WorldWideScience

Sample records for graft insertion modern

  1. Rectus femoris muscle flap based on proximal insertion mobilization to cover a groin infected vascular graft.

    Science.gov (United States)

    Silvestre, Luís; Pedro, Luís Mendes; Fernandes e Fernandes, Ruy; Silva, Emanuel; Fernandes e Fernandes, José

    2015-10-01

    The rectus femoris (RF) muscle flap, which is widely used to cover groin infected vascular grafts, is usually harvested through distal tendon division and an extensive muscle elevation and transposition into the groin wound defect. A case of a vascular prosthetic graft infection in the groin was successfully controlled after coverage with an RF flap that was harvested based on proximal portion mobilization instead of the conventional distal one. This case suggests that the RF muscle flap based on proximal insertion mobilization is a feasible, effective, technically simpler, and less invasive alternative to cover infected vascular grafts in the groin. Copyright © 2015 Society for Vascular Surgery. Published by Elsevier Inc. All rights reserved.

  2. Influence of pleural drain insertion in lung function of patients undergoing coronary artery bypass grafting.

    Science.gov (United States)

    Ozelami Vieira, Irinea Beatriz Carvalho; Vieira, Fabiano F; Abrão, João; Gastaldi, Ada Clarice

    2012-01-01

    Longitudinal, prospective, randomized, blinded Trial to assess the influence of pleural drain (non-toxic PVC) site of insertion on lung function and postoperative pain of patients undergoing coronary artery bypass grafting in the first three days post-surgery and immediately after chest tube removal. Thirty six patients scheduled for elective myocardial revascularization with cardiopulmonary bypass (CPB) were randomly allocated into two groups: SX group (subxiphoid) and IC group (intercostal drain). Spirometry, arterial blood gases, and pain tests were recorded. Thirty one patients were selected, 16 in SX group and 15 in IC group. Postoperative (PO) spirometric values were higher in SX than in IC group (ppleural drain location on breathing. PaO(2) on the second PO increased significantly in SX group compared with IC group (pDrain with insertion in the subxiphoid region causes less change in lung function and discomfort, allowing better recovery of respiratory parameters. Copyright © 2012 Elsevier Editora Ltda. All rights reserved.

  3. Graft-free Ahmed tube insertion: a modified method at 5 mm from limbus

    Directory of Open Access Journals (Sweden)

    Juan Carlos Mesa-Gutiérrez

    2010-04-01

    Full Text Available Juan Carlos Mesa-Gutiérrez, Juan Lillo-Sopena, Anna Monés-Llivina, Silvia Sanz-Moreno, Jorge Arruga-GinebredaDepartment of Ophthalmology, Hospital Universitari de Bellvitge, L’Hospitalet de Llobregat, Barcelona, SpainObjective: To determine the medium-term outcome of Ahmed implants inserted through a needle tract at 5 mm from limbus that eliminates the need for a donor scleral graft.Methods: A retrospective case series of 19 patients undergoing Ahmed implant surgery for refractory glaucoma with a mean follow-up of 12 months. Primary outcome measures included control of intraocular pressure after surgery. Secondary outcome measure included the frequency of intraoperative and postoperative complications.Results: Intraocular pressure was maintained between 6 and 21 mmHg throughout the study. There was no postoperative hypotony. There were no complications related to this modified technique.Conclusion: Needle tract at 5 mm from limbus maintains implant’s ability to control intraocular pressure and eliminates the need for a donor scleral graft or heterologous material.Keywords: surgical technique, Ahmed implant, refractory glaucoma, donor scleral graft, tube shunt device

  4. Nature or Artifice? Grafting in Early Modern Surgery and Agronomy.

    Science.gov (United States)

    Savoia, Paolo

    2017-01-01

    In 1597, Gaspare Tagliacozzi published a famous two-volume book on “plastic surgery.” The reconstructive technique he described was based on grafting skin taken from the arm onto the mutilated parts of the patient's damaged face – especially noses. This paper focuses on techniques of grafting, the “culture of grafting,” and the relationships between surgery and plant sciences in the sixteenth century. By describing the fascination with grafting in surgery, natural history, gardening, and agronomy the paper argues that grafting techniques were subject to delicate issues: to what extent it was morally acceptable to deceive the eye with artificial entities? and what was the status of the product of a surgical procedure that challenged the traditional natural/artificial distinction? Finally, this paper shows how in the seventeenth century grafting survived the crisis of Galenism by discussing the role it played in teratology and in controversies on the uses the new mechanistic anatomy.

  5. Detection of mitochondrial insertions in the nucleus (NuMts of Pleistocene and modern muskoxen

    Directory of Open Access Journals (Sweden)

    MacPhee Ross DE

    2007-04-01

    Full Text Available Abstract Background Nuclear insertions of mitochondrial sequences (NuMts have been identified in a wide variety of organisms. Trafficking of genetic material from the mitochondria to the nucleus has occurred frequently during mammalian evolution and can lead to the production of a large pool of sequences with varying degrees of homology to organellar mitochondrial DNA (mtDNA sequences. This presents both opportunities and challenges for forensics, population genetics, evolutionary genetics, conservation biology and the study of DNA from ancient samples. Here we present a case in which difficulties in ascertaining the organellar mtDNA sequence from modern samples hindered their comparison to ancient DNA sequences. Results We obtained mitochondrial hypervariable region (HVR sequences from six ancient samples of tundra muskox (Ovibos moschatus that were reproducible but distinct from modern muskox sequences reported previously. Using the same PCR primers applied to the ancient specimens and the primers used to generate the modern muskox DNA sequences in a previous study, we failed to definitively identify the organellar sequence from the two modern muskox samples tested. Instead of anticipated sequence homogeneity, we obtained multiple unique sequences from both hair and blood of one modern specimen. Sequencing individual clones of a >1 kb PCR fragment from modern samples did not alleviate the problem as there was not a consistent match across the entire length of the sequences to Ovibos when compared to sequences in GenBank. Conclusion In specific taxa, due to nuclear insertions some regions of the mitochondrial genome may not be useful for the characterization of modern or ancient DNA.

  6. Real-time assessment of corneal endothelial cell damage following graft preparation and donor insertion for DMEK.

    Directory of Open Access Journals (Sweden)

    Maninder Bhogal

    Full Text Available To establish a method for assessing graft viability, in-vivo, following corneal transplantation.Optimization of calcein AM fluorescence and toxicity assessment was performed in cultured human corneal endothelial cells and ex-vivo corneal tissue. Descemet membrane endothelial keratoplasty grafts were incubated with calcein AM and imaged pre and post preparation, and in-situ after insertion and unfolding in a pig eye model. Global, macroscopic images of the entire graft and individual cell resolution could be attained by altering the magnification of a clinical confocal scanning laser microscope. Patterns of cell loss observed in situ were compared to those seen using standard ex-vivo techniques.Calcein AM showed a positive dose-fluorescence relationship. A dose of 2.67μmol was sufficient to allow clear discrimination between viable and non-viable areas (sensitivity of 96.6% with a specificity of 96.1% and was not toxic to cultured endothelial cells or ex-vivo corneal tissue. Patterns of cell loss seen in-situ closely matched those seen on ex-vivo assessment with fluorescence viability imaging, trypan blue/alizarin red staining or scanning electron microscopy. Iatrogenic graft damage from preparation and insertion varied between 7-35% and incarceration of the graft tissue within surgical wounds was identified as a significant cause of endothelial damage.In-situ graft viability assessment using clinical imaging devices provides comparable information to ex-vivo methods. This method shows high sensitivity and specificity, is non-toxic and can be used to evaluate immediate cell viability in new grafting techniques in-vivo.

  7. Association of Angiotensin-Converting Enzyme Genotype, Insertion/Deletion Polymorphism and Saphenous Vein Graft Atherosclerosis in Iranian Patients

    Directory of Open Access Journals (Sweden)

    Neda Zeinali

    2015-10-01

    Full Text Available ABSTRACT OBJECTIVE: The aim of this study was to evaluate possible interactions among Angiotensin-I converting enzyme genotype, insertion/deletion polymorphism and atherosclerosis of vein grafts in Iranian patients, and characterize their clinical and demographic profile. METHODS: In this cross-sectional study, patients who underwent coronary artery bypass graft surgery more than five years ago, were included for angiographic analysis. Atherosclerosis was determined by quantitative angiography and adjusted Gensini score. The gene angiotensin converting enzyme I/D polymorphism was detected by polymerase chain reaction. RESULTS: A total of 102 patients participated in this study. Eighty-four patients were male. The frequency distribution of DD, ID and II polymorphism were 23.6%, 62.7% and 13.7% respectively. There were no differences among genotypic groups in age, sex, number of risk factors, number of vein grafts and months since bypass surgery. According to adjusted Gensini score [0.18±0.12 (II vs. 0.11±0.09 (ID and 0.1±0.09 (DD P=0.021] the II genotype was associated with severity of vein graft atherosclerosis. CONCLUSION: Although there are conflicting results about gene angiotensin converting enzyme I/D polymorphism and the degree of venous bypass graft degeneration, this study suggests an association between ACE genotype II and atherosclerosis of saphenous vein grafts, however, large samples considering clinical, demographic and ethnic profile are necessary to confirm these results.

  8. Insertion of Contemporary and Modern Physics in classroom: a teaching learning sequence on radioactivity

    Directory of Open Access Journals (Sweden)

    Carlos Alexandre dos Santos Batista

    2017-12-01

    Full Text Available After more than two decades of justifications on the insertion of Modern and Contemporary Physics in the high school Education, the current challenge regards to how this content can be inserted in the classroom in an interesting and innovative way. Recent research reveals that despite a significant accumulation of recent academic research, whose purpose is to assist teachers pedagogically, few are grounded and proposed theoretically seeking to investigate how this integration happens. In this sense, we present a teaching-learning sequence on the topic of radioactivity, forged in the theoretical and methodological assumptions of Design-Based Research and a Teaching-Learning Sequence that, when implemented in public schools in the south of Bahia, produced the relevant knowledge to be shared with the community on teaching physics. Forged in our assumptions, the proposal allows teachers and researchers to understand questions about how, when and why, in fact, the inclusion of Modern and Contemporary Physics can occur in a non-traditional way. Therefore, the importance of this proposal is revealed to the high school of physics as it translates its ability to transform the theoretical demands on the curriculum and methodological innovation in the practical interventions in the classroom. We add that the availability of the necessary sources to find lesson plans, quizzes, texts, videos of teaching-learning sequence, shows the contribution of this work for teachers and researchers, in particular, to improve the scientific learning of students in the Basic Education.

  9. External wire-frame fixation of digital skin grafts: a non-invasive alternative to the K-wire insertion method.

    Science.gov (United States)

    Huang, Chenyu; Ogawa, Rei; Hyakusoku, Hiko

    2014-08-01

    The current skin graft fixation methods for digits, including the Kirschner wire insertion technique, can be limited by inadequate or excessive fixation and complications such as infection or secondary injuries. Therefore, the external wire-frame fixation method was invented and used for skin grafting of digits. This study aimed to investigate external wire-frame fixation of digital skin grafts as a non-invasive alternative to the K-wire insertion method. In 2005-2012, 15 patients with burn scar contractures on the hand digits received a skin graft that was then fixed with an external wire frame. The intra-operative time needed to make the wire frame, the postoperative time to frame and suture removal, the graft survival rate, the effect of contracture release and the complications were recorded. In all cases, the contracture release was 100%. The complete graft survival rate was 98.6%. Four patients had epithelial necrosis in wire-frame fixation is simple, minimally invasive and a custom-made technique for skin grafting of the fingers. It was designed for its potential benefits and the decreased risk it poses to patients with scar contractures on their fingers. It can be implemented in three phases of grafting, does not affect the epiphyseal line or subsequent finger growth and is suitable for children with multi-digit involvement. Copyright © 2013 Elsevier Ltd and ISBI. All rights reserved.

  10. Development of an abdominal aortic aneurysm model for stent-graft insertion

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Tae Hyung; Lee, Jong Heon; Shin, Dong Ik; Sung, Kyu Bo; Ko, Gi Young; Lim, Jin Oh [College of Medicine, Univ. of Ulsan, Seoul (Korea, Republic of); Kim, Si Hoon [S and G Biotech Research Institute, Seoul (Korea, Republic of)

    2002-03-01

    To determine the efficacy of an abdominal aortic aneurysm model for stent-graft placement. The model consists of two parts, the heart and the vascular system. A peristaltic pump and a solenoid valve were used to simulate a pulsatile flow from the heart. A ball-shaped piece of clay was placed inside a square box and liquid silicone was poured. After the silicone was formed, the clay was removed and a silicone tube was used to connect the heart model and the aneurysm model. The silicone tube was also used to simulate the iliac arteries and one end of the artery was clampled and the other one was extended to water bath. Water at 37 .deg. C was circulated through the model, and the pressure at the thoracic aorta, aneurysm and iliac artery was measured with the outlet valve opening at 25, 50, and 100% before and after stent-graft placement. The liquid pressure measurements were 253/252, 271/162 and 264/166 mmHg at the thoracic aorta, aneurysm and iliac artery, respectively, when the outlet was 100% open. They were 173/121, 145/99, 145/106 mmHg when the outlet was 50% open, and 35/28, 61/44, 24/22 mmHg when it was 25% open. After placement of the stent-graft, the pressure measurements were 170/128, and 167/128 mmHg, respectively. Since it was easy to produce, the model was useful for in-vitro stent-graft testing, and a wide range of pressure could be applied.

  11. Grafting

    Energy Technology Data Exchange (ETDEWEB)

    Garnett, J L [New South Wales Univ., Kensington (Australia). School of Chemistry

    1979-01-01

    The unique value of ionizing radiation for the initiation of grafting to backbone polymers is discussed. The principles of the technique are briefly reviewed. The conditions under which free radicals and ions participate in these reactions are examined. Examples of representative grafting processes are considered to illustrate where the technique can be of potential commercial value to a wide range of industries. The general principles of these grafting reactions are shown to be applicable to radiation induced rapid cure technology such as is provided by electron beam processing facilities. Grafting reactions initiated by UV are also treated and shown to be of importance because of the many similarities in properties of the ionizing radiation and UV systems, also the rapid industrial exploitation of EB and sensitized UV processing technology. Possible future trends in radiation grafting are outlined.

  12. Efficacy of cardiac resynchronization with defibrillator insertion in patients undergone coronary artery bypass graft: A cohort study of cardiac function

    Directory of Open Access Journals (Sweden)

    Reza Karbasi Afshar

    2015-01-01

    Full Text Available Introduction: Cardiac resynchronization therapy (CRT is a proven therapeutic method in selected patients with heart failure and systolic dysfunction which increases left ventricular function and patient survival. We designed a study that included patients undergoing coronary artery bypass graft (CABG, with and without CRT-defibrillator (CRT-D inserting and then measured its effects on these two groups. Patients and Methods: Between 2010 and 2013, we conducted a prospective cohort study on 100 coronary artery disease patients where candidate for CABG. Then based on the receiving CRT-D, the patients were categorized in two groups; Group 1 ( n = 48, with CRT-D insertion before CABG and Group 2 ( n = 52 without receiving CRT-D. Thereafter both of these groups were followed-up at 1-3 months after CABG for mortality, hospitalization, atrial fibrillation (AF, echocardiographic assessment, and New York Heart Association (NYHA class level. Results: The mean age of participants in Group 1 (48 male and in Group 2 (52 male was 58 ± 13 and 57 ± 12 respectively. Difference between Groups 1 and 2 in cases of mean left ventricular ejection fraction (LVEF changes and NYHA class level was significant ( P > 0.05. Hospitalization ( P = 0.008, mortality rate ( P = 0.007, and AF were significantly different between these two groups. Conclusions: The results showed that the increase in LVEF and patient′s improvement according to NYHA-class was significant in the first group, and readmission, mortality rate and AF was increased significantly in the second group.

  13. Modern

    Directory of Open Access Journals (Sweden)

    A.V. Bagrov

    2014-06-01

    Full Text Available The article gives an overview of the most important problems of modern meteoric astronomy and briefly describes ways and methods of their solutions. Particular attention is paid to the construction and arrangement of meteoric video cameras intended for registration of the meteoric phenomena as the main method of obtaining reliable and objective observational data on the basis of which the solution of the described tasks is possible.

  14. Association of elevated pretransplant sCD30 levels with graft loss in 206 patients treated with modern immunosuppressive therapies after renal transplantation.

    Science.gov (United States)

    Heinemann, Falko M; Rebmann, Vera; Witzke, Oliver; Philipp, Thomas; Broelsch, Christoph E; Grosse-Wilde, Hans

    2007-03-27

    Recent reports suggest that high pretransplant serum levels of soluble CD30 (sCD30) are a risk factor for rejections after kidney transplantation. The aim of our study was to elucidate the predictive value of pretransplant sCD30 levels for kidney transplantation outcome in a single-center patient cohort that has been treated with modern immunosuppressive therapies after transplantation. We retrospectively analyzed sCD30 in multiple pretransplant sera from 206 patients, of whom 174 were transplanted with a cadaveric kidney and 32 patients received an allograft from a living donor. Renal function after transplantation was estimated by measuring serum creatinine and by rejection diagnosis. We could demonstrate a statistically significant association between increased pretransplant sCD30 values and graft failures (P=0.005). Receiver operating curve analysis revealed a cutoff value of 124 U/mL pretransplant sCD30. A multivariate analysis confirmed pretransplant sCD30 values >124 U/mL (P=0.011) and rejection episodes (PsCD30 levels and the incidence of graft failure, but we could not confirm that the development of rejection episodes is correlated with pretransplant sCD30 values.

  15. Application of modern computer-aided technologies in the production of individual bone graft: A case report

    Directory of Open Access Journals (Sweden)

    Mirković Siniša

    2015-01-01

    Full Text Available Introduction. An autologous bone (bone derived from the patient himself is considered to be a “golden standard” in the treatment of bone defects and partial atrophic alveolar ridge. However, large defects and bone losses are difficult to restore in this manner, because extraction of large amounts of autologous tissue can cause donor-site problems. Alternatively, data from computed tomographic (CT scan can be used to shape a precise 3D homologous bone block using a computer-aided design-computer-aided manufacturing (CAD-CAM system. Case report. A 63-year old male patient referred to the Clinic of Dentistry of Vojvodina in Novi Sad, because of teeth loss in the right lateral region of the lower jaw. Clinical examination revealed a pronounced resorption of the residual ridge of the lower jaw in the aforementioned region, both horizontal and vertical. After clinical examination, the patient was referred for 3D cone beam (CBCT scan that enables visualization of bony structures and accurate measurement of dimensions of the residual alveolar ridge. Considering the large extent of bone resorption, the required ridge augmentation was more than 3 mm in height and 2 mm in width along the length of some 2 cm, thus the use of granular material was excluded. After consulting prosthodontists and engineers from the Faculty of Technical Sciences in Novi Sad we decided to fabricate an individual (custom bovine-derived bone graft designed according to the obtained 3D CBCT scan. Conclusion. Application of 3D CBCT images, computer-aided systems and software in manufacturing custom bone grafts represents the most recent method of guided bone regeneration. This method substantially reduces time of recovery and carries minimum risk of postoperative complications, yet the results fully satisfy the requirements of both the patient and the therapist.

  16. Implant angulation: 2-year retrospective analysis on the influence of dental implant angle insertion on marginal bone resorption in maxillary and mandibular osseous onlay grafts.

    Science.gov (United States)

    Ramaglia, Luca; Toti, Paolo; Sbordone, Carolina; Guidetti, Franco; Martuscelli, Ranieri; Sbordone, Ludovico

    2015-05-01

    The purpose of this study was to determine the existence of correlations between marginal peri-implant linear bone loss and the angulation of implants in maxillary and mandibular augmented areas over the course of a 2-year survey. Dependent variables described the sample of the present retrospective chart review. By using three-dimensional radiographs, input variables, describing the implant angulation (buccal-lingual angle [φ] and mesial-distal angle [θ]) were measured; outcome variables described survival rate and marginal bone resorption (MBR) around dental implants in autogenous grafts (10 maxillae and 14 mandibles). Pairwise comparisons and linear correlation coefficient were computed. The peri-implant MBR in maxillary buccal and palatal areas appeared less intensive in the presence of an increased angulation of an implant towards the palatal side. Minor MBR was recorded around mandibular dental implants positioned at a right angle and slightly angulated towards the mesial. Resorption in buccal areas may be less intensive as the angulation of placed implants increases towards the palatal area in the maxilla, whereas for the mandible, a greater inclination towards the lingual area could be negative. In the mandibular group, when the implant was slightly angulated in the direction of the distal area, bone resorption seemed to be more marked in the buccal area. In the planning of dental implant placement in reconstructed alveolar bone with autograft, the extremely unfavourable resorption at the buccal aspect should be considered; this marginal bone loss seemed to be very sensitive to the angulation of the dental implant.

  17. Non-imaging assisted insertion of un-cuffed, non-tunneled internal jugular venous catheters for hemodialysis: Safety and utility in modern day world

    Directory of Open Access Journals (Sweden)

    Manish Rathi

    2016-08-01

    Full Text Available Background: Absolute necessity in acute kidney injury (AKI and ignorance in chronic kidney disease (CKD make the use of un-cuffed, non-tunneled catheters an indispensable vascular access for hemodialysis. Although these catheters should be inserted under radiological guidance, it may not be feasible in certain circumstances. The aim of the present study was to evaluate safety and outcome of non-imaging assisted insertion of these catheters in internal jugular vein (IJV for hemodialysis. Methods: We analyzed 233 attempts of non-imaging assisted un-cuffed, non-tunneled IJV catheterization at our center. The immediate insertion complications, duration of use, rate and type of infection and other complications were assessed. Results: Out of the 233 attempts, 223 (213-right, 10-left were successful. The most common indication was AKI (n = 127, 54.5%, followed by CKD (n = 99, 42.5%. Successful catheterization at first attempt was achieved in 78.9%. Insertion complications were noted in 12.8% and included arterial puncture (5.2%, hematoma (3.0% and malposition (2.1%. Amongst 219 catheters followed for 4825 days, the mean duration of use was 22 days. Catheter related infections occurred in 42 patients with an incidence of 8.7 per 1000 catheter days. Bacteraemia was present in 10/36 cases (27.7%, positive catheter tip cultures in 71.4% cases and staphylococcal species were the most common organism. Cumulative hazard analysis by Cox regression revealed a linear increase in the risk for infection with each week. Conclusion: Non-imaging assisted insertion of uncuffed, non-tunneled catheters is associated with slightly higher rate of insertion complication but comparable outcome in terms of infection rate or days of use. Keywords: Hemodialysis, Internal jugular vein catheterization, Catheter related infection

  18. Skin graft

    Science.gov (United States)

    Skin transplant; Skin autografting; FTSG; STSG; Split thickness skin graft; Full thickness skin graft ... donor site. Most people who are having a skin graft have a split-thickness skin graft. This takes ...

  19. Experimental insertions

    International Nuclear Information System (INIS)

    Sandweiss, J.; Kycia, T.F.

    1975-01-01

    A discussion is given of the eight identical experimental insertions for the planned ISABELLE storage rings. Four sets of quadrupole doublets are used to match the β functions in the insertions to the values in the cells, and the total free space available at the crossing point is 40 meters. An asymmetric beam energy operation is planned, which will be useful in a number of experiments

  20. The use of modern dressings in managing split-thickness skin graft donor sites: a single-centre randomised controlled trial.

    Science.gov (United States)

    Kazanavičius, M; Cepas, A; Kolaityte, V; Simoliuniene, R; Rimdeika, R

    2017-06-02

    To identify the most appropriate, most suitable and most efficient dressing for split-thickness skin graft (STSG) donor sites. Comparing the wound healing rate, pain severity and duration, as well as the dressing change frequency in four randomised patient groups. A single-centre non-blinded randomised controlled trial was carried out during 2010-2014. All patients treated for skin defects/lesions (due to burns, trauma or ulcers) using STSG were included in the study. All patients were randomly allocated in four different donor site treatment groups; polyurethane (PU group, Mepilex); polyurethane with silicone membrane (PUSM group; Mepilex border,); transparent, breathable film (TBF group; Mepitel film) and cotton gauze dressings (CG group) using Excel 2007. We evaluated: wound healing time, pain severity and duration, the frequency of dressing change, donor site re-epithelialisation, donor site complications (signs of inflammation or infection). Patients were assessed on postoperative days: 1, 3, 6, 9, 12, 15, 18 and 21. After random allocation of study participants the number of patients in each group were: PU group n=25; PUSM group n=24; TBF group n=24; CG group n=25. The groups were homogenous according to gender, age, main pathology, donor site area and wound size. The STSG donor site healing time varied from 9 to 21 days. The mean healing time in the CG group was 14.76 days, whereas in the PU, PUSM, and TBF group it was significantly shorter; 12.25 days, 11.63 days and 10 days, respectively. Patients in the TBF group demonstrated the most rapid healing time with 66.7% of STSG donor sites healed by postoperative day 9. The pain duration interval in modern dressing groups (PU, PUSM and TBF groups) was 0-9 days, whereas it was 6-18 day in the CS group. Pain intensity mean on postoperative day 1 was 2.21 in the PU group; 1.67 in the PUSM group; 1.46 in the TBF group and 3.04 in the CG group. The average pain duration in Group PU, PUSM, and TBF was 4.08 days; 2

  1. Advances in radiation grafting

    International Nuclear Information System (INIS)

    Hegazy, El-Sayed A.; AbdEl-Rehim, H.A.; Kamal, H.; Kandeel, K.A.

    2001-01-01

    Graft copolymerization is an attractive means for modifying base polymers because grafting frequently results in the superposition of properties relating to the backbone and pendent chains. Among the various methods for initiating the grafting reaction, ionizing radiation is the cleanest and most versatile method of grafting available. Ion-exchange membranes play an important role in modern technology, especially in separation and purification of materials. The search for improved membrane composition has considered almost every available polymeric material because of its great practical importance. Grafting of polymers with a mixture of monomers is important since different types of chains containing different functional groups are included. A great deal is focused on the waste treatment of heavy and toxic metals from wastewater because of the severe problems of environmental pollution. Functionalized polymers suitable for metal adsorption with their reactive functional groups such as carboxylic and pyridine groups suitable for waste treatment were prepared by radiation grafting method. More reactive chelating groups were further introduced to the grafted copolymer through its functional groups by chemical treatments with suitable reagents. The advances of radiation grafting and possible uses are briefly discussed

  2. Postoperative radiographic evaluation of vascularized fibular grafts

    International Nuclear Information System (INIS)

    Manaster, B.J.; Coleman, D.A.; Bell, D.A.

    1989-01-01

    This paper reports on thirty-five patients with free vascularized fibular grafts examined postoperatively with plain radiography. Early graft incorporation is seen as a fuzziness of the cortex at the site of its insertion into the host bone. Causes of failure in grafting for bone defects include graft fracture, hardware failure, and infection. A high percentage of complications or at least delayed unions occurred when vascularized fibular grafts were used to fill defects in the lower extremity. Conversely, upper extremity defects bridged by vascularized grafts heal quickly and hypertrophy. Vascularized grafts placed in the femoral head and neck for a vascular necrosis incorporate early on their superior aspect. The osseous tunnel in which they are placed is normally wider than the graft and often becomes sclerotic; this appearance does not represent nonunion

  3. Skin Graft

    OpenAIRE

    Shimizu, Ruka; Kishi, Kazuo

    2012-01-01

    Skin graft is one of the most indispensable techniques in plastic surgery and dermatology. Skin grafts are used in a variety of clinical situations, such as traumatic wounds, defects after oncologic resection, burn reconstruction, scar contracture release, congenital skin deficiencies, hair restoration, vitiligo, and nipple-areola reconstruction. Skin grafts are generally avoided in the management of more complex wounds. Conditions with deep spaces and exposed bones normally require the use o...

  4. Evolution of skin grafting for treatment of burns: Reverdin pinch grafting to Tanner mesh grafting and beyond.

    Science.gov (United States)

    Singh, Mansher; Nuutila, Kristo; Collins, K C; Huang, Anne

    2017-09-01

    Skin grafting is the current standard care in the treatment of full thickness burns. It was first described around 1500 BC but the vast majority of advancements have been achieved over the past 200 years. An extensive literature review was conducted on Pubmed, Medline and Google Scholar researching the evolution of skin grafting techniques. The authors concentrated on the major landmarks of skin grafting and also provide an overview of ongoing research efforts in this field. The major innovations of skin grafting include Reverdin pinch grafting, Ollier grafting, Thiersch grafting, Wolfe grafting, Padgett dermatome and modifications, Meek-wall microdermatome and Tanner mesh grafting. A brief description of the usage, advantages and limitations of each technique is included in the manuscript. Skin grafting technique have evolved significantly over past 200 years from Reverdin pinch grafting to modern day meshed skin grafts using powered dermatome. Increasing the expansion ratio and improving the cosmetic and functional outcome are the main focus of ongoing skin grafting research and emerging techniques (such as Integra ® , Recell ® , Xpansion ® ) are showing promise. Copyright © 2017 Elsevier Ltd and ISBI. All rights reserved.

  5. Pancreas grafts

    International Nuclear Information System (INIS)

    Hahn, D.; Buell, U.; Land, W.; Unertl, K.

    1981-01-01

    Perfusion studies with sup(99m)Tc-DTPA, which has hitherto been used routinely to investigate renal grafts, have also proved useful for monitoring the perfusion of pancreas grafts. A total perfusion failure is equally reliably demonstrable as in renal grafts. Quantitatively smaller perfusion alterations can be demonstrated by monitoring the course. It seems possible to differentiate the salivary edema of a rejection reaction, well known from animal experiments, with the help of other paramters (e.g. creatinine). Further clinical studies are however necessary to confirm these results. (orig.) [de

  6. Lattice insertions for POPAE

    International Nuclear Information System (INIS)

    Cho, Y.; Crosbie, E.A.; Diebold, R.; Johnson, D.E.; Ohnuma, S.; Ruggiero, A.G.; Teng, L.C.

    1977-01-01

    Four types of insertions are described for the six 200-m straight sections of POPAE. All have dispersion matched to zero. (1) Injection-ejection insertion--This has proper high-β values and phase advances for horizontal injection and vertical ejection. (2) Phase-adjust insertion--The phase advance in this insertion is adjustable over a range of approximately 100 0 . (3) General-purpose insertion--The β* is adjustable from 2.5. to 200 m and the crossing angle is adjustable from 0 to 11 mrad. (4) High-luminosity insertion--This gives an even lower β + of meter

  7. Feeding tube insertion - gastrostomy

    Science.gov (United States)

    ... this page: //medlineplus.gov/ency/article/002937.htm Feeding tube insertion - gastrostomy To use the sharing features on this page, please enable JavaScript. A gastrostomy feeding tube insertion is the placement of a feeding ...

  8. Chest tube insertion

    Science.gov (United States)

    Chest drainage tube insertion; Insertion of tube into chest; Tube thoracostomy; Pericardial drain ... Be careful there are no kinks in your tube. The drainage system should always sit upright and be placed ...

  9. Clinical outcome of narrow diameter implants inserted into allografts

    Directory of Open Access Journals (Sweden)

    Maurizio Franco

    2009-08-01

    Full Text Available OBJECTIVE: Narrow diameter implants (NDI (i.e. diameter <3.75 mm are a potential solution for specific clinical situations, such as reduced interradicular bone, thin alveolar crest and replacement of teeth with small cervical diameter. NDI have been available in clinical practice since the 1990s, but only few studies have analyzed their clinical outcome and no study have investigated NDI inserted in fresh-frozen bone (FFB grafts. Thus, a retrospective study on a series of NDI placed in homologue FFB was designed to evaluate their clinical outcome. MATERIAL AND METHODS: In the period between December 2003 and December 2006, 36 patients (22 females and 14 males, mean age 53 years with FFB grafts were selected and 94 different NDI were inserted. The mean follow-up was 25 months. To evaluate the effect of several host-, surgery-, and implant-related factors, marginal bone loss (MBL was considered an indicator of success rate (SCR. The Kaplan Meier algorithm and Cox regression were used. RESULTS: Only 5 out of 94 implants were lost (i.e. survival rate - SVR 95.7% and no differences were detected among the studied variables. On the contrary, the Cox regression showed that the graft site (i.e. maxilla reduced MBL. CONCLUSIONS: NDI inserted in FFB have a high SVR and SCR similar to those reported in previous studies on regular and NDI inserted in non-grafted jaws. Homologue FFB is a valuable material in the insertion of NDI.

  10. Stent graft placement for dysfunctional arteriovenous grafts

    Energy Technology Data Exchange (ETDEWEB)

    Jeon, Gyeong Sik [Dept. of Radiology, CHA Bundang Medical Center, College of Medicine, CHA University, Seongnam (Korea, Republic of); Shin, Byung Seok; Ohm, Joon Young; Ahn, Moon Sang [Chungnam National University Hospital, Daejeon (Korea, Republic of)

    2015-07-15

    This study aimed to evaluate the usefulness and outcomes of stent graft use in dysfunctional arteriovenous grafts. Eleven patients who underwent stent graft placement for a dysfunctional hemodialysis graft were included in this retrospective study. Expanded polytetrafluoroethylene covered stent grafts were placed at the venous anastomosis site in case of pseudoaneurysm, venous laceration, elastic recoil or residual restenosis despite the repeated angioplasty. The patency of the arteriovenous graft was evaluated using Kaplan-Meier analysis. Primary and secondary mean patency was 363 days and 741 days. Primary patency at 3, 6, and 12 months was 82%, 73%, and 32%, respectively. Secondary patency at the 3, 6, 12, 24, and 36 months was improved to 91%, 82%, 82%, 50%, and 25%, respectively. Fractures of the stent graft were observed in 2 patients, but had no effect on the patency. Stent graft placement in dysfunctional arteriovenous graft is useful and effective in prolonging graft patency.

  11. Modern programming language

    Science.gov (United States)

    Feldman, G. H.; Johnson, J. A.

    1980-01-01

    Structural-programming language is especially-tailored for producing assembly language programs for MODCOMP II and IV mini-computes. Modern programming language consists of set of simple and powerful control structures that include sequencing alternative selection, looping, sub-module linking, comment insertion, statement continuation, and compilation termination capabilities.

  12. Intravascular stent graft with polyurethane and metallic stent: experimental study

    International Nuclear Information System (INIS)

    Do, Young Soo; Lee, Won Jae; Kim, Boo Kyung Han; Park, Jae Hyung; Lee, Hak Jong; Lee, Sang Hyun; Kim, Sung Hyun; Kim, Jong Won; Ha, Jongwon

    1997-01-01

    To evaluate the usefulness of a new model of the stent graft, and of tissue response related to placement of the stent graft. The stent graft was constructed from polyurethane (Pellethane) graft and Hanaro stent(12mm in diameter, 45mm in length, 10 bends). A stent grafts was inserted into the lower thoracic aorta in each of six adult mongrel dogs(body weight, 12-16kg). At one, two, four, and six months, follow-up studies of angiography and spiral CT angiography were preformed to evaluate wascular patency, vascular stenosis, and thrombus formation. Two dogs were sacrificed at 1month, 2months, and 6months after insertion of the stent graft and macroscopic, light microscopic, and scanning electron microscopic examinations of the aortic segment including the stent graft were performed to evaluate intimal hyperplasia, endothelial growth to the graft, and thrombus formation. During follow-up at one, two, four, and six months, angiography or spiral CT angiography showed 20-100% luminal stenosis or occlusion of the lower thoracic aorta by the thrombus and perigraft leaks in three dogs(50%), and collateral vessels caused by occlusion of the aorta in two (33.3%). On gross examination, there were thrombi of 1-5mm thickness at the graft portions in all dogs, and this thickness gradually increased. The mean thickness of intimal hyperplasia at the stent portion gradually increased from 120μm to 227μm and the mean thickness of intimal hyperplasia at the graft portion from 93μm to 914μm. This thickness was greater at the graft portion than at the stent portion. Scanning electron microscopy showed elliptical endothelial lining on the neointimal surfaces at each end of the graft. Thrombi caused stenosis or occlusion of the stent graft. In order for such a graft to be ideal, further study is needed

  13. Bone Graft Alternatives

    Science.gov (United States)

    ... Spine Treatment Spondylolisthesis BLOG FIND A SPECIALIST Treatments Bone Graft Alternatives Patient Education Committee Patient Education Committee ... procedure such as spinal fusion. What Types of Bone Grafts are There? Bone grafts that are transplanted ...

  14. Insertion Modeling and Its Applications

    OpenAIRE

    Alexander Letichevsky; Oleksandr Letychevskyi; Vladimir Peschanenko

    2016-01-01

    The paper relates to the theoretical and practical aspects of insertion modeling. Insertion modeling is a theory of agents and environments interaction where an environment is considered as agent with a special insertion function. The main notions of insertion modeling are presented. Insertion Modeling System is described as a tool for development of different kinds of insertion machines. The research and industrial applications of Insertion Modeling System are presented.

  15. Percutaneous Ureteral stent insertion

    Energy Technology Data Exchange (ETDEWEB)

    Yoon, Yup; Sung, Dong Wook; Choi, Woo Suk; Lee, Dong Ho; Ko, Young Tae; Lee, Sun Wha; Lim, Jae Hoon [Kyung Hee University Hospital, Seoul (Korea, Republic of)

    1990-10-15

    Percutaneous ureteral stent insertion is a treatment of permanent or temporary urinary diversion to maintain continuity and function of the obstructed and injured ureter. We performed 31 cases of percutaneous double pig tall ureteral stent insertion in 21 patients, included 13 patients with malignant ureteral obstruction and eight patients with injured ureter as well as benign inflammatory stricture. Satisfactory resulted was obtained in all patients but one, who need percutaneous nephrostomy on week later for urinary diversion. No significant complication was encountered. The authors concluded that percutaneous ureteral stent insertion, an interventional procedure alternative to urologic retrograde method, is an effective method for urinary diversion.

  16. Variation in the insertion of the palmaris longus tendon

    Science.gov (United States)

    Sunil, Vinutha; Rajanna, Shubha; Gitanjali; Kadaba, Jayanthi

    2015-01-01

    The palmaris longus is harvested as a tendon graft in various surgical procedures. We herein report the variations in the insertion of the palmaris longus tendon. During a routine dissection, a rare variation in the insertion of the palmaris longus tendon was observed. In the left forearm, the palmaris longus tendon bifurcated, while in the right forearm, the palmaris longus tendon trifurcated, giving rise to an accessory muscle, which passed superficial to the ulnar artery and ulnar nerve. The accessory muscle was supplied by a deep branch of the ulnar nerve, and the ulnar artery was observed to be tortuous. During reconstructive surgeries, surgeons should bear in mind the accessory muscle. Also, since the palmaris longus muscle provides a very useful graft in tendon surgery, every surgeon should be aware of the variations in the insertion of the palmaris longus tendon. PMID:25640108

  17. Modernity after Modernity

    Directory of Open Access Journals (Sweden)

    Marin Dinu

    2007-08-01

    Full Text Available A strategy for the second modernization raises, beyond objectives, a series of epistemicresponsibilities. It is known that modernization stemming from the Enlightment had, among other things,the pretense that it is a project which is self-legitimating. Its profound rationales are the only justification.Referential self-centering proved to be the one that made possible a practice of the new. Modernizationhaving the function of renouncing myth – meaning an eliminatory formula for the past – and thefixation in the opportunity and potentiality of the present, seemed to close an insoluble but extremelyengrossing problem: that of a propensity towards utopia, of the risky escape towards the future. Thetraditionalization of the new constitutes a support for the daring to break out of the captivity of themoment.Modernization becomes the experience of combining the new which, thus, creates a succession ofpresent times. The future is no longer the result of fantasy, but a system’s direct expression to combine thenew. Therefore the future is an option for one or another model of the present, often tested previouslysomewhere else. In a non-metaphysical way, the future can be seen, touched, tried, lived by simplegeographical movement. The sense of evolution has de-temporalized taking the form of the concomitant,parallel, enclosed, neighboring space. We just have to be in the trend, to evolve in the context.Globalization defines the context and its conception – as a project of the second modernity – showsus the trends. The problem is how to understand the context in order to find the sense of the trend. Are wethe load the sense with the values of the first modernity or will we have to turn to the values of anothermodernity? Why do we have to move away from the significance of the processes which made up the firstmodernity? How do we relate to the content of the new context in which the structural trends of today’sworld are taking place? What is the

  18. Modern teaching for modern education

    OpenAIRE

    Mirascieva, Snezana

    2016-01-01

    Carrying the epithet of being contemporary education today means modern teaching. If modern education is a state in the field of education of all its elements, then teaching will also be a state with its own special features defining it as modern. The main issues of concern in this paper relate to what constitutes modern teaching, which features determine it as being modern, and how much is teaching today following the trend of modernization.

  19. Bone grafting: An overview

    Directory of Open Access Journals (Sweden)

    D. O. Joshi

    2010-08-01

    Full Text Available Bone grafting is the process by which bone is transferred from a source (donor to site (recipient. Due to trauma from accidents by speedy vehicles, falling down from height or gunshot injury particularly in human being, acquired or developmental diseases like rickets, congenital defects like abnormal bone development, wearing out because of age and overuse; lead to bone loss and to replace the loss we need the bone grafting. Osteogenesis, osteoinduction, osteoconduction, mechanical supports are the four basic mechanisms of bone graft. Bone graft can be harvested from the iliac crest, proximal tibia, proximal humerus, proximal femur, ribs and sternum. An ideal bone graft material is biologically inert, source of osteogenic, act as a mechanical support, readily available, easily adaptable in terms of size, shape, length and replaced by the host bone. Except blood, bone is grafted with greater frequency. Bone graft indicated for variety of orthopedic abnormalities, comminuted fractures, delayed unions, non-unions, arthrodesis and osteomyelitis. Bone graft can be harvested from the iliac crest, proximal tibia, proximal humerus, proximal femur, ribs and sternum. By adopting different procedure of graft preservation its antigenicity can be minimized. The concept of bone banking for obtaining bone grafts and implants is very useful for clinical application. Absolute stability require for successful incorporation. Ideal bone graft must possess osteogenic, osteoinductive and osteocon-ductive properties. Cancellous bone graft is superior to cortical bone graft. Usually autologous cancellous bone graft are used as fresh grafts where as allografts are employed as an alloimplant. None of the available type of bone grafts possesses all these properties therefore, a single type of graft cannot be recomm-ended for all types of orthopedic abnormalities. Bone grafts and implants can be selected as per clinical problems, the equipments available and preference of

  20. ALS insertion devices

    International Nuclear Information System (INIS)

    Hoyer, E.; Chin, J.; Halbach, K.; Hassenzahl, W.V.; Humphries, D.; Kincaid, B.; Lancaster, H.; Plate, D.

    1990-11-01

    The Advanced Light Source (ALS), the first US third generation synchrotron radiation source, is currently under construction at the Lawrence Berkeley Laboratory. The low-emittance, 1.5 GeV electron storage ring and the insertion devices are specifically designed to produce high brightness beams in the UV to soft X-Ray range. The planned initial complement of insertion devices includes four 4.6 m long undulators, with period lengths of 3.9 cm, 5.0 cm (2) and 8.0 cm, and a 2.9 m long wiggler of 16 cm period length. Undulator design is well advanced and fabrication has begun on the 5.0 cm and 8.0 cm period length undulators. This paper discusses ALS insertion device requirements; general design philosophy; and design of the magnetic structure, support structure/drive systems, control system and vacuum system. 18 refs., 9 figs., 5 tabs

  1. Reactivity insertion accident analysis

    International Nuclear Information System (INIS)

    Moreira, J.M.L.; Nakata, H.; Yorihaz, H.

    1990-04-01

    The correct prediction of postulated accidents is the fundamental requirement for the reactor licensing procedures. Accident sequences and severity of their consequences depend upon the analysis which rely on analytical tools which must be validated against known experimental results. Present work presents a systematic approach to analyse and estimate the reactivity insertion accident sequences. The methodology is based on the CINETHICA code which solves the point-kinetics/thermohydraulic coupled equations with weighted temperature feedback. Comparison against SPERT experimental results shows good agreement for the step insertion accidents. (author) [pt

  2. ISABELLE insertion quadrupoles

    International Nuclear Information System (INIS)

    Kaugerts, J.; Polk, I.; Sampson, W.; Dahl, P.F.

    1979-01-01

    Beam focussing and control at the beam intersection regions of ISABELLE is accomplished by a number of superconducting insertion quadrupoles. These magnets differ from the standard ISABELLE quadrupoles in various ways. In particular, the requirements of limited space near the intersections and aperture for beam extraction impose constraints on their configuration. To achieve optimum beam focussing and provide tuning flexibility calls for stronger quadrupole trim windings than those in the standard quadrupoles. The magnetic and mechanical design of the insertion quadrupoles and their associated correction and steering windings to accomplish the above tasks is presented

  3. Method of inserting fuel rod

    International Nuclear Information System (INIS)

    Kamimoto, Shuji; Imoo, Makoto; Tsuchida, Kenji.

    1991-01-01

    The present invention concerns a method of inserting a fuel rod upon automatic assembling, automatic dismantling and reassembling of a fuel assembly in a light water moderated reactor, as well as a device and components used therefor. That is, a fuel rod is inserted reliably to an aimed point of insertion by surrounding the periphery of the fuel rod to be inserted with guide rods, and thereby suppressing the movement of the fuel rod during insertion. Alternatively, a fuel rod is inserted reliably to a point of insertion by inserting guide rods at the periphery of the point of insertion for the fuel rod to be inserted thereby surrounding the point of insertion with the guide rods or fuel rods. By utilizing fuel rods already present in the fuel assembly as the guide rods described above, the fuel rod can be inserted reliably to the point of insertion with no additional devices. Dummy fuel rods are previously inserted in a fuel assembly which are then utilized as the above-mentioned guide rods to accurately insert the fuel rod to the point of insertion. (I.S.)

  4. Insertion in Persian

    Science.gov (United States)

    Kambuziya, Aliyeh Kord-e Zafaranlu; Dehghan, Masoud

    2011-01-01

    This paper investigates epenthesis process in Persian to catch some results in relating to vowel and consonant insertion in Persian lexicon. This survey has a close relationship to the description of epenthetic consonants and the conditions in which these consonants are used. Since no word in Persian may begin with a vowel, so that hiatus can't be…

  5. The Composite Insertion Electrode

    DEFF Research Database (Denmark)

    Atlung, Sven; Zachau-Christiansen, Birgit; West, Keld

    1984-01-01

    The specific energy obtainable by discharge of porous insertion electrodes is limited by electrolyte depletion in thepores. This can be overcome using a solid ion conductor as electrolyte. The term "composite" is used to distinguishthese electrodes from porous electrodes with liquid electrolyte...

  6. Grafting and curing

    International Nuclear Information System (INIS)

    Garnett, J.L.; Loo-Teck Ng; Visay Viengkhou

    1998-01-01

    Progress in radiation grafting and curing is briefly reviewed. The two processes are shown to be mechanistically related. The parameters influencing yields are examined particularly for grafting. For ionising radiation grafting systems (EB and gamma ray) these include solvents, substrate and monomer structure, dose and dose-rate, temperature and more recently role of additives. In addition, for UV grafting, the significance of photoinitiators is discussed. Current applications of radiation grafting and curing are outlined. The recent development of photoinitiator free grafting and curing is examined as well as the potential for the new excimer laser sources. The future application of both grafting and curing is considered, especially the significance of the occurrence of concurrent grafting during cure and its relevance in environmental considerations

  7. Skin graft - slideshow

    Science.gov (United States)

    ... this page: //medlineplus.gov/ency/presentations/100100.htm Skin graft - series—Normal anatomy To use the sharing features ... entire body, and acts as a protective barrier. Skin grafts may be recommended for: Extensive wounds Burns Specific ...

  8. Bone grafts in dentistry

    Directory of Open Access Journals (Sweden)

    Prasanna Kumar

    2013-01-01

    Full Text Available Bone grafts are used as a filler and scaffold to facilitate bone formation and promote wound healing. These grafts are bioresorbable and have no antigen-antibody reaction. These bone grafts act as a mineral reservoir which induces new bone formation.

  9. Fuel insert shuffler

    International Nuclear Information System (INIS)

    Naser, J.; Colley, R.; Gaiser, J.; Brookmire, T.; Engle, S.

    1987-01-01

    The potential for the use of expert systems in the nuclear power industry is widely recognized. The benefits of such systems include consistency of reasoning during off-normal situations when humans are under great stress, the reduction of time required to perform certain functions and the retention of human expertise in performing specialized functions. As the potential benefits are more and more demonstrated and realized, the development of expert systems becomes a necessary part of the nuclear power industry. The development of the fuel insert shuffle expert system is used as a case study. In fact, it shows that the potential benefits are realizable. Currently, the development of the insert shuffle plan requires three to four man-weeks of effort. Further modifications to this plan are sometimes required dur to either changes in the desired core load pattern or damaged fuel assemblies or inserts. These changes generally require two to four man-days of effort and could be stressful if they are critical path items on the outage schedule

  10. Electronics Modernization

    Data.gov (United States)

    National Aeronautics and Space Administration — There is a need to reduce mass and volume on any spacecraft whether for earth orbit insertion or travel within the solar system. Less mass and a smaller volume can...

  11. Fuel assembly insertion system

    International Nuclear Information System (INIS)

    Barkhurst, D.J.

    1987-01-01

    This patent describes a nuclear reactor facility having fuel bundles: a system for the insertion of a fuel bundle into a position where vertically arranged fuel bundles surround and are adjacent the system comprising, in combination, separate and individual centering devices secured to and disposed on top of each fuel bundle adjacent the position. Each such centering device has a generally box-like cap configuration on the upper end of each fuel bundle and includes: a top wall; first and second side walls, each secured along and upper edge to the top wall; a rear plate attached along opposite vertical edges to the first and second side walls; a front inclined wall joined along an upper edge to the top to the wall and attached along opposite vertical edges first and second side walls; pad means secured to the lower edge of the first and second side walls, the front inclined wall and the rear plate for mounting each centering device on top of an associated fuel bundle; pin means carried by at least two of the pad means engageable with an associated aperature for locating and laterally fixing each centering device on top of its respective fuel bundle. Each front inclined wall of each of the centering devices is orientated on top of its respective fuel bundle to slope upwardly and away from the position where upon downward insertion of a fuel bundle any contact between the lower end of the fuel bundle inserted with a front inclined wall of a centering device will laterally deflect the fuel bundle. Each centering device further includes a central socket means secured to the top wall, and an elongated handling pole pivotally attached to the socket

  12. Symplectic models for general insertion devices

    International Nuclear Information System (INIS)

    Wu, Y.; Forest, E.; Robin, D. S.; Nishimura, H.; Wolski, A.; Litvinenko, V. N.

    2001-01-01

    A variety of insertion devices (IDs), wigglers and undulators, linearly or elliptically polarized,are widely used as high brightness radiation sources at the modern light source rings. Long and high-field wigglers have also been proposed as the main source of radiation damping at next generation damping rings. As a result, it becomes increasingly important to understand the impact of IDs on the charged particle dynamics in the storage ring. In this paper, we report our recent development of a general explicit symplectic model for IDs with the paraxial ray approximation. High-order explicit symplectic integrators are developed to study real-world insertion devices with a number of wiggler harmonics and arbitrary polarizations

  13. Data Insertion in Bitcoin's Blockchain

    Directory of Open Access Journals (Sweden)

    Andrew Sward

    2018-04-01

    Full Text Available This paper provides the first comprehensive survey of methods for inserting arbitrary data into Bitcoin’s blockchain. Historical methods of data insertion are described, along with lesser-known techniques that are optimized for efficiency. Insertion methods are compared on the basis of efficiency, cost, convenience of data reconstruction, permanence, and potentially negative impact on the Bitcoin ecosystem.

  14. Modernity: Are Modern Times Different?

    Directory of Open Access Journals (Sweden)

    Lynn Hunt

    2014-12-01

    Full Text Available “Modernity” has recently been the subject of considerable discussion among historians. This article reviews some of the debates and argues that modernity is a problematic concept because it implies a complete rupture with “traditional” ways of life. Studies of key terms are undertaken with the aid of Google Ngrams. These show that “modernity,” “modern times,” and “traditional” —in English and other languages— have a history of their own. A brief analysis of the shift from a self oriented toward equilibrium to a self oriented toward stimulation demonstrates that modernity is not necessary to historical analysis.

  15. Dilatation of aortic grafts over time: what to expect and when to be concerned

    DEFF Research Database (Denmark)

    Schroeder, Torben V; Eldrup, Nikolaj; Just, Sven

    2009-01-01

    Dilatation of aortic prosthetic grafts is commonly reported, but most reports are anecdotal, with little objective data in the literature. We performed a prospective trial of 303 patients who underwent prosthetic graft repair for aortic aneurysm or occlusive disease, randomizing patients between...... insertion of a woven polyester or expanded polytetrafluoroethylene (ePTFE) graft. Patients were followed with computed tomography and ultrasonography for up to 5 years in order to assess the frequency and magnitude of postoperative dilatation. Graft dilatation was documented in patients with polyester...... grafts at 12 months. Thereafter and up to 60 months, polyester grafts did not dilate further. After 5 years, polyester prostheses had dilated by 25% and ePTFE by 12.5%, as determined by computed tomography imaging. These observations suggest that dilatation of prosthetic grafts is more frequent...

  16. Osseous scintigraphy and auxiliary graft

    International Nuclear Information System (INIS)

    Khelifa, F.; Siles, S.; Puech, B.

    1992-01-01

    The scintigraphy could be a good way to survey the osseous graft: three cases are studied in which were recognized the presence of a graft, surinfection, graft lysis, pseudo-arthrosis, algodystrophy. 8 refs., 5 figs

  17. Meniscal allograft transplantation. Part 1: systematic review of graft biology, graft shrinkage, graft extrusion, graft sizing, and graft fixation.

    Science.gov (United States)

    Samitier, Gonzalo; Alentorn-Geli, Eduard; Taylor, Dean C; Rill, Brian; Lock, Terrence; Moutzouros, Vasilius; Kolowich, Patricia

    2015-01-01

    To provide a systematic review of the literature regarding five topics in meniscal allograft transplantation: graft biology, shrinkage, extrusion, sizing, and fixation. A systematic literature search was conducted using the PubMed (MEDLINE), ScienceDirect, and EBSCO-CINAHL databases. Articles were classified only in one topic, but information contained could be reported into other topics. Information was classified according to type of study (animal, in vitro human, and in vivo human) and level of evidence (for in vivo human studies). Sixty-two studies were finally included: 30 biology, 3 graft shrinkage, 11 graft extrusion, 17 graft size, and 6 graft fixation (some studies were categorized in more than one topic). These studies corresponded to 22 animal studies, 22 in vitro human studies, and 23 in vivo human studies (7 level II, 10 level III, and 6 level IV). The principal conclusions were as follows: (a) Donor cells decrease after MAT and grafts are repopulated with host cells form synovium; (b) graft preservation alters collagen network (deep freezing) and causes cell apoptosis with loss of viable cells (cryopreservation); (c) graft shrinkage occurs mainly in lyophilized and gamma-irradiated grafts (less with cryopreservation); (d) graft extrusion is common but has no clinical/functional implications; (e) overall, MRI is not superior to plain radiograph for graft sizing; (f) graft width size matching is more important than length size matching; (g) height appears to be the most important factor influencing meniscal size; (h) bone fixation better restores contact mechanics than suture fixation, but there are no differences for pullout strength or functional results; and (i) suture fixation has more risk of graft extrusion compared to bone fixation. Systematic review of level II-IV studies, Level IV.

  18. Facility target insert shielding assessment

    Energy Technology Data Exchange (ETDEWEB)

    Mocko, Michal [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2015-10-06

    Main objective of this report is to assess the basic shielding requirements for the vertical target insert and retrieval port. We used the baseline design for the vertical target insert in our calculations. The insert sits in the 12”-diameter cylindrical shaft extending from the service alley in the top floor of the facility all the way down to the target location. The target retrieval mechanism is a long rod with the target assembly attached and running the entire length of the vertical shaft. The insert also houses the helium cooling supply and return lines each with 2” diameter. In the present study we focused on calculating the neutron and photon dose rate fields on top of the target insert/retrieval mechanism in the service alley. Additionally, we studied a few prototypical configurations of the shielding layers in the vertical insert as well as on the top.

  19. Bone graft revascularization strategies

    NARCIS (Netherlands)

    Willems, W.F.

    2014-01-01

    Reconstruction of avascular necrotic bone by pedicled bone grafting is a well-known treatment with little basic research supporting its application. A new canine model was used to simulate carpal bone avascular necrosis. Pedicled bone grafting proved to increase bone remodeling and bone blood flow,

  20. Modern cosmology

    International Nuclear Information System (INIS)

    Zeldovich, Y.B.

    1983-01-01

    This paper fives a general review of modern cosmology. The following subjects are discussed: hot big bang and periodization of the evolution; Hubble expansion; the structure of the universe (pancake theory); baryon asymmetry; inflatory universe. (Auth.)

  1. Insertion device and method for accurate and repeatable target insertion

    Science.gov (United States)

    Gubeli, III, Joseph F.; Shinn, Michelle D.; Bevins, Michael E.; Dillon-Townes, Lawrence; Neil, George R.

    2017-07-04

    The present invention discloses a device and a method for inserting and positioning a target within a free electron laser, particle accelerator, or other such device that generates or utilizes a beam of energy or particles. The system includes a three-point registration mechanism that insures angular and translational accuracy and repeatability of positioning upon multiple insertions within the same structure.

