WorldWideScience

Sample records for gravimetric isopiestic apparatus

  1. Phase Behavior of Aqueous NA-K-MG-CA-CI-NO3 Mixtures: Isopiestic Measurements and Thermodynamic Modeling

    Energy Technology Data Exchange (ETDEWEB)

    M.S. Gruszkiewiez; D.A. Palmer; R.D. Springer; P. Wang; A. Anderko

    2006-09-14

    A comprehensive model has been established for calculating thermodynamic properties of multicomponent aqueous systems containing the Na{sup +}, K{sup +}, Mg{sup 2+}, Ca{sup 2+}, Cl{sup -}, and NO{sub 3}{sup -} ions. The thermodynamic framework is based on a previously developed model for mixed-solvent electrolyte solutions. The framework has been designed to reproduce the properties of salt solutions at temperatures ranging from the freezing point to 300 C and concentrations ranging from infinite dilution to the fused salt limit. The model has been parameterized using a combination of an extensive literature database and new isopiestic measurements for thirteen salt mixtures at 140 C. The measurements have been performed using Oak Ridge National Laboratory's (ORNL) previously designed gravimetric isopiestic apparatus, which makes it possible to detect solid phase precipitation. Water activities are reported for mixtures with a fixed ratio of salts as a function of the total apparent salt mole fraction. The isopiestic measurements reported here simultaneously reflect two fundamental properties of the system, i.e., the activity of water as a function of solution concentration and the occurrence of solid-liquid transitions. The thermodynamic model accurately reproduces the new isopiestic data as well as literature data for binary, ternary and higher-order subsystems. Because of its high accuracy in calculating vapor-liquid and solid-liquid equilibria, the model is suitable for studying deliquescence behavior of multicomponent salt systems.

  2. Vapor pressures and isopiestic molalities of concentrated CaCl2(aq), CaBr2(aq), and NaCl(aq) to T = 523 K

    International Nuclear Information System (INIS)

    Gruszkiewicz, Miroslaw S.; Simonson, John M.

    2005-01-01

    The Oak Ridge National Laboratory high-temperature isopiestic apparatus was outfitted with precise pressure gauges to allow for direct vapor pressure measurements. Vapor pressures over concentrated solutions of CaCl 2 (aq), and CaBr 2 (aq) were measured at temperatures between (380.15 and 523.15) K in the range of water activities between 0.2 and 0.85. Isopiestic molalities were used to determine osmotic coefficients at the conditions where NaCl reference standard solutions remained undersaturated. The main goal of this work was to improve the accuracy of isopiestic comparisons based on the calcium chloride reference standard. Osmotic coefficients for CaCl 2 (aq) and CaBr 2 (aq) calculated from both isopiestic and direct vapor pressure results were combined with the literature data and used to build general thermodynamic models based on a variant of extended Pitzer ion-interaction equations and valid at the saturation pressure of water. While these empirical models approach the accuracy of the experimental data in a wider range of concentrations and temperatures than any previously published equations, considerable amounts of accurate data and a substantial effort are required in order to obtain a satisfactory representation using power series-based virial equations. The effect of experimental uncertainties on the accuracy of the direct vapor pressure results is discussed, including in particular the error caused by the presence in the apparatus of a small amount of CO 2 . The substantial decrease of the solubility product of CaCO 3 in concentrated chloride solutions at temperatures above 423 K is a serious defect of calcium chloride as a water activity reference standard

  3. Vapor pressures and isopiestic molalities of concentrated CaCl{sub 2}(aq), CaBr{sub 2}(aq), and NaCl(aq) to T = 523 K

    Energy Technology Data Exchange (ETDEWEB)

    Gruszkiewicz, Miroslaw S. [Oak Ridge National Laboratory, Chemical Sciences Division, P.O. Box 2008, Building 4500S MS-6110, Oak Ridge, TN 37831-6110 (United States)]. E-mail: gruszkiewicz@ornl.gov; Simonson, John M. [Oak Ridge National Laboratory, Chemical Sciences Division, P.O. Box 2008, Building 4500S MS-6110, Oak Ridge, TN 37831-6110 (United States)]. E-mail: simonsonjm@ornl.gov

    2005-09-15

    The Oak Ridge National Laboratory high-temperature isopiestic apparatus was outfitted with precise pressure gauges to allow for direct vapor pressure measurements. Vapor pressures over concentrated solutions of CaCl{sub 2}(aq), and CaBr{sub 2}(aq) were measured at temperatures between (380.15 and 523.15) K in the range of water activities between 0.2 and 0.85. Isopiestic molalities were used to determine osmotic coefficients at the conditions where NaCl reference standard solutions remained undersaturated. The main goal of this work was to improve the accuracy of isopiestic comparisons based on the calcium chloride reference standard. Osmotic coefficients for CaCl{sub 2}(aq) and CaBr{sub 2}(aq) calculated from both isopiestic and direct vapor pressure results were combined with the literature data and used to build general thermodynamic models based on a variant of extended Pitzer ion-interaction equations and valid at the saturation pressure of water. While these empirical models approach the accuracy of the experimental data in a wider range of concentrations and temperatures than any previously published equations, considerable amounts of accurate data and a substantial effort are required in order to obtain a satisfactory representation using power series-based virial equations. The effect of experimental uncertainties on the accuracy of the direct vapor pressure results is discussed, including in particular the error caused by the presence in the apparatus of a small amount of CO{sub 2}. The substantial decrease of the solubility product of CaCO{sub 3} in concentrated chloride solutions at temperatures above 423 K is a serious defect of calcium chloride as a water activity reference standard.

  4. Isopiestic studies of aqueous solutions at elevated temperatures

    International Nuclear Information System (INIS)

    Holmes, H.F.; Mesmer, R.E.

    1981-01-01

    Isopiestic measurements have been made on SrCl 2 (aq) and BaCl 2 (aq) over the temperature range 382.96 to 473.61 K with NaCl(aq) as the reference solution for the calculation of osmotic coefficients. The molalities corresponded to NaCl(aq) molalities ranging from 0.6 to 6.5 mol kg -1 . An ion-interaction model was fitted to the osmotic coefficients of SrCl 2 (aq) and BaCl 2 (aq) with a standard deviation of fit (in the osmotic coefficient) ranging from 0.0007 to 0.0048. Parameters derived from the fit were used to calculate the activity coefficients. The osmotic and activity coefficients decrease with increasing temperature and become less dependent on molality. Previous isopiestic results between 318 and 394 K agree with the present study. Activity coefficients from electrochemical measurements between 283.15 and 343.15 K are not consistent with the isopiestic results. (author)

  5. The error analysis of the determination of the activity coefficients via the isopiestic method

    International Nuclear Information System (INIS)

    Zhou Jun; Chen Qiyuan; Fang Zheng; Liang Yizeng; Liu Shijun; Zhou Yong

    2005-01-01

    Error analysis is very important to experimental designs. The error analysis of the determination of activity coefficients for a binary system via the isopiestic method shows that the error sources include not only the experimental errors of the analyzed molalities and the measured osmotic coefficients, but also the deviation of the regressed values from the experimental data when the regression function is used. It also shows that the accurate chemical analysis of the molality of the test solution is important, and it is preferable to keep the error of the measured osmotic coefficients changeless in all isopiestic experiments including those experiments on the very dilute solutions. The isopiestic experiments on the dilute solutions are very important, and the lowest molality should be low enough so that a theoretical method can be used below the lowest molality. And it is necessary that the isopiestic experiment should be done on the test solutions of lower than 0.1 mol . kg -1 . For most electrolytes solutions, it is usually preferable to require the lowest molality to be less than 0.05 mol . kg -1 . Moreover, the experimental molalities of the test solutions should be firstly arranged by keeping the interval of the logarithms of the molalities nearly constant, and secondly more number of high molalities should be arranged, and we propose to arrange the experimental molalities greater than 1 mol . kg -1 according to some kind of the arithmetical progression of the intervals of the molalities. After experiments, the error of the calculated activity coefficients of the solutes could be calculated from the actually values of the errors of the measured isopiestic molalities and the deviations of the regressed values from the experimental values with our obtained equations

  6. Tandem Gravimetric and Volumetric Apparatus for Methane Sorption Measurements

    Science.gov (United States)

    Burress, Jacob; Bethea, Donald

    Concerns about global climate change have driven the search for alternative fuels. Natural gas (NG, methane) is a cleaner fuel than gasoline and abundantly available due to hydraulic fracturing. One hurdle to the adoption of NG vehicles is the bulky cylindrical storage vessels needed to store the NG at high pressures (3600 psi, 250 bar). The adsorption of methane in microporous materials can store large amounts of methane at low enough pressures for the allowance of conformable, ``flat'' pressure vessels. The measurement of the amount of gas stored in sorbent materials is typically done by measuring pressure differences (volumetric, manometric) or masses (gravimetric). Volumetric instruments of the Sievert type have uncertainties that compound with each additional measurement. Therefore, the highest-pressure measurement has the largest uncertainty. Gravimetric instruments don't have that drawback, but can have issues with buoyancy corrections. An instrument will be presented with which methane adsorption measurements can be performed using both volumetric and gravimetric methods in tandem. The gravimetric method presented has no buoyancy corrections and low uncertainty. Therefore, the gravimetric measurements can be performed throughout an entire isotherm or just at the extrema to verify the results from the volumetric measurements. Results from methane sorption measurements on an activated carbon (MSC-30) and a metal-organic framework (Cu-BTC, HKUST-1, MOF-199) will be shown. New recommendations for calculations of gas uptake and uncertainty measurements will be discussed.

  7. Isopiestic studies of aqueous solutions at elevated temperatures

    International Nuclear Information System (INIS)

    Holmes, H.F.; Mesmer, R.E.

    1981-01-01

    Isopiestic measurements have been made for LiCl(aq) and CsCl(aq) over the temperature range 382.96 to 473.61 K. NcCl(aq) served as the reference electrolyte for the calculation of osmotic coefficients and the molalities ranged from about 0.6 to 6 mol kg -1 , for NaCl(aq). An ion-interaction model gave an excellent fit to the experimental osmotic coefficients with a standard error of fit ranging from 0.0004 to 0.0016 in the osmotic coefficient. Parameters obtained from the fit were used to calculate the activity coefficients. The osmotic and activity coefficients both decreased with increasing temperature over this temperature range. LiCl(aq) is somewhat unusual among the alkali-metal chlorides in that the osmotic (and activity) coefficient is much more dependent on molality at the higher molalities and there is no maximum between 273.15 and 373.15 K in the osmotic coefficient as a function of temperature. For both LiCl(aq) and CsCl(aq) there is an excellent correlation between the isopiestic results and the vapor pressures of Lindsay and Liu. Existing electrochemical results between 283.15 and 343.15 K are consistent with the calculated activity coefficients for CsCl(aq). (author)

  8. Isopiestic density law of actinide nitrates applied to criticality calculations

    International Nuclear Information System (INIS)

    Leclaire, Nicolas; Anno, Jacques; Courtois, Gerard; Poullot, Gilles; Rouyer, Veronique

    2003-01-01

    Up to now, criticality safety experts used density laws fitted on experimental data and applied them in and outside the measurement range. Depending on the case, such an approach could be wrong for nitrate solutions. Seven components are concerned: UO 2 (NO 3 ) 2 , U(NO 3 ) 4 , Pu(NO 3 ) 4 , Pu(NO 3 ) 3 , Th(NO 3 ) 4 , Am(NO 3 ) 3 and HNO 3 . To get rid of this problem, a new methodology based on the thermodynamic concept of binary electrolytes solutions mixtures at constant water activity, so called 'isopiestic' solutions, has been developed by IRSN to calculate the nitrate solutions density. This article shortly presents the theoretical aspects of the method, its qualification using benchmarks and its implementation in IRSN graphical user interface. (author)

  9. Isopiestic determination of the osmotic and activity coefficients of the {yKCl + (1 - y)K2HPO4}(aq) system at T = 298.15 K

    International Nuclear Information System (INIS)

    Popovic, Daniela Z.; Miladinovic, Jelena; Todorovic, Milica D.; Zrilic, Milorad M.; Rard, Joseph A.

    2011-01-01

    Highlights: → Isopiestic measurements were made for {yKCl + (1 - y)K 2 HPO 4 }(aq) at T = 298.15 K. → The resulting osmotic coefficients were represented by three thermodynamic models. → Activity coefficients from Pitzer model with Scatchard mixing terms are recommended. - Abstract: The osmotic coefficients of aqueous mixtures of KCl and K 2 HPO 4 have been measured at T = (298.15 ± 0.01) K by the isopiestic vapor pressure method over the range of ionic strengths from (2.3700 to 11.250) mol . kg -1 using CaCl 2 (aq) as the reference solution. Our new experimental results were modeled with an extended form of Pitzer's ion-interaction model equations, both with the usual mixing terms and with Scatchard's neutral-electrolyte mixing terms, and with the Clegg-Pitzer-Brimblecombe equations based on the mole-fraction-composition scale. There is a dearth of previously published isopiestic data for mixtures containing salts of HPO 4 2- (aq) and, consequently, no previous measurements are available for comparison with the present results. The present study yields Cl - HPO 4 2- mixing parameters for these three models that are needed for modeling the thermodynamic activities of solute components of natural waters and other complex aqueous electrolyte mixtures.

  10. Isopiestic determination of the osmotic coefficients and Pitzer model representation for Li{sub 2}B{sub 4}O{sub 7}(aq) at T=298.15 K

    Energy Technology Data Exchange (ETDEWEB)

    Zhang Aiyun [Qinghai Institute of Salt Lakes, Chinese Academy of Sciences, Xining 810008 (China); Hei Long Jiang Science and Technology College, Ha' erbin (China); Yao Yan [Qinghai Institute of Salt Lakes, Chinese Academy of Sciences, Xining 810008 (China)]. E-mail: yanyao@pub.xaonline.com; Li Lijuan [Qinghai Institute of Salt Lakes, Chinese Academy of Sciences, Xining 810008 (China); Song Pengsheng [Qinghai Institute of Salt Lakes, Chinese Academy of Sciences, Xining 810008 (China)

    2005-02-01

    Isopiestic molalities and water activities have been measured for aqueous Li{sub 2}B{sub 4}O{sub 7} solutions from (0.0275 to 2.9397) mol.kg{sup -1} at T=298.15 K by isopiestic method, using an improved apparatus. These measurements have extended into the very dilute and the supersaturated molality region. Two types of osmotic coefficients of {phi}{sub S} and {phi}{sub E} were determined. {phi}{sub S} is based on the stoichiometric molalities of the solute Li{sub 2}B{sub 4}O{sub 7}(aq), and {phi}{sub E} is based on equilibrium molalities based on consideration of the equilibrium speciation of H3BO3,B(OH)4-,B3O3(OH)4-,andB4O5(OH)42- in the Li{sub 2}B{sub 4}O{sub 7}(aq) solutions. The stoichiometric equilibrium constants K{sub mi} for the aqueous speciation reactions were estimated. Three types of representations of the osmotic coefficients for the (Li{sub 2}B{sub 4}O{sub 7}+H{sub 2}O) system with the ion-interaction models based on Pitzer's equations of osmotic coefficients with minor modifications were presented: the model (I) for representation of the data of {phi}{sub S} with four parameters based on considering the ion-interactions between two ionic species of Li+andB4O72-, the model (II) for representation of the data of {phi}{sub E} based on considering the equilibrium speciation with 18 parameters, and the model (III) simplified from model (II) with six ion-interaction parameters estimated. The reasonable agreements between the experimental osmotic coefficient data and those calculated using the models above were obtained with the standard deviations of 0.0215, 0.0055, and 0.0150 for the three models, respectively. The thermodynamic osmotic coefficient properties for the complex system containing polymetric boron anions and lithium may be explained by use of the Pitzer ion-interaction model with minor modifications in combination with speciation reaction equilibria.

  11. Isopiestic determination of the osmotic and activity coefficients of the {l_brace}yKCl + (1 - y)K{sub 2}HPO{sub 4}{r_brace}(aq) system at T = 298.15 K

    Energy Technology Data Exchange (ETDEWEB)

    Popovic, Daniela Z. [Faculty of Technology and Metallurgy, University of Belgrade, Karnegijeva 4, 11 001 Belgrade (Serbia); Miladinovic, Jelena, E-mail: duma@tmf.bg.ac.rs [Faculty of Technology and Metallurgy, University of Belgrade, Karnegijeva 4, 11 001 Belgrade (Serbia); Todorovic, Milica D.; Zrilic, Milorad M. [Faculty of Technology and Metallurgy, University of Belgrade, Karnegijeva 4, 11 001 Belgrade (Serbia); Rard, Joseph A., E-mail: solution_chemistry2@comcast.net [4363 Claremont Way, Livermore, CA 94550 (United States)

    2011-12-15

    Highlights: > Isopiestic measurements were made for {l_brace}yKCl + (1 - y)K{sub 2}HPO{sub 4}{r_brace}(aq) at T = 298.15 K. > The resulting osmotic coefficients were represented by three thermodynamic models. > Activity coefficients from Pitzer model with Scatchard mixing terms are recommended. - Abstract: The osmotic coefficients of aqueous mixtures of KCl and K{sub 2}HPO{sub 4} have been measured at T = (298.15 {+-} 0.01) K by the isopiestic vapor pressure method over the range of ionic strengths from (2.3700 to 11.250) mol . kg{sup -1} using CaCl{sub 2}(aq) as the reference solution. Our new experimental results were modeled with an extended form of Pitzer's ion-interaction model equations, both with the usual mixing terms and with Scatchard's neutral-electrolyte mixing terms, and with the Clegg-Pitzer-Brimblecombe equations based on the mole-fraction-composition scale. There is a dearth of previously published isopiestic data for mixtures containing salts of HPO{sub 4}{sup 2-}(aq) and, consequently, no previous measurements are available for comparison with the present results. The present study yields Cl{sup -}HPO{sub 4}{sup 2-} mixing parameters for these three models that are needed for modeling the thermodynamic activities of solute components of natural waters and other complex aqueous electrolyte mixtures.

  12. Minimum critical values of uranyl and plutonium nitrate solutions calculated by various routes of the french criticality codes system CRISTAL using the new isopiestic nitrate density law

    International Nuclear Information System (INIS)

    Anno, Jacques; Rouyer, Veronique; Leclaire, Nicolas

    2003-01-01

    This paper provides for various cases of 235 U enrichment or Pu isotopic vectors, and different reflectors, new minimum critical values of uranyl nitrate and plutonium nitrate solutions (H + =0) obtained by the standard IRSN calculation route and the new isopiestic density laws. Comparisons are also made with other more accurate routes showing that the standard one's results are most often conservative and usable for criticality safety assessments. (author)

  13. Residual gravimetric method to measure nebulizer output.

    Science.gov (United States)

    Vecellio None, Laurent; Grimbert, Daniel; Bordenave, Joelle; Benoit, Guy; Furet, Yves; Fauroux, Brigitte; Boissinot, Eric; De Monte, Michele; Lemarié, Etienne; Diot, Patrice

    2004-01-01

    The aim of this study was to assess a residual gravimetric method based on weighing dry filters to measure the aerosol output of nebulizers. This residual gravimetric method was compared to assay methods based on spectrophotometric measurement of terbutaline (Bricanyl, Astra Zeneca, France), high-performance liquid chromatography (HPLC) measurement of tobramycin (Tobi, Chiron, U.S.A.), and electrochemical measurements of NaF (as defined by the European standard). Two breath-enhanced jet nebulizers, one standard jet nebulizer, and one ultrasonic nebulizer were tested. Output produced by the residual gravimetric method was calculated by weighing the filters both before and after aerosol collection and by filter drying corrected by the proportion of drug contained in total solute mass. Output produced by the electrochemical, spectrophotometric, and HPLC methods was determined after assaying the drug extraction filter. The results demonstrated a strong correlation between the residual gravimetric method (x axis) and assay methods (y axis) in terms of drug mass output (y = 1.00 x -0.02, r(2) = 0.99, n = 27). We conclude that a residual gravimetric method based on dry filters, when validated for a particular agent, is an accurate way of measuring aerosol output.

  14. Gravimetric determination of uranium in SALE samples

    International Nuclear Information System (INIS)

    Anon.

    1981-01-01

    As a participant in the Safeguards Analytical Laboratory Evaluation (SALE) program, the Analytical Chemistry Laboratory at General Atomic routinely assays uranium dioxide and uranyl nitrate SALE samples for uranium content. Gravimetric methods are relatively easy and inexpensive to apply when the samples for uranium content. Gravimetric methods are relatively easy and inexpensive to apply when the samples are free from substantial amounts of metallic impurities. Clearly the gravimetric procedure alone is not specific for uranium and must be enhanced by the use of impurity corrections. Emission spectrography is used routinely as the technique of choice for making such corrections. In cases where it is essential to assay specifically for uranium, the modified Davies-Gray titration using a weighed titrant method is applied. In this paper some essential features of these gravimetric and titrimetric procedures are discussed

  15. Isopiestic Investigation of the Osmotic and Activity Coefficients of {yMgCl2 + (1 - y)MgSO4}(aq) and the Osmotic Coefficients of Na2SO4.MgSO4(aq) at 298.15 K

    Energy Technology Data Exchange (ETDEWEB)

    Miladinovic, J; Ninkovic, R; Todorovic, M; Rard, J A

    2007-06-06

    Isopiestic vapor pressure measurements were made for {l_brace}yMgCl{sub 2} + (1-y)MgSO{sub 4}{r_brace}(aq) solutions with MgCl{sub 2} ionic strength fractions of y = 0, 0.1997, 0.3989, 0.5992, 0.8008, and (1) at the temperature 298.15 K, using KCl(aq) as the reference standard. These measurements for the mixtures cover the ionic strength range I = 0.9794 to 9.4318 mol {center_dot} kg{sup -1}. In addition, isopiestic measurements were made with NaCl(aq) as reference standard for mixtures of {l_brace}xNa{sub 2}SO{sub 4} + (1-x)MgSO{sub 4}{r_brace}(aq) with the molality fraction x = 0.50000 that correspond to solutions of the evaporite mineral bloedite (astrakanite), Na{sub 2}Mg(SO{sub 4}){sub 2} {center_dot} 4H{sub 2}O(cr). The total molalities, m{sub T} = m(Na{sub 2}SO{sub 4}) + m(MgSO{sub 4}), range from m{sub T} = 1.4479 to 4.4312 mol {center_dot} kg{sup -1} (I = 5.0677 to 15.509 mol {center_dot} kg{sup -1}), where the uppermost concentration is the highest oversaturation molality that could be achieved by isothermal evaporation of the solvent at 298.15 K. The parameters of an extended ion-interaction (Pitzer) model for MgCl2(aq) at 298.15 K, which were required for an analysis of the {l_brace}yMgCl{sub 2} + (1-y)MgSO{sub 4}{r_brace}(aq) mixture results, were evaluated up to I = 12.025 mol {center_dot} kg{sup -1} from published isopiestic data together with the six new osmotic coefficients obtained in this study. Osmotic coefficients of {l_brace}yMgCl{sub 2} + (1-y)MgSO{sub 4}{r_brace}(aq) solutions from the present study, along with critically-assessed values from previous studies, were used to evaluate the mixing parameters of the extended ion-interaction model.

  16. Zirconium determination in refractories (gravimetric method)

    International Nuclear Information System (INIS)

    Capiotto, N.; Narahashi, Y.; Perish, P.G.; Souza, J.R. de

    1991-01-01

    A gravimetric method for zirconium determination in refractories is described. X-ray fluorescence analysis is also employed in this experiment and considerations about interfering elements are presented. (M.V.M.)

  17. Zirconium determination in refractories (gravimetric method)

    International Nuclear Information System (INIS)

    Capiotto, N.; Narahashi, Y.; Perish, C.G.; Souza, J.R.

    1991-01-01

    The zirconium determination in refractories is described, consisting in two separation methods for eliminating the interferences. The formatted product is calcined at 1100 0 C and determined gravimetrically as Zr P z 07. (author)

  18. Gravimetric and titrimetric methods of analysis

    International Nuclear Information System (INIS)

    Rives, R.D.; Bruks, R.R.

    1983-01-01

    Gravimetric and titrimetric methods of analysis are considered. Methods of complexometric titration are mentioned, as well as methods of increasing sensitivity in titrimetry. Gravimetry and titrimetry are applied during analysis for traces of geological materials

  19. Gravimetric gas determinations for volume calibration

    International Nuclear Information System (INIS)

    Gibbs, P.W.

    1991-01-01

    Gravimetric measurements of gases is one of the methods available for calibrating gas volumes. By inputting a known quantity of gas and measuring the resulting pressure and temperature, the system volume can be calculated using gas law principles. Historically, this method has been less accurate due to the difficulty in the mass determination. This difficulty comes from several sources. Two examples are the large tare weight of the gas container relative to the weight of gas and the external volume of the gas container relative to the standards. The application of a gravimetric gas determination to tank volume calibrations at the savannah River Site is discussed. Mass determinations on a 25,00 gram gas container were such that a 1500 gram quantity of gas was routinely determined to within ±0.2 gram at the 99% confidence level. In this paper the weighting design and the methods used to address the difficulties of the mass determination are detailed

  20. Comparison of Potentiometric and Gravimetric Methods for Determination of O/U Ratio

    International Nuclear Information System (INIS)

    Farida; Windaryati, L; Putro Kasino, P

    1998-01-01

    Comparison of determination O/U ratio by using potentiometric and gravimetric methods has been done. Those methods are simple, economical and having high precision and accuracy. Determination O/U ratio for UO 2 powder using potentiometric is carried out by adopting the davies-gray method. This technique is based on the redox reaction of uranium species such as U(IV) and U(VI). In gravimetric method,the UO 2 power as a sample is calcined at temperature of 900 C, and the weight of the sample is measured after calcination process. The t-student test show that there are no different result significantly between those methods. However, for low concentration in the sample the potentiometric method has a highed precision and accuracy compare to the gravimetric method. O/U ratio obtained is 2.00768 ± 0,00170 for potentiometric method 2.01089 ± 0,02395 for gravimetric method

  1. Combination volumetric and gravimetric sorption instrument for high accuracy measurements of methane adsorption

    Science.gov (United States)

    Burress, Jacob; Bethea, Donald; Troub, Brandon

    2017-05-01

    The accurate measurement of adsorbed gas up to high pressures (˜100 bars) is critical for the development of new materials for adsorbed gas storage. The typical Sievert-type volumetric method introduces accumulating errors that can become large at maximum pressures. Alternatively, gravimetric methods employing microbalances require careful buoyancy corrections. In this paper, we present a combination gravimetric and volumetric system for methane sorption measurements on samples between ˜0.5 and 1 g. The gravimetric method described requires no buoyancy corrections. The tandem use of the gravimetric method allows for a check on the highest uncertainty volumetric measurements. The sources and proper calculation of uncertainties are discussed. Results from methane measurements on activated carbon MSC-30 and metal-organic framework HKUST-1 are compared across methods and within the literature.

  2. Gravimetric method for the determination of diclofenac in pharmaceutical preparations.

    Science.gov (United States)

    Tubino, Matthieu; De Souza, Rafael L

    2005-01-01

    A gravimetric method for the determination of diclofenac in pharmaceutical preparations was developed. Diclofenac is precipitated from aqueous solution with copper(II) acetate in pH 5.3 (acetic acid/acetate buffer). Sample aliquots had approximately the same quantity of the drug content in tablets (50 mg) or in ampules (75 mg). The observed standard deviation was about +/- 2 mg; therefore, the relative standard deviation (RSD) was approximately 4% for tablet and 3% for ampule preparations. The results were compared with those obtained with the liquid chromatography method recommended in the United States Pharmacopoeia using the statistical Student's t-test. Complete agreement was observed. It is possible to obtain more precise results using higher aliquots, for example 200 mg, in which case the RSD falls to 1%. This gravimetric method, contrary to what is expected for this kind of procedure, is relatively fast and simple to perform. The main advantage is the absolute character of the gravimetric analysis.

  3. A detailed gravimetric geoid from North America to Eurasia

    Science.gov (United States)

    Vincent, S. F.; Strange, W. E.; Marsh, J. G.

    1972-01-01

    A detailed gravimetric geoid of the United States, North Atlantic, and Eurasia, which was computed from a combination of satellite derived and surface gravity data, is presented. The precision of this detailed geoid is + or - 2 to + or - 3 m in the continents but may be in the range of 5 to 7 m in those areas where data is sparse. Comparisons of the detailed gravimetric geoid with results of Rapp, Fischer, and Rice for the United States, Bomford in Europe, and Heiskanen and Fischer in India are presented. Comparisons are also presented with geoid heights from satellite solutions for geocentric station coordinates in North America, the Caribbean, and Europe.

  4. Combined Colorimetric and Gravimetric CMUT Sensor for Detection of Phenylacetone

    DEFF Research Database (Denmark)

    Mølgaard, Mathias Johannes Grøndahl; Laustsen, Milan; Thygesen, Ida Lysgaard

    2017-01-01

    The detection of phenylacetone is of interest as it is a common precursor for the synthesis of (meth)amphetamine. Resonant gravimetric sensors can be used to detect the mass and hereby the concentration of a gas while colorimetric arrays typically have an exceptional selectivity to the target...... analyte if the right colorimetric dyes are chosen. We present a sensor system consisting of a Capacitive Micromachined Ultrasonic Transducer (CMUT) and a colorimetric array for detection of phenylacetone. The CMUT is used as a resonant gravimetric gas sensor where the resonance frequency shift due to mass...

  5. Gravimetric Analysis of Uranium in Yellow Cake

    International Nuclear Information System (INIS)

    Srinuttrakul, Wannee; Jantha, Suwat

    2007-08-01

    Full text: The gravimetric analysis of uranium in yellow cake is composed of several stages. The analysis takes a long time, which is the disadvantage of this method. However, this gravimetric method provides accurate result for determining the major content of sample. Uranium is the main composition of yellow cake, while Thorium, rare earths and other elements are minor and trace elements. In this work, anion exchange resin was used to separate uranium from other elements to yield highly pure uranium suitable for precipitation. This pure uranium was burnt to U3O8, a form that is stable enough to be weighed. From the optimal condition, the recovery of U3O8 after separating uranium from rare earths and iron is 99.85 ± 0.21%. The application of anion exchange separation was used to analyze uranium in yellow cake obtained from monazite digestion process. It was found that U3O8 in yellow cake is 78.85 ± 2.03%

  6. Measuring intestinal fluid transport in vitro: Gravimetric method versus non-absorbable marker.

    Science.gov (United States)

    Whittamore, Jonathan M; Genz, Janet; Grosell, Martin; Wilson, Rod W

    2016-04-01

    The gut sac is a long-standing, widely used in vitro preparation for studying solute and water transport, and calculation of these fluxes requires an accurate assessment of volume. This is commonly determined gravimetrically by measuring the change in mass over time. While convenient this likely under-estimates actual net water flux (Jv) due to tissue edema. We evaluated whether the popular in vivo volume marker [(14)C]-PEG 4000, offers a more representative measure of Jvin vitro. We directly compared these two methods in five teleost species (toadfish, flounder, rainbow trout, killifish and tilapia). Net fluid absorption by the toadfish intestine based on PEG was significantly higher, by almost 4-fold, compared to gravimetric measurements, compatible with the latter under-estimating Jv. Despite this, PEG proved inconsistent for all of the other species frequently resulting in calculation of net secretion, in contrast to absorption seen gravimetrically. Such poor parallelism could not be explained by the absorption of [(14)C]-PEG (typically gravimetric method therefore remains the most reliable measure of Jv and we urge caution in the use of PEG as a volume marker. Copyright © 2016 Elsevier Inc. All rights reserved.

  7. Zero drift and solid Earth tide extracted from relative gravimetric data with principal component analysis

    OpenAIRE

    Hongjuan Yu; Jinyun Guo; Jiulong Li; Dapeng Mu; Qiaoli Kong

    2015-01-01

    Zero drift and solid Earth tide corrections to static relative gravimetric data cannot be ignored. In this paper, a new principal component analysis (PCA) algorithm is presented to extract the zero drift and the solid Earth tide, as signals, from static relative gravimetric data assuming that the components contained in the relative gravimetric data are uncorrelated. Static relative gravity observations from Aug. 15 to Aug. 23, 2014 are used as statistical variables to separate the signal and...

  8. 40 CFR 1065.290 - PM gravimetric balance.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 32 2010-07-01 2010-07-01 false PM gravimetric balance. 1065.290... balance. (a) Application. Use a balance to weigh net PM on a sample medium for laboratory testing. (b) Component requirements. We recommend that you use a balance that meets the specifications in Table 1 of...

  9. A gravimetric simplified method for nucleated marrow cell counting using an injection needle.

    Science.gov (United States)

    Saitoh, Toshiki; Fang, Liu; Matsumoto, Kiyoshi

    2005-08-01

    A simplified gravimetric marrow cell counting method for rats is proposed for a regular screening method. After fresh bone marrow was aspirated by an injection needle, the marrow cells were suspended in carbonate buffered saline. The nucleated marrow cell count (NMC) was measured by an automated multi-blood cell analyzer. When this gravimetric method was applied to rats, the NMC of the left and right femurs had essentially identical values due to careful handling. The NMC at 4 to 10 weeks of age in male and female Crj:CD(SD)IGS rats was 2.72 to 1.96 and 2.75 to 1.98 (x10(6) counts/mg), respectively. More useful information for evaluation could be obtained by using this gravimetric method in addition to myelogram examination. However, some difficulties with this method include low NMC due to blood contamination and variation of NMC due to handling. Therefore, the utility of this gravimetric method for screening will be clarified by the accumulation of the data on myelotoxicity studies with this method.

  10. Preliminary study of gravimetric anomalies in the Magallanes-Fagnano fault system, South America

    Directory of Open Access Journals (Sweden)

    Juan Manuel Alcacer

    2018-01-01

    Full Text Available The main objective of this research is to recognize several geological structures associated with the shear zones of the MFFS (Magallanes – Fagnano fault system by the analysis and interpretation of gravimetric anomalies. Besides, to compare the gravimetrical response of the cortical blocks that integrate the region under study, which is related to the different morphotectonic domains recognized in the region. This research was developed employing data obtained from World Gravity 1.0, which includes earth and satellite gravity data derived from the EGM2008 model. The study and interpretation of the MFFS from the analysis and processing of the gravimetric data, allowed appreciation of a noticeable correlation with the most superficial cortical structure.

  11. Comparison of macro-gravimetric and micro-colorimetric lipid determination methods.

    Science.gov (United States)

    Inouye, Laura S; Lotufo, Guiherme R

    2006-10-15

    In order to validate a method for lipid analysis of small tissue samples, the standard macro-gravimetric method of Bligh-Dyer (1959) [E.G. Bligh, W.J. Dyer, Can. J. Biochem. Physiol. 37 (1959) 911] and a modification of the micro-colorimetric assay developed by Van Handel (1985) [E. Van Handel, J. Am. Mosq. Control Assoc. 1 (1985) 302] were compared. No significant differences were observed for wet tissues of two species of fish. However, limited analysis of wet tissue of the amphipod, Leptocheirusplumulosus, indicated that the Bligh-Dyer gravimetric method generated higher lipid values, most likely due to the inclusion of non-lipid materials. Additionally, significant differences between the methods were observed with dry tissues, with the micro-colorimetric method consistently reporting calculated lipid values greater than as reported by the gravimetric method. This was most likely due to poor extraction of dry tissue in the standard Bligh-Dyer method, as no significant differences were found when analyzing a single composite extract. The data presented supports the conclusion that the micro-colorimetric method described in this paper is accurate, rapid, and minimizes time and solvent use.

  12. Interpretation of Gravimetric and Aeromagnetic Data of the Tecoripa Chart in Southeast Sonora, Mexico.

    Science.gov (United States)

    Martínez-Retama, S.; Montaño-Del Cid, M. A.

    2015-12-01

    The Tecoripa chart H12-D64 is located southeast of the state of Sonora, México, south of Arizona. The geology is represented by sedimentary rocks of the Ordovician and Triassic, volcanic rocks of the Upper Cretaceous and Tertiary, intrusive rocks from the Upper Cretaceous- Tertiary and sedimentary rocks of the Cenozoic. In this paper a gravimetric study was conducted to determine the configuration and depth of the basement and to develop a structural model of the subsurface. For this purpose a consistent gravimetric survey in 3 profiles was conducted. To complement this study, gravimetric data obtained by INEGI (96 gravimetric stations spaced every 4000 m) that correspond to a regional survey was also used. The two sets of data were corrected and processed with the WinGLink software. The profiles were then modeled using the Talwani method. 4 Profiles corresponding to the gravimetric survey and 5 data profiles from INEGI were modeled. Aeromagnetic data from the total field of Tecoripa chart were also processed. The digital information was integrated and processed by generating a data grid. Processes applied to data consisted of reduction to the pole, regional-residual separation and upward continuations. In general, the obtained structural models show intrusive bodies associated with well-defined high gravimetric and magnetic and low gravimetric and magnetic are associated with basins and sedimentary rocks. The obtained geological models show the basement represented by volcanic rocks of the Tarahumara Formation from the Upper Cretaceous which are in contact with sedimentary rocks from the Barranca Group from Upper Cretaceous and limestones from the Middle Ordovician. Both volcanic and sedimentary rocks are intruded by granodiorite- granite with ages of the Tertiary-Oligocene. Based on the superficial geology as well as in the configuration of the basement and the obtained structural model the existence of faults with NW-SE orientation that originate Horst and

  13. Comparison of fine particle measurements from a direct-reading instrument and a gravimetric sampling method.

    Science.gov (United States)

    Kim, Jee Young; Magari, Shannon R; Herrick, Robert F; Smith, Thomas J; Christiani, David C

    2004-11-01

    Particulate air pollution, specifically the fine particle fraction (PM2.5), has been associated with increased cardiopulmonary morbidity and mortality in general population studies. Occupational exposure to fine particulate matter can exceed ambient levels by a large factor. Due to increased interest in the health effects of particulate matter, many particle sampling methods have been developed In this study, two such measurement methods were used simultaneously and compared. PM2.5 was sampled using a filter-based gravimetric sampling method and a direct-reading instrument, the TSI Inc. model 8520 DUSTTRAK aerosol monitor. Both sampling methods were used to determine the PM2.5 exposure in a group of boilermakers exposed to welding fumes and residual fuel oil ash. The geometric mean PM2.5 concentration was 0.30 mg/m3 (GSD 3.25) and 0.31 mg/m3 (GSD 2.90)from the DUSTTRAK and gravimetric method, respectively. The Spearman rank correlation coefficient for the gravimetric and DUSTTRAK PM2.5 concentrations was 0.68. Linear regression models indicated that log, DUSTTRAK PM2.5 concentrations significantly predicted loge gravimetric PM2.5 concentrations (p gravimetric PM2.5 concentrations was found to be modified by surrogate measures for seasonal variation and type of aerosol. PM2.5 measurements from the DUSTTRAK are well correlated and highly predictive of measurements from the gravimetric sampling method for the aerosols in these work environments. However, results from this study suggest that aerosol particle characteristics may affect the relationship between the gravimetric and DUSTTRAK PM2.5 measurements. Recalibration of the DUSTTRAK for the specific aerosol, as recommended by the manufacturer, may be necessary to produce valid measures of airborne particulate matter.

  14. Reduction Of Gravimetric Data Using An Integrated Computer ...

    African Journals Online (AJOL)

    The rigour of gravimetric data collection, and the non-availability of comprehensive data reduction software that takes care of local peculiarities, have always constituted hindrance to the application of the gravity method of geophysical studies. However, in recent time, the importance of the gravity method in mineral ...

  15. Technical note: Comparison of metal-on-metal hip simulator wear measured by gravimetric, CMM and optical profiling methods

    Science.gov (United States)

    Alberts, L. Russell; Martinez-Nogues, Vanesa; Baker Cook, Richard; Maul, Christian; Bills, Paul; Racasan, R.; Stolz, Martin; Wood, Robert J. K.

    2018-03-01

    Simulation of wear in artificial joint implants is critical for evaluating implant designs and materials. Traditional protocols employ the gravimetric method to determine the loss of material by measuring the weight of the implant components before and after various test intervals and after the completed test. However, the gravimetric method cannot identify the location, area coverage or maximum depth of the wear and it has difficulties with proportionally small weight changes in relatively heavy implants. In this study, we compare the gravimetric method with two geometric surface methods; an optical light method (RedLux) and a coordinate measuring method (CMM). We tested ten Adept hips in a simulator for 2 million cycles (MC). Gravimetric and optical methods were performed at 0.33, 0.66, 1.00, 1.33 and 2 MC. CMM measurements were done before and after the test. A high correlation was found between the gravimetric and optical methods for both heads (R 2  =  0.997) and for cups (R 2  =  0.96). Both geometric methods (optical and CMM) measured more volume loss than the gravimetric method (for the heads, p  =  0.004 (optical) and p  =  0.08 (CMM); for the cups p  =  0.01 (optical) and p  =  0.003 (CMM)). Two cups recorded negative wear at 2 MC by the gravimetric method but none did by either the optical method or by CMM. The geometric methods were prone to confounding factors such as surface deformation and the gravimetric method could be confounded by protein absorption and backside wear. Both of the geometric methods were able to show the location, area covered and depth of the wear on the bearing surfaces, and track their changes during the test run; providing significant advantages to solely using the gravimetric method.

  16. Crumpled Nitrogen-Doped Graphene for Supercapacitors with High Gravimetric and Volumetric Performances.

    Science.gov (United States)

    Wang, Jie; Ding, Bing; Xu, Yunling; Shen, Laifa; Dou, Hui; Zhang, Xiaogang

    2015-10-14

    Graphene is considered a promising electrochemical capacitors electrode material due to its high surface area and high electrical conductivity. However, restacking interactions between graphene nanosheets significantly decrease the ion-accessible surface area and impede electronic and ionic transfer. This would, in turn, severely hinder the realization of high energy density. Herein, we report a strategy for preparation of few-layer graphene material with abundant crumples and high-level nitrogen doping. The two-dimensional graphene nanosheets (CNG) feature high ion-available surface area, excellent electronic and ion transfer properties, and high packing density, permitting the CNG electrode to exhibit excellent electrochemical performance. In ionic liquid electrolyte, the CNG electrode exhibits gravimetric and volumetric capacitances of 128 F g(-1) and 98 F cm(-3), respectively, achieving gravimetric and volumetric energy densities of 56 Wh kg(-1) and 43 Wh L(-1). The preparation strategy described here provides a new approach for developing a graphene-based supercapacitor with high gravimetric and volumetric energy densities.

  17. Gravimetric and profilometric measurements of the ablation rates of photosensitive polymers at different wavelengths

    International Nuclear Information System (INIS)

    Dumont, Th.; Bischofberger, R.; Lippert, T.; Wokaun, A.

    2005-01-01

    The ablation rates of two polyimides (PMDA and DurimidTM) and one triazene polymer were studied by gravimetric (quartz microbalance) and profilometric (profilometer) methods at irradiation wavelengths of 193, 248 and 308 nm. The ablation rates determined by the two methods are discussed in the context of the absorption behavior of the materials. Furthermore, the consistence of the two experimental methods is discussed for the ablation rates of DurimidTM and the triazene polymer. The gravimetric measurements revealed a good correlation between the ablation rate and the absorption properties of the examined materials. The comparison of the gravimetric and the profilometric measurements suggest a significant mass removal, e.g. by formation of gaseous products, prior to the detection of changes in the surface morphology

  18. A study on improvement of measurement capability for gravimetric flowmeter calibrator

    International Nuclear Information System (INIS)

    Lee, Dong Keun; Park, Jong Ho

    2009-01-01

    The calibration of flowmeter is a very important procedure to set up traceability from the national or international standards. The uncertainty of flow measurement defines reliability for measurement results. The uncertainty of gravimetric method combines uncertainties of each independent variable, including mass, time, water density, air density and the density of dead weight. In this study, it has been found that the uncertainties of mass and time measurement in the gravimetric method have dominant influence on the total measurement uncertainty. After improvements of a constant head tank and a diverter, the best measurement capability for K-water's calibration facility has been reached less than 0.1%.

  19. Dynamic study of adsorbers by a new gravimetric version of the Large Temperature Jump method

    International Nuclear Information System (INIS)

    Sapienza, Alessio; Santamaria, Salvatore; Frazzica, Andrea; Freni, Angelo; Aristov, Yuri I.

    2014-01-01

    Highlights: • We have carried out a dynamic study of adsorbers. • Activity performed by new gravimetric version of the Large Temperature Jump method. • The kinetics measurements have been carried out under real operating conditions. • Results can support the design of adsorbers for adsorption cooling systems. - Abstract: This paper presents a new experimental setup devoted to measure the ad-/desorption kinetics of an Ad-HEX (adsorbent + heat exchanger) under typical boundary conditions of an Adsorption Heat Transformer (AHT) as well as the results of the first test campaign carried out. The experimental apparatus can be considered as a gravimetric version of the known Large Temperature Jump method. In fact, the dynamic evolution of the uptake during the isobaric ad-/desorption stages is directly measured by a weighing system suitable to work in the range of 5–600 g of sample mass (adsorbent + HEX) with the accuracy ±0.1 g and the time response shorter than 0.1 s The experimental campaign was conducted on an Ad-HEX composed of granules of a commercial SAPO-34 adsorbent placed on a flat type aluminum HEX, under operating conditions reproducing two different thermodynamic cycles (T h = 90 °C, T e = 10 °C, T c = 30 and 35 °C), typical for adsorption air conditioning. The influence of the grain size (ranging from 0.350 to 2.5 mm) on the adsorption dynamics both in monolayer and multilayer configurations at variable and constant “heat transfer surface/adsorbent mass” ratios (S/m) was studied. The results showed that, for the Ad-HEX configurations tested, the adsorption dynamics can be properly described by a modified Linear Driving Force approach by the use of a single temperature-invariant characteristic time τ. The invariance of the specific cooling power was revealed when the S/m ratio was kept constant (S/m = 1.23 m 2 /kg). This ratio is found to be a useful parameter for both assessment of the dynamic perfection and optimization of various Ad

  20. Quartz analysis in gravimetric sampling

    International Nuclear Information System (INIS)

    Rex, D.A.

    1990-01-01

    An overview of the methods employed in the assessment of quartz exposure is provided. The principles and some of the problems associated with each method is discussed. The methods reviewed include wet chemical methods, X-ray diffraction and infrared absorption of which the latter two methods are deemed appropriate for analysing quartz on personal gravimetric collected samples. The implications of combining area samples collected over a six month period, and performing only a single quartz analysis rather than separate analyses, are considered. Finally, various options open to mines with regard to their involvement with quartz analysis are also briefly discussed. 35 refs., 6 figs., 1 tab

  1. A new apparatus for the determination of adsorption isotherms and adsorption enthalpies on microporous and meso-porous media

    International Nuclear Information System (INIS)

    Mouahid, A.

    2010-01-01

    A specific thermostated experimental device comprising a differential heat flow calorimeter coupled with a home built manometric system has been built for the simultaneous determination of adsorption isotherms and adsorption enthalpies. The differential heat flow calorimeter is a Tian Calvet Setaram C80 model which measures the heat flux of a gas and can be operated isothermally, the manometric system is a stainless steel homemade apparatus. This coupled apparatus allows measurements for pressure up to 2.5 MPa and temperature up to 423.15 K. On the one hand, the apparatus and the experimental procedures are described. On the second hand the reliability and reproducibility were established by measuring adsorption isotherms on a benchmark (Filtrasorb F400) at 318.15 K. The gravimetric method has been used at higher pressure at various temperatures. These devices allowed us to study the adsorption of supercritical fluid (nitrogen N 2 , methane CH 4 , carbon dioxide CO 2 ) in activated carbons and microporous or meso-porous silica. The adsorption of methane on a rock of type (TGR) was also studied. These experimental results are used for the study of the interactions fluid / solid that must be taken into account in molecular simulations or DFT theory. (author)

  2. Spectrophotometric, potentiometric, and gravimetric determination of lanthanides with peri-dihydroxynaphthindenone

    International Nuclear Information System (INIS)

    Hassan, S.S.M.; Mahmoud, W.H.

    1982-01-01

    Sensitive and reasonably selective methods are described for the spectrophotometric, potentiometric, and gravimetric determination of lanthanides using peri-dihydroxynaphthindenone as a novel chromogenic and precipitating reagent. The reagent forms a stable 1:2 (metal:reagent) type of complex with light lanthanides at pH 2-7 in 1:1 ethanol-water mixture. Low metal concentrations ( 4 L mol -1 cm -1 ) which obey Beer's law. Quantitative precipitation of the complexes from metal solutions of concentrations > 100 μg/mL permits both gravimetric quantitation by igniting the precipitates to the metal oxides and potentiometric titration of the excess reagent. Results with an average recovery of 98% (standard deviation 0.7%) are obtainable for 0.1 μg to 200 mg of all light lanthanides. Many foreign ions naturally occurring or frequently associated with lanthanides do not interfere or can be tolerated

  3. Accuracy criteria recommended for the certification of gravimetric coal-mine-dust samplers

    International Nuclear Information System (INIS)

    Bowman, J.D.; Bartley, D.L.; Breuer, G.M.; Doemeny, L.J.; Murdock, D.J.

    1984-07-01

    Procedures for testing bias and precision of gravimetric coal-mine-dust sampling units are reviewed. Performance criteria for NIOSH certification of personal coal-mine dust samplers are considered. The NIOSH criterion is an accuracy of 25% at the 95% confidence interval. Size distributions of coal-mine-dust are discussed. Methods for determining size distributions are described. Sampling and sizing methods are considered. Cyclone parameter estimation is discussed. Bias computations for general sampling units are noted. Recommended procedures for evaluating bias and precision of gravimetric coal mine dust personal samplers are given. The authors conclude that when cyclones are operated at lower rates, the NIOSH accuracy criteria can be met

  4. Gravimetric dust sampling for control purposes and occupational dust sampling.

    CSIR Research Space (South Africa)

    Unsted, AD

    1997-02-01

    Full Text Available Prior to the introduction of gravimetric dust sampling, konimeters had been used for dust sampling, which was largely for control purposes. Whether or not absolute results were achievable was not an issue since relative results were used to evaluate...

  5. Gravimetric determination of beryllium in the presence of transition metals

    International Nuclear Information System (INIS)

    Morozova, S.S.; Nikitina, L.V.; Dyatlova, N.M.; Serebryakova, G.V.; Vol'nyagina, A.N.

    1976-01-01

    A new organic reagent, nitrolotrimethylphosphonic acid (H 6 L), is proposed for gravimetric determination of beryllium. This complexone forms with Be hardly soluble complexes in a wide pH range. The separated complex has a composition Be 5 (HL) 2 x10H 2 O. To elucidate the possibility of determining Be in the presence of transition metals, often accompanying beryllium in alloys, interaction of cations of these metals with H 6 L at different pH has been studied potentiometrically. It has been established that at pH=1.1 in the presence of masking reagent (diethylentriaminopentacetic acid) Be can be determined when zinc, copper, chromium, cobalt, nickel, iron, manganese and cadmium are present. Gravimetric method of determining Be with the help of H 6 L has been developed. The weight form is obtained by drying the precipitate which reduces considerably the time of analysis and the error of determination

  6. Gravimetric determination of the iodine number of carbon black

    International Nuclear Information System (INIS)

    Murphy, L.J. Jr.

    1991-01-01

    This paper discusses a gravimetric method for the determination of the iodine adsorption number of carbon black. It comprises determining the concentration of an accurately weighed iodine blank solution by adding a standardized titrant to the iodine solution until a titration endpoint is reached and determining the concentration of the iodine solution by accurately weighing the amount of the standardized titrant necessary to reach the endpoint, accurately weighing an amount of carbon black and adding an appropriate amount of an accurately weighed portion of the iodine solution, equilibrating the carbon black-iodine solution mixture, adding the standardized titrant to an accurately weighed portion of the supernatant from the carbon black-iodine mixture until a titration endpoint is reached and determining the concentration of the supernatant by accurately weighing the amount of the standardized titrant necessary to reach the endpoint, wherein the titration endpoint of the supernatant is obtained using an indicating and a reference electrode, and calculating the iodine adsorption number of the carbon black based on the gravimetrically determined concentration of the titrant, the iodine solution, and the supernatant

  7. Determination of uranium in uranyl nitrate solutions of nuclear grade quality - Gravimetric method

    International Nuclear Information System (INIS)

    1990-01-01

    This international Standard specifies a precise and accurate gravimetric method for determining the uranium content in uranyl nitrate product solutions of nuclear grade quality at concentrations above 100 g/l of uranium. Non-volatile impurities influence the accuracy of the method. Uranyl nitrate is converted into uranium octoxide (U 3 O 8 ) by ignition in air to constant mass at 900 deg. C ± 10 deg. C. Calculation of the uranium content in the sample using a gravimetric conversion factor which depends on the isotopic composition of the uranium. The isotopic composition is determined by mass spectrometry

  8. Gravimetric study on the western edge of the Rio de La Plata craton

    International Nuclear Information System (INIS)

    Rame, G; Miro, R

    2010-01-01

    This work is about the gravimetric study on the western edge of the Rio de la Plata craton which belongs to the Gondwana fragment in the south of Brazil, Uruguay and central eastern of Argentina. The work consisted of a survey of 332 gravimetric and topographic stations extended from the western edge of the Sierra Chica de Cordoba up to 200 km east on the pampas. The gravity values observed (gobs) were obtained using a LaCoste §Rom berg gravimeter G-961 and 200T Sodin both with 0.01 mGal, referred to IGSN71 (International Gravity Standardization Net 1971) network

  9. Decomposition of Copper (II) Sulfate Pentahydrate: A Sequential Gravimetric Analysis.

    Science.gov (United States)

    Harris, Arlo D.; Kalbus, Lee H.

