WorldWideScience

Sample records for grand raiden spectrometer

  1. Magnetic spectrometer Grand Raiden

    Fujiwara, M.; Akimune, H.; Daito, I.; Fujimura, H.; Fujita, Y.; Hatanaka, K.; Ikegami, H.; Katayama, I.; Nagayama, K.; Matsuoka, N.; Morinobu, S.; Noro, T.; Yoshimura, M.; Sakaguchi, H.; Sakemi, Y.; Tamii, A.; Yosoi, M.

    1999-01-01

    A high-resolution magnetic spectrometer called 'Grand Raiden' is operated at the RCNP ring cyclotron facility in Osaka for nuclear physics studies at intermediate energies. This magnetic spectrometer has excellent ion-optical properties. In the design of the spectrometer, the second-order dispersion matching condition has been taken into account, and almost all the aberration terms such as (x vertical bar θ 3 ), (x vertical bar θφ 2 ), (x vertical bar θ 2 δ) and (x vertical bar θδ 2 ) in a third-order matrix calculation are optimized. A large magnetic rigidity of the spectrometer (K = 1400 MeV) gives a great advantage to measure the charge-exchange ( 3 He, t) reactions at 450 MeV. The ability of the high-resolution measurement has been demonstrated. Various coincidence measurements are performed to study the nuclear structures of highly excited states through decay properties of nuclear levels following nuclear reactions at intermediate energies

  2. New data acquisition system for the focal plane polarimeter of the Grand Raiden spectrometer

    Tamii, A.; Sakaguchi, H.; Takeda, H.; Yosoi, M.; Akimune, H.; Fujiwara, M.; Ogata, H.; Tanaka, M.; Togawa, H.

    1996-01-01

    This paper describes a new data acquisition system for the focal plane polarimeter of the Grand Raiden spectrometer at the Research Center for Nuclear Physics (RCNP) in Osaka, Japan. Data are acquired by a Creative Electronic Systems (CES) Starburst, which is a CAMAC auxiliary crate controller equipped with a Digital Equipment Corporation (DEC) J11 microprocessor., The data on the Starburst are transferred to a VME single-board computer. A VME reflective memory module broadcasts the data to other systems through a fiber-optic link. A data transfer rate of 2.0 Mbytes/s between VME modules has been achieved by reflective memories. This rate includes the overhead of buffer management. The overall transfer rate, however, is limited by the performance of the Starburst to about 160 Kbytes/s at maximum. In order to further improve the system performance, the authors developed a new readout module called the Rapid Data Transfer Module (RDTM). RDTM's transfer data from LeCroy PCOS III's or 4298's, and FERA/FERET's directly to CES 8170 High Speed Memories (HSM) in VME crates. The data transfer rate of the RDTM from PCOS III's to the HSM is about 4 Mbytes/s

  3. Peter J Derrick and the Grand Scale 'Magnificent Mass Machine' mass spectrometer at Warwick.

    Colburn, A W; Derrick, Peter J; Bowen, Richard D

    2017-12-01

    The value of the Grand Scale 'Magnificent Mass Machine' mass spectrometer in investigating the reactivity of ions in the gas phase is illustrated by a brief analysis of previously unpublished work on metastable ionised n-pentyl methyl ether, which loses predominantly methanol and an ethyl radical, with very minor contributions for elimination of ethane and water. Expulsion of an ethyl radical is interpreted in terms of isomerisation to ionised 3-pentyl methyl ether, via distonic ions and, possibly, an ion-neutral complex comprising ionised ethylcyclopropane and methanol. This explanation is consistent with the closely similar behaviour of the labelled analogues, C 3 H 7 CH 2 CD 2 OCH 3 +. and C 3 H 7 CD 2 CH 2 OCH 3 +. , and is supported by the greater kinetic energy release associated with loss of ethane from ionised n-propyl methyl ether compared to that starting from directly generated ionised 3-pentyl methyl ether.

  4. Search for an annual modulation of dark-matter signals with a germanium spectrometer at the Sierra Grande Laboratory

    Abriola, D.; Brodzinski, R.L.; Collar, J.I.; Di Gregorio, D.E.; Farach, H.A.; Garcia, E.; Gattone, A.O.; Guerard, C.K.; Hasenbalg, F.; Huck, H.; Miley, H.S.; Morales, A.; Morales, J.; Ortiz de Solorzano, A.; Puimedon, J.; Reeves, J.H.; Salinas, A.; Sarsa, M.L.; Villar, J.A.

    1999-01-01

    Data collected during three years with a germanium spectrometer at the Sierra Grande underground laboratory have been analyzed for distinctive features of annual modulation of the signal induced by WIMP dark matter candidates. The main motivation for this analysis was the recent suggestion by the DAMA/NaI Collaboration that a yearly modulation signal could not be rejected at the 90% confidence level when analyzing data obtained with a high-mass low-background scintillator detector. We performed two different analyses of the data: First, the statistical distribution of modulation-significance variables (expected from an experiment running under the conditions of Sierra Grande) was compared with the same variables obtained from the data. Second, the data were analyzed in energy bins as an independent check of the first result and to allow for the possibility of a crossover in the expected signal. In both cases no statistically significant deviation from the null result was found, which could support the hypothe...

  5. spectrometer

    J. K. Hedelius

    2016-08-01

    Full Text Available Bruker™ EM27/SUN instruments are commercial mobile solar-viewing near-IR spectrometers. They show promise for expanding the global density of atmospheric column measurements of greenhouse gases and are being marketed for such applications. They have been shown to measure the same variations of atmospheric gases within a day as the high-resolution spectrometers of the Total Carbon Column Observing Network (TCCON. However, there is little known about the long-term precision and uncertainty budgets of EM27/SUN measurements. In this study, which includes a comparison of 186 measurement days spanning 11 months, we note that atmospheric variations of Xgas within a single day are well captured by these low-resolution instruments, but over several months, the measurements drift noticeably. We present comparisons between EM27/SUN instruments and the TCCON using GGG as the retrieval algorithm. In addition, we perform several tests to evaluate the robustness of the performance and determine the largest sources of errors from these spectrometers. We include comparisons of XCO2, XCH4, XCO, and XN2O. Specifically we note EM27/SUN biases for January 2015 of 0.03, 0.75, –0.12, and 2.43 % for XCO2, XCH4, XCO, and XN2O respectively, with 1σ running precisions of 0.08 and 0.06 % for XCO2 and XCH4 from measurements in Pasadena. We also identify significant error caused by nonlinear sensitivity when using an extended spectral range detector used to measure CO and N2O.

  6. Monolithic spectrometer

    Rajic, Slobodan (Knoxville, TN); Egert, Charles M. (Oak Ridge, TN); Kahl, William K. (Knoxville, TN); Snyder, Jr., William B. (Knoxville, TN); Evans, III, Boyd M. (Oak Ridge, TN); Marlar, Troy A. (Knoxville, TN); Cunningham, Joseph P. (Oak Ridge, TN)

    1998-01-01

    A monolithic spectrometer is disclosed for use in spectroscopy. The spectrometer is a single body of translucent material with positioned surfaces for the transmission, reflection and spectral analysis of light rays.

  7. Construction of calibration pads facility, Walker Field, Grand Junction, Colorado

    Ward, D.L.

    1978-08-01

    A gamma-ray spectrometer facility was completed at Walker Field Airport, Grand Junction, Colorado, in November 1976. This report describes spectrometers and their calibration, the construction of the spectrometer facility, the radioelement concentrations, procedures for using the facilites, and environmental considerations

  8. Correlation spectrometer

    Sinclair, Michael B [Albuquerque, NM; Pfeifer, Kent B [Los Lunas, NM; Flemming, Jeb H [Albuquerque, NM; Jones, Gary D [Tijeras, NM; Tigges, Chris P [Albuquerque, NM

    2010-04-13

    A correlation spectrometer can detect a large number of gaseous compounds, or chemical species, with a species-specific mask wheel. In this mode, the spectrometer is optimized for the direct measurement of individual target compounds. Additionally, the spectrometer can measure the transmission spectrum from a given sample of gas. In this mode, infrared light is passed through a gas sample and the infrared transmission signature of the gasses present is recorded and measured using Hadamard encoding techniques. The spectrometer can detect the transmission or emission spectra in any system where multiple species are present in a generally known volume.

  9. Multidimensional spectrometer

    Zanni, Martin Thomas; Damrauer, Niels H.

    2010-07-20

    A multidimensional spectrometer for the infrared, visible, and ultraviolet regions of the electromagnetic spectrum, and a method for making multidimensional spectroscopic measurements in the infrared, visible, and ultraviolet regions of the electromagnetic spectrum. The multidimensional spectrometer facilitates measurements of inter- and intra-molecular interactions.

  10. Grandes remolques

    Editorial, Equipo

    1961-07-01

    Full Text Available El empleo creciente del material pesado auxiliar en la construcción de obras de ingeniería civil ha motivado la fabricación de grandes plataformas, capaces de transportar toda clase de maquinaria auxiliar. En general, este tipo de maquinaria requiere medios de transporte, pues su circulación por carreteras es lenta, obstructiva y cara, siempre que se trate de grandes distancias, caso presente en la mayoría de ocasiones en que se exige un traslado de esta maquinaria de una a otra obra.

  11. Grandes cocinas

    García de Castro, Emilio

    1957-11-01

    Full Text Available Se describen en este artículo una serie de aparatos para grandes cocinas, vistos por los autores durante un rápido viaje por Alemania. Aprovechando los datos obtenidos se analizan brevemente las necesidades de una gran cocina moderna, comentando los planos de las instalaciones en varios hoteles o instituciones de todo el mundo. La mayoría de la información.

  12. HISS spectrometer

    Greiner, D.E.

    1984-11-01

    This talk describes the Heavy Ion Spectrometer System (HISS) facility at the Lawrence Berkeley Laboratory's Bevalac. Three completed experiments and their results are illustrated. The second half of the talk is a detailed discussion of the response of drift chambers to heavy ions. The limitations of trajectory measurement over a large range in incident particle charge are presented

  13. Spectrometer gun

    Waechter, David A.; Wolf, Michael A.; Umbarger, C. John

    1985-01-01

    A hand-holdable, battery-operated, microprocessor-based spectrometer gun includes a low-power matrix display and sufficient memory to permit both real-time observation and extended analysis of detected radiation pulses. Universality of the incorporated signal processing circuitry permits operation with various detectors having differing pulse detection and sensitivity parameters.

  14. The Spectrometer

    Greenslade, Thomas B., Jr.

    2012-01-01

    In the fall of 1999 I was shown an Ocean Optics spectrometer-in-the-computer at St. Patricks College at Maynooth, Ireland, and thought that I had seen heaven. Of course, it could not resolve the sodium D-lines (I had done that many years before with a homemade wire diffraction grating), and I began to realize that inside was some familiar old…

  15. Cassini's Grand Finale Overview

    Spilker, L. J.

    2017-12-01

    After 13 years in orbit, the Cassini-Huygens Mission to Saturn ended in a science-rich blaze of glory. Cassini sent back its final bits of unique science data on September 15, 2017, as it plunged into Saturn's atmosphere, vaporizing and satisfying planetary protection requirements. Cassini's final phase covered roughly ten months and ended with the first time exploration of the region between the rings and planet. In late 2016 Cassini transitioned to a series of 20 Ring Grazing orbits with peripases just outside Saturn's F ring, providing close flybys of tiny ring moons, including Pan, Daphnis and Atlas, and high-resolution views of Saturn's A and F rings. A final Titan flyby in late April 2017 propelled Cassini across Saturn's main rings and into its Grand Finale orbits. Comprised of 22 orbits, Cassini repeatedly dove between Saturn's innermost rings and upper atmosphere to answer fundamental questions unattainable earlier in the mission. The last orbit turned the spacecraft into the first Saturn atmosphere probe. The Grand Finale orbits provided highest resolution observations of both the rings and Saturn, and in-situ sampling of the ring particle composition, Saturn's atmosphere, plasma, and innermost radiation belts. The gravitational field was measured to unprecedented accuracy, providing information on the interior structure of the planet, winds in the deeper atmosphere, and mass of the rings. The magnetic field provided insight into the physical nature of the magnetic dynamo and structure of the internal magnetic field. The ion and neutral mass spectrometer sampled the upper atmosphere for molecules that escape the atmosphere in addition to molecules originating from the rings. The cosmic dust analyzer directly sampled the composition from different parts of the main rings for the first time. Fields and particles instruments directly measured the plasma environment between the rings and planet. Science highlights and new mysteries collected in the Grand

  16. Small angle spectrometers: Summary

    Courant, E.; Foley, K.J.; Schlein, P.E.

    1986-01-01

    Aspects of experiments at small angles at the Superconducting Super Collider are considered. Topics summarized include a small angle spectrometer, a high contingency spectrometer, dipole and toroid spectrometers, and magnet choices

  17. Smartphone Spectrometers

    Willmott, Jon R.; Mims, Forrest M.; Parisi, Alfio V.

    2018-01-01

    Smartphones are playing an increasing role in the sciences, owing to the ubiquitous proliferation of these devices, their relatively low cost, increasing processing power and their suitability for integrated data acquisition and processing in a ‘lab in a phone’ capacity. There is furthermore the potential to deploy these units as nodes within Internet of Things architectures, enabling massive networked data capture. Hitherto, considerable attention has been focused on imaging applications of these devices. However, within just the last few years, another possibility has emerged: to use smartphones as a means of capturing spectra, mostly by coupling various classes of fore-optics to these units with data capture achieved using the smartphone camera. These highly novel approaches have the potential to become widely adopted across a broad range of scientific e.g., biomedical, chemical and agricultural application areas. In this review, we detail the exciting recent development of smartphone spectrometer hardware, in addition to covering applications to which these units have been deployed, hitherto. The paper also points forward to the potentially highly influential impacts that such units could have on the sciences in the coming decades. PMID:29342899

  18. Smartphone Spectrometers

    Andrew J.S. McGonigle

    2018-01-01

    Full Text Available Smartphones are playing an increasing role in the sciences, owing to the ubiquitous proliferation of these devices, their relatively low cost, increasing processing power and their suitability for integrated data acquisition and processing in a ‘lab in a phone’ capacity. There is furthermore the potential to deploy these units as nodes within Internet of Things architectures, enabling massive networked data capture. Hitherto, considerable attention has been focused on imaging applications of these devices. However, within just the last few years, another possibility has emerged: to use smartphones as a means of capturing spectra, mostly by coupling various classes of fore-optics to these units with data capture achieved using the smartphone camera. These highly novel approaches have the potential to become widely adopted across a broad range of scientific e.g., biomedical, chemical and agricultural application areas. In this review, we detail the exciting recent development of smartphone spectrometer hardware, in addition to covering applications to which these units have been deployed, hitherto. The paper also points forward to the potentially highly influential impacts that such units could have on the sciences in the coming decades.

  19. Cassini's Grand Finale Science Highlights

    Spilker, Linda

    2017-10-01

    After 13 years in orbit, the Cassini-Huygens Mission to Saturn ended in a science-rich blaze of glory. Cassini returned its final bits of unique science data on September 15, 2017, as it plunged into Saturn's atmosphere satisfying planetary protection requirements. Cassini's Grand Finale covered a period of roughly five months and ended with the first time exploration of the region between the rings and planet.The final close flyby of Titan in late April 2017 propelled Cassini across Saturn’s main rings and into its Grand Finale orbits; 22 orbits that repeatedly dove between Saturn’s innermost rings and upper atmosphere making Cassini the first spacecraft to explore this region. The last orbit turned the spacecraft into the first Saturn upper atmospheric probe.The Grand Finale orbits provided highest resolution observations of both the rings and Saturn, and in-situ sampling of the ring particle composition, Saturn's atmosphere, plasma, and innermost radiation belts. The gravitational field was measured to unprecedented accuracy, providing information on the interior structure of the planet, winds in the deeper atmosphere, and mass of the rings. The magnetic field provided insight into the physical nature of the magnetic dynamo and structure of the internal magnetic field. The ion and neutral mass spectrometer sampled the upper atmosphere for molecules that escape the atmosphere in addition to molecules originating from the rings. The cosmic dust analyzer directly sampled the composition from different parts of the main rings for the first time. Fields and particles instruments directly measured the plasma environment between the rings and planet.Science highlights and new mysteries gleaned to date from the Grand Finale orbits will be discussed.The research described in this paper was carried out in part at the Jet Propulsion Laboratory, California Institute of Technology, under a contract with the National Aeronautics and Space Administration. Copyright 2017

  20. Spherical grating spectrometers

    O'Donoghue, Darragh; Clemens, J. Christopher

    2014-07-01

    We describe designs for spectrometers employing convex dispersers. The Offner spectrometer was the first such instrument; it has almost exclusively been employed on satellite platforms, and has had little impact on ground-based instruments. We have learned how to fabricate curved Volume Phase Holographic (VPH) gratings and, in contrast to the planar gratings of traditional spectrometers, describe how such devices can be used in optical/infrared spectrometers designed specifically for curved diffraction gratings. Volume Phase Holographic gratings are highly efficient compared to conventional surface relief gratings; they have become the disperser of choice in optical / NIR spectrometers. The advantage of spectrometers with curved VPH dispersers is the very small number of optical elements used (the simplest comprising a grating and a spherical mirror), as well as illumination of mirrors off axis, resulting in greater efficiency and reduction in size. We describe a "Half Offner" spectrometer, an even simpler version of the Offner spectrometer. We present an entirely novel design, the Spherical Transmission Grating Spectrometer (STGS), and discuss exemplary applications, including a design for a double-beam spectrometer without any requirement for a dichroic. This paradigm change in spectrometer design offers an alternative to all-refractive astronomical spectrometer designs, using expensive, fragile lens elements fabricated from CaF2 or even more exotic materials. The unobscured mirror layout avoids a major drawback of the previous generation of catadioptric spectrometer designs. We describe laboratory measurements of the efficiency and image quality of a curved VPH grating in a STGS design, demonstrating, simultaneously, efficiency comparable to planar VPH gratings along with good image quality. The stage is now set for construction of a prototype instrument with impressive performance.

  1. Grand Hotel prijutil hudozhnikov

    2004-01-01

    Raadioajakirjanik Lea Veelmaa lindistas "Kunstikanali" 2004. a. esimese saate Grand Hotel Viljandis. Saatekülaliseks oli maalikunstnik Andres Tolts. Toltsi kaheksa akrüülmaali on eksponeeritud hotelli fuajees ja restoranis

  2. Grand Mal Seizure

    ... grand mal seizures include: A family history of seizure disorders Any injury to the brain from trauma, a ... the risk of birth defects. If you have epilepsy and plan to become pregnant, work with your ...

  3. The SPEDE spectrometer

    Papadakis, P.; Cox, D. M.; O'Neill, G. G.; Borge, M. J. G.; Butler, P. A.; Gaffney, L. P.; Greenlees, P. T.; Herzberg, R.-D.; Illana, A.; Joss, D. T.; Konki, J.; Kröll, T.; Ojala, J.; Page, R. D.; Rahkila, P.; Ranttila, K.; Thornhill, J.; Tuunanen, J.; Van Duppen, P.; Warr, N.; Pakarinen, J.

    2018-03-01

    The electron spectrometer, SPEDE, has been developed and will be employed in conjunction with the Miniball spectrometer at the HIE-ISOLDE facility, CERN. SPEDE allows for direct measurement of internal conversion electrons emitted in-flight, without employing magnetic fields to transport or momentum filter the electrons. Together with the Miniball spectrometer, it enables simultaneous observation of γ rays and conversion electrons in Coulomb excitation experiments using radioactive ion beams.

  4. A gamma scintillation spectrometer

    Symbalisty, S

    1952-07-01

    A scintillation type gamma ray spectrometer employing coincidence counting, designed and built at the Physics Department of the University of Western Ontario is described. The spectrometer is composed of two anthracene and photomultiplier radiation detectors, two pulse analyzing channels, a coincidence stage, three scalers and a high voltage stabilized supply. A preliminary experiment to test the operation of the spectrometer was performed and the results of this test are presented. (author)

  5. Mass spectrometers in medicine

    Bushman, J.A.

    1975-01-01

    This paper describes how the mass spectrometer enables true lung function, namely the exchange of gases between the environment and the organism, to be measured. This has greatly improved the understanding of respiratory disease and the latest generation of respiratory mass spectrometers will do much to increase the application of the technique. (author)

  6. The Omicron Spectrometer

    Allardyce, B W

    1976-01-01

    It is intended to build a spectrometer with a large solid angle and a large momentum acceptance at the reconstructed synchrocyclotron at CERN. This spectrometer will have an energy resolution of about 1 MeV for particles with momenta up to about 400 MeV/c.

  7. The SAGE spectrometer

    Pakarinen, J.; Papadakis, P. [University of Liverpool, Department of Physics, Oliver Lodge Laboratory, Liverpool (United Kingdom); University of Jyvaeskylae, Department of Physics, Jyvaeskylae (Finland); Sorri, J.; Greenlees, P.T.; Jones, P.; Julin, R.; Konki, J.; Rahkila, P.; Sandzelius, M. [University of Jyvaeskylae, Department of Physics, Jyvaeskylae (Finland); Herzberg, R.D.; Butler, P.A.; Cox, D.M.; Cresswell, J.R.; Mistry, A.; Page, R.D.; Parr, E.; Sampson, J.; Seddon, D.A.; Thornhill, J.; Wells, D. [University of Liverpool, Department of Physics, Oliver Lodge Laboratory, Liverpool (United Kingdom); Coleman-Smith, P.J.; Lazarus, I.H.; Letts, S.C.; Pucknell, V.F.E.; Simpson, J. [STFC Daresbury Laboratory, Warrington (United Kingdom)

    2014-03-15

    The SAGE spectrometer has been constructed for in-beam nuclear structure studies. SAGE combines a Ge-detector array and an electron spectrometer for detection of γ-rays and internal conversion electrons, respectively, and allows simultaneous observation of both electrons and γ-rays emitted from excited nuclei. SAGE is set up in the Accelerator Laboratory of the University of Jyvaeskylae and works in conjunction with the RITU gas-filled recoil separator and the GREAT focal-plane spectrometer allowing the use of the recoil-decay tagging method. (orig.)

  8. The SAGE spectrometer

    Pakarinen, J.; Papadakis, P.; Sorri, J.; Greenlees, P.T.; Jones, P.; Julin, R.; Konki, J.; Rahkila, P.; Sandzelius, M.; Herzberg, R.D.; Butler, P.A.; Cox, D.M.; Cresswell, J.R.; Mistry, A.; Page, R.D.; Parr, E.; Sampson, J.; Seddon, D.A.; Thornhill, J.; Wells, D.; Coleman-Smith, P.J.; Lazarus, I.H.; Letts, S.C.; Pucknell, V.F.E.; Simpson, J.

    2014-01-01

    The SAGE spectrometer has been constructed for in-beam nuclear structure studies. SAGE combines a Ge-detector array and an electron spectrometer for detection of γ-rays and internal conversion electrons, respectively, and allows simultaneous observation of both electrons and γ-rays emitted from excited nuclei. SAGE is set up in the Accelerator Laboratory of the University of Jyvaeskylae and works in conjunction with the RITU gas-filled recoil separator and the GREAT focal-plane spectrometer allowing the use of the recoil-decay tagging method. (orig.)

  9. The MEG positron spectrometer

    Nishiguchi, Hajime

    2007-01-01

    We have been developing an innovative spectrometer for the MEG experiment at the Paul Scherrer Institute (PSI) in Switzerland. This experiment searches for a lepton flavour violating decay μ + →e + γ with a sensitivity of 10 -13 in order to explore the region predicted by supersymmetric extensions of the standard model. The MEG positron spectrometer consists of a specially designed superconducting solenoidal magnet with a highly graded field, an ultimate low-mass drift chamber system, and a precise time measuring counter system. This innovative positron spectrometer is described here focusing on the drift chamber system

  10. Democracy and "Grand" Corruption.

    Rose-Ackerman, Susan

    1996-01-01

    Defines "grand" corruption as that occurring at the higher levels of a political system and involving large sums of money. Discusses the impact and incentives for this level of corruption as well as various government responses. Identifies multinational corporations as the major malefactors. (MJP)

  11. The GRANDE detector

    Adams, A.; Bond, R.; Coleman, L.; Rollefson, A.; Wold, D.; Bratton, C.B.; Gurr, H.; Kropp, W.; Nelson, M.; Price, L.R.; Reines, F.; Schultz, J.; Sobel, H.; Svoboda, R.; Yodh, G.; Burnett, T.; Chaloupka, V.; Wilkes, R.J.; Cherry, M.; Ellison, S.B.; Guzik, T.G.; Wefel, J.; Gaidos, J.; Loeffler, F.; Sembroski, G.; Wilson, C.; Goodman, J.; Haines, T.J.; Kielczewska, D.; Lane, C.; Steinberg, R.; Lieber, M.; Nagle, D.; Potter, M.; Tripp, R.

    1990-01-01

    In this paper we present a detector facility which meets the requirements outlined above for a next-generation instrument. GRANDE (Gamma Ray and Neutrino DEtector) is an imaging, water Cerenkov detector, which combines in one facility an extensive air shower array and a high-energy neutrino detector. (orig.)

  12. Triggering the GRANDE array

    Wilson, C.L.; Bratton, C.B.; Gurr, J.; Kropp, W.; Nelson, M.; Sobel, H.; Svoboda, R.; Yodh, G.; Burnett, T.; Chaloupka, V.; Wilkes, R.J.; Cherry, M.; Ellison, S.B.; Guzik, T.G.; Wefel, J.; Gaidos, J.; Loeffler, F.; Sembroski, G.; Goodman, J.; Haines, T.J.; Kielczewska, D.; Lane, C.; Steinberg, R.; Lieber, M.; Nagle, D.; Potter, M.; Tripp, R.

    1990-01-01

    A brief description of the Gamma Ray And Neutrino Detector Experiment (GRANDE) is presented. The detector elements and electronics are described. The trigger logic for the array is then examined. The triggers for the Gamma Ray and the Neutrino portions of the array are treated separately. (orig.)

  13. Grand-Bassam

    Geo

    l'estuaire du fleuve Comoé (Grand-Bassam, Côte d'Ivoire). Kouassi Laurent ADOPO1*, Apie Colette AKOBE1, Etche Mireille AMANI2,. Sylvain MONDE3 et Kouamé AKA3. (1)Laboratoire de Géologie Marine, Sédimentologie et Environnement, Centre de Recherche en Ecologie,. Université Felix Houphouet Boigny Abidjan, ...

  14. Digital positron annihilation spectrometer

    Cheng Bin; Weng Huimin; Han Rongdian; Ye Bangjiao

    2010-01-01

    With the high speed development of digital signal process, the technique of the digitization and processing of signals was applied in the domain of a broad class of nuclear technique. The development of digital positron lifetime spectrometer (DPLS) is more promising than the conventional positron lifetime spectrometer equipped with nuclear instrument modules. And digital lifetime spectrometer has many advantages, such as low noise, long term stability, flexible online or offline digital processing, simple setup, low expense, easy to setting, and more physical information. Digital constant fraction discrimination is for timing. And a new method of optimizing energy windows setting for digital positron lifetime spectrometer is also developed employing the simulated annealing for the convenient use. The time resolution is 220ps and the count rate is 200cps. (authors)

  15. Micro Plasma Spectrometer

    National Aeronautics and Space Administration — The purpose of this IRAD project is to develop a preliminary design elements of miniature electron and ion plasma spectrometers and supporting electronics, focusing...

  16. Fourier Transform Spectrometer System

    Campbell, Joel F. (Inventor)

    2014-01-01

    A Fourier transform spectrometer (FTS) data acquisition system includes an FTS spectrometer that receives a spectral signal and a laser signal. The system further includes a wideband detector, which is in communication with the FTS spectrometer and receives the spectral signal and laser signal from the FTS spectrometer. The wideband detector produces a composite signal comprising the laser signal and the spectral signal. The system further comprises a converter in communication with the wideband detector to receive and digitize the composite signal. The system further includes a signal processing unit that receives the composite signal from the converter. The signal processing unit further filters the laser signal and the spectral signal from the composite signal and demodulates the laser signal, to produce velocity corrected spectral data.

  17. Grand unified theories

    Langacker, P.

    1981-01-01

    In this talk I discuss the present status of these theories and of their observational and experimental implications. In section II, I briefly review the standard SU 3 sup(c) x SU 2 x U 1 model of the strong and electroweak interactions. Although phenomenologically successful, the standard model leaves many questions unanswered. Some of these questions are addressed by grand unified theories, which are defined and discussed in Section III. The Georgi-Glashow SU 5 model is described, as are theories based on larger groups such as SO 10 , E 6 , or SO 16 . It is emphasized that there are many possible grand unified theories and that it is an experimental problem not only to test the basic ideas but to discriminate between models. (orig./HSI)

  18. Asymptotically safe grand unification

    Bajc, Borut [J. Stefan Institute,1000 Ljubljana (Slovenia); Sannino, Francesco [CP-Origins & the Danish IAS, University of Southern Denmark,Campusvej 55, DK-5230 Odense M (Denmark); Université de Lyon, France, Université Lyon 1, CNRS/IN2P3, UMR5822 IPNL,F-69622 Villeurbanne Cedex (France)

    2016-12-28

    Phenomenologically appealing supersymmetric grand unified theories have large gauge representations and thus are not asymptotically free. Their ultraviolet validity is limited by the appearance of a Landau pole well before the Planck scale. One could hope that these theories save themselves, before the inclusion of gravity, by generating an interacting ultraviolet fixed point, similar to the one recently discovered in non-supersymmetric gauge-Yukawa theories. Employing a-maximization, a-theorem, unitarity bounds, as well as positivity of other central charges we nonperturbatively rule out this possibility for a broad class of prime candidates of phenomenologically relevant supersymmetric grand unified theories. We also uncover candidates passing these tests, which have either exotic matter or contain one field decoupled from the superpotential. The latter class of theories contains a model with the minimal matter content required by phenomenology.

  19. LA GRANDE DESCENTE

    The first endcap disc of CMS being lowered slowly and carefully 100 m underground into the experimental cavern. The disc is one of 15 large pieces to make the grand descent.  The uniquely shaped slice, 16 m high, about 50 cm thick weighs 400 tonnes. The two HF that were lowered earlier in November can also be seen in the foreground and background.  

  20. Ultralow background germanium gamma-ray spectrometer using superclean materials and cosmic-ray anticoincidence

    Reeves, J.H.; Hensley, W.K.; Brodzinski, R.L.; Ryge, P.

    1983-10-01

    Efforts to measure the double beta decay of 76 Ge as predicted by Grand Unified Theories have resulted in the development of a high resolution germanium diode gamma-ray spectrometer with an exceptionally low background. This paper describes the development of this system and how these techniques can be utilized to significantly reduce the background in high resolution photon spectrometers at only a moderate cost

  1. Grande do Sul, Brasil

    Denis Alcides-Rezende

    2008-01-01

    Full Text Available The objective of this work is to analyse the integration of information systems and information technology resources in the municipal planning of 14 small cities of Rio Grande do Sul (Brazil. The research methodology consisted of a multiple case study together with a convenient non-probabilistic sample chosen through a research protocol. The results demonstrate the difficulties of these cities to organise the municipal data as well as their struggle for accessibility of information and planning for management and control.

  2. Cyclotrons as mass spectrometers

    Clark, D.J.

    1984-04-01

    The principles and design choices for cyclotrons as mass spectrometers are described. They are illustrated by examples of cyclotrons developed by various groups for this purpose. The use of present high energy cyclotrons for mass spectrometry is also described. 28 references, 12 figures

  3. Miniature Raman spectrometer development

    Bonvallet, Joseph; Auz, Bryan; Rodriguez, John; Olmstead, Ty

    2018-02-01

    The development of techniques to rapidly identify samples ranging from, molecule and particle imaging to detection of high explosive materials, has surged in recent years. Due to this growing want, Raman spectroscopy gives a molecular fingerprint, with no sample preparation, and can be done remotely. These systems can be small, compact, lightweight, and with a user interface that allows for easy use and sample identification. Ocean Optics Inc. has developed several systems that would meet all these end user requirements. This talk will describe the development of different Ocean Optics Inc miniature Raman spectrometers. The spectrometer on a phone (SOAP) system was designed using commercial off the shelf (COTS) components, in a rapid product development cycle. The footprint of the system measures 40x40x14 mm (LxWxH) and was coupled directly to the cell phone detector camera optics. However, it gets roughly only 40 cm-1 resolution. The Accuman system is the largest (290x220X100 mm) of the three, but uses our QEPro spectrometer and get 7-11 cm-1 resolution. Finally, the HRS-30 measuring 165x85x40 mm is a combination of the other two systems. This system uses a modified EMBED spectrometer and gets 7-12 cm-1 resolution. Each of these units uses a peak matching algorithm that then correlates the results to the pre-loaded and customizable spectral libraries.

  4. Microprocessor monitored Auger spectrometer

    Sapin, Michel; Ghaleb, Dominique; Pernot, Bernard.

    1982-05-01

    The operation of an Auger spectrometer, used for studying surface impurity diffusion, has been fully automatized with the help of a microprocessor. The characteristics, performance and practical use of the system are described together with the main advantage for the experimentator [fr

  5. The Omega spectrometer

    1972-01-01

    The Omega spectrometer which came into action during the year. An array of optical spark chambers can be seen withdrawn from the magnet aperture. In the 'igloo' above the magnet is located the Plumbicon camera system which collects information from the spark chambers.

  6. Heat of vaporization spectrometer

    Edwards, D. Jr.

    1978-01-01

    Multilayer desorption measurements of various substances adsorbed on a stainless steel substrate are found to exhibit desorption profiles consistent with a zeroth order desorption model. The singleness of the desorption transients together with their narrow peak widths makes the technique ideally suited for a heat of vaporization spectrometer for either substance analysis or identification

  7. Speckle-based spectrometer

    Chakrabarti, Maumita; Jakobsen, Michael Linde; Hanson, Steen Grüner

    2015-01-01

    A novel spectrometer concept is analyzed and experimentally verified. The method relies on probing the speckle displacement due to a change in the incident wavelength. A rough surface is illuminated at an oblique angle, and the peak position of the covariance between the speckle patterns observed...

  8. Electron volt neutron spectrometers

    Pietropaolo, A.; Senesi, R.

    2011-01-01

    The advent of pulsed neutron sources has made available intense fluxes of epithermal neutrons (500 meV ≤E≤100 eV ). The possibility to open new investigations on condensed matter with eV neutron scattering techniques, is related to the development of methods, concepts and devices that drive, or are inspired by, emerging studies at this energy scale. Electron volt spectrometers have undergone continuous improvements since the construction of the first prototype instruments, but in the last decade major breakthroughs have been accomplished in terms of resolution and counting statistics, leading, for example, to the direct measurement of the proton 3-D Born–Oppenheimer potential in any material, or to quantitatively probe nuclear quantum effects in hydrogen bonded systems. This paper reports on the most effective methods and concepts for energy analysis and detection, as well as devices for the optimization of electron volt spectrometers for different applications. This is set in the context of the progress made up to date in instrument development. Starting from early stages of development of the technique, particular emphasis will be given to the Vesuvio eV spectrometer at the ISIS neutron source, the first spectrometer where extensive scientific, as well as research and development programmes have been carried out. The potential offered by this type of instrumentation, from single particle excitations to momentum distribution studies, is then put in perspective into the emerging fields of eV spectroscopy applied to cultural heritages and neutron irradiation effects in electronics. - Highlights: ► Neutron spectrometers at eV energies. ► Methods and techniques for eV neutrons counting at spallation sources. ► Scattering, imaging and radiation hardness tests with multi-eV neutrons.

  9. Wide band ENDOR spectrometer

    Mendonca Filho, C.

    1973-01-01

    The construction of an ENDOR spectrometer operating from 0,5 to 75 MHz within a single band, with ore Klystron and homodine detection, and no fundamental changes on the electron spin resonance spectrometer was described. The ENDOR signal can be detected both by amplitude modulation of the frequency field, or direct detection of the ESR output, which is taken to a signal analyser. The signal-to-noise ratio is raised by averaging rather than filtering avoiding the use of long time constants, providing natural line widths. The experimental apparatus and the spectra obtained are described. A discussion, relating the ENDOR line amplitudes with the experimental conditions is done and ENDOR mechanism, in which there is a relevant presence of cross relaxation is proposed

  10. The OPERA magnetic spectrometer

    Ambrosio, M; Dusini, S; Dulach, B; Fanin, C; Felici, G; Corso, F D; Garfagnini, A; Grianti, F; Gustavino, C; Monacelli, P; Paoloni, A; Stanco, L; Spinetti, M; Terranova, F; Votano, L

    2004-01-01

    The OPERA neutrino oscillation experiment foresees the construction of two magnetized iron spectrometers located after the lead-nuclear emulsion targets. The magnet is made up of two vertical walls of rectangular cross section connected by return yokes. The particle trajectories are measured by high precision drift tubes located before and after the arms of the magnet. Moreover, the magnet steel is instrumented with Resistive Plate Chambers that ease pattern recognition and allow a calorimetric measurement of the hadronic showers. In this paper we review the construction of the spectrometers. In particular, we describe the results obtained from the magnet and RPC prototypes and the installation of the final apparatus at the Gran Sasso laboratories. We discuss the mechanical and magnetic properties of the steel and the techniques employed to calibrate the field in the bulk of the magnet. Moreover, results of the tests and issues concerning the mass production of the Resistive Plate Chambers are reported. Final...

  11. ALICE photon spectrometer crystals

    Maximilien Brice

    2006-01-01

    Members of the mechanical assembly team insert the last few crystals into the first module of ALICE's photon spectrometer. These crystals are made from lead-tungstate, a crystal as clear as glass but with nearly four times the density. When a high-energy particle passes through one of these crystals it will scintillate, emitting a flash of light allowing the energy of photons, electrons and positrons to be measured.

  12. Magnetic spectrometer control system

    Lecca, L.A.; Di Paolo, Hugo; Fernandez Niello, Jorge O.; Marti, Guillermo V; Pacheco, Alberto J.; Ramirez, Marcelo

    2003-01-01

    The design and implementation of a new computerized control system for the several devices of the magnetic spectrometer at TANDAR Laboratory is described. This system, as a main difference from the preexisting one, is compatible with almost any operating systems of wide spread use available in PC. This allows on-line measurement and control of all signals from any terminal of a computer network. (author)

  13. Polarized neutron spectrometer

    Abov, Yu.G.; Novitskij, V.V.; Alfimenkov, V.P.; Galinskij, E.M.; Mareev, Yu.D.; Pikel'ner, L.B.; Chernikov, A.N.; Lason', L.; Tsulaya, V.M.; Tsulaya, M.I.

    2000-01-01

    The polarized neutron spectrometer, intended for studying the interaction of polarized neutrons with nuclei and condensed media in the area of energies from thermal up to several electron-volt, is developed at the IBR-2 reactor (JINR, Dubna). Diffraction on the Co(92%)-Fe(8%) magnetized monocrystals is used for the neutron polarization and polarization analysis. The neutron polarization within the whole energy range equals ∼ 95% [ru

  14. Grand unification and supergravity

    Nanopoulos, D.V.

    Grand Unified Theories (GUTs) are very successful, but they suffer from fine-tuning or hierarchy problems. It seems that more symmetry beyond the gauge symmetry is needed and indeed supersymmetric GUTs may provide the correct framework in solving the hierarchy problems. These are reviewed. From the results discussed, it is seen that for the first time in particle physics, gravity seems to play a dominant role. It may be responsible for GUT breaking, SU(2) x U(1) breaking, fermion masses, proton decay and a consistent cosmological picture. Supergravity seems to offer a consistent, effective theory for energies below the Planck scale to N=1 local SUSY but also, in the context of N=8 extended supergravity with a dynamically realized SU(8), there may be a consistent fundamental unified theory of all interactions. (U.K.)

  15. Grand unification: status report

    Georgi, H.

    1983-01-01

    Grand unification is reviewed with regard to the flavor puzzle and the hierarchy puzzle. Progress in CP and the PQWWKDFS axion is reviewed. The neutrino mass and B-L research, the understanding and assimilation of the language of effective theories (which divide the momentum scale up into regions), with focus on the models, are surveyed. Various unified models are organized according to whether they address the hierarchy puzzle or the flavor puzzle. SU(5), SO(10), E6, and Higgs are considered simple and explicit models. Global symmetry addresses hierarchy puzzle, but the rules are unclear. In SO (18), with regard to hierarchy, perturbation theory breaks down. SO (14) fails for hierarchy because of GIM, b and t problems. Supersymmetry and technicolor with regard to flavor puzzle are questioned. The CP solution of ETC and Composite C models (addressing both flavor and hierarchy) is a minus. Composite A model has no evident virtues, and the basic idea of ETC model needs checking

  16. Development of Neutron Spectrometer

    Lee, Chang Hee; Lee, J. S.; Seong, B. S. (and others)

    2007-06-15

    Neutron spectrometers which are used in the basic researches such as physics, chemistry and materials science and applied in the industry were developed at the horizontal beam port of HANARO reactor. In addition, the development of core components for neutron scattering and the upgrade of existing facilities are also performed. The vertical neutron reflectometer was fabricated and installed at ST3 beam port. The performance test of the reflectometer was completed and the reflectometer was opened to users. The several core parts and options were added in the polarized neutron spectrometer. The horizontal neutron reflectometer from Brookhaven National Laboratory was moved to HANARO and installed, and the performance of the reflectometer was examined. The HIPD was developed and the performance test was completed. The base shielding for TAS was fabricated. The soller collimator, Cu mosaic monochromator, Si BPC monochromator and position sensitive detector were developed and applied in the neutron spectrometer as part of core component development activities. In addition, the sputtering machine for mirror device are fabricated and the neutron mirror is made using the sputtering machine. The FCD was upgraded and the performance of the FCD are improved over the factor of 10. The integration and upgrade of the neutron detection system were also performed.

  17. Grand unified theories. Pt. 2

    Ellis, J.

    1982-01-01

    The author gives an introduction to the construction of grand unified theories on the base of the SU(3)xSU(2)xU(1) model of the strong, weak, and electromagnetic interactions. Especially he discusses the proton decay, neutrino masses and oscillations, and cosmological implications in connection with grand unified theories. (orig./HSI)

  18. La importancia de ser grande

    Baisre, J. A.

    2007-01-01

    Se responde a las preguntas ¿por qué los mamíferos marinos son los animales más grandes del planeta?, ¿Por qué los peces no pueden ser más grandes?. Éstas y otras interrogantes son respondidas de forma sencilla y clara.

  19. Triple axis spectrometers

    Clausen, K.N.

    1997-01-01

    Conventional triple-axis neutron spectroscopy was developed by Brockhouse over thirty years ago' and remains today a versatile and powerful tool for probing the dynamics of condensed matter. The original design of the triple axis spectrometer is technically simple and probes momentum and energy space on a point-by-point basis. This ability to systematically probe the scattering function in a way which only requires a few angles to be moved under computer control and where the observed data in general can be analysed using a pencil and graph paper or a simple fitting routine, has been essential for the success of the method. These constraints were quite reasonable at the time the technique was developed. Advances in computer based data acquisition, neutron beam optics, and position sensitive area detectors have been gradually implemented on many triple axis spectrometer spectrometers, but the full potential of this has not been fully exploited yet. Further improvement in terms of efficiency (beyond point by point inspection) and increased sensitivity (use of focusing optics whenever the problem allows it) could easily be up to a factor of 10-20 over present instruments for many problems at a cost which is negligible compared to that of increasing the flux of the source. The real cost will be in complexity - finding the optimal set-up for a given scan and interpreting the data as the they are taken. On-line transformation of the data for an appropriate display in Q, ω space and analysis tools will be equally important for this task, and the success of these new ideas will crucially depend on how well we solve these problems. (author)

  20. A superconducting electron spectrometer

    Guttormsen, M.; Huebel, H.; Grumbkow, A. von

    1983-03-01

    The set-up and tests of an electron spectrometer for in-beam conversion electron measurements are described. A superconducting solenoid is used to transport the electrons from the target to cooled Si(Li) detectors. The solenoid is designed to produce either a homogeneous axially symmetric field of up to 2 Tesla or a variety of field profiles by powering the inner and outer set of coils of the solenoid separately. The electron trajectories resulting for various field profiles are discussed. In-beam electron spectra taken in coincidence with electrons, gammas and alpha-particles are shown. (Auth.)

  1. Intermediate PT jet spectrometers

    Gutay, L.J.; Koltick, D.; Hauptman, J.; Stork, D.; Theodosiou, G.

    1988-01-01

    A design is presented for a limited solid angle, high resolution double arm spectrometer at 90 degree to the begin, with a vertex detector and particle identification in both arms. The jet arm is designed to accept a complete jet, and identify its substructure of sub-jets, hadrons, and leptons. The particle arm would measure e,π,K,p ratios for P T 0 to the beam for the purpose of tagging Higgs production by boson fusion, 1 gauge boson (WW, ZZ, and WZ) scattering 2 L, and other processes involving the interactions of virtual gauge bosons

  2. HISS spectrometer at LBL

    Greiner, D.

    1980-11-01

    The Heavy Ion Spectrometer System at LBL is designed to be a general purpose experimental work bench able to support a wide variety of experiments. Our philosophy is to provide instruments capable of investigating, with multi-particle sensitivity, a large portion of phase space. We have not chosen a particular region such as mid-rapidity or projectile frame but, instead, have made sure that the magnet and the instrumentation allow these choices as well as many others. The beam can be brought into the magnet at a variable position and the magnet can be rotated

  3. Gas Chromatic Mass Spectrometer

    Wey, Chowen

    1995-01-01

    Gas chromatograph/mass spectrometer (GC/MS) used to measure and identify combustion species present in trace concentration. Advanced extractive diagnostic method measures to parts per billion (PPB), as well as differentiates between different types of hydrocarbons. Applicable for petrochemical, waste incinerator, diesel transporation, and electric utility companies in accurately monitoring types of hydrocarbon emissions generated by fuel combustion, in order to meet stricter environmental requirements. Other potential applications include manufacturing processes requiring precise detection of toxic gaseous chemicals, biomedical applications requiring precise identification of accumulative gaseous species, and gas utility operations requiring high-sensitivity leak detection.

  4. Grand slam on cancer.

    Gartrell, Nanette

    2014-01-01

    A winner of 59 Grand Slam championships including a record 9 Wimbledon singles titles, Martina Navratilova is the most successful woman tennis player of the modern era. Martina was inducted into the International Tennis Hall of Fame, named "Tour Player of the Year" seven times by the Women's Tennis Association, declared "Female Athlete of the Year" by the Associated Press, and ranked one of the "Top Forty Athletes of All-Time" by Sports Illustrated. Equally accomplished off the court, Martina is an author, philanthropist, TV commentator, and activist who has dedicated her life to educating people about prejudice and stereotypes. After coming out as a lesbian in 1981, Martina became a tireless advocate of equal rights for lesbian, gay, bisexual, and transgender (LGBT) people, and she has contributed generously to the LGBT community. Martina is the author of seven books, including most recently Shape Your Self: My 6-Step Diet and Fitness Plan to Achieve the Best Shape of your Life, an inspiring guide to healthy living and personal fitness. Martina was diagnosed with breast cancer in 2010.

  5. Clinical physiology grand rounds.

    Richards, Jeremy; Schwartzstein, Richard; Irish, Julie; Almeida, Jacqueline; Roberts, David

    2013-04-01

    Clinical Physiology Grand Rounds (CPGR) is an interactive, case-based conference for medical students designed to: (1) integrate preclinical and clinical learning; (2) promote inductive clinical reasoning; and (3) emphasise students as peer teachers. CPGR specifically encourages mixed learning level student interactions and emphasises the use of concept mapping. We describe the theoretical basis and logistical considerations for an interactive, integrative, mixed-learner environment such as CPGR. In addition, we report qualitative data regarding students' attitudes towards and perceptions of CPGR. Medical students from first to fourth year participate in a monthly, interactive conference. The CPGR was designed to bridge gaps and reinforce linkages between basic science and clinical concepts, and to incorporate interactive vertical integration between preclinical and clinical students. Medical education and content experts use Socratic, interactive teaching methods to develop real-time concept maps to emphasise the presence and importance of linkages across curricula. Student focus groups were held to assess attitudes towards and perceptions of the mixed-learner environment and concept maps in CPGR. Qualitative analyses of focus group transcripts were performed to develop themes and codes describing the students' impressions of CPGR. CPGR is a case-based, interactive conference designed to help students gain an increased appreciation of linkages between basic science and clinical medicine concepts, and an increased awareness of clinical reasoning thought processes. Success is dependent upon explicit attention being given to goals for students' integrated learning. © Blackwell Publishing Ltd 2013.

  6. Resonant ultrasound spectrometer

    Migliori, Albert; Visscher, William M.; Fisk, Zachary

    1990-01-01

    An ultrasound resonant spectrometer determines the resonant frequency spectrum of a rectangular parallelepiped sample of a high dissipation material over an expected resonant response frequency range. A sample holder structure grips corners of the sample between piezoelectric drive and receive transducers. Each transducer is mounted on a membrane for only weakly coupling the transducer to the holder structure and operatively contacts a material effective to remove system resonant responses at the transducer from the expected response range. i.e., either a material such as diamond to move the response frequencies above the range or a damping powder to preclude response within the range. A square-law detector amplifier receives the response signal and retransmits the signal on an isolated shield of connecting cabling to remove cabling capacitive effects. The amplifier also provides a substantially frequency independently voltage divider with the receive transducer. The spectrometer is extremely sensitive to enable low amplitude resonance to be detected for use in calculating the elastic constants of the high dissipation sample.

  7. Prototype Neutron Energy Spectrometer

    Mitchell, Stephen; Mukhopadhyay, Sanjoy; Maurer, Richard; Wolff, Ronald

    2010-01-01

    The project goals are: (1) Use three to five pressurized helium tubes with varying polyethylene moderators to build a neutron energy spectrometer that is most sensitive to the incident neutron energy of interest. Neutron energies that are of particular interest are those from the fission neutrons (typically around 1-2 MeV); (2) Neutron Source Identification - Use the neutron energy 'selectivity' property as a tool to discriminate against other competing processes by which neutrons are generated (viz. Cosmic ray induced neutron production (ship effect), (a, n) reactions); (3) Determine the efficiency as a function of neutron energy (response function) of each of the detectors, and thereby obtain the composite neutron energy spectrum from the detector count rates; and (4) Far-field data characterization and effectively discerning shielded fission source. Summary of the presentation is: (1) A light weight simple form factor compact neutron energy spectrometer ready to be used in maritime missions has been built; (2) Under laboratory conditions, individual Single Neutron Source Identification is possible within 30 minutes. (3) Sources belonging to the same type of origin viz., (a, n), fission, cosmic cluster in the same place in the 2-D plot shown; and (4) Isotopes belonging to the same source origin like Cm-Be, Am-Be (a, n) or Pu-239, U-235 (fission) do have some overlap in the 2-D plot.

  8. Prototype Neutron Energy Spectrometer

    Stephen Mitchell, Sanjoy Mukhopadhyay, Richard Maurer, Ronald Wolff

    2010-06-16

    The project goals are: (1) Use three to five pressurized helium tubes with varying polyethylene moderators to build a neutron energy spectrometer that is most sensitive to the incident neutron energy of interest. Neutron energies that are of particular interest are those from the fission neutrons (typically around 1-2 MeV); (2) Neutron Source Identification - Use the neutron energy 'selectivity' property as a tool to discriminate against other competing processes by which neutrons are generated (viz. Cosmic ray induced neutron production [ship effect], [a, n] reactions); (3) Determine the efficiency as a function of neutron energy (response function) of each of the detectors, and thereby obtain the composite neutron energy spectrum from the detector count rates; and (4) Far-field data characterization and effectively discerning shielded fission source. Summary of the presentation is: (1) A light weight simple form factor compact neutron energy spectrometer ready to be used in maritime missions has been built; (2) Under laboratory conditions, individual Single Neutron Source Identification is possible within 30 minutes. (3) Sources belonging to the same type of origin viz., (a, n), fission, cosmic cluster in the same place in the 2-D plot shown; and (4) Isotopes belonging to the same source origin like Cm-Be, Am-Be (a, n) or Pu-239, U-235 (fission) do have some overlap in the 2-D plot.

