WorldWideScience

Sample records for greater commercial availability

  1. Higher Storage Temperature Causes Greater Salmonella enterica Serovar Typhimurium Internal Penetration of Artificially Contaminated, Commercially Available, Washed Free Range Eggs.

    Science.gov (United States)

    Whiley, Alice; Fallowfield, Howard; Ross, Kirstin; McEvoy, Vanessa; Whiley, Harriet

    2016-07-01

    Foodborne salmonellosis is a major public health concern, with contaminated eggs identified as a significant source of infection. In Australia, the most prevalent cause of salmonellosis from eggs is Salmonella enterica subsp. enterica serovar Typhimurium. This study explored the effect of temperature after 1, 7, 14, 21, and 28 days of storage on commercially available washed free range eggs, artificially contaminated with Salmonella Typhimurium on the external surface. At each time point, the external surface of the egg, the crushed eggshell, and the internal egg yolk and albumen were analyzed for Salmonella. After 28 days of storage, 25% of eggs stored at 4°C, 50% of eggs stored at 14°C, and 100% of eggs stored at 23 and 35°C were internally contaminated with Salmonella. After 1 day of storage, more than 50% of all eggs had Salmonella present in the crushed shell after the external surface had been disinfected with ethanol. This is the first study to demonstrate that refrigeration reduced the potential for Salmonella Typhimurium to penetrate the eggshell membrane and internally contaminate table eggs commercially available in Australia. It also suggests that the processes of cracking eggs may be a source of cross-contamination within the kitchen.

  2. EVALUATING COMMERCIALLY AVAILABLE DERMAL ...

    Science.gov (United States)

    As the Human Exposure Program focuses on the exposure of children to pesticides, there are concerns about the effect, or perceived effect, of components of the sampling procedure on the health and well-being of the infant and the ability to collect pesticide residues. One concern involves the materials in wipes used to collect pesticide residues or other contact materials on the skin. In recent studies (e.g., National Human Exposure Assessment Survey; NHEXAS), isopropyl alcohol has been used as a solvent in conjunction with a cloth wipe to obtain samples from the hands of adults and children. Although isopropyl alcohol is generally considered innocuous, the use of commercially available products could eliminate concerns about exposure to alcohol. A few studies have evaluated the potential of commercially available baby wipes to collect personal exposure samples for metals research, but not for the area of pesticide research (Millson et al., 1994; Campbell et al., 1993; Lichtenwalner et al., 1993). Therefore, there is a need to evaluate the potential for using commercially available baby wipes for collecting pesticide samples from skin and other surfaces. Another concern involves establishing a convenient and safe method for assessing overall dermal exposure for children, especially for those in crawling stage. One route that the U .S. Environmental Protection Agency (EPA) would like to investigate is the use of cotton body suits (infant sleepers) as an indicator

  3. Commercially available video motion detectors

    International Nuclear Information System (INIS)

    1979-01-01

    A market survey of commercially available video motion detection systems was conducted by the Intrusion Detection Systems Technology Division of Sandia Laboratories. The information obtained from this survey is summarized in this report. The cutoff date for this information is May 1978. A list of commercially available video motion detection systems is appended

  4. Guide to commercially available wind machines

    Energy Technology Data Exchange (ETDEWEB)

    1978-04-03

    Wind Energy Conversion Systems (WECS) commercially available in the United States are described. The terms used to describe these wind systems are defined and their significance discussed. Lists of manufacturers and distributors, subsystem components and suppliers, and references are provided.

  5. How valid are commercially available medical simulators?

    NARCIS (Netherlands)

    Stunt, J.J.; Wulms, P.H.; Kerkhoffs, G.M.; Dankelman, J.; Van Dijk, C.N.; Tuijthof, G.J.M.

    2014-01-01

    Background: Since simulators offer important advantages, they are increasingly used in medical education and medical skills training that require physical actions. A wide variety of simulators have become commercially available. It is of high importance that evidence is provided that training on

  6. BERYLLIUM MEASUREMENT IN COMMERCIALLY AVAILABLE WET WIPES

    Energy Technology Data Exchange (ETDEWEB)

    Youmans-Mcdonald, L.

    2011-02-18

    Analysis for beryllium by fluorescence is now an established method which is used in many government-run laboratories and commercial facilities. This study investigates the use of this technique using commercially available wet wipes. The fluorescence method is widely documented and has been approved as a standard test method by ASTM International and the National Institute for Occupational Safety and Health (NIOSH). The procedure involves dissolution of samples in aqueous ammonium bifluoride solution and then adding a small aliquot to a basic hydroxybenzoquinoline sulfonate fluorescent dye (Berylliant{trademark} Inc. Detection Solution Part No. CH-2) , and measuring the fluorescence. This method is specific to beryllium. This work explores the use of three different commercial wipes spiked with beryllium, as beryllium acetate or as beryllium oxide and subsequent analysis by optical fluorescence. The effect of possible interfering metals such as Fe, Ti and Pu in the wipe medium is also examined.

  7. Beryllium Measurement In Commercially Available Wet Wipes

    International Nuclear Information System (INIS)

    Youmans-Mcdonald, L.

    2011-01-01

    Analysis for beryllium by fluorescence is now an established method which is used in many government-run laboratories and commercial facilities. This study investigates the use of this technique using commercially available wet wipes. The fluorescence method is widely documented and has been approved as a standard test method by ASTM International and the National Institute for Occupational Safety and Health (NIOSH). The procedure involves dissolution of samples in aqueous ammonium bifluoride solution and then adding a small aliquot to a basic hydroxybenzoquinoline sulfonate fluorescent dye (Berylliant(trademark) Inc. Detection Solution Part No. CH-2) , and measuring the fluorescence. This method is specific to beryllium. This work explores the use of three different commercial wipes spiked with beryllium, as beryllium acetate or as beryllium oxide and subsequent analysis by optical fluorescence. The effect of possible interfering metals such as Fe, Ti and Pu in the wipe medium is also examined.

  8. How valid are commercially available medical simulators?

    Science.gov (United States)

    Stunt, JJ; Wulms, PH; Kerkhoffs, GM; Dankelman, J; van Dijk, CN; Tuijthof, GJM

    2014-01-01

    Background Since simulators offer important advantages, they are increasingly used in medical education and medical skills training that require physical actions. A wide variety of simulators have become commercially available. It is of high importance that evidence is provided that training on these simulators can actually improve clinical performance on live patients. Therefore, the aim of this review is to determine the availability of different types of simulators and the evidence of their validation, to offer insight regarding which simulators are suitable to use in the clinical setting as a training modality. Summary Four hundred and thirty-three commercially available simulators were found, from which 405 (94%) were physical models. One hundred and thirty validation studies evaluated 35 (8%) commercially available medical simulators for levels of validity ranging from face to predictive validity. Solely simulators that are used for surgical skills training were validated for the highest validity level (predictive validity). Twenty-four (37%) simulators that give objective feedback had been validated. Studies that tested more powerful levels of validity (concurrent and predictive validity) were methodologically stronger than studies that tested more elementary levels of validity (face, content, and construct validity). Conclusion Ninety-three point five percent of the commercially available simulators are not known to be tested for validity. Although the importance of (a high level of) validation depends on the difficulty level of skills training and possible consequences when skills are insufficient, it is advisable for medical professionals, trainees, medical educators, and companies who manufacture medical simulators to critically judge the available medical simulators for proper validation. This way adequate, safe, and affordable medical psychomotor skills training can be achieved. PMID:25342926

  9. How valid are commercially available medical simulators?

    Directory of Open Access Journals (Sweden)

    Stunt JJ

    2014-10-01

    Full Text Available JJ Stunt,1 PH Wulms,2 GM Kerkhoffs,1 J Dankelman,2 CN van Dijk,1 GJM Tuijthof1,2 1Orthopedic Research Center Amsterdam, Department of Orthopedic Surgery, Academic Medical Centre, Amsterdam, the Netherlands; 2Department of Biomechanical Engineering, Faculty of Mechanical, Materials and Maritime Engineering, Delft University of Technology, Delft, the Netherlands Background: Since simulators offer important advantages, they are increasingly used in medical education and medical skills training that require physical actions. A wide variety of simulators have become commercially available. It is of high importance that evidence is provided that training on these simulators can actually improve clinical performance on live patients. Therefore, the aim of this review is to determine the availability of different types of simulators and the evidence of their validation, to offer insight regarding which simulators are suitable to use in the clinical setting as a training modality. Summary: Four hundred and thirty-three commercially available simulators were found, from which 405 (94% were physical models. One hundred and thirty validation studies evaluated 35 (8% commercially available medical simulators for levels of validity ranging from face to predictive validity. Solely simulators that are used for surgical skills training were validated for the highest validity level (predictive validity. Twenty-four (37% simulators that give objective feedback had been validated. Studies that tested more powerful levels of validity (concurrent and predictive validity were methodologically stronger than studies that tested more elementary levels of validity (face, content, and construct validity. Conclusion: Ninety-three point five percent of the commercially available simulators are not known to be tested for validity. Although the importance of (a high level of validation depends on the difficulty level of skills training and possible consequences when skills are

  10. Evaluation of commercially available decontamination chemicals

    International Nuclear Information System (INIS)

    Shurte, E.A.; Rankin, W.N.

    1988-01-01

    The effectiveness of commercially available decontamination solutions was compared with the effectiveness of 10% oxalic acid in controlled laboratory tests. Type 304L stainless steel and Inconel 625 specimens were used. Contamination was sludge from Savannah River Plant (SRP) high level waste tanks. Measured amounts of contamination were placed on each specimen. They were then heated to bond the contamination to the surface and cleaned according to the manufacturer's directions. The effectiveness of the product was determined by monitoring specimens before and after cleaning. Four of the 16 solutions evaluated removed all the contamination from Type 304L stainless steel. Inconel 625 was more difficult to decontaminate. Further tests are planned with the chemicals that were most effective in this test. 4 refs., 6 tabs

  11. Evaluation of commercially available decontamination chemicals

    International Nuclear Information System (INIS)

    Shurte, E.A.

    1988-01-01

    The effectiveness of commercially available decontamination solutions was compared with the effectiveness of 10% oxalic acid in controlled lab. tests. Type 304L stainless steel and Inconel 625 specimens were used. Contamination was sludge from Savannah River Plant (SRP) high level waste tanks. Measured amounts of contamination were placed on each specimen. They were then heated to bond the contamination to the surface and cleaned according to the manufacturer's directions. The effectiveness of the produce was determined by monitoring specimens before and after cleaning. Four of the 16 solutions evaluated removed all the contamination from Type 304L stainless steel. Inconel 625 was more difficult to decontaminate. Further tests are planned with the chemicals that were most effective in this test

  12. Shaping-lathe headrig now commercially available

    Science.gov (United States)

    P. Koch

    1975-01-01

    On September 12, 1975, twenty-five sawmillers from throughout North America watched as a new headrig produced cants of various shapes and a usable residue of flakes from logs of irregular contour. The demonstration at the Stetson-Ross plant in Seattle, Washington, was the unveiling of the commercial model of a design introduced by the Southern Forest Experiment Station...

  13. Commercially available molecular tests for human papillomaviruses (HPV): 2015 update.

    Science.gov (United States)

    Poljak, Mario; Kocjan, Boštjan J; Oštrbenk, Anja; Seme, Katja

    2016-03-01

    Commercial molecular tests for human papillomaviruses (HPV) are invaluable diagnostic tools in cervical carcinoma screening and management of women with cervical precancerous lesions as well as important research tools for epidemiological studies, vaccine development, and implementation and monitoring of vaccination programs. In this third inventory of commercial HPV tests, we identified 193 distinct commercial HPV tests and at least 127 test variants available on the market in 2015, which represents a 54% and 79% increase in the number of distinct HPV tests and variants, respectively, in comparison to our last inventory performed in 2012. Identified HPV tests were provisionally divided into eight main groups and several subgroups. Among the 193 commercial HPV tests, all but two target alpha-HPV types only. Although the number of commercial HPV tests with at least one published study in peer-reviewed literature has increased significantly in the last three years, several published performance evaluations are still not in line with agreed-upon standards in the HPV community. Manufacturers should invest greater effort into evaluating their products and publishing validation/evaluation results in peer-reviewed journals. To achieve this, more clinically oriented external quality-control panels and initiatives are required. For evaluating the analytical performance of the entire range of HPV tests currently on the market, more diverse and reliable external quality-control programs based on international standards for all important HPV types are indispensable. The performance of a wider range of HPV tests must be promptly evaluated on a variety of alternative clinical specimens. In addition, more complete HPV assays containing validated sample-extraction protocols and appropriate internal controls are urgently needed. Provision of a broader range of automated systems allowing large-scale HPV testing as well as the development of reliable, rapid, and affordable molecular

  14. Thyroxine and triiodothyronine content in commercially available thyroid health supplements.

    Science.gov (United States)

    Kang, Grace Y; Parks, Jonathan R; Fileta, Bader; Chang, Audrey; Abdel-Rahim, Maged M; Burch, Henry B; Bernet, Victor J

    2013-10-01

    As defined by the Dietary Supplement Health and Education Act 1997, such substances as herbs and dietary supplements fall under general Food and Drug Administration supervision but have not been closely regulated to date. We examined the thyroid hormone content in readily available dietary health supplements marketed for "thyroid support." Ten commercially available thyroid dietary supplements were purchased. Thyroid supplements were dissolved in 10 mL of acetonitrile and water with 0.1% trifloroacetic acid and analyzed using high-performance liquid chromatography for the presence of both thyroxine (T4) and triiodothyronine (T3) using levothyroxine and liothyronine as a positive controls and standards. The amount of T4 and T3 was measured separately for each supplement sample. Nine out of 10 supplements revealed a detectable amount of T3 (1.3-25.4 μg/tablet) and 5 of 10 contained T4 (5.77-22.9 μg/tablet). Taken at the recommended dose, 5 supplements delivered T3 quantities of greater than 10 μg/day, and 4 delivered T4 quantities ranging from 8.57 to 91.6 μg/day. The majority of dietary thyroid supplements studied contained clinically relevant amounts of T4 and T3, some of which exceeded common treatment doses for hypothyroidism. These amounts of thyroid hormone, found in easily accessible dietary supplements, potentially expose patients to the risk of alterations in thyroid levels even to the point of developing iatrogenic thyrotoxicosis. The current study results emphasize the importance of patient and provider education regarding the use of dietary supplements and highlight the need for greater regulation of these products, which hold potential danger to public health.

  15. Antibacterial efficacy of raw and commercially available honey

    African Journals Online (AJOL)

    Administrator

    2011-09-19

    Sep 19, 2011 ... Key words: Honey, antibacterial activity, raw honey, commercially available honey, minimum inhibitory ... against pathogenic bacteria, oral bacteria as well as food .... explore the possible benefits of the use of honey among.

  16. Transport behaviour of commercially available 100-Omega standard resistors

    CSIR Research Space (South Africa)

    Schumacher, B

    2001-04-01

    Full Text Available Several types of commercial 100-Omega resistors can be used with the cryogenic current comparator to maintain the resistance unit, derived from the Quantized Hall Effect (QHE), and to disseminate this unit to laboratory resistance standards. Up...

  17. Problems in radioimmunoassay of human lutropin with commercially available regents

    International Nuclear Information System (INIS)

    Hammond, J.E.; Phillips, J.C.; Straight, C.B.; Hammond, M.G.

    1980-01-01

    To evaluate five commercially available reagent sets supplied for the radioimmunoassay of lutropin, we determined whether there was parallelism between the curve given by dilutions of the standards supplied by the manufacturers, by dilutions of a serum pool, and by dilutions of a standard preparation from human pituitaries, LER-907. These studies demonstrated significant analytical problems with three of the five sets. We conclude that each user should carefully evaluate all commercially available radioimmunoassays for lutropin (and, by inference, for other peptide hormones) before use

  18. Hepatic differentiation potential of commercially available human mesenchymal stem cells.

    Science.gov (United States)

    Ong, Shin-Yeu; Dai, Hui; Leong, Kam W

    2006-12-01

    The ready availability and low immunogenicity of commercially available mesenchymal stem cells (MSC) render them a potential cell source for the development of therapeutic products. With cell source a major bottleneck in hepatic tissue engineering, we investigated whether commercially available human MSC (hMSC) can transdifferentiate into the hepatic lineage. Based on previous studies that find rapid gain of hepatic genes in bone marrow-derived stem cells cocultured with liver tissue, we used a similar approach to drive hepatic differentiation by coculturing the hMSC with rat livers treated or untreated with gadolinium chloride (GdCl(3)). After a 24-hour coculture period with liver tissue injured by GdCl(3) in a Transwell configuration, approximately 34% of the cells differentiated into albumin-expressing cells. Cocultured cells were subsequently maintained with growth factors to complete the hepatic differentiation. Cocultured cells expressed more hepatic gene markers, and had higher metabolic functions and P450 activity than cells that were only differentiated with growth factors. In conclusion, commercially available hMSC do show hepatic differentiation potential, and a liver microenvironment in culture can provide potent cues to accelerate and deepen the differentiation. The ability to generate hepatocyte-like cells from a commercially available cell source would find interesting applications in liver tissue engineering.

  19. Mechanical Behavior of Fully Expanded Commercially Available Endovascular Coronary Stents

    OpenAIRE

    Tambaca, Josip; Canic, Suncica; Kosor, Mate; Fish, R. David; Paniagua, David

    2011-01-01

    The mechanical behavior of endovascular coronary stents influences their therapeutic efficacy. Through computational studies, researchers can analyze device performance and improve designs. We developed a 1-dimensional finite element method, net-based algorithm and used it to analyze the effects of radial loading and bending in commercially available stents. Our computational study included designs modeled on the Express, Cypher, Xience, and Palmaz stents.

  20. Evaluation of Taste Properties of Commercially Available Salts

    OpenAIRE

    ISHIKAWA, Kyoko; SUGIMOTO, Maho; KUMAGAI, Masanori; MATSUNAGA, Ryuji

    2006-01-01

    This study examined commercially available salts'taste properties. The salts were used in preparation of four dishes: asazuke of cucumber, asazuke of Chinese cabbage, clear soup, and green soybean rice. The respective tastes of the salts in those prepared foods differed from those of the salts alone. We evaluated the parameters: saltiness, mildness, unpleasantness, and palatability. Differences of the salt samples affected the perception of saltiness. Results of taste sensor analyses showed t...

  1. Comparative evaluation of some commercially available brands of rifampacin tablets

    International Nuclear Information System (INIS)

    Shah, S.N.; Mahmood, K.; Uzair, M.; Rabbani, M.

    2009-01-01

    The objective of this study was to evaluate some commercially available brands of Rifampacin Tablets. In in- vitro release studies of physical parameters of tablet i.e. disintegration, dissolution rate, crushing strength, thickness and diameter, uniformity of weight and assay of the active ingredients of four brands of commercially available Rifampacin tablet i.e. A, B, C and D were performed. For this purpose, Dissolution rate was studied in phosphate buffer at pH 6.0, 6.5 and 7.4 using USP rotating basket at 100 rpm. The data was analyzed by Cube-Root law and calculated dissolution rate constant predicting in vitro behavior of the drug released from these preparations. In this particular case two types of dissolution mechanisms were founded; in first 20 minutes, the fast release phase and after 20 minutes the slow release phase. According to the degree of dissolution of D and B proved to be the best of the available commercial brands. (author)

  2. Comparison of efficacy of three commercially available antibiotic discs

    Directory of Open Access Journals (Sweden)

    Joshi A

    2008-01-01

    Full Text Available A study was undertaken to evaluate the efficacy of commercially available antimicrobial discs manufactured by Oxoid, UK, HiMedia Laboratories, Mumbai and Span Diagnostics, Surat. The discs were evaluated for their performance on the basis of percentage of coefficient of variation (%CV which is a measure of reproducibility, mean zone diameters which is a measure of accuracy and range of zone diameter using both standard ATCC strains and clinical isolates. The data showed variation for all three manufacturers and therefore routine and regular quality control of discs as well as meticulous following of good laboratory practices is strongly advocated in clinical laboratories

  3. Characteristics of commercially available well scintillation counting systems

    International Nuclear Information System (INIS)

    Morris, A.C. Jr.; Dudley, R.A.

    1977-01-01

    The document contains data on commercially available well scintillation counting systems as collected during early 1977, and up-dated in July 1977, by the staff of the Medical Application Section, Division of Life Sciences, IAEA. These data also appear as Appendix 2 of IAEA-201, Well Scintillation Counting Systems for Nuclear Medicine Applications in Developing Countries, Vienna, 1977. An attempt was made to include instruments currently offered by all manufacturers. However, it is inevitable that several manufacturers remain unknown to the Section, and a number of known manufacturers failed to provide adequate information. (orig.) [de

  4. Natural radiation source fabricated from commercially available instant coffee

    International Nuclear Information System (INIS)

    Kawano, Takao; Ando, Yoshiaki; Izumi, Yuuichi

    2015-01-01

    Commercially available instant coffee, Nescafe Excella, contained the radionuclide 40 K. From the instant coffee, sixteen coffee-block radiation sources were successfully fabricated with sufficiently low production dependences. The coffee-block radiation sources were examined their suitability for a radiation protection course. Although a part of radiation counts(cpm) obtained with 1 minute measurement were largely deviated, those determined by 5 minute measurements and five times of 1 minute measurement were less deviated, enabling better comprehension of the three cardinal principles of radiation protection. (author)

  5. Ma2 antibodies: an evaluation of commercially available detection methods.

    Science.gov (United States)

    Johannis, Wibke; Renno, Joerg H; Wielckens, Klaus; Voltz, Raymond

    2011-01-01

    Ma2 antibodies belong to the onconeuronal antibodies which define a "definite" paraneoplastic neurological syndrome (PNS). Because of the clinical relevance, use of two separate methods (indirect immunofluorescence technique--IFT--and immunoblot) is advocated; however, with an increasing number of commercially available assay systems, usually only one assay is performed. We compared IFT and three commercially available immunoblots (ravo Diagnostika, Euroimmun, Milenia Biotec) on sera from 35 patients with clinically suspected PNS. 17 were Ma2 antibody associated as defined by consensus result (showing positive reactivity in 2 assays), 18 were Ma2 antibody negative controls. Sensitivity/specificity for single assays were for IFT 94%/94%, for ravo Diagnostika PNS blot 88%/100%, for Euroimmun Neuronal Antigens Profile blot 100%/89%, and for Milenia Biotec MTR blot 94%/100%. Our data confirm, although all tests performed well, a combination of 2 independent assays is still advisable for Ma2 antibody detection in order to achieve higher sensitivity and specificity rates.

  6. Fatty acid composition of commercially available Iranian edible oils

    Directory of Open Access Journals (Sweden)

    Sedigheh Asgary

    2009-08-01

    Full Text Available

    • BACKGROUND: Trans-fatty acids (TFAs, unsaturated fats with at least one double bond in the Trans configuration, are industrially formed in large quantities when vegetable oils are partially hydrogenated. This study was  ndertaken to quantify the amounts of the common fatty acids in several commercial oils marketing in Iran.
    • METHODS: The most consumed commercially available brands of vegetable oils were randomly selected from products available in supermarkets. A 10g sample was drawn from each mixed sample and prepared for fatty cid analysis by gas chromatography (GC.
    • RESULTS: Palmitic acid (C16:0 and stearic acid (C18:0 jointly constituted 21% of total fatty acids in partially hydrogenated vegetable oils (PHVOs. More than one third of total fatty acids in Iranian PHVOs were Trans fats. TFAs constituted almost 1% and 3% of total fatty  cids in Iranian cooking and frying oils. This study  howed higher contents of TFAs in Iranian commercially available hydrogenated vegetable oils. Statistical Package for Social Sciences was used for all statistical analyses.
    • CONCLUSIONS: Although

    • Noise data management using commercially available data-base software

      International Nuclear Information System (INIS)

      Damiano, B.; Thie, J.A.

      1988-01-01

      A data base has been created using commercially available software to manage the data collected by an automated noise data acquisition system operated by Oak Ridge National Laboratory at the Fast Flux Test Facility (FFTF). The data base was created to store, organize, and retrieve selected features of the nuclear and process signal noise data, because the large volume of data collected by the automated system makes manual data handling and interpretation based on visual examination of noise signatures impractical. Compared with manual data handling, use of the data base allows the automatically collected data to be utilized more fully and effectively. The FFTF noise data base uses the Oracle Relational Data Base Management System implemented on a desktop personal computer

    • Evaluation of DSA test phantoms commercially available in the UK

      International Nuclear Information System (INIS)

      Cowen, A.R.; Coleman, N.J.; HArtley, P.J.

      1985-01-01

      Several digital subtraction angiography systems have been installed in the United Kingdom. Many others will no doubt be installed over the next few years. Given the high cost and technical complexity of DSA systems it is natural that the purchasers of such equipment should be concerned that their machine has been adjusted correctly prior to clinical acceptance and continues to operate satisfactorily thereafter. In response to these concerns several companies in the U.K. are now selling DSA test phantoms. All DSA phantoms which are currently commercially available are manufactured in the U.S.A. Im order to assess the effectiveness of these phantoms the DHSS has initiated the assessment project described here. The findings are tabulated . Performance is indicated by a star rating system, based on the opinions of two X-ray engineers and one medical physicist. (author)

    • Structure-Based Virtual Screening of Commercially Available Compound Libraries.

      Science.gov (United States)

      Kireev, Dmitri

      2016-01-01

      Virtual screening (VS) is an efficient hit-finding tool. Its distinctive strength is that it allows one to screen compound libraries that are not available in the lab. Moreover, structure-based (SB) VS also enables an understanding of how the hit compounds bind the protein target, thus laying ground work for the rational hit-to-lead progression. SBVS requires a very limited experimental effort and is particularly well suited for academic labs and small biotech companies that, unlike pharmaceutical companies, do not have physical access to quality small-molecule libraries. Here, we describe SBVS of commercial compound libraries for Mer kinase inhibitors. The screening protocol relies on the docking algorithm Glide complemented by a post-docking filter based on structural protein-ligand interaction fingerprints (SPLIF).

    • Noise Measurement and Frequency Analysis of Commercially Available Noisy Toys

      Directory of Open Access Journals (Sweden)

      Shohreh Jalaie

      2005-06-01

      Full Text Available Objective: Noise measurement and frequency analysis of commercially available noisy toys were the main purposes of the study. Materials and Methods: 181 noisy toys commonly found in toy stores in different zones of Tehran were selected and categorized into 10 groups. Noise measurement were done at 2, 25, and 50 cm from toys in dBA. The noisiest toy of each group was frequency analyzed in octave bands. Results: The highest and the lowest intensity levels belonged to the gun (mean=112 dBA and range of 100-127 dBA and to the rattle-box (mean=84 dBA and range of 74-95 dBA, respectively. Noise intensity levels significantly decreased with increasing distance except for two toys. Noise frequency analysis indicated energy in effective hearing frequencies. Most of the toys energies were in the middle and high frequency region. Conclusion: As intensity level of the toys is considerable, mostly more than 90 dBA, and also their energy exist in the middle and high frequency region, toys should be considered as a cause of the hearing impairment.

    • Improving web site performance using commercially available analytical tools.

      Science.gov (United States)

      Ogle, James A

      2010-10-01

      It is easy to accurately measure web site usage and to quantify key parameters such as page views, site visits, and more complex variables using commercially available tools that analyze web site log files and search engine use. This information can be used strategically to guide the design or redesign of a web site (templates, look-and-feel, and navigation infrastructure) to improve overall usability. The data can also be used tactically to assess the popularity and use of new pages and modules that are added and to rectify problems that surface. This paper describes software tools used to: (1) inventory search terms that lead to available content; (2) propose synonyms for commonly used search terms; (3) evaluate the effectiveness of calls to action; (4) conduct path analyses to targeted content. The American Academy of Orthopaedic Surgeons (AAOS) uses SurfRay's Behavior Tracking software (Santa Clara CA, USA, and Copenhagen, Denmark) to capture and archive the search terms that have been entered into the site's Google Mini search engine. The AAOS also uses Unica's NetInsight program to analyze its web site log files. These tools provide the AAOS with information that quantifies how well its web sites are operating and insights for making improvements to them. Although it is easy to quantify many aspects of an association's web presence, it also takes human involvement to analyze the results and then recommend changes. Without a dedicated resource to do this, the work often is accomplished only sporadically and on an ad hoc basis.

    • Acid and Volatiles of Commercially-Available Lambic Beers

      Directory of Open Access Journals (Sweden)

      Katherine Thompson Witrick

      2017-10-01

      Full Text Available Lambic beer is the oldest style of beer still being produced in the Western world using spontaneous fermentation. Gueuze is a style of lambic beer prepared by mixing young (one year and older (two to three years beers. Little is known about the volatiles and semi-volatiles found in commercial samples of gueuze lambic beers. SPME was used to extract the volatiles from nine different brands of lambic beer. GC-MS was used for the separation and identification of the compounds extracted with SPME. The pH and color were measured using standard procedures. A total of 50 compounds were identified in the nine brands. Seventeen of the 50 compounds identified have been previously identified. The compounds identified included a number of different chemical groups such as acids, alcohols, phenols, ketones, aldehydes, and esters. Ethyl acetate, 4-ethylphenol, and 4-ethylguaiacol are known by-products of the yeast, Brettanomyces, which is normally a spoilage microorganism in beer and wine, but important for the flavor characteristics of lambic beer. There were no differences in pH, but there were differences in color between the beer samples.

    • Commercially available interactive video games in burn rehabilitation: therapeutic potential.

      Science.gov (United States)

      Parry, Ingrid S; Bagley, Anita; Kawada, Jason; Sen, Soman; Greenhalgh, David G; Palmieri, Tina L

      2012-06-01

      Commercially available interactive video games (IVG) like the Nintendo Wii™ (NW) and PlayStation™II Eye Toy (PE) are increasingly used in the rehabilitation of patients with burn. Such games have gained popularity in burn rehabilitation because they encourage range of motion (ROM) while distracting from pain. However, IVGs were not originally designed for rehabilitation purposes but rather for entertainment and may lack specificity for achieving rehabilitative goals. Objectively evaluating the specific demands of IVGs in relation to common burn therapy goals will determine their true therapeutic benefit and guide their use in burn rehabilitation. Upper extremity (UE) motion of 24 normal children was measured using 3D motion analysis during play with the two types of IVGs most commonly described for use after burn: NW and PE. Data was analyzed using t-tests and One-way Analysis of Variance. Active range of motion for shoulder flexion and abduction during play with both PE and NW was within functional range, thus supporting the idea that IVGs offer activities with therapeutic potential to improve ROM. PE resulted in higher demands and longer duration of UE motion than NW, and therefore may be the preferred tool when UE ROM or muscular endurance are the goals of rehabilitation. When choosing a suitable IVG for application in rehabilitation, the user's impairment together with the therapeutic attributes of the IVG should be considered to optimize outcome. Copyright © 2012 Elsevier Ltd and ISBI. All rights reserved.

    • Commercially available mobile phone headache diary apps: a systematic review.

      Science.gov (United States)

      Hundert, Amos S; Huguet, Anna; McGrath, Patrick J; Stinson, Jennifer N; Wheaton, Mike

      2014-08-19

      Headache diaries are often used by headache sufferers to self-monitor headaches. With advances in mobile technology, mobile electronic diary apps are becoming increasingly common. This review aims to identify and evaluate all commercially available mobile headache diary apps for the two most popular mobile phone platforms, iOS and Android. The authors developed a priori a set of 7 criteria that define an ideal headache diary app intended to help headache sufferers better understand and manage their headaches, while providing relevant data to health professionals. The app criteria were intended as minimum requirements for an acceptable headache diary app that could be prescribed by health care professionals. Each app was evaluated and scored against each criterion. Of the 38 apps identified, none of the apps met all 7 app criteria. The 3 highest scoring apps, meeting 5 of the app criteria, were iHeadache (developed by Better QOL), ecoHeadache (developed by ecoTouchMedia), and Headache Diary Pro (developed by Froggyware). Only 18% of the apps were created with scientific or clinical headache expertise and none of the apps reported on psychometric properties. Despite the growing market and demand, there is a concerning lack of scientific expertise and evidence base associated with headache diary apps.

    • Evaluation of commercial available fusion algorithms for Geoeye data

      Science.gov (United States)

      Vaiopoulos, Aristides D.; Nikolakopoulos, Konstantinos G.

      2013-10-01

      In this study ten commercial available fusion techniques and more especially the Ehlers, Gram-Schmidt, High Pass Filter, Local Mean Matching (LMM), Local Mean and Variance Matching (LMVM), Modified IHS (ModIHS), Pansharp, PCA, HCS (Hyperspherical Color Space) and Wavelet were used for the fusion of Geoeye panchromatic and multispectral data. The panchromatic data have a spatial resolution of 0.5m while the multispectral data have a spatial resolution of 2.0m. The optical result, the statistical parameters and different quality indexes such as ERGAS, Q, entropy were examined and the results are presented. The broader area of Pendeli mountain near to the city of Athens Greece and more especially two sub areas with different characteristics were chosen for the comparison. The first sub area is located at the edge of the urban fabric and combines at the same time the characteristics of an urban and a rural area. The second sub area comprises a large open quarry and it is suitable to examine which fused product is more suitable for mine monitoring.

    • Comprehensive characterization of commercially available canine training aids.

      Science.gov (United States)

      Tipple, Christopher A; Caldwell, Patricia T; Kile, Brian M; Beussman, Douglas J; Rushing, Blake; Mitchell, Natalie J; Whitchurch, Christian J; Grime, Martin; Stockham, Rex; Eckenrode, Brian A

      2014-09-01

      Effective and reliable training aids for victim recovery canine teams is essential for law enforcement and investigative purposes. Without adequate training aids, the rate of recovery for sub surface or surface human remains deposition using canine teams may be adversely affected and result in confusing information. The composition of three commercially available canine training aids that purportedly generate volatile components responsible for the odor of human decomposition is relatively simple and not closely related to those compounds experimentally determined to be present at the site of surface or sub-surface human remains. In this study, these different commercial formulations were chemically characterized using six different sampling approaches, including two applications of direct liquid injection, solid-phase microextraction (SPME), purge and trap, ambient preconcentration/thermal desorption, and cryogenic preconcentration/thermal desorption. Direct liquid injections resulted in the fewest number of detected compounds, while a cryogen based thermal desorption method detected the greatest number of compounds in each formulation. Based solely upon the direct liquid injection analysis, Pseudo™ Scent I was composed of approximately 29±4% and 71±5% of 2-pyrrolidinone and 4-aminobutanoic acid, respectively. This same analysis showed that Pseudo™ Scent II was composed of approximately 11±1, 11±1, 24±5, and 54±7% of putrescine, cadaverine, 2-pyrrolidinone, and 4-aminobutanoic acid, respectively. Headspace analysis was conducted to more closely simulate the process whereby a canine's nose would capture a volatiles profile. More compounds were detected using the headspace sampling method; however, the vast majority was not consistent with current data on human decomposition. Additionally, the three formulations were tested in outdoor and indoor scenarios by a double-blinded canine team, using a certified and specifically trained victim recovery canine

    • 'Female condoms give women greater control': a qualitative assessment of the experiences of commercial sex workers in Swaziland.

      Science.gov (United States)

      Mathenjwa, Thulile; Maharaj, Pranitha

      2012-10-01

      To explore commercial sex workers' experiences with the female condom in Swaziland. This is a qualitative study that draws on two focus group discussions and ten individual in-depth interviews with female commercial sex workers in Lavumisa, Swaziland. The findings suggest that the majority of female sex workers prefer to use the female condom with their clients because it offers them greater control over the sexual encounter. Other factors that facilitate its use include the absence of side effects, the enhancement of sexual pleasure and protection against the risk of STIs (including HIV). In addition, the women reported that the female condom is stronger and more resistant to breakage than the male condom. Moreover, the female condoms can be inserted well in advance of sexual intercourse. Difficulties of insertion, partner objection and limited product availability were some of the barriers to the use of the device. There was also a tendency to reuse the female condoms because of lack of product availability and privacy to insert it. Although female condom use involves negotiation with clients, the fact that it offers sex workers an independent method of protection gives them more power and also, increases their ability to control their sexual and reproductive health.

    • Low light illumination study on commercially available homojunction photovoltaic cells

      International Nuclear Information System (INIS)

      Russo, Johnny; Ray, William; Litz, Marc S.

      2017-01-01

      Highlights: • COTS PV cells are tested under indoor and narrow light spectra. • InGaP is the most efficient under low light conditions (0.5–100 μW_o_p_t/cm"2). • InGaP is selected for isotope battery. • Optimal incident wavelength (614 nm) for InGaP is identified in model. - Abstract: Low illumination (10"−"4 suns) and indoor light energy harvesting is needed to meet the demands of zero net energy (ZNE) building, Internet of Things (IoT), and beta-photovoltaic energy harvesting systems to power remote sensors. Photovoltaic (PV) solar cells under low intensity and narrow (±40 nm) light spectrum conditions are not well characterized nor developed, especially for commercially available devices and scalable systems. PV operating characteristics under 1 sun illumination decrease at lower light intensity and narrow spectrum conditions (efficiency drops from ∼25% at 100 mW_o_p_t/cm"2 to 2% at 1 μW_o_p_t/cm"2). By choosing a PV with a bandgap that matches the light source operating wavelength, the total system efficiency can be improved. By quantifying losses on homojunction photovoltaics (thermalization and leakage current), we have determined the theoretical optimized efficiency for a set of PV material and a selected set of light sources. We measure single-junction solar cells’ parameters under three different light sources (indoor light and narrow spectrum LED sources) with light intensities ranging from 0.5 to 100 μW_o_p_t/cm"2. Measurements show that indium gallium phosphide (InGaP) PV has the highest surface power density and conversion efficiency (29% under ≈1 μW_o_p_t/cm"2 from a 523 nm central peak LED). A beta-photovoltaic experimental study identifies InGaP to be optimized for use with the ZnS:Cu, Al and tritium at STP. The results have guided the selection of PV material for scalable isotope batteries and other low-light energy harvesting systems.

    • Evaluation of Commercially Available Cyanide Test Kits against Various Matrices

      Science.gov (United States)

      2016-08-01

      commercial products. This report may not be cited for purposes of advertisement . Acknowledgments The authors acknowledge the hard work...Sigma-Aldrich);  DG Clover Valley coffee creamer (Lot 09603235 9864 2048); and  Powdered milk ( Nestle ; Vevey, Switzerland). 2. PHASE I TESTING

    • Dose rate and SDD dependence of commercially available diode detectors

      International Nuclear Information System (INIS)

      Saini, Amarjit S.; Zhu, Timothy C.

      2004-01-01

      The dose-rate dependence of commercially available diode detectors was measured under both high instantaneous dose-rate (pulsed) and low dose rate (continuous, Co-60) radiation. The dose-rate dependence was measured in an acrylic miniphantom at a 5-cm depth in a 10x10 cm 2 collimator setting, by varying source-to-detector distance (SDD) between at least 80 and 200 cm. The ratio of a normalized diode reading to a normalized ion chamber reading (both at SDD=100 cm) was used to determine diode sensitivity ratio for pulsed and continuous radiation at different SDD. The inverse of the diode sensitivity ratio is defined as the SDD correction factor (SDD CF). The diode sensitivity ratio increased with increasing instantaneous dose rate (or decreasing SDD). The ratio of diode sensitivity, normalized to 4000 cGy/s, varied between 0.988 (1490 cGy/s)-1.023 (38 900 cGy/s) for unirradiated n-type Isorad Gold, 0.981 (1460 cGy/s)-1.026 (39 060 cGy/s) for unirradiated QED Red (n type), 0.972 (1490 cGy/s)-1.068 (38 900 cGy/s) for preirradiated Isorad Red (n type), 0.985 (1490 cGy/s)-1.012 (38 990 cGy/s) for n-type Pt-doped Isorad-3 Gold, 0.995 (1450 cGy/s)-1.020 (21 870 cGy/s) for n-type Veridose Green, 0.978 (1450 cGy/s)-1.066 (21 870 cGy/s) for preirradiated Isorad-p Red, 0.994 (1540 cGy/s)-1.028 (17 870 cGy/s) for p-type preirradiated QED, 0.998 (1450 cGy/s)-1.003 (21 870 cGy/s) for the p-type preirradiated Scanditronix EDP20 3G , and 0.998 (1490 cGy/s)-1.015 (38 880 cGy/s) for Scanditronix EDP10 3G diodes. The p-type diodes do not always show less dose-rate dependence than the n-type diodes. Preirradiation does not always reduce diode dose-rate dependence. A comparison between the SDD dependence measured at the surface of a full scatter phantom and that in a miniphantom was made. Using a direct adjustment of radiation pulse height, we concluded that the SDD dependence of diode sensitivity can be explained by the instantaneous dose-rate dependence if sufficient buildup is

  1. Are commercially available nanoparticles safe when applied to the skin?

    Science.gov (United States)

    Robertson, Thomas A; Sanchez, Washington Y; Roberts, Michael S

    2010-10-01

    There are a growing number of commercial uses of nanoparticles which involve direct people contact with the potential for absorption through the skin. Nanoparticles are present in a range of consumer products including colloidal health drinks, carbon fibre sports equipment, sunscreens, cosmetics, electronic products and as antibacterial components of toys, cooking products and wound dressings. Environmental sources of ultra-fine nanoparticles have been present for millennia and anthropogenic sources of similar materials result from industrial processes. Recent technological advances have enabled improvements in both the manufacture of nanoparticles and in the study of their safety. With subcellular dimensions, the physical properties of a nanoparticle cannot be easily predicted from the properties of a microparticle with identical chemical composition. Recent studies in animals and humans have sought to document the safety of consumer nanomaterials. In this article, the safety of such materials is critically reviewed.

  2. Bioactive small molecules in commercially available cereal food

    DEFF Research Database (Denmark)

    Steffensen, Stine K.; Adhikari, Khem B.; Laursen, Bente B.

    2017-01-01

    processes. The concentrations of 11 BX compounds were determined by liquid chromatography–triple quadrupole mass spectrometry (LC–MS/MS) in 25 supermarket-available cereal food products. The total BX content varied from below the limit of detection to >500 μg/g dry matter (DM) with some degree of variation...

  3. Reactive lysine content in commercially available pet foods

    NARCIS (Netherlands)

    Rooijen, van C.; Bosch, G.; Poel, van der A.F.B.; Wierenga, P.A.; Alexander, L.; Hendriks, W.H.

    2014-01-01

    The Maillard reaction can occur during processing of pet foods. During this reaction, the e-amino group of lysine reacts with reducing sugars to become unavailable for metabolism. The aim of the present study was to determine the reactive lysine (RL; the remaining available lysine) to total lysine

  4. 78 FR 65703 - Notice of Availability of the Idaho and Southwestern Montana Greater Sage-Grouse Draft Land Use...

    Science.gov (United States)

    2013-11-01

    ...] Notice of Availability of the Idaho and Southwestern Montana Greater Sage-Grouse Draft Land Use Plan... Environmental Impact Statement (EIS) for managing Greater Sage- Grouse (GRSG) in the Idaho and Southwestern... Southwestern Montana Greater Sage-Grouse Draft LUP Amendments/Draft EIS by any of the following methods: Email...

  5. 78 FR 50088 - Notice of Availability of the Northwest Colorado Greater Sage-Grouse Draft Resource Management...

    Science.gov (United States)

    2013-08-16

    ... Availability of the Northwest Colorado Greater Sage- Grouse Draft Resource Management Plan Amendment and Draft... Land Management (BLM) has prepared a Northwest Colorado Greater Sage-Grouse Draft Resource Management.../or mailings. ADDRESSES: You may submit comments related to the Northwest Colorado Greater Sage-Grouse...

  6. FLUORIDE CONTENT OF COMMERCIALLY AVAILABLE SOY MILK PRODUCTS IN THAILAND.

    Science.gov (United States)

    Rirattanapong, Opas; Rirattanapong, Praphasri

    2016-01-01

    Abstract. In Thailand, the consumption of soy milk products is common but there is limited data about their fluoride content. The purpose of this study was to es- timate the fluoride content of soy milk products available in Thailand. Fluoride content was determined for 76 brands of soy milk using a F-ion-specific electrode. The fluoride concentrations ranged from 0.01 to 3.78 μg/ml. The fluoride content was not related to sugar content, soy bean content or the sterilization process. Among 3 brands of soy milk containing tea powder extract, the fluoride content was high (1.25 to 3.78 μg/ml). Most brands of soy milk tested in our study had fluoride content below the optimal daily intake but brands containing tea powder extract if consumed by children may increase their risk for fluorosis.

  7. Performance of commercially available solar and heat pump water heaters

    International Nuclear Information System (INIS)

    Lloyd, C.R.; Kerr, A.S.D.

    2008-01-01

    Many countries are using policy incentives to encourage the adoption of energy-efficient hot water heating as a means of reducing greenhouse gas emissions. Such policies rely heavily on assumed performance factors for such systems. In-situ performance data for solar and heat pump hot water systems, however, are not copious in the literature. Otago University has been testing some systems available in New Zealand for a number of years. The results obtained are compared to international studies of in-situ performance of solar hot water systems and heat pump hot water systems, by converting the results from the international studies into a single index suitable for both solar and heat pump systems (COP). Variability in the international data is investigated as well as comparisons to model results. The conclusions suggest that there is not too much difference in performance between solar systems that have a permanently connected electric boost backup and heat pump systems over a wide range of environmental temperatures. The energy payback time was also calculated for electric boost solar flat plate systems as a function of both COP and hot water usage for a given value of embodied energy. The calculations generally bode well for solar systems but ensuring adequate system performance is paramount. In addition, such systems generally favour high usage rates to obtain good energy payback times

  8. Operational Characteristics of Four Commercially Available Personal Cooling Vests

    Science.gov (United States)

    Ku, Yu-Tsuan E.; Montgomery, Leslie D.; Lee, Hank C.; Webbon, Bruce W.; Kliss, Mark (Technical Monitor)

    1997-01-01

    Personal thermoregulatory systems which provide chest cooling are used in the industrial and aerospace environments to alleviate thermal stress. However, little information is available regarding the physiologic and circulatory changes produced by routine operation of these systems. The objectives of this study were to compare the effectiveness of two passive and two active cooling vests, and to measure the body temperature and circulatory changes produced by each cooling vest configuration. The MicroClimate Systems and the Life Enhancement Tech(LET) lightweight liquid cooling vests, the Steele Vest and LET's Zipper Front Garment were used to cool the chest region of 11 male and 10 female subjects (25 to 55 yr.) in this study. Calf, forearm and finger blood flows were measured using a tetrapolar impedance rheograph. The subjects, seated in an upright position at normal room temperature (approx.21 C), were tested for 60 min. with the cooling system operated at its maximum cooling capacity. Blood flows were recorded continuously using a computer data acquisition system with a sampling frequency of 250 Hz. Oral, right and left ear temperatures and cooling system parameters were logged manually every 5 min. Arm, leg, chest and rectal temperatures; heart rate; respiration; and an activity index were recorded continuously on a URI Inc. Biolog ambulatory monitor. In general, the male and female subjects' rectal and ear temperature responses to cooling were similar for all vest configurations tested. Oral temperatures during the recovery period were significantly (Pcooling and recovery periods. These results show that all vest configurations elicit a similar thermal response in both male and female subject groups. However, subject population variance was rather large and may have masked differences between the vests. One vest may prove more effective than another for a given individual, and experience is the only means of determining this.

  9. Efficacy of two commercially available dentifrices in reducing dentinal hypersensitivity

    Directory of Open Access Journals (Sweden)

    Prasad KVV

    2010-01-01

    Full Text Available Objective: A parallel design clinical study evaluated reduction in hypersensitivity after brushing for 12 weeks with Anchor toothpaste (containing potassium citrate, zinc citrate, triclosan and sodium monofluorophosphate (test and Colgate Total (sodium fluoride, silica, triclosan and copolymer (control dentifrices. Materials and Methods: Sixty adults with sensitivity to hot and cold stimulus in at least two tooth surfaces were stratified at the baseline examination by tactile, hot and cold stimuli scores in two balanced groups. Subjects were randomly allocated the test and control dentifrices and evaluated after 6 and 12 weeks of dentifrice use for hypersensitivity. Results: The two teeth that were selected in each patient were designated as two different sets. The 12 th -week scores as compared to baseline scores for tactile, heat and cold tests in the test group showed a reduction in tooth hypersensitivity by 36.67% (P < 0.01, 20.35% (P < 0.01 and 53.64 % (P < 0.01, respectively, in the first set of teeth and 43.75% (P < 0.01, 24.48% (P < 0.01 and 59.78% (P < 0.01, respectively, in the second set of teeth. The 12 th -week scores as compared to baseline scores for tactile, heat and cold tests in the control group showed a reduction in tooth hypersensitivity by 42.86% (P < 0.01, 13.02% (P < 0.01 and 45.14% (P < 0.01, respectively, in the first set of teeth and 40% (P < 0.01, 16.59% (P < 0.01 and 44.16% (P < 0.01, respectively, in the second set of teeth. Conclusions: Both the products reduced dentinal hypersensitivity in the study subjects at the end of the 12-week period. However, there was no statistically significant difference in reduction in hypersensitivity between the two products.

  10. Are commercially available essential oils from Australian native plants repellent to mosquitoes?

    Science.gov (United States)

    Maguranyi, Suzann K; Webb, Cameron E; Mansfield, Sarah; Russell, Richard C

    2009-09-01

    While the use of topical insect repellents, particularly those containing synthetic active ingredients such as deet (N,N-diethyl-3-methylbenzamide), are a mainstay in personal protection strategies emphasized in public health messages, there is a growing demand in the community for alternative repellents, particularly those of botanical origin and thus deemed to be "natural." This study evaluated the repellency of essential oils from 11 Australian native plants in 5% v/v formulations against Aedes aegypti, Culex quinquefasciatus, and Culex annulirostris under laboratory conditions. A blend of the top 3 performing oils was then compared with deet and a commercially available botanical insect repellent. All essential oils provided at least some protection against the 3 mosquito species, with the longest protection time (110 min) afforded by Prostanthera melissifolia against Cx. quinquefasciatus. Mean protection times against Ae. aegypti were substantially lower than those for the Culex spp. tested. Deet provided significantly longer protection against Ae. aegypti than both the 5% v/v blend of Leptospermum petersonii, Prostanthera melissifolia, and Melaleuca alternifolia (the 3 most effective oils) and the commercial botanical repellent. The results of this study indicate that these essential oils from Australian native plants offer limited protection against biting mosquitoes and that a blend of essential oils holds may offer commercial potential as a short-period repellent or under conditions of low mosquito abundance. However, it is important that public health messages continue to emphasize the greater effectiveness of deet-based repellents in areas with risks of mosquito-borne disease.

  11. Fast Food in the Greater Accra Region of Ghana: Characteristics, Availability and the Cuisine Concept

    NARCIS (Netherlands)

    Omari, R.; Jongerden, J.P.; Essegbey, G.; Frempong, G.; Ruivenkamp, G.T.P.

    2013-01-01

    Fast food has been extensively debated but most studies have focused on one or two of its characteristics. Using the cuisine concept, we propose a more comprehensive approach to the study of fast food characteristics and availability, while taking cultural context into account. The objectives of

  12. 78 FR 18561 - Determination Under the Textile and Apparel Commercial Availability Provision of the United...

    Science.gov (United States)

    2013-03-27

    ...: Authority: The US-Colombia TPA; Section 203(o)(4) of the United States-Colombia Trade Promotion Agreement... Commercial Availability Provision of the United States-Colombia Trade Promotion Agreement (``US-Colombia TPA... Under the Commercial Availability Provision of the United States-Colombia Trade Promotion Agreement, 77...

  13. A Study of IR Loss Correction Methodologies for Commercially Available Pyranometers

    Energy Technology Data Exchange (ETDEWEB)

    Long, Chuck; Andreas, Afshin; Augustine, John; Dooraghi, Mike; Habte, Aron; Hall, Emiel; Kutchenreiter, Mark; McComiskey, Allison; Reda, Ibrahim; Sengupta, Manajit

    2017-03-24

    This presentation provides a high-level overview of a study of IR Loss Connection Methodologies for Commercially Available Pyranometers. The IR Loss Corrections Study is investigating how various correction methodologies work for several makes and models of commercially available pyranometers in common use, both when operated in ventilators with DC fans and without ventilators, as when they are typically calibrated.

  14. Exploring the 'permanent forest' paradigm: might renewable commercial forest estates lead to greater net greenhouse abatement over the longer term?

    International Nuclear Information System (INIS)

    Anderson, Graeme

    2007-01-01

    products that have a higher greenhouse footprint. Understanding both is a critical element in determining the contribution forestry can make to our greenhouse challenge. Carbon owners and commercial forest growers have much in common: As an off-site carbon owner, it is reassuring to know the forest owner actually has a major stake in the forest's management and survival. They seek to manage, measure and protect their forest asset, and will have insurance, biosecurity and risk management and forest replenishment processes in place. There are also important inter-generational effects to consider, where commercial forests offer an advantage. In closing, commercial plantations can deliver genuine long term abatement plus a range of landscape and social benefits over successive generations - and should form a greater part of Australia's response to our greenhouse challenge

  15. Nutritional analysis and microbiological evaluation of commercially available enteral diets for cats.

    Science.gov (United States)

    Prantil, Lori R; Markovich, Jessica E; Heinze, Cailin R; Linder, Deborah E; Tams, Todd R; Freeman, Lisa M

    2016-01-01

    To determine the prevalence of nutrients less than or greater than accepted standards in commercially available enteral diets for cats, and to identify contamination incidence in enteral diets for cats. Prospective cross-sectional study. University teaching hospital. Seven commercial enteral diets for cats. Labels were evaluated to determine if diets were intended to be nutritionally complete and balanced. One diet under storage techniques partially representative of clinical conditions was sampled on days 0, 1, 3, 5, and 7 of storage for aerobic bacterial culture. All 7 diets were analyzed for key nutrients and results were compared to Association of American Feed Control Officials (AAFCO) Nutrient Profiles for Adult Cats for maintenance and National Research Council recommended allowance (NRC-RA). From label information, 4 diets were classified as complete and balanced and 3 diets were classified as not complete and balanced. All 7 diets had at least 1 nutrient less than the AAFCO minimums and the NRC-RA. The total number of nutrients less than AAFCO minimums ranged from 3 to 9 (median = 4), with iron, potassium, and manganese being the most common. Concentrations of some nutrients were undetectable. None of the samples tested had a positive aerobic culture at baseline (day 0) or on subsequent samples from days 1, 3, 5, and 7 under any storage condition. None of the diets analyzed met all of the minimum nutrient concentrations. While short-term feeding may not be of concern for an individual patient, clinicians should be aware of potential nutritional limitations when feeding enteral diets to ill or injured cats. © Veterinary Emergency and Critical Care Society 2015.

  16. Principles of commercially available pretreatment and feeding equipment for baled biomass

    Energy Technology Data Exchange (ETDEWEB)

    Koch, T. [Thomas Koch Energi, Vanloese (Denmark); Hummelshoej, R.M. [COWIconsult, Lyngby (Denmark)

    1993-12-31

    During the last 15 years, there has been a growing interest in utilizing waste biomass for energy production in Denmark. Since 1990, it has been unlawful to burn surplus straw on open land. Before the year 2000, it is intended to utilize most of the 2--3 million tons of surplus straw as an energy resource. The type of plants that were built in the beginning were combustion plants for district heating. The feeding equipment for these plants has been developed to an acceptable standard. Later, combustion plants for combined heat and power production based on a steam turbine were introduced. This type of plant demands a much greater continuity in the fuel flow, and the consequences of minor discontinuities are to be dropped from the grid. Gasification and pyrolysis demands a high sealing ability of the feeding equipment, because of the explosive and poisonous gas in the plant and a need for a very high continuity in the fuel feed. The first plants were built with the equipment and experiences from the farming industries, which have a long tradition in working with biomass-handling. The experiences gained with this type of equipment were not very promising, and in the early eighties, a more industrial type of biomass-handling equipment was developed. This paper presents the principles of the heavy-duty biomass pretreatment and feeding equipment that was commercially available in Denmark in May, 1993.

  17. 76 FR 13396 - Notice of Availability of the Draft Environmental Impact Statement for the Mountaineer Commercial...

    Science.gov (United States)

    2011-03-11

    ... DEPARTMENT OF ENERGY Notice of Availability of the Draft Environmental Impact Statement for the... potential environmental impacts of a project proposed by American Electric Power (AEP) Service Corporation...) announces the availability of the Draft Environmental Impact Statement for the Mountaineer Commercial Scale...

  18. Attention and Cognitive Bias Modification Apps: Review of the Literature and of Commercially Available Apps

    Science.gov (United States)

    Ying, JiangBo; Song, Guo; Fung, Daniel SS; Smith, Helen

    2018-01-01

    Background Automatic processes, such as attentional biases or interpretative biases, have been purported to be responsible for several psychiatric disorders. Recent reviews have highlighted that cognitive biases may be modifiable. Advances in eHealth and mHealth have been harnessed for the delivery of cognitive bias modification. While several studies have evaluated mHealth-based bias modification intervention, no review, to our knowledge, has synthesized the evidence for it. In addition, no review has looked at commercial apps and their functionalities and methods of bias modification. A review is essential in determining whether scientifically validated apps are available commercially and the proportion of commercial apps that have been evaluated scientifically. Objective The objective of this review was primarily to determine the proportion of attention or cognitive bias modification apps that have been evaluated scientifically and secondarily to determine whether the scientifically evaluated apps were commercially available. We also sought to identify commercially available bias modification apps and determine the functionalities of these apps, the methods used for attention or cognitive bias modification, and whether these apps had been evaluated scientifically. Methods To identify apps in the published literature, we searched PubMed, MEDLINE, PsycINFO, and Scopus for studies published from 2000 to April 17, 2018. The search terms used were “attention bias” OR “cognitive bias” AND “smartphone” OR “smartphone application” OR “smartphone app” OR “mobile phones” OR “mobile application” OR mobile app” OR “personal digital assistant.” To identify commercial apps, we conducted a manual cross-sectional search between September 15 and 25, 2017 in the Apple iTunes and Google Play app stores. The search terms used to identify the apps were “attention bias” and “cognitive bias.” We also conducted a manual search on the apps with

  19. Parasitization of commercially available parasitoid species against the lettuce aphid, Nasonovia ribisnigri (Hemiptera: Aphididae).

    Science.gov (United States)

    Shrestha, G; Skovgård, H; Enkegaard, A

    2014-12-01

    The lettuce aphid, Nasonovia ribisnigri (Mosley), is an economically important pest of lettuce worldwide. Little documentation exists for the control efficacy of aphid parasitoids against N. ribisnigri. This laboratory study evaluated three commercially available parasitoid species: Aphidius colemani (Viereck), Lysiphlebus testaceipes (Cresson), and Aphelinus abdominalis (Dalman) for their mortality impact on N. ribisnigri. The green peach aphid Myzus persicae (Sulzer) was included as a reference aphid. The study showed that A. abdominalis successfully parasitized 39 and 13% of the offered N. ribisnigri and M. persicae, respectively, within a 24-h exposure period. In contrast, none of the lettuce aphids exposed to Ap. colemani or L. testaceipes were successfully parasitized, whereas 60 and 3.5% of M. persicae, respectively, were successfully parasitized within a 6-h exposure period. Lettuce aphid mortality due to incomplete parasitization was 26 and 31% when exposed to Ap. colemani and L. testaceipes, respectively, with corresponding values for M. persicae being 5 and 10%, respectively. Mortality as a result of incomplete parasitization when aphids were exposed to A. abdominalis was low for both aphid species. The total mortality inflicted by A. abdominalis within a 24-h exposure period was 51% for the lettuce aphids and significantly less (19%) for green peach aphids. In contrast, Ap. colemani inflicted a higher mortality in M. persicae (65%) compared with N. ribisnigri (26%) within a 6-h exposure period. L. testaceipes caused a greater mortality in N. ribisnigri as compared with M. persicae. This study concludes that A. abdominalis has the potential to be used against N. ribisnigri in inoculative biocontrol programs as compared with the other parasitoid species based on successful parasitization.

  20. Offsite commercial disposal of oil and gas exploration and production waste :availability, options, and cost.

    Energy Technology Data Exchange (ETDEWEB)

    Puder, M. G.; Veil, J. A.

    2006-09-05

    A survey conducted in 1995 by the American Petroleum Institute (API) found that the U.S. exploration and production (E&P) segment of the oil and gas industry generated more than 149 million bbl of drilling wastes, almost 18 billion bbl of produced water, and 21 million bbl of associated wastes. The results of that survey, published in 2000, suggested that 3% of drilling wastes, less than 0.5% of produced water, and 15% of associated wastes are sent to offsite commercial facilities for disposal. Argonne National Laboratory (Argonne) collected information on commercial E&P waste disposal companies in different states in 1997. While the information is nearly a decade old, the report has proved useful. In 2005, Argonne began collecting current information to update and expand the data. This report describes the new 2005-2006 database and focuses on the availability of offsite commercial disposal companies, the prevailing disposal methods, and estimated disposal costs. The data were collected in two phases. In the first phase, state oil and gas regulatory officials in 31 states were contacted to determine whether their agency maintained a list of permitted commercial disposal companies dedicated to oil. In the second stage, individual commercial disposal companies were interviewed to determine disposal methods and costs. The availability of offsite commercial disposal companies and facilities falls into three categories. The states with high oil and gas production typically have a dedicated network of offsite commercial disposal companies and facilities in place. In other states, such an infrastructure does not exist and very often, commercial disposal companies focus on produced water services. About half of the states do not have any industry-specific offsite commercial disposal infrastructure. In those states, operators take their wastes to local municipal landfills if permitted or haul the wastes to other states. This report provides state-by-state summaries of the

  1. Infiltration of commercially available, anode supported SOFC’s via inkjet printing

    NARCIS (Netherlands)

    Mitchell-Williams, T.B.; Tomov, R.I.; Saadabadi, S.A.; Krauz, M.; Purushothaman Vellayani, A.; Glowacki, B.A.; Kumar, R.V.

    2017-01-01

    Commercially available anode supported solid oxide fuel cells (NiO-8YSZ/8YSZ/LSCF- 20 mm in diameter) were anode infiltrated with gadolinium doped ceria (CGO) using a scalable drop-on-demand inkjet printing process. Cells were infiltrated with two different precursor solutions—water based or

  2. A transfer technique for high mobility graphene devices on commercially available hexagonal boron nitride

    NARCIS (Netherlands)

    Zomer, P. J.; Dash, S. P.; Tombros, N.; van Wees, B. J.

    2011-01-01

    We present electronic transport measurements of single and bilayer graphene on commercially available hexagonal boron nitride. We extract mobilities as high as 125 000 cm(2) V-1 s(-1) at room temperature and 275 000 cm(2) V-1 s(-1) at 4.2 K. The excellent quality is supported by the early

  3. Assessment of the use of two commercially available environmental enrichments by laboratory mice by preference testing.

    NARCIS (Netherlands)

    Loo, P.L. van; Blom, H.J.; Meijer, M.K.; Baumans, V.

    2005-01-01

    In the field of biomedical research, the demand for standardization of environmental enrichment for laboratory animals is growing. For laboratory mice, a wide variety of environmental enrichment items are commercially available. Most of these comply with the demands for standardization, hygiene and

  4. 78 FR 11159 - Determination under the Textile and Apparel Commercial Availability Provision of the Dominican...

    Science.gov (United States)

    2013-02-15

    ....25 for fabrics, yarns, and fibers that the Parties to the CAFTA-DR Agreement have determined are not... States determines that a fabric, yarn, or fiber is not available in commercial quantities in a timely... consisting of a 3-layered fleece/ shell construction, woven outer layer and brushed inner layer, bonded with...

  5. 77 FR 16001 - Interim Procedures for Considering Requests Under the Commercial Availability Provision of the...

    Science.gov (United States)

    2012-03-19

    ..., fiber content, construction, yarn size, and finishing processes; and the classification of the product... specifications, including, if applicable, fiber content, construction, yarn size, and may include a finishing... requests to modify the list of fibers, yarns, or fabrics not available in commercial quantities in a timely...

  6. Estimation of fluoride levels in various commercially available carbonated soft drinks in Chandigarh city, India

    Directory of Open Access Journals (Sweden)

    Mohit Bansal

    2015-01-01

    Full Text Available Introduction: Fluoride has a preventive action on dental caries. However, Excessive ingestion of fluoride from different sources can lead to the development of dental fluorosis. Aim: To estimate fluoride levels in various commercially available carbonated soft drinks available in Chandigarh city. Materials and Methods: Twelve different brands of commercially available soft drinks were purchased from three different places and divided into three groups. Fluoride levels were estimated using fluoride test strips Quantofix 37211 Fluka; Sigma-Aldrich. Results: Fluoride levels ranged from 0.12 to 0.42 mg/dl F with the maximum level in Thumbs up and least in Diet Pepsi. Conclusion: The levels of fluoride varied in various carbonated soft drinks analyzed. This could contribute significantly to the total fluoride intake from all sources and thus be an important risk factor for the development of dental fluorosis.

  7. Determination of 210Po concentration in commercially available infant formulae and assessment of daily ingestion dose

    OpenAIRE

    Prabhath, Ravi K.; Sreejith, Sathyapriya R.; Nair, Madhu G.; Rao, D.D.; Pradeepkumar, K.S.

    2015-01-01

    A study has been conducted to estimate the concentration of natural radioactive polonium in commercially available packaged infant food formulae available in Mumbai, India and the corresponding daily dose normalized based on its shelf life. Eleven most popular international brands of infant formulae were sourced from market and three aliquots from each sample were analysed for concordant results. Autodeposition method onto a silver planchet from hot dilute acid solution followed by alpha spec...

  8. Control/interlock/display system for EBT-P using commercially-available hardware and firmware

    International Nuclear Information System (INIS)

    Schmitt, R.J.

    1983-01-01

    For the EBT-P project, alternative commercially-available hardware, software and firmware have been employed for control, interlock and data display functions. This paper describes the criteria and rationale used to select that commercial equipment and discusses the important features of the equipment chosen, especially programmable controllers. Additional discussion is centered on interface problems which are encountered upon attempts to integrate equipment from several vendors. Some solutions to these problems are discussed. Details of software and hardware performance during tests are presented. The extent to which the EBT-P hardware and software configuration addresses and resolves various issues is discussed. Several areas have been uncovered in which relatively slight improvements/modifications of commercial programmable controller firmware would significantly improve the capability of this type of hardware in fusion control applications. These improvements are discussed in detail

  9. Stability of Commercially Available Macular Carotenoid Supplements in Oil and Powder Formulations

    Directory of Open Access Journals (Sweden)

    David Phelan

    2017-10-01

    Full Text Available We previously identified that the concentration of zeaxanthin in some commercially available carotenoid supplements did not agree with the product’s label claim. The conclusion of this previous work was that more quality assurance was needed to guarantee concordance between actual and declared concentrations of these nutrients i.e., lutein (L zeaxanthin (Z and meso-zeaxanthin (MZ in commercially available supplements. Since this publication, we performed further analyses using different commercially available macular carotenoid supplements. Three capsules from one batch of eight products were analysed at two different time points. The results have been alarming. All of the powder filled products (n = 3 analysed failed to comply with their label claim (L: 19–74%; Z: 57–73%; MZ: 83–97%; however, the oil filled soft gel products (n = 5 met or were above their label claim (L: 98–122%; Z: 117–162%; MZ: 97–319%. We also identified that the carotenoid content of the oil filled capsules were stable over time (e.g., L average percentage change: −1.7%, but the powder filled supplements degraded over time (e.g., L average percentage change: −17.2%. These data are consistent with our previous work, and emphasize the importance of using carotenoid interventions in oil based formulas rather than powder filled formulas.

  10. Determination of essential and toxic elements in commercially available fruit juices

    International Nuclear Information System (INIS)

    Yawar, W.; Rahman, S.

    1997-01-01

    A study has been carried out for the determination of Cr, Pb, Fe in different varieties of commercially available packed fruit juices like apple, mango orange and mixed flavour by using flame and electrothermal atomic absorption spectrophotometric technique. These juices are available at a reasonable price and are commonly used by public. Like many other articles the baseline levels of essential and toxic elements in Pakistani fruit juices are generally not available. It was, therefore, considered to monitor the levels of essential as well toxic elements in the juices. Hence a variety of juices was collected from local market and measurements of the above mentioned elements were made. (author)

  11. A comparison of resistance to fracture among four commercially available forms of hydroxyapatite cement.

    Science.gov (United States)

    Miller, Lee; Guerra, Aldo Benjamin; Bidros, Rafi Sirop; Trahan, Christopher; Baratta, Richard; Metzinger, Stephen Eric

    2005-07-01

    Hydroxyapatite cement is a relatively new biomaterial that has found widespread use in craniomaxillofacial surgery. Despite its common usage, complication rates as high as 32% have been reported. When failed implants are removed, implant fracture has been cited as a potential cause of failure. The purpose of this study was to evaluate resistance to fracture among 4 commercially available hydroxyapatite cement formulations. The materials tested included Norian Craniofacial Repair System (carbonated apatite cement) (AO North America, Devon, PA), Norian CRS Fast Set Putty (carbonated apatite cement) (AO North America), BoneSource (hydroxyapatite cement) (Stryker Leibinger, Portage, MI), and Mimix (hydroxyapatite cement) (Walter Lorenz Surgical, Inc, Jacksonville, FL). To ensure consistency, all materials were embedded in acrylic wells. Each material was placed into a well 2.54 cm in diameter and 0.953 cm in thickness. The materials were prepared per manufacturer specifications. All materials were incubated at 37.0 degrees C, in 6% CO2, 100% humidity for 36 hours. Using the Bionix MTS Test System, a 12-mm-diameter probe applied incremental force to the center of the disk at a rate of 0.1 mm per second. The transmitted force was measured using a Bionix MTS Axial-Torsional Load Transducer for each disk. The force which resulted in fracture was recorded for each material. Ten disks of each material were processed by this method, for a total of 40 disks. The significance of resistance to fracture for the 4 compounds was analyzed using 1-way analysis of variance with post hoc Scheffe method. Mean fracture force with related P values was plotted for direct comparison of group outcomes. Material type contributed significantly to variance in fracture force for the biomaterials studied. Norian CRS required the greatest mean fracture force (1385 N, SD+/-292 N), followed by Norian CRS Fast Set Putty (1143 N, SD+/-193 N). Mimix required a mean fracture force of 740 N, SD+/-79 N

  12. Use of commercially available rabbit monoclonal antibodies for immunofluorescence double staining

    DEFF Research Database (Denmark)

    Bzorek, M.; Stamp, I.M.; Frederiksen, L.

    2008-01-01

    Immunohistochemistry, that is, the use of polyclonal and monoclonal antibodies to detect cell and tissue antigens at a microscopical level is a powerful tool for both research and diagnostic purposes. Especially in the field of hematologic disease, there is often a need to detect several antigens...... synchronously, and we report here a fast and easy technique for demonstrating more than 1 antigen in 1 slide using immunofluorescence. We have used commercially available rabbit monoclonal antibodies (Cyclin D1, CD3, CD5, CD23, etc.) paired with mouse monoclonal antibodies (CD7, CD20, CD79a, Pax-5, etc.......) for double immunofluorescence labeling on paraffin-embedded tissue sections. Commercially available rabbit monoclonal antibodies in combination with mouse monoclonal antibodies proved useful in double immunofluorescence labeling on paraffin-embedded tissue, and all combinations used yielded excellent results...

  13. Applicability of Commercially Available ELISA Kits for the Quantification of Faecal Immunoreactive Corticosterone Metabolites in Mice

    DEFF Research Database (Denmark)

    Abelson, Klas S P; Kalliokoski, Otto; Teilmann, Anne Charlotte

    2016-01-01

    Background: Commercially available ELISA kits are popular among investigators that quantify faecal corticosterone or cortisol metabolites (FCM) for stress assessment in animals. However, in faeces, these assays mainly detect immunoreactive glucocorticoid metabolites. Since different assays contain......: The present study was designed to investigate corticosterone (CORT) in serum and FCM levels in faeces of laboratory mice, as quantified in four different ELISA kits (DRG EIA-4164, Demeditec DEV9922, Enzo ADI-900-097 and Cayman EIA kit 500655). Assay kits were chosen based on the origin of the antibody...... assays, in both groups of mice. In faecal samples, there was no consistent positive correlation between the levels detected in the four assays and the measured concentration of FCM also differed between assays. Conclusion: Whereas commercially available CORT ELISAs are frequently successfully used...

  14. Analysis of Two Commercially Available Bortezomib Products: Differences in Assay of Active Agent and Impurity Profile

    OpenAIRE

    Byrn, Stephen R.; Tishmack, Patrick A.; Milton, Mark J.; van de Velde, Helgi

    2011-01-01

    The analytical properties of two commercially available bortezomib products (VELCADE® and Bortenat) were compared using nuclear magnetic resonance, mass spectrometry, high-performance liquid chromatography, and gas chromatography. The data showed differences between the two products. Based on these data, Bortenat samples contained more active ingredients than indicated by the label (mean, 116.5% and 117.9% of label, in 2-mg and 3.5-mg vials, respectively). In comparison, VELCADE samples conta...

  15. Implanted cardiac devices are reliably detected by commercially available metal detectors

    DEFF Research Database (Denmark)

    Holm, Katja Fiedler; Hjortshøj, Søren Pihlkjær; Pehrson, Steen

    2013-01-01

    Explosions of Cardiovascular Implantable Electronic Devices (CIEDs) (pacemakers, defibrillators, and loop recorders) are a well-recognized problem during cremation, due to lithium-iodine batteries. In addition, burial of the deceased with a CIED can present a potential risk for environmental...... contamination. Therefore, detection of CIEDs in the deceased would be of value. This study evaluated a commercially available metal detector for detecting CIEDs....

  16. Comparative study of the swabbing properties of seven commercially available swab materials for cleaning verification.

    Science.gov (United States)

    Corrigan, Damion K; Piletsky, Sergey; McCrossen, Sean

    2009-01-01

    This article compares the technical performances of several different commercially available swabbing materials for the purpose of cleaning verification. A steel surface was soiled with solutions of acetaminophen, nicotinic acid, diclofenac, and benzamidine and wiped with each swabbing material. The compounds were extracted with water or ethanol (depending on polarity of analyte) and their concentration in extract was quantified spectrophotometrically. The study also investigated swab debris on the wiped surface. The swab performances were compared and the best swab material was identified.

  17. Development of a charge-sensitive preamplifier using commercially available components

    International Nuclear Information System (INIS)

    Fagionato, Esnel A.; Genezini, Frederico A.; Zahn, Guilherme S.

    2013-01-01

    Signals produced in radiation detectors are very fast and with low intensity; these signals are not able to directly excite a regular MCA multichannel circuit, so some sort of amplification is needed. This work proposes the construction of a nuclear detector preamplifier using commercially available components that are not specifically designed for the use in nuclear instrumentation. The preamplifier was then tested and its performance was compared to that of an Ortec 142 preamplifier. (author)

  18. Composition, disintegrative properties, and labeling compliance of commercially available taurine and carnitine dietary products.

    Science.gov (United States)

    Bragg, Rebecca R; Freeman, Lisa M; Fascetti, Andrea J; Yu, Zengshou

    2009-01-15

    To test the quality, disintegration properties, and compliance with labeling regulations for representative commercially available taurine and carnitine dietary products. Evaluation study. 11 commercially available taurine and 10 commercially available carnitine products. For each product, the amount of taurine or carnitine was determined and compared with the label claim. All products were evaluated for concentrations of mercury, arsenic, and selenium. Disintegration properties of 5 taurine and 8 carnitine products were determined in vitro. Labels were evaluated for compliance with FDA guidelines. 10 of 11 taurine and 10 of 10 carnitine products were within 10% of the stated label claim. Three of 11 taurine and 6 of 10 carnitine products were within 5% of the stated label claim. The median percentage difference between laboratory analysis and label claim was -5.7% (range, -26.3% to 2.5%) for taurine and 3.6% (range, -2.6% to 8.8%) for carnitine. No substantial amount of contamination with mercury, arsenic, or selenium was found in any of the products. During disintegration testing, 1 of 5 taurine products and 5 of 8 carnitine products did not disintegrate within 45 minutes during at least 1 test. Disintegration time for those that did disintegrate ranged from 1.7 to 37.0 minutes. All product labels conformed with FDA regulations. Taurine and carnitine products evaluated in this study closely adhered to manufacturer claims and labeling guidelines. However, disintegration testing suggested high variability in some products, possibly limiting uptake and use by animals that receive them.

  19. Property comparisons of commercially available silica-based microporous insulations I. Machinability and thermal dimensional stability

    International Nuclear Information System (INIS)

    Kramer, Daniel P.; McNeil, Dennis C.; Ruhkamp, Joseph D.; Wells, Donna J.; Stringer, Robert L.; Howell, Edwin I.

    2002-01-01

    Maximizing the thermal to electrical conversion efficiency of a nuclear space power system requires that all of the available thermal energy be utilized in the most efficient manner. Microporous insulations are attractive for application in space power systems due to their very low thermal conductivity. Over the last few years, several new silica-based microporous insulating materials have become commercially available. Property comparisons of the various insulations obtained from company literature and experiments on microporous sample specimens are discussed. The results demonstrate that their machinability and thermal dimensional stability as a function of time at temperature and atmosphere are dependent on the particular material

  20. Assessment of commercially available pheromone lures for monitoring diamondback moth (Lepidoptera: Plutellidae) in canola.

    Science.gov (United States)

    Evenden, M L; Gries, R

    2010-06-01

    Sex pheromone monitoring lures from five different commercial sources were compared for their attractiveness to male diamondback moth, Plutella xylostella L. (Lepidoptera: Plutellidae) in canola, Brassica napus L., fields in western Canada. Lures that had the highest pheromone release rate, as determined by aeration analyses in the laboratory, were the least attractive in field tests. Lures from all the commercial sources tested released more (Z)-11-hexadecenal than (Z)-11-hexadecenyl acetate and the most attractive lures released a significantly higher aldehyde to acetate ratio than less attractive lures. Traps baited with sex pheromone lures from APTIV Inc. (Portland, OR) and ConTech Enterprises Inc. (Delta, BC, Canada) consistently captured more male diamondback moths than traps baited with lures from the other sources tested. In two different lure longevity field trapping experiments, older lures were more attractive to male diamondback moths than fresh lures. Pheromone release from aged lures was constant at very low release rates. The most attractive commercially available sex pheromone lures tested attracted fewer diamondback moth males than calling virgin female moths suggesting that research on the development of a more attractive synthetic sex pheromone lure is warranted.