    1979-01-01

    Describes an improved experiment of the thermal dehydration of copper (II) sulfate pentahydrate. The improvements described here are control of the temperature environment and a quantitative study of the decomposition reaction to a thermally stable oxide. Data will suffice to show sequential gravimetric analysis. (Author/SA)

  10. Development of a high-pressure microbalance for hydrogen storage materials

    DEFF Research Database (Denmark)

    Vestbø, Andreas Peter; Jensen, Jens Oluf; Bjerrum, Niels

    2007-01-01

    Pressure-composition isotherms (PCI's) help to determine thermodynamic properties related to hydrogen uptake of materials. PCI's are normally obtained volumetrically with a Sieverts type apparatus or gravimetrically with a microbalance. A potential problem with the gravimetric technique is that t......Pressure-composition isotherms (PCI's) help to determine thermodynamic properties related to hydrogen uptake of materials. PCI's are normally obtained volumetrically with a Sieverts type apparatus or gravimetrically with a microbalance. A potential problem with the gravimetric technique...... of an electromagnetic microbalance, pressure resistant casing for up to 100 bar hydrogen, a flow system for hydrogen and inert gas, heating elements for temperature control, and software for controlling the system. Thermal convection effects are observed and dampened by heating on both the sample and a counterweight...

  11. Precise and efficient evaluation of gravimetric quantities at arbitrarily scattered points in space

    Science.gov (United States)

    Ivanov, Kamen G.; Pavlis, Nikolaos K.; Petrushev, Pencho

    2017-12-01

    Gravimetric quantities are commonly represented in terms of high degree surface or solid spherical harmonics. After EGM2008, such expansions routinely extend to spherical harmonic degree 2190, which makes the computation of gravimetric quantities at a large number of arbitrarily scattered points in space using harmonic synthesis, a very computationally demanding process. We present here the development of an algorithm and its associated software for the efficient and precise evaluation of gravimetric quantities, represented in high degree solid spherical harmonics, at arbitrarily scattered points in the space exterior to the surface of the Earth. The new algorithm is based on representation of the quantities of interest in solid ellipsoidal harmonics and application of the tensor product trigonometric needlets. A FORTRAN implementation of this algorithm has been developed and extensively tested. The capabilities of the code are demonstrated using as examples the disturbing potential T, height anomaly ζ , gravity anomaly Δ g , gravity disturbance δ g , north-south deflection of the vertical ξ , east-west deflection of the vertical η , and the second radial derivative T_{rr} of the disturbing potential. After a pre-computational step that takes between 1 and 2 h per quantity, the current version of the software is capable of computing on a standard PC each of these quantities in the range from the surface of the Earth up to 544 km above that surface at speeds between 20,000 and 40,000 point evaluations per second, depending on the gravimetric quantity being evaluated, while the relative error does not exceed 10^{-6} and the memory (RAM) use is 9.3 GB.

  12. Some technical details concerning a new method of gravimetric-seismic inversion

    DEFF Research Database (Denmark)

    Strykowski, Gabriel

    1999-01-01

    In this paper a number of technical details related to a new method of gravimetric-seismic inversion, which is still under development, are explained. Although the present contribution aims on providing general statements on how to formulate and solve complex gravimetric-seismic modeling; problems......, the inspiration comes from the practical modeling problems in the area of Jutland peninsula (Denmark). More specifically, the methodological aspects of the proposed inversion method are illustrated on a problem of 3D modeling of the intra crustal intrusion associated with the Silkeborg Gravity High. The existing...... refraction seismic profile locates the source of the anomaly in depths 10 km - 18 km. In an earlier publication, (Strykowski, 1998), and for the same test area, a method of complex geological stripping is described. The present contribution is a continuation of this paper in the direction of inversion...

  13. Uncertainty associated with assessing semen volume: are volumetric and gravimetric methods that different?

    Science.gov (United States)

    Woodward, Bryan; Gossen, Nicole; Meadows, Jessica; Tomlinson, Mathew

    2016-12-01

    The World Health Organization laboratory manual for the examination of human semen suggests that an indirect measurement of semen volume by weighing (gravimetric method) is more accurate than a direct measure using a serological pipette. A series of experiments were performed to determine the level of discrepancy between the two methods using pipettes and a balance which had been calibrated to a traceable standard. The median weights of 1.0ml and 5.0ml of semen were 1.03 g (range 1.02-1.05 g) and 5.11 g (range 4.95-5.16 g), respectively, suggesting a density for semen between 1.03g and 1.04 g/ml. When the containers were re-weighed after the removal of 5.0 ml semen using a serological pipette, the mean residual loss was 0.12 ml (120 μl) or 0.12 g (median 100 μl, range 70-300 μl). Direct comparison of the volumetric and gravimetric methods in a total of 40 samples showed a mean difference of 0.25ml (median 0.32 ± 0.67ml) representing an error of 8.5%. Residual semen left in the container by weight was on average 0.11 g (median 0.10 g, range 0.05-0.19 g). Assuming a density of 1 g/ml then the average error between volumetric and gravimetric methods was approximately 8% (p gravimetric measurement of semen volume. Laboratories may therefore prefer to provide in-house quality assurance data in order to be satisfied that 'estimating' semen volume is 'fit for purpose' as opposed to assuming a lower uncertainty associated with the WHO recommended method.

  14. Osmotic and activity coefficients in the binary solutions of 1-butyl-3-methylimidazolium chloride and bromide in methanol or ethanol at T = 298.15 K from isopiestic measurements

    International Nuclear Information System (INIS)

    Sardroodi, Jaber Jahanbin; Azamat, Jafar; Atabay, Maryam

    2011-01-01

    Highlights: → The osmotic coefficients of the solutions of 1-butyl-3-methylimidazolium chloride and bromide in ethanol and methanol have been measured. → Measured osmotic coefficients were correlated using NRTL and Pitzer models. → Vapor pressures were evaluated from the correlated osmotic coefficients. → Model parameters have been interpreted in terms of ion-ion and ion-solvent interactions. - Abstract: Osmotic coefficients of the binary solutions of two room-temperature ionic liquids (1-butyl-3-methylimidazolium chloride and bromide) in methanol and ethanol have been measured at T = 298.15 K by the isopiestic method. The experimental osmotic coefficient data have been correlated using a forth-order polynomial in terms of (molality) 0.5 , with both, ion interaction model of Pitzer and electrolyte non-random two liquid (e-NRTL) model of Chen. The values of vapor pressures of above-mentioned solutions have been calculated from the osmotic coefficients. The model parameters fitted to the experimental osmotic coefficients have been used for prediction of the mean ionic activity coefficients of those ionic liquids in methanol and ethanol.

  15. Comparison of Metal-on-Metal Hip Simulator Wear Measured by Gravimetric, CMM and Optical Profiling Methods

    OpenAIRE

    Alberts, Larry Russell; Martinez-Nogues, Vanesa; Cook, Richard; Maul, Christian; Bills, Paul J.; Racasan, Radu; Stolz, Martin; Wood, Robert J. K.

    2018-01-01

    Simulation of wear in artificial joint implants is critical for evaluating implant designs and materials. Traditional protocols employ the gravimetric method to determine the loss of material by measuring the weight of the implant components before and after various test intervals and after the completed test. However, the gravimetric method cannot identify the location, area coverage or maximum depth of the wear and it has difficulties with proportionally small weight changes in relatively h...

  16. Erosion of water-based cements evaluated by volumetric and gravimetric methods.

    Science.gov (United States)

    Nomoto, Rie; Uchida, Keiko; Momoi, Yasuko; McCabe, John F

    2003-05-01

    To compare the erosion of glass ionomer, zinc phosphate and polycarboxylate cements using volumetric and gravimetric methods. For the volumetric method, the eroded depth of cement placed in a cylindrical cavity in PMMA was measured using a dial gauge after immersion in an eroding solution. For the gravimetric method, the weight of the residue of a solution in which a cylindrical specimen had been immersed was measured. 0.02 M lactic acid solution (0.02 M acid) and 0.1 M lactic acid/sodium lactate buffer solution (0.1 M buffer) were used as eroding solutions. The pH of both solutions was 2.74 and the test period was 24 h. Ranking of eroded depth and weight of residue was polycarboxylate>zinc phosphate>glass ionomers. Differences in erosion were more clearly defined by differences in eroded depth than differences in weight of residue. In 0.02 M acid, the erosion of glass ionomer using the volumetric method was effected by the hygroscopic expansion. In 0.1 M buffer, the erosion for polycarboxylate and zinc phosphate using the volumetric method was much greater than that using the gravimetric method. This is explained by cryo-SEM images which show many holes in the surface of specimens after erosion. It appears that zinc oxide is dissolved leaving a spongy matrix which easily collapses under the force applied to the dial gauge during measurement. The volumetric method that employs eroded depth of cement using a 0.1 M buffer solution is able to quantify erosion and to make material comparisons.

  17. Crustal thickness of Antarctica estimated using data from gravimetric satellites

    Science.gov (United States)

    Llubes, Muriel; Seoane, Lucia; Bruinsma, Sean; Rémy, Frédérique

    2018-04-01

    Computing a better crustal thickness model is still a necessary improvement in Antarctica. In this remote continent where almost all the bedrock is covered by the ice sheet, seismic investigations do not reach a sufficient spatial resolution for geological and geophysical purposes. Here, we present a global map of Antarctic crustal thickness computed from space gravity observations. The DIR5 gravity field model, built from GOCE and GRACE gravimetric data, is inverted with the Parker-Oldenburg iterative algorithm. The BEDMAP products are used to estimate the gravity effect of the ice and the rocky surface. Our result is compared to crustal thickness calculated from seismological studies and the CRUST1.0 and AN1 models. Although the CRUST1.0 model shows a very good agreement with ours, its spatial resolution is larger than the one we obtain with gravimetric data. Finally, we compute a model in which the crust-mantle density contrast is adjusted to fit the Moho depth from the CRUST1.0 model. In East Antarctica, the resulting density contrast clearly shows higher values than in West Antarctica.

  18. Use of sulfoxides for extraction-gravimetric determination of niobium and tantalum

    International Nuclear Information System (INIS)

    Nikolaev, A.I.; Babkin, A.G.; Tkachenko, V.G.

    1977-01-01

    An extraction-gravimetrical technique has been developed for determination of niobium and tantalum. The technique permits simultaneous extraction of tantalum and its concentrating in the aqueous phase; the range of Ta concentrations determined is essentially wider than in case of the routine gravimetric methods. The technique is based upon the fact, that tantalum is extracted by sulfoxides from fluorine-sulphate solutions at lower concentration of Hf and at lower ratios between the volumes of organic and aqueous phases than niobium. Two subsequent extractions by 1M sulfoxide solutions provide for practically complete transfer of tantalum into the organic phase, whereas extraction of niobium is only 3-20%. Sufficient recovery of Ta and Nb from organic phases is provided by re-extraction by NH 4 F solution. The technique is suitable for niobium and tantalum determination at the ratios of their pentoxides from 1:100 to 100:1. The disturbing influence of Fe(3) is suppressed by reductions to Fe(2)

  19. Gravimetric determination of uranium(VI) and thorium(IV) with substituted pyrazolones

    International Nuclear Information System (INIS)

    Arora, H.C.; Rao, G.N.

    1981-01-01

    4-Acylpyrazolones like 1-phenyl-3-methyl-4-benzoyl-5-pyrazolone (PMBP), 1-phenyl-3-methyl-4-p-nitrobenzoyl-5-pyrazolone (PMNP) and 1-phenyl-3-methyl-4-(3,5 dinitrobenzoyl)-5-pyrazolone (PMDP) have been synthesized and developed as gravimetric reagents for the determination of U(VI) and Th(IV). Uranium(VI) is almost quantitatively precipitated with PMBP, PMNP, and PMDP at pH 2.20, 1.85 and 1.70 respectively. The pH values for the complete precipitation of thorium(IV) with PMBP, PMNP and PMDP are 2.90, 2.75 and 2.50 respectively. PMBP has proved to be an efficient ligand for gravimetric determination of U(VI) by direct weighing method after drying at 100 +- 10 deg C. The percentage relative error varies from 0.4 to 1.6 in the determination of U(VI) by this method. The effect of a number of interfering ions on the precipitation of U(VI) by PMBP has been reported. (author)

  20. Semiconductor apparatus and method of fabrication for a semiconductor apparatus

    NARCIS (Netherlands)

    2010-01-01

    The invention relates to a semiconductor apparatus (1) and a method of fabrication for a semiconductor apparatus (1), wherein the semiconductor apparatus (1) comprises a semiconductor layer (2) and a passivation layer (3), arranged on a surface of the semiconductor layer (2), for passivating the

  1. Determining the better solvent and time for extracting soil by soxhlet in TPH (Total Petroleum Hydrocarbon) gravimetric method; A determinacao de qual o melhor solvente e o melhor tempo de extracao de sedimento em aparato Soxhlet na metodologia do TPH (Total Petroleum Hydrocarbon) gravimetrico

    Energy Technology Data Exchange (ETDEWEB)

    Koike, Renato S.; Lima, Guilherme; Baisch, Paulo R. [Fundacao Universidade Federal do Rio Grande (FURG), RS (Brazil)

    2004-07-01

    There are several methods of TPH (Total Petroleum Hydrocarbons) analysis of petroleum hydrocarbons contaminants in sediment. The TPH gravimetric has been widely used in many studies and in oil spill monitoring case. The present work examined three different solvents (DCM, DCM/N-HEX and N-HEX), in three different times, to the purpose to optimize the contaminants extraction using USEPA 9071 and 3540 reference method. Then was realized analysis of Total Organic Carbon (TOC) for monitoring the reproducible extracts. The sediments used in this experiment was collected in the Cavalos Island, localized in the city of Rio Grande, RS-Brasil. The sediment was 'washed' and after then contaminated with petroleum. The extracts were realized in Soxhlet apparatus, in three different times (4, 8 and 12 hours), and TOC analysis were realized before and after the extraction. The result demonstrated that eight hours with DCM/N-HEX solvent is more indicated for TPH gravimetric in sediment analysis with high concentration of petroleum hydrocarbons. TOC analysis demonstrated inappropriate for monitoring extract reproducibility. (author)

  2. Humidity and Gravimetric Equivalency Adjustments for Nephelometer-Based Particulate Matter Measurements of Emissions from Solid Biomass Fuel Use in Cookstoves

    Science.gov (United States)

    Soneja, Sutyajeet; Chen, Chen; Tielsch, James M.; Katz, Joanne; Zeger, Scott L.; Checkley, William; Curriero, Frank C.; Breysse, Patrick N.

    2014-01-01

    Great uncertainty exists around indoor biomass burning exposure-disease relationships due to lack of detailed exposure data in large health outcome studies. Passive nephelometers can be used to estimate high particulate matter (PM) concentrations during cooking in low resource environments. Since passive nephelometers do not have a collection filter they are not subject to sampler overload. Nephelometric concentration readings can be biased due to particle growth in high humid environments and differences in compositional and size dependent aerosol characteristics. This paper explores relative humidity (RH) and gravimetric equivalency adjustment approaches to be used for the pDR-1000 used to assess indoor PM concentrations for a cookstove intervention trial in Nepal. Three approaches to humidity adjustment performed equivalently (similar root mean squared error). For gravimetric conversion, the new linear regression equation with log-transformed variables performed better than the traditional linear equation. In addition, gravimetric conversion equations utilizing a spline or quadratic term were examined. We propose a humidity adjustment equation encompassing the entire RH range instead of adjusting for RH above an arbitrary 60% threshold. Furthermore, we propose new integrated RH and gravimetric conversion methods because they have one response variable (gravimetric PM2.5 concentration), do not contain an RH threshold, and is straightforward. PMID:24950062

  3. Humidity and gravimetric equivalency adjustments for nephelometer-based particulate matter measurements of emissions from solid biomass fuel use in cookstoves.

    Science.gov (United States)

    Soneja, Sutyajeet; Chen, Chen; Tielsch, James M; Katz, Joanne; Zeger, Scott L; Checkley, William; Curriero, Frank C; Breysse, Patrick N

    2014-06-19

    Great uncertainty exists around indoor biomass burning exposure-disease relationships due to lack of detailed exposure data in large health outcome studies. Passive nephelometers can be used to estimate high particulate matter (PM) concentrations during cooking in low resource environments. Since passive nephelometers do not have a collection filter they are not subject to sampler overload. Nephelometric concentration readings can be biased due to particle growth in high humid environments and differences in compositional and size dependent aerosol characteristics. This paper explores relative humidity (RH) and gravimetric equivalency adjustment approaches to be used for the pDR-1000 used to assess indoor PM concentrations for a cookstove intervention trial in Nepal. Three approaches to humidity adjustment performed equivalently (similar root mean squared error). For gravimetric conversion, the new linear regression equation with log-transformed variables performed better than the traditional linear equation. In addition, gravimetric conversion equations utilizing a spline or quadratic term were examined. We propose a humidity adjustment equation encompassing the entire RH range instead of adjusting for RH above an arbitrary 60% threshold. Furthermore, we propose new integrated RH and gravimetric conversion methods because they have one response variable (gravimetric PM2.5 concentration), do not contain an RH threshold, and is straightforward.

  4. Visual estimation versus gravimetric measurement of postpartum blood loss: a prospective cohort study.

    Science.gov (United States)

    Al Kadri, Hanan M F; Al Anazi, Bedayah K; Tamim, Hani M

    2011-06-01

    One of the major problems in international literature is how to measure postpartum blood loss with accuracy. We aimed in this research to assess the accuracy of visual estimation of postpartum blood loss (by each of two main health-care providers) compared with the gravimetric calculation method. We carried out a prospective cohort study at King Abdulaziz Medical City, Riyadh, Saudi Arabia between 1 November 2009 and 31 December 2009. All women who were admitted to labor and delivery suite and delivered vaginally were included in the study. Postpartum blood loss was visually estimated by the attending physician and obstetrics nurse and then objectively calculated by a gravimetric machine. Comparison between the three methods of blood loss calculation was carried out. A total of 150 patients were included in this study. There was a significant difference between the gravimetric calculated blood loss and both health-care providers' estimation with a tendency to underestimate the loss by about 30%. The background and seniority of the assessing health-care provider did not affect the accuracy of the estimation. The corrected incidence of postpartum hemorrhage in Saudi Arabia was found to be 1.47%. Health-care providers tend to underestimate the volume of postpartum blood loss by about 30%. Training and continuous auditing of the diagnosis of postpartum hemorrhage is needed to avoid missing cases and thus preventing associated morbidity and mortality.

  5. Crustal thickness of Antarctica estimated using data from gravimetric satellites

    Directory of Open Access Journals (Sweden)

    M. Llubes

    2018-04-01

    Full Text Available Computing a better crustal thickness model is still a necessary improvement in Antarctica. In this remote continent where almost all the bedrock is covered by the ice sheet, seismic investigations do not reach a sufficient spatial resolution for geological and geophysical purposes. Here, we present a global map of Antarctic crustal thickness computed from space gravity observations. The DIR5 gravity field model, built from GOCE and GRACE gravimetric data, is inverted with the Parker–Oldenburg iterative algorithm. The BEDMAP products are used to estimate the gravity effect of the ice and the rocky surface. Our result is compared to crustal thickness calculated from seismological studies and the CRUST1.0 and AN1 models. Although the CRUST1.0 model shows a very good agreement with ours, its spatial resolution is larger than the one we obtain with gravimetric data. Finally, we compute a model in which the crust–mantle density contrast is adjusted to fit the Moho depth from the CRUST1.0 model. In East Antarctica, the resulting density contrast clearly shows higher values than in West Antarctica.

  6. Strategy for thermo-gravimetric analysis of K East fuel samples

    International Nuclear Information System (INIS)

    Lawrence, L.A.

    1997-01-01

    A strategy was developed for the Thermo-Gravimetric Analysis (TGA) testing of K East fuel samples for oxidation rate determinations. Tests will first establish if there are any differences for dry air oxidation between the K West and K East fuel. These tests will be followed by moist inert gas oxidation rate measurements. The final series of tests will consider pure water vapor i.e., steam

  7. Comparison of neutron scattering, gravimetric and tensiometric methods for measuring soil water content in the field

    International Nuclear Information System (INIS)

    Jat, R.L.; Das, D.K.; Naskar, G.C.

    1975-01-01

    Water content of a sandy clay loam soil was measured by neutron scattering, gravimetric and tensiometric methods. Tensiometric measurement based on laboratory moisture retention curve gave comparatively higher moisture content than those obtained by other methods. No significant differences were observed among neutron meter, gravimetric and tensiometric measurement based on field calibration curve. Though for irrigation purposes all the methods can be used equally, use of tensiometric method with field calibration curve is suggested for easy and more accurate soil water content measurement where neutron meter is not available. (author)

  8. Control and Prediction of the Course of Brewery Fermentations by Gravimetric Analysis

    Czech Academy of Sciences Publication Activity Database

    Košín, P.; Šavel, J.; Brož, A.; Sigler, Karel

    2008-01-01

    Roč. 53, č. 5 (2008), s. 451-456 ISSN 0015-5632 R&D Projects: GA MŠk 1M0570 Institutional research plan: CEZ:AV0Z50200510 Keywords : brewery fermentation * gravimetric analysis Subject RIV: EE - Microbiology, Virology Impact factor: 1.172, year: 2008

  9. Gravimetric Model of Quasigeoid in the Area of Slovakia

    Directory of Open Access Journals (Sweden)

    Juraj Papčo

    2005-06-01

    Full Text Available The gravimetric model of quasigeoid in the area of Slovakia was determined by using the revised and homogenised gravity mapping data in the scale of 1:25 000 from the area of Slovakia, and by using the mean Bouguer gravity anomalies with the resolution of 5´x7.5´ in the area 44°<φ<56° and 12°<λ<30° from abroad and by the digital terrain model DMR-2/ERTS89 with the resolution 3“ in the ellipsoidal latitude and 5“ in the ellipsoidal longitude from the area of Slovakia and the digital terrain model GTOPO30 with the resolution of 30“ in the ellipsoidal latitude and 30“ in the ellipsoidal longitude from abroad. The global part of the height anomaly was determined from the global geopotential model EGM96. The residual part of the height anomaly was determined by the Stokes integral formula. For the solution of the Stokes integra,l the Fast Fourier Transformation method in the spherical approximation was used. The gravimetric quasigeoid was tested by the GPS/levelling method using 46 points distributed on the area of Slovakia. The systematic trend of differences between height anomalies was rejected by the surface polynomial of second degree with 6 coefficients. The standard deviation after removing a systematic trend was 0.017 m

  10. ROLLER FILTRATION APPARATUS

    DEFF Research Database (Denmark)

    2017-01-01

    The present invention relates to the field of filtering, more precisely the present invention concerns an apparatus and a method for the separation of dry matter from a medium and the use of said apparatus. One embodiment discloses an apparatus for the separation of dry matter and liquid from a m...

  11. Multipactor discharge apparatus

    International Nuclear Information System (INIS)

    1976-01-01

    The invention deals with a multipactor discharge apparatus which can be used for tuning microwave organs such as magnetron oscillators and other cavity resonators. This apparatus is suitable for delivering an improved tuning effect in a resonation organ wherefrom the working frequency must be set. This apparatus is equipped with two multipactor discharge electrodes set in a configuration such to that a net current flows from one electrode to another. These electrodes are parallel and flat. The apparatus can be used in magnetron devices as well for continuous waves as for impulses

  12. A Comparative Analysis of Seismological and Gravimetric Crustal Thicknesses below the Andean Region with Flat Subduction of the Nazca Plate

    Directory of Open Access Journals (Sweden)

    Mario E. Gimenez

    2009-01-01

    Full Text Available A gravimetric study was carried out in a region of the Central Andean Range between 28∘ and 32∘ south latitudes and from 72∘ and 66∘ west longitudes. The seismological and gravimetrical Moho models were compared in a sector which coincides with the seismological stations of the CHARGE project. The comparison reveals discrepancies between the gravity Moho depths and those obtained from seismological investigations (CHARGE project, the latter giving deeper values than those resulting from the gravimetric inversion. These discrepancies are attenuated when the positive gravimetric effect of the Nazca plate is considered. Nonetheless, a small residuum of about 5 km remains beneath the Cuyania terrane region, to the east of the main Andean chain. This residuum could be gravimetrically justified if the existence of a high density or eclogitized portion of the lower crust is considered. This result differed from the interpretations from Project “CHARGE” which revealed that the entire inferior crust extending from the Precordillera to the occidental “Sierras Pampeanas” could be “eclogitized”. In this same sector, we calculated the effective elastic thickness (Te of the crust. These results indicated an anomalous value of Te = 30 km below the Cuyania terrane. This is further conclusive evidence of the fact that the Cuyania terrane is allochthonous, for which also geological evidences exist.

  13. Gamma tomography apparatus

    International Nuclear Information System (INIS)

    Span, F.J.

    1988-01-01

    The patent concerns a gamma tomography apparatus for medical diagnosis. The apparatus comprises a gamma scintillation camera head and a suspension system for supporting and positioning the camera head with respect for the patient. Both total body scanning and single photon emission tomography can be carried out with the apparatus. (U.K.)

  14. Novel gravimetric measurement technique for quantitative volume calibration in the sub-microliter range

    International Nuclear Information System (INIS)

    Liang, Dong; Zengerle, Roland; Steinert, Chris; Ernst, Andreas; Koltay, Peter; Bammesberger, Stefan; Tanguy, Laurent

    2013-01-01

    We present a novel measurement method based on the gravimetric principles adapted from the ASTM E542 and ISO 4787 standards for quantitative volume determination in the sub-microliter range. Such a method is particularly important for the calibration of non-contact micro dispensers as well as other microfluidic devices. The novel method is based on the linear regression analysis of continuously monitored gravimetric results and therefore is referred to as ‘gravimetric regression method (GRM)’. In this context, the regression analysis is necessary to compensate the mass loss due to evaporation that is significant for very small dispensing volumes. A full assessment of the measurement uncertainty of GRM is presented and results in a standard measurement uncertainty around 6 nl for dosage volumes in the range from 40 nl to 1 µl. The GRM has been experimentally benchmarked with a dual-dye ratiometric photometric method (Artel Inc., Westbrook, ME, USA), which can provide traceability of measurement to the International System of Units (SI) through reference standards maintained by NIST. Good precision (max. CV = 2.8%) and consistency (bias around 7 nl in the volume range from 40 to 400 nl) have been observed comparing the two methods. Based on the ASTM and ISO standards on the one hand and the benchmark with the photometric method on the other hand, two different approaches for establishing traceability for the GRM are discussed. (paper)

  15. Comparison of gravimetric, creamatocrit and esterified fatty acid methods for determination of total fat content in human milk.

    Science.gov (United States)

    Du, Jian; Gay, Melvin C L; Lai, Ching Tat; Trengove, Robert D; Hartmann, Peter E; Geddes, Donna T

    2017-02-15

    The gravimetric method is considered the gold standard for measuring the fat content of human milk. However, it is labor intensive and requires large volumes of human milk. Other methods, such as creamatocrit and esterified fatty acid assay (EFA), have also been used widely in fat analysis. However, these methods have not been compared concurrently with the gravimetric method. Comparison of the three methods was conducted with human milk of varying fat content. Correlations between these methods were high (r(2)=0.99). Statistical differences (Pmethods. Overall, stronger correlation with lower mean (4.73g/L) and percentage differences (5.16%) was observed with the creamatocrit than the EFA method when compared to the gravimetric method. Furthermore, the ease of operation and real-time analysis make the creamatocrit method preferable. Copyright © 2016. Published by Elsevier Ltd.

  16. Precision gravimetric survey at the conditions of urban agglomerations

    Science.gov (United States)

    Sokolova, Tatiana; Lygin, Ivan; Fadeev, Alexander

    2014-05-01

    Large cities growth and aging lead to the irreversible negative changes of underground. The study of these changes at the urban area mainly based on the shallow methods of Geophysics, which extensive usage restricted by technogenic noise. Among others, precision gravimetry is allocated as method with good resistance to the urban noises. The main the objects of urban gravimetric survey are the soil decompaction, leaded to the rocks strength violation and the karst formation. Their gravity effects are too small, therefore investigation requires the modern high-precision equipment and special methods of measurements. The Gravimetry division of Lomonosov Moscow State University examin of modern precision gravimeters Scintrex CG-5 Autograv since 2006. The main performance characteristics of over 20 precision gravimeters were examined in various operational modes. Stationary mode. Long-term gravimetric measurements were carried at a base station. It shows that records obtained differ by high-frequency and mid-frequency (period 5 - 12 hours) components. The high-frequency component, determined as a standard deviation of measurement, characterizes the level of the system sensitivity to external noise and varies for different devices from 2 to 5-7 μGals. Midrange component, which closely meet to the rest of nonlinearity gravimeter drifts, is partially compensated by the equipment. This factor is very important in the case of gravimetric monitoring or observations, when midrange anomalies are the target ones. For the examined gravimeters, amplitudes' deviations, associated with this parameter may reach 10 μGals. Various transportation modes - were performed by walking (softest mode), lift (vertical overload), vehicle (horizontal overloads), boat (vertical plus horizontal overloads) and helicopter. The survey quality was compared by the variance of the measurement results and internal convergence of series. The measurement results variance (from ±2 to ±4 μGals) and its

  17. Study of the corrosion behavior of magnesium alloy weddings in NaCl solutions by gravimetric tests

    Energy Technology Data Exchange (ETDEWEB)

    Segarra, J. A.; Calderon, B.; Portoles, A.

    2015-07-01

    In this article, the corrosion behavior of commercial AZ31 welded plates in aqueous chloride media was investigated by means of gravimetric techniques and Neutral Salt Spray tests (NSS). The AZ31 samples tested were welded using Gas Tugsten Arc Welding (GTAW) and different filler materials. Material microstructures were investigated by optical microscopy to stablish the influence of those microstructures in the corrosion behavior. Gravimetric and NSS tests indicate that the use of more noble filler alloys for the sample welding, preventing the reduction of aluminum content in weld beads, does not imply a better corrosion behavior. (Author)

  18. A detailed gravimetric geoid of North America, the North Atlantic, Eurasia, and Australia

    Science.gov (United States)

    Marsh, J. G.

    1973-01-01

    A computer program was developed for the calculation of a goid based upon a combination of satellite and surface gravity data. A detailed gravimetric geoid of North America, the North Atlantic, Eurasia, and Australia was derived by using this program.

  19. Comparison of the gravimetric, phenol red, and 14C-PEG-3350 methods to determine water absorption in the rat single-pass intestinal perfusion model.

    Science.gov (United States)

    Sutton, S C; Rinaldi, M T; Vukovinsky, K E

    2001-01-01

    This study was undertaken to determine whether the gravimetric method provided an accurate measure of water flux correction and to compare the gravimetric method with methods that employ nonabsorbed markers (eg, phenol red and 14C-PEG-3350). Phenol red,14C-PEG-3350, and 4-[2-[[2-(6-amino-3-pyridinyl)-2-hydroxyethyl]amino]ethoxy]-, methyl ester, (R)-benzene acetic acid (Compound I) were co-perfused in situ through the jejunum of 9 anesthetized rats (single-pass intestinal perfusion [SPIP]). Water absorption was determined from the phenol red,14C-PEG-3350, and gravimetric methods. The absorption rate constant (ka) for Compound I was calculated. Both phenol red and 14C-PEG-3350 were appreciably absorbed, underestimating the extent of water flux in the SPIP model. The average +/- SD water flux microg/h/cm) for the 3 methods were 68.9 +/- 28.2 (gravimetric), 26.8 +/- 49.2 (phenol red), and 34.9 +/- 21.9 (14C-PEG-3350). The (average +/- SD) ka for Compound I (uncorrected for water flux) was 0.024 +/- 0.005 min(-1). For the corrected, gravimetric method, the average +/- SD was 0.031 +/- 0.001 min(-1). The gravimetric method for correcting water flux was as accurate as the 2 "nonabsorbed" marker methods.

  20. Gravimetric method for in vitro calibration of skin hydration measurements.

    Science.gov (United States)

    Martinsen, Ørjan G; Grimnes, Sverre; Nilsen, Jon K; Tronstad, Christian; Jang, Wooyoung; Kim, Hongsig; Shin, Kunsoo; Naderi, Majid; Thielmann, Frank

    2008-02-01

    A novel method for in vitro calibration of skin hydration measurements is presented. The method combines gravimetric and electrical measurements and reveals an exponential dependency of measured electrical susceptance to absolute water content in the epidermal stratum corneum. The results also show that absorption of water into the stratum corneum exhibits three different phases with significant differences in absorption time constant. These phases probably correspond to bound, loosely bound, and bulk water.

  1. Separation and gravimetric determination of rare earths with N-(3-nitrobenzoyl), N-(3-tolyl) hydroxylamine

    International Nuclear Information System (INIS)

    Agrawal, Y.K.; Kapoor, H.L.

    1977-01-01

    The N-(3-nitrobenzoyl), N-(3-tolyl) hydroxylamine is used as a reagent for the separation and gravimetric determination of Ce 3+ , La 3+ , Pr 3+ , Nd 3+ , Sm 3+ and Gd 3+ . The optimum conditions of precipitation of these rare earths indicate that, by control of pH and judicious use of masking agents, these ions can be separated from, and determined gravimetrically among several other ions. Further, the stochiometric nature of the N-(3-nitrobenzoyl), N-(3-tolyl) hydroxylamine acid is advantageous for the direct determination by weighting of (C 14 H 11 N 2 O 4 ) 3 M complex without ignition to obtain oxides. These complexes are characterized by infrared spectra

  2. Gravimetric determination of cadmium with o-phenanthroline and iodide

    International Nuclear Information System (INIS)

    Yoshida, Hitoshi; Mizuno, Kazunori; Taga, Mitsuhiko; Hikime, Seiichiro

    1976-01-01

    Cadmium forms insoluble mixed ligand complex with o-phenanthroline and iodide ions. By using the complex a new gravimetric method for the determination of cadmium was investigated. The recommended analytical procedure is as follows: Adjust pH value of a solution containing 5 to 45 mg cadmium to 4 with 3 M acetic acid-sodium acetate buffer solution. Add over threefold moles of potassium iodide to the solution and heat to just before boiling. To the solution add 0.1% ascorbic acid solution and then 0.1 M o-phenanthroline solution drop by drop in excess with stirring, and cool the mixture to room temperature. Filter the precipitates and wash first with 0.01% potassium iodide solution and then with water. Dry the precipitates at 110 0 C for two hours and weigh as Cd(o-phen) 2 I 2 (I). The gravimetric factor of the complex for cadmium is 0.1547. Chemical composition of the precipitate is variable when o-phenanthroline is added less than twofold moles to cadmium. Adding the o-phenanthroline solution 2.4-fold moles against cadmium, the ternary complex (I) precipitates quantitatively. Though a large excess of iodide ion in the solution contaminated the precipitate, the contamination was avoided when precipitation was carryed out at high temperature and in the presence of ascorbic acid. By the presented procedure 5 to 45 mg of cadmium are determined with a standard deviation of 0 C. (JPN)

  3. Computation of improved tidal parameters at the gravimetric station of Brasimone

    Directory of Open Access Journals (Sweden)

    P. Baldi

    1997-06-01

    Full Text Available Since 1991 a GWR superconducting gravimeter has been working in a laboratory at the Brasimone ENEA Research Centre, near Bologna (Italy, in the frame of an experimental program to verify Newton's law over distances of the order of 10-100 m. Owing to the aim of the experiment, the gravimeter was moved to different laboratories in the same area, but from August 1995 to date it has been working continuously in the same laboratory in the frame of the preliminary program of the Global Geodynamics Project. The site, belonging to a building of a dismissed nuclear power plant, is free from noise due to human activities, and is thus highly suitable for recording Earth tides. Starting from a set of gravimetric and atmospheric pressure data of high quality relative to 22 months of observation, we performed the tidal analysis using Eterna 3.2 software in order to compute amplitudes, gravimetric factors and phases of the main waves of the Tamura 1987 catalogue. The accuracy of the method adopted for the calibration of the gravimeter, the values of the principal waves and the result of the computation of atmospheric pressure admittance are described.

  4. Mycotoxin metrology: Gravimetric production of zearalenone calibration solution

    Science.gov (United States)

    Rego, E. C. P.; Simon, M. E.; Li, Xiuqin; Li, Xiaomin; Daireaux, A.; Choteau, T.; Westwood, S.; Josephs, R. D.; Wielgosz, R. I.; Cunha, V. S.

    2018-03-01

    Food safety is a major concern for countries developing metrology and quality assurance systems, including the contamination of food and feed by mycotoxins. To improve the mycotoxin analysis and ensure the metrological traceability, CRM of calibration solution should be used. The production of certified mycotoxin solutions is a major challenge due to the limited amount of standard for conducting a proper purity study and due to the cost of standards. The CBKT project was started at BIPM and Inmetro produced gravimetrically one batch of zearelenone in acetronitrile (14.708 ± 0.016 μg/g, k=2) and conducted homogeneity, stability and value assignment studies.

  5. Borehole sealing method and apparatus

    International Nuclear Information System (INIS)

    Hartley, J.N.; Jansen, G. Jr.

    1977-01-01

    A method and apparatus is described for sealing boreholes in the earth. The borehole is blocked at the sealing level, and a sealing apparatus capable of melting rock and earth is positioned in the borehole just above seal level. The apparatus is heated to rock-melting temperature and powdered rock or other sealing material is transported down the borehole to the apparatus where it is melted, pooling on the mechanical block and allowed to cool and solidify, sealing the hole. Any length of the borehole can be sealed by slowly raising the apparatus in the borehole while continuously supplying powdered rock to the apparatus to be melted and added to the top of the column of molten and cooling rock, forming a continuous borehole seal. The sealing apparatus consists of a heater capable of melting rock, including means for supplying power to the heater, means for transporting powdered rock down the borehole to the heater, means for cooling the apparatus and means for positioning the apparatus in the borehole. 5 claims, 1 figure

  6. A highly accurate absolute gravimetric network for Albania, Kosovo and Montenegro

    Science.gov (United States)

    Ullrich, Christian; Ruess, Diethard; Butta, Hubert; Qirko, Kristaq; Pavicevic, Bozidar; Murat, Meha

    2016-04-01

    The objective of this project is to establish a basic gravity network in Albania, Kosovo and Montenegro to enable further investigations in geodetic and geophysical issues. Therefore the first time in history absolute gravity measurements were performed in these countries. The Norwegian mapping authority Kartverket is assisting the national mapping authorities in Kosovo (KCA) (Kosovo Cadastral Agency - Agjencia Kadastrale e Kosovës), Albania (ASIG) (Autoriteti Shtetëror i Informacionit Gjeohapësinor) and in Montenegro (REA) (Real Estate Administration of Montenegro - Uprava za nekretnine Crne Gore) in improving the geodetic frameworks. The gravity measurements are funded by Kartverket. The absolute gravimetric measurements were performed from BEV (Federal Office of Metrology and Surveying) with the absolute gravimeter FG5-242. As a national metrology institute (NMI) the Metrology Service of the BEV maintains the national standards for the realisation of the legal units of measurement and ensures their international equivalence and recognition. Laser and clock of the absolute gravimeter were calibrated before and after the measurements. The absolute gravimetric survey was carried out from September to October 2015. Finally all 8 scheduled stations were successfully measured: there are three stations located in Montenegro, two stations in Kosovo and three stations in Albania. The stations are distributed over the countries to establish a gravity network for each country. The vertical gradients were measured at all 8 stations with the relative gravimeter Scintrex CG5. The high class quality of some absolute gravity stations can be used for gravity monitoring activities in future. The measurement uncertainties of the absolute gravity measurements range around 2.5 micro Gal at all stations (1 microgal = 10-8 m/s2). In Montenegro the large gravity difference of 200 MilliGal between station Zabljak and Podgorica can be even used for calibration of relative gravimeters

  7. Evaluation of the gravimetric tetraphenylarsonium method for the determination of Tc(VII)

    International Nuclear Information System (INIS)

    Pacer, R.A.

    1980-01-01

    Solubility losses in the gravimetric tetraphenylarsonium method for determining pertechnetate have been evaluated. Liquid scintillation counting was used to measure the β - activity of 99 Tc in the filtrate, and indicated solubility losses of about 1% in analyses yielding 40 to 50 mg of precipitate. The solubility product of (C 6 H 5 ) 4 AsTcO 4 is estimated to be (8.6 +- 0.2) x 10 -10 at room temperature (24 to 25 0 ), and Ksub(sp) for (C 6 H 5 ) 4 AsReO 4 at approximately 21 to 23 0 is estimated at (2.6 +- 0.3) x 10 -9 . Both values are satisfactory for gravimetric purposes, but to keep solubility losses within 1% at least 40 mg of (C 6 H 5 ) 4 AsTcO 4 or 80 mg of (C 6 H 5 ) 4 AsReO 4 should be obtained (assuming 20 ml of solution, 20 to 30% excess of precipitant, and 6 or 7 washes with 5-ml portions of distilled water). (author)

  8. Apparatus for drying sugar cubes

    NARCIS (Netherlands)

    Derckx, H.A.J.; Torringa, H.M.

    1999-01-01

    Device for drying sugar cubes containing a heating apparatus for heating and dehumidifying the sugar cubes, a conditioning apparatus for cooling off and possibly further dehumidifying the sugar cubes and a conveying apparatus for conveying the sugar cubes through the heating apparatus and the

  9. Estimation of the internal structure of Trans-Mexican volcanic belt by gravimetric data

    International Nuclear Information System (INIS)

    Flores R, J.H.

    1994-01-01

    The regional gravimetric data of Trans-Mexican volcanic belt and surroundings, has been analyzed in order to estimate the depth of its internal structure. The short profiles with N-S orientation give a model of four shells with an average depth in the rank 24, 34, 56 and 83 kilometers. Only the profiles included between 97 West degrees to 102 West degrees give a depth of crust larger than the rest of the profiles with the same orientation. This profiles are associated with that of the Valleys of Toluca, D.F. and Puebla where the maximum crust thickness was estimated. The 3 long profiles with S-W orientation, give a model of 3 shells. The tendency of the first shell has a cortical thickness of 38 kilometers in the latitude of 18 North degrees. This tendency to increase the depth in the crust is associated with the minimum gravimetric in the map of Bouguer anomaly. (Author)

  10. Magnetometric and gravimetric surveys in fault detection over Acambay System

    Science.gov (United States)

    García-Serrano, A.; Sanchez-Gonzalez, J.; Cifuentes-Nava, G.

    2013-05-01

    In commemoration of the centennial of the Acambay intraplate earthquake of November 19th 1912, we carry out gravimetric and magnetometric surveys to define the structure of faults caused by this event. The study area is located approximately 11 km south of Acambay, in the Acambay-Tixmadeje fault system, where we performed two magnetometric surveys, the first consisting of 17 lines with a spacing of 35m between lines and 5m between stations, and the second with a total of 12 lines with the same spacing, both NW. In addition to these two lines we performed gravimetric profiles located in the central part of each magnetometric survey, with a spacing of 25m between stations, in order to correlate the results of both techniques, the lengths of such profiles were of 600m and 550m respectively. This work describes the data processing including directional derivatives, analytical signal and inversion, by means of which we obtain results of magnetic variations and anomaly traits highly correlated with those faults. It is of great importance to characterize these faults given the large population growth in the area and settlement houses on them, which involves a high risk in the security of the population, considering that these are active faults and cannot be discard earthquakes associated with them, so it is necessary for the authorities and people have relevant information to these problem.

  11. Training apparatus

    International Nuclear Information System (INIS)

    Monteith, W.D.

    1983-01-01

    Training apparatus for use in contamination surveillance uses a mathematical model of a hypothetical contamination source (e.g. nuclear, bacteriological or chemical explosion or leak) to determine from input data defining the contamination source, the contamination level at any location within a defined exercise area. The contamination level to be displayed by the apparatus is corrected to real time from a real time clock or may be displayed in response to a time input from a keyboard. In a preferred embodiment the location is defined by entering UTM grid reference coordinates using the keyboard. The mathematical model used by a microprocessor of the apparatus for simulation of contamination levels in the event of a nuclear explosion is described. (author)

  12. Application, advantages and limitations of high-density gravimetric surveys compared with three-dimensional geological modelling in dolomite stability investigations

    OpenAIRE

    Breytenbach, I J; Bosch, P J A

    2011-01-01

    The article discusses the nature of the gravimetric survey as applied and used in dolomite stability investigations on areas underlain by the Chuniespoort Group in South Africa. A short discussion is given on the gravimetric survey procedure along with its uses and alternative methods. Finally, two case studies illustrate the application of the method on a high-density survey grid spacing in comparison with three-dimensional geological modelling based on the lithology and karst weathering hor...

  13. Pore roller filtration apparatus

    DEFF Research Database (Denmark)

    2014-01-01

    The present invention relates to the field of filtering, more precisely the present invention concerns an apparatus and a method for the separation of dry matter from a medium and the use of said apparatus. One embodiment discloses an apparatus for the separation of dry matter from a medium, comp...

  14. Isopiestic determination of the osmotic coefficient and vapour pressure of N-R-4-(N,N-dimethylamino)pyridinium tetrafluoroborate (R = C4H9, C5H11, C6H13) in the ethanol solution at T = 298.15 K

    International Nuclear Information System (INIS)

    Sardroodi, Jaber Jahanbin; Atabay, Maryam; Azamat, Jafar

    2012-01-01

    Highlights: ► The osmotic coefficients of the solutions of ionic liquid in ethanol have been measured. ► Measured osmotic coefficients were correlated using Pitzer, e-NRTL and NRF models and polynomial equation. ► Vapour pressures were evaluated from the correlated osmotic coefficients. - Abstract: Osmotic coefficients of the solutions of room temperature ionic liquid N-R-4-(N,N-dimethylamino)pyridinium tetrafluoroborate (R = C 4 H 9 , C 5 H 11 , C 6 H 13 ) in ethanol have been measured at T = 298.15 K by the isopiestic method. The experimental osmotic coefficients have been correlated using the ion interaction model of Pitzer, electrolyte non-random two liquid (e-NRTL) model of Chen, non-random factor (NRF) and a fourth-order polynomial in terms of molality. The vapour pressures of the solutions studied have been evaluated from the osmotic coefficients.

  15. Microelectromechanical acceleration-sensing apparatus

    Science.gov (United States)

    Lee, Robb M [Albuquerque, NM; Shul, Randy J [Albuquerque, NM; Polosky, Marc A [Albuquerque, NM; Hoke, Darren A [Albuquerque, NM; Vernon, George E [Rio Rancho, NM

    2006-12-12

    An acceleration-sensing apparatus is disclosed which includes a moveable shuttle (i.e. a suspended mass) and a latch for capturing and holding the shuttle when an acceleration event is sensed above a predetermined threshold level. The acceleration-sensing apparatus provides a switch closure upon sensing the acceleration event and remains latched in place thereafter. Examples of the acceleration-sensing apparatus are provided which are responsive to an acceleration component in a single direction (i.e. a single-sided device) or to two oppositely-directed acceleration components (i.e. a dual-sided device). A two-stage acceleration-sensing apparatus is also disclosed which can sense two acceleration events separated in time. The acceleration-sensing apparatus of the present invention has applications, for example, in an automotive airbag deployment system.

  16. Apparatus for gamma ray radiography

    International Nuclear Information System (INIS)

    Kobayashi, Masatoshi; Enomoto, Shigemasa; Oga, Hiroshi

    1979-01-01

    This is the standard of Japan Non-Destructive Inspection Society, NDIS 1101-79, which stipulates on the design, construction and testing method of the apparatuses for gamma ray radiography used for taking industrial radiograms. The gamma ray apparatuses stipulated in this standard are those containing sealed radioactive isotopes exceeding 100 μCi, which emit gamma ray. The gamma ray apparatuses are classified into three groups according to their movability. The general design conditions, the irradiation dose rate and the sealed radiation sources for the gamma ray apparatuses are stipulated. The construction of the gamma ray apparatuses must be in accordance with the notification No. 52 of the Ministry of Labor, and safety devices and collimators must be equipped. The main bodies of the gamma ray apparatuses must pass the vibration test, penetration test, impact test and shielding efficiency test. The method of each test is described. The attached equipments must be also tested. The tests according to this standard are carried out by the makers of the apparatuses. The test records must be made when the apparatuses have passed the tests, and the test certificates are attached. The limit of guarantee by the endurance test must be clearly shown. The items to be shown on the apparatuses are stipulated. (Kako, I.)

  17. Mirror plasma apparatus

    International Nuclear Information System (INIS)

    Moir, R.W.

    1981-01-01

    A mirror plasma apparatus which utilizes shielding by arc discharge to form a blanket plasma and lithium walls to reduce neutron damage to the wall of the apparatus. An embodiment involves a rotating liquid lithium blanket for a tandem mirror plasma apparatus wherein the first wall of the central mirror cell is made of liquid lithium which is spun with angular velocity great enough to keep the liquid lithium against the first material wall, a blanket plasma preventing the lithium vapor from contaminating the plasma

  18. Water intake fish diversion apparatus

    International Nuclear Information System (INIS)

    Taft, E.P. III; Cook, T.C.

    1995-01-01

    A fish diversion apparatus uses a plane screen to divert fish for variety of types of water intakes in order to protect fish from injury and death. The apparatus permits selection of a relatively small screen angle, for example ten degrees, to minimize fish injury. The apparatus permits selection of a high water velocity, for example ten feet per second, to maximize power generation efficiency. The apparatus is especially suitable retrofit to existing water intakes. The apparatus is modular to allow use plural modules in parallel to adjust for water flow conditions. The apparatus has a floor, two opposite side walls, and a roof which define a water flow passage and a plane screen within the passage. The screen is oriented to divert fish into a fish bypass which carries fish to a safe discharge location. The dimensions of the floor, walls, and roof are selected to define the dimensions of the passage and to permit selection of the screen angle. The floor is bi-level with a level upstream of the screen and a level beneath screen selected to provide a uniform flow distribution through the screen. The apparatus may include separation walls to provide a water flow channel between the apparatus and the water intake. Lead walls may be used to adjust water flow conditions into the apparatus. The apparatus features stoplog guides near its upstream and downstream ends to permit the water flow passage to be dewatered. 3 figs

  19. Geopotential coefficient determination and the gravimetric boundary value problem: A new approach

    Science.gov (United States)

    Sjoeberg, Lars E.

    1989-01-01

    New integral formulas to determine geopotential coefficients from terrestrial gravity and satellite altimetry data are given. The formulas are based on the integration of data over the non-spherical surface of the Earth. The effect of the topography to low degrees and orders of coefficients is estimated numerically. Formulas for the solution of the gravimetric boundary value problem are derived.

  20. Light shielding apparatus

    Science.gov (United States)

    Miller, Richard Dean; Thom, Robert Anthony

    2017-10-10

    A light shielding apparatus for blocking light from reaching an electronic device, the light shielding apparatus including left and right support assemblies, a cross member, and an opaque shroud. The support assemblies each include primary support structure, a mounting element for removably connecting the apparatus to the electronic device, and a support member depending from the primary support structure for retaining the apparatus in an upright orientation. The cross member couples the left and right support assemblies together and spaces them apart according to the size and shape of the electronic device. The shroud may be removably and adjustably connectable to the left and right support assemblies and configured to take a cylindrical dome shape so as to form a central space covered from above. The opaque shroud prevents light from entering the central space and contacting sensitive elements of the electronic device.

  1. Design of neutral particle incident heating apparatus for large scale helical apparatus

    Energy Technology Data Exchange (ETDEWEB)

    Kaneko, Osamu; Oka, Yoshihide; Osakabe, Masaki; Takeiri, Yasuhiko; Tsumori, Katsuyoshi; Akiyama, Ryuichi; Asano, Eiji; Kawamoto, Toshikazu; Kuroda, Tsutomu [National Inst. for Fusion Science, Nagoya (Japan)

    1997-02-01

    In the Institute of Nuclear Fusion Science, construction of the large scale helical apparatus has been progressed favorably, and constructions of the heating apparatus as well as of electron resonance apparatus were begun in their orders under predetermined manner since 1994 fiscal year. And, on 1995 fiscal year, construction of neutral particle incident heating apparatus, leading heat apparatus, was begun under 3 years planning. The plasma heating study system adopted the study results developed in this institute through the large scale hydrogen negative ion source and also adopted thereafter development on nuclear fusion study by modifying the original specification set at the beginning of the research plan before 7 years. As a result, system design was changed from initial 125 KeV to 180 KeV in the beam energy and to execute 15 MW incidence using two sets beam lines, to begin its manufacturing. Here is described on its new design with reason of its modifications. (G.K.)

  2. Gravimetric and volumetric approaches adapted for hydrogen sorption measurements with in situ conditioning on small sorbent samples

    International Nuclear Information System (INIS)

    Poirier, E.; Chahine, R.; Tessier, A.; Bose, T.K.

    2005-01-01

    We present high sensitivity (0 to 1 bar, 295 K) gravimetric and volumetric hydrogen sorption measurement systems adapted for in situ sample conditioning at high temperature and high vacuum. These systems are designed especially for experiments on sorbents available in small masses (mg) and requiring thorough degassing prior to sorption measurements. Uncertainty analysis from instrumental specifications and hydrogen absorption measurements on palladium are presented. The gravimetric and volumetric systems yield cross-checkable results within about 0.05 wt % on samples weighing from (3 to 25) mg. Hydrogen storage capacities of single-walled carbon nanotubes measured at 1 bar and 295 K with both systems are presented

  3. Gamma apparatuses for radiotherapy

    International Nuclear Information System (INIS)

    Sul'kin, A.G.