  9. The SPEDE electron spectrometer

    O'Neill, George

    This thesis presents SPEDE (SPectrometer for Electron DEtection) and documents its construction, testing and performance during commissioning at Jyvaskyla, Finland, before deployment at the HIE-ISOLDE facility at CERN coupled with the MINIBALL array to perform in-beam electron-gamma spectroscopy using post-accelerated radioactive ion beams. Commissioning experiments took place in two two-day stints during spring 2015, coupled with several JUROGAMII gamma-detectors. This spectrometer will help aid in fully understanding exotic regions of the nuclear chart such as regions with a high degree of octupole deformation, and in those nuclei exhibiting shape coexistence. For the rst time, electron spectroscopy has been performed at the target position from states populated in accelerated nuclei via Coulomb excitation. The FWHM of SPEDE is approximately 7 keV at 320 keV, and Doppler correction was possible to improve Doppler broadened peaks. The results are intended to give the reader a full understanding of the dete...

  10. Simulation of the SAGE spectrometer

    Cox, D.M.; Herzberg, R.D. [University of Liverpool, Department of Physics, Oliver Lodge Laboratory, Liverpool (United Kingdom); Konki, J.; Greenlees, P.T.; Pakarinen, J.; Papadakis, P.; Rahkila, P.; Sandzelius, M.; Sorri, J. [University of Jyvaeskylae, Department of Physics, Jyvaeskylae (Finland); Hauschild, K. [Universite Paris-Sud, CSNSM-IN2P3-CNRS, Orsay (France)

    2015-06-15

    The SAGE spectrometer combines a Ge-detector array with a Si detector to allow simultaneous detection of γ-rays and electrons. A comprehensive GEANT4 simulation package of the SAGE spectrometer has been developed with the ability to simulate the expected datasets based on user input files. The measured performance of the spectrometer is compared to the results obtained from the simulations. (orig.)

  11. Simulation of the SAGE spectrometer

    Cox, D.M.; Herzberg, R.D.; Konki, J.; Greenlees, P.T.; Pakarinen, J.; Papadakis, P.; Rahkila, P.; Sandzelius, M.; Sorri, J.; Hauschild, K.

    2015-01-01

    The SAGE spectrometer combines a Ge-detector array with a Si detector to allow simultaneous detection of γ-rays and electrons. A comprehensive GEANT4 simulation package of the SAGE spectrometer has been developed with the ability to simulate the expected datasets based on user input files. The measured performance of the spectrometer is compared to the results obtained from the simulations. (orig.)

  12. LADEE Neutral Mass Spectrometer Data

    National Aeronautics and Space Administration — This bundle contains the data collected by the Neutral Mass Spectrometer (NMS) instrument aboard the Lunar Atmosphere and Dust Environment Explorer (LADEE)...

  13. BNL multiparticle spectrometer software

    Saulys, A.C.

    1984-01-01

    This paper discusses some solutions to problems common to the design, management and maintenance of a large high energy physics spectrometer software system. The experience of dealing with a large, complex program and the necessity of having the program controlled by various people at different levels of computer experience has led us to design a program control structure of mnemonic and self-explanatory nature. The use of this control language in both on-line and off-line operation of the program will be discussed. The solution of structuring a large program for modularity so that substantial changes to the program can be made easily for a wide variety of high energy physics experiments is discussed. Specialized tools for this type of large program management are also discussed

  14. A Moessbauer effect spectrometer

    Fayek, M.K.; Abbas, Y.M.; Bahgat, A.A.

    1983-01-01

    A Moessbauer effect spectrometer of Harwell type is installed and put in operation. The driving system is of a constant acceleration mode with a velocity range 40mm/sec. and associated to a 1024 multichannel analyser working in a multiscalar time mode. The gamma ray sources are 50 mCi Co 57 in Pd and 20 mCi Snsup(119m) in Ba Sn(O) 3 . Measurements are taken with the source kept at room temperature, while the absorber can be maintained at various temperatures. Gamma ray resonance spectra of different standard samples are obtained. Zero velocity and magnetic field calibration curves are deduced. Examples of some Moessbauer spectra for running investigated materials with a comprehensive general description are also given

  15. The Philippine spectrometer

    Juliano, J.O.

    1965-01-01

    A notable project for international collaboration, in which participants from Indonesia, Korea, Thailand, China and the Philippines are working together, has been launched in the Philippines with Indian assistance under the aegis of the Agency. This is a regional training and research programme using a neutron crystal spectrometer, which has been established since January 1965 at the Philippine Atomic Research Centre in Diliman, Quezon City, Philippines. It is called the IPA Project after the signatories to a five year trilateral agreement, namely, the Government of India,the Republic of the Philippines, and the International Atomic Energy Agency. The programme is administered by a Joint Committee composed of one representative each of the Philippines, India and the Agency. The objective of this cooperative venture is to establish a research centre on neutron diffraction in which scientists and technicians from any Member State of IAEA in South Asia, South-East Asia and Pacific, or Far East regions could come to participate in research and training. Studies in solid state physics, such a s the structure determination of alloys and organic crystals, studies on the orientation of magnetic moments in the lattice of magnetic substances, and other problems based on elastic and inelastic scattering of neutrons are undertaken. There are a number of research reactors in this region where neutron spectrometers can be utilized and the recent establishment of this cooperative international research and training programme has been a timely one for this area of the world. Indeed, a number of other countries have shown a strong growing interest in the development of the project

  16. MEMS based digital transform spectrometers

    Geller, Yariv; Ramani, Mouli

    2005-09-01

    Earlier this year, a new breed of Spectrometers based on Micro-Electro-Mechanical-System (MEMS) engines has been introduced to the commercial market. The use of these engines combined with transform mathematics, produces powerful spectrometers at unprecedented low cost in various spectral regions.

  17. General structure of the GRAND program for analysis of the data from a neutrino detector

    Zhigunov, V.P.; Kulikov, V.A.; Mukhin, S.A.; Naumov, V.L.; Platonov, V.G.; Spiridonov, A.A.

    1985-01-01

    The general structure of the GRAND (Global Result Analysis for Neutrino Detector) program used for geometrical and kinematic reconstruction of events recorded by a neutrino detector is considered. The detector consists of a calorimeter-target, a shower electron and γ detector and a magnetic spectrometer. While developing the GRAND program the multivariance (different types of the computers used), availability of various algorithms for solving the same problem, solution of separate particlular problems within the frames of one program are taken into account. The KERNLIB library and the HBOOK, ZBOOK, EPIO and FFREAD subroutine packages are used while creating the program as basic libraries

  18. VEGAS: VErsatile GBT Astronomical Spectrometer

    Bussa, Srikanth; VEGAS Development Team

    2012-01-01

    The National Science Foundation Advanced Technologies and Instrumentation (NSF-ATI) program is funding a new spectrometer backend for the Green Bank Telescope (GBT). This spectrometer is being built by the CICADA collaboration - collaboration between the National Radio Astronomy Observatory (NRAO) and the Center for Astronomy Signal Processing and Electronics Research (CASPER) at the University of California Berkeley.The backend is named as VErsatile GBT Astronomical Spectrometer (VEGAS) and will replace the capabilities of the existing spectrometers. This backend supports data processing from focal plane array systems. The spectrometer will be capable of processing up to 1.25 GHz bandwidth from 8 dual polarized beams or a bandwidth up to 10 GHz from a dual polarized beam.The spectrometer will be using 8-bit analog to digital converters (ADC), which gives a better dynamic range than existing GBT spectrometers. There will be 8 tunable digital sub-bands within the 1.25 GHz bandwidth, which will enhance the capability of simultaneous observation of multiple spectral transitions. The maximum spectral dump rate to disk will be about 0.5 msec. The vastly enhanced backend capabilities will support several science projects with the GBT. The projects include mapping temperature and density structure of molecular clouds; searches for organic molecules in the interstellar medium; determination of the fundamental constants of our evolving Universe; red-shifted spectral features from galaxies across cosmic time and survey for pulsars in the extreme gravitational environment of the Galactic Center.

  19. Respiratory mass spectrometer

    Mostert, J.W. (Pretoria Univ. (South Africa). Dept. of Anesthesiology)

    1983-06-01

    The high degree of technical perfection of the respiratory mass spectrometer has rendered the instrument feasible for routine monitoring of anesthetized patients. It is proposed that the difference between inspired and expired oxygen tension in mm Hg be equated with whole body oxygen consumption in ml/min/M/sup 2/ body-surface area at STPD, by the expedient of multiplying tension-differences by a factor of 2. Years of experience have confirmed the value of promptly recognizing sudden drops in this l/E tension difference below 50 mm Hg indicative of metabolic injury from hypovolemia or respiratory depression. Rises in l/E tension-differences were associated with shivering as well as voluntary muscle activity. Tension differences of less than 25 mm Hg (equated with a whole-body O/sub 2/ consumption of less than 50 ml O/sub 2//min/M/sup 2/) occurred in a patient in the sitting position for posterior fossa exploration without acidosis, hypoxia or hypotension for several hours prior to irreversible cardiac arrest. The value of clinical monitoring by mass spectrometry is especially impressive in open-heart surgery.

  20. The respiratory mass spectrometer

    Mostert, J.W.

    1983-01-01

    The high degree of technical perfection of the respiratory mass spectrometer has rendered the instrument feasible for routine monitoring of anesthetized patients. It is proposed that the difference between inspired and expired oxygen tension in mm Hg be equated with whole body oxygen consumption in ml/min/M 2 body-surface area at STPD, by the expedient of multiplying tension-differences by a factor of 2. Years of experience have confirmed the value of promptly recognizing sudden drops in this l/E tension difference below 50 mm Hg indicative of metabolic injury from hypovolemia or respiratory depression. Rises in l/E tension-differences were associated with shivering as well as voluntary muscle activity. Tension differences of less than 25 mm Hg (equated with a whole-body O 2 consumption of less than 50 ml O 2 /min/M 2 ) occurred in a patient in the sitting position for posterior fossa exploration without acidosis, hypoxia or hypotension for several hours prior to irreversible cardiac arrest. The value of clinical monitoring by mass spectrometry is especially impressive in open-heart surgery

  1. UCN gravitational spectrometer

    Kawabata, Yuji

    1988-01-01

    Concept design is carried out of two types of ultra cold neutron scallering equipment using the fall-focusing principle. One of the systems comprises a vertical gravitational spectrometer and the other includes a horizontal gravitation analyzer. A study is made of their performance and the following results are obtained. Fall-focusing type ultra cold neutron scattering equipment can achieve a high accuracy for measurement of energy and momentum. Compared with conventional neutron scattering systems, this type of equipment can use neutron very efficiently because scattered neutrons within a larger solid angle can be used. The maximum solid angle is nearly 4π and 2π for the vertical and horizontal type, respectively. Another feature is that the size of equipment can be reduced. In the present concept design, the equipment is spherical with a diameter of about 1 m, as compared with NESSIE which is 6.7 m in length and 4.85 m in height with about the same accuracy. Two horizontal analyzers and a vertical spectroscope are proposed. They are suitable for angle-dependent non-elastic scattering in the neutron velocity range of 6∼15 m/s, pure elastic scattering in the range of 4∼7 m/s, or angle-integration non-elastic scattering in the range of 4∼15 m/s. (N.K.)

  2. Software for mass spectrometer control

    Curuia, Marian; Culcer, Mihai; Anghel, Mihai; Iliescu, Mariana; Trancota, Dan; Kaucsar, Martin; Oprea, Cristiana

    2004-01-01

    The paper describes a software application for the MAT 250 mass spectrometer control, which was refurbished. The spectrometer was bring-up-to-date using a hardware structure on its support where the software application for mass spectrometer control was developed . The software application is composed of dedicated modules that perform given operations. The instructions that these modules have to perform are generated by a principal module. This module makes possible the change of information between the modules that compose the software application. The use of a modal structure is useful for adding new functions in the future. The developed application in our institute made possible the transformation of the mass spectrometer MAT 250 into a device endowed with other new generation tools. (authors)

  3. The Lise spectrometer at Ganil

    Saint-Laurent, M.G.

    1986-08-01

    The doubly achromatic spectrometer LISE is available at the french national heavy ion accelerator GANIL. Experimental results, obtained in radioactive beam production and search for new exotic nuclei are briefly reported

  4. Elements of Tiny Plasma Spectrometers

    National Aeronautics and Space Administration — We propose to advance major elements of a miniaturized plasma spectrometer for flight on future missions. This type of instrument has been developed and successfully...

  5. Frequency-Modulation Correlation Spectrometer

    Margolis, J. S.; Martonchik, J. V.

    1985-01-01

    New type of correlation spectrometer eliminates need to shift between two cells, one empty and one containing reference gas. Electrooptical phase modulator sinusoidally shift frequencies of sample transmission spectrum.

  6. Electron spectrometers with internal conversion

    Suita, J.C.; Lemos Junior, O.F.; Auler, L.T.; Silva, A.G. da

    1981-01-01

    The efforts that the Department of Physics (DEFI) of Institute of Nuclear Engineering (IEN) are being made aiming at adjusting the electron spectrometers with internal conversion to its necessity, are shown. (E.G.) [pt

  7. Selected topics in grand unification

    Seckel, D.

    1983-01-01

    This dissertation is a collection of four pieces of research dealing with grand unification. The topics are neutron oscillation, CP violation, magnetic monopole abundance and distribution in neutron stars, and a proposal for an inflationary cosmology driven by stress-energy in domain walls

  8. Introduction to grand unification theories

    Kang, Kyungsik

    1980-01-01

    We introduce the Georgi-Glashow model based on the minimal gauge group SU(5) as a prototype grand unification theory of the electroweak and strong interactions. Simple estimation of sin 2 thetasub(W) in the symmetry limit and the renormalization corrections at the energy scale of Msub(W) are given along wich other successes of the SU(5) model

  9. Coordinated Exploration for Grand Challenges

    Ørding Olsen, Anders; Sofka, Wolfgang; Grimpe, Christoph

    2016-01-01

    Grand challenges are among the most complex problems for modern societies. Many governments and foundations provide substantial resources to encourage the search for solutions. Due to the significance of these problems, organizations often form partnerships in what we call search consortia to eng...

  10. Results from KASCADE–Grande

    Bertaina, M.; Apel, W.D.; Arteaga-Velázquez, J.C.; Bekk, K.; Blümer, J.; Bozdog, H.; Brancus, I.M.; Buchholz, P.; Cantoni, E.; Chiavassa, A.; Cossavella, F.

    2012-01-01

    The KASCADE–Grande experiment, located at Karlsruhe Institute of Technology (Germany) is a multi-component extensive air-shower experiment devoted to the study of cosmic rays and their interactions at primary energies 10 14 –10 18 eV. Main goals of the experiment are the measurement of the all-particle energy spectrum and mass composition in the 10 16 –10 18 eV range by sampling charged (N ch ) and muon (N μ ) components of the air shower. The method to derive the energy spectrum and its uncertainties, as well as the implications of the obtained result, is discussed. An overview of the analyses performed by KASCADE–Grande to derive the mass composition of the measured high-energy comic rays is presented as well.

  11. Results from KASCADE-Grande

    Bertaina, M., E-mail: bertaina@to.infn.it [Dipartimento di Fisica Generale dell' Universita, Torino (Italy); Apel, W.D. [Institut fuer Kernphysik, KIT - Karlsruher Institut fuer Technologie (Germany); Arteaga-Velazquez, J.C. [Universidad Michoacana, Instituto de Fisica y Matematicas, Morelia (Mexico); Bekk, K. [Institut fuer Kernphysik, KIT - Karlsruher Institut fuer Technologie (Germany); Bluemer, J. [Institut fuer Kernphysik, KIT - Karlsruher Institut fuer Technologie (Germany); Institut fuer Experimentelle Kernphysik, KIT - Karlsruher Institut fuer Technologie (Germany); Bozdog, H. [Institut fuer Kernphysik, KIT - Karlsruher Institut fuer Technologie (Germany); Brancus, I.M. [National Institute of Physics and Nuclear Engineering, Bucharest (Romania); Buchholz, P. [Fachbereich Physik, Universitaet Siegen (Germany); Cantoni, E. [Dipartimento di Fisica Generale dell' Universita, Torino (Italy); Istituto di Fisica dello Spazio Interplanetario, INAF Torino (Italy); Chiavassa, A. [Dipartimento di Fisica Generale dell' Universita, Torino (Italy); Cossavella, F. [Institut fuer Experimentelle Kernphysik, KIT - Karlsruher Institut fuer Technologie (Germany); and others

    2012-11-11

    The KASCADE-Grande experiment, located at Karlsruhe Institute of Technology (Germany) is a multi-component extensive air-shower experiment devoted to the study of cosmic rays and their interactions at primary energies 10{sup 14}-10{sup 18} eV. Main goals of the experiment are the measurement of the all-particle energy spectrum and mass composition in the 10{sup 16}-10{sup 18} eV range by sampling charged (N{sub ch}) and muon (N{sub {mu}}) components of the air shower. The method to derive the energy spectrum and its uncertainties, as well as the implications of the obtained result, is discussed. An overview of the analyses performed by KASCADE-Grande to derive the mass composition of the measured high-energy comic rays is presented as well.

  12. Spectrometers for compact neutron sources

    Voigt, J.; Böhm, S.; Dabruck, J. P.; Rücker, U.; Gutberlet, T.; Brückel, T.

    2018-03-01

    We discuss the potential for neutron spectrometers at novel accelerator driven compact neutron sources. Such a High Brilliance Source (HBS) relies on low energy nuclear reactions, which enable cryogenic moderators in very close proximity to the target and neutron optics at comparably short distances from the moderator compared to existing sources. While the first effect aims at increasing the phase space density of a moderator, the second allows the extraction of a large phase space volume, which is typically requested for spectrometer applications. We find that competitive spectrometers can be realized if (a) the neutron production rate can be synchronized with the experiment repetition rate and (b) the emission characteristics of the moderator can be matched to the phase space requirements of the experiment. MCNP simulations for protons or deuterons on a Beryllium target with a suitable target/moderator design yield a source brightness, from which we calculate the sample fluxes by phase space considerations for different types of spectrometers. These match closely the figures of todays spectrometers at medium flux sources. Hence we conclude that compact neutron sources might be a viable option for next generation neutron sources.

  13. Grandes números primos

    Bang, Thöger

    2012-01-01

    En las escuelas danesas la teoría de los números se ha ido restringiendo gradualmente hasta no incluir sino la demostración de la descomposición univoca de los números enteros en números primos y la demostración del teorema clásico de EUCLIDES sobre la existencia de un número primo arbitrariamente grande.

  14. Grand unification theory and technicolor

    Rubakov, V.A.; Shaposhnikov, M.E.

    1983-01-01

    The lecture course can be considered as introduction to the problems concerning grand unification models. The course is incomplete. Such problems as CP-violations in strong interactions and the problem of gravitational interaction inclusion in the scheme of grand unification theory are not touched upon. Models of early unification, in which strong, weak and electromagnetic interactions are compared according to the ''strength'' at energies of about 10 5 -10 6 GeV, are not discussed. Models with horizontal symmetry, considering different generations of quarks and leptons from one viewpoint, are not analyzed. Cosmological applications of supersymmetric unified theories are not considered. Certain problems of standard elementary particle theory, philosophy of the great unification, general properties of the grand unification models and the main principles of the construction of models: the SU(5) model, models on the SO(10) groups, have been considered. The problem of supersymmetric unification hierarchies, supersymmetric generalization of the minimum SU(5) model, supersymmetry violation and the problem of hierarchies, phenomenology of the o.rand unification models, cosmological application and technicolour, are discussed

  15. Mini ion trap mass spectrometer

    Dietrich, D.D.; Keville, R.F.

    1995-09-19

    An ion trap is described which operates in the regime between research ion traps which can detect ions with a mass resolution of better than 1:10{sup 9} and commercial mass spectrometers requiring 10{sup 4} ions with resolutions of a few hundred. The power consumption is kept to a minimum by the use of permanent magnets and a novel electron gun design. By Fourier analyzing the ion cyclotron resonance signals induced in the trap electrodes, a complete mass spectra in a single combined structure can be detected. An attribute of the ion trap mass spectrometer is that overall system size is drastically reduced due to combining a unique electron source and mass analyzer/detector in a single device. This enables portable low power mass spectrometers for the detection of environmental pollutants or illicit substances, as well as sensors for on board diagnostics to monitor engine performance or for active feedback in any process involving exhausting waste products. 10 figs.

  16. Evaluation of the ROTAX spectrometer

    Tietze-Jaensch, H.; Schmidt, W.; Geick, R.

    1997-01-01

    After installation of the new-type rotating crystal analyser spectrometer ROTAX at ISIS, we report on practical experience and describe its current status. The rotating analyser technique works feasibly and reliably and provides an ultimate scan flexibility on a pulsed time-of-flight neutron spectrometer. The spinning analyser achieves a mulitplex advantage factor of ca. 50 without compromising the resolution of the instrument. Despite these instrument merits its individual beam position at ISIS has only an unsatisfactorily weak flux, thus hindering this instrument yet to become fully competitive with other high-performance neutron spectrometers based at high-flux reactors. However, we strongly recommend a ROTAX-type instrument to be emphasized when the instrumentation suite of the future European spallation source ESS will come under scrutiny. (orig.)

  17. Forward spectrometers at the SSC

    Bjorken, J.D.

    1986-01-01

    Most of SSC phase space and a great deal of physics potential is in the forward/backward region (absolute value of theta < 100 mrad). Comprehensive open-geometry spectrometers are feasible and very cost effective. Examples of such devices are sketched. Because such spectrometers are very long and may operate at high β and longer bunch spacing, they impact now on SSC interaction - region design. The data acquisition load is as heavy as for central detectors, although there may be less emphasis on speed and more emphasis on sophisticated parallel and/or distributed processing for event selection, as well as on high-capacity buffering

  18. Interfacing an aspiration ion mobility spectrometer to a triple quadrupole mass spectrometer

    Adamov, Alexey; Viidanoja, Jyrki; Kaerpaenoja, Esko; Paakkanen, Heikki; Ketola, Raimo A.; Kostiainen, Risto; Sysoev, Alexey; Kotiaho, Tapio

    2007-01-01

    This article presents the combination of an aspiration-type ion mobility spectrometer with a mass spectrometer. The interface between the aspiration ion mobility spectrometer and the mass spectrometer was designed to allow for quick mounting of the aspiration ion mobility spectrometer onto a Sciex API-300 triple quadrupole mass spectrometer. The developed instrumentation is used for gathering fundamental information on aspiration ion mobility spectrometry. Performance of the instrument is demonstrated using 2,6-di-tert-butyl pyridine and dimethyl methylphosphonate

  19. Small angle single arm spectrometer

    Chien, C.Y.

    1976-01-01

    A study is given of an experiment described in the 1975 Summer Study to review the adequacy of the apparatus for its physics goals, equipment needs, logistic needs, vacuum chambers, compatibility with other experiments and to summarize its impacts on ISABELLE. The spectrometer is designed to study single particle inclusive spectra near x = 1 with particle identification and good momentum resolution

  20. Charged particle scintillation mass spectrometer

    Baranov, P.S.; Zhuravlev, E.E.; Nafikov, A.A.; Osadchi , A.I.; Raevskij, V.G.; Smirnov, P.A.; Cherepnya, S.N.; Yanulis, Yu.P.

    1982-01-01

    A scintillation mass-spectrometer for charged particle identification by the measured values of time-of-flight and energy operating on line with the D-116 computer is described. Original time detectors with 100x100x2 mm 3 and 200x2 mm 2 scintillators located on the 1- or 2 m path length are used in the spectrometer. The 200x200x200 mm 3 scintillation unit is used as a E-counter. Time-of-flight spectra of the detected particles on the 2 m path length obtained in spectrometer test in the beam of charged particles escaping from the carbon target at the angle of 130 deg under 1.2 GeV bremsstrahlung beam of the ''Pakhra'' PIAS synchrotron are presented. Proton and deuteron energy spectra as well as mass spectrum of all the particles detected by the spectrometer are given. Mass resolution obtained on the 2 m path length for π-mesons is +-25%, for protons is +-5%, for deuterons is +-3%

  1. IPNS-I chopper spectrometers

    Price, D.L.; Carpenter, J.M.; Pelizzari, C.A.; Sinha, S.K.; Bresof, I.; Ostrowski, G.E.

    1982-01-01

    We briefly describe the layout and operation of the two chopper experiments at IPNS-I. The recent measurement on solid 4 He by Hilleke et al. provides examples of time-of-flight data from the Low Resolution Chopper Spectrometer

  2. The story of a spectrometer

    Butcher, P.; Uhrberg, R.

    1995-01-01

    This article describes the development and design of a photoelectron spectrometer for use by researchers using synchrotron radiation. Originally developed for a new beam line at the MAXI Synchrotron at Lund in Sweden, the device has many research applications where its high level of performance is required. (UK)

  3. Mid infrared MEMS FTIR spectrometer

    Erfan, Mazen; Sabry, Yasser M.; Mortada, Bassem; Sharaf, Khaled; Khalil, Diaa

    2016-03-01

    In this work we report, for the first time to the best of our knowledge, a bulk-micromachined wideband MEMS-based spectrometer covering both the NIR and the MIR ranges and working from 1200 nm to 4800 nm. The core engine of the spectrometer is a scanning Michelson interferometer micro-fabricated using deep reactive ion etching (DRIE) technology. The spectrum is obtained using the Fourier Transform techniques that allows covering a very wide spectral range limited by the detector responsivity. The moving mirror of the interferometer is driven by a relatively large stroke electrostatic comb-drive actuator. Zirconium fluoride (ZrF4) multimode optical fibers are used to connect light between the white light source and the interferometer input, as well as the interferometer output to a PbSe photoconductive detector. The recorded signal-to-noise ratio is 25 dB at the wavelength of 3350 nm. The spectrometer is successfully used in measuring the absorption spectra of methylene chloride, quartz glass and polystyrene film. The presented solution provides a low cost method for producing miniaturized spectrometers in the near-/mid-infrared.

  4. Inside the ETH spectrometer magnet

    1974-01-01

    The ETH spectrometer magnet being prepared for experiment S134, which uses a frozen spin polarized target to study the associated production of a kaon and a lambda by negative pions interacting with protons (CERN-ETH, Zurich-Helsinki-Imperial College, London-Southampton Collaboration). (See Photo Archive 7406316)

  5. Grand unification: quo vadis domine

    Senjanovic, G.

    1985-01-01

    The present theoretical and experimental situation with grand unification is summarized. The issues of proton decay and the Weinberg angle are addressed, going through the predictions of both the standard SU(5) theory and its supersymmetric extension. The SO(10) theory, which provides a minimal one family model, is then studied. The gravitational characteristics of domain walls and strings are then discussed. It is argued that there is a need to go beyond SO(10) in order to incorporate a unified picture of families. This leads to the prediction of mirror fermions, whose physics is analyzed. 31 refs

  6. Graafikatriennaali grand prix Korea kunstnikule

    1998-01-01

    Tallinna XI graafikatriennaali rahvusvaheline žürii andis grand prix korea kunstnikule Chung¡Sang-Gonile, kolm võrdset preemiat - soome kunstnikele Anita Jensenile ja Tapani Mikkonenile ning jaapani kunstnikule Estuko Obatale. Eesti Kunstimuuseumi preemia - Wendy Swallow. Tallinna linna preemia ja Ivar Luki sponsoripreemia - Walter Jule. Sponsoripreemiad : Paletti Eesti AS preemia - Inga Heamägi; Rannila Profiili preemia - Mojca Zlokarnik; UNDP preemia - Andrea Juan. Rotermanni soolalao arhitektuuri- ja kunstikeskuse diplom - Lis Ingram, Heli Päivikki Kurunsaari, Randi Strand, Wendy Swallow

  7. Grand Challenges of Enterprise Integration

    Brosey, W.D; Neal, R.E.; Marks, D.

    2001-04-01

    Enterprise Integration connects and combines people, processes, systems, and technologies to ensure that the right people and the right processes have the right information and the right resources at the right time. A consensus roadmap for Technologies for Enterprise Integration was created as part of an industry/government/academia partnership in the Integrated Manufacturing Technology Initiative (IMTI). Two of the grand challenges identified by the roadmapping effort will be addressed here--Customer Responsive Enterprises and Totally Connected Enterprises. Each of these challenges is briefly discussed as to the current state of industry and the future vision as developed in the roadmap.

  8. Grand Challenges for Environmental Magnetism

    Verosub, K. L.

    2009-05-01

    The development of new, inexpensive, and rapid geochemical methods for determining the ages of geologic materials, their elemental composition, and their isotopic ratios over a broad array of elements puts into sharp focus the question: What information can environmental magnetic methods provide that can't be obtained using these other methods? Because iron is ubiquitous in the Earth's crust and because it exists in so many different forms, a discipline that looks in detail at iron-bearing minerals does have the potential to make significant contributions to the study of surficial processes. However, to reach that potential requires the development of new environmental magnetic methods. I would like to put forward three Grand Challenges for environmental magnetism that have the potential to move the field forward to a new level of scientific sophistication and that will allow environmental magnetists to compete successfully in a world increasingly dominated by geochemists. The first Grand Challenge is the development of new techniques that lead to the direct and unambiguous identification of the full suite of magnetic minerals. For many environmental magnetic applications, the key magnetic minerals are not just magnetite and hematite but also iron oxy-hydroxides (goethite, lepidocrocite, akaganeite, ferrihydrite), carbonates (siderite) and sulfides (pyrrhotite and greigite) as well as compounds involving iron and other transition metals (cobalt and nickel). The second Grand Challenge is the development of new analytical methods that provide specific quantitative values for the amount of each magnetic mineral present in a sample. One promising approach to this problem is the application of two- or three-component multivariate analysis to arrays of downcore environmental magnetic parameters. The third Grand Challenge is the development of new ways of determining, not just the average values, but the actual distributions of grain sizes and coercivities of each mineral

  9. The Grand Challenges of Nanotechnology

    Lane, Neal

    2001-01-01

    Amazing breakthroughs and advances continue to be made in nanoscale science and engineering and the rapidly emerging field of nanotechnology, including near-commercial applications in biomedicine, computing and environmental protection. The National Nanotechnology Initiative, begun by the Clinton Administration has placed nanoscale research on a new funding trajectory. But, many 'grand challenges' must be overcome, technical ones as well as those related to funding, science and technology workforce, and the need for stronger collaboration across discipline, organizations, government agencies and with other countries

  10. Compact Spectrometers Based on Linear Variable Filters

    National Aeronautics and Space Administration — Demonstrate a linear-variable spectrometer with an H2RG array. Linear Variable Filter (LVF) spectrometers provide attractive resource benefits – high optical...

  11. Scintillation forward spectrometer of the SPHERE setup

    Anisimov, Yu.S.; Afanas'ev, S.V.; Bondarev, V.K.

    1991-01-01

    The construction of the forward spectrometer for the 4π SPHERE setup to study multiple production of particles in nucleus-nucleus interactions is described. The measured parameters of the spectrometer detectors are presented. 7 refs.; 14 figs.; 1 tab

  12. Combined raman spectrometer/laser-induced breakdown spectrometer design concept

    Bazalgette Courrèges-Lacoste, Gregory; Ahlers, Berit; Boslooper, Erik; Rull-Perez, Fernando; Maurice, Sylvestre

    2017-11-01

    Amongst the different instruments that have been preselected to be on-board the Pasteur payload on ExoMars is the Raman/ Laser Induced Breakdown Spectroscopy (LIBS) instrument. Raman spectroscopy and LIBS will be integrated into a single instrument sharing many hardware commonalities. An international team under the lead of TNO has been gathered to produce a design concept for a combined Raman Spectrometer/ LIBS Elegant Bread-Board (EBB). The instrument is based on a specifically designed extremely compact spectrometer with high resolution over a large wavelength range, suitable for both Raman spectroscopy and LIBS measurements. Low mass, size and resources are the main drivers of the instrument's design concept. The proposed design concept, realization and testing programme for the combined Raman/ LIBS EBB is presented as well as background information on Raman and LIBS.

  13. Electron spectrometer for gas-phase spectroscopy

    Bozek, J.D.; Schlachter, A.S. [Ernest Orlando Lawrence Berkeley National Lab., CA (United States)

    1997-04-01

    An electron spectrometer for high-resolution spectroscopy of gaseous samples using synchrotron radiation has been designed and constructed. The spectrometer consists of a gas cell, cylindrical electrostatic lens, spherical-sector electron energy analyzer, position-sensitive detector and associated power supplies, electronics and vacuum pumps. Details of the spectrometer design are presented together with some representative spectra.

  14. Acquisition of HPLC-Mass Spectrometer

    2015-08-18

    31-Jan-2015 Approved for Public Release; Distribution Unlimited Final Report: Acquisition of HPLC -Mass Spectrometer The views, opinions and/or findings...published in peer-reviewed journals: Final Report: Acquisition of HPLC -Mass Spectrometer Report Title The acquisition of the mass spectrometer has been a

  15. Lessons learned with the SAGE spectrometer

    Sorri, J; Greenlees, P T; Jones, P; Julin, R; Konki, J; Pakarinen, J; Rahkila, P; Sandzelius, M; Uusitalo, J; Papadakis, P; Cox, D M; Herzberg, R D

    2012-01-01

    The SAGE spectrometer combines a high-efficiency γ-ray detection system with an electron spectrometer. Some of the design features have been known to be problematic and surprises have come up during the early implementation of the spectrometer. Tests related to bismuth germanate Compton-suppression shields, electron detection efficiency and an improved cooling system are discussed in the paper. (paper)

  16. Airborne gamma ray spectrometer surveying

    1991-01-01

    The International Atomic Energy Agency (IAEA) in its role as collector and disseminator of information on nuclear techniques has long had an interest in gamma ray spectrometer methods and has published a number of Technical Reports on various aspects of the subject. At an Advisory Group Meeting held in Vienna in November 1986 to review appropriate activities the IAEA could take following the Chernobyl accident, it was recommended that preparation begin on a new Technical Report on airborne gamma ray spectrometer surveying, taking into account the use of the technique for environmental monitoring as well as for nuclear emergency response requirements. Shortly thereafter the IAEA became the lead organization in the Radioelement Geochemical Mapping section of the International Geological Correlation Programme/United Nations Educational, Scientific and Cultural Organization (UNESCO) Project on International Geochemical Mapping. These two factors led to the preparation of the present Technical Report. 18 figs, 4 tabs

  17. Development of cold neutron spectrometers

    Lee, Changhee; Lee, C. H.; So, J. Y.; Park, S.; Han, Y. S.; Cho, S. J.; Moon, M. K.; Choi, Y. H.; Sun, G. M.

    2012-03-01

    □ Cold Neutron Triple Axsis Spectrometer (Cold-TAS) Development Ο Fabrication and Installation of the Major Cold-TAS Components Ο Performance Test of the Cold-TAS □ Cold Neutron Time-of-Flight Spectrometer(DC-TOF) Development Ο Fabrication of the Major DC-TOF Components Ο Development DC-TOF Data Reduction Software □ Expected Contribution The two world-class inelastic neutron scattering instruments measure atomic or molecular scale dynamics of meV energy range. This unprecedented measurement capability in the country will enable domestic and international scientists to observe new phenomena in their materials research to obtain world class results. Especially those who work in the fields of magnetic properties of superconductors and multiferroics, molecular dynamics, etc. will get more benefit from these two instruments

  18. Exploiting a Transmission Grating Spectrometer

    Ronald E. Bell

    2004-12-08

    The availability of compact transmission grating spectrometers now allows an attractive and economical alternative to the more familiar Czerny-Turner configuration for many high-temperature plasma applications. Higher throughput is obtained with short focal length refractive optics and stigmatic imaging. Many more spectra can be obtained with a single spectrometer since smaller, more densely packed optical input fibers can be used. Multiple input slits, along with a bandpass filter, can be used to maximize the number of spectra per detector, providing further economy. Curved slits can correct for the strong image curvature of the short focal length optics. Presented here are the governing grating equations for both standard and high-dispersion transmission gratings, defining dispersion, image curvature, and desired slit curvature, that can be used in the design of improved plasma diagnostics.

  19. Exploiting a Transmission Grating Spectrometer

    Bell, Ronald E.

    2004-01-01

    The availability of compact transmission grating spectrometers now allows an attractive and economical alternative to the more familiar Czerny-Turner configuration for many high-temperature plasma applications. Higher throughput is obtained with short focal length refractive optics and stigmatic imaging. Many more spectra can be obtained with a single spectrometer since smaller, more densely packed optical input fibers can be used. Multiple input slits, along with a bandpass filter, can be used to maximize the number of spectra per detector, providing further economy. Curved slits can correct for the strong image curvature of the short focal length optics. Presented here are the governing grating equations for both standard and high-dispersion transmission gratings, defining dispersion, image curvature, and desired slit curvature, that can be used in the design of improved plasma diagnostics

  20. QQDDQ magnet spectrometer 'BIG KARL'

    Martin, S A; Hardt, A; Meissburger, J; Berg, G P.A.; Hacker, U; Huerlimann, W; Roemer, J G.M.; Sagefka, T; Retz, A; Schult, O W.B.

    1983-09-01

    A magnet spectrometer consisting of two quadrupoles, two dipole magnets and another larger quadrupole in front of the detector was designed and installed at the nuclear research institute of the KFA Juelich. It has been used for charged-particle spectroscopy at the isochronous cyclotron since early 1979. Special features of the spectrometer are variable and high dispersion, coils for higher order field corrections in the dipole magnets and a focal plane perpendicular to the optical axis. A large mass-energy product of mE/q/sup 2/ < 540 u x MeV, an angular acceptance of d..cap omega..<12.5 msr, a high resolving power of p/..delta..p up to 3 x 10/sup 4/ and the possibility of kinematical corrections up to K=0.8 make the instrument a very versatile tool for many experiments in the fields of nuclear and atomic physics. 51 references.

  1. Heavy-ion-spectrometer system

    1982-05-01

    LBL safety policy (Pub 300 Appendix E) states that every research operation with a Class A risk potential (DOE 5484.1) should identify potentially hazardous procedures associated with the operation and develop methods for accomplishing the operation safely without personnel injury or property damage. The rules and practices that management deems to be minimally necessary for the safe operations of the Heavy Ion Spectrometer System (HISS) in the Bevatron Experimental Hall (51B) are set forth in this Operation Safety Procedures

  2. The HISS spectrometer at LBL

    Greiner, D.

    1981-01-01

    The Heavy Ion Spectrometer System at LBL is designed to be a general purpose experimental work bench able to support a wide variety of experiments. Our philosophy is to provide instruments capable of investigating, with multi-particle sensitivity, a large portion of phase space. We have not chosen a particular region such as mid-rapidity or projectile frame, but instead, have made sure that the magnet and the instrumentation allow these choices as well as many others. (orig.)

  3. Heavy-ion-spectrometer system

    1982-05-01

    LBL safety policy (Pub 300 Appendix E) states that every research operation with a Class A risk potential (DOE 5484.1) should identify potentially hazardous procedures associated with the operation and develop methods for accomplishing the operation safely without personnel injury or property damage. The rules and practices that management deems to be minimally necessary for the safe operations of the Heavy Ion Spectrometer System (HISS) in the Bevatron Experimental Hall (51B) are set forth in this Operation Safety Procedures (OSP).

  4. A spectrometer for submicron particles

    Pourprix, M.

    1995-01-01

    The electrostatic spectrometer for aerosol particles, is composed of two coaxial parallel conductive disks between which an electric field is established; an annular slot in the first disk allows for the atmosphere air intake. Suction and injection systems, and a third intermediate conductive disk are used to carry out a dynamic confinement that allows for the separation of particles having various electronic mobility and the determination of the suspended particle size distribution. Application to aerosol size spectrum determination and air quality monitoring

  5. The fast slow TDPAC spectrometer

    Cekic, B.; Koicki, S.; Manasijevic, M.; Ivanovic, N.; Koteski, V.; Milosevic, Z.; Radisavljevic, I.; Cavor, J.; Novakovic, N.; Marjanovic, D.

    2001-01-01

    A 2-BaF 2 detector - fast slow time spectrometer for time differential perturbed angular correlations (TDPAC) experiments is described. This apparatus has been developed in the Group for Hyperfine Interactions in the Institute for Nuclear Sciences in VINCA. The excellent time resolution combined with high efficiency offered by these detectors enables one high counting rate performance and is operating in the wide temperature range 78-1200 K. (author)

  6. Medium energy charged particle spectrometer

    Keppler, E.; Wilken, B.; Richer, K.; Umlauft, G.; Fischer, K.; Winterhoff, H.P.

    1976-10-01

    The charged particle spectrometer E8 on HELIOS A and B will be described in some detail. It covers proton energies from 80 keV to 6 MeV, electrons from 20 keV to 2 MeV, and positrons from 150 to 550 keV. Its flight performance will be discussed. From examples of measurements the capability of the instrument will be demonstrated. (orig.) [de

  7. The RISC-spectrometer experiment

    Pinter, Gy.

    1981-01-01

    The RISC (Relativistic Ionising Streamer Chamber) spectrometer (situated at Protvino, joining the accelerator) is discussed, and the experiment carried out in international cooperation is presented. The beam monitor, the trigger system and the control and data recording system as well as the streamer spark chamber are detailed (the latter is the largest of our time). Examples of the main experiments as well as the work carried out in Budapest are discussed briefly. (Sz.J.)

  8. Google Earth Grand Tour Themes

    De Paor, D. G.; Whitmeyer, S. J.; Bentley, C.; Dordevic, M. M.

    2014-12-01

    As part of an NSF TUES Type 3 project entitled "Google Earth for Onsite and Distance Education (GEODE)," we are assembling a "Grand Tour" of locations on Earth and other terrestrial bodies that every geoscience student should know about and visit at least in virtual reality. Based on feedback from colleagues at previous meetings, we have identified nine Grand Tour themes: "Plates and Plumes," "Rocks and Regions," "Geology Through Time," "The Mapping Challenge*," "U.S. National Parks*," "The Magical Mystery Tour*," "Resources and Hazards," "Planets and Moons," and "Top of the Pops." Themes marked with an asterisk are most developed at this stage and will be demonstrated in real time. The Mapping Challenge invites students to trace geological contacts, measure bedding strike and dip and the plunge, trend, and facing of a fold. There is an advanced tool for modeling periclinal folds. The challenge is presented in a game-like format with an emphasis on puzzle-solving that will appeal to students regardless of gender. For the tour of U.S. national parks, we divided the most geologically important parks into four groups—Western Pacific, West Coast, Rockies, and East Coast. We are combining our own team's GigaPan imagery with imagery already available on the Internet. There is a great deal of imagery just waiting to be annotated for geological education purposes. The Magical Mystery Tour takes students to Google Streetview locations selected by instructors. Students are presented with questions or tasks and are given automatic feedback. Other themes are under development. Within each theme, we are crowd-sourcing contributions from colleagues and inviting colleagues to vote for or against proposed locations and student interactions. The GEODE team includes the authors and: Heather Almquist, Stephen Burgin, Cinzia Cervato, Gene Cooper, Paul Karabinos, Terry Pavlis, Jen Piatek, Bill Richards, Jeff Ryan, Ron Schott, Kristen St. John, and Barb Tewksbury.

  9. Next Generation Innovation Policy and Grand Challenges

    Kuhlmann, Stefan; Rip, Arie

    2018-01-01

    The paper explores transformative ways to address Grand Challenges, while locating them in a broader diagnosis of ongoing changes. Coping with Grand Challenges is a challenge in its own right, for policy as well as for science, technology, and innovation actors. The paper presents building blocks

  10. Proton hexality in local grand unification

    Foerste, Stefan; Nilles, Hans Peter [Bonn Univ. (Germany). Bethe Center for Theoretical Physics and Physikalisches Institut; Ramos-Sanchez, Saul [Deutsches Elektronen-Synchrotron (DESY), Hamburg (Germany); Vaudrevange, Patrick K.S. [Muenchen Univ. (Germany). Arnold Sommerfeld Center for Theoretical Physics

    2010-07-15

    Proton hexality is a discrete symmetry that avoids the problem of too fast proton decay in the supersymmetric extension of the standard model. Unfortunately it is inconsistent with conventional grand unification. We show that proton hexality can be incorporated in the scheme of ''Local Grand Unification'' discussed in the framework of model building in (heterotic) string theory. (orig.)

  11. An ultralow background germanium gamma-ray spectrometer

    Reeves, R.H.; Brodzinski, R.L.; Hensley, W.K.; Ryge, P.

    1984-01-01

    The monitoring of minimum detectable activity is becoming increasingly important as environmental concerns and regulations require more sensitive measurement of the radioactivity levels in the workplace and the home. In measuring this activity, however, the background becomes one of the limiting factors. Anticoincidence systems utilizing both NaI(T1) and plastic scintillators have proven effective in reducing some components of the background, but radiocontaminants in the various regions of these systems have limited their effectiveness, and their cost is often prohibitive. In order to obtain a genuinely low background detector system, all components must be free of detectable radioactivity, and the cosmic ray produced contribution must be significantly reduced. Current efforts by the authors to measure the double beta decay of Germanium 76 as predicted by Grand Unified Theories have resulted in the development of a high resolution germanium diode gamma spectrometer with an exceptionally low background. This paper describes the development of this system, outlines the configuration and operation of its preamplifier, linear amplifier, analog-to-digital converter, 4096-channel analyzer, shielding consisting of lead-sandwiched plastic scintillators wrapped in cadmium foil, photomultiplier, and its pulse generator and discriminator, and then discusses how the system can be utilized to significantly reduce the background in high resolution photon spectrometers at only moderate cost

  12. Ion mobility spectrometer / mass spectrometer (IMS-MS).

    Hunka Deborah Elaine; Austin, Daniel E.

    2005-07-01

    The use of Ion Mobility Spectrometry (IMS) in the Detection of Contraband Sandia researchers use ion mobility spectrometers for trace chemical detection and analysis in a variety of projects and applications. Products developed in recent years based on IMS-technology include explosives detection personnel portals, the Material Area Access (MAA) checkpoint of the future, an explosives detection vehicle portal, hand-held detection systems such as the Hound and Hound II (all 6400), micro-IMS sensors (1700), ordnance detection (2500), and Fourier Transform IMS technology (8700). The emphasis to date has been on explosives detection, but the detection of chemical agents has also been pursued (8100 and 6400). Combining Ion Mobility Spectrometry (IMS) with Mass Spectrometry (MS) is described. The IMS-MS combination overcomes several limitations present in simple IMS systems. Ion mobility alone is insufficient to identify an unknown chemical agent. Collision cross section, upon which mobility is based, is not sufficiently unique or predictable a priori to be able to make a confident peak assignment unless the compounds present are already identified. Molecular mass, on the other hand, is much more readily interpreted and related to compounds. For a given compound, the molecular mass can be determined using a pocket calculator (or in one's head) while a reasonable value of the cross-section might require hours of computation time. Thus a mass spectrum provides chemical specificity and identity not accessible in the mobility spectrum alone. In addition, several advanced mass spectrometric methods, such as tandem MS, have been extensively developed for the purpose of molecular identification. With an appropriate mass spectrometer connected to an ion mobility spectrometer, these advanced identification methods become available, providing greater characterization capability.

  13. Ion Mobility Spectrometer / Mass Spectrometer (IMS-MS)

    Hunka, Deborah E. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Austin, Daniel [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)

    2005-10-01

    The use of Ion Mobility Spectrometry (IMS)in the Detection of Contraband Sandia researchers use ion mobility spectrometers for trace chemical detection and analysis in a variety of projects and applications. Products developed in recent years based on IMS-technology include explosives detection personnel portals, the Material Area Access (MAA) checkpoint of the future, an explosives detection vehicle portal, hand-held detection systems such as the Hound and Hound II (all 6400), micro-IMS sensors (1700), ordnance detection (2500), and Fourier Transform IMS technology (8700). The emphasis to date has been on explosives detection, but the detection of chemical agents has also been pursued (8100 and 6400).

  14. La Grande: volver a empezar

    Julio Premat

    2011-07-01

    Full Text Available Este texto, borrador de un trabajo más amplio, pretende despejar algunas pistas de lectura de La grande, en tanto que paradójico final de la producción de Saer. Digo “paradójico” porque puede tomársela como una novela de comienzo o de origen : de un volver a empezar, en todos los sentidos del término. En esa perspectiva podrían estudiarse algunos núcleos temáticos (como el retorno o el recuerdo de cara a la construcción del texto, a la relación planteada con la tradición y a la singular historia de su escritura (y al material genético que rodea y completa esta novela a la vez inacabada y póstuma. En esta intervención, la idea es la de comentar tres textos, escenas o frases del texto, y a partir de allí esbozar pistas para un estudio que está en ciernes.Première ébauche d’un travail de plus d’ampleur, ce texte vise à éclairer quelques pistes de lecture de La grande, en tant que fin paradoxale de la production de Saer. Je dis « paradoxale » parce que l’on peut considérer cette œuvre comme un roman des commencements ou des origines : comme un retour aux débuts, dans tous les sens du terme. Dans cette perspective, plusieurs nœuds thématiques (comme le retour ou le souvenir pourraient être étudiés en relation à la construction du texte, à la relation qui s’établit avec la tradition et à la singulière histoire de son écriture (et au matériau génétique qui entoure et complète ce roman, à la fois inachevé et posthume. Il sera question ici de commenter trois textes, scènes ou phrases du texte, et d’ébaucher à partir de là quelques pistes pour une étude à l’état naissant.The objective of this text, a draft for a broader work, is to outline some reading clues for La grande, inasmuch as it constitutes a paradoxical ending of Saer’s production. I say “paradoxical” because we can consider this work a novel of beginnings or of origins: a return to the beginning, in every meaning of the

  15. New spectrometer for charged particles

    Wajsfelner, Rene

    1970-02-01

    This thesis is devoted to the study and development of an electrostatic spectrometer which is not only more accurate for the determination of size distributions of electrically charged radio-active atmospheric aerosols, but which can also be used for measuring the grain-size distribution of any cloud of particles which will previously have been charged according to a known, reproducible law. An experimental study has been made of the development of this precipitator and also of its calibration. The electrical charge on spherical polystyrene latex particles suspended in air by atomization has been studied; a theoretical explanation of these results is put forward. (author) [fr

  16. Ion Mobility Spectrometer Field Test

    Smith, Nicholas [Argonne National Lab. (ANL), Argonne, IL (United States). Nuclear Engineering Division; McLain, Derek [Argonne National Lab. (ANL), Argonne, IL (United States). Nuclear Engineering Division; Steeb, Jennifer [Argonne National Lab. (ANL), Argonne, IL (United States). Nuclear Engineering Division

    2017-12-20

    The Morpho Saffran Itemizer 4DX Ion Mobility Spectrometer previously used to detect uranium signatures in FY16 was used at the former New Brunswick Facility, a past uranium facility located on site at Argonne National Laboratory. This facility was chosen in an attempt to detect safeguards relevant signatures and has a history of processing uranium at various enrichments, chemical forms, and purities; various chemicals such as nitric acid, uranium fluorides, phosphates and metals are present at various levels. Several laboratories were sampled for signatures of nuclear activities around the laboratory. All of the surfaces that were surveyed were below background levels of the radioanalytical instrumentation and determined to be radiologically clean.

