of developments in multimodality in recent years. The discussion takes a point of departure in the approaches to stratification taken by Hjelmslev, Halliday, and Kress and van Leeuwen...

  13. Comprendre le référendum d’autodétermination monténégrin

    OpenAIRE

    2007-01-01

    Du référendum d’autodétermination monténégrin de mars 1992 à celui de mai 2006, l’opinion monténégrine a évolué en faveur de l’option indépendantiste. Cet article propose d’analyser cette évolution par une mise en perspective combinant les «clivages géonationalistes» structurants de la scène politique au Monténégro, du XIXe siècle à nos jours, et leurs multiples articulations en fonction du contexte sociopolitique des quinze dernières années. Ces multiples combinaisons permettent d’interpréte...

  14. Unitary lens semiconductor device

    Science.gov (United States)

    Lear, Kevin L.

    1997-01-01

    A unitary lens semiconductor device and method. The unitary lens semiconductor device is provided with at least one semiconductor layer having a composition varying in the growth direction for unitarily forming one or more lenses in the semiconductor layer. Unitary lens semiconductor devices may be formed as light-processing devices such as microlenses, and as light-active devices such as light-emitting diodes, photodetectors, resonant-cavity light-emitting diodes, vertical-cavity surface-emitting lasers, and resonant cavity photodetectors.

  15. Intraocular lens fabrication

    Energy Technology Data Exchange (ETDEWEB)

    Salazar, M.A.; Foreman, L.R.

    1997-07-08

    This invention describes a method for fabricating an intraocular lens made from clear Teflon{trademark}, Mylar{trademark}, or other thermoplastic material having a thickness of about 0.025 millimeters. These plastic materials are thermoformable and biocompatable with the human eye. The two shaped lenses are bonded together with a variety of procedures which may include thermosetting and solvent based adhesives, laser and impulse welding, and ultrasonic bonding. The fill tube, which is used to inject a refractive filling material is formed with the lens so as not to damage the lens shape. A hypodermic tube may be included inside the fill tube. 13 figs.

  16. Intraocular lens fabrication

    Energy Technology Data Exchange (ETDEWEB)

    Salazar, Mike A. (Albuquerque, NM); Foreman, Larry R. (Los Alamos, NM)

    1997-01-01

    This invention describes a method for fabricating an intraocular lens made rom clear Teflon.TM., Mylar.TM., or other thermoplastic material having a thickness of about 0.025 millimeters. These plastic materials are thermoformable and biocompatable with the human eye. The two shaped lenses are bonded together with a variety of procedures which may include thermosetting and solvent based adhesives, laser and impulse welding, and ultrasonic bonding. The fill tube, which is used to inject a refractive filling material is formed with the lens so as not to damage the lens shape. A hypodermic tube may be included inside the fill tube.

  17. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... Lens-Related Eye Infections Mar 01, 2017 New Technology Helps the Legally Blind Be More Independent Oct ... easy answer, and neither one considers long-term impacts. Phakic Intraocular Lenses for Nearsightedness FEB 27, 2017 ...

  18. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... lenses without a prescription in the United States. All contact lenses are medical devices that require a ... no such thing as a "one size fits all" contact lens. Lenses that are not properly fitted ...

  19. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... wear any kind of contact lens. In Butler's case, the lenses caused an infection and left her with a corneal abrasion. ... Studies Look at Effects of Marijuana on Vision FEB ...

  20. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... sell contacts without a prescription are breaking the law, and may be fined $11,000 per violation. " ... wear any kind of contact lens. In Butler's case, the lenses caused an infection and left her ...

  1. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... not require the same level of care or consideration as a standard contact lens because they can ... Us About the Academy Jobs at the Academy Financial Relationships with Industry Medical Disclaimer Privacy Policy Terms ...

  2. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... be purchased over-the-counter or on the Internet," says Thomas Steinemann, MD, professor of ophthalmology at ... ask for a prescription. There is no such thing as a "one size fits all" contact lens. ...

  3. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... Vision and Daily Eye Drops After One Use Facts About Colored Contacts and Halloween Safety Colored Contact Lens Facts Over-the-Counter Costume Contacts May Contain Chemicals ...

  4. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... not require the same level of care or consideration as a standard contact lens because they can ... 2016 More Eye Health News Studies Look at Effects of Marijuana on Vision FEB 28, 2017 By ...

  5. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... not require the same level of care or consideration as a standard contact lens because they can ... sell contacts without a prescription are breaking the law, and may be fined $11,000 per violation. " ...

  6. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... Contact Lens-Related Eye Infections Mar 01, 2017 New Technology Helps the Legally Blind Be More Independent ... Worse? May 16, 2016 More Eye Health News New Dry Eye Treatment is a Tear-Jerker JUL ...

  7. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... glow-in-the-dark lizard lenses, costume contacts can certainly add a spooky, eye-popping touch. But ... consideration as a standard contact lens because they can be purchased over-the-counter or on the ...

  8. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... One Use Facts About Colored Contacts and Halloween Safety Colored Contact Lens Facts Over-the-Counter Costume ... use of colored contact lenses , from the U.S. Food and Drug Administration (FDA). Are the colored lenses ...

  9. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... Healthy Contact Lens Use May 31, 2016 Is El Niño Making Your Allergies Worse? May 16, 2016 ... Number: * Email: * Enter code: * Message: Thank you Your feedback has been sent.

  10. Genome-wide gene-environment study identifies glutamate receptor gene GRIN2A as a Parkinson's disease modifier gene via interaction with coffee.

    Science.gov (United States)

    Hamza, Taye H; Chen, Honglei; Hill-Burns, Erin M; Rhodes, Shannon L; Montimurro, Jennifer; Kay, Denise M; Tenesa, Albert; Kusel, Victoria I; Sheehan, Patricia; Eaaswarkhanth, Muthukrishnan; Yearout, Dora; Samii, Ali; Roberts, John W; Agarwal, Pinky; Bordelon, Yvette; Park, Yikyung; Wang, Liyong; Gao, Jianjun; Vance, Jeffery M; Kendler, Kenneth S; Bacanu, Silviu-Alin; Scott, William K; Ritz, Beate; Nutt, John; Factor, Stewart A; Zabetian, Cyrus P; Payami, Haydeh

    2011-08-01

    Our aim was to identify genes that influence the inverse association of coffee with the risk of developing Parkinson's disease (PD). We used genome-wide genotype data and lifetime caffeinated-coffee-consumption data on 1,458 persons with PD and 931 without PD from the NeuroGenetics Research Consortium (NGRC), and we performed a genome-wide association and interaction study (GWAIS), testing each SNP's main-effect plus its interaction with coffee, adjusting for sex, age, and two principal components. We then stratified subjects as heavy or light coffee-drinkers and performed genome-wide association study (GWAS) in each group. We replicated the most significant SNP. Finally, we imputed the NGRC dataset, increasing genomic coverage to examine the region of interest in detail. The primary analyses (GWAIS, GWAS, Replication) were performed using genotyped data. In GWAIS, the most significant signal came from rs4998386 and the neighboring SNPs in GRIN2A. GRIN2A encodes an NMDA-glutamate-receptor subunit and regulates excitatory neurotransmission in the brain. Achieving P(2df) = 10(-6), GRIN2A surpassed all known PD susceptibility genes in significance in the GWAIS. In stratified GWAS, the GRIN2A signal was present in heavy coffee-drinkers (OR = 0.43; P = 6×10(-7)) but not in light coffee-drinkers. The a priori Replication hypothesis that "Among heavy coffee-drinkers, rs4998386_T carriers have lower PD risk than rs4998386_CC carriers" was confirmed: OR(Replication) = 0.59, P(Replication) = 10(-3); OR(Pooled) = 0.51, P(Pooled) = 7×10(-8). Compared to light coffee-drinkers with rs4998386_CC genotype, heavy coffee-drinkers with rs4998386_CC genotype had 18% lower risk (P = 3×10(-3)), whereas heavy coffee-drinkers with rs4998386_TC genotype had 59% lower risk (P = 6×10(-13)). Imputation revealed a block of SNPs that achieved P(2df)coffee-drinkers. This study is proof of concept that inclusion of environmental factors can help identify

  11. Genome-Wide Gene-Environment Study Identifies Glutamate Receptor Gene GRIN2A as a Parkinson's Disease Modifier Gene via Interaction with Coffee

    Science.gov (United States)

    Hamza, Taye H.; Chen, Honglei; Hill-Burns, Erin M.; Rhodes, Shannon L.; Montimurro, Jennifer; Kay, Denise M.; Tenesa, Albert; Kusel, Victoria I.; Sheehan, Patricia; Eaaswarkhanth, Muthukrishnan; Yearout, Dora; Samii, Ali; Roberts, John W.; Agarwal, Pinky; Bordelon, Yvette; Park, Yikyung; Wang, Liyong; Gao, Jianjun; Vance, Jeffery M.; Kendler, Kenneth S.; Bacanu, Silviu-Alin; Scott, William K.; Ritz, Beate; Nutt, John; Factor, Stewart A.; Zabetian, Cyrus P.; Payami, Haydeh

    2011-01-01

    Our aim was to identify genes that influence the inverse association of coffee with the risk of developing Parkinson's disease (PD). We used genome-wide genotype data and lifetime caffeinated-coffee-consumption data on 1,458 persons with PD and 931 without PD from the NeuroGenetics Research Consortium (NGRC), and we performed a genome-wide association and interaction study (GWAIS), testing each SNP's main-effect plus its interaction with coffee, adjusting for sex, age, and two principal components. We then stratified subjects as heavy or light coffee-drinkers and performed genome-wide association study (GWAS) in each group. We replicated the most significant SNP. Finally, we imputed the NGRC dataset, increasing genomic coverage to examine the region of interest in detail. The primary analyses (GWAIS, GWAS, Replication) were performed using genotyped data. In GWAIS, the most significant signal came from rs4998386 and the neighboring SNPs in GRIN2A. GRIN2A encodes an NMDA-glutamate-receptor subunit and regulates excitatory neurotransmission in the brain. Achieving P2df = 10−6, GRIN2A surpassed all known PD susceptibility genes in significance in the GWAIS. In stratified GWAS, the GRIN2A signal was present in heavy coffee-drinkers (OR = 0.43; P = 6×10−7) but not in light coffee-drinkers. The a priori Replication hypothesis that “Among heavy coffee-drinkers, rs4998386_T carriers have lower PD risk than rs4998386_CC carriers” was confirmed: ORReplication = 0.59, PReplication = 10−3; ORPooled = 0.51, PPooled = 7×10−8. Compared to light coffee-drinkers with rs4998386_CC genotype, heavy coffee-drinkers with rs4998386_CC genotype had 18% lower risk (P = 3×10−3), whereas heavy coffee-drinkers with rs4998386_TC genotype had 59% lower risk (P = 6×10−13). Imputation revealed a block of SNPs that achieved P2dfcoffee-drinkers. This study is proof of concept that inclusion of environmental factors can help identify genes that

  12. Multimodal eye recognition

    Science.gov (United States)

    Zhou, Zhi; Du, Yingzi; Thomas, N. L.; Delp, Edward J., III

    2010-04-01

    Multimodal biometrics use more than one means of biometric identification to achieve higher recognition accuracy, since sometimes a unimodal biometric is not good enough used to do identification and classification. In this paper, we proposed a multimodal eye recognition system, which can obtain both iris and sclera patterns from one color eye image. Gabor filter and 1-D Log-Gabor filter algorithms have been applied as the iris recognition algorithms. In sclera recognition, we introduced automatic sclera segmentation, sclera pattern enhancement, sclera pattern template generation, and sclera pattern matching. We applied kernelbased matching score fusion to improve the performance of the eye recognition system. The experimental results show that the proposed eye recognition method can achieve better performance compared to unimodal biometric identification, and the accuracy of our proposed kernel-based matching score fusion method is higher than two classic linear matching score fusion methods: Principal Component Analysis (PCA) and Linear Discriminant Analysis (LDA).

  13. Programmable Multimode Quantum Networks

    CERN Document Server

    Armstrong, Seiji; Janousek, Jiri; Hage, Boris; Treps, Nicolas; Lam, Ping Koy; Bachor, Hans-A

    2012-01-01

    Entanglement between large numbers of quantum modes is the quintessential resource for quantum information processing and future applications such as the quantum internet. Conventionally the generation of multimode entanglement in optics requires complex layouts of beam-splitters and phase shifters in order to transform the input modes in to entangled modes. These networks need substantial modification for every new set of entangled modes to be generated. Further, the complexity grows rapidly with the number of entangled modes as the number of detectors, phase locks and optical components needs to be increased. Here we report on the highly efficient and versatile generation of various multimode entangled states within one optical beam. By defining our modes to be combinations of different spatial regions of the beam, we may use just one pair of multi-pixel detectors and one local oscillator to measure an orthogonal set of modes. The transformation of this set into a desired set of entangled modes is calculate...

  14. Candidate-Gene Screening and Association Analysis at the Autism-Susceptibility Locus on Chromosome 16p: Evidence of Association at GRIN2A and ABAT

    Science.gov (United States)

    Barnby, Gabrielle; Abbott, Aaron; Sykes, Nuala; Morris, Andrew; Weeks, Daniel E.; Mott, Richard; Lamb, Janine; Bailey, Anthony J.; Monaco, Anthony P.

    2005-01-01

    Autism is a highly heritable neurodevelopmental disorder whose underlying genetic causes have yet to be identified. To date, there have been eight genome screens for autism, two of which identified a putative susceptibility locus on chromosome 16p. In the present study, 10 positional candidate genes that map to 16p11-13 were examined for coding variants: A2BP1, ABAT, BFAR, CREBBP, EMP2, GRIN2A, MRTF-B, SSTR5, TBX6, and UBN1. Screening of all coding and regulatory regions by denaturing high-performance liquid chromatography identified seven nonsynonymous changes. Five of these mutations were found to cosegregate with autism, but the mutations are not predicted to have deleterious effects on protein structure and are unlikely to represent significant etiological variants. Selected variants from candidate genes were genotyped in the entire International Molecular Genetics Study of Autism Consortium collection of 239 multiplex families and were tested for association with autism by use of the pedigree disequilibrium test. Additionally, genotype frequencies were compared between 239 unrelated affected individuals and 192 controls. Patterns of linkage disequilibrium were investigated, and the transmission of haplotypes across candidate genes was tested for association. Evidence of single-marker association was found for variants in ABAT, CREBBP, and GRIN2A. Within these genes, 12 single-nucleotide polymorphisms (SNPs) were subsequently genotyped in 91 autism trios (one affected individual and two unaffected parents), and the association was replicated within GRIN2A (Fisher's exact test, P<.0001). Logistic regression analysis of SNP data across GRIN2A and ABAT showed a trend toward haplotypic differences between cases and controls. PMID:15830322

  15. Simplified Multimodal Biometric Identification

    Directory of Open Access Journals (Sweden)

    Abhijit Shete

    2014-03-01

    Full Text Available Multibiometric systems are expected to be more reliable than unimodal biometric systems for personal identification due to the presence of multiple, fairly independent pieces of evidence e.g. Unique Identification Project "Aadhaar" of Government of India. In this paper, we present a novel wavelet based technique to perform fusion at the feature level and score level by considering two biometric modalities, face and fingerprint. The results indicate that the proposed technique can lead to substantial improvement in multimodal matching performance. The proposed technique is simple because of no preprocessing of raw biometric traits as well as no feature and score normalization.

  16. Multimodality of Learning Through Anchored Instruction

    Science.gov (United States)

    Love, Mary Susan

    2004-01-01

    Multimodality of learning results from the intertextual relationship between multimodal design and other meaning-making modes. Meaning making is becoming more multimodal because language is continually reshaped by new forms of communication media. This article examines anchored instruction from a multimodal perspective. The first section includes…

  17. Learning multimodal latent attributes.

    Science.gov (United States)

    Fu, Yanwei; Hospedales, Timothy M; Xiang, Tao; Gong, Shaogang

    2014-02-01

    The rapid development of social media sharing has created a huge demand for automatic media classification and annotation techniques. Attribute learning has emerged as a promising paradigm for bridging the semantic gap and addressing data sparsity via transferring attribute knowledge in object recognition and relatively simple action classification. In this paper, we address the task of attribute learning for understanding multimedia data with sparse and incomplete labels. In particular, we focus on videos of social group activities, which are particularly challenging and topical examples of this task because of their multimodal content and complex and unstructured nature relative to the density of annotations. To solve this problem, we 1) introduce a concept of semilatent attribute space, expressing user-defined and latent attributes in a unified framework, and 2) propose a novel scalable probabilistic topic model for learning multimodal semilatent attributes, which dramatically reduces requirements for an exhaustive accurate attribute ontology and expensive annotation effort. We show that our framework is able to exploit latent attributes to outperform contemporary approaches for addressing a variety of realistic multimedia sparse data learning tasks including: multitask learning, learning with label noise, N-shot transfer learning, and importantly zero-shot learning.

  18. GRIN2B Gene and Associated Brain Cortical White Matter Changes in Bipolar Disorder: A Preliminary Combined Platform Investigation

    Directory of Open Access Journals (Sweden)

    Carissa Nadia Kuswanto

    2013-01-01

    Full Text Available Abnormalities in glutamate signaling and glutamate toxicity are thought to be important in the pathophysiology of bipolar disorder (BD. Whilst previous studies have found brain white matter changes in BD, there is paucity of data about how glutamatergic genes affect brain white matter integrity in BD. Based on extant neuroimaging data, we hypothesized that GRIN2B risk allele is associated with reductions of brain white matter integrity in the frontal, parietal, temporal, and occipital regions and cingulate gyrus in BD. Fourteen patients with BD and 22 healthy controls matched in terms of age, gender and handedness were genotyped using blood samples and underwent diffusion tensor imaging. Compared to G allele, brain FA values were significantly lower in BD patients with risk T allele in left frontal region (P=0.001, right frontal region (P=0.002, left parietal region (P=0.001, left occipital region (P=0.001, right occipital region (P<0.001, and left cingulate gyrus (P=0.001. Further elucidation of the interactions between different glutamate genes and their relationships with such structural, functional brain substrates will enhance our understanding of the link between dysregulated glutamatergic neurotransmission and neuroimaging endophenotypes in BD.

  19. Thin Lens Ray Tracing.

    Science.gov (United States)

    Gatland, Ian R.

    2002-01-01

    Proposes a ray tracing approach to thin lens analysis based on a vector form of Snell's law for paraxial rays as an alternative to the usual approach in introductory physics courses. The ray tracing approach accommodates skew rays and thus provides a complete analysis. (Author/KHR)

  20. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... Lens Use May 31, 2016 Is El Niño Making Your Allergies Worse? May 16, 2016 More Eye ... EyeSmart Embed EyeSmart videos on your website Promotional materials for eye health observances EyeSmart resources are also ...

  1. Using multiple metaphors and multimodalities as a semiotic resource when teaching year 2 students computational strategies

    Science.gov (United States)

    Mildenhall, Paula; Sherriff, Barbara

    2017-06-01

    Recent research indicates that using multimodal learning experiences can be effective in teaching mathematics. Using a social semiotic lens within a participationist framework, this paper reports on a professional learning collaboration with a primary school teacher designed to explore the use of metaphors and modalities in mathematics instruction. This video case study was conducted in a year 2 classroom over two terms, with the focus on building children's understanding of computational strategies. The findings revealed that the teacher was able to successfully plan both multimodal and multiple metaphor learning experiences that acted as semiotic resources to support the children's understanding of abstract mathematics. The study also led to implications for teaching when using multiple metaphors and multimodalities.

  2. Multimodal responsive action

    DEFF Research Database (Denmark)

    Oshima, Sae

    While a first pair part projects a limited set of second pair parts to be provided next, responders select different types and formats for second pair parts to assemble activities (Schegloff 2007). Accordingly, various ways of shaping responses have been extensively studied (e.g. Pomerantz 1984......; Raymond 2003; Schegloff and Lerner 2009), including those with multimodal actions (e.g. Olsher 2004; Fasulo & Monzoni 2009). Some responsive actions can also be completed with bodily behavior alone, such as: when an agreement display is achieved by using only nonvocal actions (Jarmon 1996), when...... both verbal and body-behavioral elements. This paper explores one such situation in professional-client interaction, during the event of evaluating a service outcome in a haircutting session. In general, a haircutting session is brought to its closure through the service-assessment sequence, in which...

  3. Robustness of multimodal processes itineraries

    DEFF Research Database (Denmark)

    Bocewicz, G.; Banaszak, Z.; Nielsen, Izabela Ewa

    2013-01-01

    This paper concerns multimodal transport systems (MTS) represented by a supernetworks in which several unimodal networks are connected by transfer links and focuses on the scheduling problems encountered in these systems. Assuming unimodal networks are modeled as cyclic lines, i.e. the routes det...... of multimodal processes driven itinerary planning problem is our main contribution. Illustrative examples providing alternative itineraries in some cases of MTS malfunction are presented....

  4. [The association between the GRIN2B gene and verbal fluency and impairment of abstract thinking in schizophrenia].

    Science.gov (United States)

    Alfimova, M V; Golimbet, V E; Korovaitseva, G I; Abramova, L I; Lezheiko, T V; Aksenova, E V

    2016-01-01

    Цель исследования. Исследование было направлено на поиск ассоциаций между геном GRIN2B и признаками нарушения мышления и речи при шизофрении, в основе которых может лежать снижение доступа к ментальному лексикону. Материал и методы. В группе из 552 пациентов с расстройствами шизофренического спектра определяли связи между полиморфизмом rs7301328 в гене GRIN2B и семантической вербальной беглостью и пятью симптомами нарушений мышления и речи, входящими в шкалу позитивных и негативных симптомов (PANSS). Результаты и обсуждение. Обнаружена ассоциация гена GRIN2B как с вербальной беглостью (p=0,013), так и нарушением абстрактного мышления (p=0,012). При этом не выявлено опосредующей роли вербальной беглости в ассоциации между геном и нарушением мышления. Результаты позволяют предположить, что ген GRIN2B оказывает модифицирующее действие на лингвистические процессы, обеспечивающие извлечение информации из ментального лексикона на основе семантических признаков, и, кроме того, вносит вклад в вариативность клинически выраженных нарушений абстрактного мышления у больных шизофренией. При этом гете

  5. Analysis of variations in the glutamate receptor, N-methyl D-aspartate 2A (GRIN2A gene reveals their relative importance as genetic susceptibility factors for heroin addiction.

    Directory of Open Access Journals (Sweden)

    Bin Zhao

    Full Text Available The glutamate receptor, N-methyl D-aspartate 2A (GRIN2A gene that encodes the 2A subunit of the N-methyl D-aspartate (NMDA receptor was recently shown to be involved in the development of opiate addiction. Genetic polymorphisms in GRIN2A have a plausible role in modulating the risk of heroin addiction. An association of GRIN2A single-nucleotide polymorphisms (SNPs with heroin addiction was found earlier in African Americans. To identify markers that contribute to the genetic susceptibility to heroin addiction, we examined the potential association between heroin addiction and forty polymorphisms of the GRIN2A gene using the MassARRAY system and GeneScan in this study. The frequency of the (GT26 repeats (rs3219790 in the heroin addiction group was significantly higher than that in the control group (χ(2 = 5.360, P = 0.021. The allele frequencies of three polymorphisms (rs1102972, rs1650420, and rs3104703 in intron 3 were strongly associated with heroin addiction (P<0.001, 0.0002, and <0.001, after Bonferroni correction. Three additional SNPs from the same intron (rs1071502, rs6497730, and rs1070487 had nominally significant P values for association (P<0.05, but did not pass the threshold value. Haplotype analysis revealed that the G-C-T-C-C-T-A (block 6 and T-T (block 10 haplotypes of the GRIN2A gene displayed a protective effect (P = <0.001 and 0.003. These findings point to a role for GRIN2A polymorphisms in heroin addiction among the Han Chinese from Shaanxi province, and may be informative for future genetic or neurobiological studies on heroin addiction.

  6. Wood lens design philosophy based on a binary additive manufacturing technique

    Science.gov (United States)

    Marasco, Peter L.; Bailey, Christopher

    2016-04-01

    Using additive manufacturing techniques in optical engineering to construct a gradient index (GRIN) optic may overcome a number of limitations of GRIN technology. Such techniques are maturing quickly, yielding additional design degrees of freedom for the engineer. How best to employ these degrees of freedom is not completely clear at this time. This paper describes a preliminary design philosophy, including assumptions, pertaining to a particular printing technique for GRIN optics. It includes an analysis based on simulation and initial component measurement.

  7. LASER INDUCED THERMAL LENS EFFECT

    Institute of Scientific and Technical Information of China (English)

    沈俊; 黄孟才; 江景云; 施教芳

    1991-01-01

    The thermal lens effect has emerged in recent years as a novel ,highly sensitive tool for the study of the very weak molecular absorption of light energy,This paper discusses the theory and technique of the thermal lens measurement.Some opplications of the thermal lens measurement are described.A mode-mismatched dual-beam thermal lens experimental arragement with a modulated probe beam ,designed by the authors.for trace analysis is presented,and its detection limit was found to be 4.1×10-7 for Cu(Ⅱ) in ethanol and 80 mW excitation power.

  8. Rotman Lens-Based Circular Array for Generating Five-mode OAM Radio Beams

    Science.gov (United States)

    Bai, Xu-Dong; Liang, Xian-Ling; Li, Jian-Ping; Wang, Kun; Geng, Jun-Ping; Jin, Rong-Hong

    2016-06-01

    Recently, vortex beam carrying orbital angular momentum (OAM) for radio communications has attracted much attention for its potential of transmitting multiple signals simultaneously at the same frequency, which can be used to increase the channel capacity. However, most of the methods for getting multi-mode OAM radio beams remain up to now mainly at simulation level, since their implementations are of complicated structure and very high cost. This paper provides an effective design of generating five-mode OAM radio beams by using the Rotman lens-fed antenna array. The Rotman lens is a viable beamforming approach instead of electronically scanned arrays for its low cost and the ease of implementation. The lens-fed array employs a two-layer structure for size reduction, and the lens body and the antenna array are segregated by a common ground plane to eliminate spurious radiation and thus improve the performance of the OAM beams. The measured results coincide with the simulated ones, which verified the effectiveness of the proposed design for generating multi-mode OAM beams.

  9. Vector-Resonance-Multimode Instability

    Science.gov (United States)

    Sergeyev, S. V.; Kbashi, H.; Tarasov, N.; Loiko, Yu.; Kolpakov, S. A.

    2017-01-01

    The modulation and multimode instabilities are the main mechanisms which drive spontaneous spatial and temporal pattern formation in a vast number of nonlinear systems ranging from biology to laser physics. Using an Er-doped fiber laser as a test bed, here for the first time we demonstrate both experimentally and theoretically a new type of a low-threshold vector-resonance-multimode instability which inherits features of multimode and modulation instabilities. The same as for the multimode instability, a large number of longitudinal modes can be excited without mode synchronization. To enable modulation instability, we modulate the state of polarization of the lasing signal with the period of the beat length by an adjustment of the in-cavity birefringence and the state of polarization of the pump wave. As a result, we show the regime's tunability from complex oscillatory to periodic with longitudinal mode synchronization in the case of resonance matching between the beat and cavity lengths. Apart from the interest in laser physics for unlocking the tunability and stability of dynamic regimes, the proposed mechanism of the vector-resonance-multimode instability can be of fundamental interest for the nonlinear dynamics of various distributed systems.

  10. Physics of electrostatic lens

    Science.gov (United States)

    1981-09-01

    The purpose of this program was to study the physics of the ion-energy boosting electrostatic lens for collective ion acceleration in the Luce diode. Extensive work was done in preparation for experiments on the PI Pulserad 1150. Analytic work was done on the orbit of protons in a mass spectrometer and a copper stack for nuclear activation analysis of proton energy spectrum has been designed. Unfortunately, a parallel program which would provide the Luce diode for the collective ion acceleration experiment never materialized. As a result no experiments were actually performed on the Pulserad 1150.

  11. [Intraocular lens implantation in developmental lens disorders in children].

    Science.gov (United States)

    Kanigowska, Krystyna; Grałek, Mirosława; Kepa, Beata; Chipczyńska, Barbara

    2009-01-01

    The pediatric cataract surgery in eyes with developmental disorders, stay with still considerable challenge. At children, the lasting vision development extorts necessity quick settlement of refraction defect formed after operation. The intraocular lens old boy with cataract in microspherophakia and 12 years old boy with cataract in lens with coloboma. One-piece flexible and rigid PMMA intraocular lens was placed with success at posterior chamber without scleral fixations and without using capsular tension ring in this cases. After 3 years of observation there were no decentration or dislocation of intraocular lens in both children. Authors concluded that in some cases posterior chamber intraocular lens implantation despite defective zonular or capsular support, can make up the effective method of surgical treatment without risk of early dislocation.

  12. GRIN介质中的程函方程与光线方程%Eikonal Equation and Equation of Ray in GRIN Media

    Institute of Scientific and Technical Information of China (English)

    郭守月; 穆姝慧; 袁兴红; 周倩

    2011-01-01

    由变折射率(GRIN)介质中光程的定义,不需借助近似理论直接推出程函方程(eikonal equation),再由程函方程推得光线方程的矢量形式,并将矢量形式化简为光线方程的标量形式.应用实例表明该公式更适于已知折射率变化规律的条件下确定光线的轨迹方程.%With the aid of the definition of optical length in gradient index (GRIN) medium, the eikonal equation was deduced without the help of approximate theory, then the vector form of ray equation can be derived by eikonal equation, and finally the vector form of ray equation was simplified into its scalar form. The results of application example show that the equation is especially applicable to determine the equation of ray track in terms of known variation law of refractive index.

  13. The Multimodal Possibilities of Online Instructions

    DEFF Research Database (Denmark)

    Kampf, Constance

    2006-01-01

    The WWW simplifies the process of delivering online instructions through multimodal channels because of the ease of use for voice, video, pictures, and text modes of communication built into it.  Given that instructions are being produced in multimodal format for the WWW, how do multi-modal analy...

  14. Multimodal Friction Ignition Tester

    Science.gov (United States)

    Davis, Eddie; Howard, Bill; Herald, Stephen

    2009-01-01

    The multimodal friction ignition tester (MFIT) is a testbed for experiments on the thermal and mechanical effects of friction on material specimens in pressurized, oxygen-rich atmospheres. In simplest terms, a test involves recording sensory data while rubbing two specimens against each other at a controlled normal force, with either a random stroke or a sinusoidal stroke having controlled amplitude and frequency. The term multimodal in the full name of the apparatus refers to a capability for imposing any combination of widely ranging values of the atmospheric pressure, atmospheric oxygen content, stroke length, stroke frequency, and normal force. The MFIT was designed especially for studying the tendency toward heating and combustion of nonmetallic composite materials and the fretting of metals subjected to dynamic (vibrational) friction forces in the presence of liquid oxygen or pressurized gaseous oxygen test conditions approximating conditions expected to be encountered in proposed composite material oxygen tanks aboard aircraft and spacecraft in flight. The MFIT includes a stainless-steel pressure vessel capable of retaining the required test atmosphere. Mounted atop the vessel is a pneumatic cylinder containing a piston for exerting the specified normal force between the two specimens. Through a shaft seal, the piston shaft extends downward into the vessel. One of the specimens is mounted on a block, denoted the pressure block, at the lower end of the piston shaft. This specimen is pressed down against the other specimen, which is mounted in a recess in another block, denoted the slip block, that can be moved horizontally but not vertically. The slip block is driven in reciprocating horizontal motion by an electrodynamic vibration exciter outside the pressure vessel. The armature of the electrodynamic exciter is connected to the slip block via a horizontal shaft that extends into the pressure vessel via a second shaft seal. The reciprocating horizontal

  15. Multimodal pain management and arthrofibrosis.

    Science.gov (United States)

    Lavernia, Carlos; Cardona, Diego; Rossi, Mark D; Lee, David

    2008-09-01

    Pain control after arthroplasty has been a key concern for orthopedic surgeons. After total knee arthroplasty (TKA), a small group of patients developed a painful joint with suboptimal range of motion. Manipulation under anesthesia increases flexion and extension while decreasing pain in most cases. The objective of the present investigation is to asses the effect of a multimodal pain management protocol on arthrofibrosis in primary TKAs. A cohort of 1136 patients who underwent primary TKA was selected. Patients were divided into 2 groups: group A had 778 procedures performed using a traditional approach to pain control; group B included 358 procedures that received multimodal pain management. Group A had an incidence of manipulation of 4.75% (37/778). Of 357 patients, 8 required manipulation in group B, which is an incidence of 2.24%. We recommend that orthopedic surgeons consider using a multimodal pain management protocol for TKA.

  16. Panoramic lens applications revisited

    Science.gov (United States)

    Thibault, Simon

    2008-04-01

    During the last few years, innovative optical design strategies to generate and control image mapping have been successful in producing high-resolution digital imagers and projectors. This new generation of panoramic lenses includes catadioptric panoramic lenses, panoramic annular lenses, visible/IR fisheye lenses, anamorphic wide-angle attachments, and visible/IR panomorph lenses. Given that a wide-angle lens images a large field of view on a limited number of pixels, a systematic pixel-to-angle mapping will help the efficient use of each pixel in the field of view. In this paper, we present several modern applications of these modern types of hemispheric lenses. Recently, surveillance and security applications have been proposed and published in Security and Defence symposium. However, modern hemispheric lens can be used in many other fields. A panoramic imaging sensor contributes most to the perception of the world. Panoramic lenses are now ready to be deployed in many optical solutions. Covered applications include, but are not limited to medical imaging (endoscope, rigiscope, fiberscope...), remote sensing (pipe inspection, crime scene investigation, archeology...), multimedia (hemispheric projector, panoramic image...). Modern panoramic technologies allow simple and efficient digital image processing and the use of standard image analysis features (motion estimation, segmentation, object tracking, pattern recognition) in the complete 360° hemispheric area.

  17. Switchable lasing in multimode microcavities

    DEFF Research Database (Denmark)

    Zhukovsky, Sergei V.; Chigrin, Dmitry N.; Lavrinenko, Andrei

    2007-01-01

    We propose the new concept of a switchable multimode microlaser. As a generic, realistic model of a multimode microresonator a system of two coupled defects in a two-dimensional photonic crystal is considered. We demonstrate theoretically that lasing of the cavity into one selected resonator mode...... can be caused by injecting an appropriate optical pulse at the onset of laser action (injection seeding). Temporal mode-to-mode switching by reseeding the cavity after a short cooldown period is demonstrated by direct numerical solution. A qualitative analytical explanation of the mode switching...

  18. Multimodal Aspects of Corporate Social Responsibility Communication

    Directory of Open Access Journals (Sweden)

    Carmen Daniela Maier

    2014-12-01

    Full Text Available This article addresses how the multimodal persuasive strategies of corporate social responsibility communication can highlight a company’s commitment to gender empowerment and environmental protection while advertising simultaneously its products. Drawing on an interdisciplinary methodological framework related to CSR communication, multimodal discourse analysis and gender theory, the article proposes a multimodal analysis model through which it is possible to map and explain the multimodal persuasive strategies employed by Coca-Cola company in their community-related films. By examining the semiotic modes’ interconnectivity and functional differentiation, this analytical endeavour expands the existing research work as the usual textual focus is extended to a multimodal one.

  19. A Learning Algorithm for Multimodal Grammar Inference.

    Science.gov (United States)

    D'Ulizia, A; Ferri, F; Grifoni, P

    2011-12-01

    The high costs of development and maintenance of multimodal grammars in integrating and understanding input in multimodal interfaces lead to the investigation of novel algorithmic solutions in automating grammar generation and in updating processes. Many algorithms for context-free grammar inference have been developed in the natural language processing literature. An extension of these algorithms toward the inference of multimodal grammars is necessary for multimodal input processing. In this paper, we propose a novel grammar inference mechanism that allows us to learn a multimodal grammar from its positive samples of multimodal sentences. The algorithm first generates the multimodal grammar that is able to parse the positive samples of sentences and, afterward, makes use of two learning operators and the minimum description length metrics in improving the grammar description and in avoiding the over-generalization problem. The experimental results highlight the acceptable performances of the algorithm proposed in this paper since it has a very high probability of parsing valid sentences.

  20. The Deep Lens Survey

    CERN Document Server

    Wittman, D; Dell'Antonio, I P; Becker, A C; Margoniner, V E; Cohen, J; Norman, D; Loomba, D; Squires, G; Wilson, G; Stubbs, C; Hennawi, J F; Spergel, D N; Boeshaar, P C; Clocchiatti, A; Hamuy, M; Bernstein, G; González, A; Guhathakurta, R; Hu, W; Seljak, U; Zaritsky, D

    2002-01-01

    The Deep Lens Survey (DLS) is a deep BVRz' imaging survey of seven 2x2 degree fields, with all data to be made public. The primary scientific driver is weak gravitational lensing, but the survey is also designed to enable a wide array of other astrophysical investigations. A unique feature of this survey is the search for transient phenomena. We subtract multiple exposures of a field, detect differences, classify, and release transients on the Web within about an hour of observation. Here we summarize the scientific goals of the DLS, field and filter selection, observing techniques and current status, data reduction, data products and release, and transient detections. Finally, we discuss some lessons which might apply to future large surveys such as LSST.

  1. Integrated processing in multimodal argumentation

    NARCIS (Netherlands)

    Hoven, P.J. van den; Jiang, W.

    2011-01-01

    The question addressed in this paper is simple. If the argumentative function of a multimodal narrative text requires the integration of the information from different modes, among which verbal ones, what model for the order of processing and the integration of information do we need to adopt? Using

  2. Multimodal approach to postoperative recovery

    DEFF Research Database (Denmark)

    Kehlet, Henrik

    2009-01-01

    PURPOSE OF REVIEW: To provide updated information on recent developments within individual components of multimodal interventions to improve postoperative outcome (fast-track methodology). RECENT FINDINGS: The value of the fast-track methodology to improve recovery and decrease hospital stay...

  3. Multimodality as a Sociolinguistic Resource

    Science.gov (United States)

    Collister, Lauren Brittany

    2013-01-01

    This work explores the use of multimodal communication in a community of expert "World of Warcraft"® players and its impact on politeness, identity, and relationships. Players in the community regularly communicated using three linguistic modes quasi-simultaneously: text chat, voice chat, and face-to-face interaction. Using the…

  4. Multimodal imaging of ischemic wounds

    Science.gov (United States)

    Zhang, Shiwu; Gnyawali, Surya; Huang, Jiwei; Liu, Peng; Gordillo, Gayle; Sen, Chandan K.; Xu, Ronald

    2012-12-01

    The wound healing process involves the reparative phases of inflammation, proliferation, and remodeling. Interrupting any of these phases may result in chronically unhealed wounds, amputation, or even patient death. Quantitative assessment of wound tissue ischemia, perfusion, and inflammation provides critical information for appropriate detection, staging, and treatment of chronic wounds. However, no method is available for noninvasive, simultaneous, and quantitative imaging of these tissue parameters. We integrated hyperspectral, laser speckle, and thermographic imaging modalities into a single setup for multimodal assessment of tissue oxygenation, perfusion, and inflammation characteristics. Advanced algorithms were developed for accurate reconstruction of wound oxygenation and appropriate co-registration between different imaging modalities. The multimodal wound imaging system was validated by an ongoing clinical trials approved by OSU IRB. In the clinical trial, a wound of 3mm in diameter was introduced on a healthy subject's lower extremity and the healing process was serially monitored by the multimodal imaging setup. Our experiments demonstrated the clinical usability of multimodal wound imaging.

  5. Multi-Modality Phantom Development

    Energy Technology Data Exchange (ETDEWEB)

    Huber, Jennifer S.; Peng, Qiyu; Moses, William W.

    2009-03-20

    Multi-modality imaging has an increasing role in the diagnosis and treatment of a large number of diseases, particularly if both functional and anatomical information are acquired and accurately co-registered. Hence, there is a resulting need for multi modality phantoms in order to validate image co-registration and calibrate the imaging systems. We present our PET-ultrasound phantom development, including PET and ultrasound images of a simple prostate phantom. We use agar and gelatin mixed with a radioactive solution. We also present our development of custom multi-modality phantoms that are compatible with PET, transrectal ultrasound (TRUS), MRI and CT imaging. We describe both our selection of tissue mimicking materials and phantom construction procedures. These custom PET-TRUS-CT-MRI prostate phantoms use agargelatin radioactive mixtures with additional contrast agents and preservatives. We show multi-modality images of these custom prostate phantoms, as well as discuss phantom construction alternatives. Although we are currently focused on prostate imaging, this phantom development is applicable to many multi-modality imaging applications.

  6. Multimode laser beam analyzer instrument using electrically programmable optics.

    Science.gov (United States)

    Marraccini, Philip J; Riza, Nabeel A

    2011-12-01

    Presented is a novel design of a multimode laser beam analyzer using a digital micromirror device (DMD) and an electronically controlled variable focus lens (ECVFL) that serve as the digital and analog agile optics, respectively. The proposed analyzer is a broadband laser characterization instrument that uses the agile optics to smartly direct light to the required point photodetectors to enable beam measurements of minimum beam waist size, minimum waist location, divergence, and the beam propagation parameter M(2). Experimental results successfully demonstrate these measurements for a 500 mW multimode test laser beam with a wavelength of 532 nm. The minimum beam waist, divergence, and M(2) experimental results for the test laser are found to be 257.61 μm, 2.103 mrad, 1.600 and 326.67 μm, 2.682 mrad, 2.587 for the vertical and horizontal directions, respectively. These measurements are compared to a traditional scan method and the results of the beam waist are found to be within error tolerance of the demonstrated instrument.

  7. Association Study of N-Methyl-D-Aspartate Receptor Subunit 2B (GRIN2B Polymorphisms and Schizophrenia Symptoms in the Han Chinese Population.