    1986-01-01

    Scientific and technical achievements in development and application of gamma therapeutic apparatuses for external and intracavity irradiations are generalized. Radiation-physical parameters of apparatuses providing usability of progressive methods in radiotherapy of onclogical patients are given. Optimization of main apparatus elements, ensurance of its operation reliability, reduction of errors of irradiation plan reproduction are considered. Attention is paid to radiation safety

  4. Determination of plutonium in pure plutonium nitrate solutions - Gravimetric method

    International Nuclear Information System (INIS)

    1987-01-01

    This International Standard specifies a precise and accurate gravimetric method for determining the concentration of plutonium in pure plutonium nitrate solutions and reference solutions, containing between 100 and 300 g of plutonium per litre, in a nitric acid medium. The weighed portion of the plutonium nitrate is treated with sulfuric acid and evaporated to dryness. The plutonium sulfate is decomposed and formed to oxide by heating in air. The oxide is ignited in air at 1200 to 1250 deg. C and weighed as stoichiometric plutonium dioxide, which is stable and non-hygroscopic

  5. Waste Water Treatment Apparatus and Methods

    Science.gov (United States)

    Littman, Howard (Inventor); Plawsky, Joel L. (Inventor); Paccione, John D. (Inventor)

    2014-01-01

    An improved draft tube spout fluid bed (DTSFB) mixing, handling, conveying, and treating apparatus and systems, and methods for operating are provided. The apparatus and systems can accept particulate material and pneumatically or hydraulically conveying the material to mix and/or treat the material. In addition to conveying apparatus, a collection and separation apparatus adapted to receive the conveyed particulate material is also provided. The collection apparatus may include an impaction plate against which the conveyed material is directed to improve mixing and/or treatment. The improved apparatus are characterized by means of controlling the operation of the pneumatic or hydraulic transfer to enhance the mixing and/or reacting by controlling the flow of fluids, for example, air, into and out of the apparatus. The disclosed apparatus may be used to mix particulate material, for example, mortar; react fluids with particulate material; coat particulate material, or simply convey particulate material.

  6. Construction of shallow land simulation apparatuses

    International Nuclear Information System (INIS)

    Yamamoto, Tadatoshi; Ohtsuka, Yoshiro; Takebe, Shinichi; Ohnuki, Toshihiko; Ogawa, Hiromichi; Harada, Yoshikane; Saitoh, Kazuaki; Wadachi, Yoshiki

    1984-07-01

    Shallow land simulation apparatuses in which natural soil can be used as testing soil have been constructed to investigate the migration characteristics of radionuclides in a disposal site. These apparatuses consist of aerated zone apparatus and aquifer zone one. In the aerated zone apparatus, aerated soil upon ground water level is contained in the soil column (d: 30cm x h: 120cm). In the aquifer zone apparatus, aquifer soil laying ground water level is contained in the soil vessel (b: 90cm x l: 270cm x h: 45cm). This report describes the outline of shallow land simulation apparatuses : function of apparatuses and specification of devices, analysis of obstructions, safety rules, analysis of accidents and operation manual. (author)

  7. Study of the corrosion behavior of magnesium alloy weldings in NaCl solutions by gravimetric tests

    Directory of Open Access Journals (Sweden)

    Segarra, José A.

    2015-09-01

    Full Text Available In this article, the corrosion behavior of commercial AZ31 welded plates in aqueous chloride media was investigated by means of gravimetric techniques and Neutral Salt Spray tests (NSS. The AZ31 samples tested were welded using Gas Tugsten Arc Welding (GTAW and different filler materials. Material microstructures were investigated by optical microscopy to stablish the influence of those microstructures in the corrosion behavior. Gravimetric and NSS tests indicate that the use of more noble filler alloys for the sample welding, preventing the reduction of aluminum content in weld beads, does not imply a better corrosion behavior.En este artículo se ha investigado el comportamiento frente a la corrosión en medios acuosos salinos de chapas soldadas de aleación AZ31 mediante técnicas gravimétricas y ensayo en cámara de niebla salina. Las muestras estudiadas han sido soldadas mediante soldadura TIG (Tungsten Inert Gas y con diferentes materiales de aporte. En el estudio se ha empleado microscopía óptica para analizar la microestructura. Los ensayos de gravimetría y los ensayos de niebla salina indican que el empleo de materiales de aporte más nobles para soldar las muestras evitando la disminución del contenido en aluminio en los cordones, no implica un mejor comportamiento frente a la corrosión.

  8. Large Rotor Test Apparatus

    Data.gov (United States)

    Federal Laboratory Consortium — This test apparatus, when combined with the National Full-Scale Aerodynamics Complex, produces a thorough, full-scale test capability. The Large Rotor Test Apparatus...

  9. Conduit grinding apparatus

    Science.gov (United States)

    Nachbar, Henry D.; Korytkowski, Alfred S.

    1991-01-01

    A grinding apparatus for grinding the interior portion of a valve stem receiving area of a valve. The apparatus comprises a faceplate, a plurality of cams mounted to an interior face of the faceplate, a locking bolt to lock the faceplate at a predetermined position on the valve, a movable grinder and a guide tube for positioning an optical viewer proximate the area to be grinded. The apparatus can either be rotated about the valve for grinding an area of the inner diameter of a valve stem receiving area or locked at a predetermined position to grind a specific point in the receiving area.

  10. Modified method for zirconium or hafnium gravimetric determination with glycolic acid derivatives

    International Nuclear Information System (INIS)

    Barbieri, R.S.; Rocha, J.C.; Terra, V.R.; Marques Neto, A.

    1989-01-01

    The conditions for gravimetric determination of zirconium or hafnium by glicolic acid derivatives were studied by thermogravimetric analysis. The method utilized shown that after precipitation, washing and drying of precipitates at 150 0 C, the resulting solid was weighed in the form of [M{RCH(OH)COO} 4 ] (M = Zr,Hf;R = C 6 H 5 , β-C 10 H 7 ,p-BrC 6 H 4 ). (author) [pt

  11. Comparison Of Metal Corrosion Inhibition By Gravimetric And Linear Polarization Resistance Methods

    OpenAIRE

    Banerji, Shankha

    1992-01-01

    Studies were conducted to evaluate the effectiveness of various dosages of the selected silicate and phosphate compounds applied for corrosion inhibition of cast iron, copper, lead, and galvanized steel specimens. The compounds selected for study were zinc polyphosphate (Calgon C-39), zinc orthophosphate (Virchem V-931), sodium metasilicate and glassy silicate. The effectiveness of these compounds for corrosion inhibition were studied under differing water quality conditions using gravimetric...

  12. Pipework inspection apparatus

    International Nuclear Information System (INIS)

    Wrigglesworth, K.J.; Knowles, J.F.

    1987-01-01

    The patent concerns a pipework inspection apparatus, which is capable of negotiating bends in pipework. The apparatus comprises a TV camera system, which contains an optical section and an electronics section, which are connected by a flexible coupling. The system can be pulled or pushed along the bore of the pipework. (U.K.)

  13. Photometrically measured continuous personal PM(2.5) exposure: levels and correlation to a gravimetric method.

    Science.gov (United States)

    Lanki, Timo; Alm, Sari; Ruuskanen, Juhani; Janssen, Nicole A H; Jantunen, Matti; Pekkanen, Juha

    2002-05-01

    There is evidence that hourly variations in exposure to airborne particulate matter (PM) may be associated with adverse health effects. Still there are only few published data on short-term levels of personal exposure to PM in community settings. The objectives of the study were to assess hourly and shorter-term variations in personal PM(2.5) exposure in Helsinki, Finland, and to compare results from portable photometers to simultaneously measured gravimetric concentrations. The effect of relative humidity on the photometric results was also evaluated. Personal PM(2.5) exposures of elderly persons were assessed for 24 h every second week, resulting in 308 successful measurements from 47 different subjects. Large changes in concentrations in minutes after cooking or changing microenvironment were seen. The median of daily 1-h maxima was over twice the median of 24-h averages. There was a strong significant association between the two means, which was not linear. Median (95th percentile) of the photometric 24-h concentrations was 12.1 (37.7) and of the 24-h gravimetric concentrations 9.2 (21.3) microg/m3. The correlation between the photometric and the gravimetric method was quite good (R2=0.86). Participants spent 94.1% of their time indoors or in a vehicle, where relative humidity is usually low and thus not likely to cause significant effects on photometric results. Even outdoors, the relative humidity had only modest effect on concentrations. Photometers are a promising method to explore the health effects of short-term variation in personal PM(2.5) exposure.

  14. A new and simple gravimetric method for determination of uranium

    International Nuclear Information System (INIS)

    Saxena, A.K.

    1994-01-01

    A new and simple gravimetric method for determining uranium has been described. Using a known quantity of uranyl nitrate as the test solution, an alcoholic solution of 2-amino-2-methyl 1:3 propanediol (AMP) was added slowly. A yellow precipitate was obtained which was filtered through ashless filter paper, washed with alcohol, dried and ignited at 800 degC for 4h. It gave a black powder as a product which was shown by X-ray diffraction to be U 3 O 8 . The percentage error was found in the range -0.09 to +0.89. (author). 8 refs., 1 tab

  15. Gravimetric determination of hafnium through its arsenate in carbide and boride of hafnium

    International Nuclear Information System (INIS)

    Rasulbekova, R.A.; Mamedov, I.A.

    1976-01-01

    A gravimetric method of determining hafnium through hydroarsenate has been recommended. The method differs from the known ones by its simplicity and by the recalculation coefficient which is more than by 50% smaller than that used in preparing a weight form of HfO 2 . Upon development of gravimetric determination of hafnium through hydro-and pyroarsenate, an investigation has been conducted with the aim to find some physico-chemical constants of hafnium hydroarsenate. The weighed amount of hafnium hydroarsenate is dissolved in sulphuric acid (2:5). The precipitate of hafnium hydroarsenate has been studied for recording infrared absorption spectra. Thermographic analysis of the precipitate has been performed. Thermogram reveals endothermal effect at 105 deg C and exothermal at 840 deg C. Water solubility of hafnium has been determined equal to 1.75x10 6 g mol/l. The corresponding solubility product of the precipitate has been calculated which is 2.1x10 -17 . It is shown that the method possesses certain selectivity, sufficient accuracy, and is rather fast. It has been established that determination can be performed in the presence of excess amounts of ions

  16. Tectonic evolution of the Paranoá basin: New evidence from gravimetric and stratigraphic data

    Science.gov (United States)

    Martins-Ferreira, Marco Antonio Caçador; Campos, José Eloi Guimarães; Von Huelsen, Monica Giannoccaro

    2018-06-01

    Field gravimetric and stratigraphic surveys were conducted with the aim to constraint the mechanisms responsible for the initiation of the Stenian-Tonian Paranoá basin, central Brazil, a subject not yet studied in detail. The Paranoá Group crops out in the external zone of the Brasília Belt, a Neoproterozoic orogen in the western margin of the São Francisco Craton. Detailed geological mapping confirmed the existence of a regional scale fault that controlled sedimentation of the Paranoá Group during the deposition of its basal formations, revealing important details about basin initiation and early evolution. Gravimetric modeling indicates the existence of paleorift structures beneath the Paranoá sequence in the study area. Results from both stratigraphic and gravimetric surveys show strong evidence of mechanical subsidence by faulting during basin initiation. Unsorted, angular, clasts cut by quartz veins and brecciated boulders present in the basal conglomerate, support this hypothesis. Basin initiation faults coincide with deeper paleorift faults and are thus interpreted as reactivations of the older Statherian Araí Rift. The reactivations favored an initial regime of mechanical subsidence, dominated by the development of epirogenic arches subsiding at different rates. Apart from faulting activity, the post-basal sequence presents no evidence of rift environment in the strict sense. Besides, the great lateral continuity and relatively constant thickness of facies, indicate that an initial mechanic subsidence rapidly gave way to flexural subsidence during subsequent stages of basin evolution. The Paranoá Group do not present reliable characteristics that would allow its strict classification as a passive margin. Its main stratigraphic characteristics, tectonic location and basement architecture, indicate that the Paranoá Group was deposited in a cratonic margin basin, and may have been either connected to a passive margin basin at times of sea level rise

  17. A cost-effective technique for integrating personal radiation dose assessment with personal gravimetric sampling

    International Nuclear Information System (INIS)

    Strydom, R.; Rolle, R.; Van der Linde, A.

    1992-01-01

    During recent years there has been an increasing awareness internationally of radiation levels in the mining and milling of radioactive ores, including those from non-uranium mines. A major aspect of radiation control is concerned with the measurement of radiation levels and the assessment of radiation doses incurred by individual workers. Current techniques available internationally for personnel monitoring of radiation exposures are expensive and there is a particular need to reduce the cost of personal radiation monitoring in South African gold mines because of the large labour force employed. In this regard the obvious benefits of integrating personal radiation monitoring with existing personal monitoring systems already in place in South African gold mines should be exploited. A system which can be utilized for this purpose is personal gravimetric sampling. A new cost-effective technique for personal radiation monitoring, which can be fully integrated with the personal gravimetric sampling strategy being implemented on mines, has been developed in South Africa. The basic principles of this technique and its potential in South African mines are described. 9 refs., 7 figs

  18. Near infrared spectrometry for faecal fat measurement: comparison with conventional gravimetric and titrimetric methods.

    Science.gov (United States)

    Benini, L; Caliari, S; Guidi, G C; Vaona, B; Talamini, G; Vantini, I; Scuro, L A

    1989-01-01

    This investigation was aimed at comparing a new method for measuring faecal fat excretion, carried out with a semi-automated instrument by using near infrared analysis (NIRA), with the traditional titrimetric (Van de Kamer) and gravimetric (Sobel) methods. Near infrared analysis faecal fat was assayed on the three day stool collection from 118 patients (68 chronic pancreatitis, 19 organic diseases of the gastrointestinal tract, 19 alcoholic liver disease, 12 functional gastrointestinal disorders). A strict linear correlation was found between NIRA and both the titrimetric (r = 0.928, p less than 0.0001) and the gravimetric (r = 0.971, p less than 0.0001) methods. On homogenised faeces, a mean coefficient of variation of 2.1 (SD 1.71)% was found. Before homogenisation (where a mean coefficient of variation of 7% was found) accurate results were obtained when the mean of five measurements was considered. In conclusion, the assay of faecal fat excretion by the near infrared reflessometry appears a simple, rapid and reliable method for measuring steatorrhoea. PMID:2583563

  19. Determination of uranium in coated fuel particle compact by potassium fluoride fusion-gravimetric method

    International Nuclear Information System (INIS)

    Ito, Mitsuo; Iso, Shuichi; Hoshino, Akira; Suzuki, Shuichi.

    1992-03-01

    Potassium fluoride-gravimetric method has been developed for the determination of uranium in TRISO type-coated fuel particle compact. Graphite matrix in the fuel compact is burned off by heating it in a platinum crucible at 850degC. The coated fuel particles thus obtained are decomposed by fusion with potassium fluoride at 900degC. The melt was dissolved with sulfuric acid. Uranium is precipitated as ammonium diuranate, by passing ammonia gas through the solution. The resulting precipitate is heated in a muffle furnace at 850degC, to convert uranium into triuranium octoxide. Uranium in the triuranium octoxide was determined gravimetrically. Ten grams of caoted fuel particles were completely decomposed by fusion with 50 g of potassium fluoride at 900degC for 3 hrs. Analytical result for uranium in the fuel compact by the proposed method was 21.04 ± 0.05 g (n = 3), and was in good agreement with that obtained by non-destructive γ-ray measurement method : 21.01 ± 0.07 g (n = 3). (author)

  20. The Comparison Of Silicon Analysis For The Uranium Silicide Fuel Using Spectrophotometrical And Gravimetrical Methods

    International Nuclear Information System (INIS)

    Putro, P. K.; Suripto, A.; Putra, S.; Gunanjar

    1996-01-01

    The analysis of silicon content in the uranium silicide fuel spectro-photometrical and gravimetrical method have been performed. The nitrous oxide-acetylene was used in the atomic absorption spectrophotometry (AAS) on the wave length of 251.6 nm, and the mixture of ammonium hepta molybdate complexes and SnC1 2 as reductor were applied during analysis by UV-VIS spectrophotometry (UV-VIS) on the wave length of 757.5 mm. The reagent of HCLO 4 and HNO 3 were used for determining Si content by gravimetrical methods. The results of this comparison is as follows: the accuracy result is around 96.37 % + 0.24 % for the Si concentration up to 300 ppm (the AAS), is 138.60 % = 0.43 % for the Si concentration range between 0.1-1.5 ppm (UV-VIS), and is 51.13 % + 0.8 % for 1 gram of Si (gravimetry). The results also show that the lowest analytical error is obtained by AAS method

  1. Radioimmunoassay apparatus

    International Nuclear Information System (INIS)

    1981-01-01

    Apparatus for performing a quantitative radioimmunoassay comprising: a substantially spherical bead for carrying an antibody and a gripper for gripping said bead, said gripper comprising an integrally formed unit having a single elongate handle portion and a plurality of resilient fingers arranged at the base of the handle so that when said bead is secured within said fingers, said bead may be freely rotated about any diametric axis of the bead. In particular the invention relates to an apparatus for a two site immunoradiometric assay for serum ferritin in human blood samples. (author)

  2. TRANSFORMER APPARATUS

    Science.gov (United States)

    Wolfgang, F.; Nicol, J.

    1962-11-01

    Transformer apparatus is designed for measuring the amount of a paramagnetic substance dissolved or suspended in a diamagnetic liquid. The apparatus consists of a cluster of tubes, some of which are closed and have sealed within the diamagnetic substance without any of the paramagnetic material. The remaining tubes are open to flow of the mix- ture. Primary and secondary conductors are wrapped around the tubes in such a way as to cancel noise components and also to produce a differential signal on the secondaries based upon variations of the content of the paramagnetic material. (AEC)

  3. Radiotherapy apparatus

    International Nuclear Information System (INIS)

    Leung, P.M.; Webb, H.P.J.

    1985-01-01

    This invention relates to apparatus for applying intracavitary radiotherapy. In previously-known systems radioactive material is conveyed to a desired location within a patient by transporting a chain of balls pneumatically to and from an appropriately inserted applicator. According to this invention a ball chain for such a purpose comprises several radioactive balls separated by non-radioactive tracer balls of radiographically transparent material of lower density and surface hardness than the radioactive balls. The invention also extends to radiotherapy treatment apparatus comprising a storage, sorting and assembly system

  4. A problem in gravimetric method for the determination of rare earth elements as oxide after the fluoride separation

    International Nuclear Information System (INIS)

    Takada, Kunio

    1979-01-01

    For the gravimetric determination of lanthanum, it was precipitated as fluoride and converted to oxide by igniting (ca. 930 0 C) in a town gas flame. However, the oxidation of lanthanum fluoride by ignition was incomplete, the major part of the precipitate being converted to oxyfluoride (LaOF) and a mixture of oxide and oxyfluoride resulted. Therefore, analytical results were generally (5 -- 7)% higher than theoretically expected. The lanthanum fluoride became converted into the oxide by repeating ignition (ca. 1070 0 C) three times, each for (30 -- 40)min. However, the weight was lower than that of the corresponding sesquioxide, La 2 O 3 . Except for ytterbium and lutetium, gravimetric results as oxides for the other rare earth elements (Y, Pr, Nd, Sm, Eu and Gd) were higher than theoretical values. Therefore, the precipitation of the rare earth elements as fluoride and the subsequent determination as oxide by ignition of the fluoride could not be recommended as the gravimetric method for the rare earths. In order to obtain accurate results for major to minor amounts of the rare earth elements, an EDTA titration at pH 6 should be used after the dissolution of fluoride in acid, if the fluoride precipitation separation is involved. (author)

  5. The use of cerium(IV) phosphate for the gravimetric determination and separation of cerium

    International Nuclear Information System (INIS)

    Masin, V.; Dolezal, J.

    1978-01-01

    A method for the gravimetric determination of cerium as Ce 3 (PO 4 ) 4 is described. Cerium can be separated from many metals in this form, as well as from permanganate and dichromate; the cerium separated can then be titrated with iron(II) solution. The method was verified for the determination of cerium in a rare earth concentrate. (Auth.)

  6. Design and realization of the high-precision weighing systems as the gravimetric references in PTB's national water flow standard

    International Nuclear Information System (INIS)

    Engel, Rainer; Beyer, Karlheinz; Baade, Hans-Joachim

    2012-01-01

    PTB's ‘Hydrodynamic Test Field’, which represents a high-accuracy water flow calibration facility, serves as the national primary standard for liquid flow measurands. As the core reference device of this flow facility, a gravimetric standard has been incorporated, which comprises three special-design weighing systems: 300 kg, 3 tons and 30 tons. These gravimetric references were realized as a combination of a strain-gauge-based and an electromagnetic-force-compensation load-cell-based balance, each. Special emphasis had to be placed upon the dynamics design of the whole weighing system, due to the high measurement resolution and the dynamic behavior of the weighing systems, which are dynamically affected by mechanical vibrations caused by environmental impacts, flow machinery operation, flow noise in the pipework and induced wave motions in the weigh tanks. Taking into account all the above boundary conditions, the design work for the gravimetric reference resulted in a concrete foundation ‘rock’ of some 300 tons that rests on a number of vibration isolators. In addition to these passively operating vibration isolators, the vibration damping effect is enhanced by applying an electronic level regulation device. (paper)

  7. Apparatus for Teaching Physics.

    Science.gov (United States)

    Gottlieb, Herbert H., Ed.

    1981-01-01

    Describes: (1) a variable inductor suitable for an inductance-capacitance bridge consisting of a fixed cylindrical solenoid and a moveable solenoid; (2) long-range apparatus for demonstrating falling bodies; and (3) an apparatus using two lasers to demonstrate ray optics. (SK)

  8. Time-Resolved Gravimetric Method To Assess Degassing of Roasted Coffee.

    Science.gov (United States)

    Smrke, Samo; Wellinger, Marco; Suzuki, Tomonori; Balsiger, Franz; Opitz, Sebastian E W; Yeretzian, Chahan

    2018-05-30

    During the roasting of coffee, thermally driven chemical reactions lead to the formation of gases, of which a large fraction is carbon dioxide (CO 2 ). Part of these gases is released during roasting while part is retained inside the porous structure of the roasted beans and is steadily released during storage or more abruptly during grinding and extraction. The release of CO 2 during the various phases from roasting to consumption is linked to many important properties and characteristics of coffee. It is an indicator for freshness, plays an important role in shelf life and in packaging, impacts the extraction process, is involved in crema formation, and may affect the sensory profile in the cup. Indeed, and in view of the multiple roles it plays, CO 2 is a much underappreciated and little examined molecule in coffee. Here, we introduce an accurate, quantitative, and time-resolved method to measure the release kinetics of gases from whole beans and ground coffee using a gravimetric approach. Samples were placed in a container with a fitted capillary to allow gases to escape. The time-resolved release of gases was measured via the weight loss of the container filled with coffee. Long-term stability was achieved using a customized design of a semimicro balance, including periodic and automatic zero value measurements and calibration procedures. The novel gravimetric methodology was applied to a range of coffee samples: (i) whole Arabica beans and (ii) ground Arabica and Robusta, roasted to different roast degrees and at different speeds (roast air temperatures). Modeling the degassing rates allowed structural and mechanistic interpretation of the degassing process.

  9. Radiation imaging apparatus

    International Nuclear Information System (INIS)

    1979-01-01

    This invention relates to a radiation imaging apparatus. It relates more particularly to apparatus of this general type which employs stationary X-ray source and detector arrays capable of acquiring multiple ultrafast scans per second to facilitate the dynamic study of moving human organs such as the beating heart. While the invention has many applications, it has particular utility in connection with computerized tomographic (CT) scanners. (Auth.)

  10. Density Imaging of Puy de Dôme Volcano by Joint Inversion of Muographic and Gravimetric Data

    Science.gov (United States)

    Barnoud, A.; Niess, V.; Le Ménédeu, E.; Cayol, V.; Carloganu, C.

    2016-12-01

    We aim at jointly inverting high density muographic and gravimetric data to robustly infer the density structure of volcanoes. We use the puy de Dôme volcano in France as a proof of principle since high quality data sets are available for both muography and gravimetry. Gravimetric inversion and muography are independent methods that provide an estimation of density distributions. On the one hand, gravimetry allows to reconstruct 3D density variations by inversion. This process is well known to be ill-posed and intrinsically non unique, thus it requires additional constraints (eg. a priori density model). On the other hand, muography provides a direct measurement of 2D mean densities (radiographic images) from the detection of high energy atmospheric muons crossing the volcanic edifice. 3D density distributions can be computed from several radiographic images, but the number of images is generally limited by field constraints and by the limited number of available telescopes. Thus, muon tomography is also ill-posed in practice.In the case of the puy de Dôme volcano, the density structures inferred from gravimetric data (Portal et al. 2016) and from muographic data (Le Ménédeu et al. 2016) show a qualitative agreement but cannot be compared quantitatively. Because each method has different intrinsic resolutions due to the physics (Jourde et al., 2015), the joint inversion is expected to improve the robustness of the inversion. Such joint inversion has already been applied in a volcanic context (Nishiyama et al., 2013).Volcano muography requires state-of-art, high-resolution and large-scale muon detectors (Ambrosino et al., 2015). Instrumental uncertainties and systematic errors may constitute an important limitation for muography and should not be overlooked. For instance, low-energy muons are detected together with ballistic high-energy muons, decreasing the measured value of the mean density closed to the topography.Here, we jointly invert the gravimetric and

  11. Determination of uranium by a gravimetric-volumetric titration method

    International Nuclear Information System (INIS)

    Krtil, J.

    1998-01-01

    A volumetric-gravimetric modification of a method for the determination of uranium based on the reduction of uranium to U (IV) in a phosphoric acid medium and titration with a standard potassium dichromate solution is described. More than 99% of the stoichiometric amount of the titrating solution is weighed and the remainder is added volumetrically by using the Mettler DL 40 RC Memotitrator. Computer interconnected with analytical balances collects continually the data on the analyzed samples and evaluates the results of determination. The method allows to determine uranium in samples of uranium metal, alloys, oxides, and ammonium diuranate by using aliquot portions containing 30 - 100 mg of uranium with the error of determination, expressed as the relative standard deviation, of 0.02 - 0.05%. (author)

  12. Nuclear fuel technology - Determination of uranium in uranyl nitrate solutions of nuclear grade quality - Gravimetric method

    International Nuclear Information System (INIS)

    2003-01-01

    This International Standard specifies a precise and accurate gravimetric method for determining the mass fraction of uranium in uranyl nitrate solutions of nuclear grade quality containing more than 100 g/kg of uranium. Non-volatile impurities influence the accuracy of the method

  13. Comparison of gravimetric and spectrophotometric methods for the determination of O/U ratios in uranium oxides

    International Nuclear Information System (INIS)

    Esteban, Adolfo; Eppis, Maria Rosa

    2004-01-01

    One important parameter to specify in nuclear fuels is the oxygen-metal ratio; many tests were described in literature to determine it. Possibly, gravimetric methods are the most used and usually a good precision was obtained analysing sintered materials. However, the humidity sorbed in the samples and impurities affect these methods, especially in powders. On the other hand, the spectrophotometric methods determine oxygen-uranium ratio by measuring the absorbances of different ionic species in phosphoric acid. This technique is simply and is not affected by humidity and impurities. Owing to discrepancy in the results between both methods, it was carried out in our laboratory, a study on various gravimetric and spectrophotometric methods. Several assays and analysis were performed comparing test procedures, trying to obtain better precision and accuracy. This work presents the results obtained and the recommend procedure to use with sintered and unsintered materials

  14. Gravimetric Analysis of Bismuth in Bismuth Subsalicylate Tablets: A Versatile Quantitative Experiment for Undergraduate Laboratories

    Science.gov (United States)

    Davis, Eric; Cheung, Ken; Pauls, Steve; Dick, Jonathan; Roth, Elijah; Zalewski, Nicole; Veldhuizen, Christopher; Coeler, Joel

    2015-01-01

    In this laboratory experiment, lower- and upper-division students dissolved bismuth subsalicylate tablets in acid and precipitated the resultant Bi[superscript 3+] in solution with sodium phosphate for a gravimetric determination of bismuth subsalicylate in the tablets. With a labeled concentration of 262 mg/tablet, the combined data from three…

  15. Sludge recovery apparatus

    International Nuclear Information System (INIS)

    Marmo, A.R.

    1979-01-01

    An improved design of a sludge recovery apparatus used in the fabrication of nuclear fuel is described. This apparatus provides for automatic separation of sludge from the grinder coolant, drying of the sludge into a flowable powder and transfer of the dry powder to a salvage container. It can be constructed to comply with criticality-safe-geometry requirements and to obviate need for operating personnel in its immediate vicinity. (UK)

  16. Informationization nuclear apparatus communication technique

    International Nuclear Information System (INIS)

    Yu Tiqi; Fang Zongliang; Wen Qilin

    2006-01-01

    The paper explains the request of communication ability in nuclear technique application area. Based on the actuality of nuclear apparatus communication ability, and mainly combining with the development of communication technique, the authors analyzes the application trend of communication technique applying in nuclear apparatus, for the apparatus and system needing communication ability, they need selecting suitable communication means to make them accomplish the task immediately and effectively. (authors)

  17. Comparison of Glaciological and Gravimetric Glacier Mass Balance Measurements of Taku and Lemon Creek Glaciers, Southeast Alaska

    Science.gov (United States)

    Vogler, K.; McNeil, C.; Bond, M.; Getraer, B.; Huxley-Reicher, B.; McNamara, G.; Reinhardt-Ertman, T.; Silverwood, J.; Kienholz, C.; Beedle, M. J.

    2017-12-01

    Glacier-wide annual mass balances (Ba) have been calculated for Taku (726 km2) and Lemon Creek glaciers (10.2 km2) since 1946 and 1953 respectively. These are the longest mass balance records in North America, and the only Ba time-series available for Southeast Alaska, making them particularly valuable for the global glacier mass balance monitoring network. We compared Ba time-series from Taku and Lemon Creek glaciers to Gravity Recovery and Climate Experiment (GRACE) mascon solutions (1352 and 1353) during the 2004-2015 period to assess how well these gravimetric solutions reflect individual glaciological records. Lemon Creek Glacier is a challenging candidate for this comparison because it is small compared to the 12,100 km2 GRACE mascon solutions. Taku Glacier is equally challenging because its mass balance is stable compared to the negative balances dominating its neighboring glaciers. Challenges notwithstanding, a high correlation between the glaciological and gravimetrically-derived Ba for Taku and Lemon Creek glaciers encourage future use of GRACE to measure glacier mass balance. Additionally, we employed high frequency ground penetrating radar (GPR) to measure the variability of accumulation around glaciological sites to assess uncertainty in our glaciological measurements, and the resulting impact to Ba. Finally, we synthesize this comparison of glaciological and gravimetric mass balance solutions with a discussion of potential sources of error in both methods and their combined utility for measuring regional glacier change during the 21st century.

  18. Apparatuses And Systems For Embedded Thermoelectric Generators

    KAUST Repository

    Hussain, Muhammad M.; Inayat, Salman Bin; Smith, Casey Eben

    2013-01-01

    An apparatus and a system for embedded thermoelectric generators are disclosed. In one embodiment, the apparatus is embedded in an interface where the ambient temperatures on two sides of the interface are different. In one embodiment, the apparatus is fabricated with the interface in integrity as a unitary piece. In one embodiment, the apparatus includes a first thermoelectric material embedded through the interface. The apparatus further includes a second thermoelectric material embedded through the interface. The first thermoelectric material is electrically coupled to the second thermoelectric material. In one embodiment, the apparatus further includes an output structure coupled to the first thermoelectric material and the second thermoelectric material and configured to output a voltage.

  19. Apparatuses And Systems For Embedded Thermoelectric Generators

    KAUST Repository

    Hussain, Muhammad M.

    2013-08-08

    An apparatus and a system for embedded thermoelectric generators are disclosed. In one embodiment, the apparatus is embedded in an interface where the ambient temperatures on two sides of the interface are different. In one embodiment, the apparatus is fabricated with the interface in integrity as a unitary piece. In one embodiment, the apparatus includes a first thermoelectric material embedded through the interface. The apparatus further includes a second thermoelectric material embedded through the interface. The first thermoelectric material is electrically coupled to the second thermoelectric material. In one embodiment, the apparatus further includes an output structure coupled to the first thermoelectric material and the second thermoelectric material and configured to output a voltage.

  20. CASTING METHOD AND APPARATUS

    Science.gov (United States)

    Gray, C.F.; Thompson, R.H.

    1958-10-01

    An improved apparatus for the melting and casting of uranium is described. A vacuum chamber is positioned over the casting mold and connected thereto, and a rod to pierce the oxide skin of the molten uranium is fitted into the bottom of the melting chamber. The entire apparatus is surrounded by a jacket, and operations are conducted under a vacuum. The improvement in this apparatus lies in the fact that the top of the melting chamber is fitted with a plunger which allows squeezing of the oxide skin to force out any molten uranium remaining after the skin has been broken and the molten charge has been cast.

  1. Gravimetric model of the Gastre trough, province of Chubut, Argentina; Modelo gravimetrico en la fosa de Gastre, provincia de Chubut, Argentina

    Energy Technology Data Exchange (ETDEWEB)

    Lince Klinger, F.; Nacif, S.; Martinez, M. P.; Gimenez, M. E.; Ruiz, F.; Alvarez, O.

    2011-07-01

    A gravimetric study of the Gastre trough in the Province of Chubut, to the southwest of the Canadon Asfalto basin, has allowed us to determine the geometry of its crystalline basement. Using filtering techniques we were able to map residual Bouguer anomalies, which show the heterogeneities situated within the upper crust, some of which are linked to recognised geological structures. The gravimetric minima in the residual Bouguer anomaly map are associated with graben-type basins, flanked by positive gravity values associated with alignments identified on the surface and with the overall topographic relief of the Gastre trough. After suitable treatment of the density values of the outcrops and seismic data we were able to construct a 2D density model, perpendicular to the trough, which indicated a depth of 3600 m. The importance of this study lies in the fact that it has been possible to arrive at a gravimetric characterization of the Gastre trough in the Canadon Asfalto basin sector, a potentially hydrocarbon-bearing area hitherto lacking in reliable data concerning its subsoil. (Author)

  2. Gravimetric and conductometric studies of the sedimentation kinetics in aqueous dispersions of kaoline

    International Nuclear Information System (INIS)

    Bulavyin, L.A.; Khrapatij, S.V.; Koval'chuk, V.Yi.; Klepko, V.V.; Lebovka, M.Yi.

    2006-01-01

    Using gravimetric and conductometric methods, the sedimentation kinetics in aqueous suspensions of Alekseev kaoline has been studied for pH value range from 4 to 10. It has been found that pH increasing leads to the decreasing of mean radii of flocks linearly. We found that sedimentation kinetics for intermediate pH values can be described by scaling equations that crossover time defined transition from a gravitational mechanism of deposition to the diffusion one

  3. Gravimetric water distribution assessment from geoelectrical methods (ERT and EMI) in municipal solid waste landfill.

    Science.gov (United States)

    Dumont, Gaël; Pilawski, Tamara; Dzaomuho-Lenieregue, Phidias; Hiligsmann, Serge; Delvigne, Frank; Thonart, Philippe; Robert, Tanguy; Nguyen, Frédéric; Hermans, Thomas

    2016-09-01

    The gravimetric water content of the waste material is a key parameter in waste biodegradation. Previous studies suggest a correlation between changes in water content and modification of electrical resistivity. This study, based on field work in Mont-Saint-Guibert landfill (Belgium), aimed, on one hand, at characterizing the relationship between gravimetric water content and electrical resistivity and on the other hand, at assessing geoelectrical methods as tools to characterize the gravimetric water distribution in a landfill. Using excavated waste samples obtained after drilling, we investigated the influences of the temperature, the liquid phase conductivity, the compaction and the water content on the electrical resistivity. Our results demonstrate that Archie's law and Campbell's law accurately describe these relationships in municipal solid waste (MSW). Next, we conducted a geophysical survey in situ using two techniques: borehole electromagnetics (EM) and electrical resistivity tomography (ERT). First, in order to validate the use of EM, EM values obtained in situ were compared to electrical resistivity of excavated waste samples from corresponding depths. The petrophysical laws were used to account for the change of environmental parameters (temperature and compaction). A rather good correlation was obtained between direct measurement on waste samples and borehole electromagnetic data. Second, ERT and EM were used to acquire a spatial distribution of the electrical resistivity. Then, using the petrophysical laws, this information was used to estimate the water content distribution. In summary, our results demonstrate that geoelectrical methods represent a pertinent approach to characterize spatial distribution of water content in municipal landfills when properly interpreted using ground truth data. These methods might therefore prove to be valuable tools in waste biodegradation optimization projects. Copyright © 2016 Elsevier Ltd. All rights reserved.

  4. Gravimetric Measurements of Filtering Facepiece Respirators Challenged With Diesel Exhaust.

    Science.gov (United States)

    Satish, Swathi; Swanson, Jacob J; Xiao, Kai; Viner, Andrew S; Kittelson, David B; Pui, David Y H

    2017-07-01

    Elevated concentrations of diesel exhaust have been linked to adverse health effects. Filtering facepiece respirators (FFRs) are widely used as a form of respiratory protection against diesel particulate matter (DPM) in occupational settings. Previous results (Penconek A, Drążyk P, Moskal A. (2013) Penetration of diesel exhaust particles through commercially available dust half masks. Ann Occup Hyg; 57: 360-73.) have suggested that common FFRs are less efficient than would be expected for this purpose based on their certification approvals. The objective of this study was to measure the penetration of DPM through NIOSH-certified R95 and P95 electret respirators to verify this result. Gravimetric-based penetration measurements conducted using polytetrafluoroethylene (PTFE) and polypropylene (PP) filters were compared with penetration measurements made with a Scanning Mobility Particle Sizer (SMPS, TSI Inc.), which measures the particle size distribution. Gravimetric measurements using PP filters were variable compared to SMPS measurements and biased high due to adsorption of gas phase organic material. Relatively inert PTFE filters adsorbed less gas phase organic material resulting in measurements that were more accurate. To attempt to correct for artifacts associated with adsorption of gas phase organic material, primary and secondary filters were used in series upstream and downstream of the FFR. Correcting for adsorption by subtracting the secondary mass from the primary mass improved the result for both PTFE and PP filters but this correction is subject to 'equilibrium' conditions that depend on sampling time and the concentration of particles and gas phase hydrocarbons. Overall, the results demonstrate that the use of filters to determine filtration efficiency of FFRs challenged with diesel exhaust produces erroneous results due to the presence of gas phase hydrocarbons in diesel exhaust and the tendency of filters to adsorb organic material. Published by

  5. Investigations on vertical crustal movements in the Venezuelan Andes by gravimetric methods

    Science.gov (United States)

    Drewes, H.

    1978-01-01

    A precise gravimetric network has been installed in the Venezuelan Andes to study eventual gravity changes due to vertical tectonic movements. The design and the measurements of the network are described and the accuracy is estimated. In the center of the region a local gravity network has been reobserved three times. The detected variations are discussed. In order to obtain a genuine statement as far as possible about the significance of observed gravity changes, requirements for the procedure of monitoring precise gravity networks are pointed out.

  6. Self-propelled pulse X-ray apparatus Sirena-1

    International Nuclear Information System (INIS)

    Danil'chenko, N.T.; Ershov, L.S.; Il'chenko, A.V.; Krasil'nikov, S.B.; Kristalinskij, A.L.; Lozovoj, L.N.; Markov, S.N.; Morgovskij, L.Ya.

    1984-01-01

    The structure and specifications of a self-propelled pulse X-ray apparatus ''Sirena-1'' for testing oilt and gas pipelines welded joints are described. The apparatus is designed on the base of pulse X-ray apparatus MIRA. Apparatus control is realized by means of the 137 Cs source or manual control desk. The apparatus ensures perfect control sensitivity

  7. Encephalographic apparatus

    International Nuclear Information System (INIS)

    1981-01-01

    An X-ray apparatus is described for determining the size and location of brain tumours by tomography during pneumoencephalography. The apparatus comprises an image recording device arranged opposite an X-ray source and a frame mounted on a tiltable patient table and rotatable with respect to the table. A patient support is arranged in the frame and is rotatable with respect to the frame. Air injected into the patients' spinal column travels up into the brain and displaces some of the cerebral fluid. Tomographic X-ray exposures are made of the air bubble which moves around in the brain cavities as the patient is rotated. (U.K.)

  8. Radiography apparatus

    International Nuclear Information System (INIS)

    Sashin, D.; Sternglass, E.J.

    1982-01-01

    The apparatus of the present invention provides radiography apparatus wherein the use of a flat, generally rectangular beam or a fan-shaped beam of radiation in combination with a collimator, scintillator and device for optically coupling a self-scanning array of photodiodes to the scintillator means will permit production of images or image data with high contrast sensitivity and detail. It is contemplated that the self-scanning array of photodiodes may contain from about 60 to 2048, and preferably about 256 to 2048, individual photodiode elements per inch of object width, thereby permitting maximum data collection to produce a complete image or complete collection of image data

  9. Positioning calibration apparatus for transducers employed in nuclear reactor vessel inspection apparatus

    International Nuclear Information System (INIS)

    Elsner, H.J.

    1979-01-01

    Calibration apparatus for verifying the position and orientation of transducers used in nuclear reactor vessel inspection apparatus is disclosed. A tank, filled with water, the operating inspection medium, is fitted with a movable mounting assembly adapted to securely accommodate a transducer and the mounting assembly in which it is normally secured during an inspection procedure. The tank is also provided with a slidably mounted target positioned therein at a predetermined distance from the target which is selected to avoid the distortion effects in the near field of the transducer response. The calibration apparatus can be used to check the normal transducer mounting for either perpendicularity or angular orientation by moving the tank's mounting assembly via a lead screw with which it is threadingly engaged. 6 claims

  10. Application of InSAR and gravimetric surveys for developing construction codes in zones of land subsidence induced by groundwater extraction: case study of Aguascalientes, Mexico

    Directory of Open Access Journals (Sweden)

    J. Pacheco-Martínez

    2015-11-01

    Full Text Available Interferometric Synthetic Aperture Radar (InSAR has become a valuable tool for surface deformation monitoring, including land subsidence associated with groundwater extraction. Another useful tools for studying Earth's surface processes are geophysical methods such as Gravimetry. In this work we present the application of InSAR analysis and gravimetric surveying to generate valuable information for risk management related to land subsidence and surface faulting. Subsidence of the city of Aguascalientes, Mexico is presented as study case. Aguascalientes local governments have addressed land subsidence issues by including new requirements for new constructions projects in the State Urban Construction Code. Nevertheless, the resulting zoning proposed in the code is still subjective and not clearly defined. Our work based on gravimetric and InSAR surveys is aimed for improving the subsidence hazard zoning proposed in the State Urban Code in a more comprehensive way. The study includes a 2007–2011 ALOS InSAR time-series analysis of the Aguascalientes valley, an interpretation of the compete Bouguer gravimetric anomaly of the Aguascalientes urban area, and the application of time series and gravimetric anomaly maps for improve the subsidence hazard zoning of Aguascalientes City.

  11. Three years of high precision gravity measurements at the gravimetric station of Brasimone - Italy

    Directory of Open Access Journals (Sweden)

    G. Casula

    1998-06-01

    Full Text Available From August 1995 up to now, at the Enea Research Center of Brasimone, in the Italian Apennines between Bologna and Florence (Italy: 44º07'N, 11º.07'E, 890 m height, the superconducting gravimeter GWR model TT70 number T015 has been continuously recording the variation of the local gravity field, in the frame of the Global Geodynamics Project. The gravimetric laboratory, being a room of the disused nuclear power plant of Brasimone, is a very stable site, free from noise due to human activities. Data blocks of several months of continuous gravity records have been collected over a time span of three years, together with the meteorological data. The gravimeter has been calibrated at relative accuracy better than 0.3% with the aid of a mobile mass system, by imposed perturbations of the local gravity field and recording the gravimeter response. The results of this calibration technique were checked by two comparison experiments with absolute gravimeters performed during this period: the first, in May 1994 with the aid of the symmetrical rise and fall gravimeter of the Institute of Metrology Colonnetti of Turin, and the second in October 1997 involving an FG5 absolute gravimeter of the Institute de Physique du Globe of Strasbourg. The gravimeter signal was analysed to compute a high precision tidal model for Brasimone site. Starting from a set of gravimetric and atmospheric pressure data of high quality, relative to 46 months of observation, we performed the tidal analysis using Eterna 3.2 software to compute amplitudes, gravimetric factors and phases of the main waves of the Tamura catalogue. Finally a comparison experiment between two of the STS-1/VBB broadband seismometers of the MedNet project network and the gravity records relative to the Balleny Islands earthquake (March 25, 1998 were analysed to look for evidence of normal modes due to the free oscillations of the Earth.

  12. Gravimetric preparation and characterization of primary reference solutions of molybdenum and rhodium.

    Science.gov (United States)

    Kaltenbach, Angela; Noordmann, Janine; Görlitz, Volker; Pape, Carola; Richter, Silke; Kipphardt, Heinrich; Kopp, Gernot; Jährling, Reinhard; Rienitz, Olaf; Güttler, Bernd

    2015-04-01

    Gravimetrically prepared mono-elemental reference solutions having a well-known mass fraction of approximately 1 g/kg (or a mass concentration of 1 g/L) define the very basis of virtually all measurements in inorganic analysis. Serving as the starting materials of all standard/calibration solutions, they link virtually all measurements of inorganic analytes (regardless of the method applied) to the purity of the solid materials (high-purity metals or salts) they were prepared from. In case these solid materials are characterized comprehensively with respect to their purity, this link also establishes direct metrological traceability to The International System of Units (SI). This, in turn, ensures the comparability of all results on the highest level achievable. Several national metrology institutes (NMIs) and designated institutes (DIs) have been working for nearly two decades in close cooperation with commercial producers on making an increasing number of traceable reference solutions available. Besides the comprehensive characterization of the solid starting materials, dissolving them both loss-free and completely under strict gravimetric control is a challenging problem in the case of several elements like molybdenum and rhodium. Within the framework of the European Metrology Research Programme (EMRP), in the Joint Research Project (JRP) called SIB09 Primary standards for challenging elements, reference solutions of molybdenum and rhodium were prepared directly from the respective metals with a relative expanded uncertainty associated with the mass fraction of U rel(w) methods required to assist with the preparation and as dissemination tools.

  13. X-ray apparatus

    International Nuclear Information System (INIS)

    Tomita, Chuji.

    1980-01-01

    A principal object of the present invention is to provide an X-ray apparatus which is such that the distance between the surface of the patient's table and the floor on which the apparatus is installed is sufficiently small in the horizontal position of the patient's table of the roentgenographical pedestal and that the rotation of the pedestal from the horizontal position to a tilted position and further to the vertical position of the table can be carried out smoothly. (auth)

  14. Nuclear core baffling apparatus

    International Nuclear Information System (INIS)

    Cooper, F.W. Jr.; Silverblatt, B.L.; Knight, C.B.; Berringer, R.T.

    1979-01-01

    An apparatus for baffling the flow of reactor coolant fluid into and about the core of a nuclear reactor is described. The apparatus includes a plurality of longitudinally aligned baffle plates with mating surfaces that allow longitudinal growth with temperature increases while alleviating both leakage through the aligned plates and stresses on the components supporting the plates

  15. In-line gas chromatographic apparatus for measuring the hydrophobic micropore volume (HMV) and contaminant transformation in mineral micropores

    Energy Technology Data Exchange (ETDEWEB)

    Cheng Hefa [State Key Laboratory of Organic Geochemistry, Guangzhou Institute of Geochemistry, Chinese Academy of Sciences, Guangzhou 510640 (China); Reinhard, Martin, E-mail: reinhard@stanford.edu [Department of Civil and Environmental Engineering, Stanford University, Stanford, CA 94305-4020 (United States)

    2010-07-15

    Desorption of hydrophobic organic compounds from micropores is characteristically slow compared to surface adsorption and partitioning. The slow-desorbing mass of a hydrophobic probe molecule can be used to calculate the hydrophobic micropore volume (HMV) of microporous solids. A gas chromatographic apparatus is described that allows characterization of the sorbed mass with respect to the desorption rate. The method is demonstrated using a dealuminated zeolite and an aquifer sand as the model and reference sorbents, respectively, and trichloroethylene (TCE) as the probe molecule. A glass column packed with the microporous sorbent is coupled directly to a gas chromatograph that is equipped with flame ionization and electron capture detectors. Sorption and desorption of TCE on the sorbent was measured by sampling the influent and effluent of the column using a combination of switching and injection valves. For geosorbents, the HMV is quantified based on Gurvitsch's rule from the mass of TCE desorbed at a rate that is characteristic for micropores. Instrumental requirements, design considerations, hardware details, detector calibration, performance, and data analysis are discussed along with applications. The method is novel and complements traditional vacuum gravimetric and piezometric techniques, which quantify the total pore volume under vacuum conditions. The HMV is more relevant than the total micropore volume for predicting the fate and transport of organic contaminants in the subsurface. Sorption in hydrophobic micropores strongly impacts the mobility of organic contaminants, and their chemical and biological transformations. The apparatus can serve as a tool for characterizing microprous solids and investigating contaminant-solid interactions.

  16. In-line gas chromatographic apparatus for measuring the hydrophobic micropore volume (HMV) and contaminant transformation in mineral micropores

    International Nuclear Information System (INIS)

    Cheng Hefa; Reinhard, Martin

    2010-01-01

    Desorption of hydrophobic organic compounds from micropores is characteristically slow compared to surface adsorption and partitioning. The slow-desorbing mass of a hydrophobic probe molecule can be used to calculate the hydrophobic micropore volume (HMV) of microporous solids. A gas chromatographic apparatus is described that allows characterization of the sorbed mass with respect to the desorption rate. The method is demonstrated using a dealuminated zeolite and an aquifer sand as the model and reference sorbents, respectively, and trichloroethylene (TCE) as the probe molecule. A glass column packed with the microporous sorbent is coupled directly to a gas chromatograph that is equipped with flame ionization and electron capture detectors. Sorption and desorption of TCE on the sorbent was measured by sampling the influent and effluent of the column using a combination of switching and injection valves. For geosorbents, the HMV is quantified based on Gurvitsch's rule from the mass of TCE desorbed at a rate that is characteristic for micropores. Instrumental requirements, design considerations, hardware details, detector calibration, performance, and data analysis are discussed along with applications. The method is novel and complements traditional vacuum gravimetric and piezometric techniques, which quantify the total pore volume under vacuum conditions. The HMV is more relevant than the total micropore volume for predicting the fate and transport of organic contaminants in the subsurface. Sorption in hydrophobic micropores strongly impacts the mobility of organic contaminants, and their chemical and biological transformations. The apparatus can serve as a tool for characterizing microprous solids and investigating contaminant-solid interactions.

  17. In-line gas chromatographic apparatus for measuring the hydrophobic micropore volume (HMV) and contaminant transformation in mineral micropores.

    Science.gov (United States)

    Cheng, Hefa; Reinhard, Martin

    2010-07-15

    Desorption of hydrophobic organic compounds from micropores is characteristically slow compared to surface adsorption and partitioning. The slow-desorbing mass of a hydrophobic probe molecule can be used to calculate the hydrophobic micropore volume (HMV) of microporous solids. A gas chromatographic apparatus is described that allows characterization of the sorbed mass with respect to the desorption rate. The method is demonstrated using a dealuminated zeolite and an aquifer sand as the model and reference sorbents, respectively, and trichloroethylene (TCE) as the probe molecule. A glass column packed with the microporous sorbent is coupled directly to a gas chromatograph that is equipped with flame ionization and electron capture detectors. Sorption and desorption of TCE on the sorbent was measured by sampling the influent and effluent of the column using a combination of switching and injection valves. For geosorbents, the HMV is quantified based on Gurvitsch's rule from the mass of TCE desorbed at a rate that is characteristic for micropores. Instrumental requirements, design considerations, hardware details, detector calibration, performance, and data analysis are discussed along with applications. The method is novel and complements traditional vacuum gravimetric and piezometric techniques, which quantify the total pore volume under vacuum conditions. The HMV is more relevant than the total micropore volume for predicting the fate and transport of organic contaminants in the subsurface. Sorption in hydrophobic micropores strongly impacts the mobility of organic contaminants, and their chemical and biological transformations. The apparatus can serve as a tool for characterizing microporous solids and investigating contaminant-solid interactions. 2010 Elsevier B.V. All rights reserved.

  18. Determination of sulfate in thorium salts using gravimetric technique with previous thorium separation

    International Nuclear Information System (INIS)

    Silva, C.M. da; Pires, M.A.F.

    1994-01-01

    Available as short communication only. A simple analytical method to analyze sulfates in thorium salt, is presented. The method is based on the thorium separation as hydroxide. The gravimetric technique is used to analyze the sulfate in the filtered as barium sulfate. Using this method, the sulfate separation from thorium has been reach 99,9% yield, and 0,1% precision. This method is applied to thorium salts specifically thorium sulfate, carbonate and nitrate. (author). 5 refs, 2 tabs

  19. Comparison of gravimetric and gas chromatographic methods for assessing performance of textile materials against liquid pesticide penetration.

    Science.gov (United States)

    Shaw, Anugrah; Abbi, Ruchika

    2004-01-01

    Penetration of liquid pesticides through textile materials is a criterion for determining the performance of protective clothing used by pesticide handlers. The pipette method is frequently used to apply liquid pesticides onto textile materials to measure penetration. Typically, analytical techniques such as Gas Chromatography (GC) are used to measure percentage penetration. These techniques are labor intensive and costly. A simpler gravimetric method was developed, and tests were conducted to compare the gravimetric and GC methods of analysis. Three types of pesticide formulations and 4 fabrics were used for the study. Diluted pesticide formulations were pipetted onto the test specimens and percentage penetration was measured using the 2 methods. For homogeneous formulation, the results of the two methods were fairly comparable. However, due to the filtering action of the textile materials, there were differences in the percentage penetration between the 2 methods for formulations that were not homogeneous.

  20. Radioactive waste material melter apparatus

    Science.gov (United States)

    Newman, D.F.; Ross, W.A.

    1990-04-24

    An apparatus for preparing metallic radioactive waste material for storage is disclosed. The radioactive waste material is placed in a radiation shielded enclosure. The waste material is then melted with a plasma torch and cast into a plurality of successive horizontal layers in a mold to form a radioactive ingot in the shape of a spent nuclear fuel rod storage canister. The apparatus comprises a radiation shielded enclosure having an opening adapted for receiving a conventional transfer cask within which radioactive waste material is transferred to the apparatus. A plasma torch is mounted within the enclosure. A mold is also received within the enclosure for receiving the melted waste material and cooling it to form an ingot. The enclosure is preferably constructed in at least two parts to enable easy transport of the apparatus from one nuclear site to another. 8 figs.