  2. Satisfactory surgical option for cartilage graft absorption in microtia reconstruction.

    Science.gov (United States)

    Han, So-Eun; Oh, Kap Sung

    2016-04-01

    We routinely perform auricular elevation at least 6 months after implantation of framework in microtia reconstruction using costal cartilage. However, in a few cases, cartilage graft absorption has occurred, which has led to contour irregularity with unfavorable long-term results. In the present study, we recount the details of using additional rib cartilage augmentation to achieve an accentuated contour in cartilage graft absorption cases. The cartilage graft absorption was defined as contour irregularity or cartilage graft deformation as evaluated by the surgeon and patient. Depending on the extent of cartilage graft absorption, another rib cartilage framework was added to the previously implanted framework, targeting the absorption area. We used banked cartilage or harvested new cartilage based on three-dimensional rib computed tomography. Additional recontouring of framework was conducted in eight patients who were examined for cartilage graft absorption from 1.5 to 5 years after implantation of the framework. Four patients received additional rib cartilage augmentation and tissue expander insertion simultaneously prior to auricular elevation. Two patients underwent auricular elevation simultaneously. In another two patients, additional rib cartilage augmentation was performed before auricular elevation. The mean follow-up period was 18 months, and in all cases reconstructive results were acceptable. Although further follow-up evaluation is required, additional rib cartilage augmentation is an attractive surgical option for cartilage graft absorption cases. Copyright © 2016 European Association for Cranio-Maxillo-Facial Surgery. Published by Elsevier Ltd. All rights reserved.

  3. Lithium insertion in nanostructured titanates

    NARCIS (Netherlands)

    Borghols, W.J.H.

    2010-01-01

    Upon nano-sizing of insertion compounds several significant changes in Li-insertion behavior have been observed for sizes below approximately 50 nm. Although the origins of the phenomena are interrelated, the changes can be divided in three main observations. (1) The formation of new phases, leading

  4. Chest tube insertion - series (image)

    Science.gov (United States)

    Chest tubes are inserted to drain blood, fluid, or air and allow full expansion of the lungs. The tube is placed in the pleural space. The area where the tube will be inserted is numbed (local anesthesia). The patient may also be sedated. The chest ...

  5. Italian Modernities

    DEFF Research Database (Denmark)

    Thomassen, Bjørn; Forlenza, Rosario

    assumptions that have substituted for thought and that have perpetuated prejudices both within and outside Italy’s borders. Grounded in meticulous historical and ethnological research, Italian Modernities deserves as wide an audience as its scholarship is deep.” (Michael Herzfeld, Ernest E. Monrad Professor...

  6. Montreal Modern

    DEFF Research Database (Denmark)

    Handberg, Kristian

    2015-01-01

    , and the space age modernism of the 1960s following the Expo 67 and Quebec’s Quiet Revolution. This is reflected in the city’s thriving retro culture through the study of two groups of retro shops. In circulating specific memories and objects in a specific context, retro is an important negotiation of the past...

  7. Modern Cosmology

    CERN Document Server

    Zhang Yuan Zhong

    2002-01-01

    This book is one of a series in the areas of high-energy physics, cosmology and gravitation published by the Institute of Physics. It includes courses given at a doctoral school on 'Relativistic Cosmology: Theory and Observation' held in Spring 2000 at the Centre for Scientific Culture 'Alessandro Volta', Italy, sponsored by SIGRAV-Societa Italiana di Relativita e Gravitazione (Italian Society of Relativity and Gravitation) and the University of Insubria. This book collects 15 review reports given by a number of outstanding scientists. They touch upon the main aspects of modern cosmology from observational matters to theoretical models, such as cosmological models, the early universe, dark matter and dark energy, modern observational cosmology, cosmic microwave background, gravitational lensing, and numerical simulations in cosmology. In particular, the introduction to the basics of cosmology includes the basic equations, covariant and tetrad descriptions, Friedmann models, observation and horizons, etc. The ...

  8. Modern bureaucracy

    OpenAIRE

    Toye, John

    2006-01-01

    Max Weber believed that bureaucracy could be understood by analysing its ideal-typical characteristics, and that these characteristics would become more pervasive as the modern age advanced. Weber’s horizontal account of bureaucracy can be criticised on various grounds, including its unrealistic notion of bureaucratic rationality. An alternative view is proposed, namely, that the development of state bureaucracies is driven by the trajectory of the highpower politics in which they are nested....

  9. Modern Biology

    OpenAIRE

    ALEKSIC, Branko

    2014-01-01

    The purpose of this course is to learn the philosophy, principles, and techniques of modern biology. The course is particularly designed for those who have not learned biology previously or whose major is other than biology, and who may think that they do not need to know any biology at all. The topics are covered in a rather general, overview manner, but certain level of diligence in grasping concepts and memorizing the terminology is expected.

  10. Modern maths

    CERN Multimedia

    Thom,R

    1974-01-01

    Le Prof. R. Thom expose ses vues sur l'enseignement des mathématiques modernes et des mathémathiques de toujours. Il est un grand mathématicien et était professeur à Strasbourg; maintenant il est professeur de hautes études scientifiques et était invité par le Prof. Piaget à Genève

  11. Graft-Sparing Strategy for Thoracic Prosthetic Graft Infection.

    Science.gov (United States)

    Uchino, Gaku; Yoshida, Takeshi; Kakii, Bunpachi; Furui, Masato

    2018-04-01

     Thoracic prosthetic graft infection is a rare but serious complication with no standard management. We reported our surgical experience on graft-sparing strategy for thoracic prosthetic graft infection.  This study included patients who underwent graft-sparing surgery for thoracic prosthetic graft infection at Matsubara Tokushukai Hospital in Japan from January 2000 to October 2017.  There were 17 patients included in the analyses, with a mean age at surgery of 71.0 ± 10.5 years; 11 were men. In-hospital mortality was observed in five patients (29.4%).  Graft-sparing surgery for thoracic prosthetic graft infection is an alternative option particularly for early graft infection after hemiarch replacement. Georg Thieme Verlag KG Stuttgart · New York.

  12. The first insertion devices at SSRL - some personal recollections

    Energy Technology Data Exchange (ETDEWEB)

    Winick, H. [Stanford Linear Accelerator Center, CA (United States)

    1995-02-01

    The author recounts his experiences with insertion devices at the Stanford Synchrotron Radiation Laboratory. His first experiences with wigglers occured at the Cambridge Electron Accelerator, and was carried over to SSRL with the proposal for a six pole electromagnetic wiggler. Most modern undulators, and many wigglers are now designed around permanent magnets, and the origin of this transition at SSRL was rather fortuitous and humorous. It reflects some of the personality characteristics of Klaus Halbach.

  13. Modern Cosmology

    Energy Technology Data Exchange (ETDEWEB)

    Zhang Yuanzhong

    2002-06-21

    This book is one of a series in the areas of high-energy physics, cosmology and gravitation published by the Institute of Physics. It includes courses given at a doctoral school on 'Relativistic Cosmology: Theory and Observation' held in Spring 2000 at the Centre for Scientific Culture 'Alessandro Volta', Italy, sponsored by SIGRAV-Societa Italiana di Relativita e Gravitazione (Italian Society of Relativity and Gravitation) and the University of Insubria. This book collects 15 review reports given by a number of outstanding scientists. They touch upon the main aspects of modern cosmology from observational matters to theoretical models, such as cosmological models, the early universe, dark matter and dark energy, modern observational cosmology, cosmic microwave background, gravitational lensing, and numerical simulations in cosmology. In particular, the introduction to the basics of cosmology includes the basic equations, covariant and tetrad descriptions, Friedmann models, observation and horizons, etc. The chapters on the early universe involve inflationary theories, particle physics in the early universe, and the creation of matter in the universe. The chapters on dark matter (DM) deal with experimental evidence of DM, neutrino oscillations, DM candidates in supersymmetry models and supergravity, structure formation in the universe, dark-matter search with innovative techniques, and dark energy (cosmological constant), etc. The chapters about structure in the universe consist of the basis for structure formation, quantifying large-scale structure, cosmic background fluctuation, galaxy space distribution, and the clustering of galaxies. In the field of modern observational cosmology, galaxy surveys and cluster surveys are given. The chapter on gravitational lensing describes the lens basics and models, galactic microlensing and galaxy clusters as lenses. The last chapter, 'Numerical simulations in cosmology', deals with spatial and

  14. Modern plasmonics

    CERN Document Server

    Maradudin, Alexei A; Barnes, William L

    2014-01-01

    Plasmonics is entering the curriculum of many universities, either as a stand alone subject, or as part of some course or courses. Nanotechnology institutes have been, and are being, established in universities, in which plasmonics is a significant topic of research. Modern Plasmonics book offers a comprehensive presentation of the properties of surface plasmon polaritons, in systems of different structures and various natures, e.g. active, nonlinear, graded, theoretical/computational and experimental techniques for studying them, and their use in a variety of applications. Contains materia

  15. Modern spectroscopy

    CERN Document Server

    Hollas, J Michael

    2013-01-01

    The latest edition of this highly acclaimed title introduces the reader to a wide range of spectroscopies, and includes both the background theory and applications to structure determination and chemical analysis.  It covers rotational, vibrational, electronic, photoelectron and Auger spectroscopy, as well as EXAFs and the theory of lasers and laser spectroscopy. A  revised and updated edition of a successful, clearly written book Includes the latest developments in modern laser techniques, such as cavity ring-down spectroscopy and femtosecond lasers Provides numerous worked examples, calculations and questions at the end of chapters.

  16. Arteriovenous shunt graft ulceration with sinus and graft epithelialization

    Directory of Open Access Journals (Sweden)

    Pooja Singhal

    2015-03-01

    Full Text Available Arteriovenous fistula and grafts are used as access sites for patients with chronic kidney disease and are prone for complications. Stent grafts are used to treat access site complications. We report a rare and unusual finding of epithelialization of the sinus tract and the lumen of a polytetrafluoroethylene graft, following ulceration of the overlying skin.

  17. LOFT voltage insertion calibaration program

    International Nuclear Information System (INIS)

    Tillitt, D.N.; Miyasaki, F.S.

    1975-08-01

    The Loss-of-Fluid Test (LOFT) Facility is an experimental facility built around a ''scaled'' version of a large pressurized water reactor (LPWR). Part of this facility is the Data Acquisition and Visual Display System (DAVDS) as defined by the LOFT System Design Document SDD 1.4.2C. The DAVDS has a 702 data channel recording capability of which 548 are recorded digitally. The DAVDS also contains a Voltage Insertion Calibration Subsystem used to inject precise and known voltage steps into the recording systems. The computer program that controls the Voltage Insertion Calibration Subsystem is presented. 7 references. (auth)

  18. Haemodynamics in axillobifemoral bypass grafts

    NARCIS (Netherlands)

    C.H. Wittens

    1992-01-01

    textabstractThis thesis is based on four publications on the subject of graft configuration and haemodynamics in axillobifemoral bypass grafts: 1. A clinical evaluation of 17 patients with axillobifemoral bypass graft operations, performed for various indications. Two important observations were

  19. Primary renal graft thrombosis

    NARCIS (Netherlands)

    Bakir, N; Sluiter, WJ; Ploeg, RJ; van Son, WJ; Tegzess, Adam

    Background. Renal allograft thrombosis is a serious complication of kidney transplantation that ultimately leads to graft loss. Its association with acute and hyperacute rejection is well documented; however, in a large proportion of patients the precise cause remains obscure. The exact incidence

  20. Modern thermodynamics

    CERN Document Server

    Ben-Naim, Arieh

    2017-01-01

    This textbook introduces thermodynamics with a modern approach, starting from four fundamental physical facts (the atomic nature of matter, the indistinguishability of atoms and molecules of the same species, the uncertainty principle, and the existence of equilibrium states) and analyzing the behavior of complex systems with the tools of information theory, in particular with Shannon's measure of information (or SMI), which can be defined on any probability distribution. SMI is defined and its properties and time evolution are illustrated, and it is shown that the entropy is a particular type of SMI, i.e. the SMI related to the phase-space distribution for a macroscopic system at equilibrium. The connection to SMI allows the reader to understand what entropy is and why isolated systems follow the Second Law of Thermodynamics. The Second Llaw is also formulated for other systems, not thermally isolated and even open with respect to the transfer of particles. All the fundamental aspects of thermodynamics are d...

  1. Modern electrodynamics

    CERN Document Server

    Zangwill, Andrew

    2013-01-01

    An engaging writing style and a strong focus on the physics make this comprehensive, graduate-level textbook unique among existing classical electromagnetism textbooks. Charged particles in vacuum and the electrodynamics of continuous media are given equal attention in discussions of electrostatics, magnetostatics, quasistatics, conservation laws, wave propagation, radiation, scattering, special relativity and field theory. Extensive use of qualitative arguments similar to those used by working physicists makes Modern Electrodynamics a must-have for every student of this subject. In 24 chapters, the textbook covers many more topics than can be presented in a typical two-semester course, making it easy for instructors to tailor courses to their specific needs. Close to 120 worked examples and 80 applications boxes help the reader build physical intuition and develop technical skill. Nearly 600 end-of-chapter homework problems encourage students to engage actively with the material. A solutions manual is availa...

  2. Aortic Graft Infection Secondary to Iatrogenic Transcolonic Graft Malposition.

    Science.gov (United States)

    Blank, Jacqueline J; Rothstein, Abby E; Lee, Cheong Jun; Malinowski, Michael J; Lewis, Brian D; Ridolfi, Timothy J; Otterson, Mary F

    2018-01-01

    Aortic graft infections are a rare but devastating complication of aortic revascularization. Often infections occur due to contamination at the time of surgery. Iatrogenic misplacement of the limbs of an aortobifemoral graft is exceedingly rare, and principles of evaluation and treatment are not well defined. We report 2 cases of aortobifemoral bypass graft malposition through the colon. Case 1 is a 54-year-old male who underwent aortobifemoral bypass grafting for acute limb ischemia. He had previously undergone a partial sigmoid colectomy for diverticulitis. Approximately 6 months after vascular surgery, he presented with an occult graft infection. Preoperative imaging and intraoperative findings were consistent with graft placement through the sigmoid colon. Case 2 is a 60-year-old male who underwent aortobifemoral bypass grafting due to a nonhealing wound after toe amputation. His postoperative course was complicated by pneumonia, bacteremia thought to be secondary to the pneumonia, general malaise, and persistent fevers. Approximately 10 weeks after the vascular surgery, he presented with imaging and intraoperative findings of graft malposition through the cecum. Aortic graft infection is usually caused by surgical contamination and presents as an indolent infection. Case 1 presented as such; Case 2 presented more acutely. Both grafts were iatrogenically misplaced through the colon at the index operation. The patients underwent extra-anatomic bypass and graft explantation and subsequently recovered.

  3. Summary of experimental insertions workshop

    International Nuclear Information System (INIS)

    Sandweiss, J.; Month, M.

    1976-01-01

    An ISABELLE workshop of the summer 1976 series, which was held at Brookhaven August 16--20, focused on the design and utilization of the experimental insertions. The goals of the workshop are outlined, and a few general remarks about the results are presented

  4. Concepts for stereoselective acrylate insertion

    KAUST Repository

    Neuwald, Boris

    2013-01-23

    Various phosphinesulfonato ligands and the corresponding palladium complexes [{((PaO)PdMeCl)-μ-M}n] ([{( X1-Cl)-μ-M}n], (PaO) = κ2- P,O-Ar2PC6H4SO2O) with symmetric (Ar = 2-MeOC6H4, 2-CF3C6H4, 2,6-(MeO)2C6H3, 2,6-(iPrO)2C 6H3, 2-(2′,6′-(MeO)2C 6H3)C6H4) and asymmetric substituted phosphorus atoms (Ar1 = 2,6-(MeO)2C6H 3, Ar2 = 2′-(2,6-(MeO)2C 6H3)C6H4; Ar1 = 2,6-(MeO)2C6H3, Ar2 = 2-cHexOC 6H4) were synthesized. Analyses of molecular motions and dynamics by variable temperature NMR studies and line shape analysis were performed for the free ligands and the complexes. The highest barriers of ΔGa = 44-64 kJ/mol were assigned to an aryl rotation process, and the flexibility of the ligand framework was found to be a key obstacle to a more effective stereocontrol. An increase of steric bulk at the aryl substituents raises the motional barriers but diminishes insertion rates and regioselectivity. The stereoselectivity of the first and the second methyl acrylate (MA) insertion into the Pd-Me bond of in situ generated complexes X1 was investigated by NMR and DFT methods. The substitution pattern of the ligand clearly affects the first MA insertion, resulting in a stereoselectivity of up to 6:1 for complexes with an asymmetric substituted phosphorus. In the consecutive insertion, the stereoselectivity is diminished in all cases. DFT analysis of the corresponding insertion transition states revealed that a selectivity for the first insertion with asymmetric (P aO) complexes is diminished in the consecutive insertions due to uncooperatively working enantiomorphic and chain end stereocontrol. From these observations, further concepts are developed. © 2012 American Chemical Society.

  5. Internal carotid artery rupture caused by carotid shunt insertion.

    Science.gov (United States)

    Illuminati, Giulio; Caliò, Francesco G; Pizzardi, Giulia; Vietri, Francesco

    2015-01-01

    Shunting is a well-accepted method of maintaining cerebral perfusion during carotid endarterectomy (CEA). Nonetheless, shunt insertion may lead to complications including arterial dissection, embolization, and thrombosis. We present a complication of shunt insertion consisting of arterial wall rupture, not reported previously. A 78-year-old woman underwent CEA combined with coronary artery bypass grafting (CABG). At the time of shunt insertion an arterial rupture at the distal tip of the shunt was detected and was repaired via a small saphenous vein patch. Eversion CEA and subsequent CABG completed the procedure whose postoperative course was uneventful. Shunting during combined CEA-CABG may be advisable to assure cerebral protection from possible hypoperfusion due to potential hemodynamic instability of patients with severe coronary artery disease. Awareness and prompt management of possible shunt-related complications, including the newly reported one, may contribute to limiting their harmful effect. Arterial wall rupture is a possible, previously not reported, shunt-related complication to be aware of when performing CEA. Copyright © 2015 The Authors. Published by Elsevier Ltd.. All rights reserved.

  6. The first LHC insertion quadrupole

    CERN Multimedia

    2004-01-01

    An important milestone was reached in December 2003 at the CERN Magnet Assembly Facility. The team from the Accelerator Technology - Magnet and Electrical Systems group, AT-MEL, completed the first special superconducting quadrupole for the LHC insertions which house the experiments and major collider systems. The magnet is 8 metres long and contains two matching quadrupole magnets and an orbit corrector, a dipole magnet, used to correct errors in quadrupole alignment. All were tested in liquid helium and reached the ultimate performance criteria required for the LHC. After insertion in the cryostat, the superconducting magnet will be installed as the Q9 quadrupole in sector 7-8, the first sector of the LHC to be put in place in 2004. Members of the quadrupole team, from the AT-MEL group, gathered around the Q9 quadrupole at its inauguration on 12 December 2003 in building 181.

  7. Insertion device calculations with mathematica

    Energy Technology Data Exchange (ETDEWEB)

    Carr, R. [Stanford Synchrotron Radiation Lab., CA (United States); Lidia, S. [Univ. of California, Davis, CA (United States)

    1995-02-01

    The design of accelerator insertion devices such as wigglers and undulators has usually been aided by numerical modeling on digital computers, using code in high level languages like Fortran. In the present era, there are higher level programming environments like IDL{reg_sign}, MatLab{reg_sign}, and Mathematica{reg_sign} in which these calculations may be performed by writing much less code, and in which standard mathematical techniques are very easily used. The authors present a suite of standard insertion device modeling routines in Mathematica to illustrate the new techniques. These routines include a simple way to generate magnetic fields using blocks of CSEM materials, trajectory solutions from the Lorentz force equations for given magnetic fields, Bessel function calculations of radiation for wigglers and undulators and general radiation calculations for undulators.

  8. Ring insertions as light sources

    International Nuclear Information System (INIS)

    Green, G.K.

    1975-01-01

    Bending magnets can be inserted in the long straight sections of electron storage rings to produce synchrotron radiation. If the design is carefully proportioned, the bending magnets create only a small perturbation of the properties of the ring. The resulting spectra have favorable optical properties as sources for spectroscopy and diffraction studies. The characteristics of the source are discussed, and the geometrical requirements of the magnets are presented

  9. Vacuum guidelines for ISA insertions

    International Nuclear Information System (INIS)

    Edwards, D. Jr.

    1976-01-01

    Vacuum requirements place design restrictions on the ISA insertions. The vacuum tube diameter, given a distance L between pumps, is determined by the desorption of molecules from the wall under the impact of ions created by the beam, whereas the thickness of the tube must be sufficient to prevent collapse. In addition, the entire vacuum chamber must be able to be baked out at approximately 200 0 C

  10. Inserts for nuclear fuel elements

    International Nuclear Information System (INIS)

    Cragg, P.J.

    1982-01-01

    An insert for a nuclear fuel pin which comprises a strip. The strip carries notches, which enable a coding arrangement to be carried on the strip. The notches may be of differing sizes and the coding on the strip includes identification and identification checking data. Each notch on the strip may give rise to a signal pulse which is counted by a detector to avoid errors. (author)

  11. ATLAS insertable B-layer

    Czech Academy of Sciences Publication Activity Database

    Marčišovský, Michal

    2011-01-01

    Roč. 633, č. 1 (2011), "S224"-"S225" ISSN 0168-9002. [International workshop on radiation imaging detectors /11./. Praha, 26.06.2009-02.07.2009] R&D Projects: GA MŠk LA08015; GA MŠk LA08032 Institutional research plan: CEZ:AV0Z10100502 Keywords : ATLAS * pixel detector * insertable B-layer Subject RIV: BF - Elementary Particles and High Energy Physics Impact factor: 1.207, year: 2011

  12. HTS Insert Magnet Design Study

    CERN Document Server

    Devaux, M; Fleiter, J; Fazilleau, P; Lécrevisse, T; Pes, C; Rey, J-M; Rifflet, J-M; Sorbi, M; Stenvall, A; Tixador, P; Volpini, G

    2011-01-01

    Future accelerator magnets will need to reach higher field in the range of 20 T. This field level is very difficult to reach using only Low Temperature Superconductor materials whereas High Temperature Superconductors (HTS) provide interesting opportunities. High current densities and stress levels are needed to design such magnets. YBCO superconductor indeed carries large current densities under high magnetic field and provides good mechanical properties especially when produced using the IBAD approach. The HFM EUCARD program studies the design and the realization of an HTS insert of 6 T inside a Nb$_{3}$Sn dipole of 13T at 4.2 K. In the2HTS insert, engineering current densities higher than 250 MA/m under 19 T are required to fulfill the specifications. The stress level is also very severe. YBCO IBAD tapes theoretically meet these challenges from presented measurements. The insert protection is also a critical because HTS materials show low quench propagation velocities and the coupling with the Nb$_{3}$Sn m...

  13. Vein grafting in fingertip replantations.

    Science.gov (United States)

    Yan, Hede; Jackson, William D; Songcharoen, Somjade; Akdemir, Ovunc; Li, Zhijie; Chen, Xinglong; Jiang, Liangfu; Gao, Weiyang

    2009-01-01

    In this retrospective study, the survival rates of fingertip replantation with and without vein grafting were evaluated along with their postoperative functional and cosmetic results. One hundred twenty-one-fingertip amputations were performed in 103 patients between September 2002 and July 2007. Thirty-four amputated fingertips were replanted without vein grafting, while 87 amputated fingertips were replanted with vein grafting for arterial and/or venous repairs. The overall survival rates of the replantations with and without vein grafting were 90% (78/87) and 85% (29/34), respectively. The survival rates were 88% (36/41) with venous repair, 93% (25/27) with arterial repair, and 89% (17/19) with both. Nineteen patients without vein grafting and 48 patients with vein grafting had a follow-up period of more than one year. Good cosmetic and functional outcomes were observed in both groups of patients. The results show that vein grafting is a reliable technique in fingertip replantations, showing no significant difference (P > 0.05) in survival between those with and without vein grafting. Furthermore, no significant difference (P > 0.05) in survival was found between cases with vein grafts for arterial and/or venous repairs. In fingertip replantations with vein grafting, favorable functional and esthetic results can be achieved without sacrificing replantation survival. (c) 2009 Wiley-Liss, Inc.

  14. The implantation of separating aortic stent-graft into the canine thoracic aorta: an experimental study

    International Nuclear Information System (INIS)

    Xia Jinguo; Shi Haibin; Yang Zhengqiang; Li Chao; Liu Sheng; Zu Qingquan; Li Linsun

    2011-01-01

    Objective: to assess the technical feasibility of implanting separating stent-graft into the canine thoracic aorta and to study its biocompatibility. Methods: Twelve adult dogs were randomly and equally divided into three groups. The right femoral artery was cut open, through which the separating stent-graft was inserted and deployed in the canine thoracic aorta, with the proximal end of the graft being quite close to the origin of the left subclavian artery. the technical feasibility of the deployment process was assessed. Angiography was performed at 4, 8 and 12 weeks after stent-graft placement to evaluate the position and patency of the stent-graft. Then the dogs were sacrificed and the specimens were collected for pathologic study. Both gross and microscopic examinations were made to evaluate the fixation of the stent-graft with the vessel wall, the endothelialization of stent-graft surface and the pathologic changes of the vascular wall. Results: A total of ten separating stent-grafts were successfully deployed in the canine thoracic aorta, no migration or deformation occurred. One dog died of massive bleeding due to the rupture of the right femoral artery which occurred when the delivery system containing the inner bare stent was inserted through the right femoral artery. Death occurred in another dog as a result of the ascending aorta rupture caused by the migration of outer-layer stent-graft. Angiography was conducted at 4, 8 and 12 weeks after stent-graft placement. No migration, deformation, rupture or stenosis of the implanted stent-grafts were observed. The formation of intima on the inner surface of the bare stent appeared at 4 weeks, which became more and more obvious with the time passing, and at 12 weeks complete endothelialization of stent-graft surface was observed. Conclusion: Technically, it is feasible to deploy the separating aortic stent-graft into the canine thoracic aorta. Moreover, the separating aortic stent-graft carries excellent

  15. Modern Supersymmetry

    International Nuclear Information System (INIS)

    Kulish, Petr P

    2006-01-01

    We have spent more than twenty years applying supersymmetry (SUSY) to elementary particle physics and attempting to find an experimental manifestation of this symmetry. Terning's monograph demonstrates the strong influence of SUSY on theoretical elaborations in the field of elementary particles. It gives both an overview of modern supersymmetry in elementary particle physics and calculation techniques. The author, trying to be closer to applications of SUSY in the real world of elementary particles, is also anticipating the importance of supersymmetry for rigorous study of nonperturbative phenomena in quantum field theory. In particular, he presents the 'exact' SUSY β function using instanton methods, phenomena of anomalies and dualities. Supersymmetry algebra is introduced by adding two anticommuting spinor generators to Poincare algebra and by presenting massive and massless supermultiplets of its representations. The author prefers to use mostly the component description of field contents of the theories in question rather than the superfield formalism. Such a style makes the account closer to physical characteristics. Relations required by SUSY among β functions of the gauge, Yukawa and quartic interactions are checked by direct calculations as well as to all orders in perturbation theory, thus demonstrating that SUSY survives quantization. A discussion is included of the hierarchy problem of different scales of weak and strong interactions and its possible solution by the minimal supersymmetric standard model. Different SUSY breaking mechanisms are presented corresponding to a realistic phenomenology. The monograph can also be considered as a guide to 'duality' relations connecting different SUSY gauge theories, supergravities and superstrings. This is demonstrated referring to the particular properties and characteristics of these theories (field contents, scaling dimensions of appropriate operators etc). In particular, the last chapter deals with the Ad

  16. Accuracy of secondary maxillofacial reconstruction with prefabricated fibula grafts using 3D planning and guided reconstruction

    NARCIS (Netherlands)

    Schepers, Rutger H.; Kraeima, Joep; Vissink, Arjan; Lahoda, Lars U.; Roodenburg, Jan L. N.; Reintsema, Harry; Raghoebar, Gerry M.; Witjes, Max J.

    Background: We compared the pre-operative 3D-surgical plan with the surgical outcome of complex two-stage secondary reconstruction of maxillofacial defects using inserted implants in the prefabricated fibula graft. Methods: Eleven reconstructions of maxillofacial defects with prefabricated fibulas

  17. Graft fixation with predetermined tension using a new device, the double spike plate.

    Science.gov (United States)

    Shino, Konsei; Mae, Tatsuo; Maeda, Akira; Miyama, Takahide; Shinjo, Hirotaka; Kawakami, Hideo

    2002-10-01

    To biomechanically evaluate a new fixation device, DSP (Double Spike Plate; Meira Corp, Nagoya, Aichi, Japan), for pullout graft fixation. Biomechanical study. A porcine tibia in which 8-mm diameter drill holes had been made from the medial tibial metaphysis to the anterior cruciate ligament attachment was rigidly fixed to a tension analyzer. A quadrupled graft consisting of 2 double-looped bovine tendons was prepared with No. 3 polyester sutures placed distally. The graft was passed through the drill hole, and its proximal loop ends were rigidly fixed to a load cell for monitoring graft tension. The graft's distal ends were connected to the DSP by tying the sutures to the top hole in the DSP. The graft tension was predetermined at 49 N (n = 5) or 98 N (n = 5). This tension was maintained for 5 minutes with a suture passed through the bottom hole of the DSP. The plate was fixed to the tibia by hammering its spikes into the bone under the index tension. Finally, the fixation was completed by inserting a screw. Although the graft tension immediately increased to 69 +/- 11 N or 133 +/- 14 N during hammering, it gradually reduced to 49 +/- 10 N or 100 +/- 7 N 5 minutes later. This study shows that graft fixation under a predetermined tension can be achieved with the DSP.

  18. Development of tissue-engineered self-expandable aortic stent grafts (Bio stent grafts) using in-body tissue architecture technology in beagles.

    Science.gov (United States)

    Kawajiri, Hidetake; Mizuno, Takeshi; Moriwaki, Takeshi; Ishibashi-Ueda, Hatsue; Yamanami, Masashi; Kanda, Keiichi; Yaku, Hitoshi; Nakayama, Yasuhide

    2015-02-01

    In this study, we aimed to describe the development of tissue-engineered self-expandable aortic stent grafts (Bio stent graft) using in-body tissue architecture technology in beagles and to determine its mechanical and histological properties. The preparation mold was assembled by insertion of an acryl rod (outer diameter, 8.6 mm; length, 40 mm) into a self-expanding nitinol stent (internal diameter, 9.0 mm; length, 35 mm). The molds (n = 6) were embedded into the subcutaneous pouches of three beagles for 4 weeks. After harvesting and removing each rod, the excessive fragile tissue connected around the molds was trimmed, and thus tubular autologous connective tissues with the stent were obtained for use as Bio stent grafts (outer diameter, approximately 9.3 mm in all molds). The stent strut was completely surrounded by the dense collagenous membrane (thickness, ∼150 µm). The Bio stent graft luminal surface was extremely flat and smooth. The graft wall of the Bio stent graft possessed an elastic modulus that was almost two times higher than that of the native beagle abdominal aorta. This Bio stent graft is expected to exhibit excellent biocompatibility after being implanted in the aorta, which may reduce the risk of type 1 endoleaks or migration. © 2014 Wiley Periodicals, Inc.

  19. Vascular graft infections with Mycoplasma

    DEFF Research Database (Denmark)

    Levi-Mazloum, Niels Donald; Skov Jensen, J; Prag, J

    1995-01-01

    laboratory techniques, the percentage of culture-negative yet grossly infected vascular grafts seems to be increasing and is not adequately explained by the prior use of antibiotics. We have recently reported the first case of aortic graft infection with Mycoplasma. We therefore suggest the hypothesis...... that the large number of culture-negative yet grossly infected vascular grafts may be due to Mycoplasma infection not detected with conventional laboratory technique....

  20. Field errors in hybrid insertion devices

    International Nuclear Information System (INIS)

    Schlueter, R.D.

    1995-02-01

    Hybrid magnet theory as applied to the error analyses used in the design of Advanced Light Source (ALS) insertion devices is reviewed. Sources of field errors in hybrid insertion devices are discussed

  1. Field errors in hybrid insertion devices

    Energy Technology Data Exchange (ETDEWEB)

    Schlueter, R.D. [Lawrence Berkeley Lab., CA (United States)

    1995-02-01

    Hybrid magnet theory as applied to the error analyses used in the design of Advanced Light Source (ALS) insertion devices is reviewed. Sources of field errors in hybrid insertion devices are discussed.

  2. Environmental application of radiation grafting

    International Nuclear Information System (INIS)

    Tamada, Masao

    2007-01-01

    Adsorbent having high selectivity against a certain metal ion was synthesized by means of radiation-induced graft polymerization for the purpose of environmental application. The resulting adsorbents were utilized for the removal of toxic metal from scallop waste and the collection of uranium from seawater. As a novel application of grafting, the biodegradability of poly-hydroxybutylate was controlled by grafting. The biodegradability could be depressed by the graft chain and then recovered by external stimuli such as thermal and chemical treatments. (author)

  3. Regional insertion: an emergent approach

    International Nuclear Information System (INIS)

    Serra, M.T.F.; Nascimento Teixeira, P. do

    1989-01-01

    The Brazilian Electrical Sector incorporates new variables that expressing the extensive spectrum of environmental impacts in the take of decisions, referring to the viability of realizing a electrical undertaking, attends the several restrictions that are important by the sector and by the society in the environment area and promotes the adequate generation of liquid benefits, consequential of the electrical undertaking. Due to these factors, the Electrical Sector is improving the concept of regional insertion, with the sectorial expansion in long-dated and the created demand in the environmental and social area, focalizing the solution for these questions. (C.G.C.). 1 fig, 2 tabs

  4. Recent advances in insertion devices

    International Nuclear Information System (INIS)

    Gluskin, E.; Moog, E.R.

    1995-01-01

    Demand for more and better insertion devices (IDs) at new third-generation synchrotron radiation facilities has led to significant advances in ID technology at different laboratories around the world. In this overview of this progress, focus is on those results that apply to IDs in general rather than one specific ID or laboratory. The advances fall into two general categories: those that reduce the net effect that the ID has on the particle beam, and those that enhance the quality of the emitted light spectrum. The need for these advances, factors that are most important inaachieving them, and the current state of the art are discussed

  5. Summary of experimental insertions workshop

    International Nuclear Information System (INIS)

    Sandweiss, J.; Month, M.

    1976-01-01

    The last ISABELLE workshop of the summer 1976 series, which was held at Brookhaven, August 16-20, focused on the design and utilization of the experimental insertions. The goals of the workshop, which were somewhat more general than might be suggested by the title, are: (1) review the ISABELLE proposal from the point of view of experimental use; (2) contribute useful information on the ''open questions'' in the ISABELLE design; (3) develop data for experimental equipment and operating cost estimates; and (4) project a first approximation to ISABELLE operating modes

  6. Grafting the alar rim: application as anatomical graft.

    Science.gov (United States)

    Gruber, Ronald P; Fox, Paige; Peled, Anne; Belek, Kyle A

    2014-12-01

    Alar rim contour and alar rim grafts have become essential components of rhinoplasty. Ideally, grafts of the nose should be anatomical in shape. So doing might make grafts of the alar rim more robust. The authors considered doing that by applying the graft as a continuous extension of the lateral crus. Twelve patients (two men and 10 women) constituted the study group (seven primary and five secondary cases). Of those, there were five concave rims, two concave rims with rim retraction, two boxy tips, and three cephalically oriented lateral crura. Surgical technique included the following: (1) an open approach was used; (2) a marginal incision that ignored the caudal margin of the lateral crus (the incision went straight posteriorly to a point 5 to 6 mm from the rim margin) was used; (3) a triangular graft was made to cover the exposed vestibular skin; (4) it was secured end to end to the caudal border of the lateral crus; and (5) the poster end was allowed to sit in a small subcutaneous pocket. Follow-up was 11 to 19 months. All 12 patients exhibited good rims as judged by a blinded panel. Rim retraction was not fully corrected in one patient, but no further treatment was required. One patient did require a secondary small rim graft for residual rim concavity. The concept of grafting the alar rim is strongly supported by the authors' results. The modifications the authors applied by designing the graft to be anatomical in shape has been a technical help.

  7. Insertion and crossing region design

    International Nuclear Information System (INIS)

    Wienands, U.; Beloshitsky, P.

    2001-01-01

    This article is the summary of the 5-afternoon tutorial on insertions for circular machines. Roughly half the course (Part 1) was spent discussing interaction regions, We start by recapitulating basic beam optics including building blocks. This provides the tools to analyze the basic structure of interaction regions and explore the parameter space. This simple example is then successively refined and made more realistic. Examples of realized interaction regions for both hadron and electron machines are shown and their salient features and differences explained. A brief discussion of solenoid-decoupling brings Part 1 to a close. In Part 2 we discussed various utility sections. Dispersion suppressors are presented in detail discussing the principles as well as the practical implementation of flexible suppressors using LEP as an example. Injection schemes, both single-turn and multi-turn stacking, are presented in depth. The matching of wiggler and undulator insertions and a discussion of the impact of these devices on beam parameters closes out Part 2

  8. Suction blister grafting - Modifications for easy harvesting and grafting

    Directory of Open Access Journals (Sweden)

    2012-01-01

    Full Text Available Suction blister grafting is a simple modality of treatment of patients with resistant and stable vitiligo. But raising the blisters may be time consuming and transferring to the recipient site may be difficult as the graft is ultrathin. By doing some modifications we can make the technique simpler and easier. We can decrease the blister induction time by intradermal injection of saline, exposure to Wood′s lamp, intrablister injection of saline. By these methods we can decrease the blister induction time from 2-3 hrs to 45-90 minutes. After harvesting the graft, it can be transferred to the recipient area by taking the graft on a sterile glass slide, on the gloved finger, rolling the graft over a sterile syringe and then spreading on the recipient area, or taking on the sterile wrapper of paraffin dressing and then placing over the recipient area.

  9. Multiple modernities, modern subjectivities and social order

    DEFF Research Database (Denmark)

    Jung, Dietrich; Sinclair, Kirstine

    2015-01-01

    to modern subjectivity formation. In combining conceptual tools from these strands of social theory, we argue that the emergence of multiple modernities should be understood as a historical result of idiosyncratic social constructions combining global social imaginaries with religious and other cultural......Taking its point of departure in the conceptual debate about modernities in the plural, this article presents a heuristic framework based on an interpretative approach to modernity. The article draws on theories of multiple modernities, successive modernities and poststructuralist approaches...... traditions. In the second part of the article we illustrate this argument with three short excursions into the history of Islamic reform in the 19th and 20th centuries. In this way we interpret the modern history of Muslim societies as based on cultural conflicts between different forms of social order...

  10. Intraoperative fat embolism during core decompression and bone grafting for osteonecrosis of the hip: report of 3 cases and literature review.

    Science.gov (United States)

    Schaffer, Joseph Christopher; Adib, Farshad; Cui, Quanjun

    2014-06-01

    Osteonecrosis (ON) of the femoral head, without timely intervention, often progresses to debilitating hip arthritis. Core decompression (CD) with bone grafting was used to treat patients with early-stage ON. In 3 cases, intraoperative oxygen saturation, end-tidal carbon dioxide fluctuations, and/or vital sign fluctuations were observed during insertion of the graft, a mixture of bone marrow and demineralized bone matrix. In 1 case, continued postoperative pulmonary symptoms required admission to intensive care. In this article, we describe these cases and provide supporting evidence that they were caused by fat emboli secondary to forceful insertion of bone graft. We review the literature and present complications data. Although no cases of fat emboli were reported as complications of any CD series with or without bone grafting, CD augmented with bone graft may carry risks not seen before in CD alone. Care should be taken to avoid these complications, possibly through technique modification.

  11. The kinetics of porous insertion electrodes

    Energy Technology Data Exchange (ETDEWEB)

    Atlung, S; West, K [British Columbia Univ., Vancouver (Canada)

    1989-05-01

    The principles of porous electrodes are discussed as well as the discharge of the insertion compound, the working potential, transport in the electrolyte, the time dependence of the electrolyte concentration, and modeling of the porous electrode. The simulation of a TiS2 porous electrode and the composite insertion electrode are considered as well. The influence of electrode thickness and porosity in a typical porous TiS2 electrode is revealed. It is shown that the use of insertion compounds as battery electrodes is limited by the requirement that the inserted ion must be distributed in the interior of the insertion compound particle. 15 refs.

  12. SOME TECHNIQUES IN CORNEAL GRAFTING

    African Journals Online (AJOL)

    1971-04-10

    Apr 10, 1971 ... current herpes corneae. The visual acuity was less than. 6/60. The left eye had had a central nebula since child- hood and was deemed amblyopic. Six weeks after a 7 x 0·3 mm lamellar graft in the right eye was placed, ulceration occurred in the graft junction. A total thin conjunctival flap was sutured over.

  13. Polyether/Polyester Graft Copolymers

    Science.gov (United States)

    Bell, Vernon L., Jr.; Wakelyn, N.; Stoakley, D. M.; Proctor, K. M.

    1986-01-01

    Higher solvent resistance achieved along with lower melting temperature. New technique provides method of preparing copolymers with polypivalolactone segments grafted onto poly (2,6-dimethyl-phenylene oxide) backbone. Process makes strong materials with improved solvent resistance and crystalline, thermally-reversible crosslinks. Resulting graft copolymers easier to fabricate into useful articles, including thin films, sheets, fibers, foams, laminates, and moldings.

  14. The United States Army 1996 Modernization Plan.

    Science.gov (United States)

    1996-03-08

    time and with less risk. IMA technology improvements are leveraged and inserted into the Army’s information architectures as the competitive market place...to procure a family of complementary, interoperable systems. At the end of the near-term, "Active Defense RD&A Startegy Army will begin fielding...Haul and Engineer tractors were fielded that brought modern technologies from the commercial market to the Army. However, adequate quantities were

  15. Development of parietal bone surrogates for parietal graft lift training

    Directory of Open Access Journals (Sweden)

    Hollensteiner Marianne

    2016-09-01

    Full Text Available Currently the surgical training of parietal bone graft techniques is performed on patients or specimens. Commercially available bone models do not deliver realistic haptic feedback. Thus customized parietal skull surrogates were developed for surgical training purposes. Two human parietal bones were used as reference. Based on the measurement of insertion forces of drilling, milling and saw procedures suitable material compositions for molding cortical and cancellous calvarial layers were found. Artificial skull caps were manufactured and tested. Additionally microtomograpy images of human and artificial parietal bones were performed to analyze outer table and diploe thicknesses. Significant differences between human and artificial skulls were not detected with the mechanical procedures tested. Highly significant differences were found for the diploe thickness values. In conclusion, an artificial bone has been created, mimicking the properties of human parietal bone thus being suitable for tabula externa graft lift training.

  16. Radiation grafting on natural films

    Science.gov (United States)

    Lacroix, M.; Khan, R.; Senna, M.; Sharmin, N.; Salmieri, S.; Safrany, A.

    2014-01-01

    Different methods of polymer grafting using gamma irradiation are reported in the present study for the preparation of newly functionalized biodegradable films, and some important properties related to their mechanical and barrier properties are described. Biodegradable films composed of zein and poly(vinyl alcohol) (PVA) were gamma-irradiated in presence of different ratios of acrylic acid (AAc) monomer for compatibilization purpose. Resulting grafted films (zein/PVA-g-AAc) had their puncture strength (PS=37-40 N mm-1) and puncture deformation (PD=6.5-9.8 mm) improved for 30% and 50% PVA in blend, with 5% AAc under 20 kGy. Methylcellulose (MC)-based films were irradiated in the presence of 2-hydroxyethyl methacrylate (HEMA) or silane, in order to determine the effect of monomer grafting on the mechanical properties of films. It was found that grafted films (MC-g-HEMA and MC-g-silane) using 35% monomer performed higher mechanical properties with PS values of 282-296 N mm-1 and PD of 5.0-5.5 mm under 10 kGy. Compatibilized polycaprolactone (PCL)/chitosan composites were developed via grafting silane in chitosan films. Resulting trilayer grafted composite film (PCL/chitosan-g-silane/PCL) presented superior tensile strength (TS=22 MPa) via possible improvement of interfacial adhesion (PCL/chitosan) when using 25% silane under 10 kGy. Finally, MC-based films containing crystalline nanocellulose (CNC) as a filling agent were prepared and irradiated in presence of trimethylolpropane trimethacrylate (TMPTMA) as a grafted plasticizer. Grafted films (MC-g-TMPTMA) presented superior mechanical properties with a TS of 47.9 MPa and a tensile modulus (TM) of 1792 MPa, possibly due to high yield formation of radicals to promote TMPTMA grafting during irradiation. The addition of CNC led to an additional improvement of the barrier properties, with a significant 25% reduction of water vapor permeability (WVP) of grafted films.

  17. The Effect of Insertion Technique on Temperatures for Standard and Self-Drilling External Fixation Pins.

    Science.gov (United States)

    Manoogian, Sarah; Lee, Adam K; Widmaier, James C

    2017-08-01

    No studies have assessed the effects of parameters associated with insertion temperature in modern self-drilling external fixation pins. The current study assessed how varying the presence of irrigation, insertion speed, and force impacted the insertion temperatures of 2 types of standard and self-drilling external fixation half pins. Seventy tests were conducted with 10 trials for 4 conditions on self-drilling pins, and 3 conditions for standard pins. Each test used a thermocouple inside the pin to measure temperature rise during insertion. Adding irrigation to the standard pin insertion significantly lowered the maximum temperature (P drilling pin tests dropped average rise in temperature from 151.3 ± 21.6°C to 124.1 ± 15.3°C (P = 0.005). When the self-drilling pin insertion was decreased considerably from 360 to 60 rpm, the temperature decreased significantly from 151.3 ± 21.6°C to 109.6 ± 14.0°C (P drilling pin temperature increase was not significant. The standard pin had lower peak temperatures than the self-drilling pin for all conditions. Moreover, slowing down the insertion speed and adding irrigation helped mitigate the temperature increase of both pin types during insertion.

  18. Pediatric burn wound impetigo after grafting.

    Science.gov (United States)

    Aikins, Kimberly; Prasad, Narayan; Menon, Seema; Harvey, John G; Holland, Andrew J A

    2015-01-01

    Modern burn care techniques have reduced the risk of infection of the acute burn wound, resulting in more rapid healing and a lower incidence of graft loss. Secondary breakdown may still occur. The loss of epithelium in association with multifocal superficial abscesses and ulceration has been termed burns impetigo. This may result in considerable morbidity and require prolonged treatment. The events preceding development, the impact on the patient, and the ideal treatment appear unclear and poorly reported. In 5 years, between 2006 and 2011, 406 pediatric burns were treated with skin grafts, with 7% developing burns impetigo. Time to resolution ranged from 5 to 241 days: the mean time to complete healing was greatest with conservative management (96 days), followed by antibacterial dressings (37 days), oral antibiotics (36 days), topical steroids (16 days), and oral antibiotics in combination with topical steroids (13.5 days). Burns impetigo resulted in significant morbidity, requiring multiple visits to the treatment center and prolonged symptoms. Delay in diagnosis and treatment resulted in worse outcomes. Prompt consideration of burns impetigo should occur when postgraft patients present with suggestive clinical signs and treatment with oral antibiotics plus topical steroids should be considered.

  19. Cleaning Insertions and Collimation Challenges

    Science.gov (United States)

    Redaelli, S.; Appleby, R. B.; Bertarelli, A.; Bruce, R.; Jowett, J. M.; Lechner, A.; Losito, R.

    High-performance collimation systems are essential for operating efficiently modern hadron machine with large beam intensities. In particular, at the LHC the collimation system ensures a clean disposal of beam halos in the superconducting environment. The challenges of the HL-LHC study pose various demanding requests for beam collimation. In this paper we review the present collimation system and its performance during the LHC Run 1 in 2010-2013. Various collimation solutions under study to address the HL-LHC requirements are then reviewed, identifying the main upgrade baseline and pointing out advanced collimation concept for further enhancement of the performance.

  20. Temporary placement of stent grafts in postsurgical benign biliary strictures: a single center experience.

    Science.gov (United States)

    Vellody, Ranjith; Willatt, Jonathon M; Arabi, Mohammad; Cwikiel, Wojciech B

    2011-01-01

    To evaluate the effect of temporary stent graft placement in the treatment of benign anastomotic biliary strictures. Nine patients, five women and four men, 22-64 years old (mean, 47.5 years), with chronic benign biliary anastomotic strictures, refractory to repeated balloon dilations, were treated by prolonged, temporary placement of stent-grafts. Four patients had strictures following a liver transplantation; three of them in bilio-enteric anastomoses and one in a choledocho-choledochostomy. Four of the other five patients had strictures at bilio-enteric anastomoses, which developed after complications following laparoscopic cholecystectomies and in one after a Whipple procedure for duodenal carcinoma. In eight patients, balloon-expandable stent-grafts were placed and one patient was treated by insertion of a self-expanding stent-graft. In the transplant group, treatment of patients with bilio-enteric anastomoses was unsuccessful (mean stent duration, 30 days). The patient treated for stenosis in the choledocho-choledochostomy responded well to consecutive self-expanding stent-graft placement (total placement duration, 112 days). All patients with bilio-enteric anastomoses in the non-transplant group were treated successfully with stent-grafts (mean placement duration, 37 days). Treatment of benign biliary strictures with temporary placement of stent-grafts has a positive effect, but is less successful in patients with strictures developed following a liver transplant.

  1. Temporary Placement of Stent Grafts in Postsurgical Benign Biliary Strictures: a Single Center Experience

    Energy Technology Data Exchange (ETDEWEB)

    Vellody, Ranjith; Willatt, Jnonathon M.; Arabi, Mohammad; Cwikiel, Wojciech B [Division of Interventional Radiology, University of Michigan, Ann Arbor (United States)

    2011-11-15

    To evaluate the effect of temporary stent graft placement in the treatment of benign anastomotic biliary strictures. Nine patients, five women and four men, 22-64 years old (mean, 47.5 years), with chronic benign biliary anastomotic strictures, refractory to repeated balloon dilations, were treated by prolonged, temporary placement of stent-grafts. Four patients had strictures following a liver transplantation; three of them in bilio-enteric anastomoses and one in a choledocho-choledochostomy. Four of the other five patients had strictures at bilio-enteric anastomoses, which developed after complications following laparoscopic cholecystectomies and in one after a Whipple procedure for duodenal carcinoma. In eight patients, balloon-expandable stent-grafts were placed and one patient was treated by insertion of a self-expanding stent-graft. In the transplant group, treatment of patients with bilio-enteric anastomoses was unsuccessful (mean stent duration, 30 days). The patient treated for stenosis in the choledocho-choledochostomy responded well to consecutive self-expanding stent-graft placement (total placement duration, 112 days). All patients with bilio-enteric anastomoses in the non-transplant group were treated successfully with stent-grafts (mean placement duration, 37 days). Treatment of benign biliary strictures with temporary placement of stent-grafts has a positive effect, but is less successful in patients with strictures developed following a liver transplant.

  2. Temporary Placement of Stent Grafts in Postsurgical Benign Biliary Strictures: a Single Center Experience

    International Nuclear Information System (INIS)

    Vellody, Ranjith; Willatt, Jnonathon M.; Arabi, Mohammad; Cwikiel, Wojciech B

    2011-01-01

    To evaluate the effect of temporary stent graft placement in the treatment of benign anastomotic biliary strictures. Nine patients, five women and four men, 22-64 years old (mean, 47.5 years), with chronic benign biliary anastomotic strictures, refractory to repeated balloon dilations, were treated by prolonged, temporary placement of stent-grafts. Four patients had strictures following a liver transplantation; three of them in bilio-enteric anastomoses and one in a choledocho-choledochostomy. Four of the other five patients had strictures at bilio-enteric anastomoses, which developed after complications following laparoscopic cholecystectomies and in one after a Whipple procedure for duodenal carcinoma. In eight patients, balloon-expandable stent-grafts were placed and one patient was treated by insertion of a self-expanding stent-graft. In the transplant group, treatment of patients with bilio-enteric anastomoses was unsuccessful (mean stent duration, 30 days). The patient treated for stenosis in the choledocho-choledochostomy responded well to consecutive self-expanding stent-graft placement (total placement duration, 112 days). All patients with bilio-enteric anastomoses in the non-transplant group were treated successfully with stent-grafts (mean placement duration, 37 days). Treatment of benign biliary strictures with temporary placement of stent-grafts has a positive effect, but is less successful in patients with strictures developed following a liver transplant.

  3. A different and safe method of split thickness skin graft fixation: medical honey application.

    Science.gov (United States)

    Emsen, Ilteris Murat

    2007-09-01

    Honey has been used for medicinal purposes since ancient times. Its antibacterial effects have been established during the past few decades. Still, modern medical practitioners hesitate to apply honey for local treatment of wounds. This may be because of the expected messiness of such local application. Hence, if honey is to be used for medicinal purposes, it has to meet certain criteria. The authors evaluated its use for the split thickness skin graft fixation because of its adhesive and other beneficial effects in 11 patients. No complications such as graft loss, infection, and graft rejection were seen. Based on these results, the authors advised honey as a new agent for split thickness skin graft fixation. In recent years there has been a renewed interest in honey wound management. There are a range of regulated wound care products that contain honey available on the Drug Tariff. This article addresses key issues associated with the use of honey, outlining how it may be best used, in which methods of split thickness skin graft fixations it may be used, and what clinical outcomes may be anticipated. For this reason, 11 patients who underwent different diagnosis were included in this study. In all the patients same medical honey was used for the fixation of the skin graft. No graft loss was seen during both the first dressing and the last view of the grafted areas. As a result, it has been shown that honey is also a very effective agent for split thickness skin graft fixations. Because it is a natural agent, it can be easily used in all skin graft operation for the fixation of the split thickness skin grafts.

  4. Graft intolerance syndrome requiring graft nephrectomy after late kidney graft failure: can it be predicted? A retrospective cohort study.

    Science.gov (United States)

    Bunthof, Kim L W; Verhoeks, Carmen M; van den Brand, Jan A J G; Hilbrands, Luuk B

    2018-02-01

    Graft nephrectomy is recommended in case of early graft failure. When the graft fails more than 3-6 months after transplantation, it is current practice to follow a wait-and-see policy. A common indication for graft removal is the graft intolerance syndrome. We aimed to create a risk prediction model for the occurrence of graft intolerance resulting in graft nephrectomy. We collected data of kidney transplantations performed in our center between 1980 and 2010 that failed at least 6 months after transplantation. We evaluated the association between baseline characteristics and the occurrence of graft nephrectomy because of graft intolerance using a competing risk regression model. Prognostic factors were included in a multivariate prediction model. In- and exclusion criteria were met in 288 cases. In 48 patients, the graft was removed because of graft intolerance. Donor age, the number of rejections, and shorter graft survival were predictive factors for graft nephrectomy because of the graft intolerance syndrome. These factors were included in a prediction rule. Using donor age, graft survival, and the number of rejections, clinicians can predict the need for graft nephrectomy with a reasonable accuracy. © 2017 Steunstichting ESOT.

  5. Backside wear in modern total knee designs.

    Science.gov (United States)

    Jayabalan, Prakash; Furman, Bridgette D; Cottrell, Jocelyn M; Wright, Timothy M

    2007-02-01

    Although modularity affords various options to the orthopedic surgeon, these benefits come at a price. The unintended bearing surface between the back surface of the tibial insert and the metallic tray results in micromotion leading to polyethylene wear debris. The objective of this study was to examine the backside wear of tibial inserts from three modern total knee designs with very different locking mechanisms: Insall-Burstein II (IB II), Optetrak, and Advance. A random sample of 71 inserts were obtained from our institution's retrieval collection and examined to assess the extent of wear, depth of wear, and wear damage modes. Patient records were also obtained to determine patient age, body mass index, length of implantation, and reason for revision. Modes of wear damage (abrasion, burnishing, scratching, delamination, third body debris, surface deformation, and pitting) were then scored in each zone from 0 to 3 (0 = 0%, 1 = 0-10%, 2 = 10-50%, and 3 = >50%). The depth of wear was subjectively identified as removal of manufacturing identification markings stamped onto the inferior surface of the polyethylene. Both Advance and IB II polyethylene inserts showed significantly higher scores for backside wear than the Optetrak inserts. All IB II and Advance implants showed evidence of backside wear, whereas 17% (5 out of 30) of the retrieved Optetrak implants had no observable wear. There were no significant differences when comparing the depth of wear score between designs. The locking mechanism greatly affects the propensity for wear and should be considered when choosing a knee implant system.

  6. Sequential cooling insert for turbine stator vane

    Science.gov (United States)

    Jones, Russel B

    2017-04-04

    A sequential flow cooling insert for a turbine stator vane of a small gas turbine engine, where the impingement cooling insert is formed as a single piece from a metal additive manufacturing process such as 3D metal printing, and where the insert includes a plurality of rows of radial extending impingement cooling air holes alternating with rows of radial extending return air holes on a pressure side wall, and where the insert includes a plurality of rows of chordwise extending second impingement cooling air holes on a suction side wall. The insert includes alternating rows of radial extending cooling air supply channels and return air channels that form a series of impingement cooling on the pressure side followed by the suction side of the insert.

  7. Cartilage grafting in nasal reconstruction.

    Science.gov (United States)

    Immerman, Sara; White, W Matthew; Constantinides, Minas

    2011-02-01

    Nasal reconstruction after resection for cutaneous malignancies poses a unique challenge to facial plastic surgeons. The nose, a unique 3-D structure, not only must remain functional but also be aesthetically pleasing to patients. A complete understanding of all the layers of the nose and knowledge of available cartilage grafting material is necessary. Autogenous material, namely septal, auricular, and costal cartilage, is the most favored material in a free cartilage graft or a composite cartilage graft. All types of material have advantages and disadvantages that should guide the most appropriate selection to maximize the functional and cosmetic outcomes for patients. Copyright © 2011 Elsevier Inc. All rights reserved.

  8. Insertion devices at the advanced photon source

    International Nuclear Information System (INIS)

    Moog, E.R.