    Directory of Open Access Journals (Sweden)

    Yongfeng Yang

    Full Text Available Schizophrenia (SZ is a common and complex psychiatric disorder that has a significant genetic component. The glutamatergic system is the major excitatory neurotransmitter system in the central nervous system, and is mediated by N-methyl-D-aspartate (NMDA receptors. Disturbances in this system have been hypothesized to play a major role in SZ pathogenesis. Several studies have revealed that the NMDA receptor subunit 2B (GRIN2B potentially associates with SZ and its psychiatric symptoms. In this study, we performed a case-control study to identify polymorphisms of the GRIN2B gene that may confer susceptibility to SZ in the Han Chinese population. Thirty-four single nucleotide polymorphisms (SNPs were genotyped in 528 paranoid SZ patients and 528 control subjects. A significant association was observed in allele and genotype between SZ and controls at rs2098469 (χ2 = 8.425 and 4.994; p = 0.025 and 0.014, respectively. Significant associations were found in the allele at rs12319804 (χ2 = 4.436; p = 0.035, as well as in the genotype at rs12820037 and rs7298664 between SZ and controls (χ2 = 11.162 and 38.204; p = 0.003 and 4.27×10(-8, respectively. After applying the Bonferroni correction, rs7298664 still had significant genotype associations with SZ (p = 1.71×10(-7. In addition, rs2098469 genotype and allele frequencies, and 12820037 allele frequencies were nominally associated with SZ. Three haplotypes, CGA (rs10845849-rs12319804-rs10845851, CC (rs12582848-rs7952915, and AAGAC (rs2041986-rs11055665-rs7314376-rs7297101-rs2098469, had significant differences between SZ and controls (χ2 = 4.324, 4.582, and 4.492; p = 0.037, 0.032, and 0.034, respectively. In addition, three SNPs, rs2098469, rs12820037, and rs7298664, were significantly associated with cognition factors PANSS subscores in SZ (F = 16.799, 7.112, and 13.357; p = 0.000, 0.017, and 0.000, respectively. In conclusion, our study provides novel evidence for an association between GRIN2B

  8. Association Study of N-Methyl-D-Aspartate Receptor Subunit 2B (GRIN2B) Polymorphisms and Schizophrenia Symptoms in the Han Chinese Population

    Science.gov (United States)

    Zhang, Hongxing; Yang, Ge; Wang, Xiujuan; Ding, Minli; Jiang, Tianzi; Lv, Luxian

    2015-01-01

    Schizophrenia (SZ) is a common and complex psychiatric disorder that has a significant genetic component. The glutamatergic system is the major excitatory neurotransmitter system in the central nervous system, and is mediated by N-methyl-D-aspartate (NMDA) receptors. Disturbances in this system have been hypothesized to play a major role in SZ pathogenesis. Several studies have revealed that the NMDA receptor subunit 2B (GRIN2B) potentially associates with SZ and its psychiatric symptoms. In this study, we performed a case–control study to identify polymorphisms of the GRIN2B gene that may confer susceptibility to SZ in the Han Chinese population. Thirty-four single nucleotide polymorphisms (SNPs) were genotyped in 528 paranoid SZ patients and 528 control subjects. A significant association was observed in allele and genotype between SZ and controls at rs2098469 (χ2 = 8.425 and 4.994; p = 0.025 and 0.014, respectively). Significant associations were found in the allele at rs12319804 (χ2 = 4.436; p = 0.035), as well as in the genotype at rs12820037 and rs7298664 between SZ and controls (χ2 = 11.162 and 38.204; p = 0.003 and 4.27×10-8, respectively). After applying the Bonferroni correction, rs7298664 still had significant genotype associations with SZ (p = 1.71×10-7). In addition, rs2098469 genotype and allele frequencies, and 12820037 allele frequencies were nominally associated with SZ. Three haplotypes, CGA (rs10845849—rs12319804—rs10845851), CC (rs12582848—rs7952915), and AAGAC (rs2041986—rs11055665—rs7314376—rs7297101—rs2098469), had significant differences between SZ and controls (χ2 = 4.324, 4.582, and 4.492; p = 0.037, 0.032, and 0.034, respectively). In addition, three SNPs, rs2098469, rs12820037, and rs7298664, were significantly associated with cognition factors PANSS subscores in SZ (F = 16.799, 7.112, and 13.357; p = 0.000, 0.017, and 0.000, respectively). In conclusion, our study provides novel evidence for an association between

  9. Transferring Lens Prescriptions Between Lens-Design Programs

    Science.gov (United States)

    Stacy, John E.; Wooley, Laura; Carlin, Brian

    1989-01-01

    Optical Lens Prescription Data Formatter computer program enables user to transfer complicated lens prescriptions quickly and easily from one major optical-design program to another and back again. One can take advantage of inherent strength of either program. Programs are ACCOS V from Scientific Calculations, Inc., of Fishers, NY, and CODE V from Optical Research Associates of Pasadena, CA. VAX version written in FORTRAN.

  10. Multimode-singlemode-multimode fiber sensor for alcohol sensing application

    Science.gov (United States)

    Rofi'ah, Iftihatur; Hatta, A. M.; Sekartedjo, Sekartedjo

    2016-11-01

    Alcohol is volatile and flammable liquid which is soluble substances both on polar and non polar substances that has been used in some industrial sectors. Alcohol detection method now widely used one of them is the optical fiber sensor. In this paper used fiber optic sensor based on Multimode-Single-mode-Multimode (MSM) to detect alcohol solution at a concentration range of 0-3%. The working principle of sensor utilizes the modal interference between the core modes and the cladding modes, thus make the sensor sensitive to environmental changes. The result showed that characteristic of the sensor not affect the length of the single-mode fiber (SMF). We obtain that the sensor with a length of 5 mm of single-mode can sensing the alcohol with a sensitivity of 0.107 dB/v%.

  11. Connexin hemichannels in the lens

    Directory of Open Access Journals (Sweden)

    Eric C Beyer

    2014-02-01

    Full Text Available The normal function and survival of cells in the avascular lens is facilitated by intercellular communication through an extensive network of gap junctions formed predominantly by three connexins (Cx43, Cx46, and Cx50. In expression systems, these connexins can all induce hemi-channel currents, but other lens proteins (e.g., pannexin1 can also induce similar currents. Hemichannel currents have been detected in isolated lens fiber cells. These hemichannels may make significant contributions to normal lens physiology and pathophysiology. Studies of some connexin mutants linked to congenital cataracts have implicated hemichannels with aberrant voltage-dependent gating or modulation by divalent cations in disease pathogenesis. Hemichannels may also contribute to age- and disease-related cataracts.

  12. The application of tapered multi-mode fiber in laser signal simulation

    Science.gov (United States)

    Yin, Ruiguang; Guo, Hao; Liang, Weiwei; Zhang, Wenpan; Li, Hui

    2016-09-01

    According to laser signal simulation, the advantage of application of tapered multi-mode fiber on laser pulse signal transmission was analyzed. By optical system simulation, the effect on the coupling efficiency of 1.06μm laser pulse signal of different angle was analyzed. By optical experiment, the coupling efficiency and transmission mode of different incident angle and force condition were confirmed. Combining the application of simulation system, with convex lens, frosted glass and optical integrator on the outlet of fiber, the far-field energy distribution was measured. According the receiving optical system entrance pupil, the effect on the beam quality to the simulation result was analyzed. The results showed that the application of tapered multi-mode fiber on laser pulse signal simulation is feasible, and the equipment has been used in the engineering projects.

  13. Gravitational lens surveys with LOFAR

    CERN Document Server

    Wucknitz, O

    2008-01-01

    Deep surveys planned as a Key Science Project of LOFAR provide completely new opportunities for gravitational lens searches. For the first time do large-scale surveys reach the resolution required for a direct selection of lens candidates using morphological criteria. We briefly describe the strategies that we will use to exploit this potential. The long baselines of an international E-LOFAR are essential for this project.

  14. Ascorbate in the ocular lens

    OpenAIRE

    Mody, Vino C. Jr

    2006-01-01

    Purpose: First, we intended to establish a method for sample preparation for measurement of ascorbate in whole rat and guinea pig lenses utilizing ultrafiltration and high performance liquid chromatography with ultraviolet radiation detection. Then, we aimed to investigate whether, in the albino rat, lens ascorbate concentration depends on solid dietary intake. Finally, we investigated if, in the pigmented guinea pig, lens ascorbate concentration may be elevated with drinkin...

  15. Phakic Intraocular lens- a review

    OpenAIRE

    Cruz, Francisco Miguel

    2015-01-01

    Introduction: Intraocular refractive procedures with the implantation of a Phakic Intraocular lens have become a safe efficient and predictable alternative for treating high ametropias when the use of corneal photoablative procedures is not possible. The implantation of Phakic intraocular lens preservs the accomodative function,is a reversable refractive procedure, with minimal induction of higher order aberrations compaed with corneal photoablative procedures. Methods: An analytical review o...

  16. A course in lens design

    CERN Document Server

    Velzel, Chris

    2014-01-01

    A Course in Lens Design is an instruction in the design of image-forming optical systems. It teaches how a satisfactory design can be obtained in a straightforward way. Theory is limited to a minimum, and used to support the practical design work. The book introduces geometrical optics, optical instruments and aberrations. It gives a description of the process of lens design and of the strategies used in this process. Half of its content is devoted to the design of sixteen types of lenses, described in detail from beginning to end. This book is different from most other books on lens design because it stresses the importance of the initial phases of the design process: (paraxial) lay-out and (thin-lens) pre-design. The argument for this change of accent is that in these phases much information can be obtained about the properties of the lens to be designed. This information can be used in later phases of the design. This makes A Course in Lens Design a useful self-study book, and a suitable basis for an intro...

  17. Inorganic Nanoparticles for Multimodal Molecular Imaging

    Directory of Open Access Journals (Sweden)

    Magdalena Swierczewska

    2011-01-01

    Full Text Available Multimodal molecular imaging can offer a synergistic improvement of diagnostic ability over a single imaging modality. Recent development of hybrid imaging systems has profoundly impacted the pool of available multimodal imaging probes. In particular, much interest has been focused on biocompatible, inorganic nanoparticle-based multimodal probes. Inorganic nanoparticles offer exceptional advantages to the field of multimodal imaging owing to their unique characteristics, such as nanometer dimensions, tunable imaging properties, and multifunctionality. Nanoparticles mainly based on iron oxide, quantum dots, gold, and silica have been applied to various imaging modalities to characterize and image specific biologic processes on a molecular level. A combination of nanoparticles and other materials such as biomolecules, polymers, and radiometals continue to increase functionality for in vivo multimodal imaging and therapeutic agents. In this review, we discuss the unique concepts, characteristics, and applications of the various multimodal imaging probes based on inorganic nanoparticles.

  18. Cognitive Principles in Robust Multimodal Interpretation

    CERN Document Server

    Chai, J Y; Qu, S; 10.1613/jair.1936

    2011-01-01

    Multimodal conversational interfaces provide a natural means for users to communicate with computer systems through multiple modalities such as speech and gesture. To build effective multimodal interfaces, automated interpretation of user multimodal inputs is important. Inspired by the previous investigation on cognitive status in multimodal human machine interaction, we have developed a greedy algorithm for interpreting user referring expressions (i.e., multimodal reference resolution). This algorithm incorporates the cognitive principles of Conversational Implicature and Givenness Hierarchy and applies constraints from various sources (e.g., temporal, semantic, and contextual) to resolve references. Our empirical results have shown the advantage of this algorithm in efficiently resolving a variety of user references. Because of its simplicity and generality, this approach has the potential to improve the robustness of multimodal input interpretation.

  19. Multimodal Biometrics using Feature Fusion

    Directory of Open Access Journals (Sweden)

    K. Krishneswari

    2012-01-01

    Full Text Available Problem statement: Biometrics is a unique, measurable physiological or behavioural characteristic of a person and finds extensive applications in authentication and authorization. Fingerprint, palm print, iris, voice, are some of the most widely used biometrics for personal identification. To reduce the error rates and enhance the usability of biometric system, multimodal biometric systems are used where more than one biometric characteristics are used. Approach: In this study it is proposed to investigate the performance of multimodal biometrics using palm print and fingerprint. Features are extracted using Discrete Cosine Transform (DCT and attributes selected using Information Gain (IG. Results and Conclusion: The proposed technique shows an average improvement of 8.52% compared to using palmprint technique alone. The processing time does not increase for verification compared to palm print techniques.

  20. Continuous verification using multimodal biometrics.

    Science.gov (United States)

    Sim, Terence; Zhang, Sheng; Janakiraman, Rajkumar; Kumar, Sandeep

    2007-04-01

    Conventional verification systems, such as those controlling access to a secure room, do not usually require the user to reauthenticate himself for continued access to the protected resource. This may not be sufficient for high-security environments in which the protected resource needs to be continuously monitored for unauthorized use. In such cases, continuous verification is needed. In this paper, we present the theory, architecture, implementation, and performance of a multimodal biometrics verification system that continuously verifies the presence of a logged-in user. Two modalities are currently used--face and fingerprint--but our theory can be readily extended to include more modalities. We show that continuous verification imposes additional requirements on multimodal fusion when compared to conventional verification systems. We also argue that the usual performance metrics of false accept and false reject rates are insufficient yardsticks for continuous verification and propose new metrics against which we benchmark our system.

  1. The bicriterion multimodal assignment problem

    DEFF Research Database (Denmark)

    Pedersen, Christian Roed; Nielsen, Lars Relund; Andersen, Kim Allan

    2008-01-01

    We consider the bicriterion multimodal assignment problem, which is a new generalization of the classical linear assignment problem. A two-phase solution method using an effective ranking scheme is presented. The algorithm is valid for generating all nondominated criterion points...... or an approximation. Extensive computational results are conducted on a large library of test instances to test the performance of the algorithm and to identify hard test instances. Also, test results of the algorithm applied to the bicriterion assignment problem are provided....

  2. Evaluation of multimodal ground cues

    DEFF Research Database (Denmark)

    Nordahl, Rolf; Lecuyer, Anatole; Serafin, Stefania

    2012-01-01

    This chapter presents an array of results on the perception of ground surfaces via multiple sensory modalities,with special attention to non visual perceptual cues, notably those arising from audition and haptics, as well as interactions between them. It also reviews approaches to combining synth...... synthetic multimodal cues, from vision, haptics, and audition, in order to realize virtual experiences of walking on simulated ground surfaces or other features....

  3. The Theme in the Multimodality

    Institute of Scientific and Technical Information of China (English)

    Liu; Xiaolin

    2014-01-01

    <正>1.Systemic Functional Linguistic(SFL)and Multimodality The theoretical foundation for this analysis is mainly extrapolated from the approach of language as a social semiotic process(Halliday 1978,2004).SFL deals with the way texts are articulated to be appropriate for particular situations of use.Halliday develops a Systemic Functional approach in relation to verbal language and offers a set of grammatical systems which realize the three metafunctions of language.In them,the clause

  4. Multi-Mode Broadband Patch Antenna

    Science.gov (United States)

    Romanofsky, Robert R. (Inventor)

    2001-01-01

    A multi-mode broad band patch antenna is provided that allows for the same aperture to be used at independent frequencies such as reception at 19 GHz and transmission at 29 GHz. Furthermore, the multi-mode broadband patch antenna provides a ferroelectric film that allows for tuning capability of the multi-mode broadband patch antenna over a relatively large tuning range. The alternative use of a semiconductor substrate permits reduced control voltages since the semiconductor functions as a counter electrode.

  5. Multimodal CT in stroke imaging: new concepts.

    Science.gov (United States)

    Ledezma, Carlos J; Wintermark, Max

    2009-01-01

    A multimodal CT protocol provides a comprehensive noninvasive survey of acute stroke patients with accurate demonstration of the site of arterial occlusion and its hemodynamic tissue status. It combines widespread availability with the ability to provide functional characterization of cerebral ischemia, and could potentially allow more accurate selection of candidates for acute stroke reperfusion therapy. This article discusses the individual components of multimodal CT and addresses the potential role of a combined multimodal CT stroke protocol in acute stroke therapy.

  6. Multimodal Diversity of Postmodernist Fiction Text

    Directory of Open Access Journals (Sweden)

    U. I. Tykha

    2016-12-01

    Full Text Available The article is devoted to the analysis of structural and functional manifestations of multimodal diversity in postmodernist fiction texts. Multimodality is defined as the coexistence of more than one semiotic mode within a certain context. Multimodal texts feature a diversity of semiotic modes in the communication and development of their narrative. Such experimental texts subvert conventional patterns by introducing various semiotic resources – verbal or non-verbal.

  7. Multimodal nanoparticulate bioimaging contrast agents.

    Science.gov (United States)

    Sharma, Parvesh; Singh, Amit; Brown, Scott C; Bengtsson, Niclas; Walter, Glenn A; Grobmyer, Stephen R; Iwakuma, Nobutaka; Santra, Swadeshmukul; Scott, Edward W; Moudgil, Brij M

    2010-01-01

    A wide variety of bioimaging techniques (e.g., ultrasound, computed X-ray tomography, magnetic resonance imaging (MRI), and positron emission tomography) are commonly employed for clinical diagnostics and scientific research. While all of these methods use a characteristic "energy-matter" interaction to provide specific details about biological processes, each modality differs from another in terms of spatial and temporal resolution, anatomical and molecular details, imaging depth, as well as the desirable material properties of contrast agents needed for augmented imaging. On many occasions, it is advantageous to apply multiple complimentary imaging modalities for faster and more accurate prognosis. Since most imaging modalities employ exogenous contrast agents to improve the signal-to-noise ratio, the development and use of multimodal contrast agents is considered to be highly advantageous for obtaining improved imagery from sought-after imaging modalities. Multimodal contrast agents offer improvements in patient care, and at the same time can reduce costs and enhance safety by limiting the number of contrast agent administrations required for imaging purposes. Herein, we describe the synthesis and characterization of nanoparticulate-based multimodal contrast agent for noninvasive bioimaging using MRI, optical, and photoacoustic tomography (PAT)-imaging modalities. The synthesis of these agents is described using microemulsions, which enable facile integration of the desired diversity of contrast agents and material components into a single entity.

  8. Advances in multimodality molecular imaging

    Directory of Open Access Journals (Sweden)

    Zaidi Habib

    2009-01-01

    Full Text Available Multimodality molecular imaging using high resolution positron emission tomography (PET combined with other modalities is now playing a pivotal role in basic and clinical research. The introduction of combined PET/CT systems in clinical setting has revolutionized the practice of diagnostic imaging. The complementarity between the intrinsically aligned anatomic (CT and functional or metabolic (PET information provided in a "one-stop shop" and the possibility to use CT images for attenuation correction of the PET data has been the driving force behind the success of this technology. On the other hand, combining PET with Magnetic Resonance Imaging (MRI in a single gantry is technically more challenging owing to the strong magnetic fields. Nevertheless, significant progress has been made resulting in the design of few preclinical PET systems and one human prototype dedicated for simultaneous PET/MR brain imaging. This paper discusses recent advances in PET instrumentation and the advantages and challenges of multimodality imaging systems. Future opportunities and the challenges facing the adoption of multimodality imaging instrumentation will also be addressed.

  9. Diffusion Maps for Multimodal Registration

    Directory of Open Access Journals (Sweden)

    Gemma Piella

    2014-06-01

    Full Text Available Multimodal image registration is a difficult task, due to the significant intensity variations between the images. A common approach is to use sophisticated similarity measures, such as mutual information, that are robust to those intensity variations. However, these similarity measures are computationally expensive and, moreover, often fail to capture the geometry and the associated dynamics linked with the images. Another approach is the transformation of the images into a common space where modalities can be directly compared. Within this approach, we propose to register multimodal images by using diffusion maps to describe the geometric and spectral properties of the data. Through diffusion maps, the multimodal data is transformed into a new set of canonical coordinates that reflect its geometry uniformly across modalities, so that meaningful correspondences can be established between them. Images in this new representation can then be registered using a simple Euclidean distance as a similarity measure. Registration accuracy was evaluated on both real and simulated brain images with known ground-truth for both rigid and non-rigid registration. Results showed that the proposed approach achieved higher accuracy than the conventional approach using mutual information.

  10. Multimodality imaging of pulmonary infarction

    Energy Technology Data Exchange (ETDEWEB)

    Bray, T.J.P., E-mail: timothyjpbray@gmail.com [Department of Radiology, Papworth Hospital NHS Foundation Trust, Ermine Street, Papworth Everard, Cambridge CB23 3RE (United Kingdom); Mortensen, K.H., E-mail: mortensen@doctors.org.uk [Department of Radiology, Papworth Hospital NHS Foundation Trust, Ermine Street, Papworth Everard, Cambridge CB23 3RE (United Kingdom); University Department of Radiology, Addenbrookes Hospital, Cambridge University Hospitals NHS Foundation Trust, Hills Road, Box 318, Cambridge CB2 0QQ (United Kingdom); Gopalan, D., E-mail: deepa.gopalan@btopenworld.com [Department of Radiology, Papworth Hospital NHS Foundation Trust, Ermine Street, Papworth Everard, Cambridge CB23 3RE (United Kingdom)

    2014-12-15

    Highlights: • A plethora of pulmonary and systemic disorders, often associated with grave outcomes, may cause pulmonary infarction. • A stereotypical infarct is a peripheral wedge shaped pleurally based opacity but imaging findings can be highly variable. • Multimodality imaging is key to diagnosing the presence, aetiology and complications of pulmonary infarction. • Multimodality imaging of pulmonary infarction together with any ancillary features often guide to early targeted treatment. • CT remains the principal imaging modality with MRI increasingly used alongside nuclear medicine studies and ultrasound. - Abstract: The impact of absent pulmonary arterial and venous flow on the pulmonary parenchyma depends on a host of factors. These include location of the occlusive insult, the speed at which the occlusion develops and the ability of the normal dual arterial supply to compensate through increased bronchial arterial flow. Pulmonary infarction occurs when oxygenation is cut off secondary to sudden occlusion with lack of recruitment of the dual supply arterial system. Thromboembolic disease is the commonest cause of such an insult but a whole range of disease processes intrinsic and extrinsic to the pulmonary arterial and venous lumen may also result in infarcts. Recognition of the presence of infarction can be challenging as imaging manifestations often differ from the classically described wedge shaped defect and a number of weighty causes need consideration. This review highlights aetiologies and imaging appearances of pulmonary infarction, utilising cases to illustrate the essential role of a multimodality imaging approach in order to arrive at the appropriate diagnosis.

  11. The 2010 IODC lens design problem: the green lens

    Science.gov (United States)

    Juergens, Richard C.

    2010-08-01

    The lens design problem for the 2010 IODC is to design a 100 mm focal length lens in which every optical surface has the same radius of curvature, positive or negative, or is plano. The lens is used monochromatically at 532 nm and is made of only Schott N-BK7 glass. The goal of the problem is to maximize the product of the semi-field of view and the entrance pupil diameter while holding the distortion to within +/-5% and the RMS wavefront error to <= 0.07 wave within the field of view. There were 37 entries from eight different countries. Four different commercial lens design programs were used, along with two custom, in-house programs. The number of lens elements in the entries ranged from 3 to 64. The overall length of the lenses varied from 105 mm to 3.6 km. The winning entry had an entrance pupil diameter of 81.3 mm and a semi-field of view of 43.5° for a merit function product of 3537.

  12. Multistep ion exchange processes of gradient refractive index rod lens.

    Science.gov (United States)

    Lv, Hao; Liu, Aimei; Tong, Jufang; Yi, Xunong; Li, Qianguang; Wang, Xinmin; Ding, Yaoming

    2011-01-01

    A mathematical model for research on the refractive index profile (RIP) of multistep ion exchange processes (IEPs) of gradient refractive index rod lenses (GRINs) is established by the different initial condition and boundary condition, based on the Fickian diffusion equation. GRIN rod lenses have been fabricated using the three-step IEPs. Research results indicate that the experimental deviations of refractive index (DRI) are in good agreement with the theoretical data. The DRI of three-step IEPs is superior to the one- and two-step IEPs and smaller than 10(-5).

  13. Tinting of intraocular lens implants

    Energy Technology Data Exchange (ETDEWEB)

    Zigman, S.

    1982-06-01

    Intraocular lens (IOL) implants of polymethyl methacrylate (PMMA) lack an important yellow pigment useful as a filter in the visual process and in the protection of the retina from short-wavelength radiant energy. The ability to produce a yellow pigment in the PMMA used in IOL implants by exposure to near-ultraviolet (UV) light was tested. It was found that the highly cross-linked material in Copeland lens blanks was tinted slightly because of this exposure. The absorptive properties of lens blanks treated with near-UV light in this way approached that of the absorptive properties of human lenses. This finding shows that it is possible to alter IOL implants simply so as to induce a pale-yellow pigment in them to improve the visual process and to protect the retinas of IOL users.

  14. International rigid contact lens prescribing.

    Science.gov (United States)

    Efron, Nathan; Morgan, Philip B; Helland, Magne; Itoi, Motozumi; Jones, Deborah; Nichols, Jason J; van der Worp, Eef; Woods, Craig A

    2010-06-01

    Rigid lenses have been fitted less since the introduction of soft lenses nearly 40 years ago. Data that we have gathered from annual contact lens fitting surveys conducted in Australia, Canada, Japan, the Netherlands, Norway, the UK and the USA between 2000 and 2008 facilitate an accurate characterization of the pattern of the decline of rigid lens fitting during the first decade of this century. There is a trend for rigid lenses to be utilized primarily for refitting those patients who are already successful rigid lens wearers-most typically older females being refit with higher Dk materials. Rigid lenses are generally fitted on a full-time basis (four or more days of wear per week) without a planned replacement schedule. Orthokeratology is especially popular in the Netherlands, but is seldom prescribed in the other countries surveyed.

  15. The SNAP Strong Lens Survey

    Energy Technology Data Exchange (ETDEWEB)

    Marshall, P.

    2005-01-03

    Basic considerations of lens detection and identification indicate that a wide field survey of the types planned for weak lensing and Type Ia SNe with SNAP are close to optimal for the optical detection of strong lenses. Such a ''piggy-back'' survey might be expected even pessimistically to provide a catalogue of a few thousand new strong lenses, with the numbers dominated by systems of faint blue galaxies lensed by foreground ellipticals. After sketching out our strategy for detecting and measuring these galaxy lenses using the SNAP images, we discuss some of the scientific applications of such a large sample of gravitational lenses: in particular we comment on the partition of information between lens structure, the source population properties and cosmology. Understanding this partitioning is key to assessing strong lens cosmography's value as a cosmological probe.

  16. Planar immersion lens with metasurfaces

    CERN Document Server

    Ho, John S; Tanabe, Yuji; Yeh, Alexander J; Fan, Shanhui; Poon, Ada S Y

    2015-01-01

    The solid immersion lens is a powerful optical tool that allows light entering material from air or vacuum to focus to a spot much smaller than the free-space wavelength. Conventionally, however, they rely on semispherical topographies and are non-planar and bulky, which limits their integration in many applications. Recently, there has been considerable interest in using planar structures, referred to as metasurfaces, to construct flat optical components for manipulating light in unusual ways. Here, we propose and demonstrate the concept of a planar immersion lens based on metasurfaces. The resulting planar device, when placed near an interface between air and dielectric material, can focus electromagnetic radiation incident from air to a spot in material smaller than the free-space wavelength. As an experimental demonstration, we fabricate an ultrathin and flexible microwave lens and further show that it achieves wireless energy transfer in material mimicking biological tissue.

  17. Algebraic Lens Distortion Model Estimation

    Directory of Open Access Journals (Sweden)

    Luis Alvarez

    2010-07-01

    Full Text Available A very important property of the usual pinhole model for camera projection is that 3D lines in the scene are projected to 2D lines. Unfortunately, wide-angle lenses (specially low-cost lenses may introduce a strong barrel distortion, which makes the usual pinhole model fail. Lens distortion models try to correct such distortion. We propose an algebraic approach to the estimation of the lens distortion parameters based on the rectification of lines in the image. Using the proposed method, the lens distortion parameters are obtained by minimizing a 4 total-degree polynomial in several variables. We perform numerical experiments using calibration patterns and real scenes to show the performance of the proposed method.

  18. Low-loss fiber optic rotary joint using C-lens collimators

    Institute of Scientific and Technical Information of China (English)

    JIA Da-gong; JING Wen-cai; ZHANG Yi-mo; ZHOU Ge; ZHANG Jin; TANG Feng

    2005-01-01

    A low-loss fiber optic rotary joint (FORJ) has been designed by using two kinds of C-lens collimators. Its insertion loss and insertion loss variation due to rotation with single-mode fiber collimator is less than 1.76 dB and 0.43 dB respectively.The maximum insertion loss and coupling variation due to rotation with multi-mode fiber collimator is 1.71 dB and 0.29 dB, respectively. This kind of FORJ features low insertion loss, small coupling variation due to rotation and low cost.

  19. Multimodal Interactions with Agents in Virtual Worlds

    NARCIS (Netherlands)

    Nijholt, A.; Hulstijn, J.; Kasabov, N.

    2000-01-01

    In this chapter we discuss our research on multimodal interaction in a virtual environment. The environment we have developed can be considered as a ‘laboratory’ for research on multimodal interactions and multimedia presentation, where we have multiple users and various agents that help the users t

  20. Multimode optical fibers: steady state mode exciter.

    Science.gov (United States)

    Ikeda, M; Sugimura, A; Ikegami, T

    1976-09-01

    The steady state mode power distribution of the multimode graded index fiber was measured. A simple and effective steady state mode exciter was fabricated by an etching technique. Its insertion loss was 0.5 dB for an injection laser. Deviation in transmission characteristics of multimode graded index fibers can be avoided by using the steady state mode exciter.

  1. Multimodal Literacies in the Secondary English Classroom

    Science.gov (United States)

    Sewell, William C.; Denton, Shawn

    2011-01-01

    To provide insight into the issue of multimodal literacy instruction, the authors explore presentation techniques and instructional activities employed in their secondary language arts classes. They collaborate on assignments that focus students on "anchored media instruction" and engage them in producing multimodal, technology-infused projects,…

  2. Multimodal Narrative Inquiry: Six Teacher Candidates Respond

    Science.gov (United States)

    Morawski, Cynthia M.; Rottmann, Jennifer

    2016-01-01

    In this paper we present findings of a study on the implementation of a multimodal teacher narrative inquiry component, theoretically grounded by Rosenblatt's theory of transaction analysis, methodologically supported by action research and practically enacted by narrative inquiry and multimodal learning. In particular, the component offered…

  3. Multimodal Pedagogies for Teacher Education in TESOL

    Science.gov (United States)

    Yi, Youngjoo; Angay-Crowder, Tuba

    2016-01-01

    As a growing number of English language learners (ELLs) engage in digital and multimodal literacy practices in their daily lives, teachers are starting to incorporate multimodal approaches into their instruction. However, anecdotal and empirical evidence shows that teachers often feel unprepared for integrating such practices into their curricula…

  4. (Re-)Examination of Multimodal Augmented Reality

    NARCIS (Netherlands)

    Rosa, N.E.; Werkhoven, P.J.; Hürst, W.O.

    The majority of augmented reality (AR) research has been concerned with visual perception, however the move towards multimodality is imminent. At the same time, there is no clear vision of what multimodal AR is. The purpose of this position paper is to consider possible ways of examining AR other

  5. Evaluating Multimodal Literacies in Student Blogs

    Science.gov (United States)

    O'Byrne, Barbara; Murrell, Stacey

    2014-01-01

    This research presents ways in which high school students used the multimodal and interactive affordances of blogs to create, organize, communicate and participate on an educational blog. Their actions demonstrated how plural modes of literacy are infiltrating digital environments and reshaping literacy and learning. Multimodal blogging practices…

  6. A cuckoo search algorithm for multimodal optimization.

    Science.gov (United States)

    Cuevas, Erik; Reyna-Orta, Adolfo

    2014-01-01

    Interest in multimodal optimization is expanding rapidly, since many practical engineering problems demand the localization of multiple optima within a search space. On the other hand, the cuckoo search (CS) algorithm is a simple and effective global optimization algorithm which can not be directly applied to solve multimodal optimization problems. This paper proposes a new multimodal optimization algorithm called the multimodal cuckoo search (MCS). Under MCS, the original CS is enhanced with multimodal capacities by means of (1) the incorporation of a memory mechanism to efficiently register potential local optima according to their fitness value and the distance to other potential solutions, (2) the modification of the original CS individual selection strategy to accelerate the detection process of new local minima, and (3) the inclusion of a depuration procedure to cyclically eliminate duplicated memory elements. The performance of the proposed approach is compared to several state-of-the-art multimodal optimization algorithms considering a benchmark suite of fourteen multimodal problems. Experimental results indicate that the proposed strategy is capable of providing better and even a more consistent performance over existing well-known multimodal algorithms for the majority of test problems yet avoiding any serious computational deterioration.

  7. Addressing multimodality in overt aggression detection

    NARCIS (Netherlands)

    Lefter, I.; Rothkrantz, L.J.M.; Burghouts, G.; Yang, Z.; Wiggers, P.

    2011-01-01

    Automatic detection of aggressive situations has a high societal and scientific relevance. It has been argued that using data from multimodal sensors as for example video and sound as opposed to unimodal is bound to increase the accuracy of detections. We approach the problem of multimodal aggressio

  8. The Multimodal Possibilities of Online Instructions

    DEFF Research Database (Denmark)

    Kampf, Constance

    2006-01-01

    The WWW simplifies the process of delivering online instructions through multimodal channels because of the ease of use for voice, video, pictures, and text modes of communication built into it.  Given that instructions are being produced in multimodal format for the WWW, how do multi......-modal analysis tools help us understand the impact of multimodal channels used in instructions?  This paper looks at Kress and VanLeewan's questions of "how narrative is shaped in a specific mode and how it is reshaped when it appears in different modes?" (2001:128)  In addition, the intersection of linguistics...... and rhetoric is explored as a means of understanding the multimodal possibilities for technical communication genres such as instructions....

  9. Multifuel multimodal network design; Projeto de redes multicombustiveis multimodal

    Energy Technology Data Exchange (ETDEWEB)

    Lage, Carolina; Dias, Gustavo; Bahiense, Laura; Ferreira Filho, Virgilio J.M. [Universidade Federal do Rio de Janeiro (UFRJ), RJ (Brazil). Coordenacao dos Programas de Pos-graduacao de Engenharia (COPPE). Programa de Engenharia de Producao

    2008-07-01

    The objective of the Multi commodity Multimodal Network Project is the development of modeling tools and methodologies for the optimal sizing of production networks and multimodal distribution of multiple fuel and its incomes, considering investments and transportation costs. Given the inherently non-linear combinatory nature of the problem, the resolution of real instances by the complete model, in an exact way, becomes computationally intractable. Thus, the strategy for resolution should contain a combination of exacts and heuristics methods, that must be applied to subdivisions of the original problem. This paper deals with one of these subdivisions, tackling the problem of modeling a network of pipelines in order to drain the production of ethanol away from the producing plants. The objective consists in defining the best network topology, minimizing investment and operational costs, and attending the total demand. In order to do that, the network was considered a tree, where the nodes are the center of producing regions and the edges are the pipelines, trough where the ethanol produced by plants must be drained away. The main objective also includes the decision over the optimal diameter of each pipeline and the optimal size of the bombs, in order to minimize the pumping costs. (author)

  10. Metawidgets in the multimodal interface

    Energy Technology Data Exchange (ETDEWEB)

    Blattner, M.M. (Lawrence Livermore National Lab., CA (United States) Anderson (M.D.) Cancer Center, Houston, TX (United States)); Glinert, E.P.; Jorge, J.A.; Ormsby, G.R. (Rensselaer Polytechnic Inst., Troy, NY (United States). Dept. of Computer Science)

    1991-01-01

    We analyze two intertwined and fundamental issues concerning computer-to-human communication in the multimodal interfaces: the interplay between sound and graphics, and the role of object persistence. Our observations lead us to introduce metawidgets as abstract entities capable of manifesting themselves to users as image, as sound, or as various combinations and/or sequences of the two media. We show examples of metawidgets in action, and discuss mechanisms for choosing among alternative media for metawidget instantiation. Finally, we describe a couple of experimental microworlds we have implemented to test out some of our ideas. 17 refs., 7 figs.

  11. Multimodal Treatment of Chronic Pain.

    Science.gov (United States)

    Dale, Rebecca; Stacey, Brett

    2016-01-01

    Most patients with chronic pain receive multimodal treatment. There is scant literature to guide us, but when approaching combination pharmacotherapy, the practitioner and patient must weigh the benefits with the side effects; many medications have modest effect yet carry significant side effects that can be additive. Chronic pain often leads to depression, anxiety, and deconditioning, which are targets for treatment. Structured interdisciplinary programs are beneficial but costly. Interventions have their place in the treatment of chronic pain and should be a part of a multidisciplinary treatment plan. Further research is needed to validate many common combination treatments.

  12. Modal dynamics in multimode fibers

    CERN Document Server

    Fridman, Moti; Nixon, Micha; Friesem, Asher A; Davidson, Nir

    2010-01-01

    The dynamics of modes and their states of polarizations in multimode fibers as a function of time, space, and wavelength are experimentally and theoretically investigated. The results reveal that the states of polarizations are displaced in Poincare sphere representation when varying the angular orientations of the polarization at the incident light. Such displacements, which complicates the interpretation of the results, are overcome by resorting to modified Poincare spheres representation. With such modification it should be possible to predict the output modes and their state of polarization when the input mode and state of polarization are known.

  13. Multimodal therapy in perioperative analgesia.

    Science.gov (United States)

    Gritsenko, Karina; Khelemsky, Yury; Kaye, Alan David; Vadivelu, Nalini; Urman, Richard D

    2014-03-01

    This article reviews the current evidence for multimodal analgesic options for common surgical procedures. As perioperative physicians, we have come a long way from using only opioids for postoperative pain to combinations of acetaminophen, nonsteroidal anti-inflammatory drugs (NSAIDs), selective Cyclo-oxygenase (COX-2) inhibitors, local anesthetics, N-methyl-d-aspartate (NMDA) receptor antagonists, and regional anesthetics. As discussed in this article, many of these agents have decreased narcotic requirements, improved patient satisfaction, and decreased postanesthesia care unit (PACU) times, as well as morbidity in the perioperative period.

  14. Panoramic lens designed with transformation optics

    Science.gov (United States)

    Wang, Huaping; Deng, Yangyang; Zheng, Bin; Li, Rujiang; Jiang, Yuyu; Dehdashti, Shahram; Xu, Zhiwei; Chen, Hongsheng

    2017-01-01

    The panoramic lens is a special kind of lens, which is applied to observe full view. In this letter, we theoretically present a panoramic lens (PL) using transformation optics method. The lens is designed with inhomogeneous and anisotropic constitutive parameters, which has the ability to gather light from all directions and confine light within the visual angle of observer. Simulation results validate our theoretical design.

  15. SimpLens: Interactive gravitational lensing simulator

    Science.gov (United States)

    Saha, Prasenjit; Williams, Liliya L. R.

    2016-06-01

    SimpLens illustrates some of the theoretical ideas important in gravitational lensing in an interactive way. After setting parameters for elliptical mass distribution and external mass, SimpLens displays the mass profile and source position, the lens potential and image locations, and indicate the image magnifications and contours of virtual light-travel time. A lens profile can be made shallower or steeper with little change in the image positions and with only total magnification affected.

  16. In vivo human crystalline lens topography.

    Science.gov (United States)

    Ortiz, Sergio; Pérez-Merino, Pablo; Gambra, Enrique; de Castro, Alberto; Marcos, Susana

    2012-10-01

    Custom high-resolution high-speed anterior segment spectral domain optical coherence tomography (OCT) was used to characterize three-dimensionally (3-D) the human crystalline lens in vivo. The system was provided with custom algorithms for denoising and segmentation of the images, as well as for fan (scanning) and optical (refraction) distortion correction, to provide fully quantitative images of the anterior and posterior crystalline lens surfaces. The method was tested on an artificial eye with known surfaces geometry and on a human lens in vitro, and demonstrated on three human lenses in vivo. Not correcting for distortion overestimated the anterior lens radius by 25% and the posterior lens radius by more than 65%. In vivo lens surfaces were fitted by biconicoids and Zernike polynomials after distortion correction. The anterior lens radii of curvature ranged from 10.27 to 14.14 mm, and the posterior lens radii of curvature ranged from 6.12 to 7.54 mm. Surface asphericities ranged from -0.04 to -1.96. The lens surfaces were well fitted by quadrics (with variation smaller than 2%, for 5-mm pupils), with low amounts of high order terms. Surface lens astigmatism was significant, with the anterior lens typically showing horizontal astigmatism ([Formula: see text] ranging from -11 to -1 µm) and the posterior lens showing vertical astigmatism ([Formula: see text] ranging from 6 to 10 µm).

  17. 21 CFR 886.3600 - Intraocular lens.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Intraocular lens. 886.3600 Section 886.3600 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES OPHTHALMIC DEVICES Prosthetic Devices § 886.3600 Intraocular lens. (a) Identification. An intraocular lens is a device made of materials...

  18. Cardiac imaging. A multimodality approach

    Energy Technology Data Exchange (ETDEWEB)

    Thelen, Manfred [Johannes Gutenberg University Hospital, Mainz (Germany); Erbel, Raimund [University Hospital Essen (Germany). Dept. of Cardiology; Kreitner, Karl-Friedrich [Johannes Gutenberg University Hospital, Mainz (Germany). Clinic and Polyclinic for Diagnostic and Interventional Radiology; Barkhausen, Joerg (eds.) [University Hospital Schleswig-Holstein, Luebeck (Germany). Dept. of Radiology and Nuclear Medicine

    2009-07-01

    An excellent atlas on modern diagnostic imaging of the heart Written by an interdisciplinary team of experts, Cardiac Imaging: A Multimodality Approach features an in-depth introduction to all current imaging modalities for the diagnostic assessment of the heart as well as a clinical overview of cardiac diseases and main indications for cardiac imaging. With a particular emphasis on CT and MRI, the first part of the atlas also covers conventional radiography, echocardiography, angiography and nuclear medicine imaging. Leading specialists demonstrate the latest advances in the field, and compare the strengths and weaknesses of each modality. The book's second part features clinical chapters on heart defects, endocarditis, coronary heart disease, cardiomyopathies, myocarditis, cardiac tumors, pericardial diseases, pulmonary vascular diseases, and diseases of the thoracic aorta. The authors address anatomy, pathophysiology, and clinical features, and evaluate the various diagnostic options. Key features: - Highly regarded experts in cardiology and radiology off er image-based teaching of the latest techniques - Readers learn how to decide which modality to use for which indication - Visually highlighted tables and essential points allow for easy navigation through the text - More than 600 outstanding images show up-to-date technology and current imaging protocols Cardiac Imaging: A Multimodality Approach is a must-have desk reference for cardiologists and radiologists in practice, as well as a study guide for residents in both fields. It will also appeal to cardiac surgeons, general practitioners, and medical physicists with a special interest in imaging of the heart. (orig.)

  19. Untangled modes in multimode waveguides

    Science.gov (United States)

    Plöschner, Martin; Tyc, TomáÅ.¡; Čižmár, TomáÅ.¡

    2016-03-01

    Small, fibre-based endoscopes have already improved our ability to image deep within the human body. A novel approach introduced recently utilised disordered light within a standard multimode optical fibre for lensless imaging. Importantly, this approach brought very significant reduction of the instruments footprint to dimensions below 100 μm. The most important limitations of this exciting technology is the lack of bending flexibility - imaging is only possible as long as the fibre remains stationary. The only route to allow flexibility of such endoscopes is in trading-in all the knowledge about the optical system we have, particularly the cylindrical symmetry of refractive index distribution. In perfect straight step-index cylindrical waveguides we can find optical modes that do not change their spatial distribution as they propagate through. In this paper we present a theoretical background that provides description of such modes in more realistic model of real-life step-index multimode fibre taking into account common deviations in distribution of the refractive index from its ideal step-index profile. Separately, we discuss how to include the influence of fibre bending.

  20. Professoren og Ålen

    DEFF Research Database (Denmark)

    Poulsen, Bo

    2016-01-01

    Biolog og havforsker Johannes Schmidt regnes for at være Danmarks mest betydningsfulde havforsker gennem tiderne. Hans mange forskningsbaserede jordomsejlinger bragte ham til eksotiske egne og til opdagelsen af adskillige nye dyrearter. Dog blev særligt ålen og dens gydepladser et hovedfokus...