  1. Radioactive waste material melter apparatus

    International Nuclear Information System (INIS)

    Newman, D.F.; Ross, W.A.

    1990-01-01

    An apparatus for preparing metallic radioactive waste material for storage is disclosed. The radioactive waste material is placed in a radiation shielded enclosure. The waste material is then melted with a plasma torch and cast into a plurality of successive horizontal layers in a mold to form a radioactive ingot in the shape of a spent nuclear fuel rod storage canister. The apparatus comprises a radiation shielded enclosure having an opening adapted for receiving a conventional transfer cask within which radioactive waste material is transferred to the apparatus. A plasma torch is mounted within the enclosure. A mold is also received within the enclosure for receiving the melted waste material and cooling it to form an ingot. The enclosure is preferably constructed in at least two parts to enable easy transport of the apparatus from one nuclear site to another. 8 figs

  2. Simplified method for gravimetric determination of zirconium or hafnium with α-hydroxy carboxylic acids

    International Nuclear Information System (INIS)

    Barbieri, R.S.; Rocha, J.C.; Terra, V.R.; Marques Netto, A.

    1989-01-01

    The conditions for gravimetric determination of zirconium or hafnium by glicoloc acids derivatives were studied by thermogravimetric analysis. The method utilized shownd that after precipitation, washing and drying of precipitates at 150 o C, the resulting solid was weighed in the form of [M (RCH(OH)COO) 4 ] (M = Zr, Hf; R + C 6 H 5 , β-C 10 H 7 , p-BrC 6 H 4 ). (author)

  3. Fractionation and rectification apparatus

    Energy Technology Data Exchange (ETDEWEB)

    Sauerwald, A

    1932-05-25

    Fractionation and rectifying apparatus with a distillation vessel and a stirring tube, drainage tubes leading from its coils to a central collecting tube, the drainage tubes being somewhat parallel and attached to the outer half of the stirring tube and partly on the inner half of the central collecting tube, whereby distillation and rectification can be effected in a single apparatus.

  4. 42 CFR 84.74 - Apparatus containers; minimum requirements.

    Science.gov (United States)

    2010-10-01

    ... 42 Public Health 1 2010-10-01 2010-10-01 false Apparatus containers; minimum requirements. 84.74...-Contained Breathing Apparatus § 84.74 Apparatus containers; minimum requirements. (a) Apparatus may be equipped with a substantial, durable container bearing markings which show the applicant's name, the type...

  5. Specifications for surface reaction analysis apparatus

    International Nuclear Information System (INIS)

    Teraoka, Yuden; Yoshigoe, Akitaka

    2001-03-01

    A surface reaction analysis apparatus was installed at the JAERI soft x-ray beamline in the SPring-8 as an experimental end-station for the study of surface chemistry. The apparatus is devoted to the study concerning the influence of translational kinetic energy of incident molecules to chemical reactions on solid surfaces with gas molecules. In order to achieve the research purpose, reactive molecular scattering experiments and photoemission spectroscopic measurements using synchrotron radiation are performed in that apparatus via a supersonic molecular beam generator, an electron energy analyzer and a quadrupole mass analyzer. The detail specifications for the apparatus are described in this report. (author)

  6. Determination of molybdenum by the gravimetric plumbate method (with the molybdenum content from 50 % and above)

    International Nuclear Information System (INIS)

    Stepin, V.V.; Kurbatova, V.I.; Fedorova, N.D.

    1980-01-01

    A gravimetric method of molybdenum determination in ferromolybdenum (Mo content from 50% and higher) after its dissolving in HNO 3 is developed. The method is based on Mo deposition in acetic acid solution in the form of molybdenum oxide lead after separation of Fe and other interfering elements with sodium hydroxide [ru

  7. Radioactive waste processing apparatus

    Science.gov (United States)

    Nelson, R.E.; Ziegler, A.A.; Serino, D.F.; Basnar, P.J.

    1985-08-30

    Apparatus for use in processing radioactive waste materials for shipment and storage in solid form in a container is disclosed. The container includes a top, and an opening in the top which is smaller than the outer circumference of the container. The apparatus includes an enclosure into which the container is placed, solution feed apparatus for adding a solution containing radioactive waste materials into the container through the container opening, and at least one rotatable blade for blending the solution with a fixing agent such as cement or the like as the solution is added into the container. The blade is constructed so that it can pass through the opening in the top of the container. The rotational axis of the blade is displaced from the center of the blade so that after the blade passes through the opening, the blade and container can be adjusted so that one edge of the blade is adjacent the cylindrical wall of the container, to insure thorough mixing. When the blade is inside the container, a substantially sealed chamber is formed to contain vapors created by the chemical action of the waste solution and fixant, and vapors emanating through the opening in the container. The chamber may be formed by placing a removable extension over the top of the container. The extension communicates with the apparatus so that such vapors are contained within the container, extension and solution feed apparatus. A portion of the chamber includes coolant which condenses the vapors. The resulting condensate is returned to the container by the force of gravity.

  8. Switched-mode power supply apparatus and method

    NARCIS (Netherlands)

    2013-01-01

    The present invention relates to a switched-mode power supply apparatus and a corresponding method. For an effective compensation of non-linearities caused by dead- time and voltage drops in the switching power amplifier of the apparatus, an apparatus is proposed comprising a switching power

  9. Switched-mode power supply apparatus and method

    NARCIS (Netherlands)

    2013-01-01

    The present invention relates to a switched-mode power supply apparatus and a corresponding method. For an effective compensation of non-linearities caused by dead-time and voltage drops in the switching power amplifier of the apparatus, an apparatus is proposed comprising a switching power

  10. Comparison of the gravimetric, phenol red, and 14C-PEG-3350 methods to determine water absorption in the rat single-pass intestinal perfusion model

    OpenAIRE

    Sutton, Steven C.; Rinaldi, M. T. S.; Vukovinsky, K. E.

    2001-01-01

    This study was undertaken to determine whether the gravimetric method provided an accurate measure of water flux correction and to compare the gravimetric method with methods that employ nonabsorbed markers (eg, phenol red and 14C-PEG-3350). Phenol red, 14C-PEG-3350, and 4-[2-[[2-(6-amino-3-pyridinyl)-2-hydroxyethyl]amino]ethoxy]-methyl ester, (R)-benzene acetic acid (Compound I) were co-perfused in situ through the jejunum of 9 anesthetized rats (single-pass intestinal perfusion [SPIP]). Wat...

  11. EXTRACTION APPARATUS

    Science.gov (United States)

    Ballard, A.E.; Brigham, H.R.

    1958-10-28

    An apparatus whereby relatlvely volatile solvents may be contacted with volatile or non-volatile material without certaln attendant hazards is described. A suitable apparatus for handling relatively volatlle liqulds may be constructed comprising a tank, and a closure covering the tank and adapted to be securely attached to an external suppont. The closure is provided with a rigidly mounted motor-driven agitator. This agitator is connected from the driving motor lnto the lnterlor of the tank through a gland adapted to be cooled witb inert gas thereby eliminating possible hazard due to frictional heat. The closure is arranged so that the tank may be removed from it without materially dlsturbing the closure which, as described, carrles the motor driven agitator and other parts.

  12. Apparatus for ultrasonic nebulization

    International Nuclear Information System (INIS)

    Olson, K.W.; Haas, W.J. Jr.; Fassel, V.A.

    1978-01-01

    An improved apparatus is described for ultrasonic nebulization of liquid samples or suspensions in which the piezoelectric transducer is protected from chemical attack and erosion. The transducer is protected by being bonded to the inner surface of a glass plate which forms one end wall of a first hollow body provided with apparatus for circulating a fluid for cooling and stabilizing the transducer. The glass plate, which is one-half wavelength in thickness to provide an acoustically coupled outer nebulizing surface, seals an opening in a second hollow body which encloses an aerosol mixing chamber. The second body includes apparatus for delivering the sample solution to the nebulizing surface, a gas inlet for providing a flow of carrier gas for transporting the aerosol of the nebulized sample and an aerosol outlet

  13. A binder-free NiCo2O4 nanosheet/3D elastic N-doped hollow carbon nanotube sponge electrode with high volumetric and gravimetric capacitances for asymmetric supercapacitors.

    Science.gov (United States)

    Tong, Hao; Yue, Shihong; Lu, Liang; Jin, Fengqiao; Han, Qiwei; Zhang, Xiaogang; Liu, Jie

    2017-11-09

    To increase the volumetric and gravimetric capacitances of supercapacitors, a new class of electrode materials with high electrochemical activity and favorable structures is extremely desired. In this work, a hollow novel nitrogen-doped 3D elastic single-walled carbon nanotube sponge (NSCS) which is ultra lightweight with the lowest density of 0.8 mg cm -3 , and has a high open surface structure for electrolyte accessibility and excellent compressible properties as the electrode scaffold has been successfully fabricated by the pyrolysis method which could produce the carbon nanotube sponge easily on a large scale without high-cost and time-consuming processes. Moreover, a NiCo 2 O 4 nanosheet supported on the NSCS has been successfully fabricated. The highest volumetric and gravimetric capacitance of this electrode is 790 F cm -3 at 1.43 g cm -3 and 1618 F g -1 at 0.54 g cm -3 with excellent cycling stability. The density of NiCo 2 O 4 /NSCS electrode was adjusted by mechanical compression and the most favorable density of the film for both high volumetric and gravimetric capacitances obtained was 1.21 g cm -3 . The thick NiCo 2 O 4 /NSCS film of 72 μm has been fabricated at this favorable density, presenting both high volumetric and gravimetric capacitances of 597 F cm -3 and 1074 F g -1 at 1 A g -1 , respectively, indicating that the structure of the NSCS is extremely feasible for obtaining a thick film electrode with excellent volumetric and gravimetric capacitances. Furthermore, an asymmetric supercapacitor of NiCo 2 O 4 /NSCS//NGN/CNTs was fabricated, exhibiting a high gravimetric energy density of 47.65 W h kg -1 at 536 W kg -1 and a volumetric energy density of 33.44 W h L -1 at 376.16 W L -1 .

  14. Test sample handling apparatus

    International Nuclear Information System (INIS)

    1981-01-01

    A test sample handling apparatus using automatic scintillation counting for gamma detection, for use in such fields as radioimmunoassay, is described. The apparatus automatically and continuously counts large numbers of samples rapidly and efficiently by the simultaneous counting of two samples. By means of sequential ordering of non-sequential counting data, it is possible to obtain precisely ordered data while utilizing sample carrier holders having a minimum length. (U.K.)

  15. Infrared microscope inspection apparatus

    Science.gov (United States)

    Forman, Steven E.; Caunt, James W.

    1985-02-26

    Apparatus and system for inspecting infrared transparents, such as an array of photovoltaic modules containing silicon solar cells, includes an infrared microscope, at least three sources of infrared light placed around and having their axes intersect the center of the object field and means for sending the reflected light through the microscope. The apparatus is adapted to be mounted on an X-Y translator positioned adjacent the object surface.

  16. A gravimetric and an X-ray fluorescence method for the determination of rubidium in Rb2U(SO4)3

    International Nuclear Information System (INIS)

    Mudher, K.D.S.; Krishnan, K.; Jayadevan, N.C.

    1993-01-01

    Chemical characterization of rubidium uranium(IV) trisulfate, RB 2 U(SO 4 ) 3 , a new chemical assay standard for uranium requires accurate analysis of rubidium. A gravimetric and an X-ray fluorescence method (XRF) for the determination of rubidium in this compound are described. In the gravimetric method, rubidium is determined as Rb 2 Na[Co(NO 2 ) 6 ].H 2 O without separating uranium with a precision of the order of ±0.5%. In the XRF method, the concentration ratio of rubidium to uranium, C Rb /C U , is determined in the solid samples by the binary ratio method using calibration between intensity ratios (I Rb /I U ) and concentration ratios (C Rb /C U ). (author) 6 refs.; 2 figs.; 3 tabs

  17. GRAVIMETRIC-DETERMINATION OF THE WATER CONCENTRATION IN WHOLE-BLOOD, PLASMA AND ERYTHROCYTES AND CORRELATIONS WITH HEMATOLOGICAL AND CLINICOCHEMICAL PARAMETERS

    NARCIS (Netherlands)

    LIJNEMA, TH; HUIZENGA, [No Value; JAGER, J; MACKOR, AJ; GIPS, CH

    1993-01-01

    We have assessed gravimetric methods for determination of intravascular water, established whole blood-, plasma- and erythrocyte water reference values in a healthy volunteer group (n = 97, 48 females) and correlated these variables with 30 simultaneous hematological, clinicochemical and body

  18. Offshore gravimetric and subsidence monitoring

    Energy Technology Data Exchange (ETDEWEB)

    Stenvold, Torkjell

    2008-06-15

    are discussed in Stenvold et al. (Chapter 2). A latitude dependence of the calibration scale factors of Scintrex gravimeters is shown for the first time. Chapter 5 contains the article 'Constraints on the in situ density of CO2 within the Utsira formation from time-lapse seafloor gravity measurements' by Nooner et al. (2007), published in the International Journal of Greenhouse Gas Control. In this article gravity measurements made on 30 seafloor stations above the CO2 bubble in 2002 and 2005 have been used to constrain the in-situ density of CO2 for models derived from seismic. The gravity responses of various numerical models are compared for the1999 to 2001 period. Note that time-lapse seismic for the 2002-2005 period was not available when this article was written. Chapter 6 contains the article 'Monitoring both gas production and CO2 injection at the Sleipner field using time-lapse gravimetry' by Alnes et al., submitted 29 February 2008 to Geophysics. This is a renewed analysis of the same gravity data as in the article by Nooner et al. (Chapter 5). Recently available 4D seismic, a more updated reservoir simulation model, and reprocessed gravity and pressure data give a new estimate of CO2 density. The observed gravity response between 2002 and 2005 from the underlying Ty Formation is shown for the first time. Chapter 7 contains the article 'Gravimetric monitoring of gas production from the Troll field' by Eiken et al., submitted 3 April 2008 to Geophysics. The gravity data is used to map and quantify water influx on Troll between 2002 and 2005. There is good agreement with well data and the amount of water influx agrees with material balance calculations. Chapter 8 contains the article 'Gravimetric monitoring of gas reservoir water influx' a combined flow- and gravity-modeling approach' by Stenvold et al., and was accepted for publication in January 2008 by Geophysics. It is to appear in an upcoming special section on

  19. Support of nuclear fusion apparatus

    International Nuclear Information System (INIS)

    Watarai, Tetsuo; Ito, Yutaka.

    1975-01-01

    Object: To integrally form a bed for a body for supporting a vacuum container, coil and the like and a bed for a current transformer for supporting the current transformer prior to installation thereof on the floor thereby facilitating assembly and installation. Structure: To provide a base common to a current transformer bed and a body bed without direct installation thereof on the floor. Prior to installation of the current transformer bed and body bed, they are fastened to the base by means of bolts and welded integrally, and the thus formed base is fixed to the floor by means of anchor bolts. Since the current transformer bed and the body bed are formed integrally through the common base, apparatus may easily be carried in and disassembling and re-assembling of apparatus become unnecessary when installed. Further, since the positional relation of the current transformer bed and body bed does not depend on accuracy at the time of installation but depends on accuracy when apparatus manufactured, the toroidal type nuclear fusion apparatus of good accuracy may be obtained. (Yoshihara, H.)

  20. Highly Selective Polypyrrole MIP-Based Gravimetric and Electrochemical Sensors for Picomolar Detection of Glyphosate

    Directory of Open Access Journals (Sweden)

    Zouhour Mazouz

    2017-11-01

    Full Text Available There is a global debate and concern about the use of glyphosate (Gly as an herbicide. New toxicological studies will determine its use in the future under new strict conditions or its replacement by alternative synthetic or natural herbicides. In this context, we designed biomimetic polymer sensing layers for the selective molecular recognition of Gly. Towards this end, complementary surface acoustic wave (SAW and electrochemical sensors were functionalized with polypyrrole (PPy-imprinted polymer for the selective detection of Gly. Their corresponding limits of detection were on the order of 1 pM, which are among the lowest values ever reported in literature. The relevant dissociation constants between PPy and Gly were estimated at [Kd1 = (0.7 ± 0.3 pM and Kd2 = (1.6 ± 1.4 µM] and [Kd1 = (2.4 ± 0.9 pM and Kd2 = (0.3 ± 0.1 µM] for electrochemical and gravimetric measurements, respectively. Quantum chemical calculations permitted to estimate the interaction energy between Gly and PPy film: ΔE = −145 kJ/mol. Selectivity and competitivity tests were investigated with the most common pesticides. This work conclusively shows that gravimetric and electrochemical results indicate that both MIP-based sensors are perfectly able to detect and distinguish glyphosate without any ambiguity.

  1. Air-cleaning apparatus

    International Nuclear Information System (INIS)

    Howard, A.G.

    1981-01-01

    An air-cleaning, heat-exchange apparatus includes a main housing portion connected by means of an air inlet fan to the kitchen exhaust stack of a restaurant. The apparatus includes a plurality of heat exchangers through which a heat-absorptive fluid is circulated, simultaneously, by means of a suitable fluid pump. These heat exchangers absorb heat from the hot exhaust gas, out of the exhaust stack of the restaurant, which flows over and through these heat exchangers and transfers this heat to the circulating fluid which communicates with remote heat exchangers. These remote heat exchangers further transfer this heat to a stream of air, such as that from a cold-air return duct for supplementing the conventional heating system of the restaurant. Due to the fact that such hot exhaust gas is heavily grease laden , grease will be deposited on virtually all internal surfaces of the apparatus which this exhaust gas contacts. Consequently, means are provided for spraying these contacted internal surfaces , as well as the hot exhaust gas itself, with a detergent solution in which the grease is soluble, thereby removing grease buildup from these internal surfaces

  2. A Study on Test Technology to Diagnose the Power Apparatus

    Energy Technology Data Exchange (ETDEWEB)

    Kim, K H; Kang, Y S; Jeon, Y K; Lee, W Y; Kang, D S; Kyu, H S; Sun, J H; Jo, K H [Korea Electrotechnology Research Institute (Korea, Republic of); Jung, J S; Mun, Y T; Lee, K H; Jung, E H; Kim, J H [Korea Water Resources Corporation (Korea, Republic of)

    1997-02-01

    In this study, we have educated KOWACO(Korea Water Resources Corporation) specialists about the insulation diagnostic technology and trained them the insulation diagnostic test and estimation method of power apparatus. The main results of this study are as follows; A. Education of basic high-voltage engineering. B. Research of insulation characteristic and deterioration mechanism in power apparatus C. Discussion on high-voltage test standard specifications. D. Study on insulation deterioration diagnostics in power apparatus. E. Field testing of insulation diagnosis in power apparatus. F. Engineering of insulation diagnostic testing apparatus to diagnose power apparatus. KOWACO specialists are able to diagnose insulation diagnostic test of power apparatus through this study. As they have instruments to diagnose power apparatus, they can do the test and estimation of the power apparatus insulation diagnosis. (author). refs., figs., tabs.

  3. Apparatus Named after Our Academic Ancestors--I

    Science.gov (United States)

    Greenslade, Thomas B., Jr.

    2010-01-01

    Let us now praise famous physicists, and the apparatus named after them, with apologies to the writer of Ecclesiastes. I once compiled a list of about 300 pieces of apparatus known to us as X's Apparatus. Some of the values of X are familiar, like Wheatstone and Kelvin and Faraday, but have you heard of Pickering or Rhumkorff or Barlow? In an…

  4. 21 CFR 886.4100 - Radiofrequency electrosurgical cautery apparatus.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Radiofrequency electrosurgical cautery apparatus... SERVICES (CONTINUED) MEDICAL DEVICES OPHTHALMIC DEVICES Surgical Devices § 886.4100 Radiofrequency electrosurgical cautery apparatus. (a) Identification. A radiofrequency electrosurgical cautery apparatus is an AC...

  5. Alternatives to the gravimetric method for quantification of diesel particulate matter near the lower level of detection.

    Science.gov (United States)

    Swanson, Jacob; Kittelson, David; Pui, David; Watts, Winthrop

    2010-10-01

    This paper is part of the Journal of the Air & Waste Management Association's 2010 special issue on combustion aerosol measurements. The issue is a combination of papers that synthesize and evaluate ideas and perspectives that were presented by experts at a series of workshops sponsored by the Coordinating Research Council that aimed to evaluate the current and future status of diesel particulate matter (DPM) measurement. Measurement of DPM is a complex issue with many stakeholders, including air quality management and enforcement agencies, engine manufacturers, health experts, and climatologists. Adoption of the U.S. Environmental Protection Agency 2007 heavy-duty engine DPM standards posed a unique challenge to engine manufacturers. The new standards reduced DPM emissions to the point that improvements to the gravimetric method were required to increase the accuracy and the sensitivity of the measurement. Despite these improvements, the method still has shortcomings. The objectives of this paper are to review the physical and chemical properties of DPM that make gravimetric measurement difficult at very low concentrations and to review alternative metrics and methods that are potentially more accurate, sensitive, and specific. Particle volatility, size, surface area, and number metrics are considered, as well as methods to quantify them. Although the authors believe that an alternative method is required to meet the needs of engine manufacturers, the methods reviewed in the paper are applicable to other areas where the gravimetric method detection limit is approached and greater accuracy and sensitivity are required. The paper concludes by suggesting a method to measure active surface area, combined with a method to separate semi-volatile and solid fractions to further increase the specificity of the measurement, has potential for reducing the lower detection limit of DPM and enabling engine manufacturers to reduce DPM emissions in the future.

  6. Gravimetric determination of carbon in uranium-plutonium carbide materials

    International Nuclear Information System (INIS)

    Kavanaugh, H.J.; Dahlby, J.W.; Lovell, A.P.

    1979-12-01

    A gravimetric method for determining carbon in uranium-plutonium carbide materials was developed to analyze six samples simultaneously. The samples are burned slowly in an oxygen atmosphere at approximately 900 0 C, and the gases generated are passed through Schuetze's oxidizing reagent (iodine pentoxide on silica gel) to assure quantitative oxidation of the CO to CO 2 . The CO 2 is collected on Ascarite and weighed. This method was tested using a tungsten carbide reference material (NBS-SRM-276) and a (U,Pu)C sample. For 42 analyses of the tungsten carbide, which has a certified carbon content of 6.09%, an average value of 6.09% was obtained with a standard deviation of 0.01 7 % or a relative standard deviation of 0.28%. For 17 analyses of the (U,Pu)C sample, an average carbon content of 4.97% was found with a standard deviation of 0.01 2 % or a relative standard deviation of 0.24%

  7. APPARATUS FOR ELECTRON BEAM HEATING CONTROL

    Science.gov (United States)

    Jones, W.H.; Reece, J.B.

    1962-09-18

    An improved electron beam welding or melting apparatus is designed which utilizes a high voltage rectifier operating below its temperature saturation region to decrease variations in electron beam current which normally result from the gas generated in such apparatus. (AEC)

  8. Uranium dioxide calcining apparatus

    International Nuclear Information System (INIS)

    Cole, E.A.; Peterson, R.S.

    1978-01-01

    This invention relates to an improved continuous calcining apparatus for consistently and controllably producing from calcinable reactive solid compounds of uranium, such as ammonium diuranate, uranium dioxide (UO 2 ) having an oxygen to uranium ratio of less than 2.2. The apparatus comprises means at the outlet end of a calciner kiln for receiving hot UO 2 , means for cooling the UO 2 to a temperature of below 100 deg C and conveying the cooled UO 2 to storage or to subsequent UO 2 processing apparatus where it finally comes into contact with air, the means for receiving cooling and conveying being sealed to the outlet end of the calciner and being maintained full of UO 2 and so operable as to exclude atmospheric oxygen from coming into contact with any UO 2 which is at elevated temperatures where it would readily oxidize, without the use of extra hydrogen gas in said means. (author)

  9. [Evaluation of the AOAC 985.29 enzimic gravimetric method for determination of dietary fiber in oat and corn grains].

    Science.gov (United States)

    da Silva, Leila Picolli; Ciocca, Maria de Lourdes Santorio; Furlong, Eliana Badiale

    2003-12-01

    The precision attributes and use of the enzymatic-gravimetric method of Prosky et al. (1992) (AOAC 985.29) were evaluated using corn (BR 5202 Pampa) and oat (UFRGS 15) samples. The effect of laboratory batches carried out in different days were evaluated in six laboratory batches, using for each material one duplicate for total fiber (FT) determination, one duplicate for insoluble fiber (FI) determination and blank ones for FT and for FI (both in duplicate). In order to characterize repetitive aspects, five other FT and FI determinations added to each sample were evaluated, summing up 11 data. The low coefficients of variation in the first six batches were considered acceptable as an expression of expected total intralaboratory variation. The repetitive of the method was considered good for FT determinations (CVs gravimetric corrections varies with the kind of the sample and is especially influenced by the protein content.

  10. First Release of Gravimetric Geoid Model over Saudi Arabia Based on Terrestrial Gravity and GOCE Satellite Data: KSAG01

    Science.gov (United States)

    Alothman, Abdulaziz; Elsaka, Basem

    2016-04-01

    A new gravimetric quasi-geoid, known as KSAG0, has been developed recently by Remove-Compute-Restore techniques (RCR), provided by the GRAVSOFT software, using gravimetric free air anomalies. The terrestrial gravity data used in this computations are: 1145 gravity field anomalies observed by ARAMCO (Saudi Arabian Oil Company) and 2470 Gravity measurements from BGI (Bureau Gravimétrique International). The computations were carried out implementing the least squares collocation method through the RCR techniques. The KSAG01 is based on merging in addition to the terrestrial gravity observations, GOCE satellite model (Eigen-6C4) and global gravity model (EGM2008) have been utilized in the computations. The long, medium and short wavelength spectrum of the height anomalies were compensated from Eigen-6C4 and EGM2008 geoid models truncated up to Degree and order (d/o) up to 2190. KSAG01 geoid covers 100 per cent of the kingdom, with geoid heights range from - 37.513 m in the southeast to 23.183 m in the northwest of the country. The accuracy of the geoid is governed by the accuracy, distribution, and spacing of the observations. The standard deviation of the predicted geoid heights is 0.115 m, with maximum errors of about 0.612 m. The RMS of geoid noise ranges from 0.019 m to 0.04 m. Comparison of the predicted gravimetric geoid with EGM, GOCE, and GPS/Levelling geoids, reveals a considerable improvements of the quasi-geoid heights over Saudi Arabia.

  11. 21 CFR 868.5165 - Nitric oxide administration apparatus.

    Science.gov (United States)

    2010-04-01

    ... apparatus. (a) Identification. The nitric oxide administration apparatus is a device used to add nitric oxide to gases that are to be breathed by a patient. The nitric oxide administration apparatus is to be used in conjunction with a ventilator or other breathing gas administration system. (b) Classification...

  12. Dosimeter charging apparatus

    International Nuclear Information System (INIS)

    Reuter, F.A.; Moorman, Ch.J.

    1985-01-01

    An apparatus for charging a dosimeter which has a capacitor connected between first and second electrodes and a movable electrode in a chamber electrically connected to the first electrode. The movable electrode deflects varying amounts depending upon the charge present on said capacitor. The charger apparatus includes first and second charger electrodes couplable to the first and second dosimeter electrodes. To charge the dosimeter, it is urged downwardly into a charging socket on the charger apparatus. The second dosimeter electrode, which is the dosimeter housing, is electrically coupled to the second charger electrode through a conductive ring which is urged upwardly by a spring. As the dosimeter is urged into the socket, the ring moves downwardly, in contact with the second charger electrode. As the dosimeter is further urged downwardly, the first dosimeter electrode and first charger electrode contact one another, and an insulator post carrying the first and second charger electrodes is urged downwardly. Downward movement of the post effects the application of a charging potential between the first and second charger electrodes. After the charging potential has been applied, the dosimeter is moved further into the charging socket against the force of a relatively heavy biasing spring until the dosimeter reaches a mechanical stop in the charging socket

  13. Hydraulic Apparatus for Mechanical Testing of Nuts

    Science.gov (United States)

    Hinkel, Todd J.; Dean, Richard J.; Hacker, Scott C.; Harrington, Douglas W.; Salazar, Frank

    2004-01-01

    The figure depicts an apparatus for mechanical testing of nuts. In the original application for which the apparatus was developed, the nuts are of a frangible type designed for use with pyrotechnic devices in spacecraft applications in which there are requirements for rapid, one-time separations of structures that are bolted together. The apparatus can also be used to test nonfrangible nuts engaged without pyrotechnic devices. This apparatus was developed to replace prior testing systems that were extremely heavy and immobile and characterized by long setup times (of the order of an hour for each nut to be tested). This apparatus is mobile, and the setup for each test can now be completed in about five minutes. The apparatus can load a nut under test with a static axial force of as much as 6.8 x 10(exp 5) lb (3.0 MN) and a static moment of as much as 8.5 x 10(exp 4) lb in. (9.6 x 10(exp 3) N(raised dot)m) for a predetermined amount of time. In the case of a test of a frangible nut, the pyrotechnic devices can be exploded to break the nut while the load is applied, in which case the breakage of the nut relieves the load. The apparatus can be operated remotely for safety during an explosive test. The load-generating portion of the apparatus is driven by low-pressure compressed air; the remainder of the apparatus is driven by 110-Vac electricity. From its source, the compressed air is fed to the apparatus through a regulator and a manually operated valve. The regulated compressed air is fed to a pneumatically driven hydraulic pump, which pressurizes oil in a hydraulic cylinder, thereby causing a load to be applied via a hydraulic nut (not to be confused with the nut under test). During operation, the hydraulic pressure is correlated with the applied axial load, which is verified by use of a load cell. Prior to operation, one end of a test stud (which could be an ordinary threaded rod or bolt) is installed in the hydraulic nut. The other end of the test stud passes

  14. Radiative Gasification Apparatus

    Data.gov (United States)

    Federal Laboratory Consortium — This apparatus, developed at EL, determines gasification rate (mass loss rate) of a horizontally oriented specimen exposed in a nitrogen environment to a controlled...

  15. Electroplating method and apparatus

    International Nuclear Information System (INIS)

    Looney, R.B.; Smith, W.E.L.

    1978-01-01

    Disclosed is an apparatus for high speed electroplating or anodizing tubular members such as nuclear reactor fuel elements. A loading arm positions the member on a base for subsequent support by one of two sets of electrical contacts. A carriage assembly positions electrodes into and around the member. Electrolyte is pumped between the electrodes and the member while electric current is applied. Programmed controls sequentially employ each of the two sets of contacts to expose all surfaces of the member to the electrolyte. The member is removed from the apparatus by an unloading arm

  16. Electroplating method and apparatus

    Science.gov (United States)

    Looney, Robert B.; Smith, William E. L.

    1978-06-20

    An apparatus for high speed electroplating or anodizing tubular members such as nuclear reactor fuel elements. A loading arm positions the member on a base for subsequent support by one of two sets of electrical contacts. A carriage assembly positions electrodes into and around the member. Electrolyte is pumped between the electrodes and the member while electric current is applied. Programmed controls sequentially employ each of the two sets of contacts to expose all surfaces of the member to the electrolyte. The member is removed from the apparatus by an unloading arm.

  17. Laser metrology for a next generation gravimetric mission

    Science.gov (United States)

    Mottini, Sergio; Biondetti, Giorgio; Cesare, Stefano; Castorina, Giuseppe; Musso, Fabio; Pisani, Marco; Leone, Bruno

    2017-11-01

    Within the ESA technology research project "Laser Interferometer High Precision tracking for LEO", Thales Alenia Space Italia is developing a laser metrology system for a Next Generation Gravimetric Mission (NGGM) based on satellite-to-satellite tracking. This technique is based on the precise measurement of the displacement between two satellites flying in formation at low altitude for monitoring the variations of Earth's gravity field at high resolution over a long time period. The laser metrology system that has been defined for this mission consists of the following elements: • an heterodyne Michelson interferometer for measuring the distance variation between retroreflectors positioned on the two satellites; • an angle metrology for measuring the orientation of the laser beam in the reference frames of the two satellites; • a lateral displacement metrology for measuring the deviations of the laser beam axis from the target retro-reflector. The laser interferometer makes use of a chopped measurement beam to avoid spurious signals and nonlinearity caused by the unbalance between the strong local beam and the weak return beam. The main results of the design, development and test activities performed on the breadboard of the metrology system are summarized in this paper.

  18. The Acoustical Apparatus of Rudolph Koenig.

    Science.gov (United States)

    Greenslade, Thomas B., Jr.

    1992-01-01

    Discusses the history of Rudolph Koenig's contribution to the development of acoustical apparatus. Contributions include the clock fork to determine absolute acoustic frequencies, a forerunner of the oscilloscope called the manometric flame, and an acoustic interference apparatus used in the Fourier synthesis of musical sounds. (MDH)

  19. BROACHING AND TUBE-INSTALLING APPARATUS

    Science.gov (United States)

    Frantz, C.E.; Cawley, W.E.

    1961-05-16

    An apparatus is given for sizing long holes in graphite bodies. The apparatus comprises a shaft having 3 spiral broach cutting elements and a straight broach cutting element rotatably mounted thereon. The broach cutting elements are keyed to each other in end to end relationship with the straight broach cutting element at one end of the shaft. The spiral broach cutting elements when considered toward the straight broach cutting element increase in diameter and the cutting teeth thereon increase in lead angle. The straight broach cutting element, when considered in the same direction, increases in diameter from the minimum to maximum diameters of the spiral broach cutting elements. No longitudinal movement of the broach cutting elements is permitted on the shsft snd means are provided for the removal of chips from the apparatus.

  20. Metal-Organic Frameworks for Resonant-Gravimetric Detection of Trace-Level Xylene Molecules.

    Science.gov (United States)

    Xu, Tao; Xu, Pengcheng; Zheng, Dan; Yu, Haitao; Li, Xinxin

    2016-12-20

    As one of typical VOCs, xylene is seriously harmful to human health. Nowadays, however, there is really lack of portable sensing method to directly detect environmental xylene that has chemical inertness. Especially when the concentration of xylene is lower than the human olfactory threshold of 470 ppb, people are indeed hard to be aware of and avoid this harmful vapor. Herein the metal-organic framework (MOF) of HKUST-1 is first explored for sensing to the nonpolar molecule of p-xylene. And the sensing mechanism is identified that is via host-guest interaction of MOF with xylene molecule. By loading MOFs on mass-gravimetric resonant-cantilevers, sensing experiments for four MOFs of MOF-5, HKUST-1, ZIF-8, and MOF-177 approve that HKUST-1 has the highest sensitivity to p-xylene. The resonant-gravimetric sensing experiments with our HKUST-1 based sensors have demonstrated that trace-level p-xylene of 400 ppb can be detected that is lower than the human olfactory threshold of 470 ppb. We analyze that the specificity of HKUST-1 to xylene comes from Cu 2+ -induced moderate Lewis acidity and the "like dissolves like" interaction of the benzene ring. In situ diffuse reflectance infrared Fourier transform spectroscopy (DRIFTS) is used to elucidate the adsorbing/sensing mechanism of HKUST-1 to p-xylene, where p-xylene adsorbing induced blue-shift phenomenon is observed that confirms the sensing mechanism. Our study also indicates that the sensor shows good selectivity to various kinds of common interfering gases. And the long-term repeatability and stability of the sensing material are also approved for the usage/storage period of two months. This research approves that the MOF materials exhibit potential usages for high performance chemical sensors applications.

  1. Monitoring apparatus

    International Nuclear Information System (INIS)

    Keats, A.B.

    1981-01-01

    An improved monitoring apparatus for use with process plants, such as nuclear reactors, is described. System failure in the acquisition of data from the plant, owing to stuck signals, is avoided by arranging input signals from transducers in the plant in a test pattern. (U.K.)

  2. 47 CFR 32.2311 - Station apparatus.

    Science.gov (United States)

    2010-10-01

    ... FOR TELECOMMUNICATIONS COMPANIES Instructions for Balance Sheet Accounts § 32.2311 Station apparatus... company shall prepare a list of station apparatus which shall be used as its list of disposition units for... technicians, and others, shall be included in Account 2114, Tools and other work equipment, Account 2220...

  3. low-cost apparatus from locally available materials for teaching

    African Journals Online (AJOL)

    unesco

    twofold: i) to design and produce appropriate low cost apparatus from locally .... How are the low-cost and manufactured apparatus compared in terms of cost and efficiency? ... BASIC TOOLS FOR THE LOW COST APPARATUS PRODUCTION.

  4. Thermo Gravimetric and Differential Thermal Analysis of Clay of Western Rajasthan (india)

    Science.gov (United States)

    Shekhawat, M. S.

    The paper presents the study of thermo gravimetric and differential thermal analysis of blended clay. Western part of Rajasthan (India) is rich resource of Ball clays and it is mainly used by porcelain, sanitary ware, and tile industry. The quality and grade of clay available in the region vary from one deposit to other. To upgrade the fired colour and strength properties, different variety of clays may be blended together. The paper compares the results of thermal analysis one of blended clay B2 with reference clay of Ukraine which is imported by industries owners. The result revealed that the blended clay is having mineral kaolinite while the Ukrainian clay is Halloysite.

  5. [Determination of total, soluble and insoluble dietary fiber in foods by enzymatic-gravimetric method].

    Science.gov (United States)

    Yang, X; Yang, Y; Zhou, R; Bian, L

    2001-11-01

    For studying the contents of dietary fiber in general foods and functional foods, a enzymatic-gravimetric method recommended by AOAC was established in our laboratory. The method for the determination of total, soluble and insoluble dietary fiber in foods and functional foods could be used for many other kind of foods. The relative standard deviations (RSD) of reproducibility between-run and within-run were 2.04%-7.85%, 3.42%-55.23% respectively. The repeatability of the methods was good, and the methods are suitable for many foods.

  6. Tomographic scanning apparatus

    International Nuclear Information System (INIS)

    1981-01-01

    This patent specification relates to a tomographic scanning apparatus using a fan beam and digital output signal, and particularly to the design of the gas-pressurized ionization detection system. (U.K.)

  7. Positioning calibration apparatus for transducers employed in nuclear reactor vessel inspection apparatus

    International Nuclear Information System (INIS)

    Elsner, H.J.

    1981-01-01

    The invention provides a calibration apparatus suitable for verifying the position and orientation of transducers used in reactor vessel ultrasonic inspection. The apparatus includes moveable mounting means which secures a transducer within the tank in its normal inspection orientation. A drive is also provided for moving the transducer in the tank relative to a target. The target is slidably positioned in the tank at a distance from the transducer which is selected to avoid the distortion effects in the near field of the transducer. The drive mechanism may be provided with graduated indicia of travel, or a scale may be affixed to the side of the tank. (L.L.)

  8. Analysis of the thermal profiles and the charcoal gravimetric yield in three variations of rectangular brick

    Energy Technology Data Exchange (ETDEWEB)

    Oliveira, Rogerio Lima Mota de; Alves Junior, Edson; Mulina, Bruno Henrique Oliveira; Borges, Valerio Luiz; Carvalho, Solidonio Rodrigues de [Federal University of Uberlandia - UFU, MG (Brazil). School of Mechanical Engineering - FEMEC], e-mails: rogerio@mecanica.ufu.br, edson@mec.ufu.br, vlborges@mecanica.ufu.br, srcarvalho@mecanica.ufu.br

    2010-07-01

    Charcoal assumes a major role in Brazilian economic scenario. The procedure for obtaining charcoal consists in carbonization of wood at certain specific temperatures in kilns. This ancient process has a few joined technologies and the kilns for such practice do not have any control instruments, in their great majority, becoming dependent on the ability of its operators. However, in recent decades several studies have been developed to improve the practice as well as the equipment that involve and control the stages of charcoal production. In this sense, this work proposes the analysis of the thermal profiles and the gravimetric yield in three variations of a rectangular brick kiln called RAC220: traditional (without any type of instrumentation), instrumented with thermal sensors (RTD PT100) and adapted with gasifier. The goal is to correlate temperature, gravimetric yield and quality of the produced charcoal. Immediate analyses were performed to determine the amount of fixed carbon, volatile gases and ashes contents in charcoal. Through such measurement procedures, together with statistical analysis, the aim is to identify an important tool to reduce the time of charcoal production and also contributes to minimize losses and to increase the thermal efficiency of the production process. (author)

  9. Structural features of the southern Tulum Fault System, western central Argentina, through gravimetric data and geomorphologic analyses

    Science.gov (United States)

    Rodríguez, Aixa I.; Christiansen, Rodolfo O.; Suvires, Graciela M.; Lince Klinger, Federico; Martinez, M. Patricia

    2016-12-01

    A gravimetric analysis over the Tulum Valley was made. This data was used to reveal the structural setting of the Tulum Fault System situated in the southeastern part of San Juan province in the arid western part of Argentina. This system is the boundary between two geological provinces, the eastern Precordillera Oriental and the Sierras Pampeanas Occidentales. Gravity data was processed using upward continuation and vertical derivative filters and all the results were compared with the geomorphological and the drainage systems maps of the area. Our assessment confirms the presence of two structures in the Pampeano basement with positive anomalies similar to those found in Valdivia and Barboza hills, two important depocenters with low gravimetric gradients separated by a zone with higher gravity anomalies than the depocenters to the east and west. In view of this, a structural map is proposed for the area. This system is important not only because it is the boundary between two geological provinces and has significance regarding regional tectonic issues but also because it controls the surface drainage, soils distribution and groundwater flow of the Tulum basin conditioning the land use distribution.

  10. Characterization and Gravimetric Analysis of the Dissolved Quartz in the Conversion of Coal Fly Ash to Sodalite

    International Nuclear Information System (INIS)

    Mohd Hilmi Mohamed; Zainab Ramli

    2012-01-01

    Coal fly ash (CFA) is a waste product produced from the electrical power plant and hazardous towards the environment. However, the high composition of silica and alumina in the CFA makes it useful as raw materials in the zeolite synthesis. However, the presence of silica in the form of quartz in the CFA does not facilitate the transformation of CFA to zeolite at 100 degree Celsius and autogeneous pressure. In this study, CFA was converted to zeolites in various NaOH concentrations by microwave heating at various heating time. All synthesized product were characterized by X-ray diffraction (XRD), and gravimetric analysis. XRD has shown that quite pure sodalite in nano size has been formed as early as 15 minutes and increase with time. Prolong heating up to 45 minutes has reduced the content of quartz to ca 20 %. Gravimetric analysis performed on the liquor of the reaction showed that the dissolved silica decrease with increase of heating time indicating that most of the dissolved quartz is used up to form sodalite framework. Hence, quartz of CFA did help in enhancing the crystallinity of the formed sodalite after prolong heating. (author)

  11. Uncertainty associated with the gravimetric measurement of particulate matter concentration in ambient air.

    Science.gov (United States)

    Lacey, Ronald E; Faulkner, William Brock

    2015-07-01

    This work applied a propagation of uncertainty method to typical total suspended particulate (TSP) sampling apparatus in order to estimate the overall measurement uncertainty. The objectives of this study were to estimate the uncertainty for three TSP samplers, develop an uncertainty budget, and determine the sensitivity of the total uncertainty to environmental parameters. The samplers evaluated were the TAMU High Volume TSP Sampler at a nominal volumetric flow rate of 1.42 m3 min(-1) (50 CFM), the TAMU Low Volume TSP Sampler at a nominal volumetric flow rate of 17 L min(-1) (0.6 CFM) and the EPA TSP Sampler at the nominal volumetric flow rates of 1.1 and 1.7 m3 min(-1) (39 and 60 CFM). Under nominal operating conditions the overall measurement uncertainty was found to vary from 6.1x10(-6) g m(-3) to 18.0x10(-6) g m(-3), which represented an uncertainty of 1.7% to 5.2% of the measurement. Analysis of the uncertainty budget determined that three of the instrument parameters contributed significantly to the overall uncertainty: the uncertainty in the pressure drop measurement across the orifice meter during both calibration and testing and the uncertainty of the airflow standard used during calibration of the orifice meter. Five environmental parameters occurring during field measurements were considered for their effect on overall uncertainty: ambient TSP concentration, volumetric airflow rate, ambient temperature, ambient pressure, and ambient relative humidity. Of these, only ambient TSP concentration and volumetric airflow rate were found to have a strong effect on the overall uncertainty. The technique described in this paper can be applied to other measurement systems and is especially useful where there are no methods available to generate these values empirically. This work addresses measurement uncertainty of TSP samplers used in ambient conditions. Estimation of uncertainty in gravimetric measurements is of particular interest, since as ambient particulate

  12. Tomographic scanning apparatus

    International Nuclear Information System (INIS)

    1981-01-01

    Details are presented of a tomographic scanning apparatus, its rotational assembly, and the control and circuit elements, with particular reference to the amplifier and multiplexing circuits enabling detector signal calibration. (U.K.)

  13. Apparatus for washing out halogens

    Energy Technology Data Exchange (ETDEWEB)

    Pier, M; Hahn, J; Kroenig, W

    1941-03-26

    An apparatus is described for washing out of halogens and the like or liquid halogen compounds from the products, which are formed on pressure hydrogenation or splitting of carbon-containing material in the presence of halogens or halogen compounds, consisting of a washing apparatus installed between the reaction vessel and the hot separator, which is inclined in relatively small space for steam regulation and contains, with the steam, arranged baffles, especially spirals.

  14. Isopiestic investigation of the osmotic coefficients of MgBr{sub 2}(aq) and study of bromide salts solubility in the (m{sub 1}KBr + m{sub 2}MgBr{sub 2})(aq) system at T = 323.15 K. Thermodynamic model of solution behaviour and (solid + liquid) equilibria in the MgBr{sub 2}(aq), and (m{sub 1}KBr + m{sub 2}MgBr{sub 2})(aq) systems to high concentration and temperature

    Energy Technology Data Exchange (ETDEWEB)

    Christov, Christomir, E-mail: christov@svr.igic.bas.b [Institute of General and Inorganic Chemistry, Bulgarian Academy of Sciences, ul. ' Acad. G. Bonchev' , bl. 11, 1113 Sofia (Bulgaria)

    2011-03-15

    The isopiestic method has been used to determine the osmotic coefficients of the binary solutions MgBr{sub 2}(aq) (from 0.4950 to 2.5197 mol {center_dot} kg{sup -1}) at the temperature T = 323.15 K. Sodium chloride solutions have been used as isopiestic reference standards. The solubility of the bromide minerals in the mixed system (m{sub 1}KBr + m{sub 2}MgBr{sub 2})(aq) has been investigated at T = 323.15 K by the physico-chemical analysis method. In addition to simple salts {l_brace}KBr(cr) and MgBr{sub 2} . 6H{sub 2}O(cr){r_brace}, equilibrium crystallization of the highly incongruent double salt with stoichiometric composition 1:1:6 {l_brace}bromcarnallite: KBr . MgBr{sub 2} . 6H{sub 2}O(cr){r_brace} was also established. The results obtained from the isopiestic and solubility measurements have been combined with all other experimental thermodynamic quantities available in the literature (osmotic coefficients, and solubility of the bromide mineral) to construct a chemical model that calculates solute and solvent activities and (solid + liquid) equilibria in the MgBr{sub 2}(aq) binary, and (m{sub 1}KBr + m{sub 2}MgBr{sub 2})(aq) mixed systems from dilute to high solution concentration within the (273.15 to 438.15) K temperature range. The solubility modelling approach based on fundamental Pitzer specific interaction equations is employed. It was found, that the standard for 2-1 type of electrolytes approach with three ({beta}{sup (0)}, {beta}{sup (1)}, and C{sup {phi}}) single electrolyte ion interaction parameters gives excellent agreement with osmotic coefficients from T = (298.15 to 373.45) K; up to saturation at 298.15 K, and up to m(MgBr{sub 2}) = 5.83 mol {center_dot} kg{sup -1} at 373.45 K, and with MgBr{sub 2} {center_dot} 6H{sub 2}O(cr) equilibrium pure water solubility data within the (273.15 to 438.15) K temperature range and up to {approx}8.5 mol {center_dot} kg{sup -1} used in parameterization. The model for the ternary system gives very good

  15. Tomographic scanning apparatus

    International Nuclear Information System (INIS)

    1981-01-01

    Details are given of a tomographic scanning apparatus, with particular reference to a multiplexer slip ring means for receiving output from the detectors and enabling interfeed to the image reconstruction station. (U.K.)

  16. Simple, simultaneous gravimetric determination of calcite and dolomite in calcareous soils

    Science.gov (United States)

    Literature pertaining to determination of calcite and dolomite is not modern and describes slow methods that require expensive specialized apparatus. The objective of this paper was to describe a new method that requires no specialized equipment. Linear regressions and correlation coefficients for...

  17. Thermodynamics of {l_brace}zNaCl+(1-z)Na{sub 2}SO{sub 4}{r_brace}(aq) from T=278.15 K to T=318.15 K, and representation with an extended ion-interaction (Pitzer) model

    Energy Technology Data Exchange (ETDEWEB)

    Rard, Joseph A. E-mail: rard1@llnl.gov; Clegg, Simon L.; Platford, Robert

    2003-06-01

    In 1968, R.F. Platford reported the results from extensive isopiestic vapor-pressure measurements for the {l_brace}zNaCl+(1-z)Na{sub 2}SO{sub 4}{r_brace}(aq) system at T=298.15 K, using NaCl(aq) as the isopiestic reference standard [R.F. Platford, J. Chem. Eng. Data 13 (1968) 46-48]. However, only derived quantities were reported, and the experimental isopiestic equilibrium molalities were not given. The complete set of original isopiestic molalities from that study is tabulated in the present report. In addition, published thermodynamic information for this system is reviewed and the isopiestic equilibrium molalities, electromotive force measurements for five different types of electrochemical cells, and enthalpies of mixing from these other studies are critically assessed and recalculated consistently. These combined results are used to evaluate at T=298.15 K the two mixing parameters of Pitzer's ion-interaction model, {sup S}{theta}(Cl,SO{sub 4})=(1.236{+-}0.032{sub 5}){center_dot}10{sup -2} kg{center_dot}mol{sup -1} and {psi}(Na,Cl,SO{sub 4})=(1.808{+-}0.086){center_dot}10{sup -3} kg{sup 2}{center_dot}mol{sup -2}, and their temperature derivatives {l_brace}{partial_derivative}{sup S}{theta}(Cl,SO{sub 4})/{partial_derivative}T{r_brace}{sub p}=(2.474{+-}0.460){center_dot}10{sup -5} kg{center_dot}mol{sup -1}{center_dot}K{sup -1} and {l_brace}{partial_derivative}{psi}(Na,Cl,SO{sub 4})/{partial_derivative}T{r_brace}{sub p}=-(6.228{+-}0.186){center_dot}10{sup -5} kg{sup 2}{center_dot}mol{sup -2}{center_dot}K{sup -1}. Also reported are parameters for an extended ion-interaction model for Na{sub 2}SO{sub 4}(aq), valid from T=(273.15 to 323.15) K, that were required for this mixed electrolyte solution analysis.

  18. Apparatus for filtering radioactive fluids

    International Nuclear Information System (INIS)

    Gischel, E.H.

    1975-01-01

    Apparatus is provided for filtering radioactive particles from the cooling and/or auxiliary process water of a nuclear reactor, or nuclear fuel processing plant, or other installations wherein radioactive fluid systems are known to exist. The apparatus affords disposal of the captured particles in a manner which minimizes the exposure of operating personnel to radioactivity. The apparatus comprises a housing adapted to contain a removable filter cartridge assembly, a valve normally closing the lower end of the housing, an upwardly-open shipping cask located below the valve, and an elongated operating rod assembly projecting upwardly from the filter cartridge assembly and through the upper end of the housing to enable a workman to dismount the filter cartridge assembly from its housing and to lower the filter cartridge assembly through the valve and into the cask from a remote location above the housing. (U.S.)

  19. Process and apparatus for cracking petroleum, etc

    Energy Technology Data Exchange (ETDEWEB)

    1931-04-25

    Process for catalytic cracking of petroleum and similar material at normal pressure, characterized by the oil vaporized in a vaporizer being treated in a first catalyst-chamber and in a separator attached to it, light constituents being separated, and then its being run into a second apparatus-group (vaporizer, catalyst-chamber, and separator), further groups following in series, whereby the catalyst works in a separate catalyst apparatus with ever-increasing activity time on the always lesser but always more difficult to crack material, so that in the whole apparatus a methodical cracking process is effected.

  20. Apparatus for concentrating by dual temperature exchange

    International Nuclear Information System (INIS)

    Spevack, J.S.

    1975-01-01

    Improvements in an apparatus for isotope concentration by dual temperature exchange between feed and auxiliary fluids in a multistage system are described. The first fluid is a vaporizable liquid and the auxiliary fluid a gas, the apparatus having means for cascading the auxiliary fluid and the feed fluid in vapor and preferably also in liquid form. The apparatus also contains new combinations of means for improving the heating and/or cooling and/or humidifying and/or dehumidifying operations of the system. The reactants in the example given are hydrogen sulfide gas and liquid water

  1. Method and apparatus for producing microspherical particles

    International Nuclear Information System (INIS)

    Egli, W.; Bailey, W.H.; Leary, D.F.; Lansley, R.J.

    1979-01-01

    This invention relates generally to a method and apparatus for producing microspherical particles and more particularly to a method and apparatus which are particularly useful in connection with the sol-gel process for the production of nuclear fuel kernels. (U.K.)

  2. Tomographic scanning apparatus

    International Nuclear Information System (INIS)

    1981-01-01

    This patent specification describes a tomographic scanning apparatus, with particular reference to the adjustable fan beam and its collimator system, together with the facility for taking a conventional x-radiograph without moving the patient. (U.K.)

  3. Two-dimensional heat flow apparatus

    Science.gov (United States)

    McDougall, Patrick; Ayars, Eric

    2014-06-01

    We have created an apparatus to quantitatively measure two-dimensional heat flow in a metal plate using a grid of temperature sensors read by a microcontroller. Real-time temperature data are collected from the microcontroller by a computer for comparison with a computational model of the heat equation. The microcontroller-based sensor array allows previously unavailable levels of precision at very low cost, and the combination of measurement and modeling makes for an excellent apparatus for the advanced undergraduate laboratory course.

