WorldWideScience

Sample records for greatest vessel accuracy

  1. Efficient Vessel Tracking  with Accuracy Guarantees

    DEFF Research Database (Denmark)

    Redoutey, Martin; Scotti, Eric; Jensen, Christian Søndergaard

    2008-01-01

    Safety and security are top concerns in maritime navigation, particularly as maritime traffic continues to grow and as crew sizes are reduced. The Automatic Identification System (AIS) plays a key role in regard to these concerns. This system, whose objective is in part to identify and locate ves...... accuracies at lower communication costs. The techniques employ movement predictions that are shared between vessels and the VTS. Empirical studies with a prototype implementation and real vessel data demonstrate that the techniques are capable of significantly improving the AIS....

  2. Contrast-enhanced three-dimensional MR angiography of neck vessels: does dephasing effect alter diagnostic accuracy?

    International Nuclear Information System (INIS)

    Cosottini, M.; Calabrese, R.; Murri, L.; Puglioli, M.; Zampa, V.; Michelassi, M.C.; Ortori, S.; Bartolozzi, C.

    2003-01-01

    The aim of this study was to evaluate diagnostic accuracy of contrast-enhanced MRA (CEMRA) compared with digital subtraction angiography (DSA) in studying neck vessels of 48 patients. In three groups of patients, we used three MRA protocols differing for voxel size to assess if intravoxel dephasing effects could modify accuracy of CEMRA. Accuracy and correlation with DSA results were calculated in all patients and separately in the three groups. A qualitative analysis of the likeness between morphology of the stenosis in CEMRA and DSA images was also assessed. In all patients accuracy and agreement with DSA were 96% and k=0.85 in subclavian arteries, 96% and k=0.84 in vertebral artery, 97% and k=0.88 in common carotid arteries, and 94% and k=0.86 in internal carotid arteries. In the three groups accuracy and agreement with DSA did not show any significant difference. Qualitative analysis of CEMRA and DSA images revealed a better agreement in depicting the morphology of stenosis using a smaller voxel size. The CEMRA represents a powerful tool for the non-invasive evaluation of neck vessels. Overestimation trend of CEMRA is confirmed and the reduction of voxel size, decreasing the dephasing intravoxel effect, allows to have a better overlapping of stenosis morphology on CEMRA compared with DSA, but it does not yield diagnostic gain in the stenosis grading. (orig.)

  3. A 2D driven 3D vessel segmentation algorithm for 3D digital subtraction angiography data

    International Nuclear Information System (INIS)

    Spiegel, M; Hornegger, J; Redel, T; Struffert, T; Doerfler, A

    2011-01-01

    Cerebrovascular disease is among the leading causes of death in western industrial nations. 3D rotational angiography delivers indispensable information on vessel morphology and pathology. Physicians make use of this to analyze vessel geometry in detail, i.e. vessel diameters, location and size of aneurysms, to come up with a clinical decision. 3D segmentation is a crucial step in this pipeline. Although a lot of different methods are available nowadays, all of them lack a method to validate the results for the individual patient. Therefore, we propose a novel 2D digital subtraction angiography (DSA)-driven 3D vessel segmentation and validation framework. 2D DSA projections are clinically considered as gold standard when it comes to measurements of vessel diameter or the neck size of aneurysms. An ellipsoid vessel model is applied to deliver the initial 3D segmentation. To assess the accuracy of the 3D vessel segmentation, its forward projections are iteratively overlaid with the corresponding 2D DSA projections. Local vessel discrepancies are modeled by a global 2D/3D optimization function to adjust the 3D vessel segmentation toward the 2D vessel contours. Our framework has been evaluated on phantom data as well as on ten patient datasets. Three 2D DSA projections from varying viewing angles have been used for each dataset. The novel 2D driven 3D vessel segmentation approach shows superior results against state-of-the-art segmentations like region growing, i.e. an improvement of 7.2% points in precision and 5.8% points for the Dice coefficient. This method opens up future clinical applications requiring the greatest vessel accuracy, e.g. computational fluid dynamic modeling.

  4. Automated method for identification and artery-venous classification of vessel trees in retinal vessel networks.

    Science.gov (United States)

    Joshi, Vinayak S; Reinhardt, Joseph M; Garvin, Mona K; Abramoff, Michael D

    2014-01-01

    The separation of the retinal vessel network into distinct arterial and venous vessel trees is of high interest. We propose an automated method for identification and separation of retinal vessel trees in a retinal color image by converting a vessel segmentation image into a vessel segment map and identifying the individual vessel trees by graph search. Orientation, width, and intensity of each vessel segment are utilized to find the optimal graph of vessel segments. The separated vessel trees are labeled as primary vessel or branches. We utilize the separated vessel trees for arterial-venous (AV) classification, based on the color properties of the vessels in each tree graph. We applied our approach to a dataset of 50 fundus images from 50 subjects. The proposed method resulted in an accuracy of 91.44% correctly classified vessel pixels as either artery or vein. The accuracy of correctly classified major vessel segments was 96.42%.

  5. Vessel size measurements in angiograms: Manual measurements

    International Nuclear Information System (INIS)

    Hoffmann, Kenneth R.; Dmochowski, Jacek; Nazareth, Daryl P.; Miskolczi, Laszlo; Nemes, Balazs; Gopal, Anant; Wang Zhou; Rudin, Stephen; Bednarek, Daniel R.

    2003-01-01

    Vessel size measurement is perhaps the most often performed quantitative analysis in diagnostic and interventional angiography. Although automated vessel sizing techniques are generally considered to have good accuracy and precision, we have observed that clinicians rarely use these techniques in standard clinical practice, choosing to indicate the edges of vessels and catheters to determine sizes and calibrate magnifications, i.e., manual measurements. Thus, we undertook an investigation of the accuracy and precision of vessel sizes calculated from manually indicated edges of vessels. Manual measurements were performed by three neuroradiologists and three physicists. Vessel sizes ranged from 0.1-3.0 mm in simulation studies and 0.3-6.4 mm in phantom studies. Simulation resolution functions had full-widths-at-half-maximum (FWHM) ranging from 0.0 to 0.5 mm. Phantom studies were performed with 4.5 in., 6 in., 9 in., and 12 in. image intensifier modes, magnification factor = 1, with and without zooming. The accuracy and reproducibility of the measurements ranged from 0.1 to 0.2 mm, depending on vessel size, resolution, and pixel size, and zoom. These results indicate that manual measurements may have accuracies comparable to automated techniques for vessels with sizes greater than 1 mm, but that automated techniques which take into account the resolution function should be used for vessels with sizes smaller than 1 mm

  6. The Greatest Mathematical Discovery?

    Energy Technology Data Exchange (ETDEWEB)

    Bailey, David H.; Borwein, Jonathan M.

    2010-05-12

    What mathematical discovery more than 1500 years ago: (1) Is one of the greatest, if not the greatest, single discovery in the field of mathematics? (2) Involved three subtle ideas that eluded the greatest minds of antiquity, even geniuses such as Archimedes? (3) Was fiercely resisted in Europe for hundreds of years after its discovery? (4) Even today, in historical treatments of mathematics, is often dismissed with scant mention, or else is ascribed to the wrong source? Answer: Our modern system of positional decimal notation with zero, together with the basic arithmetic computational schemes, which were discovered in India about 500 CE.

  7. Accuracy of geometrical modelling of heat transfer from tissue to blood vessels

    NARCIS (Netherlands)

    Leeuwen, van G.M.J.; Kotte, A.N.T.J.; Bree, de J.; Koijk, van der J.F.; Crezee, J.; Lagendijk, J.J.W.

    1997-01-01

    We have developed a thermal model in which blood vessels are described as geometrical objects, 3D curves with associated diameters. Here the behaviour of the model is examined for low resolutions compared with the vessel diameter and for strongly curved vessels. The tests include a single straight

  8. Computed tomography angiogram. Accuracy in renal surgery

    International Nuclear Information System (INIS)

    Rabah, Danny M.; Al-Hathal, Naif; Al-Fuhaid, Turki; Raza, Sayed; Al-Yami, Fahad; Al-Taweel, Waleed; Alomar, Mohamed; Al-Nagshabandi, Nizar

    2009-01-01

    The objective of this study was to determine the sensitivity and specificity of computed tomography angiogram (CTA) in detecting number and location of renal arteries and veins as well as crossing vessels causing uretero-pelvic junction obstruction (UPJO), and to determine if this can be used in decision-making algorithms for treatment of UPJO. A prospective study was carried out in patients undergoing open, laparoscopic and robotic renal surgery from April 2005 until October 2006. All patients were imaged using CTA with 1.25 collimation of arterial and venous phases. Each multi-detector CTA was then read by one radiologist and his results were compared prospectively with the actual intra-operative findings. Overall, 118 patients were included. CTA had 93% sensitivity, 77% specificity and 90% overall accuracy for detecting a single renal artery, and 76% sensitivity, 92% specificity and 90% overall accuracy for detecting two or more renal arteries (Pearson χ 2 =0.001). There was 95% sensitivity, 84% specificity and 85% overall accuracy for detecting the number of renal veins. CTA had 100% overall accuracy in detecting early dividing renal artery (defined as less than 1.5 cm branching from origin), and 83.3% sensitivity, specificity and overall accuracy in detecting crossing vessels at UPJ. The percentage of surgeons stating CTA to be helpful as pre-operative diagnostic tool was 85%. Computed tomography angiogram is simple, quick and can provide an accurate pre-operative renal vascular anatomy in terms of number and location of renal vessels, early dividing renal arteries and crossing vessels at UPJ. (author)

  9. Accuracy and initial clinical experience with measurement software (advanced vessel analysis) in three-dimensional imaging

    International Nuclear Information System (INIS)

    Abe, Toshi; Hirohata, Masaru; Tanigawa, Hitoshi

    2002-01-01

    Recently, the clinical benefits of three dimensional (3D) imaging, such as 3D-CTA and 3D-DSA, in cerebro-vascular disease have been widely recognized. Software for quantitative analysis of vascular structure in 3D imaging (advanced vessel analysis: AVA) has been developed. We evaluated AVA with both phantom studies and a few clinical cases. In spiral and curvy aluminum tube phantom studies, the accuracy of diameter measurements was good in 3D images produced from data set generated by multi-detector row CT or rotational angiography. The measurement error was less than 0.03 mm on aluminum tube phantoms that were 3 mm and 5 mm in diameter. In the clinical studies, the differences of carotid artery diameter measurements between 2D-DSA and 3D-DSA was less than 0.3 mm in. The measurement of length, diameter and angle by AVA should provide useful information for planning surgical and endovascular treatments of cerebro-vascular disease. (author)

  10. The Analysis of the Causes of Emergencies on the Vessels

    Directory of Open Access Journals (Sweden)

    Alicja Mrozowska

    2017-12-01

    Full Text Available The article discusses the results of research conducted on the vessels, covering a wide spectrum of issues relating to the exploitation of vessels of various flags, as well as operating security and safety systems on board. The main aim of the study was to collect numbers of data directly from the crew, for examples: indicate by the crew marine areas with the greatest probability of occurrence of casualties and incidents, trying to the definition the causes of their occurrence, prevention actions used on board and analyses operating safety systems used on the various type of vessels. The analysis of research became the basis to identify strengths and weaknesses areas of the vessel operation. The author proposes a solution to be implemented on board and emphasizes meaning of safety management system.

  11. Automatic Vessel Segmentation on Retinal Images

    Institute of Scientific and Technical Information of China (English)

    Chun-Yuan Yu; Chia-Jen Chang; Yen-Ju Yao; Shyr-Shen Yu

    2014-01-01

    Several features of retinal vessels can be used to monitor the progression of diseases. Changes in vascular structures, for example, vessel caliber, branching angle, and tortuosity, are portents of many diseases such as diabetic retinopathy and arterial hyper-tension. This paper proposes an automatic retinal vessel segmentation method based on morphological closing and multi-scale line detection. First, an illumination correction is performed on the green band retinal image. Next, the morphological closing and subtraction processing are applied to obtain the crude retinal vessel image. Then, the multi-scale line detection is used to fine the vessel image. Finally, the binary vasculature is extracted by the Otsu algorithm. In this paper, for improving the drawbacks of multi-scale line detection, only the line detectors at 4 scales are used. The experimental results show that the accuracy is 0.939 for DRIVE (digital retinal images for vessel extraction) retinal database, which is much better than other methods.

  12. Reliability aspects of radiation damage in reactor pressure vessel mterials

    International Nuclear Information System (INIS)

    Brumovsky, M.

    1985-01-01

    The service life estimate is a major factor in the evaluation of the operating reliability and safety of a nuclear reactor pressure vessel. The evaluation of the service life of the pressure vessel is based on a comparison of fracture toughness values with stress intensity factors. Notch toughness curves are used for the indirect determination of fracture toughness. The dominant degradation effect is radiation embrittlement. Factors having the greatest effect on the result are the properties of the starting material of the vessel and the impurity content, mainly the Cu and P content. The design life is affected by the evaluation of residual lifetime which is made by periodical nondestructive inspections and using surveillance samples. (M.D.)

  13. Comparison of vessel enhancement algorithms applied to time-of-flight MRA images for cerebrovascular segmentation.

    Science.gov (United States)

    Phellan, Renzo; Forkert, Nils D

    2017-11-01

    Vessel enhancement algorithms are often used as a preprocessing step for vessel segmentation in medical images to improve the overall segmentation accuracy. Each algorithm uses different characteristics to enhance vessels, such that the most suitable algorithm may vary for different applications. This paper presents a comparative analysis of the accuracy gains in vessel segmentation generated by the use of nine vessel enhancement algorithms: Multiscale vesselness using the formulas described by Erdt (MSE), Frangi (MSF), and Sato (MSS), optimally oriented flux (OOF), ranking orientations responses path operator (RORPO), the regularized Perona-Malik approach (RPM), vessel enhanced diffusion (VED), hybrid diffusion with continuous switch (HDCS), and the white top hat algorithm (WTH). The filters were evaluated and compared based on time-of-flight MRA datasets and corresponding manual segmentations from 5 healthy subjects and 10 patients with an arteriovenous malformation. Additionally, five synthetic angiographic datasets with corresponding ground truth segmentation were generated with three different noise levels (low, medium, and high) and also used for comparison. The parameters for each algorithm and subsequent segmentation were optimized using leave-one-out cross evaluation. The Dice coefficient, Matthews correlation coefficient, area under the ROC curve, number of connected components, and true positives were used for comparison. The results of this study suggest that vessel enhancement algorithms do not always lead to more accurate segmentation results compared to segmenting nonenhanced images directly. Multiscale vesselness algorithms, such as MSE, MSF, and MSS proved to be robust to noise, while diffusion-based filters, such as RPM, VED, and HDCS ranked in the top of the list in scenarios with medium or no noise. Filters that assume tubular-shapes, such as MSE, MSF, MSS, OOF, RORPO, and VED show a decrease in accuracy when considering patients with an AVM

  14. Nature's Greatest Puzzles

    International Nuclear Information System (INIS)

    Quigg, Chris

    2005-01-01

    It is a pleasure to be part of the SLAC Summer Institute again, not simply because it is one of the great traditions in our field, but because this is a moment of great promise for particle physics. I look forward to exploring many opportunities with you over the course of our two weeks together. My first task in talking about Nature's Greatest Puzzles, the title of this year's Summer Institute, is to deconstruct the premise a little bit

  15. Nuclear reactor pressure vessel flaw distribution development

    International Nuclear Information System (INIS)

    Kennedy, E.L.; Foulds, J.R.; Basin, S.L.

    1991-12-01

    Previous attempts to develop flaw distributions for probabilistic fracture mechanics analyses of pressurized water reactor (PWR) vessels have aimed at the estimation of a ''generic'' distribution applicable to all PWR vessels. In contrast, this report describes (1) a new flaw distribution development analytic methodology that can be applied to the analysis of vessel-specific inservice inspection (ISI) data, and (2) results of the application of the methodology to the analysis of flaw data for each vessel case (ISI data on three PWR vessels and laboratory inspection data on sections of the Midland reactor vessel). Results of this study show significant variation among the flaw distributions derived from the various data sets analyzed, strongly suggesting than a vessel-specific flaw distribution (for vessel integrity prediction under pressurized thermal shock) is preferred over a ''generic'' distribution. In addition, quantitative inspection system flaw sizing accuracy requirements have been identified for developing a flaw distribution from vessel ISI data. The new flaw data analysis methodology also permits quantifying the reliability of the flaw distribution estimate. Included in the report are identified needs for further development of several aspects of ISI data acquisition and vessel integrity prediction practice

  16. Preliminary structural assessment of DEMO vacuum vessel against a vertical displacement event

    International Nuclear Information System (INIS)

    Mozzillo, Rocco; Tarallo, Andrea; Marzullo, Domenico; Bachmann, Christian; Di Gironimo, Giuseppe; Mazzone, Giuseppe

    2016-01-01

    Highlights: • The paper focuses on a preliminary structural analysis of the current concept design of DEMO vacuum vessel. • The Vacuum Vessel was checked against the VDE in combinations with the weight force of all components that the vessel shall bear. • Different configurations for the vacuum vessel supports are considered, showing that the best solution is VV supported at the lower port. • The analyses evaluated the “P damage” according to RCC-MRx code. - Abstract: This paper focuses on a preliminary structural analysis of the current concept design of DEMO vacuum vessel (VV). The VV structure is checked against a vertical load due to a Vertical Displacement Event in combination with the weight force of all components that the main vessel shall bear. Different configurations for the supports are considered. Results show that the greatest safety margins are reached when the tokamak is supported through the lower ports rather than the equatorial ports, though all analyzed configurations are compliant with RCC-MRx design rules.

  17. Preliminary structural assessment of DEMO vacuum vessel against a vertical displacement event

    Energy Technology Data Exchange (ETDEWEB)

    Mozzillo, Rocco, E-mail: rocco.mozzillo@unina.it [CREATE, University of Naples Federico II, DII, P.le Tecchio 80, 80125, Naples (Italy); Tarallo, Andrea; Marzullo, Domenico [CREATE, University of Naples Federico II, DII, P.le Tecchio 80, 80125, Naples (Italy); Bachmann, Christian [EUROfusion PMU, Boltzmannstraße 2, 85748 Garching (Germany); Di Gironimo, Giuseppe [CREATE, University of Naples Federico II, DII, P.le Tecchio 80, 80125, Naples (Italy); Mazzone, Giuseppe [Unità Tecnica Fusione - ENEA C.R. Frascati, Via E. Fermi 45, 00044 Frascati (Italy)

    2016-11-15

    Highlights: • The paper focuses on a preliminary structural analysis of the current concept design of DEMO vacuum vessel. • The Vacuum Vessel was checked against the VDE in combinations with the weight force of all components that the vessel shall bear. • Different configurations for the vacuum vessel supports are considered, showing that the best solution is VV supported at the lower port. • The analyses evaluated the “P damage” according to RCC-MRx code. - Abstract: This paper focuses on a preliminary structural analysis of the current concept design of DEMO vacuum vessel (VV). The VV structure is checked against a vertical load due to a Vertical Displacement Event in combination with the weight force of all components that the main vessel shall bear. Different configurations for the supports are considered. Results show that the greatest safety margins are reached when the tokamak is supported through the lower ports rather than the equatorial ports, though all analyzed configurations are compliant with RCC-MRx design rules.

  18. Computational Physics' Greatest Hits

    Science.gov (United States)

    Bug, Amy

    2011-03-01

    The digital computer, has worked its way so effectively into our profession that now, roughly 65 years after its invention, it is virtually impossible to find a field of experimental or theoretical physics unaided by computational innovation. It is tough to think of another device about which one can make that claim. In the session ``What is computational physics?'' speakers will distinguish computation within the field of computational physics from this ubiquitous importance across all subfields of physics. This talk will recap the invited session ``Great Advances...Past, Present and Future'' in which five dramatic areas of discovery (five of our ``greatest hits'') are chronicled: The physics of many-boson systems via Path Integral Monte Carlo, the thermodynamic behavior of a huge number of diverse systems via Monte Carlo Methods, the discovery of new pharmaceutical agents via molecular dynamics, predictive simulations of global climate change via detailed, cross-disciplinary earth system models, and an understanding of the formation of the first structures in our universe via galaxy formation simulations. The talk will also identify ``greatest hits'' in our field from the teaching and research perspectives of other members of DCOMP, including its Executive Committee.

  19. Evaluation and accuracy of the local velocity data measurements in an agitated vessel

    Directory of Open Access Journals (Sweden)

    Kysela Bohuš

    2014-03-01

    Full Text Available Velocity measurements of the flow field in an agitated vessel are necessary for the improvement and better understanding of the mixing processes. The obtained results are used for the calculations of the impeller pumping capacity, comparison of the power consumption etc. We performed various measurements of the local velocities in an agitated vessel final results of which should be processed for several purposes so it was necessary to make an analysis of the obtained data suitability and their quality. Analysed velocity data were obtained from the LDA (Laser Doppler Anemometry and PIV (Particle Image Velocimetry measurements performed on a standard equipment where the flat bottomed vessel with four baffles was agitated by the six-blade Rushton turbine. The results from both used methods were compared. The frequency analyses were examined as well as the dependency of the data rates, time series lengths etc. The demands for the data processed in the form of the ensemble-averaged results were also established.

  20. Flaw distribution development from vessel ISI data

    International Nuclear Information System (INIS)

    Foulds, J.R.; Kennedy, E.L.; Basin, S.L.; Rosinski, S.T.

    1991-01-01

    Previous attempts to develop flaw distributions for use in the structural integrity evaluation of pressurized water reactor (PWR) vessels have aimed at the estimation of a ''generic'' distribution applicable to all vessels. In contrast, this paper describes the analysis of vessel-specific in-service inspection (ISI) data for the development of a flaw distribution reliably representative of the condition of the particular vessel inspected. The application of the methodology may be extended to other vessels, but has been primarily developed for PWR reactor vessels. For this study, the flaw data analyzed included data obtained from three recently performed PWR vessel ISIs and from laboratory inspection of selected weldment sections of the Midland reactor vessel. The variability in both the character of the reviewed data (size range of flaws, number of flaws) and the UT (ultrasonic test) inspection system performance identified a need for analyzing the inspection results on a vessel-, or data set-specific basis. For this purpose, traditional histogram-based methods were inadequate, and a new methodology that can accept a very small number of flaws (typical of vessel-specific ISI results) and that includes consideration of inspection system flaw detection reliability, flaw sizing accuracy and flaw detection threshold, was developed. Results of the application of the methodology to each of the four PWR reactor vessel cases studied are presented and discussed

  1. Nuclear reactor pressure vessel-specific flaw distribution development

    International Nuclear Information System (INIS)

    Rosinski, S.T.

    1992-01-01

    Vessel integrity predictions performed through fracture mechanics analysis of a pressurized thermal shock event have been shown to be significantly sensitive to the overall flaw distribution input. It has also been shown that modem vessel in-service inspection (ISI) results can be used for development of vessel flaw distribution(s) that are more representative of US vessels. This paper describes the development and application of a methodology to analyze ISI data for the purpose of flaw distribution determination. The resultant methodology considers detection reliability, flaw sizing accuracy, and flaw detection threshold in its application. Application of the methodology was then demonstrated using four recently acquired US PWR vessel inspection data sets. Throughout the program, new insight was obtained into several key inspection performance and vessel integrity prediction practice issues that will impact future vessel integrity evaluation. For example, the potential application of a vessel-specific flaw distribution now provides at least one method by which a vessel-specific reference flaw size applicable to pressure-temperature limit curves determination can be estimated. This paper will discuss the development and application of the methodology and the impact to future vessel integrity analyses

  2. Automatic detection of blood vessels in retinal images for diabetic retinopathy diagnosis.

    Science.gov (United States)

    Raja, D Siva Sundhara; Vasuki, S

    2015-01-01

    Diabetic retinopathy (DR) is a leading cause of vision loss in diabetic patients. DR is mainly caused due to the damage of retinal blood vessels in the diabetic patients. It is essential to detect and segment the retinal blood vessels for DR detection and diagnosis, which prevents earlier vision loss in diabetic patients. The computer aided automatic detection and segmentation of blood vessels through the elimination of optic disc (OD) region in retina are proposed in this paper. The OD region is segmented using anisotropic diffusion filter and subsequentially the retinal blood vessels are detected using mathematical binary morphological operations. The proposed methodology is tested on two different publicly available datasets and achieved 93.99% sensitivity, 98.37% specificity, 98.08% accuracy in DRIVE dataset and 93.6% sensitivity, 98.96% specificity, and 95.94% accuracy in STARE dataset, respectively.

  3. Flaw density examinations of a clad boiling water reactor pressure vessel segment

    International Nuclear Information System (INIS)

    Cook, K.V.; McClung, R.W.

    1986-01-01

    Flaw density is the greatest uncertainty involved in probabilistic analyses of reactor pressure vessel failure. As part of the Heavy-Section Steel Technology (HSST) Program, studies have been conducted to determine flaw density in a section of reactor pressure vessel cut from the Hope Creek Unit 2 vessel [nominally 0.7 by 3 m (2 by 10 ft)]. This section (removed from the scrapped vessel that was never in service) was evaluated nondestructively to determine the as-fabricated status. We had four primary objectives: (1) evaluate longitudinal and girth welds for flaws with manual ultrasonics, (2) evaluate the zone under the nominal 6.3-mm (0.25-in.) clad for cracking (again with manual ultrasonics), (3) evaluate the cladding for cracks with a high-sensitivity fluorescent penetrant method, and (4) determine the source of indications detected

  4. Advanced toroidal facility vaccuum vessel stress analyses

    International Nuclear Information System (INIS)

    Hammonds, C.J.; Mayhall, J.A.

    1987-01-01

    The complex geometry of the Advance Toroidal Facility (ATF) vacuum vessel required special analysis techniques in investigating the structural behavior of the design. The response of a large-scale finite element model was found for transportation and operational loading. Several computer codes and systems, including the National Magnetic Fusion Energy Computer Center Cray machines, were implemented in accomplishing these analyses. The work combined complex methods that taxed the limits of both the codes and the computer systems involved. Using MSC/NASTRAN cyclic-symmetry solutions permitted using only 1/12 of the vessel geometry to mathematically analyze the entire vessel. This allowed the greater detail and accuracy demanded by the complex geometry of the vessel. Critical buckling-pressure analyses were performed with the same model. The development, results, and problems encountered in performing these analyses are described. 5 refs., 3 figs

  5. Automated identification of retinal vessels using a multiscale directional contrast quantification (MDCQ) strategy

    Energy Technology Data Exchange (ETDEWEB)

    Zhen, Yi; Zhang, Xinyuan; Wang, Ningli, E-mail: wningli@vip.163.com, E-mail: puj@upmc.edu [National Engineering Research Center for Ophthalmic Equipments, Beijing, 100730 (China); Gu, Suicheng; Meng, Xin [Imaging Research Center, Department of Radiology, University of Pittsburgh, Pittsburgh, Pennsylvania, 15213 (United States); Zheng, Bin [School of Electrical and Computer Engineering, University of Oklahoma, Norman, Oklahoma 73019 (United States); Pu, Jiantao, E-mail: wningli@vip.163.com, E-mail: puj@upmc.edu [Imaging Research Center, Departments of Radiology and Bioengineering, University of Pittsburgh, Pittsburgh, Pennsylvania, 15213 (United States)

    2014-09-15

    Purpose: A novel algorithm is presented to automatically identify the retinal vessels depicted in color fundus photographs. Methods: The proposed algorithm quantifies the contrast of each pixel in retinal images at multiple scales and fuses the resulting consequent contrast images in a progressive manner by leveraging their spatial difference and continuity. The multiscale strategy is to deal with the variety of retinal vessels in width, intensity, resolution, and orientation; and the progressive fusion is to combine consequent images and meanwhile avoid a sudden fusion of image noise and/or artifacts in space. To quantitatively assess the performance of the algorithm, we tested it on three publicly available databases, namely, DRIVE, STARE, and HRF. The agreement between the computer results and the manual delineation in these databases were quantified by computing their overlapping in both area and length (centerline). The measures include sensitivity, specificity, and accuracy. Results: For the DRIVE database, the sensitivities in identifying vessels in area and length were around 90% and 70%, respectively, the accuracy in pixel classification was around 99%, and the precisions in terms of both area and length were around 94%. For the STARE database, the sensitivities in identifying vessels were around 90% in area and 70% in length, and the accuracy in pixel classification was around 97%. For the HRF database, the sensitivities in identifying vessels were around 92% in area and 83% in length for the healthy subgroup, around 92% in area and 75% in length for the glaucomatous subgroup, around 91% in area and 73% in length for the diabetic retinopathy subgroup. For all three subgroups, the accuracy was around 98%. Conclusions: The experimental results demonstrate that the developed algorithm is capable of identifying retinal vessels depicted in color fundus photographs in a relatively reliable manner.

  6. Detection of Blood Vessels in Color Fundus Images using a Local Radon Transform

    Directory of Open Access Journals (Sweden)

    Reza Pourreza

    2010-09-01

    Full Text Available Introduction: This paper addresses a method for automatic detection of blood vessels in color fundus images which utilizes two main tools: image partitioning and local Radon transform. Material and Methods: The input images are firstly divided into overlapping windows and then the Radon transform is applied to each. The maximum of the Radon transform in each window corresponds to the probable available sub-vessel. To verify the detected sub-vessel, the maximum is compared with a predefined threshold. The verified sub-vessels are reconstructed using the Radon transform information. All detected and reconstructed sub-vessels are finally combined to make the final vessel tree. Results: The algorithm’s performance was evaluated numerically by applying it to 40 images of DRIVE database, a standard retinal image database. The vessels were extracted manually by two physicians. This database was used to test and compare the available and proposed algorithms for vessel detection in color fundus images. By comparing the output of the algorithm with the manual results, the two parameters TPR and FPR were calculated for each image and the average of TPRs and FPRs were used to plot the ROC curve. Discussion and Conclusion: Comparison of the ROC curve of this algorithm with other algorithms demonstrated the high achieved accuracy. Beside the high accuracy, the Radon transform which is integral-based makes the algorithm robust against noise.

  7. Automated classification and quantitative analysis of arterial and venous vessels in fundus images

    Science.gov (United States)

    Alam, Minhaj; Son, Taeyoon; Toslak, Devrim; Lim, Jennifer I.; Yao, Xincheng

    2018-02-01

    It is known that retinopathies may affect arteries and veins differently. Therefore, reliable differentiation of arteries and veins is essential for computer-aided analysis of fundus images. The purpose of this study is to validate one automated method for robust classification of arteries and veins (A-V) in digital fundus images. We combine optical density ratio (ODR) analysis and blood vessel tracking algorithm to classify arteries and veins. A matched filtering method is used to enhance retinal blood vessels. Bottom hat filtering and global thresholding are used to segment the vessel and skeleton individual blood vessels. The vessel tracking algorithm is used to locate the optic disk and to identify source nodes of blood vessels in optic disk area. Each node can be identified as vein or artery using ODR information. Using the source nodes as starting point, the whole vessel trace is then tracked and classified as vein or artery using vessel curvature and angle information. 50 color fundus images from diabetic retinopathy patients were used to test the algorithm. Sensitivity, specificity, and accuracy metrics were measured to assess the validity of the proposed classification method compared to ground truths created by two independent observers. The algorithm demonstrated 97.52% accuracy in identifying blood vessels as vein or artery. A quantitative analysis upon A-V classification showed that average A-V ratio of width for NPDR subjects with hypertension decreased significantly (43.13%).

  8. Crack propagation on spherical pressure vessels

    International Nuclear Information System (INIS)

    Lebey, J.; Roche, R.

    1975-01-01

    The risk presented by a crack on a pressure vessel built with a ductile steel cannot be well evaluated by simple application of the rules of Linear Elastic Fracture Mechanics, which only apply to brittle materials. Tests were carried out on spherical vessels of three different scales built with the same steel. Cracks of different length were machined through the vessel wall. From the results obtained, crack initiation stress (beginning of stable propagation) and instable propagation stress may be plotted against the lengths of these cracks. For small and medium size, subject to ductile fracture, the resulting curves are identical, and may be used for ductile fracture prediction. Brittle rupture was observed on larger vessels and crack propagation occurred at lower stress level. Preceedings curves are not usable for fracture analysis. Ultimate pressure can be computed with a good accuracy by using equivalent energy toughness, Ksub(1cd), characteristic of the metal plates. Satisfactory measurements have been obtained on thin samples. The risks of brittle fracture may then judged by comparing Ksub(1cd) with the calculated K 1 value, in which corrections for vessel shape are taken into account. It is thus possible to establish the bursting pressure of cracked spherical vessels, with the help of two rules, one for brittle fracture, the other for ductile instability. A practical method is proposed on the basis of the work reported here

  9. Probabilistic atlas based labeling of the cerebral vessel tree

    Science.gov (United States)

    Van de Giessen, Martijn; Janssen, Jasper P.; Brouwer, Patrick A.; Reiber, Johan H. C.; Lelieveldt, Boudewijn P. F.; Dijkstra, Jouke

    2015-03-01

    Preoperative imaging of the cerebral vessel tree is essential for planning therapy on intracranial stenoses and aneurysms. Usually, a magnetic resonance angiography (MRA) or computed tomography angiography (CTA) is acquired from which the cerebral vessel tree is segmented. Accurate analysis is helped by the labeling of the cerebral vessels, but labeling is non-trivial due to anatomical topological variability and missing branches due to acquisition issues. In recent literature, labeling the cerebral vasculature around the Circle of Willis has mainly been approached as a graph-based problem. The most successful method, however, requires the definition of all possible permutations of missing vessels, which limits application to subsets of the tree and ignores spatial information about the vessel locations. This research aims to perform labeling using probabilistic atlases that model spatial vessel and label likelihoods. A cerebral vessel tree is aligned to a probabilistic atlas and subsequently each vessel is labeled by computing the maximum label likelihood per segment from label-specific atlases. The proposed method was validated on 25 segmented cerebral vessel trees. Labeling accuracies were close to 100% for large vessels, but dropped to 50-60% for small vessels that were only present in less than 50% of the set. With this work we showed that using solely spatial information of the vessel labels, vessel segments from stable vessels (>50% presence) were reliably classified. This spatial information will form the basis for a future labeling strategy with a very loose topological model.

  10. Improving Intensity-Based Lung CT Registration Accuracy Utilizing Vascular Information

    Directory of Open Access Journals (Sweden)

    Kunlin Cao

    2012-01-01

    Full Text Available Accurate pulmonary image registration is a challenging problem when the lungs have a deformation with large distance. In this work, we present a nonrigid volumetric registration algorithm to track lung motion between a pair of intrasubject CT images acquired at different inflation levels and introduce a new vesselness similarity cost that improves intensity-only registration. Volumetric CT datasets from six human subjects were used in this study. The performance of four intensity-only registration algorithms was compared with and without adding the vesselness similarity cost function. Matching accuracy was evaluated using landmarks, vessel tree, and fissure planes. The Jacobian determinant of the transformation was used to reveal the deformation pattern of local parenchymal tissue. The average matching error for intensity-only registration methods was on the order of 1 mm at landmarks and 1.5 mm on fissure planes. After adding the vesselness preserving cost function, the landmark and fissure positioning errors decreased approximately by 25% and 30%, respectively. The vesselness cost function effectively helped improve the registration accuracy in regions near thoracic cage and near the diaphragm for all the intensity-only registration algorithms tested and also helped produce more consistent and more reliable patterns of regional tissue deformation.

  11. Diagnostic accuracy of dual energy CT angiography in patients with diabetes mellitus

    International Nuclear Information System (INIS)

    Schabel, C.; Bongers, M.N.; Syha, R.; Ketelsen, D.; Homann, G.; Notohamiprodjo, M.; Nikolaou, K.; Bamberg, F.; Thomas, C.

    2015-01-01

    Peripheral arterial disease (PAD) represents a major and highly prevalent complication in patients with diabetes mellitus. The diagnostic, non-invasive work-up by computed tomography angiography (CTA) is limited in the presence of extensive calcification. The aim of the study was to determine the diagnostic accuracy of dual energy CTA (DE-CTA) for the detection and characterization of PAD in patients with diabetes mellitus. In this study 30 diabetic patients with suspected or known PAD were retrospectively included in the analysis. All subjects underwent DE-CTA (Somatom Definition Flash, Siemens Healthcare, Erlangen, Germany) prior to invasive angiography, which served as the reference standard. Blinded analysis included assessment of the presence and degree of peripheral stenosis on curved multiplanar reformatting (MPR) and maximum intensity projections (MIP). Conventional measures of diagnostic accuracy were derived. Among the 30 subjects included in the analysis (83 % male, mean age 70.0 ± 10.5 years, 83 % diabetes type 2), the prevalence of critical stenosis in 331 evaluated vessel segments was high (30 %). Dual energy CT identified critical stenoses with a high sensitivity and good specificity using curved MPR (100 % and 93.1 %, respectively) and MIP images (99 % and 91.8 %, respectively). In stratified analysis, the diagnostic accuracy was higher for stenosis pertaining to the pelvic and thigh vessels as compared with the lower extremities (curved MPR accuracy 97.1 % vs. 99.2 vs. 90.9 %; respectively, p < 0.001). The use of DE-CTA allows reliable detection and characterization of peripheral arterial stenosis in patients with diabetes mellitus with higher accuracy in vessels in the pelvic and thigh regions compared with the vessels in the lower legs. (orig.) [de

  12. Fast Generation of Container Vessel Stowage Plans

    DEFF Research Database (Denmark)

    Pacino, Dario

    that the vessel is stable and seaworthy, and at the same time arrange the cargo such that the time at port is minimized. Moreover, stowage coordinators only have a limited amount of time to produce the plan. This thesis addresses the question of whether it is possible to automatically generate stowage plans...... test instances provided by a major liner shipping company. Improvements to the modeling of vessel stability and an analysis of its accuracy together with an analysis of the computational complexity of the container stowage problem are also included in the thesis, resulting in an overall in...

  13. Vessel Segmentation in Retinal Images Using Multi-scale Line Operator and K-Means Clustering.

    Science.gov (United States)

    Saffarzadeh, Vahid Mohammadi; Osareh, Alireza; Shadgar, Bita

    2014-04-01

    Detecting blood vessels is a vital task in retinal image analysis. The task is more challenging with the presence of bright and dark lesions in retinal images. Here, a method is proposed to detect vessels in both normal and abnormal retinal fundus images based on their linear features. First, the negative impact of bright lesions is reduced by using K-means segmentation in a perceptive space. Then, a multi-scale line operator is utilized to detect vessels while ignoring some of the dark lesions, which have intensity structures different from the line-shaped vessels in the retina. The proposed algorithm is tested on two publicly available STARE and DRIVE databases. The performance of the method is measured by calculating the area under the receiver operating characteristic curve and the segmentation accuracy. The proposed method achieves 0.9483 and 0.9387 localization accuracy against STARE and DRIVE respectively.

  14. Vessel discoloration detection in malarial retinopathy

    Science.gov (United States)

    Agurto, C.; Nemeth, S.; Barriga, S.; Soliz, P.; MacCormick, I.; Taylor, T.; Harding, S.; Lewallen, S.; Joshi, V.

    2016-03-01

    Cerebral malaria (CM) is a life-threatening clinical syndrome associated with malarial infection. It affects approximately 200 million people, mostly sub-Saharan African children under five years of age. Malarial retinopathy (MR) is a condition in which lesions such as whitening and vessel discoloration that are highly specific to CM appear in the retina. Other unrelated diseases can present with symptoms similar to CM, therefore the exact nature of the clinical symptoms must be ascertained in order to avoid misdiagnosis, which can lead to inappropriate treatment and, potentially, death. In this paper we outline the first system to detect the presence of discolored vessels associated with MR as a means to improve the CM diagnosis. We modified and improved our previous vessel segmentation algorithm by incorporating the `a' channel of the CIELab color space and noise reduction. We then divided the segmented vasculature into vessel segments and extracted features at the wall and in the centerline of the segment. Finally, we used a regression classifier to sort the segments into discolored and not-discolored vessel classes. By counting the abnormal vessel segments in each image, we were able to divide the analyzed images into two groups: normal and presence of vessel discoloration due to MR. We achieved an accuracy of 85% with sensitivity of 94% and specificity of 67%. In clinical practice, this algorithm would be combined with other MR retinal pathology detection algorithms. Therefore, a high specificity can be achieved. By choosing a different operating point in the ROC curve, our system achieved sensitivity of 67% with specificity of 100%.

  15. Covering women's greatest health fear: breast cancer information in consumer magazines.

    Science.gov (United States)

    Walsh-Childers, Kim; Edwards, Heather; Grobmyer, Stephen

    2011-04-01

    Women identify consumer magazines as a key source of information on many health topics, including breast cancer, which continues to rank as women's greatest personal health fear. This study examined the comprehensiveness and accuracy of breast cancer information provided in 555 articles published in 17 consumer magazines from 2002 through 2007. Accuracy of information was determined for 33 key breast cancer facts identified by an expert panel as important information for women to know. The results show that only 7 of 33 key facts were mentioned in at least 5% of the articles. These facts all dealt with breast cancer risk factors, screening, and detection; none of the key facts related to treatment or outcomes appeared in at least 5% of the articles. Other topics (not key facts) mentioned centered around controllable risk factors, support for breast cancer patients, and chemotherapy treatment. The majority of mentions of key facts were coded as fully accurate, although as much as 44% of mentions of some topics (the link between hormone replacement therapy and breast cancer) were coded as inaccurate or only partially accurate. The magazines were most likely to emphasize family history of breast cancer or genetic characteristics as risk factors for breast cancers; family history was twice as likely to be discussed as increasing age, which is in fact the most important risk factor for breast cancer other than being female. Magazine coverage may contribute to women's inaccurate perceptions of their breast cancer risk.

  16. Significance of 'Bridging vessel sign' on color Doppler ultrasound in diagnosis of uterine subserosal leiomyoma

    International Nuclear Information System (INIS)

    Lee, Jin Hee; Lee, Jung Hee; Sohn, Chul Ho; Woo, Seung Koo; Kim, Jung Sik

    2002-01-01

    To evaluate the usefulness of the 'bridging vessel sign' in differentiating uterine subserosal leiomyoma from other pelvic masses mimicking leiomyoma on color Doppler ultrasound. Histologically (n=58) and clinically (n=1) proven 59 masses from 55 women were included in this study. Histologic diagnoses included leiomyoma (n=32) and various kinds of other masses (n=27). On gray scale ultrasound, the size of tumor and presence of the ovaries were recorded. On color Doppler ultrasound, the presence of 'bridging vessel sign', which was defined as a linear vessel demonstrated between the mass and the uterus was documented. Uterine subserosal leiomyoma was diagnosed on the basis of finding this sign, and the diagnostic accuracy of this sign in differentiating subserosal leiomyoma from other pelvic tumors was calculated. In addition, the diagnostic accuracy of this sign combined with the visibility of theopsilateral ovary was compared. The size of subserosal leiomyomas ranged from 4.2 to 22.1 cm (mean, 8.3 cm) while the size of other pelvic masses, from 4.6 to 21.5 cm (mean, 9.6 cm). The 'bridging vessel sign' was demonstrated in thirty of 32 leiomyomas and in three of 27 other pelvis masses. The sensitivity, specificity, accuracy, positive predictive value, and negative value of the 'bridging vessel sign' in the diagnosis of subserosal leiomyoma were 93.8%, 99.9%, 91.5%, 90.9% and 92.3%, respectively. The detection of the ipsilateral ovary was possible in 14 of 30 women with leiomyomas and in four of 25 women with other pelvic masses. The sensitivity, specificity, accuracy, positive predictive value and negative predictive value of this finding in the diagnosis of subserosal leiomyoma were 46.7%, 84.0%, 63.6%, 77.8%, and 56.8%, respectively. 'Bridging vessel sign' can be an useful finding in the differential diagnosis of subserosal leiomyomas from other pelvic masses mimicking leiomyoma.

  17. Retinal Vessel Segmentation Based on Primal-Dual Asynchronous Particle Swarm Optimisation (pdAPSO Algorithm

    Directory of Open Access Journals (Sweden)

    E. G. Dada

    2017-04-01

    Full Text Available Acute damage to the retina vessel has been identified to be main reason for blindness and impaired vision all over the world. A timely detection and control of these illnesses can greatly decrease the number of loss of sight cases. Developing a high performance unsupervised retinal vessel segmentation technique poses an uphill task. This paper presents study on the Primal-Dual Asynchronous Particle Swarm Optimisation (pdAPSO method for the segmentation of retinal vessels. A maximum average accuracy rate 0.9243 with an average specificity of sensitivity rate of 0.9834 and average sensitivity rate of 0.5721 were achieved on DRIVE database. The proposed method produces higher mean sensitivity and accuracy rates in the same range of very good specificity.

  18. Safety margins of PWR irradiated vessels - The Chooz A issue

    Energy Technology Data Exchange (ETDEWEB)

    Hedin, F; Barthelet, B [Electricite de France (EDF), 75 - Paris (France); Guilleret, J C

    1988-12-31

    In 1986, some irradiated specimen of CHOOZ A (SENA) vessel showed a significant excess of {delta} RTNDT to former previsions. The lack of data on one of the two irradiated shells, and discrepancies between dosimeters results and available previous fluence calculations whose accuracy was questionable, cause the safety authorities to require an important complementary work program before putting again the plant on the grid after 1987 fuel reloading. These works are presented and discussed. They lead to a state that a conservative to day value of the vessel RTNDT is 64 degrees Celsius and that there is no underclad defect in the vessel wall and welds. Then the plant was allowed to restart with certitude that vessel irradiation will not impair its lifetime. (author). 4 refs.

  19. Vessel size measurements in angiograms: A comparison of techniques

    International Nuclear Information System (INIS)

    Hoffmann, Kenneth R.; Nazareth, Daryl P.; Miskolczi, Laszlo; Gopal, Anant; Wang Zhou; Rudin, Stephen; Bednarek, Daniel R.

    2002-01-01

    As interventional procedures become more complicated, the need for accurate quantitative vascular information increases. In response to this need, many commercial vendors provide techniques for measurement of vessel sizes, usually based on derivative techniques. In this study, we investigate the accuracy of several techniques used in the measurement of vessel size. Simulated images of vessels having circular cross sections were generated and convolved with various focal spot distributions taking into account the magnification. These vessel images were then convolved with Gaussian image detector line spread functions (LSFs). Additionally, images of a phantom containing vessels with a range of diameters were acquired for the 4.5'', 6'', 9'', and 12'' modes of an image intensifier-TV (II-TV) system. Vessel sizes in the images were determined using a first-derivative technique, a second-derivative technique, a linear combination of these two measured sizes, a thresholding technique, a densitometric technique, and a model-based technique. For the same focal spot size, the shape of the focal spot distribution does not affect measured vessel sizes except at large magnifications. For vessels with diameters larger than the full-width-at-half-maximum (FWHM) of the LSF, accurate vessel sizes (errors ∼0.1 mm) could be obtained by using an average of sizes determined by the first and second derivatives. For vessels with diameters smaller than the FWHM of the LSF, the densitometric and model-based techniques can provide accurate vessel sizes when these techniques are properly calibrated

  20. Testing of VVER reactor pressure vessels by TOFD method

    International Nuclear Information System (INIS)

    Skala, Z.; Vit, J.

    2002-01-01

    The Time of Flight Diffraction Method (TOFD) - one of the new testing methods capable to obtain the real dimensions of flaws - is presented in the paper.The laboratory experiments on samples with artificial flaws and samples with artificially prepared cracks confirmed the high accuracy of flaw through wall extent sizing by TOFD. This accuracy was confirmed by qualification of methods and systems used by Skoda JS for the in-service inspections of WWER 440 vessel circumferential weld. The qualification also confirmed the ability of TOFD to detect reliably flaws, which can are not reliably detected by standard pulse echo testing. Based on the result of experiments and qualification, the TOFD method shall be used routinely by Skoda JS for the inspection of vessel circumferential welds root area and for sizing of flaws exceeding the acceptance level

  1. Fast retinal vessel detection and measurement using wavelets and edge location refinement.

    Directory of Open Access Journals (Sweden)

    Peter Bankhead

    Full Text Available The relationship between changes in retinal vessel morphology and the onset and progression of diseases such as diabetes, hypertension and retinopathy of prematurity (ROP has been the subject of several large scale clinical studies. However, the difficulty of quantifying changes in retinal vessels in a sufficiently fast, accurate and repeatable manner has restricted the application of the insights gleaned from these studies to clinical practice. This paper presents a novel algorithm for the efficient detection and measurement of retinal vessels, which is general enough that it can be applied to both low and high resolution fundus photographs and fluorescein angiograms upon the adjustment of only a few intuitive parameters. Firstly, we describe the simple vessel segmentation strategy, formulated in the language of wavelets, that is used for fast vessel detection. When validated using a publicly available database of retinal images, this segmentation achieves a true positive rate of 70.27%, false positive rate of 2.83%, and accuracy score of 0.9371. Vessel edges are then more precisely localised using image profiles computed perpendicularly across a spline fit of each detected vessel centreline, so that both local and global changes in vessel diameter can be readily quantified. Using a second image database, we show that the diameters output by our algorithm display good agreement with the manual measurements made by three independent observers. We conclude that the improved speed and generality offered by our algorithm are achieved without sacrificing accuracy. The algorithm is implemented in MATLAB along with a graphical user interface, and we have made the source code freely available.

  2. Development and application of an LWR reactor pressure vessel-specific flaw distribution

    International Nuclear Information System (INIS)

    Rosinski, S.T.; Kennedy, E.L.; Foulds, J.R.

    1991-01-01

    Previous efforts by the US Department of Energy have shown that the PWR reactor vessel integrity predictions performed through probabilistic fracture mechanics analysis for a pressurized thermal shock event are significantly sensitive to the overall flaw distribution input. It has also been shown that modern vessel in-service inspection (ISI) results can be used for development of vessel flaw distribution(s) that are more representative of US vessels. This paper describes the development and application of a methodology to analyze ISI data for the purpose of flaw distribution determination. The resultant methodology considers detection reliability, flaw sizing accuracy, and flaw detection threshold in its application. Application of the methodology was then demonstrated using four recently acquired US PWR vessel inspection data sets. The methodology helped provide original insight into several key inspection performance and vessel integrity prediction practice issues that will impact future vessel integrity evaluation. This paper briefly discusses the development and application of the methodology and the impact to future vessel integrity analyses

  3. Supervised retinal vessel segmentation from color fundus images based on matched filtering and AdaBoost classifier.

    Directory of Open Access Journals (Sweden)

    Nogol Memari

    Full Text Available The structure and appearance of the blood vessel network in retinal fundus images is an essential part of diagnosing various problems associated with the eyes, such as diabetes and hypertension. In this paper, an automatic retinal vessel segmentation method utilizing matched filter techniques coupled with an AdaBoost classifier is proposed. The fundus image is enhanced using morphological operations, the contrast is increased using contrast limited adaptive histogram equalization (CLAHE method and the inhomogeneity is corrected using Retinex approach. Then, the blood vessels are enhanced using a combination of B-COSFIRE and Frangi matched filters. From this preprocessed image, different statistical features are computed on a pixel-wise basis and used in an AdaBoost classifier to extract the blood vessel network inside the image. Finally, the segmented images are postprocessed to remove the misclassified pixels and regions. The proposed method was validated using publicly accessible Digital Retinal Images for Vessel Extraction (DRIVE, Structured Analysis of the Retina (STARE and Child Heart and Health Study in England (CHASE_DB1 datasets commonly used for determining the accuracy of retinal vessel segmentation methods. The accuracy of the proposed segmentation method was comparable to other state of the art methods while being very close to the manual segmentation provided by the second human observer with an average accuracy of 0.972, 0.951 and 0.948 in DRIVE, STARE and CHASE_DB1 datasets, respectively.

  4. Nature's Greatest Puzzles

    Energy Technology Data Exchange (ETDEWEB)

    Quigg, Chris; /Fermilab

    2005-02-01

    It is a pleasure to be part of the SLAC Summer Institute again, not simply because it is one of the great traditions in our field, but because this is a moment of great promise for particle physics. I look forward to exploring many opportunities with you over the course of our two weeks together. My first task in talking about Nature's Greatest Puzzles, the title of this year's Summer Institute, is to deconstruct the premise a little bit.

  5. Optical Coherence Tomography Angiography Vessel Density in Healthy, Glaucoma Suspect, and Glaucoma Eyes

    Science.gov (United States)

    Yarmohammadi, Adeleh; Zangwill, Linda M.; Diniz-Filho, Alberto; Suh, Min Hee; Manalastas, Patricia Isabel; Fatehee, Naeem; Yousefi, Siamak; Belghith, Akram; Saunders, Luke J.; Medeiros, Felipe A.; Huang, David; Weinreb, Robert N.

    2016-01-01

    Purpose The purpose of this study was to compare retinal nerve fiber layer (RNFL) thickness and optical coherence tomography angiography (OCT-A) retinal vasculature measurements in healthy, glaucoma suspect, and glaucoma patients. Methods Two hundred sixty-one eyes of 164 healthy, glaucoma suspect, and open-angle glaucoma (OAG) participants from the Diagnostic Innovations in Glaucoma Study with good quality OCT-A images were included. Retinal vasculature information was summarized as a vessel density map and as vessel density (%), which is the proportion of flowing vessel area over the total area evaluated. Two vessel density measurements extracted from the RNFL were analyzed: (1) circumpapillary vessel density (cpVD) measured in a 750-μm-wide elliptical annulus around the disc and (2) whole image vessel density (wiVD) measured over the entire image. Areas under the receiver operating characteristic curves (AUROC) were used to evaluate diagnostic accuracy. Results Age-adjusted mean vessel density was significantly lower in OAG eyes compared with glaucoma suspects and healthy eyes. (cpVD: 55.1 ± 7%, 60.3 ± 5%, and 64.2 ± 3%, respectively; P glaucoma and healthy eyes, the age-adjusted AUROC was highest for wiVD (0.94), followed by RNFL thickness (0.92) and cpVD (0.83). The AUROCs for differentiating between healthy and glaucoma suspect eyes were highest for wiVD (0.70), followed by cpVD (0.65) and RNFL thickness (0.65). Conclusions Optical coherence tomography angiography vessel density had similar diagnostic accuracy to RNFL thickness measurements for differentiating between healthy and glaucoma eyes. These results suggest that OCT-A measurements reflect damage to tissues relevant to the pathophysiology of OAG. PMID:27409505

  6. Calibrating a large slab vessel: A battle of the bulge

    International Nuclear Information System (INIS)

    Thomas, I.R.

    1993-01-01

    Slab tanks (critically-safe-by-geometry vessels) were proposed for the storage of concentrated, highly-enriched uranium solution in the design of the Fuel Processing Restoration (FPR) Facility at the Idaho Chemical Processing Plant (ICPP). Currently, measurements of bulk mass in ICPP annular vessels have standard deviations on the order of 0.2%, or less. ICPP personnel felt that their inexperience with the aforementioned expansions would prevent them from attaining comparable precision with slab tanks. To help assess the measurement accuracy of slab vessels, a full-scale mockup of those proposed for the FPR Facility was installed for test calibrations. These calibrations were designed to detect vessel expansion under differing conditions. This paper will compare the base-line, water calibrations with those of the higher-density aluminum nitrate, and any observed deflection will be described using vessel calibration techniques. The calibration using water at an elevated temperature was not performed due to the difficulty of maintaining the elevated temperature. This calibration probably will not be conducted because the construction of the FPR Facility has been halted

  7. Application of morphological bit planes in retinal blood vessel extraction.

    Science.gov (United States)

    Fraz, M M; Basit, A; Barman, S A

    2013-04-01

    The appearance of the retinal blood vessels is an important diagnostic indicator of various clinical disorders of the eye and the body. Retinal blood vessels have been shown to provide evidence in terms of change in diameter, branching angles, or tortuosity, as a result of ophthalmic disease. This paper reports the development for an automated method for segmentation of blood vessels in retinal images. A unique combination of methods for retinal blood vessel skeleton detection and multidirectional morphological bit plane slicing is presented to extract the blood vessels from the color retinal images. The skeleton of main vessels is extracted by the application of directional differential operators and then evaluation of combination of derivative signs and average derivative values. Mathematical morphology has been materialized as a proficient technique for quantifying the retinal vasculature in ocular fundus images. A multidirectional top-hat operator with rotating structuring elements is used to emphasize the vessels in a particular direction, and information is extracted using bit plane slicing. An iterative region growing method is applied to integrate the main skeleton and the images resulting from bit plane slicing of vessel direction-dependent morphological filters. The approach is tested on two publicly available databases DRIVE and STARE. Average accuracy achieved by the proposed method is 0.9423 for both the databases with significant values of sensitivity and specificity also; the algorithm outperforms the second human observer in terms of precision of segmented vessel tree.

  8. Effects of cognitive training on change in accuracy in inductive reasoning ability.

    Science.gov (United States)

    Boron, Julie Blaskewicz; Turiano, Nicholas A; Willis, Sherry L; Schaie, K Warner

    2007-05-01

    We investigated cognitive training effects on accuracy and number of items attempted in inductive reasoning performance in a sample of 335 older participants (M = 72.78 years) from the Seattle Longitudinal Study. We assessed the impact of individual characteristics, including chronic disease. The reasoning training group showed significantly greater gain in accuracy and number of attempted items than did the comparison group; gain was primarily due to enhanced accuracy. Reasoning training effects involved a complex interaction of gender, prior cognitive status, and chronic disease. Women with prior decline on reasoning but no heart disease showed the greatest accuracy increase. In addition, stable reasoning-trained women with heart disease demonstrated significant accuracy gain. Comorbidity was associated with less change in accuracy. The results support the effectiveness of cognitive training on improving the accuracy of reasoning performance.

  9. Significance of 'Bridging vessel sign' on color Doppler ultrasound in diagnosis of uterine subserosal leiomyoma

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Jin Hee; Lee, Jung Hee; Sohn, Chul Ho; Woo, Seung Koo [Keimyung University School of Medicine, Taegu (Korea, Republic of); Kim, Jung Sik [Radiological Clinic, Taegu (Korea, Republic of)

    2002-06-15

    To evaluate the usefulness of the 'bridging vessel sign' in differentiating uterine subserosal leiomyoma from other pelvic masses mimicking leiomyoma on color Doppler ultrasound. Histologically (n=58) and clinically (n=1) proven 59 masses from 55 women were included in this study. Histologic diagnoses included leiomyoma (n=32) and various kinds of other masses (n=27). On gray scale ultrasound, the size of tumor and presence of the ovaries were recorded. On color Doppler ultrasound, the presence of 'bridging vessel sign', which was defined as a linear vessel demonstrated between the mass and the uterus was documented. Uterine subserosal leiomyoma was diagnosed on the basis of finding this sign, and the diagnostic accuracy of this sign in differentiating subserosal leiomyoma from other pelvic tumors was calculated. In addition, the diagnostic accuracy of this sign combined with the visibility of theopsilateral ovary was compared. The size of subserosal leiomyomas ranged from 4.2 to 22.1 cm (mean, 8.3 cm) while the size of other pelvic masses, from 4.6 to 21.5 cm (mean, 9.6 cm). The 'bridging vessel sign' was demonstrated in thirty of 32 leiomyomas and in three of 27 other pelvis masses. The sensitivity, specificity, accuracy, positive predictive value, and negative value of the 'bridging vessel sign' in the diagnosis of subserosal leiomyoma were 93.8%, 99.9%, 91.5%, 90.9% and 92.3%, respectively. The detection of the ipsilateral ovary was possible in 14 of 30 women with leiomyomas and in four of 25 women with other pelvic masses. The sensitivity, specificity, accuracy, positive predictive value and negative predictive value of this finding in the diagnosis of subserosal leiomyoma were 46.7%, 84.0%, 63.6%, 77.8%, and 56.8%, respectively. 'Bridging vessel sign' can be an useful finding in the differential diagnosis of subserosal leiomyomas from other pelvic masses mimicking leiomyoma.

  10. AN EFFICIENT TECHNIQUE FOR RETINAL VESSEL SEGMENTATION AND DENOISING USING MODIFIED ISODATA AND CLAHE

    Directory of Open Access Journals (Sweden)

    Khan Bahadar Khan

    2016-11-01

    Full Text Available Retinal damage caused due to complications of diabetes is known as Diabetic Retinopathy (DR. In this case, the vision is obscured due to the damage of retinal tinny blood vessels of the retina. These tinny blood vessels may cause leakage which affect the vision and can lead to complete blindness. Identification of these new retinal vessels and their structure is essential for analysis of DR. Automatic blood vessels segmentation plays a significant role to assist subsequent automatic methodologies that aid to such analysis. In literature most of the people have used computationally hungry a strong preprocessing steps followed by a simple thresholding and post processing, But in our proposed technique we utilize an arrangement of  light pre-processing which consists of Contrast Limited Adaptive Histogram Equalization (CLAHE for contrast enhancement, a difference image of green channel from its Gaussian blur filtered image to remove local noise or geometrical object, Modified Iterative Self Organizing Data Analysis Technique (MISODATA for segmentation of vessel and non-vessel pixels based on global and local thresholding, and a strong  post processing using region properties (area, eccentricity to eliminate the unwanted region/segment, non-vessel pixels and noise that never been used to reject misclassified foreground pixels. The strategy is tested on the publically accessible DRIVE (Digital Retinal Images for Vessel Extraction and STARE (STructured Analysis of the REtina databases. The performance of proposed technique is assessed comprehensively and the acquired accuracy, robustness, low complexity and high efficiency and very less computational time that make the method an efficient tool for automatic retinal image analysis. Proposed technique perform well as compared to the existing strategies on the online available databases in term of accuracy, sensitivity, specificity, false positive rate, true positive rate and area under receiver

  11. High-resolution 3D Magnetic Resonance angiography in the evaluation of neck vessels and intracranial circulation

    International Nuclear Information System (INIS)

    Villa, A.; Di Guglielmo, L.; Campani, R.; Nicolato, A.; D'Amato, M.; Rodriguez y Balena, R.

    1991-01-01

    Magnetic Resonance Angiography (MRA) is a modern vascular imaging technique which allows the non-invasive and direct imaging of vessels. The authors aimed at evaluating the diagnostic accuracy of MRA in the study of pathologic conditions in the neck and intracranial vessels; spatial resolution of the technique was also investigated. Twenty-four healthy volunteers and 82 patients suffering from various diseases of the head and neck vessels were included in the study. First of all, MRA capabilities ware investigated in visualizing normal vessels of both neck and intracranial circle. The diagnostic accuracy of the method was then evaluated in the study of vascular diseases, and the results compared with conventional/digital angiographic findings. The comparison demonstrated how stenoses and atherosclerotic plaques tend to be overestimated by MRA because of technical artifacts inherent to the technique itself, whereas vascular ulcerations and aneurysms are frequently underestimated. However, this data was steady and therefore evaluable- the exact knowledge of the artifacts making diagnosis reliable. The diagnostic and technical problems relative to the various vascular diseases are discussed. Finally, several hypotheses of diagnostic iter are suggested

  12. The case for using vessel-based systems to apply oil-spill dispersants

    International Nuclear Information System (INIS)

    Ross, S.

    1998-01-01

    Most emergency plans for dealing with marine oil spills include the use of chemical dispersants. This paper presents a comparison between the capabilities of aircraft-based dispersant application systems and vessel-based systems. The comparison was presented in terms of the logistics of treating offshore spills. Vessel-based systems have certain advantages in terms of their availability and cost. They have better spray control and accuracy and can dose thick slicks in one pass. However, this advantage is lost if the dispersant payload on the vessel is relatively small and the spill is located very far from the base of operations. Under certain conditions, vessel-based dispersant application systems can treat spills as quickly as aircraft-based systems. Most marine spills tend to occur in restricted waters near ports where dispersant stockpiles could be stored for ready use by vessels in the area. Development of a modern vessel-based, fire-monitor system for applying chemical dispersant onto marine oil spills was one of the recommendations emerging from the study. 32 refs., 6 tabs., 1 fig

  13. Design of the prestressed concrete reactor vessel for gas-cooled heating reactors

    International Nuclear Information System (INIS)

    Becker, G.; Notheisen, C.; Steffen, G.

    1987-01-01

    The GHR pebble bed reactor offers a simple, safe and economic possibility of heat generation. An essential component of this concept is the prestressed concrete reactor vessel. A system of cooling pipes welded to the outer surface of the liner is used to transfer the heat from the reactor to the intermediate circuit. The high safety of this vessel concept results from the clear separation of the functions of the individual components and from the design principle of the prestressed conncrete. The prestressed concrete structure is so designed that failure can be reliably ruled out under all operating and accident conditions. Even in the extremely improbable event of failure of all decay heat removal systems when decay heat and accumulated heat are transferred passively by natural convection only, the integrity of the vessel remains intact. For reasons of plant availability the liner and the liner cooling system shall be designed so as to ensure safe elimination of failure over the total operating life. The calculations which were peformed partly on the basis of extremely adverse assumption, also resulted in very low loads. The prestressed concrete vessel is prefabricated to the greatest possible extent. Thus a high quality and optimized fabrication technology can be achieved especially for the liner and the liner cooling system. (orig./HP)

  14. Improvement of retinal blood vessel detection using morphological component analysis.

    Science.gov (United States)

    Imani, Elaheh; Javidi, Malihe; Pourreza, Hamid-Reza

    2015-03-01

    Detection and quantitative measurement of variations in the retinal blood vessels can help diagnose several diseases including diabetic retinopathy. Intrinsic characteristics of abnormal retinal images make blood vessel detection difficult. The major problem with traditional vessel segmentation algorithms is producing false positive vessels in the presence of diabetic retinopathy lesions. To overcome this problem, a novel scheme for extracting retinal blood vessels based on morphological component analysis (MCA) algorithm is presented in this paper. MCA was developed based on sparse representation of signals. This algorithm assumes that each signal is a linear combination of several morphologically distinct components. In the proposed method, the MCA algorithm with appropriate transforms is adopted to separate vessels and lesions from each other. Afterwards, the Morlet Wavelet Transform is applied to enhance the retinal vessels. The final vessel map is obtained by adaptive thresholding. The performance of the proposed method is measured on the publicly available DRIVE and STARE datasets and compared with several state-of-the-art methods. An accuracy of 0.9523 and 0.9590 has been respectively achieved on the DRIVE and STARE datasets, which are not only greater than most methods, but are also superior to the second human observer's performance. The results show that the proposed method can achieve improved detection in abnormal retinal images and decrease false positive vessels in pathological regions compared to other methods. Also, the robustness of the method in the presence of noise is shown via experimental result. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  15. Stress analysis of pressure vessels in nuclear power plants: pt.2

    International Nuclear Information System (INIS)

    Kim, C.W.; Chu, Y.W.