  1. Professoren og Ålen

    DEFF Research Database (Denmark)

    Poulsen, Bo

    2016-01-01

    Biolog og havforsker Johannes Schmidt regnes for at være Danmarks mest betydningsfulde havforsker gennem tiderne. Hans mange forskningsbaserede jordomsejlinger bragte ham til eksotiske egne og til opdagelsen af adskillige nye dyrearter. Dog blev særligt ålen og dens gydepladser et hovedfokus for ...

  2. The Ultrawideband Leaky Lens Antenna

    NARCIS (Netherlands)

    Bruni, S.; Neto, A.; Marliani, F.

    2007-01-01

    A novel directive and nondispersive antenna is presented: the ultrawideband (UWB) leaky lens. It is based on the broad band Cherenkov radiation occurring at a slot printed between different infinite homogeneous dielectrics. The first part of the paper presents the antenna concept and the UWB design.

  3. Estimation of the hybrid lens parameters through rigid gas permeable lens fitting

    OpenAIRE

    Hasani, Mohammadali; Hashemi, Hassan; Jafarzadehpur, Ebrahim; Yekta, Abbas Ali; Dadbin, Nooshin; khabazkhoob, Mehdi

    2016-01-01

    Purpose To estimate the fitting parameters of the hybrid contact lens in patients with corneal ectasia using the rigid gas permeable (RGP) lens. Methods Thirty-four eyes with corneal ectasia were evaluated in this study. The patients were examined once with the RGP lens and once with the hybrid contact lens. The relationship between the base curvature of the RGP and the vault of the hybrid lens and the correlation between their powers were analyzed. Results We found a linear relationship betw...

  4. Multifocal contact lens myopia control.

    Science.gov (United States)

    Walline, Jeffrey J; Greiner, Katie L; McVey, M Elizabeth; Jones-Jordan, Lisa A

    2013-11-01

    Previous studies on soft multifocal contact lens myopia control published in the peer-reviewed literature reported findings of noncommercial contact lenses worn for 1 year or less. This study sought to determine the progression of myopia and axial elongation of children fitted with commercially available distance center soft multifocal contact lenses for 2 years. Eight- to eleven-year-old children with -1.00 D to -6.00 D spherical component and less than 1.00 D astigmatism were fitted with soft multifocal contact lenses with a +2.00 D add (Proclear Multifocal "D"; CooperVision, Fairport, NY). They were age- and gender-matched to participants from a previous study who were fitted with single-vision contact lenses (1 Day Acuvue; Vistakon, Jacksonville, FL). A-scan ultrasound and cycloplegic autorefraction were performed at baseline, after 1 year, and after 2 years. Multilevel modeling was used to compare the rate of change of myopia and axial length between single-vision and soft multifocal contact lens wearers. Forty participants were fitted with soft multifocal contact lenses, and 13 did not contribute complete data (5 contributed 1 year of data). The adjusted mean ± standard error spherical equivalent progression of myopia at 2 years was -1.03 ± 0.06 D for the single-vision contact lens wearers and -0.51 ± 0.06 for the soft multifocal contact lens wearers (p < 0.0001). The adjusted mean axial elongation was 0.41 ± 0.03 and 0.29 ± 0.03 for the single-vision and soft multifocal contact lens wearers, respectively (p < 0.0016). Soft multifocal contact lens wear resulted in a 50% reduction in the progression of myopia and a 29% reduction in axial elongation during the 2-year treatment period compared to a historical control group. Results from this and other investigations indicate a need for a long-term randomized clinical trial to investigate the potential for soft multifocal contact lens myopia control.

  5. Lens stem cells may reside outside the lens capsule: an hypothesis

    Directory of Open Access Journals (Sweden)

    Meyer Rita A

    2007-06-01

    Full Text Available Abstract In this paper, we consider the ocular lens in the context of contemporary developments in biological ideas. We attempt to reconcile lens biology with stem cell concepts and a dearth of lens tumors. Historically, the lens has been viewed as a closed system, in which cells at the periphery of the lens epithelium differentiate into fiber cells. Theoretical considerations led us to question whether the intracapsular lens is indeed self-contained. Since stem cells generate tumors and the lens does not naturally develop tumors, we reasoned that lens stem cells may not be present within the capsule. We hypothesize that lens stem cells reside outside the lens capsule, in the nearby ciliary body. Our ideas challenge the existing lens biology paradigm. We begin our discussion with lens background information, in order to describe our lens stem cell hypothesis in the context of published data. Then we present the ciliary body as a possible source for lens stem cells, and conclude by comparing the ocular lens with the corneal epithelium.

  6. Modern lens antennas for communications engineering

    CERN Document Server

    Thornton, John

    2012-01-01

    The aim of this book is to present the modern design principles and analysis of lens antennas. It gives graduates and RF/Microwave professionals the design insights in order to make full use of lens antennas.  Why do we want to write a book in lens antennas? Because this topic has not been thoroughly publicized, its importance is underestimated. As antennas play a key role in communication systems, recent development in wireless communications would indeed benefit from the characteristics of lens antennas: low profile, and low cost etc.  The major advantages of lens antennas are na

  7. Improving Children's Mental Health with a Digital Social Skills Development Game: A Randomized Controlled Efficacy Trial of Adventures aboard the S.S. GRIN.

    Science.gov (United States)

    Sanchez, Rebecca; Brown, Emily; Kocher, Kelly; DeRosier, Melissa

    2017-02-01

    The purpose of this study was to investigate whether a computer-based game to improve social skills and mental health in children with social skills deficits would be efficacious. The program, Adventures aboard the S.S. GRIN, translates a proven in-person intervention into a nine-episode interactive online adventure game that provides opportunity for knowledge acquisition and skill practice. Participants (children aged 7-11 years with social skills challenges) were randomly assigned to immediate treatment group (n = 33) or waitlist control group (n = 36). Children in the immediate treatment condition completed the game at home over the course of 9 weeks. Before playing the game and again within 1 week of game completion, children completed surveys about social literacy, social anxiety, bullying, social self-efficacy, and social satisfaction. Children who played Adventures improved significantly more from pretest to posttest than children who did not play the game in social literacy, social anxiety, bullying victimization, and social satisfaction. Online interactive games can be effective in improving mental health for children who struggle with social skills. For children who can access them, serious games have the potential to increase the reach of effective programs by overcoming the logistical and implementation barriers (such as cost, travel, and accessibility) that limit traditionally delivered mental health interventions.

  8. Analysis of the Expression and Polymorphism of APOE, HSP, BDNF, and GRIN2B Genes Associated with the Neurodegeneration Process in the Pathogenesis of Primary Open Angle Glaucoma

    Directory of Open Access Journals (Sweden)

    Alicja Nowak

    2015-01-01

    Full Text Available Glaucoma is characterized by optic neuropathy of the RGC or retinal nerve fiber. The aim of this study was to evaluate a relationship between the neurodegenerative genes’ polymorphisms of the APOE (rs449647, BDNF (rs2030324, GRIN2B (rs3764028, and HSP70-1 (rs1043618 and the occurrence risk of POAG and to investigate its effect on allele-specific gene expression. Genomic DNA was extracted from peripheral blood. Analysis of the genes’ polymorphisms was performed using PCR-RFLP. The level of mRNA expression was determined by QRT-PCR. We showed a statistically significant association of BDNF and APOE genes’ polymorphisms with a risk of POAG occurrence. There was a statistically significant association of the rs2030324 polymorphism with progression of POAG based on cup disc ratio value and rs1043618 polymorphism based on nerve fiber index and rim area. Furthermore, we found that mean HSP70-1 mRNA expression was significantly lower in the case of individuals with the G/G genotype than in the case of minor allele carriers, that is, G/C and C/C. We also found that BDNF and HSP70-1 expression level are associated with the progression of POAG based on rim area value. In conclusion, our results suggest that BDNF, APOE, and HSP70-1 genes might be associated with a risk of POAG occurrence in the Polish population.

  9. Analysis of the expression and polymorphism of APOE, HSP, BDNF, and GRIN2B genes associated with the neurodegeneration process in the pathogenesis of primary open angle glaucoma.

    Science.gov (United States)

    Nowak, Alicja; Majsterek, Ireneusz; Przybyłowska-Sygut, Karolina; Pytel, Dariusz; Szymanek, Katarzyna; Szaflik, Jerzy; Szaflik, Jacek P

    2015-01-01

    Glaucoma is characterized by optic neuropathy of the RGC or retinal nerve fiber. The aim of this study was to evaluate a relationship between the neurodegenerative genes' polymorphisms of the APOE (rs449647), BDNF (rs2030324), GRIN2B (rs3764028), and HSP70-1 (rs1043618) and the occurrence risk of POAG and to investigate its effect on allele-specific gene expression. Genomic DNA was extracted from peripheral blood. Analysis of the genes' polymorphisms was performed using PCR-RFLP. The level of mRNA expression was determined by QRT-PCR. We showed a statistically significant association of BDNF and APOE genes' polymorphisms with a risk of POAG occurrence. There was a statistically significant association of the rs2030324 polymorphism with progression of POAG based on cup disc ratio value and rs1043618 polymorphism based on nerve fiber index and rim area. Furthermore, we found that mean HSP70-1 mRNA expression was significantly lower in the case of individuals with the G/G genotype than in the case of minor allele carriers, that is, G/C and C/C. We also found that BDNF and HSP70-1 expression level are associated with the progression of POAG based on rim area value. In conclusion, our results suggest that BDNF, APOE, and HSP70-1 genes might be associated with a risk of POAG occurrence in the Polish population.

  10. Conjunctival impression cytology in contact lens wearers.

    Directory of Open Access Journals (Sweden)

    Simon Priya

    2002-01-01

    Full Text Available PURPOSE: To evaluate the cytological changes in conjunctiva following regular contact lens wear and to determine the correlation, if any, between severity of cytological alteration and symptoms related to contact lens wear. METHODS: One hundred eyes (50 normal asymptomatic subjects who served as a control group were studied by conjunctival impression cytology (CIC. These subjects were fitted with rigid gas permeable (RGP or soft contact lenses and were followed up at the end of 3 and 6 months. At each follow-up visit the CIC was repeated. A filter paper with the impression specimen was stained with periodic acid schiff (PAS and haematoxylin stain to study goblet cell loss. Papanicolaou stain was done to study squamous metaplasia. The cytological changes were graded using the system described by Natadisastra et al. RESULTS: Severity of cytological changes increased with the duration of contact lens wear (P = 0.00001. At the end of 6 months, 60% of symptomatic eyes wearing soft contact lens and RGP lens showed abnormal CIC changes. None of the asymptomatic RGP contact lens wearing eyes showed abnormal CIC changes whereas 33.4% of the asymptomatic soft contact lens wearing eyes showed abnormal CIC changes (P = 0.033. Epithelial changes occurred within 3-6 months of contact lens fitting. CONCLUSION: Severity of cytological changes increased with duration of lens wear (P = 0.00001. Prevalence and severity of cytological alteration is more in symptomatic contact lens wearers. Soft contact lens wearers although asymptomatic showed severe CIC changes.

  11. Mediating multimodal environmental knowledge across animation techniques

    DEFF Research Database (Denmark)

    Maier, Carmen Daniela

    2011-01-01

    in the technology- mediated discourse of short animation films. This is done by employing the model of multimodal discourse analysis proposed by Van Leeuwen (2008) and Machin and Van Leeuwen (2007) to the analysis of a series of animation films focused on environmental problems. These films are united under......://www.sustainlane.com/. The multimodal discourse analysis is meant to reveal how selection and representation of environmental knowledge about social actors, social actions, resources, time and space are influenced by animation techniques. Furthermore, in the context of this multimodal discourse analysis, their influence upon...

  12. Tibial cortical lesions: A multimodality pictorial review

    Energy Technology Data Exchange (ETDEWEB)

    Tyler, P.A., E-mail: philippa.tyler@rnoh.nhs.uk [Department of Radiology, Royal National Orthopaedic Hospital, Brockley Hill, Stanmore HA7 4LP (United Kingdom); Mohaghegh, P., E-mail: pegah1000@gmail.com [Department of Radiology, Royal National Orthopaedic Hospital, Brockley Hill, Stanmore HA7 4LP (United Kingdom); Foley, J., E-mail: jfoley1@nhs.net [Department of Radiology, Glasgow Royal Infirmary, 16 Alexandra Parade, Glasgow G31 2ES (United Kingdom); Isaac, A., E-mail: amandaisaac@doctors.org.uk [Department of Radiology, King' s College Hospital, Denmark Hill, London SE5 9RS (United Kingdom); Zavareh, A., E-mail: ali.zavareh@gmail.com [Department of Radiology, North Bristol NHS Trust, Frenchay, Bristol BS16 1LE (United Kingdom); Thorning, C., E-mail: cthorning@doctors.org.uk [Department of Radiology, East Surrey Hospital, Canada Avenue, Redhill, Surrey RH1 5RH (United Kingdom); Kirwadi, A., E-mail: anandkirwadi@gmail.com [Department of Radiology, Manchester Royal Infirmary, Oxford Road, Manchester M13 9WL (United Kingdom); Pressney, I., E-mail: ipressney@hotmail.com [Department of Radiology, Royal National Orthopaedic Hospital, Brockley Hill, Stanmore HA7 4LP (United Kingdom); Amary, F., E-mail: fernanda.amary@rnoh.nhs.uk [Department of Histopathology, Royal National Orthopaedic Hospital, Brockley Hill, Stanmore HA7 4LP (United Kingdom); Rajeswaran, G., E-mail: grajeswaran@gmail.com [Department of Radiology, Chelsea and Westminster Hospital, 369 Fulham Road, London SW10 9NH (United Kingdom)

    2015-01-15

    Highlights: • Multimodality imaging plays an important role in the investigation and diagnosis of shin pain. • We review the multimodality imaging findings of common cortically based tibial lesions. • We also describe the rarer pathologies of tibial cortical lesions. - Abstract: Shin pain is a common complaint, particularly in young and active patients, with a wide range of potential diagnoses and resulting implications. We review the natural history and multimodality imaging findings of the more common causes of cortically-based tibial lesions, as well as the rarer pathologies less frequently encountered in a general radiology department.

  13. The multimodal argumentation of persuasive counter discourses

    DEFF Research Database (Denmark)

    Maier, Carmen Daniela

    are given prominence in the argumentation by examining their complex interplay and functional differentiation. The ways in which speech, writing and images articulate the counter discourse occupy a central position in the analysis. A special focus is put on the multimodal configuration of specific...... and new multimodal ways of discussing them. References Kress, G. 2010. Multimodality. A Social Semiotic Approach to Contemporary Communication. London: Routledge. Van Leeuwen, Theo. 2008. Discourse and Practice. New Tools for Critical Discourse Analysis. Oxford: Oxford University Press. Chouliaraki, L...

  14. Photon correlations in multimode waveguides

    Energy Technology Data Exchange (ETDEWEB)

    Poem, Eilon; Silberberg, Yaron [Department of Physics of Complex Systems, Weizmann Institute of Science, Rehovot 76100 (Israel)

    2011-10-15

    We consider the propagation of classical and nonclassical light in multimode optical waveguides. We focus on the evolution of the few-photon correlation functions, which, much as the light-intensity distribution in such systems, evolve in a periodic manner, culminating in the ''revival'' of the initial correlation pattern at the end of each period. It is found that when the input state possesses nontrivial symmetries, the correlation revival period can be longer than that of the intensity, and thus the same intensity pattern can display different correlation patterns. We experimentally demonstrate this effect for classical, pseudothermal light, and compare the results with the predictions for nonclassical, quantum light.

  15. Multimode waveguide based directional coupler

    Science.gov (United States)

    Ahmed, Rajib; Rifat, Ahmmed A.; Sabouri, Aydin; Al-Qattan, Bader; Essa, Khamis; Butt, Haider

    2016-07-01

    The Silicon-on-Insulator (SOI) based platform overcomes limitations of the previous copper and fiber based technologies. Due to its high index difference, SOI waveguide (WG) and directional couplers (DC) are widely used for high speed optical networks and hybrid Electro-Optical inter-connections; TE00-TE01, TE00-TE00 and TM00-TM00 SOI direction couplers are designed with symmetrical and asymmetrical configurations to couple with TE00, TE01 and TM00 in a multi-mode semi-triangular ring-resonator configuration which will be applicable for multi-analyte sensing. Couplers are designed with effective index method and their structural parameters are optimized with consideration to coupler length, wavelength and polarization dependence. Lastly, performance of the couplers are analyzed in terms of cross-talk, mode overlap factor, coupling length and coupling efficiency.

  16. Multimodal integration in statistical learning

    DEFF Research Database (Denmark)

    Mitchell, Aaron; Christiansen, Morten Hyllekvist; Weiss, Dan

    2014-01-01

    Recent advances in the field of statistical learning have established that learners are able to track regularities of multimodal stimuli, yet it is unknown whether the statistical computations are performed on integrated representations or on separate, unimodal representations. In the present study......, we investigated the ability of adults to integrate audio and visual input during statistical learning. We presented learners with a speech stream synchronized with a video of a speaker’s face. In the critical condition, the visual (e.g., /gi/) and auditory (e.g., /mi/) signals were occasionally...... incongruent, which we predicted would produce the McGurk illusion, resulting in the perception of an audiovisual syllable (e.g., /ni/). In this way, we used the McGurk illusion to manipulate the underlying statistical structure of the speech streams, such that perception of these illusory syllables...

  17. Multimodal signalling in estrildid finches

    DEFF Research Database (Denmark)

    Gomes, A. C. R.; Funghi, C.; Soma, M.

    2017-01-01

    radiations, and one that includes many model species for research in sexual selection and communication. We found little evidence for either joint evolution or trade-offs between song and colour ornamentation. Some negative correlations between dance repertoire and song traits may suggest a functional...... compromise, but generally courtship dance also evolved independently from other signals. Instead of correlated evolution, we found that song, dance and colour are each related to different socio-ecological traits. Song complexity evolved together with ecological generalism, song performance with investment...... in reproduction, dance with commonness and habitat type, whereas colour ornamentation was shown previously to correlate mostly with gregariousness. We conclude that multimodal signals evolve in response to various socio-ecological traits, suggesting the accumulation of distinct signalling functions....

  18. Study on Titanium Nitride Film Modified for Intraocular Lens

    Institute of Scientific and Technical Information of China (English)

    2009-01-01

    Objective:To study the characteristics of the intraocular lens using ion beam sputtering depositing titanium nitride thin film on the intraocular lens(IOLs).Methods:To deposite titanium nitride thin film on the top of intraocular lens by ion beam sputtering depositing.We analyzed the surface morphology of intraocular lens through SEM and AFM.We detected intraocular lens resolution through the measurement of intraocular lens.Biocompatibility of intraocular lens is preliminary evaluated in this test.Results:T...

  19. Histology image search using multimodal fusion.

    Science.gov (United States)

    Caicedo, Juan C; Vanegas, Jorge A; Páez, Fabian; González, Fabio A

    2014-10-01

    This work proposes a histology image indexing strategy based on multimodal representations obtained from the combination of visual features and associated semantic annotations. Both data modalities are complementary information sources for an image retrieval system, since visual features lack explicit semantic information and semantic terms do not usually describe the visual appearance of images. The paper proposes a novel strategy to build a fused image representation using matrix factorization algorithms and data reconstruction principles to generate a set of multimodal features. The methodology can seamlessly recover the multimodal representation of images without semantic annotations, allowing us to index new images using visual features only, and also accepting single example images as queries. Experimental evaluations on three different histology image data sets show that our strategy is a simple, yet effective approach to building multimodal representations for histology image search, and outperforms the response of the popular late fusion approach to combine information.

  20. Intelligent Multimodal Signal Adaptation System Project

    Data.gov (United States)

    National Aeronautics and Space Administration — Micro Analysis and Design (MA&D) is pleased to submit this proposal to design an Intelligent Multimodal Signal Adaptation System. This system will dynamically...

  1. Multimode siloxane polymer components for optical interconnects

    Science.gov (United States)

    Bamiedakis, Nikolaos; Beals, Joseph, IV; Penty, Richard V.; White, Ian H.; DeGroot, Jon v., Jr.; Clapp, Terry V.; De Shazer, David

    2009-02-01

    This paper presents an overview of multimode waveguides and waveguide components formed from siloxane polymer materials which are suitable for use in optical interconnection applications. The components can be cost-effectively integrated onto conventional PCBs and offer increased functionality in optical transmission. The multimode waveguides exhibit low loss (0.04 dB/cm at 850 nm) and low crosstalk (benefit from the multimode nature of the waveguides allowing low loss combining (4 dB for an 8×1 device). A large range of power splitting ratios between 30% and 75% is achieved with multimode coupler devices. Examples of system applications benefiting from the use of these components are briefly presented including a terabit capacity optical backplane, a radio-over-fibre multicasting system and a SCM passive optical network.

  2. Mediating multimodal environmental knowledge across animation techniques

    DEFF Research Database (Denmark)

    Maier, Carmen Daniela

    2011-01-01

    The growing awareness of and concern about present environmental problems generate a proliferation of new forms of environmental discourses that are mediated in various ways. This chapter explores issues related to the ways in which environmental knowledge is multimodally communicated...... in the technology- mediated discourse of short animation films. This is done by employing the model of multimodal discourse analysis proposed by Van Leeuwen (2008) and Machin and Van Leeuwen (2007) to the analysis of a series of animation films focused on environmental problems. These films are united under......://www.sustainlane.com/. The multimodal discourse analysis is meant to reveal how selection and representation of environmental knowledge about social actors, social actions, resources, time and space are influenced by animation techniques. Furthermore, in the context of this multimodal discourse analysis, their influence upon...

  3. Multi-Modal Treatment of Nocturnal Enuresis.

    Science.gov (United States)

    Mohr, Caroline; Sharpley, Christopher F.

    1988-01-01

    The article reports a multimodal treatment of nocturnal enuresis and anxious behavior in a mildly mentally retarded woman. Behavioral treatment and removal of caffeine from the subject's diet eliminated both nocturnal enuresis and anxious behavior. (Author/DB)

  4. Lens Coupled Quantum Cascade Laser

    Science.gov (United States)

    Hu, Qing (Inventor); Lee, Alan Wei Min (Inventor)

    2013-01-01

    Terahertz quantum cascade (QC) devices are disclosed that can operate, e.g., in a range of about 1 THz to about 10 THz. In some embodiments, QC lasers are disclosed in which an optical element (e.g., a lens) is coupled to an output facet of the laser's active region to enhance coupling of the lasing radiation from the active region to an external environment. In other embodiments, terahertz amplifier and tunable terahertz QC lasers are disclosed.

  5. Fresnel Lens with Embedded Vortices

    Directory of Open Access Journals (Sweden)

    Sunil Vyas

    2012-01-01

    Full Text Available Vortices of different charges are embedded in a wavefront that has quadratic phase variation, and the intensity distribution near the focal plane is studied. This method may be useful in realizing complicated beam profiles. We have experimentally demonstrated the generation of vortex arrays having integer as well as fractional topological charges that produce different intensity profiles at the focal plane. The phase variation realized on a spatial light modulator (SLM acts as a Fresnel lens with embedded vortices.

  6. Engineering gestures for multimodal user interfaces

    OpenAIRE

    Echtler, Florian; Kammer, Dietrich; Vanacken, Davy; Hoste, Lode; Signer, Beat

    2014-01-01

    Despite increased presence of gestural and multimodal user interfaces in research as well as daily life, development of such systems still mostly relies on programming concepts which have emerged from classic WIMP user interfaces. This workshop proposes to explore the gap between attempts to formalize and structure development for multimodal interfaces in the research community on the one hand and the lack of adoption of these formal languages and frameworks by practitioners and other researc...

  7. Esthesioneuroblastoma: Multimodal management and review of literature

    Science.gov (United States)

    Kumar, Ritesh

    2015-01-01

    Esthesioneuroblastoma (ENB) is a rare malignant neoplasm arising from the olfactory neuroepithelium. ENB constitutes only 3% of all malignant intranasal neoplasm. Because of the rarity, the number of patients of ENB treated in individual departments is small. Most of these patients presents in locally advanced stages and require multimodality treatment in form of surgery, chemotherapy and radiotherapy. Multimodality approach with a risk-adapted strategy is required to achieve good control rates while minimizing treatment related toxicity. PMID:26380824

  8. Quantifying Quality Aspects of Multimodal Interactive Systems

    CERN Document Server

    Kühnel, Christine

    2012-01-01

    This book systematically addresses the quantification of quality aspects of multimodal interactive systems. The conceptual structure is based on a schematic view on human-computer interaction where the user interacts with the system and perceives it via input and output interfaces. Thus, aspects of multimodal interaction are analyzed first, followed by a discussion of the evaluation of output and input and concluding with a view on the evaluation of a complete system.

  9. Contact lens wear is intrinsically inflammatory.

    Science.gov (United States)

    Efron, Nathan

    2017-01-01

    Eye-care practitioners typically associate ocular inflammation during contact lens wear with serious complications such as microbial keratitis; however, more subtle mechanisms may be at play. This paper tests the notion that contact lens wear is intrinsically inflammatory by exploring whether uncomplicated contact lens wear meets the classical, clinical definition of inflammation - rubor (redness), calor (heat), tumor (swelling), dolor (pain) and functio laesa (loss of function) - as well as the contemporary, sub-clinical definition of inflammation (cellular and biochemical reactions). It is demonstrated that all of these clinical and sub-clinical criteria are met with hydrogel lens wear and most are met with silicone hydrogel lens wear, indicating that uncomplicated contact lens wear is intrinsically inflammatory. Consideration of both traditional and contemporary thinking about the role of inflammation in the human body leads to the perhaps surprising conclusion that the chronic, low grade, sub-clinical inflammatory status of the anterior eye during contact lens wear, which may be termed 'para-inflammation', is a positive, protective phenomenon, whereby up-regulation of the immune system, in a non-damaging way, maintains the eye in a state of 'heightened alert', ready to ward off any extrinsic noxious challenge. Characterisation of this inflammatory status may lead to the development of lens engineering or pharmacological strategies to modulate contact lens-induced inflammation, so as to render lens wear more safe and comfortable. © 2016 Optometry Australia.

  10. Multimode optical imaging of small animals: development and applications

    Science.gov (United States)

    Hwang, J. Y.; Moffatt-Blue, C.; Equils, O.; Fujita, M.; Jeong, J.; Khazenzon, N. M.; Lindsley, E.; Ljubimova, J.; Nowatzyk, A. G.; Farkas, D. L.; Wachsmann-Hogiu, S.

    2007-02-01

    We present an optical system for small animal imaging that can combine various in vivo imaging modalities, including fluorescence (intensity and lifetime), spectral, and trans-illumination imaging. This system consists of light-tight box with ultrafast pulsed or cw laser light excitation, motorized translational and rotational stages, a telecentric lens for detection, and a cooled CCD camera that can be coupled to an ultrafast time-gated intensifier. All components are modular, making possible laser excitation at various wavelengths and pulse lengths, and signal detection in a variety of ways (multimode). Results of drug nanoconjugate carrier delivery studies in mice are presented. Conventional and spectrally-resolved fluorescence images reveal details of in vivo drug nanoconjugate carrier accumulation within the tumor region and several organs in real time. By multi-spectral image analysis of ex vivo specimens from the same mice, we were able to evaluate the extent and topology of drug nanoconjugate carrier distribution into specific organs and the tumor itself.

  11. Multimodal pain stimulation of the gastrointestinal tract

    Institute of Scientific and Technical Information of China (English)

    Asbjφrn Mohr Drewes; Hans Gregersen

    2006-01-01

    Understanding and characterization of pain and other sensory symptoms are among the most important issues in the diagnosis and assessment of patient with gastrointestinal disorders. Methods to evoke and assess experimental pain have recently developed into a new area with the possibility for multimodal stimulation (e.g.,electrical, mechanical, thermal and chemical stimulation)of different nerves and pain pathways in the human gut. Such methods mimic to a high degree the pain experienced in the clinic. Multimodal pain methods have increased our basic understanding of different peripheral receptors in the gut in health and disease. Together with advanced muscle analysis, the methods have increased our understanding of receptors sensitive to mechanical,chemical and temperature stimuli in diseases, such as systemic sclerosis and diabetes. The methods can also be used to unravel central pain mechanisms, such as those involved in allodynia, hyperalgesia and referred pain. Abnormalities in central pain mechanisms are often seen in patients with chronic gut pain and hence methods relying on multimodal pain stimulation may help to understand the symptoms in these patients.Sex differences have been observed in several diseases of the gut, and differences in central pain processing between males and females have been hypothesized using multimodal pain stimulations. Finally, multimodal methods have recently been used to gain more insight into the effect of drugs against pain in the GI tract.Hence, the multimodal methods undoubtedly represents a major step forward in the future characterization and treatment of patients with various diseases of the gut.

  12. Generalized modulational instability in multimode fibers: wideband multimode parametric amplification

    CERN Document Server

    Guasoni, M

    2015-01-01

    In this paper intermodal modulational instability (IM-MI) is analyzed in a multimode fiber where several spatial and polarization modes propagate. The coupled nonlinear Schr\\"{o}dinger equations describing the modal evolution in the fiber are linearized and reduced to an eigenvalue problem. As a result, the amplification of each mode can be described by means of the eigenvalues and eigenvectors of a matrix that stores the information about the dispersion properties of the modes and the modal power distribution of the pump. Some useful analytical formulas are also provided that estimate the modal amplification as function of the system parameters. Finally, the impact of third-order dispersion and of absorbtion losses is evaluated, which reveals some surprising phenomena into the IM-MI dynamics. These outcomes generalize previous studies on bimodal-MI, related to the interaction between 2 spatial or polarization modes, to the most general case of $N>2$ interacting modes. Moreover, they pave the way towards the ...

  13. Evolution of a pre and post lens tear film with a contact lens

    Science.gov (United States)

    Gerhart, Matthew; Anderson, Daniel

    2012-11-01

    The work is the development, implementation, and analysis of a two-dimensional tear film model including a porous contact lens. The geometry of the problem is: a pre-lens layer that is a thin tear film between the outside air and contact lens, a contact lens that is a rigid but movable porous substrate, and a post-lens layer that is a thin film layer between the contact lens and the cornea. We are looking at short and long term behavior of the evolution of the thin film in the pre-lens layer coupled with the porous layer and the thin squeeze film in the post-lens layer. We model the different behaviors that arise as the Darcy number, evaporation effects, and boundary flux conditions change.

  14. Lateral shear interferometry with holo shear lens

    Science.gov (United States)

    Joenathan, C.; Mohanty, R. K.; Sirohi, R. S.

    1984-12-01

    A simple method for obtaining lateral shear using holo shear lenses (HSL) has been discussed. This simple device which produces lateral shears in the orthogonal directions has been used for lens testing. The holo shear lens is placed at or near the focus of the lens to be tested. It has also been shown that HSL can be used in speckle shear interferometry as it performs both the functions of shearing and imaging.

  15. An inverse and analytic lens design method

    OpenAIRE

    Lu, Yang; Lakshminarayanan, Vasudevan

    2016-01-01

    Traditional lens design is a numerical and forward process based on ray tracing and aberration theory. This method has limitations because the initial configuration of the lens has to be specified and the aberrations of the lenses have to considered. This paper is an initial attempt to investigate an analytic and inverse lens design method, called Lagrange, to overcome these barriers. Lagrange method tries to build differential equations in terms of the system parameters and the system input ...

  16. GRIN3B missense mutation as an inherited risk factor for schizophrenia: whole-exome sequencing in a family with a familiar history of psychotic disorders.

    Science.gov (United States)

    Hornig, Tobias; Grüning, Björn; Kundu, Kousik; Houwaart, Torsten; Backofen, Rolf; Biber, Knut; Normann, Claus

    2017-01-30

    Glutamate is the most important excitatory neurotransmitter in the brain. The N-methyl-D-aspartate (NMDA) receptor is a glutamate-gated ionotropic cation channel that is composed of several subunits and modulated by a glycine binding site. Many forms of synaptic plasticity depend on the influx of calcium ions through NMDA receptors, and NMDA receptor dysfunction has been linked to a number of neuropsychiatric disorders, including schizophrenia. Whole-exome sequencing was performed in a family with a strong history of psychotic disorders over three generations. We used an iterative strategy to obtain condense and meaningful variants. In this highly affected family, we found a frameshift mutation (rs10666583) in the GRIN3B gene, which codes for the GluN3B subunit of the NMDA receptor in all family members with a psychotic disorder, but not in the healthy relatives. Matsuno et al., also reported this null variant as a risk factor for schizophrenia in 2015. In a broader sample of 22 patients with psychosis, the allele frequency of the rs10666583 mutation variant was increased compared to those of healthy population samples and unaffected relatives. Compared to the 1000 Genomes Project population, we found a significant increase of this variant with a large effect size among patients. The amino acid shift degrades the S1/S2 glycine binding domain of the dominant modulatory GluN3B subunit of the NMDA receptor, which subsequently affects the permeability of the channel pore to calcium ions. A decreased glycine affinity for the GluN3B subunit might cause impaired functional capability of the NMDA receptor and could be an important risk factor for the pathogenesis of psychotic disorders.

  17. Algorithm design of liquid lens inspection system

    Science.gov (United States)

    Hsieh, Lu-Lin; Wang, Chun-Chieh

    2008-08-01

    In mobile lens domain, the glass lens is often to be applied in high-resolution requirement situation; but the glass zoom lens needs to be collocated with movable machinery and voice-coil motor, which usually arises some space limits in minimum design. In high level molding component technology development, the appearance of liquid lens has become the focus of mobile phone and digital camera companies. The liquid lens sets with solid optical lens and driving circuit has replaced the original components. As a result, the volume requirement is decreased to merely 50% of the original design. Besides, with the high focus adjusting speed, low energy requirement, high durability, and low-cost manufacturing process, the liquid lens shows advantages in the competitive market. In the past, authors only need to inspect the scrape defect made by external force for the glass lens. As to the liquid lens, authors need to inspect the state of four different structural layers due to the different design and structure. In this paper, authors apply machine vision and digital image processing technology to administer inspections in the particular layer according to the needs of users. According to our experiment results, the algorithm proposed can automatically delete non-focus background, extract the region of interest, find out and analyze the defects efficiently in the particular layer. In the future, authors will combine the algorithm of the system with automatic-focus technology to implement the inside inspection based on the product inspective demands.

  18. A Magnification Lens for Interactive Volume Visualization

    Energy Technology Data Exchange (ETDEWEB)

    LaMar, E; Hamann, B; Joy, K I

    2001-07-19

    Volume visualization of large data sets suffers from the same problem that many other visualization modalities suffer from: either one can visualize the entire data set and lose small details or visualize a small region and lose the context. In this paper, they present a magnification lens technique for volume visualization. While the notion of a magnification-lens is not new, and other techniques attempt to simulate the physical properties of a magnifying lens, their contribution is in developing a magnification lens that is fast, can be implemented using a fairly small software overhead, and has a natural, intuitive appearance. The issue with magnification lens is the border, or transition, region. The lens center and exterior have a constant zoom factor, and are simple to render. It is the border region that blends between the external and interior magnification, and has a non-constant magnification. They use the perspective-correct textures capability, available in most current graphics systems, to produce a lens with a tessellated border region that approximates linear compression with respect to the radius of the magnification lens. They discuss how a cubic border can mitigate the discontinuities resulting from the use of a linear function, without significant performance loss. They discuss various issues concerning development of a three-dimensional magnification lens.

  19. Trends of contact lens prescribing in Jordan.

    Science.gov (United States)

    Haddad, Mera F; Bakkar, May; Gammoh, Yazan; Morgan, Philip

    2016-10-01

    To evaluate contact lens prescribing trends among optometrists in Jordan. Optometrists from 173 practices in Jordan were surveyed about prescribing contact lenses in their practice. Practitioners were required to record information for the last 10 patients that visited their practice. Demographic data such as age and gender was obtained for each patient. In addition, data relating to lens type, lens design, replacement methods and the care regime advised to each patient were recorded. Practitioners were required to provide information relating to their education and years of experience. The influence of education and experience with respect to lens prescribing trends was explored using linear regression models for the proportions of lens types fitted for patients. A total of 1730 contact lens fits were analyzed. The mean (±SD) age of lens wearers was 26.6 (±7.9) years, of whom 65% were female. Conventional hydrogel lenses were the most prescribed lenses, accounting for 60.3% of the fits, followed by silicone hydrogel lenses (31.3%), and rigid lenses (8.4%). In terms of lens design, spherical lenses appeared to be most commonly prescribed on monthly basis. Daily disposable lenses were second most prescribed lens modality, accounting for 20.4% of the study sample. Multi-purpose solution (MPS) was the preferred care regimen, with a prevalence of 88.1% reported in the study sample, compared to hydrogen peroxide (1-step and 2-step), which represented only 2.8% of the patients in this study. A relationship was established between the two educational groups for rigid lens prescribing (F=17.4, ptrends among optometrists in Jordan. Contact lens prescribing in terms of lens type, lens design, modality of wear and care regimen agree with global market trends with small variations. This report will help practitioners and the industry to detect any deficiencies in the contact lens market in Jordan, which will ease implementing current and future plans in developing contact

  20. Coculture with intraocular lens material-activated macrophages induces an inflammatory phenotype in lens epithelial cells.

    Science.gov (United States)

    Pintwala, Robert; Postnikoff, Cameron; Molladavoodi, Sara; Gorbet, Maud

    2015-03-01

    Cataracts are the leading cause of blindness worldwide, requiring surgical implantation of an intraocular lens. Despite evidence of leukocyte ingress into the postoperative lens, few studies have investigated the leukocyte response to intraocular lens materials. A novel coculture model was developed to examine macrophage activation by hydrophilic acrylic (poly(2-hydroxyethyl methacrylate)) and hydrophobic acrylic (polymethylmethacrylate) commercial intraocular lens. The human monocytic cell line THP-1 was differentiated into macrophages and cocultured with human lens epithelial cell line (HLE-B3) with or without an intraocular lens for one, two, four, or six days. Using flow cytometry and confocal microscopy, expression of the macrophage activation marker CD54 (intercellular adhesion molecule-1) and production of reactive oxygen species via the fluorogenic probe 2',7'-dichlorodihydrofluorescein diacetate were examined in macrophages. α-Smooth muscle actin, a transdifferentiation marker, was characterized in lens epithelial cells. The poly(2-hydroxyethyl methacrylate) intraocular lens prevented adhesion but induced significant macrophage activation (p intraocular lens), while the polymethylmethacrylate intraocular lens enabled adhesion and multinucleated fusion, but induced no significant activation. Coculture with either intraocular lens increased reactive oxygen species production in macrophages after one day (p intraocular lens, with hydrophilic surfaces inducing higher activation than hydrophobic surfaces. These findings provide a new method of inquiry into uveal biocompatibility, specifically through the quantification of cell-surface markers of leukocyte activation.

  1. Multimodal analgesia and regional anaesthesia.

    Science.gov (United States)

    Tornero Tornero, C; Fernández Rodríguez, L E; Orduña Valls, J

    Multimodal analgesia provides quality analgesia, with fewer side effects due to the use of combined analgesics or analgesic techniques. Regional anaesthesia plays a fundamental role in achieving this goal. The different techniques of regional anaesthesia that include both peripheral and central blocks in either a single dose or in continuous infusion help to modulate the nociceptive stimuli that access the central level. The emergence of the ultrasound as an effective system to perform regional anaesthesia techniques has allowed the development of new regional anaesthesia techniques that formerly could not be carried out since only neurostimulation or skin references were used. It is essential to take into account that even with effective blocking it is advisable to associate other drugs by other routes, in this way we will be able to reduce the required doses individually and attempt to achieve a synergistic, not purely additive, effect. Copyright © 2017 Sociedad Española de Anestesiología, Reanimación y Terapéutica del Dolor. Publicado por Elsevier España, S.L.U. All rights reserved.

  2. Multimodality Management of Trigeminal Schwannomas.

    Science.gov (United States)

    Niranjan, Ajay; Barnett, Samuel; Anand, Vijay; Agazzi, Siviero

    2016-08-01

    Patients presenting with trigeminal schwannomas require multimodality management by a skull base surgical team that can offer expertise in both transcranial and transnasal approaches as well as radiosurgical and microsurgical strategies. Improvement in neurologic symptoms, preservation of cranial nerve function, and control of mass effect are the primary goals of management for trigeminal schwannomas. Complete surgical resection is the treatment of choice but may not be possible in all cases. Radiosurgery is an option as primary management for small- to moderate-sized tumors and can be used for postoperative residuals or recurrences. Planned surgical resection followed by SRS for residual tumor is an effective option for larger trigeminal schwannomas. The endoscopic resection is an excellent approach for patients with an extradural tumor or tumors isolated to the Meckel cave. A detailed analysis of a tumor and its surroundings based on high-quality imaging can help better estimate the expected outcome from each treatment. An expert skull base team should be able to provide precise counseling for each patient's situation for selecting the best option.

  3. Miniature multimode monolithic flextensional transducers.

    Science.gov (United States)

    Hladky-Hennion, Anne-Christine; Uzgur, A Erman; Markley, Douglas C; Safari, Ahmad; Cochran, Joe K; Newnham, Robert E

    2007-10-01

    Traditional flextensional transducers classified in seven groups based on their designs have been used extensively in 1-100 kHz range for mine hunting, fish finding, oil explorations, and biomedical applications. In this study, a new family of small, low cost underwater, and biomedical transducers has been developed. After the fabrication of transducers, finite-elements analysis (FEA) was used extensively in order to optimize these miniature versions of high-power, low-frequency flextensional transducer designs to achieve broad bandwidth for both transmitting and receiving, engineered vibration modes, and optimized acoustic directivity patterns. Transducer topologies with various shapes, cross sections, and symmetries can be fabricated through high-volume, low-cost ceramic and metal extrusion processes. Miniaturized transducers posses resonance frequencies in the range of above 1 MHz to below 10 kHz. Symmetry and design of the transducer, polling patterns, driving and receiving electrode geometries, and driving conditions have a strong effect on the vibration modes, resonance frequencies, and radiation patterns. This paper is devoted to small, multimode flextensional transducers with active shells, which combine the advantages of small size and low-cost manufacturing with control of the shape of the acoustic radiation/receive pattern. The performance of the transducers is emphasized.

  4. Paediatric intraocular lens implants: accuracy of lens power calculations.

    Science.gov (United States)

    O'Gallagher, M K; Lagan, M A; Mulholland, C P; Parker, M; McGinnity, G; McLoone, E M

    2016-09-01

    PurposeThis study aims to evaluate the accuracy of lens prediction formulae on a paediatric population.MethodsA retrospective case-note review was undertaken of patients under 8 years old who underwent cataract surgery with primary lens implantation in a regional referral centre for paediatric ophthalmology, excluding those whose procedure was secondary to trauma. Biometric and refractive data were analysed for 43 eyes, including prediction errors (PE). Statistical measures used included mean absolute error (MAE), median absolute error (MedAE), Student's t-test and Lin's correlation coefficient.ResultsThe mean PE using the SRK-II formula was +0.96 D (range -2.47D to +2.41 D, SD 1.33 D, MAE 1.38 D, MedAE 1.55, n=15). The mean PE was smaller using SRK/T (-0.18 D, range -3.25 D to +3.95 D, SD 1.70 D, MAE 1.30 D, MedAE 1.24, n=27). We performed an analysis of the biometry data using four different formula (Hoffer Q, Holladay 1, SRK-II and SRK/T). Hoffer Q showed a smaller MedAE than other formulae but also a myopic bias.ConclusionOur clinical data suggest SRK/T was more accurate in predicting post-operative refraction in this cohort of paediatric patients undergoing cataract surgery. Hoffer Q may have improved accuracy further.