  4. Optical fiber stripper positioning apparatus

    Science.gov (United States)

    Fyfe, Richard W.; Sanchez, Jr., Amadeo

    1990-01-01

    An optical fiber positioning apparatus for an optical fiber stripping device is disclosed which is capable of providing precise axial alignment between an optical fiber to be stripped of its outer jacket and the cutting blades of a stripping device. The apparatus includes a first bore having a width approximately equal to the diameter of an unstripped optical fiber and a counter bore axially aligned with the first bore and dimensioned to precisely receive a portion of the stripping device in axial alignment with notched cutting blades within the stripping device to thereby axially align the notched cutting blades of the stripping device with the axis of the optical fiber to permit the notched cutting blades to sever the jacket on the optical fiber without damaging the cladding on the optical fiber. In a preferred embodiment, the apparatus further includes a fiber stop which permits determination of the length of jacket to be removed from the optical fiber.

  5. The Conservation Ideological State Apparatus

    Directory of Open Access Journals (Sweden)

    Jared D Margulies

    2018-01-01

    Full Text Available This article considers Louis Althusser's theory of the ideological state apparatuses (ISAs for advancing political ecology scholarship on the functioning of the state in violent environments. I reflect on a series of events in which a state forest department in South India attempted to recast violent conflicts between themselves and local communities over access to natural resources and a protected area as a debate over human-wildlife conflicts. Through the example of conservation as ideology in Wayanad, Kerala, I show how the ISAs articulate the functioning of ideology within the state apparatuses in order for us to understand the larger mechanics of the state apparatus and the reproduction of the relations of production necessary for the reproduction of capitalism. Revisiting the ISAs as a theoretical framework for studies in political ecology and conservation is timely given the resurgence of militarised conservation tactics, the emancipatory aims of Althusser's theory, and political ecology's turn towards praxis.

  6. The Apparatus of Digital Archaeology

    Directory of Open Access Journals (Sweden)

    Jeremy Huggett

    2017-06-01

    Full Text Available Digital Archaeology is predicated upon an ever-changing set of apparatuses – technological, methodological, software, hardware, material, immaterial – which in their own ways and to varying degrees shape the nature of Digital Archaeology. Our attention, however, is perhaps inevitably more closely focused on research questions, choice of data, and the kinds of analyses and outputs. In the process we tend to overlook the effects the tools themselves have on the archaeology we do beyond the immediate consequences of the digital. This article introduces cognitive artefacts as a means of addressing the apparatus more directly within the context of the developing archaeological digital ecosystem. It argues that a critical appreciation of our computational cognitive artefacts is key to understanding their effects on both our own cognition and on the creation of archaeological knowledge. In the process, it defines a form of cognitive digital archaeology in terms of four distinct methods for extracting cognition from the digital apparatus layer by layer.

  7. Scintillation counting apparatus

    International Nuclear Information System (INIS)

    Noakes, J.E.

    1978-01-01

    Apparatus is described for the accurate measurement of radiation by means of scintillation counters and in particular for the liquid scintillation counting of both soft beta radiation and gamma radiation. Full constructional and operating details are given. (UK)

  8. Evaluation of real-time data obtained from gravimetric preparation of antineoplastic agents shows medication errors with possible critical therapeutic impact: Results of a large-scale, multicentre, multinational, retrospective study.

    Science.gov (United States)

    Terkola, R; Czejka, M; Bérubé, J

    2017-08-01

    Medication errors are a significant cause of morbidity and mortality especially with antineoplastic drugs, owing to their narrow therapeutic index. Gravimetric workflow software systems have the potential to reduce volumetric errors during intravenous antineoplastic drug preparation which may occur when verification is reliant on visual inspection. Our aim was to detect medication errors with possible critical therapeutic impact as determined by the rate of prevented medication errors in chemotherapy compounding after implementation of gravimetric measurement. A large-scale, retrospective analysis of data was carried out, related to medication errors identified during preparation of antineoplastic drugs in 10 pharmacy services ("centres") in five European countries following the introduction of an intravenous workflow software gravimetric system. Errors were defined as errors in dose volumes outside tolerance levels, identified during weighing stages of preparation of chemotherapy solutions which would not otherwise have been detected by conventional visual inspection. The gravimetric system detected that 7.89% of the 759 060 doses of antineoplastic drugs prepared at participating centres between July 2011 and October 2015 had error levels outside the accepted tolerance range set by individual centres, and prevented these doses from reaching patients. The proportion of antineoplastic preparations with deviations >10% ranged from 0.49% to 5.04% across sites, with a mean of 2.25%. The proportion of preparations with deviations >20% ranged from 0.21% to 1.27% across sites, with a mean of 0.71%. There was considerable variation in error levels for different antineoplastic agents. Introduction of a gravimetric preparation system for antineoplastic agents detected and prevented dosing errors which would not have been recognized with traditional methods and could have resulted in toxicity or suboptimal therapeutic outcomes for patients undergoing anticancer treatment.

  9. Prehensile apparatus

    Science.gov (United States)

    Smith, C.M.

    1993-10-12

    The present invention relates to an apparatus for handling a workpiece comprising a vessel that is longitudinally extensible and pressurizable, and a nonextensible and laterally flexible member on the vessel. The member constrains one side of the vessel to be nonextensible, causing the vessel to bend in the direction of the nonextensible member when pressurized. 8 figures.

  10. Uncertainty Quantification and Global Sensitivity Analysis of Subsurface Flow Parameters to Gravimetric Variations During Pumping Tests in Unconfined Aquifers

    Science.gov (United States)

    Maina, Fadji Zaouna; Guadagnini, Alberto

    2018-01-01

    We study the contribution of typically uncertain subsurface flow parameters to gravity changes that can be recorded during pumping tests in unconfined aquifers. We do so in the framework of a Global Sensitivity Analysis and quantify the effects of uncertainty of such parameters on the first four statistical moments of the probability distribution of gravimetric variations induced by the operation of the well. System parameters are grouped into two main categories, respectively, governing groundwater flow in the unsaturated and saturated portions of the domain. We ground our work on the three-dimensional analytical model proposed by Mishra and Neuman (2011), which fully takes into account the richness of the physical process taking place across the unsaturated and saturated zones and storage effects in a finite radius pumping well. The relative influence of model parameter uncertainties on drawdown, moisture content, and gravity changes are quantified through (a) the Sobol' indices, derived from a classical decomposition of variance and (b) recently developed indices quantifying the relative contribution of each uncertain model parameter to the (ensemble) mean, skewness, and kurtosis of the model output. Our results document (i) the importance of the effects of the parameters governing the unsaturated flow dynamics on the mean and variance of local drawdown and gravity changes; (ii) the marked sensitivity (as expressed in terms of the statistical moments analyzed) of gravity changes to the employed water retention curve model parameter, specific yield, and storage, and (iii) the influential role of hydraulic conductivity of the unsaturated and saturated zones to the skewness and kurtosis of gravimetric variation distributions. The observed temporal dynamics of the strength of the relative contribution of system parameters to gravimetric variations suggest that gravity data have a clear potential to provide useful information for estimating the key hydraulic

  11. Comparison of Respirable Mass Concentrations Measured by a Personal Dust Monitor and a Personal DataRAM to Gravimetric Measurements.

    Science.gov (United States)

    Halterman, Andrew; Sousan, Sinan; Peters, Thomas M

    2017-12-15

    In 2016, the Mine Safety and Health Administration required the use of continuous monitors to measure respirable dust in mines and better protect miner health. The Personal Dust Monitor, PDM3700, has met stringent performance criteria for this purpose. In a laboratory study, respirable mass concentrations measured with the PDM3700 and a photometer (personal DataRam, pDR-1500) were compared to those measured gravimetrically for five aerosols of varying refractive index and density (diesel exhaust fume, welding fume, coal dust, Arizona road dust (ARD), and salt [NaCl] aerosol) at target concentrations of 0.38, 0.75, and 1.5 mg m-3. For all aerosols except coal dust, strong, near-one-to-one, linear relationships were observed between mass concentrations measured with the PDM3700 and gravimetrically (diesel fume, slope = 0.99, R2 = 0.99; ARD, slope = 0.98, R2 = 0.99; and NaCl, slope = 0.95, R2 = 0.99). The slope deviated substantially from unity for coal dust (slope = 0.55; R2 = 0.99). Linear relationships were also observed between mass concentrations measured with the pDR-1500 and gravimetrically, but one-to-one behavior was not exhibited (diesel fume, slope = 0.23, R2 = 0.76; coal dust, slope = 0.54, R2 = 0.99; ARD, slope = 0.61, R2 = 0.99; NaCl, slope = 1.14, R2 = 0.98). Unlike the pDR-1500, mass concentrations measured with the PDM3700 appear independent of refractive index and density, suggesting that it could have applications in a variety of occupational settings. © The Author(s) 2017. Published by Oxford University Press on behalf of the British Occupational Hygiene Society.

  12. A Simple Apparatus for Fast Ion Exchange Separations

    Energy Technology Data Exchange (ETDEWEB)

    Samsahl, K

    1964-09-15

    An apparatus suitable for very fast ion exchange group separations in radiochemistry has been elaborated. The apparatus which consists of a system of glass tubes with pistons driven by the same force, allows the exact adjustment of influent solutions to a long series of ion-exchange columns. The practical application of the apparatus to the simultaneous separation of six groups of trace elements in the neutron activation analysis of biological material is described.

  13. A Simple Apparatus for Fast Ion Exchange Separations

    International Nuclear Information System (INIS)

    Samsahl, K.

    1964-09-01

    An apparatus suitable for very fast ion exchange group separations in radiochemistry has been elaborated. The apparatus which consists of a system of glass tubes with pistons driven by the same force, allows the exact adjustment of influent solutions to a long series of ion-exchange columns. The practical application of the apparatus to the simultaneous separation of six groups of trace elements in the neutron activation analysis of biological material is described

  14. SCANNING AND TRACKING MONITORING APPARATUS AND METHOD

    DEFF Research Database (Denmark)

    2017-01-01

    Disclosed is a scanning monitoring apparatus for medical imaging, the scanning monitoring apparatus comprising a controller unit and a display, wherein the controller unit during a scanning session is configured to obtain tracking data (102) of a subject in a medical scanner, obtain scanner data ...

  15. Apparatus for blending small particles

    International Nuclear Information System (INIS)

    Bradley, R.A.; Reese, C.R.; Sease, J.D.

    1975-01-01

    An apparatus is described for blending small particles and uniformly loading the blended particles in a receptacle. Measured volumes of various particles are simultaneously fed into a funnel to accomplish radial blending and then directed onto the apex of a conical splitter which collects the blended particles in a multiplicity of equal subvolumes. Thereafter the apparatus sequentially discharges the subvolumes for loading in a receptacle. A system for blending nuclear fuel particles and loading them into fuel rod molds is described in a preferred embodiment

  16. Experimental aspects of buoyancy correction in measuring reliable highpressure excess adsorption isotherms using the gravimetric method.

    Science.gov (United States)

    Nguyen, Huong Giang T; Horn, Jarod C; Thommes, Matthias; van Zee, Roger D; Espinal, Laura

    2017-12-01

    Addressing reproducibility issues in adsorption measurements is critical to accelerating the path to discovery of new industrial adsorbents and to understanding adsorption processes. A National Institute of Standards and Technology Reference Material, RM 8852 (ammonium ZSM-5 zeolite), and two gravimetric instruments with asymmetric two-beam balances were used to measure high-pressure adsorption isotherms. This work demonstrates how common approaches to buoyancy correction, a key factor in obtaining the mass change due to surface excess gas uptake from the apparent mass change, can impact the adsorption isotherm data. Three different approaches to buoyancy correction were investigated and applied to the subcritical CO 2 and supercritical N 2 adsorption isotherms at 293 K. It was observed that measuring a collective volume for all balance components for the buoyancy correction (helium method) introduces an inherent bias in temperature partition when there is a temperature gradient (i.e. analysis temperature is not equal to instrument air bath temperature). We demonstrate that a blank subtraction is effective in mitigating the biases associated with temperature partitioning, instrument calibration, and the determined volumes of the balance components. In general, the manual and subtraction methods allow for better treatment of the temperature gradient during buoyancy correction. From the study, best practices specific to asymmetric two-beam balances and more general recommendations for measuring isotherms far from critical temperatures using gravimetric instruments are offered.

  17. Determination of hydrogen in zirconium hydride and uranium-zirconium hydride by inert gas exraction-gravimetric method

    International Nuclear Information System (INIS)

    Hoshino, Akira; Iso, Shuichi

    1976-01-01

    An inert gas extraction-gravimetric method has been applied to the determination of hydrogen in zirconium hydride and uranium-zirconium hydride which are used as neutron moderator and fuel of nuclear safety research reactor (NSRR), respectively. The sample in a graphite-enclosed quartz crucible is heated inductively to 1200 0 C for 20 min in a helium stream. Hydrogen liberated from the sample is oxidized to water by copper(I) oxide-copper(II) oxide at 400 0 C, and the water is determined gravimetrically by absorption in anhydrone. The extraction curves of hydrogen for zirconium hydride and uranium-zirconium hydride samples are shown in Figs. 2 and 3. Hydrogen in the samples is extracted quantitatively by heating at (1000 -- 1250) 0 C for (10 -- 40) min. Recoveries of hydrogen in the case of zirconium hydride were examined as follows: a weighed zirconium rod (5 phi x 6 mm, hydrogen -5 Torr. After the chamber was filled with purified hydrogen to 200 Torr, the rod was heated to 400 0 C for 15 h, and again weighed to determine the increase in weight. Hydrogen in the rod was then determined by the proposed method. The results are in excellent agreement with the increase in weight as shown in Table 1. Analytical results of hydrogen in zirconium hydride samples and an uranium-zirconium hydride sample are shown in Table 2. (auth.)

  18. Method of magnetic separation and apparatus therefore

    Science.gov (United States)

    Oder, Robin R. (Inventor)

    1991-01-01

    An apparatus for magnetically separating and collecting particulate matter fractions of a raw sample according to relative magnetic susceptibilities of each fraction so collected is disclosed. The separation apparatus includes a splitter which is used in conjunction with a magnetic separator for achieving the desired fractionation.

  19. Comparison between thermo balance and classic gravimetric method for determination of suspended solids in sludge from wastewater treatment plant

    International Nuclear Information System (INIS)

    Bruzzone, E.

    2009-01-01

    In this paper two methods for determination of suspended solids in sludge from wastewater treatment plants (activated, thickened and dry, in a range from 0.1 to 20-25%) are compared. Results are similar from statistic point of view between classic gravimetric method and thermo balance method. However the later seems better for its rapid and easy execution. [it

  20. Analysis of rocks involving the x-ray diffraction, infrared and thermal gravimetric techniques

    International Nuclear Information System (INIS)

    Ikram, M.; Rauf, M.A.; Munir, N.

    1998-01-01

    Chemical analysis of rocks and minerals are usually obtained by a number of analytical techniques. The purpose of present work is to investigate the chemical composition of the rock samples and also to find that how far the results obtained by different instrumental methods are closely related. Chemical tests wee performed before using the instrumental techniques in order to determined the nature of these rocks. The chemical analysis indicated mainly the presence of carbonate and hence the carbonate nature of these rocks. The x-ray diffraction, infrared spectroscopy and thermal gravimetric analysis techniques were used for the determination of chemical composition of these samples. The results obtained by using these techniques have shown a great deal of similarities. (author)

  1. Superconducting magnetic shielding apparatus and method

    Science.gov (United States)

    Clem, John R.; Clem, John R.

    1983-01-01

    Disclosed is a method and apparatus for providing magnetic shielding around a working volume. The apparatus includes a hollow elongated superconducting shell or cylinder having an elongated low magnetic pinning central portion, and two high magnetic pinning end regions. Transition portions of varying magnetic pinning properties are interposed between the central and end portions. The apparatus further includes a solenoid substantially coextensive with and overlying the superconducting cylinder, so as to be magnetically coupled therewith. The method includes the steps passing a longitudinally directed current through the superconducting cylinder so as to depin magnetic reservoirs trapped in the cylinder. Next, a circumferentially directed current is passed through the cylinder, while a longitudinally directed current is maintained. Depinned magnetic reservoirs are moved to the end portions of the cylinder, where they are trapped.

  2. Superconducting magnetic shielding apparatus and method

    Science.gov (United States)

    Clem, J.R.

    1982-07-09

    Disclosed is a method and apparatus for providing magnetic shielding around a working volume. The apparatus includes a hollow elongated superconducting shell or cylinder having an elongated low magnetic pinning central portion, and two high magnetic pinning end regions. Transition portions of varying magnetic pinning properties are interposed between the central and end portions. The apparatus further includes a solenoid substantially coextensive with and overlying the superconducting cylinder, so as to be magnetically coupled therewith. The method includes the steps passing a longitudinally directed current through the superconducting cylinder so as to depin magnetic reservoirs trapped in the cylinder. Next, a circumferentially directed current is passed through the cylinder, while a longitudinally directed current is maintained. Depinned magnetic reservoirs are moved to the end portions of the cylinder, where they are trapped.

  3. Radiation therapy apparatus having retractable beam stopper

    International Nuclear Information System (INIS)

    Coad, G.L.

    1983-01-01

    This invention relates to a radiation therapy apparatus which utilized a linear translation mechanism for positioning a beam stopper. An apparatus is described wherein the beam stopper is pivotally attached to the therapy machine with an associated drive motor in such a way that the beam stopper retracts linearly

  4. Apparatus for separating solids from a liquid

    NARCIS (Netherlands)

    Rem, P.C.; Berkhout, S.P.M.

    2007-01-01

    The invention relates to an apparatus and a method for separating a material stream consisting of several materials. The materials to be separated have different densities or density ranges, so that the material of the highest density can be discharged through a screen of the apparatus, while the

  5. Development and application of PIE apparatuses for high-burnup LWR fuels

    International Nuclear Information System (INIS)

    Harada, Katsuya; Mita, Naoaki; Nishino, Yasuharu; Amano, Hidetoshi

    1999-01-01

    The Reactor Fuel Examination Facility (RFEF) is developing the following post irradiation examination apparatuses: Ion Microprobe mass analyzer (IMA), Pellet Thermal Capacity measuring apparatus (PTC), Micro Density Measuring apparatus MDM, Shield-type Field Emission Scanning Electron Microscope (FE-SEM). The present paper mainly describes several technical topics of these apparatuses. (author)

  6. Apparatus for controlling fluidized beds

    Science.gov (United States)

    Rehmat, A.G.; Patel, J.G.

    1987-05-12

    An apparatus and process are disclosed for control and maintenance of fluidized beds under non-steady state conditions. An ash removal conduit is provided for removing solid particulates from a fluidized bed separate from an ash discharge conduit in the lower portion of the grate supporting such a bed. The apparatus and process of this invention is particularly suitable for use in ash agglomerating fluidized beds and provides control of the fluidized bed before ash agglomeration is initiated and during upset conditions resulting in stable, sinter-free fluidized bed maintenance. 2 figs.

  7. Apparatus and method for radiation processing of materials

    International Nuclear Information System (INIS)

    Neuberg, W.B.; Luniewski, R.

    1983-01-01

    A method and apparatus for radiation degradation processing of polytetrafluoroethylene makes use of a simultaneous irradiation, agitation and cooling. The apparatus is designed to make efficent use of radiation in the processing. (author)

  8. Ion implantation apparatus

    International Nuclear Information System (INIS)

    Forneris, J.L.; Hicks, W.W.; Keller, J.H.; McKenna, C.M.; Siermarco, J.A.; Mueller, W.F.

    1981-01-01

    The invention relates to ion bombardment or implantation apparatus. It comprises an apparatus for bombarding a target with a beam of ions, including an arrangement for measuring the ion beam current and controlling the surface potential of the target. This comprises a Faraday cage formed, at least in part, by the target and by walls adjacent to, and electrically insulated from, the target and surrounding the beam. There is at least one electron source for supplying electrons to the interior of the Faraday cage and means within the cage for blocking direct rectilinear radiation from the source to the target. The target current is measured and combined with the wall currents to provide a measurement of the ion beam current. The quantity of electrons supplied to the interior of the cage can be varied to control the target current and thereby the target surface potential. (U.K.)

  9. Report upon inquiry into radiation apparatus

    International Nuclear Information System (INIS)

    1984-10-01

    In this report the committee has provided its assessment of the need and justification for the law to provide for the control of the provision of radiation apparatus, the planning needs for the provision of diagnostic and therapeutic facilities, the location of such facilities, the appropriateness or otherwise of existing legislation, the necessity for any further legislative needs and the criteria governing the provision of such radiation apparatus

  10. Apparatus and method for gelling liquefied gasses

    Science.gov (United States)

    Elliott, Adam (Inventor); DiSalvo, Roberto (Inventor); Shepherd, Phillip (Inventor); Kosier, Ryan (Inventor)

    2011-01-01

    A method and apparatus for gelling liquid propane and other liquefied gasses includes a temperature controlled churn mixer, vacuum pump, liquefied gas transfer tank, and means for measuring amount of material entering the mixer. The apparatus and method are particularly useful for the production of high quality rocket fuels and propellants.

  11. Apparatus Named after Our Academic Ancestors, III

    Science.gov (United States)

    Greenslade, Thomas B., Jr.

    2014-01-01

    My academic ancestors in physics have called on me once more to tell you about the apparatus that they devised, and that many of you have used in your demonstrations and labs. This article is about apparatus named after François Arago, Heinrich Helmholtz, Leon Foucault, and James Watt.

  12. Experimental determination of absorption-desorption isotherms by computer-controlled gravimetric analysis

    Energy Technology Data Exchange (ETDEWEB)

    Benham, M J; Ross, D K [Birmingham Univ. (UK). School of Physics and Space Research

    1989-01-01

    We describe the operating principles of an automated microbalance apparatus designed to give superior reproducibility over extended operating cycles and to derive asymptotic values from the time dependence of mass uptake. The performance achieved is illustrated using measurements of exaggerated buoyancy, and P-C-T data from the Pd-H system. (orig.).

  13. Apparatuses, Systems and Methods for Cleaning Photovoltaic Devices

    KAUST Repository

    Eitelhuber, Georg

    2013-01-01

    Embodiments of solar panel cleaning apparatuses, solar panel cleaning systems, and solar panel cleaning methods are disclosed. In certain embodiments, the disclosed solar panel cleaning apparatuses, systems and methods do may not require any water

  14. Nano-TiCl4/SiO2: an efficient heterogeneous solid acid catalyst for ...

    Indian Academy of Sciences (India)

    Mirjalili

    OMEGA transmission electron microscopy, respectively. The thermal gravimetric analysis. (TGA) was done with “NETZSCH TG 209 F1 Iris” instrument. Melting points were obtained with a Yanagimoto micro melting point apparatus. The purity determination of the substrates and reactions monitoring were accomplished by ...

  15. Metering apparatus and tariffs for electricity supply

    International Nuclear Information System (INIS)

    1990-01-01

    Conference papers presented cover system economies and tariff structure with papers on pricing of electricity and new metering technologies. Other topics reviewed include metering apparatus design, electronic metering apparatus and solid phase metering technology. Meter data retrieval, bulk supply metering, test equipment and maintenance, and legal requirements and standards are discussed. (author)

  16. Apparatus bias and place conditioning with ethanol in mice.

    Science.gov (United States)

    Cunningham, Christopher L; Ferree, Nikole K; Howard, MacKenzie A

    2003-12-01

    Although the distinction between "biased" and "unbiased" is generally recognized as an important methodological issue in place conditioning, previous studies have not adequately addressed the distinction between a biased/unbiased apparatus and a biased/unbiased stimulus assignment procedure. Moreover, a review of the recent literature indicates that many reports (70% of 76 papers published in 2001) fail to provide adequate information about apparatus bias. This issue is important because the mechanisms underlying a drug's effect in the place-conditioning procedure may differ depending on whether the apparatus is biased or unbiased. The present studies were designed to assess the impact of apparatus bias and stimulus assignment procedure on ethanol-induced place conditioning in mice (DBA/2 J). A secondary goal was to compare various dependent variables commonly used to index conditioned place preference. Apparatus bias was manipulated by varying the combination of tactile (floor) cues available during preference tests. Experiment 1 used an unbiased apparatus in which the stimulus alternatives were equally preferred during a pre-test as indicated by the group average. Experiment 2 used a biased apparatus in which one of the stimuli was strongly preferred by most mice (mean % time on cue = 67%) during the pre-test. In both studies, the stimulus paired with drug (CS+) was assigned randomly (i.e., an "unbiased" stimulus assignment procedure). Experimental mice received four pairings of CS+ with ethanol (2 g/kg, i.p.) and four pairings of the alternative stimulus (CS-) with saline; control mice received saline on both types of trial. Each experiment concluded with a 60-min choice test. With the unbiased apparatus (experiment 1), significant place conditioning was obtained regardless of whether drug was paired with the subject's initially preferred or non-preferred stimulus. However, with the biased apparatus (experiment 2), place conditioning was apparent only when

  17. Apparatus for carbonization of bituminous materials

    Energy Technology Data Exchange (ETDEWEB)

    Krupa, G

    1924-08-25

    Apparatus is described for carbonization of bituminous fuels and bituminous shale, in which the material to be carbonized slips continuously over sloping surfaces of a retort arranged in a zigzag and thereby it is exposed to a continuously increasing heating. The apparatus is characterized by the sloping surface being of a boxlike solid hearth with internal heating through which every hearth can be heated directly to a determined constant degree of heat.

  18. Centrifuge apparatus

    Science.gov (United States)

    Sartory, Walter K.; Eveleigh, John W.

    1976-01-01

    A method and apparatus for operating a continuous flow blood separation centrifuge are provided. The hematocrit of the entrant whole blood is continuously maintained at an optimum constant value by the addition of plasma to the entrant blood. The hematocrit of the separated red cells is monitored to indicate the degree of separation taking place, thereby providing a basis for regulating the flow through the centrifuge.

  19. Capillary Condensation of Binary and Ternary Mixtures of n-Pentane-Isopentane-CO2 in Nanopores: An Experimental Study on the Effects of Composition and Equilibrium.

    Science.gov (United States)

    Barsotti, Elizabeth; Saraji, Soheil; Tan, Sugata P; Piri, Mohammad

    2018-02-06

    Confinement in nanopores can significantly impact the chemical and physical behavior of fluids. While some quantitative understanding is available for how pure fluids behave in nanopores, there is little such insight for mixtures. This study aims to shed light on how nanoporosity impacts the phase behavior and composition of confined mixtures through comparison of the effects of static and dynamic equilibrium on experimentally measured isotherms and chromatographic analysis of the experimental fluids. To this end, a novel gravimetric apparatus is introduced and validated. Unlike apparatuses that have been previously used to study the confinement-induced phase behavior of fluids, this apparatus employs a gravimetric technique capable of discerning phase transitions in a wide variety of nanoporous media under both static and dynamic conditions. The apparatus was successfully validated against data in the literature for pure carbon dioxide and n-pentane. Then, isotherms were generated for binary mixtures of carbon dioxide and n-pentane using static and flow-through methods. Finally, two ternary mixtures of carbon dioxide, n-pentane, and isopentane were measured using the static method. While the equilibrium time was found important for determination of confined phase transitions, flow rate in the dynamic method was not found to affect the confined phase behavior. For all measurements, the results indicate qualitative transferability of the bulk phase behavior to the confined fluid.

  20. Pin-on-disk apparatus for tribological studies of polymeric materials

    DEFF Research Database (Denmark)

    Ølholm Larsen, Thomas; Løgstrup Andersen, Tom; Thorning, Bent

    2009-01-01

    polymeric materials under dry-sliding conditions. The different main parts of the apparatus are described in a way which partly explains the choice of construction and partly makes it possible to produce a similar apparatus. Furthermore, a limited amount of tribological data is presented mainly to exemplify......The purpose of this paper is to describe the construction of a custom-built pin-on-disk (POD) apparatus based on a simple design and on important guidelines. The POD apparatus is built as a part of the main author's PhD project. The apparatus is built at a low cost and is suited for testing...... weave. The data presented in this paper are limited since the main objective is to describe the construction of a POD apparatus. The paper is intended to be a source of inspiration for industrial or academic laboratories who want to establish their own tailor-suited tribological test-equipment, instead...

  1. Apparatuses, Systems and Methods for Cleaning Photovoltaic Devices

    KAUST Repository

    Eitelhuber, Georg

    2013-02-14

    Embodiments of solar panel cleaning apparatuses, solar panel cleaning systems, and solar panel cleaning methods are disclosed. In certain embodiments, the disclosed solar panel cleaning apparatuses, systems and methods do may not require any water or other cleaning liquids in the whole cleaning process, which makes them prominent well suited in for water-deficit environments such as deserts. In one embodiment, the solar panel cleaning apparatus comprises one or more rotatable brushes each having a rotational axis and a drive configured to move each of the one or more rotatable brushes in a direction that is not perpendicular to the rotational axis. The solar panel cleaning apparatus is may be configured such that the angle of the rotational axis of at least one of the one or more rotatable brushes is adjustable relative to the direction of travel.

  2. Thermal Acoustic Fatigue Apparatus

    Data.gov (United States)

    Federal Laboratory Consortium — The Thermal Acoustic Fatigue Apparatus (TAFA) is a progressive wave tube test facility that is used to test structures for dynamic response and sonic fatigue due to...

  3. Fuel pellet loading apparatus

    International Nuclear Information System (INIS)

    1980-01-01

    Apparatus is described for loading a predetermined amount of nuclear fuel pellets into nuclear fuel elements and particularly for the automatic loading of fuel pellets from within a sealed compartment. (author)

  4. Radiographic scanner apparatus

    International Nuclear Information System (INIS)

    Wake, R.H.

    1980-01-01

    The preferred embodiment of this invention includes a hardware system, or processing means, which operates faster than software. Moreover the computer needed is less expensive and smaller. Radiographic scanner apparatus is described for measuring the intensity of radiation after passage through a planar region and for reconstructing a representation of the attenuation of radiation by the medium. There is a source which can be rotated, and detectors, the output from which forms a data line. The detectors are disposed opposite the planar region from the source to produce a succession of data lines corresponding to the succession of angular orientations of the source. There is a convolver means for convolving each of these data lines, with a filter function, and a means of processing the convolved data lines to create the representation of the radiation attenuation in the planar region. There is also apparatus to generate a succession of data lines indicating radiation attenuation along a determinable path with convolver means. (U.K.)

  5. Fuel exchanging apparatus

    International Nuclear Information System (INIS)

    Imada, Takahiko; Sato, Hideo.

    1975-01-01

    Object: To provide a centripetal device, which has an initial spring force greater than a frictional force in an oscillating direction of a telescope mast, on a mast fixing device mounted on a body of fuel exchanging apparatus so that the telescope mast may be secured quickly returning to a predetermined initial position. Structure: When the body of fuel exchanging apparatus is stopped at a predetermined position, a tension spring, which has an initial spring force greater than a frictional force in an oscillating direction of the telescope mast, causes a lug to be forced by means of a push rod to position a sliding base plate to its original position. At the same time, a device of similar structure causes an operating arm to be positioned to the original position, and a lock pin urged by a cylinder is inserted into a through hole in the sliding base plate and operating arm so that the telescope mast may be fixed and retained. (Hanada, M.)

  6. Estimation of generation and gravimetric composition of solid wastes at Federal University of Campina Grande, Pombal, Paraíba, Brazil

    Directory of Open Access Journals (Sweden)

    Elisângela Maria da Silva

    2018-01-01

    Full Text Available The objective was to present the estimation of the per capita generation and gravimetric composition of the solid residues of the Center of Sciences and Agri-food technology of the Federal University of Campina Grande. These two characteristics are of fundamental importance in the solid waste management process. The methodological procedure was carried out by field survey to identify the number of sectors in the University Campus, as well as the quantification of the daily population that attends the institution. As a result, the daily per capita generation of the Science Center and Environmental Technology was 49.28 g. In relation to the gravimetric composition, it was verified that the organic matter had the highest percentage, representing a total of 66%, followed by 13% of plastics, 9% of paper / cardboard and 8% of composites. It is concluded that the largest part of the total solid waste generated is putrescible organic matter, which was already expected, since solid waste generated in the university campus presents characteristics of household waste.

  7. Model of Coupled Drives Apparatus – Static and Dynamic Characteristics

    Directory of Open Access Journals (Sweden)

    Chalupa Petr

    2016-01-01

    Full Text Available The paper presents an initial part of a modelling the Coupled Drives Apparatus CE108 developed by TecQuipment Ltd. The final model should be used in the process of control design for the apparatus. The model derived by the developers of the apparatus using first-principle modelling is used as a starting point for comparison of its properties with measured characteristics. The static and dynamic characteristics of the real-time apparatus are presented and discussed. Special attention is paid to principal differences between the model and the real-time apparatus. Real-time measurements are obtained using MATLAB / Simulink environment in connection with a Real-time Toolbox. Evaluation of the experiments is also performed in the MATLAB environment

  8. Device for discharging drain in a control rod driving apparatus

    International Nuclear Information System (INIS)

    Ikeda, Tadasu; Ikuta, Takuzo; Yoshida, Tomiji; Tsukahara, Katsumi.

    1975-01-01

    Object: To efficiently and safely collect and discharge drain by a simple construction in which a drain cover and a drain tank in a control rod driving apparatus are integrally formed, and an overhauling wrench of said apparatus and a drain hose are mounted on the drain tank. Structure: When a mounting bolt is untightened by a torque wrench so as to be removed from a flange surface of the control rod driving apparatus in a nuclear reactor, axial movement of said apparatus is absorbed by a spring so that drain containing a radioactive material is discharged into a drain tank through the flange surface of said apparatus and is then guided into a collecting tank through a drain hose. (Kamimura, M.)

  9. Testing of defects in Si semiconductor apparatus by using single-photon detection

    International Nuclear Information System (INIS)

    Zhongliang, Pan; Ling, Chen; Guangju, Chen

    2013-01-01

    The failure analysis of semiconductor apparatus is very needed for ensuring product quality, which can find several types of defects in the semiconductor apparatus. A new testing method for the defects in Si semiconductor apparatus is presented in this paper, the method makes use of photon emissions to find out the failure positions or failure components by taking advantage of the infrared photo emission characteristics of semiconductor apparatus. These emitted photons carry the information of the apparatus structure. If there are defects in the apparatus, these photons can help in understanding the apparatus properties and detecting the defects. An algorithm for the generation of circuit input vectors are presented in this paper to enhance the strength of the emitted photons for the given components in the semiconductor apparatus. The multiple-valued logic, the static timing analysis and path sensitizations, are used in the algorithm. A lot of experimental results for the Si semiconductor apparatus show that many types of defects such as contact spiking and latchup failure etc., can be detected accurately by the method proposed in this paper

  10. Method and apparatus for dismantling mechanical anchors

    Energy Technology Data Exchange (ETDEWEB)

    Dubovskiy, Yu P; Chendev, F S; Gritsayuk, B I; Gubin, N I; Osipov, S P

    1982-01-01

    This apparatus is designed to reduce the amount of labor required to dismantle mechanical anchors while at the same time lowering expenditures for lumber. Longwall beams and timber skips are used to support the cap and any fractured rock faces. The apparatus itself has grooves, vertical guides, and a drive system to position the longwall beams.

  11. Apparatus For Eddy-Current Inspection Of Bolts

    Science.gov (United States)

    Amos, Jay M.

    1994-01-01

    Eddy-current apparatus for inspection of bolts, studs, and other threaded fasteners detects flaws in threads, shanks, and head fillets. With help of apparatus, technician quickly inspects fasteners of various dimensions. Accommodates fasteners with diameters from 0.190 in. to 1 in. and with lengths up to 5 in. Basic design modified to accommodate fasteners of other sizes.

  12. Applicability of two automated disintegration apparatuses for rapidly disintegrating (mini)tablets.

    Science.gov (United States)

    Sieber, Daniel; Lazzari, Alessia; Quodbach, Julian; Pein, Miriam

    2017-03-01

    Orally disintegrating (mini)tablets (OD(M)Ts) are of interest in the field of pharmaceutics. Their orodispersible character is defined by the disintegration time, which is measured with a basket apparatus according to the European Pharmacopoeia. This method, however, lacks applicability for ODTs and especially ODMTs. New disintegration apparatuses have been described in literature, but a qualification to assess the applicability has not been described. A qualification procedure for two automated disintegration apparatuses, OD-mate and Hermes apparatus, is introduced. Aspects of the operational qualification as well as precision and accuracy regarding a performance qualification were evaluated for both apparatuses analog to the ICH guideline Q2. While the OQ study is performed separately for each apparatus, accuracy and precision were performed following the same protocol for both testers. Small RSDs (16.9% OD-mate; 15.2% Hermes compared to 32.3% for the pharmacopeial method) were found despite very fast disintegration times (1.5 s for both apparatuses). By comparing these RSDs to practical examples, the authors propose threshold values for repeatability depending on the mean disintegration time. Obtained results from the qualification were used to assess the applicability of both apparatuses.

  13. A prototype splitter apparatus for dividing large catches of small fish

    Science.gov (United States)

    Stapanian, Martin A.; Edwards, William H.

    2012-01-01

    Due to financial and time constraints, it is often necessary in fisheries studies to divide large samples of fish and estimate total catch from the subsample. The subsampling procedure may involve potential human biases or may be difficult to perform in rough conditions. We present a prototype gravity-fed splitter apparatus for dividing large samples of small fish (30–100 mm TL). The apparatus features a tapered hopper with a sliding and removable shutter. The apparatus provides a comparatively stable platform for objectively obtaining subsamples, and it can be modified to accommodate different sizes of fish and different sample volumes. The apparatus is easy to build, inexpensive, and convenient to use in the field. To illustrate the performance of the apparatus, we divided three samples (total N = 2,000 fish) composed of four fish species. Our results indicated no significant bias in estimating either the number or proportion of each species from the subsample. Use of this apparatus or a similar apparatus can help to standardize subsampling procedures in large surveys of fish. The apparatus could be used for other applications that require dividing a large amount of material into one or more smaller subsamples.

  14. Providing long-term trend and gravimetric factor at Chandler period from superconducting gravimeter records by using Singular Spectrum Analysis along with its multivariate extension

    Science.gov (United States)

    Gruszczynska, M.; Rosat, S.; Klos, A.; Bogusz, J.

    2017-12-01

    In this study, Singular Spectrum Analysis (SSA) along with its multivariate extension MSSA (Multichannel SSA) were used to estimate long-term trend and gravimetric factor at the Chandler wobble frequency from superconducting gravimeter (SG) records. We have used data from seven stations located worldwide and contributing to the International Geodynamics and Earth Tides Service (IGETS). The timespan ranged from 15 to 19 years. Before applying SSA and MSSA, we had removed local tides, atmospheric (ECMWF data), hydrological (MERRA2 products) loadings and non-tidal ocean loading (ECCO2 products) effects. In the first part of analysis, we used the SSA approach in order to estimate the long-term trends from SG observations. We use the technique based on the classical Karhunen-Loève spectral decomposition of time series into long-term trend, oscillations and noise. In the second part, we present the determination of common time-varying pole tide (annual and Chandler wobble) to estimate gravimetric factor from SG time series using the MSSA approach. The presented method takes advantage over traditional methods like Least Squares Estimation by determining common modes of variability which reflect common geophysical field. We adopted a 6-year lag-window as the optimal length to extract common seasonal signals and the Chandler components of the Earth polar motion. The signals characterized by annual and Chandler wobble account for approximately 62% of the total variance of residual SG data. Then, we estimated the amplitude factors and phase lags of Chandler wobble with respect to the IERS (International Earth Rotation and Reference Systems Service) polar motion observations. The resulting gravimetric factors at the Chandler Wobble period are finally compared with previously estimates. A robust estimate of the gravimetric Earth response to the Chandlerian component of the polar motion is required to better constrain the mantle anelasticity at this frequency and hence the

  15. Measurement of Gd content in (U,Gd)O2 using thermal gravimetric analysis

    International Nuclear Information System (INIS)

    Kim, Keon Sik; Yang, Jae Ho; Kang, Ki Won; Song, Kun Woo; Kim, Gil Moo

    2004-01-01

    We propose a simple and precise method for measuring the Gd content in the (U,Gd)O 2 pellet by only measuring the weight variation of the pellet during thermal heat treatment in air. The (U,Gd)O 2 fuel pellets were oxidized at 475 deg. C, subsequently heat treated at 1300 deg. C, and then cooled to room temperature in air. The accompanying weight variations were measured using thermo gravimetric analysis (TGA). The measured weight variations were mathematically analyzed with reference to the successive phase reactions during the heat treatment. This method provides an advantage in that the rare-earth element content including Gd can be measured using relatively simple equipment such as an electric furnace and a balance

  16. Tomographic scanning apparatus

    International Nuclear Information System (INIS)

    1981-01-01

    Details are given of a tomographic scanning apparatus, with particular reference to the means of adjusting the apparent gain of the signal processing means for receiving output signals from the detectors, to compensate for drift in the gain characteristics, including means for passing a reference signal. (U.K.)

  17. The first Australian gravimetric quasigeoid model with location-specific uncertainty estimates

    Science.gov (United States)

    Featherstone, W. E.; McCubbine, J. C.; Brown, N. J.; Claessens, S. J.; Filmer, M. S.; Kirby, J. F.

    2018-02-01

    We describe the computation of the first Australian quasigeoid model to include error estimates as a function of location that have been propagated from uncertainties in the EGM2008 global model, land and altimeter-derived gravity anomalies and terrain corrections. The model has been extended to include Australia's offshore territories and maritime boundaries using newer datasets comprising an additional {˜ }280,000 land gravity observations, a newer altimeter-derived marine gravity anomaly grid, and terrain corrections at 1^' ' }× 1^' ' } resolution. The error propagation uses a remove-restore approach, where the EGM2008 quasigeoid and gravity anomaly error grids are augmented by errors propagated through a modified Stokes integral from the errors in the altimeter gravity anomalies, land gravity observations and terrain corrections. The gravimetric quasigeoid errors (one sigma) are 50-60 mm across most of the Australian landmass, increasing to {˜ }100 mm in regions of steep horizontal gravity gradients or the mountains, and are commensurate with external estimates.

  18. Gravimetric Viral Diagnostics: QCM Based Biosensors for Early Detection of Viruses

    Directory of Open Access Journals (Sweden)

    Adeel Afzal

    2017-02-01

    Full Text Available Viruses are pathogenic microorganisms that can inhabit and replicate in human bodies causing a number of widespread infectious diseases such as influenza, gastroenteritis, hepatitis, meningitis, pneumonia, acquired immune deficiency syndrome (AIDS etc. A majority of these viral diseases are contagious and can spread from infected to healthy human beings. The most important step in the treatment of these contagious diseases and to prevent their unwanted spread is to timely detect the disease-causing viruses. Gravimetric viral diagnostics based on quartz crystal microbalance (QCM transducers and natural or synthetic receptors are miniaturized sensing platforms that can selectively recognize and quantify harmful virus species. Herein, a review of the label-free QCM virus sensors for clinical diagnostics and point of care (POC applications is presented with major emphasis on the nature and performance of different receptors ranging from the natural or synthetic antibodies to selective macromolecular materials such as DNA and aptamers. A performance comparison of different receptors is provided and their limitations are discussed.

  19. CASTING APPARATUS

    Science.gov (United States)

    Gray, C.F.; Thompson, R.H.

    1958-09-23

    An apparatus is described for casting small quantities of uranlum. It consists of a crucible having a hole in the bottom with a mold positioned below. A vertical rcd passes through the hole in the crucible and has at its upper end a piercing head adapted to break the oxide skin encasing a molten uranium body. An air tight cylinder surrounds the crucible and mold, and is arranged to be evacuated.

  20. Thermal analysis of thermo-gravimetric measurements of spent nuclear fuel oxidation rates

    International Nuclear Information System (INIS)

    Cramer, E.R.

    1997-01-01

    A detailed thermal analysis was completed of the sample temperatures in the Thermo-Gravimetric Analysis (TGA) system used to measure irradiated N Reactor fuel oxidation rates. Sample temperatures during the oxidation process did not show the increase which was postulated as a result of the exothermic reactions. The analysis shows the axial conduction of heat in the sample holder effectively removes the added heat and only a very small, i.e., <10 C, increase in temperature is calculated. A room temperature evaporation test with water showed the sample thermocouple sensitivity to be more than adequate to account for a temperature change of approximately 5 C. Therefore, measured temperatures in the TGA are within approximately 10 C of the actual sample temperatures and no adjustments to reported data to account for the heat input from the oxidation process are necessary

  1. Experimental aspects of buoyancy correction in measuring reliable high-pressure excess adsorption isotherms using the gravimetric method

    Science.gov (United States)

    Nguyen, Huong Giang T.; Horn, Jarod C.; Thommes, Matthias; van Zee, Roger D.; Espinal, Laura

    2017-12-01

    Addressing reproducibility issues in adsorption measurements is critical to accelerating the path to discovery of new industrial adsorbents and to understanding adsorption processes. A National Institute of Standards and Technology Reference Material, RM 8852 (ammonium ZSM-5 zeolite), and two gravimetric instruments with asymmetric two-beam balances were used to measure high-pressure adsorption isotherms. This work demonstrates how common approaches to buoyancy correction, a key factor in obtaining the mass change due to surface excess gas uptake from the apparent mass change, can impact the adsorption isotherm data. Three different approaches to buoyancy correction were investigated and applied to the subcritical CO2 and supercritical N2 adsorption isotherms at 293 K. It was observed that measuring a collective volume for all balance components for the buoyancy correction (helium method) introduces an inherent bias in temperature partition when there is a temperature gradient (i.e. analysis temperature is not equal to instrument air bath temperature). We demonstrate that a blank subtraction is effective in mitigating the biases associated with temperature partitioning, instrument calibration, and the determined volumes of the balance components. In general, the manual and subtraction methods allow for better treatment of the temperature gradient during buoyancy correction. From the study, best practices specific to asymmetric two-beam balances and more general recommendations for measuring isotherms far from critical temperatures using gravimetric instruments are offered.

  2. Hydrologically induced orientation variations of a tri-axial Earth's principal axes based on satellite-gravimetric and hydrological models

    Directory of Open Access Journals (Sweden)

    Shen Wenbin

    2013-05-01

    Full Text Available The Earth is a tri-axial body, with unequal principal inertia moments, A, B and C. The corresponding principal axes a, b and c are determined by the mass distribution of the Earth, and their orientations vary with the mass redistribution. In this study, the hydrologically induced variations are estimated on the basis of satellite gravimetric data, including those from satellite laser ranging (SLR and gravity recovery and climate experiment (GRACE, and hydrological models from global land data assimilation system (GLDAS. The longitude variations of a and b are mainly related to the variations of the spherical harmonic coefficients C¯22 and S¯22, which have been estimated to be consisting annual variations of about 1. 6 arc seconds and 1. 8 arc seconds, respectively, from gravity data. This result is confirmed by land surface water storage provided by the GLDAS model. If the atmospheric and oceanic signals are removed from the spherical harmonic coefficients C¯21 and S¯21, the agreement of the orientation series for c becomes poor, possibly due to the inaccurate background models used in pre-processing of the satellite gravimetric data. Determination of the orientation variations may provide a better understanding of various phenomena in the study of the rotation of a tri-axial Earth.

  3. APPARATUS FOR THE PRODUCTION OF LITHIUM METAL

    Science.gov (United States)

    Baker, P.S.; Duncan, F.R.; Greene, H.B.

    1961-08-22

    Methods and apparatus for the production of high-purity lithium from lithium halides are described. The apparatus is provided for continuously contacting a molten lithium halide with molten barium, thereby forming lithium metal and a barium halide, establishing separate layers of these reaction products and unreacted barium and lithium halide, and continuously withdrawing lithium and barium halide from the reaction zone. (AEC)

  4. Apparatus to simulate nuclear heating in advanced fuels

    International Nuclear Information System (INIS)

    Wrona, B.J.; Galvin, T.M.; Johanson, E.

    1976-10-01

    A direct-electrical-heating apparatus has been built to simulate in-reactor temperature gradients and heating conditions in both the mixed nitrides and carbides of uranium and plutonium. The apparatus has the capability for the investigation and direct observation of fuel-behavior phenomena that should significantly enlarge the data base on mixed carbides and nitrides at temperatures near and above their melting points. In addition to heating UC, results of prooftests showed that the apparatus has the capability to heat graphite, 30 vol % ZrC in graphite, B 4 C control-rod pellets, and stainless steel

  5. Apparatus for the measurement of density-thickness by use of radiation

    International Nuclear Information System (INIS)

    Buchnea, A.

    1983-01-01

    The invention is used in on-line apparatus for continuously monitoring a property of a moving length of materials in which a source of radiation and a detector are mounted in spaced relationship at an on-line location at which the moving length is permitted to pass between the source and the detector. The invention involves an apparatus for calibrating the monitoring apparatus without moving the monitoring apparatus from the on-line location

  6. Apparatus for control of mercury

    Science.gov (United States)

    Downs, William; Bailey, Ralph T.

    2001-01-01

    A method and apparatus for reducing mercury in industrial gases such as the flue gas produced by the combustion of fossil fuels such as coal adds hydrogen sulfide to the flue gas in or just before a scrubber of the industrial process which contains the wet scrubber. The method and apparatus of the present invention is applicable to installations employing either wet or dry scrubber flue gas desulfurization systems. The present invention uses kraft green liquor as a source for hydrogen sulfide and/or the injection of mineral acids into the green liquor to release vaporous hydrogen sulfide in order to form mercury sulfide solids.

  7. Uranium dioxide calcining apparatus and method

    International Nuclear Information System (INIS)

    Cole, E.A.; Peterson, R.S.

    1978-01-01

    This invention relates to an improved continuous calcining apparatus for consistently and controllably producing from calcinable reactive solid compounds of uranium, such as ammonium diuranate, uranium dioxide (UO 2 ) having an oxygen to uranium ratio of less than 2.2. The apparatus comprises means at the outlet end of a calciner kiln for receiving hot UO 2 , means for cooling the UO 2 to a temperature of below 100 0 C and conveying the cooled UO 2 to storage or to subsequent UO 2 processing apparatus where it finally comes into contact with air, the means for receiving, cooling and conveying being sealed to the outlet end of the calciner and being maintained full of UO 2 and so operable as to exclude atmospheric oxygen from coming into contact with any UO 2 which is at elevated temperatures where it would readily oxidize, without the use of extra hydrogen gas in said means

  8. Building scientific apparatus

    National Research Council Canada - National Science Library

    Moore, John H; Davis, Christopher C; Coplan, Michael A; Greer, Sandra C

    2009-01-01

    ... specification of the components of apparatus, many new to this edition. Data on the properties of materials and components used by manufacturers are included. Mechanical, optical, and electronic construction techniques carried out in the laboratory, as well as those let out to specialized shops, are also described. Step-by-step instruc...

  9. Modified swelling pressure apparatus using vapor pressure technique for compacted bentonite

    International Nuclear Information System (INIS)

    Nishimura, Tomoyoshi

    2012-01-01

    Document available in extended abstract form only. bentonite. The compacted bentonite is found in unsaturated conditions before applying of swelling due to absorption. The behaviour of compacted bentonite is not consistent with the principle and concepts of classical, saturated soil mechanics. An unsaturated soil theoretical framework using soil water characteristic curve has been fairly established over the past several decades. The soil-water characteristic curve is a relationship between soil moisture and soil suction obtained by the axis translation technique, vapor pressure technique or osmotic suction control which is a key feature in unsaturated soil mechanics. The soil-water characteristic curve can be used for prediction of the shear strength, volume change and hydraulic conductivity. Cui et al. 2002 indicated soil-water characteristic curve of expansive clay soil in high soil suction ranges using osmotic suction technique. Tripathy et al. 2010 described the soil-water characteristic curve both using the axis translation technique and vapor pressure technique in the entire soil suction ranges. Nishimura and Koseki 2011 measured suction of bentonite applied high soil suction due vapor pressure using a chilled mirror dew point potentiometer (WP4-T of DECAGON Device). The bentonite with gravimetric water content of 18 % indicated soil suction of 2.8 MPa at least. It is predicted that suction efforts to swelling pressure and shear strength of unsaturated compacted bentonite. This study focuses on the influence of suction on both swelling pressure and shear strength of compacted bentonite. The soil-water characteristic curve (SWCC) tests were conducted for compacted bentonite using both axis-translation technique and vapor pressure technique. The SWCC had a range from 0 kPa to 296 MPa in suction. The compacted bentonite having two different soil suctions were prepared for swelling pressure tests. Newly swelling pressure testing apparatus was developed in order

  10. Superconducting magnetic energy storage apparatus structural support system

    Science.gov (United States)

    Withers, Gregory J.; Meier, Stephen W.; Walter, Robert J.; Child, Michael D.; DeGraaf, Douglas W.

    1992-01-01

    A superconducting magnetic energy storage apparatus comprising a cylindrical superconducting coil; a cylindrical coil containment vessel enclosing the coil and adapted to hold a liquid, such as liquefied helium; and a cylindrical vacuum vessel enclosing the coil containment vessel and located in a restraining structure having inner and outer circumferential walls and a floor; the apparatus being provided with horizontal compression members between (1) the coil and the coil containment vessel and (2) between the coil containment vessel and the vacuum vessel, compression bearing members between the vacuum vessel and the restraining structure inner and outer walls, vertical support members (1) between the coil bottom and the coil containment vessel bottom and (2) between the coil containment vessel bottom and the vacuum vessel bottom, and external supports between the vacuum vessel bottom and the restraining structure floor, whereby the loads developed by thermal and magnetic energy changes in the apparatus can be accommodated and the structural integrity of the apparatus be maintained.

