WorldWideScience

Sample records for graft aneurysm ct

  1. Assessment of value of spiral CT in preoperative evaluation of endovascular graft exclusion for abdominal aortic aneurysm

    International Nuclear Information System (INIS)

    Jing Zaiping; Zhao Jun; Zhu Wenjiang; Xiao Yi

    1998-01-01

    Purpose: The assess the value of spiral CT (SCT) in preoperative evaluation of endovascular graft exclusion (EVGE) for abdominal aortic aneurysm (AAA). Methods: 41 case with AAA received SCT scanning. Two and three dimensional images were reconstructed, utilizing the shaded surface display (SSD), maximum-intensity Projection (MIP) and multiplanar reformation (MPR). Information were obtained regarding the size and features of AAA, length and diameters of aneurysm's neck, status of the branches of aorta, etc. Results: Nine patients had spinal CT study prior EVGE procedure and the grafts selected according to the parameters obtained by SCT matched perfectly to the needs of deployment. Conclusion: CTA provides high quality images. It is a high-speed and non-invasive method which can provide three-dimensional images of AAA and its main branches and all the parameters needed in EVGE

  2. Postoperative CT findings of aortic aneurysm and dissection

    International Nuclear Information System (INIS)

    Seong, Su Ok; Lee, Ghi Jai; Kim, Mi Young; Moon, Hi Eun; Shim, Jae Chan; Lee, Hong Sup; Kim, Ho Kyun; Han, Chang Yul

    1995-01-01

    To assess the postoperative CT findings of aortic aneurysms or dissections treared by resection-and graft replacement or continuous-suture graft-inclusion technique. We reviewed postoperative follow-up CT findings of 14 patients, 19 cases. There were 8 patients (10 cases) of aortic aneurysm and 6 patients (9 cases) of aortic dissection which involved the thoracic aorta in 9 patients (13 cases) and abdominal aorta in 5 patients (6 cases). The interval of follow-up after operation was from 9 days to 2 year 9 months. On CT scans, we analyzed the appearance of graft materials, differences of CT findings between two surgical techniques, and normal or abnormal postoperative CT findings. Most of grafts appeared as hyperdense ring on precontrast scan, and all of them were not separated from aortic lumen on postcontrast scan. On CT findings of patients who were operated by continuous-suture graft-inclusion technique, perigraft thrombus was concentrically located with sharp demarcation by native aortic wall and its density was homogeneous, but in cases of those operated by resection-and graft replacement, perigraft hematoma was eccentrically located with indistinct margin and its density was heterogeneous and native aortic wall could not be delineated. In patients without complication, perigraft thrombus or hematoma (15 cases), perigraft calcification (11 cases), residual intimal flap (6 cases), graft deformity (4 cases), perigraft air (2 cases) and reconstructed vessels (1 cases) were noted. And in one patient with complication, perigraft flow was noted with more increased perigraft hematoma. Precise knowledge of the differences of CT findings between two surgical techniques and normal postoperative CT findings is crucial to evaluated the postoperative CT findings in aortic aneurysm and dissection

  3. Endo-luminal grafting for treatment of abdominal aortic aneurysms

    International Nuclear Information System (INIS)

    Fu Weiguo; Wang Yuqi; Chen Fuzhen; Ye Jianrong; Wang Jianhua; Yan Zhiping; Cheng Jiemin

    2000-01-01

    Objective: To evaluate the preliminary clinical results of endovascular procedures for abdominal aortic aneurysms (AAA) in a prospective study. Methods: Six patients (average age 70 years, range 56 to 78) with infrarenal AAA were enrolled in Shanghai Zhongshan hospital from February 1998 to February 1999. Computed tomography and angiography were done in every patient for measurement of the length, diameter, and angulation of the proximal and distal AAA necks, aneurysm sac, and common and external iliac arteries. The average diameter of the aneurysm was 6.3 cm (range 4.6 cm to 8.0 cm). The mean proximal neck diameter was 2.0 cm (range 1.8 cm to 2.2 cm) and proximal neck length was 3.0 cm (range 2.5 cm to 3.5 cm). All patients were treated with the endo-luminal grafting for exclusion of AAA. Results: Two tubular and 4 bifurcated endo-grafts were used. All endo-graft procedures were completed successfully. One patient died of renal failure 72 hours after the procedure because of the prolonged operative time and excessive contrast medium. Aortography after the procedure showed the AAA were excluded by endo-graft and no endo-leak in the proximal or distal connections was detected. The patients could take meal and were ambulatory on the first and second postoperative day, respectively. Clinical success (aneurysm exclusion with no death or endo-leak) at 30 days was 83.3%. In the 24 months follow-up in 5 cases, no migration, endo-leak, and increasing aneurysm size were detected with spiral CT or color Duplex ultrasound. Conclusion: Based on initial results and a short term mean follow-up period of 24 months, the endovascular treatment of AAA with stent-graft system is feasible and safe. Further study will be required to observe the long term result in the exclusion of AAA

  4. Endovascular Tubular Stent-Graft Placement for Isolated Iliac Artery Aneurysms

    International Nuclear Information System (INIS)

    Okada, Takuya; Yamaguchi, Masato; Kitagawa, Atsushi; Kawasaki, Ryota; Nomura, Yoshikatsu; Okita, Yutaka; Sugimura, Kazuro; Sugimoto, Koji

    2012-01-01

    Purpose: To evaluate the safety, efficacy, and mid-term outcomes of endovascular tubular stent-graft placement for repair of isolated iliac artery aneurysms (IAAs). Materials and Methods: Between January 2002 and March 2010, 20 patients (7 women and 13 men; mean age 74 years) underwent endovascular repair of 22 isolated IAAs. Two patients underwent endovascular repair for bilateral aneurysms. Ten para-anastomotic aneurysms (45%) developed after open abdominal aortic aneurysm (AAA) repair with an aorto-iliac graft, and 12 were true aneurysms (55%). Eleven straight and 11 tapered stent-grafts were placed. Contrast-enhanced computed tomography (CT) was performed to detect complications and evaluate aneurysmal shrinkage at week 1, 3, 6, and 12 months and once every year thereafter. Non–contrast-enhanced CT was performed in seven patients with chronic kidney disease. Results: All procedures were successful, without serious complications, during the mean (range) follow-up period of 746 days (47–2651). Type II endoleak not requiring treatment was noted in one patient. The mean (SD) diameters of the true and para-anastomotic aneurysms significantly (p < 0.05) decreased from 42.0 (9.3) to 36.9 (13.6) mm and from 40.1 (13.0) to 33.6 (15.8) mm, respectively; the mean (SD) shrinkage rates were 15.1% (20.2%) and 18.9% (22.4%), respectively. The primary patency rate was 100%, and no secondary interventions were required. Four patients (21%) developed transient buttock claudication, and one patient (5%) developed colorectal ischaemia, which was treated conservatively. Conclusion: Endovascular tubular stent-graft placement for the repair of isolated IAAs is safe and efficacious. Tapered stent-grafts of various sizes are required for accurate placement.

  5. Late graft explants in endovascular aneurysm repair.

    Science.gov (United States)

    Turney, Eric J; Steenberge, Sean P; Lyden, Sean P; Eagleton, Matthew J; Srivastava, Sunita D; Sarac, Timur P; Kelso, Rebecca L; Clair, Daniel G

    2014-04-01

    With more than a decade of use of endovascular aneurysm repair (EVAR), we expect to see a rise in the number of failing endografts. We review a single-center experience with EVAR explants to identify patterns of presentation and understand operative outcomes that may alter clinical management. A retrospective analysis of EVARs requiring late explants, >1 month after implant, was performed. Patient demographics, type of graft, duration of implant, reason for removal, operative technique, length of stay, complications, and in-hospital and late mortality were reviewed. During 1999 to 2012, 100 patients (91% men) required EVAR explant, of which 61 were placed at another institution. The average age was 75 years (range, 50-93 years). The median length of time since implantation was 41 months (range, 1-144 months). Explanted grafts included 25 AneuRx (Medtronic, Minneapolis, Minn), 25 Excluder (W. L. Gore & Associates, Flagstaff, Ariz), 17 Zenith (Cook Medical, Bloomington, Ind), 15 Talent (Medtronic), 10 Ancure (Guidant, Indianapolis, Ind), 4 Powerlink (Endologix, Irvine, Calif), 1 Endurant (Medtronic), 1 Quantum LP (Cordis, Miami Lakes, Fla), 1 Aorta Uni Iliac Rupture Graft (Cook Medical, Bloomington, Ind), and 1 homemade tube graft. Overall 30-day mortality was 17%, with an elective case mortality of 9.9%, nonelective case mortality of 37%, and 56% mortality for ruptures. Endoleak was the most common indication for explant, with one or more endoleaks present in 82% (type I, 40%; II, 30%; III, 22%; endotension, 6%; multiple, 16%). Other reasons for explant included infection (13%), acute thrombosis (4%), and claudication (1%). In the first 12 months, 23 patients required explants, with type I endoleak (48%) and infection (35%) the most frequent indication. Conversely, 22 patients required explants after 5 years, with type I (36%) and type III (32%) endoleak responsible for most indications. The rate of EVAR late explants has increased during the past decade at our

  6. Percutaneous endovascular stent-graft treatment of aortic aneurysms and dissections: new techniques and initial experience

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Do Yun; Choi, Dong Hoon; Kang, Sung Gwon; Lee, Kwang Hoon; Won, Jong Yun [Yonsei University College of Medicine, Seoul (Korea, Republic of); Kang, Sung Gwon [Chosun University College of Medicine, Gwangju (Korea, Republic of); Won, Je Whan [Aju University College of Medicine, Suwon (Korea, Republic of); Song, Ho Young [Ulsan University College of Medicine, Seoul (Korea, Republic of)

    2003-01-01

    To evaluate the feasibility, safety and effectiveness of a newly designed percutaneously implanted separate stent-graft (SSG) for the treatment of aortic aneurysms and dissections. Using a percutaneous technique, SSG placement (in the descending thoracic aorta in 26 cases and infrarenal abdominal aorta in 24) was attempted in 50 patients with aortic aneurysms (n=27) or dissection (n=23). All SSGs were individually constructed using self-expandable nitinol stents and a Dacron graft, and were introduced through a 12 F sheath and expanded to a diameter of 20-34 mm. In all cases, vascular access was through the femoral artery. The clinical status of each patient was monitored, and postoperative CT was performed within one week of the procedure and at 3-6 month intervals afterwards. Endovascular stent-graft deployment was technically successful in 49 of 50 patients (98%). The one failure was due to torsion of the unsupported graft during deployment. Successful exclusion of aneurysms and the primary entry tears of dissections was achieved in all but three patients with aortic dissection. All patients in whom technical success was achieved showed complete thrombosis of the thoracic false lumen or aneurysmal sac, and the overall technique success rate was 92%. In addition, sixteen patients demonstrated complete resolution of the dissected thoracic false lumen (n=9) or aneurysmal sac (n=7). Immediate post-operative complications occurred at the femoral puncture site in one patient with an arteriovenous fistula, and in two, a new saccular aneurysm developed at the distal margin of the stent. No patients died, and there was no instance of paraplegia, stroke, side-branch occlusion or infection during the subsequent mean follow-up period of 9.4 (range, 2 to 26) months. In patients with aortic aneurysm and dissection, treatment with a separate percutaneously inserted stent-graft is technically feasible, safe, and effective.

  7. Fluid-structure interaction of a patient-specific abdominal aortic aneurysm treated with an endovascular stent-graft.

    LENUS (Irish Health Repository)

    Molony, David S

    2009-01-01

    BACKGROUND: Abdominal aortic aneurysms (AAA) are local dilatations of the infrarenal aorta. If left untreated they may rupture and lead to death. One form of treatment is the minimally invasive insertion of a stent-graft into the aneurysm. Despite this effective treatment aneurysms may occasionally continue to expand and this may eventually result in post-operative rupture of the aneurysm. Fluid-structure interaction (FSI) is a particularly useful tool for investigating aneurysm biomechanics as both the wall stresses and fluid forces can be examined. METHODS: Pre-op, Post-op and Follow-up models were reconstructed from CT scans of a single patient and FSI simulations were performed on each model. The FSI approach involved coupling Abaqus and Fluent via a third-party software - MpCCI. Aneurysm wall stress and compliance were investigated as well as the drag force acting on the stent-graft. RESULTS: Aneurysm wall stress was reduced from 0.38 MPa before surgery to a value of 0.03 MPa after insertion of the stent-graft. Higher stresses were seen in the aneurysm neck and iliac legs post-operatively. The compliance of the aneurysm was also reduced post-operatively. The peak Post-op axial drag force was found to be 4.85 N. This increased to 6.37 N in the Follow-up model. CONCLUSION: In a patient-specific case peak aneurysm wall stress was reduced by 92%. Such a reduction in aneurysm wall stress may lead to shrinkage of the aneurysm over time. Hence, post-operative stress patterns may help in determining the likelihood of aneurysm shrinkage post EVAR. Post-operative remodelling of the aneurysm may lead to increased drag forces.

  8. CT diagnosis of ruptured abdominal aortic aneurysm

    International Nuclear Information System (INIS)

    Sacknoff, R.; Novelline, R.A.; Wittenberg, J.; Waltman, A.C.; De Luca, S.A.; Rhea, J.T.; Lawrason, J.N.

    1986-01-01

    Ruptured abdominal aortic aneurysm (AAA) is a life-threatening condition requiring immediate diagnosis and surgery. In a series of 23 consecutive patients scanned by CT for suspected ruptured AAA, CT proved 100% accurate. In seven patients with surgically or pathologically proved ruptured AAA, CT demonstrated a similar distribution of hemorrhage into the perirenal space and to a lesser degree into the anterior and posterior pararenal spaces. The 16 true-negative examinations included ten in patients with unruptured AAA and six in patients with other diseases. The authors conclude that patients in stable condition with suspected ruptured AAA should be examined by CT

  9. Dynamic CT in dissecting aortic aneurysm

    International Nuclear Information System (INIS)

    Fujita, Nobuyuki; Matsuoka, Yosuke; Mizuo, Hideyo; Shirato, Hiroki; Irie, Goro

    1985-01-01

    especially about the branching of major vessels Eight cases of aortic dissection were analysed to evaluate detectability of the branching of major vessels from a ture or false lumen, by dynamic CT. Although recognition of the branching is easy when the direct continuity to a dissected lumen is demonstrated, but without visualization of direct continuity or with no information about dissected lumens, it is sometimes difficult or leads us to misdiagnosis. The diagnostic accuracy is 100% when direct continuity to a dissected lumen is demonstrated, or dynamic CT revealed branching pattern distinctly. Dynamic CT is useful for a diagnosis of dissecting aneurysm and branching pattern of major vessels. (author)

  10. Abdominal aortic aneurysm neck remodeling after Anaconda stent graft implantation.

    Science.gov (United States)

    Vukovic, Elisabeth; Czerny, Martin; Beyersdorf, Friedhelm; Wolkewitz, Martin; Berezowski, Mikolaj; Siepe, Matthias; Blanke, Philipp; Rylski, Bartosz

    2018-05-24

    The aim of this study was to define how the proximal landing zone changes geometrically after endovascular abdominal aortic aneurysm repair (EVAR) with the Anaconda (Vascutek, Inchinnan, United Kingdom) stent graft. Among 230 patients who underwent Anaconda stent graft implantation between 2005 and 2014, we included 126 with adequate computed tomography (CT) image quality and follow-up. CT analysis entailed the geometric changes in the main body, proximal rings, and proximal landing zone. The median CT follow-up was 2.0 years (345.8 patients-years). The proximal portion of the main body ring system flattened within the first year after EVAR, resulting in an up to 30° increase in the upper ring's angle in 40% patients and up to 40° increase in 24% patients. One year after EVAR, the upper ring angle increase slowed down. Aortic diameter measured at the level of the upper and lower ring expanded by 2 to 4 mm within 1 year, but remained unchanged afterward. The main body migrated continuously down toward the aortic bifurcation, attaining an average 6-mm increase in the distance between the superior mesenteric artery and main body within 4 years. Freedom from endoleak type IA was 95 ± 2% and 93 ± 3% after 1 and 4 years, respectively. The Anaconda main body ring system in its proximal portion flattens within the first year after EVAR, leading to an increase of 2 to 4 mm in the proximal landing zone's aortic diameter. The main body migrates slowly but continuously down toward the aortic bifurcation. Copyright © 2018 Society for Vascular Surgery. Published by Elsevier Inc. All rights reserved.

  11. CT findings of portal vein aneurysm

    International Nuclear Information System (INIS)

    Yang, Dal Mo; Chang, Mi Son; Yoon, Myung Hwan; Kim, Hak Soo; Kim, Hyung Sik; Chung, Hyo Sun; Chung, Jin Woo

    1999-01-01

    To describe the CT findings of portal vein aneurysm in eight patients. All patients included in this study (two men and six women) underwent CT examinations between October 1996 and June1998. Of these eight, three were suffering from hepatic disease and portal hypertension. We determined the location, shape, size, and characteristics of the lesions, and the presence or absence of portal vein anomaly. Seven patients had intrahepatic portal vein aneurysm (at the umbilical portion of the left portal vein in five patients, between the transverse and umbilical portion of the left portal vein in one, and at the bifurcation of the anterior and posterior branch of the right portal vein in one), while extrahepatic portal vein aneurysm, at the confluence of the superior mesenteric and splenic vein was found in only one. Lesions were cyst-shaped in seven cases and saccular in one, and showed well-circumscribed, markedly enhanced mass, which communicated with the portal vein and/or gives off major branches. Portal vein anomaly, in which the right anterior segmental portal vein originated from the umbilical portion of the left portal vein, was seen in three patients. In all three, intrahepatic portal vein aneurysm was present at the umbilical portion of the left portal vein, and in one, the umbilical protion of the left portal vein was located to the right of the Cantlic line. CT examination can help reveal portal vein aneurysm by detecting a well-circumscribed, markedly enhanced mass which communicates with the portal vein and/or gives off major branches

  12. Surveillance Duplex Ultrasonography of Stent Grafts for Popliteal Aneurysms.

    Science.gov (United States)

    Pineda, Danielle M; Troutman, Douglas A; Dougherty, Matthew J; Calligaro, Keith D

    2016-05-01

    Stent grafts, also known as covered stents, have become an increasingly acceptable treatment for popliteal artery aneurysms. However, endovascular exclusion confers lower primary patency compared to traditional open bypass and exclusion. The purpose of this study was to evaluate whether duplex ultrasonography (DU) can reliably diagnose failing stent grafts placed for popliteal artery aneurysms prior to occlusion. Between June 5, 2007, and March 11, 2014, 21 stent grafts (Viabahn; Gore, Flagstaff, Arizona) were placed in 19 patients for popliteal artery aneurysms. All patients had at least 1 follow-up duplex scan postoperatively. Mean follow-up was 28.9 months (9-93 months). Postoperative DU surveillance was performed in our Intersocietal Accreditation Commission noninvasive vascular laboratory at 1 week postprocedure and every 6 months thereafter. Duplex ultrasonography measured peak systolic velocities (PSVs) and ratio of adjacent PSVs (Vr) every 5 cm within the stent graft and adjacent arteries. We retrospectively classified the following factors as "abnormal DU findings": focal PSV > 300 cm/s, uniform PSVs 3.0. These DU criteria were derived from laboratory-specific data that we previously published on failing stent grafts placed for lower extremity occlusive disease. Four of the 21 stent grafts presented with symptomatic graft thrombosis within 6 months of a normal DU. Three of these 4 patients presented with rest pain and underwent thrombectomy (2) or vein bypass (1), and 1 elected for nonintervention for claudication. Our results suggest that surveillance DU using criteria established for grafts placed for occlusive disease may not be useful for predicting stent graft failure in popliteal artery aneurysms. © The Author(s) 2016.

  13. Open Repair of Mycotic Abdominal Aortic Aneurysms With Biological Grafts

    DEFF Research Database (Denmark)

    Heinola, Ivika; Sörelius, Karl; Wyss, Thomas R

    2018-01-01

    BACKGROUND: The treatment of mycotic abdominal aortic aneurysm requires surgery and antimicrobial therapy. Since prosthetic reconstructions carry a considerable risk of reinfection, biological grafts are noteworthy alternatives. The current study evaluated the durability, infection resistance......, and midterm outcome of biological grafts in treatment of mycotic abdominal aortic aneurysm. METHODS AND RESULTS: All patients treated with biological graft in 6 countries between 2006 and 2016 were included. Primary outcome measures were 30- and 90-day survival, treatment-related mortality, and reinfection...... rate. Secondary outcome measures were overall mortality and graft patency. Fifty-six patients (46 males) with median age of 69 years (range 35-85) were included. Sixteen patients were immunocompromised (29%), 24 (43%) had concomitant infection, and 12 (21%) presented with rupture. Bacterial culture...

  14. Adolescent External Iliac Artery Trauma: Recurrent Aneurysmal Dilatation of an Iliofemoral Saphenous Vein Graft Treated by Stent-Grafting

    International Nuclear Information System (INIS)

    Lenton, James; Davies, John; Homer-Vanniasinkam, S.; McPherson, Simon

    2008-01-01

    An adolescent male sustained a severe penetrating injury to the external iliac artery. Emergency surgical revascularization was with a reversed long saphenous vein interposition graft. The primary graft and the subsequent revision graft both became aneurysmal. The second graft aneurysm was successfully excluded by endovascular stent-grafts with medium-term primary patency. A venous graft was used initially rather than a synthetic graft to reduce the risk of infection and the potential problems from future growth. Aneurysmal dilatation of venous grafts in children and adolescents is a rare but recognized complication. To the best of our knowledge, exclusion of these aneurysms with stent-grafts has not been previously reported in the adolescent population.

  15. Endovascular Treatment of Descending Thoracic Aortic Aneurysms with the EndoFit Stent-Graft

    International Nuclear Information System (INIS)

    Saratzis, N.; Saratzis, Athanasios; Melas, N.; Ginis, G.; Lioupis, A.; Lykopoulos, D.; Lazaridis, J.; Kiskinis, Dimitrios

    2007-01-01

    Objective. To evaluate the mid-term feasibility, efficacy, and durability of descending thoracic aortic aneurysm (DTAA) exclusion using the EndoFit device (LeMaitre Vascular). Methods. Twenty-three (23) men (mean age 66 years) with a DTAA were admitted to our department for endovascular repair (21 were ASA III+ and 2 refused open repair) from January 2003 to July 2005. Results. Complete aneurysm exclusion was feasible in all subjects (100% technical success). The median follow-up was 18 months (range 8-40 months). A single stent-graft was used in 6 cases. The deployment of a second stent-graft was required in the remaining 17 patients. All endografts were attached proximally, beyond the left subclavian artery, leaving the aortic arch branches intact. No procedure-related deaths have occurred. A distal type I endoleak was detected in 2 cases on the 1 month follow-up CT scan, and was repaired with reintervention and deployment of an extension graft. A nonfatal acute myocardial infarction occurred in 1 patient in the sixth postoperative month. Graft migration, graft infection, paraplegia, cerebral or distal embolization, renal impairment or any other major complications were not observed. Conclusion. The treatment of DTAAs using the EndoFit stent-graft is technically feasible. Mid-term results in this series are promising

  16. Intracranial aneurysms: evaluation in 200 patients with spiral CT angiography

    International Nuclear Information System (INIS)

    Young, N.; Kingston, R.J.; Markson, G.; Dorsch, N.W.C.; McMahon, J.

    2001-01-01

    The goal of this study was to assess the usefulness of spiral CT angiography (CTA) with three- dimensional reconstructions in defining intracranial aneurysms, particularly around the Circle of Willis. Two hundred consecutive patients with angiographic and/or surgical correlation were studied between 1993 and 1998, with CTA performed on a GE HiSpeed unit and Windows workstation. The following clinical situations were evaluated: conventional CT suspicion of an aneurysm; follow-up of treated aneurysm remnants or of untreated aneurysms; subarachnoid haemorrhage (SAH) and negative angiography; family or past aneurysm history; and for improved definition of aneurysm anatomy. Spiral CTA detected 140 of 144 aneurysms, and an overall sensitivity of 97%, including 30 of 32 aneurysms 3 mm or less in size. In 38 patients with SAH and negative angiography, CTA found six of the seven aneurysms finally diagnosed. There was no significant artefact in 17 of 23 patients (74%) with clips. The specificity of CTA was 86% with 8 false-positive cases. Spiral CTA is very useful in demonstrating intracranial aneurysms. (orig.)

  17. Aneurysms of proximal pulmonary arteries: CT diagnosis and preoperative assessment

    International Nuclear Information System (INIS)

    Iula, G.; Ziviello, R.; Del Vecchio, W.

    1996-01-01

    We reviewed our experience with proximal pulmonary artery aneurysm (PPAA) to determine whether accurate preoperative evaluation (crucial to differential diagnosis and surgical planning) had been obtained on the basis of CT study alone. Three patients with PPAA were studied with contrast-enhanced CT. We evaluated the size and shape of PPAAs, their proximal and distal extent, eventual presence of intraluminal thrombi, dissection, perianeurysmal fibrosis, and rupture. The results were compared with surgical findings. In two patients the aneurysm involved the pulmonary trunk and both the right and left arteries origin. In one patient the aneurysm extended from the left artery origin to the hilum of the left lung. Contrast-enhanced CT alone allows detection of aneurysm in the pulmonary trunk, in right or left pulmonary arteries with precise preoperative evaluation of the extent, size, shape, and complications. The CT imaging was unable to establish the etiologic origin and presence of small intimal tears in PPAA. (orig.)

  18. CT findings of subarachnoid hemorrhage due to ruptured cerebral aneurysm

    International Nuclear Information System (INIS)

    Kim, Pyo Nyun; Bae, Won Kyung; Kim, Il Young; Lee, Kyung Soo; Lee, Byoung Ho; Kim, Ki Jung

    1990-01-01

    CT scans were analysed retrospectively in 130 patients with subarachnoid hemorrhage (SAH) due to ruptured cerebral aneurysm to evaluate the relationship of the locations of aneurysms and the patterns of hemorrhage. Hemorrhage corresponded to the site of aneurysmal origin in a general way and in more specific ways to anterior communicating and middle cerebral artery aneurysms when there was parenchymal or cisternal hemorrhage. In anterior communicating artery aneurysm, SAH in the interhemispheric fissure, both sylvian fissures, and basal cistern was usually noted and intracerebral hemorrhage in anteroinferior frontal lobe was sometimes associated. In cases of middle cerebral artery aneurysm, hemorrhage in the ipsilateral sylvian fissure, interhemispheric fissure, and ipsilateral basal cistern was usual. Intracerebral hemorrhage in lateral temporal lobe was sometimes associated. Posterior communicating artery aneurysm demonstrated SAH in the ipsilateral basal cistern or in entire cisternal spaces specifically, so with higher incidence of involvement of the quadrigeminal and superior cerebellar cistern than anterior cerebral or middle cerebral artery aneurysm. We suggest the locations of aneurysm might be predicted with patterns of SAH and / or associated intracerebral hemorrhage with CT

  19. Computational Fluid Dynamics: Hemodynamic Changes in Abdominal Aortic Aneurysm After Stent-Graft Implantation

    International Nuclear Information System (INIS)

    Frauenfelder, Thomas; Lotfey, Mourad; Boehm, Thomas; Wildermuth, Simon

    2006-01-01

    The aim of this study was to demonstrate quantitatively and qualitatively the hemodynamic changes in abdominal aortic aneurysms (AAA) after stent-graft placement based on multidetector CT angiography (MDCT-A) datasets using the possibilities of computational fluid dynamics (CFD). Eleven patients with AAA and one patient with left-side common iliac aneurysm undergoing MDCT-A before and after stent-graft implantation were included. Based on the CT datasets, three-dimensional grid-based models of AAA were built. The minimal size of tetrahedrons was determined for grid-independence simulation. The CFD program was validated by comparing the calculated flow with an experimentally generated flow in an identical, anatomically correct silicon model of an AAA. Based on the results, pulsatile flow was simulated. A laminar, incompressible flow-based inlet condition, zero traction-force outlet boundary, and a no-slip wall boundary condition was applied. The measured flow volume and visualized flow pattern, wall pressure, and wall shear stress before and after stent-graft implantation were compared. The experimentally and numerically generated streamlines are highly congruent. After stenting, the simulation shows a reduction of wall pressure and wall shear stress and a more equal flow through both external iliac arteries after stenting. The postimplantation flow pattern is characterized by a reduction of turbulences. New areas of high pressure and shear stress appear at the stent bifurcation and docking area. CFD is a versatile and noninvasive tool to demonstrate changes of flow rate and flow pattern caused by stent-graft implantation. The desired effect and possible complications of a stent-graft implantation can be visualized. CFD is a highly promising technique and improves our understanding of the local structural and fluid dynamic conditions for abdominal aortic stent placement

  20. Aortic Arch Aneurysms: Treatment with Extra anatomical Bypass and Endovascular Stent-Grafting

    International Nuclear Information System (INIS)

    Kato, Noriyuki; Shimono, Takatsugu; Hirano, Tadanori; Mizumoto, Toru; Ishida, Masaki; Fujii, Hideki; Yada, Isao; Takeda, Kan

    2002-01-01

    Endovascular repair of thoracic aortic aneurysms is emerging as an attractive alternative to surgical graft replacement. However,patients with aortic arch aneurysms are often excluded from the target of endovascular repair because of lack of suitable landing zones, especially at the proximal ones. In this paper we describe our method for treating patients with aortic arch aneurysms using a combination of extra anatomical bypass surgery and endovascular stent-grafting

  1. Transluminal endovascular stent-graft for the treatment of aortic aneurysms

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Do Yun; Chang, Byung Chul; Shim, Won Heum; Cho, Seung Yun; Chung, Nam Sik; Kwon, Hyuk Moon; Lee, Young Joon; Lee, Jong Tae [Yonsei University College of Medicine, Seoul (Korea, Republic of)

    1995-09-15

    The standard treatment for aortic aneurysms is surgical replacement with a prosthetic graft. Currently there is great interest in endoluminal intervention for treatment of aortic aneurysm. The purpose of this study was to evaluate the safety and effectiveness of endoluminally placed Stent-graft for the treatment of aortic aneurysms. Transluminal endovascular Stent-graft placements were attempted in 9 patients with infra-renal aortic aneurysms(n 6), thoracic aortic aneurysm(n = 1), and aortic dissection(n = 2). The endovascular Stent-grafts were custom-designed for each patient and were constructed of self-expandable modified Gianturco Stents covered with polytetrafluroethylene. The Stent-grafts were introduced through a 16-18 French sheath and expanded to 17-30 mm in diameter. The endovascular therapy was performed using a common femoral artery cutdown with local anesthesia. The endovascular Stent-graft deployment was achieved in 7 of 9 patients. Two cases failed deployment of the Stent-graft due to iliac artery stenosis and tortousity. There were complete thrombosis of the thoracic and infra-renal aortic aneurysm surround the Stent-graft in 3 patients, and persistent leak with partial thrombosis in 2. Two patients with aortic dissection were successfully treated by obliteration of entry tears. There were no major complication associated with Stent-graft placement. These preliminary results show that transluminal endovascular Stent-grafts offer great promise and good results. Further investigation is needed to establish its long-term safety and efficacy.

  2. Transluminal endovascular stent-graft for the treatment of aortic aneurysms

    International Nuclear Information System (INIS)

    Lee, Do Yun; Chang, Byung Chul; Shim, Won Heum; Cho, Seung Yun; Chung, Nam Sik; Kwon, Hyuk Moon; Lee, Young Joon; Lee, Jong Tae

    1995-01-01

    The standard treatment for aortic aneurysms is surgical replacement with a prosthetic graft. Currently there is great interest in endoluminal intervention for treatment of aortic aneurysm. The purpose of this study was to evaluate the safety and effectiveness of endoluminally placed Stent-graft for the treatment of aortic aneurysms. Transluminal endovascular Stent-graft placements were attempted in 9 patients with infra-renal aortic aneurysms(n 6), thoracic aortic aneurysm(n = 1), and aortic dissection(n = 2). The endovascular Stent-grafts were custom-designed for each patient and were constructed of self-expandable modified Gianturco Stents covered with polytetrafluroethylene. The Stent-grafts were introduced through a 16-18 French sheath and expanded to 17-30 mm in diameter. The endovascular therapy was performed using a common femoral artery cutdown with local anesthesia. The endovascular Stent-graft deployment was achieved in 7 of 9 patients. Two cases failed deployment of the Stent-graft due to iliac artery stenosis and tortousity. There were complete thrombosis of the thoracic and infra-renal aortic aneurysm surround the Stent-graft in 3 patients, and persistent leak with partial thrombosis in 2. Two patients with aortic dissection were successfully treated by obliteration of entry tears. There were no major complication associated with Stent-graft placement. These preliminary results show that transluminal endovascular Stent-grafts offer great promise and good results. Further investigation is needed to establish its long-term safety and efficacy

  3. Aneurismas y seudoaneurismas de injertos venosos coronarios Aneurysms and pseudo aneurysms from coronary venous grafts

    Directory of Open Access Journals (Sweden)

    Sergio Franco

    2005-04-01

    Full Text Available Los aneurismas y seudoaneurismas de injertos de vena safena aortocoronarios, son una complicación inusual de la cirugía de revascularización miocárdica. En este reporte se presenta el caso de un paciente de género masculino de 61 años de edad, quien sufrió un infarto del miocardio de la pared inferior 14 años atrás. La angiografía coronaria mostró enfermedad severa de dos vasos. Se realizó anastomosis de la arteria mamaria interna izquierda, al tercio medio de la descendente anterior e injerto de vena safena al tercio distal de la arteria coronaria derecha. En marzo de 2003, consultó por dolor anginoso. La radiografía de tórax reveló una masa paracardiaca derecha. La arteriografía coronaria mostró aneurisma del puente venoso a la arteria coronaria derecha. Durante la evolución presentó hemoptisis masiva; se hizo cirugía y se halló fístula de aneurisma de puente venoso coronario al lóbulo medio del pulmón derecho. En este artículo se hace una revisión de la etiología, los hallazgos clínicos, la metodología diagnóstica y el tratamiento actual de esta entidad. Hasta la fecha de esta publicación se reportan aproximadamente 60 casos en la literatura inglesa.Aorto-coronary aneurysms/pseudo aneurysms from saphenous vein grafts are an unusual complication of myocardial revascularization surgery. We report the case of a 61 years old male patient who had suffered an inferior wall myocardial infarction 14 years before. Coronary angiography showed severe two-vessel disease. Anastomosis of the left internal mammary artery to the mid third left anterior descendant artery and saphenous vein grafting to the distal third of the right coronary artery, were performed. In March 2003 he complains of anginous pain. Chest X ray showed a right paracardiac mass. Coronary arteriography revealed an aneurysm of the venous bypass graft to the right coronary artery. During the evolution, the patient presents massive hemoptysis, requiring

  4. Thrombosed aneurysm of saphenous vein coronary artery bypass grafting

    Energy Technology Data Exchange (ETDEWEB)

    Queiroz, Rodolfo Mendes; Nastri Filho, Rogerio; Ferez, Marcus Antonio; Costa, Mauro Jose Brandao da; Laguna, Claudio Benedini; Valentin, Marcus Vinicius Nascimento, E-mail: rod_queiroz@hotmail.com [Documenta - Hospital Sao Francisco, Ribeirao Preto, SP (Brazil). Departamento de Radiologia e Diagnostico por Imagem; Hospital Sao Francisco, Ribeirao Preto, SP (Brazil). Centro de Terapia Intensiva

    2017-06-15

    We describe the case of a male patient, aged 76 years, referred for cardiac investigation due to retrosternal chest pain and dyspnea. He had a history of acute myocardial infarction and angioplasties in the last 30 years, including a saphenous vein coronary artery bypass grafting (SVCABG). Echocardiogram showed hypoechoic oval formation near the right ventricle, suggesting a pericardial cyst. Computed angiotomography revealed a predominantly fusiform and thrombosed aneurysmal dilation of the SVCABG to the right coronary artery. SVCABG aneurysms are very rare and potentially fatal. They usually appear in the late postoperative period, and patients are often asymptomatic. On radiography, it is frequently presented as enlargement of the mediastinum, with echocardiography, computed tomography and magnetic resonance imaging being very useful for diagnosis. Coronary angiography is the gold standard to detect these cases. Our report illustrates a rare situation arising late from a relatively common surgery. Due to its severity, proper recognition in the routine assessment of patients with a similar history is essential. (author)

  5. Evolution of the Proximal Sealing Rings of the Anaconda Stent-Graft After Endovascular Aneurysm Repair

    NARCIS (Netherlands)

    Koenrades, Maaike A.; Klein, Almar; Leferink, Anne M.; Slump, Cornelis H.; Geelkerken, Robert H.

    2018-01-01

    Purpose: To provide insight into the evolution of the saddle-shaped proximal sealing rings of the Anaconda stent-graft after endovascular aneurysm repair (EVAR). Methods: Eighteen abdominal aortic aneurysm patients were consecutively enrolled in a single-center, prospective, observational cohort

  6. Coil embolization of a false aneurysm with aorto-cutaneous fistula after prosthetic graft replacement of the ascending aorta

    International Nuclear Information System (INIS)

    Miguel, Bruno; Camilleri, Lionel; Gabrillargues, Jean; Macheda, Bruno; Kubota, Hiroshi; Ravel, Anne; Riberolles, Charles de; Boyer, Louis

    2000-01-01

    Aim: To report palliative embolization of a false aneurysm over the distal suture line of an ascending aorta graft replacement. Material and Method: A 78-year-old male patient was admitted for increasing bleeding of a chronic Manubrium ulceration, 20 months after coronary artery bypass complicated by perioperative ascending aorta dissection requiring prosthetic graft replacement. One month later, he underwent epiploplasty for a mediastinitis followed by long-term antibiotic therapy. Five months later, he presented with a Manubrium ulceration of the sternotomy. Spiral computerized tomography (CT) and aortography revealed a 20 mm anterior peri-prosthetic false aneurysm with a wide neck. Advanced age, active mediastinitis and patient's objection led us to perform percutaneous occlusion according to the Moret remodeling technique while protecting the coils release with balloon catheter inflation. Results: No post-operative complication was observed and at 1-year follow-up the patient was doing well with no recurrent bleeding. Magnetic resonance imaging (MRI) and spiral CT controls confirmed coils stability without any internal flow. Conclusion: Percutaneous coils embolization of a large false aneurysm in the ascending aorta can be a palliative treatment in a surgically unsuited patient

  7. Acute Symptomatic Abdominal Aortic Aneurysm Secondary to Endovascular Stent Graft Associated Type II Endoleak

    Directory of Open Access Journals (Sweden)

    Karen Ka Leung Chan

    2006-07-01

    Full Text Available Endovascular abdominal aneurysm repair (EVAR is popular because of its low invasiveness and feasibility for high-risk patients. Endoleak is common after EVAR and is characterized by blood flow within the aneurysm sac but outside the stent graft. Type II or collateral endoleak commonly results from retrograde filling of the aneurysm from collateral visceral vessels, lumbar, inferior mesenteric, accessory renal or sacral arteries. Collateral leaks are generally thought to be benign and over half of the early leaks will seal spontaneously. Sporadically, collateral endoleak could lead to aneurysm sac pressurization and place the patient at ongoing risk of rupture. Herein, we report an uncommon case of early post-stent graft placement symptomatic abdominal aortic aneurysm associated with type II endoleak.

  8. Prediction of parent artery of anterior communicating artery aneurysm on CT angiography

    International Nuclear Information System (INIS)

    Chung, Jin Young; Han, Tae Il; Kim, Dae Hong; Han, Hyun Young; Kim, Hyun Jung; Song, Mun Kab

    1999-01-01

    To determine whether CT angiography can predict the parent artery of an anterior communicating aneurysm on the basis of characteristics of the aneurysm and precommunication anterior cerebral artery. Eighteen patients with anterior communication aneurysm were studied prospectively using CT angiography and conventional angiography. The parent artery of an aneurysm was predicted by evaluating aneurysm neck location, direction of aneurysm projection, and size of the precommunicating anterior cerebral artery, as seen on CT angiography. A somatom Plus-4 spiral CT scanner was used and shaded-surface display three-dimensional images were constructed. Aneurysm neck was located near the parent artery in 12 cases(66.7%), and aneurysm projection was against the parent artery in 11 cases(61.1%). The parent artery of the anterior cerebral artery was larger in 15 cases(83.3%), including ten cases of hypoplasia or agenesis of the contralateral anterior cerebral artery. In 17 of 18 aneurysms(94.4%) the parent artery seen on DSA was correctly predicted by CT angiography. The parent artery of an anterior communicating aneurysm can be predicted by evaluating aneurysm neck location, direction of aneurysm projection, and precommunicating anterior cerebral artery, as seen on CT angiography

  9. Automatic segmentation of the wire frame of stent grafts from CT data.

    NARCIS (Netherlands)

    Klein, A.; Vliet, J.A. van der; Oostveen, L.J.; Hoogeveen, Y.L.; Schultze Kool, L.J.; Renema, W.K.J.; Slump, C.H.

    2012-01-01

    Endovascular aortic replacement (EVAR) is an established technique, which uses stent grafts to treat aortic aneurysms in patients at risk of aneurysm rupture. Late stent graft failure is a serious complication in endovascular repair of aortic aneurysms. Better understanding of the motion

  10. Importance of stent-graft design for aortic arch aneurysm repair

    Directory of Open Access Journals (Sweden)

    C Singh

    2017-02-01

    Full Text Available Aneurysm of the aorta is currently treated by open surgical repair or endovascular repair. However, when the aneurysm occurs in regions between the aortic arch and proximal descending aorta, it can be a complex pathology to treat due to its intricate geometry. When complex aortic aneurysms are treated with the conventional procedures, some of the patients present with significant post-operative complications and high mortality rate. Consequently, a clinically driven hybrid innovation known as the frozen elephant trunk procedure was introduced to treat complex aortic aneurysms. Although this procedure significantly reduces mortality rate and operating time, it is still associated with complications such as endoleaks, spinal cord ischemia, renal failure and stroke. Some of these complications are consequences of a mismatch in the biomechanical behaviour of the stent-graft device and the aorta. Research on complex aneurysm repair tended to focus more on the surgical procedure than the stent-graft design. Current stent-graft devices are suitable for straight vessels. However, when used to treat aortic aneurysm with complex geometry, these devices are ineffective in restoring the normal biological and biomechanical function of the aorta. A stent-graft device with mechanical properties that are comparable with the aorta and aortic arch could possibly lead to fewer post-operative complications, thus, better outcome for patients with complex aneurysm conditions. This review highlights the influence stent-graft design has on the biomechanical properties of the aorta which in turn can contribute to complications of complex aneurysm repair. Design attributes critical for minimising postoperative biomechanical mismatch are also discussed.

  11. Early and late results of graft replacement for dissecting aneurysm of thoracoabdominal aorta in patients with Marfan syndrome.

    Science.gov (United States)

    Omura, Atsushi; Tanaka, Akiko; Miyahara, Shunsuke; Sakamoto, Toshihito; Nomura, Yoshikatsu; Inoue, Takeshi; Oka, Takanori; Minami, Hitoshi; Okada, Kenji; Okita, Yutaka

    2012-09-01

    When treating dissecting aneurysm of the thoracoabdominal aorta surgically in patients with Marfan syndrome, we have usually performed graft replacement- including the entire thoracoabdominal aorta and reconstruction of all visceral branches, even if dilatation is mild in some segments-to avoid further aortic operations in the follow-up period. From October 1999 through July 2011, 20 consecutive patients with Marfan syndrome underwent repair of dissecting aneurysm of the thoracoabdominal aorta (median age, 45 years; range, 19-65 years). All patients underwent surgical intervention with cerebrospinal fluid (CSF) drainage and distal aortic and selective organ perfusion. Deep hypothermia was used in 13 patients for spinal cord protection. No in-hospital mortality was observed. One patient had temporary spinal cord ischemia but was fully recovered by discharge. Other complications included exploration for bleeding (n=1), prolonged ventilation (n=1), and graft infection (n=1). At a mean follow-up of 54 months (range, 9-129 months), 1 patient had died of interstitial pneumonia at 38 months postoperatively. Survival at 8% years was 91.2±9.0%. Two patients required additional aortic procedures (total arch replacement and aortic valve-sparing surgery). Actuarial rate of freedom from aortic operations at 8 years was 83.9%±10.5%, but no patient needed required repeated thoracotomy for an aortic procedure. Neither false nor patch aneurysms were observed using computed tomography (CT) during follow-up surveillance. Graft replacement for dissecting aneurysm of the thoracoabdominal aorta in Marfan syndrome offers good early and long-term results. We believe total aortic replacement including the entire thoracoabdominal aorta and reconstruction of all visceral arteries should be recommended for selected patients with Marfan syndrome. Copyright © 2012 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.

  12. Coronary artery aneurysm after stent implantation: acute and long-term results after percutaneous treatment with a stent graft.

    Science.gov (United States)

    Rubartelli, Paolo; Terzi, Giacomo; Borgo, Lorenzo; Giachero, Corinna

    2002-03-01

    A patient with unstable angina was treated with elective Palmaz-Schatz stent implantation on a focal stenosis of the left circumflex artery. One year later, a large (13 mm in diameter) coronary artery aneurysm was diagnosed at angiography in the stented site. Intravascular ultrasound examination confirmed the presence of a true aneurysm located at the proximal end of the stent. The aneurysm was successfully treated with a Jostent Graft (Jomed Implantate) consisting of two slotted tube stainless steel stents supporting a polytetrafluoroethylene tube. The stent graft was implanted under intravascular ultrasound guidance. The 18-month angiographic follow-up showed good patency of the stent graft and complete exclusion of the aneurysm.

  13. Comparison of arterial stiffness and microcirculatory changes following abdominal aortic aneurysm grafting.

    LENUS (Irish Health Repository)

    Moloney, M A

    2012-02-01

    BACKGOUND: Abdominal aortic aneurysm (AAA) surgery provides a unique opportunity to study the impact of arterial stiffness on central haemodynamics, reflected in augmentation index (AI). The aneurysmal aorta is significantly stiffer than undilated age-matched aorta. AIM: We investigated whether replacement of an aneurysmal aorta with a compliant graft would result in a decrease in AI, which would thus decrease myocardial workload parameters. METHODS: Patients undergoing elective open or endovascular AAA repair were assessed with applanation tonometry and laser fluximetry pre-operatively, immediately and long-term post-operatively. RESULTS: Replacement of a small segment of abnormal conduit vessel resulted in improvements in AI, demonstrating that arterial stiffness can be surgically manipulated. CONCLUSIONS: These results reflect a decreased myocardial workload post-aortic grafting. This decrease in AI is important from a risk factor management perspective, and arterial stiffness should become a further recognised and screened for risk factor in patients with known aneurysmal disease.

  14. Comparison of arterial stiffness and microcirculatory changes following abdominal aortic aneurysm grafting.

    LENUS (Irish Health Repository)

    Moloney, M A

    2010-11-11

    BACKGOUND: Abdominal aortic aneurysm (AAA) surgery provides a unique opportunity to study the impact of arterial stiffness on central haemodynamics, reflected in augmentation index (AI). The aneurysmal aorta is significantly stiffer than undilated age-matched aorta. AIM: We investigated whether replacement of an aneurysmal aorta with a compliant graft would result in a decrease in AI, which would thus decrease myocardial workload parameters. METHODS: Patients undergoing elective open or endovascular AAA repair were assessed with applanation tonometry and laser fluximetry pre-operatively, immediately and long-term post-operatively. RESULTS: Replacement of a small segment of abnormal conduit vessel resulted in improvements in AI, demonstrating that arterial stiffness can be surgically manipulated. CONCLUSIONS: These results reflect a decreased myocardial workload post-aortic grafting. This decrease in AI is important from a risk factor management perspective, and arterial stiffness should become a further recognised and screened for risk factor in patients with known aneurysmal disease.

  15. Innovative chimney-graft technique for endovascular repair of a pararenal abdominal aortic aneurysm.

    Science.gov (United States)

    Galiñanes, Edgar Luis; Hernandez-Vila, Eduardo A; Krajcer, Zvonimir

    2015-02-01

    After abdominal aortic aneurysm repair, progressive degeneration of the aneurysm can be challenging to treat. Multiple comorbidities and previous operations place such patients at high risk for repeat surgery. Endovascular repair is a possible alternative; however, challenging anatomy can push the limits of available technology. We describe the case of a 71-year-old man who presented with a 5.3-cm pararenal aneurysm 4 years after undergoing open abdominal aortic aneurysm repair. To avoid reoperation, we excluded the aneurysm by endovascular means, using visceral-artery stenting, a chimney-graft technique. Low-profile balloons on a monorail system enabled the rapid exchange of coronary wires via a buddy-wire technique. This novel approach facilitated stenting and simultaneous angioplasty of multiple visceral vessels and the abdominal aorta.

  16. Expanding arch aneurysm causing a "kink" in a Bentall graft and heart failure.

    Science.gov (United States)

    Al-Mohaissen, Maha A; Skarsgard, Peter; Khoo, Clarence; Virani, Sean A; Munt, Brad; Leipsic, Jonathon; Ignaszewski, Andrew

    2012-07-01

    Marfan syndrome is associated with a high incidence of aortic root aneurysm and life-threatening aortic dissection. With the successful use of surgical aortic root replacement, dissection-related mortality has been significantly reduced. We present the case of a patient with Marfan syndrome who presented with heart failure secondary to an unusual graft-related complication 14 years after a Bentall procedure. Investigations revealed a supra-aortic stenosis resulting from a kink in the Bentall graft caused by pressure from an expanding aortic arch aneurysm. The patient underwent surgery with improvement in his ejection fraction and heart failure symptoms.

  17. Endovascular Aortic Aneurysm Repair with Chimney and Snorkel Grafts: Indications, Techniques and Results

    Energy Technology Data Exchange (ETDEWEB)

    Patel, Rakesh P., E-mail: rpatel9@nhs.net [Northwick Park Hospital, Department of Vascular Radiology (United Kingdom); Katsargyris, Athanasios, E-mail: kthanassos@yahoo.com; Verhoeven, Eric L. G., E-mail: Eric.Verhoeven@klinikum-nuernberg.de [Klinikum Nuernberg, Department of Vascular and Endovascular Surgery (Germany); Adam, Donald J., E-mail: donald.adam@tiscali.co.uk [Heartlands Hospital, Department of Vascular Surgery (United Kingdom); Hardman, John A., E-mail: johnhardman@doctors.org.uk [Royal United Hospital Bath, Department of Vascular Radiology (United Kingdom)

    2013-12-15

    The chimney technique in endovascular aortic aneurysm repair (Ch-EVAR) involves placement of a stent or stent-graft parallel to the main aortic stent-graft to extend the proximal or distal sealing zone while maintaining side branch patency. Ch-EVAR can facilitate endovascular repair of juxtarenal and aortic arch pathology using available standard aortic stent-grafts, therefore, eliminating the manufacturing delays required for customised fenestrated and branched stent-grafts. Several case series have demonstrated the feasibility of Ch-EVAR both in acute and elective cases with good early results. This review discusses indications, technique, and the current available clinical data on Ch-EVAR.

  18. Comparison of CT angiography and digital subtraction angiography in the evaluation of intracranial aneurysmal neck

    International Nuclear Information System (INIS)

    Kim, Yoo Kyung; Baik, Seung Kug; Shin, Mi Jeong; Choi, Han Yong

    2001-01-01

    To compare the usefulness of three-dimensional multislice CT angiography(CTA) and digital subtraction angiography (DSA) in the evaluation of intracranial aneurysmal neck. Nineteen patients with intracranial aneurysm (23 cases) underwent DSA and subsequent CTA. Using a multislice CT scanner and the SSD(shaded surface display) technique, clipping, cutting and the MPR technique, three-dimensional images were obtained. These were (a) external, (b) internal, from the direction of the parent artery, (c) internal, from the direction of the aneurysmal dome, and (d) an aneurysmal cutting image. The CTA findings were retrospectively compared with the DSA images. Twenty aneurysms were small and three were large. In eleven cases aneurysm neck was small, in nine it was wide, and in three it was relatively wide. For aneurysmal neck evaluation, CTA was superior to DSA in six of nine wide-neck aneurysms and all three large-sized wide-neck aneurysms. In small neck aneurysms 8 of 11 cases and in relatively wide neck all 3 cases showed similarly good images by both modalities. Of the 23 cases demonstrated by four different images, 14 cases showed the best image in internal image from parent artery direction and 6 cases showed similarly good image in both aneurysmal cutting image and internal image from parent artery direction. In the evaluation of wide neck aneurysms, 7 of 9 cases showed the best image at internal image from parent artery direction, compared with other three different images. In two cases of aneurysms, calcification was visible in the aneurysmal wall, so it was difficult to evaluate the aneurysmal neck. CTA was superior to DSA in the evaluating the intracranial aneurysmal neck. CTA maybe an additional available modality to evaluate the aneurysmal neck which is difficult to detect by the DSA. And the information of intracranial aneurysmal neck through CTA will be of value in surgical and endovascular treatment

  19. Open Versus Endovascular Stent Graft Repair of Abdominal Aortic Aneurysms

    DEFF Research Database (Denmark)

    Firwana, Belal; Ferwana, Mazen; Hasan, Rim

    2014-01-01

    We performed an analysis to assess the need for conducting additional randomized controlled trials (RCTs) comparing open and endovascular aneurysm repair (EVAR) for abdominal aortic aneurysm (AAA). Trial sequential analysis (TSA) is a statistical methodology that can calculate the required inform...

  20. Early and midterm outcomes of open stent-graft treatment for distal aortic arch aneurysm

    International Nuclear Information System (INIS)

    Yamada, Kazunori; Mochizuki, Takaaki; Tsubota, Hideki; Funamoto, Masaki

    2008-01-01

    The aim of this study was to investigate early and late outcomes for open stent-graft treatment, which was introduced as a less-invasive technique for thoracic aortic aneurysm of the distal arch, and to clarify the validity of and indications for this treatment. We retrospectively investigated 38 patients with thoracic aortic aneurysm of the distal arch who underwent open stent-graft placement at our hospital between June 2000 and September 2006. Five patients died in hospital (hospital mortality 13.2%). Age at the time of surgery and onset of postoperative paraplegia were identified as risk factors. Four patients (10.5%) had postoperative paraplegia, but no significant risk factors were seen. The size of the aneurysm was clearly reduced in 18 of the 25 patients (75.8%), in whom computed tomography was performed after discharge, and late outcomes were good. Mural thrombus thickness on the stent landing zone of <4 mm was a predictor for aneurysm shrinkage. Seven patients died during the late period, and the 5-year survival rate among hospital survivors was 80.1%. Early outcomes for open stent-graft are not necessarily good, and late survival is also not excellent. Open stent-graft thus cannot be regarded as an ideal technique for all patients with distal aortic arch aneurysm. However, after aneurysm shrinkage was confirmed during the early period, late outcomes were good. Absence of thick mural thrombus on the stent landing zone may represent a good indication for open stent-graft surgery. (author)

  1. Role of CT for dissecting aneurysm of aorta

    Energy Technology Data Exchange (ETDEWEB)

    Chung, Hee Tae; Kim, Hong Gil; Park, Choong Ki; Lee, Young Joong; Yoon, Jong Sup [College of Medicine, Hallym University, Chunchun (Korea, Republic of)

    1987-06-15

    During a three years period, 11 patients with clinically suspected aortic dissection were diagnosed by CT as the primary mode of investigation. Chest roentgenography was performed in all 11 patients and ultrasonography was performed in 2 patients. None of them obtained aortography. The authors analyzed them and obtained the results as follows : 1. 7 cases were female and 4 male, with a mean age of 65 years (range 53-75 years) 2. All of them suffered from hypertension. The most consistent clinical symptom was severe tearing chest pain which was radiating to back. ECG revealed the findings of LVH in all 11 cases. 5 cases were expired within 2 weeks and 6 cases treated medically with symptomatic improvement. 3. Chest roentgenography revealed suggestive signs of dissecting aortic aneurysm such as widening of superior mediastinum, shifting of trachea to the right side, obliteration of aortic knob, double aortic knob, displacement of intimal calcification and pleural effusion. 4. CT findings proffered us useful information which were double channel with intimal flap, displacement of intimal calcification, thrombosis, increased diameter of aorta, pleural and pericardial effusion, and narrowness of true lumen. 5. The authors recommend a CT study as the most important preliminary examination in all suspected cases of dissecting aortic aneurysm even though it has some limitation.

  2. Role of CT for dissecting aneurysm of aorta

    International Nuclear Information System (INIS)

    Chung, Hee Tae; Kim, Hong Gil; Park, Choong Ki; Lee, Young Joong; Yoon, Jong Sup

    1987-01-01

    During a three years period, 11 patients with clinically suspected aortic dissection were diagnosed by CT as the primary mode of investigation. Chest roentgenography was performed in all 11 patients and ultrasonography was performed in 2 patients. None of them obtained aortography. The authors analyzed them and obtained the results as follows : 1. 7 cases were female and 4 male, with a mean age of 65 years (range 53-75 years) 2. All of them suffered from hypertension. The most consistent clinical symptom was severe tearing chest pain which was radiating to back. ECG revealed the findings of LVH in all 11 cases. 5 cases were expired within 2 weeks and 6 cases treated medically with symptomatic improvement. 3. Chest roentgenography revealed suggestive signs of dissecting aortic aneurysm such as widening of superior mediastinum, shifting of trachea to the right side, obliteration of aortic knob, double aortic knob, displacement of intimal calcification and pleural effusion. 4. CT findings proffered us useful information which were double channel with intimal flap, displacement of intimal calcification, thrombosis, increased diameter of aorta, pleural and pericardial effusion, and narrowness of true lumen. 5. The authors recommend a CT study as the most important preliminary examination in all suspected cases of dissecting aortic aneurysm even though it has some limitation

  3. Various complications of abdominal aortic aneurysm : CT findings

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Sang Hoon; Byun, Jae Young; Kim, Bum Soo; Kim, Euy Neyung; Yoon, Yeo Dong; Kim, Ki Tae; Lee, Jae Mun; Shinn, Kyung Sub [The Catholic Univ. of Korea, College of Medicine, Seoul (Korea, Republic of)

    1997-03-01

    To evaluate on abdominal CT the type and incidence of various complications of abdominal aortic aneurysm (AAA). Twenty six suspected cases of AAA were confirmed by operation(n=21) and by CT(n=5). The etiology, size, shape and incidence of various complications of AAA were then retrospectively evaluated. In addition, post-operative complications were also evaluated in five cases. The etiology of the aneurysm was atherosclerotic in 18 cases and mycotic in three;it showed the presence of Behcet disease in three cases, of tuberculosis in one, and of Marfan syndrome in one. Among the 18 fusiform AAA, the mean maximum diameter of ruptured AAA(7.5{+-}3cm, n=3) was significantly larger than that of unruptured AAA(4.9{+-}1.6cm, n=15) (p<0.05). The saccular type was much more likely to rupture than the fusiform type(p<0.00001). Out of the eight saccular AAA, seven ruptured ; their mean maximum diameter was 3.9{+-}1.3cm This was significantly smaller than that of ruptured fusiform aneurysm(p<0.05). The most common complication was rupture, and occurred ten of 26 cases(38%). Others included hydronephrosis in three cases, bowel infarction in one, and perianeurysmal retroperitoneal fibrosis in one case. Various post-oper-ative complications developed in five patients; these comprised periprosthetic pseudoaneurysm with hematoma (two cases), bowel ischemia (one), focal renal infarction (one), and secondary aorticoduodenal fistula (one). The most common complication of AAA was rupture, the rate of which was much higher in the saccular type with smaller size than the fusiform type. Other various and uncommon complications were observed. CT was helpful in detecting complications arising from AAA and in planning its treatment.

  4. Various complications of abdominal aortic aneurysm : CT findings

    International Nuclear Information System (INIS)

    Lee, Sang Hoon; Byun, Jae Young; Kim, Bum Soo; Kim, Euy Neyung; Yoon, Yeo Dong; Kim, Ki Tae; Lee, Jae Mun; Shinn, Kyung Sub

    1997-01-01

    To evaluate on abdominal CT the type and incidence of various complications of abdominal aortic aneurysm (AAA). Twenty six suspected cases of AAA were confirmed by operation(n=21) and by CT(n=5). The etiology, size, shape and incidence of various complications of AAA were then retrospectively evaluated. In addition, post-operative complications were also evaluated in five cases. The etiology of the aneurysm was atherosclerotic in 18 cases and mycotic in three;it showed the presence of Behcet disease in three cases, of tuberculosis in one, and of Marfan syndrome in one. Among the 18 fusiform AAA, the mean maximum diameter of ruptured AAA(7.5±3cm, n=3) was significantly larger than that of unruptured AAA(4.9±1.6cm, n=15) (p<0.05). The saccular type was much more likely to rupture than the fusiform type(p<0.00001). Out of the eight saccular AAA, seven ruptured ; their mean maximum diameter was 3.9±1.3cm This was significantly smaller than that of ruptured fusiform aneurysm(p<0.05). The most common complication was rupture, and occurred ten of 26 cases(38%). Others included hydronephrosis in three cases, bowel infarction in one, and perianeurysmal retroperitoneal fibrosis in one case. Various post-oper-ative complications developed in five patients; these comprised periprosthetic pseudoaneurysm with hematoma (two cases), bowel ischemia (one), focal renal infarction (one), and secondary aorticoduodenal fistula (one). The most common complication of AAA was rupture, the rate of which was much higher in the saccular type with smaller size than the fusiform type. Other various and uncommon complications were observed. CT was helpful in detecting complications arising from AAA and in planning its treatment

  5. Stent fractures in the Hemobahn/Viabahn stent graft after endovascular popliteal aneurysm repair

    NARCIS (Netherlands)

    Tielliu, Ignace F. J.; Zeebregts, Clark J.; Vourliotakis, George; Bekkema, Foppe; van den Dungen, Jan J. A. M.; Prins, Ted R.; Verhoeven, Eric L. G.

    Objective: During the last decade, endovascular repair of popliteal artery aneurysms (PAAs) has become a valid alternative to open repair. This study analyzes the incidence and origin of stein graft fractures after endovascular repair, its impact on patency, and strategies to prevent fractures.

  6. Comparative evaluation of cerebral aneurysms with selective arterially enhanced CT and DSA

    International Nuclear Information System (INIS)

    Vanderschelden, P.; Flandroy, P.; Dondelinger, R.F.; Martin, D.; Lenelle, J.

    1998-01-01

    The purpose of our study was to compare selective arterially enhanced spiral computed tomographs (ACT) with digital subtraction angiographies (DSA) in the presurgical assessment of cerebral aneurysms. A total of 24 aneurysms in 18 patients were explored in a prospective study by ACT and DSA, using an interactive combined CT-angiography suite. Dimensions of the aneurysm, its relation to the parent vessel, and the aneurysmal index were defined on DSA and on surface-shaded display of 3D reformatted images obtained from ACT. Results were correlated with surgical findings. Three aneurysms suspected on DSA were not confirmed by ACT. One fusiform aneurysm suspected on DSA corresponded to a sacciform aneurysm on ACT. Surgical findings confirmed 20 sacciform aneurysms. The aneurysmal index could be measured in all 20 cases of sacciform aneurysms on ACT and could not be determined with confidence in 55 % of the cases on DSA. DSA and ACT gave identical results in 35 % of cases. In 10 %, the index measured by ACT was superior to that determined by DSA for aneurysms which had a diameter of less than 3 mm. In conclusion, the combination of DSA and ACT improved the results of DSA alone. ACT is a reliable method to measure the aneurysmal index in aneurysms with a diameter superior to 3 mm. (orig.)

  7. Maximum Diameter Measurements of Aortic Aneurysms on Axial CT Images After Endovascular Aneurysm Repair: Sufficient for Follow-up?

    International Nuclear Information System (INIS)

    Baumueller, Stephan; Nguyen, Thi Dan Linh; Goetti, Robert Paul; Lachat, Mario; Seifert, Burkhardt; Pfammatter, Thomas; Frauenfelder, Thomas

    2011-01-01

    Purpose: To assess the accuracy of maximum diameter measurements of aortic aneurysms after endovascular aneurysm repair (EVAR) on axial computed tomographic (CT) images in comparison to maximum diameter measurements perpendicular to the intravascular centerline for follow-up by using three-dimensional (3D) volume measurements as the reference standard. Materials and Methods: Forty-nine consecutive patients (73 ± 7.5 years, range 51–88 years), who underwent EVAR of an infrarenal aortic aneurysm were retrospectively included. Two blinded readers twice independently measured the maximum aneurysm diameter on axial CT images performed at discharge, and at 1 and 2 years after intervention. The maximum diameter perpendicular to the centerline was automatically measured. Volumes of the aortic aneurysms were calculated by dedicated semiautomated 3D segmentation software (3surgery, 3mensio, the Netherlands). Changes in diameter of 0.5 cm and in volume of 10% were considered clinically significant. Intra- and interobserver agreements were calculated by intraclass correlations (ICC) in a random effects analysis of variance. The two unidimensional measurement methods were correlated to the reference standard. Results: Intra- and interobserver agreements for maximum aneurysm diameter measurements were excellent (ICC = 0.98 and ICC = 0.96, respectively). There was an excellent correlation between maximum aneurysm diameters measured on axial CT images and 3D volume measurements (r = 0.93, P < 0.001) as well as between maximum diameter measurements perpendicular to the centerline and 3D volume measurements (r = 0.93, P < 0.001). Conclusion: Measurements of maximum aneurysm diameters on axial CT images are an accurate, reliable, and robust method for follow-up after EVAR and can be used in daily routine.

  8. Mycotic Aneurysm of the Celiac Trunk: From Early CT Sign to Rupture

    International Nuclear Information System (INIS)

    Serafino, Gianpiero; Vroegindeweij, Dammis; Boks, Simone; Harst, Erwin van der

    2005-01-01

    We present a case of the rapid development and rupture of a mycotic celiac trunk aneurysm. Initiallyon multislice computed tomography (ms-CT) there was a normal celiac trunk with minimal haziness of the surrounding fat. Only 2 weeks later the patient went into hypovolemic shock due to a ruptured celiac aneurysm. Although aneurysms of the visceral arteries are rare, they are of major clinical importance as they carry a life-threatening risk of rupture. This case illustrates the use of ms-CT in detecting and evaluating visceral aneurysms, in order to prevent emergency operation

  9. Ten-Year Follow-Up of Endovascular Aneurysm Treatment with Talent Stent-Grafts

    International Nuclear Information System (INIS)

    Pitton, Michael B.; Scheschkowski, Tobias; Ring, Markus; Herber, Sascha; Oberholzer, Katja; Leicher-Dueber, Annegret; Neufang, Achim; Schmiedt, Walther; Dueber, Christoph

    2009-01-01

    The purpose of this study was to evaluate the clinical results, complications, and secondary interventions during long-term follow-up after endovascular aneurysm repair (EVAR) and to investigate the impact of endoleak sizes on aneurysm shrinkage. From 1997 to March 2007, 127 patients (12 female, 115 male; age, 73.0 ± 7.2 years) with abdominal aortic aneurysms were treated with Talent stent-grafts. Follow-up included clinical visits, contrast-enhanced MDCT, and radiographs at 3, 6, and 12 months and then annually. Results were analyzed with respect to clinical outcome, secondary interventions, endoleak rate and management, and change in aneurysm size. There was no need for primary conversion surgery. Thirty-day mortality was 1.6% (two myocardial infarctions). Procedure-related morbidity was 2.4% (paraplegia, partial infarction of one kidney, and inguinal bleeding requiring surgery). Mean follow-up was 47.7 ± 34.2 months (range, 0-123 months). Thirty-nine patients died during follow-up; three of the deaths were related to aneurysm (aneurysm rupture due to endoleak, n = 1; secondary surgical reintervention n = 2). During follow-up, a total of 29 secondary procedures were performed in 19 patients, including 14 percutaneous procedures (10 patients) and 15 surgical procedures (12 patients), including 4 cases with late conversion to open aortic repair (stent-graft infection, n = 1; migration, endoleak, or endotension, n = 3). Overall mean survival was 84.5 ± 4.7 months. Mean survival and freedom from any event was 66.7 ± 4.5 months. MRI depicted significantly more endoleaks compared to MDCT (23.5% vs. 14.3%; P 10% of the aneurysm area were associated with reduced aneurysm shrinkage compared to no endoleaks or <10% endoleaks (Δ at 3 years, -1.8% vs. -12.0%; P < 0.05). In conclusion, endovascular aneurysm treatment with Talent stent-grafts demonstrated encouraging long-term results with moderate secondary intervention rates. Primary occlusion of all aortic side

  10. Resolved Abdominal Aortic Aneurysms Following Stent Graft Treatment: A Report of Five Cases

    International Nuclear Information System (INIS)

    Rimon, Uri; Garniek, Alexander; Golan, Gil; Bensaid, Paul; Galili, Yair; Schneiderman, Jacob; Morag, Benyamina

    2004-01-01

    Complete aneurysm resolution is the hallmark of successful endoluminal stent-graft treatment. We describe 5 patients in whom an abdominal aortic aneurysm (AAA) disappeared completely at mid-term follow-up after endovascular stent-graft placement. We reviewed 45 patients (43 men and 2 women) who underwent AAA repair using an endovascular technique, from April 1997 to December 2001. Mean AAA diameter was 58.3 mm. On 48-month follow-up, 12 aneurysms had not changed in size, 4 had grown, 16 had shrunk, and 5 had resolved completely. We describe these 5 patients in detail. The 5 patients were all men, mean age 68 years; their mean aneurysmal sac diameter was 54 mm. The only common finding in all of them was patency of lumbar and inferior mesenteric arteries at pre-procedure evaluation as well as at follow-up. Mean time to complete resolution was 18 months. No major complications were encountered. AAA may resolve completely after endovascular stent-graft implantation. Patent side branches may perhaps contribute to AAA disappearance by antegrade flow. A larger patient population should be reviewed, however, before any statistical conclusion can be drawn

  11. Outcomes of Endovascular Aneurysm Repair using the Ovation Stent Graft System in Adverse Anatomy.

    Science.gov (United States)

    Greaves, Nicholas S; Moore, Aiden; Seriki, Dare; Ghosh, Jonathan

    2018-04-01

    The aim was the evaluation of mid-term efficacy and safety outcome measures for the Ovation (Endologix, Santa Rosa, CA, USA) stent graft system in the management of infrarenal abdominal aortic aneurysms (iAAA) with adverse anatomy. A retrospective observational study of all patients undergoing elective iAAA repair was carried out from 2012 to 2017 using Ovation Prime or iX stent grafts with a minimum of 3 months follow-up at a single UK vascular centre. Post-operative surveillance involved computed tomography scans at 3 months and 1 year, with duplex ultrasound yearly thereafter. Outcome measures were established with retrospective analysis of pre- and post-operative imaging, and included peri-operative mortality, major adverse events, limb complications, aneurysm diameter change, and endoleak rates. All patients were within Ovation instructions for use (IFU), and assessment was made to determine whether aneurysms had anatomical features considered adverse for other commonly used stent graft platforms. Ovation stent grafts were implanted in 52 patients (79% male, mean age 75.7 years) with a mean aneurysm diameter of 62.5 mm (range 55-107 mm). There was 100% technical deployment success. The 30 day mortality was 0% and there was no aneurysm related mortality during follow-up (median 24 months, range 3-48 months). There were no type I or III endoleaks, but 19% developed type II endoleaks with one patient requiring re-intervention. No iliac limb occlusions were identified but one case required relining for limb kinking. All 52 cases were within the IFU for Ovation but only 12% met the IFU criteria for the Cook and Medtronic devices. The mid-term experience with Ovation demonstrates safe, durable treatment of iAAAs, including those with unfavourable anatomy, frequently off IFU for other commonly used devices. Copyright © 2017 European Society for Vascular Surgery. Published by Elsevier B.V. All rights reserved.

  12. Tissue Responses to Stent Grafts with Endo-Exo-Skeleton for Saccular Abdominal Aortic Aneurysms in a Canine Model

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Il Young; Chung, Jin Wook; Kim, Hyo Cheol [Dept. of Radiology and Institute of Radiation Medicine, Seoul National University College of Medicine, Clinical Research Institute, Seoul (Korea, Republic of); Choi, Young Ho; So Young Ho [Dept. of Radiology, Seoul National University Boramae Hospital, Seoul (Korea, Republic of); Kim, Hyun Beom [Dept. of Radiology, National Cancer Center, Goyang (Korea, Republic of); Min, Seung Kee [Dept. of Surgery, Seoul National University College of Medicine, Seoul (Korea, Republic of); Park, Jae Hyung [Dept. of Radiology, Gachon University Gil Medical Center, Incheon (Korea, Republic of)

    2014-10-15

    We evaluated the effect of close contact between the stent and the graft on the induction of endothelial covering on the stent graft placed over an aneurysm. Saccular abdominal aortic aneurysms were made with Dacron patch in eight dogs. The stent graft consisted of an inner stent, a expanded polytetrafluoroethylene graft, and an outer stent. After sacrificing the animals, the aortas with an embedded stent graft were excised. The aortas were inspected grossly and evaluated microscopically. The animals were sacrificed at two (n = 3), six (n = 3), and eight months (n = 2) after endovascular repair. In two dogs, the aortic lumen was occluded at two months after the placement. On gross inspection of specimens from the other six dogs with a patent aortic lumen, stent grafts placed over the normal aortic wall were covered by glossy white neointima, whereas, stent grafts placed over the aneurysmal aortic wall were covered by brownish neointima. On microscopic inspection, stent grafts placed over the normal aortic wall were covered by thin neointima (0.27 ± 0.05 mm, mean ± standard deviation) with an endothelial layer, and stent grafts placed over the aneurysmal aortic wall were covered by thick neointima (0.62 ± 0.17 mm) without any endothelial lining. Transgraft cell migration at the normal aortic wall was more active than that at the aneurysmal aortic wall. Close contact between the stent and the graft, which was achieved with stent grafts with endo-exo-skeleton, could not enhance endothelial covering on the stent graft placed over the aneurysms.

  13. Fenestrated Stent Graft Repair of Abdominal Aortic Aneurysm: Hemodynamic Analysis of the Effect of Fenestrated Stents on the Renal Arteries

    Energy Technology Data Exchange (ETDEWEB)

    Sun, Zhonghua; Chaichana, Thanapong [Curtin University of Technology, Perth (Australia)

    2010-02-15

    We wanted to investigate the hemodynamic effect of fenestrated stents on the renal arteries with using a fluid structure interaction method. Two representative patients who each had abdominal aortic aneurysm that was treated with fenestrated stent grafts were selected for the study. 3D realistic aorta models for the main artery branches and aneurysm were generated based on the multislice CT scans from two patients with different aortic geometries. The simulated fenestrated stents were designed and modelled based on the 3D intraluminal appearance, and these were placed inside the renal artery with an intra-aortic protrusion of 5.0-7.0 mm to reflect the actual patients' treatment. The stent wire thickness was simulated with a diameter of 0.4 mm and hemodynamic analysis was performed at different cardiac cycles. Our results showed that the effect of the fenestrated stent wires on the renal blood flow was minimal because the flow velocity was not significantly affected when compared to that calculated at pre-stent graft implantation, and this was despite the presence of recirculation patterns at the proximal part of the renal arteries. The wall pressure was found to be significantly decreased after fenestration, yet no significant change of the wall shear stress was noticed at post-fenestration, although the wall shear stress was shown to decrease slightly at the proximal aneurysm necks. Our analysis demonstrates that the hemodynamic effect of fenestrated renal stents on the renal arteries is insignificant. Further studies are needed to investigate the effect of different lengths of stent protrusion with variable stent thicknesses on the renal blood flow, and this is valuable for understanding the long-term outcomes of fenestrated repair.

  14. Fenestrated Stent Graft Repair of Abdominal Aortic Aneurysm: Hemodynamic Analysis of the Effect of Fenestrated Stents on the Renal Arteries

    International Nuclear Information System (INIS)

    Sun, Zhonghua; Chaichana, Thanapong

    2010-01-01

    We wanted to investigate the hemodynamic effect of fenestrated stents on the renal arteries with using a fluid structure interaction method. Two representative patients who each had abdominal aortic aneurysm that was treated with fenestrated stent grafts were selected for the study. 3D realistic aorta models for the main artery branches and aneurysm were generated based on the multislice CT scans from two patients with different aortic geometries. The simulated fenestrated stents were designed and modelled based on the 3D intraluminal appearance, and these were placed inside the renal artery with an intra-aortic protrusion of 5.0-7.0 mm to reflect the actual patients' treatment. The stent wire thickness was simulated with a diameter of 0.4 mm and hemodynamic analysis was performed at different cardiac cycles. Our results showed that the effect of the fenestrated stent wires on the renal blood flow was minimal because the flow velocity was not significantly affected when compared to that calculated at pre-stent graft implantation, and this was despite the presence of recirculation patterns at the proximal part of the renal arteries. The wall pressure was found to be significantly decreased after fenestration, yet no significant change of the wall shear stress was noticed at post-fenestration, although the wall shear stress was shown to decrease slightly at the proximal aneurysm necks. Our analysis demonstrates that the hemodynamic effect of fenestrated renal stents on the renal arteries is insignificant. Further studies are needed to investigate the effect of different lengths of stent protrusion with variable stent thicknesses on the renal blood flow, and this is valuable for understanding the long-term outcomes of fenestrated repair

  15. Aneurysmal bone cysts treated by curettage, cryotherapy and bone grafting

    NARCIS (Netherlands)

    Schreuder, HWB; Veth, RPH; Pruszczynski, M; Lemmens, JAM; Molenaar, WM; Schraffordt Koops, H.