  5. Flat lens for seismic waves

    CERN Document Server

    Brule, Stephane; Guenneau, Sebastien

    2016-01-01

    A prerequisite for achieving seismic invisibility is to demonstrate the ability of civil engineers to control seismic waves with artificially structured soils. We carry out large-scale field tests with a structured soil made of a grid consisting of cylindrical and vertical holes in the ground and a low frequency artificial source (< 10 Hz). This allows the identification of a distribution of energy inside the grid, which can be interpreted as the consequence of an effective negative refraction index. Such a flat lens reminiscent of what Veselago and Pendry envisioned for light opens avenues in seismic metamaterials to counteract the most devastating components of seismic signals.

  6. Atom lens without chromatic aberrations

    CERN Document Server

    Efremov, Maxim A; Schleich, Wolfgang P

    2012-01-01

    We propose a lens for atoms with reduced chromatic aberrations and calculate its focal length and spot size. In our scheme a two-level atom interacts with a near-resonant standing light wave formed by two running waves of slightly different wave vectors, and a far-detuned running wave propagating perpendicular to the standing wave. We show that within the Raman-Nath approximation and for an adiabatically slow atom-light interaction, the phase acquired by the atom is independent of the incident atomic velocity.

  7. Intraocular lens with accommodation capacity

    OpenAIRE

    Dorronsoro, Carlos; Alejandre, Nicolás; Bekesi, Nandor; Marcos, Susana

    2014-01-01

    Intraocular lens with accommodation capacity comprising a first optical member (1) having a dynamic optical power, to which a second optical member (2) with a fixed optical power is affixed, in such a manner that at least a central part of each of one of one of the curved surfaces (2a, 2b) of the second optical member (2) and of at least one of the surfaces (1a, 1b) of the first optical member (1) are in contact with each other, the second optical member (2) and the first optical member (1) p...

  8. Squeezing Properties of the Generalized Multimode Squeezed States

    Institute of Scientific and Technical Information of China (English)

    SONGTong-Qiang

    2001-01-01

    By means of the invariance of Weyl ordering under similar transformations we derive the explicit form of the generalized multimode squeezed states.Moreover,the completeness relation and the squeezing properties of the generalized multimode squeezed states are discussed.

  9. Squeezing Properties of the Generalized Multimode Squeezed States

    Institute of Scientific and Technical Information of China (English)

    SONG Tong-Qiang

    2001-01-01

    By means of the invariance of Weyl ordering under similar transformations we derive the explicit form of the generalized multimode squeezed states. Moreover, the completeness relation and the squeezing properties of the generalized multimode squeezed states are discussed.

  10. Single LP(0,n) mode excitation in multimode fibers.

    Science.gov (United States)

    Bhatia, Nitin; Rustagi, Kailash C; John, Joseph

    2014-07-14

    We analyze the transmission of a Single mode - Multimode -Multimode (SMm) fiber structure with the aim of exciting a single radial mode in the second multimode fiber. We show that by appropriate choice of the length of the central multimode fiber one can obtain > 90% of the total core power in a chosen mode. We also discuss methods of removing undesirable cladding and radiation modes and estimate tolerances for practical applications.

  11. Multimodale trafiknet i GIS (Multimodal Traffic Network in GIS)

    DEFF Research Database (Denmark)

    Kronbak, Jacob; Brems, Camilla Riff

    1996-01-01

    The report introduces the use of multi-modal traffic networks within a geographical Information System (GIS). The necessary theory of modelling multi-modal traffic network is reviewed and applied to the ARC/INFO GIS by an explorative example.......The report introduces the use of multi-modal traffic networks within a geographical Information System (GIS). The necessary theory of modelling multi-modal traffic network is reviewed and applied to the ARC/INFO GIS by an explorative example....

  12. Contact lens intolerance: refitting with dual axis lens for corneal refractive therapy

    Science.gov (United States)

    López-López, María; Pelegrín-Sánchez, José Miguel; Sobrado-Calvo, Paloma; García-Ayuso, Diego

    2011-01-01

    Corneal refractive therapy is a non-surgical procedure whose main purpose is to improve uncorrected visual acuity during the day, without spectacles or contact lenses. We report an adult woman who shows contact lens intolerance and does not want to wear eyeglasses. We used dual axis contact lens to improve lens centration. We demonstrate a maintained unaided visual acuity during one year of treatment. In conclusion, we can consider refitting with dual axis lens for corneal refractive therapy as a non-surgical option for patients who show contact lens intolerance.

  13. Fabricating customized hydrogel contact lens

    Science.gov (United States)

    Childs, Andre; Li, Hao; Lewittes, Daniella M.; Dong, Biqin; Liu, Wenzhong; Shu, Xiao; Sun, Cheng; Zhang, Hao F.

    2016-10-01

    Contact lenses are increasingly used in laboratories for in vivo animal retinal imaging and pre-clinical studies. The lens shapes often need modification to optimally fit corneas of individual test subjects. However, the choices from commercially available contact lenses are rather limited. Here, we report a flexible method to fabricate customized hydrogel contact lenses. We showed that the fabricated hydrogel is highly transparent, with refractive indices ranging from 1.42 to 1.45 in the spectra range from 400 nm to 800 nm. The Young’s modulus (1.47 MPa) and hydrophobicity (with a sessile drop contact angle of 40.5°) have also been characterized experimentally. Retinal imaging using optical coherence tomography in rats wearing our customized contact lenses has the quality comparable to the control case without the contact lens. Our method could significantly reduce the cost and the lead time for fabricating soft contact lenses with customized shapes, and benefit the laboratorial-used contact lenses in pre-clinical studies.

  14. Plasma Lens for Muon and Neutrino Beams

    Energy Technology Data Exchange (ETDEWEB)

    Kahn,S.A.; Korenev, S.; Bishai, M.; Diwan, M.; Gallardo, J.C.; Hershcovitch, A.; Johnson, B.M.

    2008-06-23

    The plasma lens is examined as an alternate to focusing horns and solenoids for use in a neutrino or muon beam facility. The plasma lens concept is based on a combined high-energy lens/target configuration. The current is fed at electrodes located upstream and downstream from the target where pion capturing is needed. The current flows primarily in the plasma, which has a lower resistivity than the target. A second plasma lens section, with an additional current feed, follows the target to provide shaping of the plasma for optimum focusing. The plasma lens is immersed in an additional solenoid magnetic field to facilitate the plasma stability. The geometry of the plasma is shaped to provide optimal pion capture. Simulations of this plasma lens system have shown a 25% higher neutrino production than the horn system. Plasma lenses have the additional advantage of negligible pion absorption and scattering by the lens material and reduced neutrino contamination during anti-neutrino running. Results of particle simulations using plasma lens will be presented.

  15. Liquid lens using acoustic radiation force.

    Science.gov (United States)

    Koyama, Daisuke; Isago, Ryoichi; Nakamura, Kentaro

    2011-03-01

    A liquid lens is proposed that uses acoustic radiation force with no mechanical moving parts. It consists of a cylindrical acrylic cell filled with two immiscible liquids (degassed water and silicone oil) and a concave ultrasound transducer. The focal point of the transducer is located on the oil-water interface, which functions as a lens. The acoustic radiation force is generated when there is a difference in the acoustic energy densities of different media. An acoustic standing wave was generated in the axial direction of the lens and the variation of the shape of the oil-water interface was observed by optical coherence tomography (OCT). The lens profile can be rapidly changed by varying the acoustic radiation force from the transducer. The kinematic viscosity of silicone oil was optimized to minimize the response times of the lens. Response times of 40 and 80 ms when switching ultrasonic radiation on and off were obtained with a kinematic viscosity of 200 cSt. The path of a laser beam transmitted through the lens was calculated by ray-tracing simulations based on the experimental results obtained by OCT. The transmitted laser beam could be focused by applying an input voltage. The liquid lens could be operated as a variable-focus lens by varying the input voltage.

  16. Metasurface lens: Shrinking the camera size

    Science.gov (United States)

    Sun, Cheng

    2017-01-01

    A miniaturized camera has been developed by integrating a planar metasurface lens doublet with a CMOS image sensor. The metasurface lens doublet corrects the monochromatic aberration and thus delivers nearly diffraction-limited image quality over a wide field of view.

  17. Managing as designing with a positive lens

    NARCIS (Netherlands)

    Avital, M.; Boland, R.J.; Avital, M.; Boland, R.J.; Cooperrider, D.L.

    2007-01-01

    The role and potential contribution of a positive lens to the design of systems and organizations is the focus of this essay. The positive lens refers to an emerging perspective in the social sciences that emphasizes a positive stance toward our capacity to construct better organizations and technol

  18. Optimization of Zoom Lens with Discrete State of Liquid Lens Elements by Using Genetic Algorithm

    Directory of Open Access Journals (Sweden)

    Cheng-Mu Tsai

    2015-01-01

    Full Text Available This paper is to employ liquid lens elements to design a lens with zoom function by using the genetic algorithm (GA optimization. The liquid lens elements used in the proposal can apply voltage adjustment to generate the electrical field that induces the liquid with electric conductivity to vary the surface curvature between two different kinds of liquids. According to the voltage level, the liquid lens element makes the discrete variation of the curvature and thickness realize the zoom function without moving the lens groups so that the overall length can be reduced. However, it is difficult to design the zoom lens under the discrete variation of the curvature and thickness in the liquid lens elements and the mechanical space that is constantly limited. The GA offers a flexible way for lens optimization. We regarded the spot size as the fitness function to look for the optimum curvatures, thickness, and the corresponding statuses of liquid lens elements for the zoom lens. As a result, the zoom lens with constant space can be realized by running the selection, crossover, and mutation operation in the GA optimization.

  19. Reference Resolution in Multi-modal Interaction: Position paper

    NARCIS (Netherlands)

    Fernando, T.; Nijholt, Antinus

    2002-01-01

    In this position paper we present our research on multimodal interaction in and with virtual environments. The aim of this presentation is to emphasize the necessity to spend more research on reference resolution in multimodal contexts. In multi-modal interaction the human conversational partner can

  20. Reference resolution in multi-modal interaction: Preliminary observations

    NARCIS (Netherlands)

    González González, G.R.; Nijholt, Antinus

    2002-01-01

    In this paper we present our research on multimodal interaction in and with virtual environments. The aim of this presentation is to emphasize the necessity to spend more research on reference resolution in multimodal contexts. In multi-modal interaction the human conversational partner can apply

  1. Reference resolution in multi-modal interaction: Preliminary observations

    NARCIS (Netherlands)

    Nijholt, A.; González González, G.R.

    2002-01-01

    In this paper we present our research on multimodal interaction in and with virtual environments. The aim of this presentation is to emphasize the necessity to spend more research on reference resolution in multimodal contexts. In multi-modal interaction the human conversational partner can apply mo

  2. [Multimodal pain therapy: principles and indications].

    Science.gov (United States)

    Arnold, B; Brinkschmidt, T; Casser, H-R; Gralow, I; Irnich, D; Klimczyk, K; Müller, G; Nagel, B; Pfingsten, M; Schiltenwolf, M; Sittl, R; Söllner, W

    2009-04-01

    Multimodal pain therapy describes an integrated multidisciplinary treatment in small groups with a closely coordinated therapeutical approach. Somatic and psychotherapeutic procedures cooperate with physical and psychological training programs. For chronic pain syndromes with complex somatic, psychological and social consequences, a therapeutic intensity of at least 100 hours is recommended. Under these conditions multimodal pain therapy has proven to be more effective than other kinds of treatment. If monodisciplinary and/or outpatient therapies fail, health insurance holders have a legitimate claim to this form of therapy.Medical indications are given for patients with chronic pain syndromes, but also if there is an elevated risk of chronic pain in the early stadium of the disease and aiming at delaying the process of chronification. Relative contraindications are a lack of motivation for behavioural change, severe mental disorders or psychopathologies and addiction problems. The availability of multimodal pain treatment centers in Germany is currently insufficient.

  3. Instrumentation challenges in multi-modality imaging

    Energy Technology Data Exchange (ETDEWEB)

    Brasse, D., E-mail: david.brasse@iphc.cnrs.fr [Institut Pluridisciplinaire Hubert Curien, Université de Strasbourg, 23 rue du Loess 67037 Strasbourg (France); CNRS, UMR7178, 67037 Strasbourg (France); Boisson, F. [Institut Pluridisciplinaire Hubert Curien, Université de Strasbourg, 23 rue du Loess 67037 Strasbourg (France); CNRS, UMR7178, 67037 Strasbourg (France)

    2016-02-11

    Based on different physical principles, imaging procedures currently used in both clinical and preclinical applications present different performance that allow researchers to achieve a large number of studies. However, the relevance of obtaining a maximum of information relating to the same subject is undeniable. The last two decades have thus seen the advent of a full-fledged research axis, the multimodal in vivo imaging. Whether from an instrumentation point of view, for medical research or the development of new probes, all these research works illustrate the growing interest of the scientific community for multimodal imaging, which can be approached with different backgrounds and perspectives from engineers to end-users point of views. In the present review, we discuss the multimodal imaging concept, which focuses not only on PET/CT and PET/MRI instrumentation but also on recent investigations of what could become a possible future in the field.

  4. Multimodality Data Integration in Epilepsy

    Directory of Open Access Journals (Sweden)

    Otto Muzik

    2007-01-01

    Full Text Available An important goal of software development in the medical field is the design of methods which are able to integrate information obtained from various imaging and nonimaging modalities into a cohesive framework in order to understand the results of qualitatively different measurements in a larger context. Moreover, it is essential to assess the various features of the data quantitatively so that relationships in anatomical and functional domains between complementing modalities can be expressed mathematically. This paper presents a clinically feasible software environment for the quantitative assessment of the relationship among biochemical functions as assessed by PET imaging and electrophysiological parameters derived from intracranial EEG. Based on the developed software tools, quantitative results obtained from individual modalities can be merged into a data structure allowing a consistent framework for advanced data mining techniques and 3D visualization. Moreover, an effort was made to derive quantitative variables (such as the spatial proximity index, SPI characterizing the relationship between complementing modalities on a more generic level as a prerequisite for efficient data mining strategies. We describe the implementation of this software environment in twelve children (mean age 5.2±4.3 years with medically intractable partial epilepsy who underwent both high-resolution structural MR and functional PET imaging. Our experiments demonstrate that our approach will lead to a better understanding of the mechanisms of epileptogenesis and might ultimately have an impact on treatment. Moreover, our software environment holds promise to be useful in many other neurological disorders, where integration of multimodality data is crucial for a better understanding of the underlying disease mechanisms.

  5. Bacterial assay of contact lens wearers.

    Science.gov (United States)

    Hart, D E; Hosmer, M; Georgescu, M; Farris, R L

    1996-03-01

    The goal of the project was to determine the quantity of bacteria on the contact lens and adjacent areas of the eye. This paper is a quantitative study of the contact lens and ocular aerobic microbiota in a mixed group of daily and extended wear disposable contact lens users. The contact lens, the lower fornix, tears collecting at the lower fornix, and edge of the lower lid at the Meibomian gland margin were assayed for the quantity of bacterial colony forming units (CFU). Eighteen patients wearing 49 disposable high water content hydrogel contact lenses were assayed and the mean lens age was 8.8 +/- 4.6 days. Three patients wore their lenses on a daily wear basis and 15 on an extended wear schedule. Tear samples were obtained with sterile microbial loops and the lens was macerated into small particles with a tissue grinder. The samples were poured onto the surface of chocolate agar plates and incubated at 35 degrees C for 48 h in 5% Co2. The lid margin revealed the greatest bacterial presence (mean = 9.7 CFU; median = 2 CFU; mode = 0 CFU). The lens showed the next greatest presence of CFU (mean = 4.5 CFU; median = 1 CFU; mode = 0). The fornix and tears revealed the least bacterial presence (fornix: mean = 2.6 CFU; median = 0 CFU; mode = 0 CFU). The bacteria were coagulase-negative staphylococci. The bacterial assay of disposable lens wearing contact lens subjects indicates that the lid margins are the greatest source of bacteria with the tears being the lowest. These studies support the concept that in the eye, the lens typically does not possess a large number of bacteria under normal conditions.

  6. Multimodal surveillance sensors, algorithms, and systems

    CERN Document Server

    Zhu, Zhigang

    2007-01-01

    From front-end sensors to systems and environmental issues, this practical resource guides you through the many facets of multimodal surveillance. The book examines thermal, vibration, video, and audio sensors in a broad context of civilian and military applications. This cutting-edge volume provides an in-depth treatment of data fusion algorithms that takes you to the core of multimodal surveillance, biometrics, and sentient computing. The book discusses such people and activity topics as tracking people and vehicles and identifying individuals by their speech.Systems designers benefit from d

  7. Detecting multimode entanglement by symplectic uncertainty relations

    CERN Document Server

    Serafini, A

    2005-01-01

    Quantities invariant under symplectic (i.e. linear and canonical) transformations are constructed as functions of the second moments of N pairs of bosonic field operators. A general multimode uncertainty relation is derived as a necessary constraint on such symplectic invariants. In turn, necessary conditions for the separability of multimode continuous variable states under (MxN)-mode bipartitions are derived from the uncertainty relation. These conditions are proven to be necessary and sufficient for (1+N)-mode Gaussian states and for (M+N)-mode bisymmetric Gaussian states.

  8. Strategy development management of Multimodal Transport Network

    Directory of Open Access Journals (Sweden)

    Nesterova Natalia S.

    2016-01-01

    Full Text Available The article gives a brief overview of works on the development of transport infrastructure for multimodal transportation and integration of Russian transport system into the international transport corridors. The technology for control of the strategy, that changes shape and capacity of Multi-modal Transport Network (MTN, is considered as part of the methodology for designing and development of MTN. This technology allows to carry out strategic and operational management of the strategy implementation based on the use of the balanced scorecard.

  9. Translating board games: multimodality and play

    OpenAIRE

    Evans, Jonathan

    2013-01-01

    This article examines the translation of modern board games as multimodal texts. It argues that games are produced in the interaction between players, pieces and rules, making them a participatory form of text. The article analyses the elements of the rules and in-game text in order to show how the multimodal elements of the text are essential to the experience of the game and how they affect the translation process. Many games are designed to be translated for many markets and avoid unnecess...

  10. Multimodality hard-x-ray imaging of a chromosome with nanoscale spatial resolution

    Science.gov (United States)

    Yan, Hanfei; Nazaretski, Evgeny; Lauer, Kenneth; Huang, Xiaojing; Wagner, Ulrich; Rau, Christoph; Yusuf, Mohammed; Robinson, Ian; Kalbfleisch, Sebastian; Li, Li; Bouet, Nathalie; Zhou, Juan; Conley, Ray; Chu, Yong S.

    2016-02-01

    We developed a scanning hard x-ray microscope using a new class of x-ray nano-focusing optic called a multilayer Laue lens and imaged a chromosome with nanoscale spatial resolution. The combination of the hard x-ray’s superior penetration power, high sensitivity to elemental composition, high spatial-resolution and quantitative analysis creates a unique tool with capabilities that other microscopy techniques cannot provide. Using this microscope, we simultaneously obtained absorption-, phase-, and fluorescence-contrast images of Pt-stained human chromosome samples. The high spatial-resolution of the microscope and its multi-modality imaging capabilities enabled us to observe the internal ultra-structures of a thick chromosome without sectioning it.

  11. All-optically integrated multimodality imaging system: combined photoacoustic microscopy, optical coherence tomography, and fluorescence imaging

    Science.gov (United States)

    Chen, Zhongjiang; Yang, Sihua; Xing, Da

    2016-10-01

    We have developed a multimodality imaging system by optically integrating all-optical photoacoustic microscopy (AOPAM), optical coherence tomography (OCT) and fluorescence microscopy (FLM) to provide complementary information including optical absorption, optical back-scattering and fluorescence contrast of biological tissue. By sharing the same low-coherence Michelson interferometer, AOPAM and OCT could be organically optically combined to obtain the absorption and scattering information of the biological tissues. Also, owing to using the same laser source and objective lens, intrinsically registered photoacoustic and fluorescence signals are obtained to present the radiative and nonradiative transition process of absorption. Simultaneously photoacoustic angiography, tissue structure and fluorescence molecular in vivo images of mouse ear were acquired to demonstrate the capabilities of the optically integrated trimodality imaging system, which can present more information to study tumor angiogenesis, vasculature, anatomical structure and microenvironments in vivo.

  12. A portable confocal hyperspectral microscope without any scan or tube lens and its application in fluorescence and Raman spectral imaging

    Science.gov (United States)

    Li, Jingwei; Cai, Fuhong; Dong, Yongjiang; Zhu, Zhenfeng; Sun, Xianhe; Zhang, Hequn; He, Sailing

    2017-06-01

    In this study, a portable confocal hyperspectral microscope is developed. In traditional confocal laser scanning microscopes, scan lens and tube lens are utilized to achieve a conjugate relationship between the galvanometer and the back focal plane of the objective, in order to achieve a better resolution. However, these lenses make it difficult to scale down the volume of the system. In our portable confocal hyperspectral microscope (PCHM), the objective is placed directly next to the galvomirror. Thus, scan lens and tube lens are not included in our system and the size of this system is greatly reduced. Furthermore, the resolution is also acceptable in many biomedical and food-safety applications. Through reducing the optical length of the system, the signal detection efficiency is enhanced. This is conducive to realizing both the fluorescence and Raman hyperspectral imaging. With a multimode fiber as a pinhole, an improved image contrast is also achieved. Fluorescent spectral images for HeLa cells/fingers and Raman spectral images of kumquat pericarp are present. The spectral resolution and spatial resolutions are about 0.4 nm and 2.19 μm, respectively. These results demonstrate that this portable hyperspectral microscope can be used in in-vivo fluorescence imaging and in situ Raman spectral imaging.

  13. Connecting multimodality in human communication.

    Science.gov (United States)

    Regenbogen, Christina; Habel, Ute; Kellermann, Thilo

    2013-01-01

    DCM analysis instead showed a pronounced top-down control. Remarkably, all connections from the dmPFC to the three other regions were modulated by the experimental conditions. This observation is in line with the presumed role of the dmPFC in the allocation of attention. In contrary, all incoming connections to the AG were modulated, indicating its key role in integrating multimodal information and supporting comprehension. Notably, the input from the FFG to the AG was enhanced when facial expressions conveyed emotional information. These findings serve as preliminary results in understanding network dynamics in human emotional communication and empathy.

  14. Love that Book: Multimodal Response to Literature

    Science.gov (United States)

    Dalton, Bridget; Grisham, Dana L.

    2013-01-01

    Composing with different modes--image, sound, video and the written word--to respond to and analyze literary and informational text helps students develop as readers and digital communicators. This article showcases five multimodal strategies for engaging children in rich literature-based learning using digital tools and Internet resources.

  15. Design Options for Multimodal Web Applications

    Science.gov (United States)

    Stanciulescu, Adrian; Vanderdonckt, Jean

    The capabilities of multimodal applications running on the web are well de-lineated since they are mainly constrained by what their underlying standard mark up language offers, as opposed to hand-made multimodal applications. As the experience in developing such multimodal web applications is growing, the need arises to identify and define major design options of such application to pave the way to a structured development life cycle. This paper provides a design space of independent design options for multimodal web applications based on three types of modalities: graphical, vocal, tactile, and combined. On the one hand, these design options may provide designers with some explicit guidance on what to decide or not for their future user interface, while exploring various design alternatives. On the other hand, these design options have been implemented as graph transformations per-formed on a user interface model represented as a graph. Thanks to a transformation engine, it allows designers to play with the different values of each design option, to preview the results of the transformation, and to obtain the corresponding code on-demand

  16. Love that Book: Multimodal Response to Literature

    Science.gov (United States)

    Dalton, Bridget; Grisham, Dana L.

    2013-01-01

    Composing with different modes--image, sound, video and the written word--to respond to and analyze literary and informational text helps students develop as readers and digital communicators. This article showcases five multimodal strategies for engaging children in rich literature-based learning using digital tools and Internet resources.

  17. Multimodal representations in collaborative history learning

    NARCIS (Netherlands)

    Prangsma, M.E.

    2007-01-01

    This dissertation focuses on the question: How does making and connecting different types of multimodal representations affect the collaborative learning process and the acquisition of a chronological frame of reference in 12 to 14-year olds in pre vocational education? A chronological frame of refe

  18. A Multimodal Interaction Framework for Blended Learning

    DEFF Research Database (Denmark)

    Vidakis, Nikolaos; Kalafatis, Konstantinos; Triantafyllidis, Georgios

    2017-01-01

    Humans interact with each other by utilizing the five basic senses as input modalities, whereas sounds, gestures, facial expressions etc. are utilized as output modalities. Multimodal interaction is also used between humans and their surrounding environment, although enhanced with further senses ...... framework enabling deployment of a vast variety of modalities, tailored appropriately for use in blended learning environment....

  19. Controllable spatiotemporal nonlinear effects in multimode fibres

    Science.gov (United States)

    Wright, Logan G.; Christodoulides, Demetrios N.; Wise, Frank W.

    2015-05-01

    Multimode fibres are of interest for next-generation telecommunications systems and the construction of high-energy fibre lasers. However, relatively little work has explored nonlinear pulse propagation in multimode fibres. Here, we consider highly nonlinear ultrashort pulse propagation in the anomalous-dispersion regime of a graded-index multimode fibre. Low modal dispersion and strong nonlinear coupling between the fibre's many spatial modes result in interesting behaviour. We observe spatiotemporal effects reminiscent of nonlinear optics in bulk media—self-focusing and multiple filamentation—at a fraction of the usual power. By adjusting the spatial initial conditions, we generate on-demand, megawatt, ultrashort pulses tunable between 1,550 and 2,200 nm dispersive waves over one octave; intense combs of visible light; and a multi-octave-spanning supercontinuum. Our results indicate that multimode fibres present unique opportunities for observing new spatiotemporal dynamics and phenomena. They also enable the realization of a new type of tunable, broadband fibre source that could be useful for many applications.

  20. Multimode waveguide speckle patterns for compressive sensing.

    Science.gov (United States)

    Valley, George C; Sefler, George A; Justin Shaw, T

    2016-06-01

    Compressive sensing (CS) of sparse gigahertz-band RF signals using microwave photonics may achieve better performances with smaller size, weight, and power than electronic CS or conventional Nyquist rate sampling. The critical element in a CS system is the device that produces the CS measurement matrix (MM). We show that passive speckle patterns in multimode waveguides potentially provide excellent MMs for CS. We measure and calculate the MM for a multimode fiber and perform simulations using this MM in a CS system. We show that the speckle MM exhibits the sharp phase transition and coherence properties needed for CS and that these properties are similar to those of a sub-Gaussian MM with the same mean and standard deviation. We calculate the MM for a multimode planar waveguide and find dimensions of the planar guide that give a speckle MM with a performance similar to that of the multimode fiber. The CS simulations show that all measured and calculated speckle MMs exhibit a robust performance with equal amplitude signals that are sparse in time, in frequency, and in wavelets (Haar wavelet transform). The planar waveguide results indicate a path to a microwave photonic integrated circuit for measuring sparse gigahertz-band RF signals using CS.

  1. The Arts, New Literacies, and Multimodality

    Science.gov (United States)

    Albers, Peggy; Harste, Jerome C.

    2007-01-01

    The arts, multimodality, and new literacies studies, each with its own distinct principles, together can redefine literacy and what constitutes being literate. To recognize the roles that each of these fields plays in literacy necessitates a cultural shift in reading, interpreting, creating, and responding to a range of multimedia messages. The…

  2. Multimode interferometer for guided matter waves.

    Science.gov (United States)

    Andersson, Erika; Calarco, Tommaso; Folman, Ron; Andersson, Mauritz; Hessmo, Björn; Schmiedmayer, Jörg

    2002-03-11

    Atoms can be trapped and guided with electromagnetic fields, using nanofabricated structures. We describe the fundamental features of an interferometer for guided matter waves, built of two combined Y-shaped beam splitters. We find that such a device is expected to exhibit high contrast fringes even in a multimode regime, analogous to a white light interferometer.

  3. Brain-Computer Interaction: Can Multimodality Help?

    NARCIS (Netherlands)

    Nijholt, Antinus; Allison, Brendan Z.; Jacobs, Robert J.K.; Vidal, E.; Gatica-Perez, D.; Morency, L.P.; Sebe, N.

    2011-01-01

    This paper is a short introduction to a special ICMI session on brain-computer interaction. During this paper, we first discuss problems, solutions, and a five-year view for brain-computer interaction. We then talk further about unique issues with multimodal and hybrid brain-computer interfaces,

  4. Single versus multimodality training basic laparoscopic skills

    NARCIS (Netherlands)

    Brinkman, W.M.; Havermans, S.Y.; Buzink, S.N.; Botden, S.M.B.I.; Jakimowicz, J.J.; Schoot, B.C.

    2012-01-01

    Introduction - Even though literature provides compelling evidence of the value of simulators for training of basic laparoscopic skills, the best way to incorporate them into a surgical curriculum is unclear. This study compares the training outcome of single modality training with multimodality tra

  5. Academic Knowledge Construction and Multimodal Curriculum Development

    Science.gov (United States)

    Loveless, Douglas J., Ed.; Griffith, Bryant, Ed.; Bérci, Margaret E., Ed.; Ortlieb, Evan, Ed.; Sullivan, Pamela, Ed.

    2014-01-01

    While incorporating digital technologies into the classroom has offered new ways of teaching and learning into educational processes, it is essential to take a look at how the digital shift impacts teachers, school administration, and curriculum development. "Academic Knowledge Construction and Multimodal Curriculum Development" presents…

  6. Multimodal Dialogue Management - State of the art

    NARCIS (Netherlands)

    Bui Huu Trung, B.H.T.

    This report is about the state of the art in dialogue management. We first introduce an overview of a multimodal dialogue system and its components. Second, four main approaches to dialogue management are described (finite-state and frame-based, information-state based and probabilistic, plan-based,

  7. Reconceptualising Poetry as a Multimodal Genre

    Science.gov (United States)

    Newfield, Denise; D'abdon, Raphael

    2015-01-01

    This conceptual article theorises the role of poetry in English classrooms from a multimodal perspective. It discusses the gap between the practices of poetry inside and outside South African schools, particularly where English is taught as an additional language (EAL). The former is shown to be monomodal and prescriptive, while the latter is…

  8. Multimodal Interaction with a Virtual Guide

    NARCIS (Netherlands)

    Hofs, D.H.W.; Theune, Mariet; op den Akker, Hendrikus J.A.

    2008-01-01

    We demonstrate the Virtual Guide, an embodied conversational agent that gives directions in a 3D environment. We briefly describe multimodal dialogue management, language and gesture generation, and a special feature of the Virtual Guide: the ability to align her linguistic style to the user’s level

  9. Visible Quotation : The multimodal expression of viewpoint

    NARCIS (Netherlands)

    Stec, Kashmiri Kristina Mukti

    2016-01-01

    The central theme of this dissertation is multimodal viewpoint – that is, the way that bodily actions work together with spoken language to express the perspective of characters within a narrative. Drawing on research in cognitive linguistics, conversation analysis, gesture studies, and signed langu

  10. Multimodal representations in collaborative history learning

    NARCIS (Netherlands)

    Prangsma, M.E.

    2007-01-01

    This dissertation focuses on the question: How does making and connecting different types of multimodal representations affect the collaborative learning process and the acquisition of a chronological frame of reference in 12 to 14-year olds in pre vocational education? A chronological frame of refe

  11. Single versus multimodality training basic laparoscopic skills

    NARCIS (Netherlands)

    Brinkman, W.M.; Havermans, S.Y.; Buzink, S.N.; Botden, S.M.B.I.; Jakimowicz, J.J.; Schoot, B.C.

    2012-01-01

    Introduction - Even though literature provides compelling evidence of the value of simulators for training of basic laparoscopic skills, the best way to incorporate them into a surgical curriculum is unclear. This study compares the training outcome of single modality training with multimodality

  12. Academic Knowledge Construction and Multimodal Curriculum Development

    Science.gov (United States)

    Loveless, Douglas J., Ed.; Griffith, Bryant, Ed.; Bérci, Margaret E., Ed.; Ortlieb, Evan, Ed.; Sullivan, Pamela, Ed.

    2014-01-01

    While incorporating digital technologies into the classroom has offered new ways of teaching and learning into educational processes, it is essential to take a look at how the digital shift impacts teachers, school administration, and curriculum development. "Academic Knowledge Construction and Multimodal Curriculum Development" presents…

  13. Equilibrium models in multimodal container transport systems

    NARCIS (Netherlands)

    Corman, F.; Viti, F.; Negenborn, R.R.

    2015-01-01

    Optimizing the performance of multimodal freight transport networks involves adequately balancing the interplay between costs, volumes, times of departure and arrival, and times of travel. In order to study this interplay, we propose an assignment model that is able to efficiently determine flows an

  14. Multimodal representations in collaborative history learning

    NARCIS (Netherlands)

    Prangsma, M.E.

    2007-01-01

    This dissertation focuses on the question: How does making and connecting different types of multimodal representations affect the collaborative learning process and the acquisition of a chronological frame of reference in 12 to 14-year olds in pre vocational education? A chronological frame of

  15. Interactive Multimodal Learning for Venue Recommendation

    NARCIS (Netherlands)

    Zahálka, J.; Rudinac, S.; Worring, M.

    2015-01-01

    In this paper, we propose City Melange, an interactive and multimodal content-based venue explorer. Our framework matches the interacting user to the users of social media platforms exhibiting similar taste. The data collection integrates location-based social networks such as Foursquare with genera

  16. Affective multimodal mirror: sensing and eliciting laughter

    NARCIS (Netherlands)

    Melder, W.A.; Truong, K.P.; Uyl, M. den; Leeuwen, D.A. van; Neerincx, M.A.; Loos, L.R.; Stock Plum, B.

    2007-01-01

    In this paper, we present a multimodal affective mirror that senses and elicits laughter. Currently, the mirror contains a vocal and a facial affect-sensing module, a component that fuses the output of these two modules to achieve a user-state assessment, a user state transition model, and a compone

  17. Conjugate metamaterials and the perfect lens

    CERN Document Server

    Xu, Yadong; Xu, Lin; Chen, Huanyang

    2015-01-01

    In this letter, we show how transformation optics makes it possible to design what we call conjugate metamaterials. We show that these materials can also serve as substrates for making a subwavelength-resolution lens. The so-called "perfect lens", which is a lens that could focus all components of light (including propagating and evanescent waves), can be regarded as a limiting case, in which the respective conjugate metamaterials approach the characteristics of left-handed metamaterials, which have a negative refractive index.

  18. PMMA lens with high efficiency and reliability

    Science.gov (United States)

    Matsuzaki, Ichiro; Abe, Koji; Fujita, Katsuhiro

    2013-09-01

    Polymethyl Methacrylate (PMMA) Fresnel lenses are increasingly being used in concentrated photovoltaic (CPV) systems installed outdoors and, accordingly, emphasis is being placed on the durability of such lenses with regard to light transmittance when subject to ultraviolet (UV) light and dust exposure. Accelerated testing methods for evaluating durability under UV exposure were established, allowing development of a lens material with improved UV resistance. Simultaneously, through a proprietary molding method, a Fresnel lens that boasts favorable light concentration efficiency with little deformation even after prolonged outdoor use was developed. Moreover, the lens incorporates a new hard-coat finish that possesses sand durability and UV resistance comparable to that of tempered glass.

  19. Bionic intraocular lens with variable focus and integrated structure

    Science.gov (United States)

    Liang, Dan; Wang, Xuan-Yin; Du, Jia-Wei; Xiang, Ke

    2015-10-01

    This paper proposes a bionic accommodating intraocular lens (IOL) for ophthalmic surgery. The designed lens has a solid-liquid mixed integrated structure, which mainly consists of a support ring, elastic membrane, rigid lens, and optical liquid. The lens focus can be adjusted through the deformation of the lens front surface when compressed. The integrated structure of the IOL is presented, as well as a detailed description of the lens materials and fabrication process. Images under different radial pressures are captured, and the lens deformation process, accommodating range, density, and optical property are analyzed. The designed lens achieves a 14.6 D accommodating range under a radial pressure of 51.4 mN and a 0.24 mm alteration of the lens outer radius. The deformation property of the lens matches well with the characteristic of the eye and shows the potential to help patients fully recover their vision accommodation ability after the cataract surgery.

  20. Restoring lens capsule integrity enhances lens regeneration in New Zealand albino rabbits and cats.

    Science.gov (United States)

    Gwon, A; Gruber, L J; Mantras, C

    1993-11-01

    In studies conducted by numerous investigators for 150 years, lenses regenerated following endocapsular lens extraction in New Zealand albino rabbits have been irregular in shape, appearing primarily doughnut-shaped as a result of lack of lens growth at the site of the anterior capsulotomy and its adhesion to the posterior capsule. In the present study, we restored the lens capsule integrity by inserting a collagen patch at the time of surgery to seal the anterior capsulotomy and to improve the shape and structure of the regenerated lenses. We then filled the capsule bag with air to prevent adhesions between the anterior and posterior capsule and maintain capsule tautness and shape. Lens regeneration was first noted as early as one to two weeks. Regenerated lens filled approximately 50% of the capsule bag at two weeks and 100% by five weeks. Subsequent growth was in the anterior-posterior direction and measured by A-scan biometry. Lens thickness increased by 0.3 mm per month. The regenerated lenses were spherical with normal cortical structure and a nuclear opacity. In conclusion, restoration of lens capsular integrity with a collagen patch following endocapsular lens extraction enhanced the shape, structure, and growth rate of the regenerated lenses. In addition, lens regeneration was shown to occur in two cats.

  1. Conjunctival Microbiome Changes Associated With Soft Contact Lens and Orthokeratology Lens Wearing.

    Science.gov (United States)

    Zhang, Haikun; Zhao, Fuxin; Hutchinson, Diane S; Sun, Wenfeng; Ajami, Nadim J; Lai, Shujuan; Wong, Matthew C; Petrosino, Joseph F; Fang, Jianhuo; Jiang, Jun; Chen, Wei; Reinach, Peter S; Qu, Jia; Zeng, Changqing; Zhang, Dake; Zhou, Xiangtian

    2017-01-01

    Usage of different types of contact lenses is associated with increased risk of sight-threatening complications. Changes in the ocular microbiome caused by contact lens wear are suggested to affect infection development in those individuals. To address this question, this study compares conjunctival microbial communities in contact lens wearers with those in noncontact lens wearers. Paired-end sequencing of the V3 region of the 16S rRNA gene was used to characterize the bacterial communities on the conjunctival surfaces of contact lens wearers and nonwearers. No differences in microbial diversity were detected between contact lens wearers and nonwearers. Nevertheless, some slight microbe variability was evident between these two different groups. Bacillus, Tatumella and Lactobacillus abundance was less in orthokeratology lens (OKL) wearers than in nonwearers. In soft contact lenses (SCL) wearers, Delftia abundance decreased whereas Elizabethkingia levels increased. The difference in the SCL and nonwearer group was smaller than that in the OKL group. Variations in the conjunctival taxonomic composition between SCL wearers were larger than those in other groups. Sex differences in the conjunctival microbiota makeup were only evident among nonwearers. Even though there were slight percentage changes between contact lens wearers and nonwearers in some microbes, there were no differences in their diversity. On the other hand, contact lens usage might cause relative abundance of some taxa to change. Our results will help assess whether or not conjunctival microbiome changes caused by contact lens wear affect infection risk.

  2. Variable-focus cylindrical liquid lens array

    Science.gov (United States)

    Zhao, Wu-xiang; Liang, Dong; Zhang, Jie; Liu, Chao; Zang, Shang-fei; Wang, Qiong-hua

    2013-06-01

    A variable-focus cylindrical liquid lens array based on two transparent liquids of different refractive index is demonstrated. An elastic membrane divides a transparent reservoir into two chambers. The two chambers are filled with liquid 1 and liquid 2, respectively, which are of different refractive index. The micro-clapboards help liquid 1, liquid 2 and the elastic membrane form a cylindrical lens array. Driving these two liquids to flow can change the shape of the elastic membrane as well as the focal length. In this design, the gravity effect of liquid can be overcome. A demo lens array of positive optical power is developed and tested. Moreover, a potential application of the proposed lens array for autostereoscopic 3D displays is emphasized.

  3. Role of Aquaporin 0 in lens biomechanics

    Energy Technology Data Exchange (ETDEWEB)

    Sindhu Kumari, S.; Gupta, Neha [Physiology and Biophysics, Stony Brook University, Stony Brook, NY (United States); Shiels, Alan [Washington University School of Medicine, St. Louis, MO (United States); FitzGerald, Paul G. [Cell Biology and Human Anatomy, School of Medicine, University of California, Davis, CA (United States); Menon, Anil G. [University of Cincinnati College of Medicine, Cincinnati, OH (United States); Mathias, Richard T. [Physiology and Biophysics, Stony Brook University, Stony Brook, NY (United States); SUNY Eye Institute, NY (United States); Varadaraj, Kulandaiappan, E-mail: kulandaiappan.varadaraj@stonybrook.edu [Physiology and Biophysics, Stony Brook University, Stony Brook, NY (United States); SUNY Eye Institute, NY (United States)

    2015-07-10

    Maintenance of proper biomechanics of the eye lens is important for its structural integrity and for the process of accommodation to focus near and far objects. Several studies have shown that specialized cytoskeletal systems such as the beaded filament (BF) and spectrin-actin networks contribute to mammalian lens biomechanics; mutations or deletion in these proteins alters lens biomechanics. Aquaporin 0 (AQP0), which constitutes ∼45% of the total membrane proteins of lens fiber cells, has been shown to function as a water channel and a structural cell-to-cell adhesion (CTCA) protein. Our recent ex vivo study on AQP0 knockout (AQP0 KO) mouse lenses showed the CTCA function of AQP0 could be crucial for establishing the refractive index gradient. However, biomechanical studies on the role of AQP0 are lacking. The present investigation used wild type (WT), AQP5 KO (AQP5{sup −/−}), AQP0 KO (heterozygous KO: AQP0{sup +/−}; homozygous KO: AQP0{sup −/−}; all in C57BL/6J) and WT-FVB/N mouse lenses to learn more about the role of fiber cell AQPs in lens biomechanics. Electron microscopic images exhibited decreases in lens fiber cell compaction and increases in extracellular space due to deletion of even one allele of AQP0. Biomechanical assay revealed that loss of one or both alleles of AQP0 caused a significant reduction in the compressive load-bearing capacity of the lenses compared to WT lenses. Conversely, loss of AQP5 did not alter the lens load-bearing ability. Compressive load-bearing at the suture area of AQP0{sup +/−} lenses showed easy separation while WT lens suture remained intact. These data from KO mouse lenses in conjunction with previous studies on lens-specific BF proteins (CP49 and filensin) suggest that AQP0 and BF proteins could act co-operatively in establishing normal lens biomechanics. We hypothesize that AQP0, with its prolific expression at the fiber cell membrane, could provide anchorage for cytoskeletal structures like BFs and

  4. Ensuring Safe Use of Contact Lens Solution

    Science.gov (United States)

    ... evaluating contact lens solutions and the development of Acanthamoeba keratitis, a rare but serious eye infection that's ... contact lenses to water has been associated with Acanthamoeba keratitis, a corneal infection that is resistant to ...