  17. The Alpha Magnetic Spectrometer (AMS)

    Alcaraz, J.; Alpat, B.; Ambrosi, G.; Anderhub, H.; Ao, L.; Arefiev, A.; Azzarello, P.; Babucci, E.; Baldini, L.; Basile, M.; Barancourt, D.; Barao, F.; Barbier, G.; Barreira, G.; Battiston, R.; Becker, R.; Becker, U.; Bellagamba, L.; Bene, P.; Berdugo, J.; Berges, P.; Bertucci, B.; Biland, A.; Bizzaglia, S.; Blasko, S.; Boella, G.; Boschini, M.; Bourquin, M.; Brocco, L.; Bruni, G.; Buenerd, M.; Burger, J.D.; Burger, W.J.; Cai, X.D.; Camps, C.; Cannarsa, P.; Capell, M.; Casadei, D.; Casaus, J.; Castellini, G.; Cecchi, C.; Chang, Y.H.; Chen, H.F.; Chen, H.S.; Chen, Z.G.; Chernoplekov, N.A.; Chiueh, T.H.; Chuang, Y.L.; Cindolo, F.; Commichau, V.; Contin, A.; Crespo, P.; Cristinziani, M.; Cunha, J.P. da; Dai, T.S.; Deus, J.D.; Dinu, N.; Djambazov, L.; DAntone, I.; Dong, Z.R.; Emonet, P.; Engelberg, J.; Eppling, F.J.; Eronen, T.; Esposito, G.; Extermann, P.; Favier, J.; Fiandrini, E.; Fisher, P.H.; Fluegge, G.; Fouque, N.; Galaktionov, Yu.; Gervasi, M.; Giusti, P.; Grandi, D.; Grimm, O.; Gu, W.Q.; Hangarter, K.; Hasan, A.; Hermel, V.; Hofer, H.; Huang, M.A.; Hungerford, W.; Ionica, M.; Ionica, R.; Jongmanns, M.; Karlamaa, K.; Karpinski, W.; Kenney, G.; Kenny, J.; Kim, W.; Klimentov, A.; Kossakowski, R.; Koutsenko, V.; Kraeber, M.; Laborie, G.; Laitinen, T.; Lamanna, G.; Laurenti, G.; Lebedev, A.; Lee, S.C.; Levi, G.; Levtchenko, P.; Liu, C.L.; Liu, H.T.; Lopes, I.; Lu, G.; Lu, Y.S.; Luebelsmeyer, K.; Luckey, D.; Lustermann, W.; Mana, C.; Margotti, A.; Mayet, F.; McNeil, R.R.; Meillon, B.; Menichelli, M.; Mihul, A.; Mourao, A.; Mujunen, A.; Palmonari, F.; Papi, A.; Park, I.H.; Pauluzzi, M.; Pauss, F.; Perrin, E.; Pesci, A.; Pevsner, A.; Pimenta, M.; Plyaskin, V.; Pojidaev, V.; Postolache, V.; Produit, N.; Rancoita, P.G.; Rapin, D.; Raupach, F.; Ren, D.; Ren, Z.; Ribordy, M.; Richeux, J.P.; Riihonen, E.; Ritakari, J.; Roeser, U.; Roissin, C.; Sagdeev, R.; Sartorelli, G.; Schultz von Dratzig, A.; Schwering, G.; Scolieri, G.; Seo, E.S.; Shoutko, V.; Shoumilov, E.; Siedling, R.; Son, D.; Song, T.; Steuer, M.; Sun, G.S.; Suter, H.; Tang, X.W.; Ting, S.C.C.Samuel C.C.; Ting, S.M.; Tornikoski, M.; Torsti, J.; Tr umper, J.; Ulbricht, J.; Urpo, S.; Usoskin, I.; Valtonen, E.; Vandenhirtz, J.; Velcea, F.; Velikhov, E.; Verlaat, B.; Vetlitsky, I.; Vezzu, F.; Vialle, J.P.; Viertel, G.; Vite, D.; Gunten, H. Von; Wicki, S.W.S. Waldmeier; Wallraff, W.; Wang, B.C.; Wang, J.Z.; Wang, Y.H.; Wiik, K.; Williams, C.; Wu, S.X.; Xia, P.C.; Yan, J.L.; Yan, L.G.; Yang, C.G.; Yang, M.; Ye, S.W.; Yeh, P.; Xu, Z.Z.; Zhang, H.Y.; Zhang, Z.P.; Zhao, D.X.; Zhu, G.Y.; Zhu, W.Z.; Zhuang, H.L.; Zichichi, A.; Zimmermann, B.

    2002-01-01

    The Alpha Magnetic Spectrometer (AMS) is a large acceptance (0.65 sr m 2 ) detector designed to operate in the International Space Station (ISS) for three years. The purposes of the experiment are to search for cosmic antimatter and dark matter and to study the composition and energy spectrum of the primary cosmic rays. A 'scaled-down' version has been flown on the Space Shuttle Discovery for 10 days in June 1998. The complete AMS is programmed for installation on the ISS in October 2003 for an operational period of 3 yr. This contribution reports on the experimental configuration that will be installed on the ISS

  18. A Grande Reportagem no contexto informativo SIC

    Colaço, Vanessa Alexandra Francisco

    2014-01-01

    Os telespectadores querem ver grandes reportagens? Como evoluíram as audiências da Grande Reportagem SIC? É este o produto premium da estação? Terá este formato um investimento e continuidade garantidas? Estas são algumas das questões formuladas e às quais se procurou dar resposta neste Relatório de Estágio. Neste trabalho traça-se o perfil do programa Grande Reportagem SIC, clarificando a linha editorial que lhe serviu de base, procurando perceber as suas dinâmicas e passando em revista mome...

  19. Supersymmetry and supergravity: Phenomenology and grand unification

    Arnowitt, R.; Nath, P.

    1993-01-01

    A survey is given of supersymmetry and supergravity and their phenomenology. Some of the topics discussed are the basic ideas of global supersymmetry, the minimal supersymmetric Standard Model (MSSM) and its phenomenology, the basic ideas of local supersymmetry (supergravity), grand unification, supersymmetry breaking in supergravity grand unified models, radiative breaking of SU(2) x U(1), proton decay, cosmological constraints, and predictions of supergravity grand unified models. While the number of detailed derivations are necessarily limited, a sufficient number of results are given so that a reader can get a working knowledge of this field

  20. Crystal-diffraction spectrometer of increased efficiency

    Saukov, A.I.; Gornitsyn, G.A.; Morozov, N.A.

    1985-01-01

    The geometry of the spectrometer is illustrated in this paper. An attempt is made to achieve optimal design of the spectrometer by finding the coefficient of reflection of the gamma radiation from the various Ge planes. In these experiments, the Du Mond design was used in the spectrometer. Illustrations are provided to explain dependence of the relative efficiency upon the energy of the gamma quanta

  1. Digital Spectrometers for Interplanetary Science Missions

    Jarnot, Robert F.; Padmanabhan, Sharmila; Raffanti, Richard; Richards, Brian; Stek, Paul; Werthimer, Dan; Nikolic, Borivoje

    2010-01-01

    A fully digital polyphase spectrometer recently developed by the University of California Berkeley Wireless Research Center in conjunction with the Jet Propulsion Laboratory provides a low mass, power, and cost implementation of a spectrum channelizer for submillimeter spectrometers for future missions to the Inner and Outer Solar System. The digital polyphase filter bank spectrometer (PFB) offers broad bandwidth with high spectral resolution, minimal channel-to-channel overlap, and high out-of-band rejection.

  2. Intracavity Laser Photoacoustic Spectrometer with High Sensitivity

    Mitrayana; Muslim; Wasono, M.A.J.

    2002-01-01

    A photo acoustic spectrometer set-up has been upgraded from an extra cavity into an intracavity configuration using a sealed-off CO 2 laser as the spectrometer's radiation source. The detection level of the upgrade Intracavity Photoacoustic Spectrometer (IPS) reached (200 ± 50) ppt for C 2 H 4 and (20 ± 5) ppt for SF 6 with response time (6.6 ± 0.2) s. (author)

  3. Functional Enhancements in Used Oil Analysis Spectrometers

    Lukas, Malte

    1998-01-01

    Spark emission spectrometers using the rotating disk electrode (RDE) technique have become the workhorses and primary analytical tool of most machine condition monitoring programs based on oil analysis...

  4. Las cinco grandes dimensiones de la personalidad

    Jan ter Laak

    1996-12-01

    Full Text Available Este artículo revisa las distintas posiciones teóricas sobre las cinco grandes dimensiones de la personalidad, mostrando las semejanzas y diferencias entre las posturas teóricas. Esta contribución presenta lo siguiente: (a la génesis del contenido y la estructura de las cinco dimensiones; (b la fortaleza de las cinco dimensiones; (e la relación de las cinco grandes dimensiones con otros constructos de personalidad; (d discute el valor predictivo de las puntuaciones del perfil de las cinco dimensiones para criterios pertinentes; (e analiza el estatus teórico de las cinco dimensiones; (f discute críticas históricas sobre las cinco grandes dimensiones y se formulan respuestas a estas críticas; (g hace conjeturas para el futuro de las cinco grandes dimensiones; y (h concluye con algunas conclusiones y comentarios.

  5. Grand unification and gravity - selected topics

    Zee, A.

    1981-09-01

    The material given here was presented in lectures delivered at the 4th Kyoto Summer Institute on Grand Unification and Related Topics. It consists of six sections. The sections are: the family problem, fermion mass hierarchy, maximal local symmetry, operator analysis of new physics, dynamically generated gravity, and Kaluza theory and grand unification. The last section contains a (hopefully) pedagogical introduction to Kaluza theory. For pedagogical completeness, several appendices reviewing some elementary notions of differential geometry have been added

  6. Airborne gamma-ray spectrometer and magnetometer survey: north/south tieline. Final report

    1981-05-01

    An airborne high sensitivity gamma-ray spectrometer and magnetometer survey was conducted along the 99 0 longitude meridian from the Canadian border southward to the Mexican border. A total of 1555 line miles of geophysical data were acquired and, subsequently, compiled. The north-south tieline was flown as part of the National Uranium Resources Evaluation. NURE is a program of the US Department of Energy's Grand Junction, Colorado, office to acquire and compile geologic and other information with which to assess the magnitude and distribution of uranium resources and to determine areas favorable for the occurrence of uranium in the United States

  7. Imaging spectrometers for atmosphere monitoring

    Reinert, Thido; Bovensmann, Heinrich; Münzenmayer, Ralf; Weiss, Stefan; Posselt, Winfried

    2017-11-01

    Atmospheric monitoring missions aim at products like O3, H2O, NO2, SO2, BrO, CH4, CO, CO2 as well as aerosols and cloud information. Depending on the application area (Ozone Monitoring, Green House Gas Monitoring, Tropospheric Composition and Air Quality, Chemistry Climate Interaction etc.) total or tropospheric columns as well as profile information is required. The user community of these data as well as their central requirements w.r.t. the payload aspects will be described. A large range of relevant passive instrument types is available, in particular imaging spectrometer, sounder and polarisation measuring systems in the UV-VIS, SWIR and TIR spectral range. Differences between instruments for dedicated missions are highlighted and evolution of requirements is explained, also in comparison with relevant existing instrumentation partly in orbit today. Aspects of technology roadmaps for instrument implementation as well as synergetic effects of instrument combinations and according mission scopes are discussed.

  8. Time-of-flight spectrometers

    Carrico, J.P.

    1976-01-01

    The flight time of an ion in an inhomogeneous, oscillatory electric field (IOFE) is an m/e-dependent property of this field and is independent of the initial position and velocity. The d.c. component of the equation of motion for an ion in the IOFE describes a harmonic oscillation of constant period. When ions oscillate for many periods with one species overtaking another the motion may no longer be truly periodic although the resulting period or 'quasi-period' still remains independent of the initial conditions. This period or 'quasi-period' is used in the time-of-flight mass spectrometer described. The principle of operation is also described and both analytical and experimental results are reported. (B.D.)

  9. Neutron measurement by transportable spectrometer

    Anon.

    1990-01-01

    Two levels of neutron spectrometry are in regular use at nuclear power plants: some techniques used in the laboratory produce detailed spectra but require specialist operators, while simple instruments used by non-specialists to measure the neutron dose-rate to operators provide little spectral information. The standard portable instruments are therefore of no use when anomalous readings are obtained which require further investigation. AEA Technology at Winfrith has developed a Transportable Neutron Spectrometer (TNS) which is designed to produce reasonable spectra in routine use by staff with no specialist skill in spectroscopy, and high-quality spectra in the hands of skilled staff. The TNS provides a level of information intermediate between those currently available, and is also designed to solve the problem of imperfect dose response which is common in portable dosimeters. The TNS system consists of a power supply, a probe and a signal processing and data acquisition unit. (author)

  10. The BNL multiparticle spectrometer software

    Saulys, A.C.

    1985-01-01

    This paper discusses some solutions to problems common to the design, management and maintenance of a large high energy physics spectrometer software system. The experience of dealing with a large, complex program and the necessity of having the programm controlled by various people at different levels of computer experience has led us to design a program control structure of mnemonic and self-explanatory nature. The use of this control language in both ''on-line'' and ''off-line'' operation of the program will be discussed. The solution of structuring a large program for modularity so that substantial changes to the program can be made easily for a wide variety of high energy physics experiments is discussed. Specialized tools for this type of large program management are also discussed. (orig.)

  11. The Geostationary Fourier Transform Spectrometer

    Key, Richard; Sander, Stanley; Eldering, Annmarie; Blavier, Jean-Francois; Bekker, Dmitriy; Manatt, Ken; Rider, David; Wu, Yen-Hung

    2012-01-01

    The Geostationary Fourier Transform Spectrometer (GeoFTS) is an imaging spectrometer designed for a geostationary orbit (GEO) earth science mission to measure key atmospheric trace gases and process tracers related to climate change and human activity. GEO allows GeoFTS to continuously stare at a region of the earth for frequent sampling to capture the variability of biogenic fluxes and anthropogenic emissions from city to continental spatial scales and temporal scales from diurnal, synoptic, seasonal to interannual. The measurement strategy provides a process based understanding of the carbon cycle from contiguous maps of carbon dioxide (CO2), methane (CH4), carbon monoxide (CO), and chlorophyll fluorescence (CF) collected many times per day at high spatial resolution (2.7kmx2.7km at nadir). The CO2/CH4/CO/CF measurement suite in the near infrared spectral region provides the information needed to disentangle natural and anthropogenic contributions to atmospheric carbon concentrations and to minimize uncertainties in the flow of carbon between the atmosphere and surface. The half meter cube size GeoFTS instrument is based on a Michelson interferometer design that uses all high TRL components in a modular configuration to reduce complexity and cost. It is self-contained and as independent of the spacecraft as possible with simple spacecraft interfaces, making it ideal to be a "hosted" payload on a commercial communications satellite mission. The hosted payload approach for measuring the major carbon-containing gases in the atmosphere from the geostationary vantage point will affordably advance the scientific understating of carbon cycle processes and climate change.

  12. Fluorescence imaging spectrometer optical design

    Taiti, A.; Coppo, P.; Battistelli, E.

    2015-09-01

    The optical design of the FLuORescence Imaging Spectrometer (FLORIS) studied for the Fluorescence Explorer (FLEX) mission is discussed. FLEX is a candidate for the ESA's 8th Earth Explorer opportunity mission. FLORIS is a pushbroom hyperspectral imager foreseen to be embarked on board of a medium size satellite, flying in tandem with Sentinel-3 in a Sun synchronous orbit at a height of about 815 km. FLORIS will observe the vegetation fluorescence and reflectance within a spectral range between 500 and 780 nm. Multi-frames acquisitions on matrix detectors during the satellite movement will allow the production of 2D Earth scene images in two different spectral channels, called HR and LR with spectral resolution of 0.3 and 2 nm respectively. A common fore optics is foreseen to enhance by design the spatial co-registration between the two spectral channels, which have the same ground spatial sampling (300 m) and swath (150 km). An overlapped spectral range between the two channels is also introduced to simplify the spectral coregistration. A compact opto-mechanical solution with all spherical and plane optical elements is proposed, and the most significant design rationales are described. The instrument optical architecture foresees a dual Babinet scrambler, a dioptric telescope and two grating spectrometers (HR and LR), each consisting of a modified Offner configuration. The developed design is robust, stable vs temperature, easy to align, showing very high optical quality along the whole field of view. The system gives also excellent correction for transverse chromatic aberration and distortions (keystone and smile).

  13. The MIRI Medium Resolution Spectrometer calibration pipeline

    Labiano, A.; Azzollini, R.; Bailey, J.; Beard, S.; Dicken, D.; García-Marín, M.; Geers, V.; Glasse, A.; Glauser, A.; Gordon, K.; Justtanont, K.; Klaassen, P.; Lahuis, F.; Law, D.; Morrison, J.; Müller, M.; Rieke, G.; Vandenbussche, B.; Wright, G.

    2016-01-01

    The Mid-Infrared Instrument (MIRI) Medium Resolution Spectrometer (MRS) is the only mid-IR Integral Field Spectrometer on board James Webb Space Telescope. The complexity of the MRS requires a very specialized pipeline, with some specific steps not present in other pipelines of JWST instruments,

  14. Polarized epithermal neutron spectrometer at KENS

    Kohgi, M.

    1983-01-01

    A spectrometer employing a white, epithermal, polarized neutron beam is under construction at KENS. The neutron polarization is achieved by passage through a dynamically polarized proton filter (DPPF). The results of the test experiments show that the DPPF method is promising in obtaining polarized epithermal neutron beam. The basic design of the spectrometer is described

  15. RCNP E398 {sup 16}O,{sup 12}C(p,p’) experiment: Measurement of the γ-ray emission probability from giant resonances in relation to {sup 16}O,{sup 12}C(ν,ν’) reactions

    Ou, I.; Yamada, Y.; Mori, T.; Yano, T.; Sakuda, M. [Department of Physics, Okayama University, Okayama 700-8530 (Japan); Tamii, A.; Suzuki, T.; Yosoi, M.; Aoi, N.; Ideguchi, E.; Hashimoto, T.; Miki, K.; Ito, T.; Iwamoto, C.; Yamamoto, T. [Research Center for Nuclear Physics (RCNP), Osaka University, Ibaraki, Osaka 567-0047 (Japan); Akimune, H. [Department of Physics, Konan University, Okamoto 8-9-1, Higashinada, Kobe 658-8501 (Japan)

    2015-05-15

    We propose to measure the γ-ray emission probability from excited states above 5 MeV including giant resonance of {sup 16}O and {sup 12}C as a function of excitation energy in 1-MeV step. Here, we measure both the excitation energy (E{sub x}=5-30MeV) at the forward scattering angles (0°-3°) of the {sup 16}O, {sup 12}C (p, p’) reaction using Grand-Raiden Spectrometer and the energy of γ-rays (E{sub γ}) using an array of NaI(Tl) counters. The purpose of the experiment is to provide the basic and important information not only for the γ-ray production from primary neutral-current neutrino-oxygen (-carbon) interactions but also for that from the secondary hadronic (neutron-oxygen and -carbon) interactions.

  16. Gamma decay of pygmy states in 90,94Zr from inelastic scattering of light ions

    Crespi, F. C. L.; Bracco, A.; Tamii, A.; Blasi, N.; Camera, F.; Wieland, O.; Aoi, N.; Balabanski, D.; Bassauer, S.; Brown, A. S.; Carpenter, M. P.; Carroll, J. J.; Ciemala, M.; Czeszumska, A.; Davies, P. J.; Donaldson, L.; Fang, Y.; Fujita, H.; Gey, G.; Hoang, T. H.; Ichige, N.; Ideguchi, E.; Inoue, A.; Isaak, J.; Iwamoto, C.; Jenkins, D. G.; Jin, O. H.; Klaus, T.; Kobayashi, N.; Koike, T.; Krzysiek, M.; Raju, M. Kumar; Liu, M.; Maj, A.; Montanari, D.; Morris, L.; Noji, S.; Pickstone, S. G.; Savran, D.; Spieker, M.; Steinhilber, G.; Sullivan, C.; Wasilewska, B.; Werner, V.; Yamamoto, T.; Yamamoto, Y.; Zhou, X.; Zhu, S.

    2018-05-01

    We performed experiments to study the low-energy part of the E1 response (Pygmy Dipole Resonance) in 90,94Zr nuclei, by measuring the (p,p’γ) and (α,α’γ) inelastic scattering reactions at energies Ebeam,p = 80 MeV and Ebeam,α = 130 MeV respectively. The inelastically scattered particles were measured by employing the high-resolution spectrometer Grand Raiden. The gamma-rays emitted following the de-excitation of the Zr target nuclei were detected using both the clover type HPGe detectors of the CAGRA array and the large volume LaBr3:Ce scintillation detectors from the HECTOR+ array. Some preliminary results are presented here.

  17. 2010 Panel on the Biomaterials Grand Challenges

    Reichert, William “Monty”; Ratner, Buddy D.; Anderson, James; Coury, Art; Hoffman, Allan S.; Laurencin, Cato T.; Tirrell, David

    2014-01-01

    In 2009, the National Academy for Engineering issued the Grand Challenges for Engineering in the 21st Century comprised of 14 technical challenges that must be addressed to build a healthy, profitable, sustainable, and secure global community (http://www.engineeringchallenges.org). Although crucial, none of the NEA Grand Challenges adequately addressed the challenges that face the biomaterials community. In response to the NAE Grand Challenges, Monty Reichert of Duke University organized a panel entitled Grand Challenges in Biomaterials at the at the 2010 Society for Biomaterials Annual Meeting in Seattle. Six members of the National Academies—Buddy Ratner, James Anderson, Allan Hoffman, Art Coury, Cato Laurencin, and David Tirrell—were asked to propose a grand challenge to the audience that, if met, would significantly impact the future of biomaterials and medical devices. Successfully meeting these challenges will speed the 60-plus year transition from commodity, off-the-shelf biomaterials to bioengineered chemistries, and biomaterial devices that will significantly advance our ability to address patient needs and also to create new market opportunities. PMID:21171147

  18. Handheld spectrometers: the state of the art

    Crocombe, Richard A.

    2013-05-01

    "Small" spectrometers fall into three broad classes: small versions of laboratory instruments, providing data, subsequently processed on a PC; dedicated analyzers, providing actionable information to an individual operator; and process analyzers, providing quantitative or semi-quantitative information to a process controller. The emphasis of this paper is on handheld dedicated analyzers. Many spectrometers have historically been large, possible fragile, expensive and complicated to use. The challenge over the last dozen years, as instruments have moved into the field, has been to make spectrometers smaller, affordable, rugged, easy-to-use, but most of all capable of delivering actionable results. Actionable results can dramatically improve the efficiency of a testing process and transform the way business is done. There are several keys to this handheld spectrometer revolution. Consumer electronics has given us powerful mobile platforms, compact batteries, clearly visible displays, new user interfaces, etc., while telecomm has revolutionized miniature optics, sources and detectors. While these technologies enable miniature spectrometers themselves, actionable information has demanded the development of rugged algorithms for material confirmation, unknown identification, mixture analysis and detection of suspicious materials in unknown matrices. These algorithms are far more sophisticated than the `correlation' or `dot-product' methods commonly used in benchtop instruments. Finally, continuing consumer electronics advances now enable many more technologies to be incorporated into handheld spectrometers, including Bluetooth, wireless, WiFi, GPS, cameras and bar code readers, and the continued size shrinkage of spectrometer `engines' leads to the prospect of dual technology or `hyphenated' handheld instruments.

  19. High-Resolution Mass Spectrometers

    Marshall, Alan G.; Hendrickson, Christopher L.

    2008-07-01

    Over the past decade, mass spectrometry has been revolutionized by access to instruments of increasingly high mass-resolving power. For small molecules up to ˜400 Da (e.g., drugs, metabolites, and various natural organic mixtures ranging from foods to petroleum), it is possible to determine elemental compositions (CcHhNnOoSsPp…) of thousands of chemical components simultaneously from accurate mass measurements (the same can be done up to 1000 Da if additional information is included). At higher mass, it becomes possible to identify proteins (including posttranslational modifications) from proteolytic peptides, as well as lipids, glycoconjugates, and other biological components. At even higher mass (˜100,000 Da or higher), it is possible to characterize posttranslational modifications of intact proteins and to map the binding surfaces of large biomolecule complexes. Here we review the principles and techniques of the highest-resolution analytical mass spectrometers (time-of-flight and Fourier transform ion cyclotron resonance and orbitrap mass analyzers) and describe some representative high-resolution applications.

  20. A semiconductor beta ray spectrometer

    Bom, V.R.

    1987-01-01

    Measurement of energy spectra of beta particles emitted from nuclei in beta-decay processes provides information concerning the mass difference of these nuclei between initial and final state. Moreover, experimental beta spectra yield information on the feeding of the levels in the daughter nucleus. Such data are valuable in the construction and checking of the level schemes. This thesis describes the design, construction, testing and usage of a detector for the accurate measurement of the mentioned spectra. In ch. 2 the design and construction of the beta spectrometer, which uses a hyper-pure germanium crystal for energy determination, is described. A simple wire chamber is used to discriminate beta particles from gamma radiation. Disadvantages arise from the large amounts of scattered beta particles deforming the continua. A method is described to minimize the scattering. In ch. 3 some theoretical aspects of data analysis are described and the results of Monte-Carlo simulations of the summation of annihilation radiation are compared with experiments. Ch. 4 comprises the results of the measurements of the beta decay energies of 103-108 In. 87 refs.; 34 figs.; 7 tabs

  1. High intensity TOF spectrometer for cold neutrons

    Maayouf, R.M.; Abd El-Kawy, A.; Habib, N.; Adib, M.; Hamouda, I.

    1984-01-01

    This work presents a neutron time-of-flight (TOF) spectrometer developed specially for total neutron cross-section measurements at neutron energies below 5 MeV and sample's temperature varying from the liquid nitrogen one and up to 500 0 K. The spectrometer is equipped by remote control unit, designed especially, in order to move the sample in and out of the beam during the experimental measurements. The spectrometer has proved to be useful for transmission measurements at neutron energies below 5 MeV. It has a reasonable energy resolution (4.4%) and high effect to background ratio (11.1) at 5 MeV

  2. RITA: The reinvented triple axis spectrometer

    Mason, T.E. [Toronto Univ., ON (Canada). Dept. of Physics; Clausen, K.N.; Aeppli, G.; McMorrow, D.R.; Kjems, J.K. [Risoe National Lab., Roskilde (Denmark)

    1995-11-01

    Risoe National Laboratory was reported to be in the process of developing a new spectrometer design, RITA, based on the triple axis design. The spectrometer will attempt to incorporate more recent innovations such as multilayer supermirrors and microstrip proportional counters into a rethinking of the triple-axis spectrometer. By optimizing the beam optics, using supermirrors and extending the analyser to map regions of (Q, {omega}) space using an array of independently controllable pyrolytic graphite crystals focussed on an area detector, it was hoped that the efficiency of single-crystal inelastic experiments could be increased by as much as a factor of 20. 7 figs., 20 refs.

  3. Effective Higgs theories in supersymmetric grand unification

    Zheng, Sibo [Chongqing University, Department of Physics, Chongqing (China)

    2017-09-15

    The effective Higgs theories at the TeV scale in supersymmetric SU(5) grand unification models are systematically derived. Restricted to extensions on 5{sub H} containing the Higgs sector we show that only two types of real (vector-like) models and one type of chiral model are found to be consistent with perturbative grand unification. While the chiral model has been excluded by the LHC data, the fate of perturbative unification will be uniquely determined by the two classes of vector-like models. (orig.)

  4. Grand Tour: immaginario, territorio e culture digitali

    Emiliano Ilardi

    2016-12-01

    Full Text Available Il Grand Tour può essere recuperato come asset narrativo utile per un intervento strategico di re-branding del viaggio in Italia? Il contributo analizza il contesto e le condizioni per una progettazione di questo livello nell’ambiente culturale dell’epoca digitale. Considerando gli archetipi moderni della mediazione dei luoghi come una grande riserva di senso, da riattivare sia nelle pratiche basate sui format seriali e transmediali che valorizzano i territori nella produzione creativa, sia nella costruzione di infrastrutture digitali e  transluoghi per la valorizzazione degli attrattori culturali.

  5. A Unified Grand Tour of Theoretical Physics

    Lawrie, Ian D

    2002-01-01

    A unified account of the principles of theoretical physics, A Unified Grand Tour of Theoretical Physics, Second Edition stresses the inter-relationships between areas that are usually treated as independent. The profound unifying influence of geometrical ideas, the powerful formal similarities between statistical mechanics and quantum field theory, and the ubiquitous role of symmetries in determining the essential structure of physical theories are emphasized throughout.This second edition conducts a grand tour of the fundamental theories that shape our modern understanding of the physical wor

  6. Multidetector calibration for mass spectrometers

    Bayne, C.K.; Donohue, D.L.; Fiedler, R.

    1994-06-01

    The International Atomic Energy Agency's Safeguards Analytical Laboratory has performed calibration experiments to measure the different efficiencies among multi-Faraday detectors for a Finnigan-MAT 261 mass spectrometer. Two types of calibration experiments were performed: (1) peak-shift experiments and (2) peak-jump experiments. For peak-shift experiments, the ion intensities were measured for all isotopes of an element in different Faraday detectors. Repeated measurements were made by shifting the isotopes to various Faraday detectors. Two different peak-shifting schemes were used to measure plutonium (UK Pu5/92138) samples. For peak-jump experiments, ion intensities were measured in a reference Faraday detector for a single isotope and compared with those measured in the other Faraday detectors. Repeated measurements were made by switching back-and-forth between the reference Faraday detector and a selected Faraday detector. This switching procedure is repeated for all Faraday detectors. Peak-jump experiments were performed with replicate measurements of 239 Pu, 187 Re, and 238 U. Detector efficiency factors were estimated for both peak-jump and peak-shift experiments using a flexible calibration model to statistically analyze both types of multidetector calibration experiments. Calculated detector efficiency factors were shown to depend on both the material analyzed and the experimental conditions. A single detector efficiency factor is not recommended for each detector that would be used to correct routine sample analyses. An alternative three-run peak-shift sample analysis should be considered. A statistical analysis of the data from this peak-shift experiment can adjust the isotopic ratio estimates for detector differences due to each sample analysis

  7. The VERDI fission fragment spectrometer

    Frégeau M.O.

    2013-12-01

    Full Text Available The VERDI time-of-flight spectrometer is dedicated to measurements of fission product yields and of prompt neutron emission data. Pre-neutron fission-fragment masses will be determined by the double time-of-flight (TOF technique. For this purpose an excellent time resolution is required. The time of flight of the fragments will be measured by electrostatic mirrors located near the target and the time signal coming from silicon detectors located at 50 cm on both sides of the target. This configuration, where the stop detector will provide us simultaneously with the kinetic energy of the fragment and timing information, significantly limits energy straggling in comparison to legacy experimental setup where a thin foil was usually used as a stop detector. In order to improve timing resolution, neutron transmutation doped silicon will be used. The high resistivity homogeneity of this material should significantly improve resolution in comparison to standard silicon detectors. Post-neutron fission fragment masses are obtained form the time-of-flight and the energy signal in the silicon detector. As an intermediary step a diamond detector will also be used as start detector located very close to the target. Previous tests have shown that poly-crystalline chemical vapour deposition (pCVD diamonds provides a coincidence time resolution of 150 ps not allowing complete separation between very low-energy fission fragments, alpha particles and noise. New results from using artificial single-crystal diamonds (sCVD show similar time resolution as from pCVD diamonds but also sufficiently good energy resolution.

  8. View of the Axial Field Spectrometer

    1980-01-01

    The Axial Field Spectrometer, with the vertical uranium/scintillator calorimeter and the central drift chamber retracted for service. One coil of the Open Axial Field Magnet is just visible to the right.

  9. ISLA: An Isochronous Spectrometer with Large Acceptances

    Bazin, D., E-mail: bazin@nscl.msu.edu; Mittig, W.

    2013-12-15

    A novel type of recoil mass spectrometer and separator is proposed for the future secondary radioactive beams of the ReA12 accelerator at NSCL/FRIB, inspired from the TOFI spectrometer developed at the Los Alamos National Laboratory for online mass measurements. The Isochronous Spectrometer with Large Acceptances (ISLA) is able to achieve superior characteristics without the compromises that usually plague the design of large acceptance spectrometers. ISLA can provide mass-to-charge ratio (m/q) measurements to better than 1 part in 1000 by using an optically isochronous time-of-flight independent of the momentum vector of the recoiling ions, despite large acceptances of 20% in momentum and 64 msr in solid angle. The characteristics of this unique design are shown, including requirements for auxiliary detectors around the target and the various types of reactions to be used with the re-accelerated radioactive beams of the future ReA12 accelerator.

  10. Computer control in a compton scattering spectrometer

    Cui Ningzhuo; Chen Tao; Gong Zhufang; Yang Baozhong; Mo Haiding; Hua Wei; Bian Zuhe

    1995-01-01

    The authors introduced the hardware and software of computer autocontrol of calibration and data acquisition in a Compton Scattering spectrometer which consists of a HPGe detector, Amplifiers and a MCA

  11. Electrostatic Spectrometer for Mars Rover Wheel

    National Aeronautics and Space Administration — Develop a simple electrostatic spectrometer that can be mounted on the wheels of a Mars rover to continuously and unobtrusively determine the mineral composition and...

  12. Low Power FPGA Based Spectrometer, Phase I

    National Aeronautics and Space Administration — We propose to design a general purpose reconfigurable wide bandwidth spectrometer for use in NASA's passive microwave missions, deep space network and radio...

  13. High-resolution spectrometer at PEP

    Weiss, J.M.; HRS Collaboration.

    1982-01-01

    A description is presented of the High Resolution Spectrometer experiment (PEP-12) now running at PEP. The advanced capabilities of the detector are demonstrated with first physics results expected in the coming months

  14. Remote UV Fluorescence Lifetime Spectrometer, Phase II

    National Aeronautics and Space Administration — The goal of this project is to develop, demonstrate, and deliver to NASA an innovative, portable, and power efficient Remote UV Fluorescence Lifetime Spectrometer...

  15. The electronic system of Beijing spectrometer

    Xi Deming

    1990-01-01

    Beijing Spectrometer (BES) in an experimental facility of high energy physics on Beijing Electron Positron Collider (BEPC). A brief description including the global design, the read out circuits, the performances and the recent status of its electronic system is presented

  16. RITA-type triple axis spectrometers

    Roennow, H.M.

    2001-01-01

    The RITA spectrometer at Risoe National Laboratory was the first to incorporate a complete re-thinking of the neutron-path from source, through detector to analysis. Since then, other RITA-type spectrometers such as SPINS at NIST, RITA-II at PSI have been built, and several new spectrometers around the world are adapting the same philosophy. The main novelty of RITA was the introduction of a single back-end tank featuring both an analyser block with multiple individually turnable analyser blades and a 2D position sensitive detector. Several new triple-axis spectrometers are presently being built at existing and future sources, and almost all of them have learnt from the experience with RITA. (R.P.)

  17. Design and construction of a NIR spectrometer

    Barcala-Riveira, J M; Fernandez-Marron, J L; Molero-Menendez, F; Navarrete-Marin, J J; Oller-Gonzalez, J C

    2003-01-01

    This document describes the design and construction of a NIR spectrometer based on an acoustic-optic tunable filter. The spectrometer will be used for automatic identification of plastics in domestic waste. The system works between 1200 and 1800 nm. Instrument is controlled by a personal computer. Computer receives and analyses data. A software package has been developed to do these tasks. (Author) 27 refs.

  18. Silicon spectrometer with a Peltier refrigerator

    Belcarz, E.; Chwaszczewska, J.; Hahn, G.; Nowicki, W.; Sawicka, B.; Skoczek, K.; Slapa, M.; Szymczak, M.

    1974-01-01

    This paper describes a spectrometer with a Si(Li) detector cooled by a Peltier refrigerator. The spectrometer is able to analyse samples of practically all most frequently encountered emitters of alpha, beta and low energy gamma radiation. The energy resolution were about 1.3-1.5 keV for 14 keV gamma radiation. The system can also operate in field conditions in the fluorescence analysis. (author)

  19. Design and construction of a NIR spectrometer

    Barcala Riveira, J. M.; Fernandez Marron, J. L.; Alberdi Primicia, J.; Molero Menendez, F.; Navarrete Marin, J. J.; Oller Gonzalez, J. C.

    2003-01-01

    This document describes the design and construction of a NIR spectrometer based on an acoustic-optic tunable filter. The spectrometer will be used for automatic identification of plastics in domestic waste. The system works between 1200 and 1800 nm. Instrument is controlled by a personal computer. Computer receives and analyses data. A software package has been developed to do these tasks. (Author) 27 refs

  20. 1987 calibration of the TFTR neutron spectrometers

    Barnes, C.W.; Strachan, J.D.; Princeton Univ., NJ

    1989-12-01

    The 3 He neutron spectrometer used for measuring ion temperatures and the NE213 proton recoil spectrometer used for triton burnup measurements were absolutely calibrated with DT and DD neutron generators placed inside the TFTR vacuum vessel. The details of the detector response and calibration are presented. Comparisons are made to the neutron source strengths measured from other calibrated systems. 23 refs., 19 figs., 6 tabs

  1. Fast-response personal Moessbauer spectrometer

    Kholmetskij, A.L.; Mashlan, M.; Misevich, O.V.; Evdokimov, V.A.; Lopatik, A.R.; Zhak, D.; Fedorov, A.A.; Snashel, V.

    1995-01-01

    Spectrometer design to record transmission Moessbauer spectra is described. The spectrometer consists of PC/AT computer with 1 mb memory and 40 mb hard disk, of EPSON LX 850 printer, of color monitor with VGA graphical adapter, of data accumulation system, of speed generator, of motion system with minivibrator, of scintillation detector with YA10 3 :Ce scintillator, of single-channel amplitude analyzer, of measuring bench and of 57 Co(Rh) source. 1 ref.; 1 fig

  2. The BTeV main spectrometer

    Sheldon, P.D.

    2001-01-01

    BTeV is a second generation B-factory experiment that will use a double-arm, forward spectrometer in the C0 experimental hall at the Fermilab Tevatron. I will describe the motivation and design of the 'main spectrometer', consisting of a ring-imaging Cherenkov system for charged particle identification, an electromagnetic calorimeter of lead-tungstate crystals, a proportional tube muon system with magnetized filtering steel, and a straw-tube and silicon strip charged particle tracking system

  3. Recent ion optics and mass spectrometers

    Matsuda, Hisashi

    1976-01-01

    The establishment of the third order approximation method for computing the orbit of the ion optical system for mass spectrometers and the completion of its computer program are reported. A feature of this orbit computation is in that the effect of the fringing field can be considered with the accuracy of third order approximation. Several new ion optical systems for mass spectrometers have been proposed by using such orbit computing programs. Brief explanation and the description on the future prospect and problems are made on the following items: the vertual image double focusing mass spectrometer, the second order double focusing mass spectrometer, the E x B superposed field mass spectrometer, and the apparatus with a cylindrical electric field and Q-lens. In the E x B superposed field with Matsuda plates, if the magnetic field is generated by an electromagnet instead of a permanent magnet, the dispersion of mass and energy can be changed at will. The Matsuda plates are known as the auxiliary electrodes positioned at the top and bottom of a cylindrical capacitor. Utilizing those characteristics, a zoom spectrometer can be made, with which only a necessary part of mass spectra can be investigated in detail, but the whole spectra are investigated roughly. In addition, the distribution of energy can be investigated simultaneously after the separation of ionic mass similarly to the parabola apparatus. (Iwakiri, K.)

  4. Study of neutron spectrometers for ITER

    Kaellne, Jan

    2005-11-15

    A review is presented of the developments in the field of neutron emission spectrometry (NES) which is of relevance for identifying the role of NES diagnostics on ITER and selecting suitable instrumentation. Neutron spectrometers will be part of the ITER neutron diagnostic complement and this study makes a special effort to examine which performance characteristics the spectrometers should possess to provide the best burning plasma diagnostic information together with neutron cameras and neutron yield monitors. The performance of NES diagnostics is coupled to how much interface space can be provided which has lead to an interest to find compact instruments and their NES capabilities. This study assesses all known spectrometer types of potential interest for ITER and makes a ranking of their performance (as demonstrated or projected), which, in turn, are compared with ITER measurement requirements as a reference; the ratio of diagnostic performance to interface cost for different spectrometers is also discussed for different spectrometer types. The overall result of the study is an assessment of which diagnostic functions neutron measurements can provide in burning plasma fusion experiments on ITER and the role that NES can play depending on the category of instrument installed. Of special note is the result that much higher quality diagnostic information can be obtained from neutron measurements with total yield monitors, profile flux cameras and spectrometers when the synergy in the data is considered in the analysis and interpretation.

  5. Hilbert's Grand Hotel with a series twist

    Wijeratne, Chanakya; Mamolo, Ami; Zazkis, Rina

    2014-08-01

    This paper presents a new twist on a familiar paradox, linking seemingly disparate ideas under one roof. Hilbert's Grand Hotel, a paradox which addresses infinite set comparisons is adapted and extended to incorporate ideas from calculus - namely infinite series. We present and resolve several variations, and invite the reader to explore his or her own variations.

  6. "Teine" võitis Prantsusmaal Grand Prix'

    2006-01-01

    Prantsusmaal Essonne'is toimuval 8. Euroopa filmifestivalil Cinessonne sai üliõpilaste žürii grand prix rahvusvahelises ühistöös valminud tantsufilm "Teine" ("Another") : režissöör Rene Vilbre. Ka teistest festivalidest, kus film osalenud

  7. The Virtual Grand Tour as Educational Paradigm

    Hansen, Per Skafte; Mouritsen, Lars

    2001-01-01

    The Virtual Grand Tour as defined here bears some resemblance to its 18th century ancestor: a wide range of individual topics are treated as a whole; a tutor, whether real or simulated, present or remote, is provided; a set of problem solving tools forms an integrated part of the "traveller...

  8. Grand Prix Eurovision: Eine Fankultur im Medienzeitalter

    Heinz Moser

    2017-06-01

    Full Text Available Der Grand Prix Eurovision ist seit Jahrzehnten eine der bekanntesten Unterhaltungssendungen im europäischen Raum. Dennoch erregte es Verwunderung, wenn der Schreibende Bekannten darüber berichtete, daß dies ein Forschungsgegenstand sei. Wurde von Interviews mit Grand Prix-Fans erzählt, so fielen schnell Aussagen wie: „Wie kann man sich nur für so etwas Abseitiges und Triviales wie den Grand Prix interessieren“. Dennoch bin ich der Meinung, daß Fankulturen für die entstehende Mediengesellschaft ein nicht unwichtiges Forschungsthema darstellen. Zwar geht es nicht um eine medienpädagogische Fragestellung im engeren Sinne; die Fans des Grand Prix Eurovision sind dem Jugendalter längst entwachsen. Dennoch handelt es sich bei Fangemeinschaften um Phänomene, die im Rahmen von Jugend- und Kinderkulturen von besonderer Relevanz sind. So meint Winter (1997, daß jugendliche Fanwelten eine bedeutende Rolle als Kristallisationspunkte kultureller Differenzierung spielen: ,Die Zugehörigkeit zu einer Fan weit ist Teil der jugendlichen Lebensbewältigung in der Postmoderne, denn in der Gemeinschaft der Fans können Jugendliche emotionale Allianzen eingehen, außeralltäglichen Beschäftigungen nachgehen, expressive Identitätsmuster gemeinschaftlich realisieren und sich mit ihrer Lebenssituation als Heranwachsende auseinandersetzen“ (Winter 1997, S. 51f..

  9. Grand Canyon Monitoring and Research Center

    Hamill, John F.

    2009-01-01

    The Grand Canyon of the Colorado River, one of the world's most spectacular gorges, is a premier U.S. National Park and a World Heritage Site. The canyon supports a diverse array of distinctive plants and animals and contains cultural resources significant to the region's Native Americans. About 15 miles upstream of Grand Canyon National Park sits Glen Canyon Dam, completed in 1963, which created Lake Powell. The dam provides hydroelectric power for 200 wholesale customers in six western States, but it has also altered the Colorado River's flow, temperature, and sediment-carrying capacity. Over time this has resulted in beach erosion, invasion and expansion of nonnative species, and losses of native fish. Public concern about the effects of Glen Canyon Dam operations prompted the passage of the Grand Canyon Protection Act of 1992, which directs the Secretary of the Interior to operate the dam 'to protect, mitigate adverse impacts to, and improve values for which Grand Canyon National Park and Glen Canyon National Recreation Area were established...' This legislation also required the creation of a long-term monitoring and research program to provide information that could inform decisions related to dam operations and protection of downstream resources.

  10. Comprehensive District Reform: Philadelphia's Grand Experiment.

    Useem, Elizabeth; Balfanz, Robert

    2002-01-01

    This report describes "Philadelphia's Grand Experiment" in comprehensive school district reform, from its conception through its initial months of implementation. In 2001, as part of the remedy for low student performance, the governor ordered the state to take over governance of the Philadelphia School District, with a substantial…

  11. Rio Branco, grand strategy and naval power

    João Paulo Alsina Jr.

    2014-12-01

    Full Text Available This article addresses Baron of Rio Branco's grand strategy and the role played by the naval reorganization program (1904-1910 in this context. The ensuing case study determined the domestic and international constraints that affected the program, as well as the worldview of the patron of Brazilian diplomacy regarding military power's instrumentality to foreign policy.

  12. Reisipakkumine - Grand Tour Itaalias / Mai Levin

    Levin, Mai, 1942-

    2009-01-01

    Tiina Abeli koostatud ja Urmas Viigi kujundatud näitus "Grand Tour. Eesti kunstnikud Itaalias" Kumu Kunstimuuseumis 05. aprillini. Loetletud eksponeeritud tööde autoreid. Näitus annab ülevaate, kes siinsetest kunstnikest 19. sajandi algusest kuni 1930ndate aastateni Itaalias käisid ja kuidas see nende loomingut mõjutas

  13. Middle Rio Grande Basin Research Report 2008

    Deborah M. Finch; Catherine Dold

    2008-01-01

    An ecosystem is rarely static. A natural system composed of plants, animals, and microorganisms interacting with an area's physical factors, an ecosystem is always fluctuating and evolving. But sometimes, often at the hands of humans, ecosystems change too much. Such is the case with many of the ecosystems of the Middle Rio Grande Basin of New Mexico.

  14. Panel - Rio Grande restoration: Future directions

    Deborah M. Finch; Pete V. Domenici; Jeffrey. C. Whitney; Steve Harris; Brian Shields; Clifford S. Crawford

    1996-01-01

    The purpose of this panel was to discuss historical and current changes to the Rio Grande system, focusing on the middle Basin, and to present and review different individual, organizational, and political perspectives on the future of the system. Invitations were made to panelists based on their past and current interests and activities pertaining to restoration of...

  15. Improved Cloud Condensation Nucleus Spectrometer

    Leu, Ming-Taun

    2010-01-01

    An improved thermal-gradient cloud condensation nucleus spectrometer (CCNS) has been designed to provide several enhancements over prior thermal- gradient counters, including fast response and high-sensitivity detection covering a wide range of supersaturations. CCNSs are used in laboratory research on the relationships among aerosols, supersaturation of air, and the formation of clouds. The operational characteristics of prior counters are such that it takes long times to determine aerosol critical supersaturations. Hence, there is a need for a CCNS capable of rapid scanning through a wide range of supersaturations. The present improved CCNS satisfies this need. The improved thermal-gradient CCNS (see Figure 1) incorporates the following notable features: a) The main chamber is bounded on the top and bottom by parallel thick copper plates, which are joined by a thermally conductive vertical wall on one side and a thermally nonconductive wall on the opposite side. b) To establish a temperature gradient needed to establish a supersaturation gradient, water at two different regulated temperatures is pumped through tubes along the edges of the copper plates at the thermally-nonconductive-wall side. Figure 2 presents an example of temperature and supersaturation gradients for one combination of regulated temperatures at the thermally-nonconductive-wall edges of the copper plates. c) To enable measurement of the temperature gradient, ten thermocouples are cemented to the external surfaces of the copper plates (five on the top plate and five on the bottom plate), spaced at equal intervals along the width axis of the main chamber near the outlet end. d) Pieces of filter paper or cotton felt are cemented onto the interior surfaces of the copper plates and, prior to each experimental run, are saturated with water to establish a supersaturation field inside the main chamber. e) A flow of monodisperse aerosol and a dilution flow of humid air are introduced into the main

  16. The LASS [Larger Aperture Superconducting Solenoid] spectrometer

    Aston, D.; Awaji, N.; Barnett, B.

    1986-04-01

    LASS is the acronym for the Large Aperture Superconducting Solenoid spectrometer which is located in an rf-separated hadron beam at the Stanford Linear Accelerator Center. This spectrometer was constructed in order to perform high statistics studies of multiparticle final states produced in hadron reactions. Such reactions are frequently characterized by events having complicated topologies and/or relatively high particle multiplicity. Their detailed study requires a spectrometer which can provide good resolution in momentum and position over almost the entire solid angle subtended by the production point. In addition, good final state particle identification must be available so that separation of the many kinematically-overlapping final states can be achieved. Precise analyses of the individual reaction channels require high statistics, so that the spectrometer must be capable of high data-taking rates in order that such samples can be acquired in a reasonable running time. Finally, the spectrometer must be complemented by a sophisticated off-line analysis package which efficiently finds tracks, recognizes and fits event topologies and correctly associates the available particle identification information. This, together with complicated programs which perform specific analysis tasks such as partial wave analysis, requires a great deal of software effort allied to a very large computing capacity. This paper describes the construction and performance of the LASS spectrometer, which is an attempt to realize the features just discussed. The configuration of the spectrometer corresponds to the data-taking on K + and K - interactions in hydrogen at 11 GeV/c which took place in 1981 and 1982. This constitutes a major upgrade of the configuration used to acquire lower statistics data on 11 GeV/c K - p interactions during 1977 and 1978, which is also described briefly

  17. The LASS (Larger Aperture Superconducting Solenoid) spectrometer

    Aston, D.; Awaji, N.; Barnett, B.; Bienz, T.; Bierce, R.; Bird, F.; Bird, L.; Blockus, D.; Carnegie, R.K.; Chien, C.Y.

    1986-04-01

    LASS is the acronym for the Large Aperture Superconducting Solenoid spectrometer which is located in an rf-separated hadron beam at the Stanford Linear Accelerator Center. This spectrometer was constructed in order to perform high statistics studies of multiparticle final states produced in hadron reactions. Such reactions are frequently characterized by events having complicated topologies and/or relatively high particle multiplicity. Their detailed study requires a spectrometer which can provide good resolution in momentum and position over almost the entire solid angle subtended by the production point. In addition, good final state particle identification must be available so that separation of the many kinematically-overlapping final states can be achieved. Precise analyses of the individual reaction channels require high statistics, so that the spectrometer must be capable of high data-taking rates in order that such samples can be acquired in a reasonable running time. Finally, the spectrometer must be complemented by a sophisticated off-line analysis package which efficiently finds tracks, recognizes and fits event topologies and correctly associates the available particle identification information. This, together with complicated programs which perform specific analysis tasks such as partial wave analysis, requires a great deal of software effort allied to a very large computing capacity. This paper describes the construction and performance of the LASS spectrometer, which is an attempt to realize the features just discussed. The configuration of the spectrometer corresponds to the data-taking on K and K interactions in hydrogen at 11 GeV/c which took place in 1981 and 1982. This constitutes a major upgrade of the configuration used to acquire lower statistics data on 11 GeV/c K p interactions during 1977 and 1978, which is also described briefly.