    We treated 26 patients with 27 aneurysmal bone cysts by curettage and cryotherapy and evaluated local tumour control. complications and functional outcome. The mean follow-up time was 37 months (19 to 154), There was local recurrence in one patient. Two patients developed deep wound infections and

  16. Treatment of carotid siphon aneurysms by use of the Willis stent graft: an angiographic and histopathological study

    International Nuclear Information System (INIS)

    Zhu, Yue-Qi; Li, Ming-Hua; Xie, Jian; Tan, Hua-Qiao; Wang, Jian-Bo; Cheng, Ying-Sheng

    2010-01-01

    We designed a carotid siphon (CS) aneurysm model in dogs to test a new stent graft (the Willis covered stent) and compared tissue reaction over 12-month follow-up versus a comparison group with stents implanted in straight vessels. Twenty-four saccular sidewall aneurysms (group A) and 12 CS aneurysms (group B) were created surgically. A Willis stent graft was implanted in each aneurysm. Angiography was performed immediately and at 1-, 3-, 6- and 12-month post-implantation to investigate aneurysm isolation, endoleak, stent angulation, parent artery (PA) patency and restenosis. Light and scanning electron microscopy were used to identify aneurysmal sac thrombi, intima hyperplasia and endothelial progress. Immediate angiography demonstrated mild endoleak in two aneurysms and three stent angulations in group B. Follow-up at 12 months revealed resolved endoleaks, occlusion in one PA and mild stenosis in three in group B. In group A, occlusion occurred in one PA and mild stenosis in two. Light microscopy revealed new intima, and all aneurysm sacs were filled with thrombi. In group B, endothelial progress was complete at 12 months, and closely correlated with haemodynamic changes. Application of a Willis stent graft is a feasible method of treating CS aneurysms, and it exhibits a prolonged endothelial progress compared with that in straight vessels. (orig.)

  17. Indium-111 platelet imaging for detection of platelet deposition in abdominal aneurysms and prosthetic arterial grafts

    International Nuclear Information System (INIS)

    Ritchie, J.L.; Stratton, J.R.; Thiele, B.; Haminton, G.W.; Warrick, L.N.; Huang, T.W.; Harker, L.A.

    1981-01-01

    Thirty-four platelet imaging studies were performed in 23 patients to determine whether platelet deposition could be detected in patients with vascular aneurysms (18 patients) or in patients in whom Dacron prosthetic grafts had been placed (5 patients). In patients in whom abnormal platelet deposition was detected, the effect of administration of platelet-active drugs on platelet deposition was examined. Of the 18 patients with an aneurysm, 12 had equivocally positive studies on initial imaging and 2 had equivocally positive images. Of five patients with Dacron arterial grafts in place, four had diffuse platelet deposition in the grafts; the fifth patient had a platelet deposition only in a pseudoaneurysm. Eight patients with an abdominal aneurysm and positive or equivocally positive baseline images were restudied during platelet-active drug therapy either with aspirin plus dipyridamole (seven patients) or with sulfinpyrazone (four patients). No patient studied during treatment with aspirin plus dipyridamole had detectably decreased platelet deposition compared with baseline determinations. In contrast, two of four patients studied while receiving sulfinpyrazone showed decreased platelet deposition. Thus, platelet imaging may be of value for studying platelet physiology in vivo and for assessing platelet-active drugs and the thrombogenicity of prosthetic graft materials in human beings

  18. Aneurismas múltiplos de pontes aorto-coronárias de veia safena com ruptura fatal Multiple aneurysms of aortocoronary saphenous vein grafts with fatal rupture

    Directory of Open Access Journals (Sweden)

    Fábio R. Távora

    2007-05-01

    Full Text Available Aneurismas de pontes aorto-coronárias de veia safena são eventos raros, usualmente assintomáticos e detectados de forma incidental. Rupturas espontâneas de pontes de safena são raras, havendo poucos dados radiológicos disponíveis na literatura. Relatamos o caso de um senhor de 39 anos internado com hematêmese dez anos depois de ter sido submetido a cirurgia de revascularização miocárdica. Imagens tomográficas mostraram três aneurismas nas pontes de safena, mas o exame não detectou ruptura. O paciente veio a falecer e a necropsia revelou que a causa do óbito havia sido ruptura de aneurisma de pontes de safena. Esse caso ilustra a necessidade de tratamento agressivo de aneurismas sintomáticos de pontes coronarianas.Aortocoronary saphenous vein graft (SVG aneurysms are rare, and are usually asymptomatic and detected incidentally. Spontaneous rupture of SVG is rare and imaging data are few. We report on a 39-year old man who was admitted to the hospital with hematemesis 10 years after aortocoronary bypass surgery. CT images revealed 3 aortocoronary SVG aneurysms, but failed to detect any rupture. His subsequent death due to rupture of SVG aneurysm was documented at autopsy, illustrating the need for aggressive treatment of symptomatic coronary graft aneurysms.

  19. Pitfalls in the use of spiral CT for identification of intracranial aneurysms

    International Nuclear Information System (INIS)

    Young, N.; Kingston, R.J.; Dorsch, N.W.C.

    1999-01-01

    We describe problems encountered in our first 136 patients, with 95 aneurysms, who underwent spiral CT for investigation of possible aneurysms involving the circle of Willis and adjacent major vessels, and who had surgical and/or angiographic confirmation. There were seven false-positive cases, of which the first three could be explained by operator inexperience. There were four false negatives, all small aneurysms; two were not seen because of operator error and two were hidden by an adjacent larger aneurysm. Clip artefacts prevented diagnostic studies in six of 21 postoperative studies. One aneurysm was outside the CT field of view, being on a pericallosal artery. One basilar artery tip aneurysm was excluded from the field of the CT study because of a planning error. Inspection of the axial source images is critical if the diagnosis of small or thrombosed aneurysms is to be made. Close attention to image acquisition and computer modelling is required to reduce errors in spiral CT angiography of intracranial aneurysms. (orig.)

  20. CT finding of ruptured splenic artery aneurysm after cesarean section : a case report

    Energy Technology Data Exchange (ETDEWEB)

    Ryu, Chang Woo; Kim, Hee Jin [CHA Medical College, Pundang CHA Gerneral Hospital Sungnam, (Korea, Republic of)

    2000-03-01

    Spontaneous rupture of a splenic artery aneurysm during puerperium is rare and is due to the non-specific clinical appearance, diagnosis is difficult. We describe a case of spontaneous rupture of splenic artery aneurysm after a Cesarean section. CT showed high-density ascites localized in the lesser sac and left retroperitoneum.

  1. CT finding of ruptured splenic artery aneurysm after cesarean section : a case report

    International Nuclear Information System (INIS)

    Ryu, Chang Woo; Kim, Hee Jin

    2000-01-01

    Spontaneous rupture of a splenic artery aneurysm during puerperium is rare and is due to the non-specific clinical appearance, diagnosis is difficult. We describe a case of spontaneous rupture of splenic artery aneurysm after a Cesarean section. CT showed high-density ascites localized in the lesser sac and left retroperitoneum

  2. Evaluation of aortocoronary bypass graft patency by reconstructed CT image

    International Nuclear Information System (INIS)

    Kawakita, Seizaburo; Koide, Takashi; Saito, Yoshio; Yamamoto, Tadao; Iwasaki, Tadaaki

    1982-01-01

    Ten patients were examined in the period of three months from January to March 1981. The patients were operated from 1 month to 7 years before CT. A bypass to the left anterior descending artery (LAD) was grafted in 10 cases, 2 to the right coronary artery (RCA), 4 to an obtuse marginal artery (OM), and 1 to a diagonal artery. Image reconstruction was performed in 10 cases by using an image analytical computer Evaluskop. Appropriate planes for reconstruction were selected by trial and error methods upon observation of CT images. When gained picture of a graft course coincided with surgical records or angiography, the work of building images was concluded. On cross section, grafts to LAD were visualized in all 10 cases: 9 in the entire course and 1 in a proximal part of the graft. Two to RCA, 4 to OM and 1 to a diagonal were also successfully visualized. Reconstruction of graft images succeeded in 9 grafts of 6 cases. The course of a graft could be pursued from the proximal to the distal end adjacent to the cardiac chamber. The picture of a bypass to LAD was visualized in 6 of 10 grafts. Two bypass to RCA could be depicted, and 1 to OM was also found. However 3 to OM and 1 to a diagonal failed to be visualized throughout their courses in reconstructed images. I think that the causes of faillure mainly depended upon the course of the graft. When a graft was running arc-like surrounding the heart chamber, it was very difficult to depict its entire length in reconstructed images, though the graft could be detected in cross sections. These preliminary studies indicated that reconstruction of CT images had some benefits for the pursuit of graft courses. (J.P.N.)

  3. Treatment of complex internal carotid artery aneurysms using radial artery grafts. Surgical technique, perioperative complications, and results in 17 patients

    International Nuclear Information System (INIS)

    Murai, Yasuo; Teramoto, Akira; Mizunari, Takayuki; Kobayashi, Shiro; Kamiyama, Hiroyasu

    2007-01-01

    Complex giant or large internal carotid artery aneurysms present a surgical challenge because limitations and difficulty are encountered with either clipping or endovascular treatment. Our review of previous reports suggests that no current vascular assessment can accurately predict the occurrence of ischemic complications after internal carotid artery ligation. The present study concerns surgical technique, complications, and clinical outcome of radial artery grafting followed by parent artery trapping or proximal occlusion for management of these difficult lesions. Between September 1997 and October 2005, we performed radial artery grafting followed immediately by parent artery occlusion in 17 patients with giant or large complex intracranial carotid aneurysms (3 men, 14 women; mean follow-up duration, 62 months). All patients underwent postoperative digital subtraction angiography to assess graft patency and aneurysm obliteration. All 17 aneurysms were excluded from the cerebral circulation, with all radial artery grafts patent. Among 4 patients with cranial nerve disturbances, dysfunction was temporary in 5; in the others, oculomotor nerve paresis persisted. No perioperative cerebral infarction occurred. Sensory aphasia reflecting cerebral contusions caused by temporal lobe retraction resolved within 2 months, as did hemiparesis from a postoperative epidural hematoma. With appropriate attention to surgical technique, radial artery grafting followed by acute parent artery occlusion is a safe treatment for complex internal carotid artery aneurysms. Graft patency and aneurysm thrombosis were achieved in all patients. Cranial nerve dysfunction (III, VI) caused by altered blood flow from the internal carotid artery after occlusion was the most common complication and typically was temporary. In our experience with these difficult aneurysms, not only clipping but also reconstruction of the internal carotid artery was required, especially for wide-necked symptomatic

  4. CT during selective arteriography: anatomical assessment of unruptured intracranial aneurysms before endovascular treatment

    International Nuclear Information System (INIS)

    Nomura, M.; Kida, S.; Uchiyama, N.; Yamashima, T.; Yamashita, J.; Sanada, J.; Yoshikawa, J.; Matsui, O.

    2001-01-01

    Our aim was to investigate the usefulness of helical CT during selective angiography (CT arteriography) in pretreatment assessment of unruptured intracranial aneurysms. We studied 47 unruptured aneurysms in 34 prospectively recruited patients for whom endovascular embolisation was initially considered. As pretreatment assessment, we performed rotational digital subtraction angiography (DSA) followed by CT arteriography. The findings on axial source images (axial images) and reconstructed three-dimensional CT angiography (3D-CTA) of CT arteriography were compared to those of rotational DSA, with particular attention to the neck of the aneurysm and arterial branches adjacent to it. Information provided by CT arteriography was more useful than that of rotational DSA as regards the neck in 25 (53 %) of 47 cases and as regards branches in 18 (49 %) of 37 aneurysms. On axial images, small arteries such as the anterior choroidal artery were seen in some cases. CT arteriography can provide valuable additional information about unruptured aneurysms, which cannot be obtained by rotational DSA alone. This technique is useful for obtaining anatomical information about aneurysm anatomy and for deciding the therapeutic strategy. (orig.)

  5. Chronologic changes of free fat graft in rabbit using CT

    International Nuclear Information System (INIS)

    Kondo, Norihiro; Kurita, Kenichi; Yajima, Tetsuya; Izumi, Masahiro

    2008-01-01

    Free fat grafts are now used for preventing osteal readhesion, filling dead space, and protecting grafted nerves and vessels. However, it is reported that grafted fat tissue is unstable resulting in high risk of cicatrization and infection. We grafted free fat to a rabbit's back and observed the chronologic change using CT. Ten adult male Japanese white rabbits (3.5 kg) were used. In five rabbits, fat tissue was obtained from the back under general anaesthesia, and transplanted into the back about 50 mm posterior from the donor site. CT was taken in the fixed scan condition five times (preoperation, immediate postoperation, postoperative 1-month, 2-month, and 3-month). In the remaining five rabbits, only CT scan was taken three times as a control. It was observed that we compared preoperative fat volume with the postoperative volume using RealINTAGE. Grafted fat tissue decreased postoperatively at 1-month and completely disappeared at 3-months. We were able to prove that CT scan is effective to observe the chronologic change of grafted fat tissue. Techniques of tissue engineering are necessary for survival of grafted fat tissue. (author)

  6. Late Complication after Superficial Femoral Artery (SFA) Aneurysm: Stent-graft Expulsion Outside the Skin

    Energy Technology Data Exchange (ETDEWEB)

    Pecoraro, Felice, E-mail: felicepecoraro@libero.it; Sabatino, Ermanno R.; Dinoto, Ettore; Rosa, Giuliana La; Corte, Giuseppe; Bajardi, Guido [University of Palermo, Vascular Surgery Unit (Italy)

    2015-10-15

    A 78-year-old man presented with a 7-cm aneurysm in the left superficial femoral artery, which was considered unfit and anatomically unsuitable for conventional open surgery for multiple comorbidities. The patient was treated with stent-graft [Viabhan stent-graft (WL Gore and Associates, Flagstaff, AZ)]. Two years from stent-graft implantation, the patient presented a purulent secretion and a spontaneous external expulsion through a fistulous channel. No claudication symptoms or hemorrhagic signs were present. The pus and device cultures were positive for Staphylococcus aureus sensitive to piperacillin/tazobactam. Patient management consisted of fistula drainage, systemic antibiotic therapy, and daily wound dressing. At 1-month follow-up, the wound was closed. To our knowledge, this is the first case of this type of stent-graft complication presenting with external expulsion.

  7. Development of an abdominal aortic aneurysm model for stent-graft insertion

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Tae Hyung; Lee, Jong Heon; Shin, Dong Ik; Sung, Kyu Bo; Ko, Gi Young; Lim, Jin Oh [College of Medicine, Univ. of Ulsan, Seoul (Korea, Republic of); Kim, Si Hoon [S and G Biotech Research Institute, Seoul (Korea, Republic of)

    2002-03-01

    To determine the efficacy of an abdominal aortic aneurysm model for stent-graft placement. The model consists of two parts, the heart and the vascular system. A peristaltic pump and a solenoid valve were used to simulate a pulsatile flow from the heart. A ball-shaped piece of clay was placed inside a square box and liquid silicone was poured. After the silicone was formed, the clay was removed and a silicone tube was used to connect the heart model and the aneurysm model. The silicone tube was also used to simulate the iliac arteries and one end of the artery was clampled and the other one was extended to water bath. Water at 37 .deg. C was circulated through the model, and the pressure at the thoracic aorta, aneurysm and iliac artery was measured with the outlet valve opening at 25, 50, and 100% before and after stent-graft placement. The liquid pressure measurements were 253/252, 271/162 and 264/166 mmHg at the thoracic aorta, aneurysm and iliac artery, respectively, when the outlet was 100% open. They were 173/121, 145/99, 145/106 mmHg when the outlet was 50% open, and 35/28, 61/44, 24/22 mmHg when it was 25% open. After placement of the stent-graft, the pressure measurements were 170/128, and 167/128 mmHg, respectively. Since it was easy to produce, the model was useful for in-vitro stent-graft testing, and a wide range of pressure could be applied.

  8. Concepts to optimize stent-grafting of abdominal aortic aneurysms based on results of experimental studies

    International Nuclear Information System (INIS)

    Chavan, A.; Kirchhoff, T.; Baus, S.; Galanski, M.; Pichlmaier, M.

    2001-01-01

    Purpose. In the endoluminal therapy of abdominal aortic aneurysms, a short proximal aneurysm neck, endoleaks and the large size and stiffness of the introducer systems are responsible for many of the complications and sub-optimal outcomes. The purpose of the present review article is to to suggest strategies to minimize these complications based on the results of experimental studies in animals. Material and methods. After implanting various types of stents across the renal artery origins, the functional and morphological changes in the kidneys and renal vessels were studied by various authors. In order to prevent progressive widening of the proximal aneurysmal neck and graft dislocation, Sonesson et al. performed a laparoscopic banding around the proximal neck in pigs. To study the effects of endoleaks, Marty, Schurink and Pitton carried out pressure measurements in experimental aneurysms with and without endoleaks. Sakaguchi and Pavcnik developed the 'Twin-tube endografts' (TTEG) and the 'Bifurcated drum occluder endografts' (BDOEG) and tested them in dogs. Results. Up to 3 months after suprarenal stent placement, Chavan et al. detected no significant fall in the mean inulin clearance in sheep (140±46 ml/min before, 137±58 ml/min after). Nasim et al. and Malina et al. reported similar observations with respect to renal function. Suprarenal fixation may result in isolated thrombotic occlusions of the renal arteries and microinfarcts in the kidneys. Mean aortic diameters at the level of banding were significantly smaller in the animals with aortic banding as opposed to those in the control group without banding (8 mm vs 11 mm, p=0.004). The banding caused a secure proximal fixation of the stent-graft. Persistent endoleaks resulted in significantly higher intraaneurysmal pressures. Although the TTEG and the BDOEG stent-grafts required smaller sheaths, occlusions were observed in 8% (TTEG) and 60% (BDOEG) of the graft limbs. (orig.) [de

  9. Preoperative cerebral aneurysm assessment by three-dimensional CT angiography. Feasibility of surgery without cerebral angiography

    International Nuclear Information System (INIS)

    Kashiwagi, Shiro; Yamashita, Katsuhiro; Kato, Shoichi; Ito, Haruhide; Kurokawa, Kensuke; Watanabe, Yutaka

    1999-01-01

    The purpose of this study is to assess the capability of three-dimensional CT angiography (3D-CTA) to replace conventional catheter angiography as a preoperative examination for unruptured intracranial aneurysms. A prospective study was designed to evaluate 18 patients with 20 unruptured intracranial aneurysms (13 middle cerebral artery aneurysms, 6 anterior communicating artery aneurysms, and 1 internal carotid posterior communicating artery aneurysm) who underwent surgery. There were 12 women and 6 men with the average age of 63 years old. All patients were initially diagnosed as having intracranial aneurysms by MR angiography, followed by 3D-CTA and conventional catheter angiography for confirmation. Three experienced neurosurgeons were in charge of the operations. One of the neurosurgeons (surgeon 1) was provided with only 3D-CTA as the preoperative radiological evaluation, while the others (surgeon 2 and 3) were given through assessments with MRA, 3D-CTA, and conventional angiography. Surgeon 1 carried out the operations under careful observation by the surgeons 2 and 3. Problems encountered by the surgeon 1 during surgery were recorded. Neck clipping in 19 aneurysms and dome wrapping in 1 were successfully accomplished. All patients were discharged without complication. Surgeries went smoothly in 16 aneurysms with 3D-CTA alone. Discrepancies between the 3D-CTA findings and microsurgical anatomy were noted in 4 aneurysms: the size of the neck was overestimated in 3 aneurysms, the relationships to parent arteries were obscure in 2 aneurysms, and a perforating artery problematic to neck clipping was missed in 1 aneurysms by 3D-CTA. The results of this study support the notion that 3D-CTA can replace conventional catheter angiography as preoperative examination in the majority of regular-sized anterior circulation aneurysms. Nevertheless, surgeons should recognize and be prepared for the fact that 3D-CTA can give false impression about the aneurysm neck and

  10. A 10-year institutional experience with open branched graft reconstruction of aortic aneurysms in connective tissue disorders versus degenerative disease.

    Science.gov (United States)

    Hicks, Caitlin W; Lue, Jennifer; Glebova, Natalia O; Ehlert, Bryan A; Black, James H

    2017-11-01

    Aortic reconstruction for complex thoracoabdominal aortic aneurysms (TAAAs) can be challenging, especially in patients with connective tissue disorders (CTDs) in whom tissue fragility is a major concern. Branched graft reconstruction is a more complex operation compared with inclusion patch repair of the aorta but is frequently necessary in patients with CTDs or other pathologies because of anatomic reasons. We describe our institutional experience with open branched graft reconstruction of aortic aneurysms and compare outcomes for patients with CTDs vs degenerative pathologies. We retrospectively analyzed all patients undergoing open aortic reconstruction using branched grafts at our institution between July 2006 and December 2015. Postoperative outcomes, including perioperative morbidity and mortality, midterm graft patency, and the development of new aneurysms, were compared for patients with CTD vs degenerative disease. During the 10-year study period, 137 patients (CTD, 29; degenerative, 108) underwent aortic repair with branched graft reconstruction. CTD patients were significantly younger (39 ± 1.9 vs 68 ± 1.0 years; P disease, coronary artery disease; P degenerative disease. Perioperative mortality (CTD: 10% [n = 3] vs degenerative: 6% [n = 6]; P = .40) and any complication (62% vs 55%; P = .47) were similar between groups. At a median follow-up time of 14.5 months (interquartile range: 6.5, 43.9 months), CTD patients were more likely to develop both new aortic (21%) and nonaortic (14%) aneurysms compared with the degenerative group (7% and 4% for aortic and nonaortic aneurysms, respectively; P = .02). Loss of branch graft patency occurred in 0 of 99 grafts (0%) in CTD patients and in 13 of 167 grafts (7.8%) in degenerative disease patients (P = .005). Loss of branch graft patency occurred most commonly in left renal artery bypass grafts (77%) and was clinically asymptomatic (creatinine: 1.77 ± 0.13 mg/dL currently vs 1.41 ± 0

  11. Evaluation of CT virtual intravascular endoscopy in fenestrated stent grafts: a preliminary study

    International Nuclear Information System (INIS)

    Sun, Z.; Allen, Y.; Fitzsimmons, B.; Hartely, D.; Lawrence-Brown, M.

    2007-01-01

    We aim in this study to investigate the potential value of CT virtual intravascular endoscopy in patients diagnosed with abdominal aortic aneurysms undergoing fenestrated stent grafts. Both pre-and post-fenestration (within 3 months of implantation) multislice CT data were collected in eight patients and used for generation of virtual endoscopy images in our preliminary study. Variable fenestrations were deployed in 25 aortic branches with scallop fenestration implanted in six aortic ostia, large fenestration in four aortic ostia and small fenestration in 15 renal ostia, respectively. Measurements of the aortic ostia diameters both pre- and post-fenestration were successfully performed with virtual intravascular endoscopy visualization, and endovascular stents as well as their relationship to the aortic ostia were clearly demonstrated. Our results showed that there was no significant change of diameter of the aortic ostia following fenestrated stem grafts. Endovascular stents were clearly visualized on virtual endoscopy images, and no apparent deformity or malrotation was observed in this small group. Our preliminary study provides new insights into anatomic configuration/dimension of aortic ostia and endovascular stents, and virtual intravascular endoscopy could be a valuable technique to follow-up patients treated with fenestrated stent grafts. (orig.)

  12. Evaluation of CT virtual intravascular endoscopy in fenestrated stent grafts: a preliminary study

    Energy Technology Data Exchange (ETDEWEB)

    Sun, Z. [Dept. of Imaging and Applied Physics, Curtin Univ. of Tech., Perth, WA (Australia); Allen, Y.; Fitzsimmons, B.; Hartely, D. [Cook R and D, WA (Australia); Lawrence-Brown, M. [Dept. of Public Health, Curtin Univ. of Tech., Perth, WA (Australia)

    2007-06-15

    We aim in this study to investigate the potential value of CT virtual intravascular endoscopy in patients diagnosed with abdominal aortic aneurysms undergoing fenestrated stent grafts. Both pre-and post-fenestration (within 3 months of implantation) multislice CT data were collected in eight patients and used for generation of virtual endoscopy images in our preliminary study. Variable fenestrations were deployed in 25 aortic branches with scallop fenestration implanted in six aortic ostia, large fenestration in four aortic ostia and small fenestration in 15 renal ostia, respectively. Measurements of the aortic ostia diameters both pre- and post-fenestration were successfully performed with virtual intravascular endoscopy visualization, and endovascular stents as well as their relationship to the aortic ostia were clearly demonstrated. Our results showed that there was no significant change of diameter of the aortic ostia following fenestrated stem grafts. Endovascular stents were clearly visualized on virtual endoscopy images, and no apparent deformity or malrotation was observed in this small group. Our preliminary study provides new insights into anatomic configuration/dimension of aortic ostia and endovascular stents, and virtual intravascular endoscopy could be a valuable technique to follow-up patients treated with fenestrated stent grafts. (orig.)

  13. Cine CT in the evaluation of coronary bypass graft patency

    International Nuclear Information System (INIS)

    Stanford, W.; Rooholamini, M.; Rumberger, J.; Marcus, M.; Hiratzka, L.

    1986-01-01

    Cine CT produces axial images over an 8-cm section of the aorta in 50 msec. This characteristic makes the technique useful for evaluating coronary bypass graft (CBG) patency. With the use of 40 ml of 67% iothalamate sodium injected via an antecubital vein, 28 patients with 68 CBGs underwent cine CT. Ten patients with 21 CBGs also underwent cardiac catheterization. In the latter group the overall accuracy of cine CT compared to cardiac catheterization was 95.2% (20/21). The sensitivity was 94.1% (16/17), and the specificity was 100% (4/4). This figure compares favorably with the 92% sensitivity achieved with conventional CT

  14. Three dimensional CT angiography (3D-CTA) in ruptured aneurysm surgery on acute stage

    International Nuclear Information System (INIS)

    Matsumoto, Masato; Endo, Yuji; Nakano, Masayuki

    1998-01-01

    We evaluated three-dimensional CT angiography (3D-CTA) for the treatment of acutely ruptured cerebral aneurysms. Sixty patients with subarachnoid hemorrhage from cerebral aneurysms were investigated both by 3D-CTA and conventional angiography and 26 patients were studied using 3D-CTA without conventional angiography. In the 60 cases, both 3D-CTA and the conventional angiography revealed 100% accuracy in diagnosing ruptured aneurysms, and 3D-CTA and the conventional angiography showed 96% and 92% accuracy for unruptured aneurysms respectively. 3D-CTA was equal or superior to the conventional angiography. Based on these data, since December, 1996, we have operated on 26 consecutive patients with ruptured aneurysms located in the anterior circulation of the circle of Willis, using 3D-CTA without conventional angiography. Thirty-one aneurysms, including 5 associated unruptured aneurysms, were visualized by 3D-CTA and verified at surgery. All aneurysms were clipped successfully. We think that it will be possible to operate on most ruptured aneurysms using only 3D-CTA without the conventional angiography except for the cases of the following situations: if a cerebral infarction is present, conventional angiography is required to evaluate for a stenotic or occlusive lesion of the intracranial arteries, cervical carotid, or vertebral arteries; in cases of giant or large aneurysms, the dynamic information provided by the conventional angiography is needed in case bypass surgery is necessary; and for aneurysms close to bony structures, such as an internal carotid-ophthalmic artery aneurysm, conventional angiography is necessary. (author)

  15. Detection of aneurysms in subarachnoidal hemorrhage - CT-angiography versus digital subtraction angiography

    International Nuclear Information System (INIS)

    Roehnert, W.; Haenig, V.; Hietschold, V.; Abolmaali, N.

    1998-01-01

    Purpose: The value of CT-angiography (CT-A) for the visualization of intracranial aneurysms was more closely defined by comparison with digital subtraction angiography (DSA). Methods: Over a period of 18 months a total of 106 patients in whom a subarachnoidal hemorrhage had been detected on native CT were examined in parallel by spiral CT and DSA. CT-angiography was performed under standardized parameters and included processing with 3D surface reconstructions. Results: In 64 patients (60.4%) at total of 72 aneurysms were detected. In four cases (6.2%) there were two and in two cases (3.1%) even three aneurysms. The findings of DSA and CTA agreed in 98 cases (92.5%). In four patients (3.8%) a false negative results was obtained in CTA and the initial DSA. Conclusions: Digital subtraction angiography must still be considered as the gold standard in the diagnosis of cerebral aneurysms. On account of its excellent spatial delineation of aneurysms and possibilities for exact measurements, CT-angiography represents a valuable, supplementary method - in some cases also an alternative method - to digital subtraction angiography. (orig.) [de

  16. Growth-mechanism of giant intracranial aneurysms; demonstration by CT and MR imaging

    Energy Technology Data Exchange (ETDEWEB)

    Schubiger, O.; Valavanis, A.; Wichmann, W.

    1987-05-01

    In four cases of giant intracranial aneurysm, CT demonstrated a hyperdense open-, or closed-ring structure at the periphery of the aneurysm. Surgery in two of the cases demonstrated that this peripheral hyperdensity represents fresh clot inside the wall of the thrombosed mass. An analogy is established between giant intracranial aneurysms, chronic subdural hematomas and growing encapsulated intracerebral hematomas. The common feature of the three entities is slow growth by recurrent hemorrhages into the lesion. It is proven that growth of chronic subdural hematomas and of growing encapsulated hematomas is related to recurrent hemorrhage from capillaries sprouting within the membrane of the lesion. The highly vascularized membranous wall of a giant intracranial aneurysm seems to behave like the membrane of a chronic subdural hematoma. It is suggested that the giant intracranial aneurysm grows by recurrent hemorrhage into its wall and behaves like growing encapsulated hematomas.

  17. Preoperative evaluation of the abdominal aortic aneurysm using spiral CT

    International Nuclear Information System (INIS)

    Chisuwa, Hisanao; Nishimaki, Keiji; Arai, Masayuki; Honda, Haruyasu; Urata, Koichi; Miyagawa, Yusuke; Makuuchi, Masatoshi; Shimizu, Mikio; Okamoto, Kohei.

    1995-01-01

    Six patients with abdominal aortic aneurysm (AAA) were studied with three-dimensionally reconstructed CT angiography (3D-CTA) in order to evaluate its usefulness as a diagnostic tool for vascular surgery patients. Images of the intravenously contrasted abdominal aorta were obtained with spiral scan during a single breath hold. The images of the abdominal aorta and its major branches were three-dimensionally reconstructed with a shaded surface display mode. The three-dimensional image reconstruction was successful in all the six cases and performed without difficulties. Shaded surface display presented a deficit to depict the aortic wall with mural thrombus. However, multidirectional display of the abdominal aorta and its branches facilitated interpretation of the anatomical details of the lesions and planning of surgical repair. 3D-CTA is an alternative to conventional aortography for preoperative diagnosis of AAA. Moreover it was shown to be noninvasive, easy to proceed. It presented good angiographical resolution that can be used as a precise diagnostic tool in vascular surgery. (author)

  18. Treatment of carotid-siphon aneurysms by using willis stent-graft: an angiographic and histopathologic study in dogs

    International Nuclear Information System (INIS)

    Zhu Yueqi; Li Minghua; Xie Jian; Tan Huaqiao; Cheng Yingsheng; Wang Jianbo

    2010-01-01

    Objective: To establish a carotid siphon aneurysm model in dogs in order to test the mechanical features of a newly-designed Willis covered stent-graft and to investigate the histological reaction of the stent-implanted vessel during a follow-up period of 12 months. Methods: Twenty-four saccular sidewall aneurysms were surgically created in twelve dogs (group A) and 12 carotid siphon aneurysms in another twelve dogs (group B). A Willis stent-graft was implanted in each aneurysm. Angiography was performed immediately after the procedure and 1, 3, 6 and 12 months after the implantation to investigate the aneurysm isolation, endoleak, stent angulation, and the patency or restenosis of the parent artery. Light and scanning electronic microscopy were used to identify aneurysmal sac thrombi, intima hyperplasia and endothelial progress of the stent-loaded arterial segment. Results: In group B, postoperative immediate angiography demonstrated that two aneurysms had mild endoleak and three stents became angulated. Follow-up exam 12 months after the procedure revealed that all previous endoleaks disappeared, one parent artery became occluded and three parent arteries developed mild stenosis (< 50%). In group A, occlusion of parent artery was seen in one and mild stenosis (< 50%) in 2 cases. Electronic microscopy revealed new intima formation in all stents, and all aneurysmal sacs were filled with thrombi. In group B, the endothelialization process was not completed until 12 months after the stent implantation, and a marked correlation existed between endothelial cell arrangement and the hemodynamic orientation. Conclusion: It is feasible to treat carotid-siphon aneurysm in dog with a Willis stent-graft. The complete endothelialization of the covered stent in tortuous vessel takes longer time than that in rather straight vessel. (authors)

  19. Multilevel segmentation of intracranial aneurysms in CT angiography images

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Yan [Radiology and Biomedical Imaging, University of California, San Francisco, San Francisco, California 94122 and University of Lyon, CREATIS, CNRS UMR 5220, INSERM U1206, UCB Lyon1, INSA Lyon, Lyon 69100 (France); Zhang, Yue, E-mail: y.zhang525@gmail.com [Veterans Affairs Medical Center, San Francisco, California 94121 and University of Lyon, CREATIS, CNRS UMR 5220, INSERM U1206, UCB Lyon1, INSA Lyon, Lyon 69100 (France); Navarro, Laurent [Ecole Nationale Superieure des Mines de Saint-Etienne, Saint-Etienne 42015 (France); Eker, Omer Faruk [CHU Montpellier, Neuroradiologie, Montpellier 34000 (France); Corredor Jerez, Ricardo A. [Ecole Polytechnique Federale de Lausanne, Lausanne 1015 (Switzerland); Chen, Yu; Zhu, Yuemin; Courbebaisse, Guy [University of Lyon, CREATIS, CNRS UMR 5220, INSERM U1206, UCB Lyon1, INSA Lyon, Lyon 69100 (France)

    2016-04-15

    Purpose: Segmentation of aneurysms plays an important role in interventional planning. Yet, the segmentation of both the lumen and the thrombus of an intracranial aneurysm in computed tomography angiography (CTA) remains a challenge. This paper proposes a multilevel segmentation methodology for efficiently segmenting intracranial aneurysms in CTA images. Methods: The proposed methodology first uses the lattice Boltzmann method (LBM) to extract the lumen part directly from the original image. Then, the LBM is applied again on an intermediate image whose lumen part is filled by the mean gray-level value outside the lumen, to yield an image region containing part of the aneurysm boundary. After that, an expanding disk is introduced to estimate the complete contour of the aneurysm. Finally, the contour detected is used as the initial contour of the level set with ellipse to refine the aneurysm. Results: The results obtained on 11 patients from different hospitals showed that the proposed segmentation was comparable with manual segmentation, and that quantitatively, the average segmentation matching factor (SMF) reached 86.99%, demonstrating good segmentation accuracy. Chan–Vese method, Sen’s model, and Luca’s model were used to compare the proposed method and their average SMF values were 39.98%, 40.76%, and 77.11%, respectively. Conclusions: The authors have presented a multilevel segmentation method based on the LBM and level set with ellipse for accurate segmentation of intracranial aneurysms. Compared to three existing methods, for all eleven patients, the proposed method can successfully segment the lumen with the highest SMF values for nine patients and second highest SMF values for the two. It also segments the entire aneurysm with the highest SMF values for ten patients and second highest SMF value for the one. This makes it potential for clinical assessment of the volume and aspect ratio of the intracranial aneurysms.

  20. [Giant aneurysm of posterior comunicating artery (PCoA) in cerebral panarteriography and CT angiography (CTA)].

    Science.gov (United States)

    Jaźwiec, Przemysław; Chwiszczuk, Luiza; Sasiadek, Marek; Całka, Karol; Kuniej, Tomasz; Plucińska, Irena

    2008-01-01

    We present a case of 32-year-old woman, who was admitted to the Department of Neurology in the emergency mode, due to: instantaneous pupillary dilation (mydriasis), ptosis of the left eyeball and double vision. We performed plain CT, panarteriography of cerebral vessels, CT angiography with RT3D (volume-rendered three-dimensional) reconstruction images. On the base of imaging studies the diagnosis of giant saccular aneurysm of the left posterior communicating artery was established. The patient was operated on and the giant aneurysm of left posterior communicating artery was clipped, confirming radiological diagnosis. During operation and postoperative period no complications were noted.

  1. Treatment of a Common Iliac Aneurysm by Endovascular Exclusion Using the Amplatzer Vascular Plug and Femorofemoral Crossover Graft

    International Nuclear Information System (INIS)

    Coupe, Nicholas J.; Ling, Lynn; Cowling, Mark G.; Asquith, John R.; Hopkinson, Gregory B.

    2009-01-01

    We report our initial experience using the Amplatzer Vascular Plug II (AVP2) in the treatment of a left common iliac aneurysm. Following investigation by computerized tomographic angiography and catheter angiography, a 79-year-old man was found to have a markedly tortuous iliac system, with a left common iliac artery aneurysm that measured 48 mm in maximal diameter. Due to the patient's age and comorbidities the surgical opinion was that conventional open repair was not suitable. However, due to the tortuous nature of the aneurysm and iliac vessels, standard endovascular repair, using either a bifurcated or an aorto-uni-iliac stent graft, was also not possible. A combined approach was used by embolizing the ipsilateral internal iliac artery using coils and excluding the aneurysm using two AVP2 occlusion devices, followed by femorofemoral crossover grafting. Total aneurysm occlusion was achieved using this method and this allowed the patient to have a much less invasive surgical procedure than with conventional open repair of common iliac aneurysms, thus avoiding potential comorbidity and mortality.

  2. Anatomic differences of the distal aorta with dilatation or aneurysm between patients from Asia and Europe as seen on CT imaging

    Energy Technology Data Exchange (ETDEWEB)

    Mladenovic, Ana S., E-mail: ancicak@yahoo.com [Institute of Radilogy, Clinical Centre of Serbia, Visegradska 26, DP 237, 11 000 Belgrade (Serbia); Markovic, Zeljko Z., E-mail: dr.zmarkovic@gmail.com [Clinical Center of Serbia, Center of Radiology, Belgrade (Serbia); Institute of Radilogy, Clinical Centre of Serbia, Visegradska 26, DP 237, 11 000 Belgrade (Serbia); Hyodoh, Hideki H., E-mail: hyodoh@sapmed.ac.jp [Department of Radiology, Sapporo Medical University, S1W17, Chuo-ku, Sapporo 060-8556 (Japan)

    2012-09-15

    Aim: The hypothesis of this research is that there are differences in morphology of dilated and aneurysm changed infrarenal aorta between the patients from Europe and Asia that are important for endovascular treatment. Authors analyzed the morphologic differences of the infra-renal segment of abdominal aorta (a.a.) and the iliac arteries, common iliac artery (c.i.a.) between the Asians and Europeans examined by computed tomography (64 MD CT) from the point of the clinical use of the endovascular stent-graft. Materials and methods: The research was conducted simultaneously in Europe and in Asia and 60 patients with distal aorta aneurysm were included (30 of each ethnic origin). The examinations were conducted at the identical types of 64 MD CT equipment, and under same conditions of examination technique and post-processing. Results: There were statistically significant differences in regard to important morphology criteria for a.a. and c.i.a. between patients with the aneurysm from Asia and the Europe. Analysis was preformed referring to the gender, age, body weight (BW), height, body mass index (BMI), body surface (SA index), and various diameters of a.a. and c.i.a. at several linear and transversal levels, angle and volume of the aneurysm. The biggest differences relate to the width of the central part of aneurysm of a.a. and the length and volume of c.i.a. Conclusion: There were statistically significant differences in regard to important morphology criteria for a.a. and c.i.a. between patients with the aneurysm from Asia and the Europe.

  3. Likelihood of aneurysmal subarachnoid haemorrhage in patients with normal unenhanced CT, CSF xanthochromia on spectrophotometry and negative CT angiography.

    Science.gov (United States)

    Rana, A K; Turner, H E; Deans, K A

    2013-01-01

    Patients with suspected subarachnoid haemorrhage, a normal noncontrast computed tomography (CT) and cerebrospinal fluid (CSF) evidence of haemoglobin breakdown products often undergo CT angiography (CTA). If this is normal, then invasive catheter angiography may be offered. In current clinical practice, haemoglobin breakdown products are detected by spectrophotometry rather than visible xanthochromia, and CTA is performed on multidetector scanners. The aim of this study was to determine if such patients should still have a catheter angiography, given the associated risks. Patients positive for CSF spectrophotometry (n=26) were retrospectively identified from the clinical biochemistry information system and imaging data from the electronic radiology records were reviewed. Discharge letters were consulted to relate the biochemistry and radiology results to the final diagnosis. 15 patients with CT angiography were found. Nine patients had normal CT angiography. No causative aneurysms had been missed. One patient had small, coincidental aneurysms missed on initial reading of the CTA. The likelihood of a clinically significant aneurysm in a patient who is CT negative, lumbar puncture positive and CTA negative is low. Double reporting of negative CT angiograms may be advisable.

  4. Multislice CT imaging of ruptured left sinus of Valsalva aneurysm with fistulous track between left sinus and right atrium.

    Science.gov (United States)

    Pampapati, Praveenkumar; Rao, Hejmadi Tati Gururaj; Radhesh, Srinivasan; Anand, Hejjaji Krishnamurthy; Praveen, Lokkur Srinivasamurthy

    2011-01-01

    Sinus of valsalva aneurysm is a rare condition arising from any of the three aortic sinuses. Among them, an aneurysm arising from the left coronary sinus is the rarest. Most of these cases were earlier diagnosed using echocardiography and conventional angiography. But with the availability of advanced imaging modalities like 64 slice cardiac CT and MR modalities, this condition can be accurately assessed noninvasively. We report a case of ruptured aneurysm originating from the left coronary sinus with a long windsock type of fistulous track between the aneurysm and right atrium evaluated by 64 slice cardiac CT imaging. This was later confirmed perioperatively.

  5. Immediate CT findings following embolization of cerebral aneurysms: suggestion of blood-brain barrier or vascular permeability change

    International Nuclear Information System (INIS)

    Baik, Seung Kug; Kim, Yong Sun; Lee, Hui Jung; Kim, Gab Chul; Park, Jaechan

    2008-01-01

    Although endovascular techniques are widely used for the treatment of cerebral aneurysms, the immediate postprocedural brain CT findings have not been reported. Therefore, in the present study we assessed the immediate postprocedural brain CT findings following the uneventful coil embolization of cerebral aneurysms. Included in the study were 59 patients with 61 cerebral aneurysms after uncomplicated coil embolization. Acute subarachnoid hemorrhage was present with 32 of the 61 aneurysms. All patients underwent a brain CT scan just before and within 2 h after the endovascular treatment. If the postprocedural CT scan revealed any new findings, a follow-up CT scan and/or MRI were performed within 24 h. The variables related to the abnormal CT findings were also evaluated. Among the 61 immediate brain CT scans, 26 (43%) showed abnormal findings, including cortical contrast enhancement (n=21, 34%), subarachnoid contrast enhancement (n=8, 13%), intraventricular contrast enhancement (n=5, 8%), and striatal contrast enhancement (n=2, 3%). Single or mixed CT findings were also seen. None of the 61 aneurysms was associated with new neurological symptoms after endovascular treatment, and all patients made an uneventful recovery. Abnormal findings were more likely to be found with lower body weight and with increased corrected amounts of contrast material and heparin (P<0.05). After uneventful endovascular treatment of cerebral aneurysms, the immediate brain CT findings can reveal various patterns of abnormal contrast enhancement. Recognizing the immediate brain CT findings is important, as they can mimic various diseases. (orig.)

  6. 18F-FDG PET-CT uptake is a feature of both normal diameter and aneurysmal aortic wall and is not related to aneurysm size

    International Nuclear Information System (INIS)

    Barwick, Tara D.; Lyons, O.T.A.; Waltham, M.; Mikhaeel, N.G.; O'Doherty, M.J.

    2014-01-01

    Aortic metabolic activity is suggested to correlate with presence and progression of aneurysmal disease, but has been inadequately studied. This study investigates the 2-[ 18 F] fluoro-2-deoxy-D-glucose ( 18 F-FDG) uptake in a population of infra-renal abdominal aortic aneurysms (AAA), compared to a matched non-aneurysmal control group. The Positron Emission Tomography - Computed Tomography (PET/CT) database was searched for infra-renal AAA. Exclusion criteria were prior repair, vasculitis, and saccular/mycotic thoracic or thoraco-abdominal aneurysms. Matching of 159 non-aneurysmal ( max ) and target to background mediastinal blood pool ratio (TBR) were documented. Predictors of FDG uptake (age, sex, aortic diameter, hypertension, statin use, and diabetes) were assessed using univariate analysis. Follow-up questionnaires were sent to referring clinicians. Aneurysms (n = 151) and controls (n = 159) were matched (p > 0.05) for age, sex, diabetes, hypertension, smoking status, statin use, and indication for PET/CT. Median aneurysm diameter was 5.0 cm (range 3.2-10.4). On visual analysis there was no significant difference in the overall numbers with increased visual uptake 24 % (36/151) in the aneurysm group vs. 19 % (30/159) in the controls, p = ns. SUV max was slightly lower in the aneurysm group vs. controls (mean (2 SD) 1.75(0.79) vs. 1.84(0.58), p = 0.02). However there was no difference in TBR between the AAA group and controls (mean (2 SD) 1.03 (0.46) vs. 1.05(0.31), p = 0.36). During a median 18 (interquartile range 8-35) months' follow-up 20 were repaired and four were confirmed ruptured. The level of metabolic activity as assessed by 18 F-FDG PET/CT in infra-renal AAA does not correlate with aortic size and does not differ between aneurysms and matched controls. (orig.)

  7. Clinical experience of titanium cerebral aneurysm clips. Evaluation of artifact of CT and MRI

    International Nuclear Information System (INIS)

    Ninomiya, Takashi; Kato, Yoko; Sano, Hirotoshi

    1996-01-01

    The titanium aneurysm clips manufactured by AESCULAP Company are expected to be useful, not only for clinical applications, but also for reducing artifacts in post-operative CT and MRI. We carried out an investigation of the behavior of the new Yasargil titanium clips in a 1.5T MR imager. The new titanium clips showed considerably smaller clip-induced MR and CT artifacts than phynox and elgiloy clips. No movement of the titanium clips was seen by introducing them to the MR imager. Subsequent to these experimental studies, we applied titanium clips to 25 cerebral aneurysms. Post-operative CT, especially helical scanning CT and MR showed minimal artifacts, leading to the conclusion that the titanium clips are better than the other types of clips for the evaluation of post-operative neuroradiological images. (author)

  8. Digital subtraction CT angiography for the detection of posterior inferior cerebellar artery aneurysms: comparison with digital subtraction angiography

    Energy Technology Data Exchange (ETDEWEB)

    Chen, Guo Zhong; Luo, Song; Zhou, Chang Sheng; Zhang, Long Jiang; Lu, Guang Ming [Jinling Hospital, Medical School of Nanjing University, Department of Medical Imaging, Nanjing, Jiangsu (China)

    2017-09-15

    To evaluate the diagnostic accuracy of digital subtraction CT angiography (DS-CTA) in detecting posterior inferior cerebellar artery (PICA) aneurysms with digital subtraction angiography (DSA) as reference standard. A total of 115 patients, including 56 patients diagnosed with PICA aneurysms by CTA or DSA and 59 non-PICA-aneurysm patients were included in this retrospective study. All patients underwent DS-CTA and DSA. The site of PICA aneurysms and the pattern of haemorrhage were analysed. Sensitivity and specificity of DS-CTA without and with combining haemorrhage pattern in diagnosing PICA aneurysms were evaluated on a per patient and per aneurysm basis with DSA. Of 115 patients, 56 patients (48.7%) had 61 PICA aneurysms (size range, 1.1-13.5 mm; mean size, 4.9 ± 2.8 mm) on DSA. The sensitivity and specificity in depicting PICA aneurysms were 89.3% and 96.6% on a per patient basis and 90.2% and 93.4% on a per aneurysm basis, while the corresponding values were 94.6% and 96.6% on a per patient basis and 95.1% and 93.4% on a per aneurysm basis when combining with haemorrhage site. DS-CTA has a high sensitivity and specificity in detecting PICA aneurysms compared with DSA. It may be helpful for clinical diagnosis of PICA aneurysms to combine with haemorrhage sites. (orig.)

  9. Subclavian Aberrant right artery aneurysm causing a common carotid trunk: findings in CT and MR

    International Nuclear Information System (INIS)

    Quiroga Gomez, S.; Alvarez Castells, A.; Dominguez Oronoz, R.; Gifre Bassols, L.

    1995-01-01

    We present a case of aberrant right subclavian artery aneurysm causing dysphagia, dysphonia, and Claude-Bernard-Horner's syndrome by compression of adjacent structures, initially diagnosed with plain chest radiography and barium-swallow examination. CT and MRI confirmed this vascular anomaly and showed a common carotid trunk, associated to aberrant subclavian artery in 29% of cases. (Author) 10 refs

  10. Combined open proximal and stent-graft distal repair for distal arch aneurysms: an alternative to total debranching.

    Science.gov (United States)

    Zierer, Andreas; Sanchez, Luis A; Moon, Marc R

    2009-07-01

    We present herein a novel, combined, simultaneous open proximal and stent-graft distal repair for complex distal aortic arch aneurysms involving the descending aorta. In the first surgical step, the transverse arch is opened during selective antegrade cerebral perfusion, and a Dacron graft (DuPont, Wilmington, DE) is positioned down the descending aorta in an elephant trunk-like fashion with its proximal free margin sutured circumferentially to the aorta just distal to the left subclavian or left common carotid artery. With the graft serving as the new proximal landing zone, subsequent endovascular repair is performed antegrade during rewarming through the ascending aorta.

  11. Radiological findings of dissecting aneurysm -a correlative study of CT with angiography-

    International Nuclear Information System (INIS)

    Bae, Tae Yeong; Park, Jae Hyung; Kim, Seung Hyup; Han, Man Chung

    1987-01-01

    This study comprised 16 patients with aortic dissecting aneurysm who were admitted to Seoul National University Hospital from May 1984 to January 1987. CT findings in 16 cases of aortic dissecting aneurysm were correlated with angiographic findings retrospectively. The results were analysed. 1. Number of male was 11 and that of female was 5. Male patients in fifties were most common and 4 in number. 13 patients had hypertension or history of hypertension among 14 patients. There were one case of Marfan's syndrome, preeclampsia and Takayasu's arteritis respectively. 2. There were 5 cases of DeBakey type I, 1 case of type II and 9 cases of types III dissecting aneurysm. Type III was most common. 3. CT confirmed as superior vena cava which was not identified whether it was superior vena cava or unopacified false lumen by angiography in one case. Regarding distal extent, authors defined A whose extent was proximal to diaphragm and B beyond it for convenience sake. There was one false negative case in CT among 16 cases which was diagnosed as dissecting aneurysm type IIIB by angiography and confirmed as type III surgically. One case was diagnosed as type IB by CT and as type IIIB by angiography and confirmed as type I surgically. Extent was more accurate in CT than angiography. One case was diagnosed as type II by CT but misdiagnosed as right atrial tumor by angiography. 4. Diagnostic sensitivities of CT and angiography in this study were 94% (15/16) respectively. CT was more advantageous in hemothorax, hemopericardium, hemomediastinum, unopacified false lumen, aortic wall calcification and getting information about mediastinum. In angiography aortic regurgitation and tear site and involvement of abdominal vessels could be observed

  12. Radiological findings of dissecting aneurysm -a correlative study of CT with angiography-

    Energy Technology Data Exchange (ETDEWEB)

    Bae, Tae Yeong; Park, Jae Hyung; Kim, Seung Hyup; Han, Man Chung [College of Medicine, Seoul National University, Seoul (Korea, Republic of)

    1987-06-15

    This study comprised 16 patients with aortic dissecting aneurysm who were admitted to Seoul National University Hospital from May 1984 to January 1987. CT findings in 16 cases of aortic dissecting aneurysm were correlated with angiographic findings retrospectively. The results were analysed. 1. Number of male was 11 and that of female was 5. Male patients in fifties were most common and 4 in number. 13 patients had hypertension or history of hypertension among 14 patients. There were one case of Marfan's syndrome, preeclampsia and Takayasu's arteritis respectively. 2. There were 5 cases of DeBakey type I, 1 case of type II and 9 cases of types III dissecting aneurysm. Type III was most common. 3. CT confirmed as superior vena cava which was not identified whether it was superior vena cava or unopacified false lumen by angiography in one case. Regarding distal extent, authors defined A whose extent was proximal to diaphragm and B beyond it for convenience sake. There was one false negative case in CT among 16 cases which was diagnosed as dissecting aneurysm type IIIB by angiography and confirmed as type III surgically. One case was diagnosed as type IB by CT and as type IIIB by angiography and confirmed as type I surgically. Extent was more accurate in CT than angiography. One case was diagnosed as type II by CT but misdiagnosed as right atrial tumor by angiography. 4. Diagnostic sensitivities of CT and angiography in this study were 94% (15/16) respectively. CT was more advantageous in hemothorax, hemopericardium, hemomediastinum, unopacified false lumen, aortic wall calcification and getting information about mediastinum. In angiography aortic regurgitation and tear site and involvement of abdominal vessels could be observed.

  13. Midterm results of endovascular stent graft treatment for descending aortic aneurysms including high-risk patients

    Directory of Open Access Journals (Sweden)

    Gussmann, Andreas

    2006-04-01

    Full Text Available Methods: 21 patients (17 men, 4 women; mean age 66.1 years, range 29-90 years with 15 true aneurysms, and 6 type B-dissections were treated by implantation of a TalentTM Endoluminal Stentgraft System from February 2000 to July 2003. In 3 cases it was necessary to overstent the left subclavian artery, in 1 case to overstent the left common carotid. Results: 2 patients (9.5% died during the first 30 days (1 myocardial infarction, 1 pneumonia. Two patients (9.5% suffered from cerebral ischemia and needed revascularisation. No paraplegia, no stroke occurred. One endoleak required additional stenting. No patient needed conversion. Follow-up, average 25.4 months (range 0-39, was 100% complete. During this another two patients died of myocardial infarction i.e. 9.5% (the above mentioned endoleak, but no late migration were detected in the remaining patients. In all cases the graft lumen stayed patent. Conclusions: Treatment of descending thoracic aortic aneurysm with an endovascular approach has acceptable mortality and morbidity-rates even in high risk patients. Procedural overstenting of the subclavian artery requires subclavian revascularisation in a minority of cases.

  14. Intracranial aneurysms: reproduction of the surgical view using 3D-CT angiography

    Energy Technology Data Exchange (ETDEWEB)

    Siablis, Dimitrios [Department of Radiology, School of Medicine, University of Patras, Rion GR 26500 (Greece)]. E-mail: siablis@med.upatras.gr; Kagadis, George C. [Department of Medical Physics, School of Medicine, University of Patras, Rion GR 26500 (Greece); Karamessini, Maria T. [Department of Radiology, School of Medicine, University of Patras, Rion GR 26500 (Greece); Konstantinou, Dimitrios [Department of Neurosurgery, School of Medicine, University of Patras, Rion GR 26500 (Greece); Karnabatidis, Dimitrios [Department of Radiology, School of Medicine, University of Patras, Rion GR 26500 (Greece); Petsas, Theodore [Department of Radiology, School of Medicine, University of Patras, Rion GR 26500 (Greece); Nikiforidis, George C. [Department of Medical Physics, School of Medicine, University of Patras, Rion GR 26500 (Greece)

    2005-07-01

    Our purpose was to describe a technique for simulating the surgical view of ruptured intracranial aneurysms, using volume-rendering techniques in spiral computed tomography (CT) angiography data. The 3D (three-dimensional) rendered images were assessed by a team consisted of four radiologists, one neurosurgeon and one medical physicist. The resultant 'surgical view' image was standardized in space using a three-dimensional coordinate system, which allowed for its reproduction in the operating theatre. The surgical views are a potentially useful tool for the surgical planning of intracranial aneurysms.

  15. Intracranial aneurysms: reproduction of the surgical view using 3D-CT angiography

    International Nuclear Information System (INIS)

    Siablis, Dimitrios; Kagadis, George C.; Karamessini, Maria T.; Konstantinou, Dimitrios; Karnabatidis, Dimitrios; Petsas, Theodore; Nikiforidis, George C.

    2005-01-01

    Our purpose was to describe a technique for simulating the surgical view of ruptured intracranial aneurysms, using volume-rendering techniques in spiral computed tomography (CT) angiography data. The 3D (three-dimensional) rendered images were assessed by a team consisted of four radiologists, one neurosurgeon and one medical physicist. The resultant 'surgical view' image was standardized in space using a three-dimensional coordinate system, which allowed for its reproduction in the operating theatre. The surgical views are a potentially useful tool for the surgical planning of intracranial aneurysms

  16. Role of F-18 FDG PET/CT in the management of infected abdominal aortic aneurysm due to salmonella

    Energy Technology Data Exchange (ETDEWEB)

    Choi, Seung Jin; Lee, Jin Soo; Cheong, Moon Hyun; Byun, Sung Su; Hyun, In Young [Inha University College of Medicine, Incheon (Korea, Republic of)

    2007-12-15

    We present a case of infected abdominal aortic aneurysm due to salmonella enteritidis. F-18 FDG PET/CT was performed to diagnosis and during follow-up after antibiotic treatment. Computed tomography (CT) is considered to be the best diagnostic imaging modality in infected aortic lesions. In this case, a combination of CT and FDG PET/CT provided accurate information for the diagnosis of infected abdominal aortic aneurysm. Moreover, FDG PET/CT made an important contribution of monitoring disease activity during antibiotic treatment.

  17. Endovascular Repair of Acute Symptomatic Pararenal Aortic Aneurysm With Three Chimney and One Periscope Graft for Complete Visceral Artery Revascularization

    International Nuclear Information System (INIS)

    Brechtel, Klaus; Ketelsen, Dominik; Endisch, Andrea; Heller, Stephan; Heuschmid, Martin; Stock, Ulrich A.; Kalender, Guenay

    2012-01-01

    PurposeTo describe a modified endovascular technique for complete revascularization of visceral and renal arteries in symptomatic pararenal aortic aneurysm (PRAA).TechniqueArterial access was surgically established in both common femoral arteries (CFAs) and the left subclavian artery (LSA). Revascularization of the left renal artery, the celiac trunk, and the superior mesenteric artery was performed through one single sheath via the LSA. Suitable covered stents were put in the aortic branches but not deployed. The right renal artery was accessed over the left CFA. Due to the longitudinal extension of the presented aneurysm two stent-grafts were introduced via the right CFA. After deploying the aortic stent-grafts, all covered stents in the side branches were deployed consecutively with a minimum overlap of 5 mm over the cranial and caudal stent-graft edges. Simultaneous ballooning was performed to fully expand all stent-grafts and warranty patency. Conclusion: This is the first report in the literature of chimney grafting in PRAA for complete revascularization of visceral and renal branches by using more than two covered stents introduced from one side through one single sheath. However this technique is modified, it should be used only in bailout situations when branched stent-grafts are not available and/or surgery is not suitable.

  18. Early evaluation of coronary artery bypass grafts: CT or selective angiography

    International Nuclear Information System (INIS)

    Wilson, P.C.; Gutierrez, O.; Moss, A.

    1984-01-01

    A prospective study was performed in 27 patients to compare the value of computed tomography and selective angiography in assessing coronary artery graft patency in the early post-operative period. The sensitivity of CT to graft patency was 85% with no falsely patent determinations. Dynamic CT was not found useful in predicting graft stenosis. There were no complications associated with CT studies, and two related to selective angiography. It is concluded that CT is the procedure of choice for graft evaluation in the early post-operative period; but that angiography is mandatory for the assessment of late symptom recurrence. A review is made of the results described in previous series. (orig.)

  19. Evaluation of cine CT in the investigation of patients with recurrent symptoms following coronary bypass grafting

    International Nuclear Information System (INIS)

    Rees, M.R.; MacMillan, R.M.; Eldredge, W.J.; Maranhao, V.

    1986-01-01

    Between May 1985 and July 1986, cine-CT was performed in 84 consecutive patients to evaluate graft patency and ventricular function. Only three studies (4%) were unsatisfactory. Compared to catheterization, an accuracy of 94% was found for graft patency, with a significant correlation for ejection fraction (r = .93). Close agreement with angiography was demonstrated for cine-CT detection of left ventricular wall motion abnormalities and graft flow. Compared to surgical placement, cine-CT localization of grafts in major coronary territories was 98% accurate. Despite a significant learning curve in study interpretation, cine-CT can be used in place of catheterization in the evaluation of symptomatic postgraft patients

  20. Transretroperitoneal CT-guided Embolization of Growing Internal Iliac Artery Aneurysm after Repair of Abdominal Aortic Aneurysm: A Transretroperitoneal Approach with Intramuscular Lidocaine Injection Technique

    Energy Technology Data Exchange (ETDEWEB)

    Park, Joon Young, E-mail: pjy1331@hanmail.net; Kim, Shin Jung, E-mail: witdd2@hanmail.net; Kim, Hyoung Ook, E-mail: chaos821209@hanmail.net [Chonnam National University Hospital, Department of Radiology (Korea, Republic of); Kim, Yong Tae, E-mail: mono-111@hanmail.net [Chonnam National University Hwasun Hospital, Department of Radiology (Korea, Republic of); Lim, Nam Yeol, E-mail: apleseed@hanmail.net; Kim, Jae Kyu, E-mail: kjkrad@jnu.ac.kr [Chonnam National University Hospital, Department of Radiology (Korea, Republic of); Chung, Sang Young, E-mail: sycpvts@jnu.ac.kr; Choi, Soo Jin Na, E-mail: choisjn@jnu.ac.kr; Lee, Ho Kyun, E-mail: mhaha@hanmail.net [Chonnam National University Hospital, Department of Surgery (Korea, Republic of)

    2015-02-15

    This study was designed to evaluate the efficacy and safety of CT-guided embolization of internal iliac artery aneurysm (IIAA) after repair of abdominal aortic aneurysm by transretroperitoneal approach using the lidocaine injection technique to iliacus muscle, making window for safe needle path for three patients for whom CT-guided embolization of IIAA was performed by transretroperitoneal approach with intramuscular lidocaine injection technique. Transretroperitoneal access to the IIAA was successful in all three patients. In all three patients, the IIAA was first embolized using microcoils. The aneurysmal sac was then embolized with glue and coils without complication. With a mean follow-up of 7 months, the volume of the IIAAs remained stable without residual endoleaks. Transretroperitoneal CT-guided embolization of IIAA using intramuscular lidocaine injection technique is effective, safe, and results in good outcome.

  1. Detection and evaluation of intracranial aneurysms with 16-row multislice CT angiography

    International Nuclear Information System (INIS)

    Tipper, G.; U-King-Im, J.M.; Price, S.J.; Trivedi, R.A.; Cross, J.J.; Higgins, N.J.; Farmer, R.; Wat, J.; Kirollos, R.; Kirkpatrick, P.J.; Antoun, N.M.; Gillard, J.H.

    2005-01-01

    AIM: The aim of this study was to assess the usefulness of 16-row multislice CT angiography (CTA) in evaluating intracranial aneurysms, by comparison with conventional digital subtraction angiography (DSA) and intraoperative findings. METHODS: A consecutive series of 57 patients, scheduled for DSA for suspected intracranial aneurysm, was prospectively recruited to have CTA. This was performed with a 16-detector row machine, detector interval 0.75 mm, 0.5 rotation/s, table speed 10 mm/rotation and reconstruction interval 0.40 mm. CTA studies were independently and randomly assessed by two neuroradiologists and a vascular neurosurgeon blinded to the DSA and surgical findings. Review of CTA was performed on workstations with an interactive 3D volume-rendered algorithm. RESULTS: DSA or intraoperative findings or both confirmed 53 aneurysms in 44 patients. For both independent readers, sensitivity and specificity per aneurysm of DSA were 96.2% and 100%, respectively. Sensitivity and specificity of CTA were also 96.2% and 100%, respectively. Mean diameter of aneurysms was 6.3 mm (range 1.9 to 28.1 mm, SD 5.2 mm). For aneurysms of less than 3 mm, CTA had a sensitivity of 91.7% for each reader. Although the neurosurgeon would have been happy to proceed to surgery on the basis of CTA alone in all cases, he judged that DSA might have provided helpful additional anatomical information in 5 patients. CONCLUSION: The diagnostic accuracy of 16-slice CTA is promising and appears equivalent to that of DSA for detection and evaluation of intracranial aneurysms. A strategy of using CTA as the primary imaging method, with DSA reserved for cases of uncertainty, appears to be practical and safe

  2. Dissecting aneurysm of the cervical internal carotid artery. Cervical CT scan findings and treatment - case report

    Energy Technology Data Exchange (ETDEWEB)

    Itoh, Yoshihiro; Itoyama, Youichi; Fukumura, Akinobu; Matsukado, Yasuhiko; Kodama, Takafumi

    1987-06-01

    On lifting a heavy case, a 51-year-old male experienced a sudden onset of headache with giddiness and clouded vision. A week later, vertigo and right hand numbness were added to his symptoms. The next day anisocoria (right > left) and dilation of the left retinal veins were noted. Cranial computed tomography (CT) scan appeared normal and there were no other remarkable neurological findings. The patient was treated conservatively for cerebral infarction, however, the headache worsened and diplopia occurred. Neurological examination on admission revealed nothing unusual except for left Horner's syndrome. Physical examination showed a palpable sausage-like painless tumor on the left side of the neck. Angiography showed a narrowing of the internal carotid artery in the cervical region with a small dissecting aneurysm at the C3 level. Cervical CT scan at the upper C3 level showed a low density lunar defect in the high density section of the enlarged left internal carotid artery. The patient was operated on by superficial temporal artery-middle cerebral artery anastomosis to increase the intracranial blood flow. Postoperatively the symptoms were quickly relieved. Angiography 1 month later showed less narrowing of the carotid artery, though the dissecting aneurysm still remained. Postoperative cervical CT scan showed the left internal carotid artery to be of normal size. The patient returned to his work in normal condition 2 months later. It is emphasized that cervical CT scan may be useful in the diagnosis of this unusual type of cervical dissecting aneurysm.

  3. Dissecting aneurysm of the cervical internal carotid artery. Cervical CT scan findings and treatment - case report

    Energy Technology Data Exchange (ETDEWEB)

    Itoh, Yoshihiro; Itoyama, Youichi; Fukumura, Akinobu; Matsukado, Yasuhiko; Kodama, Takafumi

    1987-06-01

    On lifting a heavy case, a 51-year-old male experienced a sudden onset of headache with giddiness and clouded vision. A week later, vertigo and right hand numbness were added to his symptoms. The next day anisocoria (right > left) and dilation of the left retinal veins were noted. Cranial computed tomography (CT) scan appeared normal and there were no other remarkable neurological findings. The patient was treated conservatively for cerebral infarction, however, the headache worsened and diplopia occurred. Neurological examination on admission revealed nothing unusual except for left Horner's syndrome. Physical examination showed a palpable sausage-like painless tumor on the left side of the neck. Angiography showed a narrowing of the internal carotid artery in the cervical region with a small dissecting aneurysm at the C3 level. Cervical CT scan at the upper C3 level showed a low density lunar defect in the high density section of the enlarged left internal carotid artery. The patient was operated on by superficial temporal artery-middle cerebral artery anastomosis to increase the intracranial blood flow. Postoperatively the symptoms were quickly relieved. Angiography 1 month later showed less narrowing of the carotid artery, though the dissecting aneurysm still remained. Postoperative cervical CT scan showed the left internal carotid artery to be of normal size. The patient returned to his work in normal condition 2 months later. It is emphasized that cervical CT scan may be useful in the diagnosis of this unusual type of cervical dissecting aneurysm.

  4. CT scans of giant aneurysms in the vertebro-basilar artery

    International Nuclear Information System (INIS)

    Shishido, Toyofumi; Ohsugi, Tamotsu; Motozaki, Takahiko; Sakaki, Saburo; Matsuoka, Kenzo

    1980-01-01

    Clinical course and neurological and neuroradiological findings of giant aneurysms in the vertebro-basilar artery observed in two of our cases were discussed. The first case was a 66-year-old man. He complained of sensory disturbance over his left face and unstable gait for 2 years before admission. Neurological examinations on admission showed hypesthesia in the territory of the second branch of the left fifth cranial nerve, nystagmus, and a left cerebellar sign. No mental deterioration or pyramidal signs were noticed. Retrograde left brachial artery angiograms revealed a giant aneurysm with inferior pointing measuring 30 x 10 mm in diameter arising from the left superior cerebellar artery. Precontrast CT scans demonstrated a round, large, high-density area, cantaining a relatively low-density area within it, in the medioventral portion of the left cerebellum; a part of this high-density area was markedly enhanced in the postcontrast CT scan. No ventricular dilatations were noticed by CT scans. Direct surgery was abandoned due to the size and location of the aneurysm. No neurologically abnormal finding developed after discharge. The second case was a 61-year-old man. He complained of unstable gait for 2 years before admission. Neurological examinations on admission showed bilateral pyramidal sings (more pronounced on the left) and nystagmus. There were no cranial nerve palsy and no sensory disturbances. Precontrast CT scans showed a large, oval, high-density area in the medioventral portion of the right cerebellum, extending to the upper brainstem; a part of this high-density area was markedly enhanced in the postcontrast CT scans. Retrograde left brachial artery angiograms revealed that the fusiform aneurysm in the left vertebral, the basilar artery, and the dilated basilar artery ran 30 mm from the clivus, with a dorsal convex arch. (J.P.N.)

  5. Impact of contrast injection and stent-graft implantation on reproducibility of volume measurements in semiautomated segmentation of abdominal aortic aneurysm on computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Morin-Roy, Florence; Hadjadj, Sofiane; Thomas, Olivier; Yang, Dan Yang [Centre Hospitalier Universitaire de Montreal (CHUM), Hopital Notre-Dame, Department of Radiology, Montreal, Quebec (Canada); Kauffmann, Claude [University of Montreal, Centre de Recherche, Centre Hospitalier Universitaire de Montreal (CRCHUM), Montreal, Quebec (Canada); Tang, An [University of Montreal, Centre de Recherche, Centre Hospitalier Universitaire de Montreal (CRCHUM), Montreal, Quebec (Canada); Centre Hospitalier Universitaire de Montreal (CHUM), Hopital Saint-Luc, Department of Radiology, Montreal, Quebec (Canada); Piche, Nicolas [Object Research System, Montreal, Quebec (Canada); Elkouri, Stephane [Centre Hospitalier Universitaire de Montreal (CHUM), Hopital Hotel-Dieu, Department of Vascular surgery, Montreal, Quebec (Canada); Therasse, Eric [University of Montreal, Centre de Recherche, Centre Hospitalier Universitaire de Montreal (CRCHUM), Montreal, Quebec (Canada); Centre Hospitalier Universitaire de Montreal (CHUM), Hopital Hotel-Dieu, Department of Radiology, Montreal, Quebec (Canada); Soulez, Gilles [Centre Hospitalier Universitaire de Montreal (CHUM), Hopital Notre-Dame, Department of Radiology, Montreal, Quebec (Canada); University of Montreal, Centre de Recherche, Centre Hospitalier Universitaire de Montreal (CRCHUM), Montreal, Quebec (Canada)

    2014-07-15

    To assess the impact of contrast injection and stent-graft implantation on feasibility, accuracy, and reproducibility of abdominal aortic aneurysm (AAA) volume and maximal diameter (D-max) measurements using segmentation software. CT images of 80 subjects presenting AAA were divided into four equal groups: with or without contrast enhancement, and with or without stent-graft implantation. Semiautomated software was used to segment the aortic wall, once by an expert and twice by three readers. Volume and D-max reproducibility was estimated by intraclass correlation coefficients (ICC), and accuracy was estimated between the expert and the readers by mean relative errors. All segmentations were technically successful. The mean AAA volume was 167.0 ± 82.8 mL and the mean D-max 55.0 ± 10.6 mm. Inter- and intraobserver ICCs for volume and D-max measurements were greater than 0.99. Mean relative errors between readers varied between -1.8 ± 4.6 and 0.0 ± 3.6 mL. Mean relative errors in volume and D-max measurements between readers showed no significant difference between the four groups (P ≥ 0.2). The feasibility, accuracy, and reproducibility of AAA volume and D-max measurements using segmentation software were not affected by the absence of contrast injection or the presence of stent-graft. (orig.)

  6. CT findings of subarachnoid hemorrhage due to ruptured cerebral aneurysm with fundal hemorrhage

    International Nuclear Information System (INIS)

    Kashihara, Kengo; Yamashima, Tetsumori; Hasegawa, Takeshi; Kida, Shinya; Nitta, Hisashi; Yamamoto, Shinjiro

    1985-01-01

    CT scan and fundus oculi of subarachnoid hemorrhage due to ruptured cerebral aneurysm were investigated in 42 patients who were admitted between January, 1980, and August, 1984. Fundal hemorrhage (FH) was observed in 22 patients. The patients with FH showed a worse clinical grade (Hunt Kosnik) on admission than those without FH. The mortality rate of patients with FH was 64 %, much higher than the 5 % rate of those without FH. Moreover, the patients with FH showed more trouble in daily living than those without FH. CT scans of patients with FH usually showed severe subarachnoid hemorrhage (SAH), whereas those of patients without FH showed only mild hemorrhage. These findings suggest that fundal hemorrhage is caused by acute intracranial hypertension following subarachnoid hemorrhage due to a ruptured cerebral aneurysm. However, no significant correlation between the laterality of FH and the hemispheric dominancy of SAH could be demonstrated. (author)

  7. Arteriovenous fistula complicating iliac artery pseudo aneurysm: diagnosis by CT angiography.

    Science.gov (United States)

    Huawei, L; Bei, D; Huan, Z; Zilai, P; Aorong, T; Kemin, C

    2002-01-01

    Fistula formation to the inferior vena cava is a rare complication of aortic aneurysm which is often misdiagnosed clinically. In one hundred of reported arteriocaval fistulae, none was originating from the right common iliac artery. We report a case of ileo-caval fistula due to a iatrogenic pseudoaneurysm. High resolution 3D imaging using breath-hold CT angiography is highly specific in identifying the location, extent of the aortocaval fistula as well as the neighbouring anatomic structures.

  8. CT findings in ten patients with failed renal allografts: comparison with findings in functional grafts

    International Nuclear Information System (INIS)

    Gayer, Gabriela; Apter, Sara; Katz, Rama; Ben-David, Aharon; Katzir, Ze'ev; Hertz, Marjorie

    2000-01-01

    Our aim is to report the computed tomography (CT) features of the long-term failed renal allograft. Ten patients with failed renal transplants in whom the graft was left in situ underwent CT for various unrelated indications. The majority of the failed grafts showed marked shrinkage and coarse punctate diffuse parenchymal calcifications. Small cysts were seen in four grafts. A long-term failed renal transplant appeared on CT as a small rounded soft tissue mass. The graft was almost always heavily calcified. Lack of awareness of the nature of such a mass may mislead the radiologist in interpreting it as a space-occupying lesion

  9. Rupture of an aneurysm of the coronary sinus of Valsalva: diagnosis by helical CT angiography

    International Nuclear Information System (INIS)

    Azarine, A.; Lions, C.; Beregi, J.P.; Koussa, M.

    2001-01-01

    A 75-year-old man presented with a 5-day history of upper chest discomfort. On auscultation, there was a systolic murmur in the left parasternal area that radiated to the apex. Electrocardiography showed flat T waves in the anterior precordial leads. Chest X ray revealed mediastinal enlargement. Transthoracic echocardiography showed a dilated proximal ascending aorta with moderate aortic regurgitation. A contrast-enhanced helical CT scan, performed to eliminate an aortic dissection, showed a ruptured left coronary sinus of Valsalva aneurysm, confirmed at surgery. This case highlights the fact that helical CT, in patients with suspected aortic dissection, may reveal other pathology that accounts for the clinical presentation. (orig.)

  10. Rupture of an aneurysm of the coronary sinus of Valsalva: diagnosis by helical CT angiography

    Energy Technology Data Exchange (ETDEWEB)

    Azarine, A.; Lions, C.; Beregi, J.P. [Dept. of Vascular Surgery, Hopital Cardiologique, CHRU de Lille (France); Koussa, M. [Dept. of Vascular Radiology, Hopital Cardiologique, CHRU de Lille (France)

    2001-08-01

    A 75-year-old man presented with a 5-day history of upper chest discomfort. On auscultation, there was a systolic murmur in the left parasternal area that radiated to the apex. Electrocardiography showed flat T waves in the anterior precordial leads. Chest X ray revealed mediastinal enlargement. Transthoracic echocardiography showed a dilated proximal ascending aorta with moderate aortic regurgitation. A contrast-enhanced helical CT scan, performed to eliminate an aortic dissection, showed a ruptured left coronary sinus of Valsalva aneurysm, confirmed at surgery. This case highlights the fact that helical CT, in patients with suspected aortic dissection, may reveal other pathology that accounts for the clinical presentation. (orig.)