    1996-01-01

    The insertion devices being installed at the Advanced Photon Source cause the stored particle beam to wiggle, emitting x-rays with each wiggle. These x-rays combine to make an intense beam of radiation. Both wiggler and undulator types of insertion devices are being installed; the characteristics of the radiation produced by these two types of insertion devices are discussed, along with the reasons for those characteristics

  9. Node insertion in Coalescence Fractal Interpolation Function

    International Nuclear Information System (INIS)

    Prasad, Srijanani Anurag

    2013-01-01

    The Iterated Function System (IFS) used in the construction of Coalescence Hidden-variable Fractal Interpolation Function (CHFIF) depends on the interpolation data. The insertion of a new point in a given set of interpolation data is called the problem of node insertion. In this paper, the effect of insertion of new point on the related IFS and the Coalescence Fractal Interpolation Function is studied. Smoothness and Fractal Dimension of a CHFIF obtained with a node are also discussed

  10. Inheritance of graft compatibility in Douglas fir.

    Science.gov (United States)

    D.L. Copes

    1973-01-01

    Graft compatibility of genetically related and unrelated rootstock-scion combinations was compared. Scion clones were 75% compatible when grafted on half-related rootstocks but only 56% compatible when grafted on unrelated rootstocks. Most variance associated with graft incompatibility in Douglas-fir appears to be caused by multiple genes.

  11. Graft union formation in Douglas-fir.

    Science.gov (United States)

    D.L. Copes

    1969-01-01

    Greenhouse-grown Douglas-fir (Pseudotsuga menziesii [Mirb.] Franco) graft unions were examined between 2 and 84 days after grafting. Room temperature was maintained at 60-70 F throughout the growing season. In most respects grafts of Douglas-fir followed development patterns previously reported for spruce and pine grafts, but specific differences...

  12. Survival of Skin Graft between Transgenic Cloned Dogs and Non-Transgenic Cloned Dogs

    Science.gov (United States)

    Kim, Geon A; Oh, Hyun Ju; Kim, Min Jung; Jo, Young Kwang; Choi, Jin; Park, Jung Eun; Park, Eun Jung; Lim, Sang Hyun; Yoon, Byung Il; Kang, Sung Keun; Jang, Goo; Lee, Byeong Chun

    2014-01-01

    Whereas it has been assumed that genetically modified tissues or cells derived from somatic cell nuclear transfer (SCNT) should be accepted by a host of the same species, their immune compatibility has not been extensively explored. To identify acceptance of SCNT-derived cells or tissues, skin grafts were performed between cloned dogs that were identical except for their mitochondrial DNA (mtDNA) haplotypes and foreign gene. We showed here that differences in mtDNA haplotypes and genetic modification did not elicit immune responses in these dogs: 1) skin tissues from genetically-modified cloned dogs were successfully transplanted into genetically-modified cloned dogs with different mtDNA haplotype under three successive grafts over 63 days; and 2) non-transgenic cloned tissues were accepted into transgenic cloned syngeneic recipients with different mtDNA haplotypes and vice versa under two successive grafts over 63 days. In addition, expression of the inserted gene was maintained, being functional without eliciting graft rejection. In conclusion, these results show that transplanting genetically-modified tissues into normal, syngeneic or genetically-modified recipient dogs with different mtDNA haplotypes do not elicit skin graft rejection or affect expression of the inserted gene. Therefore, therapeutically valuable tissue derived from SCNT with genetic modification might be used safely in clinical applications for patients with diseased tissues. PMID:25372489

  13. Insertion material for controlling reactivity

    International Nuclear Information System (INIS)

    Baba, Iwao.

    1994-01-01

    Moderators and a group of suspended materials having substantially the same density as the moderator are sealed in a hollow rod vertically inserted to a fuel assembly. Specifically, the group of suspended materials is adapted to have a density changing stepwise from density of the moderator at the exit temperature of the reactor core to that at the inlet temperature of the reactor core. Reactivity is selectively controlled for a portion of high power and a portion of high reactivity by utilizing the density of the moderator and the distribution of the density. That is, if the power distribution is flat, the density of the moderators changes at a constant rate over the vertical direction of the reactor core and the suspended materials stay at a portion of the same density, to form a uniform distribution. Further, upon reactor shutdown, since the liquid temperature of the moderators is lowered and the density is increased, all of beads are collected at the upper portion to remove water at the upper portion of the reactor core of low burnup degree thereby selectively controlling the reactivity at a portion of high power and a portion of high reactivity. (N.H.)

  14. Fat Grafting for Facial Filling and Regeneration.

    Science.gov (United States)

    Coleman, Sydney R; Katzel, Evan B

    2015-07-01

    Plastic surgeons have come to realize that fat grafting can rejuvenate an aging face by restoring or creating fullness. However, fat grafting does much more than simply add volume. Grafted fat can transform or repair the tissues into which it is placed. Historically, surgeons have hesitated to embrace the rejuvenating potential of fat grafting because of poor graft take, fat necrosis, and inconsistent outcomes. This article describes fat grafting techniques and practices to assist readers in successful harvesting, processing, and placement of fat for optimal graft retention and facial esthetic outcomes. Copyright © 2015 Elsevier Inc. All rights reserved.

  15. Design of a Sapling Branch Grafting Robot

    Directory of Open Access Journals (Sweden)

    Qun Sun

    2014-01-01

    Full Text Available The automatic sapling grafting methods and grafting robot technologies are not comprehensively studied despite the fact that they are urgently required in practice. For this reason, a sapling grafting robot is developed to implement automatic grafting for saplings. The developed grafting robot includes clipping mechanism, moving mechanism, cutting mechanism, binding mechanism, and Arduino MCU based control system, which is capable of clipping, moving, positioning, cutting, grafting, and binding saplings. Experiments show that the stock cutting efficiency is 98.4%, the scion cutting efficiency is 98.9%, the grafting efficiency is 87.3%, and the binding efficiency is 68.9%.

  16. Hydrophilic/hydrophobic character of grafted cellulose

    Energy Technology Data Exchange (ETDEWEB)

    Takacs, E., E-mail: takacs@iki.kfki.h [Institute of Isotopes, Hungarian Academy of Sciences, Budapest (Hungary); Wojnarovits, L. [Institute of Isotopes, Hungarian Academy of Sciences, Budapest (Hungary); Borsa, J. [Budapest University of Technology and Economics (Hungary); Racz, I. [Bay Zoltan Institute for Materials Science and Technology, Budapest (Hungary)

    2010-04-15

    Vinyl monomers with long paraffin chains were grafted onto two kinds of cellulose (cotton and cotton linter) by direct irradiation grafting technique. The effect of dose, monomer structure and concentration, as well as homopolymer suppressor (styrene) concentration on the grafting yield was studied and the optimal grafting conditions were established. Grafting decreased the swelling of the samples in water and increased their polymer compatibility in polypropylene matrix.

  17. Percutaneous Endoluminal Stent-Graft Repair of an Old Traumatic Femoral Arteriovenous Fistula

    International Nuclear Information System (INIS)

    Uflacker, Renan; Elliott, Bruce M.

    1996-01-01

    A stent-graft was custom made to close a high-flow traumatic arteriovenous fistula of the left superficial femoral artery, present for 30 years, in a 60-year-old man with congestive heart failure and ischemic ulceration in the left foot. A balloon expandable Palmaz stent (P394; 2.5 mm x 3.9 cm) was covered with a polytetrafluoroethylene (PTFE) graft and was inserted percutaneously through an 11 Fr vascular sheath. Follow-up Doppler ultrasound at 6 months demonstrated occlusion of the arteriovenous fistula, patency of the artery, and luminal integrity of the artery and vein

  18. Air Pump-Assisted Graft Centration, Graft Edge Unfolding, and Graft Uncreasing in Young Donor Graft Pre-Descemet Endothelial Keratoplasty.

    Science.gov (United States)

    Jacob, Soosan; Narasimhan, Smita; Agarwal, Amar; Agarwal, Athiya; A I, Saijimol

    2017-08-01

    To assess an air pump-assisted technique for graft centration, graft edge unfolding, and graft uncreasing while performing pre-Descemet endothelial keratoplasty (PDEK) using young donor grafts. Continuous pressurized air infusion was used for graft centration, graft edge unfolding, and graft unwrinkling. Ten eyes of 10 patients underwent PDEK with donors aged below 40 years. In all eyes, the donor scrolled into tight scrolls. In all cases, the air pump-assisted technique was effective in positioning and centering the graft accurately and in straightening infolded graft edges and smoothing out graft creases and wrinkles. Endothelial cell loss was 38.6%. Postoperative best-corrected visual acuity at 6 months was 0.66 ± 0.25 in decimal equivalent. Continuous pressurized air infusion acted as a third hand providing a continuous pressure head that supported the graft and prevented graft dislocation as well as anterior chamber collapse during intraocular maneuvering. Adequate maneuvering space was available in all cases, and bleeding, if any, was tamponaded successfully in all cases. Although very young donor grafts may be used for PDEK, they are difficult to center and unroll completely before floating against host stroma. An air pump-assisted technique using continuous pressurized air infusion allows successful final graft positioning even with very young donor corneas. It thus makes surgery easier as several key steps are made easier to handle. It additionally helps in tamponading hemorrhage during peripheral iridectomy, increasing surgical space, preventing fluctuations in the anterior chamber depth, and promoting graft adherence.

  19. FAS grafted superhydrophobic ceramic membrane

    Energy Technology Data Exchange (ETDEWEB)

    Lu Jun [School of Material Science and Engineering, Jingdezhen Ceramic Institute, 333001 Jingdezhen (China); Key Laboratory of Inorganic Coating Materials, Shanghai Institute of Ceramics, CAS, 1295 DingXi Road, Shanghai 200050 (China); Yu Yun, E-mail: yunyush@mail.sic.ac.cn [Key Laboratory of Inorganic Coating Materials, Shanghai Institute of Ceramics, CAS, 1295 DingXi Road, Shanghai 200050 (China); Zhou Jianer [School of Material Science and Engineering, Jingdezhen Ceramic Institute, 333001 Jingdezhen (China); Song Lixin; Hu Xingfang [Key Laboratory of Inorganic Coating Materials, Shanghai Institute of Ceramics, CAS, 1295 DingXi Road, Shanghai 200050 (China); Larbot, Andre [Institut Europeen des Membranes, UMR 5635-CNRS, ENSCM, UMII, 1919 Route de Mende 34293, Montpellier Cedex 5 (France)

    2009-08-30

    The hydrophobic properties of {gamma}-Al{sub 2}O{sub 3} membrane have been obtained by grafting fluoroalkylsilane (FAS) on the surface of the membrane. The following grafting parameters were studied: the eroding time of the original membrane, the grafting time, the concentration of FAS solution and the multiplicity of grafting. Hydrophobicity of the membranes was characterized by contact angle (CA) measurement. The thermogravimetric analysis (TGA) was used to investigate the weight loss process (25-800 deg. C) of the fluoroalkylsilane grafted on Al{sub 2}O{sub 3} powders under different grafting conditions. The morphologies of the membranes modified under different parameters were examined by field emission scanning electron microscopy (FE-SEM) and the surface roughness (Ra) was measured using white light interferometers. A needle-like structure was observed on the membrane surface after modification, which causes the change of Ra. On the results above, we speculated a model to describe the reaction between FAS and {gamma}-Al{sub 2}O{sub 3} membrane surface as well as the formed surface morphology.

  20. FAS grafted superhydrophobic ceramic membrane

    Science.gov (United States)

    Lu, Jun; Yu, Yun; Zhou, Jianer; Song, Lixin; Hu, Xingfang; Larbot, Andre

    2009-08-01

    The hydrophobic properties of γ-Al 2O 3 membrane have been obtained by grafting fluoroalkylsilane (FAS) on the surface of the membrane. The following grafting parameters were studied: the eroding time of the original membrane, the grafting time, the concentration of FAS solution and the multiplicity of grafting. Hydrophobicity of the membranes was characterized by contact angle (CA) measurement. The thermogravimetric analysis (TGA) was used to investigate the weight loss process (25-800 °C) of the fluoroalkylsilane grafted on Al 2O 3 powders under different grafting conditions. The morphologies of the membranes modified under different parameters were examined by field emission scanning electron microscopy (FE-SEM) and the surface roughness (Ra) was measured using white light interferometers. A needle-like structure was observed on the membrane surface after modification, which causes the change of Ra. On the results above, we speculated a model to describe the reaction between FAS and γ-Al 2O 3 membrane surface as well as the formed surface morphology.

  1. Interventions in Infrainguinal Bypass Grafts

    International Nuclear Information System (INIS)

    Mueller-Huelsbeck, S.; Order, B.-M.; Jahnke, T.

    2006-01-01

    The interventional radiologist plays an important role in the detection and prevention of infrainguinal bypass failure. Early detection and evaluation of flow-limiting lesions effectively preserve graft (venous bypass and polyester or expanded polytetrafluoroethylene bypass) patency by identifying stenoses before occlusion occurs. Delay in treatment of the at-risk graft may result in graft failure and a reduced chance of successful revascularization. For this reason, surveillance protocols form an important part of follow-up after infrainguinal bypass surgery. As well as having an understanding of the application of imaging techniques including ultrasound, MR angiography, CT angiography and digital subtraction angiography, the interventional radiologist should have detailed knowledge of the minimally invasive therapeutic options. Percutaneous transluminal angioplasty (PTA), or alternatively cutting balloon angioplasty, is the interventional treatment of choice in prevention of graft failure and occlusion. Further alternatives include metallic stent placement, fibrinolysis, and mechanical thrombectomy. Primary assisted patency rates following PTA can be up to 65% at 5 years. When the endovascular approach is unsuccessful, these therapeutic options are complemented by surgical procedures including vein patch revision, jump grafting, or placement of a new graft

  2. Comparative study of navigated versus freehand osteochondral graft transplantation of the knee.

    Science.gov (United States)

    Koulalis, Dimitrios; Di Benedetto, Paolo; Citak, Mustafa; O'Loughlin, Padhraig; Pearle, Andrew D; Kendoff, Daniel O

    2009-04-01

    Osteochondral lesions are a common sports-related injury for which osteochondral grafting, including mosaicplasty, is an established treatment. Computer navigation has been gaining popularity in orthopaedic surgery to improve accuracy and precision. Navigation improves angle and depth matching during harvest and placement of osteochondral grafts compared with conventional freehand open technique. Controlled laboratory study. Three cadaveric knees were used. Reference markers were attached to the femur, tibia, and donor/recipient site guides. Fifteen osteochondral grafts were harvested and inserted into recipient sites with computer navigation, and 15 similar grafts were inserted freehand. The angles of graft removal and placement as well as surface congruity (graft depth) were calculated for each surgical group. The mean harvesting angle at the donor site using navigation was 4 degrees (standard deviation, 2.3 degrees ; range, 1 degrees -9 degrees ) versus 12 degrees (standard deviation, 5.5 degrees ; range, 5 degrees -24 degrees ) using freehand technique (P standard deviation, 2.1 degrees ; range, 0 degrees -9 degrees ) versus 10.7 degrees (standard deviation, 4.9 degrees ; range, 2 degrees -17 degrees ) in freehand (P standard deviation, 2.0 degrees ; range, 1 degrees -9 degrees ) versus 10.6 degrees (standard deviation, 4.4 degrees ; range, 3 degrees -17 degrees ) with freehand technique (P = .0001). The mean height of plug protrusion under navigation was 0.3 mm (standard deviation, 0.2 mm; range, 0-0.6 mm) versus 0.5 mm (standard deviation, 0.3 mm; range, 0.2-1.1 mm) using a freehand technique (P = .0034). Significantly greater accuracy and precision were observed in harvesting and placement of the osteochondral grafts in the navigated procedures. Clinical studies are needed to establish a benefit in vivo. Improvement in the osteochondral harvest and placement is desirable to optimize clinical outcomes. Navigation shows great potential to improve both harvest

  3. A Case of Successful Simultaneous Pancreas-Kidney Transplantation Using the Injured Pancreas Graft.

    Science.gov (United States)

    Miyagi, S; Shimizu, K; Miyazawa, K; Nakanishi, W; Hara, Y; Tokodai, K; Nakanishi, C; Satomi, S; Goto, M; Unno, M; Kamei, T

    2017-12-01

    Graft injuries sometimes occur and may cause complications such as the leakage of pancreatic secretions, which is often lethal. We report our experience of a case of successful simultaneous pancreas-kidney transplantation using injured pancreas graft. The recipient was a 57-year-old woman with type 1 diabetes mellitus, and the donor was a 30-year-old man with a brain injury. In the donation, the pancreas parenchyma, splenic artery, and gastroduodenal artery were injured iatrogenically. We therefore reconstructed these arteries using vessel grafts and then performed simultaneous pancreas-kidney transplantation. Five days after transplantation, we noted a high titer of amylase in the ascites; therefore, we performed an urgent laparotomy. The origin of the amylase was the injured pancreatic parenchyma, and continued washing and drainage were carried out. We reconstructed the duodenojejunostomy using the Roux-en-Y technique to separate the passage of food from the pancreas graft to prevent injury to other organs due to exposure to pancreatic secretions. Thereafter, we inserted a decompression tube into the anastomosis thorough the blind end of the jejunum. Finally, we inserted 3 drainage tubes for lavage. Following this procedure, the patient recovered gradually and no longer required hemodialysis and insulin therapy. She was discharged from our hospital 56 days after transplantation. The restoration of the injured graft was possible by management of pancreatic secretions and use of the donor's vessel grafts. Shortage of donors is a problem throughout the world; thus, it is important to use injured grafts for transplantation if possible. Copyright © 2017 Elsevier Inc. All rights reserved.

  4. A Comparative study of early postpartum IUCD insertion to interval IUCD insertion at Tertiary Care Centre

    OpenAIRE

    Roopal, Dr.; Bisht, Vandana

    2018-01-01

    Background: A Comparative study of early postpartum IUCD insertion to interval IUCD insertion at Tertiary Care Centre.Methods: This prospective study was conducted among 100 women at tertiary care centre, Haldwani, Nainital. Patients were divided in to two groups. Group A (n=50)-post placental insertion within 10 minutes of delivery of placenta. Group B (n=50)-Interval insertion after 6 weeks of delivery. Both groups were compared in terms of pain abdomen, bleeding, missing thread, expulsion,...

  5. Role of honey in modern medicine

    Directory of Open Access Journals (Sweden)

    Sultan Ayoub Meo

    2017-07-01

    Full Text Available Use of honey has a very long history. Honey has been used since ancient time due to its nutritional and therapeutic values. There had been varied ways of consumption honey including its use as a sweetener and flavoring agent. Honey is produced all over the world. The most important nutriment of honey is carbohydrates present in the form of monosaccharides, fructose and glucose. Honey plays an important role as an antioxidant, anti-inflammatory, anti-bacterial agent and augments the adherence of skin grafts and wound healing process. The role of honey has been acknowledged in the scientific literature and there is convincing evidence in support of its antioxidant and antibacterial nature, cough prevention, fertility and wound healing properties. However, its use has been controversially discussed and has not been well accepted in the modern medicine. The aim of this review was explore and highlight the role of honey in modern medicine.

  6. Radiation grafting on natural films

    International Nuclear Information System (INIS)

    Lacroix, M.; Khan, R.; Senna, M.; Sharmin, N.; Salmieri, S.; Safrany, A.

    2014-01-01

    Different methods of polymer grafting using gamma irradiation are reported in the present study for the preparation of newly functionalized biodegradable films, and some important properties related to their mechanical and barrier properties are described. Biodegradable films composed of zein and poly(vinyl alcohol) (PVA) were gamma-irradiated in presence of different ratios of acrylic acid (AAc) monomer for compatibilization purpose. Resulting grafted films (zein/PVA-g-AAc) had their puncture strength (PS=37–40 N mm −1 ) and puncture deformation (PD=6.5–9.8 mm) improved for 30% and 50% PVA in blend, with 5% AAc under 20 kGy. Methylcellulose (MC)-based films were irradiated in the presence of 2-hydroxyethyl methacrylate (HEMA) or silane, in order to determine the effect of monomer grafting on the mechanical properties of films. It was found that grafted films (MC-g-HEMA and MC-g-silane) using 35% monomer performed higher mechanical properties with PS values of 282–296 N mm −1 and PD of 5.0–5.5 mm under 10 kGy. Compatibilized polycaprolactone (PCL)/chitosan composites were developed via grafting silane in chitosan films. Resulting trilayer grafted composite film (PCL/chitosan-g-silane/PCL) presented superior tensile strength (TS=22 MPa) via possible improvement of interfacial adhesion (PCL/chitosan) when using 25% silane under 10 kGy. Finally, MC-based films containing crystalline nanocellulose (CNC) as a filling agent were prepared and irradiated in presence of trimethylolpropane trimethacrylate (TMPTMA) as a grafted plasticizer. Grafted films (MC-g-TMPTMA) presented superior mechanical properties with a TS of 47.9 MPa and a tensile modulus (TM) of 1792 MPa, possibly due to high yield formation of radicals to promote TMPTMA grafting during irradiation. The addition of CNC led to an additional improvement of the barrier properties, with a significant 25% reduction of water vapor permeability (WVP) of grafted films. - Highlights: • Irradiation of zein

  7. Versatility of the ventral approach in bulbar urethroplasty using dorsal, ventral or dorsal plus ventral oral grafts.

    Science.gov (United States)

    Palminteri, Enzo; Berdondini, Elisa; Fusco, Ferdinando; De Nunzio, Cosimo; Giannitsas, Kostas; Shokeir, Ahmed A

    2012-06-01

    To investigate the versatility of the ventral urethrotomy approach in bulbar reconstruction with buccal mucosa (BM) grafts placed on the dorsal, ventral or dorsal plus ventral urethral surface. Between 1999 and 2008, 216 patients with bulbar strictures underwent BM graft urethroplasty using the ventral-sagittal urethrotomy approach. Of these patients, 32 (14.8%; mean stricture 3.2 cm, range 1.5-5) had a dorsal graft urethroplasty (DGU), 121 (56%; mean stricture 3.7, range 1.5-8) a ventral graft urethroplasty (VGU), and 63 (29.2%; mean stricture 3.4, range 1.5-10) a dorsal plus ventral graft urethroplasty (DVGU). The strictured urethra was opened by a ventral-sagittal urethrotomy and BM graft was inserted dorsally or ventrally or dorsal plus ventral to augment the urethral plate. The median follow-up was 37 months. The overall 5-year actuarial success rate was 91.4%. The 5-year actuarial success rates were 87.8%, 95.5% and 86.3% for the DGU, VGU and DVGU, respectively. There were no statistically significant differences among the three groups. Success rates decreased significantly only with a stricture length of >4 cm. In BM graft bulbar urethroplasties the ventral urethrotomy access is simple and versatile, allowing an intraoperative choice of dorsal, ventral or combined dorsal and ventral grafting, with comparable success rates.

  8. Central Solenoid Insert Technical Specification

    Energy Technology Data Exchange (ETDEWEB)

    Martovetsky, Nicolai N [ORNL; Smirnov, Alexandre [ORNL

    2011-09-01

    The US ITER Project Office (USIPO) is responsible for the ITER central solenoid (CS) contribution to the ITER project. The Central Solenoid Insert (CSI) project will allow ITER validation the appropriate lengths of the conductors to be used in the full-scale CS coils under relevant conditions. The ITER Program plans to build and test a CSI to verify the performance of the CS conductor. The CSI is a one-layer solenoid with an inner diameter of 1.48 m and a height of 4.45 m between electric terminal ends. The coil weight with the terminals is approximately 820 kg without insulation. The major goal of the CSI is to measure the temperature margin of the CS under the ITER direct current (DC) operating conditions, including determining sensitivity to load cycles. Performance of the joints, ramp rate sensitivity, and stability against thermal or electromagnetic disturbances, electrical insulation, losses, and instrumentation are addressed separately and therefore are not major goals in this project. However, losses and joint performance will be tested during the CSI testing campaign. The USIPO will build the CSI that will be tested at the Central Solenoid Model Coil (CSMC) Test Facility at the Japan Atomic Energy Agency (JAEA), Naka, Japan. The industrial vendors (the Suppliers) will report to the USIPO (the Company). All approvals to proceed will be issued by the Company, which in some cases, as specified in this document, will also require the approval of the ITER Organization. Responsibilities and obligations will be covered by respective contracts between the USIPO, called Company interchangeably, and the industrial Prime Contractors, called Suppliers. Different stages of work may be performed by more than one Prime Contractor, as described in this specification. Technical requirements of the contract between the Company and the Prime Contractor will be covered by the Fabrication Specifications developed by the Prime Contractor based on this document and approved by

  9. H-Y Antigen Incompatibility Not Associated with Adverse Immunologic Graft Outcomes: Deceased Donor Pair Analysis of the OPTN Database

    Directory of Open Access Journals (Sweden)

    Douglas Scott Keith

    2011-01-01

    Full Text Available Background. H-Y antigen incompatibility adversely impacts bone marrow transplants however, the relevance of these antigens in kidney transplantation is uncertain. Three previous retrospective studies of kidney transplant databases have produced conflicting results. Methods. This study analyzed the Organ Procurement and Transplantation Network database between 1997 and 2009 using male deceased donor kidney transplant pairs in which the recipient genders were discordant. Death censored graft survival at six months, five, and ten years, treated acute rejection at six months and one year, and rates of graft failure by cause were the primary endpoints analyzed. Results. Death censored graft survival at six months was significantly worse for female recipients. Analysis of the causes of graft failure at six months revealed that the difference in death censored graft survival was due primarily to nonimmunologic graft failures. The adjusted and unadjusted death censored graft survivals at five and ten years were similar between the two genders as were the rates of immunologic graft failure. No difference in the rates of treated acute rejection at six months and one year was seen between the two genders. Conclusions. Male donor to female recipient discordance had no discernable effect on immunologically mediated kidney graft outcomes in the era of modern immunosuppression.

  10. Gamma irradiation effects on the grafting of low-density polyethylene with diethyl maleate

    International Nuclear Information System (INIS)

    Sanchez, Y.; Albano, C.; Karam, A.; Perera, R.; Silva, P.; Gonzalez, J.

    2005-01-01

    In this work, a low-density polyethylene (LDPE) was grafted with diethyl maleate (DEM) using gamma-rays from a Cobalt-60 source at different absorbed doses and monomer concentrations between 5 and 30 wt.%. This process was carried out in a decalin solution at 10 w/v% to obtain a homogeneous dispersion of the monomer into the polyethylene matrix. It was found that the grafting degree increases with the absorbed doses, as a consequence of the increased amount of energy given to the system, which made the grafting process more favorable. The grafting degree also increases with the concentration of DEM, because a higher concentration makes the insertion easier due to the increased availability of the free monomer. The highest grafting degree was obtained at 200 kGy of absorbed dose and with 30 wt.% of DEM. The melt flow index (MFI) values showed a decreasing trend as the absorbed dose was increased. This fact reveals that crosslinking and grafting are taking place simultaneously, this behavior being remarkable at higher irradiation doses. The results from thermogravimetric analysis (TGA) showed that the initial degradation temperatures remained almost unchanged with the absorbed dose

  11. MR imaging of avascular scaphoid nonunion before and after vascularized bone grafting

    Energy Technology Data Exchange (ETDEWEB)

    Anderson, Suzanne E.; Tschering-Vogel, Dechen; Martin, Matthias [University Hospital of Bern, Inselspital, Department of Radiology, Bern (Switzerland); Steinbach, Lynne S. [University of California San Francisco, Department of Radiology, San Francisco, California (United States); Nagy, Ladislav [University Hospital of Bern, Inselspital, Department of Orthopedic Surgery, Bern (Switzerland)

    2005-06-01

    To investigate the magnetic resonance (MR) imaging appearances of chronic nonunion of the scaphoid with proximal pole avascular necrosis before and after insertion of a vascularized bone graft, using computed tomography (CT) as the imaging gold standard. A retrospective study was performed involving MR imaging (n=26), CT scans (n=37) and radiographs (n=52) of 13 men (mean age 29 years, age range 20-38 years) with avascular scaphoid nonunion. Avascular necrosis of the scaphoid proximal pole was confirmed intraoperatively (n=13). MR images were acquired preoperatively and following placement of a vascularized bone graft. Scaphoid MR signal characteristics were assessed for evidence of vascular bone graft incorporation and revascularization of the bone marrow of the proximal pole of the scaphoid and compared with the gold standard of CT. Surgical and clinical notes were reviewed with a minimum 3 year imaging and clinical follow-up in all patients. Graft incorporation with revascularization of the proximal pole of the scaphoid was documented in 9 patients (69%). Graft failure with persistent pseudoarthrosis and avascular necrosis of the scaphoid was seen in 4 patients (31%). MR imaging is useful to determine whether vascularized bone graft incorporation and revascularization of the proximal pole of the scaphoid has occurred in the setting of avascular scaphoid nonunion. (orig.)

  12. MR imaging of avascular scaphoid nonunion before and after vascularized bone grafting

    International Nuclear Information System (INIS)

    Anderson, Suzanne E.; Tschering-Vogel, Dechen; Martin, Matthias; Steinbach, Lynne S.; Nagy, Ladislav

    2005-01-01

    To investigate the magnetic resonance (MR) imaging appearances of chronic nonunion of the scaphoid with proximal pole avascular necrosis before and after insertion of a vascularized bone graft, using computed tomography (CT) as the imaging gold standard. A retrospective study was performed involving MR imaging (n=26), CT scans (n=37) and radiographs (n=52) of 13 men (mean age 29 years, age range 20-38 years) with avascular scaphoid nonunion. Avascular necrosis of the scaphoid proximal pole was confirmed intraoperatively (n=13). MR images were acquired preoperatively and following placement of a vascularized bone graft. Scaphoid MR signal characteristics were assessed for evidence of vascular bone graft incorporation and revascularization of the bone marrow of the proximal pole of the scaphoid and compared with the gold standard of CT. Surgical and clinical notes were reviewed with a minimum 3 year imaging and clinical follow-up in all patients. Graft incorporation with revascularization of the proximal pole of the scaphoid was documented in 9 patients (69%). Graft failure with persistent pseudoarthrosis and avascular necrosis of the scaphoid was seen in 4 patients (31%). MR imaging is useful to determine whether vascularized bone graft incorporation and revascularization of the proximal pole of the scaphoid has occurred in the setting of avascular scaphoid nonunion. (orig.)

  13. Kinetics of vein graft hyperplasia

    International Nuclear Information System (INIS)

    Zwolak, R.M.; Adams, M.C.; Clowes, A.W.

    1986-01-01

    Human aortocoronary vein grafts fail due to accelerated occlusive disease. The possibility that this is related to cellular hyperplasia was investigated in a rabbit model where kinetics of vein graft thickening, endothelial (EC) repair, and smooth muscle cell (SMC) proliferation were measured from 2 days to 24 weeks after implanting jugular vein segments in the carotid artery. Immediately after graft placement focal EC denudation was observed. These defects were repaired within 1 week and did not recur. By 4 weeks intimal area had increased 30 fold from 0.028 +/- 0.004 to 0.705 +/- 0.021 mm 2 , and a 24 weeks was 0.93 +/- 0.21 mm 2 . This response did not produce a reduction in graft lumen area. EC and SMC thymidine-labeling index were measured by en face and cross-section autoradiography after injection of 3 H-thymidine and perfusion fixation. Despite rapid EC surface repair EC labeling index remained elevated and only returned to normal levels at 12 weeks; SMC labeling was 10 fold greater than baseline even at 24 weeks (0.22% vs 0.02%). SMC mass demonstrated morphometrically increased between 2 and 12 weeks. Intimal thickening in vein grafts is due to SMC proliferation and develops after the EC layer has been restored. In contrast, intimal SMC proliferate in damaged arteries when the EC layer is absent and cease when the EC layer is regenerated

  14. Insertion profiles of 4 headless compression screws.

    Science.gov (United States)

    Hart, Adam; Harvey, Edward J; Lefebvre, Louis-Philippe; Barthelat, Francois; Rabiei, Reza; Martineau, Paul A

    2013-09-01

    In practice, the surgeon must rely on screw position (insertion depth) and tactile feedback from the screwdriver (insertion torque) to gauge compression. In this study, we identified the relationship between interfragmentary compression and these 2 factors. The Acutrak Standard, Acutrak Mini, Synthes 3.0, and Herbert-Whipple implants were tested using a polyurethane foam scaphoid model. A specialized testing jig simultaneously measured compression force, insertion torque, and insertion depth at half-screw-turn intervals until failure occurred. The peak compression occurs at an insertion depth of -3.1 mm, -2.8 mm, 0.9 mm, and 1.5 mm for the Acutrak Mini, Acutrak Standard, Herbert-Whipple, and Synthes screws respectively (insertion depth is positive when the screw is proud above the bone and negative when buried). The compression and insertion torque at a depth of -2 mm were found to be 113 ± 18 N and 0.348 ± 0.052 Nm for the Acutrak Standard, 104 ± 15 N and 0.175 ± 0.008 Nm for the Acutrak Mini, 78 ± 9 N and 0.245 ± 0.006 Nm for the Herbert-Whipple, and 67 ± 2N, 0.233 ± 0.010 Nm for the Synthes headless compression screws. All 4 screws generated a sizable amount of compression (> 60 N) over a wide range of insertion depths. The compression at the commonly recommended insertion depth of -2 mm was not significantly different between screws; thus, implant selection should not be based on compression profile alone. Conically shaped screws (Acutrak) generated their peak compression when they were fully buried in the foam whereas the shanked screws (Synthes and Herbert-Whipple) reached peak compression before they were fully inserted. Because insertion torque correlated poorly with compression, surgeons should avoid using tactile judgment of torque as a proxy for compression. Knowledge of the insertion profile may improve our understanding of the implants, provide a better basis for comparing screws, and enable the surgeon to optimize compression. Copyright

  15. Laparoscopic insertion of the Moss feeding tube.

    Science.gov (United States)

    Albrink, M H; Hagan, K; Rosemurgy, A S

    1993-12-01

    Placement of enteral feeding tubes is an important part of a surgeon's skill base. Surgical insertion of feeding tubes has been performed safely for many years with very few modifications. With the recent surge in interest and applicability of other laparoscopic procedures, it is well within the skills of the average laparoscopic surgeon to insert feeding tubes. We describe herein a simple technique for the insertion of the Moss feeding tube. The procedure described has a minimum of invasion, along with simplicity, safety, and accuracy.

  16. Vascularized osseous graft for scaphoid

    International Nuclear Information System (INIS)

    Mendez Daza, Carlos Hernan; Mathoulin, Cristophe

    2004-01-01

    The most commonly used technique for treatment of pseudo-arthrosis of the scaphoid is osteo-synthesis with Kirschnet wires and cortical sponge grafts. Results reported by different teams using this procedure show no more than 90% osseous consolidation, especially in cases where vascularisation of the proximal fragment of the scaphoid is compromised. Here we present a series of ten cases of pseudo-arthrosis of the scaphoid, treated using a new surgical technique involving a vascularized osseous graft of the distal radius. Using this procedure we obtained 100% consolidation, with no complications either during the procedure or immediately post-operatively. Patients returned to work in week 15 on average. In 4 cases we observed discomfort in the area of the scar, which was successfully treated using local cortisone injection. The results obtained are very similar to those seen in the literature on the different techniques for vascularized osseous grafts for pseudo-arthrosis of the scaphoid

  17. Insertable fluid flow passage bridgepiece and method

    Science.gov (United States)

    Jones, Daniel O.

    2000-01-01

    A fluid flow passage bridgepiece for insertion into an open-face fluid flow channel of a fluid flow plate is provided. The bridgepiece provides a sealed passage from a columnar fluid flow manifold to the flow channel, thereby preventing undesirable leakage into and out of the columnar fluid flow manifold. When deployed in the various fluid flow plates that are used in a Proton Exchange Membrane (PEM) fuel cell, bridgepieces of this invention prevent mixing of reactant gases, leakage of coolant or humidification water, and occlusion of the fluid flow channel by gasket material. The invention also provides a fluid flow plate assembly including an insertable bridgepiece, a fluid flow plate adapted for use with an insertable bridgepiece, and a method of manufacturing a fluid flow plate with an insertable fluid flow passage bridgepiece.

  18. Utility Bill Insert for Wastewater Services

    Science.gov (United States)

    Intended for use by wastewater and water supply utilities, one side of the utility bill insert has information for customers that discharge to sanitary sewer systems; the other side is for customers with septic systems.

  19. HB+ inserted into the CMS Solenoid

    CERN Multimedia

    Tejinder S. Virdee, CERN

    2006-01-01

    The first half of the barrel hadron calorimeter (HB+) has been inserted into the superconducting solenoid of CMS, in preparation for the magnet test and cosmic challenge. The operation went smoothly, lasting a couple of days.

  20. Bulkhead insert for an internal combustion engine

    Science.gov (United States)

    Maki, Clifford E.; Chottiner, Jeffrey Eliot; Williams, Rick L.; Thibault, Mark W.; Ervin, James Douglas; Boileau, James Maurice; McKeough, Bryan

    2017-08-01

    An engine includes a cylinder block defining at least one main bearing bulkhead adjacent to a cylinder, and a crankshaft rotatably housed within the block by a main bearing. A bulkhead insert has a cap portion, and an insert portion provided within the bulkhead. The insert portion has having first and second end regions connected by first and second straps. Each strap having a flanged beam cross section. The first and second ends of the insert portion are configured to connect a main bearing cap column to a cylinder head column. Each of the first and second end regions define at least one protrusion having a surface substantially normal to engine combustion and reactive loads. The cap portion is configured to mate with the first end region at the main bearing cap column and support the main bearing.

  1. Breaking the regioselectivity rule for acrylate insertion in the Mizoroki-Heck reaction.

    Science.gov (United States)

    Wucher, Philipp; Caporaso, Lucia; Roesle, Philipp; Ragone, Francesco; Cavallo, Luigi; Mecking, Stefan; Göttker-Schnetmann, Inigo

    2011-05-31

    In modern methods for the preparation of small molecules and polymers, the insertion of substrate carbon-carbon double bonds into metal-carbon bonds is a fundamental step of paramount importance. This issue is illustrated by Mizoroki-Heck coupling as the most prominent example in organic synthesis and also by catalytic insertion polymerization. For unsymmetric substrates H(2)C = CHX the regioselectivity of insertion is decisive for the nature of the product formed. Electron-deficient olefins insert selectively in a 2,1-fashion for electronic reasons. A means for controlling this regioselectivity is lacking to date. In a combined experimental and theoretical study, we now report that, by destabilizing the transition state of 2,1-insertion via steric interactions, the regioselectivity of methyl acrylate insertion into palladium-methyl and phenyl bonds can be inverted entirely to yield the opposite "regioirregular" products in stoichiometric reactions. Insights from these experiments will aid the rational design of complexes which enable a catalytic and regioirregular Mizoroki-Heck reaction of electron-deficient olefins.

  2. Grafted SiC nanocrystals

    DEFF Research Database (Denmark)

    Saini, Isha; Sharma, Annu; Dhiman, Rajnish

    2017-01-01

    ), raman spectroscopy and X-ray diffraction (XRD) measurements. UV–Visible absorption spectroscopy was used to study optical properties such as optical energy gap (Eg), Urbach's energy (Eu), refractive index (n), real (ε1) and imaginary (ε2) parts of dielectric constant of PVA as well as PVA......Polyvinyl alcohol (PVA) grafted SiC (PVA-g-SiC)/PVA nanocomposite was synthesized by incorporating PVA grafted silicon carbide (SiC) nanocrystals inside PVA matrix. In-depth structural characterization of resulting nanocomposite was carried out using fourier transform infrared spectroscopy (FTIR...

  3. Chronic insertional Achilles tendinopathy: surgical outcomes

    OpenAIRE

    Oshri, Yael; Palmanovich, Ezequiel; Brin, Yaron Shagra; Karpf, Ronen; Massarwe, Sabri; Kish, Benny; Nyska, Meir

    2012-01-01

    Background and objective: insertional Achilles tendinopathy is a common condition among athletes and joggers. One fifth of the injuries involves the insertion of the tendon. The etiology is either due to mechanical overuse related to sports activity, or a systemic inflammatory disease. The clinical appearance includes pain and movement restriction. The primary treatment is conservative. The surgery referred to in this study (Calcaneal Osteotomy) is performed by decompression of the posterior ...

  4. Oral mucosa grafts for urethral reconstruction

    African Journals Online (AJOL)

    reports reveal that split and full thickness skin grafts from the scrotum, penis, extragenital sites (ureter, saphenous .... Table 1: Summary of the history of oral mucosa grafts for urethroplasty .... advised that care should be taken when suturing the.

  5. Er Rousseau moderne?

    DEFF Research Database (Denmark)

    Dupont, Søren

    1985-01-01

    Artiklen analyserer på hvilken måde Rousseau kan siges at være moderne, og den diskuterer på hvilken måde Rouseau har været medvirkende til at opbygge den moderne civilisation, og på hvilken måde han var kritisk i forhold til den gryende og moderne kapitalisme.......Artiklen analyserer på hvilken måde Rousseau kan siges at være moderne, og den diskuterer på hvilken måde Rouseau har været medvirkende til at opbygge den moderne civilisation, og på hvilken måde han var kritisk i forhold til den gryende og moderne kapitalisme....

  6. Late-Modern Symbolism

    DEFF Research Database (Denmark)

    Andersen, Bjørn Schiermer

    2015-01-01

    Through analysis of key texts, I seek to demonstrate the explanative potential of Durkheim’s sociology of religion in the present context. I critically readdress the idea, found in his early work, that modernity is characterized by a rupture with pre-modern forms of solidarity. First, I investigate...... the ways in which Durkheim sets up a stark distinction between the pre-modern and the modern in his early work, and how this distinction is further cemented by his orthodox critique of the modern economy and its negative effects on social life. Second, I show how another timeless and positive understanding...... of “mechanical” solidarity is to be found behind the “symbolist” template crystalizing in Durkheim’s late work. Third, I develop this template for a modern context by critically addressing and removing other obstacles and prejudices on Durkheim’s part....

  7. Cephalic Arch Stenosis in Autogenous Haemodialysis Fistulas: Treatment With the Viabahn Stent-Graft

    Energy Technology Data Exchange (ETDEWEB)

    Shawyer, Andrew, E-mail: andrew.shawyer@bartsandthelondon.nhs.uk [The Royal London Hospital, Radiology Department (United Kingdom); Fotiadis, Nicos I., E-mail: fotiadis.nicholas@gmail.com [Royal Marsden Hospital, Radiology Department, The Royal Marsden NHS Foundation Trust (United Kingdom); Namagondlu, Girish, E-mail: girish.namagondlu@bartsandthelondon.nhs.uk [The Royal London Hospital, Renal Medicine Department (United Kingdom); Iyer, Arun, E-mail: arun.iyer@bartsandthelondon.nhs.uk [The Royal London Hospital, Radiology Department (United Kingdom); Blunden, Mark, E-mail: mark.blunden@bartsandthelondon.nhs.uk; Raftery, Martin, E-mail: martin.raftery@bartsandthelondon.nhs.uk; Yaqoob, Magdi, E-mail: magdi.yaqoob@bartsandthelondon.nhs.uk [The Royal London Hospital, Renal Medicine Department (United Kingdom)

    2013-02-15

    Cephalic arch stenosis (CAS) is an important and common cause of dysfunction in autogenous haemodialysis fistulas that requires multiple reinterventions and aggressive surveillance. We evaluated the safety and efficacy of the Viabahn stent-graft for the management of CAS. Between April 2005 and October 2011, 11 consecutive patients [four men and seven women (mean age 56.7 years)] with CAS and dysfunctional fistulas were treated with insertion of 11 Viabahn stent-grafts. Six stent-grafts were inserted due to residual stenosis after angioplasty and five for fistuloplasty-induced rupture. No patient was lost to follow-up. The technical and clinical success rate was 100 %. Primary access patency rates were 81.8 % [95 % confidence interval (CI) 0.482-0.977] at 6 months and 72.7 % (95 % CI 0.390-0.939) at 12 months. Secondary access patency rates were 90.9 % at 6 months (95 % CI 0.587-0.997). There were no procedure-related complications. Mean follow-up was 543.8 days (range 156-2,282). The use of the Viabahn stent-graft in the management of CAS is technically feasible and, in this small series, showed patency rates that compare favorably with historical data of angioplasty and bare stents.

  8. Cephalic Arch Stenosis in Autogenous Haemodialysis Fistulas: Treatment With the Viabahn Stent-Graft

    International Nuclear Information System (INIS)

    Shawyer, Andrew; Fotiadis, Nicos I.; Namagondlu, Girish; Iyer, Arun; Blunden, Mark; Raftery, Martin; Yaqoob, Magdi

    2013-01-01

    Cephalic arch stenosis (CAS) is an important and common cause of dysfunction in autogenous haemodialysis fistulas that requires multiple reinterventions and aggressive surveillance. We evaluated the safety and efficacy of the Viabahn stent-graft for the management of CAS. Between April 2005 and October 2011, 11 consecutive patients [four men and seven women (mean age 56.7 years)] with CAS and dysfunctional fistulas were treated with insertion of 11 Viabahn stent-grafts. Six stent-grafts were inserted due to residual stenosis after angioplasty and five for fistuloplasty-induced rupture. No patient was lost to follow-up. The technical and clinical success rate was 100 %. Primary access patency rates were 81.8 % [95 % confidence interval (CI) 0.482–0.977] at 6 months and 72.7 % (95 % CI 0.390–0.939) at 12 months. Secondary access patency rates were 90.9 % at 6 months (95 % CI 0.587–0.997). There were no procedure-related complications. Mean follow-up was 543.8 days (range 156–2,282). The use of the Viabahn stent-graft in the management of CAS is technically feasible and, in this small series, showed patency rates that compare favorably with historical data of angioplasty and bare stents.

  9. Z-2 Threaded Insert Design and Testing

    Science.gov (United States)

    Ross, Amy; Rhodes, Richard; Jones, Robert J.; Graziosi, David; Ferl, Jinny; Sweeny, Mitch; Scarborough, Stephen

    2016-01-01

    NASA's Z-2 prototype space suit contains several components fabricated from an advanced hybrid composite laminate consisting of IM10 carbon fiber and fiber glass. One requirement was to have removable, replaceable helicoil inserts to which other suit components would be fastened. An approach utilizing bonded in inserts with helicoils inside of them was implemented. During initial assembly, cracking sounds were heard followed by the lifting of one of the blind inserts out of its hole when the screws were torqued. A failure investigation was initiated to understand the mechanism of the failure. Ultimately, it was determined that the pre-tension caused by torqueing the fasteners is a much larger force than induced from the pressure loads of the suit which was not considered in the insert design. Bolt tension is determined by dividing the torque on the screw by a k value multiplied by the thread diameter of the bolt. The k value is a factor that accounts for friction in the system. A common value used for k for a non-lubricated screw is 0.2. The k value can go down by as much as 0.1 if the screw is lubricated which means for the same torque, a much larger tension could be placed on the bolt and insert. This paper summarizes the failure investigation that was performed to identify the root cause of the suit failure and details how the insert design was modified to resist a higher pull out tension.

  10. Prevention of primary vascular graft infection with silver-coated polyester graft in a porcine model

    DEFF Research Database (Denmark)

    Gao, H; Sandermann, J; Prag, J

    2010-01-01

    To evaluate the efficacy of a silver-coated vascular polyester graft in the prevention of graft infection after inoculation with Staphylococcus aureus in a porcine model.......To evaluate the efficacy of a silver-coated vascular polyester graft in the prevention of graft infection after inoculation with Staphylococcus aureus in a porcine model....

  11. Evaluation of Replacement Grafts and Punch Grafts in the Treatment of Vitiligo

    Directory of Open Access Journals (Sweden)

    Singh Ajit Kumar

    1980-01-01

    Full Text Available Thirtycasesof vitiligo eachwithminimum of two lesions undent replacement graft and multiple punch grafts in one lesion each. Complications observed at the recipient site like infection and raised nigosed surface were significantly more in replacement grafts. Hypopigmentation of the graft was significantly more when the disease was progressive.

  12. Indonesia - Procurement Modernization

    Data.gov (United States)

    Millennium Challenge Corporation — The evaluation seeks to establish evidence on the possible effects of an intervention designed to modernize public procurement: effects on cost savings, performance...

  13. Annals of Modern Education

    African Journals Online (AJOL)

    The Annals of Modern Education will be considered for publication publishes regular papers reporting ... Curriculum and Teaching, Students' Perspectives on Learning Environments, Environmental Education, ... AJOL African Journals Online.

  14. Nuclear weapons modernizations

    Energy Technology Data Exchange (ETDEWEB)

    Kristensen, Hans M. [Federation of American Scientists, Washington, DC (United States)

    2014-05-09

    This article reviews the nuclear weapons modernization programs underway in the world's nine nuclear weapons states. It concludes that despite significant reductions in overall weapons inventories since the end of the Cold War, the pace of reductions is slowing - four of the nuclear weapons states are even increasing their arsenals, and all the nuclear weapons states are busy modernizing their remaining arsenals in what appears to be a dynamic and counterproductive nuclear competition. The author questions whether perpetual modernization combined with no specific plan for the elimination of nuclear weapons is consistent with the nuclear Non-Proliferation Treaty and concludes that new limits on nuclear modernizations are needed.

  15. Biology and augmentation of tendon-bone insertion repair

    Directory of Open Access Journals (Sweden)

    Lui PPY

    2010-08-01

    Full Text Available Abstract Surgical reattachment of tendon and bone such as in rotator cuff repair, patellar-patella tendon repair and anterior cruciate ligament (ACL reconstruction often fails due to the failure of regeneration of the specialized tissue ("enthesis" which connects tendon to bone. Tendon-to-bone healing taking place between inhomogenous tissues is a slow process compared to healing within homogenous tissue, such as tendon to tendon or bone to bone healing. Therefore special attention must be paid to augment tendon to bone insertion (TBI healing. Apart from surgical fixation, biological and biophysical interventions have been studied aiming at regeneration of TBI healing complex, especially the regeneration of interpositioned fibrocartilage and new bone at the healing junction. This paper described the biology and the factors influencing TBI healing using patella-patellar tendon (PPT healing and tendon graft to bone tunnel healing in ACL reconstruction as examples. Recent development in the improvement of TBI healing and directions for future studies were also reviewed and discussed.

  16. The influence of bone graft procedures on primary stability and bone change of implants placed in fresh extraction sockets.

    Science.gov (United States)

    Jun, Sang Ho; Park, Chang-Joo; Hwang, Suk-Hyun; Lee, Youn Ki; Zhou, Cong; Jang, Hyon-Seok; Ryu, Jae-Jun

    2018-12-01

    This study was to evaluate the effect of bone graft procedure on the primary stability of implants installed in fresh sockets and assess the vertical alteration of peri-implant bone radiographically. Twenty-three implants were inserted in 18 patients immediately after tooth extraction. The horizontal gap between the implant and bony walls of the extraction socket was grafted with xenografts. The implant stability before and after graft procedure was measured by Osstell Mentor as implant stability quotient before bone graft (ISQ bbg) and implant stability quotient after bone graft (ISQ abg). Peri-apical radiographs were taken to measure peri-implant bone change immediately after implant surgery and 12 months after implant placement. Data were analyzed by independent t test; the relationships between stability parameters (insertion torque value (ITV), ISQ abg, and ISQ bbg) and peri-implant bone changes were analyzed according to Pearson correlation coefficients. The increase of ISQ in low primary stability group (LPSG) was 6.87 ± 3.62, which was significantly higher than the increase in high primary stability group (HPSG). A significant correlation between ITV and ISQ bbg ( R  = 0.606, P  = 0.002) was found; however, age and peri-implant bone change were not found significantly related to implant stability parameters. It was presented that there were no significant peri-implant bone changes at 1 year after bone graft surgery. Bone graft procedure is beneficial for increasing the primary stability of immediately placed implants, especially when the ISQ of implants is below 65 and that bone grafts have some effects on peri-implant bone maintenance.

  17. Graft infections after surgical aortic reconstructions

    NARCIS (Netherlands)

    Berger, P.

    2015-01-01

    Prosthetic vascular grafts are frequently used to reconstruct (part) of the aorta. Every surgical procedure caries a certain risk for infection and when a prosthetic aortic graft is implanted, this may lead to an aortic graft infection (AGI). Endovascular techniques have gradually replaced open

  18. The caudal septum replacement graft.

    Science.gov (United States)

    Foda, Hossam M T

    2008-01-01

    To describe a technique for reconstructing the lost tip support in cases involving caudal septal and premaxillary deficiencies. The study included 120 patients with aesthetic and functional nasal problems resulting from the loss of caudal septal and premaxillary support. An external rhinoplasty approach was performed to reconstruct the lost support using a cartilaginous caudal septum replacement graft and premaxillary augmentation with Mersilene mesh. The majority of cases (75%) involved revisions in patients who had previously undergone 1 or more nasal surgical procedures. A caudal septum replacement graft was combined with premaxillary augmentation in 93 patients (77.5%). The mean follow-up period was 3 years (range, 1-12 years). The technique succeeded in correcting the external nasal deformities in all patients and resulted in a significant improvement in breathing in 74 patients (86%) with preoperative nasal obstruction. There were no cases of infection, displacement, or extrusion. The caudal septum replacement graft proved to be very effective in restoring the lost tip support in patients with caudal septal deficiency. Combining the graft with premaxillary augmentation using Mersilene mesh helped increase support and stability over long-term follow-up.

  19. ACL Graft Healing and Biologics

    NARCIS (Netherlands)

    Muller, Bart; Bowman, Karl F.; Bedi, Asheesh

    2013-01-01

    Operative reconstruction of a torn anterior cruciate ligament (ACL) has become the most broadly accepted treatment. An important, but underreported, outcome of ACL reconstruction is graft failure, which poses a challenge for the orthopedic surgeon. An understanding of the tendon-bone healing and the

  20. Polyether-polyester graft copolymer

    Science.gov (United States)

    Bell, Vernon L. (Inventor)

    1987-01-01

    Described is a polyether graft polymer having improved solvent resistance and crystalline thermally reversible crosslinks. The copolymer is prepared by a novel process of anionic copolymerization. These polymers exhibit good solvent resistance and are well suited for aircraft parts. Previous aromatic polyethers, also known as polyphenylene oxides, have certain deficiencies which detract from their usefulness. These commercial polymers are often soluble in common solvents including the halocarbon and aromatic hydrocarbon types of paint thinners and removers. This limitation prevents the use of these polyethers in structural articles requiring frequent painting. In addition, the most popular commercially available polyether is a very high melting plastic. This makes it considerably more difficult to fabricate finished parts from this material. These problems are solved by providing an aromatic polyether graft copolymer with improved solvent resistance and crystalline thermally reversible crosslinks. The graft copolymer is formed by converting the carboxyl groups of a carboxylated polyphenylene oxide polymer to ionic carbonyl groups in a suitable solvent, reacting pivalolactone with the dissolved polymer, and adding acid to the solution to produce the graft copolymer.

  1. Early tension loss in an anterior cruciate ligament graft. A cadaver study of four tibial fixation devices.

    Science.gov (United States)

    Grover, Dustin M; Howell, Stephen M; Hull, Maury L

    2005-02-01

    The tensile force applied to an anterior cruciate ligament graft determines the maximal anterior translation; however, it is unknown whether the tensile force is transferred to the intra-articular portion of the graft and whether the intra-articular tension and maximal anterior translation are maintained shortly after ligament reconstruction. Ten cadaveric knees were reconstructed with a double-looped tendon graft. The graft was looped through a femoral fixation transducer that measured the resultant force on the proximal end of the graft. A pneumatic cylinder applied a tensile force of 110 N to the graft exiting the tibial tunnel with the knee in full extension. The graft was fixed sequentially with four tibial fixation devices (a spiked metal washer, double staples, a bioabsorbable interference screw, and a WasherLoc). Three cyclic loading treatments designed to conservatively load the graft and its fixation were applied. The combined loss in intra-articular graft tension from friction, insertion of the tibial fixation device, and three cyclic loading treatments was 50% for the spiked washer (p = 0.0004), 100% for the double staples (p < 0.0001), 64% for the interference screw (p = 0.0001), and 56% for the WasherLoc (p < 0.0001). The tension loss caused an increase in the maximal anterior translation from that of the intact knee of 2.0 mm for the spiked washer (p = 0.005), 7.8 mm for the double staples (p < 0.0001), 2.7 mm for the interference screw (p = 0.001), and 2.1 mm for the WasherLoc (p < 0.0001). The tensile force applied to a soft-tissue anterior cruciate ligament graft is not transferred intra-articularly and is not maintained during graft fixation. The loss in tension is caused by friction in the tibial tunnel and wrapping the graft around the shank of the screw of the spiked washer, insertion of the tibial fixation device, and cyclical loading of the knee. The amount of tension loss is sufficient to increase the maximal anterior translation.

  2. Pleurotomy with subxyphoid pleural drain affords similar effects to pleural integrity in pulmonary function after off-pump coronary artery bypass graft

    OpenAIRE

    Guizilini, Solange; Bolzan, Douglas W; Faresin, Sonia M; Ferraz, Raquel F; Tavolaro, Kelly; Cancio, Andrea A; Gomes, Walter J

    2012-01-01

    Abstract Background Exacerbation of pulmonary dysfunction has been reported in patients receiving a pleural drain inserted through the intercostal space in comparison to patients with an intact pleura undergoing coronary artery bypass grafting (CABG). Evidence suggests that shifting the site of pleural drain insertion to the subxyphoid position minimizes chest wall trauma and preserves respiratory function in the early postoperative period. The aim of this study was to compare the pulmonary f...

  3. Modern examples of extinctions

    DEFF Research Database (Denmark)

    Lövei, Gabor L

    2013-01-01

    No species lives forever, and extinction is the ultimate fate of all living species. The fossil record indicates that a recent extinction wave affecting terrestrial vertebrates was parallel with the arrival of modern humans to areas formerly uninhabited by them. These modern instances of extinction...

  4. Modern History of Tibet

    Institute of Scientific and Technical Information of China (English)

    2005-01-01

    Authored by Xu Guangzhi, this book is a subsidiary project of Research Into Traditional Culture and History (of the PRC Ministry of Education) conducted by China Tibetology Research Institute of Tibet University. The book combines modern history of Tibet with modern history of China as a whole. It tells the close ties between various members of the Chinese nation.