  1. Simple method for the determination of rosiglitazone in human plasma using a commercially available internal standard.

    Science.gov (United States)

    Mamidi, Rao N V S; Benjamin, Biju; Ramesh, Mullangi; Srinivas, Nuggehally R

    2003-09-01

    To the best of our knowledge, bioanalytical methods to determine rosiglitazone in human plasma reported in literature use internal standards that are not commercially available. Our purpose was to develop a simple method for the determination of rosiglitazone in plasma employing a commercially available internal standard (IS). After the addition of celecoxib (IS), plasma (0.25 mL) samples were extracted into ethyl acetate. The residue after evaporation of the organic layer was dissolved in 750 microL of mobile phase and 50 microL was injected on to HPLC. The separation was achieved using a Hichrom KR 100, 250 x 4.6 mm C(18) with a mobile phase composition potassium dihydrogen phosphate buffer (0.01 m, pH 6.5):acetonitrile:methanol (40:50:10, v/v/v). The flow-rate of the mobile phase was set at 1 mL/min. The column eluate was monitored by fluorescence detector set at an excitation wavelength of 247 nm and emission wavelength of 367 nm. Linear relationships (r(2) > 0.99) were observed between the peak area ratio rosiglitazone to IS vs rosiglitazone concentrations across the concentration range 5-1000 ng/mL. The intra-run precision (%RSD) and accuracy (%Dev) in the measurement of rosiglitazone were 80% for both rosiglitazone and IS from human plasma. The lower limit of quantitation of the assay was 5 ng/mL. In summary, the methodology for rosiglitazone measurement in plasma was simple, sensitive and employed a commercially available IS. Copyright 2003 John Wiley & Sons, Ltd.

  2. Summary tables of six commercially available entry control and contraband detection technologies

    International Nuclear Information System (INIS)

    Hunter, John Anthony

    2005-01-01

    Existing contraband detection and entry control devices such as metal detectors, X-ray machines, and radiation monitors were investigated for their capability to operate in an automated environment. In addition, a limited number of new devices for detection of explosives, chemicals, and biological agents were investigated for their feasibility for inclusion in future physical security systems. The tables in this document resulted from this investigation, which was part of a conceptual design upgrade for the United States Mints. This summary of commercially available technologies was written to provide a reference for physical security upgrades at other sites

  3. Effect of commercially available egg cures on the survival of juvenile salmonids.

    Directory of Open Access Journals (Sweden)

    Shaun Clements

    Full Text Available There is some concern that incidental consumption of eggs cured with commercially available cures for the purpose of sport fishing causes mortality in juvenile salmon. We evaluated this by feeding juvenile spring Chinook (Oncorhynchus tshawytscha and steelhead (O. mykiss with eggs cured with one of five commercially available cures. We observed significant levels of mortality in both pre-smolts and smolts. Depending on the experiment, 2, 3, or 4 of the cures were associated with mortality. Mortality tended to be higher in the smolts than in the parr, but there was no clear species effect. The majority of mortality occurred within the first 10 d of feeding. Removal of sodium sulfite from the cure significantly reduced the level of mortality. Soaking the eggs prior to feeding did not reduce mortality. We observed a clear relationship between the amount of cured egg consumed each day and the survival time. We conclude that consumption of eggs cured with sodium sulfite has the potential to cause mortality in juvenile steelhead and Chinook salmon in the wild.

  4. Flavone glycosides from commercially available Lophatheri Herba and their chromatographic fingerprinting and quantitation

    Directory of Open Access Journals (Sweden)

    Jyun-Siang Fan

    2015-12-01

    Full Text Available Lophatheri Herba (Danzhuye; LH, the dried leaves of Lophatherum gracile Brongn (Poaceae, is commonly used in Chinese herbal medicine as an antipyretic, antibacterial, and diuretic. Chemical analysis has been conducted to isolate and identify seven major flavonoid glycosides, including a new flavone C-glycoside, luteolin 6-C-β-D-glucuronopyranosyl-(1→2-β-D-glucopyranoside (1, isoorientin (2, swertiajaponin (3, luteolin 6-C-β-D-glucuronopyranosyl-(1→2-α-L-arabinopyranoside (4, isovitexin (5, swertisin (6, luteolin 7-O-β-D-glucopyranoside (7, and luteolin 6-C-α-L-arabinopyranoside (8, from commercially available LHs in Taiwan. The structure of the new compound (1, the maximum component, was determined by extensive one- (1D- and two-dimensional (2D- nuclear magnetic resonance (NMR, and MS spectral analyses. The 1H and 13C-NMR of two rotameric pairs of 3 and 6 were also assigned. To establish the quality control platform of LH, we developed a simultaneous determination of multiple components in 10 commercially available LHs, collected from different areas of Taiwan, by high performance liquid chromatography (HPLC and ultra performance liquid chromatography (UPLC, as well as quantitative measurement of the major components 1–4, and 8. All isolated major compounds showed good linear regression (R2 ≥ 0.9993 within the test ranges and high reproducibility. These methods are readily accessible for the quality control of LH.

  5. Packaging related properties of commercially available biopolymers – An overview of the status quo

    Directory of Open Access Journals (Sweden)

    V. Jost

    2018-05-01

    Full Text Available Several commercially available thermoplastic biopolymers were processed in a continuous extrusion line. The molecular weight, crystallinity, and mechanical and permeation properties of the cast films were determined in order to evaluate the status quo of biopolymers currently commercially available. The biopolymers that were evaluated were polylactic acid (PLA, several polyhydroxyalkanoates (PHAs (Poly(3-hydroxybutyrate (PHB, poly(3-hydroxybutyrate-co-4-hydroxybutyrate (PHBHB, poly(3-hydroxybutyrate-co-3-hydroxyvalerate (PHBV, thermoplastic starch (TPS, polybutylene adipate terephthalate (PBAT, polybutylene succinate (PBS, polycaprolactone (PCL and biobased polyethylene (BioPE. Due to its potential for biobased production, thermoplastic polyurethane elastomer (TPU was also analysed. Mechanical analysis showed the PLA and PHA films had high strength and extremely low elongation at break. These were also the materials with the highest molecular weights. Films made of TPU, PCL, TPS, PBAT and BioPE had a significantly lower Young’s modulus and significantly higher elongation at break; these films had comparatively low molecular weights. Permeation measurements showed that PHA films, and particularly PHBV, had the lowest oxygen and water vapour permeability of the biopolymers that were analysed. The biopolymers BioPE, TPS, PCL, TPU and PBAT were highly permeable to oxygen, and had comparatively low molecular weight. The biopolymers TPU, PBS, PBAT, PCL and TPS were highly permeable to water vapour.

  6. Measuring the chemical and cytotoxic variability of commercially available kava (Piper methysticum G. Forster.

    Directory of Open Access Journals (Sweden)

    Amanda C Martin

    Full Text Available Formerly used world-wide as a popular botanical medicine to reduce anxiety, reports of hepatotoxicity linked to consuming kava extracts in the late 1990s have resulted in global restrictions on kava use and have hindered kava-related research. Despite its presence on the United States Food and Drug Administration consumer advisory list for the past decade, export data from kava producing countries implies that US kava imports, which are not publicly reported, are both increasing and of a fairly high volume. We have measured the variability in extract chemical composition and cytotoxicity towards human lung adenocarcinoma A549 cancer cells of 25 commercially available kava products. Results reveal a high level of variation in chemical content and cytotoxicity of currently available kava products. As public interest and use of kava products continues to increase in the United States, efforts to characterize products and expedite research of this potentially useful botanical medicine are necessary.

  7. Review of Commercially Available Microfluidic Materials and Fabricating Techniques for Point of Care Testing

    Directory of Open Access Journals (Sweden)

    Luck EREKU

    2016-07-01

    Full Text Available During the last two decades silicon and MEMs technology had been the mainstay of early microfluidic devices. However, recent times have brought into focus the need for low cost and readily available materials capable of achieving the expected microfluidics physical and chemical requirements. Also what mentioning is the rapid improvement in microfabrication technology over the years, which has significantly aided new and cheaper ways to produce microfluidic Point-Of-Care-Testing devices commercially or for research purposes. This review article discusses the usefulness of a wide range of available materials and their unique properties suitability in microfluidic applications. Likewise, advantages and drawbacks of manufacturing procedures and outputs of different fabrication methods are also brought into focus.

  8. 78 FR 65700 - Notice of Availability of the Utah Greater Sage-Grouse Draft Land Use Plan Amendments and...

    Science.gov (United States)

    2013-11-01

    .../Garfield/Antimony, Pinyon, Warm Springs, House Range, Pony Express, Box Elder, Randolph, Park City, and...) Pinyon Management Framework Plan (MFP) (1978) Warm Springs RMP (1987) House Range RMP (1987) Pony Express... lands identified as having the highest value to maintaining sustainable Greater Sage-Grouse populations...

  9. Dose Calculation Accuracy of the Monte Carlo Algorithm for CyberKnife Compared with Other Commercially Available Dose Calculation Algorithms

    International Nuclear Information System (INIS)

    Sharma, Subhash; Ott, Joseph; Williams, Jamone; Dickow, Danny

    2011-01-01

    Monte Carlo dose calculation algorithms have the potential for greater accuracy than traditional model-based algorithms. This enhanced accuracy is particularly evident in regions of lateral scatter disequilibrium, which can develop during treatments incorporating small field sizes and low-density tissue. A heterogeneous slab phantom was used to evaluate the accuracy of several commercially available dose calculation algorithms, including Monte Carlo dose calculation for CyberKnife, Analytical Anisotropic Algorithm and Pencil Beam convolution for the Eclipse planning system, and convolution-superposition for the Xio planning system. The phantom accommodated slabs of varying density; comparisons between planned and measured dose distributions were accomplished with radiochromic film. The Monte Carlo algorithm provided the most accurate comparison between planned and measured dose distributions. In each phantom irradiation, the Monte Carlo predictions resulted in gamma analysis comparisons >97%, using acceptance criteria of 3% dose and 3-mm distance to agreement. In general, the gamma analysis comparisons for the other algorithms were <95%. The Monte Carlo dose calculation algorithm for CyberKnife provides more accurate dose distribution calculations in regions of lateral electron disequilibrium than commercially available model-based algorithms. This is primarily because of the ability of Monte Carlo algorithms to implicitly account for tissue heterogeneities, density scaling functions; and/or effective depth correction factors are not required.

  10. Characteristics of canine platelet-rich plasma prepared with five commercially available systems.

    Science.gov (United States)

    Franklin, Samuel P; Garner, Bridget C; Cook, James L

    2015-09-01

    To characterize platelet-rich plasma (PRP) products obtained from canine blood by use of a variety of commercially available devices. Blood samples from 15 dogs between 18 months and 9 years of age with no concurrent disease, except for osteoarthritis in some dogs. PRP products were produced from blood obtained from each of the 15 dogs by use of each of 5 commercially available PRP-concentrating systems. Complete blood counts were performed on each whole blood sample and PRP product. The degree of platelet, leukocyte, and erythrocyte concentration or reduction for PRP, compared with results for the whole blood sample, was quantified for each dog and summarized for each concentrating system. The various PRP-concentrating systems differed substantially in the amount of blood processed, method of PRP preparation, amount of PRP produced, and platelet, leukocyte, and erythrocyte concentrations or reductions for PRP relative to results for whole blood. The characteristics of PRP products differed considerably. Investigators evaluating the efficacy of PRPs need to specify the characteristics of the product they are assessing. Clinicians should be aware of the data (or lack of data) supporting use of a particular PRP for a specific medical condition.

  11. Arduino Uno Microcontroller with Commercially Available Sensors Towards Generating Student Accessible Raw Meteorological Data

    Science.gov (United States)

    Henson, Gabrielle; Tanner, Meghan; Senevirathne, Indrajith

    Microcontroller systems can be a boon to cost - effective techniques that can be used to enhance teaching at college level. We have used Arduino microcontroller coupled with commercially available sensors to systematically measure, record and analyze temperature, humidity and barometric pressure and to upload the real time raw data to cloud. Corresponding data will be available in classroom settings for predictions, analysis and simple weather forecasting. Setup was assembled via breadboard, wire and simple soldering with an Arduino Uno ATmega328P microcontroller connected to a PC. The microcontroller was programmed with Arduino Software while the bootloader was used to upload the code. Commercial DHT22 humidity and temperature sensor and BMP180 barometric pressure sensor were used to obtain relative humidity, temperature and the barometric pressure. System was mounted inside a weather resistant enclosure and data measurements were obtained and were uploaded onto the PC and then to cloud. Cloud data can be accessed via a shared link in a General Education class for multitude of purposes.

  12. Microbiological quality assessment of commercially available medicinal plants in Peshawar city, Pakistan

    International Nuclear Information System (INIS)

    Khattak, K.F.

    2012-01-01

    Medicinal plants naturally harbor a variety of microorganisms. Besides, representing a direct health hazard to the consumer, these contaminated materials can cause the spoilage of pharmaceuticals and traditional preparations to which they are added. Assessment of microbiological loads of plants to assure safety and quality is therefore worth investigation. In the present study, 45 commercially available medicinal plants were evaluated for aerobic bacteria, fungi, coliforms, E. coli and Salmonella. All investigations were carried out in triplicate using standard methods. The results of the study revealed very high microbial loads and the presence of pathogenic bacteria in the plant samples. The aerobic bacterial count ranged from 1.3 x 102 to 5.6 x 10/sup 9/ cfu/g. The highest load was detected in the rhizomes of Curcuma longa. The coliform counts varied from 1.5 x 10/sup 2/ to 1.6 x 10/sup 4/ cfu/g. Among the selected herbs, 23 showed the presence of E. coli, while Salmonella spp. was detected in 13 samples. The fungal counts were above the international permissible level in the tested samples. It was concluded that commercially available plants may be high-risk substances and therefore quality of the plants may be regularly checked to ensure safety and make them fit for human consumption. (author)

  13. In vitro physical, chemical, and biological evaluation of commercially available metal orthodontic brackets.

    Science.gov (United States)

    Kim, Joo Hyoung; Cha, Jung Yul; Hwang, Chung Ju

    2012-12-01

    This in vitro study was undertaken to evaluate the physical, chemical, and biological properties of commercially available metal orthodontic brackets in South Korea, because national standards for these products are lacking. FOUR BRACKET BRANDS WERE TESTED FOR DIMENSIONAL ACCURACY, (MANUFACTURING ERRORS IN ANGULATION AND TORQUE), CYTOTOXICITY, COMPOSITION, ELUTION, AND CORROSION: Archist (Daeseung Medical), Victory (3M Unitek), Kosaka (Tomy), and Confidence (Shinye Odontology Materials). The tested rackets showed no significant differences in manufacturing errors in angulation, but Confidence brackets showed a significant difference in manufacturing errors in torque. None of the brackets were cytotoxic to mouse fibroblasts. The metal ion components did not show a regular increasing or decreasing trend of elution over time, but the volume of the total eluted metal ions increased: Archist brackets had the maximal Cr elution and Confidence brackets appeared to have the largest volume of total eluted metal ions because of excessive Ni elution. Confidence brackets showed the lowest corrosion resistance during potentiodynamic polarization. The results of this study could potentially be applied in establishing national standards for metal orthodontic brackets and in evaluating commercially available products.

  14. Effect of commercially available egg cures on the survival of juvenile salmonids

    Science.gov (United States)

    Clements, S.; Chitwood, R.; Schreck, C.B.

    2011-01-01

    There is some concern that incidental consumption of eggs cured with commercially available cures for the purpose of sport fishing causes mortality in juvenile salmon. We evaluated this by feeding juvenile spring Chinook (Oncorhynchus tshawytscha) and steelhead (O. mykiss) with eggs cured with one of five commercially available cures. We observed significant levels of mortality in both pre-smolts and smolts. Depending on the experiment, 2, 3, or 4 of the cures were associated with mortality. Mortality tended to be higher in the smolts than in the parr, but there was no clear species effect. The majority of mortality occurred within the first 10 d of feeding. Removal of sodium sulfite from the cure significantly reduced the level of mortality. Soaking the eggs prior to feeding did not reduce mortality. We observed a clear relationship between the amount of cured egg consumed each day and the survival time. We conclude that consumption of eggs cured with sodium sulfite has the potential to cause mortality in juvenile steelhead and Chinook salmon in the wild.

  15. Evaluation of the physico-chemical, rheological and sensory characteristics of commercially available Frankfurters in Spain and consumer preferences.

    Science.gov (United States)

    González-Viñas, M A; Caballero, A B; Gallego, I; García Ruiz, A

    2004-08-01

    The physico-chemical, rheological and sensory characteristics of different commercially available Frankfurters were studied. Samples presented values of A(w) and pH from 0.954 to 0.972 and 5.88 to 6.43, respectively. Greater differences were observed in parameters such as fat and salt content, with values ranging from 10.83% to 21.92% and 1.85% to 3.01%, respectively. With regard to total nitrogen, all samples presented values close to 2%. Free-choice profiling and generalised procrustes analysis of the sensory data permitted differentiation between samples and provided information about the attributes responsible for the observed differences. All the frankfurters scored in the moderate range for overall acceptability. Consumers identified reasons for purchasing frankfurters when evaluating the product's packaging. The most important criterion for consumers when purchasing frankfurters was the appetising aspect of the product in the packaging's illustration.

  16. Catalog of Realizations for DXCCII using Commercially Available ICs and Applications

    Directory of Open Access Journals (Sweden)

    S. Maheshwari

    2012-04-01

    Full Text Available This paper presents fifteen distinct practical realizations for dual-X second generation current conveyor (DXCCII using commercially available integrated circuits. Detailed comparisons and results are presented to verify the utility of proposed realizations. The catalog of proposed realizations is a first attempt and is expected to be useful for testing newly developed circuits based on dual-X second generation current conveyor. Each of the first fourteen proposed realizations uses four ICs. One three IC based implementation is further given making the total count fifteen. Some additional features are also explored which further enhance the versatility of DXCCII. The paper further presents a novel and compact quadrature oscillator to verify the applicability of the proposed realizations. Single resistance control of the frequency of oscillation is also demonstrated by employing the new gain-variable DXCCII. Experimental results are also included along with simulation results to validate the proposed theory and its practical significance.

  17. Comparative evaluation of enamel abrasivity of different commercially available dentifrices – An In vitro Study

    Directory of Open Access Journals (Sweden)

    Rupali Athawale

    2018-01-01

    Full Text Available Background: Toothbrushing with toothpaste is a major contributor to dental abrasion. A number of factors such as abrasivity and concentration of the toothpaste, brushing frequency, brushing duration, force of brushing, and toothbrush bristle stiffness have a potential impact on the abrasion process of dental hard tissue. However, the abrasivity of the toothpaste is the most important parameter that affects the abrasion process of dental hard tissue. Aims: This study aims to evaluate the maximum and mean enamel abrasivity of commercially available dentifrices such as Colgate total®, Pepsodent whitening®, Vicco vajradanti®, Dabur red® in primary and permanent teeth. Materials and Methods: Human extracted 60 primary and 60 permanent teeth were randomly selected based on the inclusion criteria. Teeth were sectioned at cementoenamel junction using diamond disc and mounted in an acrylic resin blocks. Baseline profilometric measurements were recorded for all the samples. Four commonly used dentifrices were selected and labeled as Group A (Colgate Total®, B (Pepsodent Whitening®, C (Vicco Vajradanti®, and D (Dabur Red®. Toothpaste slurry was prepared. Tooth specimens were brushed in vitro using a customized brushing machine. After toothbrushing, profilometric measurements were obtained, and the differences in readings served as proxy measure to assess surface abrasion. Data were collected and analyzed using student t-test and ANOVA test. Student t-test was used to compare the enamel abrasivity prebrushing and postbrushing, and ANOVA was used to compare the enamel abrasivity among the four different commercially available toothpastes. Results: In permanent teeth, all the toothpastes were found to cause significant enamel abrasion (P = 0.000 and a significant variation was observed when maximum (P = 0.008 and mean (P = 0.036 enamel abrasivity of these toothpastes were compared. In primary teeth also, all the toothpastes caused significant abrasion

  18. Complete nutrient content of four species of commercially available feeder insects fed enhanced diets during growth.

    Science.gov (United States)

    Finke, Mark D

    2015-11-01

    Commercially raised feeder insects used to feed captive insectivores are a good source of many nutrients but are deficient in several key nutrients. Current methods used to supplement insects include dusting and gut-loading. Here, we report on the nutrient composition of four species of commercially raised feeder insects fed a special diet to enhance their nutrient content. Crickets, mealworms, superworms, and waxworms were analyzed for moisture, crude protein, fat, ash, acid detergent fiber, total dietary fiber, minerals, amino acids, fatty acids, vitamins, taurine, carotenoids, inositol, and cholesterol. All four species contained enhanced levels of vitamin E and omega 3 fatty acids when compared to previously published data for these species. Crickets, superworms, and mealworms contained β-carotene although using standard conversion factors only crickets and superworms would likely contain sufficient vitamin A activity for most species of insectivores. Waxworms did not contain any detectable β-carotene but did contain zeaxanthin which they likely converted from dietary β-carotene. All four species contained significant amounts of both inositol and cholesterol. Like previous reports all insects were a poor source of calcium and only superworms contained vitamin D above the limit of detection. When compared to the nutrient requirements as established by the NRC for growing rats or poultry, these species were good sources of most other nutrients although the high fat and low moisture content of both waxworms and superworms means when corrected for energy density these two species were deficient in more nutrients than crickets or mealworms. These data show the value of modifying the diet of commercially available insects as they are growing to enhance their nutrient content. They also suggest that for most insectivores properly supplemented lower fat insects such as crickets, or smaller mealworms should form the bulk of the diet. © 2015 The Authors. Zoo Biology

  19. Intervariability and intravariability of bone morphogenetic proteins in commercially available demineralized bone matrix products.

    Science.gov (United States)

    Bae, Hyun W; Zhao, Li; Kanim, Linda E A; Wong, Pamela; Delamarter, Rick B; Dawson, Edgar G

    2006-05-20

    Enzyme-linked immunosorbent assay was used to detect bone morphogenetic proteins (BMPs) 2, 4, and 7 in 9 commercially available ("off the shelf") demineralized bone matrix (DBM) product formulations using 3 different manufacturer's production lots of each DBM formulation. To evaluate and compare the quantity of BMPs among several different DBM formulations (inter-product variability), as well as examine the variability of these proteins in different production lots within the same DBM formulation (intra-product variability). DBMs are commonly used to augment available bone graft in spinal fusion procedures. Surgeons are presented with an ever-increasing variety of commercially available human DBMs from which to choose. Yet, there is limited information on a specific DBM product's osteoinductive efficacy, potency, and constancy. There were protein extracts from each DBM sample separately dialyzed 4 times against distilled water at 4 degrees C for 48 hours. The amount of BMP-2, BMP-4, and BMP-7 was determined using enzyme-linked immunosorbent assay. RESULTS.: The concentrations of detected BMP-2 and BMP-7 were low for all DBM formulations, only nanograms of BMP were extracted from each gram of DBM (20.2-120.6 ng BMP-2/g DBM product; 54.2-226.8 ng BMP-7/g DBM). The variability of BMP concentrations among different lots of the same DBM formulation, intra-product variability, was higher than the variability of concentrations among different DBM formulations, inter-product variability (coefficient of variation range BMP-2 [16.34% to 76.01%], P DBMs are low, in the order of 1 x 10(-9) g of BMP/g of DBM. There is higher variability in concentration of BMPs among 3 different lots of the same DBM formulation than among different DBM formulations. This variability questions DBM products' reliability and, possibly, efficacy in providing consistent osteoinduction.

  20. Estimation of the antioxidant activity of the commercially available fermented milks.

    Science.gov (United States)

    Najgebauer-Lejko, Dorota; Sady, Marek

    2015-01-01

    Free radicals are connected with the increased risk of certain diseases, especially cancers. There is some scientific evidence that antioxidant-rich diet may inhibit the negative impact of free radicals. The aim of the present study was to analyse the antioxidant capacity of the selected commercial natural and flavoured fermented milks offered in Poland, derived from different producers. The following commercially available natural fermented milks: 12 yoghurts, 12 kefirs, 2 butter milks, 2 cultured milks, Turkish yoghurt drink (ayran) and the following flavoured fermented milks: 22 yoghurts, 2 acidophillus milks, 2 kefirs, butter milk and vegetable flavoured fermented milk were analysed for their antioxidant potential. The antioxidant capacity was assessed, in two replicates and twice for each product, by means of ferric reducing antioxidant power (FRAP) and DPPH radical scavenging ability (expressed as ARP - anti radical power) methods. Among all analysed plain products, yoghurts and kefirs were characterised by the highest antioxidant activity. The presence of probiotic Lactobacillus casei strains in the product positively affected both FRAP and ARP values. Antioxidant capacity of the flavoured fermented milks was primarily affected by the type and quality (e.g. fruit concentration) of the added flavouring preparation. The most valuable regarding the estimated parameters were chocolate, coffee, grapefruit with green tea extract as well as bilberry, forest fruits, strawberry and cherry with blackcurrant fillings. Protein content, inclusion of probiotic microflora as well as type and quality of flavouring preparations are the main factors affecting antioxidant properties of fermented milks.

  1. Dissolution of Enamel on Exposure to Various Commercial Beverages Available in India.

    Science.gov (United States)

    Panda, Abikshyeet; Ghosh, Bikramaditya; Pal, Imon; Kumar, Vijay; Bhuyan, Lipsa; Dash, Kailash C

    2017-11-01

    The study was aimed to estimate the pH of the commonly available soft drinks in the Indian market and to assess the detrimental effects of the juices and beverages on the tooth surface by measuring the weight loss of the tooth sample. The study was done with eight different types of commercially available carbonated drink and fruit juices available in the Indian market among which six were carbonated drinks and two were juices. Carbonated drinks experimented were Coca-Cola, Pepsi, Fanta, Mirinda, 7Up and Sprite, and two fruit juices were Tropicana orange juice and real orange juice. Ten different bottles from each category were obtained, and the pH was estimated. Each of the beverages was divided into batch of 10 containers containing the tooth sample. Weight of all samples was measured at 24, 48, 72, 96, and 120 hours with subsequently changing each solution at an interval of 24 hours. The mean pH of the beverages was found ranging from 2.13 ± 0.02 in Pepsi to 3.41 ± 0.02 in Tropicana on opening. The mean pH of water was found to be 6.98 ± 0.01. Among carbonated drinks, the mean weight loss after 24 hours was highest in Coca-Cola and least in 7Up. Tropicana fruit juice had a higher tooth loss than real orange juices. When compared with water, the tooth loss was significantly higher in Coca-Cola after all specified time (hours). The pH of both carbonated drinks and fruit juices was below the critical pH. The weight loss was also seen after every 24 hours in all the carbonated drinks and beverages. The study showed that these commercial beverages are harmful to the tooth structures, and hence, the health professionals play a major role in educating the population about its effects and advising them to use these products precisely. The change in lifestyle has increased the demand of soft drinks and artificial juice in Indian market. The use of these carbonated drinks and fruit juices causes damage to the tooth structure in all ages, especially in young mass. Our

  2. Post-Vacuum-Assisted Stereotactic Core Biopsy Clip Displacement: A Comparison Between Commercially Available Clips and Surgical Clip.

    Science.gov (United States)

    Yen, Peggy; Dumas, Sandra; Albert, Arianne; Gordon, Paula

    2018-02-01

    The placement of localization clips following percutaneous biopsy is a standard practice for a variety of situations. Subsequent clip displacement creates challenges for imaging surveillance and surgical planning, and may cause confusion amongst radiologists and between surgeons and radiologists. Many causes have been attributed for this phenomenon including the commonly accepted "accordion effect." Herein, we investigate the performance of a low cost surgical clip system against 4 commercially available clips. We retrospectively reviewed 2112 patients who underwent stereotactic vacuum-assisted core biopsy followed by clip placement between January 2013 and June 2016. The primary performance parameter compared was displacement >10 mm following vacuum-assisted stereotactic core biopsy. Within the group of clips that had displaced, the magnitude of displacement was compared. There was a significant difference in displacement among the clip types (P < .0001) with significant pairwise comparisons between pediatric surgical clips and SecureMark (38% vs 28%; P = .001) and SenoMark (38% vs 27%; P = .0001) in the proportion displaced. The surgical clips showed a significant magnitude of displacement of approximately 25% greater average distance displaced. As a whole, the commercial clips performed better than the surgical clip after stereotactic vacuum-assisted core biopsy suggesting the surrounding outer component acts to anchor the central clip and minimizes clip displacement. The same should apply to tomosynthesis-guided biopsy. Crown Copyright © 2017. Published by Elsevier Inc. All rights reserved.

  3. Radioimmunoassay of human homologous prolactin in serum with commercially available reagents. [/sup 125/I tracer technique

    Energy Technology Data Exchange (ETDEWEB)

    Kao, P.C.; Jiang, N.S.; Abboud, C.F.

    1977-09-01

    A clinically useful and reproducible radioimmunoassay for human homologous prolactin, established with commercially available reagents, was studied and validated. We present detailed conditions for iodination and purification of labeled prolactin and the optimal conditions for the assay. By the method, we found values (..mu..g/liter) as follows for serum prolactin: normal men, 8.9 +- 5.2 (mean +- SD); normal women, 11.8 +- 5.5; normal women taking contraceptive pills, 9.2 +- 5.0; pregnant women in the third trimester, 188 +- 69.5; patients with various diseases other than of the hypothalamic-pituitary axis, 9.3 +- 6.3; in some patients with amenorrhea and galactorrhea of diverse origin, 78.2 +- 87.4; and in some patients with surgically proven pituitary tumor, 1414 +- 1980. Results under provocative testing are also presented for a patient with normal hypothalamic-pituitary function.

  4. Extensive EIS characterization of commercially available lithium polymer battery cell for performance modelling

    DEFF Research Database (Denmark)

    Stanciu, Tiberiu; Stroe, Daniel Loan; Teodorescu, Remus

    2015-01-01

    or degradation of an electrochemical system. Used for Lithium-ion (Li-ion) batteries, this method allows for a fast and accurate assessment of the battery's impedance at any working point, without modifying the state of the battery. The influence of the operating conditions, state of charge (SOC) and temperature...... on the performance of a commercially available 53 Ah Lithium polymer battery cell, manufactured by Kokam Co. Ltd., is investigated in laboratory experiments, at its beginning of life, by means of EIS. A data fitting algorithm was used to obtain the parameter values for the proposed equivalent electrical circuit......, which was further selected for the development of an accurate EIS based performance model for the chosen Li-ion battery cell....

  5. Comparative studies of commercially available T4-RIA-kits. Pt. 2

    International Nuclear Information System (INIS)

    Schmidt, H.A.E.; Lipke, P.

    1978-01-01

    The investigation of the tested commercially available T 4 -RIA-Kits have shown that: The separation of hypo-, eu- and hyperthyroid values is better with kits a) and f) than with b), c), d) and e), though all kits give acceptable values under routine operating conditions, kit b) takes less time and work than the other tested kits, depending on the kit used, the time needed for 100 determinations varies between 1,5 and 4 hr. A general recommendation for one of the tested T 4 -RIA-Kits cannot be made since the choice of a kit depends not only on the criteria discussed but also on local circumstances. (orig.) [de

  6. Detection and quantification of serum or plasma HCV RNA: mini review of commercially available assays.

    Science.gov (United States)

    Le Guillou-Guillemette, Helene; Lunel-Fabiani, Francoise

    2009-01-01

    The treatment schedule (combination of compounds, doses, and duration) and the virological follow-up for management of antiviral treatment in patients chronically infected by HCV is now well standardized, but to ensure good monitoring of the treated patients, physicians need rapid, reproducible, and sensitive molecular virological tools with a wide range of detection and quantification of HCV RNA in blood samples. Several assays for detection and/or quantification of HCV RNA are currently commercially available. Here, all these assays are detailed, and a brief description of each step of the assay is provided. They are divided into two categories by method: those based on signal amplification and those based on target amplification. These two categories are then divided into qualitative, quantitative, and quantitative detection assays. The real-time reverse-transcription polymerase chain reaction (RT-PCR)-based assays are the most promising strategy in the HCV virological area.

  7. microRNA biosensors: Opportunities and challenges among conventional and commercially available techniques.

    Science.gov (United States)

    Kilic, Tugba; Erdem, Arzum; Ozsoz, Mehmet; Carrara, Sandro

    2018-01-15

    As being the most extensively studied, non-coding, evolutionary conserved, post-transcriptional gene regulators of genome, microRNAs (miRNAs) have taken great attention among various disciplines due to their important roles in biological processes and link with cancer. Due to their diagnostic value, there have been many conventional methods used in detection of miRNAs including northern blotting, quantitative real time PCR (qRT-PCR) and microarray technology besides novel techniques based on various nanotechnology approaches and molecular biology tools including miRNA biosensors. The aim of this review is to explain the importance of miRNAs in biomedical field with an emphasis on early cancer diagnosis by overviewing both research based and commercially available miRNA detection methods in the last decade considering their strengths and weakness with an emphasis on miRNA biosensors. Copyright © 2017 Elsevier B.V. All rights reserved.

  8. Measurement of some radiologically and nutritionally important trace elements in human milk and commercially available milk

    International Nuclear Information System (INIS)

    Nair, Suma; Sathyapriya, R.S.; Nair, M.G.; Ravi, Prabhat; Bhati, Sharda

    2011-01-01

    Milk is considered to be a complete food and an almost indispensable part of the diets of infants and children. In this paper we present the concentration of some radiologically and nutritionally important trace elements such as Th, Cs, Co, Rb, Fe, Ca and Zn present in human milk and commercially available milk. The trace elements in human and other milk samples were determined using instrumental neutron activation analysis technique. The results show that higher concentrations of Th, Cs, Ca and Rb were found in ordinary milk samples in comparison with the human milk samples. Whereas, a higher concentrations of Fe and Co were observed in human milk samples. These data will be useful for the nutritional and biokinetic studies of these elements in infants and children of different age groups. (author)

  9. Microbiological Contamination of Ice Cream Commercially Available in Korea and its Irradiation Effect

    International Nuclear Information System (INIS)

    Yook, H.S.; Kim, H.J.; Jo, C.U.; Kim, D.S.; Byun, M.W.

    2005-01-01

    The microbial contamination of ice cream product commercially available in Korea was determined using ice bar, ice cream, ice milk and non-milk fat ice cream. Irradiation effect on enhancement of microbiological safety was also investigated at doses of 1, 3, and 5 kGy. In all products, yeast and molds were not detected, however, total aerobic and coliform bacteria were detected at 1~2 and 1~1.5 Log CFU/g level, respectively. According to the different flavor used in ice cream, total aerobic bacteria were detected as 2.30, 2.90, and 3.32 Log CFU/g level in vanilla, chocolate, and strawberry ice cream, respectively. Yeast and mold was not detected in vanilla ice cream but 2.30 and 2.70 Log CFU/g in chocolate and strawberry ice cream, respectively

  10. Development of a reader for track etch detectors based on a commercially available slide scanner

    CERN Document Server

    Steele, J D; Tanner, R J; Bartlett, D T

    1999-01-01

    NRPB has operated a routine neutron personal dosimetry service based on the electrochemical etch of PADC elements since 1986. Since its inception it has used an automated reader based on a video camera and real time analysis. A new and more powerful replacement system has been developed using a commercially available photographic slide scanner. This permits a complete image of the dosemeter to be grabbed in a single scan, generating a 2592x3888 pixel file which is saved for subsequent analysis. This gives an effective pixel size of 10x10 mu m with an image of the entire dosemeter in one field of view. Custom written software subsequently analyses the image to assess the number of etched pits on the dosemeter and read the detector identification number (code). Batch scanning of up to 40 detectors is also possible using an autofeed attachment. The system can be used for electrochemically etched tracks for neutron detectors and chemically etched tracks for radon detectors.

  11. Clinical experience with a commercially available negative oral contrast medium in PET/CT

    Energy Technology Data Exchange (ETDEWEB)

    Hausegger, K.; Reinprecht, P. [Roentgendiagnostisches Zentralinstitut, LKH Klagenfurt (Austria); Kau, T. [Roentgendiagnostisches Zentral Inst., Klagenfurt (Austria); Igerc, I.; Lind, P. [Abt. fuer Nuklearmedizin und Spezielle Endokrinologie, LKH Klagenfurt (Austria)

    2005-06-01

    Purpose: to evaluate a commercially available negative oral contrast material for PET/CT. Material and methods: in a prospective series of 49 patients, Mukofalk {sup registered}, which is a vegetarian-based substance, was used as a negative oral contrast medium in whole body PET/CT studies. Mukofalk was administered during a time period of 1.5 hours before the examination. Quality of small bowl distension and eventual pathological tracer uptake in the intestine were evaluated. Results: distension of the small bowel was excellent or good in 41 (85%) and poor in 8 (15%) patients. Mild tracer uptake in the small bowel was observed in 5 patients (10.2%) and moderate uptake in another 2 patients (4%). In none of these patients did the F-18 FDG uptake interfere with image interpretation. Conclusion: Mukofalk {sup registered} can be used as a negative oral contrast medium in PET/CT studies. (orig.)

  12. Measuring large aspherics using a commercially available 3D-coordinate measuring machine

    Science.gov (United States)

    Otto, Wolfgang; Matthes, Axel; Schiehle, Heinz

    2000-07-01

    A CNC-controlled precision measuring machine is a very powerful tool in the optical shop not only to determine the surface figure, but also to qualify the radius of curvature and conic constant of aspherics. We used a commercially available 3D-coordinate measuring machine (CMM, ZEISS UPMC 850 CARAT S-ACC) to measure the shape of the GEMINI 1-m convex secondary mirrors at different lapping and polishing stages. To determine the measuring accuracy we compared the mechanical measurements with the results achieved by means of an interferometrical test setup. The data obtained in an early stage of polishing were evaluated in Zernike polynomials which show a very good agreement. The deviation concerning long wave rotational symmetrical errors was 20 nm rms, whereas the accuracy measuring of mid spatial frequency deviations was limited to about 100 nm rms.

  13. Radioimmunoassay of human homologous prolactin in serum with commercially available reagents

    International Nuclear Information System (INIS)

    Kao, P.C.; Jiang, N.S.; Abboud, C.F.

    1977-01-01

    A clinically useful and reproducible radioimmunoassay for human homologous prolactin, established with commercially available reagents, was studied and validated. We present detailed conditions for iodination and purification of labeled prolactin and the optimal conditions for the assay. By the method, we found values (μg/liter) as follows for serum prolactin: normal men, 8.9 +- 5.2 (mean +- SD); normal women, 11.8 +- 5.5; normal women taking contraceptive pills, 9.2 +- 5.0; pregnant women in the third trimester, 188 +- 69.5; patients with various diseases other than of the hypothalamic-pituitary axis, 9.3 +- 6.3; in some patients with amenorrhea and galactorrhea of diverse origin, 78.2 +- 87.4; and in some patients with surgically proven pituitary tumor, 1414 +- 1980. Results under provocative testing are also presented for a patient with normal hypothalamic-pituitary function

  14. Clinical experience with a commercially available negative oral contrast medium in PET/CT

    International Nuclear Information System (INIS)

    Hausegger, K.; Reinprecht, P.; Kau, T.; Igerc, I.; Lind, P.

    2005-01-01

    Purpose: to evaluate a commercially available negative oral contrast material for PET/CT. Material and methods: in a prospective series of 49 patients, Mukofalk registered , which is a vegetarian-based substance, was used as a negative oral contrast medium in whole body PET/CT studies. Mukofalk was administered during a time period of 1.5 hours before the examination. Quality of small bowl distension and eventual pathological tracer uptake in the intestine were evaluated. Results: distension of the small bowel was excellent or good in 41 (85%) and poor in 8 (15%) patients. Mild tracer uptake in the small bowel was observed in 5 patients (10.2%) and moderate uptake in another 2 patients (4%). In none of these patients did the F-18 FDG uptake interfere with image interpretation. Conclusion: Mukofalk registered can be used as a negative oral contrast medium in PET/CT studies. (orig.)

  15. Influence of the availability of commercial infant foods on feeding practices in Jamaica.

    Science.gov (United States)

    De Morales, A; Larkin, F A

    1972-03-01

    A study was conducted into infant feeding regimens among 150 Jamaican women. The target population was limited to women living in the Kingston-St. Andrews Corporate area and attending hospitals or clinics where nutrition education was offered. Subjects were questioned as to obstetric history, socio-economic status, sources of information, and infant feeding habits. Nearly all infants in the study were weaned by 1 year of age with a nearly equal number being weaned in the 1st 6 months and the 2nd 6 months. Mothers who never breast fed their infants or weaned early did so for unavoidable reasons, e.g., maternal illness, infant prematurity or hospitalization, or insufficient milk. Most weaning due to these reasons occurred within the 1st 6 months of life. More than 1/2 of the women did not have clearly defined physiological reasons for discontinuing breast feeding. Income and place of residence were not related to the decision to cease breast feeding. Women attending private clinics and receiving information on infant nutrition from health personnel tended to breast feed for a longer time. 18 commercial infant food products were available. 15 of these were a form of processed cow's milk requiring a measure of skill in preparing. The rest were goat's milk, cow's milk, or gruel. 40% of the women in the study used more than 1 of these commercial preparations, indicating a general preference for formulas rather than for a particular brand name. There is a question as to whether the wide availability of these products actually influenced women's decisions to discontinue breast feeding.

  16. Dose measurements in pulsed radiation fields with commercially available measuring components

    International Nuclear Information System (INIS)

    Friedrich, Sabrina; Hupe, Oliver

    2016-01-01

    Dose measurements in pulsed radiation fields with dosemeters using the counting technique are known to be inappropriate. Therefore, there is a demand for a portable device able to measure the dose in pulsed radiation fields. As a detector, ionisation chambers seem to be a good alternative. In particular, using a secondary standard ionisation chamber in combination with a reliable charge-measuring system would be a good solution. The Physikalisch-Technische Bundesanstalt (PTB) uses secondary standard ionisation chambers in combination with PTB-made measuring electronics for dose measurements at its reference fields. However, for general use, this equipment is too complex. For measurements on-site, a mobile special electronic system [Hupe, O. and Ankerhold, U. Determination of ambient and personal dose equivalent for personnel and cargo security screening. Radiat. Prot. Dosim. 121(4), 429-437 (2006)] has been used successfully. Still, for general use, there is a need for a much simpler but a just as good solution. A measuring instrument with very good energy dependence for H*(10) is the secondary standard ionisation chamber HS01. An easy-to-use and commercially available electrometer for measuring the generated charges is the UNIDOS by PTW Freiburg. Depending on the expected dose values, the ionisation chamber used can be selected. In addition, measurements have been performed by using commercially available area dosemeters, e.g. the Mini SmartION 2120S by Thermo Scientific, using an ionisation chamber and the Szintomat 6134 A/H by Automess, using a scintillation detector. (authors)

  17. Comparison of design features and mechanical properties of commercially available Veress needles.

    Science.gov (United States)

    Schramel, Johannes P; Kindslehner, Angelika; Bockstahler, Barbara A; Dupré, Gilles P

    2017-10-01

    To compare design features and mechanical properties of 13 commercially available Veress needles (VN). In vitro biomechanical study. Veress needles from 9 manufacturers (6 reusable, 6 disposable, and 1 with a reusable stylet combined with a disposable cannula) were included in the study. Veress needles are designed with a spring-loaded stylet to protect the tip of the cannula following insertion into the abdomen. Stylet forces were measured with a scale in a test jig by moving the stylet in 0.5 mm steps into the hollow cannula. Forces and spring rates were derived from force-displacement plots. Mass, mechanical dimensions, and the bevel angle and geometry were assessed. Differences between VN models were analyzed with a univariate analysis of variance. Results are reported as mean ± SD or median (range). Physical and mechanical parameters differed between models. The exposed stylet length was 3.5 mm (2-7). Three bevel geometries (bias, lancet type, and back-cut) with angles between 20° and 40° were identified. Reusable VN weigh more (24.9 ± 2.2 g) than disposable designs (6.0 ± 2.3 g). The mean values for the spring rate and the residual stylet force were 0.23 ± 0.08 Nmm -1 and 0.94 ± 0.28 N, respectively. The mean force required to move the stylet to the cannula tip was 1.81 ± 0.29 N and 2.77 ± 0.54 N to move to the proximal end of the bevel. Commercially available VN use diverse bevel geometries and have different mechanical characteristics. Studies investigating laparoscopic entry complications should explicitly report the type of VN model used. © 2017 The American College of Veterinary Surgeons.

  18. Determination of 210Po concentration in commercially available infant formulae and assessment of daily ingestion dose

    Directory of Open Access Journals (Sweden)

    Ravi K. Prabhath

    2015-07-01

    Full Text Available A study has been conducted to estimate the concentration of natural radioactive polonium in commercially available packaged infant food formulae available in Mumbai, India and the corresponding daily dose normalized based on its shelf life. Eleven most popular international brands of infant formulae were sourced from market and three aliquots from each sample were analysed for concordant results. Autodeposition method onto a silver planchet from hot dilute acid solution followed by alpha spectrometry was performed for estimation of polonium. Radiochemical recovery was ascertained by the addition of 209Po tracer. Radiochemical recovery of 209Po tracer was ranged from 14.7 to 98.1 %. The 210Po concentration in the samples was in the range of 0.08–0.23 Bq kg−1 on measured date and the corresponding daily dose, calculated on normalized date which is at mid-point of the shelf life of the sample, was ranged from 0.04 to 0.89 μSv d−1 as per the recommended daily consumption. The annual committed effective dose estimated based on the average of daily dose was found to be 150 μSv.

  19. Questionable diagnostic benefit of the commercially available panel of bee venom components.

    Science.gov (United States)

    Arzt, L; Bokanovic, D; Schrautzer, C; Schwarz, I; Laipold, K; Aberer, W; Sturm, G J

    2017-09-01

    For many years, only the major allergen rApi m 1 has been available on the ImmunoCAP system for routine diagnosis of bee venom (BV) allergy. Now, there are five components available, and we aimed to detect the sensitivity and specificity of rApi m 1, 2, 3, 5, and 10 in BV-allergic patients. We further evaluated the sensitivity of rApi m 1 and 2 of an alternative platform and investigated possible differences in the sensitization profile between monosensitization and clinically relevant double sensitization. Analysis of the whole panel of BV allergens of the CAP system still resulted in a lower sensitivity than analysis of the combination of rApi m 1 and 2 of the Immulite (71.6% vs 85.8%). Sensitization rate of rApi m 5 was more than doubled in double-sensitized patients, while there was no difference for rApi m 2. The benefit of the commercially available panel of BV components is questionable, due to the insufficient sensitivity and still unavailable important cross-reacting allergens. © 2017 EAACI and John Wiley and Sons A/S. Published by John Wiley and Sons Ltd.

  20. Comparative evaluation of commercially available HCG radioimmunoassays and the use of HCG as a tracer substance

    International Nuclear Information System (INIS)

    Bodemann, C.

    1985-01-01

    In view of the special oncological aspects involved in the use of HCG and β-HCG as tracer substances in radioimmunological procedures to diagnose and follow-up gynecological carcinomas, it is obvious that commercially available RIA kits must be examined for reliability before they are employed on a broader basis in connection with routine laboratory investigations. Thus, those assays were tested for convenient handling, accuracy, slope of standard curve, sensitivity, specifity and precision of tests tools against commercial control sera, pooled sera rich in HCG as well as so-called normal sera; in some cases, further evaluations were made using LH standard preparations. Due to differences between the WHO standard preparations and the fact that the manufacturers' instructions for use also deviated from one another, follow-up observations in patients showing ovarian carcinomas were likewise taken into account and served as additional reference data. A total of 8 (β-) HCG RIA test kits were examined. From among these, only the 125I-Chorionic Gonadotropin β-Subunit Kit (RSL) and the HCG-β-RIA (Cambridge) were found to lead to satisfactory measurements of (β-) HCG, with the intraassay and interassay variations remaining within acceptable limits, and to show an adequate slope of the standard curves in the low measurement ranges as well as a sufficient degree of sensitivity and specifity. The particular value of methods of detection for (β-) HCG is explained by the complete lack of any other parameters suitable for the surveillance of ovarian carcinomas. The fact that any progress or remission of those tumours may be reflected by changes in the measured HCG values accounts for the great significance of (β-) HCG as a tracer substance, which is only equalled by that of TPA and CEA. In all other genital tumours, HCG determinations cannot be substituted for the more conventional diagnostic procedures. (TRV) [de

  1. COMPARISON OF SIX COMMERCIALLY-AVAILABLE DNA POLYMERASES FOR DIRECT PCR

    Directory of Open Access Journals (Sweden)

    Masashi Miura

    2013-12-01

    Full Text Available SUMMARY The use of a “direct PCR” DNA polymerase enables PCR amplification without any prior DNA purification from blood samples due to the enzyme's resistance to inhibitors present in blood components. Such DNA polymerases are now commercially available. We compared the PCR performance of six direct PCR-type DNA polymerases (KOD FX, Mighty Amp, Hemo KlenTaq, Phusion Blood II, KAPA Blood, and BIOTAQ in dried blood eluted from a filter paper with TE buffer. GoTaq Flexi was used as a standard DNA polymerase. PCR performance was evaluated by a nested PCR technique for detecting Plasmodium falciparum genomic DNA in the presence of the blood components. Although all six DNA polymerases showed resistance to blood components compared to the standard Taq polymerase, the KOD FX and BIOTAQ DNA polymerases were resistant to inhibitory blood components at concentrations of 40%, and their PCR performance was superior to that of other DNA polymerases. When the reaction mixture contained a mild detergent, only KOD FX DNA polymerase retained the original amount of amplified product. These results indicate that KOD FX DNA polymerase is the most resistant to inhibitory blood components and/or detergents. Thus, KOD FX DNA polymerase could be useful in serological studies to simultaneously detect antibodies and DNA in eluents for antibodies. KOD FX DNA polymerase is thus not limited to use in detecting malaria parasites, but could also be employed to detect other blood-borne pathogens.

  2. Evaluation of Two Commercially Available Cannabidiol Formulations for use in Electronic Cigarettes

    Directory of Open Access Journals (Sweden)

    Michelle R Peace

    2016-08-01

    Full Text Available With 24 states and the District of Columbia with laws legalizing marijuana in some form, suppliers of legal marijuana have developed Cannabis sativa products for use in electronic cigarettes. Personal battery powered vaporizers or electronic cigarettes were developed to deliver a nicotine vapor such that smokers could simulate smoking tobacco without the inherent pathology of inhaled tobacco smoke. The liquid formulations used in these devices are comprised of an active ingredient such as nicotine mixed with glycerin and/or propylene glycol and flavorings. A significant active ingredient of Cannabis sativa, cannabidiol, has been purported to have anti-convulsant, anti-nociceptive, and anti-psychotic properties. These properties have potential medical therapies such as intervention of addictive behaviors, treatments for epilepsy, management of pain for cancer patients, and treatments for schizophrenia. However, cannabidiol extracted from Cannabis sativa remains a DEA Schedule I drug since it has not been approved by the FDA for medical purposes. Two commercially available e-cigarette liquid formulations reported to contain 3.3 mg/mL of cannabidiol as the active ingredient were evaluated. These products are not regulated by the Food and Drug Administration in manufacturing or in labeling of the products and were found to contain 6.5 mg/mL and 7.6 mg/mL of cannabidiol in propylene glycol with a variety of flavoring agents. Presently, while labeled as to content, the quality control of manufacturers and the relative safety of these products is uncertain.

  3. Comparative antibacterial effectiveness of alcohol and herbal based commercially available hand antiseptics

    Directory of Open Access Journals (Sweden)

    K Vipin Jain

    2013-01-01

    Full Text Available Background: Human skin is a reservoir of numerous microorganisms. Even though hand washing with soap and water alone reduces the microbial load, the complementary uses of hand antiseptics enhance the antimicrobial effect. Aim: To compare the antimicrobial effectiveness of two commercially available hand antiseptics, routinely used in dental practice, after hand washing with antiseptic soap. Method: A clinical trial with cross over design was carried out on 12 health care workers (HCWs. The antibacterial effectiveness of two hand antiseptics (Alcohol based -Sterillium and Herbal Based-Himalaya′s ′Pure Hands′ compared using fingerprint contact sampling on blood agar. Bacterial samples were obtained before and after hand washing (with antiseptic soap and after hand disinfection. The data was tabulated and analyzed using one way ANOVA and Tukey′s post hoc test for pair-wise comparison. Result: There was a slight decrease in the Colony forming units (CFUs count following use of antiseptic soap when compared to the baseline values. A statistically significant reduction (p<0.000 in the CFUs count was seen following use of both hand antiseptics but the mean number of CFUs reduction was more in case of alcohol based hand antiseptic(sterillium than herbal based hand antiseptic(Himalaya′s ′PureHands". Conclusion: Using alcohol based antiseptic soap before hygienic hand disinfection will provide maximum benefit in reducing the microbial count.

  4. Glucuronoyl Esterase Screening and Characterization Assays Utilizing Commercially Available Benzyl Glucuronic Acid Ester

    Directory of Open Access Journals (Sweden)

    Hampus Sunner

    2015-09-01

    Full Text Available Research on glucuronoyl esterases (GEs has been hampered by the lack of enzyme assays based on easily obtainable substrates. While benzyl d-glucuronic acid ester (BnGlcA is a commercially available substrate that can be used for GE assays, several considerations regarding substrate instability, limited solubility and low apparent affinities should be made. In this work we discuss the factors that are important when using BnGlcA for assaying GE activity and show how these can be applied when designing BnGlcA-based GE assays for different applications: a thin-layer chromatography assay for qualitative activity detection, a coupled-enzyme spectrophotometric assay that can be used for high-throughput screening or general activity determinations and a HPLC-based detection method allowing kinetic determinations. The three-level experimental procedure not merely facilitates routine, fast and simple biochemical characterizations but it can also give rise to the discovery of different GEs through an extensive screening of heterologous Genomic and Metagenomic expression libraries.

  5. Techno-functional and nutritional performance of commercial breads available in Europe.

    Science.gov (United States)

    Conte, Paola; Fadda, Costantino; Piga, Antonio; Collar, Concha

    2016-10-01

    In recent years, the growing interest for well-being and healthy lifestyle together with an increasing awareness of the close relationship between food and health have boosted the production of an increasing number of novel goods to be placed in both gluten-containing and gluten-free products market. The objective of this study was to provide a realistic and detailed overview of the current bread-market supply in order to evaluate the overall quality of the available offer in this prioritized food industry area. Twenty commercial breads consisting of gluten (n = 10) and gluten-free (n = 10) samples currently available in the European market have been assessed by physical-chemical, technological, nutritional, and sensory determinations. The quality parameters obtained were related to each other by using Pearson correlations, while sample classification was achieved by applying factor analysis. Higher values for protein and bio-accessible polyphenols content, aroma and taste quality, and low and moderate expected glycaemic index corresponded to gluten containing breads. Although the main distinction was between gluten and gluten-free samples as it was expected, classification of breads allowed differentiating samples with different formulations in terms of presence/absence of alternative, innovative, and nutrient-dense raw materials. © The Author(s) 2016.

  6. Sintered FeCuRe Alloys Produced from Commercially Available Powders

    Directory of Open Access Journals (Sweden)

    Borowiecka-Jamrozek J.

    2017-09-01

    Full Text Available This paper discusses the mechanical properties of materials fabricated from commercially available powders designed for use as a metal matrix of diamond-impregnated composites. The powders with the catalogue numbers CSA and CSA800 produced in China were tested under laboratory conditions. The specimens were fabricated in a graphite mould using hot pressing. The materials were analysed for density, porosity, hardness and static tensile strength. A scanning electron microscope (SEM was employed to observe the microstructure and fracture surfaces of the specimens. The experimental data was used to determine how the chemical composition of the powders and the process parameters affected the microstructure and properties of the materials. The properties of the sintered materials produced from the Chinese powders were compared with the properties reported for specimens fabricated from cobalt powder (Co SMS. Even though the hot pressed CSA and CSA800 powders had inferior mechanical properties to their cobalt analogue, they seem well-suited for general-purpose diamond-impregnated tools with less demanding applications.

  7. Characterization by Gas Chromatography-Mass Spectrometry of Commercially Available Thinner in the City of Cartagena

    Directory of Open Access Journals (Sweden)

    Jesus Olivero

    2013-09-01

    Full Text Available Thinner is a widely used product in the industry of paints, lubricants and adhesives. Its composition varies according to its use and quality. However, its chronic exposure is a concern, because it can affect major organs such as lungs, liver, kidney and the adrenal glands. This study characterizes the composition of several thinner samples commercially available in the city of Cartagena. Twelve samples were collected in different stores, these were then analyzed through gas chromatography coupled to mass spectrometry (GC/MS. The results showed that not only the composition but also the relative distribution of the components present in the samples are variable. Thirty two compounds were detected: toluene, o-xylene, p-xylene and ethylbenzene —among others— with occurrence frequencies of 91.7, 66.7, 75, and 66.7 %, respectively. The lack of knowledge regarding the risk of poisoning, produced when handling this type of mixtures, may be the cause of many health problems in people exposed to thinner, both in workplace and domestic activities. A data mining showed the potential association between thinner components and clinical manifestations, which include kidney and liver damage, hair loss, haematological disorders, dermatitis, anxiety and balance problems, among others. In conclusion, thinner has large variability, both in terms of components and of their relative composition. The adverse health effects of direct or indirect exposure to these components have been widely described in the literature.

  8. Chemical and toxicological characterization of commercial smokeless tobacco products available on the Canadian market.

    Science.gov (United States)

    Rickert, W S; Joza, P J; Trivedi, A H; Momin, R A; Wagstaff, W G; Lauterbach, J H

    2009-03-01

    Some health experts are recommending that smokers who refuse to quit or refuse to use nicotine replacement therapy (NRT) such as nicotine-containing chewing gum switch to certain types of smokeless tobacco products (STP) such as Swedish snus. Other health experts disagree citing the uncertainty in the composition of commercially available STP, the lack of governmental regulations to ensure that STP advertised to meet certain standards (i.e., GothiaTek) do actually meet such standards, and the uncertainty that any STP can provide as safe as alternative to smoking as NRT. One reason for uncertainty is the dearth of detailed chemical and toxicological information on contemporary STP. Unlike the situation with cigarettes, there are few standardized methods for analytical and toxicological studies of STP. Consequently, the objective for this work was to characterize several types of STP available on the Canadian market using the modifications of the Official Health Canada chemical and toxicological methods developed for cigarettes. Moist snuff samples tested had TSNA and B[a]P levels somewhat above the GothiaTek standard while samples of Swedish snus, low-moisture snuff, and US-style chewing tobacco did not. Use of in vitro assays to assess STP toxicity was of limited utility in distinguishing product types.

  9. Manufacturing technology of AS-SOFC prepared with different commercially available precursors

    Directory of Open Access Journals (Sweden)

    Kawalec M.

    2016-01-01

    Full Text Available Fuel cells are devices converting the chemical energy into the electrical energy and heat as result of the electrochemical reaction between gaseous fuel and a gas oxidant in flameless combustion process. Because of omission of thermo-mechanical steps that are present in any traditional energy conversion technology (e.g. gas turbine fuel cells show increased efficiency in comparison. Compact sizes and modular scalability predestines this technology for distributed energy generation including but not limited to renewable energy sources (e.g. wind, solar. Fuel cells technology also addresses other very important part of distributed renewable energy generation. Because of the unreliable energy production rates and the usual for renewable energy sources mismatch between energy supply and demand, some sort of energy storage is needed to store surplus of produced energy and release it when needed. Reversible fuel cells, that generate hydrogen from available surplus of energy and then generate energy from that stored fuel when needed are cheaper and more ecologically friendly alternative to usually used batteries. This technology is still under development, including research at IEn OC CEREL. In the early development of reversible fuel cells, new types of nickel oxide and porosity forming carbon was evaluated for this task. This work compares the electrical and mechanical parameters of SOFC manufactured with JT Backer NiO and Carbon Polska carbon with cells made from other commercially available materials. Based on evaluated quality, purity, availability and cost, following materials were selected for comparison: Novamet NiO, 99,9 % pure, grain size 1-2 µm and Aldrich carbon with parameters similar to graphite used previously. Preliminary tests show clear changes in the microstructural, mechanical and electrical parameters.

  10. Microbiological survey of commercial tattoo and permanent makeup inks available in the United States.

    Science.gov (United States)

    Nho, S W; Kim, S-J; Kweon, O; Howard, P C; Moon, M S; Sadrieh, N K; Cerniglia, C E

    2018-05-01

    Tattooing and use of permanent makeup (PMU) has dramatically increased over the last decade, with a concomitant increase in ink-related infections. The aim of this study was to determine whether micro-organisms are present, and if so, the number and their identification in the commercial tattoo and PMU inks available in the United States. We surveyed 85 unopened tattoo and PMU inks, purchased from 13 companies. We incubated 100 μl of ink samples on trypticase soy agar plates for bacterial growth, 7H10 Middlebrook medium for mycobacterial growth, and Sabouraud dextrose medium for fungal growth. In total, 42 inks were contaminated with micro-organisms (49%). Thirty-three inks were contaminated with bacteria, 2 inks with fungi, and 7 inks had both bacterial and fungal growth. Mycobacteria were not detected in any of the examined tattoo and PMU inks. In 26 inks, microbial concentrations ranged between 10 1 and 10 3 CFU per ml, but higher counts (>10 3 CFU per ml) were recorded in 16 inks. We identified 83 bacteria by their 16S rDNA sequences, including 20 genera and 49 species. Strains of Bacillus spp. (53%) were dominant, followed by Lysinibacillus fusiformis (7%) and Pseudomonas aeruginosa (5%). Thirty-four (41%) possibly clinically relevant strains were identified, including P. aeruginosa, Dermacoccus barathri and Roseomonas mucosa, some of which have been previously reported to be associated with human skin infections. The results indicate that commercial tattoo and PMU inks on the US market surveyed in this study contain a wide range of micro-organisms, including pathogenic bacteria. Microbial contaminants in tattoo and PMU inks are an emerging safety concern for public health. This study provides evidence that microbial contamination of tattoo and PMU inks available in the United States is more common than previously thought and highlights the importance of monitoring these products for potentially pathogenic micro-organisms. Published 2018. This article is a U

  11. Output levels of commercially available portable compact disc players and the potential risk to hearing.

    Science.gov (United States)

    Fligor, Brian J; Cox, L Clarke

    2004-12-01

    To measure the sound levels generated by the headphones of commercially available portable compact disc players and provide hearing healthcare providers with safety guidelines based on a theoretical noise dose model. Using a Knowles Electronics Manikin for Acoustical Research and a personal computer, output levels across volume control settings were recorded from headphones driven by a standard signal (white noise) and compared with output levels from music samples of eight different genres. Many commercially available models from different manufacturers were investigated. Several different styles of headphones (insert, supra-aural, vertical, and circumaural) were used to determine if style of headphone influenced output level. Free-field equivalent sound pressure levels measured at maximum volume control setting ranged from 91 dBA to 121 dBA. Output levels varied across manufacturers and style of headphone, although generally the smaller the headphone, the higher the sound level for a given volume control setting. Specifically, in one manufacturer, insert earphones increased output level 7-9 dB, relative to the output from stock headphones included in the purchase of the CD player. In a few headphone-CD player combinations, peak sound pressure levels exceeded 130 dB SPL. Based on measured sound pressure levels across systems and the noise dose model recommended by National Institute for Occupational Safety and Health for protecting the occupational worker, a maximum permissible noise dose would typically be reached within 1 hr of listening with the volume control set to 70% of maximum gain using supra-aural headphones. Using headphones that resulted in boosting the output level (e.g., insert earphones used in this study) would significantly decrease the maximum safe volume control setting; this effect was unpredictable from one manufacturer to another. In the interest of providing a straightforward recommendation that should protect the hearing of the majority of

  12. Multi-institutional Validation Study of Commercially Available Deformable Image Registration Software for Thoracic Images

    International Nuclear Information System (INIS)

    Kadoya, Noriyuki; Nakajima, Yujiro; Saito, Masahide; Miyabe, Yuki; Kurooka, Masahiko; Kito, Satoshi; Fujita, Yukio; Sasaki, Motoharu; Arai, Kazuhiro; Tani, Kensuke; Yagi, Masashi; Wakita, Akihisa; Tohyama, Naoki; Jingu, Keiichi

    2016-01-01

    Purpose: To assess the accuracy of the commercially available deformable image registration (DIR) software for thoracic images at multiple institutions. Methods and Materials: Thoracic 4-dimensional (4D) CT images of 10 patients with esophageal or lung cancer were used. Datasets for these patients were provided by DIR-lab ( (dir-lab.com)) and included a coordinate list of anatomic landmarks (300 bronchial bifurcations) that had been manually identified. Deformable image registration was performed between the peak-inhale and -exhale images. Deformable image registration error was determined by calculating the difference at each landmark point between the displacement calculated by DIR software and that calculated by the landmark. Results: Eleven institutions participated in this study: 4 used RayStation (RaySearch Laboratories, Stockholm, Sweden), 5 used MIM Software (Cleveland, OH), and 3 used Velocity (Varian Medical Systems, Palo Alto, CA). The ranges of the average absolute registration errors over all cases were as follows: 0.48 to 1.51 mm (right-left), 0.53 to 2.86 mm (anterior-posterior), 0.85 to 4.46 mm (superior-inferior), and 1.26 to 6.20 mm (3-dimensional). For each DIR software package, the average 3-dimensional registration error (range) was as follows: RayStation, 3.28 mm (1.26-3.91 mm); MIM Software, 3.29 mm (2.17-3.61 mm); and Velocity, 5.01 mm (4.02-6.20 mm). These results demonstrate that there was moderate variation among institutions, although the DIR software was the same. Conclusions: We evaluated the commercially available DIR software using thoracic 4D-CT images from multiple centers. Our results demonstrated that DIR accuracy differed among institutions because it was dependent on both the DIR software and procedure. Our results could be helpful for establishing prospective clinical trials and for the widespread use of DIR software. In addition, for clinical care, we should try to find the optimal DIR procedure using thoracic 4D

  13. Comparative performance of a panel of commercially available antimicrobial nanocoatings in Europe

    Directory of Open Access Journals (Sweden)

    Molling JW

    2014-11-01

    Full Text Available Johan W Molling, Jacques W Seezink, Birgit EJ Teunissen, Inhua Muijrers-Chen, Paul JA Borm Zuyd University of Applied Sciences, Heerlen, the Netherlands Background: Bacterial resistance against the classic antibiotics is posing an increasing challenge for the prevention and treatment of infections in health care environments. The introduction of antimicrobial nanocoatings with active ingredients provides alternative measures for active killing of microorganisms, through a preventive hygiene approach. Purpose: The purpose of this study was to investigate the antimicrobial activity of a panel of antimicrobial coatings available on the European market. Methods: A comparative, biased selection of commercially available antimicrobial coatings was tested for antimicrobial efficiency. Suppliers were contacted to deliver their coatings on glass and/or stainless steel substrates. In total, 23 coatings from eleven suppliers were received, which were investigated for their effect on the growth of Escherichia coli, using the International Organization for Standardization (ISO 22196 protocol. Results: The majority of nanomaterial-containing coatings (n=13 contained nanosilver (n=12, while only one had photocatalytic TiO2 as the active particle. The differences in antimicrobial activity among all of the coatings, expressed as log reduction values, varied between 1.3 and 6.6, while the variation within the nanomaterial-based group was between 2.0 and 6.2. Although nanosilver coatings were on average very effective in reducing the number of viable bacteria after challenge, the strongest log reduction (6.6 was seen with a coating that has immobilized, covalently bound quaternary ammonium salt in its matrix. Besides these two compounds, coatings containing TiO2, poly(dimethylsiloxane, triclosan, or zinc pyrithione evoked 100% killing of E. coli. Conclusion: Our findings indicate that nanosilver dominates the nanoparticle-based coatings and performs adequately

  14. In vitro evaluation of transdermal nicotine delivery systems commercially available in Brazil

    Directory of Open Access Journals (Sweden)

    André Luís Morais Ruela

    2013-09-01

    Full Text Available The aim of this study was to develop and validate a method for evaluating the release and skin permeation from transdermal nicotine patches using the vertical diffusion cell (VDC. The VDC is an experimental apparatus employed in research, development, and the pharmaceutical field because it can simulate conditions closest to those established in clinical trials. Two transdermal nicotine delivery systems marketed in Brazil to release 14 mg over 24 hours were evaluated. Release studies were carried out using a regenerated cellulose dialysis membrane and permeation studies were carried out using excised porcine ear skin. The results indicated that nicotine release from both evaluated patches follows Higuchi's release kinetics, while skin permeation studies indicated zero-order release kinetics. Nicotine release rates were different between both evaluated patches, but drug permeation rates were not significantly different. According to validation studies, the method was appropriate for evaluating in vitro performance of nicotine patches. The proposed method can be applied to in vitro comparative studies between different commercial nicotine patches and may be used as an auxiliary tool in the design of new transdermal nicotine delivery systems.

  15. Effects of simulated space environmental parameters on six commercially available composite materials

    International Nuclear Information System (INIS)

    Funk, J.G.; Sykes, G.F. Jr.

    1989-04-01

    The effects of simulated space environmental parameters on microdamage induced by the environment in a series of commercially available graphite-fiber-reinforced composite materials were determined. Composites with both thermoset and thermoplastic resin systems were studied. Low-Earth-Orbit (LEO) exposures were simulated by thermal cycling; geosynchronous-orbit (GEO) exposures were simulated by electron irradiation plus thermal cycling. The thermal cycling temperature range was -250 F to either 200 F or 150 F. The upper limits of the thermal cycles were different to ensure that an individual composite material was not cycled above its glass transition temperature. Material response was characterized through assessment of the induced microcracking and its influence on mechanical property changes at both room temperature and -250 F. Microdamage was induced in both thermoset and thermoplastic advanced composite materials exposed to the simulated LEO environment. However, a 350 F cure single-phase toughened epoxy composite was not damaged during exposure to the LEO environment. The simuated GEO environment produced microdamage in all materials tested

  16. Silver nanoparticle release from commercially available plastic food containers into food simulants

    DEFF Research Database (Denmark)

    Mackevica, Aiga; Olsson, Mikael Emil; Hansen, Steffen Foss

    2016-01-01

    . In the current study, we investigated four brands of commercially available plastic food storage containers and measured the total amount of silver, particle size and number concentration, and the migration rates into three different food simulants (Milli-Q grade water, 10 % ethanol, and 3 % acetic acid) for 10...... days at 40 °C. The experimental setup was made according to the European Commission Directive (EU 10/2011) for articles intended to be in contact with food. The total amount of silver in plastic containers and migration solutions was quantified by ICP-MS analysis, and the size of the migrated particles...... was investigated by single particle ICP-MS and TEM-EDS. The total mass and median size of released particulate Ag were generally highest in 3 % acetic acid for three out of four food container brands. The total content of silver in the containers varied from 13 to 42 µg/g. The highest migration was observed...

  17. Analysis of two commercially available bortezomib products: differences in assay of active agent and impurity profile.

    Science.gov (United States)

    Byrn, Stephen R; Tishmack, Patrick A; Milton, Mark J; van de Velde, Helgi

    2011-06-01

    The analytical properties of two commercially available bortezomib products (VELCADE(®) and Bortenat) were compared using nuclear magnetic resonance, mass spectrometry, high-performance liquid chromatography, and gas chromatography. The data showed differences between the two products. Based on these data, Bortenat samples contained more active ingredients than indicated by the label (mean, 116.5% and 117.9% of label, in 2-mg and 3.5-mg vials, respectively). In comparison, VELCADE samples contained a mean of 99.3% of active ingredient, which was consistent with the approved specification range (US, 90-110%; EU, 95-105%). Clinical data demonstrate that patients exposed to higher than recommended doses of bortezomib on the standard twice-weekly dosing schedule are likely to have an increased risk of major toxicities. Bortenat 2-mg vials contained an isovaleraldehyde impurity; the origin of this is unknown. Additionally, the ratio of boronic acid to boronic ester differed between Bortenat 2 mg (0.27:1) and 3.5 mg (0.13:1) and VELCADE (0.10:1) samples reconstituted in saline indicating that the Bortenat product is not equivalent to the VELCADE product.

  18. Assessment of commercially available ion exchange materials for cesium removal from highly alkaline wastes

    International Nuclear Information System (INIS)

    Brooks, K.P.; Kim, A.Y.; Kurath, D.E.

    1996-04-01

    Approximately 61 million gallons of nuclear waste generated in plutonium production, radionuclide removal campaigns, and research and development activities is stored on the Department of Energy's Hanford Site, near Richland, Washington. Although the pretreatment process and disposal requirements are still being defined, most pretreatment scenarios include removal of cesium from the aqueous streams. In many cases, after cesium is removed, the dissolved salt cakes and supernates can be disposed of as LLW. Ion exchange has been a leading candidate for this separation. Ion exchange systems have the advantage of simplicity of equipment and operation and provide many theoretical stages in a small space. The organic ion exchange material Duolite trademark CS-100 has been selected as the baseline exchanger for conceptual design of the Initial Pretreatment Module (IPM). Use of CS-100 was chosen because it is considered a conservative, technologically feasible approach. During FY 96, final resin down-selection will occur for IPM Title 1 design. Alternate ion exchange materials for cesium exchange will be considered at that time. The purpose of this report is to conduct a search for commercially available ion exchange materials which could potentially replace CS-100. This report will provide where possible a comparison of these resin in their ability to remove low concentrations of cesium from highly alkaline solutions. Materials which show promise can be studied further, while less encouraging resins can be eliminated from consideration

  19. Comparison of commercially available radioimmunoassays for the determination of bile acids in serum

    Energy Technology Data Exchange (ETDEWEB)

    Wildgrube, H.J.; Schiller, W.; Winkler, M.; Weber, J.; Campana, H.; Mauritz, G.

    1982-05-01

    Three commercially available radioimmunoassays for the determination of bile acids in serum were evaluated with respect to specificity and precision. The SLCG-radioimmunoassay (Abbott) measures only sulphated glycolithocholic acid, the CG-radioimmunoassay (Abbott) measures chiefly cholic acid conjugates, and the CBA-radioimmunoassay (Becton-Dickinson) measures all conjugated bile acids, with an over-response to taurine metabolites. With respect to cross reactions, the performances of the CG-and the CBA-radioimmunoassays differed significantly from those stated by the manufacturers, the former showing a 32% response to taurocholic acid, the latter responding only 118% to taurochenodeoxycholic acid. At physiological concentrations of albumin + globulin, the recovery of defined cholanic acids was 85-101%. Good reproducibility was shown by the CG-radioimmunoassay in the range 0.5-10.9 ..mu..mol/l, by the CBA-radioimmunoassay in the range 1.0-25.0 ..mu..mol/l, and by the SLCG-radioimmunoassay in the range 0.5-3.0 ..mu..mol/l. There were no important differences in the inter- and intra-assay precision of the three methods.

  20. Evaluation of Two Commercially Available Cannabidiol Formulations for Use in Electronic Cigarettes.

    Science.gov (United States)

    Peace, Michelle R; Butler, Karen E; Wolf, Carl E; Poklis, Justin L; Poklis, Alphonse

    2016-01-01

    Since 24 states and the District of Columbia have legalized marijuana in some form, suppliers of legal marijuana have developed Cannabis sativa products for use in electronic cigarettes (e-cigarettes). Personal battery powered vaporizers, or e-cigarettes, were developed to deliver a nicotine vapor such that smokers could simulate smoking tobacco without the inherent pathology of inhaled tobacco smoke. The liquid formulations used in these devices are comprised of an active ingredient such as nicotine mixed with vegetable glycerin (VG) and/or propylene glycol (PG) and flavorings. A significant active ingredient of C. sativa, cannabidiol (CBD), has been purported to have anti-convulsant, anti-nociceptive, and anti-psychotic properties. These properties have potential medical therapies such as intervention of addictive behaviors, treatments for epilepsy, management of pain for cancer patients, and treatments for schizophrenia. However, CBD extracted from C. sativa remains a DEA Schedule I drug since it has not been approved by the FDA for medical purposes. Two commercially available e-cigarette liquid formulations reported to contain 3.3 mg/mL of CBD as the active ingredient were evaluated. These products are not regulated by the FDA in manufacturing or in labeling of the products and were found to contain 6.5 and 7.6 mg/mL of CBD in VG and PG with a variety of flavoring agents. Presently, while labeled as to content, the quality control of manufacturers and the relative safety of these products is uncertain.

  1. Assessment of commercially available ion exchange materials for cesium removal from highly alkaline wastes

    Energy Technology Data Exchange (ETDEWEB)

    Brooks, K.P.; Kim, A.Y.; Kurath, D.E.

    1996-04-01

    Approximately 61 million gallons of nuclear waste generated in plutonium production, radionuclide removal campaigns, and research and development activities is stored on the Department of Energy`s Hanford Site, near Richland, Washington. Although the pretreatment process and disposal requirements are still being defined, most pretreatment scenarios include removal of cesium from the aqueous streams. In many cases, after cesium is removed, the dissolved salt cakes and supernates can be disposed of as LLW. Ion exchange has been a leading candidate for this separation. Ion exchange systems have the advantage of simplicity of equipment and operation and provide many theoretical stages in a small space. The organic ion exchange material Duolite{trademark} CS-100 has been selected as the baseline exchanger for conceptual design of the Initial Pretreatment Module (IPM). Use of CS-100 was chosen because it is considered a conservative, technologically feasible approach. During FY 96, final resin down-selection will occur for IPM Title 1 design. Alternate ion exchange materials for cesium exchange will be considered at that time. The purpose of this report is to conduct a search for commercially available ion exchange materials which could potentially replace CS-100. This report will provide where possible a comparison of these resin in their ability to remove low concentrations of cesium from highly alkaline solutions. Materials which show promise can be studied further, while less encouraging resins can be eliminated from consideration.

  2. Development of a multichannel vestibular prosthesis prototype by modification of a commercially available cochlear implant.