    1976-01-01

    Stress analysis of tapered cylinder of reactor vessels in investigated by means of the intersection method. The tapered cylinder is approximated into three models average cylinder, conical frustum, and ring. The results are compared with those of the finite element method program and an experiment. In this paper, the following results are obtained: (1) the best approximation has been obtained by the ring model analysis: (2) the intersection analysis of the tapered cylinder by the ring model shows a sufficient accuracy for the stress analysis of reactor vessels. (author)

  16. Accuracy of 16-slice multi-detector CT to quantify the degree of coronary artery stenosis: Assessment of cross-sectional and longitudinal vessel reconstructions

    Energy Technology Data Exchange (ETDEWEB)

    Cury, Ricardo C. [Department of Radiology, Massachusetts General Hospital, Boston, MA (United States)]. E-mail: rcury@partners.org; Ferencik, Maros [Department of Radiology, Massachusetts General Hospital, Boston, MA (United States); Achenbach, Stephan [Department of Radiology, Massachusetts General Hospital, Boston, MA (United States); Division of Cardiology, Massachusetts General Hospital, Boston, MA (United States); Department of Internal Medicine II, University of Erlangen (Germany); Pomerantsev, Eugene [Division of Cardiology, Massachusetts General Hospital, Boston, MA (United States); Nieman, Koen [Department of Radiology, Massachusetts General Hospital, Boston, MA (United States); Moselewski, Fabian [Department of Radiology, Massachusetts General Hospital, Boston, MA (United States); Division of Cardiology, Massachusetts General Hospital, Boston, MA (United States); Abbara, Suhny [Department of Radiology, Massachusetts General Hospital, Boston, MA (United States); Jang, Ik-Kyung [Division of Cardiology, Massachusetts General Hospital, Boston, MA (United States); Brady, Thomas J. [Department of Radiology, Massachusetts General Hospital, Boston, MA (United States); Hoffmann, Udo [Department of Radiology, Massachusetts General Hospital, Boston, MA (United States)

    2006-03-15

    Background: Sixteen-slice multi-detector computed tomography (MDCT) permits reliable noninvasive detection of significant coronary stenosis based on qualitative visual assessment. The purpose of this study was to determine the accuracy of MDCT to quantify the degree of coronary stenosis as compared to quantitative coronary angiography (QCA) using two different reconstruction methods. Methods: We studied 69 coronary artery lesions from 38 consecutive patients that underwent 16-slice MDCT as a part of research study, which enrolled consecutive subjects scheduled for clinically indicated invasive coronary angiography. Nine coronary artery lesions with motion artifacts, heavily calcified plaques or stents were excluded from the analysis. The degree of stenosis was calculated by two independent readers non-blinded to the location of the stenosis, but blinded to the results of the QCA. MDCT luminal diameters were measured in cross-sectional multi-planar reformatted (CS-MPR) images created perpendicular to the centerline of the vessel and in 5 mm thin-slab maximum intensity projections (MIP) parallel to the long axis of the vessel. Both MDCT methods were compared against QCA. Results: The mean degree of stenosis as measured by MDCT was closely correlated to QCA for both methods (CS-MPR versus QCA: 61 {+-} 23% versus 64 {+-} 29%; r {sup 2} = 0.83, p < 0.001 and MIP versus QCA: 64 {+-} 22% versus 64 {+-} 29%; r {sup 2} = 0.84, p < 0.001 for MIP. Bland-Altman analysis demonstrated a negative bias of the degree of stenosis of -2.8 {+-} 12% using CS-MPR and a minimally positive bias of 0.6 {+-} 12% for MIP. In stratified analysis for lesion severity (mild, 0-40%; moderate, 41-70% or severe, >70%) the agreement between both CS-MPR and MIP was high when compared to QCA ({kappa} = 0.74 and 0.71, respectively). Conclusion: Multi-detector spiral CT permits accurate quantitative assessment of the degree of coronary stenosis in selected data sets of sufficient quality using both

  17. Development of advanced manufacturing technologies for low cost hydrogen storage vessels

    Energy Technology Data Exchange (ETDEWEB)

    Leavitt, Mark [Quantum Fuel Systems Technologies Worldwide, Inc., Irvine, CA (United States); Lam, Patrick [Boeing Research and Technology (BR& T), Seattle, WA (United States)

    2014-12-29

    The U.S. Department of Energy (DOE) defined a need for low-cost gaseous hydrogen storage vessels at 700 bar to support cost goals aimed at 500,000 units per year. Existing filament winding processes produce a pressure vessel that is structurally inefficient, requiring more carbon fiber for manufacturing reasons, than would otherwise be necessary. Carbon fiber is the greatest cost driver in building a hydrogen pressure vessel. The objective of this project is to develop new methods for manufacturing Type IV pressure vessels for hydrogen storage with the purpose of lowering the overall product cost through an innovative hybrid process of optimizing composite usage by combining traditional filament winding (FW) and advanced fiber placement (AFP) techniques. A numbers of vessels were manufactured in this project. The latest vessel design passed all the critical tests on the hybrid design per European Commission (EC) 79-2009 standard except the extreme temperature cycle test. The tests passed include burst test, cycle test, accelerated stress rupture test and drop test. It was discovered the location where AFP and FW overlap for load transfer could be weakened during hydraulic cycling at 85°C. To design a vessel that passed these tests, the in-house modeling software was updated to add capability to start and stop fiber layers to simulate the AFP process. The original in-house software was developed for filament winding only. Alternative fiber was also investigated in this project, but the added mass impacted the vessel cost negatively due to the lower performance from the alternative fiber. Overall the project was a success to show the hybrid design is a viable solution to reduce fiber usage, thus driving down the cost of fuel storage vessels. Based on DOE’s baseline vessel size of 147.3L and 91kg, the 129L vessel (scaled to DOE baseline) in this project shows a 32% composite savings and 20% cost savings when comparing Vessel 15 hybrid design and the Quantum

  18. OceanRoute: Vessel Mobility Data Processing and Analyzing Model Based on MapReduce

    Science.gov (United States)

    Liu, Chao; Liu, Yingjian; Guo, Zhongwen; Jing, Wei

    2018-06-01

    The network coverage is a big problem in ocean communication, and there is no low-cost solution in the short term. Based on the knowledge of Mobile Delay Tolerant Network (MDTN), the mobility of vessels can create the chances of end-to-end communication. The mobility pattern of vessel is one of the key metrics on ocean MDTN network. Because of the high cost, few experiments have focused on research of vessel mobility pattern for the moment. In this paper, we study the traces of more than 4000 fishing and freight vessels. Firstly, to solve the data noise and sparsity problem, we design two algorithms to filter the noise and complement the missing data based on the vessel's turning feature. Secondly, after studying the traces of vessels, we observe that the vessel's traces are confined by invisible boundary. Thirdly, through defining the distance between traces, we design MR-Similarity algorithm to find the mobility pattern of vessels. Finally, we realize our algorithm on cluster and evaluate the performance and accuracy. Our results can provide the guidelines on design of data routing protocols on ocean MDTN.

  19. Review of analysis methods for prestressed concrete reactor vessels

    International Nuclear Information System (INIS)

    Dodge, W.G.; Bazant, Z.P.; Gallagher, R.H.

    1977-02-01

    Theoretical and practical aspects of analytical models and numerical procedures for detailed analysis of prestressed concrete reactor vessels are reviewed. Constitutive models and numerical algorithms for time-dependent and nonlinear response of concrete and various methods for modeling crack propagation are discussed. Published comparisons between experimental and theoretical results are used to assess the accuracy of these analytical methods

  20. Greatest Happiness Principle in a Complex System Approach

    Directory of Open Access Journals (Sweden)

    Katalin Martinás

    2012-06-01

    Full Text Available The principle of greatest happiness was the basis of ethics in Plato’s and Aristotle’s work, it served as the basis of utility principle in economics, and the happiness research has become a hot topic in social sciences in Western countries in particular in economics recently. Nevertheless there is a considerable scientific pessimism over whether it is even possible to affect sustainable increases in happiness.In this paper we outline an economic theory of decision based on the greatest happiness principle (GHP. Modern equilibrium economics is a simple system simplification of the GHP, the complex approach outlines a non-equilibrium economic theory. The comparison of the approaches reveals the fact that the part of the results – laws of modern economics – follow from the simplifications and they are against the economic nature. The most important consequence is that within the free market economy one cannot be sure that the path found by it leads to a beneficial economic system.

  1. Midland reactor pressure vessel flaw distribution

    International Nuclear Information System (INIS)

    Foulds, J.R.; Kennedy, E.L.; Rosinski, S.T.

    1993-12-01

    The results of laboratory nondestructive examination (NDE), and destructive cross-sectioning of selected weldment sections of the Midland reactor pressure vessel were analyzed per a previously developed methodology in order to develop a flaw distribution. The flaw distributions developed from the NDE results obtained by two different ultrasonic test (UT) inspections (Electric Power Research Institute NDE Center and Pacific Northwest Laboratories) were not statistically significantly different. However, the distribution developed from the NDE Center's (destructive) cross-sectioning-based data was found to be significantly different than those obtained through the UT inspections. A fracture mechanics-based comparison of the flaw distributions showed that the cross-sectioning-based data, conservatively interpreted (all defects considered as flaws), gave a significantly lower vessel failure probability when compared with the failure probability values obtained using the UT-based distributions. Given that the cross-sectioning data were reportedly biased toward larger, more significant-appearing (by UT) indications, it is concluded that the nondestructive examinations produced definitively conservative results. In addition to the Midland vessel inspection-related analyses, a set of twenty-seven numerical simulations, designed to provide a preliminary quantitative assessment of the accuracy of the flaw distribution method used here, were conducted. The calculations showed that, in more than half the cases, the analysis produced reasonably accurate predictions

  2. Stresses in transition region of VVER-1000 reactor vessels

    International Nuclear Information System (INIS)

    Namgung, I.; Nguye, T.L.

    2014-01-01

    Most of the western PWR reactor's bottom head is hemi-spherical shape, however for Russian designed VVER family of reactor it is ellipsoidal shape. The transition region from shell side to ellipsoidal head and transition top flange to cylindrical shell develop higher stress concentration than western PWR reactor vessel. This region can be modeled as conical shell with varying thickness. The theoretical derivation of stress in the thick-walled conical cylinder with varying thickness was developed and shown in detail. The results is applied to VVER-1000 reactor vessel of which shell to bottom ellipsoidal shell and shell to upper flange were investigated for stress field. The theoretical calculations were also compared with FEM solutions. An axisymmetric 3D model of VVER-1000 reactor vessel (without closure head) FEM model was created and internal hydrostatic pressure boundary condition was applied. The stress results from FEM and theoretical calculation were compared, and the discrepancies and accuracies of the theoretical results were discussed. (author)

  3. Stresses in transition region of VVER-1000 reactor vessels

    Energy Technology Data Exchange (ETDEWEB)

    Namgung, I. [KEPCO International Nuclear Graduate School, Ulsan (Korea, Republic of); Nguye, T.L. [KEPCO International Nuclear Graduate School, Ulsan (Korea, Republic of); National Research Inst. of Mechanical Engineering, Hanoi City, Vietnam (China)

    2014-07-01

    Most of the western PWR reactor's bottom head is hemi-spherical shape, however for Russian designed VVER family of reactor it is ellipsoidal shape. The transition region from shell side to ellipsoidal head and transition top flange to cylindrical shell develop higher stress concentration than western PWR reactor vessel. This region can be modeled as conical shell with varying thickness. The theoretical derivation of stress in the thick-walled conical cylinder with varying thickness was developed and shown in detail. The results is applied to VVER-1000 reactor vessel of which shell to bottom ellipsoidal shell and shell to upper flange were investigated for stress field. The theoretical calculations were also compared with FEM solutions. An axisymmetric 3D model of VVER-1000 reactor vessel (without closure head) FEM model was created and internal hydrostatic pressure boundary condition was applied. The stress results from FEM and theoretical calculation were compared, and the discrepancies and accuracies of the theoretical results were discussed. (author)

  4. Effects of temperature on corrosion fatigue crack growth of pressure vessel steels in PWR coolant

    International Nuclear Information System (INIS)

    Tice, D.R.; Bramwell, I.L.; Fairbrother, H.; Worswick, D.

    1994-01-01

    This paper presents experimental results concerning crack propagation rates in A508-III pressure vessel steel (medium sulphur content) exposed to PWR primary water at temperatures between 130 and 290 C. The results indicate that the greatest increase in corrosion fatigue crack growth rate occurs at temperatures in the range 150 to 200 C. Under these conditions, there was a marked change in the appearance of the fracture surface, with extensive micro-branching of the crack front and occasional bifurcation of the whole crack path. In contrast, at 290 C, the fracture surface is smoother, similar to that due to inert fatigue. The implication of these observations for assessment of the pressure vessel integrity, is examined. 14 refs., 15 figs., 3 tabs

  5. Developments of high-performance moderator vessel for JRR-3 cold neutron source

    International Nuclear Information System (INIS)

    Arai, Masaji; Tamura, Itaru; Hazawa, Tomoya

    2015-05-01

    The cold neutron source (CNS) facility converts thermal neutrons into cold neutrons to moderate neutrons with liquid hydrogen. The cold neutron beam at Japan Research Reactor No. 3 (JRR-3) is led to the beam experimental devices in the beam hall through neutron guide tubes. High intensities of the cold neutron beam are always demanded for increasing the experimental effectiveness and accuracy. In the Department of Research Reactor and Tandem Accelerator, developments of high-performance CNS moderator vessel that can produce cold neutron intensity about two times higher compared to the existing vessel have been performed in the second medium term plans. We compiled this report about the technological development to solve several problems with the design and manufacture of new vessel. In the present study, design strength evaluation, mockup test, simulation for thermo-fluid dynamics of the liquid hydrogen and strength evaluation of the different-material-bonding were studied. By these evaluation results, we verified that the developed new vessel can be applied to CNS moderator vessel of JRR-3. (author)

  6. A thresholding based technique to extract retinal blood vessels from fundus images

    Directory of Open Access Journals (Sweden)

    Jyotiprava Dash

    2017-12-01

    Full Text Available Retinal imaging has become the significant tool among all the medical imaging technology, due to its capability to extract many data which is linked to various eye diseases. So, the accurate extraction of blood vessel is necessary that helps the eye care specialists and ophthalmologist to identify the diseases at the early stages. In this paper, we have proposed a computerized technique for extraction of blood vessels from fundus images. The process is conducted in three phases: (i pre-processing where the image is enhanced using contrast limited adaptive histogram equalization and median filter, (ii segmentation using mean-C thresholding to extract retinal blood vessels, (iii post-processing where morphological cleaning operation is used to remove isolated pixels. The performance of the proposed method is tested on and experimental results show that our method achieve an accuracies of 0.955 and 0.954 on Digital retinal images for vessel extraction (DRIVE and Child heart and health study in England (CHASE_DB1 databases respectively.

  7. Use of sentinel-1 data for vessel detection in South African oceans: Early results

    CSIR Research Space (South Africa)

    Kleynhans, Waldo

    2015-08-01

    Full Text Available taking into consideration local incident angles. Early experimental results show promising vessel detection accuracy using the Sentinel-1 data but that polarization and incidence angle are important parameters to take into consideration when working...

  8. Primo vessel inside a lymph vessel emerging from a cancer tissue.

    Science.gov (United States)

    Lee, Sungwoo; Ryu, Yeonhee; Cha, Jinmyung; Lee, Jin-Kyu; Soh, Kwang-Sup; Kim, Sungchul; Lim, Jaekwan

    2012-10-01

    Primo vessels were observed inside the lymph vessels near the caudal vena cava of a rabbit and a rat and in the thoracic lymph duct of a mouse. In the current work we found a primo vessel inside the lymph vessel that came out from the tumor tissue of a mouse. A cancer model of a nude mouse was made with human lung cancer cell line NCI-H460. We injected fluorescent nanoparticles into the xenografted tumor tissue and studied their flow in blood, lymph, and primo vessels. Fluorescent nanoparticles flowed through the blood vessels quickly in few minutes, and but slowly in the lymph vessels. The bright fluorescent signals of nanoparticles disappeared within one hour in the blood vessels but remained much longer up to several hours in the case of lymph vessels. We found an exceptional case of lymph vessels that remained bright with fluorescence up to 24 hours. After detailed examination we found that the bright fluorescence was due to a putative primo vessel inside the lymph vessel. This rare observation is consistent with Bong-Han Kim's claim on the presence of a primo vascular system in lymph vessels. It provides a significant suggestion on the cancer metastasis through primo vessels and lymph vessels. Copyright © 2012. Published by Elsevier B.V.

  9. The impact of 18F-FDG PET on the management of patients with suspected large vessel vasculitis

    International Nuclear Information System (INIS)

    Fuchs, Martin; Rasch, Helmut; Berg, Scott; Ng, Quinn K.T.; Mueller-Brand, Jan; Walter, Martin A.; Briel, Matthias; Daikeler, Thomas; Tyndall, Alan; Walker, Ulrich A.; Raatz, Heike; Jayne, David; Koetter, Ina; Blockmans, Daniel; Cid, Maria C.; Prieto-Gonzalez, Sergio; Lamprecht, Peter; Salvarani, Carlo; Karageorgaki, Zaharenia; Watts, Richard; Luqmani, Raashid

    2012-01-01

    We aimed to assess the impact of 18 F-fluorodeoxyglucose (FDG) positron emission tomography (PET) on the management of patients with suspected large vessel vasculitis. An international expert panel determined diagnoses and clinical management in patients with suspected large vessel vasculitis, with and without the results of 18 F-FDG PET, respectively. The accuracy of the clinical diagnosis and the resulting clinical management with and without the 18 F-FDG PET results were compared using logistic regression models. The analysis included 30 patients referred to a tertiary care centre with large vessel vasculitis and 31 controls. 18 F-FDG PET had an overall sensitivity of 73.3% [95% confidence interval (CI) 54.1-87.7%], a specificity of 83.9% (95% CI 66.3-94.5%), a positive predictive value of 81.5% (95% CI 61.9-93.7%) and a negative predictive value of 76.5% (95% CI 58.8-89.3%). The diagnostic accuracy of 18 F-FDG PET was higher in patients not receiving immunosuppressive drugs (93.3 vs 64.5%, p = 0.006). Taken in context with other available diagnostic modalities, the addition of 18 F-FDG PET increased the clinical diagnostic accuracy from 54.1 to 70.5% (p = 0.04). The addition of 18 F-FDG PET increased the number of indicated biopsies from 22 of 61 patients (36.1%) to 25 of 61 patients (41.0%) and changed the treatment recommendation in 8 of 30 patients (26.7%) not receiving immunosuppressive medication and in 7 of 31 patients (22.6%) receiving immunosuppressive medication. 18 F-FDG PET is a sensitive and specific imaging tool for large vessel vasculitis, especially when performed in patients not receiving immunosuppressive drugs. It increases the overall diagnostic accuracy and has an impact on the clinical management in a significant proportion of patients. (orig.)

  10. Quality assurance experience in the manufacture of PFBR reactor vessel during technology development work

    International Nuclear Information System (INIS)

    Shanmugam, K.; Chandramohan, R.; Ramamurthy, M.K.

    1996-01-01

    An efficient and proper implementation of quality assurance in the technology development works of Prototype Fast Breeder Reactor (PFBR) main vessel was undertaken to achieve the desired quality and dimensional accuracy of main vessel. In this paper an attempt has been made to bring out the methods and procedures adopted to implement the quality assurance programme on important activities including approval of documents, material, general requirements for manufacture of SS components, inspection procedures, forming and welding of petals, non-destructive testing etc. (author)

  11. Automated artery-venous classification of retinal blood vessels based on structural mapping method

    Science.gov (United States)

    Joshi, Vinayak S.; Garvin, Mona K.; Reinhardt, Joseph M.; Abramoff, Michael D.

    2012-03-01

    Retinal blood vessels show morphologic modifications in response to various retinopathies. However, the specific responses exhibited by arteries and veins may provide a precise diagnostic information, i.e., a diabetic retinopathy may be detected more accurately with the venous dilatation instead of average vessel dilatation. In order to analyze the vessel type specific morphologic modifications, the classification of a vessel network into arteries and veins is required. We previously described a method for identification and separation of retinal vessel trees; i.e. structural mapping. Therefore, we propose the artery-venous classification based on structural mapping and identification of color properties prominent to the vessel types. The mean and standard deviation of each of green channel intensity and hue channel intensity are analyzed in a region of interest around each centerline pixel of a vessel. Using the vector of color properties extracted from each centerline pixel, it is classified into one of the two clusters (artery and vein), obtained by the fuzzy-C-means clustering. According to the proportion of clustered centerline pixels in a particular vessel, and utilizing the artery-venous crossing property of retinal vessels, each vessel is assigned a label of an artery or a vein. The classification results are compared with the manually annotated ground truth (gold standard). We applied the proposed method to a dataset of 15 retinal color fundus images resulting in an accuracy of 88.28% correctly classified vessel pixels. The automated classification results match well with the gold standard suggesting its potential in artery-venous classification and the respective morphology analysis.

  12. An approach to localize the retinal blood vessels using bit planes and centerline detection.

    Science.gov (United States)

    Fraz, M M; Barman, S A; Remagnino, P; Hoppe, A; Basit, A; Uyyanonvara, B; Rudnicka, A R; Owen, C G

    2012-11-01

    The change in morphology, diameter, branching pattern or tortuosity of retinal blood vessels is an important indicator of various clinical disorders of the eye and the body. This paper reports an automated method for segmentation of blood vessels in retinal images. A unique combination of techniques for vessel centerlines detection and morphological bit plane slicing is presented to extract the blood vessel tree from the retinal images. The centerlines are extracted by using the first order derivative of a Gaussian filter in four orientations and then evaluation of derivative signs and average derivative values is performed. Mathematical morphology has emerged as a proficient technique for quantifying the blood vessels in the retina. The shape and orientation map of blood vessels is obtained by applying a multidirectional morphological top-hat operator with a linear structuring element followed by bit plane slicing of the vessel enhanced grayscale image. The centerlines are combined with these maps to obtain the segmented vessel tree. The methodology is tested on three publicly available databases DRIVE, STARE and MESSIDOR. The results demonstrate that the performance of the proposed algorithm is comparable with state of the art techniques in terms of accuracy, sensitivity and specificity. Copyright © 2011 Elsevier Ireland Ltd. All rights reserved.

  13. Hepatic vessel segmentation for 3D planning of liver surgery experimental evaluation of a new fully automatic algorithm.

    Science.gov (United States)

    Conversano, Francesco; Franchini, Roberto; Demitri, Christian; Massoptier, Laurent; Montagna, Francesco; Maffezzoli, Alfonso; Malvasi, Antonio; Casciaro, Sergio

    2011-04-01

    The aim of this study was to identify the optimal parameter configuration of a new algorithm for fully automatic segmentation of hepatic vessels, evaluating its accuracy in view of its use in a computer system for three-dimensional (3D) planning of liver surgery. A phantom reproduction of a human liver with vessels up to the fourth subsegment order, corresponding to a minimum diameter of 0.2 mm, was realized through stereolithography, exploiting a 3D model derived from a real human computed tomographic data set. Algorithm parameter configuration was experimentally optimized, and the maximum achievable segmentation accuracy was quantified for both single two-dimensional slices and 3D reconstruction of the vessel network, through an analytic comparison of the automatic segmentation performed on contrast-enhanced computed tomographic phantom images with actual model features. The optimal algorithm configuration resulted in a vessel detection sensitivity of 100% for vessels > 1 mm in diameter, 50% in the range 0.5 to 1 mm, and 14% in the range 0.2 to 0.5 mm. An average area overlap of 94.9% was obtained between automatically and manually segmented vessel sections, with an average difference of 0.06 mm(2). The average values of corresponding false-positive and false-negative ratios were 7.7% and 2.3%, respectively. A robust and accurate algorithm for automatic extraction of the hepatic vessel tree from contrast-enhanced computed tomographic volume images was proposed and experimentally assessed on a liver model, showing unprecedented sensitivity in vessel delineation. This automatic segmentation algorithm is promising for supporting liver surgery planning and for guiding intraoperative resections. Copyright © 2011 AUR. Published by Elsevier Inc. All rights reserved.

  14. Accuracy of a novel photoacoustic-based approach to surgical guidance performed with and without a da Vinci robot

    Science.gov (United States)

    Gandhi, Neeraj; Kim, Sungmin; Kazanzides, Peter; Lediju Bell, Muyinatu A.

    2017-03-01

    Minimally invasive surgery carries the deadly risk of rupturing major blood vessels, such as the internal carotid arteries hidden by bone in endonasal transsphenoidal surgery. We propose a novel approach to surgical guidance that relies on photoacoustic-based vessel separation measurements to assess the extent of safety zones during these type of surgical procedures. This approach can be implemented with or without a robot or navigation system. To determine the accuracy of this approach, a custom phantom was designed and manufactured for modular placement of two 3.18-mm diameter vessel-mimicking targets separated by 10-20 mm. Photoacoustic images were acquired as the optical fiber was swept across the vessels in the absence and presence of teleoperation with a research da Vinci Surgical System. When the da Vinci was used, vessel positions were recorded based on the fiber position (calculated from the robot kinematics) that corresponded to an observed photoacoustic signal. In all cases, compounded photoacoustic data from a single sweep displayed the four vessel boundaries in one image. Amplitude- and coherence-based photoacoustic images were used to estimate vessel separations, resulting in 0.52-0.56 mm mean absolute errors, 0.66-0.71 mm root mean square errors, and 65-68% more accuracy compared to fiber position measurements obtained through the da Vinci robot kinematics. Results indicate that with further development, photoacoustic image-based measurements of anatomical landmarks could be a viable method for real-time path planning in multiple interventional photoacoustic applications.

  15. Implicit vessel surface reconstruction for visualization and CFD simulation

    International Nuclear Information System (INIS)

    Schumann, Christian; Peitgen, Heinz-Otto; Neugebauer, Mathias; Bade, Ragnar; Preim, Bernhard

    2008-01-01

    Accurate and high-quality reconstructions of vascular structures are essential for vascular disease diagnosis and blood flow simulations.These applications necessitate a trade-off between accuracy and smoothness. An additional requirement for the volume grid generation for Computational Fluid Dynamics (CFD) simulations is a high triangle quality. We propose a method that produces an accurate reconstruction of the vessel surface with satisfactory surface quality. A point cloud representing the vascular boundary is generated based on a segmentation result. Thin vessels are subsampled to enable an accurate reconstruction. A signed distance field is generated using Multi-level Partition of Unity Implicits and subsequently polygonized using a surface tracking approach. To guarantee a high triangle quality, the surface is remeshed. Compared to other methods, our approach represents a good trade-off between accuracy and smoothness. For the tested data, the average surface deviation to the segmentation results is 0.19 voxel diagonals and the maximum equi-angle skewness values are below 0.75. The generated surfaces are considerably more accurate than those obtained using model-based approaches. Compared to other model-free approaches, the proposed method produces smoother results and thus better supports the perception and interpretation of the vascular topology. Moreover, the triangle quality of the generated surfaces is suitable for CFD simulations. (orig.)

  16. Qualification of UT methods and systems used for in-service inspections of VVER 440 vessels

    International Nuclear Information System (INIS)

    Skala, Z.; Vit, J.

    2003-01-01

    SKODA JS has been performing automated in-service inspections VVER reactor pressure vessels for more than twenty years. All of these inspections were performed by ultrasonic pulse echo method, combined from 1996 with eddy current testing. The Time of Flight Diffraction Method (TOFD) is one of modern methods of ultrasonic testing. The accuracy of sizing the through wall extent of a flaw by TOFD is much better than the accuracy achievable by the pulse echo method. A series of laboratory tests were performed by SKODA JS and confirmed the suitability of TOFD method for VVER reactor parts testing. The Czech Atomic law demands the qualification of systems and methods used for the in-service inspections of nuclear reactors. The qualification is done in accordance with ENIQ methodology and consists of preparation of the Technical Justification and practical tests made under the surveillance of Qualification Body. SKODA JS intends to qualify systems and methods used for the automated ultrasonic testing of VVER 440 and VVER 1000 reactor components from the inner as well as from the outer surface. The accuracy of the flaw through wall extent sizing by TOFD was confirmed by the qualification of methods and systems used for the testing of VVER 440 vessel circumferential weld and so the TOFD method shall be used routinely by SKODA JS for the inspection of vessel circumferential welds root area and for sizing of flaws exceeding the acceptance level. (author)

  17. Captopril improves tumor nanomedicine delivery by increasing tumor blood perfusion and enlarging endothelial gaps in tumor blood vessels.

    Science.gov (United States)

    Zhang, Bo; Jiang, Ting; Tuo, Yanyan; Jin, Kai; Luo, Zimiao; Shi, Wei; Mei, Heng; Hu, Yu; Pang, Zhiqing; Jiang, Xinguo

    2017-12-01

    Poor tumor perfusion and unfavorable vessel permeability compromise nanomedicine drug delivery to tumors. Captopril dilates blood vessels, reducing blood pressure clinically and bradykinin, as the downstream signaling moiety of captopril, is capable of dilating blood vessels and effectively increasing vessel permeability. The hypothesis behind this study was that captopril can dilate tumor blood vessels, improving tumor perfusion and simultaneously enlarge the endothelial gaps of tumor vessels, therefore enhancing nanomedicine drug delivery for tumor therapy. Using the U87 tumor xenograft with abundant blood vessels as the tumor model, tumor perfusion experiments were carried out using laser Doppler imaging and lectin-labeling experiments. A single treatment of captopril at a dose of 100 mg/kg significantly increased the percentage of functional vessels in tumor tissues and improved tumor blood perfusion. Scanning electron microscopy of tumor vessels also indicated that the endothelial gaps of tumor vessels were enlarged after captopril treatment. Immunofluorescence-staining of tumor slices demonstrated that captopril significantly increased bradykinin expression, possibly explaining tumor perfusion improvements and endothelial gap enlargement. Additionally, imaging in vivo, imaging ex vivo and nanoparticle distribution in tumor slices indicated that after a single treatment with captopril, the accumulation of 115-nm nanoparticles in tumors had increased 2.81-fold with a more homogeneous distribution pattern in comparison to non-captopril treated controls. Finally, pharmacodynamics experiments demonstrated that captopril combined with paclitaxel-loaded nanoparticles resulted in the greatest tumor shrinkage and the most extensive necrosis in tumor tissues among all treatment groups. Taken together, the data from the present study suggest a novel strategy for improving tumor perfusion and enlarging blood vessel permeability simultaneously in order to improve

  18. Analyses of Trawling Track and Fishing Activity Based on the Data of Vessel Monitoring System (VMS):A Case Study of the Single Otter Trawl Vessels in the Zhoushan Fishing Ground

    Institute of Scientific and Technical Information of China (English)

    WANG Yang; WANG Yingbin; ZHENG Ji

    2015-01-01

    The original purpose of Vessel Monitoring System (VMS) is for enforcement and control of vessel sailing. With the ap-plication of VMS in fishing vessels, more and more population dynamic studies have used VMS data to improve the accuracy of fisheries stock assessment. In this paper, we simulated the trawl trajectory under different time intervals using the cubic Hermite spline (cHs) interpolation method based on the VMS data of 8 single otter trawl vessels (totally 36000 data items) fishing in Zhou-shan fishing ground from September 2012 to December 2012, and selected the appropriate time interval. We then determined vessels’ activities (fishing or non-fishing) by comparing VMS speed data with the corresponding speeds from logbooks. The results showed that the error of simulated trajectory greatly increased with the increase of time intervals of VMS data when they were longer than 30 minutes. Comparing the speeds from VMS with those from the corresponding logbooks, we found that the vessels’ speeds were be-tween 2.5kn and 5.0kn in fishing. The cHs interpolation method is a new choice for improving the accuracy of estimation of sailing trajectory, and the VMS can be used to determine the vessels’ activities with the analysis of their trajectories and speeds. Therefore, when the fishery information is limited, VMS can be one of the important data sources for fisheries stock assessment, and more at-tention should be paid to its construction and application to fisheries stock assessment and management.

  19. Evaluation for In-Vessel Retention Capabilities with In-Vessel Injection and External Reactor Vessel Cooling

    International Nuclear Information System (INIS)

    Lee, Jeong Seong; Ryu, In Chul; Moon, Young Tae

    2016-01-01

    If the accident has not progressed to the point of substantial changes in the core geometry, establishing adequate cooling is as straightforward as re-establishing flow through the reactor core. However, if the accident has progressed to the point where the core geometry is substantially altered as a result of material melting and relocation, as was the case in the TMI-2 accident, the means of cooling the debris are not as straightforward. From this time on, the reactor core was either completely or nearly covered by water, with high pressure injection flow initiated shortly after three hours into the accident. However, the core debris was not coolable in this configuration and a substantial quantity of molten core material drained into the bypass region, with approximately twenty metric tons of molten debris draining into the reactor pressure vessel (RPV) lower head. Hence, the core configuration developed at approximately three hours into the accident was not coolable, even submerged in water. The purpose of this paper is to evaluate in-vessel retention capabilities with in-vessel injection (IVI) and external reactor vessel cooling (ERVC) available in a reactor application by using the integrated severe accident analysis code. The MAAP5 models were improved to facilitate evaluation of the in-vessel retention capability of APR1400. In-vessel retention capabilities have been analyzed for the APR1400 using the MAAP5.03 code. The results show that in-vessel retention is feasible when in-vessel injection is initiated within a relatively short time frame under the simulation condition used in the present study

  20. Evaluation for In-Vessel Retention Capabilities with In-Vessel Injection and External Reactor Vessel Cooling

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Jeong Seong; Ryu, In Chul; Moon, Young Tae [KEPCO Engineering and Construction Co. Ltd., Deajeon (Korea, Republic of)

    2016-10-15

    If the accident has not progressed to the point of substantial changes in the core geometry, establishing adequate cooling is as straightforward as re-establishing flow through the reactor core. However, if the accident has progressed to the point where the core geometry is substantially altered as a result of material melting and relocation, as was the case in the TMI-2 accident, the means of cooling the debris are not as straightforward. From this time on, the reactor core was either completely or nearly covered by water, with high pressure injection flow initiated shortly after three hours into the accident. However, the core debris was not coolable in this configuration and a substantial quantity of molten core material drained into the bypass region, with approximately twenty metric tons of molten debris draining into the reactor pressure vessel (RPV) lower head. Hence, the core configuration developed at approximately three hours into the accident was not coolable, even submerged in water. The purpose of this paper is to evaluate in-vessel retention capabilities with in-vessel injection (IVI) and external reactor vessel cooling (ERVC) available in a reactor application by using the integrated severe accident analysis code. The MAAP5 models were improved to facilitate evaluation of the in-vessel retention capability of APR1400. In-vessel retention capabilities have been analyzed for the APR1400 using the MAAP5.03 code. The results show that in-vessel retention is feasible when in-vessel injection is initiated within a relatively short time frame under the simulation condition used in the present study.

  1. Comparison of vacuum rise time, vacuum limit accuracy, and occlusion break surge of 3 new phacoemulsification systems.

    Science.gov (United States)

    Han, Young Keun; Miller, Kevin M

    2009-08-01

    To compare vacuum rise time, vacuum limit accuracy, and occlusion break surge of 3 new phacoemulsification machines. Jules Stein Eye Institute and Department of Ophthalmology, David Geffen School of Medicine at UCLA, Los Angeles, California, USA. The vacuum rise time under normal and enhanced aspiration modes, vacuum limit accuracy, and occlusion break surge of the Infiniti Vision System, Stellaris Vision Enhancement System, and WhiteStar Signature Phacoemulsification System were tested. Vacuum rise time and limit accuracy were measured at limit settings of 400 mm Hg and 600 mm Hg. Surge area was recorded at vacuum limit settings of 200 mm Hg, 300 mm Hg, 400 mm Hg, and 500 mm Hg. The Infiniti had the fastest vacuum rise times under normal and enhanced aspiration modes. At 4 seconds, the vacuum limit accuracy was greatest with the Infiniti at the 400 mm Hg limit and the Signature at the 600 mm Hg limit. The Stellaris did not reach either vacuum target. The Infiniti performed better than the other 2 machines during testing of occlusion break surge at all vacuum limit settings above 200 mm Hg. Under controlled laboratory test conditions, the Infiniti had the fastest vacuum rise time, greatest vacuum limit accuracy at 400 mm Hg, and least occlusion break surge. These results can be explained by the lower compliance of the Infiniti system.

  2. Forging technology for large nuclear pressure vessel parts

    International Nuclear Information System (INIS)

    Kakimoto, Hideki; Ikegami, Tomonori

    2014-01-01

    The increasing output of nuclear power generation calls for larger vessels for next-generation nuclear power plants. A vessel with an increased diameter requires increased load for its forging, which can make it difficult to use a conventional solid die. In order to reduce the forging load, a rotary incremental forging method has been applied to hot forging. This method includes pressing and rotating a material in an incremental manner such that a target shape is obtained. This study aimed at improving the accuracy of numerical simulation for the rotary incremental forging to reduce the load when forging large vessels. This has enabled the temperature of the material and flow stress to be precisely predicted; an example of this is reported in the paper. Specifically, the heat transfer coefficient to be used for the numerical simulation had been determined experimentally from a small-scale hot-forging. The reduction of the flow stress associated with incremental forging, had been deduced from a compression test, and the value was applied to the numerical simulation. A preform was designed on the basis of the above simulation to perform a 1/1 size scale experiment. A precision of better than 5% has been confirmed for the shape prediction. (author)

  3. Multiple shell pressure vessel

    International Nuclear Information System (INIS)

    Wedellsborg, B.W.

    1988-01-01

    A method is described of fabricating a pressure vessel comprising the steps of: attaching a first inner pressure vessel having means defining inlet and outlet openings to a top flange, placing a second inner pressure vessel, having means defining inlet and outlet opening, concentric with and spaced about the first inner pressure vessel and attaching the second inner pressure vessel to the top flange, placing an outer pressure vessel, having inlet and outlet openings, concentric with and spaced apart about the second inner pressure vessel and attaching the outer pressure vessel to the top flange, attaching a generally cylindrical inner inlet conduit and a generally cylindrical inner outlet conduit respectively to the inlet and outlet openings in the first inner pressure vessel, attaching a generally cylindrical outer inlet conduit and a generally cylindrical outer outlet conduit respectively to the inlet and outlet opening in the second inner pressure vessel, heating the assembled pressure vessel to a temperature above the melting point of a material selected from the group, lead, tin, antimony, bismuth, potassium, sodium, boron and mixtures thereof, filling the space between the first inner pressure vessel and the second inner pressure vessel with material selected from the group, filling the space between the second inner pressure vessel and the outer pressure vessel with material selected from the group, and pressurizing the material filling the spaces between the pressure vessels to a predetermined pressure, the step comprising: pressurizing the spaces to a pressure whereby the wall of the first inner pressure vessel is maintained in compression during steady state operation of the pressure vessel

  4. 33 CFR 90.3 - Pushing vessel and vessel being pushed: Composite unit.

    Science.gov (United States)

    2010-07-01

    ... 33 Navigation and Navigable Waters 1 2010-07-01 2010-07-01 false Pushing vessel and vessel being... HOMELAND SECURITY INLAND NAVIGATION RULES INLAND RULES: INTERPRETATIVE RULES § 90.3 Pushing vessel and vessel being pushed: Composite unit. Rule 24(b) of the Inland Rules states that when a pushing vessel and...

  5. 33 CFR 82.3 - Pushing vessel and vessel being pushed: Composite unit.

    Science.gov (United States)

    2010-07-01

    ... 33 Navigation and Navigable Waters 1 2010-07-01 2010-07-01 false Pushing vessel and vessel being... HOMELAND SECURITY INTERNATIONAL NAVIGATION RULES 72 COLREGS: INTERPRETATIVE RULES § 82.3 Pushing vessel and vessel being pushed: Composite unit. Rule 24(b) of the 72 COLREGS states that when a pushing vessel and a...

  6. Dynamic Positioning Capability Analysis for Marine Vessels Based on A DPCap Polar Plot Program

    Science.gov (United States)

    Wang, Lei; Yang, Jian-min; Xu, Sheng-wen

    2018-03-01

    Dynamic positioning capability (DPCap) analysis is essential in the selection of thrusters, in their configuration, and during preliminary investigation of the positioning ability of a newly designed vessel dynamic positioning system. DPCap analysis can help determine the maximum environmental forces, in which the DP system can counteract in given headings. The accuracy of the DPCap analysis is determined by the precise estimation of the environmental forces as well as the effectiveness of the thrust allocation logic. This paper is dedicated to developing an effective and efficient software program for the DPCap analysis for marine vessels. Estimation of the environmental forces can be obtained by model tests, hydrodynamic computation and empirical formulas. A quadratic programming method is adopted to allocate the total thrust on every thruster of the vessel. A detailed description of the thrust allocation logic of the software program is given. The effectiveness of the new program DPCap Polar Plot (DPCPP) was validated by a DPCap analysis for a supply vessel. The present study indicates that the developed program can be used in the DPCap analysis for marine vessels. Moreover, DPCap analysis considering the thruster failure mode might give guidance to the designers of vessels whose thrusters need to be safer.

  7. The impact of {sup 18}F-FDG PET on the management of patients with suspected large vessel vasculitis

    Energy Technology Data Exchange (ETDEWEB)

    Fuchs, Martin; Rasch, Helmut; Berg, Scott; Ng, Quinn K.T.; Mueller-Brand, Jan; Walter, Martin A. [University Hospital, Institute of Nuclear Medicine, Basel (Switzerland); Briel, Matthias [University Hospital Basel, Institute for Clinical Epidemiology and Biostatistics, Basel (Switzerland); McMaster University, Department of Clinical Epidemiology and Biostatistics, Hamilton, ON (Canada); Daikeler, Thomas; Tyndall, Alan [University Hospital Basel, Department of Rheumatology, Basel (Switzerland); Walker, Ulrich A. [Felix Platter Spital, Department of Rheumatology of Basle University, Basel (Switzerland); Raatz, Heike [University Hospital Basel, Institute for Clinical Epidemiology and Biostatistics, Basel (Switzerland); Jayne, David [Addenbrooke' s Hospital, Vasculitis and Lupus Unit, Cambridge (United Kingdom); Koetter, Ina [University Hospital Tuebingen, Department of Internal Medicine II, Tuebingen (Germany); Blockmans, Daniel [University Hospital Gasthuisberg, Department of General Internal Medicine, Leuven (Belgium); Cid, Maria C.; Prieto-Gonzalez, Sergio [Hospital Clinic, University of Barcelona, IDIBAPS, Department of Systemic Autoimmune Diseases, 08036-Barcelona (Spain); Lamprecht, Peter [University Hospital of Schleswig-Holstein, Department of Rheumatology, Luebeck (Germany); Salvarani, Carlo [Arcispedale S. Maria Nuova, Department of Rheumatology, Reggio Emilia (Italy); Karageorgaki, Zaharenia [Agios Dimitrios General Hospital, 1st Department of Internal Medicine, Thessaloniki (Greece); Watts, Richard [University of East Anglia, Norwich Medical School, Norwich (United Kingdom); Ipswich Hospital NHS Trust, Ipswich (United Kingdom); Luqmani, Raashid [Nuffield Orthopaedic Centre, Department of Rheumatology, Oxford (United Kingdom)

    2012-02-15

    We aimed to assess the impact of {sup 18}F-fluorodeoxyglucose (FDG) positron emission tomography (PET) on the management of patients with suspected large vessel vasculitis. An international expert panel determined diagnoses and clinical management in patients with suspected large vessel vasculitis, with and without the results of {sup 18}F-FDG PET, respectively. The accuracy of the clinical diagnosis and the resulting clinical management with and without the {sup 18}F-FDG PET results were compared using logistic regression models. The analysis included 30 patients referred to a tertiary care centre with large vessel vasculitis and 31 controls. {sup 18}F-FDG PET had an overall sensitivity of 73.3% [95% confidence interval (CI) 54.1-87.7%], a specificity of 83.9% (95% CI 66.3-94.5%), a positive predictive value of 81.5% (95% CI 61.9-93.7%) and a negative predictive value of 76.5% (95% CI 58.8-89.3%). The diagnostic accuracy of {sup 18}F-FDG PET was higher in patients not receiving immunosuppressive drugs (93.3 vs 64.5%, p = 0.006). Taken in context with other available diagnostic modalities, the addition of {sup 18}F-FDG PET increased the clinical diagnostic accuracy from 54.1 to 70.5% (p = 0.04). The addition of {sup 18}F-FDG PET increased the number of indicated biopsies from 22 of 61 patients (36.1%) to 25 of 61 patients (41.0%) and changed the treatment recommendation in 8 of 30 patients (26.7%) not receiving immunosuppressive medication and in 7 of 31 patients (22.6%) receiving immunosuppressive medication. {sup 18}F-FDG PET is a sensitive and specific imaging tool for large vessel vasculitis, especially when performed in patients not receiving immunosuppressive drugs. It increases the overall diagnostic accuracy and has an impact on the clinical management in a significant proportion of patients. (orig.)

  8. Retinal blood vessel extraction using tunable bandpass filter and fuzzy conditional entropy.

    Science.gov (United States)

    Sil Kar, Sudeshna; Maity, Santi P

    2016-09-01

    Extraction of blood vessels on retinal images plays a significant role for screening of different opthalmologic diseases. However, accurate extraction of the entire and individual type of vessel silhouette from the noisy images with poorly illuminated background is a complicated task. To this aim, an integrated system design platform is suggested in this work for vessel extraction using a sequential bandpass filter followed by fuzzy conditional entropy maximization on matched filter response. At first noise is eliminated from the image under consideration through curvelet based denoising. To include the fine details and the relatively less thick vessel structures, the image is passed through a bank of sequential bandpass filter structure optimized for contrast enhancement. Fuzzy conditional entropy on matched filter response is then maximized to find the set of multiple optimal thresholds to extract the different types of vessel silhouettes from the background. Differential Evolution algorithm is used to determine the optimal gain in bandpass filter and the combination of the fuzzy parameters. Using the multiple thresholds, retinal image is classified as the thick, the medium and the thin vessels including neovascularization. Performance evaluated on different publicly available retinal image databases shows that the proposed method is very efficient in identifying the diverse types of vessels. Proposed method is also efficient in extracting the abnormal and the thin blood vessels in pathological retinal images. The average values of true positive rate, false positive rate and accuracy offered by the method is 76.32%, 1.99% and 96.28%, respectively for the DRIVE database and 72.82%, 2.6% and 96.16%, respectively for the STARE database. Simulation results demonstrate that the proposed method outperforms the existing methods in detecting the various types of vessels and the neovascularization structures. The combination of curvelet transform and tunable bandpass

  9. Vessel Operator System

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Operator cards are required for any operator of a charter/party boat and or a commercial vessel (including carrier and processor vessels) issued a vessel permit from...

  10. Comprehending the structure of a vacuum vessel and in-vessel components of fusion machines. 1. Comprehending the vacuum vessel structure

    International Nuclear Information System (INIS)

    Onozuka, Masanori; Nakahira, Masataka

    2006-01-01

    The functions, conditions and structure of vacuum vessel using tokamak fusion machines are explained. The structural standard and code of vacuum vessel, process of vacuum vessel design, and design of ITER vacuum vessel are described. Production and maintenance of ultra high vacuum, confinement of radioactive materials, support of machines in vessel and electromagnetic force, radiation shield, plasma vertical stability, one-turn electric resistance, high temperature baking heat and remove of nuclear heat, reduce of troidal ripple, structural standard, features of safety of nuclear fusion machines, subjects of structural standard of fusion vacuum vessel, design flow of vacuum vessel, establishment of radial build, selections of materials, baking and cooling method, basic structure, structure of special parts, shield structure, and of support structure, and example of design of structure, ITER, are stated. (S.Y.)

  11. EQUATIONS FOR GAS RELEASING PROCESS FROM PRESSURIZED VESSELS IN ODH EVALUATION

    International Nuclear Information System (INIS)

    JIA, L.X.; WANG, L.

    2001-01-01

    IN THE EVALUATION OF ODH, THE CALCULATION OF THE SPILL RATE FROM THE PRESSURIZED VESSEL IS THE CENTRAL TASK. THE ACCURACY OF THE ENGINEERING ESTIMATION BECOMES ONE OF THE SAFETY DESIGN ISSUES. THIS PAPER SUMMARIZES THE EQUATIONS FOR THE OXYGEN CONCENTRATION CALCULATION IN DIFFERENT CASES, AND DISCUSSES THE EQUATIONS FOR THE GAS RELEASE PROCESS CALCULATION BOTH FOR THE HIGH-PRESSURE GAS TANK AND THE LOW-TEMPERATURE LIQUID CONTAINER

  12. Long Term Validation of High Precision RTK Positioning Onboard a Ferry Vessel Using the MGBAS in the Research Port of Rostock

    Directory of Open Access Journals (Sweden)

    Ralf Ziebold

    2017-09-01

    Full Text Available In order to enable port operations, which require an accuracy of about 10cm, the German Aerospace Center (DLR operates the Maritime Ground Based Augmentation Service (MGBAS in the Research Port of Rostock. The MGBAS reference station provides GPS dual frequency code + phase correction data, which are continuously transmitted via an ultra-high frequency (UHF modem. Up to now the validation of the MGBAS was rather limited. Either a second shore based station was used as an artificial user, or measurement campaigns on a vessel with duration of a few hours have been conducted. In order to overcome this, we have installed three separate dual frequency antennas and receivers and a UHF modem on the Stena Line ferry vessel Mecklenburg-Vorpommern which is plying between Rostock and Trelleborg. This paper concentrates on the analysis of the highly accurate phase based positioning with a Real Time Kinematic (RTK algorithm, using correction data received by the UHF modem onboard the vessel. We analyzed the availability and accuracy of RTK fix solutions for several days, whenever the ferry vessel was inside the service area of the MGBAS.

  13. Conjugate heat transfer analysis for in-vessel retention with external reactor vessel cooling

    International Nuclear Information System (INIS)

    Park, Jong-Woon; Bae, Jae-ho; Song, Hyuk-Jin

    2016-01-01

    Highlights: • A conjugate heat transfer analysis method is applied for in-vessel corium retention. • 3D heat diffusion has a formidable effect in alleviating focusing heat load from metallic layer. • The focusing heat load is decreased by about 2.5 times on the external surface. - Abstract: A conjugate heat transfer analysis method for the thermal integrity of a reactor vessel under external reactor vessel cooling conditions is developed to resolve light metal layer focusing effect issue for in-vessel retention. The method calculates steady-state three-dimensional temperature distribution of a reactor vessel using coupled conjugate heat transfer between in-vessel three-layered stratified corium (metallic pool, oxide pool and heavy metal and polar-angle dependent boiling heat transfer at the outer surface of a reactor vessel). The three-layer corium heat transfer model is utilizing lumped-parameter thermal-resistance circuit method. For the ex-vessel boiling boundary conditions, nucleate, transition and film boiling are considered. The thermal integrity of a reactor vessel is addressed in terms of heat flux at the outer-most nodes of the vessel and remaining thickness profile. The vessel three-dimensional heat conduction is validated against a commercial code. It is found that even though the internal heat flux from the metal layer goes far beyond critical heat flux (CHF) the heat flux from the outermost nodes of the vessel may be maintained below CHF due to massive vessel heat diffusion. The heat diffusion throughout the vessel is more pronounced for relatively low heat generation rate in an oxide pool. Parametric calculations are performed considering thermal conditions such as peak heat flux from a light metal layer, heat generation in an oxide pool and external boiling conditions. The major finding is that the most crucial factor for success of in-vessel retention is not the mass of the molten light metal above the oxide pool but the heat generation rate

  14. Greatest Happiness Principle in a Complex System: Maximisation versus Driving Force

    Directory of Open Access Journals (Sweden)

    Katalin Martinás

    2012-06-01

    Full Text Available From philosophical point of view, micro-founded economic theories depart from the principle of the pursuit of the greatest happiness. From mathematical point of view, micro-founded economic theories depart from the utility maximisation program. Though economists are aware of the serious limitations of the equilibrium analysis, they remain in that framework. We show that the maximisation principle, which implies the equilibrium hypothesis, is responsible for this impasse. We formalise the pursuit of the greatest happiness principle by the help of the driving force postulate: the volumes of activities depend on the expected wealth increase. In that case we can get rid of the equilibrium hypothesis and have new insights into economic theory. For example, in what extent standard economic results depend on the equilibrium hypothesis?

  15. Experimental tests on buckling of ellipsoidal vessel heads subjected to internal pressure

    International Nuclear Information System (INIS)

    Roche, R.L.; Alix, M.

    1980-05-01

    Tests were performed on 17 ellipsoidal vessel heads of three different materials and different geometries. The results include the following: 1) Accurate definition of the geometry and particularly a direct measurement of the thickness along the meridian. 2) The properties of the material of each head, obtained from test specimens cut from the head itself after the test. 3) The recording of deflection/pressure curves with indication of the pressure at which buckling occurred. These results can be used for validation and qualification of methods for calculating the buckling load when plasticity occurs before buckling. It was possible to develop an empirical equation representing the experimental results obtained with satisfactory accuracy. This equation may be useful in pressure vessel design

  16. Xylem resistance to embolism: presenting a simple diagnostic test for the open vessel artefact.

    Science.gov (United States)

    Torres-Ruiz, José M; Cochard, Hervé; Choat, Brendan; Jansen, Steven; López, Rosana; Tomášková, Ivana; Padilla-Díaz, Carmen M; Badel, Eric; Burlett, Regis; King, Andrew; Lenoir, Nicolas; Martin-StPaul, Nicolas K; Delzon, Sylvain

    2017-07-01

    Xylem vulnerability to embolism represents an essential trait for the evaluation of the impact of hydraulics in plant function and ecology. The standard centrifuge technique is widely used for the construction of vulnerability curves, although its accuracy when applied to species with long vessels remains under debate. We developed a simple diagnostic test to determine whether the open-vessel artefact influences centrifuge estimates of embolism resistance. Xylem samples from three species with differing vessel lengths were exposed to less negative xylem pressures via centrifugation than the minimum pressure the sample had previously experienced. Additional calibration was obtained from non-invasive measurement of embolism on intact olive plants by X-ray microtomography. Results showed artefactual decreases in hydraulic conductance (k) for samples with open vessels when exposed to a less negative xylem pressure than the minimum pressure they had previously experienced. X-Ray microtomography indicated that most of the embolism formation in olive occurs at xylem pressures below -4.0 MPa, reaching 50% loss of hydraulic conductivity at -5.3 MPa. The artefactual reductions in k induced by centrifugation underestimate embolism resistance data of species with long vessels. A simple test is suggested to avoid this open vessel artefact and to ensure the reliability of this technique in future studies. © 2017 The Authors. New Phytologist © 2017 New Phytologist Trust.

  17. Stigma and Discrimination in HIV/AIDS; The greatest Challenge to ...

    African Journals Online (AJOL)

    The greatest challenge to the efforts of the various agencies and governments in the care, support and treatment of people living with HIV/AIDS, appears to be stigma and discrimination. Stigma and discrimination has to be addressed through public education, legislation to protect people living with HIV/AIDS and also by ...

  18. Pressure vessel for nuclear reactor plant consisting of several pre-stressed cast pressure vessels

    International Nuclear Information System (INIS)

    Bodmann, E.

    1984-01-01

    Several cylindrical pressure vessel components made of pressure castings are arranged on a sector of a circle around the cylindrical cast pressure vessel for accommodating the helium cooled HTR. Each component pressure vessel is connected to the reactor vessel by a horizontal gas duct. The contact surfaces between reactor and component pressure vessel are in one plane. In the spaces between the individual component pressure vessels, there are supporting blocks made of cast iron, which are hollow and also have flat surfaces. With the reactor vessel and the component pressure vessels they form a disc-shaped connecting part below and above the gas ducts. (orig./PW)

  19. Stress analysis in pressure vessels by mixed finite element methods taking into account shear deformation

    International Nuclear Information System (INIS)

    Franca, L.P.; Toledo, E.M.; Loula, A.F.D.; Garcia, E.L.M.

    1988-12-01

    A new finite element method is employed to approximate axisymmetric shell problems. This formulation enhances stability and accuracy, from thin to moderately thick shells, compared to the correspondent Galerkin finite element approximations. Numerical results illustrate the good performance of the present method on some typical pressure vessels aplications. (author) [pt

  20. Probabilistic retinal vessel segmentation

    Science.gov (United States)

    Wu, Chang-Hua; Agam, Gady

    2007-03-01

    Optic fundus assessment is widely used for diagnosing vascular and non-vascular pathology. Inspection of the retinal vasculature may reveal hypertension, diabetes, arteriosclerosis, cardiovascular disease and stroke. Due to various imaging conditions retinal images may be degraded. Consequently, the enhancement of such images and vessels in them is an important task with direct clinical applications. We propose a novel technique for vessel enhancement in retinal images that is capable of enhancing vessel junctions in addition to linear vessel segments. This is an extension of vessel filters we have previously developed for vessel enhancement in thoracic CT scans. The proposed approach is based on probabilistic models which can discern vessels and junctions. Evaluation shows the proposed filter is better than several known techniques and is comparable to the state of the art when evaluated on a standard dataset. A ridge-based vessel tracking process is applied on the enhanced image to demonstrate the effectiveness of the enhancement filter.

  1. ITER vacuum vessel design and electromagnetic analysis on in-vessel components

    International Nuclear Information System (INIS)

    Ioki, K.; Johnson, G.; Shimizu, K.; Williamson, D.; Iizuka, T.

    1995-01-01

    Major functional requirements for the vacuum vessel are to provide the first safety barrier and to support electromagnetic loads due to plasma disruptions and vertical displacement events, and to withstand plausible accidents without losing confinement. A double wall structure concept has been developed for the vacuum vessel due to its beneficial characteristics from the viewpoints of structural integrity and electrical continuity. An electromagnetic analysis of the blanket modules and the vacuum vessel has been performed to investigate force distributions on in-vessel components. According to the vertical displacement events (VDE) scenario, which assumes a critical q-value of 1.5, the total downward vertical force, induced by coupling between the eddy current and external fields, is about 110 MN. We have performed a stress analysis for the vacuum vessel using the VDE disruption forces acting on the blankets, and a maximum stress intensity of 112 MPa was obtained in the vicinity of the lower support of the vessel. (orig.)

  2. An automated vessel segmentation of retinal images using multiscale vesselness

    International Nuclear Information System (INIS)

    Ben Abdallah, M.; Malek, J.; Tourki, R.; Krissian, K.

    2011-01-01

    The ocular fundus image can provide information on pathological changes caused by local ocular diseases and early signs of certain systemic diseases, such as diabetes and hypertension. Automated analysis and interpretation of fundus images has become a necessary and important diagnostic procedure in ophthalmology. The extraction of blood vessels from retinal images is an important and challenging task in medical analysis and diagnosis. In this paper, we introduce an implementation of the anisotropic diffusion which allows reducing the noise and better preserving small structures like vessels in 2D images. A vessel detection filter, based on a multi-scale vesselness function, is then applied to enhance vascular structures.

  3. Development of PIE techniques for irradiated LWR pressure vessel steels

    International Nuclear Information System (INIS)

    Nishi, Masahiro; Kizaki, Minoru; Sukegawa, Tomohide

    1999-01-01

    For the evaluation of safety and integrity of light water reactors (LWRs), various post irradiation examinations (PIEs) of reactor pressure vessel (RPV) steels and fuel claddings have been carried out in the Research Hot Laboratory (RHL). In recent years, the instrumented Charpy impact testing machine was remodeled aiming at the improvement of accuracy and reliability. By this remodeling, absorbed energy and other useful information on impact properties can be delivered from the force-displacement curve for the evaluation of neutron irradiation embrittlement behavior of LWR-RPV steels at one-time striking. In addition, two advanced PIE technologies are now under development. One is the remote machining of mechanical test pieces from actual irradiated pressure vessel steels. The other is development of low-cycle and high-cycle fatigue test technology in order to clarify the post-irradiation fatigue characteristics of structural and fuel cladding materials. (author)

  4. Research vessels

    Digital Repository Service at National Institute of Oceanography (India)

    Rao, P.S.

    The role of the research vessels as a tool for marine research and exploration is very important. Technical requirements of a suitable vessel and the laboratories needed on board are discussed. The history and the research work carried out...

  5. An experimental investigation of the hemodynamic variations due to aplastic vessels within three-dimensional phantom models of the Circle of Willis.

    LENUS (Irish Health Repository)

    Fahy, Paul

    2013-09-10

    A complete circle of Willis (CoW) is found in approximately 30-50% of the population. Anatomical variations, such as absent or surgically clamped vessels, can result in undesirable flow patterns. These can affect the brain\\'s ability to maintain cerebral perfusion and the formation of cerebral aneurysms. An experimental test system was developed to simulate cerebral physiological conditions through three flexible 3D patient-specific models of complete and incomplete CoW geometries. Flow visualizations were performed with isobaric dyes and the mapped dye streamlines were tracked throughout the models. Three to seven flow impact locations were observed for all configurations, corresponding to known sites for aneurysmal formation. Uni and bi-directional cross-flows occurred along the communicating arteries. The greatest shunting of flow occurred for a missing pre-communicating anterior (A1) and posterior (P1) cerebral arteries. The anterior cerebral arteries had the greatest reduction (15-37%) in efferent flow rates for missing either a unilateral A1 or bilateral P1 segments. The bi-directional cross-flows, with multiple afferent flow mixing, observed along the communicating arteries may explain the propensity of aneurysm formation at these sites. Reductions in efferent flow rates due to aplastic vessel configurations may affect normal brain function.

  6. Application of large-eddy simulation to pressurized thermal shock: Assessment of the accuracy

    International Nuclear Information System (INIS)

    Loginov, M.S.; Komen, E.M.J.; Hoehne, T.

    2011-01-01

    Highlights: → We compare large-eddy simulation with experiment on the single-phase pressurized thermal shock problem. → Three test cases are considered, they cover entire range of mixing patterns. → The accuracy of the flow mixing in the reactor pressure vessel is assessed qualitatively and quantitatively. - Abstract: Pressurized Thermal Shock (PTS) is identified as one of the safety issues where Computational Fluid Dynamics (CFD) can bring real benefits. The turbulence modeling may impact overall accuracy of the calculated thermal loads on the vessel walls, therefore advanced methods for turbulent flows are required. The feasibility and mesh resolution of LES for single-phase PTS are assessed earlier in a companion paper. The current investigation deals with the accuracy of LES approach with respect to the experiment. Experimental data from the Rossendorf Coolant Mixing (ROCOM) facility is used as a basis for validation. Three test cases with different flow rates are considered. They correspond to a buoyancy-driven, a momentum-driven, and a transitional coolant mixing pattern in the downcomer. Time- and frequency-domain analysis are employed for comparison of the numerical and experimental data. The investigation shows a good qualitative prediction of the bulk flow patterns. The fluctuations are modeled correctly. A conservative estimate of the temperature drop near the wall can be obtained from the numerical results with safety factor of 1.1-1.3. In general, the current LES gives a realistic and reliable description of the considered coolant mixing experiments. The accuracy of the prediction is definitely improved with respect to earlier CFD simulations.

  7. MO-DE-210-05: Improved Accuracy of Liver Feature Motion Estimation in B-Mode Ultrasound for Image-Guided Radiation Therapy

    Energy Technology Data Exchange (ETDEWEB)

    O’Shea, T; Bamber, J; Harris, E [The Institute of Cancer Research & Royal Marsden, Sutton and London (United Kingdom)

    2015-06-15

    Purpose: In similarity-measure based motion estimation incremental tracking (or template update) is challenging due to quantization, bias and accumulation of tracking errors. A method is presented which aims to improve the accuracy of incrementally tracked liver feature motion in long ultrasound sequences. Methods: Liver ultrasound data from five healthy volunteers under free breathing were used (15 to 17 Hz imaging rate, 2.9 to 5.5 minutes in length). A normalised cross-correlation template matching algorithm was implemented to estimate tissue motion. Blood vessel motion was manually annotated for comparison with three tracking code implementations: (i) naive incremental tracking (IT), (ii) IT plus a similarity threshold (ST) template-update method and (iii) ST coupled with a prediction-based state observer, known as the alpha-beta filter (ABST). Results: The ABST method produced substantial improvements in vessel tracking accuracy for two-dimensional vessel motion ranging from 7.9 mm to 40.4 mm (with mean respiratory period: 4.0 ± 1.1 s). The mean and 95% tracking errors were 1.6 mm and 1.4 mm, respectively (compared to 6.2 mm and 9.1 mm, respectively for naive incremental tracking). Conclusions: High confidence in the output motion estimation data is required for ultrasound-based motion estimation for radiation therapy beam tracking and gating. The method presented has potential for monitoring liver vessel translational motion in high frame rate B-mode data with the required accuracy. This work is support by Cancer Research UK Programme Grant C33589/A19727.

  8. Integration of ITER in-vessel diagnostic components in the vacuum vessel

    International Nuclear Information System (INIS)

    Encheva, A.; Bertalot, L.; Macklin, B.; Vayakis, G.; Walker, C.

    2009-01-01

    The integration of ITER in-vessel diagnostic components is an important engineering activity. The positioning of the diagnostic components must correlate not only with their functional specifications but also with the design of the major parts of ITER torus, in particular the vacuum vessel, blanket modules, blanket manifolds, divertor, and port plugs, some of which are not yet finally designed. Moreover, the recently introduced Edge Localised Mode (ELM)/Vertical Stability (VS) coils mounted on the vacuum vessel inner wall call for not only more than a simple review of the engineering design settled down for several years now, but also for a change in the in-vessel distribution of the diagnostic components and their full impact has yet to be determined. Meanwhile, the procurement arrangement (a document defining roles and responsibilities of ITER Organization and Domestic Agency(s) (DAs) for each in-kind procurement including technical scope of work, quality assurance requirements, schedule, administrative matters) for the vacuum vessel must be finalized. These make the interface process even more challenging in terms of meeting the vacuum vessel (VV) procurement arrangement's deadline. The process of planning the installation of all the ITER diagnostics and integrating their installation into the ITER Integrated Project Schedule (IPS) is now underway. This paper covers the progress made recently on updating and issuing the interfaces of the in-vessel diagnostic components with the vacuum vessel, outlines the requirements for their attachment and summarises the installation sequence.

  9. FFTF and CRBRP reactor vessels

    International Nuclear Information System (INIS)

    Morgan, R.E.

    1977-01-01

    The Fast Flux Test Facility (FFTF) reactor vessel and the Clinch River Breeder Reactor Plant (CRBRP) reactor vessel each serve to enclose a fast spectrum reactor core, contain the sodium coolant, and provide support and positioning for the closure head and internal structure. Each vessel is located in its reactor cavity and is protected by a guard vessel which would ensure continued decay heat removal capability should a major system leak develop. Although the two plants have significantly different thermal power ratings, 400 megawatts for FFTF and 975 megawatts for CRBRP, the two reactor vessels are comparable in size, the CRBRP vessel being approximately 28% longer than the FFTF vessel. The FFTF vessel diameter was controlled by the space required for the three individual In-Vessel Handling Machines and Instrument Trees. Utilization of the triple rotating plug scheme for CRBRP refueling enables packaging of the larger CRBRP core in a vessel the same diameter as the FFTF vessel

  10. Tumor Blood Vessel Dynamics

    Science.gov (United States)

    Munn, Lance

    2009-11-01

    ``Normalization'' of tumor blood vessels has shown promise to improve the efficacy of chemotherapeutics. In theory, anti-angiogenic drugs targeting endothelial VEGF signaling can improve vessel network structure and function, enhancing the transport of subsequent cytotoxic drugs to cancer cells. In practice, the effects are unpredictable, with varying levels of success. The predominant effects of anti-VEGF therapies are decreased vessel leakiness (hydraulic conductivity), decreased vessel diameters and pruning of the immature vessel network. It is thought that each of these can influence perfusion of the vessel network, inducing flow in regions that were previously sluggish or stagnant. Unfortunately, when anti-VEGF therapies affect vessel structure and function, the changes are dynamic and overlapping in time, and it has been difficult to identify a consistent and predictable normalization ``window'' during which perfusion and subsequent drug delivery is optimal. This is largely due to the non-linearity in the system, and the inability to distinguish the effects of decreased vessel leakiness from those due to network structural changes in clinical trials or animal studies. We have developed a mathematical model to calculate blood flow in complex tumor networks imaged by two-photon microscopy. The model incorporates the necessary and sufficient components for addressing the problem of normalization of tumor vasculature: i) lattice-Boltzmann calculations of the full flow field within the vasculature and within the tissue, ii) diffusion and convection of soluble species such as oxygen or drugs within vessels and the tissue domain, iii) distinct and spatially-resolved vessel hydraulic conductivities and permeabilities for each species, iv) erythrocyte particles advecting in the flow and delivering oxygen with real oxygen release kinetics, v) shear stress-mediated vascular remodeling. This model, guided by multi-parameter intravital imaging of tumor vessel structure

  11. The TPX vacuum vessel and in-vessel components

    International Nuclear Information System (INIS)

    Heitzenroeder, P.; Bialek, J.; Ellis, R.; Kessel, C.; Liew, S.

    1994-01-01

    The Tokamak Physics Experiment (TPX) is a superconducting tokamak with double-null diverters. TPX is designed for 1,000-second discharges with the capability of being upgraded to steady state operation. High neutron yields resulting from the long duration discharges require that special consideration be given to materials and maintainability. A unique feature of the TPX is the use of a low activation, titanium alloy vacuum vessel. Double-wall vessel construction is used since it offers an efficient solution for shielding, bakeout and cooling. Contained within the vacuum vessel are the passive coil system, Plasma Facing Components (PFCs), magnetic diagnostics, and the internal control coils. All PFCs utilize carbon-carbon composites for exposed surfaces

  12. Accuracy of automated software-guided detection of significant coronary artery stenosis by CT angiography: comparison with invasive catheterisation

    International Nuclear Information System (INIS)

    Anders, Katharina; Uder, Michael; Achenbach, Stephan; Petit, Isabel; Daniel, Werner G.; Pflederer, Tobias

    2013-01-01

    True automated detection of coronary artery stenoses might be useful whenever expert evaluation is not available, or as a ''second reader'' to enhance diagnostic confidence. We evaluated the accuracy of a PC-based stenosis detection tool alone and combined with expert interpretation. One hundred coronary CT angiography datasets were evaluated with the automated software alone, by manual interpretation (axial images, multiplanar reformations and maximum intensity projections in free double-oblique planes), and by expert interpretation aware of the automated findings. Stenoses ≥ 50 % were noted per-vessel and per-patient, and compared with invasive angiography. Automated post-processing was successful in 90 % of patients (88 % of vessels). When excluding uninterpretable datasets, per-patient sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV) were 89 %, 79 %, 74 % and 92 % (per-vessel: 82 %, 85 %, 48 % and 96 %). All 100 datasets were evaluable by expert interpretation. Per-patient sensitivity, specificity, PPV and NPV were 95 %, 95 %, 93 % and 97 % (per-vessel: 89 %,98 %, 88 % and 98 %). Knowing the results of automated interpretation did not improve the performance of expert readers. Automated off-line post-processing of coronary CT angiography shows adequate sensitivity, but relatively low specificity in coronary stenosis detection. It does not increase accuracy of expert interpretation. Failure of post-processing in 10 % of all patients necessitates additional manual image work-up. (orig.)

  13. Fracture probability evaluation of a LWR pressure vessel

    International Nuclear Information System (INIS)

    Grandemange, J.; Pellissier-Tanon, A.; Quero, J.; Carnino, A.; Dufresne, J.