  5. Role of Aquaporin 0 in lens biomechanics.

    Science.gov (United States)

    Sindhu Kumari, S; Gupta, Neha; Shiels, Alan; FitzGerald, Paul G; Menon, Anil G; Mathias, Richard T; Varadaraj, Kulandaiappan

    2015-07-10

    Maintenance of proper biomechanics of the eye lens is important for its structural integrity and for the process of accommodation to focus near and far objects. Several studies have shown that specialized cytoskeletal systems such as the beaded filament (BF) and spectrin-actin networks contribute to mammalian lens biomechanics; mutations or deletion in these proteins alters lens biomechanics. Aquaporin 0 (AQP0), which constitutes ∼45% of the total membrane proteins of lens fiber cells, has been shown to function as a water channel and a structural cell-to-cell adhesion (CTCA) protein. Our recent ex vivo study on AQP0 knockout (AQP0 KO) mouse lenses showed the CTCA function of AQP0 could be crucial for establishing the refractive index gradient. However, biomechanical studies on the role of AQP0 are lacking. The present investigation used wild type (WT), AQP5 KO (AQP5(-/-)), AQP0 KO (heterozygous KO: AQP0(+/-); homozygous KO: AQP0(-/-); all in C57BL/6J) and WT-FVB/N mouse lenses to learn more about the role of fiber cell AQPs in lens biomechanics. Electron microscopic images exhibited decreases in lens fiber cell compaction and increases in extracellular space due to deletion of even one allele of AQP0. Biomechanical assay revealed that loss of one or both alleles of AQP0 caused a significant reduction in the compressive load-bearing capacity of the lenses compared to WT lenses. Conversely, loss of AQP5 did not alter the lens load-bearing ability. Compressive load-bearing at the suture area of AQP0(+/-) lenses showed easy separation while WT lens suture remained intact. These data from KO mouse lenses in conjunction with previous studies on lens-specific BF proteins (CP49 and filensin) suggest that AQP0 and BF proteins could act co-operatively in establishing normal lens biomechanics. We hypothesize that AQP0, with its prolific expression at the fiber cell membrane, could provide anchorage for cytoskeletal structures like BFs and together they help to confer

  6. Veselago lens by photonic hyper-crystals

    CERN Document Server

    Huang, Zun

    2014-01-01

    An imaging system functioning as a Veselago lens has been proposed based on the novel concept of photonic "hyper-crystal" -- an artificial optical medium synthesizing the properties of hyperbolic materials and photonic crystals. This Veselago lens shows a nearly constant negative refractive index and substantially reduced image aberrations. It can find potential applications in photolithography and hot-spots detection of silicon-based integrated circuits.

  7. Lens Design Using Group Indices of Refraction

    Science.gov (United States)

    Vaughan, A. H.

    1995-01-01

    An approach to lens design is described in which the ratio of the group velocity to the speed of light (the group index) in glass is used, in conjunction with the more familiar phase index of refraction, to control certain chromatic properties of a system of thin lenses in contact. The first-order design of thin-lens systems is illustrated by examples incorporating the methods described.

  8. In vivo human crystalline lens topography

    OpenAIRE

    Ortiz, Sergio; Pérez Merino, Pablo; Gambra, Enrique; Castro, Alberto; Marcos, Susana

    2012-01-01

    Custom high-resolution high-speed anterior segment spectral domain optical coherence tomography (OCT) was used to characterize three-dimensionally (3-D) the human crystalline lens in vivo. The system was provided with custom algorithms for denoising and segmentation of the images, as well as for fan (scanning) and optical (refraction) distortion correction, to provide fully quantitative images of the anterior and posterior crystalline lens surfaces. The method was tested on an artificial eye ...

  9. Environmental standards for intraocular lens implantation.

    Science.gov (United States)

    Crawford, B A; Kaufman, D V

    1984-02-01

    Successful implantation of prosthetic devices depends upon their freedom from postoperative inflammation and infection. Techniques and lessons learned in orthopaedic and other implant surgery should be applied to intraocular lens implantation. The avoidance of contamination by particles and micro-organisms is one essential principle of the surgical procedure. Practical steps are described to reduce both types of contamination. These measures taken together are recommended for adoption as a standard of environmental safety for lens implantation.

  10. A Spectrometer Based on Diffractive Lens

    Institute of Scientific and Technical Information of China (English)

    WANG Daoyi; YAN Yingbai; JIN Guofan; WU Minxian

    2001-01-01

    A novel spectrometer is designed based on diffractive lens. It is essentially a flat field spectrometer. All the focal points are along the optical axis. Besides, all the asymmetrical aberrations vanish in our mounting. Thus low aberration can be obtained. In this article a diffractive lens is modeled as a special grating and analyzed by using a grating-based method. And a stigmatic point is introduced to reduce the aberrations.

  11. Bilateral Pseudoexfoliation Deposits on Intraocular Lens Implants

    OpenAIRE

    Elena Bonafonte Marquez; Sergio Bonafonte Royo

    2015-01-01

    We present a rare case of bilateral pseudoexfoliative deposits on both intraocular lens (IOL) implants in an 83-year-old woman with no other associated pathology, 5 years after cataract surgery. Pseudoexfoliation syndrome is the most common cause of secondary open-angle glaucoma worldwide and these deposits are usually found on the natural lens. The fact that pseudoexfoliative deposits have been found on IOL implants implies the need for a thorough examination in pseudophakic patients, for i...

  12. Introduction to the development of intraocular lens

    Science.gov (United States)

    Li, Yifan; Peng, Runling; Hu, Shuilan; Wei, Maowei; Chen, Jiabi

    2013-08-01

    In order to cure the cataract disease or injuries in eyes, intraocular lens(IOL) has been studied all the time to replace the crystalline lens in human eyes. Researches on IOL are started early from 19th century, and it develops greatly in the hundreds years after. This article introduces several main kinds of IOLs that appear in the development history of IOL, and raises the double-liquid zoom IOL based on electrowetting, which will be the trend of IOL study.

  13. Evolution and the Calcite Eye Lens

    CERN Document Server

    Williams, Vernon L

    2013-01-01

    Calcite is a uniaxial, birefringent crystal, which in its optically transparent form, has been used for animal eye lenses, the trilobite being one such animal. Because of the calcite birefringence there is a difficulty in using calcite as a lens. When the propagation direction of incoming light is not exactly on the c-axis, the mages blur. In this paper, calcite blurring is evaluated, and the non-blurring by a crystallin eye lens is compared to a calcite one.

  14. A correlation of thin lens approximation to thick lens design by using context based method in optics education

    Science.gov (United States)

    Farsakoglu, O. F.; Inal Atik, Ipek; Kocabas, Hikmet

    2014-07-01

    The effect of Coddington factors on aberration functions has been analysed using thin lens approximation with optical glass parameters. The dependence of spherical aberration on Coddington shape factor for the various optical glasses in real lens design was discussed using exact ray tracing for the optics education and training purposes. Thin lens approximation and thick lens design are generally taught with only lecturing method. But, thick lens design is closely related to the real life. Hence, it is more appropriate to teach thin lens approximation and thick lens design with real-life context based approach. Context based teaching can be effective in solving problems in which the subject is very difficult and irrelevant. It also provides extensive evidence for optics education that students are generally unable to correctly apply the concepts of lens design to optical instruments currently used. Therefore, the outline of real-life context based thick lens design lessons were proposed and explained in detail considering thin lens approximation.

  15. Photon nanojet lens: design, fabrication and characterization

    Science.gov (United States)

    Xu, Chen; Zhang, Sichao; Shao, Jinhai; Lu, Bing-Rui; Mehfuz, Reyad; Drakeley, Stacey; Huang, Fumin; Chen, Yifang

    2016-04-01

    In this paper, a novel nanolens with super resolution, based on the photon nanojet effect through dielectric nanostructures in visible wavelengths, is proposed. The nanolens is made from plastic SU-8, consisting of parallel semi-cylinders in an array. This paper focuses on the lens designed by numerical simulation with the finite-difference time domain method and nanofabrication of the lens by grayscale electron beam lithography combined with a casting/bonding/lift-off transfer process. Monte Carlo simulation for injected charge distribution and development modeling was applied to define the resultant 3D profile in PMMA as the template for the lens shape. After the casting/bonding/lift-off process, the fabricated nanolens in SU-8 has the desired lens shape, very close to that of PMMA, indicating that the pattern transfer process developed in this work can be reliably applied not only for the fabrication of the lens but also for other 3D nanopatterns in general. The light distribution through the lens near its surface was initially characterized by a scanning near-field optical microscope, showing a well defined focusing image of designed grating lines. Such focusing function supports the great prospects of developing a novel nanolithography based on the photon nanojet effect.

  16. Lens Biology is a Dimension of Neurobiology.

    Science.gov (United States)

    Frederikse, Peter; Kasinathan, Chinnaswamy

    2017-02-04

    There is a second cell type in your body that expresses scores of the most intensively studied genes in neuroscience and exclusively shares critical interdependent modes of molecular regulation that include a network first described as responsible for the basic bifurcation of neuronal from non-neuronal gene expression in vertebrates. Neurons and lens cells are among the most ancient animal cell types, yet neurons have an exclusive status also attributed to roles underlying sensation, movement, and cognition. However, this status is challenged by cells in the lens of the eye. The extent and detail of internally consistent parallels with neuron biology now catalogued in their second native cell type in the lens provide a detailed model of interdependent neuron gene expression in lens development and non-neuronal role in vision. These comprehensive parallels identify the lens as a dimension of neurobiology and a fundamental new perspective on neurodevelopment and its disorders. Finally, this understanding identifies that hallmark neuronal gene expression and key modes of associated molecular regulation evolved in tandem in the lens.

  17. Conservation through the economics lens.

    Science.gov (United States)

    Farley, Joshua

    2010-01-01

    Although conservation is an inherently transdisciplinary issue, there is much to be gained from examining the problem through an economics lens. Three benefits of such an approach are laid out in this paper. First, many of the drivers of environmental degradation are economic in origin, and the better we understand them, the better we can conserve ecosystems by reducing degradation. Second, economics offers us a when-to-stop rule, which is equivalent to a when-to-conserve rule. All economic production is based on the transformation of raw materials provided by nature. As the economic system grows in physical size, it necessarily displaces and degrades ecosystems. The marginal benefits of economic growth are diminishing, and the marginal costs of ecological degradation are increasing. Conceptually, we should stop economic growth and focus on conservation when the two are equal. Third, economics can help us understand how to efficiently and justly allocate resources toward conservation, and this paper lays out some basic principles for doing so. Unfortunately, the field of economics is dominated by neoclassical economics, which builds an analytical framework based on questionable assumptions and takes an excessively disciplinary and formalistic approach. Conservation is a complex problem, and analysis from individual disciplinary lenses can make important contributions to conservation only when the resulting insights are synthesized into a coherent vision of the whole. Fortunately, there are a number of emerging transdisciplines, such as ecological economics and environmental management, that are dedicated to this task.

  18. Digital Landscapes: Rethinking Poetry Interpretation in Multimodal Texts

    Directory of Open Access Journals (Sweden)

    Hessa A. Alghadeer

    2014-03-01

    Full Text Available Regardless of the fact that a great deal of scholarly studies in the field of digital humanities have emphasized implementing various modes of digital literacy, critical perspectives considering the use of multimodal texts in literature, namely poetry, have received scant attention. Beyond the boundaries of printed texts and verbal means, the present study aims to cast some light on how meaning making in poetry into multimodal contexts becomes crucial to poetry interpretation in multimodal contexts. In particular, the study tackles the theory of multimodality in regard to the poetry genre and briefly reviews its significance in relevant studies. The paper then shifts to show how the multimodalities in question enhance the transformation of print-based poetic texts into creative multimodal poetry experiences. Ultimately, the study provides insight into how digital media have altered our perspectives on definitions, interpretations, and appreciation of poetry.

  19. An Adaptive Multimodal Biometrics System using PSO

    Directory of Open Access Journals (Sweden)

    Ola M. Aly

    2013-08-01

    Full Text Available Multimodal biometric systems which fuse information from a number of biometrics, are gaining more attentions lately because they are able to overcome limitations in unimodal biometric systems. These systems are suited for high security applications. Most of the proposed multibiometric systems offer one level of security. In this paper a new approach for adaptive combination of multiple biometrics has been proposed to ensure multiple levels of security. The score level fusion rule is adapted using (PSO Particle Swarm Optimization to ensure the desired system performance corresponding to the desired level of security. The experimental results prove that the proposed multimodal biometric system is appropriate for applications that require different levels of security.

  20. A Multimodal Nanocomposite for Biomedical Imaging

    Science.gov (United States)

    Wu, Aiguo; Paunesku, Tatjana; Zhang, Zhuoli; Vogt, Stefan; Lai, Barry; Maser, Jörg; Yaghmai, Vahid; Li, Debiao; Omary, Reed A.; Woloschak, Gayle E.

    2013-01-01

    A multimodal nanocomposite was designed, synthesized with super-paramagnetic core (CoFe2O4), noble metal corona (Au), and semiconductor shell (TiO2). The sizes of core, core-corona, and core-corona-shell particles were determined by TEM. This multimodal nanocrystal showed promise as a contrast agent for two of the most widely used biomedical imaging techniques: magnetic resonance imaging (MRI) and X-ray computed tomography (CT). Finally, these nanocomposites were coated with a peptide SN-50. This led to their ready uptake by the cultured cells and targeted the nanocomposites to the pores of nuclear membrane. Inside cells, this nanocomposite retained its integrity as shown by X-ray fluorescence microscopy (XFM). Inside cells imaged by XFM we found the complex elemental signature of nanoconjugates (Ti-Co-Fe-Au) always co-registered in the 2D elemental map of the cell. PMID:24817775

  1. Comparing Paper and Tangible, Multimodal Tools

    Energy Technology Data Exchange (ETDEWEB)

    McGee, David R.(BATTELLE (PACIFIC NW LAB)); Cohen, Philip R.(Oregon Graduate Institute); Wesson, R M.(Oregon Graduate Institute); Horman, Sheilah (Oregon Graduate Institute)

    2002-01-01

    Officers in command posts maintain situational awareness using paper maps, Post-it notes, and hand-written annotations. They do so because paper is robust to failure, it is portable and malleable, it offers ultra-high resolution and supports face-to-face collaboration. We report herein on an evaluation comparing maps and Post-its with a tangible multimodal system called Rasa that augments the paper tools with sensors, enabling it to recognize the multimodal language (both written and spoken) that naturally occurs there. In this study, we found that not only do users prefer Rasa to paper alone, they find it as easy or easier to use than paper tools. Moreover, Rasa introduces no discernible overhead in its operation other than error repair, yet grants the benefits inherent in digital systems. Finally, subjects confirmed that by combining physical and computational tools, Rasa is resistant to computational failure.

  2. Multimodal interaction in image and video applications

    CERN Document Server

    Sappa, Angel D

    2013-01-01

    Traditional Pattern Recognition (PR) and Computer Vision (CV) technologies have mainly focused on full automation, even though full automation often proves elusive or unnatural in many applications, where the technology is expected to assist rather than replace the human agents. However, not all the problems can be automatically solved being the human interaction the only way to tackle those applications. Recently, multimodal human interaction has become an important field of increasing interest in the research community. Advanced man-machine interfaces with high cognitive capabilities are a hot research topic that aims at solving challenging problems in image and video applications. Actually, the idea of computer interactive systems was already proposed on the early stages of computer science. Nowadays, the ubiquity of image sensors together with the ever-increasing computing performance has open new and challenging opportunities for research in multimodal human interaction. This book aims to show how existi...

  3. Towards multimodal nonlinear optical tomography - experimental methodology

    Science.gov (United States)

    Vogler, N.; Medyukhina, A.; Latka, I.; Kemper, S.; Böhm, M.; Dietzek, B.; Popp, J.

    2011-08-01

    All-optical microspectroscopic and tomographic tools reveal great potential for clinical dermatologic diagnostics, i.e., investigation of human skin and skin diseases. While optical-coherence tomography has been complemented by two-photon fluorescence tomography and second-harmonic generation tomography, a joint study of various nonlinear optical microspectroscopies, i.e., application of the recently developed multimodal imaging approach, to sizable human-tissue samples has not been evaluated up to now. Here, we present such multimodal approach combining different nonlinear optical contrast mechanisms for imaging, namely two-photon excited fluorescence (TPF), second-harmonic generation (SHG), and coherent anti-Stokes Raman scattering (CARS) into a joint microscopic experiment. We show the potential of imaging large skin areas and discuss the information obtained in a case study comparing normal skin and keloid tissue.

  4. Fock expansion of multimode pure Gaussian states

    Energy Technology Data Exchange (ETDEWEB)

    Cariolaro, Gianfranco; Pierobon, Gianfranco, E-mail: gianfranco.pierobon@unipd.it [Università di Padova, Padova (Italy)

    2015-12-15

    The Fock expansion of multimode pure Gaussian states is derived starting from their representation as displaced and squeezed multimode vacuum states. The approach is new and appears to be simpler and more general than previous ones starting from the phase-space representation given by the characteristic or Wigner function. Fock expansion is performed in terms of easily evaluable two-variable Hermite–Kampé de Fériet polynomials. A relatively simple and compact expression for the joint statistical distribution of the photon numbers in the different modes is obtained. In particular, this result enables one to give a simple characterization of separable and entangled states, as shown for two-mode and three-mode Gaussian states.

  5. Multimodality imaging in nanomedicine and nanotheranostics

    Institute of Scientific and Technical Information of China (English)

    Xue Li; Xue-Ning Zhang; Xiao-Dong Li; Jin Chang

    2016-01-01

    Accurate diagnosis of tumors needs much detailed information. However, available single imaging modality cannot provide complete or comprehensive data. Nanomedicine is the application of nanotechnology to medicine, and multimodality imaging based on nanoparticles has been receiving extensive attention. This new hybrid imaging technology could provide complementary information from different imaging modalities using only a single injection of contrast agent. In this review, we introduce recent developments in multifunctional nanoparticles and their biomedical applications to multimodal imaging and theragnosis as nanomedicine. Most of the reviewed studies are based on the intrinsic properties of nanoparticles and their application in clinical imaging technology. The imaging techniques include positron emission tomography, single-photon emission computed tomography, computerized tomography, magnetic resonance imaging, optical imaging, and ultrasound imaging.

  6. Multimodality imaging of the postoperative shoulder

    Energy Technology Data Exchange (ETDEWEB)

    Woertler, Klaus [Technische Universitaet Muenchen, Department of Radiology, Munich (Germany)

    2007-12-15

    Multimodality imaging of the postoperative shoulder includes radiography, magnetic resonance (MR) imaging, MR arthrography, computed tomography (CT), CT arthrography, and ultrasound. Target-oriented evaluation of the postoperative shoulder necessitates familiarity with surgical techniques, their typical complications and sources of failure, knowledge of normal and abnormal postoperative findings, awareness of the advantages and weaknesses with the different radiologic techniques, and clinical information on current symptoms and function. This article reviews the most commonly used surgical procedures for treatment of anterior glenohumeral instability, lesions of the labral-bicipital complex, subacromial impingement, and rotator cuff lesions and highlights the significance of imaging findings with a view to detection of recurrent lesions and postoperative complications in a multimodality approach. (orig.)

  7. Multimodal location estimation of videos and images

    CERN Document Server

    Friedland, Gerald

    2015-01-01

    This book presents an overview of the field of multimodal location estimation, i.e. using acoustic, visual, and/or textual cues to estimate the shown location of a video recording. The authors' sample research results in this field in a unified way integrating research work on this topic that focuses on different modalities, viewpoints, and applications. The book describes fundamental methods of acoustic, visual, textual, social graph, and metadata processing as well as multimodal integration methods used for location estimation. In addition, the text covers benchmark metrics and explores the limits of the technology based on a human baseline. ·         Discusses localization of multimedia data; ·         Examines fundamental methods of establishing location metadata for images and videos (other than GPS tagging); ·         Covers Data-Driven as well as Semantic Location Estimation.

  8. Digital confocal microscopy through a multimode fiber

    CERN Document Server

    Loterie, Damien; Papadopoulos, Ioannis; Goy, Alexandre; Psaltis, Demetri; Moser, Christophe

    2015-01-01

    Acquiring high-contrast optical images deep inside biological tissues is still a challenging issue. Confocal microscopy is an important tool for biomedical imaging since it improves image quality by rejecting background signals. On the other hand, it suffers from low sensitivities in deep tissues due to light scattering. Recently, multimode fibers have provided a new paradigm for minimally invasive endoscopic imaging by controlling light propagation through them. Here we introduce a combined imaging technique where confocal images of a human epithelial cell are acquired through a multimode fiber. We achieve this by digitally engineering the excitation wavefront and then applying a virtual digital pinhole on the collected signal. In this way, we are able to acquire images through the fiber with significantly increased contrast.

  9. The multimodal argumentation of persuasive counter discourses

    DEFF Research Database (Denmark)

    Maier, Carmen Daniela

    with the characteristics and potential fallacies of the advertising discourse of commercials. The original advertising discourse is deconstructed and reconstructed with additional visual material in front of the viewers’ eyes who are instructed by a voiceover narrator what to look at and how to identify and decode...... and critical participants in the process of message understanding. In this paper, I explore the Media Bites videos that identify and discuss problematic gender issues in commercials advertising various products. I adopt a multimodal approach in my discourse analysis and I establish which semiotic modes...... are given prominence in the argumentation by examining their complex interplay and functional differentiation. The ways in which speech, writing and images articulate the counter discourse occupy a central position in the analysis. A special focus is put on the multimodal configuration of specific...

  10. The Sloan Lens ACS Survey. V. The full ACS strong-lens sample

    NARCIS (Netherlands)

    Bolton, Adam S.; Burles, Scott; Koopmans, Leon V. E.; Treu, Tommaso; Gavazzi, Raphael; Moustakas, Leonidas A.; Wayth, Randall; Schlegel, David J.

    2008-01-01

    We present the definitive data for the full sample of 131 strong gravitational lens candidates observed with the Advanced Camera for Surveys (ACS) aboard the Hubble Space Telescope by the Sloan Lens ACS (SLACS) Survey. All targets were selected for higher redshift emission lines and lower redshift

  11. Effect of infusion bottle height on lens power after lens refilling with and without a plug

    NARCIS (Netherlands)

    Koopmans, SA; Terwee, T; Haitjema, HJ; Kooijman, AC; Barkhof, J

    2003-01-01

    Purpose: To evaluate the influence of intraoperative infusion bottle height on the power of refilled pig lenses. Setting: Research Laboratory, Pharmacia Intraocular Lens Manufacturing Plant, Groningen, The Netherlands. Methods: This study comprised 2 groups of pig eyes. In 1 group, the lens was refi

  12. Gravitational binary-lens events with prominent effects of lens orbital motion

    Energy Technology Data Exchange (ETDEWEB)

    Park, H.; Han, C.; Choi, J.-Y. [Department of Physics, Institute for Astrophysics, Chungbuk National University, Cheongju 371-763 (Korea, Republic of); Udalski, A.; Szymański, M. K.; Kubiak, M.; Soszyński, I.; Pietrzyński, G.; Poleski, R.; Ulaczyk, K.; Pietrukowicz, P.; Kozłowski, S.; Skowron, J.; Wyrzykowski, Ł. [Warsaw University Observatory, Al. Ujazdowskie 4, 00-478 Warszawa (Poland); Gould, A.; Gaudi, B. S. [Department of Astronomy, The Ohio State University, 140 West 18th Avenue, Columbus, OH 43210 (United States); Beaulieu, J.-P. [Institut d' Astrophysique de Paris, UMR 7095 CNRS-Université Pierre and Marie Curie, 98bis Bd Arago, F-75014 Paris (France); Tsapras, Y. [Las Cumbres Observatory Global Telescope Network, 6740 Cortona Drive, Suite 102, Goleta, CA 93117 (United States); Depoy, D. L. [Department of Physics and Astronomy, Texas A and M University, College Station, TX 77843 (United States); Dong, Subo [Institute for Advanced Study, Einstein Drive, Princeton, NJ 08540 (United States); Collaboration: OGLE Collaboration; μFUN Collaboration; PLANET Collaboration; RoboNet Collaboration; and others

    2013-12-01

    Gravitational microlensing events produced by lenses composed of binary masses are important because they provide a major channel for determining physical parameters of lenses. In this work, we analyze the light curves of two binary-lens events, OGLE-2006-BLG-277 and OGLE-2012-BLG-0031, for which the light curves exhibit strong deviations from standard models. From modeling considering various second-order effects, we find that the deviations are mostly explained by the effect of the lens orbital motion. We also find that lens parallax effects can mimic orbital effects to some extent. This implies that modeling light curves of binary-lens events not considering orbital effects can result in lens parallaxes that are substantially different from actual values and thus wrong determinations of physical lens parameters. This demonstrates the importance of routine consideration of orbital effects in interpreting light curves of binary-lens events. It is found that the lens of OGLE-2006-BLG-277 is a binary composed of a low-mass star and a brown dwarf companion.

  13. The Sloan Lens ACS Survey. V. The full ACS strong-lens sample

    NARCIS (Netherlands)

    Bolton, Adam S.; Burles, Scott; Koopmans, Leon V. E.; Treu, Tommaso; Gavazzi, Raphael; Moustakas, Leonidas A.; Wayth, Randall; Schlegel, David J.

    2008-01-01

    We present the definitive data for the full sample of 131 strong gravitational lens candidates observed with the Advanced Camera for Surveys (ACS) aboard the Hubble Space Telescope by the Sloan Lens ACS (SLACS) Survey. All targets were selected for higher redshift emission lines and lower redshift c

  14. DISSECTING THE GRAVITATIONAL LENS B1608+656. I. LENS POTENTIAL RECONSTRUCTION

    NARCIS (Netherlands)

    Suyu, S. H.; Marshall, P. J.; Blandford, R. D.; Fassnacht, C. D.; Koopmans, L. V. E.; McKean, J. P.; Treu, T.

    2009-01-01

    Strong gravitational lensing is a powerful technique for probing galaxy mass distributions and for measuring cosmological parameters. Lens systems with extended source-intensity distributions are particularly useful for this purpose since they provide additional constraints on the lens potential ( m

  15. Multimode FPGA with Flexible Embedded FPUS

    OpenAIRE

    G.Murugaboopathi; S.Hariharasitaraman; Sankar, G.

    2012-01-01

    The Performance of field-programmable gate arrays used for Floating-point applications are poor due to complexity of floating-point arithmetic. Implementing floating-point units on FPGAs consume a large amount of resources. This makes FPGAs less attractive for use in floating-point intensive applications. There is a need for embedded FPUs in FPGAs. We proposed a flexible multimode embedded FPU for FPGAs that can be configured to perform a wide range of operations. The floatingpoint adder and ...

  16. Multimodal Sensor Fusion for Personnel Detection

    Science.gov (United States)

    2011-07-01

    Multimodal Sensor Fusion for Personnel Detection Xin Jin Shalabh Gupta Asok Ray Department of Mechanical Engineering The Pennsylvania State...have con- sidered relations taken only two at a time, but we propose to explore relations between higher order cliques as future work. D. Feature...detection,” IEEE Transactions on Pattern Analysis and Machine Intelligence, vol. 23, no. 6, pp. 577–589, 2001. [11] A. Ray , “Symbolic dynamic analysis

  17. Multimodal Semantic Analysis of Public Transport Movements

    Science.gov (United States)

    Halb, Wolfgang; Neuschmied, Helmut

    We present a system for multimodal, semantic analysis of person movements that incorporates data from surveillance cameras, weather sensors, and third-party information providers. The interactive demonstration will show the automated creation of a survey of passenger transfer behavior at a public transport hub. Such information is vital for public transportation planning and the presented approach increases the cost-effectiveness and data accuracy as compared to traditional methods.

  18. Multimodal CARS microscopy of structured carbohydrate biopolymers

    OpenAIRE

    Slepkov, Aaron D.; Ridsdale, Andrew; Pegoraro, Adrian F.; Moffatt, Douglas J.; Stolow, Albert

    2010-01-01

    We demonstrate the utility of multimodal coherent anti-Stokes Raman scattering (CARS) microscopy for the study of structured condensed carbohydrate systems. Simultaneous second-harmonic generation (SHG) and spectrally-scanned CARS microscopy was used to elucidate structure, alignment, and density in cellulose cotton fibers and in starch grains undergoing rapid heat-moisture swelling. Our results suggest that CARS response of the O-H stretch region (3000 cm−1–3400 cm−1), together with the comm...

  19. Performance Enhancement Of Multimodal Biometrics Using Cryptosystem

    Directory of Open Access Journals (Sweden)

    Muskaan,

    2015-06-01

    Full Text Available Multimodal biometrics means the unification of two or more uni modal biometrics so as to make the system more reliable and secure. Such systems promise better security. This study is a blend of iris and fingerprint recognition technique and their fusion at feature level. Our work comprises of two main sections: feature extraction of both modalities and fusing them before matching and finally application of an encryption technique to enhance the security of the fused template.

  20. Multi-Modal Interaction for Robotic Mules

    Science.gov (United States)

    2014-02-26

    Multi-Modal Interaction for Robotic Mules Glenn Taylor, Mike Quist , Matt Lanting, Cory Dunham, Patrick Theisen, Paul Muench Abstract...Taylor, Mike Quist , Matt Lanting, Cory Dunham, and Patrick Theisen are with Soar Technology, Inc. (corresponding author: 734-887- 7620; email: glenn...soartech.com; quist @soartech.com; matt.lanting@soartech.com; dunham@soartech.com; patrick.theisen@soartech.com Paul Muench is with US Army TARDEC

  1. Research Progress on Multimode Interference Switches

    Institute of Scientific and Technical Information of China (English)

    GAO Qing; SHENG Zhi-rui; JIANG Xiao-qing; WANG Ming-hua

    2005-01-01

    Optical switches are key components for constructing optical communication networks, so it is necessary to design optical switches and optical switch arrays with high performance and low cost. As one type of optical switches, the multimode interference(MMI) switches have received considerable attention due to their unique merits. The structures and operation principles of various types of MMI switches are introduced,and the recent progresses of MMI switches are also discussed.

  2. Automatic Multimodal Cognitive Load Measurement (AMCLM)

    Science.gov (United States)

    2011-06-01

    Final Project Report Grant AOARD-10-4029 Automatic Multimodal Cognitive Load Measurement (AMCLM) June 2011 NICTA DSIM Team...collection of information if it does not display a currently valid OMB control number. 1. REPORT DATE 12 AUG 2011 2. REPORT TYPE 3. DATES COVERED 4...human-computer interface, such as air traffic control , in-car safety and electronic games. By quantifying the mental efforts of a person when

  3. Fiber Optic Temperature Sensor Based on Multimode Interference Effects

    Energy Technology Data Exchange (ETDEWEB)

    Aguilar-Soto, J G; Antonio-Lopez, J E; Sanchez-Mondragon, J J [Photonics and Optical Physics Laboratory, Optics Department, INAOE Apdo. Postal 51 and 216, Tonantzintla, Puebla 72000 (Mexico); May-Arrioja, D A, E-mail: darrioja@uat.edu.mx

    2011-01-01

    A novel fiber optic temperature sensor based on multimode interference was designed, fabricated and tested. The sensor is very simple and inexpensive since we only need to splice a section of multimode fiber between two single mode fibers. Using this device a sensing range of 25 deg. C to 375 deg. C is demonstrated. We should also highlight that due to the pass-band filter response of MMI devices, multiplexing is rather simple by just changing the length of the multimode section.

  4. Softec HD hydrophilic acrylic intraocular lens: biocompatibility and precision

    Directory of Open Access Journals (Sweden)

    Ladan Espandar

    2011-01-01

    Full Text Available Ladan Espandar1, Shameema Sikder2, Majid Moshirfar31Department of Ophthalmology, Tulane University, New Orleans, LA, USA; 2Wilmer Eye Institute, Johns Hopkins University, Baltimore, MD, USA; 3John A Moran Eye Center, University of Utah, Salt Lake City, UT, USAAbstract: Intraocular lens development is driven by higher patient expectations for ideal visual outcomes. The recently US Food and Drug Administration-approved Softec HD™ lens is an aspheric, hydrophilic acrylic intraocular lens (IOL. The hydrophilic design of the lens is optimized to address dysphotopsia while maintaining biocompatibility, optical clarity, resistance to damage, and resistance to biocontamination. Aspheric lenses decrease postoperative spherical aberration. The addition of the Softec lens provides clinicians with another option for IOL placement; however, randomized comparative studies of this lens to others already on the market remain to be completed.Keywords: hydrophilic acrylic intraocular lens, Softec HD intraocular lens, aspheric intraocular lens, IOL

  5. An improved spinning lens test to determine the stiffness of the human lens

    Science.gov (United States)

    Burd, H.J.; Wilde, G.S.; Judge, S.J.

    2011-01-01

    It is widely accepted that age-related changes in lens stiffness are significant for the development of presbyopia. However, precise details on the relative importance of age-related changes in the stiffness of the lens, in comparison with other potential mechanisms for the development of presbyopia, have not yet been established. One contributing factor to this uncertainty is the paucity and variability of experimental data on lens stiffness. The available published data generally indicate that stiffness varies spatially within the lens and that stiffness parameters tend to increase with age. However, considerable differences exist between these published data sets, both qualitatively and quantitatively. The current paper describes new and improved methods, based on the spinning lens approach pioneered by Fisher, R.F. (1971) ‘The elastic constants of the human lens’, Journal of Physiology, 212, 147–180, to make measurements on the stiffness of the human lens. These new procedures have been developed in an attempt to eliminate, or at least substantially reduce, various systematic errors in Fisher’s original experiment. An improved test rig has been constructed and a new modelling procedure for determining lens stiffness parameters from observations made during the test has been devised. The experiment involves mounting a human lens on a vertical rotor so that the lens spins on its optical axis (typically at 1000 rpm). An automatic imaging system is used to capture the outline of the lens, while it is rotating, at pre-determined angular orientations. These images are used to quantify the deformations developed in the lens as a consequence of the centripetal forces induced by the rotation. Lens stiffness is inferred using axisymmetric finite element inverse analysis in which a nearly-incompressible neo-Hookean constitutive model is used to represent the mechanics of the lens. A numerical optimisation procedure is used to determine the stiffness parameters

  6. Corneal topography and soft contact lens fit.

    Science.gov (United States)

    Young, Graeme; Schnider, Cristina; Hunt, Chris; Efron, Suzanne

    2010-05-01

    To determine which ocular topography variables affect soft contact lens fit. Fifty subjects each wore three pairs of soft lenses in random succession (Vistakon Acuvue 2, Vistakon Acuvue Advance, Ciba Vision Night & Day), and various aspects of lens fit were evaluated. The steeper base curves of each type were worn in one eye and the flatter base curves in the other eye. Corneal topography data were collected using a Medmont E300 corneal topographer (Camberwell, Australia). Corneal curvature, shape factor (SF), and corneal height were measured over a 10 mm chord and also over the maximum measurable diameter. These were measured in the horizontal, vertical, steepest, and flattest meridians. With each lens type, the steeper base curve provided the best fit on the greatest proportion of eyes and the significant differences in various aspects of fit were noted between base curves. For each lens type, there was no significant difference in mean K-reading between those eyes best fit with the steeper base curve and those eyes best fit with the flatter base curve. Two of the lenses showed a positive correlation between centration and horizontal corneal height (maximum), whereas one lens showed a negative correlation between centration and horizontal SF (SF = e). Several lenses showed a positive correlation between post-blink movement and horizontal or vertical corneal SF. The measurement of corneal topography using current Placido disc instrumentation allows a better prediction of soft lens fit than by keratometry, but it is not reliable enough to enable accurate selection of the best fitting base curve. Some correlations are evident between corneal measurements; however, trial fitting remains the method of choice for selection of soft lens base curve.

  7. Medical Image Retrieval: A Multimodal Approach.

    Science.gov (United States)

    Cao, Yu; Steffey, Shawn; He, Jianbiao; Xiao, Degui; Tao, Cui; Chen, Ping; Müller, Henning

    2014-01-01

    Medical imaging is becoming a vital component of war on cancer. Tremendous amounts of medical image data are captured and recorded in a digital format during cancer care and cancer research. Facing such an unprecedented volume of image data with heterogeneous image modalities, it is necessary to develop effective and efficient content-based medical image retrieval systems for cancer clinical practice and research. While substantial progress has been made in different areas of content-based image retrieval (CBIR) research, direct applications of existing CBIR techniques to the medical images produced unsatisfactory results, because of the unique characteristics of medical images. In this paper, we develop a new multimodal medical image retrieval approach based on the recent advances in the statistical graphic model and deep learning. Specifically, we first investigate a new extended probabilistic Latent Semantic Analysis model to integrate the visual and textual information from medical images to bridge the semantic gap. We then develop a new deep Boltzmann machine-based multimodal learning model to learn the joint density model from multimodal information in order to derive the missing modality. Experimental results with large volume of real-world medical images have shown that our new approach is a promising solution for the next-generation medical imaging indexing and retrieval system.

  8. Next Generation Multi-mode Remote Sensing Radar Project

    Data.gov (United States)

    National Aeronautics and Space Administration — This effort leverages ESTO and SBIR investments aimed at enabling fully polarimetric digital beamforming multimode radar, high resolution (wideband) measurements,...

  9. Multimodal integration of anatomy and physiology classes: How instructors utilize multimodal teaching in their classrooms

    Science.gov (United States)

    McGraw, Gerald M., Jr.

    Multimodality is the theory of communication as it applies to social and educational semiotics (making meaning through the use of multiple signs and symbols). The term multimodality describes a communication methodology that includes multiple textual, aural, and visual applications (modes) that are woven together to create what is referred to as an artifact. Multimodal teaching methodology attempts to create a deeper meaning to course content by activating the higher cognitive areas of the student's brain, creating a more sustained retention of the information (Murray, 2009). The introduction of multimodality educational methodologies as a means to more optimally engage students has been documented within educational literature. However, studies analyzing the distribution and penetration into basic sciences, more specifically anatomy and physiology, have not been forthcoming. This study used a quantitative survey design to determine the degree to which instructors integrated multimodality teaching practices into their course curricula. The instrument used for the study was designed by the researcher based on evidence found in the literature and sent to members of three associations/societies for anatomy and physiology instructors: the Human Anatomy and Physiology Society; the iTeach Anatomy & Physiology Collaborate; and the American Physiology Society. Respondents totaled 182 instructor members of two- and four-year, private and public higher learning colleges collected from the three organizations collectively with over 13,500 members in over 925 higher learning institutions nationwide. The study concluded that the expansion of multimodal methodologies into anatomy and physiology classrooms is at the beginning of the process and that there is ample opportunity for expansion. Instructors continue to use lecture as their primary means of interaction with students. Email is still the major form of out-of-class communication for full-time instructors. Instructors with

  10. Multimode fiber amplifier with tunable modal gain using a reconfigurable multimode pump.

    Science.gov (United States)

    Bai, Neng; Ip, Ezra; Wang, Ting; Li, Guifang

    2011-08-15

    We propose a method for controlling modal gain in a multimode Erbium-doped fiber amplifier (MM-EDFA) by tuning the mode content of a multimode pump. By adjusting the powers and orientation of input pump modes, modal dependent gain can be tuned over a large dynamic range. Performance impacts due to excitation of undesired pump modes, mode coupling and macro-bending loss within the erbium-doped fiber are also investigated. The MM-EDFA may potentially be a key element for long haul mode-division multiplexed transmission.

  11. [Representation and mathematical analysis of human crystalline lens].

    Science.gov (United States)

    Tălu, Stefan; Giovanzana, Stefano; Tălu, Mihai

    2011-01-01

    The surface of human crystalline lens can be described and analyzed using mathematical models based on parametric representations, used in biomechanical studies and 3D solid modeling of the lens. The mathematical models used in lens biomechanics allow the study and the behavior of crystalline lens on variables and complex dynamic loads. Also, the lens biomechanics has the potential to improve the results in the development of intraocular lenses and cataract surgery. The paper presents the most representative mathematical models currently used for the modeling of human crystalline lens, both optically and biomechanically.

  12. Imaging characteristics of a volume holographic lens

    Science.gov (United States)

    Yang, Jing; Jiang, Zhu-qing; Xu, Zhi-qiang; Liu, Shao-jie; Sun, Ya-jun; Tao, Shi-quan

    2009-07-01

    A volume holographic grating lens can reconstruct the three-dimensional information by conducting multiple optical slicing of an object based on Bragg selectivity of the volume holographic grating. In this paper, we employ the point-spread function of volume holographic imaging system to theoretically analyze its imaging resolution. In the experiments, the volume holographic gratings are made with a spherical reference (SR) and a planar reference (PR), respectively, and used as volume holographic imaging lens in our imaging system. The longitudinal and lateral defocusing characteristics of volume holographic lens with SR and with PR are investigated experimentally by displacing the interested objects from original reference location, respectively. The effects of the parameters of the volume holographic lens on the longitudinal and lateral resolution are also discussed. The experimental results show that increasing the size of the volume holographic lens can improve the depth resolution, and in particular, it has greater influence on SR VHI. The lateral selectivity of SR VHI is more sensitive than that of PR VHI, and the Bragg degenerate diffraction of PR VHI on the y axis is obviously observed.

  13. Apoptosis in the lens anlage of the heritable lens aplastic mouse (lap mouse).

    Science.gov (United States)

    Aso, S; Tashiro, M; Baba, R; Sawaki, M; Noda, S; Fujita, M

    1998-08-01

    Adult homozygous lap mice show various eye abnormalities, such as aphakia, retinal disorganization, and dysplasia of the cornea and anterior chamber. In the fetal eye of a homozygous lap mouse, the lens placode seems to develop normally. However, the lens vesicle progresses abnormally to form a mass of cells without a cavity, and the mass vanishes soon afterward. We examined cell death in the lens anlage of this mutant. The lens anlagen of homozygous lap and normal mice from days 10 to 12 of gestation were observed by light microscopy after DNA end-labeling by immunohistochemistry and by transmission electron microscopy. By light microscopy, a slight frequency of cell death was detected in the lens anlage encircling the surface ectoderm and in the anlage or in the anlage of both homozygous lap mice and normal mice at day 10 of gestation. Cell death was seen in the lens anlage encircling the surface ectoderm in the normal mouse and sporadically in the anlage of the homozygous lap mouse at day 10.5 of gestation. Cell death was visible at the area of the lens vesicle attached to the surface ectoderm and encircling the surrounding surface ectoderm in the normal mouse, and in the lens anlage encircling the surface ectoderm and the apex areas of the lens anlage in the homozygous lap mouse at day 11 of gestation. At day 12 of gestation, almost no cell death was observed in the lens anlage of the normal mouse. However, extensive areas of cell death were still seen in the lens anlage at its apex, at the inner region, and encircling the surface ectoderm in the homozygous lap mouse. Electron microscopic observation showed that the dead cells observed in the lens anlagen by light microscopy in normal and lap mice are the result of apoptosis. In lap mice, cells with cytoplasmic condensation were observed mainly at days 10 and 10.5 of gestation. Many apoptotic bodies which had been phagocytosed by adjacent cells were seen predominantly at day 11 of gestation. At day 12 of

  14. An inverse and analytic lens design method

    CERN Document Server

    Lu, Yang

    2016-01-01

    Traditional lens design is a numerical and forward process based on ray tracing and aberration theory. This method has limitations because the initial configuration of the lens has to be specified and the aberrations of the lenses have to considered. This paper is an initial attempt to investigate an analytic and inverse lens design method, called Lagrange, to overcome these barriers. Lagrange method tries to build differential equations in terms of the system parameters and the system input and output (object and image). The generalized Snell's law in three dimensional space and the normal of a surface in fundamental differential geometry are applied. Based on the Lagrange method equations for a single surface system are derived which can perfectly image a point object.