  11. 18F-FDG PET-CT uptake is a feature of both normal diameter and aneurysmal aortic wall and is not related to aneurysm size

    Energy Technology Data Exchange (ETDEWEB)

    Barwick, Tara D. [Imperial College Healthcare NHS Trust, Charing Cross Hospital, Department of Radiology/Nuclear Medicine, London (United Kingdom); Hammersmith Hospital, Department of Surgery and Cancer, Imperial College London, London (United Kingdom); Lyons, O.T.A.; Waltham, M. [King' s College London, BHF Centre of Research Excellence and NIHR Biomedical Research Centre at King' s Health Partners, Academic Department of Surgery, London (United Kingdom); Mikhaeel, N.G. [Guy' s and St Thomas' Foundation NHS Trust, Department of Oncology, London (United Kingdom); O' Doherty, M.J. [King' s Health Partners, Clinical PET Centre, St Thomas' Hospital, London (United Kingdom)

    2014-12-15

    Aortic metabolic activity is suggested to correlate with presence and progression of aneurysmal disease, but has been inadequately studied. This study investigates the 2-[{sup 18}F] fluoro-2-deoxy-D-glucose ({sup 18}F-FDG) uptake in a population of infra-renal abdominal aortic aneurysms (AAA), compared to a matched non-aneurysmal control group. The Positron Emission Tomography - Computed Tomography (PET/CT) database was searched for infra-renal AAA. Exclusion criteria were prior repair, vasculitis, and saccular/mycotic thoracic or thoraco-abdominal aneurysms. Matching of 159 non-aneurysmal (<3 cm diameter) controls from the same population was assessed. Infra-renal aortic wall FDG uptake was assessed using visual analysis; maximum standardized uptake value (SUV{sub max}) and target to background mediastinal blood pool ratio (TBR) were documented. Predictors of FDG uptake (age, sex, aortic diameter, hypertension, statin use, and diabetes) were assessed using univariate analysis. Follow-up questionnaires were sent to referring clinicians. Aneurysms (n = 151) and controls (n = 159) were matched (p > 0.05) for age, sex, diabetes, hypertension, smoking status, statin use, and indication for PET/CT. Median aneurysm diameter was 5.0 cm (range 3.2-10.4). On visual analysis there was no significant difference in the overall numbers with increased visual uptake 24 % (36/151) in the aneurysm group vs. 19 % (30/159) in the controls, p = ns. SUV{sub max} was slightly lower in the aneurysm group vs. controls (mean (2 SD) 1.75(0.79) vs. 1.84(0.58), p = 0.02). However there was no difference in TBR between the AAA group and controls (mean (2 SD) 1.03 (0.46) vs. 1.05(0.31), p = 0.36). During a median 18 (interquartile range 8-35) months' follow-up 20 were repaired and four were confirmed ruptured. The level of metabolic activity as assessed by {sup 18}F-FDG PET/CT in infra-renal AAA does not correlate with aortic size and does not differ between aneurysms and matched controls

  12. Spiral CT angiography and surgical correlations in the evaluation of intracranial aneurysms

    International Nuclear Information System (INIS)

    Preda, L.; Di Maggio, E.M.; La Fianza, A.; Dore, R.; Fulle, I.; Solcia, M.; Campani, R.; Gaetani, P.; Rodriguez y Baena, R.; Cecchini, A.; Infuso, L.

    1998-01-01

    We investigated the accuracy of spiral computed tomography angiography (CTA) in the detection and study of intracranial aneurysms by comparing CTA with selective angiograms and surgical findings. Twenty-six patients (9 men and 17 women; mean age 53.1 ± 1.8 years) with suspected intracranial aneurysms were submitted to CTA (1- to 2-mm slices, pitch 1:1, 24 s, RI = 1) after a conventional CT examination showing subarachnoid hemorrhage (SAH) in 19 cases and during neuroradiological investigations performed for other reasons in 7 cases. One hundred twenty to 150 ml iodate contrast agent (0.3-0.4 gI/ml) were injected intravenously at 5 ml/s rate and with 12- to 25-s delay calculated with a preliminary test bolus. Three-dimensional shaded surface display (3D SSD) and maximum intensity projection (MIP) reconstructions were obtained from axial images. Then, within 48 h, all patients were submitted to digital subtraction angiography (DSA), with separate assessment of CTA and DSA findings. Twenty-two aneurysms shown by CTA were confirmed at DSA and surgery (true positives), whereas the vascular lesion was not confirmed at DSA in 2 cases (false positives). The presence of intracranial aneurysms was excluded at both CTA and subsequent DSA in 7 cases (true negatives) and there were no false negatives; sensitivity was 100 %, specificity 77.8 %, and diagnostic accuracy 93.5 %. Computed tomography angiography aneurysm location was confirmed at surgery in all cases, with very high accuracy in assessing the presence of an aneurysm neck (100 %). Computed tomography angiography accurately depicted the aneurysm shape in 20 of 22 cases, but failed to depict its multilobed nature in 2 cases. The mean aneurysm diameter calculated at CTA was 0.99 ± 0.12 cm vs 1.09 ± 0.11 cm at surgery (p < 0.01). The present results suggest that the high sensitivity of CTA, if confirmed by further studies, might help in avoiding having to resort to arteriography after negative CTA in SAH patients. (orig.)

  13. Detection of thin wall regions of unruptured cerebral aneurysms by ECG synchronous reconstruction 3D-CT angiography (4D-CTA) using 16 slices per rotation CT

    International Nuclear Information System (INIS)

    Fujita, Shigekiyo

    2004-01-01

    The objective of this study was to evaluate the capability of electrocardiogram (ECG) synchronous reconstruction 3D-CT angiography (4D-CTA) using 16 sequence MD-CT to detect weak portions of unruptured cerebral aneurysm. 4D-CT angiography of unruptured cerebral aneurysms was performed on 26 patients, 28 cerebral aneurysms, using 16 sequence MD-CT (GE, HiLight Matrix II). Contrast material of iodine (300 mg/ml) was injected over 30 sec period into the ante-cubital vein with a rate of 0.06 ml/Kg/sec. ECG synchronous reconstruction images (10 images at intervals of 10% between R-R of ECG) were generated (GE, Workstation Advantage 4.1). After careful inspection of the wall motion of an aneurysm from many aspects, cine images were made from several directions. Acquisition of data required 9 seconds, total volume data were generated within 15 minutes, and ECG synchronous reconstruction image processing was performed in about 5 minutes. Animation creation for one direction was completed within one minute. Even in 3-mm aneurysms, changes of its form and size within a heartbeat were fully observed. Timing of maximum and minimum sizes were also recognized. The pulsatile changes and nipple extent, bleb, daughter, and dome of aneurysms were well visualized. The projecting motion of the pulsatory enlargement of nipple was detected in nine cases, and definite increases in bleb sizes were detected in five cases. Since the easily reptured thin walled portion of a cerebral aneurysm can be recognized by this method, 4D-CT angiography is likely to become indispensable in judging how to cope with unruptured cerebral aneurysms, in deciding whether to operate or observe. (author)

  14. Value of the quantity and distribution of subarachnoid haemorrhage on CT in the localization of ruptured cerebral aneurysm

    International Nuclear Information System (INIS)

    Karttunen, A.I.; Jartti, P.H.; Haapea, M.; Ukkola, V.A.; Sajanti, J.

    2003-01-01

    Computed tomography (CT) is the 'gold standard' for detecting subarachnoid haemorrhage (SAH) and digital subtraction angiography (DSA) for visualising the vascular pathology. We studied retrospectively 180 patients with subarachnoid haemorrhage (SAH) who underwent first non-enhanced computed tomography (CT), then digital subtraction angiography (DSA) and finally operative aneurysm clipping. Our aim was to assess if the location of the ruptured aneurysm could be predicted on the basis of the quantity and distribution of haemorrhage on the initial CT scan. 180 patients with SAH were retrospectively studied. All the CT and DSA examinations were performed at the same hospital. CT was performed within 24 hours after the initial haemorrhage. DSA was performed alter the CT, within 48 hours after the initial haemorrhage. Two neuroradiologists, blind to the DSA results, analysed and scored independently the quantity and distribution of the haemorrhage and predicted the site of the ruptured aneurysm on the basis of the non-enhanced CT. DSA provided the location of the ruptured aneurysm. All the patients were operated upon, and the location of the ruptured aneurysm was determined. The overall reliability value (r,-value) between the two neuroradiologists for locating all ruptured aneurysms was 0.780. The corresponding value for the right MCA was 0.911, that for the left MCA 0.877 and that for the AcoA 0.736. Not all of the rc-values were calculated, either because the location of the rupture was constant or because the number of ruptures in the vessel was too small. Subarachnoid haemorrhage with a parenchymal hematoma is an excellent predictor of the site of the ruptured aneurysm with a statistical significance of p = 0.003. The quantity and pattern of the blood clot an CT within the day of onset of SAH is a reliable and quick cool for locating a ruptured MCA or AcoA aneurysm. It is not, however, reliable for locating other ruptured aneurysms. Subarachnoid haemorrhage with a

  15. Tube Stent-Grafts for Infrarenal Aortic Aneurysm: A Matched-Paired Analysis Based on EUROSTAR Data

    International Nuclear Information System (INIS)

    Ruppert, Volker; Leurs, Lina J.; Hobo, Roel; Buth, Jacob; Rieger, Johannes; Umscheid, Thomas

    2007-01-01

    Objective. Tube stent-grafts for treatment of infrarenal aortic aneurysms (AAAs) are a nearly forgotten concept. For focal aortic pathologies tube stent-grafts may be a treatment option. We have performed a retrospective matched-paired analysis of the EUROSTAR registry regarding the outcome of tube vs. bifurcated stent-grafts for AAA. Tapered aortomonoiliac stent-grafts were not the objective of this study. Materials and methods. From July 1997 to June 2006, 7581 patients who underwent an endovascular AAA repair were entered in the EUROSTAR registry by 164 centers. One hundred fifty-three patients were treated with tube stent-grafts. For each of these 153 patients we selected one patient from a bifurcated stent-graft group (BGG-original, 7428 patients) matched according to gender, ASA, age, AAA diameter, and type of anesthesia. Differences in preoperative details between the two study groups were analyzed using chi-square test for discrete variables and Wilcoxon rank-sum test for continuous variables. Multivariate logistic regression analysis was performed on early complications. Midterm outcomes (>30 days) were analyzed by Kaplan-Meier and multivariate Cox proportional hazard model. Results. The duration of the procedure was shorter in the tube stent-graft group (TGG; 102.3 ± 52.2) than in BGG (128.3 ± 55.0; p 0.0002). Type II endoleak was less frequent in TGG (4.0%; mean follow-up, 23.12 ± 23.9 months) than in BGG (14.3%; mean follow-up, 20.77 ± 20.0 months; p = 0.0394). Type I endoleaks and migration were distributed equally, without significant differences between the groups. Combined 30-day and late mortality was higher for TGG (p = 0.0346) and was obviously not aneurysm related. Conclusions. We conclude that after selection of patients, tube stent-grafts for infrarenal aortic repair can be performed with great safety regarding endoleaks and migration. The combined higher 30-day mortality and non-aneurysm-related mortality during follow-up were mainly

  16. Use of modified Sandwich-graft technique to preserve hypogastric artery in EVAR treatment of complex aortic aneurysm anatomy.

    Science.gov (United States)

    Mosquera Arochena, N; Rodríguez Feijoo, G; Carballo Fernandez, C; Molina Herrero, F; Fernandez Lebrato, R; Barrios Castro, A; Garcia Fernandez, I

    2011-10-01

    Since the introduction of the first endoprosthetic devices, continuous development in techniques and implants has occurred, such as the introduction of a stent graft with branches designed to preserve antegrade flow in the hypogastric artery, a stent-graft designed to treat extreme neck angulation and iliac tortuosity, as well as "Sandwich" and "Chimney" techniques used to maintain perfusion in branch vessels originating in the region to be treated. This paper describes how the Sandwich-Graft technique was adapted, as described by Lobato et al., employing the Aorfix™ system (Lombard Medical) and the Viabahn™ (W.L.Gore) to preserve hypogastric flow in cases with extreme neck angulation and iliac tortuosity. The study included four patients treated from April 2010 until November 2010 with the modified Sandwich technique. All patients eligible for this approach were considered unfit for open repair and were not suitable for an iliac branch graft (Z-BIS Zenith™ Cook Medical). A bifurcated endograft was implanted with specific, in-situ, branching to the target hypogastric artery and achieved clinical and technical success, in all the patients. After a 11-month follow-up in two cases and a six-month follow-up in the other two, clinical results were successful. All patients were endoleak-free, had patent hypogastric branches and had shrinking or stable aneurysms. The initial experience shows that the Sandwich technique with the Aorfix™ stent-graft demonstrated to be effective in endovascular repair of abdominal aortic aneurysms in patients with aortoiliac anatomy hostile to preserving hypogastric artery patency. This graft allows a broader group of patients to be treated with endovascular repair without potential complications of hypogastric artery occlusion; however, further studies are needed to evaluate long-term results in larger numbers of patients.

  17. Optimal graft diameter and location reduce postoperative complications after total arch replacement with long elephant trunk for arch aneurysm.

    Science.gov (United States)

    Kondoh, Haruhiko; Funatsu, Toshihiro; Toda, Koich; Kainuma, Satoshi; Kuki, Satoru; Taniguchi, Kazuhiro

    2011-08-01

    Total arch replacement with an elephant trunk is a standard treatment for arch aneurysm, but serious complications, such as paraplegia and peripheral embolization caused by flapping of the elephant trunk, remain. Moreover, dilation of the descending aorta and retrograde flow into the peri-graft space at the distal elephant trunk are frequent problems. We hypothesized that optimal graft diameter and location would reduce complications after total arch replacement with a long elephant trunk by achieving complete thrombosis and minimal dilation of the descending aorta around the elephant trunk. We treated 65 patients with arch aneurysm by total arch replacement with a long elephant trunk anastomosed at the base of the innominate artery. The graft diameter was undersized (10%-20% of the distal aorta's diameter). Elephant trunk length was determined by preoperative computed tomography to locate the distal end at Th6 to Th8. Thrombosis around the elephant trunk, diameter of the descending aorta, and distance between the descending aorta and the graft near the distal end of the elephant trunk were evaluated using computed tomography. The distal end of the elephant trunk was located at Th 8 ± 1. There were no operative deaths, 3 patients (5%) died in the hospital, and 3 patients (5%) experienced spinal cord injury, including 1 in whom permanent paraplegia developed. Computed tomography revealed complete thrombosis around the elephant trunk in 58 patients (89%). The descending aorta did not dilate further, and distance between the descending aorta and the graft progressively decreased. Optimal graft diameter and location minimized postoperative complications, with complete thrombosis and no dilation of the descending aorta around the long elephant trunk in most patients. Copyright © 2011 The American Association for Thoracic Surgery. Published by Mosby, Inc. All rights reserved.

  18. Anatomic study of juxta renal aneurysms: impact on fenestrated stent-grafts.

    Science.gov (United States)

    Azzaoui, Richard; Sobocinski, Jonathan; Maurel, Blandine; D'Elia, Piervito; Perrot, Céline; Bianchini, Aurélia; Guillou, Matthieu; Haulon, Stéphan

    2011-04-01

    Fenestrated stent-grafts allow for treatment of patients with juxtarenal aneurysms (JRA) when they present with contraindications for conventional treatment. The fenestrated module is a custom-made module, specially designed to fit a specific patient, using computed tomographic scan measurements, which entails manufacturing delay and high cost. The aim of our study was to evaluate the possibility to reproduce the interrenal aorta anatomy to design a standard fenestrated module that would fit the maximum number of patients with JRA. On a three-dimensional working station, we analyzed 289 preoperative computed tomographic scan results of patients with JRA and who were treated with fenestrated stent-grafts comprising two fenestrations for the renal arteries and a scallop for the superior mesenteric artery (SMA). On curvilinear reconstructions, we successively measured the interrenal aorta diameter, its orientation, as well as the height of each renal ostium, taking the ostium center of the SMA as a reference mark. Later, a statistical analysis of these measures distribution was performed so as to design a fenestrated module that would fit the maximum number of patients. The center of the left renal artery presented with a median orientation of 82.5° (range, 37.5-150) and a median distance of 9 mm (range, 0-30), in relation to the SMA ostium. The ostium center of the right renal artery presented with a median orientation of 285° (range, 240-337.5) and a median distance of 8 mm (range, 3-30), in relation to the SMA ostium. By positioning the current renal fenestrations (6-mm wide), on the basis of the calculated median positions, in our series, only 20% of the patients could be treated with a standard fenestrated module. Should the diameter of these fenestrations be increased by 10 mm, it would then be possible to treat 50% of our patients. The anatomy of the interrenal aorta and its branches is quite reproducible to design standard fenestrated stent-grafts that could

  19. Hemodynamic and Anatomic Predictors of Renovisceral Stent-Graft Occlusion Following Chimney Endovascular Repair of Juxtarenal Aortic Aneurysms.

    Science.gov (United States)

    Tricarico, Rosamaria; He, Yong; Laquian, Liza; Scali, Salvatore T; Tran-Son-Tay, Roger; Beck, Adam W; Berceli, Scott A

    2017-12-01

    To identify anatomic and hemodynamic changes associated with impending visceral chimney stent-graft occlusion after endovascular aneurysm repair (EVAR) with the chimney technique (chEVAR). A retrospective evaluation was performed of computed tomography scans from 41 patients who underwent juxtarenal chEVAR from 2008 to 2012 to identify stent-grafts demonstrating conformational changes following initial placement. Six subjects (mean age 74 years; 3 men) were selected for detailed reconstruction and computational hemodynamic analysis; 4 had at least 1 occluded chimney stent-graft. This subset of repairs was systematically analyzed to define the anatomic and hemodynamic impact of these changes and identify signature patterns associated with impending renovisceral stent-graft occlusion. Spatial and temporal analyses of cross-sectional area, centerline angle, intraluminal pressure, and wall shear stress (WSS) were performed within the superior mesenteric and renal artery chimney grafts used for repair. Conformational changes in the chimney stent-grafts and associated perturbations, in both local WSS and pressure, were responsible for the 5 occlusions in the 13 stented branches. Anatomic and hemodynamic signatures leading to occlusion were identified within 1 month postoperatively, with a lumen area 25 Pa/mm (p=0.03), and systolic WSS >45 Pa (p=0.03) associated with future chimney stent-graft occlusion. Chimney stent-grafts at increased risk for occlusion demonstrated anatomic and hemodynamic signatures within 1 month of juxtarenal chEVAR. Analysis of these parameters in the early postoperative period may be useful for identifying and remediating these high-risk stent-grafts.

  20. Detection of intracranial aneurysms using multi-detector row CT 3D-angiography: comparison with operative findings

    Energy Technology Data Exchange (ETDEWEB)

    Han, You Mie; Lim, Soo Mee; Seo, Eui Kyo; Kim, Yoo Kyung [Mokdong Hospital, Ewha Womans University, Seoul (Korea, Republic of)

    2006-04-15

    To assess the efficacy of three-dimensional CT angiography (3D-CTA) using multi-detector row computed tomography (MDCT) in the evaluation of intracranial aneurysms in patients with non-traumatic acute subarachnoid hemorrhage and to describe those aneurysms which were not found 3D-CTA. 3D-CTA was done in 40 patients with non-traumatic subarachnoid hemorrhage by using a 16-slice MDCT; conventional digital subtraction angiography (DSA) was done in 36 of those patients within 12 hours. The CT and DSA images were reviewed by two radiologists and the site, size and neck of the aneurysms were evaluated. The results from these two modalities were then compared with the operative findings. We calculated the detection rates by 3D-CTA and DSA and evaluated the size differences of aneurysms diagnosed with 3D-DTA and those found at surgery. We also analyzed the locations and sizes of aneurysms missed by 3D-CTA and attempted to explain these false negatives. A total of 55 aneurysms were surgically confirmed in 40 patients. 48 of these were detected pre-operatively by 3D-CTA. Thus, the detection rate by 3D-CTA was 87%. The size difference of aneurysms as calculated by 3-D CTA and found operatively was as follows: less than 1 mm in 17 cases, within 1-2 mm in 15 cases, and more than 2 mm in 16 cases. Seven aneurysms were not detected by 3D-CTA. The major cause of these missed aneurysms was their small size. The undetected aneurysms were less than 2 mm in size, except for 2 instances of PCoA aneurysms. One case was not detected due to difficult image evaluation. A possible explanation of the one remaining missed aneurysms was the filling of the aneurismal sac by thrombosis. Though there were some limitations in the detection of aneurysms, 3D-CTA using 16-channel MDCT may provide sufficient pre-operative information for the management of patients with intracranial aneurysms in cases of emergency operations or DSA-failure.

  1. Detection of intracranial aneurysms using multi-detector row CT 3D-angiography: comparison with operative findings

    International Nuclear Information System (INIS)

    Han, You Mie; Lim, Soo Mee; Seo, Eui Kyo; Kim, Yoo Kyung

    2006-01-01

    To assess the efficacy of three-dimensional CT angiography (3D-CTA) using multi-detector row computed tomography (MDCT) in the evaluation of intracranial aneurysms in patients with non-traumatic acute subarachnoid hemorrhage and to describe those aneurysms which were not found 3D-CTA. 3D-CTA was done in 40 patients with non-traumatic subarachnoid hemorrhage by using a 16-slice MDCT; conventional digital subtraction angiography (DSA) was done in 36 of those patients within 12 hours. The CT and DSA images were reviewed by two radiologists and the site, size and neck of the aneurysms were evaluated. The results from these two modalities were then compared with the operative findings. We calculated the detection rates by 3D-CTA and DSA and evaluated the size differences of aneurysms diagnosed with 3D-DTA and those found at surgery. We also analyzed the locations and sizes of aneurysms missed by 3D-CTA and attempted to explain these false negatives. A total of 55 aneurysms were surgically confirmed in 40 patients. 48 of these were detected pre-operatively by 3D-CTA. Thus, the detection rate by 3D-CTA was 87%. The size difference of aneurysms as calculated by 3-D CTA and found operatively was as follows: less than 1 mm in 17 cases, within 1-2 mm in 15 cases, and more than 2 mm in 16 cases. Seven aneurysms were not detected by 3D-CTA. The major cause of these missed aneurysms was their small size. The undetected aneurysms were less than 2 mm in size, except for 2 instances of PCoA aneurysms. One case was not detected due to difficult image evaluation. A possible explanation of the one remaining missed aneurysms was the filling of the aneurismal sac by thrombosis. Though there were some limitations in the detection of aneurysms, 3D-CTA using 16-channel MDCT may provide sufficient pre-operative information for the management of patients with intracranial aneurysms in cases of emergency operations or DSA-failure

  2. False iliac artery aneurysm following renal transplantation

    DEFF Research Database (Denmark)

    Levi, N; Sønksen, Jens Otto Reimers; Schroeder, T V

    1999-01-01

    We report a very rare case of a false iliac artery aneurysm following renal transplantation. The patient was a 51-year-old women who presented with a painful 10 x 10 cm pulsating mass in her left iliac fossa. The patient had received a second cadaveric renal transplantation 5 years previously....... The graft never functioned and transplant nephrectomy was performed 2 weeks later. A CT-scanning showed a 10 x 10 cm large aneurysm arising from the left external iliac artery. At operation a large false aneurysm was identified arising from the original transplant anastomotic site. Due to the extent...

  3. Endovascular Aortic Aneurysm Repair with the Talent Stent-Graft: Outcomes in Patients with Large Iliac Arteries

    International Nuclear Information System (INIS)

    England, Andrew; Butterfield, John S.; McCollum, Charles N.; Ashleigh, Raymond J.

    2008-01-01

    The purpose of this study is to report outcomes following endovascular aneurysm repair (EVAR) of abdominal aortic aneurysm (AAA) in patients with ectatic common iliac arteries (CIAs). Of 117 AAA patients treated by EVAR between 1998 and 2005, 87 (74%) had CIAs diameters 18 but <25 mm. All patients were treated with Talent stent-grafts, 114 bifurcated and 3 AUI devices. Departmental databases and patient records were reviewed to assess outcomes. Technical success, iliac-related outcome, and iliac-related reintervention (IRSI) were analyzed. Patients with EVAR extending into the external iliac artery were excluded. Median (range) follow-up for the study group was 24 (1-84) months. Initial technical success was 98% for CIAs <18 mm and 100% for CIAs ≥18 mm (p = 0.551). There were three distal type I endoleaks (two in the ectatic group) and six iliac limb occlusions (one in an ectatic patient); there were no statistically significant differences between groups (p = 0.4). There were nine IRSIs (three stent-graft extensions, six femorofemoral crossover grafts); three of these patients had one or both CIAs ≥18 mm (p = 0.232). One-year freedom from IRSI was 92% ± 3% and 84% ± 9% for the <18-mm and ≥18-mm CIA groups, respectively (p = 0.232). We conclude that the treatment of AAA by EVAR in patients with CIAs 18-24 mm appears to be safe and effective, however, it may be associated with more frequent reinterventions.

  4. Resolution of Large Azygos Vein Aneurysm Following Stent-Graft Shunt Placement in a Patient with Ehlers-Danlos Syndrome Type IV

    International Nuclear Information System (INIS)

    D'Souza, Estelle S.; Williams, David M.; Deeb, G.M.; Cwikiel, Wojciech

    2006-01-01

    Ehlers-Danlos syndrome (EDS) type IV is a rare connective tissue disorder associated with thin-walled, friable arteries and veins predisposing patients to aneurysm formation, dissection, fistula formation, and vessel rupture. Azygos vein aneurysm is an extremely rare condition which has not been reported in association with EDS in the literature. We present a patient with EDS type IV and interrupted inferior vena cava (IVC) with azygos continuation who developed an azygos vein aneurysm. In order to decrease flow through the azygos vein and reduce the risk of aneurysm rupture, a stent-graft shunt was created from the right hepatic vein to the azygos vein via a transhepatic, retroperitoneal route. At 6 month follow-up the shunt was open and the azygos vein aneurysm had resolved

  5. Treatment of giant and large fusiform middle cerebral artery aneurysms with excision and interposition radial artery graft in a 4-year-old child: case report.

    Science.gov (United States)

    Mrak, Goran; Paladino, Josip; Stambolija, Vasilije; Nemir, Jakob; Sekhar, Laligam N

    2014-03-01

    We report an unusual case of complex giant and large fusiform aneurysms not amenable for clipping or coiling in a 4-year-old child managed with aneurysm resection and radial artery interposition graft. A 4-year-old child presented with repeated severe headache and vomiting. Computed tomography, magnetic resonance imaging, and magnetic resonance angiography and digital subtraction angiography showed a giant fusiform aneurysm on the right middle cerebral artery (MCA). Because of the complex shape, endovascular treatment or clip reconstruction was not possible, and a bypass procedure was planned. Right frontotemporal craniotomy and orbitotomy was performed. Two aneurysms involving the M1 segment of the MCA were found in line, 1 giant, and the other large in size. The aneurysms were resected and treated with short radial artery interposition graft, which was narrower than the proximal or distal MCA. The child recovered normally, and the bypass was patent after 1 year. Large fusiform MCA aneurysms may be difficult to treat, but there are treatment options that include a bypass procedure. Resection and short interposition radial artery graft is an excellent but rare treatment option in a very young child. This was a very successful treatment in this child.

  6. Aneurysm Repair

    Science.gov (United States)

    ... the aneurysm. The stent graft acts as a barrier between the blood and the diseased wall of ... Search THI Resources Office of Research Administration Library & Learning Resource Center Scientific Publications & Grants Visual Communications & Public ...

  7. Two cases of thrombosed giant middle cerebral aneurysms presenting an unusual low-density area on a CT scan

    International Nuclear Information System (INIS)

    Fuwa, Isao; Matsukado, Yasuhiko; Otsuka, Tadahiro; Kodama, Takafumi; Wada, Hidetaka.

    1985-01-01

    We describe two cases of thrombosed giant middle cerebral aneurysms presenting an unusual low-density area on a CT scan. The first case was a 53-year-old woman who presented progressive motor difficulty and mental disturbance. A CT scan showed a large, round, high-density area with a clear margin in the right temporal and paraventricular regions. A low-density area extended around the large high-density lesion, and the ventricular system was shifted to the contralateral side. A thrombosed giant aneurysm with significant brain edema was confirmed surgically. The second case was a 66-year-old woman who had a history of severe headache and vomiting. A CT scan showed a ring-like calcification located in the right basal ganglia. A cystic low density, which compressed the right anterior horn, was observed in the right frontal region. Right carotid angiography revealed an aneurysm arising from the M 1 portion. The patient died before surgical intervention; however, neuroradiological examination indicated a liquefied clot in the thrombosed giant aneurysm. The etiology of the unusual low density was discussed in relation to the CT findings of the giant aneurysm. (author)

  8. Two cases of thrombosed giant middle cerebral aneurysms presenting an unusual low-density area on a CT scan

    Energy Technology Data Exchange (ETDEWEB)

    Fuwa, Isao; Matsukado, Yasuhiko; Otsuka, Tadahiro; Kodama, Takafumi; Wada, Hidetaka

    1985-12-01

    We describe two cases of thrombosed giant middle cerebral aneurysms presenting an unusual low-density area on a CT scan. The first case was a 53-year-old woman who presented progressive motor difficulty and mental disturbance. A CT scan showed a large, round, high-density area with a clear margin in the right temporal and paraventricular regions. A low-density area extended around the large high-density lesion, and the ventricular system was shifted to the contralateral side. A thrombosed giant aneurysm with significant brain edema was confirmed surgically. The second case was a 66-year-old woman who had a history of severe headache and vomiting. A CT scan showed a ring-like calcification located in the right basal ganglia. A cystic low density, which compressed the right anterior horn, was observed in the right frontal region. Right carotid angiography revealed an aneurysm arising from the M/sub 1/ portion. The patient died before surgical intervention; however, neuroradiological examination indicated a liquefied clot in the thrombosed giant aneurysm. The etiology of the unusual low density was discussed in relation to the CT findings of the giant aneurysm.

  9. Common and uncommon CT findings in rupture and impending rupture of abdominal aortic aneurysms

    International Nuclear Information System (INIS)

    Ahmed, M.Z.; Ling, L.; Ettles, D.F.

    2013-01-01

    The rapid imaging evaluation and diagnosis of rupture and impending rupture of an abdominal aortic aneurysm (AAA) is imperative. This article describes the imaging findings of rupture, impending rupture, and other abdominal aortic abnormalities. It is important not to overlook AAA as the consequences can be life threatening. All patients who had open or endovascular repair of AAA rupture over 6 years (2008–2012) were identified from our departmental database. The computed tomography (CT) images of 99 patients were reviewed for relevant findings. The mean age of the patients was 65 years and 85% were male

  10. Primitive experience of three dimensional multi-slice spiral CT angiography for the follow-up of intracranial aneurysm clipping

    International Nuclear Information System (INIS)

    Yang Yunjun; Chen Weijian; Hu Zhangyong; Wu Enfu; Wang Meihao; Zhuge Qichuan; Zhongming; Cheng Jingliang; Ren Cuiping; Zhang Yong

    2008-01-01

    Objective To evaluate multi-slice three-dimensional CT angiography (MS 3D-CTA) for the follow-up of intracranial aneurysm clipping. Methods: MS 3D-CTA of 16 patients with intracranial aneurysm clipping were retrospectively analyzed. The patients were scanned on a 16-slice spiral CT (GE Lightspeed pro). Volume rendering(VR), thin maximum intensity projection(thin MIP) and multi-planar reconstruction (MPR) were employed in image postprocessing in all cases. Results: There were 17 clips in the 16 patients with aneurysm clipping. Six clips were located at the posterior communicating artery, 5 at the anterior communicating artery, 4 at the middle cerebral artery, and the remaining 2 clips were located at the pericallosal artery, in 1 patient. There were no abnormalities found in the aneurysm clipping region in 7 cases by MS 3D- CTA. There were residual aneurysm in 2 cases, parent artery stenosis in 4 cases, and artery spasm in 3 eases. There was no parent artery occlusion and clip displacement in all cases. VR showed excellent 3D spacial relations between the clip and parent artery in 12 cases, and showed good relations in 3 cases. The 1 case with 2 clips in the pericallosal artery showed heavy beam-hardening artifacts. The size and shape of aneurysm clips were clearly depicted by MPR and thin MIP, while 3D spacial relation of aneurysm clip and parent artery were poorly showed. Conclusion: MS 3D-CTA is a safe and efficient method for the follow-up of intracranialaneurysm clipping. Combined VR with MPR or thin MIP can well reveal postoperative changes after aneurysm clipping. (authors)

  11. Endovascular Treatment of Ruptured Abdominal Aneurysm into the Inferior Vena Cava in Patient After Stent Graft Placement

    International Nuclear Information System (INIS)

    Juszkat, Robert; Pukacki, Fryderyk; Zarzecka, Anna; Kulesza, Jerzy; Majewski, Waclaw

    2009-01-01

    We report the case of a patient who underwent endovascular repair and then reintervention as a result of the presence of a persistent endoleak complicated by an aortocaval fistula. A 76-year-old patient with a history of endovascular treatment for abdominal aortic aneurysm 2 years earlier had a palpable abdominal mass, high-output cardiac failure, and renal failure. A computed tomographic scan and angiography revealed bending of the right iliac limb, a type I endoleak, and rupture of the aneurysm into the inferior vena cava with aortocaval fistula formation. An iliac extension was positioned in the right external iliac artery. The procedure was finished successfully. Control angiography showed normal flow within the endoprosthesis, and both iliac arteries were without signs of endoleakage and aortocaval fistula. Ectatic common iliac artery may lead to a late distal attachment site endoleak. The application of a stent graft in cases of secondary aortocaval fistula after stent graft repair is a good option, particularly in emergency cases.

  12. Helical CT for emergency patients with cerebrovascular diseases. Diagnosis of cerebral aneurysms with subarachnoid hemorrhage (SAH) by three-dimensional CT angiography (3D-CTA)

    International Nuclear Information System (INIS)

    Matsumoto, Masato; Satoh, Naoki; Kobayashi, Touru; Kodama, Namio; Nakano, Masayuki; Watanabe, Youichi; Fujii, Masayuki

    1996-01-01

    Recently, the usefulness of three-dimensional CT angiography (3D-CTA) using helical CT has been reported. Although 3D-CTA has been applied for neurosurgical diseases, especially for surgical planning, it has not done for emergency patients because of the long time required for image reconstruction and location of a helical CT scanner. We studied emergency patients with SAH, and compared the 3D-CTA with angiography and surgical findings, using TOSHIBA X vigor. Twenty-two patients with SAH were evaluated. The helical CT was performed for 55 seconds with a bolus injection of 90 ml non-ionic, iodinated contrast medium at a rate of 3 ml/sec with a delay of 20 sec. Angiography was carried out immediately after the helical CT. Eighteen of 22 cases were operated on urgently. We were able to create the 3D-CTA in about 7 minutes, and diagnose aneurysms by the 3D-CTA before angiography. The 3D-CTA was able to demonstrate 30 of 31 aneurysms including 9 unruptured aneurysms. An unruptured internal carotid-posterior communicating artery aneurysm 1.3 mm in diameter and associated with a ruptured aneurysm was not detected by either the 3D-CTA or angiography. On the other hand, an unruptured Acom aneurysm 0.8 mm in diameter and associated with a ruptured aneurysm could be detected by the: 3D-CTA, but not by angiography. The 3D-CTA gave us useful information concerning the anatomical relationship of the aneurysm, its neck and parent artery, and the surrounding branches. There were no complications or side effects associated with the helical CT scan. Although the 3D-CTA requires further development of visualization of small arteries less than 1 mm in diameter, such as perforating arteries, subtraction technique of bony structure, and a method for checking cervical arteries, it is useful for diagnosis of emergency patients with SAH and urgent operations. We believe that an operation might be performed by only the 3D-CTA without the angiography in the near future. (author)

  13. Helical CT for emergency patients with cerebrovascular diseases. Diagnosis of cerebral aneurysms with subarachnoid hemorrhage (SAH) by three-dimensional CT angiography (3D-CTA)

    Energy Technology Data Exchange (ETDEWEB)

    Matsumoto, Masato; Satoh, Naoki; Kobayashi, Touru; Kodama, Namio; Nakano, Masayuki; Watanabe, Youichi; Fujii, Masayuki [Fukushima Medical School (Japan)

    1996-05-01

    Recently, the usefulness of three-dimensional CT angiography (3D-CTA) using helical CT has been reported. Although 3D-CTA has been applied for neurosurgical diseases, especially for surgical planning, it has not done for emergency patients because of the long time required for image reconstruction and location of a helical CT scanner. We studied emergency patients with SAH, and compared the 3D-CTA with angiography and surgical findings, using TOSHIBA X vigor. Twenty-two patients with SAH were evaluated. The helical CT was performed for 55 seconds with a bolus injection of 90 ml non-ionic, iodinated contrast medium at a rate of 3 ml/sec with a delay of 20 sec. Angiography was carried out immediately after the helical CT. Eighteen of 22 cases were operated on urgently. We were able to create the 3D-CTA in about 7 minutes, and diagnose aneurysms by the 3D-CTA before angiography. The 3D-CTA was able to demonstrate 30 of 31 aneurysms including 9 unruptured aneurysms. An unruptured internal carotid-posterior communicating artery aneurysm 1.3 mm in diameter and associated with a ruptured aneurysm was not detected by either the 3D-CTA or angiography. On the other hand, an unruptured Acom aneurysm 0.8 mm in diameter and associated with a ruptured aneurysm could be detected by the: 3D-CTA, but not by angiography. The 3D-CTA gave us useful information concerning the anatomical relationship of the aneurysm, its neck and parent artery, and the surrounding branches. There were no complications or side effects associated with the helical CT scan. Although the 3D-CTA requires further development of visualization of small arteries less than 1 mm in diameter, such as perforating arteries, subtraction technique of bony structure, and a method for checking cervical arteries, it is useful for diagnosis of emergency patients with SAH and urgent operations. We believe that an operation might be performed by only the 3D-CTA without the angiography in the near future. (author)

  14. Multislice CT angiography in the selection of patients with ruptured intracranial aneurysms suitable for clipping or coiling

    NARCIS (Netherlands)

    Westerlaan, H. E.; Gravendeel, J.; Fiore, D.; Metzemaekers, J. D. M.; Groen, R. J. M.; Mooij, J. J. A.; Oudkerk, M.

    2007-01-01

    Introduction We sought to establish whether CT angiography (CTA) can be applied to the planning and performance of clipping or coiling in ruptured intracranial aneurysms without recourse to intraarterial digital subtraction angiography (IA-DSA). Methods Over the period April 2003 to January 2006 in

  15. F-18-Fluorodeoxyglucose Positron Emission Tomography/CT Scanning in Diagnosing Vascular Prosthetic Graft Infection

    NARCIS (Netherlands)

    Saleem, Ben R.; Pol, Robert A.; Slart, Riemer H. J. A.; Reijnen, Michel M. P. J.; Zeebregts, Clark J.

    2014-01-01

    Vascular prosthetic graft infection (VPGI) is a severe complication after vascular surgery. CT-scan is considered the diagnostic tool of choice in advanced VPGI. The incidence of a false-negative result using CT is relatively high, especially in the presence of low-grade infections.

  16. Infundibular dilation and aneurysm at the origin of the posterior communicating artery: differential diagnosis by CT angiography

    Energy Technology Data Exchange (ETDEWEB)

    Min, Kyung-Jun; Yoon, Dae-Young [Hallym University College of Medicine, Department of Radiology, Kangdong Seong-Sim Hospital, Seoul (Korea, Republic of); Kim, Heung-Chul [Hallym University College of Medicine, Department of Radiology, Chuncheon Sacred Heart Hospital, Chuncheon (Korea, Republic of); Lee, Jong-Young; Cho, Byung-Moon [Hallym University College of Medicine, Department of Neurosurgery, Kangdong Seong-Sim Hospital, Seoul (Korea, Republic of)

    2014-11-15

    Infundibular dilation (ID) and aneurysm at the internal carotid artery (ICA)-posterior communicating artery (PComA) junction can be difficult to distinguish but may differ in clinical significance. The aim of this study was to evaluate the utility of CT angiography (CTA) in differentially diagnosing IDs and small unruptured aneurysms at the ICA-PComA junction. This retrospective study comprised 88 patients diagnosed with 107 protrusions (70 IDs and 37 aneurysms <5 mm; 19 bilateral lesions) at the ICA-PComA junction who underwent both CTA and digital subtraction angiography (DSA). Two neuroradiologists independently reviewed CTA and DSA images according to these criteria: (a) size (maximum dimension <3 or ≥3 mm), (b) shape (triangular or round/oval/irregular), (c) aneurysmal neck (absent or present), (d) horizontal direction (posteriomedial or posteriolateral), and (e) PComA origin (apex, no PComA, or base). The intermodality (between CTA and DSA) and interobserver (between the two readers) agreement were determined for each finding. We also evaluated the sensitivity and specificity of CTA for distinguishing ID and aneurysm, using DSA as the reference standard. The mean κ values of intermodality agreement for the size, shape, aneurysmal neck, horizontal direction, and PComA origin were 0.88, 0.87, 0.84, 0.71, and 0.56, respectively. All interobserver agreements of CTA and DSA were excellent. The sensitivity, specificity, and accuracy of CTA for differentiating aneurysms from IDs were 94.6, 100, and 98.0 %, respectively. CTA may be a useful noninvasive modality for differential diagnosis of ID and aneurysm at the ICA-PComA junction. (orig.)

  17. Assessment of coronary artery aneurysms in paediatric patients with Kawasaki disease by multidetector row CT angiography: feasibility and comparison with 2D echocardiography

    International Nuclear Information System (INIS)

    Chu, W.C.W.; Lam, W.W.M.; Mok, G.C.F.; Yam, M.; Sung, R.Y.T.

    2006-01-01

    Transthoracic ECHO is the locally accepted method for coronary surveillance of patients with Kawasaki disease but it may have limited visualization in the older child. To assess the feasibility of multidetector CT (MDCT) angiography in the follow-up of coronary artery aneurysms in children with previous Kawasaki disease. Six children (5 boys, 1 girl; mean age 11.5 years) with known Kawasaki disease and coronary artery involvement underwent CT coronary angiography using 16-detector MDCT. The visualized lengths and diameter of all coronary segments were measured. The number, size and location of coronary artery aneurysms were recorded and compared with recent ECHO. Twelve coronary artery aneurysms (seven saccular, five fusiform) were identified by MDCT angiography. One saccular aneurysm at the junction of the distal right coronary artery and posterior descending artery was not detected by ECHO while the remaining six in proximal segments were detected by both modalities. Two of five fusiform aneurysms were not detected by ECHO due to their small sizes. Excellent agreement was found between CT and ECHO for maximal diameter and length of the visualized aneurysms. MDCT angiography accurately defines coronary artery aneurysms. It is more sensitive for detecting aneurysms at distal coronary segments and fusiform aneurysms of small size

  18. Classification of non-aneurysmal subarachnoid haemorrhage: CT correlation to the clinical outcome

    International Nuclear Information System (INIS)

    Nayak, S.; Kunz, A.B.; Kieslinger, K.; Ladurner, G.; Killer, M.

    2010-01-01

    Aim: To propose a new computed tomography (CT)-based classification system for non-aneurysmal subarachnoid haemorrhage (SAH), which predicts patients' discharge clinical outcome and helps to prioritize appropriate patient management. Methods and materials: A 5-year, retrospective, two-centre study was carried out involving 1486 patients presenting with SAH. One hundred and ninety patients with non-aneurysmal SAH were included in the study. Initial cranial CT findings at admission were correlated with the patients' discharge outcomes measured using the Modified Rankin Scale (MRS). A CT-based classification system (type 1-4) was devised based on the topography of the initial haemorrhage pattern. Results: Seventy-five percent of the patients had type 1 haemorrhage and all these patients had a good clinical outcome with a discharge MRS of ≤1. Eight percent of the patients presented with type 2 haemorrhage, 62% of which were discharged with MRS of ≤1 and 12% of patients had MRS 3 or 4. Type 3 haemorrhage was found in 10%, of which 16% had good clinical outcome, but 53% had moderate to severe disability (MRS 3 and 4) and 5% were discharged with severe disability (MRS 5). Six percent of patients presented with type 4 haemorrhage of which 42% of the patients had moderate to severe disability (MRS 3 and 4), 42% had severe disability and one-sixth of the patients died. Highly significant differences were found between type 1(1a and 1b) and type 2 (p = 0.003); type 2 and type 3 (p = 0.002); type 3 and type 4 (p = 0.001). Conclusion: Haemorrhages of the type 1 category are usually benign and do not warrant an extensive battery of clinical and radiological investigations. Type 2 haemorrhages have a varying prognosis and need to be investigated and managed along similar lines as that of an aneurysmal haemorrhage with emphasis towards radiological investigation. Type 3 and type 4 haemorrhages need to be extensively investigated to find an underlying cause.

  19. Influence of endoleaks on aneurysm volume and hemodynamics after endovascular aneurysm repair

    International Nuclear Information System (INIS)

    Pitton, M.B.; Welter, B.; Schmenger, P.; Thelen, M.; Dueber, C.; Neufang, A.

    2003-01-01

    Purpose: To evaluate the aneurysm volume and the intra-aneurysmatic pressure and maximal pressure pulse (dp/dtmax) in completely excluded aneurysms and cases with endoleaks. Materials and Methods: In 36 mongrel dogs, experimental autologous aneurysms were treated with stent-grafts. All aortic side branches were ligated in 18 cases (group I) but were preserved in group II (n=18). Aneurysm volumes were calculated from CT scans before and after intervention, and from follow-up CT scans at 1 week, 6 weeks and 6 months. Finally, for hemodynamic measurements, manometer-tipped catheters were introduced into the excluded aneurysm sac (group I and II), selectively in endoleaks (group II), and intraluminally for aortic reference measurement. Systemic hypertension was induced by volume load and pharmacologic stress. Pressure curves and dp/dt were simultaneously recorded and the ratios of aneurysm pressure to systemic reference pressure calculated. Results: At follow-up, type-II, endoleaks were excluded in all cases of group I by selective angiography. In contrast, endoleaks were evident in all cases of group II. Volumetric analysis of the aneurysms showed a benefit for group I with an improved aneurysm shrinkage: ΔVolume +0.08%, -1.62% and -9.76% at 1 week, 6 weeks and 6 months follow-up (median, group I), compared to +1.43%, +0.67%, and -4.04% (group II), p [de

  20. Endovascular stent graft for treatment of complicated spontaneous dissection of celiac artery: Report of two cases

    Energy Technology Data Exchange (ETDEWEB)

    Kang, Ung Rae; Lee, Young Hwan [Dept. of Diagnostic Radiology, Catholic University of Daegu School of Medicine, Daegu (Korea, Republic of); Kim, Young Hwan [Dept. of Diagnostic Radiology, Dongsan Medical Center, Keimyung University School of Medicine, Daegu (Korea, Republic of)

    2013-06-15

    We report 2 cases of complicated spontaneous dissection of the celiac artery, which were successfully treated by a stent graft. The first patient was a 47-year-old man who presented with acute abdominal pain. CT scan showed ruptured saccular aneurysm with surrounding retroperitoneal hematoma. The second patient was a 57-year-old man with progressive dissecting aneurysm. Endovascular stent graft was placed in the celiac trunk to control bleeding, and to prevent rupture in each patient. Follow-up CT scans showed complete obliteration of a dissecting aneurysm.

  1. Early-Dynamic Positron Emission Tomography (PET)/Computed Tomography and PET Angiography for Endoleak Detection After Endovascular Aneurysm Repair.

    Science.gov (United States)

    Drescher, Robert; Gühne, Falk; Freesmeyer, Martin

    2017-06-01

    To propose a positron emission tomography (PET)/computed tomography (CT) protocol including early-dynamic and late-phase acquisitions to evaluate graft patency and aneurysm diameter, detect endoleaks, and rule out graft or vessel wall inflammation after endovascular aneurysm repair (EVAR) in one examination without intravenous contrast medium. Early-dynamic PET/CT of the endovascular prosthesis is performed for 180 seconds immediately after intravenous injection of F-18-fluorodeoxyglucose. Data are reconstructed in variable time frames (time periods after tracer injection) to visualize the arterial anatomy and are displayed as PET angiography or fused with CT images. Images are evaluated in view of vascular abnormalities, graft configuration, and tracer accumulation in the aneurysm sac. Whole-body PET/CT is performed 90 to 120 minutes after tracer injection. This protocol for early-dynamic PET/CT and PET angiography has the potential to evaluate vascular diseases, including the diagnosis of complications after endovascular procedures.

  2. Interventional procedures of the isolated iliac arterial aneurysm

    Energy Technology Data Exchange (ETDEWEB)

    Ohm, Joon Young [The Catholic Univ. of Korea College of Medicine, Bucheon (Korea, Republic of); Shin, Byung Seok; Ahn, Moon Sang [Chungnam National Univ. Hospital, Daejeon (Korea, Republic of); Park, Mi Hyun [Dankook Univ. Hospital, Cheonan (Korea, Republic of); Kim, Ho Jun [Konyang Univ. Hospital, Daejeon (Korea, Republic of)

    2012-05-15

    To report the results of treatment isolated iliac arterial aneurysms by interventional procedures. Over a period of 5 years, 7 isolated iliac artery aneurysms (4 in the common iliac artery, 3 in the internal iliac artery) in 7 patients (3 women, 4 men; mean age, 65.7 years) were treated using interventional procedures. The mean aneurysm size was 35 mm (range, 30-45 mm). The common iliac aneurysms were treated using a unilateral stent graft (2 balloon expandable, 2 self expandable) with coil embolization of the internal iliac artery (n = 3), except for 1 aneurysm that ruptured. Coil embolization alone was performed for aneurysms involving only the internal iliac artery (n = 3). All patients were treated successfully, except for 1 with an initial remnant of type 2 endoleak. There were no perioperative complications. No leakage or complication occurred at the mean follow up of 14 months (range 2-29 months). One patient with a ruptured aneurysm died of multi organ failure during the follow up period. Three aneurysms had decreased in size on follow up CT. Interventional procedures with stent grafting and coil embolization are safe and effective treatments for isolated iliac artery aneurysms.

  3. Multidetector CT findings of splenic artery aneurysm in children with chronic liver disease

    International Nuclear Information System (INIS)

    Ulu, Esra Meltem Kayahan; Kirbas, Ismail; Emiroglu, Feride Kural; Cakir, Banu; Harman, Ali; Coskun, Mehmet; Bakar, Coskun

    2008-01-01

    Splenic artery aneurysm (SAA) is a well-known complication of chronic liver disease and portal hypertension in adults. The incidence of SAA in children undergoing selective hepatic angiography prior to liver transplantation is reported as 4%, but there are few systematic studies. To investigate the SAAs detected by multidetector CT angiography (MDCTA) among children with chronic liver disease. A total of 124 children (71 girls, 53 boys; mean age 118 months; age range 5 days to 204 months) with chronic liver disease underwent MDCTA to display the vascular anatomy and any vascular complications during the pretransplantation period. Of these children, 23 also underwent coeliac angiography. The digital subtraction angiography (DSA) and MDCTA findings were compared. SAAs were detected in 13 children (10.4%); none was detectable by US. All patients had more than one aneurysm; ten patients had more than three. In all except one patient, the SAAs were located only in the intraparenchymal branches of the splenic artery; in one patient they were located in the intraparenchymal segment and in the distal third of the splenic artery. The mean size of the aneurysms was 6.5 mm (range 2.5-18 mm). All patients with aneurysms had splenomegaly and vascular collaterals. Nine of the children with SAAs had portal vein pathologies (two occlusions, two stenoses, five dilatations). A statistically significant difference existed with regard to the size of spleen (P < 0.05) and patient age (P < 0.05) between children with SAAs and children without SAAs. There was an increased risk of SAAs in patients with portal vein pathologies. In 19 patients without SAAs on MDCTA, no SAAs were seen on DSA. It is likely that the incidence of SAA in children with chronic liver disease will increase with improved survival of children with long-standing portal hypertension and chronic liver disease. MDCTA with multiplanar reconstruction is a noninvasive and effective means of imaging paediatric patients with

  4. Multidetector CT findings of splenic artery aneurysm in children with chronic liver disease

    Energy Technology Data Exchange (ETDEWEB)

    Ulu, Esra Meltem Kayahan; Kirbas, Ismail; Emiroglu, Feride Kural; Cakir, Banu; Harman, Ali; Coskun, Mehmet [Baskent University Faculty of Medicine, Department of Radiology, Ankara (Turkey); Bakar, Coskun [Baskent University Faculty of Medicine, Department of Public Health, Ankara (Turkey)

    2008-10-15

    Splenic artery aneurysm (SAA) is a well-known complication of chronic liver disease and portal hypertension in adults. The incidence of SAA in children undergoing selective hepatic angiography prior to liver transplantation is reported as 4%, but there are few systematic studies. To investigate the SAAs detected by multidetector CT angiography (MDCTA) among children with chronic liver disease. A total of 124 children (71 girls, 53 boys; mean age 118 months; age range 5 days to 204 months) with chronic liver disease underwent MDCTA to display the vascular anatomy and any vascular complications during the pretransplantation period. Of these children, 23 also underwent coeliac angiography. The digital subtraction angiography (DSA) and MDCTA findings were compared. SAAs were detected in 13 children (10.4%); none was detectable by US. All patients had more than one aneurysm; ten patients had more than three. In all except one patient, the SAAs were located only in the intraparenchymal branches of the splenic artery; in one patient they were located in the intraparenchymal segment and in the distal third of the splenic artery. The mean size of the aneurysms was 6.5 mm (range 2.5-18 mm). All patients with aneurysms had splenomegaly and vascular collaterals. Nine of the children with SAAs had portal vein pathologies (two occlusions, two stenoses, five dilatations). A statistically significant difference existed with regard to the size of spleen (P < 0.05) and patient age (P < 0.05) between children with SAAs and children without SAAs. There was an increased risk of SAAs in patients with portal vein pathologies. In 19 patients without SAAs on MDCTA, no SAAs were seen on DSA. It is likely that the incidence of SAA in children with chronic liver disease will increase with improved survival of children with long-standing portal hypertension and chronic liver disease. MDCTA with multiplanar reconstruction is a noninvasive and effective means of imaging paediatric patients with

  5. Chimney-Graft as a Bail-Out Procedure for Endovascular Treatment of an Inflammatory Juxtarenal Abdominal Aortic Aneurysm

    Directory of Open Access Journals (Sweden)

    Francesca Fratesi

    2015-01-01

    Full Text Available Inflammatory and juxtarenal Abdominal Aortic Aneurysm (j-iAAA represents a technical challenge for open repair (OR due to the peculiar anatomy, extensive perianeurysmal fibrosis, and dense adhesion to the surrounding tissues. A 68-year-old man with an 11 cm asymptomatic j-iAAA was successfully treated with elective EVAR and chimney-graft (ch-EVAR without postprocedural complications. Target vessel patency and normal renal function are present at 24-month follow-up. The treatment of j-iAAA can be technically challenging. ch-EVAR is a feasible and safe bail-out method for elective j-iAAA with challenging anatomy.

  6. Ischaemia of the medullary cone after stent-graft implantation in a patient with abdominal aortic aneurysm - a case study.

    Science.gov (United States)

    Wachowski, Mariusz; Polguj, Michał; Ścibór, Janusz; Majos, Agata

    2018-03-01

    Preoperative visualization of the Adamkiewicz artery - the vessel which is to a great extent responsible for supplying blood to the medullary cone - is an important step which must be taken before initiating restorative procedures in the aorta. We present a case of a 67-year-old patient who underwent an intravascular stent-graft implantation procedure, due to clinical signs of abdominal aortic aneurysm. Routine pre-operative computed tomography examination failed to demonstrate the Adamkiewicz artery. On the second day after the surgery, as a result of unexpected clinical deterioration, an magnetic resonance imaging examination of the lumbar spine was carried out. Based on the magnetic resonance imaging images and clinical manifestations the diagnosis of ischaemia of the medullary cone was made. In our work we also present a deep analysis of the anatomy of small-sized vessels supplying blood to the spinal cord and discuss effective techniques which enable visualization of the Adamkiewicz artery.

  7. Fenestrated endovascular aortic aneurysm repair using physician-modified endovascular grafts versus company-manufactured devices.

    Science.gov (United States)

    Dossabhoy, Shernaz S; Simons, Jessica P; Flahive, Julie M; Aiello, Francesco A; Sheth, Parth; Arous, Edward J; Messina, Louis M; Schanzer, Andres

    2017-12-07

    Fenestrated endografts are customized, patient-specific endovascular devices with potential to reduce morbidity and mortality of complex aortic aneurysm repair. With approval from the U.S. Food and Drug Administration, our center began performing fenestrated endovascular aneurysm repair through a physician-sponsored investigational device exemption (IDE #G130210), using both physician-modified endografts (PMEGs) and company-manufactured devices (CMDs). Because these techniques are associated with specific advantages and disadvantages, we sought to investigate differences in outcomes between PMEG and CMD cases. A single-institution retrospective review of all fenestrated endovascular aneurysm repairs was performed. The cohort was analyzed by device type (PMEG or CMD) after matching of cases on the basis of (1) number of target vessels intended for treatment, (2) extent of aneurysm, (3) aneurysm diameter, (4) device configuration, and (5) date of operation. Outcomes of ruptures, common iliac artery aneurysms, and aortic arch aneurysms were excluded. Demographics, operative details, perioperative complications, length of stay, and reinterventions were compared. For patients with >1 year of follow-up time, survival, type I or type III endoleak rate, target artery patency, and reintervention rate were estimated using the Kaplan-Meier method. Between November 30, 2010, and July 30, 2016, 82 patients were identified and matched. The cohort included 41 PMEG and 41 CMD patients who underwent repair of 38 juxtarenal (PMEG, 17; CMD, 21; P = .38), 14 pararenal (PMEG, 6; CMD, 8; P = .56), and 30 thoracoabdominal type I to type IV (PMEG, 18; CMD, 12; P = .17) aneurysms. There were significant differences in presentation requiring urgent aneurysm repair (PMEG, 9; CMD, 0; P = .002), total fluoroscopy time (PMEG, 76 minutes; CMD, 61 minutes; P = .02), volume of contrast material used (PMEG, 88 mL; CMD, 70 mL; P = .02), in-operating room to out-of-operating room time

  8. CT-control of the H-graft interposition mesocaval shunt patency

    Energy Technology Data Exchange (ETDEWEB)

    Partanen, P L.K.; Oksala, I

    1984-02-01

    A method for assessing the patency of the H-graft interposition mesocaval shunts by computerized tomography is described. Five patients with such shunts were examined with a 5.5 second CT scanner. After locating the graft a 50 cc bolus of 76% diatrizoate was injected into a cubital vein and 3-4 scans were executed at a preselected level. A distinct vessel like enhancement appeared if the shunt was open. With dynamic CT-scanning the flow can be demonstrated in graphical form as time-density curves.

  9. Variability of vascular CT measurement techniques used in the assessment abdominal aortic aneurysms

    International Nuclear Information System (INIS)

    England, Andrew; Niker, Amanda; Redmond, Claire

    2010-01-01

    Purpose: The aim of this project is to assess the variability of six CT measurement techniques for sizing abdominal aortic aneurysms (AAAs). Method: 37 CT scans with known AAAs were loaded on to a departmental picture archiving and communication system (PACS). A team of three observers, with experience in aortic CT measurements and the PACS performed a series of 2D and 3D measurements on the abdominal aorta. Each observer was asked to measure 3 quantities; anterior-posterior AAA diameter, maximum oblique AAA diameter, maximum aneurysm area using both 2D and 3D techniques. In order to test intra-observer variability each observer was asked to repeat their measurements. All measurements were taken using electronic callipers, under standardised viewing conditions using previously calibrated equipment. 3D measurements were conducted using a computer generated central luminal line (CLL). All measurements for this group were taken perpendicular to the CLL. Results: A total of 972 independent measurements were recorded by three observers. Mean intra-observer variability was lower for 2D diameter measurements (AP 1.3 ± 1.6 mm; 2D Oblique 1.2 ± 1.3 mm) and 2D areas (0.7 ± 1.3 cm 2 ) when compared to inter-observer variability (AP 1.7 ± 1.9 mm; Oblique 1.6 ± 1.7 mm; area 1.1 ± 1.5 cm 2 ). When comparing 2D with 3D measurements, differences were comparable except for 3D AP diameter and area which had lower inter-observer variability than their 2D counterparts (AP 2D 1.7 ± 1.9 mm, 3D 1.3 ± 1.3 mm; area 2D 1.1 ± 1.5 cm 2 , 3D 0.7 ± 0.7 cm 2 ). 3D area measurement was the only technique which had equal variability for intra- and inter-observer measurements. Overall observer variability for the study was good with 94-100% of all paired measurements within 5.00 mm/cm 2 or less. Using Pitman's test it can be confirmed that area measurements in the 3D plane have the least variability (r = 0.031) and 3D oblique measurements have the highest variability (r = 0

  10. Management of Endovascular Aortic Aneurysm Complications via Retrograde Catheterization Through the Distal Stent-Graft Landing Zone.

    Science.gov (United States)

    Zhang, Xicheng; Sun, Yuan; Chen, Zhaolei; Jing, Yuanhu; Xu, Miao

    2017-08-01

    A retrograde technique through the gap between the distal stent landing zone and the iliac artery wall has been applied to treat type II endoleak after endovascular aortic aneurysm repair (EVAR). In this study, we tried to investigate its efficacy in the management of type III endoleak and intraoperative accidental events. We reported 2 complications of EVAR that were difficult to treat with conventional methods. One patient had a sustained type III endoleak after EVAR, and the right renal artery was accidentally sealed by a graft stent in the other patient during the operation. Both complications were managed by the retrograde technique from the distal stent landing zone. In the first case, the endoleak was easily embolized by the retrograde catheterization technique, and in the second case, a stent was implanted in the right renal artery using the retrograde technique to restore blood flow. In some EVAR cases, the technique of retrograde catheterization through the distal stent-graft landing zone is feasible, safe, and easy to perform.

  11. Evaluation of temporal windows for coronary artery bypass graft imaging with 64-slice CT

    International Nuclear Information System (INIS)

    Desbiolles, Lotus; Leschka, Sebastian; Scheffel, Hans; Husmann, Lars; Garzoli, Elisabeth; Marincek, Borut; Alkadhi, Hatem; Plass, Andre; Gaemperli, Oliver; Kaufmann, Philipp A.

    2007-01-01

    Temporal windows providing the best image quality of different segments and types of coronary artery bypass grafts (CABGs) with 64-slice computed tomography (CT) were evaluated in an experimental set-up. Sixty-four-slice CT with a rotation time of 330 ms was performed in 25 patients (four female; mean age 59.9 years). A total of 84 CABGs (62 individual and 22 sequential grafts) were evaluated, including 28 internal mammary artery (33.3%), one radial artery with sequential grafting (2.4%), and 54 saphenous vein grafts (64.3%). Ten data sets were reconstructed in 10% increments of the RR-interval. Each graft was separated into segments (proximal and distal anastomosis, and body), and CABG types were grouped according to target arteries. Two readers independently assessed image quality of each CABG segment in each temporal window. Diagnostic image quality was found with good inter-observer agreement (kappa=0.62) in 98.5% (202/205) of all graft segments. Image quality was significantly better for saphenous vein grafts versus arterial grafts (P<0.001) and for distal anastomosis to the right coronary compared with other target coronary arteries (P<0.05). Overall, best image quality was found at 60%. Image quality of proximal segments did not significantly vary with the temporal window, whereas for all other segments image quality was significantly better at 60% compared with other temporal windows (P<0.05). Sixty-four-slice CT provides best image quality of various segments and types of CABG at 60% of the RR-interval. (orig.)

  12. 3D-CT evaluation of secondary alveolar bone grafts in alveolar clefts

    Energy Technology Data Exchange (ETDEWEB)

    Naitoh, Hiroshi; Nishimura, Yoshihiko [Kyoto Univ. (Japan). Graduate School of Medicine; Yamawaki, Yoshiroh [Kyoto Katsura Hospital (Japan); Morimoto, Naoki [Kobe City General Hospital (Japan)

    2002-07-01

    From 1994 to 2000, we treated 116 patients with cleft alveolus by secondary alveolar bone grafts, and 48 of them were evaluated morphologically with 3D-CT. The frequency of successful bony bridging was significantly higher in the group whose grafts were completely enveloped (including the anterior alveolar ridge) with a mucoperiosteal flap. The frequency was also significantly higher in the group who underwent bone grafts at the age of 13 or less, and canine eruptions did not influence the ratio. Some cases showed such an improved growth pattern of grafted bone that the shape of the affected maxilla resembled that of the normal side, after long-term follow-up observations. The growth increment was remarkable in anterior maxillary height. Orthodontic management guides the canine or incisor into the reconstructed area of the previous cleft. We surmise that the new occlusal position puts pressure on the grafted bone and promotes further osteogenesis. These findings show that it is important to produce sufficient bony bridge to guide the canine or incisor, not the volume of grafted bone, in secondary alveolar bone grafts. Long-term follow-up observation, after more than 2-3 years, is also necessary to evaluate secondary alveolar bone grafts. (author)

  13. Cirsoid Aneurysm of Coronary Arteries Associated with Arterioventricular Fistula Evaluated by 64-Multidetector CT Coronary Angiography: Depiction of a Case

    International Nuclear Information System (INIS)

    Marrone, Gianluca; Mamone, Giuseppe; Milazzo, Mariapina; Caruso, Settimo; Baravoglia, Cesar Hernandez; Vitulo, Patrizio; Gridelli, Bruno; Luca, Angelo

    2009-01-01

    A female patient with severe pulmonary hypertension was admitted for lung transplant evaluation. As an incidental finding, the chest CT showed diffuse and dilated coronaries, not detected at previous echocardiography. A coronary CT angiography was then performed using a 64-multidetector computed tomography (MDCT) scanner to better evaluate the coronary tree. The images obtained after postprocessing demonstrated tremendously aneurysmatic and tortuous coronary arteries and the presence of a septal branch deepening into the myocardium and penetrating the right ventricle cavity, forming an abnormal arterioventricular fistula. A causal relation between the aneurysms and the fistula is suspected.

  14. Autopsy case of a giant aneurysm of the anterior communicating artery. Correlation of CT findings and angiographic findings

    Energy Technology Data Exchange (ETDEWEB)

    Shinmura, Fujio; Takayasu, Kenji; Ohiwa, Yasuyuki; Sakata, Ryuichi; Ariwa, Rokuro

    1983-06-01

    A 64-year-old female was admitted to the hospital with a history of three previous subarachnoid hemorrhages. Neurological examinations revealed incontinentia urinae, gait disturbance, recent memory disturbance and motor weakness on the left side. Plain X-ray films showed a ring-like calcification in the right frontal region. A plain CT scan showed a ring-shaped iso- and high-density area in the intra hemispheric region, the intra bilateral anterior horn of the lateral ventricle, the intra septum pellucidum, and the intra anterior part of the third ventricle. Left carotid angiography showed a large aneurysmal shadow arising from the anterior communicating artery and another from the left middle cerebral artery. In the venous phase the venous angle was supero-posteriorly shifted, and the septal vein was elevated. She died unexpectedly with a status epilepticus of unknown origin. An autopsy specimen revealed that a giant aneurysm occupied the intra ventricular space, the anterior horn of the lateral ventricle, and the right thalamic region. Also, there was a large berry aneurysm arising from the middle cerebral artery. A coronary section through the giant aneurysm showed a markedly compressed left lateral ventricle, right thalamus, and hypothalamus, while the third ventricle had shifted toward the left side.

  15. CFD Modelling of Abdominal Aortic Aneurysm on Hemodynamic Loads Using a Realistic Geometry with CT

    Directory of Open Access Journals (Sweden)

    Eduardo Soudah

    2013-01-01

    Full Text Available The objective of this study is to find a correlation between the abdominal aortic aneurysm (AAA geometric parameters, wall stress shear (WSS, abdominal flow patterns, intraluminal thrombus (ILT, and AAA arterial wall rupture using computational fluid dynamics (CFD. Real AAA 3D models were created by three-dimensional (3D reconstruction of in vivo acquired computed tomography (CT images from 5 patients. Based on 3D AAA models, high quality volume meshes were created using an optimal tetrahedral aspect ratio for the whole domain. In order to quantify the WSS and the recirculation inside the AAA, a 3D CFD using finite elements analysis was used. The CFD computation was performed assuming that the arterial wall is rigid and the blood is considered a homogeneous Newtonian fluid with a density of 1050 kg/m3 and a kinematic viscosity of 4×10-3 Pa·s. Parallelization procedures were used in order to increase the performance of the CFD calculations. A relation between AAA geometric parameters (asymmetry index (β, saccular index (γ, deformation diameter ratio (χ, and tortuosity index (ε and hemodynamic loads was observed, and it could be used as a potential predictor of AAA arterial wall rupture and potential ILT formation.

  16. Treatment of aneurysmal bone cysts by percutaneous CT-guided injection of calcitonin and steroid

    Energy Technology Data Exchange (ETDEWEB)

    Chang, Connie Y.; Kattapuram, Susan V.; Huang, Ambrose J.; Simeone, F.J.; Torriani, Martin; Bredella, Miriam A. [Massachusetts General Hospital, Department of Radiology Division of Musculoskeletal Imaging and Intervention, Boston, MA (United States)

    2017-01-15

    To determine the efficacy and safety of percutaneous calcitonin and steroid injection in the treatment of aneurysmal bone cysts (ABCs). Our study was IRB-approved and HIPAA-compliant. We reviewed pre- and post-procedural imaging studies and medical records of all CT-guided percutaneous injections of ABCs with calcitonin and steroid performed at our institution between 2003 and 2015. Treatment success based on imaging was categorized as substantial (51-100 %), partial (1-50 %), or none (0 %) by comparing radiographs of the lesion before and after treatment. Our study group comprised 9 patients (7 female, 2 male; mean age 19 ± 5 (range 12-25) years). ABCs were located in the pubis (n = 3), femur (n = 2), and humerus/scapula/ilium/sacrum (n = 1 for each). One patient did not have any clinical or imaging follow-up. For the other 8 patients, clinical and imaging follow-up ranged from 1 to 93 months (mean 16 ± 29 months). One patient had two injections, and 1 patient had three injections. Six out of eight patients (75 %) had complete symptomatic relief and 2 patients (25 %) had partial symptomatic relief after initial injection. Imaging follow-up revealed substantial imaging response in 4 out of 8 patients (50 %). There was a partial imaging response in 2 patients (25 %) and no imaging response in 2 out of 8 patients (25 %), and all 4 of these patients had local recurrence. There were no complications. Percutaneous CT-guided injection of ABCs with calcitonin and steroid is a safe and effective treatment. Lack of imaging response may necessitate more aggressive treatment to minimize local recurrence. (orig.)

  17. High prevalence of intracranial aneurysms in patients with aortic dissection or aneurysm: feasibility of extended aorta CT angiography with involvement of intracranial arteries.

    Science.gov (United States)

    Lee, Dahye; Ahn, Sung Jun; Cho, Eun-Suk; Kim, Yong Bae; Song, Suk-Won; Jung, Woo Sang; Suh, Sang Hyun

    2017-10-01

    Previous studies have suggested a higher prevalence of intracranial aneurysms (IAs) in patients with aortic aneurysms (AAs). To carry out a preliminary study to evaluate the prevalence of IAs in these patients and the diagnostic feasibility of extended aorta CT angiography (CTA), including intracranial arteries as well as the aorta. We retrospectively reviewed all patients with a clinical diagnosis of AA or aortic dissection (AD) who had undergone aorta CTA as well as MR angiography, CTA, and/or DSA of the brain between 2009 and 2014. Since 2012, the extended aorta CTA protocol has been applied in these patients. Characteristics of IAs were classified with baseline clinical data. For quantitative and qualitative assessment by two independent raters, brain images obtained by extended aorta CTA and brain CTA were compared. The radiation dose of the two aorta protocols was compared. The prevalence of IA was 22.2% (35/158). All IAs were detected by extended aorta CTA, except one small aneurysm (product of the extended aorta CTA increased with increment of the scan range (p=0.048). With a high prevalence of IAs in patients with ADs or AAs, extended aorta CTA could be used to evaluate aorta disease and IA in a single session. However, further prospective studies are needed to prove efficacy and safety of the extended aorta CTA protocol in patients with AAs or ADs. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/.

  18. High-Resolution C-Arm CT and Metal Artifact Reduction Software: A Novel Imaging Modality for Analyzing Aneurysms Treated with Stent-Assisted Coil Embolization.

    Science.gov (United States)

    Yuki, I; Kambayashi, Y; Ikemura, A; Abe, Y; Kan, I; Mohamed, A; Dahmani, C; Suzuki, T; Ishibashi, T; Takao, H; Urashima, M; Murayama, Y

    2016-02-01

    Combination of high-resolution C-arm CT and novel metal artifact reduction software may contribute to the assessment of aneurysms treated with stent-assisted coil embolization. This study aimed to evaluate the efficacy of a novel Metal Artifact Reduction prototype software combined with the currently available high spatial-resolution C-arm CT prototype implementation by using an experimental aneurysm model treated with stent-assisted coil embolization. Eight experimental aneurysms were created in 6 swine. Coil embolization of each aneurysm was performed by using a stent-assisted technique. High-resolution C-arm CT with intra-arterial contrast injection was performed immediately after the treatment. The obtained images were processed with Metal Artifact Reduction. Five neurointerventional specialists reviewed the image quality before and after Metal Artifact Reduction. Observational and quantitative analyses (via image analysis software) were performed. Every aneurysm was successfully created and treated with stent-assisted coil embolization. Before Metal Artifact Reduction, coil loops protruding through the stent lumen were not visualized due to the prominent metal artifacts produced by the coils. These became visible after Metal Artifact Reduction processing. Contrast filling in the residual aneurysm was also visualized after Metal Artifact Reduction in every aneurysm. Both the observational (P software. The combination of high-resolution C-arm CT and Metal Artifact Reduction enables differentiation of the coil mass, stent, and contrast material on the same image by significantly reducing the metal artifacts produced by the platinum coils. This novel image technique may improve the assessment of aneurysms treated with stent-assisted coil embolization. © 2016 by American Journal of Neuroradiology.

  19. CT appearances of unilateral cleft palate 20 years after bone graft surgery

    International Nuclear Information System (INIS)

    Kolbenstvedt, A.; Aaloekken, T.M.

    2002-01-01

    Purpose: To describe CT appearances in patients with unilateral cleft lip and palate (CLP) 20 years after bone graft surgery. Material and Methods: Eighteen consecutive patients with unilateral CLP were examined. All patients had been treated with primary closure, both in infancy and early childhood, supplemented with bone grafting at the age of around 10 years. The CT examination of the upper jaw included a dental CT program. The CT appearances of the cleft side were compared with those of the untreated non-cleft side. Results: Abnormal CT appearances included skew nasal aperture (n=17), nasal septal deviation (n=17), low floor of nasal aperture (n=15) at or towards the cleft side, and deviation of anterior nasal spine towards the non-cleft side (n=18). The posterior part of the bone cleft was visible in all patients, and the dental arch was V-shaped in 8. Conclusion: Although adherence to the present treatment protocol is considered to give satisfactory functional and cosmetic results, certain abnormalities persist. A knowledge of these is a prerequisite for a complete and final evaluation of the surgical and orthodontic regimen. Cleft palate nasal cavity abnormalities CT

  20. CT appearances of unilateral cleft palate 20 years after bone graft surgery

    Energy Technology Data Exchange (ETDEWEB)

    Kolbenstvedt, A.; Aaloekken, T.M. [Rikshospitalet, Oslo (Norway). Dept. of Radiology; Arctander, K. [Rikshospitalet, Oslo (Norway). Dept. of Plastic Surgery; Johannessen, S. [Inst. of Clinical Dentistry, Oslo (Norway)

    2002-11-01

    Purpose: To describe CT appearances in patients with unilateral cleft lip and palate (CLP) 20 years after bone graft surgery. Material and Methods: Eighteen consecutive patients with unilateral CLP were examined. All patients had been treated with primary closure, both in infancy and early childhood, supplemented with bone grafting at the age of around 10 years. The CT examination of the upper jaw included a dental CT program. The CT appearances of the cleft side were compared with those of the untreated non-cleft side. Results: Abnormal CT appearances included skew nasal aperture (n=17), nasal septal deviation (n=17), low floor of nasal aperture (n=15) at or towards the cleft side, and deviation of anterior nasal spine towards the non-cleft side (n=18). The posterior part of the bone cleft was visible in all patients, and the dental arch was V-shaped in 8. Conclusion: Although adherence to the present treatment protocol is considered to give satisfactory functional and cosmetic results, certain abnormalities persist. A knowledge of these is a prerequisite for a complete and final evaluation of the surgical and orthodontic regimen. Cleft palate nasal cavity abnormalities CT.