    1978-01-01

    Fracture probability evaluation, of a LWR pressure vessel have been performed in the past, using statistical data from conventional plant. A more accurate evaluation has been requested in 1976 from the SCSIN to the CEA. With this object, a joint collaboration agreement has been signed between CEA, EURATOM/ISPRA and FRAMATOME. The whole program proceeding from this agreement is managed by a joint board including the three partners. The basic objective of this program is to develop a method which integrates, or makes it possible to integrate at a later stage, the greatest number of significant parameters. Also, in order to prepare the practical applications, a special effort is being made to collect the data corresponding to these parameters. Parallel basic research program have been launched in order to clarify our knowledge on some important parts of the main factors contributing to the evaluation. The results of this research will be progressively introduced into the method or will help checking its validity

  14. An assessment of acoustic emission for nuclear pressure vessel monitoring

    International Nuclear Information System (INIS)

    Scruby, C.B.

    1983-01-01

    Recent research has greatly improved our understanding of the basic mechanisms of deformation and fracture that generate detectable acoustic emission signals in structural steels. A critical review of the application of acoustic emission (AE) to the fabrication, proof testing and in-service monitoring of nuclear pressure vessels is presented in the light of this improved understanding. The detectability of deformation and fracture processes in pressure vessel steels is discussed, and recommendations made for improving source location accuracy and the development of quantitative source assessment techniques. Published data suggest that AE can make an important contribution to fabrication monitoring, and to the detection of defects in lower toughness materials during vessel proof testing. In high toughness materials, however, the signals generated during ductile crack growth may frequently be too weak for reliable detection. The feasibility of AE for continuous monitoring has not yet been adequately demonstrated because of high background noise levels and uncertainty about AE signal strengths from the defect growth processes that occur in service. In-service leak detection by AE shows considerable promise. It is recommended that further tests are carried out with realistic defects, and under realistic conditions of loading (including thermal shock and fatigue) and of environment. (author)

  15. Deuterium in-vessel retention characterisation through the use of particle balance on Tore Supra

    International Nuclear Information System (INIS)

    Bucalossi, J.; Brosset, C.; Pegourie, B.; Tsitrone, E.; Dufour, E.; Eckedahl, A.; Geraud, A.; Goniche, M.; Gunn, J.; Loarer, T.; Monier-Garbet, P.; Vallet, J.C.; Vartanian, S.

    2007-01-01

    Fuel retention inside plasma facing components will be a crucial issue not only in fusion reactors of the future, but also in ITER. The estimation of the fraction of the fuel which remains trapped inside the vessel is quite a difficult task. Particle balance analysis provides information for the whole vacuum chamber as a function of time and can be use to monitor the tritium in-vessel retention in real-time. On Tore Supra with a careful choice and position of pressure sensors, proper calibration procedures, the accuracy of the balance is around 10%. Particle balance analysis have been performed on many long pulse discharges and deuterium in-vessel retention has been found to be a constant around 5 x 10 20 D/s after several minutes of plasma. The evolution of the retention rate with plasma parameters indicates that deuterium bulk implantation and diffusion could dominate codeposition with carbon atoms. Particle balance is a powerful tool that should be implemented in ITER

  16. An experimental study on feasibility of ex-vessel cooling through the external guide vessel

    International Nuclear Information System (INIS)

    Kang, Kyoung-Ho; Kim, Jong-Hwan; Park, Rae-Jun; Kim, Sang-Baik

    2000-01-01

    This paper presents the results of a series of experiments for assessing the efficacy of ex-vessel cooling through the external guide vessel during a severe accident. Four tests were performed in the LAVA test facility at KAERI, varying the boundary conditions at the outer surface of the vessel. The first test was a dry condition test conducted without cooling the outside of the vessel. On the other hand, in the second test, the cooling of the vessel surface was produced by gravity-driven forced injection of water along the annular gap of 25 mm between the vessel and the external guide vessel. Water flow rate was about 0.85 kg/s and total mass of available water was 300 kg. For the evaluation of the water flow rate effect, the third test was performed with a pool type cooling in the annulus without any circulation of water. These two external cooling tests were performed under elevated pressure of about 1.6 MPa. Finally, the fourth test was conducted under atmospheric pressure to evaluate the effect of system pressure on boiling heat transfer characteristics. In the dry test and the pool type ex-vessel cooling test performed under atmospheric pressure, the vessel was failed by a melt penetration at about 40 degree upper position from the vessel bottom, which is coincident with the boundary of the Al 2 O 3 /Fe melt separated layers. On the other hand, in both of the ex-vessel cooling tests conducted under elevated pressure of about 1.6 MPa, the vessel didn't fail. Compared with the pool boiling test, the vessel experienced effective cooling due to the inlet flow in the forced flow test. Synthesized the results of the tests, it was shown that the heat removal with ex-vessel cooling through the guide vessel is feasible, but the additional evaluations should be performed to guarantee enough thermal margin. (author)

  17. Special enclosure for a pressure vessel

    International Nuclear Information System (INIS)

    Wedellsborg, B.W.; Wedellsborg, U.W.

    1993-01-01

    A pressure vessel enclosure is described comprising a primary pressure vessel, a first pressure vessel containment assembly adapted to enclose said primary pressure vessel and be spaced apart therefrom, a first upper pressure vessel jacket adapted to enclose the upper half of said first pressure vessel containment assembly and be spaced apart therefrom, said upper pressure vessel jacket having an upper rim and a lower rim, each of said rims connected in a slidable relationship to the outer surface of said first pressure vessel containment assembly, mean for connecting in a sealable relationship said upper rim of said first upper pressure vessel jacket to the outer surface of said first pressure vessel containment assembly, means for connecting in a sealable relationship said lower rim of said first upper pressure vessel jacket to the outer surface of said first pressure vessel containment assembly, a first lower pressure vessel jacket adapted to enclose the lower half of said first pressure vessel containment assembly and be spaced apart therefrom, said lower pressure vessel jacket having an upper rim connected in a slidable relationship to the outer surface of said first pressure vessel containment assembly, and means for connecting in a sealable relationship said upper rim of said first lower pressure vessel jacket to the outer surface of said first pressure vessel containment assembly, a second upper pressure vessel jacket adapted to enclose said first upper pressure vessel jacket and be spaced apart therefrom, said second upper pressure vessel jacket having an upper rim and a lower rim, each of said rims adapted to slidably engage the outer surface of said first upper pressure vessel jacket, means for sealing said rims, a second lower pressure vessel jacket adapted to enclose said first lower pressure vessel jacket and be spaced apart therefrom

  18. Vessel classification method based on vessel behavior in the port of Rotterdam

    NARCIS (Netherlands)

    Zhou, Y.; Daamen, W.; Vellinga, T.; Hoogendoorn, S.P.

    2015-01-01

    AIS (Automatic Identification System) data have proven to be a valuable source to investigate vessel behavior. The analysis of AIS data provides a possibility to recognize vessel behavior patterns in a waterway area. Furthermore, AIS data can be used to classify vessel behavior into several

  19. Was ocean acidification responsible for history's greatest extinction?

    Science.gov (United States)

    Schultz, Colin

    2011-11-01

    Two hundred fifty million years ago, the world suffered the greatest recorded extinction of all time. More than 90% of marine animals and a majority of terrestrial species disappeared, yet the cause of the Permian-Triassic boundary (PTB) dieoff remains unknown. Various theories abound, with most focusing on rampant Siberian volcanism and its potential consequences: global warming, carbon dioxide poisoning, ocean acidification, or the severe drawdown of oceanic dissolved oxygen levels, also known as anoxia. To narrow the range of possible causes, Montenegro et al. ran climate simulations for PTB using the University of Victoria Earth System Climate Model, a carbon cycle-climate coupled general circulation model.

  20. Vessel Operating Units (Vessels)

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — This data set contains data for vessels that are greater than five net tons and have a current US Coast Guard documentation number. Beginning in1979, the NMFS...

  1. Detection and sizing of inside-surface cracks in reactor pressure vessels

    International Nuclear Information System (INIS)

    Kamata, Hiroshi; Kanazawa, Katsuo; Satoh, Kunio; Honma, Takashi

    1984-01-01

    According to the past operational experience of LWRs, most of the defects arising in reactor pressure vessels accompanying operation are cracks occurring in the build up welding of austenitic stainless steel on the internal surfaces. The detection of these cracks has been carried out by ultrasonic flaw detection from outside in BWRs and from inside in PWRs as in-service inspection. However, there are difficulties such as ultrasonic echoes often occur though defects do not exist, and the quantitative evaluation of detected cracks is difficult by this method because of its accuracy. One of the means to reduce the first difficulty is to use eddy current method together to help the judgement, and for overcoming the second, the ultrasonic method catching end peak echo, that catching diffracted waves, eddy current method and electric resistance method were tried and compared. It is desirable to detect cracks in early stage before they reach parent material. The techniques to detect cracks on the internal surfaces of pressure vessels from the inside and to measure the depth are reported in this paper. The methods of flaw detection examined and the instruments used, the experimental method and the results are reported. It was concluded that eddy current method can be used as the backup for ultrasonic remote flaw detection, and the accuracy of depth measurement was the highest in ultrasonic diffraction wave method. (Kako, I.)

  2. Coping and acceptance: the greatest challenge for veterans with intestinal stomas.

    Science.gov (United States)

    Krouse, Robert S; Grant, Marcia; Rawl, Susan M; Mohler, M Jane; Baldwin, Carol M; Coons, Stephen Joel; McCorkle, Ruth; Schmidt, C Max; Ko, Clifford Y

    2009-03-01

    Intestinal stomas (ostomies) create challenges for veterans. The goal of this qualitative analysis was to understand better patients' perspectives regarding their greatest challenge. Ostomates at three Veterans Affairs locations were surveyed using the modified City of Hope Quality of Life-Ostomy questionnaire that contained an open-ended request for respondents to describe their greatest challenge. The response rate was 51% (239 of 467); 68% (163 of 239) completed the open-ended item. Content analysis was performed by an experienced qualitative research team. Coping and acceptance were the most commonly addressed themes. The most frequently expressed issues and advice were related to a need for positive thinking and insight regarding adjustment over time. Coping strategies included the use of humor, recognition of positive changes resulting from the stoma, and normalization of life with an ostomy. Coping and acceptance are common themes described by veterans with an intestinal stoma. Health-care providers can assist veterans by utilizing ostomate self-management strategies, experience, and advice.

  3. A fracture mechanics and reliability based method to assess non-destructive testings for pressure vessels

    International Nuclear Information System (INIS)

    Kitagawa, Hideo; Hisada, Toshiaki

    1979-01-01

    Quantitative evaluation has not been made on the effects of carrying out preservice and in-service nondestructive tests for securing the soundness, safety and maintainability of pressure vessels, spending large expenses and labor. Especially the problems concerning the time and interval of in-service inspections lack the reasonable, quantitative evaluation method. In this paper, the problems of pressure vessels are treated by having developed the analysis method based on reliability technology and probability theory. The growth of surface cracks in pressure vessels was estimated, using the results of previous studies. The effects of nondestructive inspection on the defects in pressure vessels were evaluated, and the influences of many factors, such as plate thickness, stress, the accuracy of inspection and so on, on the effects of inspection, and the method of evaluating the inspections at unequal intervals were investigated. The analysis of reliability taking in-service inspection into consideration, the evaluation of in-service inspection and other affecting factors through the typical examples of analysis, and the review concerning the time of inspection are described. The method of analyzing the reliability of pressure vessels, considering the growth of defects and preservice and in-service nondestructive tests, was able to be systematized so as to be practically usable. (Kako, I.)

  4. Improvement to reactor vessel

    International Nuclear Information System (INIS)

    1974-01-01

    The vessel described includes a prestressed concrete vessel containing a chamber and a removable cover closing this chamber. The cover is in concrete and is kept in its closed position by main and auxiliary retainers, comprising fittings integral with the concrete of the vessel. The auxiliary retainers pass through the concrete of the cover. This improvement may be applied to BWR, PWR and LMFBR type reactor vessel [fr

  5. Integrating Multiple Autonomous Underwater Vessels, Surface Vessels and Aircraft into Oceanographic Research Vessel Operations

    Science.gov (United States)

    McGillivary, P. A.; Borges de Sousa, J.; Martins, R.; Rajan, K.

    2012-12-01

    Autonomous platforms are increasingly used as components of Integrated Ocean Observing Systems and oceanographic research cruises. Systems deployed can include gliders or propeller-driven autonomous underwater vessels (AUVs), autonomous surface vessels (ASVs), and unmanned aircraft systems (UAS). Prior field campaigns have demonstrated successful communication, sensor data fusion and visualization for studies using gliders and AUVs. However, additional requirements exist for incorporating ASVs and UASs into ship operations. For these systems to be optimally integrated into research vessel data management and operational planning systems involves addressing three key issues: real-time field data availability, platform coordination, and data archiving for later analysis. A fleet of AUVs, ASVs and UAS deployed from a research vessel is best operated as a system integrated with the ship, provided communications among them can be sustained. For this purpose, Disruptive Tolerant Networking (DTN) software protocols for operation in communication-challenged environments help ensure reliable high-bandwidth communications. Additionally, system components need to have considerable onboard autonomy, namely adaptive sampling capabilities using their own onboard sensor data stream analysis. We discuss Oceanographic Decision Support System (ODSS) software currently used for situational awareness and planning onshore, and in the near future event detection and response will be coordinated among multiple vehicles. Results from recent field studies from oceanographic research vessels using AUVs, ASVs and UAS, including the Rapid Environmental Picture (REP-12) cruise, are presented describing methods and results for use of multi-vehicle communication and deliberative control networks, adaptive sampling with single and multiple platforms, issues relating to data management and archiving, and finally challenges that remain in addressing these technological issues. Significantly, the

  6. The greatest hydroelectric power plant in the world. Itaipu Hydroelectric Power Plant

    International Nuclear Information System (INIS)

    Andonov - Chento, Ilija

    2004-01-01

    Details to demonstrate the size and engineering achievements of one of the world's greatest hydroelectric power plant are given. Principal technical features of construction and operation of the Itaipu Dam are tabulated and discussed

  7. In-vessel tritium

    International Nuclear Information System (INIS)

    Ueda, Yoshio; Ohya, Kaoru; Ashikawa, Naoko; Ito, Atsushi M.; Kato, Daiji; Kawamura, Gakushi; Takayama, Arimichi; Tomita, Yukihiro; Nakamura, Hiroaki; Ono, Tadayoshi; Kawashima, Hisato; Shimizu, Katsuhiro; Takizuka, Tomonori; Nakano, Tomohide; Nakamura, Makoto; Hoshino, Kazuo; Kenmotsu, Takahiro; Wada, Motoi; Saito, Seiki; Takagi, Ikuji; Tanaka, Yasunori; Tanabe, Tetsuo; Yoshida, Masafumi; Toma, Mitsunori; Hatayama, Akiyoshi; Homma, Yuki; Tolstikhina, Inga Yu.

    2012-01-01

    The in-vessel tritium research is closely related to the plasma-materials interaction. It deals with the edge-plasma-wall interaction, the wall erosion, transport and re-deposition of neutral particles and the effect of neutral particles on the fuel recycling. Since the in-vessel tritium shows a complex nonlinear behavior, there remain many unsolved problems. So far, behaviors of in-vessel tritium have been investigated by two groups A01 and A02. The A01 group performed experiments on accumulation and recovery of tritium in thermonuclear fusion reactors and the A02 group studied theory and simulation on the in-vessel tritium behavior. In the present article, outcomes of the research are reviewed. (author)

  8. Retinal Vessel Segmentation via Structure Tensor Coloring and Anisotropy Enhancement

    Directory of Open Access Journals (Sweden)

    Mehmet Nergiz

    2017-11-01

    Full Text Available Retinal vessel segmentation is one of the preliminary tasks for developing diagnosis software systems related to various retinal diseases. In this study, a fully automated vessel segmentation system is proposed. Firstly, the vessels are enhanced using a Frangi Filter. Afterwards, Structure Tensor is applied to the response of the Frangi Filter and a 4-D tensor field is obtained. After decomposing the Eigenvalues of the tensor field, the anisotropy between the principal Eigenvalues are enhanced exponentially. Furthermore, this 4-D tensor field is converted to the 3-D space which is composed of energy, anisotropy and orientation and then a Contrast Limited Adaptive Histogram Equalization algorithm is applied to the energy space. Later, the obtained energy space is multiplied by the enhanced mean surface curvature of itself and the modified 3-D space is converted back to the 4-D tensor field. Lastly, the vessel segmentation is performed by using Otsu algorithm and tensor coloring method which is inspired by the ellipsoid tensor visualization technique. Finally, some post-processing techniques are applied to the segmentation result. In this study, the proposed method achieved mean sensitivity of 0.8123, 0.8126, 0.7246 and mean specificity of 0.9342, 0.9442, 0.9453 as well as mean accuracy of 0.9183, 0.9442, 0.9236 for DRIVE, STARE and CHASE_DB1 datasets, respectively. The mean execution time of this study is 6.104, 6.4525 and 18.8370 s for the aforementioned three datasets respectively.

  9. Changes in peripapillary blood vessel density in Graves' orbitopathy after orbital decompression surgery as measured by optical coherence tomography angiography.

    Science.gov (United States)

    Lewis, Kyle T; Bullock, John R; Drumright, Ryan T; Olsen, Matthew J; Penman, Alan D

    2018-03-08

    The purpose is to evaluate the utility of optical coherence tomography (OCT) angiography in the evaluation of Graves' orbitopathy (GO) and response to orbital decompression in patients with and without dysthyroid optic neuropathy (DON). This was a single-center, prospective case series in a cohort of 12 patients (24 orbits) with GO and ±DON, (6 orbits) who underwent bilateral orbital decompression. All patients underwent pre- and postoperative OCT angiography of the peripapillary area. Vessel density indices were calculated in a 4.5 mm × 4.5 mm ellipsoid centered on the optic disk using split-spectrum amplitude decorrelation angiography algorithm, producing the vessel density measurements. Mean change in vessel density indices was compared between pre- and postoperative sessions and between patients with and without DON. Patient 1, a 34-year-old male with GO and unilateral DON OD, showed a significant reduction in blood vessel density indices oculus dexter (OD) (DON eye) after decompression while a more modest reduction was found oculus sinister (OS) with the greatest change noted intrapapillary. Patient 2, a 50-year-old male with DON OU, showed worsening neuropathy following decompression OD that was confirmed by angiographic density indices. Patient 3, a 55-year-female with DON, showed a reduction in blood vessel density OD and increased density OS. Patients without DON showed overall less impressive changes in indices as compared to those with DON. Using OCT angiography, response to surgical treatment in GO orbits, more so in orbits with DON, can be demonstrated and quantified using vessel density indices with reproducibility.

  10. Simulation of time of flight defraction signals for reactor vessel head penetrations

    Energy Technology Data Exchange (ETDEWEB)

    Lim, Tae Hun; Kim, Young Sik; Lee, Jeong Seok [KHNP Central Research Institute, Daejeon (Korea, Republic of)

    2016-08-15

    The simulation of nondestructive testing has been used in the prediction of the signal characteristics of various defects and in the development of the procedures. CIVA, a simulation tool dedicated to nondestructive testing, has good accuracy and speed, and provides a three-dimensional graphical user interface for improved visualization and familiar data displays consistent with an NDE technique. Even though internal validations have been performed by the CIVA software development specialists, an independent validation study is necessary for the assessment of the accuracy of the software prior to practical use. In this study, time of flight diffraction signals of ultrasonic inspection of a calibration block for reactor vessel head penetrations were simulated using CIVA. The results were compared to the experimentally inspected signals. The accuracy of the simulated signals and the possible range for simulation were verified. It was found that, there is a good agreement between the CIVA simulated and experimental results in the A-scan signal, B-scan image, and measurement of depth.

  11. Simulation of time of flight defraction signals for reactor vessel head penetrations

    International Nuclear Information System (INIS)

    Lim, Tae Hun; Kim, Young Sik; Lee, Jeong Seok

    2016-01-01

    The simulation of nondestructive testing has been used in the prediction of the signal characteristics of various defects and in the development of the procedures. CIVA, a simulation tool dedicated to nondestructive testing, has good accuracy and speed, and provides a three-dimensional graphical user interface for improved visualization and familiar data displays consistent with an NDE technique. Even though internal validations have been performed by the CIVA software development specialists, an independent validation study is necessary for the assessment of the accuracy of the software prior to practical use. In this study, time of flight diffraction signals of ultrasonic inspection of a calibration block for reactor vessel head penetrations were simulated using CIVA. The results were compared to the experimentally inspected signals. The accuracy of the simulated signals and the possible range for simulation were verified. It was found that, there is a good agreement between the CIVA simulated and experimental results in the A-scan signal, B-scan image, and measurement of depth

  12. Automation of calculation of fastening of non-standard freights on sea vessels

    Directory of Open Access Journals (Sweden)

    Андрій Валерійович Пархотько

    2015-11-01

    Full Text Available Correct positioning and fastening of freights are important safety conditions of navigation. Unreliable positioning and fastening of freights results in shipwreck and is the reason for injuries and losses of human lives both in the sea and during loading and unloading. To solve the above-mentioned problems, the International Maritime Organization publishes manuals in the form of either the Assembly resolutions, or the circulars approved by Maritime Safety Committee. The correct definition of necessary quantity of lashings and their positioning has the greatest impact on safe fastening of freights. The sea being rough, the vessel is accelerated both in longitudinal, and vertical and prevailing cross directions. The forces created by these accelerations generate the majority of the problems in fastening. The order of calculations of the force moments and forces acting upon the freights being shipped by sea vessels has been shown in the article. To know the proper number of lashings the calculations of the forces acting upon the freights being shipped as compared with the forces holding the freights and taking into account the strength, the number and the fastening angle of the lashings must be made. Оption of realization of algorithm of calculation with use of the а computer program to make these calculations has been offered. Some recommendations so that the program could be used by the management of the vessel, the surveyor companies and technologists of the port have been given as well as an example of such a calculation

  13. Radiation field analyses in reactor vessels of PWRs

    Energy Technology Data Exchange (ETDEWEB)

    Fukuya, Koji; Nakata, Hayato; Fujii, Katsuhiko; Kimura, Itsuro [Institute of Nuclear Safety System, Inc., Mihama, Fukui (Japan); Ohmura, Masaki; Kitagawa, Hideo [Mitsubishi Heavy Industries, Ltd., Nuclear Energy Systems Engineering Center, Yokohama, Kanagawa (Japan); Itoh, Taku; Shin, Kazuo [Kyoto Univ. (Japan). Faculty of Engineering

    2002-09-01

    Radiation analysis in reactor vessels of PWRs were performed using three calculation codes (two dimensional transport code DORT, three dimensional transport code TORT and three dimensional Monte Carlo code MCNP) and three cross section data (ENDF/B-IV, ENDF/B-VI and JENDL3.2) to improve accuracy of estimation for neutron flux, gamma-ray flux and displacement per atom (dpa). The calculations using DORT at a surveillance position agreed with the dosimetry measurements for the three cross sections. The calculated neutron spectra using the three cross sections at the reactor vessels and the surveillance position were quite similar to each other. The difference in the cross sections gave small impacts on the fluence estimation. The ratio of the calculations to the measurements using TORT was similar to those using DORT, indicating that TORT is applicable to the radiation analysis in PWRs. The MCNP calculations resulted in a similar agreement with the dosimeter measurement to the DORT calculation while they needed a long computing time. Improvement of calculation techniques is needed for application of MCNP. The calculated dpa agreed within 10% for the three cross sections. (author)

  14. NCSX Vacuum Vessel Fabrication

    International Nuclear Information System (INIS)

    Viola ME; Brown T; Heitzenroeder P; Malinowski F; Reiersen W; Sutton L; Goranson P; Nelson B; Cole M; Manuel M; McCorkle D.

    2005-01-01

    The National Compact Stellarator Experiment (NCSX) is being constructed at the Princeton Plasma Physics Laboratory (PPPL) in conjunction with the Oak Ridge National Laboratory (ORNL). The goal of this experiment is to develop a device which has the steady state properties of a traditional stellarator along with the high performance characteristics of a tokamak. A key element of this device is its highly shaped Inconel 625 vacuum vessel. This paper describes the manufacturing of the vessel. The vessel is being fabricated by Major Tool and Machine, Inc. (MTM) in three identical 120 o vessel segments, corresponding to the three NCSX field periods, in order to accommodate assembly of the device. The port extensions are welded on, leak checked, cut off within 1-inch of the vessel surface at MTM and then reattached at PPPL, to accommodate assembly of the close-fitting modular coils that surround the vessel. The 120 o vessel segments are formed by welding two 60 o segments together. Each 60 o segment is fabricated by welding ten press-formed panels together over a collapsible welding fixture which is needed to precisely position the panels. The vessel is joined at assembly by welding via custom machined 8-inch (20.3 cm) wide spacer ''spool pieces''. The vessel must have a total leak rate less than 5 X 10 -6 t-l/s, magnetic permeability less than 1.02(micro), and its contours must be within 0.188-inch (4.76 mm). It is scheduled for completion in January 2006

  15. Simulation of In-Vessel Corium Retention through External Reactor Vessel Cooling for SMART using SIMPLE

    Energy Technology Data Exchange (ETDEWEB)

    Jang, Jin-Sung; Son, Donggun; Park, Rae-Joon [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2016-10-15

    Thermal load analysis from the corium pool to the outer reactor vessel in the lower plenum of the reactor vessel is necessary to evaluate the effect of the IVR-ERVC during a severe accident for SMART. A computational code called SIMPLE (Sever Invessel Melt Progression in Lower plenum Environment) has been developed for analyze transient behavior of molten corium in the lower plenum, interaction between corium and coolant, and heat-up and ablation of reactor vessel wall. In this study, heat load analysis of the reactor vessel for SMART has been conducted using the SIMPLE. Transient behavior of the molten corium in the lower plenum and IVR-ERVC for SMART has been simulated using SIMPLE. Heat flux from the corium pool to the outer reactor vessel is concentrated in metallic layer by the focusing effect. As a result, metallic layer shows higher temperature than the oxidic layer. Also, vessel wall of metallic layer has been ablated by the high in-vessel temperature. Ex-vessel temperature of the metallic layer was maintained 390 K and vessel thickness was maintained 14 cm. It means that the reactor vessel integrity is maintained by the IVR-ERVC.

  16. A computational algorithm addressing how vessel length might depend on vessel diameter

    Science.gov (United States)

    Jing Cai; Shuoxin Zhang; Melvin T. Tyree

    2010-01-01

    The objective of this method paper was to examine a computational algorithm that may reveal how vessel length might depend on vessel diameter within any given stem or species. The computational method requires the assumption that vessels remain approximately constant in diameter over their entire length. When this method is applied to three species or hybrids in the...

  17. Adaptable three-dimensional Monte Carlo modeling of imaged blood vessels in skin

    Science.gov (United States)

    Pfefer, T. Joshua; Barton, Jennifer K.; Chan, Eric K.; Ducros, Mathieu G.; Sorg, Brian S.; Milner, Thomas E.; Nelson, J. Stuart; Welch, Ashley J.

    1997-06-01

    In order to reach a higher level of accuracy in simulation of port wine stain treatment, we propose to discard the typical layered geometry and cylindrical blood vessel assumptions made in optical models and use imaging techniques to define actual tissue geometry. Two main additions to the typical 3D, weighted photon, variable step size Monte Carlo routine were necessary to achieve this goal. First, optical low coherence reflectometry (OLCR) images of rat skin were used to specify a 3D material array, with each entry assigned a label to represent the type of tissue in that particular voxel. Second, the Monte Carlo algorithm was altered so that when a photon crosses into a new voxel, the remaining path length is recalculated using the new optical properties, as specified by the material array. The model has shown good agreement with data from the literature. Monte Carlo simulations using OLCR images of asymmetrically curved blood vessels show various effects such as shading, scattering-induced peaks at vessel surfaces, and directionality-induced gradients in energy deposition. In conclusion, this augmentation of the Monte Carlo method can accurately simulate light transport for a wide variety of nonhomogeneous tissue geometries.

  18. Pressure vessel design manual

    CERN Document Server

    Moss, Dennis R

    2013-01-01

    Pressure vessels are closed containers designed to hold gases or liquids at a pressure substantially different from the ambient pressure. They have a variety of applications in industry, including in oil refineries, nuclear reactors, vehicle airbrake reservoirs, and more. The pressure differential with such vessels is dangerous, and due to the risk of accident and fatality around their use, the design, manufacture, operation and inspection of pressure vessels is regulated by engineering authorities and guided by legal codes and standards. Pressure Vessel Design Manual is a solutions-focused guide to the many problems and technical challenges involved in the design of pressure vessels to match stringent standards and codes. It brings together otherwise scattered information and explanations into one easy-to-use resource to minimize research and take readers from problem to solution in the most direct manner possible. * Covers almost all problems that a working pressure vessel designer can expect to face, with ...

  19. LANL Robotic Vessel Scanning

    Energy Technology Data Exchange (ETDEWEB)

    Webber, Nels W. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2015-11-25

    Los Alamos National Laboratory in J-1 DARHT Operations Group uses 6ft spherical vessels to contain hazardous materials produced in a hydrodynamic experiment. These contaminated vessels must be analyzed by means of a worker entering the vessel to locate, measure, and document every penetration mark on the vessel. If the worker can be replaced by a highly automated robotic system with a high precision scanner, it will eliminate the risks to the worker and provide management with an accurate 3D model of the vessel presenting the existing damage with the flexibility to manipulate the model for better and more in-depth assessment.The project was successful in meeting the primary goal of installing an automated system which scanned a 6ft vessel with an elapsed time of 45 minutes. This robotic system reduces the total time for the original scope of work by 75 minutes and results in excellent data accumulation and transmission to the 3D model imaging program.

  20. Vessel Eddy Current Measurement for the National Spherical Torus Experiment (NSTX)

    International Nuclear Information System (INIS)

    Gates, D.A.; Menard, J.; Marsala, R.

    2004-01-01

    A simple analog circuit that measures the NSTX axisymmetric eddy current distribution has been designed and constructed. It is based on simple circuit model of the NSTX vacuum vessel that was calibrated using a special axisymmetric eddy current code which was written so that accuracy was maintained in the vicinity of the current filaments. The measurement and the model have been benchmarked against data from numerous vacuum shots and they are in excellent agreement. This is an important measurement that helps give more accurate equilibrium reconstructions

  1. PDX vacuum vessel stress analysis

    International Nuclear Information System (INIS)

    Nikodem, Z.D.

    1975-01-01

    A stress analysis of PDX vacuum vessel is described and the summary of results is presented. The vacuum vessel is treated as a toroidal shell of revolution subjected to an internal vacuum. The critical buckling pressure is calculated. The effects of the geometrical discontinuity at the juncture of toroidal shell head and cylindrical outside wall, and the concavity of the cylindrical wall are examined. An effect of the poloidal field coil supports and the vessel outside supports on the stress distribution in the vacuum vessel is determined. A method evaluating the influence of circular ports in the vessel wall on the stress level in the vessel is outlined

  2. Ex-vessel corium coolability sensitivity study with the CORQUENCH code

    International Nuclear Information System (INIS)

    Robb, Kevin; Corradini, Michael

    2009-01-01

    An unresolved safety issue for light water reactor beyond design basis accidents is the coolability and stabilization of ex-vessel core melt debris by top flooding. Several experimental programs, including the OECD MACE, MCCI-1, and the current MCCI-2 program, have investigated core-concrete interactions and debris cooling of ex-vessel core melts. As part of the OECD programs, the CORQUENCH computer model was developed based on phenomena identified from the experiments. Predictions by CORQUENCH have previously been compared against experiments and have also been extrapolated to reactor scale. The current study applied statistical techniques to investigate the importance of initial system parameters and cooling phenomena in CORQUENCH 3.01 on the accident progression of ex-vessel core melts. The purpose of this sensitivity study is to identify parameters that are of major importance, any code peculiarities over the range of inputs, and where modeling improvements may produce the most gain in prediction accuracy. The sensitivity studies were carried out over a range of input conditions, in 1-D and 2-D geometries, and for two concrete compositions. In terms of initial system parameters, the melt height had the most importance on concrete ablation and melt coolability. With respect to cooling phenomena, the amount of melt entrainment through the crust had the most importance on concrete ablation and melt coolability. (author)

  3. Integrated conjugate heat transfer analysis method for in-vessel retention with external reactor vessel cooling - 15477

    International Nuclear Information System (INIS)

    Park, J.W.; Bae, J.H.; Seol, W.C.

    2015-01-01

    An integrated conjugate heat transfer analysis method for the thermal integrity of a reactor vessel under external reactor vessel cooling conditions is developed to resolve light metal layer focusing effect issue. The method calculates steady-state 3-dimensional temperature distribution of a reactor vessel using coupled conjugate heat transfer between in-vessel 3-layered stratified corium (metallic pool, oxide pool and heavy metal) and polar-angle dependent boiling heat transfer at the outer surface of a reactor vessel. The 3-layer corium heat transfer model is utilizing lumped-parameter thermal-resistance circuit method and ex-vessel boiling regimes are parametrically considered. The thermal integrity of a reactor vessel is addressed in terms of un-molten thickness profile. The vessel 3-dimensional heat conduction is validated against a commercial code. It is found that even though the internal heat flux from the metal layer goes far beyond critical heat flux (CHF) the heat flux from the outermost nodes of the vessel may be maintained below CHF due to massive vessel heat diffusion. The heat diffusion throughout the vessel is more pronounced for relatively low heat generation rate in an oxide pool. Parametric calculations are performed considering thermal conditions such as peak heat flux from a light metal layer, heat generation in an oxide pool and external boiling conditions. The major finding is that the most crucial factor for success of in-vessel retention is not the mass of the molten light metal above the oxide pool but the heat generation rate inside the oxide pool and the 3-dimensional vessel heat transfer provides a much larger minimum vessel wall thickness. (authors)

  4. Low Cost Integrated Navigation System for Unmanned Vessel

    Directory of Open Access Journals (Sweden)

    Yang Changsong

    2017-11-01

    Full Text Available Large errors of low-cost MEMS inertial measurement unit (MIMU lead to huge navigation errors, even wrong navigation information. An integrated navigation system for unmanned vessel is proposed. It consists of a low-cost MIMU and Doppler velocity sonar (DVS. This paper presents an integrated navigation method, to improve the performance of navigation system. The integrated navigation system is tested using simulation and semi-physical simulation experiments, whose results show that attitude, velocity and position accuracy has improved awfully, giving exactly accurate navigation results. By means of the combination of low-cost MIMU and DVS, the proposed system is able to overcome fast drift problems of the low cost IMU.

  5. ALICE HMPID Radiator Vessel

    CERN Document Server

    2003-01-01

    View of the radiator vessels of the ALICE/HMPID mounted on the support frame. Each HMPID module is equipped with 3 indipendent radiator vessels made out of neoceram and fused silica (quartz) windows glued together. The spacers inside the vessel are needed to stand the hydrostatic pressure. http://alice-hmpid.web.cern.ch/alice-hmpid

  6. Fully automatic algorithm for the analysis of vessels in the angiographic image of the eye fundus

    Directory of Open Access Journals (Sweden)

    Koprowski Robert

    2012-06-01

    Full Text Available Abstract Background The available scientific literature contains descriptions of manual, semi-automated and automated methods for analysing angiographic images. The presented algorithms segment vessels calculating their tortuosity or number in a given area. We describe a statistical analysis of the inclination of the vessels in the fundus as related to their distance from the center of the optic disc. Methods The paper presents an automated method for analysing vessels which are found in angiographic images of the eye using a Matlab implemented algorithm. It performs filtration and convolution operations with suggested masks. The result is an image containing information on the location of vessels and their inclination angle in relation to the center of the optic disc. This is a new approach to the analysis of vessels whose usefulness has been confirmed in the diagnosis of hypertension. Results The proposed algorithm analyzed and processed the images of the eye fundus using a classifier in the form of decision trees. It enabled the proper classification of healthy patients and those with hypertension. The result is a very good separation of healthy subjects from the hypertensive ones: sensitivity - 83%, specificity - 100%, accuracy - 96%. This confirms a practical usefulness of the proposed method. Conclusions This paper presents an algorithm for the automatic analysis of morphological parameters of the fundus vessels. Such an analysis is performed during fluorescein angiography of the eye. The presented algorithm automatically calculates the global statistical features connected with both tortuosity of vessels and their total area or their number.

  7. Blood Vessel Extraction in Color Retinal Fundus Images with Enhancement Filtering and Unsupervised Classification

    Directory of Open Access Journals (Sweden)

    Zafer Yavuz

    2017-01-01

    Full Text Available Retinal blood vessels have a significant role in the diagnosis and treatment of various retinal diseases such as diabetic retinopathy, glaucoma, arteriosclerosis, and hypertension. For this reason, retinal vasculature extraction is important in order to help specialists for the diagnosis and treatment of systematic diseases. In this paper, a novel approach is developed to extract retinal blood vessel network. Our method comprises four stages: (1 preprocessing stage in order to prepare dataset for segmentation; (2 an enhancement procedure including Gabor, Frangi, and Gauss filters obtained separately before a top-hat transform; (3 a hard and soft clustering stage which includes K-means and Fuzzy C-means (FCM in order to get binary vessel map; and (4 a postprocessing step which removes falsely segmented isolated regions. The method is tested on color retinal images obtained from STARE and DRIVE databases which are available online. As a result, Gabor filter followed by K-means clustering method achieves 95.94% and 95.71% of accuracy for STARE and DRIVE databases, respectively, which are acceptable for diagnosis systems.

  8. Study on prediction model of irradiation embrittlement for reactor pressure vessel steel

    International Nuclear Information System (INIS)

    Wang Rongshan; Xu Chaoliang; Huang Ping; Liu Xiangbing; Ren Ai; Chen Jun; Li Chengliang

    2014-01-01

    The study on prediction model of irradiation embrittlement for reactor pres- sure vessel (RPV) steel is an important method for long term operation. According to the deep analysis of the previous prediction models developed worldwide, the drawbacks of these models were given and a new irradiation embrittlement prediction model PMIE-2012 was developed. A corresponding reliability assessment was carried out by irradiation surveillance data. The assessment results show that the PMIE-2012 have a high reliability and accuracy on irradiation embrittlement prediction. (authors)

  9. Vessel bifurcation localization based on intraoperative three-dimensional ultrasound and catheter path for image-guided catheter intervention of oral cancers.

    Science.gov (United States)

    Luan, Kuan; Ohya, Takashi; Liao, Hongen; Kobayashi, Etsuko; Sakuma, Ichiro

    2013-03-01

    We present a method to localize intraoperative target vessel bifurcations under bones for ultrasound (US) image-guided catheter interventions. A catheter path is recorded to acquire skeletons for the target vessel bifurcations that cannot be imaged by intraoperative US. The catheter path is combined with the centerlines of the three-dimensional (3D) US image to construct a preliminary skeleton. Based on the preliminary skeleton, the orientations of target vessels are determined by registration with the preoperative image and the bifurcations were localized by computing the vessel length. An accurate intraoperative vessel skeleton is obtained for correcting the preoperative image to compensate for vessel deformation. A reality check of the proposed method was performed in a phantom experiment. Reasonable results were obtained. The in vivo experiment verified the clinical workflow of the proposed method in an in vivo environment. The accuracy of the centerline length of the vessel for localizing the target artery bifurcation was 2.4mm. These results suggest that the proposed method can allow the catheter tip to stop at the target artery bifurcations and enter into the target arteries. This method can be applied for virtual reality-enhanced image-guided catheter intervention of oral cancers. Copyright © 2013 Elsevier Ltd. All rights reserved.

  10. The diagnosis accuracy and safety of 99Tcm-MIBI myocardial perfusion imaging-a retrospective multicenter study

    International Nuclear Information System (INIS)

    Wang Rongfu; Qiu Yanli; Wang Liqin

    2012-01-01

    Objective: To evaluate the diagnostic accuracy and safety of 99 Tc m -MIBI MPI by retrospectively analyzing data from this multicenter study. Methods: Participating centers included six hospitals: Peking University First Hospital, Beijing Fuwai Hospital of Chinese Academy of Medical Science and Peking Union Medical College, Anzhen Hospital of Capital Medical University, Beijing Hospital of Health Ministry, Beijing Tongren Hospital of Capital Medical University and Peking University People's Hospital. According to the inclusion and exclusion criteria, 500 subjects (335 male, 165 female, mean age (60.1 ±11.1) years) who underwent MPI between April 1998 and April 2006 were enrolled. All subjects were investigated with stress/rest MPI and CAG within 1 month. Stress test was performed with bicycle ergometry or with intravenous dipyridamole, adenosine or ATP. Perfusion defects on MPI were allocated to corresponding coronary arteries. During the stress and imaging period,any discomfort or symptoms were recorded. Coronary stenosis with ≥ 50% luminal narrowing was considered significant in CAG and taken as the gold standard. 99 Tc m -MIBI MPI results for the number of stenosed vessels, stenotic severity and coronary artery allocation were compared using χ 2 test. Results: There were 280 subjects that underwent exercise stress tests and the remaining 220 received pharmacological stress tests (117 adenosine, 32 dipyridamole, 71 ATP). Two hundred and forty-nine patients had significant coronary stenosis and 251 had normal CAG. Out of the 249 patients with positive CAG results, 101 had one-vessel, 66 had two-vessel and 82 had three-vessel disease. Significant stenosis of the LAD was present in 205 patients, 144 had RCA stenosis and 130 had stenosis of the LCX. The sensitivity,specificity, accuracy, positive predictive and negative predictive values of MPI for detection of coronary artery disease were 65.1% (162/249), 81.3% (204/251), 73.2% (366/500), 77.5% (162

  11. Reactor vessel sealing plug

    International Nuclear Information System (INIS)

    Dooley, R.A.

    1986-01-01

    This invention relates to an apparatus and method for sealing the cold leg nozzles of a nuclear reactor pressure vessel from a remote location during maintenance and inspection of associated steam generators and pumps while the pressure vessel and refueling canal are filled with water. The apparatus includes a sealing plug for mechanically sealing the cold leg nozzle from the inside of a reactor pressure vessel. The sealing plugs include a primary and a secondary O-ring. An installation tool is suspended within the reactor vessel and carries the sealing plug. The tool telescopes to insert the sealing plug within the cold leg nozzle, and to subsequently remove the plug. Hydraulic means are used to activate the sealing plug, and support means serve to suspend the installation tool within the reactor vessel during installation and removal of the sealing plug

  12. Accuracy analysis of hybrid parallel robot for the assembling of ITER

    Energy Technology Data Exchange (ETDEWEB)

    Wang Yongbo [Institute of Mechatronics and Virtual Engineering, Lappeenranta University of Technology, Skinnarilankatu 34, 53850 Lappeenranta (Finland); The State Key Laboratory of Mechanical Transmission, Chongqing University (China); Pessi, Pekka [Institute of Mechatronics and Virtual Engineering, Lappeenranta University of Technology, Skinnarilankatu 34, 53850 Lappeenranta (Finland); Wu Huapeng [Institute of Mechatronics and Virtual Engineering, Lappeenranta University of Technology, Skinnarilankatu 34, 53850 Lappeenranta (Finland)], E-mail: huapeng@lut.fi; Handroos, Heikki [Institute of Mechatronics and Virtual Engineering, Lappeenranta University of Technology, Skinnarilankatu 34, 53850 Lappeenranta (Finland)

    2009-06-15

    This paper presents a novel mobile parallel robot, which is able to carry welding and machining processes from inside the international thermonuclear experimental reactor (ITER) vacuum vessel (VV). The kinematics design of the robot has been optimized for ITER access. To improve the accuracy of the parallel robot, the errors caused by the stiffness and manufacture process have to be compensated or limited to a minimum value. In this paper kinematics errors and stiffness modeling are given. The simulation results are presented.

  13. Accuracy analysis of hybrid parallel robot for the assembling of ITER

    International Nuclear Information System (INIS)

    Wang Yongbo; Pessi, Pekka; Wu Huapeng; Handroos, Heikki

    2009-01-01

    This paper presents a novel mobile parallel robot, which is able to carry welding and machining processes from inside the international thermonuclear experimental reactor (ITER) vacuum vessel (VV). The kinematics design of the robot has been optimized for ITER access. To improve the accuracy of the parallel robot, the errors caused by the stiffness and manufacture process have to be compensated or limited to a minimum value. In this paper kinematics errors and stiffness modeling are given. The simulation results are presented.

  14. Noninvasive identification of left main and triple vessel coronary artery disease using dipyridamole thallium scintigraphy

    International Nuclear Information System (INIS)

    Chikamori, Taishiro; Doi, Yoshinori; Yonezawa, Yoshihiro; Yamada, Mitsutoshi; Seo, Hiromi; Kawai, Kazuya; Yabe, Toshikazu; Ozawa, Toshio

    1993-01-01

    The diagnostic value of dipyridamole thallium scintigraphy for the noninvasive identification of left main (LM) and triple vessel (TV) coronary artery disease (CAD) was evaluated in 615 consecutive patients with known or suspected CAD. One hundred thirty-nine patients had LM or TVCAD; the remaining 476 patients had limited CAD (double vessel CAD in 112, single vessel CAD in 235, insignificant lesions in 129). Patients with LM or TVCAD, compared to those with limited CAD, had a higher incidence of diffuse slow washout (58 vs 20%, p<0.0001), extensive fixed defects (21 vs 6%, p<0.0001) and extensive reversible defects (32 vs 8%, p<0.0001). During dipyridamole loading, the incidence of chest pain was higher (65 vs 41%, p<0.0001), and the magnitude of ST depression was greater (0.16±0.14 vs 0.04±0.07 mV, p<0.001) in patients with LM or TVCAD than in those with limited CAD. Stepwise discriminant analysis using scintigraphic imaging achieved a sensitivity of 69%, a specificity of 79%, and an accuracy of 77% for diagnosing patients with LM or TVCAD. After including clinical markers of ischemia during dipyridamole loading, multivariate analysis revealed an improved diagnosis with a sensitivity of 71%, a specificity of 85%, and an accuracy of 82%. These results clearly show the usefulness of scintigraphic imaging as well as the significance of careful assessment of clinical markers of ischemia during dipyridamole loading for the noninvasive identification of LM and TVCAD. (author)

  15. Comparison of vascular width and accuracy of subjective assessment of pulmonary flow X-ray films of children with left-right shunt

    International Nuclear Information System (INIS)

    Hegenbarth, R.; Toeroek, M.; Hannover Medizinische Hochschule

    1985-01-01

    The authors established a comparative relationship between accuracy of measurement of pulmonary flow and extent of vascular widening in 72 children with Left-Right shunt vitiae; this accuracy of pulmonary flow measurement had been subjectively estimated by 4 investigators without knowing the diagnosis and in comparison to the haemodynamic values (percentage of correct findings). The following procedure was adopted: In a control group of 143 healthy children, we first determined the vascular diameter of the right descending pulmonary artery, of the right upper lobal vein, and of the peripheral vessels in the upper and lower pulmonary fields, at an accurately defined distance from the point of the hilus, and compared with the vascular diameters of the children with left-right shunt, employing the method of discrimination analysis. Comparison of the judgement by the 4 investigators with the degree of increase of the vascular diameters showed an accuracy of 65-100% if the right descending pulmonary artery became wider by 2.6 mm, and an accuracy of 79-95% if the mean vascular width in the right upper field increased by 0.7 mm. The accuracy was 83-94% if the mean vascular width in the right lower field increased by 0.6 mm. Statistical studies also showed that the judgement of the 4 investigators was influenced by different vessels. (orig.) [de

  16. Analytical and experimental vibration analysis of BWR pressure vessel internals

    International Nuclear Information System (INIS)

    Krutzik, N.; Schad, O.

    1975-01-01

    This report attempts to evaluate the validity as well as quality of several analytical methods in the light of presently available experimental data for the internals of pressure vessels of boiling-water-reactor-types. The experimental checks were performed after the numerical analysis was completed and showed the accuracy of the numerical results. The analytical investigations were done by finite element programmes - 2-dimensional as well as 3-dimensional, where the effect of the mass distribution with parts of virtual masses on the dynamic response could be studied in depth. The experimental data were collected at various different plants and with different mass correlations. Besides evaluating the dynamic characteristics of the components, tests were also performed to evaluate the vibrations of the pressure vessel relative to the main structure. After analysing extensive recorded data much better understanding of the response under a variety of loading- and boundary conditions could be gained. The comparison of the results of analytical studies with the experimental results made a broad qualitative evaluation possible. (Auth.)

  17. Reactor vessel stud closure system

    International Nuclear Information System (INIS)

    Spiegelman, S.R.; Salton, R.B.; Beer, R.W.; Malandra, L.J.; Cognevich, M.L.

    1982-01-01

    A quick-acting stud tensioner apparatus for enabling the loosening or tightening of a stud nut on a reactor vessel stud. The apparatus is adapted to engage the vessel stud by closing a gripper around an upper end of the vessel stud when the apparatus is seated on the stud. Upon lifting the apparatus, the gripper releases the vessel stud so that the apparatus can be removed

  18. Containment vessel drain system

    Science.gov (United States)

    Harris, Scott G.

    2018-01-30

    A system for draining a containment vessel may include a drain inlet located in a lower portion of the containment vessel. The containment vessel may be at least partially filled with a liquid, and the drain inlet may be located below a surface of the liquid. The system may further comprise an inlet located in an upper portion of the containment vessel. The inlet may be configured to insert pressurized gas into the containment vessel to form a pressurized region above the surface of the liquid, and the pressurized region may operate to apply a surface pressure that forces the liquid into the drain inlet. Additionally, a fluid separation device may be operatively connected to the drain inlet. The fluid separation device may be configured to separate the liquid from the pressurized gas that enters the drain inlet after the surface of the liquid falls below the drain inlet.

  19. Shear buckling of cylindrical vessels benchmark exercise

    International Nuclear Information System (INIS)

    Dostal, M; Austin, N.; Combescure, A.; Peano, A.; Angeloni, P.

    1987-01-01

    In Liquid Metal Fast Breeder Reactors (LMFBR) potential shear buckling failures of the primary vessel, induced through seismic excitations, have to be considered. The problem is particularly severe in pool type reactors due to their large size, radius of approximately 10 m, coupled with small wall thicknesses of 50 mm and less. The object of this paper is to provide a comparison of three different computer codes capable of performing buckling analyses and to demonstrate on practical problems the level of accuracy that may be expected in design analyses. Three computer codes were examined ABAQUS, CASTEM (INCA/BILBO) and NOVNL and the computer results were compared directly with experimental data and other commonly used empirical formula. The joint effort was co-ordinated through the CEC Working Group on Codes and Standards AG2. (orig./GL)

  20. Mobile nuclear reactor containment vessel

    International Nuclear Information System (INIS)

    Thompson, R.E.; Spurrier, F.R.; Jones, A.R.

    1978-01-01

    A containment vessel for use in mobile nuclear reactor installations is described. The containment vessel completely surrounds the entire primary system, and is located as close to the reactor primary system components as is possible in order to minimize weight. In addition to being designed to withstand a specified internal pressure, the containment vessel is also designed to maintain integrity as a containment vessel in case of a possible collision accident

  1. The pattern of renal vessels in live related potential donors pool. A multislice computed tomography angiography review

    International Nuclear Information System (INIS)

    Mishra, A.; Ehtuish, Ehtuish F.

    2006-01-01

    To assess the renal vessel anatomy, compare the findings with the perioperative findings, to determine the sensitivity of multislice computed tomography (CT) angiography in the work-up of live potential donors and to discuss and compare the results of the present study with the reported results using single slice CT, magnetic resonance (MRI) and conventional angiography (CA).Retrospective analysis of the angiographic data of 118 of prospective live related kidney donors was carried out from October 2004 to August 2005 at the National Organ Transplant Centre, Tripoli Central Hospital, Libya. All donors underwent renal angiography on multislice (16-slice) CT scan using 80 cc intravenous contrast with 1.25 mm slice thickness followed by maximum intensity projection (MIP) and volume rendering techniques (VRT) post-processing algorithms. The number of vessels, vessel bifurcation, vessel morphology and venous anatomy were analyzed and the findings were compared with the surgical findings. Multislice spiral CT angiography (MSCTA) showed clear delineation of the main renal arteries in all donors with detailed vessel morphology. The study revealed 100% sensitivity in detection of accessory renal vessels, with an overall incidence of 26.7%, which is the most common distribution in the parahilar region. The present study showed 100% sensitivity in the visualization and detection of main and accessory renal vessels. These results were comparable with conventional angiography which has so far been considered as the gold standard and were found superior in specificity and accuracy to the use of single slice CT (SSCT) and MR in the angiographic work-up of live renal donors. Due to improved detection of accessory vessels less than 2 mm in diameter, a higher incidence of aberrant vessels was seen on the right side as has been suggested so far. (author)

  2. Thermal Behavior of the Reactor Vessel Penetration Under External Vessel Cooling During a Severe Accident

    International Nuclear Information System (INIS)

    Kang, Kyoung-Ho; Park, Rae-Joon; Kim, Jong-Tae; Min, Byung-Tae; Lee, Ki-Young; Kim, Sang-Baik

    2004-01-01

    Experimental and analytical studies on the thermal behavior of reactor vessel penetration have been performed under external vessel cooling during a severe accident in the Korean next-generation reactor APR1400. Two types of tests, SUS-EXT and SUS-DRY with and without external vessel cooling, respectively, have been performed using sustained heating by an induction heater. Three tests have been carried out varying the cooling conditions at the vessel outer surface in the SUS-EXT tests. The experimental results have been thermally estimated using the LILAC computer code. The experimental results indicate that the inner surface of the vessel was ablated by the 45-mm thickness in the SUS-DRY test. Despite the total ablation of the welding material, the penetration was not ejected outside the vessel, which could be attributed to the thermal expansion of the penetration. Unlike the SUS-DRY test, the thickness of the ablation was ∼15 to 20 mm at most, so the welding was preserved in the SUS-EXT tests. It is concluded from the experimental results that the external vessel cooling highly affected the ablation configuration and the thermal behaviors of the vessel and the penetration. An increase in coolant mass flow rate from 0.047 to 0.152 kg/s had effects on the thermal behavior of the lower head vessel and penetration in the SUS-EXT tests. The LILAC analytical results on temperature distribution and ablation depth in the lower head vessel and penetration were very similar to the experimental results

  3. Automated vessel shadow segmentation of fovea-centered spectral-domain images from multiple OCT devices

    Science.gov (United States)

    Wu, Jing; Gerendas, Bianca S.; Waldstein, Sebastian M.; Simader, Christian; Schmidt-Erfurth, Ursula

    2014-03-01

    Spectral-domain Optical Coherence Tomography (SD-OCT) is a non-invasive modality for acquiring high reso- lution, three-dimensional (3D) cross sectional volumetric images of the retina and the subretinal layers. SD-OCT also allows the detailed imaging of retinal pathology, aiding clinicians in the diagnosis of sight degrading diseases such as age-related macular degeneration (AMD) and glaucoma.1 Disease diagnosis, assessment, and treatment requires a patient to undergo multiple OCT scans, possibly using different scanning devices, to accurately and precisely gauge disease activity, progression and treatment success. However, the use of OCT imaging devices from different vendors, combined with patient movement may result in poor scan spatial correlation, potentially leading to incorrect patient diagnosis or treatment analysis. Image registration can be used to precisely compare disease states by registering differing 3D scans to one another. In order to align 3D scans from different time- points and vendors using registration, landmarks are required, the most obvious being the retinal vasculature. Presented here is a fully automated cross-vendor method to acquire retina vessel locations for OCT registration from fovea centred 3D SD-OCT scans based on vessel shadows. Noise filtered OCT scans are flattened based on vendor retinal layer segmentation, to extract the retinal pigment epithelium (RPE) layer of the retina. Voxel based layer profile analysis and k-means clustering is used to extract candidate vessel shadow regions from the RPE layer. In conjunction, the extracted RPE layers are combined to generate a projection image featuring all candidate vessel shadows. Image processing methods for vessel segmentation of the OCT constructed projection image are then applied to optimize the accuracy of OCT vessel shadow segmentation through the removal of false positive shadow regions such as those caused by exudates and cysts. Validation of segmented vessel shadows uses

  4. Nuclear reactor vessel decontamination systems

    International Nuclear Information System (INIS)

    McGuire, P. J.

    1985-01-01

    There is disclosed in the present application, a decontamination system for reactor vessels. The system is operatable without entry by personnel into the contaminated vessel before the decontamination operation is carried out and comprises an assembly which is introduced into the vertical cylindrical vessel of the typical boiling water reactor through the open top. The assembly includes a circular track which is centered by guideways permanently installed in the reactor vessel and the track guides opposed pairs of nozzles through which water under very high pressure is directed at the wall for progressively cutting and sweeping a tenacious radioactive coating as the nozzles are driven around the track in close proximity to the vessel wall. The whole assembly is hoisted to a level above the top of the vessel by a crane, outboard slides on the assembly brought into engagement with the permanent guideways and the assembly progressively lowered in the vessel as the decontamination operation progresses. The assembly also includes a low pressure nozzle which forms a spray umbrella above the high pressure nozzles to contain radioactive particles dislodged during the decontamination

  5. What is cerebral small vessel disease?

    International Nuclear Information System (INIS)

    Onodera, Osamu

    2011-01-01

    An accumulating amount of evidence suggests that the white matter hyperintensities on T 2 weighted brain magnetic resonance imaging predict an increased risk of dementia and gait disturbance. This state has been proposed as cerebral small vessel disease, including leukoaraiosis, Binswanger's disease, lacunar stroke and cerebral microbleeds. However, the concept of cerebral small vessel disease is still obscure. To understand the cerebral small vessel disease, the precise structure and function of cerebral small vessels must be clarified. Cerebral small vessels include several different arteries which have different anatomical structures and functions. Important functions of the cerebral small vessels are blood-brain barrier and perivasucular drainage of interstitial fluid from the brain parenchyma. Cerebral capillaries and glial endfeet, take an important role for these functions. However, the previous pathological investigations on cerebral small vessels have focused on larger arteries than capillaries. Therefore little is known about the pathology of capillaries in small vessel disease. The recent discoveries of genes which cause the cerebral small vessel disease indicate that the cerebral small vessel diseases are caused by a distinct molecular mechanism. One of the pathological findings in hereditary cerebral small vessel disease is the loss of smooth muscle cells, which is an also well-recognized finding in sporadic cerebral small vessel disease. Since pericytes have similar character with the smooth muscle cells, the pericytes should be investigated in these disorders. In addition, the loss of smooth muscle cells may result in dysfunction of drainage of interstitial fluid from capillaries. The precise correlation between the loss of smooth muscle cells and white matter disease is still unknown. However, the function that is specific to cerebral small vessel may be associated with the pathogenesis of cerebral small vessel disease. (author)

  6. Massive the Higgs boson and the greatest hunt in science

    CERN Document Server

    Sample, Ian

    2013-01-01

    Now fully updated -- this is the dramatic and gripping account of the greatest scientific discovery of our time. In the early 1960s, three groups of physicists, working independently in different countries, stumbled upon an idea that would change physics and fuel the imagination of scientists for decades. That idea was the Higgs boson -- to find it would be to finally understand the origins of mass -- the last building block of life itself. Now, almost 50 years later, that particle has finally been discovered.

  7. A stochastic-bayesian model for the fracture probability of PWR pressure vessels

    Energy Technology Data Exchange (ETDEWEB)

    Francisco, Alexandre S.; Duran, Jorge Alberto R., E-mail: afrancisco@metal.eeimvr.uff.br, E-mail: duran@metal.eeimvr.uff.br [Universidade Federal Fluminense (UFF), Volta Redonda, RJ (Brazil). Dept. de Engenharia Mecanica

    2013-07-01

    Fracture probability of pressure vessels containing cracks can be obtained by methodologies of easy understanding, which require a deterministic treatment, complemented by statistical methods. However, more accurate results are required, methodologies need to be better formulated. This paper presents a new methodology to address this problem. First, a more rigorous methodology is obtained by means of the relationship of probability distributions that model crack incidence and nondestructive inspection efficiency using the Bayes' theorem. The result is an updated crack incidence distribution. Further, the accuracy of the methodology is improved by using a stochastic model for the crack growth. The stochastic model incorporates the statistical variability of the crack growth process, combining the stochastic theory with experimental data. Stochastic differential equations are derived by the randomization of empirical equations. From the solution of this equation, a distribution function related to the crack growth is derived. The fracture probability using both probability distribution functions is in agreement with theory, and presents realistic value for pressure vessels. (author)

  8. A stochastic-bayesian model for the fracture probability of PWR pressure vessels

    International Nuclear Information System (INIS)

    Francisco, Alexandre S.; Duran, Jorge Alberto R.

    2013-01-01

    Fracture probability of pressure vessels containing cracks can be obtained by methodologies of easy understanding, which require a deterministic treatment, complemented by statistical methods. However, more accurate results are required, methodologies need to be better formulated. This paper presents a new methodology to address this problem. First, a more rigorous methodology is obtained by means of the relationship of probability distributions that model crack incidence and nondestructive inspection efficiency using the Bayes' theorem. The result is an updated crack incidence distribution. Further, the accuracy of the methodology is improved by using a stochastic model for the crack growth. The stochastic model incorporates the statistical variability of the crack growth process, combining the stochastic theory with experimental data. Stochastic differential equations are derived by the randomization of empirical equations. From the solution of this equation, a distribution function related to the crack growth is derived. The fracture probability using both probability distribution functions is in agreement with theory, and presents realistic value for pressure vessels. (author)

  9. Segmentation of retinal blood vessels for detection of diabetic retinopathy: A review

    Directory of Open Access Journals (Sweden)

    Rezty Amalia Aras

    2016-05-01

    Full Text Available Diabetic detinopathy (DR is effect of diabetes mellitus to the human vision that is the major cause of blindness. Early diagnosis of DR is an important requirement in diabetes treatment. Retinal fundus image is commonly used to observe the diabetic retinopathy symptoms. It can present retinal features such as blood vessel and also capture the pathologies which may lead to DR. Blood vessel is one of retinal features which can show the retina pathologies. It can be extracted from retinal image by image processing with following stages: pre-processing, segmentation, and post-processing. This paper contains a review of public retinal image dataset and several methods from various conducted researches. All discussed methods are applicable to each researcher cases. There is no further analysis to conclude the best method which can be used for general cases. However, we suggest morphological and multiscale method that gives the best accuracy in segmentation.

  10. Nuclear reactor vessel inspection apparatus

    International Nuclear Information System (INIS)

    Blackstone, E.G.; Lofy, R.A.; Williams, L.P.

    1979-01-01

    Apparatus for the in situ inspection of a nuclear reactor vessel to detect the location and character of flaws in the walls of the vessel, in the welds joining the various sections of the vessel, in the welds joining attachments such as nozzles, elbows and the like to the reactor vessel and in such attachments wherein an inspection head carrying one or more ultrasonic transducers follows predetermined paths in scanning the various reactor sections, welds and attachments

  11. Stability, structure and scale: improvements in multi-modal vessel extraction for SEEG trajectory planning.

    Science.gov (United States)

    Zuluaga, Maria A; Rodionov, Roman; Nowell, Mark; Achhala, Sufyan; Zombori, Gergely; Mendelson, Alex F; Cardoso, M Jorge; Miserocchi, Anna; McEvoy, Andrew W; Duncan, John S; Ourselin, Sébastien

    2015-08-01

    Brain vessels are among the most critical landmarks that need to be assessed for mitigating surgical risks in stereo-electroencephalography (SEEG) implantation. Intracranial haemorrhage is the most common complication associated with implantation, carrying significantly associated morbidity. SEEG planning is done pre-operatively to identify avascular trajectories for the electrodes. In current practice, neurosurgeons have no assistance in the planning of electrode trajectories. There is great interest in developing computer-assisted planning systems that can optimise the safety profile of electrode trajectories, maximising the distance to critical structures. This paper presents a method that integrates the concepts of scale, neighbourhood structure and feature stability with the aim of improving robustness and accuracy of vessel extraction within a SEEG planning system. The developed method accounts for scale and vicinity of a voxel by formulating the problem within a multi-scale tensor voting framework. Feature stability is achieved through a similarity measure that evaluates the multi-modal consistency in vesselness responses. The proposed measurement allows the combination of multiple images modalities into a single image that is used within the planning system to visualise critical vessels. Twelve paired data sets from two image modalities available within the planning system were used for evaluation. The mean Dice similarity coefficient was 0.89 ± 0.04, representing a statistically significantly improvement when compared to a semi-automated single human rater, single-modality segmentation protocol used in clinical practice (0.80 ± 0.03). Multi-modal vessel extraction is superior to semi-automated single-modality segmentation, indicating the possibility of safer SEEG planning, with reduced patient morbidity.

  12. Limitations of quantitative photoacoustic measurements of blood oxygenation in small vessels

    International Nuclear Information System (INIS)

    Sivaramakrishnan, Mathangi; Maslov, Konstantin; Zhang, Hao F; Stoica, George; Wang, Lihong V

    2007-01-01

    We investigate the feasibility of obtaining accurate quantitative information, such as local blood oxygenation level (sO 2 ), with a spatial resolution of about 50 μm from spectral photoacoustic (PA) measurements. The optical wavelength dependence of the peak values of the PA signals is utilized to obtain the local blood oxygenation level. In our in vitro experimental models, the PA signal amplitude is found to be linearly proportional to the blood optical absorption coefficient when using ultrasonic transducers with central frequencies high enough such that the ultrasonic wavelengths are shorter than the light penetration depth into the blood vessels. For an optical wavelength in the 578-596 nm region, with a transducer central frequency that is above 25 MHz, the sensitivity and accuracy of sO 2 inversion is shown to be better than 4%. The effect of the transducer focal position on the accuracy of quantifying blood oxygenation is found to be negligible. In vivo oxygenation measurements of rat skin microvasculature yield results consistent with those from in vitro studies, although factors specific to in vivo measurements, such as the spectral dependence of tissue optical attenuation, dramatically affect the accuracy of sO 2 quantification in vivo

  13. Penicillin: the medicine with the greatest impact on therapeutic outcomes.

    Science.gov (United States)

    Kardos, Nelson; Demain, Arnold L

    2011-11-01

    The principal point of this paper is that the discovery of penicillin and the development of the supporting technologies in microbiology and chemical engineering leading to its commercial scale production represent it as the medicine with the greatest impact on therapeutic outcomes. Our nomination of penicillin for the top therapeutic molecule rests on two lines of evidence concerning the impact of this event: (1) the magnitude of the therapeutic outcomes resulting from the clinical application of penicillin and the subsequent widespread use of antibiotics and (2) the technologies developed for production of penicillin, including both microbial strain selection and improvement plus chemical engineering methods responsible for successful submerged fermentation production. These became the basis for production of all subsequent antibiotics in use today. These same technologies became the model for the development and production of new types of bioproducts (i.e., anticancer agents, monoclonal antibodies, and industrial enzymes). The clinical impact of penicillin was large and immediate. By ushering in the widespread clinical use of antibiotics, penicillin was responsible for enabling the control of many infectious diseases that had previously burdened mankind, with subsequent impact on global population demographics. Moreover, the large cumulative public effect of the many new antibiotics and new bioproducts that were developed and commercialized on the basis of the science and technology after penicillin demonstrates that penicillin had the greatest therapeutic impact event of all times. © Springer-Verlag 2011

  14. Comparison of exercise perfusion and ventricular function imaging: an analysis of factors affecting the diagnostic accuracy of each technique

    International Nuclear Information System (INIS)

    Osbakken, M.D.; Okada, R.D.; Boucher, C.A.; Strauss, H.W.; Pohost, G.M.

    1984-01-01

    Exercise thallium-201 perfusion scans and gated equilibrium blood pool scans were performed in 120 catheterized patients with a chest pain syndrome. Eighty-six patients had coronary artery disease and 34 patients did not. The effects of gender, propranolol, exercise level, exercise ischemia, history of typical angina, history of previous myocardial infarction, electrocardiographic Q waves, number of diseases vessels and extent of coronary artery obstruction on diagnostic accuracy were evaluated. Thallium scans and anginal history were less sensitive for detecting coronary disease in women (men: thallium 79%; angina 77%; women: 54 and 46%, respectively; p less than 0.05). Exercise level did not significantly affect the diagnostic accuracy of either scan. Thallium and gated scans were both highly sensitive (95%) in detecting disease in 20 patients with a prior myocardial infarction, angina and a positive electrocardiogram. The sensitivity of the thallium scan significantly decreased as the number of diseased vessels decreased. Both thallium and gated scans were less frequently positive in patients with atypical angina or no Q waves, but were not significantly influenced by electrocardiographic ischemia. The sensitivity and specificity of both scans were low in 57 patients with the combination of atypical angina, no history of infarction and equivocal stress electrocardiogram thallium. When stress thallium scan evaluation included the electrocardiogram and thallium scan interpretation, the diagnostic accuracy was 81%. When all the information from gated scans (wall motion, ejection fraction, pulmonary blood volume) was combined for final gated scan evaluation, the diagnostic accuracy was 83%. When electrocardiographic data were added to all three gated scan variables, diagnostic accuracy was 77%

  15. Flexible Composite-Material Pressure Vessel

    Science.gov (United States)

    Brown, Glen; Haggard, Roy; Harris, Paul A.