  18. Cosmological implications of grand unified theories

    Nanopoulos, D.V.

    1982-01-01

    These lectures, mainly devoted to the cosmological implications of GUTs, also include the essential ingredients of GUTs and some of their important applications to particle physics. Section 1 contains some basic points concerning the structure of the standard strong and electroweak interactions prior to grand unification. A detailed expose of GUTs is attempted in sect. 2, including their basci principles and their consequences for particle physics. The minimal, simplest GUT, SU 5 is analysed in some detail and it will be used throughout these lectures as the GUT prototype. Finally, sect. 3 contains the most important cosmological implications of GUTs, including baryon number generation in the early Universe (in rather lengthy detail), dissipative processes in the very early Universe, grand unified monopoles, etc. (orig./HSI)

  19. The geology of Piz Pian Grand

    Huber, M.; Staeuble, J.

    1987-01-01

    Nagra has identified four potential sites for a repository for low- and intermediate-level waste. Exploration work is already underway at Oberbauenstock (UR) and Piz Pian Grand (GR). As part of the investigations in the Piz Pian Grand area, geological surface mapping was carried out between 1984 and 1987. Since the data obtained is still being evaluated, it would be premature to draw any interpretative conclusions at this stage. On the other hand, some of the most significant observations of this work can be summarised here. As a first step, the geological framework in which these investigations are to be seen should be defined. Observations will then be made on the rock content (lithology) and geometric structure (structural geology) of the area. (author) 6 figs

  20. Grand Gulf-prioritization of regulatory requirements

    Meisner, M.J.

    1993-01-01

    As cost pressures mount, Grand Gulf nuclear station (GGNS) is relying increasingly on various prioritization approaches to implement, modify, eliminate, or defer regulatory requirements. Regulatory requirements can be prioritized through the use of three measures: (1) safety (or risk) significance; (2) cost; and (3) public policy (or political) significance. This paper summarizes GGNS' efforts to implement solutions to regulatory issues using these three prioritization schemes to preserve a balance between cost and safety benefit

  1. Between two evils: Investors prefer grand corruption!

    Graf Lambsdorff, Johann

    2005-01-01

    Recent empirical studies claim that, in addition to levels of corruption, investors are deterred by its unpredictability. I claim instead that it is petty corruption that deters investors. I employ seven subcomponents of corruption for a sample of 102 countries that appear in the 2003 Global Competitiveness Report of the WEF. The second principal component of this data depicts a grand, political type, embracing corruption in government policymaking and in judicial decisions as opposed to corr...

  2. Grand Challenges in Music Information Research

    Goto, Masataka

    2012-01-01

    This paper discusses some grand challenges in which music information research will impact our daily lives and our society in the future. Here, some fundamental questions are how to provide the best music for each person, how to predict music trends, how to enrich human-music relationships, how to evolve new music, and how to address environmental, energy issues by using music technologies. Our goal is to increase both attractiveness and social impacts of music information research in the fut...

  3. Meliponiculture in Rio Grande do Norte

    Ulysses Madureira Maia

    2015-12-01

    Full Text Available ABSTRACT. Maia U.M., Jaffe R., Carvalho A.T. & Imperatriz-Fonseca V.L. [Meliponiculture in Rio Grande do Norte.] Meliponicultura no Rio Grande do Norte. Revista Brasileira de Medicina Veterinária, 37(4:327-333, 2015. Departamento de Biologia, Faculdade de Filosofia, Ciências e Letras de Ribeirão Preto, Universidade de São Paulo, Avenida Bandeirantes, 3900, Monte Alegre, Ribeirão Preto, SP 14040-901, Brasil. E-mail: ummaia@usp.br This study aimed to assess the current status of stingless bee beekeeping (meliponiculture in the State of Rio Grande do Norte, Brazil, with the aid of structured questionnaires made during visits to beekeepers. The results were compared with a previous census made in the state and with a similar study from Australia. Meliponiculture in Rio Grande do Norte is still informal and little standardized. The activity has grown in recent years considering the mean number of nests per beekeeper. Most apiaries are formed of up to 50 colonies, usually distributed in the backyards of homes. Twelve species of stingless bees were reared in the state, and the most common was the “Jandaíra” bee (Melipona subnitida, whose honey is considered medicinal. While many beekeepers already know the importance of bees as pollinators, stingless bees are still not used for crop pollination. Compared to a recent analysis of beekeeping in Australia, meliponiculture in Brazil is more traditional, honey is the main product and the number of colonies per beekeeper is much higher. Our results highlight the need to reinforce knowledge about bees and promote specific training aimed at improving and standardizing management practices.

  4. Neutrino mixing in a grand unified theory

    Milton, K.; Tanaka, K.

    1980-01-01

    Neutrino mixing in a grand unified theory in which the neutrino mass matrix is determined by the Gell-Mann-Ramond-Slansky mechanism was investigated. With an arbitrary real right-handed Majorana mass matrix which incorporates three neutrino mass scales, the effects of the up-quark mass matrix are found to be dominant and as a result no significant mixing of ν/sub e/ occurs, while ν/sub μ/ - ν/sub γ/ mixing can be substantial

  5. The Grand Strategy of Charles de Gaulle

    1989-09-08

    4. TITLE AND SUBTITLE The Grand Startegy of Charles de Gaulle 5a. CONTRACT NUMBER 5b. GRANT NUMBER 5c. PROGRAM ELEMENT NUMBER 6. AUTHOR(S...dependent on French influence within NATO and the Common Market . De Gaulle frequently used these fora to veto British and American initiatives. As Cook...the reserve currency. Gold would be the basis of international finance and a French-dominated European Common Market would provide the framework

  6. Adaptive Tunable Laser Spectrometer for Space Applications

    Flesch, Gregory; Keymeulen, Didier

    2010-01-01

    An architecture and process for the rapid prototyping and subsequent development of an adaptive tunable laser absorption spectrometer (TLS) are described. Our digital hardware/firmware/software platform is both reconfigurable at design time as well as autonomously adaptive in real-time for both post-integration and post-launch situations. The design expands the range of viable target environments and enhances tunable laser spectrometer performance in extreme and even unpredictable environments. Through rapid prototyping with a commercial RTOS/FPGA platform, we have implemented a fully operational tunable laser spectrometer (using a highly sensitive second harmonic technique). With this prototype, we have demonstrated autonomous real-time adaptivity in the lab with simulated extreme environments.

  7. A compact multichannel spectrometer for Thomson scattering

    Schoenbeck, N. L.; Schlossberg, D. J.; Dowd, A. S.; Fonck, R. J.; Winz, G. R. [Department of Engineering Physics, University of Wisconsin, Madison, Wisconsin 53706 (United States)

    2012-10-15

    The availability of high-efficiency volume phase holographic (VPH) gratings and intensified CCD (ICCD) cameras have motivated a simplified, compact spectrometer for Thomson scattering detection. Measurements of T{sub e} < 100 eV are achieved by a 2971 l/mm VPH grating and measurements T{sub e} > 100 eV by a 2072 l/mm VPH grating. The spectrometer uses a fast-gated ({approx}2 ns) ICCD camera for detection. A Gen III image intensifier provides {approx}45% quantum efficiency in the visible region. The total read noise of the image is reduced by on-chip binning of the CCD to match the 8 spatial channels and the 10 spectral bins on the camera. Three spectrometers provide a minimum of 12 spatial channels and 12 channels for background subtraction.

  8. Multichannel Dynamic Fourier-Transform IR Spectrometer

    Balashov, A. A.; Vaguine, V. A.; Golyak, Il. S.; Morozov, A. N.; Khorokhorin, A. I.

    2017-09-01

    A design of a multichannel continuous scan Fourier-transform IR spectrometer for simultaneous recording and analysis of the spectral characteristics of several objects is proposed. For implementing the design, a multi-probe fiber is used, constructed from several optical fibers connected into a single optical connector and attached at the output of the interferometer. The Fourier-transform spectrometer is used as a signal modulator. Each fiber is individually mated with an investigated sample and a dedicated radiation detector. For the developed system, the radiation intensity of the spectrometer is calculated from the condition of the minimum spectral resolution and parameters of the optical fibers. Using the proposed design, emission spectra of a gas-discharge neon lamp have been recorded using a single fiber 1 mm in diameter with a numerical aperture NA = 0.22.

  9. Partial pressure measurements with an active spectrometer

    Brooks, N.H.; Jensen, T.H.; Colchin, R.J.; Maingi, R.; Wade, M.R.; Finkenthal, D.F.; Naumenko, N.; Tugarinov, S.

    1998-07-01

    Partial pressure neutral ga measurements have been made using a commercial Penning gauge in conjunction with an active spectrometer. In prior work utilizing bandpass filters and conventional spectrometers, trace concentrations of the hydrogen isotopes H, D, T and of the noble gases He, Ne and Ar were determined from characteristic spectral lines in the light emitted by the neutral species of these elements. For all the elements mentioned, the sensitivity was limited by spectral contamination from a pervasive background of molecular hydrogen radiation. The active spectrometer overcomes this limitations by means of a digital lock-in method and correlation with reference spectra. Preliminary measurements of an admixture containing a trace amount of neon in deuterium show better than a factor of 20 improvement in sensitivity over conventional techniques. This can be further improved by correlating the relative intensities of multiple lines to sets of reference spectra

  10. Gas-dust-impact mass spectrometer

    Semkin, N D; Myasnikov, S V; Pomelnikov, R A

    2002-01-01

    Paper describes design of a mass spectrometer to study element composition of micro meteorite and man-made particles in space. Paper describes a way to improve resolution of mass spectrometer based on variation of parameters of accelerating electric field in time. The advantage of the given design of mass spectrometer in comparison with similar ones is its large operating area and higher resolution at the comparable weight and dimensions. Application of a combined design both for particles and for gas enables to remove space vehicle degassing products from the spectrum and, thus, to improve reliability of the acquired information, as well as, to acquire information on a gas component of the external atmosphere of a space vehicle

  11. Miniature neutron-alpha activation spectrometer

    Rhodes, Edgar; Goldsten, John; Holloway, James Paul; He, Zhong

    2002-01-01

    We are developing a miniature neutron-alpha activation spectrometer for in-situ analysis of chem-bio samples, including rocks, fines, ices, and drill cores, suitable for a lander or Rover platform for Mars or outer-planet missions. In the neutron-activation mode, penetrating analysis will be performed of the whole sample using a γ spectrometer and in the α-activation mode, the sample surface will be analyzed using Rutherford-backscatter and x-ray spectrometers. Novel in our approach is the development of a switchable radioactive neutron source and a small high-resolution γ detector. The detectors and electronics will benefit from remote unattended operation capabilities resulting from our NEAR XGRS heritage and recent development of a Ge γ detector for MESSENGER. Much of the technology used in this instrument can be adapted to portable or unattended terrestrial applications for detection of explosives, chemical toxins, nuclear weapons, and contraband

  12. A compact multichannel spectrometer for Thomson scatteringa)

    Schoenbeck, N. L.; Schlossberg, D. J.; Dowd, A. S.; Fonck, R. J.; Winz, G. R.

    2012-10-01

    The availability of high-efficiency volume phase holographic (VPH) gratings and intensified CCD (ICCD) cameras have motivated a simplified, compact spectrometer for Thomson scattering detection. Measurements of Te VPH grating and measurements Te > 100 eV by a 2072 l/mm VPH grating. The spectrometer uses a fast-gated (˜2 ns) ICCD camera for detection. A Gen III image intensifier provides ˜45% quantum efficiency in the visible region. The total read noise of the image is reduced by on-chip binning of the CCD to match the 8 spatial channels and the 10 spectral bins on the camera. Three spectrometers provide a minimum of 12 spatial channels and 12 channels for background subtraction.

  13. A compact multichannel spectrometer for Thomson scattering

    Schoenbeck, N. L.; Schlossberg, D. J.; Dowd, A. S.; Fonck, R. J.; Winz, G. R.

    2012-01-01

    The availability of high-efficiency volume phase holographic (VPH) gratings and intensified CCD (ICCD) cameras have motivated a simplified, compact spectrometer for Thomson scattering detection. Measurements of T e e > 100 eV by a 2072 l/mm VPH grating. The spectrometer uses a fast-gated (∼2 ns) ICCD camera for detection. A Gen III image intensifier provides ∼45% quantum efficiency in the visible region. The total read noise of the image is reduced by on-chip binning of the CCD to match the 8 spatial channels and the 10 spectral bins on the camera. Three spectrometers provide a minimum of 12 spatial channels and 12 channels for background subtraction.

  14. A compact multichannel spectrometer for Thomson scattering.

    Schoenbeck, N L; Schlossberg, D J; Dowd, A S; Fonck, R J; Winz, G R

    2012-10-01

    The availability of high-efficiency volume phase holographic (VPH) gratings and intensified CCD (ICCD) cameras have motivated a simplified, compact spectrometer for Thomson scattering detection. Measurements of T(e) VPH grating and measurements T(e) > 100 eV by a 2072 l∕mm VPH grating. The spectrometer uses a fast-gated (~2 ns) ICCD camera for detection. A Gen III image intensifier provides ~45% quantum efficiency in the visible region. The total read noise of the image is reduced by on-chip binning of the CCD to match the 8 spatial channels and the 10 spectral bins on the camera. Three spectrometers provide a minimum of 12 spatial channels and 12 channels for background subtraction.

  15. [Grand Banks activity : updates and opportunities

    Bruce, G.

    1998-01-01

    An overview of the exploration and on-going activities by the petroleum industry on the Grand Banks of Newfoundland was presented. The two offshore oil developments underway are Hibernia and Terra Nova, both located in the Jeanne d'Arc Basin. Current production from Hibernia is 68,000 bopd, expected to rise to 130,000 bopd in 1999. The Terra Nova Field is still under development. Total recoverable reserves from the 17 discoveries made in the Jeanne d'Arc Basin are estimated at 1.6 billion barrels of oil and 4 trillion cubic feet of gas. Industry participants in the area include Amoco, Petro-Canada, Mobil, Chevron, Husky and Norsk Hydro. Petro-Canada believes the Grand Banks represent one of the best opportunities for oil anywhere in the world. There are currently 21 exploration licenses held on the Grand Banks. Major attractions of the area include the large reserve potential, the relatively low finding costs, the size of the pools being discovered, improvements in offshore technology that have substantially lowered development costs, and a profit-sensitive generic royalty regime that ensures reasonable rates of return for investors. figs

  16. Proton decay in grand unified theories

    Lucha, W.

    1984-01-01

    Interactions which violate the conservation of baryon and lepton number represent an intrinsic part of all grand unified theories (GUTs) of strong and electroweak interactions. These new interactions - predicted within the framework of GUTs - generate B and L violating four-fermion interactions via the exchange of superheavy particles which cannot be ascribed a well-defined baryon or lepton number. The effective coupling constant of these four-fermion interactions might be large enough to make the proton decay detectable by the present generation of experiments. In this review the basic concepts of conventional as well as supersymmetric GUTs relevant for proton decay are sketched. The baryon number violating sector of grand unified theories is discussed in more detail. Special emphasis is laid on the various selection rules arising as consequences of low-energy gauge invariance and supersymmetry for proton decay. These selection rules already determine the coarse pattern of the resulting decay modes and branching ratios without any reference to or detailed knowledge of the underlying grand unified theory. Finally the numerous theoretical predictions are summarized and confronted with experiment. (Author)

  17. Raptor Use of the Rio Grande Gorge

    Ponton, David A. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2015-03-20

    The Rio Grande Gorge is a 115 km long river canyon located in Southern Colorado (15 km) and Northern New Mexico (100 km). The majority of the canyon is under the administration of the Bureau of Land Management {BLM), and 77 km of the canyon south of the Colorado/New Mexico border are designated Wild River under the National Wild and Scenic Rivers Act of 1968. Visits I have made to the Rio Grande Gorge over the past 15 .years disclosed some raptor utilization. As the Snake River Birds of Prey Natural Area gained publicity, its similarity to the Rio Grande Gorge became obvious, and I was intrigued by the possibility of a high raptor nesting density in the Gorge. A survey in 1979 of 20 km of the northern end of the canyon revealed a moderately high density of red-tailed hawks and prairie falcons. With the encouragement of that partial survey, and a need to assess the impact of river-running on nesting birds of prey, I made a more comprehensive survey in 1980. The results of my surveys, along with those of a 1978 helicopter survey by the BLM, are presented in this report, as well as general characterization of the area, winter use by raptors, and an assessment of factors influencing the raptor population.

  18. Indigenously built resonance ionization mass spectrometer

    Razvi, M.A.N.; Jayasekharan, T.; Thankarajan, K.; Guhagarkar, M.B.; Dixit, M.N.; Bhale, G.L.

    2000-04-01

    Design, fabrication and performance testing of an indigenously built Resonance Ionization Mass Spectrometer (RIMS) is presented in this report. The instrument is totally indigenous, but for the laser components consisting of the excimer laser and tunable dye lasers. Constructional details of atomic beam source and linear time-of-flight mass spectrometer are included. Finally, commissioning and performance testing of the instrument is described. Mass resolving power of 400 and a detection limit of 100 atoms has been achieved using this RIMS set-up. (author)

  19. Upgrade of an old Raman Spectrometer

    Hansen, Susanne Brunsgaard; Berg, Rolf W.; Stenby, Erling Halfdan

    2004-01-01

    Improvement of a conventional Jeol Raman spectrometer with a single channel photo multiplier detector is described. New optical components (fibres, mirror, lens and CCD detector) have been chosen to design a high quality and easy-to-use instrument. Tests have shown that with this modified...... spectrometer Raman spectra can be acquired of a quality comparable to the spectra obtained previously, but the time needed to obtain a spectrum is markedly reduced. Selected test spectra and a simple calibration procedure to obtain the wavenumber values from the band CCD pixel position are presented....

  20. A proposed neutron spectrometer system for JET

    Elevant, T.; Hellbom, G.; Scheffel, J.; Malmskog, S.

    1979-12-01

    A neutron spectrometer system is proposed primarily for measurements of ion temperature and density and ion beam energy distribution in extended fusion plasmas like e.g. in JET. Three different spectrometers are involved: time of flight, proton recoil and 3 He. Energy resolutions of a few percent both for DD and DT neutrons are provided. Six order of magnitudes in flux ranges will be covered by the system when employing multi-target systems. A neutron collimator and shielding system will be desirable in order to obtain relevant information. Due to the entire differences in energy and fluxes for DD and DT plasmas a flexible collimator-shielding system is recommended

  1. Beam analysis spectrometer for relativistic heavy ions

    Schimmerling, W.; Subramanian, T.S.; McDonald, W.J.; Kaplan, S.N.; Sadoff, A.; Gabor, G.

    1983-01-01

    A versatile spectrometer useful for measuring the mass, charge, energy, fluence and angular distribution of primaries and fragments associated with relativistic heavy ion beams is described. The apparatus is designed to provide accurate physical data for biology experiments and medical therapy planning as a function of depth in tissue. The spectrometer can also be used to measure W, the average energy to produce an ion pair, range-energy, dE/dx, and removal cross section data of interest in nuclear physics. (orig.)

  2. Electron-ion-x-ray spectrometer system

    Southworth, S.H.; Deslattes, R.D.; MacDonald, M.A.

    1993-01-01

    The authors describe a spectrometer system developed for electron, ion, and x-ray spectroscopy of gas-phase atoms and molecules following inner-shell excitation by tunable synchrotron radiation. The spectrometer has been used on beamline X-24A at the National Synchrotron Light Source for excitation-dependent studies of Ar L-shell and K-shell photoexcitation and vacancy decay processes. The instrumentation and experimental methods are discussed, and examples are given of electron spectra and coincidence spectra between electrons and fluorescent x-rays

  3. Single spectrometer station for neutrino-tagging

    Nedyalkov, I.P.

    1984-01-01

    A neutrino tagging station built with respect to the following scheme is proposed. A beam of muons and kaons passes through a magnetic spectrometer, where the energy of each particle is measured. There are coordinate detectors behind the spectrometer in several planes, where the direction of the trajectory of a given particle is determined. Thus, mesons enter the decay point wth the known 4-momentum. Behind the decay point the direction of μ-meson generated by the decay of parent mesons is measured. It is shown that information is sufficient for determining the kind of parent particle (pion or kaon), the energy and the direction of trajectory of the neutrino

  4. Spectrometer Baseline Control Via Spatial Filtering

    Burleigh, M. R.; Richey, C. R.; Rinehart, S. A.; Quijada, M. A.; Wollack, E. J.

    2016-01-01

    An absorptive half-moon aperture mask is experimentally explored as a broad-bandwidth means of eliminating spurious spectral features arising from reprocessed radiation in an infrared Fourier transform spectrometer. In the presence of the spatial filter, an order of magnitude improvement in the fidelity of the spectrometer baseline is observed. The method is readily accommodated within the context of commonly employed instrument configurations and leads to a factor of two reduction in optical throughput. A detailed discussion of the underlying mechanism and limitations of the method are provided.

  5. Ion transmission in a linear radiofrequency spectrometer

    Gomet, J.-C.

    1975-01-01

    A linear radiofrequency spectrometer is used for the purpose of experimental determination of the absolute ionization cross sections of various ions obtained by electron impact on polyatomic molecules. The transmission of the apparatus is studied: it does not only depend on the mass resolution of the spectrometer, but also on the nature of ions. It is affected by charge transfers, especially for the parent ions. An empiric way of correction of the apparatus function is given which allows the use at 10 -6 Torr [fr

  6. Noise considerations in millimeter-wave spectrometers

    Zoellner, W.D.; Kolbe, W.F.; Leskovar, B.

    1978-12-01

    An improved version of a microwave spectrometer operating in the vicinity of 70 GHz is described. The spectrometer, which incorporates a Fabry-Perot resonator and superheterodyne detection for high sensitivity is designed for the detection of gaseous pollutants and other atmospheric constituents. The instrument is capable of detecting polar molecules with absorption coefficients as small as 2 x 10 -9 cm -1 . For sulphur dioxide diluted in air, this sensitivity corresponds to a detection limit of 1.2 ppm without preconcentration and with a time constant of 1 second. Measurements and analysis of the noise contributions limiting the sentivity are presented

  7. A driving system for Moessbauer spectrometer

    Maslan, M.; Cholmeckij, A.; Evdokimov, V.; Misevic, O.; Fedorov, A.; Zak, D.

    1993-01-01

    The driving system of a Moessbauer spectrometer is described. The system comprises a minivibrator, a digital generator of the reference velocity signal, and circuits for controlling the vibrator. The reference velocity signal is stored by the control computer in an intermediate storage. The feedback in the control circuits includes correction for nonlinearity of the driving facility. A Moessbauer spectrometer which is equipped with this driving system exhibits a velocity scale nonlinearity below 0.1%. The resonance line width for sodium nitroprusside is 0.27 ± 0.01 mm/s. (author). 6 figs., 8 refs

  8. Large acceptance spectrometers for π0 mesons

    Awes, T.C.; Ferguson, R.L.; Obenshain, F.E.

    1984-01-01

    A spectrometer composed of lead-oxide loaded glass blocks has been constructed for detection of neutral pi mesons emitted in low energy heavy ion reactions. The spectrometer detects the Cerenkov radiation emitted when the high energy photons (Eγ approx. 70 MeV) resulting from π 0 decay create electron-position pairs in the glass, initiating electromagnetic showers. A geometric acceptance of better than 5% of 4π is possible; the π 0 detection efficiency varies between this value at T/sub π/ = 0 MeV and 1% for T/sub π/ approx. 100 MeV

  9. Streaked, x-ray-transmission-grating spectrometer

    Ceglio, N.M.; Roth, M.; Hawryluk, A.M.

    1981-08-01

    A free standing x-ray transmission grating has been coupled with a soft x-ray streak camera to produce a time resolved x-ray spectrometer. The instrument has a temporal resolution of approx. 20 psec, is capable of covering a broad spectral range, 2 to 120 A, has high sensitivity, and is simple to use requiring no complex alignment procedure. In recent laser fusion experiments the spectrometer successfully recorded time resolved spectra over the range 10 to 120 A with a spectral resolving power, lambda/Δlambda of 4 to 50, limited primarily by source size and collimation effects

  10. Triple-axis spectrometer DruechaL

    Buehrer, W.; Keller, P.

    1996-01-01

    DruechaL is a triple-axis spectrometer located at a cold guide. The characteristics of guide and instrument allow the use of a broad spectral range of neutrons. The resolution in momentum and energy transfer can be tuned to match the experimental requirements by using either collimators or focusing systems (monochromator, antitrumpet, analyser). (author) figs., tabs., refs

  11. Neutron spectrometer using NE218 liquid scintillator

    Dance, J.B.; Francois, P.E.

    1976-01-01

    A neutron spectrometer has been constructed using NE218 liquid scintillator. Discrimination against electron-gamma events was obtained usng a charge-comparison pulse shape discrimination system. The resolution obtained was about 0.25 MeV F.W.H.M. at 2.0 MeV

  12. A 4-PI DILEPTON SPECTROMETER - PEPSI

    BUDA, A; BACELAR, JCS; BALANDA, A; VANKLINKEN, J; SUJKOWSKI, Z; VANDERWOUDE, A

    1993-01-01

    A novel positron-electron pair spectroscopy instrument (PEPSI) was designed to measure transitions in the energy region 10-40 MeV. It consists of Nd2Fe14B permanent magnets forming a compact 4 pi magnetic filter consisting of 12 positron and 20 electron mini-orange-like spectrometers. The response

  13. Calculational approach to ionization spectrometer design

    Gabriel, T.A.

    1974-01-01

    Many factors contribute to the design and overall performance of an ionization spectrometer. These factors include the conditions under which the spectrometer is to be used, the required performance, the development of the hadronic and electromagnetic cascades, leakage and binding energies, saturation effects of densely ionizing particles, nonuniform light collection, sampling fluctuations, etc. The calculational procedures developed at Oak Ridge National Laboratory that have been applied to many spectrometer designs and that include many of the influencing factors in spectrometer design are discussed. The incident-particle types which can be considered with some generality are protons, neutrons, pions, muons, electrons, positrons, and gamma rays. Charged kaons can also be considered but with less generality. The incident-particle energy range can extend into the hundreds of GeV range. The calculations have been verified by comparison with experimental data but only up to approximately 30 GeV. Some comparisons with experimental data are also discussed and presented so that the flexibility of the calculational methods can be demonstrated. (U.S.)

  14. A 'tiny-orange' spectrometer for electrons

    Silva, N.C. da.

    1990-01-01

    An tiny-orange electron spectrometer was designed and constructed using flat permanent magnets and a surface barrier detector. The transmission functions of different system configurations were determined for energies in the 200-1100 KeV range. A mathematical model for the system was developed. (L.C.J.A.)

  15. Triple-axis spectrometer DruechaL

    Buehrer, W; Keller, P [Lab. for Neutron Scattering ETH Zurich, Zurich (Switzerland) and Paul Scherrer Institute, Villigen (Switzerland)

    1996-11-01

    DruechaL is a triple-axis spectrometer located at a cold guide. The characteristics of guide and instrument allow the use of a broad spectral range of neutrons. The resolution in momentum and energy transfer can be tuned to match the experimental requirements by using either collimators or focusing systems (monochromator, antitrumpet, analyser). (author) figs., tabs., refs.

  16. COMPASS course to future computing [CERN spectrometer

    CERN. Geneva

    1999-01-01

    A major new spectrometer that is being installed at CERN will be a flagship fixed-target experiment for the millennium. Its voracious appetite for data requires new computing solutions, opening the door for subsequent 2lst-century studies. (0 refs).

  17. Calibration method for ion mobility spectrometer

    Vasiliev, Valery

    2011-01-01

    The new method for the calibration of the ion mobility spectrometer has been developed. This article describes the working principle, advantages and disadvantages of the calibration method operating in the mode of explosives detection. This method is most suitable for use in portable detectors, due to the small weight, small size parameters and low power consumption.

  18. A superheterodyne spectrometer for electronic paramagnetic. Resonance

    Laffon, J.L.

    1963-12-01

    After a few generalities about electron paramagnetic resonance, a consideration of different experimental techniques authorises the choice of a particular type of apparatus. An EPR superheterodyne spectrometer built in the laboratory and having a novel circuit is described in detail. With this apparatus, many experimental results have been obtained and some of these are described as example. (author) [fr

  19. LEP constraints on grand unified theories

    Sarkar, Utpal

    1993-01-01

    Recent developments on grand unified theories (GUTs) in the context of the LEP measurements of the coupling constants are reviewed. The three coupling constants at the electroweak scale have been measured at LEP quite precisely. One can allow these couplings to evolve with energy following the renormalization group equations for the various groups and find out whether all the coupling constants meet at any energy. It was pointed out that the minimal SU(5) grand unified theory fails to satisfy this test. However, various extensions of the theory are still allowed. These extensions include (i) supersymmetric SU(5) GUT, with some arbitrariness in the susy breaking scale arising from the threshold corrections, (ii) non-susy SU(5) GUTs with additional fermions as well as Higgs multiplets, which has masses of the order of TeV, and (iii) non-renormalizable effect of gravity with a fine tuned relation among the coupling constants at the unification energy. The LEP results also constrain GUTs with an intermediate symmetry breaking scale. By adjusting the intermediate symmetry breaking scale, one usually can have unification, but these theories get constrained. For example, the left-right symmetric theories coming from GUTs can be broken only at energies higher than about ∼10 10 GeV. This implies that if right handed gauge bosons are found at energies lower than this scale, then that will rule out the possibility of grand unification. Another recent interesting development on the subject, namely, low energy unification, is discussed in this context. All the coupling constants are unified at energies of the order of ∼10 8 GeV when they are embedded in an SU(15)GUT, with some particular symmetry breaking pattern. But even in this case the results of the intermediate symmetry breaking scale remain unchanged. (author). 16 refs., 3 figs

  20. Maternal and fetal outcome in grand multipara

    Qamar, A.; Qamar, S.

    2015-01-01

    Study Design: Case control study. Place and Duration of Study: Gynecology and Obstetric Unit-I of the Jinnah Post Graduate and Medical Centre Karachi, from February 2009 to January 2010. Patients and Methods: One hundred (100) patients of grand multipara (GMP), (parity = 5) and 100 patients of multipara (MP) (parity 2-4) were included in the study. Pregnant women with known medical conditions including essential hypertension, diabetes mellitus, epilepsy, primigravidas, women with previous caesarean section and twin pregnancies were excluded. Patients were admitted through antenatal clinic and emergency. A detailed history was taken and a physical examination was done with special emphasis on obstetrical examination. Investigations like blood CP, Urine D/R, blood grouping and sonogram were done. During labour, mother and neonates were managed according to ward protocols. Maternal and fetal outcomes were compared among GMPs and MPs. Results: A high frequency of anaemia (81% vs 20%), pregnancy induced hypertension (45%, vs. 26%) and gestational diabetes (9%, vs1%) were seen in GMP as compared to MP group. Frequency of malpresentations (26% vs 15%), postpartum hemorrhage (15%, vs 10%) and intrauterine deaths (26%, vs 13%) were higher in GMP group along with a high caesarean delivery rate (GMP 21%, MP 14%). A higher maternal mortality (GMP 4%, MP 1%) and low APGAR score (GMP 12%, MP 4%) were observed among babies born to grand multipara group. Conclusion: Grand multiparity is associated with adverse outcome for both mother and fetus. Effort should be directed to reduce high parity in the community through effective family planning initiatives. Specialized antenatal and obstetrical care facilities should be available. (author)

  1. Lie groups and grand unified theories

    Gubitoso, M.D.

    1987-01-01

    This work presents some concepts in group theory and Lie algebras and, at same time, shows a method to study and work with semisimple Lie groups, based on Dynkin diagrams. The aproach taken is not completely formal, but it presents the main points of the elaboration of the method, so its mathematical basis is designed with the purpose of making the reading not so cumbersome to those who are interested only in a general picture of the method and its usefulness. At the end it is shown a brief review of gauge theories and two grand-unification models based on SO(13) and E 7 gauge groups. (author) [pt

  2. Grand Canonical Ensembles in General Relativity

    Klein, David; Yang, Wei-Shih

    2012-01-01

    We develop a formalism for general relativistic, grand canonical ensembles in space-times with timelike Killing fields. Using that, we derive ideal gas laws, and show how they depend on the geometry of the particular space-times. A systematic method for calculating Newtonian limits is given for a class of these space-times, which is illustrated for Kerr space-time. In addition, we prove uniqueness of the infinite volume Gibbs measure, and absence of phase transitions for a class of interaction potentials in anti-de Sitter space.

  3. Produccion de plantas grandes usando minicontenedores

    R. Kasten Dumroese; Thomas D. Landis

    2012-01-01

    En América del Norte hay cada vez más interés por la producción híbrida o mixta. La misma consiste en cultivar plantines en contenedores de pequeño volumen y luego trasplantarlos; el trasplante se puede realizar a canteros en el suelo como en la producción a raíz desnuda o bien a contenedores más grandes. Originalmente se llamaban plantines "plug+", "...

  4. Portable spectrometer monitors inert gas shield in welding process

    Grove, E. L.

    1967-01-01

    Portable spectrometer using photosensitive readouts, monitors the amount of oxygen and hydrogen in the inert gas shield of a tungsten-inert gas welding process. A fiber optic bundle transmits the light from the welding arc to the spectrometer.

  5. Habitat Mapping and Classification of the Grand Bay National Estuarine Research Reserve using AISA Hyperspectral Imagery

    Rose, K.

    2012-12-01

    Habitat mapping and classification provides essential information for land use planning and ecosystem research, monitoring and management. At the Grand Bay National Estuarine Research Reserve (GRDNERR), Mississippi, habitat characterization of the Grand Bay watershed will also be used to develop a decision-support tool for the NERR's managers and state and local partners. Grand Bay NERR habitat units were identified using a combination of remotely sensed imagery, aerial photography and elevation data. Airborne Imaging Spectrometer for Applications (AISA) hyperspectral data, acquired 5 and 6 May 2010, was analyzed and classified using ENVI v4.8 and v5.0 software. The AISA system was configured to return 63 bands of digital imagery data with a spectral range of 400 to 970 nm (VNIR), spectral resolution (bandwidth) at 8.76 nm, and 1 m spatial resolution. Minimum Noise Fraction (MNF) and Inverse Minimum Noise Fraction were applied to the data prior to using Spectral Angle Mapper ([SAM] supervised) and ISODATA (unsupervised) classification techniques. The resulting class image was exported to ArcGIS 10.0 and visually inspected and compared with the original imagery as well as auxiliary datasets to assist in the attribution of habitat characteristics to the spectral classes, including: National Agricultural Imagery Program (NAIP) aerial photography, Jackson County, MS, 2010; USFWS National Wetlands Inventory, 2007; an existing GRDNERR habitat map (2004), SAV (2009) and salt panne (2002-2003) GIS produced by GRDNERR; and USACE lidar topo-bathymetry, 2005. A field survey to validate the map's accuracy will take place during the 2012 summer season. ENVI's Random Sample generator was used to generate GIS points for a ground-truth survey. The broad range of coastal estuarine habitats and geomorphological features- many of which are transitional and vulnerable to environmental stressors- that have been identified within the GRDNERR point to the value of the Reserve for

  6. The TRIUMF low energy pion spectrometer and channel

    Sobie, R.J.; Drake, T.E.; Barnett, B.M.; Erdman, K.L.; Gyles, W.; Johnson, R.R.; Roser, H.W.; Tacik, R.; Blackmore, E.W.; Gill, D.R.

    1983-08-01

    A low energy pion spectrometer has been developed for use with the TRIUMF M13 pion channel. The combined channel and spectrometer resolution is presently 1.1 MeV at T = 50 MeV. This is limited by the amount of gas and detector material in the spectrometer in addition to the inherent resolution of the channel. Improvements to both the spectrometer and channel are discussed

  7. The portable micro-computerized multichannel spectrometer for geological application

    Fang Fang; Jia Wenyi; Zou Rongsheng; Ma Yingjie; Zhou Jianbin

    1999-01-01

    The portable micro-computerized multichannel spectrometer is based on the book computer and employs the A/D integrated circuit with 12 bits. It is a 2048 channel spectrometer which is consisted of hardware and software. The author analyzed the hardware circuit and software construction of the micro-computerized multichannel spectrometer which is suitable for filed geological application. The main technical specifications and application of the new multichannel spectrometer were also discussed

  8. The portable micro-computerized multichannel spectrometer for geological application

    Fang Fang; Jia Wenyi; Zhou Rongsheng; Ma Yingjie; Zhou Jianbin

    1999-01-01

    The portable micro-computerized multichannel spectrometer is based on the book computer and employs the A/D integrated circuit with 12 bits. It is a 2048 channel spectrometer which consists of hardware and software. The author analyzed the hardware circuit and software construction of the micro-computerized multichannel spectrometer which is suitable for field geological application. The main technical specifications and application of the new multichannel spectrometer were also discussed

  9. High resolution solar soft X-ray spectrometer

    Zhang Fei; Wang Huanyu; Peng Wenxi; Liang Xiaohua; Zhang Chunlei; Cao Xuelei; Jiang Weichun; Zhang Jiayu; Cui Xingzhu

    2012-01-01

    A high resolution solar soft X-ray spectrometer (SOX) payload onboard a satellite is developed. A silicon drift detector (SDD) is adopted as the detector of the SOX spectrometer. The spectrometer consists of the detectors and their readout electronics, a data acquisition unit and a payload data handling unit. A ground test system is also developed to test SOX. The test results show that the design goals of the spectrometer system have been achieved. (authors)

  10. RADIO-FREQUENCY MASS SPECTROMETERS AND THEIR APPLICATIONS IN SPACE

    Gilmour, Jr., A. S.

    1963-08-15

    The operation of three common radio-frequency mass spectrometers is described, and their performances are compared. Their limitations are pointed out. It is concluded that the quadrupole spectrometer has fewer limitations and is more generally useful in space probes than the other devices. Some present and proposed uses of spectrometers in space are discussed, and the problem of contamination of the atmosphere being sampled by the spectrometer is reviewed. (auth)

  11. The Grand Duchy on the Grand Tour: A Historical Study of Student Migration in Luxembourg

    Rohstock, Anne; Schreiber, Catherina

    2013-01-01

    Since Luxembourg became independent in 1839, practically the entire political, economic and intellectual elite of the country has been socialised abroad. It was only in 2003 that the Grand Duchy set up its own university; before then, young Luxembourgers had to study in foreign countries. Over the past 150 years, Luxembourg has thus experienced…

  12. 28 milliards d’euros, c’est grand comment ?

    Ozer, Pierre; Salmon, Marc; Theunissen, Yannick

    2009-01-01

    J’ouvre mon quotidien. Fortis : 28 milliards d’euros de pertes en 2008. Ma fille de sept ans qui commence à lire et pose sans cesse des questions sur tout me lance : « Dis-moi, papa : 28 milliards d’euros, c’est grand comment ? ». Grande question… Je réfléchis et tente de trouver une parade parlante pour un enfant qui, in fine, se pose les mêmes questions que les grandes personnes.

  13. Gamma ray and neutrino detector facility (GRANDE), Task C

    Sobel, H.W.; Yodh, G.B.

    1991-08-01

    GRANDE is an imaging, water Cerenkov detector, which combines in one facility an extensive air shower array and a high-energy neutrino detector. We proposed that the detector be constructed in phases, beginning with an active detector area of 31,000 m 2 (GRANDE-I) 2 and expanding to a final size of 100,000--150,00 m 2 . Some of the characteristics of GRANDE-I are discussed in this paper

  14. A magnetic-lens - mini-orange coincidence spectrometer

    Bargholtz, C.; Holmberg, L.; Ruus, N.; Tegner, P.E.; Weiss, G.

    1997-04-01

    A coincidence spectrometer consisting of a Gerholm type magnetic lens and a permanent magnet mini-orange spectrometer is described. Electron-electron or electron-positron coincidences may be registered in various angular settings. The spectrometer has been developed mainly to search for anomalous contributions to Bhabha scattering or positrons and is at present used for such studies. 6 refs

  15. Spectrometer for neutron inelastic scattering investigations of microsamples

    Balagurov, A.M.; Kozlenko, D.P.; Platonov, S.L.; Savenko, B.N.; Glazkov, V.P.; Krasnikov, Yu.M.; Naumov, I.V.; Pukhov, A.V.; Somenkov, V.A.; Syrykh, G.F.

    1997-01-01

    A new neutron spectrometer for investigation of inelastic neutron scattering on polycrystal microsamples under high pressure in sapphire and diamond anvils cells is described. The spectrometer is operating at the IBR-2 pulsed reactor in JINR. Parameters and methodical peculiarities of the spectrometer and the examples of experimental studies are given. (author)

  16. SO(10) supersymmetric grand unified theories

    Dermisek, Radovan

    The origin of the fermion mass hierarchy is one of the most challenging problems in elementary particle physics. In the standard model fermion masses and mixing angles are free parameters. Supersymmetric grand unified theories provide a beautiful framework for physics beyond the standard model. In addition to gauge coupling unification these theories provide relations between quark and lepton masses within families, and with additional family symmetry the hierarchy between families can be generated. We present a predictive SO(10) supersymmetric grand unified model with D 3 x U(1) family symmetry. The hierarchy in fermion masses is generated by the family symmetry breaking D 3 x U(1) → ZN → nothing. This model fits the low energy data in the charged fermion sector quite well. We discuss the prediction of this model for the proton lifetime in light of recent SuperKamiokande results and present a clear picture of the allowed spectra of supersymmetric particles. Finally, the detailed discussion of the Yukawa coupling unification of the third generation particles is provided. We find a narrow region is consistent with t, b, tau Yukawa unification for mu > 0 (suggested by b → sgamma and the anomalous magnetic moment of the muon) with A0 ˜ -1.9m16, m10 ˜ 1.4m16, m16 ≳ 1200 GeV and mu, M1/2 ˜ 100--500 GeV. Demanding Yukawa unification thus makes definite predictions for Higgs and sparticle masses.

  17. O conservadorismo patronal da grande imprensa brasileira

    Fonseca Francisco

    2003-01-01

    Full Text Available Através da análise da opinião dos editoriais dos quatro principais periódicos diários da grande imprensa, isto é, o Jornal do Brasil, O Globo, a Folha de S. Paulo e O Estado de S. Paulo - aqui considerados "aparelhos privados de hegemonia" -, este artigo procura desvendar os posicionamentos adotados perante a ordem social na Constituinte de 1987/1988, que também contribuem para compreender a reação à Consolidação das Leis do Trabalho. Observa-se, além do mais, as estratégias utilizadas para sua consecução. Conclui-se que, por mecanismos diversos, a grande imprensa contribuiu decisivamente para a introdução da agenda ideológica neoliberal no país, pois atuou de forma a "divulgar e vulgarizar" as idéias pertinentes a este ideário e de forma militantemente conservadora e patronal.

  18. Aprovechamiento de Salto Grande Argentina – Uruguay

    Bongiovanni, M.

    1979-12-01

    Full Text Available The power harnessing of Salto Grande will be the first common project carried out by two South American Countries and this will foster greater integration of both countries. The project involves the following: — One 39 m-high dam — Two hydroelectric power plants — One international bridge — One shipping canal The benefits to be obtained from the project include: increase and improvement of the waterway network; increase of electricity production; railways and highway tie-ups between both countries; industrial development; increased availability of irrigation water; new tourist resorts; increase of fishing resources.

    El aprovechamiento hidroeléctrico de Salto Grande será el primer aprovechamiento común a dos países sudamericanos, lo que permitirá una mayor integración entre ellos. Consta de las siguientes obras: _ una presa de 39 m de altura; _ dos centrales hidroeléctricas; _ un puente internacional; _ un canal de navegación, etc. Entre los beneficios que se obtendrán destacan: aumento y mejora de la red de navegación; aumento de la producción eléctrica; enlace de las vías de ferrocarril y carreteras entre los dos países; desarrollo industrial; aumento de la disponibilidad de agua de riego; creación de zonas de turismo, e incremento de la riqueza piscícola.

  19. Feasibility studies for the Forward Spectrometer

    Biernat, Jacek

    2015-01-01

    The Forward Spectrometer designed for the P-barANDA detector will consist of many different detector systems allowing for precise track reconstruction and particle identification. Feasibility studies for Forward Spectrometer done by means of specific reactions will be presented. In the first part of the paper, results of simulations focussing on rate estimates of the tracking stations based on straw tubes will be presented. Next, the importance of the Forward Tracker will be demonstrated through the reconstruction of the ψ(4040) → DD-bar decay. Finally, results from the analysis of the experimental data collected with a straw tube prototype designed and constructed at the Research Center in Juelich will be discussed. (paper)

  20. Sample changer for X-ray spectrometer

    Kaestner, F.; Bisch, H.

    1977-01-01

    A sample planchette with several samples in a spectrometer is rotated so as to position each sample in succession in a counting position. To change the planchette, the cover of the spectrometer raises together with the planchette and rotates to the side into a vertical magazine. The planchette is unhooked onto a tray which rapidly moves to a position above the cover, and the next planchette in the magazine stack moves upwards on a tray and is hooked to the cover and taken to the counting station. Three chains ensure the movement of the planchette trays in the magazine, one for raising the uncounted samples up the magazine, one for shifting the counted ones to the upper stack, and one to move the counted planchettes higher up the magazine. The movement of the chains is controlled by microswitches. (ORU) [de

  1. A 4π dilepton spectrometer: PEPSI

    Buda, A.; Bacelar, J.C.S.; Balanda, A.; Klinken, J. van; Sujkowski, Z.; Woude, A. van der

    1993-01-01

    A novel positron-electron pair spectroscopy instrument (PEPSI) was designed to measure transitions in the energy region 10-40 MeV. It consists of Nd 2 Fe 14 B permanent magnets forming a compact 4π magnetic filter consisting of 12 positron and 20 electron mini-orange-like spectrometers. The response function of PEPSI has been measured with mono-energetic beams of electrons from 5 to 20 MeV. The PEPSI spectrometer was used for measuring the internal pair conversion coefficient (α π ) of the 15.1 MeV M1 transition from a J π =1 + state to the ground state in 12 C. Our experimental value of α π =(3.3±0.5)x10 -3 is in good agreement with theoretical estimates. (orig.)

  2. A 4 π dilepton spectrometer: PEPSI

    Buda, A.; Bacelar, J. C. S.; Bałanda, A.; van Klinken, J.; Sujkowski, Z.; van der Woude, A.

    1993-11-01

    A novel positron-electron pair spectroscopy instrument (PEPSI) was designed to measure transitions in the energy region 10-40 MeV. It consists of Nd 2Fe 14B permanent magnets forming a compact 4 π magnetic filter consisting of 12 positron and 20 electron mini-orange-like spectrometers. The response function of PEPSI has been measured with mono-energetic beams of electrons from 5 to 20 MeV. The PEPSI spectrometer was used for measuring the internal pair conversion coefficient ( απ) of the 15.1 MeV M1 transition from a Jπ = 1 + state to the ground state in 12C. Our experimental value of απ = (3.3 ± 0.5) × 10 -3 is in good agreement with theoretical estimates.

  3. Inelastic rotor spectrometer at the Harwell Linac

    Boland, B.C.

    1983-01-01

    The spectrometer is designed to measure energy transfer from 50 MeV to 400 MeV covering a range of Q values from 1 to 15 A - 1 . Particular emphasis has been placed on the low Q counter banks where measurements at low Q reduce multiphonon contributions in vibrational spectra, diffusional broadening in liquids and allow measurements to be made on magnetic excitations. All indications are that the energy resolution is as predicted and is certainly twice as good as that of any other spectrometer presently available to the UK users at these energy transfers. Backgrounds on the high angle banks 24 0 to 94 0 are excellent but at the low angles are too high at present for anything but hydrogenous samples. Tests have shown that much of this background comes from the main beam in the area of the collimation between the chopper and the sample, and steps are being taken to improve this area

  4. The Harwell back-scattering spectrometer

    Windsor, C.G.; Bunce, L.J.; Borcherds, P.H.; Cole, I.; Fitzmaurice, M.; Johnson, D.A.G.; Sinclair, R.N.

    1976-01-01

    Neutron diffraction spectra in which both high resolution (Δ Q/Q approximately equal to 0.003) and high intensity are maintained up to scattering vectors as high as 30A -1 (sin theta/lambda = 2.5) have been obtained with the back-scattering spectrometer (BSS) recently installed on the Harwell electron linac. The theory behind the spectrometer design is described, and it is shown how the above resolution requirement leads to its basic features of a 12m incident flight path, a 2m scattering flight path and a scattering angle (2theta) acceptance from 165 0 to 175 0 . Examples of the resolution, intensity and background are given. It is shown that the problem of frame overlap may be overcome by using an absorbing filter. (author)

  5. Cryogenic system for a superconducting spectrometer

    Porter, J.

    1983-03-01

    The Heavy Ion Spectrometer System (HISS) relies upon superconducting coils of cryostable, pool boiling design to provide a maximum particle bending field of 3 tesla. This paper describes the cryogenic facility including helium refrigeration, gas management, liquid nitrogen system, and the overall control strategy. The system normally operates with a 4 K heat load of 150 watts; the LN 2 circuits absorb an additional 4000 watts. 80K intercept control is by an LSI 11 computer. Total available refrigeration at 4K is 400 watts using reciprocating expanders at the 20K and 4K level. The minicomputer has the capability of optimizing overall utility input cost by varying operating points. A hybrid of pneumatic, analog, and digital control is successful in providing full time unattended operation. The 7m diameter magnet/cryostat assembly is rotatable through 180 degrees to provide a variety of spectrometer orientations

  6. Alignment of the ATLAS central muon spectrometer

    Chevallier, F

    2008-01-01

    The muon spectrometer of the ATLAS experiment is one of the largest detectors ever built. At the LHC, new physics signs could appear through high momenta muons (1 TeV). Identification and precise momentum measurement of such muons are two of the main challenges of the ATLAS muon spectrometer. In order to get a good resolution for high energy muons (i.e. 10% at 1 TeV), the accuracy on the alignment of precision chambers must be of the order of 50 microns. Several procedures have been developed to reach such a precision. This document describes complementary techniques used to align the muon sub-detectors, and their results : the optical system, the muon cosmic rays and the straight tracks coming from collisions.

  7. The SeaQuest Spectrometer at Fermilab

    Aidala, C.A.; et al.

    2017-06-29

    The SeaQuest spectrometer at Fermilab was designed to detect oppositely-charged pairs of muons (dimuons) produced by interactions between a 120 GeV proton beam and liquid hydrogen, liquid deuterium and solid nuclear targets. The primary physics program uses the Drell-Yan process to probe antiquark distributions in the target nucleon. The spectrometer consists of a target system, two dipole magnets and four detector stations. The upstream magnet is a closed-aperture solid iron magnet which also serves as the beam dump, while the second magnet is an open aperture magnet. Each of the detector stations consists of scintillator hodoscopes and a high-resolution tracking device. The FPGA-based trigger compares the hodoscope signals to a set of pre-programmed roads to determine if the event contains oppositely-signed, high-mass muon pairs.