  1. Detection of intracranial aneurysms using three-dimensional multidetector-row CT angiography: Is bone subtraction necessary?

    International Nuclear Information System (INIS)

    Hwang, Seung Bae; Kwak, Hyo Sung; Han, Young Min; Chung, Gyung Ho

    2011-01-01

    Purpose: The aim of this study was to evaluate the usefulness of three-dimensional CT angiography (3D CTA) with bone subtraction in a comparison with 3D CTA without bone subtraction for the detection of intracranial aneurysms. Materials and methods: Among 337 consecutive patients who had intracranial aneurysms detected on 3D CTA, 170 patients who underwent digital subtraction angiography (DSA) were included in the study. CTA was performed with a 16-slice multidetector-row CT (MDCT) scanner. We created the 3D reconstruction images with and without bone subtraction by using the volume rendering technique. Three neuroradiologists in a blinded fashion interpreted both 3D CTA images with and without bone subtraction. The diagnostic accuracy of both techniques was evaluated using the alternative free-response receiver operating characteristic (ROC) analysis. The sensitivity and positive predictive value were also evaluated. Results: A total of 200 aneurysms (size: 2-23 mm) were detected in 170 patients. The area under the receiver operating characteristic curve (Az) for 3D CTA with bone subtraction (mean, Az = 0.933) was significantly higher than that for 3D CTA without bone subtraction (mean, Az = 0.879) for all observers (P < 0.05). The sensitivity of 3D CTA with bone subtraction for three observers was 90.0, 92.0 and 92.5%, respectively, while the sensitivity of 3D CTA without bone subtraction was 83.5, 83.5 and 87.5%, respectively. No significant difference in positive predictive value was observed between the two modalities. Conclusions: 3D CTA with bone subtraction showed significantly higher diagnostic accuracy for the detection of intracranial aneurysms as compared to 3D CTA without bone subtraction.

  2. Different CT perfusion algorithms in the detection of delayed cerebral ischemia after aneurysmal subarachnoid hemorrhage.

    Science.gov (United States)

    Cremers, Charlotte H P; Dankbaar, Jan Willem; Vergouwen, Mervyn D I; Vos, Pieter C; Bennink, Edwin; Rinkel, Gabriel J E; Velthuis, Birgitta K; van der Schaaf, Irene C

    2015-05-01

    Tracer delay-sensitive perfusion algorithms in CT perfusion (CTP) result in an overestimation of the extent of ischemia in thromboembolic stroke. In diagnosing delayed cerebral ischemia (DCI) after aneurysmal subarachnoid hemorrhage (aSAH), delayed arrival of contrast due to vasospasm may also overestimate the extent of ischemia. We investigated the diagnostic accuracy of tracer delay-sensitive and tracer delay-insensitive algorithms for detecting DCI. From a prospectively collected series of aSAH patients admitted between 2007-2011, we included patients with any clinical deterioration other than rebleeding within 21 days after SAH who underwent NCCT/CTP/CTA imaging. Causes of clinical deterioration were categorized into DCI and no DCI. CTP maps were calculated with tracer delay-sensitive and tracer delay-insensitive algorithms and were visually assessed for the presence of perfusion deficits by two independent observers with different levels of experience. The diagnostic value of both algorithms was calculated for both observers. Seventy-one patients were included. For the experienced observer, the positive predictive values (PPVs) were 0.67 for the delay-sensitive and 0.66 for the delay-insensitive algorithm, and the negative predictive values (NPVs) were 0.73 and 0.74. For the less experienced observer, PPVs were 0.60 for both algorithms, and NPVs were 0.66 for the delay-sensitive and 0.63 for the delay-insensitive algorithm. Test characteristics are comparable for tracer delay-sensitive and tracer delay-insensitive algorithms for the visual assessment of CTP in diagnosing DCI. This indicates that both algorithms can be used for this purpose.

  3. Polar orientation of renal grafts within the proximal seal zone affects risk of early type IA endoleaks after chimney endovascular aneurysm repair.

    Science.gov (United States)

    Tran, Kenneth; Ullery, Brant W; Itoga, Nathan; Lee, Jason T

    2018-04-01

    The objective of this study was to describe the polar orientation of renal chimney grafts within the proximal seal zone and to determine whether graft orientation is associated with early type IA endoleak or renal graft compression after chimney endovascular aneurysm repair (ch-EVAR). Patients who underwent ch-EVAR with at least one renal chimney graft from 2009 to 2015 were included in this analysis. Centerline three-dimensional reconstructions were used to analyze postoperative computed tomography scans. The 12-o'clock polar position was set at the takeoff of the superior mesenteric artery. Relative polar positions of chimney grafts were recorded at the level of the renal artery ostium, at the mid-seal zone, and at the proximal edge of the graft fabric. Early type IA endoleaks were defined as evidence of a perigraft flow channel within the proximal seal zone. There were 62 consecutive patients who underwent ch-EVAR (35 double renal, 27 single renal) for juxtarenal abdominal aortic aneurysms with a mean follow-up of 31.2 months; 18 (29%) early type IA "gutter" endoleaks were identified. During follow-up, the majority of these (n = 13; 72%) resolved without intervention, whereas two patients required reintervention (3.3%). Estimated renal graft patency was 88.9% at 60 months. Left renal chimney grafts were most commonly at the 3-o'clock position (51.1%) at the ostium, traversing posteriorly to the 5- to 7-o'clock positions (55.5%) at the fabric edge. Right renal chimney grafts started most commonly at the 9-o'clock position (n = 17; 33.3%) and tended to traverse both anteriorly (11 to 1 o'clock; 39.2%) and posteriorly (5 to 7 o'clock; 29.4%) at the fabric edge. In the polar plane, the majority of renal chimney grafts (n = 83; 85.6%) traversed 90 degrees were independently associated with early type IA endoleaks (odds ratio, 11.5; 95% confidence interval, 2.1-64.8) even after controlling for other device and anatomic variables. Polar orientation of the chimney

  4. Evaluation of occurring complications after flow diverter treatment of elastase-induced aneurysm in rabbits using micro-CT and MRI at 9.4 T

    Energy Technology Data Exchange (ETDEWEB)

    Simgen, Andreas; Ley, Desiree; Muehl-Benninghaus, Ruben; Koerner, Heiko; Reith, Wolfgang; Yilmaz, Umut [Saarland University Hospital, Department of Neuroradiology, Homburg, Saar (Germany); Roth, Christian [Clinic Bremen-Mitte, Department of Neuroradiology, Bremen (Germany); Cattaneo, Giorgio Franco Maria [Acandis GmbH, Pforzheim (Germany); Mueller, Andreas [Saarland University Hospital, Department of Experimental Surgery, Homburg, Saar (Germany); Kim, Yoo-Jin [Saarland University Hospital, Department of Pathology, Homburg, Saar (Germany); Scheller, Bruno [Saarland University Hospital, Department of Cardiology, Homburg, Saar (Germany)

    2016-10-15

    Flow diverters are increasingly being used to treat intracranial aneurysms. This study evaluates occurring complications of flow-diverting devices in the treatment of experimental aneurysms, involving the use of micro-CT and small animal MRI at 9.4 T, in correlation to angiographic and histological findings. We previously published two preclinical studies, in which we assessed two different flow diverters in the treatment of elastase-induced aneurysms. Devices have been implanted across the aneurysm neck as well as in the abdominal aorta. From these studies, a total of 65 devices (prototype FD (n = 30) and Derivo embolization device (n = 35)) additionally underwent micro-CT and MRI after angiographic follow-up and before being histologically examined. The different architectures of both devices were precisely comparable due to high-resolution micro-CT imaging. Micro-CT revealed wire fractures in nine cases (30 %) only with the prototype FD. In three cases (10 %), severe wire fractures correlated with an in-stent stenosis due to intimal hyperplasia. Other complications, like distal stent occlusions and post-stent stenosis, were seen in both groups and verified with both imaging techniques. Osseous metaplasia were correlated to calcifications seen with micro-CT. MRI enabled visualization of the position of the implanted devices relative to the aneurysm and revealed incomplete aneurysm neck coverage with the prototype FD in two cases (6.7 %). Micro-CT and 9.4-T MRI are valid to discover and understand occurring complications of flow diverters in the preclinical phase and can serve as evaluation tools to minimize complication rates of endovascular devices in the future. (orig.)

  5. 3D printed abdominal aortic aneurysm phantom for image guided surgical planning with a patient specific fenestrated endovascular graft system

    Science.gov (United States)

    Meess, Karen M.; Izzo, Richard L.; Dryjski, Maciej L.; Curl, Richard E.; Harris, Linda M.; Springer, Michael; Siddiqui, Adnan H.; Rudin, Stephen; Ionita, Ciprian N.

    2017-03-01

    Following new trends in precision medicine, Juxatarenal Abdominal Aortic Aneurysm (JAAA) treatment has been enabled by using patient-specific fenestrated endovascular grafts. The X-ray guided procedure requires precise orientation of multiple modular endografts within the arteries confirmed via radiopaque markers. Patient-specific 3D printed phantoms could familiarize physicians with complex procedures and new devices in a risk-free simulation environment to avoid periprocedural complications and improve training. Using the Vascular Modeling Toolkit (VMTK), 3D Data from a CTA imaging of a patient scheduled for Fenestrated EndoVascular Aortic Repair (FEVAR) was segmented to isolate the aortic lumen, thrombus, and calcifications. A stereolithographic mesh (STL) was generated and then modified in Autodesk MeshMixer for fabrication via a Stratasys Eden 260 printer in a flexible photopolymer to simulate arterial compliance. Fluoroscopic guided simulation of the patient-specific FEVAR procedure was performed by interventionists using all demonstration endografts and accessory devices. Analysis compared treatment strategy between the planned procedure, the simulation procedure, and the patient procedure using a derived scoring scheme. Results: With training on the patient-specific 3D printed AAA phantom, the clinical team optimized their procedural strategy. Anatomical landmarks and all devices were visible under x-ray during the simulation mimicking the clinical environment. The actual patient procedure went without complications. Conclusions: With advances in 3D printing, fabrication of patient specific AAA phantoms is possible. Simulation with 3D printed phantoms shows potential to inform clinical interventional procedures in addition to CTA diagnostic imaging.

  6. Preoperative evaluation of the artery of adamkiewicz by MR angiography and CT angiography in patients with a thoracic aortic aneurysm

    International Nuclear Information System (INIS)

    Niinuma, Hiroyuki; Ohira, Atsushi; Makita, Shinji; Moriai, Yoshiteru; Hiramori, Katsuhiko; Yoshioka, Kunihiro; Nakajima, Takayuki; Kawazoe, Kohei

    2002-01-01

    Paraplegia is known as an extremely serious and important complication of surgical repair in patients with a thoraco-abdominal aortic aneurysm. It is important to evaluate the artery of Adamkiewicz (AdA) before surgical repair to prevent paraplegia. But the AdA is difficult to visualize by the invasive and hazardous, conventional selective angiography. The aim of this study was to visualize AdA by MR angiography (MRA) and CT angiography (CTA). Twenty-one consecutive patients with a thoracic aortic aneurysm underwent both gadolinium-enhanced, three-dimensional MRA and CTA using multislice helical CT. The AdA was successfully visualized in 15 of the 21 patients (71.4%) by MRA, and in 17 of those 21 patients (80.9%) by CTA. Its continuity was depicted in 12 of 15 patients (80%) by MRA, and in 9 of 17 patients (47%) by CTA. AdA was visualized at 85.7% by MRA or CTA, respectively. This study shows that CTA is a much more sensitive method to detect AdA than MRA. On the other hand, MRA is better to evaluate the continuity of AdA from the descending aorta to the anterior spinal artery, than CTA. Therefore, MRA and CTA are both useful for a preoperative evaluation of AdA and its detailed vascular anatomy from the aorta to the anterior spinal artery. (author)

  7. Accuracy of FDG-PET-CT in the Diagnostic Work-up of Vascular Prosthetic Graft Infection

    NARCIS (Netherlands)

    Bruggink, J. L. M.; Glaudemans, A. W. J. M.; Saleem, B. R.; Meerwaldt, R.; Alkefaji, H.; Prins, T. R.; Start, R. H. J. A.; Zeebregts, C. J.

    Objectives: To investigate the diagnostic accuracy of fluoro-2-deoxy-D-glucose positron emission tomography (FDG-PET) compared with computed tomography (CT) scanning and added value of fused FDG-PET CT in diagnosing vascular prosthetic graft infection. Design: Prospective cohort study with

  8. Follow-up CT and CT angiography after intracranial aneurysm clipping and coiling - improved image quality by iterative metal artifact reduction

    Energy Technology Data Exchange (ETDEWEB)

    Bier, Georg; Hempel, Johann-Martin; Oergel, Anja; Hauser, Till-Karsten; Ernemann, Ulrike; Hennersdorf, Florian [Eberhard Karls University Tuebingen, Department of Diagnostic and Interventional Neuroradiology, Tuebingen (Germany); Bongers, Malte Niklas [Eberhard Karls University Tuebingen, Department of Diagnostic and Interventional Radiology, Tuebingen (Germany)

    2017-07-15

    This paper aims to evaluate a new iterative metal artifact reduction algorithm for post-interventional evaluation of brain tissue and intracranial arteries. The data of 20 patients that underwent follow-up cranial CT and cranial CT angiography after clipping or coiling of an intracranial aneurysm was retrospectively analyzed. After the images were processed using a novel iterative metal artifact reduction algorithm, images with and without metal artifact reduction were qualitatively evaluated by two readers, using a five-point Likert scale. Moreover, artifact strength was quantitatively assessed in terms of CT attenuation and standard deviation alterations. The qualitative analysis yielded a significant increase in image quality (p = 0.0057) in iteratively processed images with substantial inter-observer agreement (k = 0.72), while the CTA image quality did not differ (p = 0.864) and even showed vessel contrast reduction in six cases (30%). The mean relative attenuation difference was 27% without metal artifact reduction vs. 11% for iterative metal artifact reduction images (p = 0.0003). The new iterative metal artifact reduction algorithm enhances non-enhanced CT image quality after clipping or coiling, but in CT-angiography images, the contrast of adjacent vessels can be compromised. (orig.)

  9. Follow-up CT and CT angiography after intracranial aneurysm clipping and coiling - improved image quality by iterative metal artifact reduction

    International Nuclear Information System (INIS)

    Bier, Georg; Hempel, Johann-Martin; Oergel, Anja; Hauser, Till-Karsten; Ernemann, Ulrike; Hennersdorf, Florian; Bongers, Malte Niklas

    2017-01-01

    This paper aims to evaluate a new iterative metal artifact reduction algorithm for post-interventional evaluation of brain tissue and intracranial arteries. The data of 20 patients that underwent follow-up cranial CT and cranial CT angiography after clipping or coiling of an intracranial aneurysm was retrospectively analyzed. After the images were processed using a novel iterative metal artifact reduction algorithm, images with and without metal artifact reduction were qualitatively evaluated by two readers, using a five-point Likert scale. Moreover, artifact strength was quantitatively assessed in terms of CT attenuation and standard deviation alterations. The qualitative analysis yielded a significant increase in image quality (p = 0.0057) in iteratively processed images with substantial inter-observer agreement (k = 0.72), while the CTA image quality did not differ (p = 0.864) and even showed vessel contrast reduction in six cases (30%). The mean relative attenuation difference was 27% without metal artifact reduction vs. 11% for iterative metal artifact reduction images (p = 0.0003). The new iterative metal artifact reduction algorithm enhances non-enhanced CT image quality after clipping or coiling, but in CT-angiography images, the contrast of adjacent vessels can be compromised. (orig.)

  10. 18F-Fluorodeoxyglucose Positron Emission Tomography/CT Scanning in Diagnosing Vascular Prosthetic Graft Infection

    Science.gov (United States)

    Saleem, Ben R.; Pol, Robert A.; Slart, Riemer H. J. A.; Reijnen, Michel M. P. J.; Zeebregts, Clark J.

    2014-01-01

    Vascular prosthetic graft infection (VPGI) is a severe complication after vascular surgery. CT-scan is considered the diagnostic tool of choice in advanced VPGI. The incidence of a false-negative result using CT is relatively high, especially in the presence of low-grade infections. 18F-fluorodeoxyglucose positron emission tomography (18F-FDG PET) scanning has been suggested as an alternative for the diagnosis and assessment of infectious processes. Hybrid 18F-FDG PET/CT has established the role of 18F-FDG PET for the assessment of suspected VPGI, providing accurate anatomic localization of the site of infection. However, there are no clear guidelines for the interpretation of the uptake patterns of 18F-FDG as clinical tool for VPGI. Based on the available literature it is suggested that a linear, diffuse, and homogeneous uptake should not be regarded as an infection whereas focal or heterogeneous uptake with a projection over the vessel on CT is highly suggestive of infection. Nevertheless, 18F-FDG PET and 18F-FDG PET/CT can play an important role in the detection of VPGI and monitoring response to treatment. However an accurate uptake and pattern recognition is warranted and cut-off uptake values and patterns need to be standardized before considering the technique to be the new standard. PMID:25210712

  11. Sac Angiography and Glue Embolization in Emergency Endovascular Aneurysm Repair for Ruptured Abdominal Aortic Aneurysm

    Energy Technology Data Exchange (ETDEWEB)

    Koike, Yuya, E-mail: r06118@hotmail.co.jp; Nishimura, Jun-ichi, E-mail: jun-ichi-n@nifty.com; Hase, Soichiro, E-mail: haseman@hotmail.co.jp; Yamasaki, Motoshige, E-mail: genyamasaki@gmail.com [Kawasaki Saiwai Hospital, Department of Interventional Radiology (Japan)

    2015-04-15

    PurposeThe purpose of this study was to demonstrate a sac angiography technique and evaluate the feasibility of N-butyl cyanoacrylate (NBCA) embolization of the ruptured abdominal aortic aneurysm (AAA) sac in emergency endovascular aneurysm repair (EVAR) in hemodynamically unstable patients.MethodsA retrospective case series of three patients in whom sac angiography was performed during emergency EVAR for ruptured AAA was reviewed. After stent graft deployment, angiography within the sac of aneurysm (sac angiography) was performed by manually injecting 10 ml of contrast material through a catheter to identify the presence and site of active bleeding. In two patients, sac angiography revealed active extravasation of the contrast material, and NBCA embolization with a coaxial catheter system was performed to achieve prompt sealing.ResultsSac angiography was successful in all three patients. In the two patients who underwent NBCA embolization for aneurysm sac bleeding, follow-up computed tomography (CT) images demonstrated the accumulation of NBCA consistent with the bleeding site in preprocedural CT images.ConclusionsEVAR is associated with a potential risk of ongoing bleeding from type II or IV endoleaks into the disrupted aneurysm sac in patients with severe coagulopathy. Therefore, sac angiography and NBCA embolization during emergency EVAR may represent a possible technical improvement in the treatment of ruptured AAA in hemodynamically unstable patients.

  12. Endovascular Aneurysm Repair of Acute Occlusion of Abdominal Aortic Aneurysm with Intra-Aneurysmal Dissection.

    Science.gov (United States)

    Terai, Yasuhiko; Mitsuoka, Hiroshi; Nakai, Masanao; Goto, Shinnosuke; Miyano, Yuta; Tsuchiya, Hirokazu; Yamazaki, Fumio

    2015-11-01

    To report a rare case of acute abdominal aortic aneurysm (AAA) occlusion successfully treated by endovascular aneurysm repair (EVAR). An 89-year-old man complained of severe back pain and weakness in the bilateral lower extremities. Although there were neither acute ischemic signs on the brain computed tomography (CT) nor critical leg ischemia, the patient presented progressing weakness in the bilateral lower extremities and decreased sensation in the perianal and saddle area. Contrast-enhanced CT demonstrated an infrarenal AAA, the formation of an ulcer-like lesion in the aneurysmal wall, and the complete occlusion of distal AAA because of the caudal extension of intramural hematoma. Both common iliac arteries were patent because of the development of collateral vessels. The neurologic symptoms were considered to be caused by the occlusion of lumbar radicular arteries. EVAR seemed anatomically feasible, if the occlusion could be crossed by guidewires from both side of the common femoral artery. Wires easily traversed the occlusion, and the stent graft could be smoothly unwrapped and opened. The patient could recover decent iliac arterial flow. The neurovascular deficits recovered within 4 days after the procedure. Although our experience may not be reproduced in all case of AAA occlusion, EVAR warrants consideration to reduce the high mortality rate associated with the classical treatments. Copyright © 2015 Elsevier Inc. All rights reserved.

  13. Grafting

    Energy Technology Data Exchange (ETDEWEB)

    Garnett, J L [New South Wales Univ., Kensington (Australia). School of Chemistry

    1979-01-01

    The unique value of ionizing radiation for the initiation of grafting to backbone polymers is discussed. The principles of the technique are briefly reviewed. The conditions under which free radicals and ions participate in these reactions are examined. Examples of representative grafting processes are considered to illustrate where the technique can be of potential commercial value to a wide range of industries. The general principles of these grafting reactions are shown to be applicable to radiation induced rapid cure technology such as is provided by electron beam processing facilities. Grafting reactions initiated by UV are also treated and shown to be of importance because of the many similarities in properties of the ionizing radiation and UV systems, also the rapid industrial exploitation of EB and sensitized UV processing technology. Possible future trends in radiation grafting are outlined.

  14. Value of Perfusion CT, Transcranial Doppler Sonography, and Neurological Examination to Detect Delayed Vasospasm after Aneurysmal Subarachnoid Hemorrhage

    International Nuclear Information System (INIS)

    Kunze, E.; Raslan, F.; Stetter, Ch.; Lee, J.Y.; Solymosi, L.; Ernestus, R.I.; Vince, G.H.; Westermaier, Th.; Pham, M.; Solymosi, L.

    2012-01-01

    Background. If detected in time, delayed cerebral vasospasm after aneurysmal subarachnoid hemorrhage (SAH) may be treated by balloon angioplasty or chemical vasospasmolysis in order to enhance cerebral blood flow (CBF) and protect the brain from ischemic damage. This study was conceived to compare the diagnostic accuracy of detailed neurological examination, Transcranial Doppler Sonography (TCD), and Perfusion-CT (PCT) to detect angiographic vasospasm. Methods. The sensitivity, specificity, positive and negative predictive values of delayed ischemic neurological deterioration (DIND), pathological findings on PCT-maps, and accelerations of the mean flow velocity (MVF) were calculated. Results. The accuracy of DIND to predict angiographic vasospasm was 0.88. An acceleration of MFV in TCD (>140 cm/s) had an accuracy of 0.64, positive PCT-findings of 0.69 with a higher sensitivity, and negative predictive value than TCD. Interpretation. Neurological assessment at close intervals is the most sensitive and specific parameter for cerebral vasospasm. PCT has a higher accuracy, sensitivity and negative predictive value than TCD. If detailed neurological evaluation is possible, it should be the leading parameter in the management and treatment decisions. If patients are not amenable to detailed neurological examination, PCT at regular intervals is a helpful tool to diagnose secondary vasospasm after aneurysmal SAH

  15. Can Surgeons Assess CT Suitability for Endovascular Repair (EVAR) in Ruptured Abdominal Aortic Aneurysm? Implications for a Ruptured EVAR Trial

    International Nuclear Information System (INIS)

    Rayt, Harjeet; Lambert, Kelly; Bown, Matthew; Fishwick, Guy; Morgan, Robert; McCarthy, Mark; London, Nick; Sayers, Robert

    2008-01-01

    The purpose of this study was to determine whether surgeons without formal radiological training are able to assess suitability of patients with ruptured abdominal aortic aneurysms (AAA) for EVAR. The CT scans of 20 patients with AAA were reviewed under timed conditions by six vascular surgeons. Twenty minutes was allocated per scan. They were asked to determine if each aneurysm would be treatable by EVAR in the emergency setting and, if so, to measure for device selection. The results were then compared with those of a vascular radiologist. Six surgeons agreed on the suitability of endovascular repair in 45% of cases (95% CI, 23.1-68.5%; 9/20 scans; κ = 0.41 [p = 0.01]) and concurred with the radiologist in eight of these. Individually, agreement ranged from 13 to 16 of the 20 scans, 65-80% between surgeons. The kappa value for agreement between all the surgeons and the radiologist was 0.47 (p = 0.01, moderate agreement). For the individual surgeons, this ranged from 0.3 to 0.6 (p = 0.01). In conclusion, while overall agreement was moderate between the surgeons and the radiologist, it is clear that if surgeons are to assess patients for ruptured EVAR in the future, focused training of surgical trainees is required.

  16. Arch translocation and the intra-arch elephant-trunk technique with collared graft for extended chronic dissecting aortic aneurysm

    Directory of Open Access Journals (Sweden)

    Ikenaga Shigeru

    2013-01-01

    Full Text Available Abstract Management of extensive, chronic, dissecting aortic aneurysms after prior repair of the ascending aorta presents a technical challenge for surgeons. A symptomatic 64-year-old patient was admitted for elective surgical repair of an aortic annular dilatation, causing severe aortic regurgitation, and a Crawford type II extended thoracoabdominal aneurysm, 4 years after he underwent primary repair of an acute aortic dissection. The aorta was diffusely dilated, and there were no sites beyond the distal aortic arch where anastomosis could be performed. We successfully performed total aortic replacement with a 2-stage strategy, using an arch translocation technique and an intra-arch elephant-trunk technique.

  17. Dual-energy CT for detection of endoleaks after endovascular abdominal aneurysm repair: usefulness of colored iodine overlay.

    Science.gov (United States)

    Ascenti, Giorgio; Mazziotti, Silvio; Lamberto, Salvatore; Bottari, Antonio; Caloggero, Simona; Racchiusa, Sergio; Mileto, Achille; Scribano, Emanuele

    2011-06-01

    The purpose of our study was to evaluate the value of dual-source dual-energy CT with colored iodine overlay for detection of endoleaks after endovascular abdominal aortic aneurysm repair. We also calculated the potential dose reduction by using a dual-energy CT single-phase protocol. From November 2007 to November 2009, 74 patients underwent CT angiography 2-7 days after endovascular repair during single-energy unenhanced and dual-energy venous phases. By using dual-energy software, the iodine overlay was superimposed on venous phase images with different percentages ranging between 0 (virtual unenhanced images) and 50-75% to show the iodine in an orange color. Two blinded readers evaluated the data for diagnosis of endoleaks during standard unenhanced and venous phase images (session 1, standard of reference) and virtual unenhanced and venous phase images with colored iodine overlay images (session 2). We compared the effective dose radiation of a single-energy biphasic protocol with that of a single-phase dual-energy protocol. The diagnostic accuracy of session 2 was calculated. The mean dual-energy effective dose was 7.27 mSv. By using a dual-energy single-phase protocol, we obtained a mean dose reduction of 28% with respect to a single-energy biphasic protocol. The diagnostic accuracy of session 2 was: 100% sensitivity, 100% specificity, 100% negative predictive value, and 100% positive predictive value. Statistically significant differences in the level of confidence for endoleak detection between the two sessions were found by reviewers for scores 3-5. Dual-energy CT with colored iodine overlay is a useful diagnostic tool in endoleak detection. The use of a dual-energy single-phase study protocol will lower radiation exposure to patients.

  18. Giant serpentine intracranial aneurysm: a case report

    International Nuclear Information System (INIS)

    Park, Jae Seong; Lee, Myeong Sub; Kim, Myung Soon; Kim, Dong Jin; Park, Joong Wha; Whang, Kum

    2001-01-01

    The authors present a case of giant serpentine aneurysm (a partially thrombosed aneurysm containing tortuous vascular channels with a separate entrance and outflow pathway). Giant serpentine aneurysms form a subgroup of giant intracranial aneurysms, distinct from saccular and fusiform varieties, and in this case, too, the clinical presentation and radiographic features of CT, MR imaging and angiography were distinct

  19. Concepts to optimize stent-grafting of abdominal aortic aneurysms based on results of experimental studies; Konzepte zur Optimierung der Stentgraftversorgung von Bauchaortenaneurysmen auf der Basis tierexperimenteller Ergebnisse

    Energy Technology Data Exchange (ETDEWEB)

    Chavan, A.; Kirchhoff, T.; Baus, S.; Galanski, M. [Medizinische Hochschule Hannover (Germany). Abt. Diagnostische Radiologie 1; Pichlmaier, M. [Medizinische Hochschule Hannover (Germany). Leibniz Forschungslab. fuer Biotechnologie und Kuenstliche Organe an der Klinik fuer Thorax-, Herz- und Gefaesschirurgie

    2001-08-01

    Purpose. In the endoluminal therapy of abdominal aortic aneurysms, a short proximal aneurysm neck, endoleaks and the large size and stiffness of the introducer systems are responsible for many of the complications and sub-optimal outcomes. The purpose of the present review article is to to suggest strategies to minimize these complications based on the results of experimental studies in animals. Material and methods. After implanting various types of stents across the renal artery origins, the functional and morphological changes in the kidneys and renal vessels were studied by various authors. In order to prevent progressive widening of the proximal aneurysmal neck and graft dislocation, Sonesson et al. performed a laparoscopic banding around the proximal neck in pigs. To study the effects of endoleaks, Marty, Schurink and Pitton carried out pressure measurements in experimental aneurysms with and without endoleaks. Sakaguchi and Pavcnik developed the 'Twin-tube endografts' (TTEG) and the 'Bifurcated drum occluder endografts' (BDOEG) and tested them in dogs. Results. Up to 3 months after suprarenal stent placement, Chavan et al. detected no significant fall in the mean inulin clearance in sheep (140{+-}46 ml/min before, 137{+-}58 ml/min after). Nasim et al. and Malina et al. reported similar observations with respect to renal function. Suprarenal fixation may result in isolated thrombotic occlusions of the renal arteries and microinfarcts in the kidneys. Mean aortic diameters at the level of banding were significantly smaller in the animals with aortic banding as opposed to those in the control group without banding (8 mm vs 11 mm, p=0.004). The banding caused a secure proximal fixation of the stent-graft. Persistent endoleaks resulted in significantly higher intraaneurysmal pressures. Although the TTEG and the BDOEG stent-grafts required smaller sheaths, occlusions were observed in 8% (TTEG) and 60% (BDOEG) of the graft limbs. (orig.) [German

  20. The study of two methods for high pressure injection in CT enhancement to display the aortic dissecting aneurysm

    International Nuclear Information System (INIS)

    Wang Yang; Zhu Bin; Zhang Zhen

    2008-01-01

    Objective: To discuss the consequences of two different methods of high pressure injection in CT contrast enhancement to display the aortic dissecting aneurysm. Methods: 100 patients underwent Lightspeed 16 MS CT with contrast enhancement of Stellant D high pressure injector (Medrad), injecting speed of 4.0 mL/s and 80 ml dosage of contrast medium. All patients were divided into A and B groups with 50 in each. The single high pressure injection was applied to A group without isotonic Na chloride flush. B group underwent the same high pressure injection and followed by isotonic Na chloride flush. The method of evaluation was carried out by double blind observation. Results: A group revealed radiologic artifact up to 40 cases with positive rate of 80%. B group demonstrated the same kind of radiologic artifact in 26 cases with positive rate of 52%. Conclusions: Using normal saline (sodium chloride solution)flush after high pressure injection of contrast medium during MSCT angiography is obviously better to demonstrate the internal structures of treatvessels. (authors)

  1. 3D printing of an aortic aneurysm to facilitate decision making and device selection for endovascular aneurysm repair in complex neck anatomy.

    Science.gov (United States)

    Tam, Matthew D B S; Laycock, Stephen D; Brown, James R I; Jakeways, Matthew

    2013-12-01

    To describe rapid prototyping or 3-dimensional (3D) printing of aneurysms with complex neck anatomy to facilitate endovascular aneurysm repair (EVAR). A 75-year-old man had a 6.6-cm infrarenal aortic aneurysm that appeared on computed tomographic angiography to have a sharp neck angulation of ~90°. However, although the computed tomography (CT) data were analyzed using centerline of flow, the true neck length and relations of the ostial origins were difficult to determine. No multidisciplinary consensus could be reached as to which stent-graft to use owing to these borderline features of the neck anatomy. Based on past experience with rapid prototyping technology, a decision was taken to print a model of the aneurysm to aid in visualization of the neck anatomy. The CT data were segmented, processed, and converted into a stereolithographic format representing the lumen as a 3D volume, from which a full-sized replica was printed within 24 hours. The model demonstrated that the neck was adequate for stent-graft repair using the Aorfix device. Rapid prototyping of aortic aneurysms is feasible and can aid decision making and device delivery. Further work is required to test the value of 3D replicas in planning procedures and their impact on procedure time, radiation dose, and procedure cost.

  2. CT angiography for one-year follow-up of intracranial aneurysms treated with the WEB device: Utility in evaluating aneurysm occlusion and WEB compression at one year.

    Science.gov (United States)

    Raoult, Hélène; Eugène, François; Le Bras, Anthony; Mineur, Géraldine; Carsin-Nicol, Béatrice; Ferré, Jean-Christophe; Gauvrit, Jean-Yves

    2018-03-07

    The WEB is an innovative flow disruption device for cerebral aneurysm embolization with rapidly expanding indications. Our purpose was to evaluate the diagnostic performance of computed tomography angiography (CTA) at 1-year follow-up of aneurysms treated with the WEB. Between April 2014 and May 2016, the study prospectively included patients treated with the WEB at our institution, and followed up within 24hours by CTA and at 1year by CTA, time-of-flight magnetic resonance angiography (TOF MRA) and digital subtraction angiography (DSA). The diagnostic quality of imaging data was assessed based on the confidence index, artifacts, and WEB shape depiction. The imaging diagnostic performance was assessed using 3 criteria at 1year: aneurysm occlusion status and worsening, and WEB shape compression. Interobserver and intermodality agreement was determined by calculating κ values. The study ultimately included 16 patients (9 women, mean age 53±7.6years). CTA quality confidence was scored as 2/2, artifacts 0.4/2 and WEB shape depiction 1.9/2, superior to TOF MRA for the latter two criteria. Aneurysm occlusion was adequate in 93.7% of patients, with CTA showing excellent interobserver reproducibility and agreement with DSA on a 4-grade scale (κ=1.00), while TOF MRA yielded good reproducibility (κ=0.76) and agreement with DSA (κ=0.69). CTA also identified aneurysm occlusion worsening (43.7%) and WEB compression (81.2%) in excellent agreement with DSA (κ=0.85 and 1.00). CTA is a reproducible and reliable technique for the follow-up of aneurysms treated with the WEB device. Copyright © 2018 Elsevier Masson SAS. All rights reserved.

  3. Multiple giant coronary aneurysms arising from coronary istula to the pulmonary artery revealed in aorta CT angiography

    Energy Technology Data Exchange (ETDEWEB)

    Kang, Eun Ju; Lee, Ki Nam [Dept. of Radiology, Dong A University Hospital, Dong-A University College of Medicine, Busan (Korea, Republic of); Lee, Jong Min [Dept. of Radiology, Kyungpook National University Hospital, Kyungpook National University College of Medicine, Daegu (Korea, Republic of)

    2015-12-15

    Coronary fistula is a rare coronary abnormality through which blood drains into the cardiac chamber, great vessel or other vessels. In addition, giant aneurysm arising from coronary fistula is rare pathologic manifestation. Herein, we presented a rare case of multiple giant coronary artery aneurysms arising from coronary to pulmonary artery fistula in a 79-year-old woman presenting with sudden loss of consciousness. The aneurysms were detected using thoracic computed tomography angiography and consequently confirmed by invasive coronary angiography.

  4. Non-contrast 3D black blood MRI for abdominal aortic aneurysm surveillance: comparison with CT angiography

    Energy Technology Data Exchange (ETDEWEB)

    Zhu, Chengcheng; Leach, Joseph R.; Hope, Michael D. [University of California San Francisco, Department of Radiology and Biomedical Imaging, San Francisco, CA (United States); Tian, Bing; Liu, Qi; Lu, Jianping; Chen, Luguang [Changhai Hospital, Department of Radiology, Shanghai (China); Saloner, David [University of California San Francisco, Department of Radiology and Biomedical Imaging, San Francisco, CA (United States); Radiology Service, VA Medical Center, San Francisco, CA (United States)

    2017-05-15

    Management of abdominal aortic aneurysms (AAAs) is based on diameter. CT angiography (CTA) is commonly used, but requires radiation and iodinated contrast. Non-contrast MRI is an appealing alternative that may allow better characterization of intraluminal thrombus (ILT). This study aims to 1) validate non-contrast MRI for measuring AAA diameter, and 2) to assess ILT with CTA and MRI. 28 patients with AAAs (diameter 50.7 ± 12.3 mm) underwent CTA and non-contrast MRI. MRI was acquired at 3 T using 1) a conventional 3D gradient echo (GRE) sequence and 2) a 3D T{sub 1}-weighted black blood fast-spin-echo sequence. Two radiologists independently measured the AAA diameter. The ratio of signal of ILT and adjacent psoas muscle (ILT{sub r} = signal{sub ILT}/signal{sub Muscle}) was quantified. Strong agreement between CTA and non-contrast MRI was shown for AAA diameter (intra-class coefficient > 0.99). Both approaches had excellent inter-observer reproducibility (ICC > 0.99). ILT appeared homogenous on CTA, whereas MRI revealed compositional variations. Patients with AAAs ≥5.5 cm and <5.5 cm had a variety of distributions of old/fresh ILT types. Non-contrast 3D black blood MRI provides accurate and reproducible AAA diameter measurements as validated by CTA. It also provides unique information about ILT composition, which may be linked with elevated risk for disease progression. (orig.)

  5. Non-contrast 3D black blood MRI for abdominal aortic aneurysm surveillance: comparison with CT angiography

    International Nuclear Information System (INIS)

    Zhu, Chengcheng; Leach, Joseph R.; Hope, Michael D.; Tian, Bing; Liu, Qi; Lu, Jianping; Chen, Luguang; Saloner, David

    2017-01-01

    Management of abdominal aortic aneurysms (AAAs) is based on diameter. CT angiography (CTA) is commonly used, but requires radiation and iodinated contrast. Non-contrast MRI is an appealing alternative that may allow better characterization of intraluminal thrombus (ILT). This study aims to 1) validate non-contrast MRI for measuring AAA diameter, and 2) to assess ILT with CTA and MRI. 28 patients with AAAs (diameter 50.7 ± 12.3 mm) underwent CTA and non-contrast MRI. MRI was acquired at 3 T using 1) a conventional 3D gradient echo (GRE) sequence and 2) a 3D T_1-weighted black blood fast-spin-echo sequence. Two radiologists independently measured the AAA diameter. The ratio of signal of ILT and adjacent psoas muscle (ILT_r = signal_I_L_T/signal_M_u_s_c_l_e) was quantified. Strong agreement between CTA and non-contrast MRI was shown for AAA diameter (intra-class coefficient > 0.99). Both approaches had excellent inter-observer reproducibility (ICC > 0.99). ILT appeared homogenous on CTA, whereas MRI revealed compositional variations. Patients with AAAs ≥5.5 cm and <5.5 cm had a variety of distributions of old/fresh ILT types. Non-contrast 3D black blood MRI provides accurate and reproducible AAA diameter measurements as validated by CTA. It also provides unique information about ILT composition, which may be linked with elevated risk for disease progression. (orig.)

  6. Comparison of 16-row multislice CT angiography with conventional angiography for detection and evaluation of intracranial aneurysms

    International Nuclear Information System (INIS)

    Donmez, Halil; Serifov, Elman; Kahriman, Guven; Mavili, Ertugrul; Durak, Ahmet Candan; Menkue, Ahmet

    2011-01-01

    Purpose: The aim of this study is to compare the diagnostic performance of 16-row computed tomographic angiography (MDCTA) with digital subtraction angiography (DSA) for the detection and characterization of intracranial aneurysms in patients with nontraumatic subarachnoid hemorrhages (SAH). Materials and methods: One-hundred and twelve consecutive patients with suspected intracranial aneurysm underwent both 16-row MDCTA and DSA. The MDCT angiograms were interpreted in a blinded fashion by using combination with VRI, MIP and MPR techniques. Sensitivity specificity and accuracy were calculated for the CTA and DSA. The results were compared with each other. The DSA reader's interpretation was accepted as the reference standard. Results: A total of 164 aneurysms were detected at DSA in 112 patients, no aneurysms were detected by DSA and MDCTA in 16 patients. Eight aneurysms were missed by MDCTA. The overall sensitivity, specificity, and accuracy of MDCTA on a per-aneurysm basis were 95.1%, 94.1%, and 95%, respectively. According to the size of the aneurysm less than 3 mm; sensitivity, specificity and diagnostic accuracy of MDCTA were 86.1%, 94.1%, 88.6%, respectively. Conclusion: This study suggests that MDCTA is equally as sensitive as DSA in the detection of intracranial aneurysms of greater than 3 mm, and it also reveals 100% detection rate for ruptured aneurysms.

  7. Hemodynamic Changes Caused by Flow Diverters in Rabbit Aneurysm Models: Comparison of Virtual and Realistic FD Deployments Based on Micro-CT Reconstruction

    Science.gov (United States)

    Fang, Yibin; Yu, Ying; Cheng, Jiyong; Wang, Shengzhang; Wang, Kuizhong; Liu, Jian-Min; Huang, Qinghai

    2013-01-01

    Adjusting hemodynamics via flow diverter (FD) implantation is emerging as a novel method of treating cerebral aneurysms. However, most previous FD-related hemodynamic studies were based on virtual FD deployment, which may produce different hemodynamic outcomes than realistic (in vivo) FD deployment. We compared hemodynamics between virtual FD and realistic FD deployments in rabbit aneurysm models using computational fluid dynamics (CFD) simulations. FDs were implanted for aneurysms in 14 rabbits. Vascular models based on rabbit-specific angiograms were reconstructed for CFD studies. Real FD configurations were reconstructed based on micro-CT scans after sacrifice, while virtual FD configurations were constructed with SolidWorks software. Hemodynamic parameters before and after FD deployment were analyzed. According to the metal coverage (MC) of implanted FDs calculated based on micro-CT reconstruction, 14 rabbits were divided into two groups (A, MC >35%; B, MC 0.05). The normalized mean WSS in Group A after realistic FD implantation was significantly lower than that of Group B. All parameters in Group B exhibited no significant difference between realistic and virtual FDs. This study confirmed MC-correlated differences in hemodynamic parameters between realistic and virtual FD deployment. PMID:23823503

  8. Clinical application of 64 multi-slice CT angiography for the follow-up of endovascular stent-graft exclusion

    International Nuclear Information System (INIS)

    Yin Longlin; Chen Jiayuan; Jiang Jin; Yang Zhigang; Li Zhenlin; Sun Jiayu; Zhu Hongmei

    2009-01-01

    Objective: To investigate the clinical applications of 64-MSCTA for the follow-up of endovascular stent-graft exclusion (EVE). Methods: Between Oct 2006 and Feb 2008, forty-four 64-MSCTA examinations were performed in 30 patients with aortic dissection (AD) and 5 patients with abdominal aortic aneurysm (AAA) who underwent EVE. Imaging reconstruction including MPR, MIP and VR were finished on workstation. The outcomes and complications after EVE of aortic dissection and aortic aneurysm were evaluated. Results: (1) Of 30 patients with aortic dissection, large thrombosis in false lumen was observed in 28 cases and small thrombosis in 2 cases. The cavity of aortic aneurysm outside the stent was thrombosed completely in 5 patients with AAA. (2) Thrombosis in the innominate artery on follow-up CTA after EVE was found in 1 AD patient with the innominate artery involved, Thrombosis in the superior mesenteric artery was observed on 15 days follow-up CTA but thrombolysis on 3 months after EVE in 1 case, Intimal tear in right common iliac artery was found in 1 case. Of 5 patients with AAA, occlusion of right inner iliac artery was observed in 1 case, and instent thrombosis in distal right common iliac artery was found in 1 case. (3) Endoleak was found in 14 patients with AD, including 8 with type I and 6 with type III endoleaks, one type III endoleak was disappeared on follow-up CTA after 3 months. Conclusions: 64-MSCTA with fast, non-invasive and effective merits, combining multiple reconstructive methods, has become one of preferred imaging methods in post-operative evaluation of EVE. (authors)

  9. The blood flow channel index as novel predictor of abdominal aortic aneurysm impending rupture based on the intraluminal thrombus angio-CT study

    International Nuclear Information System (INIS)

    Wiernicki, Ireneusz; Szumilowicz, Pawel; Kazimierczak, Arkadiusz; Falkowski, Aleksander; Rutkowski, Donald; Gutowski, Piotr

    2015-01-01

    Objective: In this study the hypothesis that the thickness of the thinnest part of the thrombus, combined with bleeding into the intraluminal thrombus (ILT), is associated with a possible higher risk of abdominal aortic aneurysm (AAA) rupture was investigated, independently of aneurysm diameter, by using angio-CT. This article describes blood flow channel index based on the CT imaging findings that may help identify impending rupture prior to complete rupture. Methods: Computed tomographic images of 310 hospitalized patients with infrarenal AAA, were collected over a three-year period. They were divided into two main groups: 125 with bleeding into the ILT and control group 185 without the presence of blood in the thrombus. Patients were also analyzed in subgroups with ruptured, symptomatic and asymptomatic AAAs. A blood flow channel index was formulated as: maximal/minimal thickness ratio of thrombus from the same CT scan. Results: In dissected ILT group blood flow channel index was over a twofold higher than in group with intact ILT (19.0 [1.2–89.3] vs. (9.7 [1.3–38.9]; p < 0.001), respectively. Median thickness at the thinnest part of the ILT in dissected thrombus group was lower (1.3 mm [0.3–16.0]) than in group with intact ILT (1.7 mm [0.2–23.4]; p < 0.003). Conclusion: An association between a high blood flow channel index and bleeding into the ILT based on angio-CT study was demonstrated, and can suggest the aneurysm propensity for rupture

  10. The blood flow channel index as novel predictor of abdominal aortic aneurysm impending rupture based on the intraluminal thrombus angio-CT study

    Energy Technology Data Exchange (ETDEWEB)

    Wiernicki, Ireneusz, E-mail: irekwie@wp.eu [Department of Vascular Surgery and Angiology, Pomeranian Medical University, Szczecin (Poland); Szumilowicz, Pawel; Kazimierczak, Arkadiusz [Department of Vascular Surgery and Angiology, Pomeranian Medical University, Szczecin (Poland); Falkowski, Aleksander; Rutkowski, Donald [Department of Interventional Radiology, Pomeranian Medical University, Szczecin (Poland); Gutowski, Piotr [Department of Vascular Surgery and Angiology, Pomeranian Medical University, Szczecin (Poland)

    2015-04-15

    Objective: In this study the hypothesis that the thickness of the thinnest part of the thrombus, combined with bleeding into the intraluminal thrombus (ILT), is associated with a possible higher risk of abdominal aortic aneurysm (AAA) rupture was investigated, independently of aneurysm diameter, by using angio-CT. This article describes blood flow channel index based on the CT imaging findings that may help identify impending rupture prior to complete rupture. Methods: Computed tomographic images of 310 hospitalized patients with infrarenal AAA, were collected over a three-year period. They were divided into two main groups: 125 with bleeding into the ILT and control group 185 without the presence of blood in the thrombus. Patients were also analyzed in subgroups with ruptured, symptomatic and asymptomatic AAAs. A blood flow channel index was formulated as: maximal/minimal thickness ratio of thrombus from the same CT scan. Results: In dissected ILT group blood flow channel index was over a twofold higher than in group with intact ILT (19.0 [1.2–89.3] vs. (9.7 [1.3–38.9]; p < 0.001), respectively. Median thickness at the thinnest part of the ILT in dissected thrombus group was lower (1.3 mm [0.3–16.0]) than in group with intact ILT (1.7 mm [0.2–23.4]; p < 0.003). Conclusion: An association between a high blood flow channel index and bleeding into the ILT based on angio-CT study was demonstrated, and can suggest the aneurysm propensity for rupture.

  11. Endovascular Exclusion of Renal Artery Aneurysm

    International Nuclear Information System (INIS)

    Andersen, Poul Erik; Rohr, Nils

    2005-01-01

    A patient who was operated for an abdominal aortic aneurysm 7 years earlier presented with recently discovered iliac and renal artery aneurysms. The renal artery had an angulation of 90 o , but the aneurysm was successfully excluded using a covered vascular stent graft placed over an extrastiff guidewire. Even in cases of complex anatomy of a renal aneurysm, endovascular treatment should be considered. With development of more flexible and low-profile endoprosthesis with accurate deployment, these have become more usable

  12. Microsurgical management of cerebral aneurysms based in CT angiography with three-dimensional reconstruction (3D-CTA) and without preoperative cerebral angiography

    International Nuclear Information System (INIS)

    Gonzalez-Darder, J.M.; Pesudo-Martinez, J.V.; Feliu-Tatay, R.A.

    2001-01-01

    Objective. To study the possibilities of the microsurgical management of ruptured intracranial aneurysms with the sole preoperative information provided by computed tomography angiography with three-dimensional reconstruction (3D-CTA). Methods. Patients were studied with 3D-CTA after diagnosis of subarachnoid hemorrhage. If the study had an adequate quality and revealed an aneurysm congruent with the clinical findings or neurological examination and/or with the location of the bleeding on computed tomography (CT) scan an early microsurgical clipping of the lesion was done. When the quality of the 3D-CTA study was not adequate or the quality being adequate displayed no lesions or the findings were not accurate enough to warrant direct microsurgical treatment, the patient was studied with cerebral digital substraction (DS) angiography. A total of 44 consecutive patients harboring a total of 47 intracranial aneurysms diagnosed by 3D-CTA and without preoperative DS angiography were submitted to microsurgical clipping and included in the study. Results. The overall mortality was 15.9 % and the favorable results evaluated 6 months after discharge by means of the Glasgow outcome scale reached 70.4 %. All lesions were successfully clipped. Surgery was done a mean of 4.1 days after the admission bleeding. A total of four microlesions undiagnosed by 3D-CTA were found at surgery and clipped. Postoperative DS angiography and necropsy findings were also used as control of the 3D-CTA findings but no additional information was provided excepting the finding in DS angiography of an asymptomatic intracavemous aneurysm. Therefore the sensitivity of the 3D-CTA for diagnosis of symtomatic aneurysms was 100 % and the overall sensitivity 90.4 %. Conclusions. We have reached similar results in patients operated on with or without preoperative angiography. 3D-CTA provides very valuable anatomical information, which has an additional value in the microsurgical treatment of aneurysms of the

  13. Arteriovenous fistula of the superior gluteal artery as a complication of posterior iliac crest bone graft harvesting: 3D-CT angiography and arterial embolization

    OpenAIRE

    Kong, Chae-Gwan; Park, Jong-Beom; Won, Yoo-Dong; Riew, K. Daniel

    2009-01-01

    Superior gluteal artery injuries are rare, but potentially serious complications that occur during posterior iliac crest bone graft harvesting. The authors reported an arteriovenous fistula of the superior gluteal artery, which occurred as a complication during posterior iliac crest bone graft harvesting and was diagnosed with 3D-CT angiography, then treated with arterial embolization.

  14. Aneurysmal bone cyst of the mandibular condyle with condylar neck fracture

    Energy Technology Data Exchange (ETDEWEB)

    Park, Jeong Hoon [Department of Biomedical Engineering, College of Medicine and Healthcare Industry Research Institute, Kyung Hee University, Seoul (Korea, Republic of); Yu, Jae Jung; Kang, Ju Han; Kim, Gyu Tae; Choi, Yong Suk; Hwang, Eui Hwan [Department of Oral and Maxillofacial Radiology, School of Dentistry and Institute of Oral Biology, Kyung Hee University, Seoul (Korea, Republic of)

    2009-12-15

    Aneurysmal bone cyst (ABC) is relatively rare, non-neoplastic expansible lesion of bone. The case of a 15-year-old male with a ABC of the left mandibular condyle is presented. Panoramic radiograph showed a unilocular radiolucency with thinned coritces and a subcondylar fracture which was due to the trauma. Computed tomography (CT) revealed expansible lesion which had similar attenuation soft tissue. The patient was treated surgically including iliac crestal bone graft.

  15. Aneurysmal bone cyst of the mandibular condyle with condylar neck fracture

    International Nuclear Information System (INIS)

    Park, Jeong Hoon; Yu, Jae Jung; Kang, Ju Han; Kim, Gyu Tae; Choi, Yong Suk; Hwang, Eui Hwan

    2009-01-01

    Aneurysmal bone cyst (ABC) is relatively rare, non-neoplastic expansible lesion of bone. The case of a 15-year-old male with a ABC of the left mandibular condyle is presented. Panoramic radiograph showed a unilocular radiolucency with thinned coritces and a subcondylar fracture which was due to the trauma. Computed tomography (CT) revealed expansible lesion which had similar attenuation soft tissue. The patient was treated surgically including iliac crestal bone graft.

  16. Spinal arterial anatomy and risk factors for lower extremity weakness following endovascular thoracoabdominal aortic aneurysm repair with branched stent-grafts.

    Science.gov (United States)

    Chang, Catherine K; Chuter, Timothy A M; Reilly, Linda M; Ota, Maile K; Furtado, Andre; Bucci, Monica; Wintermark, Max; Hiramoto, Jade S

    2008-06-01

    To evaluate spinal arterial anatomy and identify risk factors for lower extremity weakness (LEW) following endovascular thoracoabdominal aortic aneurysm (TAAA) repair. A retrospective review was conducted of 37 patients (27 men; mean age 74.8+/-7.1 years, range 58-86) undergoing endovascular TAAA repair with branched stent-grafts at a single academic institution from July 2005 to December 2007. Data were collected on preoperative comorbidities, duration of operation, blood loss, type of anesthesia, extent of aortic coverage, blood pressure, cerebrospinal fluid (CSF) pressure and drainage, and postoperative development of LEW. Pre- and postoperative contrast-enhanced computed tomographic angiograms (CTA) in a 26-patient subset were analyzed to evaluate the number of patent intercostal and lumbar arteries before and after repair. All patients were neurologically intact at the end of the operation. Seven (19%) patients developed LEW postoperatively: 6 perioperatively and 1 after discharge. LEW was associated with postoperative hypotension, internal iliac artery (IIA) occlusion, and fewer patent segmental arteries on preoperative CTA. Lowest mean systolic blood pressure was segmental arteries in patients with or without LEW. Endovascular TAAA repair inevitably occludes direct inflow to lumbar and intercostal arteries. The distal segments of these arteries to the spine, however, are seen to remain patent through collaterals. Measures to preserve collateral pathways and increase perfusion pressure may help prevent or treat LEW.

  17. Revascularization of femoral head ischemic necrosis with vascularized bone graft: A CT scan experimental study

    International Nuclear Information System (INIS)

    Gonzalez del Pino, J.; Knapp, K.; Gomez Castresana, F.; Benito, M.

    1990-01-01

    An ischemic necrosis of the femoral head was induced in 15 mongrel adult dogs using the technique described by Gartsman et al. Five weeks later, a free vascularized rib graft was transferred into the previously induced ischemic femoral head. High resolution computed tomographic scanning was used to evaluate revascularization 4, 8 and 12 weeks after grafting. The femoral head exhibited new vessel formation throughout the study. Arterial terminal branches arising from the rib graft medullary and periosteal circulations extended beyond the rib graft, entered the head, and reached the subchondral plate. Even where the rib graft did not replenish the central core of the head, there was vascular supply from the grafted bone's vascular tree. These results suggest that a free vascularized bone graft is able to revascularize an experimentally induced ischemic femoral head necrosis. (orig.)

  18. Application of Revasculization Technique in Aneurysm Surgery : Kyorin University Experience

    OpenAIRE

    栗田, 浩樹; 山口, 竜一; 池田, 俊貴; 原田, 洋一; 塩川, 芳昭; Hiroki, KURITA; Ryuichi, YAMAGUCHI; Toshiki, IKEDA; Youichi, HARADA; Yoshiaki, SHIOKAWA; 杏林大学医学部脳神経外科・脳卒中センター; 杏林大学医学部脳神経外科・脳卒中センター; 杏林大学医学部脳神経外科・脳卒中センター; 杏林大学医学部脳神経外科・脳卒中センター; 杏林大学医学部脳神経外科・脳卒中センター

    2008-01-01

    Between February 2004 and September 2005, revasculization technique was used in 10 patients with intracranial aneurysm to obliterate the aneurysm and to prevent ischemic complications. Five high-flow external carotid-internal carotid (EC-IC) bypasses with radial artery graft (EC-RA-M2) followed by proximal IC occlusion/trapping were used to obliterate unruptured IC-cavernous large/giant aneurysms and ruptured IC anterior wall aneurysms. One patient with ruptured VA-union dissecting aneurysm w...

  19. Anatomic changes of target vessels after fenestrated and branched aortic aneurysm repair.

    Science.gov (United States)

    Kalder, J; Keschenau, P; Tamm, M; Jalaie, H; Jacobs, M J; Greiner, A

    2014-04-01

    Objective of this study was to evaluate the anatomic changes of the stented target vessels after endovascular repair of complex aortic aneurysms. Between July 2011 and December 2013, 53 aortic aneurysms were treated in our department with fenestrated and branched stent-graft devices. Forty-two of these patients were pre- and postoperatively scanned with a high resolution computer tomography (CT) (Cook Zenith® fenestrated or branched, Australia Pty. Ltd., Brisbane, Australia: N.=19; AnacondaTM fenestrated, Vascutek, Glasgow, Scotland, UK: N.=23). The other 11 out of the 53 patients did not receive a CT scan, because of a pre-existing renal failure. In the CT scans we retrospectively evaluated the anatomic vessel deviation at the origin of the target vessel and the vessel shift distal to the stent. For the first measurement the CT scans were loaded into OsiriX MD®, and the pre- and postoperative angles of the target vessels were measured and subtracted. For matching, the CT-scans were normalized at vertebral body lumbar 2. The second measured angle was the maximal measured angle distal to the target vessel stent-graft. Altogether, 113 target vessels were stented (celiac trunk [CT] 15, superior mesenteric arteries [SMA] 26, renal arteries [RA] 72), with 97 balloon-expandable PTFE stents: 90 Atrium V12 (Maquet Getinge group, Hudson, NH, USA), 7 BeGrafts (Bentley InnoMed, Hechingen, Germany) and 16 self-expandable fluency PTFE stents (Bard, Karlsruhe, Germany). The mean anatomic deviation at the target vessel origin was 28±17.3 and the mean vessel shift distal to the stent was 36.3±18.8. There were no significant differences between the main device and the target vessel stent types. Fenestrated and branched stent-graft solutions for aortic aneurysm repair induce changes of the target vessel anatomy. We did not observe significant differences between the several devices.

  20. Appreciation of CT-negative, lumbar puncture-positive subarachnoid haemorrhage: risk factors for presence of aneurysms and diagnostic yield of imaging.

    Science.gov (United States)

    Bakker, Nicolaas A; Groen, Rob J M; Foumani, Mahrouz; Uyttenboogaart, Maarten; Eshghi, Omid S; Metzemaekers, Jan D M; Luijckx, Gert Jan; Van Dijk, J Marc C

    2014-08-01

    Patients without a subarachnoid haemorrhage (SAH) on brain CT scan (CT-negative), but a lumbar puncture (LP)-proven SAH, are a challenging patient category. The optimal diagnostic approach is still a matter of debate. Also, there is little knowledge on the probability of finding an underlying vascular lesion. In this observational study, a consecutive cohort of 94 patients with CT-negative, LP-positive SAH was prospectively collected between 1998 and 2013. The yield of diagnostic modalities as well as patient outcome was studied. In addition, risk factors for the presence of a vascular lesion were analysed. In 40 patients (43%), an intracranial vascular abnormality was detected: 37 aneurysms and three arterial dissections. Female gender was significantly associated with detection of a vascular lesion. Time between ictus and diagnosis of SAH was not associated with the presence of vascular pathology. Overall, 99% of patients had a modified Rankin Score of 0-2 after a median follow-up of 72 months. The yield of additional digital subtraction angiography in patients with a negative CT angiography was zero. In this study, the chance of finding a vascular lesion in a patient with CT-negative, LP-positive SAH was 43%, underlining the need for an adequate diagnostic workup. In general, the patient outcome was favourable. Female gender was found to be predictive for detecting a vascular lesion. In contrast with previous reports, the interval between ictus and LP was not associated with the presence of an aneurysm. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.

  1. Functional renal perfusion imaging with colour mapping: is it a useful adjunct to spiral CT of in the assessment of abdominal aortic aneurysm (AAA)?

    International Nuclear Information System (INIS)

    Blomley, Martin J.K.; McBride, Alan; Mohammedtagi, Sima; Albrecht, Thomas; Harvey, Christopher J.; Jaeger, Rolf; Standfield, Nigel J.; Dawson, Peter

    1999-01-01

    Aim: To ensure optimal timing with pre-operative spiral CT for abdominal aortic aneurysms (AAA), an initial 'timing' single level CT is commonly performed with a small bolus of contrast. This can be exploited to obtain adjunct functional information on renal perfusion. We have investigated the potential of this to measure renal perfusion, to produce colour renal perfusion maps and to predict surgical outcome in infrarenal aortic aneurysm assessment. Methods: We studied 21 patients being assessed for repair of infrarenal AAA. Prior to the spiral CT, a single level through the renal hili and aorta was scanned after the intravenous injection of 25 ml of contrast given at 10 ml/s. Ten 1 s duration scans were performed from 8 to 30 s after injection. Optimal timing for CT angiography can then be determined. Time-density curves were then drawn for both kidneys and aorta using regions of interest (ROIs) or pixel-by-pixel analysis. Renal cortical perfusion was measured using both ROI analysis and pseudocolour perfusion images. Following previous work, perfusion was calculated as the peak upslope of the tissue time density curve divided by peak aortic enhancement. Results: Cortical mean perfusion averaged 2.48 ml/min per ml (range 0.8-3.7 ml/min per ml n=34) and the values obtained agreed with literature expectations. Follow up in the 10 patients proceeding to AAA repair suggest low mean perfusion values and predict a raised postoperative creatinine (P<0.05) Conclusions: Additional functional data and imaging can be obtained from the initial timing scan of a CT study, without requiring a dedicated study

  2. Pilot study of dynamic cine CT angiography for the evaluation of abdominal aortic aneurysms : Implications for endograft treatment

    NARCIS (Netherlands)

    Teutelink, A; Rutten, A; Muhs, BE; Olree, M; van Herwaarden, JA; de Vos, AM; Prokop, M; Moll, FL; Verhagen, HJM

    Purpose: To utilize 40-slice electrocardiographically (ECG)-gated cine computed tomographic angiography (CTA) to characterize normal aortic motion during the cardiac cycle at relevant anatomical landmarks in preoperative abdominal aortic aneurysm (AAA) patients. Methods: In 10 consecutive

  3. CT and angiographic analysis of posterior communicating artery aneurysms: What factors influence the amount of subarachnoid blood?

    International Nuclear Information System (INIS)

    Kim, Young Min; Jung, Kun Sik; Rho, Myung Ho; Choi, Pil Youb; Sung, Young Soon; Kwon, Jae Soo; Lee, Sang Wook

    1998-01-01

    To determine how clinical and angiographic factors relate to the amount of subarachnoid blood detected by computerized tomography in patients with a ruptured aneurysm. Between January 1996 and December 1997, 22 patients with a posterior communicating artery aneurysm were retrospectively evaluated. Oval(three of four cases), funnel(both cases), and daughter-sac (four of five cases) types of aneurysmal sac were found among the 13 patients with a large amount of subarachnoid blood;eight of these had a past history of hyertension or diabetes. Seven of eleven cases of cylindricaltype aneurysmal sac were found among the 9 patients with a small amount of sularachnoid blood;eight of these had no past history of hypertension or diabetes. The average S/N ratio (ratio of maximum sac length to neck diameter) of patients with a small amount of blood was higher than that of patients with a large amount of blood(2.72 vs 2.07). Although many factors influence the amount of subarachnoid blood in an aneurysmal rupture, we found that a large amount of blood was frequently present in the oval, funnel and daughter sac types of aneurysm, when S/N ratio was low, and when an underlying disease such as hypertension or diabetes was present. Conversely, a small amount of blood was present in the cylindrical type, when S/N ratio was high, and where there was no underlying disease.=20

  4. Intracranial aneurysm segmentation in 3D CT angiography: Method and quantitative validation with and without prior noise filtering

    International Nuclear Information System (INIS)

    Firouzian, Azadeh; Manniesing, Rashindra; Flach, Zwenneke H.; Risselada, Roelof; Kooten, Fop van; Sturkenboom, Miriam C.J.M.; Lugt, Aad van der; Niessen, Wiro J.

    2011-01-01

    Intracranial aneurysm volume and shape are important factors for predicting rupture risk, for pre-surgical planning and for follow-up studies. To obtain these parameters, manual segmentation can be employed; however, this is a tedious procedure, which is prone to inter- and intra-observer variability. Therefore there is a need for an automated method, which is accurate, reproducible and reliable. This study aims to develop and validate an automated method for segmenting intracranial aneurysms in Computed Tomography Angiography (CTA) data. Also, it is investigated whether prior smoothing improves segmentation robustness and accuracy. The proposed segmentation method is implemented in the level set framework, more specifically Geodesic Active Surfaces, in which a surface is evolved to capture the aneurysmal wall via an energy minimization approach. The energy term is composed of three different image features, namely; intensity, gradient magnitude and intensity variance. The method requires minimal user interaction, i.e. a single seed point inside the aneurysm needs to be placed, based on which image intensity statistics of the aneurysm are derived and used in defining the energy term. The method has been evaluated on 15 aneurysms in 11 CTA data sets by comparing the results to manual segmentations performed by two expert radiologists. Evaluation measures were Similarity Index, Average Surface Distance and Volume Difference. The results show that the automated aneurysm segmentation method is reproducible, and performs in the range of inter-observer variability in terms of accuracy. Smoothing by nonlinear diffusion with appropriate parameter settings prior to segmentation, slightly improves segmentation accuracy.

  5. One Year Outcomes of 101 BeGraft Stent Grafts used as Bridging Stents in Fenestrated Endovascular Repairs.

    Science.gov (United States)

    Spear, Rafaelle; Sobocinski, Jonathan; Hertault, Adrien; Delloye, Matthieu; Azzauiu, Richard; Fabre, Dominique; Haulon, Stéphan

    2018-04-01

    To evaluate the outcomes of the second generation BeGraft balloon expandable covered stent Graft System (Bentley InnoMed, Hechingen, Germany) implanted as bridging stent grafts during fenestrated endovascular aortic repair (FEVAR) of complex aneurysms. This was a single centre prospective study including all consecutive patients treated by FEVAR performed with second generation BeGraft stent grafts as bridging stents. Demographics of patients, diameter and length of the bridging stent grafts, technical success, re-interventions, occlusions, post-operative events, and imaging (Cone Beam CT and/or CT scan, and contrast enhanced ultrasound) were prospectively collected in an electronic database. Duplex ultrasound was performed before discharge and at 6 month follow-up. At 1 year, patients were evaluated clinically and by imaging (CT and ultrasound). Between November 2015 and September 2016, 39 consecutive patients (one woman) were treated with custom made fenestrated endografts (2-5 fenestrations) for complex aneurysms or type 1 endoleak after EVAR, using a variety of bridging stents including the BeGraft. All 101 BeGraft stent grafts were successfully delivered and deployed. There was no in hospital mortality. Early fenestration patency rate was 99% (96/97); the sole target vessel post-operative occlusion was secondary to a dissection of the renal artery distal to the stent. Complementary stenting was unsuccessful in recovering renal artery patency; bilateral renal stent occlusion was observed in the same patient on a CT scan performed 2 months after the procedure. He required post-operative dialysis. No additional renal impairment was observed. During follow-up (median 13 months [11-15]), all fenestrations stented with BeGraft stent grafts remained patent (95/97, 98%). One type 1b endoleak was detected and treated (2.6%). BeGraft stent grafts used as bridging stents during FEVAR are associated with favourable outcomes at 1 year follow-up. Long-term follow-up is

  6. Sequential changes of magnetic resonance images of intracavernous giant aneurysm following carotid ligation

    International Nuclear Information System (INIS)

    Kinjo, Toshihiko; Mukawa, Jiro; Takara, Eiichi; Mekaru, Susumu; Ishikawa, Yasunari

    1986-01-01

    A case of intracavernous giant aneurysm treated by combined carotid ligation and extracranial-intracranial vein-graft bypass is reported with special reference to the sequential changes of Magnetic Resonance Images (MRI). A 29-year-old female was admitted to our clinic with complaint of diplopia. She had no neurological deficit except for left abducens palsy. Left carotid angiogram revealed an intracavernous giant aneurysm, and vertebral angiogram revealed a fenestration at right and an aneurysm-like buldging at left vertebral artery. Gradual carotid occlusion after extracranial-intracranial bypass via grafted saphnous vein was successfully performed without any neurological complications. Sequential changes of MRI were as follows: The aneurysm was shown by absent intensity both in spin echo (SE) and inversion recovery (IR) methods before the treatment. It became isointensity in SE and two-tone intensity, iso at the center and high at the margin, in IR 15 days after, and, furtheremore, became slight high intensity in SE but decreased in two-tone intensity, low at the center and high at the margin, in IR 37 days after complete carotid occlusion. Coronal view was usefull to understand anatomical relationship. In conclusion, MRI, especially coronal IR method is of more diagnostic value than X-ray CT to follow the thrombosis of intracavernous aneurysm. (author)

  7. Accuracy of the CT-estimated weight of the right hepatic lobe prior to living related liver donation (LRLD) for predicting the intraoperatively measured weight of the graft

    International Nuclear Information System (INIS)

    Lemke, A.-J.; Brinkmann, M.; Felix, R.; Pascher, A.; Steinmueller, T.; Settmacher, U.; Neuhaus, P.

    2003-01-01

    Purpose: Due to the shortage of cadaver donors, living related liver donation (LRLD) has emerged as an alternative to cadaver donation. The expected graft weight is one of the main determinants for donor selection. This study investigates the accuracy of preoperatively performed CT-volumetry to predict the actual weight of the right liver lobe graft. Materials and methods: In a prospective study the weight of the right hepatic lobe was calculated by volumetric analysis based on CT in 33 patients (21 females, 12 males, mean age 42.1 years, median age 41 years) prior to living related liver donation. Graft weight was calculated as the product of CT-based graft volume and 1.00 g/ml (the approximated density of healthy liver parenchyma). The calculated weight was compared with the intraoperatively measured weight of the harvested right hepatic lobe. The difference was used to determine a correction factor for estimating the actual graft weight. Results: Based on the assumption of a parenchymal density of 1.00 g/ml, the preoperatively estimated graft weight (mean 980 g ± 168 g) deviated + 33% from the intraoperatively measured right hepatic lobe weight (mean 749 g ± 170 g). By reducing the preoperatively predicted weight of the right hepatic lobe with a correction factor of 0.75, the actual graft weight can be calculated [de

  8. Intraobserver and interobserver variability in CT angiography and MR angiography measurements of the size of cerebral aneurysms

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Hye Jeong [Hallym University College of Medicine, Department of Radiology, Kangnam Sacred Heart Hospital, Seoul (Korea, Republic of); Yoon, Dae Young; Lee, Hyung Jin [Hallym University College of Medicine, Department of Radiology, Kangdong Seong-Sim Hospital, Seoul (Korea, Republic of); Kim, Eun Soo [Hallym University College of Medicine, Department of Radiology, Hallym University Sacred Heart Hospital, Anyang, Gyeonggi-do (Korea, Republic of); Jeon, Hong Jun; Lee, Jong Young; Cho, Byung-Moon [Hallym University College of Medicine, Department of Neurosurgery, Kangdong Seong-Sim Hospital, Seoul (Korea, Republic of)

    2017-05-15

    Accurate and reliable measurement of aneurysm size is important for treatment planning. The purpose of this study was to determine intraobserver and interobserver variability of CTA and MRA for measurement of the size of cerebral aneurysms. Thirty patients with 33 unruptured cerebral aneurysms (saccular, >3 mm in their maximal dimension, with no daughter sacs or lobulations) who underwent 256-row multislice CTA, 3-D TOF MRA at 3.0T, and 3D rotational angiography (3DRA) were retrospectively analyzed. Three independent observers measured the neck, height, and width of the aneurysms using the CTA and MRA images. Intraobserver and interobserver variability of CTA and MRA measurements was evaluated using the standardized difference and intraclass correlation coefficient, with 3DRA measurements as the reference standard. In addition, the mean values of the measurements using CTA and MRA were compared with those using 3DRA. The overall intraobserver and interobserver standardized differences in CTA/MRA were 12.83-15.92%/13.48-17.45% and 14.08-17.00%/12.08-17.67%, respectively. The overall intraobserver and interobserver intraclass correlation coefficients of CTA/MRA were 0.88-0.98/0.84-0.96 and 0.86-0.98/0.85-0.95, respectively. Compared to the height and width measurements, measurements of the neck dimensions showed higher intraobserver and interobserver variability. The sizes of the cerebral aneurysms measured by CTA and MRA were 1.13-9.26 and 5.20-9.67% larger than those measured by 3DRA, respectively; however, these differences were not statistically significant. There were no noticeable differences between intraobserver and interobserver variability for both CTA- and MRA-based measurements of the size of cerebral aneurysms. (orig.)

  9. An extracardiac unruptured right sinus of valsalva aneurysm complicated with atherothrombosis

    Directory of Open Access Journals (Sweden)

    Jun Zhang

    2016-04-01

    Full Text Available We present quite a rare case of extracardiac unruptured right sinus of valsalva aneurysm (SVA complicated with atherothrombosis in a young adult man. A 35-year-old male with a giant unruptured SVA arising from the right coronary sinus (RCS with extracardiac protrusion was diagnosed by echocardiography. Contrast-enhanced computed tomography (CT revealed a huge calcified aneurysm with mural thrombi originating from the aortic root, and about 80% stenosis at the initial segment of the right coronary artery (RCA. Intraoperative exploration demonstrated a giant unruptured aneurysm arising from the RCS. Different from other SVAs reported before, this aneurismal wall appeared thick and atheromatous-like. In this aneurysm, there was a small localized intima tearing and mural thrombosis, and the orifice of the RCA was almost blocked. This patient underwent surgical patch repair to prevent aneurysm rupture and coronary artery bypass grafting for RCA revascularization. In conclusion, the pathological examination demonstrated marked foam cells, inflammatory cells, and thrombosis in the aneurismal wall. Learning points: • Echocardiographic characteristics of sinus of valsalva aneurysm (SVA. • Diagnostic evaluation of extracardiac unruptured SVA. • Pathology of rare SVA.

  10. Subclavian vein aneurysm secondary to a benign vessel wall hamartoma

    Energy Technology Data Exchange (ETDEWEB)

    Warren, Patrick [Nationwide Children' s Hospital, Section of Pediatric Interventional Radiology, Columbus, OH (United States); Spaeth, Maya [Nationwide Children' s Hospital, Section of Plastic and Reconstructive Surgery, Columbus, OH (United States); Prasad, Vinay [Nationwide Children' s Hospital, Section of Pediatric Pathology, Columbus, OH (United States); McConnell, Patrick [Nationwide Children' s Hospital, Section of Cardiothoracic Surgery, Columbus, OH (United States)

    2013-11-15

    Venous aneurysms are rare clinical entities, particularly in children, and their presentation and natural history often depend on the anatomical location and underlying etiology. We present a single case of a 12-year-old girl who presented with a palpable right supraclavicular mass. Imaging evaluation with CT, conventional venography, MRI and sonography revealed a large fusiform subclavian vein aneurysm with an unusual, mass-like fibrofatty component incorporated into the vessel wall. The girl ultimately required complete resection of the right subclavian vein with placement of a synthetic interposition graft. This case provides a radiology/pathology correlation of an entity that has not previously been described as well as an example of the utility of multiple imaging modalities to aid diagnosis and preoperative planning. (orig.)

  11. Perfect and least invasive sealing technique on the lesser curvature of the aortic arch: application of a novel stent graft to an aneurysm developing on a postoperative ductus arteriosus.

    Science.gov (United States)

    Soeda, Takeshi; Yokoi, Yoshihiko; Yuri, Koichi; Saito, Yuuhei; Setozaki, Shuji; Harada, Hisao

    2013-01-01

    A 78-year-old woman who underwent an operation for a patent ductus arteriosus (PDA) about thirty years ago developed an aneurysm on the aortic side of the remnant ductal tissue. To avoid risky, open surgery, we performed endovascular aortic therapy using a novel stent graft (SG), which was pre-curved, fenestrated and custom-made type. This graft was designed to configure to the patient's whole aortic arch anatomy, and was capable of accurately adjusting its fenestrations to the arch branch orifices during the procedure. The operation was successful, and the patient was discharged uneventfully on 16th postoperative day. The advantage of this fenestrated SG is close sealing, especially over the lesser curvature of the arch. This device could be a simple and effective option to deal with an otherwise normal aortic arch with such a ductus-related localized lesion.

