WorldWideScience

Sample records for graded compression ultrasonography

  1. Graded compression ultrasonography and computed tomography in acute colonic diverticulitis: Meta-analysis of test accuracy

    International Nuclear Information System (INIS)

    Lameris, Wytze; Randen, Adrienne van; Bipat, Shandra; Stoker, Jaap; Bossuyt, Patrick M.M.; Boermeester, Marja A.

    2008-01-01

    The purpose was to investigate the diagnostic accuracy of graded compression ultrasonography (US) and computed tomography (CT) in diagnosing acute colonic diverticulitis (ACD) in suspected patients. We performed a systematic review and meta-analysis of the accuracy of CT and US in diagnosing ACD. Study quality was assessed with the QUADAS tool. Summary estimates of sensitivity and specificity were calculated using a bivariate random effects model. Six US studies evaluated 630 patients, and eight CT studies evaluated 684 patients. Overall, their quality was moderate. We did not identify meaningful sources of heterogeneity in the study results. Summary sensitivity estimates were 92% (95% CI: 80%-97%) for US versus 94% (95%CI: 87%-97%) for CT (p = 0.65). Summary specificity estimates were 90% (95%CI: 82%-95%) for US versus 99% (95%CI: 90%-100%) for CT (p = 0.07). For the identification of alternative diseases sensitivity ranged between 33% and 78% for US and between 50% and 100% for CT. The currently best available evidence shows no statistically significant difference in accuracy of US and CT in diagnosing ACD. Therefore, both US and CT can be used as initial diagnostic tool until new evidence is brought forward. However, CT is more likely to identify alternative diseases. (orig.)

  2. Compression ultrasonography of the lower extremity with portable vascular ultrasonography can accurately detect deep venous thrombosis in the emergency department.

    Science.gov (United States)

    Crisp, Jonathan G; Lovato, Luis M; Jang, Timothy B

    2010-12-01

    Compression ultrasonography of the lower extremity is an established method of detecting proximal lower extremity deep venous thrombosis when performed by a certified operator in a vascular laboratory. Our objective is to determine the sensitivity and specificity of bedside 2-point compression ultrasonography performed in the emergency department (ED) with portable vascular ultrasonography for the detection of proximal lower extremity deep venous thrombosis. We did this by directly comparing emergency physician-performed ultrasonography to lower extremity duplex ultrasonography performed by the Department of Radiology. This was a prospective, cross-sectional study and diagnostic test assessment of a convenience sample of ED patients with a suspected lower extremity deep venous thrombosis, conducted at a single-center, urban, academic ED. All physicians had a 10-minute training session before enrolling patients. ED compression ultrasonography occurred before Department of Radiology ultrasonography and involved identification of 2 specific points: the common femoral and popliteal vessels, with subsequent compression of the common femoral and popliteal veins. The study result was considered positive for proximal lower extremity deep venous thrombosis if either vein was incompressible or a thrombus was visualized. Sensitivity and specificity were calculated with the final radiologist interpretation of the Department of Radiology ultrasonography as the criterion standard. A total of 47 physicians performed 199 2-point compression ultrasonographic examinations in the ED. Median number of examinations per physician was 2 (range 1 to 29 examinations; interquartile range 1 to 5 examinations). There were 45 proximal lower extremity deep venous thromboses observed on Department of Radiology evaluation, all correctly identified by ED 2-point compression ultrasonography. The 153 patients without proximal lower extremity deep venous thrombosis all had a negative ED compression

  3. [Low grade renal trauma (Part II): diagnostic validity of ultrasonography].

    Science.gov (United States)

    Grill, R; Báca, V; Otcenásek, M; Zátura, F

    2010-04-01

    The aim of the study was to verify whether ultrasonography can be considered a reliable method for the diagnosis of low-grade renal trauma. The group investigated included patients with grade I or grade II blunt renal trauma, as classified by the AAST grading system, in whom ultrasonography alone or in conjunction with computed tomography was used as a primary diagnostic method. B-mode ultrasound with a transabdominal probe working at frequencies of 2.5 to 5.0 MHz was used. Every finding of post-traumatic changes in the renal tissues, i.e., post-contusion hypotonic infiltration of the renal parenchyma or subcapsular haematoma, was included. The results were statistically evaluated by the Chi-square test with the level of significance set at 5%, using Epi Info Version 6 CZ software. The group comprised 112 patients (43 women, 69 men) aged between 17 and 82 years (average, 38 years). It was possible to diagnose grade I or grade II renal injury by ultrasonography in only 60 (54%) of them. The statistical significance of ultrasonography as the only imaging method for the diagnosis of low-grade renal injury was not confirmed (p=0.543) Low-grade renal trauma is a problem from the diagnostic point of view. It usually does not require revision surgery and, if found during repeat surgery for more serious injury of another organ, it usually does not receive attention. Therefore, the macroscopic presentation of grade I and grade II renal injury is poorly understood, nor are their microscopic findings known, because during revision surgery these the traumatised kidneys are not usually removed and their injuries at autopsy on the patients who died of multiple trauma are not recorded either. The results of this study demonstrated that the validity of ultrasonography for the diagnosis of low-grade renal injury is not significant, because this examination can reveal only some of the renal injuries such as perirenal haematoma. An injury to the renal parenchyma is also indicated by

  4. EFFECTIVENESS OF ADJUVANT USE OF POSTERIOR MANUAL COMPRESSION WITH GRADED COMPRESSION IN THE SONOGRAPHIC DIAGNOSIS OF ACUTE APPENDICITIS

    Directory of Open Access Journals (Sweden)

    Senthilnathan V

    2018-01-01

    Full Text Available BACKGROUND Diagnosing appendicitis by Graded Compression Ultrasonogram is a difficult task because of limiting factors such as operator– dependent technique, retrocaecal location of the appendix and patient obesity. Posterior manual compression technique visualizes the appendix better in the Grey-scale Ultrasonogram. The Aim of this study is to determine the accuracy of ultrasound in detecting or excluding acute appendicitis and to evaluate the usefulness of the adjuvant use of posterior manual compression technique in visualization of the appendix and in the diagnosis of acute appendicitis MATERIALS AND METHODS This prospective study involved a total of 240 patients in all age groups and both sexes. All these patients underwent USG for suspected appendicitis. Ultrasonography was performed with transverse and longitudinal graded compression sonography. If the appendix is not visualized on graded compression sonography, posterior manual compression technique was used to further improve the detection of appendix. RESULTS The vermiform appendix was visualized in 185 patients (77.1% out of 240 patients with graded compression alone. 55 out of 240 patients whose appendix could not be visualized by graded compression alone were subjected to both graded followed by posterior manual compression technique among that Appendix was visualized in 43 patients on posterior manual compression technique amounting to 78.2% of cases, Appendix could not be visualized in the remaining 12 patients (21.8% out of 55. CONCLUSION Combined method of graded compression with posterior manual compression technique is better than the graded compression technique alone in diagnostic accuracy and detection rate of the vermiform appendix.