    Science.gov (United States)

    Valentin, Nicolas S; Hageman, Kristin N; Dai, Chenkai; Della Santina, Charles C; Fridman, Gene Y

    2013-09-01

    No adequate treatment exists for individuals who remain disabled by bilateral loss of vestibular (inner ear inertial) sensation despite rehabilitation. We have restored vestibular reflexes using lab-built multichannel vestibular prostheses (MVPs) in animals, but translation to clinical practice may be best accomplished by modification of a commercially available cochlear implant (CI). In this interim report, we describe preliminary efforts toward that goal. We developed software and circuitry to sense head rotation and drive a CI's implanted stimulator (IS) to deliver up to 1 K pulses/s via nine electrodes implanted near vestibular nerve branches. Studies in two rhesus monkeys using the modified CI revealed in vivo performance similar to our existing dedicated MVPs. A key focus of our study was the head-worn unit (HWU), which magnetically couples across the scalp to the IS. The HWU must remain securely fixed to the skull to faithfully sense head motion and maintain continuous stimulation. We measured normal and shear force thresholds at which HWU-IS decoupling occurred as a function of scalp thickness and calculated pressure exerted on the scalp. The HWU remained attached for human scalp thicknesses from 3-7.8 mm for forces experienced during routine daily activities, while pressure on the scalp remained below capillary perfusion pressure.

  3. Commercially Available Activated Carbon Fiber Felt Enables Efficient Solar Steam Generation.

    Science.gov (United States)

    Li, Haoran; He, Yurong; Hu, Yanwei; Wang, Xinzhi

    2018-03-21

    Sun-driven steam generation is now possible and has the potential to help meet future energy needs. Current technologies often use solar condensers to increase solar irradiance. More recently, a technology for solar steam generation that uses heated surface water and low optical concentration is reported. In this work, a commercially available activated carbon fiber felt is used to generate steam efficiently under one sun illumination. The evaporation rate and solar conversion efficiency reach 1.22 kg m -2 h -1 and 79.4%, respectively. The local temperature of the evaporator with a floating activated carbon fiber felt reaches 48 °C. Apart from the high absorptivity (about 94%) of the material, the evaporation performance is enhanced thanks to the well-developed pores for improved water supply and steam escape and the low thermal conductivity, which enables reduced bulk water temperature increase. This study helps to find a promising material for solar steam generation using a water evaporator that can be produced economically (∼6 $/m 2 ) with long-term stability.

  4. Characterisation and potential migration of silver nanoparticles from commercially available polymeric food contact materials.

    Science.gov (United States)

    Addo Ntim, Susana; Thomas, Treye A; Begley, Timothy H; Noonan, Gregory O

    2015-01-01

    The potential for consumer exposure to nano-components in food contact materials (FCMs) is dependent on the migration of nanomaterials into food. Therefore, characterising the physico-chemical properties and potential for migration of constituents is an important step in assessing the safety of FCMs. A number of commercially available food storage products, purchased domestically within the United States and internationally, that claim to contain nanosilver were evaluated. The products were made of polyethylene, polypropylene and polyphenylene ether sulfone and all contained silver (0.001-36 mg kg(-1) of polymer). Silver migration was measured under various conditions, including using 3% acetic acid and water as food simulants. Low concentrations (sub-ppb levels) of silver were detected in the migration studies generally following a trend characterised by a surface desorption phenomenon, where the majority of the silver migration occurred in the first of three consecutive exposures. Silver nanoparticles were not detected in food simulants, suggesting that the silver migration may be due solely to ionic silver released into solution from oxidation of the silver nanoparticle surface. The absence of detectable silver nanoparticles was consistent with expectations from a physico-chemical view point. For the products tested, current USFDA guidance for evaluating migration from FCMs was applicable.

  5. Distribution of manganese and selenium in four different pork cuts commercially available in the Serbian market

    Science.gov (United States)

    Đinović-Stojanović, J.; Nikolić, D.; Janković, S.; Vranić, D.; Milijašević, M.; Babić-Milijašević, J.

    2017-09-01

    This study aimed to provide information on levels of Mn and Se in four different pork cuts (loin, neck, hind leg and shoulder) commercially available on the Serbian market, with a view to providing information on dietary intakes of metals associated with the consumption of these meat cuts. In total, for 50 pork cuts, the levels of Mn and Se were determined by inductively-coupled plasma mass spectrometry (ICP-MS). The following ranges of Mn and Se were found (mg kg-1) in loin 0.055-0.130 and 0.074-0.365, in neck 0.014-0.365 and 0.045-0.196, in hind leg 0.032-0.099 and 0.066-0.123, in shoulder 0.012-0.290 and 0.027-0.515, respectively. The highest mean levels were obtained for Mn (0.124 mg kg-1) in shoulder and for Se (0.209 mg kg-1) in loin. The Estimated Daily Intake (EDI) of essential elements through consumption of 114.1 g mammalian meat/person/day was below 1% of Adequate Intake (AI) for Mn and between 18.9% and 43.2% of Recommended Dietary Allowance (RDA) for Se.

  6. Evaluation of Solid Rocket Motor Component Data Using a Commercially Available Statistical Software Package

    Science.gov (United States)

    Stefanski, Philip L.

    2015-01-01

    Commercially available software packages today allow users to quickly perform the routine evaluations of (1) descriptive statistics to numerically and graphically summarize both sample and population data, (2) inferential statistics that draws conclusions about a given population from samples taken of it, (3) probability determinations that can be used to generate estimates of reliability allowables, and finally (4) the setup of designed experiments and analysis of their data to identify significant material and process characteristics for application in both product manufacturing and performance enhancement. This paper presents examples of analysis and experimental design work that has been conducted using Statgraphics®(Registered Trademark) statistical software to obtain useful information with regard to solid rocket motor propellants and internal insulation material. Data were obtained from a number of programs (Shuttle, Constellation, and Space Launch System) and sources that include solid propellant burn rate strands, tensile specimens, sub-scale test motors, full-scale operational motors, rubber insulation specimens, and sub-scale rubber insulation analog samples. Besides facilitating the experimental design process to yield meaningful results, statistical software has demonstrated its ability to quickly perform complex data analyses and yield significant findings that might otherwise have gone unnoticed. One caveat to these successes is that useful results not only derive from the inherent power of the software package, but also from the skill and understanding of the data analyst.

  7. Comparison of commercially-available preservatives for maintaining the integrity of bacterial DNA in human milk.

    Science.gov (United States)

    Lackey, Kimberly A; Williams, Janet E; Price, William J; Carrothers, Janae M; Brooker, Sarah L; Shafii, Bahman; McGuire, Mark A; McGuire, Michelle K

    2017-10-01

    Inhibiting changes to bacteria in human milk between sample collection and analysis is necessary for unbiased characterization of the milk microbiome. Although cold storage is considered optimal, alternative preservation is sometimes necessary. The objective of this study was to compare the effectiveness of several commercially-available preservatives with regard to maintaining bacterial DNA in human milk for delayed microbiome analysis. Specifically, we compared Life Technologies' RNAlater® stabilization solution, Biomatrica's DNAgard® Saliva, Advanced Instruments' Broad Spectrum Microtabs II™, and Norgen Biotek Corporation's Milk DNA Preservation and Isolation Kit. Aliquots of 8 pools of human milk were treated with each preservative. DNA was extracted immediately and at 1, 2, 4, and 6wk, during which time milk was held at 37°C. The V1-V3 region of the bacterial 16S rRNA gene was amplified and sequenced. Changes in bacterial community structure and diversity over time were evaluated. Comparable to other studies, the most abundant genera were Streptococcus (33.3%), Staphylococcus (14.0%), Dyella (6.3%), Pseudomonas (3.0%), Veillonella (2.5%), Hafnia (2.0%), Prevotella (1.7%), Rhodococcus (1.6%), and Granulicatella (1.4%). Overall, use of Norgen's Milk DNA Preservation and Isolation Kit best maintained the consistency of the bacterial community structure. Total DNA, diversity, and evenness metrics were also highest in samples preserved with this method. When collecting human milk for bacterial community analysis in field conditions where cold storage is not available, our results suggest that Norgen's Milk DNA Preservation and Isolation Kit may be a useful method, at least for a period of 2weeks. Copyright © 2017 Elsevier B.V. All rights reserved.

  8. Retinal Oximetry and Vessel Diameter Measurements With a Commercially Available Scanning Laser Ophthalmoscope in Diabetic Retinopathy.

    Science.gov (United States)

    Blair, Norman P; Wanek, Justin; Felder, Anthony E; Joslin, Charlotte E; Kresovich, Jacob K; Lim, Jennifer I; Chau, Felix Y; Leiderman, Yannek; Shahidi, Mahnaz

    2017-10-01

    To test the hypothesis that retinal vascular diameter and hemoglobin oxygen saturation alterations, according to stages of diabetic retinopathy (DR), are discernible with a commercially available scanning laser ophthalmoscope (SLO). One hundred eighty-one subjects with no diabetes (No DM), diabetes with no DR (No DR), nonproliferative DR (NPDR), or proliferative DR (PDR, all had photocoagulation) underwent imaging with an SLO with dual lasers (532 nm and 633 nm). Customized image analysis software determined the diameters of retinal arteries and veins (DA and DV) and central retinal artery and vein equivalents (CRAE and CRVE). Oxygen saturations of hemoglobin in arteries and veins (SO2A and SO2V) were estimated from optical densities of vessels on images at the two wavelengths. Statistical models were generated by adjusting for effects of sex, race, age, eye, and fundus pigmentation. DA, CRAE, and CRVE were reduced in PDR compared to No DM (P ≤ 0.03). DV and CRVE were similar between No DM and No DR, but they were higher in NPDR than No DR (P ≤ 0.01). Effect of stage of disease on SO2A differed by race, being increased relative to No DM in NPDR and PDR in Hispanic participants only (P ≤ 0.02). Relative to No DM, SO2V was increased in NPDR and PDR (P ≤ 0.05). Alterations in retinal vascular diameters and SO2 by diabetic retinopathy stage can be detected with a widely available SLO, and covariates such as race can influence the results.

  9. Oral bioaccessibility of toxic and essential elements in raw and cooked commercial seafood species available in European markets

    NARCIS (Netherlands)

    Alves, Ricardo N.; Maulvault, Ana L.; Barbosa, Vera L.; Fernandez-Tejedor, Margarita; Tediosi, Alice; Kotterman, Michiel; Heuvel, van den Fredericus H.M.; Robbens, Johan; Fernandes, José O.; Romme Rasmussen, Rie; Sloth, Jens J.; Marques, António

    2017-01-01

    The oral bioaccessibility of several essential and toxic elements was investigated in raw and cooked commercially available seafood species from European markets. Bioaccessibility varied between seafood species and elements. Methylmercury bioaccessibility varied between 10 (octopus) and 60%

  10. 77 FR 48108 - Energy Conservation Standards for Commercial Clothes Washers: Public Meeting and Availability of...

    Science.gov (United States)

    2012-08-13

    ... commercial matters regulated by U.S. antitrust laws. After the public meeting and the expiration of the.... Code, for editorial reasons.) The Energy Policy Act of 2005 (EPACT 2005), Public Law 109-58, further...

  11. Characterization of engineered nanoparticles in commercially available spray disinfectant products advertised to contain colloidal silver

    Science.gov (United States)

    Given the potential for human exposure to silver nanoparticles from spray disinfectants and dietary supplements, we characterized the silver-containing nanoparticles in 22 commercial products that advertised the use of silver or colloidal silver as the active ingredient. Characte...

  12. Investigation of the homogeneity of methacrylate allergens in commercially available patch test preparations

    DEFF Research Database (Denmark)

    Mose, Kristian Fredløv; Andersen, Klaus Ejner; Christensen, Lars Porskjaer

    2013-01-01

    The homogeneity of methacrylates in commercial patch test preparations has not yet been investigated. Inhomogeneous patch test preparations may give rise to false-negative or false-positive patch test results in patients suspected of having methacrylate allergy.......The homogeneity of methacrylates in commercial patch test preparations has not yet been investigated. Inhomogeneous patch test preparations may give rise to false-negative or false-positive patch test results in patients suspected of having methacrylate allergy....

  13. Effects of commercially available pneumatic compression on muscle glycogen recovery after exercise.

    Science.gov (United States)

    Keck, Nathan A; Cuddy, John S; Hailes, Walter S; Dumke, Charles L; Ruby, Brent C

    2015-02-01

    The purpose of this study was to investigate the effects of pneumatic compression pants on postexercise glycogen resynthesis. Active male subjects (n = 10) completed 2 trials consisting of a 90-minute glycogen depleting ride, followed by 4 hours of recovery with either a pneumatic compression device (PCD) or passive recovery (PR) in a random counterbalanced order. A carbohydrate beverage (1.8 g·kg bodyweight) was provided at 0 and 2 hours after exercise. Muscle biopsies (vastus lateralis) were obtained immediately and 4 hours after exercise for glycogen analyses. Blood samples were collected throughout recovery to measure glucose and insulin. Eight fingerstick blood samples for lactate were collected in the last 20 minutes of the exercise period and during the initial portion of the recovery period. Heart rate was monitored throughout the trial. During the PCD trial, subjects recovered using a commercially available recovery device (NormaTec PCD) operational at 0-60 and 120-180 minutes into recovery period. The same PCD was worn during the PR trial but was not turned on to create pulsatile pressures. There was no difference in muscle glycogen resynthesis during the recovery period (6.9 ± 0.8 and 6.9 ± 0.5 mmol·kg wet wt·h for the PR and PCD trials, respectively). Blood glucose, insulin, and lactate concentrations changed with respect to time but were not different between trials (p > 0.05). The use of PCD did not alter the rate of muscle glycogen resynthesis, blood lactate, or blood glucose and insulin concentrations associated with a postexercise oral glucose load.

  14. Silver nanoparticle release from commercially available plastic food containers into food simulants

    International Nuclear Information System (INIS)

    Mackevica, Aiga; Olsson, Mikael Emil; Hansen, Steffen Foss

    2016-01-01

    Silver nanoparticles (AgNPs) are currently being used in many different kinds of consumer products in order to take advantage of their antimicrobial properties. However, the potential migration of silver nanoparticles into food and subsequent consumer exposure has hardly been addressed. In the current study, we investigated four brands of commercially available plastic food storage containers and measured the total amount of silver, particle size and number concentration, and the migration rates into three different food simulants (Milli-Q grade water, 10 % ethanol, and 3 % acetic acid) for 10 days at 40 °C. The experimental setup was made according to the European Commission Directive (EU 10/2011) for articles intended to be in contact with food. The total amount of silver in plastic containers and migration solutions was quantified by ICP-MS analysis, and the size of the migrated particles was investigated by single particle ICP-MS and TEM-EDS. The total mass and median size of released particulate Ag were generally highest in 3 % acetic acid for three out of four food container brands. The total content of silver in the containers varied from 13 to 42 µg/g. The highest migration was observed in the 3 % acetic acid food simulant for all four brands of containers, with total silver release up to 3.1 ng/cm 2 after 10 days. In conclusion, the experimental results show that silver has the potential of migrating into food, especially when in contact with more acidic substances

  15. Cytochrome oxidase-I sequence based studies of commercially available Pangasius hypophthalmus in Italy

    Directory of Open Access Journals (Sweden)

    Federica Bellagamba

    2015-09-01

    Full Text Available Pangasius hypophthalmus is one of the fish consumed in the Italian diet. It is farmed and imported from Mekong delta region of Vietnam. Among several types of Pangasius, Tra (Pangasius hypophthalmus is permitted for sales by the European Union. Since these fish species are often allegedly substituted with other morphologically similar fish due to commercial benefits, authentication of the products in the international markets become often necessary to prevent fraud and safety issues. In addition, this fish is imported as fillets without skin and bone, thus leaving the consumer’s at the risk of buying a substandard nutritional food. In this article we present the molecular approach we developed to identify Pangasius hypophthalmus from other closely related species based on cytochrome oxidase-I (COI mitochondrial barcoding gene and further described the variants in the studied population genetic of this species. Fifty-one samples of Pangasius hypophthalmus fillets labelled as Pangasio were obtained from various markets around Milan and their COI mitochondrial barcoding gene was sequenced and studied in our bioinformatics pipeline. All samples were successfully amplified and Basic Local Alignment Search Tool results of the amplified region confirmed that all sequences analysed belonged to Pangasius hypophthalmus. Based on the variations in their barcoding region single nucleotide polymorphisms were identified and delineative statistics was calculated on the sequences. Although Pangasius hypophthalmus is considered as a monophyly, seven polymorphisms were identified. The neighbour-joining tree and the Median-joining network of haplotypes showed for all the identified haplotypes a unique cluster, with the exception of one sample.

  16. Energy dependence of commercially available diode detectors for in-vivo dosimetry

    International Nuclear Information System (INIS)

    Saini, Amarjit S.; Zhu, Timothy C.

    2007-01-01

    The energy dependence of commercially available diode detectors was measured for nominal accelerating potential ranging between Co-60 and 17 MV. The measurements were performed in a liquid water phantom at 5 cm depth for 10x10 cm 2 collimator setting and source-to-detector distance of 100 cm. The response (nC/Gy) was normalized to Co-60 beam after corrections for the dose rate and temperature dependences for each diode. The energy dependence, calculated by taking the percent difference between the maximum and minimum sensitivity normalized to Co-60 beam, varied by 39% for the n-type Isorad Red, 26% for the n-type Isorad Electron, 19% for the QED Red (p-type), 15% for the QED Electron (p-type), 11% for the QED Blue (p-type), and 6% for the EDP10 diode for nominal accelerating potential between Co-60 and 17 MV. It varied by 34% for the Isorad-3 Gold 1 and 2, 35% for the Veridose Green, 15% for the Veridose Yellow, 9% for the Veridose Electron, 21% for the n-type QED Gold, 24% for the n-type QED Red, 3% for the EDP2 3G , 2% for the PFD (photon field detector), 7% for the EDP10 3G , and 16% for the EDP20 3G for nominal accelerating potential between Co-60 and 15 MV. The magnitude of the energy dependence is verified by Monte Carlo simulation. We concluded that the energy dependence does not depend on whether the diode is n- or p-type but rather depends mainly on the material around the die such as the buildup and the geometry of the buildup material. As a result, the value of the energy dependence can vary for each individual diode depending on the actual geometry and should be used with caution

  17. Silver nanoparticle release from commercially available plastic food containers into food simulants

    Energy Technology Data Exchange (ETDEWEB)

    Mackevica, Aiga, E-mail: aima@env.dtu.dk; Olsson, Mikael Emil; Hansen, Steffen Foss [Technical University of Denmark, Department of Environmental Engineering (Denmark)

    2016-01-15

    Silver nanoparticles (AgNPs) are currently being used in many different kinds of consumer products in order to take advantage of their antimicrobial properties. However, the potential migration of silver nanoparticles into food and subsequent consumer exposure has hardly been addressed. In the current study, we investigated four brands of commercially available plastic food storage containers and measured the total amount of silver, particle size and number concentration, and the migration rates into three different food simulants (Milli-Q grade water, 10 % ethanol, and 3 % acetic acid) for 10 days at 40 °C. The experimental setup was made according to the European Commission Directive (EU 10/2011) for articles intended to be in contact with food. The total amount of silver in plastic containers and migration solutions was quantified by ICP-MS analysis, and the size of the migrated particles was investigated by single particle ICP-MS and TEM-EDS. The total mass and median size of released particulate Ag were generally highest in 3 % acetic acid for three out of four food container brands. The total content of silver in the containers varied from 13 to 42 µg/g. The highest migration was observed in the 3 % acetic acid food simulant for all four brands of containers, with total silver release up to 3.1 ng/cm{sup 2} after 10 days. In conclusion, the experimental results show that silver has the potential of migrating into food, especially when in contact with more acidic substances.

  18. Effects of Gamma Irradiation and Pasteurization on the Nutritive Composition of Commercially Available Animal Diets

    Science.gov (United States)

    Caulfield, Catherine D; Cassidy, Joseph P; Kelly, John P

    2008-01-01

    Gamma radiation is used to sterilize diets for specific pathogen-free (SPF) animals. Because a gamma-irradiated diet was linked to leukoencephalomyelopathy in SPF cats, we investigated the effects of ‘typical’ (28.9–34.3 kGy) and ‘high-end’ (38.4–48.7 kGy) doses of gamma irradiation and of pasteurization (at 107 °C for 15 min) on the amounts of fat; protein; carbohydrate (and taurine in cat diet); vitamins A, E, B1, B2, B6, and B12; and peroxide in commercially available dry cat, dog, and rodent diets. The only treatment-related changes occurred with vitamin A and peroxide. The typical and high-end doses of gamma irradiation reduced the vitamin A level of the cat diet to 42% and 30% of the untreated value, respectively—levels below recommended allowances for growth and reproduction. Only the higher irradiation dose reduced vitamin A in the rodent diet, and neither dose altered the canine diet. Pasteurization reduced the vitamin A content of the cat diet to 50% of its original level, which was within the recommended level for this species. Irradiation increased the peroxide content of all 3 animal diets: by approximately 11-fold with the typical dose and by 14- to 25-fold with the high-end dose. Therefore gamma irradiation can have profound, selective effects on the vitamin A and peroxide contents of dry diets, and caution is advised when feeding such diets long-term and exclusively to SPF animals, particularly cats. Furthermore, pasteurization (with its fewer deleterious effects) may represent an alternative method of decontaminating diets for rodents, dogs, and cats. PMID:19049256

  19. Physico-mechanical characteristics of commercially available bulk-fill composites.

    Science.gov (United States)

    Leprince, Julian G; Palin, William M; Vanacker, Julie; Sabbagh, Joseph; Devaux, Jacques; Leloup, Gaetane

    2014-08-01

    Bulk-fill composites have emerged, arguably, as a new "class" of resin-based composites, which are claimed to enable restoration in thick layers, up to 4mm. The objective of this work was to compare, under optimal curing conditions, the physico-mechanical properties of most currently available bulk-fill composites to those of two conventional composite materials chosen as references, one highly filled and one flowable "nano-hybrid" composite. Tetric EvoCeram Bulk Fill (Ivoclar-Vivadent), Venus Bulk Fill (Heraeus-Kulzer), SDR (Dentsply), X-tra Fil (VOCO), X-tra Base (VOCO), Sonic Fill (Kerr), Filtek Bulk Fill (3M-Espe), Xenius (GC) were compared to the two reference materials. The materials were light-cured for 40s in a 2mm×2mm×25mm Teflon mould. Degree of conversion was measured by Raman spectroscopy, Elastic modulus and flexural strength were evaluated by three point bending, surface hardness using Vickers microindentation before and after 24h ethanol storage, and filler weight content by thermogravimetric analysis. The ratio of surface hardness before and after ethanol storage was considered as an evaluation of polymer softening. Data were analyzed by one-way ANOVA and post hoc Tukey's test (p=0.05). The mechanical properties of the bulk-fill composites were mostly lower compared with the conventional high viscosity material, and, at best, comparable to the conventional flowable composite. Linear correlations of the mechanical properties investigated were poor with degree of conversion (0.090.8). Softening in ethanol revealed differences in polymer network density between material types. The reduction of time and improvement of convenience associated with bulk-fill materials is a clear advantage of this particular material class. However, a compromise with mechanical properties compared with more conventional commercially-available nano-hybrid materials was demonstrated by the present work. Given the lower mechanical properties of most bulk-fill materials

  20. Influence of commercially available follicle stimulating hormone on the in vitro maturation of bovine oocytes

    Directory of Open Access Journals (Sweden)

    Maria Valéria de Oliveira Santos

    2017-06-01

    Full Text Available The work aimed (Experiment I to compare commercial representations of porcine follicle stimulating hormone (FSH, Pluset® vs. Folltropin® in concentration (10 ?g/mL and time (24 h standard (more used in protocols of in vitro maturation, IVM; (Experiment II to evaluate the best incubation time (6 h vs. 16 h vs. 24 h and, (Experiment III analyze varying concentrations (1.0 ?g/mL vs. 2.5 ?g/mL vs. 10.0 ?g/mL of representations of FSH on the IVM of bovine oocytes. Thus, oocytes were recovered and submitted to IVM under appropriate conditions. After the IVM, oocytes were evaluated for expansion of cumulus cells (CCs, presence of the first polar body (1PB and metaphase plate (MII. All the data were analyzed by the Fisher exact test (P 0.05 was observed in maturation rates of the oocytes incubated with FSH Pluset® or Folltropin®, assessed by expansion of CCs (97.6% vs. 94.3%, presence of 1PB (76.6% vs. 69.4% and MII (70.0% vs. 68.6%. In Experiment II, when the incubation time with FSH was evaluated, both Pluset® as Folltropin® showed lower rate of expansion of CCs when they were present only in the first 6 h of IVM. As for presence of 1PB, differences were observed in relation to Pluset® while Folltropin® showed similar results in all incubation times. Regarding the MII, no difference was observed between the incubation times with FSH Pluset® and Folltropin®. In Experiment III, no difference was observed in the expansion of CCs, presence of 1PB and MII for concentrations evaluated FSH Pluset® and Folltropin®. Therefore, the FSH Pluset® and Folltropin® have the same efficiency in IVM of bovine oocytes. Regarding the incubation time, it is recommended to maintain FSH (Pluset® or Folltropin® throughout the period of IVM, since there was no difference in the results of presence of MII. Furthermore, the concentration of 1.0 ?g/mL of FSH Pluset® and Folltropin® is as effective as 10 ?g/mL and can therefore be used for IVM of oocytes.

  1. Benchmarking of commercially available CHO cell culture media for antibody production.

    Science.gov (United States)

    Reinhart, David; Damjanovic, Lukas; Kaisermayer, Christian; Kunert, Renate

    2015-06-01

    In this study, eight commercially available, chemically defined Chinese hamster ovary (CHO) cell culture media from different vendors were evaluated in batch culture using an IgG-producing CHO DG44 cell line as a model. Medium adaptation revealed that the occurrence of even small aggregates might be a good indicator of cell growth performance in subsequent high cell density cultures. Batch experiments confirmed that the culture medium has a significant impact on bioprocess performance, but high amino acid concentrations alone were not sufficient to ensure superior cell growth and high antibody production. However, some key amino acids that were limiting in most media could be identified. Unbalanced glucose and amino acids led to high cell-specific lactate and ammonium production rates. In some media, persistently high glucose concentrations probably induced the suppression of respiration and oxidative phosphorylation, known as Crabtree effect, which resulted in high cell-specific glycolysis rates along with a continuous and high lactate production. In additional experiments, two of the eight basal media were supplemented with feeds from two different manufacturers in six combinations, in order to understand the combined impact of media and feeds on cell metabolism in a CHO fed-batch process. Cell growth, nutrient consumption and metabolite production rates, antibody production, and IgG quality were evaluated in detail. Concentrated feed supplements boosted cell concentrations almost threefold and antibody titers up to sevenfold. Depending on the fed-batch strategy, fourfold higher peak cell concentrations and eightfold increased IgG titers (up to 5.8 g/L) were achieved. The glycolytic flux was remarkably similar among the fed-batches; however, substantially different specific lactate production rates were observed in the different media and feed combinations. Further analysis revealed that in addition to the feed additives, the basal medium can make a considerable

  2. Commercially Available Smartphone Apps to Support Postoperative Pain Self-Management: Scoping Review.

    Science.gov (United States)

    Lalloo, Chitra; Shah, Ushma; Birnie, Kathryn A; Davies-Chalmers, Cleo; Rivera, Jordan; Stinson, Jennifer; Campbell, Fiona

    2017-10-23

    Recently, the use of smartphones to deliver health-related content has experienced rapid growth, with more than 165,000 mobile health (mHealth) apps currently available in the digital marketplace. With 3 out of 4 Canadians currently owning a smartphone, mHealth apps offer opportunities to deliver accessible health-related knowledge and support. Many individuals experience pain after surgery, which can negatively impact their health-related quality of life, including sleep, emotional, and social functioning. Smartphone apps that provide remote real-time monitoring and symptom management have the potential to improve self-management skills in patients experiencing postoperative pain. Increased confidence and practice of self-management skills could contribute to decreased postoperative pain and reduce risk of developing persistent pain. Published reviews of general pain self-management apps demonstrate a lack of evidence-based content, theoretical grounding, and health care professional involvement. However, no review to date has focused on the app marketplace specific for individuals with postoperative pain. The aim of this study was to characterize and critically appraise the content and functionality of commercially available postoperative pain self-management apps. An electronic search and extraction was conducted between December 2016 and March 2017 of the official Canadian app stores for the three major smartphone operating systems (iPhone operating system [iOS], Android, and Windows). Stores were searched separately using predetermined search terms. Two authors screened apps based on information provided in the public app description. Metadata from all included apps were abstracted into a standard spreadsheet. Two authors verified the data with reference to the apps and downloaded apps themselves. The content and functionality of each app as it pertained to postoperative pain self-management was rated. A total of 10 apps met the inclusion criteria. All

  3. A Simplified Chromatographic Approach to Purify Commercially Available Bovine Submaxillary Mucins (BSM)

    DEFF Research Database (Denmark)

    Madsen, Jan Busk; Pakkanen, Kirsi I.; Duelund, Lars

    2015-01-01

    content and homogeneously distributed size, and in a high yield of 43% from BSM as received from the manufacturer. The purity and composition of commercially acquired BSM were assessed by sodium dodecyl sulfate polyacrylamide gel electrophoresis (SDS-PAGE) and mass spectrometry, which verified that BSA...

  4. A benchmark study of commercially available copper nanoparticle inks for application in organic electronic devices

    NARCIS (Netherlands)

    Polino, G.; Abbel, R.; Shanmugam, S.; Bex, G.J.P.; Hendriks, R.; Brunetti, F.; Di Carlo, A.; Andriessen, R.; Galagan, Y.

    2016-01-01

    A set of three commercial copper nanoparticle based inkjet inks has been benchmarked with respect to their potential to form conducting printed structures for future applications in organic electronic devices. Significant differences were observed in terms of jetting properties, spreading behaviour

  5. Specificity and sensitivity of commercially available assays for glucagon-like peptide-1 (GLP-1)

    DEFF Research Database (Denmark)

    Bak, Monika Judyta; Albrechtsen, Nicolai Jacob Wewer; Pedersen, Jens

    2014-01-01

    assessed with 3 commercial kits. RESULTS: The USCN LIFE assay detected none of the GLP-1 isoforms. The active GLP-1 ELISAs from Millipore and DRG seemed identical and were specific for intact GLP-1 in buffer and plasma. The Meso Scale Discovery Total GLP-1 kit detected all six GLP-1 isoforms, although...

  6. Bioequivalence Studies of a Reformulated Dutasteride and Tamsulosin Hydrochloride Combination Capsule and a Commercially Available Formulation.

    Science.gov (United States)

    Kurczewski, Renee; Bowen, Chet; Collins, David; Zhu, John; Serbest, Gulyeter; Manyak, Michael

    2017-09-01

    A dutasteride 0.5 mg and tamsulosin hydrochloride 0.4 mg combination (DTC) capsule (Duodart ® ) was reformulated to reduce the capsule size and enhance product stability. Bioequivalence of the reformulated DTC capsule with the commercial formulation was evaluated in 2 single-dose, open-label, randomized, 2-way crossover studies in healthy adult male volunteers. Subjects in a fasted or fed state received a single oral dose of either the reformulated DTC or the commercial formulation followed by a 28-day washout period between treatments. Blood samples were taken predose and up to 72 hours postdose for pharmacokinetic (PK) analysis of dutasteride and tamsulosin serum concentrations. From the serum concentration-vs-time data, a noncompartmental method was used to calculate the maximum observed serum concentration (C max ) and area under the serum concentration-time curve (AUC 0-t ) for dutasteride and tamsulosin, and AUC 0-∞ for tamsulosin. The 90% confidence intervals for the ratios of the C max and AUC 0-t (for dutasteride and tamsulosin) and for AUC 0-∞ (for tamsulosin) were all completely contained within the range of 80% to 125%; therefore, the reformulated DTC capsule is bioequivalent to the commercial formulation under both fed and fasted states. © 2017, The American College of Clinical Pharmacology.

  7. A study of commercially-available polyethylene terephthalate (PET) and polycarbonate as nuclear track detector materials

    Science.gov (United States)

    Espinosa, G.; Golzarri, J. I.; Vazquez-Lopez, C.; Trejo, R.; Lopez, K.; Rickards, J.

    2014-07-01

    In the study of the sensitivity of materials to be used as nuclear track detectors, it was found that commercial polyethylene terephthalate (PET) from Ciel® water bottles, commercial roof cover polycarbonate, and recycled packaging strips (recycled PET), can be used as nuclear track detectors. These three commercial materials present nuclear tracks when bombarded by 2.27 MeV nitrogen ions produced in a Pelletron particle accelerator, and by fission fragments from a 252Cf source (79.4 and 103.8 MeV), after a chemical etching with a 6.25M KOH solution, or with a 6.25M KOH solution with 20% methanol, both solutions at 60±1°C. As an example, the nitrogen ions deposit approximately 1 keV/nm in the form of ionization and excitation at the surface of PET, as calculated using the SRIM code. The fission fragments deposit up to 9 keV/nm at the surface, in both cases generating sufficient free radicals to initiate the track formation process. However, 5 MeV alpha particles, typical of radon (222Rn) emissions, deposit only 0.12 keV/nm, do not present tracks after the chemical etching process. This valuable information could be very useful for further studies of new materials in nuclear track methodology.

  8. Protective and antifungal properties of Nanodisk-Amphotericin B over commercially available Amphotericin B

    Directory of Open Access Journals (Sweden)

    Do-Yeon Cho

    2017-03-01

    Full Text Available Objective: Amphotericin B (AMB, a potent antifungal agent, has been employed as topical and systemic therapy for sinonasal fungal infections. A novel formulation of nanodisc (ND containing super aggregated AMB (ND-AMB for the treatment of fungal infections has been recently developed to provide greater protection from AMB toxicity than current, clinically approved lipid-based formulations. The objective of the current study was to evaluate the safety and potency of ND-AMB for sinonasal delivery using an in vitro model. Methods: Human sinonasal tissue was harvested during endoscopic sinus surgery and grown at air–liquid interface until well-differentiated. Cultures were exposed to ND-AMB vs AMB and changes in K+ permeability and resistance were measured and recorded via Ussing chamber assay. Ciliary beat frequency (CBF was analyzed in parallel as well as cytotoxic assay. Potency was assessed using real-time PCR measurement of the Aspergillus fumigatus 18S rRNA. Results: Ussing chamber studies revealed K+ currents that increased rapidly within 30 s of adding AMB (10 μg/mL to the apical side, indicating apical membranes had become permeable to K+ ions. In contrast, negligible induction of K+ current was obtained following addition of ND-AMB [AMB = (107.7 ± 15.9 μA/cm2 AMB vs ND-AMB = (2.3 ± 0.7 μA/cm2 ND-AMB; P = 0.005]. ND-AMB also protected nasal epithelial cells from cytotoxicity of AMB (P < 0.05. There was no difference in ciliary beat frequency between the two groups (P = 0.96. The expression of A. fumigatus 18S rRNA with exposure of lower dose of ND-AMB was significantly lower compared to that with AMB (P < 0.05. Conclusions: Data from the present study suggests ND-AMB protects human nasal epithelia membranes from AMB toxicity by protecting against apical cell K+ permeability while maintaining uncompromised antifungal property compared to AMB. ND-AMB could provide

  9. A cross-sectional ecological analysis of international and sub-national health inequalities in commercial geospatial resource availability.

    Science.gov (United States)

    Dotse-Gborgbortsi, Winfred; Wardrop, Nicola; Adewole, Ademola; Thomas, Mair L H; Wright, Jim

    2018-05-23

    Commercial geospatial data resources are frequently used to understand healthcare utilisation. Although there is widespread evidence of a digital divide for other digital resources and infra-structure, it is unclear how commercial geospatial data resources are distributed relative to health need. To examine the distribution of commercial geospatial data resources relative to health needs, we assembled coverage and quality metrics for commercial geocoding, neighbourhood characterisation, and travel time calculation resources for 183 countries. We developed a country-level, composite index of commercial geospatial data quality/availability and examined its distribution relative to age-standardised all-cause and cause specific (for three main causes of death) mortality using two inequality metrics, the slope index of inequality and relative concentration index. In two sub-national case studies, we also examined geocoding success rates versus area deprivation by district in Eastern Region, Ghana and Lagos State, Nigeria. Internationally, commercial geospatial data resources were inversely related to all-cause mortality. This relationship was more pronounced when examining mortality due to communicable diseases. Commercial geospatial data resources for calculating patient travel times were more equitably distributed relative to health need than resources for characterising neighbourhoods or geocoding patient addresses. Countries such as South Africa have comparatively high commercial geospatial data availability despite high mortality, whilst countries such as South Korea have comparatively low data availability and low mortality. Sub-nationally, evidence was mixed as to whether geocoding success was lowest in more deprived districts. To our knowledge, this is the first global analysis of commercial geospatial data resources in relation to health outcomes. In countries such as South Africa where there is high mortality but also comparatively rich commercial geospatial

  10. Biomass availability and commercialization trend analysis in China. A marketing study

    International Nuclear Information System (INIS)

    2000-10-01

    Among the different energy sources utilized in China, biomass energy takes a very important part. The importance of the biomass energy can be proved particularly in the rural area. In the period 1991 to 1995 the average consumption of bio-energy represented about 40% of the total rural energy consumption and about 70% of rural household energy consumption. The annual bio-energy consumption is more than 220 Mtce. According to prediction, all kinds of biomass fuels produced by new technology will take 40% of the total energy consumption all over the world at the middle of next century. In future decades, R and D for new technologies of producing all kinds of biomass energies as substitute fuels will be extremely important to China. The biomass energy resources in China mainly come from 4 sources: (1)The residues from agriculture and forestry processing such us straw, stalk, wood residues, high concentrated organic effluents from the agriculture products processing, etc.; (2) Firewood; (3) Human and animal excreta; and (4) Urban household solid wastes. The utilization technology of biomass energy can be generally classified as (a) The direct burn technology, which refers the method and equipment using crop straws and firewood as fuels through direct burning; (b) Physical conversion technology, which includes gasification technology by physical method - mainly heating and relevant equipment; (c) Biological conversion technology, which refers technology and equipment converting and gasifying the biomass through biological method - mainly anaerobic biodegradation; (d) Liquefaction technology; and (e) Conversion technology for solid waste. Chinese government has been giving great attention to the development and utilization of biomass energy. However, at present the bio-energy as one of the most important energy resources, its development and commercialized utilization are just at beginning stage. The basic conditions composing a market and commercialization environment

  11. Garlic, onions and cardiovascular risk factors. A review of the evidence from human experiments with emphasis on commercially available preparations

    NARCIS (Netherlands)

    Kleijnen, J.; Knipschild, P.; ter Riet, G.

    1989-01-01

    1. Claims for beneficial effects on cholesterol levels, fibrinolytic activity, and platelet aggregation are attributed both to fresh garlic and onions (or their extracts) and to commercially available preparations. 2. Regarding fresh garlic, the claims have been confirmed, but so far only at very

  12. Profits, Commercial Food Supplier Involvement, and School Vending Machine Snack Food Availability: Implications for Implementing the New Competitive Foods Rule

    Science.gov (United States)

    Terry-McElrath, Yvonne M.; Hood, Nancy E.; Colabianchi, Natalie; O'Malley, Patrick M.; Johnston, Lloyd D.

    2014-01-01

    Background: The 2013-2014 school year involved preparation for implementing the new US Department of Agriculture (USDA) competitive foods nutrition standards. An awareness of associations between commercial supplier involvement, food vending practices, and food vending item availability may assist schools in preparing for the new standards.…

  13. A commercially available IgE-based test for food allergy gives inconsistent results in healthy ponies

    NARCIS (Netherlands)

    Dupont, S; De Spiegeleer, A; Liu, D J X; Lefère, L; van Doorn, D A; Hesta, M

    2014-01-01

    REASONS FOR PERFORMING STUDY: Commercial IgE-based tests are available for diagnosis of food allergies and are commonly used in equine practice. However, these tests have been proven unreliable as a screening method in humans and other species, but not critically evaluated in equines. Therefore, a

  14. Efficacy of four commercially available heartworm preventive products against the JYD-34 laboratory strain of Dirofilaria immitis

    OpenAIRE

    Blagburn, Byron L.; Arther, Robert G.; Dillon, Allen R.; Butler, Jamie M.; Bowles, Joy V.; von Simson, Cristiano; Zolynas, Robert

    2016-01-01

    Background Heartworm disease in dogs can be severe and life threatening. Resistance to available heartworm preventives was considered among potential causes of increased reports of failed heartworm prevention in dogs. The objective of the present study was to compare the efficacy of four commercially available heartworm disease preventives against the JYD-34 strain of D. immitis. Methods Forty laboratory-reared dogs approximately 6 months old were used. Each dog was infected with fifty, third...

  15. Study of Commercially Available Lobelia chinensis Products Using Bar-HRM Technology.

    Science.gov (United States)

    Sun, Wei; Yan, Song; Li, Jingjian; Xiong, Chao; Shi, Yuhua; Wu, Lan; Xiang, Li; Deng, Bo; Ma, Wei; Chen, Shilin

    2017-01-01

    There is an unmet need for herbal medicine identification using a fast, sensitive, and easy-to-use method that does not require complex infrastructure and well-trained technicians. For instance, the detection of adulterants in Lobelia chinensis herbal product has been challenging, since current detection technologies are not effective due to their own limits. High Resolution Melting (HRM) has emerged as a powerful new technology for clinical diagnosis, research in the food industry and in plant molecular biology, and this method has already highlighted the complexity of species identification. In this study, we developed a method of species specific detection of L. chinensis using HRM analysis combined with internal transcribed spacer 2. We then applied this method to commercial products purporting to contain L . chinensis . Our results demonstrated that HRM can differentiate L. chinensis from six common adulterants. HRM was proven to be a fast and accurate technique for testing the authenticity of L. chinensis in herbal products. Based on these results, a HRM approach for herbal authentication is provided.

  16. Wearable Devices in Medical Internet of Things: Scientific Research and Commercially Available Devices.

    Science.gov (United States)

    Haghi, Mostafa; Thurow, Kerstin; Stoll, Regina

    2017-01-01

    Wearable devices are currently at the heart of just about every discussion related to the Internet of Things. The requirement for self-health monitoring and preventive medicine is increasing due to the projected dramatic increase in the number of elderly people until 2020. Developed technologies are truly able to reduce the overall costs for prevention and monitoring. This is possible by constantly monitoring health indicators in various areas, and in particular, wearable devices are considered to carry this task out. These wearable devices and mobile apps now have been integrated with telemedicine and telehealth efficiently, to structure the medical Internet of Things. This paper reviews wearable health care devices both in scientific papers and commercial efforts. MIoT is demonstrated through a defined architecture design, including hardware and software dealing with wearable devices, sensors, smart phones, medical application, and medical station analyzers for further diagnosis and data storage. Wearables, with the help of improved technology have been developed greatly and are considered reliable tools for long-term health monitoring systems. These are applied in the observation of a large variety of health monitoring indicators in the environment, vital signs, and fitness. Wearable devices are now used for a wide range of healthcare observation. One of the most important elements essential in data collection is the sensor. During recent years with improvement in semiconductor technology, sensors have made investigation of a full range of parameters closer to realization.

  17. An evaluation of three commercially available metal artifact reduction methods for CT imaging

    International Nuclear Information System (INIS)

    Huang, Jessie Y; Kerns, James R; Balter, Peter A; Followill, David S; Mirkovic, Dragan; Howell, Rebecca M; Kry, Stephen F; Nute, Jessica L; Liu, Xinming; Stingo, Francesco C

    2015-01-01

    Three commercial metal artifact reduction methods were evaluated for use in computed tomography (CT) imaging in the presence of clinically realistic metal implants: Philips O-MAR, GE’s monochromatic gemstone spectral imaging (GSI) using dual-energy CT, and GSI monochromatic imaging with metal artifact reduction software applied (MARs). Each method was evaluated according to CT number accuracy, metal size accuracy, and streak artifact severity reduction by using several phantoms, including three anthropomorphic phantoms containing metal implants (hip prosthesis, dental fillings and spinal fixation rods). All three methods showed varying degrees of success for the hip prosthesis and spinal fixation rod cases, while none were particularly beneficial for dental artifacts. Limitations of the methods were also observed. MARs underestimated the size of metal implants and introduced new artifacts in imaging planes beyond the metal implant when applied to dental artifacts, and both the O-MAR and MARs algorithms induced artifacts for spinal fixation rods in a thoracic phantom. Our findings suggest that all three artifact mitigation methods may benefit patients with metal implants, though they should be used with caution in certain scenarios. (paper)

  18. Comparative Assessment of Anti-HLA Antibodies Using Two Commercially Available Luminex-Based Assays.

    Science.gov (United States)

    Clerkin, Kevin J; See, Sarah B; Farr, Maryjane A; Restaino, Susan W; Serban, Geo; Latif, Farhana; Li, Lingzhi; Colombo, Paolo C; Vlad, George; Ray, Bryan; Vasilescu, Elena R; Zorn, Emmanuel

    2017-11-01

    Allospecific anti-HLA antibodies (Abs) are associated with rejection of solid organ grafts. The 2 main kits to detect anti-HLA Ab in patient serum are commercialized by Immucor and One Lambda/ThermoFisher. We sought to compare the performance of both platforms. Background-adjusted mean fluorescence intensity (MFI) values were used from both platforms to compare sera collected from 125 pretransplant and posttransplant heart and lung transplant recipients. Most HLA class I (94.5%) and HLA class II (89%) Abs with moderate to high MFI titer (≥4000) were detected by both assays. A modest correlation was observed between MFI values obtained from the 2 assays for both class I ( r = 0.3, r 2 = 0.09, P < 0.0001) and class II Ab ( r = 0.707, r 2 = 0.5, P < 0.0001). Both assays detected anti-class I and II Ab that the other did not; however, no specific HLA allele was detected preferentially by either of the 2 assays. For a limited number of discrepant sera, dilution resulted in comparable reactivity profiles between the 2 platforms. Immucor and One Lambda/ThermoFisher assays have a similar, albeit nonidentical, ability to detect anti-HLA Ab. Although the correlation between the assays was present, significant variances exist, some of which can be explained by a dilution-sensitive "prozone" effect.

  19. Evaluation of free radical scavenging activity of tea infusion of commercial tea products available in uae

    International Nuclear Information System (INIS)

    Nessa, F.; Khan, S.A.

    2014-01-01

    In the present study, twenty four commercial tea samples were assayed to determine their free radical scavenging activity and polyphenolic contents based on the brewing/infusing period. Tea samples were infused/brewed in 200 mL boiled water at 120 degree C for 1, 2 and 5 min, respectively. The radical scavenging activities of tea infusion/brewing were measured using 1,1-diphenyl-2-picrylhydrazyl radical (DPPH) assay method. The results were ranged from 67.81-90.51% for black tea bags, 90.37-94.51% for green tea bags, 24.66-92.25% for black tea powder, 16.08-93.06% for green tea powder and 32.90- 45.54% for Camomile herbal infusion. The results showed that 1 or 2 min black tea bags infusion exhibited highest radical scavenging activity than 5 min infusion. Antioxidant activities of tea powders were variable with the amount of tea powder. It was observed that antioxidant activity increased with increasing boiling time for smaller amount of sample. In contrary, shorter boiling time was better for larger amount of sample. The polyphenol contents of tea infusion were determined and the results were expressed as milligram quercetin equivalent/200 mL of tea infusion. The polyphenol content was increased with increased brewing period. In contrary, brewing for longer time rendered extract less antiradical activity. This study suggests that infusing tea bag for 1 or 2 min is sufficient for getting infusion with maximum radical scavenging activity and in case of tea powder, shorter boiling time is better for larger amount of powder or small amount of powder should be boiled for minimum 5 min for rendering extract with maximum radical scavenging activity. (author)

  20. Quality assurance in proton beam therapy using a plastic scintillator and a commercially available digital camera.

    Science.gov (United States)

    Almurayshid, Mansour; Helo, Yusuf; Kacperek, Andrzej; Griffiths, Jennifer; Hebden, Jem; Gibson, Adam

    2017-09-01

    In this article, we evaluate a plastic scintillation detector system for quality assurance in proton therapy using a BC-408 plastic scintillator, a commercial camera, and a computer. The basic characteristics of the system were assessed in a series of proton irradiations. The reproducibility and response to changes of dose, dose-rate, and proton energy were determined. Photographs of the scintillation light distributions were acquired, and compared with Geant4 Monte Carlo simulations and with depth-dose curves measured with an ionization chamber. A quenching effect was observed at the Bragg peak of the 60 MeV proton beam where less light was produced than expected. We developed an approach using Birks equation to correct for this quenching. We simulated the linear energy transfer (LET) as a function of depth in Geant4 and found Birks constant by comparing the calculated LET and measured scintillation light distribution. We then used the derived value of Birks constant to correct the measured scintillation light distribution for quenching using Geant4. The corrected light output from the scintillator increased linearly with dose. The system is stable and offers short-term reproducibility to within 0.80%. No dose rate dependency was observed in this work. This approach offers an effective way to correct for quenching, and could provide a method for rapid, convenient, routine quality assurance for clinical proton beams. Furthermore, the system has the advantage of providing 2D visualization of individual radiation fields, with potential application for quality assurance of complex, time-varying fields. © 2017 The Authors. Journal of Applied Clinical Medical Physics published by Wiley Periodicals, Inc. on behalf of American Association of Physicists in Medicine.

  1. Practical Tips for Construction of Custom Peptide Libraries and Affinity Selection by Using Commercially Available Phage Display Cloning Systems

    Directory of Open Access Journals (Sweden)

    Keisuke Fukunaga

    2012-01-01

    Full Text Available Phage display technology is undoubtedly a powerful tool for affinity selection of target-specific peptide. Commercially available premade phage libraries allow us to take screening in the easiest way. On the other hand, construction of a custom phage library seems to be inaccessible, because several practical tips are absent in instructions. This paper focuses on what should be born in mind for beginners using commercially available cloning kits (Ph.D. with type 3 vector and T7Select systems for M13 and T7 phage, respectively. In the M13 system, Pro or a basic amino acid (especially, Arg should be avoided at the N-terminus of peptide fused to gp3. In both systems, peptides containing odd number(s of Cys should be designed with caution. Also, DNA sequencing of a constructed library before biopanning is highly recommended for finding unexpected bias.

  2. Three-Input Single-Output Voltage-Mode Multifunction Filter with Electronic Controllability Based on Single Commercially Available IC

    Directory of Open Access Journals (Sweden)

    Supachai Klungtong

    2017-01-01

    Full Text Available This paper presents a second-order voltage-mode filter with three inputs and single-output voltage using single commercially available IC, one resistor, and two capacitors. The used commercially available IC, called LT1228, is manufactured by Linear Technology Corporation. The proposed filter is based on parallel RLC circuit. The filter provides five output filter responses, namely, band-pass (BP, band-reject (BR, low-pass (LP, high-pass (HP, and all-pass (AP functions. The selection of each filter response can be done without the requirement of active and passive component matching condition. Furthermore, the natural frequency and quality factor are electronically controlled. Besides, the nonideal case is also investigated. The output voltage node exhibits low impedance. The experimental results can validate the theoretical analyses.

  3. Performance of the Locally Made Disposable 10-gram Semmes-Weinstein Monofilament Compared to the Commercially Available Monofilament

    Directory of Open Access Journals (Sweden)

    Danu Prommin, Ph.D.

    2018-01-01

    Full Text Available Objective: The aim of this study was to find a technique to make a disposable monofilament which is accurate and affordable for Thailand context. A prototype of local made monofilament was developed and tested with the calibrated universal machine test to evaluate its performance compared with the commercial monofilament. Effect of the uncontrolled humidity condition on the performance of the commercial monofilament was also studied. Methods: Review of literatures showed no published specifications of the monofilament. The investigators set the concepts that materials must be locally available and affordable. Also, the unit cost must be affordable for primary care units in Thailand. Monofilament’s fabrication technique was developed and the accuracy test of monofilament force was performed and compared with the commercially available monofilament. Results: The specification of locally made disposable 10-gram Semmes-Weinstein monofilament was identified. The force of the monofilaments developed was in an acceptable range for a standard clinical practice and comparable to the commercially available monofilament. From the study, the effect of Thailand’s humidity conditions can deteriorate the performance of the monofilament. The investigators decided to use a disposable monofilament one to ensure its hygiene and accuracy. Conclusion: The local made disposable 10-gram Semmes-Weinstein monofilament was developed. The material is available and affordable for Thailand context. The accuracy of the monofilament’s force was measured by a calibrated testing apparatus. Availability, durability, and cost are important issues to be concerned for medical tools that have been recommended to use worldwide. The result from this study could be applied to other countries that have similar conditions as Thailand.

  4. In vitro fracture resistance of three commercially available zirconia crowns for primary molars.

    Science.gov (United States)

    Townsend, Janice A; Knoell, Patrick; Yu, Qingzhao; Zhang, Jian-Feng; Wang, Yapin; Zhu, Han; Beattie, Sean; Xu, Xiaoming

    2014-01-01

    The purpose of this study was to measure the fracture resistance of primary mandibular first molar zirconia crowns from three different manufacturers-EZ Pedo (EZP), NuSmile (NSZ), and Kinder Krowns (KK)-and compare it with the thickness of the zirconia crowns and the measured fracture resistance of preveneered stainless steel crowns (SSCs). The thickness of 20 zirconia crowns from three manufacturers were measured. The mean force required to fracture the crowns was determined. Preveneered NuSmile (NSW) SSCs were tested as a control. EZP crowns were significantly thicker in three of the six measured locations. The force required to fracture the EZP crown was significantly higher than that required for NSZ and KK. There was a positive correlation between fracture resistance and crown thickness in the mesial, distal, mesioocclusal, and distoocclusal dimensions. None of the zirconia crowns proved to be as resistant to fracture as the preveneered SSCs. Statistically significant differences were found among the forces required to fracture zirconia crowns by three different manufacturers. The increase in force correlated with crown thickness. The forces required to fracture the preveneered stainless steel crowns were greater than the forces required to fracture all manufacturers' zirconia crowns.

  5. Phantom evaluation of a commercially available three modality image guided radiation therapy system

    International Nuclear Information System (INIS)

    Ploquin, Nicolas; Rangel, Alejandra; Dunscombe, Peter

    2008-01-01

    The authors describe a detailed evaluation of the capabilities of imaging and image registration systems available with Varian linear accelerators for image guided radiation therapy (IGRT). Specifically, they present modulation transfer function curves for megavoltage planar, kilovoltage (kV) planar, and cone beam computed tomography imaging systems and compare these with conventional computed tomography. While kV planar imaging displayed the highest spatial resolution, all IGRT imaging techniques were assessed as adequate for their intended purpose. They have also characterized the image registration software available for use in conjunction with these imaging systems through a comprehensive phantom study involving translations in three orthogonal directions. All combinations of imaging systems and image registration software were found to be accurate, although the planar kV imaging system with automatic registration was generally superior, with both accuracy and precision of the order of 1 mm, under the conditions tested. Based on their phantom study, the attainable accuracy for rigid body translations using any of the features available with Varian equipment will more likely be limited by the resolution of the couch readouts than by inherent limitations in the imaging systems and image registration software. Overall, the accuracy and precision of currently available IGRT technology exceed published experience with the accuracy and precision of contouring for planning.

  6. 78 FR 38683 - Availability of Guidance: Establishments Guidance for the Selection of a Commercial or Private...

    Science.gov (United States)

    2013-06-27

    ... with regard to the risk of contamination that could spread from an on-site laboratory to manufacturing... DEPARTMENT OF AGRICULTURE Food Safety and Inspection Service [Docket No. FSIS-2011-0033... Testing Laboratory AGENCY: Food Safety and Inspection Service, USDA. ACTION: Notice of availability...

  7. 76 FR 12403 - Office of Commercial Space Transportation; Notice of Availability of the Finding of No...

    Science.gov (United States)

    2011-03-07

    ... Transportation; Notice of Availability of the Finding of No Significant Impact (FONSI) for Actions Related to the Renewal of a Launch Operator License for Delta II Expendable Launch Vehicles at Cape Canaveral Air Force Station, Florida AGENCY: Federal Aviation Administration (FAA), Department of Transportation. ACTION...

  8. A specialist toxicity database (TRACE) is more effective than its larger, commercially available counterparts

    NARCIS (Netherlands)

    Anderson, C.A.; Copestake, P.T.; Robinson, L.

    2000-01-01

    The retrieval precision and recall of a specialist bibliographic toxicity database (TRACE) and a range of widely available bibliographic databases used to identify toxicity papers were compared. The analysis indicated that the larger size and resources of the major bibliographic databases did not,

  9. Availability of heavy metals (Cd, Pb, And Cr) in agriculture from commercial fertilizers.

    Science.gov (United States)

    Nacke, H; Gonçalves, A C; Schwantes, D; Nava, I A; Strey, L; Coelho, G F

    2013-05-01

    The purpose of this study was to investigate the availability of the heavy metals cadmium (Cd), lead (Pb), and chromium (Cr) to soil and maize plants fertilized with different sources and doses of zinc (Zn) in a Rhodic Eutrudox soil. For that purpose, concentrations of Cd, Pb, and Cr were evaluated in leaf tissue and grains of maize plants and in 0-20 and 20-40 cm soil layers after fertilization with four doses of Zn from eight different sources of fertilizer. There was no accumulation of Cd, Pb, and Cr in maize grain and Cd and Cr in leaf tissue of the plants; nevertheless, there was accumulation of Pb in leaf tissue, showing its availability throughout different sources of Zn and consequent uptake by plants. Regarding the soil, it was observed that fertilizer from the different sources made Cd, Pb, and Cr available at increasing amounts proportional to increased Zn doses. Under experimental conditions, fertilization with Zn increased concentrations of heavy metals Cd, Pb and Cr in soil, further highlighting the importance of conducting more studies related to the application of mineral fertilizers for micronutrient supply and the availability of heavy metals.

  10. Commercially Available Low Probability of Intercept Radars and Non-Cooperative ELINT Receiver Capabilities

    Science.gov (United States)

    2014-09-01

    3D Antenna Gain 0 dB Azimuth Accuracy 20°/quadrant 52 51. ELT/750 Receiver Figure 51: ELT/750 Receiver/processor...71]) The Itata ELINT system has been developed by Desarrollo de Tecnologia y Sistemas (DTS) Ltd. and is a high-sensitivity electronic... 3D Long Range Surveillance Radar. [Online]. Available: https://www.thalesgroup.com/en/worldwide/defence/smart-l- 3d - long-range-surveillance-radar

  11. Methods and results of implementing a commercially available videotaped health physics training program in a multi-disciplined DOE facility

    International Nuclear Information System (INIS)

    O'Neal, B.L.

    1979-01-01

    Sandia, a prime contractor for DOE, is a multi-disciplined research and development laboratory. Its various activities include the operations of two nuclear reactors, several multi-kilocurie gamma irradiation facilities, a transuranic hot cell facility, various and numerous particle accelerators and x-ray generators, and many other areas involving employees working with or around radioactive materials or radiation producing machines. Since March 1979, Sandia has conducted a formalized basic radiation safety training program using a commercially available videotaped training package. The videotapes are generic in nature and are accompanied with hard copy text material, vu-graphs, quizzes, and an instructor's guide. Sandia's overall training program and the methods, results, and problem areas of implementing an off the shelf, commercially available videotaped training program are described. Results are summarized using an instructor/course/student evaluation form

  12. Currently Commercially Available Chemical Sensors Employed for Detection of Volatile Organic Compounds in Outdoor and Indoor Air

    OpenAIRE

    Bartosz Szulczyński; Jacek Gębicki

    2017-01-01

    The paper presents principle of operation and design of the most popular chemical sensors for measurement of volatile organic compounds (VOCs) in outdoor and indoor air. It describes the sensors for evaluation of explosion risk including pellistors and IR-absorption sensors as well as the sensors for detection of toxic compounds such as electrochemical (amperometric), photoionization and semiconductor with solid electrolyte ones. Commercially available sensors for detection of VOCs and their ...

  13. An investigation on physical quality control parameters of dietary supplements tablets commercially available on the Kingdom of Saudi Arabia

    OpenAIRE

    H M Maswadeh; A N Al-Jarbou

    2011-01-01

    Summary: The goal of this study was to investigate the physical quality control parameters of dietary supplements tablets commercially available on the Kingdom of Saudi Arabia by using weight variation, friability and disintegration tests. The impact of immersion medium pH and the use of disk during disintegration test of dietary supplements as well as a price comparison with respect to quality were investigated. All products were found to fulfill the USP >2091< weight variation and >...

  14. Oral bioaccessibility of toxic and essential elements in raw and cooked commercial seafood species available in European markets

    DEFF Research Database (Denmark)

    Alves, Ricardo N.; Maulvault, Ana L.; Barbosa, Vera L.

    2017-01-01

    The oral bioaccessibility of several essential and toxic elements was investigated in raw and cooked commercially available seafood species from European markets. Bioaccessibility varied between seafood species and elements. Methylmercury bioaccessibility varied between 10 (octopus) and 60...... % (monkfish). Arsenic (> 64%) was the toxic element showing the highest bioaccessibility. Concerning essential elements bioaccessibility in raw seafood, selenium (73 %) and iodine (71 %) revealed the highest percentages. The bioaccessibility of elements in steamed products increased or decreased according...

  15. Performance evaluation of a commercially available heat flow calorimeter and applicability assessment for safeguarding special nuclear materials

    International Nuclear Information System (INIS)

    Bracken, D.S.; Biddle, R.; Rudy, C.

    1998-01-01

    The performance characteristics of a commercially available heat-flow calorimeter will be presented. The heat-flow sensors within the calorimeter are based on thermopile technology with a vendor-quoted sensitivity of 150 microV/mW. The calorimeter is a full-twin design to compensate for ambient temperature fluctuations. The efficacy of temperature fluctuation compensations will also be detailed. Finally, an assessment of design applicability to special nuclear materials control and accountability and safeguarding will be presented

  16. Quantifying the foodscape: A systematic review and meta-analysis of the validity of commercially available business data

    OpenAIRE

    Lebel, Alexandre; Daepp, Madeleine I. G.; Block, Jason P.; Walker, Renée; Lalonde, Benoît; Kestens, Yan; Subramanian, S. V.

    2017-01-01

    This paper reviews studies of the validity of commercially available business (CAB) data on food establishments (?the foodscape?), offering a meta-analysis of characteristics associated with CAB quality and a case study evaluating the performance of commonly-used validity indicators describing the foodscape. Existing validation studies report a broad range in CAB data quality, although most studies conclude that CAB quality is ?moderate? to ?substantial?. We conclude that current studies may ...

  17. Effect of simulated chairside grinding procedures using commercially available abrasive agents on the surface properties of zirconia

    OpenAIRE

    Sandhu, Ramandeep; Kheur, Mohit; Kheur, Supriya

    2017-01-01

    Aim: The aim of the present study was to assess the change in physical properties (surface roughness, surface hardness and phase transformation) after surface grinding of zirconia by using three commercially available abrasives. Materials and Methods: Thirty sintered zirconia specimens were prepared and divided into three groups namely Group M (grinded using Mani Dia diamond bur standard grit), Group T (grinded using Tri Hawk diamond bur coarse grit) and Group P (grinded using Predator car...

  18. Commercial-sector energy-consumption data-base-development project. Volume II. Survey of available energy use data

    Energy Technology Data Exchange (ETDEWEB)

    None

    1978-04-01

    A compilation of data on energy consumption in the commercial sector that have been published elsewhere is presented. Readily available information was collected on the structural, equipment, and energy use characteristics of the following: store and other mercantile buildings; warehouses; finance, insurance, real estate, and services industries; schools and colleges; hospitals and nursing homes; and government buildings. Energy data are shown in terms of Btu/ft/sup 2/. (MCW)

  19. Assessing Commercially Available Personal Health Records for Home Health: Recommendations for Design.

    Science.gov (United States)

    Kneale, Laura; Choi, Yong; Demiris, George

    2016-01-01

    Home health nurses and clients experience unmet information needs when transitioning from hospital to home health. Personal health records (PHRs) support consumer-centered information management activities. Previous work has assessed PHRs associated with healthcare providers, but these systems leave home health nurses unable to access necessary information. To evaluate the ability of publically available PHRs to accept, manage, and share information from a home health case study. Two researchers accessed the publically available PHRs on myPHR.com, and attempted to enter, manage, and share the case study data. We qualitatively described the PHR features, and identified gaps between the case study information and PHR functionality. Eighteen PHRs were identified in our initial search. Seven systems met our inclusion criteria, and are included in this review. The PHRs were able to accept basic medical information. Gaps occurred when entering, managing, and/or sharing data from the acute care and home health episodes. The PHRs that were reviewed were unable to effectively manage the case study information. Therefore, increasing consumer health literacy through these systems may be difficult. The PHRs that we reviewed were also unable to electronically share their data. The gap between the existing functionality and the information needs from the case study may make these PHRs difficult to use for home health environments. Additional work is needed to increase the functionality of the PHR systems to better fit the data needs of home health clients.

  20. Quantitative immunohistochemistry by measuring cumulative signal strength using commercially available software photoshop and matlab.

    Science.gov (United States)

    Matkowskyj, K A; Schonfeld, D; Benya, R V

    2000-02-01

    Currently available techniques for performing quantitative immunohistochemistry (Q-IHC) rely upon pixel-counting algorithms and therefore cannot provide information as to the absolute amount of chromogen present. We describe a novel algorithm for true Q-IHC based on calculating the cumulative signal strength, or energy, of the digital file representing any portion of an image. This algorithm involves subtracting the energy of the digital file encoding the control image (i.e., not exposed to antibody) from that of the experimental image (i.e., antibody-treated). In this manner, the absolute amount of antibody-specific chromogen per pixel can be determined for any cellular region or structure. (J Histochem Cytochem 48:303-311, 2000)

  1. PCR Based Detection of Genetically Modified Soy in Processed Foods Commercially Available in Saudi Arabia

    Directory of Open Access Journals (Sweden)

    Ibrahim Abdullah Alaraidh

    2009-06-01

    Full Text Available In this research, PCR (polymerase chain reaction technique was applied to detect the presence of GMO sold in the Saudi Arabian market. This method was applied to detect genetically modified soy (GM-soy in particular the roundup ready soy (RRS. To confirm the presence of soy, samples were first tested for the existence of the soy specific lectin gene.  A total of eighty samples were tested out of which two samples tested positive as GM-soy. Not surprisingly, the findings showed the existence of GM-soy in food products in Saudi. This supports the necessity of developing precise quantitative and qualitative ways for routine analyses and detection of GMO products in the Saudi Arabian market. With the discovery of GM products in the Saudi Arabian market it would be of no surprise that other Middle Eastern nations also knowingly or unknowingly import GM crops.

  2. Antioxidant capacity, phenolic acids and caffeine contents of some commercial coffees available on the Romanian market.

    Science.gov (United States)

    Trandafir, Ion; Nour, Violeta; Ionica, Mira Elena

    2013-03-01

    In the present study a simple and highly sensitive RP-HPLC method has been established for simultaneous determination of chlorogenic acid, caffeic acid, vanillic acid and caffeine in coffee samples. The method has been applied to eight different coffees available on the Romanian market which were previously analysed concerning the total polyphenols content and antioxidant capacity. Reduction of the DPPH radical was used to determine the antioxidant capacity of the coffee extracts while the total polyphenols content was determined by spectrophotometry (Folin Ciocalteu's method). The total polyphenols content ranged from 1.98 g GAE/100 g to 4.19 g GAE/100 g while the caffeine content ranged from 1.89 g/100 g to 3.05 g/100 g. A large variability was observed in chlorogenic acid content of the investigated coffee samples which ranged between 0.6 and 2.32 g/100 g.

  3. New portability for in situ gamma-ray spectrometry from commercially available equipment

    International Nuclear Information System (INIS)

    Stanford, N.; Laurenzo, E.L.; McCurdy, D.E.

    1984-01-01

    In situ gamma-ray spectrometry has been employed by the staff of the Yankee Atomic Environmental Laboratory on a routine basis for more than five years. The original in situ gamma-ray spectrometry methodology was adopted from the techniques developed at the DOE Environmental Measurements Laboratory (Beck, DeCampo, and Gogolak 1972). The system consisted of a 110 cm 3 Ge(Li) detector in the vertical configuration in conjunction with typical laboratory nuclear instrumentation, as well as a medium-sized desktop computer, printer and disk drive. The equipment was transported in a small van having a shock-mounted cabinet and gasoline generator as an electrical power source. Recent availability of miniaturized spectrometry systems and powerful portable computers has enabled the upgrading of the 1977 vintage equipment to a system which is truly portable, light weight, compact and more reliable. The system to be described utilizes a portable intrinsic germanium detector, a small, 4096 channel pulse height analyzer (MCA) with anscillary components and a 24K, Hewlett Packard HP-75 computer with a small tape drive. When the equipment is used in the field, the system has enough capability to acquire and store a full 4096 channel gamma-ray spectrum and calculate the soil concentrations (pCi/g) and/or external radiation exposure rates for the commonly found naturally occurring, long-lived atmospheric nuclear weapons testing and nuclear power plant radionuclides. Subsequent data transfer to a larger desktop computer via available interfacing at the laboratory enables a full peak search and a more extensive evaluation of the data in order to calculate the soil concentrations and/or external radiation exposure rates for a selected 25 radionuclides. Experiences from the first season of operation are discussed

  4. Evaluation of commercially available biodegradable tetracycline fiber therapy in chronic periodontitis

    Science.gov (United States)

    Sachdeva, Surinder; Agarwal, Vipin

    2011-01-01

    Background: Chronic periodontitis is an inflammatory disorder caused by dental plaque having mixed microbial flora. The different treatment modalities available to treat this disease are aimed at removal of micro-organisms from both hard and soft tissues. Systemic as well as local anti-microbial agents are helpful adjuncts in reducing microbes especially in inaccessible areas along with mechanical debridement therapy. Materials and Methods: The study was conducted in a split mouth design. Thirty-five patients having at least two non-adjacent sites in different quadrants with periodontal pockets ≥5 mm and with bleeding on probing at initial visit were selected. The selected sites were treated with both scaling and root planing plus tetracycline fibers or with scaling and root planing alone. Baseline and follow-up measurements included plaque index, gingival index, probing pocket depth, and clinical attachment level. Result: Both treatment modalities were affective in improving clinical parameters over three months’ observation period. The combined antimicrobial and mechanical debridement therapy has shown better results as compared with scaling and root planing alone. Conclusion: Application of tetracycline in modified collagen matrix following scaling and root planing might be beneficial in treatment of chronic periodontitis and improving periodontal parameters for 3-month duration. PMID:21976836

  5. In silico docking studies of aldose reductase inhibitory activity of commercially available flavonoids

    Directory of Open Access Journals (Sweden)

    Arumugam Madeswaran

    2012-12-01

    Full Text Available The primary objective of this study was to investigate the aldose reductase inhibitory activity of flavonoids using in silico docking studies. In this perspective, flavonoids like biochanin, butein, esculatin, fisetin and herbacetin were selected. Epalrestat, a known aldose reductase inhibitor was used as the standard. In silico docking studies were carried out using AutoDock 4.2, based on the Lamarckian genetic algorithm principle. The results showed that all the selected flavonoids showed binding energy ranging between -9.33 kcal/mol to -7.23 kcal/mol when compared with that of the standard (-8.73 kcal/mol. Inhibition constant (144.13 µM to 4.98 µM and intermolecular energy (-11.42 kcal/mol to -7.83 kcal/mol of the flavonoids also coincide with the binding energy. All the selected flavonoids contributed aldose reductase inhibitory activity because of its structural properties. These molecular docking analyses could lead to the further development of potent aldose reductase inhibitors for the treatment of diabetes.

  6. A commercially available immunoglobulin E-based test for food allergy gives inconsistent results in healthy ponies.

    Science.gov (United States)

    Dupont, S; De Spiegeleer, A; Liu, D J X; Lefère, L; van Doorn, D A; Hesta, M

    2016-01-01

    Commercial immunoglobulin E (IgE)-based tests are available for diagnosis of food allergies and are commonly used in equine practice. However, these tests have been proven unreliable as a screening method in man and other species, but not critically evaluated in equids. Therefore, a commercially available IgE-based test for horses was evaluated. To evaluate the consistency of the results obtained with a commercially available IgE-based test for food allergy diagnosis in ponies (Phase I) and to subject ponies to a provocation trial with the presumed allergens (Phase II). Allergen screening followed by experimental food provocation trials in healthy ponies. Blood samples of 17 healthy Shetland ponies were taken at 2 different time points, sent blinded to a commercial laboratory for screening of common food allergens and the results were evaluated for consistency (Phase I). Ponies that were positive for food allergens were consecutively challenged orally with each allergen separately for 14 days (Phase II). A washout period of one week was applied in ponies with multiple positive results. Clinical parameters and serum amyloid A were monitored during the provocation trial. Only 7/17 ponies were negative on the IgE-based test at the 2 time points, 3 had positive results twice but only one tested positive twice for the same food allergen. No abnormalities were noted during the provocation trials. This study demonstrated that this IgE-based test is not a reliable screening tool for food allergy in healthy equids. © 2015 EVJ Ltd.

  7. Computer-aided auscultation of murmurs in children: evaluation of commercially available software.

    Science.gov (United States)

    Lee, Cecilia; Rankin, Kathryn N; Zuo, Kevin J; Mackie, Andrew S

    2016-10-01

    Heart murmurs are common in children and may represent congenital or acquired cardiac pathology. Auscultation is challenging and many primary-care physicians lack the skill to differentiate innocent from pathologic murmurs. We sought to determine whether computer-aided auscultation (CardioscanTM) identifies which children require referral to a cardiologist. We consecutively enrolled children aged between 0 and 17 years with a murmur, innocent or pathologic, being evaluated in a tertiary-care cardiology clinic. Children being evaluated for the first time and patients with known cardiac pathology were eligible. We excluded children who had undergone cardiac surgery previously or were unable to sit still for auscultation. CardioscanTM auscultation was performed in a quiet room with the subject in the supine position. The sensitivity and specificity of a potentially pathologic murmur designation by CardioscanTM - that is, requiring referral - was determined using echocardiography as the reference standard. We enrolled 126 subjects (44% female) with a median age of 1.7 years, with 93 (74%) having cardiac pathology. The sensitivity and specificity of a potentially pathologic murmur determination by CardioscanTM for identification of cardiac pathology were 83.9 and 30.3%, respectively, versus 75.0 and 71.4%, respectively, when limited to subjects with a heart rate of 50-120 beats per minute. The combination of a CardioscanTM potentially pathologic murmur designation or an abnormal electrocardiogram improved sensitivity to 93.5%, with no haemodynamically significant lesions missed. Sensitivity of CardioscanTM when interpreted in conjunction with an abnormal electrocardiogram was high, although specificity was poor. Re-evaluation of computer-aided auscultation will remain necessary as advances in this technology become available.

  8. Currently Commercially Available Chemical Sensors Employed for Detection of Volatile Organic Compounds in Outdoor and Indoor Air

    Directory of Open Access Journals (Sweden)

    Bartosz Szulczyński

    2017-03-01

    Full Text Available The paper presents principle of operation and design of the most popular chemical sensors for measurement of volatile organic compounds (VOCs in outdoor and indoor air. It describes the sensors for evaluation of explosion risk including pellistors and IR-absorption sensors as well as the sensors for detection of toxic compounds such as electrochemical (amperometric, photoionization and semiconductor with solid electrolyte ones. Commercially available sensors for detection of VOCs and their metrological parameters—measurement range, limit of detection, measurement resolution, sensitivity and response time—were presented. Moreover, development trends and prospects of improvement of the metrological parameters of these sensors were highlighted.

  9. Comparison of newly developed anti-bone morphogenetic protein 4 llama-derived antibodies with commercially available BMP4 inhibitors.

    Science.gov (United States)

    Calpe, Silvia; Correia, Ana C P; Sancho-Serra, Maria Del Carmen; Krishnadath, Kausilia K

    2016-01-01

    Due to improved understanding of the role of bone morphogenetic protein 4 (BMP4) in an increasing number of diseases, the development of selective inhibitors of BMP4 is an attractive therapeutic option. The currently available BMP4 inhibitors are not suitable as therapeutics because of their low specificity and low effectiveness. Here, we compared newly generated anti-BMP4 llama-derived antibodies (VHHs) with 3 different types of commercially available BMP4 inhibitors, natural antagonists, small molecule BMPR inhibitors and conventional anti-BMP4 monoclonal antibodies. We found that the anti-BMP4 VHHs were as effective as the natural antagonist or small molecule inhibitors, but had higher specificity. We also showed that commercial anti-BMP4 antibodies were inferior in terms of both specificity and effectiveness. These findings might result from the fact that the VHHs C4C4 and C8C8 target a small region within the BMPR1 epitope of BMP4, whereas the commercial antibodies target other areas of the BMP4 molecule. Our results show that the newly developed anti-BMP4 VHHs are promising antibodies with better specificity and effectivity for inhibition of BMP4, making them an attractive tool for research and for therapeutic applications.

  10. Characterization and efficacy determination of commercially available Central American H5N2 avian influenza vaccines for poultry.

    Science.gov (United States)

    Eggert, Dawn; Thomas, Colleen; Spackman, Erica; Pritchard, Nikki; Rojo, Francisco; Bublot, Michel; Swayne, David E

    2010-06-23

    A poultry vaccination program was implemented in Central America beginning in January 1995 to control both H5N2 low (LPAI) and high pathogenicity avian influenza. This study was conducted to identify seed strain composition and the efficacy of 10 commercially available H5 vaccines against challenge with H5N2 LPAI viruses isolated from Latin America in 2003. The original 1994 vaccine seed virus in commercial inactivated vaccines did not significantly reduce challenge virus shed titers. However, two seed strains of inactivated vaccines, genetically more closely related to the challenge virus, did significantly reduce titers of challenge virus shed from respiratory tract. In addition, a live recombinant fowlpox virus vaccine containing a more distantly related Eurasian lineage H5 gene insert significantly reduced respiratory shedding as compared to sham vaccinates. These results demonstrate the feasibility of identifying vaccine seed strains in commercial finished products for regulatory verification and the need for periodic challenge testing against current field strains in order to select efficacious vaccine seed strains. (c) 2010 Elsevier Ltd. All rights reserved.