  8. Associated Particle Tagging (APT) in Magnetic Spectrometers

    Jordan, David V.; Baciak, James E.; Stave, Sean C.; Chichester, David; Dale, Daniel; Kim, Yujong; Harmon, Frank

    2012-10-16

    Summary In Brief The Associated Particle Tagging (APT) project, a collaboration of Pacific Northwest National Laboratory (PNNL), Idaho National Laboratory (INL) and the Idaho State University (ISU)/Idaho Accelerator Center (IAC), has completed an exploratory study to assess the role of magnetic spectrometers as the linchpin technology in next-generation tagged-neutron and tagged-photon active interrogation (AI). The computational study considered two principle concepts: (1) the application of a solenoidal alpha-particle spectrometer to a next-generation, large-emittance neutron generator for use in the associated particle imaging technique, and (2) the application of tagged photon beams to the detection of fissile material via active interrogation. In both cases, a magnetic spectrometer momentum-analyzes charged particles (in the neutron case, alpha particles accompanying neutron generation in the D-T reaction; in the tagged photon case, post-bremsstrahlung electrons) to define kinematic properties of the relevant neutral interrogation probe particle (i.e. neutron or photon). The main conclusions of the study can be briefly summarized as follows: Neutron generator: • For the solenoidal spectrometer concept, magnetic field strengths of order 1 Tesla or greater are required to keep the transverse size of the spectrometer smaller than 1 meter. The notional magnetic spectrometer design evaluated in this feasibility study uses a 5-T magnetic field and a borehole radius of 18 cm. • The design shows a potential for 4.5 Sr tagged neutron solid angle, a factor of 4.5 larger than achievable with current API neutron-generator designs. • The potential angular resolution for such a tagged neutron beam can be less than 0.5o for modest Si-detector position resolution (3 mm). Further improvement in angular resolution can be made by using Si-detectors with better position resolution. • The report documents several features of a notional generator design incorporating the

  9. Neutron spectrometer for improved SNM search.

    Vance, Andrew L.; Aigeldinger, Georg

    2007-03-01

    With the exception of large laboratory devices with very low sensitivities, a neutron spectrometer have not been built for fission neutrons such as those emitted by special nuclear materials (SNM). The goal of this work was to use a technique known as Capture Gated Neutron Spectrometry to develop a solid-state device with this functionality. This required modifications to trans-stilbene, a known solid-state scintillator. To provide a neutron capture signal we added lithium to this material. This unique triggering signal allowed identification of neutrons that lose all of their energy in the detector, eliminating uncertainties that arise due to partial energy depositions. We successfully implemented a capture gated neutron spectrometer and were able to distinguish an SNM like fission spectrum from a spectrum stemming from a benign neutron source.

  10. Solar maximum ultraviolet spectrometer and polarimeter

    Tandberg-Hanssen, E.; Woodgate, B. E.; Brandt, J. C.; Chapman, R. D.; Hyder, C. L.; Michalitsianos, A. G.; Shine, R. A.; Athay, R. G.; Beckers, J. M.; Bruner, E. C.

    1979-01-01

    The objectives of the UVSP experiment are to study solar ultraviolet radiations, particularly from flares and active regions, and to measure constituents in the terrestrial atmosphere by the extinction of sunlight at satellite dawn and dusk. The instrument is designed to observe the Sun at a variety of spectral and spatial resolutions in the range from 1150 to 3600 A. A Gregorian telescope with effective focal length of 1.8 m is used to feed a 1 m Ebert-Fastie spectrometer. A polarimeter containing rotatable magnesium fluoride waveplates is included behind the spectrometer entrance slit and will allow all four Stokes parameters to be determined. Velocities on the Sun can also be measured. The instrument is controlled by a computer which can interact with the data stream to modify the observing program. The observing modes, including rasters, spectral scans, velocity measurements, and polarimetry, are also described along with plans for mission operations, data handling, and analysis of the observations.

  11. The transition-edge EBIT microcalorimeter spectrometer

    Betancourt-Martinez, Gabriele L.; Adams, Joseph; Bandler, Simon; Beiersdorfer, Peter; Brown, Gregory; Chervenak, James; Doriese, Randy; Eckart, Megan; Irwin, Kent; Kelley, Richard; Kilbourne, Caroline; Leutenegger, Maurice; Porter, F. S.; Reintsema, Carl; Smith, Stephen; Ullom, Joel

    2014-07-01

    The Transition-edge EBIT Microcalorimeter Spectrometer (TEMS) is a 1000-pixel array instrument to be delivered to the Electron Beam Ion Trap (EBIT) facility at the Lawrence Livermore National Laboratory (LLNL) in 2015. It will be the first fully operational array of its kind. The TEMS will utilize the unique capabilities of the EBIT to verify and benchmark atomic theory that is critical for the analysis of high-resolution data from microcalorimeter spectrometers aboard the next generation of x-ray observatories. We present spectra from the present instrumentation at EBIT, as well as our latest results with time-division multiplexing using the current iteration of the TEMS focal plane assembly in our test platform at NASA/GSFC.

  12. MEMS tunable grating micro-spectrometer

    Tormen, Maurizio; Lockhart, R.; Niedermann, P.; Overstolz, T.; Hoogerwerf, A.; Mayor, J.-M.; Pierer, J.; Bosshard, C.; Ischer, R.; Voirin, G.; Stanley, R. P.

    2017-11-01

    The interest in MEMS based Micro-Spectrometers is increasing due to their potential in terms of flexibility as well as cost, low mass, small volume and power savings. This interest, especially in the Near-Infrared and Mid- Infrared, ranges from planetary exploration missions to astronomy, e.g. the search for extra solar planets, as well as to many other terrestrial fields of application such as, industrial quality and surface control, chemical analysis of soil and water, detection of chemical pollutants, exhausted gas analysis, food quality control, process control in pharmaceuticals, to name a few. A compact MEMS-based Spectrometer for Near- Infrared and Mid-InfraRed operation have been conceived, designed and demonstrated. The design based on tunable MEMS blazed grating, developed in the past at CSEM [1], achieves state of the art results in terms of spectral resolution, operational wavelength range, light throughput, overall dimensions, and power consumption.

  13. An intense transmission spectrometer for ISIS

    Newport, R.J.; Howells, W.S.

    1986-07-01

    The report seeks to outline a design for an intense transmission spectrometer (ITS) suitable for installation on the pulsed neutron source ISIS. The performance of the instrument is evaluated and several examples of the areas of science made accessible are discussed. It is shown that the proposed design will represent a scientifically valuable and cost-effective addition to the present suite of ISIS instruments. (author)

  14. Contamination measurements with quadrupole mass spectrometer

    Bohatka, S.; Berecz, I.; Langer, G.

    1981-01-01

    A sensitive quadrupole mass spectrometer of our own construction was used for different purity measurements. The analysis of gases in operating rooms showed a 1 ppm-10 5 ppm concentration of narcotics and helped to develop an effective and cheap method for regenerating narcotic filters. We regularly control the gases used in radioactive pollution measurements by internal GM counters and in radiocarbon dating technique. Combustion products and the gases of a fermenter are investigated for industrial application. (orig.) [de

  15. Single crystal spectrometer FOX at KENS

    Takahashi, M.

    2001-01-01

    Single crystal spectrometer FOX installed at H1 thermal neutron line on KENS has been renewed recently for the measurement of very weak scattering. We have installed a multidetector system of 36 linearly placed 3 He detectors with collimators instead of former four-circle diffractometer and scintillator detectors. Though the system is quite simple, a large two-dimensional reciprocal space is observed effectively with high S/N rate on new FOX. (author)

  16. Resolution of a triple axis spectrometer

    Nielsen, Mourits; Bjerrum Møller, Hans

    1969-01-01

    A new method for obtaining the resolution function for a triple-axis neutron spectrometer is described, involving a combination of direct measurement and analytical calculation. All factors which contribute to the finite resolution of the instrument may be taken into account, and Gaussian...... or experimentally determined probability distributions may be used. The application to the study of the dispersion relation for excitations in a crystal is outlined...

  17. Frequency-feedback cavity enhanced spectrometer

    Hovde, David Christian; Gomez, Anthony

    2015-08-18

    A spectrometer comprising an optical cavity, a light source capable of producing light at one or more wavelengths transmitted by the cavity and with the light directed at the cavity, a detector and optics positioned to collect light transmitted by the cavity, feedback electronics causing oscillation of amplitude of the optical signal on the detector at a frequency that depends on cavity losses, and a sensor measuring the oscillation frequency to determine the cavity losses.

  18. Mobile environment for an emission spectrometer

    Radziak, Kamil; Litwin, Dariusz; Galas, Jacek; Tyburska-Staniewska, Anna; Ramsza, Andrzej

    2017-08-01

    The paper describes a mobile application to be used in a chemical analytical laboratory. The program running under the control of Android operating system allows for preview of measurements recorded by the emission spectrometer. Another part of the application monitors operational and configuration parameters of the device in real time. The first part of this paper includes an overview of the atomic spectrometry. The second part contains a description of the application and its further potential development direction.

  19. Calibration of a leak detection spectrometer

    Geller, R.

    1958-01-01

    This paper describes a study of the possible methods for calibrating a leak detection spectrometer, and the estimation of outputs from the leaks is considered. With this in mind the question of sensitivity of leak detection is tackled on a very general level; first the sensitivity of the isolated instrument is determined, and then the sensitivity of an instrument connected to an installation where leaks may be suspected. Finally, practical solutions are proposed. (author) [fr

  20. Superconducting RF separator for Omega Spectrometer

    1977-01-01

    The photo shows an Nb-deflector for the superconducting RF separator ready for installation in its cryostat (visible at the back). Each deflector was about 3 m long. L. Husson and P. Skacel (Karlsruhe) stand on the left, A. Scharding (CERN) stands on the right. This particle separator, the result of a collaboration between the Gesellshaft für Kernforschung, Karlsruhe, and CERN was installed in the S1 beam line to Omega spectrometer. (See Annual Report 1977.)

  1. Some characteristics of a miniature neutron spectrometer

    Sekimoto, H.; Oishi, K.; Hojo, K.; Hojo, T.

    1984-01-01

    Some characteristics of an NE213 miniature spherical spectrometer for in-assembly fast-neutron spectrometry were measured. As the bubbling time changed, the pulse-height did not change appreciably, but the n-γ discrimination characteristics changed considerably. As the count rate changed, the pulse-height did not change appreciably, and the change of the n-γ discrimination characteristics was acceptable. The neutron response function was measured to be almost isotropic except for the backward direction. (orig.)

  2. The VESUVIO Spectrometer Now and When?

    Seel, A G; Krzystyniak, M; Fernandez-Alonso, F

    2014-01-01

    The current layout and mechanics of the VESUVIO spectrometer are presented in light of spectroscopic measurements using electron-volt neutrons. A brief background to the theoretical framework of deep inelastic neutron scattering is presented, with focus on data collection and instrumental design. The current capabilities and research themes for VESUVIO are discussed, and possible future instrumental developments highlighted which will enhance the instrument's ability to meet scientific inquiry and expectation

  3. The VESUVIO Spectrometer Now and When?

    Seel, A. G.; Krzystyniak, M.; Fernandez-Alonso, F.

    2014-12-01

    The current layout and mechanics of the VESUVIO spectrometer are presented in light of spectroscopic measurements using electron-volt neutrons. A brief background to the theoretical framework of deep inelastic neutron scattering is presented, with focus on data collection and instrumental design. The current capabilities and research themes for VESUVIO are discussed, and possible future instrumental developments highlighted which will enhance the instrument's ability to meet scientific inquiry and expectation.

  4. A new thermal ionisation mass spectrometer

    Haines, C.; Merren, T.O.; Unsworth, W.D.

    1979-01-01

    The Isomass 54E, a new thermal ionisation mass spectrometer for precise measurements of isotopic composition is described in detail. It combines the fruits of three development pro ects, viz. automation, energy filters and extended geometry with existing micromass expertise and experience. The hardware and software which are used for the automation as well as the energy filter used, are explained. The 'extended geometry' ion optical system adopted for better performance is discussed in detail. (K.B.)

  5. Hypernuclear physics with a neutral meson spectrometer

    Peng, J.C.

    1993-01-01

    The (K - , π degrees) reaction, which complements the (K - , π - ) and the (π + , K + ) reactions, offers another means to study hypernuclear physics. The physics motivation for measuring the (K - , π degrees) reaction is discussed. The feasibility for detecting π degrees using the LAMPF Neutral Meson Spectrometer is studied with Monte-Carlo simulations. We conclude that the (K - , π degrees) reaction can be well measured at existing kaon beam lines

  6. Nuclear quadrupole resonance spectrometer for chlorine compounds

    Lasanda, J.

    1976-01-01

    An NQR spectrometer is described based on a superregenerative oscillator for high sensitivity. The application of a Pound-Knight type oscillator using field effect transistors resulted in higher stability of oscillation amplitude in the desired range of 10 to 50 MHz. The use of a current source allowed to set good signal-to-noise ratio independently of the amplitude of oscillations. For synchronizing of both oscillators a balanced modulator was used. (author)

  7. Fourier Transform Spectrometer Controller for Partitioned Architectures

    Tamas-Selicean, Domitian; Keymeulen, D.; Berisford, D.

    2013-01-01

    The current trend in spacecraft computing is to integrate applications of different criticality levels on the same platform using no separation. This approach increases the complexity of the development, verification and integration processes, with an impact on the whole system life cycle. Resear......, such as avionics and automotive. In this paper we investigate the challenges of developing and the benefits of integrating a scientific instrument, namely a Fourier Transform Spectrometer, in such a partitioned architecture....

  8. One module of the ALICE photon spectrometer

    Maximilien Brice

    2006-01-01

    The first module for the ALICE photon spectrometer has been completed. Each of the five modules will contain 3584 lead-tungstate crystals, a material as transparent as ordinary silica glass but with nearly four times the density. When a high-energy particle passes through one of these crystals it will scintillate, allowing the energy of electrons, positrons and photons to be measured through the 17 920 detection channels.

  9. Two-lens spectrometer for. beta. polarimetry

    Holdsworth, D; Paul, D [Toronto Univ., Ontario (Canada). Dept. of Physics

    1984-06-01

    A test spectrometer has been built having four degrees of freedom which have been varied to optimize the transmission in a configuration in which the image distance is large compared to the object distance. Iron-clad magnets of 15 cm effective inside diameter were used. Within the limits of the primary magnet field, the optimized transmission T (%. of 4..pi.. sr) increases as the source is advanced through the magnet towards the polarimeter, approximately as T=5.1 exp(zsub(s)/10.5), where zsub(s) is in cm, measured from the position of peak axial field. When the source-image distance is 1.8 m the optimum separation of the peak axial fields of the magnets is 67+-1 cm and the spectrometer transmission is the same for parallel or antiparallel fields. When operating in the optimum configuration, the spectrometer accepts particles with initial trajectories from 18/sup 0/ to 42/sup 0/ relative to the axis and delivers them at the target with half-angle of convergence less than 4.1/sup 0/.

  10. Miniature Neutron-Alpha Activation Spectrometer

    Rhodes, E.; Goldsten, J.

    2001-01-01

    We are developing a miniature neutron-alpha activation spectrometer for in situ analysis of samples including rocks, fines, ices, and drill cores, suitable for a lander or Rover platform, that would meet the severe mass, power, and environmental constraints of missions to the outer planets. In the neutron-activation mode, a gamma-ray spectrometer will first perform a penetrating scan of soil, ice, and loose material underfoot (depths to 10 cm or more) to identify appropriate samples. Chosen samples will be analyzed in bulk in neutron-activation mode, and then the sample surfaces will be analyzed in alpha-activation mode using Rutherford backscatter and x-ray spectrometers. The instrument will provide sample composition over a wide range of elements, including rock-forming elements (such as Na, Mg, Si, Fe, and Ca), rare earths (Sm and Eu for example), radioactive elements (K, Th, and U), and light elements present in water, ices, and biological materials (mainly H, C, O, and N). The instrument is expected to have a mass of about l kg and to require less than 1 W power. Additional information is contained in the original extended abstract.

  11. Silicon Microleaks for Inlets of Mass Spectrometers

    Harpold, Dan; Hasso, Niemann; Jamieson, Brian G.; Lynch, Bernard A.

    2009-01-01

    Microleaks for inlets of mass spectrometers used to analyze atmospheric gases can be fabricated in silicon wafers by means of photolithography, etching, and other techniques that are commonly used in the manufacture of integrated circuits and microelectromechanical systems. The microleaks serve to limit the flows of the gases into the mass-spectrometer vacuums to specified very small flow rates consistent with the capacities of the spectrometer vacuum pumps. There is a need to be able to precisely tailor the dimensions of each microleak so as to tailor its conductance to a precise low value. (As used here, "conductance" signifies the ratio between the rate of flow in the leak and the pressure drop from the upstream to the downstream end of the leak.) To date, microleaks have been made, variously, of crimped metal tubes, pulled glass tubes, or frits. Crimped-metal and pulled-glass-tube microleaks cannot readily be fabricated repeatably to precise dimensions and are susceptible to clogging with droplets or particles. Frits tend to be differentially chemically reactive with various gas constituents and, hence, to distort the gas mixtures to be analyzed. The present approach involving microfabrication in silicon largely overcomes the disadvantages of the prior approaches.

  12. High speed, High resolution terahertz spectrometers

    Kim, Youngchan; Yee, Dae Su; Yi, Miwoo; Ahn, Jaewook

    2008-01-01

    A variety of sources and methods have been developed for terahertz spectroscopy during almost two decades. Terahertz time domain spectroscopy (THz TDS)has attracted particular attention as a basic measurement method in the fields of THz science and technology. Recently, asynchronous optical sampling (AOS)THz TDS has been demonstrated, featuring rapid data acquisition and a high spectral resolution. Also, terahertz frequency comb spectroscopy (TFCS)possesses attractive features for high precision terahertz spectroscopy. In this presentation, we report on these two types of terahertz spectrometer. Our high speed, high resolution terahertz spectrometer is demonstrated using two mode locked femtosecond lasers with slightly different repetition frequencies without a mechanical delay stage. The repetition frequencies of the two femtosecond lasers are stabilized by use of two phase locked loops sharing the same reference oscillator. The time resolution of our terahertz spectrometer is measured using the cross correlation method to be 270 fs. AOS THz TDS is presented in Fig. 1, which shows a time domain waveform rapidly acquired on a 10ns time window. The inset shows a zoom into the signal with 100ps time window. The spectrum obtained by the fast Fourier Transformation (FFT)of the time domain waveform has a frequency resolution of 100MHz. The dependence of the signal to noise ratio (SNR)on the measurement time is also investigated

  13. Automation of a thermal ionisation mass spectrometer

    Pamula, A.; Leuca, M.; Albert, S.; Benta, Adriana

    2001-01-01

    A thermal ionization mass spectrometer was upgraded in order to be monitored by a PC. A PC-LMP-16 National Instruments data acquisition board was used for the ion current channel and the Hall signal channel. A dedicated interface was built to allow commands from the computer to the current supply of the analyzing magnet and to the high voltage unit of the mass spectrometer. A software application was worked out to perform the adjustment of the spectrometer, magnetic scanning and mass spectra acquisition, data processing and isotope ratio determination. The apparatus is used for isotope ratio 235 U/ 238 U determination near the natural abundance. A peak jumping technique is applied to choose between the 235 U and 238 U signal, by switching the high voltage applied to the ion source between two preset values. This avoids the delay between the acquisition of the peaks of interest, a delay that would appear in the case of a 'pure' magnetic scanning. Corrections are applied for the mass discrimination effects and a statistical treatment of the data is achieved. (authors)

  14. VERITAS: Versatile Triple-Axis Spectrometer

    Park, Sung Il

    2006-04-15

    Korea Atomic Energy Research Institute is planning to build a cold neutron triple-axis spectrometer at HANARO, the 30 MW research reactor. The spectrometer is expected to be completed in 2008 with the following configuration from the upstream to the downstream. Guide Supermirror m = 2, In-pile Straight Section, {approx} 5 m Curved Guide, {approx} 26 m w/ R 1500 m Straight Guide before the Instrument, {approx} 40 m Filters PG and Be Neutron Velocity Selector (Future) Monochromators Vertically Focusing Monochromators PG(002) and Heusler(111) Doubly Focusing Monochromators (Future) Monochromator-Sample Distance 2 m Collimation C1 Soller Collimators, 20', 40' 80'Beam Height at the Sample Table 1.5 m Sample-Analyzer Distance 1.0 m Collimation C2 Soller Collimators, 20', 40', 80' Radial Collimator Analyzers Horizontally Focusing Analyzers w/ Fixed Vertical Focusing PG(002) and Heusler(111) Analyzer-Detector Distance 0.5 m Detectors 5 cm Tube Detector 25 cm wide Position Sensitive Detector Once completed, the neutron flux at sample is expected to surpass that of SPINS at NCNR, making this instrument one of the most powerful 2nd generation cold neutron triple-axis spectrometers in the world.

  15. VERITAS: Versatile Triple-Axis Spectrometer

    Park, Sung Il

    2006-04-01

    Korea Atomic Energy Research Institute is planning to build a cold neutron triple-axis spectrometer at HANARO, the 30 MW research reactor. The spectrometer is expected to be completed in 2008 with the following configuration from the upstream to the downstream. Guide Supermirror m = 2, In-pile Straight Section, ∼ 5 m Curved Guide, ∼ 26 m w/ R 1500 m Straight Guide before the Instrument, ∼ 40 m Filters PG and Be Neutron Velocity Selector (Future) Monochromators Vertically Focusing Monochromators PG(002) and Heusler(111) Doubly Focusing Monochromators (Future) Monochromator-Sample Distance 2 m Collimation C1 Soller Collimators, 20', 40' 80'Beam Height at the Sample Table 1.5 m Sample-Analyzer Distance 1.0 m Collimation C2 Soller Collimators, 20', 40', 80' Radial Collimator Analyzers Horizontally Focusing Analyzers w/ Fixed Vertical Focusing PG(002) and Heusler(111) Analyzer-Detector Distance 0.5 m Detectors 5 cm Tube Detector 25 cm wide Position Sensitive Detector Once completed, the neutron flux at sample is expected to surpass that of SPINS at NCNR, making this instrument one of the most powerful 2nd generation cold neutron triple-axis spectrometers in the world

  16. What Happened with Spectrometer Magnet 2B

    Green, Michael A.

    2010-01-01

    The spectrometer solenoid is supposed to be the first magnets installed in MICE (1)-(4). This report described what happened during the test of the MICE spectrometer solenoid 2B. First, the report describes the temperatures in the magnet, the cooler top plate and the shield during the run where the magnet quenched at 258 A. During this quench, a lead between the bottom of the HTS leads and the diode bank burned out causing the magnet to quench. Second, three methods for measuring the net heat flow into the cold mass are described. Third, there is a discussion of possible resistive heating in the HTS leads between liquid helium temperature and the copper plate, which is at about 50 K. Fourth, there is a discussion of the measured first stage heat loads in the magnet, when there is no current in the magnet. The first stage heat load calculations are based on knowing the first stage temperatures of the three two-stage pulse tube coolers and the single stage GM cooler. Fifth, the estimated heat load to the first stage when the magnet has current in it is discussed. Sixth, there is a comparison of the stage 1 heat loads in magnet 1A (5), magnet 2A (6), and magnet 2B (7). Finally there is a discussion of recommended changes for improving the spectrometer solenoids so that the coolers can keep them cold.

  17. Advances in miniature spectrometer and sensor development

    Malinen, Jouko; Rissanen, Anna; Saari, Heikki; Karioja, Pentti; Karppinen, Mikko; Aalto, Timo; Tukkiniemi, Kari

    2014-05-01

    Miniaturization and cost reduction of spectrometer and sensor technologies has great potential to open up new applications areas and business opportunities for analytical technology in hand held, mobile and on-line applications. Advances in microfabrication have resulted in high-performance MEMS and MOEMS devices for spectrometer applications. Many other enabling technologies are useful for miniature analytical solutions, such as silicon photonics, nanoimprint lithography (NIL), system-on-chip, system-on-package techniques for integration of electronics and photonics, 3D printing, powerful embedded computing platforms, networked solutions as well as advances in chemometrics modeling. This paper will summarize recent work on spectrometer and sensor miniaturization at VTT Technical Research Centre of Finland. Fabry-Perot interferometer (FPI) tunable filter technology has been developed in two technical versions: Piezoactuated FPIs have been applied in miniature hyperspectral imaging needs in light weight UAV and nanosatellite applications, chemical imaging as well as medical applications. Microfabricated MOEMS FPIs have been developed as cost-effective sensor platforms for visible, NIR and IR applications. Further examples of sensor miniaturization will be discussed, including system-on-package sensor head for mid-IR gas analyzer, roll-to-roll printed Surface Enhanced Raman Scattering (SERS) technology as well as UV imprinted waveguide sensor for formaldehyde detection.

  18. Multiplate ionization total absorption spectrometer with a compressed gas

    Baskakov, V.I.; Dolgoshein, B.A.; Kantserov, V.A.

    1978-01-01

    The characteristics of a multiplate total absorption spectrometer working with the compressed xenon (up to 25 atm) containing up to 23 radiation lengths of matter are studied. The dependence of the spectrometer energy resolution on the detecting matter density, on the material and thickness of the absorber plates has been studied. The ability of the spectrometer with a tungsten absorber to select hadrons and electrons with P=6 GeV/c by total energy release and characteristics of the cascade longitudinal development has been also studied. The gas spectrometer as it is shown differs quite slightly from the similar spectrometer with liquid argon as for its time resolution it is much better

  19. La masa de los grandes impactores

    Parisi, M. G.; Brunini, A.

    Los planetas han sido formados fundamentalmente acretando masa a través de colisiones con planetesimales sólidos. La masa más grande de la distribución de planetesimales y las masas máxima y mínima de los impactores, han sido calculadas usando los valores actuales del período y de la inclinación de los planetas (Lissauer & Safronov 1991; Parisi & Brunini 1996). Recientes investigaciones han mostrado, que las órbitas de los planetas gigantes no han sufrido variaciones con el tiempo, siendo su movimiento regular durante su evolución a partir de la finalización de la etapa de acreción (Laskar 1990, 1994). Por lo tanto, la eccentricidad actual de los planetas gigantes se puede utilizar para imponer una cota máxima a las masas y velocidades orbitales de los grandes impactores. Mediante un simple modelo dinámico, y considerando lo arriba mencionado, obtenemos la cota superior para la masa del planetesimal más grande que impactó a cada planeta gigante al final de su etapa de acreción. El resultado más importante de este trabajo es la estimación de la masa máxima permitida para impactar a Júpiter, la cúal es ~ 1.136 × 10 -1, siendo en el caso de Neptuno ~ 3.99 × 10 -2 (expresada en unidades de la masa final de cada planeta). Además, fue posible obtener la velocidad orbital máxima permitida para los impactores como una función de su masa, para cada planeta. Las cotas obtenidas para la masa y velocidad de los impactores de Saturno y Urano (en unidades de la masa y velocidad final de cada planeta respectivamente) son casi las mismas que las obtenidas para Júpiter debido a que estos tres planetas poseen similar eccentricidad actual. Nuestros resultados están en buen acuerdo con los obtenidos por Lissauer & Safronov (1991). Estas cotas podrían ser utilizadas para obtener la distribución de planetesimales en el Sistema Solar primitivo.

  20. [Design of Dual-Beam Spectrometer in Spectrophotometer for Colorimetry].

    Liu, Yi-xuan; Yan, Chang-xiang

    2015-07-01

    Spectrophotometers for colorimetry are usually composed of two independent and identical spectrometers. In order to reduce the volume of spectrophotometer for colorimetry, a design method of double-beam spectrometer is put forward. A traditional spectrometer is modified so that a new spectrometer can realize the function of double spectrometers, which is especially suitable for portable instruments. One slit is replaced by the double-slit, than two beams of spectrum can be detected. The working principle and design requirement of double-beam spectrometer are described. A spectrometer of portable spectrophotometer is designed by this method. A toroidal imaging mirror is used for the Czerny-Turner double-beam spectrometer in this paper, which can better correct astigmatism, and prevent the dual-beam spectral crosstalk. The results demonstrate that the double-beam spectrometer designed by this method meets the design specifications, with the spectral resolution less than 10 nm, the spectral length of 9.12 mm, and the volume of 57 mm x 54 mm x 23 mm, and without the dual-beam spectral overlap in the detector either. Comparing with a traditional spectrophotometer, the modified spectrophotometer uses a set of double-beam spectrometer instead of two sets of spectrometers, which can greatly reduce the volume. This design method can be specially applied in portable spectrophotometers, also can be widely applied in other double-beam spectrophotometers, which offers a new idea for the design of dual-beam spectrophotometers.

  1. Local grand unification and string theory

    Nilles, Hans Peter; Vaudrevange, Patrick K.S.

    2009-09-01

    The low energy effective action of string theory depends strongly on the process of compactification and the localization of fields in extra dimensions. Explicit string constructions towards the minimal supersymmetric standard model (MSSM) reveal interesting results leading to the concept of local grand unification. Properties of the MSSM indicate that we might live at a special location close to an orbifold fixed point rather than a generic point in Calabi-Yau moduli space. We observe an enhancement of (discrete) symmetries that have various implications for the properties of the MSSM such as proton stability as well as solutions to the flavor problem, the m-problem and the strong CP-problem. (orig.)

  2. A unified grand tour of theoretical physics

    Lawrie, Ian D

    2013-01-01

    A Unified Grand Tour of Theoretical Physics invites its readers to a guided exploration of the theoretical ideas that shape our contemporary understanding of the physical world at the fundamental level. Its central themes, comprising space-time geometry and the general relativistic account of gravity, quantum field theory and the gauge theories of fundamental forces, and statistical mechanics and the theory of phase transitions, are developed in explicit mathematical detail, with an emphasis on conceptual understanding. Straightforward treatments of the standard models of particle physics and cosmology are supplemented with introductory accounts of more speculative theories, including supersymmetry and string theory. This third edition of the Tour includes a new chapter on quantum gravity, focusing on the approach known as Loop Quantum Gravity, while new sections provide extended discussions of topics that have become prominent in recent years, such as the Higgs boson, massive neutrinos, cosmological perturba...

  3. Introduction to Grand Unified Theories. 12

    Wali, K.C.

    1989-01-01

    This chapter presents an introduction into Grand Unified Theories. After a discussion of the general features to be expected in any such theory, and of the motivations for them, a detailed presentation of SU(5) theory is given. The group structures, particle multiplets, gauge and Higgs bosons are explained. The two stages of spontaneous symmetry breaking via the Higgs model, are calculated individually and in combination. Fermion mass matrices and relations between quark and lepton masses are derived. predictions of SU(5) theory, calculated using renormalization group methods, are derived. The chapter ends with discussions that bring together particle physics and cosmology, including the baryon asymmetry problem, phase transitions in the very early universe, and singularities like domain walls, vortex lines and monopoles. (author). 9 refs.; 4 figs.; 5 tabs

  4. Supersymmetric grand unified theories and cosmology

    Lazarides, G.; Shafi, Q.

    1983-01-01

    By examining the behavior of supersymmetric grand unified theories (GUT's) in the very early universe we find two classes of realistic models. In one of them supersymmetry is broken at or near superheavy GUT scale. The cosmological implications of such models are expected to be similar to those of nonsupersymmetric GUT's. In the second class of models, the superheavy GUT scale is related to the supersymmetry-breaking scale in the manner of Witten. Two types of cosmological scenarios appear possible in this case, either with or without an intermediate (new) inflationary phase. They can be experimentally distinguished, since the former predicts an absence and the latter an observable number density of superheavy monopoles. A mechanism for generating baryon asymmetry in such models is pointed out

  5. Pitié pour les grandes villes !

    Jérôme Monnet

    1997-02-01

    Full Text Available Roger Caillois disait, en 1938, qu´il existe "une représentation de la grande ville, assez puissante sur les imaginations pour que jamais en pratique ne soit posée la question de son exactitude, créée de toute pièce par le livre, assez répandue néanmoins pour faire partie de l´atmosphère mentale collective et posséder par suite une certaine force de contrainte"(Le mythe et l´homme, p.156 [c´est lui qui souligne]. En 1996, la presse française a consacré dossiers et articles à "Habitat II...

  6. Preface to a GUT (Grand Unified Theory)

    Honig, W.

    1982-01-01

    A Grand Unified Theory (GUT) is proposed exhibiting relativistic invariance and based on a physical model for vacuum space consisting of the superposition of oppositely charged continuous fluids. Models for the photon, electron, neutrino, proton, etc., consist of separate unique variations in the relative densities of the fluids and their flow patterns. This GUT is also based on the use of transfinite axiomatic number forms and on a concept of metrical relativity which hopefully reconciles the many logical dichotomies in and between Special Relativity and Quantum Mechanics. These ideas result in a number of experimental proposals and predicted results which appear to be underivable from present paradigms, first among which is a physical model for the hidden variable of Quantum Mechanics. It is on these features that attention should rest. (Auth.)

  7. Higgsless grand unified theory breaking and trinification

    Carone, Christopher D.; Conroy, Justin M.

    2004-01-01

    Boundary conditions on an extra dimensional interval can be chosen to break bulk gauge symmetries and to reduce the rank of the gauge group. We consider this mechanism in models with gauge trinification. We determine the boundary conditions necessary to break the trinified gauge group directly down to that of the standard model. Working in an effective theory for the gauge-symmetry-breaking parameters on a boundary, we examine the limit in which the grand-unified theory-breaking-sector is Higgsless and show how one may obtain the low-energy particle content of the minimal supersymmetric standard model. We find that gauge unification is preserved in this scenario, and that the differential gauge coupling running is logarithmic above the scale of compactification. We compare the phenomenology of our model to that of four dimensional 'trinified' theories

  8. Grand unified models including extra Z bosons

    Li Tiezhong

    1989-01-01

    The grand unified theories (GUT) of the simple Lie groups including extra Z bosons are discussed. Under authors's hypothesis there are only SU 5+m SO 6+4n and E 6 groups. The general discussion of SU 5+m is given, then the SU 6 and SU 7 are considered. In SU 6 the 15+6 * +6 * fermion representations are used, which are not same as others in fermion content, Yukawa coupling and broken scales. A conception of clans of particles, which are not families, is suggested. These clans consist of extra Z bosons and the corresponding fermions of the scale. The all of fermions in the clans are down quarks except for the standard model which consists of Z bosons and 15 fermions, therefore, the spectrum of the hadrons which are composed of these down quarks are different from hadrons at present

  9. Review of freeboard: Grand Rapids Generating Station

    Groeneveld, J.L.; Harding, W.B.; Bonin, D.V.; Fuchs, D.M. [Acres Manitoba Ltd., Winnipeg, MB (Canada); Warner, B.J. [Manitoba Hydro, Winnipeg, MB (Canada)

    2001-10-01

    Constructed during the period 1960-1965, the Grand Rapids Generating Station is a 472 MW hydroelectric station located approximately 400 kilometres northwest of Winnipeg, Manitoba, on the Saskatchewan River. An intake structure, four penstocks, a four-unit plus house unit powerhouse, wing walls, extensive dyke structures and a four-bay spillway are the components of the generating station. A little over ten years ago, the Manitoba Hydro Dam Safety Program was initiated. The program included a detailed dam safety review of the Grand rapids Generating Station. A potential deficiency in the freeboard allowance for several of the earthen dykes was revealed by the review process. The dam safety guidelines sponsored by the Canadian Dam Association were not met. The occurrence of a 1:1000 year wind event from the critical direction when the reservoir was at or near its full supply level was compounded by the analysis. The establishment of a wind and wave monitoring program was included in the deficiency studies commissioned. The objective was to confirm the empirical estimates concerning wave height, the development and usage of a two dimensional numerical wave model, and additional freeboard analyses to refine estimates of the recurrence interval of the current level of protection. A statistical Monte Carlo analysis was performed in the case of the estimates of the recurrence interval to determine the joint probabilities of seasonal variations in wind direction, wind speed, and reservoir level. The estimate of the actual risk of overtopping was therefore refined, and the details pertaining to the methodology and the conclusions of the analysis are all included in the paper. 15 refs., 4 tabs., 9 figs.

  10. Perspective view over the Grand Canyon, Arizona

    2001-01-01

    This simulated true color perspective view over the Grand Canyon was created from Advanced Spaceborne Thermal Emission and Reflection Radiometer (ASTER) data acquired on May 12, 2000. The Grand Canyon Village is in the lower foreground; the Bright Angel Trail crosses the Tonto Platform, before dropping down to the Colorado Village and then to the Phantom Ranch (green area across the river). Bright Angel Canyon and the North Rim dominate the view. At the top center of the image the dark blue area with light blue haze is an active forest fire. ASTER is one of five Earth-observing instruments launched December 18, 1999, on NASA's Terra satellite. The instrument was built by Japan's Ministry of Economy, Trade and Industry. A joint U.S./Japan science team is responsible for validation and calibration of the instrument and the data products. The broad spectral coverage and high spectral resolution of ASTER provides scientists in numerous disciplines with critical information for surface mapping, and monitoring of dynamic conditions and temporal change. Example applications are: monitoring glacial advances and retreats; monitoring potentially active volcanoes; identifying crop stress; determining cloud morphology and physical properties; wetlands evaluation; thermal pollution monitoring; coral reef degradation; surface temperature mapping of soils and geology; and measuring surface heat balance. The U.S. science team is located at NASA's Jet Propulsion Laboratory, Pasadena, Calif. The Terra mission is part of NASA's Science Mission Directorate. Size: 5 km in foreground to 40 km Location: 36.3 degrees north latitude, 112 degrees west longitude Orientation: North-northeast at top Original Data Resolution: ASTER 15 meters Dates Acquired: May 12, 2000

  11. Phase transitions at finite chemical potential in grand unified theories

    Bailin, D.; Love, A.

    1984-01-01

    We discuss the circumstances in which non-zero chemical potentials might prevent symmetry restoration in phase transitions in the early universe at grand unification or partial unification scales. The general arguments are illustrated by consideration of SO(10) and SU(5) grand unified theories. (orig.)

  12. Fetal Outcomes among Grand Multiparous and Multiparous Women ...

    Objective: To compare fetal outcomes among grand multiparous (para 5-9) and multiparous (para 2-4) delivering in Mulago hospital, Uganda. Design: Prospective cohort study. Setting: Mulago hospital, Uganda. Subjects: One hundred and fifty six grand multiparous and multiparous women were recruited on admission in ...

  13. First report of Phytophthora ramorum infecting grand fir in California

    K.L. Riley; G.A. Chastagner

    2011-01-01

    Phytophthora ramorum was detected on grand fir in 2003 and 2005 in a Christmas tree plantation near Los Gatos, CA, in association with infected California bay laurel. Isolates derived from stem lesions were used to inoculate grand fir seedlings in two tests. Isolations from lesions on inoculated plants were positive for P. ramorum...

  14. Plants, arthropods, and birds of the Rio Grande [chapter 7

    Deborah M. Finch; Gale L. Wolters; Wang Yong; Mary Jean Mund

    1995-01-01

    Human populations have increased dramatically along the Rio Grande since European settlement. Human use of water for irrigation and consumption, and human use of land for agriculture, urban centers, livestock grazing, and recreation have changed Rio Grande ecosystems by altering flood cycles, channel geomorphology, upslope processes, and water quality and quantity....

  15. Research of the Rio Grande Ecosystem Management Program

    Deborah M. Finch

    2000-01-01

    This paper describes the mission, objectives, and preliminary results of the Middle Rio Grande Ecosystem Management Research Program managed at the Rocky Mountain Research Station's Albuquerque laboratory. This program was initiated in 1994 to address growing pressures to effectively manage the limited resources of the middle Rio Grande Basin. The program is...

  16. Elastoplasticidad anisotropa de metales en grandes deformaciones

    Caminero Torija, Miguel Angel

    El objetivo de este trabajo es el desarrollo de modelos y algoritmos numericos que simulen el comportamiento del material bajo estas condiciones en el contexto de programas de elementos finitos, dando como resultado predicciones mas precisas de los procesos de conformado y deformacion plastica en general. Para lograr este objetivo se han desarrollado diversas tareas destinadas a mejorar las predicciones en tres aspectos fundamentales. El primer aspecto consiste en la mejora de la descripcion del endurecimiento cinematico anisotropo en pequenas deformaciones, lo cual se ha realizado a traves de modelos y algoritmos implicitos de superficies multiples. Ha sido estudiada la consistencia de este tipo de modelos tanto si estan basados en una regla implicita similar a la de Mroz o en la regla de Prager. Ademas se han simulado los ensayos de Lamba y Sidebottom, obteniendo, en contra de la creencia general, muy buenas predicciones con la regla de Prager. Dichos modelos podrian ser extendidos de forma relativamente facil para considerar grandes deformaciones a traves de procedimientos en deformaciones logaritmicas, similares a los desarrollados en esta tesis y detallados a continuacion. El segundo aspecto consiste en la descripcion de la anisotropia elastoplastica inicial. Esto se ha conseguido mediante el desarrollo de modelos y algoritmos para plasticidad anisotropa en grandes deformaciones, bien ignorando la posible anisotropia elastica, bien considerandola simultaneamente con la anisotropia plastica. Para ello ha sido necesario desarrollar primero un nuevo algoritmo de elastoplasticidad anisotropa en pequenas deformaciones consistentemente linealizado y sin despreciar ningun termino, de tal forma que se conserve la convergencia cuadratica de los metodos de Newton. Este algoritmo en pequenas deformaciones ha servido para realizar la correccion plastica de dos algoritmos en grandes deformaciones. El primero de estos algoritmos es una variacion del clasico algoritmo de

  17. Progress in commercial TXRF spectrometer for semiconductors

    Nishihagi, K.

    2000-01-01

    In the scale down of ULSI devices, it is required to reduce contamination of metal or particle due to get higher yield. For the metallic contamination, we are trying to develop to get higher sensitivity in direct-TXRF method, however, VPD-TXRF is the most important method to get 10 7 to 10 8 atoms/cm 2 sensitivity. For the particle contamination, we have developed software to link TXRF spectrometer with particle counter because not only position or size but also composition analysis have got required. In semiconductor industries, there are two important changing for improvement on production management system as COO (Cost Of Ownership) or standardization. One is the size of wafer has changed from 200 mm to 300 mm. Against this, we have redesigned TXRF spectrometer for 300 mm wafer without down of sensitivity. The other is the production system has become completely automated. On this point, we have also redesigned to link TXRF spectrometer with SMIF (Standard Mechanical Interface) or FOUP (Front Opening Unified Pod) as mini-environment, and with SECS 2 (SEMI Equipment Communications Standard 2) or GEM 300 (Generic Equipment Model) as automatically standardization. We shall also introduce some applications about new materials using TXRF such as Ta 2 O 5 , ZrO 2 and HfO 2 for high-k materials, and also Ru, SRO and IrO 2 for electrode materials. Furthermore, we shall introduce our new equipment for thickness and composition analysis such as PZT, BST and MOCVD TiN thin films. (author)

  18. Metrology for terahertz time-domain spectrometers

    Molloy, John F.; Naftaly, Mira

    2015-12-01

    In recent years the terahertz time-domain spectrometer (THz TDS) [1] has emerged as a key measurement device for spectroscopic investigations in the frequency range of 0.1-5 THz. To date, almost every type of material has been studied using THz TDS, including semiconductors, ceramics, polymers, metal films, liquid crystals, glasses, pharmaceuticals, DNA molecules, proteins, gases, composites, foams, oils, and many others. Measurements with a TDS are made in the time domain; conversion from the time domain data to a frequency spectrum is achieved by applying the Fourier Transform, calculated numerically using the Fast Fourier Transform (FFT) algorithm. As in many other types of spectrometer, THz TDS requires that the sample data be referenced to similarly acquired data with no sample present. Unlike frequency-domain spectrometers which detect light intensity and measure absorption spectra, a TDS records both amplitude and phase information, and therefore yields both the absorption coefficient and the refractive index of the sample material. The analysis of the data from THz TDS relies on the assumptions that: a) the frequency scale is accurate; b) the measurement of THz field amplitude is linear; and c) that the presence of the sample does not affect the performance characteristics of the instrument. The frequency scale of a THz TDS is derived from the displacement of the delay line; via FFT, positioning errors may give rise to frequency errors that are difficult to quantify. The measurement of the field amplitude in a THz TDS is required to be linear with a dynamic range of the order of 10 000. And attention must be given to the sample positioning and handling in order to avoid sample-related errors.

  19. Ultra-compact MEMS FTIR spectrometer

    Sabry, Yasser M.; Hassan, Khaled; Anwar, Momen; Alharon, Mohamed H.; Medhat, Mostafa; Adib, George A.; Dumont, Rich; Saadany, Bassam; Khalil, Diaa

    2017-05-01

    Portable and handheld spectrometers are being developed and commercialized in the late few years leveraging the rapidly-progressing technology and triggering new markets in the field of on-site spectroscopic analysis. Although handheld devices were commercialized for the near-infrared spectroscopy (NIRS), their size and cost stand as an obstacle against the deployment of the spectrometer as spectral sensing components needed for the smart phone industry and the IoT applications. In this work we report a chip-sized microelectromechanical system (MEMS)-based FTIR spectrometer. The core optical engine of the solution is built using a passive-alignment integration technique for a selfaligned MEMS chip; self-aligned microoptics and a single detector in a tiny package sized about 1 cm3. The MEMS chip is a monolithic, high-throughput scanning Michelson interferometer fabricated using deep reactive ion etching technology of silicon-on-insulator substrate. The micro-optical part is used for conditioning the input/output light to/from the MEMS and for further light direction to the detector. Thanks to the all-reflective design of the conditioning microoptics, the performance is free of chromatic aberration. Complemented by the excellent transmission properties of the silicon in the infrared region, the integrated solution allows very wide spectral range of operation. The reported sensor's spectral resolution is about 33 cm-1 and working in the range of 1270 nm to 2700 nm; upper limited by the extended InGaAs detector. The presented solution provides a low cost, low power, tiny size, wide wavelength range NIR spectral sensor that can be manufactured with extremely high volumes. All these features promise the compatibility of this technology with the forthcoming demand of smart portable and IoT devices.

  20. Low energy x-ray spectrometer

    Woodruff, W.R.

    1981-01-01

    A subkilovolt spectrometer has been produced to permit high-energy-resolution, time-dependent x-ray intensity measurements. The diffracting element is a curved mica (d = 9.95A) crystal. To preclude higher order (n > 1) diffractions, a carbon x-ray mirror that reflects only photons with energies less than approx. 1.1 keV is utilized ahead of the diffracting element. The nominal energy range of interest is 800 to 900 eV. The diffracted photons are detected by a gold-surface photoelectric diode designed to have a very good frequency response, and whose current is recorded on an oscilloscope. A thin, aluminium light barrier is placed between the diffracting crystal and the photoelectric diode detector to keep any uv generated on or scattered by the crystal from illuminating the detector. High spectral energy resolution is provided by many photocathodes between 8- and 50-eV wide placed serially along the diffracted x-ray beam at the detector position. The spectrometer was calibrated for energy and energy dispersion using the Ni Lα 1 2 lines produced in the LLNL IONAC accelerator and in third order using a molybdenum target x-ray tube. For the latter calibration the carbon mirror was replaced by one surfaced with rhodium to raise the cut-off energy to about 3 keV. The carbon mirror reflection dependence on energy was measured using one of our Henke x-ray sources. The curved mica crystal diffraction efficiency was measured on our Low-Energy x-ray (LEX) machine. The spectrometer performs well although some changes in the way the x-ray mirror is held are desirable. 16 figures

  1. Microprocessor-controlled portable neutron spectrometer

    Hunt, G.F.; Kaifer, R.C.; Slaughter, D.R.; Strout, R.E. II; Rueppel, D.W.

    1979-01-01

    A neutron spectrometer that acquires and unfolds data in the field has been developed for use in the energy range from 1 to 20 MeV. The system includes an NE213 organic scintillation detector, automatic gain stabilization, automatically stabilized pulseshape discrimination, an LSl-11 microprocessor for control and data reduction, and a multichannel analyzer for data acquisition. The system, with the exception of the multichannel analyzer, is mounted in a suitcase 47 by 66 by 23.5 cm. The mass is 23.5 kg

  2. Simplified monte carlo simulation for Beijing spectrometer

    Wang Taijie; Wang Shuqin; Yan Wuguang; Huang Yinzhi; Huang Deqiang; Lang Pengfei

    1986-01-01

    The Monte Carlo method based on the functionization of the performance of detectors and the transformation of values of kinematical variables into ''measured'' ones by means of smearing has been used to program the Monte Carlo simulation of the performance of the Beijing Spectrometer (BES) in FORTRAN language named BESMC. It can be used to investigate the multiplicity, the particle type, and the distribution of four-momentum of the final states of electron-positron collision, and also the response of the BES to these final states. Thus, it provides a measure to examine whether the overall design of the BES is reasonable and to decide the physical topics of the BES

  3. Ion mobility spectrometer with virtual aperture grid

    Pfeifer, Kent B.; Rumpf, Arthur N.

    2010-11-23

    An ion mobility spectrometer does not require a physical aperture grid to prevent premature ion detector response. The last electrodes adjacent to the ion collector (typically the last four or five) have an electrode pitch that is less than the width of the ion swarm and each of the adjacent electrodes is connected to a source of free charge, thereby providing a virtual aperture grid at the end of the drift region that shields the ion collector from the mirror current of the approaching ion swarm. The virtual aperture grid is less complex in assembly and function and is less sensitive to vibrations than the physical aperture grid.

  4. SIMS device with quadrupole mass spectrometer

    Szigethy, D.; Riedel, M.

    1980-01-01

    A versatile secondary ion mass spectrometer (SIMS) has been designed and constructed. The device is applicable for dinamic and static SIMS investigations. The sputtering and ionisation can be studied simultaneously. Oil diffusion pumps and an auxiliary ion-getter pump are used. A commercial ion gun is used in the working chamber. The secondary ion optics assures the preliminary filtering of fast ions, and the collection of sputtered ions for a separate microprobe analysis. The performance of the apparatus is illustrated with examples. (R.J.)

  5. The Triple Axis and SPINS Spectrometers.

    Trevino, S F

    1993-01-01

    In this paper are described the triple axis and spin polarized inelastic neutron scattering (SPINS) spectrometers which are installed at the NIST Cold Neutron Research Facility (CNRF). The general principle of operation of these two instruments is described in sufficient detail to allow the reader to make an informed decision as to their usefulness for his needs. However, it is the intention of the staff at the CNRF to provide the expert resources for their efficient use in any given situation. Thus, this work is not intended as a user manual but rather as a guide into the range of applicability of the two instruments.

  6. An achromatic multipassage magnetic mass spectrometer

    Boulanger, P.; Baril, M.

    1999-01-01

    A design providing achromatic correction to a multipassage magnetic mass spectrometer previously described by the author is presented. The energy spatial dispersion caused by repeated passages in the magnetic prism is corrected by three supplementary mirrors placed in a reinjection loop. From this study one can see that we simultaneously eliminate the energy dispersion term C ΔE/E and the opening angle aberration term C α 2 and we may also eliminate the coupled aberration term C αΔE/E

  7. Time-of-flight mass spectrometer

    Ivanov, M.A.; Kozlov, B.N.; Mamyrin, B.A.; Shmikk, D.V.; Shebelin, V.G.

    1981-01-01

    A time-of-flight mass spectrometer containing a pulsed ion source with an electron gun and two electrodes limiting ionization range, drift space and ion acceptor, is described. To expand functional possibilities, a slot collimator of the gas stream, two quantum generators and two diaphragms for the inlet of quantum generator radiation located on both sides of the ion source, are introduced in the ion source. The above invention enables to study details of the complex interaction process of laser radiation with molecules of the gas stream, which is actual for laser isotope separation

  8. The Omega spectrometer in the West Hall.

    CERN PhotoLab

    1976-01-01

    Inside the hut which sits on top of the superconducting magnet are the TV cameras that observe the particle events occurring in the spark chambers in the magnet gap below. On the background the two beam lines feeding the spectrometer target, for separated hadrons up to 40 GeV, on the right, for 80 GeV electrons, on the left, respectively. The latter strikes a radiator thus sending into Omega tagged photons up to 80 GeV. On the foreground, the two sections of the large gas Cerenkov counter working at atmospheric pressure, used for trigger purpose.