  5. Compressive properties of sandwiches with functionally graded

    Indian Academy of Sciences (India)

    The compressive behaviour of a new class of sandwich composite made up of jute fiber reinforced epoxy skins and piece-wise linear fly ash reinforced functionally graded (FG) rubber core is investigated in flat-wise mode. FG samples are prepared using conventional casting technique. Presence of gradation is quantified ...

  6. Diagnosis of thromboembolic disease: combined ventilation perfusion lung scan and compression ultrasonography

    International Nuclear Information System (INIS)

    Dadparvar, S.; Woods, K.; Magno, R.M.; Sabatino, J. C.; Patil, S.; Dou, Y.

    2002-01-01

    The clinical management of pulmonary embolism and deep venous thrombosis of the legs are similar and require prolonged anticoagulation therapy. The standard diagnostic approach in patients suspected of pulmonary embolism is ventilation-perfusion (V/Q) lung scan and compression ultrasonography to detect deep venous thrombosis. This retrospective study analyzed the role of V Q lung scan and compression ultrasonography in detection of thromboembolic disease. One hundred-twenty consecutive patients (65 female, 55 male) age range 18-95 (mean age 60.7) suspected for pulmonary embolism underwent concomitant V/Q lung scan and compression ultrasonography of the lower extremities. The clinical and radiographic correlation was performed. Of patients with non-diagnostic (low or intermediate probability ) lung scans, 15.4 % (14/91) received anticoagulation therapy for pulmonary embolism. This patients had either high pre-clinical suspicion for PE or underwent pulmonary arterio gram. However, there was an additional 7 % (7/91) increase in the number of patients who received anticoagulation therapy based on the results of ultrasound with confidence interval (3 %-16 %). We conclude that V/Q lung scan is a more sensitive examination for thromboembolic disease, and has a high negative predictive value. Ultrasonography of lower extremities demonstrated higher specificity and positive value. Among patients with non-diagnostic lung scan, the detection rate of thromboembolic disease is improved with addition of ultrasound

  7. Acute appendicitis: Meta-analysis of diagnostic performance of CT and graded compression US related to prevalence of disease

    NARCIS (Netherlands)

    van Randen, Adrienne; Bipat, Shandra; Zwinderman, Aeilko H.; Ubbink, Dirk T.; Stoker, Jaap; Boermeester, Marja A.

    2008-01-01

    Purpose: This study was a head-to-head comparison of graded compression ultrasonography (US) and computed tomography (CT) in helping diagnose acute appendicitis with an emphasis on diagnostic value at different disease prevalences, commonly occurring in various hospital settings. Materials and

  8. The value of ultrasonography combined with compression technique in differentiation between benign and malignant breast masses

    International Nuclear Information System (INIS)

    Yoon, Seong Kuk; Lee, Ki Nam; Nam, Kyung Jin; Jung, Won Jung

    2001-01-01

    To determine whether the compression technique is a valuable additional method for differentiating between benign and malignant breast masses. The ultrasonographic findings of 95 benign and 53 malignant masses, all pathologically proven, were prospectively analyzed with regard to five diagnostic criteria: shape (regular/irregular), retrotumoral acoustic phenomena (posterior enhancement/posterior attenuation), internal echo pattern (homogeneous/inhomogeneous), compression effect on shape (distortion/no change), and compression effect on internal echo pattern (more homogeneous/no change). The number of cases of benign and malignant masses, respectively, was as follows: regular/irregular shape: 84/11, 9/44; posterior acoustic enhancement/posterior attenuation: 82/13, 16/37; homogeneous/inhomogeneous internal echo pattern: 78/17, 14/39; distortion/no change in shape: 76/19, 5/48; and more homogeneous/no change in internal echo pattern: 71/24, 3/50. For all diagnostic criteria for the differentiation of benign and malignant masses, the differences were statistically significant (p<.05). Ultrasonography is helpful for differentiating between benign and malignant breast masses. The compression technique is a valuable additional diagnostic method

  9. Use of Bedside Compression Ultrasonography for Diagnosis of Deep Venous Thrombosis

    Directory of Open Access Journals (Sweden)

    Mohamad Moussa

    2017-07-01

    Full Text Available History of present illness: A 70-year-old female with a history of breast cancer and smoking for 50 years presented to the emergency department with left-lower extremity pain and swelling for two days. The patient denied recent long-distance travel, history of hypercoagulable disorder, or recent surgery. Physical examination revealed a warm, erythematous, 3+ edematous left-lower extremity with mild tenderness extending into the proximal thigh. Her D-dimer level was 2307ng/mL and vital signs were significant for a heart rate of 110bpm, oxygen saturation of 90% on 2 liters of oxygen, and blood pressure of 153/102. Significant findings: As shown in the still image of the performed ultrasound, a transverse view of the proximal-thigh revealed a visible thrombus (green shading occluding the lumen of the left common femoral vein (blue ring, which was non-compressible when direct pressure was applied to the probe. Also visible is a patent and compressible branch of the common femoral vein (purple ring and the femoral artery (red ring, highlighted by its thick vessel wall and pulsatile motion. Discussion: Deep venous thrombosis (DVT affects 1 per 1,000 individuals each year and may lead to complications such as recurrent DVT, pulmonary embolism, and death.1 The utilization of bedside compression ultrasonography allows for rapid diagnosis of DVT and has virtually replaced other diagnostic methods due to its non-invasive and inexpensive nature. When performing compression ultrasonography, the patient should be positioned to maximize distention of the leg veins. The extremity in question should be flexed at the knee and externally rotated at the hip (this fully exposes of the common, superficial, and deep femoral veins as well as the popliteal fossa and the head of the bed elevated at a 30-45 degree angle.2 In patients with an elevated D-dimer and low-to-moderate clinical probability, negative compression imaging of a single proximal location of the femoral

  10. Isolated Deep Venous Thrombosis: Implications for 2-Point Compression Ultrasonography of the Lower Extremity.

    Science.gov (United States)