  11. Pulsed wire discharge apparatus for mass production of copper nanopowders.

    Science.gov (United States)

    Suematsu, H; Nishimura, S; Murai, K; Hayashi, Y; Suzuki, T; Nakayama, T; Jiang, W; Yamazaki, A; Seki, K; Niihara, K

    2007-05-01

    A pulsed wire discharge (PWD) apparatus for the mass production of nanopowders has been developed. The apparatus has a continuous wire feeder, which is operated in synchronization with a discharging circuit. The apparatus is designed for operation at a maximum repetition rate of 1.4 Hz at a stored energy of 160 J. In the present study, Cu nanopowder was synthesized using the PWD apparatus and the performance of the apparatus was examined. Cu nanopowder of 2.0 g quantity was prepared in N(2) gas at 100 kPa for 90 s. The particle size distribution of the Cu nanopowder was analyzed by transmission electron microscopy and the mean surface diameter was determined to be 65 nm. The ratio of the production mass of the powder to input energy was 362 g/kW h.

  12. An extraordinary tabletop speed of light apparatus

    Science.gov (United States)

    Pegna, Guido

    2017-09-01

    A compact, low-cost, pre-aligned apparatus of the modulation type is described. The apparatus allows accurate determination of the speed of light in free propagation with an accuracy on the order of one part in 104. Due to the 433.92 MHz radio frequency (rf) modulation of its laser diode, determination of the speed of light is possible within a sub-meter measuring base and in small volumes (some cm3) of transparent solids or liquids. No oscilloscope is necessary, while the required function generators, power supplies, and optical components are incorporated into the design of the apparatus and its receiver can slide along the optical bench while maintaining alignment with the laser beam. Measurement of the velocity factor of coaxial cables is also easily performed. The apparatus detects the phase difference between the rf modulation of the laser diode by further modulating the rf signal with an audio frequency signal; the phase difference between these signals is then observed as the loudness of the audio signal. In this way, the positions at which the minima of the audio signal are found determine where the rf signals are completely out of phase. This phase detection method yields a much increased sensitivity with respect to the display of coincidence of two signals of questionable arrival time and somewhat distorted shape on an oscilloscope. The displaying technique is also particularly suitable for large audiences as well as in unattended exhibits in museums and science centers. In addition, the apparatus can be set up in less than one minute.

  13. Apparatus, System, And Method For Roadway Monitoring

    KAUST Repository

    Claudel, Christian G.

    2015-06-02

    An apparatus, system, and method for monitoring traffic and roadway water conditions. Traffic flow and roadway flooding is monitored concurrently through a wireless sensor network. The apparatus and system comprises ultrasound rangefinders monitoring traffic flow, flood water conditions, or both. Routing information may be calculated from the traffic conditions, such that routes are calculated to avoid roadways that are impassable or are slow due to traffic conditions.

  14. Apparatus, System, And Method For Roadway Monitoring

    KAUST Repository

    Claudel, Christian G.

    2015-01-01

    An apparatus, system, and method for monitoring traffic and roadway water conditions. Traffic flow and roadway flooding is monitored concurrently through a wireless sensor network. The apparatus and system comprises ultrasound rangefinders monitoring traffic flow, flood water conditions, or both. Routing information may be calculated from the traffic conditions, such that routes are calculated to avoid roadways that are impassable or are slow due to traffic conditions.

  15. Synergistic improvement of gas sensing performance by micro-gravimetrically extracted kinetic/thermodynamic parameters

    International Nuclear Information System (INIS)

    Guo, Shuanbao; Xu, Pengcheng; Yu, Haitao; Cheng, Zhenxing; Li, Xinxin

    2015-01-01

    Highlights: • Sensing material can be comprehensively optimized by using gravimetric cantilever. • Kinetic-thermodynamic model parameters are quantitatively extracted by experiment • Sensing-material performance is synergistically optimized by extracted parameters. - Abstract: A novel method is explored for comprehensive design/optimization of organophosphorus sensing material, which is loaded on mass-type microcantilever sensor. Conventionally, by directly observing the gas sensing response, it is difficult to build quantitative relationship with the intrinsic structure of the material. To break through this difficulty, resonant cantilever is employed as gravimetric tool to implement molecule adsorption experiment. Based on the sensing data, key kinetic/thermodynamic parameters of the material to the molecule, including adsorption heat −ΔH°, adsorption/desorption rate constants K a and K d , active-site number per unit mass N′ and surface coverage θ, can be quantitatively extracted according to physical–chemistry theories. With gaseous DMMP (simulant of organophosphorus agents) as sensing target, the optimization route for three sensing materials is successfully demonstrated. Firstly, a hyper-branched polymer is evaluated. Though suffering low sensitivity due to insufficient N′, the bis(4-hydroxyphenyl)-hexafluoropropane (BHPF) sensing-group exhibits satisfactory reproducibility due to appropriate −ΔH°. To achieve more sensing-sites, KIT-5 mesoporous-silica with higher surface-area is assessed, resulting in good sensitivity but too high −ΔH° that brings poor repeatability. After comprehensive consideration, the confirmed BHPF sensing-group is grafted on the KIT-5 carrier to form an optimized DMMP sensing nanomaterial. Experimental results indicate that, featuring appropriate kinetic/thermodynamic parameters of −ΔH°, K a , K d , N′ and θ, the BHPF-functionalized KIT-5 mesoporous silica exhibits synergistic improvement among

  16. Grinding assembly, grinding apparatus, weld joint defect repair system, and methods

    Science.gov (United States)

    Larsen, Eric D.; Watkins, Arthur D.; Bitsoi, Rodney J.; Pace, David P.

    2005-09-27

    A grinding assembly for grinding a weld joint of a workpiece includes a grinder apparatus, a grinder apparatus includes a grinding wheel configured to grind the weld joint, a member configured to receive the grinding wheel, the member being configured to be removably attached to the grinder apparatus, and a sensor assembly configured to detect a contact between the grinding wheel and the workpiece. The grinding assembly also includes a processing circuitry in communication with the grinder apparatus and configured to control operations of the grinder apparatus, the processing circuitry configured to receive weld defect information of the weld joint from an inspection assembly to create a contour grinding profile to grind the weld joint in a predetermined shape based on the received weld defect information, and a manipulator having an end configured to carry the grinder apparatus, the manipulator further configured to operate in multiple dimensions.

  17. System, methods and apparatus for program optimization for multi-threaded processor architectures

    Science.gov (United States)

    Bastoul, Cedric; Lethin, Richard A; Leung, Allen K; Meister, Benoit J; Szilagyi, Peter; Vasilache, Nicolas T; Wohlford, David E

    2015-01-06

    Methods, apparatus and computer software product for source code optimization are provided. In an exemplary embodiment, a first custom computing apparatus is used to optimize the execution of source code on a second computing apparatus. In this embodiment, the first custom computing apparatus contains a memory, a storage medium and at least one processor with at least one multi-stage execution unit. The second computing apparatus contains at least two multi-stage execution units that allow for parallel execution of tasks. The first custom computing apparatus optimizes the code for parallelism, locality of operations and contiguity of memory accesses on the second computing apparatus. This Abstract is provided for the sole purpose of complying with the Abstract requirement rules. This Abstract is submitted with the explicit understanding that it will not be used to interpret or to limit the scope or the meaning of the claims.

  18. Article separation apparatus and method for unit operations

    Science.gov (United States)

    Pardini, Allan F.; Gervais, Kevin L.; Mathews, Royce A.; Hockey, Ronald L.

    2010-06-22

    An apparatus and method are disclosed for separating articles from a group of articles. The apparatus includes a container for containing one or more articles coupled to a suitable fluidizer for suspending articles within the container and transporting articles to an induction tube. A portal in the induction tube introduces articles singly into the induction tube. A vacuum pulls articles through the induction tube separating the articles from the group of articles in the container. The apparatus and method can be combined with one or more unit operations or modules, e.g., for inspecting articles, assessing quality of articles, or ascertaining material properties and/or parameters of articles, including layers thereof.

  19. Phase change thermal control materials, method and apparatus

    Science.gov (United States)

    Buckley, Theresa M. (Inventor)

    2001-01-01

    An apparatus and method for metabolic cooling and insulation of a user in a cold environment. In its preferred embodiment the apparatus is a highly flexible composite material having a flexible matrix containing a phase change thermal storage material. The apparatus can be made to heat or cool the body or to act as a thermal buffer to protect the wearer from changing environmental conditions. The apparatus may also include an external thermal insulation layer and/or an internal thermal control layer to regulate the rate of heat exchange between the composite and the skin of the wearer. Other embodiments of the apparatus also provide 1) a path for evaporation or direct absorption of perspiration from the skin of the wearer for improved comfort and thermal control, 2) heat conductive pathways within the material for thermal equalization, 3) surface treatments for improved absorption or rejection of heat by the material, and 4) means for quickly regenerating the thermal storage capacity for reuse of the material. Applications of the composite materials are also described which take advantage of the composite's thermal characteristics. The examples described include a diver's wet suit, ski boot liners, thermal socks, gloves and a face mask for cold weather activities, and a metabolic heating or cooling blanket useful for treating hypothermia or fever patients in a medical setting and therapeutic heating or cooling orthopedic joint supports.

  20. Continuously rotating cat scanning apparatus and method

    International Nuclear Information System (INIS)

    Bax, R.F.

    1980-01-01

    A tomographic scanner with a continuously rotating source of radiation is energized by converting inertial mechanical energy to electrical energy. The mechanical-to-electrical conversion apparatus is mounted with the x-ray source to be energized on a rotating flywheel. The inertial mechanical energy stored in the rotating conversion apparatus, flywheel and x-ray source is utilized for generating electrical energy used, in turn, to energize the x-ray source

  1. Apparatus for controlling nuclear core debris

    Science.gov (United States)

    Jones, Robert D.

    1978-01-01

    Nuclear reactor apparatus for containing, cooling, and dispersing reactor debris assumed to flow from the core area in the unlikely event of an accident causing core meltdown. The apparatus includes a plurality of horizontally disposed vertically spaced plates, having depressions to contain debris in controlled amounts, and a plurality of holes therein which provide natural circulation cooling and a path for debris to continue flowing downward to the plate beneath. The uppermost plates may also include generally vertical sections which form annular-like flow areas which assist the natural circulation cooling.

  2. Apparatus for controlling nuclear core debris

    International Nuclear Information System (INIS)

    Jones, R.D.

    1978-01-01

    Disclosed is an apparatus for containing, cooling, and dispersing reactor debris assumed to flow from the core area in the unlikely event of an accident causing core meltdown. The apparatus includes a plurality of horizontally disposed vertically spaced plates, having depressions to contain debris in controlled amounts, and a plurality of holes therein which provide natural circulation cooling and a path for debris to continue flowing downward to the plate beneath. The uppermost plates may also include generally vertical sections which form annular-like flow areas which assist the natural circulation cooling

  3. Programmers for diagnostic x-ray apparatus

    International Nuclear Information System (INIS)

    1981-01-01

    Novel apparatus is described for providing a pre-programmed selection of various parameters in X-ray radiography. The equipment consists of push-buttons which prompt the radiographer to make decisions such as thickness of patient, part of the anatomy to be X-rayed etc. From these data the apparatus selects the appropriate parameters such as H.T. voltage, current, product of current and irradiation time etc. The values of these parameters are displayed to the radiographer and facilities are provided to override the programmed parameters at the radiographer's discretion. (U.K.)

  4. Modeling and Inversion of three-dimensional crustal structures beneath the Pyrenees and their foreland basins based upon geological, gravimetric and seismological data

    Science.gov (United States)

    Spangenberg, Hannah; Chevrot, Sébastien; Courrioux, Gabriel; Guillen, Antonio

    2017-04-01

    Our goal is to obtain a three-dimensional (3D) model of mass density and seismic velocities beneath the Pyrenees and their foreland basins (Aquitaine and Ebro basins), which accounts for all the geological and geophysical information available for that region. This model covers the whole mountain range going from the Atlantic Ocean to the Mediterranean Sea, and from the Iberian range to the Massif Central. The model is described by different units: the lower, middle, and upper crusts, the accretionary prism, and the consolidated and unconsolidated sediment layers. Furthermore, a sub-continental, serpentinized European mantle is introduced to describe the exhumed mantle bodies which are responsible for the positive Bouguer gravity anomalies in the western Pyrenees. We build a first 3D model using all the geological information: drill-hole surveys, seismic sections, and the geological map. We use the potential field method implemented in Geomodeler to interpolate these geological data. However, these data are too sparse to build a model that explains seismic travel times or gravimetric data, especially the Labourd and the St. Gaudens Bouguer gravity anomalies. In addition, inconsistencies between the different data sets exist. We thus add by trial and error additional data points, comparing modeled and observed Bouguer gravimetric anomalies. The result of this procedure is a 3D geological model that respects the geological data and explains the measured Bouguer gravimetric anomalies. In a second step, we use this model to determine the average density and seismic velocities inside each geological unit assuming uniform layers. To constrain the seismic velocities we use travel time picks extracted from the bulletin of the Pyrenean seismicity released by the Observatoire Midi Pyrenées. In a third step, we use this 3D a priori model in a Monte Carlo inversion to invert jointly gravimetric data and seismic travel times from the bulletin. This probabilistic approach

  5. Radiography apparatus

    International Nuclear Information System (INIS)

    Redmayne, I.G.B.

    1985-01-01

    Apparatus for the inspection of pipe welds comprises a radiation source for transmitting radiation, say as X-rays, through a pipe weld and a detector in a box arranged diametrically opposite the source, with respect to the pipe, for detecting the transmitted radiation and providing electrical signals which are processed to produce an image of the weld. The source and detector are mounted on a frame which is rotatable about an inner frame clamped to the pipe. (author)

  6. Imaging Apparatus And Method

    NARCIS (Netherlands)

    Manohar, Srirang; van Leeuwen, A.G.J.M.

    2010-01-01

    A thermoacoustic imaging apparatus comprises an electromagnetic radiation source configured to irradiate a sample area and an acoustic signal detection probe arrangement for detecting acoustic signals. A radiation responsive acoustic signal generator is added outside the sample area. The detection

  7. IMAGING APPARATUS AND METHOD

    NARCIS (Netherlands)

    Manohar, Srirang; van Leeuwen, A.G.J.M.

    2008-01-01

    A thermoacoustic imaging apparatus comprises an electromagnetic radiation source configured to irradiate a sample area and an acoustic signal detection probe arrangement for detecting acoustic signals. A radiation responsive acoustic signal generator is added outside the sample area. The detection

  8. Nuclear fuel pellet loading apparatus

    International Nuclear Information System (INIS)

    Gerkey, K.S.

    1979-01-01

    An automatic apparatus for loading a predetermined amount of nuclear fuel pellets into a nuclear fuel element to be used in a nuclear reactor is described. The apparatus consists of a vibratory bed capable of supporting corrugated trays containing rows of nuclear fuel pellets and arranged in alignment with the open ends of several nuclear fuel elements. A sweep mechanism is arranged above the trays and serves to sweep the rows of fuel pellets onto the vibratory bed and into the fuel element. A length detecting system, in conjunction with a pellet stopping mechanism, is also provided to assure that a predetermined amount of nuclear fuel pellets are loaded into each fuel element

  9. Validation of phenol red versus gravimetric method for water reabsorption correction and study of gender differences in Doluisio's absorption technique.

    Science.gov (United States)

    Tuğcu-Demiröz, Fatmanur; Gonzalez-Alvarez, Isabel; Gonzalez-Alvarez, Marta; Bermejo, Marival

    2014-10-01

    The aim of the present study was to develop a method for water flux reabsorption measurement in Doluisio's Perfusion Technique based on the use of phenol red as a non-absorbable marker and to validate it by comparison with gravimetric procedure. The compounds selected for the study were metoprolol, atenolol, cimetidine and cefadroxil in order to include low, intermediate and high permeability drugs absorbed by passive diffusion and by carrier mediated mechanism. The intestinal permeabilities (Peff) of the drugs were obtained in male and female Wistar rats and calculated using both methods of water flux correction. The absorption rate coefficients of all the assayed compounds did not show statistically significant differences between male and female rats consequently all the individual values were combined to compare between reabsorption methods. The absorption rate coefficients and permeability values did not show statistically significant differences between the two strategies of concentration correction. The apparent zero order water absorption coefficients were also similar in both correction procedures. In conclusion gravimetric and phenol red method for water reabsorption correction are accurate and interchangeable for permeability estimation in closed loop perfusion method. Copyright © 2014 Elsevier B.V. All rights reserved.

  10. Development of apparatus for surveying uranium surface contamination quantity

    International Nuclear Information System (INIS)

    Wang Qingheng; Han Jingquan

    1994-11-01

    An apparatus for measuring uranium contamination of the surface of reactor plate component is described. The searching unit of the apparatus is a large surface multi-wire proportional counter. The cathode of the counter is made of stainless steel with low radioactive background, the window is made of film which is plated with aluminum about 6 μm; and the anode is mad by gild tungsten wire of 0.025 mm diameter. The sensitive area of the counter is 1113 mm x 100 mm. It has been shown that the intrinsic radioactive background of the apparatus is 0.002 cpm/cm 2 (2 count/min). The detecting efficiency is 67% for enriched uranium source (2π solid angle). The stability is 0.84% within 24 hour (including detector, high voltage power supply, amplifier, discriminator, computer, type and display system). The lower detection limit of the apparatus is 4.6 x 10 -10 g/cm 2 (for 20% 235 U, 0.13% 234 U, 79.64% 238 U). The apparatus can present timing by a computer controlling, and it also has the following functions: displaying, automatic alarming, classifying and typing the results. (2 tabs., 7 figs.)

  11. Apparatus and process for passivating an SRF cavity

    Science.gov (United States)

    Myneni, Ganapati Rao; Wallace, John P

    2014-12-02

    An apparatus and process for the production of a niobium cavity exhibiting high quality factors at high gradients is provided. The apparatus comprises a first chamber positioned within a second chamber, an RF generator and vacuum pumping systems. The process comprises placing the niobium cavity in a first chamber of the apparatus; thermally treating the cavity by high temperature in the first chamber while maintaining high vacuum in the first and second chambers; and applying a passivating thin film layer to a surface of the cavity in the presence of a gaseous mixture and an RF field. Further a niobium cavity exhibiting high quality factors at high gradients produced by the method of the invention is provided.

  12. Li4FeH6: Iron-containing complex hydride with high gravimetric hydrogen density

    Directory of Open Access Journals (Sweden)

    Hiroyuki Saitoh

    2014-07-01

    Full Text Available Li4FeH6, which has the highest gravimetric hydrogen density of iron-containing complex hydrides reported so far, is synthesized by hydrogenation of a powder mixture of iron and LiH above 6.1 GPa at 900 °C. In situ synchrotron radiation X-ray diffraction measurements reveal that while kinetics require high temperature and thus high pressure for the synthesis, Li4FeH6 is expected to be thermodynamically stable slightly below room temperature at ambient pressure; further synthetic studies to suppress the kinetic effects may enable us to synthesize Li4FeH6 at moderate pressures. Li4FeH6 can be recovered at ambient conditions where Li4FeH6 is metastable.

  13. Pressure suppression apparatus of a nuclear power plant

    International Nuclear Information System (INIS)

    Mizumachi, W.; Funalashi, T.

    1980-01-01

    Pressure suppression apparatus for a nuclear reactor comprises a vessel surrounding a reactor pressure vessel and containing a water pool at the bottom of the vessel, and a steam exhaust pipe. The apparatus further comprises an exhaust chamber connected to the immersed portion of the exhaust pipe and provided with a number of discharge openings. (auth)

  14. Mobile lighting apparatus

    Science.gov (United States)

    Roe, George Michael; Klebanoff, Leonard Elliott; Rea, Gerald W; Drake, Robert A; Johnson, Terry A; Wingert, Steven John; Damberger, Thomas A; Skradski, Thomas J; Radley, Christopher James; Oros, James M; Schuttinger, Paul G; Grupp, David J; Prey, Stephen Carl

    2013-05-14

    A mobile lighting apparatus includes a portable frame such as a moveable trailer or skid having a light tower thereon. The light tower is moveable from a stowed position to a deployed position. A hydrogen-powered fuel cell is located on the portable frame to provide electrical power to an array of the energy efficient lights located on the light tower.

  15. 46 CFR 160.010-5 - Buoyant apparatus with plastic foam buoyancy.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 6 2010-10-01 2010-10-01 false Buoyant apparatus with plastic foam buoyancy. 160.010-5... Vessels § 160.010-5 Buoyant apparatus with plastic foam buoyancy. (a) Buoyant apparatus with plastic foam buoyancy must have a plastic foam body with an external protective covering. The body may be reinforced as...

  16. Past and present of measuring apparatus for nuclear medicine

    International Nuclear Information System (INIS)

    Murayama, Hideo

    2013-01-01

    The history of advancement of measuring apparatus for nuclear medicine is looked back. It is presented that Japanese contribution to these advancement has been in no small quantities. The future view carrying the measuring apparatus for nuclear medicine is also described. (M.H.)

  17. 46 CFR 160.010-6 - Capacity of buoyant apparatus.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 6 2010-10-01 2010-10-01 false Capacity of buoyant apparatus. 160.010-6 Section 160.010-6 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) EQUIPMENT, CONSTRUCTION, AND... apparatus is not considered in determining the capacity. (b) [Reserved] ...

  18. Apparatus for handling control rod drives

    International Nuclear Information System (INIS)

    Akimoto, A.; Watanabe, M.; Yoshida, T.; Sugaya, Z.; Saito, T.; Ishii, Y.

    1979-01-01

    An apparatus for handling control rod drives (CRD's) attached by detachable fixing means to housings mounted in a reactor pressure vessel and each coupled to one of control rods inserted in the reactor pressure vessel is described. The apparatus for handling the CRD's comprise cylindrical housing means, uncoupling means mounted in the housing means for uncoupling each of the control rods from the respective CRD, means mounted on the housing means for effecting attaching and detaching of the fixing means, means for supporting the housing means, and means for moving the support means longitudinally of the CRD

  19. Resonant gravimetric immunosensing based on capacitive micromachined ultrasound transducers

    KAUST Repository

    Viržonis, Darius

    2014-04-08

    High-frequency (40 MHz) and low-frequency (7 MHz) capacitive micromachined ultrasound transducers (CMUT) were fabricated and tested for use in gravimetric detection of biomolecules. The low-frequency CMUT sensors have a gold-coated surface, while the high-frequency sensors have a silicon nitride surface. Both surfaces were functionalized with bovine leukemia virus antigen gp51 acting as the antigen. On addition of an a specific antibody labeled with horseradish peroxidase (HRP), the antigen/antibody complex is formed on the surface and quantified by HRP-catalyzed oxidation of tetramethylbenzidine. It has been found that a considerably smaller quantity of immuno complex is formed on the high frequency sensor surface. In parallel, the loading of the surface of the CMUT was determined via resonance frequency and electromechanical resistance readings. Following the formation of the immuno complexes, the resonance frequencies of the low-frequency and high-frequency sensors decrease by up to 420 and 440 kHz, respectively. Finite element analysis reveals that the loading of the (gold-coated) low frequency sensors is several times larger than that on high frequency sensors. The formation of the protein film with pronounced elasticity and stress on the gold surface case is discussed. We also discuss the adoption of this method for the detection of DNA using a hybridization assay following polymerase chain reaction.

  20. Proton imaging apparatus for proton therapy application

    International Nuclear Information System (INIS)

    Sipala, V.; Lo Presti, D.; Brianzi, M.; Civinini, C.; Bruzzi, M.; Scaringella, M.; Talamonti, C.; Bucciolini, M.; Cirrone, G.A.P.; Cuttone, G.; Randazzo, N.; Stancampiano, C.; Tesi, M.

    2011-01-01

    Radiotherapy with protons, due to the physical properties of these particles, offers several advantages for cancer therapy as compared to the traditional radiotherapy and photons. In the clinical use of proton beams, a p CT (Proton Computer Tomography) apparatus can contribute to improve the accuracy of the patient positioning and dose distribution calculation. In this paper a p CT apparatus built by the Prima (Proton Imaging) Italian Collaboration will be presented and the preliminary results will be discussed.

  1. THE APPARATUS FOR ALIGNMENT OF THE PHOTOMETRIC LAMP FILAMENT

    Directory of Open Access Journals (Sweden)

    V. A. Dlugunovich

    2015-01-01

    Full Text Available During photometric measurements involving the use of photometric lamps it is necessary that the filament of lamp takes a strictly predetermined position with respect to the photodetector and the optical axis of the photometric setup. The errors in positioning of alignment filament with respect to the optical axis of the measuring system lead to increase the uncertainty of measurement of the photometric characteristics of the light sources. A typical method for alignment of filament of photometric lamps is based on the use a diopter tubes (telescopes. Using this method, the mounting of filament to the required position is carried out by successive approximations, which requires special concentration and a lot of time. The aim of this work is to develop an apparatus for alignment which allows simultaneous alignment of the filament of lamps in two mutually perpendicular planes. The method and apparatus for alignment of the photometric lamp filament during measurements of the photometric characteristics of light sources based on two digital video cameras is described in this paper. The apparatus allows to simultaneously displaying the image of lamps filament on the computer screen in two mutually perpendicular planes. The apparatus eliminates a large number of functional units requiring elementwise alignment and reduces the time required to carry out the alignment. The apparatus also provides the imaging of lamps filament with opaque coated on the bulb. The apparatus is used at the National standard of light intensity and illuminance units of the Republic of Belarus. 

  2. The use of gravimetric data from GRACE mission in the understanding of polar motion variations

    Science.gov (United States)

    Seoane, L.; Nastula, J.; Bizouard, C.; Gambis, D.

    2009-08-01

    Tesseral coefficients C21 and S21 derived from Gravity Recovery and Climate Experiment (GRACE) observations allow to compute the mass term of the polar-motion excitation function. This independent estimation can improve the geophysical models and, in addition, determine the unmodelled phenomena. In this paper, we intend to validate the polar motion excitation derived from GRACE's last release (GRACE Release 4) computed by different institutes: GeoForschungsZentrum (GFZ), Postdam, Germany; Center for Space Research (CSR), Austin, USA; Jet Propulsion Laboratory (JPL), Pasadena, USA, and the Groupe de Recherche en Géodésie Spatiale (GRGS), Toulouse, France. For this purpose, we compare these excitations functions first to the mass term obtained from observed Earth's rotation variations free of the motion term and, second, to the mass term estimated from geophysical fluids models. We confirm the large improvement of the CSR solution, and we show that the GRGS estimate is also well correlated with the geodetic observations. Significant discrepancies exist between the solutions of each centre. The source of these differences is probably related to the data processing strategy. We also consider residuals computed after removing the geophysical models or the gravimetric solutions from the geodetic mass term. We show that the residual excitation based on models is smoother than the gravimetric data, which are still noisy. Still, they are comparable for the χ2 component. It appears that χ2 residual signals using GFZ and JPL data have less variability. Finally, for assessing the impact of the geophysical fluids models choice on our results, we checked two different oceanic excitation series. We show the significant differences in the residuals correlations, especially for the χ1 more sensitive to the oceanic signals.

  3. A comparison of daily water use estimates derived from constant-heat sap-flow probe values and gravimetric measurements in pot-grown saplings.

    Science.gov (United States)

    K.A. McCulloh; K. Winter; F.C. Meinzer; M. Garcia; J. Aranda; Lachenbruch B.

    2007-01-01

    The use of Granier-style heat dissipation sensors to measure sap flow is common in plant physiology, ecology, and hydrology. There has been concern that any change to the original Granier design invalidates the empirical relationship between sap flux density and the temperature difference between the probes. We compared daily water use estimates from gravimetric...

  4. Apparatus for the ammonium recovery from liquid animal manure

    NARCIS (Netherlands)

    Starmans, D.A.J.; Timmerman, M.

    2013-01-01

    Nitrogen present in animal manure can be a limiting factor when considering manure application rates onto arable land. EU-regulations triggered the development of a new ammonia exchange apparatus for the recovery of ammonia. The described apparatus has a liquid to liquid ammonia mass transfer

  5. 49 CFR 234.211 - Security of warning system apparatus.

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 4 2010-10-01 2010-10-01 false Security of warning system apparatus. 234.211... ADMINISTRATION, DEPARTMENT OF TRANSPORTATION GRADE CROSSING SIGNAL SYSTEM SAFETY AND STATE ACTION PLANS Maintenance, Inspection, and Testing Maintenance Standards § 234.211 Security of warning system apparatus...

  6. Apparatus and method for the electrolysis of water

    Science.gov (United States)

    Greenbaum, Elias

    2015-04-21

    An apparatus for the electrolytic splitting of water into hydrogen and/or oxygen, the apparatus comprising: (i) at least one lithographically-patternable substrate having a surface; (ii) a plurality of microscaled catalytic electrodes embedded in said surface; (iii) at least one counter electrode in proximity to but not on said surface; (iv) means for collecting evolved hydrogen and/or oxygen gas; (v) electrical powering means for applying a voltage across said plurality of microscaled catalytic electrodes and said at least one counter electrode; and (vi) a container for holding an aqueous electrolyte and housing said plurality of microscaled catalytic electrodes and said at least one counter electrode. Electrolytic processes using the above electrolytic apparatus or functional mimics thereof are also described.

  7. X-ray examination apparatus

    International Nuclear Information System (INIS)

    Bernstein, S.; Griswa, P.J.; Halter, P. Jr.; Kidd, H.J.

    1980-01-01

    Apparatus for x-ray cardiovascular examination and which can also be used for general purpose examination is described. An advantage of the system is that there is no mechanical connection between the image intensifier and source to interfere with the medical examiner or emergency procedures. (U.K.)

  8. Portable apparatus for measurement of nuclear radiation

    International Nuclear Information System (INIS)

    Whitlock, G.D.

    1975-01-01

    The apparatus described is stated to be particularly applicable to the measurement of tritium contamination of a surface, although it may have other applications to the determination of radioactivity on surfaces. The mean range of a tritium β particle in air at normal atmospheric pressure is only 1.5 mm. and when monitoring such radiation with the apparatus it is necessary to exclude light. The apparatus comprises a plastic scintillator sheet located in the base of a housing, with a sealing ring mounted in the base so as to make a hermetic and light-tight seal between a support surface and the base of the housing. Photomultiplier means are optically coupled to the scintillator sheet to detect and amplify the scintillations, and a pump device is provided to reduce the air pressure in the vicinity of the sheet to below atmospheric pressure. The scintillator sheet and the photomultiplier means are movable as one unit within the housing, the unit being arranged to be acted upon by atmospheric pressure so as to move the unit into an operative position against a spring when the air pressure in the vicinity of the sheet is reduced to below atmospheric pressure. A shutter is provided to prevent exposure of the scintillator sheet to light when the apparatus is not in use. (U.K.)

  9. Nuclear magnetic resonance apparatus

    International Nuclear Information System (INIS)

    Lambert, R.

    1991-01-01

    In order to include the effect of a magnetic object in a subject under investigation, Nuclear Magnetic Resonance (NMR) apparatus is operable at more than one radio frequency (RF) frequency. The apparatus allows normal practice as far as obtaining an NMR response or image from a given nuclear species is concerned, but, in addition, interrogates the nuclear spin system at a frequency which is different from the resonance frequency normally used for the given nuclear species, as determined from the applied magnetic field. The magnetic field close to a magnetised or magnetisable object is modified and the given nuclear species gives a response at the different frequency. Thus detection of a signal at the frequency indicates the presence of the chosen nuclei close to the magnetised or magnetisable object. Applications include validation of an object detection or automatic shape inspection system in the presence of magnetic impurities, and the detection of magnetic particles which affect measurement of liquid flow in a pipe. (author)

  10. Apparatus for gamma radiography

    International Nuclear Information System (INIS)

    1983-06-01

    The aim of the present standard is to fix the rules for the construction of gamma radiography instrumentation without prejudice to the present regulations. These apparatus have to be fitted with only sealed sources conformable to the experimental standard M 61-002. The present standard agrees with the international standard ISO 3999 of 1977 dealing with the same subject. Nevertheless, it is different on the three main following points: it does not accept the same limits of absorbed dose rates in the air calculated on the external surface of projectors; it precribes tightness, bending, crushing and tensile tests for some components of the gamma radiography it prescribes tests of endurance and resistance to breaking for the locking systems of the gamma radiography apparatus. The present standard also specifies the following points: symbols and indications to put on projectors and on the source-holder; identification of the source contained in the projector; and, accompanying documents. The regulation references are given in annexe [fr

  11. Improvements in measuring apparatus

    International Nuclear Information System (INIS)

    Casey, W.

    1976-01-01

    Measuring apparatus is described that is suitable for gauging the wall profiles of downwardly extending channels in nuclear reactors, but which is equally applicable to channels such as pipe bores and conduits in other types of plant. The apparatus comprises a probe carrying a measuring transducer giving an electrical output. The probe support may be moved stepwise along the channel along a track between end members. An electrical conductor is provided for transmitting the electrical output of the transducer to an indicator located remote from the probe. The probe support may consist of a cable attached at one end to a winding drum, and incorporating an electrical conductor connected to the transducer. Channel engaging means are provided on the probe that permits free upward movement of the probe when the latter is suspended by the cable and moves into gripping engagement with the channel wall when the tension in the cable is relaxed. (U.K.)

  12. A multifunctional microwave plasma reaction apparatus and its applications

    International Nuclear Information System (INIS)

    Wang Xizhang; Wu Qiang; Hu Zheng; Xu Hua; Miao Shui; Chen Yi

    2000-01-01

    A multifunctional apparatus for microwave plasma reaction has been set up, which can be used in the fields such as chemical synthesis, surface modification, and heterogeneous catalysis. The apparatus has laid an experimental foundation for new methods, new technologies, and new train of thoughts to be explored

  13. 21 CFR 862.2485 - Electrophoresis apparatus for clinical use.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Electrophoresis apparatus for clinical use. 862.2485 Section 862.2485 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN... Instruments § 862.2485 Electrophoresis apparatus for clinical use. (a) Identification. An electrophoresis...

  14. 7 CFR 801.9 - Tolerances for test weight apparatuses.

    Science.gov (United States)

    2010-01-01

    ... 7 Agriculture 7 2010-01-01 2010-01-01 false Tolerances for test weight apparatuses. 801.9 Section 801.9 Agriculture Regulations of the Department of Agriculture (Continued) GRAIN INSPECTION, PACKERS... PERFORMANCE REQUIREMENTS FOR GRAIN INSPECTION EQUIPMENT § 801.9 Tolerances for test weight apparatuses. The...

  15. Apparatus for making molten silicon

    Science.gov (United States)

    Levin, Harry (Inventor)

    1988-01-01

    A reactor apparatus (10) adapted for continuously producing molten, solar grade purity elemental silicon by thermal reaction of a suitable precursor gas, such as silane (SiH.sub.4), is disclosed. The reactor apparatus (10) includes an elongated reactor body (32) having graphite or carbon walls which are heated to a temperature exceeding the melting temperature of silicon. The precursor gas enters the reactor body (32) through an efficiently cooled inlet tube assembly (22) and a relatively thin carbon or graphite septum (44). The septum (44), being in contact on one side with the cooled inlet (22) and the heated interior of the reactor (32) on the other side, provides a sharp temperature gradient for the precursor gas entering the reactor (32) and renders the operation of the inlet tube assembly (22) substantially free of clogging. The precursor gas flows in the reactor (32) in a substantially smooth, substantially axial manner. Liquid silicon formed in the initial stages of the thermal reaction reacts with the graphite or carbon walls to provide a silicon carbide coating on the walls. The silicon carbide coated reactor is highly adapted for prolonged use for production of highly pure solar grade silicon. Liquid silicon (20) produced in the reactor apparatus (10) may be used directly in a Czochralski or other crystal shaping equipment.

  16. Determination of oxygen to metal ratio for varying UO2 content in sintered (U,Th)O2 pellet by oxidation-reduction method using thermo-gravimetric analyser

    International Nuclear Information System (INIS)

    Mahanty, B.N.; Khan, F.A.; Karande, A.P.; Prakash, A.; Afzal, Md.; Panakkal, J.P.

    2009-01-01

    Experiments were carried out to determine oxygen to metal ratio in 4%, 6%, 10%, 20%, 50% and 80% UO 2 in sintered (U, Th) O 2 pellets by oxidation-reduction method using thermo gravimetric analyser. (author)

  17. INFLATE: INFlate Landing Apparatus Technology

    Science.gov (United States)

    Koryanov, V. V. K.; Da-Poian, V. D. P.

    2018-02-01

    Our project, named INFLATE (INFlatable Landing Apparatus Technology), aims at reducing space landing risks and constraints and so optimizing space missions (reducing cost, mass, and risk and in the same time improving performance).

  18. Construction apparatus for thermochemical hydrogen production process

    Energy Technology Data Exchange (ETDEWEB)

    Kubo, S.; Nakajima, H.; Higashi, S.; Onuki, K.; Akino, S.S.N. [Japan Atomic Energy Research Inst., Ibaraki-ken (Japan). Nuclear Heat Utilization Engineering Lab

    2001-06-01

    Studies have been carried out at the Japan Atomic Energy Research Institute (JAERI) on hydrogen production through thermochemical processes such as water-splitting. These studies are classified with iodine-sulphur cycle studies using heat from high temperature gas-cooled reactors. An experimental apparatus was constructed with fluorine resin, glass and quartz. It can produce hydrogen at a rate of 50 litres per hour. Electricity provides the heat required for the operation. The closed chemical process requires special control techniques. The process flow diagram for the apparatus was designed based on the results of previous studies including one where hydrogen production was successfully achieved at a rate of one liter per hour for 48 hours. Experimental operations under atmospheric pressure will be carried out for the next four years to develop the process. The data will be used in the next research and development programs aimed at designing a bench-scale apparatus. 7 refs., 1 tab., 8 figs.

  19. Apparatus for enrichment of uranium by double photoionization

    International Nuclear Information System (INIS)

    Laude, J.P.

    1983-11-01

    The present invention concerns enrichment of uranium by double photoionization. The use of a beam from a dye laser for excitation of gaseous uranium is known and the present invention concerns an apparatus of this type. The purpose of the invention is essentially to produce an apparatus having high energy efficiency. This is achieved according to the invention by using a continuous wave laser

  20. Apparatus for controlling molten core debris

    International Nuclear Information System (INIS)

    Golden, M.P.; Tilbrook, R.W.; Heylmun, N.F.

    1972-01-01

    Disclosed is an apparatus for containing, cooling, diluting, dispersing and maintaining subcritical the molten core debris assumed to melt through the bottom of a nuclear reactor pressure vessel in the unlikely event of a core meltdown. The apparatus is basically a sacrificial bed system which includes an inverted conical funnel, a core debris receptacle including a spherical dome, a spherically layered bed of primarily magnesia bricks, a cooling system of zig-zag piping in graphite blocks about and below the bed and a cylindrical liner surrounding the graphite blocks including a steel shell surrounded by firebrick. Tantalum absorber rods are used in the receptacle and bed. 9 claims, 22 figures

  1. Method and apparatus for combinatorial chemistry

    Science.gov (United States)

    Foote, Robert S [Oak Ridge, TN

    2012-06-05

    A method and apparatus are provided for performing light-directed reactions in spatially addressable channels within a plurality of channels. One aspect of the invention employs photoactivatable reagents in solutions disposed into spatially addressable flow streams to control the parallel synthesis of molecules immobilized within the channels. The reagents may be photoactivated within a subset of channels at the site of immobilized substrate molecules or at a light-addressable site upstream from the substrate molecules. The method and apparatus of the invention find particularly utility in the synthesis of biopolymer arrays, e.g., oligonucleotides, peptides and carbohydrates, and in the combinatorial synthesis of small molecule arrays for drug discovery.

  2. Apparatus Producing an Even Distribution of Strain into Carries

    Science.gov (United States)

    Hrabovský, Leopold

    2017-10-01

    In many high-rise residential buildings or multi-storey warehouses, machinery, so called lifts, is used for the vertical transportation of people or weights between two or more altitudinally distant places. Carriers used for lifts are steel ropes or sprocket chains, on which a cage or a counterbalance is hinged. Apparatus of all carriers, attached to the hinge of the cage or counterbalance, should be even. This can be made only by hammer hinge. Fixed or springe hinge cannot be a perfect equalizing apparatus. This article describes an apparatus, which allows an even distribution of the strain into lift carriers, which use springe hinge of carrier ropes.

  3. Radiographic film cassette unloading apparatus

    International Nuclear Information System (INIS)

    Stievenart, E.F.; Plessers, H.S.; Neujens, G.J.

    1980-01-01

    Apparatus for unloading cassettes, containing exposed radiographic films, has means for unfastening the cassettes, an inclined pathway for gravity feeding and rotating feed members (rollers or belts) to propel the films into the processor. (UK)

  4. Positioning and locking apparatus

    Science.gov (United States)

    Hayward, M.L.; Harper, W.H.

    1985-06-19

    A positioning and locking apparatus including a fixture having a rotatable torque ring provided with a plurality of cam segments for automatically guiding a container into a desired location within the fixture. Rotation of the ring turns the container into a final position in pressure sealing relation against a hatch member.

  5. Composição gravimétrica de resíduos sólidos aterrados Gravimetric composition of solid waste landfill

    Directory of Open Access Journals (Sweden)

    Greice Mattei

    2007-09-01

    Full Text Available A composição gravimétrica de um aterro de resíduos sólidos (RS é uma informação básica para o monitoramento e avaliação de projetos ambientais. A obtenção dessa informação é dificultada pela inexistência de procedimentos padrões de amostragem, pela heterogeneidade dos RS e pela forma de disposição desses resíduos ou tipo de aterro, entre outros fatores. Esse trabalho teve como objetivo determinar se há diferença entre a composição gravimétrica de materiais aterrados em um lixão e em um aterro controlado, além de avaliar se essa composição varia com a profundidade de amostragem. Constatou-se pouca diferença na composição gravimétrica dos RS entre os aterros. No aterro controlado predominou a massa pastosa (41,2 %, enquanto que no lixão houve maior teor de plástico filme (35,0 %. A composição dos resíduos aterrados não variou com a profundidade de amostragem.The gravimetric composition of solid waste (SW landfill is basic information for environmental monitoring and projects evaluation. The lack of standard procedures for sampling, the inherent heterogeneity of SW and the different disposal techniques of such wastes or type of landfill, among other factors, have imposed certain limitations to obtain data about landfill gravimetric composition. The objective of this work was to evaluate the difference between the gravimetric composition of SW collected from an open dump and from a controlled landfill and to evaluate if this composition changes with depth of sampling. There was little difference between the SW collected in the two types of landfills. In the controlled landfill pasted mass (41,2 % was the major component, while in the open dump the plastic film (35,0 % was the most common material. The SW composition did not change with the sampling depth.

  6. Participation and Neutrality of State Civil Apparatus in Direct Regional Election: Surabaya City Case

    Directory of Open Access Journals (Sweden)

    Catur Wibowo Budi Santoso

    2016-05-01

    Full Text Available In relation to the existence of State Civil Apparatus, at least there are two issues that must be observed in the implementation of Regional elections, namely the issues of participation and neutrality of State Civil Apparatus. The phenomenon that occurs during this time is the involvement of the State Civil Apparatus in attendance is still minimum (low. Moreover, it is believed that there are many Civil Apparatus State who is not neutral in the organization of Regional Elections. In this regard, this study aims to analyze the participation and neutrality of State Civil Apparatus. The method utilized in this study is qualitative. The result of the study shows that in general the participation of State Civil Apparatus in Surabaya is adequately good, but the neutrality of State Civil Apparatus has not implemented well enough. There are at least three (3 main factors influencing the participation of Civil State Apparatus, namely the factors of leadership exemplary, commitment to employees, and employee development. As for the neutrality of the State Civil Apparatus, among others, is influenced by the factors of the ambition of employee, primordialism, and working environment of employees.

  7. Apparatus as Milestones in the History of Comparative Psychology

    Science.gov (United States)

    Washburn, David A.; Rumbaugh, Duane M.; Putney, R. Thompson

    1994-01-01

    Significant apparatus developments from the history of comparative psychology are reviewed, including the contemporary trend toward computer use in research with nonhuman animals. It is argued that milestone apparatus served not only to open new lines of inquiry but also to shape or delimit the nature of the answers that were obtained.

  8. A Flexible Online Apparatus for Projectile Launch Experiments

    Directory of Open Access Journals (Sweden)

    Carlos Manuel Paiva

    2013-01-01

    Full Text Available In order to provide a more flexible learning environment in physics, the developed projectile launch apparatus enables students to determine the acceleration of gravity and the dependence of a set of parameters in the projectile movement. This apparatus is remotely operated and accessed via web, by first scheduling an access time slot. This machine has a number of configuration parameters that support different learning scenarios with different complexities.

  9. Self contained compressed air breathing apparatus to facilitate personnel decontamination

    International Nuclear Information System (INIS)

    McDonald, C.W.

    1963-11-01

    This report describes the modification of a Self Contained Compressed Air Breathing Apparatus to provide extended respiratory protection to grossly contaminated personnel during a decontamination period which may exceed the duration of the Breathing Apparatus air supply. (author)

  10. Self contained compressed air breathing apparatus to facilitate personnel decontamination

    Energy Technology Data Exchange (ETDEWEB)

    McDonald, C W [Radiological and Safety Division, Atomic Energy Establishment, Winfrith, Dorchester, Dorset (United Kingdom)

    1963-11-15

    This report describes the modification of a Self Contained Compressed Air Breathing Apparatus to provide extended respiratory protection to grossly contaminated personnel during a decontamination period which may exceed the duration of the Breathing Apparatus air supply. (author)

  11. THE DEVELOPMENT OF REGIONAL EXPANSION APPARATUS RESOURCE PLACEMENT IN INDONESIA

    Directory of Open Access Journals (Sweden)

    Suraji

    2018-02-01

    Full Text Available This study aimed to describe, analyze and deeply assess the implementation of regional apparatus resource development into new areas of regional expansion in Indonesia. The research was conducted by using qualitative approach, specifically, case study by analyzing descriptive data in the form of interviews, as well as analyzing valid data documentation to support the research problem. This research was conducted in the new area of Pangandaran Regency of West Java, Indonesia. The results of the research could map that there were still very few development programs of regional and apparatus expansion and it had not become the priority program after the expansion; the target of improving the quality of the apparatus resource appeared not to be the main measure, but rather, the main measure was the structuring of the apparatus and the issue of the regional office infrastructure; the instruments used in the development and training process were also less supportive, it caused many stagnant employees did not understand about new issues in the dynamics of work; apparatus development through training activities and scientific forums (seminars, scientific discussions, workshops and improvements was obstructed due to budget constraints.

  12. Thermal treatment of starch slurry in Couette-Taylor flow apparatus

    Directory of Open Access Journals (Sweden)

    Hubacz Robert

    2017-09-01

    Full Text Available In this paper, thermal processing of starch slurry in a Couette-Taylor flow (CTF apparatus was investigated. Gelatinized starch dispersion, after treatment in the CTF apparatus, was characterized using such parameters like starch granule diameters (or average diameter, starch granule swelling degree (quantifying the amount of water absorbed by starch granules and concentration of dissolved starch. These parameters were affected mostly by the process temperature, although the impact of the axial flow or rotor rotation on them was also observed. Moreover, the analysis of results showed a relatively good correlation between these parameters, as well as, between those parameter and apparent viscosity of gelatinized starch dispersion. Meanwhile, the increase in the value of the apparent viscosity and in shear-tinning behaviour of dispersion was associated with the progress of starch processing in the CTF apparatus. Finally, the CTF apparatuses of different geometries were compared using numerical simulation of the process. The results of the simulation indicated that the apparatus scaling-up without increasing the width of the gap between cylinders results in higher mechanical energy consumption per unit of processed starch slurry.

  13. UJI KONDUKTIVITAS TERMAL PADA DAUN BAYAM DENGAN MENGGUNAKAN THERMAL CONDUCTIVITY APPARATUS

    OpenAIRE

    Firmansyah, Firmansyah; Syafutra, Heriyanto; Sidikrubadi, Sidikrubadi; Irzaman, Irzaman

    2017-01-01

    Abstract Has successfully tested thermal conductivity on spinach leaves by using Thermal Conductivity Apparatus. Thermal conductivity Apparatus assisted with Steam generator, Caliper, Micrometer, and iron. The thermal conductivity value of spinach leaves is 0.5208 watts / (m.K). This thermal conductivity test on foliage, fruits using Thermal Conductivity Apparatus are very easy to do in Basic Physics Laboratory by physics study program students in Indonesia. Keywords: Thermal Conductivi...

  14. An Under-the-Table Leg-Movement Apparatus and Changes in Energy Expenditure

    Directory of Open Access Journals (Sweden)

    Gabriel A. Koepp

    2017-05-01

    Full Text Available Introduction: Deskwork contributes substantially to sedentariness. Here, we evaluated an under-the-table apparatus that was designed to promote leg movement (fidgeting while seated. Our hypothesis was that the under-the-table apparatus would increase energy expenditure.Methods: We measured energy expenditure and heart rate in 26 people while they sat and worked using a standard chair, walked on a treadmill, and sat and worked using an under-the-desk apparatus that encouraged leg movement.Results: Energy expenditure increased significantly while using the under-the-table apparatus when compared to the standard office chair (standard chair, 81 ± 18 kcal/h; under-the-table apparatus, 96 ± 23 kcal/h (P < 0.001; representing an 18 ± 16% increase. The changes in energy expenditure were not as great as walking (1 mph, 168 ± 46 kcal/h, P < 0.001; 2 mph, 205 ± 51 kcal/, P < 0.001, representing 107 ± 37% and 155 ± 48% increases over baseline, respectively.Conclusions: An under-the-table apparatus that promotes leg movement can increase energy expenditure by approximately 20%. Dynamic sitting is promoted by this apparatus and may be among a lexicon of options to help people move more while seated at work.

  15. X-ray examination apparatus

    NARCIS (Netherlands)

    2000-01-01

    The invention relates to an X-ray apparatus which includes an adjustable X-ray filter. In order to adjust an intensity profile of the X-ray beam, an X-ray absorbing liquid is transported to filter elements of the X-ray filter. Such transport is susceptible to gravitational forces which lead to an

  16. Apparatus for extracting and sequestering carbon dioxide

    Science.gov (United States)

    Rau, Gregory H [Castro Valley, CA; Caldeira, Kenneth G [Livermore, CA

    2010-02-02

    An apparatus and method associated therewith to extract and sequester carbon dioxide (CO.sub.2) from a stream or volume of gas wherein said apparatus hydrates CO.sub.2 and reacts the resulting carbonic acid with carbonate. Suitable carbonates include, but are not limited to, carbonates of alkali metals and alkaline earth metals, preferably carbonates of calcium and magnesium. Waste products are metal cations and bicarbonate in solution or dehydrated metal salts, which when disposed of in a large body of water provide an effective way of sequestering CO.sub.2 from a gaseous environment.

  17. Realtime radiation exposure monitor and control apparatus

    International Nuclear Information System (INIS)

    Cowart, R.W.

    1981-01-01

    This patent application relates to an apparatus and methods used to obtain image information from modulation of a uniform flux. An exposure measuring apparatus is disclosed which comprises a multilayered detector structure having an external circuit connected to a transparent insulating layer and to a conductive plate a radiation source adapted to irradiate the detector structure with radiation capable of producing electron-hole pairs in a photoconductive layer of the detector wherein the flow of current within the external circuit is measured when the detector is irradiated by the radiation source. (author)

  18. Apparatus and process for controlling fluidized beds

    Science.gov (United States)

    Rehmat, Amirali G.; Patel, Jitendra G.

    1985-10-01

    An apparatus and process for control and maintenance of fluidized beds under non-steady state conditions. An ash removal conduit is provided for removing solid particulates from a fluidized bed separate from an ash discharge conduit in the lower portion of the grate supporting such a bed. The apparatus and process of this invention is particularly suitable for use in ash agglomerating fluidized beds and provides control of the fluidized bed before ash agglomeration is initiated and during upset conditions resulting in stable, sinter-free fluidized bed maintenance.

  19. Development of channel inspection and gauging apparatus for 235 MWe PHWRs

    International Nuclear Information System (INIS)

    Parulkar, S.K.; Taneja, R.; Taliyan, S.S.; Singh, Manjit; Govindarajan, G.

    1992-01-01

    Channel inspection and gauging apparatus is being developed to enable in-service channel inspection and gauging. Phase I apparatus to measure annular gap between pressure tube and calandria tube in a dry channel has been developed. The apparatus consists of a gauging head and a drive mechanism. The gauging head utilities an eddy current probe to measure the annular gap between pressure tube and calandria tube and an ultrasonic sensor to measure the wall thickness of the pressure tube. The output signal of the eddy current probe needs to be corrected for the effect of pressure tube wall thickness variation. This paper gives the details of the above apparatus. The results of calibration tests at mock-up station are presented. The paper outlines the program for the phase-wise development of Channel Inspection and Gauging Apparatus for use in heavy water filled channels without their isolation from PHT and draining. The final apparatus will have the facilities for ultrasonic flaw detection, ultrasonic gauging to measure pressure tube diameter and wall thickness, an inclinometer to measure slope and sag of pressure tube and eddy current probe for the measurement of annular gap between pressure tube and calandria tube. (author). 6 figs

  20. Apparatus for the laser ablative synthesis of carbon nanotubes

    Science.gov (United States)

    Smith, Michael W.; Jordan, Kevin

    2010-02-16

    An RF-induction heated side-pumped synthesis chamber for the production of carbon nanotubes. Such an apparatus, while capable of producing large volumes of carbon nanotubes, concurrently provides a simplified apparatus that allows for greatly reduced heat up and cool down times and flexible flowpaths that can be readily modified for production efficiency optimization.

  1. Tandem mirror plasma confinement apparatus

    Science.gov (United States)

    Fowler, T. Kenneth

    1978-11-14

    Apparatus and method for confining a plasma in a center mirror cell by use of two end mirror cells as positively charged end stoppers to minimize leakage of positive particles from the ends of the center mirror cell.

  2. PNO-apparatus and its test use for neutron interferometry

    International Nuclear Information System (INIS)

    Tomimitsu, Hiroshi; Aizawa, Kazuya; Hasegawa, Yuji; Kikuta, Seishi.