  9. Photoacoustic Soot Spectrometer (PASS) Instrument Handbook

    Dubey, M [Los Alamos National Laboratory; Springston, S [Brookhaven National Laboratory; Koontz, A [Pacific Northwest National Laboratory; Aiken, A [Los Alamos National Laboratory

    2013-01-17

    The photoacoustic soot spectrometer (PASS) measures light absorption by aerosol particles. As the particles pass through a laser beam, the absorbed energy heats the particles and in turn the surrounding air, which sets off a pressure wave that can be detected by a microphone. The PASS instruments deployed by ARM can also simultaneously measure the scattered laser light at three wavelengths and therefore provide a direct measure of the single-scattering albedo. The Operator Manual for the PASS-3100 is included here with the permission of Droplet Measurement Technologies, the instrument’s manufacturer.

  10. The H1 forward muon spectrometer

    Kenyon, I.R.; Phillips, H.; Cronstroem, H.I.; Hedberg, V.; Jacobsson, C.; Joensson, L.; Lohmander, H.; Nyberg, M.; Biddulph, P.; Finnegan, P.; Foster, J.; Gilbert, S.; Hilton, C.; Ibbotson, M.; Mehta, A.; Sutton, P.; Stephens, K.; Thompson, R.

    1993-02-01

    The H1 detector started taking data at the electron- proton collider HERA in the beginning of 1992. In HERA 30 GeV electrons collide with 820 GeV protons giving a strong boost of the centre-of-mass system in the direction of the proton, also called the forward region. For the detection of high momentum muons in this region a muon spectrometer has been constructed, consisting of six drift chamber planes, three either side of a toroidal magnet. A first brief description of the system and its main parameters as well as the principles for track reconstruction and Τ 0 determination is given. (orig.)

  11. Calibration and intercomparison of neutron moderation spectrometers

    Rimpler, A.; Hermanska, J.; Prouza, Z.

    1989-01-01

    Results have been reported of comparative measurements of neutron fields from bare PuBe and Cf sources using multisphere (Bonner) spectrometers. The experiments were carried out by the Institute of Biophysics and Nuclear Medicine at Charles University in Prague and the National Board for Atomic Safety and Radiation Protection in Berlin. Both sides agreed upon uniform measuring conditions and calibration factors thus rendering possible the comparability of the dosimetric parameters which have been determined and verified, respectively, to an accuracy of ± 10%. 20 refs., 10 tabs., 2 figs. (author)

  12. Particulate contamination spectrometer. Volume 1: Technical report

    Schmitt, R. J.; Boyd, B. A.; Linford, R. M. F.

    1975-01-01

    A laser particulate spectrometer (LPS) system was developed to measure the size and speed distributions of particulate (dusts, aerosols, ice particles, etc.) contaminants. Detection of the particulates was achieved by means of light scattering and extinction effects using a single laser beam to cover a size range of 0.8 to 275 microns diameter and a speed range of 0.2 to 20 meter/second. The LPS system was designed to operate in the high vacuum environment of a space simulation chamber with cold shroud temperatures ranging from 77 to 300 K.

  13. Prismatic analyzer concept for neutron spectrometers

    Birk, Jonas O.; Marko, M.; Freeman, P.G.

    2014-01-01

    readily be combined with advanced focussing geometries and with multiplexing instrument designs. We present a combination of simulations and data showing three different energies simultaneously reflected from one analyser. Experiments were performed on a cold triple axis instrument and on a prototype...... inverse geometry Time-of-flight spectrometer installed at PSI, Switzerland, and shows excellent agreement with the predictions. Typical improvements will be 2.0 times finer resolution and a factor of 1.9 in flux gain compared to a focussing Rowland geometry, or of 3.3 times finer resolution and a factor...

  14. AMS, a particle spectrometer in space

    Buenerd, M.; Ohlsson-Malek, F.; Ren, Z.L.; Santos, D.; Thuillier, T.

    1997-01-01

    The Alpha Magnetic Spectrometer (AMS) is a detector designed for extraterrestrial study of anti-matter, matter and dark matter. A precursor flight and on the STS-91 flight of the shuttle is planned to take place on May 1998. AMS will be installed on the International Space Station in January 2002 where it will be operated next, for three to five years. The contributions of the ISN to the project on the shuttle (aerogel threshold Cherenkov counter) as well as the steps to build a RICH detector for AMS on the ISSA are explained here below. (authors)

  15. Dual waveband compact catadioptric imaging spectrometer

    Chrisp, Michael P.

    2012-12-25

    A catadioptric dual waveband imaging spectrometer that covers the visible through short-wave infrared, and the midwave infrared spectral regions, dispersing the visible through shortwave infrared with a zinc selenide grating and midwave infrared with a sapphire prism. The grating and prism are at the cold stop position, enabling the pupil to be split between them. The spectra for both wavebands are focused onto the relevant sections of a single dual waveband detector. Spatial keystone distortion is controlled to less than one tenth of a pixel over the full wavelength range, facilitating the matching of the spectra in the midwave infrared with the shorter wavelength region.

  16. A novel spectrometer for neutrino experiments

    Pasqualini, Laura

    2015-01-01

    The WA104-NESSiE program developed in the context of the CERN Neutrino Platform, includes an innovative spectrometer to measure the charge and the momentum of muons in 0.5-5 GeV/c range. A tracking apparatus with a spatial resolution of 1 mm was designed, to be placed in a magnetized air volume in order to achieve a charge resolution and mis-identification of better than 1% at 1 GeV/c. Preliminary results obtained by detecting cosmic ray muons are reported.

  17. Some physics highlights from the EUROBALL spectrometer

    Korten, W.

    2004-01-01

    The latest generation of large γ-ray spectrometers, such as EUROBALL, has boosted the explorations of nuclei under extreme conditions especially at the limits of angular momentum and at finite temperatures. But the coupling of this instrument to very selective ''ancillary'' devices allows for more and more refined investigations of the third important degree of freedom in contemporary nuclear-structure studies, the isospin. This contribution summarises some of the recent highlights from the physics at EUROBALL obtained in some of the different areas of nuclear-structure research

  18. Calibration of an electron volt neutron spectrometer

    Mayers, J.; Adams, M.A.

    2011-01-01

    The procedure for calibrating the VESUVIO eV neutron spectrometer at the ISIS neutron source is described. VESUVIO is used primarily to measure the momentum distribution n(p) of atoms, by inelastic scattering of very high energy (5-150 eV) neutrons. The results of the calibrations show that measurements of n(p) in atoms with masses lower than 16 amu can be measured with a resolution width ∼25% of the intrinsic peak widths in the current instrument configuration. Some suggestions as to how the instrument resolution could be significantly improved are made.

  19. Bragg rotor spectrometer for tokamak diagnostics

    Barnsley, R.; Evans, K.D.; Peacock, N.J.

    1986-01-01

    This paper discusses high thru'put broad band (1-24 angstrom) x-ray spectrometer having absolute calibration for wavelength and intensity and demonstrated on the DITE tokamak. This instrument has a self-contained vacuum system which allows full spatial scans of the DITE plasma. Data acquisition and drive mechanism for the rotor and filter selection are operated remotely from a SADA. Results are presented of fast spectral surveys and λ-lock time-evolution of impurity emission during neutral beam injection. Spatial scans of the absolute impurity concentrations are derived

  20. Fast neutron spectrometer with pulse shape discrimination

    Verbitsky, S.S.

    1978-01-01

    A fast neutron spectrometer with a stilbene single crystal designed to operate at high pulsed count rate has been described. Making use of identification and rejection of events, accompanied by pile-up, allowed to increase permissible count rates by an order of magnitude. The results of energy dependence of signal amplitude and shape relative anisotropy in stilbene in the range 4-10 and 2-8 MeV respectively have been presented. Taking into account anisotropy of the detector-scintillation properties allowed to improve particle discrimination. (Auth.)

  1. Micro-optical-mechanical system photoacoustic spectrometer

    Kotovsky, Jack; Benett, William J.; Tooker, Angela C.; Alameda, Jennifer B.

    2013-01-01

    All-optical photoacoustic spectrometer sensing systems (PASS system) and methods include all the hardware needed to analyze the presence of a large variety of materials (solid, liquid and gas). Some of the all-optical PASS systems require only two optical-fibers to communicate with the opto-electronic power and readout systems that exist outside of the material environment. Methods for improving the signal-to-noise are provided and enable mirco-scale systems and methods for operating such systems.

  2. A dilepton spectrometer project for SIS

    Meritet, L.

    1991-01-01

    An experimental project is presented to study e + e - pairs production in nucleus-nucleus collisions at GSI. Dileptons appear to be a clean probe to investigate in medium properties of nuclear form factors, baryon excitations (Δ) and mesons (π-dispersion relation; ρ-form factor) at high nuclear matter densities. The design of the detector system will be based on the experience obtained with the DLS-spectrometer at LBL and other dilepton detector systems in operation at high energy facilities. The project includes a fast electron trigger provided by a ring imaging Cherenkov detector with a segmented photomultiplier array. (author) 14 refs., 5 figs

  3. Electro-optic imaging Fourier transform spectrometer

    Chao, Tien-Hsin (Inventor); Znod, Hanying (Inventor)

    2009-01-01

    An Electro-Optic Imaging Fourier Transform Spectrometer (EOIFTS) for Hyperspectral Imaging is described. The EOIFTS includes an input polarizer, an output polarizer, and a plurality of birefringent phase elements. The relative orientations of the polarizers and birefringent phase elements can be changed mechanically or via a controller, using ferroelectric liquid crystals, to substantially measure the spectral Fourier components of light propagating through the EIOFTS. When achromatic switches are used as an integral part of the birefringent phase elements, the EIOFTS becomes suitable for broadband applications, with over 1 micron infrared bandwidth.

  4. Computerized mass spectrometer data system at LLL

    Friesen, R.D.; Dupzyk, R.J.

    1976-01-01

    The data systems on the three mass spectrometers at LLL are computer-controlled, pulse-counting systems synchronized to a repeatedly swept magnetic field. The data are accumulated in the memory of the computer or in a Nuclear Data ND 180 in a multi-scaler mode of operation. This mode of data acquisition allows a continuous check of the background stability and makes tune-up easier. But the main benefit is a reduction in the required ion emission rate stability. By the use of standards to set the system dead time, we have been able to utilize the sensitivity of a pulse counting system without the expense of exotic equipment

  5. Mass spectrometer data system at LLL

    Friesen, R.D.

    1975-01-01

    The data systems on the three mass spectrometers at LLL are computer-controlled, pulse-counting systems synchronized to a repeatedly-swept magnetic field. The data are accumulated in the memory of the computer or in a Nuclear Data ND 180 in a multi-scaler mode of operation. This mode of sweeping allows a continuous check of the background stability and makes tune-up easier. But the main benefit is a reduction in the required ion emission rate stability. By the use of standards to set the system dead time, we have been able to utilize the sensitivity of a pulse counting system without the expense of exotic equipment

  6. MPS [Multiparticle Spectrometer] data acquisition software system

    Saulys, A.C.; Etkin, A.; Foley, K.J.

    1989-01-01

    A description of the software for a FASTBUS based data acquisition system in use at the Brookhaven National Laboratory Multiparticle Spectrometer is presented. Data reading and formatting is done by the SLAC Scanner Processors (SSP's) resident in the FASTBUS system. A multiprocess software system on VAX computers is used to communicate with the SSP's, record the data, and monitor on-line the progress of high energy and heavy ion experiments. The structure and the performance of this system are discussed. 4 refs., 1 fig

  7. Recent progress in the chopper spectrometer, INC

    Itoh, Shinichi; Arai, Masatoshi; Kawai, Masayoshi

    2001-01-01

    A guide tube comprising supermirrors, of which the critical wavenumber is three times as large as that of natural nickel, was installed in the primary flight path of the chopper spectrometer, INC, at KENS. Also, the characteristics of the ambient-temperature H 2 O moderator, which INC is facing, was changed by renewal construction of the neutron source at KENS. We discuss here an improvement in the performance of INC by a comparison with the previous performance. We also report on the development on a goniometer for single-crystal experiments at low temperatures. (author)

  8. Lead Slowing Down Spectrometer Status Report

    Warren, Glen A.; Anderson, Kevin K.; Bonebrake, Eric; Casella, Andrew M.; Danon, Yaron; Devlin, M.; Gavron, Victor A.; Haight, R.C.; Imel, G.R.; Kulisek, Jonathan A.; O'Donnell, J.M.; Weltz, Adam

    2012-01-01

    This report documents the progress that has been completed in the first half of FY2012 in the MPACT-funded Lead Slowing Down Spectrometer project. Significant progress has been made on the algorithm development. We have an improve understanding of the experimental responses in LSDS for fuel-related material. The calibration of the ultra-depleted uranium foils was completed, but the results are inconsistent from measurement to measurement. Future work includes developing a conceptual model of an LSDS system to assay plutonium in used fuel, improving agreement between simulations and measurement, design of a thorium fission chamber, and evaluation of additional detector techniques.

  9. Albuquerque/Middle Rio Grande Urban Waters Viewer

    These data have been compiled in support of the Middle Rio Grande/Albuquerque Urban Waters Partnership for the region including Albuquerque, New Mexico.The Middle Rio Grande/Albuquerque Urban Waters Federal Partnership is co-chaired by the U.S. Dept. of Housing and Urban Development and the U.S. Environmental Protection Agency. There are also a number of other federal agencies engaged in projects with Tribal, State, and local officials, and community stakeholders. Like many western river ecosystems, the Middle Rio Grande faces numerous challenges in balancing competing needs within a finite water supply and other resource constrains. Historical practices by our ancestors and immigrants to the Middle Rio Grande have established the conditions that we have inherited. Long-term drought exacerbated by climate change is changing conditions that affect natural and human communities as we strive to improve our precious Rio Grande.The Middle Rio Grande/Albuquerque Urban Waters Federal Partnership will reconnect our urban communities, particularly those that are overburdened or economically distressed, with the waterway by improving coordination among federal agencies and collaborating with community-led revitalization efforts. Our projects will improve our community water systems and promote their economic, environmental and social benefits. Specifically, the Middle Rio Grande/Albuquerque Urban Waters Federal Partnership will support the development of the Valle de Oro

  10. Grand Fir Nutrient Management in the Inland Northwestern USA

    Dennis R. Parent

    2016-11-01

    Full Text Available Grand fir (Abies grandis (Douglas ex D. Don Lindley is widely distributed in the moist forests of the Inland Northwest. It has high potential productivity, its growth being nearly equal to western white pine, the most productive species in the region. There are large standing volumes of grand fir in the region. Nutritionally, the species has higher foliage cation concentrations than associated conifers, especially potassium (K and calcium (Ca. In contrast, it has lower nitrogen (N foliage concentrations, which creates favorable nutrient balance on N-limited sites. Despite concentration differences, grand fir stores proportionally more nutrients per tree than associated species because of greater crown biomass. Although few fertilization trials have examined grand fir specifically, its response is inferred from its occurrence in many monitored mixed conifer stands. Fertilization trials including grand fir either as a major or minor component show that it has a strong diameter and height growth response ranging from 15% to 50% depending in part on site moisture availability and soil geology. Grand fir tends to have a longer response duration than other inland conifers. When executed concurrently with thinning, fertilization often increases the total response. Late rotation application of N provides solid investment returns in carefully selected stands. Although there are still challenges with the post-fertilization effects on tree mortality, grand fir will continue to be an important species with good economic values and beneficial responses to fertilization and nutrient management.

  11. Development of triple axis neutron spectrometer (Paper No. 24)

    Pal, B.C.; Wadhwa, N.R.; Goveas, S.H.

    1987-02-01

    The triple axis neutron spectrometers are the basic instruments intended for use with neutron beams from reactors. Various types of spectrometers, each devoted to different kinds of measurement can be designed and manufactured, once a prototype having all the attributes of a versatile instrument is designed and developed. With the view to achieving self reliance in this field, Central Workshops of Bhabha Atomic Research Centre (BARC), Bombay designed and developed a prototype of triple axis spectrometer meeting the specifications prepared by Nuclear Physics Division of BARC . This spectrometer, with a moving wedge system was successfully manufactured and installed at 'DHRUVA'. Another version of this spectrometer, called the 'Polarised Neutron Spectrometer' was also built and exported to South Korea and installed at Korea Advanced Energy Research Institute, Seoul. This paper deals with basic concept, development of design, engineering of mechanical assemblies, the manufacturing approach and problems encountered during manufacture. (author). 3 figs

  12. Chirped Pulse Spectrometer Operating at 200 GHz

    Hindle, Francis; Bray, Cédric; Hickson, Kevin; Fontanari, Daniele; Mouelhi, Meriem; Cuisset, Arnaud; Mouret, Gaël; Bocquet, Robin

    2018-01-01

    The combination of electronic sources operating at high frequencies and modern microwave instrumentation has enabled the recent development of chirped pulse spectrometers for the millimetre and THz bands. This type of instrument can operate at high resolution which is particularly suited to gas-phase rotational spectroscopy. The construction of a chirped pulse spectrometer operating at 200 GHz is described in detail while attention is paid to the phase stability and the data accumulation over many cycles. Validation using carbonyl sulphide has allowed the detection limit of the instrument to be established as function of the accumulation. A large number of OCS transitions were identified using a 10-GHz chirped pulse and include the six most abundant isotopologues, the weakest line corresponding to the fundamental R(17) transition of 16O13C33S with a line strength of 4.3 × 10-26 cm-1/(molecule cm-2). The linearity of the system response for different degrees of data accumulation and transition line strength was confirmed over four orders of magnitudes. A simple analysis of the time-domain data was demonstrated to provide the line-broadening coefficient without the need for conversion by a Fourier transform. Finally, the pulse duration is discussed and optimal values are given for both Doppler-limited and collisional regimes.

  13. Mass spectrometer with two ion sources

    Glickman, L.G.; Mit', A.G.

    2002-01-01

    Static mass spectrometer with mid-plane near which ions are moving is considered in this article. Two ion sources are used, their exit slits are perpendicular to the mid-plane. The simple method of the replacement of source is offered. Two concave two-electrode transaxial mirrors with two-plate electrodes are used for this aim. The mid-plane of these mirrors coincides with the mid-plane of the device. The exit slit of each source is located in the principal plane of the object space. The principal planes of the image space of the both mirrors coincide. The images of the exit slits of the sources are in these planes and coincide too. We used the mirrors making stigmatic images with the magnification one to one, in which the dispersion on energy and spherical aberrations of the second order are equal to zero. These images are the objects on which the ion-optical system of the mass spectrometer is tuned. When you choose one from two ion sources it is enough to switch the corresponding mirror

  14. The Calibration Home Base for Imaging Spectrometers

    Johannes Felix Simon Brachmann

    2016-08-01

    Full Text Available The Calibration Home Base (CHB is an optical laboratory designed for the calibration of imaging spectrometers for the VNIR/SWIR wavelength range. Radiometric, spectral and geometric calibration as well as the characterization of sensor signal dependency on polarization are realized in a precise and highly automated fashion. This allows to carry out a wide range of time consuming measurements in an ecient way. The implementation of ISO 9001 standards in all procedures ensures a traceable quality of results. Spectral measurements in the wavelength range 380–1000 nm are performed to a wavelength uncertainty of +- 0.1 nm, while an uncertainty of +-0.2 nm is reached in the wavelength range 1000 – 2500 nm. Geometric measurements are performed at increments of 1.7 µrad across track and 7.6 µrad along track. Radiometric measurements reach an absolute uncertainty of +-3% (k=1. Sensor artifacts, such as caused by stray light will be characterizable and correctable in the near future. For now, the CHB is suitable for the characterization of pushbroom sensors, spectrometers and cameras. However, it is planned to extend the CHBs capabilities in the near future such that snapshot hyperspectral imagers can be characterized as well. The calibration services of the CHB are open to third party customers from research institutes as well as industry.

  15. Performance Validation of the ATLAS Muon Spectrometer

    Mair, Katharina

    ATLAS (A Toroidal LHC ApparatuS) is a general-purpose experiment for the future Large Hadron Collider (LHC) at CERN, which is scheduled to begin operation in the year 2007, providing experiments with proton-proton collisions. The center-of-mass energy of 14TeV and the design luminosity of 1034 cm−2s−1 will allow to explore many new aspects of fundamental physics. The ATLAS Muon Spectrometer aims at a momentum resolution better than 10% for transverse momentum values ranging from pT = 6 GeV to pT = 1TeV. Precision tracking will be performed by Ar-CO2-gas filled Monitored Drift Tube chambers (MDTs), with a single wire resolution of < 100 μm. In total, about 1 200 chambers, arranged in a large structure, will allow muon track measurements over distances up to 15m in a magnetic field of 0.5 T. Given the large size of the spectrometer it is impossible to keep the shape of the muon chambers and their positions stable within the requested tracking accuracy of 50 μm. Therefore the concept of an optical alig...

  16. Analog and digital dividers for mass spectrometers

    Osipov, A.K.

    1980-01-01

    Errors of four different types of stress dividers used in statical mass-spectrometers for determination of mass number by accelerating stress are analyzed. The simplest flowsheet of the analog divider comprises operation amplifier, in the chain of the negative feedback of which a multiplication device on differential cascade is switched- in. This analog divider has high sensitivity to temperature and high error approximately 5%. Application of the multiplier on differential cascade with normalization permits to increase temperature stability and decrease the error up to 1%. Another type of the analog divider is a logarithmic divider the error of which is constant within the whole operation range and it constitutes 1-5%. The digital divider with a digital-analog transformer (DAT) has the error of +-0.015% which is determined by the error of detectors and resistance of keys in the locked state. Considered is the design of a divider based on transformation of the inlet stress into the time period. The error of the divider is determined in this case mainly by stress of the zero shift of the operation amplifier (it should be compensated) and relative threshold stability of the comparator triggering which equals (2-3)x10 -4 . It is noted that the divider with DAT application and the divider with the use of stress transformation within the time period are most perspective ones for statical mass-spectrometers [ru

  17. Local tracking in the ATLAS muon spectrometer

    Primor, David; Mikenberg, Giora

    2007-01-01

    The LHC, the largest hadron collider accelerator ever built, presents new challenges for scientists and engineers. With the anticipated luminosity of the LHC, it is expected to have as many as one billion total collisions per second, of which at most 10 to 100 per second might be of potential scientific interest. One of the two major, general-purpose experiments at LHC is called ATLAS. Since muons are one of the important signs of new physics, the need of their detection has lead to the construction of a stand- alone Muon Spectrometer. This system is located in a high radiation background environment (mostly neutrons and photons) which makes the muon tracking a very challenging task. The Muon Spectrometer consists of two types of precision chambers, the Monitor Drift Tube (MDT) chambers, and the Cathode Strip Chambers (CSC). In order to detect the muon and estimate its track parameters, it is very important to detect and precisely estimate its local tracks within the CSC and MDT chambers. Using advanced signa...

  18. The ALICE Dimuon Spectrometer High Level Trigger

    Becker, B; Cicalo, Corrado; Das, Indranil; de Vaux, Gareth; Fearick, Roger; Lindenstruth, Volker; Marras, Davide; Sanyal, Abhijit; Siddhanta, Sabyasachi; Staley, Florent; Steinbeck, Timm; Szostak, Artur; Usai, Gianluca; Vilakazi, Zeblon

    2009-01-01

    The ALICE Dimuon Spectrometer High Level Trigger (dHLT) is an on-line processing stage whose primary function is to select interesting events that contain distinct physics signals from heavy resonance decays such as J/psi and Gamma particles, amidst unwanted background events. It forms part of the High Level Trigger of the ALICE experiment, whose goal is to reduce the large data rate of about 25 GB/s from the ALICE detectors by an order of magnitude, without loosing interesting physics events. The dHLT has been implemented as a software trigger within a high performance and fault tolerant data transportation framework, which is run on a large cluster of commodity compute nodes. To reach the required processing speeds, the system is built as a concurrent system with a hierarchy of processing steps. The main algorithms perform partial event reconstruction, starting with hit reconstruction on the level of the raw data received from the spectrometer. Then a tracking algorithm finds track candidates from the recon...

  19. Development of a junction β - spectrometer

    Hashizume, A.

    1966-01-01

    A β spectrometry unit using junctions of the silicon surface barrier type has been built. The resolving power of this spectrometer has been studied as well as the influence of a certain number of parameters (temperature, polarization voltage) on its characteristics. A study with this unit of some internal conversion electron spectra ( 113 Sn, 137 Cs, 139 Ce, 195 Au, 207 Bi) has led both to a determination of its characteristics and of an energy calibration, and to the determination of certain internal conversion ratios of these radionuclides. This spectrometer was then used for a study of (5-spectra in particular that of 35 S and 14 C. The calculations and corrections required for the setting-up of Kuries representation are described. The programmes required for the carrying-out of these calculations with an I.B.M. computer are given. It has been verified that Kuries representation for 14 C above 90 keV is in fact linear. The non-linear aspect observed by certain authors is probably due to the 'quality' of the sources used. The Fierz interference term has been determined. The maximum β energies found are respectively: 167 ± 1 keV for 35 S and 155 ± 2 keV for 14 C. (author) [fr

  20. New mass spectrometers for hydrogen isotope analyses

    Chastagner, P.; Daves, H.L.; Hess, W.B.

    1981-01-01

    Two advanced mass spectrometers for the accurate analysis of mixtures of the hydrogen isotopes are being evaluated by Du Pont personnel at the Savannah River Laboratory. One is a large double-focusing instrument with a resolution of 2000 at mass 4, an abundance sensitivity of > 100,000 for the HT-D 2 doublet, and a sophisticated electronic control and data collection system. The second is a smaller, simpler, stigmatic-focusing instrument in which exceptionally high ion intensities (> 1 x 10 -9 A) result in high signal to noise ratios. A containment facility with sample inlet systems and a standard distribution system was built to permit testing with tritium mixtures. The characteristics of the mass spectrometers under a variety of operating conditions will be presented. Factors to be discussed include: sample equilibration and its elimination; linearity; trimer formation; gas interference; stability; signal to noise ratio; mass discrimination; and anticipated precision and accu sublimed molybdenum collector of Converter No. 262; and (3) demonstration of tungsten CVD onto molybdenum flange using a reuseable graphite mandrel

  1. Calibrated infrared ground/air radiometric spectrometer

    Silk, J. K.; Schildkraut, Elliot Robert; Bauldree, Russell S.; Goodrich, Shawn M.

    1996-06-01

    The calibrated infrared ground/air radiometric spectrometer (CIGARS) is a new high performance, multi-purpose, multi- platform Fourier transform spectrometer (FPS) sensor. It covers the waveband from 0.2 to 12 micrometer, has spectral resolution as fine as 0.3 cm-1, and records over 100 spectra per second. Two CIGARS units are being used for observations of target signatures in the air or on the ground from fixed or moving platforms, including high performance jet aircraft. In this paper we describe the characteristics and capabilities of the CIGARS sensor, which uses four interchangeable detector modules (Si, InGaAs, InSb, and HgCdTe) and two optics modules, with internal calibration. The data recording electronics support observations of transient events, even without precise information on the timing of the event. We present test and calibration data on the sensitivity, spectral resolution, stability, and spectral rate of CIGARS, and examples of in- flight observations of real targets. We also discuss plans for adapting CIGARS for imaging spectroscopy observations, with simultaneous spectral and spatial data, by replacing the existing detectors with a focal plane array (FPA).

  2. New imaging spectrometer for auroral research

    Rairden, R.; Swenson, G.

    1994-01-01

    A Loral 1024 x 1024 CCD array with 15-micron pixels has been incorporated as the focal plane detector in a new imaging spectrometer for auroral research. The large format low-noise CCD provides excellent dynamic range and signal to noise characteristics with image integration times on the order of 60 seconds using f/1.4 camera optics. Further signal enhancement is achieved through on-CCD pixel binning. In the nominal binned mode the instrument wavelength resolution varies from 15 to 30 angstrom across the 5000 to 8600 angstrom spectral range. Images are acquired and stored digitally on a Macintosh computer. This instrument was operated at a field site in Godhavn, Greenland during the past two winters (1993, 1994) to measure the altitude distribution of the various spectral emissions within auroral arcs. The height resolution on an auroral feature 300 km distant is ∼1 km. Examples of these measurements are presented here in snapshot and summary image formats illustrating the wealth of quantitative information provided by this new imaging spectrometer

  3. Basics of spectroscopic instruments. Hardware of NMR spectrometer

    Sato, Hajime

    2009-01-01

    NMR is a powerful tool for structure analysis of small molecules, natural products, biological macromolecules, synthesized polymers, samples from material science and so on. Magnetic Resonance Imaging (MRI) is applicable to plants and animals Because most of NMR experiments can be done by an automation mode, one can forget hardware of NMR spectrometers. It would be good to understand features and performance of NMR spectrometers. Here I present hardware of a modern NMR spectrometer which is fully equipped with digital technology. (author)

  4. High resolution 14 MeV neutron spectrometer

    Pillon, M.

    1986-01-01

    A neutron spectrometer, based both on the track position identification and the energy measurement of recoiling protons from a hydrogenous radiator is proposed. The expected performance limits of this spectrometer with regard to energy resolution (deltaE/E), efficiency (epsilon) and counting rate are evaluated in five different configurations. The results show the possibility of deriving an optimized spectrometer design for applications on large fusion devices such as JET and NET with an energy resolution up 1% at 14 MeV

  5. MAGNETIC SPECTROMETER DESIGN FOR ELECTRON SCATTERING ABOVE 1 Bev

    Schopper, H.

    1963-06-15

    Design considerations are discussed for magnetic spectrometer electron scattering investigations with the higher energy (above 1 Bev) electron sources which are being developed. The spectrometers are to be used to discriminate between elastic and inelastic processes. A momentum resolution of the order of one per cent is required for these experiments. Various spectrometers are compared according to their optical properties and the number of magnets they consist of. (R.E.U.)

  6. Proton decay: Numerical simulations confront grand unification

    Brower, R.C.; Maturana, G.; Giles, R.C.; Moriarty, K.J.M.; Samuel, S.

    1985-01-01

    The Grand Unified Theories of the electromagnetic, weak and strong interactions constitute a far reaching attempt to synthesize our knowledge of theoretical particle physics into a consistent and compelling whole. Unfortunately, many quantitative predictions of such unified theories are sensitive to the analytically intractible effects of the strong subnuclear theory (Quantum Chromodynamics or QCD). The consequence is that even ambitious experimental programs exploring weak and super-weak interaction effects often fail to give definitive theoretical tests. This paper describes large-scale calculations on a supercomputer which can help to overcome this gap between theoretical predictions and experimental results. Our focus here is on proton decay, though the methods described are useful for many weak processes. The basic algorithms for the numerical simulation of QCD are well known. We will discuss the advantages and challenges of applying these methods to weak transitions. The algorithms require a very large data base with regular data flow and are natural candidates for vectorization. Also, 32-bit floating point arithmetic is adequate. Thus they are most naturally approached using a supercomputer alone or in combination with a dedicated special purpose processor. (orig.)

  7. Coordinating the Atlantis Grand Opening Event

    Smith, Abigail Allaine

    2013-01-01

    While working as the marketing intern for Kennedy Space Center's (KSC) Center Planning and Development Directorate (CPD), I was given the opportunity not only to learn new skills and expand my work experience under the powerful influence of NASA, but I also was given the opportunity to prove that I am an individual capable of contributing to the KSC team. My main responsibility while working in CPD was to organize and run a booth that represented the entire directorate at the Grand Opening of the Shuttle Atlantis exhibit during the weekend of June 28-30. This event was important for CPD because as a Directorate that markets KSC's facilities, technical capabilities and technologies to potential partners, it is important to attend all events and use them to gain an understanding of our audience. Although we catered mostly to the general public during this event, it was still important to reach out to the larger space enthusiast community and let them know about KSC's future plans to become a multi-user spaceport and that teclmology is still being developed.

  8. The grand descent has begun for CMS

    2006-01-01

    Until recently, the CMS experimental cavern looked relatively empty; its detector was assembled entirely at ground level, to be lowered underground in 15 sections. On 2 November, the first hadronic forward calorimeter led the way with a grand descent. The first section of the CMS detector (centre of photo) arriving from the vertical shaft, viewed from the cavern floor. There is something unusual about the construction of the CMS detector. Instead of being built in the experimental cavern, like all the other detectors in the LHC experiments, it was constructed at ground level. This was to allow for easy access during the assembly of the detector and to minimise the size of the excavated cavern. The slightly nerve-wracking task of lowering it safely into the cavern in separate sections came after the complete detector was successfully tested with a magnetic field at ground level. In the early morning of 2 November, the first section of the CMS detector began its eagerly awaited descent into the underground ca...

  9. Local grand unification in the heterotic landscape

    Schmidt, Jonas

    2009-06-01

    We consider the possibility that the unification of the electroweak interactions and the strong force arises from string theory, at energies significantly lower than the string scale. As a tool, an effective grand unified field theory in six dimensions is derived from an anisotropic orbifold compactification of the heterotic string. It is explicitly shown that all anomalies cancel in the model, though anomalous Abelian gauge symmetries are present locally at the boundary singularities. In the supersymmetric vacuum additional interactions arise from higher-dimensional operators. We develop methods that relate the couplings of the effective theory to the location of the vacuum, and find that unbroken discrete symmetries play an important role for the phenomenology of orbifold models. An efficient algorithm for the calculation of the superpotential to arbitrary order is developed, based on symmetry arguments. We furthermore present a correspondence between bulk fields of the orbifold model in six dimensions, and the moduli fields that arise from compactifying four internal dimensions on a manifold with non-trivial gauge background. (orig.)

  10. Gauge hierarchy problem in grand unified theories

    Alhendi, H.A.A.

    1982-01-01

    In grand unification schemes, several mass scales are to be introduced, with some of them much larger than all the others, to cope with experimental observations, in which elementary particles of higher masses require higher energy to observe them than elementary particles of lower masses. There have been controversial arguments in the literature on such hierarchical scale structure, when radiative corrections are taken into account. It has been asserted that the gauge hierarchy depends on the choice of the subtraction point (in the classical field space), of the four-point function at zero external momentum. It also has been asserted that the gauge hierarchy problem whenever it is possible to be maintained in one sector of particles, it also is possible to be maintained in the other sectors. These two problems have been studied in a prototype model, namely an 0(3)-model with two triplets of real scalar Higgs fields. Our analysis shows that, within ordinary perturbation theory, none of these two problems is quite correct

  11. Integrated telemedicine workstation for intercontinental grand rounds

    Willis, Charles E.; Leckie, Robert G.; Brink, Linda; Goeringer, Fred

    1995-04-01

    The Telemedicine Spacebridge to Moscow was a series of intercontinental sessions sponsored jointly by NASA and the Moscow Academy of Medicine. To improve the quality of medical images presented, the MDIS Project developed a workstation for acquisition, storage, and interactive display of radiology and pathology images. The workstation was based on a Macintosh IIfx platform with a laser digitizer for radiographs and video capture capability for microscope images. Images were transmitted via the Russian Lyoutch Satellite which had only a single video channel available and no high speed data channels. Two workstations were configured -- one for use at the Uniformed Services University of Health Sciences in Bethesda, MD. and the other for use at the Hospital of the Interior in Moscow, Russia. The two workstations were used may times during 16 sessions. As clinicians used the systems, we modified the original configuration to improve interactive use. This project demonstrated that numerous acquisition and output devices could be brought together in a single interactive workstation. The video images were satisfactory for remote consultation in a grand rounds format.

  12. Grand unification in the projective plane

    Hebecker, A.

    2004-01-01

    A 6-dimensional grand unified theory with the compact space having the topology of a real projective plane, i.e., a 2-sphere with opposite points identified, is considered. The space is locally flat except for two conical singularities where the curvature is concentrated. One supersymmetry is preserved in the effective 4d theory. The unified gauge symmetry, for example SU(5), is broken only by the non-trivial global topology. In contrast to the Hosotani mechanism, no adjoint Wilson-line modulus associated with this breaking appears. Since, locally, SU(5) remains a good symmetry everywhere, no UV-sensitive threshold corrections arise and SU(5)-violating local operators are forbidden. Doublet-triplet splitting can be addressed in the context of a 6d N=2 super Yang-Mills theory with gauge group SU(6). If this symmetry is first broken to SU(5) at a fixed point and then further reduced to the standard model group in the above non-local way, the two light Higgs doublets of the MSSM are predicted by the group-theoretical and geometrical structure of the model. (author)

  13. y las grandes ciudades: 1970-2004

    Adrián de León Arias

    2008-01-01

    Full Text Available El cambio regional en las manufacturas mexicanas a partir de la década de 1980 se ha caracterizado por el rápido crecimiento del empleo y la producción en la frontera norte del país y la pérdida de participación de ellos en las grandes ciudades. En este artículo se analiza y evalúa este cambio regional en términos de la dinámica de la productividad laboral y factorial total para ambas configuraciones espaciales, presentando cálculos de productividad para éstas de 1970 a 2004, estimados a partir de la información censal. Los resultados sugieren que mientras el empleo ha crecido en magnitud mucho más rápido en la frontera norte, esta dinámica se ha generado con bajos niveles en crecimiento de la productividad, al menos hasta fechas recientes, por lo que el cambio regional estimulado por la apertura comercial hasta 2004 no parece haber facilitado un crecimiento económico más acelerado para México

  14. Local grand unification in the heterotic landscape

    Schmidt, Jonas

    2009-07-15

    We consider the possibility that the unification of the electroweak interactions and the strong force arises from string theory, at energies significantly lower than the string scale. As a tool, an effective grand unified field theory in six dimensions is derived from an anisotropic orbifold compactification of the heterotic string. It is explicitly shown that all anomalies cancel in the model, though anomalous Abelian gauge symmetries are present locally at the boundary singularities. In the supersymmetric vacuum additional interactions arise from higher-dimensional operators. We develop methods that relate the couplings of the effective theory to the location of the vacuum, and find that unbroken discrete symmetries play an important role for the phenomenology of orbifold models. An efficient algorithm for the calculation of the superpotential to arbitrary order is developed, based on symmetry arguments. We furthermore present a correspondence between bulk fields of the orbifold model in six dimensions, and the moduli fields that arise from compactifying four internal dimensions on a manifold with non-trivial gauge background. (orig.)

  15. Constraints on grand unified superstring theories

    Ellis, J.; Lopez, J.L.; Nanopoulos, D.V.; Houston Advanced Research Center

    1990-01-01

    We evaluate some constraints on the construction of grand unified superstring theories (GUSTs) using higher level Kac-Moody algebras on the world-sheet. In the most general formulation of the heterotic string in four dimensions, an analysis of the basic GUST model-building constraints, including a realistic hidden gauge group, reveals that there are no E 6 models and any SO(10) models can only exist at level-5. Also, any such SU(5) models can exist only for levels 4≤k≤19. These SO(10) and SU(5) models risk having many large, massless, phenomenologically troublesome representations. We also show that with a suitable hidden sector gauge group, it is possible to avoid free light fractionally charged particles, which are endemic to string derived models. We list all such groups and their representations for the flipped SU(5)xU(1) model. We conclude that a sufficiently binding hidden sector gauge group becomes a basic model-building constraint. (orig.)

  16. A unified grand tour of theoretical physics

    Griffiths, J

    2002-01-01

    Anyone offering a grand tour is faced with several options. Should they concentrate on what may be considered to be essential features, or should they attempt to present a brief glimpse of almost everything? The present offering is a compromise between these two extremes. The area considered - theoretical physics - is now such a vast subject that some kind of compromise is essential. Indeed, the field is now so wide that few could even attempt to review it in a single-authored work. My task here is to assess how well this book has succeeded in its main aim of providing a unified (though introductory) tour of this subject. Constrained within a single volume, this is clearly not an updated Landau-Lifschitz. It cannot be expected to take any particular topic to the level of recent research. Nevertheless, it does seem to cover the broad range of essential topics which now constitute the subject. It starts (most appropriately in my opinion) with geometry. It then covers classical physics, general relativity and qu...

  17. Optimization of time-correlated single photon counting spectrometer

    Zhang Xiufeng; Du Haiying; Sun Jinsheng

    2011-01-01

    The paper proposes a performance improving scheme for the conventional time-correlated single photon counting spectrometer and develops a high speed data acquisition card based on PCI bus and FPGA technologies. The card is used to replace the multi-channel analyzer to improve the capability and decrease the volume of the spectrometer. The process of operation is introduced along with the integration of the spectrometer system. Many standard samples are measured. The experimental results show that the sensitivity of the spectrometer is single photon counting, and the time resolution of fluorescence lifetime measurement can be picosecond level. The instrument could measure the time-resolved spectroscopy. (authors)

  18. High intensity line source for x-ray spectrometer calibration

    Thoe, R.S.

    1986-06-01

    A high intensity electron-impact x-ray source using a one-dimensional Pierce lens has been built for the purpose of calibrating a bent crystal x-ray spectrometer. This source focuses up to 100 mA of 20-keV electrons to a line on a liquid-cooled anode. The line (which can serve as a virtual slit for the spectrometer) measures approximately 800 μ x 2 cm. The source is portable and therefore adaptable to numerous types of spectrometer applications. One particular application, the calibration of a high resolution (r = 10 4 ) time-resolved cyrstal spectrometer, will be discussed in detail

  19. Imaging spectrometer using a liquid crystal tunable filter

    Chrien, Thomas G.; Chovit, Christopher; Miller, Peter J.

    1993-09-01

    A demonstration imaging spectrometer using a liquid crystal tunable filter (LCTF) was built and tested on a hot air balloon platform. The LCTF is a tunable polarization interference or Lyot filter. The LCTF enables a small, light weight, low power, band sequential imaging spectrometer design. An overview of the prototype system is given along with a description of balloon experiment results. System model performance predictions are given for a future LCTF based imaging spectrometer design. System design considerations of LCTF imaging spectrometers are discussed.

  20. BIS-2 spectrometer for search and investigation of narrow resonances

    Aleev, A.N.; Aref'ev, V.A.; Balandin, V.P.

    1989-01-01

    The configuration and main characteristics of the BIS-2 spectrometer are described. The spectrometer was intended to search for and to investigate charmed particles and narrow resonances produced in neutron-nucleus interactions. It was placed on a neutron beam of the Serpukhov accelerator. The Monte-Carlo simulated and experimentally measured characteristics of individual elements and the spectrometer as a whole are described. A brief review of the principal results based on the analysis of more than 10 7 neutron-nucleus interactions registered by means of the BIS-2 spectrometer is given. 34 refs.; 8 figs.; 5 tabs

  1. Polarized neutron spectrometer for inelastic experiments at J-PARC

    Yokoo Tetsuya

    2015-01-01

    Full Text Available Construction of the newly developed polarization analysis neutron chopper spectrometer (POLANO commenced in the Japan Proton Accelerator Research Complex (J-PARC, Materials and Life Science Experimental Facility (MLF. The POLANO is a direct geometry chopper spectrometer with neutron polarization analysis capability. In the suite of inelastic spectrometers, six instruments are now in operation. POLANO will be the only spectrometer dedicated to polarization analysis experiments. The primary phase of the construction will be completed by 2014 with beam commissioning scheduled for 2015.

  2. NQR spectrometer controlled by a computer

    Stoican, Ovidiu

    2002-01-01

    Nuclear quadrupole resonance (NQR) is one of the sensitive methods for studying physical and chemical properties of a substance, such as chemical composition, molecular structure, molecular motion and electronic environment. The specifications of the research project require the use of a nuclear quadrupole resonance spectrometer. Design and performances of a pulsed nuclear quadrupole resonance spectrometer prototype covering the range 1-10 MHz are presented. The pulsed NQR method offers considerably higher sensitivity than either the marginal oscillator or super-regenerative methods. Strong echoes are often observed directly with an oscilloscope or a simple receiver. The method allows us to observe two signal categories: free induction decay (fid) and echoes. The block diagram of the pulsed nuclear quadrupole resonance spectrometer is shown. All operations performed by the spectrometer are controlled by a computer. The scanning frequency range, amplitude and width of the RF pulse, additional magnetic field and sample temperature can be controlled by the software. Also it is possible to improve the signal-to-noise ratio using digital filtering applied to the data stored. Automatic operation eliminates operator skill and uncertainty of manual operation. The NQR spectrometer control software is a stand alone executable file, runs on Windows 95/98 platform and does not require the existence of another software package. A graphical interface allows to user an easy control over the spectrometer operations. All measured parameters by the control system interface are saved in the standard data files and can be processed further. The design is readily adaptable for other applications. The sample is contained within an aluminum cylindrical case. The upper end cap of the case can be removed and it allows introducing the sample. On the upper end cap RF and main temperature sensor connector are placed. On the internal side of the bottom end cap a thermoelectric cooler (MELCOR

  3. VT Built Up Lands in Grand Isle County - 1986

    Vermont Center for Geographic Information — (Link to Metadata) NRCS mapped historical and current-day built-up lands for Grand Isle County, VT using several vintages of aerial photography: 1941, 1962, 1974,...

  4. VT Built Up Lands in Grand Isle County - 1941

    Vermont Center for Geographic Information — (Link to Metadata) NRCS mapped historical and current-day built-up lands for Grand Isle County, VT using several vintages of aerial photography: 1941, 1962, 1974,...

  5. Constructing 5d orbifold grand unified theories from heterotic strings

    Kobayashi, Tatsuo; Raby, Stuart; Zhang Renjie

    2004-01-01

    A three-generation Pati-Salam model is constructed by compactifying the heterotic string on a particular T 6 /Z 6 Abelian symmetric orbifold with two discrete Wilson lines. The compactified space is taken to be the Lie algebra lattice G 2 -bar SU(3)-bar SO(4). When one dimension of the SO(4) lattice is large compared to the string scale, this model reproduces many features of a 5d SO(10) grand unified theory compactified on an S 1 /Z 2 orbifold. (Of course, with two large extra dimensions we can obtain a 6d SO(10) grand unified theory.) We identify the orbifold parities and other ingredients of the orbifold grand unified theories in the string model. Our construction provides a UV completion of orbifold grand unified theories, and gives new insights into both field theoretical and string theoretical constructions

  6. 27 CFR 9.119 - Middle Rio Grande Valley.

    2010-04-01

    ... Middle Rio Grande Valley. (a) Name. The name of the viticultural area described in this section is... 1979. (24) Veguita, N. Mex. (1952), revised 1979. (25) Wind Mesa, N. Mex. (1952), revised 1967. (c...

  7. A GRAND PLAN FOR EARTH LOVE EDUCATION IN SOUTHERN ...

    cognition. From this doubtful synthesis, the researcher appears to have constructed a grand theory of how the world without ... problem here is that all of the students (English. Xhosa and ..... accompanying 'earthy music' will contrihute to.

  8. Casa Grande Ruins National Monument acoustical monitoring 2010

    2014-11-01

    During September 2010, The Volpe Center collected baseline acoustical data at Casa Grande National Monument (CAGR), at one site for 28 days. The baseline data collected during this period will help park managers and planners estimate the effects of f...

  9. Flocculent and grand design spiral arm structure in cluster galaxies

    Elmegreen, D.M.

    1982-01-01

    A total of 829 spiral galaxies in 22 clusters having redshifts between z = 0.02 and 0.06 were classified according to the appearance of their spiral arm structures. The fraction of galaxies that have a grand design spiral structure was found to be higher among barred galaxies than among non-barred galaxies (at z = 0.02, 95 per cent of strongly barred galaxies have a grand design, compared with 67 per cent of non-barred or weakly barred galaxies). Cluster galaxies and distant non-cluster galaxies have the same fraction of grand design galaxies when resolution effects are considered. The grand design fraction among cluster galaxies is also similar to the fraction observed among nearby galaxies in binary systems and in groups. (author)

  10. Albuquerque/Middle Rio Grande Urban Waters Viewer

    U.S. Environmental Protection Agency — These data have been compiled in support of the Middle Rio Grande/Albuquerque Urban Waters Partnership for the region including Albuquerque, New Mexico.The Middle...

  11. Evaluation unit of X-ray spectrometer

    Polivka, V.

    1986-01-01

    The evaluation unit is designed as a CAMAC modular system. It processes analog signals from the detector, amplifies them, digitizes them, stores them, and displays them. The analog data collection system consists of a high voltage supply, a linear amplifier, and an analog-to-digital convertor. The digital part of the data collection system consists of a data memory and a mapping unit. The control and calculation system consisting of a controller, a memory, an expandable working memory, a floppy disk controller, a parallel input and output for the terminal, and a controller for block transfer, provides the control of the entire spectrometer and the calculations for qualitative and quantitative analyses. It also provides connection to the peripherals: the disk operating system, the graphics terminal with keyboard, and the mosaic printer. (M.D.)

  12. A summation free β+-endpoint spectrometer

    Keller, H.; Kirchner, R.; Klepper, O.; Roeckl, E.; Schardt, D.; Simon, R.S.; Kleinheinz, P.; Liang, C.F.; Paris, P.

    1990-08-01

    A β + -endpoint spectrometer is described, where positrons are observed in an 11-mm thick silicon detector in coincidence with subsequent γ-rays meausred in a germanium detector, and where the summing of the positron energy with the annihilation radiation is prevented by detecting both 511-keV quanta in opposite segments of a BGO ring surrounding the silicon detector. The procedure of measuring and analyzing the data is outlined for the decay of the 11/2 - -isomer of 149 Tb; its endpoint energy is determined to be 1853(10) keV, in agreement with the literature. The accuracy and reliability of β + -endpoint measurements is discussed in comparison to the EC/β + -ratio method. (orig.)

  13. The Alpha Magnetic Spectrometer Silicon Tracker

    Burger, W J

    1999-01-01

    The Alpha Magnetic Spectrometer (AMS) is designed as a independent module for installation on the International Space Station Alpha (ISSA) in the year 2002 for an operational period of three years. The principal scientific objectives are the searches for antimatter and dark matter in cosmic rays. The AMS uses 5.5 m sup 2 of silicon microstrip sensors to reconstruct charged particle trajectories in the field of a permanent magnet. The detector design and construction covered a 3 yr period which terminated with a test flight on the NASA space shuttle Discovery during June 2-12, 1988. In this contribution, we describe the shuttle version of the AMS silicon tracker, including preliminary results of the tracker performance during the flight. (author)

  14. Background characterization in a liquid scintillation spectrometer

    Rodriguez Barquero, L.; Los Arcos, J.M.; Jimenez de Mingo, A.

    1995-01-01

    An alternate procedure for background count rate estimation in a liquid scintillation spectrometer is presented, which does not require to measure a blank with similar composition, volume and quench, to the problem sample. The procedure is based on a double linear parameterization which was obtained from a systematic study of the background observed with glass vials, in three different windows, 0 - 20 KeV, 0 - 800 KeV and 0 - 2 MeV, for volume between 2 and 20 mi of three commercial scintillators, Hisafe II, Ultima-Gold and Instagel, and quenching degree in the interval equivalent to 50% - 3% tritium efficiency. This procedure was tested with standard samples of 3H, and led to average discrepancies less than 10% for activity ≥0,6 Bq, against conventional methods for which the discrepancies are twice on average. (Author) 10 refs

  15. Background characterization in a liquid scintillation spectrometer

    Rodriguez Barquero, L.; Los arcos, J.M.; Jimenez de Mingo, A.

    1995-01-01

    An alternate procedure for background count rate estimation in a liquid scintillation spectrometer is presented, which does not require to measure a blank with similar composition, volume and quench, to the problem sample. The procedure is based on a double linear parameterization which was obtained from a systematic study of the background observed with glass vials, in three different windows, 0-20 KeV, 0-800 KeV and 0-2 MeV, for volume between 2 and 20 ml of three commercial scintillators, Hisafe II, Ultima-gold and Instagel, and quenching degree in the interval equivalent to 50%-3% tritium efficiency. This procedure was tested with standard samples of ''3 H, and led to average discrepancies less than 10% for activity => 0,6 Bq, against conventional methods for which the discrepancies are twice on average

  16. Spectrometer system for diffuse extreme ultraviolet radiation

    Labov, Simon E.