  5. Adult learning in modernity

    DEFF Research Database (Denmark)

    Rasmussen, Palle

    2007-01-01

    The paper discusses the conditions for the growth of adult education in modern societies. It is argued that in modern adult life individual biographical reflection plays an increasing role, not only for educational and occupational choice but also in the process of identity formation and emotional...

  6. Liquid Modernity & Late Capitalism

    DEFF Research Database (Denmark)

    Hansen, Claus D.

    In Liquid Modernity, Bauman portrays Adorno and the rest of the early Frankfurt School as sociologists and thinkers belonging to the ‘heavy’ phase of modernity. In other words, they are deemed irrelevant to the discussion of current sociological time diagnoses and the purpose of critique under co...

  7. Understanding modern transparency

    NARCIS (Netherlands)

    Meijer, A.J.|info:eu-repo/dai/nl/172436729

    2009-01-01

    Proponents and opponents fiercely debate whether computer-mediated transparency has a positive effect on trust in the public sector. This article enhances our understanding of transparency by presenting three perspectives: a premodern, modern and post-modern perspective, and analyzing the basic

  8. Early Modern Philosophical Systems

    NARCIS (Netherlands)

    L. van Bunge (Wiep)

    2014-01-01

    textabstractThe occurrence of an entry on early modern philosophical systems in an encyclopaedia of Neo-Latin studies is fraught with complications, if only on account of the gradual disappearance during the early modern period of Latin as the main vehicle of philosophical communication. What

  9. Mod den moderne skole

    DEFF Research Database (Denmark)

    Vindum, Kjeld; Birk Morgen, Pernille

    2003-01-01

    Gennemgang af fem skoler som eksemplificerer væsentlige udviklingstrin i overgangen fra det sene 1800 tals etageskolebygninger til det moderne skolebyggeris gennemsalg i 1930erne.......Gennemgang af fem skoler som eksemplificerer væsentlige udviklingstrin i overgangen fra det sene 1800 tals etageskolebygninger til det moderne skolebyggeris gennemsalg i 1930erne....

  10. Spotting modern Copenhagen

    DEFF Research Database (Denmark)

    Ovesen, Hans; Bøgelund, Helle; Darger, Birgitte

    2002-01-01

    Med udgangspunkt i Københavns Rådhus og området omkring Banegårdspladsen analyseres Københavns indtræden i det moderne......Med udgangspunkt i Københavns Rådhus og området omkring Banegårdspladsen analyseres Københavns indtræden i det moderne...

  11. Productions, modern (Scandinavia)

    DEFF Research Database (Denmark)

    Lech, Marcel Lysgaard

    2017-01-01

    Greek comedy has never been as popular on the modern Scandinavian scene as Greek tragedy, but one play stands out among them all as a modern classic, Aristophanes’ Lysistrata, which has inspired many adaptations not only on the stage, but also in radio and cinema....

  12. Homogeneous cation exchange membrane by radiation grafting

    International Nuclear Information System (INIS)

    Kolhe, Shailesh M.; G, Agathian; Ashok Kumar

    2001-01-01

    Preparation of a strong cation exchange membrane by radiation grafting of styrene on to polyethylene (LDPE) film by mutual irradiation technique in the presence of air followed by sulfonation is described. The grafting has been carried out in the presence of air and without any additive. Low dose rate has been seen to facilitate the grafting. Further higher the grafting percentage more is the exchange capacity. The addition of a swelling agent during the sulfonation helped in achieving the high exchange capacity. The TGA-MASS analysis confirmed the grafting and the sulfonation. (author)

  13. Test manufacture of the canister insert 135

    International Nuclear Information System (INIS)

    Raiko, H.

    2005-10-01

    This report describes the insert-manufacturing test of a disposal canister for spent nuclear fuel that was made by Metso Foundries Jyvaeskylae Oy, in June 2004 on contract for Posiva Oy. The test manufacture was a part of the co-operation development programme of encapsulation technology between SKB AB and Posiva Oy. Insert casting was specified according to the current manufacturing specifications of SKB. The canister insert was of BWR-type with integral bottom. This was the second trial manufacture of this type of insert in Finland and, in total, the third test manufacture of insert by Metso Foundries Jyvaeskylae Oy. The result fulfilled all the requirements but the material mechanical properties of the cast material. The measured ultimate strength and elongation at rupture were lower than specified in the upper part of the cast. The reason for this was revealed in the metallurgical investigation of the cast material. The cast contained slag (dross). Avoiding the dross formation will be the most demanding challenge of the forthcoming development of the cast procedure. (orig.)

  14. Test manufacture of a canister insert

    International Nuclear Information System (INIS)

    Raiko, H.

    2004-11-01

    This report describes the insert-manufacturing test of a disposal canister for spent nuclear fuel that was made by Metso Paper Oy, Jyvaeskylae Foundry, in 2003 on contract for Posiva Oy. The test manufacture was a part of the co-operation development programme of encapsulation technology between SKB AB and Posiva Oy. Insert casting was specified according to the current manufacturing specifications of SKB. The canister insert was of BWR-type with integral bottom. This was the first trial manufacture of this type of insert in Finland and, in total, the second test manufacture of insert by Metso Paper. The result fulfilled all the requirements but the material mechanical properties and metallurgical structure of the cast material. The measured tensile strength, ultimate strength and elongation at rupture were lower than specified. The reason for this was revealed in the metallurgical investigation of the cast material. The nodulizing of the graphite was not occurred during the casting process according to the requirements. (orig.)

  15. ACL ideal graft: MRI correlation between ACL and humstrings, PT and QT

    Directory of Open Access Journals (Sweden)

    Fabiano Kupczik

    2013-09-01

    Full Text Available OBJECTIVE: The objective of this study was to measure in MRI scans, the size of the origin, insertion and length of the anterior cruciate ligament and possible graft for reconstruction surgery in case of injury. Besides this, there was a cross between statistical data to test the hypothesis of proportional relationship between these anatomical extent. MATERIALS AND METHODS: 52 MRI examinations performed between 2008 and 2011 were valued at random in a longitudinal retrospective epidemiological study. To measure the width of the ACL was used coronal oblique to the length of the sagittal section, for inserting the tibial coronal femoral insertion and was also used oblique coronal section. RESULTS: The average diameter of the ACL was 4.80 mm (3.1-8.3 mm, with a length of 3.8 cm (2.85-4.5 cm. The origin ranged from 9.7 mm to 15.4 mm. The average insertion on the tibia was 13.3 mm. The average diameter of the semi-tendinous was 4.38 mm and the average diameter was 3.42 mm gracilis. The quadriceps presented diameter of 7.67 mm, a length of 35.34 mm and 4.54 mm patellar tendon diameter and 26.62 mm in average length. CONCLUSION: These data provide important information for the pre-operative surgeon, facilitating preoperative planning and providing viable alternatives and avoiding inadequate grafts.

  16. Studies on radiation-induced graft polymerization

    International Nuclear Information System (INIS)

    Omichi, Hideki

    1978-09-01

    Radiation-induced graft polymerization is used extensively to improve physical properties of polymers, but few processes are now commercialized. The reason for this is partly inadequate basic research on the reaction and partly the difficulty in developing the grafting process with large radiation source. Firstly, new techniques are proposed of studying kinetics of the graft polymerization in heterogeneous system. Based on the grafting yield, the molecular weight of graft chains, and the amount of radicals given by ESR and activation analysis, kinetic parameters are obtained and the reaction mechanism of grafting process is discussed. Secondly, the development of grafting process of poly (vinyl chloride)-butadiene is described. By study of the reaction, process design, construction and operation of the pilot plant, and economic analysis of the process, this process with 60 Co gamma ray sources is shown to be industrially promising. (author)

  17. Dynamics of bone graft healing around implants

    Directory of Open Access Journals (Sweden)

    Narayan Venkataraman

    2015-01-01

    A few questions arise pertaining to the use of bone grafts along with implants are whether these are successful in approximation with implant. Do they accelerate bone regeneration? Are all defects ultimately regenerated with new viable bone? Is the bone graft completely resorbed or integrated in new bone? Does the implant surface characteristic positively affect osseointegration when used with a bone graft? What type of graft and implant surface can be used that will have a positive effect on the healing type and time? Finally, what are the dynamics of bone graft healing around an implant? This review discusses the cellular and molecular mechanisms of bone graft healing in general and in vicinity of another foreign, avascular body, namely the implant surface, and further, the role of bone grafts in osseointegration and/or clinical success of the implants.

  18. A novel technique for distal fingertip replantation: Polypropylene suture guided interpositional vein graft.

    Science.gov (United States)

    Dadaci, Mehmet; Ince, Bilsev; Altuntas, Zeynep; Bitik, Ozan; Uzun, Hakan; Bilgen, Fatma

    2015-05-04

    Despite current advances in microsurgery, fingertip replantation is still controversial, mainly due to its difficulty and cost. The purpose of this study is to describe a new technique of interposition vein graft guided by polypropylene suture in distal fingertip replantation. A total of eight consecutive Tamai zone 1 fingertip replantations performed by the same author were included. All replantations were performed using interposition vein graft guided by polypropylene suture. This technique involved a vein graft of ∼ 2 cm, with appropriate calibration, obtained from the volar part of the forearm and a 2-0 polyprolene suture passed through the interposition vein graft. Then, a polypropylene suture guide carrying the vein graft was inserted into the artery. The anastomosis was easily performed with the aid of 10-0 or 11-0 nylon in a bloodless medium and without encountering the posterior wall problem. Average surgery time was 2.5 hours (range = 2-3 hours). Among eight Tamai zone 1 replantations, six were successful (75%). There were two replantations lost because of arterial failure. This technique may ease fingertip replantations and increase the success rate for Tamai zone 1 injuries.

  19. Vascular Reconstruction Technique Using a Tubular Graft for Leiomyosarcoma of the Inferior Vena Cava: A Case Report

    Directory of Open Access Journals (Sweden)

    C. Higutchi

    Full Text Available Objective/background: This study is a case report that addresses the key aspects of vascular reconstruction, as well as the intraoperative complications, postoperative morbidity, and possibility of adjunctive therapy. Methods: This article reports the case of a 46 year old female patient with a leiomyosarcoma located in the middle segment of the inferior vena cava (between the renal and hepatic veins who underwent surgical resection with vena cava reconstruction and insertion of a tubular graft made of a synthetic material. Results: This case report reveals that surgical resection of the tumor with the insertion of a smaller-caliber tubular graft provide better patency of the vena cava reconstruction, which was maintained for a year after surgery. In addition, the patient was asymptomatic for lower limb edema, despite having a local recurrence after one year. Surgical resection is the treatment of choice for leiomyosarcoma of the inferior vena cava (LIVC and is the only therapy that offers a chance of cure. Several surgical techniques are used for this condition, especially, reconstruction with a vascular graft using natural or synthetic materials. Conclusion: Due to the aggressiveness of the disease, this study suggests that surgical intervention used may have no influence on a patient's survival outcome. However, vascular reconstruction with a smaller-caliber tubular graft may yield a better prognosis for patients in terms of postoperative symptoms, such as edema and thrombosis. Keywords: Inferior vena cava, Leiomyosarcoma, Synthetic vascular grafting

  20. RERTR-12 Insertion 1 Irradiation Summary Report

    International Nuclear Information System (INIS)

    Perez, D.M.; Lillo, M.A.; Chang, G.S.; Woolstenhulme, N.E.; Roth, G.A.; Wachs, D.M.

    2012-01-01

    The Reduced Enrichment for Research and Test Reactor (RERTR) experiment RERTR-12 was designed to provide comprehensive information on the performance of uranium-molybdenum (U-Mo) based monolithic fuels for research reactor applications. RERTR-12 insertion 1 includes the capsules irradiated during the first two irradiation cycles. These capsules include Z, X1, X2 and X3 capsules. The following report summarizes the life of the RERTR-12 insertion 1 experiment through end of irradiation, including as-run neutronic analysis results, thermal analysis results and hydraulic testing results.

  1. RERTR-12 Insertion 2 Irradiation Summary Report

    International Nuclear Information System (INIS)

    Perez, D.M.; Chang, G.S.; Wachs, D.M.; Roth, G.A.; Woolstenhulme, N.E.

    2012-01-01

    The Reduced Enrichment for Research and Test Reactor (RERTR) experiment RERTR-12 was designed to provide comprehensive information on the performance of uranium-molybdenum (U-Mo) based monolithic fuels for research reactor applications.1 RERTR-12 insertion 2 includes the capsules irradiated during the last three irradiation cycles. These capsules include Z, Y1, Y2 and Y3 type capsules. The following report summarizes the life of the RERTR-12 insertion 2 experiment through end of irradiation, including as-run neutronic analysis results, thermal analysis results and hydraulic testing results.

  2. Installation of the LHC experimental insertions

    CERN Document Server

    Bartolome-Jimenez, S

    2004-01-01

    The installation of the LHC experimental insertions, and particularly the installation of the low-beta quadrupoles, raises many technical challenges due to the stringent alignment specifications and to the difficulty of access in very confined areas. The compact layout with many lattice elements, vacuum components, beam control instrumentation and the presence of shielding does not allow for any improvisation in the installation procedure. This paper reviews all the constraints that need to be taken into account when installing the experimental insertions. It describes the chronological sequence of installation and discusses the technical solutions that have been adopted.

  3. INSTALLATION OF THE LHC EXPERIMENTAL INSERTIONS

    CERN Document Server

    Bartolome-Jimenez, S

    2004-01-01

    The installation of the LHC experimental insertions, and particularly the installation of the Low-Beta quadrupoles, raises many technical challenges due to the stringent alignment specifications and to the difficulty of access in very confined areas. The compact layout with many lattice elements, vacuum components, beam control instrumentation and the presence of shielding does not allow for any improvisation in the installation procedure. This paper reviews all the constraints that need to be taken into account when installing the experimental insertions. It describes the chronological sequence of installation and discusses the technical solutions that have been adopted.

  4. Compact insert design for cryogenic pressure vessels

    Energy Technology Data Exchange (ETDEWEB)

    Aceves, Salvador M.; Ledesma-Orozco, Elias Rigoberto; Espinosa-Loza, Francisco; Petitpas, Guillaume; Switzer, Vernon A.

    2017-06-14

    A pressure vessel apparatus for cryogenic capable storage of hydrogen or other cryogenic gases at high pressure includes an insert with a parallel inlet duct, a perpendicular inlet duct connected to the parallel inlet. The perpendicular inlet duct and the parallel inlet duct connect the interior cavity with the external components. The insert also includes a parallel outlet duct and a perpendicular outlet duct connected to the parallel outlet duct. The perpendicular outlet duct and the parallel outlet duct connect the interior cavity with the external components.

  5. ALS insertion device block measurement and inspection

    International Nuclear Information System (INIS)

    Marks, S.; Carrieri, J.; Cook, C.; Hassenzahl, W.V.; Hoyer, E.; Plate, D.

    1991-05-01

    The performance specifications for ALS insertion devices require detailed knowledge and strict control of the Nd-Fe-B permanent magnet blocks incorporated in these devices. This paper describes the measurement and inspection apparatus and the procedures designed to qualify and characterize these blocks. A detailed description of a new, automated Helmholtz coil facility for measurement of the three components of magnetic moment is included. Physical block inspection and magnetic moment measurement procedures are described. Together they provide a basis for qualifying blocks and for specifying placement of blocks within an insertion devices' magnetic structures. 1 ref., 4 figs

  6. Neutron absorber inserts for 55-gal drums

    International Nuclear Information System (INIS)

    Wilson, R.E.; Kim, Y.S.; Toffer, H.

    2000-01-01

    Transport and temporary storage of more than 200 g of fissile material in 55-gal drums at the Rocky Flats Environmental Technology Site (RFETS) have received significant attention during the cleanup mission. This paper discusses successful applications and results of extensive computer studies. Interim storage and movement of fissile material in excess of standard drum limits (200 g) in a safe configuration have been accomplished using special drum inserts. Such inserts have constrained the contents of a drum to two 4-ell bottles. The content of the bottles was limited to 600 g Pu or U in solution or a total of 1200 g for the entire drum. The inserts were a simple design constructed of stainless steel, forming a vertical cylindrical pipe into which two bottles, one on top of the other, could be centered in the drum. The remaining drum volume was configured to preclude any additional bottle placement external to the vertical cylinder. Such inserts in drums were successfully used in moving high-concentration solution from one building to another for chemical processing. Concern about the knowledge of fissile material concentration in bottles prompted another study for drum inserts. The past practice had been to load up to fourteen 4-ell bottles into 55-gal drums, provided the fissile material concentration was < 6 g fissile/ell, and the total drum contents of 200 g fissile was not exceeded. Only one determination of the solution concentration was needed. An extensive safety analysis concluded that a single measurement of bottle content could not ensure compliance with double-contingency-criterion requirements. A second determination of the bottle contents was required before bottles could be placed in a 55-gal drum. Al alternative to a dual-measurement protocol, which is for bolstering administrative control, was to develop an engineered safety feature that would eliminate expensive tests and administrative decisions. A drum insert design was evaluated that would

  7. Septal graft in laryngeal reconstruction

    International Nuclear Information System (INIS)

    Bahannan, Abdulrahman; Slavicek, A.; Taudy, M.; Chovanec, M.

    2006-01-01

    A 62-year-old woman presented with symptoms of dyspnea. Ultrasonography and computed tomography examinations revealed mass extending from the cricoid cartilage to the left lobe of thyroid gland and thyroid cartilage. Cytology revealed possibility of cartilaginous origin, which was proven to be chondrosarcoma (Grade 1) from the biopsy specimen obtained during panendosopy. She underwent one stage radical resection and immediate reconstruction of laryngeal skeleton defect by mucocartilaginous graft from the nasal septum. Her postoperative course was optimal with preservation of the laryngeal functions. Twenty-eight months postoperatively, she had to undergo total laryngectomy as a salvage procedure for the advanced local recurrence. We report on the relatively easy technique for functional reconstruction of the large laryngeal defect with the employment cartilage graft from the nasal septum. (author)

  8. Determining the degree of grafting for poly (vinylidene fluoride) graft-copolymers using fluorine elemental analysis

    International Nuclear Information System (INIS)

    Yu Yang; Zhang Bowu; Yang Xuanxuan; Deng Bo; Li Linfan; Yu Ming; Li Jingye

    2011-01-01

    Acrylic acid (AAc) and styrene (St) were grafted onto poly (vinylidene fluoride) (PVDF) powder or membrane samples by pre-irradiation graft copolymerization. The grafted chains were proved by FT-IR spectroscopy analysis. The degree of grafting (DG) of the grafted PVDF was determined by fluorine elemental analysis (FEA) method, and was compared with the DGs determined by weighing method, acid-base back titration method and quantitative FT-IR method. The results show that the FEA method is accurate, convenient and universal, especially for the grafted polymer powders. (authors)

  9. Anterior cruciate ligament reconstruction with tibial attachment preserving hamstring graft without implant on tibial side

    Directory of Open Access Journals (Sweden)

    Skand Sinha

    2018-01-01

    Full Text Available Background: Tibial attachment preserving hamstring graft could prevent potential problems of free graft in anterior cruciate ligament (ACL reconstruction such as pull out before graft-tunnel healing or rupture before ligamentization. Different implants have been reportedly used for tibial side fixation with this technique. We investigated short-term outcome of ACL reconstruction (ACLR with tibial attachment sparing hamstring graft without implant on the tibial side by outside in technique. Materials and Methods: Seventy nine consecutive cases of ACL tear having age of 25.7 ± 6.8 years were included after Institutional Board Approval. All subjects were male. The mean time interval from injury to surgery was of 7.5 ± 6.4 months. Hamstring tendons were harvested with open tendon stripper leaving the tibial insertion intact. The free ends of the tendons were whip stitched, quadrupled, and whip stitched again over the insertion site of hamstring with fiber wire (Arthrex. Single bundle ACLR was done by outside in technique and the femoral tunnel was created with cannulated reamer. The graft was pulled up to the external aperture of femoral tunnel and fixed with interference screw (Arthrex. The scoring was done by Lysholm, Tegner, and KT 1000 by independent observers. All cases were followed up for 2 years. Results: The mean length of quadrupled graft attached to tibia was 127.65 ± 7.5 mm, and the mean width was 7.52 ± 0.78 mm. The mean preoperative Lysholm score of 47.15 ± 9.6, improved to 96.8 ± 2.4 at 1 year. All cases except two returned to the previous level of activity after ACLR. There was no significant difference statistically between preinjury (5.89 ± 0.68 and postoperative (5.87 ± 0.67 Tegner score. The anterior tibial translation (ATT (KT 1000 improved from 11.44 ± 1.93 mm to 3.59 ± 0.89 mm. The ATT of operated knee returned to nearly the similar value as of the opposite knee (3.47 ± 1.16 mm. The Pivot shift test was negative in

  10. The use of radiation-induced graft polymerization for modification of polymer track membranes

    International Nuclear Information System (INIS)

    Shtanko, N.I.; Kabanov, V.Ya.; Apel, P.Yu.; Yoshida, M.

    1999-01-01

    Track membranes (TM) made of poly(ethylene terephtalate) (PET) and polypropylene (PP) films have a number of peculiarities as compared with other ones. They have high mechanical strength at a low thickness, narrow pore size distribution, low content of extractables. However, TM have some disadvantages such as low chemical resistance in alkaline media (PET TM), the low water flow rate due to the hydrophobic nature of their surface. The use of radiation-induced graft polymerization makes it possible to improve the basic characteristics of TM. In this communication our results on the modification of PET and PP TM are presented. The modified membranes were prepared by radiation-induced graft polymerization from the liquid phase. Three methods of grafting were used: (a) the direct method in argon atmosphere; (b) the pre-irradiation of TM in air followed by grafting in argon atmosphere; (c) pre-irradiation in vacuum followed by grafting in vacuum without contacting oxygen. The aim of the work was to investigate some properties of TM modified by grafted poly(methylvinyl pyridine) (PMVP) and poly(N-isopropylacrylamide) (PNIPAAM). It was shown that the modification of TM with hydrophilic polymer results in the growth of the water flow rate. In the past few years many works have been devoted to the synthesis of new polymers - the so-called 'intelligent' materials - such as PNIPAAM. However, it is very difficult to make thin membranes of this polymer. Recently, it has been proposed to manufacture composite membranes by grafting stimulus-responsive polymers onto TM. Following this principle, we prepared thermosensitive membranes by the radiation-induced graft polymerization of N-isopropylacrylamide (NIPAAM) onto PET TM. PET TM with the pore size of about 1 μm and pore density of 10 6 cm -2 were first inserted into a solution of NIPAAM containing inhibitor of homopolymerization (CuCl 2 ) and then exposed to the γ-rays from a 60 Co source. The transport properties of the

  11. The use of radiation-induced graft polymerization for modification of polymer track membranes

    Science.gov (United States)

    Shtanko, N. I.; Kabanov, V. Ya.; Apel, P. Yu.; Yoshida, M.

    1999-05-01

    Track membranes (TM) made of poly(ethylene terephtalate) (PET) and polypropylene (PP) films have a number of peculiarities as compared with other ones. They have high mechanical strength at a low thickness, narrow pore size distribution, low content of extractables. However, TM have some disadvantages such as low chemical resistance in alkaline media (PET TM), the low water flow rate due to the hydrophobic nature of their surface. The use of radiation-induced graft polymerization makes it possible to improve the basic characteristics of TM. In this communication our results on the modification of PET and PP TM are presented. The modified membranes were prepared by radiation-induced graft polymerization from the liquid phase. Three methods of grafting were used: (a) the direct method in argon atmosphere; (b) the pre-irradiation of TM in air followed by grafting in argon atmosphere; (c) pre-irradiation in vacuum followed by grafting in vacuum without contacting oxygen. The aim of the work was to investigate some properties of TM modified by grafted poly(methylvinyl pyridine) (PMVP) and poly(N-isopropylacrylamide) (PNIPAAM). It was shown that the modification of TM with hydrophilic polymer results in the growth of the water flow rate. In the past few years many works have been devoted to the synthesis of new polymers - the so-called "intelligent" materials - such as PNIPAAM. However, it is very difficult to make thin membranes of this polymer. Recently, it has been proposed to manufacture composite membranes by grafting stimulus-responsive polymers onto TM. Following this principle, we prepared thermosensitive membranes by the radiation-induced graft polymerization of N-isopropylacrylamide (NIPAAM) onto PET TM. PET TM with the pore size of about 1 μm and pore density of 10 6 cm -2 were first inserted into a solution of NIPAAM containing inhibitor of homopolymerization (CuCl 2) and then exposed to the γ-rays from a 60Co source. The transport properties of the grafted

  12. [Autologous fat grafting in children].

    Science.gov (United States)

    Baptista, C; Bertrand, B; Philandrianos, C; Degardin, N; Casanova, D

    2016-10-01

    Lipofilling or fat grafting transfer is defined as a technique of filling soft tissue by autologous fat grafting. The basic principle of lipofilling is based on a harvest of adipose tissue, followed by a reinjection after treatment. Lipofilling main objective is a volume defect filling, but also improving cutaneous trophicity. Lipofilling specificities among children is mainly based on these indications. Complications of autologous fat grafting among children are the same as those in adults: we distinguish short-term complications (intraoperative and perioperative) and the medium and long-term complications. The harvesting of fat tissue is the main limiting factor of the technique, due to low percentage of body fat of children. Indications of lipofilling among children may be specific or similar to those in adults. There are two types of indications: cosmetic, in which the aim of lipofilling is correcting a defect density, acquired (iatrogenic, post-traumatic scar) or malformation (otomandibular dysplasia, craniosynostosis, Parry Romberg syndrom, Poland syndrom, pectus excavatum…). The aim of functional indications is correcting a velar insufficiency or lagophthalmos. In the paediatric sector, lipofilling has become an alternative to the conventional techniques, by its reliability, safety, reproducibility, and good results. Copyright © 2016 Elsevier Masson SAS. All rights reserved.

  13. Modern technologies in Endodontics

    Directory of Open Access Journals (Sweden)

    Alfredo Iandolo

    2016-06-01

    Conclusions: The positive results highlighted by these clinical cases demonstrate how the use of modern technologies are essential to avoid iatrogenic injury, and guarantee, on the other hand, safe and reproducible results.

  14. Etymology and Modern Linguistics

    Science.gov (United States)

    Malkiel, Yakov

    1975-01-01

    Discusses the estrangement between etymology and modern linguistics, and concludes that a reconciliation between spatio-temporal linguistics and etymology must occur, because without it, both disciplines are doomed to inanition. (Author/AM)

  15. INFECTIVE ENDOCARDITIS: MODERN COURSE

    Directory of Open Access Journals (Sweden)

    T. L. Vinogradova

    2014-07-01

    Full Text Available The paper presents the characteristic features of the modern course of infective endocarditis. Unresolved questions of classification of diseaseand drug therapy are discussed. Clearly defined indications for surgical treatment of endocarditis.

  16. Anthropology and Multiple Modernities

    DEFF Research Database (Denmark)

    Thomassen, Bjørn

    “modernities” over the last 10 years, this paper wishes to address the analytical usefulness of this conceptual development. What is it about these concepts that make them useful as we try to capture the World today? Rather than providing any substantial definitions as to what those modernities are about (or...... what they are not about), anthropologists have used ethnographies to demonstrate how modernities are lived and constructed differently in different cultural contexts. To a very large extent, anthropologists intend these multiple modernities to refer to the interplay between local and global...... configurations. However, if the current pluralizing of modernity ultimately serves to describe the variety of cultural forms that co-exist in the World today, the analytical value of the concept risks being watered down, and little is gained in perspective. Arguably, other concepts would have served the purpose...

  17. Genealogies of Modern Technology

    DEFF Research Database (Denmark)

    Riis, Søren

    2008-01-01

    Does modern technology differ from ancient technology and does it have a unique essence? This twofold question opens one of Martin Heidegger's most influential philosophical inquiries, The Question Concerning Technology. The answer Heidegger offers has inspired various critiques and appraisals from...... a vast number of contemporary scholars of technology.1 Heidegger's answer is traditionally thought to suggest a great difference between ancient and modern technology. However, by re-examining Heidegger's text, it is possible to discover previously ignored or misunderstood lines of thoughts that affirm...... a multi-stable interpretation of the origin of modern technology. In what follows, we shall see how The Question Concerning Technology in fact supports three different genealogies of modern technology...

  18. Modern optimization with R

    CERN Document Server

    Cortez, Paulo

    2014-01-01

    The goal of this book is to gather in a single document the most relevant concepts related to modern optimization methods, showing how such concepts and methods can be addressed using the open source, multi-platform R tool. Modern optimization methods, also known as metaheuristics, are particularly useful for solving complex problems for which no specialized optimization algorithm has been developed. These methods often yield high quality solutions with a more reasonable use of computational resources (e.g. memory and processing effort). Examples of popular modern methods discussed in this book are: simulated annealing; tabu search; genetic algorithms; differential evolution; and particle swarm optimization. This book is suitable for undergraduate and graduate students in Computer Science, Information Technology, and related areas, as well as data analysts interested in exploring modern optimization methods using R.

  19. Modernizing Electricity Delivery

    Science.gov (United States)

    Explains how modern grid, or smart grid, investments can enable grid operators to respond faster to changes in grid conditions and allow for two-way communication between utilities and electricity end-users.

  20. Direct random insertion mutagenesis of Helicobacter pylori.

    NARCIS (Netherlands)

    Jonge, de R.; Bakker, D.; Vliet, van AH; Kuipers, E.J.; Vandenbroucke-Grauls, C.M.J.E.; Kusters, J.G.

    2003-01-01

    Random insertion mutagenesis is a widely used technique for the identification of bacterial virulence genes. Most strategies for random mutagenesis involve cloning in Escherichia coli for passage of plasmids or for phenotypic selection. This can result in biased selection due to restriction or

  1. Direct random insertion mutagenesis of Helicobacter pylori

    NARCIS (Netherlands)

    de Jonge, Ramon; Bakker, Dennis; van Vliet, Arnoud H. M.; Kuipers, Ernst J.; Vandenbroucke-Grauls, Christina M. J. E.; Kusters, Johannes G.

    2003-01-01

    Random insertion mutagenesis is a widely used technique for the identification of bacterial virulence genes. Most strategies for random mutagenesis involve cloning in Escherichia coli for passage of plasmids or for phenotypic selection. This can result in biased selection due to restriction or

  2. Angiotensin Converting Enzyme Insertion/Deletion Gene ...

    African Journals Online (AJOL)

    Angiotensin Converting Enzyme Insertion/Deletion Gene Polymorphism: An Observational Study among Diabetic Hypertensive Subjects in Malaysia. ... Methods: The pharmacological effect of ACE inhibition on mean arterial pressure (MAP) and glomerular filtration rate (GFR) were observed among a total of 62 subjects for ...

  3. Insertion Loss of Personal Protective Clothing

    International Nuclear Information System (INIS)

    Shull, D.J.

    1999-01-01

    The use of personal protective clothing that covers the head is a common practice in many industries. Such personal protective clothing will impact the sound pressure level and the frequency content of sounds to which the wearer will be exposed. The use of such clothing, then, may impact speech and alarm audibility. A measure of the impact of such clothing is its insertion loss. Insertion loss measurements were performed on four types of personal protective clothing in use by Westinghouse Savannah River Company personnel which utilize cloth and plastic hood configurations to protect the head. All clothing configurations tested at least partially cover the ears. The measurements revealed that insertion loss of the items tested was notable at frequencies above 1000 Hz only and was a function of material stiffness and acoustic flanking paths to the ear. Further, an estimate of the clothing's noise reduction rating reveals poor performance in that regard, even though the insertion loss of the test articles was significant at frequencies at and above 1000 Hz.'

  4. Aspects of insertion in random trees

    NARCIS (Netherlands)

    Bagchi, Arunabha; Reingold, E.M.

    1982-01-01

    A method formulated by Yao and used by Brown has yielded bounds on the fraction of nodes with specified properties in trees bult by a sequence of random internal nodes in a random tree built by binary search and insertion, and show that in such a tree about bounds better than those now known. We

  5. Patients Comprehension of Pharmaceutical Package Inserts ...

    African Journals Online (AJOL)

    Tropical Journal of Pharmaceutical Research December 2015; 14 (12): ... Available online at http://www.tjpr.org ... patients/consumers about PPI. ... the perception of outpatients of Karachi about ... Do you store the medication at the temperature specified in the package insert ... drugs available in local market of Pakistan was.

  6. Concepts in modern parenting

    OpenAIRE

    Dolenc, Anja

    2011-01-01

    The main focus of my dissertation represents changes in parenthood, which are a consequence of a wider specter of social changes. Besides, I am interested in modern trends of educational strategies and how parents deal with the demands of society and those of professional public for nothing less than a perfect parenthood. Theoretical cognitions are divided into three parts: in the first one, new forms of family and social changes which affected the development of the modern family are describ...

  7. Turbine maintenance and modernization

    Energy Technology Data Exchange (ETDEWEB)

    Unga, E. [Teollisuuden Voima Oy, Olkiluoto (Finland)

    1998-12-31

    The disturbance-free operation of the turbine plant plays an important role in reaching good production results. In the turbine maintenance of the Olkiluoto nuclear power plant the lifetime and efficiency of turbine components and the lifetime costs are taken into account in determining the turbine maintenance and modernization/improvement program. The turbine maintenance program and improvement/modernization measures taken in the plant units are described in this presentation. (orig.)

  8. Badges of modern slavery

    OpenAIRE

    Paz-Fuchs, Amir

    2016-01-01

    Notwithstanding the 19th century formal abolition of slavery as legal ownership of people, modern slavery and forced labour have not been consigned to the past. In fact, their existence is more widespread, and made more difficult to tackle due to the lack of formal, legal criteria. This article suggests that reference to the past, historical institutions reveals seven ‘badges of slavery’ that are helpful in identifying occurrences of modern slavery and forced labour. These are: humiliation, o...

  9. Turbine maintenance and modernization

    Energy Technology Data Exchange (ETDEWEB)

    Unga, E [Teollisuuden Voima Oy, Olkiluoto (Finland)

    1999-12-31

    The disturbance-free operation of the turbine plant plays an important role in reaching good production results. In the turbine maintenance of the Olkiluoto nuclear power plant the lifetime and efficiency of turbine components and the lifetime costs are taken into account in determining the turbine maintenance and modernization/improvement program. The turbine maintenance program and improvement/modernization measures taken in the plant units are described in this presentation. (orig.)

  10. A Modern Education

    OpenAIRE

    Macfarlane, Alan

    2015-01-01

    What is western modernity and how did education help to shape that modernity? Through an examination of schooling in elite British institutions, Alan Macfarlane tries to answer these question, particularly to explain the choices facing China and other emerging superpowers. One section looks at his English education; society and power, play and performance, head and heart, spirit and character. Another looks at education more widely: how it shaped the English world, English and Continental Eur...

  11. Modern mathematics made simple

    CERN Document Server

    Murphy, Patrick

    1982-01-01

    Modern Mathematics: Made Simple presents topics in modern mathematics, from elementary mathematical logic and switching circuits to multibase arithmetic and finite systems. Sets and relations, vectors and matrices, tesselations, and linear programming are also discussed.Comprised of 12 chapters, this book begins with an introduction to sets and basic operations on sets, as well as solving problems with Venn diagrams. The discussion then turns to elementary mathematical logic, with emphasis on inductive and deductive reasoning; conjunctions and disjunctions; compound statements and conditional

  12. Modernization of credit relations

    Directory of Open Access Journals (Sweden)

    S.V. Volosovich

    2015-03-01

    Full Text Available Nowadays it is essential to modernize credit relations in the conditions of global economy transformations. This is due to the influence of integration processes on credit relations and transformation of the risks inherent in the credit field. The purpose of this article is to develop measures that help to improve the efficiency of interaction of credit relations’ participants. Modernization of credit relations is based on the interaction of its main and indirect subjects who belong to the subsystems of loans granting, deposits attraction and provision of related services. Its goal is to pass from extensive to intensive model of interaction between the subjects of credit relations. Components of the credit relations modernization are the following: institutional modernization, which is based on the interaction of credit relations’ subjects, and ensures the development of competition in all credit market’s segments, the creation of its corresponding infrastructure, qualitative change in the approaches of regulation and supervision; technological modernization, which involves the formation of joint products on the credit market and the formation of an integrated informational and analytical system. In the result of the credit relations’ modernization it is expected to achieve synergies between the subjects of credit relations, that will lead to changes in the business architecture of the financial market.

  13. Politics of modern muslim subjectivities

    DEFF Research Database (Denmark)

    Jung, Dietrich; Petersen, Marie Juul; Sparre, Sara Lei

    Examining modern Muslim identity constructions, the authors introduce a novel analytical framework to Islamic Studies, drawing on theories of successive modernities, sociology of religion, and poststructuralist approaches to modern subjectivity, as well as the results of extensive fieldwork...

  14. COMPARATIVE STUDY OF EARLY POSTPARTUM IUCD INSERTION TO INTERVAL IUCD INSERTION

    Directory of Open Access Journals (Sweden)

    Shibani Devi

    2016-07-01

    Full Text Available INTRODUCTION According to National Family Health Survey-3, Indian women have 13% unmet need for contraception and according to District Level Household & Facility Survey-3, it is 21.3% in the postpartum period. Postpartum intrauterine contraceptive device insertion - both immediately post-placental delivery and somewhat later, but within 48 hours after delivery are options which merit consideration as the woman is likely to have a high motivation for accepting contraception and the healthcare centre provides a convenient setting for insertion of IUCD. AIM Comparison of efficacy and complications of IUCD insertions in post-placental with interval period: 6-month followup. METHOD This perspective study was conducted among 100 women: - 50 women had IUCD inserted within 10 minutes of placental delivery and 50 had insertion more than 6 weeks after delivery. They were followed till 6 months post insertion and were compared regarding early and late complications, continuation rates and expulsion rates. RESULT At the end of six months, we found higher occurrence of lower abdominal pain, heavy menstrual bleeding in case of interval insertion as compared to post-placental insertion which was statistically significant (p value-0.04 & 0.007 respectively. However, the expulsion rates of post-placental IUCD were somewhat elevated (14% compared to interval insertions (2%. Continuation rates at the end of 6 months in both the groups were 82% and 86% respectively which is comparable. CONCLUSION Post-placental IUCD is thus found to be an ideal method to meet the unmet need of postpartum women as it is easily accessible and convenient for both women and their health care providers, is associated with less discomfort and fewer side effects and allow women to obtain safe, long acting, highly effective contraception while still in the health care system.

  15. Bypass grafting to the anterior tibial artery.

    Science.gov (United States)

    Armour, R H

    1976-01-01

    Four patients with severe ischaemia of a leg due to atherosclerotic occlusion of the tibial and peroneal arteries had reversed long saphenous vein grafts to the patent lower part of the anterior tibial artery. Two of these grafts continue to function 19 and 24 months after operation respectively. One graft failed on the fifth postoperative day and another occluded 4 months after operation. The literature on femorotibial grafting has been reviewed. The early failure rate of distal grafting is higher than in the case of femoropopliteal bypass, but a number of otherwise doomed limbs can be salvaged. Contrary to widely held views, grafting to the anterior tibial artery appears to give results comparable to those obtained when the lower anastomosis is made to the posterior tibial artery.

  16. Evaluation of early coronary graft patency after coronary artery bypass graft surgery using multislice computed tomography angiography

    Directory of Open Access Journals (Sweden)

    Raissi Kamal

    2009-12-01

    Full Text Available Abstract Background Coronary artery bypass graft (CABG surgery is the standard of care in the treatment of advanced coronary artery disease, and its long-term results are affected by the failure of bypass grafts. The aim of the present study was to evaluate the early patency rate in coronary bypass grafts. Methods A total of 107 consecutive patients who underwent CABG were included in this study. Early graft patency was evaluated via computed tomography (CT angiography in the first week after surgery. Results There were a total of 366 grafts, comprised of 250 venous grafts and 116 arterial grafts. Multi-slice CT detected acute graft occlusions in 32 (8.7% of all the grafts, including 26 (10% of the 250 venous grafts and 6 (5% of the 116 arterial grafts. The patency rates obtained were 97.3% for the left internal mammary (IMA grafts, 50% for the radial artery grafts, and 50% for the right IMA grafts. Additionally, 107 (96.4% grafts to the left anterior descending artery (LAD were classified as patent, whereas 1 (30% of the 3 grafts in the left circumflex (LCX region and 1 (50% of the 2 grafts in the right coronary artery (RCA territory were found to be occluded. In the venous category, 8 (13.7% of the 58 grafts to LAD were found to be occluded. In the LCX region, 9 (8.5% of the 106 grafts were classified as occluded, while the remaining 97 (91.5% grafts were patent. The venous grafts to RCA were occluded in 9 (10.4% of the 86 grafts. Amongst the multiple preoperative, intraoperative, and postoperative factors, pump time was significantly longer in the patients with occluded grafts than in those with patent grafts (P = 0.04. Conclusion The IMA grafts had the highest early patency rate amongst the coronary bypass grafts. However, the other arterial grafts were associated with a high rate of acute occlusions.

  17. Fixation of tibial plateau fractures with synthetic bone graft versus natural bone graft: a comparison study.

    LENUS (Irish Health Repository)

    Ong, J C Y

    2012-06-01

    The goal of this study was to determine differences in fracture stability and functional outcome between synthetic bone graft and natural bone graft with internal fixation of tibia plateau metaphyseal defects.

  18. Current status of grafts and implants in rhinoplasty: Part II. Homologous grafts and allogenic implants.

    Science.gov (United States)

    Sajjadian, Ali; Naghshineh, Nima; Rubinstein, Roee

    2010-03-01

    After reading this article, the participant should be able to: 1. Understand the challenges in restoring volume and structural integrity in rhinoplasty. 2. Identify the appropriate uses of various homologous grafts and allogenic implants in reconstruction, including: (a) freeze-dried acellular allogenic cadaveric dermis grafts, (b) irradiated cartilage grafts, (c) hydroxyapatite mineral matrix, (d) silicone implants, (e) high-density polyethylene implants, (f) polytetrafluoroethylene implants, and (g) injectable filler materials. 3. Identify the advantages and disadvantages of each of these biomaterials. 4. Understand the specific techniques that may aid in the use these grafts or implants. This review specifically addresses the use of homologous grafts and allogenic implants in rhinoplasty. It is important to stress that autologous materials remain the preferred graft material for use in rhinoplasty, owing to their high biocompatibility and low risk of infection and extrusion. However, concerns of donor-site morbidity, graft availability, and graft resorption have motivated the development and use of homologous and allogenic implants.

  19. Multiple arterial grafts in coronary artery bypass grafting, Sohag University Hospital's initial experience

    Directory of Open Access Journals (Sweden)

    A.A.A. Elsayed

    2017-12-01

    Conclusions: Using multiple arterial grafts did not add a significant risk or time to the classic CABG. With accumulating evidence about better patency rate in arterial grafts, MAR is recommended especially in younger patients undergoing CABG.

  20. Graft infections after surgical aortic reconstructions

    OpenAIRE

    Berger, P.

    2015-01-01

    Prosthetic vascular grafts are frequently used to reconstruct (part) of the aorta. Every surgical procedure caries a certain risk for infection and when a prosthetic aortic graft is implanted, this may lead to an aortic graft infection (AGI). Endovascular techniques have gradually replaced open surgical reconstructions as first line of treatment for aorto-iliac diseases. Nowadays, open reconstructions are primarily reserved for patients unsuitable for endovascular reconstructions or for redo ...

  1. Alveolar Ridge Contouring with Free Connective Tissue Graft at Implant Placement: A 5-Year Consecutive Clinical Study.

    Science.gov (United States)

    Hanser, Thomas; Khoury, Fouad

    2016-01-01

    This study evaluated volume stability after alveolar ridge contouring with free connective tissue grafts at implant placement in single-tooth gaps. A total of 52 single-tooth gaps with labial volume deficiencies in the maxilla (incisors, canines, and premolars) were consecutively treated with implants and concomitant free palatal connective tissue grafts in 46 patients between 2006 and 2009. Implants had to be covered with at least 2 mm peri-implant local bone after insertion. At implant placement, a free connective tissue graft from the palate was fixed inside a labial split-thickness flap to form an existing concave buccal alveolar ridge contour due to tissue volume deficiency into a convex shape. Standardized volumetric measurements of the labial alveolar contour using a template were evaluated before connective tissue grafting and at 2 weeks, 1 year, and 5 years after implantprosthetic incorporation. Tissue volume had increased significantly (P tissue contour of the implant before connective tissue grafting to baseline (2 weeks after implant-prosthetic incorporation). Statistically, 50% of the reference points (P > .05) kept their volume from baseline to 1 year after prosthetic incorporation and from baseline to 5 years after prosthetic incorporation, respectively, whereas reference points located within the area of the implant sulcus showed a significant (P connective tissue grafting appears to be an appropriate long-term means to contour preexisting buccal alveolar volume deficiencies in single implants.

  2. A simple rescue maneuver for unfolding and centering a tightly rolled graft in Descemet membrane endothelial keratoplasty

    Directory of Open Access Journals (Sweden)

    Droutsas K

    2014-10-01

    Full Text Available Konstantinos Droutsas,1,2 Thomas Bertelmann,1 Frank M Schroeder,1 Dimitrios Papaconstantinou,2 Walter Sekundo1 1Department of Ophthalmology, Philipps University, Marburg, Germany; 2First Department of Ophthalmology, University of Athens, Medical School of Athens, Athens, Greece Abstract: A 74-year-old man underwent Descemet membrane endothelial keratoplasty (DMEK for endothelial decompensation due to Fuchs endothelial dystrophy. After descemetorhexis, the DMEK graft was inserted into the anterior chamber. However, unfolding of the graft was not possible as the graft was very tightly rolled together and the anterior chamber deep. After placing a 30G-cannula connected to an air-filled syringe inside the roll's lumen, a small air bubble was injected, which allowed the roll to open up, until it assumed a “taco” configuration around the bubble. Then, the graft was centered by pressing the posterior part of the roll against, and sweeping it over the iris. In the present case a “tight” DMEK roll was successfully unfolded by injection of a single air bubble into the roll’s lumen and centered by a “sweeping” the partialy unfolded graft over the iris. This technique allowed a controlled unfolding and centering of the DMEK graft with limited trauma to the donor endothelium and may be applied in cases where other less traumatic maneuvers are not successful. Keywords: Fuchs endothelial dystrophy, surgical technique, endothelial keratoplasty

  3. Outcomes of AV Fistulas and AV Grafts after Interventional Stent-Graft Deployment in Haemodialysis Patients

    Energy Technology Data Exchange (ETDEWEB)

    Schmelter, Christopher, E-mail: christopher.schmelter@klinikum-ingolstadt.de; Raab, Udo, E-mail: udo.raab@klinikum-ingolstadt.de [Klinikum Ingolstadt, Department of Diagnostic and Interventional Radiology (Germany); Lazarus, Friedrich, E-mail: friedrich.lazarus@klinikum-ingolstadt.de [Klinikum Ingolstadt, Department of Nephrology (Germany); Ruppert, Volker, E-mail: volker.ruppert@klinikum-ingolstadt.de [Klinikum Ingolstadt, Department of Vascular Surgery (Germany); Vorwerk, Dierk, E-mail: dierk.vorwerk@klinikum-ingolstadt.de [Klinikum Ingolstadt, Department of Diagnostic and Interventional Radiology (Germany)

    2015-08-15

    PurposeThe study was designed to assess outcomes of arteriovenous (AV) accesses after interventional stent-graft deployment in haemodialysis patients.Materials and Methods63 haemodialysis patients with 66 AV fistulas and AV grafts were treated by interventional stent-graft deployment from 2006 to 2012 at our hospital. Data of these patients were retrospectively analysed for location of deployed stent-grafts, occurrence and location of (re-)stenosis and (re-)thrombosis. Complex stenosis was the most frequent indication for stent-graft deployment (45.5 %), followed by complications of angioplasty with vessel rupture or dissection (31.8 %).ResultsA high rate of procedural success was achieved (98.5 %). The most frequent location of the deployed stent-graft was the draining vein (66.7 %). Stent-graft deployment was more frequent in AV grafts than in AV fistulas. Primary patency was 45.5 % at 6 month, 31.3 % at 12 month and 19.2 % at 24 month. Primary patency was significantly better for AV fistulas than for AV grafts with deployed stent-grafts. Patency of the deployed stent-graft was much better than overall AV access primary patency with deployed stent-graft. Re-stenosis with thrombosis was the most frequent indication for re-intervention. Most frequent location of re-stenosis was the draining vein (37.1 %), followed by stenosis at the AV access (29.5 %) and the deployed stent-graft (23.5 %).ConclusionRe-stenosis and re-thrombosis remain frequent in AV fistulas and AV grafts in haemodialysis patients despite stent-graft deployment. Re-stenosis of the deployed stent-graft is, only in the minority of the cases, responsible for AV access dysfunction.

  4. The autologus graft of epithelial tissue culture

    Directory of Open Access Journals (Sweden)

    Minaee B

    1999-08-01

    Full Text Available With the intention of research about culture and autologus graft of epithelial tissue we used 4 french Albino Rabbits with an average age of 2 months. After reproduction on the support in EMEM (Eagle's Minimum Essential Medium we used this for graft after 4 weeks. This region which grafted total replaced. After fixation of this sample and passing them through various process, histological sections were prepared. These sections were stained with H & E and masson's trichrome and studied by light microscope. We succeeded in graft. We hope in the near future by using the method of epithelium tissue culture improving to treat burned patients.

  5. Nuclear accidents and bone marrow graft

    International Nuclear Information System (INIS)

    Bernard, J.

    1988-01-01

    In case of serious contamination, the only efficacious treatment is the bone marrow grafts. The graft types and conditions have been explained. To restrict the nuclear accidents consequences, it is recommended to: - take osseous medulla of the personnel exposed to radiations and preserve it , that permits to carry out rapidly the auto-graft in case of accidents; - determine, beforehand, the HLA group of the personnel; - to register the voluntary donors names and addresses, and their HLA group, that permits to find easily a compatible donar in case of allo-graft. (author)

  6. Comparison of conventional Injection Mould Inserts to Additively Manufactured Inserts using Life Cycle Assessment

    DEFF Research Database (Denmark)

    Hofstätter, Thomas; Bey, Niki; Mischkot, Michael

    2016-01-01

    Polymer Additive Manufacturing can be used to produce soft tooling inserts for injection moulding. Compared to conventional tooling, the energy and time consumption during production are significantly lower. As the life time of such inserts is significantly shorter than the life time of traditional...... of their potential environmental impact and yield throughout the development and pilot phase. Insert geometry is particularly advantageous for pilot production and small production sizes. In this research, Life Cycle Assessment is used to compare the environmental impact of soft tooling by Additive Manufacturing...... (using Digital Light Processing) and three traditional methods for the manufacture of inserts (milling of brass, steel, and aluminium) for injection moulds during the pre-production phase....

  7. Potassium fulvate-modified graft copolymer of acrylic acid onto cellulose as efficient chelating polymeric sorbent.

    Science.gov (United States)

    Mohamed, Magdy F; Essawy, Hisham A; Ammar, Nabila S; Ibrahim, Hanan S

    2017-01-01

    Acrylic acid (AA) was graft copolymerized from cellulose (Cell) in presence of potassium fulvate (KF) in order to enhance the chemical activity of the resulting chelating polymer and the handling as well. Fourier transform infrared (FTIR) proved that KF was efficiently inserted and became a permanent part of the network structure of the sorbent in parallel during the grafting copolymerization. Scanning electron microscopy (SEM) revealed intact homogeneous structure with uniform surface. This indicates improvement of the handling, however, it was not the case for the graft copolymer of acrylic acid onto cellulose in absence of KF, which is known to be brittle and lacks mechanical integrity. Effective insertion of this co-interpenetrating agent provided more functional groups, such as OH and COOH, which improved the chelating power of the produced sorbent as found for the removal of Cu 2+ ions from its aqueous solutions (the removal efficiency reached ∼98.9%). Different models were used to express the experimental data. The results corroborated conformity of the pseudo-second order kinetic model and Langmuir isotherm model to the sorption process, which translates into dominance of the chemisorption. Regeneration of the chelating polymers under harsh conditions did not affect the efficiency of copper ions uptake up to three successive cycles. A thermodynamic investigation ensured exothermic nature of the adsorption process that became less favourable at higher temperatures. Copyright © 2016 Elsevier B.V. All rights reserved.

  8. Graft union formation in artichoke grafting onto wild and cultivated cardoon: an anatomical study.

    Science.gov (United States)

    Trinchera, Alessandra; Pandozy, Gianmarco; Rinaldi, Simona; Crinò, Paola; Temperini, Olindo; Rea, Elvira

    2013-12-15

    In order to develop a non-chemical method such as grafting effective against well-known artichoke soil borne diseases, an anatomical study of union formation in artichoke grafted onto selected wild and cultivated cardoon rootstocks, both resistant to Verticillium wilt, was performed. The cardoon accessions Belgio (cultivated cardoon) and Sardo (wild cardoon) were selected as rootstocks for grafting combinations with the artichoke cv. Romolo. Grafting experiments were carried out in the autumn and spring. The anatomical investigation of grafting union formation was conducted by scanning electron microscopy (SEM) on the grafting portions at the 3rd, 6th, 10th, 12th day after grafting. For the autumn experiment only, SEM analysis was also performed at 30 d after grafting. A high affinity between artichoke scion and cardoon rootstocks was observed, with some genotype differences in healing time between the two bionts. SEM images of scion/rootstock longitudinal sections revealed the appearance of many interconnecting structures between the two grafting components just 3d after grafting, followed by a vascular rearrangement and a callus development during graft union formation. De novo formation of many plasmodesmata between scion and rootstock confirmed their high compatibility, particularly in the globe artichoke/wild cardoon combination. Moreover, the duration of the early-stage grafting process could be influenced not only by the scion/rootstock compatibility, but also by the seasonal conditions, being favored by lower temperatures and a reduced light/dark photoperiod. Copyright © 2013 Elsevier GmbH. All rights reserved.

  9. Agitation within Mk-42 insert caused by air sparge

    International Nuclear Information System (INIS)

    Ramsey, C.J.

    1991-01-01

    Dissolution of Rocky Flats Pu alloys and Pu metal using a ''nested insert'' configuration (One Well Insert (S-3352) inside the Mk-42 Insert) will require a Nuclear Safety Study, a major assumption of which will be that the annular dissolver is well-mixed. The ''well-mixed'' assumption was theoretically and experimentally supported for alloy dissolution using the Three Well Insert, but the present situation differs significantly. In the former case, the insert was directly exposed to the agitation induced by air sparging; in the case under consideration, the One Well Insert would be shielded by the Mk-42 Insert. In an effort to determine if the ''nested insert'' approach should be pursued, the past studies and technical literature have been surveyed and an attempt made to predict the extent of mixing and bulk circulation for a ''nested insert'' configuration in the presence of air sparging

  10. Requirements of modernization strategies

    International Nuclear Information System (INIS)

    Heinbuch, R.

    1997-01-01

    Instrumentation and control contributed a major share to the current level of safety, economic efficiency, and availability of the German nuclear power plants. German NPPs occupy a top position in this respect at international level, but novel instrumentation and digital control technology alone will not guarantee further enhancements. Therefore, the owner/operators established carefully devised maintenance and modernization strategies in order to safeguard their NPPs top position in the long run. The German NPPs are the most thoroughly automated plants of the world. In addition to the sweeping modernization strategies recommended by the plant manufacturers, based on computer-supported control, alternative modernization strategies have been considered in the evaluation process. This approach provides for room for maneuvre, for manufacturers as well as managers responsible for risk and cost optimization, which is a major task in view of the changing regulatory framework in the electricity market. (orig./CB) [de

  11. Lymphoid Tissue Grafts in Man

    Energy Technology Data Exchange (ETDEWEB)

    Kay, H. E.M. [Royal Marsden Hospital, Institute of Cancer Research, London (United Kingdom)

    1969-07-15

    Grafts of lymphoid tissue or of lymphoid stem cells may be appropriate in the treatment of some congenital immune deficiency disorders. The reasons for preferring tissues of foetal origin are discussed and the evidence for foetal immunocompetence is briefly summarized. Methods of storing foetal liver cells and cells or fragments of thymus are mentioned, and the organization of the Foetal Tissue Bank of the Royal Marsden Hospital is described. Clinical data from transplantation of lymphoid cells in various immune deficiency disorders are briefly presented. (author)

  12. Live insertion method used for main renewal

    International Nuclear Information System (INIS)

    Solkowitz, M.

    1992-01-01

    Baltimore Gas and Electric's pilot project using the live insertion method to replace a cast iron main provided excellent results. Its use on Eastern Avenue, a major state highway, was cost effective, provided gas service to customers during the work, required relatively short construction time and resulted in only minor traffic disruptions. Gas service transfers to the new main were done at customer convenience and resulted in outages of only a few hours per customer. This paper reports that the project involved inserting a 6-in. plastic line inside an existing 10-in. cast iron main. Miller Pipeline Corp., Indianapolis, supplier of the Insertec left-angle R right-angle live insertion method was contracted for the job. Miller technicians assisted BG and E forces by providing a load analysis of the main, a pushing machine and related supplies, foaming equipment and pipe cutting tools. Company forces were responsible for all preparatory work, including opening all excavations, installing bypasses, and fusing and testing the plastic pipe. Service transfers and renewals were also completed by company employees

  13. App-assisted external ventricular drain insertion.

    Science.gov (United States)

    Eftekhar, Behzad

    2016-09-01

    The freehand technique for insertion of an external ventricular drain (EVD) is based on fixed anatomical landmarks and does not take individual variations into consideration. A patient-tailored approach based on augmented-reality techniques using devices such as smartphones can address this shortcoming. The Sina neurosurgical assist (Sina) is an Android mobile device application (app) that was designed and developed to be used as a simple intraoperative neurosurgical planning aid. It overlaps the patient's images from previously performed CT or MRI studies on the image seen through the device camera. The device is held by an assistant who aligns the images and provides information about the relative position of the target and EVD to the surgeon who is performing EVD insertion. This app can be used to provide guidance and continuous monitoring during EVD placement. The author describes the technique of Sina-assisted EVD insertion into the frontal horn of the lateral ventricle and reports on its clinical application in 5 cases as well as the results of ex vivo studies of ease of use and precision. The technique has potential for further development and use with other augmented-reality devices.