    1993-01-01

    Special apparatus 'PNO' of multiutility in the so-called precise neutron optics, such as double or triple crystal diffractometry, interferometry, etc., including neutron diffraction topography, was settled at 3G beam hole in the JRR-3M. In the symposium, several applications of the PNO apparatus are presented as 1) very small angle neutron scattering tool with double crystal arrangement, 2) the characterization of the quality of artificial multilayer lattices made of Ti-Ni by a triple crystal arrangement, 3) the characterization of Ni-base superalloy single crystals by the diffraction topography, which are presented in individual sessions. Preliminary test of the neutron interferometry was also tried with the PNO apparatus. Usual monolithic Si LLL- type interferometer was used with an Al phase shifter in the neutron beam paths. The periodicity of the measured intensity curve was well corresponded to the expected one. The best contrast of the intensity curve was measured as high as 43%. The utility of the PNO-apparatus for neutron interferometry was, thus, approved. (author)

  3. Variable frequency microwave heating apparatus

    Energy Technology Data Exchange (ETDEWEB)

    Bible, D.W.; Lauf, R.J.; Johnson, A.C.; Thigpen, L.T.

    1999-10-05

    A variable frequency microwave heating apparatus (10) designed to allow modulation of the frequency of the microwaves introduced into a multi-mode microwave cavity (34) for testing or other selected applications. The variable frequency microwave heating apparatus (10) includes a microwave signal generator (12) and a high-power microwave amplifier (20) or a high-power microwave oscillator (14). A power supply (22) is provided for operation of the high-power microwave oscillator (14) or microwave amplifier (20). A directional coupler (24) is provided for detecting the direction and amplitude of signals incident upon and reflected from the microwave cavity (34). A first power meter (30) is provided for measuring the power delivered to the microwave furnace (32). A second power meter (26) detects the magnitude of reflected power. Reflected power is dissipated in the reflected power load (28).

  4. A steam separator-superheater apparatus

    International Nuclear Information System (INIS)

    Androw, Jean; Bessouat, Roger; Peyrelongue, J.-P.

    1973-01-01

    Description is given of a separator-superheater apparatus comprising an outer enclosure containing a separating-unit and a steam superheating unit according to the main patent. The present addition relates to an improvement in that apparatus, characterized in that the separating unit and the superheating unit, mounted in two distinct portions of the outer enclosure, are divided into the same number of sub-units of each unit being identical and operating in parallel, and in that to each separator sub-unit is associated a superheater sub-unit, said sub-units being mounted in series and located in one in the other of the enclosure two portions, respectively. This can be applied to the treatment of the exhaust steam of a turbine high pressure body, prior to re-injecting said steam into the low pressure body [fr

  5. Rescue apparatus for a high working oil derrick

    Energy Technology Data Exchange (ETDEWEB)

    Prokopov, O.P.; Yagudin, S.Z.

    1980-05-18

    In order to improve reliability of the rescue apparatus a device for lowering a basket is made in the form of a collapsible forked support installed in the vertical plane inclined away from the tower. Its lower ends are attached by hinges to the base of the derrick. The upper end is connected to the derrick by means of a fastener. The apparatus has brakes with shock straps for receiving forked support.

  6. Simple and Low-Cost Exposed -Layer Grain Drying Apparatus ...

    African Journals Online (AJOL)

    Thin-layer drying apparatus was developed from standard “off-the- shelf” equipment: a fan convection laboratory oven and a weighing scale. Using this apparatus the thin-layer drying data for wheat under constant conditions were obtained for a range of drying air temperature from 30°C to 150°C and the initial moisture ...

  7. A new apparatus at hyper irradiation research facility at the Atomic Research Center, University of Tokyo

    International Nuclear Information System (INIS)

    Shibata, Hiromi; Iwai, Takeo; Narui, Makoto; Omata, Takao

    1996-01-01

    In the hyper irradiation research facility at the Atomic Research Center, the University of Tokyo, following apparatuses were newly installed for accelerator relating apparatus on 1995 fiscal year; 1) Hyper ion microbeam analysis apparatus, 2) Fourier conversion infrared microscopy, 3) Pico second two-dimensional fluorescence measuring apparatus, 4) Femto second wave-length reversible pulse laser radiation apparatus, and others. In addition to double irradiation, pulse beam irradiation experiment and so forth characteristic in conventional hyper irradiation research apparatus, upgrading of material irradiation experiments using these new apparatuses are intended. (G.K.)

  8. A new apparatus at hyper irradiation research facility at the Atomic Research Center, University of Tokyo

    Energy Technology Data Exchange (ETDEWEB)

    Shibata, Hiromi; Iwai, Takeo; Narui, Makoto; Omata, Takao [Tokyo Univ. (Japan). Research Center for Nuclear Science and Technology

    1996-12-01

    In the hyper irradiation research facility at the Atomic Research Center, the University of Tokyo, following apparatuses were newly installed for accelerator relating apparatus on 1995 fiscal year; (1) Hyper ion microbeam analysis apparatus, (2) Fourier conversion infrared microscopy, (3) Pico second two-dimensional fluorescence measuring apparatus, (4) Femto second wave-length reversible pulse laser radiation apparatus, and others. In addition to double irradiation, pulse beam irradiation experiment and so forth characteristic in conventional hyper irradiation research apparatus, upgrading of material irradiation experiments using these new apparatuses are intended. (G.K.)

  9. Polarization Imaging Apparatus with Auto-Calibration

    Science.gov (United States)

    Zou, Yingyin Kevin (Inventor); Zhao, Hongzhi (Inventor); Chen, Qiushui (Inventor)

    2013-01-01

    A polarization imaging apparatus measures the Stokes image of a sample. The apparatus consists of an optical lens set, a first variable phase retarder (VPR) with its optical axis aligned 22.5 deg, a second variable phase retarder with its optical axis aligned 45 deg, a linear polarizer, a imaging sensor for sensing the intensity images of the sample, a controller and a computer. Two variable phase retarders were controlled independently by a computer through a controller unit which generates a sequential of voltages to control the phase retardations of the first and second variable phase retarders. A auto-calibration procedure was incorporated into the polarization imaging apparatus to correct the misalignment of first and second VPRs, as well as the half-wave voltage of the VPRs. A set of four intensity images, I(sub 0), I(sub 1), I(sub 2) and I(sub 3) of the sample were captured by imaging sensor when the phase retardations of VPRs were set at (0,0), (pi,0), (pi,pi) and (pi/2,pi), respectively. Then four Stokes components of a Stokes image, S(sub 0), S(sub 1), S(sub 2) and S(sub 3) were calculated using the four intensity images.

  10. Determination of total dietary fiber (CODEX definition) by enzymatic-gravimetric method and liquid chromatography: collaborative study.

    Science.gov (United States)

    McCleary, Barry V; DeVries, Jonathan W; Rader, Jeanne I; Cohen, Gerald; Prosky, Leon; Mugford, David C; Champ, Martine; Okuma, Kazuhiro

    2010-01-01

    A method for the determination of total dietary fiber (TDF), as defined by the CODEX Alimentarius, was validated in foods. Based upon the principles of AOAC Official Methods 985.29, 991.43, 2001.03, and 2002.02, the method quantitates high- and low-molecular-weight dietary fiber (HMWDF and LMWDF, respectively). In 2007, McCleary described a method of extended enzymatic digestion at 37 degrees C to simulate human intestinal digestion followed by gravimetric isolation and quantitation of HMWDF and the use of LC to quantitate low-molecular-weight soluble dietary fiber (LMWSDF). The method thus quantitates the complete range of dietary fiber components from resistant starch (by utilizing the digestion conditions of AOAC Method 2002.02) to digestion resistant oligosaccharides (by incorporating the deionization and LC procedures of AOAC Method 2001.03). The method was evaluated through an AOAC collaborative study. Eighteen laboratories participated with 16 laboratories returning valid assay data for 16 test portions (eight blind duplicates) consisting of samples with a range of traditional dietary fiber, resistant starch, and nondigestible oligosaccharides. The dietary fiber content of the eight test pairs ranged from 11.57 to 47.83%. Digestion of samples under the conditions of AOAC Method 2002.02 followed by the isolation and gravimetric procedures of AOAC Methods 985.29 and 991.43 results in quantitation of HMWDF. The filtrate from the quantitation of HMWDF is concentrated, deionized, concentrated again, and analyzed by LC to determine the LMWSDF, i.e., all nondigestible oligosaccharides of degree of polymerization > or =3. TDF is calculated as the sum of HMWDF and LMWSDF. Repeatability standard deviations (Sr) ranged from 0.41 to 1.43, and reproducibility standard deviations (S(R)) ranged from 1.18 to 5.44. These results are comparable to other official dietary fiber methods, and the method is recommended for adoption as Official First Action.

  11. Tandem mirror plasma confinement apparatus

    International Nuclear Information System (INIS)

    Fowler, T.K.

    1978-01-01

    Apparatus and method are described for confining a plasma in a center mirror cell by use of two end mirror cells as positively charged end stoppers to minimize leakage of positive particles from the ends of the center mirror cell

  12. Automatic emissive probe apparatus for accurate plasma and vacuum space potential measurements

    Science.gov (United States)

    Jianquan, LI; Wenqi, LU; Jun, XU; Fei, GAO; Younian, WANG

    2018-02-01

    We have developed an automatic emissive probe apparatus based on the improved inflection point method of the emissive probe for accurate measurements of both plasma potential and vacuum space potential. The apparatus consists of a computer controlled data acquisition card, a working circuit composed by a biasing unit and a heating unit, as well as an emissive probe. With the set parameters of the probe scanning bias, the probe heating current and the fitting range, the apparatus can automatically execute the improved inflection point method and give the measured result. The validity of the automatic emissive probe apparatus is demonstrated in a test measurement of vacuum potential distribution between two parallel plates, showing an excellent accuracy of 0.1 V. Plasma potential was also measured, exhibiting high efficiency and convenient use of the apparatus for space potential measurements.

  13. Apparatus for decomposing shale

    Energy Technology Data Exchange (ETDEWEB)

    Gislain, M

    1865-06-20

    The apparatus is designed to fulfill the three following conditions: (1) complete extraction of the mineral oil, by avoiding partial decomposition; (2) purification of the said oil from products formed in the decomposition of the shale; (3) breaking down of the said oil into more products of different density. The separation of the heavy and bituminous products is claimed.

  14. Global detailed gravimetric geoid. [based on gravity model derived from satellite tracking and surface gravity data

    Science.gov (United States)

    Vincent, S.; Marsh, J. G.

    1973-01-01

    A global detailed gravimetric geoid has been computed by combining the Goddard Space Flight Center GEM-4 gravity model derived from satellite and surface gravity data and surface 1 deg-by-1 deg mean free air gravity anomaly data. The accuracy of the geoid is + or - 2 meters on continents, 5 to 7 meters in areas where surface gravity data are sparse, and 10 to 15 meters in areas where no surface gravity data are available. Comparisons have been made with the astrogeodetic data provided by Rice (United States), Bomford (Europe), and Mather (Australia). Comparisons have also been carried out with geoid heights derived from satellite solutions for geocentric station coordinates in North America, the Caribbean, Europe, and Australia.

  15. Handling apparatus for a nuclear reactor fuel assembly

    International Nuclear Information System (INIS)

    Shallenberger, J.M.; Hornak, L.P.; Desmarchais, W.E.

    1978-01-01

    An apparatus is disclosed for handling radioactive fuel assembly during transfer operations. The radioactive fuel assembly is drawn up into a shielding sleeve which substantially reduces the level of radioactivity immediately surrounding the sleeve thereby permitting direct access by operating personnel. The lifting assembly which draws the fuel assembly up within the shielding sleeve is mounted to and forms an integral part of the handling apparatus. The shielding sleeve accompanies the fuel assembly during all of the transfer operations

  16. A study on dehydration of rare earth chloride hydrate

    International Nuclear Information System (INIS)

    Cho, Yong Zun; Eun, Hee Chul; Son, Sung Mo; Lee, Tae Kyo; Hwang, Taek Sung

    2012-01-01

    The dehydration schemes of rare earth (La, Ce, Nd, Pr, Sm. Eu, Gd, Y) chloride hydrates was investigated by using a dehydration apparatus. To prevent the formation of the rare earth oxychlorides, the operation temperature was changed step by step (80→150→230 degree C) based on the TGA (thermo-gravimetric analysis) results of the rare earth chloride hydrates. A vacuum pump and preheated Ar gas were used to effectively remove the evaporated moisture and maintain an inert condition in the dehydration apparatus. The dehydration temperature of the rare earth chloride hydrate was increased when the atomic number of the rare earth nuclide was increased. The content of the moisture in the rare earth chloride hydrate was decreased below 10% in the dehydration apparatus.

  17. Apparatus for treating carcinoma of the uterine cervix

    International Nuclear Information System (INIS)

    Kumar, P.P.

    1984-01-01

    Disclosed is an apparatus for treating carcinoma of the uterine cervix by judiciously applying radioactive material immediately adjacent the uterine cervix for an extended period of time empirically determined by the radiologist. The novel apparatus comprises three radioactively chargeable components including a central tubular tandem vaginally insertable longitudinally into the uterine cervix and two non-lineal tubular ovoidal assemblies longitudinally locatable at the cervix and positioned laterally between the respective vaginal walls and the uterine cervix. The ovoidal assemblies are conveniently removably and pivotably connected to the central tandem component externally of the vaginal along the sagittal plane through a novel adapter member whereby the radioactively chargeable ovoidal assemblies tend to remain within a laterally extending plane located substantially midway the transversely separated vasicovaginal and rectovaginal septa, even though the patient periodically shifts her reclining posture during the extended treatment by said vaginally protruding apparatus

  18. A FILTRATION METHOD AND APPARATUS

    DEFF Research Database (Denmark)

    2003-01-01

    The present invention concerns a method and an apparatus for separating dry matter from liquid, comprising providing an enclosed separation environment capable of being pressure regulated, and in said enclosed separation environment contacting at least one filter with a suspension accumulating dr...

  19. Nuclear fuel rod loading apparatus

    International Nuclear Information System (INIS)

    King, H.B.

    1981-01-01

    A nuclear fuel loading apparatus, incorporating a microprocessor control unit, is described which automatically loads nuclear fuel pellets into dual fuel rods with a minimum of manual involvement and in a manner and sequence to ensure quality control and accuracy. (U.K.)

  20. Apparatuses and methods for generating electric fields

    Science.gov (United States)

    Scott, Jill R; McJunkin, Timothy R; Tremblay, Paul L

    2013-08-06

    Apparatuses and methods relating to generating an electric field are disclosed. An electric field generator may include a semiconductive material configured in a physical shape substantially different from a shape of an electric field to be generated thereby. The electric field is generated when a voltage drop exists across the semiconductive material. A method for generating an electric field may include applying a voltage to a shaped semiconductive material to generate a complex, substantially nonlinear electric field. The shape of the complex, substantially nonlinear electric field may be configured for directing charged particles to a desired location. Other apparatuses and methods are disclosed.

  1. Methods and apparatus for controlling rotary machines

    Science.gov (United States)

    Bagepalli, Bharat Sampathkumaran [Niskayuna, NY; Jansen, Patrick Lee [Scotia, NY; Barnes, Gary R [Delanson, NY; Fric, Thomas Frank [Greer, SC; Lyons, James Patrick Francis [Niskayuna, NY; Pierce, Kirk Gee [Simpsonville, SC; Holley, William Edwin [Greer, SC; Barbu, Corneliu [Guilderland, NY

    2009-09-01

    A control system for a rotary machine is provided. The rotary machine has at least one rotating member and at least one substantially stationary member positioned such that a clearance gap is defined between a portion of the rotating member and a portion of the substantially stationary member. The control system includes at least one clearance gap dimension measurement apparatus and at least one clearance gap adjustment assembly. The adjustment assembly is coupled in electronic data communication with the measurement apparatus. The control system is configured to process a clearance gap dimension signal and modulate the clearance gap dimension.

  2. Purged window apparatus utilizing heated purge gas

    Science.gov (United States)

    Ballard, Evan O.

    1984-01-01

    A purged window apparatus utilizing tangentially injected heated purge gases in the vicinity of electromagnetic radiation transmitting windows, and a tapered external mounting tube to accelerate these gases to provide a vortex flow on the window surface and a turbulent flow throughout the mounting tube. Use of this apparatus prevents backstreaming of gases under investigation which are flowing past the mouth of the mounting tube which would otherwise deposit on the windows. Lengthy spectroscopic investigations and analyses can thereby be performed without the necessity of interrupting the procedures in order to clean or replace contaminated windows.

  3. Method for Surface Scanning in Medical Imaging and Related Apparatus

    DEFF Research Database (Denmark)

    2015-01-01

    A method and apparatus for surface scanning in medical imaging is provided. The surface scanning apparatus comprises an image source, a first optical fiber bundle comprising first optical fibers having proximal ends and distal ends, and a first optical coupler for coupling an image from the image...

  4. Medical radiological apparatus

    International Nuclear Information System (INIS)

    1980-01-01

    With the apparatus described, images can be obtained by rotation scanning and the image formation from a three dimensional image matrix is converted into an overall picture. Detectors for both X-ray radiation and γ radiation are present and these consist of a row of detector elements, from each of which a separate read-out can be obtained. Therefore both X-ray and γ ray images emitted from the examined object can be obtained. (Th.P.)

  5. Apparatus to examine pulsed parallel field losses in large conductors

    International Nuclear Information System (INIS)

    Miller, J.R.; Shen, S.S.

    1977-01-01

    Conductors in tokamak toroidal field coils will be exposed to pulsed fields both parallel and perpendicular to the current direction. These conductors will likely be quite high capacity (10 to 20 kA) and therefore probably will be built up out of smaller units. We have previously published measurements of losses in conductors exposed to a pulsed parallel field, but those experiments necessarily used monolithic conductors of relatively small cross section because the pulse coil, a torus that surrounded the test conductor, was itself small. Here we describe an apparatus that is conceptually similar but has been scaled up to accept conductors of much larger cross section and current capacity. The apparatus consists basically of a superconducting torus that contains a movable spool to allow test samples to be wound inside without unwinding the torus. Details of apparatus design and capabilities are described and preliminary results from tests of the apparatus and from loss measurements using it are reported

  6. Comparison of gas chromatographic and gravimetric methods for quantization of total fat and fatty acids in foodstuffs

    Directory of Open Access Journals (Sweden)

    Sabria Aued-Pimentel

    2010-01-01

    Full Text Available Different methods to determine total fat (TF and fatty acids (FA, including trans fatty acids (TFA, in diverse foodstuffs were evaluated, incorporating gravimetric methods and gas chromatography with flame ionization detector (GC/FID, in accordance with a modified AOAC 996.06 method. Concentrations of TF and FA obtained through these different procedures diverged (p< 0.05 and TFA concentrations varied beyond 20 % of the reference values. The modified AOAC 996.06 method satisfied both accuracy and precision, was fast and employed small amounts of low toxicity solvents. Therefore, the results showed that this methodology is viable to be adopted in Brazil for nutritional labeling purposes.

  7. Reference on shooting-blasting apparatus. Spravochnik po prostrelochno-vzryvnoy apparature

    Energy Technology Data Exchange (ETDEWEB)

    Fridlyander, L Ya

    1983-01-01

    Purpose, device, technical characteristics of the preforators, powder generators, blasting packers, core lifter, torpedoes, equipment and technology of charging, storage, transporting and testing of apparatus, characteristic errors and elimination of them are presented. Recommendations are made for safe work and efficient use of apparatus in different geological-technical conditions.

  8. Combustion engine variable compression ratio apparatus and method

    Science.gov (United States)

    Lawrence,; Keith, E [Peoria, IL; Strawbridge, Bryan E [Dunlap, IL; Dutart, Charles H [Washington, IL

    2006-06-06

    An apparatus and method for varying a compression ratio of an engine having a block and a head mounted thereto. The apparatus and method includes a cylinder having a block portion and a head portion, a piston linearly movable in the block portion of the cylinder, a cylinder plug linearly movable in the head portion of the cylinder, and a valve located in the cylinder plug and operable to provide controlled fluid communication with the block portion of the cylinder.

  9. Apparatus and Method for Communication over Power Lines

    Science.gov (United States)

    Krasowski, Michael J. (Inventor); Prokop, Norman F. (Inventor); Greer, III, Lawrence C. (Inventor); Nappier, Jennifer M. (Inventor)

    2017-01-01

    An apparatus and method are provided for communicating over power lines. The apparatus includes a coupling modem that is situated between a power line and a device. The coupling modem is configured to demodulate a signal received from the power line into a sine signal and a cosine signal. The coupling modem is also configured to modulate a communicated bit stream received from the device into a transmitted signal in order to impose the transmitted signal onto the power line.

  10. Development of an experimental apparatus for boiling analysis

    International Nuclear Information System (INIS)

    Castro, A.J.A. de.

    1984-04-01

    The nucleate boiling is the most interesting boiling regime for practical appliccations, including nuclear reactor engineering. such regime is characterized by very high heat transfer rates with only small surface superheating. An experimental apparatus is developed for studying parameters which affect nucleate boiling. The following parameters are analysed: pressure, fluid velocity and the fluid temperature at the test section entrance. The performance of experimental apparatus is analysed by results and by problems raised by the oeration of setup. (Author) [pt

  11. Isotope separation apparatus

    International Nuclear Information System (INIS)

    Lyon, R.K.; Eisner, P.N.; Thomas, W.R.I.

    1983-01-01

    This application discloses a method for and an apparatus in which isotopes of an element in a compared are separated from each other while that compound, i.e., including a mixture of such isotopes, flows along a predetermined path. The apparatus includes a flow tube having a beginning and an end. The mixture of isotopes is introduced into the flow tube at a first introduction point between the beginning and the end thereof to flow the mixture toward the end thereof. A laser irradiates the flow tube dissociating compounds of a preselected one of said isotopes thereby converting the mixture in an isotopically selective manner. The dissociation products are removed from the tube at a first removal point between the first introduction point and the end. The dissociation product removed at the the first removal point are reconverted back into the comound thereby providing a first stage enriched compound. This first stage enriched compound is reintroduced into the flow tube at a second introduction point between the beginning thereof and the first introduction point. Further product is removed from the flow tube at a second removal point between the second introduction point and the first introduction point. The second introduction point is chosen so that the isotope composition of the first stage enriched compound is approximately the same as that of the compound in the flow tube

  12. Electrolysis apparatus and method

    International Nuclear Information System (INIS)

    1975-01-01

    A procedure in which electrolysis is combined with radiolysis to improve the reaction yield is proposed for the production of hydrogen and oxygen from water. An apparatus for this procedure is disclosed. High-energy electric pulses are applied between the anode and kathode of an electrolytical cell in such a way that short-wave electromagnetic radiation is generated at the same time

  13. Apparatus for obtaining radiographs

    International Nuclear Information System (INIS)

    Frank, L.F.

    1977-01-01

    An apparatus for making x-ray pictures by imagewise exposing a cloud chamber containing a high atomic number gas mixed with a condensate vapor is described. The gas is under sufficiently high pressure to assure substantially complete absorption of the incident x-rays. Optical means are provided so that visible x-ray tracks are viewed from a direction aligned with the tracks

  14. Calculation of period processing solution syrup in vacuum apparatus

    Directory of Open Access Journals (Sweden)

    A. A. Slavyanskii

    2016-01-01

    Full Text Available Important and crucial element in the management of the technological flow of production of sugar product standards is the period of time the enrichment of massecuite, since its neutralization in the process of crystal formation in vacuum apparatus, excess sugar solution. Although currently proposed and implemented in the industry, including as a front-end accompany the process, a number of ways in the real world sugar production in many cases have to resort to the services of an experienced operator. It is obvious that in any case it is necessary to have a surround-dependent glucose solution data on time for the excess sugar solution into the vacuum apparatus. With regard to the period of the enrichment of depleted sucrose solution are entered into this substance excess sucrose solution, it should be noted that this problem is theoretically still insufficiently developed. It is obvious that for practical purposes it is desirable to have a simple and convenient for engineering calculation of sugar processing time dependencies of the specified volume of water from the operating parameters of the process (the required concentration of sucrose, temperature of the solution stirring. The problem is the quantitative analysis of sucrose crystallization in vacuum apparatus, including the timing of enrichment solution to the excess syrup, period of time processing massecuite total this apparatus has been investigated in many works. However, due to its importance to the task of obtaining commercial sugar high standards this issue required further in-depth examination. In the article to support the enrichment process solution sucrose due to neutralize this solvent system in vacuum apparatus, from the standpoint of diffusion theory provides a more reasonable compared to known so far, quantitative analysis of this process. Where as sucrose crystals team are considering a system of balls, uniformly distributed in vacuum apparatus. On the basis of the solution

  15. Filtering apparatus and method for mixing, extraction and/or separation

    DEFF Research Database (Denmark)

    2013-01-01

    The present invention relates to a filtering apparatus and method for mixing a compound of solid and fluid phases, separating the phases and/or extracting fluid from the compound. One embodiment of the invention discloses a filtering apparatus comprising a first filter section accommodating a fir...... in a beer brewing procedure....

  16. Apparatus and method for tracking a molecule or particle in three dimensions

    Science.gov (United States)

    Werner, James H [Los Alamos, NM; Goodwin, Peter M [Los Alamos, NM; Lessard, Guillaume [Santa Fe, NM

    2009-03-03

    An apparatus and method were used to track the movement of fluorescent particles in three dimensions. Control software was used with the apparatus to implement a tracking algorithm for tracking the motion of the individual particles in glycerol/water mixtures. Monte Carlo simulations suggest that the tracking algorithms in combination with the apparatus may be used for tracking the motion of single fluorescent or fluorescently labeled biomolecules in three dimensions.

  17. Digital Self-Evaluation and the Cybernetic Regime: A Sketch for a Materialist Apparatus Analysis

    Directory of Open Access Journals (Sweden)

    Simon Schaupp

    2017-12-01

    Full Text Available Using the example of self-tracking, this paper develops a materialist approach to the methodology of apparatus analysis. It builds on the Foucauldian concept of the apparatus, which it then subdivides into micro apparatus, as a concrete digital technology, and macro apparatus, as the superordinate regime to which the micro apparatus contributes. To bridge these two concepts, the term of the “urgent need” is used for asking to which broader social problems a given apparatus reacts. Contrary to approaches of “new materialism”, this paper insists on an analytical divide between discourse and matter on the one hand and action structure on the other hand, to be able to consider politico-economic power relations. Using this methodology, the relationship between the techno-practice of self-tracking and a broader cybernetic regime, is illustrated.

  18. Apparatus and method for enhancing tissue repair in mammals

    Science.gov (United States)

    Goodwin, Thomas J. (Inventor); Parker, Clayton R. (Inventor)

    2009-01-01

    An apparatus is introduced for the use of enhancing tissue repair in mammals. The apparatus includes a sleeve; an electrically conductive coil; a sleeve support; an electrical circuit configured to supply the coil with a square wave time varying electrical current sufficient to create approximately 0.05 gauss to 0.5 gauss. When in use, the sleeve of the apparatus is placed on a mammalian body part and the time varying electromagnetic force of from approximately 0.05 gauss to 0.5 gauss is generated on the mammalian body for an extended period of time so that the tissue is encouraged to be regenerated in the mammalian body part at a rate in excess of the normal tissue regeneration rate relative to regeneration without application of the time varying electromagnetic force.

  19. Radiography apparatus

    International Nuclear Information System (INIS)

    Vasseur, J.P.

    1976-01-01

    A novel apparatus for radiographic examination purposes comprising an x-ray source emitting a flat beam is described. Detectors are arranged in the plane of the beam in order each to pick up part of the beam. To avoid the Compton effect, each detector has associated with it an auxiliary detector which only receives the rays emitted by the Compton effect. An electrical circuit forms a predetermined linear combination of the signals respectively picked up by each detector and the associated auxiliary detector, this in order to prevent the errors which are due to the Compton effect when the beam passes through the body being analyzed

  20. To what extent can aerosol water explain the discrepancy between model calculated and gravimetric PM10 and PM2.5?

    Directory of Open Access Journals (Sweden)

    S. G. Tsyro

    2005-01-01

    Full Text Available Inter-comparisons of European air quality models show that regional transport models, including the EMEP (Co-operative Programme for monitoring and evaluation of the long-range transmission of air pollutants in Europe aerosol model, tend to underestimate the observed concentrations of PM10 and PM2.5. Obviously, an accurate representation of the individual aerosol constituents is a prerequisite for adequate calculation of PM concentrations. On the other hand, available measurements on the chemical characterization of ambient particles reveal that full chemical PM mass closure is rarely achieved. The fraction unaccounted for by chemical analysis can comprise as much as 30-40% of gravimetric PM10 or PM2.5 mass. The unaccounted PM mass can partly be due to non-C atoms in organic aerosols and/or due to sampling and measurement artefacts. Moreover, a part of the unaccounted PM mass is likely to consist of water associated with particles. Thus, the gravimetrically measured particle mass does not necessarily represent dry PM10 and PM2.5 mass. This is thought to be one of the reasons for models under-prediction of observed PM, if calculated dry PM10 and PM2.5 concentrations are compared with measurements. The EMEP aerosol model has been used to study to what extent particle-bound water can explain the chemically unidentified PM mass in filter-based particle samples. Water content of PM2.5 and PM10 has been estimated with the model for temperature 20°C and relative humidity 50%, which are conditions required for equilibration of dust-loaded filters according to the Reference method recommended by the European Committee for Standardization (CEN. Model calculations for Europe show that, depending on particle composition, particle-bound water constitutes 20-35% of the annual mean PM10 and PM2.5 concentrations, which is consistent with existing experimental estimates. At two Austrian sites, in Vienna and Streithofen, where daily measurements of PM2.5 mass

  1. Morphology of the hyoid apparatus of some species of odontocetes from southern Brazil.

    Directory of Open Access Journals (Sweden)

    Dan Jacobs Pretto

    2009-03-01

    Full Text Available The hyoid apparatus of odontocetes serves as a major attachment point for the muscles and ligaments that subserve breathing, sound production and swallowing. However, most of the literature on anatomy does not consider the bones of this region, presenting general osteological descriptions without considering the comparative aspects. This study sought to determine the intra and interspecific variations of the ossified hyoid apparatus elements from six species of odontocetus. We studied 96 hyoid apparatuses from the following species: Phocoena spinipinnis (n = 1, Pontoporia blainvillei (n = 20, Sotalia guianensis (n = 37, Stenella frontalis (n = 13, Steno bredanensis (n = 6 and Tursiops truncatus (n = 19. Among the six species analyzed, P. spinipinnis, P. blainvillei and S. guianenses presented a diagnostic feature of this apparatus, while the others were best described morphometrically when considering all the hyoid apparatus bones. Intraspecific variation was registered with greater amplitude in T. truncatus, while S. guianensis showed sexual dimorphism. The morphology of the hyoid apparatus proved to be important in the differentiation and characterization of all studied species.

  2. Method And Apparatus For Atomizing And Vaporizing Liquid

    KAUST Repository

    Lal, Amit; Mayet, Abdulilah M.

    2014-01-01

    A method and apparatus for atomizing and vaporizing liquid is described. An apparatus having an ejector configured to eject one or more droplets of liquid may be inserted into a reservoir containing liquid. The ejector may have a vibrating device that vibrates the ejector and causes liquid to move from the reservoir up through the ejector and out through an orifice located on the top of the ejector. The one or more droplets of liquid ejected from the ejector may be heated and vaporized into the air.

  3. Method And Apparatus For Atomizing And Vaporizing Liquid

    KAUST Repository

    Lal, Amit

    2014-09-18

    A method and apparatus for atomizing and vaporizing liquid is described. An apparatus having an ejector configured to eject one or more droplets of liquid may be inserted into a reservoir containing liquid. The ejector may have a vibrating device that vibrates the ejector and causes liquid to move from the reservoir up through the ejector and out through an orifice located on the top of the ejector. The one or more droplets of liquid ejected from the ejector may be heated and vaporized into the air.

  4. Double bypasses soxhlet apparatus for extraction of piperine from Piper nigrum

    OpenAIRE

    Subramanian, R.; Subbramaniyan, P.; Noorul Ameen, J.; Raj, V.

    2016-01-01

    A simple modified soxhlet extractor, double bypasses sidearm soxhlet apparatus (DBSA) was designed and employed for extraction of piperine from Piper nigrum. Total extraction time, time taken for a cycle and yield observed in the double bypass sidearm soxhlet apparatus was compared with the soxhlet apparatus. Extraction time, time taken for an extraction cycle and yield of crude piperine obtained in DBSA were 12 ± 1 h, 8 ± 1.00 min, and 3.90 ± 0.10 g whereas the results obtained in the soxhle...

  5. Gram staining apparatus for space station applications

    Science.gov (United States)

    Molina, T. C.; Brown, H. D.; Irbe, R. M.; Pierson, D. L.

    1990-01-01

    A self-contained, portable Gram staining apparatus (GSA) has been developed for use in the microgravity environment on board the Space Station Freedom. Accuracy and reproducibility of this apparatus compared with the conventional Gram staining method were evaluated by using gram-negative and gram-positive controls and different species of bacteria grown in pure cultures. A subsequent study was designed to assess the performance of the GSA with actual specimens. A set of 60 human and environmental specimens was evaluated with the GSA and the conventional Gram staining procedure. Data obtained from these studies indicated that the GSA will provide the Gram staining capability needed for the microgravity environment of space.

  6. Apparatus for isotopic alteration of mercury vapor

    Science.gov (United States)

    Grossman, Mark W.; George, William A.; Marcucci, Rudolph V.

    1988-01-01

    An apparatus for enriching the isotopic Hg content of mercury is provided. The apparatus includes a reactor, a low pressure electric discharge lamp containing a fill including mercury and an inert gas. A filter is arranged concentrically around the lamp. In a preferred embodiment, constant mercury pressure is maintained in the filter by means of a water-cooled tube that depends from it, the tube having a drop of mercury disposed in it. The reactor is arranged around the filter, whereby radiation from said lamp passes through the filter and into said reactor. The lamp, the filter and the reactor are formed of a material which is transparent to ultraviolet light.

  7. Multidimensional structured data visualization method and apparatus, text visualization method and apparatus, method and apparatus for visualizing and graphically navigating the world wide web, method and apparatus for visualizing hierarchies

    Science.gov (United States)

    Risch, John S [Kennewick, WA; Dowson, Scott T [West Richland, WA; Hart, Michelle L [Richland, WA; Hatley, Wes L [Kennewick, WA

    2008-05-13

    A method of displaying correlations among information objects comprises receiving a query against a database; obtaining a query result set; and generating a visualization representing the components of the result set, the visualization including one of a plane and line to represent a data field, nodes representing data values, and links showing correlations among fields and values. Other visualization methods and apparatus are disclosed.

  8. Effect of ionic liquids, 1-butyl-3-methyl imidazolium bromide and 1-hexyl-3-methyl imidazolium bromide on the vapour – Liquid equilibria of the aqueous D-fructose solutions at 298.15 K and atmospheric pressure using isopiestic method

    International Nuclear Information System (INIS)

    Zafarani-Moattar, Mohammed Taghi; Shekaari, Hemayat; Mazaher Haji Agha, Elnaz

    2017-01-01

    Highlights: • VLE data for aqueous fructose + [BMIm]Br or [HMIm]Br systems were measured. • Performances of different local composition models were tested in fitting VLE data. • Molal activity coefficients were calculated. • The results were discussed on basis of water, IL and sugar interactions. - Abstract: In this study, water activity measurements have been carried out by the isopiestic method for the systems (D-fructose + 1-butyl-3-methyl imidazolium bromide + H 2 O) and (D-fructose + 1-hexyl-3-methyl imidazolium bromide + H 2 O) at 298.15 K and atmospheric pressure. Vapour pressures and osmotic coefficients of the solutions have been determined from the experimental measured water activity results. The experimental water activity values were satisfactorily correlated with segment-based local composition models of the Wilson, NRTL, modified NRTL, NRF-NRTL and UNIQUAC. Then, using the parameters obtained from these models, the unsymmetrical molal activity coefficients of the D-fructose and ionic liquids in the binary and D-fructose in ternary aqueous solutions have been calculated. Furthermore, the activity coefficients of D-fructose in binary and ternary solutions were used to calculate the Gibbs energy of transfer for D-fructose from water to aqueous ionic liquid solutions. An application of McMillan-Mayer theory of solutions through virial expansion of transfer Gibbs energy was made to get pair and triplet interaction parameters and salting constant values. From the sign and magnitude of these parameters and salting constants and also from the magnitude of activity coefficients some information about solute-solute and solute-solvent interactions are obtained.

  9. Spectroscopic Chemical Analysis Methods and Apparatus

    Science.gov (United States)

    Hug, William F. (Inventor); Reid, Ray D. (Inventor); Bhartia, Rohit (Inventor); Lane, Arthur L. (Inventor)

    2018-01-01

    Spectroscopic chemical analysis methods and apparatus are disclosed which employ deep ultraviolet (e.g. in the 200 nm to 300 nm spectral range) electron beam pumped wide bandgap semiconductor lasers, incoherent wide bandgap semiconductor light emitting devices, and hollow cathode metal ion lasers to perform non-contact, non-invasive detection of unknown chemical analytes. These deep ultraviolet sources enable dramatic size, weight and power consumption reductions of chemical analysis instruments. In some embodiments, Raman spectroscopic detection methods and apparatus use ultra-narrow-band angle tuning filters, acousto-optic tuning filters, and temperature tuned filters to enable ultra-miniature analyzers for chemical identification. In some embodiments Raman analysis is conducted along with photoluminescence spectroscopy (i.e. fluorescence and/or phosphorescence spectroscopy) to provide high levels of sensitivity and specificity in the same instrument.

  10. Cluster Implantation and Deposition Apparatus

    DEFF Research Database (Denmark)

    Hanif, Muhammad; Popok, Vladimir

    2015-01-01

    In the current report, a design and capabilities of a cluster implantation and deposition apparatus (CIDA) involving two different cluster sources are described. The clusters produced from gas precursors (Ar, N etc.) by PuCluS-2 can be used to study cluster ion implantation in order to develop...

  11. Apparatus for measuring fluid flow

    Science.gov (United States)

    Smith, J.E.; Thomas, D.G.

    Flow measuring apparatus includes a support loop having strain gages mounted thereon and a drag means which is attached to one end of the support loop and which bends the sides of the support loop and induces strains in the strain gages when a flow stream impacts thereon.

  12. Gravimetric quantitative determination of packaging residues in feed from former food.

    Science.gov (United States)

    Amato, Giuseppina; Desiato, Rosanna; Giovannini, Tiziana; Pinotti, Luciano; Tretola, Marco; Gili, Marilena; Marchis, Daniela

    2017-08-01

    Valorisation of former foodstuff products (FFP) in feed is part of a long-term strategy for sustainability. An approach to valorise FFP outside the waste value chain is their use as an alternative source of feed materials, with a subsequent optimisation of the environmental impact of products. In the current practice of food production, food packaging is provided to ensure the maintenance of food quality and safety during transport and storage. One of the problems of reusing FFP is how to deal with packaging materials or remains that can become residues in the feed. The aim of this study is to propose a fast and sensitive gravimetric method, fit for routine official controls, for the determination of packaging residues in feed. The developed method can briefly be summarised as: (1) visual selection of the undesired ingredients which can be identified as remnants of packaging materials; (2) weighing of the selected materials; (3) defatting; (4) dehydration; (5) final weighing; and (6) reporting of weight and percentage. Moreover, the method has been validated through the determination of some of the parameters listed in Council Regulation 2004/882/EC (i.e., specificity, limit of quantification (LOQ), recovery, repeatability, within-laboratory reproducibility and measurement uncertainty).

  13. An accelerated exposure and testing apparatus for building joint sealants.

    Science.gov (United States)

    White, C C; Hunston, D L; Tan, K T; Hettenhouser, J; Garver, J D

    2013-09-01

    The design, fabrication, and implementation of a computer-controlled exposure and testing apparatus for building joint sealants are described in this paper. This apparatus is unique in its ability to independently control and monitor temperature, relative humidity, ultraviolet (UV) radiation, and mechanical deformation. Each of these environmental factors can be controlled precisely over a wide range of conditions during periods of a month or more. Moreover, as controlled mechanical deformations can be generated, in situ mechanical characterization tests can be performed without removing specimens from the chamber. Temperature and humidity were controlled during our experiments via a precision temperature regulator and proportional mixing of dry and moisture-saturated air; while highly uniform UV radiation was attained by attaching the chamber to an integrating sphere-based radiation source. A computer-controlled stepper motor and a transmission system were used to provide precise movement control. The reliability and effectiveness of the apparatus were demonstrated on a model sealant material. The results clearly show that this apparatus provides an excellent platform to study the long-term durability of building joint sealants.

  14. Neutron logging reliability techniques and apparatus

    International Nuclear Information System (INIS)

    Johnstone, C.W.

    1975-01-01

    Apparatus and methods for verifying the validity of data derived at least in part by neutron logging of earth formations, and, where indicated, for affording neutron diffusion-corrected values of such data, are disclosed. (WHK)

  15. Apparatus for feeding nuclear fuel pellets to a loading tray

    International Nuclear Information System (INIS)

    Huggins, T.B.

    1979-01-01

    Apparatus for feeding nuclear fuel pellets at a uniform predetermined rate between pellet centering and grinding apparatus and a tray for loading pellets into nuclear fuel rod. Pellets discharged from the grinding apparatus are conveyed by a belt to a drive wheel forcing the pellets in engagement with the belt. The pellets under the drive wheel are capable of pushing a line of about 36 pellets onto a pellet dumping mechanism. As the dumping mechanism is actuated to dump the pellets on to a loading tray, the pellets moving toward the mechanism are stopped and the drive wheel is simultaneously lifted off the pellets until the pellet dumping process is completed. (U.K.)

  16. Characterization of the structure of the Salar de Atacama Basin through gravimetric profiles and interval velocity analysis.

    Science.gov (United States)

    Becerra, J.; Bascunan, S. A.; Maksymowicz, A.; Martínez, F.; Arriagada, C.

    2017-12-01

    The structure of the basins found in the Preandean Depression in the northern Central Andes has remained elusive, partly due to a poor understanding of the structural styles and stratigraphy beneath their surface. An independent approach to the multiple interpretations of seismic lines available is the analysis of 2D gravity profiles. An E-W profile was performed across the basin, closely matching the surficial trace of previous seismic lines. The profile shows three gravimetric lows, the most relevant being one beneath the Llano de la Paciencia- Cordillera de la Sal, comprised of deformed evaporitic and terrigenous deposits of Oligocene-Early Miocene age. The structure which bounds this gravity low has a steeper dip on its eastern side, bounding the eastern side of the Cordillera de la Sal, which is at odds with previous studies that interpreted its western contact with Cretaceous outcrops as the possible basin boundary. The 3-D analyses of seismic interval velocity data around the gravimetric survey reveal a major vertical contrast in the eastern portion of the profile, interpreted as the bottom of the evaporite successions, followed to the west by a complex, narrow and deep zone of low velocities. Westward, the Cretaceous rocks record higher velocities than its post-Paleocene counterparts, and an almost uniform increase in velocity with depth. The major gravity anomaly is closely related to the Cordillera de la Sal, which consists of an array of folds and reverse faults involving Oligocene to recent deposits. We propose that the faults which generated Oligocene extension are not at the western border of the basin, but around the Cordillera de la Sal, which is the result of Miocene inversion of the same system. Strike-slip deformation was also probably a major contributor in basin formation, as shown by the narrow yet deep shape of the depocenter.

  17. Development of an experimental apparatus for nucleate boiling analysis

    International Nuclear Information System (INIS)

    Castro, A.J.A. de.

    1984-01-01

    An experimental apparatus is developed for the study of the parameters that affect nucleate boiling. The experimental set up is tested for nucleate boiling in an annular test section with subcooled water flow. The following parameters are analysed: pressure, fluid velocity and the fluid temperature at the test section entrance. The performance of the experimental apparatus is analysed by the results and by the problems raised by the operation of the setup. (Author) [pt

  18. Radiator debris removing apparatus and work machine using same

    Science.gov (United States)

    Martin, Kevin L [Washburn, IL; Elliott, Dwight E [Chillicothe, IL

    2008-09-02

    A radiator assembly includes a finned radiator core and a debris removing apparatus having a compressed air inlet and at least one compressed air outlet configured to direct compressed air through the radiator core. A work machine such as a wheel loader includes a radiator and a debris removing apparatus coupled with on-board compressed air and having at least one pressurized gas outlet configured to direct a gas toward the face of the radiator.

  19. Isopiestic Determination of the Osmotic and Activity Coefficients of Li2SO4(aq) at T=298.15 and 323.15 K, and Representation with an Extended Ion-Interaction (Pitzer) Model

    Energy Technology Data Exchange (ETDEWEB)

    Rard, Joseph A. [Lawrence Livermore National Laboratory (LLNL); Clegg, Simon L. [University of East Anglia, Norwich, United Kingdom; Palmer, Donald [ORNL

    2007-01-01

    Isopiestic vapor-pressure measurements were made for Li{sub 2}SO{sub 4}(aq) from 0.1069 to 2.8190 mol{center_dot}kg{sup -1} at 298.15 K, and from 0.1148 to 2.7969 mol{center_dot}kg{sup -1} at 323.15 K, with NaCl(aq) as the reference standard. Published thermodynamic data for this system were reviewed, recalculated for consistency, and critically assessed. The present results and the more reliable published results were used to evaluate the parameters of an extended version of Pitzer's ion-interaction model with an ionic-strength dependent third-virial coefficient, as well as those of the standard Pitzer model, for the osmotic and activity coefficients at both temperatures. Published enthalpies of dilution at 298.15 K were also analyzed to yield the parameters of the ion-interaction models for the relative apparent molar enthalpies of dilution. The resulting models at 298.15 K are valid to the saturated solution molality of the thermodynamically stable phase Li{sub 2}SO{sub 4}{center_dot}H{sub 2}O(cr). Solubilities of Li{sub 2}SO{sub 4}{center_dot}H{sub 2}O(cr) at 298.15 K were assessed and the selected value of m(sat.)=3.13{+-}0.04 mol{center_dot}kg{sup -1} was used to evaluate the thermodynamic solubility product K {sub s}(Li{sub 2}SO{sub 4}{center_dot}H{sub 2}O, cr, 298.15 K) = (2.62{+-}0.19) and a CODATA-compatible standard molar Gibbs energy of formation {Delta}{sub f} G m{sup 0}(Li{sub 2}SO{sub 4}{center_dot}H{sub 2}O, cr, 298.15 K) = -(1564.6{+-}0.5) kJ{center_dot}mol{sup -1}.

  20. Exposing the Film Apparatus: The Film Archive as a Research Laboratory

    NARCIS (Netherlands)

    Fossati, G.; van den Oever, A.

    2016-01-01

    Imagine opening the gates to a vault full of media apparatuses and letting loose thirty-two international media scholars and professionals on its heterogeneous content... Exposing the Film Apparatus collects the results of such an experiment. This book addresses the keen awareness of the prominence

  1. Thickness measuring apparatus and method for tire ply and similar materials

    International Nuclear Information System (INIS)

    Cho, B.Y.; Utt, O.L.

    1978-01-01

    The invention relates to method and apparatus for measuring the amount of material on opposite sides of the reinforcing cord of a tire ply, and more particularly relates to a backscatter X-ray radiation gauging apparatus and method for obtaining the aforesaid measurements. (author)

  2. A Small-Scale and Low-Cost Apparatus for the Electrolysis of Water

    Science.gov (United States)

    Eggeen, Per-Odd; Kvittingen, Lise

    2004-01-01

    The construction of two simple, inexpensive apparatuses that clearly show the electrolysis of water are described. Traditionally the electrolysis of water is conducted in a Hofmann apparatus which is expensive and fragile.

  3. Determinations of total residue, total oxide and density of high-level liquid waste (HLLW) by gravimetric method

    International Nuclear Information System (INIS)

    Li Yun; Gao Yueying; Yang Ming; Jin Liyun

    1992-01-01

    Gravimetric method for determination of total residue, total oxide and density of HLLW is developed. An aliquot of the original HLLW solution is piped on to the small quartz disc and put into the mini muffle furnace carefully. It is first heated to below 100 degree C (for 1.5 hours to remove the free water, and then heated to 180 degree C for 2 hours to remove the crystal water in a furnace. The total residue is weighed at room temperature. The precision is better than 3% for the determination of total residue and total oxide. An aliquot of the original HLLW solution is piped into the weighing bottle and weighed. The precision is better than 1%

  4. Correlating molecular phylogeny with venom apparatus occurrence in Panamic auger snails (Terebridae.

    Directory of Open Access Journals (Sweden)

    Mandë Holford

    2009-11-01

    Full Text Available Central to the discovery of neuroactive compounds produced by predatory marine snails of the superfamily Conoidea (cone snails, terebrids, and turrids is identifying those species with a venom apparatus. Previous analyses of western Pacific terebrid specimens has shown that some Terebridae groups have secondarily lost their venom apparatus. In order to efficiently characterize terebrid toxins, it is essential to devise a key for identifying which species have a venom apparatus. The findings presented here integrate molecular phylogeny and the evolution of character traits to infer the presence or absence of the venom apparatus in the Terebridae. Using a combined dataset of 156 western and 33 eastern Pacific terebrid samples, a phylogenetic tree was constructed based on analyses of 16S, COI and 12S mitochondrial genes. The 33 eastern Pacific specimens analyzed represent four different species: Acus strigatus, Terebra argyosia, T. ornata, and T. cf. formosa. Anatomical analysis was congruent with molecular characters, confirming that species included in the clade Acus do not have a venom apparatus, while those in the clade Terebra do. Discovery of the association between terebrid molecular phylogeny and the occurrence of a venom apparatus provides a useful tool for effectively identifying the terebrid lineages that may be investigated for novel pharmacological active neurotoxins, enhancing conservation of this important resource, while providing supplementary information towards understanding terebrid evolutionary diversification.

  5. Tannins gravimetric yield condensed in Anadenanthera peregrina bark in different diameter classes

    Directory of Open Access Journals (Sweden)

    Caroline Junqueira Sartori

    2014-06-01

    Full Text Available This work aimed to determine the gravimetric yield of condensed tannins in the Anadenanthera peregrina bark in different diameter classes. Fifty-nine trees samples were collected of Anadenanthera peregrina, at 1.30m of the ground (diameter at breast height - DBH, distributed in seven diameter classes. The barks were dried and crushed in mill of hammer. Composite sample was made to prepare the extract. The extraction was done using water in the ratio 15:1 (v/w, added 3% sodium sulfite (w/w in water-bath at 70°C for 4 hours. The material was filtered using fine cloth strainer and concentrated on a heating plate at approximately 150 g. It was determined the extract mass and removed 10 g for obtaining solids content and 20g for the Stiasny's index. The average values of total solids content, Stiasny's index, condensed tannin content and the compound content non-tannin were 11.34%; 75.79%; 12.76% and 4.07%, respectively. The content of solids, Stiasny's index, compound content non-tannin show significant differences between diameter classes. For the condensed tannins production, the diameter class parameter there was no influence.

  6. Simulation of the kinetics of enzymic hydrolysis of starch in standard apparatus used in alcohol production

    Energy Technology Data Exchange (ETDEWEB)

    Rovinskii, L A; Yarovenko, V L

    1977-01-01

    A mathematical model is described for kinetics of enzymic hydrolysis of starch in standard apparatus used in alcohol fermentation. The apparatus with uniform mixing and displacement was highly superior compared with other apparatuses. Differences of temperature with the apparatus significantly affects the rate of starch hydrolysis compared with constant temperature.

  7. Active magnetic regenerator method and apparatus

    Science.gov (United States)

    DeGregoria, Anthony J.; Zimm, Carl B.; Janda, Dennis J.; Lubasz, Richard A.; Jastrab, Alexander G.; Johnson, Joseph W.; Ludeman, Evan M.

    1993-01-01

    In an active magnetic regenerator apparatus having a regenerator bed of material exhibiting the magnetocaloric effect, flow of heat transfer fluid through the bed is unbalanced, so that more fluid flows through the bed from the hot side of the bed to the cold side than from the cold side to the hot side. The excess heat transfer fluid is diverted back to the hot side of the bed. The diverted fluid may be passed through a heat exchanger to draw heat from a fluid to be cooled. The apparatus may be operated at cryogenic temperatures, and the heat transfer fluid may be helium gas and the fluid to be cooled may be hydrogen gas, which is liquified by the device. The apparatus can be formed in multiple stages to allow a greater span of cooling temperatures than a single stage, and each stage may be comprised of two bed parts. Where two bed parts are employed in each stage, a portion of the fluid passing from the hot side to the cold side of a first bed part which does not have a magnetic field applied thereto is diverted back to the cold side of the other bed part in the stage, where it is passed through to the hot side. The remainder of the fluid from the cold side of the bed part of the first stage is passed to the hot side of the bed part of the second stage.

  8. Thermoforming apparatus

    International Nuclear Information System (INIS)

    Wallsten, H.I.

    1984-01-01

    Apparatus for manufacturing articles is disclosed in which a preheated sheet of thermoplastic material is intermittently fed to present successive preheated portions of the sheet in a work station having a forming tool for forming articles in each successive sheet portion and a stamping tool for co-operating with the forming tool to stamp the formed articles from the sheet. The forming tool has a plurality of forming dies which are movable successively and cyclically into the work station for forming articles in respective successive sheet portions. After each forming operation the stamping tool is brought into engagement with a resilient counter-surface on the forming die to stamp from the sheet the articles formed by that die

  9. Nuclear propulsion apparatus with alternate reactor segments

    International Nuclear Information System (INIS)

    Szekely, T.

    1979-01-01

    Nuclear propulsion apparatus comprising: (a) means for compressing incoming air; (b) nuclear fission reactor means for heating said air; (c) means for expanding a portion of the heated air to drive said compressing means; (d) said nuclear fission reactor means being divided into a plurality of radially extending segments; (e) means for directing a portion of the compressed air for heating through alternate segments of said reactor means and another portion of the compressed air for heating through the remaining segments of said reactor means; and (f) means for further expanding the heated air from said drive means and the remaining heated air from said reactor means through nozzle means to effect reactive thrust on said apparatus. 12 claims

  10. Apparatus and method for radioactive waste screening

    Science.gov (United States)

    Akers, Douglas W.; Roybal, Lyle G.; Salomon, Hopi; Williams, Charles Leroy

    2012-09-04

    An apparatus and method relating to screening radioactive waste are disclosed for ensuring that at least one calculated parameter for the measurement data of a sample falls within a range between an upper limit and a lower limit prior to the sample being packaged for disposal. The apparatus includes a radiation detector configured for detecting radioactivity and radionuclide content of the of the sample of radioactive waste and generating measurement data in response thereto, and a collimator including at least one aperture to direct a field of view of the radiation detector. The method includes measuring a radioactive content of a sample, and calculating one or more parameters from the radioactive content of the sample.