  12. Elective visceral hybrid repair of type III thoracoabdominal aortic aneurysm

    Directory of Open Access Journals (Sweden)

    Marjanović Ivan

    2012-01-01

    Full Text Available Introduction. According to the classification given by Crawford et al. type III thoracoabdominal aortic aneurysm (TAAA is dilatation of the aorta from the level of the rib 6 to the separation of the aorta below the renal arteries, capturing all the visceral branch of aorta. Visceral hybrid reconstruction of TAAA is a procedure developed in recent years in the world, which involves a combination of conventional, open and endovascular aortic reconstruction surgery at the level of separation of the left subclavian artery to the level of visceral branches of aorta. Case report. We presented a 75-years-old man, with elective visceral hybrid reconstruction of type III TAAA. Computerized scanning (CT angiography of the patient showed type III TAAA with the maximum transverse diameter of aneurysm of 92 mm. Aneurysm started at the level of the sixth rib, and the end of the aneurysm was 1 cm distal to the level of renal arteries. Aneurysm compressed the esophagus, causing the patient difficulty in swallowing act, especially solid food, and frequent back pain. From the other comorbidity, the patient had been treated for a long time, due to chronic obstructive pulmonary disease and hypertension. In general endotracheal anesthesia with epidural analgesia, the patient underwent visceral hybrid reconstruction of TAAA, which combines classic, open vascular surgery and endovascular procedures. Classic vascular surgery is visceral reconstruction using by-pass procedure from the distal, normal aorta to all visceral branches: celiac trunk, superior mesenteric artery and both renal arteries, with ligature of all arteries very close to the aorta. After that, by synchronous endovascular technique a complete aneurysmal exclusion of thoracoabdominal aneurysm with thoracic stent-graft was performed. The postoperative course was conducted properly and the patient left the Clinic for Vascular Surgery on postoperative day 21. Control CT, performed 3 months after the surgery

  13. Optimal temporal windows and dose-reducing strategy for coronary artery bypass graft imaging with 256-slice CT

    Energy Technology Data Exchange (ETDEWEB)

    Lu, Kun-Mu [Department of Radiology, Shin Kong Wu Ho-Su Memorial Hospital, 95 Wen Chang Road, Shih Lin District, Taipei 111, Taiwan. (China); Lee, Yi-Wei [Department of Radiology, Kaohsiung Chang Gung Memorial Hospital and Chang Gung University College of Medicine, Kaohsiung, Taiwan (China); Department of Biomedical Imaging and Radiological Sciences, National Yang Ming University, Taipei, Taiwan (China); Guan, Yu-Xiang [Department of Biomedical Imaging and Radiological Sciences, National Yang Ming University, Taipei, Taiwan (China); Chen, Liang-Kuang [Department of Radiology, Shin Kong Wu Ho-Su Memorial Hospital, 95 Wen Chang Road, Shih Lin District, Taipei 111, Taiwan. (China); School of Medicine, Fu Jen Catholic University, Taipei, Taiwan (China); Law, Wei-Yip, E-mail: m002325@ms.skh.org.tw [Department of Radiology, Shin Kong Wu Ho-Su Memorial Hospital, 95 Wen Chang Road, Shih Lin District, Taipei 111, Taiwan. (China); Su, Chen-Tau, E-mail: m005531@ms.skh.org.tw [Department of Radiology, Shin Kong Wu Ho-Su Memorial Hospital, 95 Wen Chang Road, Shih Lin District, Taipei 111, Taiwan. (China); School of Medicine, Fu Jen Catholic University, Taipei, Taiwan (China)

    2013-12-11

    Objective: To determine the optimal image reconstruction windows in the assessment of coronary artery bypass grafts (CABGs) with 256-slice computed tomography (CT), and to assess their associated optimal pulsing windows for electrocardiogram-triggered tube current modulation (ETCM). Methods: We recruited 18 patients (three female; mean age 68.9 years) having mean heart rate (HR) of 66.3 beats per minute (bpm) and a heart rate variability of 1.3 bpm for this study. A total of 36 CABGs with 168 segments were evaluated, including 12 internal mammary artery (33.3%) and 24 saphenous vein grafts (66.7%). We reconstructed 20 data sets in 5%-step through 0–95% of the R–R interval. The image quality of CABGs was assessed by a 5-point scale (1=excellent to 5=non-diagnostic) for each segment (proximal anastomosis, proximal, middle, distal course of graft body, and distal anastomosis). Two reviewers discriminated optimal reconstruction intervals for each CABG segment in each temporal window. Optimal windows for ETCM were also evaluated. Results: The determined optimal systolic and diastolic reconstruction intervals could be divided into 2 groups with threshold HR=68. The determined best reconstruction intervals for low heart rate (HR<68) and high heart rate (HR>68) were 76.0±2.5% and 45.0±0% respectively. Average image quality scores were 1.7±0.6 with good inter-observer agreement (Kappa=0.79). Image quality was significantly better for saphenous vein grafts versus arterial grafts (P<0.001). The recommended windows of ETCM for low HR, high HR and all HR groups were 40–50%, 71–81% and 40–96% of R-R interval, respectively. The corresponding dose savings were about 60.8%, 58.7% and 22.7% in that order. Conclusions: We determined optimal reconstruction intervals and ETCM windows representing a good compromise between radiation and image quality for following bypass surgery using a 256-slice CT.

  14. Magnetic resonance angiography and CT angiography of persistent primitive olfactory artery: Incidence and association rate with aneurysm in Korea

    Energy Technology Data Exchange (ETDEWEB)

    Kwon, Bo Ra; Yeo, Soo Hyun; Chang, Hyuk Won; Kim, Mi Jeong; Lee, Sung Moon; Kim, Ealmaan; Kim, Mi Kyung; Cho, Ho Chan; Kim, Hye Soon [Keimyung University College of Medicine, Daegu (Korea, Republic of)

    2012-06-15

    Japanese data indicates an incidence of persistent primitive olfactory artery (PPOA) of 0.14%. We studied the incidence of PPOA and associated cerebral vascular variation or anomalies in Korea. We retrospectively reviewed cranial magnetic resonance angiography (MRA) and computed tomography angiography (CTA) images of a total of 9841 patients of our institution. The diagnostic criterion of PPOA is extreme anterioinferior course of the proximal anterior cerebral artery, with a hairpin turn of the lateral projection. We found 29 cases (0.29%) with PPOA. The PPOA location was on the left in 19 cases, bilateral in 3 cases, and on the right in 7 cases. An aneurysm was found at the hairpin turn in 2 patients. There were aneurysms in other sites in 3 cases. There were hypoplasia of anterior cerebral artery in 3 cases, and fenestration of intracranial artery in 1 case. In Korean populations, the incidence of PPOA found in MRA and CTA was twice as high as that shown in the previous Japanese data. Within Korea, left side laterality is more common than right side or bilalterality. Aneurysmal dilatations at the hairpin turning point and aneurysms at other sites were found, and other vascular variations were observed in several cases.

  15. Causes of acute deterioration in patients with a ruptured intracranial aneurysm. A prospective study with serial CT scanning

    NARCIS (Netherlands)

    Vermeulen, M.; van Gijn, J.; Hijdra, A.; van Crevel, H.

    1984-01-01

    The authors studied the acute neurological deterioration in 150 patients with aneurysmal hemorrhage. These patients were closely observed for a 4-week period or until death or operation. Forty-six patients suffered a total of 62 episodes of deterioration that developed within 5 minutes after

  16. Impact of metal artifact reduction software on image quality of gemstone spectral imaging dual-energy cerebral CT angiography after intracranial aneurysm clipping

    Energy Technology Data Exchange (ETDEWEB)

    Dunet, Vincent; Bernasconi, Martine; Hajdu, Steven David; Meuli, Reto Antoine; Zerlauth, Jean-Baptiste [Lausanne University Hospital, Department of Diagnostic and Interventional Radiology, Lausanne (Switzerland); Daniel, Roy Thomas [Lausanne University Hospital, Department of Neurosurgery, Lausanne (Switzerland)

    2017-09-15

    We aimed to assess the impact of metal artifact reduction software (MARs) on image quality of gemstone spectral imaging (GSI) dual-energy (DE) cerebral CT angiography (CTA) after intracranial aneurysm clipping. This retrospective study was approved by the institutional review board, which waived patient written consent. From January 2013 to September 2016, single source DE cerebral CTA were performed in 45 patients (mean age: 60 ± 9 years, male 9) after intracranial aneurysm clipping and reconstructed with and without MARs. Signal-to-noise (SNR), contrast-to-noise (CNR), and relative CNR (rCNR) ratios were calculated from attenuation values measured in the internal carotid artery (ICA) and middle cerebral artery (MCA). Volume of clip and artifacts and relative clip blurring reduction (rCBR) ratios were also measured at each energy level with/without MARs. Variables were compared between GSI and GSI-MARs using the paired Wilcoxon signed-rank test. MARs significantly reduced metal artifacts at all energy levels but 130 and 140 keV, regardless of clips' location and number. The optimal rCBR was obtained at 110 and 80 keV, respectively, on GSI and GSI-MARs images, with up to 96% rCNR increase on GSI-MARs images. The best compromise between metal artifact reduction and rCNR was obtained at 70-75 and 65-70 keV for GSI and GSI-MARs images, respectively, with up to 15% rCBR and rCNR increase on GSI-MARs images. MARs significantly reduces metal artifacts on DE cerebral CTA after intracranial aneurysm clipping regardless of clips' location and number. It may be used to reduce radiation dose while increasing CNR. (orig.)

  17. How to manage a case of aymptomatic thoraco-abdominal aortic aneurysm with occluded mesenteric arteries

    Directory of Open Access Journals (Sweden)

    Abhisekh Mohanty

    2015-12-01

    Full Text Available We report a unique case of a 57-year-old male having a suprarenal thoraco-abdominal aortic aneurysm which is extending till the origin of superior mesenteric artery (SMA. The origins of celiac artery and SMA were totally occluded and filled retrogradely through dense collateral vessels arising from the inferior mesenteric artery. Surprisingly, the patient was not having any symptoms related to mesenteric ischemia. We decided to use a conventional aortic aneurysm stent graft to repair it without revascularizing the occluded mesenteric arteries. After 1 month, CT aortogram was repeated which revealed a well-apposed stent graft with no endoleaks. He did not have any clinical signs and symptoms attributable to mesenteric ischemia.

  18. CT assisted follow-up of arthroscopically placed hydroxylapatite grafts in repair of fracture of the tibial head. Initial results of a CT assisted, quantitative assessment of the incorporation of the calcium hydroxylapatite graft and the reactions of the surrounding tissue

    International Nuclear Information System (INIS)

    Liebig, T.; Schedel, H.; Kodadadyan, Z.; Ricke, J.; Hoffmann, R.; Haas, N.; Felix, R.

    1996-01-01

    Four patients bearing a hydroxylapatite graft in repair of tibial head fracture have been examined by CT immediately after surgery and several times in the post operative period of up to 24 months. Density measurements of the graft, the spongiosa immediately next to it, and the spongiosa in fibula and tibia reveal the integration and ossous connection of the graft, quantifiable by the X-ray density. The spongiosa in immediate contact with the graft shows an initial density increase related to the first post-operative data, followed by a density decrease observed by subsequent measurements. These results are in agreement with animal experimental data and histomorphologic studies of other authors, which show that porous hydroxylapatite is used by the bone as a matrix serving as a pathway for osteoblast migration and subsequent ossification of the graft. Thus CT is capable of showing the post-operative integration process by quantifying and reproducible data. (orig.) [de

  19. RARE PRESENTATION OF SYMPTOMATIC BILATERAL PROXIMAL POPLITEAL ARTERY ANEURYSM

    Directory of Open Access Journals (Sweden)

    Thulasikumar Ganapathy

    2016-07-01

    Full Text Available True Popliteal artery aneurysm is the most common of all the peripheral artery aneurysms. We present a case of proximal popliteal artery aneurysm involvement both lower limb presented with gangrene in one lower limb and incapacitating claudication pain on the other lower limb. We have successfully repaired both sides aneurysm in the same sitting with Poly Tetra Fluro Ethylene (PTFE graft, as the patient also had multiple venous perforators’ involvement on both sides, which left us only with synthetic graft repair option rather than venous graft repair.

  20. Successful Endovascular Treatment of a Left Common Carotid Artery Aneurysm Following Failed Surgery of a Right Common Carotid Artery Aneurysm

    International Nuclear Information System (INIS)

    Cil, Barbaros E.; Ucar, Ibrahim; Ozsoy, Fatma; Arat, Anil; Yorgancioglu, Cem; Boeke, Erkmen

    2005-01-01

    Aneurysm of the common carotid artery is a rare and serious disease requiring prompt treatment in order to avoid neurologic complications. A 39-year-old man presented with voice impairment and a pulsatile mass at the right side of his neck and was found by color Doppler examination to have bilateral common carotid artery aneurysms of unknown origin. The right-sided large aneurysm was treated with placement of an 8 mm interposition Gore-Tex graft between the right common and internal carotid arteries. The surgical graft thrombosed 7 days after the surgery but the left-sided aneurysm was successfully treated by a Jostent peripheral stent-graft. Color Doppler examination showed a patent stent and no filling of the aneurysm on his first and sixth-month follow-up. Bilateral common carotid artery aneurysm is an exceptionally unusual condition and endovascular treatment of carotid artery aneurysms with covered stents may become an effective treatment alternative for these lesions

  1. Giant cell tumor with secondary aneurysmal bone cyst shows heterogeneous metabolic pattern on {sup 18}F-FDG PET.CT: A case reort

    Energy Technology Data Exchange (ETDEWEB)

    Park, Hee Jeong; Kwon, Seong Young; Yoon, Yeon Hong [Chonnam National University Hwasun Hospital, Huasun (Korea, Republic of); Cho, Sang Geon; Kim, Jahae; Song, Ho Chun; Kim, Sung Sun; Park, Jin Gyoon [Chonnam National University Hospital, Gwangju (Korea, Republic of)

    2016-12-15

    Giant cell tumor (GCT) is a generally benign bone tumor accounting for approximately 5 % of all primary bone neoplasms. Cystic components in GCTs that indicate secondary aneurysmal bone cysts (ABCs) are reported in 14 % of GCTs. Although both of them have been described separately in previous reports that may show considerable fluorodeoxyglucose (FDG) uptake despite their benign nature, the findings of GCT with secondary ABC on 18F-FDG positron emission tomography/computed tomography (PET/CT) have not been well-known. We report a case of GCT with secondary ABC in a 26-year-old woman. 18F-FDG PET/CT revealed a heterogeneous hypermetabolic lesion in the left proximal femur with the maximum standardized uptake value of 4.7. The solid components of the tumor showed higher FDG uptake than the cystic components. These observations suggest that the ABC components in GCTs show heterogeneous metabolic patterns on {sup 18}F-FDG PET/CT.

  2. Giant cell tumor with secondary aneurysmal bone cyst shows heterogeneous metabolic pattern on "1"8F-FDG PET.CT: A case reort

    International Nuclear Information System (INIS)

    Park, Hee Jeong; Kwon, Seong Young; Yoon, Yeon Hong; Cho, Sang Geon; Kim, Jahae; Song, Ho Chun; Kim, Sung Sun; Park, Jin Gyoon

    2016-01-01

    Giant cell tumor (GCT) is a generally benign bone tumor accounting for approximately 5 % of all primary bone neoplasms. Cystic components in GCTs that indicate secondary aneurysmal bone cysts (ABCs) are reported in 14 % of GCTs. Although both of them have been described separately in previous reports that may show considerable fluorodeoxyglucose (FDG) uptake despite their benign nature, the findings of GCT with secondary ABC on 18F-FDG positron emission tomography/computed tomography (PET/CT) have not been well-known. We report a case of GCT with secondary ABC in a 26-year-old woman. 18F-FDG PET/CT revealed a heterogeneous hypermetabolic lesion in the left proximal femur with the maximum standardized uptake value of 4.7. The solid components of the tumor showed higher FDG uptake than the cystic components. These observations suggest that the ABC components in GCTs show heterogeneous metabolic patterns on "1"8F-FDG PET/CT

  3. Idiopathic subvalvular aortic aneurysm masquerading as acute coronary syndrome.

    Science.gov (United States)

    Natarajan, Balaji; Ramanathan, Sundar; Subramaniam, Natarajan; Janardhanan, Rajesh

    2016-09-02

    Subvalvular aneurysms are the least common type of left ventricular (LV) aneurysms and can be fatal. Subaortic LV aneurysms are much rarer than submitral LV aneurysms and mostly reported in infancy. They can be congenital or acquired secondary to infections, cardiac surgery or trauma. Here, we report a unique presentation of a large, idiopathic subaortic aneurysm in an adult masquerading as an acute coronary syndrome. Diagnosis was made with the help of a CT aortography. Aneurysm was surgically resected with good results. This case highlights the clinical presentation and management of subaortic aneurysms, an important differential for congenital aortic malformations. 2016 BMJ Publishing Group Ltd.

  4. Bilateral giant femoropopliteal artery aneurysms: a case report

    Directory of Open Access Journals (Sweden)

    Perdikides Theodossios P

    2008-04-01

    Full Text Available Abstract Introduction Popliteal artery aneurysms are the most common peripheral arterial aneurysms, and are frequently bilateral. Acute limb ischemia, rupture and compression phenomena can complicate these aneurysms when the diameter exceeds 2 cm. Case Presentation We report an 82-year-old male patient with two giant femoropopliteal aneurysms, 10.5 and 8.5 cm diameters, managed in our institution. Both aneurysms were resected and a polytetrafluoroethylene (PTFE femoropopliteal interposition graft was placed successfully. Management and literature review are discussed. Conclusion We believe this is the first report in the medical literature of bilateral giant femoropopliteal aneurysms.

  5. Endovascular aneurysm repair: state-of-art imaging techniques for preoperative planning and surveillance

    DEFF Research Database (Denmark)

    Truijers, M; Resch, T; Van Den Berg, J C

    2009-01-01

    and dual-source CT could reduce radiation dose and obviate the need for nephrotoxic contrast. Up-to-date knowledge of non-invasive vascular imaging and image processing is crucial for EVAR planning and is essential for the development of follow-up programs involving reduced risk of harmful side effects....... dynamic CTA and MRA, provide valuable information on dynamic changes in aneurysm morphology that might have an important impact on endograft selection. During follow-up, imaging of the graft and aneurysm is of utmost importance to identify patients in need of secondary intervention. This has led...... to rigorous follow-up protocols including duplex ultrasound and regular CT examinations. The use of these intense follow-up protocols has recently been questioned because of high radiation dose and the frequent use of nephrotoxic contrast agents. New imaging modalities like contrast enhanced DUS, dynamic MR...

  6. Brain Aneurysm

    Science.gov (United States)

    A brain aneurysm is an abnormal bulge or "ballooning" in the wall of an artery in the brain. They are sometimes called berry aneurysms because they ... often the size of a small berry. Most brain aneurysms produce no symptoms until they become large, ...

  7. Early experience with transfemoral endovascular aneurysm management (TEAM) in the treatment of aortic aneurysms

    NARCIS (Netherlands)

    Balm, R.; Eikelboom, B. C.; May, J.; Bell, P. R.; Swedenborg, J.; Collin, J.

    1996-01-01

    OBJECTIVES: To evaluate the early experience with transfemoral endovascular aortic aneurysm management using the Endovascular Grafting System. DESIGN: Multi-centre prospective evaluation of the implantation procedure and early results (median follow-up 153 days). SETTING: Department of Surgery,

  8. CT and MR in aneurysm of the sinus of Valsalva diagnosis: two cases. TC y RM en el diagnostico del aneurisma del seno de Valsalva: a proposito de dos casos

    Energy Technology Data Exchange (ETDEWEB)

    Gonzalez-Granda Fernandez, F.; Navarro Sanchis, E.; Valdes Solis, P.; Sanchez-Lafuente, J.; Rodriguez San Pedro, F.

    1994-01-01

    We report two cases of aneurysm of the sinus of Valsalva that appeared as mediastinal masses having no related symptomatology. CT and MR studies were carried out in both cases. The assessment of the findings obtained with these two imaging methods led to the diagnosis, which was later confirmed by means of angiocardiography in one case and after surgery in the other. (Author) 19 refs.

  9. Aortic reconstruction with bovine pericardial grafts

    Directory of Open Access Journals (Sweden)

    Silveira Lindemberg Mota

    2003-01-01

    Full Text Available INTRODUCTION: Glutaraldehyde-treated crimped bovine pericardial grafts are currently used in aortic graft surgery. These conduits have become good options for these operations, available in different sizes and shapes and at a low cost. OBJECTIVE:To evaluate the results obtained with bovine pericardial grafts for aortic reconstruction, specially concerning late complications. METHOD: Between January 1995 and January 2002, 57 patients underwent different types of aortic reconstruction operations using bovine pericardial grafts. A total of 29 (50.8% were operated on an urgent basis (mostly acute Stanford A dissection and 28 electively. Thoracotomy was performed in three patients for descending aortic replacement (two patients and aortoplasty with a patch in one. All remaining 54 underwent sternotomy, cardiopulmonary bypass and aortic resection. Deep hypothermia and total circulatory arrest was used in acute dissections and arch operations. RESULTS: Hospital mortality was 17.5%. Follow-up was 24.09 months (18.5 to 29.8 months confidence interval and complication-free actuarial survival curve was 92.3% (standard deviation ± 10.6. Two patients lately developed thoracoabdominal aneurysms following previous DeBakey II dissection and one died from endocarditis. One "patch" aortoplasty patient developed local descending aortic pseudoaneurysm 42 months after surgery. All other patients are asymptomatic and currently clinically evaluated with echocardiography and CT scans, showing no complications. CONCLUSION: Use of bovine pericardial grafts in aortic reconstruction surgery is adequate and safe, with few complications related to the conduits.

  10. Postoperative three-dimensional CT angiography after cerebral aneurysm clipping with titanium clips: detection with single detector CT. Comparison with intra-arterial digital subtraction angiography

    International Nuclear Information System (INIS)

    Sakuma, I.; Tomura, N.; Kinouchi, H.; Takahashi, S.; Otani, T.; Watarai, J.; Mizoi, K.

    2006-01-01

    AIM: To assess the significance of three-dimensional computed tomography angiography (3D-CTA) in detecting remnant necks after cerebral aneurysm clipping. MATERIALS AND METHODS: A total of 59 patients (77 aneurysms) underwent surgery using titanium clips. Two blinded observers independently evaluated the presence of neck remnants on shaded-surface display (SSD) imaging, volume rendered (VR) imaging, and intra-arterial digital subtraction angiography (IADSA). RESULTS: Mean sensitivity and specificity for detecting neck remnants were 50.0 and 74.2% for SSD imaging, 61.5 and 82.8% for VR imaging, and 92.3 and 92.2% for IADSA, respectively. Receiver operating characteristic (ROC) analysis revealed excellent diagnostic performance for IADSA [mean area under ROC curve (Az)=0.97], and good diagnostic performance for 3D-CTA (Az=0.70 and 0.76 for SSD and VR, respectively). Specificity of VR was better than that SSD (p=0.082), however, there was no significant difference between them. CONCLUSION: Use of 3D-CTA techniques can facilitate postoperative evaluation

  11. CT Imaging Findings and Their Relevance to the Clinical Outcomes After Stent Graft Repair of Penetrating Aortic Ulcers: Six-year, Single-center Experience

    Energy Technology Data Exchange (ETDEWEB)

    Shin, Ji Hoon [University of Ulsan College of Medicine, Asan Medical Center, Department of Radiology and Research Institute of Radiology (Korea, Republic of); Angle, John F.; Park, Auh Whan; Anderson, Curtis; Sabri, Saher S.; Turba, Ulku C. [University of Virginia Health System, Division of Angiography, Interventional Radiology and Special Procedures, Department of Radiology (United States); Kern, John A.; Cherry, Kenneth J. [University of Virginia Health System, Department of Surgery (United States); Matsumoto, Alan H., E-mail: ahm4d@virginia.edu [University of Virginia Health System, Division of Angiography, Interventional Radiology and Special Procedures, Department of Radiology (United States)

    2012-12-15

    Purpose: To present the computed tomographic (CT) imaging findings and their relevance to clinical outcomes related to stent graft placement in patients with penetrating aortic ulcers (PAUs). Methods: Medical and imaging records and imaging studies were reviewed for consecutive patients who underwent stent graft repair of a PAU. The distribution and characteristics of the PAU, technical success of stent graft repair, procedure-related complications, associated aortic wall abnormalities, and outcomes of the PAUs at follow-up CT scans were evaluated. Results: Fifteen patients underwent endovascular treatment for PAU. A total of 87% of the PAUs were in the proximal (n = 8) or distal (n = 5) descending thoracic aorta. There was a broad spectrum of PAU depth (mean, 7.9 {+-} 5.6 mm; range 1.5-25.0 mm) and diameter (mean, 13.5 {+-} 9.7 mm; range 2.2-41.0 mm). Atherosclerosis of the thoracic aorta and intramural hematoma were associated in 53 and 93% of the patients, respectively. Technical success was achieved in 100%. Two or more stent grafts were used in five patients. Endoleaks were observed in two patients within 2 weeks of the procedure, both of which resolved spontaneously. At follow-up CT scanning, regression and thrombosis of the PAUs were observed in all patients. The average patient survival was 61.8 months, with an overall mortality of 13% (2 of 15) at follow-up. Neither death was related to the endograft device or the PAU. Conclusion: Endovascular stent graft placement was safe and effective in causing regression and thrombosis of PAUs in this small series of patients. Two or more stent grafts were used in five patients (33%) with associated long-segmental atherosclerotic changes of the thoracic aorta or intramural hematoma.

  12. CT Imaging Findings and Their Relevance to the Clinical Outcomes After Stent Graft Repair of Penetrating Aortic Ulcers: Six-year, Single-center Experience

    International Nuclear Information System (INIS)

    Shin, Ji Hoon; Angle, John F.; Park, Auh Whan; Anderson, Curtis; Sabri, Saher S.; Turba, Ulku C.; Kern, John A.; Cherry, Kenneth J.; Matsumoto, Alan H.

    2012-01-01

    Purpose: To present the computed tomographic (CT) imaging findings and their relevance to clinical outcomes related to stent graft placement in patients with penetrating aortic ulcers (PAUs). Methods: Medical and imaging records and imaging studies were reviewed for consecutive patients who underwent stent graft repair of a PAU. The distribution and characteristics of the PAU, technical success of stent graft repair, procedure-related complications, associated aortic wall abnormalities, and outcomes of the PAUs at follow-up CT scans were evaluated. Results: Fifteen patients underwent endovascular treatment for PAU. A total of 87% of the PAUs were in the proximal (n = 8) or distal (n = 5) descending thoracic aorta. There was a broad spectrum of PAU depth (mean, 7.9 ± 5.6 mm; range 1.5–25.0 mm) and diameter (mean, 13.5 ± 9.7 mm; range 2.2–41.0 mm). Atherosclerosis of the thoracic aorta and intramural hematoma were associated in 53 and 93% of the patients, respectively. Technical success was achieved in 100%. Two or more stent grafts were used in five patients. Endoleaks were observed in two patients within 2 weeks of the procedure, both of which resolved spontaneously. At follow-up CT scanning, regression and thrombosis of the PAUs were observed in all patients. The average patient survival was 61.8 months, with an overall mortality of 13% (2 of 15) at follow-up. Neither death was related to the endograft device or the PAU. Conclusion: Endovascular stent graft placement was safe and effective in causing regression and thrombosis of PAUs in this small series of patients. Two or more stent grafts were used in five patients (33%) with associated long-segmental atherosclerotic changes of the thoracic aorta or intramural hematoma.

  13. Ex vivo repair of renal artery aneurysm associated with surgical treatment of abdominal aortic aneurysm

    Directory of Open Access Journals (Sweden)

    Kostić Dušan M.

    2004-01-01

    Full Text Available INTRODUCTION Renal artery aneurysms is relatively uncommon with reported incidence ranges from 0.3% to 1%. However, considering all visceral artery aneurysms the percentage of renal artery aneurysms is relatively high between 15-25%. The distal forms of renal artery aneurysms sometimes require "ex vivo" reconstruction and kidney autotransplantation. CASE REPORT A 75-year-old male presented with the right abdominal and back pain. He suffered from a long history of arterial hypertension and chronic renal failure over the last few months (urea blood = 19.8 mmol/l; creatinine = 198 mmol/l. Duplex ultrasonography showed abdominal aortic aneurysm. Subsequent translumbarangiography revealed juxtarenal abdominal aortic aneurysm associated with distal right renal artery aneurysm. The operation was performed under combined thoracic epidural analgesia and general anesthesia using transperitoneal approach. After the laparotomy, the ascending colon was mobilized and reflected medially followed by Kocher maneuver. The result was visualization of the anterior aspect of the right kidney, the collecting system, ureter as well as the right renal vein and artery with large saccular aneurysm located distally. After mobilization of the renal vessels and careful dissection of the ureter, the kidney was explanted. The operation was continued by two surgical teams. The first team performed abdominal aortic aneurysm resection and reconstruction with bifurcated Dacron graft. The second team performed ex vivo reparation of renal artery aneurysm. All time during the explantation, the kidney was perfused by Collins' solution. The saccular right renal artery aneurysm 4 cm in diameter was located at the kidney hilus at the first bifurcation. Three branches originated from the aneurysm. The aneurysm was resected completely. The longest and widest of three branches arising from the aneurysmal sac was end-to-end anastomized with 6 mm PTFE graft. After this intervention, one of

  14. Penetrating Atherosclerotic Ulcer of the Descending Thoracic Aorta: Treatment by Endovascular Stent-Graft

    International Nuclear Information System (INIS)

    Murgo, Salvatore; Dussaussois, Luc; Golzarian, Jafar; Cavenaile, Jean Christophe; Abada, Hicham Tarik; Ferreira, Jose; Struyven, Julien

    1998-01-01

    Purpose: To present four cases of penetrating ulcer of the descending thoracic aorta treated by transfemoral insertion of an endoluminal stent-graft. Methods: Four patients with penetrating aortic ulcers were reviewed. Three cases were complicated by rupture, false aneurysm, or retrograde dissection. All patients were treated by endovascular stent-graft and were followed by helical computed tomography (CT). Results: Endovascular stent-graft deployment was successful in all patients. However, in one case we observed a perigraft leak that spontaneously disappeared within the first month, and two interventions were needed for another patient. Following treatment, one episode of transient spinal ischemia was observed. The 30-day survival rate was 100%, but one patient died from pneumonia with cardiac failure 34 days after the procedure. In one patient, helical CT performed at 3 months showed a false aneurysm independent of the first ulcer. This patient refused any further treatment and suddenly died at home (unknown cause) after a 6-month follow-up period. Conclusion: Transluminal placement of endovascular stent-grafts for treatment of penetrating ulcers of the descending thoracic aorta appears to be a possible alternative to classical surgery. After treatment, follow-up by CT is essential to detect possible complications of the disease

  15. Emergency Endovascular Treatment of Abdominal Aortic Aneurysms: Feasibility and Results

    International Nuclear Information System (INIS)

    Lagana, Domenico; Carrafiello, Gianpaolo; Mangini, Monica; Fontana, Federico; Caronno, Roberto; Castelli, Patrizio; Cuffari, Salvatore; Fugazzola, Carlo

    2006-01-01

    Purpose. To assess the feasibility and effectiveness of emergency endovascular treatment of abdominal aortic aneurysms (AAAs). Methods. During 36 months we treated, on an emergency basis, 30 AAAs with endovascular exclusion. In 21 hemodynamically stable patients preoperative CT angiography (CTA) was performed to confirm the diagnosis and to plan the treatment; 9 patients with hemorrhagic shock were evaluated with angiography performed in the operating room. Twenty-two Excluder (Gore) and 8 Zenith (Cook) stent-grafts (25 bifurcated and 5 aorto-uni-iliac) were used. The follow-up was performed by CTA at 1, 3, 6, and 12 months. Results. Technical success was achieved in 100% of cases with a 10% mortality rate. The total complication rate was 23% (5 increases in serum creatinine level and 2 wound infections). During the follow-up, performed in 27 patients (1-36 months, mean 15.2 months), 4 secondary endoleaks (15%) (3 type II, 2 spontaneously thrombosed and 1 under observation, and 1 type III treated by iliac extender insertion) and 1 iliac leg occlusion (treated with femoro-femoral bypass) occurred. We observed a shrinkage of the aneurysmal sac in 8 of 27 cases and stability in 19 of 27 cases; we did not observe any endotension. Conclusions. Endovascular repair is a good option for emergency treatment of AAAs. The team's experience allows correct planning of the procedure in emergency situations also, with technical results comparable with elective repair. In our experience the bifurcated stent-graft is the device of choice in patients with suitable anatomy because the procedure is less time-consuming than aorto-uni-iliac stent-grafting with surgical crossover, allowing faster aneurysm exclusion. However, further studies are required to demonstrate the long-term efficacy of endovascular repair compared with surgical treatment

  16. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... cavities (ventricles) in patients with hydrocephalus . diseases or malformations of the skull. CT scanning is also performed ... biopsy ) from the brain. assess aneurysms or arteriovenous malformations through a technique called CT angiography. For more ...

  17. Transportal femoral drilling creates more horizontal ACL graft orientation compared to transtibial drilling: A 3D CT imaging study.

    Science.gov (United States)

    Clockaerts, S; Van Haver, A; Verhaegen, J; Vuylsteke, K; Leenders, T; Lagae, K C; Verdonk, P

    2016-06-01

    The principle of anatomic anterior cruciate ligament (ACL) reconstruction is to create a femoral and tibial tunnel that resembles the insertion of the native ACL. Anatomic reconstruction leads to a more horizontal graft orientation that provides more rotational stability. The aim of this study is to investigate the best method to achieve anatomical reconstruction of femoral insertion of the ACL and thus, a more horizontal orientation of the ACL. We compared tunnel position and orientation between transportal femoral drilling technique and transtibial technique. Thirty-two patients were included. Post-operative CT scans were obtained and femur, tibia and ACL tunnels were reconstructed. The position and orientation of tibial and femoral tunnels were quantified using the quadrant method, and femoral tunnel length, ellipticity and posterior wall breakage were assessed. We also investigated clinical outcome. Analyses show that transportal drilled femoral tunnels were situated significantly lower than transtibial drilled tunnels (p<0.0001), resulting in a significantly more horizontal oriented ACL in the transportal group in coronal (p<0.0001) and sagittal plane (p=0.01). No differences were observed in depth of femoral tunnel position (p=0.44). Femoral tunnel length was shorter in the transportal group (p=0.01) with a more ellipsoidal femoral aperture (p=0.01). There were no differences between both groups in tibial position. There were no differences in clinical outcome measure between the transportal and transtibial groups. This study indicates that transportal drilling of the femoral tunnel leads to a more horizontal graft orientation of the ACL, without differences in clinical outcome. Copyright © 2016 Elsevier B.V. All rights reserved.

  18. Endovascular implantation of stent-grafts in the thoracic aorta - mid-term results of a prospective controlled study

    International Nuclear Information System (INIS)

    Duda, S.H.; Pusich, B.; Tepe, G.; Pereira, P.; Feuls, R.; Claussen, C.D.; Raygrotzki, S.; Aebert, H.; Ziemer, G.; Uckmann, F.P.

    2002-01-01

    Purpose: To evaluate the effectiveness and safety of endovascular treatment of various descending thoracic aortic pathologies with covered stent-grafts as an alternative to open surgery. Methods: Among 16 patients (5 type B dissections, 5 contained ruptures, 3 aneurysms of the descending aorta, 1 thoraco-abdominal aneurysm, 1 mural thrombosis, 1 patch aneurysm) treated between November 1997 and November 2000, eight patients received Talent TM stent-grafts and another 8 patients underwent a Gore-TAG TM stent-graft implantation. A clinical follow-up and control CT scans were obtained after the procedure and then at six-month intervals. Results: Deployment of the stent-grafts was technically successful in all cases. Sufficient aortic reconstruction was achieved in all but one patient who needed surgical treatment. One patient died two days after the procedure from aortic rupture due to retrograde type A dissection. Another patient died 19 months after the procedure from an unknown cause. There was no occurrence of distal embolization, paralysis or infection. During follow-up, all patients remained free from recurrence or late complications of their disease. Conclusion: Endoluminal treatment of thoracic aortic pathologies with covered stent-grafts appears to be a safe and feasible method with at least mid-term efficacy. (orig.) [de

  19. Endovascular aneurysm exclusion along a femorodistal venous bypass in active Behçet's disease.

    Science.gov (United States)

    Gretener, Silvia B; Do, Dai-Do; Baumgartner, Iris; Dinkel, Hans-Peter; Schmidli, Jürg; Birrer, Manuela

    2002-10-01

    To report the endovascular repair of dual aneurysms along a femorodistal venous bypass graft in a patient with Behçet's disease. A 55-year-old man of middle European ancestry with Behçet's disease had dual aneurysms evolve along the proximal segment of a femorodistal venous bypass that had been implanted 2.5 years earlier for recurrent false aneurysm formation. Owing to the lack of suitable venous conduits and the active nature of the disease, the aneurysms were successfully excluded with overlapping Hemobahn and Jostent endografts; the immunosuppressive therapy was intensified. Rupture of the aneurysms was successfully prevented, but the stent-grafts thrombosed 6 weeks later owing to exacerbation of the underlying disease. Endovascular exclusion of aneurysm in venous bypass grafts in Behçet's disease is feasible. Although the stent-grafts thrombosed, they did prevent rupture of the aneurysms.

  20. Portal circulation aneurysms: two case reviews

    International Nuclear Information System (INIS)

    Perret, W. L.; Silva, A de.; Elzarka, A.; Schelleman, A.

    2007-01-01

    Venous aneurysms of the superior mesenteric vein and portal vein are an uncommon occurrence and often an incidental finding. They can also be associated with hepatocellular disease and portal hypertension. We present CT and ultrasound findings of these entities. The management of venous aneurysms is generally conservative with serial imaging

  1. Detection of aneurysmal subarachnoid hemorrhage 3 months after initial bleeding: evaluation of T2* and FLAIR MR sequences at 3 T in comparison with initial non-enhanced CT as a gold standard.

    Science.gov (United States)

    Mulé, Sébastien; Soize, Sébastien; Benaissa, Azzedine; Portefaix, Christophe; Pierot, Laurent

    2016-08-01

    To investigate the ability of T2* and fluid-attenuated inversion recovery (FLAIR) MR sequences to detect hemosiderin deposition 3 months after aneurysmal subarachnoid hemorrhage (SAH) in comparison with early non-enhanced CT (NECT) as a gold standard. From September 2008 through May 2013, patients with aneurysmal SAH were included if a NECT less than 24 h after the onset of symptoms showed a SAH, and MRI, including T2* and FLAIR sequences, was performed 3 months later. All aneurysms were treated endovascularly. NECT and MR sequences were blindly analyzed for the presence of SAH (NECT) or hemosiderin deposition (MRI). When positive, details of the spatial distribution of SAH or hemosiderin deposits were noted. Sensitivities were calculated for each patient. Sensitivities, specificities, and positive predictive values (PPVs) were calculated for each location. Forty-nine patients (mean age 52.9 years) were included. Bleeding-related patterns were identified in 43 patients (87.8%) on T2* and 10 patients (20.4%) on FLAIR. T2* was highly predictive of the location of the initial hemorrhage, especially in the Sylvian cisterns (PPVs 95% and 100%) and the anterior interhemispheric fissure (PPV 90%). The T2* sequence can detect and localize a previous SAH a few months after aneurysmal bleeding. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/

  2. Rupture of popliteal arterial aneurysm due to salmonella infection

    International Nuclear Information System (INIS)

    Kim, Dong Hun; Oh, Hyung Woo; Kim, Dong Hyun; Byun, Joo Nam

    2006-01-01

    We report here on a case of popliteal aneurysm and rupture that occurred over a 10-day period and this was all secondary to salmonella infection. Computed tomography (CT) angiography of the extremity that was performed before and after aneurysmal rupture showed the aneurysm's rapid evolution to rupture over a short period of time. We also review the pathogenesis, clinical presentation, diagnostic approach and management of salmonella aneurysms

  3. Late type III endoleak after thoracic endovascular aneurysm repair and previous infrarenal stent graft implantation - a case report and review of the literature.

    Science.gov (United States)

    Leszczyński, Jerzy; Macioch, Waldemar; Chudziński, Witold; Gałązka, Zbigniew

    2017-09-01

    Thoracic endovascular aortic repair (TEVAR) effectively improved the results of thoracic aortic aneurysm treatment. TEVAR is a less invasive procedure that can be performed under local anesthesia with shorter hospital stay. The perioperative morbidity and mortality rates are lower for endovascular than open repair, but the rate of secondary interventions is higher for TEVAR. We report a case of an elderly man with synchronous abdominal and thoracic aortic aneurysms. A type III dangerous endoleak was recognized 3 years after TEVAR. It was successfully repaired during an endovascular procedure. There were no new endoleaks after 12 months of follow-up. TEVAR may be the only option of treatment for risky and elderly patients. However, postoperative monitoring is necessary to exclude different types of endoleaks. Most of them undergo effective endovascular repair.

  4. Endovascular stent-graft placement for the treatment of acute onset and chronic aortic dissections of the descending aorta (Short-term follow-up)

    International Nuclear Information System (INIS)

    Petrov, I; Jorgova, J.; Trendafilova, D.

    2004-01-01

    The leading cause of death for patients with surgically untreated thoracic aortic aneurysms is the rupture of the aneurysm. Almost one half of these patients are left to medical treatment assuming the risk of late rupture and aneurysm sac enlargement - the late surgical treatment of these patients is too risky and with poor results. On the other hand the emergent surgical treatment of these cases is related with relatively high mortality rate. Recently, thoracic aortic stent-grafting has emerged as a less traumatic alternative therapeutic modality for patients with thoracic aortic aneurysms and aortic dissections. The first case of stent implantation in a dissected descending aorta was performed in Bulgaria at 09.04.2003. Since then we implanted in 8 patients thoracic stent grafts, The mean age of the patients was 67.5 years. The primary success was 100%. One died on the second postoperative day by abdominal aorta rupture. No other complications were registered. The mean follow-up of 5 months proved to be uneventful and the control CT revealed efficacious sealing of the entry and false lumen thrombosis in all except one cases. We report our initial clinical experience of endovascular stent-graft repair for dissection of the descending aorta that is encouraging. These preliminary data suggest that endovascular stent-grafting is a viable treatment for acute onset and chronic aortic dissection type B

  5. Aorto-hepatic bypass graft for repair of an inferior pancreatico-duodenal artery aneurysm associated with coeliac axis occlusion: A case report

    Directory of Open Access Journals (Sweden)

    Tom Hughes

    2016-01-01

    Conclusion: Surgical excision with bypass grafting from the supra-coeliac aorta, as reported by our team, represents a satisfactory management option in patients where interventional approaches have failed or are not appropriate.

  6. Thoracic aortic aneurysm in a child due to cystic medial necrosis

    International Nuclear Information System (INIS)

    Kuribayashi, Sachio; Watabe, Tsuneya; Ohtaki, Makoto; Matsuyama, Shoya; Ogawa, Junichi

    1983-01-01

    The valuable role of computed tomography (CT) was stressed in the diagnosis of thoracic aortic aneurysm in an asymptomatic 12-year-old child. She initially presented mediastinal mass on plain chest film. A saccular thoracic aortic aneurysm was highly suspected from the CT findings, and it was confirmed on angiography. Pathological examination of the aneurysmal wall revealed cystic medial necrosis. (author)

  7. The effect of endoleak on intra-aneurysmal pressure after EVE for abdominal aortic aneurysm

    International Nuclear Information System (INIS)

    Huang Sheng; Jing Zaiping; Mei Zhijun; Lu Qingsheng; Zhao Jun; Zhang Suzhen; Zhao Xin; Cai Lili; Tang Jingdong; Xiong Jiang; Liao Mingfang

    2003-01-01

    Objective: To investigate the intra-aneurysmal pressure curve in the presence of endoleak after endovascular exclusion (EVE) for abdominal aortic aneurysm (AAA). Methods: Infrarenal aortic aneurysms were created with bovine jugular vein segments or patches. Then they were underwent incomplete endovascular exclusion of the aneurysm and formation of endoleaks. The pressures of blood flow outside the graft into the sac were measured. Results: The intrasac pressure was higher than systemic pressure in the presence of endoleak. After sealing the endoleak, pressure decreased significantly, and the pressure cure showed approximately linear. Conclusion: The change of intra-aneurysmal pressure curve reflected the load on aneurysmal wall after EVE, and can also help to determine the endoleak existence

  8. Using CT perfusion during the early baseline period in aneurysmal subarachnoid hemorrhage to assess for development of vasospasm

    International Nuclear Information System (INIS)

    Sanelli, Pina C.; Jou, Austin; Reichman, Melissa; Greenberg, Edward; Cayci, Zuzan; Gold, Rachel; John, Majnu; Ugorec, Igor; Rosengart, Axel

    2011-01-01

    The aim of this study is to evaluate computed tomography perfusion (CTP) during admission baseline period (days 0-3) in aneurysmal subarachnoid hemorrhage (A-SAH) for development of vasospasm. Retrospective analysis was performed on A-SAH patients from Dec 2004 to Feb 2007 with CTP on days 0-3. Cerebral blood flow (CBF), cerebral blood volume (CBV), and mean transit time (MTT) maps were analyzed for qualitative perfusion deficits. Quantitative analysis was performed using region-of-interest placement to obtain mean CTP values. Development of vasospasm was determined by a multistage hierarchical reference standard incorporating both imaging and clinical criteria. Student's t test and threshold analysis were performed. Seventy-five patients were included, 37% (28/75) were classified as vasospasm. Mean CTP values in vasospasm compared to no vasospasm groups were: CBF 31.90 ml/100 g/min vs. 39.88 ml/100 g/min (P < 0.05), MTT 7.12 s vs. 5.03 s (P < 0.01), and CBV 1.86 ml/100 g vs. 2.02 ml/100 g (P = 0.058). Fifteen patients had qualitative perfusion deficits with 73% (11/15) developed vasospasm. Optimal threshold for CBF is 24-25 mL/100 g/min with 91% specificity and 50% sensitivity, MTT is 5.5 s with 70% specificity and 61% sensitivity and CBV is 1.7 mL/100 g with 89% specificity and 36% sensitivity. These initial results support our hypothesis that A-SAH patients who develop vasospasm may demonstrate early alterations in cerebral perfusion, with statistically significant CBF reduction and MTT prolongation. Overall, CTP has high specificity for development of vasospasm. Future clinical implications include using CTP during the baseline period for early identification of A-SAH patients at high risk for vasospasm to prompt robust preventative measures and treatment. (orig.)

  9. Radiological analysis of subarachnoid hemorrhage from ruptured intracranial aneurysms

    International Nuclear Information System (INIS)

    Lee, Jong Doo; Suh, Jung Ho; Kim, Dong Ik

    1988-01-01

    The CT findings of 98 patients with subarachnoid hemorrhage due to aneurysmal rupture were analyzed and compared with cerebral angiography for the purpose of preangiographic prediction of aneurysmal location as well as evaluation of the CT features corresponding to the vasospasm or ischemic neurologic dysfunctions. The results were as follows: 1.Aneurysms could be identified on initial cerebral angiography in 82 out of 98 patients with subarachnoid hemorrhage and anterior communicating artery aneurysms were most common (42 cases), followed by MCA, posterior communicating artery, ICA, basilar artery in order of frequency. 2.The CT findings of those patients were hemorrhage in subarachnoid space (69%), localized hematoma (47%), ventricular dilatation (31%), enhancing nodule (23%), cisternal enhancement (20%), cerebral infarction (15%), ventricular hemorrhage (14%), and epidural hemorrhage (3%). 3.Localized hematoma was more prevalent in anterior communicating artery aneurysm rupture (54%), and less frequently in MCA, posterior communicating artery and ICA aneurysms. 4.Most of aneurysmal sac could be identified as enhancing nodule on CT when the real size were over 1 cm. 5.The size of ruptured aneurysm could be predicted in many patients with ACA and MCA aneurysm according to the CT features such as hemorrhagic patterns, location of hematomas or enhancing nodules. 6.Localized hematoma or blood clots and cerebral infarction are considered to be the CT features corresponding to the angiographic vasospasm

  10. Brain aneurysm repair

    Science.gov (United States)

    ... aneurysm repair; Dissecting aneurysm repair; Endovascular aneurysm repair - brain; Subarachnoid hemorrhage - aneurysm ... Your scalp, skull, and the coverings of the brain are opened. A metal clip is placed at ...

  11. CMR diagnosis of coronary graft fistula

    Directory of Open Access Journals (Sweden)

    Bengt Johansson

    2014-01-01

    Full Text Available The patient is a 54-year old man with a previous history of cerebral aqueduct stenosis and hydrocephalus resulting in malignant hypertension who had surgery for permanent ventriculo-peritoneal shunt. At age 41, he had coronary artery bypass graft (CABG surgery with the right internal mammary artery anastomosed to the posterior descending artery and a saphenous vein graft to the first obtuse marginal branch. The patient was recently admitted with pneumonia that rapidly deteriorated and he went in respiratory failure requiring mechanical ventilation. A thoracic CT investigation showed massive bilateral pulmonary infiltrates, pulmonary artery embolism and a large vein graft aneurysm with a maximal diameter of 40 mm (Figure 1 A-B. The management course was complicated with prolonged respiratory failure, persistent infection, despite negative cultures and extended hospital stay. After 50 days of slow recovery the patient was discharged with a need for home oxygen therapy. Ten days later, he was re-admitted with chest pain requiring admission to the coronary care unit where severe pulmonary hypertension was diagnosed with Doppler echocardiography. Troponin-T was mildly elevated, 1,3 ug/L (ref <0,01, CRP was 50 mg/L and chest X-ray showed bilateral lung infiltrates and wide pulmonary vessels. At this point a systo-diastolic murmur was heard at the left lower sternal edge. With a view of potential coronary reintervention and to evaluate the pulmonary hypertension, a coronary angiogram and a pulmonary artery cathetherisation were performed. This showed a new stenosis in the left anterior descending coronary artery and the pulmonary catheterisation showed a “step-up” in oxygen saturation in the pulmonary artery, suggesting a left-to-right shunt. The vein graft aneurysm did not contribute to the coronary circulation. A cardiovascular magnetic resonance scan revealed a communication between the vein graft aneurysm and the left branch pulmonary artery

  12. Celiac Trunk Embolization, as a Means of Elongating Short Distal Descending Thoracic Aortic Aneurysm Necks, Prior to Endovascular Aortic Repair

    International Nuclear Information System (INIS)

    Belenky, Alexander; Haddad, Menashe; Idov, Igor; Knizhnik, Michael; Litvin, Sergey; Bachar, Gil N.; Atar, Eli

    2009-01-01

    The purpose of this study was to report our experience in elongating short distal necks of descending thoracic aortic aneurysms (DTAAs) by coil embolization of the celiac trunk prior to endovascular aneurysm repair (EVAR). During 6 years seven patients (five men and two women; mean age, 74) who had DTAAs with short distal necks unsuitable for conventional EVAR, and well patent superior and inferior mesenteric arteries based on CT, were treated in one session with EVAR after the celiac trunk was coil embolized to elongate the neck. All patients were followed by CT every 3 months in the first year and every 6 months thereafter. Technical success was achieved in all patients, and no early or late ischemic complications were noted. No procedural complications occurred and good aneurysm sealing was obtained in all patients. Three endoleaks were identified after 3 months (one patient) and 6 months (two patients); all were treated successfully with insertion of an additional stent-graft. In patients with DTAAs who are candidates for EVAR but have short aneurysm distal necks, celiac trunk embolization-only if the superior and inferior mesenteric arteries are patent-is a good and safe way to elongate the neck and enable EVAR.

  13. Value of three-dimensional computed tomography in screening cerebral aneurysms

    Energy Technology Data Exchange (ETDEWEB)

    Yamaguchi, Tamaki; Sugiura, Yusuke; Suzuki, Atsushi; Yamagata, Yoshitaka [Hyogo Medical Coll. (Japan)

    1997-10-01

    We performed three-dimensional computed tomography (3D-CT) in 6 patients of cerebral aneurysm. Prior cerebral angiography showed a total of 17 aneurysms. 3D-CT alone detected 10 cerebral aneurysm (59%). It was possible to identify aneurysms larger than 10 mm even when located near the circle of Willis. It was difficult to identify aneurysms when smaller than 7 mm regardless of their location. 3D-CT was of limited value in detecting cerebral aneurysms, particularly when located near the circle of Willis with complex vascular network. As cases of oculomotor palsy may be caused by lesions other than cerebral aneurysm, we advocate that 3D-CT be performed after magnetic resonance imaging (MRI) in screening cases of suspected cerebral aneurysm. (author)

  14. Spontaneous non aneurysmal subarachnoid hemorrhage

    International Nuclear Information System (INIS)

    Bian Jieyong; Wang Zhong; Zhou Dai

    2000-01-01

    Objective: To study the etiology and the treatment of spontaneous non-aneurysmal subarachnoid hemorrhage. Methods: Twenty five cases of cerebral vessel angiography negative patients were analysed retrospectively, the majority of them had been undergone CT, DSA, MRI examination in order to define the etiological factor. Results: Among them, there was 1 case of spinal arteria-vena malformation, 1 case of hemorrhagic blood and 2 cases according to the revealing of MRI could be explained as bled vascular-occult malformation or cavernous angioma. Conclusion: The management and prognosis of patients in whom non-aneurysm is founded on the initial angiogram depends on the pattern of hemorrhage of the initial CT scanning, repeated angiography should be avoided for the case of premise encephalic non-aneurysmal SAH and MRI examination may be indicated to defining of etiological factors

  15. Predicting target vessel location on robot-assisted coronary artery bypass graft using CT to ultrasound registration

    International Nuclear Information System (INIS)

    Cho, Daniel S.; Linte, Cristian; Chen, Elvis C. S.; Bainbridge, Daniel; Wedlake, Chris; Moore, John; Barron, John; Patel, Rajni; Peters, Terry

    2012-01-01

    Purpose: Although robot-assisted coronary artery bypass grafting (RA-CABG) has gained more acceptance worldwide, its success still depends on the surgeon's experience and expertise, and the conversion rate to full sternotomy is in the order of 15%-25%. One of the reasons for conversion is poor pre-operative planning, which is based solely on pre-operative computed tomography (CT) images. In this paper, the authors propose a technique to estimate the global peri-operative displacement of the heart and to predict the intra-operative target vessel location, validated via both an in vitro and a clinical study. Methods: As the peri-operative heart migration during RA-CABG has never been reported in the literatures, a simple in vitro validation study was conducted using a heart phantom. To mimic the clinical workflow, a pre-operative CT as well as peri-operative ultrasound images at three different stages in the procedure (Stage 0 --following intubation; Stage 1 --following lung deflation; and Stage 2 --following thoracic insufflation) were acquired during the experiment. Following image acquisition, a rigid-body registration using iterative closest point algorithm with the robust estimator was employed to map the pre-operative stage to each of the peri-operative ones, to estimate the heart migration and predict the peri-operative target vessel location. Moreover, a clinical validation of this technique was conducted using offline patient data, where a Monte Carlo simulation was used to overcome the limitations arising due to the invisibility of the target vessel in the peri-operative ultrasound images. Results: For the in vitro study, the computed target registration error (TRE) at Stage 0 , Stage 1 , and Stage 2 was 2.1, 3.3, and 2.6 mm, respectively. According to the offline clinical validation study, the maximum TRE at the left anterior descending (LAD) coronary artery was 4.1 mm at Stage 0 , 5.1 mm at Stage 1 , and 3.4 mm at Stage 2 . Conclusions: The authors

  16. Magnetic resonance imaging of large and giant intracranial aneurysms

    Energy Technology Data Exchange (ETDEWEB)

    Matsumura, Kenichi; Saito, Akira; Nakasu, Yoko; Matsuda, Masayuki; Handa, Jyoji [Shiga University of Medical Science, Shiga (Japan); Todo, Giro

    1990-06-01

    Twelve large or giant intracranial aneurysms were studied with magnetic resonance (MR) imaging, and the findings were compared with those from computed tomographic (CT) scanning. Characteristic MR features of such aneurysms are: round, extra-axial mass with hypointensity rim; signal void, paradoxical enhancement, or even-echo rephasing due to blood flow; and laminated, eccentric thrombus with increased signal intensity when fresh, perianeurysmal hemorrhage occurs in the acute or subacute stage after aneurysmal rupture. MR imaging, however, often fails to identify or characterize the area of calcification. For the diagnosis of large or giant intracranial aneurysms, MR imaging is apparently superior to CT scanning in differentiating aneurysms from tumors, delineating the blood flow and intraluminal thrombus, and detecting the exact size of the aneurysm. It may also provide useful information concerning the growth mechanisms of aneurysms with or without thrombus formation. (author).

  17. Current management of inguinal false aneurysms

    DEFF Research Database (Denmark)

    Houlind, Kim; Jepsen, Jørn M; Saicu, Cristian

    2017-01-01

    False aneurysms are formed as a result of bleeding causing a hematoma to compress the surrounding tissue. The majority of false aneurysms presenting to the vascular surgeon are caused by iatrogenic injury to an artery. Although anastomotic failure occurs, a much higher number is caused by bleeding...... vessels. endovascular treatment with coils or covered stent grafts have proven useful in infected ilio-femoral false aneurysms. Open surgical repair may be the best treatment in the setting of imminent rupture, massive haematoma and skin necrosis. We present three patient cases treated with open surgery...

  18. Clinical validation of a software for quantitative follow-up of abdominal aortic aneurysm maximal diameter and growth by CT angiography

    International Nuclear Information System (INIS)

    Kauffmann, Claude; Tang, An; Dugas, Alexandre; Therasse, Eric; Oliva, Vincent; Soulez, Gilles

    2011-01-01

    Purpose: To compare the reproducibility and accuracy of abdominal aortic aneurysm (AAA) maximal diameter (D-max) measurements using segmentation software, with manual measurement on double-oblique MPR as a reference standard. Materials and methods: The local Ethics Committee approved this study and waived informed consent. Forty patients (33 men, 7 women; mean age, 72 years, range, 49-86 years) had previously undergone two CT angiography (CTA) studies within 16 ± 8 months for follow-up of AAA ≥35 mm without previous treatment. The 80 studies were segmented twice using the software to calculate reproducibility of automatic D-max calculation on 3D models. Three radiologists reviewed the 80 studies and manually measured D-max on double-oblique MPR projections. Intra-observer and inter-observer reproducibility were calculated by intraclass correlation coefficient (ICC). Systematic errors were evaluated by linear regression and Bland-Altman analyses. Differences in D-max growth were analyzed with a paired Student's t-test. Results: The ICC for intra-observer reproducibility of D-max measurement was 0.992 (≥0.987) for the software and 0.985 (≥0.974) and 0.969 (≥0.948) for two radiologists. Inter-observer reproducibility was 0.979 (0.954-0.984) for the three radiologists. Mean absolute difference between semi-automated and manual D-max measurements was estimated at 1.1 ± 0.9 mm and never exceeded 5 mm. Conclusion: Semi-automated software measurement of AAA D-max is reproducible, accurate, and requires minimal operator intervention.

  19. Blood pressure shifts resulting from a concealed arteriovenous fistula associated with an iliac aneurysm: a case report.

    Science.gov (United States)

    Doi, Shintaro; Motoyama, Yoshiaki; Ito, Hiromi

    2016-01-01

    A solitary iliac aneurysm (SIA) is more uncommon than an abdominal aortic aneurysm. The aneurysm is located in the deep pelvis and is diagnosed when it reaches a large size with symptoms of compression around adjacent structures and organs or when it ruptures. A definite diagnosis of an arteriovenous fistula (AVF) associated with a SIA is difficult preoperatively because there might not be enough symptoms and time for diagnosis. Here, we present a patient with asymptomatic rupture of SIA into the common iliac vein with characteristic blood pressure shifts. A 41-year-old man with a huge SIA underwent aortobifemoral graft replacement. Preoperatively, his blood pressure showed characteristic shifts for one or two heartbeats out of five beats, indicating that an AVF was present and that the shunt was about to having a high flow. During surgery, an AVF associated with the SIA was found to be concealed owing to compression from the huge iliac artery aneurysm, and the shunt showed a high flow, resulting in shock during the surgery. No complications were noted after aortobifemoral graft replacement. Postoperatively, we noted an enhanced paravertebral vein on computed tomography (CT), which indicated the presence of an AVF. Definite diagnosis of an AVF offers advantages in surgical and anesthetic management. We emphasize that a large SIA can push the iliac vein and occlude an AVF laceration, concealing the enhancement of the veins in the arterial phase on CT. Blood pressure shifts might predict the existence of a concealed AVF that has a large shunt. Even if the vena cava and the iliac veins are not enhanced on CT, anesthesiologists should carefully determine whether their distal branches are enhanced.

  20. [False aneurysm on dacron prosthesis, 20 years after aortofemoral bypass].

    Science.gov (United States)

    Illuminati, G; Bertagni, A; Nasti, A G; Montesano, G

    2001-10-01

    A 85-year-old male developed a false, non septic, non anastomotic aneurysm, 20 years after right aorto-femoral Dacron grafting for claudication. On account of the proximity to the femoral anastomosis, and the association with a profunda femoris stenosis, a conventional surgical repair was preferred to an endovascular treatment. The patient underwent a successful aneurysm resection followed by PTFE interposition between the primary graft and the profunda femoris artery, with uneventful recovery.

  1. The value of MDCT in diagnosis of splenic artery aneurysms

    International Nuclear Information System (INIS)

    Sun Cong; Liu Cheng; Wang Ximing; Wang Daoping

    2008-01-01

    Objective: To evaluate the clinical value of multiple detector computed tomography (MDCT) in the diagnosis and planning the treatment of splenic aneurysms. Methods: Eight cases with splenic artery aneurysms (SAA) were retrospectively reviewed. Sixty four-slice spiral CT scans were performed. Intravenous contrast material was injected at 4 ml/s, and arterial and venous phase images were obtained. Subsequently, arterial phase images were analyzed and made for CT angiography. The diagnosis was made by using axial and reconstructive images. All of the patients were also performed Doppler color echocardiography. Results: All patients showed splenic artery and splenic artery aneurysms clearly with CT arterial phase images. Among them, six patients had splenic artery aneurysms, one had giant splenic artery aneurysms (GSAA) and one had splenic artery pseudoaneurysms. Ultrasound examination only diagnosed six of them. Conclusion: MDCT is a noninvasive and valuable method in diagnosis of splenic artery aneurysms and has high value in determination of treatment plan

  2. The value of MDCT in diagnosis of splenic artery aneurysms

    Energy Technology Data Exchange (ETDEWEB)

    Sun Cong [Shandong University, Shandong Provincial Medical Imaging Institute, Road jing-wu No. 324, Jinan, Shandong 250021 (China)], E-mail: suncong03@163.com; Liu Cheng; Wang Ximing; Wang Daoping [Shandong University, Shandong Provincial Medical Imaging Institute, Road jing-wu No. 324, Jinan, Shandong 250021 (China)

    2008-03-15

    Objective: To evaluate the clinical value of multiple detector computed tomography (MDCT) in the diagnosis and planning the treatment of splenic aneurysms. Methods: Eight cases with splenic artery aneurysms (SAA) were retrospectively reviewed. Sixty four-slice spiral CT scans were performed. Intravenous contrast material was injected at 4 ml/s, and arterial and venous phase images were obtained. Subsequently, arterial phase images were analyzed and made for CT angiography. The diagnosis was made by using axial and reconstructive images. All of the patients were also performed Doppler color echocardiography. Results: All patients showed splenic artery and splenic artery aneurysms clearly with CT arterial phase images. Among them, six patients had splenic artery aneurysms, one had giant splenic artery aneurysms (GSAA) and one had splenic artery pseudoaneurysms. Ultrasound examination only diagnosed six of them. Conclusion: MDCT is a noninvasive and valuable method in diagnosis of splenic artery aneurysms and has high value in determination of treatment plan.

  3. Morphological parameters associated with ruptured posterior communicating aneurysms.

    Science.gov (United States)

    Ho, Allen; Lin, Ning; Charoenvimolphan, Nareerat; Stanley, Mary; Frerichs, Kai U; Day, Arthur L; Du, Rose

    2014-01-01

    The rupture risk of unruptured intracranial aneurysms is known to be dependent on the size of the aneurysm. However, the association of morphological characteristics with ruptured aneurysms has not been established in a systematic and location specific manner for the most common aneurysm locations. We evaluated posterior communicating artery (PCoA) aneurysms for morphological parameters associated with aneurysm rupture in that location. CT angiograms were evaluated to generate 3-D models of the aneurysms and surrounding vasculature. Univariate and multivariate analyses were performed to evaluate morphological parameters including aneurysm volume, aspect ratio, size ratio, distance to ICA bifurcation, aneurysm angle, vessel angles, flow angles, and vessel-to-vessel angles. From 2005-2012, 148 PCoA aneurysms were treated in a single institution. Preoperative CTAs from 63 patients (40 ruptured, 23 unruptured) were available and analyzed. Multivariate logistic regression revealed that smaller volume (p = 0.011), larger aneurysm neck diameter (0.048), and shorter ICA bifurcation to aneurysm distance (p = 0.005) were the most strongly associated with aneurysm rupture after adjusting for all other clinical and morphological variables. Multivariate subgroup analysis for patients with visualized PCoA demonstrated that larger neck diameter (p = 0.018) and shorter ICA bifurcation to aneurysm distance (p = 0.011) were significantly associated with rupture. Intracerebral hemorrhage was associated with smaller volume, larger maximum height, and smaller aneurysm angle, in addition to lateral projection, male sex, and lack of hypertension. We found that shorter ICA bifurcation to aneurysm distance is significantly associated with PCoA aneurysm rupture. This is a new physically intuitive parameter that can be measured easily and therefore be readily applied in clinical practice to aid in the evaluation of patients with PCoA aneurysms.

  4. Endovascular treatment of thoracic aorta aneurysm and dissection

    International Nuclear Information System (INIS)

    Petrov, I.; Stankov, Z.; Stefanov, St.; Stoyanov, Hr.

    2015-01-01

    Full text: The aim is to give up to date information about modern endovascular treatment of aortic pathology Dissection and aneurysms of the aorta are life threatening condition requiring in most of the cases prompt surgical or endovascular treatment because of the poor natural evolution. Purpose: to assess the immediate and 1-year outcome of endovascular treatment in broad spectrum of acute and subacute aortic syndrome during the last 3 years (November 2012 - August 2015) in City Clinic (Sofia, Bulgaria). We performed endovascular treatment of 47 patients (43 men, 4 women) at average age 54 y. with dissection (24) and aneurysms (23) of the aortic arch and thoracic aorta (in 5 emergent treatment was performed for aortic rupture). All patients were treated with minimal surgical femoral approach. In 4 (9%) of them initial carotid to carotid bypass was performed in order to provide a sufficient landing zone for the endograft implantation.the last 9 patients (19%) were treated without general anesthesia with either deep sedation or epidural anesthesia. Results: In all patients successful endograft implantation was achieved. Additional stent-graft or open cell stent was implanted in 4 cases in order to centralize the flow in the compressed true lumen. In 5 cases additional vascular plug or large coil was delivered in the left subclavian arteryostium in order to interrupt retrograde aneurysm or false lumen filling. Complications: 30 days mortality-2.2%, neurologic disorders (4.4%). one year survival- 45 (90.5%). 3 and 6 mo control CT scan showed no migration of the graft in 100%, full false lumen isolation in 19 out of 24 dissections (80%) and aneurysm free of expansion in 20 out of 23 (86%), patent carotid bay-pass graft in 4 of 4 (100%). This one center study showed excellent immediate and 1 year clinical and device results from endovascular repair of potentially fatal disease. Endovascular treatment is a method of choice for broad spectrum of aortic pathology

  5. Multidetector CT angiography as a noninvasive tool to assess graft patency of surgically reconstructed diffusely diseased coronary arteries

    Directory of Open Access Journals (Sweden)

    Ahmed I. Rezk

    2014-03-01

    Conclusion: Extensive reconstruction of the diffusely diseased LAD using an ITA graft could be performed safely with very encouraging results. MDCT angiography is an excellent non invasive tool not only to evaluate graft patency in the reconstructed LAD but also to detect other findings in asymptomatic patients with diffuse coronary artery disease for better and more close follow up.

  6. Acute contained ruptured aortic aneurysm presenting as left vocal fold immobility.

    Science.gov (United States)

    Gnagi, Sharon H; Howard, Brittany E; Hoxworth, Joseph M; Lott, David G

    2015-01-01

    Objective. To recognize intrathoracic abnormalities, including expansion or rupture of aortic aneurysms, as a source of acute onset vocal fold immobility. Methods. A case report and review of the literature. Results. An 85-year-old female with prior history of an aortic aneurysm presented to a tertiary care facility with sudden onset hoarseness. On laryngoscopy, the left vocal fold was immobile in the paramedian position. A CT scan obtained that day revealed a new, large hematoma surrounding the upper descending aortic stent graft consistent with an acute contained ruptured aortic aneurysm. She was referred to the emergency department for evaluation and treatment by vascular surgery. She was counseled regarding surgical options and ultimately decided not to pursue further treatment. Her vocal fold immobility was subsequently treated via office-based injection medialization two weeks after presentation and again 5 months after the initial injection which dramatically improved her voice. Follow-up CT scan at 8 months demonstrated a reduction of the hematoma. The left vocal cord remains immobile to date. Conclusion. Ortner's syndrome, or cardiovocal syndrome, is hoarseness secondary to left recurrent laryngeal nerve palsy caused by cardiovascular pathology. It is a rare condition and, while typically presenting gradually, may also present with acute symptomatology.

  7. Acute Contained Ruptured Aortic Aneurysm Presenting as Left Vocal Fold Immobility

    Directory of Open Access Journals (Sweden)

    Sharon H. Gnagi

    2015-01-01

    Full Text Available Objective. To recognize intrathoracic abnormalities, including expansion or rupture of aortic aneurysms, as a source of acute onset vocal fold immobility. Methods. A case report and review of the literature. Results. An 85-year-old female with prior history of an aortic aneurysm presented to a tertiary care facility with sudden onset hoarseness. On laryngoscopy, the left vocal fold was immobile in the paramedian position. A CT scan obtained that day revealed a new, large hematoma surrounding the upper descending aortic stent graft consistent with an acute contained ruptured aortic aneurysm. She was referred to the emergency department for evaluation and treatment by vascular surgery. She was counseled regarding surgical options and ultimately decided not to pursue further treatment. Her vocal fold immobility was subsequently treated via office-based injection medialization two weeks after presentation and again 5 months after the initial injection which dramatically improved her voice. Follow-up CT scan at 8 months demonstrated a reduction of the hematoma. The left vocal cord remains immobile to date. Conclusion. Ortner’s syndrome, or cardiovocal syndrome, is hoarseness secondary to left recurrent laryngeal nerve palsy caused by cardiovascular pathology. It is a rare condition and, while typically presenting gradually, may also present with acute symptomatology.

  8. Bilateral Distal Anterior Cerebral Artery Aneurysms Mimicking So-called "Kissing Aneurysms": A Case Report

    OpenAIRE

    山口, 竜一; 伊藤, 宣行; 前村, 栄治; 塩川, 芳昭; 齋藤, 勇; Ryuichi, YAMAGUCHI; Nobuyuki, ITO; Eiji, MAEMURA; Yoshiaki, SHIOKAWA; Isamu, SAITO; 公立阿伎留病院脳神経外科; 公立阿伎留病院脳神経外科; 公立阿伎留病院脳神経外科; 杏林大学医学部脳神経外科; 杏林大学医学部脳神経外科

    2003-01-01

    A 71-year-old woman presented disturbance of consciousness due to subarachnoid hemorrhage (SAH). A computed tomography (CT) on admission revealed diffuse thick SAH and intracerebral hematoma in the right frontal lobe. Conventional angiography and three-dimensional CT angiography showed symmetrical aneurysms located on the bilateral pericallosal arteries at bifurcation of the callosomarginal arteries. The operation was performed on the next day after onset of SAH. The aneurysms were clipped vi...

  9. Accuracy of Estimation of Graft Size for Living-Related Liver Transplantation: First Results of a Semi-Automated Interactive Software for CT-Volumetry

    Science.gov (United States)

    Mokry, Theresa; Bellemann, Nadine; Müller, Dirk; Lorenzo Bermejo, Justo; Klauß, Miriam; Stampfl, Ulrike; Radeleff, Boris; Schemmer, Peter; Kauczor, Hans-Ulrich; Sommer, Christof-Matthias

    2014-01-01

    Objectives To evaluate accuracy of estimated graft size for living-related liver transplantation using a semi-automated interactive software for CT-volumetry. Materials and Methods Sixteen donors for living-related liver transplantation (11 male; mean age: 38.2±9.6 years) underwent contrast-enhanced CT prior to graft removal. CT-volumetry was performed using a semi-automated interactive software (P), and compared with a manual commercial software (TR). For P, liver volumes were provided either with or without vessels. For TR, liver volumes were provided always with vessels. Intraoperative weight served as reference standard. Major study goals included analyses of volumes using absolute numbers, linear regression analyses and inter-observer agreements. Minor study goals included the description of the software workflow: degree of manual correction, speed for completion, and overall intuitiveness using five-point Likert scales: 1–markedly lower/faster/higher for P compared with TR, 2–slightly lower/faster/higher for P compared with TR, 3–identical for P and TR, 4–slightly lower/faster/higher for TR compared with P, and 5–markedly lower/faster/higher for TR compared with P. Results Liver segments II/III, II–IV and V–VIII served in 6, 3, and 7 donors as transplanted liver segments. Volumes were 642.9±368.8 ml for TR with vessels, 623.8±349.1 ml for P with vessels, and 605.2±345.8 ml for P without vessels (Pvolumetry performed with P can predict accurately graft size for living-related liver transplantation while improving workflow compared with TR. PMID:25330198

  10. Cardiac Computed Tomography (Multidetector CT, or MDCT)

    Science.gov (United States)

    ... Disease Venous Thromboembolism Aortic Aneurysm More Cardiac Computed Tomography (Multidetector CT, or MDCT) Updated:Sep 19,2016 What is Computerized Tomography (CT)? CT is a noninvasive test that uses ...

  11. Aneurysm growth after late conversion of thoracic endovascular aortic repair

    Directory of Open Access Journals (Sweden)

    Hirofumi Kasahara

    2015-01-01

    Full Text Available A 69-year-old man underwent thoracic endovascular aortic repair of a descending aortic aneurysm. Three years later, he developed impending rupture due to aneurysmal expansion that included the proximal landing zone. Urgent open surgery was performed via lateral thoracotomy, and a Dacron graft was sewn to the previous stent graft distally with Teflon felt reinforcement. Postoperatively, four sequential computed tomography scans demonstrated that the aneurysm was additionally increasing in size probably due to continuous hematoma production, suggesting a possibility of endoleaks. This case demonstrates the importance of careful radiologic surveillance after endovascular repair, and also after partial open conversion.

  12. Posttraumatic True Aneurysm of the Axillary Artery Following Blunt Trauma

    Directory of Open Access Journals (Sweden)

    Tugrul Goncu

    2010-01-01

    Full Text Available The majority of the axillary artery aneurysm cases arise as pseudoaneurysms secondary to blunt or iatrogenic trauma. Isolated traumatic true axillary artery aneurysm is a relatively unusual disorder and generally occurs with repetitive blunt trauma. A 22-year-old female patient with distal axillary artery true aneurysm due to simple blunt axillothoracic trauma is presented. The aneurysm was excised with subpectoral-axillary approach and saphenous vein graft interposition was applied. Long-term follow-up with the patient was uneventful.

  13. Micro CT and human histological analysis of a peri-implant osseous defect grafted with porous titanium granules: a case report.

    Science.gov (United States)

    Wohlfahrt, Johan Caspar; Aass, Anne Merete; Ronold, Hans Jacob; Lyngstadaas, Stale Petter

    2011-01-01

    Treatment of peri-implant osseous defects represents a significant challenge for clinicians, and the need to evolve within predictable surgical procedures is important. This case report describes the surgical treatment and grafting with porous titanium granules (PTG) of one patient with a peri-implant osseous defect. The suggested thrombogenic properties of titanium are intriguing from the perspective of osseous reconstructive surgery. In an ongoing randomized clinical trial using PTG for treatment of peri-implant osseous defects, one patient with one test implant was excluded and scheduled for implant removal. The surgical therapy included open flap debridement with surface decontamination with 24% EDTA gel, grafting with PTG, and resubmersion of the implant. After 12 months of healing, the implant with surrounding tissues was excised en bloc and micro CT and histological analyses were performed. Analyses showed PTG in close contact with new bone and with bone growing both into the porosities of the graft material and onto the adjacent implant surface. Element analysis demonstrated calcium and phosphorus in the new tissue embedding the PTG and the implant. Int J Oral Maxillofac Implants 2011;26:e9-e14.