  14. Primary implant stability in augmented sinuslift-sites after completed bone regeneration: a randomized controlled clinical study comparing four subantrally inserted biomaterials.

    Science.gov (United States)

    Troedhan, Angelo; Schlichting, Izabela; Kurrek, Andreas; Wainwright, Marcel

    2014-07-30

    Implant-Insertion-Torque-Value (ITV) proved to be a significant clinical parameter to predict long term implant success-rates and to decide upon immediate loading. The study evaluated ITVs, when four different and commonly used biomaterials were used in sinuslift-procedures compared to natural subantral bone in two-stage-implant-procedures. The tHUCSL-INTRALIFT-method was chosen for sinuslifting in 155 sinuslift-sites for its minimal invasive transcrestal approach and scalable augmentation volume. Four different biomaterials were inserted randomly (easy-graft CRYSTAL n = 38, easy-graft CLASSIC n = 41, NanoBone n = 42, BioOss n = 34), 2 ccm in each case. After a mean healing period of 8,92 months uniform tapered screw Q2-implants were inserted and Drill-Torque-Values (DTV) and ITV were recorded and compared to a group of 36 subantral sites without need of sinuslifting. DTV/ITV were processed for statistics by ANOVA-tests. Mean DTV/ITV obtained in Ncm were: Control Group 10,2/22,2, Bio-Oss 12,7/26,2, NanoBone 17,5/33,3, easy-graft CLASSIC 20,3/45,9, easy-graft CRYSTAL 23,8/56,6 Ncm, significance-level of differences throughout p < 0,05. Within the limits of this study the results suggest self-hardening solid-block-like bone-graft-materials to achieve significantly better DTV/ITV than loose granulate biomaterials for its suspected improvement of vascularization and mineralization of the subantral scaffold by full immobilization of the augmentation site towards pressure changes in the human sinus at normal breathing.

  15. Bone response to collagenized xenografts of porcine origin (mp3(®) ) and a bovine bone mineral grafting (4BONE(™) XBM) grafts in tibia defects: experimental study in rabbits.

    Science.gov (United States)

    Calvo-Guirado, José Luis; Aguilar-Salvatierra, Antonio; Ramírez-Fernández, Maria P; Maté Sánchez de Val, José E; Delgado-Ruiz, Rafael Arcesio; Gómez-Moreno, Gerardo

    2016-08-01

    This study aimed to carry out the evaluation of bone response of new bone formation to two different xenografts (bovine and porcine) biomaterials inserted in rabbit tibiae. The study used a total of 20 male New Zealand albino rabbits. They received a total of 40 grafts in the proximal metaphyseal areas of both tibiae. Two biomaterials were evaluated: 20 porcine xenografts, as a bone granulate (OsteoBiol(®) MP3(®) ; Tecnoss srl, Giaveno, Italy), were placed in the proximal metaphyseal area of the right tibia, 20 anorganic bovine bone mineral grafting (4BONE(™) XBM, MIS Implants Inc., BARLEV, Israel) were placed in the left tibia. Following graft insertion, the animals were sacrificed in two groups of 10 animals, after 1 and 4 months, respectively. For each group, biomaterials were analyzed: newly formed bone, residual graft materials and the connective tissue. Histomorphometric, EDX analysis and element mapping were performed at 1 and 4 months after graft insertion. At 4 months after treatment, the bone defects displayed radiological images that showed complete repair of osseous defects. Histomorphometric evaluation showed that for the porcine xenograft, the study averages for newly formed bone represented 84.23 ± 2.9%, while bovine matrix was 79.34 ± 2.1%. For residual graft material, the porcine biomaterial had 11.23 ± 1.7% and the bovine graft 31.56 ± 2.3%. Finally, the connective tissue for MP3 was 10.33 ± 1.8%, while for the 4BONE(™) XBM we obtained 14.34 ± 2.9%. Element analysis revealed higher percentages of Ca (54 ± 9%) and P (35 ± 6%) in the group B than group A and control group (P MP3 material; this supports new bone formation, creates a bridge between borders, and facilitates bone ingrowth in both biomaterials. Furthermore, this study observed partial dissolution of the mineral phase of four bone graft and complete resorption of porcine MP3 biomaterial and its incorporation into the surrounding bone. Depending on

  16. Development of sodium alginate and konkoli gum- grafted ...

    African Journals Online (AJOL)

    STORAGESEVER

    2008-05-02

    May 2, 2008 ... grafted-polyacrylamide blend membrane: optimization of grafting conditions .... medium and reduce rate of termination by the coupling of the growing ... Effect of time. The time conversion curve of the graft copolymerization ...

  17. Industrial application of electron beams for grafting and vulcanization

    Energy Technology Data Exchange (ETDEWEB)

    Makuuchi, Keizo [Japan Atomic Energy Research Inst., Takasaki, Gunma (Japan). Takasaki Radiation Chemistry Research Establishment

    1994-12-31

    The topics discussed are radiation graft polymerization; industrial application of radiation grafting - ion exchange membrane for a battery separator, ammonia adsorbent, non-flammable PE (polyethylene) foam; R and D on radiation grafting, radiation vulcanization of natural rubber.

  18. Industrial application of electron beams for grafting and vulcanization

    International Nuclear Information System (INIS)

    Keizo Makuuchi

    1994-01-01

    The topics discussed are radiation graft polymerization; industrial application of radiation grafting - ion exchange membrane for a battery separator, ammonia adsorbent, non-flammable PE (polyethylene) foam; R and D on radiation grafting, radiation vulcanization of natural rubber

  19. Effect of bidispersity in grafted chain length on grafted chain conformations and potential of mean force between polymer grafted nanoparticles in a homopolymer matrix.

    Science.gov (United States)

    Nair, Nitish; Wentzel, Nathaniel; Jayaraman, Arthi

    2011-05-21

    In efforts to produce polymeric materials with tailored physical properties, significant interest has grown around the ability to control the spatial organization of nanoparticles in polymer nanocomposites. One way to achieve controlled particle arrangement is by grafting the nanoparticle surface with polymers that are compatible with the matrix, thus manipulating the interfacial interactions between the nanoparticles and the polymer matrix. Previous work has shown that the molecular weight of the grafted polymer, both at high grafting density and low grafting density, plays a key role in dictating the effective inter-particle interactions in a polymer matrix. At high grafting density nanoparticles disperse (aggregate) if the graft molecular weight is higher (lower) than the matrix molecular weight. At low grafting density the longer grafts can better shield the nanoparticle surface from direct particle-particle contacts than the shorter grafts and lead to the dispersion of the grafted particles in the matrix. Despite the importance of graft molecular weight, and evidence of non-trivial effects of polydispersity of chains grafted on flat surfaces, most theoretical work on polymer grafted nanoparticles has only focused on monodisperse grafted chains. In this paper, we focus on how bidispersity in grafted chain lengths affects the grafted chain conformations and inter-particle interactions in an implicit solvent and in a dense homopolymer polymer matrix. We first present the effects of bidispersity on grafted chain conformations in a single polymer grafted particle using purely Monte Carlo (MC) simulations. This is followed by calculations of the potential of mean force (PMF) between two grafted particles in a polymer matrix using a self-consistent Polymer Reference Interaction Site Model theory-Monte Carlo simulation approach. Monte Carlo simulations of a single polymer grafted particle in an implicit solvent show that in the bidisperse polymer grafted particles

  20. Onlay Rib Bone Graft in Elevation of Reconstructed Auricle: 17 Years of Experience

    Directory of Open Access Journals (Sweden)

    Taehoon Kim

    2013-05-01

    Full Text Available BackgroundA cartilage wedge block and covering flap are standard procedures for firm elevation of the ear in microtia correction. However, using costal cartilage for elevation of the reconstructed auricle can be insufficient, and the fixed cartilage wedge block may be absorbed or may slip out. Furthermore, elevating covering flaps is time-consuming and uses up fascia, a potential source of reconstruction material. Therefore, we propose an innovative method using autologous onlay rib bone graft for auricular elevation of microtia.MethodsFrom February 1995 to August 2012, 77 patients received a first stage operation with a rib cartilage framework graft. In the second stage operation, a small full thickness of rib bone was harvested through the previous donor scar. The bihalved rib bone was inserted into the subperiosteal pocket beneath the cartilage framework.ResultsThe follow-up time ranged from 1 month to 17 years, with a mean of 3 years. All of the patients sustained the elevation of their ears very well during the follow-up period. Donor site problems, except for hypertrophic scars, were not observed. Surgery-related complications, specifically skin necrosis, infection, or hematoma, occurred in 4 cases.ConclusionsOnlay rib bone graft used to elevate the reconstructed auricle is a more anatomically appropriate material than cartilage, due to the bone-to-bone contact between the bone graft and the temporal bone. Postoperative minor correction of the elevation degree is straightforward and the skin graft survives better. Therefore, reconstructed auricle elevation using onlay rib bone graft is a useful and valuable method.

  1. Liminality and the Modern

    DEFF Research Database (Denmark)

    Thomassen, Bjørn

    of the liquid structures of modern society. Shedding new light on a concept central to social thought, as well as its capacity for pushing social and political theory in new directions, this book will be of interest to scholars across the social sciences and philosophy working in fields such as social......-for-granted order of the world ceases to exist and novel forms emerge, often in unpredictable ways. Liminality and the Modern offers a comprehensive introduction to this concept, discussing its development and laying out a conceptual and experiential framework for thinking about change in terms of liminality...

  2. Introduction to modern physics

    International Nuclear Information System (INIS)

    Pfeffer, J.; Nir, S.

    1993-01-01

    The modern physics and its uses changed our world of concepts and ways of life. This book explains the basics of modern physics in a simple and extensive form. The main subjects included in the book are: The relativistic theory, quantum theory, the structure of the atom, the interaction of radiation with matter and nuclear physics. The book elaborates on some advanced subjects: The laser, Moessbauer effect, Nuclear magnetic Resonance and solids electric conductivity. The book is for natural sciences students, whose main subject is not physics. The book can be used also in high schools. (authors)

  3. Modern electronic maintenance principles

    CERN Document Server

    Garland, DJ

    2013-01-01

    Modern Electronic Maintenance Principles reviews the principles of maintaining modern, complex electronic equipment, with emphasis on preventive and corrective maintenance. Unfamiliar subjects such as the half-split method of fault location, functional diagrams, and fault finding guides are explained. This book consists of 12 chapters and begins by stressing the need for maintenance principles and discussing the problem of complexity as well as the requirements for a maintenance technician. The next chapter deals with the connection between reliability and maintenance and defines the terms fai

  4. Det sentimentalt moderne

    DEFF Research Database (Denmark)

    Thule Kristensen, Peter

    2005-01-01

    Romantikken er blevet afskrevet som en mørk epoke, hvor en hang til mystik og tvetydighed ikke passer til det moderne oplysningsprojekts mål om klarhed og orden. Afhendlingen viser imidlertid, hvordan dele af arkitekturen i det 20. århundrede er fyldt med romantisk tankegods, og hvordan romantisk...... nøglemotiver som f.eks. fragment, arabesk, krystal, symbol eller poesi kan bruges i en analyse - også af moderne arkitektur. det ses i bogens nyfortolkninger af værker og teorier hos arkitekterne Erik Gunnar Asplund, Josef Frank, Rudolf Schwarz, Aldo Rossi og Daniel Libeskind...

  5. Modern recording techniques

    CERN Document Server

    Huber, David Miles

    2013-01-01

    As the most popular and authoritative guide to recording Modern Recording Techniques provides everything you need to master the tools and day to day practice of music recording and production. From room acoustics and running a session to mic placement and designing a studio Modern Recording Techniques will give you a really good grounding in the theory and industry practice. Expanded to include the latest digital audio technology the 7th edition now includes sections on podcasting, new surround sound formats and HD and audio.If you are just starting out or looking for a step up

  6. BARCELONA: URBANSCAPES OF MODERNITY

    Directory of Open Access Journals (Sweden)

    Antoni Remesar

    2015-04-01

    The Do.Co.Mo.Mo’s. database, referring to Barcelona, lists 34 buildings that could be classified as rationalists and / or modern. According to other sources, we could reach fifty constructed buildings between the late 1920s and the end of the war in Spain. The article presents the results of a field work that, using different sources, has tried to to order and record the architectural production that can be considered modern / rationalist in Barcelona in the 1920s and 1930s

  7. Modern physics for engineers

    CERN Document Server

    Singh, Jasprit

    1999-01-01

    Linking physics fundamentals to modern technology-a highly applied primer for students and engineersReminding us that modern inventions-new materials, information technologies, medical technological breakthroughs-are based on well-established fundamental principles of physics, Jasprit Singh integrates important topics from quantum mechanics, statistical thermodynamics, and materials science, as well as the special theory of relativity. He then goes a step farther and applies these fundamentals to the workings of electronic devices-an essential leap for anyone interested in developing n

  8. Improvement of polymer stability by radiation grafting

    International Nuclear Information System (INIS)

    Ranogajec, F.; Mlinac-Misak, M.

    1999-01-01

    Losses of the stabilizer due to extractability or volatility immediately affect ultimate performance of polymer product. A new approach to increase the persistence of the stabilizer in the final product is to chemically bind it to the polymer backbone. Radiation grafting or crosslinking could be an efficient method for this, when the stabilizer is polymerizable. By a mutual gamma irradiation method, photoprotector 2-hydroxy-4-(3-methacryloxy-2- hydroxy-propoxy) benzophenone (HMB) has been readily grafted to low density polyethylene (LDPE) in benzene, tetrahydrofuran and methanol solution, respectively. Surface grafting occurs in a methanol solution of stabilizer, while in benzene and tetrahydrofuran solutions of stabilizer, grafting proceeds more or less in the inner parts of the polymeric film as well. The grafted LDPE film in methanol and tetrahydrofuran (containing 1 w/w % of grafted HMB), 1 w/w % blended HMB with LDPE and nongrafted LDPE film, were all exposed to accelerated aging and natural weathering and their spectral changes, expressed by the carbonyl index, were then compared. The change of elongation at break and tensile strength were measured in the course of aging. UV stability tests on aged films and change in mechanical properties indicate a pronounced protective effect achieved by grafted stabilizer. Grafting in methanol solution appears to be an efficient photostabilization treatment and the most economical with respect to the consumption of monomer, the grafting yield being less than 0.5%. Surface grafting is an efficient photostabilization method since grafted stabilizer is chemically bound to a polymeric surface and in this way the problem of evaporation of blended stabilizers during the prolonged use of polymeric materials is eliminated. (author)

  9. Lower limb gigantism, lymphedema, and painful varicosities following a thigh vascular access graft.

    Science.gov (United States)

    Thompson, Michael; Mathuram Thiyagarajan, Umasankar; Akoh, Jacob A

    2014-07-01

    Prosthetic arteriovenous grafts (AVGs) are associated with greater morbidity than autogenous arteriovenous fistulas (AVFs), but their use is indicated when AVF formation is not possible. This report adds to the literature a case of lower limb gigantism, painful varicosities, and lymphedema following long-term use of AVG in the upper thigh. The patient's past medical history included renal transplantation on the same side well before the AVG was inserted and right leg deep vein thrombosis. Suspicion of AVG thrombosis was excluded by Doppler ultrasound, which demonstrated an access flow of 1700 mL/min. A computed tomography (CT) scan of the abdomen and pelvis did not identify the cause of her symptoms. Whereas functional incompetence of the iliac vein valve might be responsible for the varicosities, the extent of hypertrophy in this case raises the suspicion of lymphatic blockage possibly secondary to groin dissection undertaken at the time of graft insertion, in addition to the previous dissection at the time of transplantation. This case highlights the need for minimal groin dissection during AVG insertion, particularly in patients with a history of previous abdominopelvic surgery. © 2014 International Society for Hemodialysis.

  10. Biodegradability of poly(3-hydroxybutyrate) film grafted with vinyl acetate: Effect of grafting and saponification

    Science.gov (United States)

    Wada, Yuki; Seko, Noriaki; Nagasawa, Naotsugu; Tamada, Masao; Kasuya, Ken-ichi; Mitomo, Hiroshi

    2007-06-01

    Radiation-induced graft polymerization of vinyl acetate (VAc) onto poly(3-hydroxybutyrate) (PHB) film was carried out. At a degree of grafting higher than 5%, the grafted films (PHB-g-VAc) completely lost the enzymatic degradability that is characteristic of PHB due to the grafted VAc covering the surface of the PHB film. However, the biodegradability of the PHB-g-VAc films was recovered when the films were saponified in alkali solution under optimum conditions. Graft chains of the PHB-g-VAc film reacted selectively to become biodegradable polyvinyl alcohol (PVA). The biodegradability of the saponified PHB-g-VAc film increased rapidly with time.

  11. Biodegradability of poly(3-hydroxybutyrate) film grafted with vinyl acetate: Effect of grafting and saponification

    International Nuclear Information System (INIS)

    Wada, Yuki; Seko, Noriaki; Nagasawa, Naotsugu; Tamada, Masao; Kasuya, Ken-ichi; Mitomo, Hiroshi

    2007-01-01

    Radiation-induced graft polymerization of vinyl acetate (VAc) onto poly(3-hydroxybutyrate) (PHB) film was carried out. At a degree of grafting higher than 5%, the grafted films (PHB-g-VAc) completely lost the enzymatic degradability that is characteristic of PHB due to the grafted VAc covering the surface of the PHB film. However, the biodegradability of the PHB-g-VAc films was recovered when the films were saponified in alkali solution under optimum conditions. Graft chains of the PHB-g-VAc film reacted selectively to become biodegradable polyvinyl alcohol (PVA). The biodegradability of the saponified PHB-g-VAc film increased rapidly with time

  12. Nanofat grafting under a split-thickness skin graft for problematic wound management.

    Science.gov (United States)

    Kemaloğlu, Cemal Alper

    2016-01-01

    Obesity and certain medical disorders make the reconstruction of skin defects challenging. Different kind of procedure can be used for these defect, besides, skin grafting is one of the most common and simplest procedure. Fat grafting and stem cells which are located in the adipose tissue have been commonly used in plastic surgery for regeneration and rejuvenation purposes. To decrease graft failure rate we performed nanofat grafting under an autologous split-thickness skin graft in our patient who had a problematic wound. The case of a 35-year-old female patient with a traumatic skin defect on her left anterior crural region is described herein. After subsequent flap reconstruction, the result was disappointing and the defect size was widened. The defect was treated with combined grafting (nanofat grafting under an autologous split-thickness skin graft). At the 6 months follow-up assessment after combined grafting, the integrity of the skin graft was good with excellent pliability. Combined grafting for problematic wounds seems to be a useful technique for cases requiring reconstruction. The potential existence of stem cells may be responsible for the successful result in our patient.

  13. Penetrating Atherosclerotic Ulcer of the Descending Thoracic Aorta: Treatment by Endovascular Stent-Graft

    International Nuclear Information System (INIS)

    Murgo, Salvatore; Dussaussois, Luc; Golzarian, Jafar; Cavenaile, Jean Christophe; Abada, Hicham Tarik; Ferreira, Jose; Struyven, Julien

    1998-01-01

    Purpose: To present four cases of penetrating ulcer of the descending thoracic aorta treated by transfemoral insertion of an endoluminal stent-graft. Methods: Four patients with penetrating aortic ulcers were reviewed. Three cases were complicated by rupture, false aneurysm, or retrograde dissection. All patients were treated by endovascular stent-graft and were followed by helical computed tomography (CT). Results: Endovascular stent-graft deployment was successful in all patients. However, in one case we observed a perigraft leak that spontaneously disappeared within the first month, and two interventions were needed for another patient. Following treatment, one episode of transient spinal ischemia was observed. The 30-day survival rate was 100%, but one patient died from pneumonia with cardiac failure 34 days after the procedure. In one patient, helical CT performed at 3 months showed a false aneurysm independent of the first ulcer. This patient refused any further treatment and suddenly died at home (unknown cause) after a 6-month follow-up period. Conclusion: Transluminal placement of endovascular stent-grafts for treatment of penetrating ulcers of the descending thoracic aorta appears to be a possible alternative to classical surgery. After treatment, follow-up by CT is essential to detect possible complications of the disease

  14. Potassium fulvate as co-interpenetrating agent during graft polymerization of acrylic acid from cellulose.

    Science.gov (United States)

    Ghazy, Mohamed B M; El-Hai, Farag Abd; Mohamed, Magdy F; Essawy, Hisham A

    2016-10-01

    Grafting polymerization of acrylic acid onto cellulose in presence of potassium fulvate (KF) as a co-interpenetrating agent results enhanced water sorption compared to materials prepared similarly in its absence. The insertion of potassium fulvate (KF) did not affect the grafting process and is thought to proceed in parallel to the graft polymerization via intensive polycondensation reactions of its function groups (-COOH and OH) with COOH of the monomer and OH groups of cellulose. The combination of graft copolymerization and polycondensation reactions is assumed to produce interpenetrating network structure. Fourier transform infrared (FTIR) confirmed successful incorporation within the network structure which is an evidence for formation of interpenetrating network. The obtained structures showed homogeneous uniform surface as revealed by scanning electron microscopy (SEM). The obtained superabsorbent possessed high water absorbency 422 and 48.8g/g in distilled water and saline (0.9wt.% NaCl solution), respectively, and enhanced water retention even at elevated temperatures as revealed by thermogravimetric analysis (TGA). This could be explained by the high content of hydrophilic groups. The new superabsorbents proved to be efficient devices for controlled release of fertilizers which expands their use in agricultural applications. Copyright © 2016 Elsevier B.V. All rights reserved.

  15. Grafting of Styrene onto Commercial Polytetrafluorethylene (PTFE) Membrane and Sulfonation for Possible use in Fuel Cell

    International Nuclear Information System (INIS)

    Abdel-Hady, E.E.; Abdel-Hamed, M.O.; Hammam, A.M.; El-toony, M.M.

    2010-01-01

    The purpose of this work is to initiate the fundamental research necessary for the development of a novel proton-exchange membranes (PEM) to overcome the material and performance limitations of the s tate of the art N afion that is used in both hydrogen and methanol fuel cells. Silica was inserted in commercial PTFE membrane in ratio 8%. Gamma irradiation was used for grafting of different ratios of styrene onto the membrane in one and two steps. Methacrylic acid and styrene were used as binary monomers for grafting of such membranes to raise the grafting percentage. Thermal characterization of the grafted membrane was discussed using thermal gravimetric analysis (TGA). The mechanical properties were tested by measuring ultimate tensile value, and Young modulus. The positron annihilation lifetime spectroscopy has been used to investigate the free volume hole size, while the surface morphology of the membrane was studied by scanning electron microscope (SEM). It was found that the maximum water uptake of the sulfonated membrane reached 20% by weight. The proton conductivity of the prepared polymer electrolyte was measured by ac impedance spectroscopic analysis. And it was found to be 0.9 x 10 -4 ohm -1 cm -1 .

  16. Emerging concepts in liver graft preservation

    Science.gov (United States)

    Bejaoui, Mohamed; Pantazi, Eirini; Folch-Puy, Emma; Baptista, Pedro M; García-Gil, Agustín; Adam, René; Roselló-Catafau, Joan

    2015-01-01

    The urgent need to expand the donor pool in order to attend to the growing demand for liver transplantation has obliged physicians to consider the use of suboptimal liver grafts and also to redefine the preservation strategies. This review examines the different methods of liver graft preservation, focusing on the latest advances in both static cold storage and machine perfusion (MP). The new strategies for static cold storage are mainly designed to increase the fatty liver graft preservation via the supplementation of commercial organ preservation solutions with additives. In this paper we stress the importance of carrying out effective graft washout after static cold preservation, and present a detailed discussion of the future perspectives for dynamic graft preservation using MP at different temperatures (hypothermia at 4 °C, normothermia at 37 °C and subnormothermia at 20 °C-25 °C). Finally, we highlight some emerging applications of regenerative medicine in liver graft preservation. In conclusion, this review discusses the “state of the art” and future perspectives in static and dynamic liver graft preservation in order to improve graft viability. PMID:25593455

  17. Dynamics of solvent-free grafted nanoparticles

    KAUST Repository

    Chremos, Alexandros; Panagiotopoulos, Athanassios Z.; Koch, Donald L.

    2012-01-01

    as well as grafted nanoparticles in a melt were compared to a reference system of bare (ungrafted) particles in a melt. Whereas longer chains lead to a larger hydrodynamic radius and lower relative diffusivity for grafted particles in a melt, bulk solvent

  18. Modern Fortran in practice

    NARCIS (Netherlands)

    Markus, A.

    2012-01-01

    From its earliest days, the Fortran programming language has been designed with computing efficiency in mind. The latest standard, Fortran 2008, incorporates a host of modern features, including object-orientation, array operations, user-defined types, and provisions for parallel computing. This

  19. Modern Versus Traditional Mathematics

    Science.gov (United States)

    Roberts, A. M.

    1974-01-01

    The effect of different secondary school mathematics syllabi on first-year performance in college-level mathematics was studied in an attempt to evaluate the syllabus change. Students with a modern mathematics background performed sigficantly better on most first-year units. A topic-by-topic analysis of results is included. (DT)

  20. Late-modern hipsters

    DEFF Research Database (Denmark)

    Andersen, Bjørn Schiermer

    2014-01-01

    The article deals with the cultural significance of a new figure in late-modern Western culture: the hipster. The current hipster culture, so I argue, can be used as a magnifying glass that makes impending changes to our conception of culture and of cultural development visible. It ushers...

  1. Dimensions of Modern Federalism.

    Science.gov (United States)

    Williams, Robert F.; And Others

    1995-01-01

    Encapsulates a series of brief essays exploring different aspects of modern federalism. Issues include further protection of individual rights extended through state constitutions and federalism and the world economy. Authors include Robert F. Williams, Earl H. Fry, and Daniel J. Elazar. (MJP)

  2. Landau and modern physics

    International Nuclear Information System (INIS)

    Pokrovsky, Valery L

    2009-01-01

    This article describes the history of the creation and further development of Landau's famous works on phase transitions, diamagnetism of electron gas (Landau levels), and quantum transitions at a level crossing (the Landau-Zener phenomenon), and its role in modern physics. (methodological notes)

  3. Meta Modernism: An Introduction

    Science.gov (United States)

    Snell, Joel

    2016-01-01

    The author introduces Hegel. From the triad (Hegelian Dialect), he briefly gives an overview of the history of philosophy. In true Hegelian form, it is now time to reform "Postmodernism" and replace it with "Meta modernism." Postmodern had a short life from 1950 to now and has left few adherents. It is confusing and…

  4. Modern vs. Traditional.

    Science.gov (United States)

    Zhenhui, Rao

    1999-01-01

    This article discusses traditional methods, such as the grammar-translation, and modern methods, the communicative approach, for teaching English-as-a-foreign-language in China. The relationship between linguistic accuracy and communicative competence, student-centered orientation, and the role of the teacher are highlighted. (Author/VWL)

  5. Den moderne bevidstheds katedral

    DEFF Research Database (Denmark)

    Ostenfeld Pedersen, Simon

    2002-01-01

    Interview med idéhistorikeren Dorthe Jørgensen der under overskriften ”Den moderne bevidstheds katedral” blotlægger hendes mangeårige arbejde med Hegel, og hvor hun giver en række relevante bud på en aktualiserende Hegel-læsning centreret omkring felter som metafysik, historiefilosofi og æstetik....

  6. Euripides in Modern Europe

    NARCIS (Netherlands)

    den Boer, P.

    2010-01-01

    Euripides is considered the most human, modern and existentialist of the famous Greek tragedians. Extremely popular after his death, he continued to be staged, read and much recited in Hellenistic and Roman times. As the Greek-speaking elite of the Roman Empire disappeared, the popularity of the

  7. A Modern Periodic Table.

    Science.gov (United States)

    Herrenden-Harker, B. D.

    1997-01-01

    Presents a modern Periodic Table based on the electron distribution in the outermost shell and the order of filling of the sublevels within the shells. Enables a student to read off directly the electronic configuration of the element and the order in which filling occurs. (JRH)

  8. Modern Reduction Methods

    CERN Document Server

    Andersson, Pher G

    2008-01-01

    With its comprehensive overview of modern reduction methods, this book features high quality contributions allowing readers to find reliable solutions quickly and easily. The monograph treats the reduction of carbonyles, alkenes, imines and alkynes, as well as reductive aminations and cross and heck couplings, before finishing off with sections on kinetic resolutions and hydrogenolysis. An indispensable lab companion for every chemist.

  9. The effect of monomer molecular weight on grafting reaction

    International Nuclear Information System (INIS)

    Wu Minghong; Ding Zhongli; Ma Zueteh

    1995-01-01

    In this paper, some condensed ethylene glycol acrylate monomers with different molecular weight being grafted to the PE film by means of pre-irradiation is reported. The effect of molecular weight of monomer on grafting reaction and the hydrophilicity of grafting sample have been discussed. The experimental results show: molar degrees of grafting decreased non-linearly with the increasement of molecular weight of monomer, the grafting reaction of polymer is greater effected by the swelling degree of PE film, the greater the swelling degree of grafting material, the higher the grating degree grafting is, the initial rate of grafting reaction decreased with the increasement of molecular weight of monomer. (author)

  10. Ahmed glaucoma valve implantation with tube insertion through the ciliary sulcus in pseudophakic/aphakic eyes.

    Science.gov (United States)

    Eslami, Yadolla; Mohammadi, Massood; Fakhraie, Ghasem; Zarei, Reza; Moghimi, Sasan

    2014-02-01

    To report the efficacy and safety of Ahmed glaucoma valve (AGV) insertion into the ciliary sulcus in pseudophakic/aphakic patients. A chart review was done on patients with uncontrolled glaucoma, who underwent AGV implantation with tube inserted into the ciliary sulcus. Baseline intraocular pressure (IOP) and number of medications were compared with that of postoperative follow-up visits. Surgical success was defined as last IOP glaucoma control, and without loss of light perception. Postoperative complications were recorded. Twenty-three eyes of 23 patients were recruited with the mean follow-up of 9 months (range, 3 to 24 mo). The mean (SD) age of patients was 49.9 (16.9) years (range, 22 to 80 years). The mean (SD) IOP (mm Hg) was reduced from 37.9 (12.4) before surgery to 16.2 (3.6) at the last follow-up visit (P<0.001). The mean (SD) number of medications was reduced from 3.3 (0.9) preoperatively to 1 (1.1) at the last follow-up (P<0.001). Success rate was 18/23 (78.6%). Complications included endophthalmitis in 1 eye, tube exposure in 1 diabetic patient, and vitreous tube occlusion in 1 eye. No case of corneal decompensation or graft failure was seen during follow-up. Ciliary sulcus placement of the tube of AGV effectively reduces IOP and medication use in short term. It has the potential to lower corneal complications of anterior chamber tube insertion and avoids the need for pars plana vitrectomy and tube insertion in patients at higher risk of corneal decompensation.

  11. Aluminum uptake from natural waters by a radiation-grafted membrane

    Energy Technology Data Exchange (ETDEWEB)

    Bazante-Yamaguishi, Renata; Moura, Eduardo; Manzoli, Jose E.; Geraldo, Aurea B.C., E-mail: ageraldo@ipen.br, E-mail: ryamaguishi@ipen.br [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil)

    2013-07-01

    Styrene grafted, chemically modified polymeric membranes were used to carry off aluminum of drinking water from wells located at Billings dam region. The membranes comprised polymeric substrates of PVC (polyvinylchloride) and PP (polypropylene), which were mutually grafted with gamma radiation. The chemical modification included three basic reaction paths: Friedel-Crafts acylation, 2-methylanisole coupling and a final oxidation; this modification enables aluminum selectivity on the membrane. This chemical process inserts a salicylated derivative bonded onto the aromatic ring of styrene; such molecular arrangement is responsible for complexation of aluminum ions. The aluminum sorption capacity of these membranes was evaluated firstly from an aluminum control solution, where parameters like the ideal pH value for aluminum sorption and the interfering species were studied and correlated to know the best conditions for aluminum uptake. Later, the membranes were used for aluminum remediation of natural waters (real-life samples). The applicability results and limits are then discussed. (author)

  12. Aluminum uptake from natural waters by a radiation-grafted membrane

    International Nuclear Information System (INIS)

    Bazante-Yamaguishi, Renata; Moura, Eduardo; Manzoli, Jose E.; Geraldo, Aurea B.C.

    2013-01-01

    Styrene grafted, chemically modified polymeric membranes were used to carry off aluminum of drinking water from wells located at Billings dam region. The membranes comprised polymeric substrates of PVC (polyvinylchloride) and PP (polypropylene), which were mutually grafted with gamma radiation. The chemical modification included three basic reaction paths: Friedel-Crafts acylation, 2-methylanisole coupling and a final oxidation; this modification enables aluminum selectivity on the membrane. This chemical process inserts a salicylated derivative bonded onto the aromatic ring of styrene; such molecular arrangement is responsible for complexation of aluminum ions. The aluminum sorption capacity of these membranes was evaluated firstly from an aluminum control solution, where parameters like the ideal pH value for aluminum sorption and the interfering species were studied and correlated to know the best conditions for aluminum uptake. Later, the membranes were used for aluminum remediation of natural waters (real-life samples). The applicability results and limits are then discussed. (author)

  13. Clinical results of arthroscopic polyglycolic acid sheet patch graft for irreparable rotator cuff tears

    Directory of Open Access Journals (Sweden)

    Yu Mochizuki

    2015-01-01

    Full Text Available The high retear rates after surgery for irreparable rotator cuff tears can be explained by the healing capacity potential of tendons and the native rotator cuff enthesis characterised by complex morphological structures, called direct insertion. Many experimental researches have focused on biologically augmenting the rotator cuff reconstruction and improving tendon–bone healing of the rotator cuff. The results of the experimental study showed that the polyglycolic acid sheet scaffold material allows for the regeneration of not only tendon-to-tendon, but also tendon-to-bone interface in an animal model. We performed a clinical study of the arthroscopic polyglycolic acid sheet patch graft used for the repair of irreparable rotator cuff tears. One-year clinical results of the repair of irreparable rotator cuff tears by arthroscopic patch graft with a polyglycolic acid sheet demonstrated improved shoulder function and a significantly lower retear rate, compared with patients treated with a fascia lata patch.

  14. Endovascular treatment of external iliac vein stenosis caused by graft compression after kidney transplantation

    Directory of Open Access Journals (Sweden)

    Willamax Oliveira de Sousa

    2013-06-01

    Full Text Available A 57-year old patient presented with approximately 80% stenosis of the left external iliac vein due to compression by the renal graft after kidney transplantation. The initial clinical manifestation of this vascular complication was progressive edema of the left lower limb, starting in the foot during the immediate postoperative period and reaching the thigh. Renal function also deteriorated during the first four months after transplantation. Venous Doppler ultrasound findings were suggestive of a diagnosis of extrinsic compression by the kidney graft and so phlebography was ordered, confirming stenosis of the left external iliac vein. The patient was initially treated with balloon angioplasty, but there was still residual stenosis so a stent was inserted, eliminating the stenosis. The edema reduced over time and the patient's renal function improved. While vascular complications are rare, and potentially severe, events, success rates are good if treatment is started early.

  15. Cadaveric aorta implantation for aortic graft infection.

    Science.gov (United States)

    Ali, Asad; Bahia, Sandeep S S; Ali, Tahir

    2016-01-01

    This case report describes a 73-year-old gentleman who underwent explantation of an infected prosthetic aorto-iliac graft and replacement with a cryopreserved thoracic and aorto-iliac allograft. The patient has been followed up a for more than a year after surgery and remains well. After elective tube graft repair of his abdominal aortic aneurysm (AAA) in 2003, he presented to our unit in 2012 in cardiac arrest as a result of a rupture of the distal graft suture line due to infection. After resuscitation he underwent aorto-bifemoral grafting using a cuff of the original aortic graft proximally. Distally the new graft was anastomosed to his common femoral arteries, with gentamicin beads left in situ. Post discharge the patient was kept under close surveillance with serial investigations including nuclear scanning, however it became apparent that his new graft was infected and that he would require aortic graft replacement, an operation with a mortality of at least 50%. The patient underwent the operation and findings confirmed a synthetic graft infection. This tube graft was explanted and a cryopreserved aorta was used to the refashion the abdominal aorta and its bifurcation. The operation required a return to theatre day one post operatively for a bleeding side branch, which was repaired. The patient went on to make a full recovery stepping down from the intensive therapy unit day 6 post operatively and went on to be discharged 32 days after his cryopreserved aorta implantation. Copyright © 2016 The Author(s). Published by Elsevier Ltd.. All rights reserved.

  16. Experimental testing of exchangeable cutting inserts cutting ability

    OpenAIRE

    Čep, Robert; Janásek, Adam; Čepová, Lenka; Petrů, Jana; Hlavatý, Ivo; Car, Zlatan; Hatala, Michal

    2013-01-01

    The article deals with experimental testing of the cutting ability of exchangeable cutting inserts. Eleven types of exchangeable cutting inserts from five different manufacturers were tested. The tested cutting inserts were of the same shape and were different especially in material and coating types. The main aim was both to select a suitable test for determination of the cutting ability of exchangeable cutting inserts and to design such testing procedure that could make it possible...

  17. Atomistic Galois insertions for flow sensitive integrity

    DEFF Research Database (Denmark)

    Nielson, Flemming; Nielson, Hanne Riis

    2017-01-01

    Several program verification techniques assist in showing that software adheres to the required security policies. Such policies may be sensitive to the flow of execution and the verification may be supported by combinations of type systems and Hoare logics. However, this requires user assistance...... and to obtain full automation we shall explore the over-approximating nature of static analysis. We demonstrate that the use of atomistic Galois insertions constitutes a stable framework in which to obtain sound and fully automatic enforcement of flow sensitive integrity. The framework is illustrated...

  18. Modern materials in fabrication of scaffolds for bone defect replacement

    Science.gov (United States)

    Bazlov, V. A.; Mamuladze, T. Z.; Pavlov, V. V.; Kirilova, I. A.; Sadovoy, M. A.

    2016-08-01

    The article defines the requirements for modern scaffold-forming materials and describes the main advantages and disadvantages of various synthetic materials. Osseointegration of synthetic scaffolds approved for use in medical practice is evaluated. Nylon 618 (certification ISO9001 1093-1-2009) is described as the most promising synthetic material used in medical practice. The authors briefly highlight the issues of individual bone grafting with the use of 3D printing technology. An example of contouring pelvis defect after removal of a giant tumor with the use of 3D models is provided.

  19. Enhancement of heat transfer using varying width twisted tape inserts

    African Journals Online (AJOL)

    user

    enhancement of heat transfer with twisted tape inserts as compared to plain ... studies for heat transfer and pressure drop of laminar flow in horizontal tubes ... flow in rectangular and square plain ducts and ducts with twisted-tape inserts .... presence of the insert in the pipe causes resistance to flow and increases turbulence.

  20. Imaging features of anterior cruciate ligament reconstruction graft insufficiency

    International Nuclear Information System (INIS)

    Shang Yao; Zhang Yue; Tian Chunyan; Zheng Zhuozhao

    2011-01-01

    Objective: To investigate the imaging features of anterior cruciate ligament (ACL) graft insufficiency. Methods: X-Ray and MR imaging examinations in 24 consecutive patients who had ACL reconstructive graft insufficiency were retrospectively evaluated for tunnel position, osteoarthrosis and its related complications. Follow-up arthroscopy showed 16 graft tears and 8 graft laxities. Fisher exact test was used to compare tunnel malpositions, the proportion of graft tear on MRI and osteoarthrosis between graft tear group and graft laxity group. Results: Two malpositions of tibial tunnel and 3 malpositions of femoral tunnel were seen in graft tear group. Three-malpositions of tibial tunnel and 4 malpositions of femoral tunnel were seen in graft laxity group. The proportion of tibial or femoral malposition showed no significant difference between the two groups (P=0.289, P=0.167). In graft tear group, 15 complete graft tears were diagnosed correctly, 1 partial tear was misdiagnosed as normal on MRI. In graft laxity group, 4 grafts were diagnosed as normal and 4 were considered as graft tear on MRI. A significant difference was seen between the two groups (P=0.028) in the proportion of graft tear diagnosed on MRI. Fourteen osteoarthrosis were seen in graft tear group and 5 in graft laxity group. No significant difference was seen between the two groups (P= 0.289) in the proportion of osteoarthrosis. Conclusion: The proportions of tunnel malposition and osteoarthrosis showed no significant difference between the graft tear group and graft Laxity group. Most graft tears can be diagnosed accurately on MRI, but some cases of graft laxity may be misdiagnosed for graft tear. (authors)

  1. Chloroanthraquinone as a grafted probe molecule to investigate grafting yield on carbon powder

    International Nuclear Information System (INIS)

    Le Comte, Annaïg; Brousse, Thierry; Bélanger, Daniel

    2016-01-01

    Spontaneous grafting of chloroanthraquinone (ClAQ) groups on Black Pearls carbon by reduction of the corresponding in-situ generated diazonium cations was successfully achieved. The presence of an halogen atom on the quinone molecule allowed the use of different spectroscopic characterization techniques to determine the accurate quinone content of the modified carbon. Electrochemical characterization highlighted that the presence of chlorine atom on the grafted molecule did not affect the electrochemical response or the grafting reaction efficiency. The amount of ClAQ molecules at the carbon surface after grafting was determined by cyclic voltammetry, together with thermogravimetric analysis coupled mass spectroscopy, X-ray photoelectron spectroscopy and elemental analysis. The ClAQ mass loadings estimated from the four techniques are in very good agreement and confirm that the grafted moieties are all electrochemically active and accessible. Finally, the grafting of quinone-type molecule using the reduction of diazonium cations does not affect the electroactivity of the grafted groups and cyclic voltammetry can be considered as a reliable technique to evaluate the mass loading of grafted quinone groups on porous carbon. Thus ClAQ can be used as a grafted probe molecule to investigate grafting yield on carbon powder, and this approach can be extended to functionalized electrodes used in an increasing number of electrochemical energy storage devices.

  2. Evaluation of synthetic vascular grafts in a mouse carotid grafting model.

    Directory of Open Access Journals (Sweden)

    Alex H P Chan

    Full Text Available Current animal models for the evaluation of synthetic grafts are lacking many of the molecular tools and transgenic studies available to other branches of biology. A mouse model of vascular grafting would allow for the study of molecular mechanisms of graft failure, including in the context of clinically relevant disease states. In this study, we comprehensively characterise a sutureless grafting model which facilitates the evaluation of synthetic grafts in the mouse carotid artery. Using conduits electrospun from polycaprolactone (PCL we show the gradual development of a significant neointima within 28 days, found to be greatest at the anastomoses. Histological analysis showed temporal increases in smooth muscle cell and collagen content within the neointima, demonstrating its maturation. Endothelialisation of the PCL grafts, assessed by scanning electron microscopy (SEM analysis and CD31 staining, was near complete within 28 days, together replicating two critical aspects of graft performance. To further demonstrate the potential of this mouse model, we used longitudinal non-invasive tracking of bone-marrow mononuclear cells from a transgenic mouse strain with a dual reporter construct encoding both luciferase and green fluorescent protein (GFP. This enabled characterisation of mononuclear cell homing and engraftment to PCL using bioluminescence imaging and histological staining over time (7, 14 and 28 days. We observed peak luminescence at 7 days post-graft implantation that persisted until sacrifice at 28 days. Collectively, we have established and characterised a high-throughput model of grafting that allows for the evaluation of key clinical drivers of graft performance.

  3. Evaluation of synthetic vascular grafts in a mouse carotid grafting model.

    Science.gov (United States)

    Chan, Alex H P; Tan, Richard P; Michael, Praveesuda L; Lee, Bob S L; Vanags, Laura Z; Ng, Martin K C; Bursill, Christina A; Wise, Steven G

    2017-01-01

    Current animal models for the evaluation of synthetic grafts are lacking many of the molecular tools and transgenic studies available to other branches of biology. A mouse model of vascular grafting would allow for the study of molecular mechanisms of graft failure, including in the context of clinically relevant disease states. In this study, we comprehensively characterise a sutureless grafting model which facilitates the evaluation of synthetic grafts in the mouse carotid artery. Using conduits electrospun from polycaprolactone (PCL) we show the gradual development of a significant neointima within 28 days, found to be greatest at the anastomoses. Histological analysis showed temporal increases in smooth muscle cell and collagen content within the neointima, demonstrating its maturation. Endothelialisation of the PCL grafts, assessed by scanning electron microscopy (SEM) analysis and CD31 staining, was near complete within 28 days, together replicating two critical aspects of graft performance. To further demonstrate the potential of this mouse model, we used longitudinal non-invasive tracking of bone-marrow mononuclear cells from a transgenic mouse strain with a dual reporter construct encoding both luciferase and green fluorescent protein (GFP). This enabled characterisation of mononuclear cell homing and engraftment to PCL using bioluminescence imaging and histological staining over time (7, 14 and 28 days). We observed peak luminescence at 7 days post-graft implantation that persisted until sacrifice at 28 days. Collectively, we have established and characterised a high-throughput model of grafting that allows for the evaluation of key clinical drivers of graft performance.

  4. Graft irradiation abrogates graft-versus-host disease in combined pancreas-spleen transplantation

    International Nuclear Information System (INIS)

    Schulak, J.A.; Sharp, W.J.

    1986-01-01

    A model of combined pancreas-spleen transplantation (PST) was studied in LBN F1 recipients of Lewis grafts in order to evaluate the efficacy of pretransplant graft irradiation in preventing lethal graft-versus-host disease (GVHD). Recipients of unmodified PST uniformly developed severe GVHD and died (MST = 16.7 +/- 3.8 days). Whole body donor irradiation with either 500 or 250 rad prevented lethal GVHD. Similarly, ex vivo graft irradiation with either 1000 or 500 rad also resulted in normal weight gain, graft function, and host survival for the 6-week study period. Conversely, delay of graft irradiation until 3 days after transplantation failed to prevent this complication (MST = 15.8 +/- 3.7 days). Recipients of irradiated grafts displayed glucose tolerance tests that were identical to those in the control group indicating that the doses of radiation employed in these experiments were not deleterious to islet function. Irradiated spleen grafts appeared histologically normal at 6 weeks after transplantation. Cells derived from these grafts failed to stimulate lymph node enlargement in a popliteal lymph node assay for GVHD, suggesting that these spleens may have become repopulated with host cells. These experiments confirm that PST has the potential to cause lethal GVHD and suggest that pretransplant graft irradiation may be used to prevent its occurrence

  5. Phase transitions modern applications

    CERN Document Server

    Gitterman, Moshe

    2014-01-01

    This book provides a comprehensive review of the theory of phase transitions and its modern applications, based on the five pillars of the modern theory of phase transitions i.e. the Ising model, mean field, scaling, renormalization group and universality. This expanded second edition includes, along with a description of vortices and high temperature superconductivity, a discussion of phase transitions in chemical reaction and moving systems. The book covers a close connection between phase transitions and small world phenomena as well as scale-free systems such as the stock market and the Internet. Readership: Scientists working in different fields of physics, chemistry, biology and economics as well as teaching material for undergraduate and graduate courses.

  6. Methods in Modern Biophysics

    CERN Document Server

    Nölting, Bengt

    2006-01-01

    Incorporating recent dramatic advances, this textbook presents a fresh and timely introduction to modern biophysical methods. An array of new, faster and higher-power biophysical methods now enables scientists to examine the mysteries of life at a molecular level. This innovative text surveys and explains the ten key biophysical methods, including those related to biophysical nanotechnology, scanning probe microscopy, X-ray crystallography, ion mobility spectrometry, mass spectrometry, proteomics, and protein folding and structure. Incorporating much information previously unavailable in tutorial form, Nölting employs worked examples and 267 illustrations to fully detail the techniques and their underlying mechanisms. Methods in Modern Biophysics is written for advanced undergraduate and graduate students, postdocs, researchers, lecturers and professors in biophysics, biochemistry and related fields. Special features in the 2nd edition: • Illustrates the high-resolution methods for ultrashort-living protei...

  7. Methods in Modern Biophysics

    CERN Document Server

    Nölting, Bengt

    2010-01-01

    Incorporating recent dramatic advances, this textbook presents a fresh and timely introduction to modern biophysical methods. An array of new, faster and higher-power biophysical methods now enables scientists to examine the mysteries of life at a molecular level. This innovative text surveys and explains the ten key biophysical methods, including those related to biophysical nanotechnology, scanning probe microscopy, X-ray crystallography, ion mobility spectrometry, mass spectrometry, proteomics, and protein folding and structure. Incorporating much information previously unavailable in tutorial form, Nölting employs worked examples and about 270 illustrations to fully detail the techniques and their underlying mechanisms. Methods in Modern Biophysics is written for advanced undergraduate and graduate students, postdocs, researchers, lecturers, and professors in biophysics, biochemistry and related fields. Special features in the 3rd edition: Introduces rapid partial protein ladder sequencing - an important...

  8. Modernization mixed with nationalism

    Directory of Open Access Journals (Sweden)

    Nikiforov Konstantin V.

    2014-01-01

    Full Text Available This essay reflects on a particular manner in which modernisation have taken place in the Balkans in modern history, from the 1878 Berlin Congress onwards. The Balkan countries faced twofold difficulties in their development: they had to overcome their backwardness stemming from the centuries of the Ottoman yoke and catch up with modern Western Europe, and resolve their numerous mutual territorial and political disputes. The latter task was especially difficult due to the constant interference in Balkan affairs on the part of Great Powers. This interference further aggravated nationalistic tensions between the Balkan states. The peculiar mixture of modernisation efforts and nationalism remains to this day when the entire region strives to join the European Union.

  9. Modern real analysis

    CERN Document Server

    Ziemer, William P

    2017-01-01

    This first year graduate text is a comprehensive resource in real analysis based on a modern treatment of measure and integration. Presented in a definitive and self-contained manner, it features a natural progression of concepts from simple to difficult. Several innovative topics are featured, including differentiation of measures, elements of Functional Analysis, the Riesz Representation Theorem, Schwartz distributions, the area formula, Sobolev functions and applications to harmonic functions. Together, the selection of topics forms a sound foundation in real analysis that is particularly suited to students going on to further study in partial differential equations. This second edition of Modern Real Analysis contains many substantial improvements, including the addition of problems for practicing techniques, and an entirely new section devoted to the relationship between Lebesgue and improper integrals. Aimed at graduate students with an understanding of advanced calculus, the text will also appeal to mo...

  10. Relativity in modern physics

    CERN Document Server

    Deruelle, Nathalie

    2018-01-01

    This comprehensive textbook on relativity integrates Newtonian physics, special relativity and general relativity into a single book that emphasizes the deep underlying principles common to them all, yet explains how they are applied in different ways in these three contexts. Newton's ideas about how to represent space and time, his laws of dynamics, and his theory of gravitation established the conceptual foundation from which modern physics developed. Book I in this volume offers undergraduates a modern view of Newtonian theory, emphasizing those aspects needed for understanding quantum and relativistic contemporary physics. In 1905, Albert Einstein proposed a novel representation of space and time, special relativity. Book II presents relativistic dynamics in inertial and accelerated frames, as well as a detailed overview of Maxwell's theory of electromagnetism. This provides undergraduate and graduate students with the background necessary for studying particle and accelerator physics, astrophysics and ...

  11. Modern particle physics

    CERN Document Server

    AUTHOR|(CDS)2079874

    2013-01-01

    Unique in its coverage of all aspects of modern particle physics, this textbook provides a clear connection between the theory and recent experimental results, including the discovery of the Higgs boson at CERN. It provides a comprehensive and self-contained description of the Standard Model of particle physics suitable for upper-level undergraduate students and graduate students studying experimental particle physics. Physical theory is introduced in a straightforward manner with full mathematical derivations throughout. Fully-worked examples enable students to link the mathematical theory to results from modern particle physics experiments. End-of-chapter exercises, graded by difficulty, provide students with a deeper understanding of the subject. Online resources available at www.cambridge.org/MPP feature password-protected fully-worked solutions to problems for instructors, numerical solutions and hints to the problems for students and PowerPoint slides and JPEGs of figures from the book

  12. Modern operating systems

    CERN Document Server

    Tanenbaum, Andrew S

    2015-01-01

    Modern Operating Systems, Fourth Edition, is intended for introductory courses in Operating Systems in Computer Science, Computer Engineering, and Electrical Engineering programs. It also serves as a useful reference for OS professionals ' The widely anticipated revision of this worldwide best-seller incorporates the latest developments in operating systems (OS) technologies. The Fourth Edition includes up-to-date materials on relevant'OS. Tanenbaum also provides information on current research based on his experience as an operating systems researcher. ' Modern Operating Systems, Third Editionwas the recipient of the 2010 McGuffey Longevity Award. The McGuffey Longevity Award recognizes textbooks whose excellence has been demonstrated over time.'http://taaonline.net/index.html " Teaching and Learning Experience This program will provide a better teaching and learning experience-for you and your students. It will help: ' *Provide Practical Detail on the Big Picture Concepts: A clear and entertaining writing s...

  13. Modern water resources engineering

    CERN Document Server

    Yang, Chih

    2014-01-01

    The Handbook of Environmental Engineering series is an incredible collection of methodologies that study the effects of pollution and waste in their three basic forms: gas, solid, and liquid. This exciting new addition to the series, Volume 15: Modern Water Resources Engineering , has been designed to serve as a water resources engineering reference book as well as a supplemental textbook. We hope and expect it will prove of equal high value to advanced undergraduate and graduate students, to designers of water resources systems, and to scientists and researchers. A critical volume in the Handbook of Environmental Engineering series, chapters employ methods of practical design and calculation illustrated by numerical examples, include pertinent cost data whenever possible, and explore in great detail the fundamental principles of the field. Volume 15: Modern Water Resources Engineering, provides information on some of the most innovative and ground-breaking advances in the field today from a panel of esteemed...

  14. Technical aspects of preservation of architectural heritage of Modern in Serbia

    OpenAIRE

    Kuzović Duško

    2016-01-01

    This paper analyzes the technical and technological problems of preserving architecture from the period 1945-1990. Complex social and economic conditions hinder the proper approach to the preservation of Modernist architecture. Modern functions that are inserted into objects of Modern require complex changes to the building. If changes are not made in accordance with the principles of profession risk to completely lose the architectural value of the buildings. It is necessary to specify the t...

  15. The treatment of malignant ventricular tachycardia by aorto-coronary saphenous vein bypass graft

    Science.gov (United States)

    Ikram, H.; Jeffery, R. M.; Parkins, R. A.; Makey, A. R.; Emery, E. R. J.; Stone, D. L.

    1974-01-01

    A 61-year-old man with a previous cardiac infarction had at least fifteen attacks of ventricular tachycardia which finally did not respond to either drug or electrical therapy. Angiography showed a blocked right coronary artery and a non-contractile portion of postero-inferior left ventricular wall. An aorto to right coronary saphenous vein bypass graft was inserted, and although attacks of tachycardia occurred following the operation these were of short duration and reverted spontaneously. He has been free of tachycardia for 5 weeks, with a greatly improved effort tolerance. ImagesFig. 2Fig. 3

  16. Cobol software modernization

    CERN Document Server

    Barbier, Franck

    2015-01-01

    Nowadays, billions of lines of code are in the COBOL programming language. This book is an analysis, a diagnosis, a strategy, a MDD method and a tool to transform legacy COBOL into modernized applications that comply with Internet computing, Service-Oriented Architecture (SOA) and the Cloud.  It serves as a blueprint for those in charge of finding solutions to this considerable challenge.

  17. Modern optical science

    International Nuclear Information System (INIS)

    2001-05-01

    This book deals with modern optical science, which gives description of properties of light and transmission, ray tracing like Gaussian image, ray tracing and optical system, properties about light wave, a vector properties of light, interference and an interferometer, transform and application of interferometer, diffraction, application on diffraction, solid optical science, measurement of light and laser such as basic principle of laser, kinds of laser, pulse laser, resonator and single mode and multimode.

  18. Designing Modern Equity Portfolios

    OpenAIRE

    Ronald Jean Degen

    2011-01-01

    This aim of this paper is to describe possible ways of investing in equity; choosing the right stocks(among small-cap, large-cap, value, growth, and foreign) using fundamental analysis, defining their appropriate mix in the portfolios according to the desired return-risk profiles based on Markowitz?s modern portfolio theory, and using technical analysis to buy and sell them.

  19. Modern Human Capital Management

    OpenAIRE

    Feldberger, Madita

    2008-01-01

    Title: Modern Human Capital Management Seminar date: 30th of May 2008 Course: Master thesis in Business Administration, 15 ECTS Authors: Madita Feldberger Supervisor: Lars Svensson Keywords: Human capital, SWOT Analysis, Strategic Map, Balanced Scorecard Research Problem: Despite of the success of Human Capital Management (HCM) in research it did not arrive yet in the HR departments of many companies. Numerous firms even have problems to set their strategic goals with focus on HR. The HR Bala...