  15. 3D printed helical antenna with lens

    KAUST Repository

    Farooqui, Muhammad Fahad

    2016-12-19

    The gain of an antenna can be enhanced through the integration of a lens, however this technique has traditionally been restricted to planar antennas due to fabrication limitations of standard manufacturing processes. Here, with a unique combination of 3D and 2D inkjet printing of dielectric and metallic inks respectively, we demonstrate a Fresnel lens that has been monolithically integrated to a non-planar antenna (helix) for the first time. Antenna measurements show that the integration of a Fresnel lens enhances the gain of a 2-turn helix by around 4.6 dB giving a peak gain of about 12.9 dBi at 8.8 GHz.

  16. Catadioptric aberration correction in cathode lens microscopy

    Energy Technology Data Exchange (ETDEWEB)

    Tromp, R.M. [IBM T.J. Watson Research Center, PO Box 218, Yorktown Heights, NY 10598 (United States); Kamerlingh Onnes Laboratory, Leiden Institute of Physics, Niels Bohrweg 2, 2333 CA Leiden (Netherlands)

    2015-04-15

    In this paper I briefly review the use of electrostatic electron mirrors to correct the aberrations of the cathode lens objective lens in low energy electron microscope (LEEM) and photo electron emission microscope (PEEM) instruments. These catadioptric systems, combining electrostatic lens elements with a reflecting mirror, offer a compact solution, allowing simultaneous and independent correction of both spherical and chromatic aberrations. A comparison with catadioptric systems in light optics informs our understanding of the working principles behind aberration correction with electron mirrors, and may point the way to further improvements in the latter. With additional developments in detector technology, 1 nm spatial resolution in LEEM appears to be within reach. - Highlights: • The use of electron mirrors for aberration correction in LEEM/PEEM is reviewed. • A comparison is made with similar systems in light optics. • Conditions for 1 nm spatial resolution are discussed.

  17. Louvre-Lens : le Louvre autrement

    OpenAIRE

    Audrey Bodéré

    2010-01-01

    ∙ Quels sont les enjeux du projet Louvre-Lens pour le Musée du Louvre ? Par ce projet, le Louvre participe tant à la politique de décentralisation qu’à une volonté de démocratisation culturelle, en allant à la rencontre de nouveaux publics. Mais le projet scientifique et culturel du Louvre-Lens (PSC) précise aussi que l'un des principaux défis est d'oser le « Louvre autrement ». La présentation des collections est donc repensée pour traduire le monde Louvre à Lens. Le lien entre le Louvre Par...

  18. Louvre-Lens : le Louvre autrement

    Directory of Open Access Journals (Sweden)

    Audrey Bodéré

    2010-04-01

    Full Text Available ∙ Quels sont les enjeux du projet Louvre-Lens pour le Musée du Louvre ? Par ce projet, le Louvre participe tant à la politique de décentralisation qu’à une volonté de démocratisation culturelle, en allant à la rencontre de nouveaux publics. Mais le projet scientifique et culturel du Louvre-Lens (PSC précise aussi que l'un des principaux défis est d'oser le « Louvre autrement ». La présentation des collections est donc repensée pour traduire le monde Louvre à Lens. Le lien entre le Louvre Par...

  19. Image watermarking against lens flare effects

    Science.gov (United States)

    Chotikawanid, Piyanart; Amornraksa, Thumrongrat

    2017-02-01

    Lens flare effects in various photo and camera software nowadays can partially or fully damage the watermark information within the watermarked image. We propose in this paper a spatial domain based image watermarking against lens flare effects. The watermark embedding is based on the modification of the saturation color component in HSV color space of a host image. For watermark extraction, a homomorphic filter is used to predict the original embedding component from the watermarked component, and the watermark is blindly recovered by differentiating both components. The watermarked image's quality is evaluated by wPSNR, while the extracted watermark's accuracy is evaluated by NC. The experimental results against various types of lens flare effects from both computer software and mobile application showed that our proposed method outperformed the previous methods.

  20. The Frontier Fields Lens Modeling Comparison Project

    CERN Document Server

    Meneghetti, M; Coe, D; Contini, E; De Lucia, G; Giocoli, C; Acebron, A; Borgani, S; Bradac, M; Diego, J M; Hoag, A; Ishigaki, M; Johnson, T L; Jullo, E; Kawamata, R; Lam, D; Limousin, M; Liesenborgs, J; Oguri, M; Sebesta, K; Sharon, K; Williams, L L R; Zitrin, A

    2016-01-01

    Gravitational lensing by clusters of galaxies offers a powerful probe of their structure and mass distribution. Deriving a lens magnification map for a galaxy cluster is a classic inversion problem and many methods have been developed over the past two decades to solve it. Several research groups have developed techniques independently to map the predominantly dark matter distribution in cluster lenses. While these methods have all provided remarkably high precision mass maps, particularly with exquisite imaging data from the Hubble Space Telescope (HST), the reconstructions themselves have never been directly compared. In this paper, we report the results of comparing various independent lens modeling techniques employed by individual research groups in the community. Here we present for the first time a detailed and robust comparison of methodologies for fidelity, accuracy and precision. For this collaborative exercise, the lens modeling community was provided simulated cluster images -- of two clusters Are...

  1. Analytic Models of Plausible Gravitational Lens Potentials

    Energy Technology Data Exchange (ETDEWEB)

    Baltz, Edward A.; Marshall, Phil; Oguri, Masamune

    2007-05-04

    Gravitational lenses on galaxy scales are plausibly modeled as having ellipsoidal symmetry and a universal dark matter density profile, with a Sersic profile to describe the distribution of baryonic matter. Predicting all lensing effects requires knowledge of the total lens potential: in this work we give analytic forms for that of the above hybrid model. Emphasizing that complex lens potentials can be constructed from simpler components in linear combination, we provide a recipe for attaining elliptical symmetry in either projected mass or lens potential.We also provide analytic formulae for the lens potentials of Sersic profiles for integer and half-integer index. We then present formulae describing the gravitational lensing effects due to smoothly-truncated universal density profiles in cold dark matter model. For our isolated haloes the density profile falls off as radius to the minus fifth or seventh power beyond the tidal radius, functional forms that allow all orders of lens potential derivatives to be calculated analytically, while ensuring a non-divergent total mass. We show how the observables predicted by this profile differ from that of the original infinite-mass NFW profile. Expressions for the gravitational flexion are highlighted. We show how decreasing the tidal radius allows stripped haloes to be modeled, providing a framework for a fuller investigation of dark matter substructure in galaxies and clusters. Finally we remark on the need for finite mass halo profiles when doing cosmological ray-tracing simulations, and the need for readily-calculable higher order derivatives of the lens potential when studying catastrophes in strong lenses.

  2. Photonic crystal based polarization insensitive flat lens

    Science.gov (United States)

    Turduev, M.; Bor, E.; Kurt, H.

    2017-07-01

    The paper proposes a new design of an inhomogeneous artificially created photonic crystal lens structure consisting of annular dielectric rods to efficiently focus both transverse electric and transverse magnetic polarizations of light into the same focal point. The locations of each individual cell that contains the annular dielectric rods are determined according to a nonlinear distribution function. The inner and outer radii of the annular photonic dielectric rods are optimized with respect to the polarization insensitive frequency response of the transmission spectrum of the lens structure. The physical background of the polarization insensitive focusing mechanism is investigated in both spatial and frequency domains. Moreover, polarization independent wavefront transformation/focusing has been explored in detail by investigating the dispersion relation of the structure. Corresponding phase index distribution of the lens is attained for polarization insensitive normalized frequency range of a/λ  =  0.280 and a/λ  =  0.300, where a denotes the lattice constant of the designed structure and λ denotes the wavelength of the incident light. We show the wave transformation performance and focal point movement dynamics for both polarizations of the lens structure by specially adjusting the length of the structure. The 3D finite-difference time domain numerical analysis is also performed to verifiy that the proposed design is able to focus the wave regardless of polarization into approximately the same focal point (difference between focal distances of both polarizations stays below 0.25λ) with an operating bandwidth of 4.30% between 1476 nm and 1541 nm at telecom wavelengths. The main superiorities of the proposed lens structure are being all dielectric and compact, and having flat front and back surfaces, rendering the proposed lens design more practical in the photonic integration process in various applications such as optical switch

  3. Intraocular Lens Calcification; a Clinicopathologic Report

    Directory of Open Access Journals (Sweden)

    Mozhgan Rezaei-Kanavi

    2009-04-01

    Full Text Available

    PURPOSE: To describe the clinical and pathological features of a case of hydrogel intraocular lens (IOL calcification. CASE REPORT: A 48-year-old man underwent explantation of a single-piece hydrophilic acrylic intraocular lens in his left eye because of decreased visual acuity and milky white opalescence of the IOL. The opacified lens was exchanged uneventfully with a hydrophobic acrylic IOL. Gross examination of the explanted IOL disclosed opacification of the optic and haptics. Full-thickness sections of the lens optic were stained with hematoxylin and eosin (H&E, von Kossa and Gram Tworts'. Microscopic examination of the sections revealed fine and diffuse basophilic granular deposits of variable size within the lens optic parallel to the lens curvature but separated from the surface by a moderately clear zone. The deposits were of high calcium content as evident by dark brown staining with von Kossa. Gram Tworts' staining disclosed no microorganisms. CONCLUSION: This report further contributes to the existing literature on hydrogel IOL calcification.

  4. Pulse transformer for the AA lithium lens

    CERN Multimedia

    1980-01-01

    The antiprotons emanating from the target were initially focused by a magnetic horn. Later on, a Li-lens was used during operation for the SPS collider, until 1992. A Li-rod (130 mm long, 34 mm in diameter) constituted the secondary of a 1:23 pulse-transformer. The half-sine pulse rose to 1000 kA in 900 microsec. The angular acceptance was 95 mrad. In operation after 1992, for LEAR only, a more modest Li-lens was used (155 mm long, diameter 20 mm, 480 kA, risetime 240 microsec, angular acceptance 75 mrad).

  5. Time resolved thermal lens in edible oils

    Science.gov (United States)

    Albuquerque, T. A. S.; Pedreira, P. R. B.; Medina, A. N.; Pereira, J. R. D.; Bento, A. C.; Baesso, M. L.

    2003-01-01

    In this work time resolved thermal lens spectrometry is applied to investigate the optical properties of the following edible oils: soya, sunflower, canola, and corn oils. The experiments were performed at room temperature using the mode mismatched thermal lens configuration. The results showed that when the time resolved procedure is adopted the technique can be applied to investigate the photosensitivity of edible oils. Soya oil presented a stronger photochemical reaction as compared to the other investigated samples. This observation may be relevant for future studies evaluating edible oils storage conditions and also may contribute to a better understanding of the physical and chemical properties of this important foodstuff.

  6. Fundamentals of concentric lens systems synthesis

    Science.gov (United States)

    Ezhova, Kseniia; Zverev, Victor; Tochilina, Tatiana; Tymoshchuk, Irina

    2016-09-01

    Introduction of coefficients defining the relationship of the radii of curvature of the surfaces of concentric optical systems, allowed the transformation of the obtained analytical relations in a system of two equations with two unknowns. It is shown that the existence of the solution of the system of equations determined by the optical constants of the selected lens material. The results of the analysis of the conditions of the chromatic aberration correction position and the sequence of obtaining of the system equations define the theoretical basis of the engineering method of parametric synthesis of concentric lens systems. Application of the developed method is illustrated by examples of calculation particular systems design build.

  7. Bilateral Pseudoexfoliation Deposits on Intraocular Lens Implants

    Directory of Open Access Journals (Sweden)

    Elena Bonafonte Marquez

    2015-01-01

    Full Text Available We present a rare case of bilateral pseudoexfoliative deposits on both intraocular lens (IOL implants in an 83-year-old woman with no other associated pathology, 5 years after cataract surgery. Pseudoexfoliation syndrome is the most common cause of secondary open-angle glaucoma worldwide and these deposits are usually found on the natural lens. The fact that pseudoexfoliative deposits have been found on IOL implants implies the need for a thorough examination in pseudophakic patients, for it could be the only sign of secondary glaucoma.

  8. Immunochemical analyses of soluble lens proteins in some marine fishes

    Digital Repository Service at National Institute of Oceanography (India)

    Menezes, M.R.

    Soluble eye lens proteins of 10 fishes, belonging to the families Clupeidae, Hemirhamphidae, Lactaridae, Scombridae, Stromatidae, Psettodidae, Bothidae and Soleidae were studied by immunoelectrophoresis using the lens antiserum of Sardinella...

  9. Experimental Contact Lens to Prevent Glaucoma-Induced Blindness

    Science.gov (United States)

    ... Home Page An Experimental Contact Lens to Prevent Glaucoma-Induced Blindness By Sharon Reynolds Posted January 23, 2014 An experimental contact lens design releases a glaucoma medicine at a steady rate for up to ...

  10. Observation of Multimode Solitons in Few-Mode Fiber

    CERN Document Server

    Zhu, Zimu; Christodoulides, Demetrios N; Wise, Frank W

    2016-01-01

    We experimentally isolate and directly observe multimode solitons in few-mode graded-index fiber. By varying the input energy and modal composition of the launched pulse, we observe a continuous variation of multimode solitons with different spatiotemporal properties. They exhibit an energy-volume relation that is distinct from those of single-mode and fully spatiotemporal solitons.

  11. Multimodal warnings to enhance risk communication and safety

    NARCIS (Netherlands)

    Haas, E.C.; Erp, J.B.F. van

    2014-01-01

    Multimodal warnings incorporate audio and/or skin-based (tactile) cues to supplement or replace visual cues in environments where the user’s visual perception is busy, impaired, or nonexistent. This paper describes characteristics of audio, tactile, and multimodal warning displays and their role in

  12. Fracturing Writing Spaces: Multimodal Storytelling Ignites Process Writing

    Science.gov (United States)

    Lenters, Kimberly; Winters, Kari-Lynn

    2013-01-01

    In this paper, we explore the affordances of literature-based, arts-infused and digital media processes for students, as multimodal practices take centre stage in an English Language Arts unit on fractured fairy tales. The study takes up the challenge of addressing multimodal literacy instruction and research in ways that utilize a range of…

  13. Instantiation of Multimodal Semiotic Systems in Science Classroom Discourse

    Science.gov (United States)

    Tang, Kok-Sing

    2013-01-01

    Science classroom discourse is inherently multimodal in that scientific meanings are made through an integration of multiple semiotic systems (e.g., language, diagrams, equations). Although some studies have described this multimodal nature, few have examined and explained the relationship between the integration of multiple semiotic systems and…

  14. Multimodal Teaching and Learning: Creating Spaces for Content Teachers

    Science.gov (United States)

    Thompson, Mary

    2008-01-01

    In this article, the author describes her multimodal teaching practices in her "Adolescent Literacy Methods" course at a graduate university in the United States. By doing so, she highlights content teacher's understanding and use of various multimodal texts to effectively teach adolescents inside the classroom. In lieu of this, she raises…

  15. Multimodal transports in the Unidted States and Europe

    DEFF Research Database (Denmark)

    Ulfbeck, Vibe Garf

    2009-01-01

    Transport law has traditionally been regarded as an international area of the law. The modern multimodal transport, combining different types of transports, has changed this. Multimodal transports are not regulated by any international conventions. In commercial practice, one liability model is p...

  16. Teaching Visual Texts with the Multimodal Analysis Software

    Science.gov (United States)

    Lim Fei, Victor; O'Halloran, Kay L.; Tan, Sabine; E., Marissa K. L.

    2015-01-01

    This exploratory study introduces the systemic approach and the explicit teaching of a meta-language to provide conceptual tools for students for the analysis and interpretation of multimodal texts. Equipping students with a set of specialised vocabulary with conventionalised meanings associated with specific choices in multimodal texts empowers…

  17. The semiotics of typography in literary texts. A multimodal approach

    DEFF Research Database (Denmark)

    Nørgaard, Nina

    2009-01-01

    to multimodal discourse proposed, for instance, by Kress & Van Leeuwen (2001) and Baldry & Thibault (2006), and, more specifically, the multimodal approach to typography suggested by Van Leeuwen (2005b; 2006), in order to sketch out a methodological framework applicable to the description and analysis...... of the semiotic potential of typography in literary texts....

  18. Composition at Washington State University: Building a Multimodal Bricolage

    Science.gov (United States)

    Ericsson, Patricia; Hunter, Leeann Downing; Macklin, Tialitha Michelle; Edwards, Elizabeth Sue

    2016-01-01

    Multimodal pedagogy is increasingly accepted among composition scholars. However, putting such pedagogy into practice presents significant challenges. In this profile of Washington State University's first-year composition program, we suggest a multi-vocal and multi-theoretical approach to addressing the challenges of multimodal pedagogy. Patricia…

  19. Cultural Shifts, Multimodal Representations, and Assessment Practices: A Case Study

    Science.gov (United States)

    Curwood, Jen Scott

    2012-01-01

    Multimodal texts involve the presence, absence, and co-occurrence of alphabetic text with visual, audio, tactile, gestural, and spatial representations. This article explores how teachers' evaluation of students' multimodal work can be understood in terms of cognition and culture. When teachers apply a paradigm of assessment rooted in print-based…

  20. A Multimodal Discourse Analysis of Tmall's Double Eleven Advertisement

    Science.gov (United States)

    Hu, Chunyu; Luo, Mengxi

    2016-01-01

    From the 1990s, the multimodal turn in discourse studies makes multimodal discourse analysis a popular topic in linguistics and communication studies. An important approach to applying Systemic Functional Linguistics to non-verbal modes is Visual Grammar initially proposed by Kress and van Leeuwen (1996). Considering that commercial advertisement…

  1. Multimodal network design for sustainable household plastic recycling

    NARCIS (Netherlands)

    Bing Xiaoyun, Xiaoyun; Groot, J.J.; Bloemhof, J.M.; Vorst, van der J.G.A.J.

    2013-01-01

    Purpose – This research studies a plastic recycling system from a reverse logistics angle and investigates the potential benefits of a multimodality strategy to the network design of plastic recycling. This research aims to quantify the impact of multimodality on the network, to provide decision

  2. Multimodal network design for sustainable household plastic recycling

    NARCIS (Netherlands)

    Bing Xiaoyun, Xiaoyun; Groot, J.J.; Bloemhof, J.M.; Vorst, van der J.G.A.J.

    2013-01-01

    Purpose – This research studies a plastic recycling system from a reverse logistics angle and investigates the potential benefits of a multimodality strategy to the network design of plastic recycling. This research aims to quantify the impact of multimodality on the network, to provide decision sup

  3. Composition 2.0: Toward a Multilingual and Multimodal Framework

    Science.gov (United States)

    Fraiberg, Steven

    2010-01-01

    This article argues that tracing multimodal-multilingual literacy practices across official and unofficial spaces is key to moving composition into the twenty-first century. Key to this remixing of the field is a situated framework that locates multimodal-multilingual activities in wider genre, cultural, national, and global ecologies. (Contains 3…

  4. A Multimodal Discourse Analysis of a Yoruba Song-Drama

    Science.gov (United States)

    Olateju, Moji. A.

    2015-01-01

    This paper presents a multimodal discourse analysis of a story that has been turned into a Yoruba song-drama, highlighting the ideational, interpersonal and textual aspects of the song-drama. The data is a short song-drama meant to teach children importunity, determination and hard work through persistence. The multimodal and narrative conventions…

  5. Using Multimodal Writing to Motivate Struggling Students to Write

    Science.gov (United States)

    Darrington, Brett; Dousay, Tonia

    2014-01-01

    One of the reasons that many secondary students fail English classes is because they are not motivated to write. This literature review was conducted to look into the use of multimodal works to increase the motivation for struggling students to write. Change theory was used to evaluate the benefits of multimodal works compared to more traditional…

  6. The semiotics of typography in literary texts. A multimodal approach

    DEFF Research Database (Denmark)

    Nørgaard, Nina

    2009-01-01

    to multimodal discourse proposed, for instance, by Kress & Van Leeuwen (2001) and Baldry & Thibault (2006), and, more specifically, the multimodal approach to typography suggested by Van Leeuwen (2005b; 2006), in order to sketch out a methodological framework applicable to the description and analysis...

  7. Generation of a hollow laser beam by a multimode fiber

    Institute of Scientific and Technical Information of China (English)

    Hongyu Ma; Huadong Cheng; Wenzhuo Zhang; Liang Liu; Yuzhu Wang

    2007-01-01

    A simple method to generate a hollow laser beam by multimode fiber is reported. A dark hollow laser beam is generated from a multimode fiber and the dependence of the output beam profile on the incident angle of laser beam is analyzed. The results show that this hollow laser beam can be used to trap and guide cold atoms.

  8. Phakic Pattern Pseudoexfoliation Material Accumulation on Intraocular Lens Surface

    Directory of Open Access Journals (Sweden)

    Emre Güler

    2014-03-01

    Full Text Available Pseudophakic pseudoexfoliation is the accumulation of pseudoexfoliation material on the intraocular lens. Most of the cases have showed scattered flecks of pseudoexfoliation material on the surface of the intraocular lens. However, the phakic pattern consisting of classic three-zone on the intraocular lens is rarely observed. In this case report, we describe a phakic pattern pseudoexfoliation material on the intraocular lens surface 8 years after cataract extraction. (Turk J Ophthalmol 2014; 44: 156-7

  9. Phakic Pattern Pseudoexfoliation Material Accumulation on Intraocular Lens Surface

    OpenAIRE

    Emre Güler; Aylin Tenlik; Tuba Kara Akyüz

    2014-01-01

    Pseudophakic pseudoexfoliation is the accumulation of pseudoexfoliation material on the intraocular lens. Most of the cases have showed scattered flecks of pseudoexfoliation material on the surface of the intraocular lens. However, the phakic pattern consisting of classic three-zone on the intraocular lens is rarely observed. In this case report, we describe a phakic pattern pseudoexfoliation material on the intraocular lens surface 8 years after cataract extraction. (Turk J Ophthalm...

  10. Lens autofluorescence is not increased at high altitude

    DEFF Research Database (Denmark)

    Kessel, Line; Kofoed, Peter Kristian; Zubieta-Calleja, Gustavo

    2010-01-01

    PURPOSE: To study the relation between ambient environmental ultraviolet radiation exposure and lens fluorescence. METHODS: Non-invasive lens fluorometry measurements were compared in healthy Bolivian and Danish subjects. Background ultraviolet radiation was 4.5 times higher in Bolivia than...... in Denmark. RESULTS: No significant differences in lens fluorescence or transmittance were found between Bolivian and Danish volunteers. CONCLUSION: Age-corrected lens fluorescence and transmittance were comparable for healthy participants living at high altitude near the equator and healthy volunteers...

  11. An Ultrasonic Lens Design Based on Prefractal Structures

    OpenAIRE

    Sergio Castiñeira-Ibáñez; Daniel Tarrazó-Serrano; Constanza Rubio; Pilar Candelas; Antonio Uris

    2016-01-01

    The improvement in focusing capabilities of a set of annular scatterers arranged in a fractal geometry is theoretically quantified in this work by means of the finite element method (FEM). Two different arrangements of rigid rings in water are used in the analysis. Thus, both a Fresnel ultrasonic lens and an arrangement of rigid rings based on Cantor prefractals are analyzed. Results show that the focusing capacity of the modified fractal lens is better than the Fresnel lens. This new lens is...

  12. New developments in multimodal clinical multiphoton tomography

    Science.gov (United States)

    König, Karsten

    2011-03-01

    80 years ago, the PhD student Maria Goeppert predicted in her thesis in Goettingen, Germany, two-photon effects. It took 30 years to prove her theory, and another three decades to realize the first two-photon microscope. With the beginning of this millennium, first clinical multiphoton tomographs started operation in research institutions, hospitals, and in the cosmetic industry. The multiphoton tomograph MPTflexTM with its miniaturized flexible scan head became the Prism-Award 2010 winner in the category Life Sciences. Multiphoton tomographs with its superior submicron spatial resolution can be upgraded to 5D imaging tools by adding spectral time-correlated single photon counting units. Furthermore, multimodal hybrid tomographs provide chemical fingerprinting and fast wide-field imaging. The world's first clinical CARS studies have been performed with a hybrid multimodal multiphoton tomograph in spring 2010. In particular, nonfluorescent lipids and water as well as mitochondrial fluorescent NAD(P)H, fluorescent elastin, keratin, and melanin as well as SHG-active collagen have been imaged in patients with dermatological disorders. Further multimodal approaches include the combination of multiphoton tomographs with low-resolution imaging tools such as ultrasound, optoacoustic, OCT, and dermoscopy systems. Multiphoton tomographs are currently employed in Australia, Japan, the US, and in several European countries for early diagnosis of skin cancer (malignant melanoma), optimization of treatment strategies (wound healing, dermatitis), and cosmetic research including long-term biosafety tests of ZnO sunscreen nanoparticles and the measurement of the stimulated biosynthesis of collagen by anti-ageing products.

  13. Partial order approach to compute shortest paths in multimodal networks

    CERN Document Server

    Ensor, Andrew

    2011-01-01

    Many networked systems involve multiple modes of transport. Such systems are called multimodal, and examples include logistic networks, biomedical phenomena, manufacturing process and telecommunication networks. Existing techniques for determining optimal paths in multimodal networks have either required heuristics or else application-specific constraints to obtain tractable problems, removing the multimodal traits of the network during analysis. In this paper weighted coloured--edge graphs are introduced to model multimodal networks, where colours represent the modes of transportation. Optimal paths are selected using a partial order that compares the weights in each colour, resulting in a Pareto optimal set of shortest paths. This approach is shown to be tractable through experimental analyses for random and real multimodal networks without the need to apply heuristics or constraints.

  14. Percorsi linguistici e semiotici: Critical Multimodal Analysis of Digital Discourse

    Directory of Open Access Journals (Sweden)

    edited by Ilaria Moschini

    2014-12-01

    Full Text Available The language section of LEA - edited by Ilaria Moschini - is dedicated to the Critical Multimodal Analysis of Digital Discourse, an approach that encompasses the linguistic and semiotic detailed investigation of texts within a socio-cultural perspective. It features an interview with Professor Theo van Leeuwen by Ilaria Moschini and four essays: “Retwitting, reposting, repinning; reshaping identities online: Towards a social semiotic multimodal analysis of digital remediation” by Elisabetta Adami; “Multimodal aspects of corporate social responsibility communication” by Carmen Daniela Maier; “Pervasive Technologies and the Paradoxes of Multimodal Digital Communication” by Sandra Petroni and “Can the powerless speak? Linguistic and multimodal corporate media manipulation in digital environments: the case of Malala Yousafzai” by Maria Grazia Sindoni. 

  15. Invariant measures on multimode quantum Gaussian states

    Science.gov (United States)

    Lupo, C.; Mancini, S.; De Pasquale, A.; Facchi, P.; Florio, G.; Pascazio, S.

    2012-12-01

    We derive the invariant measure on the manifold of multimode quantum Gaussian states, induced by the Haar measure on the group of Gaussian unitary transformations. To this end, by introducing a bipartition of the system in two disjoint subsystems, we use a parameterization highlighting the role of nonlocal degrees of freedom—the symplectic eigenvalues—which characterize quantum entanglement across the given bipartition. A finite measure is then obtained by imposing a physically motivated energy constraint. By averaging over the local degrees of freedom we finally derive the invariant distribution of the symplectic eigenvalues in some cases of particular interest for applications in quantum optics and quantum information.

  16. Invariant measures on multimode quantum Gaussian states

    CERN Document Server

    Lupo, C; De Pasquale, A; Facchi, P; Florio, G; Pascazio, S

    2012-01-01

    We derive the invariant measure on the manifold of multimode quantum Gaussian states, induced by the Haar measure on the group of Gaussian unitary transformations. To this end, by introducing a bipartition of the system in two disjoint subsystems, we use a parameterization highlighting the role of nonlocal degrees of freedom -- the symplectic eigenvalues -- which characterize quantum entanglement across the given bipartition. A finite measure is then obtained by imposing a physically motivated energy constraint. By averaging over the local degrees of freedom we finally derive the invariant distribution of the symplectic eigenvalues in some cases of particular interest or applications in quantum optics and quantum information.

  17. Invariant measures on multimode quantum Gaussian states

    Energy Technology Data Exchange (ETDEWEB)

    Lupo, C. [School of Science and Technology, Universita di Camerino, I-62032 Camerino (Italy); Mancini, S. [School of Science and Technology, Universita di Camerino, I-62032 Camerino (Italy); Istituto Nazionale di Fisica Nucleare, Sezione di Perugia, I-06123 Perugia (Italy); De Pasquale, A. [NEST, Scuola Normale Superiore and Istituto Nanoscienze-CNR, I-56126 Pisa (Italy); Facchi, P. [Dipartimento di Matematica and MECENAS, Universita di Bari, I-70125 Bari (Italy); Istituto Nazionale di Fisica Nucleare, Sezione di Bari, I-70126 Bari (Italy); Florio, G. [Istituto Nazionale di Fisica Nucleare, Sezione di Bari, I-70126 Bari (Italy); Museo Storico della Fisica e Centro Studi e Ricerche Enrico Fermi, Piazza del Viminale 1, I-00184 Roma (Italy); Dipartimento di Fisica and MECENAS, Universita di Bari, I-70126 Bari (Italy); Pascazio, S. [Istituto Nazionale di Fisica Nucleare, Sezione di Bari, I-70126 Bari (Italy); Dipartimento di Fisica and MECENAS, Universita di Bari, I-70126 Bari (Italy)

    2012-12-15

    We derive the invariant measure on the manifold of multimode quantum Gaussian states, induced by the Haar measure on the group of Gaussian unitary transformations. To this end, by introducing a bipartition of the system in two disjoint subsystems, we use a parameterization highlighting the role of nonlocal degrees of freedom-the symplectic eigenvalues-which characterize quantum entanglement across the given bipartition. A finite measure is then obtained by imposing a physically motivated energy constraint. By averaging over the local degrees of freedom we finally derive the invariant distribution of the symplectic eigenvalues in some cases of particular interest for applications in quantum optics and quantum information.

  18. Multimodal neuromonitoring in pediatric cardiac anesthesia

    Directory of Open Access Journals (Sweden)

    Alexander J. C. Mittnacht

    2014-01-01

    Full Text Available Despite significant improvements in overall outcome, neurological injury remains a feared complication following pediatric congenital heart surgery (CHS. Only if adverse events are detected early enough, can effective actions be initiated preventing potentially serious injury. The multifactorial etiology of neurological injury in CHS patients makes it unlikely that one single monitoring modality will be effective in capturing all possible threats. Improving current and developing new technologies and combining them according to the concept of multimodal monitoring may allow for early detection and possible intervention with the goal to further improve neurological outcome in children undergoing CHS.

  19. Multimodality imaging for resuscitated sudden cardiac death.

    Science.gov (United States)

    Chen, Yingming Amy; Deva, Djeven; Kirpalani, Anish; Prabhudesai, Vikram; Marcuzzi, Danny W; Graham, John J; Verma, Subodh; Jimenez-Juan, Laura; Yan, Andrew T

    2015-01-01

    We present a case that elegantly illustrates the utility of two novel noninvasive imaging techniques, computed tomography (CT) coronary angiography and cardiac MRI, in the diagnosis and management of a 27-year-old man with exertion-induced cardiac arrest caused by an anomalous right coronary artery. CT coronary angiography with 3D reformatting delineated the interarterial course of an anomalous right coronary artery compressed between the aorta and pulmonary artery, whereas cardiac MRI showed a small myocardial infarction in the right coronary artery territory not detected on echocardiography. This case highlights the value of novel multimodality imaging techniques in the risk stratification and management of patients with resuscitated cardiac arrest.

  20. Multimodal CARS microscopy of structured carbohydrate biopolymers

    Science.gov (United States)

    Slepkov, Aaron D.; Ridsdale, Andrew; Pegoraro, Adrian F.; Moffatt, Douglas J.; Stolow, Albert

    2010-01-01

    We demonstrate the utility of multimodal coherent anti-Stokes Raman scattering (CARS) microscopy for the study of structured condensed carbohydrate systems. Simultaneous second-harmonic generation (SHG) and spectrally-scanned CARS microscopy was used to elucidate structure, alignment, and density in cellulose cotton fibers and in starch grains undergoing rapid heat-moisture swelling. Our results suggest that CARS response of the O-H stretch region (3000 cm−1–3400 cm−1), together with the commonly-measured C-H stretch (2750 cm−1–2970 cm−1) and SHG provide potentially important structural information and contrast in these materials. PMID:21258555

  1. Ultrasonic motors using piezoelectric ceramic multimode vibrators.

    Science.gov (United States)

    Takano, T; Tomikawa, Y; Ogasawara, T; Sugawara, S; Konno, M

    1990-01-01

    The development is reported of an ultrasonic motor using piezoelectric ceramic multimode vibrators consisting of circular or annular plates in which degenerate horizontal vibration modes of the same or different form are used. Two orthogonal nonaxisymmetric vibration modes were used in the same-form case, and the combination of a nonaxisymmetric vibration mode and a radial vibration mode was used in the different-forms case. Some details of the motor design and its experimental characteristics are presented. The ultrasonic motor presented here has a special advantage in its thin construction.

  2. Multimodal CARS microscopy of structured carbohydrate biopolymers.

    Science.gov (United States)

    Slepkov, Aaron D; Ridsdale, Andrew; Pegoraro, Adrian F; Moffatt, Douglas J; Stolow, Albert

    2010-11-08

    We demonstrate the utility of multimodal coherent anti-Stokes Raman scattering (CARS) microscopy for the study of structured condensed carbohydrate systems. Simultaneous second-harmonic generation (SHG) and spectrally-scanned CARS microscopy was used to elucidate structure, alignment, and density in cellulose cotton fibers and in starch grains undergoing rapid heat-moisture swelling. Our results suggest that CARS response of the O-H stretch region (3000 cm(-1)-3400 cm(-1)), together with the commonly-measured C-H stretch (2750 cm(-1)-2970 cm(-1)) and SHG provide potentially important structural information and contrast in these materials.

  3. Multimodal Biometrics Recognition by Dimensionality Diminution Method

    Directory of Open Access Journals (Sweden)

    Suvarnsing Bhable

    2015-12-01

    Full Text Available Multimodal biometric system utilizes two or more character modalities, e.g., face, ear, and fingerprint, Signature, plamprint to improve the recognition accuracy of conventional unimodal methods. We propose a new dimensionality reduction method called Dimension Diminish Projection (DDP in this paper. DDP can not only preserve local information by capturing the intra-modal geometry, but also extract between-class relevant structures for classification effectively. Experimental results show that our proposed method performs better than other algorithms including PCA, LDA and MFA.

  4. Multimodality Imaging of Heart Valve Disease

    Energy Technology Data Exchange (ETDEWEB)

    Rajani, Ronak, E-mail: Dr.R.Rajani@gmail.com [Department of Cardiology, St. Thomas’ Hospital, London (United Kingdom); Khattar, Rajdeep [Department of Cardiology, Royal Brompton Hospital, London (United Kingdom); Chiribiri, Amedeo [Divisions of Imaging Sciences, The Rayne Institute, St. Thomas' Hospital, London (United Kingdom); Victor, Kelly; Chambers, John [Department of Cardiology, St. Thomas’ Hospital, London (United Kingdom)

    2014-09-15

    Unidentified heart valve disease is associated with a significant morbidity and mortality. It has therefore become important to accurately identify, assess and monitor patients with this condition in order that appropriate and timely intervention can occur. Although echocardiography has emerged as the predominant imaging modality for this purpose, recent advances in cardiac magnetic resonance and cardiac computed tomography indicate that they may have an important contribution to make. The current review describes the assessment of regurgitant and stenotic heart valves by multimodality imaging (echocardiography, cardiac computed tomography and cardiac magnetic resonance) and discusses their relative strengths and weaknesses.

  5. A novel multimodal CARS miniaturized microscope

    Science.gov (United States)

    Smith, Brett; Naji, Majid; Murugkar, Sangeeta; Brideau, Craig; Stys, Peter; Anis, Hanan

    2012-03-01

    We demonstrate the operation of a novel portable, fibre delivery miniaturized multimodal microscope (exoscope) for coherent anti-Stokes Raman scattering and two-photon excitation fluorescence imaging using a single Ti:sapphire femtosecond pulsed laser. This microscope features a large mode area photonic crystal fibre for light delivery, as well as biaxial scanning microelectromechanical system mirrors and custom miniaturized optics corrected for chromatic aberration. We demonstrate imaging of polystyrene beads, two photon excitation fluorescence beads in both forward and backward (epi) directions. This miniaturized exoscope will enable in-vivo imaging of rat spinal cord.

  6. Multimode Hong-Ou-Mandel interference

    CERN Document Server

    Walborn, S P; Pádua, S; Monken, C H

    2003-01-01

    We consider multimode two-photon interference at a beam splitter by photons created by spontaneous parametric down-conversion. The resulting interference pattern is shown to depend upon the transverse spatial symmetry of the pump beam. In an experiment, we employ the first-order Hermite-Gaussian modes in order to show that, by manipulating the pump beam, one can control the resulting two-photon interference behavior. We expect these results to play an important role in the engineering of quantum states of light for use in quantum information processing and quantum imaging.

  7. Surgical management of complications of multimodal therapy.

    Science.gov (United States)

    Chui, Chan-Hon

    2012-08-01

    Multimodality therapies that include surgery, chemotherapy, radiotherapy, and various newer forms of targeted therapies have been commonly applied in childhood cancers. Such modalities are associated with complications that may adversely affect the outcome of cancer treatment. Acute complications that require surgical management form the focus of our discussion. These patients are often compromised by immunosuppression, thrombocytopenia, and malnutrition. The complications discussed include typhlitis, invasive aspergillosis (IA), pancreatitis, hemorrhagic cystitis, gastrointestinal hemorrhage, necrotizing skin and soft-tissue infections, and perianal infection. Familiarity with the spectrum of complications and their appropriate management approaches will minimize the patients' morbidity.

  8. Multimodality Imaging of Heart Valve Disease

    Directory of Open Access Journals (Sweden)

    Ronak Rajani

    2014-09-01

    Full Text Available Unidentified heart valve disease is associated with a significant morbidity and mortality. It has therefore become important to accurately identify, assess and monitor patients with this condition in order that appropriate and timely intervention can occur. Although echocardiography has emerged as the predominant imaging modality for this purpose, recent advances in cardiac magnetic resonance and cardiac computed tomography indicate that they may have an important contribution to make. The current review describes the assessment of regurgitant and stenotic heart valves by multimodality imaging (echocardiography, cardiac computed tomography and cardiac magnetic resonance and discusses their relative strengths and weaknesses.

  9. MUVA: a MUltimodal Visceral design Ambient device

    DEFF Research Database (Denmark)

    Kivac, Robert; Klem, Sune Øllgaard; Olsen, Sophus Béneé

    2016-01-01

    This paper presents MUVA (MUltimodal Visceral design Ambient device), a prototype for a storytelling light- and sound-based ambient device. The aim of this device is to encourage social interaction and expand the emotional closeness in families with children where at least one parent has irregular...... work schedule. MUVA differs from the other ambient devices, because it is targeted to children, and it adopts a visceral design approach in order to be appealing to its users. It is a raindrop-shaped lamp, which features audio playing, while its light color is affected by the audio playing. MUVA can...

  10. Confocal microscopy via multimode fibers: fluorescence bandwidth

    Science.gov (United States)

    Loterie, Damien; Psaltis, Demetri; Moser, Christophe

    2016-03-01

    We recently described a method for confocal reflection imaging through fibers, as a way to increase contrast when imaging unstained biological specimens. Using a transmission matrix, focused spots can be created at the distal end of a fiber. The backscattered field coming back from the sample can be filtered using optical correlation to obtain spatial selectivity in the detection. In this proceedings article, we briefly review the working principle of this method, and we discuss how the scheme could be adapted to confocal fluorescence imaging. In particular, we show simulations of the achievable detection bandwidth when using step-index multimode fibers as imaging devices.

  11. 21 CFR 886.4300 - Intraocular lens guide.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Intraocular lens guide. 886.4300 Section 886.4300 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES OPHTHALMIC DEVICES Surgical Devices § 886.4300 Intraocular lens guide. (a) Identification. An intraocular lens guide is a device...

  12. 21 CFR 886.5916 - Rigid gas permeable contact lens.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Rigid gas permeable contact lens. 886.5916 Section... (CONTINUED) MEDICAL DEVICES OPHTHALMIC DEVICES Therapeutic Devices § 886.5916 Rigid gas permeable contact lens. (a) Identification. A rigid gas permeable contact lens is a device intended to be worn...

  13. 21 CFR 800.10 - Contact lens solutions; sterility.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Contact lens solutions; sterility. 800.10 Section...) MEDICAL DEVICES GENERAL Requirements for Specific Medical Devices § 800.10 Contact lens solutions... ophthalmic use, including contact lens solutions, should be sterile. It is further evident that...

  14. Analysis on shift and rotation of intraocular lens after phakic collamer lens implantation

    National Research Council Canada - National Science Library

    Yuan-Yuan Lu; Na Yang; Xue-Dong Li; Jun Kong

    2016-01-01

    .... In 1993, Staar Surgical(A.G. Nidau)introduced a modified intraocular collamer lens(ICL)for the correction of high myopia, which emerged as a safe and effective operation for moderate or high myopia gradually...

  15. Contact lens wear and microbial keratitis.

    Science.gov (United States)

    Ahuja, Markanday

    2002-11-01

    Common types of contact lens are hard, rigid gas-permeable or soft lenses. Most lenses are worn on a daily basis. Cosmetic lenses are worn for non-medical indications. Microbial keratitis, a rare but most significant complication is discussed in this article. Pseudomonas aeruginosa and staphylococci are the most common organisms cause infective keratitis. Fungi and acanthamoeba are also responsible. The causes of increased susceptibility to infection are poor lens hygiene, adhesion of bacteria to lens surface and hypoxia. Preventing measures to be taken while wearing contact lens are discussed in a nutshell. Ocular pain, conjunctival infection, photophobia, epiphora and reduced vision are some of the symptoms of corneal infection. Diagnostic laboratory investigations are to be carried out immediately when a microbial corneal ulcer is suspected. Acanthamoeba can be cultured from corneal scrapes. Immunologically based fluorescein labelling techniques appear to be more sensitive than simple staining. The treatment consists of medical and surgical intervention. Corneal thinning, descemetocele formation and perforation are possible complications.