    2003-01-01

    A proposed lightweight pressure vessel would be made of a composite of high-tenacity continuous fibers and a flexible matrix material. The flexibility of this pressure vessel would render it (1) compactly stowable for transport and (2) more able to withstand impacts, relative to lightweight pressure vessels made of rigid composite materials. The vessel would be designed as a structural shell wherein the fibers would be predominantly bias-oriented, the orientations being optimized to make the fibers bear the tensile loads in the structure. Such efficient use of tension-bearing fibers would minimize or eliminate the need for stitching and fill (weft) fibers for strength. The vessel could be fabricated by techniques adapted from filament winding of prior composite-material vessels, perhaps in conjunction with the use of dry film adhesives. In addition to the high-bias main-body substructure described above, the vessel would include a low-bias end substructure to complete coverage and react peak loads. Axial elements would be overlaid to contain damage and to control fiber orientation around side openings. Fiber ring structures would be used as interfaces for connection to ancillary hardware.

  16. Ionizing radiations and blood vessels

    International Nuclear Information System (INIS)

    Vorob'ev, E.I.; Stepanov, R.P.

    1985-01-01

    Data on phenomeology of radiation changes of blood vessels are systemized and the authors' experience is generalyzed. A critical analysis of modern conceptions on processes resulting in vessel structure damage after irradiation, is given. Special attention is paid to reparation and compensation of radiation injury of vessels

  17. Acrylic vessel cleaning tests

    International Nuclear Information System (INIS)

    Earle, D.; Hahn, R.L.; Boger, J.; Bonvin, E.

    1997-01-01

    The acrylic vessel as constructed is dirty. The dirt includes blue tape, Al tape, grease pencil, gemak, the glue or residue form these tapes, finger prints and dust of an unknown composition but probably mostly acrylic dust. This dirt has to be removed and once removed, the vessel has to be kept clean or at least to be easily cleanable at some future stage when access becomes much more difficult. The authors report on the results of a series of tests designed: (a) to prepare typical dirty samples of acrylic; (b) to remove dirt stuck to the acrylic surface; and (c) to measure the optical quality and Th concentration after cleaning. Specifications of the vessel call for very low levels of Th which could come from tape residues, the grease pencil, or other sources of dirt. This report does not address the concerns of how to keep the vessel clean after an initial cleaning and during the removal of the scaffolding. Alconox is recommended as the cleaner of choice. This acrylic vessel will be used in the Sudbury Neutrino Observatory

  18. Development of PWR pressure vessel steels

    International Nuclear Information System (INIS)

    Druce, S.; Edwards, B.

    1982-01-01

    Requirements to be met by vessel steels for pressurized water reactors are analyzed. Chemicat composition of low-alloyed steels, mechanical properties of sheets and forgings made of these steels and changes in the composition and properties over the wall thickness of the reactor vessel are presented. Problems of the vessel manufacturing including welding and heat treatment processes of sheets and forgings are considered. Special attention is paid to steel embrittlement during vessel fabrication and operation (radiation embrittlement, thermal embrittlement). The role of non-metal inclusions and their effect on anisotropy of fracture toughness is discussed. Possible developments of vessel steels and procedures for producing reactor vessels are reviewed

  19. Development of PWR pressure vessel steels

    Energy Technology Data Exchange (ETDEWEB)

    Druce, S.; Edwards, B.

    1982-01-01

    Requirements to be met by vessel steels for pressurized water reactors are analyzed. Chemicat composition of low-alloyed steels, mechanical properties of sheets and forgings made of these steels and changes in the composition and properties over the wall thickness of the reactor vessel are presented. Problems of the vessel manufacturing including welding and heat treatment processes of sheets and forgings are considered. Special attention is paid to steel embrittlement during vessel fabrication and operation (radiation embrittlement, thermal embrittlement). The role of non-metal inclusions and their effect on anisotropy of fracture toughness is discussed. Possible developments of vessel steels and procedures for producing reactor vessels are reviewed.

  20. Clay Corner: Recreating Chinese Bronze Vessels.

    Science.gov (United States)

    Gamble, Harriet

    1998-01-01

    Presents a lesson where students make faux Chinese bronze vessels through slab or coil clay construction after they learn about the history, function, and design of these vessels. Utilizes a variety of glaze finishes in order to give the vessels an aged look. Gives detailed guidelines for creating the vessels. (CMK)

  1. Gammatography of thick lead vessels

    International Nuclear Information System (INIS)

    Raghunath, V.M.; Bhatnagar, P.K.; Sundaram, V.M.

    1979-01-01

    Radiography, scintillation and GM counting and dose measurements using ionisation chamber equipment are commonly used for detecting flaws/voids in materials. The first method is mostly used for steel vessels and to a lesser extent thin lead vessels also and is essentially qualitative. Dose measuring techniques are used for very thick and large lead vessels for which high strength radioactive sources are required, with its inherent handling problems. For vessels of intermediate thicknesses, it is ideal to use a small strength source and a GM or scintillation counter assembly. At the Reactor Research Centre, Kalpakkam, such a system was used for checking three lead vessels of thicknesses varying from 38mm to 65mm. The tolerances specified were +- 4% variation in lead thickness. The measurements also revealed the non concentricity of one vessel which had a thickness varying from 38mm to 44mm. The second vessel was patently non-concentric and the dimensional variation was truly reproduced in the measurements. A third vessel was fabricated with careful control of dimensions and the measurements exhibited good concentricity. Small deviations were observed, attributable to imperfect bondings between steel and lead. This technique has the following advantages: (a) weaker sources used result in less handling problems reducing the personnel exposures considerably; (b) the sensitivity of the instrument is quite good because of better statistics; (c) the time required for scanning a small vessel is more, but a judicious use of a scintillometer for initial fast scan will help in reducing the total scanning time; (d) this method can take advantage of the dimensional variations themselves to get the calibration and to estimate the deviations from specified tolerances. (auth.)

  2. Smooth muscle cell recruitment to lymphatic vessels requires PDGFB and impacts vessel size but not identity.

    Science.gov (United States)

    Wang, Yixin; Jin, Yi; Mäe, Maarja Andaloussi; Zhang, Yang; Ortsäter, Henrik; Betsholtz, Christer; Mäkinen, Taija; Jakobsson, Lars

    2017-10-01

    Tissue fluid drains through blind-ended lymphatic capillaries, via smooth muscle cell (SMC)-covered collecting vessels into venous circulation. Both defective SMC recruitment to collecting vessels and ectopic recruitment to lymphatic capillaries are thought to contribute to vessel failure, leading to lymphedema. However, mechanisms controlling lymphatic SMC recruitment and its role in vessel maturation are unknown. Here, we demonstrate that platelet-derived growth factor B (PDGFB) regulates lymphatic SMC recruitment in multiple vascular beds. PDGFB is selectively expressed by lymphatic endothelial cells (LECs) of collecting vessels. LEC-specific deletion of Pdgfb prevented SMC recruitment causing dilation and failure of pulsatile contraction of collecting vessels. However, vessel remodelling and identity were unaffected. Unexpectedly, Pdgfb overexpression in LECs did not induce SMC recruitment to capillaries. This was explained by the demonstrated requirement of PDGFB extracellular matrix (ECM) retention for lymphatic SMC recruitment, and the low presence of PDGFB-binding ECM components around lymphatic capillaries. These results demonstrate the requirement of LEC-autonomous PDGFB expression and retention for SMC recruitment to lymphatic vessels, and suggest an ECM-controlled checkpoint that prevents SMC investment of capillaries, which is a common feature in lymphedematous skin. © 2017. Published by The Company of Biologists Ltd.

  3. School Issues Under [Section] 504 and the ADA: The Latest and Greatest.

    Science.gov (United States)

    Aleman, Steven R.

    This paper highlights recent guidance and rulings from the Office of Civil Rights (OCR) of interest to administrators, advocates, and attorneys. It is a companion piece to Student Issues on SectionNB504/ADA: The Latest and Greatest. Compliance with SectionNB504 and the Americans with Disabilities Act (ADA) continues to involve debate and dialog on…

  4. Americium behaviour in plastic vessels

    Energy Technology Data Exchange (ETDEWEB)

    Legarda, F.; Herranz, M. [Departamento de Ingenieria Nuclear y Mecanica de Fluidos, Escuela Tecnica Superior de Ingenieria de Bilbao, Universidad del Pais Vasco (UPV/EHU), Alameda de Urquijo s/n, 48013 Bilbao (Spain); Idoeta, R., E-mail: raquel.idoeta@ehu.e [Departamento de Ingenieria Nuclear y Mecanica de Fluidos, Escuela Tecnica Superior de Ingenieria de Bilbao, Universidad del Pais Vasco (UPV/EHU), Alameda de Urquijo s/n, 48013 Bilbao (Spain); Abelairas, A. [Departamento de Ingenieria Nuclear y Mecanica de Fluidos, Escuela Tecnica Superior de Ingenieria de Bilbao, Universidad del Pais Vasco (UPV/EHU), Alameda de Urquijo s/n, 48013 Bilbao (Spain)

    2010-07-15

    The adsorption of {sup 241}Am dissolved in water in different plastic storage vessels was determined. Three different plastics were investigated with natural and distilled waters and the retention of {sup 241}Am by these plastics was studied. The same was done by varying vessel agitation time, vessel agitation speed, surface/volume ratio of water in the vessels and water pH. Adsorptions were measured to be between 0% and 70%. The adsorption of {sup 241}Am is minimized with no water agitation, with PET or PVC plastics, and by water acidification.

  5. Americium behaviour in plastic vessels

    International Nuclear Information System (INIS)

    Legarda, F.; Herranz, M.; Idoeta, R.; Abelairas, A.

    2010-01-01

    The adsorption of 241 Am dissolved in water in different plastic storage vessels was determined. Three different plastics were investigated with natural and distilled waters and the retention of 241 Am by these plastics was studied. The same was done by varying vessel agitation time, vessel agitation speed, surface/volume ratio of water in the vessels and water pH. Adsorptions were measured to be between 0% and 70%. The adsorption of 241 Am is minimized with no water agitation, with PET or PVC plastics, and by water acidification.

  6. PWR vessel flaw distribution development

    International Nuclear Information System (INIS)

    Rosinski, S.T.; Kennedy, E.L.; Foulds, J.R.; Kinsman, K.M.

    1990-01-01

    This paper reports on PWR pressure vessels which operate under NRC rules and regulatory guides intended to prevent failure of the vessels. Plants failing to meet the operating criteria specified under these rules and regulations are required to analytically demonstrate fitness for service in order to continue operation. The initial flaw size or distribution of initial vessel flaws is a key input to the required vessel integrity analyses. However, the flaw distribution assumed in the development of the NRC Regulations and recommended for the plant specific analyses is potentially over-conservative. This is because the distribution is based on the limited amount of vessel inspection data available at the time the criteria were being developed and does not take full advantage of the more recent and reliable domestic vessel inspection results. The U.S. Department of Energy is funding an effort through Sandia National Laboratories to investigate the possibility of developing a new flaw distribution based on the increased amount and improved reliability of domestic vessel inspection data. Results of Phase I of the program indicate that state-of-the-art NDE systems' capabilities are sufficient for development of a new flaw distribution that could ultimately provide life extension benefits over the presently required operating practice

  7. Test of 6-in.-thick pressure vessels. Series 3: intermediate test vessel V-7

    International Nuclear Information System (INIS)

    Merkle, J.G.; Robinson, G.C.; Holz, P.P.; Smith, J.E.; Bryan, R.H.

    1976-08-01

    The test of intermediate test vessel V-7 was a crack-initiation fracture test of a 152-mm-thick (6-in.), 990-mm-OD (39-in.) vessel of ASTM A533, grade B, class 1 steel plate with a sharp outside surface flaw 457 mm (18 in.) long and about 135 mm (5.3 in.) deep. The vessel was heated to 91 0 C (196 0 F) and pressurized hydraulically until leakage through the flaw terminated the test at a peak pressure of 147 MPa (21,350 psi). Fracture toughness data obtained by testing precracked Charpy-V and compact-tension specimens machined from a prolongation of the cylindrical test shell were used in pretest analyses of the flawed vessel. The vessel, as expected, did not burst. Upon depressurization, the ruptured ligament closed so as to maintain static pressure without leakage at about 129 MPa

  8. Chemical methods for the use of niobium from pressure vessel cladding as a fast neutron dosimeter

    International Nuclear Information System (INIS)

    Karnani, Hari

    1986-08-01

    the steel samples from the cladding of a pressure vessel of an operating nuclear power reactor were obtained by scraping. The cladding material of the pressure vessel contained about 0.5 % niobium. It was desired to use the niobium as a dosimeter for estimating fast fluences at the pressure vessel. The weak radiation from the reaction product 93m Nb cannot be measured in the presence of other elements and interfering activities. A method was developed to separate niobium from other metals present; the concentration and yield of niobium were determined spectrophotometrically. The irradiated niobium was electrodeposited from aqueous solutions on copper discs. The amount of the deposited niobium was determined by a radiochemical method which makes use of its own radioactivity - measured with a liquid scintillation counter - and the known starting mass of niobium. It was possible to determine the deposited niobium masses (5 to 200 microgram) with a desired degree of accuracy. The absolute emission rate of X-rays could then be measured without any self-absorption or interference from other activities. The mass of niobium on each preparate and its X-ray emission rate, later on, were used as basic experimental data for the estimation of last neutron doses at the pressure vessel

  9. Hydrogen storage in insulated pressure vessels

    Energy Technology Data Exchange (ETDEWEB)

    Aceves, S.M.; Garcia-Villazana, O. [Lawrence Livermore National Lab., CA (United States)

    1998-08-01

    Insulated pressure vessels are cryogenic-capable pressure vessels that can be fueled with liquid hydrogen (LH{sub 2}) or ambient-temperature compressed hydrogen (CH{sub 2}). Insulated pressure vessels offer the advantages of liquid hydrogen tanks (low weight and volume), with reduced disadvantages (lower energy requirement for hydrogen liquefaction and reduced evaporative losses). This paper shows an evaluation of the applicability of the insulated pressure vessels for light-duty vehicles. The paper shows an evaluation of evaporative losses and insulation requirements and a description of the current analysis and experimental plans for testing insulated pressure vessels. The results show significant advantages to the use of insulated pressure vessels for light-duty vehicles.

  10. Earthquake-proof supporting structure in reactor vessel

    International Nuclear Information System (INIS)

    Sakurai, Akio; Sekine, Katsuhisa; Madokoro, Manabu; Katoono, Shin-ichi; Konno, Mutsuo; Suzuki, Takuro.

    1990-01-01

    Conventional earthquake-proof structure comprises a vessel vibration stopper integrated to a reactor vessel, powder for restricting the horizontal displacements, a safety vessel surrounds the outer periphery of the reactor vessel and a safety vessel vibration stopper integrated therewith, which are fixed to buildings. However, there was a problem that a great amount of stresses are generated in the base of the reactor vessel vibration stopper due to reaction of the powders which restrict thermal expansion. In order to remarkably reduce the reaction of the powers, powders are charged into a spaces formed between each of the reactor vessel vibration stopper, the safety vessel vibration stopper and the flexible member disposed between them. According to this constitution, the reactor vessel vibration stopper does not undergo a great reaction of the powers upon thermal expansion of the reactor vessel to moderate the generated stresses, maintain the strength and provide earthquake-proof supporting function. (N.H.)

  11. Pressure vessel for nuclear reactors

    International Nuclear Information System (INIS)

    1975-01-01

    The invention applies to a pressure vessel for nuclear reactors whose shell, made of cast metal segments, has a steel liner. This liner must be constructed to withstand all operational stresses and to be easily repairable. The invention solves this problem by installing the liner at a certain distance from the inner wall of the pressure vessel shell and by filling this clearance with supporting concrete. Both the concrete and the steel liner must have a lower prestress than the pressure vessel shell. In order to avoid damage to the liner when prestressing the pressure vessel shell, special connecting elements are provided which consist of welded-on fastening elements projecting into recesses in the cast metal segments of the pressure vessel. Their design is described in detail. (TK) [de

  12. Safety vessels for explosive fusion reactor

    International Nuclear Information System (INIS)

    Mineev, V.

    1994-01-01

    The failure of several types of geometrically similar cylindrical and spherical steel and glass fibers vessels filled with water or air was investigated when an explosive charge of TNT was detonated in the center. Vessels had radius 50-1000 mm, thickness of walls 2-20%. The detonation on TNT imitated energy release. The parameter: K = M/mf is a measure of the strength of the vessel where M is the mass of the vessel, and mf is the mass of TNT for which the vessel fails. This demanded 2-4 destroyed and nondestroyed shots. It may be showed that: K=A/σ f where σ f is the fracture stress of the material vessel, and A = const = F(energy TNT, characteristic of elasticity of vessel material). The chief results are the following: (1) A similar increase in the geometrical dimensions of steel vessels by a factor of 10 leads to the increase of parameter K in about 5 times and to decrease of failure deformation in 7 times (scale effect). (2) For glass fibers, scale effect is absent. (3) This problem is solved in terms of theory energetic scale effect. (4) The concept of TNT equivalent explosive makes it possible to use these investigations to evaluate the response of safety vessels for explosive fusion reactor

  13. Radioactive waste processing vessel

    International Nuclear Information System (INIS)

    Hayashi, Masaru; Suzuki, Osamu; Ishizaki, Kanjiro.

    1987-01-01

    Purpose: To obtain a vessel of a reduced weight and with no external leaching of radioactive materials. Constitution: The vessel main body is constituted, for example, with light weight concretes or foamed concretes, particularly, foamed concretes containing fine closed bubbles in the inside. Then, layers having dense texture made of synthetic resin such as polystylene, vinylchloride resin, etc. or metal plate such as stainless plate are integrally disposed to the inner surface of the vessel main body. The cover member also has the same structure. (Sekiya, K.)

  14. Ionizing radiations and blood vessels

    International Nuclear Information System (INIS)

    Vorob'ev, E.I.; Stepanov, R.P.

    1985-01-01

    Data on phenomenology of radiation-induced changes in blood vessels are systematized and authors' experience is generalized. Modern concepts about processes leading to vessel structure injury after irradiation is critically analyzed. Special attention is paid to reparation and compensation of X-ray vessel injury, consideration of which is not yet sufficiently elucidated in literature

  15. Clinical results of single-vessel versus multiple-vessel infrapopliteal intervention

    OpenAIRE

    Darling, Jeremy; McCallum, John C.; Soden, Peter A.; Hon, J.J. (John J.); Guzman, R.J. (Raul J.); Wyers, M.C. (Mark C.); Verhagen, Hence; Schermerhorn, Marc

    2016-01-01

    textabstractObjective The effects of concomitant endovascular interventions on multiple infrapopliteal vessels are not well known, and the short-term and long-term sequelae of such procedures have not been reported. Methods From 2004 to 2014, 673 limbs in 528 patients underwent an infrapopliteal endovascular intervention for tissue loss (77%), rest pain (13%), stenosis of a previously treated vessel (5%), acute limb ischemia (3%), or claudication (2%). Outcomes included wound healing, RAS eve...

  16. Molten material-containing vessel

    International Nuclear Information System (INIS)

    Akagawa, Katsuhiko

    1998-01-01

    The molten material-containing vessel of the present invention comprises a vessel main body having an entrance opened at the upper end, a lid for closing the entrance, an outer tube having an upper end disposed at the lower surface of the lid, extended downwardly and having an closed lower end and an inner tube disposed coaxially with the outer tube. When a molten material is charged from the entrance to the inside of the vessel main body of the molten material-containing vessel and the entrance is closed by the lid, the outer tube and the inner tube are buried in the molten material in the vessel main body, accordingly, a fluid having its temperature elevated by absorption of the heat of the molten material rises along the inner circumferential surface of the outer tube, abuts against the lower surface of the lid and cooled by exchanging heat with the lid and forms a circulating flow. Since the heat in the molten material is continuously absorbed by the fluid, transferred to the lid and released from the lid to the atmospheric air, heat releasing efficiency can be improved compared with conventional cases. (N.H.)

  17. FedWeb Greatest Hits: Presenting the New Test Collection for Federated Web Search

    NARCIS (Netherlands)

    Demeester, Thomas; Trieschnigg, Rudolf Berend; Zhou, Ke; Nguyen, Dong-Phuong; Hiemstra, Djoerd

    This paper presents 'FedWeb Greatest Hits', a large new test collection for research in web information retrieval. As a combination and extension of the datasets used in the TREC Federated Web Search Track, this collection opens up new research possibilities on federated web search challenges, as

  18. Americium behaviour in plastic vessels.

    Science.gov (United States)

    Legarda, F; Herranz, M; Idoeta, R; Abelairas, A

    2010-01-01

    The adsorption of (241)Am dissolved in water in different plastic storage vessels was determined. Three different plastics were investigated with natural and distilled waters and the retention of (241)Am by these plastics was studied. The same was done by varying vessel agitation time, vessel agitation speed, surface/volume ratio of water in the vessels and water pH. Adsorptions were measured to be between 0% and 70%. The adsorption of (241)Am is minimized with no water agitation, with PET or PVC plastics, and by water acidification. Copyright 2009 Elsevier Ltd. All rights reserved.

  19. Vessel Sampling and Blood Flow Velocity Distribution With Vessel Diameter for Characterizing the Human Bulbar Conjunctival Microvasculature.

    Science.gov (United States)

    Wang, Liang; Yuan, Jin; Jiang, Hong; Yan, Wentao; Cintrón-Colón, Hector R; Perez, Victor L; DeBuc, Delia C; Feuer, William J; Wang, Jianhua

    2016-03-01

    This study determined (1) how many vessels (i.e., the vessel sampling) are needed to reliably characterize the bulbar conjunctival microvasculature and (2) if characteristic information can be obtained from the distribution histogram of the blood flow velocity and vessel diameter. Functional slitlamp biomicroscope was used to image hundreds of venules per subject. The bulbar conjunctiva in five healthy human subjects was imaged on six different locations in the temporal bulbar conjunctiva. The histograms of the diameter and velocity were plotted to examine whether the distribution was normal. Standard errors were calculated from the standard deviation and vessel sample size. The ratio of the standard error of the mean over the population mean was used to determine the sample size cutoff. The velocity was plotted as a function of the vessel diameter to display the distribution of the diameter and velocity. The results showed that the sampling size was approximately 15 vessels, which generated a standard error equivalent to 15% of the population mean from the total vessel population. The distributions of the diameter and velocity were not only unimodal, but also somewhat positively skewed and not normal. The blood flow velocity was related to the vessel diameter (r=0.23, Psampling size of the vessels and the distribution histogram of the blood flow velocity and vessel diameter, which may lead to a better understanding of the human microvascular system of the bulbar conjunctiva.

  20. Dynamic simulation of the NET In-Vessel Handling Unit

    International Nuclear Information System (INIS)

    Reim, J.

    1991-01-01

    During the conceptual design phase of the Next European Torus (NET) a large remote maintenance transporter system, the In-Vessel Handling Unit (IVHU), is being developed. It consists of an articulated boom with four rotational joints, which is mounted on a carrier outside the vessel. This boom will be able to carry master-slave manipulators or special work units. The engineering design is supported by dynamic computations. Main topics of the dynamic simulation are the evaluation of IVHU performance, selection and optimisation of the actuator design and of the control algorithms. This simulation task requires full three-dimensional modelling regarding structural elasticity and non-linear actuator dynamics. The Multibody dynamics of the transporter system are modelled with a commerical analysis package. Elastic links and a precise dynamic actuator model are introduced by applied forces, spring elements and differential equations. The actuator model comprises electric motors, gears and linear control algorithms. Non-linear effects which have an influence on control stability and accuracy are taken into account. Most important effects are backlash and static friction. The simulations concentrate on test and optimisation of the control layout and performance studies for critical remote handling tasks. Simulations for control layout and critical remote maintenance tasks correspond to the design objectives of the transporter system. (orig.)

  1. Radiation embrittlement of PWR vessel supports

    International Nuclear Information System (INIS)

    Cheverton, R.D.; Robinson, G.C.; Pennell, W.E.; Nanstad, R.K.

    1989-01-01

    Several studies pertaining to radiation damage of PWR vessel supports were conducted between 1978 and 1987. During this period, apparently there was no reason to believe that low-temperature (<100 degree C) MTR embrittlement data were not appropriate for evaluating embrittlement of PWR vessel supports. However, late in 1986, data from the High Flux Isotope Reactor (HFIR) vessel surveillance program indicated that the embrittlement rates of the several HFIR vessel materials (A212-B, A350-LF3, A105-II) were substantially greater than anticipated on the basis of MTR data. Further evaluation of the HFIR data suggested that a fluence-rate effect was responsible for the apparent discrepancy, and shortly thereafter it became apparent that this rate effect was applicable to the evaluation of LWR vessel supports. As a result, the Nuclear Regulatory Commission (NRC) requested that the Oak Ridge National Laboratory (ORNL) evaluate the impact of the apparent embrittlement rate effect on the integrity of light-water-reactor (LWR) vessel supports. The purpose of the study was to provide an indication of whether the integrity of reactor vessel supports is likely to be challenged by radiation-induced embrittlement. The scope of the evaluation included correlation of the HFIR data for application to the evaluation of LWR vessel supports; a survey and cursory evaluation of all US LWR vessel support designs, selection of two plants for specific-plant evaluation, and a specific-plant evaluation of both plants to determine critical flaw sizes for their vessel supports. 19 refs., 8 figs., 2 tabs

  2. Prestressed cast iron pressure vessels as burst-proof pressure vessels for innovative nuclear applications

    International Nuclear Information System (INIS)

    Froehling, W.; Boettcher, A.; Bounin, D.; Steinwarz, W.; Geiss, M.; Trauth, M.

    2000-01-01

    The amendment to the German Atomic Energy Act from July 28, 1994 requires that events 'whose occurrence is practically excluded by the measures against damages', i.e. events of the category residual risk, must not necessitate far reaching protective measures outside the plant. For a conventional reactor pressure vessel, the residual risk consists in the very small probability of a catastrophic failure (formation of a large fracture opening, bursting of the vessel). With a prestressed cast iron vessel (PCIV), the formation of a large fracture opening or bursting of the vessel, respectively, is impossible due to its design properties. Against this background the possibility of the use of this type of pressure vessel for lightwater reactors has been studied in the frame of a 'Working Group for Innovative Nuclear Technology', founded by different research institutes and industrial companies. Furthermore, it has been studied whether the use of the PCIV support the realization of a corecatcher system. The results are presented in this report. Already many years earlier, Siempelkamp has performed industrial development and Forschungszentrum Juelich related experimental and theoretical safety research for the PCIV as an innovative, bust-proof pressure vessel concept. This development of the PCIV as well as its safety properties are also presented in a conclusive manner. (orig.) [de

  3. 46 CFR 4.03-40 - Public vessels.

    Science.gov (United States)

    2010-10-01

    ... INVESTIGATIONS Definitions § 4.03-40 Public vessels. Public vessel means a vessel that— (a) Is owned, or demise... Department (except a vessel operated by the Coast Guard or Saint Lawrence Seaway Development Corporation...

  4. Extraction of liver volumetry based on blood vessel from the portal phase CT dataset

    Science.gov (United States)

    Maklad, Ahmed S.; Matsuhiro, Mikio; Suzuki, Hidenobu; Kawata, Yoshiki; Niki, Noboru; Utsunomiya, Tohru; Shimada, Mitsuo

    2012-02-01

    At liver surgery planning stage, the liver volumetry would be essential for surgeons. Main problem at liver extraction is the wide variability of livers in shapes and sizes. Since, hepatic blood vessels structure varies from a person to another and covers liver region, the present method uses that information for extraction of liver in two stages. The first stage is to extract abdominal blood vessels in the form of hepatic and nonhepatic blood vessels. At the second stage, extracted vessels are used to control extraction of liver region automatically. Contrast enhanced CT datasets at only the portal phase of 50 cases is used. Those data include 30 abnormal livers. A reference for all cases is done through a comparison of two experts labeling results and correction of their inter-reader variability. Results of the proposed method agree with the reference at an average rate of 97.8%. Through application of different metrics mentioned at MICCAI workshop for liver segmentation, it is found that: volume overlap error is 4.4%, volume difference is 0.3%, average symmetric distance is 0.7 mm, Root mean square symmetric distance is 0.8 mm, and maximum distance is 15.8 mm. These results represent the average of overall data and show an improved accuracy compared to current liver segmentation methods. It seems to be a promising method for extraction of liver volumetry of various shapes and sizes.

  5. DOMPAC dosimetry experiment. Neutronic simulation of the thickness of a PWR pressure vessel. Irradiation damages

    International Nuclear Information System (INIS)

    Alberman, A.; Faure, M.; Thierry, M.; Hoclet, O.; Le Dieu de Ville, A.; Nimal, J.C.; Soulat, P.

    1979-01-01

    For suitable extrapolation of irradiated PWR ferritic steel results, proper irradiation of the pressure vessel has been 'simulated' in test reactor. For this purpose, a huge steel block (20 cm in depth) was loaded with Saclay's graphite (GAMIN) and tungsten damage detectors. Core-block water gap was optimized through spectrum indexes method, by ANISN and SABINE codes so that spectrum in 1/4 thickness matches with ANISN computations for PWR Fessenheim 1. A good experimental agreement is found with calculated dpa damage gradient. 3D Monte Carlo computation (TRIPOLI), was performed on the DOMPAC device, and spectrum indexes evolution was found consistent with experimental results. Surveillance rigs behind a 'thermal shield' were also simulated, including damage and activation monitors. Dosimetry results give an order of magnitude of accuracies involved in projecting steel sample embrittlement to the pressure vessel [fr

  6. The greatest challenges reported by long-term colorectal cancer survivors with stomas.

    Science.gov (United States)

    McMullen, Carmit K; Hornbrook, Mark C; Grant, Marcia; Baldwin, Carol M; Wendel, Christopher S; Mohler, M Jane; Altschuler, Andrea; Ramirez, Michelle; Krouse, Robert S

    2008-04-01

    This paper presents a qualitative analysis of the greatest challenges reported by long-term colorectal cancer survivors with ostomies. Surveys that included an open-ended question about challenges of living with an ostomy were administered at three Kaiser Permanente regions: Northern California, Northwest, and Hawaii. The study was coordinated at the Southern Arizona Veterans Affairs Health Care System in Tucson. The City of Hope Quality of Life Model for Ostomy Patients provided a framework for the study's design, measures, data collection, and data analysis. The study's findings may be generalized broadly to community settings across the United States. Results replicate those of previous research among veterans, California members of the United Ostomy Association, Koreans with ostomies, and colorectal cancer survivors with ostomies residing in the United Kingdom. The greatest challenges reported by 178 colorectal cancer survivors with ostomies confirmed the Institute of Medicine's findings that survivorship is a distinct, chronic phase of cancer care and that cancer's effects are broad and pervasive. The challenges reported by study participants should inform the design, testing and integration of targeted education, early interventions, and ongoing support services for colorectal cancer patients with ostomies.

  7. Prosopomorphic vessels from Moesia Superior

    Directory of Open Access Journals (Sweden)

    Nikolić Snežana

    2008-01-01

    Full Text Available The prosopomorphic vessels from Moesia Superior had the form of beakers varying in outline but similar in size. They were wheel-thrown, mould-made or manufactured by using a combination of wheel-throwing and mould-made appliqués. Given that face vessels are considerably scarcer than other kinds of pottery, more than fifty finds from Moesia Superior make an enviable collection. In this and other provinces face vessels have been recovered from military camps, civilian settlements and necropolises, which suggests that they served more than one purpose. It is generally accepted that the faces-masks gave a protective role to the vessels, be it to protect the deceased or the family, their house and possessions. More than forty of all known finds from Moesia Superior come from Viminacium, a half of that number from necropolises. Although tangible evidence is lacking, there must have been several local workshops producing face vessels. The number and technological characteristics of the discovered vessels suggest that one of the workshops is likely to have been at Viminacium, an important pottery-making centre in the second and third centuries.

  8. Targeting Therapy Resistant Tumor Vessels

    Science.gov (United States)

    2008-08-01

    Morris LS. Hysterectomy vs. resectoscopic endometrial ablation for the control of abnormal uterine bleeding . A cost-comparative study. J Reprod Med 1994;39...after the antibody treatment contain a pericyte coat, vessel architecture is normal, the diameter of the vessels is smaller (dilated, abnormal vessels...involvement of proteases from inflammatory mast cells and functionally abnormal (Carmeliet and Jain, 2000; Pasqualini (Coussens et al., 1999) and other bone

  9. Automated Registration of Multimodal Optic Disc Images: Clinical Assessment of Alignment Accuracy.

    Science.gov (United States)

    Ng, Wai Siene; Legg, Phil; Avadhanam, Venkat; Aye, Kyaw; Evans, Steffan H P; North, Rachel V; Marshall, Andrew D; Rosin, Paul; Morgan, James E

    2016-04-01

    To determine the accuracy of automated alignment algorithms for the registration of optic disc images obtained by 2 different modalities: fundus photography and scanning laser tomography. Images obtained with the Heidelberg Retina Tomograph II and paired photographic optic disc images of 135 eyes were analyzed. Three state-of-the-art automated registration techniques Regional Mutual Information, rigid Feature Neighbourhood Mutual Information (FNMI), and nonrigid FNMI (NRFNMI) were used to align these image pairs. Alignment of each composite picture was assessed on a 5-point grading scale: "Fail" (no alignment of vessels with no vessel contact), "Weak" (vessels have slight contact), "Good" (vessels with 50% contact), and "Excellent" (complete alignment). Custom software generated an image mosaic in which the modalities were interleaved as a series of alternate 5×5-pixel blocks. These were graded independently by 3 clinically experienced observers. A total of 810 image pairs were assessed. All 3 registration techniques achieved a score of "Good" or better in >95% of the image sets. NRFNMI had the highest percentage of "Excellent" (mean: 99.6%; range, 95.2% to 99.6%), followed by Regional Mutual Information (mean: 81.6%; range, 86.3% to 78.5%) and FNMI (mean: 73.1%; range, 85.2% to 54.4%). Automated registration of optic disc images by different modalities is a feasible option for clinical application. All 3 methods provided useful levels of alignment, but the NRFNMI technique consistently outperformed the others and is recommended as a practical approach to the automated registration of multimodal disc images.

  10. Pressurized wet digestion in open vessels (T11)

    International Nuclear Information System (INIS)

    Kettisch, P.; Maichin, P.; Zischka, M.; Knapp, G.

    2002-01-01

    Full text: Pressurized wet digestion in closed vessels, microwave assisted or with conventional conductive heating, is the most important sample preparation technique for digestion or leaching procedures in element analysis. In comparison to open vessel digestion closed vessel digestion methods have many advantages, but there is one disadvantage - complex and expensive vessel designs. A new technique - pressurized wet digestion in open vessels - combine the advantages of closed vessel sample digestion with the application of simple and cheap open vessels made of quartz or PFA. The vessels are placed in a high pressure Asher HPA, which is adapted with a Teflon liner and filled partly with water. The analytical results with 30 ml quartz vessels, 22 ml PFA vessels and 1.5 ml PIA auto sampler cups will be shown. In principle every dimensions of vessels can be used. The vessels are loaded with sample material (max. 1.5 g with quartz vessels, max. 0.5 g with PFA vessels and 50 mg with auto sampler cups) and digestion reagent. Afterwards the vessels are simply covered with PTFE stoppers and not sealed. The vessels are transferred into a special adapted HPA and digested at temperatures up to 270 o C. The digestion time is 90 min. and cooling down to room temperature 30 min. The analytical results of CRM's are within the certified values and no cross contamination and losses of volatile elements could be observed. (author)

  11. Evaluation of approaches for estimating the accuracy of genomic prediction in plant breeding.

    Science.gov (United States)

    Ould Estaghvirou, Sidi Boubacar; Ogutu, Joseph O; Schulz-Streeck, Torben; Knaak, Carsten; Ouzunova, Milena; Gordillo, Andres; Piepho, Hans-Peter

    2013-12-06

    In genomic prediction, an important measure of accuracy is the correlation between the predicted and the true breeding values. Direct computation of this quantity for real datasets is not possible, because the true breeding value is unknown. Instead, the correlation between the predicted breeding values and the observed phenotypic values, called predictive ability, is often computed. In order to indirectly estimate predictive accuracy, this latter correlation is usually divided by an estimate of the square root of heritability. In this study we use simulation to evaluate estimates of predictive accuracy for seven methods, four (1 to 4) of which use an estimate of heritability to divide predictive ability computed by cross-validation. Between them the seven methods cover balanced and unbalanced datasets as well as correlated and uncorrelated genotypes. We propose one new indirect method (4) and two direct methods (5 and 6) for estimating predictive accuracy and compare their performances and those of four other existing approaches (three indirect (1 to 3) and one direct (7)) with simulated true predictive accuracy as the benchmark and with each other. The size of the estimated genetic variance and hence heritability exerted the strongest influence on the variation in the estimated predictive accuracy. Increasing the number of genotypes considerably increases the time required to compute predictive accuracy by all the seven methods, most notably for the five methods that require cross-validation (Methods 1, 2, 3, 4 and 6). A new method that we propose (Method 5) and an existing method (Method 7) used in animal breeding programs were the fastest and gave the least biased, most precise and stable estimates of predictive accuracy. Of the methods that use cross-validation Methods 4 and 6 were often the best. The estimated genetic variance and the number of genotypes had the greatest influence on predictive accuracy. Methods 5 and 7 were the fastest and produced the least

  12. Seals for sealing a pressure vessel such as a nuclear reactor vessel or the like

    International Nuclear Information System (INIS)

    Bruns, H.J.; Huelsermann, K.H.

    1975-01-01

    A description is given of seals for sealing a pressure vessel such as a nuclear reactor vessel, steam boiler vessel, or any other vessel which is desirably sealed against pressure of the type including a housing and a housing closure that present opposed vertical sealing surfaces which define the sides of a channel. The seals of the present invention comprise at least one sealing member disposed in the channel, having at least one stop face, a base portion and two shank portions extending from the base portion to form a groove-like recess. The shank portions are provided with sealing surfaces arranged to mate with the opposed vertical pressure vessel sealing surfaces. A shank-spreading wedge element also disposed in the channel has at least one stop face and is engaged in the groove-like recess with the sealing member and wedge element stop face adjacent to each other

  13. Proposal of Ex-Vessel dosimetry for pressure vessel Atucha II

    International Nuclear Information System (INIS)

    Chiaraviglio, N.; Bazzana, S.

    2013-01-01

    Nuclear reactor dosimetry has the purpose of guarantee that changes in material mechanical properties of critical materials do not compromise the reactor safety. In PWR in which the top of the reactor vessel is open once a year, is possible to use Charpy specimens to measure the change in mechanical properties. Atucha II nuclear power plant is a reactor with on-line refueling so there is no access to the inside of the pressure vessel. Because of this, ex-vessel dosimetry must be performed and mechanical properties changes must be inferred from radiation damage estimations. This damage can be calculated using displacement per atom cross sections and a transport code such as MCNP. To increase results reliability it is proposed to make a neutron spectrum unfolding using activation dosimeters irradiated during one operation cycle of the power plant. In this work we present a dosimetry proposal for such end, made in base of unfolding procedures and experimental background. (author) [es

  14. Hypoattenuation on CTA images with large vessel occlusion: timing affects conspicuity

    Energy Technology Data Exchange (ETDEWEB)

    Dave, Prasham [University of Ottawa, MD Program, Faculty of Medicine, Ottawa, ON (Canada); Lum, Cheemun; Thornhill, Rebecca; Chakraborty, Santanu [University of Ottawa, Department of Radiology, Ottawa, ON (Canada); Ottawa Hospital Research Institute, Ottawa, ON (Canada); Dowlatshahi, Dar [Ottawa Hospital Research Institute, Ottawa, ON (Canada); University of Ottawa, Division of Neurology, Department of Medicine, Ottawa, ON (Canada)

    2017-05-15

    Parenchymal hypoattenuation distal to occlusions on CTA source images (CTASI) is perceived because of the differences in tissue contrast compared to normally perfused tissue. This difference in conspicuity can be measured objectively. We evaluated the effect of contrast timing on the conspicuity of ischemic areas. We collected consecutive patients, retrospectively, between 2012 and 2014 with large vessel occlusions that had dynamic multiphase CT angiography (CTA) and CT perfusion (CTP). We identified areas of low cerebral blood volume on CTP maps and drew the region of interest (ROI) on the corresponding CTASI. A second ROI was placed in an area of normally perfused tissue. We evaluated conspicuity by comparing the absolute and relative change in attenuation between ischemic and normally perfused tissue over seven time points. The median absolute and relative conspicuity was greatest at the peak arterial (8.6 HU (IQR 5.1-13.9); 1.15 (1.09-1.26)), notch (9.4 HU (5.8-14.9); 1.17 (1.10-1.27)), and peak venous phases (7.0 HU (3.1-12.7); 1.13 (1.05-1.23)) compared to other portions of the time-attenuation curve (TAC). There was a significant effect of phase on the TAC for the conspicuity of ischemic vs normally perfused areas (P < 0.00001). The conspicuity of ischemic areas distal to a large artery occlusion in acute stroke is dependent on the phase of contrast arrival with dynamic CTASI and is objectively greatest in the mid-phase of the TAC. (orig.)

  15. High Performance Marine Vessels

    CERN Document Server

    Yun, Liang

    2012-01-01

    High Performance Marine Vessels (HPMVs) range from the Fast Ferries to the latest high speed Navy Craft, including competition power boats and hydroplanes, hydrofoils, hovercraft, catamarans and other multi-hull craft. High Performance Marine Vessels covers the main concepts of HPMVs and discusses historical background, design features, services that have been successful and not so successful, and some sample data of the range of HPMVs to date. Included is a comparison of all HPMVs craft and the differences between them and descriptions of performance (hydrodynamics and aerodynamics). Readers will find a comprehensive overview of the design, development and building of HPMVs. In summary, this book: Focuses on technology at the aero-marine interface Covers the full range of high performance marine vessel concepts Explains the historical development of various HPMVs Discusses ferries, racing and pleasure craft, as well as utility and military missions High Performance Marine Vessels is an ideal book for student...

  16. Reactor-vessel-sectioning demonstration

    International Nuclear Information System (INIS)

    Lundgren, R.A.

    1981-07-01

    A successful technical demonstration of simulated reactor vessel sectioning was completed using the combined techniques of air arc gouging and flame cutting. A 4-ft x 3-ft x 9-in. thick sample was fabricated of A36 carbon steel to simulate a reactor vessel wall. A 1/4-in layer of stainless steel (SS) was tungsten inert gas (TIG)-welded to the carbon steel. Several techniques were considered to section the simulated reactor vessel: an air arc gouger was chosen to penetrate the stainless steel, and flame cutting was selected to sever the carbon steel. After the simulated vessel was successfully cut from the SS side, another cut was made, starting from the carbon steel side. This cut was also successful. Cutting from the carbon steel side has the advantages of cost reduction since the air arc gouging step is eliminated and contamination controlled because the molten metal is blown inward

  17. The vessel fluence; Fluence cuve

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2001-07-01

    This book presents the proceedings of the technical meeting on the reactors vessels fluence. They are grouped in eight sessions: the industrial context and the stakes of the vessels control; the organization and the methodology for the fluence computation; the concerned physical properties; the reference computation methods; the fluence monitoring in an industrial context; vessels monitoring under irradiation; others methods in the world; the research and development programs. (A.L.B.)

  18. Relative Vessel Motion Tracking using Sensor Fusion, Aruco Markers, and MRU Sensors

    Directory of Open Access Journals (Sweden)

    Sondre Sanden Tordal

    2017-04-01

    Full Text Available This paper presents a novel approach for estimating the relative motion between two moving offshore vessels. The method is based on a sensor fusion algorithm including a vision system and two motion reference units (MRUs. The vision system makes use of the open-source computer vision library OpenCV and a cube with Aruco markers placed onto each of the cube sides. The Extended Quaternion Kalman Filter (EQKF is used for bad pose rejection for the vision system. The presented sensor fusion algorithm is based on the Indirect Feedforward Kalman Filter for error estimation. The system is self-calibrating in the sense that the Aruco cube can be placed in an arbitrary location on the secondary vessel. Experimental 6-DOF results demonstrate the accuracy and efficiency of the proposed sensor fusion method compared with the internal joint sensors of two Stewart platforms and the industrial robot. The standard deviation error was found to be 31mm or better when the Arcuo cube was placed at three different locations.

  19. Pulmonary vessel segmentation utilizing curved planar reformation and optimal path finding (CROP) in computed tomographic pulmonary angiography (CTPA) for CAD applications

    Science.gov (United States)

    Zhou, Chuan; Chan, Heang-Ping; Kuriakose, Jean W.; Chughtai, Aamer; Wei, Jun; Hadjiiski, Lubomir M.; Guo, Yanhui; Patel, Smita; Kazerooni, Ella A.

    2012-03-01

    Vessel segmentation is a fundamental step in an automated pulmonary embolism (PE) detection system. The purpose of this study is to improve the segmentation scheme for pulmonary vessels affected by PE and other lung diseases. We have developed a multiscale hierarchical vessel enhancement and segmentation (MHES) method for pulmonary vessel tree extraction based on the analysis of eigenvalues of Hessian matrices. However, it is difficult to segment the pulmonary vessels accurately under suboptimal conditions, such as vessels occluded by PEs, surrounded by lymphoid tissues or lung diseases, and crossing with other vessels. In this study, we developed a new vessel refinement method utilizing curved planar reformation (CPR) technique combined with optimal path finding method (MHES-CROP). The MHES segmented vessels straightened in the CPR volume was refined using adaptive gray level thresholding where the local threshold was obtained from least-square estimation of a spline curve fitted to the gray levels of the vessel along the straightened volume. An optimal path finding method based on Dijkstra's algorithm was finally used to trace the correct path for the vessel of interest. Two and eight CTPA scans were randomly selected as training and test data sets, respectively. Forty volumes of interest (VOIs) containing "representative" vessels were manually segmented by a radiologist experienced in CTPA interpretation and used as reference standard. The results show that, for the 32 test VOIs, the average percentage volume error relative to the reference standard was improved from 32.9+/-10.2% using the MHES method to 9.9+/-7.9% using the MHES-CROP method. The accuracy of vessel segmentation was improved significantly (pvolume between the automated segmentation and the reference standard was improved from 0.919 to 0.988. Quantitative comparison of the MHES method and the MHES-CROP method with the reference standard was also evaluated by the Bland-Altman plot. This preliminary

  20. Expanded Fermilab pressure vessel directory program

    Energy Technology Data Exchange (ETDEWEB)

    Tanner, A.

    1983-01-01

    Several procedures have been written to manage the information pertaining to the vacuum tanks and pressure vessels for which the laboratory is responsible. These procedures have been named TANK1 for the vessels belonging to the Accelerator Division, TANK2 and TANK3 for the vessels belonging to the Research Division and to Technical Support respectively, and TANK4 for the vessels belonging to the Business Division. The operating procedures are otherwise identical in every respect.

  1. Expanded Fermilab pressure vessel directory program

    International Nuclear Information System (INIS)

    Tanner, A.

    1983-01-01

    Several procedures have been written to manage the information pertaining to the vacuum tanks and pressure vessels for which the laboratory is responsible. These procedures have been named TANK1 for the vessels belonging to the Accelerator Division, TANK2 and TANK3 for the vessels belonging to the Research Division and to Technical Support respectively, and TANK4 for the vessels belonging to the Business Division. The operating procedures are otherwise identical in every respect

  2. Effect of the in- and ex-vessel dual cooling on the retention of an internally heated melt pool in a hemispherical vessel

    Energy Technology Data Exchange (ETDEWEB)

    Ahn, K.I.; Kim, B.S.; Kim, D.H. [Korea Atomic Energy Research Inst., Thermal Hydraulic Safety Research, Taejon (Korea, Republic of)

    2001-07-01

    A concept of in-vessel melt retention (IVMR) by in-vessel reflooding and/or reactor cavity flooding has been considered as one of severe accident management strategies and intensive researches to be performed worldwide. This paper provides some results of analytical investigations on the effect of both in- / ex-vessel cooling on the retention of an internally heated molten pool confined in a hemispherical vessel and the related thermal behavior of the vessel wall. For the present analysis, a scale-down reactor vessel for the KSNP reactor design of 1000 MWe (a large dry PWR) is utilized for a reactor vessel. Aluminum oxide melt simulant is also utilized for a real corium pool. An internal power density in the molten pool is determined by a simple scaling analysis that equates the heat flux on the the scale-down vessel wall to that estimated from KSNP. Well-known temperature-dependent boiling heat transfer curves are applied to the in- and ex-vessel cooling boundaries and radiative heat transfer has been only considered in the case of dry in-vessel. MELTPOOL, which is a computational fluid dynamics (CFD) code developed at KAERI, is applied to obtain the time-varying heat flux distribution from a molten pool and the vessel wall temperature distributions with angular positions along the vessel wall. In order to gain further insights on the effectiveness of in- and ex-vessel dual cooling on the in-vessel corium retention, four different boundary conditions has been considered: no water inside the vessel without ex-vessel cooling, water inside the vessel without ex-vessel cooling, no water inside the vessel with ex-vessel cooling, and water inside the vessel with ex-vessel cooling. (authors)

  3. Effect of the in- and ex-vessel dual cooling on the retention of an internally heated melt pool in a hemispherical vessel

    International Nuclear Information System (INIS)

    Ahn, K.I.; Kim, B.S.; Kim, D.H.

    2001-01-01

    A concept of in-vessel melt retention (IVMR) by in-vessel reflooding and/or reactor cavity flooding has been considered as one of severe accident management strategies and intensive researches to be performed worldwide. This paper provides some results of analytical investigations on the effect of both in- / ex-vessel cooling on the retention of an internally heated molten pool confined in a hemispherical vessel and the related thermal behavior of the vessel wall. For the present analysis, a scale-down reactor vessel for the KSNP reactor design of 1000 MWe (a large dry PWR) is utilized for a reactor vessel. Aluminum oxide melt simulant is also utilized for a real corium pool. An internal power density in the molten pool is determined by a simple scaling analysis that equates the heat flux on the the scale-down vessel wall to that estimated from KSNP. Well-known temperature-dependent boiling heat transfer curves are applied to the in- and ex-vessel cooling boundaries and radiative heat transfer has been only considered in the case of dry in-vessel. MELTPOOL, which is a computational fluid dynamics (CFD) code developed at KAERI, is applied to obtain the time-varying heat flux distribution from a molten pool and the vessel wall temperature distributions with angular positions along the vessel wall. In order to gain further insights on the effectiveness of in- and ex-vessel dual cooling on the in-vessel corium retention, four different boundary conditions has been considered: no water inside the vessel without ex-vessel cooling, water inside the vessel without ex-vessel cooling, no water inside the vessel with ex-vessel cooling, and water inside the vessel with ex-vessel cooling. (authors)

  4. Vacuum vessel for thermonuclear device

    International Nuclear Information System (INIS)

    Kikuchi, Mitsuru; Kurita, Gen-ichi; Onozuka, Masaki; Suzuki, Masaru.

    1997-01-01

    Heat of inner walls of a vacuum vessel that receive radiation heat from plasmas by way of first walls is removed by a cooling medium flowing in channels for cooling the inner walls. Nuclear heat generation of constitutional materials of the vacuum vessel caused by fast neutrons and γ rays is removed by a cooling medium flowing in cooling channels disposed in the vacuum vessel. Since the heat from plasmas and the nuclear heat generation are removed separately, the amount of the cooling medium flowing in the channels for cooling inner walls is increased for cooling a great amount of heat from plasmas while the amount of the cooling medium flowing in the channels for cooling the inside of the vacuum vessel is reduced for cooling the small amount of nuclear heat generation. Since the amount of the cooling medium can thus be optimized, the capacity of the facilities for circulating the cooling medium can be reduced. In addition, since the channels for cooling the inner walls and the channels of cooling medium formed in the vacuum vessel are disposed to the inner walls of the vacuum vessel on the side opposite to plasmas, integrity of the channels relative to leakage of the cooling medium can be ensured. (N.H.)

  5. Vacuum vessel for thermonuclear device

    Energy Technology Data Exchange (ETDEWEB)

    Kikuchi, Mitsuru; Kurita, Gen-ichi [Japan Atomic Energy Research Inst., Tokyo (Japan); Onozuka, Masaki; Suzuki, Masaru

    1997-07-31

    Heat of inner walls of a vacuum vessel that receive radiation heat from plasmas by way of first walls is removed by a cooling medium flowing in channels for cooling the inner walls. Nuclear heat generation of constitutional materials of the vacuum vessel caused by fast neutrons and {gamma} rays is removed by a cooling medium flowing in cooling channels disposed in the vacuum vessel. Since the heat from plasmas and the nuclear heat generation are removed separately, the amount of the cooling medium flowing in the channels for cooling inner walls is increased for cooling a great amount of heat from plasmas while the amount of the cooling medium flowing in the channels for cooling the inside of the vacuum vessel is reduced for cooling the small amount of nuclear heat generation. Since the amount of the cooling medium can thus be optimized, the capacity of the facilities for circulating the cooling medium can be reduced. In addition, since the channels for cooling the inner walls and the channels of cooling medium formed in the vacuum vessel are disposed to the inner walls of the vacuum vessel on the side opposite to plasmas, integrity of the channels relative to leakage of the cooling medium can be ensured. (N.H.)

  6. Tempest in a vessel

    International Nuclear Information System (INIS)

    Barre, Bertrand

    2015-01-01

    As the ASN made some statements about anomalies of carbon content in the EPR vessel bottom and top, the author recalls and comments some technical issues to better understand the information published on this topic. He notably addresses the role of the vessel, briefly indicates its operating conditions, shape and structure, and mechanical components for the top, its material and mechanical properties, and test samples used to assess mechanical properties. He also comments the phenomenon of radio-induced embrittlement, the vessel manufacturing process, and evokes the applicable regulations. He quotes and comments statements made by the ASN and Areva which evoke further assessments of the concerned components

  7. The prospect of modern thermomechanics in structural integrity calculations of large-scale pressure vessels

    Science.gov (United States)

    Fekete, Tamás

    2018-05-01

    Structural integrity calculations play a crucial role in designing large-scale pressure vessels. Used in the electric power generation industry, these kinds of vessels undergo extensive safety analyses and certification procedures before deemed feasible for future long-term operation. The calculations are nowadays directed and supported by international standards and guides based on state-of-the-art results of applied research and technical development. However, their ability to predict a vessel's behavior under accidental circumstances after long-term operation is largely limited by the strong dependence of the analysis methodology on empirical models that are correlated to the behavior of structural materials and their changes during material aging. Recently a new scientific engineering paradigm, structural integrity has been developing that is essentially a synergistic collaboration between a number of scientific and engineering disciplines, modeling, experiments and numerics. Although the application of the structural integrity paradigm highly contributed to improving the accuracy of safety evaluations of large-scale pressure vessels, the predictive power of the analysis methodology has not yet improved significantly. This is due to the fact that already existing structural integrity calculation methodologies are based on the widespread and commonly accepted 'traditional' engineering thermal stress approach, which is essentially based on the weakly coupled model of thermomechanics and fracture mechanics. Recently, a research has been initiated in MTA EK with the aim to review and evaluate current methodologies and models applied in structural integrity calculations, including their scope of validity. The research intends to come to a better understanding of the physical problems that are inherently present in the pool of structural integrity problems of reactor pressure vessels, and to ultimately find a theoretical framework that could serve as a well

  8. Speech production accuracy and variability in young cochlear implant recipients: comparisons with typically developing age-peers.

    Science.gov (United States)

    Ertmer, David J; Goffman, Lisa

    2011-02-01

    The speech production accuracy and variability scores of 6 young cochlear implant (CI) recipients with 2 years of device experience were compared with those of typically developing (TD) age-peers. Words from the First Words Speech Test (FWST; Ertmer, 1999) were imitated 3 times to assess the accuracy and variability of initial consonants, vowels, and words. The initial consonants in the 4 sets of the FWST followed a typical order of development. The TD group produced targets with high accuracy and low variability. Their scores across FWST sets reflected the expected order of development. The CI group produced most targets less accurately and with more variability than the TD children. Relatively high accuracy for the consonants of Sets 1 and 2 indicated that these phonemes were acquired early and in a typical developmental order. A trend toward greater accuracy for Set 4 as compared with Set 3 suggested that later-emerging consonants were not acquired in the expected order. Variability was greatest for later-emerging initial consonants and whole words. Although considerable speech production proficiency was evident, age-level performance was not attained after 2 years of CI experience. Factors that might influence the order of consonant acquisition are discussed.

  9. Nuclear reactor construction with bottom supported reactor vessel

    International Nuclear Information System (INIS)

    Sharbaugh, J.E.

    1987-01-01

    This patent describes an improved liquid metal nuclear reactor construction comprising: (a) a nuclear reactor core having a bottom platform support structure; (b) a reactor vessel for holding a large pool of low pressure liquid metal coolant and housing the core; (c) a containment structure surrounding the reactor vessel and having a sidewall spaced outwardly from the reactor vessel side wall and having a base mat spaced below the reactor vessel bottom end wall; (d) a central small diameter post anchored to the containment structure base mat and extending upwardly to the reactor vessel to axially fix the bottom end wall of the reactor vessel and provide a center column support for the lower end of the reactor core; (e) annular support structure disposed in the reactor vessel on the bottom end wall and extending about the lower end of the core; (f) structural support means disposed between the containment structure base mat and bottom end of the reactor vessel wall and cooperating for supporting the reactor vessel at its bottom end wall on the containment structure base mat to allow the reactor vessel to expand radially but substantially prevent any lateral motions that might be imposed by the occurrence of a seismic event; (g) a bed of insulating material disposed between the containment structure base mat and the bottom end wall of the reactor vessel and uniformly supporting the reactor vessel at its bottom end wall; freely expand radially from the central post as it heats up while providing continuous support thereof; (h) a deck supported upon the wall of the containment vessel above the top open end of the reactor vessel; and (i) extendible and retractable coupling means extending between the deck and the top open end of the reactor vessel and flexibly and sealably interconnecting the reactor vessel at its top end to the deck

  10. Masses of galaxies and the greatest redshifts of quasars

    Energy Technology Data Exchange (ETDEWEB)

    Hills, J G [Illinois Univ., Urbana (USA)

    1977-04-01

    The outer parts of a typical galaxy follows an R/sup -2/ density distribution which results in the collapse time of its protogalaxy being proportional to its mass. Since quasars probably occur in the nuclei of galaxies which can only form after the collapse of their parent galaxies, their greatest observed redshift, Zsub(max), is largely determined by the mass, Msub(t), of a typical protogalaxy. The observed Zsub(max) of quasars indicates that Msub(t) = 1 x 10/sup 12/ solar masses. This mass is consistent with the masses of galaxies found in recent dynamical studies. It indicates that most of the mass in a typical galaxy is in the halo lying beyond the familiar optically-bright core, but the mass of a standard galaxy is still only 0.3 of that required for galaxies alone to close the universe.

  11. Vacuum vessel for thermonuclear device

    International Nuclear Information System (INIS)

    Kikuchi, Mitsuru; Nagashima, Keisuke; Suzuki, Masaru; Onozuka, Masaki.

    1997-01-01

    A vacuum vessel main body and structural members at the inside and the outside of the vacuum vessel main body are constituted by structural materials activated by irradiation of neutrons from plasmas such as stainless steels. Shielding members comprising tungsten or molybdenum are disposed on the surface of the vacuum vessel main body and the structural members of the inside and the outside of the main body. The shielding members have a function also as first walls or a seat member for the first walls. Armor tiles may be disposed to the shielding members. The shielding members and the armor tiles are secured to a securing seat member disposed, for example, to an inner plate of the vacuum vessel main body by bolts. Since the shielding members are disposed, it is not necessary to constitute the vacuum vessel main body and the structural members at the inside and the outside thereof by using a low activation material which is less activated, such as a titanium alloy. (I.N.)

  12. Vacuum vessel for thermonuclear device

    Energy Technology Data Exchange (ETDEWEB)

    Kikuchi, Mitsuru; Nagashima, Keisuke [Japan Atomic Energy Research Inst., Tokyo (Japan); Suzuki, Masaru; Onozuka, Masaki

    1997-07-11

    A vacuum vessel main body and structural members at the inside and the outside of the vacuum vessel main body are constituted by structural materials activated by irradiation of neutrons from plasmas such as stainless steels. Shielding members comprising tungsten or molybdenum are disposed on the surface of the vacuum vessel main body and the structural members of the inside and the outside of the main body. The shielding members have a function also as first walls or a seat member for the first walls. Armor tiles may be disposed to the shielding members. The shielding members and the armor tiles are secured to a securing seat member disposed, for example, to an inner plate of the vacuum vessel main body by bolts. Since the shielding members are disposed, it is not necessary to constitute the vacuum vessel main body and the structural members at the inside and the outside thereof by using a low activation material which is less activated, such as a titanium alloy. (I.N.)

  13. Vessels in Transit - Web Tool

    Data.gov (United States)

    Department of Transportation — A web tool that provides real-time information on vessels transiting the Saint Lawrence Seaway. Visitors may sort by order of turn, vessel name, or last location in...

  14. High-performance fiber/epoxy composite pressure vessels

    Science.gov (United States)

    Chiao, T. T.; Hamstad, M. A.; Jessop, E. S.; Toland, R. H.

    1978-01-01

    Activities described include: (1) determining the applicability of an ultrahigh-strength graphite fiber to composite pressure vessels; (2) defining the fatigue performance of thin-titanium-lined, high-strength graphite/epoxy pressure vessel; (3) selecting epoxy resin systems suitable for filament winding; (4) studying the fatigue life potential of Kevlar 49/epoxy pressure vessels; and (5) developing polymer liners for composite pressure vessels. Kevlar 49/epoxy and graphite fiber/epoxy pressure vessels, 10.2 cm in diameter, some with aluminum liners and some with alternation layers of rubber and polymer were fabricated. To determine liner performance, vessels were subjected to gas permeation tests, fatigue cycling, and burst tests, measuring composite performance, fatigue life, and leak rates. Both the metal and the rubber/polymer liner performed well. Proportionately larger pressure vessels (20.3 and 38 cm in diameter) were made and subjected to the same tests. In these larger vessels, line leakage problems with both liners developed the causes of the leaks were identified and some solutions to such liner problems are recommended.

  15. Reactor vessel supported by flexure member

    International Nuclear Information System (INIS)

    Crawford, J.D.; Pankow, B.

    1975-01-01

    A description is given of a reactor pressure vessel which is provided with vertical support means in the form of circumferentially spaced columns upon which the vessel is mounted. The columns are adapted to undergo flexure in order to accommodate the thermally induced displacements experienced by the vessel during operational transients

  16. 50 CFR 648.4 - Vessel permits.

    Science.gov (United States)

    2010-10-01

    ... carrying passengers for hire. (8) Atlantic bluefish vessels. (i) Commercial. Any vessel of the United... lands Atlantic bluefish in or from the EEZ in excess of the recreational possession limit specified at § 648.164 must have been issued and carry on board a valid commercial bluefish vessel permit. (ii) Party...

  17. Histomorphological changes of vessel structure in head and neck vessels following preoperative or postoperative radiotherapy

    International Nuclear Information System (INIS)

    Schultze-Mosgau, S.; Wehrhan, F.; Wiltfang, J.; Grabenbauer, G.G.; Sauer, R.; Roedel, F.; Radespiel-Troeger, M.

    2002-01-01

    Patients and Methods: In 348 patients (October 1995-March 2002) receiving primarly or secondarily 356 microvascular hard- and soft tissue reconstruction, a total of 209 vessels were obtained from neck recipient vessels and transplant vessels during anastomosis. Three groups were analysed: group 1 (27 patients) treated with no radiotherapy or chemotherapy; group 2 (29 patients) treated with preoperative irradiation (40-50 Gy) and chemotherapy (800 mg/m 2 /day 5-FU and 20 mg/m 2 /day cisplatin) 1.5 months prior to surgery; group 3 (20 patients) treated with radiotherapy (60-70 Gy) (median interval 78.7 months; IQR: 31.3 months) prior to surgery. From each of the 209 vessel specimens, 3 sections were investigated histomorphometrically, qualitatively and quantitatively (ratio media area/total vessel area) by NIH-Image-digitized measurements. To evaluate these changes as a function of age, radiation dose and chemotherapy, a statistical analysis was performed using an analysis of covariance and χ 2 tests (p > 0.05, SPSS V10). Results: In group 3, qualitative changes (intima dehiscence, hyalinosis) were found in recipient arteries significantly more frequently than in groups 1 and 2. For group 3 recipient arteries, histomorphometry revealed a significant decrease in the ratio media area/total vessel area (median 0.51, IQR 0.10) in comparison with groups 1 (p = 0.02) (median 0.61, IQR 0.29) and 2 (p = 0.046) (median 0.58, IQR 0.19). No significant difference was found between the vessels of groups 1 and 2 (p = 0.48). There were no significant differences in transplant arteries and recipient or transplant veins between the groups. Age and chemotherapy did not appear to have a significant influence on vessel changes in this study (p > 0.05). Conclusions: Following irradiation with 60-70 Gy, significant qualitative and quantitative histological changes to the recipient arteries, but not to the recipient veins, could be observed. In contrast, irradiation at a dose of 40-50 Gy

  18. In-vessel core debris retention through external flooding of the reactor pressure vessel. State-of-the-art report

    Energy Technology Data Exchange (ETDEWEB)

    Heel, A.M.J.M. van

    1995-07-01

    An overview of the state-of-the-art knowledge on the ex-vessel flooding accident management strategy for severe accidents in a NPP has been given. The feasibility has been discussed, as well as the in- and ex-vessel phenomena, which influence the structural integrity of the vessel. Finally, some computer codes with the ability to model the phenomena involved in ex-vessel flooding have been discussed. (orig./HP).

  19. In-vessel core debris retention through external flooding of the reactor pressure vessel. State-of-the-art report

    International Nuclear Information System (INIS)

    Heel, A.M.J.M. van.

    1995-07-01

    An overview of the state-of-the-art knowledge on the ex-vessel flooding accident management strategy for severe accidents in a NPP has been given. The feasibility has been discussed, as well as the in- and ex-vessel phenomena, which influence the structural integrity of the vessel. Finally, some computer codes with the ability to model the phenomena involved in ex-vessel flooding have been discussed. (orig./HP)

  20. Investigation of a weld defect, reactor vessel head Ringhals 2

    International Nuclear Information System (INIS)

    Embring, G.; Pers-Anderson, E.B.

    1994-01-01

    During the summer-outage 1993 Ringhals unit 2 vessel head was inspected at weld-area of Alloy 182. One major defect was found Two plus two ''boat-samples'' were taken out from the zone between the weld and the stainless cladding. All samples were sent to Studsviks laboratories for detailed investigations. The metallographic and fractographic investigations revealed that the major weld-defect had been there from manufacturing. The defect was located between the Alloy 182-buttering and the pressure vessel steel SA 533 grB cl 1. No indications of PWSCC or IDSCC were found. An inspection programme was defined. Different types of reference blocks were provided by Ringhals in cooperation with ABB TRC. Reference reflectors of type flat bottom hole (FBH) and eroded notches (EDM), with different sizes and separation were manufactured. One weld sample with manufacturing defects -lack of fusion and slag was inclusions- was present. ABB TRC performed UT inspection in the gap between the penetration and the thermal sleeve. Inspection results like defect identification, defect separation and defect sizing accuracy were compared with result from the destructive inspection. No relevant additional defects were found. An analysing and repair program was performed. A special designed disc sealed off the defect area. (authors). 5 figs., 3 refs

  1. 19 CFR 4.97 - Salvage vessels.

    Science.gov (United States)

    2010-04-01

    ... United States and Great Britain ‘concerning reciprocal rights for United States and Canada in the... meaning of this statute. (e) A Mexican vessel may engage in a salvage operation on a Mexican vessel in any territorial waters of the United States in which Mexican vessels are permitted to conduct such operations by...

  2. Vacuum vessel for thermonuclear device

    International Nuclear Information System (INIS)

    Hagiwara, Koji; Imura, Yasuya.

    1979-01-01

    Purpose: To provide constituted method for easily performing baking of vacuum vessel, using short-circuiting segments. Constitution: At the time of baking, one turn circuit is formed by the vacuum vessel and short-circuiting segments, and current transformer converting the one turn circuit into a secondary circuit by the primary coil and iron core is formed, and the vacuum vessel is Joule heated by an induction current from the primary coil. After completion of baking, the short-circuiting segments are removed. (Kamimura, M.)

  3. Structural analysis of the KSTAR vacuum vessel

    Energy Technology Data Exchange (ETDEWEB)

    In, Sang Ryul; Yoon, Byeong Joo [Korea Atomic Energy Research Institute, Taejon (Korea)

    1998-10-01

    Structure analysis of the vacuum vessel for the KSTAR tokamak which, is in the end phase of the conceptual design have been performed. Mechanical stresses and deformations of the vessel produced by constant forces due to atmospheric pressure, dead weight, fluid pressure, etc and various transient electromagnetic forces induced during tokamak operations were calculated as well as modal characteristics and buckling properties were investigated. Influences of the temperature gradient and the constraint condition of the support on the thermal stress and deformation of the vessel were analyzed. The thermal stress due to the temperature distribution on the vessel as supplying the N{sub 2} gas of 400 deg C through poloidal channels according to the recent baking concept were calculated. No severe problem in the robustness of the vessel was found when applying the constant pressures on the vessel. However the mechanical stress due to the EM force induced by halo currents flowing on the vessel and the plasma facing components (PFCs) far exceeded the allowable limit. Some reinforcing components should be added on the boundary of the PFC support and the vessel, and that of the vessel support and the vessel. A steep temperature gradient in the vicinity of the inlet and oulet of the heating gas produced a thermal stress much higher than allowable. It is necessary to make the temperature of the vessel as uniform as possible and to develop a new support concept which is flexible enough to accommodate a thermal expansion of a few cm while sufficiently strong to resist mechanical impacts. (author). 5 refs., 41 figs., 9 tabs.