    Adhikari, Srikar; Zeger, Wes; Thom, Christopher; Fields, J Matthew

    2015-09-01

    Two-point compression ultrasonography focuses on the evaluation of common femoral and popliteal veins for complete compressibility. The presence of isolated thrombi in proximal veins other than the common femoral and popliteal veins should prompt modification of 2-point compression technique. The objective of this study is to determine the prevalence and distribution of deep venous thrombi isolated to lower-extremity veins other than the common femoral and popliteal veins in emergency department (ED) patients with clinically suspected deep venous thrombosis. This was a retrospective study of all adult ED patients who received a lower-extremity venous duplex ultrasonographic examination for evaluation of deep venous thrombosis during a 6-year period. The ultrasonographic protocol included B-mode, color-flow, and spectral Doppler scanning of the common femoral, femoral, deep femoral, popliteal, and calf veins. Deep venous thrombosis was detected in 362 of 2,451 patients (14.7%; 95% confidence interval [CI] 13.3% to 16.1%). Thrombus confined to the common femoral vein alone was found in 5 of 362 cases (1.4%; 95% CI 0.2% to 2.6%). Isolated femoral vein thrombus was identified in 20 of 362 patients (5.5%; 95% CI 3.2% to 7.9%). Isolated deep femoral vein thrombus was found in 3 of 362 cases (0.8%; 95% CI -0.1% to 1.8%). Thrombus in the popliteal vein alone was identified in 53 of 362 cases (14.6%; 95% CI 11% to 18.2%). In our study, 6.3% of ED patients with suspected deep venous thrombosis had isolated thrombi in proximal veins other than common femoral and popliteal veins. Our study results support the addition of femoral and deep femoral vein evaluation to standard compression ultrasonography of the common femoral and popliteal vein, assuming that this does not have a deleterious effect on specificity. Copyright © 2014 American College of Emergency Physicians. Published by Elsevier Inc. All rights reserved.

  11. Compressive properties of sandwiches with functionally graded ...

    Indian Academy of Sciences (India)

    319–328. c Indian Academy of Sciences. Compressive properties ... †Mechanical Engineering, National Institute of Technology Karnataka, Surathkal, India .... spheres) which might aid in building FG composites is not explored ... Sample code.

  12. Ultrasonography versus magnetic resonance imaging in detecting and grading common extensor tendon tear in chronic lateral epicondylitis.

    Directory of Open Access Journals (Sweden)

    Artur Bachta

    Full Text Available To investigate the diagnostic performance and reliability of ultrasonography (US in detecting and grading common extensor tendon (CET tear in patients with chronic lateral epicondylitis (LE, using magnetic resonance imaging (MRI as the reference standard.The study comprised fifty-eight chronic LE patients. Each patient underwent US and MRI. CET status was classified as: high-grade tear (≥50% thickness, low-grade tear (<50% thickness, suspected tear (possible but not evident tear, no tear. Additionally, the following dichotomous scale was used: confirmed or unconfirmed CET tear. Relative US parameters (versus MRI for detecting CET tear included: sensitivity, specificity, positive predictive value (PPV, negative predictive value (NPV and accuracy. The agreement between US and MRI findings was measured using the weighted Cohen kappa coefficient (κ.US showed moderate agreement with MRI in detecting and grading CET tear (κ = 0.49. Sensitivity, specificity, and accuracy in CET tear detecting by US were 64.52%, 85.19%, and 72.73%, respectively. PPV and NPV of US were 83.33% and 67.65%, respectively. No patient with unconfirmed CET tear on US had high-grade CET tear on MRI.Ultrasonography is a valuable imaging modality that can be used as a screening tool to exclude high-grade CET tear in chronic LE patients. Once a tear is evident on US, MRI should be considered to assess precisely the extent of tendon injury.

  13. Stress Distribution in Graded Cellular Materials Under Dynamic Compression

    Directory of Open Access Journals (Sweden)

    Peng Wang

    Full Text Available Abstract Dynamic compression behaviors of density-homogeneous and density-graded irregular honeycombs are investigated using cell-based finite element models under a constant-velocity impact scenario. A method based on the cross-sectional engineering stress is developed to obtain the one-dimensional stress distribution along the loading direction in a cellular specimen. The cross-sectional engineering stress is contributed by two parts: the node-transitive stress and the contact-induced stress, which are caused by the nodal force and the contact of cell walls, respectively. It is found that the contact-induced stress is dominant for the significantly enhanced stress behind the shock front. The stress enhancement and the compaction wave propagation can be observed through the stress distributions in honeycombs under high-velocity compression. The single and double compaction wave modes are observed directly from the stress distributions. Theoretical analysis of the compaction wave propagation in the density-graded honeycombs based on the R-PH (rigid-plastic hardening idealization is carried out and verified by the numerical simulations. It is found that stress distribution in cellular materials and the compaction wave propagation characteristics under dynamic compression can be approximately predicted by the R-PH shock model.

  14. Comparison of gray-scale contrast-enhanced ultrasonography with contrast-enhanced computed tomography in different grading of blunt hepatic and splenic trauma: an animal experiment.

    Science.gov (United States)

    Tang, Jie; Li, Wenxiu; Lv, Faqin; Zhang, Huiqin; Zhang, Lihai; Wang, Yuexiang; Li, Junlai; Yang, Li

    2009-04-01

    To compare the diagnostic value of contrast-enhanced ultrasonography (CEUS) with contrast-enhanced computed tomography (CECT) for the detection of different grading of solid organ injuries in blunt abdominal trauma in animals. A self-made miniature tools were used as models to simulate a blunt hepatic or splenic trauma in 16 and 14 anesthetized dogs, respectively. Baseline ultrasound, CEUS and CECT were used to detect traumatic injuries of livers and spleens. The degree of injuries was determined by CEUS according to the American Association for the Surgery of Trauma (AAST) scale and the results compared with injury scale based on CECT evaluation. CEUS showed 22 hepatic injury sites in 16 animals and 17 splenic injury sites in other 14 animals. According to AAST scale, 2 grade I, 4 grade II, 3 grade III, 5 grade IV and 2 grade V hepatic lesions were present in 16 animals; 2 grade I, 4 grade II, 6 grade III and 2 grade IV splenic lesions in 14 animals. On CECT scan, 21 hepatic and 17 splenic injuries were demonstrated. According to Becker CT scaling for hepatic injury, 1 grade I, 2 grade II, 4 grade III, 5 grade IV and 2 grade V hepatic injuries were present. On the basis of Buntain spleen scaling, 2 grade I, 5 grade II, 5 grade III, 2 grade IV splenic injuries were showed. After Spearman rank correlation analysis, the agreement of CEUS with CECT on the degree of hepatic and splenic injury is 93.3% and 92.9%, respectively. CT is currently considered as the reference method for grading blunt abdominal trauma, according to experiment results, CEUS grading showed high levels of concordance with CECT. CEUS can accurately determine the degree of injury and will play an important role in clinical application.

  15. Comparison of helical computed tomography and ultrasonography in diagnosis of acute appendicitis

    International Nuclear Information System (INIS)

    Nafees, M.; Abbas, G.; Sarwar, S.