  14. Traumatic intracranial aneurysm: a case report

    International Nuclear Information System (INIS)

    Kang, Si Won; Chun, Kyung Ah; Baik, Joon Hyun; Shin, Kyung Sub

    1994-01-01

    The occurrence of traumatic aneurysm is rare in head injury, but this complication is important as it is a potentially treatable cause delayed onset of intracranial hemorrhage. Authors report one case of traumatic aneurysm involving A1 and A2 junction of anterior cerebral artery. A-28-year-old man with traffic accident was examined with brain CT and cerebral angiography. 1) Brain CT: Initial scan shows multiple skull fractures involving right frontal bones with subarachnoid hemorrhage and pneumocephalus. Follow-up scan shows intracerebral hemorrhage at bilateral frontal lobes. 2) Cerebral angiography: A traumatic aneurysm which is slowly filling and delayed emptying is noted at the junctional portion of A1 and A2 segment of the anterior cerebral artery. This report demonstrates radiologic findings of traumatic aneurysm at anterior cerebral artery with the brief review of the literatures

  15. Endoport-Assisted Microsurgical Treatment of a Ruptured Periventricular Aneurysm

    Directory of Open Access Journals (Sweden)

    Ching-Jen Chen

    2016-01-01

    Full Text Available Background and Importance. Ruptured periventricular aneurysms in patients with moyamoya disease represent challenging pathologies. The most common methods of treatment include endovascular embolization and microsurgical clipping. However, rare cases arise in which the location and anatomy of the aneurysm make these treatment modalities particularly challenging. Clinical Presentation. We report a case of a 34-year-old female with moyamoya disease who presented with intraventricular hemorrhage. CT angiography and digital subtraction angiography revealed an aneurysm located in the wall of the atrium of the right lateral ventricle. Distal endovascular access was not possible, and embolization risked the sacrifice of arteries supplying critical brain parenchyma. Using the BrainPath endoport system, the aneurysm was able to be accessed. Since the fusiform architecture of the aneurysm prevented clip placement, the aneurysm was ligated with electrocautery. Conclusion. We demonstrate the feasibility of endoport-assisted approach for minimally invasive access and treatment of uncommon, distally located aneurysms.

  16. Accuracy of estimation of graft size for living-related liver transplantation: first results of a semi-automated interactive software for CT-volumetry.

    Directory of Open Access Journals (Sweden)

    Theresa Mokry

    Full Text Available To evaluate accuracy of estimated graft size for living-related liver transplantation using a semi-automated interactive software for CT-volumetry.Sixteen donors for living-related liver transplantation (11 male; mean age: 38.2±9.6 years underwent contrast-enhanced CT prior to graft removal. CT-volumetry was performed using a semi-automated interactive software (P, and compared with a manual commercial software (TR. For P, liver volumes were provided either with or without vessels. For TR, liver volumes were provided always with vessels. Intraoperative weight served as reference standard. Major study goals included analyses of volumes using absolute numbers, linear regression analyses and inter-observer agreements. Minor study goals included the description of the software workflow: degree of manual correction, speed for completion, and overall intuitiveness using five-point Likert scales: 1--markedly lower/faster/higher for P compared with TR, 2--slightly lower/faster/higher for P compared with TR, 3--identical for P and TR, 4--slightly lower/faster/higher for TR compared with P, and 5--markedly lower/faster/higher for TR compared with P.Liver segments II/III, II-IV and V-VIII served in 6, 3, and 7 donors as transplanted liver segments. Volumes were 642.9±368.8 ml for TR with vessels, 623.8±349.1 ml for P with vessels, and 605.2±345.8 ml for P without vessels (P<0.01. Regression equations between intraoperative weights and volumes were y = 0.94x+30.1 (R2 = 0.92; P<0.001 for TR with vessels, y = 1.00x+12.0 (R2 = 0.92; P<0.001 for P with vessels, and y = 1.01x+28.0 (R2 = 0.92; P<0.001 for P without vessels. Inter-observer agreement showed a bias of 1.8 ml for TR with vessels, 5.4 ml for P with vessels, and 4.6 ml for P without vessels. For the degree of manual correction, speed for completion and overall intuitiveness, scale values were 2.6±0.8, 2.4±0.5 and 2.CT-volumetry performed with P can predict accurately graft

  17. Aneurysmal malformation of the extrahepatic portal vein: a case report

    International Nuclear Information System (INIS)

    Lee, Jeong Min; Kang, Sung Soo; Kim, Chong Soo; Han, Hyeun Young

    1999-01-01

    Aneurysmal malformation of the portal vein is a rare entity. To our knowledge, only scattered reports of portal vein aneurysms appear in the literature in English, and there is no previously published report in Korean. We describe a case exhibiting aneurysmal malformation of the extrahepatic portal vein at the hepatic hilum ; the findings demonstrated by ultrasound, CT and angiography are discussed, a review of previously described cases is included

  18. Diagnosis of ruptured intracranial aneurysm in acute stage

    International Nuclear Information System (INIS)

    Yoshiyama, Masataka; Nakagawa, Toshifumi

    1980-01-01

    Subarachnoid hemorrhage at an acute stage within one day from the onset to the first CT scan was classified into subarachnoid hemorrhage secondary to intracranial aneurysm, subarachnoid hemorrhage of unknown origin and subarachnoid hemorrhage of which angiography could not be carried out, and the first CT findings, the severity, and the prognosis of these subarachnoid hemorrhage were compared and discussed. CT findings of subarachnoid hemorrhage secondary to intracranial aneurysm showed various changes according to progress in the severity with time, and intracranial hematoma, intraventricular clots and ventricular dilatation increased according to progress in the severity. Ruptured intracranial aneurysm in middle cerebral artery, anterior cerebral artery and anterior communicating artery could be found easily by CT, but that in internal carotid artery and vertabral basilar artery was difficult to be detected by CT. When cerebral angiography was carried out repeatedly for ruptured intracranial aneurysm of unknown origin, the time of performance must be consifered with attention to angiospasms or hematoma. (Tsunoda, M.)

  19. Endovascular therapy of abdominal aortic aneurysm: results of a mid-term follow-up

    International Nuclear Information System (INIS)

    Pitton, M.B.; Schweitzer, H.; Herber, S.; Thelen, M.; Schmiedt, W.; Neufang, A.; Dueber, C.

    2003-01-01

    Prospective study to evaluate clinical results and complications of endovascular abdominal aortic aneurysm treatment in a mid-term follow-up. Materials and methods: A total of 122 patients (9 females, 113 males, average age 70.0±7,9 years) with abdominal aortic aneurysms were treated with stent grafts (53 Vanguard or Stentor endografts, 69 Talent endografts). Group I consisted of 40 patients who had all aortic tributaries of the aneurysm sac occluded prior to endovalscular grafting, either spontaneously by parietal thrombosis or by selective coil embolization of the respective ostia preserving collateral circulation distal to the vessel occlusion. Group II consisted of 82 patients and included all cases without or with incomplete coil embolization with at least one patent vessel. Stent grafting was performed in general anesthesia in the first 21 patients, followed by peridural anesthesia in 15 cases, and local anesthesia with conscious sedation in 86 cases. The results were evaluated with Spiral-CT, MRI and radiographs of the endovascular graft, with follow-up examinations obtained at 3, 6, 12 months, and every year - Implantation was successfully completed in all cases without primary conversion surgery, laparotomy or any significant complication. Mean follow-up was 29±21 months (maximum 82 months). The 30-day mortality was 0,8% due to a myocardial infarction 3 days after discharge from the hospital. A total of 47 re-interventions were performed in 29 patients (23.8%), with 35 re-interventions in 18 cases with Vanguard or Stentor endografts and 12 re-interventions in 11 patients with Talent endografts. 23 percutaneous re-interventions included distal graft extension (n=11), Wallstent for kinking and limb stenosis (n=3), and secondary coil embolization of collateral vessels (n=9). 24 surgical re-interventions included proximal graft extension (n=6), new endovascular grafts (n=3), surgical clipping of lumbar and mesenteric artery branches for type-II endoleaks

  20. Aneurysm in the brain

    Science.gov (United States)

    ... gov/ency/article/001414.htm Aneurysm in the brain To use the sharing features on this page, ... aneurysm occurs in a blood vessel of the brain, it is called a cerebral, or intracranial, aneurysm. ...

  1. Brain aneurysm repair - discharge

    Science.gov (United States)

    ... this page: //medlineplus.gov/ency/patientinstructions/000123.htm Brain aneurysm repair - discharge To use the sharing features ... this page, please enable JavaScript. You had a brain aneurysm . An aneurysm is a weak area in ...

  2. Aneurysm Complications

    Science.gov (United States)

    ... Susco Chair of Research North Shore University Hospital, Brain Aneurysm Center Chair of Research The Christopher C. Getch, MD Chair of Research Carol W. Harvey Memorial Chair of Research Kristen’s Legacy of Love Chair of Research TeamCindy Alcatraz Chair of Research ...

  3. 18F-FDG uptake assessed by PET/CT in abdominal aortic aneurysms is associated with cellular and molecular alterations prefacing wall deterioration and rupture.

    Science.gov (United States)

    Courtois, Audrey; Nusgens, Betty V; Hustinx, Roland; Namur, Gauthier; Gomez, Pierre; Somja, Joan; Defraigne, Jean-Olivier; Delvenne, Philippe; Michel, Jean-Baptiste; Colige, Alain C; Sakalihasan, Natzi

    2013-10-01

    Rupture of abdominal aortic aneurysms (AAAs) leads to a significant morbidity and mortality in aging populations, and its prediction would be most beneficial to public health. Spots positive for uptake of (18)F-FDG detected by PET are found in 12% of AAA patients (PET+), who are most often symptomatic and at high rupture risk. Comparing the (18)F-FDG-positive site with a negative site from the same aneurysm and with samples collected from AAA patients with no (18)F-FDG uptake should allow the discrimination of biologic alterations that would help in identifying markers predictive of rupture. Biopsies of the AAA wall were obtained from patients with no (18)F-FDG uptake (PET0, n = 10) and from PET+ patients (n = 8), both at the site positive for uptake and at a distant negative site of the aneurysmal wall. Samples were analyzed by immunohistochemistry, quantitative real-time polymerase chain reaction, and zymography. The sites of the aneurysmal wall with a positive (18)F-FDG uptake were characterized by a strikingly increased number of adventitial inflammatory cells, highly proliferative, and by a drastic reduction of smooth muscle cells (SMCs) in the media as compared with their negative counterpart and with the PET0 wall. The expression of a series of genes involved in the maintenance and remodeling of the wall was significantly modified in the negative sites of PET+, compared with the PET0 wall, suggesting a systemic alteration of the aneurysmal wall. Furthermore, a striking increase of several matrix metalloproteinases (MMPs), notably the MMP1 and MMP13 collagenases, was observed in the positive sites, mainly in the adventitia. Moreover, PET+ patients were characterized by a higher circulating C-reactive protein. Positive (18)F-FDG uptake in the aneurysmal wall is associated with an active inflammatory process characterized by a dense infiltrate of proliferating leukocytes in the adventitia and an increased circulating C-reactive protein. Moreover, a loss of SMC

  4. The multidetector computed tomography angiography (MDCTA) in the diagnosis of splenic artery aneurysm and pseudoaneurysm

    International Nuclear Information System (INIS)

    Saba, Luca; Mallarini, Giorgio; Anzidei, Michele; Lucatelli, Pierleone

    2011-01-01

    Splenic artery aneurysm is the most frequent visceral artery aneurysm and rupture of the aneurysm is associated with a high mortality rate. It is important to discriminate between a true aneurysm and a pseudoaneurysm that may be caused by pancreatitis, iatrogenic and postoperative causes, trauma and peptic ulcer disease. Multidetector-row CT angiography (MDCTA) allows detailed visualization of the vascular anatomy and may allow identification of aneurysms and pseudoaneurysms that affect the splenic artery. The objective of this article is to provide a review of the general characteristics of splenic artery aneurysms and pseudoaneurysms and to describe the findings of MDCTA

  5. The multidetector computed tomography angiography (MDCTA) in the diagnosis of splenic artery aneurysm and pseudoaneurysm

    Energy Technology Data Exchange (ETDEWEB)

    Saba, Luca; Mallarini, Giorgio (Dept. of Radiology, Azienda Ospedaliero Universitaria (AOU), Cagliari (Italy)), email: lucasaba@tiscali.it; Anzidei, Michele; Lucatelli, Pierleone (Dept. of Radiological Sciences, Univ. of Rome La Sapienza, Rome (Italy))

    2011-06-15

    Splenic artery aneurysm is the most frequent visceral artery aneurysm and rupture of the aneurysm is associated with a high mortality rate. It is important to discriminate between a true aneurysm and a pseudoaneurysm that may be caused by pancreatitis, iatrogenic and postoperative causes, trauma and peptic ulcer disease. Multidetector-row CT angiography (MDCTA) allows detailed visualization of the vascular anatomy and may allow identification of aneurysms and pseudoaneurysms that affect the splenic artery. The objective of this article is to provide a review of the general characteristics of splenic artery aneurysms and pseudoaneurysms and to describe the findings of MDCTA

  6. Inflammatory aneurysms of the abdominal aorta

    International Nuclear Information System (INIS)

    Cilotti, A.; Bagnolesi, P.; Cigoni, R.; Bimbi, M; Bartolozzi, C.

    1991-01-01

    The authors report their experience with US and CT in 31 cases of inflammatory aneurysms out of a study population of 200 patients with abdominal aortic aneurysms. The work started with a case that had not been diagnosed at US, either due to the operator's poor knowledge of this pathologic condition or because of improper examination tecnique. The authors stress the importance of a highfrequency probe and proper gain settings which are often necessary for a good visualization of the anterior aortic wall. The correct diagnosis of the inflammatory nature of the aneurysm has been assessed by US ever since, in all cases except for very obese and meteoric patients. in our series, US diagnostic accuracy was 78% versus 33% reported in literature. US was not accurate in evaluating adjacent structures involvement within fibrous tissues (ureteral narrowing, caval narrowing)-which CT did. Neither US nor CT exhibited reliable diagnostic accuracy in demonstrating enteric involvement within fibrous tissues

  7. Stereoscopy in diagnostic radiology and procedure planning: does stereoscopic assessment of volume-rendered CT angiograms lead to more accurate characterisation of cerebral aneurysms compared with traditional monoscopic viewing?

    International Nuclear Information System (INIS)

    Stewart, Nikolas; Lock, Gregory; Coucher, John; Hopcraft, Anthony

    2014-01-01

    Stereoscopic vision is a critical part of the human visual system, conveying more information than two-dimensional, monoscopic observation alone. This study aimed to quantify the contribution of stereoscopy in assessment of radiographic data, using widely available three-dimensional (3D)-capable display monitors by assessing whether stereoscopic viewing improved the characterisation of cerebral aneurysms. Nine radiology registrars were shown 40 different volume-rendered (VR) models of cerebral computed tomography angiograms (CTAs), each in both monoscopic and stereoscopic format and then asked to record aneurysm characteristics on short multiple-choice answer sheets. The monitor used was a current model commercially available 3D television. Responses were marked against a gold standard of assessments made by a consultant radiologist, using the original CT planar images on a diagnostic radiology computer workstation. The participants' results were fairly homogenous, with most showing no difference in diagnosis using stereoscopic VR models. One participant performed better on the monoscopic VR models. On average, monoscopic VRs achieved a slightly better diagnosis by 2.0%. Stereoscopy has a long history, but it has only recently become technically feasible for stored cross-sectional data to be adequately reformatted and displayed in this format. Scant literature exists to quantify the technology's possible contribution to medical imaging - this study attempts to build on this limited knowledge base and promote discussion within the field. Stereoscopic viewing of images should be further investigated and may well eventually find a permanent place in procedural and diagnostic medical imaging.

  8. Advances in open microsurgery for cerebral aneurysms.

    Science.gov (United States)

    Davies, Jason M; Lawton, Michael T

    2014-02-01

    Endovascular techniques introduced strong extrinsic forces that provoked reactive changes in aneurysm surgery. Microsurgery has become less invasive, more appealing to patients, lower risk, and efficacious for complex aneurysms, particularly those unfavorable for or failing endovascular therapy. To review specific advances in open microsurgery for aneurysms. A university-based, single-surgeon practice was examined for the use of minimally invasive craniotomies, surgical management of recurrence after coiling, the use of intracranial-intracranial bypass techniques, and cerebrovascular volume-outcome relationships. The mini-pterional, lateral supraorbital, and orbital-pterional craniotomies are minimally invasive alternatives to standard craniotomies. Mini-pterional and lateral supraorbital craniotomies were used in one-fourth of unruptured patients, increasing from 22% to 28%, whereas 15% of patients underwent orbital-pterional craniotomies and trended upward from 11% to 20%. Seventy-four patients were treated for coil recurrences (2.3% of all aneurysms) with direct clip occlusion (77%), clip occlusion after coil extraction (7%), or parent artery occlusion with bypass (16%). Intracranial-intracranial bypass (in situ bypass, reimplantation, reanastomosis, and intracranial grafts) transformed the management of giant aneurysms and made the surgical treatment of posterior inferior cerebellar artery aneurysms competitive with endovascular therapy. Centralization maximized the volume-outcome relationships observed with clipping. Aneurysm microsurgery has embraced minimalism, tailoring the exposure to the patient's anatomy with the smallest possible craniotomy that provides adequate exposure. The development of intracranial-intracranial bypasses is an important advancement that makes microsurgery a competitive option for complex and recurrent aneurysms. Trends toward centralizing aneurysm surgery in tertiary centers optimize results achievable with open microsurgery.

  9. Early aneurysmal degeneration of femoral vein conduit used for aortoiliac reconstruction in a child

    Directory of Open Access Journals (Sweden)

    Zakariyae Bouziane, MD

    2016-09-01

    Full Text Available We report the case of a 14-year-old boy who underwent an aortobi-iliac bypass with a femoral vein graft. The patient presented with early aneurysmal degeneration of the entire venous graft only 11 months later. He was treated successfully with redo abdominal aortic surgery and a bifurcated Dacron graft.

  10. Coil embolization of mycotic pulmonary artery aneurysm: a case report

    International Nuclear Information System (INIS)

    Kim, Jeen Woo; Lee, Jae Kyo; Hwang, Mi Soo; Cho, Kil Ho

    2000-01-01

    Aneurysms of the pulmonary artery are rare, with mycotic aneurysms occurring most frequently. This latter type may also occur in association with a lung abscess or septicemia, particularly in drug addicts. As far as we are aware, the radiologic findings of mycotic aneurysm of the pulmanary artery have not been reported in Korea. We present the simple chest radiographs, as well as the CT and angiographic findings, of a case of aneurysm of the pulmonary artery which was successfully embolized using a coil. (author)

  11. Coil embolization of mycotic pulmonary artery aneurysm: a case report

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Jeen Woo; Lee, Jae Kyo; Hwang, Mi Soo; Cho, Kil Ho [College of Medicine, Yeungnam University, Taegu (Korea, Republic of)

    2000-02-01

    Aneurysms of the pulmonary artery are rare, with mycotic aneurysms occurring most frequently. This latter type may also occur in association with a lung abscess or septicemia, particularly in drug addicts. As far as we are aware, the radiologic findings of mycotic aneurysm of the pulmanary artery have not been reported in Korea. We present the simple chest radiographs, as well as the CT and angiographic findings, of a case of aneurysm of the pulmonary artery which was successfully embolized using a coil. (author)

  12. Traumatic aneurysms of the pericallosal arteries

    International Nuclear Information System (INIS)

    Nakstad, P.; Nornes, H.; Hauge, H.N.

    1986-01-01

    Of a total of 912 operated intracranial aneurysms only three were classified as traumatic (0.3%). They were found in children after severe head trauma and were all located on the pericallosal artery or its branches and not a bifurcations. Shearing forces between the falx, the arteries and the brain at the time of injury are held responsible for the development of these aneurysms. Unlike these traumatic aneurysms, 29 ''spontaneous'' pericallosal aneurysms (3.2%) in adults were located at the bifurcations of the artery. As significantly fewer reports of traumatic aneurysms have been published during the last decade than before 1976, it is suggested that some might have been overlooked as a consequence of CT replacing cerebral angiography in the neuroradiological evaluation of severe head injury. This possibility should be kept in mind, especially when dealing with children after head injury and when CT scans indicate brain damage around the falx. The possibility of overlooking traumatic pericallosal aneurysms is described by other authors and discussed further in this paper. (orig.)

  13. The use of light/chemically hardened polymethylmethacrylate, polyhydroxylethylmethacrylate, and calcium hydroxide graft material in combination with polyanhydride around implants and extraction sockets in minipigs: Part II: histologic and micro-CT evaluations.

    Science.gov (United States)

    Hasturk, Hatice; Kantarci, Alpdogan; Ghattas, Mazen; Dangaria, Smit J; Abdallah, Rima; Morgan, Elise F; Diekwisch, Thomas G H; Ashman, Arthur; Van Dyke, Thomas

    2014-09-01

    This report is the second part of the previously published study on the impact of light/chemical hardening technology and a newly formulated composite graft material for crestal augmentation during immediate implant placement. A total of 48 implants were placed into the sockets of the mesial roots of freshly extracted mandibular premolar teeth in three minipigs. Crestal areas and intrabony spaces were randomly augmented with light-hardened graft materials including a composite graft consisting of polymethylmethacrylate, polyhydroxylethylmethacrylate, and calcium hydroxide (PPCH) plus polyanhydride (PA); PPCH graft; and PA graft, or left untreated. Distal sockets not receiving implants and the sockets of first molars (n = 60) were randomly treated with one of the graft materials or left empty. In addition, two molar sockets were treated with the original PPCH graft material. Quantitative microcomputed tomography (micro-CT) was used to assess alveolar bone structure and tissue compositions. Histologic evaluations included descriptive histology to assess the peri-implant wound healing, as well as histomorphometric measurements to determine bone-to-implant contact (BIC). Both trabecular and cortical bone measurements by micro-CT did not reveal any significant differences among the groups. Sites augmented with PPCH+PA resulted in significantly greater BIC surface than PPCH alone and no-graft-treated implants (P sockets with an intact crestal cortical bone. Histologic evaluations supported the previous findings on implant stability and function and confirmed that PPCH+PA provides a greater BIC with a well-organized implant-bone interface and is useful in crestal augmentation during immediate implant placement.

  14. The Use of Light/Chemically Hardened Polymethylmethacrylate, Polyhydroxylethylmethacrylate, and Calcium Hydroxide Graft Material in Combination With Polyanhydride Around Implants and Extraction Sockets in Minipigs: Part II: Histologic and Micro-CT Evaluations

    Science.gov (United States)

    Hasturk, Hatice; Kantarci, Alpdogan; Ghattas, Mazen; Dangaria, Smit J.; Abdallah, Rima; Morgan, Elise F.; Diekwisch, Thomas G.H.; Ashman, Arthur; Van Dyke, Thomas

    2015-01-01

    Background This report is the second part of the previously published study on the impact of light/chemical hardening technology and a newly formulated composite graft material for crestal augmentation during immediate implant placement. Methods A total of 48 implants were placed into the sockets of the mesial roots of freshly extracted mandibular premolar teeth in three minipigs. Crestal areas and intrabony spaces were randomly augmented with light-hardened graft materials including a composite graft consisting of polymethylmethacrylate, polyhydroxylethylmethacrylate, and calcium hydroxide (PPCH) plus polyanhydride (PA); PPCH graft; and PA graft, or left untreated. Distal sockets not receiving implants and the sockets of first molars (n = 60) were randomly treated with one of the graft materials or left empty. In addition, two molar sockets were treated with the original PPCH graft material. Quantitative microcomputed tomography (micro-CT) was used to assess alveolar bone structure and tissue compositions. Histologic evaluations included descriptive histology to assess the peri-implant wound healing, as well as histomorphometric measurements to determine bone-to-implant contact (BIC). Results Both trabecular and cortical bone measurements by micro-CT did not reveal any significant differences among the groups. Sites augmented with PPCH+PA resulted in significantly greater BIC surface than PPCH alone and no-graft-treated implants (P implant surface in the PPCH+PA group, whereas sites without augmentation showed large gaps between bone and implant surfaces, indicating a slower bone apposition and less BIC surface compared to all other groups. Similar to implant sections, all materials showed positive outcome on trabecular and cortical bone formation in extraction sockets with an intact crestal cortical bone. Conclusion Histologic evaluations supported the previous findings on implant stability and function and confirmed that PPCH+PA provides a greater BIC with a

  15. Interesting images: Multiple coronary artery aneurysms.

    Science.gov (United States)

    Howard, Jonathon M; Viswanath, Omar; Armas, Alfredo; Santana, Orlando; Rosen, Gerald P

    2017-01-01

    We present the case of a 65-year-old male who presented with stable angina and dyspnea on exertion. His initial workup yielded a positive treadmill stress test for reversible apical ischemia, and transthoracic echocardiogram demonstrated impaired systolic function. Cardiac catheterization was then performed, revealing severe atherosclerotic disease including multiple coronary artery aneurysms. As a result, the patient was advised to and subsequently underwent a coronary artery bypass graft. This case highlights the presence of multiple coronary artery aneurysms and the ability to appreciate these pathologic findings on multiple imaging modalities, including coronary angiogram, transesophageal echocardiography, and direct visualization through the surgical field.

  16. Morphological and clinical risk factors for posterior communicating artery aneurysm rupture.

    Science.gov (United States)

    Matsukawa, Hidetoshi; Fujii, Motoharu; Akaike, Gensuke; Uemura, Akihiro; Takahashi, Osamu; Niimi, Yasunari; Shinoda, Masaki

    2014-01-01

    Recent studies have shown that posterior circulation aneurysms, specifically posterior communicating artery (PCoA) aneurysms, are more likely to rupture than other aneurysms. To date, few studies have investigated the factors contributing to PCoA aneurysm rupture. The authors aimed to identify morphological and clinical characteristics predisposing to PCoA aneurysm rupture. The authors retrospectively reviewed 134 consecutive patients with PCoA aneurysms managed at their facility between July 2003 and December 2012. The authors divided patients into groups of those with aneurysmal rupture (n = 39) and without aneurysmal rupture (n = 95) and compared morphological and clinical characteristics. Morphological characteristics were mainly evaluated by 3D CT angiography and included diameter of arteries (anterior cerebral artery, middle cerebral artery, and internal carotid artery), size of the aneurysm, dome-to-neck ratio, neck direction of the aneurysmal dome around the PCoA (medial, lateral, superior, inferior, and posterior), aneurysm bleb formation, whether the PCoA was fetal type, and the existence of other intracranial unruptured aneurysm(s). Patients with ruptured PCoA aneurysms were significantly younger (a higher proportion were PCoA aneurysms showed a lateral direction of the aneurysmal dome around the PCoA, had bleb formation, and the aneurysm was > 7 mm in diameter and/or the dome-to-neck ratio was > 2.0. Multivariate logistic regression analysis showed age PCoA (OR 6.7, p = 0.0001), and bleb formation (OR 11, p PCoA aneurysm rupture. The present results demonstrated that lateral projection of a PCoA aneurysm may be related to rupture.

  17. A composed graft for subclavian artery reconstruction in case of redo surgery for aortic coarctation

    Directory of Open Access Journals (Sweden)

    Fabrizio Sansone

    2013-01-01

    Full Text Available We report the case of a 66-year-old woman admitted to the intensive care unit (ICU for ongoing dyspnea and hemoptoe. She was operated upon in 1979 for aortic coarctation by the interposition of a 14 mm Dacron prosthesis from the left subclavian artery to descending aorta. Clinical evaluation performed over the years was normal with no signs of cardiac failure or prosthesis malfunctioning. The computed tomography scans (CT showed a progressive increase of the descending aorta diameters and the onset of a pseudo-aneurysm of 50 mm in diameter. Patient was re-operated through a median sternotomy enlarged by a left thoracotomy and intra-operative findings revealed the pseudo-aneurysm originating from a dehiscence of the proximal suture. In order to allow a safe reconstruction of the dilated subclavian artery, a T-shaped composed graft was confectioned and then sutured to the descending aorta and the subclavian artery, respectively. Post-operative course was uneventful and three months CT scan showed a normal position of the composed graft.

  18. Spontaneous rupture of a left gastroepiploic artery aneurysm.

    Directory of Open Access Journals (Sweden)

    Rohatgi A

    2002-10-01

    Full Text Available Gastroepiploic aneurysms are extremely rare. They occur mainly in elderly men and in 90% of cases are ruptured at presentation. Visceral aneurysms though rare should be borne in mind in cases of unexplained haemorrhagic shock. We present a case of a 79-year-old man who presented with abdominal pain, hypotension and anaemia but no obvious source of bleeding. He had undergone a prior aorto-bifemoral graft. The patient refused an operation and died the following day.

  19. de novo'' aneurysms following endovascular procedures

    International Nuclear Information System (INIS)

    Briganti, F.; Cirillo, S.; Caranci, F.; Esposito, F.; Maiuri, F.

    2002-01-01

    Two personal cases of ''de novo'' aneurysms of the anterior communicating artery (ACoA) occurring 9 and 4 years, respectively, after endovascular carotid occlusion are described. A review of the 30 reported cases (including our own two) of ''de novo'' aneurysms after occlusion of the major cerebral vessels has shown some features, including a rather long time interval after the endovascular procedure of up to 20-25 years (average 9.6 years), a preferential ACoA (36.3%) and internal carotid artery-posterior communicating artery (ICA-PCoA) (33.3%) location of the ''de novo'' aneurysms, and a 10% rate of multiple aneurysms. These data are compared with those of the group of reported spontaneous ''de novo'' aneurysms after SAH or previous aneurysm clipping. We agree that the frequency of ''de novo'' aneurysms after major-vessel occlusion (two among ten procedures in our series, or 20%) is higher than commonly reported (0 to 11%). For this reason, we suggest that patients who have been submitted to endovascular major-vessel occlusion be followed up for up to 20-25 years after the procedure, using non-invasive imaging studies such as MR angiography and high-resolution CT angiography. On the other hand, periodic digital angiography has a questionable risk-benefit ratio; it may be used when a ''de novo'' aneurysm is detected or suspected on non-invasive studies. The progressive enlargement of the ACoA after carotid occlusion, as described in our case 1, must be considered a radiological finding of risk for ''de novo'' aneurysm formation. (orig.)

  20. Asymptomatic giant coronary aneurysm in an adolescent with Behcet's syndrome

    Directory of Open Access Journals (Sweden)

    Kahn Philip J

    2012-01-01

    Full Text Available Abstract Objective Behcet's is an idiopathic multi-organ syndrome, which may have onset during childhood. Vascular involvement is uncommon, with rarely reported coronary aneurysm formation. We present a case report of a teenager girl who developed recalcitrant life-threatening Behcet's vasculitis, involving both small and large venous and arterial systems including a giant coronary aneurysm. Case report De-identified data were collected retrospectively in case report format. Although our sixteen year old female with Behcet's vasculitis had resolution of many arterial aneurysms, she had persistent venous thrombosis of large vessels, as well as persistent, giant arterial aneurysms requiring intra-arterial coiling of a lumbar artery and coronary bypass grafting despite intensive immunosuppression including glucocorticoids, cyclophosphamide, infliximab, methotrexate, azathioprine and intravenous immunoglobulin. Conclusions Vascular manifestations may be seen in Behcet's syndrome, including asymptomatic coronary aneurysm, which may be refractory to immunosuppression and ultimately require surgical intervention. Increased awareness is essential for prompt diagnosis and management.

  1. Technical Considerations of Giant Right Coronary Artery Aneurysm Exclusion

    Directory of Open Access Journals (Sweden)

    James Barr

    2016-01-01

    Full Text Available Giant coronary artery aneurysms are rare clinical entities. We report the case of a 49-year-old man who presented with dyspnoea and exertional chest pain. Investigations confirmed an aneurysmal right coronary artery measuring 4 cm with a fistulous communication to the right atrium. Following right atriotomy, the fistula was oversewn and the aneurysmal right coronary artery ligated at its origin and at several points along its course. A saphenous vein graft was anastomosed to the posterior descending artery. Persistent ventricular fibrillation occurred upon chest closure, attributed to ischaemia following ligation of the aneurysmal coronary artery. Emergent resternotomy and internal defibrillation were successfully performed. The sternum was stented open to reduce right ventricular strain and closed the following day. The patient made an unremarkable recovery. We here address the technical challenges associated with surgical repair of right coronary aneurysms and the physiology and management of potential complications.

  2. Skin graft

    Science.gov (United States)

    Skin transplant; Skin autografting; FTSG; STSG; Split thickness skin graft; Full thickness skin graft ... donor site. Most people who are having a skin graft have a split-thickness skin graft. This takes ...

  3. Suprarenal fixation barbs can induce renal artery occlusion in endovascular aortic aneurysm repair.

    Science.gov (United States)

    Subedi, Shree K; Lee, Andy M; Landis, Gregg S

    2010-01-01

    Renal artery occlusion following endovascular abdominal aortic aneurysm repair with suprarenal fixation is uncommon. We report one patient who was found to develop renal artery occlusion and parenchymal infarction 6 months after repair using an endovascular graft with suprarenal fixation. Our patient underwent emergent endovascular repair of a symptomatic 6 cm abdominal aortic aneurysm. The covered portion of the endograft was inadvertently deployed well below the renal artery orifices. At the completion of the procedure both renal arteries were confirmed to be patent. One month postoperatively, a computed tomographic (CT) scan showed exclusion of the aortic sac and normal enhancement of both kidneys. At 6 months, the patient was found to have elevated serum creatinine levels despite having no clinical symptoms. CT scanning revealed a nonenhancing left kidney, and angiography demonstrated an occlusion of the left renal artery. A barb welded to the bare metal stent appeared to be impinging on the renal artery. We believe that renal artery occlusion after endovascular repair can occur due to repetitive injury to the renal artery orifice from barbs welded to the bare metal stent. To our knowledge, this is the first reported case of renal artery occlusion caused by repetitive injury from transrenal fixation systems. Copyright 2010 Annals of Vascular Surgery Inc. Published by Elsevier Inc. All rights reserved.

  4. Endovascular Treatment of Ruptured Abdominal Aortic Aneurysm with Aortocaval Fistula

    International Nuclear Information System (INIS)

    Guzzardi, Giuseppe; Fossaceca, Rita; Divenuto, Ignazio; Musiani, Antonello; Brustia, Piero; Carriero, Alessandro

    2010-01-01

    Aortocaval fistula (ACF) is a rare complication of abdominal aortic aneurysm (AAA). We report the endovascular repair of an AAA rupture into the inferior vena cava. A 78-year-old woman was admitted to our hospital for acute hypotension. She presented with a pulsatile abdominal mass and became rapidly anuric. Abdominal computed tomography (CT) showed an AAA rupture into the inferior vena cava. The features of the AAA made it suitable for endovascular repair. To prevent pulmonary embolism caused by the presence of sac thrombosis near the vena cava lumen, a temporary vena cava filter was deployed before the procedure. A bifurcated stent-graft was placed with the patient under local anaesthesia, and the AAA was successfully treated. A transient type II endoleak was detected on CT 3 days after endograft placement. At routine follow-up 6 and 12 months after the procedure, the patient was in good clinical condition, and the type II endoleak had sealed completely. Endovascular treatment offers an attractive therapeutic alternative to open repair in case of ACF; however, only small numbers of patients have been treated, and long-term follow-up interval is lacking.

  5. Rerupture of intracranial aneurysms: a clinicoanatomic study

    NARCIS (Netherlands)

    Hijdra, A.; Vermeulen, M.; van Gijn, J.; van Crevel, H.

    1987-01-01

    In a series of 176 prospectively studied patients who survived for at least 24 hours after aneurysmal subarachnoid hemorrhage, 39 had at least one computerized tomography (CT)-proven rebleed within 4 weeks after the first rupture. There were peaks in the incidence of rebleeding at the end of the 2nd

  6. Infolding of fenestrated endovascular stent graft.

    Science.gov (United States)

    Zelt, Jason G E; Jetty, Prasad; Hadziomerovic, Adnan; Nagpal, Sudhir

    2017-09-01

    We report a case of infolding of a fenestrated stent graft involving the visceral vessel segment after a juxtarenal abdominal aorta aneurysm repair. The patient remains free of any significant endoleak, and the aortic sac has shown regression. The patient remains asymptomatic, with no abdominal pain, with normal renal function, and without ischemic limb complications. We hypothesize that significant graft oversizing (20%-30%) with asymmetric engineering of the diameter-reducing ties may have contributed to the infolding. Because of the patient's asymptomatic nature and general medical comorbidities, further intervention was deemed inappropriate as the aneurysmal sac is regressing despite the infolding.

  7. Soft tissue aneurysmal bone cyst

    Energy Technology Data Exchange (ETDEWEB)

    Wang, X.L.; Gielen, J.L.; Delrue, F.; De Schepper, A.M.A. [Department of Radiology, Universitair Ziekenhuis Antwerpen (University of Antwerp), Wilrijkstraat 10, 2650, Edegem (Belgium); Salgado, R. [Department of Pathology, Universitair Ziekenhuis Antwerpen (University of Antwerp), Wilrijkstraat 10, 2650, Edegem (Belgium)

    2004-08-01

    A soft tissue aneurysmal bone cyst located in the right gluteus medius of a 21-year-old man is reported. On conventional radiography, the lesion demonstrated a spherically trabeculated mass with a calcific rim. On CT scan, it showed a well-organized peripheral calcification resembling a myositis ossificans. On MRI, it presented as a multilocular, cystic lesion with fluid-fluid levels. The lesion had no solid components except for intralesional septa. Although findings on imaging and histology were identical to those described in classical aneurysmal bone cyst, diagnosis was delayed because of lack of knowledge of this entity and its resemblance to the more familiar post-traumatic heterotopic ossification (myositis ossificans). (orig.)

  8. Soft tissue aneurysmal bone cyst

    International Nuclear Information System (INIS)

    Wang, X.L.; Gielen, J.L.; Delrue, F.; De Schepper, A.M.A.; Salgado, R.

    2004-01-01

    A soft tissue aneurysmal bone cyst located in the right gluteus medius of a 21-year-old man is reported. On conventional radiography, the lesion demonstrated a spherically trabeculated mass with a calcific rim. On CT scan, it showed a well-organized peripheral calcification resembling a myositis ossificans. On MRI, it presented as a multilocular, cystic lesion with fluid-fluid levels. The lesion had no solid components except for intralesional septa. Although findings on imaging and histology were identical to those described in classical aneurysmal bone cyst, diagnosis was delayed because of lack of knowledge of this entity and its resemblance to the more familiar post-traumatic heterotopic ossification (myositis ossificans). (orig.)

  9. Transcatheter Embolization of a Renal Artery Aneurysm Using Ethylene Vinyl Alcohol Copolymer

    International Nuclear Information System (INIS)

    Rautio, Riitta; Haapanen, Arto

    2007-01-01

    Our aim was to treat a clinically silent renal artery aneurysm. The patient was a 76-year-old man with elevated prostate-specific antigen and prostata biopsies with a gradus II-III adenocarcinoma who was incidentally found to have an aneurysm in his right renal artery. We performed a successful transcatheter embolization of the aneurysm using ethylene vinyl alcohol copolymer (Onyx). To avoid migration of the liquid material into the parent artery, a balloon was inflated in the orifice of the neck of the aneurysm while the liquid was injected. Five-month follow-up computed tomography (CT) imaging confirmed total occlusion of the aneurysm

  10. Aneurysmal bone cyst of the mandible managed by conservative surgical therapy with preoperative embolization

    Energy Technology Data Exchange (ETDEWEB)

    An, Seo Young [School of Dentistry, Kyungpook National University, Daegu (Korea, Republic of)

    2012-03-15

    A 9-year-old girl visited our hospital, complaining of a rapid-growing and rigid swelling on the left posterior mandibular area. Panoramic radiograph showed a moderately defined multilocular honeycomb appearance involving the left mandibular body. CT scan revealed an expansile, multilocular osteolytic lesion and multiple fluid levels within cystic spaces. Bone scan demonstrated increased radiotracer uptake and angiography showed a highly vascularized lesion. The lesion was suspected as aneurysmal bone cyst (ABC) and preoperative embolization was performed, which minimize the extent of operation and the surgical complication. The lesion was treated by surgical curettage and lateral decortication with repositioning. No additional treatment such as a surgical reconstruction or bone graft was needed. Early diagnosis of ABC is very important and appropriate treatment should be performed considering several factors such as age, surgical complication, and possibility of recurrence.

  11. Ruptured submitral aneurysm

    Directory of Open Access Journals (Sweden)

    V. Shukla

    2016-09-01

    Full Text Available Submitral aneurysm is a rare entity, with around few hundred cases reported till date. Presentation can be varied. We describe here a case of submitral aneurysm in a young male with rupture into the left atrium cavity.

  12. Abdominal Aortic Aneurysm (AAA)

    Science.gov (United States)

    ... Professions Site Index A-Z Abdominal Aortic Aneurysm (AAA) Abdominal aortic aneurysm (AAA) occurs when atherosclerosis or plaque buildup causes the ... weak and bulge outward like a balloon. An AAA develops slowly over time and has few noticeable ...

  13. Role of graft oversizing in the fixation strength of barbed endovascular grafts.

    Science.gov (United States)

    Kratzberg, Jarin A; Golzarian, Jafar; Raghavan, Madhavan L

    2009-06-01

    The role of endovascular graft oversizing on risk of distal graft migration following endovascular aneurysm repair for abdominal aortic aneurysm is poorly understood. A controlled in vitro investigation of the role of oversizing in graft-aorta attachment strength for endovascular grafts (EVGs) with barbs was performed. Barbed stent grafts (N = 20) with controlled graft oversizing varying from 4-45% were fabricated while maintaining other design variables unchanged. A flow loop with physiological flow characteristics and a biosynthetic aortic aneurysm phantom (synthetic aneurysm model with a bovine aortic neck) were developed. The stent grafts were deployed into the aortic neck of the bio-synthetic aortic aneurysm phantom under realistic flow conditions. Computed tomography imaging of the graft-aorta complex was used to document attachment characteristics such as graft apposition, number of barbs penetrated, and penetration depth and angle. The strength of graft attachment to the aortic neck was assessed using mechanical pullout testing. Stent grafts were categorized into four groups based on oversizing: 4-10%; 11-20%; 21-30%; and greater than 30% oversizing. Pullout force, a measure of post-deployment fixation strength was not different between 4-10% (6.23 +/- 1.90 N), 11-20% (6.25 +/- 1.84 N) and 20-30% (5.85 +/- 1.89 N) groups, but significantly lower for the group with greater than 30% oversizing (3.67 +/- 1.41 N). Increasing oversizing caused a proportional decrease in the number of barbs penetrating the aortic wall (correlation = -0.83). Of the 14 barbs available in the stent graft, 89% of the barbs (12.5 of 14 on average) penetrated the aortic wall in the 4-10% oversizing group while only 38% (5.25 of 14) did for the greater than 30% group (P barb penetration were found to be positively correlated to pullout force. Greater than 30% graft oversizing affects both barb penetration and graft apposition adversely resulting in a low pullout force in this in vitro

  14. Brain Aneurysm: Treatment Options

    Science.gov (United States)

    ... inoperable aneurysms. Decisions regarding management of an unruptured brain aneurysm are based on the careful comparison of the short- and ... so Tired? How Do I Deal With Depression? Learning Principles to Aid Recovery The Memory Book ... Aneurysm Foundation Support Community Research & Grants BAF Research ...

  15. Salvage of bilateral renal artery occlusion after endovascular aneurysm repair with open splenorenal bypass

    Directory of Open Access Journals (Sweden)

    Samuel Jessula, MDCM

    2017-09-01

    Full Text Available We report renal salvage maneuvers after accidental bilateral renal artery coverage during endovascular aneurysm repair of an infrarenal abdominal aortic aneurysm. A 79-year-old man with an infrarenal abdominal aortic aneurysm was treated with endovascular aneurysm repair. Completion angiography demonstrated coverage of the renal arteries. Several revascularization techniques were attempted, including endograft repositioning and endovascular stenting through the femoral and brachial approach. The patient eventually underwent open splenorenal bypass with a Y Gore-Tex graft (W. L. Gore & Associates, Flagstaff, Ariz. After 3 months, computed tomography showed no evidence of endoleak and patent renal arteries. Renal function was well maintained, and the patient did not require dialysis.

  16. Mesenteric ischaemia after endovascular coiling of ruptured cerebral aneurysms.

    LENUS (Irish Health Repository)

    Kamel, M H

    2012-02-03

    Three patients were referred to a national neurosurgical centre following CT evidence of subarachnoid haemorrhage. The three patients, who were referred from different institutions within a seven week period, were Fisher grade 3 and WFNS Grade I at all times. Angiography showed a PCOM aneurysm in one case, a ruptured Basilar tip aneurysm and an unruptured ACOM aneurysm in another case, and an ACOM aneurysm in the third case. It was decided that the aneurysms were suitable for endovascular coiling. These patients had unremarkable intraoperative catheterizations and coiling but subsequently deteriorated post-operatively due to mesenteric ischaemia. Two patients required colectomy for mesenteric ischaemia, and the third arrested secondary to sepsis from bowel perforation. We discuss the various causes that may explain this association, and we alert the neurosurgical community for this complication which has not been reported before.

  17. Coronary artery aneurysms

    Energy Technology Data Exchange (ETDEWEB)

    Koischwitz, D.; Harder, T.; Schuppan, U.; Thurn, P.

    1982-04-01

    Seven saccular coronary artery aneurysms have been demonstrated in the course of 1452 selective coronary artery angiograms. In six patients they were arterio-sclerotic; in one patient the aneurysm must have been congenital or of mycotic-embolic origin. The differential diagnosis between true aneurysms and other causes of vascular dilatation is discussed. Coronary artery aneurysms have a poor prognosis because of the possibility of rupture with resultant cardiac tamponade, or the development of thrombo-embolic myocardial infarction. These aneurysms can only be diagnosed by means of coronary angiography and require appropriate treatment.

  18. Two-dimensional versus three-dimensional CT angiography in analysis of anatomical suitability for stentgraft repair of abdominal aortic aneurysms

    International Nuclear Information System (INIS)

    Pitoulias, Georgios A.; Aslanidou, Eleni A.; Papadimitriou, Dimitrios K.; Donas, Konstantinos P.; Schulte, Stefan

    2011-01-01

    Background The morphological analysis prior to endovascular abdominal aneurysm repair (EVAR) plays an important role in long-term outcomes. Post-imaging analysis of computed tomographic angiography (CTA) by three-dimensional reconstruction with central lumen line detection (CLL 3D-CTA) enables measurements to be made in orthogonal slices. This might be more precise than equal post-imaging analysis in axial slices by two-dimensional computed tomographic angiography (2D-CTA). Purpose To evaluate the intra- and interobserver variability of CLL 3D-CTA and 2D-CTA post-imaging analysis methods and the agreement between them in pre-EVAR suitability analysis of patients with abdominal aortic aneurysm (AAA). Material and Methods Anonymized CTA data-sets from 70 patients with AAA were analyzed retrospectively. Length measurements included proximal and distal aortic neck lengths and total distance from the lower renal artery to the higher iliac bifurcation. Width measurements included proximal and distal neck diameters, maximum AAA diameter and common iliac diameters just above the iliac bifurcations. The measurements were performed in random order by two vascular surgeons, twice per method with 1-month interval between readings. In the CLL 3D-CTA method we used semi-automated CLL detection by software and manual measurements on CTA slices perpendicular to CLL. The equal measurements in 2D-CTA were performed manually on axial CTA slices using a DICOM viewer workstation. The intra- and interobserver variability, as well as the agreement between the two methods were assessed by Bland-Altman test and bivariate correlation analysis. Results The intraobserver variability was significantly higher in 2D-CTA measurements for both readers. The interobserver variability was significant in 2D-CTA measurements of proximal neck dimensions while the agreement in CLL 3D-CTA analysis between the two readers was excellent in all studied parameters. The agreement between the two suitability

  19. Delayed Rebleeding of Cerebral Aneurysm Misdiagnosed as Traumatic Subarachnoid Hemorrhage

    OpenAIRE

    Song, Seung-Yoon; Kim, Dae-Won; Park, Jong-Tae; Kang, Sung-Don

    2016-01-01

    An intracranial saccular aneurysm is uncommonly diagnosed in a patient with closed head trauma. We herein present a patient with delayed rebleeding of a cerebral aneurysm misdiagnosed as traumatic subarachnoid hemorrhage (SAH). A 26-year-old female visited our emergency department because of headache after a motorcycle accident. Brain computed tomography (CT) showed a right-side dominant SAH in Sylvian fissure. Although traumatic SAH was strongly suggested because of the history of head traum...

  20. Common hepatic artery aneurysm: Pseudopseudocyst of the pancreas

    International Nuclear Information System (INIS)

    Shultz, S.; Druy, E.M.; Friedman, A.C.

    1985-01-01

    The preoperative diagnosis of hepatic artery aneurysm is uncommon, and its presentation as a pancreatic mass is rare. Because of its great potential for rupture early diagnosis and treatment is essential. The authors report two cases of aneurysms of the common hepatic artery, which on CT presented as a cystic mass in the head of the pancreas. These cases illustrate the importance of using 10-mm serial sections through the pancreas after a bolus injection of intravenous contrast material in order to allow distinction between hepatic artery aneurysm and other, more common, cystic masses of the pancreas

  1. Myocardial ischemia due to compression of an unruptured thoracic aortic aneurysm in a patient with Marfan syndrome.

    Science.gov (United States)

    Minami, Hiroya; Asada, Tatsuro; Gan, Kunio; Abe, Koichiro; Izumi, Satoshi

    2007-06-01

    We report a 33-year-old woman who had a 60-mm thoracic aneurysm of the ascending aorta with Marfan syndrome and effort angina due to compression of the right coronary artery (RCA) by the aneurysm. Surgery was performed using the Bentall procedure and a coronary artery bypass graft to the RCA. Postoperatively, coronary angiography showed that the coronary flow of the RCA was restored by removing the aneurysmal compression. The patient was discharged without angina on postoperative day 21.

  2. An Abdominal Aortic Aneurysm, Intramural Thrombus and Moderate Leak in an Asian Man Presenting with Acute Gastroenteritis

    Directory of Open Access Journals (Sweden)

    Abdalla Khalil

    2017-11-01

    Full Text Available Introduction: Missing a leaking abdominal aortic aneurysm (AAA is common in medical practice because few at-risk patients have a history of AAA and many have an unusual presentation. Background: AAA is less common among Asians than white Caucasians of the same age. Our patient had no significant risk factors apart from age and sex and had an unusual presentation. Patient and Methods: A 67-year-old Asian man presented to the emergency room (ER with a 1-day history of nausea, vomiting, diarrhoea, fever and abdominal pain. He was febrile, dehydrated. and had marked tenderness at the right iliac fossa. Laboratory findings suggested bacterial gastroenteritis but this did not explain the localized tenderness at the right iliac fossa. Result and Discussion: A CT scan of the abdomen revealed an AAA arising above the origins of the renal arteries, an intramural thrombus, a retroperitoneal haematoma and a leak extending to the right iliac fossa. The patient was transferred to another hospital and underwent exploratory laparotomy, surgical repair of the aneurysm, and aortobi-iliac grafting with removal of the thrombus. The patient was discharged in good shape 3 weeks after surgery. Without the CT scan of the abdomen, the AAA could have been missed and the patient treated for severe gastroenteritis.

  3. Primary congenital abdominal aortic aneurysm: a case report with perinatal serial follow-up imaging

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Jung Im; Lee, Whal; Chung, Jin Wook; Park, Jae Hyung [Seoul National University College of Medicine, Seoul National University Hospital, Department of Radiology, Seoul (Korea); Kim, Sang Joon [Seoul National University College of Medicine, Seoul National University Hospital, Department of Surgery, Seoul (Korea); Seo, Jeong-Wook [Seoul National University College of Medicine, Seoul National University Hospital, Department of Pathology, Seoul (Korea)

    2008-11-15

    Abdominal aortic aneurysms in neonates and infants are rare and are usually associated with infection, vasculitis, connective tissue disorder, or iatrogenic trauma such as umbilical catheterization. An idiopathic congenital abdominal aortic aneurysm is the least common category and there are few descriptions of the imaging features. We present the antenatal and postnatal imaging findings of an idiopathic congenital abdominal aortic aneurysm including the findings on US, MRI and CT. (orig.)

  4. A mycotic pulmonary artery aneurysm associated with candida endocarditis: Case report

    Energy Technology Data Exchange (ETDEWEB)

    Moon, Jin Il; Lee, Ji Won; Jeong, Yeon Joo; Song, Seung Hwan [Pusan National University School of Medicine, Medical Research Institute, Pusan National University Hospital, Busan (Korea, Republic of)

    2014-03-15

    We report a case of a mycotic pulmonary aneurysm associated with Candida endocarditis in a 53-year-old male with lymphoma. The initial diagnosis was a pulmonary artery aneurysm attributable to vasculitis, such as that associated with Behcet's disease, but a mycotic pulmonary artery aneurysm was later considered as a differential diagnosis. Identification of valve vegetation on the chest CT was helpful in this regard. We review the literature on the disease etiology, radiological findings, and management options.

  5. A mycotic pulmonary artery aneurysm associated with candida endocarditis: Case report

    International Nuclear Information System (INIS)

    Moon, Jin Il; Lee, Ji Won; Jeong, Yeon Joo; Song, Seung Hwan

    2014-01-01

    We report a case of a mycotic pulmonary aneurysm associated with Candida endocarditis in a 53-year-old male with lymphoma. The initial diagnosis was a pulmonary artery aneurysm attributable to vasculitis, such as that associated with Behcet's disease, but a mycotic pulmonary artery aneurysm was later considered as a differential diagnosis. Identification of valve vegetation on the chest CT was helpful in this regard. We review the literature on the disease etiology, radiological findings, and management options.

  6. Diagnosis and treatment of traumatic intracranial aneurysm in childhood

    International Nuclear Information System (INIS)

    Yu Juming; Fan Guoping; Zhong Weixing; Zhang Yongping; Peng Haiteng; Zhu Ming; Cheng Yongde

    2008-01-01

    Objective: To evaluate the diagnosis, safety and efficacy of interventional therapy and surgery for child traumatic intracranial aneurysms. Methods: Five patients with traumatic intracranial aneurysms including three males and two females, age ranged from 2 to 10 years old; 5 had undertaken CT and MR scanings. All of them showed traumatic subarachnoid hemorrhage in 2, intracerebral hematoma in the right occipital and the left temporal respectively in 2 and another one with somewhat bleeding at the posterior fossa and right trigone of lateral ventricles and subdural bleeding at the tentorium edge. The detailed vascular involvement diagnosis were made by DSA revealing one of left C1 segmental internal carotid artery traumatic aneurysm, one of the branch of right sylvian artery traumatic aneurysm, one of left middle cerebral artery traumatic aneurysm, one of left posterior cerebral artery traumatic aneurysm, one of the branch of right posterior inferior cerebellar artery traumatic aneurysm. Two of them were treated by embolization therapy with CDC and two by surgery. Results: The CDC embolization in 2 cases and the surgical operation for another 2 were all succeeded without death or complications. The last case was followed up closely. Conclusions: Traumatic intracranial aneurysm is rare in childhood but endovascular treatment with CDC and surgery is efficient and safe, yet the long-term efficacy is still relied on follow-up. (authors)

  7. The effects of bone erosion from aortic aneurysm on the regional uptake of FDG

    DEFF Research Database (Denmark)

    Louring-Andersen, J.; Law, I.

    2008-01-01

    aorta just below the carina. An abnormal crescent-shaped uptake was identified at the margin between the aneurysm and the adjacent thoracic vertebral bodies. At this site a correspondingly shaped bone erosion on CT was proof of the chronic effects of the aneurysm. There were no signs of regional......A 71-year-old white man with a known right-sided apical nonsmall cell lung carcinoma was referred for a F-18 FDG whole body PET-CT examination after chemotherapy before radiotherapy. A staging CT scan had revealed an asymptomatic fusiform 65 mm in diameter nondissecting aneurysm of the thoracic...

  8. Brain Aneurysm Statistics and Facts

    Science.gov (United States)

    ... Statistics and Facts A- A A+ Brain Aneurysm Statistics and Facts An estimated 6 million people in ... Understanding the Brain Warning Signs/ Symptoms Brain Aneurysm Statistics and Facts Seeking Medical Attention Risk Factors Aneurysm ...

  9. Endovascular aneurysm repair (EVAR) follow-up imaging: the assessment and treatment of common postoperative complications

    International Nuclear Information System (INIS)

    Ilyas, S.; Shaida, N.; Thakor, A.S.; Winterbottom, A.; Cousins, C.

    2015-01-01

    Endovascular abdominal aortic aneurysm repair (EVAR) is a well-established procedure, which has long-term mortality rates similar to that of open repair. It has the additional benefit of being less invasive, making it the favoured method of treating abdominal aortic aneurysms in elderly and high-risk patients with multiple co-morbidities. The main disadvantage of EVAR is the higher rate of re-intervention, due to device-related complications, including endoleaks, limb occlusion, stent migration, kinking, and infection. As a result lifelong surveillance is required. In order to avoid missing these complications, intricate knowledge of stent graft design, good-quality diagnostic ultrasound skills, multiplanar reformatting of CT images, and reproducible investigations are important. Most of these complications can be treated via an endovascular approach using cuff extensions, uncovered stents, coils, and liquid embolic agents. Open surgery is reserved for complex complications, where an endovascular approach is not feasible. - Highlights: • Comprehensive pictorial review of EVAR related complications. • Importance of life-long EVAR surveillance, to prevent aortic rupture or lower limb ischaemia. • Identification and management of endoleaks, rupture, migration, kink/infolding, occlusion and infection

  10. Giant partially thrombosed 4 th ventricular posterior inferior cerebellar artery aneurysm; microsurgical management

    Directory of Open Access Journals (Sweden)

    Forhad Hossain Chowdhury

    2014-01-01

    Full Text Available A 42-year-old woman presented with a 3-month history of progressive occipital headache, vomiting, walking difficulty, and repeated fall. She had no history of sudden and severe headache. She had positive cerebellar signs, predominantly on the right side. Computerized tomography (CT scan, CT angiogram, and magnetic resonance image (MRI of the brain showed suspected partially thrombosed giant 4 th ventricular posterior inferior cerebellar artery aneurysm. Patient developed severe hypersensitivity reaction during both CT scan and MRI after contrast injection. Though needed, digital subtraction angiogram (DSA of cerebral vessels was not done. The aneurysm was managed by microsurgical clipping of the aneurysm neck and partial excision of thrombosed aneurysm. Here, we report the details of management of these difficult giant aneurysm without DSA.

  11. Endovascular Management of Ruptured Pancreaticoduodenal Artery Aneurysms Associated with Celiac Axis Stenosis

    International Nuclear Information System (INIS)

    Suzuki, Kojiro; Tachi, Yasushi; Ito, Shinji; Maruyama, Kunihiro; Mori, Yoshine; Komada, Tomohiro; Matsushima, Masaya; Ota, Toyohiro; Naganawa, Shinji

    2008-01-01

    The purpose of this study was to assess the efficacy of transcatheter arterial embolization for ruptured pancreaticoduodenal artery (PDA) aneurysms associated with celiac axis stenosis (CS). Seven patients (four men and three women; mean age, 64; range, 43-84) were treated with transcatheter arterial embolization between 2002 and 2007. They were analyzed with regard to the clinical presentation, radiological finding, procedure, and outcome. All patients presented with sudden epigastric pain or abdominal discomfort. Contrast-enhanced CT showed a small aneurysm and retroperitoneal hematoma around the pancreatic head in all patients. The aneurysms ranged from 0.3 to 0.9 cm in size. In one patient, two aneurysms were detected. The aneurysms were located in the pancreaticoduodenal artery (n = 5) and the dorsal pancreatic artery (n = 3). Embolization was performed with microcoils in all aneurysms (n = 8). N-Butyl 2-cyanoacrylate (n = 1) and gelatine particle (n = 1) were also used. Complete occlusion was achieved in four patients. In the other three patients, a significantly reduced flow to the aneurysm remained at final angiography. However, these aneurysms were thrombosed on follow-up CT within 2 weeks. And there was no recurrence of the symptoms and bleeding during follow-up (mean, 28 months; range, 5-65 months) in all patients. In conclusion, transcatheter arterial embolization for PDA aneurysms associated with CS is effective. Significant reduction of the flow to the aneurysm at final angiography may be predictive of future thrombosis.

  12. Endovascular Aortic Aneurysm Repair for Abdominal Aortic Aneurysm: Single Center Experience in 122 Patients

    International Nuclear Information System (INIS)

    Lee, Yun Young; Song, Jang Hyeon; Kim, Yong Tae; Yim, Nam Yeol; Kim, Jae Kyu; Lee, Ho Kyun; Choi, Soo Jin Na; Chung, Sang Young; Kim, Soo Hyun; Chang, Nam Kyu

    2013-01-01

    To analyze a single center experience of endovascular aneurysm repair (EVAR) for abdominal aortic aneurysms. Results of 122 patients who underwent EVAR were analyzed, retrospectively. Sex, age, aneurysmal morphology, hostile neck anatomy, preprocedural and postprocedural sac-diameter, technical and clinical success, postprocedural complication and need of additional procedure were analyzed. A total of 111 male and 11 female patients were included. Morphology of the aneurysms was as follows: fusiform (n = 108), saccular (n = 3) and ruptured type (n = 11). Sixty-four patients had hostile neck anatomy. The preprocedural mean sac-diameter was 52.4 mm. Postprocedural sac-diameter was decreased or stable in 110 patients (90.2%) and increased in 8 patients (6.6%). Technical success rate was 100% and clinical success rate was 86.1%. Fifty-one patients showed endoleak (41.8%) and 15 patients (12.3%) underwent secondary intervention due to type I endoleak (n = 4), type II endoleak (n = 4) and stent-graft thrombosis (n = 7). EVAR is a safe and effective therapy for abdominal aortic aneurysm, and it has high technical success and clinical success rate, and low complication rate.

  13. The mechanism of cerebral aneurysmal formation

    International Nuclear Information System (INIS)

    Yokoi, Toshihiro; Nozaki, Kazuhiko

    2010-01-01

    Cerebral aneurysm is a disease of poor prognosis and MR- and CT-angiographies are used for its diagnosis and in the preventive therapy of its rupture. Here discussed are formation and growth leading to rupture of the lesion for its advanced diagnosis and prevention of rupturing. Beginning from findings in animal experimentation in mice, rats and monkeys, discussed are pathology of the aneurysm, genes related with its formation, molecular biological approaches concerning apoptosis and NF-kB/TNF-α related inflammatory reactions, participation of sex hormone, clinical hemodynamic analyses based on 3D data from CT and MRI findings, and clinical studies. Authors consider that local hemodynamic stress loading is possibly related to cerebral aneurysm formation as it is yielded at the loading part of the vessel in human and in animal models. The aneurysm is possibly a result of remodeling disturbance by the load and subsequent excessive involution of the artery. In the process, probably included are the inflammation, apoptosis, degradation of extracellular matrix and functional impairment of endotherial cells. Future elucidation of molecular mechanisms underlying the aneurismal growth and rupture will bring about the improved treatment to prevent the disease by stabilizing the aneurismal wall. (T.T.)

  14. Hepatic artery aneurysms (HAAs)

    International Nuclear Information System (INIS)

    Nosratini, H.

    2004-01-01

    The hepatic artery aneurysms are rare, especially in interahepatic branches, The frequency consists of 75-80% extrahepatic and 20-25% intrahepatic. Catheterization is achieved usually from common femoral artery, other methods implemented in the case of unsuccessful catheterization from femoral artery, are translumbar and brachial catheterization. The study consist of 565 patients that were referred to the angiography ward, During seven years of assessment, five cases of hepatic artery aneurysm were found; this is a rare condition reported in the English literature. In the literature as well as in this case report the hepatic artery aneurysms are rare. In reported series the extrahepatic artery aneurysms are found more often than in the intrahepatic artery aneurysm but in this case report intrahepatic artery aneurysms are more than extrahepatic one. (author)

  15. Aberrant right subclavian artery aneurysm confirmed by computerized tomography. Aneurisma de arteria subclavia derecha aberrante

    Energy Technology Data Exchange (ETDEWEB)

    Arteche, M.D.; Tejera, E.; Vega-Hazas, G.

    1991-01-01

    We present a case of aberrant right subclavian artery aneurysm in an asymptomatic woman. This disorder was found by chance in a thorax radiography due to an upper right mediastinal mass. CT confirmed the vascular anomaly as well as the aneurysm occurrence. (Author)

  16. Wall stress analysis of abdominal aortic aneurysms using 3D ultrasound

    NARCIS (Netherlands)

    Kok, A. M.; Nguyen, V.L.; Speelman, L.; Schurink, G.W.H.; van de Vosse, F.N.; Lopata, R.G.P.

    2014-01-01

    Wall stress analysis of abdominal aortic aneurysms is a novel tool that has proven high potential to improve risk stratification of abdominal aortic aneurysms (AAAs). Wall stress analysis is based on computed tomography (CT) and magnetic resonance imaging, however, 3D ultrasound (US) has not been

  17. Predictive value of ridge dimensions on autologous bone graft resorption in staged maxillary sinus augmentation surgery using Cone-Beam CT.

    NARCIS (Netherlands)

    Klijn, R.J.; Beucken, J.J.J.P van den; Bronkhorst, E.M.; Berge, S.J.; Meijer, G.J.; Jansen, J.B.M.J.

    2012-01-01

    INTRODUCTION: No studies are available that provide predictive parameters regarding the expected amount of resorption after maxillary sinus augmentation surgery using autologous bone grafts. Therefore, the aim of this study was to determine parameters influencing the outcome of the bone graft

  18. A clinical feature and therapeutic strategy in pituitary adenomas associated with intracranial aneurysms

    International Nuclear Information System (INIS)

    Sasagawa, Yasuo; Tachibana, Osamu; Shiraga, Shunsuke; Takata, Hisasi; Akai, Takuya; Iizuka, Hideaki

    2012-01-01

    We studied the clinical feature and treatment strategy of pituitary adenomas associated with intracranial aneurysms. Among 102 pituitary adenoma patients (mean age: 54.8 years old) who received MR angiography and/or 3D-CT angiography,seven patients (6.9%) had intracranial aneurysms. The association of an aneurysm was more common in large size adenomas (p<0.05). According to the location of the aneurysms,five patients had these in the paraclinoid portion or cavernous portion of the internal carotid artery. Using MR images,we classified the aneurysms associated with pituitary adenomas as non-adjacent,adjacent,and intra-adenoma types. In non-adjacent types,an aneurysm is located apart from the adenoma,and has less chance of exposure during transsphenoidal surgery. In adjacent types,an aneurysm is located adjacent to the adenoma,and could be exposed during transsphenoidal surgery. In intra-adenoma types,an aneurysm is encased in the adenoma. In non-adjacent type aneurysms,a resection of the pituitary adenoma can be carried out before aneurysm treatment due to the low risk of rupture during surgery. In adjacent types,a tumor resection can precede aneurysm treatment in cases of low rupture risk aneurysms and untreatable aneurysms. In intra-adenoma types,adenoma resection should come after treatment of the aneurysms. Neurosurgeons should be careful about not only the presence of aneurysms in preoperative images during transsphenoidal surgery planning,but also their locations and proximity to adenomas. Such information may be crucial in deciding the order of treatment. (author)

  19. Effect of Graft Material on Red Blood Cell Loss Following Aortic Surgery

    National Research Council Canada - National Science Library

    Fisher, Jay

    1990-01-01

    ... (Meadox Woven Double Velour) and PTFE (Gore-Tex) grafts. A total of 25 patients (13 Dacron, 12 PTFE) were studied including 21 with abdominal aortic aneurysms, and 4 with aorto-iliac occlusive disease...

  20. Magnetic resonance imaging of aneurysmal subarachnoid hemorrhage

    International Nuclear Information System (INIS)

    Ogawa, Toshihide; Shimosegawa, Eku; Inugami, Atsushi; Shishido, Fumio; Fujita, Hideaki; Ito, Hiroshi; Uemura, Kazuo; Yasui, Nobuyuki

    1991-01-01

    Magnetic resonance imaging of subarachnoid hemorrhage (SAH) due to aneurysm rupture was evaluated in relation to CT findings in nine patients. Six patients were studied within 3 days and the other three patients were studied 4 to 6 days from the ictus of SAH using a 0.5 Tesla superconducting unit. In all of the patients, hematoma in the subarachnoid space and ventricles was demonstrated by the proton density-weighted spin echo sequence, which showed that bloody cerebrospinal fluid (CSF) had a higher signal intensity than brain tissue or normal CSF. Magnetic resonance imaging was more sensitive in detecting SAH and more informative as to the site of the ruptured aneurysm than CT. Despite some limitations in applying it to patients with acute SAH, magnetic resonace imaging has clear advantages in the diagnosis of SAH. (author)

  1. Magnetic resonance imaging of aneurysmal subarachnoid hemorrhage

    Energy Technology Data Exchange (ETDEWEB)

    Ogawa, Toshihide; Shimosegawa, Eku; Inugami, Atsushi; Shishido, Fumio; Fujita, Hideaki; Ito, Hiroshi; Uemura, Kazuo; Yasui, Nobuyuki (Research Inst. of Brain and Blood Vessels, Akita (Japan))

    1991-11-01

    Magnetic resonance imaging of subarachnoid hemorrhage (SAH) due to aneurysm rupture was evaluated in relation to CT findings in nine patients. Six patients were studied within 3 days and the other three patients were studied 4 to 6 days from the ictus of SAH using a 0.5 Tesla superconducting unit. In all of the patients, hematoma in the subarachnoid space and ventricles was demonstrated by the proton density-weighted spin echo sequence, which showed that bloody cerebrospinal fluid (CSF) had a higher signal intensity than brain tissue or normal CSF. Magnetic resonance imaging was more sensitive in detecting SAH and more informative as to the site of the ruptured aneurysm than CT. Despite some limitations in applying it to patients with acute SAH, magnetic resonace imaging has clear advantages in the diagnosis of SAH. (author).

  2. Evaluation of early coronary graft patency after coronary artery bypass graft surgery using multislice computed tomography angiography

    Directory of Open Access Journals (Sweden)

    Raissi Kamal

    2009-12-01

    Full Text Available Abstract Background Coronary artery bypass graft (CABG surgery is the standard of care in the treatment of advanced coronary artery disease, and its long-term results are affected by the failure of bypass grafts. The aim of the present study was to evaluate the early patency rate in coronary bypass grafts. Methods A total of 107 consecutive patients who underwent CABG were included in this study. Early graft patency was evaluated via computed tomography (CT angiography in the first week after surgery. Results There were a total of 366 grafts, comprised of 250 venous grafts and 116 arterial grafts. Multi-slice CT detected acute graft occlusions in 32 (8.7% of all the grafts, including 26 (10% of the 250 venous grafts and 6 (5% of the 116 arterial grafts. The patency rates obtained were 97.3% for the left internal mammary (IMA grafts, 50% for the radial artery grafts, and 50% for the right IMA grafts. Additionally, 107 (96.4% grafts to the left anterior descending artery (LAD were classified as patent, whereas 1 (30% of the 3 grafts in the left circumflex (LCX region and 1 (50% of the 2 grafts in the right coronary artery (RCA territory were found to be occluded. In the venous category, 8 (13.7% of the 58 grafts to LAD were found to be occluded. In the LCX region, 9 (8.5% of the 106 grafts were classified as occluded, while the remaining 97 (91.5% grafts were patent. The venous grafts to RCA were occluded in 9 (10.4% of the 86 grafts. Amongst the multiple preoperative, intraoperative, and postoperative factors, pump time was significantly longer in the patients with occluded grafts than in those with patent grafts (P = 0.04. Conclusion The IMA grafts had the highest early patency rate amongst the coronary bypass grafts. However, the other arterial grafts were associated with a high rate of acute occlusions.

  3. Computed tomography in ruptured intracranial aneurysm

    International Nuclear Information System (INIS)

    Suzuki, Michiyasu; Ogawa, Akira; Sakurai, Yoshiharu; Komatsu, Shinro; Suzuki, Jiro.

    1983-01-01

    The differences between initial bleeding and rebleeding due to ruptured intracranial aneurysm was investigated by CT. The study included 120 cases of ruptured cerebral aneurysm; 71 cases had only one bleeding and 49 cases had rebleeding. All the cases underwent CT examinations within 2 weeks following bleeding. Subarachnoid hemorrhages were classified into three groups according to the CT findings: Diffuse high type-high density areas in the entire basal cistern; Localized high type-high density area in a restricted part of the basal cistern; and Iso or Low type-no high density areas in the basal cistern. CT scans done within 24 hours following initial bleeding showed Diffuse high type in 96% of the cases and Localized high type in 4%. On the other hand, in rebleeding cases, Diffuse high type was 50%, Localized high type 25% and Iso or Low type 25%. In rebleeding cases within three days following initial bleeding, Diffuse high type was 90% and Iso or Low type 10%. However, between day 4 and day 14, Diffuse high type was 14%, Localized high type 42% and Iso or Low type 42%. After day 15, Diffuse high type was 36%, Localized type 36% and Iso or Low type 28%. Intracerebral hematoma and/or ventricular hemorrhage secondary to ruptured aneurysms were also investigated. Following initial bleeding, 18% of cases showed intracerebral and/or ventricular hemorrhage, however, the incidence increased up to 59% in rebleeding cases. These observations indicate that the subarachnoid hemorrhage due to re-ruptured aneurysm tends to be more localized than in initial bleeding cases and that intracerebral and/or ventricular hemorrhage seems more frequent in rebleeding cases. (author)

  4. Endovascular treatment of ruptured splenic artery aneurysm

    DEFF Research Database (Denmark)

    Bjerring, Ole Steen

    2008-01-01

    Splenic artery aneurysms (SAA) are traditionally treated surgically, but endovascular techniques are becoming increasingly popular. A 64 year-old male with chest pain and low blood pressure was admitted under suspicion of AMI. A CT scan showed a 56 mm SAA with signs of rupture. The patient...... was treated with endovascular embolisation of the SAA with coils. Blood pressure and haemoglobin levels were stabilized and the patient was discharged. In the case of rupture the treatment of choice seems to be endovascular....

  5. Bleeding aneurysms of the celiac trunk

    International Nuclear Information System (INIS)

    Ziviello, M.; D'Isa, L.; Siani, A.; Maglione, F.; Cataldo, B.; Ziviello, R.; Capalbogiliberti, R.

    1988-01-01

    The authors report their experience in the study of bleeding aneurysms of the celiac arteries. Eleven patients were examined with US,CT, and angiography (8 hepatic artery aneurysms and 3 splenic artery aneurysms). Clinical findings included digestive bleeding, upper abdominal pain, palpable pulsating masses, and jaundice. Patient history included blunt abdominal trauma, penetrating trauma due to gunshot, acute pancreatitis, recent hepatic biospy. In all cases US showed an abdominal mass ranging in size from 2 to 10 cm. US findings included cyst-like lesions (8 cases), anobulated solid-like lesion, and complex lesion (2 cases). Continuity of the lesion with adjancent arterial vessels was noted in 5/11 cases, and pulsing activity in 3/11 cases. US patterns, although not specific, play an important role in the diagnosis when associated to other elements such as arterial continuity, mass pulsatility, patient history, and gastrointestinal bleeding. They suggest the need for more specific imaging exams, i.e. CT and angiography, and help avoid dangerous diagnostic biopsies. CT was performed to confirm US findings in 5 cases, and detected either hypodense cystic masses, or inhomogeneous masses with arterial enhancement after bolus injection of cm. CT was used to better demonstrate the lumen, patency of the vessel, the walls of the vessel, and the parietal thrombotic component. The typical arterial enhancement was the decisive finding for the diagnosis, even though a total continuity with arterial vessels was never observed. Angiography was the method of choice for the preoperative demonstration of hepatic artery aneurysms (10 cases) and for occlusive treatment with Gianturco coils (3 cases)

  6. Thoracic type Ia endoleak: direct percutaneous coil embolization of the aortic arch at the blood entry site after TEVAR and double-chimney stent-grafts

    Energy Technology Data Exchange (ETDEWEB)

    Bangard, Christopher; Franke, Mareike; Maintz, David; Chang, De-Hua [University Hospital, University of Cologne, Department of Radiology, Cologne (Germany); Pfister, Roman [University Hospital, University of Cologne, Department of Internal Medicine III, Cologne (Germany); Deppe, Antje-Christin [University Hospital, University of Cologne, Department of Cardiothoracic Surgery, Cologne (Germany); Matoussevitch, Vladimir [University Hospital, University of Cologne, Department of Vascular Surgery, Cologne (Germany)

    2014-06-15

    To introduce a novel percutaneous technique to stop blood entry at the lesser aortic arch curvature by coil embolisation in type Ia endoleak after TEVAR. A 61-year-old Marfan patient presented with type Ia endoleak of the aortic arch and a growing aortic arch pseudoaneurysm after TEVAR. Multiple preceding operations and interventions made an endovascular approach unsuccessful. Direct percutaneous puncture of the aneurysmal sac would have cured the sign, but not the cause of blood entry at the lesser curvature of the aortic arch. Direct CT-guided percutaneous puncture of the blood entry site in the aortic arch with fluoroscopically guided coil embolisation using detachable extra-long coils was successfully performed. Three weeks after the intervention, the patient developed fever because of superinfection of the pseudoaneurysm. The blood cultures and CT-guided mediastinal aspirate were sterile. After intravenous administration of antibiotics, the fever disappeared and the patient recovered. Six-month follow-up showed permanent closure of the endoleak and a shrinking aneurysmal sac. Direct percutaneous puncture of the aortic arch at the blood entry site of a thoracic type Ia endoleak after TEVAR and double-chimney stent-grafts with coil embolisation of the wedge-shaped space between the lesser aortic curvature and the stent-graft is possible. (orig.)