  4. Pressure vessels and methods of sealing leaky tubes disposed in pressure vessels

    International Nuclear Information System (INIS)

    Larson, G.C.

    1980-01-01

    This invention relates to pressure vessels and to methods of sealing leaky tubes in them and is especially applicable to pressure vessels in the form of sheet-and-tube type heat exchangers constructed with a large number of relatively small diameter tubes grouped in a bundle. To seal off a leaky tube in such a heat exchanger an explosive activated plug in the form of a hollow metal body is used, inserted at each end of the tube to be sealed. Using the arrangement of pressure vessel and associated tube sheets and the explosive activated plug method of sealing a leaky tube as described in this invention it is claimed that distortion of the adjacent tubes and the tube sheets is reduced when the explosive activated plugs are detonated. (U.K.)

  5. In-vessel core degradation code validation matrix

    International Nuclear Information System (INIS)

    Haste, T.J.; Adroguer, B.; Gauntt, R.O.; Martinez, J.A.; Ott, L.J.; Sugimoto, J.; Trambauer, K.

    1996-01-01

    The objective of the current Validation Matrix is to define a basic set of experiments, for which comparison of the measured and calculated parameters forms a basis for establishing the accuracy of test predictions, covering the full range of in-vessel core degradation phenomena expected in light water reactor severe accident transients. The scope of the review covers PWR and BWR designs of Western origin: the coverage of phenomena extends from the initial heat-up through to the introduction of melt into the lower plenum. Concerning fission product behaviour, the effect of core degradation on fission product release is considered. The report provides brief overviews of the main LWR severe accident sequences and of the dominant phenomena involved. The experimental database is summarised. These data are cross-referenced against a condensed set of the phenomena and test condition headings presented earlier, judging the results against a set of selection criteria and identifying key tests of particular value. The main conclusions and recommendations are listed. (K.A.)

  6. 33 CFR 151.1512 - Vessel safety.

    Science.gov (United States)

    2010-07-01

    ... 33 Navigation and Navigable Waters 2 2010-07-01 2010-07-01 false Vessel safety. 151.1512 Section... River § 151.1512 Vessel safety. Nothing in this subpart relieves the master of the responsibility for ensuring the safety and stability of the vessel or the safety of the crew and passengers, or any other...

  7. Vitamin D Status in Small Vessel and Large Vessel Ischemic Stroke Patients: A Case–control Study

    Directory of Open Access Journals (Sweden)

    Navid Manouchehri

    2017-01-01

    Full Text Available Background: Vitamin D insufficiency is a globally widespread issue. Recent studies have reported a high prevalence of Vitamin D deficiency in Middle-East countries. Studies have shown negative effects of Vitamin D deficiency on endothelium and related diseases such as ischemic brain stroke. Here, we assessed Vitamin D status in patients with different types of ischemic brain stroke and control group. Materials and Methods: Seventy-five patients (49.3% small vessel, 50.7% large vessel and 75 controls, matched for age (68.01 ± 10.94 vs. 67.64 ± 10.24 and sex (42 male and 33 female were recruited. 25(OH D levels were measured by Chemiluminescence immunoassay. 25(OH D status was considered as severely, moderately, or mildly deficient and normal with 25(OH D levels of less than 5, 5-10, 10-16, and> 16 ng/ml, respectively. Results: Mean ± standard error concentration of 25(OH D in cases and controls were 17.7 ± 1.5 and 26.9 ± 1.6 (P = 0.0001, respectively. Mild, moderate, and severe Vitamin D deficiency were observed in 10.8%, 32.4%, 8.1% vs. 34.3%, 31.5%, 9.5% of small vessel and large vessel group, respectively. 21.7% of the controls were Vitamin D deficient. Vitamin D deficiency was significantly associated with higher risk for ischemic stroke, (P = 0.000, OR = 7.17, 95% confidence interval: 3.36–15.29. 25(OH D levels were significantly higher in control group comparing to small vessel (26.9 ± 1.6 vs. 20.59 ± 2.6 P < 0.05 and large vessel (26.9 ± 1.6 vs. 13.4 ± 1.3 P < 0.001 stroke patients. Small vessel group had significantly higher levels of Vitamin D than large vessel (P < 0.05. Conclusion: Vitamin D deficiency significantly increases the risk of ischemic stroke, favoring the types with the pathogenesis of large vessel strokes.

  8. AFSC/FMA/Vessel Assessment Logging

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Vessels fishing trawl gear, vessels fishing hook-and-line and pot gear that are also greater than 57.5 feet overall, and shoreside and floating processing facilities...

  9. Integrated leak rate test results of JOYO reactor containment vessel

    International Nuclear Information System (INIS)

    Tamura, M.; Endo, J.

    1982-02-01

    Integrated leak rate tests of JOYO after the reactor coolant system had been filled with sodium have been performed two times since 1978 (February 1978 and December 1979). The tests were conducted with the in-containment sodium systems, primary argon cover gas system and air conditioning systems operating. Both the absolute pressure method and the reference chamber method were employed during the test. The results of both tests confirmed the functioning of the containment vessel, and leak rate limits were satisfied. In Addition, the adequancy of the test instrumentation system and the test method was demonstrated. Finally the plant conditions required to maintain reasonable accuracy for the leak rate testing of LMFBR were established. In this paper, the test conditions and the test results are described. (author)

  10. Manufacturing technology development for vacuum vessel and plasma facing components

    International Nuclear Information System (INIS)

    Laitinen, Arttu; Liimatainen, Jari; Hallila, Pentti

    2005-01-01

    Vacuum vessel and plasma facing components of the ITER construction including shield modules and primary first wall panels have great impact on the production costs and reliability of the installation. From the manufacturing technology point of view, accuracy of shape, properties of the various austenitic stainless steel/austenitic stainless steel interfaces or CuCrZr/austenitic stainless steel interfaces as well as those of the base materials are crucial for technical reliability of the construction. The current approach in plasma facing components has been utilisation of solid-HIP technology and solid-powder-HIP technology. Due to the large size of especially shield modules shape, control of the internal cavities and cooling channels is extremely demanding. This requires strict control of the raw materials and manufacturing parameters

  11. Assessment of reactor vessel integrity (ARVI)

    Energy Technology Data Exchange (ETDEWEB)

    Sehgal, B.R. E-mail: sehgal@ne.kth.se; Theerthan, A.; Giri, A.; Karbojian, A.; Willschuetz, H.G.; Kymaelaeinen, O.; Vandroux, S.; Bonnet, J.M.; Seiler, J.M.; Ikkonen, K.; Sairanen, R.; Bhandari, S.; Buerger, M.; Buck, M.; Widmann, W.; Dienstbier, J.; Techy, Z.; Kostka, P.; Taubner, R.; Theofanous, T.; Dinh, T.N

    2003-04-01

    The cost-shared project ARVI (assessment of reactor vessel integrity) involves a total of nine organisations from Europe and USA. The objective of the ARVI Project is to resolve the safety issues that remain unresolved for the melt vessel interaction phase of the in-vessel progression of a severe accident. The work consists of experiments and analysis development. Four tests were performed in the EC-FOREVER Programme, in which failure was achieved in-vessels employing the French pressure vessel steel. The tests were analysed with the commercial code ANSYS-Multiphysics, and the codes SYSTUS+ and PASULA, and quite good agreement was achieved for the failure location. Natural convection experiments in stratified pools have been performed in the SIMECO and the COPO facilities, which showed that much greater heat is transferred downwards for immiscible layers or before layers mix. A model for gap cooling and a set of simplified models for the system codes have been developed. MVITA code calculations have been performed for the Czech and Hungarian VVERs, towards evaluation of the in-vessel melt retention accident management scheme. Tests have been performed at the ULPU facility with organised flow for vessel external cooling. Considerable enhancement of the critical heat flux (CHF) was obtained. The ARVI Project has reached the halfway stage. This paper presents the results obtained thus far from the project.

  12. Neutron Assay System for Confinement Vessel Disposition

    International Nuclear Information System (INIS)

    Frame, Katherine C.; Bourne, Mark M.; Crooks, William J.; Evans, Louise; Mayo, Douglas R.; Miko, David K.; Salazar, William R.; Stange, Sy; Valdez, Jose I.; Vigil, Georgiana M.

    2012-01-01

    Los Alamos National Laboratory has a number of spherical confinement vessels (CVs) remaining from tests involving nuclear materials. These vessels have an inner diameter of 6 feet with 1-inch thick steel walls. The goal of the Confinement Vessel Disposition (CVD) project is to remove debris and reduce contamination inside the CVs. The Confinement Vessel Assay System (CVAS) was developed to measure the amount of special nuclear material (SNM) in CVs before and after cleanout. Prior to cleanout, the system will be used to perform a verification measurement of each vessel. After cleanout, the system will be used to perform safeguards-quality assays of (le)100-g 239 Pu equivalent in a vessel for safeguards termination. The CVAS has been tested and calibrated in preparation for verification and safeguards measurements.

  13. Containment vessel

    International Nuclear Information System (INIS)

    Zbirohowski-Koscia, K.F.; Roberts, A.C.

    1980-01-01

    A concrete containment vessel for nuclear reactors is disclosed that is spherical and that has prestressing tendons disposed in first, second and third sets, the tendons of each set being all substantially concentric and centred around a respective one of the three orthogonal axes of the sphere; the tendons of the first set being anchored at each end at a first anchor rib running around a circumference of the vessel, the tendons of the second set being anchored at each end at a second anchor rib running around a circumference of the sphere and disposed at 90 0 to the first rib, and the tendons of the third set being anchored some to the first rib and the remainder to the second rib. (author)

  14. Accuracy of ultrasonography in the detection of severe hepatic lipidosis in cats.

    Science.gov (United States)

    Yeager, A E; Mohammed, H

    1992-04-01

    The accuracy of ultrasonography in detection of feline hepatic lipidosis was studied retrospectively. The following ultrasonographic criteria were associated positively with severe hepatic lipidosis: the liver hyperechoic, compared with falciform fat; the liver isoechoic or hyperechoic, compared with omental fat; poor visualization of intrahepatic vessel borders; and increased attenuation of sound by the liver. In a group of 36 cats with clinically apparent hepatobiliary disease and in which liver biopsy was done, liver hyperechoic, compared with falciform fat, was the best criterion for diagnosis of severe hepatic lipidosis with 91% sensitivity, 100% specificity, and 100% positive predictive value.

  15. Improved vessel morphology measurements in contrast-enhanced multi-detector computed tomography coronary angiography with non-linear post-processing

    International Nuclear Information System (INIS)

    Ferencik, Maros; Lisauskas, Jennifer B.; Cury, Ricardo C.; Hoffmann, Udo; Abbara, Suhny; Achenbach, Stephan; Karl, W. Clem; Brady, Thomas J.; Chan, Raymond C.

    2006-01-01

    Multi-detector computed tomography (MDCT) permits detection of coronary plaque. However, noise and blurring impair accuracy and precision of plaque measurements. The aim of the study was to evaluate MDCT post-processing based on non-linear image deblurring and edge-preserving noise suppression for measurements of plaque size. Contrast-enhanced MDCT coronary angiography was performed in four subjects (mean age 55 ± 5 years, mean heart rate 54 ± 5 bpm) using a 16-slice scanner (Siemens Sensation 16, collimation 16 x 0.75 mm, gantry rotation 420 ms, tube voltage 120 kV, tube current 550 mAs, 80 mL of contrast). Intravascular ultrasound (IVUS; 40 MHz probe) was performed in one vessel in each patient and served as a reference standard. MDCT vessel cross-sectional images (1 mm thickness) were created perpendicular to centerline and aligned with corresponding IVUS images. MDCT images were processed using a deblurring and edge-preserving noise suppression algorithm. Then, three independent blinded observers segmented lumen and outer vessel boundaries in each modality to obtain vessel cross-sectional area and wall area in the unprocessed MDCT cross-sections, post-processed MDCT cross-sections and corresponding IVUS. The wall area measurement difference for unprocessed and post-processed MDCT images relative to IVUS was 0.4 ± 3.8 mm 2 and -0.2 ± 2.2 mm 2 (p 2 , respectively. In conclusion, MDCT permitted accurate in vivo measurement of wall area and vessel cross-sectional area as compared to IVUS. Post-processing to reduce blurring and noise reduced variability of wall area measurements and reduced measurement bias for both wall area and vessel cross-sectional area

  16. Integral experiments on in-vessel coolability and vessel creep: results and analysis of the FOREVER-C1 test

    Energy Technology Data Exchange (ETDEWEB)

    Sehgal, B.R.; Nourgaliev, R.R.; Dinh, T.N.; Karbojian, A. [Division of Nuclear Power Safety, Royal Institute of Technology, Drottning Kristinas Vaeg., Stockholm (Sweden)

    1999-07-01

    This paper describes the FOREVER (Failure Of REactor VEssel Retention) experimental program, which is currently underway at the Division of Nuclear Power Safety, Royal Institute of Technology (RIT/NPS). The objectives of the FOREVER experiments are to obtain data and develop validated models (i) on the melt coolability process inside the vessel, in the presence of water (in particular, on the efficacy of the postulated gap cooling to preclude vessel failure); and (ii) on the lower head failure due to the creep process in the absence of water inside and/or outside the lower head. The paper presents the experimental results and analysis of the first FOREVER-C1 test. During this experiment, the 1/10th scale pressure vessel, heated to about 900degC and pressurized to 26 bars, was subjected to creep deformation in a non-stop 24-hours test. The vessel wall displacement data clearly shows different stages of the vessel deformation due to thermal expansion, elastic, plastic and creep processes. The maximum displacement was observed at the lowermost region of the vessel lower plenum. Information on the FOREVER-C1 measured thermal characteristics and analysis of the observed thermal and structural behavior is presented. The coupled nature of thermal and mechanical processes, as well as the effect of other system conditions (such as depressurization) on the melt pool and vessel temperature responses are analyzed. (author)

  17. Pressure vessel integrity 1991

    International Nuclear Information System (INIS)

    Bhandari, S.; Doney, R.O.; McDonald, M.S.; Jones, D.P.; Wilson, W.K.; Pennell, W.E.

    1991-01-01

    This volume contains papers relating to the structural integrity assessment of pressure vessels and piping, with special emphasis on nuclear industry applications. The papers were prepared for technical sessions developed under the sponsorship of the ASME Pressure Vessels and Piping Division Committees for Codes and Standards, Computer Technology, Design and Analysis, and Materials Fabrication. They were presented at the 1991 Pressure Vessels and Piping Division Conference in San Diego, California, June 23-27. The primary objective of the sponsoring organization is to provide a forum for the dissemination and discussion of information on development and application of technology for the structural integrity assessment of pressure vessels and piping. This publication includes contributions from authors from Australia, France, Japan, Sweden, Switzerland, the United Kingdom, and the United States. The papers here are organized in six sections, each with a particular emphasis as indicated in the following section titles: Fracture Technology Status and Application Experience; Crack Initiation, Propagation and Arrest; Ductile Tearing; Constraint, Stress State, and Local-Brittle-Zones Effects; Computational Techniques for Fracture and Corrosion Fatigue; and Codes and Standards for Fatigue, Fracture and Erosion/Corrosion

  18. Test of 6-in.-thick pressure vessels. Series 3: intermediate test vessel V-7A under sustained loading

    International Nuclear Information System (INIS)

    Bryan, R.H.; Cate, T.M.; Holz, P.P.; King, T.A.; Merkle, J.G.; Robinson, G.C.; Smith, G.C.; Smith, J.E.; Whitman, G.D.

    1978-01-01

    HSST intermediate test vessel V-7 was repaired after being tested hydrostatically to leakage and was retested pneumatically as vessel V-7A. Except for the method of applying the load, the conditions in both tests were nearly identical. In each case, a sharp outside surface flaw 547 mm long (18 in.) by about 135 mm deep (5.3 in.) was prepared in the 152-mm-thick (6-in.) test cylinder of A533, grade B, class 1 steel. The inside surface of vessel V-7A was sealed in the region of the flaw by a thin metal patch so that pressure could be sustained after rupture. Vessel V-7A failed by rupture of the flaw ligament without burst, as expected. Rupture occurred at 144.3 MPa (20.92 ksi), after which pressure was sustained for 30 min without any indication of instability. The rupture pressure of vessel V-7A was about 2 percent less than that of vessel V-7

  19. Graywater Discharges from Vessels

    Science.gov (United States)

    2011-11-01

    metals (e.g., cadmium, chromium, lead, copper , zinc, silver, nickel, and mercury), solids, and nutrients (USEPA, 2008b; USEPA 2010). Wastewater from... flotation ), and disinfection (using ultraviolet light) as compared to traditional Type II MSDs that use either simple maceration and chlorination, or...Coliform Naval Vessels Oceanographic Vessels Small Cruise Ships 25a Vendor 2 Hamann AG Biological Treatment with Dissolved Air Flotation and

  20. Reactor vessel decommissioning project. Final report

    International Nuclear Information System (INIS)

    Schoonen, D.H.

    1984-09-01

    This report describes a reactor vessel decommissioning project; it documents and explains the project objectives, scope, performance results, and sodium removal process. The project was successfully completed in FY-1983, within budget and without significant problems or adverse impact on the environment. Waste generated by the operation included the reactor vessel, drained sodium, and liquid, solid, and gaseous wastes which were significantly less than project estimates. Personnel radiation exposures were minimized, such that the project total was one-half the predicted exposure level. Except for the sodium removed, the material remaining in the reactor vessel is essentially the same as when the vessel arrived for processing

  1. Electrical discharge machining for vessel sample removal

    International Nuclear Information System (INIS)

    Litka, T.J.

    1993-01-01

    Due to aging-related problems or essential metallurgy information (plant-life extension or decommissioning) of nuclear plants, sample removal from vessels may be required as part of an examination. Vessel or cladding samples with cracks may be removed to determine the cause of cracking. Vessel weld samples may be removed to determine the weld metallurgy. In all cases, an engineering analysis must be done prior to sample removal to determine the vessel's integrity upon sample removal. Electrical discharge machining (EDM) is being used for in-vessel nuclear power plant vessel sampling. Machining operations in reactor coolant system (RCS) components must be accomplished while collecting machining chips that could cause damage if they become part of the flow stream. The debris from EDM is a fine talclike particulate (no chips), which can be collected by flushing and filtration

  2. Nuclear power plant pressure vessels. Inservice inspections

    International Nuclear Information System (INIS)

    1995-01-01

    The requirements for the planning and reporting of inservice inspections of nuclear power plant pressure vessels are presented. The guide specifically applies to inservice inspections of Safety class 1 and 2 nuclear power plant pressure vessels, piping, pumps and valves plus their supports and reactor pressure vessel internals by non- destructive examination methods (NDE). Inservice inspections according to the Pressure Vessel Degree (549/73) are discussed separately in the guide YVL 3.0. (4 refs.)

  3. Offshore wind transport and installation vessel

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2001-07-01

    The initial objective of the project was to complete a feasibility study to determine the viability of an innovative transportation vessel to be deployed in the installation of offshore wind farms. This included the feasibility of providing a stable-working platform that can be used in harsh offshore environments. A study of current installation contractors and their installation equipment was used to provide a preliminary specification for the installation vessel. A typical barge was selected and a number of hydrodynamic analyses were carried out in order to establish it's on course and operational stability. The analysis proved the stability of the vessel during operation was critical and that in order to utilise the crane's full potential a stabilisation system must be employed. The main aim of the work to date was to establish whether it was feasible to use a stabilisation system on the installation vessel. The spud leg FEED study established that it was feasible to use spud legs to stabilise the vessel. In order to achieve the degree of stability required it is necessary to lift the vessel completely out of the water. This was not the original aim of the study but due to the external loads on the hull it was the only viable option. Lifting the vessel out of the water results in the legs and leg casings becoming very large. This has a number of consequences for the final design. Due to large loads on the legs spud cans must be used to avoid bottom penetration, the spud cans increase the draft of the vessel by 2m. The large loads require larger winches and more reeving to be used, this results in larger pumps and motors, all of which have to be housed. The stabilisation system has been proved to be feasible for a large installation vessel, the cost and physical size are however more excessive than first anticipated. (Author)

  4. Noninvasive identification of left main and triple vessel coronary artery disease: improved accuracy using quantitative analysis of regional myocardial stress distribution and washout of thallium-201

    International Nuclear Information System (INIS)

    Maddahi, J.; Abdulla, A.; Garcia, E.V.; Swan, H.J.; Berman, D.S.

    1986-01-01

    The capabilities of visual and quantitative analysis of stress redistribution thallium-201 scintigrams, exercise electrocardiography and exercise blood pressure response were compared for correct identification of extensive coronary disease, defined as left main or triple vessel coronary artery disease, or both (50% or more luminal diameter coronary narrowing), in 105 consecutive patients with suspected coronary artery disease. Extensive disease was present in 56 patients and the remaining 49 had either less extensive coronary artery disease (n = 34) or normal coronary arteriograms (n = 15). Although exercise blood pressure response, exercise electrocardiography and visual thallium-201 analysis were highly specific (98, 88 and 96%, respectively), they were insensitive for identification of patients with extensive disease (14, 45 and 16%, respectively). Quantitative thallium-201 analysis significantly improved the sensitivity of visual thallium-201 analysis for identification of patients with extensive disease (from 16 to 63%, p less than 0.001) without a significant loss of specificity (96 versus 86%, p = NS). Eighteen (64%) of the 28 patients who were misclassified by visual analysis as having less extensive disease were correctly classified as having extensive disease by virtue of quantitative analysis of regional myocardial thallium-201 washout. When the results of quantitative thallium-201 analysis were combined with those of blood pressure and electrocardiographic response to exercise, the sensitivity and specificity for identification of patients with extensive disease was 86 and 76%, respectively, and the highest overall accuracy (0.82) was obtained

  5. 46 CFR 15.405 - Familiarity with vessel characteristics.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 1 2010-10-01 2010-10-01 false Familiarity with vessel characteristics. 15.405 Section... MANNING REQUIREMENTS Manning Requirements; All Vessels § 15.405 Familiarity with vessel characteristics. Each credentialed individual must become familiar with the relevant characteristics of the vessel on...

  6. Estimation of center line and diameter of brain blood vessel using three-dimensional blood vessel matching method with head three-dimensional CTA image

    International Nuclear Information System (INIS)

    Maekawa, Masashi; Shinohara, Toshihiro; Nakayama, Masato; Nakasako, Noboru

    2010-01-01

    To support and automate the brain blood vessel disease diagnosis, a novel method to obtain the center line and the diameter of a blood vessel is proposed with a three-dimensional head computed tomographic angiography (CTA) image. Although the line thinning processing with distance transform or gray information is generally used to obtain the blood vessel center line, this method is not essentially one to obtain the center line and tends to yield extra lines depending on CTA images. In this study, the center line of the blood vessel is obtained by tracing the vessel. The blood vessel is traced by sequentially estimating the center point and direction of the blood vessel. The center point and direction of the blood vessel are estimated by taking the correlation between the blood vessel and a solid model of the blood vessel that is designed by considering noise influence. In addition, the vessel diameter is also estimated by correlating the blood vessel and the blood vessel model of which the diameter is variable. The validity of the proposed method is confirmed by experimentally applied the proposed method to an actual three-dimensional head CTA image. (author)

  7. Design of the ITER vacuum vessel

    International Nuclear Information System (INIS)

    Ioki, K.; Johnson, G.; Shimizu, K.; Williamson, D.

    1995-01-01

    The ITER vacuum vessel is a major safety barrier and must support electromagnetic loads during plasma disruptions and vertical displacement events (VDE) and withstand plausible accidents without losing confinement.The vacuum vessel has a double wall structure to provide structural and electrical continuity in the toroidal direction. The inner and outer shells and poloidal stiffening ribs between them are joined by welding, which gives the vessel the required mechanical strength. The space between the shells will be filled with steel balls and plate inserts to provide additional nuclear shielding. Water flowing in this space is required to remove nuclear heat deposition, which is 0.2-2.5% of the total fusion power. The minor and major radii of the tokamak are 3.9 m and 13 m respectively, and the overall height is 15 m. The total thickness of the vessel wall structure is 0.4-0.7 m.The inboard and outboard blanket segments are supported from the vacuum vessel. The support structure is required to withstand a large total vertical force of 200-300 MN due to VDE and to allow for differential thermal expansion.The first candidate for the vacuum vessel material is Inconel 625, due to its higher electric resistivity and higher yield strength, even at high temperatures. Type 316 stainless steel is also considered a vacuum vessel material candidate, owing to its large database and because it is supported by more conventional fabrication technology. (orig.)

  8. Prediction of left main or 3-vessel disease using myocardial perfusion reserve on dynamic thallium-201 single-photon emission computed tomography with a semiconductor gamma camera.

    Science.gov (United States)

    Shiraishi, Shinya; Sakamoto, Fumi; Tsuda, Noriko; Yoshida, Morikatsu; Tomiguchi, Seiji; Utsunomiya, Daisuke; Ogawa, Hisao; Yamashita, Yasuyuki

    2015-01-01

    Myocardial perfusion imaging (MPI) may fail to detect balanced ischemia. We evaluated myocardial perfusion reserve (MPR) using Tl dynamic single-photon emission computed tomography (SPECT) and a novel cadmium zinc telluride (CZT) camera for predicting 3-vessel or left main coronary artery disease (CAD). METHODS AND RESULTS: A total of 55 consecutive patients with suspected CAD underwent SPECT-MPI and coronary angiography. The MPR index was calculated using the standard 2-compartment kinetic model. We analyzed the utility of MPR index, other SPECT findings, and various clinical variables. On multivariate analysis, MPR index and history of previous myocardial infarction (MI) predicted left main and 3-vessel disease. The area under the receiver operating characteristic curve was 0.81 for MPR index, 0.699 for history of previous MI, and 0.86 for MPR index plus history of previous MI. MPR index ≤1.5 yielded the highest diagnostic accuracy. Sensitivity, specificity, and accuracy were 86%, 78%, and 80%, respectively, for MPR index, 64%, 76%, 73% for previous MI, and 57%, 93%, and 84% for MPR index plus history of previous MI. Quantification of MPR using dynamic SPECT and a novel CZT camera may identify balanced ischemia in patients with left main or 3-vessel disease.

  9. No evidence for an open vessel effect in centrifuge-based vulnerability curves of a long-vesselled liana (Vitis vinifera).

    Science.gov (United States)

    Jacobsen, Anna L; Pratt, R Brandon

    2012-06-01

    Vulnerability to cavitation curves are used to estimate xylem cavitation resistance and can be constructed using multiple techniques. It was recently suggested that a technique that relies on centrifugal force to generate negative xylem pressures may be susceptible to an open vessel artifact in long-vesselled species. Here, we used custom centrifuge rotors to measure different sample lengths of 1-yr-old stems of grapevine to examine the influence of open vessels on vulnerability curves, thus testing the hypothesized open vessel artifact. These curves were compared with a dehydration-based vulnerability curve. Although samples differed significantly in the number of open vessels, there was no difference in the vulnerability to cavitation measured on 0.14- and 0.271-m-long samples of Vitis vinifera. Dehydration and centrifuge-based curves showed a similar pattern of declining xylem-specific hydraulic conductivity (K(s)) with declining water potential. The percentage loss in hydraulic conductivity (PLC) differed between dehydration and centrifuge curves and it was determined that grapevine is susceptible to errors in estimating maximum K(s) during dehydration because of the development of vessel blockages. Our results from a long-vesselled liana do not support the open vessel artifact hypothesis. © 2012 The Authors. New Phytologist © 2012 New Phytologist Trust.

  10. Test of 6-inch-thick pressure vessels. Series 2. Intermediate test vessels V-3, V-4, and V-6

    International Nuclear Information System (INIS)

    Bryan, R.H.; Merkle, J.G.; Raftenberg, M.N.; Robinson, G.C.; Smith, J.E.

    1975-11-01

    The second series of intermediate vessel tests were crack initiation fracture tests of 6-in.-thick 39-in.-OD steel vessels with sharp surface flaws approximately 2 1 / 2 in. deep by 8 in. long in the longitudinal weld seams of the test cylinders. Fracture was initiated by means of hydraulic pressurization. One vessel was tested at each of three temperatures: 75, 130, and 190 0 F. Pretest analyses were made to predict the failure pressures and strains. Fracture toughness data obtained by equivalent-energy analysis of precracked Charpy-V tests and compact-tension specimen tests were used in the fracture analyses. The vessels behaved generally as had been expected. Posttest fracture analyses were also performed for each vessel. Detailed discussions of the fracture analysis methods developed in support of the vessel tests described are included. 34 references

  11. PWR vessel inspection performance improvements

    International Nuclear Information System (INIS)

    Blair Fairbrother, D.; Bodson, Francis

    1998-01-01

    A compact robot for ultrasonic inspection of reactor vessels has been developed that reduces setup logistics and schedule time for mandatory code inspections. Rather than installing a large structure to access the entire weld inspection area from its flange attachment, the compact robot examines welds in overlapping patches from a suction cup anchor to the shell wall. The compact robot size allows two robots to be operated in the vessel simultaneously. This significantly reduces the time required to complete the inspection. Experience to date indicates that time for vessel examinations can be reduced to fewer than four days. (author)

  12. TPX vacuum vessel transient thermal and stress conditions

    International Nuclear Information System (INIS)

    Feldshteyn, Y.; Dinkevich, S.; Feng, T.; Majumder, D.

    1995-01-01

    The TPX vacuum vessel provides the vacuum boundary for the plasma and the mechanical support for the internal components. Another function of the vacuum vessel is to contain neutron shielding water in the double wall space during normal operation. This double wall space serves as a heat reservoir for the entire vacuum vessel during bakeout. The vacuum vessel and the internal components are subjected to thermal stresses induced by a nonuniform temperature distribution within the structure during bakeout. A successful Conceptual Design Review in March 1993 has established superheated steam as the heating source of the vacuum vessel. A transient bakeout mode of the vacuum vessel and in-vessel components has been analyzed to evaluate transient period duration, proper temperature level, actual thermal stresses and performance of the steam equipment. Thermally, the vacuum vessel structure may be considered as an adiabatic system because it is perfectly insulated by the strong surrounding vacuum and multiple layers of superinsulation. Important aspects of the analysis are described herein

  13. In service inspection of SUPERPHENIX 1 vessels: MIR

    International Nuclear Information System (INIS)

    Asty, M.; Viard, J.; Lerat, B.; Saglio, R.

    1985-01-01

    Although no in-service inspection constraints were imposed on the Phenix vessels, the Safety Authorities asked that the design of SUPERPHENIX 1 makes it possible to monitor throughout the lifetime of the reactor, surface and internal defects on the main vessel. A pool design and the presence of heat baffles inside the main vessel make access from the inside of the vessel impossible. Thus, an inspection can only be performed from the outside of the main vessel: the distance between the walls of the main and safety vessels is such that an inspection device can be introduced into the corresponding space. As the design of the reactor precludes radiographic inspection, the method which was selected for monitoring internal defects in the main vessel is ultrasonics. However, the anisotropic structure of austenitic stainless steel welds limits the performance of this technique. The authors present the in-service inspection device, MIR, which has been specially developed for the visual and ultrasonic examination of SUPERPHENIX 1 vessels

  14. Final report for the 2nd Ex-Vessel Neutron Dosimetry Installations and Evaluations for Yonggwang Unit 2 Reactor Pressure Vessel

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Byoung Chul; Yoo, Choon Sung; Lee, Sam Lai; Gong, Un Sik; Choi, Kwon Jae; Chung, Kyoung Ki; Kim, Kwan Hyun; Chang, Jong Hwa; Ha, Jea Ju

    2008-01-15

    This report describes a neutron fluence assessment performed for the Yonggwang Unit 2 pressure vessel beltline region based on the guidance specified in Regulatory Guide 1.190. In this assessment, maximum fast neutron exposures expressed in terms of fast neutron fluence (E>1 MeV) and iron atom displacements (dpa) were established for the beltline region of the pressure vessel. During Cycle 16 of reactor operation, an Ex-Vessel Neutron Dosimetry Program was instituted at Yonggwang Unit 2 to provide continuous monitoring of the beltline region of the reactor vessel. The use of the Ex-Vessel Neutron Dosimetry Program coupled with available surveillance capsule measurements provides a plant specific data base that enables the evaluation of the vessel exposure and the uncertainty associated with that exposure over the service life of the unit. Ex-Vessel Neutron Dosimetry has been evaluated at the conclusion of Cycle 16.

  15. Final report for the 1st ex-vessel neutron dosimetry installations and evaluations for Kori unit 2 reactor pressure vessel

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Byoung Chul; Yoo, Choon Sung; Lee, Sam Lai; Chang, Kee Ok; Gong, Un Sik; Choi, Kwon Jae; Chang, Jong Hwa; Lim, Nam Jin; Hong, Joon Wha; Cheon, Byeong Jin

    2006-11-15

    This report describes a neutron fluence assessment performed for the Kori unit 2 pressure vessel belt line region based on the guidance specified in regulatory guide 1.190. In this assessment, maximum fast neutron exposures expressed in terms of fast neutron fluence (E>1 MeV) and iron atom displacements (dpa) were established for the belt line region of the pressure vessel. During cycle 20 of reactor operation, an ex-vessel neutron dosimetry program was instituted at Kori unit 2 to provide continuous monitoring of the belt line region of the reactor vessel. The use of the ex-vessel neutron dosimetry program coupled with available surveillance capsule measurements provides a plant specific data base that enables the evaluation of the vessel exposure and the uncertainty associated with that exposure over the service life of the unit. Ex-vessel neutron dosimetry has been evaluated at the conclusion of cycle 20.

  16. Final Report of the 2nd Ex-Vessel Neutron Dosimetry Installation And Evaluations for Yonggwang Unit 1 Reactor Pressure Vessel

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Byoung Chul; Yoo, Choon Sung; Lee, Sam Lai; Chang, Kee Ok; Gong, Un Sik; Choi, Kwon Jae; Chang, Jong Hwa; Li, Nam Jin; Hong, Joon Wha

    2007-01-15

    This report describes a neutron fluence assessment performed for the Yonggwang Unit 1 pressure vessel belt line region based on the guidance specified in Regulatory Guide 1.190. In this assessment, maximum fast neutron exposures expressed in terms of fast neutron fluence (E>1 MeV) and iron atom displacements (dpa) were established for the belt line region of the pressure vessel. During Cycle 16 of reactor operation, 2nd Ex-Vessel Neutron Dosimetry Program was instituted at Yonggwang Unit 1 to provide continuous monitoring of the belt line region of the reactor vessel. The use of the Ex-Vessel Neutron Dosimetry Program coupled with available surveillance capsule measurements provides a plant specific data base that enables the evaluation of the vessel exposure and the uncertainty associated with that exposure over the service life of the unit. Ex-Vessel Neutron Dosimetry has been evaluated at the conclusion of Cycle 16.

  17. Final Report of the 2nd Ex-Vessel Neutron Dosimetry Installation And Evaluations for Yonggwang Unit 1 Reactor Pressure Vessel

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Byoung Chul; Yoo, Choon Sung; Lee, Sam Lai; Gong, Un Sik; Choi, Kwon Jae; Chung, Kyoung Ki; Kim, Kwan Hyun; Chang, Jong Hwa; Ha, Jea Ju

    2008-01-15

    This report describes a neutron fluence assessment performed for the Kori Unit 2 pressure vessel belt line region based on the guidance specified in Regulatory Guide 1.190. In this assessment, maximum fast neutron exposures expressed in terms of fast neutron fluence (E>1 MeV) and iron atom displacements (dpa) were established for the belt line region of the pressure vessel. During Cycle 21 of reactor operation, an Ex-Vessel Neutron Dosimetry Program was instituted at Kori Unit 2 to provide continuous monitoring of the belt line region of the reactor vessel. The use of the Ex-Vessel Neutron Dosimetry Program coupled with available surveillance capsule measurements provides a plant specific data base that enables the evaluation of the vessel exposure and the uncertainty associated with that exposure over the service life of the unit. Ex-Vessel Neutron Dosimetry has been evaluated at the conclusion of Cycle 21.

  18. Final report for the 1st ex-vessel neutron dosimetry installation and evaluations for Kori unit 4 reactor pressure vessel

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Byoung Chul; Yoo, Choon Sung; Lee, Sam Lai; Chang, Kee Ok; Gong, Un Sik; Choi, Kwon Jae; Chang, Jong Hwa; Lim, Nam Jin; Hong, Joon Wha; Cheon, Byeong Jin

    2006-11-15

    This report describes a neutron fluence assessment performed for the Kori unit 4 pressure vessel belt line region based on the guidance specified in regulatory guide 1.190. In this assessment, maximum fast neutron exposures expressed in terms of fast neutron fluence (E>1 MeV) and iron atom displacements (dpa) were established for the belt line region of the pressure vessel. During cycle 16 of reactor operation, an ex-vessel neutron dosimetry program was instituted at Kori unit 4 to provide continuous monitoring of the belt line region of the reactor vessel. The use of the ex-vessel neutron dosimetry program coupled with available surveillance capsule measurements provides a plant specific data base that enables the evaluation of the vessel exposure and the uncertainty associated with that exposure over the service life of the unit. Ex-vessel neutron dosimetry has been evaluated at the conclusion of cycle 16.

  19. Confinement Vessel Assay System: Calibration and Certification Report

    Energy Technology Data Exchange (ETDEWEB)

    Frame, Katherine C. [Los Alamos National Laboratory; Bourne, Mark M. [Los Alamos National Laboratory; Crooks, William J. [Los Alamos National Laboratory; Evans, Louise [Los Alamos National Laboratory; Gomez, Cipriano [Retired CMR-OPS: OPERATIONS; Mayo, Douglas R. [Los Alamos National Laboratory; Miko, David K. [Los Alamos National Laboratory; Salazar, William R. [Los Alamos National Laboratory; Stange, Sy [Los Alamos National Laboratory; Vigil, Georgiana M. [Los Alamos National Laboratory

    2012-07-17

    Los Alamos National Laboratory has a number of spherical confinement vessels (CVs) remaining from tests involving nuclear materials. These vessels have an inner diameter of 6 feet with 1 to 2 inch thick steel walls. The goal of the Confinement Vessel Disposition (CVD) project is to remove debris and reduce contamination inside the vessels. The Confinement Vessel Assay System (CVAS) was developed to measure the amount of SNM in CVs before and after cleanout. Prior to cleanout, the system will be used to perform a verification measurement of each vessel. After cleanout, the system will be used to perform safeguards-quality assays of {le} 100-g {sup 239}Pu equivalent in a vessel for safeguards termination. The system was calibrated in three different mass regions (low, medium, and high) to cover the entire plutonium mass range that will be assayed. The low mass calibration and medium mass calibration were verified for material positioned in the center of an empty vessel. The systematic uncertainty due to position bias was estimated using an MCNPX model to simulate the response of the system to material localized at various points along the inner surface of the vessel. The background component due to cosmic ray spallation was determined by performing measurements of an empty vessel and comparing to measurements in the same location with no vessel present. The CVAS has been tested and calibrated in preparation for verification and safeguards measurements of CVs before and after cleanout.

  20. Confinement Vessel Assay System: Calibration and Certification Report

    International Nuclear Information System (INIS)

    Frame, Katherine C.; Bourne, Mark M.; Crooks, William J.; Evans, Louise; Gomez, Cipriano; Mayo, Douglas R.; Miko, David K.; Salazar, William R.; Stange, Sy; Vigil, Georgiana M.

    2012-01-01

    Los Alamos National Laboratory has a number of spherical confinement vessels (CVs) remaining from tests involving nuclear materials. These vessels have an inner diameter of 6 feet with 1 to 2 inch thick steel walls. The goal of the Confinement Vessel Disposition (CVD) project is to remove debris and reduce contamination inside the vessels. The Confinement Vessel Assay System (CVAS) was developed to measure the amount of SNM in CVs before and after cleanout. Prior to cleanout, the system will be used to perform a verification measurement of each vessel. After cleanout, the system will be used to perform safeguards-quality assays of (le) 100-g 239 Pu equivalent in a vessel for safeguards termination. The system was calibrated in three different mass regions (low, medium, and high) to cover the entire plutonium mass range that will be assayed. The low mass calibration and medium mass calibration were verified for material positioned in the center of an empty vessel. The systematic uncertainty due to position bias was estimated using an MCNPX model to simulate the response of the system to material localized at various points along the inner surface of the vessel. The background component due to cosmic ray spallation was determined by performing measurements of an empty vessel and comparing to measurements in the same location with no vessel present. The CVAS has been tested and calibrated in preparation for verification and safeguards measurements of CVs before and after cleanout.

  1. Method for temporary shielding of reactor vessel internals

    International Nuclear Information System (INIS)

    Grimm, N.P.; Sejvar, J.

    1991-01-01

    This patent describes a method for shielding stored internals for reactor vessel annealing. It comprises removing nuclear fuel from the reactor vessel containment building; removing and storing upper and lower core internals under water in a refueling canal storage area; assembling a support structure in the refueling canal between the reactor vessel and the stored internals; introducing vertical shielding tanks individually through a hatch in the containment building and positioning each into the support structure; introducing horizontal shielding tanks individually through a hatch in the containment building and positioning each above the stored internals and vertical tanks; draining water from the refueling canal to the level of a flange of the reactor vessel; placing an annealing apparatus in the reactor vessel; pumping the remaining water from the reactor vessel; and annealing the reactor vessel

  2. Method of burying vessel containing radioactive waste

    International Nuclear Information System (INIS)

    Koga, Yoshihito.

    1989-01-01

    A float having an inert gas sealed therein is attached to a tightly closed vessel containing radioactive wastes. The vessel is inserted and kept in a small hole for burying the tightly closed vessel in an excavated shaft in rocks such as of granite or rock salts, while filling bentonite as shielding material therearound. In this case, the float is so adjusted that the apparent specific gravity is made equal or nearer between the tightly closed vessel and the bentonite, so that the rightly closed vessel does not sink and cause direct contact with the rocks even if bentonite flows due to earthquakes, etc. This can prevent radioactivity contamination through water in the rocks. (S.K.)

  3. Life extension of the BR2 aluminium vessel

    International Nuclear Information System (INIS)

    Koonen, E.; Fabry, A.; Chaouadi, R.; Verwerft, M.; Raedt, C. de; Winckel, S. van; Wacquier, W.; Dadoumont, J.; Verwimp, A.

    2000-01-01

    The BR2 reactor has recently undergone a major refurbishment comprising the replacement of all vessel internals. The vessel itself however was not replaced. An important requalification programme has been executed to prove that the vessel would remain fit during the contemplated life extension period of BR2. Representative material samples could be obtained from the shroud surrounding the vessel. A comprehensive in-service inspection was carried out and a vessel surveillance programme has been established. (author)

  4. Asymptotics for the greatest zeros of solutions of a particular O.D.E.

    Directory of Open Access Journals (Sweden)

    Silvia Noschese

    1994-05-01

    Full Text Available This paper deals with the Liouville-Stekeloff method for approximating solutions of homogeneous linear ODE and a general result due to Tricomi which provides estimates for the zeros of functions by means of the knowledge of an asymptotic representation. From the classical tools we deduce information about the asymptotics of the greatest zeros of a class of solutions of a particular ODE, including the classical Hermite polynomials.

  5. Reactor pressure vessel status report

    International Nuclear Information System (INIS)

    Strosnider, J.; Wichman, K.; Elliot, B.

    1994-12-01

    This report gives a brief description of the reactor pressure vessel (RPV), followed by a discussion of the radiation embrittlement of RPV beltline materials and the two indicators for measuring embrittlement, the end-of-license (EOL) reference temperature and the EOL upper-shelf energy. It also summarizes the GL 92-01 effort and presents, for all 37 boiling water reactor plants and 74 pressurized water reactor plants in the United States, the current status of compliance with regulatory requirements related to ensuring RPV integrity. The staff has evaluated the material data needed to predict neutron embrittlement of the reactor vessel beltline materials. These data will be stored in a computer database entitled the reactor vessel integrity database (RVID). This database will be updated annually to reflect the changes made by the licensees in future submittals and will be used by the NRC staff to assess the issues related to vessel structural integrity

  6. Radioactive liquid containing vessel

    International Nuclear Information System (INIS)

    Sakurada, Tetsuo; Kawamura, Hironobu.

    1993-01-01

    Cooling jackets are coiled around the outer circumference of a container vessel, and the outer circumference thereof is covered with a surrounding plate. A liquid of good conductivity (for example, water) is filled between the cooling jackets and the surrounding plate. A radioactive liquid is supplied to the container vessel passing through a supply pipe and discharged passing through a discharge pipe. Cooling water at high pressure is passed through the cooling water jackets in order to remove the heat generated from the radioactive liquid. Since cooling water at high pressure is thus passed through the coiled pipes, the wall thickness of the container vessel and the cooling water jackets can be reduced, thereby enabling to reduce the cost. Further, even if the radioactive liquid is leaked, there is no worry of contaminating cooling water, to prevent contamination. (I.N.)

  7. The pressure vessel for the NSF tandem

    International Nuclear Information System (INIS)

    Jones, C.W.

    1979-04-01

    The pressure vessel is a major component of the 30 MV tandem Van de Graaff electrostatic accelerator to be used in nuclear structure research at Daresbury Laboratory. The accelerator will be capable of accelerating the full range of ions in the form of a beam. Acceleration takes place in a vertical evacuated tube (beam tube) by means of a high potential on a terminal at the central position, the terminal and beam tube assembly being supported by an insulated stack structure within the pressure vessel. Under operating conditions the vessel is filled with sulphur hexafluoride gas (SF 6 ) at high pressure which acts as an insulating medium between the centre terminal and the vessel wall. The vessel is situated inside a concrete tower which besides supporting the injector room above the vessel also acts as radiation shielding around the accelerator. The report covers: functional requirements; fundamental considerations with regard to the design and procurement; detail design; materials; manufacture; acceptance test; surface treatment; final leak test. (U.K.)

  8. Limiting Factors for External Reactor Vessel Cooling

    International Nuclear Information System (INIS)

    Cheung, F.B.

    2005-01-01

    The method of external reactor vessel cooling (ERVC) that involves flooding of the reactor cavity during a severe accident has been considered a viable means for in-vessel retention (IVR). For high-power reactors, however, there are some limiting factors that might adversely affect the feasibility of using ERVC as a means for IVR. In this paper, the key limiting factors for ERVC have been identified and critically discussed. These factors include the choking limit for steam venting (CLSV) through the bottleneck of the vessel/insulation structure, the critical heat flux (CHF) for downward-facing boiling on the vessel outer surface, and the two-phase flow instabilities in the natural circulation loop within the flooded cavity. To enhance ERVC, it is necessary to eliminate or relax these limiting factors. Accordingly, methods to enhance ERVC and thus improve margins for IVR have been proposed and demonstrated, using the APR1400 as an example. The strategy is based on using two distinctly different methods to enhance ERVC. One involves the use of an enhanced vessel/insulation design to facilitate steam venting through the bottleneck of the annular channel. The other involves the use of an appropriate vessel coating to promote downward-facing boiling. It is found that the use of an enhanced vessel/insulation design with bottleneck enlargement could greatly facilitate the process of steam venting through the bottleneck region as well as streamline the resulting two-phase motions in the annular channel. By selecting a suitable enhanced vessel/insulation design, not only the CLSV but also the CHF limits could be significantly increased. In addition, the problem associated with two-phase flow instabilities and flow-induced mechanical vibration could be minimized. It is also found that the use of vessel coatings made of microporous metallic layers could greatly facilitate downward-facing boiling on the vessel outer surface. With vessel coatings, the local CHF limits at

  9. Proactive life extension of pressure vessels

    Science.gov (United States)

    Mager, Lloyd

    1998-03-01

    For a company to maintain its competitive edge in today's global market every opportunity to gain an advantage must be exploited. Many companies are strategically focusing on improved utilization of existing equipment as well as regulatory compliance. Abbott Laboratories is no exception. Pharmaceutical companies such as Abbott Laboratories realize that reliability and availability of their production equipment is critical to be successful and competitive. Abbott Laboratories, like many of our competitors, is working to improve safety, minimize downtime and maximize the productivity and efficiency of key production equipment such as the pressure vessels utilized in our processes. The correct strategy in obtaining these objectives is to perform meaningful inspection with prioritization based on hazard analysis and risk. The inspection data gathered in Abbott Laboratories pressure vessel program allows informed decisions leading to improved process control. The results of the program are reduced risks to the corporation and employees when operating pressure retaining equipment. Accurate and meaningful inspection methods become the cornerstone of a program allowing proper preventative maintenance actions to occur. Successful preventative/predictive maintenance programs must utilize meaningful nondestructive evaluation techniques and inspection methods. Nondestructive examination methods require accurate useful tools that allow rapid inspection for the entire pressure vessel. Results from the examination must allow the owner to prove compliance of all applicable regulatory laws and codes. At Abbott Laboratories the use of advanced NDE techniques, primarily B-scan ultrasonics, has provided us with the proper tools allowing us to obtain our objectives. Abbott Laboratories uses B-scan ultrasonics utilizing a pulse echo pitch catch technique to provide essential data on our pressure vessels. Equipment downtime is reduced because the nondestructive examination usually takes

  10. Determinants of injuries in passenger vessel accidents.

    Science.gov (United States)

    Yip, Tsz Leung; Jin, Di; Talley, Wayne K

    2015-09-01

    This paper investigates determinants of crew and passenger injuries in passenger vessel accidents. Crew and passenger injury equations are estimated for ferry, ocean cruise, and river cruise vessel accidents, utilizing detailed data of individual vessel accidents that were investigated by the U.S. Coast Guard during the time period 2001-2008. The estimation results provide empirical evidence (for the first time in the literature) that crew injuries are determinants of passenger injuries in passenger vessel accidents. Copyright © 2015 Elsevier Ltd. All rights reserved.

  11. Improved nuclear reactor construction with bottom supported reactor vessel

    International Nuclear Information System (INIS)

    Sharbaugh, J.E.

    1987-01-01

    An improved liquid metal nuclear reactor construction has a reactor core and a generally cylindrical reactor vessel for holding liquid metal coolant and housing the core within the pool. A generally cylindrical concrete containment structure surrounds the reactor vessel and a central support pedestal is anchored to the containment structure base mat and supports the bottom wall of the reactor vessel and the reactor core. The periphery of the reactor vessel bore is supported by an annular structure which allows thermal expansion but not seismic motion of the vessel, and a bed of thermally insulating material uniformly supports the vessel base whilst allowing expansion thereof. A guard ring prevents lateral seismic motion of the upper end of the reactor vessel. The periphery of the core is supported by an annular structure supported by the vessel base and keyed to the vessel wall so as to be able to expand but not undergo seismic motion. A deck is supported on the containment structure above the reactor vessel open top by annular bellows, the deck carrying the reactor control rods such that heating of the reactor vessel results in upward expansion against the control rods. (author)

  12. Final processing vessel for radioactive waste

    International Nuclear Information System (INIS)

    Tejima, Takaya; Hiraki, Akimitsu.

    1989-01-01

    An inorganic inner layer comprising dense inorganic material such as organic polymer-impregnated concretes is formed to about 10 - 50 mm in average thickness at the inside of a metal vessel. Further, the surface of the vessel is formed as a flat surface with no or only small reinforcing protrusions. Thus, if the final processing vessel should be dropped during transportation or handling by mistake, since impact shocks do not concentrate to protrusions as usual, no local stress concentration occurs to the inorganic inner liner layer. Accordingly, the risk of rapture can be reduced greatly. Further, since impact shock resistance layer put between the metal vessel and the inorganic inner liner layer absorbs shocks, a further sufficient strength can be obtained against dropping accident. (T.M.)

  13. 33 CFR 88.11 - Law enforcement vessels.

    Science.gov (United States)

    2010-07-01

    ... NAVIGATION RULES ANNEX V: PILOT RULES § 88.11 Law enforcement vessels. (a) Law enforcement vessels may display a flashing blue light when engaged in direct law enforcement or public safety activities. This... lights. (b) The blue light described in this section may be displayed by law enforcement vessels of the...

  14. 2013 EPA Vessels General Permit (VGP)

    Data.gov (United States)

    U.S. Environmental Protection Agency — Information for any vessel that submitted a Notice of Intent (NOI), Notice of Termination (NOT), or annual report under EPA's 2013 Vessel General Permit (VGP)....

  15. Relative accuracy of the BD Logic and FreeStyle blood glucose meters.

    Science.gov (United States)

    2007-04-01

    The BD Logic((R)) (Becton, Dickinson and Co., Franklin Lakes, NJ) and FreeStyle((R)) (Abbott Diabetes Care, Alameda, CA) meters are used to transmit data directly to insulin pumps for calculation of insulin doses and to calibrate continuous glucose sensors as well as to monitor blood glucose levels. The accuracy of the two meters was evaluated in two inpatient studies conducted by the Diabetes Research in Children Network (DirecNet). In both studies, meter glucose measurements made with either venous or capillary blood were compared with reference glucose measurements made by the DirecNet Central Laboratory at the University of Minnesota using a hexokinase enzymatic method. The BD Logic tended to read lower than the laboratory reference regardless of whether venous (median difference = -9 mg/dL) or capillary blood (median difference = -7 mg/dL) was used. This resulted in lower accuracy of the BD Logic compared with the FreeStyle meter based on the median relative absolute difference (RAD) for both venous blood (median RAD, 9% vs. 5%, P blood (median RAD, 11% vs. 6%, P = 0.008). The greatest discrepancy in the performance of the two meters was at higher reference glucose values. Accuracy was not significantly different when the reference was < or = 70 mg/dL. The BD Logic meter is less accurate than the FreeStyle meter.

  16. EDS V25 containment vessel explosive qualification test report.

    Energy Technology Data Exchange (ETDEWEB)

    Rudolphi, John Joseph

    2012-04-01

    The V25 containment vessel was procured by the Project Manager, Non-Stockpile Chemical Materiel (PMNSCM) as a replacement vessel for use on the P2 Explosive Destruction Systems. It is the first EDS vessel to be fabricated under Code Case 2564 of the ASME Boiler and Pressure Vessel Code, which provides rules for the design of impulsively loaded vessels. The explosive rating for the vessel based on the Code Case is nine (9) pounds TNT-equivalent for up to 637 detonations. This limit is an increase from the 4.8 pounds TNT-equivalency rating for previous vessels. This report describes the explosive qualification tests that were performed in the vessel as part of the process for qualifying the vessel for explosive use. The tests consisted of a 11.25 pound TNT equivalent bare charge detonation followed by a 9 pound TNT equivalent detonation.

  17. Guidelines for pressure vessel safety assessment

    Science.gov (United States)

    Yukawa, S.

    1990-04-01

    A technical overview and information on metallic pressure containment vessels and tanks is given. The intent is to provide Occupational Safety and Health Administration (OSHA) personnel and other persons with information to assist in the evaluation of the safety of operating pressure vessels and low pressure storage tanks. The scope is limited to general industrial application vessels and tanks constructed of carbon or low alloy steels and used at temperatures between -75 and 315 C (-100 and 600 F). Information on design codes, materials, fabrication processes, inspection and testing applicable to the vessels and tanks are presented. The majority of the vessels and tanks are made to the rules and requirements of ASME Code Section VIII or API Standard 620. The causes of deterioration and damage in operation are described and methods and capabilities of detecting serious damage and cracking are discussed. Guidelines and recommendations formulated by various groups to inspect for the damages being found and to mitigate the causes and effects of the problems are presented.

  18. Model tests for prestressed concrete pressure vessels

    International Nuclear Information System (INIS)

    Stoever, R.

    1975-01-01

    Investigations with models of reactor pressure vessels are used to check results of three dimensional calculation methods and to predict the behaviour of the prototype. Model tests with 1:50 elastic pressure vessel models and with a 1:5 prestressed concrete pressure vessel are described and experimental results are presented. (orig.) [de

  19. Sealing method and sealing device for radioactive waste containing vessel

    International Nuclear Information System (INIS)

    Ishiwatari, Koji; Otsuki, Akira

    1998-01-01

    A radioactive waste-containing body is hoisted down into a strong-material vessel opened upwardly, and a strong-material lid is hoisted down to the opening of the strong-material-vessel and welded. The strong material vessel is hoisted up and loaded on a corrosion resistant-material bottom plate placed horizontally. A corrosion resistant-material vessel having one opening end and having a corrosion resistant-material flange on the other end and previously agreed with the strong material-vessel main body is hoisted up by a hoisting device having an inserting device so that the opening of the corrosion resistant vessel is directed downwardly. The corrosion resistant vessel is press-fitted to the outside of the strong material-vessel by the inserting device while being heated by a preheater to shrink. Subsequently, the lower end of the corrosion resistant-material vessel and the corrosion resistant-material bottom plate are welded to constitute a corrosion resistant-material vessel. Then, the radioactive waste containing body can be sealed in a sealing vessel comprising the strong-material vessel and the corrosion resistant-material vessel. (N.H.)

  20. Bone marrow blood vessels: normal and neoplastic niche

    Directory of Open Access Journals (Sweden)

    Saeid Shahrabi

    2016-11-01

    Full Text Available Blood vessels are among the most important factors in the transport of materials such as nutrients and oxygen. This study will review the role of blood vessels in normal bone marrow hematopoiesis as well as pathological conditions like leukemia and metastasis. Relevant literature was identified by a Pubmed search (1992-2016 of English-language papers using the terms bone marrow, leukemia, metastasis, and vessel. Given that blood vessels are conduits for the transfer of nutrients, they create a favorable situation for cancer cells and cause their growth and development. On the other hand, blood vessels protect leukemia cells against chemotherapy drugs. Finally, it may be concluded that the vessels are an important factor in the development of malignant diseases.

  1. Expression of the growth factor progranulin in endothelial cells influences growth and development of blood vessels: a novel mouse model.

    Science.gov (United States)

    Toh, Huishi; Cao, Mingju; Daniels, Eugene; Bateman, Andrew

    2013-01-01

    Progranulin is a secreted glycoprotein that regulates cell proliferation, migration and survival. It has roles in development, tumorigenesis, wound healing, neurodegeneration and inflammation. Endothelia in tumors, wounds and placenta express elevated levels of progranulin. In culture, progranulin activates endothelial proliferation and migration. This suggested that progranulin might regulate angiogenesis. It was, however, unclear how elevated endothelial progranulin levels influence vascular growth in vivo. To address this issue, we generated mice with progranulin expression targeted specifically to developing endothelial cells using a Tie2-promoter/enhancer construct. Three Tie2-Grn mouse lines were generated with varying Tie2-Grn copy number, and were called GrnLo, GrnMid, and GrnHi. All three lines showed increased mortality that correlates with Tie2-Grn copy number, with greatest mortality and lowest germline transmission in the GrnHi line. Death of the transgenic animals occurred around birth, and continued for three days after birth. Those that survived beyond day 3 survived into adulthood. Transgenic neonates that died showed vascular abnormalities of varying severity. Some exhibited bleeding into body cavities such as the pericardial space. Smaller localized hemorrhages were seen in many organs. Blood vessels were often dilated and thin-walled. To establish the development of these abnormalities, we examined mice at early (E10.5-14.5) and later (E15.5-17.5) developmental phases. Early events during vasculogenesis appear unaffected by Tie2-Grn as apparently normal primary vasculature had been established at E10.5. The earliest onset of vascular abnormality was at E15.5, with focal cerebral hemorrhage and enlarged vessels in various organs. Aberrant Tie2-Grn positive vessels showed thinning of the basement membrane and reduced investiture with mural cells. We conclude that progranulin promotes exaggerated vessel growth in vivo, with subsequent effects in

  2. Expression of the growth factor progranulin in endothelial cells influences growth and development of blood vessels: a novel mouse model.

    Directory of Open Access Journals (Sweden)

    Huishi Toh

    Full Text Available Progranulin is a secreted glycoprotein that regulates cell proliferation, migration and survival. It has roles in development, tumorigenesis, wound healing, neurodegeneration and inflammation. Endothelia in tumors, wounds and placenta express elevated levels of progranulin. In culture, progranulin activates endothelial proliferation and migration. This suggested that progranulin might regulate angiogenesis. It was, however, unclear how elevated endothelial progranulin levels influence vascular growth in vivo. To address this issue, we generated mice with progranulin expression targeted specifically to developing endothelial cells using a Tie2-promoter/enhancer construct. Three Tie2-Grn mouse lines were generated with varying Tie2-Grn copy number, and were called GrnLo, GrnMid, and GrnHi. All three lines showed increased mortality that correlates with Tie2-Grn copy number, with greatest mortality and lowest germline transmission in the GrnHi line. Death of the transgenic animals occurred around birth, and continued for three days after birth. Those that survived beyond day 3 survived into adulthood. Transgenic neonates that died showed vascular abnormalities of varying severity. Some exhibited bleeding into body cavities such as the pericardial space. Smaller localized hemorrhages were seen in many organs. Blood vessels were often dilated and thin-walled. To establish the development of these abnormalities, we examined mice at early (E10.5-14.5 and later (E15.5-17.5 developmental phases. Early events during vasculogenesis appear unaffected by Tie2-Grn as apparently normal primary vasculature had been established at E10.5. The earliest onset of vascular abnormality was at E15.5, with focal cerebral hemorrhage and enlarged vessels in various organs. Aberrant Tie2-Grn positive vessels showed thinning of the basement membrane and reduced investiture with mural cells. We conclude that progranulin promotes exaggerated vessel growth in vivo, with

  3. Vessel calibration for accurate material accountancy at RRP

    International Nuclear Information System (INIS)

    Yanagisawa, Yuu; Ono, Sawako; Iwamoto, Tomonori

    2004-01-01

    RRP has a 800t·Upr capacity a year to re-process, where would be handled a large amount of nuclear materials as solution. A large scale plant like RRP will require accurate materials accountancy system, so that the vessel calibration with high-precision is very important as initial vessel calibration before operation. In order to obtain the calibration curve, it is needed well-known each the increment volume related with liquid height. Then we performed at least 2 or 3 times run with water for vessel calibration and careful evaluation for the calibration data should be needed. We performed vessel calibration overall 210 vessels, and the calibration of 81 vessels including IAT and OAT were held under presence of JSGO and IAEA inspectors taking into account importance on the material accountancy. This paper describes outline of the initial vessel calibration and calibration results based on back pressure measurement with dip tubes. (author)

  4. 46 CFR 90.10-16 - Industrial vessel.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 4 2010-10-01 2010-10-01 false Industrial vessel. 90.10-16 Section 90.10-16 Shipping... PROVISIONS Definition of Terms Used in This Subchapter § 90.10-16 Industrial vessel. This term means every vessel which by reason of its special outfit, purpose, design, or function engages in certain industrial...

  5. Equipment for decontamination of inner vessel surfaces featuring sound or ultrasound transducer on float inside liquid-filled vessel

    International Nuclear Information System (INIS)

    Bar, J.; Straka, M.

    1982-01-01

    The equipment for the decontamination of the inner surfaces of vessels consists of an immersion float which is provided with a screw, an electric motor, a rudder and at least one float chamber, and a remotely controlled valve. The float is provided with a power source, a high frequency a.c. current generator and a control panel outside the vessel. The float is connected to parts of the equipment outside the vessel by a multi-core cable. The immersion float may also be provided with a detector for measuring the quantity of ionizing radiation whose display is placed outside the vessel being decontaminated. (B.S.)

  6. Discharge of Non-Reactive Fluids from Vessels

    Directory of Open Access Journals (Sweden)

    M. Castier

    Full Text Available Abstract This paper presents simulations of discharges from pressure vessels that consistently account for non-ideal fluid behavior in all the required thermodynamic properties and individually considers all the chemical components present. The underlying assumption is that phase equilibrium occurs instantaneously inside the vessel and, thus, the dynamics of the fluid in the vessel comprises a sequence of equilibrium states. The formulation leads to a system of differential-algebraic equations in which the component mass balances and the energy balance are ordinary differential equations. The algebraic equations account for the phase equilibrium conditions inside the vessel and at the discharge point, and for sound speed calculations. The simulator allows detailed predictions of the condition inside the vessel and at the discharge point as a function of time, including the flow rate and composition of the discharge. The paper presents conceptual applications of the simulator to predict the effect of leaks from vessels containing mixtures of light gases and/or hydrocarbons and comparisons to experimental data.

  7. Pressure vessel integrity and weld inspection procedure

    International Nuclear Information System (INIS)

    Solomon, K.A.; Okrent, D.; Kastenberg, W.E.

    1975-01-01

    The primary objective of this paper is to develop a simple methodology which, when coupled with existing observations on pressure vessel behavior, provides an inter-relation between pressure vessel integrity, and the parameters of the in-service inspection program, including inspection sample size, frequency and efficiency. A modified Markov process is employed and a computer code was written to obtain numerical results. The Markov process mathematically describes the following physical events. In a nuclear reactor pressure vessel weld, some defects may exist prior to the zeroth inspection (i.e., prior to vessel operation). During the zeroth inspection and repair processes, some of these defects are removed. During the first cycle of vessel operation, the existing defects may grow and some new defects may be generated. Those defects that are found at the first (and succeeding) inspection interval and warrant repair, are repaired. The above process continues through several operating cycles to the end of vessel life. During any inspection, only a portion of the welds may be inspected, and with less than perfect efficiency

  8. Nuclear power plant pressure vessels. Control of piping

    International Nuclear Information System (INIS)

    2000-01-01

    The guide presents requirements for the pipework of nuclear facilities in Finland. According to the section 117 of the Finnish Nuclear Energy Degree (161/88), the Radiation and Nuclear Safety Authority of Finland (STUK) controls the pressure vessels of nuclear facilities in accordance with the Nuclear Energy Act (990/87) and, to the extent applicable in accordance with the Act of Pressure Vessels (98/73) and the rules and regulations issued by the virtue of these. In addition STUK is an inspecting authority of pressure vessels of nuclear facilities in accordance with the Pressure Vessel Degree (549/1973). According to the section of the Pressure Vessel Degree, a pressure vessel is a steam boiler, pressure container, pipework of other such appliance in which the pressure is above or may come to exceed the atmospheric pressure. Guide YVL 3.0 describes in general terms how STUK controls pressure vessels. STUK controls Safety Class 1, 2 and 3 piping as well as Class EYT (non-nuclear) and their support structures in accordance with this guide and applies the provisions of the Decision of the Ministry of Trade and Industry on piping (71/1975) issued by virtue of the Pressure Vessel Decree

  9. Fast-neutron nuclear reactor vessel

    International Nuclear Information System (INIS)

    Presciuttini, L.

    1984-01-01

    The reactor vessel comprises a cylindrical shell, of which axis is vertical, coupled at its lower part with a dished bottom. The reactor core rests on a support plate bearing on the bottom of the vessel. The above dished bottom comprises a spherical sector having the same radius and the same axis as the cylindrical shell and joining the lower part of the shell, and a spherical head of which radius is a little more important than the spherical sector one. A cylindrical support for the reactor core is attached to the vessel at the joint between the two dished sections. The invention applies more particularly to integrated type reactors cooled by liquid sodium [fr

  10. Influence of Spatial Resolution in Three-dimensional Cine Phase Contrast Magnetic Resonance Imaging on the Accuracy of Hemodynamic Analysis.

    Science.gov (United States)

    Fukuyama, Atsushi; Isoda, Haruo; Morita, Kento; Mori, Marika; Watanabe, Tomoya; Ishiguro, Kenta; Komori, Yoshiaki; Kosugi, Takafumi

    2017-10-10

    We aim to elucidate the effect of spatial resolution of three-dimensional cine phase contrast magnetic resonance (3D cine PC MR) imaging on the accuracy of the blood flow analysis, and examine the optimal setting for spatial resolution using flow phantoms. The flow phantom has five types of acrylic pipes that represent human blood vessels (inner diameters: 15, 12, 9, 6, and 3 mm). The pipes were fixed with 1% agarose containing 0.025 mol/L gadolinium contrast agent. A blood-mimicking fluid with human blood property values was circulated through the pipes at a steady flow. Magnetic resonance (MR) images (three-directional phase images with speed information and magnitude images for information of shape) were acquired using the 3-Tesla MR system and receiving coil. Temporal changes in spatially-averaged velocity and maximum velocity were calculated using hemodynamic analysis software. We calculated the error rates of the flow velocities based on the volume flow rates measured with a flowmeter and examined measurement accuracy. When the acrylic pipe was the size of the thoracicoabdominal or cervical artery and the ratio of pixel size for the pipe was set at 30% or lower, spatially-averaged velocity measurements were highly accurate. When the pixel size ratio was set at 10% or lower, maximum velocity could be measured with high accuracy. It was difficult to accurately measure maximum velocity of the 3-mm pipe, which was the size of an intracranial major artery, but the error for spatially-averaged velocity was 20% or less. Flow velocity measurement accuracy of 3D cine PC MR imaging for pipes with inner sizes equivalent to vessels in the cervical and thoracicoabdominal arteries is good. The flow velocity accuracy for the pipe with a 3-mm-diameter that is equivalent to major intracranial arteries is poor for maximum velocity, but it is relatively good for spatially-averaged velocity.