    1989-01-01

    A unique grazing incidence spectrometer system has been designed to study diffuse line emission between 80 and 650 A with 10-30 A resolution. The minimum detectable emission line strength during a 5-min observation ranges from 100-2000 ph/sq cm sec str. The instrument uses mechanically ruled reflection gratings placed in front of a linear array of mirrors. These mirrors focus the spectral image on microchannel plate detectors located behind thin filters. The field of view is 40 min of arc by 15 deg, and there is no spatial imaging. This instrument has been fabricated, calibrated, and successfully flown on a sounding rocket to observe the astronomical background radiation.

  17. Design of a large superconducting spectrometer magnet

    Shintomi, T.; Makida, Y.; Mito, T.; Yamanoi, Y.; Hashimito, O.; Nagae, T.

    1989-04-01

    The superconducting spectrometer magnet for nuclear physics experiments has been under construction by Institute for Nuclear Study, University of Tokyo with collaboration from KEK. The magnet has a sector type coil. The magnetic field is 3 T with the magnet gap of 50 cm and the stored energy is 11.8 MJ. The easy operation and maintenance are taken into consideration in addition to usual design concept. Three dimensional magnetic field calculation and the stress analysis have been performed. The code 'QUENCH' was applied to decide the operation current and to check the safety of the coil. As a result, the current of 500 A was selected. The heat leaks were checked and estimated less than 2 W at 4 K. A small refrigerator is to be used for thermal insulations at 80 and 20 K. (author)

  18. Borehole instrument for scintillation gamma spectrometer

    Sinitsyn, A.Ya.; Gabitov, R.M.

    1979-01-01

    Described are a schematic diagram and main specifications of a borehole instrument with autostabilization of energy scale measure by gamma bench-mark of 137 Cs, intended for the application in a logging gamma spectrometer to determine separately the concentrations of nature radioactive elements. The instrument may be connected to the KOBDFM-2 cable of 600 m length. It contains a scintillation counter for gamma quanta consisting of 30x70 mm NaI(Tl) crystal and a FEU-85 photoamplifier, an input conforming stage, a diagram of threshold pulse formation and regulating high-voltage generator. The borehole instrument has been proved under laboratory and field conditions at 10-40 deg C

  19. The gamma ray spectrometer GA.SP

    Bazzacco, D [Instituto Nazionale di Fisica Nucleare, Sezione di Padova, Padova (Italy)

    1992-08-01

    GA.SP is a general purpose 4{pi} detector array for advanced {gamma}-spectroscopy and, in the same time, a suitable system for reaction mechanism studies. The detector is sited at the LNL Tandem+Linac accelerator and has been built as a joint project of INFN Padova, LNL, Milano and Firenze. The array consists of 40 Compton suppressed HPGe detectors and of a 4{pi} calorimeter composed of 80 BGO crystals. The detector houses a reaction chamber of 34 cm diameter where a charged particles multiplicity filter composed of 40 Si detectors is going to be installed. Evaporation residues produced in the centre of GA.SP can be injected into the recoil mass spectrometer (RMS, named CAMEL) in use at LNL, without the need to remove any of the gamma detectors. The coupled operation of GA.SP, RMS and Si ball will give a unique instrument for identification and study of weak reaction channels. (author). 6 figs.

  20. The gamma ray spectrometer GA.SP

    Bazzacco, D.

    1992-01-01

    GA.SP is a general purpose 4π detector array for advanced γ-spectroscopy and, in the same time, a suitable system for reaction mechanism studies. The detector is sited at the LNL Tandem+Linac accelerator and has been built as a joint project of INFN Padova, LNL, Milano and Firenze. The array consists of 40 Compton suppressed HPGe detectors and of a 4π calorimeter composed of 80 BGO crystals. The detector houses a reaction chamber of 34 cm diameter where a charged particles multiplicity filter composed of 40 Si detectors is going to be installed. Evaporation residues produced in the centre of GA.SP can be injected into the recoil mass spectrometer (RMS, named CAMEL) in use at LNL, without the need to remove any of the gamma detectors. The coupled operation of GA.SP, RMS and Si ball will give a unique instrument for identification and study of weak reaction channels. (author). 6 figs

  1. Commissioning of a proton-recoil spectrometer

    Nunes, J.C.; Faught, R.T.

    2000-01-01

    Measurements of neutron fluence spectra in fields from bare and heavy-water-moderated 252 Cf were made with a commercially available proton-recoil spectrometer (PRS) that covers 50 keV to 4.5 MeV. Data obtained from these measurements were compared with data from Bonner sphere spectrometry, Monte Carlo simulation and the open literature. Alterations to the input data file used in unfolding recoil-proton pulse-height distributions were made. Understanding the reasons for these changes and considering the effects of some of the results in an appreciation of the significance of parameters used in the unfolding. An uncertainty of 10% is estimated for values of fluence and ambient dose equivalent for the energy region covered by this PRS. (author)

  2. Polarized triple-axis spectrometer TASP

    Boeni, P; Keller, P [Lab. for Neutron Scattering ETH Zurich, Zurich (Switzerland) and Paul Scherrer Institute, Villigen (Switzerland)

    1996-11-01

    The polarized triple-axis spectrometer TASP at SINQ has been optimized for measuring magnetic cross sections in condensed matter. The neutrons are polarized or analyzed either by means of benders or Heusler monochromators. The beam divergence, i.e. the intensity, and the spectral range of the neutrons is rather large because of the supermirror coatings of the feeding neutron guide. The intensity can be further increased at the sample position by means of a focussing monochromator and a focussing anti-trumpet. The end position of TASP allows the tailoring of the neutron beam already before the monochromator and to scatter neutrons over very wide ranges of angles. (author) 6 figs., 1 tab., 8 refs.

  3. Alpha particles spectrometer with photodiode PIN

    Chacon R, A.; Hernandez V, R.; Hernandez D, V. M.; Vega C, H. R.; Ramirez G, J.

    2009-10-01

    The radiation propagates in form of electromagnetic waves or corpuscular radiation; if the radiation energy causes ionization in environment that crosses it is considered ionizing radiation. To detect radiation several detectors types are used, if the radiation are alpha particles are used detectors proportional type or trace elements. In this work the design results, construction and tests of an alpha particles spectrometer are presented, which was designed starting from a photodiode PIN type. The system design was simulated with a code for electronic circuits. With results of simulation phase was constructed the electronic phase that is coupled to a multichannel analyzer. The resulting electronic is evaluated analyzing the electronic circuit performance before an alphas triple source and alpha radiation that produce two smoke detectors of domestic use. On the tests phase we find that the system allows obtain, in a multichannel, the pulses height spectrum, with which we calibrate the system. (Author)

  4. Geometrically weighted semiconductor Frisch grid radiation spectrometers

    McGregor, D.S. [Dept. of Nuclear Engineering and Radiological Sciences, University of Michigan, Ann Arbor, MI 48109-2104 (United States); Rojeski, R.A. [Etec Systems, Inc., 26460 Corporate Ave., Hayward, CA 94545 (United States); He, Z. [Dept. of Nuclear Engineering and Radiological Sciences, University of Michigan, Ann Arbor, MI 48109-2104 (United States); Wehe, D.K. [Dept. of Nuclear Engineering and Radiological Sciences, University of Michigan, Ann Arbor, MI 48109-2104 (United States); Driver, M. [eV Products, 375 Saxonburg Blvd., Saxonburg, PA 16056 (United States); Blakely, M. [eV Products, 375 Saxonburg Blvd., Saxonburg, PA 16056 (United States)

    1999-02-11

    A new detector geometry is described with relatively high gamma ray energy resolution at room temperature. The device uses the geometric weighting effect, the small pixel effect and the Frisch grid effect to produce high gamma ray energy resolution. The design is simple and easy to construct. The device performs as a gamma ray spectrometer without the need for pulse shape rejection or correction, and it requires only one signal output to any commercially available charge sensitive preamplifier. The device operates very well with conventional NIM electronic systems. Presently, room temperature (23 deg. C) energy resolutions of 2.68% FWHM at 662 keV and 2.45% FWHM at 1.332 MeV have been measured with a 1 cm{sup 3} prism shaped CdZnTe device.

  5. Miniaturisation of imaging spectrometer for planetary exploration

    Drossart, Pierre; Sémery, Alain; Réess, Jean-Michel; Combes, Michel

    2017-11-01

    Future planetary exploration on telluric or giant planets will need a new kind of instrumentation combining imaging and spectroscopy at high spectral resolution to achieve new scientific measurements, in particular for atmospheric studies in nadir configuration. We present here a study of a Fourier Transform heterodyne spectrometer, which can achieve these objectives, in the visible or infrared. The system is composed of a Michelson interferometer, whose mirrors have been replaced by gratings, a configuration studied in the early days of Fourier Transform spectroscopy, but only recently reused for space instrumentation, with the availability of large infrared mosaics. A complete study of an instrument is underway, with optical and electronic tests, as well as data processing analysis. This instrument will be proposed for future planetary missions, including ESA/Bepi Colombo Mercury Planetary Orbiter or Earth orbiting platforms.

  6. J-NSE: Neutron spin echo spectrometer

    Olaf Holderer

    2015-08-01

    Full Text Available Neutron Spin-Echo (NSE spectroscopy is well known as the only neutron scattering technique that achieves energy resolution of several neV. By using the spin precession of polarized neutrons in magnetic field one can measure tiny velocity changes of the individual neutron during the scattering process. Contrary to other inelastic neutron scattering techniques, NSE measures the intermediate scattering function S(Q,t in reciprocal space and time directly. The Neutron Spin-Echo spectrometer J-NSE, operated by JCNS, Forschungszentrum Jülich at the Heinz Maier-Leibnitz Zentrum (MLZ in Garching, covers a time range (2 ps to 200 ns on length scales accessible by small angle scattering technique. Along with conventional NSE spectroscopy that allows bulk measurements in transmission mode, J-NSE offers a new possibility - gracing incidence spin echo spectroscopy (GINSENS, developed to be used as "push-button" option in order to resolve the depth dependent near surface dynamics.

  7. Nalisis Kinerja Keuangan pada PT. Grand Victoria Hotel di Samarinda

    -, Atmajaya -

    2013-01-01

    Based on the results of analysis show that the performance of PT. Hotel Grand Victorian is measured using liquidity ratios and profitability ratios decreased from 2010-2012. Performance PT. Grand Victorian is measured using the liquidity ratio has decreased from year 2010-2012 consists of current ratio has decreased, and this is because the total current assets has increased and decreased. Meanwhile, the cash ratio from year 2010-2012 has increased, this is because the total cash and cash equ...

  8. Simulations of Precipitation Variability over the Upper Rio Grande Basin

    Costigan, Keeley R.; Bossert, James E.; Langley, David L.

    1997-10-01

    In this research, we study Albuquerque's water and how it may be affected by changes in the regional climate, as manifested by variations in Rio Grande water levels. To do this, we rely on the use of coupled atmospheric, runoff, and ground water models. Preliminary work on the project has focused on uncoupled simulations of the aquifer beneath Albuquerque and winter precipitation simulations of the upper Rio Grande Basin. The latter is discussed in this paper

  9. Restrictions on SU(5) as a grand unified theory

    Shellard, R.C.

    1984-01-01

    Some restrictions imposed upon Grand Unified Theories by dynamical symetry breakdown are examined. They are shown that, in particular, theories SU(5) as symmetry group, with 3 or more fermion families undergo dynamical symmetry breakdown, and some of the fermions will acquire mass at the Grand Unified scale. On the other hand, the SO(10) group, with 3 families is free from this problem. (Author) [pt

  10. LANL/Green Star spectrometer tests

    Sampson, T.E.; Cremers, T.L.; Vo, D.T.; Seldiakov, Y.P.; Dorin, A.B.; Kondrashov, M.V.; Timoshin, V.I.

    1997-12-01

    The US and Russia have agreed to the joint development of a nondestructive assay system for use to support the dismantlement of nuclear weapons in Russia. This nondestructive assay system will be used to measure plutonium produced by the conversion of Russian nuclear weapons. The NDA system for Russia will be patterned after the ARIES NDA system being constructed at Los Alamos. One goal of the program is to produce an NDA system for use in Russia that maximizes the use of Russian resources to facilitate maintenance and future upgrades. The Green Star SBS50 Single Board Spectrometer system (Green Star Ltd., Moscow, Russia) has been suggested for use as the data acquisition component for gamma ray instruments in the system. Possible uses are for plutonium isotopic analysis and also segmented gamma scanning. Green Star has also developed analysis software for the SBS50. This software, both plutonium isotopic analysis and uranium enrichment analysis, was developed specifically for customs/border inspection applications (low counting rate applications and identification as opposed to quantification) and was not intended for MC and A applications. Because of the relative immaturity of the Green Star plutonium isotopic analysis software (it has been under development for only one year and is patterned after US development circa 1980), it was tentatively agreed, before the tests, that the Russian NDA system would use the Los Alamos PC/FRAM software for plutonium isotopic analysis. However, it was also decided to include the Green Star plutonium isotopic software in the testing, both to quantify its performance for MC and A applications and also to provide additional data to Green Star for further development of their software. The main purpose of the testing was to evaluate the SBS-50 spectrometer as a data acquisition device for use with LANL software

  11. Compact imaging Bragg spectrometer for fusion devices

    Bertschinger, G.; Biel, W.; Jaegers, H.; Marchuk, O.

    2004-01-01

    A compact imaging x-ray spectrometer has been designed for tokamaks and stellarators to measure the plasma parameters at different spatial chords. It has been optimized for high spectral resolution and high sensitivity. High spectral resolution is obtained by using solid state detectors and minimizing the imaging errors of the spherical crystals. It is shown, that using spherical crystals the solid angle and hence the throughput can be increased significantly, without compromising the spectral resolution. The design is useful for the measurement of the spectra of He- and H-like ions from Si to Kr. The spectral resolution is sufficient for the measurement of plasma parameters. The temporal resolution is high enough for transport studies by gas puff and laser ablation experiments. The design is based on a modified Johann spectrometer mount, utilizing a spherically bent crystal instead of the cylindrically bent crystal in the traditional Johann mount. The astigmatism of the wavelength selective reflection on the spherical crystal is applied to obtain imaging of an extended plasma source on a two-dimensional detector. For each element, a separate crystal is required, only in few cases, a crystal can be used for the spectra of two elements. For the spectra of most of the He-like ions from Si up to Kr, suitable crystal cuts have been found on quartz, silicon and germanium crystals with Bragg angles in a small interval around the design value of 53.5 deg. All of the crystals have the same radius. They are fixed on a rotational table. The distance to the detector is adjusted by an x-y table to fit to the Rowland circle

  12. Tres grandes plataformas marinas Mar del Norte

    Soulas, R.

    1978-03-01

    Full Text Available This article analyzes the different building stages of three large sea platforms. After studying the structure's main characteristics, preparing scale models and calculating ail the elements, platform construction was carried out in three stages: — Dry-dock construction of the hull base. — Installation in the water and finishing the structure. — Immersion and bridge installation. Finally, the necessary operations to move the platform to its definite location were carried out. The structures are formed by a parallelepiped hull of reinforced concrete, divided into compartments by means of vertical orthogonals panels on top of which 2 or 4 piles are placed to support the bridge.

    En este artículo se analizan las diversas etapas en la realización de tres grandes plataformas marinas. Después de un estudio de las características principales de la estructura, ensayos en modelo reducido y cálculo de todos los elementos, se procede a la construcción de las plataformas en tres fases: — Construcción en seco de la base del casco. — Colocación en el agua y acabado de la estructura. — Inmersión y colocación del puente. Por último, se realizan las operaciones necesarias para llevar la plataforma a su ubicación definitiva. Las estructuras están formadas por un casco paralelepipédico de hormigón armado, dividido en compartimientos mediante tabiques verticales ortogonales y sobre el que se han colocado 2 ó 4 pilas que soportan el puente.

  13. Combined Raman/LIBS spectrometer elegant breadboard: built and tested - and flight model spectrometer unit

    Ahlers, B.; Hutchinson, I.; Ingley, R.

    2017-11-01

    A spectrometer for combined Raman and Laser Induced Breakdown Spectroscopy (LIBS) is amongst the different instruments that have been pre-selected for the Pasteur payload of the ExoMars rover. It is regarded as a fundamental, next-generation instrument for organic, mineralogical and elemental characterisation of Martian soil, rock samples and organic molecules. Raman spectroscopy and LIBS will be integrated into a single instrument sharing many hardware commonalities [1]. The combined Raman / LIBS instrument has been recommended as the highest priority mineralogy instrument to be included in the rover's analytical laboratory for the following tasks: Analyse surface and sub-surface soil and rocks on Mars, identify organics in the search for life and determine soil origin & toxicity. The synergy of the system is evident: the Raman spectrometer is dedicated to molecular analysis of organics and minerals; the LIBS provides information on the sample's elemental composition. An international team, under ESA contract and with the leadership of TNO Science and Industry, has built and tested an Elegant Bread Board (EBB) of the combined Raman / LIBS instrument. The EBB comprises a specifically designed, extremely compact, spectrometer with high resolution over a large wavelength range, suitable for both Raman spectroscopy and LIBS measurements. The EBB also includes lasers, illumination and imaging optics as well as fibre optics for light transfer. A summary of the functional and environmental requirements together with a description of the optical design and its expected performance are described in [2]. The EBB was developed and constructed to verify the instruments' end-to-end functional performance with natural samples. The combined Raman / LIBS EBB realisation and test results of natural samples will be presented. For the Flight Model (FM) instrument, currently in the design phase, the Netherlands will be responsible for the design, development and verification of the

  14. Evaluation of HOPG mounting possibilities for multiplexing spectrometers

    Groitl, Felix; Bartkowiak, Marek; Bergmann, Ryan M.

    2017-01-01

    Four different methods for mounting HOPG analyzer crystals on Si holders have been evaluated in the design process of the new multiplexing spectrometer CAMEA. Contrary to neutron optics used in standard spectrometers, the new instrument concept employs a series of analyzer segments behind each...

  15. Linear Fresnel Spectrometer Chip with Gradient Line Grating

    Choi, Sang Hyouk (Inventor); Park, Yeonjoon (Inventor)

    2015-01-01

    A spectrometer that includes a grating that disperses light via Fresnel diffraction according to wavelength onto a sensing area that coincides with an optical axis plane of the grating. The sensing area detects the dispersed light and measures the light intensity associated with each wavelength of the light. Because the spectrometer utilizes Fresnel diffraction, it can be miniaturized and packaged as an integrated circuit.

  16. Dye laser spectrometer for the analysis of pulsed vacuum arcs

    Hargis, P.J. Jr.; Robertson, M.M.

    1975-01-01

    A pulsed dye laser spectrometer which is used to obtain detailed single shot spectroscopic measurements of the plasma in a pulsed vacuum arc was developed. The capabilities of this spectrometer are indicated by the detection of laser induced fluorescence signals from 10 6 neutral Ti atoms in the plasma of a pulsed vacuum arc with a Ti anode. (U.S.)

  17. Inexpensive Raman Spectrometer for Undergraduate and Graduate Experiments and Research

    Mohr, Christian; Spencer, Claire L.; Hippler, Michael

    2010-01-01

    We describe the construction and performance of an inexpensive modular Raman spectrometer that has been assembled in the framework of a fourth-year undergraduate project (costs below $5000). The spectrometer is based on a 4 mW 532 nm green laser pointer and a compact monochromator equipped with glass fiber optical connections, linear detector…

  18. Multi-spectrometer calibration transfer based on independent component analysis.

    Liu, Yan; Xu, Hao; Xia, Zhenzhen; Gong, Zhiyong

    2018-02-26

    Calibration transfer is indispensable for practical applications of near infrared (NIR) spectroscopy due to the need for precise and consistent measurements across different spectrometers. In this work, a method for multi-spectrometer calibration transfer is described based on independent component analysis (ICA). A spectral matrix is first obtained by aligning the spectra measured on different spectrometers. Then, by using independent component analysis, the aligned spectral matrix is decomposed into the mixing matrix and the independent components of different spectrometers. These differing measurements between spectrometers can then be standardized by correcting the coefficients within the independent components. Two NIR datasets of corn and edible oil samples measured with three and four spectrometers, respectively, were used to test the reliability of this method. The results of both datasets reveal that spectra measurements across different spectrometers can be transferred simultaneously and that the partial least squares (PLS) models built with the measurements on one spectrometer can predict that the spectra can be transferred correctly on another.

  19. A perturbed angular correlation spectrometer for material science ...

    A four-detector perturbed angular correlation (PAC) spectrometer has been developed with ultra-fast BaF2 detectors to acquire four coincidence spectra simultaneously, two at 180° and two at 90°. This spectrometer has double efficiency compared to that of a three-detector set-up. Higher efficiency is desirable for PAC ...

  20. On a low intensity 241 Am Compton spectrometer for measurement ...

    In this paper, a new design and construction of a low intensity (100 mCi) 241Am -ray Compton spectrometer is presented. The planar spectrometer is based on a small disc source with the shortest geometry. Measurement of the momentum density of polycrystalline Al is used to evaluate the performance of the new design.

  1. Spectrometer for external detection of magnetic and related double resonance

    Sagalyn, P.L.; Alexander, M.N.

    1977-01-01

    The patent relates to an improvement in nuclear magnetic resonance spectrometer apparatus. It consists of a spectrometer which utilizes separate materials containing, respectively, sample and detector spin systems as opposed to one in which the sample and detector spins are contained in the same single material

  2. Workshop on high-resolution, large-acceptance spectrometers

    Zeidman, B. (ed.)

    1981-01-01

    The purpose of the Workshop on High-Resolution, Large-Acceptance Spectrometers was to provide a means for exchange of information among those actively engaged in the design and construction of these new spectrometers. Thirty-seven papers were prepared for the data base.

  3. An improved computer controlled triple-axis neutron spectrometer

    Cooper, M.J.; Hall, J.W.; Hutchings, M.T.

    1975-07-01

    A description is given of the computer-controlled triple-axis neutron spectrometer installed at the PLUTO reactor at Harwell. The reasons for an nature of recent major improvements are discussed. Following a general description of the spectrometer, details are then given of the new computerised control system, including the functions of the various programs which are now available to the user. (author)

  4. Wide-aperture magnetic spectrometer with face position of MWPC

    Avakyan, R.O.; Avetisyan, A.Eh.; Ajvazyan, R.B.; Asaturyan, R.A.; Dallakyan, K.R.; Kizogyan, O.S.; Matevosyan, Eh.M.; Sukiasyan, Yu.Z.; Taroyan, S.P.

    1988-01-01

    A pair magnetic spectrometer with automated wire chambers for studying electron and positron interactions with monocrystals at the Erevan synchrotron is described. As a working gas the argon-methane mixture with methylal vapor addition is used. Results of modelling and experiments with spectrometer are presented. 2 refs.; 6 figs

  5. GEANT Monte Carlo simulations for the GREAT spectrometer

    Andreyev, A.N.; Butler, P.A.; Page, R.D.; Appelbe, D.E.; Jones, G.D.; Joss, D.T.; Herzberg, R.-D.; Regan, P.H.; Simpson, J.; Wadsworth, R.

    2004-01-01

    GEANT Monte Carlo simulations for the recently developed GREAT spectrometer are presented. Some novel applications of the spectrometer for γ-ray, conversion-electron and β-decay spectroscopy are discussed. The conversion-electron spectroscopy of heavy nuclei with strongly converted transitions and the extension of the recoil decay tagging method to β-decaying nuclei are considered in detail

  6. Fabrication and testing of the recoil mass spectrometer at Bombay ...

    A recoil mass spectrometer (RMS) has been designed, fabricated and installed ... first order and only mass dispersion is obtained at the focal plane of the ... more details, like, the specifications and a typical beam profile through the ... Further experiments are now in progress to characterize the spectrometer, i.e., to measure.

  7. Tests of a prototype resonance filter spectrometer at WNR

    Newport, R.J.; Seeger, P.A.; Williams, W.G.

    1984-11-01

    Data gained during a series of developmental experiments using the SNS test resonance filter spectrometer at the WNR pulsed neutron facility, Los Alamos, are presented and discussed. The operational experience obtained during the period of these studies has provided some insight into the desirable characteristics and possible limitations of any future spectrometer design and this information is considered in some detail. (author)

  8. Multichannel analyzer for the neutron time-of-flight spectrometer

    Vojter, A.P.; Slyisenko, V.Yi.; Doronyin, M.Yi.; Maznij, Yi.O.; Vasil'kevich, O.A.; Golyik, V.V.; Koval'ov, O.M.; Kopachov, V.Yi.; Savchuk, V.G.

    2010-01-01

    New multichannel time-of-flight spectrometer for the measurement of the energy and angular distributions of neutrons from the WWWR-M reactor is considered. This spectrometer has been developed for the replacement of the previous one to increase the number of channels and measurement precision, reduce the time of channel tuning and provide the automatic monitoring during the experiment.

  9. High Resolution Stellar Spectroscopy with VBT Echelle Spectrometer

    Easy operations. We finally preferred the all transmitting system for the spectrometer with the optical surfaces anti-reflection coated to optimize the throughput rather than reflecting cameras with central obscurations. Following other optimized throughput spectrometers like. Sandiford at McDonald Observatory (McCarthy et al ...

  10. Theoretical resolving power of a radiofrequency mass spectrometer

    Coc, A.; Le Gac, R.; Saint Simon, M. de; Thibault, C.; Touchard, F.

    1988-01-01

    Radiofrequency mass spectrometers of L.G. Smith's type can reach a resolving power of 10 6 -10 7 and a precision of 10 -9 -10 -10 . The resolving power, shape of peaks and limitations are described. As an example, the spectrometer to be used in an experiment aimed at measuring the anti p/p mass ratio is considered. (orig.)

  11. Automation, development and performance of a photoacoustic spectrometer

    Cavalheiro, F.R.F.

    1985-01-01

    This work consists in the development of a circuit to interface a photoacoustic spectrometer with a microcomputer. The obtained spectra are identical to those obtained in commercial photoacoustic spectrometers. The system permits a great versatility and it has possibilities to automatize other types of experiments. The system can be duplicated from national components and at a relatively low coast. (author)

  12. Use of UAV-Borne Spectrometer for Land Cover Classification

    Sowmya Natesan

    2018-04-01

    Full Text Available Unmanned aerial vehicles (UAV are being used for low altitude remote sensing for thematic land classification using visible light and multi-spectral sensors. The objective of this work was to investigate the use of UAV equipped with a compact spectrometer for land cover classification. The UAV platform used was a DJI Flamewheel F550 hexacopter equipped with GPS and Inertial Measurement Unit (IMU navigation sensors, and a Raspberry Pi processor and camera module. The spectrometer used was the FLAME-NIR, a near-infrared spectrometer for hyperspectral measurements. RGB images and spectrometer data were captured simultaneously. As spectrometer data do not provide continuous terrain coverage, the locations of their ground elliptical footprints were determined from the bundle adjustment solution of the captured images. For each of the spectrometer ground ellipses, the land cover signature at the footprint location was determined to enable the characterization, identification, and classification of land cover elements. To attain a continuous land cover classification map, spatial interpolation was carried out from the irregularly distributed labeled spectrometer points. The accuracy of the classification was assessed using spatial intersection with the object-based image classification performed using the RGB images. Results show that in homogeneous land cover, like water, the accuracy of classification is 78% and in mixed classes, like grass, trees and manmade features, the average accuracy is 50%, thus, indicating the contribution of hyperspectral measurements of low altitude UAV-borne spectrometers to improve land cover classification.

  13. SMARTS - a spectrometer for strain measurement in engineering materials

    Bourke, M.A.M. [MS H805, Los Alamos National Laboratory, Los Alamos, NM, 87545 (United States); Dunand, D.C. [Department of Materials Science and Engineering, Northwestern University, Cook Hall, Evanston, IL, 60208 (United States); Ustundag, E. [Department of Materials Science, California Institute of Technology, Pasadena, CA 91125 (United States)

    2002-07-01

    A new spectrometer called SMARTS (Spectrometer for Materials Research at Temperature and Stress) has been commissioned at the Los Alamos neutron science center and entered the user program in August of 2002. Its design maximizes capability and throughput for measurements of (a) residual macrostrain in engineering components and (b) in situ loading. This paper describes some aspects of the instrument. (orig.)

  14. SMARTS - a spectrometer for strain measurement in engineering materials

    Bourke, M A M; Ustundag, E

    2002-01-01

    A new spectrometer called SMARTS (Spectrometer for Materials Research at Temperature and Stress) has been commissioned at the Los Alamos neutron science center and entered the user program in August of 2002. Its design maximizes capability and throughput for measurements of (a) residual macrostrain in engineering components and (b) in situ loading. This paper describes some aspects of the instrument. (orig.)

  15. Scanning electron microscopy-energy dispersive X-ray spectrometer ...

    The distribution of arsenic (As) and cadmium (Cd) in himematsutake was analyzed using scanning electron microscopy-energy dispersive X-ray spectrometer (SEM-EDX). The atomic percentage of the metals was confirmed by inductively coupled plasma-mass spectrometer (ICP-MS). Results show that the accumulation of ...

  16. Gamma-ray spectrometer utilizing xenon at high pressure

    Smith, G.C.; Mahler, G.J.; Yu, B.; Kane, W.R.; Markey, J.K.

    1994-01-01

    A prototype gamma-ray spectrometer utilizing xenon gas near the critical point (166 degrees C, 58 atm) is under development. The spectrometer will function as a room-temperature ionization chamber detecting gamma rays in the energy range 100 keV2 MeV, with an energy resolution intermediate between semiconductor (Ge) and scintillation (NaI) spectrometers. The energy resolution is superior to that of a NaI scintillation spectrometer by a substantial margin (approximately a factor 5), and accordingly, much more information can be extracted from a given gamma-ray spectrum. Unlike germanium detectors, the spectrometer possesses the capability for sustained operation under ambient temperature conditions without a requirement for liquid nitrogen

  17. Artificial intelligence for geologic mapping with imaging spectrometers

    Kruse, F. A.

    1993-01-01

    This project was a three year study at the Center for the Study of Earth from Space (CSES) within the Cooperative Institute for Research in Environmental Science (CIRES) at the University of Colorado, Boulder. The goal of this research was to develop an expert system to allow automated identification of geologic materials based on their spectral characteristics in imaging spectrometer data such as the Airborne Visible/Infrared Imaging Spectrometer (AVIRIS). This requirement was dictated by the volume of data produced by imaging spectrometers, which prohibits manual analysis. The research described is based on the development of automated techniques for analysis of imaging spectrometer data that emulate the analytical processes used by a human observer. The research tested the feasibility of such an approach, implemented an operational system, and tested the validity of the results for selected imaging spectrometer data sets.

  18. Enterotoxemia em caprinos no Rio Grande do Sul Caprine enterotoxaemia in Rio Grande do Sul, Brazil

    Edson M. Colodel

    2003-12-01

    Full Text Available São descritos surtos de enterotoxemia em caprinos em cinco propriedades no Estado do Rio Grande do Sul. Os animais afetados eram, normalmente, encontrados mortos ou apresentavam evolução aguda de 2 a 3 horas com acentuada depressão, cólicas abdominais e diarréia profusa com fibrina. Em duas propriedades relataram-se casos com a evolução de até 12 horas. Em treze animais necropsiados observaram-se aumento de líquidos nas cavidades abdominal, torácica e pericárdica, congestão e hiperemia da serosa e mucosa do intestino, conteúdo do cólon líquido com fibrina além de hemorragias de serosa e fibrina. Em um animal constatou-se microangiopatia cerebral caracterizada por acúmulo de material homogêneo e eosinofílico no espaço perivascular. No conteúdo intestinal, colônias com bastonetes morfológica e bioquimicamente sugestivos de Clostridium perfringens foram caracterizadas no estudo bacteriológico. A soroneutralização em camundongos com conteúdo intestinal dos animais afetados, revelou a presença da toxina épsilon. Estes achados evidenciam a enterotoxemia como doença de importância para criação de caprinos no Rio Grande do Sul.Five outbreaks of caprine enterotoxaemia in Rio Grande do Sul, Brazil, were studied. The animals were found dead or had a clinical course that usually lasted 2-3 hours. From two farms a clinical manifestation period of 12 hours was reported. Clinical signs were characterized by depression, marked abdominal discomfort, profuse watery diarrhea with fibrin clots, and death. Thirteen necropsies were performed and hydropericardium, hydrothorax and hydroperitoneum were commonly found. The mucosa and serosa of the colon were congested, and its contents was watery with multiple fibrin clots. Serosal hemorrhages and fibrin clots in the gallbladder were also seen. Fibrinous colitis and thyphilitis were the most frequent histological changes. Cerebral microangiopathy was observed in one case, which was

  19. 3D View of Grand Canyon, Arizona

    2000-01-01

    The Grand Canyon is one of North America's most spectacular geologic features. Carved primarily by the Colorado River over the past six million years, the canyon sports vertical drops of 5,000 feet and spans a 445-kilometer-long stretch of Arizona desert. The strata along the steep walls of the canyon form a record of geologic time from the Paleozoic Era (250 million years ago) to the Precambrian (1.7 billion years ago).The above view was acquired by the Advanced Spaceborne Thermal Emission and Reflection Radiometer (ASTER) instrument aboard the Terra spacecraft. Visible and near infrared data were combined to form an image that simulates the natural colors of water and vegetation. Rock colors, however, are not accurate. The image data were combined with elevation data to produce this perspective view, with no vertical exaggeration, looking from above the South Rim up Bright Angel Canyon towards the North Rim. The light lines on the plateau at lower right are the roads around the Canyon View Information Plaza. The Bright Angel Trail, which reaches the Colorado in 11.3 kilometers, can be seen dropping into the canyon over Plateau Point at bottom center. The blue and black areas on the North Rim indicate a forest fire that was smoldering as the data were acquired on May 12, 2000.Advanced Spaceborne Thermal Emission and Reflection Radiometer (ASTER) is one of five Earth-observing instruments launched December 18, 1999, on NASA's Terra satellite. The instrument was built by Japan's Ministry of International Trade and Industry. A joint U.S./Japan science team is responsible for validation and calibration of the instrument and the data products. Dr. Anne Kahle at NASA's Jet Propulsion Laboratory, Pasadena, Calif., is the U.S. Science team leader; Moshe Pniel of JPL is the project manager. ASTER is the only high resolution imaging sensor on Terra. The primary goal of the ASTER mission is to obtain high-resolution image data in 14 channels over the entire land surface, as

  20. Performance of the ATLAS muon spectrometer

    Aleksa, M.

    1999-09-01

    ATLAS is a general-purpose experiment for the future large hadron collider (LHC) at CERN. Its Muon Spectrometer will require ∼5500 m 2 of precision tracking chambers to measure the muon tracks along a spectrometer arm of 5 m to 15 m length, embedded in a magnetic field of ∼0.5 T. The precision tracking devices in the Muon System will be high pressure drift tubes (MDTs). Approximately 370,000 MDTs will be assembled into ∼1200 drift chambers. The LHC physics discovery range indicates the need for a momentum resolution of ∼10 % for muons with a transverse momentum of p T =1 TeV/c. Following a detailed engineering optimisation of the magnetic-field strength versus the chamber resolution, the ATLAS collaboration opted for a drift-chamber system with very high spatial resolution, σ 2 93/7). Measurements performed in a high-background environment - similar to the ATLAS operational environment - gave us a complete understanding of the individual effects which deteriorate the spatial resolution at high rates. Four effects responsible for a resolution deterioration have been identified: two electronics effects which depend on the count rate of a tube (baseline shift and baseline fluctuations), and two space-charge effects that depend on the local count rate (gain drop and field fluctuations). The understanding of these effects had a major impact on the choice of the drift gas and the front-end electronics. The strong dependence of the drift velocity on the drift field is one major disadvantage of the baseline gas. In this work the full set of effects which lead to systematic errors to the track-position measurement in one tube (e.g. variations of the background rate) was investigated and quantified for realistic LHC operating conditions. For the biggest effects analytical corrections are presented. Finally, the muon-system performance was investigated and a calibration method for the absolute mass scale developed. By means of simulation it was shown that the energy

  1. The Polaris-H imaging spectrometer

    Wahl, Christopher G., E-mail: chris@h3dgamma.com; Kaye, Willy R.; Wang, Weiyi; Zhang, Feng; Jaworski, Jason M.; King, Alexis; Boucher, Y. Andy; He, Zhong

    2015-06-01

    Recently, H3D has designed and introduced a gamma-ray imaging spectrometer system named Polaris-H. Polaris-H was designed to perform gamma spectroscopy and imaging throughout nuclear power plants. It integrates a 3D-position-sensitive pixelated CZT detector (20 mm×20 mm×15 mm), associated readout electronics, an embedded computer, a 5-h battery, and an optical camera in a portable water-proof enclosure. The total mass is about 4 kg, and the system startup time is 2 min. Additionally, it has a connection for a tablet, which displays a gamma-ray spectrum and isotope-specific images of the gamma-ray distribution in all directions in real time. List-mode data is saved to an external USB memory stick. Based on pixelated depth-sensing technology, spectroscopy is routinely better than 1.1% FWHM at 662 keV, and imaging efficiency at 662 keV varies less than a factor of two for all directions, except through the battery. Measurements have been performed in contaminated environments, in high radiation fields, and in cramped quarters.

  2. A dual purpose Compton suppression spectrometer

    Parus, J; Raab, W; Donohue, D

    2003-01-01

    A gamma-ray spectrometer with a passive and an active shield is described. It consists of a HPGe coaxial detector of 42% efficiency and 4 NaI(Tl) detectors. The energy output pulses of the Ge detector are delivered into the 3 spectrometry chains giving the normal, anti- and coincidence spectra. From the spectra of a number of sup 1 sup 3 sup 7 Cs and sup 6 sup 0 Co sources a Compton suppression factor, SF and a Compton reduction factor, RF, as the parameters characterizing the system performance, were calculated as a function of energy and source activity and compared with those given in literature. The natural background is reduced about 8 times in the anticoincidence mode of operation, compared to the normal spectrum which results in decreasing the detection limits for non-coincident gamma-rays up to a factor of 3. In the presence of other gamma-ray activities, in the range from 5 to 11 kBq, non- and coincident, the detection limits can be decreased for some nuclides by a factor of 3 to 5.7.

  3. High resolving power spectrometer for beam analysis

    Moshammer, H.W.; Spencer, J.E.

    1992-03-01

    We describe a system designed to analyze the high energy, closely spaced bunches from individual RF pulses. Neither a large solid angle nor momentum range is required so this allows characteristics that appear useful for other applications such as ion beam lithography. The spectrometer is a compact, double-focusing QBQ design whose symmetry allows the Quads to range between F or D with a correspondingly large range of magnifications, dispersion and resolving power. This flexibility insures the possibility of spatially separating all of the bunches along the focal plane with minimal transverse kicks and bending angle for differing input conditions. The symmetry of the system allows a simple geometric interpretationof the resolving power in terms of thin lenses and ray optics. We discuss the optics and the hardware that is proposed to measure emittance, energy, energy spread and bunch length for each bunch in an RF pulse train for small bunch separations. We also discuss how to use such measurements for feedback and feedforward control of these bunch characteristics as well as maintain their stability. 2 refs

  4. Neutron spectra measuring by magnetless hadron spectrometer

    Bayukov, Yu.D.; Buklej, A.E.; Gavrilov, V.B.

    1980-01-01

    The energy resolution, efficiency and background conditions of neutron recording in inclusive nuclear reactions by a magnetless hadron spectrometer (MHS) in the 8-300 MeV energy range. The scheme of apparatus lay-out for measuring neutron recording efficiency is shown. For recording colliding particles with the 3 GeV/c momentum four beam scintillation counters, the latter of which of 30x40 mm dimensions and 1 mm thickness defines the working beam range in the target centre, are used. Targets of the 80 mm diameter made of C and Pb (2.08 g/cm 2 and 3.04 g/cm 2 thickness, respectively) are located at the 45 deg angle in respect to the beam direction. Secondary particles escaping at the 90 deg angle are recorded by two telescopes of the scintillation counters. For neutron and γ quanta recording the special scintillation detector of the 20 cm thickness encircled by an anticoincidence counter is used. The neutron recording efficiency is determined on the basis of comparison of the neutron production differential cross sections of the π +- 12 C 6 → nX reactions and of proton production in isotopically symmetric reactions π +- 12 C 6 → pX. The experimental data are in good agreement with the calculation data [ru

  5. The CEBAF large acceptance spectrometer (CLAS)

    Mecking, B.A.; Adams, G.; Ahmad, S.; Anciant, E.; Anghinolfi, M.; Asavapibhop, B.; Asryan, G.; Audit, G.; Auger, T.; Avakian, H.; Ball, J.P.; Barbosa, F.J.; Barrow, S.; Battaglieri, M.; Beard, K.; Berman, B.L.; Bianchi, N.; Boiarinov, S.; Bonneau, P.; Briscoe, W.J.; Brooks, W.K.; Burkert, V.D.; Carman, D.S.; Carstens, T.; Cetina, C.; Christo, S.B.; Cole, P.L.; Coleman, A.; Connelly, J.; Cords, D.; Corvisiero, P.; Crabb, D.; Crannell, H.; Cuevas, R.C.; Degtyarenko, P.V.; Dennis, L.; DeSanctis, E.; DeVita, R.; Distelbrink, J.; Dodge, G.E.; Dodge, W.; Doolittle, G.; Doughty, D.; Dugger, M.; Duncan, W.S.; Dytman, S.; Egiyan, H.; Egiyan, K.S.; Elouadrhiri, L.; Feuerbach, R.J.; Ficenec, J.; Frolov, V.; Funsten, H.; Gilfoyle, G.P.; Giovanetti, K.L.; Golovatch, E.; Gram, J.; Guidal, M.; Gyurjyan, V.; Heddle, D.; Hemler, P.; Hersman, F.W.; Hicks, K.; Hicks, R.S.; Holtrop, M.; Hyde-Wright, C.E.; Insley, D.; Ito, M.M.; Jacobs, G.; Jenkins, D.; Joo, K.; Joyce, D.; Kashy, D.; Khandaker, M.; Kim, W.; Klein, A.; Klein, F.J.; Klusman, M.; Kossov, M.; Kramer, L.; Koubarovski, V.; Kuhn, S.E.; Lake, A.; Lawrence, D.; Longhi, A.; Lukashin, K.; Lachniet, J.; Magahiz, R.A.; Major, W.; Manak, J.J.; Marchand, C.; Martin, C.; Matthews, S.K.; McMullen, M.; McNabb, J.W.C.; Mestayer, M.D.; Minehart, R.; Mirazita, M.; Miskimen, R.; Muccifora, V.; Mueller, J.; Murphy, L.Y.; Mutchler, G.S.; Napolitano, J.; Niculescu, I.; Niczyporuk, B.B.; Nozar, M.; O' Brien, J.T.; Opper, A.K.; O' Meara, J.E.; Pasyuk, E.; Philips, S.A.; Polli, E.; Price, J.W.; Pozdniakov, S.; Qin, L.M.; Raue, B.A.; Riccardi, G.; Ricco, G.; Riggs, C.; Ripani, M.; Ritchie, B.G.; Robb, J.; Ronchetti, F.; Rossi, P.; Roudot, F.; Salgado, C.; Sapunenko, V.; Schumacher, R.A.; Serov, V.S.; Sharabian, Y.G.; Smith, E.E.S. E-mail: elton@jlab.org; Smith, L.C.; Smith, T.; Sober, D.I.; Stavinsky, A.; Stepanyan, S.; Stoler, P.; Taiuti, M.; Taylor, W.M.; Taylor, S.; Tedeschi, D.J.; Thoma, U.; Thompson, R.; Tilles, D.; Todor, L. [and others

    2003-05-11

    The CEBAF large acceptance spectrometer (CLAS) is used to study photo- and electro-induced nuclear and hadronic reactions by providing efficient detection of neutral and charged particles over a good fraction of the full solid angle. A collaboration of about 30 institutions has designed, assembled, and commissioned CLAS in Hall B at the Thomas Jefferson National Accelerator Facility. The CLAS detector is based on a novel six-coil toroidal magnet which provides a largely azimuthal field distribution. Trajectory reconstruction using drift chambers results in a momentum resolution of 0.5% at forward angles. Cherenkov counters, time-of-flight scintillators, and electromagnetic calorimeters provide good particle identification. Fast triggering and high data-acquisition rates allow operation at a luminosity of 10{sup 34} nucleon cm{sup -2} s{sup -1}. These capabilities are being used in a broad experimental program to study the structure and interactions of mesons, nucleons, and nuclei using polarized and unpolarized electron and photon beams and targets. This paper is a comprehensive and general description of the design, construction and performance of CLAS.

  6. Neutrino Spectrometers - A Search for Information

    Gallo, C. F.

    2004-05-01

    Due to their "wave-particle" nature, Neutrinos will undergo Redshifts due to Doppler and/or Space Expansion effects similar to Electromagnetic Radiation (Photons). However, in some situations (ex., Quasars, etc), Photon Redshifts may be due to cumulative energy-loss mechanisms with the intervening medium. In this situation, the corresponding Neutrino Redshifts will be much smaller since the interaction cross-section for neutrino-medium interactions will be much smaller than any photon-medium cross-section. Thus, observation and comparison of photon redshifts vs corresponding neutrinos redshifts will be very informative. If the photon and neutrino redshifts are similar, then a Doppler and/or Space Exapnsion interpretation is justified. It the neutrino redshift is much smaller than any corresponding photon redshift, then an interpretation via a cumulative energy-loss mechanism is justified. This is a very definitive experimental test of redshift interpretations. Since Neutrino Spectrometers are under design and construction, I am most anxious to learn details about their detection capabilities. I am hoping to contact the relevant scientists and explore situations which may yield definitive experimental results in the forseeable future.

  7. Rutherford X-ray spectrometer readout

    Bateman, J.E.

    1978-07-01

    Rutherford electronic X-ray spectrometer readout is based on the combination of two established techniques (a) the detection and location of soft X-rays by means of multichannel electron multiplier arrays (MCP's), and (b) the electronic readout of charge distributions (generally in multi-wire proportional counters) by means of the delay line techniques. In order for the latter device to function well a charge signal of approximately 10 6 electrons must be available to the delay line wand. This is achieved in the present device by means of two cascaded MCP's which can produce electron gains up to approximately 10 8 , and so operate the delay line from the single electron pulses generated at the front face of an MCP by a soft X-ray. The delay line readout technique was chosen because of its simplicity (both in terms of the necessary hardware and the associated electronics), robustness, and ease of implementation. In order to achieve the target spatial resolution of 50 μm (fwhm) or 20 μm (standard deviation) it was necessary to adapt the charge collection system so that the readout takes place from a length of delay line 200 mm long. The general layout of the system and the functions of the electronic circuits are described. Performance testing, setting up procedures and trouble shooting of the system are discussed. (U.K.)

  8. Combined "dual" absorption and fluorescence smartphone spectrometers.

    Arafat Hossain, Md; Canning, John; Ast, Sandra; Cook, Kevin; Rutledge, Peter J; Jamalipour, Abbas

    2015-04-15

    A combined "dual" absorption and fluorescence smartphone spectrometer is demonstrated. The optical sources used in the system are the white flash LED of the smartphone and an orthogonally positioned and interchangeable UV (λex=370  nm) and blue (λex=450  nm) LED. The dispersive element is a low-cost, nano-imprinted diffraction grating coated with Au. Detection over a 300 nm span with 0.42 nm/pixel resolution was carried out with the camera CMOS chip. By integrating the blue and UV excitation sources into the white LED circuitry, the entire system is self-contained within a 3D printed case and powered from the smartphone battery; the design can be scaled to add further excitation sources. Using a customized app, acquisition of absorption and fluorescence spectra are demonstrated using a blue-absorbing and green-emitting pH-sensitive amino-naphthalimide-based fluorescent probe and a UV-absorbing and blue-emitting Zn2+-sensitive fluoro-ionophore.

  9. Toward an Intelligent Ion Mobility Spectrometer (IMS)

    McJunkin, Timothy R.; Scott, Jill R.; Miller, Carla J.

    2003-01-01

    The ultimate goal is to design and build a very smart ion mobility spectrometer (IMS) that can operate autonomously. To accomplish this, software capable of interpreting spectra so that it can be used in control loops for data interpretation as well as adjusting instrument parameters is being developed. Fuzzy logic and fuzzy numbers are used in this IMS spectra classification scheme. Fuzzy logic provides a straight forward method for developing a classification/detection system, whenever rules for classifying the spectra can be described linguistically. Instead of using 'max' and 'min' values, the product of the truth values is used to determine class membership. Using the product allows rule-bases that utilize the AND function to allow each condition to discount truth value in determining membership, while rule-bases with an OR function are allowed to accumulate membership. Fuzzy numbers allow encapsulation of the uncertainties due to ion mobility peak widths as well as measured instrumental parameters, such as pressure and temperature. Associating a peak with a value of uncertainty, in addition to making adjustments to the mobility calculation based on variations in measured parameters, enables unexpected shifts to be more reliably detected and accounted for; thereby, reducing the opportunity for 'false negative' results. The measure of uncertainty is anticipated to serve the additional purpose of diagnosing the operational conditions of the IMS instrument.

  10. The VESUVIO electron volt neutron spectrometer

    Mayers, J.; Reiter, G.

    2012-04-01

    This paper describes the VESUVIO electron volt neutron spectrometer at the ISIS pulsed neutron source and its data analysis routines. VESUVIO is used primarily for the measurement of proton momentum distributions in condensed matter systems, but can also be used to measure the kinetic energies of heavier masses and bulk in-situ sample compositions. A series of VESUVIO runs on the same zirconium hydride sample over the past two years show that (1) kinetic energies of protons can be measured to an absolute accuracy of ˜1%. (2) Measurements of the proton momentum distribution n(p) are highly reproducible from run to run. This shows that small changes in kinetic energy and the detailed shape of n(p) with parameters such as temperature, pressure and sample composition can be reliably extracted from VESUVIO data. (3) The impulse approximation (IA) is well satisfied on VESUVIO. (4) The small deviations from the IA due to the finite momentum transfer of measurement are well understood. (5) There is an anomaly in the magnitude of the inelastic neutron cross-section of the protons in zirconium hydride, with an observed reduction of 10% ± 0.3% from that given in standard tables. This anomaly is independent of energy transfer to within experimental error. Future instrument developments are discussed. These would allow the measurement of n(p) in other light atoms, D, 3He, 4He, Li, C and O and measurement of eV electronic and magnetic excitations.

  11. The VESUVIO electron volt neutron spectrometer

    Mayers, J; Reiter, G

    2012-01-01

    This paper describes the VESUVIO electron volt neutron spectrometer at the ISIS pulsed neutron source and its data analysis routines. VESUVIO is used primarily for the measurement of proton momentum distributions in condensed matter systems, but can also be used to measure the kinetic energies of heavier masses and bulk in-situ sample compositions. A series of VESUVIO runs on the same zirconium hydride sample over the past two years show that (1) kinetic energies of protons can be measured to an absolute accuracy of ∼1%. (2) Measurements of the proton momentum distribution n(p) are highly reproducible from run to run. This shows that small changes in kinetic energy and the detailed shape of n(p) with parameters such as temperature, pressure and sample composition can be reliably extracted from VESUVIO data. (3) The impulse approximation (IA) is well satisfied on VESUVIO. (4) The small deviations from the IA due to the finite momentum transfer of measurement are well understood. (5) There is an anomaly in the magnitude of the inelastic neutron cross-section of the protons in zirconium hydride, with an observed reduction of 10% ± 0.3% from that given in standard tables. This anomaly is independent of energy transfer to within experimental error. Future instrument developments are discussed. These would allow the measurement of n(p) in other light atoms, D, 3 He, 4 He, Li, C and O and measurement of eV electronic and magnetic excitations. (paper)

  12. Towards establishing compact imaging spectrometer standards

    Slonecker, E. Terrence; Allen, David W.; Resmini, Ronald G.