  11. Comparative evaluation of antibacterial effect of three commercially available herbal products against Streptococcus mutans: An In vitro Study

    Directory of Open Access Journals (Sweden)

    Sharanya Sreekumar

    2018-01-01

    Full Text Available Background: In recent years, the researches concerning the use of herbal products have been vastly analyzed to decrease the disease burden caused by dental caries. It has been found that certain phytochemicals present in the plants have certain inhibitory effect toward Streptococcus mutans which is currently the main causative organism for dental caries initiation. Hence, in the present study, certain commercial herbal products have been tested for their antibacterial effect. Aim: This study aims to compare the antibacterial action of three commercially available herbal products against S. mutans. Material and Methods: An in vitro study was conducted with commercially available herbal products. They were Aloe Barbadensis Miller (Aloe vera, Ocimum tenuiflorum (Thulasi, and Stevia rebaudiana (Stevia. The antimicrobial effectiveness (zone of inhibition of herbal products was determined using agar well diffusion method. Pure strains of S. mutans MTCC 890 were procured from culture collection center, Imtech, Chandigarh. The culture was grown in Brain Heart Infusion Agar, and around 20 ml each was poured into sterile petri plates. Chlorhexidine (CHX was taken as positive control, and distilled water was taken as negative control. Statistical analysis was done using SPSS version 17 software. Results: All herbal products were found to be having variable antimicrobial activity against S. mutans. The mean zone of inhibition after 24 h incubation measured for Stevia, Thulasi, and A. vera was 22.33 mm, 11 mm, and 0 mm, respectively. The mean zone of inhibition of positive control CHX was found to be 13.6 mm. Conclusion: The antibacterial effect shown by Stevia was superior when compared with CHX and Thulasi. The Thulasi have more inhibitory effect than A. vera, and A. vera fails to show any zone of inhibition against S. mutans when compared with other herbal products. Thus, Stevia product can be strongly recommended as a caries preventing agent after

  12. THE TESTING OF COMMERCIALLY AVAILABLE ENGINEERING AND PLANT SCALE ANNULAR CENTRIFUGAL CONTACTORS FOR THE PROCESSING OF SPENT NUCLEAR FUEL

    International Nuclear Information System (INIS)

    Jack D. Law; David Meikrantz; Troy Garn; Nick Mann; Scott Herbst

    2006-01-01

    Annular centrifugal contactors are being evaluated for process scale solvent extraction operations in support of United State Advanced Fuel Cycle Initiative goals. These contactors have the potential for high stage efficiency if properly employed and optimized for the application. Commercially available centrifugal contactors are being tested at the Idaho National Laboratory to support this program. Hydraulic performance and mass transfer efficiency have been measured for portions of an advanced nuclear fuel cycle using 5-cm diameter annular centrifugal contactors. Advanced features, including low mix sleeves and clean-in-place rotors, have also been evaluated in 5-cm and 12.5-cm contactors

  13. Responses of commercially available neutron electronic personal dosemeters in neutron fields simulating workplaces at MOX fuel fabrication facilities

    International Nuclear Information System (INIS)

    Tsujimura, N.; Yoshida, T.; Takada, C.

    2011-01-01

    The authors investigated the performance of three commercially available electronic personal dosemeters (EPDs) in evaluating neutron dose equivalents and discussed their suitability to work environments in MOX fuel fabrication facilities. The EPDs selected for this study were NRY21 (Fuji Electric Systems), PDM-313 (Aloka) and DMC 2000 GN (MGP Instruments). All tests were conducted in moderated 252 Cf neutron fields with neutron spectral and dosimetric characteristics similar to those found in MOX fuel facilities. The test results revealed trends and the magnitude of response variations in relation to neutron spectral changes expected in work environments.

  14. Flavanols and methylxanthines in commercially available dark chocolate: a study of the correlation with nonfat cocoa solids.

    Science.gov (United States)

    Langer, Swen; Marshall, Lisa J; Day, Andrea J; Morgan, Michael R A

    2011-08-10

    Intake of flavanols, a subgroup of dietary polyphenols present in many fruits and vegetables, may be associated with health benefits, particularly with reducing the risk of coronary diseases. Cocoa and chocolate products are rich in flavanol monomers, oligomers, and polymers (procyanidins). This study used normal phase HPLC to detect, identify, and quantify epicatechin, catechin, total monomers, procyanidin oligomers and polymers in 14 commercially available chocolate bars. In addition, methylxanthines (theobromine and caffeine) were also quantified. Nonfat cocoa solids (NFCS) were determined both gravimetrically and by calculation from theobromine contents. The flavanol levels of 12 commonly consumed brands of dark chocolate have been quantified and correlated with % theobromine and % NFCS. Epicatechin comprised the largest fraction of total chocolate flavonoids, with the remainder being catechin and procyanidins. Calculated NFCS did not reflect epicatechin (R(2) = 0.41) or total flavanol contents (R(2) = 0.49). Epicatechin (R(2) = 0.96) was a reliable marker of total flavanols, catechin (R(2) = 0.67) to a lesser extent. All dark chocolate tested contained higher levels of total flavanols (93.5-651.1 mg of epicatechin equiv/100 g of product) than a milk or a white "chocolate" (40.6 and 0.0 mg of epicatechin equiv/100 g, respectively). The amount and integrity of procyanidins often suffer in the manufacturing of chocolate, chiefly due to oxidation and alkalinization. In this study, the labeled cocoa content of the chocolate did not always reflect analyzed levels of flavonoids. Increasingly, high % NFCS is being used commercially to reflect chocolate quality. If the flavanol content of chocolate is accepted to be a key determinant of health benefits, then continued monitoring of flavanol levels in commercially available chocolate products may be essential for consumer assurance.

  15. A comparison of decontamination effects of commercially available detergents in rats pre-exposed to topical sulphur mustard.

    Science.gov (United States)

    Misik, Jan; Jost, Petr; Pavlikova, Ruzena; Vodakova, Eva; Cabal, Jiri; Kuca, Kamil

    2013-06-01

    The genotoxic vesicant sulphur mustard [bis-2-(chloroethyl)sulphide] is a chemical warfare agent which is easily available due to its relatively simple synthesis. Thus, sulphur mustard is a potential agent for mass contamination. In this study, we focused on sulphur mustard toxicity and decontamination in a rat model using commercially available detergent mixtures for dermal decontamination. Male Wistar rats were percutaneously treated with sulphur mustard and subjected to wet decontamination 2 min postexposure. Commercially produced detergents Neodekont™, Argos™, Dermogel™ and FloraFree™ were tested for their decontamination efficacy against an exposed group and their protective ratios determined. The results showed that all tested detergent solutions produced an increase in the median lethal dose [LD(50) = 9.83 (5.87-13.63) mg·kg(-1)] in comparison to controls, which led to increased survival of experimental animals. In general, all tested detergents provided modest decontamination efficacy (PR = 2.0-5.7). The highest protective ratio (5.7) was consistently achieved with Argos™. Accordingly, Argos™ should be considered in further investigation of mass casualty decontamination.

  16. An in vitro study to evaluate the difference in shade between commercially available shade guides and glazed porcelain

    Directory of Open Access Journals (Sweden)

    P Manimaran

    2016-01-01

    Full Text Available Introduction: Smile is one of the most important interactive communication skills of a person. A smile is the key factor for an aesthetic appearance. Hence aesthetics is one of the motivating factor for the patients to seek dental care. Correction of unaesthetic appearance gives a positive effect to the self esteem of the patient. Aim: The aim of this study was to compare the difference in the shade between the commercially available shade guides namely Vita Classical And Ivoclar Chromascop and the fired porcelain samples fabricated using Vita Zahnfabrik VMK 95 and Ivoclar Classic Materials respectively. Objectives: The objective of this study was to obtain a matching brand of material that has a particular shade tab among the brands used. Conclusion: To conclude, Ivoclar material matched the chromascop shade guide better than the vita material matched the vita classic shade guide.

  17. Estimation of Fluoride Concentration of Various Citrus and Non-Citrus Fruits Commonly Consumed and Commercially Available in Mathura City

    Directory of Open Access Journals (Sweden)

    Navin Anand Ingle

    2013-01-01

    Full Text Available Background: Since fluoride is available from various sources, the total ingestion of fluoride by a person should be estimated taking into consideration the fluoride consumed from all the sources including fruits. There are very few epidemiological studies carried out associated with fluoride estimation in fruit samplesand especially in the Indian scenario Objective: To estimate and compare the fluoride concentration of different commercially available citrus and non-citrus fruits in Mathura city. Materials & Method: Fifteen different types of fruits commercially available and consumed by people ofMathura City were collected. Out of the 15 fruit samples 5 were citrus fruits and 10 were non-citrus fruits. The fluoride estimation of fruit samples was done at Central Laboratory,Lucknow. Juices of all 15 fruit samples were prepared, from each sample 10 ml of juice was measured and fluoride testing of each sample was carried out by using Orion 4 star -ion electrode analyzer. The collected data was analyzed using the statistical software program SPSS, version 17. Results: The fluoride concentration in citrus fruits ranged from 0.04ppm (Orange to 0.08 ppm (Tomato while in non-citrus fruits it ranged from 0.04ppm (chikoo to 0.18 ppm (Guava. No significant difference was observed between the mean fluoride concentration of citrus and non citrus fruits. Conclusions: Both citrus and non citrus fruits have fluorides. Guava was found to have the maximumamount of fluoridecontent (0.18 ppm among both the citrus and non citrus fruits.

  18. Comparison of allergenicity and immunogenicity of an intact allergen vaccine and commercially available allergoid products for birch pollen immunotherapy.

    Science.gov (United States)

    Lund, L; Henmar, H; Würtzen, P A; Lund, G; Hjortskov, N; Larsen, J N

    2007-04-01

    Specific immunotherapy with intact allergen vaccine is a well-documented treatment for allergic diseases. Different vaccine formulations are currently commercially available, the active ingredient either being intact allergens or chemically modified allergoids. The rationale behind allergoids is to decrease allergenicity while maintaining immunogenicity. However, data from the German health authorities based on reporting of adverse events over a 10-year period did not indicate increased safety of allergoids over intact allergens. The objective of this study was to investigate the effect of chemical modification on allergenicity and immunogenicity comparing four commercial allergoid products for birch pollen immunotherapy with an intact allergen vaccine. Solid-phase IgE inhibition and histamine release assays were selected as model systems for allergenicity, and a combination of human T cell proliferation and IgG titres following mouse immunizations were used to address the immunogenicity of the intact allergen vaccine and the four allergoids. In all assays, the products were normalized with respect to the manufacturer's recommended maintenance dose. IgE inhibition experiments showed a change in epitope composition comparing intact allergen vaccine with allergoid. One allergoid product induced enhanced histamine release compared to the intact allergens, while the other three allergoids showed reduced release. Standard T cell stimulation assays using lines from allergic patients showed a reduced response for all allergoids compared with the intact allergen vaccine regardless of the cell type used for antigen presentation. All allergoids showed reduced capacity to induce allergen-specific IgG responses in mice. While some allergoids were associated with reduced allergenicity, a clear reduction in immunogenicity was observed for all allergoid products compared with the intact allergen vaccine, and the commercial allergoids tested therefore do not fulfil the allergoid

  19. High-performance liquid chromatographic analysis of cyclosporin A in rat blood and liver using a commercially available internal standard.

    Science.gov (United States)

    Chimalakonda, Anjaneya P; Shah, Rakhi B; Mehvar, Reza

    2002-05-25

    All the available HPLC assays of cyclosporin A (CyA) use internal standards that are not commercially available. Our purpose was to develop an HPLC assay for measurements of CyA in rat blood and liver using a commercially available internal standard (I.S.). After the addition of tamoxifen (I.S.), blood (0.25 ml) or the liver homogenate (1 ml) samples were extracted into a mixture of ether:methanol (95:5). The residue after evaporation of the organic layer was dissolved in 200 microl of an injection solution and washed with 1 ml of hexane before analysis. The separation was achieved using an LC-1 column (70 degrees C) with a mobile phase of methanol-acetonitrile-0.01 M KH(2)PO(4) (50:25:25, v/v) and a flow-rate of 1 ml/min. Detection was at 205 nm. Cyclosporin A and I.S. eluted at 5 and 7 min, respectively, free from endogenous peaks. Linear relationships (r>0.98) were observed between the CyA:I.S. peak area ratios and the CyA concentrations within the range of 0.2-10 microg/ml for blood and 0.1-4 microg/ml for the liver homogenates. The intra- and inter-run C.V.s and errors for both the blood and liver samples were <15%. The extraction efficiency (n=5) was close to 100% for both CyA and I.S. in both blood and liver homogenates. The lower limit of quantitation of the assay was 0.2 or 0.1 microg/ml based on 250 microl of blood or 1 ml of liver homogenate, respectively. The assay was capable of measuring blood and liver concentrations of CyA in a rat injected intravenously with a single 5-mg/kg dose of the drug.

  20. Effects of Three Commercially Available Sports Drinks on Substrate Metabolism and Subsequent Endurance Performance in a Postprandial State.

    Science.gov (United States)

    Qin, Lu; Wang, Qi-Rong; Fang, Zi-Long; Wang, Ting; Yu, Ai-Qi; Zhou, Yu-Jie; Zheng, Yi; Yi, Mu-Qing

    2017-04-12

    Purpose: To examine the effects of commercially available sports beverages with various components on substrate metabolism and subsequent performance. Methods: Two studies were conducted in a double-blinded, counterbalanced manner. Study I was designed to determine the glycemic index, while study II determined the utilization of substrates and subsequent exercise performance. Ten healthy male participants (age 21.70 ± 2.41 years, height 176.60 ± 5.23 cm, weight 66.58 ± 5.38 kg, V̇O 2max 48.1 ± 8.4 mL/kg/min) participated in both study I and study II. Three types of commercially available sports beverage powders were used. The powders consisted primarily of oligosaccharides (low molecular weight carbohydrates, L-CHO), hydrolyzed starch (high molecular weight CHO, H-CHO), and whey protein powder with carbohydrate (CHO-PRO). They were dissolved in purified water with identical CHO concentration of 8% ( w / v ). In study I, each participant underwent two oral glucose tolerance tests (OGTT) and one glycemic response test for each sports drink. In study II, participants cycled for 60 min at 70% V̇O 2max , one hour after consuming a standardized breakfast. One of four prescribed beverages (L-CHO, H-CHO, CHO-PRO, and Placebo control, PLA) was served at 0, 15, 30, 45 min during the exercise. Six hours after the first exercise session, participants came back for a "time to exhaustion test" (TTE). Blood samples were drawn at 0, 30, and 60 min in the first exercise session, while arterial blood gas analysis was conducted at 0, 30, and 60 min in both sessions. Subjective feelings (rating of perceived exertion and abdominal discomfort) were also evaluated every 30 min during exercise. Results: Compared to the reference standardized glucose solution, the glycemic index of the L-CHO beverage was 117.70 ± 14.25, while H-CHO was 105.50 ± 12.82, and CHO-PRO was 67.23 ± 5.88. During the exercise test, the insulin level at 30 and 60 min was significantly lower than baseline

  1. Assessment of commercially available energy-efficient room air conditioners including models with low global warming potential (GWP) refrigerants

    Energy Technology Data Exchange (ETDEWEB)

    Shah, N. K. [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Park, W. Y. [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Gerke, B. [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States)

    2017-08-30

    Improving the energy efficiency of room air conditioners (RACs) while transitioning to low global-warming-potential (GWP) refrigerants will be a critical step toward reducing the energy, peak load, and emissions impacts of RACs while keeping costs low. Previous research quantified the benefits of leapfrogging to high efficiency in tandem with the transition to low-GWP refrigerants for RACs (Shah et al., 2015) and identified opportunities for initial action to coordinate energy efficiency with refrigerant transition in economies constituting about 65% of the global RAC market (Shah et al., 2017). This report describes further research performed to identify the best-performing (i.e., most efficient and low-GWP-refrigerant using) RACs on the market, to support an understanding of the best available technology (BAT). Understanding BAT can help support market-transformation programs for high-efficiency and low-GWP equipment such as minimum energy performance standards (MEPS), labeling, procurement, and incentive programs. We studied RACs available in six economies—China, Europe, India, Japan, South Korea, and the United States—that together account for about 70% of global RAC demand, as well as other emerging economies. The following are our key findings: • Highly efficient RACs using low-GWP refrigerants, e.g., HFC-32 (R-32) and HC-290 (R-290), are commercially available today at prices comparable to similar RACs using high-GWP HCFC-22 (R-22) or HFC-410A (R-410A). • High efficiency is typically a feature of high-end products. However, highly efficient, cost-competitive (less than 1,000 or 1,500 U.S. dollars in retail price, depending on size) RACs are available. • Where R-22 is being phased out, high GWP R-410A still dominates RAC sales in most mature markets except Japan, where R-32 dominates. • In all of the economies studied except Japan, only a few models are energy efficient and use low-GWP refrigerants. For example, in Europe, India, and Indonesia

  2. Quantifying the foodscape: A systematic review and meta-analysis of the validity of commercially available business data

    Science.gov (United States)

    Lebel, Alexandre; Daepp, Madeleine I. G.; Block, Jason P.; Walker, Renée; Lalonde, Benoît; Kestens, Yan; Subramanian, S. V.

    2017-01-01

    This paper reviews studies of the validity of commercially available business (CAB) data on food establishments (“the foodscape”), offering a meta-analysis of characteristics associated with CAB quality and a case study evaluating the performance of commonly-used validity indicators describing the foodscape. Existing validation studies report a broad range in CAB data quality, although most studies conclude that CAB quality is “moderate” to “substantial”. We conclude that current studies may underestimate the quality of CAB data. We recommend that future validation studies use density-adjusted and exposure measures to offer a more meaningful characterization of the relationship of data error with spatial exposure. PMID:28358819

  3. Generic requirements specification for qualifying a commercially available PLC for safety-related applications in nuclear power plants. Final report

    International Nuclear Information System (INIS)

    Ostenso, A.; May, R.

    1996-12-01

    This is a specification for qualifying a commercially available PLC for application to safety systems in nuclear power plants. The specifications are suitable for evaluating a particular PLC product line as a platform for safety-related applications, establishing a suitable qualification test program, and confirming that the manufacturer has a quality assurance program that is adequate for safety-related applications or is sufficiently complete that, with a reasonable set of compensatory actions, it can be brought into conformance. The specification includes requirements for: (1) quality assurance measures applied to the qualification activities, (2) documentation to support the qualification, and (3) documentation to provide the information needed for applying the qualified PLC platform to a specific application. The specifications are designed to encompass a broad range of safety applications; however, qualifying a particular platform for a different range of applications can be accomplished by appropriate adjustments to the requirements

  4. An in vitro study to evaluate the difference in shade between commercially available shade guides and glazed porcelain.

    Science.gov (United States)

    Manimaran, P; Sadan, D Sai

    2016-10-01

    Smile is one of the most important interactive communication skills of a person. A smile is the key factor for an aesthetic appearance. Hence aesthetics is one of the motivating factor for the patients to seek dental care. Correction of unaesthetic appearance gives a positive effect to the self esteem of the patient. The aim of this study was to compare the difference in the shade between the commercially available shade guides namely Vita Classical And Ivoclar Chromascop and the fired porcelain samples fabricated using Vita Zahnfabrik VMK 95 and Ivoclar Classic Materials respectively. The objective of this study was to obtain a matching brand of material that has a particular shade tab among the brands used. To conclude, Ivoclar material matched the chromascop shade guide better than the vita material matched the vita classic shade guide.

  5. Oral bioaccessibility of toxic and essential elements in raw and cooked commercial seafood species available in European markets

    KAUST Repository

    Alves, Ricardo N.; Maulvault, Ana L.; Barbosa, Vera L.; Fernandez-Tejedor, Margarita; Tediosi, Alice; Kotterman, Michiel; van den Heuvel, Fredericus H.M.; Robbens, Johan; Fernandes, José O.; Romme Rasmussen, Rie; Sloth, Jens J.; Marques, Antó nio

    2017-01-01

    The oral bioaccessibility of several essential and toxic elements was investigated in raw and cooked commercially available seafood species from European markets. Bioaccessibility varied between seafood species and elements. Methylmercury bioaccessibility varied between 10 (octopus) and 60% (monkfish). Arsenic (>64%) was the toxic element showing the highest bioaccessibility. Concerning essential elements bioaccessibility in raw seafood, selenium (73%) and iodine (71%) revealed the highest percentages. The bioaccessibility of elements in steamed products increased or decreased according to species. For example, methylmercury bioaccessibility decreased significantly after steaming in all species, while zinc bioaccessibility increased in fish (tuna and plaice) but decreased in molluscs (mussel and octopus).Together with human exposure assessment and risk characterization, this study could contribute to the establishment of new maximum permissible concentrations for toxic elements in seafood by the European food safety authorities, as well as recommended intakes for essential elements.

  6. Oral bioaccessibility of toxic and essential elements in raw and cooked commercial seafood species available in European markets

    KAUST Repository

    Alves, Ricardo N.

    2017-11-17

    The oral bioaccessibility of several essential and toxic elements was investigated in raw and cooked commercially available seafood species from European markets. Bioaccessibility varied between seafood species and elements. Methylmercury bioaccessibility varied between 10 (octopus) and 60% (monkfish). Arsenic (>64%) was the toxic element showing the highest bioaccessibility. Concerning essential elements bioaccessibility in raw seafood, selenium (73%) and iodine (71%) revealed the highest percentages. The bioaccessibility of elements in steamed products increased or decreased according to species. For example, methylmercury bioaccessibility decreased significantly after steaming in all species, while zinc bioaccessibility increased in fish (tuna and plaice) but decreased in molluscs (mussel and octopus).Together with human exposure assessment and risk characterization, this study could contribute to the establishment of new maximum permissible concentrations for toxic elements in seafood by the European food safety authorities, as well as recommended intakes for essential elements.

  7. A comparative evaluation of the marginal accuracy of crowns fabricated from four commercially available provisional materials: An in vitro study

    Science.gov (United States)

    Amin, Bhavya Mohandas; Aras, Meena Ajay; Chitre, Vidya

    2015-01-01

    Purpose: The purpose of this in vitro study was to evaluate and compare the primary marginal accuracy of four commercially available provisional materials (Protemp 4, Luxatemp Star, Visalys Temp and DPI tooth moulding powder and liquid) at 2 time intervals (10 and 30 min). Materials and Methods: A customized stainless steel master model containing two interchangeable dies was used for fabrication of provisional crowns. Forty crowns (n = 10) were fabricated, and each crown was evaluated under a stereomicroscope. Vertical marginal discrepancies were noted and compared at 10 min since the start of mixing and then at 30 min. Observations and Results: Protemp 4 showed the least vertical marginal discrepancy (71.59 μ), followed by Luxatemp Star (91.93 μ) at 10 min. DPI showed a marginal discrepancy of 95.94 μ while Visalys Temp crowns had vertical marginal discrepancy of 106.81 μ. There was a significant difference in the marginal discrepancy values of Protemp 4 and Visalys Temp. At 30 min, there was a significant difference between the marginal discrepancy of Protemp 4 crowns (83.11 μ) and Visalys Temp crowns (128.97 μ) and between Protemp 4 and DPI (118.88 μ). No significant differences were observed between Protemp 4 and Luxatemp Star. Conclusion: The vertical marginal discrepancy of temporary crowns fabricated from the four commercially available provisional materials ranged from 71 to 106 μ immediately after fabrication (at 10 min from the start of mix) to 83–128 μ (30 min from the start of mix). The time elapsed after mixing had a significant influence on the marginal accuracy of the crowns. PMID:26097348

  8. In-depth evaluation of commercially available human vascular smooth muscle cells phenotype: Implications for vascular tissue engineering

    International Nuclear Information System (INIS)

    Timraz, Sara B.H.; Farhat, Ilyas A.H.; Alhussein, Ghada; Christoforou, Nicolas; Teo, Jeremy C.M.

    2016-01-01

    In vitro research on vascular tissue engineering has extensively used isolated primary human or animal smooth muscle cells (SMC). Research programs that lack such facilities tend towards commercially available primary cells sources. Here, we aim to evaluate the capacity of commercially available human SMC to maintain their contractile phenotype, and determine if dedifferentiation towards the synthetic phenotype occurs in response to conventional cell culture and passaging without any external biochemical or mechanical stimuli. Lower passage SMC adopted a contractile phenotype marked by a relatively slower proliferation rate, higher expression of proteins of the contractile apparatus and smoothelin, elongated morphology, and reduced deposition of collagen types I and III. As the passage number increased, migratory capacity was enhanced, average cell speed, total distance and net distance travelled increased up to passage 8. Through the various assays, corroborative evidence pinpoints SMC at passage 7 as the transition point between the contractile and synthetic phenotypes, while passage 8 distinctly and consistently exhibited characteristics of synthetic phenotype. This knowledge is particularly useful in selecting SMC of appropriate passage number for the target vascular tissue engineering application, for example, a homeostatic vascular graft for blood vessel replacement versus recreating atherosclerotic blood vessel model in vitro. - Highlights: • Ability of human smooth muscle cells to alter phenotype in culture is evaluated. • Examined the effect of passaging human smooth muscle cells on phenotype. • Phenotype is assessed based on morphology, proliferation, markers, and migration. • Multi-resolution assessment methodology, single-cell and cell-population. • Lower and higher passages than P7 adopted a contractile and synthetic phenotype respectively.

  9. Measurements of bone mineral density of the proximal femur by two commercially available dual energy X-ray absorptiometric systems

    International Nuclear Information System (INIS)

    Svendsen, O.L.; Marslew, U.; Hassager, C.; Christiansen, C.

    1992-01-01

    Two dual energy X-ray absorptiometric (DXA) instruments have recently become commercially available for local bone densitometry: the QDR-1000 (Hologic Inc.) and the DPX (Lunar Radiation Corp.). We report the precision, influence of femoral, rotation, correlation and agreement of bone mineral measurements of the proximal fermur by these two instruments. In vitro (femur phantom) short-term precision was 1.1%-3.5%, and the long-term precision was 1.2%-3.8%. In vivo (groups of 10 premenopausal and 10 postmenopausal women) short-term precision of duplicate measurements was 1.6%-4.7%, and long-term precision was 1.9%-5.5%. Overall, the precision for Ward's triangle was over 3% and that for the femoral neck and trochanter, 2%-3%. Rotation of the femur phantom produced a statistically significant change in the bone mineral density (BMD) of the femoral neck. Within a clinically relevant range of femoral rotation (20deg inward rotation ±5deg) the coefficient of variation (CV%) increased by a mean factor of 1.1-1.4. Although the correlation (r<0.9) between BMD measurements of the proximal femur by the DPX and QDR-1000 in 30 postmenopausal women was high, there was lack of agreement between the two instruments. We found no statistically significant differences between the right and left femur in 30 postmenopausal women. A bilateral femur scan took a mean total time of about 22 min. We conclude that with the introduction of DXA instruments, the precision of bone mineral measurments of the proximal femur has improved. However, for comparability between commercially available DXA instruments, it might be advantageous if units were standardized. (orig.)

  10. Using a magnetite/thermoplastic composite in 3D printing of direct replacements for commercially available flow sensors

    International Nuclear Information System (INIS)

    Leigh, S J; Purssell, C P; Billson, D R; Hutchins, D A

    2014-01-01

    Flow sensing is an essential technique required for a wide range of application environments ranging from liquid dispensing to utility monitoring. A number of different methodologies and deployment strategies have been devised to cover the diverse range of potential application areas. The ability to easily create new bespoke sensors for new applications is therefore of natural interest. Fused deposition modelling is a 3D printing technology based upon the fabrication of 3D structures in a layer-by-layer fashion using extruded strands of molten thermoplastic. The technology was developed in the late 1980s but has only recently come to more wide-scale attention outside of specialist applications and rapid prototyping due to the advent of low-cost 3D printing platforms such as the RepRap. Due to the relatively low-cost of the printers and feedstock materials, these printers are ideal candidates for wide-scale installation as localized manufacturing platforms to quickly produce replacement parts when components fail. One of the current limitations with the technology is the availability of functional printing materials to facilitate production of complex functional 3D objects and devices beyond mere concept prototypes. This paper presents the formulation of a simple magnetite nanoparticle-loaded thermoplastic composite and its incorporation into a 3D printed flow-sensor in order to mimic the function of a commercially available flow-sensing device. Using the multi-material printing capability of the 3D printer allows a much smaller amount of functional material to be used in comparison to the commercial flow sensor by only placing the material where it is specifically required. Analysis of the printed sensor also revealed a much more linear response to increasing flow rate of water showing that 3D printed devices have the potential to at least perform as well as a conventionally produced sensor. (paper)

  11. Process modeling of a reversible solid oxide cell (r-SOC) energy storage system utilizing commercially available SOC reactor

    International Nuclear Information System (INIS)

    Mottaghizadeh, Pegah; Santhanam, Srikanth; Heddrich, Marc P.; Friedrich, K. Andreas; Rinaldi, Fabio

    2017-01-01

    Highlights: • An electric energy storage system was developed based on a commercially available SOC reactor. • Heat generated in SOFC mode of r-SOC is utilized in SOEC operation of r-SOC using latent heat storage. • A round trip efficiency of 54.3% was reached for the reference system at atmospheric pressure. • An improved process system design achieved a round-trip efficiency of 60.4% at 25 bar. - Abstract: The increase of intermittent renewable energy contribution in power grids has urged us to seek means for temporal decoupling of electricity production and consumption. A reversible solid oxide cell (r-SOC) enables storage of surplus electricity through electrochemical reactions when it is in electrolysis mode. The reserved energy in form of chemical compounds is then converted to electricity when the cell operates as a fuel cell. A process system model was implemented using Aspen Plus® V8.8 based on a commercially available r-SOC reactor experimentally characterized at DLR. In this study a complete self-sustaining system configuration is designed by optimal thermal integration and balance of plant. Under reference conditions a round trip efficiency of 54.3% was achieved. Generated heat in fuel cell mode is exploited by latent heat storage tanks to enable endothermic operation of reactor in its electrolysis mode. In total, out of 100 units of thermal energy stored in heat storage tanks during fuel cell mode, 90% was utilized to offset heat demand of system in its electrolysis mode. Parametric analysis revealed the significance of heat storage tanks in thermal management even when reactor entered its exothermic mode of electrolysis. An improved process system design demonstrates a system round-trip efficiency of 60.4% at 25 bar.

  12. In-depth evaluation of commercially available human vascular smooth muscle cells phenotype: Implications for vascular tissue engineering

    Energy Technology Data Exchange (ETDEWEB)

    Timraz, Sara B.H., E-mail: sara.timraz@kustar.ac.ae [Department of Biomedical Engineering, Khalifa University, PO Box 127788, Abu Dhabi (United Arab Emirates); Farhat, Ilyas A.H., E-mail: ilyas.farhat@outlook.com [Department of Applied Mathematics and Sciences, Khalifa University, PO Box 127788, Abu Dhabi (United Arab Emirates); Alhussein, Ghada, E-mail: ghada.alhussein@kustar.ac.ae [Department of Biomedical Engineering, Khalifa University, PO Box 127788, Abu Dhabi (United Arab Emirates); Christoforou, Nicolas, E-mail: nicolas.christoforou@kustar.ac.ae [Department of Biomedical Engineering, Khalifa University, PO Box 127788, Abu Dhabi (United Arab Emirates); Department of Biomedical Engineering, Duke University, Durham, NC 27708 (United States); Teo, Jeremy C.M., E-mail: jeremy.teo@kustar.ac.ae [Department of Biomedical Engineering, Khalifa University, PO Box 127788, Abu Dhabi (United Arab Emirates)

    2016-05-01

    In vitro research on vascular tissue engineering has extensively used isolated primary human or animal smooth muscle cells (SMC). Research programs that lack such facilities tend towards commercially available primary cells sources. Here, we aim to evaluate the capacity of commercially available human SMC to maintain their contractile phenotype, and determine if dedifferentiation towards the synthetic phenotype occurs in response to conventional cell culture and passaging without any external biochemical or mechanical stimuli. Lower passage SMC adopted a contractile phenotype marked by a relatively slower proliferation rate, higher expression of proteins of the contractile apparatus and smoothelin, elongated morphology, and reduced deposition of collagen types I and III. As the passage number increased, migratory capacity was enhanced, average cell speed, total distance and net distance travelled increased up to passage 8. Through the various assays, corroborative evidence pinpoints SMC at passage 7 as the transition point between the contractile and synthetic phenotypes, while passage 8 distinctly and consistently exhibited characteristics of synthetic phenotype. This knowledge is particularly useful in selecting SMC of appropriate passage number for the target vascular tissue engineering application, for example, a homeostatic vascular graft for blood vessel replacement versus recreating atherosclerotic blood vessel model in vitro. - Highlights: • Ability of human smooth muscle cells to alter phenotype in culture is evaluated. • Examined the effect of passaging human smooth muscle cells on phenotype. • Phenotype is assessed based on morphology, proliferation, markers, and migration. • Multi-resolution assessment methodology, single-cell and cell-population. • Lower and higher passages than P7 adopted a contractile and synthetic phenotype respectively.

  13. Examination of commercially available copper oxide wire particles in combination with albendazole for control of gastrointestinal nematodes in lambs.

    Science.gov (United States)

    Burke, J M; Miller, J E; Terrill, T H; Smyth, E; Acharya, M

    2016-01-15

    Control of gastrointestinal nematodes (GIN) remains a critical issue due to the prevalence of anthelmintic resistance. The objective of the experiment was to determine the efficacy of copper oxide wire particles (COWP) from three commercial sources and a combination of COWP and albendazole to control GIN and/or Haemonchus contortus in lambs. Naturally infected Katahdin lambs in early June 2014 and 2015 were randomly assigned to receive no COWP (CON; n=9 and 12) or 2g COWP in a gel capsule as Copasure(®) (COP; n=4 and 17; Animax Ltd.), copper oxide-wire form (AUS; n=7 in 2014 only; Pharmplex), Ultracruz™ (ULT; n=8 and 15; Santa Cruz Animal Health™), no COWP and albendazole (CON+alb; n=10 in 2015 only; 15mg/kg BW; Valbazen(®); Zoetis Animal Health), or COWP+alb (n=7 and 11; in 2014, lambs were administered alb on day 3). Lambs grazed grass pastures as a group and were supplemented with 227g/lamb daily of a commercial grain mix (15% crude protein) and the same amount of alfalfa pellets. Feces were collected on days 0 (day of COWP treatment), 7, and 14 for determination of fecal egg counts (FEC). Pooled (2014) or pooled treatment group feces were cultured on days 0, 7, and 14 (2015 only) to determine GIN genera. Data were analyzed using repeated measures in a mixed model, and FEC were log transformed. The predominant GIN on day 0 was H. contortus (87%) in 2014, and there was a mixed population in 2015. The mean FEC was reduced by day 7 in AUS and ULT lambs (treatment×day, P=0.001), and all of the COWP products were similar. By day 14, the AUS FEC were lower than the CON and COP groups. When examining the combination of COWP and synthetic anthelmintic, the FEC of COWP+alb were reduced to nearly 0eggs/g (back-transformed) and lower than the other groups (treatment×day, P=0.001). The percentage of H. contortus in cultured feces was reduced to a greater extent in the COWP than CON or CON+alb groups of lambs. In a mixed GIN population, the COWP products appeared to

  14. Comparison of a commercially available oral nutritional supplement and intravenous fluid therapy for dehydration in dairy calves.

    Science.gov (United States)

    Taylor, Jared D; Rodenburg, Merel; Snider, Timothy A

    2017-06-01

    Calf scours is a primary cause of morbidity and mortality in the dairy industry. Effective treatments are needed to minimize death, maximize welfare, and maintain growth and productivity. The objective of this trial was to compare the efficacy of a commercially available nutritional supplement (Diaque, Boehringer-Ingelheim Vetmedica Inc., St. Joseph, MO) and i.v. lactated Ringer's solution (LRS) in rehydrating, preventing acidemia, and correcting electrolyte imbalances in an experimental model for calf scours. Twenty-four colostrum-fed suckling dairy calves were used in a modified crossover design. An osmotic diarrhea was induced by orally feeding commercial milk replacer modified with high level of sucrose to create a hypertonic milk solution, and administering oral hydrochlorothiazide and spironolactone for 48 h. The intention was to create a challenge sufficient to result in moderately dehydrated, standing calves without producing severe depression or loss of suckle. The efficacy of i.v. fluid therapy and a commercial nutritional supplement were subsequently compared for reversing the effects of the diarrheal disease. Treatment A consisted of administering the nutritional supplement according to label directions (100 g in 1.9 L of warm water, 3 times a day), and treatment B consisted of i.v. LRS (2 L, once a day). Clinical signs and laboratory results were obtained once daily by a blinded observer. The induction method was effective in creating the desired effect, as demonstrated by weight loss and subjective health and hydration scores. Both treatment groups experienced increases in body weight, base excess, and bicarbonate, and decreases in total protein and packed cell volume following treatment. Both i.v. LRS and Diaque are effective methods to correct hypovolemia and control derangements in acid-base status in calves with diarrhea and dehydration. The Authors. Published by the Federation of Animal Science Societies and Elsevier Inc. on behalf of the

  15. Rapid Salmonella detection in experimentally inoculated equine faecal and veterinary hospital environmental samples using commercially available lateral flow immunoassays.

    Science.gov (United States)

    Burgess, B A; Noyes, N R; Bolte, D S; Hyatt, D R; van Metre, D C; Morley, P S

    2015-01-01

    Salmonella enterica is the most commonly reported cause of outbreaks of nosocomial infections in large animal veterinary teaching hospitals and the closure of equine hospitals. Rapid detection may facilitate effective control practices in equine populations. Shipping and laboratory testing typically require ≥48 h to obtain results. Lateral flow immunoassays developed for use in food-safety microbiology provide an alternative that has not been evaluated for use with faeces or environmental samples. We aimed to identify enrichment methods that would allow commercially available rapid Salmonella detection systems (lateral flow immunoassays) to be used in clinical practice with equine faecal and environmental samples, providing test results in 18-24 h. In vitro experiment. Equine faecal and environmental samples were inoculated with known quantities of S. enterica serotype Typhimurium and cultured using 2 different enrichment techniques for faeces and 4 enrichment techniques for environmental samples. Samples were tested blindly using 2 different lateral flow immunoassays and plated on agar media for confirmatory testing. In general, commercial lateral flow immunoassays resulted in fewer false-negative test results with enrichment of 1 g faecal samples in tetrathionate for 18 h, while all environmental sample enrichment techniques resulted in similar detection rates. The limit of detection from spiked samples, ∼4 colony-forming units/g, was similar for all methods evaluated. The lateral flow immunoassays evaluated could reliably detect S. enterica within 18 h, indicating that they may be useful for rapid point-of-care testing in equine practice applications. Additional evaluation is needed using samples from naturally infected cases and the environment to gain an accurate estimate of test sensitivity and specificity and to substantiate further the true value of these tests in clinical practice. © 2014 EVJ Ltd.

  16. Evaluation of two commercially available ELISA kits for the determination of melatonin concentrations in amniotic fluid throughout pregnancy.

    Science.gov (United States)

    Bagci, Soyhan; Altuntas, Özlem; Katzer, David; Berg, Christoph; Willruth, Arne; Reutter, Heiko; Bartmann, Peter; Müller, Andreas; Zur, Berndt

    2017-01-01

    Background The aim of the present study is to evaluate the utility of extraction versus non-extraction-based commercial melatonin ELISA kits for determining the melatonin concentration in amniotic fluid obtained in early and late pregnancy. Methods Pregnancy duration less than 28 weeks was defined as early and from 28 weeks until delivery as late gestation. Nine samples were obtained in early and 18 in late pregnancy. Two commercially available melatonin ELISA kits (melatonin ELISA RE54021, including methanol-based extraction and direct saliva melatonin ELISA RE 54041, not including an extraction step, both from IBL-International, Germany) were used to determine melatonin concentrations in amniotic fluid. Results The mean melatonin concentration in ELISAs assayed by the non-extraction was significantly lower than those assayed after extraction. Subgroup analysis showed that there was no significant difference between melatonin concentration measured by non-extraction versus extraction ELISA in early pregnancy (11.2 ± 7.4 vs. 12.2 ± 7.7, respectively, P = 0.463) but that the mean melatonin concentration in late pregnancy was significantly lower when assayed by non-extraction ELISA than when assayed by extraction ELISA (14.8 ± 9.3 vs. 145.1 ± 179.3, respectively; P pregnancy was rather poor (r 2  = 0.271, P = 0.022), as opposed to the good correlation found in early pregnancy (r 2  = 0.929, P melatonin assay without an extraction step, such as direct saliva ELISA, does not seem to be a valid method to determine the melatonin concentration of amniotic fluid, especially in late gestation.

  17. A Commercially Available Portion-Controlled Diet Program Is More Effective for Weight Loss than a Self-Directed Diet: Results from a Randomized Clinical Trial

    Directory of Open Access Journals (Sweden)

    Chad M. Cook

    2017-11-01

    Full Text Available ObjectiveTo examine changes in weight and related outcomes in response to a commercial weight loss program compared to a self-directed diet in adults with overweight or obesity.DesignParticipants were randomly assigned [stratified by body mass index (BMI and age] to a commercial weight loss program (n = 38 or to a self-directed Dietary Approaches to Stop Hypertension (DASH diet (n = 40 for a 16-week period. Daily energy intake goals were 1,500 kcal/d for men and 1,200 kcal/d for women, except for the first week of the commercial program (1,000 kcal/d. This study was registered at http://ClinicalTrials.gov (NCT03017443.ParticipantsPrimarily Caucasian (71% women (n = 61 and men (n = 17 from the greater metropolitan area of the city of Chicago, IL, USA. with a mean baseline BMI of 34.4 kg/m2, body weight of 95.7 kg, and age of 50.4 years.ResultsData = mean (95% CI. At week 16, the commercial program group lost significantly more body weight [−5.9 (−7.5, −4.3 kg vs. −1.8 (−2.9, −0.8 kg; or −6.4 vs. −1.8% of initial body weight, respectively], fat mass [−4.4 (−5.7, −3.1 kg vs. −1.2 (−2.1, −0.4 kg] and total body circumference (chest + waist + hip + upper arm + thigh [−16.9 (−21.5, −12.3 cm vs. −5.8 (−9.0, −2.6 cm] (p < 0.01 for all. Additionally, more participants in the commercial program group lost a clinically meaningful amount of weight, defined as ≥5% of initial body weight, at week 16 (58% vs. 13%, p < 0.001.ConclusionThe commercial program resulted in greater weight loss and improvements in body composition/anthropometric parameters compared to a self-directed DASH diet over a 16-week period. Some important limitations were that no objective measurements of dietary intake or physical activity were collected to potentially ascertain the independent or combined effects of these components on weight loss (or lack thereof. Additionally, future

  18. Effects of Three Commercially Available Sports Drinks on Substrate Metabolism and Subsequent Endurance Performance in a Postprandial State

    Directory of Open Access Journals (Sweden)

    Lu Qin

    2017-04-01

    Full Text Available Purpose: To examine the effects of commercially available sports beverages with various components on substrate metabolism and subsequent performance. Methods: Two studies were conducted in a double-blinded, counterbalanced manner. Study I was designed to determine the glycemic index, while study II determined the utilization of substrates and subsequent exercise performance. Ten healthy male participants (age 21.70 ± 2.41 years, height 176.60 ± 5.23 cm, weight 66.58 ± 5.38 kg, V̇O2max 48.1 ± 8.4 mL/kg/min participated in both study I and study II. Three types of commercially available sports beverage powders were used. The powders consisted primarily of oligosaccharides (low molecular weight carbohydrates, L-CHO, hydrolyzed starch (high molecular weight CHO, H-CHO, and whey protein powder with carbohydrate (CHO-PRO. They were dissolved in purified water with identical CHO concentration of 8% (w/v. In study I, each participant underwent two oral glucose tolerance tests (OGTT and one glycemic response test for each sports drink. In study II, participants cycled for 60 min at 70% V̇O2max, one hour after consuming a standardized breakfast. One of four prescribed beverages (L-CHO, H-CHO, CHO-PRO, and Placebo control, PLA was served at 0, 15, 30, 45 min during the exercise. Six hours after the first exercise session, participants came back for a “time to exhaustion test” (TTE. Blood samples were drawn at 0, 30, and 60 min in the first exercise session, while arterial blood gas analysis was conducted at 0, 30, and 60 min in both sessions. Subjective feelings (rating of perceived exertion and abdominal discomfort were also evaluated every 30 min during exercise. Results: Compared to the reference standardized glucose solution, the glycemic index of the L-CHO beverage was 117.70 ± 14.25, while H-CHO was 105.50 ± 12.82, and CHO-PRO was 67.23 ± 5.88. During the exercise test, the insulin level at 30 and 60 min was significantly lower than

  19. ESBL Detection: Comparison of a Commercially Available Chromogenic Test for Third Generation Cephalosporine Resistance and Automated Susceptibility Testing in Enterobactericeae.

    Directory of Open Access Journals (Sweden)

    Mohamed Ramadan El-Jade

    Full Text Available Rapid detection and reporting of third generation cephalosporine resistance (3GC-R and of extended spectrum betalactamases in Enterobacteriaceae (ESBL-E is a diagnostic and therapeutic priority to avoid inefficacy of the initial antibiotic regimen. In this study we evaluated a commercially available chromogenic screen for 3GC-R as a predictive and/or confirmatory test for ESBL and AmpC activity in clinical and veterinary Enterobacteriaceae isolates. The test was highly reliable in the prediction of cefotaxime and cefpodoxime resistance, but there was no correlation with ceftazidime and piperacillin/tazobactam minimal inhibitory concentrations. All human and porcine ESBL-E tested were detected with exception of one genetically positive but phenotypically negative isolate. By contrast, AmpC detection rates lay below 30%. Notably, exclusion of piperacillin/tazobactam resistant, 3GC susceptible K1+ Klebsiella isolates increased the sensitivity and specificity of the test for ESBL detection. Our data further imply that in regions with low prevalence of AmpC and K1 positive E. coli strains chromogenic testing for 3GC-R can substitute for more time consuming ESBL confirmative testing in E. coli isolates tested positive by Phoenix or VITEK2 ESBL screen. We, therefore, suggest a diagnostic algorithm that distinguishes 3GC-R screening from primary culture and species-dependent confirmatory ESBL testing by βLACTATM and discuss the implications of MIC distribution results on the choice of antibiotic regimen.

  20. Anti-oxidant activity and major chemical component analyses of twenty-six commercially available essential oils

    Directory of Open Access Journals (Sweden)

    Hsiao-Fen Wang

    2017-10-01

    Full Text Available This study analyzed 26 commercially available essential oils and their major chemical components to determine their antioxidant activity levels by measuring their total phenolic content (TPC, reducing power (RP, β-carotene bleaching (BCB activity, trolox equivalent antioxidant capacity (TEAC, and 1,1-diphenyl-2-picrylhydrazyl free radical scavenging (DFRS ability. The clove bud and thyme borneol essential oils had the highest RP, BCB activity levels, and TPC values among the 26 commercial essential oils. Furthermore, of the 26 essential oils, the clove bud and ylang ylang complete essential oils had the highest TEAC values, and the clove bud and jasmine absolute essential oils had the highest DFRS ability. At a concentration of 2.5 mg/mL, the clove bud and thyme borneol essential oils had RP and BCB activity levels of 94.56% ± 0.06% and 24.64% ± 0.03% and 94.58% ± 0.01% and 89.33% ± 0.09%, respectively. At a concentration of 1 mg/mL, the clove bud and thyme borneol essential oils showed TPC values of 220.00 ± 0.01 and 69.05 ± 0.01 mg/g relative to gallic acid equivalents, respectively, and the clove bud and ylang ylang complete essential oils had TEAC values of 809.00 ± 0.01 and 432.33 ± 0.01 μM, respectively. The clove bud and jasmine absolute essential oils showed DFRS abilities of 94.13% ± 0.01% and 78.62% ± 0.01%, respectively. Phenolic compounds of the clove bud, thyme borneol and jasmine absolute essential oils were eugenol (76.08%, thymol (14.36% and carvacrol (12.33%, and eugenol (0.87%, respectively. The phenolic compounds in essential oils were positively correlated with the RP, BCB activity, TPC, TEAC, and DFRS ability.

  1. Ultra-performance liquid chromatographic determination of L-ergothioneine in commercially available classes of cow milk.

    Science.gov (United States)

    Sotgia, Salvatore; Pisanu, Elisabetta; Cambedda, Debora; Pintus, Gianfranco; Carru, Ciriaco; Zinellu, Angelo

    2014-09-01

    A new efficient and sensitive precolumn hydrophilic interaction ultra-performance liquid chromatography (HILIC-UPLC) method was established for the quantitative determination of L-ergothioneine (ERT) in milk. After derivatization of ERT with 7-diethylamino-3-[4-(iodoacetamido)phenyl]-4-methylcoumarin, chromatographic separation was achieved in a fairly short time, less than 5 min, on a 100 × 2.1 mm Waters Cortecs UPLC HILIC 1.6-μm column, by using a mixture of 30 mmol/L ammonium acetate/acetonitrile (10:90, v/v) as a mobile phase flowing isocratically at 0.9 mL/min. Limit of detection and the limit of quantification were 0.03 and 0.10 μmol/L, respectively. The method exhibited linearity in a concentration range of 0.16 and 5.08 μmol/L. Mean recovery was 106.66%, whereas intra- and interassay precisions were determined to be within 6 RSD%. On average, ERT concentration in different commercially available classes of cow milk was found to be 0.442 ± 0.191 μmol/L, with the highest levels in the ultra-high temperature milks and low values in the unprocessed and HTST whole milks. In this light, our experiments suggest that ERT could be used as a marker for the heat treatment of milk. © 2014 Institute of Food Technologists®

  2. Comparison of surface modified zirconia implants with commercially available zirconium and titanium implants: a histological study in pigs.

    Science.gov (United States)

    Gredes, Tomasz; Kubasiewicz-Ross, Pawel; Gedrange, Tomasz; Dominiak, Marzena; Kunert-Keil, Christiane

    2014-08-01

    New biomaterials and their various surface modifications should undergo in vitro and in vivo evaluation before clinical trials. The objective of our in vivo study was to evaluate the biocompatibility of newly created zirconium implant surfaces after implantation in the lower jaw of pigs and compare the osseointegration of these dental implants with commercially available zirconium and titanium implants. After a healing period of 12 weeks, a histological analysis of the soft and hard tissues and a histomorphometric analysis of the bone-implant contact (BIC) were performed. The implant surfaces showed an intimate connection to the adjacent bone for all tested implants. The 3 newly created zirconium implant surfaces achieved a BIC of 45% on average in comparison with a BIC of 56% from the reference zirconium implants and 35% from titanium implants. Furthermore, the new zirconium implants had a better attachment to gingival and bone tissues in the range of implant necks as compared with the reference implants. The results suggest that the new implants comparably osseointegrate within the healing period, and they have a good in vivo biocompatibility.

  3. Validation of 2 commercially available enzyme-linked immunosorbent assays for adiponectin determination in canine serum samples.

    Science.gov (United States)

    Tvarijonaviciute, Asta; Martínez-Subiela, Silvia; Ceron, José J

    2010-10-01

    The aim of this study was to validate 2 commercially available enzyme-linked immunosorbent assays (ELISAs) for adiponectin in dogs, 1 canine-specific and 1 originally designed for measurements in humans. Intra-assay and interassay precision was evaluated by multiple measurements in canine serum samples, and assay accuracy was indirectly determined by linearity under dilution. Interference caused by hemolysis and lipemia was also studied. Both assays were subsequently used for measuring adiponectin concentrations in clinically healthy dogs and those with different grades of obesity. The intra-assay and inter-assay precision was less than 7.5% and 13.5% in serum samples with low and high adiponectin concentrations, respectively. Lipemia and hemolysis did not affect the results of any of the assays. Both assays were able to differentiate lean dogs from those that were overweight or obese on the basis of the measured adiponectin concentrations. From these results it can be concluded that canine adiponectin concentrations can be measured reliably by means of the 2 ELISAs evaluated in this study.

  4. Effect of simulated chairside grinding procedures using commercially available abrasive agents on the surface properties of zirconia.

    Science.gov (United States)

    Sandhu, Ramandeep; Kheur, Mohit; Kheur, Supriya

    2017-01-01

    The aim of the present study was to assess the change in physical properties (surface roughness, surface hardness and phase transformation) after surface grinding of zirconia by using three commercially available abrasives. Thirty sintered zirconia specimens were prepared and divided into three groups namely Group M (grinded using Mani Dia diamond bur standard grit), Group T (grinded using Tri Hawk diamond bur coarse grit) and Group P (grinded using Predator carbide bur). A customised assembly was used to follow a standardised protocol for surface grinding. The surface roughness, surface hardness and phase transformation was recorded before and after the grinding procedure. ANOVA and Bonferroni post hoc test were used to assess the values obtained after the testing the surface roughness and surface hardness. The results of the present study revealed the average values of change in surface roughness as Group M (0.44 μ m) and Group T (1.235 μ m) and Group P (-0.88 μ m). The average values of change in surface hardness were Group T (19.578 HV), Group M (46.722 HV) and Group P (36.429 HV). The change in surface hardness was not statistically significant. There was no phase transformation seen after the grinding procedure. Carbide burs along with copious water irrigation when used to grind zirconia intra-orally produces has a polishing effect, minimal change in hardness & no phase transformation. The present study advocates the use of carbides for chair-side grinding of zirconia.

  5. Identification of Pre-pasteurization or Pre-irradiation Treatment in Frozen Crushed Garlic Commercially Available in Korean Market

    International Nuclear Information System (INIS)

    Kim, H.Y.; Ahn, J.J.; Kim, G.R.; Jeong, J.H.; Park, K.H.; Kwon, J.H.

    2013-01-01

    Five different chopped frozen garlic products samp les, three from Chinese an d two from Korean origins being commercially available products in Korean market, were used to confirm their pre-pasteurization or pre-irradiation status by screening (direct epifluorescent filter techni que/aerobic plate counts, DEFT/APC; electronic nose, E-nose; photostimulated luminescence, PSL) and identification (the rmoluminescence, TL; electron spin resonance, ESR) techniques. Some parts of samples were gamma-irradiated at 1 kGy to be used as control samples in irradiation history identification. DEFT/APC and e-nose succ essfully showed distinct results between the domestic and imported samples. The PSL photon counts of all the unknown samples were less than 700 (negative), while most of 1 kGy-irradiated samples gave PSL photon counts more than 5,000 (positiv e). The domestic unknown samples produced the TL glow peaks after 300°C or more, whereas the imported samples showed TL peaks at the range of 240 ~ 250°C. A clear TL glow peak was obtained from all irradiated samples at 150 ~ 250°C. The unknown samples of Chinese origin gave radiation-specific cellulose ESR signal that was not shown by domestic samples. A multiple step of applying the physical analytical methods is recommended for the effec tive identification of irradiation status on chopped frozen garlic products. (author)

  6. Magnetic resonance imaging and relaxometry to study water transport mechanisms in a commercially available gastrointestinal therapeutic system (GITS) tablet.

    Science.gov (United States)

    Broadbent, Amber L; Fell, Rob J; Codd, Sarah L; Lightley, Kim A; Konagurthu, Sanjay; Koehler-King, Dory G; Seymour, Joseph D

    2010-09-15

    The hydration of 4 mg Cardura XL (Pfizer), a commercially available gastrointestinal therapeutic system (GITS) tablet, was investigated using magnetic resonance imaging (MRI). A short echo time (T(e)=2.81 ms) technique for MRI of the hydration of a GITS tablet was implemented. From the MR images, signal intensity profiles were generated and interpreted in the context of diffusive and osmotic transport mechanisms. A distinct transition from diffusive to osmotic transport was measured at a timescale relevant to the measured drug release time. Diffusion and osmotic rate coefficients for water in the drug and polymer sweller layers of the tablet were quantified. Spin-lattice T(1) and spin-spin T(2) relaxation times of the water signal from within the tablet were measured as a function of hydration time in order to incorporate the effects of relaxation into interpretation of signal intensity and provide unique information on the distribution of water in different physical and chemical environments within the tablet. Copyright 2010 Elsevier B.V. All rights reserved.

  7. Clinical chemistry measurements with commercially available test slides on a smartphone platform: Colorimetric determination of glucose and urea.

    Science.gov (United States)

    Wu, Yuanyuan; Boonloed, Anukul; Sleszynski, Neal; Koesdjojo, Myra; Armstrong, Chadd; Bracha, Shay; Remcho, Vincent T

    2015-08-25

    Rapidly increasing healthcare costs in economically advantaged countries are currently unsustainable, while in many developing nations, even 50-year-old technologies are too expensive to implement. New and unconventional technologies are being explored as solutions to this problem. In this study, we examined the use of a smartphone as the detection platform for 2 well-developed, relatively inexpensive, commercially available clinical chemistry assays as a model for rapid and inexpensive clinical diagnostic testing. An Apple iPhone 4 camera phone equipped with a color analysis application (ColorAssist) was combined with Vitros® glucose and urea colorimetric assays. Color images of assay slides at various concentrations of glucose or urea were collected with the iPhone 4 and quantitated in three different spectral ranges (red/green/blue or RGB) using the ColorAssist app. When the diffuse reflectance data was converted into absorbance, it was possible to quantitate glucose or blood urea nitrogen (BUN) over their clinically important concentration ranges (30-515mg/dl for glucose or 2-190mg/dl for BUN), with good linearity (R(2)=0.9994 or 0.9996, respectively [n=5]). Data collected using the iPhone 4 and canine serum samples were in agreement with results from the instrumental "gold standard" (Beckman Coulter AU480 Chemistry System) (R(2)=0.9966 and slope=1.0001 for glucose; R(2)=0.9958 and slope=0.9454 for BUN). Glucose determinations of serum samples made using this smartphone method were as accurate as or more accurate than a commercial colorimetric dry slide analyzer (Heska® Element DC Chemistry Analyzer, Loveland, CO) and 2 glucometers: ReliOn® Ultima (Abbott Diabetes Care Inc) and Presto® (AgaMatrix Inc.H). BUN determinations made using the smartphone approach were comparable in accuracy to the Heska instrument. This demonstration shows that smartphones have the potential to be used as simple, effective colorimetric detectors for quantitative diagnostic tests

  8. Anti-oxidant activity and major chemical component analyses of twenty-six commercially available essential oils.

    Science.gov (United States)

    Wang, Hsiao-Fen; Yih, Kuang-Hway; Yang, Chao-Hsun; Huang, Keh-Feng

    2017-10-01

    This study analyzed 26 commercially available essential oils and their major chemical components to determine their antioxidant activity levels by measuring their total phenolic content (TPC), reducing power (RP), β-carotene bleaching (BCB) activity, trolox equivalent antioxidant capacity (TEAC), and 1,1-diphenyl-2-picrylhydrazyl free radical scavenging (DFRS) ability. The clove bud and thyme borneol essential oils had the highest RP, BCB activity levels, and TPC values among the 26 commercial essential oils. Furthermore, of the 26 essential oils, the clove bud and ylang ylang complete essential oils had the highest TEAC values, and the clove bud and jasmine absolute essential oils had the highest DFRS ability. At a concentration of 2.5 mg/mL, the clove bud and thyme borneol essential oils had RP and BCB activity levels of 94.56% ± 0.06% and 24.64% ± 0.03% and 94.58% ± 0.01% and 89.33% ± 0.09%, respectively. At a concentration of 1 mg/mL, the clove bud and thyme borneol essential oils showed TPC values of 220.00 ± 0.01 and 69.05 ± 0.01 mg/g relative to gallic acid equivalents, respectively, and the clove bud and ylang ylang complete essential oils had TEAC values of 809.00 ± 0.01 and 432.33 ± 0.01 μM, respectively. The clove bud and jasmine absolute essential oils showed DFRS abilities of 94.13% ± 0.01% and 78.62% ± 0.01%, respectively. Phenolic compounds of the clove bud, thyme borneol and jasmine absolute essential oils were eugenol (76.08%), thymol (14.36%) and carvacrol (12.33%), and eugenol (0.87%), respectively. The phenolic compounds in essential oils were positively correlated with the RP, BCB activity, TPC, TEAC, and DFRS ability. Copyright © 2017. Published by Elsevier B.V.

  9. Validation of commercially available sphingosine kinase 2 antibodies for use in immunoblotting, immunoprecipitation and immunofluorescence [version 2; referees: 2 approved

    Directory of Open Access Journals (Sweden)

    Heidi A. Neubauer

    2017-03-01

    Full Text Available Sphingosine kinase 2 (SK2 is a ubiquitously expressed lipid kinase that has important, albeit complex and poorly understood, roles in regulating cell survival and cell death. In addition to being able to promote cell cycle arrest and apoptosis under certain conditions, it has recently been shown that SK2 can promote neoplastic transformation and tumorigenesis in vivo. Therefore, well validated and reliable tools are required to study and better understand the true functions of SK2. Here, we compare two commercially available SK2 antibodies: a rabbit polyclonal antibody from Proteintech that recognizes amino acids 266-618 of human SK2a, and a rabbit polyclonal antibody from ECM Biosciences that recognizes amino acids 36-52 of human SK2a. We examine the performance of these antibodies for use in immunoblotting, immunoprecipitation and immunofluorescence staining of endogenous SK2, using human HEK293 and HeLa cell lines, as well as mouse embryonic fibroblasts (MEFs. Furthermore, we assess the specificity of these antibodies to the target protein through the use of siRNA-mediated SK2 knockdown and SK2 knockout (Sphk2-/- MEFs. Our results demonstrate that the Proteintech anti-SK2 antibody reproducibly displayed superior sensitivity and selectivity towards SK2 in immunoblot analyses, while the ECM Biosciences anti-SK2 antibody was reproducibly superior for SK2 immunoprecipitation and detection by immunofluorescence staining. Notably, both antibodies produced non-specific bands and staining in the MEFs, which was not observed with the human cell lines. Therefore, we conclude that the Proteintech SK2 antibody is a valuable reagent for use in immunoblot analyses, and the ECM Biosciences SK2 antibody is a useful tool for SK2 immunoprecipitation and immunofluorescence staining, at least in the human cell lines employed in this study.

  10. The reduction efficacy of dentinal hypersensitivity by two commercially available desensitizing toothpastes: Vantej and Colgate Pro- Argin

    Directory of Open Access Journals (Sweden)

    Aditya Rao

    2014-01-01

    Full Text Available Background : Dentin hypersensitivity is a commonly experienced problem that is triggered by an external stimulus, such as hot and cold temperature changes, pressure from tooth brushing and osmotic changes caused due to sweet or sour food and beverages. Various treatment modalities are tried and tested, amongst them desensitizing pastes have been used extensively in the past decades. Objective: The objective of these 15 days, single center, randomized clinical pilot study was to evaluate the dentin hypersensitivity reducing efficacy of two commercially available desensitizing toothpastes: One with Pro-Argin technology and the other with Novamin. Materials and Methods: Eighty subjects of dentin hypersensitivity were sampled in the present pilot study. Subjects were randomly selected and the pastes were prescribed for both the groups. Subjects were advised to brush twice daily for 2 min with the desensitizing paste and also were advised for topical application of the desensitizing paste on sensitive teeth and were asked not to rinse until morning. The evaluation was done by Air blast technique using sensitivity visual analog scale consisting of mild, moderate, and severe parameters rated on a scale of 0-10. Efficacy was compared on baseline, after 1 min of application and after 15 days. Statistical Analysis: t-test was performed and P value ≤ 0.05 was considered as statistically significant. Results: There was no statistically significant difference between the two groups after 1 min of examination, but there was a statistically significant difference in reduction of dentin hypersensitivity after 15 days interval favoring Vantej group (P ≤ 0.02. Conclusion: Desensitizing paste containing 5% NovaMin crystals provided a statistically significant reduction at 15 days interval when compared with the one containing Pro-Arginine.

  11. Dosage response mortality of Japanese beetle, masked chafer, and June beetle (Coleoptera: Scarabaeidae) adults when exposed to experimental and commercially available granules containing Metarhizium brunneum

    Science.gov (United States)

    Adult beetles of three different white grub species, Japanese beetle, Popillia japonica, June beetle, Phyllophaga spp., and masked chafer, Cyclocephala spp. were exposed to experimental and commercially available granules containing Metarhizium brunneum (Petch) strain F52, to determine susceptibilit...

  12. Automatic quantification of defect size using normal templates: a comparative clinical study of three commercially available algorithms

    International Nuclear Information System (INIS)

    Sutter, J. de; Wiele, C. van de; Bondt, P. de; Dierckx, R.; D'Asseler, Y.; Backer, G. de; Rigo, P.

    2000-01-01

    Infarct size assessed by myocardial single-photon emission tomography (SPET) imaging is an important prognostic parameter after myocardial infarction (MI). We compared three commercially available automatic quantification algorithms that make use of normal templates for the evaluation of infarct extent and severity in a large population of patients with remote MI. We studied 100 consecutive patients (80 men, mean age 63±11 years, mean LVEF 47%±15%) with a remote MI who underwent resting technetium-99m tetrofosmin gated SPET study for infarct extent and severity quantification. The quantification algorithms used for comparison were a short-axis algorithm (Cedars-Emory quantitative analysis software, CEqual), a vertical long-axis algorithm (VLAX) and a three-dimensional fitting algorithm (Perfit). Semiquantitative visual infarct extent and severity assessment using a 20-segment model with a 5-point score and the relation of infarct extent and severity with rest LVEF determined by quantitative gated SPET (QGS) were used as standards to compare the different algorithms. Mean infarct extent was similar for visual analysis (30%±21%) and the VLAX algorithm (25%±17%), but CEqual (15%±11%) and Perfit (5%±6%) mean infarct extents were significantly lower compared with visual analysis and the VLAX algorithm. Moreover, infarct extent determined by Perfit was significantly lower than infarct extent determined by CEqual. Correlations between automatic and visual infarct extent and severity evaluations were moderate (r=0.47, P 2 , n=32) compared with anterior infarctions and non-obese patients for all three algorithms. In this large series of post-MI patients, results of infarct extent and severity determination by automatic quantification algorithms that make use of normal templates were not interchangeable and correlated only moderately with semiquantitative visual analysis and LVEF. (orig.)

  13. Accuracy evaluation of fusion of CT, MR, and SPECT images using commercially available software packages (SRS PLATO and IFS)

    International Nuclear Information System (INIS)

    Mongioj, Valeria; Brusa, Anna; Loi, Gianfranco; Pignoli, Emanuele; Gramaglia, Alberto; Scorsetti, Marta; Bombardieri, Emilio; Marchesini, Renato

    1999-01-01

    Purpose: A problem for clinicians is to mentally integrate information from multiple diagnostic sources, such as computed tomography (CT), magnetic resonance (MR), and single photon emission computed tomography (SPECT), whose images give anatomic and metabolic information. Methods and Materials: To combine this different imaging procedure information, and to overlay correspondent slices, we used commercially available software packages (SRS PLATO and IFS). The algorithms utilize a fiducial-based coordinate system (or frame) with 3 N-shaped markers, which allows coordinate transformation of a clinical examination data set (9 spots for each transaxial section) to a stereotactic coordinate system. The N-shaped markers were filled with fluids visible in each modality (gadolinium for MR, calcium chloride for CT, and 99m Tc for SPECT). The frame is relocatable, in the different acquisition modalities, by means of a head holder to which a face mask is fixed so as to immobilize the patient. Position errors due to the algorithms were obtained by evaluating the stereotactic coordinates of five sources detectable in each modality. Results: SPECT and MR position errors due to the algorithms were evaluated with respect to CT: Δx was ≤ 0.9 mm for MR and ≤ 1.4 mm for SPECT, Δy was ≤ 1 mm and ≤ 3 mm for MR and SPECT, respectively. Maximal differences in distance between estimated and actual fiducial centers (geometric mismatch) were in the order of the pixel size (0.8 mm for CT, 1.4 mm for MR, and 1.8 mm for SPECT). In an attempt to distinguish necrosis from residual disease, the image fusion protocol was studied in 35 primary or metastatic brain tumor patients. Conclusions: The image fusion technique has a good degree of accuracy as well as the potential to improve the specificity of tissue identification and the precision of the subsequent treatment planning

  14. Effect of various commercially available mouthrinses on shear bond strength of orthodontic metal brackets: an in vitro study.

    Science.gov (United States)

    Meeran, Nazeer Ahmed; George, Ashwin Mathew

    2013-01-01

    Alcohol is known to degrade and dissolve the bisphenol A glycidyl methacrylate present in the composite resin. The effect of alcohol containing mouthrinses on the shear bond strength of orthodontic metal brackets bonded with composite resin has not been verified until date and is the purpose of this study. The aims and objectives of the present study were to evaluate (1) Whether there is a significant difference in the shear bond strength of metal orthodontic brackets after the 1 year (12 h) and 2 years simulation (24 h) of mouth rinsing with 4 different commercially available mouthrinses (2 alcoholic and 2 alcohol-free mouthrinses) when compared to the control. (2) Whether alcohol containing mouthrinses have more adverse effect on the shear bond strength when compared with alcohol-free mouthrinses. (3) To assess the site of bond failure using adhesive remnant index. Experimental - laboratory based. A total of 100 upper premolars extracted for orthodontic purpose were collected immediately after extraction, cleared soft-tissue debris and blood and immediately stored in distilled water with 0.1% thymol crystals added to inhibit bacterial growth. Two alcohol containing mouthrinses and two alcohol-free mouthrinses were used and the bonded teeth were placed in the mouthrinses for a stipulated period of time (1 year simulation and 2 years simulation) and shear bond strength were tested using Lloyd Universal Testing Machine. The data were analyzed using analysis of variance and paired samples t-test. After the 1 year and 2 years simulation time, samples stored in alcohol containing mouthrinses showed lower bond strength (P orthodontic brackets bonded with composite resin (Transbond XT in the present study), more when compared with alcohol-free mouthrinses. It is, therefore, highly advisable to avoid alcohol containing mouthrinses in patients undergoing orthodontic treatment and use alcohol-free mouthrinses as adjuncts to regular oral hygiene procedures for maintaining

  15. Feasibility of Commercially Available, Fully Automated Hepatic CT Volumetry for Assessing Both Total and Territorial Liver Volumes in Liver Transplantation

    Energy Technology Data Exchange (ETDEWEB)

    Shin, Cheong Il; Kim, Se Hyung; Rhim, Jung Hyo; Yi, Nam Joon; Suh, Kyung Suk; Lee, Jeong Min; Han, Joon Koo; Choi, Byung Ihn [Seoul National University Hospital, Seoul (Korea, Republic of)

    2013-02-15

    To assess the feasibility of commercially-available, fully automated hepatic CT volumetry for measuring both total and territorial liver volumes by comparing with interactive manual volumetry and measured ex-vivo liver volume. For the assessment of total and territorial liver volume, portal phase CT images of 77 recipients and 107 donors who donated right hemiliver were used. Liver volume was measured using both the fully automated and interactive manual methods with Advanced Liver Analysis software. The quality of the automated segmentation was graded on a 4-point scale. Grading was performed by two radiologists in consensus. For the cases with excellent-to-good quality, the accuracy of automated volumetry was compared with interactive manual volumetry and measured ex-vivo liver volume which was converted from weight using analysis of variance test and Pearson's or Spearman correlation test. Processing time for both automated and interactive manual methods was also compared. Excellent-to-good quality of automated segmentation for total liver and right hemiliver was achieved in 57.1% (44/77) and 17.8% (19/107), respectively. For both total and right hemiliver volumes, there were no significant differences among automated, manual, and ex-vivo volumes except between automate volume and manual volume of the total liver (p = 0.011). There were good correlations between automate volume and ex-vivo liver volume ({gamma}= 0.637 for total liver and {gamma}= 0.767 for right hemiliver). Both correlation coefficients were higher than those with manual method. Fully automated volumetry required significantly less time than interactive manual method (total liver: 48.6 sec vs. 53.2 sec, right hemiliver: 182 sec vs. 244.5 sec). Fully automated hepatic CT volumetry is feasible and time-efficient for total liver volume measurement. However, its usefulness for territorial liver volumetry needs to be improved.

  16. Feasibility of Commercially Available, Fully Automated Hepatic CT Volumetry for Assessing Both Total and Territorial Liver Volumes in Liver Transplantation

    International Nuclear Information System (INIS)

    Shin, Cheong Il; Kim, Se Hyung; Rhim, Jung Hyo; Yi, Nam Joon; Suh, Kyung Suk; Lee, Jeong Min; Han, Joon Koo; Choi, Byung Ihn

    2013-01-01

    To assess the feasibility of commercially-available, fully automated hepatic CT volumetry for measuring both total and territorial liver volumes by comparing with interactive manual volumetry and measured ex-vivo liver volume. For the assessment of total and territorial liver volume, portal phase CT images of 77 recipients and 107 donors who donated right hemiliver were used. Liver volume was measured using both the fully automated and interactive manual methods with Advanced Liver Analysis software. The quality of the automated segmentation was graded on a 4-point scale. Grading was performed by two radiologists in consensus. For the cases with excellent-to-good quality, the accuracy of automated volumetry was compared with interactive manual volumetry and measured ex-vivo liver volume which was converted from weight using analysis of variance test and Pearson's or Spearman correlation test. Processing time for both automated and interactive manual methods was also compared. Excellent-to-good quality of automated segmentation for total liver and right hemiliver was achieved in 57.1% (44/77) and 17.8% (19/107), respectively. For both total and right hemiliver volumes, there were no significant differences among automated, manual, and ex-vivo volumes except between automate volume and manual volume of the total liver (p = 0.011). There were good correlations between automate volume and ex-vivo liver volume (γ= 0.637 for total liver and γ= 0.767 for right hemiliver). Both correlation coefficients were higher than those with manual method. Fully automated volumetry required significantly less time than interactive manual method (total liver: 48.6 sec vs. 53.2 sec, right hemiliver: 182 sec vs. 244.5 sec). Fully automated hepatic CT volumetry is feasible and time-efficient for total liver volume measurement. However, its usefulness for territorial liver volumetry needs to be improved.

  17. Comparison of the Insecticidal Characteristics of Commercially Available Plant Essential Oils Against Aedes aegypti and Anopheles gambiae (Diptera: Culicidae).

    Science.gov (United States)

    Norris, Edmund J; Gross, Aaron D; Dunphy, Brendan M; Bessette, Steven; Bartholomay, Lyric; Coats, Joel R

    2015-09-01

    Aedes aegypti and Anopheles gambiae are two mosquito species that represent significant threats to global public health as vectors of Dengue virus and malaria parasites, respectively. Although mosquito populations have been effectively controlled through the use of synthetic insecticides, the emergence of widespread insecticide-resistance in wild mosquito populations is a strong motivation to explore new insecticidal chemistries. For these studies, Ae. aegypti and An. gambiae were treated with commercially available plant essential oils via topical application. The relative toxicity of each essential oil was determined, as measured by the 24-h LD(50) and percentage knockdown at 1 h, as compared with a variety of synthetic pyrethroids. For Ae. aegypti, the most toxic essential oil (patchouli oil) was ∼1,700-times less toxic than the least toxic synthetic pyrethroid, bifenthrin. For An. gambiae, the most toxic essential oil (patchouli oil) was ∼685-times less toxic than the least toxic synthetic pyrethroid. A wide variety of toxicities were observed among the essential oils screened. Also, plant essential oils were analyzed via gas chromatography/mass spectrometry (GC/MS) to identify the major components in each of the samples screened in this study. While the toxicities of these plant essential oils were demonstrated to be lower than those of the synthetic pyrethroids tested, the large amount of GC/MS data and bioactivity data for each essential oil presented in this study will serve as a valuable resource for future studies exploring the insecticidal quality of plant essential oils. © The Authors 2015. Published by Oxford University Press on behalf of Entomological Society of America. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  18. Experimental verification of lung dose with radiochromic film: comparison with Monte Carlo simulations and commercially available treatment planning systems

    International Nuclear Information System (INIS)

    Paelinck, L; Reynaert, N; Thierens, H; Neve, W De; Wagter, C de

    2005-01-01

    The purpose of this study was to assess the absorbed dose in and around lung tissue by performing radiochromic film measurements, Monte Carlo simulations and calculations with superposition convolution algorithms. We considered a layered polystyrene phantom of 12 x 12 x 12 cm 3 containing a central cavity of 6 x 6 x 6 cm 3 filled with Gammex RMI lung-equivalent material. Two field configurations were investigated, a small 1 x 10 cm 2 field and a larger 10 x 10 cm 2 field. First, we performed Monte Carlo simulations to investigate the influence of radiochromic film itself on the measured dose distribution when the film intersects a lung-equivalent region and is oriented parallel to the central beam axis. To that end, the film and the lung-equivalent materials were modelled in detail, taking into account their specific composition. Next, measurements were performed with the film oriented both parallel and perpendicular to the central beam axis to verify the results of our Monte Carlo simulations. Finally, we digitized the phantom in two commercially available treatment planning systems, Helax-TMS version 6.1A and Pinnacle version 6.2b, and calculated the absorbed dose in the phantom with their incorporated superposition convolution algorithms to compare with the Monte Carlo simulations. Comparing Monte Carlo simulations with measurements reveals that radiochromic film is a reliable dosimeter in and around lung-equivalent regions when the film is positioned perpendicular to the central beam axis. Radiochromic film is also able to predict the absorbed dose accurately when the film is positioned parallel to the central beam axis through the lung-equivalent region. However, attention must be paid when the film is not positioned along the central beam axis, in which case the film gradually attenuates the beam and decreases the dose measured behind the cavity. This underdosage disappears by offsetting the film a few centimetres. We find deviations of about 3.6% between

  19. Experimental verification of lung dose with radiochromic film: comparison with Monte Carlo simulations and commercially available treatment planning systems

    Science.gov (United States)

    Paelinck, L.; Reynaert, N.; Thierens, H.; DeNeve, W.; DeWagter, C.