  11. Accuracy of magnetic resonance based susceptibility measurements

    Science.gov (United States)

    Erdevig, Hannah E.; Russek, Stephen E.; Carnicka, Slavka; Stupic, Karl F.; Keenan, Kathryn E.

    2017-05-01

    Magnetic Resonance Imaging (MRI) is increasingly used to map the magnetic susceptibility of tissue to identify cerebral microbleeds associated with traumatic brain injury and pathological iron deposits associated with neurodegenerative diseases such as Parkinson's and Alzheimer's disease. Accurate measurements of susceptibility are important for determining oxygen and iron content in blood vessels and brain tissue for use in noninvasive clinical diagnosis and treatment assessments. Induced magnetic fields with amplitude on the order of 100 nT, can be detected using MRI phase images. The induced field distributions can then be inverted to obtain quantitative susceptibility maps. The focus of this research was to determine the accuracy of MRI-based susceptibility measurements using simple phantom geometries and to compare the susceptibility measurements with magnetometry measurements where SI-traceable standards are available. The susceptibilities of paramagnetic salt solutions in cylindrical containers were measured as a function of orientation relative to the static MRI field. The observed induced fields as a function of orientation of the cylinder were in good agreement with simple models. The MRI susceptibility measurements were compared with SQUID magnetometry using NIST-traceable standards. MRI can accurately measure relative magnetic susceptibilities while SQUID magnetometry measures absolute magnetic susceptibility. Given the accuracy of moment measurements of tissue mimicking samples, and the need to look at small differences in tissue properties, the use of existing NIST standard reference materials to calibrate MRI reference structures is problematic and better reference materials are required.

  12. Diagnostic accuracy of high-definition CT coronary angiography in high-risk patients

    International Nuclear Information System (INIS)

    Iyengar, S.S.; Morgan-Hughes, G.; Ukoumunne, O.; Clayton, B.; Davies, E.J.; Nikolaou, V.; Hyde, C.J.; Shore, A.C.; Roobottom, C.A.

    2016-01-01

    Aim: To assess the diagnostic accuracy of computed tomography coronary angiography (CTCA) using a combination of high-definition CT (HD-CTCA) and high level of reader experience, with invasive coronary angiography (ICA) as the reference standard, in high-risk patients for the investigation of coronary artery disease (CAD). Materials and methods: Three hundred high-risk patients underwent HD-CTCA and ICA. Independent experts evaluated the images for the presence of significant CAD, defined primarily as the presence of moderate (≥50%) stenosis and secondarily as the presence of severe (≥70%) stenosis in at least one coronary segment, in a blinded fashion. HD-CTCA was compared to ICA as the reference standard. Results: No patients were excluded. Two hundred and six patients (69%) had moderate and 178 (59%) had severe stenosis in at least one vessel at ICA. The sensitivity, specificity, positive predictive value, and negative predictive value were 97.1%, 97.9%, 99% and 93.9% for moderate stenosis, and 98.9%, 93.4%, 95.7% and 98.3%, for severe stenosis, on a per-patient basis. Conclusion: The combination of HD-CTCA and experienced readers applied to a high-risk population, results in high diagnostic accuracy comparable to ICA. Modern generation CT systems in experienced hands might be considered for an expanded role. - Highlights: • Diagnostic accuracy of High-Definition CT Angiography (HD-CTCA) has been assessed. • Invasive Coronary angiography (ICA) is the reference standard. • Diagnostic accuracy of HD-CTCA is comparable to ICA. • Diagnostic accuracy is not affected by coronary calcium or stents. • HD-CTCA provides a non-invasive alternative in high-risk patients.

  13. Application of annealing for WWER vessels life extension

    International Nuclear Information System (INIS)

    Badanin, V.I.; Gorynin, I.V.; Nickolaev, V.A.; Dragunov, Y.G.; Fedorov, V.G.

    1989-01-01

    Safe operation of NPP is greatly dependent on the guarantee of reactor vessel brittle failure strength with account for the effect of radiation embrittlement of vessel material. Recovery of irradiated material properties is principally important way to extend radiation life of reactor vessel. The aim of this report is to demonstrate the efficiency of annealing for recovery of vessel material properties and extension of its service-life

  14. Proof testing of an explosion containment vessel

    Energy Technology Data Exchange (ETDEWEB)

    Esparza, E.D. [Esparza (Edward D.), San Antonio, TX (United States); Stacy, H.; Wackerle, J. [Los Alamos National Lab., NM (United States)

    1996-10-01

    A steel containment vessel was fabricated and proof tested for use by the Los Alamos National Laboratory at their M-9 facility. The HY-100 steel vessel was designed to provide total containment for high explosives tests up to 22 lb (10 kg) of TNT equivalent. The vessel was fabricated from an 11.5-ft diameter cylindrical shell, 1.5 in thick, and 2:1 elliptical ends, 2 in thick. Prior to delivery and acceptance, three types of tests were required for proof testing the vessel: a hydrostatic pressure test, air leak tests, and two full design charge explosion tests. The hydrostatic pressure test provided an initial static check on the capacity of the vessel and functioning of the strain instrumentation. The pneumatic air leak tests were performed before, in between, and after the explosion tests. After three smaller preliminary charge tests, the full design charge weight explosion tests demonstrated that no yielding occurred in the vessel at its rated capacity. The blast pressures generated by the explosions and the dynamic response of the vessel were measured and recorded with 33 strain channels, 4 blast pressure channels, 2 gas pressure channels, and 3 displacement channels. This paper presents an overview of the test program, a short summary of the methodology used to predict the design blast loads, a brief description of the transducer locations and measurement systems, some of the hydrostatic test strain and stress results, examples of the explosion pressure and dynamic strain data, and some comparisons of the measured data with the design loads and stresses on the vessel.

  15. Diagnosis of moyamoya disease using 3-T MRI and MRA: value of cisternal moyamoya vessels

    Energy Technology Data Exchange (ETDEWEB)

    Sawada, Takeshi; Yamamoto, Akira; Okada, Tomohisa; Kanagaki, Mitsunori; Kasahara, Seiko; Togashi, Kaori [Kyoto University, Department of Diagnostic Imaging and Nuclear Medicine, Graduate School of Medicine, Kyoto (Japan); Miki, Yukio [Osaka City University, Department of Radiology, Graduate School of Medicine, Osaka (Japan); Kikuta, Ken-ichiro [Fukui University, Division of Neurosurgery, Department of Sensory and Locomotor Medicine, Faculty of Medical Sciences, Fukui (Japan); Miyamoto, Susumu; Takahashi, Jun C. [Kyoto University, Department of Neurosurgery, Graduate School of Medicine, Kyoto (Japan); Fukuyama, Hidenao [Kyoto University, Human Brain Research Center, Graduate School of Medicine, Kyoto (Japan)

    2012-10-15

    The purpose of this study was to propose new magnetic resonance (MR) criteria of diagnosing moyamoya disease (MMD) from cisternal moyamoya vessels (MMVs) on 3-T magnetic resonance imaging (MRI)/magnetic resonance angiography (MRA) and compare the diagnostic accuracy of the existing MR criteria and the proposed MR criteria. Participants comprised 20 consecutive patients with MMD (4 males, 16 females) diagnosed clinically using conventional angiography and 20 controls (13 male and 7 female arteriosclerosis patients). In these participants, 3-T MRI/MRA was evaluated by the existing MR criteria, which use MMVs in the basal ganglia, and the proposed MR criteria, which use cisternal MMVs, and then these two criteria were statistically compared by McNemar's test. Diagnostic accuracy was 62.5% with the existing MR criteria and 97.5% with the proposed MR criteria. The proposed MR criteria was more sensitive (1.00) than the existing MR criteria (0.45), but less specific (0.95) than the existing MR criteria (1.00). The proposed MR criteria using cisternal MMVs showed significantly higher diagnostic accuracy than the existing MR criteria. We believe that our proposed MR criteria will be beneficial for diagnosing MMD. (orig.)

  16. Diagnosis of moyamoya disease using 3-T MRI and MRA: value of cisternal moyamoya vessels

    International Nuclear Information System (INIS)

    Sawada, Takeshi; Yamamoto, Akira; Okada, Tomohisa; Kanagaki, Mitsunori; Kasahara, Seiko; Togashi, Kaori; Miki, Yukio; Kikuta, Ken-ichiro; Miyamoto, Susumu; Takahashi, Jun C.; Fukuyama, Hidenao

    2012-01-01

    The purpose of this study was to propose new magnetic resonance (MR) criteria of diagnosing moyamoya disease (MMD) from cisternal moyamoya vessels (MMVs) on 3-T magnetic resonance imaging (MRI)/magnetic resonance angiography (MRA) and compare the diagnostic accuracy of the existing MR criteria and the proposed MR criteria. Participants comprised 20 consecutive patients with MMD (4 males, 16 females) diagnosed clinically using conventional angiography and 20 controls (13 male and 7 female arteriosclerosis patients). In these participants, 3-T MRI/MRA was evaluated by the existing MR criteria, which use MMVs in the basal ganglia, and the proposed MR criteria, which use cisternal MMVs, and then these two criteria were statistically compared by McNemar's test. Diagnostic accuracy was 62.5% with the existing MR criteria and 97.5% with the proposed MR criteria. The proposed MR criteria was more sensitive (1.00) than the existing MR criteria (0.45), but less specific (0.95) than the existing MR criteria (1.00). The proposed MR criteria using cisternal MMVs showed significantly higher diagnostic accuracy than the existing MR criteria. We believe that our proposed MR criteria will be beneficial for diagnosing MMD. (orig.)

  17. Reactor pressure vessel design

    International Nuclear Information System (INIS)

    Foehl, J.

    1998-01-01

    As a result of the popularity of the Agencies report 'Neutron Irradiation Embrittlement of Reactor Pressure Vessel Steels' of 1975, it was decided that another report on this broad subject would be of use. In this report, background and contemporary views on specially identified areas of the subject are considered as self-contained chapters, written by experts. In chapter 2, the general principles of reactor pressure vessel design are elaborated. Crack and fracture initiation and propagation are treated in some detail

  18. Prestressed reactor vessel for nuclear power plants

    International Nuclear Information System (INIS)

    Schoening, J.; Schwiers, H.G.

    1982-01-01

    With usual pressure vessels for nuclear reactor plants, especially for gas-cooled nuclear reactors, the load occurring due to the inner overpressure, especially the tensile load affecting the vessel top and/or bottom, their axis of inertia being horizontal, shall be compensated without a supplementary modification in design of the top and/or the bottom. This is attained by choosing an appropriate prestressing system of the vessel wall in the field the top and/or the bottom, so that the top and/or the bottom form a tension vault directed towards the interior of the vessel. (orig.) [de

  19. Increase of cyclic durability of pressure vessels

    International Nuclear Information System (INIS)

    Vorona, V.A.; Zvezdin, Yu.I.

    1980-01-01

    The durability of multilayer pressure vessels under cyclic loading is compared with single-layer vessels. The relative conditional durability is calculated taking into account the assumption on the consequent destruction of layers and viewing a vessel wall as an indefinite plate. It is established that the durability is mainly determined by the number of layers and to a lesser degree depends on the relative size of the defect for the given layer thickness. The advantage of the multilayer vessels is the possibility of selecting layer materials so that to exclude the effect of agressive corrosion media on the strength [ru

  20. Effect of vessel voyage speed on survival of biofouling organisms: implications for translocation of non-indigenous marine species.

    Science.gov (United States)

    Coutts, Ashley D M; Piola, Richard F; Hewitt, Chad L; Connell, Sean D; Gardner, Jonathan P A

    2010-01-01

    This study experimentally determined the effect of different vessel voyage speeds (5, 10 and 18 knots = 2.6, 5.1 and 9.3 ms(-1), respectively) and morphological characteristics including growth form (solitary or colonial), profile (erect or encrusting) and structure (soft, hard or flexible) on the survival of a range of common biofouling organisms. A custom built hydrodynamic keel attached to the bottom of a 6 m aluminium powerboat was used to subject pre-fouled settlement plates for this purpose. Vessel speeds of 5 and 10 knots had little effect on the species richness of biofouling assemblages tested, however richness decreased by 50% following 18 knots treatments. Species percentage cover decreased with increasing speed across all speed treatments and this decrease was most pronounced at 10 and 18 knots, with cover reduced by 24 and 85% respectively. Survival was greatest for organisms with colonial, encrusting, hard and/or flexible morphological characteristics, and this effect increased with increasing speed. This study suggests that there is predictive power in forecasting future introductions if we can understand the extent to which such traits explain the world-wide distributions of non-indigenous species. Future introductions are a certainty and can only provide an increasing source of new information on which to test the validity of these predications.

  1. Usefulness of Cone-Beam Computed Tomography and Automatic Vessel Detection Software in Emergency Transarterial Embolization

    Energy Technology Data Exchange (ETDEWEB)

    Carrafiello, Gianpaolo, E-mail: gcarraf@gmail.com; Ierardi, Anna Maria, E-mail: amierardi@yahoo.it; Duka, Ejona, E-mail: ejonaduka@hotmail.com [Insubria University, Department of Radiology, Interventional Radiology (Italy); Radaelli, Alessandro, E-mail: alessandro.radaelli@philips.com [Philips Healthcare (Netherlands); Floridi, Chiara, E-mail: chiara.floridi@gmail.com [Insubria University, Department of Radiology, Interventional Radiology (Italy); Bacuzzi, Alessandro, E-mail: alessandro.bacuzzi@ospedale.varese.it [University of Insubria, Anaesthesia and Palliative Care (Italy); Bucourt, Maximilian de, E-mail: maximilian.de-bucourt@charite.de [Charité - University Medicine Berlin, Department of Radiology (Germany); Marchi, Giuseppe De, E-mail: giuseppedemarchi@email.it [Insubria University, Department of Radiology, Interventional Radiology (Italy)

    2016-04-15

    BackgroundThis study was designed to evaluate the utility of dual phase cone beam computed tomography (DP-CBCT) and automatic vessel detection (AVD) software to guide transarterial embolization (TAE) of angiographically challenging arterial bleedings in emergency settings.MethodsTwenty patients with an arterial bleeding at computed tomography angiography and an inconclusive identification of the bleeding vessel at the initial 2D angiographic series were included. Accuracy of DP-CBCT and AVD software were defined as the ability to detect the bleeding site and the culprit arterial bleeder, respectively. Technical success was defined as the correct positioning of the microcatheter using AVD software. Clinical success was defined as the successful embolization. Total volume of iodinated contrast medium and overall procedure time were registered.ResultsThe bleeding site was not detected by initial angiogram in 20 % of cases, while impossibility to identify the bleeding vessel was the reason for inclusion in the remaining cases. The bleeding site was detected by DP-CBCT in 19 of 20 (95 %) patients; in one case CBCT-CT fusion was required. AVD software identified the culprit arterial branch in 18 of 20 (90 %) cases. In two cases, vessel tracking required manual marking of the candidate arterial bleeder. Technical success was 95 %. Successful embolization was achieved in all patients. Mean contrast volume injected for each patient was 77.5 ml, and mean overall procedural time was 50 min.ConclusionsC-arm CBCT and AVD software during TAE of angiographically challenging arterial bleedings is feasible and may facilitate successful embolization. Staff training in CBCT imaging and software manipulation is necessary.

  2. Reactor-vessel-sectioning demonstration

    International Nuclear Information System (INIS)

    Lundgren, R.A.

    1981-09-01

    A technical demonstration was successfully completed of simulated reactor vessel sectioning using the combined techniques of air arc gouging and flame cutting. A 4-ft x 3-ft x 9-in. thick sample was fabricated of A36 carbon steel to simulate a reactor vessel wall. A 1/4-in. layer of stainless steel (SS) was tungsten inert gas (TIG)-welded to the carbon steel. Several techniques were considered to section the simulated reactor vessel; air arc gouging was selected to penetrate the stainless steel, and flame cutting was selected to sever the carbon steel. Three sectioning operations were demonstrated. For all three, the operating parameters were the same; but the position of the sample was varied. For the first cut, the sample was placed in a horizontal position, and it was successfully severed from the SS side. For the second cut, the sample was turned over and cut from the carbon steel side. Cutting from the carbon steel side has the advantages of cost reduction

  3. Baking results of KSTAR vacuum vessel

    International Nuclear Information System (INIS)

    Kim, S. T.; Kim, Y. J.; Kim, K. M.; Im, D. S.; Joung, N. Y.; Yang, H. L.; Kim, Y. S.; Kwon, M.

    2009-01-01

    The Korea Superconducting Tokamak Advanced Research (KSTAR) is an advanced superconducting tokamak designed to establish a scientific and technological basis for an attractive fusion reactor. The fusion energy in the tokamak device is released through fusion reactions of light atoms such as deuterium or helium in hot plasma state, of which temperature reaches several hundreds of millions Celsius. The high temperature plasma is created in the vacuum vessel that provides ultra high vacuum status. Accordingly, it is most important for the vacuum condition to keep clean not only inner space but also surface of the vacuum vessel to make high quality plasma. There are two methods planned to clean the wall surface of the KSTAR vacuum vessel. One is surface baking and the other is glow discharge cleaning (GDC). To bake the vacuum vessel, De-Ionized (DI) water is heated to 130 .deg. C and circulated in the passage between double walls of the vacuum vessel (VV) in order to bake the surface. The GDC operation uses hydrogen and inert gas discharges. In this paper, general configuration and brief introduction of the baking result will be reported

  4. Reactor vessel supported by flexure member

    International Nuclear Information System (INIS)

    Crawford, J.D.; Pankow, B.

    1977-01-01

    According to the present invention there is provided an improved arrangement for supporting a reactor vessel within a containment structure against static and dynamic vertical loadings capable of being imposed as a result of a serious accident as well as during periods of normal plant operation. The support arrangement of the invention is, at the same time, capable of accommodating radial displacements that normally occur between the reactor vessel and the containment structure due to operational transients. The arrangement comprises a plurality of vertical columns connected between the reactor vessel and a support base within the containment structure. The columns are designed to accommodate relative displacements between the vessel and the containment structure by flexing. This eliminates the need for relative sliding movements and thus enables the columns to be securely fixed to the vessel. This elimination of a provision for relative sliding movements avoids the spaces or gaps between the retention members and the retained elements as occurred in prior art arrangements and, concomitantly, the danger of establishing impact forces on the retention members in the event of an accident is reduced. (author)

  5. Baking results of KSTAR vacuum vessel

    Energy Technology Data Exchange (ETDEWEB)

    Kim, S. T.; Kim, Y. J.; Kim, K. M.; Im, D. S.; Joung, N. Y.; Yang, H. L.; Kim, Y. S.; Kwon, M. [National Fusion Research Institute, Daejeon (Korea, Republic of)

    2009-05-15

    The Korea Superconducting Tokamak Advanced Research (KSTAR) is an advanced superconducting tokamak designed to establish a scientific and technological basis for an attractive fusion reactor. The fusion energy in the tokamak device is released through fusion reactions of light atoms such as deuterium or helium in hot plasma state, of which temperature reaches several hundreds of millions Celsius. The high temperature plasma is created in the vacuum vessel that provides ultra high vacuum status. Accordingly, it is most important for the vacuum condition to keep clean not only inner space but also surface of the vacuum vessel to make high quality plasma. There are two methods planned to clean the wall surface of the KSTAR vacuum vessel. One is surface baking and the other is glow discharge cleaning (GDC). To bake the vacuum vessel, De-Ionized (DI) water is heated to 130 .deg. C and circulated in the passage between double walls of the vacuum vessel (VV) in order to bake the surface. The GDC operation uses hydrogen and inert gas discharges. In this paper, general configuration and brief introduction of the baking result will be reported.

  6. Assessment of W7-X plasma vessel pressurisation in case of LOCA taking into account in-vessel components

    Energy Technology Data Exchange (ETDEWEB)

    Urbonavičius, E., E-mail: Egidijus.Urbonavicius@lei.lt; Povilaitis, M., E-mail: Mantas.Povilaitis@lei.lt; Kontautas, A., E-mail: Aurimas.Kontautas@lei.lt

    2015-11-15

    Highlights: • Analysis of the vacuum vessel response to the LOCA in W7-X was performed using lumped-parameter codes COCOSYS and ASTEC. • Benchmarking of the results received with two codes provides more confidence in results and helps in identification of possible important differences in the modelling. • The performed analysis answered the questions set in the installed plasma vessel venting system during overpressure of PV in case of 40 mm diameter LOCA in “baking” mode. • Differences in time until opening the burst disk observed in ASTEC and COCOSYS results are caused by differences in heat transfer modelling. - Abstract: This paper presents the analysis of W7-X vacuum vessel response taking into account in-vessel components. A detailed analysis of the vacuum vessel response to the loss of coolant accident was performed using lumped-parameter codes COCOSYS and ASTEC. The performed analysis showed that the installed plasma vessel venting system prevents overpressure of PV in case of 40 mm diameter LOCA in “baking” mode. The performed analysis revealed differences in heat transfer modelling implemented in ASTEC and COCOSYS computer codes, which require further investigation to justify the correct approach for application to fusion facilities.

  7. Assessment of W7-X plasma vessel pressurisation in case of LOCA taking into account in-vessel components

    International Nuclear Information System (INIS)

    Urbonavičius, E.; Povilaitis, M.; Kontautas, A.

    2015-01-01

    Highlights: • Analysis of the vacuum vessel response to the LOCA in W7-X was performed using lumped-parameter codes COCOSYS and ASTEC. • Benchmarking of the results received with two codes provides more confidence in results and helps in identification of possible important differences in the modelling. • The performed analysis answered the questions set in the installed plasma vessel venting system during overpressure of PV in case of 40 mm diameter LOCA in “baking” mode. • Differences in time until opening the burst disk observed in ASTEC and COCOSYS results are caused by differences in heat transfer modelling. - Abstract: This paper presents the analysis of W7-X vacuum vessel response taking into account in-vessel components. A detailed analysis of the vacuum vessel response to the loss of coolant accident was performed using lumped-parameter codes COCOSYS and ASTEC. The performed analysis showed that the installed plasma vessel venting system prevents overpressure of PV in case of 40 mm diameter LOCA in “baking” mode. The performed analysis revealed differences in heat transfer modelling implemented in ASTEC and COCOSYS computer codes, which require further investigation to justify the correct approach for application to fusion facilities.

  8. Social Media - DoD’s Greatest Information Sharing Tool or Weakest Security Link?

    Science.gov (United States)

    2010-04-15

    or position of the Department of the Army, Department of Defense, or the U.S. Government. SOCIAL MEDIA – DOD’S GREATEST INFORMATION SHARING TOOL...appropriateness and effectiveness of these policies in securing the information network. 15. SUBJECT TERMS Social media , information...TYPE Civilian Research Paper 3. DATES COVERED (From - To) August 2009-April 2010 4. TITLE AND SUBTITLE 5a. CONTRACT NUMBER Social Media

  9. Development of Catamaran Fishing Vessel

    Directory of Open Access Journals (Sweden)

    A. Jamaluddin

    2010-11-01

    Full Text Available Multihull due to a couple of advantages has been the topic of extensive research work in naval architecture. In this study, a series of investigation of fishing vessel to save fuel energy was carried out at ITS. Two types of ship models, monohull (round bilge and hard chine and catamaran, a boat with two hulls (symmetrical and asymmetrical were developed. Four models were produced physically and numerically, tested (towing tank and simulated numerically (CFD code. The results of the two approaches indicated that the catamaran mode might have drag (resistance smaller than those of monohull at the same displacement. A layout of catamaran fishing vessel, proposed here, indicates the freedom of setting the deck equipments for fishing vessel.

  10. Stability and accuracy of metamemory in adulthood and aging: a longitudinal analysis.

    Science.gov (United States)

    McDonald-Miszczak, L; Hertzog, C; Hultsch, D F

    1995-12-01

    The stability and accuracy of memory perceptions in 2 longitudinal samples was examined. Sample 1 consisted of 231 adults (22-78 years) tested twice over 2 years. Sample 2 consisted of 234 adults (55-86 years) tested 3 times over 6 years. Measures of perceived and actual memory change were obtained. A primary focus was whether perceptions of memory change stem from application of an implicit theory about aging and memory or from accurate monitoring of actual changes in performance. Individual differences in metamemory were highly stable over time. Results suggested at least some accurate monitoring of memory in Sample 2, in which actual change was greatest. However the overall pattern of results is largely consistent with predictions derived from an implicit theory hypothesis.

  11. Metallurgy of steels for PWR pressure vessels

    International Nuclear Information System (INIS)

    Kepka, M.; Mocek, J.; Barackova, L.

    1980-01-01

    A survey and the chemical compositions are presented of reactor pressure vessel steels. The metallurgy is described of steel making for pressure vessels in Japan and the USSR. Both acidic and alkaline open-hearth steel is used for the manufacture of ingots. The leading world manufacturers of forging ingots for pressure vessels, however, exclusively use electric steel. Vacuum casting techniques are exclusively used. Experience is shown gained with the introduction of the manufacture of forging ingots for pressure vessels at SKODA, Plzen. The metallurgical procedure was tested utilizing alkaline open hearths, electric arc furnaces and facilities for vacuum casting of steel. Pure charge raw materials should be used for securing high steel purity. Prior to forging pressure vessel rings, not only should sufficiently big bottoms and heads be removed but also the ingot middle part should be scrapped showing higher contents of impurities and nonhomogeneous structure. (B.S.)

  12. Metallurgy of steels for PWR pressure vessels

    Energy Technology Data Exchange (ETDEWEB)

    Kepka, M; Mocek, J; Barackova, L [Skoda, Plzen (Czechoslovakia)

    1980-09-01

    A survey and the chemical compositions are presented of reactor pressure vessel steels. The metallurgy is described of steel making for pressure vessels in Japan and the USSR. Both acidic and alkaline open-hearth steel is used for the manufacture of ingots. The leading world manufacturers of forging ingots for pressure vessels, however, exclusively use electric steel. Vacuum casting techniques are exclusively used. Experience is shown gained with the introduction of the manufacture of forging ingots for pressure vessels at SKODA, Plzen. The metallurgical procedure was tested utilizing alkaline open hearths, electric arc furnaces and facilities for vacuum casting of steel. Pure charge raw materials should be used for securing high steel purity. Prior to forging pressure vessel rings, not only should sufficiently big bottoms and heads be removed but also the ingot middle part should be scrapped showing higher contents of impurities and nonhomogeneous structure.

  13. Nuclear reactor vessel fuel thermal insulating barrier

    Science.gov (United States)

    Keegan, C. Patrick; Scobel, James H.; Wright, Richard F.

    2013-03-19

    The reactor vessel of a nuclear reactor installation which is suspended from the cold leg nozzles in a reactor cavity is provided with a lower thermal insulating barrier spaced from the reactor vessel that has a hemispherical lower section that increases in volume from the center line of the reactor to the outer extent of the diameter of the thermal insulating barrier and smoothly transitions up the side walls of the vessel. The space between the thermal insulating harrier and the reactor vessel forms a chamber which can be flooded with cooling water through passive valving to directly cool the reactor vessel in the event of a severe accident. The passive inlet valve for the cooling water includes a buoyant door that is normally maintained sealed under its own weight and floats open when the cavity is Hooded. Passively opening steam vents are also provided.

  14. Isothermal and thermal–mechanical fatigue of VVER-440 reactor pressure vessel steels

    Energy Technology Data Exchange (ETDEWEB)

    Fekete, Balazs, E-mail: fekete.mm.bme@gmail.com [College of Dunaujvaros, Tancsics 1A, Dunaujvaros H-2400 (Hungary); Department of Applied Mechanics, Budapest University of Technology and Economics, Muegyetem 5, Budapest H-1111 (Hungary); Trampus, Peter [College of Dunaujvaros, Tancsics 1A, Dunaujvaros H-2400 (Hungary)

    2015-09-15

    Highlights: • We aimed to determine the thermomechanical behaviour of VVER reactor steels. • Material tests were developed and performed on GLEEBLE 3800 physical simulator. • Coffin–Manson curves and parameters were derived. • High accuracy of the strain energy based evaluation was found. • The observed dislocation evolution correlates with the mechanical behaviour. - Abstract: The fatigue life of the structural materials 15Ch2MFA (CrMoV-alloyed ferritic steel) and 08Ch18N10T (CrNi-alloyed austenitic steel) of VVER-440 reactor pressure vessel under completely reserved total strain controlled low cycle fatigue tests were investigated. An advanced test facility was developed for GLEEBLE-3800 physical simulator which was able to perform thermomechanical fatigue experiments under in-service conditions of VVER nuclear reactors. The low cycle fatigue results were evaluated with the plastic strain based Coffin–Manson law, and plastic strain energy based model as well. It was shown that both methods are able to predict the fatigue life of reactor pressure vessel steels accurately. Interrupted fatigue tests were also carried out to investigate the kinetic of the fatigue evolution of the materials. On these samples microstructural evaluation by TEM was performed. The investigated low cycle fatigue behavior can provide reference for remaining life assessment and lifetime extension analysis.

  15. Intraabdominal laparoscopy-assisted "open" vessel ligation of testicular vessels: a potential treatment for varicocele.

    Science.gov (United States)

    Miyano, Go; Miyahara, Katsumi; Halibieke, Abudebieke; Lane, Geoffrey J; Okazaki, Tadaharu; Yamataka, Atsuyuki

    2011-10-01

    We tested our laparoscopy-assisted "open" ligation (LOL) technique on testicular vessels. We ligated the left testicular artery and vein (TAV) in 8-week-old male Wister rats using LOL (LOL group; n=10) or laparotomy (open group; n=10). In LOL, a 0-degree laparoscope was introduced through a 5-mm epigastric trocar. A 3-mm grasper was used to expose the left TAV. A lapa-her-closure (LHC) needle loaded with 3-0 SurgiPro was directly inserted into the left lower quadrant where the left TAV should be and advanced under the vessels, and the suture material was released leaving one end outside. The LHC was then withdrawn a little and advanced again over the vessels to grasp the end of the suture material just released to bring it outside. This was proximally repeated. The two ends of both sutures were conventionally tied outside, and the knot was passed through the insertion site and tightened around the vessels. In the open group, the left TAV were ligated using two 3-0 SurgiPro ties. In both groups, the right side was left intact. All rats were sacrificed 2 weeks postoperatively, and both testes were examined with hematoxylin and eosin. Treatment time was 5-7 minutes for LOL and 7-8 minutes for the open group. Postoperative recovery was uneventful. No adhesions were present between the ligated vessels and bowel in any rat. Histopathology of all left testes showed coagulative necrosis of germinal cells and seminiferous tubules; all right testes were normal. LOL appears to be as effective as open ligation and may find application for treating varicocele.

  16. Assessment of peripheral vessels and of the lymphatic system by means of gamma-camera scintiscan (gamma-scintigraphy of the whole body)

    Energy Technology Data Exchange (ETDEWEB)

    Ennis, J T

    1981-01-01

    For diagnosing pathologies of the peripheric vessels or of the lymphatic system, albumin aggregates marked with sup(99m) technetium (MAA) or antimonocolloids were used. The radionuclide venography is useful in diagnosing thrombosis, venous insufficiency, and permits a high degree of accuracy, comparable with that of phlebography. In the most cases the radionuclide lymphoscintigraphy is required for the diagnosis of lymphoedema and allows by distribution analysis an adequate morphological representation of the lymphatic ducts and glands. Contrary to lymphography, lymphoscintigraphy presents a completely physiological radionuclide transport and does not cause any reactive lymphatic node hyperplasia by contrast media. Increased capillary perfusion is found in collateral vessel formation in cases of arterial obstruction and ischaemic ulcus, whereas hypoperfusion is seen in obstructions of the larger arteries having no collateral vessels, and in bad circulatory states. Particularly in diabetics with microangiopathy, a peripheral distribution with hyperfusion of the skon presents itself as piece-meal necrosis. The importance and relevance of the perfusion scans of the extremities for the diagnostic assessment within the field of resection surgery is explained.

  17. Cheboygan Vessel Base

    Data.gov (United States)

    Federal Laboratory Consortium — Cheboygan Vessel Base (CVB), located in Cheboygan, Michigan, is a field station of the USGS Great Lakes Science Center (GLSC). CVB was established by congressional...

  18. Reactor pressure vessel embrittlement management through EPRI-Developed material property databases

    International Nuclear Information System (INIS)

    Rosinski, S.T.; Server, W.L.; Griesbach, T.J.

    1997-01-01

    Uncertainties and variability in U.S. reactor pressure vessel (RPV) material properties have caused the U.S. Nuclear Regulatory Commission (NRC) to request information from all nuclear utilities in order to assess the impact of these data scatter and uncertainties on compliance with existing regulatory criteria. Resolving the vessel material uncertainty issues requires compiling all available data into a single integrated database to develop a better understanding of irradiated material property behavior. EPRI has developed two comprehensive databases for utility implementation to compile and evaluate available material property and surveillance data. RPVDATA is a comprehensive reactor vessel materials database and data management program that combines data from many different sources into one common database. Searches of the data can be easily performed to identify plants with similar materials, sort through measured test results, compare the ''best-estimates'' for reported chemistries with licensing basis values, quantify variability in measured weld qualification and test data, identify relevant surveillance results for characterizing embrittlement trends, and resolve uncertainties in vessel material properties. PREP4 has been developed to assist utilities in evaluating existing unirradiated and irradiated data for plant surveillance materials; PREP4 evaluations can be used to assess the accuracy of new trend curve predictions. In addition, searches of the data can be easily performed to identify available Charpy shift and upper shelf data, review surveillance material chemistry and fabrication information, review general capsule irradiation information, and identify applicable source reference information. In support of utility evaluations to consider thermal annealing as a viable embrittlement management option, EPRI is also developing a database to evaluate material response to thermal annealing. Efforts are underway to develop an irradiation

  19. Influence of the number of energy groups on the accuracy of neutron fluence calculations

    International Nuclear Information System (INIS)

    Barz, H.U.; Konheiser, J.

    1999-01-01

    The question how many groups are necessary to obtain all needed integral quantities for the neutron load of pressure vessels and detector positions outside the vessel with sufficient accuracy is of general interest. Until now, there are no systematic investigations on this question. In principle 3-dimensional consideration is required for such neutron load calculations. Therefore, an estimation of the needed number of groups can be of interest to minimize calculation time. One general problem is the P L -approximation of the angular distributions for the transfers between different groups. For elastic scattering this P L -approximation becomes poorer with increasing number of groups. As deterministic methods generally use the P L -approximation they cannot be used for investigations of the errors caused by the group approximation. We have investigated this problem applying group Monte-Carlo but nearly exact representation of this elastic slowing down without P L -approximation. The calculations were directed to assess the neutron fluence of a Russian WWER-1000 reactor. For that a simplified geometrical model of this reactor type has been used. (orig.)

  20. Reactors with pressure vessel in pre-stressed concrete

    International Nuclear Information System (INIS)

    Devillers, Christian; Lafore, Pierre

    1964-12-01

    After having proposed a general description of the evolution of the general design of reactors with a vessel in pre-stressed concrete, this report outlines the interest of this technical solution of a vessel in pre-stressed concrete with integrated exchangers, which is to replace steel vessel. This solution is presented as much safer. The authors discuss the various issues related to protection: inner and outer biological protection of the vessel, material protection (against heating, steel irradiation, Wigner effect, and moderator radiolytic corrosion). They report the application of calculation methods: calculation of vessel concrete heating, study of the intermediate zone in integrated reactors, neutron spectrum and flows in the core of a graphite pile

  1. Computerized reactor pressure vessel materials information system

    International Nuclear Information System (INIS)

    Strosnider, J.; Monserrate, C.; Kenworthy, L.D.; Tether, C.D.

    1980-10-01

    A computerized information system for storage and retrieval of reactor pressure vessel materials data was established, as part of Task Action Plan A-11, Reactor Vessel Materials Toughness. Data stored in the system are necessary for evaluating the resistance of reactor pressure vessels to flaw-induced fracture. This report includes (1) a description of the information system; (2) guidance on accessing the system; and (3) a user's manual for the system

  2. How to replace a reactor pressure vessel

    International Nuclear Information System (INIS)

    Huber, R.

    1996-01-01

    A potential life extending procedure for a nuclear reactor after, say, 40 years of service life, might in some circumstances be the replacement of the reactor pressure vessel. Neutron induced degradation of the vessel might make replacement by one of a different material composition desirable, for example. Although the replacement of heavy components, such as steam generators, has been possible for many years, the pressure vessel presents a much more demanding task if only because it is highly irradiated. Some preliminary feasibility studies by Siemens are reported for the two removal strategies that might be considered. These are removal of the entire pressure vessel in one piece and dismantling it into sections. (UK)

  3. TMI-2 Vessel Investigation Project integration report

    Energy Technology Data Exchange (ETDEWEB)

    Wolf, J. R.; Rempe, J. L.; Stickler, L. A.; Korth, G. E.; Diercks, D. R.; Neimark, L. A.; Akers, D W; Schuetz, B. K.; Shearer, T L; Chavez, S. A.; Thinnes, G. L.; Witt, R. J.; Corradini, M L; Kos, J. A. [EG and G Idaho, Inc., Idaho Falls, ID (United States)

    1994-03-01

    The Three Mile Island Unit 2 (TMI-2) Vessel Investigation Project (VIP) was an international effort that was sponsored by the Nuclear Energy Agency of the Organization for Economic Cooperation and Development. The primary objectives of the VIP were to extract and examine samples from the lower head and to evaluate the potential modes of failure and the margin of structural integrity that remained in the TMI-2 reactor vessel during the accident. This report presents a summary of the major findings and conclusions that were developed from research during the VIP. Results from the various elements of the project are integrated to form a cohesive understanding of the vessel`s condition after the accident.

  4. Lung vessel segmentation in CT images using graph-cuts

    Science.gov (United States)

    Zhai, Zhiwei; Staring, Marius; Stoel, Berend C.

    2016-03-01

    Accurate lung vessel segmentation is an important operation for lung CT analysis. Filters that are based on analyzing the eigenvalues of the Hessian matrix are popular for pulmonary vessel enhancement. However, due to their low response at vessel bifurcations and vessel boundaries, extracting lung vessels by thresholding the vesselness is not sufficiently accurate. Some methods turn to graph-cuts for more accurate segmentation, as it incorporates neighbourhood information. In this work, we propose a new graph-cuts cost function combining appearance and shape, where CT intensity represents appearance and vesselness from a Hessian-based filter represents shape. Due to the amount of voxels in high resolution CT scans, the memory requirement and time consumption for building a graph structure is very high. In order to make the graph representation computationally tractable, those voxels that are considered clearly background are removed from the graph nodes, using a threshold on the vesselness map. The graph structure is then established based on the remaining voxel nodes, source/sink nodes and the neighbourhood relationship of the remaining voxels. Vessels are segmented by minimizing the energy cost function with the graph-cuts optimization framework. We optimized the parameters used in the graph-cuts cost function and evaluated the proposed method with two manually labeled sub-volumes. For independent evaluation, we used 20 CT scans of the VESSEL12 challenge. The evaluation results of the sub-volume data show that the proposed method produced a more accurate vessel segmentation compared to the previous methods, with F1 score 0.76 and 0.69. In the VESSEL12 data-set, our method obtained a competitive performance with an area under the ROC curve of 0.975, especially among the binary submissions.

  5. Effects of accuracy motivation and anchoring on metacomprehension judgment and accuracy.

    Science.gov (United States)

    Zhao, Qin

    2012-01-01

    The current research investigates how accuracy motivation impacts anchoring and adjustment in metacomprehension judgment and how accuracy motivation and anchoring affect metacomprehension accuracy. Participants were randomly assigned to one of six conditions produced by the between-subjects factorial design involving accuracy motivation (incentive or no) and peer performance anchor (95%, 55%, or no). Two studies showed that accuracy motivation did not impact anchoring bias, but the adjustment-from-anchor process occurred. Accuracy incentive increased anchor-judgment gap for the 95% anchor but not for the 55% anchor, which induced less certainty about the direction of adjustment. The findings offer support to the integrative theory of anchoring. Additionally, the two studies revealed a "power struggle" between accuracy motivation and anchoring in influencing metacomprehension accuracy. Accuracy motivation could improve metacomprehension accuracy in spite of anchoring effect, but if anchoring effect is too strong, it could overpower the motivation effect. The implications of the findings were discussed.

  6. Temporary shielding of hot spots in the drainage areas of cutaneous melanoma improves accuracy of lymphoscintigraphic sentinel lymph node diagnostics

    International Nuclear Information System (INIS)

    Maza, S.; Valencia, R.; Geworski, L.; Zander, A.; Munz, D.L.; Draeger, E.; Winter, H.; Sterry, W.

    2002-01-01

    Detection of the ''true'' sentinel lymph nodes, permitting correct staging of regional lymph nodes, is essential for management and prognostic assessment in malignant melanoma. In this study, it was prospectively evaluated whether simple temporary shielding of hot spots in lymphatic drainage areas could improve the accuracy of sentinel lymph node diagnostics. In 100 consecutive malignant melanoma patients (45 women, 55 men; age 11-91 years), dynamic and static lymphoscintigraphy in various views was performed after strict intracutaneous application of technetium-99m nanocolloid (40-150 MBq; 0.05 ml/deposit) around the tumour (31 patients) or the biopsy scar (69 patients, safety distance 1 cm). The images were acquired with and without temporary lead shielding of the most prominent hot spots in the drainage area. In 33/100 patients, one or two additional sentinel lymph nodes that showed less tracer accumulation or were smaller (<1.5 cm) were detected after shielding. Four of these patients had metastases in the sentinel lymph nodes; the non-sentinel lymph nodes were tumour negative. In 3/100 patients, hot spots in the drainage area proved to be lymph vessels, lymph vessel intersections or lymph vessel ectasias after temporary shielding; hence, a node interpreted as a non-sentinel lymph node at first glance proved to be the real sentinel lymph node. In two of these patients, lymph node metastasis was histologically confirmed; the non-sentinel lymph nodes were tumour free. In 7/100 patients the exact course of lymph vessels could be mapped after shielding. In one of these patients, two additional sentinel lymph nodes (with metastasis) were detected. Overall, in 43/100 patients the temporary shielding yielded additional information, with sentinel lymph node metastases in 7%. In conclusion, when used in combination with dynamic acquisition in various views, temporary shielding of prominent hot spots in the drainage area of a malignant melanoma of the skin leads to an

  7. Blood Vessels in Allotransplantation.

    Science.gov (United States)

    Abrahimi, P; Liu, R; Pober, J S

    2015-07-01

    Human vascularized allografts are perfused through blood vessels composed of cells (endothelium, pericytes, and smooth muscle cells) that remain largely of graft origin and are thus subject to host alloimmune responses. Graft vessels must be healthy to maintain homeostatic functions including control of perfusion, maintenance of permselectivity, prevention of thrombosis, and participation in immune surveillance. Vascular cell injury can cause dysfunction that interferes with these processes. Graft vascular cells can be activated by mediators of innate and adaptive immunity to participate in graft inflammation contributing to both ischemia/reperfusion injury and allograft rejection. Different forms of rejection may affect graft vessels in different ways, ranging from thrombosis and neutrophilic inflammation in hyperacute rejection, to endothelialitis/intimal arteritis and fibrinoid necrosis in acute cell-mediated or antibody-mediated rejection, respectively, and to diffuse luminal stenosis in chronic rejection. While some current therapies targeting the host immune system do affect graft vascular cells, direct targeting of the graft vasculature may create new opportunities for preventing allograft injury and loss. © Copyright 2015 The American Society of Transplantation and the American Society of Transplant Surgeons.

  8. Irradiation embrittlement of reactor vessel steels

    International Nuclear Information System (INIS)

    Bros, J.

    2000-01-01

    From the historical decision of closing the Yankee Rowe NPP because of the uncertainties on the level of reactor pressure vessel neutron embrittlement, this paper reviews the technical-scientist bases of the degradation phenomena, and refers to the evolution of reactor pressure vessel radiation surveillance programs. (Author)

  9. Improved Accuracy of Myocardial Perfusion SPECT for the Detection of Coronary Artery Disease by Utilizing a Support Vector Machines Algorithm

    Science.gov (United States)

    Arsanjani, Reza; Xu, Yuan; Dey, Damini; Fish, Matthews; Dorbala, Sharmila; Hayes, Sean; Berman, Daniel; Germano, Guido; Slomka, Piotr

    2012-01-01

    We aimed to improve the diagnostic accuracy of automatic myocardial perfusion SPECT (MPS) interpretation analysis for prediction of coronary artery disease (CAD) by integrating several quantitative perfusion and functional variables for non-corrected (NC) data by support vector machines (SVM), a computer method for machine learning. Methods 957 rest/stress 99mtechnetium gated MPS NC studies from 623 consecutive patients with correlating invasive coronary angiography and 334 with low likelihood of CAD (LLK < 5% ) were assessed. Patients with stenosis ≥ 50% in left main or ≥ 70% in all other vessels were considered abnormal. Total perfusion deficit (TPD) was computed automatically. In addition, ischemic changes (ISCH) and ejection fraction changes (EFC) between stress and rest were derived by quantitative software. The SVM was trained using a group of 125 pts (25 LLK, 25 0-, 25 1-, 25 2- and 25 3-vessel CAD) using above quantitative variables and second order polynomial fitting. The remaining patients (N = 832) were categorized based on probability estimates, with CAD defined as (probability estimate ≥ 0.50). The diagnostic accuracy of SVM was also compared to visual segmental scoring by two experienced readers. Results Sensitivity of SVM (84%) was significantly better than ISCH (75%, p < 0.05) and EFC (31%, p < 0.05). Specificity of SVM (88%) was significantly better than that of TPD (78%, p < 0.05) and EFC (77%, p < 0.05). Diagnostic accuracy of SVM (86%) was significantly better than TPD (81%), ISCH (81%), or EFC (46%) (p < 0.05 for all). The Receiver-operator-characteristic area-under-the-curve (ROC-AUC) for SVM (0.92) was significantly better than TPD (0.90), ISCH (0.87), and EFC (0.60) (p < 0.001 for all). Diagnostic accuracy of SVM was comparable to the overall accuracy of both visual readers (85% vs. 84%, p < 0.05). ROC-AUC for SVM (0.92) was significantly better than that of both visual readers (0.87 and 0.88, p < 0.03). Conclusion Computational

  10. Exponential Stabilization of an Underactuated Surface Vessel

    Directory of Open Access Journals (Sweden)

    Kristin Y. Pettersen

    1997-07-01

    Full Text Available The paper shows that a large class of underactuated vehicles cannot be asymptotically stabilized by either continuous or discontinuous state feedback. Furthermore, stabilization of an underactuated surface vessel is considered. Controllability properties of the surface vessels is presented, and a continuous periodic time-varying feedback law is proposed. It is shown that this feedback law exponentially stabilizes the surface vessel to the origin, and this is illustrated by simulations.

  11. Ocean Station Vessel

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Ocean Station Vessels (OSV) or Weather Ships captured atmospheric conditions while being stationed continuously in a single location. While While most of the...

  12. Superior long term outcome associated with native vessel versus graft vessel PCI following secondary PCI in patients with prior CABG.

    Science.gov (United States)

    Mavroudis, Chrysostomos A; Kotecha, Tushar; Chehab, Omar; Hudson, Jonathan; Rakhit, Roby D

    2017-02-01

    Secondary percutaneous coronary intervention (PCI) in patients with prior coronary artery bypass graft surgery is increasingly common. Graft vessel PCI has higher rates of adverse events compared with native coronary vessel PCI. To investigate the clinical outcomes of patients with prior CABG who underwent secondary PCI of either a graft vessel (GV), a native coronary vessel (NV) or both graft and native (NG) vessels. 220 patients (84% male) who underwent PCI in our institution to either GV (n=89), NV (n=103) or both GV and NV (NG group) (n=28) were studied. The study population underwent 378 procedures (GV group; n=126, NV group; n=164 and NG group; n=88). Median follow up was for 36months [range 2-75months]. Target vessel revascularisation (TVR) occurred in 12.5% of the GV group and 3.6% in the NV group [p=0.0004], and was predominantly due to in-stent restenosis. Patients who had PCI due to TVR were more likely to suffer from diabetes and peripheral vascular disease. History of chronic renal failure was associated with higher risk (HR 2.21, p=0.005) whereas preserved left ventricular ejection fraction (LVEF) with lower risk (HR 0.17, p=0.0007) of death. The median survival (interval between CABG and end of follow-up period) was lower in the GV compared with the NV group (315 vs 372months p=0.005). This registry demonstrates inferior long term outcome for patients undergoing secondary PCI of GV versus NV. Where possible, a strategy of NV rather than GV target PCI should be considered in patients with prior CABG. Secondary PCI in patients with prior CABG surgery is increasingly common. Graft vessel PCI has inferior outcomes with high rates of restenosis and occlusion compared with native coronary vessel PCI. We studied the clinical outcomes of 220 patients with prior CABG who underwent secondary PCI to either a graft vessel (GV), a native coronary vessel (NV) or both graft and native (NG) vessels. Target vessel revascularisation was 5 times higher in the GV

  13. Improvement of shipborne sky radiometer and its demonstration aboard the Antarctic research vessel Shirase

    Directory of Open Access Journals (Sweden)

    Noriaki Tanaka

    2014-11-01

    Full Text Available The sun-tracking performance of a shipborne sky radiometer was improved to attain accurate aerosol optical thickness (AOT from direct solar measurements on a pitching and rolling vessel. Improvements were made in the accuracy of sun-pointing measurements, field-of-view expansion, sun-tracking speed, and measurement method. Radiometric measurements of direct solar and sky brightness distribution were performed using the shipborne sky radiometer onboard the Antarctic research vessel (R/V Shirase during JARE-51 (2009-2010 and JARE-52 (2010-2011. The temporal variation of signal intensity measured by the radiometer under cloudless conditions was smooth, demonstrating that the radiometer could measure direct sunlight onboard the R/V. AOT at 500 nm ranged from 0.01 to 0.34, and values over Southeast Asia and over the western Pacific Ocean in spring were higher than those over other regions. The Angstrom exponent ranged from -0.06 to 2.00, and values over Southeast Asia and off the coast near Sydney were the highest. The improved shipborne sky radiometer will contribute to a good understanding of the nature of aerosols over the ocean.

  14. Analyzing Vessel Behavior Using Process Mining

    NARCIS (Netherlands)

    Maggi, F.M.; Mooij, A.J.; Aalst, W.M.P. van der

    2013-01-01

    In the maritime domain, electronic sensors such as AIS receivers and radars collect large amounts of data about the vessels in a certain geographical area. We investigate the use of process mining techniques for analyzing the behavior of the vessels based on these data. In the context of maritime

  15. 2011 Vessel Density

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Automatic Identification Systems (AIS) are a navigation safety device that transmits and monitors the location and characteristics of many vessels in U.S. and...

  16. 2013 Vessel Density

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Automatic Identification Systems (AIS) are a navigation safety device that transmits and monitors the location and characteristics of many vessels in U.S. and...

  17. Calculation of neutron fluence in the region of the pressure vessel for the history of different reactors by using the Monte-Carlo-method

    International Nuclear Information System (INIS)

    Barz, H.U.; Bertram, W.

    1992-01-01

    Embrittlement of pressure vessel material caused by neutron irradiation is a very important problem for VVER-440 reactors. For the estimation of the fracture risk highly reliable neutron fluence values are necessary. For this reason a special theoretical determination of space dependent neutron fluences has been performed mainly on the basis of Monte-Carlo calculations. The described method allows the accurate calculation of neutron fluences near the pressure vessel in the height of the core region for all reactor histories and loading cycles in an efficient manner. To illustrate the accuracy of the suggested method a comparison with experimental results was done. The calculated neutron fluence values can be used for planning the loading schemes of each reactor according to the safety requirements against brittle fracture. (orig.)

  18. Analysis of cracked pressure vessel nozzles by finite elements

    International Nuclear Information System (INIS)

    Reynen, J.

    1975-01-01

    The paper describes various algorithms, their computer implementations and relative merits to define in an effective way strain energy release rates along the tip front of arbitrary 3D cracks under arbitrary load including thermal strains. These techniques are basically equivalent to substructuring techniques and consequently they can be implemented to any FEM program able to deal with the data handling problems of the substructuring technique. Special finite elements with a built-in stress-singularity are not necessary although their use contributes to accuracy and the mesh can be coarser. Examples are given carried out with a substructure version of the BERSAFE system. These examples include a corner crack in a pressure vessel nozzle loaded by internal pressure and by thermal stresses. Although not of any fundamental importance, in practice the difficulties consist in generating an appropriate mesh to represent the crack front. For the example of the corner crack in a nozzle the problem has been solved by developing a special purpose mesh generation program (EURCRACK)

  19. Image quality, radiation dose, and diagnostic accuracy of prospectively ECG-triggered high-pitch coronary CT angiography at 70 kVp in a clinical setting: comparison with invasive coronary angiography

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, Long Jiang; Qi, Li; Zhou, Chang Sheng; Zhao, Yan E.; Li, Xie; Lu, Guang Ming [Jinling Hospital, Medical School of Nanjing University, Department of Medical Imaging, Nanjing, Jiangsu (China); Wang, Yining; Cao, Jian; Jin, Zhengyu [Peking Union Medical College Hospital, Department of Radiology, Beijing (China); Schoepf, U.J. [Jinling Hospital, Medical School of Nanjing University, Department of Medical Imaging, Nanjing, Jiangsu (China); Medical University of South Carolina, Division of Cardiovascular Imaging, Charleston, SC (United States); Meinel, Felix G. [Medical University of South Carolina, Division of Cardiovascular Imaging, Charleston, SC (United States); Ludwig-Maximilians-University Hospital, Institute for Clinical Radiology, Munich (Germany); Bayer, Richard R. [Medical University of South Carolina, Division of Cardiovascular Imaging, Charleston, SC (United States); Gong, Jian Bin [Jinling Hospital, Medical School of Nanjing University, Department of Cardiology, Nanjing, Jiangsu (China)

    2016-03-15

    To investigate image quality, radiation dose, and diagnostic performance of prospectively ECG-triggered high-pitch coronary CT angiography (CCTA) at 70 kVp compared to invasive coronary angiography (ICA) as reference standard. Forty-three patients underwent prospectively ECG-triggered high-pitch CCTA at 70 kVp using 30 cc (11 g iodine) contrast medium and ICA. Subjective and objective image quality was evaluated for each CCTA study. CCTA performance for diagnosing ≥50 % stenosis was assessed. Results were stratified according to heart rate (HR), body mass index (BMI), Agatston score, and image quality. At CCTA, 94.3 % (500/530) of coronary segments were of diagnostic quality. Using ICA as reference standard, sensitivity and accuracy were 100 % and 93.0 % on a per-patient basis. Per-vessel and per-segment performances were 92.2 % and 89.5 %; 79.5 % and 88.3 %, respectively. No differences were found in diagnostic accuracy between different HR, BMI, and calcification subgroups (all P > 0.05) on a per-patient basis. However, low image quality reduced diagnostic accuracy on a per-patient, per-vessel and per-segment basis (all P < 0.05). The mean effective radiation dose was 0.2 ± 0.0 mSv. Our presented protocol results in an effective radiation dose of 0.2 mSv and high diagnostic accuracy for stenosis detection in a selected, non-obese population. (orig.)

  20. Models and Algorithms for Container Vessel Stowage Optimization

    DEFF Research Database (Denmark)

    Delgado-Ortegon, Alberto

    .g., selection of vessels to buy that satisfy specific demands), through to operational decisions (e.g., selection of containers that optimize revenue, and stowing those containers into a vessel). This thesis addresses the question of whether it is possible to formulate stowage optimization models...... container of those to be loaded in a port should be placed in a vessel, i.e., to generate stowage plans. This thesis explores two different approaches to solve this problem, both follow a 2-phase decomposition that assigns containers to vessel sections in the first phase, i.e., master planning...

  1. Sealing analysis for nuclear vessels of PWR

    International Nuclear Information System (INIS)

    Qu Jiadi; Dou Yikang

    1988-01-01

    The fundamental equations of sealing analysis for vessels are given and a computer program named SMEC, which considers the change of stud loading, the elastic contact between flange mating surfaces and the transient thermal effects, is developed accordingly. The SMEC is verified by several test. On the basis of analysis, a new concept of classifying vessels into three types according to increasing or decreasing of bolt loading with increasing pressure is suggested. Type-A vessel is that in which the bolt loading increases monotonically with increasing pressure, while in type-B, the bolt loading decreases monotonically, and in type-C, the bolt loading changes nonmonotonically. It is important for vessel design to distinguish the types through analysis. The sealing mechanism is also discussed

  2. Method to moor an offshore operating vessel

    Energy Technology Data Exchange (ETDEWEB)

    Flory, J.F.

    1983-01-24

    A vessel such as a storage vessel is permanently moored, by means such as a yoke pivoted on the forecastle of the vessel, to a mooring leg, e.g. a riser or anchor chain, which is attached to a base located on the ocean floor. Mounted on the vessel is tension exsisting means, for example, counterweights, springs, winches, or the like, operably connected with the mooring leg for applying tension thereto such as by lifting the yoke. The top of the mooring leg is connected to the end of the yoke through a mooring swivel and a gimbaled mooring table or a universal joint. A fluid swivel may be located above the mooring table or about a load-carrying shaft connected to the mooring leg. 8 drawings.

  3. MRA of fibromuscular dysplasia in cervical vessels

    International Nuclear Information System (INIS)

    Link, J.; Steffens, J.C.; Mueller-Huelsbeck, S.; Brossmann, J.; Heller, M.

    1996-01-01

    In 386 selective angiograms of cervical vessels fibromuscular dysplasia was revealed in 4 female patients in the age of 30-54 years. FMD was located in the carotid artery (n=5) and in the vertebral artery (n=2) with a total of 8 lesions. 6/8 of the lesions of the seven cervical vessels were located typically in the mid cervical portion of the vessels and 2/6 lesions were located in the atlas loop of the vertebral artery. 4 lesions showed moderate stenosis and 4 vessels showed only mild stenosis. These patterns which demonstrated the typical morphology of fibromuscular dysplasia with alternating irregular zones of widening and narrowing were evaluated well with MR angiography, the others were missed. (orig./MG) [de

  4. Retinal Vessels Segmentation Techniques and Algorithms: A Survey

    Directory of Open Access Journals (Sweden)

    Jasem Almotiri

    2018-01-01

    Full Text Available Retinal vessels identification and localization aim to separate the different retinal vasculature structure tissues, either wide or narrow ones, from the fundus image background and other retinal anatomical structures such as optic disc, macula, and abnormal lesions. Retinal vessels identification studies are attracting more and more attention in recent years due to non-invasive fundus imaging and the crucial information contained in vasculature structure which is helpful for the detection and diagnosis of a variety of retinal pathologies included but not limited to: Diabetic Retinopathy (DR, glaucoma, hypertension, and Age-related Macular Degeneration (AMD. With the development of almost two decades, the innovative approaches applying computer-aided techniques for segmenting retinal vessels are becoming more and more crucial and coming closer to routine clinical applications. The purpose of this paper is to provide a comprehensive overview for retinal vessels segmentation techniques. Firstly, a brief introduction to retinal fundus photography and imaging modalities of retinal images is given. Then, the preprocessing operations and the state of the art methods of retinal vessels identification are introduced. Moreover, the evaluation and validation of the results of retinal vessels segmentation are discussed. Finally, an objective assessment is presented and future developments and trends are addressed for retinal vessels identification techniques.

  5. Three Dimensional Shallow Water Adaptive Hydraulics (ADH-SW3): Waterborne Vessels

    Science.gov (United States)

    2015-10-01

    Type Value Description 1 char CBOW Card type 2 int > 0 Vessel number 3 real # Ratio of vessel bow to vessel draft CSTR FRACTION OF DRAFT...APPLIED TO PSTR Field Type Value Description 1 char CSTR Card type 2 int > 0 Vessel number 3 real # Ratio of vessel stern to vessel draft PROP

  6. Roi Detection and Vessel Segmentation in Retinal Image

    Science.gov (United States)

    Sabaz, F.; Atila, U.

    2017-11-01

    Diabetes disrupts work by affecting the structure of the eye and afterwards leads to loss of vision. Depending on the stage of disease that called diabetic retinopathy, there are sudden loss of vision and blurred vision problems. Automated detection of vessels in retinal images is a useful study to diagnose eye diseases, disease classification and other clinical trials. The shape and structure of the vessels give information about the severity of the disease and the stage of the disease. Automatic and fast detection of vessels allows for a quick diagnosis of the disease and the treatment process to start shortly. ROI detection and vessel extraction methods for retinal image are mentioned in this study. It is shown that the Frangi filter used in image processing can be successfully used in detection and extraction of vessels.

  7. Power reactor pressure vessel benchmarks

    International Nuclear Information System (INIS)

    Rahn, F.J.

    1978-01-01

    A review is given of the current status of experimental and calculational benchmarks for use in understanding the radiation embrittlement effects in the pressure vessels of operating light water power reactors. The requirements of such benchmarks for application to pressure vessel dosimetry are stated. Recent developments in active and passive neutron detectors sensitive in the ranges of importance to embrittlement studies are summarized and recommendations for improvements in the benchmark are made. (author)

  8. Prediction of Large Vessel Occlusions in Acute Stroke: National Institute of Health Stroke Scale Is Hard to Beat.

    Science.gov (United States)

    Vanacker, Peter; Heldner, Mirjam R; Amiguet, Michael; Faouzi, Mohamed; Cras, Patrick; Ntaios, George; Arnold, Marcel; Mattle, Heinrich P; Gralla, Jan; Fischer, Urs; Michel, Patrik

    2016-06-01

    Endovascular treatment for acute ischemic stroke with a large vessel occlusion was recently shown to be effective. We aimed to develop a score capable of predicting large vessel occlusion eligible for endovascular treatment in the early hospital management. Retrospective, cohort study. Two tertiary, Swiss stroke centers. Consecutive acute ischemic stroke patients (1,645 patients; Acute STroke Registry and Analysis of Lausanne registry), who had CT angiography within 6 and 12 hours of symptom onset, were categorized according to the occlusion site. Demographic and clinical information was used in logistic regression analysis to derive predictors of large vessel occlusion (defined as intracranial carotid, basilar, and M1 segment of middle cerebral artery occlusions). Based on logistic regression coefficients, an integer score was created and validated internally and externally (848 patients; Bernese Stroke Registry). None. Large vessel occlusions were present in 316 patients (21%) in the derivation and 566 (28%) in the external validation cohort. Five predictors added significantly to the score: National Institute of Health Stroke Scale at admission, hemineglect, female sex, atrial fibrillation, and no history of stroke and prestroke handicap (modified Rankin Scale score, < 2). Diagnostic accuracy in internal and external validation cohorts was excellent (area under the receiver operating characteristic curve, 0.84 both). The score performed slightly better than National Institute of Health Stroke Scale alone regarding prediction error (Wilcoxon signed rank test, p < 0.001) and regarding discriminatory power in derivation and pooled cohorts (area under the receiver operating characteristic curve, 0.81 vs 0.80; DeLong test, p = 0.02). Our score accurately predicts the presence of emergent large vessel occlusions, which are eligible for endovascular treatment. However, incorporation of additional demographic and historical information available on hospital arrival

  9. Four-dimensional (4D) flow of the whole heart and great vessels using real-time respiratory self-gating

    DEFF Research Database (Denmark)

    Uribe, Sergio; Beerbaum, Philipp; Sørensen, Thomas Sangild

    2009-01-01

    Four-dimensional (4D) flow imaging has been used to study flow patterns and pathophysiology, usually focused on specific thoracic vessels and cardiac chambers. Whole-heart 4D flow at high measurement accuracy covering the entire thoracic cardiovascular system would be desirable to simplify...... and improve hemodynamic assessment. This has been a challenge because compensation of respiratory motion is difficult to achieve, but it is paramount to limit artifacts and improve accuracy. In this work we propose a self-gating technique for respiratory motion-compensation integrated into a whole-heart 4D...... flow acquisition that overcomes these challenges. Flow components are measured in all three directions for each pixel over the complete cardiac cycle, and 1D volume projections are obtained at certain time intervals for respiratory gating in real time during the acquisition. The technique was tested...

  10. Commissioning result of the KSTAR in-vessel cryo-pump

    Energy Technology Data Exchange (ETDEWEB)

    Chang, Y. B.; Lee, H. J.; Park, Y.M. [National Fusion Research Institute, Daejeon (Korea, Republic of); and others

    2013-12-15

    KSTAR in-vessel cryo-pump has been installed in the vacuum vessel top and bottom side with up-down symmetry for the better plasma density control in the D-shape H-mode. The cryogenic helium lines of the in-vessel cryo-pump are located at the vertical positions from the vacuum vessel torus center 2,000 mm. The inductive electrical potential has been optimized to reduce risk of electrical breakdown during plasma disruption. In-vessel cryo-pump consists of three parts of coaxial circular shape components; cryo-panel, thermal shield and particle shield. The cryo-panel is cooled down to below 4.5 K. The cryo-panel and thermal shields were made by Inconel 625 tube for higher mechanical strength. The thermal shields and their cooling tubes were annealed in air environment to improve the thermal radiation emissivity on the surface. Surface of cryo-panel was electro-polished to minimize the thermal radiation heat load. The in-vessel cryo-pump was pre-assembled on a test bed in 180 degree segment base. The leak test was carried out after the thermal shock between room temperature to LN2 one before installing them into vacuum vessel. Two segments were welded together in the vacuum vessel and final leak test was performed after the thermal shock. Commissioning of the in-vessel cryo-pump was carried out using a temporary liquid helium supply system.

  11. The Making of History's Greatest Star Map

    CERN Document Server

    Perryman, Michael

    2010-01-01

    From prehistoric times, mankind has looked up at the night sky, and puzzled at the changing positions of the stars. How far away they are is a question that has confounded scientists for centuries. Over the last few hundred years, many scientific careers – and considerable resources – have been devoted to measuring their positions and motions with ever increasing accuracy. And in the last two decades of the 20th century, the European Space Agency developed and launched the Hipparcos satellite, around which this account revolves, to carry out these exacting measurements from space. What has prompted these remarkable developments? Why have governments been persuaded to fund them? What are scientists learning from astronomy's equivalent of the Human Genome Project? This book traces the subject's history, explains why such enormous efforts are considered worthwhile, and interweaves these with a first-hand insight into the Hipparcos project, and how big science is conducted at an international level. The invol...

  12. Vessel eddy current characteristics in SST-1 tokamak

    Energy Technology Data Exchange (ETDEWEB)

    Jana, Subrata; Pradhan, Subrata, E-mail: pradhan@ipr.res.in; Dhongde, Jasraj; Masand, Harish

    2016-11-15

    Highlights: • Eddy current distribution in the SST-1 vacuum vessel. • Circuit model analysis of eddy current. • A comparison of the field lines with and without the plasma column in identical conditions. • The influence of eddy current in magnetic NULL dynamics. - Abstract: Eddy current distribution in the vacuum vessel of the Steady state superconducting (SST-1) tokamak has been determined from the experimental data obtained using an array of internal voltage loops (flux loop) installed inside the vacuum vessel. A simple circuit model has been employed. The model takes into account the geometric and constructional features of SST-1 vacuum vessel. SST-1 vacuum vessel is a modified ‘D’ shaped vessel having major axis of 1.285 m and minor axis of 0.81 m and has been manufactured from non-magnetic stainless steel. The Plasma facing components installed inside the vacuum vessel are graphite blocks mounted on Copper Chromium Zirconium (CuCrZr) heat sink plates on inconel supports. During discharge of the central solenoid, eddy currents get generated in the vacuum vessel and passive supports on it. These eddy currents influence the early magnetic NULL dynamics and plasma break-down and start-up characteristics. The computed results obtained from the model have been benchmarked against experimental data obtained in large number of SST-1 plasma shots. The results are in good agreement. Once bench marked, the calculated eddy current based on flux loop signal and circuit equation model has been extended to the reconstruction of the overall B- field contours of SST-1 tokamak in the vessel region. A comparison of the field lines with and without the plasma column in identical conditions of the central solenoid and equilibrium field profiles has also been done with an aim to quantify the diagnostics responses in vacuum shots.

  13. Foundamental characteristics of layered pressure vessel

    International Nuclear Information System (INIS)

    Moriwaki, Yoshikazu; Fugino, Masayuki; Shimizu, Yasuhiro; Nakamura, Takeshi

    1978-01-01

    Pressure vessels become larger and the working pressure become higher with the remarkable development of petroleum, chemical, thermal power generation and atomic energy industries. Multi-layered pressure vessels can be manufactured cheaply without large installations, and large wall thickness can be made, therefore they are suitable for large pressure vessels. The stress and deformation behaviors of such vessels are very complex because of the effect of frictional force working between layers. In this study, the phenomena arising in multiple layers and the difference as compared with single wall were studied fundamentally as one step for analyzing multi-layered pressure vessels as a whole. Finite element technique was employed as the analyzing method, and the behavior of multiple layers was analyzed, regarding it as multiple contact problem. The behavior of multiple layers seems to appear conspicuously in case of bending load, therefore the basic characteristics regarding bending were examined. The evaluation of interfacial stiffness was carried out by experiment. The computer program for analyzing multiple contact problem was developed. In order to examine the validity of the program, comparison with the analytical solution heretofore and the result of calculation by finite element technique was carried out. Moreover, the experimental proof with multi-layered models was made. The frictional force between layers hardly contributes to the stiffness. (Kako, I.)