  20. 1998 Army Modernization Plan

    Science.gov (United States)

    1998-01-01

    Biological (CB) Protective Duty Uniform (STO) • Biometrics (SRO) • Nanoscience (SRO) • Millimeter Wave Material and Dissemination Technology... Biometrics and Nanoscience SROs will enable the development of advanced NBC detection and characterization systems, including the exploitation of biologically...Requirements Trailers • Procure HEMAT Trailers Figure K-23 K-19 //;<?. U.S. Army 1997Modernization Plan This final fleet assessment, made against the

  1. Modern electronic materials

    CERN Document Server

    Watkins, John B

    2013-01-01

    Modern Electronic Materials focuses on the development of electronic components. The book first discusses the history of electronic components, including early developments up to 1900, developments up to World War II, post-war developments, and a comparison of present microelectric techniques. The text takes a look at resistive materials. Topics include resistor requirements, basic properties, evaporated film resistors, thick film resistors, and special resistors. The text examines dielectric materials. Considerations include basic properties, evaporated dielectric materials, ceramic dielectri

  2. Modern algebra essentials

    CERN Document Server

    Lutfiyya, Lutfi A

    2012-01-01

    REA's Essentials provide quick and easy access to critical information in a variety of different fields, ranging from the most basic to the most advanced. As its name implies, these concise, comprehensive study guides summarize the essentials of the field covered. Essentials are helpful when preparing for exams, doing homework and will remain a lasting reference source for students, teachers, and professionals. Modern Algebra includes set theory, operations, relations, basic properties of the integers, group theory, and ring theory.

  3. Modern electrochemistry and industry

    International Nuclear Information System (INIS)

    Kim, Sun Yong

    1985-04-01

    This book is divided into fifteen chapters on modern electrochemistry and industry. The contents of this book are electrochemistry and industry, electrochemistry for electrolyte like ionic mobility quantity of activity of electrolyte, potential balance system like cell potential, concentration cell and membrane potential, electrochemical kinetics, electrochemistry for surfactant, electrochemistry for electrolysis test such as polarography, chronopotentiometry and Cyclic voltametry, electrolysis reactor NaOH electrolysis industry, H 2 O electrolysis, molten metal electrolysis, copper electrolysis, battery and electro-organic chemistry.

  4. Polymeric Biodegradable Stent Insertion in the Esophagus

    Directory of Open Access Journals (Sweden)

    Kai Yang

    2016-04-01

    Full Text Available Esophageal stent insertion has been used as a well-accepted and effective alternative to manage and improve the quality of life for patients diagnosed with esophageal diseases and disorders. Current stents are either permanent or temporary and are fabricated from either metal or plastic. The partially covered self-expanding metal stent (SEMS has a firm anchoring effect and prevent stent migration, however, the hyperplastic tissue reaction cause stent restenosis and make it difficult to remove. A fully covered SEMS and self-expanding plastic stent (SEPS reduced reactive hyperplasia but has a high migration rate. The main advantage that polymeric biodegradable stents (BDSs have over metal or plastic stents is that removal is not require and reduce the need for repeated stent insertion. But the slightly lower radial force of BDS may be its main shortcoming and a post-implant problem. Thus, strengthening support of BDS is a content of the research in the future. BDSs are often temporarily effective in esophageal stricture to relieve dysphagia. In the future, it can be expect that biodegradable drug-eluting stents (DES will be available to treat benign esophageal stricture, perforations or leaks with additional use as palliative modalities for treating malignant esophageal stricture, as the bridge to surgery or to maintain luminal patency during neoadjuvant chemoradiation.

  5. Targeted gene insertion for molecular medicine.

    Science.gov (United States)

    Voigt, Katrin; Izsvák, Zsuzsanna; Ivics, Zoltán

    2008-11-01

    Genomic insertion of a functional gene together with suitable transcriptional regulatory elements is often required for long-term therapeutical benefit in gene therapy for several genetic diseases. A variety of integrating vectors for gene delivery exist. Some of them exhibit random genomic integration, whereas others have integration preferences based on attributes of the targeted site, such as primary DNA sequence and physical structure of the DNA, or through tethering to certain DNA sequences by host-encoded cellular factors. Uncontrolled genomic insertion bears the risk of the transgene being silenced due to chromosomal position effects, and can lead to genotoxic effects due to mutagenesis of cellular genes. None of the vector systems currently used in either preclinical experiments or clinical trials displays sufficient preferences for target DNA sequences that would ensure appropriate and reliable expression of the transgene and simultaneously prevent hazardous side effects. We review in this paper the advantages and disadvantages of both viral and non-viral gene delivery technologies, discuss mechanisms of target site selection of integrating genetic elements (viruses and transposons), and suggest distinct molecular strategies for targeted gene delivery.

  6. Cigarette Mouth Insertion Depths Among Chinese Smokers

    Directory of Open Access Journals (Sweden)

    Hu Q

    2014-12-01

    Full Text Available Vent blocking - where filter ventilation holes are intentionally or unintentionally, partly or completely covered by smokers’ lips during smoking - is an aspect of smoking behavior which can alter mainstream smoke yields. This study was designed to determine if, and to what extent ventilation holes were blocked by smokers’ lips in two cohorts of Chinese smokers. In this study, two groups of samples were collected. One group (1742 butts was collected randomly from public places in six chosen cities. Another (1037 butts was obtained by collecting the butts from identified smokers in Kunming. In this paper, the mouth insertion depth among Chinese smokers was studied for the first time by a staining method employing ninhydrin in ethanol. The results indicate that Chinese smokers exhibit a mouth insertion depth ranging from 1 to 17 mm with an average value of 7.5 AA± 2 mm. In this study, 95% of the ventilated filters examined showed that the vent zone was neither completely nor partially covered by smokers’ lips.

  7. Safety analysis for reactivity insertion on ADS

    Energy Technology Data Exchange (ETDEWEB)

    Santos, Marcia S.; Velasquez, Carlos E.; Pereira, Claubia; Veloso, Maria Auxiliadora F.; Costa, Antonella L. [Universidade Federal de Minas Gerais (UFMG), Belo Horizonte, MG (Brazil). Departamento de Engenharia Nuclear; Barros, Graiciany de P. [Comissão Nacional de Energia Nuclear (CNEN), Rio de Janeiro, RJ (Brazil)

    2017-07-01

    In this work, an accelerator driven system (ADS) has been studied to fuel regeneration, partitioning and transmutation using fuel removed from LWR-spent fuel. This spent fuel was reprocessed by GANEX and then spiked with thorium. Monteburns 2.0 (MCNP5/ORIGEN 2.1) code was used to simulate burnup and neutronic parameters of the systems. However, these systems might be interrupted for some technical problems during few days or long periods to perform maintenance of accelerator systems without shutdown the fission system. Therefore, in this work, the aim was to investigate the nuclear fuel evolution in three different cases with reactivity insertions and variations in the functionality of the ADS. The evaluation has been performed for a burnup of 3 years, which are the most dangerous years in case of reactivity insertions. Therefore, in the first case the ADS during its burnup the external source (spallation source) is cutting off from the system several times during the first year of burnup. In the second case, it is simulated the reactor at different power from 0 (shutdown) to 1.5 times the 515MWt. The results shows the safety limits of the ADS for different situation. (author)

  8. Modern windships. Phase 1

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1996-11-01

    Knud E. Hansen A/S (KEH) has, partly funded by the Energy Research Programme, (EFP-95) investigated in the possibilities of using windships for transportation of cargo on long routes, i.e. across the Atlantic or Pacific Ocean. The task was to peruse experiences from projects made during the past 30 years and then, based on new materials and design principle to make proposals to modern wind driven ships to transportation of cargo - especially bulk carriers. KEH has thus prepared a suggestion for a 50,000 DWT wind driven bulk carrier on these terms. The bulk carrier in question is a modern rig inspired by the classical lugger and junk sail with a total sail area of abt. 10,000 m{sup 2}. The hull of the ship has been developed in order to limit wave resistance and drifting. Project Windship has, in contrast to earlier tests and projects, designed a bulk carrier based on a complete evaluation of ecology, safety, economy and reasonable transportation speed. The research project shows that international sea transportation, with wind as the primary source of energy, does not seem to run up against any obstacles as regards safety. The economical analyses show that windship transportation, with today`s oil prices, will be about 10% higher compared to the diesel driven transportation. In the light of the positive results of the research project the steering committee recommends that phase II of project `Modern Windships` is carried out. (EG)

  9. Modern windships. Phase 1

    International Nuclear Information System (INIS)

    1996-11-01

    Knud E. Hansen A/S (KEH) has, partly funded by the Energy Research Programme, (EFP-95) investigated in the possibilities of using windships for transportation of cargo on long routes, i.e. across the Atlantic or Pacific Ocean. The task was to peruse experiences from projects made during the past 30 years and then, based on new materials and design principle to make proposals to modern wind driven ships to transportation of cargo - especially bulk carriers. KEH has thus prepared a suggestion for a 50,000 DWT wind driven bulk carrier on these terms. The bulk carrier in question is a modern rig inspired by the classical lugger and junk sail with a total sail area of abt. 10,000 m 2 . The hull of the ship has been developed in order to limit wave resistance and drifting. Project Windship has, in contrast to earlier tests and projects, designed a bulk carrier based on a complete evaluation of ecology, safety, economy and reasonable transportation speed. The research project shows that international sea transportation, with wind as the primary source of energy, does not seem to run up against any obstacles as regards safety. The economical analyses show that windship transportation, with today's oil prices, will be about 10% higher compared to the diesel driven transportation. In the light of the positive results of the research project the steering committee recommends that phase II of project 'Modern Windships' is carried out. (EG)

  10. Code Modernization of VPIC

    Science.gov (United States)

    Bird, Robert; Nystrom, David; Albright, Brian

    2017-10-01

    The ability of scientific simulations to effectively deliver performant computation is increasingly being challenged by successive generations of high-performance computing architectures. Code development to support efficient computation on these modern architectures is both expensive, and highly complex; if it is approached without due care, it may also not be directly transferable between subsequent hardware generations. Previous works have discussed techniques to support the process of adapting a legacy code for modern hardware generations, but despite the breakthroughs in the areas of mini-app development, portable-performance, and cache oblivious algorithms the problem still remains largely unsolved. In this work we demonstrate how a focus on platform agnostic modern code-development can be applied to Particle-in-Cell (PIC) simulations to facilitate effective scientific delivery. This work builds directly on our previous work optimizing VPIC, in which we replaced intrinsic based vectorisation with compile generated auto-vectorization to improve the performance and portability of VPIC. In this work we present the use of a specialized SIMD queue for processing some particle operations, and also preview a GPU capable OpenMP variant of VPIC. Finally we include a lessons learnt. Work performed under the auspices of the U.S. Dept. of Energy by the Los Alamos National Security, LLC Los Alamos National Laboratory under contract DE-AC52-06NA25396 and supported by the LANL LDRD program.

  11. Adaptive significance of root grafting in trees

    Energy Technology Data Exchange (ETDEWEB)

    Loehle, C.; Jones, R.

    1988-12-31

    Root grafting has long been observed in forest trees but the adaptive significance of this trait has not been fully explained. Various authors have proposed that root grafting between trees contributes to mechanical support by linking adjacent root systems. Keeley proposes that this trait would be of greatest advantage in swamps where soils provide poor mechanical support. He provides as evidence a greenhouse study of Nyssa sylvatica Marsh in which seedlings of swamp provenance formed between-individual root grafts more frequently than upland provenance seedlings. In agreement with this within-species study, Keeley observed that arid zone species rarely exhibit grafts. Keeley also demonstrated that vines graft less commonly than trees, and herbs never do. Since the need for mechanical support coincides with this trend, these data seem to support his model. In this paper, the authors explore the mechanisms and ecological significance of root grafting, leading to predictions of root grafting incidence. Some observations support and some contradict the mechanical support hypothesis.

  12. Autologous patch graft in tube shunt surgery.

    Science.gov (United States)

    Aslanides, I M; Spaeth, G L; Schmidt, C M; Lanzl, I M; Gandham, S B

    1999-10-01

    To evaluate an alternate method of covering the subconjunctival portion of the tube in aqueous shunt surgery. Evidence of tube erosion, graft-related infection, graft melting, or other associated intraocular complications were evaluated. A retrospective study of 16 patients (17 eyes) who underwent tube shunt surgery at Wills Eye Hospital between July 1991 and October 1996 was conducted. An autologous either "free" or "rotating" scleral lamellar graft was created to cover the subconjunctival portion of the tube shunt. All patients were evaluated for at least 6 months, with a mean follow-up of 14.8 months (range 6-62 months). All eyes tolerated the autologous graft well, with no clinical evidence of tube erosion, or graft-related or intraocular complications. Autologous patch graft in tube shunt surgery appears--in selected cases--to be an effective, safe and inexpensive surgical alternative to allogenic graft materials. It also offers ease of availability, and eliminates the risk of transmitting infectious disease.

  13. Radiation induced graft copolymerization of jute fibre

    International Nuclear Information System (INIS)

    Al-Siddique, F.R.; Khan, A.U.; Sheikh, R.A.

    1983-01-01

    Graft copolymerized jute fibres (GCJF) were prepared by γ-ray induced graft copolymerization of various monomers onto bleached and de-waxed jute samples. The effect of γ-ray dose on the tendency of various monomers to form graft co-polymer was studied. It was found that the tendency decreases as follows: methylmethacrylate (MMA)>acrylonitrile (AN)>styrene (STY)>vinylacetate (VA). When the effect of monomer concentration on the formation of graft co-polymer was studied, it was found that a mixture of AN and STY gave a higher amount of grafting than what was observed for STY or AN alone, when used at a comparable concentration. A study on the effect of concentration of methyl alcohol (a swelling agent for jute) on the tendency of the monomers to form graft co-polymer showed that although there is no effect when only AN is used, an appreciable effect is observed if AN is mixed with STY. In the later case the tendency of graft co-polymerization increases with the increase of CH 3 OH concentration. It was further observed that the increase of CH 3 OH also has a positive influence on MMA to form graft co-polymer in the range of 40-90% CH 3 OH. The affinity of GCJF towards moisture has been found to decrease with the increase of polymer loading onto jute. The presence of swelling agents during graft copolymer formation was also found to decrease the affinity of GCJF towards moisture. (author)

  14. Clinical observation on the reconstruction of large areas lower eyelid defect with Medpor spacer graft

    Directory of Open Access Journals (Sweden)

    Hai-Yan Li

    2014-08-01

    Full Text Available AIM: To observe the effects of porous polyethylene(Medporas a spacer graft in the reconstruction of large areas eyelid defect after the operation of malignant tumors of lower eyelids.METHODS: Nineteen cases(19 eyesof malignant tumors of lower eyelid underwent the eyelid reconstruction were selected. Medpor lower eyelid inserts implantation were used to replace tarsal joint sliding conjunctival flap and pedicle flap, and repaired full-thickness lower eyelid defects then underwent eyelid reconstruction. RESULTS: Appearance of eyelids and functional improvements were satisfactory with no stimulation on the eyeball and no effect on the visual function. Implants is with no absorption, shift, exclusion or infection and no tumor recurrence in all cases during the follow up for 6-36mo.CONCLUSION: Medpor lower eyelid inserts implantation can instead tarsal plate for the reconstruction of medium to large areas lower eyelid defect, which is easy performing with rare complications. It is an ideal alternatives of tarsal plate.

  15. Acrylique acid grafted polyolefines. Thermoadhesive applications

    International Nuclear Information System (INIS)

    Guimon, Claude

    1979-01-01

    Radiochemical grafting of polyolefines by peroxidation has been industrialized in France for about 10 years by irradiation of these polymers with an electron accelerator and then treated by acrylic acid. Products obtained show a high adhesivity on metallic surfaces above their melting point. The main application of acrylic acid grafted high density polyethylene is composite film with aluminum foil for thermosealing of plastic bottle caps of sterilized milk. Acrylic acid grafted polypropylene is used in suspension in a volatile liquid for aluminum foil coating satisfying food packaging regulations [fr

  16. Grafting heterogeneous catalyst with gamma radiation

    International Nuclear Information System (INIS)

    Garnett, J.L.; Long, M.A.; Levot, R.G.

    1984-01-01

    A process for the production of a heterogeneous catalyst comprises the steps of: irradiating an organic macromolecular substrate or a metal substrate with ionising or ultra violet radiation in the presence of a monomer selected from the group consisting of o-, m-, or p- styryl diphenyl phosphine and o-, m- or p- phenyl acrylyl diphenyl phosphine, to graft the monomer to the substrate; and reacting the graft copolymer with a homogeneous catalyst selected from the group consisting of catalytic metal salts and catalytic organometallic complexes such that the graft copolymer conjugate becomes a ligand of the catalyst

  17. Bone Graft Substitutes : Developed for Trauma and Orthopaedic Surgery

    NARCIS (Netherlands)

    J. van der Stok (Johan)

    2015-01-01

    markdownabstract__Abstract__ Bone grafting was established in the 19th century and has become a common procedure in which bone defects are filled with bone grafts or bone graft substitutes. Bone defects that require bone grafting are encountered in approximately 10% of trauma and orthopaedic

  18. Vascularised Fibular Graft for a Radial Defect following Tumour ...

    African Journals Online (AJOL)

    HP

    The mass was located on the radial aspect of the distal right ... modification, internal or external fixation with bone grafting, structural grafts of ... Our index case report demonstrates that free vascularized fibular graft transfer is a feasible option ... structural support, the potential for graft hypertrophy, relative resistance to ...

  19. Hot callusing for propagation of American beech by grafting

    Science.gov (United States)

    David W. Carey; Mary E. Mason; Paul Bloese; Jennifer L. Koch

    2013-01-01

    To increase grafting success rate, a hot callus grafting system was designed and implemented as part of a multiagency collaborative project to manage beech bark disease (BBD) through the establishment of regional BBD-resistant grafted seed orchards. Five years of data from over 2000 hot callus graft attempts were analyzed using a logistic regression model to determine...

  20. Modernization of African Armed Forces

    DEFF Research Database (Denmark)

    Mandrup, Thomas

    2015-01-01

    Concept paper framing the debate at the Dakar Forum Workshop on Modernization of Armed forces in Africa.......Concept paper framing the debate at the Dakar Forum Workshop on Modernization of Armed forces in Africa....

  1. Method Of Wire Insertion For Electric Machine Stators

    Science.gov (United States)

    Brown, David L; Stabel, Gerald R; Lawrence, Robert Anthony

    2005-02-08

    A method of inserting coils in slots of a stator is provided. The method includes interleaving a first set of first phase windings and a first set of second phase windings on an insertion tool. The method also includes activating the insertion tool to radially insert the first set of first phase windings and the first set of second phase windings in the slots of the stator. In one embodiment, interleaving the first set of first phase windings and the first set of second phase windings on the insertion tool includes forming the first set of first phase windings in first phase openings defined in the insertion tool, and forming the first set of second phase windings in second phase openings defined in the insertion tool.

  2. Bridging Graft in Irreparable Massive Rotator Cuff Tears: Autogenic Biceps Graft versus Allogenic Dermal Patch Graft.

    Science.gov (United States)

    Rhee, Sung Min; Oh, Joo Han

    2017-12-01

    Few comparative studies have reported on the use of biologic grafts for irreparable massive rotator cuff tears. The purpose of this study was to assess the results of arthroscopic bridging graft in irreparable massive rotator cuff tears using an autogenic long head of biceps tendon (LHBT) or an allogenic dermal patch (ADP). We retrospectively reviewed 24 patients treated using the LHBT (group I) and eight patients with complete rupture of the LHBT treated using an ADP (group II) since 2011. Preoperative Goutallier's fatty degeneration, range of motion (ROM), visual analogue scale (VAS) for pain, American Shoulder and Elbow Surgeons (ASES) score, and Quick Disabilities of the Arm, Shoulder, and Hand (DASH) score were assessed and healing failure was evaluated at 1 year after surgery by ultrasonography or magnetic resonance imaging. The mean fatty degeneration in groups I and II was 3.9 and 3.6 for the supraspinatus ( p = 0.288), 2.7 and 2.9 for the infraspinatus ( p = 0.685), 0.9 and 1.3 for the subscapularis ( p = 0.314), and 1.3 and 3.0 for the teres minor ( p = 0.005), respectively. Subscapularis tears were found in 8 patients (33.3%) in group I and in 7 patients (87.5%) in group II ( p = 0.023). Mean ROMs and functional scores improved significantly in group I (forward flexion: 121.7° to 153.3°, p = 0.010; external rotation: 32.7° to 52.7°, p = 0.001; external rotation at 90°: 63.3° to 74.5°, p = 0.031; internal rotation: T10.5 to T9.3, p = 0.045; VAS: 7.0 to 1.1, p rotator cuff tears, especially in patients with severe fatty degeneration in the teres minor or combined biceps and subscapularis tears.

  3. Feasibility of the Use of RapiGraft and Skin Grafting in Reconstructive Surgery

    Directory of Open Access Journals (Sweden)

    Jung Dug Yang

    2016-09-01

    Full Text Available BackgroundSkin grafting is a relatively simple and thus widely used procedure. However, the elastic and structural quality of grafted skin is poor. Recently, various dermal substitutes have been developed to overcome this disadvantage of split-thickness skin grafts. The present study aims to determine the feasibility of RapiGraft as a new dermal substitute.MethodsThis prospective study included 20 patients with partial- or full-thickness skin defects; the patients were enrolled between January 2013 and March 2014. After skin defect debridement, the wound was divided into two parts by an imaginary line. Split-thickness skin grafting alone was performed on one side (group A, and RapiGraft and split-thickness skin grafting were used on the other side (group B. All patients were evaluated using photographs and self-questionnaires. The Manchester scar scale (MSS, a chromameter, and a durometer were used for the scar evaluation. The average follow-up period was 6 months.ResultsThe skin graft take rates were 93% in group A and 89% in group B, a non-significant difference (P=0.082. Statistically, group B had significantly lower MSS, vascularity, and pigmentation results than group A (P<0.05 for all. However, the groups did not differ significantly in pliability (P=0.155.ConclusionsThe present study indicates that a simultaneous application of RapiGraft and a split-thickness skin graft is safe and yields improved results. Therefore, we conclude that the use of RapiGraft along with skin grafting will be beneficial for patients requiring reconstructive surgery.

  4. Delayed grafting for banked skin graft in lymph node flap transfer.

    Science.gov (United States)

    Ciudad, Pedro; Date, Shivprasad; Orfaniotis, Georgios; Dower, Rory; Nicoli, Fabio; Maruccia, Michele; Lin, Shu-Ping; Chuang, Chu-Yi; Chuang, Tsan-Yu; Wang, Gou-Jen; Chen, Hung-Chi

    2017-02-01

    Over the last decade, lymph node flap (LNF) transfer has turned out to be an effective method in the management of lymphoedema of extremities. Most of the time, the pockets created for LNF cannot be closed primarily and need to be resurfaced with split thickness skin grafts. Partial graft loss was frequently noted in these cases. The need to prevent graft loss on these iatrogenic wounds made us explore the possibility of attempting delayed skin grafting. We have herein reported our experience with delayed grafting with autologous banked split skin grafts in cases of LNF transfer for lymphoedema of the extremities. Ten patients with International Society of Lymphology stage II-III lymphoedema of upper or lower extremity were included in this study over an 8-month period. All patients were thoroughly evaluated and subjected to lymph node flap transfer. The split skin graft was harvested and banked at the donor site, avoiding immediate resurfacing over the flap. The same was carried out in an aseptic manner as a bedside procedure after confirming flap viability and allowing flap swelling to subside. Patients were followed up to evaluate long-term outcomes. Flap survival was 100%. Successful delayed skin grafting was done between the 4th and 6th post-operative day as a bedside procedure under local anaesthesia. The split thickness skin grafts (STSG) takes more than 97%. One patient needed additional medications during the bedside procedure. All patients had minimal post-operative pain and skin graft requirement. The patients were also reported to be satisfied with the final aesthetic results. There were no complications related to either the skin grafts or donor sites during the entire period of follow-up. Delayed split skin grafting is a reliable method of resurfacing lymph node flaps and has been shown to reduce the possibility of flap complications as well as the operative time and costs. © 2016 Medicalhelplines.com Inc and John Wiley & Sons Ltd.

  5. Preparation of poly(vinylbenzyl chloride)-grafted PFA film by a simultaneous irradiation grafting method

    International Nuclear Information System (INIS)

    Fei, Geng; Shin, Jun Hwa; Nho, Young Chang; Lee, Youn Sik

    2009-01-01

    In this study, PFA-g-PVBC films were prepared by a radiation grafting of vinylbenzyl chloride (VBC) monomer onto poly(tetrafluoroethylene-co-perfluoro propyl vinyl ether) (PFA) films by simultaneous irradiation method. IR, TGA, and SEM-EDX instruments were utilized to confirm the successful preparation of the grafted film. The effects of several irradiation conditions, including the dose, VBC concentration, and film thickness on the degree of grafting of PFA-g-PVBC film were investigated

  6. Free fibular strut graft in neglected femoral neck fractures in adult

    Directory of Open Access Journals (Sweden)

    Azam Md Quamar

    2009-01-01

    Full Text Available Background: Neglected femoral neck fracture in adults still poses a formidable challenge. Existing treatment options varies from osteotomy (with or without graft to osteosynthesis using various implants and grafting techniques (muscle pedicle, vascularized, and nonvascularized fibula. The aim of this study was to assess outcome of nonvascularized fibular strut graft and cancellous screw fixation in neglected femoral neck fractures in the younger age group. Materials and Methods: Medical records of 32 patients of neglected femoral neck fracture, in the age group of 22-45 years (mean 37.8 years, operated between May 1994 to December 2001, were retrospectively reviewed. After the application of inclusion and exclusion criteria, 28 patients having three years minimum follow-up (mean 4.6 years were included. Delay between injury and operation varied from four weeks to 42 weeks (mean 16.4 weeks. Closed reduction was achieved in 17 patients; open reduction through Watson-Jones anterolateral approach was performed in the remaining 15 patients in whom closed reduction failed. The fracture was transfixed with three parallel guide wires. Appropriate sized cannulated lag screw (7 mm was then inserted in two of the wires. Selection of the third guide wire for fibula depended on the space available in both anteroposterior and lateral view. Results: Satisfactory bony union was obtained in 25 patients, of whom in four cases, the union occurred in 10-20° (mean 15° of varus. Nonunion occurred in three patients (9.37%, and aseptic necrosis occurred in another six patients (18.75%. Of the 25 patients where union was achieved, five patients showed excellent results; 14 good and six had poor functional result, as evaluated using modified Anglen criteria. Conclusion: Nonvascularized fibular strut graft along with cancellous screws provides a dependable and technically less-demanding alternative procedure for neglected femoral neck fractures in young adults. Fibula

  7. Full-thickness skin mesh graft vaginoplasty: a skin sparing technique

    Directory of Open Access Journals (Sweden)

    Guilherme Lang Motta

    Full Text Available ABSTRACT Introduction: The ideal vaginoplasty method should promote good cosmetic and functional results with low morbidity. We describe a new technique for congenital vaginal agenesis using a full-thickness perforated skin graft. Materials and Methods: We report an 18 year old patient with vaginal agenesis (Morris syndrome that undergone a modified version of McIndoe vaginoplasty. Patient is set in a low lithotomy position and lateral traction sutures are placed in labia and a 16Fr urethral catheter inserted. An inverted “V”-shaped incision is made in the mucosal plaque below the urethra. Blunt dissection in a cephalic posterior direction forms a space between the rectum and urethra. Special care is taken to avoid rectal tear during this maneuver. A full-thickness skin graft is removed from the lower abdomen measuring 12.0×6.0cm as an aesthetic abdominoplasty. The fat tissue is removed, remaining epidermis and dermis and the graft is perforated, allowing a great surface increase. After suturing over a mold, the graft is fixed in the created space. The donor site is closed with intradermal transversal suture. Results: From January 2009 to August 2015, seven patients diagnosed with vaginal agenesis underwent this technique. There were no major complications or need for blood transfusions. At the six-month follow-up, all patients reported satisfactory sexual intercourse. There were no significant complications at donor site or neovagina that needed surgical intervention. Conclusion: Vaginal reconstruction using the perforated graft is viable with excellent functional results. Applying this modification, we yielded the good results of a classic McIndoe technique with lower donor site morbidity.

  8. Percutaneous endovascular stent-graft treatment of aortic aneurysms and dissections: new techniques and initial experience

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Do Yun; Choi, Dong Hoon; Kang, Sung Gwon; Lee, Kwang Hoon; Won, Jong Yun [Yonsei University College of Medicine, Seoul (Korea, Republic of); Kang, Sung Gwon [Chosun University College of Medicine, Gwangju (Korea, Republic of); Won, Je Whan [Aju University College of Medicine, Suwon (Korea, Republic of); Song, Ho Young [Ulsan University College of Medicine, Seoul (Korea, Republic of)

    2003-01-01

    To evaluate the feasibility, safety and effectiveness of a newly designed percutaneously implanted separate stent-graft (SSG) for the treatment of aortic aneurysms and dissections. Using a percutaneous technique, SSG placement (in the descending thoracic aorta in 26 cases and infrarenal abdominal aorta in 24) was attempted in 50 patients with aortic aneurysms (n=27) or dissection (n=23). All SSGs were individually constructed using self-expandable nitinol stents and a Dacron graft, and were introduced through a 12 F sheath and expanded to a diameter of 20-34 mm. In all cases, vascular access was through the femoral artery. The clinical status of each patient was monitored, and postoperative CT was performed within one week of the procedure and at 3-6 month intervals afterwards. Endovascular stent-graft deployment was technically successful in 49 of 50 patients (98%). The one failure was due to torsion of the unsupported graft during deployment. Successful exclusion of aneurysms and the primary entry tears of dissections was achieved in all but three patients with aortic dissection. All patients in whom technical success was achieved showed complete thrombosis of the thoracic false lumen or aneurysmal sac, and the overall technique success rate was 92%. In addition, sixteen patients demonstrated complete resolution of the dissected thoracic false lumen (n=9) or aneurysmal sac (n=7). Immediate post-operative complications occurred at the femoral puncture site in one patient with an arteriovenous fistula, and in two, a new saccular aneurysm developed at the distal margin of the stent. No patients died, and there was no instance of paraplegia, stroke, side-branch occlusion or infection during the subsequent mean follow-up period of 9.4 (range, 2 to 26) months. In patients with aortic aneurysm and dissection, treatment with a separate percutaneously inserted stent-graft is technically feasible, safe, and effective.

  9. Hand-actuated spring clip insertion tool

    International Nuclear Information System (INIS)

    Cuba, G.W.

    1993-01-01

    A hand-actuated insertion tool includes a handle assembly, an elongated hollow tubular outer support tube, an elongated inner pull rod, and a coupling arrangement. The handle assembly has a first handle member and a second handle member pivoted to a member for movement between unactuated and actuated positions. The tube is attached in a fixed relation to a handle member. The rod is mounted within the tube for sliding movement relative thereto between home and retracted positions. The coupling arrangement pivotally connects the rod to the second handle member such that the rod will undergo sliding movement from the home position to the retracted positions relative to the tube as the second handle member is moved from the unactuated position to the actuated position adjacent to the first handle member. (author)

  10. MORPH INSERTION AND ALLOMORPHY IN OPTIMALITY THEORY

    Directory of Open Access Journals (Sweden)

    Eulalia Bonet

    2004-12-01

    Full Text Available The goal of this paper is to compare two different hypotheses about the insertion of morphs and allomorphy in Optimality Theory. One of them, the Morphs through Constraifits Hypothesis (MCH claims that the phonological realization of morphemes (morphs is introduced through language-particular constraints. The other hypothesis, the Morphs in the Input Hypothesis (MIH claims that the inputs to GEN contain al1 the relevant phonological information. It is shown that the MIH is clearly superior to the MCH in accounting for voicing neutralization in languages like Catalan. The two hypotheses seem to fare even in dealing with other phenomena, such as phonologically-conditioned allomorphy or OCP-triggered epenthesis vs. haplology in English possessives and plurals. Finally, although the MCH seems to be a simpler hypothesis for lexical exceptions, it is shown that, when certain aspects are taken into account, it runs into problems.

  11. An update on insertable cardiac monitors

    DEFF Research Database (Denmark)

    Olsen, Flemming J; Biering-Sørensen, Tor; Krieger, Derk W

    2015-01-01

    Continuous cardiac rhythm monitoring has undergone compelling progress over the past decades. Cardiac monitoring has emerged from 12-lead electrocardiograms being performed at the discretion of the treating physician to in-hospital telemetry, Holter monitoring, prolonged external event monitoring...... turning point in the field of arrhythmia management. However, their role in the detection of paroxysmal atrial fibrillation after cryptogenic strokes has yet to evolve. This will be the main focus of this review. Issues surrounding patient selection, clinical relevance and determination of cost......-effectiveness for prolonged cardiac monitoring require further studies. Furthermore, insertable cardiac monitoring has not only the potential to augment diagnostic capabilities but also to improve the management of paroxysmal atrial fibrillation....

  12. Cassini-Huygens Nears Saturn Orbit Insertion

    Science.gov (United States)

    Showstack, Randy

    2004-06-01

    After nearly 7 years and a 3.5-billion-km, circuitous journey from Earth, the $3-billion Cassini-Huygens mission to Saturn and Titan-an international effort by NASA, the European Space Agency, and the Italian Space Agency-now is just days away from its critical Saturn orbit insertion. Scheduled for 30 June, this will begin the 4-years part of the mission to study the Saturnian system. At a 3 June briefing at NASA headquarters in Washington, D.C., Robert Mitchell, the Cassini program manager with the Jet Propulsion Laboratory in Pasadena, California, said that scientists involved with the program are feeling excited, relieved, and also a bit anxious as the Cassini-Huygens spacecraft draws near to the ringed planet and its system.

  13. Insertion Device Upgrade Plans at the NSLS

    CERN Document Server

    Tanabe, Toshiya; Harder, David; Lehecka, Michael; Rakowsky, George; Skaritka, John

    2005-01-01

    This paper describes plans to upgrade insertion devices at the National Synchrotron Light Source (NSLS), Brookhaven National Laboratory, U.S.A. The aging wiggler (W80) at X25 is being replaced by a 1 m long in-vacuum mini-gap undulator (MGU-18) optimized for a dedicated macromolecular crystallography program. A new, 1/3 m long, in-vacuum undulator (MGU-13.5), will be installed between a pair of RF cavities at X9, and will serve a new beamline dedicated for small angle x-ray scattering (SAXS). Both MGU’s will have provision for cryocooling the NdFeB hybrid arrays to 150K to raise the field and K-value and to obtain better spectral coverage. Design issues of the devices and other considerations, especially magnetic measurement methods in low temperature will be discussed.

  14. Quench Performance of the LHC Insertion Magnets

    CERN Document Server

    Lasheras, N C; Siemko, A; Ostojic, R; Kirby, G

    2009-01-01

    After final installation in the LHC tunnel, the MQM and MQY quadrupole magnets of the LHC insertions are now being commissioned to their nominal currents. These two types of magnets operate at 1.9 K and 4.5 K and with nominal currents ranging from 3600 A to 5390 A. From the very first acceptance tests of the bare magnets coming from the manufacturers, they have been powered using different cycles, in different configurations, at different temperatures and in different tests facilities. In this paper we present the global results of these powering tests. We aim at separating common from individual features of these groups of magnets. Temperature dependence of the training, temperature margin, and ultimate current can be extracted from these tests. As these magnets are used to match the optics and the dispersion in the machine, the projected ultimate current at which they can be operated is critical in view of operation of LHC.

  15. Determination of the distribution of graft yields following a radiation-induced graft copolymerization

    International Nuclear Information System (INIS)

    Schipschack, K.; Wagner, H.; Sawtschenko, L.

    1976-01-01

    In the radiation-induced graft copolymerization on solid initial polymers a distribution of graft yields takes place along the cross-sections of samples. Methods for determining this distribution, which are described in the literature, are reviewed. In our own investigations boards made of ethylene-vinyl acetate copolymers and grafted with vinyl chloride were used. Distributions of the grafted component obtained by infrared analysis of microtome cuts parallel to the surface are partly rather inhomogeneous, and are interpreted as dependent on the experimental parameters. (author)

  16. Enrichment of autologous fat grafts with ex-vivo expanded adipose tissue-derived stem cells for graft survival

    DEFF Research Database (Denmark)

    Kølle, Stig-Frederik Trojahn; Fischer-Nielsen, Anne; Mathiasen, Anders Bruun

    2013-01-01

    Autologous fat grafting is increasingly used in reconstructive surgery. However, resorption rates ranging from 25% to 80% have been reported. Therefore, methods to increase graft viability are needed. Here, we report the results of a triple-blind, placebo-controlled trial to compare the survival ...... of fat grafts enriched with autologous adipose-derived stem cells (ASCs) versus non-enriched fat grafts....

  17. Compliance Study of Endovascular Stent Grafts Incorporated with Polyester and Polyurethane Graft Materials in both Stented and Unstented Zones

    Directory of Open Access Journals (Sweden)

    Ying Guan

    2016-08-01

    Full Text Available Compliance mismatch between stent graft and host artery may induce complications and blood flow disorders. However, few studies have been reported on stent graft compliance. This study aims to explore the deformation and compliance of stent graft in stented and unstented zones under three pressure ranges. Compliance of two stent grafts incorporated with polyurethane graft (nitinol-PU and polyester graft (nitinol-PET materials respectively were tested; the stents used in the two stent grafts were identical. For the circumferential deformation of the stent grafts under each pressure range, the nitinol-PET stent graft was uniform in both zones. The nitinol-PU stent graft was circumferentially uniform in the stented zone, however, it was nonuniform in the unstented zone. The compliance of the PU graft material was 15 times higher than that of the PET graft. No significant difference in compliance was observed between stented and unstented zones of the nitinol-PET stent graft regardless of the applied pressure range. However, for the nitinol-PU stent graft, compliance of the unstented PU region was approximately twice that of the stented region; thus, compliance along the length of the nitinol-PU stent graft was not constant and different from that of the nitinol-PET stent graft.

  18. Regulatory perspective on incomplete control rod insertions

    International Nuclear Information System (INIS)

    Chatterton, M.

    1997-01-01

    The incomplete control rod insertions experienced at South Texas Unit 1 and Wolf Creek are of safety concern to the NRC staff because they represent potential precursors to loss of shutdown margin. Even before it was determined if these events were caused by the control rods or by the fuel there was an apparent correlation of the problem with high burnup fuel. It was determined that there was also a correlation between high burnup and high drag forces as well as with rod drop time histories and lack of rod recoil. The NRC staff initial actions were aimed at getting a perspective on the magnitude of the problem as far as the number of plants and the amount of fuel that could be involved, as well as the safety significance in terms of shutdown margin. As tests have been performed and data has been analyzed the focus has shifted more toward understanding the problem and the ways to eliminate it. At this time the staff's understanding of the phenomena is that it was a combination of factors including burnup, power history and temperature. The problem appears to be very sensitive to these factors, the interaction of which is not clearly understood. The model developed by Westinghouse provides a possible explanation but there is not sufficient data to establish confidence levels and sensitivity studies involving the key parameters have not been done. While several fixes to the problem have been discussed, no definitive fixes have been proposed. Without complete understanding of the phenomena, or fixes that clearly eliminate the problem the safety concern remains. The safety significance depends on the amount of shutdown margin lost due to incomplete insertion of the control rods. Were the control rods to stick high in the core, the reactor could not be shutdown by the control rods and other means such as emergency boration would be required

  19. Institutions and Modernity

    Directory of Open Access Journals (Sweden)

    Witold Morawski

    2013-09-01

    Full Text Available Purpose: Modernity consists of many confl icting aspects: It brings many empty promises, yet has resulted in new institutions that create bridges between the values and interests of millions of people who seek freedom, prosperity, quality of life, strengthened democracy and social justice. In this paper I attempt to a gain and loss account against modernity, because institutional rules are not only conducive to cooperative interactions, but to hostile interactions as well. People are not always guided by moral commitment, but rather more often driven by cold calculation or coercion.Methodology: Modernity has at least three defi nitions. The fi rst defi nition is based on ideas that took over the imagination of the era. The second defi nition is based on an analysis of the behavior of people who respond to reason as well as emotion and believe that they act more rationally than their ancestors or the traditional “others”. The third defi nition is the one closest to my heart, consisting of the use of institutional categories. Institutions offer practical ways of connecting ideas and people. The challenge for them is the result of deepening local and national interdependencies, but increasingly often also regional (e.g. European and global. Interdependencies are the result of the scientifi c and technological revolution, global markets, global governance mechanisms, the emergence of new social forces and cultural confl icts (against the background of reconciling identity and differences.Conclusions: The most important task is to identify the mechanisms of complex systems so that people know how to act under conditions of uncertainty, risk and crisis. Hence, the expectations toward institutions often exceed their abilities. Even though new institutions are being created and old ones are being fixed, we are witnessing and participating in, institutional paralysis and the decay (e.g. corruption. In this situation, it is imperative not only to

  20. An Introduction to the Septal Extension Graft

    Directory of Open Access Journals (Sweden)

    Myung-Hoon Kim

    2014-01-01

    Full Text Available The septal extension graft is a very useful method of controlling nasal lengthening and tip projection, rotation, and shape by fixing a graft to the septum, which leads to a strong supporting structure. Enhancing graft stability is important for better long-term outcomes and minimizing complications or relapse, and even more efficient application of these methods is needed for East Asians who lack enough cartilage to be harvested in addition to possessing a weak cartilage framework. In this paper, the methods for overcoming the drawbacks of the septal extension graft, such as instability, a fixed tip, and insufficiency of cartilage, are presented, and the applications of each method for greater satisfaction with surgical outcomes are also discussed.

  1. Radiation-induced grafting onto wool

    International Nuclear Information System (INIS)

    Muller-Schulte, D.

    1979-10-01

    Radiation-induced grafting tests were done on single wool fibres. Different vinyl monomers were used for this purpose and they were grafted in twenty different solvents which were selected for their swelling effiency and solvent parameters. The tests were done once with and once without the addition of water. The presence of water causes the polymer uptake to increase considerably. Formic acid/methanol and methanol were found to be the most suitable solvent systems, as they have the highest hydrogen-bond interaction effiency. The moisture uptake of wool depends on the hydrophily and hydrophoby of the grafted polymers. The single-fibre tests serve as a basis for analogous grafting tests on wool fabrics. The permanent- press was improved by graftng with hydrophoric polymers and polymers with a high glass-transition temperature [af

  2. Visualization in modern cartography

    CERN Document Server

    MacEachren, AM

    1994-01-01

    Visualization in Modern Cartography explores links between the centuries-old discipline of cartography and today's revolutionary developments in scientific visualization. The book has three main goals: (1) to pass on design and symbolization expertise to the scientific visualization community - information that comes from centuries of pre-computer visualization by cartographers, and their more recent experiences with computerizing the discipline; (2) to help cartographers cope with the dramatic shift from print cartography to a dynamic virtual cartography for which their role is changing from

  3. Modern gear production

    CERN Document Server

    Watson, H J

    1970-01-01

    Modern Gear Production focuses on the processes and methods in gear making. The book first gives information on the history of gear making and types of gears. Topics such as the classification of gears based on the disposition of their shafts; shafts lying in the same plane with axes intersecting; and shafts lying in parallel planes but with axes inclined to one another are then discussed. The text describes gear groups, tooth forms, and gear materials. Heat treatment of steels, casehardening, nitriding, induction hardening, sulfinuzing, and flame hardening are explained. The book takes a look

  4. Modern Physics Simulations

    Science.gov (United States)

    Brandt, Douglas; Hiller, John R.; Moloney, Michael J.

    1995-10-01

    The Consortium for Upper Level Physics Software (CUPS) has developed a comprehensive series of Nine Book/Software packages that Wiley will publish in FY `95 and `96. CUPS is an international group of 27 physicists, all with extensive backgrounds in the research, teaching, and development of instructional software. The project is being supported by the National Science Foundation (PHY-9014548), and it has received other support from the IBM Corp., Apple Computer Corp., and George Mason University. The Simulations being developed are: Astrophysics, Classical Mechanics, Electricity & Magnetism, Modern Physics, Nuclear and Particle Physics, Quantum Mechanics, Solid State, Thermal and Statistical, and Wave and Optics.

  5. Modern TTL circuits manual

    CERN Document Server

    Marston, R M

    2013-01-01

    Modern TTL Circuits Manual provides an introduction to the basic principles of Transistor-Transistor Logic (TTL). This book outlines the major features of the 74 series of integrated circuits (ICs) and introduces the various sub-groups of the TTL family.Organized into seven chapters, this book begins with an overview of the basics of digital ICs. This text then examines the symbology and mathematics of digital logic. Other chapters consider a variety of topics, including waveform generator circuitry, clocked flip-flop and counter circuits, special counter/dividers, registers, data latches, com

  6. Dialogues on modern physics

    CERN Document Server

    Sachs, Mendel

    1998-01-01

    In this book, important conceptual developments of the two major revolutions of modern physics - the quantum and relativity theories - are presented in a nonmathematical, dialectical form of dialogue. The implications of conflicting philosophical attitudes of these revolutions in physics and applications to topics such as cosmology/astrophysics and high energy physics are emphasized. It is argued that for any substantial progress in our understanding of 21st century physics, it will be necessary to resolve these 20th century conflicts. These richly rewarding dialogues provide a starting point

  7. Introduction to modern cryptography

    CERN Document Server

    Katz, Jonathan

    2014-01-01

    Praise for the First Edition:""This book is a comprehensive, rigorous introduction to what the authors name 'modern' cryptography. … a novel approach to how cryptography is taught, replacing the older, construction-based approach. … The concepts are clearly stated, both in an intuitive fashion and formally. … I would heartily recommend this book to anyone who is interested in cryptography. … The exercises are challenging and interesting, and can benefit readers of all academic levels.""-IACR Book Reviews, January 2010""Over the past 30 years, cryptography has been transformed from a mysterious

  8. Liminality and the Modern

    DEFF Research Database (Denmark)

    Thomassen, Bjørn

    This book provides the history and genealogy of an increasingly important subject: liminality. Coming to the fore in recent years in social and political theory and extending beyond is original use as developed within anthropology, liminality has come to denote spaces and moments in which the taken...... of the liquid structures of modern society. Shedding new light on a concept central to social thought, as well as its capacity for pushing social and political theory in new directions, this book will be of interest to scholars across the social sciences and philosophy working in fields such as social...

  9. Modern fluid dynamics

    CERN Document Server

    Kleinstreuer, Clement

    2018-01-01

    Modern Fluid Dynamics, Second Edition provides up-to-date coverage of intermediate and advanced fluids topics. The text emphasizes fundamentals and applications, supported by worked examples and case studies. Scale analysis, non-Newtonian fluid flow, surface coating, convection heat transfer, lubrication, fluid-particle dynamics, microfluidics, entropy generation, and fluid-structure interactions are among the topics covered. Part A presents fluids principles, and prepares readers for the applications of fluid dynamics covered in Part B, which includes computer simulations and project writing. A review of the engineering math needed for fluid dynamics is included in an appendix.

  10. Modern vacuum physics

    CERN Document Server

    Chambers, Austin

    2005-01-01

    Modern Vacuum Physics presents the principles and practices of vacuum science and technology along with a number of applications in research and industrial production. The first half of the book builds a foundation in gases and vapors under rarefied conditions, The second half presents examples of the analysis of representative systems and describes some of the exciting developments in which vacuum plays an important role. The final chapter addresses practical matters, such as materials, components, and leak detection. Throughout the book, the author''s explanations are presented in terms of first principles and basic physics, augmented by illustrative worked examples and numerous figures.

  11. Modern wiring practice

    CERN Document Server

    Steward, W E

    2012-01-01

    Continuously in print since 1952, Modern Wiring Practice has now been fully revised to provide an up-to-date source of reference to building services design and installation in the 21st century. This compact and practical guide addresses wiring systems design and electrical installation together in one volume, creating a comprehensive overview of the whole process for contractors and architects, as well as electricians and other installation engineers. Best practice is incorporated throughout, combining theory and practice with clear and accessible explanation, all

  12. Late Modern Play Culture

    DEFF Research Database (Denmark)

    Karoff, Helle Skovbjerg

    2008-01-01

    and the Danish University of Education (among others) have been working with different kind of products, all referred to as PlAYWARE. Playware combines modern technology and knowledge about play culture in order to produce playful experiences for its players. This paper will exemplify how the concept of play can...... from one generation to the next. Because older children are no longer present as younger children grow up, the traditional "cultural leaders" are gone. They have taken with them much of the inspiration for play as well as important knowledge about how to organise a game. In that sense we can say...

  13. Early modern mathematical instruments.

    Science.gov (United States)

    Bennett, Jim

    2011-12-01

    In considering the appropriate use of the terms "science" and "scientific instrument," tracing the history of "mathematical instruments" in the early modern period is offered as an illuminating alternative to the historian's natural instinct to follow the guiding lights of originality and innovation, even if the trail transgresses contemporary boundaries. The mathematical instrument was a well-defined category, shared across the academic, artisanal, and commercial aspects of instrumentation, and its narrative from the sixteenth to the eighteenth century was largely independent from other classes of device, in a period when a "scientific" instrument was unheard of.

  14. Modern dictionary of electronics

    CERN Document Server

    Graf, Rudolf F

    1999-01-01

    Included in this fully revised classic are well over 28,000 terms, phrases, acronyms, and abbreviations from the ever-expanding worlds of consumer electronics, optics, microelectronics, computers, communications, and medical electronics. From the basic elements of theory to the most cutting-edge circuit technology, this book explains it all in both words and pictures.For easy reference, the author has provided definitions for standard abbreviations and equations as well as tables of SI (International System of Units) units, measurements, and schematic symbolsModern Dictionary of Electronics is

  15. History as Modernity. Introduction

    Directory of Open Access Journals (Sweden)

    Pierangelo Schiera

    2016-12-01

    Full Text Available The introduction starts from the exhaustion of modernity, drawing the fundamental lines of its development inside Western historical experience. The end of the political nexus between theology and politics, the evanescence of nation-state sovereignty, the check of great historical interpretations reveal the necessity of new categories and new organizational models, able to make us answer to the violence that the ongoing processes are liberating. Schiera underlines in particular the relevance of the administrative apparatus because of its capacity to link the global government with global organization, human rights and the commons.

  16. Pinch grafting for chronic venous leg ulcers in general practice

    OpenAIRE

    Steele, Keith

    1985-01-01

    Twenty-five patients with chronic venous leg ulcers were treated in general practice by pinch grafting. Fifteen of the ulcers (60%) were completely healed one year after grafting. Prior to grafting 19 patients (76%) complained of daily pain in the ulcer. These patients experienced complete relief from pain after grafting. Pinch grafting is a simple, safe and effective therapy when applied in a domiciliary environment.

  17. Strategies to improve macroencapsulated islet graft survival

    OpenAIRE

    Sörenby, Anne

    2007-01-01

    Chronic immunosuppressive therapy may have severe side-effects. In cell transplantation, the graft can be encapsulated within a membrane chamber, providing a physical barrier against the immune system. The cell graft then becomes dependent on the diffusion of nutrients and oxygen from the surrounding microcirculation. A major drawback has been the formation of avascular fibrotic tissue around the chamber. The immunoprotective device studied (TheraCyte ) has an outer membrane...

  18. Surface modification of TiO2 nanotubes by grafting with APTS coupling agents

    Science.gov (United States)

    Phan Duong, Hong; Le, Minh Duc; Dao, Hung Cuong; Chen, Chia-Yun

    2017-10-01

    Titanium dioxide nanotubes (TNTs) have been considered the promising nanostructures employed for many practical applications such as biomedical, photonic and optoelectronic devices. Nevertheless, strong aggregation of TNTs within various aqueous media significantly hindered their practical utilizations and the capability of dispersing TNTs in the desired solvents are urgent to be improved. Therefore, in this study, the methodic investigations have been performed on the grafted modification of 3-aminopropyl triethoxysilane (APTS) on the surfaces of synthesized TNTs. A preliminary study was carried out to evaluate the influences of key parameters, including the concentrations of coupling agents, temperatures and the reaction durations, on the grafting efficiency of the aminosilane using Statistical design of experiments (DoE) methodology. TNTs with approximately 10-20 nm in diameter were prepared with the controlled hydrothermal treatment of commercialized P25 particles. The obtained products were revealed by the modern physicochemical systems including x-ray diffraction (XRD), transmission electron microscopy (TEM) and Brunauer-Emmett-Teller (BET) analysis. The additions of silane agent, reaction temperature and time have been adjusted to reveal the influences of the grafting efficiency (from 2.5 to 7.8 wt %) by thermal gravimetric analysis (TGA). Analysis of Fourier transform infrared spectroscopy (FTIR) has confirmed the successful link of Ti-O-Si chemical bonds on the grafted TNTs.

  19. Use of Chitosan-PVA Hydrogels with Copper Nanoparticles to Improve the Growth of Grafted Watermelon.

    Science.gov (United States)

    González Gómez, Homero; Ramírez Godina, Francisca; Ortega Ortiz, Hortensia; Benavides Mendoza, Adalberto; Robledo Torres, Valentín; Cabrera De la Fuente, Marcelino

    2017-06-22

    Modern agriculture requires alternative practices that improve crop growth without negatively affecting the environment, as resources such as water and arable land grow scarcer while the human population continues to increase. Grafting is a cultivation technique that allows the plant to be more efficient in its utilization of water and nutrients, while nanoscale material engineering provides the opportunity to use much smaller quantities of consumables compared to conventional systems but with similar or superior effects. On those grounds, we evaluated the effects of chitosan-polyvinyl alcohol hydrogel with absorbed copper nanoparticles (Cs-PVA-nCu) on leaf morphology and plant growth when applied to grafted watermelon cultivar 'Jubilee' plants. Stomatal density (SD), stomatal index (SI), stoma length (SL), and width (SW) were evaluated. The primary stem and root length, the stem diameter, specific leaf area, and fresh and dry weights were also recorded. Our results demonstrate that grafting induces modifications to leaf micromorphology that favorably affect plant growth, with grafted plants showing better vegetative growth in spite of their lower SD and SI values. Application of Cs-PVA-nCu was found to increase stoma width, primary stem length, and root length by 7%, 8% and 14%, respectively. These techniques modestly improve plant development and growth.

  20. Use of Chitosan-PVA Hydrogels with Copper Nanoparticles to Improve the Growth of Grafted Watermelon

    Directory of Open Access Journals (Sweden)

    Homero González Gómez

    2017-06-01

    Full Text Available Modern agriculture requires alternative practices that improve crop growth without negatively affecting the environment, as resources such as water and arable land grow scarcer while the human population continues to increase. Grafting is a cultivation technique that allows the plant to be more efficient in its utilization of water and nutrients, while nanoscale material engineering provides the opportunity to use much smaller quantities of consumables compared to conventional systems but with similar or superior effects. On those grounds, we evaluated the effects of chitosan-polyvinyl alcohol hydrogel with absorbed copper nanoparticles (Cs-PVA-nCu on leaf morphology and plant growth when applied to grafted watermelon cultivar ‘Jubilee’ plants. Stomatal density (SD, stomatal index (SI, stoma length (SL, and width (SW were evaluated. The primary stem and root length, the stem diameter, specific leaf area, and fresh and dry weights were also recorded. Our results demonstrate that grafting induces modifications to leaf micromorphology that favorably affect plant growth, with grafted plants showing better vegetative growth in spite of their lower SD and SI values. Application of Cs-PVA-nCu was found to increase stoma width, primary stem length, and root length by 7%, 8% and 14%, respectively. These techniques modestly improve plant development and growth.

  1. Local graft irradiation in renal transplant rejection

    International Nuclear Information System (INIS)

    Kawamura, Masashi; Kataoka, Masaaki; Itoh, Hisao

    1990-01-01

    From 1977 to 1988, of 142 renal transplantations, seven recipients (4.9%) received local graft irradiation following rejective reaction refractory to antirejection medical managements. Concurrent with the administration of pulsed high dose methylprednisolone and other antirejection medical managements, the graft was irradiated with a total dose of 6.0 Gy-150 cGy per fraction every other day at the midplane of the graft using two opposing portals of 4MX Linac. The fields were defined by palpation and echography. All patients had improvements in serum creatinine on the 10th day after beginning the irradiation. Four patients with peripheral lymphocytosis during the irradiation combined with pulsed high dose methylprednisolone improved in renal functions. On the other hand, out of 3 patients with lymphcytopenic changes, in two the transplanted graft was removed due to deteriorations, and the other patient is currently suffering from chronic rejection. Local graft irradiation can be useful in maintaining a rejective graft and reversing its functions in some patients whose rejective reaction failed to respond to the antirejection medical managements. (author)

  2. Graft-copolymerization onto carbon black

    International Nuclear Information System (INIS)

    Nakase, Yoshiaki; Nishii, Masanobu; Kijima, Toshiyuki; Kato, Hiroshi.

    1988-07-01

    Radiation-induced graft copolymerization of vinyl monomer onto carbon black was performed. During the γ-ray- and electron beam-induced polymerization (In-source), or the electron beam post-polymerization, the graft-copolymerization behavior was affected by the kinds of both carbon blacks and monomers, i.e. the smaller the size of carbon black particles, the higher the apparent grafted fraction. Homopolymer in the grafted carbon black samples was washed out by the solvent of the polymer, and the extracted polymer seemed to be dimer or trimer of the used monomer. In the case of the post-polymerization with the pre-irradiation doses of 50 Mrad, homopolymer was hardly observed. The polymer sheets of plastics or rubbers with grafted carbon black had an electrical conductivity unalterable considerably by the heating cycles. The particles of grafted carbon black in the sheet might be kept much more at the surface layer within 100 nm depth than at the inner layer. (author)

  3. Photoacoustic detection of neovascularities in skin graft

    Science.gov (United States)

    Yamazaki, Mutsuo; Sato, Shunichi; Saitoh, Daizo; Ishihara, Miya; Okada, Yoshiaki; Ashida, Hiroshi; Obara, Minoru

    2005-04-01

    We previously proposed a new method for monitoring adhesion of skin graft by measuring photoacoustic (PA) signal originated from the neovascularities. In this study, immunohistochemical staining (IHC) with CD31 antibody was performed for grafted skin tissue to observe neovascularity, and the results were compared with PA signals. We also used a laser Doppler imaging (LDI) to observe blood flow in the grafted skin, and sensitivity of PA measurement and that of LDI were compared. In rat autograft models, PA signals were measured for the grafted skin at postgrafting times of 0-48 h. At 6 h postgrafting, PA signal was observed in the skin depth region of 500-600 mm, while the results of IHC showed that angiogenesis occurred at the depth of about 600 mm. Depths at which PA signal and angiogenesis were observed decreased with postgrafting time. These indicate that the PA signal observed at 6 h postgrafting originated from the neovascularities in the skin graft. Results of LDI showed no blood-originated signal before 48 h postgrafting. These findings suggest that PA measurement is effective in monitoring the adhesion of skin graft in early stage after transplantation.