    2005-05-01

    The purpose of this study was to assess the absorbed dose in and around lung tissue by performing radiochromic film measurements, Monte Carlo simulations and calculations with superposition convolution algorithms. We considered a layered polystyrene phantom of 12 × 12 × 12 cm3 containing a central cavity of 6 × 6 × 6 cm3 filled with Gammex RMI lung-equivalent material. Two field configurations were investigated, a small 1 × 10 cm2 field and a larger 10 × 10 cm2 field. First, we performed Monte Carlo simulations to investigate the influence of radiochromic film itself on the measured dose distribution when the film intersects a lung-equivalent region and is oriented parallel to the central beam axis. To that end, the film and the lung-equivalent materials were modelled in detail, taking into account their specific composition. Next, measurements were performed with the film oriented both parallel and perpendicular to the central beam axis to verify the results of our Monte Carlo simulations. Finally, we digitized the phantom in two commercially available treatment planning systems, Helax-TMS version 6.1A and Pinnacle version 6.2b, and calculated the absorbed dose in the phantom with their incorporated superposition convolution algorithms to compare with the Monte Carlo simulations. Comparing Monte Carlo simulations with measurements reveals that radiochromic film is a reliable dosimeter in and around lung-equivalent regions when the film is positioned perpendicular to the central beam axis. Radiochromic film is also able to predict the absorbed dose accurately when the film is positioned parallel to the central beam axis through the lung-equivalent region. However, attention must be paid when the film is not positioned along the central beam axis, in which case the film gradually attenuates the beam and decreases the dose measured behind the cavity. This underdosage disappears by offsetting the film a few centimetres. We find deviations of about 3.6% between

  20. 75 FR 81224 - Availability of Recreational Diving, Oil and Gas Operations and Commercial Fishing Seats for the...

    Science.gov (United States)

    2010-12-27

    ... Recreational Diving, Oil and Gas Operations and Commercial Fishing Seats for the Flower Garden Banks National... Service (NOS), National Oceanic and Atmospheric Administration (NOAA), Department of Commerce DOC). ACTION... seats on the Flower Garden Banks National Marine Sanctuary Advisory Council: Recreational Diving, Oil...

  1. Examination of commercially available copper oxide wire particles in combination with albendazole for control of gastrointestinal nematodes in lambs

    Science.gov (United States)

    Alternatives to synthetic anthelmintics remain critical due to the prevalence of anthelmintic resistance. The objective of the experiment was to determine the efficacy of copper oxide wire particles (COWP) from three commercial sources to control Haemonchus contortus in lambs. Naturally infected Ka...

  2. An Assessment of the Commercial Availability of Carbon Dioxide Capture and Storage Technologies as of June 2009

    Energy Technology Data Exchange (ETDEWEB)

    Dooley, James J.; Davidson, Casie L.; Dahowski, Robert T.

    2009-06-26

    Currently, there is considerable confusion within parts of the carbon dioxide capture and storage (CCS) technical and regulatory communities regarding the maturity and commercial readiness of the technologies needed to capture, transport, inject, monitor and verify the efficacy of carbon dioxide (CO2) storage in deep, geologic formations. The purpose of this technical report is to address this confusion by discussing the state of CCS technological readiness in terms of existing commercial deployments of CO2 capture systems, CO2 transportation pipelines, CO2 injection systems and measurement, monitoring and verification (MMV) systems for CO2 injected into deep geologic structures. To date, CO2 has been captured from both natural gas and coal fired commercial power generating facilities, gasification facilities and other industrial processes. Transportation via pipelines and injection of CO2 into the deep subsurface are well established commercial practices with more than 35 years of industrial experience. There are also a wide variety of MMV technologies that have been employed to understand the fate of CO2 injected into the deep subsurface. The four existing end-to-end commercial CCS projects – Sleipner, Snøhvit, In Salah and Weyburn – are using a broad range of these technologies, and prove that, at a high level, geologic CO2 storage technologies are mature and capable of deploying at commercial scales. Whether wide scale deployment of CCS is currently or will soon be a cost-effective means of reducing greenhouse gas emissions is largely a function of climate policies which have yet to be enacted and the public’s willingness to incur costs to avoid dangerous anthropogenic interference with the Earth’s climate. There are significant benefits to be had by continuing to improve through research, development, and demonstration suite of existing CCS technologies. Nonetheless, it is clear that most of the core technologies required to address capture, transport

  3. Study of essential and non essential elements in cereal - based weaning foods for infants commercially available on the Ghanaian market

    International Nuclear Information System (INIS)

    Bawol, S.

    2013-07-01

    Cereal-based weaning foods, which abound on the Ghanaian markets are nutritionally vital in the growth and developments of infants. Recent report in scientific literature however indicates that rice and other cereals used in the manufacturing of the weaning foods contribute significantly to the intake of arsenic (As) cadmium (Cd) and lead (Pb) by infants. In view of this, frequent monitoring of the cereal -based weaning foods has become imperative. The study assessed the beneficial health effects and risks posed by consumption of cereal - based weaning foods commercially available on the Ghanaian market with respect to the essential elements (Ca, Cl, Cr, Cu, Fe, K, Mg, Mn, Na, Se, V and Zn) and, non-essential, potentially toxic elements (As, Br, Hg, Pb,and Sn). Twenty (20) different brands of weaning foods were purchased from various retail outlets in Accra and used for the study. Instrumental neutron activation analysis (INAA) and atomic absorption spectrometry [with flame atomisation (FAAS) and hydride generation (HGAAS)] were used in analysing the samples. Determination of Pb using FAAS was done following its extraction with dithizone. The analytical methods were validated using certified reference materials NIST 1568a (Rice flour) and NIST 1547 (Peach leaves). The levels (μg/g, in ranges) obtained for the elements were: As (<0.025), Br (<0.17-402), Ca (405-2002), Cl (158-5521), and Cr (<0.03-1.23). Others are Cu(0.83-55.80), Fe (1.07-11.78), Hg (<0.025), and K (49-3845) Mg (20-280) and Mn (0.84-38.94). The rest include: Na (13-1588), Pb (0.025-0.093), Se (0.145-0.317), Sn (35.8-91.8), V (<0.01-0.990) and Zn (0.50-7.17). The daily intakes of the essential elements were also estimated, and generally found to be lower than recommended values set either by the FAO/WHO, the European Food Safety Authority (EFSA), the US Food and Nutrition Board, or the Joint Societies for Nutrition of Germany, Austria and Switzerland. The estimated intake levels of the non

  4. Stability, protein binding and clearance studies of [99mTc]DTPA. Evaluation of a commercially available dry-kit

    DEFF Research Database (Denmark)

    Rehling, M

    1988-01-01

    [99mTc]DTPA has achieved widespread use for the measurement of glomerular filtration rate (GFR) with the single injection plasma clearance technique and for gamma-camera renography. However, the quality of the commercial preparations varies. The purpose of the present investigation was to study...... the quality of a commercial [99mTc]DTPA preparation (C.I.S., France) with reference to stability, protein binding and accuracy of the determined plasma clearance values as a measure of GFR. The stability of the preparations was studied by thin-layer chromatography, the in vitro protein binding by Sephadex.......7% and 1.1%, respectively. The plasma clearance of [99mTc]DTPA was on an average 3.7% higher than that of [51Cr]EDTA in 27 patients. It is concluded that the [99mTc]DTPA preparation is reliable for the measurement of GFR. The preparation is stable for at least six hours at room temperature...

  5. Preliminary evaluation of a commercially available videogame system as an adjunct therapeutic intervention for improving balance among children and adolescents with lower limb amputations.

    Science.gov (United States)

    Andrysek, Jan; Klejman, Susan; Steinnagel, Bryan; Torres-Moreno, Ricardo; Zabjek, Karl F; Salbach, Nancy M; Moody, Kim

    2012-02-01

    To examine the safety, feasibility, and balance performance effects of a 4-week home-based balance therapy program using a commercially available videogame system. A pilot study involving a preintervention and postintervention design was conducted with measurements taken at baseline, immediately postintervention (week 5), and at follow-up (week 13) for retention. University hospital outpatient clinic and participants' places of residence. Children and adolescents with unilateral lower limb amputation (n=6; 3 transfemoral [TF] and 3 Van Ness) and age-matched, typically developing individuals (n=10) for baseline comparison. Two videogames involving weight shifting in standing were each played at home for 20 min/d, 4d/wk for a period of 4 weeks. A physical therapist provided initial instruction and monitoring. Postural control characteristics using center of pressure (COP) displacements during quiet standing; functional balance using the Community Balance and Mobility Scale (CB&M); and compliance, safety, and feasibility using custom questionnaires. Average playing times for the first 3 weeks ranged from 16.0 to 21.1 minutes for the 2 games. At baseline, the children and adolescents with TF amputation had substantially greater COP displacements than the Van Ness group and typically developing children and adolescents. Immediately postintervention, the COP displacements decreased in the TF amputees, resulting in values that were closer to those of the typically developing children. The average increase in CB&M score from baseline to follow-up was 6 points across participants. In-home, videogame-based balance training therapies can achieve excellent compliance in children and adolescents with lower limb amputation. With proper instructions and monitoring, the therapeutic intervention can be safely administered. Some improvements in postural control characteristics were seen in children and adolescents with balance deficits immediately postintervention, but long

  6. A comparative study of antiplaque and antigingivitis effects of herbal mouthrinse containing tea tree oil, clove, and basil with commercially available essential oil mouthrinse

    Directory of Open Access Journals (Sweden)

    Shaila V. Kothiwale

    2014-01-01

    Full Text Available Background: The relatively safe nature and cost-effectiveness of herbal extracts have led to a resurgent interest in their utility as therapeutic agents. Therefore, this prospective, double-blind, randomly controlled clinical trial was designed to compare the antiplaque and antigingivitis effects of newly formulated mouthrinse containing tea tree oil (TTO, clove, and basil with those of commercially available essential oil (EO mouthrinse. Materials and Methods: Forty patients were selected for a 21-day study period and randomly divided into two groups. The test group patients were given newly formulated herbal mouthrinse and the control group patients were given commercially available EO mouthrinse. The Plaque Index (PI, Gingival Index (GI, and Papillary Marginal Attachment (PMA Index were recorded at baseline, 14 days, and 21 days. The microbial colony forming units (CFU were assessed at baseline and 21 days. Results: Test group patients using herbal mouthrinse showed significant improvement in GI (0.16, PI (0.57, and PMA (0.02 scores. These improvements were comparable to those achieved with commercially available EO mouthrinse. However, the aerobic and anaerobic CFU of microbiota were reduced with the herbal mouthrinse (P = 0.0000. Conclusion: The newly formulated herbal mouthrinse and commercially available mouthrinse were beneficial clinically as antiplaque and antigingivitis agents. Newly formulated mouthrinses showed significant reduction in microbial CFU at 21 days. So, our findings support the regular use of herbal mouthrinse as an antiplaque, antigingivitis, and antimicrobial rinse for better efficacy.

  7. Comparative efficacy of four commercially available heartworm preventive products against the MP3 laboratory strain of Dirofilaria immitis.

    Science.gov (United States)

    Blagburn, B L; Dillon, A R; Arther, R G; Butler, J M; Newton, J C

    2011-03-10

    A controlled laboratory study was conducted to evaluate the efficacy of four commercial products administered as a single treatment for the prevention of heartworm disease caused by Dirofilaria immitis in dogs. Forty-four commercially sourced Beagle dogs, 6-7 months of age, were received at the test site (Auburn University, Department of Pathobiology) on Study Day (SD) -72 to begin acclimation. On SD -30, each dog was inoculated subcutaneously with 100 infective, third-stage D. immitis larvae (MP3 strain, TRS Laboratories, Inc., Athens, GA). On SD -1, 40 dogs weighing 18.2-25.3 lbs were ranked by decreasing body weight and randomized to five groups of eight dogs each. On SD 0, the dogs assigned to Group 1 were treated orally with ivermectin/pyrantel pamoate chewable tablets, Group 2 dogs were treated orally with milbemycin oxime flavored tablets, Group 3 dogs were treated with selamectin topical solution, and Group 4 dogs were treated with imidacloprid/moxidectin topical solution. Group 5 dogs remained nontreated. Dosages for dogs in Groups 1-4 were based on the individual body weight of each dog and current labeled dose banding for each commercial product. All dogs were fasted overnight prior to treatment. Food was returned four hours after treatment. Animals were observed for abnormal clinical signs involving eyes, feces, respiration, behavioral attitude, locomotion/musculature, or skin conditions at prescribed intervals immediately after treatment and at twice daily intervals thereafter. On SD 90, whole blood was collected and tested for adult heartworm antigen. On SDs 119/120, the dogs were euthanized and subjected to necropsy examination for recovery of adult D. immitis and/or worm fragments. At necropsy, all 8 dogs in the nontreated group were infected with adult D. immitis (34-70 worms/dog, geometric mean (GM)=51.6 worms/dog). One or more adult D. immitis and/or worm fragments were recovered from 7 of 8 of the dogs each in Groups 1-3 (87.5% were heartworm

  8. Evaluation of a commercially available enzyme-linked immunosorbent assay for the diagnosis of canine sarcoptic mange.

    Science.gov (United States)

    Curtis, C F

    2001-02-24

    This study was designed to assess the accuracy of a commercial enzyme-linked immunosorbent assay for the diagnosis of canine scabies. Serum samples from 37 dogs were examined blind; 12 had sarcoptic mange confirmed by the identification of mites in skin scrapings, 12 were atopic (with positive intradermal reactions to one or more aeroallergens, including Dermatophagoides farinae), and 13 were healthy dogs with no history of skin disease. Optical density values of more than 0.16 were considered positive, 0.145 to 0.16 were considered questionable and less than 0.145 were considered negative. Ten of the 12 dogs with scabies were positive, all 12 atopic dogs were negative, and 11 of the 13 healthy dogs were negative and two were questionable.

  9. Comparing the Effects of Commercially Available and Custom-Made Video Prompting for Teaching Cooking Skills to High School Students with Autism

    Science.gov (United States)

    Mechling, Linda C.; Ayres, Kevin M.; Foster, Ashley L.; Bryant, Kathryn J.

    2013-01-01

    The study compared the effects of using commercially available and custom-made video prompts on the completion of cooking recipes by four high school age males with a diagnosis of autism. An adapted alternating treatments design with continuous baseline, comparison, final treatment, and best treatment condition was used to compare the two…

  10. Assessing the Content and Quality of Commercially Available Reading Software Programs: Do They Have the Fundamental Structures to Promote the Development of Early Reading Skills in Children?

    Science.gov (United States)

    Grant, Amy; Wood, Eileen; Gottardo, Alexandra; Evans, Mary Ann; Phillips, Linda; Savage, Robert

    2012-01-01

    The current study developed a taxonomy of reading skills and compared this taxonomy with skills being trained in 30 commercially available software programs designed to teach emergent literacy or literacy-specific skills for children in preschool, kindergarten, and Grade 1. Outcomes suggest that, although some skills are being trained in a…

  11. ESTIMATION OF pH, TOTAL ACID AND ETHANOL CONTENT OF COMMERCIALLY AVAILABLE ALCOHOL-CONTAINING MOUTHWASHES AND ITS EFFECT ON SALIVARY pH

    OpenAIRE

    Rafi Shaik; Sharath Pocha Reddy; Sameeulla Shaik; Sarah Emerald Sheela Nemalladinne; Dandu Sivasai Prasad Reddy; Kotu Nagavenkata Sai Praveen

    2017-01-01

    BACKGROUND Use of mouthwash has become widespread as a part of routine oral hygiene. Mouthwashes may have deleterious effects on oral tissues because of its low pH, high acid content and use of ethanol as an antiseptic agent. MATERIALS AND METHODS A cross-sectional experimental study was conducted among 48 undergraduate dental students. Eight commercially available alcohol-containing mouthwashes, which are available in Indian market were selected for which the pH, total acid an...

  12. An Examination of How the Availability of State-backed Terrorism Insurance Programs and Commercial Terrorism Insurance Affects the Operational Decisions of Multinational Companies.

    OpenAIRE

    GREY, William / WJG

    2011-01-01

    This dissertation explores the extent to which the operational decisions of multinational companies (MNCs) are affected by the availability of State-backed terrorism insurance programs and commercial terrorism insurance. The initial hypothesis made is that MNCs will be reluctant to invest in zones or countries with high terrorism or political risks, especially when insurance for these risks may be limited or unavailable. This investigation finds that the availability of State-backed terrorism...

  13. To Evaluate Effect of Airborne Particle Abrasion using Different Abrasives Particles and Compare Two Commercial Available Zirconia on Flexural Strength on Heat Treatment

    Science.gov (United States)

    Prasad, Hari A.; Pasha, Naveed; Hilal, Mohammed; Amarnath, G. S.; Kundapur, Vinaya; Anand, M; Singh, Sumeet

    2017-01-01

    abrasion followed by the heat treatment reduces the fracture strength of the specimen than that ofthe group treated only by the air abrasives. The fracture strength of a commercially available Ceramill (AMANNGIRRBACH) is greater than that of a Zirconia from ZR-White (UPCERA) variety. PMID:28824346

  14. Comparison of microbially enhanced compost extracts produced from composted cattle rumen content material and from commercially available inocula.

    Science.gov (United States)

    Shrestha, Karuna; Adetutu, Eric M; Shrestha, Pramod; Walsh, Kerry B; Harrower, Keith M; Ball, Andrew S; Midmore, David J

    2011-09-01

    A comparative study was performed on compost extracts prepared from cattle rumen content composted for three and nine months, nine month old compost inoculated with a Nutri-Life 4/20™ inoculum, and two commercial preparations (LivingSoil™ and Nutri-Life 4/20™), all incubated for 48h. Nutri-Life 4/20™ had the highest concentrations of NO(3)(-)-N and K(+)-K, while rumen compost extract had higher humic and fulvic acids concentration. The bacterial and fungal community level functional diversity of three month old compost extract and of LivingSoil™, assessed with Biolog™, were higher than that of nine month old rumen compost extract, with or without Nutri-Life 4/20™ inoculum, or Nutri-Life 4/20™. No difference in fungal diversity was observed between treatments, as indicated by Denaturing Gradient Gel Electrophoresis (DGGE) analysis, however, bacterial diversity was higher in all compost extracts and LivingSoil™ compared to the Nutri-Life 4/20™. Criteria for judging the quality of a microbially enhanced extract are discussed. Copyright © 2011 Elsevier Ltd. All rights reserved.

  15. Isotopic characterization as a screening tool in authentication of organic produce commercially available in western North America.

    Science.gov (United States)

    Verenitch, Sergei; Mazumder, Asit

    2015-01-01

    The use of nitrogen stable isotopes to discriminate between conventionally and organically grown crops has been further developed in this study. Soil and irrigation water from different regions, as well as nitrogen fertilizers used, have been examined in detail to determine their effects on nitrogen isotope composition of spinach, lettuce, broccoli and tomatoes. Over 1000 samples of various types of organically and conventionally grown produce of known origin, along with the samples of nitrogen fertilizers used for their growth, have been analysed in order to assemble the datasets of crop/fertilizer correlations. The results demonstrate that the developed approach can be used as a valuable component in the verification of agricultural practices for more than 25 different types of commercially grown green produce, either organic or conventional. Over a period of two years, various organic and non-organic greens, from different stores in Seattle (WA, USA) and Victoria (BC, Canada), were collected and analysed using this methodology with the objective of determining any pattern of misrepresentation.

  16. If we offer it, will children buy it? Sales of healthy foods mirrored their availability in a community sport, commercial setting in Alberta, Canada.

    Science.gov (United States)

    Olstad, Dana Lee; Goonewardene, Laksiri A; McCargar, Linda J; Raine, Kim D

    2015-04-01

    Community sports settings are often sources of unhealthy foods for children. Many managers in these settings are reluctant to increase availability of healthy food options because they perceive that healthy foods are not profitable. This study assessed the independent contribution of increased availability of healthy foods to their sales in a community sport, commercial context. Change in revenues per patron was also examined. The availability of healthy items was increased from 9.1% at baseline (35 days) to 25.0% during the intervention period (40 days), returning to 9.1% postintervention (6 days). Purchases of all patrons who bought foods/beverages (n=17,262 items sold) from two concessions at an outdoor community pool were assessed from baseline to postintervention. Chi-square analyses assessed differences in the proportion of healthy and unhealthy items sold, as well as in the proportion of total revenues per patron across periods. A trained observer also recorded qualitative observations pertaining to a subset of patrons' (n=221) dietary behaviors and activities. Healthy items represented 7.7%, 22.7%, and 9.8% of sales during the preintervention, intervention, and postintervention periods, respectively (ppatron did not differ by period. Food availability was an important environmental determinant of food purchasing behaviors in this community commercial context, given that sales of healthy foods closely mirrored their availability. Increased availability of healthy foods in community and commercial settings is important because concurrent changes within multiple environments will be required to improve children's dietary behaviors.

  17. Commercial breakfast cereals available in Mexican markets and their contribution in dietary fiber, β-glucans and protein quality by rat bioassays.

    Science.gov (United States)

    Falcón-Villa, María R; Barrón-Hoyos, Jesús M; Cinco-Moroyoqui, Francisco J

    2014-09-01

    The beneficial effect of dietary fiber (DF) consumption has long been recognized. The global economy and open market trade policies have increased the availability of food products in Mexican markets, resulting in a wide variety of ready-to-eat commercial breakfast cereals classified as 'high fiber'. This research was aimed to evaluate the total dietary fiber contents, its fractions (soluble and insoluble) and β-glucan in 13 commercial 'high-fiber' breakfast cereals, as well as to evaluate their protein quality by rat bioassays. Commercial 'high-fiber' breakfast cereals had 7.42-39.82% insoluble dietary fiber, 2.53-12.85% soluble dietary fiber, and 0.45-4.96% β-glucan. These ready-to-eat commercial 'high-fiber' breakfast cereals differed significantly in their total dietary fiber, their soluble and insoluble DF fractions, and also in their β-glucan contents. When supplied as experimental diets, in 14-day rat feeding trials, the 'high-fiber' breakfast cereals showed an adverse effect on the % N digestibility but protein utilization, as measured as net protein ratio (NPR), was not significantly affected. The consumption of these commercial breakfast cereals, especially those made of oats as the basic ingredient, is highly recommended, since these products, being a concentrated source of dietary fiber, do not affect their protein quality.

  18. Prevalence and molecular characterization of Staphylococcus aureus in commercially available meat over a one-year period in Iowa, USA.

    Science.gov (United States)

    Thapaliya, Dipendra; Forshey, Brett M; Kadariya, Jhalka; Quick, Megan K; Farina, Sarah; O' Brien, Ashley; Nair, Rajeshwari; Nworie, Amos; Hanson, Blake; Kates, Ashley; Wardyn, Shylo; Smith, Tara C

    2017-08-01

    Methicillin-resistant Staphylococcus aureus (MRSA) is a leading cause of infectious disease morbidity and mortality. Previous studies have confirmed the presence of S. aureus, including MRSA, on raw meat products. We investigated the prevalence and molecular epidemiology of S. aureus and MRSA in commercially-distributed antibiotic-free and conventional raw meat products (n = 3290) purchased in 8 Iowa retail stores weekly for a period of one year. Isolates were characterized using spa typing, and PCR was used to detect the presence of the Panton-Valentine leukocidin (PVL) and mecA genes. Quantitation of S. aureus on meat products was carried out one week per month. The prevalence of S. aureus on meat samples was 27.8% (913/3290). Compared to antibiotic-free meat samples, higher prevalence of both MRSA and methicillin-susceptible S. aureus (MSSA) were found in conventional meat samples. Among the S. aureus isolates, 18 were PVL-positive (1.9%) and 41 (4.5%) carried mecA. Phenotypic oxacillin resistance was observed for 17.1% (41/239) of the isolates tested, while 23% (55/239) were multi-drug resistant. A total of 132 spa types were detected from 913 contaminated meat samples. Overall, t002 was the most common spa type identified (137; 15.0%). The number of colony-forming units (CFU) per 10 g meat ranged from 2 to 517 (median: 8 CFU per 10 g of meat; mean: 28) with the highest bacterial load observed on turkey samples. These data reinforce the need to consider meat products as potential vehicles of S. aureus transmission from farm into human households, and the potential need for public health intervention programs pre and post-slaughter in meat processing facilities. Copyright © 2017 Elsevier Ltd. All rights reserved.

  19. Ability of commercially available dairy ration programs to predict duodenal flows of protein and essential amino acids in dairy cows.

    Science.gov (United States)

    Pacheco, D; Patton, R A; Parys, C; Lapierre, H

    2012-02-01

    The objective of this analysis was to compare the rumen submodel predictions of 4 commonly used dairy ration programs to observed values of duodenal flows of crude protein (CP), protein fractions, and essential AA (EAA). The literature was searched and 40 studies, including 154 diets, were used to compare observed values with those predicted by AminoCow (AC), Agricultural Modeling and Training Systems (AMTS), Cornell-Penn-Miner (CPM), and National Research Council 2001 (NRC) models. The models were evaluated based on their ability to predict the mean, their root mean square prediction error (RMSPE), error bias, and adequacy of regression equations for each protein fraction. The models predicted the mean duodenal CP flow within 5%, with more than 90% of the variation due to random disturbance. The models also predicted within 5% the mean microbial CP flow except CPM, which overestimated it by 27%. Only NRC, however, predicted mean rumen-undegraded protein (RUP) flows within 5%, whereas AC and AMTS underpredicted it by 8 to 9% and CPM by 24%. Regarding duodenal flows of individual AA, across all diets, CPM predicted substantially greater (>10%) mean flows of Arg, His, Ile, Met, and Lys; AMTS predicted greater flow for Arg and Met, whereas AC and NRC estimations were, on average, within 10% of observed values. Overpredictions by the CPM model were mainly related to mean bias, whereas the NRC model had the highest proportion of bias in random disturbance for flows of EAA. Models tended to predict mean flows of EAA more accurately on corn silage and alfalfa diets than on grass-based diets, more accurately on corn grain-based diets than on non-corn-based diets, and finally more accurately in the mid range of diet types. The 4 models were accurate at predicting mean dry matter intake. The AC, AMTS, and NRC models were all sufficiently accurate to be used for balancing EAA in dairy rations under field conditions. Copyright © 2012 American Dairy Science Association

  20. 75 FR 6169 - Request for Public Comment on a Commercial Availability Request Under the U.S.-Singapore Free...

    Science.gov (United States)

    2010-02-08

    ... Availability Request Under the U.S.-Singapore Free Trade Agreement February 2, 2010. AGENCY: Committee for the... modification of the U.S.-Singapore Free Trade Agreement (USSFTA) rules of origin for certain apparel articles... of Singapore for consultations under Article 3.18.4(a)(i) of the USSFTA. Singapore is seeking...

  1. Home energy management (HEM database: A list with coded attributes of 308 devices commercially available in the US

    Directory of Open Access Journals (Sweden)

    Marco Pritoni

    2018-02-01

    Full Text Available Policymakers worldwide are currently discussing whether to include home energy management (HEM products in their portfolio of technologies to reduce carbon emissions and improve grid reliability. However, very little data is available about these products. Here we present the results of an extensive review including 308 HEM products available on the US market in 2015–2016. We gathered these data from publicly available sources such as vendor websites, online marketplaces and other vendor documents. A coding guide was developed iteratively during the data collection and utilized to classify the devices. Each product was coded based on 96 distinct attributes, grouped into 11 categories: Identifying information, Product components, Hardware, Communication, Software, Information - feedback, Information - feedforward, Control, Utility interaction, Additional benefits and Usability. The codes describe product features and functionalities, user interaction and interoperability with other devices. A mix of binary attributes and more descriptive codes allow to sort and group data without losing important qualitative information. The information is stored in a large spreadsheet included with this article, along with an explanatory coding guide. This dataset is analyzed and described in a research article entitled “Categories and functionality of smart home technology for energy management” (Ford et al., 2017 [1]. Keywords: Home energy management, Energy efficiency, Smart home, Home automation, Internet of things

  2. Comparison of non-invasive individual monitoring of the training and health of athletes with commercially available wearable technologies

    Directory of Open Access Journals (Sweden)

    Peter eDüking

    2016-03-01

    Full Text Available Athletes adapt their training daily to optimize performance, as well as avoid fatigue, overtraining and other undesirable effects on their health. To optimize training load, each athlete must take his/her own personal objective and subjective characteristics into consideration and an increasing number of wearable technologies (wearables provide convenient monitoring of various parameters. Accordingly, it is important to help athletes decide which parameters are of primary interest and which wearables can monitor these parameters most effectively. Here, we discuss the wearable technologies available for non-invasive monitoring of various parameters concerning an athlete’s training and health. On the basis of these considerations, we suggest directions for future development. Furthermore, we propose that a combination of several wearables is most effective for accessing all relevant parameters, disturbing the athlete as little as possible, and optimizing performance and promoting health.

  3. Radionuclide content in laundry detergents commercially available on the Serbian market and assessment of radiological environmental hazards

    Directory of Open Access Journals (Sweden)

    Vukanac Ivana S.

    2017-01-01

    Full Text Available Laundry detergents are chemicals widely used in everyday life, and in numerous industry branches. In order to perceive the radiological aspect of environmental pollution by wastewater, the analysis of laundry detergents available on the Serbian market was undertaken. Laundry detergent samples were measured by means of gamma spectrometry and the results are presented in this paper. Analysis of the obtained activity concentrations showed that laundry detergents in Serbia mostly fulfill the international recommendation and requirements regarding the phosphate content. Besides that, the content of the detected radionuclides in laundry detergent samples indicates the minor radiological risk to the environment via wastewaters. [Project of the Serbian Ministry of Education, Science and Technological Development, Grant no. 171018

  4. Home energy management (HEM) database: A list with coded attributes of 308 devices commercially available in the US.

    Science.gov (United States)

    Pritoni, Marco; Ford, Rebecca; Karlin, Beth; Sanguinetti, Angela

    2018-02-01

    Policymakers worldwide are currently discussing whether to include home energy management (HEM) products in their portfolio of technologies to reduce carbon emissions and improve grid reliability. However, very little data is available about these products. Here we present the results of an extensive review including 308 HEM products available on the US market in 2015-2016. We gathered these data from publicly available sources such as vendor websites, online marketplaces and other vendor documents. A coding guide was developed iteratively during the data collection and utilized to classify the devices. Each product was coded based on 96 distinct attributes, grouped into 11 categories: Identifying information, Product components, Hardware, Communication, Software, Information - feedback, Information - feedforward, Control, Utility interaction, Additional benefits and Usability. The codes describe product features and functionalities, user interaction and interoperability with other devices. A mix of binary attributes and more descriptive codes allow to sort and group data without losing important qualitative information. The information is stored in a large spreadsheet included with this article, along with an explanatory coding guide. This dataset is analyzed and described in a research article entitled "Categories and functionality of smart home technology for energy management" (Ford et al., 2017) [1].

  5. Analytical Studies on the Quality and Environmental Impact of Commercial Motor Gasoline Available in Multan Region of Pakistan

    Directory of Open Access Journals (Sweden)

    Ghulam Yasin

    2008-12-01

    Full Text Available Physico-chemical characteristics such as specific gravity, reid vapour pressure, copper corrosion, distillation (I.B.P., F.B.P., Total recovery & residue and hydrocarbon contents (saturates, aromatics and polars of gasoline of different oil marketing companies collected from retail outlets in district Multan have been analysed using standard ASTM procedures. Results have been compared with the Pakistani, Indian and European specifications to assess the quality of Pakistani gasoline (petrol. The environmental impact of gasoline has also been assessed.

  6. Energy compensation in the real world. Good compensation for small portions of chocolate and biscuits over short time periods in complicit consumers using commercially available foods.

    OpenAIRE

    Appleton, Katherine; McKeown, P.P.; Woodside, J.V.

    2014-01-01

    While investigations using covert food manipulations tend to suggest that individuals are poor at adjusting for previous energy intake, in the real world adults rarely consume foods with which they are ill-informed. This study investigated the impact in fully complicit consumers of consuming commercially available dark chocolate, milk chocolate, sweet biscuits and fruit bars on subsequent appetite. Using a repeated measures design, participants received four small portions (4 × 10-11 g) of ei...

  7. Quantitative comparison and evaluation of two commercially available, two-dimensional electrophoresis image analysis software packages, Z3 and Melanie.

    Science.gov (United States)

    Raman, Babu; Cheung, Agnes; Marten, Mark R

    2002-07-01

    While a variety of software packages are available for analyzing two-dimensional electrophoresis (2-DE) gel images, no comparisons between these packages have been published, making it difficult for end users to determine which package would best meet their needs. The goal here was to develop a set of tests to quantitatively evaluate and then compare two software packages, Melanie 3.0 and Z3, in three of the fundamental steps involved in 2-DE image analysis: (i) spot detection, (ii) gel matching, and (iii) spot quantitation. To test spot detection capability, automatically detected protein spots were compared to manually counted, "real" protein spots. Spot matching efficiency was determined by comparing distorted (both geometrically and nongeometrically) gel images with undistorted original images, and quantitation tests were performed on artificial gels with spots of varying Gaussian volumes. In spot detection tests, Z3 performed better than Melanie 3.0 and required minimal user intervention to detect approximately 89% of the actual protein spots and relatively few extraneous spots. Results from gel matching tests depended on the type of image distortion used. For geometric distortions, Z3 performed better than Melanie 3.0, matching 99% of the spots, even for extreme distortions. For nongeometrical distortions, both Z3 and Melanie 3.0 required user intervention and performed comparably, matching 95% of the spots. In spot quantitation tests, both Z3 and Melanie 3.0 predicted spot volumes relatively well for spot ratios less than 1:6. For higher ratios, Melanie 3.0 did much better. In summary, results suggest Z3 requires less user intervention than Melanie 3.0, thus simplifying differential comparison of 2-DE gel images. Melanie 3.0, however, offers many more optional tools for image editing, spot detection, data reporting and statistical analysis than Z3. All image files used for these tests and updated information on the software are available on the internet

  8. Analysis of Canadian and Irish forage, oats and commercially available equine concentrate feed for pathogenic fungi and mycotoxins

    Directory of Open Access Journals (Sweden)

    Buckley Thomas

    2007-04-01

    Full Text Available Abstract Respiratory infections, recurrent airway obstruction (RAO and exercise induced pulmonary haemorrhage (EIPH are major causes of poor performance in horses. Fungi and mycotoxins are now recognised as a major cause of these conditions. The most notable fungi are Aspergillus and Fusarium. Fungal spores can originate from forage, bedding and feed and, in turn, these fungal spores can produce a series of mycotoxins as secondary metabolites. This study set out to ascertain the degree of fungal and mycotoxin contamination in feed and fodder used in Irish racing yards over a one-year period. Weather conditions in forage producing areas were sampled by Met Eireann and the Canadian Meteorological Service. Fifty per cent of Irish hay, 37% of haylage and 13% of Canadian hay contained pathogenic fungi. Of the mycotoxins, T2 and zearalenone were most prominent. Twenty-one per cent of Irish hay and 16% of pelleted feed contained zearalenone. Forty per cent of oats and 54% of pelleted feed contained T2 toxins.

  9. The Effect of Specimen Size on the Results of Concrete Adiabatic Temperature Rise Test with Commercially Available Equipment

    Directory of Open Access Journals (Sweden)

    Byung Jae Lee

    2014-12-01

    Full Text Available In this study, adiabatic temperature rise tests depending on binder type and adiabatic specimen volume were performed, and the maximum adiabatic temperature rises and the reaction factors for each mix proportion were analyzed and suggested. The results indicated that the early strength low heat blended cement mixture had the lowest maximum adiabatic temperature rise (Q∞ and the ternary blended cement mixture had the lowest reaction factor (r. Also, Q and r varied depending on the adiabatic specimen volume even when the tests were conducted with a calorimeter, which satisfies the recommendations for adiabatic conditions. Test results show a correlation: the measurements from the 50 L specimens were consistently higher than those from the 6 L specimens. However, the Q∞ and r values of the 30 L specimen were similar to those of the 50 L specimen. Based on the above correlation, the adiabatic temperature rise of the 50 L specimen could be predicted using the results of the 6 L and 30 L specimens. Therefore, it is thought that this correlation can be used for on-site concrete quality control and basic research.

  10. Speciation study of the heavy metals in commercially available recharge cards coatings in Nigeria and the health implication

    Directory of Open Access Journals (Sweden)

    Abolanle S. Adekunle

    2014-01-01

    Full Text Available This work assessed levels of heavy metals exposure from silver coatings of mobile phones recharge cards of three major companies (designated as A, B and C with price denominations 100, 200 and 400 from companies A, B and C respectively, which were carefully scratched using a plastic scraper into a glass tube. The coatings were acid digested for total metal concentration, while speciation experiment for Mn, Cu, Cd and Pb was carried out. Total metals and speciation analysis were done using AAS and XRF techniques. The total metal concentration from XRF analysis was in the range: Ca (70–2140 μg/g, K (20–4930 μg/g, Sc (80–270 μg/g, Ti (1530–12,580 μg/g, Fe (50–6660 μg/g, Ni (20–2040 μg/g, Cu (20–850 μg/g and Zn (40–460 μg/g. Cr had the lowest concentration (10 μg/g in A (400 while Ti had the highest concentration (12,580 μg/g in C (500 for all the coatings analyzed. AAS and XRF results agreed closely except for Fe with higher concentration. A (100 contained high concentration of the metals compared with others. Speciation study identified Mn as the most mobile element when present in the environment.

  11. Evaluation of Anticancer and Antioxidant Activity of a Commercially Available CO2 Supercritical Extract of Old Man's Beard (Usnea barbata.

    Directory of Open Access Journals (Sweden)

    Ana Zugic

    Full Text Available There is a worldwide ongoing investigation for novel natural constituents with cytotoxic and antioxidant properties. The aim of this study was to investigate chemical profile and stated biological activities of the supercritical CO2 extract (SCE of old man's beard compared to the extracts obtained using the conventional techniques (Soxhlet extracts and macerate. The most abundant compound identified was usnic acid, which content was inversely proportional to the polarity of the solvent used and was the highest in the SCE, which was the sample revealing the highest cytotoxic activity in tested tumor cell lines (B16 mouse melanoma and C6 rat glioma, with lower IC50 values compared to pure usnic acid. Further investigations suggested both SCE and usnic acid to induce apoptosis and/or autophagy in B16 and C6, indicating higher cytotoxicity of SCE to be related to the higher degree of ROS production. A good correlation of usnic acid content in the extracts and their antioxidant capacity was established, extricating SCE as the most active one. Presented results support further investigations of SCE of old man's beard as a prospective therapeutic agent with potential relevance in the treatment of cancer and/or in oxidative stress-mediated conditions.

  12. Detection of highly toxic elements (lead and chromium) in commercially available eyeliner (kohl) using laser induced break down spectroscopy

    Science.gov (United States)

    Gondal, M. A.; Dastageer, M. A.; Al-Adel, F. F.; Naqvi, A. A.; Habibullah, Y. B.

    2015-12-01

    A sensitive laser induced breakdown spectroscopic system was developed and optimized for using it as a sensor for the detection of trace levels of lead and chromium present in the cosmetic eyeliner (kohl) of different price ranges (brands) available in the local market. Kohl is widely used in developing countries for babies as well adults for beautification as well eyes protection. The atomic transition lines at 405.7 nm and 425.4 nm were used as the marker lines for the detection of lead and chromium respectively. The detection system was optimized by finding the appropriate gate delay between the laser excitation and the data acquisition system and also by achieving optically thin plasma near the target by establishing the local thermodynamic equilibrium condition. The detection system was calibrated for these two hazardous elements and the kohl samples under investigation showed 8-15 ppm by mass of lead and 4-9 ppm by mass of Chromium, which are higher than the safe permissible levels of these elements. The limits of detection of the LIBS system for lead and chromium were found to be 1 and 2 ppm respectively.

  13. Validation of a commercially available indirect ELISA using a nucleocapside recombinant protein for detection of Schmallenberg virus antibodies.

    Directory of Open Access Journals (Sweden)

    Emmanuel Bréard

    Full Text Available A newly developed Enzym Like Immuno Sorbant Assay (ELISA based on the recombinant nucleocapsid protein (N of Schmallenberg virus (SBV was evaluated and validated for the detection of SBV-specific IgG antibodies in ruminant sera by three European Reference Laboratories. Validation data sets derived from sheep, goat and bovine sera collected in France and Germany (n = 1515 in 2011 and 2012 were categorized according to the results of a virus neutralization test (VNT or an indirect immuno-fluorescence assay (IFA. The specificity was evaluated with 1364 sera from sheep, goat and bovine collected in France and Belgium before 2009. Overall agreement between VNT and ELISA was 98.9% and 98.3% between VNT and IFA, indicating a very good concordance between the different techniques. Although cross-reactions with other Orthobunyavirus from the Simbu serogroup viruses might occur, it is a highly sensitive, specific and robust ELISA-test validated to detect anti-SBV antibodies. This test can be applied for SBV sero-diagnostics and disease-surveillance studies in ruminant species in Europe.

  14. Evaluation of heterogeneity dose distributions for Stereotactic Radiotherapy (SRT: comparison of commercially available Monte Carlo dose calculation with other algorithms

    Directory of Open Access Journals (Sweden)

    Takahashi Wataru

    2012-02-01

    Full Text Available Abstract Background The purpose of this study was to compare dose distributions from three different algorithms with the x-ray Voxel Monte Carlo (XVMC calculations, in actual computed tomography (CT scans for use in stereotactic radiotherapy (SRT of small lung cancers. Methods Slow CT scan of 20 patients was performed and the internal target volume (ITV was delineated on Pinnacle3. All plans were first calculated with a scatter homogeneous mode (SHM which is compatible with Clarkson algorithm using Pinnacle3 treatment planning system (TPS. The planned dose was 48 Gy in 4 fractions. In a second step, the CT images, structures and beam data were exported to other treatment planning systems (TPSs. Collapsed cone convolution (CCC from Pinnacle3, superposition (SP from XiO, and XVMC from Monaco were used for recalculating. The dose distributions and the Dose Volume Histograms (DVHs were compared with each other. Results The phantom test revealed that all algorithms could reproduce the measured data within 1% except for the SHM with inhomogeneous phantom. For the patient study, the SHM greatly overestimated the isocenter (IC doses and the minimal dose received by 95% of the PTV (PTV95 compared to XVMC. The differences in mean doses were 2.96 Gy (6.17% for IC and 5.02 Gy (11.18% for PTV95. The DVH's and dose distributions with CCC and SP were in agreement with those obtained by XVMC. The average differences in IC doses between CCC and XVMC, and SP and XVMC were -1.14% (p = 0.17, and -2.67% (p = 0.0036, respectively. Conclusions Our work clearly confirms that the actual practice of relying solely on a Clarkson algorithm may be inappropriate for SRT planning. Meanwhile, CCC and SP were close to XVMC simulations and actual dose distributions obtained in lung SRT.

  15. SU-F-T-225: Is It Time to Have Pre-Configured Therapeutic Beams Available in Commercial Treatment Planning Systems?

    International Nuclear Information System (INIS)

    Ding, G

    2016-01-01

    Purpose: Commissioning radiation beams requires considerable effort to obtain the beam data for beam configuration in a commercial treatment planning system. With the advances in technology, the manufacturer of accelerators now has the ability to adjust radiation beam parameters to meet pre-determined specifications with high precision. This study aims to illustrate the feasibility of making pre-configured radiation beams available in commercial treatment planning systems. Methods: In recent years, Varian has made a set of measured beam data from the TrueBeam accelerator available to users. Although the beam data are provided as “suggestive data” without warranty, the commissioned data measured by users have been shown to be in excellent agreement with the data set provided when the beams from the installed Linacs were adjusted to meet the beam specifications. An unofficial survey among Varian Linac TrueBeam users shows that the suggestive data set has been used with validation by users in some clinics. This indicates that radiation beams from a specified Linac can be standardized and pre-configured in a treatment planning system. Results: Two newly installed Varian TrueBeam accelerators at two different centers were examined in which one set of commissioned beam data was obtained from measurements performed by an independent physics consulting company and the other was measured by local physicists in the department. All beams from both accelerators were tuned to meet the manufacturer’s specifications. Discrepancies of less than 1% were found between the commissioned beam data from both accelerators and the suggestive data set provided by Varian. Conclusion: It may be feasible that radiation beams can be pre-configured in commercial treatment planning systems. The radiation beam users will perform the beam validation and end-to-end tests instead of configuring beams. This framework can increase both the efficiency and the accuracy in commercial radiation

  16. Antioxidant activity and polyphenol and procyanidin contents of selected commercially available cocoa-containing and chocolate products in the United States.

    Science.gov (United States)

    Miller, Kenneth B; Stuart, David A; Smith, Nancy L; Lee, Chang Y; McHale, Nancy L; Flanagan, Judith A; Ou, Boxin; Hurst, W Jeffrey

    2006-05-31

    In the United States, commercially available foods, including cocoa and chocolate, are being marketed with statements referring to the level of antioxidant activity and polyphenols. For cocoa-containing foods, there has been no comprehensive survey of the content of these and other chemistries. A survey of cocoa and chocolate-containing products marketed in the United States was conducted to determine antioxidant activity and polyphenol and procyanidin contents. Commercially available samples consisted of the top market share products in each of the following six categories: natural cocoa, unsweetened baking chocolate, dark chocolate, semisweet baking chips, milk chocolate, and chocolate syrup. Composite samples were characterized using four different methods: oxygen radical absorbance capacity (ORAC), vitamin C equivalence antioxidant capacity (VCEAC), total polyphenols, and procyanidins. All composite lots were further characterized for percent nonfat cocoa solids (NFCS) and percent fat. Natural cocoas had the highest levels of antioxidant activities, total polyphenols, and procyanidins followed by baking chocolates, dark chocolates and baking chips, and finally milk chocolate and syrups. The results showed a strong linear correlation between NFCS and ORAC (R (2) = 0.9849), total polyphenols (R (2) = 0.9793), and procyanidins (R (2) = 0.946), respectively. On the basis of principal component analysis, 81.4% of the sample set was associated with NFCS, antioxidant activity, total polyphenols, and procyanidins. The results indicated that, regardless of the product category, NFCS were the primary factor contributing to the level of cocoa antioxidants in the products tested. Results further suggested that differences in cocoa bean blends and processing, with the possible exception of Dutching, are minor factors in determining the level of antioxidants in commercially available cocoa-containing products in the United States.

  17. Novel methodology to perform sulfur hexafluoride (SF6)-based multiple-breath wash-in and washout in infants using current commercially available equipment.

    Science.gov (United States)

    Gustafsson, P M; Robinson, P D; Lindblad, A; Oberli, D

    2016-11-01

    Multiple-breath inert gas washout (MBW) is ideally suited for early detection and monitoring of serious lung disease, such as cystic fibrosis, in infants and young children. Validated commercial options for the MBW technique are limited, and suitability of nitrogen (N 2 )-based MBW is of concern given the detrimental effect of exposure to pure O 2 on infant breathing pattern. We propose novel methodology using commercially available N 2 MBW equipment to facilitate 4% sulfur hexafluoride (SF 6 ) multiple-breath inert gas wash-in and washout suitable for the infant age range. CO 2 , O 2 , and sidestream molar mass sensor signals were used to accurately calculate SF 6 concentrations. An improved dynamic method for synchronization of gas and respiratory flow was developed to take into account variations in sidestream sample flow during MBW measurement. In vitro validation of triplicate functional residual capacity (FRC) assessments was undertaken under dry ambient conditions using lung models ranging from 90 to 267 ml, with tidal volumes of 28-79 ml, and respiratory rates 20-60 per minute. The relative mean (SD, 95% confidence interval) error of triplicate FRC determinations by washout was -0.26 (1.84, -3.86 to +3.35)% and by wash-in was 0.57 (2.66, -4.66 to +5.79)%. The standard deviations [mean (SD)] of percentage error among FRC triplicates were 1.40 (1.14) and 1.38 (1.32) for washout and wash-in, respectively. The novel methodology presented achieved FRC accuracy as outlined by current MBW consensus recommendations (95% of measurements within 5% accuracy). Further clinical evaluation is required, but this new technique, using existing commercially available equipment, has exciting potential for research and clinical use. Copyright © 2016 the American Physiological Society.

  18. [Rapid screening and quality evaluation for the harmful substance 5-hydroxymethyl furfural in commercially available traditional Chinese medicine injection using LC-MS/MS method].

    Science.gov (United States)

    Zang, Qing-ce; He, Jing-jing; Bai, Jin-fa; Zheng, Ya-jie; Zhang, Rui-ping; Li, Tie-gang; Wang, Zhong-hua; He, Jiu-ming; Abliz, Zeper

    2013-11-01

    To screen the harmful substance 5-hydroxymethyl furfural content in commercially available traditional Chinese medicine injection which are commonly used, and to preliminarily evaluate the quality of these injections, 5-hydroxymethyl furfural was taken as an index. The contents of 5-hydroxymethyl furfural in 56 samples which consist of 23 kinds of traditional Chinese medicine injections and glucose injection were determined using LC-MS/MS, and 5-hydroxymethyl furfural was detected in 52 of these samples. The minimal content was 0.0038 microg x L(-1) and the maximum content was 1420 microg x mL(-1). The contents of 5-hydroxymethyl furfural were significantly different in traditional Chinese medicine injection which came from different kinds, manufacturers or batches. The results showed the quality difference of commercially available traditional Chinese medicine injection is significant taking 5-hydroxymethyl furfural content as assessment index. More attention should be paid to the safety of 5-hydroxymethyl furfural in traditional Chinese medicine injection, and unified limitation standard should be set to improve medication safety of traditional Chinese medicine injection.

  19. Validation of a commercially available enzyme-linked immunoabsorbent assay for the quantification of human α-Synuclein in cerebrospinal fluid.

    Science.gov (United States)

    Kruse, Niels; Mollenhauer, Brit

    2015-11-01

    The quantification of α-Synuclein in cerebrospinal fluid (CSF) as a biomarker has gained tremendous interest in the last years. Several commercially available immunoassays are emerging. We here describe the full validation of one commercially available ELISA assay for the quantification of α-Synuclein in human CSF (Covance alpha-Synuclein ELISA kit). The study was conducted within the BIOMARKAPD project in the European initiative Joint Program for Neurodegenerative Diseases (JPND). We investigated the effect of several pre-analytical and analytical confounders: i.e. (1) need for centrifugation of freshly drawn CSF, (2) sample stability, (3) delay of freezing, (4) volume of storage aliquots, (5) freeze/thaw cycles, (6) thawing conditions, (7) dilution linearity, (8) parallelism, (9) spike recovery, and (10) precision. None of these confounders influenced the levels of α-Synuclein in CSF significantly. We found a very high intra-assay precision. The inter-assay precision was lower than expected due to different performances of kit lots used. Overall the validated immunoassay is useful for the quantification of α-Synuclein in human CSF. Copyright © 2015 Elsevier B.V. All rights reserved.

  20. Kinematic optimization of upgrade to the Hobby-Eberly Telescope through novel use of commercially available three-dimensional CAD package

    Science.gov (United States)

    Wedeking, Gregory A.; Zierer, Joseph J.; Jackson, John R.

    2010-07-01

    The University of Texas, Center for Electromechanics (UT-CEM) is making a major upgrade to the robotic tracking system on the Hobby Eberly Telescope (HET) as part of theWide Field Upgrade (WFU). The upgrade focuses on a seven-fold increase in payload and necessitated a complete redesign of all tracker supporting structure and motion control systems, including the tracker bridge, ten drive systems, carriage frames, a hexapod, and many other subsystems. The cost and sensitivity of the scientific payload, coupled with the tracker system mass increase, necessitated major upgrades to personnel and hardware safety systems. To optimize kinematic design of the entire tracker, UT-CEM developed novel uses of constraints and drivers to interface with a commercially available CAD package (SolidWorks). For example, to optimize volume usage and minimize obscuration, the CAD software was exercised to accurately determine tracker/hexapod operational space needed to meet science requirements. To verify hexapod controller models, actuator travel requirements were graphically measured and compared to well defined equations of motion for Stewart platforms. To ensure critical hardware safety during various failure modes, UT-CEM engineers developed Visual Basic drivers to interface with the CAD software and quickly tabulate distance measurements between critical pieces of optical hardware and adjacent components for thousands of possible hexapod configurations. These advances and techniques, applicable to any challenging robotic system design, are documented and describe new ways to use commercially available software tools to more clearly define hardware requirements and help insure safe operation.

  1. Electrical and mechanical adaptation of commercially available power inverter modules for BUSSARD – The power supply of ASDEX Upgrade in vessel saddle coils

    Energy Technology Data Exchange (ETDEWEB)

    Rott, Michael, E-mail: Michael.Rott@ipp.mpg.de [Max Planck Institute for Plasma Physics, Boltzmannstrasse 2, D-85748 Garching (Germany); Arden, Nils; Eixenberger, Horst [Max Planck Institute for Plasma Physics, Boltzmannstrasse 2, D-85748 Garching (Germany); Klädtke, Kevin [Technical University Munich, Arcisstraße 21, D-80333 München (Germany); Teschke, Markus; Suttrop, Wolfgang [Max Planck Institute for Plasma Physics, Boltzmannstrasse 2, D-85748 Garching (Germany)

    2015-10-15

    Highlights: • Mechanical design of inverters for restricted space and good mountability. • Supply of DC link possible with thyristor converter. • Plant safety by independent overcurrent protections and a commercially arc detection system. • Ground fault detection by fast differential current measurement. • Possibilities of changing the inductance of a two windings iron core choke. - Abstract: To supply the ASDEX Upgrade's B-coils with AC current up to 1.3 kA{sub p} at 500 Hz with arbitrary waveforms, a set of 16 inverters has been designed and partially built. To keep cost and development time low, commercially available power modules are used and existing current converters feed the DC links. Three power modules are mounted in one cubicle for realizing a three level neutral point clamped (NPC) topology with lowest possible inductivity and making the most of the limited space available. The paper presents the effort and steps required to adapt standard power blocks towards the needs of the ASDEX Upgrade power supply as well as the mechanical optimizations for good mountability, flexibility and scalability. Besides, solutions for mandatory personnel safety and plant safety are presented.

  2. The plaque- and gingivitis-inhibiting capacity of a commercially available essential oil product. A parallel, split-mouth, single blind, randomized, placebo-controlled clinical study.

    Science.gov (United States)

    Preus, Hans Ragnar; Koldsland, Odd Carsten; Aass, Anne Merete; Sandvik, Leiv; Hansen, Bjørn Frode

    2013-11-01

    Studies have reported commercially available essential oils with convincing plaque and gingivitis preventing properties. However, no tests have compared these essential oils, i.e. Listerine(®), against their true vehicle controls. To compare the plaque and gingivitis inhibiting effect of a commercially-available essential oil (Listerine(®) Total Care) to a negative (22% hydro-alcohol solution) and a positive (0.2% chlorhexidine (CHX)) control in an experimental gingivitis model. In three groups of 15 healthy volunteers, experimental gingivitis was induced and monitored over 21 days, simultaneously treated with Listerine(®) Total Care (test), 22% hydro-alcohol solution (negative control) and 0.2% chlorhexidine solution (positive control), respectively. The upper right quadrant of each individual received mouthwash only, whereas the upper left quadrant was subject to both rinses and mechanical oral hygiene. Plaque, gingivitis and side-effects were assessed at day 7, 14 and 21. After 21 days, the chlorhexidine group showed significantly lower average plaque and gingivitis scores than the Listerine(®) and alcohol groups, whereas there was little difference between the two latter. Listerine(®) Total Care had no statistically significant effect on plaque formation as compared to its vehicle control.

  3. Electrical and mechanical adaptation of commercially available power inverter modules for BUSSARD – The power supply of ASDEX Upgrade in vessel saddle coils

    International Nuclear Information System (INIS)

    Rott, Michael; Arden, Nils; Eixenberger, Horst; Klädtke, Kevin; Teschke, Markus; Suttrop, Wolfgang

    2015-01-01

    Highlights: • Mechanical design of inverters for restricted space and good mountability. • Supply of DC link possible with thyristor converter. • Plant safety by independent overcurrent protections and a commercially arc detection system. • Ground fault detection by fast differential current measurement. • Possibilities of changing the inductance of a two windings iron core choke. - Abstract: To supply the ASDEX Upgrade's B-coils with AC current up to 1.3 kA_p at 500 Hz with arbitrary waveforms, a set of 16 inverters has been designed and partially built. To keep cost and development time low, commercially available power modules are used and existing current converters feed the DC links. Three power modules are mounted in one cubicle for realizing a three level neutral point clamped (NPC) topology with lowest possible inductivity and making the most of the limited space available. The paper presents the effort and steps required to adapt standard power blocks towards the needs of the ASDEX Upgrade power supply as well as the mechanical optimizations for good mountability, flexibility and scalability. Besides, solutions for mandatory personnel safety and plant safety are presented.

  4. To Analyse the Erosive Potential of Commercially Available Drinks on Dental Enamel and Various Tooth Coloured Restorative Materials - An In-vitro Study.

    Science.gov (United States)

    Karda, Babita; Jindal, Ritu; Mahajan, Sandeep; Sandhu, Sanam; Sharma, Sunila; Kaur, Rajwinder

    2016-05-01

    With the enormous change in life style pattern of a common man through the past few decades, there has been proportional variation in the amount and frequency of consumption of drinks. An increased consumption of these drinks will concurrently increase enamel surface roughness by demineralization, resulting in hypersensitivity and elevated caries risk. The present study was designed to evaluate the erosive potential of commercially available drinks on tooth enamel and various tooth coloured restorative materials. Extracted human teeth were taken and divided into four groups i.e. tooth enamel, glass ionomer cement, composite and compomer. Four commercially available drinks were chosen these were Coca -Cola, Nimbooz, Frooti and Yakult. The pH of each drink was measured. Each group was immersed in various experimental drinks for a period of 14 days. The erosive potential of each drink was measured by calculating the change in average surface roughness of these groups after the immersion protocol in various drinks. The data analysis was done by One Way Anova, Post-Hoc Bonferroni, and paired t -test. Group II-GIC showed highest values for mean of change in average surface roughness and the values were statistically significant (pCoca-cola showed the highest erosive potential and Yakult showed the lowest, there was no statistical significant difference between the results shown by Yakult and Frooti. Characteristics which may promote erosion of enamel and tooth coloured restorative materials were surface texture of the material and pH of the drinks.

  5. Screening Commercially Available Entomopathogenic Biocontrol Agents for the Control of Aethina tumida (Coleoptera: Nitidulidae in the UK

    Directory of Open Access Journals (Sweden)

    Giles E. Budge

    2012-08-01

    Full Text Available The Small hive beetle, Aethina tumida, is an invasive pest of honey bees. Indigenous to sub-Saharan Africa, it has now become established in North America and Australia. It represents a serious threat to European honey bees. Commercially available entomopathogenic agents were screened for their potential to control beetle larvae. Entomopathogenic fungi investigated had minimal impact. The nematodes Steinernema kraussei and S. carpocapsae provided excellent control with 100% mortality of larvae being obtained. Sequential applications of the nematodes following larvae entering sand to pupate also provided excellent control for up to 3 weeks. The information gained supports the development of contingency plans to deal with A. tumida should it occur in the UK, and is relevant to the management of Small hive beetle where it is already present.

  6. An Assessment of Myotube Morphology, Matrix Deformation, and Myogenic mRNA Expression in Custom-Built and Commercially Available Engineered Muscle Chamber Configurations

    Directory of Open Access Journals (Sweden)

    Julia M. Jones

    2018-05-01

    Full Text Available There are several three-dimensional (3D skeletal muscle (SkM tissue engineered models reported in the literature. 3D SkM tissue engineering (TE aims to recapitulate the structure and function of native (in vivo tissue, within an in vitro environment. This requires the differentiation of myoblasts into aligned multinucleated myotubes surrounded by a biologically representative extracellular matrix (ECM. In the present work, a new commercially available 3D SkM TE culture chamber manufactured from polyether ether ketone (PEEK that facilitates suitable development of these myotubes is presented. To assess the outcomes of the myotubes within these constructs, morphological, gene expression, and ECM remodeling parameters were compared against a previously published custom-built model. No significant differences were observed in the morphological and gene expression measures between the newly introduced and the established construct configuration, suggesting biological reproducibility irrespective of manufacturing process. However, TE SkM fabricated using the commercially available PEEK chambers displayed reduced variability in both construct attachment and matrix deformation, likely due to increased reproducibility within the manufacturing process. The mechanical differences between systems may also have contributed to such differences, however, investigation of these variables was beyond the scope of the investigation. Though more expensive than the custom-built models, these PEEK chambers are also suitable for multiple use after autoclaving. As such this would support its use over the previously published handmade culture chamber system, particularly when seeking to develop higher-throughput systems or when experimental cost is not a factor.

  7. A comparative evaluation of accuracy of Mclaughlin Bennet Trevisi prescription of six commercially available orthodontic metal brackets: An in vitro study

    Directory of Open Access Journals (Sweden)

    Prateek Navratan Daga

    2017-01-01

    Full Text Available Introduction: While using preadjusted edgewise mechanics, tooth positioning relies on the accuracy of bracket prescription for correct expression of tip and torque when using full-size archwire, thus making accuracy of bracket prescription vital in its overall performance. This study aimed to investigate the precision offered in bracket prescription: slot dimensions, tip, and torque values. Materials and Methods: MBT prescriptions of upper left central incisor brackets manufactured by six different commercial houses were evaluated to assess the aforementioned accuracy of bracket slot dimensions as well as tip and torque values. Rapid-I Precision Measuring System was used to accurately determine slot dimensions as well as tip and torque values. Results: Results obtained in a descending order of accuracy were as follows: American Orthodontics, Ortho Organizers, 3M Unitek, Forestadent, Modern Orthodontics and JJ Orthodontics. The obtained results were evaluated statistically using one-way ANOVA test. P< 0.05 was considered statistically significant. Conclusion: This study helps us to note the accuracy level of the inherent prescription values offered in various commercial houses and the likely effect the same may have on our expectation of a prescription finish while using attachments from any of them.

  8. Computational Fluid Dynamics (CFD Analysis of Phthalic Anhydride’s Yield Using Lab Synthesized and Commercially Available (V2O5/TiO2 Catalyst

    Directory of Open Access Journals (Sweden)

    A. Sarosh

    2018-04-01

    Full Text Available V2O5/TiO2 is an important catalyst used in many industrial reactions like selective oxidation of o-xylene to phthalic anhydride, selective catalytic reduction of NOx, selective oxidation of alkanes, etc. The partial oxidation of o-xylene to synthesize phthalic anhydride is an exothermic reaction and leaves hot spots on the catalyst’s surface. The yield of phthalic anhydride strongly depends on the activity and stability of the catalyst. In this work, a computational fluid dynamics (CFD analysis has been conducted to compare the yield of lab prepared catalyst with the commercially used catalyst. This work is first attempt to simulate V2O5/TiO2 catalyst for cracking heavy hydrocarbons in the petrochemical industry using k- ε turbulence and species transport models in CFD. The results obtained are in the form of scaled residuals, area-weighted average, and contours of pressure and temperature. Simulation results of lab synthesized and commercially used catalysts, applying finite volume method (FVM are compared, which emphasize the scope of CFD modeling in the catalytic cracking process of petrochemical industry.

  9. A method for evaluating image quality of monochrome and color displays based on luminance by use of a commercially available color digital camera

    Energy Technology Data Exchange (ETDEWEB)

    Tokurei, Shogo, E-mail: shogo.tokurei@gmail.com, E-mail: junjim@med.kyushu-u.ac.jp [Department of Health Sciences, Graduate School of Medical Sciences, Kyushu University, 3-1-1 Maidashi, Higashi-ku, Fukuoka, Fukuoka 812-8582, Japan and Department of Radiology, Yamaguchi University Hospital, 1-1-1 Minamikogushi, Ube, Yamaguchi 755-8505 (Japan); Morishita, Junji, E-mail: shogo.tokurei@gmail.com, E-mail: junjim@med.kyushu-u.ac.jp [Department of Health Sciences, Faculty of Medical Sciences, Kyushu University, 3-1-1 Maidashi, Higashi-ku, Fukuoka, Fukuoka 812-8582 (Japan)

    2015-08-15

    Purpose: The aim of this study is to propose a method for the quantitative evaluation of image quality of both monochrome and color liquid-crystal displays (LCDs) using a commercially available color digital camera. Methods: The intensities of the unprocessed red (R), green (G), and blue (B) signals of a camera vary depending on the spectral sensitivity of the image sensor used in the camera. For consistent evaluation of image quality for both monochrome and color LCDs, the unprocessed RGB signals of the camera were converted into gray scale signals that corresponded to the luminance of the LCD. Gray scale signals for the monochrome LCD were evaluated by using only the green channel signals of the camera. For the color LCD, the RGB signals of the camera were converted into gray scale signals by employing weighting factors (WFs) for each RGB channel. A line image displayed on the color LCD was simulated on the monochrome LCD by using a software application for subpixel driving in order to verify the WF-based conversion method. Furthermore, the results obtained by different types of commercially available color cameras and a photometric camera were compared to examine the consistency of the authors’ method. Finally, image quality for both the monochrome and color LCDs was assessed by measuring modulation transfer functions (MTFs) and Wiener spectra (WS). Results: The authors’ results demonstrated that the proposed method for calibrating the spectral sensitivity of the camera resulted in a consistent and reliable evaluation of the luminance of monochrome and color LCDs. The MTFs and WS showed different characteristics for the two LCD types owing to difference in the subpixel structure. The MTF in the vertical direction of the color LCD was superior to that of the monochrome LCD, although the WS in the vertical direction of the color LCD was inferior to that of the monochrome LCD as a result of luminance fluctuations in RGB subpixels. Conclusions: The authors

  10. Evaluation of five commercially available assays and measurement of serum total protein concentration via refractometry for the diagnosis of failure of passive transfer of immunity in foals.

    Science.gov (United States)

    Davis, Rachel; Giguère, Steeve

    2005-11-15

    To determine and compare sensitivity, specificity, accuracy, and predictive values of measurement of serum total protein concentration by refractometry as well as 5 commercially available kits for the diagnosis of failure of passive transfer (FPT) of immunity in foals. Prospective study. 65 foals with various medical problems and 35 clinically normal foals. IgG concentration in serum was assessed by use of zinc sulfate turbidity (assay C), glutaraldehyde coagulation (assay D), 2 semiquantitative immunoassays (assays F and G), and a quantitative immunoassay (assay H). Serum total protein concentration was assessed by refractometry. Radial immunodiffusion (assays A and B) was used as the reference method. For detection of IgG or = 6.0 g/dL indicated adequate IgG concentrations. Most assays were adequate as initial screening tests. However, their use as a definitive test would result in unnecessary treatment of foals with adequate IgG concentrations.

  11. Towards 15% energy conversion efficiency: a systematic study of the solution-processed organic tandem solar cells based on commercially available materials

    DEFF Research Database (Denmark)

    Li, Ning; Baran, Derya; Forberich, Karen

    2013-01-01

    in organic tandem solar cells. All the devices are processed under environmental conditions using doctor-blading, which is highly compatible with mass-production coating technologies. Power conversion efficiencies (PCE) of 6–7% are obtained for OPV devices based on different active layers. Optical...... simulations based on experimental data are performed for all realized tandem solar cells. An efficiency potential of ∼10% is estimated for these compounds in combination with phenyl-C61-butyric acid methyl ester (PCBM) as an acceptor. In addition, we assume a hypothetical, optimized acceptor to understand...... the limitation of donors. It is suggested that a PCE of >14% is realistic for tandem solar cells based on these commercially available donor materials. Along with the demonstration of novel intermediate layers we believe that this systematic study provides valuable insight for those attempting to realize...

  12. Synthesis of enantiomerically enriched drug precursors and an insect pheromone via reduction of ketones using commercially available carbonyl reductase screening kit "Chiralscreen® OH".

    Science.gov (United States)

    Nagai, Toshiya; Sakurai, Saki; Natori, Naoki; Hataoka, Manaka; Kinoshita, Takako; Inoue, Hiroyoshi; Hanaya, Kengo; Shoji, Mitsuru; Sugai, Takeshi

    2018-04-01

    Commercially available "Chiralscreen® OH" starter kit containing five types of carbonyl reductases (E001, E007, E031, E039, and E078) was used for the reduction of several aromatic and aliphatic ketones to obtain enantiomerically enriched drug precursors and an insect pheromone. Almost stereochemically pure secondary alcohols, used in the synthesis of drugs such as (R)-rasagiline mesylate, (S)-rivastigmine, (R)-chlorphenesin carbamate, and (R)-mexiletine, and the insect pheromone (4S,5R)-sitophilure, were conveniently obtained. The enzymes worked well with ketones containing at least one non-bulky substituent at the carbonyl group. The diverse stereochemical preference of the above five carbonyl reductases was clarified. Copyright © 2017 Elsevier Ltd. All rights reserved.

  13. Bituminization of simulated PWR type reactor wastes, boric evaporator bottons and ion exchange resins, carried out in CNEN/SP using commercial bitumen available in the Brazilian market

    International Nuclear Information System (INIS)

    Grosche Filho, C.E.; Chandra, U.

    1986-01-01

    The first results of the study of bituminization of simulated PWR wastes, boric evaporator bottons and spent ion-exclange resins (OH - , H + ) and incinerated ash-wates are presented and discussed. The study consisted of characterization of the commercial bitumen, locally available and bitumen wastes products of varying whight compositions. The characterization was carried out using standard analysis methods of ABNT and ASTM, and included measurement of, penetration, softening point and flash point. In addition, the bitumen samples were analized for their resin and asphaltene contents. For leaching studies, wastes products of bitumen and resin loaded with 134 Cs were utilized. The method used was according to the ISO norms. The simulation of the industrial process was carried out using an extruder-evaporator typically used in the plastic industries offered by Industria de Maquinas Miotto Ltda., Sao Bernardo do Campo - SP. (Author) [pt

  14. A phantom-based evaluation of three commercially available patient organ shields for computed tomography X-ray examinations in diagnostic radiology

    International Nuclear Information System (INIS)

    Huggett, J.; Mukonoweshuro, W.; Loader, R.

    2013-01-01

    Three commercially available in-plane patient organ shields (barium eye, bismuth eye and bismuth breast) for computed tomography (CT) examinations were evaluated to determine their effectiveness for dose reduction. Absorbed doses were measured using metal oxide semiconductor field effect transistor dosemeters fastened to a Kyoto CT Torso phantom. Resultant images were visually compared with those minus shielding by an experienced radiologist. Approximate dose reductions of 21, 38 and 50 % were achieved by the barium eye, bismuth eye and bismuth breast shields, respectively, at a cost of increased image noise and streak artefacts. Shielded images produced varied levels of image artefact, particularly those resulting from the eye shields. Measured dose reductions were not consistent with the potential dose savings stated by the manufacturers of the shields. When evaluating the breast shield, similar dose reduction was achieved without shield-induced artefact by simply reducing the X-ray tube current. (authors)

  15. Effect of three commercially available chewing gums on salivary flow rate and pH in caries-active and caries-free children: An in vivo study.

    Science.gov (United States)

    Vantipalli, Usha Kiran; Avula, Sai Sankar Jogendra; Enuganti, Sridevi; Bandi, Sujatha; Kakarla, Pranitha; Kuravadi, Raja Vardhan

    2017-01-01

    Adequate salivary flow is an important requisite in the maintenance of oral health. Salivary flow increases in response to both gustatory (taste) and mechanical (chewing) stimuli. Hence, the aim of the present study was to know the efficacy of commercially available chewing gums (sugar free and sugared) on salivary flow rate (SFR) and pH in caries-active and caries-free children. One hundred school children aged between 10 and 12 years were divided into two groups on the basis of their caries status into caries free and caries active. Unstimulated saliva was collected before start of the study. Both groups were subjected to three commercially available chewing gums (2 sugar free, 1 sugared) on consecutive days, and saliva was collected at intervals of 2 min (T2), 10 min (T10), and 30 min (T30). The pH and flow rate of saliva samples were measured before and specified time intervals after gum chewing. In both the groups, gum chewing increased the SFR, significantly at T2, and gradually declined at T30 which was significantly higher than baseline values. The pH raised significantly at T2 and gradually declined at T30 which was significantly higher than baseline values with sugar-free gums, but with sugared gums, the pH raised slightly at T2 and dropped significantly at T30. However, no statistically significant differences in pH and flow rate were noticed in both the groups. Chewing of sugar-free gums in both caries-active and caries-free children may aid in reducing the incidence of dental caries.

  16. Performance and diagnostic usefulness of commercially available enzyme linked immunosorbent assay and rapid kits for detection of HIV, HBV and HCV in India.

    Science.gov (United States)

    Maity, Susmita; Nandi, Srijita; Biswas, Subrata; Sadhukhan, Salil Kumar; Saha, Malay Kumar

    2012-11-26

    HIV, HBV and HCV pose a major public health problem throughout the world. Detection of infection markers for these agents is a major challenge for testing laboratories in a resource poor setting. As blood transfusion is an important activity saving millions of live every year, it also carries a risk of transfusion transmissible infections caused by these fatal blood borne pathogens if the quality of testing is compromised. Conventional ELISA is regarded as the mostly used screening technique but due to limitations like high cost, unavailability in many blood banks and testing sites, involvement of costly instruments, time taking nature and requirement of highly skilled personnel for interpretation, rapid tests are gaining more importance and warrants comparison of performance. A comparative study between these two techniques has been performed using commercially available diagnostic kits to assess their efficacy for detection of HIV, HBV and HCV infections. Rapid kits were more efficient in specificity with synthetic antigens along with high PPV than ELISA in most cases. Comparison between different ELISA kits revealed that Microlisa HIV and Hepalisa (J. Mitra & Co. Pvt. Ltd.); ERBA LISA HIV1 + 2, ERBA LISA Hepatitis B and ERBA LISA HCV (Transasia Bio-medicals Ltd.) gives uniform result with good performance in terms of sensitivity, specificity, PPV, NPV and efficiency, whereas, Microlisa HCV (J. Mitra & Co. Pvt. Ltd.), Microscreen HBsAg ELISA and INNOVA HCV (Span Diagnostics Ltd.) did not perform well. Rapid kits were also having high degree of sensitivity and specificity (100%) except in HIV Comb and HCV Comb (J. Mitra & Co. Pvt. Ltd.). The kit efficiency didn't vary significantly among different companies and lots in all the cases except for HCV ELISA showing statistically significant variation (p bank. For availability of quality commercial diagnostic assays, evaluation of kit may be helpful.

  17. Efficacy of a pandemic (H1N1) 2009 virus vaccine in pigs against the pandemic influenza virus is superior to commercially available swine influenza vaccines.

    Science.gov (United States)

    Loeffen, W L A; Stockhofe, N; Weesendorp, E; van Zoelen-Bos, D; Heutink, R; Quak, S; Goovaerts, D; Heldens, J G M; Maas, R; Moormann, R J; Koch, G

    2011-09-28

    In April 2009 a new influenza A/H1N1 strain, currently named "pandemic (H1N1) influenza 2009" (H1N1v), started the first official pandemic in humans since 1968. Several incursions of this virus in pig herds have also been reported from all over the world. Vaccination of pigs may be an option to reduce exposure of human contacts with infected pigs, thereby preventing cross-species transfer, but also to protect pigs themselves, should this virus cause damage in the pig population. Three swine influenza vaccines, two of them commercially available and one experimental, were therefore tested and compared for their efficacy against an H1N1v challenge. One of the commercial vaccines is based on an American classical H1N1 influenza strain, the other is based on a European avian H1N1 influenza strain. The experimental vaccine is based on reassortant virus NYMC X179A (containing the hemagglutinin (HA) and neuraminidase (NA) genes of A/California/7/2009 (H1N1v) and the internal genes of A/Puerto Rico/8/34 (H1N1)). Excretion of infectious virus was reduced by 0.5-3 log(10) by the commercial vaccines, depending on vaccine and sample type. Both vaccines were able to reduce virus replication especially in the lower respiratory tract, with less pathological lesions in vaccinated and subsequently challenged pigs than in unvaccinated controls. In pigs vaccinated with the experimental vaccine, excretion levels of infectious virus in nasal and oropharyngeal swabs, were at or below 1 log(10)TCID(50) per swab and lasted for only 1 or 2 days. An inactivated vaccine containing the HA and NA of an H1N1v is able to protect pigs from an infection with H1N1v, whereas swine influenza vaccines that are currently available are of limited efficaciousness. Whether vaccination of pigs against H1N1v will become opportune remains to be seen and will depend on future evolution of this strain in the pig population. Close monitoring of the pig population, focussing on presence and evolution of

  18. Robotic surgery training with commercially available simulation systems in 2011: a current review and practice pattern survey from the society of urologic robotic surgeons.

    Science.gov (United States)

    Lallas, Costas D; Davis, John W

    2012-03-01

    Virtual reality (VR) simulation has the potential to standardize surgical training for robotic surgery. We sought to evaluate all commercially available VR robotic simulators. A MEDLINE(®) literature search was performed of all applicable keywords. Available VR simulators were evaluated with regard to face, content, and construct validation. Additionally, a survey was e-mailed to all members of the Endourological Society, querying the pervasiveness of VR simulators in robotic surgical training. Finally, each company was e-mailed to ask for a price quote for their respective system. There are four VR robotic surgical simulators currently available: RoSS™, dV-Trainer™, SEP Robot™, and da Vinci(®) Skills Simulator™. Each system is represented in the literature and all possess varying degrees of face, content, and construct validity. Although all systems have basic skill sets with performance analysis and metrics software, most do not contain procedural components. When evaluating the results of our survey, most respondents did not possess a VR simulator although almost all believed there to be great potential for these devices in robotic surgical training. With the exception of the SEP Robot, all VR simulators are similar in price. VR simulators have a definite role in the future of robotic surgical training. Although the simulators target technical components of training, their largest impact will be appreciated when incorporated into a comprehensive educational curriculum.

  19. Open Access Articles Have a Greater Research Impact Than Articles Not Freely Available, A review of: Antelman, Kristin. “Do Open-Access Articles Have a Greater Research Impact?” College & Research Libraries 65.5 (Sep. 2004: 372-82.