    2010-01-01

    The objective of study is to compare the diagnostic accuracy of helical computed tomography and ultrasonography in acute appendicitis using histopathology as gold standard. Thirty cases of clinically suspected acute appendicitis were included in the study selected on non probability convenience sampling technique. Computed tomography and graded compression ultrasonography of right lower quadrant of abdomen were conducted and results compared with histopathological findings. Amongst 30 patients who underwent computed tomography and graded compression ultrasonography examinations of right lower quadrant for diagnosis of acute appendicitis, on computed tomography 19 were diagnosed with acute appendicitis, 10 were diagnosed as not having the disease and 01 patient diagnosed as not having appendicitis on computed tomography did not improve clinically, was operated upon and histopathology proved it as acute appendicitis. While on graded compression ultrasonography 15 were diagnosed with acute appendicitis, 11 were diagnosed as not having the disease and 04 patients diagnosed as not having appendicitis on ultrasonography, did not improve clinically, were operated upon and histopathology proved it as acute appendicitis. This showed that CT scan has sensitivity of 95%, specificity 100%, positive predictive value 100%, negative predictive value 90.91% and overall accuracy of 96.67% while ultrasonography has sensitivity of 78.9%, specificity 100%, positive predictive value 100%, negative predictive value 73.33% and overall accuracy of 86.67%. We concluded that Helical computed tomography is highly accurate in diagnosing acute appendicitis as compared to ultrasonography and it helps to reduce negative appendectomy rate. (author)

  16. Artificial neural network aided non-invasive grading evaluation of hepatic fibrosis by duplex ultrasonography

    Directory of Open Access Journals (Sweden)

    Zhang Li

    2012-06-01

    Full Text Available Abstract Background Artificial neural networks (ANNs are widely studied for evaluating diseases. This paper discusses the intelligence mode of an ANN in grading the diagnosis of liver fibrosis by duplex ultrasonogaphy. Methods 239 patients who were confirmed as having liver fibrosis or cirrhosis by ultrasound guided liver biopsy were investigated in this study. We quantified ultrasonographic parameters as significant parameters using a data optimization procedure applied to an ANN. 179 patients were typed at random as the training group; 60 additional patients were consequently enrolled as the validating group. Performance of the ANN was evaluated according to accuracy, sensitivity, specificity, Youden’s index and receiver operating characteristic (ROC analysis. Results 5 ultrasonographic parameters; i.e., the liver parenchyma, thickness of spleen, hepatic vein (HV waveform, hepatic artery pulsatile index (HAPI and HV damping index (HVDI, were enrolled as the input neurons in the ANN model. The sensitivity, specificity and accuracy of the ANN model for quantitative diagnosis of liver fibrosis were 95.0%, 85.0% and 88.3%, respectively. The Youden’s index (YI was 0.80. Conclusions The established ANN model had good sensitivity and specificity in quantitative diagnosis of hepatic fibrosis or liver cirrhosis. Our study suggests that the ANN model based on duplex ultrasound may help non-invasive grading diagnosis of liver fibrosis in clinical practice.

  17. How should we grade lumbar disc herniation and nerve root compression? A systematic review.

    Science.gov (United States)

    Li, Yiping; Fredrickson, Vance; Resnick, Daniel K

    2015-06-01

    MRI is the gold standard for evaluating the relationship of disc material to soft tissue and neural structures. However, terminologies used to describe lumbar disc herniation and nerve root compression have always been a source of confusion. A clear understanding of lumbar disc terminology among clinicians, radiologists, and researchers is vital for patient care and future research. Through a systematic review of the literature, the purpose of this article is to describe lumbar disc terminology and comment on the reliability of various nomenclature systems and their application to clinical practice. PubMed was used for our literature search using the following MeSH headings: "Magnetic Resonance Imaging and Intervertebral Disc Displacement" and "Lumbar Vertebrae" and terms "nomenclature" or "grading" or "classification". Ten papers evaluating lumbar disc herniation/nerve root compression using different grading criteria and providing information regarding intraobserver and interobserver agreement were identified. To date, the Combined Task Force (CTF) and van Rijn classification systems are the most reliable methods for describing lumbar disc herniation and nerve root compression, respectively. van Rijn dichotomized nerve roots from "definitely no root compression, possibly no root compression, indeterminate root compression, possible root compression, and definite root compression" into no root compression (first three categories) and root compression (last two categories). The CTF classification defines lumbar discs as normal, focal protrusion, broad-based protrusion, or extrusion. The CTF classification system excludes "disc bulges," which is a source of confusion and disagreement among many practitioners. This potentially accounts for its improved reliability compared with other proposed nomenclature systems. The main issue in the management of patients with lumbar disc disease and nerve root compression is correlation of imaging findings with clinical

  18. Clinical utility of real-time compression ultrasonography for diagnostic management of patients with recurrent venous thrombosis

    NARCIS (Netherlands)

    Heijboer, H.; Jongbloets, L. M.; Büller, H. R.; Lensing, A. W.; ten Cate, J. W.

    1992-01-01

    In the diagnostic management of patients with clinically suspected recurrent deep-vein thrombosis (DVT), there are potential limitations to all available diagnostic techniques. Since venous abnormalities may persist for some time after an acute thrombosis, the usefulness of compression

  19. Radiologic diagnosis of gastro-oesophageal reflux by means of graded abdominal compression

    Energy Technology Data Exchange (ETDEWEB)

    Fransson, S.G.; Soekjer, H.; Johansson, K.E.; Tibbling, L.

    The aim of the study was to ascertain whether abdominal compression by a standardized technique increases the reliability of the radiologic diagnosis of gastro-oesophageal reflux. Eighty-eight patients were examined by means of a manometric reflux test, 24-hour measurements of pH and endoscopy. The radiologic examination was performed with and without graded abdominal compression, the patient at the same time turning from side to side. When abdominal compression was included the result of the radiologic examination was positive in 31 patients. In the absence of abdominal compression reflux was detected in 11 of these patients. In one patient reflux was detected only without compression. All these 31 patients had one more test positive and in 27 at least 2 more tests were positive. Another 21 patients had reflux disease as indicated by at least 2 of the 3 other tests. The compression technique seems to yield no false positive responses, and proved to be significantly more reliable than examinations without compression.

  20. Effects of graded mechanical compression of rabbit sciatic nerve on nerve blood flow and electrophysiological properties.