  7. Thoracic type Ia endoleak: direct percutaneous coil embolization of the aortic arch at the blood entry site after TEVAR and double-chimney stent-grafts

    International Nuclear Information System (INIS)

    Bangard, Christopher; Franke, Mareike; Maintz, David; Chang, De-Hua; Pfister, Roman; Deppe, Antje-Christin; Matoussevitch, Vladimir

    2014-01-01

    To introduce a novel percutaneous technique to stop blood entry at the lesser aortic arch curvature by coil embolisation in type Ia endoleak after TEVAR. A 61-year-old Marfan patient presented with type Ia endoleak of the aortic arch and a growing aortic arch pseudoaneurysm after TEVAR. Multiple preceding operations and interventions made an endovascular approach unsuccessful. Direct percutaneous puncture of the aneurysmal sac would have cured the sign, but not the cause of blood entry at the lesser curvature of the aortic arch. Direct CT-guided percutaneous puncture of the blood entry site in the aortic arch with fluoroscopically guided coil embolisation using detachable extra-long coils was successfully performed. Three weeks after the intervention, the patient developed fever because of superinfection of the pseudoaneurysm. The blood cultures and CT-guided mediastinal aspirate were sterile. After intravenous administration of antibiotics, the fever disappeared and the patient recovered. Six-month follow-up showed permanent closure of the endoleak and a shrinking aneurysmal sac. Direct percutaneous puncture of the aortic arch at the blood entry site of a thoracic type Ia endoleak after TEVAR and double-chimney stent-grafts with coil embolisation of the wedge-shaped space between the lesser aortic curvature and the stent-graft is possible. (orig.)

  8. Mycotic pulmonary artery aneurysm as an unusual complication of thoracic actinomycosis

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Hyung-Soo; Lee, Sang-Yeub [Wonkwang University College, Iksan (Korea, Republic of); Oh, Yu-Whan; Noh, Hyung-Jun; Lee, Ki-Yeol; Kang, Eun-Young [Korea University Hospital and Korea University College, Seoul (Korea, Republic of)

    2004-03-15

    Although pulmonary artery aneurysms are a rare vascular anomaly, they are seen in a wide variety of conditions, such as congenital heart disease, infection, trauma, pulmonary hypertension, cystic medial necrosis and generalized vasculitis. To our knowledge, mycotic aneurysms caused by pulmonary actinomycosis have not been reported in the radiologic literature. Herein, a case of pulmonary actinomycosis complicated by mycotic aneurysm is presented. On CT scans, this case showed focal aneurysmal dilatation of a peripheral pulmonary artery within necrotizing pneumonia of the right lower lobe, which was successfully treated with transcatheter embolization using wire coils.

  9. Bilateral, Mirror-imaged, Postero-inferior Cerebellar Artery Aneurysms: Report of a Rare Case

    Directory of Open Access Journals (Sweden)

    G R Sharma

    2011-06-01

    Full Text Available A 60-year-old right-handed lady presented with the features of subarachnoid haemorrhage. The CT angiogram showed a pair of very rare bilateral, mirror-imaged distal postero-inferior cerebellar artery aneurysms. Both aneurysms were clipped via the midline posterior fossa craniectomy under general anaesthesia. The literatures is reviewed on the incidence, presentation, management and outcome of bilateral distal posterior-inferior cerebellar artery aneurysms. Keywords: bilateral mirror image, distal postero-inferior cerebellar artery aneurysms, posterior fossa craniectomy, microsurgical clipping

  10. Mycotic pulmonary artery aneurysm as an unusual complication of thoracic actinomycosis

    International Nuclear Information System (INIS)

    Kim, Hyung-Soo; Lee, Sang-Yeub; Oh, Yu-Whan; Noh, Hyung-Jun; Lee, Ki-Yeol; Kang, Eun-Young

    2004-01-01

    Although pulmonary artery aneurysms are a rare vascular anomaly, they are seen in a wide variety of conditions, such as congenital heart disease, infection, trauma, pulmonary hypertension, cystic medial necrosis and generalized vasculitis. To our knowledge, mycotic aneurysms caused by pulmonary actinomycosis have not been reported in the radiologic literature. Herein, a case of pulmonary actinomycosis complicated by mycotic aneurysm is presented. On CT scans, this case showed focal aneurysmal dilatation of a peripheral pulmonary artery within necrotizing pneumonia of the right lower lobe, which was successfully treated with transcatheter embolization using wire coils

  11. Multiple intracranial aneurysms following radiation therapy for pituitary adenoma

    International Nuclear Information System (INIS)

    Moriyama, Takumi; Shigemori, Minoru; Hirohata, Yu; Konishi, Jun; Yuge, Tatuo; Tokunaga, Takayuki; Kuramoto, Shinken.

    1992-01-01

    A rare case is reported in which multiple cerebral aneurysm occurred after radiotherapy. A female aged 51 was hospitalized with a chief complaint of consciousness disorder. The patient was discharged from the hospital 1 year before, after undergoing subtotal extirpation of a tumor through the transsphenoidal sinus in a case of pituitary adenoma, and post-operative radiotherapy (topical 50 Gy). Mild hyperlipidemia associated with hypothyroidism was observed by blood biochemical test during hospitalization. Multiple cerebral infarction was observed by CT scanning and MR imaging. Conservative treatment including intensified endocrine-supplementing treatment was performed. Thyroid gland function and hyperlipidemia improved, but the consciousness disorder occurred suddenly 6 weeks after hospitalization. Subarachnoid hemorrhage and hydrocephalus were observed by CT scanning. Cerebral angiography detected a saccular aneurysm in the trifuraction of the right middle cerebral artery, 3 fusiform aneurysms in the periphery of the right middle cerebral artery, 2 fusiform aneurysms in the posterior cerebral artery. These findings were not observed at the initial hospitalization but were unexceptionally confined to all the irradiation fields. The patient died 8 weeks after hospitalization, and no autoptic findings was obtained. We presumed that radiation vasculopathy, caused by radiation therapy done one year previously, had led to the occurrence of multiple cerebral aneurysms. We think that hyperlipidemia may have acted as an exacerbating factor responsible for these aneurysms. (author)

  12. Post eclamptic aneurysmal rupture subarachnoid haemorrhage diagnosed in the puerperium

    International Nuclear Information System (INIS)

    Coolen, Teresa

    2006-01-01

    The incidence of subarachnoid and/or intracerebral haemorrhage in women during pregnancy is rare. The risk depends on the stage of pregnancy, but seems to be highest during the late third trimester, during delivery and in the puerperium. Headache can be a symptom of both preeclampsia, subarachnoid haemorrhage and other pathologies or conditions. It is essential for pregnant women with a suspected ruptured aneurysm to be investigated and treated without delay, irrespective of fear of harm to the foetus, to avoid complications from aneurysm rupture. This case study presents a 39-year-old woman who was 35 weeks and 3 days pregnant with known preeclampsia. She endured a headache for the three days leading up to the delivery with associated diplopia on the third day, but these symptoms were thought to be related to her preeclampsia. Over the three hours following childbirth, her headache became more severe and she suffered from vomiting, loss of vision, torticollis and seizures. Computed tomography (CT) of her head revealed a subarachnoid haemorrhage while CT angiography of the Circle of Willis failed to reveal an aneurysm and 4-vessel angiography only demonstrated an area slightly suspicious for the presence of an aneurysm. 3D rotational angiography clearly demonstrated a 1-2 mm aneurysm superior to the left terminal internal carotid artery. In this case, 3D rotational angiography proved to be a valuable additional technique. This patient underwent surgery for her ruptured aneurysm and has made an excellent recovery

  13. High risk endovascular aneurysm repair: a case report.

    Science.gov (United States)

    De Silva, Samanthi

    2017-10-01

    Mr AB is a 66-year old gentleman who presented for elective endovascular aneurysm repair (EVAR) following a routine screening scan identifying a 5.5cm abdominal aortic aneurysm (AAA). He had a past history of chronic obstructive pulmonary disease (COPD) with FEV1/FVC ratio of 48% on pre-assessment. He was hypertensive with a history of ischaemic heart disease (IHD), which has remained asymptomatic following coronary artery bypass grafting (CABG) eight years prior to this presentation. Copyright the Association for Perioperative Practice.

  14. Rupture of true profunda femoris artery aneurysms. Two new cases

    DEFF Research Database (Denmark)

    Levi-Mazloum, Niels Donald; Schroeder, T V

    1996-01-01

    Atherosclerotic aneurysms of the deep femoral artery are very rare. We report the first 2 published Scandinavian cases. Both were present in elderly smoking men. They presented with acute local pain, swelling and circulatory collapse. Ultrasonography and angiography demonstrated femoral aneurysm ...... but it was only at operation that the relation to the deep femoral artery was established. Simple ligation of the deep femoral artery was performed in one case. The other patient had a 6 mm PTFE graft interpositioned. Both made an uneventful recovery....

  15. Acute retroperitoneal bleeding due to inferior mesenteric artery aneurysm: Case report

    Directory of Open Access Journals (Sweden)

    Ferrón JA

    2010-06-01

    Full Text Available Abstract Background Visceral artery aneurysms (VAA, although uncommon, are increasingly being detected. We describe a case of spontaneous retroperitoneal hemorrhage from a ruptured IMA aneurysm associated with stenosis of the superior mesenteric artery (SMA and celiac trunk, successfully treated with surgery. Methods A 65-year-old man presented with abdominal pain and hypovolemic shock. Abdominal CT scan showed an aneurysm of the inferior mesenteric artery with retroperitoneal hematoma. In addition, an obstructive disease of the superior mesenteric artery and celiac axis was observed. Results Upon emergency laparotomy a ruptured inferior mesenteric artery aneurysm was detected. The aneurysm was excised and the artery reconstructed by end-to-end anastomosis. Conclusions This report discusses the etiology, presentation, diagnosis and case management of inferior mesenteric artery aneurysms.

  16. An unusual, duplicate origin of the anterior choroidal artery with aneurysm: a case report.

    Science.gov (United States)

    Chenin, Louis; Chivot, Cyril; Toussaint, Patrick; Deramond, Hervé; Peltier, Johann

    2015-12-01

    Aneurysms of the anterior choroidal artery (AChoA) are rare and often difficult to treat. Variations may be present and must be identified prior to treatment. We report a unique case of a ruptured aneurysm located at the origin of a duplicate branch of the AChoA. A 56-year-old male was admitted to our university hospital for coma. A brain CT scan showed a subarachnoid hemorrhage, and CT angiography revealed a duplication of the right AChoA, with an aneurysm located at the branch's origin. We decided to embolize this aneurysm. Four weeks later, our patient was able to transfer to the rehabilitation unit. To the best of our knowledge, this is one of the first descriptions of an aneurysm located at the origin of a duplicate branch of the AChoA.

  17. Endovascular repair of para-anastomotic aortoiliac aneurysms.

    LENUS (Irish Health Repository)

    Tsang, Julian S

    2009-11-01

    The purpose of this study is to evaluate the use of endovascular stent grafts in the treatment of para-anastomotic aneurysms (PAAs) as an alternative to high-risk open surgical repair. We identified all patients with previous open aortic aneurysm repair who underwent infrarenal endovascular aneurysm repair (EVAR) at our institution from June 1998 to April 2007. Patient demographics, previous surgery, and operative complications were recorded. One hundred forty-eight patients underwent EVAR during the study period and 11 patients had previous aortic surgery. Of these 11 redo patients, the mean age was 62 years at initial surgery and 71 years at EVAR. All patients were male. Initial open repair was for rupture in five (45%) patients. The average time between initial and subsequent reintervention was 9 years. All patients were ASA Grade III or IV. Fifty-five percent of the PAAs involved the iliac arteries, 36% the abdominal aorta, and 9% were aortoiliac. Ten patients had endovascular stent-grafts inserted electively, and one patient presented with a contained leak. Aorto-uni-iliac stent-grafts were deployed in seven patients, and bifurcated stent-grafts in four patients. A 100% successful deployment rate was achieved. Perioperative mortality was not seen and one patient needed surgical reintervention to correct an endoleak. Endovascular repair of PAAs is safe and feasible. It is a suitable alternative and has probably now become the treatment of choice in the management of PAAs.

  18. Source of errors and accuracy of a two-dimensional/three-dimensional fusion road map for endovascular aneurysm repair of abdominal aortic aneurysm.

    Science.gov (United States)

    Kauffmann, Claude; Douane, Frédéric; Therasse, Eric; Lessard, Simon; Elkouri, Stephane; Gilbert, Patrick; Beaudoin, Nathalie; Pfister, Marcus; Blair, Jean François; Soulez, Gilles

    2015-04-01

    To evaluate the accuracy and source of errors using a two-dimensional (2D)/three-dimensional (3D) fusion road map for endovascular aneurysm repair (EVAR) of abdominal aortic aneurysm. A rigid 2D/3D road map was tested in 16 patients undergoing EVAR. After 3D/3D manual registration of preoperative multidetector computed tomography (CT) and cone beam CT, abdominal aortic aneurysm outlines were overlaid on live fluoroscopy/digital subtraction angiography (DSA). Patient motion was evaluated using bone landmarks. The misregistration of renal and internal iliac arteries were estimated by 3 readers along head-feet and right-left coordinates (z-axis and x-axis, respectively) before and after bone and DSA corrections centered on the lowest renal artery. Iliac deformation was evaluated by comparing centerlines before and during intervention. A score of clinical added value was estimated as high (z-axis 5 mm). Interobserver reproducibility was calculated by the intraclass correlation coefficient. The lowest renal artery misregistration was estimated at x-axis = 10.6 mm ± 11.1 and z-axis = 7.4 mm ± 5.3 before correction and at x-axis = 3.5 mm ± 2.5 and z-axis = 4.6 mm ± 3.7 after bone correction (P = .08), and at 0 after DSA correction (P artery was estimated at x-axis = 2.4 mm ± 2.0 and z-axis = 2.2 mm ± 2.0. Score of clinical added value was low (n = 11), good (n= 0), and high (n= 5) before correction and low (n = 5), good (n = 4), and high (n = 7) after bone correction. Interobserver intraclass correlation coefficient for misregistration measurements was estimated at 0.99. Patient motion before stent graft delivery was estimated at x-axis = 8 mm ± 5.8 and z-axis = 3.0 mm ± 2.7. The internal iliac artery misregistration measurements were estimated at x-axis = 6.1 mm ± 3.5 and z-axis = 5.6 mm ± 4.0, and iliac centerline deformation was estimated at 38.3 mm ± 15.6. Rigid registration is feasible and fairly accurate. Only a partial reduction of vascular

  19. Hepatic artery aneurysm repair: a case report

    Directory of Open Access Journals (Sweden)

    Jaunoo SS

    2009-01-01

    Full Text Available Abstract Introduction Hepatic artery aneurysms remain a clinically significant entity. Their incidence continues to rise slowly and mortality from spontaneous rupture is high. Repair is recommended in those aneurysms greater than 2 cm in diameter. It is not surprising that vascular comorbidities, such as ischaemic heart disease, are common in surgical patients, particularly those with arterial aneurysms such as these. The decision of when to operate on patients who require urgent surgery despite having recently suffered an acute coronary syndrome remains somewhat of a grey and controversial area. We discuss the role of delayed surgery and postoperative followup of this vascular problem. Case presentation A 58-year-old man was admitted with a 5.5 cm hepatic artery aneurysm. The aneurysm was asymptomatic and was an incidental finding as a result of an abdominal computed tomography scan to investigate an episode of haemoptysis (Figure 1. Three weeks prior to admission, the patient had suffered a large inferior myocardial infarction and was treated by thrombolysis and primary coronary angioplasty. Angiographic assessment revealed a large aneurysm of the common hepatic artery involving the origins of the hepatic, gastroduodenal, left and right gastric arteries and the splenic artery (Figures 2 and 3. Endovascular treatment was not considered feasible and immediate surgery was too high-risk in the early post-infarction period. Therefore, surgery was delayed for 3 months when aneurysm repair with reconstruction of the hepatic artery was successfully performed. Graft patency was confirmed with the aid of an abdominal arterial duplex. Plasma levels of conventional liver function enzymes and of alpha-glutathione-S-transferase were within normal limits. This was used to assess the extent of any hepatocellular damage perioperatively. The patient made a good recovery and was well at his routine outpatient check-ups. Conclusion There is no significant

  20. Surgical treatment of pararenal aortic aneurysms in the elderly.

    Science.gov (United States)

    Illuminati, G; D'Urso, A; Ceccanei, G; Caliò, F; Vietri, F

    2007-12-01

    Until fenestrated endografts will become the standard treatment of pararenal aortic aneurysms, open surgical repair will currently be employed for the repair of this condition. Suprarenal aortic control and larger surgical dissection represent additional technical requirements for the treatment of pararenal aneurysms compared to those of open infrarenal aortic aneurysms, which may be followed by an increased operative mortality and morbidity rate. As this may be especially true when dealing with pararenal aneurysms in an elderly patients' population, we decided to retrospectively review our results of open pararenal aortic aneurysm repair in elderly patients, in order to compare them with those reported in the literature. Twenty-one patients over 75 years of age were operated on for pararenal aortic aneurysms in a ten-year period. Exposure of the aorta was obtained by means of a retroperitoneal access, through a left flank incision on the eleventh rib. When dealing with interrenal aortic aneurysm the left renal artery was revascularized with a retrograde bypass arising from the aortic graft, proximally bevelled on the ostium of the right renal artery. Two patients died of acute intestinal ischemia, yielding a postoperative mortality of 9.5%. Nonfatal complications included 2 pleural effusions, a transitory rise in postoperative serum creatinine levels in 3 cases, and one retroperitoneal hematoma. Mean renal ischemia time was 23 min, whereas mean visceral ischemia time was 19 min. Mean inhospital stay was 11 days. Pararenal aortic aneurysms in the elderly can be surgically repaired with results that are similar to those obtained in younger patients.

  1. Case of radiation induced aneurysm of extracranial carotid artery

    Energy Technology Data Exchange (ETDEWEB)

    Tashiro, Takashi; Ikota, Toshio; Yamashita, Kousuke; Kodama, Takao

    1988-08-01

    An unusual case of post-irradiation aneurysm of extracranial internal carotid artery is presented. A 70-year-old man, complaining of left cervical throbbing mass with focal pain, was admitted on February 8, 1985. It was noted, from his past history, that he had had surgery of the removal of cervical lymphnodes and that unknown dosage of irradiation had been added to the cervical region 30 years before. Left carotid angiography (on admission) demonstrated a giant aneurysm in the cervical portion of internal carotid artery. Right carotid angiography with compression of left carotid artery revealed good cross filling through anterior communicating artery. Computed tomography with contrast media showed a ring like enhanced mass, which was thought to suggest that a large part of the aneurysm was filled with intraluminal thrombosis. During 30 days of evaluation, the aneurysm grew larger and his cervical pain became untolerable. Operation, the resection of the aneurysm and the reconstruction (of circulation) with vein graft, was challenged on March 12. It was so difficult with meticulous work that the ligation of left common carotid artery was performed after all. Seven days after the operation, he suffered from the gastrointestinal bleeding, which was enough to lead him to hypovolemic shock. Thereafter, right hemiparesis and aphasia were brought about. Two months later, he died of pneumonia. On histological examination, it was demonstrated that the aneurysm communicated with the necrotic tissue and that the normal structure of the blood vessel was not observed in the aneurysmal wall and consisted of the collagenous fiber and granulated tissue. The aneurysm was interpreted as a false one.

  2. A case of radiation induced aneurysm of extracranial carotid artery

    International Nuclear Information System (INIS)

    Tashiro, Takashi; Ikota, Toshio; Yamashita, Kousuke; Kodama, Takao

    1988-01-01

    An unusual case of post-irradiation aneurysm of extracranial internal carotid artery is presented. A 70-year-old man, complaining of left cervical throbbing mass with focal pain, was admitted on February 8, 1985. It was noted, from his past history, that he had had surgery of the removal of cervical lymphnodes and that unknown dosage of irradiation had been added to the cervical region 30 years before. Left carotid angiography (on admission) demonstrated a giant aneurysm in the cervical portion of internal carotid artery. Right carotid angiography with compression of left carotid artery revealed good cross filling through anterior communicating artery. Computed tomography with contrast media showed a ring like enhanced mass, which was thought to suggest that a large part of the aneurysm was filled with intraluminal thrombosis. During 30 days of evaluation, the aneurysm grew larger and his cervical pain became untolerable. Operation, the resection of the aneurysm and the reconstruction (of circulation) with vein graft, was challenged on March 12. It was so difficult with meticulous work that the ligation of left common carotid artery was performed after all. Seven days after the operation, he suffered from the gastrointestinal bleeding, which was enough to lead him to hypovolemic shock. Thereafter, right hemiparesis and aphasia were brought about. Two months later, he died of pneumonia. On histological examination, it was demonstrated that the aneurysm communicated with the necrotic tissue and that the normal structure of the blood vessel was not observed in the aneurysmal wall and consisted of the collagenous fiber and granulated tissue. The aneurysm was interpreted as a false one. (author)

  3. Endovascular Aneurysm Repair and Sealing (EVARS): A Useful Adjunct in Treating Challenging Morphology

    Energy Technology Data Exchange (ETDEWEB)

    Harrison, Gareth J., E-mail: garethjamesharrison@yahoo.co.uk; Antoniou, George A., E-mail: antoniou.ga@hotmail.com; Torella, Francesco, E-mail: francesco.torella@rlbuht.nhs.uk; McWilliams, Richard G., E-mail: richard.mcwilliams@rlbuht.nhs.uk; Fisher, Robert K., E-mail: robert.fisher@rlbuht.nhs.uk [Royal Liverpool University Hospital, Liverpool Vascular and Endovascular Service (United Kingdom)

    2016-04-15

    An 81-year-old male with previous open abdominal aortic aneurysm repair presented with asymptomatic large pseudoaneurysms at both ends of an open surgical tube graft. Endovascular aneurysm sealing (EVAS) in combination with the iliac limbs of a standard endovascular aneurysm repair (EVAR) successfully excluded both pseudoaneurysms from circulation. We describe the combination of elements of EVAS and EVAR and have termed this endovascular aneurysm repair and sealing (EVARS). EVARS has the advantage of harnessing the benefits of endobag sealing in aortic necks unsuitable for standard EVAR whilst providing the security of accurate stent placement within short common iliac arteries. In conclusion, EVAS may be combined with standard endovascular iliac limbs and is a possible treatment option for pseudoaneurysm following open aneurysm repair.

  4. Hybrid treatment of a true thyreocervical trunk aneurysm in a patient with Type B aortic dissection

    Directory of Open Access Journals (Sweden)

    Nikolaos G Baikoussis

    2016-01-01

    Full Text Available We would like to describe a case with a complex aortic disease treated in hybrid fashion. We present an interesting case of a 65-year-old man with a medical history of hypertension, hyperlipidemia, and coronary artery disease percutaneously treated. An acute Type B aortic dissection occurred and treated with the implantation of a stent-graft which occluded the left subclavian artery due to its extension to the aortic arch. This event required a carotid-subclavian artery bypass due to ischemia of the left arm. An aneurysm in the innominate artery also detected, was treated with another stent-graft implantation 3 months later. At 5-year follow-up, an aneurysm of the thyreocervical trunk was found while the stent-graft of the aorta was well-tolerated without endoleak and the carotid-subclavian graft was patent. The aneurysm was asymptomatic but considering the risk of spontaneous rupture of an aneurysm of this size, elective surgery was indicated. Because the aneurysm was very close to the brachiocephalic bifurcation, open surgical repair would require a sternotomy. The right common carotid artery and right subclavian artery were exposed. The thyrocervical trunk, right internal mammary artery and right vertebral artery were occluded by ligations to isolate the aneurysm. An 8-mm Dacron graft was anastomosed end-to-end to the distal part of subclavian artery. We would like through this case, discuss the role of the hybrid cardiovascular surgery to minimize the postoperative complications in complex cardiovascular pathology. We also discuss the international bibliography about the thyreocervical trunk aneurysm and the treatment options.

  5. A multimodality vascular imaging phantom of an abdominal aortic aneurysm with a visible thrombus

    Energy Technology Data Exchange (ETDEWEB)

    Allard, Louise; Chayer, Boris; Qin Zhao [Laboratory of Biorheology and Medical Ultrasonics, Research Center, University of Montreal Hospital (CRCHUM), Quebec H2L 2W5 (Canada); Soulez, Gilles [Department of Radiology, University of Montreal Hospital (CHUM), Quebec H2L 2M1 (Canada); Department of Radiology, Radio-Oncology and Nuclear Medicine, University of Montreal, Quebec H3T 1J4 (Canada); Institute of Biomedical Engineering, University of Montreal, Quebec H3T 1J4 (Canada); Roy, David [Institute of Biomedical Engineering, University of Montreal, Quebec H3T 1J4 (Canada); Cloutier, Guy [Laboratory of Biorheology and Medical Ultrasonics, Research Center, University of Montreal Hospital (CRCHUM), Quebec H2L 2W5 (Canada); Department of Radiology, Radio-Oncology and Nuclear Medicine, University of Montreal, Quebec H3T 1J4 (Canada); Institute of Biomedical Engineering, University of Montreal, Quebec H3T 1J4 (Canada)

    2013-06-15

    Purpose: With the continuous development of new stent grafts and implantation techniques, it has now become technically feasible to treat abdominal aortic aneurysms (AAA) with challenging anatomy using endovascular repair with standard, fenestrated, or branched stent-grafts. In vitro experimentations are very useful to improve stent-graft design and conformability or imaging guidance for stent-graft delivery or follow-up. Vascular replicas also help to better understand the limitation of endovascular approaches in challenging anatomy and possibly improve surgical planning or training by practicing high risk clinical procedures in the laboratory to improve outcomes in the operating room. Most AAA phantoms available have a very basic anatomy, which is not representative of the clinical reality. This paper presents a method of fabrication of a realistic AAA phantom with a visible thrombus, as well as some mechanical properties characterizing such phantom. Methods: A realistic AAA geometry replica of a real patient anatomy taken from a multidetector computed tomography (CT) scan was manufactured. To demonstrate the multimodality imaging capability of this new phantom with a thrombus visible in magnetic resonance (MR) angiography, CT angiography (CTA), digital subtraction angiography (DSA), and ultrasound, image acquisitions with all these modalities were performed by using standard clinical protocols. Potential use of this phantom for stent deployment was also tested. A rheometer allowed defining hyperelastic and viscoelastic properties of phantom materials. Results: MR imaging measurements of SNR and CNR values on T1 and T2-weighted sequences and MR angiography indicated reasonable agreement with published values of AAA thrombus and abdominal components in vivo. X-ray absorption also lay within normal ranges of AAA patients and was representative of findings observed on CTA, fluoroscopy, and DSA. Ultrasound propagation speeds for developed materials were also in

  6. A multimodality vascular imaging phantom of an abdominal aortic aneurysm with a visible thrombus

    International Nuclear Information System (INIS)

    Allard, Louise; Chayer, Boris; Qin Zhao; Soulez, Gilles; Roy, David; Cloutier, Guy

    2013-01-01

    Purpose: With the continuous development of new stent grafts and implantation techniques, it has now become technically feasible to treat abdominal aortic aneurysms (AAA) with challenging anatomy using endovascular repair with standard, fenestrated, or branched stent-grafts. In vitro experimentations are very useful to improve stent-graft design and conformability or imaging guidance for stent-graft delivery or follow-up. Vascular replicas also help to better understand the limitation of endovascular approaches in challenging anatomy and possibly improve surgical planning or training by practicing high risk clinical procedures in the laboratory to improve outcomes in the operating room. Most AAA phantoms available have a very basic anatomy, which is not representative of the clinical reality. This paper presents a method of fabrication of a realistic AAA phantom with a visible thrombus, as well as some mechanical properties characterizing such phantom. Methods: A realistic AAA geometry replica of a real patient anatomy taken from a multidetector computed tomography (CT) scan was manufactured. To demonstrate the multimodality imaging capability of this new phantom with a thrombus visible in magnetic resonance (MR) angiography, CT angiography (CTA), digital subtraction angiography (DSA), and ultrasound, image acquisitions with all these modalities were performed by using standard clinical protocols. Potential use of this phantom for stent deployment was also tested. A rheometer allowed defining hyperelastic and viscoelastic properties of phantom materials. Results: MR imaging measurements of SNR and CNR values on T1 and T2-weighted sequences and MR angiography indicated reasonable agreement with published values of AAA thrombus and abdominal components in vivo. X-ray absorption also lay within normal ranges of AAA patients and was representative of findings observed on CTA, fluoroscopy, and DSA. Ultrasound propagation speeds for developed materials were also in

  7. Giant left coronary ostial aneurysm after modified Bentall procedure in a Marfan patient.

    Science.gov (United States)

    Okamoto, Kazuma; Casselman, Filip P; De Geest, Raphael; Vanermen, Hugo

    2008-12-01

    We performed surgical repair of a giant left coronary ostial aneurysm after aortic root replacement using composite valve graft (modified Bentall procedure) in a patient with Marfan syndrome. Aneurysmal formation in the left main stem itself is very rare. In order to avoid mobilizing the coronary ostium from severe adhesions after previous surgery and to reduce the tension on the anastomosis, the left main trunk was reconstructed using an interposition Dacron graft. In aortic root surgeries in Marfan patients, the size of the side hole on the composite graft should be kept relatively small to fit the diameter of the native coronary arteries for prevention of coronary buttons from forming aneurysms at the level of the coronary button anastomosis. In addition, close observation to the coronary button anastomosis is indispensable in postoperative check-up.

  8. Mycotic aneurysm of the superior mesenteric artery after septic embolism

    International Nuclear Information System (INIS)

    Schmidt, F.; Dinkel, H.P.

    2002-01-01

    Mycotic aneurysms of the aorta and the visceral arteries are life-threatening diseases, due to potential rupture and organ or limb ischemia. They occur in endocarditis, immunodeficiency, bacteremia and fungemia, and have a poor prognosis.We report on a case of a 54-year-old male patient suffering from abdominal angina after mitral valve replacement for septic mycotic endocarditis. In presence of a mycotic-embolic occlusion of the left popliteal artery and multiple septic organ infarctions a mycotic aneurysm of the superior mesenteric artery was found in abdominal spiral-CT.Based on sequential spiral-CT examinations, this case demonstrates the development of a septic aneurysm of the superior mesenteric artery. (orig.) [de

  9. PET/CT and vascular disease: Current concepts

    Energy Technology Data Exchange (ETDEWEB)

    Cavalcanti Filho, Jose Leite Gondim; Souza Leao Lima, Ronaldo de [CDPI and Multi-Imagem Clinics, Rio de Janeiro (Brazil); Department of Radiology, Rio de Janeiro Federal University (UFRJ), Rio de Janeiro (Brazil); Souza Machado Neto, Luiz de [CDPI and Multi-Imagem Clinics, Rio de Janeiro (Brazil); Kayat Bittencourt, Leonardo, E-mail: lkayat@terra.com.br [CDPI and Multi-Imagem Clinics, Rio de Janeiro (Brazil); Department of Radiology, Rio de Janeiro Federal University (UFRJ), Rio de Janeiro (Brazil); Cortes Domingues, Romeu [CDPI and Multi-Imagem Clinics, Rio de Janeiro (Brazil); Fonseca, Lea Mirian Barbosa da [CDPI and Multi-Imagem Clinics, Rio de Janeiro (Brazil); Department of Radiology, Rio de Janeiro Federal University (UFRJ), Rio de Janeiro (Brazil)

    2011-10-15

    Since its introduction in 2001, positron emission tomography associated to computed tomography (PET/CT) has been established as a standard tool in cancer evaluation. Being a multimodality imaging method, it combines in a single session the sensitivity granted by PET for detection of molecular targets within the picomolar range, with an underlying submilimetric resolution inherent to CT, that can precisely localize the PET findings. In this last decade, there have been new insights regarding the pathophysiology of atherosclerosis, particularly about plaque rupture and vascular remodeling. This has increased the interest for research on PET/CT in vascular diseases as a potential new diagnostic tool, since some PET molecular targets could identify diseases before the manifestation of gross anatomic features. In this review, we will describe the current applications of PET/CT in vascular diseases, emphasizing its usefulness in the settings of vasculitis, aneurysms, vascular graft infection, aortic dissection, and atherosclerosis/plaque vulnerability. Although not being properly peripheral vascular conditions, ischemic cardiovascular disease and cerebrovascular disease will be briefly addressed as well, due to their widespread prevalence and importance.

  10. Brachial Artery Aneurysm as a Limb Threatening Condition: a Case Report

    Directory of Open Access Journals (Sweden)

    Farhad Heydari

    2015-05-01

    Full Text Available Brachial artery aneurysms are rare but potentially limb threatening condition. The presented case here is a 52-year old male referred to the emergency department complaining a sudden onset and progressive pain with coldness of his right upper extremity during brushing. The right upper extremity was pulseless and three-dimensional computed tomography showed an aneurysm of the proximal right brachial artery associated with arterial occlusion in its distal branch. Embolectomy was done, the aneurysm resected, and the artery successfully re-vascularised by interposing a saphenous vein graft

  11. Epidemiological study of 183 patients with spontaneous rupture of cerebral aneurysm

    International Nuclear Information System (INIS)

    Antonova, D.; Tasheva, E.

    2015-01-01

    Cerebral vessels aneurysms represent a significant part of the cerebral vessels pathology. There is no extensive study on that in Bulgaria. We present a study of 183 patients with spontaneous rupture of cerebral aneurysm, diagnosed and treated in UMHATEM ‘Pirogov’, Sofia. We used clinical methods - data from subject history, analysis of the accompanying documentation, subject medical chart; imaging-diagnostics methods - CT, DSA and MRI; and statistical methods. A total of 183 patients with ruptured intracranial aneurysms were studied. 65% were females and 35% were men.The ration female/male is 1.86, The mean age of all patients is 53.1 ±10.1 years. The highest incidence of ruptured aneurysms is seen in the age group 50 to 59 years. Aneurysms of a. cerebri media and a. communicants anterior are the most frequent (63.4% in total); while the lest are those of a basilaris (4.9%). 88.5% of the aneurysms in the studied group are small, 9.8% are large and 1.6% are giant. Intracranial hematomas are seen in 13.1% of the patients with ruptured aneurysms. Most frequently hematomas are connected with a. cerebri media and a.communicants anterior (87.5% in total). Patients with multiple aneurysms are 11.5% in total, 85.7% of them with an aneurysm of a.cerebri media. The incidence of ruptured cerebral aneurysms is higher amongst female. Frequency in the fifth decade of life is the highest. Most often seen are the aneurysms of a. cerebri media and a. communicants anterior, and the least - those of a. basilaris. Intracranial hematomas most frequently are associated with ruptures of a. cerebri media and a. communicants anterior, in patients with multiple aneurysms the highest is the frequency of aneurysms of a. cerebri media. (authors)

  12. Volume changes of extremely large and giant intracranial aneurysms after treatment with flow diverter stents

    Energy Technology Data Exchange (ETDEWEB)

    Carneiro, Angelo; Byrne, James V. [ohn Radcliffe Hospital, Oxford Neurovascular and Neuroradiology Research Unit, Nuffield Department of Surgical Sciences, Oxford (United Kingdom); Rane, Neil; Kueker, Wilhelm; Cellerini, Martino; Corkill, Rufus [John Radcliffe Hospital, Department of Neuroradiology, Oxford (United Kingdom)

    2014-01-15

    This study assessed volume changes of unruptured large and giant aneurysms (greatest diameter >20 mm) after treatment with flow diverter (FD) stents. Clinical audit of the cases treated in a single institution, over a 5-year period. Demographic and clinical data were retrospectively collected from the hospital records. Aneurysm volumes were measured by manual outlining at sequential slices using computerised tomography (CT) or magnetic resonance (MR) angiography data. The audit included eight patients (seven females) with eight aneurysms. Four aneurysms involved the cavernous segment of the internal carotid artery (ICA), three the supraclinoid ICA and one the basilar artery. Seven patients presented with signs and symptoms of mass effect and one with seizures. All but one aneurysm was treated with a single FD stent; six aneurysms were also coiled (either before or simultaneously with FD placement). Minimum follow-up time was 6 months (mean 20 months). At follow-up, three aneurysms decreased in size, three were unchanged and two increased. Both aneurysms that increased in size showed persistent endosaccular flow at follow-up MR; in one case, failure was attributed to suboptimal position of the stent; in the other case, it was attributed to persistence of a side branch originating from the aneurysm (similar to the endoleak phenomenon of aortic aneurysms). At follow-up, five aneurysms were completely occluded; none of these increased in volume. Complete occlusion of the aneurysms leads, in most cases, to its shrinkage. In cases of late aneurysm growth or regrowth, consideration should be given to possible endoleak as the cause. (orig.)

  13. A Giant Scapular Aneurysmal Bone Cyst in a Child

    Directory of Open Access Journals (Sweden)

    Theodoros Beslikas

    2012-01-01

    Full Text Available Aneurysmal bone cysts (ABCs are rare benign bone tumours. Scapula is a very rare location, and the relative literature is sparse. The purpose of this study is to present a case of a giant aggressive scapular aneurysmal bone cyst in a child. A 7-year-old boy presented to our hospital with pain and a palpated mass on the right scapula. Imaging studies (radiographs computed tomography scintigraphy were indicative of aneurysmal bone cyst. We performed curettage and bone grafting after the diagnosis was set by pathological examination through a posterior shoulder approach. Five years later, the patient has only residual signs of the lesion on radiographic control without signs of recurrence.

  14. Aneurysmal bone cyst of the acromion: a case report

    International Nuclear Information System (INIS)

    Ruggieri, M.; Milone, P.; Smilari, P.; Sessa, G.; Pavone, V.; Vasquez, E.

    1995-01-01

    The case of 6-year-old girl with an asymptomatic aneurysmal bone cyst of the acromion is reported. Such tumors are rarely located in the scapula and are especially rare in the acromion. The diagnosis was confirmed by biopsy and surgical resection of the lesion. Roentgenographic, CT and histologic features of the cyst are discussed. (orig.)

  15. Computed tomography in the evaluation of spinal aneurysmal bone cyst

    Energy Technology Data Exchange (ETDEWEB)

    Gouliamos, A.; Kalovidouris, A.; Vlahos, L.; Pontifex, G.; Papavassiliou, C.; Carvounis, E.; Deligeorgi-Politi, H.

    1986-11-01

    Computed tomographic findings in three cases of aneurysmal bone cyst (ABC) are reported. Although conventional radiography is usually adequate in the demonstration of an expansile osteolytic cavity, CT may provide additional information about tumour characteristics, localization and extent, show the lesion's relation to the spinal cord and thus be of great help in preoperative planning.

  16. True posterior communicating artery aneurysms: are they more prone to rupture? A biomorphometric analysis.

    Science.gov (United States)

    He, Wenzhuan; Hauptman, Jason; Pasupuleti, Latha; Setton, Avi; Farrow, Maria G; Kasper, Lydia; Karimi, Reza; Gandhi, Chirag D; Catrambone, Jeffrey E; Prestigiacomo, Charles J

    2010-03-01

    Posterior communicating artery (PCoA) aneurysms can occur at the junction with the internal carotid artery, posterior cerebral artery (PCA), or the proximal PCoA itself. Hemodynamic stressors contribute to aneurysm formation and may be associated with parent vessel size and aneurysm location. This study evaluates the correlation of various biomorphometric characteristics in 2 of the aforementioned types of PCoA aneurysms. Patients with PCoA aneurysms were analyzed using CT angiography. Source images and reconstructions were used to determine which aneurysms originated purely from the PCoA and those that originated from the internal carotid artery/PCoA junction. Morphometric analysis was performed on the aneurysm, the precommunicating segment of the PCA (P(1)), the ambient segment of the PCA (P(2)), and both PCoA arteries and were correlated to clinical presentation. Parametric and nonparametric analyses were performed to test for significance. A total of 77 PCoA aneurysms were analyzed, and 10 were found to be true PCoA aneurysms (13.0%). The ipsilateral PCoA/P(1) ratio (1.77 +/- 0.44 vs 0.82 +/- 0.46, p = 0.0001) and ipsilateral P(2)/P(1) ratio (1.73 +/- 0.40 vs 1.22 +/- 0.41, p = 0.0003) were significantly larger in true PCoA aneurysms. Interestingly, aneurysm size was statistically larger in the junctional aneurysms (0.14 +/- 0.1 vs 0.072 +/- 0.04 cm(3), p = 0.03). The prevalence of ruptured aneurysms was similar in both groups (approximately 80%, p value not significant). These data suggest that true PCoA aneurysms have a larger PCoA relative to the ipsilateral P(1) segment. To the authors' knowledge, this represents the first such biomorphometric comparison of these different types of PCoA aneurysms. Although statistically smaller in size, true PCoA aneurysms also have a similar prevalence of presenting as a ruptured aneurysm, suggesting that they might be more prone to rupture than a junctional aneurysms of similar size. Further analysis will be required to

  17. Unruptured Brain Aneurysms

    Science.gov (United States)

    ... treated with either endovascular coiling or open surgical clipping. However, if the unruptured aneurysm is treated successfully, ... Medical Advisory Board Publications BAF Newsletters Annual Reports News Public Service Announcements Press Releases Blog Administrative Tax ...

  18. Aneurysm of the superior mesenteric artery

    Energy Technology Data Exchange (ETDEWEB)

    Gebauer, A

    1984-11-01

    This is a report about 4 patients with aneurysms of the superior mesenteric artery of arteriosclerotic, mycotic and probably congenital etiology together with a review of the literature as to the etiology, diagnostic possibilities and therapy. Arteriography is the method of choice even though a diagnosis may be possible by sonography or CT in special cases. Even though an aneurysm of the superior mesenteric artery is rare, it has to be considered in the differential diagnosis of persisting abdominal problems of unknown origin. This is especially true for patients with a predisposing history such as previous or existing endocarditis, sepsis, arteriosclerosis and hypertension. Because of the possibility of rupture followed by life threating bleeding an adequate diagnostic step such as arteriography has to be considered finally.

  19. Aneurysm of the superior mesenteric artery

    International Nuclear Information System (INIS)

    Gebauer, A.

    1984-01-01

    This is a report about 4 patients with aneurysms of the superior mesenteric artery of arteriosclerotic, mycotic and probably congenital etiology together with a review of the literature as to the etiology, diagnostic possibilities and therapy. Arteriography is the method of choice even though a diagnosis may be possible by sonography or CT in special cases. Even though an aneurysm of the superior mesenteric artery is rare, it has to be considered in the differential diagnosis of persisting abdominal problems of unknown origin. This is especially true for patients with a predisposing history such as previous or existing endocarditis, sepsis, arteriosclerosis and hypertension. Because of the possibility of rupture followed by life threating bleeding an adequate diagnostic step such as arteriography has to be considered finally. (orig.) [de

  20. Aneurysmal Subarachnoid Hemorrhage

    Science.gov (United States)

    2015-01-01

    Aneurysmal subarachnoid hemorrhage (SAH) is a worldwide health burden with high fatality and permanent disability rates. The overall prognosis depends on the volume of the initial bleed, rebleeding, and degree of delayed cerebral ischemia (DCI). Cardiac manifestations and neurogenic pulmonary edema indicate the severity of SAH. The International Subarachnoid Aneurysm Trial (ISAT) reported a favorable neurological outcome with the endovascular coiling procedure compared with surgical clipping at the end of 1 year. The ISAT trial recruits were primarily neurologically good grade patients with smaller anterior circulation aneurysms, and therefore the results cannot be reliably extrapolated to larger aneurysms, posterior circulation aneurysms, patients presenting with complex aneurysm morphology, and poor neurological grades. The role of hypothermia is not proven to be neuroprotective according to a large randomized controlled trial, Intraoperative Hypothermia for Aneurysms Surgery Trial (IHAST II), which recruited patients with good neurological grades. Patients in this trial were subjected to slow cooling and inadequate cooling time and were rewarmed rapidly. This methodology would have reduced the beneficial effects of hypothermia. Adenosine is found to be beneficial for transient induced hypotension in 2 retrospective analyses, without increasing the risk for cardiac and neurological morbidity. The neurological benefit of pharmacological neuroprotection and neuromonitoring is not proven in patients undergoing clipping of aneurysms. DCI is an important cause of morbidity and mortality following SAH, and the pathophysiology is likely multifactorial and not yet understood. At present, oral nimodipine has an established role in the management of DCI, along with maintenance of euvolemia and induced hypertension. Following SAH, hypernatremia, although less common than hyponatremia, is a predictor of poor neurological outcome. PMID:25272066

  1. Skin Graft

    OpenAIRE

    Shimizu, Ruka; Kishi, Kazuo

    2012-01-01

    Skin graft is one of the most indispensable techniques in plastic surgery and dermatology. Skin grafts are used in a variety of clinical situations, such as traumatic wounds, defects after oncologic resection, burn reconstruction, scar contracture release, congenital skin deficiencies, hair restoration, vitiligo, and nipple-areola reconstruction. Skin grafts are generally avoided in the management of more complex wounds. Conditions with deep spaces and exposed bones normally require the use o...

  2. Brachial artery aneurysm and thrombosis secondary to fibromuscular dysplasia

    Directory of Open Access Journals (Sweden)

    Julia Louise Jones, MBBS

    2016-09-01

    Full Text Available Fibromuscular dysplasia is a pathologic process causing stenosis and dilation of medium-caliber arteries of unknown etiology. It most commonly affects the renal and carotid arteries; however, it has been described in virtually all anatomic areas, including, rarely, the brachial artery. We describe a case of brachial artery aneurysm and thrombosis in a 29-year-old man secondary to fibromuscular dysplasia, treated surgically with excision, embolectomy, interposed vein graft, and anticoagulation.

  3. Radiation Exposure in Endovascular Infra-Renal Aortic Aneurysm Repair and Factors that Influence It

    Directory of Open Access Journals (Sweden)

    Rui Machado

    Full Text Available Abstract Objective: The endovascular repair of aortic abdominal aneurysms exposes the patients and surgical team to ionizing radiation with risk of direct tissue damage and induction of gene mutation. This study aims to describe our standard of radiation exposure in endovascular aortic aneurysm repair and the factors that influence it. Methods: Retrospective analysis of a prospective database of patients with abdominal infra-renal aortic aneurysms submitted to endovascular repair. This study evaluated the radiation doses (dose area product (DAP, fluoroscopy durations and their relationships to the patients, aneurysms, and stent-graft characteristics. Results: This study included 127 patients with a mean age of 73 years. The mean DAP was 4.8 mGy.m2, and the fluoroscopy time was 21.8 minutes. Aortic bilateral iliac aneurysms, higher body mass index, aneurysms with diameters larger than 60 mm, necks with diameters larger than 28 mm, common iliac arteries with diameters larger than 20 mm, and neck angulations superior to 50 degrees were associated with an increased radiation dose. The number of anatomic risk factors present was associated with increased radiation exposure and fluoroscopy time, regardless of the anatomical risk factors. Conclusion: The radiation exposure during endovascular aortic aneurysm repair is significant (mean DAP 4.8 mGy.m2 with potential hazards to the surgical team and the patients. The anatomical characteristics of the aneurysm, patient characteristics, and the procedure's technical difficulty were all related to increased radiation exposure during endovascular aortic aneurysm repair procedures. Approximately 40% of radiation exposure can be explained by body mass index, neck angulation, aneurysm diameter, neck diameter, and aneurysm type.

  4. Endovascular treatment of very small intracranial aneurysms

    DEFF Research Database (Denmark)

    Iskandar, A; Nepper-Rasmussen, J

    2011-01-01

    to large aneurysms (> 3 mm). However the data also suggest that endovascular treatment of very small aneurysms might be associated with an increased risk of procedural ruptures and mortality. At nine-month follow-up results indicate significantly less compaction in the very small aneurysms....... endovascular treatment was attempted in 956 consecutive intracranial aneurysms. Of 956 aneurysms, 111 aneurysms were very small aneurysms with a maximal diameter of 3 mm or less. We conducted a retrospective analysis of angiographic and clinical outcome following coiling of very small aneurysms...... aneurysms and less than 90% aneurysm occlusion in six aneurysms. Complications occurred in the treatment of 15 aneurysms, including eight procedural ruptures, six thromboembolic events and one case of early hemorrhage. Compared with larger aneurysms, treatment of very small aneurysms was associated...

  5. Blood flow dynamic improvement with aneurysm repair detected by a patient-specific model of multiple aortic aneurysms.

    Science.gov (United States)

    Sughimoto, Koichi; Takahara, Yoshiharu; Mogi, Kenji; Yamazaki, Kenji; Tsubota, Ken'ichi; Liang, Fuyou; Liu, Hao

    2014-05-01

    Aortic aneurysms may cause the turbulence of blood flow and result in the energy loss of the blood flow, while grafting of the dilated aorta may ameliorate these hemodynamic disturbances, contributing to the alleviation of the energy efficiency of blood flow delivery. However, evaluating of the energy efficiency of blood flow in an aortic aneurysm has been technically difficult to estimate and not comprehensively understood yet. We devised a multiscale computational biomechanical model, introducing novel flow indices, to investigate a single male patient with multiple aortic aneurysms. Preoperative levels of wall shear stress and oscillatory shear index (OSI) were elevated but declined after staged grafting procedures: OSI decreased from 0.280 to 0.257 (first operation) and 0.221 (second operation). Graftings may strategically counter the loss of efficient blood delivery to improve hemodynamics of the aorta. The energy efficiency of blood flow also improved postoperatively. Novel indices of pulsatile pressure index (PPI) and pulsatile energy loss index (PELI) were evaluated to characterize and quantify energy loss of pulsatile blood flow. Mean PPI decreased from 0.445 to 0.423 (first operation) and 0.359 (second operation), respectively; while the preoperative PELI of 0.986 dropped to 0.820 and 0.831. Graftings contributed not only to ameliorate wall shear stress or oscillatory shear index but also to improve efficient blood flow. This patient-specific modeling will help in analyzing the mechanism of aortic aneurysm formation and may play an important role in quantifying the energy efficiency or loss in blood delivery.

  6. Development of a New Intravascular Low-Profile Device for Exclusion of Aortic Aneurysm: An Experimental Pilot Study

    International Nuclear Information System (INIS)

    Strecker, Ernst-Peter; Haberstroh, Joerg; Boos, Irene; Metz, Stephan; Langer, Mathias; Moliner, Manuel Maynar

    2004-01-01

    Purpose: To present a new intravascular device for the treatment of aorto-iliac aneurysms. Methods: This new device was tested in five dogs with abdominal aortic aneurysm created experimentally by overdilation of a balloon-expandable stent with a 16 or 18 mm wide PTA balloon catheter. The design of the device is based on a self-expanding aortic stent which consists of two stretchable circular frames filled with a textile Dacron mesh membrane that is suspended horizontally into the infrarenal abdominal aorta proximally to the aneurysm. The frames are part of a preshaped double helical structure that is introduced longitudinally through a catheter in a parallel fashion and forming the desired shape at the vessel site to be occluded. Two iliac stent-grafts are introduced in a low-profile status through the membrane sealing the aneurysm sac and holding the stent-grafts in place. After stent-graft expansion, a new bifurcation located more proximally than the natural one is created. The follow-up of the dogs was performed clinically and angiographically, and specimens were evaluated histomorphologically. Results: The membrane device can be introduced through a 9 Fr vascular sheath. Technical success was achieved in four of five dogs. Nine of ten stent-grafts could be fixed securely within the membrane, thus preventing dislocation. Aneurysms were excluded immediately, and blood flow to the external iliac arteries was restored by the stent-grafts. At 6-9 months follow-up of technically successful implanted devices, there were no endoleaks, no migration, no stenoses at contact sites between the implant material and vascular wall, and no stenosis or occlusion of the stent-grafts. At microscopic evaluation, the interspace between the membranes was filled with thrombotic material, thus ensuring exclusion of the aneurysm. Conclusion: This new device was found to be flexible, low profile and useful in excluding abdominal aortic aneurysm in the experimental setting

  7. Aneurysms in the vertebro-basilary flow region: standard protections (town and lateral projections), BASIS projections, and ispilateral inclined exposures

    International Nuclear Information System (INIS)

    Hering, M.; Zwicker, C.; Wakhloo, A.K.; Schumacher, M.

    1998-01-01

    In spite of procedures such as CT angiography, MR angiography, and rotation angiography, panangiography is still indispensable in therapeutic planning for cerebral aneurysms. It is the only method that provides exact details about the size, anatomic localization, and multiplicity of aneurysms as well as relation to surrounding vessels, the presence of an aneurysmal neck, and for the evaluation of the collateral circulation required to answer the question if endovascular therapy is possible. In addition, panangiography still exhibits the highest selectivity in the detection of cerebral aneurysms. (orig.) [de

  8. Giant true celiac artery aneurysm

    International Nuclear Information System (INIS)

    Aljabri, Badr

    2009-01-01

    Celiac artery aneurysms are rare and usually asymptomatic. The management of these aneurysms is challenging, especially when they are large and involve the confluence of the trifurcation. We present here a case of a large celiac artery aneurysm involving its branches in a young woman. Preoperative investigations, intraoperative findings, and the operative procedure are also presented and discussed. (author

  9. Postoperative subdural hygroma and chronic subdural hematoma after unruptured aneurysm surgery: age, sex, and aneurysm location as independent risk factors.

    Science.gov (United States)

    Park, Jaechan; Cho, Jae-Hoon; Goh, Duck-Ho; Kang, Dong-Hun; Shin, Im Hee; Hamm, In-Suk

    2016-02-01

    This study investigated the incidence and risk factors for the postoperative occurrence of subdural complications, such as a subdural hygroma and resultant chronic subdural hematoma (CSDH), following surgical clipping of an unruptured aneurysm. The critical age affecting such occurrences and follow-up results were also examined. The case series included 364 consecutive patients who underwent aneurysm clipping via a pterional or superciliary keyhole approach for an unruptured saccular aneurysm in the anterior cerebral circulation between 2007 and 2013. The subdural hygromas were identified based on CT scans 6-9 weeks after surgery, and the volumes were measured using volumetry studies. Until their complete resolution, all the subdural hygromas were followed using CT scans every 1-2 months. Meanwhile, the CSDHs were classified as nonoperative or operative lesions that were treated by bur-hole drainage. The age and sex of the patients, aneurysm location, history of a subarachnoid hemorrhage (SAH), and surgical approach (pterional vs superciliary) were all analyzed regarding the postoperative occurrence of a subdural hygroma or CSDH. The follow-up results of the subdural complications were also investigated. Seventy patients (19.2%) developed a subdural hygroma or CSDH. The results of a multivariate analysis showed that advanced age (p = 0.003), male sex (p 60 years, which achieved a 70% sensitivity and 69% specificity with regard to predicting such subdural complications. The female patients ≤ 60 years of age showed a negligible incidence of subdural complications for all aneurysm groups, whereas the male patients > 60 years of age showed the highest incidence of subdural complications at 50%-100%, according to the aneurysm location. The subdural hygromas detected 6-9 weeks postoperatively showed different follow-up results, according to the severity. The subdural hygromas that converted to a CSDH were larger in volume than the subdural hygromas that resolved

  10. Abdominal ultrasound-scanning versus non-contrast computed tomography as screening method for abdominal aortic aneurysm

    DEFF Research Database (Denmark)

    Liisberg, Mads; Diederichsen, Axel C.; Lindholt, Jes S.

    2017-01-01

    Background: Validating non-contrast-enhanced computed tomography (nCT) compared to ultrasound sonography (US) as screening method for abdominal aortic aneurysm (AAA) screening. Methods: Consecutively attending men (n = 566) from the pilot study of the randomized Danish CardioVascular Screening......CT seems superior to US concerning sensitivity, and is able to detect aneurysmal lesions not detectable with US. Finally, the prevalence of AAA in Denmark seems to remain relatively high, in this small pilot study group....

  11. Treatment of splenic artery aneurysm with double overlapping bare stents: case report

    International Nuclear Information System (INIS)

    Kwak, Hyo Sung; Han, Young Min; Jin, Gong Yong

    2004-01-01

    The traditional treatment of splenic artery aneurysm (SAA) is generally surgery and/or transcatheter arterial embolization, but recently, the treatment of SAA using a stent graft has been reported. However, the acute angle of the celiac axis, as well as the tortuous path of the splenic artery makes the use of stent graft difficult for treatment of aneurysma. We report here a case of SAA treated with the technique of double overlapping metallic stents

  12. Dissecting aneurysm of arch and descending thoracic aorta presenting as a left sided hemorrhagic pleural effusion

    Directory of Open Access Journals (Sweden)

    Shamim Shelley

    2010-01-01

    Full Text Available The most common cause of massive hemorrhagic effusion is malignancy. Herein we present a case of dissecting aneurysm of descending thoracic aorta presenting initially with shortness of breath due to left sided massive pleural effusion. Effusion was hemorrhagic in nature with high hematocrit value. CT scan of thorax with CT angiogram was done and that revealed the diagnosis.

  13. Ruptured tuberculous false aneurysm of the abdominal aorta: a case report.

    Science.gov (United States)

    Mechchat, Alae; Lekehal, Brahim; Mesnaoui, Abbes; Ammar, Fannid; Bensaid, Younes

    2011-01-01

    Tuberculous false aneurysm of the aorta is rare and has an unpredictable complication of aneurysm rupture. We report a case of a 32-year old woman who was referred to the Department of Vascular Surgery, Avicenne Hospital for severe abdominal pain. Chest x-ray revealed miliary tuberculosis. Contrast enhanced computed tomography (CT) scan showed a false aortic aneurysm involving the juxtarenal aorta. Antituberculous treatment was started because of high presumption of tuberculosis. Five days later, the patient presented with symptoms of aneurysm rupture. She underwent an emergency a surgical resection of the aneurysm with repair of the aortic wall defect by a Dacron Silver patch. The histopathologic examination of the aortic wall showed features of tuberculosis.

  14. Neurofibromatosis Type 1: Transcatheter Arterial Embolization for Ruptured Occipital Arterial Aneurysms

    International Nuclear Information System (INIS)

    Kanematsu, Masayuki; Kato, Hiroki; Kondo, Hiroshi; Goshima, Satoshi; Tsuge, Yusuke; Kojima, Toshiaki; Watanabe, Haruo

    2011-01-01

    Two cases of ruptured aneurysms in the posterior cervical regions associated with type-1 neurofibromatosis treated by transcatheter embolization are reported. Patients presented with acute onset of swelling and pain in the affected areas. Emergently performed contrast-enhanced CT demonstrated aneurysms and large hematomas widespread in the posterior cervical regions. Angiography revealed aneurysms and extravasations of the occipital artery. Patients were successfully treated by percutaneous transcatheter arterial microcoil embolization. Transcatheter arterial embolization therapy was found to be an effective method for treating aneurysmal rupture in the posterior cervical regions occurring in association with type-1 neurofibromatosis. A literature review revealed that rupture of an occipital arterial aneurysm, in the setting of neurofibromatosis type 1, has not been reported previously.

  15. Two-dimensional echocardiographic and RI angiographic features of aneurysm of the ascending aorta in patients with annuloaortic ectasia

    International Nuclear Information System (INIS)

    Nakamura, Kenji; Suzuki, Shin; Satomi, Gengi

    1981-01-01

    The purpose of this study was to compare the diagnostic value of two-dimensional echocardiography with that of other methods in the detection and localization of aneurysm involving the ascending aorta in patients with annuloaortic ectasia. Two-dimensional echocardiography, RI angiography, CT scan and aortography were performed in 19 patients (12 patients with Marfan's syndrome, 4 with aortitis syndrome and 3 with postoperative perivalvular aneurysm). Eight of 12 patients with Marfan's syndrome had dissection in the ascending aorta which was confirmed at surgery or autopsy. The following observations were obtained. 1) Dissection of the ascending aorta was clearly demonstrated on the two-dimensional echocardiogram in 7 patients by recording the intinal tear and flap, and in these cases the short axis two-dimensional echocardiogram of the ascending aorta was more useful in identifying the site and extent of dissection. 2) In patients with postoperative perivalvular aneurysms, RI angiography proved to be a more useful and sensitive technique in differentiating a leakage into the aneurysm from clots in the aneurysm. 3) CT scanning proved to be an insensitive technique to detect dissection of the ascending aneurysm and to differentiate a leakage from clots in the perivalvular aneurysm. From these observations, we concluded that two-dimensional echocardiography and RI angiography proved to be sensitive techniques in detecting dissection of the ascending aneurysm and evaluating a postoperative aneurysm in patients with annuloaortic ectasia. (author)

  16. Two-dimensional echocardiographic and RI angiographic features of aneurysm of the ascending aorta in patients with annuloaortic ectasia

    Energy Technology Data Exchange (ETDEWEB)

    Nakamura, K.; Suzuki, S.; Satomi, G. (Tokyo Women' s Medical Coll. (Japan). Heart Inst. and Hospital)

    1981-03-01

    The purpose of this study was to compare the diagnostic value of two-dimensional echocardiography with that of other methods in the detection and localization of aneurysm involving the ascending aorta in patients with annuloaortic ectasia. Two-dimensional echocardiography, RI angiography, CT scan and aortography were performed in 19 patients (12 patients with Marfan's syndrome, 4 with aortitis syndrome and 3 with postoperative perivalvular aneurysm). Eight of 12 patients with Marfan's syndrome had dissection in the ascending aorta which was confirmed at surgery or autopsy. The following observations were obtained. 1) Dissection of the ascending aorta was clearly demonstrated on the two-dimensional echocardiogram in 7 patients by recording the intinal tear and flap, and in these cases the short axis two-dimensional echocardiogram of the ascending aorta was more useful in identifying the site and extent of dissection. 2) In patients with postoperative perivalvular aneurysms, RI angiography proved to be a more useful and sensitive technique in differentiating a leakage into the aneurysm from clots in the aneurysm. 3) CT scanning proved to be an insensitive technique to detect dissection of the ascending aneurysm and to differentiate a leakage from clots in the perivalvular aneurysm. From these observations, we concluded that two-dimensional echocardiography and RI angiography proved to be sensitive techniques in detecting dissection of the ascending aneurysm and evaluating a postoperative aneurysm in patients with annuloaortic ectasia.

  17. Establishment of a new murine elastase-induced aneurysm model combined with transplantation.

    Directory of Open Access Journals (Sweden)

    Zuzanna Rowinska

    Full Text Available The aim of our study was to develop a reproducible murine model of elastase-induced aneurysm formation combined with aortic transplantation.Adult male mice (n = 6-9 per group underwent infrarenal, orthotopic transplantation of the aorta treated with elastase or left untreated. Subsequently, both groups of mice were monitored by ultrasound until 7 weeks after grafting.Mice receiving an elastase-pretreated aorta developed aneurysms and exhibited a significantly increased diastolic vessel diameter compared to control grafted mice at 7 week after surgery (1.11 ± 0.10 mm vs. 0.75 ± 0.03 mm; p ≤ 0,001. Histopathological examination revealed disruption of medial elastin, an increase in collagen content and smooth muscle cells, and neointima formation in aneurysm grafts.We developed a reproducible murine model of elastase-induced aneurysm combined with aortic transplantation. This model may be suitable to investigate aneurysm-specific inflammatory processes and for use in gene-targeted animals.

  18. Aneurysmal bone cyst of the temporal bone

    International Nuclear Information System (INIS)

    Buxi, Tarvinder; Sud Seema; Vohra, Rakesh; Sud, Aditi; Singh, Satnam

    2004-01-01

    Aneurysmal bone cyst (ABC) of the temporal bone is rare. The nature of the underlying disorder that converted into the ABC might, however, be difficult to ascertain on imaging as well as on histopathology. The unusual CT and MRI findings in a case of ABC of the temporal bone are presented. This had transdural intracerebral spread with a large component of solid enhancing matrix but no peripheral calcific rim. The patient was an adult of 45 years with a history of headache for more than 1 year Copyright (2004) Blackwell Publishing Asia Pty Ltd

  19. Endovascular repair of abdominal aortic aneurysms: vascular anatomy, device selection, procedure, and procedure-specific complications.

    Science.gov (United States)

    Bryce, Yolanda; Rogoff, Philip; Romanelli, Donald; Reichle, Ralph

    2015-01-01

    Abdominal aortic aneurysm (AAA) is abnormal dilatation of the aorta, carrying a substantial risk of rupture and thereby marked risk of death. Open repair of AAA involves lengthy surgery time, anesthesia, and substantial recovery time. Endovascular aneurysm repair (EVAR) provides a safer option for patients with advanced age and pulmonary, cardiac, and renal dysfunction. Successful endovascular repair of AAA depends on correct selection of patients (on the basis of their vascular anatomy), choice of the correct endoprosthesis, and familiarity with the technique and procedure-specific complications. The type of aneurysm is defined by its location with respect to the renal arteries, whether it is a true or false aneurysm, and whether the common iliac arteries are involved. Vascular anatomy can be divided more technically into aortic neck, aortic aneurysm, pelvic perfusion, and iliac morphology, with grades of difficulty with respect to EVAR, aortic neck morphology being the most common factor to affect EVAR appropriateness. When choosing among the devices available on the market, one must consider the patient's vascular anatomy and choose between devices that provide suprarenal fixation versus those that provide infrarenal fixation. A successful technique can be divided into preprocedural imaging, ancillary procedures before AAA stent-graft placement, the procedure itself, postprocedural medical therapy, and postprocedural imaging surveillance. Imaging surveillance is important in assessing complications such as limb thrombosis, endoleaks, graft migration, enlargement of the aneurysm sac, and rupture. Last, one must consider the issue of radiation safety with regard to EVAR. (©)RSNA, 2015.

  20. PCA-induced respiratory depression simulating stroke following endoluminal repair of abdominal aortic aneurysm: a case report

    Directory of Open Access Journals (Sweden)

    Ahmad Javed

    2007-07-01

    Full Text Available Abstract Aim To report a case of severe respiratory depression with PCA fentanyl use simulating stroke in a patient who underwent routine elective endoluminal graft repair for abdominal aortic aneurysm (AAA Case presentation A 78-year-old obese lady underwent routine endoluminal graft repair for AAA that was progressively increasing in size. Following an uneventful operation postoperative analgesia was managed with a patient-controlled analgesia (PCA device with fentanyl. On the morning following operation the patient was found to be unusually drowsy and unresponsive to stimuli. Her GCS level was 11 with plantars upgoing bilaterally. A provisional diagnosis of stroke was made. Urgent transfer to a high-dependency unit (HDU was arranged and she was given ventilatory support with a BiPap device. CT was performed and found to be normal. Arterial blood gas (ABG analysis showed respiratory acidosis with PaCO2 81 mmHg, PaO2 140 mmHg, pH 7.17 and base excess -2 mmol/l. A total dose of 600 mcg of fentanyl was self-administered in the 16 hours following emergence from general anaesthesia. Naloxone was given with good effect. There was an increase in the creatinine level from 90 μmol/L preoperatively to 167 μmol/L on the first postoperative day. The patient remained on BiPap for two days that resulted in marked improvement in gas exchange. Recovery was complete.

  1. Pancreas grafts

    International Nuclear Information System (INIS)

    Hahn, D.; Buell, U.; Land, W.; Unertl, K.

    1981-01-01

    Perfusion studies with sup(99m)Tc-DTPA, which has hitherto been used routinely to investigate renal grafts, have also proved useful for monitoring the perfusion of pancreas grafts. A total perfusion failure is equally reliably demonstrable as in renal grafts. Quantitatively smaller perfusion alterations can be demonstrated by monitoring the course. It seems possible to differentiate the salivary edema of a rejection reaction, well known from animal experiments, with the help of other paramters (e.g. creatinine). Further clinical studies are however necessary to confirm these results. (orig.) [de

  2. Extraosseous aneurysmal cyst in hand: a case report.

    Science.gov (United States)

    Sahu, Ajay; Gujral, Sarabjeet S; Gaur, Sanjeev

    2008-10-24

    The presence of primary aneurysmal cyst in soft tissues is a extremely rare and its presence in the soft tissues of hand has never been reported in literature before. We report the first ever case of extraosseous aneurysmal cyst in hand. A twelve years old girl presented with a swelling in the thenar region on palmer aspect of right hand growing slowly since three months. On X ray, CT scan and excision biopsy the lesion was found to be separate from bone and located in the soft tissue. Its diagnosis was confirmed on histopatholgical examination. Previously few authors have reported extraosseous aneurysmal cyst in the soft tissues of shoulder, hip and pelvic girdle but nobody has reported its presence in the soft tissues of hand.

  3. Acute Contained Ruptured Aortic Aneurysm Presenting as Left Vocal Fold Immobility

    OpenAIRE

    Gnagi, Sharon H.; Howard, Brittany E.; Hoxworth, Joseph M.; Lott, David G.

    2015-01-01

    Objective. To recognize intrathoracic abnormalities, including expansion or rupture of aortic aneurysms, as a source of acute onset vocal fold immobility. Methods. A case report and review of the literature. Results. An 85-year-old female with prior history of an aortic aneurysm presented to a tertiary care facility with sudden onset hoarseness. On laryngoscopy, the left vocal fold was immobile in the paramedian position. A CT scan obtained that day revealed a new, large hematoma surrounding ...

  4. Transcatheter Embolization of Pulmonary Artery False Aneurysm Associated with Primary Pulmonary Hypertension

    International Nuclear Information System (INIS)

    Hiraki, T.; Kanazawa, S.; Mimura, H.; Yasui, K.; Okumura, Y.; Dendo, S.; Yoshimura, K.; Takahara, M.; Hiraki, Y.

    2004-01-01

    A 29-year-old woman with primary pulmonary hypertension presented with recurrent hemoptysis. Contrast-enhanced CT of the chest demonstrated the enhanced mass surrounded by consolidation related to parenchymal hemorrhage. Pulmonary angiography suggested that the mass was a pulmonary artery false aneurysm. After a microcatheter was superselectively inserted into the parent artery of the falseaneurysm, the false aneurysm was successfully treated by transcatheterembolization with coils. Her hemoptysis has never recurred

  5. Spontaneous intracranial hemorrhage and multiple intracranial aneurysms in a patient with Roberts/SC phocomelia syndrome.

    Science.gov (United States)

    Wang, Anthony C; Gemmete, Joseph J; Keegan, Catherine E; Witt, Cordelie E; Muraszko, Karin M; Than, Khoi D; Maher, Cormac O

    2011-11-01

    Roberts/SC phocomelia syndrome (RBS) is a rare but distinct genetic disorder with an autosomal recessive inheritance pattern. It has been associated with microcephaly, craniofacial malformation, cavernous hemangioma, encephalocele, and hydrocephalus. There are no previously reported cases of RBS with intracranial aneurysms. The authors report on a patient with a history of RBS who presented with a spontaneous posterior fossa hemorrhage. Multiple small intracranial aneurysms were noted on a preoperative CT angiogram. The patient underwent emergency craniotomy for evacuation of the hemorrhage. A postoperative angiogram confirmed the presence of multiple, distal small intracranial aneurysms.

  6. Delayed Presentation of a Giant Ascending Aortic Aneurysm following Aortic Valve Replacement

    Directory of Open Access Journals (Sweden)

    Tugrul Göncü

    2009-01-01

    Full Text Available Giant ascending aortic aneurysm formation following aortic valve replacement is rare. A 28-year-old man who underwent aortic valve replacement with a prosthetic valve for aortic regurgitation secondary to congenital bicuspid aortic valve about 10 years ago was diagnosed with a giant ascending aortic aneurysm about 16 cm in diameter in follow-up. The aneurysm was resected leaving the functional old mechanical prosthesis in place and implanted a 34-mm Hemashield woven graft, associated with the left and right coronary artery button implantation. Histological findings of the aortic aneurysm wall showed cystic medial necrosis. The postoperative course was uneventful and postoperative examination demonstrated good surgical results.

  7. Mixed reality for robotic treatment of a splenic artery aneurysm.

    Science.gov (United States)

    Pietrabissa, Andrea; Morelli, Luca; Ferrari, Mauro; Peri, Andrea; Ferrari, Vincenzo; Moglia, Andrea; Pugliese, Luigi; Guarracino, Fabio; Mosca, Franco

    2010-05-01

    Techniques of mixed reality can successfully be used in preoperative planning of laparoscopic and robotic procedures and to guide surgical dissection and enhance its accuracy. A computer-generated three-dimensional (3D) model of the vascular anatomy of the spleen was obtained from the computed tomography (CT) dataset of a patient with a 3-cm splenic artery aneurysm. Using an environmental infrared localizer and a stereoscopic helmet, the surgeon can see the patient's anatomy in transparency (augmented or mixed reality). This arrangement simplifies correct positioning of trocars and locates surgical dissection directly on top of the aneurysm. In this way the surgeon limits unnecessary dissection, leaving intact the blood supply from the short gastric vessels and other collaterals. Based on preoperative planning, we were able to anticipate that the vascular exclusion of the aneurysm would result in partial splenic ischemia. To re-establish the flow to the spleen, end-to-end robotic anastomosis of the splenic artery with the Da Vinci surgical system was then performed. Finally, the aneurysm was fenestrated to exclude arterial refilling. The postoperative course was uneventful. A control CT scan 4 weeks after surgery showed a well-perfused and homogeneous splenic parenchyma. The final 3D model showed the fenestrated calcified aneurysm and patency of the re-anastomosed splenic artery. The described technique of robotic vascular exclusion of a splenic artery aneurysm, followed by re-anastomosis of the vessel, clearly demonstrates how this technology can reduce the invasiveness of the procedure, obviating an otherwise necessary splenectomy. Also, the use of intraoperative mixed-reality technology proved very useful in this case and is expected to play an increasing role in the operating room of the future.

  8. Cadaveric aorta implantation for aortic graft infection.

    Science.gov (United States)

    Ali, Asad; Bahia, Sandeep S S; Ali, Tahir

    2016-01-01

    This case report describes a 73-year-old gentleman who underwent explantation of an infected prosthetic aorto-iliac graft and replacement with a cryopreserved thoracic and aorto-iliac allograft. The patient has been followed up a for more than a year after surgery and remains well. After elective tube graft repair of his abdominal aortic aneurysm (AAA) in 2003, he presented to our unit in 2012 in cardiac arrest as a result of a rupture of the distal graft suture line due to infection. After resuscitation he underwent aorto-bifemoral grafting using a cuff of the original aortic graft proximally. Distally the new graft was anastomosed to his common femoral arteries, with gentamicin beads left in situ. Post discharge the patient was kept under close surveillance with serial investigations including nuclear scanning, however it became apparent that his new graft was infected and that he would require aortic graft replacement, an operation with a mortality of at least 50%. The patient underwent the operation and findings confirmed a synthetic graft infection. This tube graft was explanted and a cryopreserved aorta was used to the refashion the abdominal aorta and its bifurcation. The operation required a return to theatre day one post operatively for a bleeding side branch, which was repaired. The patient went on to make a full recovery stepping down from the intensive therapy unit day 6 post operatively and went on to be discharged 32 days after his cryopreserved aorta implantation. Copyright © 2016 The Author(s). Published by Elsevier Ltd.. All rights reserved.

  9. Early experience with the multilayer aneurysm repair stent in the endovascular treatment of trans/infragenicular popliteal artery aneurysms: a mixed bag.

    Science.gov (United States)

    Thakar, Tejal; Chaudhuri, Arindam

    2013-06-01

    To present a preliminary experience using a multilayer flow-modulating stent for trans/infragenicular popliteal endovascular aneurysm repair. Five men (mean age 76 years, range 62-86) with 6 popliteal artery aneurysms (PAAs) measuring 22 to 39 mm in diameter (mean 30) underwent endovascular repair using the Cardiatis Multilayer Aneurysm Repair System (MARS) between June and August 2011. Radiological assessments post procedure using duplex ultrasonography and biplanar knee radiographs (additional contrast studies as necessary) sought evidence of aneurysm exclusion, graft patency, and preservation of branches and runoff vessels. Technical success was achieved in each case. There was one symptomatic stent occlusion requiring thrombectomy at 4 days, with reocclusion, and one leak via the stent struts into the sac with no branch outflow identified. Two further symptomatic stent occlusions were identified within a 6-week follow-up period, totaling 3 occlusions among the 6 devices deployed. No firm conclusion can be reached on the efficacy of the MARS in PAAs due to the inherent limitations of this small series, although a 50% thrombosis rate is a poor outcome. The risk of early thrombosis in flow-modulating stents deployed in the popliteal artery exists, as it does with earlier generation stent-grafts. Larger prospective trials and the influence of more aggressive antithrombotic/anticoagulant therapy should be considered to enable accurate evaluation of this device in popliteal artery aneurysms.

  10. Splenic artery aneurysm: a diagnostic challenge in the setting of extensive portal venous collaterals

    Energy Technology Data Exchange (ETDEWEB)

    Phillips, Grace S.; Vo, Nghia J.; Ishak, Gisele E.; Swanson, Jonathan O.; Otto, Randolph K. [University of Washington, Seattle Children' s Hospital, Department of Radiology, Seattle, WA (United States)

    2010-07-15

    We present a 16-year-old boy with autoimmune liver disease and longstanding portal hypertension in whom a CT arteriogram demonstrated a large aneurysm arising from the distal, extra-parenchymal portion of the splenic artery. Because of its location adjacent to multiple venous collaterals, the aneurysm was indistinguishable from splenic varices on initial imaging with Doppler sonography and on portal venous-phase CT. There is an increased risk of rupture of splenic artery aneurysms in the post-liver transplant period, with high associated mortality, and therefore diagnosis of splenic artery aneurysm prior to liver transplantation is clinically important. It is quite possible that the diagnosis of splenic artery aneurysm in this case would have been missed in the absence of dedicated arterial-phase imaging. As radiologists strive to reduce radiation exposure in children, this case highlights a potential diagnostic pitfall of both Doppler sonography and venous or single-acquisition arterial/venous-phase CT angiogram in children with venous collaterals and an undiagnosed splenic artery aneurysm. (orig.)