    Directory of Open Access Journals (Sweden)

    Suzanne P. Lewis

    2006-09-01

    Full Text Available Objective – To ascertain whether open access articles have a greater research impact than articles not freely available, as measured by citations in the ISI Web of Science database. Design – Analysis of mean citation rates of a sample population of journal articles across four disciplines. Setting – Journal literature across the disciplines of philosophy, political science, mathematics, and electrical and electronic engineering. Subjects – A sample of 2,017 articles across the four disciplines published between 2001 and 2002 (for political science, mathematics, and electrical and electronic engineering and between 1999 and 2000 (for philosophy. Methods – A systematic presample of articles for each of the disciplines was taken to calculate the necessary sample sizes. Based on this calculation, articles were sourced from ten leading journals in each discipline. The leading journals in political science, mathematics, and electrical and electronic engineering were defined by ISI’s Journal Citation Reports for 2002. The ten leading philosophy journals were selected using a combination of other methods. Once the sample population had been identified, each article title and the number of citations to each article (in the ISI Web of Science database were recorded. Then the article title was searched in Google and if any freely available full text version was found, the article was classified as open access. The mean citation rate for open access and non‐open access articles in each discipline was identified, and the percentage difference between the means was calculated. Main results – The four disciplines represented a range of open access uptake: 17% of articles in philosophy were open access, 29% in political science, 37% in electrical and electronic engineering, and 69% in mathematics. There was a significant difference in the mean citation rates for open access articles and non‐open access articles in all four disciplines. The

  20. Performance and diagnostic usefulness of commercially available enzyme linked immunosorbent assay and rapid kits for detection of HIV, HBV and HCV in India

    Directory of Open Access Journals (Sweden)

    Maity Susmita

    2012-11-01

    Full Text Available Abstract Background HIV, HBV and HCV pose a major public health problem throughout the world. Detection of infection markers for these agents is a major challenge for testing laboratories in a resource poor setting. As blood transfusion is an important activity saving millions of live every year, it also carries a risk of transfusion transmissible infections caused by these fatal blood borne pathogens if the quality of testing is compromised. Conventional ELISA is regarded as the mostly used screening technique but due to limitations like high cost, unavailability in many blood banks and testing sites, involvement of costly instruments, time taking nature and requirement of highly skilled personnel for interpretation, rapid tests are gaining more importance and warrants comparison of performance. Results A comparative study between these two techniques has been performed using commercially available diagnostic kits to assess their efficacy for detection of HIV, HBV and HCV infections. Rapid kits were more efficient in specificity with synthetic antigens along with high PPV than ELISA in most cases. Comparison between different ELISA kits revealed that Microlisa HIV and Hepalisa (J. Mitra & Co. Pvt. Ltd.; ERBA LISA HIV1 + 2, ERBA LISA Hepatitis B and ERBA LISA HCV (Transasia Bio-medicals Ltd. gives uniform result with good performance in terms of sensitivity, specificity, PPV, NPV and efficiency, whereas, Microlisa HCV (J. Mitra & Co. Pvt. Ltd., Microscreen HBsAg ELISA and INNOVA HCV (Span Diagnostics Ltd. did not perform well. Rapid kits were also having high degree of sensitivity and specificity (100% except in HIV Comb and HCV Comb (J. Mitra & Co. Pvt. Ltd.. The kit efficiency didn’t vary significantly among different companies and lots in all the cases except for HCV ELISA showing statistically significant variation (p  Conclusions ELISA is a good screening assay for markers of HIV, HBV and HCV infections. Rapid tests are useful for

  1. Computational tools and resources for metabolism-related property predictions. 1. Overview of publicly available (free and commercial) databases and software.

    Science.gov (United States)

    Peach, Megan L; Zakharov, Alexey V; Liu, Ruifeng; Pugliese, Angelo; Tawa, Gregory; Wallqvist, Anders; Nicklaus, Marc C

    2012-10-01

    Metabolism has been identified as a defining factor in drug development success or failure because of its impact on many aspects of drug pharmacology, including bioavailability, half-life and toxicity. In this article, we provide an outline and descriptions of the resources for metabolism-related property predictions that are currently either freely or commercially available to the public. These resources include databases with data on, and software for prediction of, several end points: metabolite formation, sites of metabolic transformation, binding to metabolizing enzymes and metabolic stability. We attempt to place each tool in historical context and describe, wherever possible, the data it was based on. For predictions of interactions with metabolizing enzymes, we show a typical set of results for a small test set of compounds. Our aim is to give a clear overview of the areas and aspects of metabolism prediction in which the currently available resources are useful and accurate, and the areas in which they are inadequate or missing entirely.

  2. Evaluation of efficacy of a commercially available herbal mouthwash on dental plaque and gingivitis: A double-blinded parallel randomized controlled trial

    Directory of Open Access Journals (Sweden)

    Sanjukta Bagchi

    2015-01-01

    Full Text Available Aim: To evaluate if a commercially available herbal mouthwash, can be a better choice as an anti-plaque and antigingivitis agent when compared with chlorhexidine. Materials and Methods: In a double-blind, parallel group randomized clinical trial 90 nursing students aged 18-25 years were randomly divided into three groups: A (chlorhexidine, B (HiOra and C (distilled water. These groups were asked to rinse with their respective mouthwash two times daily for 21 days. Plaque and gingivitis were evaluated by using Turesky et al. modification of Quigley Hein Plaque Index (1970 and Modified Gingival Index by Lobene et al. (1986 respectively. Statistical analysis was done using ANOVA test. Results: There was statistically significant reduction in plaque and gingival scores from baseline to 21 days in both the groups A and B. Conclusions: Although chlorhexidine group proved to be the best anti-plaque and antigingivitis agent, it was found that HiOra group also showed gradual improvement from baseline to 21 days. Whereas no improvement was seen in the Group C using distilled water over 21 days.

  3. Assessing Greater Sage-Grouse Selection of Brood-Rearing Habitat Using Remotely-Sensed Imagery: Can Readily Available High-Resolution Imagery Be Used to Identify Brood-Rearing Habitat Across a Broad Landscape?

    Science.gov (United States)

    Westover, Matthew; Baxter, Jared; Baxter, Rick; Day, Casey; Jensen, Ryan; Petersen, Steve; Larsen, Randy

    2016-01-01

    Greater sage-grouse populations have decreased steadily since European settlement in western North America. Reduced availability of brood-rearing habitat has been identified as a limiting factor for many populations. We used radio-telemetry to acquire locations of sage-grouse broods from 1998 to 2012 in Strawberry Valley, Utah. Using these locations and remotely-sensed NAIP (National Agricultural Imagery Program) imagery, we 1) determined which characteristics of brood-rearing habitat could be used in widely available, high resolution imagery 2) assessed the spatial extent at which sage-grouse selected brood-rearing habitat, and 3) created a predictive habitat model to identify areas of preferred brood-rearing habitat. We used AIC model selection to evaluate support for a list of variables derived from remotely-sensed imagery. We examined the relationship of these explanatory variables at three spatial extents (45, 200, and 795 meter radii). Our top model included 10 variables (percent shrub, percent grass, percent tree, percent paved road, percent riparian, meters of sage/tree edge, meters of riparian/tree edge, distance to tree, distance to transmission lines, and distance to permanent structures). Variables from each spatial extent were represented in our top model with the majority being associated with the larger (795 meter) spatial extent. When applied to our study area, our top model predicted 75% of naïve brood locations suggesting reasonable success using this method and widely available NAIP imagery. We encourage application of our methodology to other sage-grouse populations and species of conservation concern.

  4. Two-Spotted Ladybeetle Adalia bipunctata L. (Coleoptera: Coccinellidae): A Commercially Available Predator to Control Asian Citrus Psyllid Diaphorina citri (Hemiptera: Liviidae).

    Science.gov (United States)

    Khan, Azhar A; Qureshi, Jawwad A; Afzal, Muhammad; Stansly, Philip A

    2016-01-01

    The Asian citrus psyllid Diaphorina citri Kuwayama (Hemiptera: Liviidae) is an economically important pest of citrus because it serves as a vector of the causal pathogens of huanglongbing (HLB) also known as citrus greening disease. The increased use of insecticides for control of D. citri negatively impacts several natural enemies including some effective ladybeetle species which are not available commercially. The two-spotted ladybeetle, Adalia bipunctata (Coleoptera: Coccinellidae) is found in some crop and forest ecosystems of Asia, Europe and North America and available commercially. It is known to attack aphids and mealybugs but there are no published records of feeding on psyllids. We evaluated suitability and preference of A. bipunctata for nymphs of D. citri compared to corn leaf aphid Rhopalosiphum maidis (Hemiptera: Aphididae) a global pest of cereal crops and prey for many predaceous insects. We also compared development and reproduction of A. bipunctata on these two species with frozen eggs of the Mediterranean flour moth Ephestia kuehniella (Lepidoptera: Pyralidae) at 25°C. Initially, more D. citri than R. maidis nymphs were consumed in the no-choice tests although final consumption by larva and adult of A. bipunctata did not differ in the choice and no-choice tests. Larval development was prolonged by one day on D. citri compared to R. maidis nymphs but did not differ between either of these diets and E. kuehniella. Larval survival to adult averaged 93-100% and was not impacted by diet. Adult life span did not differ between diets although those on D. citri and R. maidis nymphs weighed less and produced fewer but more fertile eggs than on E. kuehniella eggs. Significant reduction of D. citri nymphs averaging 54% was observed in colonies caged with adult A. bipunctata on field planted citrus. R° (net reproductive rate) was least for beetles fed R. maidis, but otherwise there were no significant differences in demographic parameters. Successful

  5. Implementation of an Enzyme Linked Immunosorbent Assay for the Quantification of Allergenic Egg Residues in Red Wines Using Commercially Available Antibodies

    Science.gov (United States)

    Koestel, Carole; Simonin, Céline; Belcher, Sandrine

    2016-01-01

    Abstract Since the early 2000s, labeling of potentially allergenic food components to protect people who suffer from food allergies is compulsory in numerous industrialized countries. In Europe, milk and egg components used during the winemaking process must be indicated on the label since July 1, 2012. Several ELISA procedures have been developed to detect allergenic residues in wines. However, the complexity of the wine matrix can inhibit the immunoenzymatic reaction. The aim of this study was to implement an ELISA assay for the detection of ovalbumin in red wines using commercially available antibodies. The specificity of the acquired antibodies and the absence of cross reactivity were assessed by immunoblotting and ELISA. An ELISA assay with a LOD of 14.2 μg/L and a LOQ of 56.4 μg/L of ovalbumin in aqueous solution was obtained. Differences in ELISA signals were observed when analyzing various fining agents, although reproducible conformation of the antigen could be reached for the comparison of ovalbumin and Ovicolle. The differences between samples in terms of pH could be leveled but the inhibition of the ELISA signal, positively correlated to the tannin content of the wines, could not be suppressed. Thus, standard curves of ovalbumin in several wines were obtained by relative quantification. The control steps and the difficulties encountered presented in this study should be considered by anybody working toward the development of ELISA assays for the detection of allergenic residues in complex food matrices. PMID:27356183

  6. Evaluation of a commercially available molybdate formulation and zinc oxide boluses in preventing hepatic copper accumulation and thus enzootic icterus in sheep

    Directory of Open Access Journals (Sweden)

    C.J. Botha

    2001-07-01

    Full Text Available The efficacy of a molybdate formulation and a zinc oxide bolus as prophylactic agents for enzootic icterus was evaluated in sheep. Before copper loading, liver biopsies were performed on 12 male, 6-month-old, Mutton Merino sheep to determine hepatic copper (Cu and zinc (Zn concentrations. The animals were restrictively randomised according to liver copper concentrations to 3 treatment groups (n = 4 to achieve similar mean liver copper concentrations per group. All sheep received 4 m /kg of a 0.5 %aqueous solution of CuSO4·5H2O intraruminally 7 days per week for 10 weeks. On Day 0 the sheep in the Mo-group were injected subcutaneously with 42 mg molybdenum (Mo contained in a commercial molybdate formulation. The animals in the Zn-group each received a zinc oxide bolus, containing 43 g zinc oxide, via a rumen cannula. Treatment was repeated on Day 42. Four animals served as untreated controls. Urinary copper excretion, plasma copper concentration, haematocrit and glutamate dehydrogenase (GLDH activity were determined throughout the trial. The animals were sacrificed after 10 weeks and liver samples were submitted for histopathological examination. Liver and kidney copper and zinc concentrations were determined. Neither the molybdate treatment nor the zinc oxide boluses prevented hepatic copper accumulation. The urinary copper excretion, plasma copper concentration, haematocrit and GLDH activity were not significantly different (P > 0.05 from the controls.

  7. Alveolar wound healing after implantation with a pool of commercially available bovine bone morphogenetic proteins (BMPs): a histometric study in rats.

    Science.gov (United States)

    Calixto, Romeu Felipe Elias; Teófilo, Juliana Mazzonetto; Brentegani, Luiz Guilherme; Lamano-Carvalho, Teresa Lúcia

    2007-01-01

    The capacity of a commercially available pool of bovine bone morphogenetic proteins (BMPs) to stimulate osteogenesis in the rat alveolar healing was investigated by histometric analysis. Male rats were anesthetized and had their upper incisor extracted. A pool of purified bovine BMPs adsorbed to microgranular resorbable hydroxyapatite was agglutinated with bovine collagen and saline before implantation into the alveolar socket. The implanted and control rats (n=30 per group) were sacrificed 1 to 9 weeks postoperatively, the hemi-maxillae were decalcified, processed for paraffin embedding and semi-serial longitudinal sections were obtained and stained with hematoxylin and eosin. The volume fraction of alveolar healing components was estimated by a differential point-counting method in histologic images. The results showed that in both, control and implanted rats, the alveolar healing followed the histologic pattern usually described in the literature. Quantitative data confirmed that the BMPs mixture did not stimulate new bone formation in the alveolar socket of implanted rats. These results suggest that the pool of BMPs adsorbed to hydroxyapatite and agglutinated with bovine collagen did not warrant incorporation of the osteoinductive proteins to a slow-absorption system that would allow a BMPs release rate compatible to that of new bone formation, and thus more adequate to osteoinduction.

  8. Field evaluation of a new commercially available ELISA based on a recombinant antigen for diagnosing Chlamydophila abortus (Chlamydia psittaci serotype 1) infection.

    Science.gov (United States)

    Buendía, A J; Cuello, F; Del Rio, L; Gallego, M C; Caro, M R; Salinas, J

    2001-02-12

    A new commercially available ELISA (ELISAr-Chlamydia) for detecting antibodies against Chlamydophila abortus has been evaluated using sheep field serum samples. The ELISA is based on a recombinant antigen which expresses part of a protein from the 80-90kDa family that is specific to C. abortus. Sera (105) from six flocks with confirmed ovine chlamydial abortion (OEA) outbreaks were used in this study, as well as sera (258) from 18 flocks which had suffered no OEA in the last lambing. The ELISAr-Chlamydia was compared with the complement fixation test (CFT) and with an ELISA using purified C. abortus elementary bodies (ELISA-EB), employing as reference technique a comparative microimmunofluorescence test that differentiates C. abortus infection from Chlamydophila pecorum infection. The results showed that the sensitivity of ELISAr-Chlamydia was 90.9% with a specificity of 85.9%, the sensitivity of CFT was 71.0% with a specificity of 83.6%, while the sensitivity of ELISA-EB was 95.2% and the specificity was 54.2%. Furthermore, ELISAr-Chlamydia was the test with fewer false positives resulting from positive reactivity to C. pecorum, although 15% of the sera positive for C. pecorum but negative for C. abortus antibodies reacted positively. This study demonstrated with field material that ELISAr-Chlamydia provides the most balanced results between sensitivity and specificity, especially in flocks with no clinical OEA but reactivity to C. abortus.

  9. Comparison of ultraviolet A light protection standards in the United States and European Union through in vitro measurements of commercially available sunscreens.

    Science.gov (United States)

    Wang, Steven Q; Xu, Haoming; Stanfield, Joseph W; Osterwalder, Uli; Herzog, Bernd

    2017-07-01

    The importance of adequate ultraviolet A light (UVA) protection has become apparent in recent years. The United States and Europe have different standards for assessing UVA protection in sunscreen products. We sought to measure the in vitro critical wavelength (CW) and UVA protection factor (PF) of commercially available US sunscreen products and see if they meet standards set by the United States and the European Union. Twenty sunscreen products with sun protection factors ranging from 15 to 100+ were analyzed. Two in vitro UVA protection tests were conducted in accordance with the 2011 US Food and Drug Administration final rule and the 2012 International Organization for Standardization method for sunscreen effectiveness testing. The CW of the tested sunscreens ranged from 367 to 382 nm, and the UVA PF of the products ranged from 6.1 to 32. Nineteen of 20 sunscreens (95%) met the US requirement of CW >370 nm. Eleven of 20 sunscreens (55%) met the EU desired ratio of UVA PF/SPF > 1:3. The study only evaluated a small number of sunscreen products. The majority of tested sunscreens offered adequate UVA protection according to US Food and Drug Administration guidelines for broad-spectrum status, but almost half of the sunscreens tested did not pass standards set in the European Union. Copyright © 2017. Published by Elsevier Inc.

  10. Performance of the commercially available SERION ELISA classic Echinococcus IgG test for the detection of cystic echinococcosis in clinical practice.

    Science.gov (United States)

    Sarink, M J; Koelewijn, R; Slingerland, B C G C; Tielens, A G M; van Genderen, P J J; van Hellemond, J J

    2018-06-28

    Diagnosis of cystic echinococcosis (CE) is at present mainly based on imaging techniques. Serology has a complementary role, partly due to the small number of standardized and commercially available assays. Therefore we examined the clinical performance of the SERION ELISA classic Echinococcus IgG test. Using 10 U/ml as a cut-off point, and serum samples from 50 CE patients and 105 healthy controls, the sensitivity and specificity were 98.0% and 96.2%, respectively. If patients with other infectious diseases were used as negative controls, the specificity decreased to 76.9%, which causes poor positive predictive values. However, if results between 10 and 15 U/ml are classified as indecisive, the specificity of positive results (≥15 U/ml) increased to 92.5% without greatly affecting the sensitivity (92.0%). Using this approach in combination with imaging studies, the SERION ELISA classic Echinococcosis IgG test can be a useful aid in the diagnosis of CE.

  11. Antibiotic susceptibility of methicillin-resistant staphylococci (MRS) of food origin: A comparison of agar disc diffusion method and a commercially available miniaturized test.

    Science.gov (United States)

    Buzón-Durán, Laura; Capita, Rosa; Alonso-Calleja, Carlos

    2018-06-01

    Methicillin-resistant staphylococci (MRS) are a major concern to public and animal health. Thirty MRS (Staphylococcus aureus, S. cohnii, S. epidermidis, S. haemolyticus, S. hominis, S. lentus, S. lugdunensis, S. sciuri, and S. xylosus) isolates from meat and poultry preparations were tested for antimicrobial susceptibility to 11 antimicrobials (belonging to seven different categories) of clinical significance using both the standard agar disc diffusion method and a commercially available miniaturized system (Sensi Test Gram-positive). It is worth stressing that 16 isolates (53.33%) exhibited an extensively drug-resistant phenotype (XDR). The average number of resistances per strain was 4.67. These results suggest that retail meat and poultry preparations are a likely vehicle for the transmission of multi-drug resistant MRS. Resistance to erythromycin was the commonest finding (76.67% of strains), followed by tobramycin, ceftazidime (66.67%), ciprofloxacin (56.67%) and fosfomycin (53.33%). An agreement (kappa coefficient) of 0.64 was found between the two testing methods. Using the agar disc diffusion as the reference method, the sensitivity, specificity and accuracy of the miniaturized test were 98.44%, 69.44% and 83.33%, respectively. Most discrepancies between the two methods were due to isolates that were susceptible according to the disc diffusion method but resistant according to the miniaturized test (false positives). Copyright © 2017. Published by Elsevier Ltd.

  12. Comparative evaluation of effectiveness between Aloe vera and two commercially available mouth rinses on plaque and gingival status: A randomized control trial

    Directory of Open Access Journals (Sweden)

    Sujal Parkar

    2011-01-01

    Full Text Available Aim: Aloe vera has been suggested for a wide variety of ailments, but its use in dentistry is limited. The purpose of the study was to evaluate the effect of A. vera on the reduction of plaque and gingivitis. This effect was evaluated by randomized, parallel and double-blind clinical trial. Materials and Methods: Total 30 subjects were randomly allocated into three groups; 10 in each for (i chlorhexidine, (ii tea tree leaves and (iii A. vera. Plaque index and gingival index were assessed at days 0 and 21. Subjects were asked to rinse their mouth with the mouth rinse, twice a day, during a 21-day period. Paired t-test was used test the mean difference at 0 day and 21 days. One way analysis of variance was used to check the mean difference among three mouth rinses. Results: All three mouth rinses shows a significant reduction from 0 day to 21 days (P 0.05. Conclusion: A. vera mouth rinse was as effective as two commercially popular mouth rinses in controlling plaque and gingivitis.

  13. Characteristics and reference ranges of Insulin-Like Growth Factor-I measured with a commercially available immunoassay in 724 healthy adult Caucasians

    DEFF Research Database (Denmark)

    Andreassen, Mikkel; Nielsen, Kaspar; Raymond, Ilan

    2009-01-01

    BACKGROUND AND OBJECTIVE: Measurements of Insulin-Like Growth Factor-I (IGF-I) play a pivotal role in the evaluation of the growth hormone-IGF-I axis. Due to assay variation IGF-I reference ranges are assay specific. We provide serum IGF-I reference ranges for adult men and women obtained...... by a commercially available assay. METHOD: IGF-I was measured by an enzyme-linked immunosorbent assay (R&D Systems). Assay precision was evaluated in low, medium and high IGF-I pools and in single samples from outpatients. The reference ranges were obtained in 724 healthy Caucasians, mean age 48 years (range 19....../mL (mean 1 SD) were 5, 3 and 3%. Interassays CVs for the low, medium and high pool varied between 7-10, 5-7, and 6-9%. Reproducibility between 4 different lots showed a intraclass CV of 0.99 (95%CI 0.98-0.96). Logarithmically transformed IGF-I levels were linearly associated with age with a 13% reduction...

  14. U-shape rotating anti-cathode compact X-ray generator: 20 times stronger than the commercially available X-ray source

    Energy Technology Data Exchange (ETDEWEB)

    Sakabe, N., E-mail: sakabe-dsb@sbsp.jp; Sakabe, K. [High Energy Accelerator Research Organization (KEK), 1-1 Oho, Tsukuba 305-0801 (Japan); Foundation for Advancement of International Science (FAIS), Kasuga 3-chome, Tsukuba, Ibaraki 305-0821 (Japan); Ohsawa, S.; Sakai, T.; Kobayakawa, H.; Sugimura, T.; Ikeda, M.; Tawada, M. [High Energy Accelerator Research Organization (KEK), 1-1 Oho, Tsukuba, Ibaraki 305-0801 (Japan); Watanabe, N.; Sasaki, K. [Nagoya University, Chikusa, Nagoya, Aichi 464-8603 (Japan); Wakatsuki, M. [National Institute of Advanced Industrial Science and Technology (AIST), 1-1-1 Higashi, Tsukuba, Ibaraki 305-8568 (Japan)

    2013-11-01

    A new type of U-shape anti-cathode X-ray generator in which the inner surface of a cylindrical target is irradiated by an electron beam has been made by modifying a conventional rotating anti-cathode X-ray generator whose brightness in the catalog is 12 kW mm{sup −2}. A brightness of 129 kW mm{sup −2} was thereby obtained with this new U-shape-type X-ray generator. This new X-ray generator is expected to be of keen interest for applications in academia, industry and in hospitals. A new type of U-shape anti-cathode X-ray generator in which the inner surface of a cylindrical target is irradiated by an electron beam has been made by modifying a conventional rotating anti-cathode X-ray generator whose brightness in the catalog is 12 kW mm{sup −2}. The target material (Cu), target radius (50 mm) and rotating speed (6000 r.p.m.) were not changed in this modification. A brightness of 52 kW mm{sup −2} was obtained by this U-shape-type X-ray generator. This means that the brightness of the new type is 4.3 times greater than that of the old unmodified one. Furthermore, the new-type X-ray generator yielded a brightness of 129 kW mm{sup −2} by adding a carbon coating on the Cu target. This means an overall increase of brightness of ten times. The original generator has the highest brightness in the generators of the same class (having a radius of 50 mm and rotation speed of 6000 r.p.m.). Observations showed that Cu Kα counts at vertical incidence of the electron beam onto the surface of the new target, which is initially optically smooth, decrease as the surface is roughened by a severe thermal stress caused by strong electron beam exposure. Further observation reveals, however, that oblique incidence of the electron beam onto the roughened surface drastically increased the X-ray output and amounts to twice as much as that from a smooth surface at vertical incidence. Thus, at the present stage, an overall increase of brightness has been realised at a level 20 times

  15. Randomized double-blind clinical trial of a new human epoetin versus a commercially available formula for anemia control in patients on hemodialysis

    Directory of Open Access Journals (Sweden)

    Paulo D. Picon

    2014-08-01

    Full Text Available OBJECTIVES: Anemia is a common complication among chronic kidney disease patients on hemodialysis, occurring mostly due to erythropoietin deficiency. This randomized noninferiority trial sought to compare the efficacy and safety of a new epoetin formulation developed by Bio-Manguinhos, a biologics manufacturer affiliated with the Brazilian government, with those of a commercially available product currently used in Brazil (a biosimilar epoetin formulation. METHODS: The sample size needed to enable demonstration of noninferiority with a statistical power of 85% for a between-group difference in hemoglobin levels of no more than 1.5 g/dL was calculated. In total, 74 patients were randomly assigned to receive the epoetin formulation from Bio-Manguinhos (n = 36 or the biosimilar epoetin formulation (n = 38 in a double-blind fashion. The inclusion criteria were current epoetin therapy and stable hemoglobin levels for at least 3 months prior to the study. The primary and secondary outcomes were mean monthly hemoglobin levels and safety, respectively. The dose was calculated according to international criteria and adjusted monthly in both groups according to hemoglobin levels and at the assistant physicians' discretion. Iron storage was estimated at baseline and once monthly. Clinicaltrials.gov: NCT01184495. RESULTS: The study was conducted for 6 months after randomization. The mean baseline hemoglobin levels were 10.9±1.2 and 10.96±1.2 g/dL (p = 0.89 in the Bio-Manguinhos epoetin and biosimilar epoetin groups, respectively. During the study period, there was no significant change in hemoglobin levels in either group (p = 0.055, ANOVA. The epoetin from Bio-Manguinhos was slightly superior in the last 3 months of follow-up. The adverse event profiles of the two formulations were also similar. CONCLUSIONS: The epoetin formulations tested in this study are equivalent in efficacy and safety.

  16. A comparison of commercially available demineralized bone matrices with and without human mesenchymal stem cells in a rodent spinal fusion model.

    Science.gov (United States)

    Hayashi, Tetsuo; Lord, Elizabeth L; Suzuki, Akinobu; Takahashi, Shinji; Scott, Trevor P; Phan, Kevin; Tian, Haijun; Daubs, Michael D; Shiba, Keiichiro; Wang, Jeffrey C

    2016-07-01

    OBJECTIVE The efficacy of some demineralized bone matrix (DBM) substances has been demonstrated in the spinal fusion of rats; however, no previous comparative study has reported the efficacy of DBM with human mesenchymal stem cells (hMSCs). There is an added cost to the products with stem cells, which should be justified by improved osteogenic potential. The purpose of this study is to prospectively compare the fusion rates of 3 different commercially available DBM substances, both with and without hMSCs. METHODS Posterolateral fusion was performed in 32 mature athymic nude rats. Three groups of 8 rats were implanted with 1 of 3 DBMs: Trinity Evolution (DBM with stem cells), Grafton (DBM without stem cells), or DBX (DBM without stem cells). A fourth group with no implanted material was used as a control group. Radiographs were obtained at 2, 4, and 8 weeks. The rats were euthanized at 8 weeks. Overall fusion was determined by manual palpation and micro-CT. RESULTS The fusion rates at 8 weeks on the radiographs for Trinity Evolution, Grafton, and DBX were 8 of 8 rats, 3 of 8 rats, and 5 of 8 rats, respectively. A significant difference was found between Trinity Evolution and Grafton (p = 0.01). The overall fusion rates as determined by micro-CT and manual palpation for Trinity Evolution, Grafton, and DBX were 4 of 8 rats, 3 of 8 rats, and 3 of 8 rats, respectively. The Trinity Evolution substance had the highest overall fusion rate, however no significant difference was found between groups. CONCLUSIONS The efficacies of these DBM substances are demonstrated; however, the advantage of DBM with hMSCs could not be found in terms of posterolateral fusion. When evaluating spinal fusion using DBM substances, CT analysis is necessary in order to not overestimate fusion.

  17. Implementation of an Enzyme Linked Immunosorbent Assay for the Quantification of Allergenic Egg Residues in Red Wines Using Commercially Available Antibodies.

    Science.gov (United States)

    Koestel, Carole; Simonin, Céline; Belcher, Sandrine; Rösti, Johannes

    2016-08-01

    Since the early 2000s, labeling of potentially allergenic food components to protect people who suffer from food allergies is compulsory in numerous industrialized countries. In Europe, milk and egg components used during the winemaking process must be indicated on the label since July 1, 2012. Several ELISA procedures have been developed to detect allergenic residues in wines. However, the complexity of the wine matrix can inhibit the immunoenzymatic reaction. The aim of this study was to implement an ELISA assay for the detection of ovalbumin in red wines using commercially available antibodies. The specificity of the acquired antibodies and the absence of cross reactivity were assessed by immunoblotting and ELISA. An ELISA assay with a LOD of 14.2 μg/L and a LOQ of 56.4 μg/L of ovalbumin in aqueous solution was obtained. Differences in ELISA signals were observed when analyzing various fining agents, although reproducible conformation of the antigen could be reached for the comparison of ovalbumin and Ovicolle. The differences between samples in terms of pH could be leveled but the inhibition of the ELISA signal, positively correlated to the tannin content of the wines, could not be suppressed. Thus, standard curves of ovalbumin in several wines were obtained by relative quantification. The control steps and the difficulties encountered presented in this study should be considered by anybody working toward the development of ELISA assays for the detection of allergenic residues in complex food matrices. © 2016 The Authors. Journal of Food Science published by Wiley Periodicals, Inc. on behalf of Institute of Food Technologists.

  18. Isolation and molecular identification of Mycobacterium from commercially available pasteurized milk and raw milk samples collected from two infected cattle farms in Alborz Province, Iran.

    Science.gov (United States)

    Eftekhari, Mohsen; Mosavari, Nader

    2016-12-01

    Mycobacterium avium subsp. paratuberculosis (MAP) is an etiological agent of Johne's disease in ruminant including cattle, sheep and goats. This disease is considered an economically important disease in cattle. Animals with paratuberculosis shed viable MAP, particularly in their milk and feces. MAP may be involved in the development of Crohn's disease in humans through the consumption of contaminated milk and dairy products. Common methods of pasteurization are not enough to kill all MAP present in the milk and the bacterium has been isolated from raw milk, pasteurized milk and cheese samples. The purpose of this study was to evaluate two different methods for detecting MAP in milk and milk products. We analyzed the commonly used methods such as culture and molecular biology for identification of MAP. For this study, 50 milk samples from cows with suspected Johne's disease located in two dairy farms and 10 commercially available pasteurized milk and cheese samples from the market in Karaj city, Iran were selected. Following Ziehl-Neelsen staining of milk samples, direct microscopic detection of MAP was performed. All milk samples were centrifuged, and the concentrated samples were decontaminated using hexadecyl pyridinium chloride. The decontaminated milk suspensions were washed three times by centrifuging, and the collected filtrates were cultivated on Herrold's egg yolk medium enriched by Mycobactin J. Finally, identification and confirmation of isolates to MAP was performed using IS900-nested polymerase chain reaction (PCR). According to the obtained results by culture and PCR methods, none of the pasteurized milk and cheese samples showed the presence of MAP. However, 10% of the tested raw milk samples collected from suspected cattle showed the presence of MAP by both culture and PCR methods. Culture and PCR methods are reliable for identification of MAP from milk samples. Copyright © 2016.

  19. SU-E-T-86: Comparison of Two Commercially Available Programs for the Evaluation of Delivered Daily Dose Using Cone Beam CT (CBCT)

    International Nuclear Information System (INIS)

    Tuohy, R; Bosse, C; Mavroidis, P; Shi, Z; Crownover, R; Papanikolaou, N; Stathakis, S

    2014-01-01

    Purpose: In this study, two commercially available programs were compared for the evaluation of delivered daily dose using cone beam CT (CBCT). Methods: Thirty (n=30) patients previously treated in our clinic (10 prostate, 10 SBRT lung and 10 abdomen) were used in this study. The patients' plans were optimized and calculated using the Pinnacle treatment planning system. The daily CBCT scans were imported into Velocity and RayStation along with the corresponding planning CTs, structure sets and 3D dose distributions for each patient. The organs at risk (OAR) were contoured on each CBCT by the prescribing physician and were included in the evaluation of the daily delivered dose. Each CBCT was registered to the planning CT, once with rigid registration and then again, separately, with deformable registration. After registering each CBCT, the dose distribution from the planning CT was overlaid and the dose volume histograms (DVH) for the OAR and the planning target volumes (PTV) were calculated. Results: For prostate patients, we observed daily volume changes for the OARs. The DVH analysis for those patients showed variation in the sparing of the OARs while PTV coverage remained virtually unchanged using both Velocity and RayStation systems. Similar results were observed for abdominal patients. In contrast, for SBRT lung patients, the DVH for the OARs and target were comparable to those from the initial treatment plan. Differences in organ volume and organ doses were also observed when comparing the daily fractions using deformable and rigid registrations. Conclusion: By using daily CBCT dose reconstruction, we proved PTV coverage for prostate and abdominal targets is adequate. However, there is significant dosimetric change for the OARs. For lung SBRT patients, the delivered daily dose for both PTV and OAR is comparable to the planned dose with no significant differences

  20. Comparison of IgM Capture Enzyme- Linked Immunosorbent Assay (ELISA) using Inhouse method and commercially available MRL kit for serological confirmation of dengue infection

    International Nuclear Information System (INIS)

    Hapugoda, D.M.; De Silva R, Nilanthi; Abeywickreme, W.; Gunasena, Sunethra; Prithimala, L.D.; Jayawardene, S.L.G.J.; Kumari, Thamara

    2003-01-01

    Laboratory diagnosis of dengue infection is important for the management of the patients. In this study igM capture ELISA using an inhouse method and commercially available kit (MRL diagnostics,USA) was compared to detect diagnostic capability of Inhouse IgM ELISA for provision of diagnostic facilities to the public at an affordable cost. Eighty acute and convalescent serum samples were collected from serologically confirmed dengue patients. Serological confirmation of patients were performed by Haemagglutination Inhibition (HI) assay, gold standard assay for dengue on paired serum samples. All collected acute and convalescent sera were tested by IgM ELISA using the inhouse method and MRL kit. Antigen and conjugate for the inhouse IgM method were prepared in the laboratory. A cocktail of four dengue antigens containing 25 Antigen ELISA units of each type was prepared and used as the assay antigen. Conjugate was prepared using a serum sample with high dengue Anti flavi IgG antibody titre conjugated with Horseradish peroxidase. A prospective study of both IgM ELISA assays were performed using 113 acute sera collected from dengue suspected cases. Overall results showed that 46% and 52% acute sera collected from dengue confirmed patients were positive by inhouse ELISA assay and MRL kits respectively. In the prospective study done using acute sera collected from dengue suspected patients showed that 44% and 52% were positive by inhouse ELISA assay and MRL kits. There was no significant difference in positivity between these two assays. (P=0.18). Inhouse IgM ELISA can be used for provision of laboratory diagnosis of dengue virus infection more than 5 days. The assay is 10 times less costly than using MRL kits as assay antigen and conjugate can be prepared easily in the laboratory

  1. AR2, a novel automatic muscle artifact reduction software method for ictal EEG interpretation: Validation and comparison of performance with commercially available software [version 2; referees: 2 approved

    Directory of Open Access Journals (Sweden)

    Shennan Aibel Weiss

    2017-04-01

    Full Text Available Objective: To develop a novel software method (AR2 for reducing muscle contamination of ictal scalp electroencephalogram (EEG, and validate this method on the basis of its performance in comparison to a commercially available software method (AR1 to accurately depict seizure-onset location. Methods: A blinded investigation used 23 EEG recordings of seizures from 8 patients. Each recording was uninterpretable with digital filtering because of muscle artifact and processed using AR1 and AR2 and reviewed by 26 EEG specialists. EEG readers assessed seizure-onset time, lateralization, and region, and specified confidence for each determination. The two methods were validated on the basis of the number of readers able to render assignments, confidence, the intra-class correlation (ICC, and agreement with other clinical findings. Results: Among the 23 seizures, two-thirds of the readers were able to delineate seizure-onset time in 10 of 23 using AR1, and 15 of 23 using AR2 (p<0.01. Fewer readers could lateralize seizure-onset (p<0.05. The confidence measures of the assignments were low (probable-unlikely, but increased using AR2 (p<0.05. The ICC for identifying the time of seizure-onset was 0.15 (95% confidence interval (CI, 0.11-0.18 using AR1 and 0.26 (95% CI 0.21-0.30 using AR2.  The EEG interpretations were often consistent with behavioral, neurophysiological, and neuro-radiological findings, with left sided assignments correct in 95.9% (CI 85.7-98.9%, n=4 of cases using AR2, and 91.9% (77.0-97.5% (n=4 of cases using AR1. Conclusions: EEG artifact reduction methods for localizing seizure-onset does not result in high rates of interpretability, reader confidence, and inter-reader agreement. However, the assignments by groups of readers are often congruent with other clinical data. Utilization of the AR2 software method may improve the validity of ictal EEG artifact reduction.

  2. Validation of a Commercially Available Enzyme ImmunoAssay for the Determination of Oxytocin in Plasma Samples from Seven Domestic Animal Species

    Directory of Open Access Journals (Sweden)

    Cecile Bienboire-Frosini

    2017-09-01

    Full Text Available The neurohormone oxytocin (OT has a broad range of behavioral effects in mammals. It modulates a multitude of social behaviors, e.g., affiliative and sexual interactions. Consequently, the OT role in various animal species is increasingly explored. However, several issues have been raised regarding the peripheral OT measurement. Indeed, various methods have been described, leading to assay discrepancies and inconsistent results. This highlights the need for a recognized and reliable method to measure peripheral OT. Our aim was to validate a method combining a pre-extraction step, previously demonstrated as essential by several authors, and a commercially available enzyme immunoassay (EIA for OT measurement, using plasma from seven domestic species (cat, dog, horse, cow, pig, sheep, and goat. The Oxytocin EIA kit (EnzoLifeSciences was used to assay the solid-phase extracted samples following the manufacturer's instructions with slight modifications. For all species except dogs and cats, concentration factors were applied to work above the kit's sensitivity (15 pg/ml. To validate the method, the following performance characteristics were evaluated using Validation Samples (VS at various concentrations in each species: extraction efficiency via spiking tests and intra- and inter-assay precision, allowing for the calculation of total errors. Parallelism studies to assess matrix effects could not be performed because of too low basal concentrations. Quantification ranges and associated precision profiles were established to account for the various OT plasma concentrations in each species. According to guidelines for bioanalytical validation of immunoassays, the measurements were sufficiently precise and accurate in each species to achieve a total error ≤30% in each VS sample. In each species, the inter-assay precision after 3 runs was acceptable, except in low concentration samples. The linearity under dilution of dogs and cats' samples was

  3. Measuring factor IX activity of nonacog beta pegol with commercially available one-stage clotting and chromogenic assay kits: a two-center study.

    Science.gov (United States)

    Bowyer, A E; Hillarp, A; Ezban, M; Persson, P; Kitchen, S

    2016-07-01

    Essentials Validated assays are required to precisely measure factor IX (FIX) activity in FIX products. N9-GP and two other FIX products were assessed in various coagulation assay systems at two sites. Large variations in FIX activity measurements were observed for N9-GP using some assays. One-stage and chromogenic assays accurately measuring FIX activity for N9-GP were identified. Background Measurement of factor IX activity (FIX:C) with activated partial thromboplastin time-based one-stage clotting assays is associated with a large degree of interlaboratory variation in samples containing glycoPEGylated recombinant FIX (rFIX), i.e. nonacog beta pegol (N9-GP). Validation and qualification of specific assays and conditions are necessary for the accurate assessment of FIX:C in samples containing N9-GP. Objectives To assess the accuracy of various one-stage clotting and chromogenic assays for measuring FIX:C in samples containing N9-GP as compared with samples containing rFIX or plasma-derived FIX (pdFIX) across two laboratory sites. Methods FIX:C, in severe hemophilia B plasma spiked with a range of concentrations (from very low, i.e. 0.03 IU mL(-1) , to high, i.e. 0.90 IU mL(-1) ) of N9-GP, rFIX (BeneFIX), and pdFIX (Mononine), was determined at two laboratory sites with 10 commercially available one-stage clotting assays and two chromogenic FIX:C assays. Assays were performed with a plasma calibrator and different analyzers. Results A high degree of variation in FIX:C measurement was observed for one-stage clotting assays for N9-GP as compared with rFIX or pdFIX. Acceptable N9-GP recovery was observed in the low-concentration to high-concentration samples tested with one-stage clotting assays using SynthAFax or DG Synth, or with chromogenic FIX:C assays. Similar patterns of FIX:C measurement were observed at both laboratory sites, with minor differences probably being attributable to the use of different analyzers. Conclusions These results suggest that, of the

  4. Validation of a Commercially Available Enzyme ImmunoAssay for the Determination of Oxytocin in Plasma Samples from Seven Domestic Animal Species.

    Science.gov (United States)

    Bienboire-Frosini, Cecile; Chabaud, Camille; Cozzi, Alessandro; Codecasa, Elisa; Pageat, Patrick

    2017-01-01

    The neurohormone oxytocin (OT) has a broad range of behavioral effects in mammals. It modulates a multitude of social behaviors, e.g., affiliative and sexual interactions. Consequently, the OT role in various animal species is increasingly explored. However, several issues have been raised regarding the peripheral OT measurement. Indeed, various methods have been described, leading to assay discrepancies and inconsistent results. This highlights the need for a recognized and reliable method to measure peripheral OT. Our aim was to validate a method combining a pre-extraction step, previously demonstrated as essential by several authors, and a commercially available enzyme immunoassay (EIA) for OT measurement, using plasma from seven domestic species (cat, dog, horse, cow, pig, sheep, and goat). The Oxytocin EIA kit (EnzoLifeSciences) was used to assay the solid-phase extracted samples following the manufacturer's instructions with slight modifications. For all species except dogs and cats, concentration factors were applied to work above the kit's sensitivity (15 pg/ml). To validate the method, the following performance characteristics were evaluated using Validation Samples (VS) at various concentrations in each species: extraction efficiency via spiking tests and intra- and inter-assay precision, allowing for the calculation of total errors. Parallelism studies to assess matrix effects could not be performed because of too low basal concentrations. Quantification ranges and associated precision profiles were established to account for the various OT plasma concentrations in each species. According to guidelines for bioanalytical validation of immunoassays, the measurements were sufficiently precise and accurate in each species to achieve a total error ≤30% in each VS sample. In each species, the inter-assay precision after 3 runs was acceptable, except in low concentration samples. The linearity under dilution of dogs and cats' samples was verified. Although

  5. Comparison of three commercially available prescription diet regimens on short-term post-prandial serum glucose and insulin concentrations in healthy cats.

    Science.gov (United States)

    Mori, A; Sako, T; Lee, P; Nishimaki, Y; Fukuta, H; Mizutani, H; Honjo, T; Arai, T

    2009-10-01

    Dietary therapy is an important treatment component for diabetes mellitus (DM). In this study, the impact of three different commercially available diet regiments (1 general use and 2 aimed for treating obesity and DM) on short-term post-prandial serum glucose and insulin concentrations of five healthy cats to better understand what impact each of these diets may have for diabetic cats. The diet regiments used in this study were as follows: C/D dry (General Use- Low protein, High fat, High carbohydrate, and Low fiber), M/D dry (DM- High protein, High fat, Low carbohydrate, and High Fiber), and W/D dry (DM- Low Protein, Low Fat, High Carbohydrate, and High Fiber). No significant difference in post-prandial serum glucose levels were observed with the C/D (84.6 +/- 1.5 mg/dl) and W/D (83.8 +/- 1.4 mg/dl) dry diets when compared to pre-prandial fasting levels (83.9 +/- 1.4 mg/dl). However, a significant reduction was observed with the M/D diet (78.9 +/- 0.8 mg/dl) which had 50-60% less carbohydrates than either C/D or W/D diet. Unlike what was observed with post-prandial glucose levels, an interesting pattern emerged with post-prandial insulin levels, which were increasing with W/D, C/D, and M/D diets in that order (1.1 +/- 0.2, 1.7 +/- 0.2, and 2.3 +/- 0.2 ng/ml respectively). Most surprising, though, was the fact that the W/D diet did not seem to stimulate insulin secretion as compared to pre-prandial levels (1.1 +/- 0.1 ng/ml) in healthy cats. Interestingly, the W/D diet had high levels of carbohydrate and low levels of protein. Coincidentally, the only diet (M/D) which had a significant reduction in post-prandial glucose also showed the highest increase in post-prandial insulin in healthy cats. Therefore, dietary amounts of carbohydrate, fat, protein and fiber can all have an individual impact on post-prandial glycemia and subsequent insulin requirement levels. Just as concepts regarding dietary management of people with DM are evolving, investigators are

  6. Short-term comparison between extended depth-of-focus prototype contact lenses and a commercially-available center-near multifocal.

    Science.gov (United States)

    Tilia, Daniel; Munro, Anna; Chung, Jiyoon; Sha, Jennifer; Delaney, Shona; Kho, Danny; Thomas, Varghese; Ehrmann, Klaus; Bakaraju, Ravi Chandra

    To compare the visual performance of prototype contact lenses which extend depth-of-focus (EDOF) by deliberate manipulation of multiple higher-order spherical aberration terms and a commercially-available center-near lens (AIR OPTIX Aqua Multifocal, AOMF). This was a prospective, cross-over, randomized, single-masked (participant), short-term clinical trial where 52 participants (age 45-70 years) were stratified as low, medium or high presbyopes and wore EDOF and AOMF on different days. Objective measures comprised high and low contrast visual acuity (HCVA/LCVA, logMAR), and contrast sensitivity (log units) at 6m; HCVA at 70cm, 50cm and 40cm and stereopsis (seconds of arc) at 40cm. HCVA at 70cm, 50cm and 40cm were measured as "comfortable acuity" rather than conventional resolution acuity. Subjective measures comprised clarity-of-vision and ghosting at distance, intermediate and near, overall vision satisfaction and ocular comfort (1-10 numeric rating scale) and lens purchase (yes/no response). Statistical analysis included repeated measures ANOVA, paired t-tests and McNemar's test. Significant differences between lens types were independent of strata (p≥0.119). EDOF was significantly better than AOMF for HCVA at 40cm (0.42±0.18 vs. 0.48±0.22, p=0.024), stereopsis (98±88 vs. 141±114, p<0.001), clarity-of-vision at intermediate (8.5±1.6 vs. 7.7±1.9, p=0.006) and near (7.3±2.5 vs. 6.2±2.5, p=0.005), lack-of-ghosting (p=0.012), overall vision satisfaction (7.5±1.7 vs. 6.4±2.2, p<0.001) and ocular comfort (9.0±1.0 vs. 8.3±1.7, p=0.002). Significantly more participants chose to only-purchase EDOF (33% vs. 6%, p=0.003).). There were no significant differences between lens types for any objective measure at 6m or clarity-of-vision at distance (p≥0.356). EDOF provides better intermediate and near vision performance in presbyopes than AOMF with no difference for distance vision during short-term wear. Copyright © 2016 Spanish General Council of Optometry

  7. Energy compensation in the real world: good compensation for small portions of chocolate and biscuits over short time periods in complicit consumers using commercially available foods.

    Science.gov (United States)

    Appleton, Katherine M; McKeown, Pascal P; Woodside, Jayne V

    2015-02-01

    While investigations using covert food manipulations tend to suggest that individuals are poor at adjusting for previous energy intake, in the real world adults rarely consume foods of which they are ill-informed. This study investigated the impact in fully complicit consumers of consuming commercially available dark chocolate, milk chocolate, sweet biscuits and fruit bars on subsequent appetite. Using a repeated measures design, participants received four small portions (4 × 10-11 g) of either dark chocolate, milk chocolate, sweet biscuits, fruit bars or no food throughout five separate study days (counterbalanced in order), and test meal intake, hunger, liking and acceptability were measured. Participants consumed significantly less at lunch following dark chocolate, milk chocolate and sweet biscuits compared to no food (smallest t(19) = 2.47, p = 0.02), demonstrating very good energy compensation (269-334%). No effects were found for fruit bars (t(19) = 1.76, p = 0.09), in evening meal intakes (F(4,72) = 0.62, p = 0.65) or in total intake (lunch + evening meal + food portions) (F(4,72) = 0.40, p = 0.69). No differences between conditions were found in measures of hunger (largest F(4,76) = 1.26, p = 0.29), but fruit bars were significantly less familiar than all other foods (smallest t(19) = 3.14, p = 0.01). These findings demonstrate good compensation over the short term for small portions of familiar foods in complicit consumers. Findings are most plausibly explained as a result of participant awareness and cognitions, although the nature of these cognitions cannot be discerned from this study. These findings however, also suggest that covert manipulations may have limited transfer to real world scenarios. Copyright © 2014 Elsevier Ltd. All rights reserved.

  8. Serologic response of roosters to gradient dosage levels of a commercially available live F strain-derived Mycoplasma gallisepticum vaccine over time

    Science.gov (United States)

    Spray application is a commonly used time- and labor-efficient means to deliver live Mycoplasma gallisepticum (MG) vaccine to laying hens in commercial production facilities. The dosage of vaccine received by spray vaccinated birds can vary due to variation in the spray plume and vaccine suspension...

  9. More features, greater connectivity.

    Science.gov (United States)

    Hunt, Sarah

    2015-09-01

    Changes in our political infrastructure, the continuing frailties of our economy, and a stark growth in population, have greatly impacted upon the perceived stability of the NHS. Healthcare teams have had to adapt to these changes, and so too have the technologies upon which they rely to deliver first-class patient care. Here Sarah Hunt, marketing co-ordinator at Aid Call, assesses how the changing healthcare environment has affected one of its fundamental technologies - the nurse call system, argues the case for wireless such systems in terms of what the company claims is greater adaptability to changing needs, and considers the ever-wider range of features and functions available from today's nurse call equipment, particularly via connectivity with both mobile devices, and ancillaries ranging from enuresis sensors to staff attack alert 'badges'.

  10. Computational Tools and Resources for Metabolism-Related Property Predictions. 1. Overview of Publicly Available (Free and Commercial) Databases and Software

    Science.gov (United States)

    2012-01-01

    inhibitors, kinetics, UGT substrates, clearance QSAR models [211] ADMEworks Predictor Fujitsu Commercial CYP-binding affinities QSAR models [253] CypScore...fragment energies pre- calculated using density functional theory . The second descriptor is a measure of how far each site is from the center of the...semiempirical molecular orbital theory . ChemMedChem 4(4), 657–669 (2009). 44 Rydberg P, Gloriam DE, Zaretzki J, Breneman C, Olsen L. SMARTCyp: A 2D method for

  11. Ammonium accumulation in commercially available embryo culture media and protein supplements during storage at 2-8°C and during incubation at 37°C.

    Science.gov (United States)

    Kleijkers, Sander H M; van Montfoort, Aafke P A; Bekers, Otto; Coonen, Edith; Derhaag, Josien G; Evers, Johannes L H; Dumoulin, John C M

    2016-06-01

    Does ammonium accumulate in commercially available culture media and protein supplements used for in vitro development of human pre-implantation embryos during storage and incubation? Ammonium accumulates in ready-to-use in vitro fertilization (IVF) culture media during storage at 2-8°C and in ready-to-use IVF culture media and protein supplements during incubation at 37°C. Both animal and human studies have shown that the presence of ammonium in culture medium has detrimental effects on embryonic development and pregnancy rate. It is, therefore, important to assess the amount of ammonium accumulation in ready-to-use IVF culture media under conditions that are common in daily practice. Ammonium accumulation was investigated in 15 ready-to-use media, 11 protein-free media and 8 protein supplements. Ammonium was measured by the use of an enzymatic method with glutamate dehydrogenase. To simulate the storage and incubation conditions during IVF treatments, ammonium concentrations were measured at different time-points during storage at 2-8°C for 6 weeks and during incubation at 37°C for 4 days. All ready-to-use, i.e. protein supplemented, culture media showed ammonium accumulation during storage for 6 weeks (ranging from 9.2 to 99.8 µM) and during incubation for 4 days (ranging from 8.4 to 138.6 µM), resulting in levels that might affect embryo development. The protein supplements also showed ammonium accumulation, while the culture media without protein supplementation did not. The main sources of ammonium buildup in ready-to-use culture media were unstable glutamine and the protein supplements. No additional ammonium buildup was found during incubation when using an oil overlay or with the presence of an embryo in the culture droplet. In addition to the unstable glutamine and the protein supplements, other free amino acids might contribute to the ammonium buildup. We did not investigate the deterioration of other components in the media. Break-down of

  12. Commercial Integrated Heat Pump with Thermal Storage --Demonstrate Greater than 50% Average Annual Energy Savings, Compared with Baseline Heat Pump and Water Heater (Go/No-Go) FY16 4th Quarter Milestone Report

    Energy Technology Data Exchange (ETDEWEB)

    Shen, Bo [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Baxter, Van D. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Rice, C. Keith [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Abu-Heiba, Ahmad [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States)

    2017-03-01

    For this study, we authored a new air source integrated heat pump (AS-IHP) model in EnergyPlus, and conducted building energy simulations to demonstrate greater than 50% average energy savings, in comparison to a baseline heat pump with electric water heater, over 10 US cities, based on the EnergyPlus quick-service restaurant template building. We also assessed water heating energy saving potentials using ASIHP versus gas heating, and pointed out climate zones where AS-IHPs are promising.

  13. Cassava flour slurry as a low-cost alternative to commercially available gel for obstetrical ultrasound: a blinded non-inferiority trial comparison of image quality.

    Science.gov (United States)

    Aziz, A; Dar, P; Hughes, F; Solorzano, C; Muller, M M; Salmon, C; Salmon, M; Benfield, N

    2018-01-12

    To evaluate the quality of ultrasound images obtained with cassava flour slurry (CFS) compared with conventional gel in order to determine objectively whether CFS could be a true low-cost alternative. Blinded non-inferiority trial. Obstetrical ultrasound unit in an academic medical centre. Women with a singleton pregnancy, undergoing anatomy ultrasounds. Thirty pregnant women had standard biometry measures obtained with CFS and conventional gel. Images were compared side-by-side in random order by two blinded sonologists and rated for image resolution, detail and total image quality using a 10-cm visual analogue scale. Ratings were compared using paired t-tests. Participant and sonographer experience was measured using five-point Likert scales. Image resolution, detail, and total image quality. Participant experience of gel regarding irritation, messiness, and ease of removal. We found no significant difference between perceived image quality obtained with CFS (mean = 6.2, SD = 1.2) and commercial gel (mean = 6.4, SD = 1.2) [t (28) = -1.1; P = 0.3]. Images were not rated significantly differently for either reviewer in any measure, any standardized image or any view of a specific anatomic structure. All five sonographers rated CFS as easy to obtain clear images and easy for patient and machine cleanup. Only one participant reported itching with CFS. CFS produces comparable image quality to commercial ultrasound gel. The dissemination of these results and the simple CFS recipe could significantly increase access to ultrasound for screening, monitoring and diagnostic purposes in resource-limited settings. This study was internally funded by our department. Low-cost homemade cassava flour slurry creates images equal to commercial ultrasound gel, improving access. © 2018 Royal College of Obstetricians and Gynaecologists.

  14. Evaluation of commercially available enzymes, probiotics, or yeast on apparent total-tract nutrient digestion and growth in nursery and finishing pigs fed diets containing corn dried distillers grains with solubles

    Science.gov (United States)

    The ability of enzymes, direct fed microbials, or yeast to enhance nutrient utilization or growth performance in nursery or finishing pigs fed diets containing increased levels of corn fiber from dried distillers grains with solubles (DDGS) is largely unknown. Ten commercially available feed additiv...

  15. Commercially available media for flushing extracorporeal bioartificial liver systems prior to connection to the patient's circulation: an in vitro comparative study in two and three dimensional porcine hepatocyte cultures

    NARCIS (Netherlands)

    Flendrig, L. M.; Sommeijer, D.; Ladiges, N. C.; te Velde, A. A.; Maas, M. A.; Jörning, G. G.; Daalhuisen, J.; Chamuleau, R. A.

    1998-01-01

    Extracorporeal bioartificial liver (BAL) systems based on hepatocytes need to be flushed before clinical application, as hepatocyte culture media are not approved for medical use. Commercially available 0.9% NaCl solution and hemofiltration solution (both supplemented with 10% human albumin) were

  16. Six potencial woods for bows of stringed instruments: organoleptic properties, machining and commercial availability. Seis madeiras potenciais para arcos de instrumentos de corda: propriedades organolépticas, trababilidade e disponibilidade comercial.

    Directory of Open Access Journals (Sweden)

    Eduardo Luiz LONGUI

    2011-12-01

    Full Text Available In this paper it was investigated the organoleptic properties and machining of six potential woods for bows of stringed instruments and compared the results with those mentioned for the Caesalpinia echinata wood, the reference for modern bows. Thirty wood stores were visited in different cities of the São Paulo state to verify the commercial availability of these woods. We concluded that despite the traditionalism of the red tones in the woods for bows, woods with yellowish tones such as Handroanthus spp. and Dipteryx spp. or brownish such as Diplotropis spp. with appropriate properties, may offer alternative colors and textures to the musicians. It was observed that the Mezilaurus itauba and Astronium lecointei, woods with easy machining, have no potential suitable for bows. Regarding to availability, all woods tested are relatively easy to find nowadays in the wood market. Handroanthus spp. and Dipteryx spp. showed greater potential for making bows for professional musicians.The woods of Mezilaurus itauba and Astronium lecointei did not show good potentialfor bows.Neste trabalho foram investigadas as propriedades organolépticas e a trabalhabilidade de seis madeiras potenciais para arcos de instrumentos de corda e os resultados comparados com os da madeira de Caesalpinia echinata, referência para arcos modernos. Foram visitadas 30 madeireiras em diferentes cidades do Estado de São Paulo para observar a disponibilidade das seis madeiras. Conclui-se que apesar do tradicionalismo dos tons de vermelhos na madeira para arcos, outras madeiras com tons amarelados como Handroanthus spp. e Dipteryx spp. ou acastanhados como Diplotropis spp., desde que possuam propriedades adequadas, podem oferecer alternativas de cores e texturas para os músicos. Madeiras de fácil trabalhabilidade, como Mezilaurus itauba e Astronium lecointei não são adequadas para a fabricação dos arcos. Atualmente, todas as madeiras testadas são relativamente fáceis de

  17. A novel approach to background subtraction in contrast-enhanced dual-energy digital mammography with commercially available mammography devices: Noise minimization

    International Nuclear Information System (INIS)

    Contillo, Adriano; Di Domenico, Giovanni; Cardarelli, Paolo; Gambaccini, Mauro; Taibi, Angelo

    2016-01-01

    Purpose: Dual-energy image subtraction represents a useful tool to improve the detectability of small lesions, especially in dense breasts. A feature it shares with all x-ray imaging techniques is the appearance of fluctuations in the texture of the background, which can obscure the visibility of interesting details. The aim of the work is to investigate the main noise sources, in order to create a better performing subtraction mechanism. In particular, the structural noise cancellation was achieved by means of a suitable extension of the dual-energy algorithm. Methods: The effect of the cancellation procedure was tested on an analytical simulation of a target with varying structural composition. Subsequently, the subtraction algorithm was also applied to a set of actual radiographs of a breast phantom exhibiting a nonuniform background pattern. The background power spectra of the outcomes were computed and compared to the ones obtained from a standard subtraction algorithm. Results: The comparison between the standard and the proposed cancellations showed an overall suppression of the magnitudes of the spectra, as well as a flattening of the frequency dependence of the structural component of the noise. Conclusions: The proposed subtraction procedure provides an effective cancellation of the residual background fluctuations. When combined with the polychromatic correction already described in a companion publication, it results in a high performing dual-energy subtraction scheme for commercial mammography units.

  18. Comparative trial of the canine parvovirus, canine distemper virus and canine adenovirus type 2 fractions of two commercially available modified live vaccines.

    Science.gov (United States)

    Bergman, J G H E; Muniz, M; Sutton, D; Fensome, R; Ling, F; Paul, G

    2006-11-25

    The results of vaccinating two groups of puppies with commercial vaccines, both of which claimed to provide adequate protection with a final vaccination at 10 weeks of age, were compared. Groups of 19 and 20 puppies with similar titres of maternally derived antibodies against canine parvovirus (cpv), canine distemper virus (cdv) and canine adenovirus type 2 (cav-2) at four weeks of age were vaccinated at six and 10 weeks of age and their responses to each vaccination were measured by comparing the titres against cpv, cdv and cav-2 in the serum samples taken immediately before the vaccination and four weeks later. After the vaccination at six weeks of age, all 19 of the puppies in group 1 had responded to cpv and cdv, and 14 had responded to cav-2; in group 2, 17 of the 20 had responded to cpv, 19 to cdv and 15 to cav-2. In both groups the puppies that did not respond to the first vaccination had responded serologically to cpv, cdv and cav-2 at 10 weeks of age.

  19. A novel approach to background subtraction in contrast-enhanced dual-energy digital mammography with commercially available mammography devices: Noise minimization

    Energy Technology Data Exchange (ETDEWEB)

    Contillo, Adriano, E-mail: contillo@fe.infn.it; Di Domenico, Giovanni; Cardarelli, Paolo; Gambaccini, Mauro; Taibi, Angelo [Dipartimento di Fisica e Scienze della Terra, Università degli Studi di Ferrara, Via Saragat 1, I-44122 Ferrara (Italy)

    2016-06-15

    Purpose: Dual-energy image subtraction represents a useful tool to improve the detectability of small lesions, especially in dense breasts. A feature it shares with all x-ray imaging techniques is the appearance of fluctuations in the texture of the background, which can obscure the visibility of interesting details. The aim of the work is to investigate the main noise sources, in order to create a better performing subtraction mechanism. In particular, the structural noise cancellation was achieved by means of a suitable extension of the dual-energy algorithm. Methods: The effect of the cancellation procedure was tested on an analytical simulation of a target with varying structural composition. Subsequently, the subtraction algorithm was also applied to a set of actual radiographs of a breast phantom exhibiting a nonuniform background pattern. The background power spectra of the outcomes were computed and compared to the ones obtained from a standard subtraction algorithm. Results: The comparison between the standard and the proposed cancellations showed an overall suppression of the magnitudes of the spectra, as well as a flattening of the frequency dependence of the structural component of the noise. Conclusions: The proposed subtraction procedure provides an effective cancellation of the residual background fluctuations. When combined with the polychromatic correction already described in a companion publication, it results in a high performing dual-energy subtraction scheme for commercial mammography units.

  20. A novel approach to background subtraction in contrast-enhanced dual-energy digital mammography with commercially available mammography devices: Polychromaticity correction

    Energy Technology Data Exchange (ETDEWEB)

    Contillo, Adriano, E-mail: contillo@fe.infn.it; Di Domenico, Giovanni; Cardarelli, Paolo; Gambaccini, Mauro; Taibi, Angelo [Dipartimento di Fisica e Scienze della Terra, Università degli Studi di Ferrara, Via Saragat 1, Ferrara I-44122 (Italy)

    2015-11-15

    Purpose: Contrast-enhanced digital mammography is an image subtraction technique that is able to improve the detectability of lesions in dense breasts. One of the main sources of error, when the technique is performed by means of commercial mammography devices, is represented by the intrinsic polychromaticity of the x-ray beams. The aim of the work is to propose an iterative procedure, which only assumes the knowledge of a small set of universal quantities, to take into account the polychromaticity and correct the subtraction results accordingly. Methods: In order to verify the procedure, it has been applied to an analytical simulation of a target containing a contrast medium and to actual radiographs of a breast phantom containing cavities filled with a solution of the same medium. Results: The reconstructed densities of contrast medium were compared, showing very good agreement between the theoretical predictions and the experimental results already after the first iteration. Furthermore, the convergence of the iterative procedure was studied, showing that only a small number of iterations is necessary to reach limiting values. Conclusions: The proposed procedure represents an efficient solution to the polychromaticity issue, qualifying therefore as a viable alternative to inverse-map functions.

  1. Laboratory and Field Testing of Commercially Available Detectors for the Identification of Chemicals of Interest in the Nuclear Fuel Cycle for the Detection of Undeclared Activities

    Energy Technology Data Exchange (ETDEWEB)

    Carla Miller; Mary Adamic; Stacey Barker; Barry Siskind; Joe Brady; Warren Stern; Heidi Smartt; Mike McDaniel; Mike Stern; Rollin Lakis

    2014-07-01

    then identified commercial off the shelf (COTS) chemical detectors that may detect the chemicals of interest. Three chemical detectors were selected and tested both in laboratory settings and in field operations settings at Idaho National Laboratory. The instruments selected are: Thermo Scientific TruDefender FT (FTIR), Thermo Scientific FirstDefender RM (Raman), and Bruker Tracer III SD (XRF). Functional specifications, operability, and chemical detectability, selectivity, and limits of detection were determined. Results from the laboratory and field tests will be presented. This work is supported by the Next Generation Safeguards Initiative, Office of Nonproliferation and International Security, National Nuclear Security Administration.

  2. Comparison of dry, wet and microwave digestion methods for the determination of Pb in commercially available poultry feed samples in Pakistan

    International Nuclear Information System (INIS)

    Iqbal, S.; Hussain, A.; Hussain, I.; Sher, M.

    2012-01-01

    Summary: The poultry feed ingredients, contaminated by Lead (Pb) from different sources, may pose serious threats towards health of bird as well as consumers. Toxicity of Pb requires accurate quantification from poultry samples, which in turn is dependent on efficiency of digestion procedure. Therefore, aim of this study was to compare three main digestion methods; microwave-assisted wet digestion, wet-acid digestion on hot plate and dry ashing mineralization in muffle furnace for the maximum recovery of Pb from 28 poultry feed samples of 7 commercial brands from Pakistan. Novelty in wet-acid digestion on hot plate lies in applying 6 different compositions of nitric acid with oxidants and other mineral acids i.e. hydrogen peroxide (H/sub 2/O/sub 2/ ), perchloric (HClO/sub 4/), hydrochloric (HCl), and hydrofluoric (HF) acids. The concentration of Pb in samples was found to be in the range of 43-58.5, 26-35.5, 17- 30, 11-18.5, 22-30.5, 27-37 .5, 36-48 and 2- 6.5 mg/kg by 1 MW (microwave-assisted wet digestion), 2 AW (wet digestion with HNO/sub 3/ and H/sub 2/O/sub 2/ mixture), 2 BW (wet digestion with mixture of HNO/sub 3/ and HClO/sub 4/), 2 CW (wet digestion with aqua regia), 2 DW (wet digestion with reverse aqua regia), 2 EW (wet digestion with mixture of HNO/sub 3/ and H/sub 2/SO/sub 4/), 2 FW (wet digestion with mixture of HNO/sub 3/ and HF) and 3 DD (Dry digestion in Muffle furnace), respectively. The results were subjected to statistical analysis i.e. ANOVA, which showed significant differences among all the digestion methods and cluster analysis, which confirmed the similarity between 2 FW (wet digestion with mixture of nitric acid and hydrofluoric acid) and microwave-assisted digestion method. (author)

  3. A comparative study on laser processing of commercially available titanium aluminide (TI-48AL-2CR-2NB) and in-situ alloying of titanium aluminide

    CSIR Research Space (South Africa)

    Hoosain, Shaik E

    2017-11-01

    Full Text Available Titanium aluminides (TiAl) are acknowledged as promising high temperature structural materials due to their high melting point, high strength to density, high elastic modulus and high creep strength. Due to their low ductility, it is difficult...

  4. Greater autonomy at work

    NARCIS (Netherlands)

    Houtman, I.L.D.

    2004-01-01

    In the past 10 years, workers in the Netherlands increasingly report more decision-making power in their work. This is important for an economy in recession and where workers face greater work demands. It makes work more interesting, creates a healthier work environment, and provides opportunities

  5. Spectrophotometric Analysis of the Kinetic of Pd(II Chloride Complex Ions Sorption Process from Diluted Aqua Solutions Using Commercially Available Activated Carbon

    Directory of Open Access Journals (Sweden)

    Wojnicki M.

    2017-12-01

    Full Text Available In this paper, results of adsorption kinetic studies of Pd(II chloride complex ions on activated carbon Organosrob 10 CO are presented. Spectorphotometrical method was applied to investigate the process. Kinetic model was proposed, and fundamental thermodynamic parameters were determined. Proposed kinetic model describes well observed phenomenon in the studied range of concentration of Pd(II chloride complex ions as well, as concentration of activated carbon.

  6. Commercially available avian and mammalian whole prey diet items targeted for consumption by managed exotic and domestic pet felines: true metabolizable energy and amino acid digestibility using the precision-fed cecectomized rooster assay.

    Science.gov (United States)

    Kerr, K R; Kappen, K L; Garner, L M; Utterback, P L; Parsons, C M; Swanson, K S

    2014-10-01

    Whole prey diets are commonly used in the zoo and home setting for captive exotic and domestic cats, respectively. Despite their increase in popularity, nutrient digestibility of such diets has been poorly studied. In this study, the precision-fed cecectomized rooster assay was used to determine the protein quality and nitrogen-corrected true ME (TMEn) of 17 whole prey samples (mice [1 to 2 , 10 to 13 , 21 to 25 , 30 to 40 , and 150 to 180 d old], rats [1 to 4, 10 to 13, 21 to 25, 32 to 42, and >60 d old], rabbits [stillborn, 30 to 45 d old, and >65 d old], chicken [1 to 3 d old], and quail [1 to 3, 21 to 40, and >60 d old]) and 2 ground poultry-based products (chicken and duck). Amino acid score (AAS) and protein digestibility corrected AAS (PDCAAS) were calculated using the nutrient profile recommendations for domestic cat food as a reference value (AAFCO, 2012). Average individual indispensable AA (IAA) and total IAA (TIAA) digestibility coefficients were variable anddepended on AA (84 to 94% TIAA, 85 to 95% Arg, 87 to 96% His, 82 to 92% Ile, 84 to 94% Leu, 85 to 93% Lys, 89 to 97% Met, 83 to 94% Phe, 80 to 95% Thr, 84 to 94% Trp, and 80 to 93% Val) and sample. For a majority of the whole prey items, AA concentrations were greater than the Association of American Feed Control Officials ( AAFCO: , 2012) domestic cat nutrient profile recommendations for growth and reproduction and adult maintenance; however, some whole prey had AA concentrations below the AAFCO (2012) recommendations: Met + Cys (1.10% DM) in ground duck (1.06% DM) and taurine (Tau; 0.20% DM) in 30-to-45- and >65-d-old rabbits (0.01 and 0.10% DM, respectively), 150-to-180-d-old mice (0.18% DM), and ground duck (0.15% DM). The TMEn (3.76 to 6.44 kcal/g DM) expressed as the percent of GE (i.e., TMEn/GE) ranged from 66 to 85%, demonstrating how variable the digestibility of these items may be and justifying more research in this area. Both Met and Tau are commonly added to commercial pet foods, so

  7. Therapeutic ultrasound as a potential male contraceptive: power, frequency and temperature required to deplete rat testes of meiotic cells and epididymides of sperm determined using a commercially available system

    OpenAIRE

    Tsuruta James K; Dayton Paul A; Gallippi Caterina M; O'Rand Michael G; Streicker Michael A; Gessner Ryan C; Gregory Thomas S; Silva Erick JR; Hamil Katherine G; Moser Glenda J; Sokal David C

    2012-01-01

    Abstract Background Studies published in the 1970s by Mostafa S. Fahim and colleagues showed that a short treatment with ultrasound caused the depletion of germ cells and infertility. The goal of the current study was to determine if a commercially available therapeutic ultrasound generator and transducer could be used as the basis for a male contraceptive. Methods Sprague-Dawley rats were anesthetized and their testes were treated with 1 MHz or 3 MHz ultrasound while varying power, duration ...

  8. Assessing the acidity and total sugar content of four different commercially available beverages commonly consumed by children and its time-dependent effect on plaque and salivary pH

    OpenAIRE

    Abhishek Jha; G Radha; R Rekha; S K Pallavi

    2015-01-01

    Introduction: Sugared beverages such as cola, packaged juice, are known for cariogenicity their intake leads to the immediate drop in plaque and salivary pH, which can be an etiologic factor for dental caries. Objective: The objective was to assess the endogenous acidity and total sugar content of four commercially available beverages commonly consumed by children in India and its effect on salivary and plaque pH. Materials and Methods: A crossover controlled trial was conducted. 60 randomly ...

  9. Greater food availability reduces tarsus assymmetry in nestling Blue Tits

    NARCIS (Netherlands)

    Grieco, F.

    2003-01-01

    Previous work has shown that the quantity or quality of food affects the degree of asymmetry in bilateral body traits in adult birds, but so far there is no evidence that this is the case in early phases of growth too. I studied asymmetry of tarsus length of nestling Blue Tits (Parus caeruleus) in

  10. Plant-availability to barley of phosphorus in ash from thermally treated animal manure in comparison to other manure based materials and commercial fertilizer

    DEFF Research Database (Denmark)

    Kuligowski, Ksawery; Poulsen, Tjalfe Gorm; Rubæk, Gitte Holton

    2010-01-01

    ), thermally gasified SS (GAs), thermally gasified poultry manure (GAp), crushed triple super phosphate (TSP) and disodium phosphate (DSP) was used as reference P fertilizer. For application of 20 kg P ha-1 mineral P fertilizer replacement value (RV) in the second year in the sandy soil was 76% and 99% for GA...... on both soils in the second year, and there was no detectable residual effect of the treatments on grass yield and P uptake. In conclusion, untreated ash and solid manures used in this study were not suitable as starter P fertilizer, but could be used to maintain the level of available P in soil......Phosphorus (P) is an essential nutrient and a limited resource, yet excess P is applied to agricultural land and can cause environmental problems in areas with intensive animal farming. In this study, the fertilizing effects of P in several animal manure-based products (including thermal treatment...

  11. Improving greater trochanteric reattachment with a novel cable plate system.

    Science.gov (United States)

    Baril, Yannick; Bourgeois, Yan; Brailovski, Vladimir; Duke, Kajsa; Laflamme, G Yves; Petit, Yvan

    2013-03-01

    Cable-grip systems are commonly used for greater trochanteric reattachment because they have provided the best fixation performance to date, even though they have a rather high complication rate. A novel reattachment system is proposed with the aim of improving fixation stability. It consists of a Y-shaped fixation plate combined with locking screws and superelastic cables to reduce cable loosening and limit greater trochanter movement. The novel system is compared with a commercially available reattachment system in terms of greater trochanter movement and cable tensions under different greater trochanteric abductor application angles. A factorial design of experiments was used including four independent variables: plate system, cable type, abductor application angle, and femur model. The test procedure included 50 cycles of simultaneous application of an abductor force on the greater trochanter and a hip force on the femoral head. The novel plate reduces the movements of a greater trochanter fragment within a single loading cycle up to 26%. Permanent degradation of the fixation (accumulated movement based on 50-cycle testing) is reduced up to 46%. The use of superelastic cables reduces tension loosening up to 24%. However this last improvement did not result in a significant reduction of the grater trochanter movement. The novel plate and cables present advantages over the commercially available greater trochanter reattachment system. The plate reduces movements generated by the hip abductor. The superelastic cables reduce cable loosening during cycling. Both of these positive effects could decrease the risks related to grater trochanter non-union. Copyright © 2012 IPEM. Published by Elsevier Ltd. All rights reserved.

  12. In vitro gentamicin release from commercially available calcium-phosphate bone substitutes influence of carrier type on duration of the release profile

    Directory of Open Access Journals (Sweden)

    Bronckers Antonius LJJ

    2006-02-01

    Full Text Available Abstract Background Polymethyl-methacrylate (PMMA beads releasing antibiotics are used extensively to treat osteomyelitis, but require surgical removal afterwards because they do not degrade. Methods As an alternative option, this report compares the in vitro gentamicin release profile from clinically used, biodegradable carrier-materials: six injectable cements and six granule-types. Cement cylinders and coated granules containing 3% gentamicin were submerged in dH2O and placed in a 48-sample parallel drug-release system. At regular intervals (30, 90, 180 min. and then every 24 h, for 21 days, the release fluid was exchanged and the gentamicin concentration was measured. The activity of released gentamicin was tested on Staphylococcus aureus. Results All combinations showed initial burst-release of active gentamicin, two cements had continuous-release (17 days. The relative release of all cements (36–85% and granules (30–62% was higher than previously reported for injectable PMMA-cements (up to 17% and comparable to other biodegradable carriers. From the cements residual gentamicin could be extracted, whereas the granules released all gentamicin that had adhered to the surface. Conclusion The high release achieved shows great promise for clinical application of these biodegradable drug-carriers. Using the appropriate combination, the required release profile (burst or sustained may be achieved.

  13. The postprandial glucose response to some varieties of commercially available gluten-free pasta: a comparison between healthy and celiac subjects.

    Science.gov (United States)

    Bacchetti, T; Saturni, L; Turco, I; Ferretti, G

    2014-11-01

    The objective of the present paper is to evaluate the post-prandial response to some varieties of gluten free (GF) pasta that are commonly consumed in Italy. The glycaemic responses were compared with a glucose standard in healthy subjects and gluten-free diet celiac subjects. Subjects were served portions of the test foods and a standard food (glucose), on separate occasions, each containing 50 g available carbohydrates. Capillary blood glucose was measured from finger-prick samples in fasted subjects and at 15, 30, 45, 60, 90 and 120 minutes after the consumption of each test food. For each type of pasta, the glycaemic index (GI) was calculated by expressing the incremental area under the blood glucose curve as a percentage of each subject's average incremental area under the blood glucose curve (AUC) for the standard food. Gluten free pasta exhibited a range of GI values from 46 to 66. The glycaemic load (GL) and glycaemic profile (GP) were also calculated. A higher GI value was observed in pasta containing rice flour as the main ingredient. Lower values were observed in pasta obtained using corn or a mixture of corn and rice flour as the main ingredients. The results were confirmed in celiac subjects. The information presented in this paper may be useful in helping celiac people to select low-GI pasta.