    Science.gov (United States)

    Yayama, Takafumi; Kobayashi, Shigeru; Nakanishi, Yoshitaka; Uchida, Kenzo; Kokubo, Yasuo; Miyazaki, Tsuyoshi; Takeno, Kenichi; Awara, Kosuke; Mwaka, Erisa S; Iwamoto, Yukihide; Baba, Hisatoshi

    2010-04-01

    Entrapment neuropathy is a frequent clinical problem that can be caused by, among other factors, mechanical compression; however, exactly how a compressive force affects the peripheral nerves remains poorly understood. In this study, using a rabbit model of sciatic nerve injury (n=12), we evaluated the time-course of changes in intraneural blood flow, compound nerve action potentials, and functioning of the blood-nerve barrier during graded mechanical compression. Nerve injury was applied using a compressor equipped with a custom-made pressure transducer. Cessation of intraneural blood flow was noted at a mean compressive force of 0.457+/-0.022 N (+/-SEM), and the compound action potential became zero at 0.486+/-0.031 N. Marked extravasation of Evans blue albumin was noted after 20 min of intraneural ischemia. The functional changes induced by compression are likely due to intraneural edema, which could subsequently result in impairment of nerve function. These changes may be critical factors in the development of symptoms associated with nerve compression. (c) 2009 Elsevier Ltd. All rights reserved.

  1. The grade of vesicoureteral reflux in voiding cystourethrography: comparison with ultrasonography and Tc99m-DMSA renal scintigraphy

    International Nuclear Information System (INIS)

    1998-01-01

    To evaluate the prevalence of abnormalities seen on sonography and renal scintigraphy, according to the grade of vesicoureteral reflux (VUR) on in voiding cystourethrography(VCUG). One hundred and forty-nine patients (age range: 1 months-10 years) with urinary tract infection underwent sonography, VCUG, and renal scans, and 32 showed VUR on VCUG. We retrospectively evaluated the frequency and characteristic findings of sonographic abnormalities according to the grade of VUR, and also the frequency of cortical defects seen on renal scans of 32 patients with VUR. The remaining 117 patients without VUR were also evaluated for the frequency of abnormal findings seen on sonography and renal scans. Among 32 patients (49 kidneys) with VUR, abnormal findings were not detected in 17 (29 kidneys) on sonography; thus, findings were abnormal in 15 (20 kidneys, 41%). Among these 20 kidneys, renal calyceal and/or pelvic dilatation and dilatation of distal ureter were seen in 11, all of which were grade 4-5 VUR. Renal pelvic dilatation only was noted in eight kidneys; two were grade 1-3 and six were grade 4-5 VUR. Nineteen patients (24 kidneys, 49%) showed focal cortical defects on renal scintigraphy. Six kidneys were grade 1-3, and 18 kidneys were grade 4-5 VUR. Of 117 patients without VUR, 34 patients (29%) showed renal pelvic dilatation on sonography and in 14 patients (12%), cortical defects were seen on renal scintigraphy. Among 32 patients with VUR, 41% showed abnormal sonographic findings and in 49%, cortical defects were seen on renal scintigraphy. With a higher grade of VUR, the prevalence of abnormalities increased on both sonography and renal scintigraphy. Sonographic demonstration of renal caliceal and/or pelvic dilatation associated with ipsilateral distal ureteric dilatation was the characteristic finding in high grade VUR.=20

  2. Performance study on a low-temperature absorption–compression cascade refrigeration system driven by low-grade heat

    International Nuclear Information System (INIS)

    Xu, Yingjie; Chen, Guangming; Wang, Qin; Han, Xiaohong; Jiang, Ning; Deng, Shiming

    2016-01-01

    Highlights: • An absorption–compression system for low-temperature is developed and analyzed. • Cooling capacity, compression power, and discharge temperature are all improved. • At −170 °C, giving 200 W low-grade cooling capacity, COP increases by 28.6%. • Simulation results are verified experimentally, showing good agreement. - Abstract: This paper presents a performance study on a low-temperature absorption–compression cascade refrigeration system (LACRS), which consists of an absorption subsystem (AS) and a vapor compression auto-cascade subsystem (CS). In the system, low-grade heat of AS is used to subcool the CS, which can obtain cold energy at −170 °C. A simulation study is carried out to investigate the effects of evaporating temperature and low-grade cooling capacity on system performance. The study results show that as low-grade cooling capacity from the AS is provided to the CS, high-grade cooling capacity increases, compressor power consumption decreases, and the COP of the CS therefore increases. Comparing with compression auto-cascade cycle, the largest COP improvement of LACRS is about 38%. The model is verified by experimental data. An additional high-grade cooling capacity is obtained experimentally at −170 °C. The study results presented in this paper not only demonstrate the excellent performance of the LACRS, but also provide important guidance to further system design, and practical application.

  3. Compressive evaluation of homogeneous and graded epoxy-glass particulate composites.

    Science.gov (United States)

    Seaglar, J; Rousseau, C-E

    2015-04-01

    The propagation of stress waves in epoxy-glass particulate composites and graded materials was studied experimentally. Materials tested in this study consisted of an epoxy matrix with various concentrations of spherical glass particles having a mean diameter of 42μm. Plate impact experiments were performed using a gas gun. Embedded within the specimens were manganin stress gauges used to record propagating compressive longitudinal stress waves through the material. High strain rate experiments using a Split Hopkinson Pressure Bar (SHPB) apparatus were also performed to evaluate the dynamic strength of the specimens, while quasi-static compression tests were undertaken to characterize their quasi-static behavior. Ultrasonic wave speed measurements were carried-out in order to obtain additional material properties and characterize the gradation in functionally graded materials (FGM). It was found that low volume fractions of particles are detrimental to the performance of the material under impact loading, while concentrations in the range of about 30 to 45% by volume exhibit characteristics of higher degrees of scattering. This suggests that materials in this latter range would be more effective in the thwarting of destructive shock waves than the homogeneous matrix material. Impact testing of FGM specimens suggests that impact loading on the stiff (high volume fraction) face results in much higher levels of scattering. Therefore, such materials would be effective for use in light weight armor or as shielding materials due to their effective attenuation of mechanical impulses. Copyright © 2015 Elsevier B.V. All rights reserved.

  4. Effect of concrete strength gradation to the compressive strength of graded concrete, a numerical approach

    Science.gov (United States)

    Pratama, M. Mirza Abdillah; Aylie, Han; Gan, Buntara Sthenly; Umniati, B. Sri; Risdanareni, Puput; Fauziyah, Shifa

    2017-09-01

    Concrete casting, compacting method, and characteristic of the concrete material determine the performance of concrete as building element due to the material uniformity issue. Previous studies show that gradation in strength exists on building member by nature and negatively influence the load carrying capacity of the member. A pilot research had modeled the concrete gradation in strength with controllable variable and observed that the weakest material determines the strength of graded concrete through uniaxial compressive loading test. This research intends to confirm the recent finding by a numerical approach with extensive variables of strength disparity. The finite element analysis was conducted using the Strand7 nonlinear program. The results displayed that the increase of strength disparity in graded concrete models leads to the slight reduction of models strength. A substantial difference in displacement response is encountered on the models for the small disparity of concrete strength. However, the higher strength of concrete mix in the graded concrete models contributes to the rise of material stiffness that provides a beneficial purpose for serviceability of building members.