  11. Splenic artery aneurysm: a diagnostic challenge in the setting of extensive portal venous collaterals

    International Nuclear Information System (INIS)

    Phillips, Grace S.; Vo, Nghia J.; Ishak, Gisele E.; Swanson, Jonathan O.; Otto, Randolph K.

    2010-01-01

    We present a 16-year-old boy with autoimmune liver disease and longstanding portal hypertension in whom a CT arteriogram demonstrated a large aneurysm arising from the distal, extra-parenchymal portion of the splenic artery. Because of its location adjacent to multiple venous collaterals, the aneurysm was indistinguishable from splenic varices on initial imaging with Doppler sonography and on portal venous-phase CT. There is an increased risk of rupture of splenic artery aneurysms in the post-liver transplant period, with high associated mortality, and therefore diagnosis of splenic artery aneurysm prior to liver transplantation is clinically important. It is quite possible that the diagnosis of splenic artery aneurysm in this case would have been missed in the absence of dedicated arterial-phase imaging. As radiologists strive to reduce radiation exposure in children, this case highlights a potential diagnostic pitfall of both Doppler sonography and venous or single-acquisition arterial/venous-phase CT angiogram in children with venous collaterals and an undiagnosed splenic artery aneurysm. (orig.)

  12. Dissecting aneurysm of the cervical internal carotid artery

    International Nuclear Information System (INIS)

    Itoh, Yoshihiro; Itoyama, Youichi; Fukumura, Akinobu; Matsukado, Yasuhiko; Kodama, Takafumi.

    1987-01-01

    On lifting a heavy case, a 51-year-old male experienced a sudden onset of headache with giddiness and clouded vision. A week later, vertigo and right hand numbness were added to his symptoms. The next day anisocoria (right > left) and dilation of the left retinal veins were noted. Cranial computed tomography (CT) scan appeared normal and there were no other remarkable neurological findings. The patient was treated conservatively for cerebral infarction, however, the headache worsened and diplopia occurred. Neurological examination on admission revealed nothing unusual except for left Horner's syndrome. Physical examination showed a palpable sausage-like painless tumor on the left side of the neck. Angiography showed a narrowing of the internal carotid artery in the cervical region with a small dissecting aneurysm at the C3 level. Cervical CT scan at the upper C3 level showed a low density lunar defect in the high density section of the enlarged left internal carotid artery. The patient was operated on by superficial temporal artery-middle cerebral artery anastomosis to increase the intracranial blood flow. Postoperatively the symptoms were quickly relieved. Angiography 1 month later showed less narrowing of the carotid artery, though the dissecting aneurysm still remained. Postoperative cervical CT scan showed the left internal carotid artery to be of normal size. The patient returned to his work in normal condition 2 months later. It is emphasized that cervical CT scan may be useful in the diagnosis of this unusual type of cervical dissecting aneurysm. (author)

  13. Noninvasive radiodiagnosis of aneurysms of the thoracic aorta

    International Nuclear Information System (INIS)

    Todua, F.I.; Petsko, A.P.; Arablinskij, A.V.; Kazanchyan, P.O.; Nikitaev, N.S.; Sultanaliev, T.A.

    1990-01-01

    The paper is concerned with analysis of the results of X-ray investigation of 45 patients with aneurysms of the distal part of the arch and descending part of the thoracic aorta. X-ray investigation helped to establish correct diagnosis of aneurysm of the aorta in 42 of 45 patients (93.3 %) on the basis of the detection of intense additional shadow formation in left pulmonary field, unseparable from the aortic shadow. The use of a new method of ultrasound diagnosis-duplex scanning-made it possible to establish the presence of aneurysm and to determine its sizes as well as to visualize the relation of the left subclavicular artery to aneurysm in 17 of 21 patients. CT-semiotics of aneurysms of the descending part of the thoracic aorta consisted in its dilatation over 3.5 cm, wall calcification, thrombosis of the cavity and change of the adjacent structures. Basing on the analysis of these signs correct diagnosis was established in 34 of 35 examinees (97.1 %)

  14. Endovascular treatment of splenic artery aneurysms

    International Nuclear Information System (INIS)

    Lagana, Domenico; Carrafiello, Gianpaolo; Mangini, Monica; Fontana, Federico; Dizonno, Massimiliano; Fugazzola, Carlo; Castelli, Patrizio

    2005-01-01

    Purpose. To assess the feasibility and effectiveness of endovascular treatment of splenic artery aneurysm (SAAs). Materials and methods. Between May 2000 and June 2003 we treated 11 true SAAs in 9 patients (7 females and 2 males; mean age 58 years), 8 saccular and 3 fusiform, 4 located at the middle tract of the splenic artery, 5 at the distal tract and 2 intra-parenchymal. The diagnosis was performed with colour-Doppler ultrasound and/or CT-angiography; 7 patients were symptomless, 1 had left hypochondriac pain, and 1 had acute abdomen caused by a ruptured SAA. Four SAAs were treated by micro coil embolisation of the aneurysmal sac with preservation of splenic artery patency; in 2 cases this was associated with transcatheter injection of N-butyl-2-cyanoacrylate. Four cases were treated by endovascular ligature, with sectoral spleen ischaemia. One ruptured SAA received emergency treatment with splenic artery cyanoacrylate embolisation. Two intra-parenchymal SAAs were excluded, one by cyanoacrylate embolisation of the afferent artery and the other by transcatheter thrombin injection in the aneurysmal sac. Results. Technical success was observed in all cases (in 10/11 at the end of the procedure; in 1/11 at CT performed 3 days after the procedure). The follow-up (mean 18 months; range 6-36) was performed by colour-Doppler ultrasound and/or CT-angiography 3, 6 and 12 months after the procedure and subsequently once a year; the complete exclusion of the aneurysms was confirmed in 11/11 cases. The complications were: 4 cases of mild pleuritis; fever and left hypochondriac pain 1 day after the procedure (in the same 4 patients and in one other case); 5 cases of sectorial spleen ischaemia and 1 case of diffuse spleen infarction with partial revascularization by collateral vessels. No alteration of the levels of pancreatic enzymes was found; a transitory increase in platelet count occurred only in the patient with diffuse spleen infarction. Conclusions. Using different

  15. Pulmonary artery aneurysm

    African Journals Online (AJOL)

    Enrique

    Introduction. Pulmonary artery aneurysms are a rare finding in general radiological practice. The possible causes are myriad and diverse in pathophysiolo- gy. Patients with post-stenotic dilata- tion of the main pulmonary artery usually present fairly late with insidi- ous cardiorespiratory symptoms. Diagnosis requires ...

  16. Brain Aneurysm: Recovery

    Science.gov (United States)

    ... people, but they are growing larger as medical technology continues to grow and early detection and treatment becomes more prevalent. Read More “I’ve met many people through The Brain Aneurysm Foundation. Each one with their own unique story. Of survival, of appreciation for what we still ...

  17. Duplex ultrasound and computed tomography angiography in the follow-up of endovascular abdominal aortic aneurysm repair: a comparative study

    International Nuclear Information System (INIS)

    Cantador, Alex Aparecido; Siqueira, Daniel Emilio Dalledone; Jacobsen, Octavio Barcellos; Baracat, Jamal; Pereira, Ines Minniti Rodrigues; Menezes, Fabio Hüsemann; Guillaumon, Ana Terezinha

    2016-01-01

    Objective: To compare duplex ultrasound and computed tomography (CT) angiography in terms of their performance in detecting endoleaks, as well as in determining the diameter of the aneurysm sac, in the postoperative follow-up of endovascular abdominal aortic aneurysm repair. Materials and Methods: This was a prospective study involving 30 patients who had undergone endovascular repair of infrarenal aortoiliac aneurysms. Duplex ultrasound and CT angiography were performed simultaneously by independent radiologists. Measurements of the aneurysm sac diameter were assessed, and the presence or absence of endoleaks was determined. Results: The average diameter of the aneurysm sac, as determined by duplex ultrasound and CT angiography was 6.09 ± 1.95 and 6.27 ± 2.16 cm, respectively. Pearson's correlation coefficient showing a statistically significant correlation (R = 0.88; p < 0.01). Comparing the duplex ultrasound and CT angiography results regarding the detection of endoleaks, we found that the former had a negative predictive value of 92.59% and a specificity of 96.15%. Conclusion: Our results show that there is little variation between the two methods evaluated, and that the choice between the two would have no significant effect on clinical management. Duplex ultrasound could replace CT angiography in the postoperative follow-up of endovascular aneurysm repair of the infrarenal aorta, because it is a low-cost procedure without the potential clinical complications related to the use of iodinated contrast and exposure to radiation. (author)

  18. Duplex ultrasound and computed tomography angiography in the follow-up of endovascular abdominal aortic aneurysm repair: a comparative study

    Energy Technology Data Exchange (ETDEWEB)

    Cantador, Alex Aparecido; Siqueira, Daniel Emilio Dalledone; Jacobsen, Octavio Barcellos; Baracat, Jamal; Pereira, Ines Minniti Rodrigues; Menezes, Fabio Hüsemann; Guillaumon, Ana Terezinha, E-mail: alex_cantador@yahoo.com.br [Universidade Estadual de Campinas (FCM/UNICAMP), Campinas, SP (Brazil). Faculdade de Ciencias Medicas

    2016-07-15

    Objective: To compare duplex ultrasound and computed tomography (CT) angiography in terms of their performance in detecting endoleaks, as well as in determining the diameter of the aneurysm sac, in the postoperative follow-up of endovascular abdominal aortic aneurysm repair. Materials and Methods: This was a prospective study involving 30 patients who had undergone endovascular repair of infrarenal aortoiliac aneurysms. Duplex ultrasound and CT angiography were performed simultaneously by independent radiologists. Measurements of the aneurysm sac diameter were assessed, and the presence or absence of endoleaks was determined. Results: The average diameter of the aneurysm sac, as determined by duplex ultrasound and CT angiography was 6.09 ± 1.95 and 6.27 ± 2.16 cm, respectively. Pearson's correlation coefficient showing a statistically significant correlation (R = 0.88; p < 0.01). Comparing the duplex ultrasound and CT angiography results regarding the detection of endoleaks, we found that the former had a negative predictive value of 92.59% and a specificity of 96.15%. Conclusion: Our results show that there is little variation between the two methods evaluated, and that the choice between the two would have no significant effect on clinical management. Duplex ultrasound could replace CT angiography in the postoperative follow-up of endovascular aneurysm repair of the infrarenal aorta, because it is a low-cost procedure without the potential clinical complications related to the use of iodinated contrast and exposure to radiation. (author)

  19. Chronic Contained Rupture of an Abdominal Aortic Aneurysm: From Diagnosis to Endovascular Resolution

    International Nuclear Information System (INIS)

    Gandini, Roberto; Chiocchi, Marcello; Maresca, Luciano; Pipitone, Vincenzo; Messina, Massimo; Simonetti, Giovanni

    2008-01-01

    A male patient, 69 years old, presented with fever, leucocytosis, and persistent low back pain; he also had an abdominal aortic aneurysm (AAA), as previously diagnosed by Doppler UltraSound (US), and was admitted to our hospital. On multislice computed tomography (msCT), a large abdominal mass having no definite border and involving the aorta and both of the psoas muscles was seen. This mass involved the forth-lumbar vertebra with lysis, thus simulating AAA rupture into a paraspinal collection; it was initially considered a paraspinal abscess. After magnetic resonance imaging examination and culture of the fluid aspirated from the mass, no infective organisms were found; therefore, a diagnosisof chronically contained AAA rupture was made, and an aortic endoprosthesis was subsequently implanted. The patient was discharged with decreased lumbar pain. At 12-month follow-up, no evidence of leakage was observed. To our knowledge, this is the first case of endoprosthesis implantation in a patient, who was a poor candidate for surgical intervention due to renal failure, leucocytosis and high fever, having a chronically contained AAA ruptured simulatingspodilodiscitis abscess. Appropriate diagnosis and therapy resolved potentially crippling pathology and avoided surgical graft-related complications.

  20. Embolization of Isolated Hypogastric Artery Aneurysm: A Case Report and a Review of the Literature

    International Nuclear Information System (INIS)

    Medici, Lorenzo de; Bucci, Federico; Nesi, Fabrizio; Rabitti, Giorgio

    2006-01-01

    A 75-year-old man with arterial hypertension, coronary artery disease, and myocardial infarction was referred to our service because of an asymptomatic hypogastric artery aneurysm (HAA) detected by a routine compued tomography (CT) scan. As shown on the angio-CT the maximum transverse diameter (m.t.d.) of the HAA was 47 mm. There were no symptoms of distal embolization or compression on the pelvic structures. We performed the successful complete thrombosis of the aneurysm using vascular plugs via a controlateral femoral approach. The control angiogram was satisfactory and there were no intraoperative complications. A CT-angiography done 4 months after the procedure showed no signs of refilling of the aneurysm sac. This case illustrates some possible advantages of vascular plugs in the treatment of isolated HAA

  1. Epidemiology and contemporary management of abdominal aortic aneurysms.

    Science.gov (United States)

    Ullery, Brant W; Hallett, Richard L; Fleischmann, Dominik

    2018-05-01

    Abdominal aortic aneurysm (AAA) is most commonly defined as a maximal diameter of the abdominal aorta in excess of 3 cm in either anterior-posterior or transverse planes or, alternatively, as a focal dilation ≥ 1.5 times the diameter of the normal adjacent arterial segment. Risk factors for the development of AAA include age > 60, tobacco use, male gender, Caucasian race, and family history of AAA. Aneurysm growth and rupture risk appear to be associated with persistent tobacco use, female gender, and chronic pulmonary disease. The majority of AAAs are asymptomatic and detected incidentally on various imaging studies, including abdominal ultrasound, and computed tomographic angiography. Symptoms associated with AAA may include abdominal or back pain, thromboembolization, atheroembolization, aortic rupture, or development of an arteriovenous or aortoenteric fistula. The Screening Abdominal Aortic Aneurysms Efficiently (SAAAVE) Act provides coverage for a one-time screening abdominal ultrasound at age 65 for men who have smoked at least 100 cigarettes and women who have family history of AAA disease. Medical management is recommended for asymptomatic patients with AAAs  5 mm/6 months), or presence of a fusiform aneurysm with maximum diameter of 5.5 cm or greater. Intervention for AAA includes conventional open surgical repair and endovascular aortic stent graft repair.

  2. Value of computed tomography for the diagnosis and pre and post-treatment workup of aortic aneurysms. Comparison with angiographic findings. A report of data in 112 cases

    International Nuclear Information System (INIS)

    Senac, J.P.; Giron, J.; Ovchinnikoff, S.; Mourre, P.; Joffre, P.; Mary, H.; Novati, J.P.

    1987-01-01

    The authors report that CT scan provided decisive or complementary data, as compared to angiography, in 112 cases of aortic aneurysm. CT scan thus emerges as a useful tool. The inadequate angiographies were either nearly normal, or showed evidence that pointed to total arterial occlusion whose thrombotic and aneurysmal nature was demonstrated only upon computed tomography; CT scan proved irreplaceable for evaluating prostheses and postoperative complications. The axial transverse plane of CT sections explains why computed tomography is so informative: the channel, thrombosis, wall and peri-adventicia (fibrosis, fissuration) are visible successively from the center to the periphery. In the authors' opinion, the pretreatment evaluation of an aortic aneurysm should include a CT angioscan in addition to an angiography as the two procedures complement one another. After surgery, CT scan is even more widely indicated. CT scan is the primary procedure for controlling a prosthesis and often makes other investigations unnecessary [fr

  3. Cardiac CT

    International Nuclear Information System (INIS)

    Dewey, Marc

    2011-01-01

    Computed tomography of the heart has become a highly accurate diagnostic modality that is attracting increasing attention. This extensively illustrated book aims to assist the reader in integrating cardiac CT into daily clinical practice, while also reviewing its current technical status and applications. Clear guidance is provided on the performance and interpretation of imaging using the latest technology, which offers greater coverage, better spatial resolution, and faster imaging. The specific features of scanners from all four main vendors, including those that have only recently become available, are presented. Among the wide range of applications and issues to be discussed are coronary artery bypass grafts, stents, plaques, and anomalies, cardiac valves, congenital and acquired heart disease, and radiation exposure. Upcoming clinical uses of cardiac CT, such as plaque imaging and functional assessment, are also explored. (orig.)

  4. Cardiac CT

    Energy Technology Data Exchange (ETDEWEB)

    Dewey, Marc [Charite - Universitaetsmedizin Berlin (Germany). Inst. fuer Radiologie

    2011-07-01

    Computed tomography of the heart has become a highly accurate diagnostic modality that is attracting increasing attention. This extensively illustrated book aims to assist the reader in integrating cardiac CT into daily clinical practice, while also reviewing its current technical status and applications. Clear guidance is provided on the performance and interpretation of imaging using the latest technology, which offers greater coverage, better spatial resolution, and faster imaging. The specific features of scanners from all four main vendors, including those that have only recently become available, are presented. Among the wide range of applications and issues to be discussed are coronary artery bypass grafts, stents, plaques, and anomalies, cardiac valves, congenital and acquired heart disease, and radiation exposure. Upcoming clinical uses of cardiac CT, such as plaque imaging and functional assessment, are also explored. (orig.)

  5. Aneurysmal coronary artery disease: An overview

    Science.gov (United States)

    ElGuindy, Mohamed S.

    Aneurysmal coronary artery disease (ACAD) comprises both coronary artery aneurysms (CAA) and coronary artery ectasia (CAE). The reported prevalence of ACAD varies widely from 0.2 to 10%, with male predominance and a predilection for the right coronary artery (RCA). Atherosclerosis is the commonest cause of ACAD in adults, while Kawasaki disease is the commonest cause in children and adolescents, as well as in the Far East. Most patients are asymptomatic, but when symptoms do exist, they are usually related to myocardial ischemia. Coronary angiography is the mainstay of diagnosis, but follow up is best achieved using noninvasive imaging that does not involve exposure to radiation. The optimal management strategy in patients with ACAD remains controversial. Medical therapy is indicated for the vast majority of patients and includes antiplatelets and/or anticoagulants. Covered stents effectively limit further expansion of the affected coronary segments. Surgical ligation, resection, and coronary artery bypass grafting are appropriate for large lesions and for associated obstructive coronary artery disease. PMID:29564347

  6. Evaluation of results and radiologic follow-up in detachable balloon occlusion therapy of the internal carotid artery aneurysms

    International Nuclear Information System (INIS)

    Chung, Sun Yang; Kim, Dong Ik; Lee, Kyu Chang; Huh, Seung Kon; Yoon, Pyeong Ho; Choi, Jin Young; Kim, Dong Jun

    1999-01-01

    The author has studied the clinical results of CT and MR findings of proximal carotid artery occlusion using detachable balloons in the treatement of unclippable internal carotid (IC) aneurysms. From 1987 to 1995, twenty-eight patients with IC aneurysms were treated by proximal artery occlusion with detachable balloons. Of these patients, 4 had aneurysms arising from the supraclinoid portion of the IC artery, 23 had aneuryms arising from cavernous portion of the IC artery, and one had aneurysm arising from cervical portion of the IC artery. Of the 28 patients, 7 patients without CT or MR examinations were excluded in this study. The mean follow-up period was 18.6 months. The causes of aneurysm formation were spontaneous in 17 cases and traumatic in 4 cases. Of 20 patients with aneurysms arising from supraclinoid and cavernous portion of the IC artery, 16 patients (80%) had cranial nerve symptoms by mass effect. Five patients had epistaxis (3 patient), carotid cavernous fistula (1 patient) or subarachnoid hemorrhage (1 patient) due to aneurysm rupture. Two patients, each with aneuryms arising from supraclinoid and cervical portion of carotid artery had 9th and 12th cranial nerve symptom. There were three instances of complication after permanent occlusion; two patients had subarachnoid and intracerebral hemorrhage by aneurysm rupture and expired. One patient had ischemia of posterior cerebral artery teritorry after one day. Delayed ischemic event did not occur during the follow-up period. All aneurysms of the carotid artery below the level of ophthalmic artery presented radiographic proof of complete thrombosis within two months. However, complete thrombosis of aneurysm was considerably delayed in two aneurysms arising from the supraclinoid portion of the carotid artery. In long-term follow-up study, completely thrombosed aneurysms decreased in size slowly. But incompletely thrombosed aneurysms did not decrease in size for a long time and began to contract after

  7. Evaluation of results and radiologic follow-up in detachable balloon occlusion therapy of the internal carotid artery aneurysms

    Energy Technology Data Exchange (ETDEWEB)

    Chung, Sun Yang; Kim, Dong Ik; Lee, Kyu Chang; Huh, Seung Kon; Yoon, Pyeong Ho; Choi, Jin Young; Kim, Dong Jun [Yonsei Univ. College of Medicine, Seoul (Korea, Republic of)

    1999-06-01

    The author has studied the clinical results of CT and MR findings of proximal carotid artery occlusion using detachable balloons in the treatement of unclippable internal carotid (IC) aneurysms. From 1987 to 1995, twenty-eight patients with IC aneurysms were treated by proximal artery occlusion with detachable balloons. Of these patients, 4 had aneurysms arising from the supraclinoid portion of the IC artery, 23 had aneuryms arising from cavernous portion of the IC artery, and one had aneurysm arising from cervical portion of the IC artery. Of the 28 patients, 7 patients without CT or MR examinations were excluded in this study. The mean follow-up period was 18.6 months. The causes of aneurysm formation were spontaneous in 17 cases and traumatic in 4 cases. Of 20 patients with aneurysms arising from supraclinoid and cavernous portion of the IC artery, 16 patients (80%) had cranial nerve symptoms by mass effect. Five patients had epistaxis (3 patient), carotid cavernous fistula (1 patient) or subarachnoid hemorrhage (1 patient) due to aneurysm rupture. Two patients, each with aneuryms arising from supraclinoid and cervical portion of carotid artery had 9th and 12th cranial nerve symptom. There were three instances of complication after permanent occlusion; two patients had subarachnoid and intracerebral hemorrhage by aneurysm rupture and expired. One patient had ischemia of posterior cerebral artery teritorry after one day. Delayed ischemic event did not occur during the follow-up period. All aneurysms of the carotid artery below the level of ophthalmic artery presented radiographic proof of complete thrombosis within two months. However, complete thrombosis of aneurysm was considerably delayed in two aneurysms arising from the supraclinoid portion of the carotid artery. In long-term follow-up study, completely thrombosed aneurysms decreased in size slowly. But incompletely thrombosed aneurysms did not decrease in size for a long time and began to contract after

  8. The risk of intravenous thrombolysis-induced intracranial hemorrhage in Taiwanese patients with unruptured intracranial aneurysm.

    Directory of Open Access Journals (Sweden)

    Wei Ting Chiu

    Full Text Available The presence of an intracranial aneurysm is contraindicated to recombinant tissue plasminogen activator (r-tPA treatment for acute ischemic stroke. However, it is difficult to exclude asymptomatic intracranial aneurysms by using conventional, noncontrast head computed tomography (CT, which is the only neuroimaging suggested before r-tPA. Recent case reports and series have shown that administering r-tPA to patients with a pre-existing aneurysm does not increase the bleeding risk. However, Asians are known to have a relatively higher bleeding risk, and little evidence is available regarding the risk of using r-tPA on Asian patients with intracranial aneurysms.Medical records from the Shuang Ho hospital stroke registration between July 2010 and December 2014 were retrospectively reviewed, and 144 patients received r-tPA. Unruptured intracranial aneurysms were detected using CT, or magnetic resonance or conventional angiography after r-tPA. The primary and secondary outcomes were the difference in overall intracranial hemorrhage (ICH and symptomatic ICH after r-tPA. The differences were analyzed using Fisher's exact or Mann-Whitney U tests, and p < 0.05 was defined as the statistical significance.A total of 144 patients were reviewed, and incidental unruptured intracranial aneurysms were found in 11 of them (7.6%. No significant difference was observed in baseline demographic data between the aneurysm and nonaneurysm groups. Among patients with an unruptured aneurysm, two had giant aneurysms (7.7 and 7.4 mm, respectively. The bleeding risk was not significant different between aneurysm group (2 out of 11, 18% with nonaneurysm group (7 out of 133, 5.3% (p = 0.14. None of the patients with an unruptured aneurysm had symptomatic ICH, whereas one patient without an aneurysm exhibited symptomatic ICH.The presence of an unruptured intracranial aneurysm did not significantly increase the risk of overall and symptomatic ICH in Taiwanese patients after they

  9. Idiopathic aneurysm of pulmonary artery

    Energy Technology Data Exchange (ETDEWEB)

    Pacheco, Julio B. Cota; Pimentel, Patricia N.; Knust, Beatriz S., E-mail: jcota@uol.com.br [Clinica de Cardiologia Cota Pacheco, Mogi das Cruzes, SP (Brazil)

    2015-07-15

    Because it is a very rare isolated lesion, we decided to present this case of idiopathic pulmonary artery aneurysm (IPAA) and review the cases published in the literature in order to correlate our clinical and imaging findings, as well as management based on patient data. IPAA was first described in a case of autopsy by Bristowe in 1860 and later in 1947 by Deterling and Claggett, whose prevalence was lower than eight to one hundred thousand. Although the use of diagnostic imaging methods has been applied in a very large population in recent decades, this lesion has been most often described in postmortem examinations. Therefore, it is important to be aware of possible clinical symptoms, at times non-specific, as well as the signs on imaging studies. In this study, therefore, the report of a case of an asymptomatic patient whose diagnosis was done through color Doppler echocardiography in a routine test in 2012, later confirmed by simple chest computed tomography (chest CT) and cardiac catheterization as IPAA and its branches. We discussed the literature available and the possibilities for treatment and the use of color Doppler echocardiography as an initial diagnostic tool for such a rare and intriguing disease. (author)

  10. Interventions in Infrainguinal Bypass Grafts

    International Nuclear Information System (INIS)

    Mueller-Huelsbeck, S.; Order, B.-M.; Jahnke, T.

    2006-01-01

    The interventional radiologist plays an important role in the detection and prevention of infrainguinal bypass failure. Early detection and evaluation of flow-limiting lesions effectively preserve graft (venous bypass and polyester or expanded polytetrafluoroethylene bypass) patency by identifying stenoses before occlusion occurs. Delay in treatment of the at-risk graft may result in graft failure and a reduced chance of successful revascularization. For this reason, surveillance protocols form an important part of follow-up after infrainguinal bypass surgery. As well as having an understanding of the application of imaging techniques including ultrasound, MR angiography, CT angiography and digital subtraction angiography, the interventional radiologist should have detailed knowledge of the minimally invasive therapeutic options. Percutaneous transluminal angioplasty (PTA), or alternatively cutting balloon angioplasty, is the interventional treatment of choice in prevention of graft failure and occlusion. Further alternatives include metallic stent placement, fibrinolysis, and mechanical thrombectomy. Primary assisted patency rates following PTA can be up to 65% at 5 years. When the endovascular approach is unsuccessful, these therapeutic options are complemented by surgical procedures including vein patch revision, jump grafting, or placement of a new graft

  11. Tobacco smoking and aortic aneurysm

    DEFF Research Database (Denmark)

    Sode, Birgitte F; Nordestgaard, Børge; Grønbæk, Morten

    2013-01-01

    BACKGROUND: We determined the predictive power of tobacco smoking on aortic aneurysm as opposed to other risk factors in the general population. METHODS: We recorded tobacco smoking and other risk factors at baseline, and assessed hospitalization and death from aortic aneurysm in 15,072 individuals...... aneurysm in males and females consuming above 20g tobacco daily was 3.5% and 1.3%, among those >60years with plasma cholesterol >5mmol/L and a systolic blood pressure >140mmHg. CONCLUSIONS: Tobacco smoking is the most important predictor of future aortic aneurysm outcomes in the general population...

  12. An Animal Model of Abdominal Aortic Aneurysm Created with Peritoneal Patch: Technique and Initial Results

    International Nuclear Information System (INIS)

    Maynar, Manuel; Qian Zhong; Hernandez, Javier; Sun Fei; Miguel, Carmen de; Crisostomo, Veronica; Uson, Jesus; Pineda, Luis-Fernando; Espinoza, Carmen G.; Castaneda, Wilfrido R.

    2003-01-01

    creation of an infrarenal AAA model was developed using a peritoneal patch in swine. The aneurysm model proved to have potential for further growth of the sac and a tendency to rupture. Because of the growth potential, this might be a better model than those with a noncompliant aneurysmal wall for the preclinical evaluation of stent-graft devices

  13. Giant Coronary Artery Aneurysm Causing Acute Anterior Myocardial Infarction

    Directory of Open Access Journals (Sweden)

    Ahmet Yanık

    2016-01-01

    Full Text Available A 70-year-old man with hypertension was admitted to our coronary ICU with acute anterior MI. Emergent primary PCI was planned and coronary angiography was performed. LAD artery was totally occluded in the proximal segment just after a huge 32 × 26 mm sized aneurysm. Emergent CABG operation was performed in 75 minutes because of multivessel disease including the RCA and left circumflex artery. Aneurysm was ligated and coronary bypass was performed using LIMA and saphenous grafts. The postoperative course of the patient was uneventful. He was discharged with medical therapy including ASA, clopidogrel, and atorvastatin. He was asymptomatic at his polyclinic visit in the first month.

  14. Constipation following bilateral of internal iliac artery aneurysms

    Directory of Open Access Journals (Sweden)

    S Morita

    2012-09-01

    Full Text Available A 72-year-old man presented with constipation. He was hypertensive and suffered from chronic constipation. On arrival, the patient was fully conscious, and his vital signs were stable. He requested an enema because this treatment had proved effective in the past. On physical examination, a hard palpable mass was detected in the lower abdomen. Computed tomography was performed with contrast media. It revealed an abdominal aortic aneurysm (AAA and bilateral internal iliac artery aneurysms (IIAAs; the latter obstructing the sigmoid colon. We believe that this obstruction was the cause of constipation. The patient underwent Y-graft replacement for the treatment of the AAA and bilateral IIAAs. The surgery was successful, and constipation has not recurred since. As constipation is the most common digestive disorder in the general population, all physicians should be aware that chronic constipation can be caused by bilateral IIAAs.

  15. Conventional and cine-MRI in patients with aneurysms of the abdominal aorta

    International Nuclear Information System (INIS)

    Gross-Fengels, W.; Friedmann, G.; Lemaitre, F.; Schmidt, R.; Lanfermann, H.; Erasmi, H.; Koeln Univ.

    1991-01-01

    We studied 40 patients with aneurysms of the abdominal aorta by MRI. These results were compared with those obtained by real-time sonography (n = 40), angiography (n = 32) and CT (n = 16). In 30 patients the imaging results were compared - as far as possible - with the operative findings. MRI proved more reliable, especially if compared with sonography, in evaluating renal or iliac artery involvement. Mural thrombi were detected more often (93%) by MRI than by CT (85%) or sonography (83%). Cine-MRI showed strong turbulences in 33%. Turbulences did not correlate with the size of the aneurysm. (orig.) [de

  16. Usefulness of virtual endoscopy for evaluating the relationship between the neck of intracranial aneurysm and surrounding vessels

    International Nuclear Information System (INIS)

    Ikeda, Jota; Horie, Hitoshi; Ishikura, Reiichi; Ando, Kumiko; Morikawa, Tsutomu; Tominaga, Satoru; Nakao, Norio

    2000-01-01

    Application of three-dimensional CT virtual endoscopy for evaluation of the neck and surrounding vessels of intracranial aneurysms. 3D-CT virtual endoscopy (VE) is a reconstructed image using computer processing of 3D-CT images. We evaluated the usefulness of a virtual endoscopy to analyze the relationship between the neck of an intracranial aneurysm and the surrounding vessels. Eight cases with intracranial aneurysms underwent digital subtraction angiography (DSA) and enhanced CT with transarterial infusion of contrast media. 3D-CT angiogram (3D-CTA) and virtual endoscopic images were obtained from the CT image data sets using surface rendering method. The relationship between the neck of an intracranial aneurysm and the surrounding vessels was confirmed by operation or IVR. VE clearly visualized the neck and surrounding vessels in all cases. Operation/IVR findings agreed with the virtual endoscopic findings in all cases, but not with the DSA or 3D-CTA findings in 4 and 2 cases, respectively. 3D-CTA and virtual endoscopy clearly visualizes the relationship between cerebral aneurysms and surrounding vessels, which is useful for determining IVR procedures. (author)

  17. A case of megadolichobasilar anomaly complicated with abdominal aortic aneurysm

    International Nuclear Information System (INIS)

    Ohta, Sumio; Yamaguchi, Takenori; Ogata, Jun; Ito, Mamoru; Kikuchi, Haruhiko

    1985-01-01

    A 41 year-old hypertensive male was admitted because of progressing left hemiparesis and dysarthria. CT demonstrated hyperdense mass with partial contast enhancement, extending from the level of lower pons to that of suprasellar cistern. Reconstructed imaging of CT showed a huge mass lesion, in which a wide curvilinear hyperdensity was demonstrated by contrast enhancement. Cerebral angiography revealed markedly elongated and dilated basilar and carotid arteries. From these findings, the prepontine hyperdense mass lesion was diagnosed as megadolichobasilar anomaly with marked wall thickening. Findings of abdominal aortic angiography and abdominal CT suggested the presence of marked atherosclerosis and abdominal aortic aneurysm with mural thrombi. Six months after initial admission, neurological symptoms gradually deteriorated and CT showed dilatation of the 3rd and lateral ventricles, suggesting the development of hydrocephalus due to compression of the aqueduct by the megadolichobasilar anomaly. Magnetic resonance imaging at this time demonstrated more details of the lesion and the deformity of the brain stem, which was not detected by conventional CT. Complications of vascular anomalies other than intracranial vasculature, such as aortic aneurysm, have also been repoted. After the introduction of CT, demonstration of a long, wide, curvilinear structure with abnormal density in the prepontine region has been reported to be diagnostic for the megadolichobasilar anomaly. This patient has had hypertension for 10 years, which probably due to chronic nephritis. He had no definite findings for angitis, but had abdominal aortic aneurysm with mural thrombi. From these findings, atherosclerosis of large vessels may have played one of the roles in the pathogenesis of this anomaly in the present case. (J.P.N.)

  18. Hybrid repair of a very late, post-aortic coarctation surgery thoracic aneurysm: a case report

    Directory of Open Access Journals (Sweden)

    Tilea Ioan

    2012-08-01

    Full Text Available Abstract Introduction Local aneurysms after surgical repair of coarctation of the aorta occur mainly in patients surgically treated by Dacron patch plasty during adulthood. The management of these patients is always problematic, with frequent complications and increased mortality rates. Percutaneous stent-graft implantation avoids the need for surgical reintervention. Case presentation We report a case involving the hybrid treatment by stent-graft implantation and transposition of the left subclavian artery to the left common carotid artery of an aneurysmal dilatation of the thoracic aorta that occurred in a 64-year-old Caucasian man, operated on almost 40 years earlier with a Dacron patch plasty for aortic coarctation. Our patient presented to our facility for evaluation with back pain and shortness of breath after minimal physical effort. A physical examination revealed stony dullness to percussion of the left posterior thorax, with no other abnormalities. The results of chest radiography, followed by contrast-enhanced computed tomography and aortography, led to a diagnosis of giant aortic thoracic aneurysm. Successful treatment of the aneurysm was achieved by percutaneous stent-graft implantation combined with transposition of the left subclavian artery to the left common carotid artery. His post-procedural recovery was uneventful. Three months after the procedure, computed tomography showed complete thrombosis of the excluded aneurysm, without any clinical signs of left lower limb ischemia or new onset neurological abnormalities. Conclusions Our patient’s case illustrates the clinical outcomes of surgical interventions for aortic coarctation. However, the very late appearance of a local aneurysm is rather unusual. Management of such cases is always difficult. The decision-making should be multidisciplinary. A hybrid approach was considered the best solution for our patient.

  19. Mycotic aneurysm in a turtle hunter: brief review and a case report

    Directory of Open Access Journals (Sweden)

    Harsha Moole

    2015-06-01

    Full Text Available Salmonella-associated mycotic aneurysm is a rare, but dreaded, complication of salmonellosis. Immunocompromised and elderly populations are more susceptible to develop this extra-intestinal complication. Salmonella is spread via fecal–oral and vehicle-borne routes. Reptiles, especially small pet turtles, have been linked with an increased risk of Salmonella infection. Diagnosis of mycotic aneurysm is a challenge due to atypical presentations. Recently, widespread use of CT scan imaging to evaluate for unexplained abdominal pain and sepsis has led to early identification of mycotic aneurysms. Antibiotic therapy and surgical intervention are the cornerstones of management. Open surgery has been the gold standard of treatment but is associated with increased morbidity and mortality. A relatively new alternative to open surgery is endovascular aneurysm repair (EVAR. It is comparatively less invasive and is associated with reduced early morbidity and mortality in the setting of mycotic aneurysm. However, there is a risk of late infection. Here, we present a patient with Salmonella mycotic aneurysm initially treated conservatively with antibiotic therapy who later underwent successful interval EVAR with no complications to date. Also included is a brief review of Salmonella-associated mycotic aneurysms.

  20. Management of ruptured anterior communicating artery aneurysms presenting with sudden paraplegia

    Directory of Open Access Journals (Sweden)

    Jiu-hong MA

    2016-10-01

    Full Text Available Objective  To explore the causes of ruptured anterior communicating artery aneurysms presenting with paraplegia, and summarize the key points of diagnosis and treatment methods. Methods  A total of 260 patients with ruptured anterior communicating artery aneurysms were received medical treatment in the Department of Neurosurgery, Shanxi Provincial People's Hospital from Jan. 2012 to Mar. 2015. Of which 6 patients were clinically presented with paraplegia, their clinical data including CT/MR/DSA were retrospectively analyzed, and based on the analysis, aneurysm embolization and anti-vasospasm treatment were performed. Results  Besides headache and discomfort in the neck, 5 of the 6 patients were with double lower limbs paraplegia, and the another one presented quadriplegia. By symptomatic treatment of aneurysm embolization and anti vasospasm, the myodynamia of the paraplegic limbs recovered from 0-Ⅰto Ⅳ-Ⅴgrade, and 2 of the 6 patients spent a shorter recovery time (about 2 weeks, the other 4 recovered in 3 months. The limbs myodynamia of the 6 patients recovered completely in half-and one year follow up. Conclusions  The mechanism of ruptured anterior communicating artery aneurysms presenting with paraplegia may be the insufficient blood supply to the primary motor area and supplementary motor area (SMA of brain cortex caused by aneurysms rupture. Aneurysm embolization should be performed in clinical treatment, supplemented with anti vasospasm and symptomatic treatment of improving neurological function. DOI: 10.11855/j.issn.0577-7402.2016.09.14

  1. Cerebral aneurysms – an audit

    African Journals Online (AJOL)

    Enrique

    Abstract. We performed an audit to determine the profile of cerebral aneurysms at the Universitas Hospital Bloem- fontein, the only government hospital with a vascular suite in the Free State and Northern Cape area. Two hun- dred and twenty-three government patients, diagnosed with cerebral aneurysms during the period.

  2. JAG Tearing Technique with Radiofrequency Guide Wire for Aortic Fenestration in Thoracic Endovascular Aneurysm Repair

    International Nuclear Information System (INIS)

    Ricci, Carmelo; Ceccherini, Claudio; Leonini, Sara; Cini, Marco; Vigni, Francesco; Neri, Eugenio; Tucci, Enrico; Benvenuti, Antonio; Tommasino, Giulio; Sassi, Carlo

    2012-01-01

    An innovative approach, the JAG tearing technique, was performed during thoracic endovascular aneurysm repair in a patient with previous surgical replacement of the ascending aorta with a residual uncomplicated type B aortic dissection who developed an aneurysm of the descending thoracic aorta with its lumen divided in two parts by an intimal flap. The proximal landing zone was suitable to place a thoracic stent graft. The distal landing zone was created by cutting the intimal flap in the distal third of the descending thoracic aorta with a radiofrequency guide wire and intravascular ultrasound catheter.

  3. Emergency endovascular management of peripheral artery aneurysms and pseudoaneurysms – a review

    Directory of Open Access Journals (Sweden)

    Gillard Jonathan H

    2008-07-01

    Full Text Available Abstract Endovascular stenting has been successfully employed in the management of aortic aneurysms; however, its use in managing peripheral arterial conditions remains questionable. We review the utility of endovascular technique in the management of peripheral arterial conditions like aneurysms, pseudoaneurysms and arterio-venous fistulas in the emergency setting. Though long term data about graft patency rates is not yet available, the endovascular approach appears to be a useful minimally invasive technique in situations where open repair is either difficult or not feasible.

  4. Unruptured Cerebral Aneurysm Detected after Intravenous Tissue Plasminogen Activator for Stroke

    Directory of Open Access Journals (Sweden)

    Yukihiro Yoneda

    2009-06-01

    Full Text Available Therapeutic guidelines of intravenous thrombolysis with tissue plasminogen activator (tPA for hyperacute ischemic stroke are very strict. Because of potential higher risk of bleeding complications, the presence of unruptured cerebral aneurysm is a contraindication for systemic thrombolysis with tPA. According to the standard CT criteria, a 66-year-old woman who suddenly developed aphasia and hemiparesis received intravenous tPA within 3 h after ischemic stroke. Magnetic resonance angiography during tPA infusion was performed and the presence of a small unruptured cerebral aneurysm was suspected at the anterior communicating artery. Delayed cerebral angiography confirmed an aneurysm with a size of 7 mm. The patient did not experience any adverse complications associated with the aneurysm. Clinical experiences of this kind of accidental off-label thrombolysis may contribute to modify the current rigid tPA guidelines for stroke.

  5. Asymptomatic Delayed Coil Migration from an Intracranial Aneurysm: A Case Report

    Directory of Open Access Journals (Sweden)

    Anirban Deep Banerjee

    2011-01-01

    Full Text Available Objective. To describe asymptomatic delayed migration of a coil loop in a patient following successful coil embolization of an anterior communicating artery saccular aneurysm. Methods. A 24-year-old man with a ruptured anterior communicating artery saccular aneurysm underwent coil embolization with one helical ultrasoft coil. Results. A followup CT scan head and a cerebral angiogram one month following the procedure revealed distal migration of an intra-aneurysmal coil loop into the left pericallosal artery. The patient, however, remained asymptomatic. Conclusion. Delayed migration of coil following embolization of an intracranial aneurysm is an extremely rare occurrence. An asymptomatic presentation, as in our patient, is even more unique. The stent-like configuration of the migrated spiral coil loop probably prevented complete occlusion of the blood vessel.

  6. Call-Fleming Syndrome (Reversible Cerebral Artery Vasoconstriction and Aneurysm Associated with Multiple Recreational Drug Use

    Directory of Open Access Journals (Sweden)

    Doniel Drazin

    2013-01-01

    Full Text Available Drug abuse represents a significant health issue. Evidence suggests that recreational drug use has a direct effect on the cerebral vasculature and is of greater concern in those with undiagnosed aneurysms or vascular malformations. The authors report a case of thunderclap headache with a negative head CT and equivocal lumbar puncture after a drug-fueled weekend. The patient underwent diagnostic cerebral angiogram which demonstrated multisegmental, distal areas of focal narrowing of the middle, anterior, posterior, and posterior inferior cerebral artery and an incidental aneurysm. It is often difficult to determine the exact origin of symptoms; thus we were left with a bit of a chicken or the egg debate, trying to decipher which part came first. Either the aneurysm ruptured with associated concomitant vasospasm or it is a case of Call-Fleming syndrome (reversible cerebral artery vasoconstriction with an incidental aneurysm. The authors proposed their management and rationale of this complex case.

  7. Stent graft placement for dysfunctional arteriovenous grafts

    Energy Technology Data Exchange (ETDEWEB)

    Jeon, Gyeong Sik [Dept. of Radiology, CHA Bundang Medical Center, College of Medicine, CHA University, Seongnam (Korea, Republic of); Shin, Byung Seok; Ohm, Joon Young; Ahn, Moon Sang [Chungnam National University Hospital, Daejeon (Korea, Republic of)

    2015-07-15

    This study aimed to evaluate the usefulness and outcomes of stent graft use in dysfunctional arteriovenous grafts. Eleven patients who underwent stent graft placement for a dysfunctional hemodialysis graft were included in this retrospective study. Expanded polytetrafluoroethylene covered stent grafts were placed at the venous anastomosis site in case of pseudoaneurysm, venous laceration, elastic recoil or residual restenosis despite the repeated angioplasty. The patency of the arteriovenous graft was evaluated using Kaplan-Meier analysis. Primary and secondary mean patency was 363 days and 741 days. Primary patency at 3, 6, and 12 months was 82%, 73%, and 32%, respectively. Secondary patency at the 3, 6, 12, 24, and 36 months was improved to 91%, 82%, 82%, 50%, and 25%, respectively. Fractures of the stent graft were observed in 2 patients, but had no effect on the patency. Stent graft placement in dysfunctional arteriovenous graft is useful and effective in prolonging graft patency.

  8. Dilatation of aortic grafts over time: what to expect and when to be concerned

    DEFF Research Database (Denmark)

    Schroeder, Torben V; Eldrup, Nikolaj; Just, Sven

    2009-01-01

    Dilatation of aortic prosthetic grafts is commonly reported, but most reports are anecdotal, with little objective data in the literature. We performed a prospective trial of 303 patients who underwent prosthetic graft repair for aortic aneurysm or occlusive disease, randomizing patients between...... insertion of a woven polyester or expanded polytetrafluoroethylene (ePTFE) graft. Patients were followed with computed tomography and ultrasonography for up to 5 years in order to assess the frequency and magnitude of postoperative dilatation. Graft dilatation was documented in patients with polyester...... grafts at 12 months. Thereafter and up to 60 months, polyester grafts did not dilate further. After 5 years, polyester prostheses had dilated by 25% and ePTFE by 12.5%, as determined by computed tomography imaging. These observations suggest that dilatation of prosthetic grafts is more frequent...

  9. Angiographic Evaluation of Carotid Artery Grafting with Prefabricated Small-Diameter, Small-Intestinal Submucosa Grafts in Sheep

    International Nuclear Information System (INIS)

    Pavcnik, Dusan; Obermiller, Josef; Uchida, Barry T.; Van Alstine, William; Edwards, James M.; Landry, Gregory J.; Kaufman, John A.; Keller, Frederick S.; Roesch, Josef

    2009-01-01

    The purpose of this study was to report the longitudinal angiographic evaluation of prefabricated lyophilized small-intestinal submucosa (SIS) grafts placed in ovine carotid arteries and to demonstrate a variety of complications that developed. A total of 24 grafts, 10 cm long and 6 mm in diameter, were placed surgically as interposition grafts. Graft patency at 1 week was evaluated by Doppler ultrasound, and angiography was used for follow-up at 1 month and at 3 to 4 months. A 90% patency rate was found at 1 week, 65% at 1 month, and 30% at 3 to 4 months. On the patent grafts, angiography demonstrated a variety of changes, such as anastomotic stenoses, graft diffuse dilations and dissections, and aneurysm formation. These findings have not been previously demonstrated angiographically by other investigators reporting results with small-diameter vessel grafts made from fresh small-intestinal submucosa (SIS). The complications found were partially related to the graft construction from four SIS layers. Detailed longitudinal angiographic study should become an essential part of any future evaluation of small-vessel SIS grafting.

  10. Chronic contained rupture of abdominal aortic aneurysm (CCR-AAA) with massive vertebral bone erosion: computed tomography (CT), magnetic resonance imaging (MRI) and fluorine-18-fluorodeoxyglucose positron emission tomography (FDG-PET) findings.

    Science.gov (United States)

    Nakano, Sachiko; Okauchi, Kenzo; Tsushima, Yoshito

    2014-02-01

    A 62-year-old male presented with sudden onset of low back and right leg pain. Contrast-enhanced computed tomography demonstrated an abdominal aortic aneurysm (AAA), along with a large mass lesion causing vertebral body erosion. Magnetic resonance imaging (MRI) suggested that the mass lesion consisted of a chronic hematoma. Fluorine-18-fluorodeoxyglucose positron emission tomography (FDG-PET) demonstrated increased uptake around the mass lesion, but not around the AAA. Surgical intervention was performed, and the subsequent histological diagnosis was chronic contained rupture of AAA. The mass lesion consisted of chronic hematoma and necrosis with inflammatory cell infiltration and hemosiderin deposition. This condition mimics some neoplastic diseases, but MRI and FDG-PET findings may help establish the correct diagnosis.

  11. Chronic contained rupture of abdominal aortic aneurysm (CCR-AAA) with massive vertebral bone erosion. Computed tomography (CT), magnetic resonance imaging (MRI) and fluorine-18-fluorodeoxyglucose positron emission tomography (FDG-PET) findings

    International Nuclear Information System (INIS)

    Nakano, Sachiko; Okauchi, Kenzo; Tsushima, Yoshito

    2014-01-01

    A 62-year-old male presented with sudden onset of low back and right leg pain. Contrast-enhanced computed tomography demonstrated an abdominal aortic aneurysm (AAA), along with a large mass lesion causing vertebral body erosion. Magnetic resonance imaging (MRI) suggested that the mass lesion consisted of a chronic hematoma. Fluorine-18-fluorodeoxyglucose positron emission tomography (FDG-PET) demonstrated increased uptake around the mass lesion, but not around the AAA. Surgical intervention was performed, and the subsequent histological diagnosis was chronic contained rupture of AAA. The mass lesion consisted of chronic hematoma and necrosis with inflammatory cell infiltration and hemosiderin deposition. This condition mimics some neoplastic diseases, but MRI and FDG-PET findings may help establish the correct diagnosis. (author)

  12. Simultaneous or Early Sequential Rupture of Multiple Intracranial Aneurysms: A Rare and Insufficiently Understood Entity.

    Science.gov (United States)

    Hou, Kun; Zhao, Jinchuan; Zhang, Yang; Zhu, Xiaobo; Zhao, Yan; Li, Guichen

    2016-05-01

    Simultaneous or early sequential rupture of multiple intracranial aneurysms (MIAs) is encountered rarely, with no more than 10 cases having been reported. As a result of its rarity, there are a lot of questions concerning this entity need to be answered. A 67-year-old woman was admitted to the First Hospital of Jilin University (Eastern Division) from a local hospital after a sudden onset of severe headache, nausea, and vomiting. Head computed tomography (CT) at the local hospital revealed diffuse subarachnoid hemorrhage (SAH) that was concentrated predominately in the suprasellar cistern and interhemispheric fissure. During her transfer to our hospital, she experienced another episode of sudden headache. CT on admission to our hospital revealed that the SAH was increased with 2 isolated hematomas both in the interhemispheric fissure and the left paramedian frontal lobe. Further CT angiography and intraoperative findings were in favor of early sequential rupture of 2 intracranial aneurysms. To further elucidate the characteristics, mechanism, management, and prognosis of this specific entity, we conducted a comprehensive review of the literature. The mechanism of simultaneous or early sequential rupture of MIAs is still obscure. Transient elevation of blood pressure might play a role in the process, and preventing the sudden elevation of blood pressure might be beneficial for patients with aneurysmal SAH and MIAs. The management of simultaneously or early sequentially ruptured aneurysms is more complex for its difficulty in responsible aneurysm determination, urgency in treatment, toughness in intraoperative manipulation and poorness in prognosis. Copyright © 2016 Elsevier Inc. All rights reserved.

  13. Gastroduodenal artery aneurysm - Post traumatic pancreatic pseudocyst drainage - An interesting case.

    Science.gov (United States)

    Zarin, Mohammad; Ali, Sajid; Majid, Abdul; Jan, ZakaUllah

    2018-01-01

    Pseudoaneurysms of the gastroduodenal artery (GDA) are rare and mostly associated with pancreatitis. However, they can occur as a possible complication following gastric or pancreatic surgery and thus prior recognition and prompt treatment is mandatory (Lee et al., 2009 [1]). We report a case of a ruptured GDA aneurysm in a patient who underwent roux-en-y-cystojejunostomy for traumatic pancreatic pseudocyst and this has rarely been reported in the literature. Our patient presented with melena one month post operatively. CT Angiogram showed pseudoaneurysm of the GDA and the origin of right gastroepiploic artery which was embolised. Our case highlights that GDA aneurysm must be considered in the differential for a patient who presents with melena following drainage of traumatic pancreatic pseudocyst and that it can be managed successfully with angioembolization. A young boy was operated for traumatic pancreatic pseudocyst. One month later, he presented with the complaints of melena. Patient was resuscitated initially and then CT Angiogram was planned that showed pseudo aneurysm of the GDA and the origin of right gastroepiploic artery. The aneurysm was embolised and patient was sent home later on. On two months follow up the patient was doing well and had no episode of melena. GDA aneurysm are rare and should be suspected in a patient with GI hemorrhage after surgery for traumatic pancreatic pseudocyst. The investigation of choice is CT Angiography and endovascular angioembolization is the treatment modality of choice. Copyright © 2017. Published by Elsevier Ltd.

  14. Technical and clinical success of infrarenal endovascular abdominal aortic aneurysm repair: A 10-year single-center experience

    International Nuclear Information System (INIS)

    Steingruber, I.E.; Neuhauser, B.; Seiler, R.; Greiner, A.; Chemelli, A.; Kopf, H.; Walch, C.; Waldenberger, P.; Jaschke, W.; Czermak, B.

    2006-01-01

    Objective: The aim of our retrospective study was to review our single-center experience with aortic abdominal aneurysm (AAA) repair retrospectively. Material and methods: From 1995 to 2005, 70 consecutive patients affected by AAA were treated by endovascular stent-graft repair. Mean follow-up was 23.9 months. Follow-up investigations were performed at 6 and 12 months and yearly thereafter. Five different stent-graft designs were compared to each other. Primary technical success (PTS), assisted primary technical success (APTS), primary clinical success (PCS) and secondary clinical success (SCS) were evaluated. Results: All over PTS was achieved in 94.3%, APTS in 97.1%, PCS in 61.4%, APCS in 64.3% and SCS in 70%. There were 3 type I endoleaks, 25 type II endoleaks, 4 type III endoleaks, 8 limb problems, 5 conversions to open surgery, 10 aneurysm sac expansions and 14 device migrations. Patients with newer generation devices showed better results than patients with first generation prosthesis. In addition results were better for grafts with suprarenal fixation (versus infrarenal fixation) and grafts with barbs and hooks (versus grafts without barbs and hooks). Patients with bad anatomic preconditions showed a higher complication rate. Conclusion: Contrary to first generation products, new stent-graft designs show acceptable technical and clinical results in endovascular AAA aneurysm repair. However, this therapy still should be reserved only for patients with significant comorbities and suitable anatomic conditions

  15. Technical and clinical success of infrarenal endovascular abdominal aortic aneurysm repair: A 10-year single-center experience

    Energy Technology Data Exchange (ETDEWEB)

    Steingruber, I.E. [Department of Radiology, University Hospital Innsbruck, Anichstr. 35, A-6020 Innsbruck (Austria)]. E-mail: iris.steingruber@uibk.ac.at; Neuhauser, B. [Department of Vascular Surgery, University Hospital Innsbruck, Anichstr. 35, A-6020 Innsbruck (Austria); Seiler, R. [Department of Vascular Surgery, University Hospital Innsbruck, Anichstr. 35, A-6020 Innsbruck (Austria); Greiner, A. [Department of Vascular Surgery, University Hospital Innsbruck, Anichstr. 35, A-6020 Innsbruck (Austria); Chemelli, A. [Department of Radiology, University Hospital Innsbruck, Anichstr. 35, A-6020 Innsbruck (Austria); Kopf, H. [Department of Radiology, University Hospital Innsbruck, Anichstr. 35, A-6020 Innsbruck (Austria); Walch, C. [Department of Radiology, University Hospital Innsbruck, Anichstr. 35, A-6020 Innsbruck (Austria); Waldenberger, P. [Department of Radiology, University Hospital Innsbruck, Anichstr. 35, A-6020 Innsbruck (Austria); Jaschke, W. [Department of Radiology, University Hospital Innsbruck, Anichstr. 35, A-6020 Innsbruck (Austria); Czermak, B. [Department of Radiology, University Hospital Innsbruck, Anichstr. 35, A-6020 Innsbruck (Austria)

    2006-09-15

    Objective: The aim of our retrospective study was to review our single-center experience with aortic abdominal aneurysm (AAA) repair retrospectively. Material and methods: From 1995 to 2005, 70 consecutive patients affected by AAA were treated by endovascular stent-graft repair. Mean follow-up was 23.9 months. Follow-up investigations were performed at 6 and 12 months and yearly thereafter. Five different stent-graft designs were compared to each other. Primary technical success (PTS), assisted primary technical success (APTS), primary clinical success (PCS) and secondary clinical success (SCS) were evaluated. Results: All over PTS was achieved in 94.3%, APTS in 97.1%, PCS in 61.4%, APCS in 64.3% and SCS in 70%. There were 3 type I endoleaks, 25 type II endoleaks, 4 type III endoleaks, 8 limb problems, 5 conversions to open surgery, 10 aneurysm sac expansions and 14 device migrations. Patients with newer generation devices showed better results than patients with first generation prosthesis. In addition results were better for grafts with suprarenal fixation (versus infrarenal fixation) and grafts with barbs and hooks (versus grafts without barbs and hooks). Patients with bad anatomic preconditions showed a higher complication rate. Conclusion: Contrary to first generation products, new stent-graft designs show acceptable technical and clinical results in endovascular AAA aneurysm repair. However, this therapy still should be reserved only for patients with significant comorbities and suitable anatomic conditions.

  16. Long-term results after repair of ruptured and non-ruptured abdominal aortic aneurysm

    Directory of Open Access Journals (Sweden)

    Kuzmanović Ilija B.

    2004-01-01

    Full Text Available INTRODUCTION Abdominal aortic aneurysm can be repaired by elective procedure while asymptomatic, or immediately when it is complicated - mostly due to rupture. Treating abdominal aneurysm electively, before it becomes urgent, has medical and economical reason. Today, the first month mortality after elective operations of the abdominal aorta aneurysm is less than 3%; on the other hand, significant mortality (25%-70% has been recorded in patients operated immediately because of rupture of the abdominal aneurysm. In addition, the costs of elective surgical treatment are significantly lower. OBJECTIVE The objective of this study is to compare long-term survival of patients that underwent elective or immediate repair of abdominal aortic aneurysm (due to rupture, and to find out the factors influencing the long-term survival of these patients. MATERIAL AND METHODS Through retrospective review of prospectively collected data of the Institute for Cardiovascular Diseases of Clinical Center of Serbia, Belgrade, 56 patients that had elective surgery and 35 patients that underwent urgent operation due to rupture of abdominal aneurysm were followed up. Only the patients that survived 30 postoperative days were included in this review, and were followed up (ranging from 2 to 126 months. Electively operated patients were followed during 58.82 months on the average (range 7 to 122, and urgently operated were followed over 52.26 months (range 2 to 126. There was no significant difference of the length of postoperative follow-up between these two groups. RESULTS During this period, out of electively operated and immediately operated patients, 27 and 22 cases died, respectively. There was no significant difference (p>0,05a of long-term survival between these two groups. Obesity and early postoperative complications significantly decreased long-term survival of both electively and immediately operated patients. Graft infection, ventral hernia, aneurysm of

  17. Detection of intracranial aneurysms with 64 channel multidetector row computed tomography: Comparison with digital subtraction angiography

    International Nuclear Information System (INIS)

    Pozzi-Mucelli, Fabio; Bruni, Stefano; Doddi, Marco; Calgaro, Antonio; Braini, Massimiliano; Cova, Maria

    2007-01-01

    Purpose: To compare the contribution of 64 channel multidetector row computed tomography angiography (64MDCT-angiography) with digital subtraction angiography (DSA) in the detection of intracranial aneurysms. Methods and materials: Twenty-nine patients (10 males and 19 females, age: 40-84 years; average: 61.9 years) with clinical and imaging findings strongly suggesting the presence of subaracnoid hemorrhage underwent 64MDCT-angiography and DSA with a short interval between the two examinations (less than 12 h-5 days). CT parameters were: 64 mm x 0.5 mm collimation, pitch-0.828 and helical pitch-53. DSA were performed with standard technique (four vessel catheterization) and multiple projections. Axial CT scans as well as maximum intensity projection, volume rendering and multiplanar reformations and angiographic views were independently reviewed by four readers (two for 64MDCT-angiography and two for DSA). Consensus was reached for discordant cases. DSA was considered as the standard of reference. Results: In 29 patients, 28 aneurysms were found (14 patients had 1 aneurysm, 4 patients had 2 aneurysms and 2 patients had 3 aneurysms; in 9 patients no aneurysm were found). 64MDCT-angiography detected 26/28 aneurysms. No false-positive sites were recognized. The sensitivity, specificity, positive and negative predictive values and diagnostic accuracy were, respectively, 92.8, 100, 100, 99.4 and 99.5%. Conclusions: 64MDCT-angiography is helpful in detecting intracranial aneurysms with results similar to those of DSA but with less discomfort and risks for the patients and can be considered for the first line imaging technique. Conventional angiography is still needed in doubtful cases or negative MDCT-angiography associated with a strong clinical suspect

  18. Bilateral axillary artery aneurysms after Bentall procedure in Marfan syndrome.

    Science.gov (United States)

    Haruki, Takashi; Ito, Hiroshi; Sakata, Kensuke; Kobayashi, Yurio

    2015-11-01

    A man with Marfan syndrome underwent a Bentall procedure for annuloaortic ectasia and severe aortic regurgitation at 43 years of age. Twenty-eight years after the Bentall procedure, he developed bilateral axillary artery aneurysms (length × diameter: right: 80 × 39 mm; left: 103 × 45 mm). Aneurysmectomy and reconstruction of the axillary artery were performed using an artificial vascular graft. Histological examination revealed cystic medial necrosis. The postoperative course was uneventful, but long-term follow-up is necessary. © The Author(s) 2014.

  19. Matrix metalloproteinase-2 gene variants and abdominal aortic aneurysm.

    Science.gov (United States)

    Smallwood, L; Warrington, N; Allcock, R; van Bockxmeer, F; Palmer, L J; Iacopetta, B; Golledge, J; Norman, P E

    2009-08-01

    To investigate associations between two polymorphisms of the matrix metalloproteinase-2 gene (MMP2) and the incidence and progression of abdominal aortic aneurysm (AAA). Cases and controls were recruited from a trial of screening for AAAs. The association between two variants of MMP2 (-1360C>T, and +649C>T) in men with AAA (n=678) and in controls (n=659) was examined using multivariate analyses. The association with AAA expansion (n=638) was also assessed. In multivariate analyses with adjustments for multiple testing, no association between either SNP and AAA presence or expansion was detected. MMP2 -1360C>T and +649C>T variants are not risk factors for AAA.

  20. Treatment of a Chronic Aneurysmal Aortic Dissection in a Patient with Marfan Syndrome Using a Staged Hybrid Procedure and a Fenestrated Endograft

    International Nuclear Information System (INIS)

    Walkden, R. Miles; Morgan, Rob A.; Loftus, Ian; Thompson, Matt

    2008-01-01

    Patients with aneurysmal dissections involving both the thoracic and the abdominal aorta are particularly challenging to treat with endovascular techniques because of the natural communications at the level of the visceral arteries. We present the case of a patient with Marfan syndrome with an aneurysmal aortic dissection involving the thoracic and abdominal aorta who was treated by a combination of endografts, surgical bypass, and a fenestrated tube graft.

  1. Traumatic aneurysms of the internal carotid artery at the base of the skull. Two cases treated surgically.

    Science.gov (United States)

    Magnan, P E; Branchereau, A; Cannoni, M

    1992-01-01

    Internal carotid aneurysms at the base of the skull after blunt trauma are infrequent but their management is difficult, leading many surgeons to only attempt ligation. We report 2 cases presenting with high traumatic aneurysms, following motorcycle accidents. The 2 aneurysms underwent repair by a venous graft. The petrous portion of the carotid artery was approached and controlled by an ENT surgeon. This "infratemporal" approach was used exposing the facial nerve, combined with temporary anterior sub-luxation of the temporomaxillary joint to expose the lower part of the carotid canal which was opened up with a drill in order to control the carotid artery in the petrous canal. Both patients developed facial nerve palsies which improved within 3 months. Postoperative angiography showed patent vein grafts and the patients were doing well, without any symptoms 18 and 24 months later.

  2. Postoperative CT in pancreas transplantation

    International Nuclear Information System (INIS)

    Powell, F.E.; Harper, S.J.F.; Callaghan, C.J.; Shaw, A.; Godfrey, E.M.; Bradley, J.A.; Watson, C.J.E.; Pettigrew, G.J.

    2015-01-01

    Aim: To examine the usage and value of computed tomography (CT) following simultaneous pancreas and kidney (SPK) transplantation. Materials and methods: Indications for postoperative CT, key findings, and their influence on management were determined by retrospective analysis. Results: Ninety-eight patients underwent 313 CT examinations. Common indications for the examinations included suspected intra-abdominal collection (31.1%) and elevated serum amylase/lipase (24.1%). CT findings most frequently showed non-specific mild inflammation (27.6%), a normal scan (17.1%) and fluid collections (16.3%). High capillary blood glucose (CBG) was associated with resultant CT demonstration of graft vascular abnormalities, but otherwise, particular clinical indications were not associated with specific CT findings. Conclusion: Clinical findings in patients with SPK transplants are non-specific. The pattern of abnormalities encountered is significantly different to those seen in native pancreatic disease and demands a tailored protocol. CT enables accurate depiction of vascular abnormalities and fluid collections, thus reducing the number of surgical interventions that might otherwise be required. Elevated CBG should prompt urgent CT to exclude potentially reversible vascular complications. - Highlights: • The value of CT following simultaneous pancreas and kidney transplantation was assessed. • 313 CT scans were performed on 98 patients between January 2005 and August 2010. • Elevated blood glucose was associated with CT findings of graft vascular anomalities. • CT was particularly useful in directing operative versus non-operative intervention.

  3. Mycotic aneurysm of the popliteal artery secondary to Streptococus pneumoniae: a case report and review of the literature.

    LENUS (Irish Health Repository)

    Killeen, Shane D

    2009-01-01

    Cases of true mycotic popliteal artery aneurysm are rare. Presentation is variable but invasive and non-invasive investigations collectively facilitate diagnosis and guide operative procedures. Definitive treatment generally utilizes surgical intervention with excision and reconstruction using autologous vein graft. Prolonged targeted antibiotic therapy is an important adjuvant.

  4. ''de novo'' aneurysms following endovascular procedures

    Energy Technology Data Exchange (ETDEWEB)

    Briganti, F.; Cirillo, S.; Caranci, F. [Department of Neurological Sciences, Services of Neuroradiology, ' ' Federico II' ' University, Naples (Italy); Esposito, F.; Maiuri, F. [Department of Neurological Sciences, Services of Neurosurgery, ' ' Federico II' ' University, Naples (Italy)

    2002-07-01

    Two personal cases of ''de novo'' aneurysms of the anterior communicating artery (ACoA) occurring 9 and 4 years, respectively, after endovascular carotid occlusion are described. A review of the 30 reported cases (including our own two) of ''de novo'' aneurysms after occlusion of the major cerebral vessels has shown some features, including a rather long time interval after the endovascular procedure of up to 20-25 years (average 9.6 years), a preferential ACoA (36.3%) and internal carotid artery-posterior communicating artery (ICA-PCoA) (33.3%) location of the ''de novo'' aneurysms, and a 10% rate of multiple aneurysms. These data are compared with those of the group of reported spontaneous ''de novo'' aneurysms after SAH or previous aneurysm clipping. We agree that the frequency of ''de novo'' aneurysms after major-vessel occlusion (two among ten procedures in our series, or 20%) is higher than commonly reported (0 to 11%). For this reason, we suggest that patients who have been submitted to endovascular major-vessel occlusion be followed up for up to 20-25 years after the procedure, using non-invasive imaging studies such as MR angiography and high-resolution CT angiography. On the other hand, periodic digital angiography has a questionable risk-benefit ratio; it may be used when a ''de novo'' aneurysm is detected or suspected on non-invasive studies. The progressive enlargement of the ACoA after carotid occlusion, as described in our case 1, must be considered a radiological finding of risk for ''de novo'' aneurysm formation. (orig.)

  5. Sequential Hybrid Repair of Aorta and Bilateral Common Iliac Arteries Secondary to Chronic Aortic Dissection with Extensive Aneurysmal Degeneration in a Marfan Patient.

    Science.gov (United States)

    Hinojosa, Carlos A; Anaya-Ayala, Javier E; Laparra-Escareno, Hugo; Lizola, Rene; Torres-Machorro, Adriana

    2017-09-01

    Marfan syndrome is a connective tissue disorder associated with aortic dissection, aneurysmal degeneration and rupture. These cardiovascular complications represent the main cause of mortality, therefore repair is indicated. We present a 35-year-old woman who experienced acute onset of chest pain. Her imaging revealed a chronic DeBakey type I dissection with aortic root dilation and descending thoracic aneurysmal degeneration. She underwent a Bentall procedure and endovascular exclusion of the descending thoracic aortic aneurysm. She was closely followed and 2 years later a computed tomography angiography (CTA) revealed the aneurysmal degeneration of the thoracoabominal aorta and bilateral iliac arteries. The patient underwent a composite reconstruction using multi-visceral branched and bifurcated Dacron grafts. At 5 years from her last surgery, a CTA revealed no new dissection or further aneurysmal degenerations. Aortic disease in Marfan patients is a complex clinical problem that may lead to secondary or tertiary aortic reconstructions; close follow-up is mandatory.

  6. Use of the stereoscopic virtual reality display system for the detection and characterization of intracranial aneurysms: A Icomparison with conventional computed tomography workstation and 3D rotational angiography.

    Science.gov (United States)

    Liu, Xiujuan; Tao, Haiquan; Xiao, Xigang; Guo, Binbin; Xu, Shangcai; Sun, Na; Li, Maotong; Xie, Li; Wu, Changjun

    2018-07-01

    This study aimed to compare the diagnostic performance of the stereoscopic virtual reality display system with the conventional computed tomography (CT) workstation and three-dimensional rotational angiography (3DRA) for intracranial aneurysm detection and characterization, with a focus on small aneurysms and those near the bone. First, 42 patients with suspected intracranial aneurysms underwent both 256-row CT angiography (CTA) and 3DRA. Volume rendering (VR) images were captured using the conventional CT workstation. Next, VR images were transferred to the stereoscopic virtual reality display system. Two radiologists independently assessed the results that were obtained using the conventional CT workstation and stereoscopic virtual reality display system. The 3DRA results were considered as the ultimate reference standard. Based on 3DRA images, 38 aneurysms were confirmed in 42 patients. Two cases were misdiagnosed and 1 was missed when the traditional CT workstation was used. The sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), and accuracy of the conventional CT workstation were 94.7%, 85.7%, 97.3%, 75%, and99.3%, respectively, on a per-aneurysm basis. The stereoscopic virtual reality display system missed a case. The sensitivity, specificity, PPV, NPV, and accuracy of the stereoscopic virtual reality display system were 100%, 85.7%, 97.4%, 100%, and 97.8%, respectively. No difference was observed in the accuracy of the traditional CT workstation, stereoscopic virtual reality display system, and 3DRA in detecting aneurysms. The stereoscopic virtual reality display system has some advantages in detecting small aneurysms and those near the bone. The virtual reality stereoscopic vision obtained through the system was found as a useful tool in intracranial aneurysm diagnosis and pre-operative 3D imaging. Copyright © 2018 Elsevier B.V. All rights reserved.

  7. Right hepatic artery aneurysm.

    Science.gov (United States)

    Bernal, Astrid Del Pilar Ardila; Loures, Paulo; Calle, Juan Cristóbal Ospina; Cunha, Beatriz; Córdoba, Juan Camilo

    2016-01-01

    We report a case of an aneurysm of the right hepatic artery and its multidisciplinary management by general surgery, endoscopy and radiology services. Being a case of extremely low incidence, it is important to show its diagnostic and therapeutic approach. RESUMO Relatamos um caso de aneurisma da artéria hepática direita conduzido de forma multidisciplinar pelos Serviços de Cirurgia Geral, Endoscopia e Radiologia. Em se tratando de caso de incidência baixíssima, é importante mostrar o enfoque diagnóstico e terapêutico usado em seu manejo.

  8. Infected aortic aneurysm presenting as prevertebral abscess in magnetic resonance imaging: A case report

    International Nuclear Information System (INIS)

    Yu, Jung Re; Ko, Seong Joo; Heo, Sang Taek; Kim, Jin Seok; Kim, Seung Hyoung

    2013-01-01

    The differential diagnosis of mass-like lesions around the aorta includes saccular pseudoaneurysms and abscesses. A 69-year-old female was admitted with multiple abscesses and fluid collections in several muscles and joints. Methicillin susceptible Staphylococcus aureus was isolated from her blood and pus. Even though she was treated with repeated operations and appropriate antibiotics, her conditions worsened with persistent fever and newly developed abscesses at other sites. Serial enhanced computed tomography (CT) revealed a newly developed saccular abdominal aortic aneurysm in the retroaortic space at the celiac axis level. However, the infected aortic aneurysm mimicked a prevertebral abscess on enhanced spinal magnetic resonance imaging (MRI) due to its heterogeneous signal intensity caused by intraaneurysmal turbulent blood flow. We report to alert the pitfall in the diagnosis of saccular aortic aneurysm using spinal MRI and the importance of serial enhanced CT study in highly suspicious patients.

  9. Primary extracranial vertebral artery aneurysms.

    Science.gov (United States)

    Morasch, Mark D; Phade, Sachin V; Naughton, Peter; Garcia-Toca, Manuel; Escobar, Guillermo; Berguer, Ramon

    2013-05-01

    Extracranial vertebral artery aneurysms are uncommon and are usually associated with trauma or dissection. Primary cervical vertebral aneurysms are even rarer and are not well described. The presentation and natural history are unknown and operative management can be difficult. Accessing aneurysms at the skull base can be difficult and, because the frail arteries are often afflicted with connective tissue abnormalities, direct repair can be particularly challenging. We describe the presentation and surgical management of patients with primary extracranial vertebral artery aneurysms. In this study we performed a retrospective, multi-institutional review of patients with primary aneurysms within the extracranial vertebral artery. Between January 2000 and January 2011, 7 patients, aged 12-56 years, were noted to have 9 primary extracranial vertebral artery aneurysms. All had underlying connective tissue or another hereditary disorder, including Ehler-Danlos syndrome (n=3), Marfan's disease (n=2), neurofibromatosis (n=1), and an unspecified connective tissue abnormality (n=1). Eight of 9 aneurysms were managed operatively, including an attempted bypass that ultimately required vertebral ligation; the contralateral aneurysm on this patient has not been treated. Open interventions included vertebral bypass with vein, external carotid autograft, and vertebral transposition to the internal carotid artery. Special techniques were used for handling the anastomoses in patients with Ehler-Danlos syndrome. Although endovascular exclusion was not performed in isolation, 2 hybrid procedures were performed. There were no instances of perioperative stroke or death. Primary extracranial vertebral artery aneurysms are rare and occur in patients with hereditary disorders. Operative intervention is warranted in symptomatic patients. Exclusion and reconstruction may be performed with open and hybrid techniques with low morbidity and mortality. Copyright © 2013 Elsevier Inc. All rights

  10. Indocyanine Green Videoangiography for Surgery of a Ruptured Dissecting Aneurysm in the Precommunicating Anterior Cerebral Artery: A Technical Case Report.

    Science.gov (United States)

    Nagai, Yasunori; Goto, Masanori; Toda, Hiroki; Nishida, Namiko; Yoshimoto, Naoya; Iwasaki, Koichi

    2017-08-01

    Indocyanine green videoangiography (ICG-VA) is an important intraoperative adjunct for saccular aneurysm surgery, but its efficacy in surgery for dissecting aneurysms has rarely been reported. The authors describe the usefulness of preclipping ICG-VA in a rare case of a ruptured dissecting aneurysm located at the precommunicating (A1) segment of the anterior cerebral artery. A 52-year-old woman, with no history of connective tissue diseases or vascular disorders, presented with sudden headache and convulsion. The CT scan showed that the patient had subarachnoid hemorrhage. Angiography showed a dissecting aneurysm in the left A1 segment of the anterior cerebral artery. Thus, the patient underwent trapping of the dissecting aneurysm. ICG-VA was used as an intraoperative adjunct before and after clipping. The preclipping ICG-VA showed the heterogeneously bright dissecting aneurysm and branching arteries even in the presence of hematoma. Preclipping ICG-VA may enhance the advantage of direct surgery for dissecting aneurysm by allowing visualization of the extent of the dissected vascular wall and the related branching arteries. ICG-VA can be an indispensable adjunct to minimize the compromise from the surgical treatment for intracranial dissecting aneurysms. Copyright © 2017 by the Congress of Neurological Surgeons