  4. Additive effects in radiation grafting and curing

    International Nuclear Information System (INIS)

    Viengkhou, V.; Ng, L.

    1996-01-01

    Full text: Detailed studies on the accelerative effect of novel additives in radiation grafting and curing using acrylated monomer/oligomer systems have been performed in the presence of ionising radiation and UV as sources. Methyl methacrylate (MMA) is used as typical monomer for these grafting studies in the presence of the additives with model backbone polymers, cellulose and propropylene. Additives which have been found to accelerate these grafting processes are: mineral acid, occlusion compounds like urea, thermal initiators and photoinitiators as well as multifunctional monomers such as multifunctional acrylates. The results from irradiation with gamma rays have also been compared with irradiation from a 90W UV lamp. The role of the above additives in accelerating the analogous process of radiation curing has been investigated. Acrylated urethanes, epoxies and polyesters are used as oligomers together with acrylated monomers in this work with uv lamps of 300 watts/inch as radiation source. In the UV curing process bonding between film and substrate is usually due to physical forces. In the present work the presence of additives are shown to influence the occurrence of concurrent grafting during cure thus affecting the nature of the bonding of the cured film. The conditions under which concurrent grafting with UV can occur will be examined. A mechanism for accelerative effect of these additives in both grafting and curing processes has been proposed involving radiation effects and partitioning phenomena

  5. Three-Dimensional Finite Element Analysis of Maxillary Sinus Floor Augmentation with Optimal Positioning of a Bone Graft Block

    Directory of Open Access Journals (Sweden)

    Peter Schuller-Götzburg

    2018-01-01

    Full Text Available Purpose: the aim of the computational 3D-finite element study is to evaluate the influence of an augmented sinus lift with additional inserted bone grafting. The bone graft block stabilizes the implant in conjunction with conventional bone augmentation. Two finite element models were applied: the real geometry based bone models and the simplified geometry models. The bone graft block was placed in three different positions. The implants were loaded first with an axial force and then with forces simulating laterotrusion and protrusion. This study examines whether the calculated stress behavior is symmetrical for both models. Having established a symmetry between the primary axis, the laterotrusion and protrusion behavior reduces calculation efforts, by simplifying the model. Material and Methods: a simplified U-shaped 3D finite element model of the molar region of the upper jaw and a more complex anatomical model of the left maxilla with less cortical bone were created. The bone graft block was placed in the maxillary sinus. Then the von Mises stress distribution was calculated and analyzed at three block positions: at contact with the sinus floor, in the middle of the implant helix and in the upper third of the implant. The two finite element models were then compared to simplify the modelling. Results: the position of the bone graft block significantly influences the magnitude of stress distribution. A bone graft block positioned in the upper third or middle of the implant reduces the quantity of stress compared to the reference model without a bone graft block. The low bone graft block position is clearly associated with lower stress distribution in compact bone. We registered no significant differences in stress in compact bone with regard to laterotrusion or protrusion. Conclusions: maximum values of von Mises stresses in compact bone can be reduced significantly by using a bone graft block. The reduction of stress is nearly the same for

  6. Plant Modernization Programs

    International Nuclear Information System (INIS)

    O'Hara, John

    2004-01-01

    Most nuclear plants were designed and built from the 1960's through the 1990's. These plants employ predominantly analog instrumentation and control (I and C) technology, and their control rooms are made up of primarily hardwired controls (e.g., switches, knobs and handles) and displays (e.g., gauges, linear scales and indicator lights). Over the past several years, these plants have been modernized with digital I and C and computer-based human-system interfaces (HSIs) such as software-based process controls, touch-screen interfaces and large-screen, overview displays. As these computer based HIS technologies are integrated into control rooms based on conventional technology, hybrid control rooms are created. The paper summarizes lessons learned from the study of plant modernization programs over the past ten years so that they can be used to help improve the modification process. While the research focused on the impact of technology change on human performance, a number of organizational and programmatic issues were observed as well. Eleven lessons learned are presented

  7. Modern introductory physics

    CERN Document Server

    Holbrow, Charles H; Amato, Joseph C; Galvez, Enrique; Parks, M. Elizabeth

    2010-01-01

    Modern Introductory Physics, 2nd Edition, by Charles H. Holbrow, James N. Lloyd, Joseph C. Amato, Enrique Galvez, and Beth Parks, is a successful innovative text for teaching introductory college and university physics. It is thematically organized to emphasize the physics that answers the fundamental question: Why do we believe in atoms and their properties?  The book provides a sound introduction to basic physical concepts with particular attention to the nineteenth- and twentieth-century physics underlying our modern ideas of atoms and their structure.  After a review of basic Newtonian mechanics, the book discusses early physical evidence that matter is made of atoms.  With a simple model of the atom Newtonian mechanics can explain the ideal gas laws, temperature, and viscosity.  Basic concepts of electricity and magnetism are introduced along with a more complicated model of the atom to account for the observed electrical properties of atoms. The physics of waves---particularly light and x-rays---an...

  8. The Multiple Modernities of Europe

    DEFF Research Database (Denmark)

    Thomassen, Bjørn

    What Europe? Eric Voegelin on the Mediterranean and the Atlantic modernities. The concept ‘multiple modernities’ has during the last decade established itself in social and political theory, not least due to contributions made by Shmul Eisenstadt. The debate on multiple moderntities has served...... to question certain eurocentric assumptions about modernity and has also reignited the question of European particularity in a world historical perspective. This paper will discuss how ‘Europe’ itself can be considered a result of (at least) two different modernities, as proposed by the political theorist......, Eric Voegelin. Eric Voegelin talked of two spatio-temporal specific modernities, the Mediterranean and the Atlantic modernities. In short, for Voegelin the Atlantic modernity with its breakthroughs in the 17th and 18th centuries was a specific figuration that should not be mistaken for ‘modernity...

  9. The Imaginary Significations of Modernity

    DEFF Research Database (Denmark)

    Carleheden, Mikael

    2010-01-01

    This article deals with the concept of modernity upon which one of the most interesting contemporary theories about modern social change is based - Peter Wagner's theory of successive modernities. Wagner understands modernity as a double imaginary signification which entails a basic tension between...... liberty and discipline. This conception is almost directly taken from Cornelius Castoriadis. I argue that this tension exists in two versions in Castoriadis' philosophy and that the two versions are incompatible. It is further claimed that the two versions reappear in Wagner's theory, which makes his...... theory of successive modernities partly inconsistent. A stance is taken for one of these versions and it is argued that the theory of successive modernities should appropriate that version as its point of departure in order to grasp the history of modernity in a consistent way. Keywords: Cornelius...

  10. Isotopic scintigraphy in kidney grafting

    International Nuclear Information System (INIS)

    Renfro, Richard.

    1976-01-01

    Isotopic explorations of kidney transplants were performed on sixty-six patients. Three scintigraphic techniques were used: labelled ferrous ascorbate scintigraphy, sequential 99m technetium DTPA scintigraphy and the 131 I hippuran nephrogram. The aim of this study is to analyse the results obtained under different pathological circumstances affecting the transplant, to discuss the advantages of the techniques and to propose a working procedure. The most reliable and accurate technique is the 131 I hippuran nephrogram combined with sequential 99mTc DTPA, by which renal vascularisation may be judged labelled ferrous ascorbate on the other hand is too insensitive. Although the information supplied is mostly contained in the scintigraphic images, the nephrographic curves and the blood radioactivity decay time and rad V/rad R ratio measurements are very helpful in the early diagnosis and differential diagnosis of complications affecting the transplant. The proper use of isotopic scintigraphy in kidney grafting should provide optimum conditions for better survival of the transplant at minimum risk to the patient [fr

  11. Role of graft oversizing in the fixation strength of barbed endovascular grafts.

    Science.gov (United States)

    Kratzberg, Jarin A; Golzarian, Jafar; Raghavan, Madhavan L

    2009-06-01

    The role of endovascular graft oversizing on risk of distal graft migration following endovascular aneurysm repair for abdominal aortic aneurysm is poorly understood. A controlled in vitro investigation of the role of oversizing in graft-aorta attachment strength for endovascular grafts (EVGs) with barbs was performed. Barbed stent grafts (N = 20) with controlled graft oversizing varying from 4-45% were fabricated while maintaining other design variables unchanged. A flow loop with physiological flow characteristics and a biosynthetic aortic aneurysm phantom (synthetic aneurysm model with a bovine aortic neck) were developed. The stent grafts were deployed into the aortic neck of the bio-synthetic aortic aneurysm phantom under realistic flow conditions. Computed tomography imaging of the graft-aorta complex was used to document attachment characteristics such as graft apposition, number of barbs penetrated, and penetration depth and angle. The strength of graft attachment to the aortic neck was assessed using mechanical pullout testing. Stent grafts were categorized into four groups based on oversizing: 4-10%; 11-20%; 21-30%; and greater than 30% oversizing. Pullout force, a measure of post-deployment fixation strength was not different between 4-10% (6.23 +/- 1.90 N), 11-20% (6.25 +/- 1.84 N) and 20-30% (5.85 +/- 1.89 N) groups, but significantly lower for the group with greater than 30% oversizing (3.67 +/- 1.41 N). Increasing oversizing caused a proportional decrease in the number of barbs penetrating the aortic wall (correlation = -0.83). Of the 14 barbs available in the stent graft, 89% of the barbs (12.5 of 14 on average) penetrated the aortic wall in the 4-10% oversizing group while only 38% (5.25 of 14) did for the greater than 30% group (P barb penetration were found to be positively correlated to pullout force. Greater than 30% graft oversizing affects both barb penetration and graft apposition adversely resulting in a low pullout force in this in vitro

  12. [Effects of slow twisting needle insertion and tubing needle insertion at Neiguan (PC 6) on cardiovascular function: a comparative study].

    Science.gov (United States)

    Ning, Shaoli; Zhao, Lihua; Xu, Lingjun; Huang, Yu; Pang, Yong; Huang, Dingjian

    2016-01-01

    To compare the effects between slow twisting needle insertion and tubing needle insertion. With cross-over design, 100 healthy young subjects (half male and half female) aged from 19 to 23 years were randomly divided into two groups by random digital table, 50 cases in each one. At the first stage, subjects in the group A were treated with slow twisting needle insertion while, subjects in,the group B were treated with tubing needle insertion. One week later, the procedure of second stage was performed alternately. The needle was inserted into Neiguan (PC 6) with two methods by one acupuncturist. The needle was retained for 5 min before removal. Five min before needle insertion as well as needle withdrawal and 30 min after needle withdrawal, ZXG-E automatic cardiovascular diagnostic apparatus was used to test cardiovascular function. At the tim of needle withdrawal, slow twisting needle insertion could improve effect work of kinetics (EWK), effective blood volume (BV) and reduce elastic expansion coefficient of blood vessel (FEK) and left ventricular spray blood impedance (VER), which was significantly different from tubing needle insertion (all P 0.05). The slow twisting needle insertion is significantly superior to tubing needle insertion on lowering vascular tension and VER, improving EWK and BV.

  13. Ocular inserts - Advancement in therapy of eye diseases

    Directory of Open Access Journals (Sweden)

    Anita Kumari

    2010-01-01

    Full Text Available The ocular insert represents a significant advancement in the therapy of eye disease. Ocular inserts are defined as sterile, thin, multilayered, drug-impregnated, solid or semisolid consistency devices placed into the cul-de-sac or conjuctival sac, whose size and shape are especially designed for ophthalmic application. They are composed of a polymeric support that may or may not contain a drug. The drug can later be incorporated as dispersion or a solution in the polymeric support. They offer several advantages as increased ocular residence and sustained release of medication into the eye. The insert includes a body portion sized to position within a lachrymal canaliculus of the eyelid. The inserts are classified according to their solubility as insoluble, soluble, or bioerodible inserts. The release of drug from the insert depends upon the diffusion, osmosis, and bioerosion of the drug, and this article is an attempt to present a brief about this newer drug delivery system.

  14. A nurse led peripherally inserted central catheter line insertion service is effective with radiological support

    International Nuclear Information System (INIS)

    Barber, Jonathan M.; Booth, Doris M.; King, Julia A.; Chakraverty, Sam

    2002-01-01

    AIM: Peripherally inserted central catheters (PICC) are increasingly used as a route of chemotherapy administration. Our aims were to assess a collaborative approach to PICC placement, with radiological support for a nurse led line insertion service in a minority of cases, and to determine whether PICC provided a safe and reliable method of chemotherapy administration. MATERIALS AND METHODS: Prospective data on 100 consecutive patients undergoing PICC placement for chemotherapy were collected. Lines were inserted by ward based nurses or under ultrasound guidance by radiologists. End points were successful completion of treatment or patient death. RESULTS: One hundred and forty-four lines were placed for 118 courses of chemotherapy. 107 (74%) were placed by nurses and 37 (26%) by radiologists. Ninety-five percent of patients completed therapy with either one or two lines. Seventy percent of lines were removed on achieving the primary end points. In two additional patients PICC could not be placed radiologically. Twelve patients were unable to complete treatment with PICC alone, nine of these required an alternative administration route. The catheter related sepsis rate was 4.9%. CONCLUSION: The majority of PICC can be successfully placed by trained nurses, reserving image guidance only for more difficult cases. PICC have an acceptable complication profile, and decrease the need for tunnelled central lines. Barber, J.M. et al. (2002)

  15. A bioinformatics approach for identifying transgene insertion sites using whole genome sequencing data.

    Science.gov (United States)

    Park, Doori; Park, Su-Hyun; Ban, Yong Wook; Kim, Youn Shic; Park, Kyoung-Cheul; Kim, Nam-Soo; Kim, Ju-Kon; Choi, Ik-Young

    2017-08-15

    Genetically modified crops (GM crops) have been developed to improve the agricultural traits of modern crop cultivars. Safety assessments of GM crops are of paramount importance in research at developmental stages and before releasing transgenic plants into the marketplace. Sequencing technology is developing rapidly, with higher output and labor efficiencies, and will eventually replace existing methods for the molecular characterization of genetically modified organisms. To detect the transgenic insertion locations in the three GM rice gnomes, Illumina sequencing reads are mapped and classified to the rice genome and plasmid sequence. The both mapped reads are classified to characterize the junction site between plant and transgene sequence by sequence alignment. Herein, we present a next generation sequencing (NGS)-based molecular characterization method, using transgenic rice plants SNU-Bt9-5, SNU-Bt9-30, and SNU-Bt9-109. Specifically, using bioinformatics tools, we detected the precise insertion locations and copy numbers of transfer DNA, genetic rearrangements, and the absence of backbone sequences, which were equivalent to results obtained from Southern blot analyses. NGS methods have been suggested as an effective means of characterizing and detecting transgenic insertion locations in genomes. Our results demonstrate the use of a combination of NGS technology and bioinformatics approaches that offers cost- and time-effective methods for assessing the safety of transgenic plants.

  16. Depth of the graft bed influences split-skin graft contraction.

    NARCIS (Netherlands)

    Mensik, I.; Lamme, E.N.; Brychta, P.

    2003-01-01

    Contraction of a split-thickness skin graft used for coverage of large defects remains a great problem in plastic, burn and reconstructive surgery. In this study we evaluated healing of split-thickness skin grafts transplanted in wounds on the subcutaneous fat and muscle fascia in pigs. Four young

  17. Ordinary and Activated Bone Grafts: Applied Classification and the Main Features

    Directory of Open Access Journals (Sweden)

    R. V. Deev

    2015-01-01

    Full Text Available Bone grafts are medical devices that are in high demand in clinical practice for substitution of bone defects and recovery of atrophic bone regions. Based on the analysis of the modern groups of bone grafts, the particularities of their composition, the mechanisms of their biological effects, and their therapeutic indications, applicable classification was proposed that separates the bone substitutes into “ordinary” and “activated.” The main differential criterion is the presence of biologically active components in the material that are standardized by qualitative and quantitative parameters: growth factors, cells, or gene constructions encoding growth factors. The pronounced osteoinductive and (or osteogenic properties of activated osteoplastic materials allow drawing upon their efficacy in the substitution of large bone defects.

  18. Making medieval art modern

    Directory of Open Access Journals (Sweden)

    Elizabeth den Hartog

    2015-12-01

    Full Text Available Janet T. Marquardt’s book ‘Zodiaque. Making medieval art modern’ discusses the historical context, history and impact of the Zodiaque publications issued by the monks from the abbey of Ste-Marie de la Pierre-qui-Vire in Burgundy between 1951 and 2001 and links the striking photogravures, the core business of these books, to the modern movement. Although Marquardt’s view that the Zodiaque series made a great impact on the study of Romanesque sculpture is somewhat overrated, her claim that the photogravures should be seen as avant-garde works of art and the books as a “museum without walls” is entirely convincing.

  19. Introduction to modern magnetohydrodynamics

    CERN Document Server

    Galtier, Sébastien

    2016-01-01

    Ninety-nine percent of ordinary matter in the Universe is in the form of ionized fluids, or plasmas. The study of the magnetic properties of such electrically conducting fluids, magnetohydrodynamics (MHD), has become a central theory in astrophysics, as well as in areas such as engineering and geophysics. This textbook offers a comprehensive introduction to MHD and its recent applications, in nature and in laboratory plasmas; from the machinery of the Sun and galaxies, to the cooling of nuclear reactors and the geodynamo. It exposes advanced undergraduate and graduate students to both classical and modern concepts, making them aware of current research and the ever-widening scope of MHD. Rigorous derivations within the text, supplemented by over 100 illustrations and followed by exercises and worked solutions at the end of each chapter, provide an engaging and practical introduction to the subject and an accessible route into this wide-ranging field.

  20. Parallelization in Modern C++

    CERN Multimedia

    CERN. Geneva

    2016-01-01

    The traditionally used and well established parallel programming models OpenMP and MPI are both targeting lower level parallelism and are meant to be as language agnostic as possible. For a long time, those models were the only widely available portable options for developing parallel C++ applications beyond using plain threads. This has strongly limited the optimization capabilities of compilers, has inhibited extensibility and genericity, and has restricted the use of those models together with other, modern higher level abstractions introduced by the C++11 and C++14 standards. The recent revival of interest in the industry and wider community for the C++ language has also spurred a remarkable amount of standardization proposals and technical specifications being developed. Those efforts however have so far failed to build a vision on how to seamlessly integrate various types of parallelism, such as iterative parallel execution, task-based parallelism, asynchronous many-task execution flows, continuation s...

  1. Breazeale Reactor Modernization Program

    International Nuclear Information System (INIS)

    Davison, C. C.

    2003-01-01

    The Penn State Breazeale Nuclear Reactor is the longest operating licensed research reactor in the nation. The facility has played a key role in educating scientists, engineers and in providing facilities and services to researchers in many different disciplines. In order to remain a viable and effective research and educational institution, a multi-phase modernization project was proposed. Phase I was the replacement of the 25-year old reactor control and safety system along with associated wiring and hardware. This phase was fully funded by non-federal funds. Tasks identified in Phases II-V expand upon and complement the work done in Phase I to strategically implement state-of-the-art technologies focusing on identified national needs and priorities of the future

  2. Modern atomic physics

    CERN Document Server

    Natarajan, Vasant

    2015-01-01

    Much of our understanding of physics in the last 30-plus years has come from research on atoms, photons, and their interactions. Collecting information previously scattered throughout the literature, Modern Atomic Physics provides students with one unified guide to contemporary developments in the field. After reviewing metrology and preliminary material, the text explains core areas of atomic physics. Important topics discussed include the spontaneous emission of radiation, stimulated transitions and the properties of gas, the physics and applications of resonance fluorescence, coherence, cooling and trapping of charged and neutral particles, and atomic beam magnetic resonance experiments. Covering standards, a different way of looking at a photon, stimulated radiation, and frequency combs, the appendices avoid jargon and use historical notes and personal anecdotes to make the topics accessible to non-atomic physics students. Written by a leader in atomic and optical physics, this text gives a state-of-the...

  3. Constructing tropical modernity

    Directory of Open Access Journals (Sweden)

    Antonio T. Díaz-Royo

    1995-07-01

    Full Text Available [First paragraph in part] The buildings and ruins we discover for ourselves hold a lasting place in our imagination, not to say in our affections. In a society that has neglected the formal treatment of "space," architecturally as well as in political terms, these personal discoveries can promote a subversion of sorts. Thus, the consecutive appearance of two volumes addressing the architecture produced at the turn of the century in Puerto Rico is a notable event. Each results from an architect's passionate concern with the advent of modernity. Thomas Marvel's book concentrates on the life and work of Antonin Nechodoma, an American of Bohemian origin who spent his most productive years in Puerto Rico. It is the result of his decades-long fascination with a "versatile architect, designer, and craftsman working in unusual circumstances" (p. xviii who left, both in Puerto Rico and in the Dominican Republic, a string of edifices strangely echoing the continental Prairie School.

  4. Answers to modernity

    DEFF Research Database (Denmark)

    Petersen, Karen Bjerg

    2008-01-01

    - teacher, learner or curriculum planner positions - result in different strategies or 'answers to modernity'. The research has taken place as a study of e-learning and virtual teachhing of Danish as a second language for adults. The fact that relations in virtual learning are established between physically......, locationally distant'. Based on a case study and interviews with e-learning teachers and learner participants in a virtual classroom setting and on extracts of the curriculum developed for the particular e-learning course, the aim of the paper is to discuss how different positions in an e-learning triangle...... absent individuals, who are locationnaly distant and may never meet, seems to necessitate different strategies towards e-learning, depending on the position in the learning triangle. The research results indicate, that teachers compensate for the disembedded social relations in e-llearning environments...

  5. Principles of modern physics

    CERN Document Server

    Saxena, A K

    2014-01-01

    Principles of Modern Physics, divided into twenty one chapters, begins with quantum ideas followed by discussions on special relativity, atomic structure, basic quantum mechanics, hydrogen atom (and Schrodinger equation) and periodic table, the three statistical distributions, X-rays, physics of solids, imperfections in crystals, magnetic properties of materials, superconductivity, Zeeman-, Stark- and Paschen Back- effects, Lasers, Nuclear physics (Yukawa's meson theory and various nuclear models), radioactivity and nuclear reactions, nuclear fission, fusion and plasma, particle accelerators and detectors, the universe, Elementary particles (classification, eight fold way and quark model, standard model and fundamental interactions), cosmic rays, deuteron problem in nuclear physics, and cathode ray oscilloscope. NEW TO THE FOURTH EDITION: The CO2 Laser Theory of magnetic moments on the basis of shell model Geological dating Laser Induced fusion and laser fusion reactor. Hawking radiation The cosmological red ...

  6. Physical properties of agave cellulose graft polymethyl methacrylate

    Energy Technology Data Exchange (ETDEWEB)

    Rosli, Noor Afizah; Ahmad, Ishak; Abdullah, Ibrahim; Anuar, Farah Hannan [Polymer Research Centre (PORCE), School of Chemical Sciences and Food Technology, Faculty of Science and Technology, Universiti Kebangsaan Malaysia, 43600 Bangi Selangor (Malaysia)

    2013-11-27

    The grafting polymerization of methyl methacrylate and Agave cellulose was prepared and their structural analysis and morphology were investigated. The grafting reaction was carried out in an aqueous medium using ceric ammonium nitrate as an initiator. The structural analysis of the graft copolymers was carried out by Fourier transform infrared and X-ray diffraction. The graft copolymers were also characterized by field emission scanning electron microscopy (FESEM). An additional peak at 1732 cm{sup −1} which was attributed to the C=O of ester stretching vibration of poly(methyl methacrylate), appeared in the spectrum of grafted Agave cellulose. A slight decrease of crystallinity index upon grafting was found from 0.74 to 0.68 for cellulose and grafted Agave cellulose, respectively. Another evidence of grafting showed in the FESEM observation, where the surface of the grafted cellulose was found to be roughed than the raw one.

  7. Insertion mechanics of bioinspired needles into soft tissues.

    Science.gov (United States)

    Sahlabadi, Mohammad; Khodaei, Seyedvahid; Jezler, Kyle; Hutapea, Parsaoran

    2017-12-22

    Most studies to date confirm that any increase in the needle insertion force increases the damage to the tissue. When it comes to brain tissue, even minor damage can cause a long-lasting traumatic brain injury. Thus there is a great demand for innovative minimally invasive needles among the medical community. In our previous studies a novel bioinspired needle design with specially designed barbs was used to perform insertion tests into Polyvinyl chloride (PVC) tissue-mimicking gels, in which it decreased the insertion force by as much as 25%. In this work, bioinspired needles were designed using a CAD software, and were then manufactured using a 3 D printer. The insertion tests into bovine brain and liver were then performed to further investigate the performance of our bioinspired needles in real tissues. Our results show that there was a 10-25% decrease in the insertion force for insertions into bovine brain, and a 35-45% reduction in the insertion force for insertions into bovine liver using the proposed bioinspired needles. The reduction in the insertion force is due to the decrease in the friction force of the bioinspired needle with the bovine tissues, and its results are consistent with our previous results.

  8. Single-copy insertion of transgenes in Caenorhabditis elegans

    DEFF Research Database (Denmark)

    Frøkjaer-Jensen, Christian; Davis, M Wayne; Hopkins, Christopher E

    2008-01-01

    developed a method that inserts a single copy of a transgene into a defined site. Mobilization of a Mos1 transposon generates a double-strand break in noncoding DNA. The break is repaired by copying DNA from an extrachromosomal template into the chromosomal site. Homozygous single-copy insertions can...... be obtained in less than 2 weeks by injecting approximately 20 worms. We have successfully inserted transgenes as long as 9 kb and verified that single copies are inserted at the targeted site. Single-copy transgenes are expressed at endogenous levels and can be expressed in the female and male germlines....

  9. Technical note: Computer-manufactured inserts for prosthetic sockets.

    Science.gov (United States)

    Sanders, Joan E; McLean, Jake B; Cagle, John C; Gardner, David W; Allyn, Katheryn J

    2016-08-01

    The objective of this research was to use computer-aided design software and a tabletop 3-D additive manufacturing system to design and fabricate custom plastic inserts for trans-tibial prosthesis users. Shape quality of inserts was tested right after they were inserted into participant's test sockets and again after four weeks of wear. Inserts remained properly positioned and intact throughout testing. Right after insertion the inserts caused the socket to be slightly under-sized, by a mean of 0.11mm, approximately 55% of the thickness of a nylon sheath. After four weeks of wear the under-sizing was less, averaging 0.03mm, approximately 15% of the thickness of a nylon sheath. Thus the inserts settled into the sockets over time. If existing prosthetic design software packages were enhanced to conduct insert design and to automatically generate fabrication files for manufacturing, then computer manufactured inserts may offer advantages over traditional methods in terms of speed of fabrication, ease of design, modification, and record keeping. Copyright © 2016 IPEM. Published by Elsevier Ltd. All rights reserved.

  10. Development of collimator insert for linac based stereotactic irradiation

    International Nuclear Information System (INIS)

    Singh, I.R.R.; Brindha, S.; Ravindran, B.P.; Rajshekhar, V.

    1999-01-01

    The aim of this study is to develop collimator inserts of various sizes which are either not commercially available or are expensive to import. The dosimetry parameters such as tissue maximum ratio (TMR), off-axis ratio (OAR) and output factor of the developed collimator insert are compared with that of the commercial collimator insert (Radionics). In order to check the suitability of the collimator insert developed locally for clinical use and to standardize the method of development, a collimator insert of 15 mm identical to the one supplied by Radionics is developed with low-melting alloy (Cerrobend). Moreover for the clinical use of the developed collimator insert, certain acceptance tests are performed which include a collimator concentricity test, beam size check and radiation leakage test. The dose verification is carried out with a thermoluminescent dosimeter ( 7 LiF rods) and an FBX chemical dosimeter in a human-head-shaped Perspex phantom filled with water. The variation between the calculated and measured dose is found to be within +2.4% for 7 LiF rods and -2.0% for the FBX chemical dosimeter thus ensuring the suitability of the developed collimator insert for clinical use. This has encouraged us to standardize the method adapted to develop the collimator insert and to develop collimator inserts of different field sizes. (author)

  11. Insertional Polymorphisms of Endogenous Feline Leukemia Viruses

    Science.gov (United States)

    Roca, Alfred L.; Nash, William G.; Menninger, Joan C.; Murphy, William J.; O'Brien, Stephen J.

    2005-01-01

    The number, chromosomal distribution, and insertional polymorphisms of endogenous feline leukemia viruses (enFeLVs) were determined in four domestic cats (Burmese, Egyptian Mau, Persian, and nonbreed) using fluorescent in situ hybridization and radiation hybrid mapping. Twenty-nine distinct enFeLV loci were detected across 12 of the 18 autosomes. Each cat carried enFeLV at only 9 to 16 of the loci, and many loci were heterozygous for presence of the provirus. Thus, an average of 19 autosomal copies of enFeLV were present per cat diploid genome. Only five of the autosomal enFeLV sites were present in all four cats, and at only one autosomal locus, B4q15, was enFeLV present in both homologues of all four cats. A single enFeLV occurred in the X chromosome of the Burmese cat, while three to five enFeLV proviruses occurred in each Y chromosome. The X chromosome and nine autosomal enFeLV loci were telomeric, suggesting that ectopic recombination between nonhomologous subtelomeres may contribute to enFeLV distribution. Since endogenous FeLVs may affect the infectiousness or pathogenicity of exogenous FeLVs, genomic variation in enFeLVs represents a candidate for genetic influences on FeLV leukemogenesis in cats. PMID:15767400

  12. Study on grafting glycidyl methacrylate onto HDPE membranes by pre-irradiation graft copolymerization

    International Nuclear Information System (INIS)

    Tong Long; Zu Jianhua; Liu Xinwen; Sun Guisheng; Yu Chunhui

    2006-01-01

    Glycidyl methacrylate (GMA) was grafted onto HDPE membranes by pre-irradiation method with 1.8 MeV E-beam and a kind of membranes having reactive epoxy groups was successfully synthesized. Effects of monomer concentration, reaction temperature and time and irradiation dose on the grafting yield were studied. Composition, thermo-property and surface morphology of the grafted membranes were studied by FTIR, DSC and Tapping-mode AFM, respectively. The FTIR measurements proved the synthesized copolymer is HDPE-g-GMA. The DSC results indicated the grafted HDPE's melting temperature (T m ) and heat of fusion (ΔH f ( HDPE) ) which was reduced with increasing grafting yield. The AFM images indicated that surface of the HDPE-g-GMA membranes was rougher than the virgin HDPE. (authors)

  13. Development of Highly Efficient Grafting Technique and Synthesis of Natural Polymer-Based Graft Adsorbent

    Energy Technology Data Exchange (ETDEWEB)

    Ueki, Y; Seko, N; Tamada, M [Japan Atomic Energy Agency, Quantum Beam Science Directorate, Takasaki (Japan)

    2012-09-15

    In the framework of the CRP, Japan has focused on the development of fibrous adsorbents for removal of toxic metal ions and recovery of significant metal ions from industrial wastewater and streaming water. Graft polymerization was carried out by using gamma irradiation facility and electron beam accelerator. Emulsion grafting is a novel topic for synthesis of metal ion adsorbents which are prepared from fibrous trunk polymers such as polyethylene fibre and biodegradable nonwoven fabrics. The emulsion grafting, where monomer micelles are dispersed in water in the presence of surfactant, is a highly efficient and economic grafting technique as compared to general organic solvent system. The resultant cotton-based adsorbent has high adsorption efficiency and high adsorption capacity for Hg, besides, it is biodegradable. Polylactic acid can also be used as a trunk material for the grafting. (author)

  14. Impact of bone graft harvesting techniques on bone formation and graft resorption

    DEFF Research Database (Denmark)

    Saulacic, Nikola; Bosshardt, Dieter D; Jensen, Simon S

    2015-01-01

    BACKGROUND: Harvesting techniques can affect cellular parameters of autogenous bone grafts in vitro. Whether these differences translate to in vivo bone formation, however, remains unknown. OBJECTIVE: The purpose of this study was to assess the impact of different harvesting techniques on bone fo......: Transplantation of autogenous bone particles harvested with four techniques in the present model resulted in moderate differences in terms of bone formation and graft resorption.......BACKGROUND: Harvesting techniques can affect cellular parameters of autogenous bone grafts in vitro. Whether these differences translate to in vivo bone formation, however, remains unknown. OBJECTIVE: The purpose of this study was to assess the impact of different harvesting techniques on bone...... formation and graft resorption in vivo. MATERIAL AND METHODS: Four harvesting techniques were used: (i) corticocancellous blocks particulated by a bone mill; (ii) bone scraper; (iii) piezosurgery; and (iv) bone slurry collected from a filter device upon drilling. The grafts were placed into bone defects...

  15. Buddhist Activism and Chinese Modernity

    Directory of Open Access Journals (Sweden)

    Hung-yok Ip

    2015-02-01

    Full Text Available The history of modern Chinese Buddhism has begun to attract attention in recent years. Some scholars have done inspiring research as they unravel the integration of Buddhism into the highly secularized process of Chinese modernity by drawing on the repository of knowledge on modern China. While this special issue joins this exciting endeavor, it also uses Buddhism as a window to reflect on scholarship on Chinese modernity. Conceptually, this special issue presses scholars in the field of modern China to rethink the place of tradition in the course of modernity. Thematically we show the expansionist impulse of Chinese Buddhism: In addition to envisioning the geographical expansion of their religion, Chinese Buddhists have endeavored to enhance the significance of Buddhism in various dimensions of Chinese society in particular and human life in general.

  16. Adolescent External Iliac Artery Trauma: Recurrent Aneurysmal Dilatation of an Iliofemoral Saphenous Vein Graft Treated by Stent-Grafting

    International Nuclear Information System (INIS)

    Lenton, James; Davies, John; Homer-Vanniasinkam, S.; McPherson, Simon

    2008-01-01

    An adolescent male sustained a severe penetrating injury to the external iliac artery. Emergency surgical revascularization was with a reversed long saphenous vein interposition graft. The primary graft and the subsequent revision graft both became aneurysmal. The second graft aneurysm was successfully excluded by endovascular stent-grafts with medium-term primary patency. A venous graft was used initially rather than a synthetic graft to reduce the risk of infection and the potential problems from future growth. Aneurysmal dilatation of venous grafts in children and adolescents is a rare but recognized complication. To the best of our knowledge, exclusion of these aneurysms with stent-grafts has not been previously reported in the adolescent population.

  17. Corneal graft reversal: Histopathologic report of two cases.

    Science.gov (United States)

    Qahtani, Abdullah A; Alkatan, Hind M

    2014-10-01

    Graft reversal is a rare cause for failed PKP. In this case report we are presenting 2 graft failure cases in which the corneal grafts were reversed unintentionally. The onset of signs of graft failure, however was variable. We have included their clinical course and the histopathologic findings of the removed corneal grafts. A total of 6 cases including ours have been reported so far. The aim of this report is to attract the attention of corneal surgeons to an additional rare cause for failed penetrating keratoplasty (PKP) which is donor graft reversal.

  18. Grafting of acrylamide onto synthetic co polyamide by gamma irradiation

    Energy Technology Data Exchange (ETDEWEB)

    Hamoud, M R; Qamhieyh, E A [Chemistry Dept., College of Ibn Al-Haitham Baghdad university-Adhamiyah-Baghdad- (Iraq)

    1995-10-01

    Grafted copolymer was prepared by using gamma irradiation to graft acrylamide onto polymeric molecule prepared by interfacial condensation between two diamine molecules like 1,2 diamino propane and 1,6 diamino-hexane in aqueous layer with sebacoyl chloride in organic layer. The resulted co polyamide was grafted with acrylamide using gamma irradiation. The optimum conditions of grafting reaction were found, also various factors such as the effect of solvents, redox systems and the role water on the radiochemical grafting were studied. Many techniques were used in the characterization of the copolymer before and after grafting. 8 figs.,.

  19. Characterization and Some Properties of Functionalized Graft Copolymer

    International Nuclear Information System (INIS)

    Hegazy El-Sayed, A.; Kamal, H.; Mahmoud, Gh.A.; Khalifa, N.A.

    2000-01-01

    The study involved the investigation and characterization of membranes prepared by graft copolymerization of acrylonitrile (AN) and vinyl acetate (VAc) binary monomers onto low density polyethylene (LDPE) and isotactic polypropylene (IPP). The mutual gamma-irradiation method was used as a grafting technique. The effects of grafting and chemical treatments on the thermal properties and crystallinity of prepared graft copolymer have been investigated using DSC, TGA and XRD. IR spectra recorded before and after grafting and also for the chemically treated membranes to elucidate the structural changes occurred due to grafting and chemical treatments

  20. Corneal Graft Rejection: Incidence and Risk Factors

    Directory of Open Access Journals (Sweden)

    Alireza Baradaran-Rafii

    2008-12-01

    Full Text Available

    PURPOSE: To determine the incidence and risk factors of late corneal graft rejection after penetrating keratoplasty (PKP. METHODS: Records of all patients who had undergone PKP from 2002 to 2004 without immunosuppressive therapy other than systemic steroids and with at least one year of follow up were reviewed. The role of possible risk factors such as demographic factors, other host factors, donor factors, indications for PKP as well as type of rejection were evaluated. RESULTS: During the study period, 295 PKPs were performed on 286 patients (176 male, 110 female. Mean age at the time of keratoplasty was 38±20 (range, 40 days to 90 years and mean follow up period was 20±10 (range 12-43 months. Graft rejection occurred in 94 eyes (31.8% at an average of 7.3±6 months (range, 20 days to 39 months after PKP. The most common type of rejection was endothelial (20.7%. Corneal vascularization, regrafting, anterior synechiae, irritating sutures, active inflammation, additional anterior segment procedures, history of trauma, uncontrolled glaucoma, prior graft rejection, recurrence of herpetic infection and eccentric grafting increased the rate of rejection. Patient age, donor size and bilateral transplantation had no significant influence on graft rejection. CONCLUSION: Significant risk factors for corneal graft rejection include

  1. Prediction of coronary artery bypass graft flow

    International Nuclear Information System (INIS)

    Tamiya, Eiji; Hada, Yoshiyuki; Asano, Ken-ichi; Iio, Masahiro.

    1991-01-01

    To predict the coronary artery bypass graft (CABG) flow based on the time density curve (TDC) obtained from the digital subtraction aortograms (DSA), we developed a pulsatile CABG model (perfusion pressure 60,130 mmHg, pulse rate 53,126/min, cardiac output 3-7 l/min, diameter of the graft 2.1∼6.0 mm). After positioning the regions of interest (ROI), we injected contrast medium(5∼40 ml/sec, 5∼40 ml) into the outlet conduit. Concerning the TDCs, we calculated appearance time (Ta), peak densities (Dp), peak time (Tp), disappearance time (Td), integral of TDC, ΔTp (difference of Tp between two ROI) and ΔTa (difference of Ta between two ROI). Perfusion pressure, graft flow and output curve were similar to those of patients with CABG. Ta, Tp, Td, and ΔTp were affected by both the injection rate and the volume of the contrast medium; while Dp and the TDC integral were only affected by the latter parameter. Under the same conditions of contrast medium injection, the TDC depended strongly on graft flow, diameter of the graft, output and pulse rate. 21.6+0.92π·d 2 /4·Δ1/ΔTp·60 provided the most accurate estimation of CABG flow (r=0.865, p<0.01). We conclude that densitometric analysis of DSA may be useful in the prediction of CABG flow. (author)

  2. Long-term results of PTFE grafts.

    Science.gov (United States)

    Hedin, Ulf

    2015-01-01

    Vascular surgeons are essential in "lifeline" creation for hemodialysis patients and should be the central player in any multidisciplinary access service together with nephrologists, dialysis staff and interventional radiology. In this position, access surgeons are involved in complicated clinical decision making regarding primary and secondary access selection, which throughout the last decade has been largely aided, and influenced, by national and international guidelines as well as other initiatives. These recommendations, unanimously and appropriately, advocate the placement of native fistulas over synthetic grafts (the majority grafts from expanded polytetrafluoroethylene, ePTFE, herein referred to as PTFE) based on the superiority of fistulas with respect to complications such as infections and thrombosis. Nevertheless, the use of PTFE grafts for hemodialysis access is an accepted and firmly established alternative to native fistulas where data today reveal unwanted consequences to overinterpretation of established guidelines such as increased catheter use. This information highlights a need for an adjustment of access selection strategies based on patient-centered algorithms. Here, available results on PTFE graft performance in hemodialysis access is recapitulated, with respect to both conventional grafts and technical modifications, and conclude with a modified approach to primary access selection.

  3. Frenuloplasty with a splitthicknes skin graft

    International Nuclear Information System (INIS)

    Mohammadi, G.; Nnaderpour, M.

    2006-01-01

    The purpose of this study was to investigate the severity of presenting symptomatology in patients with ankyloglossia and to assess the surgical results of patients undergoing frenuloplasty with split thickness skin graft. During a 4 year period from September 1998 through September 2002, 19 patients of ankyloglosia underwent frenuloplasty with a split thickness skin graft. All skin grafts were taken from arm. There were 11 males and 8 females. The average length of the lingual frenulum was 3.5 mm. Twelve children were over 4 years old and were primarily operated with this technique. In the 7 patients, Z plasty had been performed previously but failed and cicatrisation caused ankyloglosia. There were two minor postoperative complications, one hematoma, and other graft dehiscence with cicatrisation. The mobility of the tongue after one year was excellent. There were no complications in donor site. Frenuloplasty with split thickness skin graft is the best and easy procedure with good results for children over 4 years and those who fail primary closure. (author)

  4. Radiographic analysis of pasteurized autologous bone graft

    International Nuclear Information System (INIS)

    Ahmed, Adel Refaat; Manabe, Jun; Kawaguchi, Noriyoshi; Matsumoto, Seiichi; Matsushita, Yasushi

    2003-01-01

    Local malignant bone tumor excision followed by pasteurization and subsequent reimplantation is a unique technique for reconstruction after resection of primary bone sarcomas. The purpose of this investigation was to assess the normal and abnormal long-term radiographic findings of intercalary and osteo-chondral pasteurized bone graft/implant composite. The long-term radiographic findings of pasteurized bone grafts used in reconstruction after resection of bone and soft tissue sarcomas in relation to patients' clinical data were reviewed retrospectively. Thirty-one patients (18 females, 13 males; age range 7-77 years, mean 30 years) who underwent surgery between April 1990 and January 1997 at the authors' institute constituted the material of this study. They were followed up for at least 3 years or until the patient's death (mean 69 months). The International Society of Limb Salvage graft evaluation method that assesses the fusion, resorption, fracture, graft shortening, fixation, subluxation, joint narrowing and subchondral bone was used for evaluation of the radiographs. Twenty-one patients (68%) showed complete incorporation of graft and eight patients (26%) had partial incorporation. The overall radiographic evaluation rate was 81%. Fracture (10%) and infection (16%) were the main complications. No local recurrence was detected. These results indicate that pasteurization of bone is a useful option for reconstruction after resection of malignant bone tumors. (orig.)

  5. Aortic reconstruction with bovine pericardial grafts

    Directory of Open Access Journals (Sweden)

    Silveira Lindemberg Mota

    2003-01-01

    Full Text Available INTRODUCTION: Glutaraldehyde-treated crimped bovine pericardial grafts are currently used in aortic graft surgery. These conduits have become good options for these operations, available in different sizes and shapes and at a low cost. OBJECTIVE:To evaluate the results obtained with bovine pericardial grafts for aortic reconstruction, specially concerning late complications. METHOD: Between January 1995 and January 2002, 57 patients underwent different types of aortic reconstruction operations using bovine pericardial grafts. A total of 29 (50.8% were operated on an urgent basis (mostly acute Stanford A dissection and 28 electively. Thoracotomy was performed in three patients for descending aortic replacement (two patients and aortoplasty with a patch in one. All remaining 54 underwent sternotomy, cardiopulmonary bypass and aortic resection. Deep hypothermia and total circulatory arrest was used in acute dissections and arch operations. RESULTS: Hospital mortality was 17.5%. Follow-up was 24.09 months (18.5 to 29.8 months confidence interval and complication-free actuarial survival curve was 92.3% (standard deviation ± 10.6. Two patients lately developed thoracoabdominal aneurysms following previous DeBakey II dissection and one died from endocarditis. One "patch" aortoplasty patient developed local descending aortic pseudoaneurysm 42 months after surgery. All other patients are asymptomatic and currently clinically evaluated with echocardiography and CT scans, showing no complications. CONCLUSION: Use of bovine pericardial grafts in aortic reconstruction surgery is adequate and safe, with few complications related to the conduits.

  6. Radiographic analysis of pasteurized autologous bone graft

    Energy Technology Data Exchange (ETDEWEB)

    Ahmed, Adel Refaat [Department of Orthopedic Surgery, Cancer Institute Hospital, Japanese Foundation for Cancer Research, Kamiikebukuro 1-37-1, Toshima-ku, 170-0012, Tokyo (Japan); Department of Orthopedic Surgery, Alexandria University, Alexandria (Egypt); Manabe, Jun; Kawaguchi, Noriyoshi; Matsumoto, Seiichi; Matsushita, Yasushi [Department of Orthopedic Surgery, Cancer Institute Hospital, Japanese Foundation for Cancer Research, Kamiikebukuro 1-37-1, Toshima-ku, 170-0012, Tokyo (Japan)

    2003-08-01

    Local malignant bone tumor excision followed by pasteurization and subsequent reimplantation is a unique technique for reconstruction after resection of primary bone sarcomas. The purpose of this investigation was to assess the normal and abnormal long-term radiographic findings of intercalary and osteo-chondral pasteurized bone graft/implant composite. The long-term radiographic findings of pasteurized bone grafts used in reconstruction after resection of bone and soft tissue sarcomas in relation to patients' clinical data were reviewed retrospectively. Thirty-one patients (18 females, 13 males; age range 7-77 years, mean 30 years) who underwent surgery between April 1990 and January 1997 at the authors' institute constituted the material of this study. They were followed up for at least 3 years or until the patient's death (mean 69 months). The International Society of Limb Salvage graft evaluation method that assesses the fusion, resorption, fracture, graft shortening, fixation, subluxation, joint narrowing and subchondral bone was used for evaluation of the radiographs. Twenty-one patients (68%) showed complete incorporation of graft and eight patients (26%) had partial incorporation. The overall radiographic evaluation rate was 81%. Fracture (10%) and infection (16%) were the main complications. No local recurrence was detected. These results indicate that pasteurization of bone is a useful option for reconstruction after resection of malignant bone tumors. (orig.)

  7. Penile Inversion Vaginoplasty with or without Additional Full-Thickness Skin Graft: To Graft or Not to Graft?

    Science.gov (United States)

    Buncamper, Marlon E; van der Sluis, Wouter B; de Vries, Max; Witte, Birgit I; Bouman, Mark-Bram; Mullender, Margriet G

    2017-03-01

    Penile inversion vaginoplasty is considered to be the gold standard for gender reassignment surgery in transgender women. The use of additional full-thickness skin graft as neovaginal lining is controversial. Some believe that having extra penile skin for the vulva gives better aesthetic results. Others believe that it gives inferior functional results because of insensitivity and skin graft contraction. Transgender women undergoing penile inversion vaginoplasty were studied prospectively. The option to add full-thickness skin graft is offered in patients where the penile skin length lies between 7 and 12 cm. Neovaginal depth was measured at surgery and during follow-up (3, 13, 26, and 52 weeks postoperatively). Satisfaction with the aesthetic result, neovaginal depth, and dilation regimen during follow-up were recorded. Satisfaction, sexual function, and genital self-image were assessed using questionnaires. A total of 100 patients were included (32 with and 68 without additional full-thickness skin graft). Patient-reported aesthetic outcome, overall satisfaction with the neovagina, sexual function, and genital self-image were not significantly associated with surgical technique. The mean intraoperative neovaginal depth was 13.8 ± 1.4 cm. After 1 year, this was 11.5 ± 2.5 cm. The largest decline (-15 percent) in depth is observed in the first 3 postoperative weeks (p skin graft use, in penile inversion vaginoplasty. The additional use of full-thickness skin graft does not influence neovaginal shrinkage, nor does it affect the patient- and physician-reported aesthetic or functional outcome. Therapeutic, IV.

  8. Clinical information in drug package inserts in India

    Directory of Open Access Journals (Sweden)

    Shivkar Y

    2009-01-01

    Full Text Available Background: It is widely recognized that accurate and reliable product information is essential for the safe and effective use of medications. Pharmaceutical companies are the primary source of most drug information, including package inserts. Package inserts are printed leaflets accompanying marketed drug products and contain information approved by the regulatory agencies. Studies on package inserts in India, in 1996, had shown that crucial information was often missing and they lacked uniformity. Aim: To assess the presentation and completeness of clinically important information provided in the currently available package inserts in India. Materials and Methods: Package inserts accompanying allopathic drug products marketed by pharmaceutical companies in India were collected. These package inserts were analyzed for the content of clinically important information in various sections. Statistical Analysis: The results were expressed as absolute numbers and percentages. Results: Preliminary analyses revealed that most package inserts did contain information under headings, such as, therapeutic indications, contraindications, undesirable effects, etc., listed in the Drugs and Cosmetics Rules 1945. The findings indicated considerable improvement in package inserts since 1996. However, on critical evaluation it was revealed that clinically important information was not well presented and was often incomplete. Information with regard to pediatric and geriatric use was present in only 44% and 13% of the package inserts, respectively. Only five of the inserts had information on the most frequent adverse drug reactions associated with the drug. Also, information on interactions and overdosage was often missing. Conclusion: Although the package inserts appear to have improved over the past decade there is still a definite need to further refine the clinical information contained, to minimize the risks to patients. This could be brought about by self

  9. A COMPARATIVE STUDY OF TYMPANOPLASTY USING SLICED CARTILAGE GRAFT VS. TEMPORALIS FASCIA GRAFT

    Directory of Open Access Journals (Sweden)

    Rahul Ashok Telang

    2018-02-01

    Full Text Available BACKGROUND The objective of the study was to compare the hearing improvement after using sliced cartilage graft with that of temporalis fascia and to compare the graft take-up between the two graft materials. MATERIALS AND METHODS A prospective clinical study including 60 patients with chronic mucosal otitis media, who were selected randomly from the outpatient department, after obtaining their consent were divided into 2 groups of 30 each, and evaluated according the study protocol. Their pre-operative audiometry was recorded and both groups of patients underwent surgery with one of the graft materials- temporalis fascia or sliced tragal cartilage with a thickness of 0.5 mm. All patients were regularly followed up and post-operative audiometry was done at 3 months. The hearing improvement in the form of closure of air-bone-gap and graft take-up was analysed statistically. RESULTS The temporalis fascia graft group had a pre-operative ABG of 22.33 ± 6.24 dB and post-operative ABG of 12.33 ± 4.72 dB with hearing improvement of 10.00 dB. The sliced cartilage graft group had a pre-operative ABG of 20.77 ± 5.75 dB and postoperative ABG of 10.50 ± 4.46 dB with hearing improvement of 10.27 dB. In the temporalis fascia group, 28 (93.3% patients had good graft take-up and in the sliced cartilage group 29 (96.7% had good graft take-up. There was statistically significant hearing improvement in both of our study groups but there was no statistically significant difference between the two groups. There was no statistically significant difference in graft take-up also. CONCLUSION Sliced cartilage graft is a good auto-graft material in tympanoplasty, which can give good hearing improvement and has good graft take-up, which is comparable with that of temporalis fascia.

  10. Characterization of the relationship between APOBEC3B deletion and ACE Alu insertion.

    Directory of Open Access Journals (Sweden)

    Kang Wang

    Full Text Available The insertion/deletion (I/D polymorphism of the angiotensin converting enzyme (ACE, commonly associated with many diseases, is believed to have affected human adaptation to environmental changes during the out-of-Africa expansion. APOBEC3B (A3B, a member of the cytidine deaminase family APOBEC3s, also exhibits a variable gene insertion/deletion polymorphism across world populations. Using data available from published reports, we examined the global geographic distribution of ACE and A3B genotypes. In tracking the modern human dispersal routes of these two genes, we found that the variation trends of the two I/D polymorphisms were directly correlated. We observed that the frequencies of ACE insertion and A3B deletion rose in parallel along the expansion route. To investigate the presence of a correlation between the two polymorphisms and the effect of their interaction on human health, we analyzed 1199 unrelated Chinese adults to determine their genotypes and other important clinical characteristics. We discovered a significant difference between the ACE genotype/allele distribution in the A3B DD and A3B II/ID groups (P = 0.045 and 0.015, respectively, indicating that the ACE Alu I allele frequency in the former group was higher than in the latter group. No specific clinical phenotype could be associated with the interaction between the ACE and A3B I/D polymorphisms. A3B has been identified as a powerful inhibitor of Alu retrotransposition, and primate A3 genes have undergone strong positive selection (and expansion for restricting the mobility of endogenous retrotransposons during evolution. Based on these findings, we suggest that the ACE Alu insertion was enabled (facilitated by the A3B deletion and that functional loss of A3B provided an opportunity for enhanced human adaptability and survival in response to the environmental and climate challenges arising during the migration from Africa.

  11. Ultrasonic Guided Insertion of Central Venous Catheter in Infants ...

    African Journals Online (AJOL)

    Background/Purpose: ultrasound is licensed for application of regional blocks and insertion of vascular access. We aimed to compare ultrasonic guided (USG) and anatomical landmark technique (ALT) for insertion of central venous catheter (CVC) as regard success rate and rate of complications in infants and children.

  12. Enhanced citrate production through gene insertion in Aspergillus niger

    DEFF Research Database (Denmark)

    Jongh, Wian de; Nielsen, Jens

    2007-01-01

    The effect of inserting genes involved in the reductive branch of the tricarboxylic acid (TCA) cycle on citrate production by Aspergillus niger was evaluated. Several different genes were inserted individually and in combination, i.e. malate dehydrogenase (mdh2) from Saccharomyces cerevisiae, two...

  13. Load beam unit replaceable inserts for dry coal extrusion pumps

    Science.gov (United States)

    Saunders, Timothy; Brady, John D.

    2012-11-13

    A track assembly for a particulate material extrusion pump according to an exemplary aspect of the present disclosure includes a link assembly with a roller bearing. An insert mounted to a load beam located such that the roller bearing contacts the insert.

  14. Forward and reverse genetics: The LORE1 retrotransposon insertion mutants

    DEFF Research Database (Denmark)

    Fukai, Eigo; Malolepszy, Anna; Sandal, Niels Nørgaard

    2014-01-01

    The endogenous Lotus retrotransposon 1 (LORE1) transposes in the germ line of Lotus japonicus plants that carry an active element. This feature of LORE1 has been exploited for generation of a large non-transgenic insertion mutant population, where insertions have been annotated using next-generat...

  15. Moderne nordiske maskulinitetsidealer?

    DEFF Research Database (Denmark)

    Jensen, Sune Qvotrup; Bloksgaard, Lotte; Christensen, Ann-Dorte

    en dansk/nordisk sammenhæng (n=50). Fokusgruppeinterviewene er gennemført i forbindelse med forskningsprojektet ”MARS – Mænd, arbejdsulykker og sikkerhed” (se yderligere: http://www.soc.aau.dk/forskning/mars/forside). Formålet med MARS-projektet er at undersøge, hvorvidt og hvordan der kan være en......, men snarere ofte konstitueres i en brydning mellem traditionelle maskulinitetsidealer og moderne maskulinitetsidealer. Denne brydning er igen præget af den danske/nordiske kontekst, hvor ligestilling i en årrække har været på den politiske dagsorden og hvor mænd i stigende grad deltager i...... knyttet til klasse, alder, geografisk kontekst. Dette peger på det væsentlige i at inddrage et intersektionalitetsperspektiv, når man skal forstå/diskutere maskulinitetsidealer. Eftersom der er tale om et skævt sample, er der grænser for, hvor vidtrækkende man kan konkludere på analysen af MARS...

  16. Zeno Meets Modern Science

    Science.gov (United States)

    Silagadze, Z. K.

    2005-10-01

    ``No one has ever touched Zeno without refuting him''. We will not refute Zeno in this paper. Instead we review some unexpected encounters of Zeno with modern science. The paper begins with a brief biography of Zeno of Elea followed by his famous paradoxes of motion. Reflections on continuity of space and time lead us to Banach and Tarski and to their celebrated paradox, which is in fact not a paradox at all but a strict mathematical theorem, although very counterintuitive. Quantum mechanics brings another flavour in Zeno paradoxes. Quantum Zeno and anti-Zeno effects are really paradoxical but now experimental facts. Then we discuss supertasks and bifurcated supertasks. The concept of localisation leads us to Newton and Wigner and to interesting phenomenon of quantum revivals. At last we note that the paradoxical idea of timeless universe, defended by Zeno and Parmenides at ancient times, is still alive in quantum gravity. The list of references that follows is necessarily incomplete but we hope it will assist interested reader to fill in details.