  14. The effects of a commercially available botanical supplement on strength, body composition, power output, and hormonal profiles in resistance-trained males

    Directory of Open Access Journals (Sweden)

    Kreider Richard

    2010-10-01

    Full Text Available Abstract Background Fenugreek (Trigonella foenum-graecum is a leguminous, annual plant originating in India and North Africa. In recent years Fenugreek has been touted as an ergogenic aid. The purpose of this study was to evaluate the effects of Fenugreek supplementation on strength and body composition. Methods 49 Resistance trained men were matched according to body weight and randomly assigned to ingest in a double blind manner capsules containing 500 mg of a placebo (N = 23, 20 ± 1.9 years, 178 ± 6.3 cm, 85 ± 12.7 kg, 17 ± 5.6 %BF or Fenugreek (N = 26, 21 ± 2.8 years, 178 ± 6 cm, 90 ± 18.2 kg, 19.3 ± 8.4 %BF. Subjects participated in a supervised 4-day per week periodized resistance-training program split into two upper and two lower extremity workouts per week for a total of 8-weeks. At 0, 4, and 8-weeks, subjects underwent hydrodensiometery body composition, 1-RM strength, muscle endurance, and anaerobic capacity testing. Data were analyzed using repeated measures ANOVA and are presented as mean ± SD changes from baseline after 60-days. Results No significant differences (p > 0.05 between groups were noted for training volume. Significant group × time interaction effects were observed among groups in changes in body fat (FEN: -2.3 ± 1.4%BF; PL: -0.39 ± 1.6 %BF, p 0.05. Conclusion It is concluded that 500 mg of this proprietary Fenugreek extraction had a significant impact on both upper- and lower-body strength and body composition in comparison to placebo in a double blind controlled trial. These changes were obtained with no clinical side effects.

  15. Commercially available gluten-free pastas elevate postprandial glycemia in comparison to conventional wheat pasta in healthy adults: a double-blind randomized crossover trial.

    Science.gov (United States)

    Johnston, C S; Snyder, D; Smith, C

    2017-09-20

    Given the popularity of gluten-free diets, research regarding the health implications of gluten-free (GF) products is necessary. This study compared the postprandial glycemic responses to three GF pastas commonly available in the U.S. market to that of wheat pasta in healthy adults. Thirteen healthy non-smoking men and women from a university campus population were enrolled in this randomized 4 × 4 block crossover study and completed all four treatments. Participants followed a standardized diet and activity protocol the day prior to testing, and one week separated testing periods. The test meal (a macaroni and cheese dish prepared with conventional wheat pasta or with GF pasta composed of either brown rice, rice and corn, or corn and quinoa flours) was consumed under observation, and blood was sampled in the fasted state and at one-half hour intervals for the first 2 hours following meal ingestion. A significant pasta × time interaction was observed for the incremental postprandial glycemia curves (p = 0.036, repeated measures ANOVA; effect size [partial eta squared], 0.943). Post-hoc analysis revealed a significant difference for the 30-minute postprandial blood glucose concentrations: the plasma glucose concentration was 57% higher for the GF rice and corn pasta compared to traditional wheat pasta (p = 0.011). Since postprandial glycemia was higher for GF pasta composed of rice and corn flours compared to wheat pasta, more research is needed to understand how the substitute ingredients for GF pastas impact health parameters and disease risk.

  16. Gentamicin release from commercially-available gentamicin-loaded PMMA bone cements in a prosthesis-related interfacial gap model and their antibacterial efficacy

    Directory of Open Access Journals (Sweden)

    van der Mei Henny C

    2010-11-01

    Full Text Available Abstract Background Around about 1970, a gentamicin-loaded poly (methylmethacrylate (PMMA bone cement brand (Refobacin Palacos R was introduced to control infection in joint arthroplasties. In 2005, this brand was replaced by two gentamicin-loaded follow-up brands, Refobacin Bone Cement R and Palacos R + G. In addition, another gentamicin-loaded cement brand, SmartSet GHV, was introduced in Europe in 2003. In the present study, we investigated differences in gentamicin release and the antibacterial efficacy of the eluent between these four cement brands. Methods 200 μm-wide gaps were made in samples of each cement and filled with buffer in order to measure the gentamicin release. Release kinetics were related to bone cement powder particle characteristics and wettabilities of the cement surfaces. Gaps were also inoculated with bacteria isolated from infected prostheses for 24 h and their survival determined. Gentamicin release and bacterial survival were statistically analysed using the Student's t-test. Results All three Palacos variants showed equal burst releases but each of the successor Palacos cements showed significantly higher sustained releases. SmartSet GHV showed a significantly higher burst release, while its sustained release was comparable with original Palacos. A gentamicin-sensitive bacterium did not survive in the high gentamicin concentrations in the interfacial gaps, while a gentamicin-resistant strain did, regardless of the type of cement used. Survival was independent of the level of burst release by the bone cement. Conclusions Although marketed as the original gentamicin-loaded Palacos cement, orthopaedic surgeons should be aware that the successor cements do not appear to have the same release characteristics as the original one. Overall, high gentamicin concentrations were reached inside our prosthesis-related interfacial gap model. These concentrations may be expected to effectively decontaminate the prosthesis

  17. Performance of next-generation sequencing on small tumor specimens and/or low tumor content samples using a commercially available platform.

    Directory of Open Access Journals (Sweden)

    Scott Morris

    Full Text Available Next generation sequencing tests (NGS are usually performed on relatively small core biopsy or fine needle aspiration (FNA samples. Data is limited on what amount of tumor by volume or minimum number of FNA passes are needed to yield sufficient material for running NGS. We sought to identify the amount of tumor for running the PCDx NGS platform.2,723 consecutive tumor tissues of all cancer types were queried and reviewed for inclusion. Information on tumor volume, success of performing NGS, and results of NGS were compiled. Assessment of sequence analysis, mutation calling and sensitivity, quality control, drug associations, and data aggregation and analysis were performed.6.4% of samples were rejected from all testing due to insufficient tumor quantity. The number of genes with insufficient sensitivity make definitive mutation calls increased as the percentage of tumor decreased, reaching statistical significance below 5% tumor content. The number of drug associations also decreased with a lower percentage of tumor, but this difference only became significant between 1-3%. The number of drug associations did decrease with smaller tissue size as expected. Neither specimen size or percentage of tumor affected the ability to pass mRNA quality control. A tumor area of 10 mm2 provides a good margin of error for specimens to yield adequate drug association results.Specimen suitability remains a major obstacle to clinical NGS testing. We determined that PCR-based library creation methods allow the use of smaller specimens, and those with a lower percentage of tumor cells to be run on the PCDx NGS platform.

  18. Quantity of ethanol absorption after excessive hand disinfection using three commercially available hand rubs is minimal and below toxic levels for humans

    Directory of Open Access Journals (Sweden)

    Toma Cyril D

    2007-10-01

    Full Text Available Abstract Background Despite the increasing promotion of alcohol-based hand rubs and the worldwide use of ethanol-based hand rubs in hospitals only few studies have specifically addressed the issue of ethanol absorption when repeatedly applied to human skin. The aim of this study was to assess if ethanol absorption occurs during hygienic and surgical hand disinfection using three different alcohol-based hand-rubs, and to quantify absorption levels in humans. Methods Twelve volunteers applied three hand-rubs containing 95% (hand-rub A, 85% (hand-rub B and 55% ethanol (hand-rub C; all w/w. For hygienic hand disinfection, 4 mL were applied 20 times for 30 s, with 1 minute break between applications. For surgical hand disinfection, 20 mL of each hand rub was applied to hands and arms up to the level of the elbow 10 times for 3 minutes, with a break of 5 minutes between applications. Blood concentrations of ethanol and acetaldehyde were determined immediately prior and up to 90 minutes after application using head space gas chromatography. Results The median of absorbed ethanol after hygienic hand disinfection was 1365 mg (A, 630 mg (B, and 358 mg (C. The proportion of absorbed ethanol was 2.3% (A, 1.1% (B, and 0.9% (C. After surgical hand disinfection, the median of absorbed ethanol was 1067 mg (A, 1542 mg (B, and 477 mg (C. The proportion of absorbed ethanol was 0.7% (A, 1.1% (B, and 0.5% (C. The highest median acetaldehyde concentration after 20 hygienic hand disinfections was 0.57 mg/L (hand-rub C, after 30 min, after 10 surgical hand disinfections 3.99 mg/L (hand-rub A, after 20 minutes. Conclusion The overall dermal and pulmonary absorption of ethanol was below toxic levels in humans and allows the conclusion that the use of the evaluated ethanol-based hand-rubs is safe.

  19. A comparative study to evaluate the discrepancy in condylar guidance values between two commercially available arcon and non-arcon articulators: A clinical study

    Directory of Open Access Journals (Sweden)

    Mukesh Kumar Goyal

    2011-01-01

    Full Text Available Aim: The purpose of this study was comparative evaluation of sagittal condylar values of arcon and non-arcon articulators with cephalometric readings and to determine the amount of discrepancy in sagittal condylar guidance values between arcon and non-arcon articulators using same protrusive record. Materials and Methods: Twenty subjects in the age group of 19-35 years, free from temporomandibular joint dysfunction, and occlusal disharmony, with healthy dentition participated in the study. Hanau H2 (non-arcon type and Hanau Wide-Vue (arcon type articulators were programmed for sagittal condylar guidance values using the same protrusive record made in polysiloxane bite registration material with edge to edge degree of protrusion. The resultant values for both the articulators on either side were compared with values obtained from tracing of digital lateral cephalogram using Kodak Dental imaging Window software 6.6.3.0-C program. The tabulated data were subjected to statistical analysis, ANOVA (Fishers ′F′ test for group comparison, Tukey′s HSD test for inter-comparison, student′s unpaired ′t′ test for intra-group comparison, and level of significance (P was calculated using the same. Results: The mean sagittal condylar guidance values of the three different groups were found to be very highly significant (P=0.001 and highly significant (P=0.002 on the right and left sides respectively. There was a very highly significant difference (P=0.001 and highly significant difference (P=0.003 between the arcon and non-arcon group on the right and left side respectively. No significant difference was found between the arcon and cephalometric group (P=0.284 right, P=0.853 left and a statistically significant difference was found between the non-arcon and cephalometric group (P=0.049 right, P=0.015 left. On intragroup comparison there was no statistically significant difference in sagittal condylar values on the right and left sides. Conclusion

  20. Criterion-Validity of Commercially Available Physical Activity Tracker to Estimate Step Count, Covered Distance and Energy Expenditure during Sports Conditions

    Directory of Open Access Journals (Sweden)

    Yvonne Wahl

    2017-09-01

    Full Text Available Background: In the past years, there was an increasing development of physical activity tracker (Wearables. For recreational people, testing of these devices under walking or light jogging conditions might be sufficient. For (elite athletes, however, scientific trustworthiness needs to be given for a broad spectrum of velocities or even fast changes in velocities reflecting the demands of the sport. Therefore, the aim was to evaluate the validity of eleven Wearables for monitoring step count, covered distance and energy expenditure (EE under laboratory conditions with different constant and varying velocities.Methods: Twenty healthy sport students (10 men, 10 women performed a running protocol consisting of four 5 min stages of different constant velocities (4.3; 7.2; 10.1; 13.0 km·h−1, a 5 min period of intermittent velocity, and a 2.4 km outdoor run (10.1 km·h−1 while wearing eleven different Wearables (Bodymedia Sensewear, Beurer AS 80, Polar Loop, Garmin Vivofit, Garmin Vivosmart, Garmin Vivoactive, Garmin Forerunner 920XT, Fitbit Charge, Fitbit Charge HR, Xaomi MiBand, Withings Pulse Ox. Step count, covered distance, and EE were evaluated by comparing each Wearable with a criterion method (Optogait system and manual counting for step count, treadmill for covered distance and indirect calorimetry for EE.Results: All Wearables, except Bodymedia Sensewear, Polar Loop, and Beurer AS80, revealed good validity (small MAPE, good ICC for all constant and varying velocities for monitoring step count. For covered distance, all Wearables showed a very low ICC (<0.1 and high MAPE (up to 50%, revealing no good validity. The measurement of EE was acceptable for the Garmin, Fitbit and Withings Wearables (small to moderate MAPE, while Bodymedia Sensewear, Polar Loop, and Beurer AS80 showed a high MAPE up to 56% for all test conditions.Conclusion: In our study, most Wearables provide an acceptable level of validity for step counts at different

  1. Commercial Banks

    Directory of Open Access Journals (Sweden)

    Abbas Asosheh

    2009-09-01

    Full Text Available Information systems outsourcing issues has been attracted in recent years because many information systems projects in organizations are done in this case. On the other hand, failure rate of this kind of projects is also high. The aim of this article is to find success factors in risk management of information systems outsourcing in commercial banks using these factors leads to increase the success rate of risk management of information systems outsourcing projects. Research methods in the present article based on purpose are applied and descriptive- survey. In addition, research tool is questionnaire which was used among commercial bank experts. For this purpose, First information systems outsourcing risks were identified and then ranked. In the next step, the information systems outsourcing reasons were surveyed and the most important reasons were identified. Then the risks which have not any relationship with the most important reasons were removed and success factors in managing residual risks were extracted.

  2. Greater-confinement disposal

    International Nuclear Information System (INIS)

    Trevorrow, L.E.; Schubert, J.P.

    1989-01-01

    Greater-confinement disposal (GCD) is a general term for low-level waste (LLW) disposal technologies that employ natural and/or engineered barriers and provide a degree of confinement greater than that of shallow-land burial (SLB) but possibly less than that of a geologic repository. Thus GCD is associated with lower risk/hazard ratios than SLB. Although any number of disposal technologies might satisfy the definition of GCD, eight have been selected for consideration in this discussion. These technologies include: (1) earth-covered tumuli, (2) concrete structures, both above and below grade, (3) deep trenches, (4) augered shafts, (5) rock cavities, (6) abandoned mines, (7) high-integrity containers, and (8) hydrofracture. Each of these technologies employ several operations that are mature,however, some are at more advanced stages of development and demonstration than others. Each is defined and further described by information on design, advantages and disadvantages, special equipment requirements, and characteristic operations such as construction, waste emplacement, and closure

  3. Greater oil investment opportunities

    International Nuclear Information System (INIS)

    Arenas, Ismael Enrique

    1997-01-01

    Geologically speaking, Colombia is a very attractive country for the world oil community. According to this philosophy new and important steps are being taken to reinforce the oil sector: Expansion of the exploratory frontier by including a larger number of sedimentary areas, and the adoption of innovative contracting instruments. Colombia has to offer, Greater economic incentives for the exploration of new areas to expand the exploratory frontier, stimulation of exploration in areas with prospectivity for small fields. Companies may offer Ecopetrol a participation in production over and above royalties, without it's participating in the investments and costs of these fields, more favorable conditions for natural gas seeking projects, in comparison with those governing the terms for oil

  4. FLUORIDE LEVELS IN COMMERCIALLY AVAILABLE RICE IN ...

    African Journals Online (AJOL)

    Preferred Customer

    2013-05-05

    May 5, 2013 ... Rice is one of the commonly consumed cereals for more than half of the ... also used as flour, for making rice wine, as ingredient for beer and liquor, ... Fluoride is a necessary element to human health, and a moderate amount of fluoride intake ... For Ethiopian red rice (ERR) Fogera was selected to collect.

  5. LEVELS OF METALS IN COMMERCIALLY AVAILABLE ETHIOPIAN ...

    African Journals Online (AJOL)

    Preferred Customer

    Tea, one of the most popular beverages in the world, is an infusion of the leaves of .... the local market of Ethiopia and (ii) the three tea brands represent the three different tea ..... Kumar, A.; Nair, A.G.C.; Reddy, A.V.R.; Garg, A.N. Food Chem.

  6. Microbiological Assessment of Commercially Available Quinine ...

    African Journals Online (AJOL)

    Erah

    Key words: Microbiological quality, quinine syrups, water for injection, pyrogen test. Received: 12 February ... pharmaceutical industry is indispensable, especially in ... Production of WFI or any other pharmaceutical products .... culture media.

  7. Inter comparison of two commercially available SODARS

    DEFF Research Database (Denmark)

    Ejsing Jørgensen, Hans; Antoniou, I.

    2002-01-01

    In the present work two SODARs of the phased array type are compared indirectly using the top anemometer readings from the Risoe 125m instrumented meteorology mast. The two SODARs are the AeroVironment 4000 and the Metek DSDPA.90-24.......In the present work two SODARs of the phased array type are compared indirectly using the top anemometer readings from the Risoe 125m instrumented meteorology mast. The two SODARs are the AeroVironment 4000 and the Metek DSDPA.90-24....

  8. Characteristics and availability of commercially important woods

    Science.gov (United States)

    Regis B. Miller

    1999-01-01

    Throughout history, the unique characteristics and comparative abundance of wood have made it a natural material for homes and other structures, furniture, tools, vehicles, and decorative objects. Today, for the same reasons, wood is prized for a multitude of uses. All wood is composed of cellulose, lignin, hemicelluloses, and minor amounts (5% to 10%) of extraneous...

  9. Laboratory Assessment of Commercially Available Ultrasonic Rangefinders

    Science.gov (United States)

    2015-11-01

    HRLV-MaxSonar®-EZ4™, MB1220 XL-MaxSonar®- EZ2™, MB1240 XL-MaxSonar®-EZ4™, or MB1261 XL-MaxSonar®-EZL1™) and an Arduino Mega 2560* board to interface...measurements. The Arduino board and ultrasonic rangefinder were connected to the computer via universal serial bus (USB) cable, which acted as both...7.7593 x 10-92 4.3606 x 10-94 3.2443 x 10-68 8.2303 x 10-72 2.5376 x 10-26 19 Appendix B. Manufacturer’s list. Arduino LLC https

  10. Commercial lumber

    Science.gov (United States)

    Kent A. McDonald; David E. Kretschmann

    1999-01-01

    In a broad sense, commercial lumber is any lumber that is bought or sold in the normal channels of commerce. Commercial lumber may be found in a variety of forms, species, and types, and in various commercial establishments, both wholesale and retail. Most commercial lumber is graded by standardized rules that make purchasing more or less uniform throughout the country...

  11. Selection of Common Bean Lines, Recombinant Inbred Lines and Commercial Genotypes Tolerant to Low Phosphorus Availability in an Acrisol Soil on the Basis of Root Traits and Grain Yield

    Energy Technology Data Exchange (ETDEWEB)

    Garcia, A.; Gomez, L. A.; Morales, A. [Instituto de Suelos, MINAG (Cuba); others, and

    2013-11-15

    Common bean (Phaseolus vulgaris L.) is the most important food legume for human consumption worldwide and especially in Latin America and Africa, but low soil phosphorus (P) availability limits grain production in these areas. For these reason eighty five recombinant inbred lines (RILs) of BAT 477 x DOR 364 and twenty commercial bean genotypes were sown in plots in an Acrisol soil with low P availability to evaluate nine root traits and grain yield. The study was carried out in Pinar del Rio province in Cuba between November 2006 and February 2009. The plots received basal fertilization (N and K) and P fertilization between 15 and 90 kg P{sub 2}O{sub 5} ha{sup -1}. Ten plants were sampled from each plot at R{sub 6} pod fill to evaluate root traits and shoot biomass, and at R{sub 9} physiological maturity to estimate grain yield. The 85 RILs showed great variability for root traits, grain yield and P stress tolerance calculated as relative grain yield. The commercial bean lines also showed large diversity in yield parameters. Principal Component Analysis showed that there were high and significant correlations between root traits (basal root number, primary root depth, adventitious root length and adventitious root number) and grain yield parameters (grain yield at 15 P level and relative grain yields). Adventitious root traits showed the greatest correlation with yield under low P. Promising RILs included 75.1.1, 60.1.1, 38.1.1, 14.1.1 and 38.1.1 and promising commercial bean lines included ICA Pijao, BAT 482, ICA 23, BAT 24 and BAT 832. (author)

  12. Using a commercially available DNA extraction kit to obtain high quality human genomic DNA suitable for PCR and genotyping from 11-year-old saliva saturated cotton spit wads

    Directory of Open Access Journals (Sweden)

    Hudziak James J

    2008-12-01

    Full Text Available Abstract Background We sought to describe the integrity of human genomic DNA extracted from saliva saturated cotton spit wads stored at -20°C for approximately 11 years. 783 spit wad samples were collected from an ADHD sample population (Vermont Family Study during 1996–2000. Human genomic DNA was extracted from the spit wads using a commercially available kit; QIAamp DNA Blood Midi Kit (Qiagen, Inc., Valencia, CA. with a few modifications. Results The resulting DNA yield was more than adequate for genetic analysis and ranged from approximately 1 μg to a total of 80 μg (mean 17.3 μgs ± 11.9 μgs. A260/A280 ratios for the human genomic DNA extracted from the spit wads was consistently within the generally acceptable values of 1.7–2.0, with the lowest purity being 1.70, and a mean value of 1.937 ± 0.226 for the 783 samples. The DNA also was suitable for PCR reactions as evidenced by the amplification of the serotonin-transporter-linked polymorphic region, 5HTTLPR. 5HTTLPR is a functional polymorphism in the promoter region of the serotonin transporter gene (HTT, SLC6A4, or SERT, consisting of two intensively studied alleles. 770 of the 783 samples (98.3% produced fragments after PCR of the expected size with primers specific for 5HTTLPR. Conclusion High quality and abundant genomic DNA can be successfully retrieved from saliva saturated cotton spit wads using the commercially available kit, QIAamp DNA Blood Midi Kit from Qiagen, Inc. Furthermore, the DNA can be extracted in less than 3 hours and multiple samples can be processed simultaneously thus reducing processing time.

  13. Comparative evaluation of three automated systems for DNA extraction in conjunction with three commercially available real-time PCR assays for quantitation of plasma Cytomegalovirus DNAemia in allogeneic stem cell transplant recipients.

    Science.gov (United States)

    Bravo, Dayana; Clari, María Ángeles; Costa, Elisa; Muñoz-Cobo, Beatriz; Solano, Carlos; José Remigia, María; Navarro, David

    2011-08-01

    Limited data are available on the performance of different automated extraction platforms and commercially available quantitative real-time PCR (QRT-PCR) methods for the quantitation of cytomegalovirus (CMV) DNA in plasma. We compared the performance characteristics of the Abbott mSample preparation system DNA kit on the m24 SP instrument (Abbott), the High Pure viral nucleic acid kit on the COBAS AmpliPrep system (Roche), and the EZ1 Virus 2.0 kit on the BioRobot EZ1 extraction platform (Qiagen) coupled with the Abbott CMV PCR kit, the LightCycler CMV Quant kit (Roche), and the Q-CMV complete kit (Nanogen), for both plasma specimens from allogeneic stem cell transplant (Allo-SCT) recipients (n = 42) and the OptiQuant CMV DNA panel (AcroMetrix). The EZ1 system displayed the highest extraction efficiency over a wide range of CMV plasma DNA loads, followed by the m24 and the AmpliPrep methods. The Nanogen PCR assay yielded higher mean CMV plasma DNA values than the Abbott and the Roche PCR assays, regardless of the platform used for DNA extraction. Overall, the effects of the extraction method and the QRT-PCR used on CMV plasma DNA load measurements were less pronounced for specimens with high CMV DNA content (>10,000 copies/ml). The performance characteristics of the extraction methods and QRT-PCR assays evaluated herein for clinical samples were extensible at cell-based standards from AcroMetrix. In conclusion, different automated systems are not equally efficient for CMV DNA extraction from plasma specimens, and the plasma CMV DNA loads measured by commercially available QRT-PCRs can differ significantly. The above findings should be taken into consideration for the establishment of cutoff values for the initiation or cessation of preemptive antiviral therapies and for the interpretation of data from clinical studies in the Allo-SCT setting.

  14. CHARACTERIZATION OF COMMERCIALLY AVAILABLE ALKALI RESISTANT GLASS FIBER FOR CONCRETE REINFORCEMENT AND CHEMICAL DURABILITY COMPARISON WITH SrO-Mn2O3-Fe2O3-MgO-ZrO2-SiO2 (SMFMZS SYSTEM GLASSES

    Directory of Open Access Journals (Sweden)

    Göktuğ GÜNKAYA

    2012-12-01

    Full Text Available According to the relevant literature, the utilization of different kind of glass fibers in concrete introduces positive effect on the mechanical behavior, especially toughness. There are many glassfibers available to reinforce concretes. Glass fiber composition is so important because it may change the properties such as strength, elastic modulus and alkali resistance. Its most important property to be used in concrete is the alkali resistance. Some glasses of SrO–MgO–ZrO2–SiO2 (SMZS quaternary system, such as 26SrO, 20MgO, 14ZrO2, 40SiO2 (Zrn glass, have been found to be highly alkali resistant thanks to their high ZrO2 and MgO contents. Previous researches on these glasses with MnO and/or Fe2O3 partially replacing SrO have been made with the aim of improving the chemical resistance and decreasing the production cost.The main target of the present study, first of all, was to characterize commercially available alkali resistant glass fiber for concrete reinforcement and then to compare its alkali durability with those of the SrO-Mn2O3-Fe2O3-MgO-ZrO2-SiO2 (SMFMZS system glasses. For such purposes, XRF, Tg-DTA, alkali resistance tests and SEM analysis conducted with EDX were employed. According tothe alkali endurance test results it was revealed that some of the SMFMZS system glass powders are 10 times resistant to alkali environments than the commercial glass fibers used in this study.Therefore, they can be considered as alternative filling materials on the evolution of chemically resistant concrete structures.

  15. Effects of 28 days of resistance exercise and consuming a commercially available pre-workout supplement, NO-Shotgun®, on body composition, muscle strength and mass, markers of satellite cell activation, and clinical safety markers in males

    Directory of Open Access Journals (Sweden)

    Leutholtz Brian

    2009-08-01

    Full Text Available Abstract Purpose This study determined the effects of 28 days of heavy resistance exercise combined with the nutritional supplement, NO-Shotgun®, on body composition, muscle strength and mass, markers of satellite cell activation, and clinical safety markers. Methods Eighteen non-resistance-trained males participated in a resistance training program (3 × 10-RM 4 times/wk for 28 days while also ingesting 27 g/day of placebo (PL or NO-Shotgun® (NO 30 min prior to exercise. Data were analyzed with separate 2 × 2 ANOVA and t-tests (p Results Total body mass was increased in both groups (p = 0.001, but without any significant increases in total body water (p = 0.77. No significant changes occurred with fat mass (p = 0.62; however fat-free mass did increase with training (p = 0.001, and NO was significantly greater than PL (p = 0.001. Bench press strength for NO was significantly greater than PL (p = 0.003. Myofibrillar protein increased with training (p = 0.001, with NO being significantly greater than PL (p = 0.019. Serum IGF-1 (p = 0.046 and HGF (p = 0.06 were significantly increased with training and for NO HGF was greater than PL (p = 0.002. Muscle phosphorylated c-met was increased with training for both groups (p = 0.019. Total DNA was increased in both groups (p = 0.006, while NO was significantly greater than PL (p = 0.038. For DNA/protein, PL was decreased and NO was not changed (p = 0.014. All of the myogenic regulatory factors were increased with training; however, NO was shown to be significantly greater than PL for Myo-D (p = 0.008 and MRF-4 (p = 0.022. No significant differences were located for any of the whole blood and serum clinical chemistry markers (p > 0.05. Conclusion When combined with heavy resistance training for 28 days, NO-Shotgun® is not associated with any negative side effects, nor does it abnormally impact any of the clinical chemistry markers. Rather, NO-Shotgun® effectively increases muscle strength and mass

  16. Wean-to-finish feeder space availability effects on nursery and finishing pig performance and total tract digestibility in a commercial setting when feeding dried distillers grains with solubles.

    Science.gov (United States)

    Weber, E K; Stalder, K J; Patience, J F

    2015-04-01

    The study objectives were to determine nursery phase feeder space allowance effects on pig performance when double stocked and, second, to determine feeder space allowance and dried distillers grains with solubles (DDGS) inclusion level effects on pig performance and nutrient digestibility during the growing-finishing phase. This study was performed on the same group of pigs within a commercial wean-finish system. For the nursery phase, a completely randomized design was used to compare 3 feeder space allowance treatments (2.1, 2.5, and 2.9 cm/pig). A total of 3,720 pigs were randomly allotted to same-sex pens (10 feeders/treatment) housing 62 pigs/pen. Thirty 7-hole, double-sided feeders were utilized in the study. Differing linear feeder space treatments were established by blocking off sections for the nursery and grow-finish portions of this experiment. All pigs were provided equal floor space (0.26 m2/pig). In the grow-finish phase, a total of 1,860 pigs (n = 60 pens) were utilized in a 2 × 3 factorial design with 3 feeder space allowances (4.1, 4.9, or 5.7 cm/pig) and 2 dietary DDGS treatments (30% [D30] or 60% [D60]). Fecal and diet samples were collected and analyzed to estimate apparent total tract digestibility percentage (ATTD %). In the nursery portion of the trial, there was no feeder space treatment effect on ADG, ADFI, or feed efficiency (P > 0.10) from weaning to d 56 postweaning or during any weigh period. In the grow-finish portion of the trial, feeder space allowance and DDGS inclusion level did not affect ADG, ADFI, or feed efficiency (P > 0.05) from d 57 postweaning to market. Pigs fed the D30 diet had greater HCW, percent yield, and loin depth than those on the D60 diet (P feeder space allowance did not impact pig performance during the nursery or grow-finish production phases. Inclusion of DDGS at higher levels will decrease ADFI but not ADG or efficiency when isocaloric diets are fed. The inclusion level of DDGS does impact HCW and percent

  17. Sensitive and specific detection of potentially allergenic almond (Prunus dulcis) in complex food matrices by Taqman real-time polymerase chain reaction in comparison to commercially available protein-based enzyme-linked immunosorbent assay

    Energy Technology Data Exchange (ETDEWEB)

    Roeder, Martin; Vieths, Stefan [Division of Allergology, Paul-Ehrlich-Institut, Paul-Ehrlich-Strasse 51-59, 63225 Langen (Germany); Holzhauser, Thomas, E-mail: holth@pei.de [Division of Allergology, Paul-Ehrlich-Institut, Paul-Ehrlich-Strasse 51-59, 63225 Langen (Germany)

    2011-01-24

    Currently, causative immunotherapies are lacking in food allergy. The only option to prevent allergic reactions in susceptible individuals is to strictly avoid the offending food. Thus, reliable labelling of allergenic constituents is of major importance, but can only be achieved if appropriate specific and sensitive detection techniques for foods with allergenic potential are available. Almond is an allergenic food that requires mandatory labelling on prepackaged foods and belongs to the genus Prunus. Species of this genus are phylogenetically closely related. We observed commercially available almond specific ELISA being highly cross-reactive with other foods of the Prunoideae family, resulting in a false-positive detection of up to 500,000 mg kg{sup -1} almond. Previously published PCR methods were reported to be cross-reactive with false positive results >1200 mg kg{sup -1}. We describe the development of a novel almond specific real-time PCR, based on mutated mismatch primers and sequence specific Taqman probe detection, in comparison with two quantitative commercially available ELISA. PCR sensitivity was investigated with chocolate, chocolate coating and cookies spiked between 5 and 100,000 mg kg{sup -1} almond. In all matrices almond was reproducibly detected by real-time PCR at the lowest spike level of 5 mg kg{sup -1}. Further, between 100 and 100,000 mg kg{sup -1} spiked almond, the method featured good correlation between quantified copy numbers and the amount of spiked almond. Within this range a similar relation between detectable signal and amount of almond was observed for both PCR and ELISA. In contrast to ELISA the Taqman real-time PCR method was highly specific in 59 food items with negligible cross-reactivity for a very limited number of Prunoideae foods. The real-time PCR analysis of 24 retail samples was in concordance with ELISA results: 21% (n = 5) contained undeclared almond. This is the first completely disclosed real-time PCR method for a

  18. Sensitive and specific detection of potentially allergenic almond (Prunus dulcis) in complex food matrices by Taqman(®) real-time polymerase chain reaction in comparison to commercially available protein-based enzyme-linked immunosorbent assay.

    Science.gov (United States)

    Röder, Martin; Vieths, Stefan; Holzhauser, Thomas

    2011-01-24

    Currently, causative immunotherapies are lacking in food allergy. The only option to prevent allergic reactions in susceptible individuals is to strictly avoid the offending food. Thus, reliable labelling of allergenic constituents is of major importance, but can only be achieved if appropriate specific and sensitive detection techniques for foods with allergenic potential are available. Almond is an allergenic food that requires mandatory labelling on prepackaged foods and belongs to the genus Prunus. Species of this genus are phylogenetically closely related. We observed commercially available almond specific ELISA being highly cross-reactive with other foods of the Prunoideae family, resulting in a false-positive detection of up to 500,000 mg kg(-1) almond. Previously published PCR methods were reported to be cross-reactive with false positive results >1200 mg kg(-1). We describe the development of a novel almond specific real-time PCR, based on mutated mismatch primers and sequence specific Taqman(®) probe detection, in comparison with two quantitative commercially available ELISA. PCR sensitivity was investigated with chocolate, chocolate coating and cookies spiked between 5 and 100,000 mg kg(-1) almond. In all matrices almond was reproducibly detected by real-time PCR at the lowest spike level of 5 mg kg(-1). Further, between 100 and 100,000 mg kg(-1) spiked almond, the method featured good correlation between quantified copy numbers and the amount of spiked almond. Within this range a similar relation between detectable signal and amount of almond was observed for both PCR and ELISA. In contrast to ELISA the Taqman(®) real-time PCR method was highly specific in 59 food items with negligible cross-reactivity for a very limited number of Prunoideae foods. The real-time PCR analysis of 24 retail samples was in concordance with ELISA results: 21% (n=5) contained undeclared almond. This is the first completely disclosed real-time PCR method for a specific and

  19. Sensitive and specific detection of potentially allergenic almond (Prunus dulcis) in complex food matrices by Taqman real-time polymerase chain reaction in comparison to commercially available protein-based enzyme-linked immunosorbent assay

    International Nuclear Information System (INIS)

    Roeder, Martin; Vieths, Stefan; Holzhauser, Thomas

    2011-01-01

    Currently, causative immunotherapies are lacking in food allergy. The only option to prevent allergic reactions in susceptible individuals is to strictly avoid the offending food. Thus, reliable labelling of allergenic constituents is of major importance, but can only be achieved if appropriate specific and sensitive detection techniques for foods with allergenic potential are available. Almond is an allergenic food that requires mandatory labelling on prepackaged foods and belongs to the genus Prunus. Species of this genus are phylogenetically closely related. We observed commercially available almond specific ELISA being highly cross-reactive with other foods of the Prunoideae family, resulting in a false-positive detection of up to 500,000 mg kg -1 almond. Previously published PCR methods were reported to be cross-reactive with false positive results >1200 mg kg -1 . We describe the development of a novel almond specific real-time PCR, based on mutated mismatch primers and sequence specific Taqman probe detection, in comparison with two quantitative commercially available ELISA. PCR sensitivity was investigated with chocolate, chocolate coating and cookies spiked between 5 and 100,000 mg kg -1 almond. In all matrices almond was reproducibly detected by real-time PCR at the lowest spike level of 5 mg kg -1 . Further, between 100 and 100,000 mg kg -1 spiked almond, the method featured good correlation between quantified copy numbers and the amount of spiked almond. Within this range a similar relation between detectable signal and amount of almond was observed for both PCR and ELISA. In contrast to ELISA the Taqman real-time PCR method was highly specific in 59 food items with negligible cross-reactivity for a very limited number of Prunoideae foods. The real-time PCR analysis of 24 retail samples was in concordance with ELISA results: 21% (n = 5) contained undeclared almond. This is the first completely disclosed real-time PCR method for a specific and

  20. Dengue Virus NS1 Protein as a Diagnostic Marker: Commercially Available ELISA and Comparison to qRT-PCR and Serological Diagnostic Assays Currently Used by the State of Florida

    Directory of Open Access Journals (Sweden)

    Jason H. Ambrose

    2017-01-01

    Full Text Available Background. The proper management of patients infected with dengue virus requires early detection. Here, real-time molecular assays have proven useful but have limitations, whereas ELISAs that detect antibodies are still favored but results are obtained too late to be of clinical value. The production of DENV NS1 peaks early during infection and its detection can combine the advantages of both diagnostic approaches. Methods. This study compared assays currently used for detecting DENV infection at the Florida Department of Health including anti-DENV IgM and IgG ELISAs as well as qRT-PCR, against a commercially available DENV NS1 ELISA. These comparisons were made among a group of 21 human sera. Results. Nine of 14 (64.3% DENV qRT-PCR+ samples were also DENV NS1+. Interestingly, the 5 NS1− samples that were qRT-PCR+ were additionally IgM− and IgG+ suggesting a nonprimary infection. Compared to qRT-PCR, the NS1 assay had a sensitivity of 64.3%, specificity 100%, PPV of 100%, and NPV of 58.3%. Conclusions. The NS1 ELISA performed as expected in known DENV qRT-PCR+ samples; however negative NS1 results for qRT-PCR+ and IgG+ sera seemingly reduced the usefulness of the NS1 ELISA for nonprimary cases. We therefore conclude that diagnosis obtained via DENV NS1 ELISA deserves further investigation.

  1. Operational technology for greater confinement disposal

    International Nuclear Information System (INIS)

    Dickman, P.T.; Vollmer, A.T.; Hunter, P.H.

    1984-12-01

    Procedures and methods for the design and operation of a greater confinement disposal facility using large-diameter boreholes are discussed. It is assumed that the facility would be located at an operating low-level waste disposal site and that only a small portion of the wastes received at the site would require greater confinement disposal. The document is organized into sections addressing: facility planning process; facility construction; waste loading and handling; radiological safety planning; operations procedures; and engineering cost studies. While primarily written for low-level waste management site operators and managers, a detailed economic assessment section is included that should assist planners in performing cost analyses. Economic assessments for both commercial and US government greater confinement disposal facilities are included. The estimated disposal costs range from $27 to $104 per cubic foot for a commercial facility and from $17 to $60 per cubic foot for a government facility. These costs are based on average site preparation, construction, and waste loading costs for both contact- and remote-handled wastes. 14 figures, 22 tables

  2. Assessing the acidity and total sugar content of four different commercially available beverages commonly consumed by children and its time-dependent effect on plaque and salivary pH

    Directory of Open Access Journals (Sweden)

    Abhishek Jha

    2015-01-01

    Full Text Available Introduction: Sugared beverages such as cola, packaged juice, are known for cariogenicity their intake leads to the immediate drop in plaque and salivary pH, which can be an etiologic factor for dental caries. Objective: The objective was to assess the endogenous acidity and total sugar content of four commercially available beverages commonly consumed by children in India and its effect on salivary and plaque pH. Materials and Methods: A crossover controlled trial was conducted. 60 randomly selected school children from school at south Bangalore, who were meeting the inclusion criteria, were asked to refrain from oral hygiene practices for 24 h till the sample collection. Children were divided into four groups and for each group test drink was given. Plaque and salivary sample were collected at the time of 2, 5, 10, 20, and 30 min and were sent for pH estimation. 7 days of washout time was given for each cross-over and 3 such cross-over was done during the study and the drinks were interchanged. Results: Sweet lassi was found to be having maximum total sugar content of and Coca-Cola had the lowest pH 5.3. Milk showed least sugar content and highest pH (6.7. Study showed a significant drop in pH after consumption of all the test drinks (P = 0. 05. Carbonated beverage, that is, Coca-Cola Showed the maximum drop of pH, followed by Pulpy orange in both the plaque as well as saliva. Coca-Cola showed the drop of plaque pH below the critical level, 5.44 (0.134. Conclusion: Sweet lassi showed the maximum inherent total sugar content, lowest inherent pH and maximum fall in plaque and salivary pH, was found with Coca-Cola.

  3. Characterization of the commercially-available fluorescent chloroquine-BODIPY conjugate, LynxTag-CQGREEN, as a marker for chloroquine resistance and uptake in a 96-well plate assay.

    Directory of Open Access Journals (Sweden)

    Cheryl C Y Loh

    Full Text Available Chloroquine was a cheap, extremely effective drug against Plasmodium falciparum until resistance arose. One approach to reversing resistance is the inhibition of chloroquine efflux from its site of action, the parasite digestive vacuole. Chloroquine accumulation studies have traditionally relied on radiolabelled chloroquine, which poses several challenges. There is a need for development of a safe and biologically relevant substitute. We report here a commercially-available green fluorescent chloroquine-BODIPY conjugate, LynxTag-CQGREEN, as a proxy for chloroquine accumulation. This compound localized to the digestive vacuole of the parasite as observed under confocal microscopy, and inhibited growth of chloroquine-sensitive strain 3D7 more extensively than in the resistant strains 7G8 and K1. Microplate reader measurements indicated suppression of LynxTag-CQGREEN efflux after pretreatment of parasites with known reversal agents. Microsomes carrying either sensitive- or resistant-type PfCRT were assayed for uptake; resistant-type PfCRT exhibited increased accumulation of LynxTag-CQGREEN, which was suppressed by pretreatment with known chemosensitizers. Eight laboratory strains and twelve clinical isolates were sequenced for PfCRT and Pgh1 haplotypes previously reported to contribute to drug resistance, and pfmdr1 copy number and chloroquine IC50s were determined. These data were compared with LynxTag-CQGREEN uptake/fluorescence by multiple linear regression to identify genetic correlates of uptake. Uptake of the compound correlated with the logIC50 of chloroquine and, more weakly, a mutation in Pgh1, F1226Y.

  4. Atividade antiviral de extratos de plantas medicinais disponíveis comercialmente frente aos herpesvírus suíno e bovino Antiviral activity of commercially available medicinal plants on suid and bovine herpesviruses

    Directory of Open Access Journals (Sweden)

    V.M. Kaziyama

    2012-01-01

    Full Text Available O presente trabalho teve como objetivo pesquisar a atividade antiviral in vitro de plantas medicinais disponíveis comercialmente sobre herpesvírus suíno (SuHV-1 e bovino (BoHV-1. As espécies adquiridas foram Mikania glomerata, Cymbopogon citratus, Equisetum arvense, Peumus boldus, Solanum paniculatum, Malva sylvestris, Piper umbellatun e Solidago microglossa. A citotoxicidade dos extratos foi avaliada na linhagem celular MDBK pelas alterações morfológicas das células e obtenção da concentração máxima não citotóxica (CMNC de cada planta. A atividade antiviral foi realizada com os extratos em suas respectivas CMNC e avaliada com base na redução do título viral e expressos em porcentagem de inibição. Os extratos aquosos de Peumus boldus e Solanum paniculatum apresentaram atividade antiviral sobre o SuHV-1 com 98% de inibição viral enquanto o de Peumus boldus inibiu apenas o BoHV-1 em 99%.This paper aims to find commercially available medicinal plants showing antiviral activity in vitro on suid and bovine herpesviruses. The following species were tested: Mikania glomerata, Cymbopogon citratus, Equisetum arvense, Peumus boldus, Solanum paniculatum, Malva sylvestris, Piper umbellatun and Solidago microglossa. The cytotoxicity was evaluated by morphological changes in cells determining the maximum not cytotoxic concentration (MNCC. The antiviral activity was evaluated by viral title reduction. The extracts from Peumus boldus and Solanum paniculatum showed antiviral activity against SuHV-1 with 98% of inhibition. The extract of Peumus boldus also showed activity against BoHV-1 with 99% of inhibition.

  5. Commercial Toilets

    Science.gov (United States)

    Whether you are looking to reduce water use in a new facility or replace old, inefficient toilets in commercial restrooms, a WaterSense labeled flushometer-valve toilet is a high-performance, water-efficient option worth considering.

  6. Space Commercialization

    Science.gov (United States)

    Martin, Gary L.

    2011-01-01

    A robust and competitive commercial space sector is vital to continued progress in space. The United States is committed to encouraging and facilitating the growth of a U.S. commercial space sector that supports U.S. needs, is globally competitive, and advances U.S. leadership in the generation of new markets and innovation-driven entrepreneurship. Energize competitive domestic industries to participate in global markets and advance the development of: satellite manufacturing; satellite-based services; space launch; terrestrial applications; and increased entrepreneurship. Purchase and use commercial space capabilities and services to the maximum practical extent Actively explore the use of inventive, nontraditional arrangements for acquiring commercial space goods and services to meet United States Government requirements, including measures such as public-private partnerships, . Refrain from conducting United States Government space activities that preclude, discourage, or compete with U.S. commercial space activities. Pursue potential opportunities for transferring routine, operational space functions to the commercial space sector where beneficial and cost-effective.

  7. Accuracy of a new patch pump based on a microelectromechanical system (MEMS) compared to other commercially available insulin pumps: results of the first in vitro and in vivo studies.

    Science.gov (United States)

    Borot, Sophie; Franc, Sylvia; Cristante, Justine; Penfornis, Alfred; Benhamou, Pierre-Yves; Guerci, Bruno; Hanaire, Hélène; Renard, Eric; Reznik, Yves; Simon, Chantal; Charpentier, Guillaume

    2014-11-01

    The JewelPUMP™ (JP) is a new patch pump based on a microelectromechanical system that operates without any plunger. The study aimed to evaluate the infusion accuracy of the JP in vitro and in vivo. For the in vitro studies, commercially available pumps meeting the ISO standard were compared to the JP: the MiniMed® Paradigm® 712 (MP), Accu-Chek® Combo (AC), OmniPod® (OP), Animas® Vibe™ (AN). Pump accuracy was measured over 24 hours using a continuous microweighing method, at 0.1 and 1 IU/h basal rates. The occlusion alarm threshold was measured after a catheter occlusion. The JP, filled with physiological serum, was then tested in 13 patients with type 1 diabetes simultaneously with their own pump for 2 days. The weight difference was used to calculate the infused insulin volume. The JP showed reduced absolute median error rate in vitro over a 15-minute observation window compared to other pumps (1 IU/h): ±1.02% (JP) vs ±1.60% (AN), ±1.66% (AC), ±2.22% (MP), and ±4.63% (OP), P pumps: 21 (19; 25) minutes vs 90 (85; 95), 58 (42; 74), and 143 (132; 218) minutes (AN, AC, MP), P pumps (-2.2 ± 5.6% vs -0.37 ± 4.0%, P = .25). The JP was found to be easier to wear than conventional pumps. The JP is more precise over a short time period, more sensitive to catheter occlusion, well accepted by patients, and consequently, of potential interest for a closed-loop insulin delivery system. © 2014 Diabetes Technology Society.

  8. Therapeutic ultrasound as a potential male contraceptive: power, frequency and temperature required to deplete rat testes of meiotic cells and epididymides of sperm determined using a commercially available system

    Directory of Open Access Journals (Sweden)

    Tsuruta James K

    2012-01-01

    Full Text Available Abstract Background Studies published in the 1970s by Mostafa S. Fahim and colleagues showed that a short treatment with ultrasound caused the depletion of germ cells and infertility. The goal of the current study was to determine if a commercially available therapeutic ultrasound generator and transducer could be used as the basis for a male contraceptive. Methods Sprague-Dawley rats were anesthetized and their testes were treated with 1 MHz or 3 MHz ultrasound while varying power, duration and temperature of treatment. Results We found that 3 MHz ultrasound delivered with 2.2 Watt per square cm power for fifteen minutes was necessary to deplete spermatocytes and spermatids from the testis and that this treatment significantly reduced epididymal sperm reserves. 3 MHz ultrasound treatment reduced total epididymal sperm count 10-fold lower than the wet-heat control and decreased motile sperm counts 1,000-fold lower than wet-heat alone. The current treatment regimen provided nominally more energy to the treatment chamber than Fahim's originally reported conditions of 1 MHz ultrasound delivered at 1 Watt per square cm for ten minutes. However, the true spatial average intensity, effective radiating area and power output of the transducers used by Fahim were not reported, making a direct comparison impossible. We found that germ cell depletion was most uniform and effective when we rotated the therapeutic transducer to mitigate non-uniformity of the beam field. The lowest sperm count was achieved when the coupling medium (3% saline was held at 37 degrees C and two consecutive 15-minute treatments of 3 MHz ultrasound at 2.2 Watt per square cm were separated by 2 days. Conclusions The non-invasive nature of ultrasound and its efficacy in reducing sperm count make therapeutic ultrasound a promising candidate for a male contraceptive. However, further studies must be conducted to confirm its efficacy in providing a contraceptive effect, to test the

  9. Autoantibodies to the Rpp25 component of the Th/To complex are the most common antibodies in patients with systemic sclerosis without antibodies detectable by widely available commercial tests.

    Science.gov (United States)

    Mahler, Michael; Satoh, Minoru; Hudson, Marie; Baron, Murray; Chan, Jason Y F; Chan, Edward K L; Wick, James; Fritzler, Marvin J

    2014-07-01

    Antinuclear antibodies (ANA) occur in up to 95% of patients with systemic sclerosis (SSc). In most, SSc-associated antibodies are detected (i.e., centromere, topoisomerase I, RNA polymerase III, PM/Scl, Ro52/TRIM21, and U1RNP). Ribonuclease P protein subunit p25, (Rpp25) is an autoantigenic component of the Th/To complex. The contribution of anti-Th/To and anti-Rpp25 antibodies to ANA positivity in patients with SSc remains unknown. Sera from 873 patients with SSc were tested for ANA, and SSc-associated antibodies were measured. Samples without antibodies to extractable nuclear antigens (ENA; n = 53, ANA+/ENA-), were analyzed by immunoprecipitation (IP) and metabolically labeled proteins and for anti-Rpp25 antibodies (n = 50) by a chemiluminescent immunoassay (CLIA) and Rpp25 ELISA. Anti-Th/To antibodies occurred in 19/53 (36%), as determined by IP, and were the most common autoantibody in ANA+/ENA- SSc. Of those samples, 50/53 were available for additional testing by CLIA and ELISA. Anti-Rpp25 antibodies were detected in 12 (24% CLIA) or 10 (20% ELISA) of 50 patients. Receiver-operating characteristic curve analysis showed similar discrimination between Th/To IP-positive (n = 19) and -negative samples (n = 31) by CLIA and ELISA (area under the curve 0.90 vs 0.87; p = 0.6691). The positive percent agreement between IP and CLIA or ELISA was 12/19 (63.2%, 95% CI 38.4-83.7%) or 10/19 (52.6%, 95% CI 73.3-94.2%), respectively. Negative percent agreement was 100% for both assays. Autoantibodies to the Th/To autoantigen are important in patients with SSc who have been considered negative for SSc-specific or SSc-associated antibodies by widely available commercial assays. Rpp25 can be considered a major target of anti-Th/To antibodies. Assays detecting anti-Th/To and anti-Rpp25 antibodies may be important in SSc.

  10. Survey of commercially available chocolate- and cocoa-containing products in the United States. 2. Comparison of flavan-3-ol content with nonfat cocoa solids, total polyphenols, and percent cacao.

    Science.gov (United States)

    Miller, Kenneth B; Hurst, W Jeffrey; Flannigan, Nancy; Ou, Boxin; Lee, C Y; Smith, Nancy; Stuart, David A

    2009-10-14

    A survey of a broad range of chocolate- and cocoa-containing products marketed in the United States was conducted to provide a more detailed analysis of flavan-3-ol monomers, oligomers, and polymers, which can be grouped into a class of compounds called procyanidins. Samples consisted of the three or four top-selling products within the following six categories: natural cocoa powder, unsweetened baking chocolate, dark chocolate, semisweet baking chips, milk chocolate, and chocolate syrup. Composite samples were characterized for percent fat (% fat), percent nonfat cocoa solids (% NFCS), antioxidant level by ORAC, total polyphenols, epicatechin, catechin, total monomers, and flavan-3-ol oligomers and polymers (procyanidins). On a gram weight basis epicatechin and catechin content of the products follow in decreasing order: cocoa powder > baking chocolate > dark chocolate = baking chips > milk chocolate > chocolate syrup. Analysis of the monomer and oligomer profiles within product categories shows there are two types of profiles: (1) products that have high monomers with decreasing levels of oligomers and (2) products in which the level of dimers is equal to or greater than the monomers. Results show a strong correlation (R(2) = 0.834) of epicatechin to the level of % NFCS and also very good correlations for N = 2-5 oligomers to % NFCS. A weaker correlation was observed for catechin to % NFCS (R(2) = 0.680). Other analyses show a similar high degree of correlation with epicatechin and N = 2-5 oligomers to total polyphenols, with catechin being less well correlated to total polyphenols. A lesser but still good correlation exists between the calculated percent cacao (calcd % cacao) content, a proxy for percent cacao, and these same flavanol measures, with catechin again showing a lesser degree of correlation to calcd % cacao. Principal component analysis (PCA) shows that the products group discretely into five classes: (1) cocoa powder, (2) baking chocolate, (3) dark

  11. Therapeutic ultrasound as a potential male contraceptive: power, frequency and temperature required to deplete rat testes of meiotic cells and epididymides of sperm determined using a commercially available system.

    Science.gov (United States)

    Tsuruta, James K; Dayton, Paul A; Gallippi, Caterina M; O'Rand, Michael G; Streicker, Michael A; Gessner, Ryan C; Gregory, Thomas S; Silva, Erick J R; Hamil, Katherine G; Moser, Glenda J; Sokal, David C

    2012-01-30

    Studies published in the 1970s by Mostafa S. Fahim and colleagues showed that a short treatment with ultrasound caused the depletion of germ cells and infertility. The goal of the current study was to determine if a commercially available therapeutic ultrasound generator and transducer could be used as the basis for a male contraceptive. Sprague-Dawley rats were anesthetized and their testes were treated with 1 MHz or 3 MHz ultrasound while varying power, duration and temperature of treatment. We found that 3 MHz ultrasound delivered with 2.2 Watt per square cm power for fifteen minutes was necessary to deplete spermatocytes and spermatids from the testis and that this treatment significantly reduced epididymal sperm reserves. 3 MHz ultrasound treatment reduced total epididymal sperm count 10-fold lower than the wet-heat control and decreased motile sperm counts 1,000-fold lower than wet-heat alone. The current treatment regimen provided nominally more energy to the treatment chamber than Fahim's originally reported conditions of 1 MHz ultrasound delivered at 1 Watt per square cm for ten minutes. However, the true spatial average intensity, effective radiating area and power output of the transducers used by Fahim were not reported, making a direct comparison impossible. We found that germ cell depletion was most uniform and effective when we rotated the therapeutic transducer to mitigate non-uniformity of the beam field. The lowest sperm count was achieved when the coupling medium (3% saline) was held at 37 degrees C and two consecutive 15-minute treatments of 3 MHz ultrasound at 2.2 Watt per square cm were separated by 2 days. The non-invasive nature of ultrasound and its efficacy in reducing sperm count make therapeutic ultrasound a promising candidate for a male contraceptive. However, further studies must be conducted to confirm its efficacy in providing a contraceptive effect, to test the result of repeated use, to verify that the contraceptive effect is

  12. Simultaneous bilateral isolated greater trochanter fracture

    Directory of Open Access Journals (Sweden)

    Maruti Kambali

    2013-01-01

    Full Text Available A 48-year-old woman sustained simultaneous isolated bilateral greater trochanteric fracture, following a road traffic accident. The patient presented to us 1 month after the injury. She presented with complaints of pain in the left hip and inability to walk. Roentgenograms revealed displaced comminuted bilateral greater trochanter fractures. The fracture of the left greater trochanter was reduced and fixed internally using the tension band wiring technique. The greater trochanter fracture on the right side was asymptomatic and was managed conservatively. The patient regained full range of motion and use of her hips after a postoperative follow-up of 6 months. Isolated fractures of the greater trochanter are unusual injuries. Because of their relative rarity and the unsettled controversy regarding their etiology and pathogenesis, several methods of treatment have been advocated. Furthermore, the reports of this particular type of injury are not plentiful and the average textbook coverage afforded to this entity is limited. In our study we discuss the mechanism of injury and the various treatment options available.

  13. Analytical properties of some commercially available nitrate reductase enzymes evaluated as replacements for cadmium in automated, semiautomated, and manual colorimetric methods for determination of nitrate plus nitrite in water

    Science.gov (United States)

    Patton, Charles J.; Kryskalla, Jennifer R.

    2013-01-01

    A multiyear research effort at the U.S. Geological Survey (USGS) National Water Quality Laboratory (NWQL) evaluated several commercially available nitrate reductase (NaR) enzymes as replacements for toxic cadmium in longstanding automated colorimetric air-segmented continuous-flow analyzer (CFA) methods for determining nitrate plus nitrite (NOx) in water. This research culminated in USGS approved standard- and low-level enzymatic reduction, colorimetric automated discrete analyzer NOx methods that have been in routine operation at the NWQL since October 2011. The enzyme used in these methods (AtNaR2) is a product of recombinant expression of NaR from Arabidopsis thaliana (L.) Heynh. (mouseear cress) in the yeast Pichia pastoris. Because the scope of the validation report for these new automated discrete analyzer methods, published as U.S. Geological Survey Techniques and Methods 5–B8, was limited to performance benchmarks and operational details, extensive foundational research with different enzymes—primarily YNaR1, a product of recombinant expression of NaR from Pichia angusta in the yeast Pichia pastoris—remained unpublished until now. This report documents research and development at the NWQL that was foundational to development and validation of the discrete analyzer methods. It includes: (1) details of instrumentation used to acquire kinetics data for several NaR enzymes in the presence and absence of known or suspected inhibitors in relation to reaction temperature and reaction pH; and (2) validation results—method detection limits, precision and bias estimates, spike recoveries, and interference studies—for standard- and low-level automated colorimetric CFA-YNaR1 reduction NOx methods in relation to corresponding USGS approved CFA cadmium-reduction (CdR) NOx methods. The cornerstone of this validation is paired sample statistical and graphical analysis of NOx concentrations from more than 3,800 geographically and seasonally diverse surface

  14. Search for greater stability in nuclear regulation

    International Nuclear Information System (INIS)

    Asselstine, J.K.

    1985-01-01

    The need for greater stability in nuclear regulation is discussed. Two possible approaches for dealing with the problems of new and rapidly changing regulatory requirements are discussed. The first approach relies on the more traditional licensing reform initiatives that have been considered off and on for the past decade. The second approach considers a new regulator philosophy aimed at the root causes of the proliferation of new safety requirements that have been imposed in recent years. For the past few years, the concepts of deregulation and regulatory reform have been in fashion in Washington, and the commercial nuclear power program has not remained unaffected. Many look to these concepts to provide greater stability in the regulatory program. The NRC, the nuclear industry and the administration have all been avidly pursuing regulatory reform initiatives, which take the form of both legislative and administrative proposals. Many of these proposals look to the future, and, if adopted, would have little impact on currently operating nuclear power plants or plants now under construction

  15. [Autoerotic fatalities in Greater Dusseldorf].

    Science.gov (United States)

    Hartung, Benno; Hellen, Florence; Borchard, Nora; Huckenbeck, Wolfgang

    2011-01-01

    Autoerotic fatalities in the Greater Dusseldorf area correspond to the relevant medicolegal literature. Our results included exclusively young to middle-aged, usually single men who were found dead in their city apartments. Clothing and devices used showed a great variety. Women's or fetish clothing and complex shackling or hanging devices were disproportionately frequent. In most cases, death occurred due to hanging or ligature strangulation. There was no increased incidence of underlying psychiatric disorders. In most of the deceased no or at least no remarkable alcohol intoxication was found. Occasionally, it may be difficult to reliably differentiate autoerotic accidents, accidents occurring in connection with practices of bondage & discipline, dominance & submission (BDSM) from natural death, suicide or homicide.

  16. Planning for greater confinement disposal

    International Nuclear Information System (INIS)

    Gilbert, T.L.; Luner, C.; Meshkov, N.K.; Trevorrow, L.E.; Yu, C.

    1985-01-01

    A report that provides guidance for planning for greater-confinement disposal (GCD) of low-level radioactive waste is being prepared. The report addresses procedures for selecting a GCD technology and provides information for implementing these procedures. The focus is on GCD; planning aspects common to GCD and shallow-land burial are covered by reference. Planning procedure topics covered include regulatory requirements, waste characterization, benefit-cost-risk assessment and pathway analysis methodologies, determination of need, waste-acceptance criteria, performance objectives, and comparative assessment of attributes that support these objectives. The major technologies covered include augered shafts, deep trenches, engineered structures, hydrofracture, improved waste forms, and high-integrity containers. Descriptive information is provided, and attributes that are relevant for risk assessment and operational requirements are given. 10 refs., 3 figs., 2 tabs

  17. Impact of the subprime crisis on commercial banks’ financial performance

    Directory of Open Access Journals (Sweden)

    Fang Hao

    2013-01-01

    Full Text Available We investigated changes in the financial performance of representatives of the world’s top 200 commercial banks after the global subprime financial crisis. Our empirical results show that following the subprime-crisis disclosure, all commercial banks exhibited worse performance in asset quality, profitability, liquidity, and growth index, accompanied by risk increases in asset adequacy, managerial ability, profitability, and growth index. Developed markets have suffered a greater negative influence than emerging markets, causing downward pressure on asset adequacy, asset quality, and profitability since the subprime crisis. Commercial banks within developed nations suffered more direct pronounced effects from the subprime crisis than did those in emerging markets. Our results prove that larger commercial banks, particularly those with larger capitalization, have the economies-of-scale advantage to resist the negative effects of economic downturns.

  18. Commercial applications

    International Nuclear Information System (INIS)

    Anon.

    1982-01-01

    The objective of this paper is to assess the near term (one-to-five-year) needs of domestic and foreign commercial suppliers of radiochemicals and radiopharmaceuticals for electromagnetically separated stable isotopes. Only isotopes purchased to make products for sale and profit are considered in this assessment. Radiopharmaceuticals produced from enriched stable isotopes supplied by the Calutron facility at ORNL are used in about 600,000 medical procedures each year in the United States. A temporary or permanent disruption of the supply of stable isotopes to the domestic radiopharmaceutical industry could curtail, if not eliminate, the use of such diagnostic procedures as the thallium heart scan, the gallium cancer scan, the gallium abscess scan, and the low-radiation-dose thyroid scan. The word could in the preceding sentence is underlined because an alternative source of enriched stable isotopes does exist in the USSR. Alternative starting materials could, in theory, eventually be developed for both the thallium and gallium scans. The development of a new technology for these purposes, however, would take at least five years and would be expensive. Hence, any disruption of the supply of enriched isotopes from ORNL and the resulting unavailability of critical nuclear medicine procedures would have a dramatic negative effect on the level of health care in the United States

  19. Commercial applications

    Science.gov (United States)

    The near term (one to five year) needs of domestic and foreign commercial suppliers of radiochemicals and radiopharmaceuticals for electromagnetically separated stable isotopes are assessed. Only isotopes purchased to make products for sale and profit are considered. Radiopharmaceuticals produced from enriched stable isotopes supplied by the Calutron facility at ORNL are used in about 600,000 medical procedures each year in the United States. A temporary or permanent disruption of the supply of stable isotopes to the domestic radiopharmaceutical industry could curtail, if not eliminate, the use of such diagnostic procedures as the thallium heart scan, the gallium cancer scan, the gallium abscess scan, and the low radiation dose thyroid scan. An alternative source of enriched stable isotopes exist in the USSR. Alternative starting materials could, in theory, eventually be developed for both the thallium and gallium scans. The development of a new technology for these purposes, however, would take at least five years and would be expensive. Hence, any disruption of the supply of enriched isotopes from ORNL and the resulting unavailability of critical nuclear medicine procedures would have a dramatic negative effect on the level of health care in the United States.

  20. Commercial Conspiracy Theories

    Directory of Open Access Journals (Sweden)

    Adrian eFurnham

    2013-06-01

    Full Text Available There are many ways to categorise conspiracy theories. In the present study, we examined individual and demographic predictors of beliefs in commercial conspiracy theories among a British sample of over 300 women and men. Results showed people were cynical and sceptical with regard to advertising tricks, as well as the tactics of organisations like banks and alcohol, drug and tobacco companies. Beliefs sorted into four identifiable clusters, labelled sneakiness, manipulative, change-the-rules and suppression/prevention. The high alpha for the overall scale suggested general beliefs in commercial conspiracy. Regressions suggested that those people who were less religious, more left-wing, more pessimistic, less (self-defined as wealthy, less Neurotic and less Open-to-Experience believed there was more commercial conspiracy. Overall the individual difference variables explained relatively little of the variance in these beliefs.The implications of these findings for the literature on conspiracy theories are discussed.

  1. Commercial and Institutional Waste

    DEFF Research Database (Denmark)

    Christensen, Thomas Højlund; Fruergaard, Thilde

    2011-01-01

    Commercial and institutional waste is primarily from retail (stores), hotels, restaurants, health care (except health risk waste), banks, insurance companies, education, retirement homes, public services and transport. Within some of these sectors, e.g. retail and restaurants, large variations...... are found in terms of which products and services are offered. Available data on unit generation rates and material composition as well as determining factors are discussed in this chapter. The characterizing of commercial and institutional waste is faced with the problem that often only a part of the waste...... is handled in the municipal waste system, where information is easily accessible. An important part of commercial and institutional waste is packaging waste, and enterprises with large quantities of clean paper, cardboard and plastic waste may have their own facilities for baling and storing their waste...

  2. Efficient automated synthesis of 2-(5-["1"8F]fluoropentyl)-2-methylmalonic acid (["1"8F]ML-10) on a commercial available ["1"8F]FDG synthesis module

    International Nuclear Information System (INIS)

    Liu, Shaoyu; Nie, Dahong; Jiang, Shende; Tang, Ganghua

    2017-01-01

    ["1"8F]ML-10 (2-(5-["1"8F]fluoro-pentyl)-2-methylmalonic acid) is a small molecule positron emission tomography (PET) probe for apoptosis imaging. Automated synthesis of ["1"8F]ML-10 was developed by using two different purification methods through a direct saponification procedure on a modified commercial ["1"8F]Fluoro-2-Deoxyglucose (["1"8F]FDG) synthesizer. C18 purification method 1: The final ["1"8F]ML-10 solution containing ethanol was obtained with radiochemical yields of 60±5% (n=5) at the end of bombardment (EOB) and radiochemical purity of 98% in 35 min. Al_2O_3 and SCX purification method 2: To avoid possible side effects of a conventional ethanol-containing formulation, an new ethanol-free solution of ["1"8F]ML-10 was also developed, the radiochemical yields was 50±5% (n=5, EOB) within 45 min and the radiochemical purity was 98%. - Highlights: • The production of ["1"8F]ML-10 was optimized by using a straightforward saponification procedure. • Automated synthesis was performed on a commonly FDG synthesis module. • An ethanol-containing ["1"8F]ML-10 formulation was obtained with high radiochemical yield in a shorter time. • An ethanol-free formulation method of ["1"8F]ML-10 was also developed.

  3. Greater utilization of wood residue fuels through improved financial planning

    International Nuclear Information System (INIS)

    Billings, C.D.; Ziemke, M.C.; Stanford, R.

    1991-01-01

    Recent events have focused attention on the promotion of greater utilization of biomass fuel. Considerations include the need to reduce increases in global warming and also to improve ground level air quality by limiting the use of fossil fuels. However, despite all these important environmentally related considerations, economics remains the most important factor in the decision process used to determine the feasibility of using available renewable fuels instead of more convenient fossil fuels. In many areas of the Southeast, this decision process involves choosing between wood residue fuels such as bark, sawdust and shavings and presently plentiful natural gas. The primary candidate users of wood residue fuels are industries that use large amounts of heat and electric power and are located near centers of activity in the forest products industry such as sawmills, veneer mills and furniture factories. Given that such facilities both produce wood residues and need large amounts of heat and electricity, it is understandable that these firms are often major users of wood-fired furnaces and boilers. The authors have observed that poor or incomplete financial planning by the subject firms is a major barrier to economic utilization of inexpensive and widely available renewable fuels. In this paper, the authors suggest that wider usage of improved financial planning could double the present modest annual incidence of new commercial wood-fueled installation

  4. Status on disposal of greater-than-Class C

    Energy Technology Data Exchange (ETDEWEB)

    Plummer, T.L.

    1995-12-31

    The Department of Energy (DOE) has developed a plan for the management and disposal of commercially generated greater-than-Class C (GTCC) low-level radioactive waste. The Low-Level Radioactive Waste Policy Amendments Act of 1985 made DOE responsible for disposal of GTCC waste. The act requires that GTCC waste be disposed in a Nuclear Regulatory Commission (NRC)-licensed facility. The NRC has amended 10 CFR 61 to express a preference for geologic disposal of GTCC waste. Based on reassessment studies, legislative guidance, and stakeholder involvement, a revised plan has been formulated to provide for total management of GTCC waste. The plan has four major thrusts: (1) plan for GTCC waste storage at the generator site until disposal is available, (2) establish storage for GTCC sealed sources posing health and safety risk to the public, (3) facilitate storage for other GTCC waste posing health and safety risk to the public, and (4) plan for co-disposal of GTCC waste in a geologic disposal site with similar waste types. The revised plan focuses on applying available resources to near- and long-term needs.

  5. Waste management in Greater Vancouver

    Energy Technology Data Exchange (ETDEWEB)

    Carrusca, K. [Greater Vancouver Regional District, Burnaby, BC (Canada); Richter, R. [Montenay Inc., Vancouver, BC (Canada)]|[Veolia Environmental Services, Vancouver, BC (Canada)

    2006-07-01

    An outline of the Greater Vancouver Regional District (GVRD) waste-to-energy program was presented. The GVRD has an annual budget for solid waste management of $90 million. Energy recovery revenues from solid waste currently exceed $10 million. Over 1,660,00 tonnes of GVRD waste is recycled, and another 280,000 tonnes is converted from waste to energy. The GVRD waste-to-energy facility combines state-of-the-art combustion and air pollution control, and has processed over 5 million tonnes of municipal solid waste since it opened in 1988. Its central location minimizes haul distance, and it was originally sited to utilize steam through sales to a recycle paper mill. The facility has won several awards, including the Solid Waste Association of North America award for best facility in 1990. The facility focuses on continual improvement, and has installed a carbon injection system; an ammonia injection system; a flyash stabilization system; and heat capacity upgrades in addition to conducting continuous waste composition studies. Continuous air emissions monitoring is also conducted at the plant, which produces a very small percentage of the total air emissions in metropolitan Vancouver. The GVRD is now seeking options for the management of a further 500,000 tonnes per year of solid waste, and has received 23 submissions from a range of waste energy technologies which are now being evaluated. It was concluded that waste-to-energy plants can be located in densely populated metropolitan areas and provide a local disposal solution as well as a source of renewable energy. Other GVRD waste reduction policies were also reviewed. refs., tabs., figs.

  6. Places available**

    CERN Multimedia

    2003-01-01

    If you wish to participate in one of the following courses, please discuss with your supervisor and apply electronically directly from the course description pages that can be found on the Web at: http://www.cern.ch/Training/ or fill in an "application for training" form available from your Divisional Secretariat or from your DTO (Divisional Training Officer). Applications will be accepted in the order of their receipt. TECHNICAL TRAINING Monique Duval tel. 74924 technical.training@cern.ch ** The number of places available may vary. Please check our Web site to find out the current availability. Places are available in the following courses: ACCESS 2000 - niveau 1 : 13 & 14.11.03 (2 jours) C++ for Particle Physicists : 17 – 21.11.03 (6 X 3-hour lectures) Programmation automate Schneider TSX Premium – niveau 2 : 18 – 21.11.03 (4 jours) JAVA 2 Enterprise Edition – Part 1 : WEB Applications : 20 & ...

  7. Commercial forestry

    CSIR Research Space (South Africa)

    Naidoo, Sasha

    2017-10-01

    Full Text Available states. Forest cover is concentrated in a few countries in the SADC region. The Democratic Republic of Congo, Angola, Zambia and Mozambique have the largest forest areas and account for close to three-quarters of the total forest area in the SADC region...

  8. Places available

    CERN Multimedia

    2004-01-01

    If you wish to participate in one of the following courses, please discuss with your supervisor and apply electronically directly from the course description pages that can be found on the Web at: http://www.cern.ch/Training/ or fill in an "application for training" form available from your Divisional Secretariat or from your DTO (Divisional Training Officer). Applications will be accepted in the order of their receipt. Places available The number of places available may vary. Please check our Web site to find out the current availability. Places are available in the following courses : Introduction à Outlook : 19.8.2004 (1 journée) Outlook (short course I) : E-mail : 31.8.2004 (2 hours, morning) Outlook (short course II) : Calendar, Tasks and Notes : 31.8.2004 (2 hours, afternoon) Instructor-led WBTechT Study or Follow-up for Microsoft Applications : 7.9.2004 (morning) Outlook (short course III) : Meetings and Delegation : 7.9.2004 (2 hours, afternoon) Introduction ...

  9. Places available**

    CERN Multimedia

    2003-01-01

    If you wish to participate in one of the following courses, please discuss with your supervisor and apply electronically directly from the course description pages that can be found on the Web at: http://www.cern.ch/Training/ or fill in an "application for training" form available from your Divisional Secretariat or from your DTO (Divisional Training Officer). Applications will be accepted in the order of their receipt. TECHNICAL TRAINING Monique Duval Tel. 74924technical.training@cern.ch ** The number of places available may vary. Please check our Web site to find out the current availability. Places are available in the following courses: MATLAB Fundamentals and Programming Techniques (ML01) : 2 & 3.12.03 (2 days) Oracle 8i : SQL : 3 - 5.12.03 (3 days) The EDMS MTF in practice : 5.12.03 (afternoon, free of charge) Modeling Dynamic Systems with Simulink (SL01) : 8 & 9.12.03 (2 days) Signal Processing with MATLAB (SG01) : 11 & 12.12.03 (2 days) The JAVA Programming Language - l...

  10. Places available**

    CERN Multimedia

    2003-01-01

    If you wish to participate in one of the following courses, please discuss with your supervisor and apply electronically directly from the course description pages that can be found on the Web at: http://www.cern.ch/Training/ or fill in an "application for training" form available from your Divisional Secretariat or from your DTO (Divisional Training Officer). Applications will be accepted in the order of their receipt. TECHNICAL TRAINING Monique Duval tel. 74924 technical.training@cern.ch ** The number of places available may vary. Please check our Web site to find out the current availability. Places are available in the following courses: MATLAB Fundamentals and Programming Techniques (ML01) :2 & 3.12.03 (2 days) Oracle 8i : SQL : 3 - 5.12.03 (3 days) The EDMS MTF in practice : 5.12.03 (afternoon, free of charge) Modeling Dynamic Systems with Simulink (SL01) : 8 & 9.12.03 (2 days) Signal Processing with MATLAB (SG01) : 11 & ...

  11. Places available**

    CERN Multimedia

    2004-01-01

    If you wish to participate in one of the following courses, please discuss with your supervisor and apply electronically directly from the course description pages that can be found on the Web at: http://www.cern.ch/Training/ or fill in an "application for training" form available from your Divisional Secretariat or from your DTO (Divisional Training Officer). Applications will be accepted in the order of their receipt.TECHNICAL TRAINING Monique Duval tel. 74924 technical.training@cern.ch ** The number of places available may vary. Please check our Web site to find out the current availability. Places are available in the following courses: The JAVA Programming Language Level 1 : 9 & 10.1.2004 (2 days) The JAVA Programming Language Level 2 : 11 to 13.1.2004 (3 days) LabVIEW base 1 : 25 - 27.2.2004 (3 jours) CLEAN-2002 : Working in a Cleanroom : 10.3.2004 (afternoon - free of charge) C++ for Particle Physicists : 8 - 12.3.2004 ( 6 X 4-hour sessions) LabVIEW Basics 1 : 22 - 24.3.20...

  12. Places available**

    CERN Document Server

    2004-01-01

    If you wish to participate in one of the following courses, please discuss with your supervisor and apply electronically directly from the course description pages that can be found on the Web at: http://www.cern.ch/Training/ or fill in an "application for training" form available from your Divisional Secretariat or from your DTO (Divisional Training Officer). Applications will be accepted in the order of their receipt. TECHNICAL TRAINING Monique Duval tel. 74924 technical.training@cern.ch ** The number of places available may vary. Please check our Web site to find out the current availability. Places are available in the following courses: The JAVA Programming Language Level 1 :9 & 10.1.2004 (2 days) The JAVA Programming Language Level 2 : 11 to 13.1.2004 (3 days) Hands-on Introduction to Python Programming : 16 - 18.2.2004 (3 days - free of charge) CLEAN-2002 : Working in a Cleanroom : 10.3.2004 (afternoon - free of charge) C++ for Particle Physicists : 8 - 12.3.2004...

  13. Places available**

    CERN Document Server

    2003-01-01

    If you wish to participate in one of the following courses, please discuss with your supervisor and apply electronically directly from the course description pages that can be found on the Web at: http://www.cern.ch/Training/ or fill in an "application for training" form available from your Divisional Secretariat or from your DTO (Divisional Training Officer). Applications will be accepted in the order of their receipt. TECHNICAL TRAINING Monique Duval Tel. 74924 technical.training@cern.ch ** The number of places available may vary. Please check our Web site to find out the current availability. Places are available in the following courses: JAVA 2 Enterprise Edition - Part 1 : WEB Applications : 20 & 21.11.03(2 days) FrontPage 2000 - niveau 1 : 20 & 21.11.03 (2 jours) Oracle 8i : SQL : 3 - 5.12.03 (3 days) Oracle 8i : Programming with PL/SQL : 8 - 10.12.03 (3 days) The JAVA Programming Language - leve...