  14. 46 CFR 115.812 - Pressure vessels and boilers.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 4 2010-10-01 2010-10-01 false Pressure vessels and boilers. 115.812 Section 115.812... CERTIFICATION Material Inspections § 115.812 Pressure vessels and boilers. (a) Pressure vessels must be tested... testing requirements for boilers are contained in § 61.05 in subchapter F of this chapter. [CGD 85-080, 61...

  15. Does bipolar electrocoagulation time affect vessel weld strength?

    Science.gov (United States)

    Harrison, J D; Morris, D L

    1991-01-01

    The value of the bipolar electrocoagulator in the haemostasis of bleeding ulcers is controversial. We have therefore investigated the effect of different coagulation times on vessel weld strength achieved by the bipolar device. Welds were then made in vessels of known diameter using a standard 10F endoscopic haemostatic probe at coagulation times of two and 20 seconds. The intravascular temperature achieved at each time was measured. Vessel weld strength achieved by bipolar electrocoagulation was much greater at 20 seconds (approximately twice that at two seconds) and was highly significantly greater at all vessel diameters. There was a gradual reduction in weld strength with increasing vessel diameter, an effect that was seen for both two and 20 seconds of electrocoagulation. Intravascular temperature was significantly higher at 20 seconds than at two seconds. We conclude that vessel weld strength is related to coagulation time and that any future studies comparing the bipolar electrocoagulator with other haemostatic devices should use longer periods of bipolar electrocoagulation and record the coagulation time in order to optimise the clinical value of the device. PMID:1864540

  16. An interior vessel viewing system for DIII-D

    International Nuclear Information System (INIS)

    Senior, R.

    1989-11-01

    It was anticipated that there could be damage to the interior walls of the vacuum vessel during operations of the DIII-D tokamak. A method of viewing the inside of the vessel from the outside was required, that would allow the interior walls to be inspected visually for damage and to locate any debris resulting from operations. A miniature closed circuit television color camera system was developed which could be inserted into one of several ports of the vessel during a 'clean' vent, i.e., vented to inert gas. The system has pan, tilt and zoom capability and carries its own lighting. The use of this system allows a quick assessment of the condition of the vessel to be made under 'clean' vent conditions. This precludes the need for the permit process and manned entry into the vessel which would allow air inside the vessel. A permanent record of the inspection can then be made on video tape. The design and configuration of this camera system is presented and its use as a diagnostic tool discussed. 2 refs., 5 figs

  17. Integrity of PWR pressure vessels during overcooling accidents

    International Nuclear Information System (INIS)

    Cheverton, R.D.; Iskander, S.K.; Whitman, G.D.

    1982-01-01

    The reactor pressure vessel in a pressurized water reactor is normally subjected to temperatures and pressures that preclude propagation of sharp, crack-like defects that might exist in the wall of the vessel. However, there is a class of postulated accidents, referred to as overcooling accidents, that can subject the pressure vessel to severe thermal shock while the pressure is substantial. As a result of such accidents vessels containing high concentrations of copper and nickel, which enhance radiation embrittlement, may possess a potential for extensive propagation of preexistent inner surface flaws prior to the vessel's normal end of life. For the purpose of evaluating this problem a state-of-the-art fracture mechanics model was developed and has been used for conducting parametric analyses and for calculating several recorded PWR transients. Results of the latter analysis indicate that there may be some vessels that have a potential for failure today if subjected to a Rancho Seco (1978) or TMI-2 (1979) type transient. However, the calculational model may be excessively conservative, and this possibility is under investigation

  18. Integrity of PWR pressure vessels during overcooling accidents

    International Nuclear Information System (INIS)

    Cheverton, R.D.; Iskander, S.K.; Whitman, G.D.

    1982-01-01

    The reactor pressure vessel in a pressurized water reactor is normally subjected to temperatures and pressures that preclude propagation of sharp, crack-like defects that might exist in the wall of the vessel. However, there is a class of postulated accidents, referred to as overcooling accidents, that can subject the pressure vessel to severe thermal shock while the pressure is substantial. As a result of such accidents, vessels containing high concentrations of copper and nickel, which enhance radiation embrittlement, may possess a potential for extensive propagation of preexistent inner surface flaws prior to the vessel's normal end of life. A state-of-the-art fracture-mechanics model was developed and has been used for conducting parametric analyses and for calculating several recorded PWR transients. Results of the latter analysis indicate that there may be some vessels that have a potential for failure in a few years if subjected to a Rancho Seco-type transient. However, the calculational model may be excessively conservative, and this possibility is under investigation

  19. Depressurization as a means of leak checking large vacuum vessels

    International Nuclear Information System (INIS)

    Callis, R.W.; Langhorn, A.; Petersen, P.I.; Ward, C.; Wesley, J.

    1985-01-01

    A common problem associated with large vacuum vessels used in magnetic confinement fusion experiments is that leak checking is hampered by the inaccessibility to most of the vacuum vessel surface. This inaccessibility is caused by the close proximity of magnetic coils, diagnostics and, for those vessels that are baked, the need to completely surround the vessel with a thermal insulation blanket. These obstructions reduce the effectiveness of the standard leak checking method of using a mass spectrometer and spraying a search gas such as helium on the vessel exterior. Even when the presence of helium is detected, its entry point into the vessel cannot always be pinpointed. This paper will describe a method of overcoming this problem. By slightly depressurizing the vessel, an influx of helium through the leak is created. The leak site can then be identified by personnel within the vessel using standard sniffing procedures. There are two conditions which make this method of leak checking practical. First, the vessel need only be depressurized 2 psi, thus allowing personnel inside to perform the sniffing operation. Second, the sniffing probe used (Leybold--Heraus ''Quick Test'') could detect a change in helium concentration as small as 100 ppb, which allows for faster scanning of the vessel inferior. Use of this technique to find an elusive 10 -3 Torrxl/s leak in the Doublet III tokamak vacuum vessel will be presented

  20. 46 CFR 111.105-35 - Vessels carrying coal.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 4 2010-10-01 2010-10-01 false Vessels carrying coal. 111.105-35 Section 111.105-35...-GENERAL REQUIREMENTS Hazardous Locations § 111.105-35 Vessels carrying coal. (a) The following are Class II, Division 1, (Zone 10 or Z) locations on a vessel that carries coal: (1) The interior of each coal...

  1. Vessel Sewage Discharges

    Science.gov (United States)

    Vessel sewage discharges are regulated under Section 312 of the Clean Water Act, which is jointly implemented by the EPA and Coast Guard. This homepage links to information on marine sanitation devices and no discharge zones.

  2. Lightweight submersed 'Walking' NDE manipulators for PWR and BWR vessel weld inspection

    International Nuclear Information System (INIS)

    Saernmark, Ivan; Lenz, Herbert

    2008-01-01

    Three new manipulators developed by WesDyne TRC in Sweden have under the year 2007 performed three very successful inspections in the PWR reactor Ringhals 3 and the BWR reactors Ringhals 1 and Oskarshamn 1. The manipulator systems can be used to perform inspection of circumferential and vertical welds on the reactor pressure vessel, the core shroud, core shroud support in BWR reactors or vessel and core barrel welds in PWR reactors. Most other flat or curved surfaces can be inspected using the new concept through relatively simple mechanical reconfigurations of system modules. The first inspection was performed on the R3 PWR core barrel in June 2007 with a very good result. This Manipulator is designed for access in very narrow gaps and for the type of core barrels with a shield covering the whole area of the perimeter. The manipulator is attached to the inspection area by means of a new unique suction cup system. The current manipulators consist of a curved horizontal beam, with radius similar to the reactor vessel, and a straight vertical beam, forming a T-shaped structure. By alternating the application of suction cup pairs on the horizontal beam and the vertical beam and by driving the scanning motors, the manipulator performs an incremental translational movement upwards/downwards or from side to side. The principles of this system give a well defined and stable platform for global and local positioning accuracy. A combination of advanced sensor solutions provides accurate position information in the absence of other physical reference objects. The system is controlled by the new WesDyne TRC Motor Control Panel and software, the MCP is specifically designed for remote control of submersed manipulators using techniques for cable reduction

  3. Analysis of the microstructural evolution of the damage by neutron irradiation in the pressure vessel of a nuclear power reactor BWR

    International Nuclear Information System (INIS)

    Moranchel y R, M.

    2012-01-01

    chemical of steel components concentration profiles after irradiated, among others. MCNPX version 2005 and SRIM-2011 there are the computer codes used in the Monte Carlo simulation for analyzing the vessel damage theoretically due to penetration and the radiation transport of the neutrons coming of the reactor core. With MCNPX was determined the profile of neutrons penetration, the photons flux, electrons, alphas, protons deuterons, etc, in the interior of the vessel, the profile of energy deposited by all particles generated in the interaction of neutrons with the steel atomic structures, the profile displacement, the regions of greater damage as well as the total damage over the life of the reactor, among many others. With SRIM-2011 was determined the atomic displacements profile of each atomic species in the steel (Fe, Ni, Mn, Cr, Mo, V, Cu, etc.), the energy deposited profile by each atomic species, the profile of damage in the interior of the vessel, the greater damage region as well as the total damage throughout the life of the nuclear reactor. The theoretical results have enabled understanding of physical phenomena occurring in the crystalline structure of steel, by influence of irradiation neutron to determine the region of greatest possible damage in the crock. The theoretical results were compared with experimental results and those of international references in this field of research. Among other results, is determined that the region of greater damage occurs in the first millimeter of depth of the vessel and confirms its full integrity after eight years of neutron irradiation and to not less than 60 years of life with a thickness of 12 cm. (Author)

  4. The JET high temperature in-vessel inspection system

    International Nuclear Information System (INIS)

    Businaro, T.; Cusack, R.; Calbiati, L.; Raimondi, T.

    1989-01-01

    The JET In-vessel Inspection System (IVIS) has been enhanced for operation under the following nominal conditions: vacuum vessel at 350 degC; vacuum vessel evacuated (∼10 -9 mbar); radiation dose during D-T phase 10 rads. The target resolution of the pictures is 2 mm at 5 m distance and tests on radiation resistance of the IVIS system are being carried out. Since June 1988, the new system is installed in the JET machine and the first inspections of the intire vessel at 250 degC have been satisfactory done. (author). 3 refs.; 6 figs.; 1 tab

  5. Investigation of vessel visibility of iterative reconstruction method in coronary computed tomography angiography using simulated vessel phantom

    International Nuclear Information System (INIS)

    Inoue, Takeshi; Uto, Fumiaki; Ichikawa, Katsuhiro; Hara, Takanori; Urikura, Atsushi; Hoshino, Takashi; Miura, Youhei; Terakawa, Syouichi

    2012-01-01

    Iterative reconstruction methods can reduce the noise of computed tomography (CT) images, which are expected to contribute to the reduction of patient dose CT examinations. The purpose of this study was to investigate impact of an iterative reconstruction method (iDose 4 , Philips Healthcare) on vessel visibility in coronary CT angiography (CTA) by using phantom studies. A simulated phantom was scanned by a CT system (iCT, Philips Healthcare), and the axial images were reconstructed by filtered back projection (FBP) and given a level of 1 to 7 (L1-L7) of the iterative reconstruction (IR). The vessel visibility was evaluated by a quantitative analysis using profiles across a 1.5-mm diameter simulated vessel as well as visual evaluation for multi planar reformation (MPR) images and volume rendering (VR) images in terms of the normalized-rank method with analysis of variance. The peak CT value of the profiles decreased with IR level and full width at half maximum of the profile also decreased with the IR level. For normalized-rank method, there was no statistical difference between FBP and L1 (20% dose reduction) for both MPR and VR images. The IR levels higher than L1 sacrificed the spatial resolution for the 1.5-mm simulated vessel, and their visual vessel visibilities were significantly inferior to that of the FBP. (author)

  6. Apparatus for carrying out ultrasonic inspection of pressure vessels

    International Nuclear Information System (INIS)

    Dent, K.H.; Greenhalgh, F.G.

    1975-01-01

    An apparatus is described for moving an ultrasonic scanning mechanism over the interior surface of a pressure vessel and comprising a mast for supporting the scanning mechanism inside the vessel and a carriage for traversing the mast within the vessel, the mast being pivotably secured to the carriage so that when the ultrasonic scanning mechanism contacts the interior surface of the pressure vessel the mast is caused to pivot. (auth)

  7. Advanced in-vessel retention design for next generation risk management

    Energy Technology Data Exchange (ETDEWEB)

    Suh, Kune Y; Hwang, Il Soon [Seoul National University, Seoul (Korea, Republic of)

    1998-12-31

    In the TMI-2 accident, approximately twenty (20) tons of molten core material drained into the lower plenum. Early advanced light water reactor (LWR) designs assumed a lower head failure and incorporated various measures for ex-vessel accident mitigation. However,one of the major findings from the TMI-2 Vessel Investigation Project was that one part of the reactor lower head wall estimated to have attained a temperature of 1100 deg C for about 30 minutes has seemingly experienced a comparatively rapid cooldown with no major threat to the vessel integrity. In this regard, recent empirical and analytical studies have shifted interests to such in-vessel retention designs or strategies as reactor cavity flooding, in-vessel flooding and engineered gap cooling of the vessel. Accurate thermohydrodynamic and creep deformation modeling and rupture prediction are the key to the success in developing practically useful in-vessel accident/risk management strategies. As an advanced in-vessel design concept, this work presents the COrium Attack Syndrome Immunization Structures (COASIS) that are being developed as prospective in-vessel retention devices for a next-generation LWR in concert with existing ex-vessel management measures. Both the engineered gap structures in-vessel (COASISI) and ex-vessel (COASISO) are demonstrated to maintain effective heat transfer geometry during molten core debris attack when applied to the Korean Standard Nuclear Power Plant (KSNPP) reactor. The likelihood of lower head creep rupture during a severe accident is found to be significantly suppressed by the COASIS options. 15 refs., 5 figs., 1 tab. (Author)

  8. Advanced in-vessel retention design for next generation risk management

    Energy Technology Data Exchange (ETDEWEB)

    Suh, Kune Y.; Hwang, Il Soon [Seoul National University, Seoul (Korea, Republic of)

    1997-12-31

    In the TMI-2 accident, approximately twenty (20) tons of molten core material drained into the lower plenum. Early advanced light water reactor (LWR) designs assumed a lower head failure and incorporated various measures for ex-vessel accident mitigation. However,one of the major findings from the TMI-2 Vessel Investigation Project was that one part of the reactor lower head wall estimated to have attained a temperature of 1100 deg C for about 30 minutes has seemingly experienced a comparatively rapid cooldown with no major threat to the vessel integrity. In this regard, recent empirical and analytical studies have shifted interests to such in-vessel retention designs or strategies as reactor cavity flooding, in-vessel flooding and engineered gap cooling of the vessel. Accurate thermohydrodynamic and creep deformation modeling and rupture prediction are the key to the success in developing practically useful in-vessel accident/risk management strategies. As an advanced in-vessel design concept, this work presents the COrium Attack Syndrome Immunization Structures (COASIS) that are being developed as prospective in-vessel retention devices for a next-generation LWR in concert with existing ex-vessel management measures. Both the engineered gap structures in-vessel (COASISI) and ex-vessel (COASISO) are demonstrated to maintain effective heat transfer geometry during molten core debris attack when applied to the Korean Standard Nuclear Power Plant (KSNPP) reactor. The likelihood of lower head creep rupture during a severe accident is found to be significantly suppressed by the COASIS options. 15 refs., 5 figs., 1 tab. (Author)

  9. Evaluation of In-Vessel Corium Retention under a Severe Accident

    Energy Technology Data Exchange (ETDEWEB)

    Park, Rae-Joon; Kang, Kyung-Ho; Ha, Kwang-Soon; Kim, Jong-Tae; Koo, Kil-Mo; Cho, Young-Ro; Hong, Seong-Wan; Kim, Sang-Baik; Kim, Hee-Dong

    2008-02-15

    The current study on In-Vessel corium Retention and its application activities to the actual nuclear power plant have been reviewed and discussed in this study. Severe accident sequence which determines an initial condition of the IVR has been evaluated and late phase melt progression, heat transfer on the outer reactor vessel, and in-vessel corium cooling mechanism have been estimated in detail. During the high pressure sequence of the reactor coolant system, a natural circulation flow of the hot steam leads to a failure of the pressurizer surge line before the reactor vessel failure, which leads to a rapid decrease of the reactor coolant system pressure. The results of RASPLAV/MASCA study by OECD/NEA have shown that a melt stratification has occurred in the lower plenum of the reactor vessel. In particular, laver inversion has occurred, which is that a high density of the metal melt moves to the lower part of the oxidic melt layer. A method of heat transfer enhancement on the outer reactor vessel is an optimal design of the reactor vessel insulation for an increase of the natural circulation flow between the outer reactor vessel and the its insulation, and an increase of the critical Heat flux on the outer reactor vessel by using various method, such as Nono fluid, coated reactor vessel, and so on. An increase method of the in-vessel melt cooling is a development of the In-vessel core catcher and a decrease of focusing effect in the metal layer.

  10. ROI DETECTION AND VESSEL SEGMENTATION IN RETINAL IMAGE

    Directory of Open Access Journals (Sweden)

    F. Sabaz

    2017-11-01

    Full Text Available Diabetes disrupts work by affecting the structure of the eye and afterwards leads to loss of vision. Depending on the stage of disease that called diabetic retinopathy, there are sudden loss of vision and blurred vision problems. Automated detection of vessels in retinal images is a useful study to diagnose eye diseases, disease classification and other clinical trials. The shape and structure of the vessels give information about the severity of the disease and the stage of the disease. Automatic and fast detection of vessels allows for a quick diagnosis of the disease and the treatment process to start shortly. ROI detection and vessel extraction methods for retinal image are mentioned in this study. It is shown that the Frangi filter used in image processing can be successfully used in detection and extraction of vessels.

  11. Emergency venting of pressure vessels

    International Nuclear Information System (INIS)

    Steinkamp, H.

    1995-01-01

    With the numerical codes developed for safety analysis the venting of steam vessel can be simulated. ATHLET especially is able to predict the void fraction depending on the vessel height. Although these codes contain a one-dimensional model they allow the description of complex geometries due to the detailed nodalization of the considered apparatus. In chemical reactors, however, the venting process is not only influenced by the flashing behaviour but additionally by the running chemical reaction in the vessel. Therefore the codes used for modelling have to consider the kinetics of the chemical reaction. Further multi-component systems and dissolving processes have to be regarded. In order to preduct the fluid- and thermodynamic process it could be helpful to use 3-dimensional codes in combination with the one-dimensional codes as used in nuclear industry to get a more detailed describtion of the running processes. (orig./HP)

  12. Confinement Vessel Assay System: Design and Implementation Report

    International Nuclear Information System (INIS)

    Frame, Katherine C.; Bourne, Mark M.; Crooks, William J.; Evans, Louise; Mayo, Douglas R.; Gomez, Cipriano D.; Miko, David K.; Salazar, William R.; Stange, Sy; Vigil, Georgiana M.

    2012-01-01

    Los Alamos National Laboratory has a number of spherical confinement vessels remaining from tests involving nuclear materials. These vessels have an inner diameter of 6 feet with 1- to 2-inch thick steel walls. The goal of the Confinement Vessel Disposition (CVD) project is to remove debris and reduce contamination inside the vessels. We have developed a neutron assay system for the purposes of Materials Control and Accountability (MC and A) measurements of the vessel prior to and after cleanout. We present our approach to confronting the challenges in designing, building, and testing such a system. The system was designed to meet a set of functional and operational requirements. A Monte Carlo model was developed to aid in optimizing the detector design as well as to predict the systematic uncertainty associated with confinement vessel measurements. Initial testing was performed to optimize and determine various measurement parameters, and then the system was characterized using 252 Cf placed a various locations throughout the measurement system. Measurements were also performed with a 252 Cf source placed inside of small steel and HDPE shells to study the effect of moderation. These measurements compare favorably with their MCNPX model equivalent, making us confident that we can rely on the Monte Carlo simulation to predict the systematic uncertainty due to variations in response to material that may be localized at different points within a vessel.

  13. Ultrasonographic Examination of Some Vessels in Dogs and the Characteristics of Blood Flow in These Vessels

    Directory of Open Access Journals (Sweden)

    Figurová M.

    2017-12-01

    Full Text Available The examination by Doppler ultrasonography provides haemodynamic information about blood flow velocity in a respective vessel. It specifies high- and lowresistance flow patterns. The aim of our study was to record the flow in a. carotis communis, a. femoralis and aa. renales in 16 adult clinically healthy dogs of small and medium size; characterize the types of vessels and also determine the pulsatility index (PI and the resistive index (RI of these vessels. The a. femoralis is a high-resistance vessel with a pronounced three-peak waveform. The aa. renales gives a typical picture of a low-resistance flow pattern. The characteristics of a. carotis communis involves different images of its branches a. carotis interna and a. carotis externa. In the investigated groups we observed a medium degree of pulsatility (atypical highresistance flow pattern with an absence of reverse flow. The mean measured values of indices for a. carotis communis were: left side PI 1.824 and RI 0.742; right side PI 1.891 and RI 0.746, and for aa. renales: PI 1.366 ± 0.04 and RI 0.684 ± 0.05.

  14. Muscle-splitting approach to superior and inferior gluteal vessels: versatile source of recipient vessels for free-tissue transfer to sacral, gluteal, and ischial regions.

    Science.gov (United States)

    Park, S

    2000-07-01

    The superior gluteal vessel has been reported as a recipient in free-tissue transfer for the coverage of complex soft-tissue defects in the lumbosacral region, where a suitable recipient vessel is difficult to find. The characteristics of proximity, vessel caliber, and constancy make the superior gluteal vessel preferable to previously reported recipient vessels. However, there are technical difficulties in microsurgery (e.g., short pedicle length and deep location) and muscle injury (transection of the muscle) associated with use of the superior gluteal vessel. The purpose of this article is to present a modification of an approach to the gluteal vessel to alleviate technical difficulties and minimize muscle injury. From August of 1997 to January of 1999, six patients received microvascular transfer of the latissimus dorsi muscle or myocutaneous flap to the sacral (4) and ischial (2) regions. The causes of defects were tumor (1), trauma (1), and pressure sores (4). A muscle-splitting approach was used on the superior gluteal vessel and was later applied to the inferior gluteal vessel. The gluteus maximus muscle was split as needed in the direction of its fibers, and the perforators were dissected down to the superior or inferior gluteal artery and vein deep into the muscle. The follow-up period ranged from 6 to 22 months, and all of the flaps survived with complete recovery of the lesion. The major drawbacks of using the superior and inferior gluteal vessels can be overcome with the muscle-splitting approach, which provides increased accessibility and additional length to the vascular pedicle while causing minimal injury to the muscle itself. It also proves to be an easy, safe, and reliable method of dissection. When free-tissue transfer to sacral, gluteal, and ischial regions is indicated, the muscle-splitting approach to the superior and inferior gluteal vessels is a recommended option in the selection of a recipient vessel.

  15. [Large vessels vasculopathy in systemic sclerosis].

    Science.gov (United States)

    Tejera Segura, Beatriz; Ferraz-Amaro, Iván

    2015-12-07

    Vasculopathy in systemic sclerosis is a severe, in many cases irreversible, manifestation that can lead to amputation. While the classical clinical manifestations of the disease have to do with the involvement of microcirculation, proximal vessels of upper and lower limbs can also be affected. This involvement of large vessels may be related to systemic sclerosis, vasculitis or atherosclerotic, and the differential diagnosis is not easy. To conduct a proper and early diagnosis, it is essential to start prompt appropriate treatment. In this review, we examine the involvement of large vessels in scleroderma, an understudied manifestation with important prognostic and therapeutic implications. Copyright © 2015 Elsevier España, S.L.U. All rights reserved.

  16. Reactor vessel using metal oxide ceramic membranes

    Science.gov (United States)

    Anderson, Marc A.; Zeltner, Walter A.

    1992-08-11

    A reaction vessel for use in photoelectrochemical reactions includes as its reactive surface a metal oxide porous ceramic membrane of a catalytic metal such as titanium. The reaction vessel includes a light source and a counter electrode. A provision for applying an electrical bias between the membrane and the counter electrode permits the Fermi levels of potential reaction to be favored so that certain reactions may be favored in the vessel. The electrical biasing is also useful for the cleaning of the catalytic membrane.

  17. Development and control towards a parallel water hydraulic weld/cut robot for machining processes in ITER vacuum vessel

    International Nuclear Information System (INIS)

    Wu Huapeng; Handroos, Heikki; Pessi, Pekka; Kilkki, Juha; Jones, Lawrence

    2005-01-01

    This paper presents a special robot, able to carry out welding and machining processes from inside the ITER vacuum vessel (VV), consisting of a five degree-of-freedom parallel mechanism, mounted on a carriage driven by two electric motors on a rack. The kinematic design of the robot has been optimised for ITER access and a hydraulically actuated pre-prototype built. A hybrid controller is designed for the robot, including position, speed and pressure feedback loops to achieve high accuracy and high dynamic performances. Finally, the experimental tests are given and discussed

  18. In-service inspection robot for PFBR main vessel- concept

    Energy Technology Data Exchange (ETDEWEB)

    Rajendran, S; Ramakumar, M S [Bhabha Atomic Research Centre, Mumbai (India). Div. of Remote Handling and Robotics

    1994-12-31

    In-service inspection (ISI) of critical components in a nuclear reactor is one of the foremost and important tasks which reveals the state of health of the system, thereby ensuring the safety of the plant, personnel and environment. Prototype Fast Breeder Reactor (PFBR) is designed as a pool type reactor. A safety vessel is provided in the design which envelopes the main reactor vessel. The ISI of the main vessel is mandatory and will be carried out by a robot which will operate on this annular gap. The design of the robot is such that it can crawl around the vessel and into the gap at the bottom of the vessel relying on friction grip. The mobile robot will carry a CCTV camera and the inspection technique packages into the interspace, position and orient these to carry out the ISI of the main vessel. The paper discusses about the design features of the robot including the gripping mechanism and the crawling sequence to perform ISI of the reactor vessel. 3 figs.

  19. In-service inspection robot for PFBR main vessel- concept

    International Nuclear Information System (INIS)

    Rajendran, S.; Ramakumar, M.S.

    1994-01-01

    In-service inspection (ISI) of critical components in a nuclear reactor is one of the foremost and important tasks which reveals the state of health of the system, thereby ensuring the safety of the plant, personnel and environment. Prototype Fast Breeder Reactor (PFBR) is designed as a pool type reactor. A safety vessel is provided in the design which envelopes the main reactor vessel. The ISI of the main vessel is mandatory and will be carried out by a robot which will operate on this annular gap. The design of the robot is such that it can crawl around the vessel and into the gap at the bottom of the vessel relying on friction grip. The mobile robot will carry a CCTV camera and the inspection technique packages into the interspace, position and orient these to carry out the ISI of the main vessel. The paper discusses about the design features of the robot including the gripping mechanism and the crawling sequence to perform ISI of the reactor vessel. 3 figs

  20. Distribution of the In-Vessel Diagnostics in ITER Tokamak

    Energy Technology Data Exchange (ETDEWEB)

    González, Jorge, E-mail: Jorge.Gonzalez@iter.org [Rüecker Lypsa, Carretera del Prat, 65, Cornellá de Llobregat (Spain); Clough, Matthew; Martin, Alex; Woods, Nick; Suarez, Alejandro [ITER Organization, Route de Vinon sur Verdon-CS 90 046 13067 Saint Paul Lez Durance (France); Martinez, Gonzalo [Technical University Of Catalonia (UPC), Barcelona-Tech, Barcelona (Spain); Stefan, Gicquel; Yunxing, Ma [ITER Organization, Route de Vinon sur Verdon-CS 90 046 13067 Saint Paul Lez Durance (France)

    2017-01-15

    The ITER In-Vessel Diagnostics have been distributed around the In-Vessel shell to understand burning plasma physics and assist in machine operation. Each diagnostics component has its own requirements, constraints, and even exclusion among them for the highly complex In-Vessel environment. The size of the plasma, the requirement to be able to align the blanket system to the magnetic centre of the machine, the cooling requirements of the blanket system and the size of the pressure vessel itself all add to the difficulties of integrating these systems into the remaining space available. The available space for the cables inside the special trays (in-Vessel looms) is another constraint to allocate In-Vessel electrical sensors. Besides this, there are issues with the Assembly sequences and surface & volumetric neutron heating considerations that have imposed several additional restrictions.

  1. Predicting Vessel Trajectories from Ais Data Using R

    Science.gov (United States)

    2017-06-01

    Source: Hampton (2009). A vessel operator with AIS is able to get useful information about the other vessels in the area by selecting a vessel icon ...random forest model on our computer. All calculations are done on a MacBook-Pro with 2.7GHz quad-core Intel Core i7, and 16GB of memory . H2O allows us

  2. Accuracy of hepatocellular carcinoma detection on multidetector CT in a transplant liver population with explant liver correlation

    International Nuclear Information System (INIS)

    Addley, H.C.; Griffin, N.; Shaw, A.S.; Mannelli, L.; Parker, R.A.; Aitken, S.; Wood, H.; Davies, S.; Alexander, G.J.; Lomas, D.J.

    2011-01-01

    Aim: To evaluate the diagnostic accuracy of multidetector computed tomography (MDCT) for hepatocellular carcinoma (HCC) in cirrhotic patients undergoing liver transplantation. Secondary aims were to examine the effect of radiologist experience and lesion size on diagnostic accuracy. Materials and methods: Thirty-nine patients (72% male with a mean age of 56.5 years) underwent liver transplantation following preoperative triple-phase MDCT examination of the liver. MDCT examinations were retrospectively independently reviewed by three radiologists for the presence and location of suspected HCCs, with the diagnostic confidence recorded using a five-point confidence scale. MDCT examinations were compared with explant specimens for histopathological correlation. Results: Histopathological results demonstrated 46 HCCs in 29 of the 39 patients. Analysis demonstrated a sensitivity of 65-75% and specificity of 47-88% for detection of HCC lesions. The sensitivity dropped to 48-57% for lesions of size ≤20 mm. As the diagnostic confidence increased, there was a further decrease in the sensitivity (4-26%). The radiologist with the greatest number of years experience was found to have a significantly higher accuracy of detection of HCC lesions compared with the least experienced radiologist. Conclusion: Larger lesion size of HCC and greater number of years experience of the radiologist resulted in significantly higher accuracy of HCC lesion detection. The overall sensitivity and specificity results for MDCT detection of HCC are comparable to previous helical CT imaging.

  3. Inspection apparatus for a vessel made of magnetic metal

    International Nuclear Information System (INIS)

    Clark, J.P.; Foster, A.C.; Smith, T.D.

    1976-01-01

    Previous systems intended for in-situ inspection of the pressure vessels of nuclear reactors are of uneasy use on encumbered surfaces. Said invention relates to a remote-control device for inspecting vessel walls. It comprises a conveyor able to be propelled, possibly around obstacles, towards any place inside the vessel; said vehicle is provided with magnetic wheels driven by an electric motor and separately controlled. The conveyor is accurately located on the vessel by using an acoustic device involving a triangular method, and consisting in an acoustic signal emitter mounted on the conveyor and at least three receiving transducers mounted on the vessel wall [fr

  4. Study of evaluation methods for in-vessel corium retention through external vessel cooling and safety of reactor cavity

    Energy Technology Data Exchange (ETDEWEB)

    Huh, Hoon; Chang, Soon Heung; Kim, Soo Hyung; Kim, Kee Poong; Lee, Hyoung Wook; Jang, Kwang Keol; Jeong, Yong Hoon; Kim, Sang Jin; Lee, Seong Jin [Korea Advanced Institute of Science and Technology, Taejon (Korea, Republic of); Park, Jae Hong [Korea Institute of Nuclear Safety, Taejon (Korea, Republic of)

    2001-03-15

    In this work, assessment system for methodology for reactor pressure vessel integrity is developed. Assessment system is make up of severe accident assessment code which can calculate the conditions of plant and structural analysis code which can assess the integrity of reactor vessel using given plant conditions. An assessment of cavity flooding using containment spray system has been done. As a result, by the containment spray, cavity can be flooded successfully and CCI can be reduced. The technical backgrounds for external vessel cooling and corium cooling on the cavity are summarized and provided in this report.

  5. Study of evaluation methods for in-vessel corium retention through external vessel cooling and safety of reactor cavity

    International Nuclear Information System (INIS)

    Huh, Hoon; Chang, Soon Heung; Kim, Soo Hyung; Kim, Kee Poong; Lee, Hyoung Wook; Jang, Kwang Keol; Jeong, Yong Hoon; Kim, Sang Jin; Lee, Seong Jin; Park, Jae Hong

    2001-03-01

    In this work, assessment system for methodology for reactor pressure vessel integrity is developed. Assessment system is make up of severe accident assessment code which can calculate the conditions of plant and structural analysis code which can assess the integrity of reactor vessel using given plant conditions. An assessment of cavity flooding using containment spray system has been done. As a result, by the containment spray, cavity can be flooded successfully and CCI can be reduced. The technical backgrounds for external vessel cooling and corium cooling on the cavity are summarized and provided in this report

  6. Application of an Autonomous/Unmanned Survey Vessel (ASV/USV in Bathymetric Measurements

    Directory of Open Access Journals (Sweden)

    Specht Cezary

    2017-09-01

    Full Text Available The accuracy of bathymetric maps, especially in the coastal zone, is very important from the point of view of safety of navigation and transport. Due to the continuous change in shape of the seabed, these maps are fast becoming outdated for precise navigation. Therefore, it is necessary to perform periodical bathymetric measurements to keep them updated on a current basis. At present, none of the institutions in Poland (maritime offices, Hydrographic Office of the Polish Navy which are responsible for implementation of this type of measurements has at their disposal a hydrographic vessel capable of carrying out measurements for shallow waters (at depths below 1 m. This results in emergence of large areas for which no measurement data have been obtained and, consequently, the maps in the coastal zones are rather unreliable.

  7. Head spray nozzle in reactor pressure vessel

    International Nuclear Information System (INIS)

    Hatano, Shun-ichi.

    1990-01-01

    In a reactor pressure vessel of a BWR type reactor, a head spray nozzle is used for cooling the head of the pressure vessel and, in view of the thermal stresses, it is desirable that cooling is applied as uniformly as possible. A conventional head spray is constituted by combining full cone type nozzles. Since the sprayed water is flown down upon water spraying and the sprayed water in the vertical direction is overlapped, the flow rate distribution has a high sharpness to form a shape as having a maximum value near the center and it is difficult to obtain a uniform flow rate distribution in the circumferential direction. Then, in the present invention, flat nozzles each having a spray water cross section of laterally long shape, having less sharpness in the circumferential distribution upon spraying water to the inner wall of the pressure vessel and having a wide angle of water spray are combined, to make the flow rate distribution of spray water uniform in the inner wall of the pressure vessel. Accordingly, the pressure vessel can be cooled uniformly and thermal stresses upon cooling can be decreased. (N.H.)

  8. Unsupervised Retinal Vessel Segmentation Using Combined Filters.

    Directory of Open Access Journals (Sweden)

    Wendeson S Oliveira

    Full Text Available Image segmentation of retinal blood vessels is a process that can help to predict and diagnose cardiovascular related diseases, such as hypertension and diabetes, which are known to affect the retinal blood vessels' appearance. This work proposes an unsupervised method for the segmentation of retinal vessels images using a combined matched filter, Frangi's filter and Gabor Wavelet filter to enhance the images. The combination of these three filters in order to improve the segmentation is the main motivation of this work. We investigate two approaches to perform the filter combination: weighted mean and median ranking. Segmentation methods are tested after the vessel enhancement. Enhanced images with median ranking are segmented using a simple threshold criterion. Two segmentation procedures are applied when considering enhanced retinal images using the weighted mean approach. The first method is based on deformable models and the second uses fuzzy C-means for the image segmentation. The procedure is evaluated using two public image databases, Drive and Stare. The experimental results demonstrate that the proposed methods perform well for vessel segmentation in comparison with state-of-the-art methods.

  9. Trends in Tissue Engineering for Blood Vessels

    Directory of Open Access Journals (Sweden)

    Judee Grace Nemeno-Guanzon

    2012-01-01

    Full Text Available Over the years, cardiovascular diseases continue to increase and affect not only human health but also the economic stability worldwide. The advancement in tissue engineering is contributing a lot in dealing with this immediate need of alleviating human health. Blood vessel diseases are considered as major cardiovascular health problems. Although blood vessel transplantation is the most convenient treatment, it has been delimited due to scarcity of donors and the patient’s conditions. However, tissue-engineered blood vessels are promising alternatives as mode of treatment for blood vessel defects. The purpose of this paper is to show the importance of the advancement on biofabrication technology for treatment of soft tissue defects particularly for vascular tissues. This will also provide an overview and update on the current status of tissue reconstruction especially from autologous stem cells, scaffolds, and scaffold-free cellular transplantable constructs. The discussion of this paper will be focused on the historical view of cardiovascular tissue engineering and stem cell biology. The representative studies featured in this paper are limited within the last decade in order to trace the trend and evolution of techniques for blood vessel tissue engineering.

  10. Target Price Accuracy

    Directory of Open Access Journals (Sweden)

    Alexander G. Kerl

    2011-04-01

    Full Text Available This study analyzes the accuracy of forecasted target prices within analysts’ reports. We compute a measure for target price forecast accuracy that evaluates the ability of analysts to exactly forecast the ex-ante (unknown 12-month stock price. Furthermore, we determine factors that explain this accuracy. Target price accuracy is negatively related to analyst-specific optimism and stock-specific risk (measured by volatility and price-to-book ratio. However, target price accuracy is positively related to the level of detail of each report, company size and the reputation of the investment bank. The potential conflicts of interests between an analyst and a covered company do not bias forecast accuracy.

  11. A Measure of Similarity Between Trajectories of Vessels

    Directory of Open Access Journals (Sweden)

    Le QI

    2016-03-01

    Full Text Available The measurement of similarity between trajectories of vessels is one of the kernel problems that must be addressed to promote the development of maritime intelligent traffic system (ITS. In this study, a new model of trajectory similarity measurement was established to improve the data processing efficiency in dynamic application and to reflect actual sailing behaviors of vessels. In this model, a feature point detection algorithm was proposed to extract feature points, reduce data storage space and save computational resources. A new synthesized distance algorithm was also created to measure the similarity between trajectories by using the extracted feature points. An experiment was conducted to measure the similarity between the real trajectories of vessels. The growth of these trajectories required measurements to be conducted under different voyages. The results show that the similarity measurement between the vessel trajectories is efficient and correct. Comparison of the synthesized distance with the sailing behaviors of vessels proves that results are consistent with actual situations. The experiment results demonstrate the promising application of the proposed model in studying vessel traffic and in supplying reliable data for the development of maritime ITS.

  12. Method of detecting water leakage in radioactive waste containing vessel

    International Nuclear Information System (INIS)

    Ishioka, Hitoshi; Takao, Yoshiaki; Hayakawa, Kiyoshige.

    1989-01-01

    Lower level radioactive wastes formed upon operation of nuclear facilities are processed by underground storage. In this case, a plurality of drum cans packed with radioactive wastes are contained in a vessel and a water soluble dye material is placed at the inside of the vessel. The method of placing the water soluble dye material at the inside of the vessel includes a method of coating the material on the inner surface of the vessel and a method of mixing the material in sands to be filled between each of the drum cans. Then, leakage of water soluble dye material is detected when water intruding from the outside into the vessel is again leached out of the vessel, to detect the water leakage from the inside of the vessel. In this way, it is possible to find a water-invaded vessel before corrosion of the drum can by water intruded into the vessel and leakage of nuclides in the drum can. Accordingly, it is possible to apply treatment such as repair before occurrence of accident and can maintain the safety of radioactive water processing facilities. (I.S.)

  13. Structural Analysis of the NCSX Vacuum Vessel

    International Nuclear Information System (INIS)

    Fred Dahlgren; Art Brooks; Paul Goranson; Mike Cole; Peter Titus

    2004-01-01

    The NCSX (National Compact Stellarator Experiment) vacuum vessel has a rather unique shape being very closely coupled topologically to the three-fold stellarator symmetry of the plasma it contains. This shape does not permit the use of the common forms of pressure vessel analysis and necessitates the reliance on finite element analysis. The current paper describes the NCSX vacuum vessel stress analysis including external pressure, thermal, and electro-magnetic loading from internal plasma disruptions and bakeout temperatures of up to 400 degrees centigrade. Buckling and dynamic loading conditions are also considered

  14. Modification method to reduce the impact of blood vessel on noncontact discrimination of human blood based on ;M+N; theory

    Science.gov (United States)

    Zhang, Linna; Ding, Hongyan; Lin, Ling; Wang, Yimin; Guo, Xin

    2018-01-01

    Noncontact discriminating human blood is significantly crucial for import-export ports and inspection and quarantine departments. We had already demonstrated that visible diffuse reflectance spectroscopy combining PLS-DA method can successfully realize noncontact human blood discrimination. However, the circulated blood vessels may be produced with different materials. The use of various kinds of blood tubes may have a negative effect on the discrimination, based on ;M+N; theory (Li et al., 2016). In this research, we explored the impact of different material of blood vessels, such as glass tube and plastic tube, on the prediction ability of the discrimination model. Furthermore, we searched for the modification method to reduce the influence from the blood tubes. Our work indicated that generalized diffuse reflectance method can greatly improve the discrimination accuracy. This research can greatly facilitate the application of noncontact discrimination method based on visible and near-infrared diffuse reflectance spectroscopy.

  15. Holographic and acoustic emission evaluation of pressure vessels

    International Nuclear Information System (INIS)

    Boyd, D.M.

    1980-01-01

    Optical holographic interfereometry and acoustic emission monitoring were simultaneously used to evaluate two small, high pressure vessels during pressurization. The techniques provide pressure vessel designers with both quantitative information such as displacement/strain measurements and qualitative information such as flaw detection. The data from the holographic interferograms were analyzed for strain profiles. The acoustic emission signals were monitored for crack growth and vessel quality

  16. Neutron Assay System for Con?nement Vessel Disposition

    International Nuclear Information System (INIS)

    Frame, Katherine C.; Bourne, Mark M.; Crooks, William J.; Evans, Louise; Mayo, Douglas R.; Miko, David K.; Salazar, William R.; Stange, Sy; Valdez, Jose I.; Vigil, Georgiana M.

    2012-01-01

    Waste will be removed from confinement vessels remaining from 1970s-era experiments. Los Alamos has 9+ spherical confinement vessels remaining from experiments. Each vessel contains ∼ 500 lbs of radioactive debris such as actinide metals and oxides, metals, powdered silica, graphite, and wires and hardware. In order to dispose of the vessels, debris and contamination must be removed. Neutron assay system was designed to assay vessels before and after cleanout. System requirements are: (1) Modular and moveable; (2) Capable of detecting ∼100g 239 Pu equivalent in a 2-inch thick steel sphere with 6 foot diameter; and (3) Capable of safeguards-quality assays. Initial design parameters arethe use of 4-atm 3 He tubes with length of 6 feet, and 3 He tubes embedded in polyethelene for moderation. This paper describes the calibration of the Confinement Vessel Assay System (CVAS) and quantification of its uncertainties. Assay uncertainty depends on five factors: (1) Statistical uncertainty in the assay measurement; (2) Statistical uncertainty in the background measurement; (3) Statistical uncertainty in the isotopics determination - This should be much smaller than the other uncertainties; (4) Systematic uncertainty due to position bias; and (5) Systematic uncertainty due to fluctuations in cosmic ray spallation. This one can be virtually eliminated by performing the background measurement with an empty vessel - but that may not be possible. We used modeling and experiments to quantify the systematic uncertainties. The calibration assumes a uniform distribution of material, but reality will be different. MCNPX modeling was used to quantify the positional bias. The model was benchmarked to build confidence in its results. Material at top of vessel is 44% greater than amount assayed, according to singles. Material near 19-tube detector is 38% less than amount assayed, according to singles. Cosmic ray spallation contributes significantly to the background. Comparing rates

  17. Development of TPNCIRC code for Evaluation of Two-Phase Natural Circulation Flow Performance under External Reactor Vessel Cooling Conditions

    International Nuclear Information System (INIS)

    Choi, A-Reum; Song, Hyuk-Jin; Park, Jong-Woon

    2015-01-01

    During a severe accident, corium is relocated to the lower head of the nuclear reactor pressure vessel (RPV). Design concept of retaining the corium inside a nuclear reactor pressure vessel (RPV) through external cooling under hypothetical core melting accidents is called external reactor vessel cooling (ERVC). In this respect, validated two-phase natural circulation flow (TPNC) model is necessary to determine the adequacy of the ERVC design and operating conditions such as inlet area, form losses, gap distance, riser length and coolant conditions. The most important model generally characterizing the TPNC are void fraction and two-phase friction factors. Typical experimental and analytical studies to be referred to on two-phase circulation flow characteristics are those by Reyes, Gartia et al. based on Vijayan et al., Nayak et al. and Dubey et al. In the present paper, two-phase natural circulation (TPNC) flow characteristics under external reactor vessel cooling (ERVC) conditions are studied using two existing TPNC flow models of Reyes and Gartia et al. incorporating more improved void fraction and two-phase friction models. These models and correlations are integrated into a computer program, TPNCIRC, which can handle candidate ERVC design parameters, such as inlet, riser and downcomer flow lengths and areas, gap size between reactor vessel and surrounding insulations, minor loss factors and operating parameters of decay power, pressure and subcooling. Accuracy of the TPNCIRC program is investigated with respect to the flow rate and void fractions for existing measured data from a general experiment and ULPU specifically designed for the AP1000 in-vessel retention. Also, the effect of some important design parameters are examined for the experimental and plant conditions. Using the flow models and correlations are integrated into a computer program, TPNCIRC, a number of correlations have been examined. This seems coming from the differences of void fractions

  18. A thermal insulation system intended for a prestressed concrete vessel

    International Nuclear Information System (INIS)

    Aubert, Gilles; Petit, Guy.

    1975-01-01

    The description is given of a thermal insulation system withstanding the pressure of a vaporisable fluid for a prestressed concrete vessel, particularly the vessel of a boiling water nuclear reactor. The ring in the lower part of the vessel has, between the fluid inlet pipes and the bottom of the vessel, an annular opening of which the bottom edge is integral with an annular part rising inside the ring and parallel to it. This ring is hermetically connected to the bottom of the vessel and is coated with a metal lagging, at least facing the annular opening. This annular opening is made in the ring half-way up between the fluid inlet pipes and the bottom of the vessel. It is connected to the bottom of the vessel through the internal structure enveloping the reactor core [fr

  19. In-vessel core debris retention experiments. Final report

    International Nuclear Information System (INIS)

    1998-10-01

    The in-vessel cooling experimental program (Phase 1 and 2) was motivated by the survivability of the TMI lower vessel head during the TMI-2 accident. During that accident, molten debris relocation into the water filled lower head resulted in a localized hot spot in the lower head, but no lower head failure occurred. A postulated set of mechanisms which could be involved in and responsible for the survivability of the TMI lower head were identified and experimentally investigated as part of this program. These mechanisms included: the formation of a gap (contact resistance) between the relocated and frozen debris and the vessel wall was a key aspect of the in-vessel cooling mechanism; wall heatup due to the relocated debris in the presence of wall stress due to a pressure gradient across the vessel wall; gap growth due to a lack of debris adherence to the vessel wall and material creep of the heated vessel wall; and the potential for enhanced wall cooling due to gap growth. Each of these postulated mechanisms was investigated in this experimental program. This report summarizes the several insights and conclusions that were obtained from this experimental program. This report documents the entire set of five experiments completed in Phase 2 of this experimental program. Results from the Phase 1 effort were used to plan and select the Phase 2 test matrix. Conclusions from the Phase 1 and 2 experiments are identified and recommendations for future work are provided

  20. Ex-vessel boiling experiments: laboratory- and reactor-scale testing of the flooded cavity concept for in-vessel core retention. Pt. II. Reactor-scale boiling experiments of the flooded cavity concept for in-vessel core retention

    International Nuclear Information System (INIS)

    Chu, T.Y.; Bentz, J.H.; Slezak, S.E.; Pasedag, W.F.

    1997-01-01

    For pt.I see ibid., p.77-88 (1997). This paper summarizes the results of a reactor-scale ex-vessel boiling experiment for assessing the flooded cavity design of the heavy water new production reactor. The simulated reactor vessel has a cylindrical diameter of 3.7 m and a torispherical bottom head. Boiling outside the reactor vessel was found to be subcooled nucleate boiling. The subcooling mainly results from the gravity head, which in turn results from flooding the side of the reactor vessel. The boiling process exhibits a cyclic pattern with four distinct phases: direct liquid-solid contact, bubble nucleation and growth, coalescence, and vapor mass dispersion. The results show that, under prototypic heat load and heat flux distributions, the flooded cavity will be effective for in-vessel core retention in the heavy water new production reactor. The results also demonstrate that the heat dissipation requirement for in-vessel core retention, for the central region of the lower head of an AP-600 advanced light water reactor, can be met with the flooded cavity design. (orig.)

  1. Summary of Reported Whale-Vessel Collisions in Alaskan Waters

    Directory of Open Access Journals (Sweden)

    Janet L. Neilson

    2012-01-01

    Full Text Available Here we summarize 108 reported whale-vessel collisions in Alaska from 1978–2011, of which 25 are known to have resulted in the whale's death. We found 89 definite and 19 possible/probable strikes based on standard criteria we created for this study. Most strikes involved humpback whales (86% with six other species documented. Small vessel strikes were most common (<15 m, 60%, but medium (15–79 m, 27% and large (≥80 m, 13% vessels also struck whales. Among the 25 mortalities, vessel length was known in seven cases (190–294 m and vessel speed was known in three cases (12–19 kn. In 36 cases, human injury or property damage resulted from the collision, and at least 15 people were thrown into the water. In 15 cases humpback whales struck anchored or drifting vessels, suggesting the whales did not detect the vessels. Documenting collisions in Alaska will remain challenging due to remoteness and resource limitations. For a better understanding of the factors contributing to lethal collisions, we recommend (1 systematic documentation of collisions, including vessel size and speed; (2 greater efforts to necropsy stranded whales; (3 using experienced teams focused on determining cause of death; (4 using standard criteria for validating collision reports, such as those presented in this paper.

  2. Nuclear reactor with a suspended vessel

    International Nuclear Information System (INIS)

    Lemercier, Guy.

    1977-01-01

    This invention relates to a nuclear reactor with a suspended vessel and applies in particular when this is a fast reactor, the core or active part of the reactor being inside the vessel and immersed under a suitable volume of flowing liquid metal to cool it by extracting the calories released by the nuclear fission in the fuel assemblies forming this core [fr

  3. Results of reactor pressure vessels ISI

    International Nuclear Information System (INIS)

    Cepcek, S.

    1994-01-01

    To find out the possible influence of the annealing process to reactor pressure vessel integrity, a large in-service inspection programme has been implemented as an associated activity to reactor pressure vessel annealing. In this paper the approach to the RPV in-service inspection is shown. Also, the main results and conclusions following in-service inspection are presented. (author). 3 refs, 1 fig

  4. The Benefits of Targeted Memory Reactivation for Consolidation in Sleep are Contingent on Memory Accuracy and Direct Cue-Memory Associations.

    Science.gov (United States)

    Cairney, Scott A; Lindsay, Shane; Sobczak, Justyna M; Paller, Ken A; Gaskell, M Gareth

    2016-05-01

    To investigate how the effects of targeted memory reactivation (TMR) are influenced by memory accuracy prior to sleep and the presence or absence of direct cue-memory associations. 30 participants associated each of 50 pictures with an unrelated word and then with a screen location in two separate tasks. During picture-location training, each picture was also presented with a semantically related sound. The sounds were therefore directly associated with the picture locations but indirectly associated with the words. During a subsequent nap, half of the sounds were replayed in slow wave sleep (SWS). The effect of TMR on memory for the picture locations (direct cue-memory associations) and picture-word pairs (indirect cue-memory associations) was then examined. TMR reduced overall memory decay for recall of picture locations. Further analyses revealed a benefit of TMR for picture locations recalled with a low degree of accuracy prior to sleep, but not those recalled with a high degree of accuracy. The benefit of TMR for low accuracy memories was predicted by time spent in SWS. There was no benefit of TMR for memory of the picture-word pairs, irrespective of memory accuracy prior to sleep. TMR provides the greatest benefit to memories recalled with a low degree of accuracy prior to sleep. The memory benefits of TMR may also be contingent on direct cue-memory associations. © 2016 Associated Professional Sleep Societies, LLC.

  5. 46 CFR 2.10-105 - Prepayment of annual vessel inspection fees.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 1 2010-10-01 2010-10-01 false Prepayment of annual vessel inspection fees. 2.10-105... VESSEL INSPECTIONS Fees § 2.10-105 Prepayment of annual vessel inspection fees. (a) Vessel owners may prepay the annual vessel inspection fee for any period of not less than three years, and not more than...

  6. Tubular inverse opal scaffolds for biomimetic vessels

    Science.gov (United States)

    Zhao, Ze; Wang, Jie; Lu, Jie; Yu, Yunru; Fu, Fanfan; Wang, Huan; Liu, Yuxiao; Zhao, Yuanjin; Gu, Zhongze

    2016-07-01

    There is a clinical need for tissue-engineered blood vessels that can be used to replace or bypass damaged arteries. The success of such grafts depends strongly on their ability to mimic native arteries; however, currently available artificial vessels are restricted by their complex processing, controversial integrity, or uncontrollable cell location and orientation. Here, we present new tubular scaffolds with specific surface microstructures for structural vessel mimicry. The tubular scaffolds are fabricated by rotationally expanding three-dimensional tubular inverse opals that are replicated from colloidal crystal templates in capillaries. Because of the ordered porous structure of the inverse opals, the expanded tubular scaffolds are imparted with circumferentially oriented elliptical pattern microstructures on their surfaces. It is demonstrated that these tailored tubular scaffolds can effectively make endothelial cells to form an integrated hollow tubular structure on their inner surface and induce smooth muscle cells to form a circumferential orientation on their outer surface. These features of our tubular scaffolds make them highly promising for the construction of biomimetic blood vessels.There is a clinical need for tissue-engineered blood vessels that can be used to replace or bypass damaged arteries. The success of such grafts depends strongly on their ability to mimic native arteries; however, currently available artificial vessels are restricted by their complex processing, controversial integrity, or uncontrollable cell location and orientation. Here, we present new tubular scaffolds with specific surface microstructures for structural vessel mimicry. The tubular scaffolds are fabricated by rotationally expanding three-dimensional tubular inverse opals that are replicated from colloidal crystal templates in capillaries. Because of the ordered porous structure of the inverse opals, the expanded tubular scaffolds are imparted with circumferentially

  7. Cooling system for the connecting rings of a fast neutron reactor vessel

    International Nuclear Information System (INIS)

    Martin, J.-P.; Malaval, Claude

    1974-01-01

    A description is given of a cooling system for the vessel connecting rings of a fast neutron nuclear reactor, particularly of a main vessel containing the core of the reactor and a volume of liquid metal coolant at high temperature and a safety vessel around the main vessel, both vessels being suspended to a rigid upper slab kept at a lower temperature. It is mounted in the annular space between the two vessels and includes a neutral gas circuit set up between the wall of the main vessel to be cooled and that of the safety vessel itself cooled from outer. The neutral gas system comprises a plurality of ventilators fitted in holes made through the thickness of the upper slab and opening on to the space between the two vessels. It also includes two envelopes lining the walls of these vessels, establishing with them small section channels for the circulation of the neutral gas cooled against the safety vessel and heated against the main vessel [fr

  8. Elastic plastic buckling of elliptical vessel heads

    International Nuclear Information System (INIS)

    Alix, M.; Roche, R.L.

    1981-08-01

    The risks of buckling of dished vessel head increase when the vessel is thin walled. This paper gives the last results on experimental tests of 3 elliptical heads and compares all the results with some empirical formula dealing with elastic and plastic buckling

  9. Variable Accuracy of Wearable Heart Rate Monitors during Aerobic Exercise.

    Science.gov (United States)

    Gillinov, Stephen; Etiwy, Muhammad; Wang, Robert; Blackburn, Gordon; Phelan, Dermot; Gillinov, A Marc; Houghtaling, Penny; Javadikasgari, Hoda; Desai, Milind Y

    2017-08-01

    Athletes and members of the public increasingly rely on wearable HR monitors to guide physical activity and training. The accuracy of newer, optically based monitors is unconfirmed. We sought to assess the accuracy of five optically based HR monitors during various types of aerobic exercise. Fifty healthy adult volunteers (mean ± SD age = 38 ± 12 yr, 54% female) completed exercise protocols on a treadmill, a stationary bicycle, and an elliptical trainer (±arm movement). Each participant underwent HR monitoring with an electrocardiogaphic chest strap monitor (Polar H7), forearm monitor (Scosche Rhythm+), and two randomly assigned wrist-worn HR monitors (Apple Watch, Fitbit Blaze, Garmin Forerunner 235, and TomTom Spark Cardio), one on each wrist. For each exercise type, HR was recorded at rest, light, moderate, and vigorous intensity. Agreement between HR measurements was assessed using Lin's concordance correlation coefficient (rc). Across all exercise conditions, the chest strap monitor (Polar H7) had the best agreement with ECG (rc = 0.996) followed by the Apple Watch (rc = 0.92), the TomTom Spark (rc = 0.83), and the Garmin Forerunner (rc = 0.81). Scosche Rhythm+ and Fitbit Blaze were less accurate (rc = 0.75 and rc = 0.67, respectively). On treadmill, all devices performed well (rc = 0.88-0.93) except the Fitbit Blaze (rc = 0.76). While bicycling, only the Garmin, Apple Watch, and Scosche Rhythm+ had acceptable agreement (rc > 0.80). On the elliptical trainer without arm levers, only the Apple Watch was accurate (rc = 0.94). None of the devices was accurate during elliptical trainer use with arm levers (all rc < 0.80). The accuracy of wearable, optically based HR monitors varies with exercise type and is greatest on the treadmill and lowest on elliptical trainer. Electrode-containing chest monitors should be used when accurate HR measurement is imperative.

  10. Non-linear analysis up to rupture of a model of a multi-cavity prestressed concrete pressure vessel

    International Nuclear Information System (INIS)

    Rebora, B.; Uffer, F.; Zimmermann, T.

    1977-01-01

    Within the frame of a German-Swiss agreement concerning the project of a high-temperature nuclear plant (HHT), the Swiss Federal Institute for Reactor Research (EIR, in Wuerlingen) has developed an integrated variant of an helium-cooled high temperature reactor of 3x500 Mwe. A test on a model (1:20) of this prestressed concrete nuclear vessel with multiple cavities has been carried out under the supervision of 'Bonnard et Gardel ingenieurs-conseils SA (BG). The aim of this analysis is to determine the mechanism of ruin and ultimate load of the structure. In addition, comparison with the results of the test emphasizes the mathematical model with a view to its utilisation for the analysis of any prestressed concrete nuclear vessel. The principal interest of this paper is to show the accuracy of non-linear analysis of a complex massive structure with the test results and the evolution of the behaviour of the structure from the apparition of the first crack up to the ruin by rupture of the steel wires. (Auth.)

  11. Automatic segmentation of blood vessels from retinal fundus images ...

    Indian Academy of Sciences (India)

    The retinal blood vessels were segmented through color space conversion and color channel .... Retinal blood vessel segmentation was also attempted through multi-scale operators. A few works in this ... fundus camera at 35 degrees field of view. The image ... vessel segmentation is available from two human observers.

  12. Pressure vessel for a BWR type reactor

    International Nuclear Information System (INIS)

    Shimamoto, Yoshiharu.

    1980-01-01

    Purpose: To prevent the retention of low temperature water and also prevent the thermal fatigue of the pressure vessel by making large the curvature radius of a pressure vessel of a feed water sparger fitting portion and accelerating the mixing of low-temperature water at the feed water sparger base and in-pile hot water. Constitution: The curvature radius of the corner of the feed water sparger fitting portion in a pressure vessel is formed largely. In-pile circulating water infiltrates up to the base portion of the feed water sparger to carry outside low-temperature water at the base part, which is mixed with in-pile hot water. Accordingly, low temperature water does not stay at the base portion of the feed water sparger and generation of thermal fatigue in the pressure vessel can be prevented and the safety of the BWR type reactor can be improved. (Yoshino, Y.)

  13. Some aspects of reactor pressure vessel integrity

    International Nuclear Information System (INIS)

    Korosec, D.; Vojvodic, G.J.

    1996-01-01

    Reactor pressure vessel of the pressurized water reactor nuclear power plant is the subject of extreme interest due to the fact that presents the pressure boundary of the reactor coolant system, which is under extreme thermal, mechanical and irradiation effects. Reactor pressure vessel by itself prevents the release of fission products to the environment. Design, construction and in-service inspection of such component is governed by strict ASME rules and other forms of administrative control. The reactor pressure vessel in nuclear power plant Kriko is designed and constructed in accordance with related ASME rules. The in-service inspection program includes all requests presented in ASME Code section XI. In the present article all major requests for the periodic inspections of reactor pressure vessel and fracture mechanics analysis are discussed. Detailed and strict fulfillment of all prescribed provisions guarantee the appropriate level of nuclear safety. (author)

  14. 19 CFR 4.1 - Boarding of vessels; cutter and dock passes.

    Science.gov (United States)

    2010-04-01

    ... 19 Customs Duties 1 2010-04-01 2010-04-01 false Boarding of vessels; cutter and dock passes. 4.1... OF THE TREASURY VESSELS IN FOREIGN AND DOMESTIC TRADES Arrival and Entry of Vessels § 4.1 Boarding of... regulations. (4) The master of any vessel shall not authorize the boarding or leaving of his vessel by any...

  15. The conditions for attaining the greatest degree of system stability with strict generator excitation control

    Energy Technology Data Exchange (ETDEWEB)

    Gruzdev, I.A.; Ekimova, M.M.; Truspekova, G.A.

    1982-01-01

    Expressions are derived for an idealized model of a complex electric power system; these expressions define the greatest level of stability of an electric power system and the optimum combination of stabilization factors with automatic excitation control in a single power system. The possibility of increasing the level of stability of an electric power system with simultaneous strict automatic excitation control of the synychronous generators in several power systems is analyzed.

  16. Stress criteria for nuclear vessel concrete

    International Nuclear Information System (INIS)

    Costes, D.

    1975-01-01

    Concrete nuclear vessels are submitted to prestressing forces which limit tensile stresses in concrete when the vessel is under pressure with thermal gradients. Hence, the most severe conditions for concrete appear when the vessel is prestressed and not submitted to internal pressure. The triaxial states of stress in the concrete may be computed postulating elastic or other behavior and compared with safe limits obtained from rupture tests and fatigue tests. The first part of the paper, recalls experimental rupture results and the acceptability procedures currently used. Criteria founded on the lemniscoid surfaces are proposed, parameters for which are obtained by various tests and safety considerations. In the second part, rupture tests are reported on small, thick, cylindrical vessels submitted to external hydraulic pressure simulating prestressing forces. Materials used are plain concrete, microconcrete, marble and graphite. The strengths obtained are much higher than those which could be elastically computed, triaxial rupture states being provided by previous experiments. Such results may be due to a plastic stress redistribution before fracture and to stabilizing effects of stress gradients around the more stressed areas. Fatigue tests by external hydraulic loading are reported [fr

  17. Experimental Validation of Ex-Vessel Neutron Spectrum by Means of Dosimeter Materials Activation Method

    Directory of Open Access Journals (Sweden)

    S.A. Santa

    2017-06-01

    Full Text Available Neutron spectrum information in reactor core and around of ex-vessel reactor needs to be known with a certain degree of accuracy to support the development of fuels, materials, and other components. The most common method to determine neutron spectra is by utilizing the radioactivation of dosimeter materials. This report presents the evaluation of neutron flux incident on M3dosimeter sets which were irradiated outside the reactor vessel,as well as the validation of  neutron spectrum calculation. Al capsules containing both dosimeter set covered withCd and dosimeter set without Cd cover have been irradiated during the 35th operational cycle in the M3 ex-vessel irradiation hole position207 cmfrom core centerline at the space between the reactor vessel and the safety vessel. The capsules were positioned at Z=0.0 cm of core midplane. Each dosimeter set consists of Co-Al, Sc, Fe, Np, Nb, Ni, B, and Ta. The gamma-ray spectra of irradiated dosimeter materials were measured by 63 cc HPGe solid-state detector and photo-peak spectra were analyzed using BOB75 code. The reaction rates of each dosimeter materials and its uncertainty were analyzed based on 59Co (n,g 60Co, 237Np (n,f 95Zr-103Ru,  45Sc (n,g 46Sc, 58Fe (n,g 59Fe, 181Ta (n,g 182Ta, and 58Ni (n,p58Co reactions. The measured Cd ratios indicate that neutron spectrum at the irradiated dosimeter sets was dominated by low energy neutron. The experimental result shows that the calculated neutron spectra by DORT code at the ex-vessel positions need correction, especially in the fast neutron energy region, so as to obtain reasonable unfolding result consistent with the reaction rate measurement without any exception. Using biased DORT initial spectrum, the neutron spectrum and its integral quantity were unfolded by NEUPAC code. The result shows that total neutron flux, flux above 1.0 MeV, flux above 0.1 MeV, and the displacement rate of the dosimeter set not covered with Cd were 1.75× 1012 n cm2 s-1, 1

  18. Thermal-buckling analysis of an LMFBR overflow vessel

    International Nuclear Information System (INIS)

    Severud, L.K.

    1983-01-01

    During a reactor scram, cold sodium flows into the hot overflow vessel. The effect on the vessel is a compressive thermal stress in a zone just above the sodium level. This condition must be sufficiently controlled to preclude thermal buckling. Also, under repeated scrams, the vessel should not suffer thermal stress low cycle fatigue. To evaluate the closeness to buckling and satisfaction of ASMA Code limits, a combination of simple approximations, detailed elastic shell buckling analyses, and correlations to results of thermal buckling tests were employed. This paper describes the analysis methods, special considerations, and evaluations accomplished for this FFTF vessel to assure satisfaction of ASME buckling design criteria, rules, and limits

  19. Problems in Pressure Vessel Design and Manufacture

    Energy Technology Data Exchange (ETDEWEB)

    Hellstroem, O [Uddeholms AB, Degerfors (Sweden); Nilson, Ragnar [AB Atomenergi, Nykoeping (Sweden)

    1963-05-15

    The general desire by the power reactor process makers to increase power rating and their efforts to involve more advanced thermal behaviour and fuel handling facilities within the reactor vessels are accompanied by an increase in both pressure vessel dimensions and various difficulties in giving practical solutions of design materials and fabrication problems. In any section of this report it is emphasized that difficulties and problems already met with will meet again in the future vessels but then in modified forms and in many cases more pertinent than before. As for the increase in geometrical size it can be postulated that with use of better materials and adjusted fabrication methods the size problems can be taken proper care of. It seems likely that vessels of sufficient large diameter and height for the largest power output, which is judged as interesting in the next ten year period, can be built without developing totally new site fabrication technique. It is, however, supposed that such a fabrication technique will be feasible though at higher specific costs for the same quality requirements as obtained in shop fabrication. By the postulated use of more efficient vessel material with principally the same good features of easy fabrication in different stages such as preparation, welding, heat treatment etc as ordinary or slightly modified carbon steels the increase in wall thickness might be kept low. There exists, however, a development work to be done for low-alloy steels to prove their justified use in large reactor pressure vessels.