  5. Prevention of thromboembolism following elective hip surgery. The value of regional anesthesia and graded compression stockings

    DEFF Research Database (Denmark)

    Wille-Jørgensen, P; Christensen, S W; Bjerg-Nielsen, A

    1989-01-01

    Ninety-eight patients scheduled for elective hip arthroplasty receiving either general or regional anesthesia and graded compression stockings as the only thromboprophylactic treatment were screened for postoperative deep-venous thrombosis with 99mTc-plasmin scintimetry. The diagnosis of deep......-venous thrombosis was established by phlebography and the diagnosis of pulmonary embolism by pulmonary perfusion and ventilation scintigraphy. Of 65 patients surgically treated under general anesthesia, 20 (31%) developed deep-venous thrombosis and six developed pulmonary embolism. Of 33 patients surgically treated...... using regional anesthesia, three (9%) developed deep-venous thrombosis and one developed a pulmonary embolus. The number of patients developing deep-venous thrombosis was significantly lower in the group receiving regional anesthesia compared with the group receiving general anesthesia. The results...

  6. [Pancreatic ultrasonography].

    Science.gov (United States)

    Fernández-Rodríguez, T; Segura-Grau, A; Rodríguez-Lorenzo, A; Segura-Cabral, J M

    2015-04-01

    Despite the recent technological advances in imaging, abdominal ultrasonography continues to be the first diagnostic test indicated in patients with a suspicion of pancreatic disease, due to its safety, accessibility and low cost. It is an essential technique in the study of inflammatory processes, since it not only assesses changes in pancreatic parenchyma, but also gives an indication of the origin (bile or alcoholic). It is also essential in the detection and tracing of possible complications as well as being used as a guide in diagnostic and therapeutic punctures. It is also the first technique used in the study of pancreatic tumors, detecting them with a sensitivity of around 70% and a specificity of 90%. Copyright © 2014 Sociedad Española de Médicos de Atención Primaria (SEMERGEN). Publicado por Elsevier España. All rights reserved.

  7. Comparative evaluation of the powder and compression properties of various grades and brands of microcrystalline cellulose by multivariate methods.

    Science.gov (United States)

    Haware, Rahul V; Bauer-Brandl, Annette; Tho, Ingunn

    2010-01-01

    The present work challenges a newly developed approach to tablet formulation development by using chemically identical materials (grades and brands of microcrystalline cellulose). Tablet properties with respect to process and formulation parameters (e.g. compression speed, added lubricant and Emcompress fractions) were evaluated by 2(3)-factorial designs. Tablets of constant true volume were prepared on a compaction simulator at constant pressure (approx. 100 MPa). The highly repeatable and accurate force-displacement data obtained was evaluated by simple 'in-die' Heckel method and work descriptors. Relationships and interactions between formulation, process and tablet parameters were identified and quantified by multivariate analysis techniques; principal component analysis (PCA) and partial least square regressions (PLS). The method proved to be able to distinguish between different grades of MCC and even between two different brands of the same grade (Avicel PH 101 and Vivapur 101). One example of interaction was studied in more detail by mixed level design: The interaction effect of lubricant and Emcompress on elastic recovery of Avicel PH 102 was demonstrated to be complex and non-linear using the development tool under investigation.

  8. Emergency ultrasonography of the gastrointestinal tract of children

    Energy Technology Data Exchange (ETDEWEB)

    Hwang, Jae Yeon [Dept. of Radiology, Pusan National University Yangsan Hospital, Yangsan (Korea, Republic of)

    2017-07-15

    Ultrasonography (US) is widely used to evaluate most body parts in pediatric patients because it is simple, noninvasive, easy to use, and applicable in a wide variety of clinical situations. US is the modality of choice for the initial evaluation of acute abdominal pain in pediatric patients because of their small body habitus and the presence of less fat tissue in the abdominal wall and peritoneal cavity. The most important factor in performing pediatric emergency US is the graded compression technique and selection of the proper transducer. The careful evaluation of bowel wall thickening combined with ancillary findings such as fluid collection, increased echogenicity of the mesenteric fat tissue, enlarged lymph nodes, hyperemic bowel changes, and abnormal bowel peristalsis can increase the diagnostic capability of US.

  9. Emergency ultrasonography of the gastrointestinal tract of children

    International Nuclear Information System (INIS)

    Hwang, Jae Yeon

    2017-01-01

    Ultrasonography (US) is widely used to evaluate most body parts in pediatric patients because it is simple, noninvasive, easy to use, and applicable in a wide variety of clinical situations. US is the modality of choice for the initial evaluation of acute abdominal pain in pediatric patients because of their small body habitus and the presence of less fat tissue in the abdominal wall and peritoneal cavity. The most important factor in performing pediatric emergency US is the graded compression technique and selection of the proper transducer. The careful evaluation of bowel wall thickening combined with ancillary findings such as fluid collection, increased echogenicity of the mesenteric fat tissue, enlarged lymph nodes, hyperemic bowel changes, and abnormal bowel peristalsis can increase the diagnostic capability of US

  10. Ultrasonography of the shoulder: pitfalls and variants

    International Nuclear Information System (INIS)

    Friedman, L.; Finlay, K.; Popowich, T.; Jurriaans, E.

    2002-01-01

    Ultrasonography (US) of the shoulder, particularly the evaluation of the rotator cuff, is the most common examination of the musculoskeletal system performed in most practices. Despite this, it remains one of the most difficult examinations to learn. There are many pitfalls and errors that can occur initially, but once mastered, US of the rotator cuff is one of the best methods available for diagnosing rotator cuff disease. The literature reports a 91%-95% sensitivity and close to 90% specificity and accuracy in the assessment of both partial and full thickness tears. This compares favourably with magnetic resonance imaging (MRI), where a more recent study reported an 84% sensitivity, 97% specificity and an accuracy of 93% for combined partial and full thickness tears of the rotator cuff. Advantages of US include low cost, easy access, high degree of accuracy in expert hands, ease of comparison with the opposite side, dynamic real-time examination, ability to focus on the exact site of the patient's pain and graded compression availability. It is for these reasons that we hope to outline the various pitfalls and common errors that can occur during the examination in a systematic fashion. It must also be pointed out that computed tomographic arthrography and magnetic resonance arthrography remain the investigations of choice for assessing labral disorders. (author)

  11. Intramedullary nail versus dynamic compression plate fixation in treating humeral shaft fractures: grading the evidence through a meta-analysis.