  16. Application of optical polymers in lens design

    Science.gov (United States)

    Sultanova, Nina; Kasarova, Stefka; Nikolov, Ivan

    2016-03-01

    Optical, some thermal and elastic properties of optical polymers which are of importance in lens design are considered. Results are based on precise measurement of refraction of materials. Ultrasonic investigation of elastic moduli is carried out. Comparison to properties of Schott glasses is accomplished. Examples on the design of all-plastic and hybrid glass-plastic systems are presented.

  17. Testing and inspecting lens by holographic means

    Science.gov (United States)

    Hildebrand, Bernard P.

    1976-01-01

    Processes for the accurate, rapid and inexpensive testing and inspecting of oncave and convex lens surfaces through holographic means requiring no beamsplitters, mirrors or overpower optics, and wherein a hologram formed in accordance with one aspect of the invention contains the entire interferometer and serves as both a master and illuminating source for both concave and said convex surfaces to be so tested.

  18. Lens testing using total internal reflection holography

    Science.gov (United States)

    Hildebrand, Bernard P.

    1976-12-14

    Accurate, rapid and inexpensive testing and inspecting of lens surfaces tugh holographic means requiring no beamsplitters, mirrors or overpower optics, and wherein a hologram formed in accordance with one aspect of the invention contains the entire interferometer and serves as both a master and illuminating source for both concave and convex surfaces to be so tested.

  19. Contact lens rehabilitation following repaired corneal perforations

    Directory of Open Access Journals (Sweden)

    Sreenivas V

    2006-03-01

    Full Text Available Abstract Background Visual outcome following repair of post-traumatic corneal perforation may not be optimal due to presence of irregular keratometric astigmatism. We performed a study to evaluate and compare rigid gas permeable contact lens and spectacles in visual rehabilitation following perforating corneal injuries. Method Eyes that had undergone repair for corneal perforating injuries with or without lens aspiration were fitted rigid gas permeable contact lenses. The fitting pattern and the improvement in visual acuity by contact lens over spectacle correction were noted. Results Forty eyes of 40 patients that had undergone surgical repair of posttraumatic corneal perforations were fitted rigid gas permeable contact lenses for visual rehabilitation. Twenty-four eyes (60% required aphakic contact lenses. The best corrected visual acuity (BCVA of ≥ 6/18 in the snellen's acuity chart was seen in 10 (25% eyes with spectacle correction and 37 (92.5% eyes with the use of contact lens (p Conclusion Rigid gas permeable contact lenses are better means of rehabilitation in eyes that have an irregular cornea due to scars caused by perforating corneal injuries.

  20. Magnifying perfect lens with positive refraction

    CERN Document Server

    Tyc, Tomas

    2010-01-01

    We propose a device with a positive isotropic refractive index that creates a magnified perfect real image of an optically homogeneous three-dimensional region of space within geometrical optics. Its key ingredient is a new refractive index profile that can work as a perfect lens on its own, having a very moderate index range.

  1. Solar powered desalination system using Fresnel lens

    Science.gov (United States)

    Sales, M. T. B. F.

    2016-11-01

    The Philippines is surrounded by coastal areas and these areas can be a potential source for potable water. This study aims to design and construct a solar powered desalination system using Fresnel lens. The experimental study was conducted using polluted salt water for the sample and desalination was carried out using the designed system. The desalination system was composed of the solar concentrator, solar still and the condenser system. The Fresnel lens was made of acrylic plastic and was an effective solar concentrator. Solar stills made of dark colored glass bottles were effective in absorbing the solar energy. The condenser system made of polybutylene and polystyrene were effective in condensing the vapor at ambient temperature. The shortest time of vaporization of the salt water was at 293 sec and the optimum angle of position of the lens was 36.42°. The amount of condensate collected was directly proportional to the amount of salt water in the solar still. The highest mean efficiency of the designed set-up was 34.82%. The water produced by the solar powered desalination system using Fresnel lens passed the standards set by WHO (World Health Organization) for drinking water.

  2. Intraocular lens in a fighter aircraft pilot.

    OpenAIRE

    Loewenstein, A; Geyer, O; Biger, Y; Bracha, R; Shochat, I; Lazar, M.

    1991-01-01

    A pseudophakic pilot of the Israeli air force flying an F-15 (Eagle) aircraft was followed up for three years. He experienced about 100 flying hours, 5% of the time under high g stress. The intraocular lens did not dislocate and no complications were observed. It seems that flying high performance fighter aircraft is not contraindicated in pseudophakic pilots.

  3. High Accuracy Dual Lens Transmittance Measurements

    Science.gov (United States)

    2007-08-01

    measurement of lens transmission,” Metrologia 37, 603–605 (2000). 3. B. Munro, “Quantum information processing with light and its requirement for detectors...5. N. P. Fox, “Trap detectors and their properties,” Metrologia 28, 197–202 (1991). 5402 APPLIED OPTICS Vol. 46, No. 22 1 August 2007 6. S. L

  4. Label-free imaging and quantitative chemical analysis of Alzheimer's disease brain samples with multimodal multiphoton nonlinear optical microspectroscopy

    Science.gov (United States)

    Lee, Jang Hyuk; Kim, Dae Hwan; Song, Woo Keun; Oh, Myoung-Kyu; Ko, Do-Kyeong

    2015-05-01

    We developed multimodal multiphoton microspectroscopy using a small-diameter probe with gradient-index lenses and applied it to unstained Alzheimer's disease (AD) brain samples. Our system maintained the image quality and spatial resolution of images obtained using an objective lens of similar numerical aperture. Multicolor images of AD brain samples were obtained simultaneously by integrating two-photon excited fluorescence and second-harmonic generation on a coherent anti-Stokes Raman scattering (CARS) microendoscope platform. Measurements of two hippocampal regions, the cornus ammonis-1 and dentate gyrus, revealed more lipids, amyloid fibers, and collagen in the AD samples than in the normal samples. Normal and AD brains were clearly distinguished by a large spectral difference and quantitative analysis of the CH mode using CARS microendoscope spectroscopy. We expect this system to be an important diagnosis tool in AD research.

  5. High Dk piggyback contact lens system for contact lens-intolerant keratoconus patients

    OpenAIRE

    Tomris Sengor; Sevda Aydin Kurna; Suat Aki; et al

    2011-01-01

    Tomris Sengor, Sevda Aydin Kurna, Suat Aki, Yelda ÖzkurtFatih Sultan Mehmet Training and Research Hospital, Istanbul, TurkeyBackground: The aim of the study was to examine the clinical success of high Dk (oxygen permeability) piggyback contact lens (PBCL) systems for the correction of contact lens intolerant keratoconus patients.Methods: Sixteen patients (29 eyes) who were not able to wear gas-permeable rigid lenses were included in this study. Hyper Dk silicone hydrogel (oxygen tran...

  6. Minus Piggyback Lens Overlaying ReSTOR® Multifocal Lens in High Myopia

    Directory of Open Access Journals (Sweden)

    Isha Gupta

    2013-06-01

    Full Text Available Background: We report the case of a 40-year-old female patient treated with implantation of the Acrysof® IQ ReSTOR® lens (Alcon, Fort Worth, Tex., USA with overlaying Acrysof EXpand® minus piggyback lens (Alcon. Methods: The patient had high myopia and was diagnosed with presbyopia and bilateral posterior subcapsular cataract. She desired to be spectacle-free and opted to undergo bilateral placement of the ReSTOR multifocal lens. The necessary intraocular lens (IOL power was +3.5 in the right eye and +4.0 in the left eye, though the range of commercially available ReSTOR lenses is +6.0 to +34.0 D. In order to achieve emmetropia in this case of high myopia, it was determined that an EXpand minus piggyback lens would be necessary. Results: Implantation of the ReSTOR lens with overlaying EXpand minus piggyback lens was performed successfully and without complication. At 5 months postoperatively, the patient had 20/20 uncorrected visual acuity in both eyes. She reported a high level of satisfaction and was able to return to her daily activities including reading and driving without spectacles. Conclusion: We report successful primary implantation of AcrySof EXpand minus piggyback lenses overlying the AcrySof IQ ReSTOR lens in a patient with high myopia. Long-term follow-up and further evaluation is necessary to establish piggyback IOL implantation with multifocal IOL as an accepted treatment for high myopia with presbyopia.

  7. Preventive role of lens antioxidant defense mechanism against riboflavin-mediated sunlight damaging of lens crystallins.

    Science.gov (United States)

    Anbaraki, Afrooz; Khoshaman, Kazem; Ghasemi, Younes; Yousefi, Reza

    2016-10-01

    The main components of sunlight reaching the eye lens are UVA and visible light exerting their photo-damaging effects indirectly by the aid of endogenous photosensitizer molecules such as riboflavin (RF). In this study, lens proteins solutions were incubated with RF and exposed to the sunlight. Then, gel mobility shift analysis and different spectroscopic assessments were applied to examine the structural damaging effects of solar radiation on these proteins. Exposure of lens proteins to direct sunlight, in the presence of RF, leads to marked structural crosslinking, oligomerization and proteolytic instability. These structural damages were also accompanied with reduction in the emission fluorescence of Trp and Tyr and appearance of a new absorption peak between 300 and 400nm which can be related to formation of new chromophores. Also, photo-oxidation of lens crystallins increases their oligomeric size distribution as examined by dynamic light scattering analysis. The above mentioned structural insults, as potential sources of sunlight-induced senile cataract and blindness, were significantly attenuated in the presence of ascorbic acid and glutathione which are two important components of lens antioxidant defense system. Therefore, the powerful antioxidant defense mechanism of eye lens is an important barrier against molecular photo-damaging effects of solar radiations during the life span. Copyright © 2016 Elsevier B.V. All rights reserved.

  8. Fiber Optic Pressure Sensor using Multimode Interference

    Energy Technology Data Exchange (ETDEWEB)

    Ruiz-Perez, V I; Sanchez-Mondragon, J J [INAOE, Apartado Postal 51 y 216, Puebla 72000 (Mexico); Basurto-Pensado, M A [CIICAp, Universidad Autonoma del Estado de Morelos (Mexico); LiKamWa, P [CREOL, University of Central Florida, Orlando, FL 32816 (United States); May-Arrioja, D A, E-mail: iruiz@inaoep.mx, E-mail: mbasurto@uaem.mx, E-mail: delta_dirac@hotmail.com, E-mail: daniel_may_arrioja@hotmail.com [UAT Reynosa Rodhe, Universidad Autonoma de Tamaulipas (Mexico)

    2011-01-01

    Based on the theory of multimode interference (MMI) and self-image formation, we developed a novel intrinsic optical fiber pressure sensor. The sensing element consists of a section of multimode fiber (MMF) without cladding spliced between two single mode fibers (SMF). The MMI pressure sensor is based on the intensity changes that occur in the transmitted light when the effective refractive index of the MMF is changed. Basically, a thick layer of Polydimethylsiloxane (PDMS) is placed in direct contact with the MMF section, such that the contact area between the PDMS and the fiber will change proportionally with the applied pressure, which results in a variation of the transmitted light intensity. Using this configuration, a good correlation between the measured intensity variations and the applied pressure is obtained. The sensitivity of the sensor is 3 {mu}V/psi, for a range of 0-60 psi, and the maximum resolution of our system is 0.25 psi. Good repeatability is also observed with a standard deviation of 0.0019. The key feature of the proposed pressure sensor is its low fabrication cost, since the cost of the MMF is minimal.

  9. Multimodal brain monitoring in fulminant hepatic failure

    Institute of Scientific and Technical Information of China (English)

    Fernando; Mendes; Paschoal; Jr; Ricardo; Carvalho; Nogueira; Karla; De; Almeida; Lins; Ronconi; Marcelo; de; Lima; Oliveira; Manoel; Jacobsen; Teixeira; Edson; Bor-Seng-Shu

    2016-01-01

    Acute liver failure, also known as fulminant hepatic failure(FHF), embraces a spectrum of clinical entities characterized by acute liver injury, severe hepatocellular dysfunction, and hepatic encephalopathy. Cerebral edema and intracranial hypertension are common causes of mortality in patients with FHF. The management of patients who present acute liver failure starts with determining the cause and an initial evaluation of prognosis. Regardless of whether or not patients are listed for liver transplantation, they should still be monitored for recovery, death, or transplantation. In the past, neuromonitoring was restricted to serial clinical neurologic examination and, in some cases, intracranial pressure monitoring. Over the years, this monitoring has proven insufficient, as brain abnormalities were detected at late and irreversible stages. The need for real-time monitoring of brain functions to favor prompt treatment and avert irreversible brain injuries led to the concepts of multimodal monitoring and neurophysiological decision support. New monitoring techniques, such as brain tissue oxygen tension, continuous electroencephalogram, transcranial Doppler, and cerebral microdialysis, have been developed. These techniques enable early diagnosis of brain hemodynamic, electrical, and biochemical changes, allow brain anatomical and physiological monitoring-guided therapy, and have improved patient survival rates. The purpose of this review is to discuss the multimodality methods available for monitoring patients with FHF in the neurocritical care setting.

  10. Multimodal pain management after arthroscopic surgery

    DEFF Research Database (Denmark)

    Rasmussen, Sten

    Multimodal Pain Management after Arthroscopic Surgery By Sten Rasmussen, M.D. The thesis is based on four randomized controlled trials. The main hypothesis was that multimodal pain treatment provides faster recovery after arthroscopic surgery. NSAID was tested against placebo after knee arthrosco...... after knee and ankle arthroscopy with the use of oral NSAIDs combined with bupivacaine plus morphine or combined with bupivacaine, morphine plus steroid....... ankle arthroscopy. Oral NSAID reduced time to work from 17 to 14 days after knee arthroscopy. Intra-articular treatment with bupivacaine plus morphine and bupivacaine plus morphine plus steroid after arthroscopic knee meniscectomy reduced time to work from 10 to 5 to 3 days. Intraarticular treatment...... with bupivacaine plus morphine and bupivacaine plus morphine plus steroid after diagnostic knee arthroscopy reduced time to work from 10 to 5 to 2 days. Additional analysis revealed that the surgical trauma and the use of tourniquet influenced recovery. The thesis proves a reduction in the time to return to work...

  11. Multimodal Imaging in Hereditary Retinal Diseases

    Directory of Open Access Journals (Sweden)

    Francesco Pichi

    2013-01-01

    Full Text Available Introduction. In this retrospective study we evaluated the multimodal visualization of retinal genetic diseases to better understand their natural course. Material and Methods. We reviewed the charts of 70 consecutive patients with different genetic retinal pathologies who had previously undergone multimodal imaging analyses. Genomic DNA was extracted from peripheral blood and genotyped at the known locus for the different diseases. Results. The medical records of 3 families of a 4-generation pedigree affected by North Carolina macular dystrophy were reviewed. A total of 8 patients with Stargardt disease were evaluated for their two main defining clinical characteristics, yellow subretinal flecks and central atrophy. Nine male patients with a previous diagnosis of choroideremia and eleven female carriers were evaluated. Fourteen patients with Best vitelliform macular dystrophy and 6 family members with autosomal recessive bestrophinopathy were included. Seven patients with enhanced s-cone syndrome were ascertained. Lastly, we included 3 unrelated patients with fundus albipunctatus. Conclusions. In hereditary retinal diseases, clinical examination is often not sufficient for evaluating the patient’s condition. Retinal imaging then becomes important in making the diagnosis, in monitoring the progression of disease, and as a surrogate outcome measure of the efficacy of an intervention.

  12. Ten unanswered questions in multimodal communication.

    Science.gov (United States)

    Partan, Sarah R

    2013-01-01

    The study of multimodal communication has become an active and vibrant field. This special issue of Behavioral Ecology and Sociobiology brings together new developments in this rapidly expanding area. In this final contribution to the special issue, I look to the future and discuss ten questions in need of further work, touching on issues ranging from theoretical modeling and the evolution of behavior to molecular mechanisms and the development of behavior. In particular, I emphasize that the use of multimodal communication allows animals to switch between sensory channels when one channel becomes too noisy, and suggest that a better understanding of this process may help us both to understand the evolution of multisensory signaling and to predict the success of species facing environmental changes that affect signaling channels, such as urbanization and climate change. An expanded section is included on the effects of climate change on animal communication across sensory channels, urging researchers to pursue this topic due to the rapidity with which the environment is currently transforming.

  13. ANALYSING SPACE: ADAPTING AND EXTENDING MULTIMODAL SEMIOTICS

    Directory of Open Access Journals (Sweden)

    Louise J. Ravelli

    2015-07-01

    Full Text Available In the field of multimodal discourse analysis, one of the most exciting sites of application is that of 3D space: examining aspects of built environment for its meaningmaking potential. For the built environment – homes, offices, public buildings, parks, etc. – does indeed make meaning. These are spaces which speak – often their meanings are so familiar, we no longer hear what they say; sometimes, new and unusual sites draw attention to their meanings, and they are hotly contested. This chapter will suggest ways of analyzing 3D texts, based on the framework of Kress and van Leeuwen (2006. This framework, developed primarily for the analysis of 2D images, has been successfully extended to a range of other multimodal texts. Extension to the built environment includes Pang (2004, O’Toole (1994, Ravelli (2006, Safeyton (2004, Stenglin (2004 and White (1994, whose studies will inform the analyses presented here. This article will identify some of the key theoretical principles which underline this approach, including the notions of text, context and metafunction, and will describe some of the main areas of analysis for 3D texts. Also, ways of bringing the analyses together will be considered. The analyses will be demonstrated in relation to the Scientia building at the University of New South Wales, Australia.

  14. Multimodal brain monitoring in fulminant hepatic failure.

    Science.gov (United States)

    Paschoal, Fernando Mendes; Nogueira, Ricardo Carvalho; Ronconi, Karla De Almeida Lins; de Lima Oliveira, Marcelo; Teixeira, Manoel Jacobsen; Bor-Seng-Shu, Edson

    2016-08-01

    Acute liver failure, also known as fulminant hepatic failure (FHF), embraces a spectrum of clinical entities characterized by acute liver injury, severe hepatocellular dysfunction, and hepatic encephalopathy. Cerebral edema and intracranial hypertension are common causes of mortality in patients with FHF. The management of patients who present acute liver failure starts with determining the cause and an initial evaluation of prognosis. Regardless of whether or not patients are listed for liver transplantation, they should still be monitored for recovery, death, or transplantation. In the past, neuromonitoring was restricted to serial clinical neurologic examination and, in some cases, intracranial pressure monitoring. Over the years, this monitoring has proven insufficient, as brain abnormalities were detected at late and irreversible stages. The need for real-time monitoring of brain functions to favor prompt treatment and avert irreversible brain injuries led to the concepts of multimodal monitoring and neurophysiological decision support. New monitoring techniques, such as brain tissue oxygen tension, continuous electroencephalogram, transcranial Doppler, and cerebral microdialysis, have been developed. These techniques enable early diagnosis of brain hemodynamic, electrical, and biochemical changes, allow brain anatomical and physiological monitoring-guided therapy, and have improved patient survival rates. The purpose of this review is to discuss the multimodality methods available for monitoring patients with FHF in the neurocritical care setting.

  15. Multimodal Network Equilibrium with Stochastic Travel Times

    Directory of Open Access Journals (Sweden)

    M. Meng

    2014-01-01

    Full Text Available The private car, unlike public traffic modes (e.g., subway, trolley running along dedicated track-ways, is invariably subject to various uncertainties resulting in travel time variation. A multimodal network equilibrium model is formulated that explicitly considers stochastic link capacity variability in the road network. The travel time of combined-mode trips is accumulated based on the concept of the mean excess travel time (METT which is a summation of estimated buffer time and tardy time. The problem is characterized by an equivalent VI (variational inequality formulation where the mode choice is expressed in a hierarchical logit structure. Specifically, the supernetwork theory and expansion technique are used herein to represent the multimodal transportation network, which completely represents the combined-mode trips as constituting multiple modes within a trip. The method of successive weighted average is adopted for problem solutions. The model and solution method are further applied to study the trip distribution and METT variations caused by the different levels of the road conditions. Results of numerical examples show that travelers prefer to choose the combined travel mode as road capacity decreases. Travelers with different attitudes towards risk are shown to exhibit significant differences when making travel choice decisions.

  16. A multimodal behavioral approach to performance anxiety.

    Science.gov (United States)

    Lazarus, Arnold A; Abramovitz, Arnold

    2004-08-01

    Cognitive-behavior therapy (CBT) stresses a trimodal assessment framework (affect, behavior, and cognition [ABC]), whereas the multimodal approach assesses seven discrete but interactive components--behavior, affect, sensation, imagery, cognition, interpersonal relationships, and drugs/biological factors (BASIC I.D.). Only complex or recalcitrant cases call for the entire seven-pronged range of multimodal interventions. Various case illustrations are offered as examples of how a clinician might proceed when confronted with problems that fall under the general heading of performance anxiety. The main example is of a violinist in a symphony orchestra whose career was in serious jeopardy because of his extreme fear of performing in public. He responded very well to a focused but elaborate desensitization procedure. The hierarchy that was eventually constructed contained many dimensions and subhierarchies featuring interlocking elements that evoked his anxiety. In addition to imaginal systematic desensitization, sessions were devoted to his actual performance in the clinical setting. As a homework assignment, he found it helpful to listen to a long-playing record of an actual rehearsal and to play along with the world-renowned orchestra and conductor. The subsequent disclosure by the client of an important sexual problem was dealt with concomitantly by using a fairly conventional counseling procedure. Therapy required 20 sessions over a 3-month period.

  17. Photonic lantern with multimode fibers embedded

    Science.gov (United States)

    Yu, Hai-Jiao; Yan, Qi; Huang, Zong-Jun; Tian, He; Jiang, Yu; Liu, Yong-Jun; Zhang, Jian-Zhong; Sun, Wei-Min

    2014-08-01

    A photonic lantern is studied which is formed by seven multimode fibers inserted into a pure silica capillary tube. The core of the tapered end has a uniform refractive index because the polymer claddings are removed before the fibers are inserted. Consequently, the light distribution is also uniform. Two theories describing a slowly varying waveguide and multimode coupling are used to analyze the photonic lantern. The transmission loss decreases as the length of the tapered part increases. For a device with a taper length of 3.4 cm, the loss is about 1.06 dB on average for light propagating through the taper from an inserted fiber to the tapered end and 0.99 dB in the reverse direction. For a device with a taper length of 0.7 cm, the two loss values are 2.63 dB and 2.53 dB, respectively. The results show that it is possible to achieve a uniform light distribution with the tapered end and a low-loss transmission in the device if parameters related to the lantern are reasonably defined.

  18. Liquid bridge as a tunable-focus cylindrical liquid lens

    Science.gov (United States)

    Chen, H.; Tabatabaei, N.; Amirfazli, A.

    2017-01-01

    We proposed a method to create a tunable-focus cylindrical liquid lens using a liquid bridge between two narrow surfaces. Due to the surface edge effect, the interface of the liquid bridge (on the long side) was shown to be able to serve as a tunable-focus cylindrical liquid lens. The working distance of the lens can be adjusted by changing either or both of the height of the bridge (H) and the volume of the liquid (V). By varying H and V, the lens can serve as either diverging or converging lens, with a minimum working distance of 2.11 mm.

  19. Gram negative bacteria and contact lens induced acute red eye

    Directory of Open Access Journals (Sweden)

    Sankaridurg Padmaja

    1996-01-01

    Full Text Available Two patients using hydrogel contact lenses on a daily wear schedule slept overnight with the lenses and woke up with a Contact Lens Induced Acute Red Eye (CLARE. The contact lenses recovered aseptically at the time of the event grew significant colonies of Pseudomonas aeruginosa and Aeromonas hydrophila in patient A and Pseudomonas aeruginosa and Serratia liquefaciens from patient B. Similar organisams from the contact lenses were recovered from the lens case and lens care solutions of patient B. In both the patients the condition resolved on discontinuation of lens wear. Patient compliance as a requirement for successful contact lens wear is highlighted with the illustration of these cases.

  20. Acid phosphatase and lipid peroxidation in human cataractous lens epithelium

    Directory of Open Access Journals (Sweden)

    Vasavada Abhay

    1993-01-01

    Full Text Available The anterior lens epithelial cells undergo a variety of degenerative and proliferative changes during cataract formation. Acid phosphatase is primarily responsible for tissue regeneration and tissue repair. The lipid hydroperoxides that are obtained by lipid peroxidation of polysaturated or unsaturated fatty acids bring about deterioration of biological membranes at cellular and tissue levels. Acid phosphatase and lipid peroxidation activities were studied on the lens epithelial cells of nuclear cataract, posterior subcapsular cataract, mature cataract, and mixed cataract. Of these, mature cataractous lens epithelium showed maximum activity for acid phosphatase (516.83 moles of p-nitrophenol released/g lens epithelium and maximum levels of lipid peroxidation (86.29 O.D./min/g lens epithelium. In contrast, mixed cataractous lens epithelium showed minimum activity of acid phosphatase (222.61 moles of p-nitrophenol released/g lens epithelium and minimum levels of lipid peroxidation (54.23 O.D./min/g lens epithelium. From our study, we correlated the maximum activity of acid phosphatase in mature cataractous lens epithelium with the increased areas of superimposed cells associated with the formation of mature cataract. Likewise, the maximum levels of lipid peroxidation in mature cataractous lens epithelium was correlated with increased permeability of the plasma membrane. Conversely, the minimum levels of lipid peroxidation in mixed cataractous lens epithelium makes us presume that factors other than lipid peroxidation may also account for the formation of mixed type of cataract.

  1. Performance Evaluation of Multimodal Multifeature Authentication System Using KNN Classification

    Directory of Open Access Journals (Sweden)

    Gayathri Rajagopal

    2015-01-01

    Full Text Available This research proposes a multimodal multifeature biometric system for human recognition using two traits, that is, palmprint and iris. The purpose of this research is to analyse integration of multimodal and multifeature biometric system using feature level fusion to achieve better performance. The main aim of the proposed system is to increase the recognition accuracy using feature level fusion. The features at the feature level fusion are raw biometric data which contains rich information when compared to decision and matching score level fusion. Hence information fused at the feature level is expected to obtain improved recognition accuracy. However, information fused at feature level has the problem of curse in dimensionality; here PCA (principal component analysis is used to diminish the dimensionality of the feature sets as they are high dimensional. The proposed multimodal results were compared with other multimodal and monomodal approaches. Out of these comparisons, the multimodal multifeature palmprint iris fusion offers significant improvements in the accuracy of the suggested multimodal biometric system. The proposed algorithm is tested using created virtual multimodal database using UPOL iris database and PolyU palmprint database.

  2. Performance evaluation of similarity measures for dense multimodal stereovision

    Science.gov (United States)

    Yaman, Mustafa; Kalkan, Sinan

    2016-05-01

    Multimodal imaging systems have recently been drawing attention in fields such as medical imaging, remote sensing, and video surveillance systems. In such systems, estimating depth has become possible due to the promising progress of multimodal matching techniques. We perform a systematic performance evaluation of similarity measures frequently used in the literature for dense multimodal stereovision. The evaluated measures include mutual information (MI), sum of squared distances, normalized cross-correlation, census transform, local self-similarity (LSS) as well as descriptors adopted to multimodal settings, like scale invariant feature transform (SIFT), speeded-up robust features (SURF), histogram of oriented gradients (HOG), binary robust independent elementary features, and fast retina keypoint (FREAK). We evaluate the measures over datasets we generated, compiled, and provided as a benchmark and compare the performances using the Winner Takes All method. The datasets are (1) synthetically modified four popular pairs from the Middlebury Stereo Dataset (namely, Tsukuba, Venus, Cones, and Teddy) and (2) our own multimodal image pairs acquired using the infrared and the electro-optical cameras of a Kinect device. The results show that MI and HOG provide promising results for multimodal imagery, and FREAK, SURF, SIFT, and LSS can be considered as alternatives depending on the multimodality level and the computational complexity requirements of the intended application.

  3. Towards an intelligent framework for multimodal affective data analysis.

    Science.gov (United States)

    Poria, Soujanya; Cambria, Erik; Hussain, Amir; Huang, Guang-Bin

    2015-03-01

    An increasingly large amount of multimodal content is posted on social media websites such as YouTube and Facebook everyday. In order to cope with the growth of such so much multimodal data, there is an urgent need to develop an intelligent multi-modal analysis framework that can effectively extract information from multiple modalities. In this paper, we propose a novel multimodal information extraction agent, which infers and aggregates the semantic and affective information associated with user-generated multimodal data in contexts such as e-learning, e-health, automatic video content tagging and human-computer interaction. In particular, the developed intelligent agent adopts an ensemble feature extraction approach by exploiting the joint use of tri-modal (text, audio and video) features to enhance the multimodal information extraction process. In preliminary experiments using the eNTERFACE dataset, our proposed multi-modal system is shown to achieve an accuracy of 87.95%, outperforming the best state-of-the-art system by more than 10%, or in relative terms, a 56% reduction in error rate.

  4. Multimodal Task-Driven Dictionary Learning for Image Classification.

    Science.gov (United States)

    Bahrampour, Soheil; Nasrabadi, Nasser M; Ray, Asok; Jenkins, William Kenneth

    2016-01-01

    Dictionary learning algorithms have been successfully used for both reconstructive and discriminative tasks, where an input signal is represented with a sparse linear combination of dictionary atoms. While these methods are mostly developed for single-modality scenarios, recent studies have demonstrated the advantages of feature-level fusion based on the joint sparse representation of the multimodal inputs. In this paper, we propose a multimodal task-driven dictionary learning algorithm under the joint sparsity constraint (prior) to enforce collaborations among multiple homogeneous/heterogeneous sources of information. In this task-driven formulation, the multimodal dictionaries are learned simultaneously with their corresponding classifiers. The resulting multimodal dictionaries can generate discriminative latent features (sparse codes) from the data that are optimized for a given task such as binary or multiclass classification. Moreover, we present an extension of the proposed formulation using a mixed joint and independent sparsity prior, which facilitates more flexible fusion of the modalities at feature level. The efficacy of the proposed algorithms for multimodal classification is illustrated on four different applications--multimodal face recognition, multi-view face recognition, multi-view action recognition, and multimodal biometric recognition. It is also shown that, compared with the counterpart reconstructive-based dictionary learning algorithms, the task-driven formulations are more computationally efficient in the sense that they can be equipped with more compact dictionaries and still achieve superior performance.

  5. Hypoplastic basement membrane of the lens anlage in the inheritable lens aplastic mouse (lap mouse).

    Science.gov (United States)

    Aso, S; Baba, R; Noda, S; Ikuno, S; Fujita, M

    2000-04-01

    Adult homozygous lap mice show various eye abnormalities such as aphakia, retinal disorganization, and dysplasia of the cornea and anterior chamber. In the fetal eye of a homozygous lap mouse, the lens placode appears to develop normally. However, the lens vesicle develops abnormally to form a mass of cells without a cavity, and the mass vanishes soon afterward. Apoptotic cell death is associated with the disappearance of the lens anlage. We examined the basement membranes of the lens anlage of this mutant by immunohistochemical methods under light microscopy using antibodies against basement membrane components of the lens anlage, type IV collagen, fibronectin, laminin, heparan sulfate proteoglycan, and entactin and by transmission electron microscopy. Immunohistochemistry showed the distribution and intensity of antibody binding to the lens anlage to be almost the same for each these antibodies regardless of the stage of gestation or whether the anlagen were from normal BALB/c or lap mice. Thus, positive continuous reactions were observed around the exterior region of the lens anlage from day 10 of gestation for type IV collagen, fibronectin, laminin, heparan sulfate proteoglycan antibodies, and at least from day 11of gestation for entactin antibody. The basement membrane lamina densa of both normal and lap mice was shown by electron microscopy to be discontinuous at days 10 and 10.5 of gestation. However, by day 11 the lamina densa was continuous in the lens anlagen of normal mice but still discontinuous in the lap mice. By day 12 of gestation, the lamina densa had thickened markedly in normal mice, whereas in lap mice it remained discontinuous and its thinness indicated hypoplasia. These results indicate that, while all basement components examined are produced and deposited in the normal region of the lens anlage in the lap mouse, the basement membrane is, for some reason, imperfectly formed. The time at which hypoplasia of the basement membrane was observed

  6. Lightweight autoclavable wide-angle contact lens for vitreous surgery.

    Science.gov (United States)

    Chalam, K V; Gupta, Shailesh K; Agarwal, Swati

    2007-01-01

    The authors describe an autoclavable, self-stabilizing, lightweight wide-angle contact lens for vitrectomy. The lens has two optical pieces with perforated plastic casing to sustain a high temperature (150 degrees C) for autoclaving. The lens has a 106 degrees static and 127 degrees dynamic field of view. The footplates and reduced weight (2.4 grams) due to the plastic casing allow self-stabilization of the lens. The open lens design.with high temperature resistant plastic prevents fogging during autoclaving and surgery. The autoclavable, self-stabilizing, lightweight wide-angle contact lens allows visualization of the peripheral retina during surgery and faster sterilization by autoclaving between surgeries without the disadvantage of lens fogging.

  7. Method and apparatus for sputtering with a plasma lens

    Energy Technology Data Exchange (ETDEWEB)

    Anders, Andre

    2016-09-27

    A plasma lens for enhancing the quality and rate of sputter deposition onto a substrate is described herein. The plasma lens serves to focus positively charged ions onto the substrate while deflecting negatively charged ions, while at the same time due to the line of sight positioning of the lens, allowing for free passage of neutrals from the target to the substrate. The lens itself is formed of a wound coil of multiple turns, inside of which are deposed spaced lens electrodes which are electrically paired to impress an E field overtop the B field generated by the coil, the potential applied to the electrodes increasing from end to end towards the center of the lens, where the applied voltage is set to a high potential at the center electrodes as to produce a potential minimum on the axis of the lens.

  8. Pars Plana Vitrectomy in Treatment of Lens Injury

    Directory of Open Access Journals (Sweden)

    Remzi Avcı

    2013-01-01

    Full Text Available Lens injury due to traumas may present as loss of capsule integrity, cataract, lens subluxation, or lens luxation. In addition, lens subluxation and lens luxation may occur in pseudophakic patients due to trauma. Clear corneal, scleral or sclero-corneal phacoemulsification surgery, pars plana vitrectomy, pars plana vitrectomy with phaco-fragmentation, or pars plana vitrectomy with removal through corneal incision techniques are used in the treatment of lens injury due to traumas. Intraocular lens can be implanted in the bag, sulcus, or anterior chamber during the surgery. Depending on the circumstances, scleral fixated intraocular lenses or iris-claw lenses may also be preferred. Rehabilitation of such patients is not of a great concern today, with the advanced level of vitreoretinal surgery and cataract surgery techniques and with the current state of technology. (Turk J Ophthalmol 2013; 43: 51-4

  9. System and Method for Null-Lens Wavefront Sensing

    Science.gov (United States)

    Hill, Peter C. (Inventor); Thompson, Patrick L. (Inventor); Aronstein, David L. (Inventor); Bolcar, Matthew R. (Inventor); Smith, Jeffrey S. (Inventor)

    2015-01-01

    A method of measuring aberrations in a null-lens including assembly and alignment aberrations. The null-lens may be used for measuring aberrations in an aspheric optic with the null-lens. Light propagates from the aspheric optic location through the null-lens, while sweeping a detector through the null-lens focal plane. Image data being is collected at locations about said focal plane. Light is simulated propagating to the collection locations for each collected image. Null-lens aberrations may extracted, e.g., applying image-based wavefront-sensing to collected images and simulation results. The null-lens aberrations improve accuracy in measuring aspheric optic aberrations.

  10. Development of a micromirror-scanned multimodal CARS miniaturized microscope for the in vivo study of spinal cord disorders

    Science.gov (United States)

    Murugkar, Sangeeta; Smith, Brett; Naji, Majid; Brideau, Craig; Stys, Peter; Anis, Hanan

    2011-03-01

    We discuss the design and implementation of a novel multimodal coherent anti-Stokes Raman scattering (CARS) miniaturized microscope for imaging of injured and recovering spinal cords in a single living animal. We demonstrate for the first time, the use of a biaxial microelectromechanical system (MEMS) mirror for scanning and diffraction limited multiple lens miniaturized objective for exciting a CARS signal. The miniaturized microscope design includes light delivery using a large mode area photonic crystal fiber (PCF), and multimode fiber for collection of the nonlinear optical signal. The basic design concept, major engineering challenges, solutions, and preliminary results are presented. We demonstrate CARS and two photon excitation fluorescence microscopy in a benchtop setup with the miniaturized optics and MEMS scanning. The light source is based on a single femtosecond laser (pump beam) and a supercontinuum generated in a nonlinear PCF (Stokes beam). This is coupled using free space optics onto the surface of a resonantly driven two dimensional scanning MEMS mirror that scans the excitation light in a Lissajous pattern. The novel design of the miniaturized microscope is expected to provide significant new information on the pathogenesis of demyelinating diseases such as Multiple Sclerosis and Spinal Cord Injury.

  11. Ex vivo catheter-based imaging of coronary atherosclerosis using multimodality OCT and NIRAF excited at 633 nm

    Science.gov (United States)

    Wang, Hao; Gardecki, Joseph A.; Ughi, Giovanni J.; Jacques, Paulino Vacas; Hamidi, Ehsan; Tearney, Guillermo J.

    2015-01-01

    While optical coherence tomography (OCT) has been shown to be capable of imaging coronary plaque microstructure, additional chemical/molecular information may be needed in order to determine which lesions are at risk of causing an acute coronary event. In this study, we used a recently developed imaging system and double-clad fiber (DCF) catheter capable of simultaneously acquiring both OCT and red excited near-infrared autofluorescence (NIRAF) images (excitation: 633 nm, emission: 680nm to 900nm). We found that NIRAF is elevated in lesions that contain necrotic core – a feature that is critical for vulnerable plaque diagnosis and that is not readily discriminated by OCT alone. We first utilized a DCF ball lens probe and a bench top setup to acquire en face NIRAF images of aortic plaques ex vivo (n = 20). In addition, we used the OCT-NIRAF system and fully assembled catheters to acquire multimodality images from human coronary arteries (n = 15) prosected from human cadaver hearts (n = 5). Comparison of these images with corresponding histology demonstrated that necrotic core plaques exhibited significantly higher NIRAF intensity than other plaque types. These results suggest that multimodality intracoronary OCT-NIRAF imaging technology may be used in the future to provide improved characterization of coronary artery disease in human patients. PMID:25909020

  12. Aberrations of the point spread function of a multimode fiber

    CERN Document Server

    Descloux, Adrien; Pinkse, Pepijn W H

    2016-01-01

    We investigate the point spread function of a multimode fiber. The distortion of the focal spot created on the fiber output facet is studied for a variety of the parameters. We develop a theoretical model of wavefront shaping through a multimode fiber and use it to confirm our experimental results and analyze the nature of the focal distortions. We show that aberration-free imaging with a large field of view can be achieved by using an appropriate number of segments on the spatial light modulator during the wavefront-shaping procedure. The results describe aberration limits for imaging with multimode fibers as in, e.g., microendoscopy.

  13. Multimodal approaches to use mobile, digital devices in learning practies

    DEFF Research Database (Denmark)

    Buhl, Mie

    In this paper, I discuss the potential of multimodal approaches to enhance learning processes. I draw on a case based on Danish Master Courses in ICT and didactic designs where multimodal approaches are in the center of students’ practical design experience as well as in generation of theoretical...... framework draws on recent currents in the field of multimodality and learning, visual culture pedagogy, ict and didactic designs, art and aesthetics....... that support and facilitate the processes of transforming experiences into theoretical knowledge. I argue that this didactic concept enhances a sensitive cognition based on rationality as described by the philosopher Baumgarten (1750). Furthermore, I argue that the emergence of mobile digital devices...

  14. In vivo multimodal nonlinear optical imaging of mucosal tissue

    Science.gov (United States)

    Sun, Ju; Shilagard, Tuya; Bell, Brent; Motamedi, Massoud; Vargas, Gracie

    2004-05-01

    We present a multimodal nonlinear imaging approach to elucidate microstructures and spectroscopic features of oral mucosa and submucosa in vivo. The hamster buccal pouch was imaged using 3-D high resolution multiphoton and second harmonic generation microscopy. The multimodal imaging approach enables colocalization and differentiation of prominent known spectroscopic and structural features such as keratin, epithelial cells, and submucosal collagen at various depths in tissue. Visualization of cellular morphology and epithelial thickness are in excellent agreement with histological observations. These results suggest that multimodal nonlinear optical microscopy can be an effective tool for studying the physiology and pathology of mucosal tissue.

  15. Multi-modality molecular imaging for gastric cancer research

    Science.gov (United States)

    Liang, Jimin; Chen, Xueli; Liu, Junting; Hu, Hao; Qu, Xiaochao; Wang, Fu; Nie, Yongzhan

    2011-12-01

    Because of the ability of integrating the strengths of different modalities and providing fully integrated information, multi-modality molecular imaging techniques provide an excellent solution to detecting and diagnosing earlier cancer, which remains difficult to achieve by using the existing techniques. In this paper, we present an overview of our research efforts on the development of the optical imaging-centric multi-modality molecular imaging platform, including the development of the imaging system, reconstruction algorithms and preclinical biomedical applications. Primary biomedical results show that the developed optical imaging-centric multi-modality molecular imaging platform may provide great potential in the preclinical biomedical applications and future clinical translation.

  16. Investigation on a compact in-line multimode-single-mode-multimode fiber structure

    Science.gov (United States)

    Yin, Bin; Li, Yang; Liu, Zhi-bo; Feng, Suchun; Bai, Yunlong; Xu, Yao; Jian, Shuisheng

    2016-06-01

    We carried out a detailed investigation on a compact in-line multimode single-mode multimode (MSM) fiber structure. Both theoretical modal and experimental setup were established to demonstrate the transmission characteristics and the corresponding responses of the applied strain and temperature. The proposed structure simply involves a section of the single-mode fiber (SMF) spliced to two sections of multimode fiber (MMF) and lead-in and lead-out SMFs. The excited environment-sensitive cladding modes together with the fundamental mode in the central SMF form a typical Mach-Zehnder interferometer (MZI). We analyzed the transmission characteristics of the different length of the middle SMF and the MMF in detail. In the experiment, we obtained the extinction ratio of the MSM fiber structure based MZI comb spectrum which was up to 20 dB, and sensitivities of 0.7096 pm/με (0-2000 με) and 44.12 pm/°C (10-70 °C), which proved the potential sensing applications of the proposed fiber structure.

  17. Motion-free hybrid design laser beam propagation analyzer using a digital micromirror device and a variable focus liquid lens.