  20. Manufacture of EAST VS In-Vessel Coil

    International Nuclear Information System (INIS)

    Long, Feng; Wu, Yu; Du, Shijun; Jin, Huan; Yu, Min; Han, Qiyang; Wan, Jiansheng; Liu, Bin; Qiao, Jingchun; Liu, Xiaochuan; Li, Chang; Cai, Denggang; Tong, Yunhua

    2013-01-01

    Highlights: • ITER like Stainless Steel Mineral Insulation Conductor (SSMIC) used for EAST Tokamak VS In-Vessel Coil manufacture first time. • Research on SSMIC fabrication was introduced in detail. • Two sets totally four single-turn VS coils were manufactured and installed in place symmetrically above and below the mid-plane in the vacuum vessel of EAST. • The manufacture and inspection of the EAST VS coil especially the joint for the SSMIC connection was described in detail. • The insulation resistances of all the VS coils have no significant reduction after endurance test. -- Abstract: In the ongoing latest update round of EAST (Experimental Advanced Superconducting Tokamak), two sets of two single-turn Vertical Stabilization (VS) coils were manufactured and installed symmetrically above and below the mid-plane in the vacuum vessel of EAST. The Stainless Steel Mineral Insulated Conductor (SSMIC) developed for ITER In-Vessel Coils (IVCs) in Institute of Plasma Physics, Chinese Academy of Science (ASIPP) was used for the EAST VS coils manufacture. Each turn poloidal field VS coil includes three internal joints in the vacuum vessel. The middle joint connects two pieces of conductor which together form an R2.3 m arc segment inside the vacuum vessel. The other two joints connect the arc segment with the two feeders near the port along the toroidal direction to bear lower electromagnetic loads during operation. Main processes and tests include material performances checking, conductor fabrication, joint connection and testing, coil forming, insulation performances measurement were described herein

  1. Problems in Pressure Vessel Design and Manufacture

    International Nuclear Information System (INIS)

    Hellstroem, O.; Nilson, Ragnar

    1963-05-01

    The general desire by the power reactor process makers to increase power rating and their efforts to involve more advanced thermal behaviour and fuel handling facilities within the reactor vessels are accompanied by an increase in both pressure vessel dimensions and various difficulties in giving practical solutions of design materials and fabrication problems. In any section of this report it is emphasized that difficulties and problems already met with will meet again in the future vessels but then in modified forms and in many cases more pertinent than before. As for the increase in geometrical size it can be postulated that with use of better materials and adjusted fabrication methods the size problems can be taken proper care of. It seems likely that vessels of sufficient large diameter and height for the largest power output, which is judged as interesting in the next ten year period, can be built without developing totally new site fabrication technique. It is, however, supposed that such a fabrication technique will be feasible though at higher specific costs for the same quality requirements as obtained in shop fabrication. By the postulated use of more efficient vessel material with principally the same good features of easy fabrication in different stages such as preparation, welding, heat treatment etc as ordinary or slightly modified carbon steels the increase in wall thickness might be kept low. There exists, however, a development work to be done for low-alloy steels to prove their justified use in large reactor pressure vessels

  2. Application of material databases for improved reliability of reactor pressure vessels

    International Nuclear Information System (INIS)

    Griesbach, T.J.; Server, W.L.; Beaudoin, B.F.; Burgos, B.N.

    1994-01-01

    A vital part of reactor vessel Life Cycle Management program must begin with an accurate characterization of the vessel material properties. Uncertainties in vessel material properties or use of bounding values may result in unnecessary conservatisms in vessel integrity calculations. These conservatisms may be eliminated through a better understanding of the material properties in reactor vessels, both in the unirradiated and irradiated conditions. Reactor vessel material databases are available for quantifying the chemistry and Charpy shift behavior of individual heats of reactor vessel materials. Application of the databases for vessels with embrittlement concerns has proven to be an effective embrittlement management tool. This paper presents details of database development and applications which demonstrate the value of using material databases for improving material chemistry and for maximizing the data from integrated material surveillance programs

  3. Effect of print layer height and printer type on the accuracy of 3-dimensional printed orthodontic models.

    Science.gov (United States)

    Favero, Christian S; English, Jeryl D; Cozad, Benjamin E; Wirthlin, John O; Short, Megan M; Kasper, F Kurtis

    2017-10-01

    Three-dimensional (3D) printing technologies enable production of orthodontic models from digital files; yet a range of variables associated with the process could impact the accuracy and clinical utility of the models. The objective of this study was to investigate the effect of print layer height on the accuracy of orthodontic models printed 3 dimensionally using a stereolithography format printer and to compare the accuracy of orthodontic models fabricated with several commercially available 3D printers. Thirty-six identical models were produced with a stereolithography-based 3D printer using 3 layer heights (n = 12 per group): 25, 50, and 100 μm. Forty-eight additional models were printed using 4 commercially available 3D printers (n = 12 per group). Each printed model was digitally scanned and compared with the input file via superimposition analysis using a best-fit algorithm to assess accuracy. Statistically significant differences were found in the average overall deviations of models printed at each layer height, with the 25-μm and 100-μm layer height groups having the greatest and least deviations, respectively. Statistically significant differences were also found in the average overall deviations of models produced using the various 3D printer models, but all values fell within clinically acceptable limits. The print layer height and printer model can affect the accuracy of a 3D printed orthodontic model, but the impact should be considered with respect to the clinical tolerances associated with the envisioned application. Copyright © 2017 American Association of Orthodontists. Published by Elsevier Inc. All rights reserved.

  4. Vessel generator noise as a settlement cue for marine biofouling species.

    Science.gov (United States)

    McDonald, J I; Wilkens, S L; Stanley, J A; Jeffs, A G

    2014-01-01

    Underwater noise is increasing globally, largely due to increased vessel numbers and international ocean trade. Vessels are also a major vector for translocation of non-indigenous marine species which can have serious implications for biosecurity. The possibility that underwater noise from fishing vessels may promote settlement of biofouling on hulls was investigated for the ascidian Ciona intestinalis. Spatial differences in biofouling appear to be correlated with spatial differences in the intensity and frequency of the noise emitted by the vessel's generator. This correlation was confirmed in laboratory experiments where C. intestinalis larvae showed significantly faster settlement and metamorphosis when exposed to the underwater noise produced by the vessel generator. Larval survival rates were also significantly higher in treatments exposed to vessel generator noise. Enhanced settlement attributable to vessel generator noise may indicate that vessels not only provide a suitable fouling substratum, but vessels running generators may be attracting larvae and enhancing their survival and growth.

  5. 46 CFR 111.105-45 - Vessels carrying agricultural products.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 4 2010-10-01 2010-10-01 false Vessels carrying agricultural products. 111.105-45... ENGINEERING ELECTRIC SYSTEMS-GENERAL REQUIREMENTS Hazardous Locations § 111.105-45 Vessels carrying agricultural products. (a) The following areas are Class II, Division 1, (Zone 10 or Z) locations on vessels...

  6. 40 CFR 1042.130 - Installation instructions for vessel manufacturers.

    Science.gov (United States)

    2010-07-01

    ...) AIR POLLUTION CONTROLS CONTROL OF EMISSIONS FROM NEW AND IN-USE MARINE COMPRESSION-IGNITION ENGINES...-speed operation, tell vessel manufacturers not to install the engines in variable-speed applications or... vessel manufacturers. (a) If you sell an engine for someone else to install in a vessel, give the engine...

  7. Manipulator arm for a nuclear reactor vessel inspection device

    International Nuclear Information System (INIS)

    1980-01-01

    A manipulator arm for a reactor vessel in-service inspection apparatus is adapted to transport a transducer array for ultrasonic examination of welds at any point in the vessel. The removal of the inspection device from the reactor vessel in an emergency presents a problem where a relatively long manipulator arm is used. This invention provides an improved arm with means for changing the normal orientation of the arm to a shorter one to permit safe removal of the inspection device from the reactor vessel. (author)

  8. Distribution of normal superficial ocular vessels in digital images.

    Science.gov (United States)

    Banaee, Touka; Ehsaei, Asieh; Pourreza, Hamidreza; Khajedaluee, Mohammad; Abrishami, Mojtaba; Basiri, Mohsen; Daneshvar Kakhki, Ramin; Pourreza, Reza

    2014-02-01

    To investigate the distribution of different-sized vessels in the digital images of the ocular surface, an endeavor which may provide useful information for future studies. This study included 295 healthy individuals. From each participant, four digital photographs of the superior and inferior conjunctivae of both eyes, with a fixed succession of photography (right upper, right lower, left upper, left lower), were taken with a slit lamp mounted camera. Photographs were then analyzed by a previously described algorithm for vessel detection in the digital images. The area (of the image) occupied by vessels (AOV) of different sizes was measured. Height, weight, fasting blood sugar (FBS) and hemoglobin levels were also measured and the relationship between these parameters and the AOV was investigated. These findings indicated a statistically significant difference in the distribution of the AOV among the four conjunctival areas. No significant correlations were noted between the AOV of each conjunctival area and the different demographic and biometric factors. Medium-sized vessels were the most abundant vessels in the photographs of the four investigated conjunctival areas. The AOV of the different sizes of vessels follows a normal distribution curve in the four areas of the conjunctiva. The distribution of the vessels in successive photographs changes in a specific manner, with the mean AOV becoming larger as the photos were taken from the right upper to the left lower area. The AOV of vessel sizes has a normal distribution curve and medium-sized vessels occupy the largest area of the photograph. Copyright © 2013 British Contact Lens Association. Published by Elsevier Ltd. All rights reserved.

  9. Laparoscopic prototype for optical sealing of renal blood vessels

    Science.gov (United States)

    Hardy, Luke A.; Hutchens, Thomas C.; Larson, Eric R.; Gonzalez, David A.; Chang, Chun-Hung; Nau, William H.; Fried, Nathaniel M.

    2017-02-01

    Energy-based, radiofrequency and ultrasonic devices provide rapid sealing of blood vessels during laparoscopic procedures. We are exploring infrared lasers as an alternative for vessel sealing with less collateral thermal damage. Previous studies demonstrated vessel sealing in an in vivo porcine model using a 1470-nm laser. However, the initial prototype was designed for open surgery and featured tissue clasping and light delivery mechanisms incompatible with laparoscopic surgery. In this study, a laparoscopic prototype similar to devices in surgical use was developed, and tests were conducted on porcine renal blood vessels. The 5-mm-OD prototype featured a traditional Maryland jaw configuration. Laser energy was delivered through a 550-μm-core fiber and side-delivery from the lower jaw, with beam dimensions of 18-mm-length x 1.2-mm-width. The 1470-nm diode laser delivered 68 W with 3 s activation time. A total of 69 porcine renal vessels with mean diameter of 3.3 +/- 1.7 mm were tested, ex vivo. Vessels smaller than 5 mm were consistently sealed (48/51) with burst pressures greater than malignant hypertension blood pressure (180 mmHg), averaging 1038 +/- 474 mmHg. Vessels larger than 5 mm were not consistently sealed (6/18), yielding burst pressures of only 174 +/- 221 mmHg. Seal width, thermal damage zone, and thermal spread averaged 1.7 +/- 0.8, 3.4 +/- 0.7, and 1.0 +/- 0.4 mm. A novel optical laparoscopic prototype with 5-mm- OD shaft integrated within a standard Maryland jaw design consistently sealed vessels less than 5 mm with minimal thermal spread. Further in vivo studies are planned to test performance across a variety of vessels and tissues.

  10. A study of reactor vessel integrity assessment

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Jae Hoon [Korea Institute of Nuclear Safety, Taejon (Korea, Republic of); Kim, Jong Kyung; Shin, Chang Ho; Seo, Bo Kyun [Hanyang Univ., Seoul (Korea, Republic of)

    1999-02-15

    The fast neutron fluence at the Reactor Pressure Vessel(RPV) of KNGR designed for 60 years lifetime was calculated by full-scope Monte Carlo simulation for reactor vessel integrity assessment. KNGR core geometry was modeled on a three-dimensional representation of the one-sixteenth of the reactor in-vessel component. Each fuel assemblies were modeled explicitly, and each fuel pins were axially divided into 5 segments. The maximum flux of 4.3 x 10{sup 10} neutrons/cm{sup 2}. sec at the RPV was obtained by tallying neutrons crossing the beltline of inner surface of the RPV.

  11. Gas-liquid flow filed in agitated vessels

    International Nuclear Information System (INIS)

    Hormazi, F.; Alaie, M.; Dabir, B.; Ashjaie, M.

    2001-01-01

    Agitated vessels in form of sti reed tank reactors and mixed ferment ors are being used in large numbers of industry. It is more important to develop good, and theoretically sound models for scaling up and design of agitated vessels. In this article, two phase flow (gas-liquid) in a agitated vessel has been investigated numerically. A two-dimensional computational fluid dynamics model, is used to predict the gas-liquid flow. The effects of gas phase, varying gas flow rates and variation of bubbles shape on flow filed of liquid phase are investigated. The numerical results are verified against the experimental data

  12. Heat treatment device for extending the life of a pressure vessel, particularly a reactor pressure vessel

    International Nuclear Information System (INIS)

    Krauss, P.; Mueller, E.; Poerner, H.; Weber, R.

    1979-01-01

    A support body in the form of an insulating cylinder is tightly sealed by connected surfaces at its outer circumference to the inner wall of the pressure vessel. It forms an annular heating space. The heat treatment or tempering of the pressure vessel takes place with the reactor space empty and screened from the outside by ceiling bolts. Heating gas or an induction winding can be used as the means of heating. (DG) [de

  13. NMR blood vessel imaging method and apparatus

    International Nuclear Information System (INIS)

    Riederer, S.J.

    1988-01-01

    A high speed method of forming computed images of blood vessels based on measurements of characteristics of a body is described comprising the steps of: subjecting a predetermined body area containing blood vessels of interest to, successively, applications of a short repetition time (TR) NMR pulse sequence during the period of high blood velocity and then to corresponding applications during the period of low blood velocity for successive heart beat cycles; weighting the collected imaging data from each application of the NMR pulse sequence according to whether the data was acquired during the period of high blood velocity or a period of low blood velocity of the corresponding heart beat cycle; accumulating weighted imaging data from a plurality of NMR pulse sequences corresponding to high blood velocity periods and from a plurality of NMR pulse sequences corresponding to low blood velocity periods; subtracting the weighted imaging data corresponding to each specific phase encoding acquired during the high blood velocity periods from the weighted imaging data for the same phase encoding corresponding to low blood velocity periods in order to compute blood vessel imaging data; and forming an image of the blood vessels of interest from the blood vessel imaging data

  14. A Laser Metrology/Viewing System for ITER In-Vessel Inspection

    International Nuclear Information System (INIS)

    Spampinato, P.T.; Barry, R.E.; Chesser, J.B.; Menon, M.M.; Dagher, M.A.; Slotwinski, A.

    1997-10-01

    This paper identifies the requirements for a remotely operated precision laser ranging system for the International Thermonuclear Experimental Reactor. The inspection system is used for metrology and viewing, and must be capable of achieving submillimeter accuracy and operation in a reactor vessel that has high gamma radiation, high vacuum, elevated temperature, and magnetic field levels. A coherent, frequency modulated laser radar system is under development to meet these requirements. The metrology/viewing sensor consists of a compact laser-optic module linked through fiberoptics to the laser source and imaging units, located outside the harsh environment. The deployment mechanism is a remotely operated telescopic mast. Gamma irradiation up to 10 7 Gy was conducted on critical sensor components with no significant impact to data transmission, and analysis indicates that critical sensor components can operate in a magnetic field with certain design modifications. Plans for testing key components in a magnetic field are underway

  15. A laser metrology/viewing system for ITER in-vessel inspection

    International Nuclear Information System (INIS)

    Spampinato, P.T.; Barry, R.E.; Chesser, J.B.; Herndon, J.N.; Menon, M.M.; Slotwinski, A.; Dagher, M.A.; Yuen, J.L.

    1998-01-01

    This paper identifies the requirements for the International Thermonuclear Experimental Reactor metrology and viewing system, and describes a remotely operated precision surface mapping system. A metrology system capable of achieving sub-millimeter accuracy must operate in a reactor vessel that has high gamma radiation, high vacuum, elevated temperature, and magnetic field. A coherent, frequency modulated laser radar system is under development to meet these requirements. The metrology/viewing sensor consists of a compact laser optics module linked through fiber optics to the laser source and imaging units, located outside the harsh environment. The deployment mechanism is a remotely operated telescopic-mast. Gamma irradiation to 10 7 Gy was conducted on critical sensor components at Oak Ridge National Laboratory, with no significant impact to data transmission, and analysis indicates that critical sensor components can operate in a magnetic field with certain design modifications. Plans for testing key components in a magnetic field are underway. (orig.)

  16. Dismantling id the reactor pressure vessel insulation and dissecting of the MZFR reactor pressure vessel

    International Nuclear Information System (INIS)

    Loeb, Andreas; Stanke, Dieter; Thoma, Markus; Eisenmann, Beata; Prechtl, Erwin; Dehnke, Burckhard

    2008-01-01

    The MZFR reactor was decommissioned in 1984. The authors describe the dismantling of the reactor pressure vessel insulation that consists of asbestos containing mineral fiber wool. The appropriate remote handling and cutting tools had to be adapted with respect to the restrained space in the containment. The dismantling of the reactor pressure vessel has been completed, the dissected parts have been packaged into 200 containers for the final repository Konrad. During the total project time no reportable events and no damage to persons occurred.

  17. Embrittlement and annealing of reactor pressure vessel steels: comparison of BR3 surveillance and vessel plates to the surrogate plates representative of the Yankee Rowe vessel

    International Nuclear Information System (INIS)

    Fabry, A.; Chaouadi, T.; Puzzolante, J.L.; Van de Velde, J.; Biemiller, E.C.; Rossinski, S.T.; Carter, R.G.

    1996-07-01

    The sister pressure vessels at the BR3 and Rowe Yankee PWR plants were operated at a lower-than-usual temperature (260 degrees Celsius) and their plates were austenitized at higher-than-usual temperature (970 degrees Celsius). A heat tratemement leading to a coarser microstructure than typical for the fine grain plates that are considered in development of USNRC Regulatory guide 1.99. This material displayed outlier behaviour charackterized by a 41J CVN-shift significantly larger than predicted by Regulatory Guide 1.99. Because lower radiation temperature and nickell alloying are generally considered detrimental to irradiation sensitivity, there was a major concern that the nickel-modified lower Rowe plate and the nickel-modified BR3 plate may become too embrittled to satisfy the toughness requirements enbodied in the PTS screening criterion. This paper compares three complementary studies undertaken to clarify these uncertainties: 1) the accelerated irradiation and test program launched in 1990 by Yankee Atomic Electric Company using typical vessel plate materials containing 0.24% copper at two nickel levels: YA1, 0.63% (A533-B) and YA9, 0.19% (A302-B). These were heat-treated to produce the coarse and fine grain microstructures representative of the Yankee/BR3 and the Regulatory Guide plates, respectively, 2) the BR3 surveillance and vessel testing program: this vessel was wet-annealed in 1984, relicensed for operation till the plant shutdown in 1987, ANCL was trepanned in early 1995, 3) the accelerated irradiations in the Belgian BR2 test reactor of the Yankee coarse grain plates YA1 and YA9 together with BR3 vessel specimens extracted at nozzle elevation, a location with negligible radiation exposure. It is shown that the PTS screening criterion was never attained by the BR3 and Rowe plates, and that the BR3 vessel anneal was neither necessary nor sufficient. Finally, the sensitivity of embrittlement, annealing and post-annealing reembrittlement to irradiation

  18. Embrittlement and annealing of reactor pressure vessel steels: comparison of BR3 surveillance and vessel plates to the surrogate plates representative of the Yankee Rowe vessel

    Energy Technology Data Exchange (ETDEWEB)

    Fabry, A.; Chaouadi, T.; Puzzolante, J.L.; Van de Velde, J. [Centre de l``Etude de l``Energie Nucleaire, Mol (Belgium); Biemiller, E.C. [Yankee Atomic Electric Company, Bolton (United States); Rossinski, S.T.; Carter, R.G. [Electric Power Research Institute, Charlotte (United States)

    1996-07-01

    The sister pressure vessels at the BR3 and Rowe Yankee PWR plants were operated at a lower-than-usual temperature (260 degrees Celsius) and their plates were austenitized at higher-than-usual temperature (970 degrees Celsius). A heat tratemement leading to a coarser microstructure than typical for the fine grain plates that are considered in development of USNRC Regulatory guide 1.99. This material displayed outlier behaviour charackterized by a 41J CVN-shift significantly larger than predicted by Regulatory Guide 1.99. Because lower radiation temperature and nickell alloying are generally considered detrimental to irradiation sensitivity, there was a major concern that the nickel-modified lower Rowe plate and the nickel-modified BR3 plate may become too embrittled to satisfy the toughness requirements enbodied in the PTS screening criterion. This paper compares three complementary studies undertaken to clarify these uncertainties: 1) the accelerated irradiation and test program launched in 1990 by Yankee Atomic Electric Company using typical vessel plate materials containing 0.24% copper at two nickel levels: YA1, 0.63% (A533-B) and YA9, 0.19% (A302-B). These were heat-treated to produce the coarse and fine grain microstructures representative of the Yankee/BR3 and the Regulatory Guide plates, respectively, 2) the BR3 surveillance and vessel testing program: this vessel was wet-annealed in 1984, relicensed for operation till the plant shutdown in 1987, ANCL was trepanned in early 1995, 3) the accelerated irradiations in the Belgian BR2 test reactor of the Yankee coarse grain plates YA1 and YA9 together with BR3 vessel specimens extracted at nozzle elevation, a location with negligible radiation exposure. It is shown that the PTS screening criterion was never attained by the BR3 and Rowe plates, and that the BR3 vessel anneal was neither necessary nor sufficient. Finally, the sensitivity of embrittlement, annealing and post-annealing reembrittlement to irradiation

  19. A mobile robot with parallel kinematics constructed under requirements for assembling and machining of the ITER vacuum vessel

    International Nuclear Information System (INIS)

    Pessi, P.; Huapeng Wu; Handroos, H.; Jones, L.

    2006-01-01

    ITER sectors require more stringent tolerances ± 5 mm than normally expected for the size of structure involved. The walls of ITER sectors are made of 60 mm thick stainless steel and are joined together by high efficiency structural and leak tight welds. In addition to the initial vacuum vessel assembly, sectors may have to be replaced for repair. Since commercially available machines are too heavy for the required machining operations and the lifting of a possible e-beam gun column system, and conventional robots lack the stiffness and accuracy in such machining condition, a new flexible, lightweight and mobile robotic machine is being considered. For the assembly of the ITER vacuum vessel sector, precise positioning of welding end-effectors, at some distance in a confined space from the available supports, will be required, which is not possible using conventional machines or robots. This paper presents a special robot, able to carry out welding and machining processes from inside the ITER vacuum vessel, consisting of a ten-degree-of-freedom parallel robot mounted on a carriage driven by electric motor/gearbox on a track. The robot consists of a Stewart platform based parallel mechanism. Water hydraulic cylinders are used as actuators to reach six degrees of freedom for parallel construction. Two linear and two rotational motions are used for enlargement the workspace of the manipulator. The robot carries both welding gun such as a TIG, hybrid laser or e-beam welding gun to weld the inner and outer walls of the ITER vacuum vessel sectors and machining tools to cut and milling the walls with necessary accuracy, it can also carry other tools and material to a required position inside the vacuum vessel . For assembling an on line six degrees of freedom seam finding algorithm has been developed, which enables the robot to find welding seam automatically in a very complex environment. In the machining multi flexible machining processes carried out automatically by

  20. Maury Journals - German Vessels

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — German vessels observations, after the 1853 Brussels Conference that set International Maritime Standards, modeled after Maury Marine Standard Observations.

  1. Vessel dilatation in coronary angiograms

    International Nuclear Information System (INIS)

    Hinterauer, L.; Goebel, N.

    1983-01-01

    Amongst 166 patients with aneurysms, ectasia or megaloarteries shown on coronary angiograms, 86.1% had dilated vessels as part of generalised coronary sclerosis (usually in patients with three-vessel disease). In 9%, dilatation was of iatrogenic origin and in 4.8% it was idiopathic. One patient had Marfan's syndrome. Amongst 9 000 patients, there were eight with megalo-arteries without stenosis; six of these had atypical angina and three suffered an infarct. Patients with definite dilatation of the coronary artery and stagnation of contrast flow required treatment. (orig.) [de

  2. Vessel dilatation in coronary angiograms

    Energy Technology Data Exchange (ETDEWEB)

    Hinterauer, L.; Goebel, N.

    1983-11-01

    Amongst 166 patients with aneurysms, ectasia or megaloarteries shown on coronary angiograms, 86.1% had dilated vessels as part of generalised coronary sclerosis (usually in patients with three-vessel disease). In 9%, dilatation was of iatrogenic origin and in 4.8% it was idiopathic. One patient had Marfan's syndrome. Amongst 9 000 patients, there were eight with megalo-arteries without stenosis; six of these had atypical angina and three suffered an infarct. Patients with definite dilatation of the coronary artery and stagnation of contrast flow required treatment.

  3. Diagnostic accuracy of contrast-enhanced MR angiography and unenhanced proton MR imaging compared with CT pulmonary angiography in chronic thromboembolic pulmonary hypertension

    Energy Technology Data Exchange (ETDEWEB)

    Rajaram, Smitha [Unit of Academic Radiology, University of Sheffield, Sheffield (United Kingdom); Academic Unit of Radiology, C Floor, Royal Hallamshire Hospital, Sheffield (United Kingdom); Swift, Andrew J.; Wild, Jim M. [Unit of Academic Radiology, University of Sheffield, Sheffield (United Kingdom); Sheffield Cardiovascular Biomedical Research Unit, Sheffield (United Kingdom); Capener, David; Telfer, Adam [Unit of Academic Radiology, University of Sheffield, Sheffield (United Kingdom); Davies, Christine; Hill, Catherine [Sheffield Teaching Hospitals Trust, Department of Radiology, Sheffield (United Kingdom); Condliffe, Robin; Elliot, Charles; Kiely, David G. [Sheffield Pulmonary Vascular Disease Unit, Royal Hallamshire Hospital, Sheffield Teaching Hospitals NHS Foundation Trust, Sheffield (United Kingdom); Sheffield Cardiovascular Biomedical Research Unit, Sheffield (United Kingdom); Hurdman, Judith [Sheffield Pulmonary Vascular Disease Unit, Royal Hallamshire Hospital, Sheffield Teaching Hospitals NHS Foundation Trust, Sheffield (United Kingdom)

    2012-02-15

    To evaluate the diagnostic accuracy of contrast-enhanced MR angiography (CE-MRA) and the added benefit of unenhanced proton MR angiography compared with CT pulmonary angiography (CTPA) in patients with chronic thromboembolic disease (CTE). A 2 year retrospective study of 53 patients with chronic thromboembolic pulmonary hypertension who underwent CTPA and MRI for suspected pulmonary hypertension and a control group of 36 patients with no CT evidence of pulmonary embolism. The MRI was evaluated for CTE and the combined diagnostic accuracy of ce-MRA and unenhanced proton MRA was determined. CE-MRA generated lung perfusion maps were also assessed. The overall sensitivity and specificity of CE-MRA in diagnosing proximal and distal CTE were 98% and 94%, respectively. The sensitivity improved from 50% to 88% for central vessel disease when CE-MRA images were analysed with unenhanced proton MRA. The CE-MRA identified more stenoses (29/18), post-stenosis dilatation (23/7) and occlusions (37/29) compared with CTPA. The CE-MRA perfusion images showed a sensitivity of 92% for diagnosing CTE. CE-MRA has high sensitivity and specificity for diagnosing CTE. The sensitivity of CE-MRA for visualisation of adherent central and lobar thrombus significantly improves with the addition of unenhanced proton MRA which delineates the vessel wall. (orig.)

  4. Diagnostic accuracy of contrast-enhanced MR angiography and unenhanced proton MR imaging compared with CT pulmonary angiography in chronic thromboembolic pulmonary hypertension

    International Nuclear Information System (INIS)

    Rajaram, Smitha; Swift, Andrew J.; Wild, Jim M.; Capener, David; Telfer, Adam; Davies, Christine; Hill, Catherine; Condliffe, Robin; Elliot, Charles; Kiely, David G.; Hurdman, Judith

    2012-01-01

    To evaluate the diagnostic accuracy of contrast-enhanced MR angiography (CE-MRA) and the added benefit of unenhanced proton MR angiography compared with CT pulmonary angiography (CTPA) in patients with chronic thromboembolic disease (CTE). A 2 year retrospective study of 53 patients with chronic thromboembolic pulmonary hypertension who underwent CTPA and MRI for suspected pulmonary hypertension and a control group of 36 patients with no CT evidence of pulmonary embolism. The MRI was evaluated for CTE and the combined diagnostic accuracy of ce-MRA and unenhanced proton MRA was determined. CE-MRA generated lung perfusion maps were also assessed. The overall sensitivity and specificity of CE-MRA in diagnosing proximal and distal CTE were 98% and 94%, respectively. The sensitivity improved from 50% to 88% for central vessel disease when CE-MRA images were analysed with unenhanced proton MRA. The CE-MRA identified more stenoses (29/18), post-stenosis dilatation (23/7) and occlusions (37/29) compared with CTPA. The CE-MRA perfusion images showed a sensitivity of 92% for diagnosing CTE. CE-MRA has high sensitivity and specificity for diagnosing CTE. The sensitivity of CE-MRA for visualisation of adherent central and lobar thrombus significantly improves with the addition of unenhanced proton MRA which delineates the vessel wall. (orig.)

  5. Completely integrated prestressed-concrete reactor pressure vessel, type 'Star'

    International Nuclear Information System (INIS)

    Neunert, B.; Jueptner, G.; Kumpf, H.

    1975-01-01

    The star support vessel is suitable for the connection to all primary circuit systems consisting of a main vessel and a number of satellite vessels around and connected to it, i.e. for LWR, HTR and process reactor. It must be made clear, however, that the PWR in particular with its components does not appear to be suited for the optimum incorporation in a prestressed-concrete pressure vessel system, no matter what kind. There are clear concepts about modifications which, however, require considerable development expenditure. (orig./LH) [de

  6. Device of supporting a vacuum plasma vessel

    International Nuclear Information System (INIS)

    Kanoi, Minoru; Hori, Yasuro.

    1980-01-01

    Purpose: To improve the earthquake-resistance of a vacuum plasma vessel by equalizing the natural vibrations of a vibrating system formed by supporting mechanisms of the respective sectors of the vessel. Constitution: The vacuum plasma vessel is constructed of bellows interposed among a plurality of thick sector-like rings and the rings, which are respectively supported by supporting mechanisms. Thus, the vibrating systems are divided into the rings interposed with the bellows, arms as the supporting mechanisms, and posts. The natural vibrations of these vibrating systems are equalized to each other by suitably adjusting the configurations and the sized of the arms and the posts or the weight or the like of the rings. Therefore, the respective rings become vibrated at the natural vibrations equal to each other so as to largely reduce the stresses produced at both ends of the bellows. Accordingly, it can remarkably improve the earthquake-resistance of the entire plasma vessel. (Sekiya, K.)

  7. Initial conditioning of the TFTR vacuum vessel

    International Nuclear Information System (INIS)

    Dylla, H.F.; Blanchard, W.R.; Krawchuk, R.B.; Hawryluk, R.J.; Owens, D.K.

    1984-01-01

    We report on the initial conditioning of the Tokamak Fusion Test Reactor (TFTR) vacuum vessel prior to the initiation of first plasma discharges, and during subsequent operation with high power ohmically-heated plasmas. Following evacuation of the 86 m 3 vessel with the 10 4 1/s high vacuum pumping system, the vessel was conditioned by a 15 A dc glow discharge in H 2 at a pressure of 5 mTorr. Rapid-pulse discharge cleaning was used subsequently to preferentially condition the graphite plasma limiters. The effectiveness of the discharge cleaning was monitored by measuring the exhaust rates of the primary discharge products (CO/C 2 H 4 , CH 4 , and H 2 O). After 175 hours of glow discharge treatment, the equivalent of 50 monolayers of C and O was removed from the vessel, and the partial pressures of impurity gases were reduced to the range of 10 -9 -10 -10 Torr

  8. Wine vessels (Vasa vinaria in roman law

    Directory of Open Access Journals (Sweden)

    Aličić Samir

    2017-01-01

    Full Text Available The notion of 'wine vessels' in Roman law comprises all the winecontaining recipients. There is no legal standardization of wine vessels by means of volume, and although the terms amphora, urna and culleus are used to designate both the vessels and the units of measure, these are two different meanings of the terms. In regard of the question, whether the vessels make appurtenance of the wine, jurisprudents of proculean school divided them in two categories. In the first category are those that follow legal status of wine, usually amphoras and other jars (cadi which are used for 'packaging', i. e. 'bottling' of the wine. The second category make mostly vats (cuppae and ceramic cisterns (dolia, which don't follow legal status of wine, making instead part of farming equipment of a landed property (instrumentum fundi and it's appurtenance. But, the roman jurists are not consistent regarding criteria for distinguishing these two categories.

  9. Flange surface detection device for upper lid of reactor pressure vessel

    International Nuclear Information System (INIS)

    Kobayashi, Teruo.

    1996-01-01

    The present invention provide a device for detecting a flatness of an O-ring groove formed on a flange surface simply and at a high accuracy in a state where the upper lid of a reactor pressure vessel is removed as it is. Namely, a running truck provided with magnetic wheels is caused to run while being adsorbed along the outer circumferential surface of a downward flange surface and the lower surface of the flange in a state where the upper lid is removed. A sensor attaching stand equipped with spring-biased wheels is mounted to the running truck. The sensor attaching stand is provided with a flange surface sensor for measuring the distance to the lower surface of the flange and a groove sensor for measuring the distance to the bottom surface of an O-ring groove. Relative displacement of the groove sensor is determined by a calculator based on the measured value on the flange surface sensor. A flatness is obtained from the maximum value and the minimum value. In addition, presence of flaws on the bottom surface of the groove is detected based on the relative change of both measured values at the same time. As a result, all of the errors caused by the running are off-set thereby capable of performing a measurement at high accuracy. (I.S.)

  10. In-place thermal annealing of nuclear reactor pressure vessels

    International Nuclear Information System (INIS)

    Server, W.L.

    1985-04-01

    Radiation embrittlement of ferritic pressure vessel steels increases the ductile-brittle transition temperature and decreases the upper shelf level of toughness as measured by Charpy impact tests. A thermal anneal cycle well above the normal operating temperature of the vessel can restore most of the original Charpy V-notch energy properties. The Amry SM-1A test reactor vessel was wet annealed in 1967 at less than 343 0 C (650 0 F), and wet annealing of the Belgian BR-3 reactor vessel at 343 0 C (650 0 F) has recently taken place. An industry survey indicates that dry annealing a reactor vessel in-place at temperatures as high as 454 0 C (850 0 F) is feasible, but solvable engineering problems do exist. Economic considerations have not been totally evaluated in assessing the cost-effectiveness of in-place annealing of commercial nuclear vessels. An American Society for Testing and Materials (ASTM) task group is upgrading and revising guide ASTM E 509-74 with emphasis on the materials and surveillance aspects of annealing rather than system engineering problems. System safety issues are the province of organizations other than ASTM (e.g., the American Society of Mechanical Engineers Boiler and Pressure Vessel Code body)

  11. OCA-P, PWR Vessel Probabilistic Fracture Mechanics

    International Nuclear Information System (INIS)

    Cheverton, R.D.; Ball, D.G.

    2001-01-01

    1 - Description of program or function: OCA-P is a probabilistic fracture-mechanics code prepared specifically for evaluating the integrity of pressurized-water reactor vessels subjected to overcooling-accident loading conditions. Based on linear-elastic fracture mechanics, it has two- and limited three-dimensional flaw capability, and can treat cladding as a discrete region. Both deterministic and probabilistic analyses can be performed. For deterministic analysis, it is possible to conduct a search for critical values of the fluence and the nil-ductility reference temperature corresponding to incipient initiation of the initial flaw. The probabilistic portion of OCA-P is based on Monte Carlo techniques, and simulated parameters include fluence, flaw depth, fracture toughness, nil-ductility reference temperature, and concentrations of copper, nickel, and phosphorous. Plotting capabilities include the construction of critical-crack-depth diagrams (deterministic analysis) and a variety of histograms (probabilistic analysis). 2 - Method of solution: OAC-P accepts as input the reactor primary- system pressure and the reactor pressure-vessel downcomer coolant temperature, as functions of time in the specified transient. Then, the wall temperatures and stresses are calculated as a function of time and radial position in the wall, and the fracture-mechanics analysis is performed to obtain the stress intensity factors as a function of crack depth and time in the transient. In a deterministic analysis, values of the static crack initiation toughness and the crack arrest toughness are also calculated for all crack depths and times in the transient. A comparison of these values permits an evaluation of flaw behavior. For a probabilistic analysis, OCA-P generates a large number of reactor pressure vessels, each with a different combination of the various values of the parameters involved in the analysis of flaw behavior. For each of these vessels, a deterministic fracture

  12. Maury Journals - US Vessels

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — U.S. vessels observations, after the 1853 Brussels Conference that set International Maritime Standards, modeled after Maury Marine Standard Observations.

  13. Heat load imposed on reactor vessels during in-vessel retention of core melts

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Su-Hyeon; Chung, Bum-Jin, E-mail: bjchung@khu.ac.kr

    2016-11-15

    Highlights: • Angular heat load on reactor vessel by natural convection of oxide pool was measured. • High Ra was achieved by using mass transfer experiments based on analogy concept. • Measured Nusselt numbers agreed reasonably with the other existing studies. • Three different types of volumetric heat sources were compared. • They didn’t affect the heat flux of the top plate but affected those of the reactor vessel. - Abstract: We measured the heat load imposed on reactor vessels by natural convection of the oxide pool in severe accidents. Based on the analogy between heat and mass transfer, mass transfer experiments were performed using a copper sulfate electroplating system. A modified Rayleigh number of the order 10{sup 14} was achieved in a small facility with a height of 0.1 m. Three different types of volumetric heat sources were compared and the average Nusselt number of the curved surface was 39% lower, whereas in the case of the top plate was 6% higher than in previous studies with a two-dimensional geometry due to the high Sc value of this study. Reliable experimental data on the angular heat flux ratios were reported compared to those of the BALI and SIGMA CP facilities in terms of fluctuations and consistency.

  14. Thermal annealing of an embrittled reactor pressure vessel

    International Nuclear Information System (INIS)

    Mager, T.R.; Dragunov, Y.G.; Leitz, C.

    1998-01-01

    As a result of the popularity of the Agencies report 'Neutron Irradiation Embrittlement of Reactor Pressure Vessel Steels' of 1975, it was decided that another report on this broad subject would be of use. In this report, background and contemporary views on specially identified areas of the subject are considered as self-contained chapters, written by experts. Chapter 11 deals with thermal annealing of an embrittled reactor pressure vessel. Anneal procedures for vessels from both the US and the former USSR are mentioned schematically, wet anneals at lower temperature and dry anneals above RPV design temperatures are investigated. It is shown that heat treatment is a means of recovering mechanical properties which were degraded by neutron radiation exposure, thus assuring reactor pressure vessel compliance with regulatory requirements

  15. Diagnostic accuracy and measurement sensitivity of digital models for orthodontic purposes: A systematic review.

    Science.gov (United States)

    Rossini, Gabriele; Parrini, Simone; Castroflorio, Tommaso; Deregibus, Andrea; Debernardi, Cesare L

    2016-02-01

    Our objective was to assess the accuracy, validity, and reliability of measurements obtained from virtual dental study models compared with those obtained from plaster models. PubMed, PubMed Central, National Library of Medicine Medline, Embase, Cochrane Central Register of Controlled Clinical trials, Web of Knowledge, Scopus, Google Scholar, and LILACs were searched from January 2000 to November 2014. A grading system described by the Swedish Council on Technology Assessment in Health Care and the Cochrane tool for risk of bias assessment were used to rate the methodologic quality of the articles. Thirty-five relevant articles were selected. The methodologic quality was high. No significant differences were observed for most of the studies in all the measured parameters, with the exception of the American Board of Orthodontics Objective Grading System. Digital models are as reliable as traditional plaster models, with high accuracy, reliability, and reproducibility. Landmark identification, rather than the measuring device or the software, appears to be the greatest limitation. Furthermore, with their advantages in terms of cost, time, and space required, digital models could be considered the new gold standard in current practice. Copyright © 2016 American Association of Orthodontists. Published by Elsevier Inc. All rights reserved.

  16. 46 CFR 105.90-1 - Existing commercial fishing vessels dispensing petroleum products.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 4 2010-10-01 2010-10-01 false Existing commercial fishing vessels dispensing petroleum... AND MISCELLANEOUS VESSELS COMMERCIAL FISHING VESSELS DISPENSING PETROLEUM PRODUCTS Existing Commercial Fishing Vessels Dispensing Petroleum Products § 105.90-1 Existing commercial fishing vessels dispensing...

  17. Lining up device for the internal structures of a nuclear reactor vessel

    International Nuclear Information System (INIS)

    Silverblatt, B.L.

    1977-01-01

    The invention concerns a nuclear reactor of the type with a vessel, a vessel head carried at the top of this vessel by a core cylinder comprising a flange internally supported by the vessel, and an upper support structure supported between the core cylinder flange and the vessel head to align laterally the head, vessel, flange and support structure. A bottom key device is provided for lining up the flange, support structure and vessel, and an upper key device for laterally lining up support structure and the vessel head and for maintaining this alignment when they are removed simultaneously from the core cylinder and vessel. When re-assembling the reactor, the top support structure and the vessel head are lowered simultaneously so that an opening in the top alignment structure engages in the upper extension of the bottom alignment structure. A plurality of alignment stuctures may be utilised round the circumference of the reactor vessel. The disposition of the invention also facilitates the removal of the core cylinder from the reactor vessel. In this way, the alignment on re-assembly is ensured by the re-entry of the bottom extension under the flange of the core cylinder with the groove or keyway of the reactor vessel [fr

  18. Accuracy of estimation of graft size for living-related liver transplantation: first results of a semi-automated interactive software for CT-volumetry.

    Directory of Open Access Journals (Sweden)

    Theresa Mokry

    Full Text Available To evaluate accuracy of estimated graft size for living-related liver transplantation using a semi-automated interactive software for CT-volumetry.Sixteen donors for living-related liver transplantation (11 male; mean age: 38.2±9.6 years underwent contrast-enhanced CT prior to graft removal. CT-volumetry was performed using a semi-automated interactive software (P, and compared with a manual commercial software (TR. For P, liver volumes were provided either with or without vessels. For TR, liver volumes were provided always with vessels. Intraoperative weight served as reference standard. Major study goals included analyses of volumes using absolute numbers, linear regression analyses and inter-observer agreements. Minor study goals included the description of the software workflow: degree of manual correction, speed for completion, and overall intuitiveness using five-point Likert scales: 1--markedly lower/faster/higher for P compared with TR, 2--slightly lower/faster/higher for P compared with TR, 3--identical for P and TR, 4--slightly lower/faster/higher for TR compared with P, and 5--markedly lower/faster/higher for TR compared with P.Liver segments II/III, II-IV and V-VIII served in 6, 3, and 7 donors as transplanted liver segments. Volumes were 642.9±368.8 ml for TR with vessels, 623.8±349.1 ml for P with vessels, and 605.2±345.8 ml for P without vessels (P<0.01. Regression equations between intraoperative weights and volumes were y = 0.94x+30.1 (R2 = 0.92; P<0.001 for TR with vessels, y = 1.00x+12.0 (R2 = 0.92; P<0.001 for P with vessels, and y = 1.01x+28.0 (R2 = 0.92; P<0.001 for P without vessels. Inter-observer agreement showed a bias of 1.8 ml for TR with vessels, 5.4 ml for P with vessels, and 4.6 ml for P without vessels. For the degree of manual correction, speed for completion and overall intuitiveness, scale values were 2.6±0.8, 2.4±0.5 and 2.CT-volumetry performed with P can predict accurately graft

  19. Reactor pressure vessel support

    International Nuclear Information System (INIS)

    Butti, J.P.

    1977-01-01

    A link and pin support system provides the primary vertical and lateral support for a nuclear reactor pressure vessel without restricting thermally induced radial and vertical expansion and contraction. (Auth.)

  20. Vacuum vessels for the LHC magnets arrive at CERN

    CERN Multimedia

    2001-01-01

    The first batch of pre-series vacuum vessels for the LHC dipole magnets has just been delivered to CERN. The vessels are components of the cryostats and will provide the thermal insulation for the superconducting magnets. The first batch of vacuum vessels for the LHC dipole magnets with the team taking part at CERN in ordering and installing them. Left to right : Claude Hauviller, Monique Dupont, Lloyd Williams, Franck Gavin, Alain Jacob, Christophe Vuitton, Davide Bozzini, Laure Sandri, Mikael Sjoholm and André de Saever. In 2006 all that will be seen of the LHC superconducting dipoles in the LHC tunnel will be a line of over 1230 blue cylindrical vacuum vessels. Ten vessels, each weighing 4 tonnes, are already at CERN. On 6 July the first batch of pre-series vessels reached the Lab-oratory from the firm SIMIC Spa whose works are near Savona in north-western Italy. Despite appearances, these 15-metre long, 1-metre diameter blue tubes are much more sophisticated than sections of a run-of-the-mill...

  1. ITER vacuum vessel dynamic stress analysis of a disruption

    International Nuclear Information System (INIS)

    Riemer, B.W.; Conner, D.L.; Strickler, D.J.; Williamson, D.E.

    1994-01-01

    Dynamic stress analysis of the International Thermonuclear Experimental Reactor vacuum vessel loaded by disruption forces was performed. The deformation and stress results showed strong inertial effects when compared to static analyses. Maximum stress predicted dynamically was 300 MPa, but stress shown by static analysis from loads at the same point in time reached only 80 MPa. The analysis also provided a reaction load history in the vessel's supports which is essential in evaluating support design. The disruption forces were estimated by assuming a 25-MA plasma current decaying at 1 MA/ms while moving vertically. In addition to forces developed within the vessel, vertical loadings from the first wall/strong back assemblies and the divertor were applied to the vessel at their attachment points. The first 50 natural modes were also determined. The first mode's frequency was 6.0 Hz, and its shape is characterized by vertical displacement of the vessel inner leg. The predicted deformation of the vessel appeared similar to its first mode shape combined with radial contraction. Kinetic energy history from the analysis also correlated with the first mode frequency

  2. Light-water reactor pressure vessel surveillance standards

    International Nuclear Information System (INIS)

    Anon.

    1981-01-01

    The master matrix standard describes a series of standard practices, guides, and methods for the prediction of neutron-induced changes in light-water reactor (LWR) pressure vessel steels throughout a pressure vessel's service life. Some of these are existing American Society for Testing and Materials (ASTM) standards, some are ASTM standards that have been modified, and some are newly proposed ASTM standards. The current (1) scope, (2) areas of application, (3) interrelationships, and (4) status and time table of development, improvement, validation, and calibration for a series of 16 ASTM standards are defined. The standard also includes a discussion of LWR pressure vessel surveillance - justification, requirements, and status of work

  3. 46 CFR 105.05-1 - Commercial fishing vessels dispensing petroleum products.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 4 2010-10-01 2010-10-01 false Commercial fishing vessels dispensing petroleum products... MISCELLANEOUS VESSELS COMMERCIAL FISHING VESSELS DISPENSING PETROLEUM PRODUCTS Application § 105.05-1 Commercial fishing vessels dispensing petroleum products. (a) The provisions of this part, with the exception of...

  4. Leak detection device for nuclear reactor pressure vessel

    International Nuclear Information System (INIS)

    Ikeda, Jun.

    1988-01-01

    Purpose: To test the leakage of a nuclear reactor pressure vessel during stopping for a short period of time with no change to the pressure vessel itself. Constitution: The device of the present invention comprises two O-rings disposed on the flange surface that connects a pressure vessel main body and an upper cover, a leak-off pipeway derived from the gap of the O-rings at the flange surface to the outside of the pressure vessel, a pressure detection means connected to the end of the pipeway, a humidity detection means disposed to the lead-off pipeway, a humidity detection means disposed to the lead-off pipeway, and gas supply means and gas suction means disposed each by way of a check valve to a side pipe branched from the pipeway. After stopping the operation of the nuclear reactor and pressurizing the pressure vessel by filling water, gases supplied to the gap between the O-rings at the flange surface by opening the check valve. In a case where water in the pressure vessel should leak to the flange surface, when gas suction is applied by properly opening the check valve, increase in the humidity due to the steams of leaked water diffused into the gas is detected to recognize the occurrence of leakage. (Kamimura, M.)

  5. Radiation embrittlement of Spanish nuclear reactor pressure vessel steels

    International Nuclear Information System (INIS)

    Bros, J.; Ballesteros, A.; Lopez, A.

    1993-01-01

    Commercial pressurized water reactor (PWR) and boiling water reactor (BWR) nuclear power plants contain a series of pressure vessel steel surveillance capsules as the principal means of monitoring radiation effects on the pressure vessel. Changes in fracture toughness are more severe in surveillance capsules than in reactor vessel materials because of their proximity of the reactor core. Therefore, it is possible to predict changes in fracture toughness of the reactor vessel materials. This paper describes the status of the reactor vessel surveillance program relating to Spanish nuclear power plants. To date, twelve capsules have been removed and analyzed from seven of the nine Spanish reactors in operation. The results obtained from the analysis of these capsules are compared with the predictions of the Nuclear Regulatory Commission (NRC) Regulatory Guide 1.99, Rev. 2, by means of measured and expected increase of the nil-ductility transition reference temperature (RT NDT ). The comparison is made considering the different variables normally included in the studies of radiation response of reactor pressure vessel materials, such as copper content of steel, level of neutron fluence above 1 MeV, base metal or weld metal, and so forth. The surveillance data have been used for determining the adjusted reference temperatures and upper shelf energies at any time. The results have shown that the seven pressure vessels are in excellent condition to continue operating with safety against brittle fracture beyond the design life, without the need to recuperate the degraded properties of the materials by annealing of the vessel

  6. Diaphragmatic lymphatic vessel behavior during local skeletal muscle contraction.

    Science.gov (United States)

    Moriondo, Andrea; Solari, Eleonora; Marcozzi, Cristiana; Negrini, Daniela

    2015-02-01

    The mechanism through which the stresses developed in the diaphragmatic tissue during skeletal muscle contraction sustain local lymphatic function was studied in 10 deeply anesthetized, tracheotomized adult Wistar rats whose diaphragm was exposed after thoracotomy. To evaluate the direct effect of skeletal muscle contraction on the hydraulic intraluminal lymphatic pressures (Plymph) and lymphatic vessel geometry, the maximal contraction of diaphragmatic fibers adjacent to a lymphatic vessel was elicited by injection of 9.2 nl of 1 M KCl solution among diaphragmatic fibers while Plymph was recorded through micropuncture and vessel geometry via stereomicroscopy video recording. In lymphatics oriented perpendicularly to the longitudinal axis of muscle fibers and located at skeletal muscle contraction (Dmc) decreased to 61.3 ± 1.4% of the precontraction value [resting diameter (Drest)]; however, if injection was at >900 μm from the vessel, Dmc enlarged to 131.1 ± 2.3% of Drest. In vessels parallel to muscle fibers, Dmc increased to 122.8 ± 2.9% of Drest. During contraction, Plymph decreased as much as 22.5 ± 2.6 cmH2O in all submesothelial superficial vessels, whereas it increased by 10.7 ± 5.1 cmH2O in deeper vessels running perpendicular to contracting muscle fibers. Hence, the three-dimensional arrangement of the diaphragmatic lymphatic network seems to be finalized to efficiently exploit the stresses exerted by muscle fibers during the contracting inspiratory phase to promote lymph formation in superficial submesothelial lymphatics and its further propulsion in deeper intramuscular vessels. Copyright © 2015 the American Physiological Society.

  7. Thermal loads on the TJ-II Vacuum Vessel under Neutral Beam Injection

    International Nuclear Information System (INIS)

    Guasp, J.; Fuentes, C.; Liniers, M.

    1996-01-01

    In this study a numerical analysis of power loads on the complex 3D structure of the TJ-II Vacuum Vessel, moderated with reasonable accuracy, under NBI, is done. To do this it has been necessary to modify deeply the DENSB code for power loads in order to include the TJ-II VV wall parts as targets and as beam scrapers, allowing the possibility of self-shadowing. After a short description of the primitive version of the DENSB code (paragraph 2) and of the visualisation code MOVIE(paragraph 3), the DENSB upgrading are described (paragraphs 4,5) and finally the results are presented (paragraph 6). These code modifications and the improving on the visualization tools provide more realistic load evaluations, both with and without plasma, validating former results and showing clearly the VV zones that will need new protections. (Author)

  8. About reliability of WWER pressure vessel neutron fluence calculation

    Energy Technology Data Exchange (ETDEWEB)

    Belousov, S; Ilieva, K; Antonov, S [Bylgarska Akademiya na Naukite, Sofia (Bulgaria). Inst. za Yadrena Izsledvaniya i Yadrena Energetika

    1996-12-31

    This reliability study was carried out under a Research Contracts F111 and TH-324 of the Bulgarian Ministry of Higher Education and the IAEA. The effect of geometry approximation and the choice of neutron cross-sections on the calculation model is estimated. The neutron flux onto reactor pressure vessel at locations, important for metal embrittlement surveillance, has been calculated using the codes TORT and DORT. The flux values calculated for both WWER-440 and WWER-1000 show good consistency within the limits of solution accuracy. It is concluded that the synthesis method (DORT) can be used for calculations at a reasonable cost whenever metal embrittlement surveillance is considered. Using an iron sphere benchmark measurement, a comparison of an experimental leakage spectrum with spectrum calculated using multigroup neutron cross-sections based on ENDF/B-4 and ENDF/B-6 data is performed. In the energy region above 1 MeV the best agreement with the experiment is achieved for ENDF/B-6 in VITAMIN-E group structure. 7 refs., 1 fig., 4 tabs.

  9. About reliability of WWER pressure vessel neutron fluence calculation

    International Nuclear Information System (INIS)

    Belousov, S.; Ilieva, K.; Antonov, S.

    1995-01-01

    This reliability study was carried out under a Research Contracts F111 and TH-324 of the Bulgarian Ministry of Higher Education and the IAEA. The effect of geometry approximation and the choice of neutron cross-sections on the calculation model is estimated. The neutron flux onto reactor pressure vessel at locations, important for metal embrittlement surveillance, has been calculated using the codes TORT and DORT. The flux values calculated for both WWER-440 and WWER-1000 show good consistency within the limits of solution accuracy. It is concluded that the synthesis method (DORT) can be used for calculations at a reasonable cost whenever metal embrittlement surveillance is considered. Using an iron sphere benchmark measurement, a comparison of an experimental leakage spectrum with spectrum calculated using multigroup neutron cross-sections based on ENDF/B-4 and ENDF/B-6 data is performed. In the energy region above 1 MeV the best agreement with the experiment is achieved for ENDF/B-6 in VITAMIN-E group structure. 7 refs., 1 fig., 4 tabs

  10. 19 CFR 4.60 - Vessels required to clear.

    Science.gov (United States)

    2010-04-01

    ... contiguous country otherwise than by sea. (c) Vessels which will merely transit the Panama Canal without... of clearance and related papers shall be surrendered. (e) No vessel shall be cleared for the high...

  11. Multi-purpose deployer for ITER in-vessel maintenance

    Energy Technology Data Exchange (ETDEWEB)

    Choi, Chang-Hwan, E-mail: Chang-Hwan.CHOI@iter.org [ITER Organization, Route de Vinon-sur-Verdon, 13115 St Paul lez Durance (France); Tesini, Alessandro; Subramanian, Rajendran [ITER Organization, Route de Vinon-sur-Verdon, 13115 St Paul lez Durance (France); Rolfe, Alan; Mills, Simon; Scott, Robin; Froud, Tim; Haist, Bernhard; McCarron, Eddie [Oxford Technologies Ltd., 7 Nuffield Way, Abingdon, OXON (United Kingdom)

    2015-10-15

    Highlights: • ITER RH system called as the multi-purpose deployer (MPD) is introduced. • The MPD performs dust and tritium inventory control, in-service inspection. • The MPD performs leak localization, in-vessel diagnostics maintenance. • The MPD has nine degrees of freedom with a payload capacity up to 2 tons. - Abstract: The multi-purpose deployer (MPD) is a general purpose in-vessel remote handling (RH) system in the ITER RH system. The MPD provides the means for deployment and handling of in-vessel tools or components inside the vacuum vessel (VV) for dust and tritium inventory control, in-service inspection, leak localization, and in-vessel diagnostics. It also supports the operation of blanket first wall maintenance and neutral beam duct liner module maintenance operations. This paper describes the concept design of the MPD. The MPD is a cask based system, i.e. it stays in the hot cell building during the machine operation, and is deployed to the VV using the cask system for the in-vessel operations. The main part of the MPD is the articulated transporter which provides transportation and positioning of the in-vessel tools or components. The articulated transporter has nine degrees of freedom with a payload capacity up to 2 tons. The articulated transporter can cover the whole internal surface of the VV by switching between the four equatorial RH ports. Additionally it can use two non-RH equatorial ports to transfer large tools or components. A concept for in-cask tool exchange is developed which minimizes the cask transportation by allowing the MPD to stay in the VV during the tool exchange.

  12. Reactor Vessel and Reactor Vessel Internals Segmentation at Zion Nuclear Power Station - 13230

    Energy Technology Data Exchange (ETDEWEB)

    Cooke, Conrad; Spann, Holger [Siempelkamp Nuclear Services: 5229 Sunset Blvd., (Suite M), West Columbia, SC, 29169 (United States)

    2013-07-01

    Zion Nuclear Power Station (ZNPS) is a dual-unit Pressurized Water Reactor (PWR) nuclear power plant located on the Lake Michigan shoreline, in the city of Zion, Illinois approximately 64 km (40 miles) north of Chicago, Illinois and 67 km (42 miles) south of Milwaukee, Wisconsin. Each PWR is of the Westinghouse design and had a generation capacity of 1040 MW. Exelon Corporation operated both reactors with the first unit starting production of power in 1973 and the second unit coming on line in 1974. The operation of both reactors ceased in 1996/1997. In 2010 the Nuclear Regulatory Commission approved the transfer of Exelon Corporation's license to ZionSolutions, the Long Term Stewardship subsidiary of EnergySolutions responsible for the decommissioning of ZNPS. In October 2010, ZionSolutions awarded Siempelkamp Nuclear Services, Inc. (SNS) the contract to plan, segment, remove, and package both reactor vessels and their respective internals. This presentation discusses the tools employed by SNS to remove and segment the Reactor Vessel Internals (RVI) and Reactor Vessels (RV) and conveys the recent progress. SNS's mechanical segmentation tooling includes the C-HORCE (Circumferential Hydraulically Operated Cutting Equipment), BMT (Bolt Milling Tool), FaST (Former Attachment Severing Tool) and the VRS (Volume Reduction Station). Thermal segmentation of the reactor vessels will be accomplished using an Oxygen- Propane cutting system. The tools for internals segmentation were designed by SNS using their experience from other successful reactor and large component decommissioning and demolition (D and D) projects in the US. All of the designs allow for the mechanical segmentation of the internals remotely in the water-filled reactor cavities. The C-HORCE is designed to saw seven circumferential cuts through the Core Barrel and Thermal Shield walls with individual thicknesses up to 100 mm (4 inches). The BMT is designed to remove the bolts that fasten the Baffle

  13. Accuracy and role of contrast-enhanced CT in diagnosis and surgical planning in 88 soft tissue tumours of extremities

    International Nuclear Information System (INIS)

    Verga, Lucia; Robiati, Sara; De Marchi, Armanda; Martorano, Domenico; Faletti, Carlo; Brach del Prever, Elena Maria; Linari, Alessandra; Boffano, Michele; Piana, Raimondo

    2016-01-01

    Soft tissue tumours (STT) require accurate diagnosis in order to identify potential malignancies. Preoperative planning is fundamental to avoid inadequate treatments. The role of contrast-enhanced computed tomography (CT) for local staging remains incompletely assessed. Aims of the study were to evaluate CT accuracy in discriminating active from aggressive tumours compared to histology and evaluate the role of CT angiography (CTA) in surgical planning. This retrospective cohort series of 88 cases from 1200 patients (7 %) was locally studied by contrast-enhanced CT and CTA in a referral centre: 74 malignant tumours, 14 benign lesions. Contrast-enhancement patterns and relationship of the mass with major vessels and bone were compared with histology on surgically excised samples. Sensitivity, specificity, positive and negative predictive values (PPV, NPV) were evaluated in discriminating active from aggressive tumours. Sensitivity in differentiating aggressive tumours from active lesions was 89 %, specificity 84 %, PPV 90 %, NPV 82 %. The relationship between mass and major vessels/bone was fundamental for surgical strategy respectively in 40 % and in 58 % of malignant tumours. Contrast-enhanced CT and CTA are effective in differentiating aggressive masses from active lesions in soft tissue and in depicting the relationship between tumour and adjacent bones and major vessels. (orig.)

  14. Inductive testing of reactor pressure vessels

    International Nuclear Information System (INIS)

    Bergh, H.

    1987-01-01

    In Service Inspection of Reactor Pressure Vessels is mostly done with ultrasonics. Using special 2 crystal-probes good detectability is achieved for near surface defects. The problem is to detect closely spaced cracks, to decide if the defects are surface braking and, if not, to decide the remaining ligament. The purpose of this study is to investigate to what extent Eddy Current can solve these problems. Detecting surfacebreaking cracks and fields of cracks can be done using conventional Eddy Current techniques. Mapping of closely spaced cracks requires a small probe and a high frequency. Measurement of depths a larger probe, a lower frequency and knowledge of the crackfield since 2 closely spaced shallow cracks might be mistaken for one deep crack. Depths of singel cracks can be measured down to 7-8 mm. In closely spaced crackfields the depths can not be measured. The measurement is mostly based on amplitude. For not surface breaking defects the problem is to decide the ligament, i.e. the distance between surface and cracktip. To achieve good penetration a large probe, low frequency and high energy or pulsed energy is used. Ligament up to 4 mm can be measured with good accuracy. The measurements is mostly based on phase. Noise, which originates from rough surface, varied material structure and lift off, can be reduced using multi frequency mix, probe design and scanning pattern. (author)

  15. Nuclear reactor installation with outer shell enclosing a primary pressure vessel

    International Nuclear Information System (INIS)

    1975-01-01

    The high temperature nuclear reactor installation described includes a fluid cooled nuclear heat source, a primary pressure vessel containing the heat source, an outer shell enclosing the primary pressure vessel and acting as a secondary means of containment for this vessel against outside projectiles. Multiple auxiliary equipment points are arranged outside the outer shell which comprises a part of a lower wall around the primary pressure vessel, an annular part integrated in the lower wall and extending outwards as from this wall and an upper part integrated in the annular part and extending above this annular part and above the primary pressure vessel. The annular part and the primary pressure vessel are formed with vertical penetrations which can be closed communicating respectively with the auxiliary equipment points and with inside the pressure vessel whilst handling gear is provided in the upper part for vertically raising reactor components through these penetrations and for transporting them over the annular part and over the primary pressure vessel [fr

  16. An automated and robust image processing algorithm for glaucoma diagnosis from fundus images using novel blood vessel tracking and bend point detection.

    Science.gov (United States)

    M, Soorya; Issac, Ashish; Dutta, Malay Kishore

    2018-02-01

    Glaucoma is an ocular disease which can cause irreversible blindness. The disease is currently identified using specialized equipment operated by optometrists manually. The proposed work aims to provide an efficient imaging solution which can help in automating the process of Glaucoma diagnosis using computer vision techniques from digital fundus images. The proposed method segments the optic disc using a geometrical feature based strategic framework which improves the detection accuracy and makes the algorithm invariant to illumination and noise. Corner thresholding and point contour joining based novel methods are proposed to construct smooth contours of Optic Disc. Based on a clinical approach as used by ophthalmologist, the proposed algorithm tracks blood vessels inside the disc region and identifies the points at which first vessel bend from the optic disc boundary and connects them to obtain the contours of Optic Cup. The proposed method has been compared with the ground truth marked by the medical experts and the similarity parameters, used to determine the performance of the proposed method, have yield a high similarity of segmentation. The proposed method has achieved a macro-averaged f-score of 0.9485 and accuracy of 97.01% in correctly classifying fundus images. The proposed method is clinically significant and can be used for Glaucoma screening over a large population which will work in a real time. Copyright © 2017 Elsevier B.V. All rights reserved.

  17. Recovery of testicular blood flow following ligation of testicular vessels

    International Nuclear Information System (INIS)

    Pascual, J.A.; Villanueva-Meyer, J.; Salido, E.; Ehrlich, R.M.; Mena, I.; Rajfer, J.

    1989-01-01

    To determine whether initial ligation of the testicular vessels of the high undescended testis followed by a delayed secondary orchiopexy is a viable alternative to the classical Fowler-Stephens procedure, a series of preliminary experiments were conducted in the rat in which testicular blood flow was measured by the 133-xenon washout technique before, and 1 hour and 30 days after ligation of the vessels. In addition, testicular histology, and testis and sex-accessory tissue weights were measured in 6 control, 6 sham operated and 6 testicular vessel ligated rats 54 days after vessel ligation. The data demonstrate that ligation and division of the testicular blood vessels produce an 80 per cent decrease in testicular blood flow 1 hour after ligation of the vessels. However, 30 days later testis blood flow returns to the control and pre-treatment value. There were no significant changes in testis or sex-accessory tissue weights 54 days after vessel ligation. Histologically, 4 of the surgically operated testes demonstrated necrosis of less than 25 per cent of the seminiferous tubules while 1 testis demonstrated more than 75 per cent necrosis. The rest of the tubules in all 6 testes demonstrated normal spermatogenesis. From this study we conclude that initial testicular vessel ligation produces an immediate decrease in testicular blood flow but with time the collateral vessels are able to compensate and return the testis blood flow to its normal pre-treatment value. These preliminary observations lend support for the concept that initial ligation of the testicular vessels followed by a delayed secondary orchiopexy in patients with a high undescended testis may be a possible alternative to the classical Fowler-Stephens approach

  18. Dynamic stroma reorganization drives blood vessel dysmorphia during glioma growth.

    Science.gov (United States)

    Mathivet, Thomas; Bouleti, Claire; Van Woensel, Matthias; Stanchi, Fabio; Verschuere, Tina; Phng, Li-Kun; Dejaegher, Joost; Balcer, Marly; Matsumoto, Ken; Georgieva, Petya B; Belmans, Jochen; Sciot, Raf; Stockmann, Christian; Mazzone, Massimiliano; De Vleeschouwer, Steven; Gerhardt, Holger

    2017-12-01

    Glioma growth and progression are characterized by abundant development of blood vessels that are highly aberrant and poorly functional, with detrimental consequences for drug delivery efficacy. The mechanisms driving this vessel dysmorphia during tumor progression are poorly understood. Using longitudinal intravital imaging in a mouse glioma model, we identify that dynamic sprouting and functional morphogenesis of a highly branched vessel network characterize the initial tumor growth, dramatically changing to vessel expansion, leakage, and loss of branching complexity in the later stages. This vascular phenotype transition was accompanied by recruitment of predominantly pro-inflammatory M1-like macrophages in the early stages, followed by in situ repolarization to M2-like macrophages, which produced VEGF-A and relocate to perivascular areas. A similar enrichment and perivascular accumulation of M2 versus M1 macrophages correlated with vessel dilation and malignancy in human glioma samples of different WHO malignancy grade. Targeting macrophages using anti-CSF1 treatment restored normal blood vessel patterning and function. Combination treatment with chemotherapy showed survival benefit, suggesting that targeting macrophages as the key driver of blood vessel dysmorphia in glioma progression presents opportunities to improve efficacy of chemotherapeutic agents. We propose that vessel dysfunction is not simply a general feature of tumor vessel formation, but rather an emergent property resulting from a dynamic and functional reorganization of the tumor stroma and its angiogenic influences. © 2017 The Authors. Published under the terms of the CC BY 4.0 license.

  19. Vessel Sewage Discharges: Statutes, Regulations, and Related Laws and Treaties

    Science.gov (United States)

    Vessel sewage discharges can be regulated under multiple statutes, regulations, and laws/treaties, including the Clean Water Act, Title XIV, MARPOL Annex IV and the Vessel General Permit. This page describes how these are applied to vessel sewage.

  20. Diagnostic accuracy of dual-source CT coronary angiography in a population unselected for degree of coronary artery calcification and without heart rate modification

    International Nuclear Information System (INIS)

    Lin, C.-J.; Hsu, J.-C.; Lai, Y.-J.; Wang, K.-L.; Lee, J.-Y.; Li, A.-H.; Chu, S.-H.

    2010-01-01

    Aim: To assess the ability of coronary angiography performed using dual-source computed tomography (DSCT) to evaluate coronary artery disease (CAD) in a population with unselected heart rates and extensive coronary calcification. Materials and methods: Forty-four patients at intermediate to high risk for CAD underwent both DSCT coronary angiography and invasive coronary angiography (ICA) within 30 days. No beta blockers were administered prior to imaging. Image quality and quantitatively stenosis of all coronary segments with a diameter ≥1.5 mm were accessed. Patients were stratified according to mean heart rate (<70 versus ≥70 bpm) and heart rate variability (<10 versus ≥10 bpm). DSCT detection of coronary stenosis by segment, vessel, and patient characteristics were compared to the reference standard of ICA. Results: Diagnostic accuracy for all patients was high regarding sensitivity (97%), positive predictive value (PPV, 84.2%), and negative predictive value (NPV, 83.3%) but low regarding specificity (45.5%) with a moderate interobserver agreement (Kappa = 0.50). The accuracy for vessel-based diagnosis was high regarding sensitivity (96.6%), specificity (80.8%), PPV (80.3%), and NPV (96.7%). The segment-based diagnostic results revealed a moderate interobserver agreement for image quality and sensitivity, specificity, PPV and NPV for all segments of 66.9, 97.8, 90.8, and 89.9%, respectively. Conclusion: DSCT coronary angiography has high diagnostic accuracy in assessing CAD among patients at intermediate to high risk without using heart rate-modulating premedication. DSCT is not superior to ICA for diagnosis of calcified segments.