    Directory of Open Access Journals (Sweden)

    JianXiong Ma

    Full Text Available There is a debate regarding the choice of operative intervention in humeral shaft fractures that require surgical intervention. The choices for operative interventions include intramedullary nailing (IMN and dynamic compression plate (DCP. This meta-analysis was performed to compare fracture union, functional outcomes, and complication rates in patients treated with IMN or DCP for humeral shaft fractures and to develop GRADE (Grading of Recommendations, Assessment, Development, and Evaluation-based recommendations for using the procedures to treat humeral shaft fractures. A systematic search of all the studies published through December 2012 was conducted using the Medline, Embase, Sciencedirect, OVID and Cochrane Central databases. The randomized controlled trials (RCTs and quasi-RCTs that compared IMN with DCP in treating adult patients with humeral shaft fractures and provided data regarding the safety and clinical effects were identified. The demographic characteristics, adverse events and clinical outcomes were manually extracted from all of the selected studies. Ten studies that included a total of 448 patients met the inclusion criteria. The results of a meta-analysis indicated that both IMN and DCP can achieve similar fracture union with a similar incidence of radial nerve injury and infection. IMN was associated with an increased risk of shoulder impingement, more restriction of shoulder movement, an increased risk of intraoperative fracture comminution, a higher incidence of implant failure, and an increased risk of re-operation. The overall GRADE system evidence quality was very low, which reduces our confidence in the recommendations of this system. DCP may be superior to IMN in the treatment of humeral shaft fractures. Because of the low quality evidence currently available, high-quality RCTs are required.

  12. Ultrasonography versus intravenous urography

    International Nuclear Information System (INIS)

    Aslaksen, A.

    1991-01-01

    The present study was performed to compare the clinical value of urography and ultrasonography in a non-selected group of patients referred for urography to a university hospital. The conslusions and clinical implications of the study are as follows: Intravenous urography remains the cornerstone imaging examination in the evaluation of ureteral calculi. Ultrasonography is a valuable adjunct in cases of non- visualization of the kidneys, in distal obstruction and known contrast media allergy. When women with recurrent urinary tract infection are referred for imaging of the urinary tract, ultrasonography should be used. Ultrasonography should replace urography for screening of non-acute hydronephrosis like in female genital cancer and benign prostate hyperplasia. There is good correlation between urography and ultrasonography in assessing the degree of hydronephrosis. However, more researh on the relationship between hydronephrosis and obstruction is necessary. Ultrasonography should be used as the only imaging method of the upper urinary tract in patients with microscopic hematuria. In patients less than 50 years with macroscopic hematuria, ultrasonography should be used as the only imaging of the upper urinary tract, and an examination of the urinary bladder should be included. In patients over 50 years, urography supplied with ultrasonography should be used, but more research is necessary on the subject of imaging method and age. 158 refs

  13. Ultrasonography for Proper Endotracheal Tube Placement Confirmation in Out-of-hospital Cardiac Arrest Patients: Two-center Experience

    Directory of Open Access Journals (Sweden)

    Jen-Tang Sun

    2014-06-01

    Conclusion: Real-time tracheal ultrasonography is an accurate method for identifying endotracheal tube position during cardiopulmonary resuscitation without the need for interruption of chest compression.

  14. Diagnostic nerve ultrasonography

    International Nuclear Information System (INIS)

    Baeumer, T.; Grimm, A.; Schelle, T.

    2017-01-01

    For the diagnostics of nerve lesions an imaging method is necessary to visualize peripheral nerves and their surrounding structures for an etiological classification. Clinical neurological and electrophysiological investigations provide functional information about nerve lesions. The information provided by a standard magnetic resonance imaging (MRI) examination is inadequate for peripheral nerve diagnostics; however, MRI neurography is suitable but on the other hand a resource and time-consuming method. Using ultrasonography for peripheral nerve diagnostics. With ultrasonography reliable diagnostics of entrapment neuropathies and traumatic nerve lesions are possible. The use of ultrasonography for neuropathies shows that a differentiation between different forms is possible. Nerve ultrasonography is an established diagnostic tool. In addition to the clinical examination and clinical electrophysiology, structural information can be obtained, which results in a clear improvement in the diagnostics. Ultrasonography has become an integral part of the diagnostic work-up of peripheral nerve lesions in neurophysiological departments. Nerve ultrasonography is recommended for the diagnostic work-up of peripheral nerve lesions in addition to clinical and electrophysiological investigations. It should be used in the clinical work-up of entrapment neuropathies, traumatic nerve lesions and spacy-occupying lesions of nerves. (orig.) [de

  15. Value of ultrasonography in the diagnosis of acute appendicitis

    International Nuclear Information System (INIS)

    Sohn, Seok Ho; Jung, Kun Sik; Kim, Jung Sik; Woo, Seong Ku; Chung, Ki Yong; Kim, Hee Jin

    1993-01-01

    During a 12-month period high-resolution, real-time ultrasonography (US) with graded compression was performed on 268 consecutive patients with clinically suspected acute appendicitis and its complications. US visualization of a fluid-filled, non-compressed appendix or a decompressed, thick-walled appendix was the primary criterion for a diagnosis of acute appendicitis. The sonographic findings were correlated with surgical-pathologic outcome in 92 cases and with the findings of clinical follow-ups in the remainder. US was found to be accurate in the diagnosis of acute appendicitis and its complication with a sensitivity of 93.3%, a specificity of 98.9%, and an accuracy of 97%. The predictive value of a positive test was 97.7%; that of a negative test was 96.7%. There were two false-positive examinations in patients with a thick-walled appendix or periapperdiceal abscess, which were surgically confirmed as appendiceal adenocarcinoma and perforated cecal diverticulitis respectively. There were six false-negative examinations in patients with a sonographically no-visible appendix, which were confirmed surgically as acute appendicitis (n=5) and perforated appendicitis (n=1). Our results show that high-resolution, real-time US is an accurate imaging modality in the diagnosis of acute appendicitis and the evaluation of its complications

  16. Ultrasonography in trauma

    DEFF Research Database (Denmark)

    Weile, Jesper; Nielsen, Klaus; Primdahl, Stine C

    2017-01-01

    BACKGROUND: The Focused Assessment with Sonography in Trauma (FAST) protocol is considered beneficial in emergent evaluation of trauma patients with blunt or penetrating injury and has become integrated into the Advanced Trauma Life Support (ATLS) protocol. No guidelines exist as to the use...... of ultrasonography in trauma in Denmark. We aimed to determine the current use of ultrasonography for assessing trauma patients in Denmark. METHODS: We conducted a nation-wide cross-sectional investigation of ultrasonography usage in trauma care. The first phase consisted of an Internet-based investigation....... Twenty-one (95.5%) of the guidelines included and recommended FAST as part of trauma assessment. The recommended person to perform the examination was the radiologist in n = 11 (50.0%), the surgeon in n = 6 (27.3%), the anesthesiologist in n = 1 (4.5%), and unspecified in n = 3 (13.6%) facilities. FAST...