    Science.gov (United States)

    Sheikh, Mumtaz; Riza, Nabeel A

    2010-06-01

    To the best of our knowledge, we propose the first motion-free laser beam propagation analyzer with a hybrid design using a digital micromirror device (DMD) and a liquid electronically controlled variable focus lens (ECVFL). Unlike prior analyzers that require profiling the beam at multiple locations along the light propagation axis, the proposed analyzer profiles the beam at the same plane for multiple values of the ECVFL focal length, thus eliminating beam profiler assembly motion. In addition to measuring standard Gaussian beam parameters, the analyzer can also be used to measure the M(2) beam propagation parameter of a multimode beam. Proof-of-concept beam parameter measurements with the proposed analyzer are successfully conducted for a 633 nm laser beam. Given the all-digital nature of the DMD-based profiling and all-analog motion-free nature of the ECVFL beam focus control, the proposed analyzer versus prior art promises better repeatability, speed, and reliability.

  18. A polycarbonate ophthalmic-prescription lens series.

    Science.gov (United States)

    Davis, J K

    1978-08-01

    Improvements in polycarbonate material, production techniques, and scratch-resistant coatings, combined with a process-oriented design, have resulted in a precision lens series. Surface quality is comparable to that of untreated glass ophthalmic lenses. The repeatability of the process results in closely controlled axial power and off-axis performance. For most lens prescriptions, the ANSI Z80.1 optical-center specifications for prescription accuracy are maintained through a total field of view of 40 deg for an 8-mm range of center-of-rotation distances. Off-axis astigmatism is controlled for near-point seeing. The lenses are both lighter and thinner than those of crown glass. A scratch-resistant coating reduces the reflections normally associated with high-index (1.586) materials. Impact resistance exceeds that required by ANSI Z80.7 and is many times that required by ANSI Z80.1.

  19. A Tribute to Dr. Willy Lens

    Directory of Open Access Journals (Sweden)

    Maarten Vansteenkiste

    2016-07-01

    Full Text Available Dr. Willy Lens, born on December 10th, 1943, passed away on August 29th, 2014. With his passing, the motivation community has lost a seminal member, a mentor, and a friend. Dr. Lens – a Fellow of the Association for Psychological Science and Founding Fellow of the American Educational Research Association – made fundamental contributions to the study of motivation both through his own work and through his caring and thoughtful mentorship of a large community of scholars. With this tribute, we want to honor Dr. Willy Lens’ significance to psychology and education as well as his positive influence, both personally and professionally, on the lives of dozens of scholars. With his contagious enthusiasm and caring mentorship, Willy was an example for our academic community and with this tribute we express our gratitude for the privilege to have collaborated with him.

  20. Understanding Science Through the Computational Lens

    Institute of Scientific and Technical Information of China (English)

    Richard M. Karp

    2011-01-01

    This article explores the changing nature of the interaction between computer science and the natural and social sciences.After briefly tracing the history of scientific computation,the article presents the concept of computational lens,a metaphor for a new relationship that is emerging between the world of computation and the world of the sciences.Our main thesis is that,in many scientific fields,the processes being studied can be viewed as computational in nature,in the sense that the processes perform dynamic transformations on information represented as digital data.Viewing natural or engineered systems through the lens of their computational requirements or capabilities provides new insights and ways of thinking.A number of examples are discussed in support of this thesis.The examples are from various fields,including quantum computing,statistical physics,the World Wide Web and the Internet,mathematics,and computational molecular biology.

  1. Hyperbolic metamaterial lens with hydrodynamic nonlocal response.

    Science.gov (United States)

    Yan, Wei; Mortensen, N Asger; Wubs, Martijn

    2013-06-17

    We investigate the effects of hydrodynamic nonlocal response in hyperbolic metamaterials (HMMs), focusing on the experimentally realizable parameter regime where unit cells are much smaller than an optical wavelength but much larger than the wavelengths of the longitudinal pressure waves of the free-electron plasma in the metal constituents. We derive the nonlocal corrections to the effective material parameters analytically, and illustrate the noticeable nonlocal effects on the dispersion curves numerically. As an application, we find that the focusing characteristics of a HMM lens in the local-response approximation and in the hydrodynamic Drude model can differ considerably. In particular, the optimal frequency for imaging in the nonlocal theory is blueshifted with respect to that in the local theory. Thus, to detect whether nonlocal response is at work in a hyperbolic metamaterial, we propose to measure the near-field distribution of a hyperbolic metamaterial lens.

  2. A Lens Mapping Algorithm for Weak Lensing

    CERN Document Server

    Saini, T D; Saini, Tarun Deep; Raychaudhury, Somak

    2001-01-01

    We develop an algorithm for the reconstruction of the two-dimensional massdistribution of a cluster of galaxies from the observable distortion ofbackground galaxies. From the measured reduced shear gamma_i/(1-kappa) the lensmapping is directly obtained, from which a mass distribution is derived. Thisis unlike other methods where the convergence (kappa) is first obtained. Weshow that this method works best for sub-critical lenses but can be applied toa critical lens away from the critical lines. For finite fields the usualmass-sheet degeneracy is shown to exist in this method as well. We suggest aniterative scheme to remove the mass-sheet degeneracy for the case of asub-critical lens, in the absence of a substantial external shear. The sametechnique can be used with additional information for the case of a criticallens as well. A scheme to reduce the effects of noise is also suggested.

  3. Multimodal interfaces with voice and gesture input

    Energy Technology Data Exchange (ETDEWEB)

    Milota, A.D.; Blattner, M.M.

    1995-07-20

    The modalities of speech and gesture have different strengths and weaknesses, but combined they create synergy where each modality corrects the weaknesses of the other. We believe that a multimodal system such a one interwining speech and gesture must start from a different foundation than ones which are based solely on pen input. In order to provide a basis for the design of a speech and gesture system, we have examined the research in other disciplines such as anthropology and linguistics. The result of this investigation was a taxonomy that gave us material for the incorporation of gestures whose meanings are largely transparent to the users. This study describes the taxonomy and gives examples of applications to pen input systems.

  4. Entanglement frustration in multimode Gaussian states

    CERN Document Server

    Lupo, Cosmo; Facchi, Paolo; Florio, Giuseppe; Pascazio, Saverio

    2011-01-01

    Bipartite entanglement between two parties of a composite quantum system can be quantified in terms of the purity of one party and there always exists a pure state of the total system that maximizes it (and minimizes purity). When many different bipartitions are considered, the requirement that purity be minimal for all bipartitions gives rise to the phenomenon of entanglement frustration. This feature, observed in quantum systems with both discrete and continuous variables, can be studied by means of a suitable cost function whose minimizers are the maximally multipartite-entangled states (MMES). In this paper we extend the analysis of multipartite entanglement frustration of Gaussian states in multimode bosonic systems. We derive bounds on the frustration, under the constraint of finite mean energy, in the low and high energy limit.

  5. Anatomy and efficiency of urban multimodal mobility

    CERN Document Server

    Gallotti, Riccardo

    2014-01-01

    The growth of transportation networks and their increasing interconnections, although positive, has the downside effect of an increasing complexity which make them difficult to use, to assess, and limits their efficiency. On average in the UK, 23% of travel time is lost in connections for trips with more than one mode, and the lack of synchronization decreases very slowly with population size. This lack of synchronization between modes induces differences between the theoretical quickest trip and the `time-respecting' path, which takes into account waiting times at interconnection nodes. We analyse here the statistics of these paths on the multilayer, temporal network of the entire, multimodal british public transportation system. We propose a statistical decomposition -- the `anatomy' -- of trips in urban areas, in terms of riding, waiting and walking times, and which shows how the temporal structure of trips varies with distance and allows us to compare different cities. Weaknesses in systems can be either ...

  6. Multimodal Evolution Approach to Multidimensional Intrusion Detection

    Institute of Scientific and Technical Information of China (English)

    Weng Guang'an; Yu Shengsheng; Zhou Jingli

    2006-01-01

    An artificial immunity based multimodal evolution algorithm is developed to generate detectors with variable coverage for multidimensional intrusion detection. In this algorithm, a proper fitness function is used to drive the detectors to fill in those detection holes close to self set or among self spheres, and genetic algorithm is adopted to reduce the negative effects that different distribution of self imposes on the detector generating process. The validity of the algorithm is tested with spherical and rectangular detectors,respectively, and experiments performed on two real data sets ( machine learning database and DAPRA99) indicate that the proposed algorithm can obtain good results on spherical detectors, and that its performances in detection rate, false alarm rate, stability, time cost, and adaptability to incomplete training set on spherical detectors are all better than on rectangular ones.

  7. Compressive multi-mode superresolution display

    KAUST Repository

    Heide, Felix

    2014-01-01

    Compressive displays are an emerging technology exploring the co-design of new optical device configurations and compressive computation. Previously, research has shown how to improve the dynamic range of displays and facilitate high-quality light field or glasses-free 3D image synthesis. In this paper, we introduce a new multi-mode compressive display architecture that supports switching between 3D and high dynamic range (HDR) modes as well as a new super-resolution mode. The proposed hardware consists of readily-available components and is driven by a novel splitting algorithm that computes the pixel states from a target high-resolution image. In effect, the display pixels present a compressed representation of the target image that is perceived as a single, high resolution image. © 2014 Optical Society of America.

  8. Photon correlations in multi-mode waveguides

    CERN Document Server

    Poem, Eilon; 10.1103/PhysRevA.84.041805

    2012-01-01

    We consider the propagation of classical and non-classical light in multi-mode optical waveguides. We focus on the evolution of the few-photon correlation functions, which, much like the light-intensity distribution in such systems, evolve in a periodic manner, culminating in the 'revival' of the initial correlation pattern at the end of each period. It is found that when the input state possesses non trivial symmetries, the correlation revival period can be longer than that of the intensity, and thus the same intensity pattern can display different correlation patterns. We experimentally demonstrate this effect for classical, pseudo-thermal light, and compare the results with the predictions for non-classical, quantum light.

  9. Adesivos universais ou multi-mode

    OpenAIRE

    Tavares, Ana Sofia Peixe

    2016-01-01

    Os adesivos Universais (SAU) ou Multi-mode são dispositivos recentemente lançados no mercado que visam oferecer ao Médico Dentista a livre escolha da estratégia de adesão (ER e SE) a usar consoante o tipo de condição clínica. Estes adesivos são categorizados como Universais por serem versáteis quanto ás suas instruções de uso e áreas de aplicação. Na realidade, os SAU são uma extensão melhorada e adaptada, dos adesivos SE. O presente trabalho consiste numa revisão narrativa sob...

  10. Multimode bolometer development for the PIXIE instrument

    CERN Document Server

    Nagler, Peter C; Denis, Kevin L; Devasia, Archana M; Fixsen, Dale J; Kogut, Alan J; Manos, George; Porter, Scott; Stevenson, Thomas R

    2016-01-01

    The Primordial Inflation Explorer (PIXIE) is an Explorer-class mission concept designed to measure the polarization and absolute intensity of the cosmic microwave background. In the following, we report on the design, fabrication, and performance of the multimode polarization-sensitive bolometers for PIXIE, which are based on silicon thermistors. In particular we focus on several recent advances in the detector design, including the implementation of a scheme to greatly raise the frequencies of the internal vibrational modes of the large-area, low-mass optical absorber structure consisting of a grid of micromachined, ion-implanted silicon wires. With $\\sim30$ times the absorbing area of the spider-web bolometers used by Planck, the tensioning scheme enables the PIXIE bolometers to be robust in the vibrational and acoustic environment at launch of the space mission. More generally, it could be used to reduce microphonic sensitivity in other types of low temperature detectors. We also report on the performance ...

  11. Multimodality imaging of structure and function

    Energy Technology Data Exchange (ETDEWEB)

    Townsend, D W [Departments of Medicine and Radiology, University of Tennessee Medical Center, 1924 Alcoa Highway, Knoxville, TN 37920 (United States)], E-mail: dtownsend@mc.utmck.edu

    2008-02-21

    Historically, medical devices to image either anatomical structure or functional processes have developed along somewhat independent paths. The recognition that combining images from different modalities can nevertheless offer significant diagnostic advantages gave rise to sophisticated software techniques to coregister structure and function. Recently, alternatives to retrospective software-based fusion have become available through instrumentation that combines two imaging modalities within a single device, an approach that has since been termed hardware fusion. As a result, following their recent introduction into the clinic, combined PET/CT and SPECT/CT devices are now playing an increasingly important role in the diagnosis and staging of human disease. Recently, although limited to the brain, the first clinical MR scanner with a PET insert, a technically-challenging design, has been undergoing evaluation. This review will follow the development of multimodality instrumentation for clinical use from conception to present-day technology and assess the status and future potential for such devices. (topical review)

  12. Multimode directionality in all-dielectric metasurfaces

    CERN Document Server

    Yang, Yuanqing; Kostinski, Sarah V; Odit, Mikhail; Kapitanova, Polina; Qiu, Min; Kivshar, Yuri

    2016-01-01

    All-dielectric resonant nanophotonics has emerged recently as a new direction of research aiming at the manipulation of strong optically-induced electric and magnetic Mie resonances in dielectric nanoparticles with high refractive index, for a design of metadevices with reduced dissipative losses and large resonant enhancement of both electric and magnetic fields. Usually, the geometry of dielectric nanoparticles is considered to be close to either sphere or rod, so the exact Mie solutions of the scattering problem are applied. Here we study nanoparticles with a large aspect ratio (such as nanobars) and describe a novel type of hybrid Mie-Fabry-Perot modes responsible for the existence of multiple magnetic dipole resonances. The multiple magnetic dipoles originate from a combination of a magnetic dipolar mode and a number of standing waves of an elongated anisotropic nanobar. We reveal that these novel hybrid modes can interfere constructively with the induced electric dipoles and thereby lead to multimode un...

  13. Hearables: Multimodal physiological in-ear sensing

    CERN Document Server

    Goverdovsky, Valentin; Nakamura, Takashi; Looney, David; Sharp, David J; Papavassiliou, Christos; Morrell, Mary J; Mandic, Danilo P

    2016-01-01

    Future health systems require the means to assess and track the neural and physiological function of a user over long periods of time and in the community. Human body responses are manifested through multiple modalities, such as the mechanical, electrical and chemical; yet current physiological monitors (actigraphy, heart rate) largely lack in both the desired cross-modal and non-stigmatizing aspects. We address these challenges through an inconspicuous and comfortable earpiece, equipped with miniature multimodal sensors, which benefits from the relatively stable position of the ear canal with respect to vital organs to robustly measure the brain, cardiac and respiratory functions. Comprehensive experiments validate each modality within the proposed earpiece, while its potential in health monitoring is illustrated through case studies. We further demonstrate how combining data from multiple sensors within such an integrated wearable device improves both the accuracy of measurements and the ability to deal wit...

  14. Azimut: a multimodal locomotion robotic platform

    Science.gov (United States)

    Michaud, Francois; Letourneau, Dominic; Arsenault, Martin; Bergeron, Yann; Cadrin, Richard; Gagnon, Frederic; Legault, Marc-Antoine; Millette, Mathieu; Pare, Jean-Francois; Tremblay, Marie-Christine; Lepage, Pierre; Morin, Yan; Caron, Serge

    2003-09-01

    Other than from its sensing and processing capabilities, a mobile robotic platform can be limited in its use by its ability to move in the environment. A wheeled robot works well on flat surfaces. Tracks are useful over rough terrains, while legs allow a robot to move over obstacles. In this paper we present a new concept of mobile robot with the objective of combining different locomotion mechanisms on the same platform to increase its locomotion capabilities. After presenting a review of multi-modal robotic platforms, we describe the design of our robot called AZIMUT. AZIMUT combines wheels, legs and tracks to move in three-dimensional environments. The robot is symmetrical and is made of four independent leg-track-wheel articulations. It can move with its articulations up, down or straight, or move sideways without changing the robot's orientation. The robot could be used in surveillance and rescue missions, exploration or operation in hazardous environments.

  15. Investigating multimodal communication in virtual meetings

    DEFF Research Database (Denmark)

    Persson, John Stouby; Mathiassen, Lars

    2014-01-01

    propositions that explain how interrelating of verbal and visual acts based on shared dynamic representations enable communication repairs during virtual meetings. We argue the proposed framework provides researchers with a novel and practical approach to investigate the complex data involved in virtual......To manage distributed work, organizations increasingly rely on virtual meetings based on multimodal, synchronous communication technologies. However, despite technological advances, it is still challenging to coordinate knowledge through these meetings with spatial and cultural separation. Against...... recordings of their oral exchanges and video recordings of their shared dynamic representation of the project’s status and plans, our analysis reveals how their interrelating of visual and verbal communication acts enabled effective communication and coordination. In conclusion, we offer theoretical...

  16. Automatic processing of multimodal tomography datasets.

    Science.gov (United States)

    Parsons, Aaron D; Price, Stephen W T; Wadeson, Nicola; Basham, Mark; Beale, Andrew M; Ashton, Alun W; Mosselmans, J Frederick W; Quinn, Paul D

    2017-01-01

    With the development of fourth-generation high-brightness synchrotrons on the horizon, the already large volume of data that will be collected on imaging and mapping beamlines is set to increase by orders of magnitude. As such, an easy and accessible way of dealing with such large datasets as quickly as possible is required in order to be able to address the core scientific problems during the experimental data collection. Savu is an accessible and flexible big data processing framework that is able to deal with both the variety and the volume of data of multimodal and multidimensional scientific datasets output such as those from chemical tomography experiments on the I18 microfocus scanning beamline at Diamond Light Source.

  17. Managing hyperemesis gravidarum: a multimodal challenge

    Directory of Open Access Journals (Sweden)

    Mylonas I

    2010-07-01

    Full Text Available Abstract Up to 90% of pregnant women experience nausea and vomiting. When prolonged or severe, this is known as hyperemesis gravidarum (HG, which can, in individual cases, be life threatening. In this article the aetiology, diagnosis and treatment strategies will be presented based on a selective literature review. Treatment strategies range from outpatient dietary advice and antiemetic drugs to hospitalization and intravenous (IV fluid replacement in persistent or severe cases. Alternative methods, such as acupuncture, are not yet evidence based but sometimes have a therapeutic effect. In most cases, the condition is self limiting and subsides by around 20 weeks gestation. More severe forms require medical intervention once other organic causes of nausea and vomiting have been excluded. In addition, a psychosomatic approach is often helpful. In view of its potential complexity, general practitioners and obstetricians should be well informed about HG and therapy should be multimodal.

  18. Multimodal event streams for virtual reality

    Science.gov (United States)

    von Spiczak, J.; Samset, E.; DiMaio, S.; Reitmayr, G.; Schmalstieg, D.; Burghart, C.; Kikinis, R.

    2007-01-01

    Applications in the fields of virtual and augmented reality as well as image-guided medical applications make use of a wide variety of hardware devices. Existing frameworks for interconnecting low-level devices and high-level application programs do not exploit the full potential for processing events coming from arbitrary sources and are not easily generalizable. In this paper, we will introduce a new multi-modal event processing methodology using dynamically-typed event attributes for event passing between multiple devices and systems. The existing OpenTracker framework was modified to incorporate a highly flexible and extensible event model, which can store data that is dynamically created and arbitrarily typed at runtime. The main factors impacting the library's throughput were determined and the performance was shown to be sufficient for most typical applications. Several sample applications were developed to take advantage of the new dynamic event model provided by the library, thereby demonstrating its flexibility and expressive power.

  19. Testing Two Tools for Multimodal Navigation

    Directory of Open Access Journals (Sweden)

    Mats Liljedahl

    2012-01-01

    Full Text Available The latest smartphones with GPS, electronic compasses, directional audio, touch screens, and so forth, hold a potential for location-based services that are easier to use and that let users focus on their activities and the environment around them. Rather than interpreting maps, users can search for information by pointing in a direction and database queries can be created from GPS location and compass data. Users can also get guidance to locations through point and sweep gestures, spatial sound, and simple graphics. This paper describes two studies testing two applications with multimodal user interfaces for navigation and information retrieval. The applications allow users to search for information and get navigation support using combinations of point and sweep gestures, nonspeech audio, graphics, and text. Tests show that users appreciated both applications for their ease of use and for allowing users to interact directly with the surrounding environment.

  20. Managing hyperemesis gravidarum: a multimodal challenge.

    Science.gov (United States)

    Jueckstock, J K; Kaestner, R; Mylonas, I

    2010-07-15

    Up to 90% of pregnant women experience nausea and vomiting. When prolonged or severe, this is known as hyperemesis gravidarum (HG), which can, in individual cases, be life threatening. In this article the aetiology, diagnosis and treatment strategies will be presented based on a selective literature review. Treatment strategies range from outpatient dietary advice and antiemetic drugs to hospitalization and intravenous (IV) fluid replacement in persistent or severe cases. Alternative methods, such as acupuncture, are not yet evidence based but sometimes have a therapeutic effect.In most cases, the condition is self limiting and subsides by around 20 weeks gestation. More severe forms require medical intervention once other organic causes of nausea and vomiting have been excluded. In addition, a psychosomatic approach is often helpful.In view of its potential complexity, general practitioners and obstetricians should be well informed about HG and therapy should be multimodal.

  1. Multimodal Indexing of Multilingual News Video

    Directory of Open Access Journals (Sweden)

    Hiranmay Ghosh

    2010-01-01

    Full Text Available The problems associated with automatic analysis of news telecasts are more severe in a country like India, where there are many national and regional language channels, besides English. In this paper, we present a framework for multimodal analysis of multilingual news telecasts, which can be augmented with tools and techniques for specific news analytics tasks. Further, we focus on a set of techniques for automatic indexing of the news stories based on keywords spotted in speech as well as on the visuals of contemporary and domain interest. English keywords are derived from RSS feed and converted to Indian language equivalents for detection in speech and on ticker texts. Restricting the keyword list to a manageable number results in drastic improvement in indexing performance. We present illustrative examples and detailed experimental results to substantiate our claim.

  2. Condensation of Thresholds in Multimode Microlasers

    CERN Document Server

    Ge, Li; Stone, A Douglas

    2016-01-01

    We show from ab initio laser theory that by choosing an appropriate spatial pump profile, many different spatial modes of a typical microlaser can be turned on at the same pump energy, substantially increasing the number, N, of simultaneous lasing modes. The optimal pump profile can be obtained simply from knowledge of the space-dependent saturated gain profile when the system is uniformly pumped up to the Nth modal threshold. We test this general result by applying it to a two-dimensional diffusive random laser and a microdisk laser. Achieving highly multimode lasing at reasonable pump powers is useful for reducing the spatial coherence of laser sources, making them suitable for use in speckle-free imaging and other applications.

  3. Fibrosis in the lens. Sprouty regulation of TGFβ-signaling prevents lens EMT leading to cataract.

    Science.gov (United States)

    Lovicu, F J; Shin, E H; McAvoy, J W

    2016-01-01

    Cataract is a common age-related condition that is caused by progressive clouding of the normally clear lens. Cataract can be effectively treated by surgery; however, like any surgery, there can be complications and the development of a secondary cataract, known as posterior capsule opacification (PCO), is the most common. PCO is caused by aberrant growth of lens epithelial cells that are left behind in the capsular bag after surgical removal of the fiber mass. An epithelial-to-mesenchymal transition (EMT) is central to fibrotic PCO and forms of fibrotic cataract, including anterior/posterior polar cataracts. Transforming growth factor β (TGFβ) has been shown to induce lens EMT and consequently research has focused on identifying ways of blocking its action. Intriguingly, recent studies in animal models have shown that EMT and cataract developed when a class of negative-feedback regulators, Sprouty (Spry)1 and Spry2, were conditionally deleted from the lens. Members of the Spry family act as general antagonists of the receptor tyrosine kinase (RTK)-mediated MAPK signaling pathway that is involved in many physiological and developmental processes. As the ERK/MAPK signaling pathway is a well established target of Spry proteins, and overexpression of Spry can block aberrant TGFβ-Smad signaling responsible for EMT and anterior subcapsular cataract, this indicates a role for the ERK/MAPK pathway in TGFβ-induced EMT. Given this and other supporting evidence, a case is made for focusing on RTK antagonists, such as Spry, for cataract prevention. In addition, and looking to the future, this review also looks at possibilities for supplanting EMT with normal fiber differentiation and thereby promoting lens regenerative processes after cataract surgery. Whilst it is now known that the epithelial to fiber differentiation process is driven by FGF, little is known about factors that coordinate the precise assembly of fibers into a functional lens. However, recent research

  4. A stereoscopic lens for digital cinema cameras

    Science.gov (United States)

    Lipton, Lenny; Rupkalvis, John

    2015-03-01

    Live-action stereoscopic feature films are, for the most part, produced using a costly post-production process to convert planar cinematography into stereo-pair images and are only occasionally shot stereoscopically using bulky dual-cameras that are adaptations of the Ramsdell rig. The stereoscopic lens design described here might very well encourage more live-action image capture because it uses standard digital cinema cameras and workflow to save time and money.

  5. Gravitational Lens: Deep Space Probe Design

    Science.gov (United States)

    2012-03-01

    List of Abbreviations Abbreviation Page FSM Focal Space Mission . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 CMB Cosmic Microwave...concert with the sun’s gravitational lens to image nearby solar systems and/or other pertinent astronomical objects, e.g. the Cosmic Microwave Background...CMB) radiation. 1.2 Thesis Objective In Deep Space Flight and Communications Claudio Maccone uses the mass, radius , mean density, and Schwarzschild

  6. Rose-K contact lens for keratoconus

    Directory of Open Access Journals (Sweden)

    Jain Arun

    2007-01-01

    Full Text Available Aim: To report clinical experience and the comparative value of axial and instantaneous topography data in fitting Rose-K design contact lenses in moderate and severe keratoconus. Materials and Methods: Thirty-eight eyes (of 23 patients with keratoconus were fitted with Rose-K design contact lenses and followed up for at least six months or more. Visual acuity with habitual vision correction available was measured. Axial and instantaneous topography maps for each eye were recorded. Contact lens wear comfort was graded on a ten point rating scale every three months. Results: Fourteen (100% moderate keratoconus eyes (average Sim K 48.61 ± 1.24D and 23 of 24 (96% of severe keratoconus eyes (average Sim K 60.88 ± 5.31D were successfully fitted with the Rose-K lenses. Final fit contact lenses in severe keratoconus had statistically significant steeper base curves compared to average axial corneal curvature than in moderate keratoconus eyes. Average simulated corneal curvature on axial maps predicted final fit contact lens base curves significantly better than on instantaneous maps. Thirty-three of the 37 eyes fitted with contact lenses maintained wear comfort over average follow up period of 13 ± 3.5 months. Conclusions: Rose-K design rigid contact lenses are successful in visually rehabilitating 100% of moderate and 96% of severe keratoconus eyes. Most patients (90% maintained contact lens wear comfort. Corneal curvature on axial maps is a better predictive of base curve of final fit contact lens.

  7. INFORMATION SUPPORT TRANSPORTATION PROCESS MULTIMODAL SYSTEM

    Directory of Open Access Journals (Sweden)

    N. A. Filippova

    2015-02-01

    Full Text Available Background: is to improve information support for the organization and functioning of multimodal systems delive-ry modes of transport in the northern regions of the Russian Federation on the basis of the development of theoretical and methodological and practical provisions, criteria, methods and mathematical models.Method or methodology of the work: a methodology placement vehicle logistics center (TLC in the Nordic region, providing links all transport modes involved in the delivery of energy, developed a model to optimize the parameters of the transport network, used for traffic, the most effective schemes of delivery of goods in multimodal report, taking into account the specifics of the Nordic region, and funding.Results: Studies have applied and may be used by the fe-deral and regional authorities and management in the deve-lopment of integrated programs for energy-Northern regions. Proposed in the theoretical research and methodological approaches are one way to increase the efficiency of the delivery of goods in the event of a little predictable situations on the route, TLC and transhipment points. The developed techniques are used and can be used to improve the northern region of the process control of cargo delivery.Conclusion: Therefore, based on the analysis of the status of the issue, it is quite obvious that the very topical area of optimization of the transport needs of the region to ensure the development and implementation of methods to improve the efficiency and quality of freight traffic by improving organizational structures and technology traffic control all transport space in the region.

  8. Comparison and Calibration of Mobile Phone Fisheye Lens and Regular Fisheye Lens via Equidistant Model

    Directory of Open Access Journals (Sweden)

    Cumhur Sahin

    2016-01-01

    Full Text Available Nowadays, mobile phones are more than a device that can only satisfy the communication need between people. In addition to providing ease to human lives with various applications, lens kits that can be integrated to mobile phones have recently been introduced. Fisheye lenses that are compliant with mobile phones are one of these new types of equipment. Since fisheye lenses integrated with mobile phones are lightweight and easy to use, they are advantageous. In addition to this advantage, whether fisheye lens and mobile phone combination can be used in a photogrammetric way is experimented, and if so, what will be the result. The main purpose of this study is to test fisheye lens equipment used with mobile phones. In this study, standard calibration of “Olloclip 3 in one” fisheye lens used with iPhone 4S mobile phone and “Nikon FC-E9” fisheye lens used with Nikon Coolpix8700 are compared based on equidistant model. The results of these calibrations are analyzed, using photogrammetric bundle block adjustment. This study suggests a precalibration process of these kinds of hardware for the photogrammetric process in the test field.

  9. Effects of Different Contact Lens Designs on Visual Quality Among the Soft Spherical Contact Lens Users

    Directory of Open Access Journals (Sweden)

    Mustafa Demir

    2013-10-01

    Full Text Available Purpose: To evaluate the effects of different lens designs on visual quality among soft spherical contact lens users. Material and Method: Forty eyes of twenty patients from our contact lens unit were included in this study. Refractive errors of the patients were between -0.50 and -6.0 diopters with 0.05. Total higher order aberration mean rms value was 0.29±0.10 µm without glasses, while it was 0.33±0.10 µm with Balafilcon A lenses and 0.31±0.10 µm with Senofilcon A lenses. Higher order aberration values measured after contact lens application did not show a significant difference for two contact lens designs (p>0.05. Discussion: High and low contrast sensitivity values were better with spectacles compared to contact lenses. We did not observe significant difference in higher order aberration values and visual quality between aspheric and spheric designed lenses. (Turk J Ophthalmol 2013; 43: 321-5

  10. Three rare diseases in one Sib pair: RAI1, PCK1, GRIN2B mutations associated with Smith-Magenis Syndrome, cytosolic PEPCK deficiency and NMDA receptor glutamate insensitivity.

    Science.gov (United States)

    Adams, David R; Yuan, Hongjie; Holyoak, Todd; Arajs, Katrina H; Hakimi, Parvin; Markello, Thomas C; Wolfe, Lynne A; Vilboux, Thierry; Burton, Barbara K; Fajardo, Karin Fuentes; Grahame, George; Holloman, Conisha; Sincan, Murat; Smith, Ann C M; Wells, Gordon A; Huang, Yan; Vega, Hugo; Snyder, James P; Golas, Gretchen A; Tifft, Cynthia J; Boerkoel, Cornelius F; Hanson, Richard W; Traynelis, Stephen F; Kerr, Douglas S; Gahl, William A

    2014-11-01

    The National Institutes of Health Undiagnosed Diseases Program evaluates patients for whom no diagnosis has been discovered despite a comprehensive diagnostic workup. Failure to diagnose a condition may arise from the mutation of genes previously unassociated with disease. However, we hypothesized that this could also co-occur with multiple genetic disorders. Demonstrating a complex syndrome caused by multiple disorders, we report two siblings manifesting both similar and disparate signs and symptoms. They shared a history of episodes of hypoglycemia and lactic acidosis, but had differing exam findings and developmental courses. Clinical acumen and exome sequencing combined with biochemical and functional studies identified three genetic conditions. One sibling had Smith-Magenis Syndrome and a nonsense mutation in the RAI1 gene. The second sibling had a de novo mutation in GRIN2B, which resulted in markedly reduced glutamate potency of the encoded receptor. Both siblings had a protein-destabilizing homozygous mutation in PCK1, which encodes the cytosolic isoform of phosphoenolpyruvate carboxykinase (PEPCK-C). In summary, we present the first clinically-characterized mutation of PCK1 and demonstrate that complex medical disorders can represent the co-occurrence of multiple diseases.

  11. Review of small aspheric glass lens molding technologies

    Science.gov (United States)

    Yin, Shaohui; Jia, Hongpeng; Zhang, Guanhua; Chen, Fengjun; Zhu, Kejun

    2017-01-01

    Aspheric lens can eliminate spherical aberrations, coma, astigmatism, field distortions, and other adverse factors. This type of lens can also reduce the loss of light energy and obtain high-quality images and optical characteristics. The demand for aspheric lens has increased in recent years because of its advantageous use in the electronics industry, particularly for compact, portable devices and high-performance products. As an advanced manufacturing technology, the glass lens molding process has been recognized as a low-cost and high-efficiency manufacturing technology for machining small-diameter aspheric lens for industrial production. However, the residual stress and profile deviation of the glass lens are greatly affected by various key technologies for glass lens molding, including glass and mold-die material forming, mold-die machining, and lens molding. These key technical factors, which affect the quality of the glass lens molding process, are systematically discussed and reviewed to solve the existing technical bottlenecks and problems, as well as to predict the potential applicability of glass lens molding in the future.

  12. Rho GTPase inactivation impairs lens growth and integrity.

    Science.gov (United States)

    Rao, Vasantha; Wawrousek, Eric; Tamm, Ernst R; Zigler, Samuel

    2002-02-01

    To elucidate the significance of Rho GTPase signaling on lens growth and structural integrity, we have selectively inactivated Rho GTPase in the ocular lens. To achieve this tissue-specific inactivation, a transgene encoding the C3-exoenzyme from Clostridium botulinum has been expressed in mice under transcriptional control of the lens-specific alphaA-crystallin promoter. C3-exoenzyme is known to selectively inactivate all Rho GTPase isoforms by ADP-ribosylating an asparagine residue at position 41. Mice expressing the C3-exoenzyme transgene exhibited selective ocular defects, including cataract and microphthalmia. Extralenticular effects included ocular hemorrhage (blood accumulation in the anterior and posterior chambers of the eye) and abnormalities of the iris including focal attachments to lens and cornea (synechiae). C3-transgene expression was found only in the lens and not in the other ocular tissues as determined by RT-PCR analysis. Histologic examination of the eyes of C3 transgenic mice from two independent lines revealed extensive abnormalities of the lens, including defective fiber cell differentiation and elongation, ruptured posterior lens capsule, and thickened anterior lens capsule. Electron microscopic analysis of hemorrhaged C3 eyes showed abnormalities in the posterior hyaloid vessels. Collectively these data reveal the importance of Rho GTPase signaling in regulating lens growth and maintenance of lens transparency.

  13. Radiation dose to the eye lens

    DEFF Research Database (Denmark)

    Baun, Christina; Falch Braas, Kirsten; D. Nielsen, Kamilla

    2015-01-01

    might avoid including the eye in the CT scan without losing sufficient visualization of the scull base. The aim of this study was to evaluate the possibility of decreasing the radiation dose to the eye lens, simply by changing the head position, when doing the PET/CT scan from the base of the scull......Radiation Dose to the Eye Lens: Does Positioning Really Matter? C. Baun1, K. Falch1, K.D. Nielsen2, S. Shanmuganathan1, O. Gerke1, P.F. Høilund-Carlsen1 1Department of Nuclear Medicine, Odense University Hospital, Odense C, Denmark. 2University College Lillebaelt, Odense, Denmark. Aim: The scan...... field in oncology patients undergoing eyes-to-thighs PET/CT must always include the base of the scull according to department guidelines. The eye lens is sensitive to radiation exposure and if possible it should be avoided to scan the eye. If the patient’s head is kipped backwards during the scan one...

  14. Adaptive Liquid Lens Actuated by Droplet Movement

    Directory of Open Access Journals (Sweden)

    Chao Liu

    2014-08-01

    Full Text Available In this paper we report an adaptive liquid lens actuated by droplet movement. Four rectangular PMMA (Polymethyl Methacrylate substrates are stacked to form the device structure. Two ITO (Indium Tin Oxide sheets stick on the bottom substrate. One PMMA sheet with a light hole is inserted in the middle of the device. A conductive droplet is placed on the substrate and touches the PMMA sheet to form a small closed reservoir. The reservoir is filled with another immiscible non-conductive liquid. The non-conductive liquid can form a smooth concave interface with the light hole. When the device is applied with voltage, the droplet stretches towards the reservoir. The volume of the reservoir reduces, changing the curvature of the interface. The device can thus achieve the function of an adaptive lens. Our experiments show that the focal length can be varied from −10 to −159 mm as the applied voltage changes from 0 to 65 V. The response time of the liquid lens is ~75 ms. The proposed device has potential applications in many fields such as information displays, imaging systems, and laser scanning systems.

  15. Achromobacter xylosoxidans keratitis after contact lens usage.

    Science.gov (United States)

    Park, Jung Hyun; Song, Nang Hee; Koh, Jae Woong

    2012-02-01

    To report on Achromobacter xylosoxidans keratitis in two healthy patients who had worn contact lenses foran extended period of time. A 36-year-old female and a 21-year-old female visited our hospital with ocular pain and blurred vision. Both patients had a history of wearing soft contact lenses for over fve years with occasional overnight wear. At the initial presentation, a slit lamp examination revealed corneal stromal infiltrations and epithelial defects with peripheral neovascularization in both patients. Microbiological examinations were performed from samples of corneal scrapings, contact lenses, contact lens cases, and solution. The culture resulting from the samples taken from the contact lenses, contact lens cases, and solution were all positive for Achromobacter xylosoxidans. Confrming that the direct cause of the keratitis was the contact lenses, the frst patient was prescribed ceftazidime and amikacin drops sensitive to Achromobacter xylosoxidans. The second patient was treated with 0.3% gatifoxacin and fortifed tobramycin drops. After treatment, the corneal epithelial defects were completely healed, and subepithelial corneal opacity was observed. Two cases of Achromobacter xylosoxidans keratitis were reported in healthy young females who wore soft contact lenses. Achromobacter xylosoxidans should be considered a rare but potentially harmful pathogen for lens-induced keratitis in healthy hosts.

  16. CYLINDER LENS ALIGNMENT IN THE LTP

    Energy Technology Data Exchange (ETDEWEB)

    TAKACS, P.Z.

    2005-07-26

    The Long Trace Profiler (LTP), is well-suited for the measurement of the axial figure of cylindrical mirrors that usually have a long radius of curvature in the axial direction but have a short radius of curvature in the sagittal direction. The sagittal curvature causes the probe beam to diverge in the transverse direction without coming to a focus on the detector, resulting in a very weak signal. It is useful to place a cylinder lens into the optical system above the mirror under test to refocus the sagittal divergence and increase the signal level. A positive cylinder lens can be placed at two positions above the surface: the Cat's Eye reflection position and the Wavefront-Matching position. The Cat's Eye position, is very tolerant to mirror misalignment, which is not good if absolute axial radius of curvature is to be measured. Lateral positioning and rotational misalignments of lens and the mirror combine to produce unusual profile results. This paper looks at various alignment issues with measurements and by raytrace simulations to determine the best strategy to minimize radius of curvature errors in the measurement of cylindrical aspheres.

  17. CMB lens sample covariance and consistency relations

    Science.gov (United States)

    Motloch, Pavel; Hu, Wayne; Benoit-Lévy, Aurélien

    2017-02-01

    Gravitational lensing information from the two and higher point statistics of the cosmic microwave background (CMB) temperature and polarization fields are intrinsically correlated because they are lensed by the same realization of structure between last scattering and observation. Using an analytic model for lens sample covariance, we show that there is one mode, separately measurable in the lensed CMB power spectra and lensing reconstruction, that carries most of this correlation. Once these measurements become lens sample variance dominated, this mode should provide a useful consistency check between the observables that is largely free of sampling and cosmological parameter errors. Violations of consistency could indicate systematic errors in the data and lens reconstruction or new physics at last scattering, any of which could bias cosmological inferences and delensing for gravitational waves. A second mode provides a weaker consistency check for a spatially flat universe. Our analysis isolates the additional information supplied by lensing in a model-independent manner but is also useful for understanding and forecasting CMB cosmological parameter errors in the extended Λ cold dark matter parameter space of dark energy, curvature, and massive neutrinos. We introduce and test a simple but accurate forecasting technique for this purpose that neither double counts lensing information nor neglects lensing in the observables.

  18. Retina projection using curved lens arrays

    Science.gov (United States)

    Yen, Hao-Ren; Su, Guo-Dung J.

    2016-09-01

    In this paper, we propose a multi-channel imaging system which combines the principles of an insect's compound eye and optical cluster eye. The system consists of two curved structure lens arrays with different pitches. Both of them have the same curvature and the radiuses of the lenses in the arrays are optimized to focus rays on the retina. The optical axes of different channels are tilted to each other in order to reduce the optical system volume and transmit a wide field of view. Each channel of an array of multiple optical system transfers only a part of the field of view. Each partial image passes through each channel and stitches together on the retina to reconstruct a complete image. In order to simulate the image stitching, we also build an eye model. The thickness from the panel to the last surface of lens group is less than 25mm. The panel size is designed to be 4 inch which is the scale of eyeglass. The system can provide a large field of view about 150 degrees which is much wider than the commercial products. By using the 3D printer, we can make a model of lens array to achieve our design.

  19. Pitfalls in aphakic contact lens fitting

    Directory of Open Access Journals (Sweden)

    Dada Vijay

    1990-01-01

    Full Text Available We examined 23 consecutive cases of unilateral aphakia reporting to the contact lens office for endothelial count and morphology, corneal thickness and toricity. The fellow eye served as a control in all the cases. It was found that there is a significant drop in the central endothelial cell density, and change in the size and shape of the cells. These observations indicate a thermodynamically unstable state. The aphakic corneas were thicker than the controls but not to a significant extent. The cell count and pachymetry had no statistical correlation. Toricity of the aphakic corneas make successful fitting of a lens difficult. Since prolonged use of extended wear gas permeable as well as hydrogel lenses have a deleterious effect on the endothelium it is suggested that a careful case selection be made and strict monitoting carried out at follow up. These corneas are liable for decompensation with only mild noxious stimuli. This article is intended to acquaint the ophthalmologist with the pitfalls in aphakic contact lens fitting so that a cautious follow up may be planned.

  20. Radiation dose to the eye lens

    DEFF Research Database (Denmark)

    Baun, Christina; Falch Braas, Kirsten; D. Nielsen, Kamilla

    2015-01-01

    .69 – 4.46). With the high dose protocol and position ‘kipped’, the radiation dose to the eye lens decreased by 41.5%, on average by 1.52 mSv (95% CI: 0.39-2.64; p=0.008) compared to ‘standard’, i.e., from 3.66 mSv (range 1.62 – 4.68) to 2.14 mSv (range 1.12 – 4.46). With the low dose protocol......Radiation Dose to the Eye Lens: Does Positioning Really Matter? C. Baun1, K. Falch1, K.D. Nielsen2, S. Shanmuganathan1, O. Gerke1, P.F. Høilund-Carlsen1 1Department of Nuclear Medicine, Odense University Hospital, Odense C, Denmark. 2University College Lillebaelt, Odense, Denmark. Aim: The scan...... might avoid including the eye in the CT scan without losing sufficient visualization of the scull base. The aim of this study was to evaluate the possibility of decreasing the radiation dose to the eye lens, simply by changing the head position, when doing the PET/CT scan from the base of the scull...