  17. Modern community care program

    International Nuclear Information System (INIS)

    Nordin, Staffan

    2000-01-01

    Going into the next millennium do we see nuclear energy? Yes we will see an expanding nuclear sector in the modem community. he modem community that cares for people, health and environment needs nuclear. Energy saves lives. Electricity is efficient use of energy. Energy will be the key to a sustainable society, energy is life. Nuclear energy protects the environment. Nuclear is an integral part of the modern community caring for people, health and environment. The dynamics of the public opinion-forming process and its effects on the nuclear industry are a challenge of the global nuclear industry. Current communications strategy and its consequences are on of the key issues. The nuclear industry must be perceived in certain ways in order to move towards achieving the vision and avoiding the harassment scenario. Each perception goal does not bear the same function within the communications process. As the nuclear industry is oe of the keys to a sustainable society, it must achieve legitimacy in its capacity as an interesting agenda-setter for tackling problems and as an expert. We have to build our communication activities on an open and honest attitude and we have to establish trust and confidence. The nuclear industry must also prove its ability and performance. If this could be achieved there will be an option for the future

  18. Modern Fourier analysis

    CERN Document Server

    Grafakos, Loukas

    2014-01-01

    This text is addressed to graduate students in mathematics and to interested researchers who wish to acquire an in depth understanding of Euclidean Harmonic analysis. The text covers modern topics and techniques in function spaces, atomic decompositions, singular integrals of nonconvolution type, and the boundedness and convergence of Fourier series and integrals. The exposition and style are designed to stimulate further study and promote research. Historical information and references are included at the end of each chapter. This third edition includes a new chapter entitled "Multilinear Harmonic Analysis" which focuses on topics related to multilinear operators and their applications. Sections 1.1 and 1.2 are also new in this edition. Numerous corrections have been made to the text from the previous editions and several improvements have been incorporated, such as the adoption of clear and elegant statements. A few more exercises have been added with relevant hints when necessary. Reviews fr...

  19. Modern graph theory

    CERN Document Server

    Bollobás, Béla

    1998-01-01

    The time has now come when graph theory should be part of the education of every serious student of mathematics and computer science, both for its own sake and to enhance the appreciation of mathematics as a whole. This book is an in-depth account of graph theory, written with such a student in mind; it reflects the current state of the subject and emphasizes connections with other branches of pure mathematics. The volume grew out of the author's earlier book, Graph Theory -- An Introductory Course, but its length is well over twice that of its predecessor, allowing it to reveal many exciting new developments in the subject. Recognizing that graph theory is one of several courses competing for the attention of a student, the book contains extensive descriptive passages designed to convey the flavor of the subject and to arouse interest. In addition to a modern treatment of the classical areas of graph theory such as coloring, matching, extremal theory, and algebraic graph theory, the book presents a detailed ...

  20. [Localized purpura revealing vascular prosthetic graft infection].

    Science.gov (United States)

    Boureau, A S; Lescalie, F; Cassagnau, E; Clairand, R; Connault, J

    2013-07-01

    Prosthetic graft infection after vascular reconstruction is a rare but serious complication. We report a case of infection occurring late after implantation of an iliofemoral prosthetic vascular graft. The Staphylococcus aureus infection was revealed by vascular purpura localized on the right leg 7 years after implantation of a vascular prosthesis. This case illustrates an uncommonly late clinical manifestation presenting as an acute infection 7 years after the primary operation. In this situation, the presentation differs from early infection, which generally occurs within the first four postoperative months. Diagnosis and treatment remain a difficult challenge because prosthetic graft infection is a potentially life-threatening complication. Morbidity and mortality rates are high. Here we detail specific aspects of the clinical and radiological presentation. Copyright © 2013 Elsevier Masson SAS. All rights reserved.

  1. Meshed split skin graft for extensive vitiligo

    Directory of Open Access Journals (Sweden)

    Srinivas C

    2004-05-01

    Full Text Available A 30 year old female presented with generalized stable vitiligo involving large areas of the body. Since large areas were to be treated it was decided to do meshed split skin graft. A phototoxic blister over recipient site was induced by applying 8 MOP solution followed by exposure to UVA. The split skin graft was harvested from donor area by Padgett dermatome which was meshed by an ampligreffe to increase the size of the graft by 4 times. Significant pigmentation of the depigmented skin was seen after 5 months. This procedure helps to cover large recipient areas, when pigmented donor skin is limited with minimal risk of scarring. Phototoxic blister enables easy separation of epidermis thus saving time required for dermabrasion from recipient site.

  2. [Vascular trombosis of renal graft: 9 cases].

    Science.gov (United States)

    Kaaroud, Hayet; Béji, Soumaya; Ben Hamida, Fethi; Rais, Lamia; Ben Abdallah, Taieb; El Younsi, Fethi; Ben Moussa, Fatma; Abderrahim, Ezzedine; Bardi, Rafika; Ayed, Khaled; Chebil, Mohamed; Kheder, Adel

    2008-04-01

    Allograft renal thrombosis can occur in 1 to 6% of cases. Many predisposing factors has been identified especially alteration of coagulation. We analyzed in this study frequency and predisposing factors of renal graft thrombosis. We report a retrospective study including 319 renal transplant recipients. Nine patients (2.8%) presented veinous graft thrombosis in 5 cases and arterial thombosis in 4 cases. There were 6 men and 3 women aged of 30.6 years meanly (10-56) which developed the thrombosis 6 days (1-48) after the transplantation. All patients were detransplanted after 16.2 days and 1 patient died. Thrombosis constitute an important cause of graft loss. A perfect surgical technic and prophylactic treatment in high risk patients are necessary to reduce this complication.

  3. Cartilage grafting in facial reconstruction with special consideration of irradiated grafts

    International Nuclear Information System (INIS)

    Donald, P.J.

    1986-01-01

    The search for the perfect facial implant for reconstruction of the face continues. Cartilage, once thought to be an undesirable graft material because of its propensity for absorption, has regained popularity in the past decade. Various preparation techniques have been employed to ensure graft sterility and diminished absorption. An improved understanding of cartilage structure and physiology has shed considerable light on the host-graft relationship. Gamma irradiation is a time-honored method of preservation. An experiment was undertaken to investigate the physiology of irradiated cartilage grafts following prolonged implantation on the facial skeleton of sheep and dog. Merthiolate preserved grafts were used as controls. Direct observation, histochemical techniques, autoradiography, and transmission electron micrography were used to determine chondrocyte viability and matrix composition. It was surprising to note that following implantation of 16 to 72 months, complete resorption was seen in 87.7% of the irradiated grafts and in 43.8% of the Merthiolate stored controls. Many of the grafts acquired chondrocytes from the host and produced new proteoglycan matrix as well as undergoing some degree of ossification. A comparison to the clinical situation in humans is made. 98 references

  4. Periotest values of implants placed in sockets augmented with calcium phosphosilicate putty graft: a comparative analysis against implants placed in naturally healed sockets.

    Science.gov (United States)

    Mahesh, Lanka; Narayan, Tv; Kostakis, Georgios; Shukla, Sagrika

    2014-03-01

    To measure implant stability using periotest values of implants placed in sockets augmented with calcium phospho-silicate putty (CPS Putty) as compared with implant stability in naturally healed sockets. Twenty two sockets were implanted with CPS Putty immediately after extraction. The sockets were re-entered after a healing period at 5 to 6 months (average 5.3 months) for implant placement. Periotest values were recorded during implant insertion to assess primary stability. These were compared with the Periotest values of 26 implants placed in 22 patients, with naturally healed sockets. Periotest values were significantly lower in the grafted group, indicating better implant stability in sites grafted with CPS putty. Implant stability seems to be significantly higher in sockets augmented using CPS putty when compared to nongrafted sites. This suggests that socket grafting with CPS putty may enhance the quality of available bone for implantation.

  5. Primary nerve grafting: A study of revascularization.

    Science.gov (United States)

    Chalfoun, Charbel; Scholz, Thomas; Cole, Matthew D; Steward, Earl; Vanderkam, Victoria; Evans, Gregory R D

    2003-01-01

    It was the purpose of this study to evaluate the revascularization of primary nerve repair and grafts using orthogonal polarization spectral (OPS) (Cytometrix, Inc.) imaging, a novel method for real-time evaluation of microcirculatory blood flow. Twenty male Sprague Dawley rats (250 g) were anesthetized with vaporized halothane and surgically prepared for common peroneal nerve resection. Group I animals (n = 10) underwent primary neurorraphy following transection, utilizing a microsurgical technique with 10-0 nylon suture. Group II (n = 10) animals had a 7-mm segment of nerve excised, reversed, and subsequently replaced as a nerve graft under similar techniques. All animals were evaluated using the OPS imaging system on three portions (proximal, transection site/graft, and distal) of the nerve following repair or grafting. Reevaluation of 5 animals randomly selected from each group using the OPS imaging system was again performed on days 14 and 28 following microsurgical repair/grafting. Values were determined by percent change in vascularity of the common peroneal nerve at 0 hr following surgery. Real-time evaluation of blood flow was utilized as an additional objective criterion. Percent vascularity in group I and II animals increased from baseline in all segments at day 14. By day 28, vascularity in nerves of group I rats decreased in all segments to values below baseline, with the exception of the transection site, which remained at a higher value than obtained directly after surgical repair. In group II animals, vascularity remained above baseline in all segments except the distal segment, which returned to vascularity levels similar to those at 0 hr. Further, occlusion of the vessels demonstrated in the graft and distal segments following initial transection appeared to be corrected. This study suggests that revascularization may occur via bidirectional inosculation with favored proximal vascular growth advancement. The use of real-time imaging offers a

  6. Treatment of hilar cholangiocarcinoma with inserting biliary double stents

    International Nuclear Information System (INIS)

    Jia Guangzhi; Zhang Zidong; Wang Xuejing; Yin Hua; Li Jianming

    2004-01-01

    Objective: To investigate the inserting technique of biliary double stents in treating hilar cholangiocarcinoma. Methods: 6 patients with hilar cholangiocarcinoma (Bismuth IV) were treated by percutaneous transhepatic insertion of biliary stents. Double stents were inserted in each patient. Different inserting methods were adopted according to the branch angles formed by left and right hepatic ducts. Results: The jaundice of all patients alleviated or disappeared obviously after stent implantation. The average difference between post-and pre-operation in the serum total bilirubin level was (104 ± 29) μmol/L (P<0.01). Stent obstruction was found in 2 cases after 4 and 6 months respectively. Conclusion: Double stents implantation is effective for the treatment of hilar cholangiocarcinoma. Beware of the angulation between main hepatic duct and adopting different inserting methods. (authors)

  7. Additive Manufacturing for Highly Efficient Window Inserts CRADA Report

    Energy Technology Data Exchange (ETDEWEB)

    Roschli, Alex C. [ORNL; Chesser, Phillip C. [ORNL; Love, Lonnie J. [ORNL

    2018-04-01

    ORNL partnered with the Mackinac Technology Company to demonstrate how additive manufacturing can be used to create highly energy efficient window inserts for retrofit in pre-existing buildings. Many early iterations of the window inserts were fabricated using carbon fiber reinforced thermoplastics and polycarbonate films as a stand in for the low-e coated films produced by the Mackinac Technology Company. After demonstration of the proof of concept, i.e. custom window inserts with tensioned film, the materials used for the manufacture of the frames was more closely examined. Hollow particle-filled syntactic foam and low-density polymer composites formed by expandable microspheres were explored as the materials used to additively manufacture the frames of the inserts. It was concluded that low-cost retrofit window inserts in custom sizes could be easily fabricated using large scale additive manufacturing. Furthermore, the syntactic and expanded foams developed and tested satisfy the mechanical performance requirements for the application.

  8. Turbine airfoil having near-wall cooling insert

    Science.gov (United States)

    Martin, Jr., Nicholas F.; Wiebe, David J.

    2017-09-12

    A turbine airfoil is provided with at least one insert positioned in a cavity in an airfoil interior. The insert extends along a span-wise extent of the turbine airfoil and includes first and second opposite faces. A first near-wall cooling channel is defined between the first face and a pressure sidewall of an airfoil outer wall. A second near-wall cooling channel is defined between the second face and a suction sidewall of the airfoil outer wall. The insert is configured to occupy an inactive volume in the airfoil interior so as to displace a coolant flow in the cavity toward the first and second near-wall cooling channels. A locating feature engages the insert with the outer wall for supporting the insert in position. The locating feature is configured to control flow of the coolant through the first or second near-wall cooling channel.

  9. Coronary Artery Bypass Graft Surgery: The Past, Present, and Future of Myocardial Revascularisation

    Directory of Open Access Journals (Sweden)

    Michael Diodato

    2014-01-01

    Full Text Available The development of the heart-lung machine ushered in the era of modern cardiac surgery. Coronary artery bypass graft surgery (CABG remains the most common operation performed by cardiac surgeons today. From its infancy in the 1950s till today, CABG has undergone many developments both technically and clinically. Improvements in intraoperative technique and perioperative care have led to CABG being offered to a more broad patient profile with less complications and adverse events. Our review outlines the rich history and promising future of myocardial revascularization.

  10. Infolding of fenestrated endovascular stent graft.

    Science.gov (United States)

    Zelt, Jason G E; Jetty, Prasad; Hadziomerovic, Adnan; Nagpal, Sudhir

    2017-09-01

    We report a case of infolding of a fenestrated stent graft involving the visceral vessel segment after a juxtarenal abdominal aorta aneurysm repair. The patient remains free of any significant endoleak, and the aortic sac has shown regression. The patient remains asymptomatic, with no abdominal pain, with normal renal function, and without ischemic limb complications. We hypothesize that significant graft oversizing (20%-30%) with asymmetric engineering of the diameter-reducing ties may have contributed to the infolding. Because of the patient's asymptomatic nature and general medical comorbidities, further intervention was deemed inappropriate as the aneurysmal sac is regressing despite the infolding.

  11. Expanded polytetrafluoroethylene graft fistula for chronic hemodialysis.

    Science.gov (United States)

    Tellis, V A; Kohlberg, W I; Bhat, D J; Driscoll, B; Veith, F J

    1979-01-01

    In a retrospective study of 66 PTFE arteriovenous fistulae and 71 BCH arteriovenous fistulae for dialysis access, PTFE had a higher patency rate than BCH at 12 months (62.4 versus 32.5%). PTFE was easier to work with and easier to handle in the face of infection. The lateral upper arm approach to placement of the PTFE graft is desirable in patients who have had multiple previous access procedures because this area is usually free from scarring, is distant from neurovascular structures, and provides a greater length of graft for needle punctures.

  12. Historical development of modern anesthesia.

    Science.gov (United States)

    Robinson, Daniel H; Toledo, Alexander H

    2012-06-01

    Of all milestones and achievements in medicine, conquering pain must be one of the very few that has potentially affected every human being in the world. It was in 1846 that one of mankind's greatest fears, the pain of surgery, was eliminated. This historical review article describes how the various elements of anesthesiology (gasses, laryngoscopes, endotracheal tubes, intravenous medications, masks, and delivery systems) were discovered and how some brilliant entrepreneurs and physicians of the past two centuries have delivered them to humanity. One name stands out amongst all others when the founder of modern anesthesia is discussed, William T.G. Morton (1819-1868). A young Boston Dentist, Dr. Morton had been in the search for a better agent than what had been used by many dentists: nitrous oxide. With Dr. Morton's tenacity driven by enthusiasm and discovery, he and renowned surgeon at Massachusetts General Hospital, John Collins Warren (1778-1856) made history on October 16, 1846 with the first successful surgical procedure performed with anesthesia. Dr. Morton had single-handedly proven to the world that ether is a gas that when inhaled in the proper dose, provided safe and effective anesthesia. One of the first accounts of an endotracheal tube being used for an airway comes from the pediatrician Joseph O'Dwyer (1841-1898). He used the metal "O'dwyer" tubes in diphtheria cases and passed them into the trachea blindly. Adding a cuff to the tube is credited to Arthur Guedel (1883-1956) and Ralph M. Waters (1883-1979) in 1932. This addition suddenly gave the practitioner the ability to provide positive pressure ventilation. The anesthesiologist Chevalier Jackson (1865-1958) promoted his handheld laryngoscope for the insertion of endotracheal tubes and its popularity quickly caught hold. Sir Robert Reynolds Macintosh's (1897-1989) breakthrough technique of direct laryngoscopy came after being appointed Nuffield professor of anesthetics at the University of Oxford

  13. Self-Expandable Stenting over a Stent Graft for the Exclusion of a Carotid Stump: Troubleshooting for Device Incompatibility

    International Nuclear Information System (INIS)

    Youn, Sung Won; Kim, Ho Kyun; Do, Jin Kook; Kim, Young Whan

    2011-01-01

    Carotid stump, the blind remnant of an occluded internal carotid artery, can be a potential source of microemboli, and warrants its exclusion from the vascular lumen to prevent the recurrence of a microembolism. In a 69-year-old male with a symptomatic carotid stump and acute angle between left common carotid artery and aortic arch, a 7-Fr. shuttle sheath was scarcely placed into the left carotid artery but the 7-mm-diameter stent-graft-loading balloon could not be inserted into the 7-Fr. shuttle sheath. With the mounting a stent graft over a 5-mm balloon, the balloon-expandable stent graft was unfolded. The self-expandable stent was placed over the stent graft, and an 8-mm balloon was subsequently expanded. Self-expanding stenting can be useful for troubleshooting in a case of device incompatibility coming from the different calibers of the external and common carotid arteries for the successful exclusion of a symptomatic carotid stump.

  14. Successful Treatment of Plantar Hyperkeratosis in the Form of Recurrent Corns With Split-Thickness Sole Skin Graft.

    Science.gov (United States)

    Wang, Chi-Yu; Chang, Chun-Kai; Chou, Chang-Yi; Wu, Chien-Ju; Chu, Tzi-Shiang; Chiao, Hao-Yu; Chen, Chun-Yu; Chen, Tim-Mo; Tzeng, Yuan-Sheng

    2018-02-01

    Plantar hyperkeratosis, such as corns and calluses, is common in older people and associated with pain, mobility impairment, and functional limitations. It usually develops on the palms, knees, or soles of feet, especially under the heels or balls. There are several treatment methods for plantar hyperkeratosis, such as salicylic acid plaster and scalpel debridement, and conservative modalities, such as using a shoe insert and properly fitting shoes. We present an effective method of reconstructing the wound after corn excision using a split-thickness sole skin graft (STSSG). We harvested the skin graft from the arch of the sole using the dermatome with a skin thickness of 14/1000th inches. Because the split-thickness skin graft, harvested from the sole arch near the distal sole, is much thicker than the split-thickness skin graft from the thigh, it is more resistant to weight and friction. The healed wound with STSSG coverage over the distal sole was intact, and the donor site over the sole arch had healed without complication during the outpatient follow-up, 3 months after surgery. The recovery time of STSSG for corn excision is shorter than that with traditional treatment. Therefore, STSSG can be a reliable alternative treatment for recurrent palmoplantar hyperkeratosis.

  15. Self-Expandable Stenting over a Stent Graft for the Exclusion of a Carotid Stump: Troubleshooting for Device Incompatibility

    Energy Technology Data Exchange (ETDEWEB)

    Youn, Sung Won; Kim, Ho Kyun [Dept. of Radiology, Catholic University of Daegu School of Medicine, Daegu (Korea, Republic of); Do, Jin Kook [Dept. of Neurology, Catholic University of Daegu School of Medicine, Daegu (Korea, Republic of); Kim, Young Whan [Dept. of Radiology, University College of Medicine, Daegu (Korea, Republic of)

    2011-12-15

    Carotid stump, the blind remnant of an occluded internal carotid artery, can be a potential source of microemboli, and warrants its exclusion from the vascular lumen to prevent the recurrence of a microembolism. In a 69-year-old male with a symptomatic carotid stump and acute angle between left common carotid artery and aortic arch, a 7-Fr. shuttle sheath was scarcely placed into the left carotid artery but the 7-mm-diameter stent-graft-loading balloon could not be inserted into the 7-Fr. shuttle sheath. With the mounting a stent graft over a 5-mm balloon, the balloon-expandable stent graft was unfolded. The self-expandable stent was placed over the stent graft, and an 8-mm balloon was subsequently expanded. Self-expanding stenting can be useful for troubleshooting in a case of device incompatibility coming from the different calibers of the external and common carotid arteries for the successful exclusion of a symptomatic carotid stump.

  16. Graft copolimerization of hydrophilic monomers onto irradiated polypropylene fibers

    International Nuclear Information System (INIS)

    Sundardi, F.

    1978-01-01

    A method of graft copolymerization of hydrophilic monomers, such as 1-vinyl-2-pyrrolidone, acrylonitrile, acrylic acid, and acrylamide, onto irradiated polypropylene fibers has been studied. γ ray as well as electron beam were employed for the irradiation processes. Graft-copolymerization kinetics and the properties of grafted fibers have been investigated. Moisture regain, dyes absorption, and melting point of the grafted fibers were found to increase with the increasing of the degree of grafting. Polypropylene for 1-vinyl-2-pyrrolidone grafted fibers showed excellent dye absorption for almost all kinds of dyes such as direct, basic, acid, reactive, disper, and naphthol dyes. However, for polypropylene acrylic acid grafted fibers, the colorfastness to washing was found to be unsatisfactory. The colorfastness to washing for polypropylene 1-vinyl-2-pyrrolidone grafted fibers was found to be fairly good for certain types of dyes such as vat and naphthol dyes. (author)

  17. Current Role of Imaging in Diagnosing Aortic Graft Infections

    NARCIS (Netherlands)

    Bruggink, Janneke L. M.; Slart, Riemer H. J. A.; Pol, Jillis A.; Reijnen, Michel M. P. J.; Zeebregts, Clark J.

    2011-01-01

    Vascular prosthetic graft infection is a rare but serious complication after aortic graft replacement, with high morbidity and mortality rates. Therefore, adequate diagnostics are needed to detect and treat these infections as early as possible. Several imaging modalities provide different

  18. Revascularisation of fresh compared with demineralised bone grafts in rats

    DEFF Research Database (Denmark)

    Solheim, E; Pinholt, E M; Talsnes, O

    2001-01-01

    Revascularisation of bone grafts is influenced by both the anatomical origin and the pre-implantation processing of the graft. We investigated the revascularisation by entrapment of 141Ce (cerium)-labelled microspheres in large, fresh and demineralised syngeneic grafts of predominantly cancellous...... (iliac bone) or cortical (tibial diaphysis) bone three weeks after heterotopic implantation in rats. The mean (SD) 141Ce deposition index (counts per minute (cpm) of mg recovered implant/cpm of mg host iliac bone) was higher in fresh iliac bone grafts, 0.98 (0.46) compared to that of demineralised iliac...... bone, 0.32 (0.20), p bone grafts, 0.51 (0.27), p = 0.007. We found no significant difference in the mean 141Ce deposition index between fresh tibial bone grafts and demineralised tibial bone grafts, 0.35 (0.42), p = 0.4, or between demineralised tibial grafts and demineralised...

  19. Ethical perception of modern biotechnology

    African Journals Online (AJOL)

    Jane

    2011-09-30

    Sep 30, 2011 ... 1Social Impact of Biotechnology Development in Malaysia Research ... purpose of this paper is to examine the ethical perception of modern ... and social benefits of modern biotechnology, consumer .... Company or organisation directly involved in the production of ...... Food safety battle: organic vs. biotech.

  20. Readings in modernity in Africa

    NARCIS (Netherlands)

    Geschiere, P.; Meyer, B.; Pels, P.

    2008-01-01

    This book provides students of Africa with a guide to the bewildering variety of scholarly work on the issue of modernity in Africa, and to offer some tools for dealing with its intellectual paradoxes. Part One contains both analytical and historical examples of the genealogies of modernity in the

  1. Modern logic and quantum mechanics

    International Nuclear Information System (INIS)

    Garden, R.W.

    1984-01-01

    The book applies the methods of modern logic and probabilities to ''interpreting'' quantum mechanics. The subject is described and discussed under the chapter headings: classical and quantum mechanics, modern logic, the propositional logic of mechanics, states and measurement in mechanics, the traditional analysis of probabilities, the probabilities of mechanics and the model logic of predictions. (U.K.)

  2. The Paradox of Modern Suffering

    DEFF Research Database (Denmark)

    Dræby, Anders

    The Paradox of Suffering in modern western Culture In non-western cultures and pre-modern western cultures suffering is considered the normal state of life. Corrispondingly the suffering of oneself and that of other people form a central focus to most religions, their practices and philosophies...

  3. Archives: Annals of Modern Education

    African Journals Online (AJOL)

    Items 1 - 8 of 8 ... Archives: Annals of Modern Education. Journal Home > Archives: Annals of Modern Education. Log in or Register to get access to full text downloads. Username, Password, Remember me, or Register · Journal Home · ABOUT THIS JOURNAL · Advanced Search · Current Issue · Archives. 1 - 8 of 8 Items. 2016 ...

  4. Modern biogeochemistry environmental risk assessment

    CERN Document Server

    Bashkin, Vladimir N

    2006-01-01

    Most books deal mainly with various technical aspects of ERA description and calculationsAims at generalizing the modern ideas of both biogeochemical and environmental risk assessment during recent yearsAims at supplementing the existing books by providing a modern understanding of mechanisms that are responsible for the ecological risk for human beings and ecosystem

  5. Mendel in the Modern Classroom

    Science.gov (United States)

    Smith, Mike U.; Gericke, Niklas M.

    2015-01-01

    Mendel is an icon in the history of genetics and part of our common culture and modern biology instruction. The aim of this paper is to summarize the place of Mendel in the modern biology classroom. In the present article we will identify key issues that make Mendel relevant in the classroom today. First, we recount some of the historical…

  6. Lycopene and flesh colour differences in grafted and non-grafted watermelon

    OpenAIRE

    Fekete D.; Stéger-Máté M.; Bőhm V.; Balázs G.; Kappel N.

    2015-01-01

    The experiment was carried out in three regions in Hungary (Jászszentandrás, Cece, Újkígyós) in 2013 to determine the fruit quality of grafted watermelon (Citrullus lanatus Thunb.). The “RX 467” seedless watermelon variety was grafted on two commercial rootstocks “FR STRONG” [Lagenaria siceraria (Mol.) Standl.] and “RS 841” (Cucurbita maxima Duchesne × Cucurbita moschata Duchesne). The lycopene and flesh colours are important quality characteristics even of the selfrooted and grafted watermel...

  7. Die Verfassung des Experiments Moderne

    Directory of Open Access Journals (Sweden)

    Manfred Aschke

    2005-01-01

    Full Text Available The question whether freedom of religion requires permitting the slaughter of animals in accordance with Islamic rites – a question which was the subject of a decision by the German Federal Constitutional Court in 2002 –is an example of the general problem how the law and the constitution of a modern, secular society can deal with the Sharia, a theonomous law which claims authority by divine revelation. The genetic links between western christianity and the development of the foundations of modern society in Europe do not provide evidence of the incompatibility of Islam and modernity. But they do emphasize that the tensions resulting from the immigration of 3 million muslims in Germany are a great challenge for the constitutional order. A modern constitution of the Western European and North-Atlantic type, such as the german constitution (Grundgesetz, does not allow the dissolution of the tensions between secular law and individual religious autonomy unilaterally in favour of the secular law. This kind of tension is by no means unknown in modern society. Functional differentiation and individualization are core characteristics of modern society. But in view of the challenge by Islam and other challenges, such as ecological problems, we can ask if the »experiment in modernity«, the project of the Enlightenment, is destined to fail because of the dissonance and the lack of understanding between the partial systems of the society. This question is the starting point to outline evolutionary processes of integration in modern society. In this context the constitution proves to be an important tool of integration. Controversies about the scope of validity claimed by the partial systems are matters of constitutional law. The modern constitution is a specific form in which modern society describes itself as a unity insuring »practical concordance« between colliding freedoms and claims of validity. In the conflict of modern ethical principles of

  8. Sulfonated hydrocarbon graft architectures for cation exchange membranes

    DEFF Research Database (Denmark)

    Nielsen, Mads Møller; Jankova Atanasova, Katja; Hvilsted, Søren

    2013-01-01

    A synthetic strategy to hydrocarbon graft architectures prepared from a commercial polysulfone and aimed as ion exchange membrane material is proposed. Polystyrene is grafted from a polysulfone macroinitiator by atom transfer radical polymerization, and subsequently sulfonated with acetyl sulfate...... to various degrees. Series of grafting densities and graft lengths are prepared, and membranes are solvent cast from DMSO. The membrane properties in aqueous environments are evaluated from their water swelling behavior, and their thermal properties and stability are investigated by thermogravimetric...

  9. Striatal grafts in a rat model of Huntington's disease

    DEFF Research Database (Denmark)

    Guzman, R; Meyer, M; Lövblad, K O

    1999-01-01

    Survival and integration into the host brain of grafted tissue are crucial factors in neurotransplantation approaches. The present study explored the feasibility of using a clinical MR scanner to study striatal graft development in a rat model of Huntington's disease. Rat fetal lateral ganglionic...... time-points graft location could not be further verified. Measures for graft size and ventricle size obtained from MR images highly correlated with measures obtained from histologically processed sections (R = 0.8, P fetal rat lateral ganglionic...

  10. History of free skin grafting. Knowledge of empiricism?

    OpenAIRE

    Klasen, Hendrik Jan

    1981-01-01

    In the course of more than a hundred years, skin grafting has become a standard procedure in surgery. The indications for the several types of grafting have become rather uniform.The technical aids at the operations only differ in details. Especially the vast experience gained in World War II provided the opportunity to develop the technique of skin grafting and so the evolution of present day plastics surgery. However, virtually every step in the field of indications, selection of grafts, te...

  11. Radiation grafting of dimethylaminopropylacrylamide and dimethylaminopropylmethacrylamide onto polyethylene

    Energy Technology Data Exchange (ETDEWEB)

    Burillo, Guillermina; Oseguera, M.A. [UNAM, Inst. de Ciencias Nucleares, Mexico City (Mexico); Vazquez, Carmen; Castillo, L.P. del [UNAM, Inst. de Investigaciones en Materiales, Mexico City (Mexico)

    1997-11-01

    Radiation-induced grafting of dimethylaminopropylacrylamide and dimethylamino-propylmethacrylamide onto polyethylene films, by direct grafting of the vinyl monomers to a polymer by mutual irradiation, has been investigated. The kinetics of the reaction were studied at different irradiation temperatures, monomer concentration and dose rates of gamma rays, and the appropriate reaction conditions for graft polymerization were determined. The thermal and mechanical behavior of the grafted films by means of DMA, TMA, DSC and TGA were also investigated. (author).

  12. Radiation-induced grafting from binary mixture of monomers onto cellulose acetate film and the characterization of the graft copolymer

    International Nuclear Information System (INIS)

    Bhattacharyya, S.N.; Maldas, D.

    1984-01-01

    Binary mixtures of styrene and acrylamide in methanol-water were grafted onto cellulose acetate films by taking recourse to preirradiation grafting technique. The extent of total grafting was determined from the measured weight increase. The percent acrylamide residue in the graft copolymer was calculated from the observed nitrogen content but the polystyrene residue in the grafted sample was determined by IR spectral studies. When the specific permeability of water vapour through the grafted films is measured, it is observed that the specific permeability increases with the increase of grafting of acrylamide in all humidities, but in case of styrene which is a nonpolar molecule the permeability is found to show a reversed order. In the case of mixed graft the permeability pattern pertains to that when both styrene and acrylamide have their effective roles to play. (author)

  13. Immobilization of urease on grafted starch by radiation method

    International Nuclear Information System (INIS)

    Nguyenanh Dung; Nguyendinh Huyen

    1995-01-01

    The acrylamide was grafted by radiation onto starch which is a kind of polymeric biomaterial. The urease was immobilized on the grafted starch. Some experiments to observe the quantitative relationships between the percent graft and the activity of immobilized enzyme were determined. The enzyme activity was maintained by more than seven batch enzyme reactions. (author)

  14. Anterior palatal island advancement flap for bone graft coverage ...

    African Journals Online (AJOL)

    ... Palatal Island Advancement Flap was effective in bone graft coverage in premaxillary edentulous area. Conclusion: It can be used as an aid for bone graft coverage of premaxillary edentulous ridge, where the need for mucosa is small in width but long in length. Keywords: Anterior maxilla, bone graft, dental implant, ...

  15. Bone structure changes in iliac crest grafts combined with implants

    NARCIS (Netherlands)

    Verhoeven, Jan Willem; Ruijter, Jan M.; Koole, Ronald; de Putter, Cornelis; Cune, Marco S.

    2010-01-01

    Remodeling of onlay grafts combined with implants to the mandible results in predictable changes in the graft's radiographic density. We studied the relationship between changes in radiographic density and trabecular structure during the first year after onlay grafting with simultaneous implant

  16. Quantifying Long-term Retention of Excised Fat Grafts

    DEFF Research Database (Denmark)

    Herly, Mikkel; Ørholt, Mathias; Glovinski, Peter V.

    2017-01-01

    Background: Predicting the degree of fat graft retention is essential whenplanning reconstruction or augmentation with free fat grafting. Most surgeonsobserve volume loss over time after fat grafting; however, the portion lost toresorption after surgery is still poorly defined, and the time to re...

  17. Complications in skin grafts when continuing antithrombotic therapy prior to cutaneous surgery requiring skin grafting

    DEFF Research Database (Denmark)

    Jarjis, Reem Dina; Jørgensen, Lone; Finnerup, Kenneth

    2015-01-01

    Abstract The risk of postoperative bleeding and wound healing complications in skin grafts among anticoagulated patients undergoing cutaneous surgery has not been firmly established. The objective was to examine the literature and assess the risk of postoperative bleeding or wound healing...... complications in skin grafts among anticoagulated patients, compared with patients who discontinue or patients who are not receiving antithrombotic therapy prior to cutaneous surgery requiring skin grafting. A systematic review examining the effect of antithrombotic therapy on cutaneous surgery was performed...... studies were of prospective and retrospective design. Most of the reviewed studies suggest that the use of antithrombotic therapy can increase the risk of bleeding complications in skin grafts. These complications are only wound threatening and not life threatening. Therefore, this is of concern mostly...

  18. BOOK REVIEW: Modern Supersymmetry

    Science.gov (United States)

    Kulish, Petr P.

    2006-12-01

    We have spent more than twenty years applying supersymmetry (SUSY) to elementary particle physics and attempting to find an experimental manifestation of this symmetry. Terning's monograph demonstrates the strong influence of SUSY on theoretical elaborations in the field of elementary particles. It gives both an overview of modern supersymmetry in elementary particle physics and calculation techniques. The author, trying to be closer to applications of SUSY in the real world of elementary particles, is also anticipating the importance of supersymmetry for rigorous study of nonperturbative phenomena in quantum field theory. In particular, he presents the `exact' SUSY β function using instanton methods, phenomena of anomalies and dualities. Supersymmetry algebra is introduced by adding two anticommuting spinor generators to Poincaré algebra and by presenting massive and massless supermultiplets of its representations. The author prefers to use mostly the component description of field contents of the theories in question rather than the superfield formalism. Such a style makes the account closer to physical chartacteristics. Relations required by SUSY among β functions of the gauge, Yukawa and quartic interactions are checked by direct calculations as well as to all orders in perturbation theory, thus demonstrating that SUSY survives quantization. A discussion is included of the hierarchy problem of different scales of weak and strong interactions and its possible solution by the minimal supersymmetric standard model. Different SUSY breaking mechanisms are presented corresponding to a realistic phenomenology. The monograph can also be considered as a guide to `duality' relations connecting different SUSY gauge theories, supergravities and superstrings. This is demonstrated referring to the particular properties and characteristics of these theories (field contents, scaling dimensions of appropriate operators etc). In particular, the last chapter deals with the Ad

  19. Dynamics of solvent-free grafted nanoparticles

    KAUST Repository

    Chremos, Alexandros

    2012-01-01

    The diffusivity and structural relaxation characteristics of oligomer-grafted nanoparticles have been investigated with simulations of a previously proposed coarse-grained model at atmospheric pressure. Solvent-free, polymer-grafted nanoparticles as well as grafted nanoparticles in a melt were compared to a reference system of bare (ungrafted) particles in a melt. Whereas longer chains lead to a larger hydrodynamic radius and lower relative diffusivity for grafted particles in a melt, bulk solvent-free nanoparticles with longer chains have higher relative diffusivities than their short chain counterparts. Solvent-free nanoparticles with short chains undergo a glass transition as indicated by a vanishing diffusivity, diverging structural relaxation time and the formation of body-centered-cubic-like order. Nanoparticles with longer chains exhibit a more gradual increase in the structural relaxation time with decreasing temperature and concomitantly increasing particle volume fraction. The diffusivity of the long chain nanoparticles exhibits a minimum at an intermediate temperature and volume fraction where the polymer brushes of neighboring particles overlap, but must stretch to fill the interparticle space. © 2012 American Institute of Physics.

  20. Mesh-graft urethroplasty: a case report

    OpenAIRE

    田中, 敏博; 滝川, 浩; 香川, 征; 長江, 浩朗

    1987-01-01

    We used a meshed free-foreskin transplant in a two-stage procedure for reconstruction of the extended stricture of urethra after direct vision urethrotomy. The results were excellent. Mesh-graft urethroplasty is a useful method for patients with extended strictures of the urethra or recurrent strictures after several operations.

  1. Fatal Saccharomyces Cerevisiae Aortic Graft Infection

    Science.gov (United States)

    Meyer, Michael (Technical Monitor); Smith, Davey; Metzgar, David; Wills, Christopher; Fierer, Joshua

    2002-01-01

    Saccharomyces cerevisiae is a yeast commonly used in baking and a frequent colonizer of human mucosal surfaces. It is considered relatively nonpathogenic in immunocompetent adults. We present a case of S. cerevisiae fungemia and aortic graft infection in an immunocompetent adult. This is the first reported case of S. cerevisiue fungemia where the identity of the pathogen was confirmed by rRNA sequencing.

  2. Grafting functional antioxidants on highly crosslinked polyethylene

    Science.gov (United States)

    Al-Malaika, S.; Riasat, S.; Lewucha, C.

    2016-05-01

    The problem of interference of antioxidants, such as hindered phenols, with peroxide-initiated crosslinking of polyethylene was addressed through the use of functional (reactive) graftable antioxidants (g-AO). Reactive derivatives of hindered phenol and hindered amine antioxidants were synthesised, characterised and used to investigate their grafting reactions in high density polyethylene; both non-crosslinked (PE) and highly peroxide-crosslinked (PEXa). Assessment of the extent of in-situ grafting of the antioxidants, their retention after exhaustive solvent extraction in PE and PEXa, and the stabilising performance of the grafted antioxidants (g-AO) in the polymer were examined and benchmarked against conventionally stabilised crosslinked & non-crosslinked polyethylene. It was shown that the functional antioxidants graft to a high extent in PEXa, and that the level of interference of the g-AOs with the polymer crosslinking process was minimal compared to that of conventional antioxidants which bear the same antioxidant function. The much higher level of retention of the g-AOs in PEXa after exhaustive solvent extraction, compared to that of the corresponding conventional antioxidants, accounts for their superior long-term thermal stabilising performance under severe extractive conditions.

  3. Cellular grafts in management of leucoderma

    Directory of Open Access Journals (Sweden)

    Mysore Venkataram

    2009-01-01

    Full Text Available Cellular grafting methods constitute important advances in the surgical management of leucoderma. Different methods such as noncultured epidermal suspensions, melanocyte cultures, and melanocyte-keratinocyte cultures have all been shown to be effective. This article reviews these methods.

  4. Effect of Grafting Method, Graft Cover and Foliar Spray of some Mineral Elements on Persian Walnut Graft-take and Winter Survival Rate

    Directory of Open Access Journals (Sweden)

    Reza Rezaee

    2017-09-01

    Full Text Available Introduction: Persian walnut (Juglans regia L. is an important nut crop in Iran and many parts of the world. One of the major challenges of growing walnut is planting of non-grafted walnut trees in orchards, which leads to the reduction of yield, quality and productivity of walnut orchards. Compared to the other fruit trees, walnut grafting is difficult and even newly grafted walnut seedlings are vulnerable to fall or winter frost chilling, so that most of the seedlings are lost after subjecting to the cold winter. There are a few studies reporting successful grafting in outdoor conditions, however, final grafting take after winter has been usually ignored. Hence, increased walnut grafting success and improved tree growth after grafting through foliar nutrient application may lead to increased tolerance of chilling. Therefore, main goals of this research were to investigate the effect of some graft covers and role of foliar spray of calcium, boron and zinc on the reduction of frost damage in newly grafted seedlings under outdoor conditions. Materials and methods: This research was conducted at agricultural research station, Khoy city, west Azerbaijan province, during 2012-2014. In the first experiment, three methods of grafting including cleft, bark and V-shaped, and two kinds of graft covers including moist sawdust and superabsorbent plus cotton wool were investigated in terms of grafting success and quality of seedlings. In the second experiment, effect of the three above-mentioned grafting methods and two levels of foliar spray including sequential spray of Ca (4 ppm, B and Zn (2% (3 times during growth season and control (no spray were studied in terms of frost damage. The experiments conducted in factorial based on randomized complete block design with 10 trees in each plot. Data were collected 45 days after grafting take, final grafting take after one winter, subsequent scion growth length and diameter and concentration of Ca, B and Zn in

  5. Automatic needle insertion diminishes pain during growth hormone injection

    DEFF Research Database (Denmark)

    Main, K M; Jørgensen, J T; Hertel, N T

    1995-01-01

    prototype pens for GH administration, providing either manual or automatic sc needle insertion, using a combined visual analogue/facial scale and a five-item scale in 18 children. With the automatic pen there was a significantly lower maximum pain score compared with the manual pen (median 28.5 versus 52.......0 mm) as well as a lower mean pain score (mean 13.7 versus 23.5 mm). The five-item scale revealed that automatic needle insertion was significantly less painful than manual insertion and 13 patients chose to continue treatment with the automatic pen. In conclusion, pain during GH injection can...

  6. Lithium insertion mechanism in SnS2

    International Nuclear Information System (INIS)

    Lefebvre-Devos, I.; Olivier-Fourcade, J.; Jumas, J.C.; Lavela, P.

    2000-01-01

    We study lithium insertion in SnS 2 by means of 119 Sn Moessbauer spectroscopy, x-ray absorption spectroscopy at Sn L I,III , and S K edges, and theoretical electronic structures (calculated in the density-functional theory framework). An insertion mechanism is derived according to the Li amount. It shows the influence of the SnS 2 -layered structure on the Sn reduction, particularly the possibility of an intermediate oxidation state between Sn IV and Sn II , which is not observed during Li insertion in three-dimensional sulfides

  7. Interpreted Modernity. Weber and Taylor on Values and Modernity

    OpenAIRE

    Reckling, Falk

    2001-01-01

    The writings of Weber and Taylor have some strong affinities. Both start from the anthropological idea that man evaluates his position in the world and constitutes the social world by values. Their analyses of values aim at an understanding of those intersubjective meanings that have constituted western modernity. But, at the same time, their anthropological starting point leads to different interpretations of modernity. Historically, both argue that rationalization (as instrumental rationali...

  8. Rib Bone Graft Adjusted to Fit the Facial Asymmetry: A Frame Structure Graft.

    Science.gov (United States)

    Lee, Yoon Ho; Choi, Jong Hwan; Hwang, Kun; Choi, Jun Ho

    2015-10-01

    The authors introduce the concept of a "frame structure graft" in which a harvested rib bone was adjusted to fit facial asymmetry. On the costochondral junction of the sixth or seventh rib, a 5 cm incision was made. Through a subperiosteal dissection, the rib bone was harvested. Using a reciprocating saw, the harvested rib was scored on its anterior surface as well as its posterior surface with a partial depth at different intervals. The harvested rib bone was placed on the skin surface of the unaffected side of the face and a curvature was created exactly matching that of the unaffected side by bending the bone using a greenstick fracture. Thereafter, the graft was adjusted to conceal the asymmetry of the deficient side. The adjusted "frame structure" was transferred to the defect through the incisions on the affected side, and the "frame structure" graft was placed on the mandible or zygoma. The graft fixation was done externally with at least 2 Kirschner wires (K-wires). From January 2005 to August 2013, a total of 30 patients (13 men, 17 women, mean age 25.6 years) received a frame structure graft. All 30 patients achieved good healing at the operation site without complications. Donor-site morbidity as pneumothorax from the rib bone harvest was not found. Merits of this frame structure graft, the authors think, are that this method could allow a similar curvature to the normal side. In addition, the procedure itself is easy.

  9. Soft tissue grafting to improve implant esthetics

    Directory of Open Access Journals (Sweden)

    Moawia M Kassab

    2010-09-01

    Full Text Available Moawia M KassabDivision of Periodontics, Marquette University, School of Dentistry, Milwaukee, WI, USAAbstract: Dental implants are becoming the treatment of choice to replace missing teeth, especially if the adjacent teeth are free of restorations. When minimal bone width is present, implant placement becomes a challenge and often resulting in recession and dehiscence around the implant that leads to subsequent gingival recession. To correct such defect, the author turned to soft tissue autografting and allografting to correct a buccal dehiscence around tooth #24 after a malpositioned implant placed by a different surgeon. A 25-year-old woman presented with the chief complaint of gingival recession and exposure of implant threads around tooth #24. The patient received three soft tissue grafting procedures to augment the gingival tissue. The first surgery included a connective tissue graft to increase the width of the keratinized gingival tissue. The second surgery included the use of autografting (connective tissue graft to coronally position the soft tissue and achieve implant coverage. The third and final surgery included the use of allografting material Alloderm to increase and mask the implant from showing through the gingiva. Healing period was uneventful for the patient. After three surgical procedures, it appears that soft tissue grafting has increased the width and height of the gingiva surrounding the implant. The accomplished thickness of gingival tissue appeared to mask the showing of implant threads through the gingival tissue and allowed for achieving the desired esthetic that the patient desired. The aim of the study is to present a clinical case with soft tissue grafting procedures.Keywords: case report, connective tissue, dental implants, allograft, coronally positioned flap

  10. Postmodernism in Belgrade architecture: Between cultural modernity and societal modernization

    Directory of Open Access Journals (Sweden)

    Blagojević Ljiljana

    2011-01-01

    Full Text Available The paper explores the introduction and articulation of ideas and aesthetic practice of postmodernism in architecture of late socialism in Yugoslavia, with the focus on Belgrade architecture scene. Theoretical and methodological point of departure of this analysis is Jürgen Habermas's thesis of modernity as an incomplete, i.e., unfinished project, from his influential essay “Die Moderne: Ein unvollendetes Projekt” (1980. The thematic framework of the paper is shifted towards issues raised by Habermas which concern relations of cultural modernity and societal modernization, or rather towards consideration of architectural postmodernity in relation to the split between culture and society. The paper investigates architectural discourse which was profiled in Belgrade in 1980s, in a historical context of cultural modernity simultaneous with Habermas's text, but in different conditions of societal modernization of Yugoslav late socialism. In that, the principle methodological question concerns the interpretation of postmodern architecture as part of the new cultural production within the social restructuration of late and/or end of socialism as a system, that being analogous to Fredric Jameson's thesis of “Postmodernism, Or, The Cultural Logic of Late Capitalism” (1984.

  11. A data science approach for quantifying spatio-temporal effects to graft failures in organ transplantation.

    Science.gov (United States)

    Pinheiro, Diego; Hamad, Farag; Cadeiras, Martin; Menezes, Ronaldo; Nezamoddini-Kachouie, Nezamoddin

    2016-08-01

    The transplantation of solid organs is one of the most important accomplishments of modern medicine. Yet, organ shortage is a major public health issue; 8,000 people died while waiting for an organ in 2014. Meanwhile, the allocation system currently implemented can lead to organs being discarded and the medical community still investigates factors that affects early graft failure such as distance and ischemic time. In this paper, we investigate early graft failure under a spatio-temporal perspective using a data science unified approach for all six organs that is based on complementary cumulative analysis of both distance and ischemic time. Interestingly, although distance seems to highly affect some organs (e.g. liver), it appears to have no effect on others (e.g. kidney). Similarly, the results on ischemic time confirm it affects early graft failure with higher influence for some organs such as (e.g. heart) and lower influence for others such as (e.g. kidney). This poses the question whether the allocation policies should be individually designed for each organ in order to account for their particularities as shown in this work.

  12. Corneal graft reversal: Histopathologic report of two cases

    OpenAIRE

    Qahtani, Abdullah A.; Alkatan, Hind M.

    2014-01-01

    Graft reversal is a rare cause for failed PKP. In this case report we are presenting 2 graft failure cases in which the corneal grafts were reversed unintentionally. The onset of signs of graft failure, however was variable. We have included their clinical course and the histopathologic findings of the removed corneal grafts. A total of 6 cases including ours have been reported so far. The aim of this report is to attract the attention of corneal surgeons to an additional rare cause for faile...

  13. Reconstruction of partially amputated external ear with costal cartilage graft: case report.

    Science.gov (United States)

    Brunelli, A; Bottini, D J; Cervelli, V; Cervelli, G; Grimaldi, M

    2004-06-01

    Many causes are responsible for secondary anomalies of the outer ear, such as: car accidents, sport- or work-related accidents, assaults, bites from animals or humans, benign or malignant tumours, burns and the effects of surgical interventions of the ear (plastic surgery on the ear or attempts at correction of primary malformations of the ear). The anatomical complexity of the ear makes its reconstruction particularly complicated with post-operative results that are often disappointing. The Authors describe their experience in the reconstruction of a partially amputated outer ear following a dog bite. The therapeutic protocol required various surgical stages. Initially, a cutaneous expander was applied at the level of the mastoid in order to ensure a sufficient quantity of local skin. The second stage was to remove cartilage from the ribs, followed by construction of a cartilaginous model of the ear and its insertion into the subcutaneous mastoid region after removal of the cutaneous expander and any residual ear cartilage. The last stage was to separate the neo-formed outer ear from the mastoid skin with the insertion of a cartilage graft to the posterior region of the reconstructed ear. This graft was covered by the occipital fascia rotated at 180 degrees and by a skin graft removed from the pubis. The postoperative result was satisfactory with recuperation of a good aesthetic appearance of the ear. Aim of the present report is to describe the surgical technique employed in the reconstruction of secondary anomalies of the ear and to highlight errors committed during this procedure. These considerations have allowed us to stress some fundamental elements in the reconstruction of the ear. In particular, the watershed was the awareness that we had to create a cartilaginous model that respected, as far as possible, the anatomy of the outer ear with all its ridges, trenches and cavities. This as well as ensuring a sufficient quantity of local skin in order to cover

  14. A methodology for spacecraft technology insertion analysis balancing benefit, cost, and risk

    Science.gov (United States)

    Bearden, David Allen

    Emerging technologies are changing the way space missions are developed and implemented. Technology development programs are proceeding with the goal of enhancing spacecraft performance and reducing mass and cost. However, it is often the case that technology insertion assessment activities, in the interest of maximizing performance and/or mass reduction, do not consider synergistic system-level effects. Furthermore, even though technical risks are often identified as a large cost and schedule driver, many design processes ignore effects of cost and schedule uncertainty. This research is based on the hypothesis that technology selection is a problem of balancing interrelated (and potentially competing) objectives. Current spacecraft technology selection approaches are summarized, and a Methodology for Evaluating and Ranking Insertion of Technology (MERIT) that expands on these practices to attack otherwise unsolved problems is demonstrated. MERIT combines the modern techniques of technology maturity measures, parametric models, genetic algorithms, and risk assessment (cost and schedule) in a unique manner to resolve very difficult issues including: user-generated uncertainty, relationships between cost/schedule and complexity, and technology "portfolio" management. While the methodology is sufficiently generic that it may in theory be applied to a number of technology insertion problems, this research focuses on application to the specific case of small (<500 kg) satellite design. Small satellite missions are of particular interest because they are often developed under rigid programmatic (cost and schedule) constraints and are motivated to introduce advanced technologies into the design. MERIT is demonstrated for programs procured under varying conditions and constraints such as stringent performance goals, not-to-exceed costs, or hard schedule requirements. MERIT'S contributions to the engineering community are its: unique coupling of the aspects of performance

  15. Basics of modern mathematical statistics

    CERN Document Server

    Spokoiny, Vladimir

    2015-01-01

    This textbook provides a unified and self-contained presentation of the main approaches to and ideas of mathematical statistics. It collects the basic mathematical ideas and tools needed as a basis for more serious studies or even independent research in statistics. The majority of existing textbooks in mathematical statistics follow the classical asymptotic framework. Yet, as modern statistics has changed rapidly in recent years, new methods and approaches have appeared. The emphasis is on finite sample behavior, large parameter dimensions, and model misspecifications. The present book provides a fully self-contained introduction to the world of modern mathematical statistics, collecting the basic knowledge, concepts and findings needed for doing further research in the modern theoretical and applied statistics. This textbook is primarily intended for graduate and postdoc students and young researchers who are interested in modern statistical methods.

  16. TRADITION, MODERNISM, AND APARTHEID1

    African Journals Online (AJOL)

    in future with important examples of a politics that moves beyond the spatialising ... (despite the universally acclaimed nature of the present liberal-democratic constitution). ... Once mapped on such a grid, according to modernism, being can be.

  17. Measuring Older Adults’ Individual Modernity

    Directory of Open Access Journals (Sweden)

    Xue Bai

    2016-02-01

    Full Text Available Research shows that maintaining high individual modernity level can enable the shaping of positive self-image and boost life satisfaction for older people along with better adaptation to the process of societal modernization. This study examined the factorial structure and evaluated the psychometric properties of the adapted Multidimensional Scale of Chinese Individual Modernity (MS-CIM in a sample of 445 elders (the finalized version is named “MS-CIME” and added a self-constructed nine-item behavioral modernity domain. Principal component analysis suggested a conceptually meaningful seven-factor model, which was further supported by the results of the confirmatory factor analysis (CFA. The final 25-item MS-CIME indicated an acceptable level of reliability. The convergent validity was demonstrated by its associations with socio-economic status, participation in daily activities, self-image, and life satisfaction in expected directions.

  18. Effect of surface texture of grafted films on antithrombogenicity

    International Nuclear Information System (INIS)

    Otsuhata, K.; Razzak, M.T.; Castanares, R.L.; Tabata, Y.; Ohashi, F.; Takkeuchi, A.

    1985-01-01

    The relation between grafting conditions and antithrombogenicity has been examined from the purpose of clearing the necessity of controlling grafting conditions to enhance blood compatibility. The grafting systems employed here were N,N-dimethylacrylamide (DMAA) - poly(tetrafluoroethylene) (PTFE) and DMAA - poly(ethylene-co-tetrafluoroethylene) (AFLON) and grafting parameters were dose rate, monomer concentration and total dose (irradiation time). Grafting DMAA on to the substrates was carried out by using simultaneous irradiation method of gamma rays from a 60 Co source. After evaluation of blood compatibility of the grafted films by using in vitro tests, it has been clear that control of grafting conditions is important. Especially, in both grafting systems, dose rate control has found to be very important for blood compatibility. When higher dose rate of 1.0 x 10 5 to 3.0 x 10 5 rad/hr was used for grafting DMAA on to PTFE or AFLON, blood compatibility of the substrates was not enhanced, whereas it was improved when the grafting was carried out at lower dose rate of 0.97 x 10 4 rad/hr. The correlation between dose rate and antithrombogenicity has been interpreted in terms of surface-roughness of the grafted films. By scanning electron microscope (SEM) - observation, it has been observed that higher dose rate makes the surface rough, whereas lower dose rate makes it smooth. (author)

  19. Evaluation of coronary artery bypass grafts with magnetic resonance imaging

    International Nuclear Information System (INIS)

    Okamura, Yoshitaka; Yamada, Yasuyuki; Mochizuki, Yoshihiko; Iida, Hiroshi; Mori, Hideaki; Sugita, You-ichi; Shimada, Kou-ichirou

    1997-01-01

    Currently, the efficacy of magnetic resonance imaging (MRI) for evaluating coronary artery disease has been reported. In this study, we have evaluated the usefulness and the problems of MRI for evaluating the patency of coronary artery bypass grafts. Thirty-five patients who received coronary artery bypass grafting (CABG) were evaluated by using MRI for determining the graft patency compared with conventional coronary angiography. There were 30 men and 5 women. The mean age was 61.2 years (range 45 to 75). The 35 patients had a total of 92 grafts (28 internal thoracic artery, 7 gastroepiploic artery and 57 saphenous vein grafts). Magnetic resonance coronary angiogram (MRCA) was performed with SIGNA HORIZON 1.5 T (GE Inc.) by using 2D-FASTCARD sequence. All patients underwent imaging in the transverse and coronal planes, most had imaging in the sagittal plane, and a few had in the oblique plane. By using MRCA, 82 of 90 grafts were diagnosed correctly as patent, and 1 of 2 grafts were diagnosed correctly as occluded. Thirty-four of 40 LAD grafts (85%), 20 of 22 RCA grafts (91%) and 29 of 30 Cx grafts (97%) were correctly evaluated. The efficacy of MRCA for evaluating the patency of coronary artery bypass grafts was recognized. But the sternal wire (stainless steel) and hemoclip interfere with the interpretation and reduce the sensitivity. Higher sensitivity may be obtained by changing the material of the sternal wires and hemoclips at coronary surgery. (author)

  20. Radiation-induced grafting of acrylic acid onto polyethylene filaments

    International Nuclear Information System (INIS)

    Kaji, K.; Sakurada, I.; Okada, T.

    1981-01-01

    Radiation-induced grafting of acrylic acid onto high density polyethylene (PE) filaments was carried out in order to raise softening temperature and impart flame retardance and hydrophilic properties. Mutual γ-irradiation method was employed for the grafting in a mixture of acrylic acid (AA), ethylene dichloride and water containing a small amount of ferrous ammonium sulfate. The rate of grafting was very low at room temperature. On the other hand, large percent grafts were obtained when the grafting was performed at an elevated temperature. Activation energy for the initial rate of grafting was found to be 17 kcal/mol between 20 and 60 0 C and 10 kcal/ mol between 60 and 80 0 C. Original PE filament begins to shrink at 70 0 C, shows maximum shrinkage of 50% at 130 0 C and then breaks off at 136 0 C. When a 34% AA graft is converted to metallic salt the graft filament retains its filament form even above 300 0 C and gives maximum shrinkage of 15%. Burning tests by a wire-netting basket method indicate that graft filaments and their metallic salts do not form melting drops upon burning and are self-extinguishing. Original PE filament shows no moisture absorption; however, that of AA-grafted PE increases with increasing graft percent. (author)