  11. Apparatus for measuring a concentration of radioactivity

    International Nuclear Information System (INIS)

    Tabuchi, H.; Ogushi, A.

    1978-01-01

    Disclosed is an apparatus for measuring concentration of radioactivity in a fluid circulating in a cooling system or a disposal system, etc., of a nuclear power plant (e.g. coolant), the apparatus having a plurality of sampling tubes with different diameters depending on the intensities of radioactivity, and the sampling tubes having valves for switching from one fluid to another fluid. The sampling tubes are connected to the system to a discharge pipe, and are disposed in the proximity of a radiation detector adapted to issue a signal representative of radiation. The issued signal is supplied to a multichannel pulse height analyzer and a data processing system providing an indication of the concentrations of radioactivities for respective radionuclides

  12. Apparatus and method for treating waste material

    International Nuclear Information System (INIS)

    Allison, W.

    1981-01-01

    Apparatus is described for the packaging of waste material in a vessel, comprising: a vessel entry station having inlet and outlet doors; a filling station downstream of the vessel entry station and having a filling position to which vessels are transferred from the entry station through the outlet door, the filling station having filling means for introducing radioactive waste into the vessel; a mixing station having a mixing position to which a vessel is transferred from the filling position; a capping station having a capping position to which a vessel is transferred from the mixing position; and means for effecting transfer of a vessel through the apparatus. Radiation shielding is provided. (U.K.)

  13. Wave disc engine apparatus

    Energy Technology Data Exchange (ETDEWEB)

    Muller, Norbert; Piechna, Janusz; Sun, Guangwei; Parraga, Pablo-Francisco

    2018-01-02

    A wave disc engine apparatus is provided. A further aspect employs a constricted nozzle in a wave rotor channel. A further aspect provides a sharp bend between an inlet and an outlet in a fluid pathway of a wave rotor, with the bend being spaced away from a peripheral edge of the wave rotor. A radial wave rotor for generating electricity in an automotive vehicle is disclosed in yet another aspect.

  14. Thermal power measurement apparatus

    International Nuclear Information System (INIS)

    1981-01-01

    Thermal power measurements are important in nuclear power plants, fossil-fuel plants and other closed loop systems such as heat exchangers and chemical reactors. The main object of this invention is to determine the enthalpy of a fluid using only acoustically determined sound speed and correlating the speed with enthalpy. An enthalpy change is measured between two points in the fluid flow: the apparatus is described in detail. (U.K.)

  15. X-ray apparatus

    International Nuclear Information System (INIS)

    Grady, J.K.

    1985-01-01

    X-ray apparatus is described which has a shutter between the X-ray source and the patient. The shutter controls the level of radiation to which the patient is exposed instead of merely discontinuing the electric power supplied to the source. When the shutter is opened a radiation sensor senses the level of X-radiation. When a preset quantity of X-radiation has been measured an exposure control closes the shutter. Instead of using the radiation sensor, the integrated power supplied to the anode of the X-ray source may be measured. (author)

  16. Remote docking apparatus

    International Nuclear Information System (INIS)

    Dent, T.H.; Sumpman, W.C.; Wilhelm, J.J.

    1981-01-01

    The remote docking apparatus comprises a support plate with locking devices mounted thereon. The locking devices are capable of being inserted into tubular members for suspending the support plate therefrom. A vertical member is attached to the support plate with an attachment mechanism attached to the vertical member. A remote access manipulator is capable of being attached to the attachment mechanism so that the vertical member can position the remote access manipulator so that the remote access manipulator can be initially attached to the tubular members in a well defined manner

  17. Combined Gravimetric-Seismic Crustal Model for Antarctica

    Science.gov (United States)

    Baranov, Alexey; Tenzer, Robert; Bagherbandi, Mohammad

    2018-01-01

    -28 km), while in West Antarctica the Moho depth minima are along the West Antarctic Rift System under the Bentley depression (20-22 km) and Ross Sea Ice Shelf (16-24 km). The gravimetric result confirmed a maximum extension of the Antarctic continental margins under the Ross Sea Embayment and the Weddell Sea Embayment with an extremely thin continental crust (10-20 km).

  18. Kinematic X-Ray Analysis Apparatus

    NARCIS (Netherlands)

    Koningsberger, D.C.; Brinkgreve, P.

    1983-01-01

    In an X-ray analysis apparatus, a moving mechanism is provided by a main guide member along which a main slide device can be displaced. Rotatably connected with the main slide device is a detector guide member along which a detection slide device is displaced. The main slide device, as well as the

  19. Induction apparatus monitoring structural strains in liquid-metal-cooled nuclear reactor

    International Nuclear Information System (INIS)

    Dean, S.A.; Evans, R.A.

    1981-01-01

    An improved method of monitoring induced torsional and linear strains in the internal structures of liquid metal cooled nuclear reactors is described. An electrical induction apparatus indicates the variation of magnetic coupling caused by a ferromagnetic member of the apparatus being subjected to such strains. (U.K.)

  20. Apparatus and method for stabilization or oxidation of polymeric materials

    Science.gov (United States)

    Paulauskas, Felix L [Knoxville, TN; Sherman, Daniel M [Knoxville, TN

    2010-01-19

    An apparatus for treating polymeric materials comprises a treatment chamber adapted to maintain a selected atmosphere at a selected temperature; a means for supporting the polymeric material within the chamber; and, a source of ozone-containing gas, which decomposes at the selected temperature yielding at least one reactive oxidative species whereby the polymer is stabilized and cross linked through exposure to the oxidative species in the chamber at the selected temperature. The ozone may be generated by a plasma discharge or by various chemical processes. The apparatus may be configured for either batch-type or continuous-type processing. The apparatus and method are especially useful for preparing polymer fibers, particularly PAN fibers, for later carbonization treatments as well as to make flame-retardant fabrics.

  1. Maintenance and control of apparatus for radiotherapy

    International Nuclear Information System (INIS)

    Wakui, Sho

    1979-01-01

    In order to perform the safe operation of radiotherapy apparatuses and to secure the accuracy in positioning patients and in setting up radiation beam, proper checking-up and maintenance schedule is necessary. Such schedule is described briefly and also the mechanical or electrical equipments designed for securing the safety and accuracy or eliminating in adequate operation are explained, especially on treatment tables and accessories, such as wedge filters, irradiation field indicators and pointers, and the devices for observing patients. The structures and the practical control of the following equipments are explained; standard treatment table, treatment table with a lifting column by oil pressure, mobile positioning control pedestal, positioning control pendaut, mechanical fuse cutter for the safeguard of table height movement, safety interlock to protect table from physical contact with radiation head in rotation and safeguard for arms of a patient in longitudinal movement of treatment table. For the maintenance and control of wedge filters, the kind of filter angle in use, the direction of filter in use and whether filter is used or not are exactly confirmed by adequate display. The direction mechanism of radiation field and the pointers are required to be strict for exact focusing of radiation. Various control apparatuses and monitoring apparatuses are described. (Kobatake, H.)

  2. The geothermal gradient map of Central Tunisia: Comparison with structural, gravimetric and petroleum data

    Science.gov (United States)

    Dhia, Hamed Ben

    1987-10-01

    Five hundred and fifty temperature values, initially measured as either bottom-hole temperatures (BHT) or drill-stem tests (DST), from 98 selected petroleum exploration wells form the basis of a geothermal gradient map of central Tunisia. A "global-statistical" method was employed to correct the BHT measurements, using the DST as references. The geothermal gradient ranges from 23° to 49°C/km. Comparison of the geothermal gradient with structural, gravimetric and petroleum data indicates that: (1) the general trend of the geothermal gradient curves reflects the main structural directions of the region, (2) zones of low and high geothermal gradient are correlated with zones of negative and positive Bouguer anomalies and (3) the five most important oil fields of central Tunisia are located near the geothermal gradient curve of 40° C/km. Such associations could have practical importance in petroleum exploration, but their significance must first be established through further investigation and additional data.

  3. An apparatus for a complimentary treatment of spasmodic torticollis.

    Science.gov (United States)

    Saito, I; Weiss, T

    1988-07-01

    We have developed an apparatus for treating spasmodic torticollis that can be used at home both during intensive therapy and follow-up. The refractoriness of spasmodic torticollis requires patients to practice biofeedback training partly on a home basis. However, it is usually difficult for spasmodic torticollis patients to provide and handle electromyographic (EMG) biofeedback training instruments. The present apparatus has 2 parts: first, a harness with a light source which is fixed on both shoulders; second, a photoreceptor, operant system for rewarding effect, and a digital recorder. The light is adjusted to strike the photoreceptor on the forehead when headposition is normal. Subjects are asked to keep the operant system--e.g. a radio--activated. They are trained in various postures as sitting, standing and walking. This apparatus provides a chance of home training to augment and maintain the effect during therapeutic sessions and the follow-up period.

  4. Assessment of disintegration of rapidly disintegrating tablets by a visiometric liquid jet-mediated disintegration apparatus.

    Science.gov (United States)

    Desai, Parind M; Liew, Celine V; Heng, Paul W S

    2013-02-14

    The aim of this study was to develop a responsive disintegration test apparatus that is particularly suitable for rapidly disintegrating tablets (RDTs). The designed RDT disintegration apparatus consisted of disintegration compartment, stereomicroscope and high speed video camera. Computational fluid dynamics (CFD) was used to simulate 3 different designs of the compartment and to predict velocity and pressure patterns inside the compartment. The CFD preprocessor established the compartment models and the CFD solver determined the numerical solutions of the governing equations that described disintegration medium flow. Simulation was validated by good agreement between CFD and experimental results. Based on the results, the most suitable disintegration compartment was selected. Six types of commercial RDTs were used and disintegration times of these tablets were determined using the designed RDT disintegration apparatus and the USP disintegration apparatus. The results obtained using the designed apparatus correlated well to those obtained by the USP apparatus. Thus, the applied CFD approach had the potential to predict the fluid hydrodynamics for the design of optimal disintegration apparatus. The designed visiometric liquid jet-mediated disintegration apparatus for RDT provided efficient and precise determination of very short disintegration times of rapidly disintegrating dosage forms. Copyright © 2012 Elsevier B.V. All rights reserved.

  5. Apparatus for combining oxygen and hydrogen

    International Nuclear Information System (INIS)

    Betz, E.C.

    1977-01-01

    An apparatus is described for catalytically combining hydrogen and oxygen which includes two concentric catalyst chambers arranged so that the outer chamber surrounds the inner chamber and the gas stream passes radially through the outer catalyst chamber. 10 claims, 2 figures

  6. Apparatus for fuel replacement

    International Nuclear Information System (INIS)

    Imada, Takahiko.

    1974-01-01

    Object: To support a telescope mast such that no deforming load is applied to it even during massive vibration, it is held fixed at the time of fuel replacement to permit satisfactory remote control operation by automatic operation. Structure: The body of the fuel replacement apparatus is provided with telescope mast fixing means comprising a slide base supported for reciprocal movement with respect to a telescope mast, an operating arm pivoted at the slide base, a wrist member mounted on the free end of the operating arm and an engagement member for restricting the slide base and operating arm at the time of loading and unloading the fuel. When loading and unloading the fuel, the slide base and operating arm are restrained by the engagement member to reliably restrict the vibration of the telescope mast. When the fuel replacement apparatus is moved, the means provided on the operating arm is smoothly displaced to follow the swing (vibration) of the telescope mast to prevent the deforming load from being applied to the support portion or other areas. The wrist member supports the telescope mast such that it can be rotated while restraining movement in the axial direction, and it is provided with revolution drive means for rotating the telescope mast under remote control. (Kamimura, M.)

  7. Apparatus to detect stable fractional charges on matter

    International Nuclear Information System (INIS)

    Vanderspek, R.

    1980-04-01

    The construction of an apparatus designed to detect stable fractional charges on matter, if they exist, to the level of 10 -24 per nucleon is reported and discussed. The charges on a stream of highly consistent droplets produced by the apparatus are determined by accurate measurement of the deflection of the droplets in falling through a static electric field. Maintenance of certain parameters of operation calculated to limit the random effects of electrical and aerodynamical disturbances on the droplets indicate a precision in the measurement of the charge on a droplet of 0.02e can be attained. 7 figures

  8. Apparatus for use in radioimmunoassays

    International Nuclear Information System (INIS)

    Chen, C-H.; Tsay, H-M.; Heyer, R.E.

    1979-01-01

    Apparatus for solid-phase antibody separation techniques used in radioimmunoassays is described in this invention. It consists of a rectangular prism tray with multiple wells protruding into its interior from one side. Near the base of the tray is an orifice used for creating evacuated condition within the structure. At the base of each well there is an orifice of such size and shape as to retain an aqueous liquid under given pressure conditions but permit the evacuation of this liquid at reduced pressure. The outlet of these orifices is in the shape of an inverted conical frustrum. Each of the wells contains an antibody coated disc of porous cellulose paper surrounded by a plastic support. The porous nature of the cellulose paper ensures contact between the antibody coating and the antigen. The use of antibody coated porous cellulose paper in combination with the vacuum operated apparatus simplifies the manipulative steps whilst still maintaining the sensitivity of the radioimmunoassay. It also obviates the need for aspiration and thus lessens the risk of contamination from one sample to another. (UK)

  9. Apparatus for incinerating hazardous waste

    Science.gov (United States)

    Chang, R.C.W.

    1994-12-20

    An apparatus is described for incinerating wastes, including an incinerator having a combustion chamber, a fluid-tight shell enclosing the combustion chamber, an afterburner, an off-gas particulate removal system and an emergency off-gas cooling system. The region between the inner surface of the shell and the outer surface of the combustion chamber forms a cavity. Air is supplied to the cavity and heated as it passes over the outer surface of the combustion chamber. Heated air is drawn from the cavity and mixed with fuel for input into the combustion chamber. The pressure in the cavity is maintained at least approximately 2.5 cm WC higher than the pressure in the combustion chamber. Gases cannot leak from the combustion chamber since the pressure outside the chamber (inside the cavity) is higher than the pressure inside the chamber. The apparatus can be used to treat any combustible wastes, including biological wastes, toxic materials, low level radioactive wastes, and mixed hazardous and low level transuranic wastes. 1 figure.

  10. BETA (Bitter Electromagnet Testing Apparatus)

    Science.gov (United States)

    Bates, Evan M.; Birmingham, William J.; Rivera, William F.; Romero-Talamas, Carlos A.

    2017-10-01

    The Bitter Electromagnet Testing Apparatus (BETA) is a 1-Tesla (T) prototype of the 10-T Adjustable Long Pulse High-Field Apparatus (ALPHA). These water-cooled resistive magnets use high DC currents to produce strong uniform magnetic fields. Presented here is the successful completion of the BETA project and experimental results validating analytical magnet designing methods developed at the Dusty Plasma Laboratory (DPL). BETA's final design specifications will be highlighted which include electromagnetic, thermal and stress analyses. The magnet core design will be explained which include: Bitter Arcs, helix starters, and clamping annuli. The final version of the magnet's vessel and cooling system are also presented, as well as the electrical system of BETA, which is composed of a unique solid-state breaker circuit. Experimental results presented will show the operation of BETA at 1 T. The results are compared to both analytical design methods and finite element analysis calculations. We also explore the steady state maximums and theoretical limits of BETA's design. The completion of BETA validates the design and manufacturing techniques that will be used in the succeeding magnet, ALPHA.

  11. 46 CFR 28.205 - Fireman's outfits and self-contained breathing apparatus.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 1 2010-10-01 2010-10-01 false Fireman's outfits and self-contained breathing apparatus... the Boundary Lines or With More Than 16 Individuals On Board, or for Fish Tender Vessels Engaged in the Aleutian Trade § 28.205 Fireman's outfits and self-contained breathing apparatus. (a) Each vessel...

  12. Apparatus, System, and Method for Forward Osmosis in Water Reuse

    KAUST Repository

    Yangali-Quintanilla, Victor

    2013-01-03

    An apparatus, system, and method for desalinating water is presented. The invention relates to recovery of water from impaired water sources by using FO and seawater as draw solution (DS). The seawater becomes diluted over time and can be easily desalinated at very low pressures. Thus, a device consumes less energy when recovering water. The apparatus, system and method comprise an immersed forward osmosis cell.

  13. Multicusp plasma containment apparatus

    International Nuclear Information System (INIS)

    Limpaecher, R.

    1980-01-01

    It has been discovered that plasma containment by a chamber having multi-pole magnetic cusp reflecting walls in combination with electronic injection for electrostatic containment provides the means for generating magnetic field free quiescent plasmas for practical application in ion-pumps, electronic switches, and the like. 1250 ''alnico v'' magnets 1/2 '' X 1/2 '' X 1 1/2 '' provide containment in one embodiment. Electromagnets embodying toroidal funneling extend the principle to fusion apparatus

  14. Study on blood compatibility of the radiation sterilized disposable burette transfusion apparatus

    International Nuclear Information System (INIS)

    Chen Guochong; Liu Wen; Liu Qingfang

    2011-01-01

    The blood compatibility of the radiation sterilized disposable burette transfusion apparatus was investigated to provide evidence for the safety of radiation sterilized medical devices. The initial bacteria burden of the disposable burette transfusion apparatus was examined according to the ISO11737 standard, and the whole blood clotting time, prothrombin time, partial thromboplastin time and hemolysis rate of the samples were determined. There was no significant difference between the radiation sterilized samples and negative controls on WBCT, PT and PTT (p>0.05). Haemolysis test showed that the haemolysis rate of the sample sterilized by irradiation was 1.38%, which was coincidence with the criteria of the medical devices. After sterilization by irradiation, disposable burette transfusion apparatus show good blood compatibility, which could be considered that radiation sterilization is a biologically safe method for the medical apparatus. (authors)

  15. Object Tracking Vision System for Mapping the UCN τ Apparatus Volume

    Science.gov (United States)

    Lumb, Rowan; UCNtau Collaboration

    2016-09-01

    The UCN τ collaboration has an immediate goal to measure the lifetime of the free neutron to within 0.1%, i.e. about 1 s. The UCN τ apparatus is a magneto-gravitational ``bottle'' system. This system holds low energy, or ultracold, neutrons in the apparatus with the constraint of gravity, and keeps these low energy neutrons from interacting with the bottle via a strong 1 T surface magnetic field created by a bowl-shaped array of permanent magnets. The apparatus is wrapped with energized coils to supply a magnetic field throughout the ''bottle'' volume to prevent depolarization of the neutrons. An object-tracking stereo-vision system will be presented that precisely tracks a Hall probe and allows a mapping of the magnetic field throughout the volume of the UCN τ bottle. The stereo-vision system utilizes two cameras and open source openCV software to track an object's 3-d position in space in real time. The desired resolution is +/-1 mm resolution along each axis. The vision system is being used as part of an even larger system to map the magnetic field of the UCN τ apparatus and expose any possible systematic effects due to field cancellation or low field points which could allow neutrons to depolarize and possibly escape from the apparatus undetected. Tennessee Technological University.

  16. Method and apparatus for dismantling and disposing of fuel assemblies

    International Nuclear Information System (INIS)

    Meuschke, R.E.; Schulties, J.R.

    1985-01-01

    This invention relates to apparatus and a method for dismantling, shearing, and compacting a fuel assembly frame skeleton. It uses an apparatus capable of hanging or being supported in the transfer canal of the spent fuel pit of the fuel handling building. This apparatus includes a bottom nozzle shear which is held under water to shear off the bottom nozzle and convey it to a scrap transfer bin. Then the remaining portion is brought to a skeleton compactor and shear, also held under water. The compacted skeleton is sheared into a number of smaller portions. After compacting and shearing, the individual portions are fed to the scrap transfer bin. The compacted and sheared skeleton assembly may be placed into a container that is adapted to hold four skeletons for off-site removal

  17. Apparatus and method for oxidation and stabilization of polymeric materials

    Science.gov (United States)

    Paulauskas, Felix L [Knoxville, TN; White, Terry L [Knoxville, TN; Sherman, Daniel M [Knoxville, TN

    2009-05-19

    An apparatus for treating polymeric materials comprises a treatment chamber adapted to maintain a selected atmosphere; a means for supporting the polymeric material within the chamber; and, a source of plasma-derived gas containing at least one reactive oxidative species whereby the polymer is stabilized and cross linked through exposure to the oxidative species in the chamber at a selected temperature. The polymer may be directly exposed to the plasma, or alternatively, the plasma may be established in a separate volume from which the reactive species may be extracted and introduced into the vicinity of the polymer. The apparatus may be configured for either batch-type or continuous-type processing. The apparatus and method are especially useful for preparing polymer fibers, particularly PAN fibers, for later carbonization treatments.

  18. Therapeutic radiation apparatus having an optical pointer

    International Nuclear Information System (INIS)

    1981-01-01

    This patent specification relates to a therapeutic irradiating apparatus including a radiation source arranged to provide a beam of penetrating radiation and an optical alignment indicator comprising at least two light sources each provided with means to provide a planar divergent beam of light located so that at least two light beams intersect along a line substantially coincident with the central axis of the path of the radiation beam. The claim relates to cylindrical lenses providing the means of providing the divergent beams, and to lasers as the light sources. Claims are also made for the apparatus providing means of supporting and aligning the patient, and for disposing the light sources so that the exit point of the radiation beam is illuminated. (U.K.)

  19. Data structures and apparatuses for representing knowledge

    Science.gov (United States)

    Hohimer, Ryan E; Thomson, Judi R; Harvey, William J; Paulson, Patrick R; Whiting, Mark A; Tratz, Stephen C; Chappell, Alan R; Butner, Robert S

    2014-02-18

    Data structures and apparatuses to represent knowledge are disclosed. The processes can comprise labeling elements in a knowledge signature according to concepts in an ontology and populating the elements with confidence values. The data structures can comprise knowledge signatures stored on computer-readable media. The knowledge signatures comprise a matrix structure having elements labeled according to concepts in an ontology, wherein the value of the element represents a confidence that the concept is present in an information space. The apparatus can comprise a knowledge representation unit having at least one ontology stored on a computer-readable medium, at least one data-receiving device, and a processor configured to generate knowledge signatures by comparing datasets obtained by the data-receiving devices to the ontologies.

  20. Apparatus for monitoring two-phase flow

    Science.gov (United States)

    Sheppard, John D.; Tong, Long S.

    1977-03-01

    A method and apparatus for monitoring two-phase flow is provided that is particularly related to the monitoring of transient two-phase (liquid-vapor) flow rates such as may occur during a pressurized water reactor core blow-down. The present invention essentially comprises the use of flanged wire screens or similar devices, such as perforated plates, to produce certain desirable effects in the flow regime for monitoring purposes. One desirable effect is a measurable and reproducible pressure drop across the screen. The pressure drop can be characterized for various known flow rates and then used to monitor nonhomogeneous flow regimes. Another useful effect of the use of screens or plates in nonhomogeneous flow is that such apparatus tends to create a uniformly dispersed flow regime in the immediate downstream vicinity. This is a desirable effect because it usually increases the accuracy of flow rate measurements determined by conventional methods.

  1. Light Emitting, Photovoltaic or Other Electronic Apparatus and System

    Science.gov (United States)

    Ray, William Johnstone (Inventor); Lowenthal, Mark D. (Inventor); Shotton, Neil O. (Inventor); Blanchard, Richard A. (Inventor); Lewandowski, Mark Allan (Inventor); Fuller, Kirk A. (Inventor); Frazier, Donald Odell (Inventor)

    2018-01-01

    The present invention provides an electronic apparatus, such as a lighting device comprised of light emitting diodes (LEDs) or a power generating apparatus comprising photovoltaic diodes, which may be created through a printing process, using a semiconductor or other substrate particle ink or suspension and using a lens particle ink or suspension. An exemplary apparatus comprises a base; at least one first conductor; a plurality of diodes coupled to the at least one first conductor; at least one second conductor coupled to the plurality of diodes; and a plurality of lenses suspended in a polymer deposited or attached over the diodes. The lenses and the suspending polymer have different indices of refraction. In some embodiments, the lenses and diodes are substantially spherical, and have a ratio of mean diameters or lengths between about 10:1 and 2:1. The diodes may be LEDs or photovoltaic diodes, and in some embodiments, have a junction formed at least partially as a hemispherical shell or cap.

  2. 3D inversion and modeling of magnetic and gravimetric data characterizing the geophysical anomaly source in Pratinha I in the southeast of Brazil

    Science.gov (United States)

    Louro, Vinicius Hector Abud; Mantovani, Marta Silvia Maria

    2012-05-01

    The Alto do Paranaíba Igneous Province (APIP) is known for its great mineral exploratory interest in phosphates, niobium, titanium, and diamonds, among others. In the years of 2005 and 2006, the Economic Development Company of Minas Gerais (CODEMIG — http://www.comig.com.br/) performed an airborne magnetic survey over the portion of this igneous province which belongs to Minas Gerais state, denominated Area 7. This survey revealed at the coordinates (19°45'S, 46°10'W) a tripolar anomaly here referred as Pratinha I. This anomaly does not present evidences of outcropping or topographic remodeling. So, boreholes or studies over its sources make the geophysical methods the best and less expensive solution for studying the body in its subsurface. Besides, two gravimetric ground surveys were performed in 2009 and 2010, confirming the existence of a density contrast over the region of the magnetic anomaly. Therefore, through the magnetometry and gravimetry processing, 3D modeling and inversions, it was possible to estimate the geometry, density and magnetic susceptibility, which when analyzed with the regional geology, enabled the proposition of an igneous intrusion of probable alkaline or kamafugitic composition to justify the gravimetric and magnetic response in the region.

  3. Dynamic Three-Dimensional Geometry of the Aortic Valve Apparatus-A Feasibility Study

    NARCIS (Netherlands)

    Khamooshian, Arash; Amador, Yannis; Hai, Ting; Jeganathan, Jelliffe; Saraf, Maria; Mahmood, Eitezaz; Matyal, Robina; Khabbaz, Kamal R.; Mariani, Massimo; Mahmood, Feroze

    OBJECTIVE: To provide (1) an overview of the aortic valve (AV) apparatus anatomy and nomenclature, and (2) data regarding the normal AV apparatus geometry and dynamism during the cardiac cycle obtained from three-dimensional transesophageal echocardiography (3D TEE). DESIGN: Retrospective

  4. Method and apparatus for measuring electromagnetic radiation

    Science.gov (United States)

    Been, J. F. (Inventor)

    1973-01-01

    An apparatus and method are described in which the capacitance of a semiconductor junction subjected to an electromagnetic radiation field is utilized to indicate the intensity or strength of the radiation.

  5. Charge exchange cooling in the tandem mirror plasma confinement apparatus

    Science.gov (United States)

    Logan, B. Grant

    1978-01-01

    Method and apparatus for cooling a plasma of warm charged species confined in the center mirror cell of the tandem mirror apparatus by injecting cold neutral species of the plasma into at least one mirroring region of the center mirror cell, the cooling due to the loss of warm charged species through charge exchange with the cold neutral species with resulting diffusion of the warm neutral species out of the plasma.

  6. Method and apparatus for controlling gas evolution from chemical reactions

    Science.gov (United States)

    Skorpik, James R.; Dodson, Michael G.

    1999-01-01

    The present invention is directed toward monitoring a thermally driven gas evolving chemical reaction with an acoustic apparatus. Signals from the acoustic apparatus are used to control a heater to prevent a run-away condition. A digestion module in combination with a robotic arm further automate physical handling of sample material reaction vessels. The invention is especially useful for carrying out sample procedures defined in EPA Methods SW-846.

  7. Charge exchange cooling in the tandem mirror plasma confinement apparatus

    International Nuclear Information System (INIS)

    Logan, B.G.

    1978-01-01

    A method and apparatus are described for cooling a plasma confined in the center mirror cell of the tandem mirror apparatus by injecting cold neutral species of the plasma into at least one mirroring region of the center mirror cell. The cooling is due to the loss of warm charged species through charge exchange with the cold neutral species with resulting diffusion of the warm neutral species out of the plasma

  8. Analysis apparatus and method of analysis

    International Nuclear Information System (INIS)

    1976-01-01

    A continuous streaming method developed for the excution of immunoassays is described in this patent. In addition, a suitable apparatus for the method was developed whereby magnetic particles are automatically employed for the consecutive analysis of a series of liquid samples via the RIA technique

  9. Isotope diagnostics apparatus

    International Nuclear Information System (INIS)

    Herrschaft, H.

    1976-01-01

    The invention relates to a measuring probe for an isotope diagnostics apparatus to determine the distribution of radioactive substances in a body by measuring the radiation emanating from this body by means of a multiplicity of measuring probes directed simultaneously towards areas of measuring surfae and carried in guidances of a holding block. The measuring results of the individual probes are recorded separately, thus allowing the possibility of being evaluated separately, too. Measuring probes of this kind are used in multi-channel measuring objects and are useful particularly for determining the regional cerebral blood flow. (orig./ORU) [de

  10. Tomographic scanning apparatus

    International Nuclear Information System (INIS)

    Abele, M.

    1983-01-01

    A computerized tomographic scanning apparatus suitable for diagnosis and for improving target identification in stereotactic neurosurgery is described. It consists of a base, a source of penetrating energy, a detector which produces scanning signals and detector positioning means. A frame with top and bottom arms secures the detector and source to the top and bottom arms respectively. A drive mechanism rotates the frame about an axis along which the frame may also be moved. Finally, the detector may be moved relative to the bottom arm in a direction contrary to the rotation of the frame. (U.K.)

  11. Double bypasses soxhlet apparatus for extraction of piperine from Piper nigrum

    Directory of Open Access Journals (Sweden)

    R. Subramanian

    2016-09-01

    Full Text Available A simple modified soxhlet extractor, double bypasses sidearm soxhlet apparatus (DBSA was designed and employed for extraction of piperine from Piper nigrum. Total extraction time, time taken for a cycle and yield observed in the double bypass sidearm soxhlet apparatus was compared with the soxhlet apparatus. Extraction time, time taken for an extraction cycle and yield of crude piperine obtained in DBSA were 12 ± 1 h, 8 ± 1.00 min, and 3.90 ± 0.10 g whereas the results obtained in the soxhlet method were 22 ± 1 h, 16 ± 1.00 min, and 3.80 ± 0.18 g, respectively. The results obtained in DBSA have demonstrated that this approach is as efficient as the soxhlet apparatus with drastic reduction of extraction time. On the basis of this result, we propose DBSA as the most efficient method and an alternative to the soxhlet extractor.

  12. Apparatus for inspecting a irradiated nuclear fuel rod

    International Nuclear Information System (INIS)

    Saura, Hideaki; Yonemura, Eizo.

    1975-01-01

    Object: To increase safety and inspection efficiency by operating irradiated fuel rods, which are accommodated in a water-filled pool after being taken out from the reactor. Structure: When making inspection of irradiated fuel rods, particularly the cladding tube thereof, a fuel box which stores irradiated fuel rods in a water pool is secured to a securement mechanism with slime removal apparatus and inspection apparatus on either side capable of being vertically moved, and it is then stopped at a water depth of about 2 meters. When the lid of the box is opened, irradiated fuel rods are taken out with gripping means and then secured together with the gripping means to an operation base provided on the outside of the pool. Thereafter, the box is lowered by operating pedals on the operation base to completely pull out the irradiated fuel rods from the box, and the irradiated fuel rods are then horizontally moved and then held in a suspended state. Next a slime removal apparatus in raised by operating pedals and an inspection element assembly are progressively raised for inspection of the state of the cladding tube of each fuel rod after removal of slime therefrom. (Nakamura, S.)

  13. Low-energy ion-beam deposition apparatus equipped with surface analysis system

    International Nuclear Information System (INIS)

    Ohno, Hideki; Aoki, Yasushi; Nagai, Siro.

    1994-10-01

    A sophisticated apparatus for low energy ion beam deposition (IBD) was installed at Takasaki Radiation Chemistry Research Establishment of JAERI in March 1991. The apparatus is composed of an IBD system and a real time/in-situ surface analysis system for diagnosing deposited thin films. The IBD system provides various kinds of low energy ion down to 10 eV with current density of 10 μA/cm 2 and irradiation area of 15x15 mm 2 . The surface analysis system consists of RHEED, AES, ISS and SIMS. This report describes the characteristics and the operation procedure of the apparatus together with some experimental results on depositing thin carbon films. (author)

  14. Improvements relating to apparatus for examining bodies by means of penetrating radiation

    International Nuclear Information System (INIS)

    Hounsfield, G.N.

    1977-01-01

    Improved radiographic apparatus is described for examining the human body. It is applicable to either X- or γ-radiation. Some disadvantages of the apparatus described in BP 1283915 are pointed out and the present apparatus seeks to reduce these disadvantages. One such disadvantage is that the time taken by scanning is relatively long since the transverse scanning has to be sufficiently slow to allow an adequate photon count to be obtained on each of closely space parallel beam paths; this affects the results obtained from parts of the patient's body liable to be obscured by movement of the patient's organs. The apparatus described includes means for orbiting the source and detector around the body so as to irradiate a planar section of the body from a number of different directions, with means for moving the source and detector laterally so as to scan the radiation across the planar section. (U.K.)

  15. Pyrolysis process and apparatus

    Science.gov (United States)

    Lee, Chang-Kuei

    1983-01-01

    This invention discloses a process and apparatus for pyrolyzing particulate coal by heating with a particulate solid heating media in a transport reactor. The invention tends to dampen fluctuations in the flow of heating media upstream of the pyrolysis zone, and by so doing forms a substantially continuous and substantially uniform annular column of heating media flowing downwardly along the inside diameter of the reactor. The invention is particularly useful for bituminous or agglomerative type coals.

  16. Pulse radiolysis apparatus for monitoring at 2000 Å

    DEFF Research Database (Denmark)

    Christensen, H.C.; Nilsson, G.; Pagsberg, Palle Bjørn

    1969-01-01

    A pulse radiolysis apparatus with photometric monitoring has been built around an 11 MeV, 250 mA peak current, linac that delivers single 0.25 to 4 μsec pulses. The novel features of the apparatus include (1) a 450 W xenon lamp as the analyzing light source which in pulsed operation had a 25 times...... increased luminance; (2) a fast electronic switch that cut out the signal due to the Cerenkov radiation; (3) a secondary emission chamber that allowed the simultaneous measurement of the current and the direction of the pulsed electron beam; and (4) a system for remote controlled change of liquid samples...

  17. Power control apparatus and methods for electric vehicles

    Science.gov (United States)

    Gadh, Rajit; Chung, Ching-Yen; Chu, Chi-Cheng; Qiu, Li

    2016-03-22

    Electric vehicle (EV) charging apparatus and methods are described which allow the sharing of charge current between multiple vehicles connected to a single source of charging energy. In addition, this charge sharing can be performed in a grid-friendly manner by lowering current supplied to EVs when necessary in order to satisfy the needs of the grid, or building operator. The apparatus and methods can be integrated into charging stations or can be implemented with a middle-man approach in which a multiple EV charging box, which includes an EV emulator and multiple pilot signal generation circuits, is coupled to a single EV charge station.

  18. The new PVLAS apparatus for detection of magnetic birefringence of vacuum

    International Nuclear Information System (INIS)

    Della Valle, F.; Di Domenico, G.; Gastaldi, U.; Milotti, E.; Messineo, G.; Pengo, R.; Piemontese, L.; Ruoso, G.; Zavattini, G.

    2013-01-01

    The PVLAS experiment aims at the observation and measurement of the effect of magnetic birefringence of vacuum (MBV) predicted by Quantum Electrodynamics. We describe here the new PVLAS apparatus which is currently being set up in INFN Ferrara. The apparatus features two rotating permanent dipole magnets and an ellipsometer operating under UHV with a high finesse Fabry–Perot cavity

  19. A new apparatus for electron-ion multiple coincidence momentum imaging spectroscopy

    International Nuclear Information System (INIS)

    Morishita, Y.; Kato, M.; Pruemper, G.; Liu, X.-J.; Lischke, T.; Ueda, K.; Tamenori, Y.; Oura, M.; Yamaoka, H.; Suzuki, I.H.; Saito, N.

    2006-01-01

    We have developed a new experimental apparatus for the electron-ion multiple coincidence momentum imaging spectroscopy in order to obtain the angular distributions of vibration-resolved photoelectrons from molecules fixed in space. The apparatus consists of a four-stage molecular supersonic jet and a spectrometer analyzing three-dimensional momenta of fragment ions and electrons in coincidence

  20. The ALPHA antihydrogen trapping apparatus

    Energy Technology Data Exchange (ETDEWEB)

    Amole, C. [Department of Physics and Astronomy, York University, Toronto ON Canada, M3J 1P3 (Canada); Andresen, G.B. [Department of Physics and Astronomy, Aarhus University, DK-8000 Aarhus C (Denmark); Ashkezari, M.D. [Department of Physics, Simon Fraser University, Burnaby, BC Canada, V5A 1S6 (Canada); Baquero-Ruiz, M. [Department of Physics, University of California at Berkeley, Berkeley, CA 94720-7300 (United States); Bertsche, W. [Department of Physics, College of Science, Swansea University, Swansea SA2 8PP (United Kingdom); School of Physics and Astronomy, University of Manchester, Manchester M13 9PL (United Kingdom); The Cockcroft Institute, Warrington WA4 4AD (United Kingdom); Bowe, P.D. [Department of Physics and Astronomy, Aarhus University, DK-8000 Aarhus C (Denmark); Butler, E. [Physics Department, CERN, CH-1211 Geneva 23 (Switzerland); Capra, A. [Department of Physics and Astronomy, York University, Toronto ON Canada, M3J 1P3 (Canada); Carpenter, P.T. [Department of Physics, Auburn University, Auburn, AL 36849-5311 (United States); Cesar, C.L. [Instituto de Física, Universidade Federal do Rio de Janeiro, Rio de Janeiro 21941-972 (Brazil); Chapman, S. [Department of Physics, University of California at Berkeley, Berkeley, CA 94720-7300 (United States); Charlton, M.; Deller, A.; Eriksson, S. [Department of Physics, College of Science, Swansea University, Swansea SA2 8PP (United Kingdom); Escallier, J. [Brookhaven National Laboratory, Upton, NY 11973 (United States); Fajans, J. [Department of Physics, University of California at Berkeley, Berkeley, CA 94720-7300 (United States); Friesen, T. [Department of Physics and Astronomy, University of Calgary, Calgary AB, Canada, T2N 1N4 (Canada); Fujiwara, M.C.; Gill, D.R. [TRIUMF, 4004 Wesbrook Mall, Vancouver BC, Canada V6T 2A3 (Canada); Gutierrez, A. [Department of Physics and Astronomy, University of British Columbia, Vancouver BC, Canada V6T 1Z4 (Canada); and others

    2014-01-21

    The ALPHA collaboration, based at CERN, has recently succeeded in confining cold antihydrogen atoms in a magnetic minimum neutral atom trap and has performed the first study of a resonant transition of the anti-atoms. The ALPHA apparatus will be described herein, with emphasis on the structural aspects, diagnostic methods and techniques that have enabled antihydrogen trapping and experimentation to be achieved.

  1. Apparatus for distillation of bituminous material

    Energy Technology Data Exchange (ETDEWEB)

    Carthaus, E; von Rittersberg, K; Abraham, A

    1917-05-03

    Apparatus for dry distillation of bituminous material, such as oil shale and brown coal with simultaneous fractional separation of the distillate, consists in the fact, that the domed water-cooled condenser, arranged above the conveyer carrying it, is divided by double vertical partitions in the chamber.

  2. Apparatus for monitoring two-phase flow

    International Nuclear Information System (INIS)

    Sheppard, J.D.; Tong, L.S.

    1977-01-01

    A method and apparatus for monitoring two-phase flow is provided that is particularly related to the monitoring of transient two-phase (liquid-vapor) flow rates such as may occur during a pressurized water reactor core blow-down. The present invention essentially comprises the use of flanged wire screens or similar devices, such as perforated plates, to produce certain desirable effects in the flow regime for monitoring purposes. One desirable effect is a measurable and reproducible pressure drop across the screen. The pressure drop can be characterized for various known flow rates and then used to monitor nonhomogeneous flow regimes. Another useful effect of the use of screens or plates in nonhomogeneous flow is that such apparatus tends to create a uniformly dispersed flow regime in the immediate downstream vicinity. This is a desirable effect because it usually increases the accuracy of flow rate measurements determined by conventional methods. 3 claims, 9 figures

  3. An apparatus to search for free neutron-antineutron oscillations

    International Nuclear Information System (INIS)

    Bressi, G.; Calligarich, E.; Cambiaghi, M.; Dolfini, R.; Gigli Berzolari, A.; Lanza, A.; Liguori, G.; Mauri, F.; Piazzoli, A.; Ratti, S.P.; Scannicchio, D.; Torre, P.; Conversi, M.; De Zorzi, G.; Massa, F.; Zanello, D.; Cardarelli, R.; Santonico, R.; Terrani, M.

    1987-01-01

    After recalling the phenomenology of neutron-antineutron oscillations expected to occur if the baryon number is not rigorously conserved, the apparatus developed and used in a search for such a process, currently being carried out at the Pavia nuclear reactor, is described in some detail. The apparatus involves a large volume neutron channel (≅ 20 m 3 ) in which the earth magnetic field has been reduced by a factor 50, and large area detectors (scintillators, flash chambers and 'resistive plate counters') operating under conditions of extremely severe background from the reactor. (orig.)

  4. Apparatus for posting materials into and out of enclosures

    International Nuclear Information System (INIS)

    Sperinck, W.A.; Ashcroft, K.C.

    1986-01-01

    The patent concerns an apparatus for posting toxic or radioactive materials into and out of a high integrity enclosure, such as a glovebox, through a port in a wall of the enclosure. The apparatus comprises a container for the materials, with a lid which is engageable with a door for the port, and the container is supported in a cradle. The door cannot be opened in the absence of a container in the cradle, and the container cannot be removed when the door and lid unit is away from the port. (UK)

  5. Apparatus for producing carbon-coated nanoparticles and carbon nanospheres

    Energy Technology Data Exchange (ETDEWEB)

    Perry, W. Lee; Weigle, John C.; Phillips, Jonathan

    2015-10-20

    An apparatus for producing carbon-coated nano- or micron-scale particles comprising a container for entraining particles in an aerosol gas, providing an inlet for carbon-containing gas, providing an inlet for plasma gas, a proximate torch for mixing the aerosol gas, the carbon-containing gas, and the plasma gas, bombarding the mixed gases with microwaves, and providing a collection device for gathering the resulting carbon-coated nano- or micron-scale particles. Also disclosed is a method and apparatus for making hollow carbon nano- or micro-scale spheres.

  6. Apparatus and method for magnetically unloading a rotor bearing

    Energy Technology Data Exchange (ETDEWEB)

    Sanders, Seth Robert

    2018-02-13

    An apparatus and method for unloading a rotor bearing is described. The apparatus includes an electromagnet for levitating the rotor. In one embodiment, a sensor of the magnetic field near the electromagnet is used to control the current to levitate the rotor. In another embodiment, a method is provided that includes rotating the rotor, increasing the current to levitate the rotor and decrease the gap between electromagnet and rotor, and then reducing the current to levitate the rotor with a minimal amount of electric power to the electromagnet.

  7. Method and apparatus for vibrating a substrate during material formation

    Science.gov (United States)

    Bailey, Jeffrey A [Richland, WA; Roger, Johnson N [Richland, WA; John, Munley T [Benton City, WA; Walter, Park R [Benton City, WA

    2008-10-21

    A method and apparatus for affecting the properties of a material include vibrating the material during its formation (i.e., "surface sifting"). The method includes the steps of providing a material formation device and applying a plurality of vibrations to the material during formation, which vibrations are oscillations having dissimilar, non-harmonic frequencies and at least two different directions. The apparatus includes a plurality of vibration sources that impart vibrations to the material.

  8. Safety apparatus for serious radioactive accidents (1962)

    International Nuclear Information System (INIS)

    Estournel, R.; Rodier, J.

    1962-01-01

    In the case of a serious radioactive accident, radioactive dust and gases may be released into the atmosphere. It is therefore necessary to be able to evaluate rapidly the importance of the risk to the surrounding population, and to be able to ensure, even in the event of an evacuation of the Centre, the continuation of the radioactivity analyses and the decontamination of the personnel. For this, the Anti-radiation Protection Service at Marcoule has organised mobile detection teams and designed a mobile laboratory and a mobile shower-unit. After describing the duty of the mobile teams, the report gives a description of the apparatus which would be used at the Marcoule Centre in the case of a serious radioactive accident. The method of using this apparatus is given. (authors) [fr

  9. Apparatus and method for assembling fuel elements

    International Nuclear Information System (INIS)

    Arya, S.P.

    1978-01-01

    A nuclear fuel element assembling method and apparatus is preferably operable under programmed control unit to receive fuel rods from storage, arrange them into axially aligned stacks of closely monitored length, and transfer the stacks of fuel rods to a loading device for insertion into longitudinal passages in the fuel elements. In order to handle large numbers of one or more classifications of fuel rods or other cylindrical parts, the assembling apparatus includes at least two feed troughs each formed by a pair of screw members with a movable table having a plurality of stacking troughs for alignment with the feed troughs and with a conveyor for delivering the stacks to the loading device, the fuel rods being moved along the stacking troughs upon a fluid cushion. 23 claims, 6 figures

  10. Apparatus, system, and method for traffic monitoring

    KAUST Repository

    Claudel, Christian G.

    2016-08-25

    An apparatus, system, and method for traffic monitory can have a Lagrangian inertial measurement unit. The Lagrangian inertial measurement unit can have a processor, an accelerometer, a gyroscope, and/or a wireless transmitter. The processor can have an integrated direction cosine matrix. The accelerometer can be configured to measure linear accelerations of a vehicle and/or can communicate measured linear acceleration to the processor. The gyroscope can be configured to measure rotational accelerations of the vehicle and/or can communicate measured rotational acceleration to the processor. The processor can be configured to calculate estimated vehicle speed and/or estimated vehicle attitude. The wireless transmitter can be configured to wirelessly transmit estimated vehicle speed and/or estimated vehicle attitude. The apparatus, system, and method can be integrated with a wireless sensor network.

  11. A low cost apparatus for measuring the xylem hydraulic conductance in plants

    Directory of Open Access Journals (Sweden)

    Luciano Pereira

    2012-01-01

    Full Text Available Plant yield and resistance to drought are directly related to the efficiency of the xylem hydraulic conductance and the ability of this system to avoid interrupting the flow of water. In this paper we described in detail the assembling of an apparatus proposed by TYREE et al. (2002, and its calibration, as well as low cost adaptations that make the equipment accessible for everyone working in this research area. The apparatus allows measuring the conductance in parts of roots or shoots (root ramifications or branches, or in the whole system, in the case of small plants or seedlings. The apparatus can also be used to measure the reduction of conductance by embolism of the xylem vessels. Data on the hydraulic conductance of eucalyptus seedlings obtained here and other reports in the literature confirm the applicability of the apparatus in physiological studies on the relationship between productivity and water stress.

  12. Diseases of the branquial apparatus

    International Nuclear Information System (INIS)

    Perez-Candela, V.; Wiehoff, A.; Avial, R.

    2000-01-01

    To correlate ht embryologic and radiologic findings in the branchial apparatus or system with the anomalies that can occur. We reviewed the cases of branchial anomalies examined over the past 6 years, finding periparotid cysts at the first branchial cleft (n=2), cysts (n=13) and fistulas (n=4) at the second, and cysts (n=2) and thymopharyngeal cysts (n=3) at the third. The studies included ultrasound, computed tomography, magnetic resonance imaging and fistulography. All the patients underwent surgery, with histological confirmation. Knowledge of the embryology of the branchial apparatus or system helps in the understanding of anomalies, which appear as cervical cystic masses, mainly located along the anterior border of the sternocleidomastoid (SCM) muscle, or as fistulas running from the exterior to the pharyngeal lumen at the level of the tonsillar fossa, sometimes forming sinuses, that is fistulas that are blind at either the external or internal end. The most common anomalies arise from the second branchial cleft and are easily diagnosed in the presence of a cystic mass located to one side of the SCM muscle, behind the submandibular gland and occupying the carotid space. (Author) 14 refs

  13. Nuclear fuel rod loading apparatus

    International Nuclear Information System (INIS)

    King, H.B.; Macivergan, R.; Mckenzie, G.W.

    1980-01-01

    An apparatus incorporating a microprocessor control is provided for automatically loading nuclear fuel pellets into fuel rods commonly used in nuclear reactor cores. The apparatus comprises a split ''v'' trough for assembling segments of fuel pellets in rows and a shuttle to receive the fuel pellets from the split ''v'' trough when the two sides of the split ''v'' trough are opened. The pellets are weighed while in the shuttle, and the shuttle then moves the pellets into alignment with a fuel rod. A guide bushing is provided to assist the transfer of the pellets into the fuel rod. A rod carousel which holds a plurality of fuel rods presents the proper rod to the guide bushing at the appropriate stage in the loading sequence. The bushing advances to engage the fuel rod, and the shuttle advances to engage the guide bushing. The pellets are then loaded into the fuel rod by a motor operated push rod. The guide bushing includes a photocell utilized in conjunction with the push rod to measure the length of the row of fuel pellets inserted in the fuel rod

  14. Conveyor with rotary airlock apparatus

    Science.gov (United States)

    Kronbert, J.W.

    1993-01-01

    This invention is comprised of an apparatus for transferring objects from a first region to a second region, the first and second regions having differing atmospheric environments. The apparatus includes a shell having an entrance and an exit, a conveyer belt running through the shell from the entrance to the exit, and a horizontally mounted `revolving door` with at least four vanes revolving about its axis. The inner surface of the shell and the top surface of the conveyer belt act as opposing walls of the `revolving door`. The conveyer belt dips as it passes under but against the revolving vanes so as not to interfere with them but to engage at least two of the vanes and define thereby a moving chamber. Preferably, the conveyer belt has ridges or grooves on its surface that engage the edges of the vanes and act to rotate the vane assembly. Conduits are provided that communicate with the interior of the shell and allow the adjustment of the atmosphere of the moving chamber or recovery of constituents of the atmosphere of the first region from the moving chamber before they escape to the second region.

  15. Nuclear reactor core servicing apparatus

    International Nuclear Information System (INIS)

    Andrea, C.

    1977-01-01

    Disclosed is an improved core servicing apparatus for a nuclear reactor of the type having a reactor vessel, a vessel head having a head penetration therethrough, a removable plug adapted to fit in the head penetration, and a core of the type having an array of elongated assemblies. The improved core servicing apparatus comprises a plurality of support columns suspended from the removable plug and extending downward toward the nuclear core, rigid support means carried by each of the support columns, and a plurality of servicing means for each of the support columns for servicing a plurality of assemblies. Each of the plurality of servicing means for each of the support columns is fixedly supported in a fixed array from the rigid support means. Means are provided for rotating the rigid support means and servicing means between condensed and expanded positions. When in the condensed position, the rigid support means and servicing means lie completely within the coextensive boundaries of the plug, and when in the expanded position, some of the rigid support means and servicing means lie without the coextensive boundaries of the plug

  16. Pipe and hose decontamination apparatus

    International Nuclear Information System (INIS)

    Fowler, D.E.

    1985-01-01

    A pipe and hose decontamination apparatus is disclosed using freshly filtered high pressure Freon solvent in an integrated closed loop to remove radioactive particles or other contaminants from items having a long cylindrical geometry such as hoses, pipes, cables and the like. The pipe and hose decontamination apparatus comprises a chamber capable of accomodating a long cylindrical work piece to be decontaminated. The chamber has a downward sloped bottom draining to a solvent holding tank. An entrance zone, a cleaning zone and an exit drying zone are defined within the chamber by removable partitions having slotted rubber gaskets in their centers. The entrance and exit drying zones contain a horizontally mounted cylindrical housing which supports in combination a plurality of slotted rubber gaskets and circular brushes to initiate mechanical decontamination. Solvent is delivered at high pressure to a spray ring located in the cleaning zone having a plurality of nozzles surrounding the work piece. The solvent drains into a solvent holding tank located below the nozzles and means are provided for circulating the solvent to and from a solvent cleaning, distilling and filter unit

  17. Filter apparatus for actively reducing noise

    NARCIS (Netherlands)

    Berkhoff, Arthur P.; Nijsse, G.

    2010-01-01

    A filter apparatus for reducing noise from a primary noise source, comprising a secondary source signal connector for generating secondary noise to reduce said primary noise and a sensor connector for connecting to a sensor for measuring said primary and secondary noise as an error signal. A first

  18. Apparatus and method for reconstructing data

    International Nuclear Information System (INIS)

    1981-01-01

    A method and apparatus is described for constructing a two-dimensional picture of an object slice from linear projections of radiation not absorbed or scattered by the object, using convolution methods of data reconstruction, useful in the fields of medical radiology, microscopy, and non-destructive testing. (U.K.)

  19. Method and apparatus for calibrating spectrophotometers

    NARCIS (Netherlands)

    Schreutelkamp, F.H.

    2003-01-01

    The present invention relates to a method of calibrating spectrophotometers by placing one or more filters in the light path of the spectrophotometer and measuring the amount of radiation by means of a detector. The present invention furthermore relates to an apparatus to be used with such a method.

  20. Apparatus, system, and method for traffic monitoring

    KAUST Repository

    Claudel, Christian G.; Mousa, Mustafa; Abdulaal, Mohammed

    2016-01-01

    An apparatus, system, and method for traffic monitory can have a Lagrangian inertial measurement unit. The Lagrangian inertial measurement unit can have a processor, an accelerometer, a gyroscope, and/or a wireless transmitter. The processor can