    2016-01-01

    Remote sensing science is currently undergoing a tremendous expansion in the area of hyperspectral imaging (HSI) technology. Spurred largely by the explosive growth of Unmanned Aerial Vehicles (UAV), sometimes called Unmanned Aircraft Systems (UAS), or drones, HSI capabilities that once required access to one of only a handful of very specialized and expensive sensor systems are now miniaturized and widely available commercially. Small compact imaging spectrometers (CIS) now on the market offer a number of hyperspectral imaging capabilities in terms of spectral range and sampling. The potential uses of HSI/CIS on UAVs/UASs seem limitless. However, the rapid expansion of unmanned aircraft and small hyperspectral sensor capabilities has created a number of questions related to technological, legal, and operational capabilities. Lightweight sensor systems suitable for UAV platforms are being advertised in the trade literature at an ever-expanding rate with no standardization of system performance specifications or terms of reference. To address this issue, both the U.S. Geological Survey and the National Institute of Standards and Technology are eveloping draft standards to meet these issues. This paper presents the outline of a combined USGS/NIST cooperative strategy to develop and test a characterization methodology to meet the needs of a new and expanding UAV/CIS/HSI user community.

  13. Beryllium-beryllium oxide filter difference spectrometer

    Goldstone, J.A.; Eckert, J.; Taylor, A.D.; Wood, E.J.

    1982-06-01

    A successful experimental program has been initiated on the filter difference spectrometer. The instrument is most appropriate for energy transfers from about 50 to 600 MeV when moderate energy resolution is sufficient and a high count rate of importance. The difference technique is well enough understood so that peak positions, line widths and integrated intensities can be determined from fairly complex spectra. Several improvements to the instrument are in progress. An important change will be cooling of the sections which is expected to give approximately a factor of two increase in signal. The solid angle subtended by the detector banks will also be increased by a factor of 1.7 without significant degradation in resolution. With these improvements, much smaller samples can be examined in cases where material is unavailable in larger quantities, as well as samples with much small scattering cross sections. The major improvement will come when the proton storage ring becomes operational in 1985. A total increase of approximately 100 in neutrons detected will allow much more difficult experiments to be performed on this instrument with still a fast turnover rate

  14. The high-acceptance dielectron spectrometer HADES

    Agakichiev, G.; Destefanis, M.; Gilardi, C.; Kirschner, D.; Kuehn, W.; Lange, J.S.; Lehnert, J.; Lichtblau, C.; Lins, E.; Metag, V.; Mishra, D.; Novotny, R.; Pechenov, V.; Pechenova, O.; Perez Cavalcanti, T.; Petri, M.; Ritman, J.; Salz, C.; Schaefer, D.; Skoda, M.; Spataro, S.; Spruck, B.; Toia, A.; Agodi, C.; Coniglione, R.; Cosentino, L.; Finocchiaro, P.; Maiolino, C.; Piattelli, P.; Sapienza, P.; Vassiliev, D.; Alvarez-Pol, H.; Belver, D.; Cabanelas, P.; Castro, E.; Duran, I.; Fernandez, C.; Fuentes, B.; Garzon, J.A.; Kurtukian-Nieto, T.; Rodriguez-Prieto, G.; Sabin-Fernandez, J.; Sanchez, M.; Vazquez, A.; Atkin, E.; Volkov, Y.; Badura, E.; Bertini, D.; Bielcik, J.; Bokemeyer, H.; Dahlinger, M.; Daues, H.W.; Galatyuk, T.; Garabatos, C.; Gonzalez-Diaz, D.; Hehner, J.; Heinz, T.; Hoffmann, J.; Holzmann, R.; Koenig, I.; Koenig, W.; Kolb, B.W.; Kopf, U.; Lang, S.; Leinberger, U.; Magestro, D.; Muench, M.; Niebur, W.; Ott, W.; Pietraszko, J.; Rustamov, A.; Schicker, R.M.; Schoen, H.; Schoen, W.; Schroeder, C.; Schwab, E.; Senger, P.; Simon, R.S.; Stelzer, H.; Traxler, M.; Yurevich, S.; Zovinec, D.; Zumbruch, P.; Balanda, A.; Kozuch, A.; Przygoda, W.; Bassi, A.; Bassini, R.; Boiano, C.; Bartolotti, A.; Brambilla, S.; Bellia, G.; Migneco, E.; Belyaev, A.V.; Chepurnov, V.; Chernenko, S.; Fateev, O.V.; Ierusalimov, A.P.; Smykov, L.; Troyan, A.Yu.; Zanevsky, Y.V.; Benovic, M.; Hlavac, S.; Turzo, I.; Boehmer, M.; Christ, T.; Eberl, T.; Fabbietti, L.; Friese, J.; Gernhaeuser, R.; Gilg, H.; Homolka, J.; Jurkovic, M.; Kastenmueller, A.; Kienle, P.; Koerner, H.J.; Kruecken, R.; Maier, L.; Maier-Komor, P.; Sailer, B.; Schroeder, S.; Ulrich, A.; Wallner, C.; Weber, M.; Wieser, J.; Winkler, S.; Zeitelhack, K.; Boyard, J.L.; Genolini, B.; Hennino, T.; Jourdain, J.C.; Moriniere, E.; Pouthas, J.; Ramstein, B.; Rosier, P.; Roy-Stephan, M.; Sudol, M.; Braun-Munzinger, P.; Diaz, J.; Dohrmann, F.; Dressler, R.; Enghardt, W.; Heidel, K.; Hutsch, J.; Kanaki, K.; Kotte, R.; Naumann, L.; Sobiella, M.; Wuestenfeld, J.; Zhou, P.; Dybczak, A.; Jaskula, M.; Kajetanowicz, M.; Kidon, L.; Korcyl, K.; Kulessa, R.; Malarz, A.; Michalska, B.; Otwinowski, J.; Ploskon, M.; Prokopowicz, W.; Salabura, P.; Szczybura, M.; Trebacz, R.; Walus, W.; Wisniowski, M.; Wojcik, T.; Froehlich, I.; Lippmann, C.; Lorenz, M.; Markert, J.; Michel, J.; Muentz, C.; Pachmayer, Y.C.; Rosenkranz, K.; Stroebele, H.; Sturm, C.; Tarantola, A.; Teilab, K.; Wang, Y.; Zentek, A.; Golubeva, M.; Guber, F.; Ivashkin, A.; Karavicheva, T.; Kurepin, A.; Lapidus, K.; Reshetin, A.; Sadovsky, A.; Shileev, K.; Tiflov, V.; Grosse, E.; Kaempfer, B.; Iori, I.; Krizek, F.; Kugler, A.; Marek, T.; Novotny, J.; Pleskac, R.; Pospisil, V.; Sobolev, Yu.G.; Suk, M.; Taranenko, A.; Tikhonov, A.; Tlusty, P.; Wagner, V.; Mousa, J.; Parpottas, Y.; Tsertos, H.; Nekhaev, A.; Smolyankin, V.; Palka, M.; Roche, G.; Schmah, A.; Stroth, J.

    2009-01-01

    HADES is a versatile magnetic spectrometer aimed at studying dielectron production in pion, proton and heavy-ion-induced collisions. Its main features include a ring imaging gas Cherenkov detector for electron-hadron discrimination, a tracking system consisting of a set of 6 superconducting coils producing a toroidal field and drift chambers and a multiplicity and electron trigger array for additional electron-hadron discrimination and event characterization. A two-stage trigger system enhances events containing electrons. The physics program is focused on the investigation of hadron properties in nuclei and in the hot and dense hadronic matter. The detector system is characterized by an 85% azimuthal coverage over a polar angle interval from 18 to 85 , a single electron efficiency of 50% and a vector meson mass resolution of 2.5%. Identification of pions, kaons and protons is achieved combining time-of-flight and energy loss measurements over a large momentum range (0.1< p< 1.0 GeV/c). This paper describes the main features and the performance of the detector system. (orig.)

  15. Validation Tools for ATLAS Muon Spectrometer Commissioning

    Benekos, N.Chr.; Dedes, G.; Laporte, J.F.; Nicolaidou, R.; Ouraou, A.

    2008-01-01

    The ATLAS Muon Spectrometer (MS), currently being installed at CERN, is designed to measure final state muons of 14 TeV proton-proton interactions at the Large Hadron Collider (LHC) with a good momentum resolution of 2-3% at 10-100 GeV/c and 10% at 1 TeV, taking into account the high level background enviroment, the inhomogeneous magnetic field, and the large size of the apparatus (24 m diameter by 44 m length). The MS layout of the ATLAS detector is made of a large toroidal magnet, arrays of high-pressure drift tubes for precise tracking and dedicated fast detectors for the first-level trigger, and is organized in eight Large and eight Small sectors. All the detectors of the barrel toroid have been installed and the commissioning has started with cosmic rays. In order to validate the MS performance using cosmic events, a Muon Commissioning Validation package has been developed and its results are presented in this paper. Integration with the rest of the ATLAS sub-detectors is now being done in the ATLAS cavern

  16. The Polaris-H imaging spectrometer

    Wahl, Christopher G.; Kaye, Willy R.; Wang, Weiyi; Zhang, Feng; Jaworski, Jason M.; King, Alexis; Boucher, Y. Andy; He, Zhong

    2015-01-01

    Recently, H3D has designed and introduced a gamma-ray imaging spectrometer system named Polaris-H. Polaris-H was designed to perform gamma spectroscopy and imaging throughout nuclear power plants. It integrates a 3D-position-sensitive pixelated CZT detector (20 mm×20 mm×15 mm), associated readout electronics, an embedded computer, a 5-h battery, and an optical camera in a portable water-proof enclosure. The total mass is about 4 kg, and the system startup time is 2 min. Additionally, it has a connection for a tablet, which displays a gamma-ray spectrum and isotope-specific images of the gamma-ray distribution in all directions in real time. List-mode data is saved to an external USB memory stick. Based on pixelated depth-sensing technology, spectroscopy is routinely better than 1.1% FWHM at 662 keV, and imaging efficiency at 662 keV varies less than a factor of two for all directions, except through the battery. Measurements have been performed in contaminated environments, in high radiation fields, and in cramped quarters

  17. Perfluoroalkyl substances in waters along the Grand Canal, China.

    Piao, H T; Jiao, X C; Gai, N; Chen, S; Lu, G H; Yin, X C; Yamazaki, E; Yamashita, N; Tan, K Y; Yang, Y L; Pan, J

    2017-07-01

    The Grand Canal, also known as the Beijing-Hangzhou Grand Canal, is a UNESCO World Heritage Site and the longest canal in the world. It is an important trunk line of the South-to-North Water Diversion Project in China. The contamination status and spatial distributions of perfluoroalky substances (PFASs) in waters of the Grand Canal were investigated. The total concentrations of PFASs (∑PFASs) range from 7.8 ng/L to 218.0 ng/L, with high ∑PFASs occurring in the southern part of the Grand Canal which is located in a highly urbanized and economically developed region. The dominance of PFOA showed a decreasing trend toward north while shorter chain homologue proportions increased in the northern part of the Canal which mainly traverses underdeveloped and rural areas in Eastern China. Positive correlations were observed between ∑PFASs and the population density as well as GDP per capita. Intersection with large rivers may affect the contamination levels and composition of PFASs in the water of the Grand Canal near the intersection sites. Copyright © 2017 Elsevier Ltd. All rights reserved.

  18. Flocculent and grand design spiral galaxies in groups: time scales for the persistence of grand design spiral structures

    Elmegreen, B.G.; Elmegreen, D.M.

    1983-01-01

    Spiral arm classifications were made for 261 low-inclination galaxies in groups listed by Huchra and Geller. The fractional occurrence of grand design spiral structure in nonbarred galaxies was found to increase from approx.0.1 to approx.0.6 and then level off as the group crossing rate or galaxy collision rate in a group increases. A simple model is discussed where the random encounters between galaxies of any type and flocculent galaxies induce transient grand design spirals in the flocculent galaxies. If this grand-design stimulation occurs for binary collisions with impact parameters less than αR 25 , were R 25 is the galactic radius at 25 mag arcsec - 2 , and if the induced grand design spirals persist for an average time equal to #betta# galactic rotations, then the quantity α 2 #betta# equals approximately 3 x 10 4 . If binary collisions are responsible for grand design spirals, then this result implies either that the induced spirals last for many galactic rotations (#betta#>15), or that they can be stimulated by very remote encounters (α>45.) Alternatively, grand design spirals may be stimulated by multiple galaxy encounters, which would be the case for such large α, or by interactions with the potential well of the associated group, rather than by simple binary encounters. Weak correlations between the grand design fraction and the galaxy size, or between this fraction and the total number of galaxies in a group, were also found. Spiral structures of barred galaxies show no correlations with group environment

  19. Some conceptual designs for a LASSY spectrometer magnet

    Green, M.A.

    1995-09-01

    The LASSY spectrometer is a gas filled spectrometer (hydrogen or helium at a pressure of about 1 torr). The design bending power for the primary bending magnet for the spectrometer will have an induction bend radius product of 2.5 tesla-meters. In order to increase the acceptance of the spectrometer, the bending magnet system must be located close to the target where the desired nuclei are created. The spectrometer magnet system must consist of both bending and focusing elements so that the wide acceptance of particles can be brought to a focus at the analysis point that is down stream from the last magnet element. In order improve the spectrometer resolution and to catch the shortest lived nuclei, the length of the magnet system must be as short as possible. The length for the LASSY spectrometer magnet system from the target to the analysis point has been set at 2.5 meters or less. To improve the resolution of the spectrometer, the bending angle for bending magnet system must be increased to close to 180 degrees. In order to achieve a large bending angle and a short magnet system length, the bending induction must be above 3 tesla and the focusing elements must be combined with the bending elements. As a result, a LASSY spectrometer will have bending magnet with a bending angle from 140 to 170 degrees. This magnet win be combined with one or more focusing magnets (a straight dipole in some places and a combined function dipole in other places). The result is a single superconducting bending magnet with one or more quadrupoles incorporated within the large angle bending magnet

  20. SO(10) - Grand unification and fermion masses

    Oezer, A.D.

    2005-01-01

    In this work, we study SO(10) grand unification in its full extent by using different explicit matrix representations which exhibit the structure of SO(10) in a very transparent way. Our approach consists mainly of two stages: We derive the explicit expressions of the mass-eigenvalues and mass-eigenstates of the physical gauge bosons from a mass squared-matrix that contains all the information about the mixing parameters among the gauge fields and the phases which are sources for CP violation. In the light of this analysis, we derive the explicit expressions for the interaction Lagrangians of the charged currents, the neutral currents and the charged and colored currents in SO(10). We present explicit expressions of the vector and axial-vector couplings of the two neutral currents in SO(10). We show how the baryon, lepton and baryon minus lepton number violating processes and their explicit CP violating phases are accommodated in the SO(10) theory. The Higgs potential that we use to implement in the Higgs mechanism is constructed in a most general fashion through a careful study of the Higgs fields of SO(10), where we give special emphasis on illustrating the explicit matrix representation of these Higgs fields. The potential part of the Higgs Lagrangian will give us the properties of the minimum of the vacuum, and the kinetic part will give us the mass-squared matrix of the gauge bosons via spontaneous symmetry breakdown. The same Higgs multiplets will be coupled to fermions through a democratic Yukawa matrix. Thereby, we derive explicit expressions for the fermion masses of the third family including Majorana and Dirac masses for neutrinos. We introduce a flavor-eigenbasis for neutrinos and find the mass-eigenstates and mass-eigenvalues of the neutrinos. Explicit expressions for CP violation in the neutrino sector are obtained. In the second stage of our work, we evaluate all the above mentioned quantities. In addition, we present the values of the physical

  1. MESSENGER E/V/H GRNS 3 NEUTRON SPECTROMETER CDR V1.0

    National Aeronautics and Space Administration — Abstract ======== This data set consists of the MESSENGER Neutron Spectrometer (NS) calibrated data records (CDRs). The NS experiment is a neutron spectrometer...

  2. Evaluation of HOPG mounting possibilities for multiplexing spectrometers

    Groitl, Felix, E-mail: felix.groitl@psi.ch [Laboratory for Quantum Magnetism, École Polytechnique Fédérale de Lausanne, 1015 Lausanne (Switzerland); Laboratory for Neutron Scattering and Imaging, Paul Scherrer Institut, 5232 Villigen (Switzerland); Bartkowiak, Marek [Laboratory for Scientific Developments and Novel Materials, Paul Scherrer Institut, 5232 Villigen (Switzerland); Bergmann, Ryan M. [Division Large Research Facilities, Paul Scherrer Institut, 5232 Villigen (Switzerland); Birk, Jonas Okkels [Laboratory for Neutron Scattering and Imaging, Paul Scherrer Institut, 5232 Villigen (Switzerland); Department of Physics, Technical University of Denmark (DTU), 2800 Kgs. Lyngby (Denmark); Markó, Márton [Laboratory for Neutron Scattering and Imaging, Paul Scherrer Institut, 5232 Villigen (Switzerland); Wigner Research Centre for Physics, Neutron Spectroscopy Department, 1525 Budapest (Hungary); Bollhalder, Alex; Graf, Dieter [Laboratory for Scientific Developments and Novel Materials, Paul Scherrer Institut, 5232 Villigen (Switzerland); Niedermayer, Christof [Laboratory for Neutron Scattering and Imaging, Paul Scherrer Institut, 5232 Villigen (Switzerland); Rüegg, Christian [Laboratory for Neutron Scattering and Imaging, Paul Scherrer Institut, 5232 Villigen (Switzerland); Department of Quantum Matter Physics, University of Geneva, 1211 Geneva (Switzerland); Rønnow, Henrik M. [Laboratory for Quantum Magnetism, École Polytechnique Fédérale de Lausanne, 1015 Lausanne (Switzerland); Niels Bohr Institute, University of Copenhagen, 2100 Copenhagen (Denmark)

    2017-06-21

    Four different methods for mounting HOPG analyzer crystals on Si holders have been evaluated in the design process of the new multiplexing spectrometer CAMEA. Contrary to neutron optics used in standard spectrometers, the new instrument concept employs a series of analyzer segments behind each other where the neutrons have to pass through the bonding compound of the different analyzer crystals. The different methods, namely screws, shellac, indium soldering and clips, have been evaluated with regards to background, transmission, cooling, activation and handling. The results presented here will give valuable input for future CAMEA-type spectrometers currently planned and designed at various neutron sources.

  3. The development for small scale soft X-ray spectrometer

    Sun Kexu; Jiang Shaoen; Yi Rongqing; Cui Yanli

    2004-12-01

    For the development of small-scale soft X-ray spectrometer, first, some small-scale soft X-ray detection elements are developed, it is included GaAs irradiated with neutron, GaAs irradiated with proton, multi-layer mirror, plane mirror and small scale X-ray diode et al. Soft X-ray spectrometers built of multi-layer mirror-GaAs (with neutron irradiation), and plane mirror-small-scale XRD, and plane mirror-GaAs (with proton irradiation) are prepared. These spectrometers are examined in Shen Guang-II laser facility, and some external estimation are given. (authors)

  4. Inficon Transpector MPH Mass Spectrometer Random Vibration Test Report

    Santiago-Bond, Jo; Captain, Janine

    2015-01-01

    The purpose of this test report is to summarize results from the vibration testing of the INFICON Transpector MPH100M model Mass Spectrometer. It also identifies requirements satisfied, and procedures used in the test. As a payload of Resource Prospector, it is necessary to determine the survivability of the mass spectrometer to proto-qualification level random vibration. Changes in sensitivity of the mass spectrometer can be interpreted as a change in alignment of the instrument. The results of this test will be used to determine any necessary design changes as the team moves forward with flight design.

  5. Miniaturized NIR scanning grating spectrometer for use in mobile phones

    Knobbe, Jens; Pügner, Tino; Grüger, Heinrich

    2016-05-01

    An extremely miniaturized scanning grating spectrometer at the size of a sugar cube has been developed at Fraunhofer IPMS. To meet the requirements for the integration into a mobile phone a new system approach has been pursued. The key component within the system is a silicon-based deflectable diffraction grating with an integrated driving mechanism. A first sample of the new spectrometer was built and characterized. It was found to have a spectral range from 950 nm to 1900 nm at a resolution of 10 nm. The results show that the performance of the new MEMS spectrometer is in good agreement with the requirements for mobile phone integration.

  6. Opening the terahertz window on the OSIRIS spectrometer

    Demmel F.

    2015-01-01

    Full Text Available A cooled and mechanically retractable beryllium filter has been installed and commissioned on the low-energy OSIRIS spectrometer at ISIS. This instrument development extends the energy-transfer range of the spectrometer up to ca. 20 meV (∼ 5 THz, leading to an excellent resolution at THz frequencies and substantial gains in detected flux relative to existing capabilities on the neighbouring IRIS spectrometer. Herein, we provide a concise account of this new capability for high-resolution neutron spectroscopy in the THz domain, as well as outline a number of ongoing and potential scientific opportunities in condensed-matter physics, chemistry, and materials science.

  7. Setting up and performance of a laser enhanced ionisation spectrometer

    Chandola, L.C.; Khanna, P.P.; Razvi, M.A.N.

    1990-01-01

    A laser enhanced ionisation (LEI) spectrometer has been successfuly set up around an excimer laser pumped dye laser. The performance of the spectrometer has been tested by analysing sodium in water solutions. A straight line working curve has been obtained in the concentration range of 1-1000 ng/ml of Na. The effect of parameters like laser power, ion collector electrode voltage and the load resistance on LEI signals has been investigated. The spectrometer is useful not only for analytical purposes but also for laser spectroscopic studies of species formed in flames, study of phenomenon of combustion etc. (author). 1 tab ., 10 figs., 5 refs

  8. Design and Test of Portable Hyperspectral Imaging Spectrometer

    Chunbo Zou

    2017-01-01

    Full Text Available We design and implement a portable hyperspectral imaging spectrometer, which has high spectral resolution, high spatial resolution, small volume, and low weight. The flight test has been conducted, and the hyperspectral images are acquired successfully. To achieve high performance, small volume, and regular appearance, an improved Dyson structure is designed and used in the hyperspectral imaging spectrometer. The hyperspectral imaging spectrometer is suitable for the small platform such as CubeSat and UAV (unmanned aerial vehicle, and it is also convenient to use for hyperspectral imaging acquiring in the laboratory and the field.

  9. Liquid scintillation spectrometer survey 155Eu liquid activity

    Zhang Zuhua

    2002-01-01

    In the countrywide contrasting survey of 155 Eu activity, 155 Eu liquid activity was determined for the first time through using liquid scintillation spectrometer survey 155 Eu β ray. In survey total uncertainty, determining activity accord with determining activity average value of all a wide variety of survey instrument entering into contrasting survey. But using liquid scintillation spectrometer survey, it is simple and save time, is beyond compare for other survey method. It indicate liquid scintillation spectrometer survey β-γ nuclide activity is effective as well

  10. Evaluation of HOPG mounting possibilities for multiplexing spectrometers

    Groitl, Felix; Bartkowiak, Marek; Bergmann, Ryan M.; Birk, Jonas Okkels; Markó, Márton; Bollhalder, Alex; Graf, Dieter; Niedermayer, Christof; Rüegg, Christian; Rønnow, Henrik M.

    2017-01-01

    Four different methods for mounting HOPG analyzer crystals on Si holders have been evaluated in the design process of the new multiplexing spectrometer CAMEA. Contrary to neutron optics used in standard spectrometers, the new instrument concept employs a series of analyzer segments behind each other where the neutrons have to pass through the bonding compound of the different analyzer crystals. The different methods, namely screws, shellac, indium soldering and clips, have been evaluated with regards to background, transmission, cooling, activation and handling. The results presented here will give valuable input for future CAMEA-type spectrometers currently planned and designed at various neutron sources.

  11. Pulsed coherent spectrometer of nuclear magnetic and nuclear quadrupole resonance

    Karnachev, A.S.; Solov'ev, E.E.

    1996-01-01

    The spectrometer intended for studies on solid bodies was created on the basis of the X1-48 device for investigation of amplitude-frequency characteristics with the frequency range of 5-100 MHz, the receiver sensitivity by the signal-noise ratio at the outlet of 12 dB not worse than 0.5 μV and the feed-up capacity up to 80 W. The X1-48 minimal remodeling made it possible to use it in the spectrometer system as a signal feed-up source and measurer of the amplitude-frequency characteristic of the spectrometer receiver tract. 12 refs., 11 figs

  12. Biomechanical analysis technique choreographic movements (for example, "grand battman jete"

    Batieieva N.P.

    2015-04-01

    Full Text Available Purpose : biomechanical analysis of the execution of choreographic movement "grand battman jete". Material : the study involved students (n = 7 of the department of classical choreography faculty of choreography. Results : biomechanical analysis of choreographic movement "grand battman jete" (classic exercise, obtained kinematic characteristics (path, velocity, acceleration, force of the center of mass (CM bio parts of the body artist (foot, shin, thigh. Built bio kinematic model (phase. The energy characteristics - mechanical work and kinetic energy units legs when performing choreographic movement "grand battman jete". Conclusions : It was found that the ability of an athlete and coach-choreographer analyze the biomechanics of movement has a positive effect on the improvement of choreographic training of qualified athletes in gymnastics (sport, art, figure skating and dance sports.

  13. Liberating methodological thinking in human sciences from grand theories

    Kharlamov, Nikita; Baldursson, Einar Baldvin

    2016-01-01

    focus on the necessity of a “grand unified theory” at the expense of any and all alternative perspectives. Properties of grand theories are discussed on the examples of Giddens and Bourdieu. It is argued that grand theories hamper a more productive focus on concrete phenomena. Robert Merton’s focus......Many humanistic and social disciplines are naturally inclined to seek for human-, person-, self- centered focus, and develop a holistic theory of such. Such disciplines continually engage with philosophical, metaphysical and meta-theoretical perspectives. This engagement often leads to a singular...... on “middle range” theories is revisited and its continuing relevance is highlighted. The level of abstraction characteristic of such theories, as well as the way they engage with the empirical social reality, are discussed. The article concludes by considering the paradoxical reductionism that can...

  14. Environmental Audit of the Grand Junction Projects Office

    1991-08-01

    The Grand Junction Projects Office (GJPO) is located in Mesa County, Colorado, immediately south and west of the Grand Junction city limits. The US Atomic Energy Commission (AEC) established the Colorado Raw Materials Office at the present-day Grand Junction Projects Office in 1947, to aid in the development of a viable domestic uranium industry. Activities at the site included sampling uranium concentrate; pilot-plant milling research, including testing and processing of uranium ores; and operation of a uranium mill pilot plant from 1954 to 1958. The last shipment of uranium concentrate was sent from GJPO in January, 1975. Since that time the site has been utilized to support various DOE programs, such as the former National Uranium Resource Evaluation (NURE) Program, the Uranium Mill Tailings Remedial Action Project (UMTRAP), the Surplus Facilities Management Program (SFMP), and the Technical Measurements Center (TMC). All known contamination at GJPO is believed to be the result of the past uranium milling, analyses, and storage activities. Hazards associated with the wastes impounded at GJPO include surface and ground-water contamination and potential radon and gamma-radiation exposure. This report documents the results of the Baseline Environmental Audit conducted at Grand Junction Projects Office (GJPO) located in Grand Junction, Colorado. The Grand Junction Baseline Environmental Audit was conducted from May 28 to June 12, 1991, by the Office of Environmental Audit (EH-24). This Audit evaluated environmental programs and activities at GJPO, as well as GJPO activities at the State-Owned Temporary Repository. 4 figs., 12 tabs.

  15. Saturn's Internal Magnetic Field Revealed by Cassini Grand Finale

    Cao, H.; Dougherty, M. K.; Khurana, K. K.; Hunt, G. J.; Provan, G.; Kellock, S.; Burton, M. E.; Burk, T. A.

    2017-12-01

    Saturn's internal magnetic field has been puzzling since the first in-situ measurements during the Pioneer 11 Saturn flyby. Cassini magnetometer measurements prior to the Grand Finale phase established 1) the highly axisymmetric nature of Saturn's internal magnetic field with a dipole tilt smaller than 0.06 degrees, 2) at least an order of magnitude slower secular variation rate compared to that of the current geomagnetic field, and 3) expulsion of magnetic fluxes from the equatorial region towards high latitude. The highly axisymmetric nature of Saturn's intrinsic magnetic field not only challenges dynamo theory but also makes an accurate determination of the interior rotation rate of Saturn extremely difficult. The Cassini spacecraft entered the Grand Finale phase in April 2017, during which time the spacecraft dived through the gap between Saturn's atmosphere and the inner edge of the D-ring 22 times before descending into the deep atmosphere of Saturn. The unprecedented proximity to Saturn (reaching 2500 km above the cloud deck) and the highly inclined nature of the Grand Finale orbits provided an ideal opportunity to decode Saturn's internal magnetic field. The fluxgate magnetometer onboard Cassini made precise vector measurements during the Grand Finale phase. Magnetic signals from the interior of the planet, the magnetospheric ring current, the high-latitude field-aligned current (FAC) modulated by the 10.7 hour planetary period oscillation, and low-latitude FACs were observed during the Grand Finale phase. Here we report the magnetometer measurements during the Cassini Grand Finale phase, new features of Saturn's internal magnetic field revealed by these measurements (e.g., the high degree magnetic moments of Saturn, the level of axisymmetry beyond dipole), and implications for the deep interior of Saturn.

  16. Regional economic impacts of Grand Canyon river runners.

    Hjerpe, Evan E; Kim, Yeon-Su

    2007-10-01

    Economic impact analysis (EIA) of outdoor recreation can provide critical social information concerning the utilization of natural resources. Outdoor recreation and other non-consumptive uses of resources are viewed as environmentally friendly alternatives to extractive-type industries. While outdoor recreation can be an appropriate use of resources, it generates both beneficial and adverse socioeconomic impacts on rural communities. The authors used EIA to assess the regional economic impacts of rafting in Grand Canyon National Park. The Grand Canyon region of northern Arizona represents a rural US economy that is highly dependent upon tourism and recreational expenditures. The purpose of this research is twofold. The first is to ascertain the previously unknown regional economic impacts of Grand Canyon river runners. The second purpose is to examine attributes of these economic impacts in terms of regional multipliers, leakage, and types of employment created. Most of the literature on economic impacts of outdoor recreation has focused strictly on the positive economic impacts, failing to illuminate the coinciding adverse and constraining economic impacts. Examining the attributes of economic impacts can highlight deficiencies and constraints that limit the economic benefits of recreation and tourism. Regional expenditure information was obtained by surveying non-commercial boaters and commercial outfitters. The authors used IMPLAN input-output modeling to assess direct, indirect, and induced effects of Grand Canyon river runners. Multipliers were calculated for output, employment, and income. Over 22,000 people rafted on the Colorado River through Grand Canyon National Park in 2001, resulting in an estimated $21,100,000 of regional expenditures to the greater Grand Canyon economy. However, over 50% of all rafting-related expenditures were not captured by the regional economy and many of the jobs created by the rafting industry are lower-wage and seasonal. Policy

  17. Environmental Audit of the Grand Junction Projects Office

    1991-08-01

    The Grand Junction Projects Office (GJPO) is located in Mesa County, Colorado, immediately south and west of the Grand Junction city limits. The US Atomic Energy Commission (AEC) established the Colorado Raw Materials Office at the present-day Grand Junction Projects Office in 1947, to aid in the development of a viable domestic uranium industry. Activities at the site included sampling uranium concentrate; pilot-plant milling research, including testing and processing of uranium ores; and operation of a uranium mill pilot plant from 1954 to 1958. The last shipment of uranium concentrate was sent from GJPO in January, 1975. Since that time the site has been utilized to support various DOE programs, such as the former National Uranium Resource Evaluation (NURE) Program, the Uranium Mill Tailings Remedial Action Project (UMTRAP), the Surplus Facilities Management Program (SFMP), and the Technical Measurements Center (TMC). All known contamination at GJPO is believed to be the result of the past uranium milling, analyses, and storage activities. Hazards associated with the wastes impounded at GJPO include surface and ground-water contamination and potential radon and gamma-radiation exposure. This report documents the results of the Baseline Environmental Audit conducted at Grand Junction Projects Office (GJPO) located in Grand Junction, Colorado. The Grand Junction Baseline Environmental Audit was conducted from May 28 to June 12, 1991, by the Office of Environmental Audit (EH-24). This Audit evaluated environmental programs and activities at GJPO, as well as GJPO activities at the State-Owned Temporary Repository. 4 figs., 12 tabs

  18. THOR Ion Mass Spectrometer instrument - IMS

    Retinò, Alessandro; Kucharek, Harald; Saito, Yoshifumi; Fraenz, Markus; Verdeil, Christophe; Leblanc, Frederic; Techer, Jean-Denis; Jeandet, Alexis; Macri, John; Gaidos, John; Granoff, Mark; Yokota, Shoichiro; Fontaine, Dominique; Berthomier, Matthieu; Delcourt, Dominique; Kistler, Lynn; Galvin, Antoniette; Kasahara, Satoshi; Kronberg, Elena

    2016-04-01

    Turbulence Heating ObserveR (THOR) is the first mission ever flown in space dedicated to plasma turbulence. Specifically, THOR will study how turbulent fluctuations at kinetic scales heat and accelerate particles in different turbulent environments within the near-Earth space. To achieve this goal, THOR payload is being designed to measure electromagnetic fields and particle distribution functions with unprecedented resolution and accuracy. Here we present the Ion Mass Spectrometer (IMS) instrument that will measure the full three-dimensional distribution functions of near-Earth main ion species (H+, He+, He++ and O+) at high time resolution (~ 150 ms for H+ , ~ 300 ms for He++) with energy resolution down to ~ 10% in the range 10 eV/q to 30 keV/q and angular resolution ~ 10°. Such high time resolution is achieved by mounting multiple sensors around the spacecraft body, in similar fashion to the MMS/FPI instrument. Each sensor combines a top-hat electrostatic analyzer with deflectors at the entrance together with a time-of-flight section to perform mass selection. IMS electronics includes a fast sweeping high voltage board that is required to make measurements at high cadence. Ion detection includes Micro Channel Plates (MCP) combined with Application-Specific Integrated Circuits (ASICs) for charge amplification, discrimination and time-to-digital conversion (TDC). IMS is being designed to address many of THOR science requirements, in particular ion heating and acceleration by turbulent fluctuations in foreshock, shock and magnetosheath regions. The IMS instrument is being designed and will be built by an international consortium of scientific institutes with main hardware contributions from France, USA, Japan and Germany.

  19. Mass spectrometer calibration of Cosmic Dust Analyzer

    Ahrens, Thomas J.; Gupta, Satish C.; Jyoti, G.; Beauchamp, J. L.

    2003-02-01

    The time-of-flight (TOF) mass spectrometer (MS) of the Cosmic Dust Analyzer (CDA) instrument aboard the Cassini spacecraft is expected to be placed in orbit about Saturn to sample submicrometer-diameter ring particles and impact ejecta from Saturn's satellites. The CDA measures a mass spectrum of each particle that impacts the chemical analyzer sector of the instrument. Particles impact a Rh target plate at velocities of 1-100 km/s and produce some 10-8 to 10-5 times the particle mass of positive valence, single-charged ions. These are analyzed via a TOF MS. Initial tests employed a pulsed N2 laser acting on samples of kamacite, pyrrhotite, serpentine, olivine, and Murchison meteorite induced bursts of ions which were detected with a microchannel plate and a charge sensitive amplifier (CSA). Pulses from the N2 laser (1011 W/cm2) are assumed to simulate particle impact. Using aluminum alloy as a test sample, each pulse produces a charge of ~4.6 pC (mostly Al+1), whereas irradiation of a stainless steel target produces a ~2.8 pC (Fe+1) charge. Thus the present system yields ~10-5% of the laser energy in resulting ions. A CSA signal indicates that at the position of the microchannel plate, the ion detector geometry is such that some 5% of the laser-induced ions are collected in the CDA geometry. Employing a multichannel plate detector in this MS yields for Al-Mg-Cu alloy and kamacite targets well-defined peaks at 24 (Mg+1), 27(Al+1), and 64 (Cu+1) and 56 (Fe+1), 58 (Ni+1), and 60 (Ni+1) dalton, respectively.

  20. Cryogenic Scan Mechanism for Fourier Transform Spectrometer

    Brasunas, John C.; Francis, John L.

    2011-01-01

    A compact and lightweight mechanism has been developed to accurately move a Fourier transform spectrometer (FTS) scan mirror (a cube corner) in a near-linear fashion with near constant speed at cryogenic temperatures. This innovation includes a slide mechanism to restrict motion to one dimension, an actuator to drive the motion, and a linear velocity transducer (LVT) to measure the speed. The cube corner mirror is double-passed in one arm of the FTS; double-passing is required to compensate for optical beam shear resulting from tilting of the moving cube corner. The slide, actuator, and LVT are off-the-shelf components that are capable of cryogenic vacuum operation. The actuator drives the slide for the required travel of 2.5 cm. The LVT measures translation speed. A proportional feedback loop compares the LVT voltage with the set voltage (speed) to derive an error signal to drive the actuator and achieve near constant speed. When the end of the scan is reached, a personal computer reverses the set voltage. The actuator and LVT have no moving parts in contact, and have magnetic properties consistent with cryogenic operation. The unlubricated slide restricts motion to linear travel, using crossed roller bearings consistent with 100-million- stroke operation. The mechanism tilts several arc seconds during transport of the FTS mirror, which would compromise optical fringe efficiency when using a flat mirror. Consequently, a cube corner mirror is used, which converts a tilt into a shear. The sheared beam strikes (at normal incidence) a flat mirror at the end of the FTS arm with the moving mechanism, thereby returning upon itself and compensating for the shear

  1. Pequena monografia sobre o Rio Grande do Sul

    Ana Maria Pinho

    2014-05-01

    Full Text Available Pequena monografia desenvolvida por membros do Colégio Sevigne, que versa sobre diversos assuntos a respeito do Rio Grande do Sul, divididos em histórico, fronteiras, organização política administrativa, características geográficas, formação geomorfológica, economia, aspectos históricos e geográficos da capital do Estado, generalidades étnicas, e sobre o gaúcho em si. Grande quantidade de ilustrações e poemas enriquecem o artigo.

  2. Severe accident sequences simulated at the Grand Gulf Nuclear Station

    Carbajo, J.J.

    1999-01-01

    Different severe accident sequences employing the MELCOR code, version 1.8.4 QK, have been simulated at the Grand Gulf Nuclear Station (Grand Gulf). The postulated severe accidents simulated are two low-pressure, short-term, station blackouts; two unmitigated small-break (SB) loss-of-coolant accidents (LOCAs) (SBLOCAs); and one unmitigated large LOCA (LLOCA). The purpose of this study was to calculate best-estimate timings of events and source terms for a wide range of severe accidents and to compare the plant response to these accidents

  3. Grand Minima: Is The Sun Going To Sleep?

    Mcintosh, S. W.; Leamon, R. J.

    2014-12-01

    We explore recent observational work which indicate that the energetics of the sun's outer atmosphere have been on a steady decline for the past decade and perhaps longer. Futher, we show that new investigations into evolution of the Sun's global magnetic activity appear to demonstrate a path through which the Sun can go into, and exit from, a grand activity minimum without great difficulty while retaining an activity cycle - only losing sunspots. Are we at the begining of a new grand(-ish) minimum? Naturally, only time will tell, but the observational evidence hint that one may not be far off to what impact on the Sun-Earth Connection.

  4. Falares: a oralidade como elemento construtor da grande-reportagem

    Alex Criado

    2006-01-01

    Esta tese discute a incorporação da oralidade de falantes excluídos social e culturalmente na grande-reportagem. O foco desta pesquisa é refletir como a grande-reportagem no Brasil, em sua missão de desvendamento do real, tem lidado com a questão da oralidade. Discute os desafios para a incorporação dos registros orais de pessoas com baixa escolaridade, tendo em vista o preconceito que existe na sociedade em relação aos falantes que se utilizam de modalidades diferentes da língua padrão. Prop...

  5. Mitigation measures for the La Grande 1 hydroelectric development

    Faucher, O.; Gagnon, R.

    1992-01-01

    Measures to mitigate environmental impacts of the La Grande 1 hydroelectric development are described. An overview is presented of the La Grande 1 project, its surrounding environment, and the principle environmental repercussions of the reservoir, hydrological changes between the dam and river mouth, construction activities and permanent and temporary structures, and presence of workers. Mitigation measures including compensation, corrective measures (deforestation, selective cutting, fish populations, wildlife populations, land rehabilitation, access roads, fisheries, and erosion control), protective measures, enhancement measures, and contract and employment opportunities for the Cree population are described. 10 refs., 2 figs

  6. Guidebook to Rio Grande rift in New Mexico

    Hawley, J.W.

    1978-01-01

    Discusses the details of geologic features along the rift zone. Included are short papers on topics relative to the overall region. These papers and the road logs are of special interest to any one pursuing further study of the rift. This book is a comprehensive guide to the middle and late Cenozoic geology of the Rio Grande region of Colorado and New Mexico. Though initially used on field trips for the International Symposium on Tectonics and Magmatism of the Rio Grande rift, the guidebook will be useful to anyone interested in the Cenozoic history of the 600-mi-long area extending from central Colorado to El Paso, Texas.

  7. Moessbauer backscatter spectrometer with full data processing capability

    1976-01-01

    The design and operation of a Moessbauer backscatter spectrometer with full data processing capability is described, and the investigation of the applicability of this technique to a variety of practical metallurgical problems is discussed

  8. Compact High Performance Spectrometers Using Computational Imaging, Phase I

    National Aeronautics and Space Administration — Energy Research Company (ERCo), in collaboration with CoVar Applied Technologies, proposes the development of high throughput, compact, and lower cost spectrometers...

  9. Sensitivity and response time improvements in millimeter-wave spectrometers

    Kolbe, W.F.; Leskovar, B.

    1980-09-01

    A new version of a microwave spectrometer for the detection of gaseous pollutants and other atmospheric constituents is described. The spectrometer, which operates in the vicinity of 70 GHz, employs a Fabry-Perot resonator as a sample cell and uses superhetrodyne detection for high sensitivity. The spectrometer has been modified to incorporate a frequency doubler modulated at 30 MHz to permit operation with a single Gunn oscillator source. As a result, faster response time and somewhat greater sensitivity are obtained. The spectrometer is capable of detecting a minimum concentration of 1 ppM of SO 2 diluted in air with a 1 second time constant. For OCS diluted in air, the minimum detectable concentration is 800 ppB and with a 10 second time constant 300 ppB

  10. Improved kaon beam and spectrometer for the AGS

    Hungerford, E.V. III.

    1979-01-01

    The properties of the existing low energy separated kaon beams at the Brookhaven AGS, and the preliminary plans to construct an improved kaon beam line with a high resolution spectrometer for this facility are reported. 10 references

  11. Photoelectron spectrometer for attosecond spectroscopy of liquids and gases

    Jordan, I.; Huppert, M.; Wörner, H. J., E-mail: hwoerner@ethz.ch [Laboratory of Physical Chemistry, ETH Zurich, Vladimir-Prelog-Weg 2, 8093 Zurich (Switzerland); Brown, M. A. [Laboratory for Surface Science and Technology, Department of Materials, ETH Zurich, Vladimir-Prelog-Weg 5, 8093 Zurich (Switzerland); Bokhoven, J. A. van [Institute for Chemical and Bioengineering, ETH Zurich, Vladimir-Prelog-Weg 1, 8093 Zurich (Switzerland); Laboratory for Catalysis and Sustainable Chemistry, Paul Scherrer Institute, 5232 Villigen (Switzerland)

    2015-12-15

    A new apparatus for attosecond time-resolved photoelectron spectroscopy of liquids and gases is described. It combines a liquid microjet source with a magnetic-bottle photoelectron spectrometer and an actively stabilized attosecond beamline. The photoelectron spectrometer permits venting and pumping of the interaction chamber without affecting the low pressure in the flight tube. This pressure separation has been realized through a sliding skimmer plate, which effectively seals the flight tube in its closed position and functions as a differential pumping stage in its open position. A high-harmonic photon spectrometer, attached to the photoelectron spectrometer, exit port is used to acquire photon spectra for calibration purposes. Attosecond pulse trains have been used to record photoelectron spectra of noble gases, water in the gas and liquid states as well as solvated species. RABBIT scans demonstrate the attosecond resolution of this setup.

  12. FERDO/FERD, Unfolding of Pulse-Height Spectrometer Spectra

    Rust, B.W.; Ingersoll, D.T.; Burrus, W.R.

    1985-01-01

    1 - Description of problem or function: FERDO and FERD are unfolding codes which can be used to correct observed pulse-height distributions for the non-ideal response of a pulse-height spectrometer or to solve poorly conditioned linear equations. 2 - Method of solution: It is assumed that the response of the spectrometer is given by Ax = b, where A is the spectrometer response function matrix, x is the unknown spectrum, and b is the pulse-height distribution. FERDO does not resolve directly for x but instead solves for p = Wx, where W is a 'window function matrix'. Typically, W is the resolution function of an ideal spectrometer which has a single Gaussian response. The effective resolution of the unfolding solution may be varied by the choice of W. Confidence intervals are found for each element of the solution p

  13. Development of a cosmic veto gamma-spectrometer

    Burnett, J.L.; Davies, A.V.

    2012-01-01

    Cosmic radiation contributes significantly towards the background radiation measured by a gamma-spectrometer. A novel cosmic veto gamma-spectrometer has been developed that provides a mean background reduction of 54.5%. The system consists of plastic scintillation plates operated in time-stamp mode to detect coincident muon interactions within an HPGe gamma-spectrometer. The instrument is easily configurable and provides improved sensitivity for radionuclides indicative of nuclear weapons tests and reactor incidents, including 140 Ba, 95 Zr, 99 Mo, 141 Ce, 147 Nd, 131 I, 134 Cs and 137 Cs. This has been demonstrated for Comprehensive Nuclear-Test-Ban Treaty applications to obtain the required 140 Ba MDA of 24 mBq within 2 days counting. Analysis of an air filter sample collected during the Fukushima incident indicates improved sensitivity compared to conventional gamma-spectrometers. (author)

  14. Field microcomputerized multichannel γ ray spectrometer based on notebook computer

    Jia Wenyi; Wei Biao; Zhou Rongsheng; Li Guodong; Tang Hong

    1996-01-01

    Currently, field γ ray spectrometry can not rapidly measure γ ray full spectrum, so a field microcomputerized multichannel γ ray spectrometer based on notebook computer is described, and the γ ray full spectrum can be rapidly measured in the field

  15. Miniature Mass Spectrometer for Earth Science Research, Phase I

    National Aeronautics and Space Administration — By drastically reducing the physical footprint of a mass spectrometer to the size of a beverage can, Ceramitron could set a new performance/price standard in the...

  16. Photoelectron spectrometer for attosecond spectroscopy of liquids and gases

    Jordan, I.; Huppert, M.; Wörner, H. J.; Brown, M. A.; Bokhoven, J. A. van

    2015-01-01

    A new apparatus for attosecond time-resolved photoelectron spectroscopy of liquids and gases is described. It combines a liquid microjet source with a magnetic-bottle photoelectron spectrometer and an actively stabilized attosecond beamline. The photoelectron spectrometer permits venting and pumping of the interaction chamber without affecting the low pressure in the flight tube. This pressure separation has been realized through a sliding skimmer plate, which effectively seals the flight tube in its closed position and functions as a differential pumping stage in its open position. A high-harmonic photon spectrometer, attached to the photoelectron spectrometer, exit port is used to acquire photon spectra for calibration purposes. Attosecond pulse trains have been used to record photoelectron spectra of noble gases, water in the gas and liquid states as well as solvated species. RABBIT scans demonstrate the attosecond resolution of this setup

  17. Photoelectron spectrometer for attosecond spectroscopy of liquids and gases

    Jordan, I.; Huppert, M.; Brown, M. A.; van Bokhoven, J. A.; Wörner, H. J.

    2015-12-01

    A new apparatus for attosecond time-resolved photoelectron spectroscopy of liquids and gases is described. It combines a liquid microjet source with a magnetic-bottle photoelectron spectrometer and an actively stabilized attosecond beamline. The photoelectron spectrometer permits venting and pumping of the interaction chamber without affecting the low pressure in the flight tube. This pressure separation has been realized through a sliding skimmer plate, which effectively seals the flight tube in its closed position and functions as a differential pumping stage in its open position. A high-harmonic photon spectrometer, attached to the photoelectron spectrometer, exit port is used to acquire photon spectra for calibration purposes. Attosecond pulse trains have been used to record photoelectron spectra of noble gases, water in the gas and liquid states as well as solvated species. RABBIT scans demonstrate the attosecond resolution of this setup.

  18. Description of the double Compton spectrometer at Mayence MPI

    Borchert, H.; Ziegler, B.; Gimm, H.; Zieger, A.; Hughes, R.J.; Ahrens, J.

    1977-01-01

    The double Compton spectrometer of the Laboratories of the Mayence Linear Accelerator consists in two identical magnetic spectrometers, in which the electron scattered forwards by photons through a Compton process, are detected. The spectrometers have been built to detect 10-350 MeV photons and, as they involve thin Compton targets, their effect on the photon flux is negligible. They are put in cascade inside a well collimated bremsstrahlung beam. A thick absorbing target (max. thickness 2m) can be inserted inside the beam. The facility is outlined, some special properties of the accelerator and the bremsstrahlung beam are given. The properties of a Compton spectrometer involving eleven detectors are given by eleven response functions giving the relations between the photon flux impinging the Compton target and the counting rates of the detectors for a given adjustment of the magnets. A Monte-Carlo method is used for the calculation together with analytical methods neglecting the multiple scattering effects [fr

  19. Effect of jitter on an imaging FTIR spectrometer

    Bennett, C. L., LLNL

    1997-04-01

    Line of sight (LOS) jitter produces temporal modulations of the signals which are detected in the focal plane of a temporally modulated imaging Fourier Transform Spectrometer. A theoretical treatment of LOS jitter effects is given, and is compared with the results of measurements with LIFTIRS1 (the Livermore Imaging Fourier Transform InfraRed Spectrometer). The identification, isolation, quantification and removal of jitter artifacts in hyperspectral imaging data by means of principal components analysis is discussed. The theoretical distribution of eigenvalues expected from principal components analysis is used to determine the level of significance of spatially coherent instrumental artifacts in general, including jitter as a representative example. It is concluded that an imaging FTIR spectrometer is much less seriously impacted by a given LOS jitter level than a non imaging FTIR spectrometer.

  20. The University of Colorado OSO-8 spectrometer experiment. I

    Bruner, E.C. Jr.

    1977-01-01

    The optical design of the high resolution ultraviolet spectrometer prepared for the OSO-8 spacecraft by the University of Colorado is discussed. The instrument is a conventional 1 m Ebert-Fastie spectrometer fed by a Cassegrainian telescope. The instrument operates in the spectral range 1200 A to about 2000 A with spectral resolution of order 0.02 A. Spatial resolution is about 2.5 sec normal to the direction of the slit and is selectable from about 3 sec to 15' along the direction of the slit. Time resolution for the single spectrometer channel is selectable according to the needs of an individual observation and is limited to a maximum sampling rate of 40 ms per data point. The instrument is controlled by an internal general purpose computer. In this paper the author develops the performance requirements of the spectrometer and attempts to highlight some of the tradeoffs available to the instrument designer. (Auth.)