  14. Places available**

    CERN Multimedia

    2003-01-01

    If you wish to participate in one of the following courses, please discuss with your supervisor and apply electronically directly from the course description pages that can be found on the Web at: http://www.cern.ch/Training/ or fill in an "application for training" form available from your Divisional Secretariat or from your DTO (Divisional Training Officer). Applications will be accepted in the order of their receipt. TECHNICAL TRAINING Monique Duval tel. 74924 technical.training@cern.ch ** The number of places available may vary. Please check our Web site to find out the current availability. Places are available in the following courses: Project Planning with MS-Project : 15 & 22.1.2004 (2 days) Joint PVSS JCOP Framework Course : 2 sessions : 2 - 6.2.2004 and 16 - 20-2-2004 (5 days) Hands-on Introduction to Python Programming : 16 - 18.2.2004 (3 days - free of charge) C++ for Particle Physicists : 8 - 12.3.2004 ( 6 X 4-hour sessions)

  15. Places available**

    CERN Multimedia

    2003-01-01

    If you wish to participate in one of these courses, please discuss with your supervisor and apply electronically directly from the course description pages that can be found on the Web at: http://www.cern.ch/Training/ or fill in an "application for training" form available from your Divisional Secretariat or from your DTO (Divisional Training Officer). Applications will be accepted in the order of their receipt. ** The number of places available may vary. Please check our Web site to find out the current availability. Places are available in the following courses : EXCEL 2000 - niveau 1 : 20 & 22.10.03 (2 jours) CLEAN-2002 : Working in a Cleanroom (free of charge) : 23.10.03 (half day) The EDMS-MTF in practice (free of charge) :  28 -  30.10.03 (6 half-day sessions) AutoCAD 2002 - Level 1 : 3, 4, 12, 13.11.03 (4 days) LabVIEW TestStand ver. 3 : 4 & 5.11.03 (2 days) Introduction to Pspice : 4.11.03 p.m. (half-day) Hands-on Introduction to Python Programm...

  16. [Not Available].

    Science.gov (United States)

    Ackerman, E

    1977-01-01

    Acceptance of birth control increased greatly among the inhabitants of Bonnieres, a French community situated on the left bank of the Seine, immediately following the 1789-1799 French Revolution. Increased acceptance of birth control was attributed to the general questioning of traditional values and beliefs which occurred during and immediately following the revolution. The revolutionary spirit allowed individuals to feel a greater sense of control over their own destiny. Prior to the revolution, Catholic teaching concerning sexual matters were followed by almost all of the inhabitants of Bonnieres. During the period 1736-1785 there was some increase in birth control acceptance, but the changes were slight compared to those which occurred following the revolution. During 1736-1785, average completed family size decreased slight from 5.8-5.6; however during 1786-1815, average completed family size was 3.9 and during the period 1816-1845, it was 2.9. An examination of changes in birth intervals suggested that during the period 1756-1785, 9.2-18.0% of the population practiced some form of birth control while 37.8-42.8% of the population practiced birth control during the period 1786-1815. An examination of age specific fertility rates further demonstrated that the major increase in birth control practice occurred immediately following the revolution. Birth control acceptance occurred despite a continuing infant mortality rate of 123-195/1000 throughout the 1700s and 1800s. Tables provided data on age specific fertility rates and on birth intervals for females in Bonnieres for 1736-1845.

  17. PLACES AVAILABLE

    CERN Multimedia

    Technical Training; Tel. 74924

    2001-01-01

    Places are available in the following courses: Introduction to Databases :  3 - 4.7.01 (2 days) The JAVA programming language Level 2 : 4 - 6.7.01 (3 days) Enterprise JavaBeans :  9 - 11.7.01 (3 days) Design Patterns :  10 - 12.7.01 (3 days) C++ for Particle Physicists :  23 - 27.7.01 (6 3-hour lectures) If you wish to participate in one of these courses, please discuss with your supervisor and apply electronically directly from the course description pages that can be found on the Web at : http://www.cern.ch/Training/ or fill in an 'application for training' form available from your Divisional Secretariat or from your DTO (Divisional Training Officer). Applications will be accepted in the order of their receipt.

  18. PLACES AVAILABLE

    CERN Multimedia

    Technical Training; Tel. 74924

    2001-01-01

    Places are available in the following courses: Introduction to Perl 5 : 2 - 3.7.01 (2 days) Introduction to Databases :  3 - 4.7.01 (2 days) JAVA programming language Level 2 : 4 - 6.7.01 (3 days) Enterprise JavaBeans :  9 - 11.7.01 (3 days) Design Patterns :  10 - 12.7.01 (3 days) C++ for Particle Physicists :  23 - 27.7.01 (6 3-hour lectures) If you wish to participate in one of these courses, please discuss with your supervisor and apply electronically directly from the course description pages that can be found on the Web at : http://www.cern.ch/Training/ or fill in an 'application for training' form available from your Divisional Secretariat or from your DTO (Divisional Training Officer). Applications will be accepted in the order of their receipt.

  19. PLACES AVAILABLE

    CERN Multimedia

    Monique Duval

    2002-01-01

    Places are available in the following courses: CLEAN-2002 : Travailler en salle blanche (cours gratuit) : 13.08.2002 (matin) Introduction to the CERN Enginnering Data Management System :  27.8.02  (1 day) The CERN Engineering Data Management System for Advanced Users :  28.8.02  (1 day) If you wish to participate in one of these courses, please discuss with your supervisor and apply electronically directly from the course description pages that can be found on the Web at : Technical Training or fill in an 'application for training' form available from your Divisional Secretariat or from your DTO (Divisional Training Officer). Applications will be accepted in the order of their receipt. Technical Training Monique Duval Tel.74924 monique.duval@cern.ch    

  20. PLACES AVAILABLE

    CERN Multimedia

    Monique Duval

    2002-01-01

    Places are available in the following courses: C++ Programming Level 2 - Traps & Pitfalls:  16 - 19.7.02 (4 days) Frontpage 2000 - level 1 :  22 - 23.7.02  (2 days) Introduction à Windows 2000 au CERN : 24.7.02 (après-midi) CLEAN-2002 : Travailler en salle blanche (cours gratuit) : 13.08.2002 (matin) If you wish to participate in one of these courses, please discuss with your supervisor and apply electronically directly from the course description pages that can be found on the Web at : Technical Training or fill in an 'application for training' form available from your Divisional Secretariat or from your DTO (Divisional Training Officer). Applications will be accepted in the order of their receipt. Technical Training Monique Duval Tel.74924 monique.duval@cern.ch

  1. PLACES AVAILABLE

    CERN Multimedia

    Monique Duval

    2002-01-01

    Places are available in the following courses: December 2002   PCAD Schémas - Débutants :  5 & 6.12.02  (2 jours) PCAD PCB - Débutants :  9 - 11.12.02  (3 jours) FrontPage 2000 - level 1:  9 & 10.12.02  (2 days) Introduction à la CAO Cadence (cours gratuit) :  10 & 11.12.02  (2 jours) If you wish to participate in one of these courses, please discuss with your supervisor and apply electronically directly from the course description pages that can be found on the Web at : Technical Training or fill in an 'application for training' form available from your Divisional Secretariat or from your DTO (Divisional Training Officer). Applications will be accepted in the order of their receipt. Technical Training Monique Duval Tel.74924 monique.duval@cern.ch

  2. Places available**

    CERN Multimedia

    2003-01-01

    Places are available in the following courses: Conception de PCB rapides dans le flot Cadence : 11.6.03 (matin) EXCEL 2000 - level 1 : 12 & 13.6.03 (2 days) Introduction to PVSS : 16.6.03 (p.m.) Basic PVSS : 17 - 19.6.03 (3 days) Réalisation de PCB rapides dans le flot Cadence : 17.6.03 (matin) PVSS - JCOP Framework Tutorial : 20.6.03 (1 day) Programmation automate Schneider : Programmation automate Schneider TSX Premium - 2ème niveau : 24 - 27.6.03 (4 jours) - audience : toute personne qui veux maitriser la mise en uvre et la programmation des fonctions spécialisées d'un automate TSX Premium - objectifs : maitriser la mise en uvre et la programmation des fonctions spécialisées d'un automate TSX Premium Cours de sécurité : Etre TSO au CERN : Prochaines sessions : 24, 25 & 27.6.03 - 4, 5 & 7.11.03 (session de 3 jours) ** The number of places available may vary. Please check our Web site to find out the current availability. If you wish to participate in one of these courses, pl...

  3. PLACES AVAILABLE

    CERN Multimedia

    Enseignement Technique; Tél. 74924; Technical Training; Monique Duval; Tel. 74924

    2000-01-01

    Places available Places are available in the following courses:   LabView hands-on 13.11.00 4 hours LabView Basics 1 14 - 16.11.00 3 days Nouveautés de WORD 19 et 20.10.00 2 jours ACCESS 1er niveau 30 - 31.10.00 2 jours Advanced aspects of the C language 2 - 3.11.00 2 days Introduction to Oracle SQL and PL/SQL 13 - 17.11.00 5 days C++ for Particle Physicists 20 - 24.11.00 6 lectures Develop PL/SQL Program Units 20 - 22.11.00 3 days Oracle Application Server Develop Web-Based Applications with PL/SQL 27 - 28.11.00 2 days Programmation TSX Premium 1 28.11 - 1.12.00 4 jours Programmation TSX Premium 2 12 - 15.12.00 4 jours If you wish to participate in one of these courses, please discuss with your supervisor and apply electronically directly from the course description pages that can be found on the Web at : http://www.cern.ch/Training/ or fill in an “application for training” form available from your Divisional Secretariat or from your DTO (Divisional Training Offi...

  4. Places available**

    CERN Multimedia

    Places are available in the following courses: Hands-on Introduction to Python Programming: 11-13.08.2003 (3 days) Introduction to the CERN Engineering Data Management System (EDMS): 26.08.2003 (1 day) The CERN Engineering Data Management System (EDMS) for Engineers: 27.08.2003 (1 day) CLEAN-2002 : Travailler en salle blanche : 4.09.2003 (une demi-journée) AutoCAD 2002 - Level 1: 4, 5, 15, 16.09.2003 (2 x 2 days) AutoCAD Mechanical 6 PowerPack : 17, 18, 25, 26.09.2003 et 2, 3.10.2003 (3 x 2 journées, français) AutoCAD 2002 - niveau 1 : 23, 24, 30.09.2003 et 1.10.2003 (2 x 2 journées) Introduction to the CERN Engineering Data Management System (EDMS): 23.09.2003 (1 day) The CERN Engineering Data Management System (EDMS) for Local Administrators: 24-25.09.2003 (2 days) AutoCAD 2002 - niveau 2 : 8 et 10.10.2003 (2 journées) CLEAN-2002: Working in a Cleanroom: 23.10.2003 (half day, p.m.) ** The number of places available may vary. Please check our Web site to find out the current availabili...

  5. Places available**

    CERN Multimedia

    2003-01-01

    Places are available in the following courses: Hands-on Introduction to Python Programming: 11-13.08.2003(3 days) Introduction to the CERN Engineering Data Management System (EDMS): 26.08.2003 (1 day) The CERN Engineering Data Management System (EDMS) for Engineers: 27.08.2003 (1 day) CLEAN-2002 : Travailler en salle blanche : 4.09.2003 (une demi-journée) AutoCAD 2002 - Level 1: 4, 5, 15, 16.09.2003 (2 x 2 days) AutoCAD Mechanical 6 PowerPack : 17, 18, 25, 26.09.2003 et 2, 3.10.2003 (3 x 2 journées, français) AutoCAD 2002 - niveau 1 : 23, 24, 30.09.2003 et 1.10.2003 (2 x 2 journées) Introduction to the CERN Engineering Data Management System (EDMS): 23.09.2003 (1 day) The CERN Engineering Data Management System (EDMS) for Local Administrators: 24-25.09.2003 (2 days) AutoCAD 2002 - niveau 2 : 8 et 10.10.2003 (2 journées) CLEAN-2002: Working in a Cleanroom: 23.10.2003 (half day, p.m.) ** The number of places available may vary. Please ch...

  6. PLACES AVAILABLE

    CERN Multimedia

    Monique Duval

    2002-01-01

    Places are available in the following courses: LabView Hands-on (bilingue/bilingual - gratuit/free of charge) : 13.9.02 (a.m.) LabView DAQ Hands-on (bilingue/bilingual - gratuit/free of charge) : 13.9.02 (p.m.) AutoCAD 2002 - niveau 1 : 19, 20, 26, 27.9.02 (4 jours) LabView Base 1 : 23 - 25.9.02 (3 jours) LabView DAQ (E) : 26 - 27.9.02 (2 days) AutoCAD Mechanical 6 PowerPack (F) : 30.9, 1, 2, 9, 10, 11.10.02 (6 jours) CLEAN-2002 : Working in a Cleanroom (free of charge) : 10.10.02 (half-day, p.m.) AutoCAD 2002 - niveau 2 : 14 - 15.10.02 (2 jours) AutoCAD 2002 - Level 1 : 17, 18, 24, 25.10.02 (4 days) If you wish to participate in one of these courses, please discuss with your supervisor and apply electronically directly from the course description pages that can be found on the Web at : Technical Training or fill in an 'application for training' form available from your Divisional Secretariat or from your DTO (Divisional Training Of...

  7. PLACES AVAILABLE

    CERN Multimedia

    Technical Training; Tel 74924

    2002-01-01

    Places are available in the following courses: LabView hands-on : 21.01.02 (1/2 journée) LabView DAQ hands-on : 21.01.02 (1/2 journée) FileMaker Pro : 22 - 25.1.02 (4 jours) MS-Project 2000 : 24 & 25.01.02 (2 jours) Introduction au PC et à Windows 2000 au CERN : 29 - 30.1.02 (2 jours) LabView Base 1 : 4 - 6.2.02 (3 jours) LabView DAQ (E) : 7 & 8.02.02 (2 days) Hands-on Object-Oriented Design & Programming with Java : 11 - 13.02.02 (3 days) C++ for Particle Physicists : 11 - 15.3.2002 (6 * 3 hour lectures) Cours sur la migration AutoCAD : AutoCAD : Mise à jour AutoCAD r-14 vers 2002 (2 jours) AutoCAD Mechanical PowerPack 6 basé sur AutoCAD 2002 (5 jours) If you wish to participate in one of these courses, please discuss with your supervisor and apply electronically directly from the course description pages that can be found on the Web at : Technical Training or fill in an 'application for training' form available from your Divisional Secretariat or from your DTO ...

  8. PLACES AVAILABLE

    CERN Multimedia

    TECHNICAL TRAINING; Tel. 74460

    2001-01-01

    Places are available in the following courses: MS-Project 1er niveau : 20 - 23.2.01 (4 matins) Architecture d'automatisme : 20 - 21.2.01 (2 jours) Introduction à PowerPoint : 26.2.01 (1 journée) Programmation TSX Premium 1 (Schneider) : 26.2 - 2.3.01 (5 jours) Premiers pas avec votre PC : 27.2 - 2.3.01 (4 matins) C++ for Particle Physicists : 5 - 9.3.01 (6*3 hour lectures) EXCEL : 6, 7 et 13, 14.3.01 (4 jours) The JAVA programming language level 2 :  12 - 14.3.01 (3 days) Nouveautés de FileMaker :  20 - 23.03.01 (4 matins) If you wish to participate in one of these courses, please discuss with your supervisor and apply electronically directly from the course description pages that can be found on the Web at : http://www.cern.ch/Training/ or fill in an 'application for training' form available from your Divisional Secretariat or from your DTO (Divisional Training Officer). Applications will be accepted in the order of their receipt.

  9. PLACES AVAILABLE

    CERN Multimedia

    Monique Duval

    2002-01-01

    Places are available in the following courses: Habilitation électrique : recyclage HT/BT : 11 - 15.3.2002  (2 * 2 heures) PVSS Basics :  8 - 12.4.02  (5 days) ELEC-2002 : Spring Term :  9, 11, 16, 18, 23, 25, 30.4.02 (7 * 2.5 hours) LabVIEW base 1 : 22 - 24.4.02 (3 jours) LabVIEW DSC (F) 25 & 26.4.02 (2 jours) LabVIEW Basics 2 : 13 & 14.5.02 (2 days) LabVIEW DAQ (F) : 15 & 16.5.02 (2 jours) Cours sur la migration AutoCAD :   AutoCAD : Mise à jour AutoCAD r-14 vers 2002 (2 jours) AutoCAD Mechanical PowerPack 6 basé sur AutoCAD 2002 (5 jours) If you wish to participate in one of these courses, please discuss with your supervisor and apply electronically directly from the course description pages that can be found on the Web at : Technical Training or fill in an 'application for training' form available from your Divisional Secretariat or from your DTO (Divisional Training Officer). Applica...

  10. PLACES AVAILABLE

    CERN Multimedia

    Monique Duval

    2002-01-01

    Places are available in the following courses: November 2002   Hands-on Object-Oriented Design and Programming with C++:  19 - 21.11.02  (3 days)  December 2002   LabVIEW - DSC (English) :  2 - 3.12.02  (2 days) AutoCAD 2002 - niveau 2 :  2 & 3.12.02  (2 jours) FileMaker (Français) :  2 - 5.12.02  (4 jours) PCAD Schémas - Débutants :  5 & 6.12.02  (2 jours) PCAD PCB - Débutants :  9 - 11.12.02  (3 jours) FrontPage 2000 - level 1:  9 & 10.12.02  (2 days) If you wish to participate in one of these courses, please discuss with your supervisor and apply electronically directly from the course description pages that can be found on the Web at : Technical Training or fill in an 'application for training' form available from your Divisional Secretariat or from your DTO (Divisiona...

  11. PLACES AVAILABLE

    CERN Multimedia

    Monique Duval

    2002-01-01

    Places are available in the following courses: November 2002   Java Programming Language level 1 :  28 & 29.11.02  (2 days) December 2002   LabVIEW - DSC (English) :  2 - 3.12.02  (2 days) FileMaker (Français) :  2 - 5.12.02  (4 jours) PCAD Schémas - Débutants :  5 & 6.12.02  (2 jours) PCAD PCB - Débutants :  9 - 11.12.02  (3 jours) FrontPage 2000 - level 1:  9 & 10.12.02  (2 days) If you wish to participate in one of these courses, please discuss with your supervisor and apply electronically directly from the course description pages that can be found on the Web at : Technical Training or fill in an 'application for training' form available from your Divisional Secretariat or from your DTO (Divisional Training Officer). Applications will be accepted in the order of their receipt. Technical Training M...

  12. Avaliação da apresentação comercial de escovas dentais disponíveis no Brasil = Evaluation of commercial characteristics of toothbrushes available in Brazil

    Directory of Open Access Journals (Sweden)

    Feitosa, Natália Bueno

    2008-01-01

    Full Text Available Objetivo: A proposta deste estudo foi avaliar a apresentação comercial de 15 escovas dentais destinadas ao público infantil. Metodologia: As escovas foram adquiridas em diferentes pontos de venda na cidade de Belo Horizonte, MG. Foram avaliados: fabricante, dureza das cerdas, instruções sobre o uso do produto, indicação de idade, tempo de uso, desenhos de personagens infantis, selo da Associação Brasileira de Odontologia (ABO, preço, material utilizado no cabo, comprimento das cerdas (mm e presença de corante nas cerdas. Resultados: Um total de 87% das escovas informava sobre a necessidade de troca a cada 3 meses, 73% instruíam sobre uso, 47% possuíam o selo da ABO, 60% apresentavam desenhos infantis e 73% possuíam cerdas de 10 mm de comprimento. O preço variou entre R$1,00 a R$8,55. Conclusão: Os fabricantes utilizaram estratégias publicitárias para atrair as crianças e motivar o consumo, mas muitas escovas não apresentaram informações importantes como selo da ABO, instruções de uso, tempo de uso e idade indicada. O reforço e a orientação do dentista são fundamentais para motivar o paciente sobre a higiene bucal adequada

  13. TV Commercials as Achievement Scripts for Women.

    Science.gov (United States)

    Geis, F. L.; And Others

    1984-01-01

    Women who viewed four current, sex-stereotyped commercials emphasized homemaking over other achievement concerns in imagining their lives 10 years hence. Women who saw same commercials with sex roles reversed put significantly greater emphasis on their own achievement aspirations. Their more equal weighting of home and career matched men's. (CMG)

  14. A new low-cost negative-pressure wound therapy versus a commercially available therapy device widely used to treat complex traumatic injuries: a prospective, randomized, non-inferiority trial

    Directory of Open Access Journals (Sweden)

    Fabio Kamamoto

    Full Text Available OBJECTIVES: Negative-pressure wound therapy has been widely adopted to reduce the complexity of treating a broad range of acute and chronic wounds. However, its cost is high. The objective of this study was to evaluate the following two different methods of negative-pressure wound therapy in terms of healing time: a low-cost method of negative-pressure wound therapy (a pressure stabilizer device connected to a hospital wall-vacuum system with a gauze-sealed dressing, USP and the standard of care (vacuum-assisted closure, VAC. METHODS: This is a randomized, controlled, non-inferiority, unblinded trial. Patients admitted with complex injuries to a trauma center in a public referral hospital who were indicated for orthopedic surgery were randomized to a USP or VAC group. The primary outcome was the time required to achieve a “ready for surgery condition”, which was defined as a wound bed with healthy granulation tissue and without necrosis or purulent secretion. Wound bed area contraction, granulation tissue growth and the direct costs of the dressings were secondary outcomes. RESULTS: Variation in area and granulation tissue growth were essentially the same between the systems, and healing time was equal between the groups (p=0.379. In both systems, serial debridement increased wound area (p=0.934, and granulation tissue was also increased (p=0.408. The mean treatment cost was US$ 15.15 in the USP group and US$ 872.59 in the VAC group. CONCLUSIONS: For treating complex traumatic injuries, USP was non-inferior to and less expensive than VAC.

  15. Places available **

    CERN Multimedia

    2003-01-01

    Places are available in the following courses: PIPES-2003 - Pratique du Sertissage de tubes métalliques et multicouches : 26.8.03 (stage pratique) The CERN Engineering Data Management System (EDMS) for Engineers : 27.8.03 (1 day, free of charge) CLEAN-2002 : Travailler en salle blanche : 4.9.03 (une demi-journée, séminaire gratuit) The CERN Engineering Data Management System (EDMS) for Local Administrators : 24 & 25.9.03 (2 days, free of charge) Siemens SIMATIC Training : Programmation STEP7 - niveau 1 : 29 - 2.10.03 (4 jours) - ouverture des inscriptions fin août Programmation STEP7 - niveau 2 : 13 - 17.10.03 (5 jours) - ouverture des inscriptions fin août Réseau Simatic Net : 22 & 23.10.03 (2 jours) - ouverture des inscriptions fin août CLEAN-2002 : Working in a Cleanroom : 23.20.03 (half day, free of charge) These courses will be given in French or Englis...

  16. Places available**

    CERN Document Server

    2003-01-01

    Places are available in the following courses : FrontPage 2000 - niveau 1: 20 & 21.5.03 (2 jours) PIPES-2003 : Pratique du sertissage de tubes métalliques et multicouches: 21.5.03 (1 jour) Introduction à la CAO Cadence: de la saisie de schéma Concept-HDL au PCB : 20 & 22.5.03 (2 jours) AutoCAD Mechanical 6 PowerPack (E): 5, 6, 12, 13, 26, 27.6.03 (6 days) EXCEL 2000 - niveau 1: 10 & 11.6.03 (2 jours) Conception de PCB rapides dans le flot Cadence: 11.6.03 (matin) EXCEL 2000 - level 1: 12 & 13.6.03 (2 days) Introduction to PVSS: 16.6.03 (half-day, pm) Basic PVSS: 17 - 19.6.03 (3 days) Réalisation de PCB rapides dans le flot Cadence: 17.6.03 (matin) LabView DSC (language to be defined): 19 & 20.6.03 PVSS - JCOP Framework Tutorial: 20.6.03 (1 day) EXCEL 2000 - niveau 2: 24 & 25.6.03 (2 jours) Siemens SIMATIC Training: Introduction to STEP7: 3 & 4.6.03 (2 days) STEP7 Programming: 16 - 20.6.03 (5 days) Simatic Net Network: 26 & 27.6.03 (2 days) These courses will be given...

  17. PLACES AVAILABLE

    CERN Multimedia

    Monique Duval

    2002-01-01

    Places are available in the following courses: Introduction to Oracle 8i : SQL and PL/SQL:  7 - 11.10.02  (5 days) CLEAN-2002 : Working in a Cleanroom (free of charge):  10.10.02  (half-day, p.m.) AutoCAD 2002 - niveau 2 :  14 - 15.10.02  (2 jours) Introduction à DesignSpace :  16.10.02  (1 journée) Introduction to DesignSpace:  17.10.02  (1 day) AutoCAD 2002 - Level 1:  17, 18, 24, 25.10.02  (4 days) AutoCAD Mechanical 6 PowerPack (F) :  21, 22, 23.10 et 4, 5, 6.11.02  (6 jours) Introduction à ANSYS/Introduction to ANSYS (langue à définir suivant demande/ Language to be chosen according to demand):  21 - 25.10.02  (5 jours/days) HREF-2002: Helium Refrigeration Techniques (English-French, bilingual) :  21 - 25.10.2002  (7 half days) HREF-2002: Techniques de la Réfri...

  18. Places available**

    CERN Document Server

    2003-01-01

    Places are available in the following courses : The CERN EDMS for Local Administrators : 24 & 25.9.03 (2 days, free of charge) HeREF-2003 : Techniques de la réfrigération Hélium (cours en français avec support en anglais) : 6 - 10.10.2003 (7 demi-journées) The Java Programming Language Level 1 : 6 - 7.10.2003 (2 days) Java 2 Enterprise Edition - Part 2 : Enterprise JavaBeans : 8 - 10.10.2003 (3 days) FileMaker - niveau 1 : 9 & 10.10.03 (2 jours) EXCEL 2000 - niveau 1 : 20 & 22.10.03 (2 jours) AutoCAD 2002 - niveau 1 : 20, 21, 27, 28.10.03 (4 jours) CLEAN-2002 : Working in a Cleanroom : 23.10.03 (half day, free of charge) AutoCAD 2002 - Level 1 : 3, 4, 12, 13.11.03 (4 days) AutoCAD 2002 - niveau 2 : 10 & 11.11.03 (2 jours) ACCESS 2000 - niveau 1 : 13 & 14.11.03 (2 jours) AutoCAD Mechanical 6 PowerPack (E) : 17, 18, 24, 25.11 & 1, 2.12.03 (6...

  19. PLACES AVAILABLE

    CERN Multimedia

    Monique Duval

    2002-01-01

    Places are available in the following courses: Introduction à DesignSpace :  16.10.02  (1 journée) AutoCAD Mechanical 6 PowerPack (F) :  21, 22, 23.10 et 4, 5, 6.11.02  (6 jours) Introduction à ANSYS 21 - 25.10.02  (5 jours/days) HREF-2002: Helium Refrigeration Techniques (English-French, bilingual) :  21 - 25.10.2002  (7 half days) LabVIEW Basics 1 (English):  21 - 23.10.02  (3 days) LabVIEW Basics 2 (English):  24 & 25.10.02  (2 days) Oracle 8i : Access the Database with Java:  7 & 8.11.02  (2 days) AutoCAD 2002 - niveau 2 :  7 & 8.11.02  (2 jours) AutoCAD 2002 - Level 1:  14, 15, 21, 22.11.02  (4 days) LabVIEW - Advanced (English) :  18 - 20.11.2002  (3 days) AutoCAD 2002 - niveau 1 :  19, 20, 25, 26.11.02 (4 jours) Oracle iDS Designer: First Class:&...

  20. Places available**

    CERN Document Server

    2003-01-01

    Places are available in the following courses: CLEAN-2002 : Travailler en salle blanche (séminaire gratuit) : 4.9.03 (une demi-journée) The CERN EDMS for Local Administrators (free of charge) : 24 & 25.9.03 (2 days) HeREF-2003 : Techniques de la réfrigération Hélium (cours en français avec support en anglais) : 6 - 10.10.2003 (7 demi-journées) The Java Programming Language Level 1 : 6 - 7.10.2003 (2 days) Java 2 Enterprise Edition - Part 2 : Enterprise JavaBeans : 8 - 10.10.2003 (3 days) FileMaker - niveau 1 : 9 & 10.10.03 (2 jours) EXCEL 2000 - niveau 1 : 20 & 22.10.03 (2 jours) AutoCAD 2002 - niveau 1 : 20, 21, 27, 28.10.03 (4 jours) CLEAN-2002 : Working in a Cleanroom (free of charge) : 23.10.03 (half day) AutoCAD Mechanical 6 PowerPack (E) : 23, 24, 30, 31.10 & 12, 13.11.03 (6 days) AutoCAD 2002 - niveau 2 : 10 & 11.11.03 (2 jours)...

  1. Places available**

    CERN Multimedia

    2003-01-01

    Places are available in the following courses: The CERN EDMS for Local Administrators : 24 & 25.9.03 (2 days, free of charge) HeREF-2003 : Techniques de la réfrigération Hélium cours en français avec support en anglais) : 6 - 10.10.2003 (7 demi-journées) The Java Programming Language Level 1 : 6 - 7.10.2003 (2 days) Java 2 Enterprise Edition - Part 2 : Enterprise JavaBeans : 8 - 10.10.2003 (3 days) FileMaker - niveau 1 : 9 & 10.10.03 (2 jours) EXCEL 2000 - niveau 1 : 20 & 22.10.03 (2 jours) AutoCAD 2002 - niveau 1 : 20, 21, 27, 28.10.03 (4 jours) CLEAN-2002 : Working in a Cleanroom : 23.10.03 (half day, free of charge) AutoCAD 2002 - Level 1 : 3, 4, 12, 13.11.03 (4 days) AutoCAD 2002 - niveau 2 : 10 & 11.11.03 (2 jours) ACCESS 2000 - niveau 1 : 13 & 14.11.03 (2 jours) AutoCAD Mechanical 6 PowerPack (E) : 17, 18, 24, 25.11 & 1, 2.12.03 (6 days) FrontPage 2000 - niveau 1 : 20 & 21.11.03 (2 jours) MAGNE-03 : Magnétisme pour l'électrotechnique : 25 - 27.11.03 (3 jours) ...

  2. PLACES AVAILABLE

    CERN Multimedia

    Monique Duval

    2002-01-01

    Places are available in the following courses: LabView hands-on (bilingue/bilingual): 5.11.02 (matin/morning) LabView DAQ hands-on (bilingue/bilingual):  5.11.02  (après-midi afternoon) Introduction au PC et Windows 2000 au CERN:  6 & 7.11.02  (2 jours) Oracle 8i : Access the Database with Java:  7 & 8.11.02  (2 days) AutoCAD 2002 - niveau 2:  7 & 8.11.02  (2 jours) Introduction to PVSS (free of charge):  11.11.2002 pm  (1/2 day) Basic PVSS:  12 - 14.11.02  (3 days) EXCEL 2000 - niveau 1:  12 & 13.11.02  (2 jours) CLEAN-2002: Working in a Cleanroom (English, free of charge):  13.11.2002  (afternoon) LabView Base 1 :  13 - 15.11.02  (3 jours) AutoCAD 2002 - Level 1:  14, 15, 21, 22.11.2002  (4 days) LabVIEW - Advanced:  18 - 20.11.02  (3 days) Auto...

  3. Places available**

    CERN Multimedia

    2003-01-01

    Places are available in the following courses: PIPES-2003 - Pratique du sertissage de tubes métalliques et multicouches :26.8.03(stage pratique) The CERN EDMS for Engineers (free of charge) : 27.8.03 (1 day) CLEAN-2002 : Travailler en salle blanche (séminaire gratuit) : 4.9.03(une demi-journée) The CERN EDMS for Local Administrators (free of charge) : 24 & 25.9.03 (2 days) HeREF-2003 : Techniques de la réfrigération Hélium (cours en français avec support en anglais) : 6 - 10.10.2003 (7 demi-journées) The Java Programming Language Level 1 : 6 - 7.10.2003 (2 days) Java 2 Enterprise Edition - Part 2 : Enterprise JavaBeans : 8 - 10.10.2003 (3 days) FileMaker - niveau 1 : 9 & 10.10.03 (2 jours) EXCEL 2000 - niveau 1 : 20 & 22.10.03 (2 jours) AutoCAD 2002 - niveau 1 : 20, 21, 27, 28.10.03 (4 jours) CLEAN-2002 : Working in a Cleanroom (free of charge) : 23.10.03 (half day) AutoCAD Mechanical 6 PowerPack (E) : 23, 24, 30, 31.10 & 12, 13.11.03 (6 days) AutoCAD 2002 - niveau 2...

  4. Places available**

    CERN Multimedia

    2003-01-01

    Places are available in the following courses: The CERN EDMS for Local Administrators (free of charge) : 24 & 25.9.03 (2 days) HeREF-2003 : Techniques de la réfrigération Hélium (cours en français avec support en anglais) : 6 - 10.10.2003 (7 demi-journées) The Java Programming Language Level 1 : 6 - 7.10.2003 (2 days) Java 2 Enterprise Edition - Part 2 : Enterprise JavaBeans : 8 - 10.10.2003 (3 days) FileMaker - niveau 1 : 9 & 10.10.03 (2 jours) EXCEL 2000 - niveau 1 : 20 & 22.10.03 (2 jours) AutoCAD 2002 - niveau 1 : 20, 21, 27, 28.10.03 (4 jours) CLEAN-2002 : Working in a Cleanroom (free of charge) : 23.10.03 (half day) AutoCAD Mechanical 6 PowerPack (E) : 23, 24, 30, 31.10 & 12, 13.11.03 (6 days) AutoCAD 2002 - niveau 2 : 10 & 11.11.03 (2 jours) ACCESS 2000 - niveau 1 : 13 & 14.11.03 (2 jours) FrontPage 2000 - niveau 1 : 20...

  5. PLACES AVAILABLE

    CERN Multimedia

    Monique Duval

    2002-01-01

    Places are available in the following courses: October 2002   Introduction to the CERN Engineering Data Management System (free of charge):  29.10.2002  (1 day) The CERN EDMS for Advanced users (free of charge):  30.10.2002  (1 day) November 2002   LabView hands-on (bilingue/bilingual): 5.11.02 (matin/morning) LabView DAQ hands-on (bilingue/bilingual):  5.11.02  (après-midi afternoon) Introduction au PC et Windows 2000 au CERN :  6 & 7.11.02  (2 jours) Oracle 8i : Access the Database with Java:  7 & 8.11.02  (2 days) AutoCAD 2002 - niveau 2 :  7 & 8.11.02  (2 jours) Introduction to PVSS (free of charge):  11.11.2002 pm  (1/2 day) Basic PVSS:  12 - 14.11.02  (3 days) EXCEL 2000 - niveau 1 :  12 & 13.11.02  (2 jours) CLEAN-2002: Working in a Cleanroom (English, free ...

  6. PLACES AVAILABLE

    CERN Multimedia

    Monique Duval

    2002-01-01

    Places are available in the following courses: Introduction to Oracle 8i : SQL and PL/SQL:  7 - 11.10.02  (5 days) CLEAN-2002 : Working in a Cleanroom (free of charge):  10.10.02  (half-day, p.m.) LabView Hands-on (bilingue/bilingual) : 10.10.02 (matin/morning) LabView DAQ Hands-on (bilingue/bilingual)  10.10.02 (après-midi /afternoon) Introduction à DesignSpace :  16.10.02  (1 journée) Introduction to DesignSpace:  17.10.02  (1 day) AutoCAD Mechanical 6 PowerPack (F) :  21, 22, 23.10 et 4, 5, 6.11.02  (6 jours) Introduction à ANSYS/Introduction to ANSYS (langue à définir suivant demande/ Language to be chosen according to demand):  21 - 25.10.02  (5 jours/days) HREF-2002: Helium Refrigeration Techniques (English-French, bilingual) :  21 - 25.10.2002  (7 half days) HREF-2002: Techniques de la...

  7. PLACES AVAILABLE

    CERN Multimedia

    Enseignement Technique; Tél. 74924; Technical Training; Monique Duval; Tel. 74924

    2000-01-01

    Places are available in the following courses : Premiers pas avec votre PC 12 - 15.9.00 (4 demi-journées) WORD 20, 21 et 26, 27.9.2000 (4 jours) JAVA programming level 1 25 - 26.9.2000 (2 days) Gaz inflammables 1 26.9.2000 (1 journée) Advanced aspects of PERL 5 6.10.2000 (1 day) Initiation au WWW 10 - 12.10.00 (3 demi-journées) WORD : importer et manipuler des images 16.10.2000 (1 journée) FileMaker 17, 18 et 24, 25.10.00 (4 jours) Nouveautés de WORD 19 et 20.10.2000 (2 jours) ACCESS 1er niveau 30 - 31.10.00 (2 jours)Introduction à PowerPoint 6.11.00 (1 journée)Nouveautés d’EXCEL 7.11.2000(4 demi-journées)Excel 13, 14 et 20, 21.11.00 (4 jours) LabView hands-on 13.11.2000(4 hours)LabView Basics 1 14 - 16.11.2000 (3 days) MS-Project 1er niveau 14-17.11.00 (4 demi-journées) If you wish to participate in one of these courses, please discuss with your supervisor and apply elec...

  8. PLACES AVAILABLE

    CERN Multimedia

    Technical Training; Tel. 74924

    2002-01-01

    Places are available in the following courses: LabView hands-on : 21.01.02 (1/2 journée) LabView DAQ hands-on : 21.01.02 (1/2 journée) FileMaker Pro : 22 - 25.1.02 (4 jours) MS-Project 2000 : 22, 24 & 25.01.02 (3 jours) Introduction au PC et à Windows 2000 au CERN : 29 - 30.1.02 (2 jours) LabView Base 1 : 4 - 6.2.02 (3 jours) LabView DAQ  (E) :  7 & 8.02.02 (2 days) Hands-on Object-Oriented Design & Programming with Java :  11 - 13.02.02 (3 days) PVSS basics :  11 - 15.2.02 (5 days) Introduction à Windows 2000 : 18.2.02 (1 demi-journée) Introduction to the CERN Engineering Data Management System :  20.2.02 (1 day) The CERN Engineering Data Management System for Advanced users :  21.2.02  (1 day) C++ for Particle Physicists :  11 - 15.3.2002  (6 * 3 hour lectures) Cours sur la migration AutoCAD : AutoCAD : Mise à...

  9. PLACES AVAILABLE

    CERN Multimedia

    Technical Training; Tel. 74924

    2001-01-01

    Places are available in the following courses: LabVIEW - Basics 1 :  10 - 12.12.01 (3 days) Introduction to XML :  12 & 13.12.01 (2 days) Introduction au PC et Windows 2000 : 12 & 14.12.01 (2 jours) LabVIEW - Basics 2 :  13 - 14.12.01 (2 days) Habilitation électrique : superviseurs : 17.12.2001 (1/2 journée) MS-Project 2000 : 10 & 11.01.02 (2 jours) EXCEL 2000 - niveau 2 : 15 - 16.1.02 (2 jours) Sécurité dans les installations cryogéniques: 15-17.1.2002 (2 demi-journées) C++ Programming Level 2 - Traps and Pitfalls :  15 - 18.1.2002  (4 days) ELEC-2002 Winter Term: Readout and system electronics for Physics  15.1.2002 - 7.2.2002 (8 half- days) Nouveautés de WORD 2000 : 18.1.02 (1/2 journée) LabView hands-on : 21.01.02 (1/2 journée) LabView DAQ hands-on : 21.01.02 (1/2 journée) FileMaker Pro : 22 -...

  10. PLACES AVAILABLE

    CERN Multimedia

    Enseignement Technique; Tel. 74924

    2001-01-01

    Places are available in the following courses: MS-Project 2000 : 10 & 11.01.02 (2 jours) EXCEL 2000 - niveau 2 : 15 - 16.1.02 (2 jours) Sécurité dans les installations cryogéniques: 15-17.1.2002 (2 demi-journées) C++ Programming Level 2 - Traps and Pitfalls :  15 - 18.1.2002  (4 days) ELEC-2002 Winter Term: Readout and system electronics for Physics  15.1.2002 - 7.2.2002 (8 half- days) Nouveautés de WORD 2000 : 18.1.02 (1/2 journée) LabView hands-on : 21.01.02 (1/2 journée) LabView DAQ hands-on : 21.01.02 (1/2 journée) FileMaker Pro : 22 - 25.1.02 (4 jours) MS-Project 2000 : 24 & 25.01.02 (2 jours) Introduction au PC et à Windows 2000 au CERN : 29 - 30.1.02 (2 jours) LabView Base 1 : 4 - 6.2.02 (3 jours) LabView DAQ  (E) :  7 & 8.02.02 (2 days) Hands-on Object-Oriented Design & Programming with Java :&nbs...

  11. Places available **

    CERN Multimedia

    2003-01-01

    Des places sont disponibles dans les cours suivants : Places are available in the following courses : WorldFIP 2003 pour utilisateurs : 11-14.2.03 (4 jours) DISP-2003 ? Spring I Term : Introduction to Digital Signal Processing : 20, 27.2, 6, 13, 20, 27.3, 3.4.03 (7 X 2-hour lectures) AXEL-2003 - Introduction to Accelerators : 24-28.2.03 (10 X 1-hour lectures) AutoCAD 2002 - niveau 1 : 24, 25.2 & 3, 4.3.03 (4 jours) Introduction à Windows 2000 au CERN : 25.2.03 (1/2 journée) LabView base 2/LabView Basics 2 : 10 & 11.3.03 (2 jours/2 days) langue à définir/Language to be decided C++ for Particle Physicists : 10 ? 14.3.03 (6 X 3-hour lectures) Introduction to PVSS : 10.3.03 (half day, afternoon) Basic PVSS : 11 - 13.3.03 (3 days) LabView avancé /LabView Advanced : 12 - 14.3.03 (3 jours/3days) Langue à définir/language to be decided AutoCAD Mechanical 6 PowerPack (F) : 12, 13, 17, 18, 24 & 25.3.03 (6 jours) PVSS - JCOP Framework Tutorial : 14.3.03 (1 day) MAGNE-03 - Magnetism for Technical Ele...

  12. Places available **

    CERN Multimedia

    2003-01-01

    Des places sont disponibles dans les cours suivants : Places are available in the following courses : Introduction à Windows 2000 au CERN : 25.2.03 (1/2 journée) LabView base 2/LabView Basics 2 : 10 & 11.3.03 (2 jours/2 days) langue à définir/Language to be decided C++ for Particle Physicists : 10 - 14.3.03 (6 X 3-hour lectures) Introduction to PVSS : 10.3.03 (half day, afternoon) Basic PVSS : 11 - 13.3.03 (3 days) LabView avancé /LabView Advanced : 12 - 14.3.03 (3 jours/3days) Langue à définir/Language to be decided AutoCAD Mechanical 6 PowerPack (F) : 12, 13, 17, 18, 24 & 25.3.03 (6 jours) PVSS - JCOP Framework Tutorial : 14.3.03 (1 day) CLEAN-2002 : Working in a cleanroom : 2.4.03 (half-day, afternoon, free course, registration required) LabView base 1/LabView Basics 1 : 9 - 11.4.03 (3 jours/3 days) Langue à définir/Language to be decided DISP-2003 - Spring II Term : Advanced Digital Signal Processing : 30.4, 7, 14, 21.5.03 (4 X 2-hour lectures) AutoCAD 2002 - niveau 2 : 5 & 6.5.03 (...

  13. Places available**

    CERN Multimedia

    2003-01-01

    Places are available in the following courses : CLEAN-2002 : Working in a cleanroom (free course, registration required) : 2.4.03 (half-day, afternoon) LabView base 1/LabView Basics 1 (Langue à définir/ language to be decided) : 9 - 11.4.03 (3 jours/3 days) DISP-2003 - Spring II Term : Advanced Digital Signal Processing : 30.4, 7, 14, 21.5.03 (4 X 2-hour lectures) AutoCAD 2002 - niveau 1 : 29, 30.4 et 7, 8.5.03 (4 jours) AutoCAD 2002 - niveau 2 : 5 & 6.5.03 (2 jours) AutoCAD Mechanical 6 PowerPack (F) : 12, 13, 20, 21, 27 & 28.5.03(6 jours) Formation Siemens SIMATIC /Siemens SIMATIC Training : Introduction à STEP7 /Introduction to STEP7 : 3 & 4.6.03 (2 jours/2 days) Programmation STEP7/STEP7 Programming : 31.3 - 4.4.03 / 16 - 20.6.03 (5 jours/5 days) Réseau Simatic Net /Simatic Net Network : 15 & 16.4.03 / 26 & 27.6.03 These courses will be given in French or English following the requests. Cours de sécurité : Etre TSO au CERN : 3 sessions sont programmées pour 2003 : 25...

  14. Places available **

    CERN Multimedia

    2003-01-01

    Places are available in the following courses : CLEAN-2002 : Working in a cleanroom (free course, registration required): 11.4.03 (half-day, afternoon, ) LabView Basics 2 : 10 - 11.4.03 (3 days) DISP-2003 - Spring II Term : Advanced Digital Signal Processing : 30.4, 7, 14, 21.5.03 (4 X 2-hour lectures) AutoCAD 2002 - niveau 1 : 29, 30.4 et 7, 8.5.03 (4 jours) Oracle iDS Reports : Build Internet Reports : 5 - 9.5.03 (5 days) AutoCAD 2002 - niveau 2 : 5 & 6.5.03 (2 jours) AutoCAD Mechanical 6 PowerPack (F) : 12, 13, 20, 21, 27 & 28.5.03 (6 jours) Formation Siemens SIMATIC /Siemens SIMATIC Training : Introduction à STEP7 /Introduction to STEP7 : 3 & 4.6.03 (2 jours/2 days) Programmation STEP7/STEP7 Programming : 31.3 - 4.4.03 / 16 - 20.6.03 (5 jours/5 days) Réseau Simatic Net /Simatic Net Network : 15 & 16.4.03 / 26 & 27.6.03 These courses will be given in French or English following the requests. Cours de sécurité : Etre TSO au CERN : Prochaines sessions : 24, 25 & 27.6....

  15. Places available**

    CERN Multimedia

    2003-01-01

    Places are available in the following courses : DISP-2003 - Spring II Term : Advanced Digital Signal Processing : 30.4, 7, 14, 21.5.03 (4 X 2-hour lectures) Oracle iDS Reports : Build Internet Reports : 5 - 9.5.03 (5 days) LabView DAQ (language to be defined) : 8 & 9.5.03 AutoCAD Mechanical 6 PowerPack (F) : 12, 13, 20, 21, 27 & 28.5.03 (6 jours) AutoCAD 2002 - niveau 2 : 3 & 4.6.03 (2 jours) LabView DSC (language to be defined) : 19 & 20.6.03 Siemens SIMATIC Training : Introduction to STEP7 : 3 & 4.6.03 (2 days) STEP7 Programming : 16 - 20.6.03 (5 days) Simatic Net Network : 15 & 16.4.03 / 26 & 27.6.03 (sessions of 2 days) These courses will be given in French or English following the requests. Cours de sécurité : Etre TSO au CERN : Prochaines sessions : 24, 25 & 27.6.03 - 4, 5 & 7.11.03 (session de 3 jours) If you wish to participate in one of these courses, please discuss with your supervisor and apply electronically directly from the course description ...

  16. Places available**

    CERN Multimedia

    2003-01-01

    Places are available in the following courses : CLEAN-2002 : Working in a cleanroom (free course, registration required): 11.4.03 (half-day, afternoon, ) LabView Basics 2 : 10 - 11.4.03 (3 days) DISP-2003 - Spring II Term : Advanced Digital Signal Processing : 30.4, 7, 14, 21.5.03 (4 X 2-hour lectures) AutoCAD 2002 - niveau 1 : 29, 30.4 et 7, 8.5.03 (4 jours) Oracle iDS Reports : Build Internet Reports : 5 - 9.5.03 (5 days) AutoCAD 2002 - niveau 2 : 5 & 6.5.03 (2 jours) AutoCAD Mechanical 6 PowerPack (F) : 12, 13, 20, 21, 27 & 28.5.03(6 jours) Formation Siemens SIMATIC /Siemens SIMATIC Training : Introduction à STEP7 /Introduction to STEP7 : 3 & 4.6.03 (2 jours/2 days) Programmation STEP7/STEP7 Programming : 31.3 - 4.4.03 / 16 - 20.6.03 (5 jours/5 days) Réseau Simatic Net /Simatic Net Network : 15 & 16.4.03 / 26 & 27.6.03 These courses will be given in French or English following the requests. Cours de sécurité : Etre TSO au CERN : Prochaines sessions : 24, 25 & 27.6...

  17. Places available**

    CERN Multimedia

    2003-01-01

    Places are available in the following courses : DISP-2003 - Spring II Term : Advanced Digital Signal Processing : 30.4, 7, 14, 21.5.03 (4 X 2-hour lectures) Programmation de pilotes périphériques : 5 - 8.5.03 (4 jours) Oracle iDS Reports : Build Internet Reports : 5 - 9.5.03 (5 days) LabView DAQ (language to be defined) : 8 & 9.5.03 AutoCAD Mechanical 6 PowerPack (F) : 12, 13, 20, 21, 27 & 28.5.0 (6 jours) FrontPage 2000 - niveau 1 : 20 & 21.5.03 (2 jours) AutoCAD 2002 - niveau 2 : 3 & 4.6.03 (2 jours) EXCEL 2000 - niveau 1 : 10 & 11.6.03 (2 jours) EXCEL 2000 - level 1 : 12 & 13.6.03 (2 days) PowerPoint 2000 (F) : 17 & 18.6.03 (2 jours) FrontPage 2000 - niveau 2 : 19 & 20.6.03 (2 jours) LabView DSC (langue à décider/language to be defined) : 19 & 20.6.03 EXCEL 2000 - niveau 2 : 24 & 25.6.03 (2 jours) Siemens SIMATIC Training : Introduction to STEP7 : 3 & 4.6.03 (2 days) STEP7 Programming : 16 - 20.6.03 (5 days) Simatic Net Network : 26 & 27.6.03 ...

  18. Places available **

    CERN Multimedia

    2003-01-01

    Des places sont disponibles dans les cours suivants : Places are available in the following courses : DISP-2003 - Spring I Term : Introduction to Digital Signal Processing : 20, 27.2, 6, 13, 20, 27.3, 3.4.03 (7 X 2-hour lectures) AXEL-2003 - Introduction to Accelerators : 24 - 28.2.03 (10 X 1-hour lectures) AutoCAD 2002 - niveau 1 : 24, 25.2 & 3, 4.3.03 (4 jours) Introduction à Windows 2000 au CERN : 25.2.03 (1/2 journée) LabView base 2/LabView Basics 2 : 10 & 11.3.03 (2 jours/2 days) langue à définir/Language to be decided C++ for Particle Physicists : 10 - 14.3.03 (6 X 3-hour lectures) Introduction to PVSS : 10.3.03 (half day, afternoon) Basic PVSS : 11 - 13.3.03 (3 days) LabView avancé /LabView Advanced : 12 - 14.3.03 (3 jours/3days) Langue à définir/language to be decided AutoCAD Mechanical 6 PowerPack (F) : 12, 13, 17, 18, 24 & 25.3.03 (6 jours) PVSS - JCOP Framework Tutorial : 14.3.03 (1 day) CLEAN-2002 : Working in a cleanroom : 2.4.03 (half-day, afternoon, free course, regis...

  19. Places available**

    CERN Multimedia

    2003-01-01

    Places are available in the following courses : CLEAN-2002 : Working in a cleanroom (free course, registration required): 11.4.03 (half-day, afternoon) LabView Basics 2 : 10 - 11.4.03 (3 days) DISP-2003 - Spring II Term : Advanced Digital Signal Processing : 30.4, 7, 14, 21.5.03 (4 X 2-hour lectures) AutoCAD 2002 - niveau 1 : 29, 30.4 et 7, 8.5.03 (4 jours) Oracle iDS Reports : Build Internet Reports : 5 - 9.5.03 (5 days) AutoCAD 2002 - niveau 2 : 5 & 6.5.03 (2 jours) AutoCAD Mechanical 6 PowerPack (F) : 12, 13, 20, 21, 27 & 28.5.03(6 jours) Formation Siemens SIMATIC /Siemens SIMATIC Training : Introduction à STEP7 /Introduction to STEP7 : 3 & 4.6.03 (2 jours/2 days) Programmation STEP7/STEP7 Programming : 16 - 20.6.03 (5 jours/5 days) Réseau Simatic Net /Simatic Net Network : 15 & 16.4.03 / 26 & 27.6.03 These courses will be given in French or English following the requests. Cours de sécurité : Etre TSO au CERN : Prochaines sessions : 24, 25 & 27.6.03 - 4, 5 & 7....

  20. Places available **

    CERN Multimedia

    2003-01-01

    Des places sont disponibles dans les cours suivants : Places are available in the following courses : C++ for Particle Physicists : 10 - 14.3.03 (6 X 3-hour lectures) Introduction to PVSS : 10.3.03 (half day, afternoon) Basic PVSS : 11 - 13.3.03 (3 days) PVSS - JCOP Framework Tutorial : 14.3.03 (1 day) CLEAN-2002 : Working in a cleanroom : 2.4.03 (half-day, afternoon, free course, registration required) LabView base 1/LabView Basics 1 : 9 - 11.4.03 (3 jours/3 days) Langue à définir/language to be decided DISP-2003 - Spring II Term : Advanced Digital Signal Processing : 30.4, 7, 14, 21.5.03 (4 X 2-hour lectures) AutoCAD 2002 - niveau 1 : 29, 30.4 et 7, 8.5.03 (4 jours) AutoCAD 2002 - niveau 2 : 5 & 6.5.03 (2 jours) AutoCAD Mechanical 6 PowerPack (F) : 12, 13, 20, 21, 27 & 28.5.03 (6 jours) Formation Siemens SIMATIC /Siemens SIMATIC Training : Introduction à STEP7 /Introduction to STEP7 : 11 & 12.3.03 / 3 & 4.6.03 (2 jours/2 days) Programmation STEP7/STEP7 Programming : 31.3 - 4.4.03 / 16...

  1. Places available**

    CERN Multimedia

    2003-01-01

    Places are available in the following courses : Introduction to PVSS : 10.3.03 (half-day, afternoon) CLEAN-2002 : Working in a cleanroom : 2.4.03 (half-day, afternoon, free course, registration required) LabView Basics 1 : 9 - 11.4.03 (3 days) Language to be decided. DISP-2003 - Spring II Term : Advanced Digital Signal Processing : 30.4, 7, 14, 21.5.03 (4 X 2-hour lectures). AutoCAD 2002 - niveau 1 : 29, 30.4 et 7, 8.5.03 (4 jours) AutoCAD 2002 - niveau 2 : 5 & 6.5.03 (2 jours) AutoCAD Mechanical 6 PowerPack (F) : 12, 13, 20, 21, 27 & 28.5.03 (6 jours) Siemens SIMATIC Training: Introduction to STEP7 : 3 & 4.6.03 (2 days) STEP7 Programming : 31.3 - 4.4.03 / 16 - 20.6.03 (5 days) Simatic Net Network : 15 & 16.4.03 / 26 & 27.6.03 These courses will be given in French or English following the requests. Cours de sécurité: Etre TSO au CERN : 3 sessions sont programmées pour 2003 : 25, 26 & 28.3.03 - 24, 25 & 27.6.03 - 4, 5 & 7.11.03 (sessions de 3 jours) ** The number o...

  2. PLACES AVAILABLE

    CERN Multimedia

    Monique Duval

    2002-01-01

    Places are available in the following courses: November 2002   Introduction to PVSS (free of charge): 11.11.02  (afternoon) EXCEL 2000 - niveau 1 :  12 & 13.11.02  (2 jours) CLEAN-2002: Working in a Cleanroom (English, free of charge):  13.11.2002  (afternoon) AutoCAD 2002 - niveau 1 :  14, 15, 21, 22.11.02  (4 jours) Hands-on Object-Oriented Design and Programming with C++:  19 - 21.11.02  (3 days)  EXCEL 2000 - niveau 2 :  25 & 26.11.02  (2 jours) FrontPage 2000 - niveau 1 :  27 & 28.11.02  (2 jours) December 2002   LabVIEW - DSC (English) :  2 - 3.12.02  (2 days) AutoCAD 2002 - niveau 2 :  2 & 3.12.02  (2 jours) FileMaker (Français) :  2 - 5.12.02  (4 jours) PCAD Schémas - Débutants :  5 & 6.12.02 ...

  3. PLACES AVAILABLE

    CERN Multimedia

    Technical training; Tel. 74924

    2001-01-01

    Places are available in the following courses: PROFIBUS : 25 - 26.9.01 (2 jours) PROFIBUS : 27 - 28.9.01 (2 days) Automates et réseaux de terrain : 3 - 4.10.2001 (2 jours) PCAD Schémas - débutants : 4 - 5.10.01 (2 jours) PCAD PCB - débutants : 8 - 10.10.01 (3 jours) Programmation TSX Premium 1 : 15 - 19.10.01 (5 jours) Programmation TSX Premium 1 : 22 - 26.10.01 (5 jours) Programming TSX Premium 2: 19 - 23.11.01 (5 days) Programmation TSX Premium 2 : 26 - 30.11.01 (5 jours) Autocad Migration support courses: a detailed calendar will be published shortly for this series of sessions which will start on 15.10.2001. Registration is already open AutoCAD : Mise à jour AutoCAD r-14 vers 2002 (2 jours) AutoCAD Mechanical PowerPack 6 basé sur AutoCAD 2002 (5 jours) The following LabView courses will be given in either English or French according to demand LabVIEW - Base 1 / LabVIEW - Basics 1 : 10 - 12.9.01 (3 jours / 3 days)...

  4. PLACES AVAILABLES

    CERN Multimedia

    Technical Training; Tel. 74924

    2001-01-01

    Places are available in the following courses: PVSS Basics : 20 - 24.8.01 (5 days) PROFIBUS : 25 - 26.9.01 (2 jours) PROFIBUS : 27 - 28.9.01 (2 days) PCAD Schémas - débutants : 4 - 5.10.01 (2 jours) PCAD PCB - débutants : 8 - 10.10.01 (3 jours) Programming TSX Premium 1: 15 - 19.10.01 (5 days) Programmation TSX Premium 1 : 22 - 26.10.01 (5 jours) Programming TSX Premium 2: 19 - 23.11.01 (5 days) Programmation TSX Premium 2 : 26 - 30.11.01 (5 jours) The following LabView courses will be given in either English or French according to demand LabVIEW - Base 1 / LabVIEW - Basics 1 : 10 - 12.9.01 (3 jours / 3 days) LabVIEW - DAQ / LabVIEW - DAQ : 13 - 14.9.01 (2 jours / 2 days) LabVIEW - Base 1 / LabVIEW - Basics 1 : 15 - 17.10.01 (3 jours / 3 days) LabVIEW - Base 2 / LabVIEW - Basics 2 : 18 - 19.10.01 (2 jours / 2 days) LabVIEW - Base 1 / LabVIEW - Basics 1 : 12 - 14.11.01 (3 jours / 3 days) LabVIEW - DAQ / LabVIEW - DAQ : 15 - 16.11.01 (2 jours / 2...

  5. PLACES AVAILABLE

    CERN Multimedia

    Monique Duval

    2002-01-01

    Places are available in the following courses: November 2002   LabView hands-on (bilingue/bilingual): 5.11.02 (matin/morning) LabView DAQ hands-on (bilingue/bilingual):  5.11.02  (après-midi afternoon) PCAD Schémas - Débutants :  5 & 6.11.02  (2 jours) PCAD PCB - Débutants :  9 - 11.11.02  (3 jours) Introduction au PC et Windows 2000 au CERN :  6 & 7.11.02  (2 jours) Oracle 8i : Access the Database with Java :  7 & 8.11.02  (2 days) Introduction to PVSS (free of charge):  11.11.2002 pm  (1/2 day) Basic PVSS:  12 - 14.11.02  (3 days) EXCEL 2000 - niveau 1 :  12 & 13.11.02  (2 jours) CLEAN-2002: Working in a Cleanroom (English, free of charge):  13.11.2002  (afternoon) LabView Base 1 :  13 - 15.11.02  (3 jours) AutoCAD 2002 - niveau 1 :  14, 15, 21, 22.11.02  (4 jours) LabVIEW - Advanced:  18 - 20.11.02  (3 days) Hands-on Object-Oriented Design and Programming with C++ :  19 - 21.11.02  (3 days)  LabVIEW - Basics 2:  21 - 22.11.02 ...

  6. Places available**

    CERN Multimedia

    2003-01-01

    Places are available in the following courses : EXCEL 2000 - niveau 1 : 10 & 11.6.03 (2 jours) Conception de PCB rapides dans le flot Cadence : 11.6.03 (matin) EXCEL 2000 - level 1 : 12 & 13.6.03 (2 days) Introduction to PVSS : 16.6.03 (p.m.) Basic PVSS : 17 - 19.6.03 (3 days) Réalisation de PCB rapides dans le flot Cadence : 17.6.03 (matin) PVSS - JCOP Framework Tutorial : 20.6.03 (1 day) EXCEL 2000 - niveau 2 : 24 & 25.6.03 (2 jours) Siemens SIMATIC Training : Introduction to STEP7 : 3 & 4.6.03 (2 jours/2 days) STEP7 Programming : 16 - 20.6.03 (5 jours/5 days) Simatic Net Network : 26 & 27.6.03 (2 jours/2 days) These courses will be given in French or English following the requests. Programmation automate Schneider : Programmation automate Schneider TSX Premium - 1er niveau : 10 - 13.6.03 (4 jours) - audience : toute personne qui veux maitriser la msie en uvre et la programmation d'un automate TSX Premium - objectifs : maitriser la mise en uvre et la programmation d'un autom...

  7. Places available**

    CERN Multimedia

    2003-01-01

    Places are available in the following courses : FrontPage 2000 - niveau 1 : 20 & 21.5.03 (2 jours) PIPES-2003 : Pratique du sertissage de tubes métalliques et multicouches : 21.5.03 (1 jour) Introduction à la CAO Cadence : de la saisie de schéma Concept-HDL au PCB : 20 & 22.5.03 (2 jours) AutoCAD 2002 - niveau 2 : 3 & 4.6.03 (2 jours) AutoCAD Mechanical 6 PowerPack (F) : 5, 6, 12, 13, 26, 27.6.03 (6 jours) EXCEL 2000 - niveau 1 : 10 & 11.6.03 (2 jours) Conception de PCB rapides dans le flot Cadence : 11.6.03 (matin) EXCEL 2000 - level 1 : 12 & 13.6.03 (2 days) PowerPoint 2000 (F) : 17 & 18.6.03 (2 jours) Réalisation de PCB rapides dans le flot Cadence : 17.6.03 (matin) FrontPage 2000 - niveau 2 : 19 & 20.6.03 (2 jours) LabView DSC (langue à décider/language to be defined) : 19 & 20.6.03 EXCEL 2000 - niveau 2 : 24 & 25.6.03 (2 jours) Siemens SIMATIC Training: Introduction to STEP7 : 3 & 4.6.03 (2 days) STEP7 Programming : 16 - 20.6.03 (5 days) Simatic...

  8. PLACES AVAILABLE

    CERN Multimedia

    Technical Training; Tel. 74924

    2001-01-01

    Places are available in the following courses: PVSS Basics : 20 - 24.8.01 (5 days) PROFIBUS : 25 - 26.9.01 (2 jours) PROFIBUS : 27 - 28.9.01 (2 days) PCAD Schémas - débutants : 4 - 5.10.01 (2 jours) PCAD PCB - débutants : 8 - 10.10.01 (3 jours) Programming TSX Premium 1: 15 - 19.10.01 (5 days) Programmation TSX Premium 1 : 22 - 26.10.01 (5 jours) Programming TSX Premium 2: 19 - 23.11.01 (5 days) Programmation TSX Premium 2 : 26 - 30.11.01 (5 jours) The following LabView courses will be given in either English or French according to demand LabVIEW - Base 1 / LabVIEW - Basics 1 : 10 - 12.9.01 (3 jours / 3 days) LabVIEW - DAQ / LabVIEW - DAQ : 13 - 14.9.01 (2 jours / 2 days) LabVIEW - Base 1 / LabVIEW - Basics 1 : 15 - 17.10.01 (3 jours / 3 days) LabVIEW - Base 2 / LabVIEW - Basics 2 : 18 - 19.10.01 (2 jours / 2 days) LabVIEW - Base 1 / LabVIEW - Basics 1 : 12 - 14.11.01 (3 jours / 3 days) LabVIEW - DAQ / LabVIEW - DAQ : 15 - 16.11.01 (2 jours / 2...

  9. PLACES AVAILABLE

    CERN Multimedia

    Technical Training; Tel. 74924

    2001-01-01

    Places are available in the following courses: Introduction à Windows 2000 au CERN : 2 sessions de _ journée les 24 et 25.9.01 PROFIBUS : 25 - 26.9.01 (2 jours) PROFIBUS : 27 - 28.9.01 (2 days) PowerPoint 2000 : 1 et 2.10.01 (2 jours) EXCEL 2000 - niveau 1 : 3 et 4.10.01 (2 jours) Automates et réseaux de terrain : 3 - 4.10.2001 (2 jours) PCAD Schémas - débutants : 4 - 5.10.01 (2 jours) Introduction à Outlook : 5.10.01 (1 journée) Frontpage 2000 - niveau 1 : 8 et 9.10.01 (2 jours) PCAD PCB - débutants : 8 - 10.10.01 (3 jours) C++ for Particle Physicists : 8 - 12.10.01 (6 3-hour lectures) MS-Project 2000 - niveau 1 : 15 - 18.10.01 (4 demi-journées) LabView Basics 1 :  15 - 17.10.01  (3 days) Programmation TSX Premium 1 : 15 - 19.10.01 (5 jours) WORD 2000 : importer et manipuler des images : 19.10.01 (1 journée) Programmation TSX Premium 1 : 22 - 26.10.01...

  10. PLACES AVAILABLE

    CERN Multimedia

    Technical Training; Tel. 74924

    2001-01-01

    Places are available in the following courses: Cadence Board Design tools : Upgrading to release 14 :  3 1-day sessions on 9, 10 & 11.10.01 MS-Project 2000 - niveau 1 : 15 - 18.10.01 (4 demi-journées) LabView Base 2 : 18 & 19.10.01 (2 jours) WORD 2000 : importer et manipuler des images : 19.10.01 (1 journée) Contract Follow-up (F) :  30.10.01 (1/2 journée) The CERN Engineering Data Management System for Electronics Design :  30.10.01 (1 day) UNIX pour non-programmeurs : 5 - 7.11.01 (3 jours) The Java programming language Level 1: 8 - 9.11.01 (2 days) LabView Base 1 : 12 - 14.11.01 (3 jours) Introduction to PERL 5 :  15 - 16.11.01  (2 days) Introduction to XML :  19 - 20.11.01 (2 days) Programming TSX Premium 1 :  19 - 23.11.01  (5 days) Introduction to C Programming :  21- 23.11.01 (3 days) The Java programming language Level 2:  26 - 28.11.01 (...

  11. PLACES AVAILABLE

    CERN Multimedia

    Technical Training; Tel. 74924

    2001-01-01

    Places are available in the following courses: Introduction à Windows 2000 au CERN : 2 sessions de _ journée les 24 et 25.9.01 PROFIBUS : 25 - 26.9.01 (2 jours) PROFIBUS : 27 - 28.9.01 (2 days) EXCEL 2000 - niveau 1 : 3 et 4.10.01 (2 jours) Automates et réseaux de terrain : 3 - 4.10.2001 (2 jours) Introduction à Outlook : 5.10.01 (1 journée) Frontpage 2000 - niveau 1 : 8 et 9.10.01 (2 jours) C++ for Particle Physicists : 8 - 12.10.01 (6 lectures) MS-Project 2000 - niveau 1 : 15 - 18.10.01 (4 demi-journées) Programmation TSX Premium 1 : 15 - 19.10.01 (5 jours) WORD 2000 : importer et manipuler des images : 19.10.01 (1 journée) Programmation TSX Premium 1 : 22 - 26.10.01 (5 jours) UNIX pour non-programmeurs : 5 - 7.11.01 (3 jours) The Java programming language Level 1: 8 - 9.11.01 (2 days) Introduction to PERL 5 :  15 - 16.11.01  (2 days) Introduction to XML :  19 - 20.11.01 (2...

  12. PLACES AVAILABLE

    CERN Multimedia

    Technical Training; Tel. 74924

    2001-01-01

    Places are available in the following courses: EXCEL 2000 - niveau 1 : 3 et 4.10.01 (2 jours) Automates et réseaux de terrain : 3 - 4.10.2001 (2 jours) Introduction à Outlook : 5.10.01 (1 journée) C++ for Particle Physicists : 8 - 12.10.01 (6 lectures) Cadence Board Design tools : Upgrading to release 14 : 3 1-day sessions on 9, 10 & 11.10.01 MS-Project 2000 - niveau 1 : 15 - 18.10.01 (4 demi-journées) LabView Base 2 : 18 & 19.10.01 (2 jours) WORD 2000 : importer et manipuler des images : 19.10.01 (1 journée) The CERN Engineering Data Management System for Electronics Design :  30.10.01 (1 day) UNIX pour non-programmeurs : 5 - 7.11.01 (3 jours) The Java programming language Level 1: 8 - 9.11.01 (2 days) Introduction to PERL 5 :  15 - 16.11.01  (2 days) Introduction to XML :  19 - 20.11.01 (2 days) Programming TSX Premium 1 :  19 - 23.11.01  (5 days) Introd...

  13. PLACES AVAILABLE

    CERN Multimedia

    Technical Training; Tel. 74924

    2001-01-01

    Places are available in the following courses: MS-Project 2000 - niveau 1 : 15 - 18.10.01 (4 demi-journées) LabView Base 2 : 18 & 19.10.01 (2 jours) WORD 2000 : importer et manipuler des images : 19.10.01 (1 journée) Contract Follow-up (F) : 30.10.01 (1/2 journée) The CERN Engineering Data Management System for Electronics Design :  30.10.01 (1 day) UNIX pour non-programmeurs : 5 - 7.11.01 (3 jours) The Java programming language Level 1: 8 - 9.11.01 (2 days) LabView Base 1 : 12 - 14.11.01 (3 jours) Automates et réseaux de terrain : 13 & 14.11.01 (2 jours) Introduction to PERL 5 :  15 - 16.11.01  (2 days) Introduction to XML :  19 - 20.11.01 (2 days) Programming TSX Premium 1 :  19 - 23.11.01  (5 days) Introduction to C Programming :  21- 23.11.01 (3 days) The Java programming language Level 2:  26 - 28.11.01 (3 days) Programmation TSX Premium 2 : 26 ...

  14. PLACES AVAILABLE

    CERN Multimedia

    Monique Duval

    2002-01-01

    Places are available in the following courses: LabView Base 1 :  23 - 25.9.02  (3 jours) Object-Oriented Analysis & Design using UML:  25 - 27.9.02  (3 days) LabView DAQ (E):  26 - 27.9.02  (2 days) Introduction to Oracle 8i : SQL and PL/SQL:  7 - 11.10.02  (5 days) CLEAN-2002 : Working in a Cleanroom (free of charge):  10.10.02  (half-day, p.m.) AutoCAD 2002 - niveau 2 :  14 - 15.10.02  (2 jours) Introduction à DesignSpace :  16.10.02  (1 journée) Introduction to DesignSpace:  17.10.02  (1 day) AutoCAD 2002 - Level 1:  17, 18, 24, 25.10.02  (4 days) AutoCAD Mechanical 6 PowerPack (F) :  21, 22, 23.10 et 4, 5, 6.11.02  (6 jours) Introduction à ANSYS/Introduction to ANSYS (langue à définir suivant demande/ Language to be chosen according to demand):...

  15. PLACES AVAILABLE

    CERN Multimedia

    Monique Duval

    2002-01-01

    Places are available in the following courses: Java 2 Enterprise Edition - Part 2: Enterprise JavaBeans:  18 - 20.9.02  (3 days) AutoCAD 2002 - niveau 1 :  19, 20, 26, 27.9.02  (4 jours) LabView Base 1 :  23 - 25.9.02  (3 jours) Object-Oriented Analysis & Design using UML:  25 - 27.9.02  (3 days) LabView DAQ (E):  26 - 27.9.02  (2 days) Introduction to Oracle 8i : SQL and PL/SQL:  7 - 11.10.02  (5 days) CLEAN-2002 : Working in a Cleanroom (free of charge):  10.10.02  (half-day, p.m.) AutoCAD 2002 - niveau 2 :  14 - 15.10.02  (2 jours) Introduction à DesignSpace :  16.10.02  (1 journée) Introduction to DesignSpace:  17.10.02  (1 day) AutoCAD 2002 - Level 1:  17, 18, 24, 25.10.02  (4 days) AutoCAD Mechanical 6 PowerPack (F) :  21, 22, 23.10 et 4, 5, 6.11....

  16. PLACES AVAILABLE

    CERN Multimedia

    Technical Training; Tel. 74924

    2001-01-01

    Places are available in the following courses: Automates et réseaux de terrain : 13 & 14.11.01 (3 jours) Introduction à Windows 2000 au CERN : 12 - 14.11.01 (1/2 journée) Introduction to Windows 2000 at CERN :  14.11.01  (half-day) Introduction to PERL 5 :  15 - 16.11.01  (2 days) Sécurité dans les installations cryogéniques : 21 - 22.11.2001 (2 demi-journées) Introduction to C Programming :  21- 23.11.01 (3 days) Programmation TSX Premium 2 : 26 - 30.11.01 (5 jours) Contract Follow-up (F) : 26.11.01 (1/2 journée) Object-Oriented Analysis and Design :  27 - 30.11.2001  (4 days) Introduction to the CERN Engineering Data Management System :  30.11.2001 (1 day) Electromagnetic Compatibility (EMC): Introduction (bilingual) :  3.12.01 (half-day) Introduction to the CERN Engineering Data Management System : 07.12.2001...

  17. PLACES AVAILABLE

    CERN Multimedia

    Technical Training; Tel. 74924

    2001-01-01

    Places are available in the following courses: Contract Follow-up (F) : 30.10.01 (1/2 journée) The CERN Engineering Data Management System for Electronics Design :  30.10.01 (1 day) UNIX pour non-programmeurs : 5 - 7.11.01 (3 jours) Nouveautés d'EXCEL : 5.11.01 (1/2 journée) Introduction a Windows 2000 au CERN : 6.11.01 (1/2 journée) The Java programming language Level 1: 8 - 9.11.01 (2 days) LabView Base 1 : 12 - 14.11.01 (3 jours) Automates et réseaux de terrain : 13 & 14.11.01 (2 jours) Introduction to PERL 5 :  15 - 16.11.01  (2 days) Introduction to XML :  19 - 20.11.01 (2 days) Programming TSX Premium 1 :  19 - 23.11.01  (5 days) Introduction to C Programming :  21- 23.11.01 (3 days) The Java programming language Level 2:  26 - 28.11.01 (3 days) Programmation TSX Premium 2 : 26 - 30.11.01 (5 jours) Autocad Migration support courses: a detail...

  18. PLACES AVAILABLE

    CERN Multimedia

    Technical Training; Tel. 74924

    2001-01-01

    Places are available in the following courses: Contract Follow-up (F) : 30.10.01 (1/2 journée) The CERN Engineering Data Management System for Electronics Design :  30.10.01 (1 day) Nouveautés d'Excel 2000 : 5.11.01 (1/2 journée) UNIX pour non-programmeurs : 5 - 7.11.01 (3 jours) Introduction à Windows 2000 au CERN : 6.11.01 (1/2 journée) The Java programming language Level 1: 8 - 9.11.01 (2 days) LabView Base 1 : 12 - 14.11.01 (3 jours) LabVIEW DAQ (F) : 15 & 16.11.01 (2 jours) Automates et réseaux de terrain : 13 & 14.11.01 (2 jours) Introduction to PERL 5 :  15 - 16.11.01  (2 days) LabVIEW - DAQ : 15 - 16.11.01 (2 jours) Introduction to XML :  19 - 20.11.01 (2 days) Introduction to C Programming :  21- 23.11.01 (3 days) Programmation TSX Premium 2 : 26 - 30.11.01 (5 jours) Object-Oriented Analysis and Design :  27 - 30.11.2001 (4 days) Hands...

  19. PLACES AVAILABLE

    CERN Multimedia

    Technical Training; Tel. 74924

    2001-01-01

    Places are available in the following courses: Nouveautés d'EXCEL : 5.11.01 (1/2 journée) Introduction a Windows 2000 au CERN : 6.11.01 (1/2 journée) UNIX pour non-programmeurs : 5 - 7.11.01 (3 jours) Design Patterns :  7 - 8.11.01 (2 days) The Java programming language Level 1: 8 - 9.11.01 (2 days) Automates et réseaux de terrain : 13 & 14.11.01 (3 jours) Introduction à Windows 2000 au CERN : 12 - 14.11.01 (1/2 journée) Introduction to Windows 2000 at CERN :  14.11.01  (half-day) Introduction to PERL 5 :  15 - 16.11.01  (2 days) Introduction to C Programming :  21- 23.11.01 (3 days) Programmation TSX Premium 2 : 26 - 30.11.01 (5 jours) Contract Follow-up (F) : 26.11.01 (1/2 journée) Object-Oriented Analysis and Design :  27 - 30.11.2001  (4 days) Hands-on Object-Oriented Design and Programming with C++ :  11 - 13.12.2...

  20. PLACES AVAILABLE

    CERN Multimedia

    Monique Duval

    2002-01-01

    Places are available in the following courses: ELEC-2002 : Spring Term :  9, 11, 16, 18, 23, 25, 30.4.02 (7 * 2.5 hours) Object-Oriented Analysis & Design: 16 - 19.4.02  (4 days) The CERN Engineering Data Management System for Advanced users:  16.4.02  (1 day) Migration from AutoCAD 14 towards AutoCAD Mechanical6 PowerPack:  17 - 19.4 and 2 &3.5.02  (5 days) AutoCAD - niveau 1 : 22, 23, 29, 30.4 et 6, 7.5.02 (6 jours) LabVIEW base 1 : 22 - 24.4.02 (3 jours) CLEAN 2002 : working in a cleanroom:  24.4.02  (half-day, pm) LabVIEW DSC (F) 25 & 26.4.02 (2 jours) AutoCAD : Mise à jour AutoCAD r-14 vers 2002 : 25 & 26.4.02 (2 jours) Cotations selon les normes GPS de l'ISO : 29 - 30.4.02 (2 jours) Introduction to the CERN Engineering Data Management System:  7.5.02  (1 day) LabVIEW Basics 2 : 13 & 14.5.02 (2 days) AutoCAD Mechanical 6 PowerPack (F) : 13-...