  17. Ultrasonography of polycystic kidney

    International Nuclear Information System (INIS)

    Oh, Seung Chul; Cho, Seung Gi; Lee, Kwan Seh; Kim, Kun Sang

    1980-01-01

    Polycystic disease is defined as a heritable disorder with diffuse involvement of both kidneys. The term 'Polycystic disease' comprises at least two separate, genetically different disease-one with an onset typically in childhood (infantile polycystic disease) and the other with an onset typically in adulthood (adult polycystic disease). Adult polycystic kidney disease is the most common form of cystic kidney disease in humans. Ultrasonography is a very useful noninvasive diagnostic modality in the patient with clinically suspected renal diseases as well as screening test. 14 cases of ultrasonography in patient with polycystic kidney were reviewed. All cases show unilateral or bilateral enlarged kidneys. 7 cases reveal kidneys and liver replaced by multiple cysts of varing size. Screening ultrasonography for a familial tree is reported

  18. Ultrasonography of jaundice

    International Nuclear Information System (INIS)

    Cho, Byung Jae; Bae, Sang Hoon; Lee, Seung Ro; Kim, Chu Wan

    1980-01-01

    The importance of ultrasonography in the evaluation of jaundice is stressed with an analysis of 47 cases of jaundice. 31 cases proved to be obstructive and 16 non-obstructive jaundice. Obstructive jaundice could be differentiated from non-obstructive jaundice in all but 2 cases, (96%). The site of obstruction in 31 cases of obstructive jaundice could be predicted correctly in 23 cases of 31, (90%), and cause of obstruction with an accuracy of 35% as well. One can certainly recommend ultrasonography as an initial procedure of choice in jaundice patients

  19. Ultrasonography in abdominal emergencies

    International Nuclear Information System (INIS)

    Risi, D.; Alessi, G.; Meli, C.; Marzano, M.; Fiori, E.; Caterino, S.

    1989-01-01

    From February 1986 to March 1988 113 abdominal US exams were performed in emergency situation to evaluate the accuracy of this methodology: 13 were blunt traumas, 18 post-operative complications. A real-time scanner with a linear probe of 5 MHz was employed. The results were confirmed by surgical and/or clinical and instrumental evaluation. In 81% of the examinations, ultrasonography allowed a diagnosis to be made. Gallbladder and biliary pathologies were the most common findings. The results (sensibility 96%, specificity 88%, accuracy 95%) confirm the affidability of ultrasonography in abdominal emergencies, as shown in literature

  20. Endoscopic Ultrasonography in the Diagnosis of Gastric Subepithelial Lesions

    Directory of Open Access Journals (Sweden)

    Eun Jeong Gong

    2016-09-01

    Full Text Available Subepithelial lesions occasionally found in the stomach of patients undergoing endoscopy may be either benign lesions or tumors with malignant potential. They may also appear due to extrinsic compression. Discrimination of gastric subepithelial lesions begins with meticulous endoscopic examination for size, shape, color, mobility, consistency, and appearance of the overlying mucosa. Accurate diagnosis can be achieved with endoscopic ultrasonography, which provides useful information on the exact size, layer-of-origin, and characteristic morphologic features to support a definitive diagnosis. Endoscopic ultrasonography also aids in the prediction of malignant potential, especially in gastrointestinal stromal tumors. Features of subepithelial lesions identified on endoscopic ultrasonography can be used to determine whether further diagnostic procedures such as endoscopic resection, fine needle aspiration, or core biopsy are required. Endoscopic ultrasonography is a valuable tool for diagnosis and clinical decision making during follow-up of gastric subepithelial lesions.

  1. Ultrasonography X gamma radiography

    International Nuclear Information System (INIS)

    Mello Campos, A.M. de

    1989-01-01

    The accumulated experience in the last ten years of substitution to essays by gamma radiography to essay by ultrasonography, starting of the systematic comparison and tabulation of the results obtained by both essays applied in welding joints, in field, in steel pipelines of the SABESP. (V.R.B.)

  2. Surgeon-performed ultrasonography

    DEFF Research Database (Denmark)

    Todsen, Tobias

    2017-01-01

    Surgeons are increasingly using ultrasonography (US) in their clinical management of patients. However, US is a very user-dependent imaging modality and proper skills of the US operator are needed to ensure quality in patient care. This thesis explores the validity evidence for assessment...

  3. Ultrasonography of the Kidney

    DEFF Research Database (Denmark)

    Lindskov Hansen, Kristoffer; Nielsen, Michael Bachmann; Ewertsen, Caroline

    2016-01-01

    Ultrasonography of the kidneys is essential in the diagnosis and management of kidney-related diseases. The kidneys are easily examined, and most pathological changes in the kidneys are distinguishable with ultrasound. In this pictorial review, the most common findings in renal ultrasound...

  4. Spinal cord blood flow measured by 14C-iodoantipyrine autoradiography during and after graded spinal cord compression in rats

    International Nuclear Information System (INIS)

    Holtz, A.; Nystroem, B.G.; Gerdin, B.

    1989-01-01

    The relations between degree of thoracic spinal cord compression causing myelographic block, reversible paraparesis, and extinction of the sensory evoked potential on one hand, and spinal cord blood flow on the other, were investigated. This was done in rats using the blocking weight-technique and 14 C-iodoantipyrine autoradiography. A load of 9 g caused myelographic block. Five minutes of compression with that load caused a reduction of spinal cord blood flow to about 25%, but 5 and 60 minutes after the compression spinal cord blood flow was restored to 60% of the pretrauma value. A load of 35 g for 5 minutes caused transient paraparesis. Recovery to about 30% was observed 5 and 60 minutes thereafter. During compression at a load of 55 g, which caused almost total extinction of sensory evoked potential and irreversible paraplegia, spinal cord blood flow under the load ceased. The results indicate that myelographic block occurs at a load which does not cause irreversible paraparesis and that a load which permits sensory evoked potential to be elicited results in potentially salvageable damage

  5. Ultrasonography in Obstertrics

    International Nuclear Information System (INIS)

    Lee, Hyon U.

    1982-01-01

    The usefulness of pulse-echo ultrasonography of the practices of obstetrics has been great. It is more reliable than many biochemical and biophysical technics that have been developed in recent years to try to improve pregnancy outcome. When carefully performed and accurately interpreted, it can supply most vital information about the status of the fetus without any known risks to both mother and the fetus itself. The main obstertricalindications of ultrasonography coule be summarized as follows. 1. Diagnosis of early pregnancy. 2. Fetal growth and its maturity. 3. Complications of pregnancy and abnormal pregnancy. a) Vaginal bleeding in early intrauterinepregnancy. b) Multiple pregnancy. c) Ectopic pregnancy d) Hydatidiform mole e) Pelvic mass complicated with pregnancy f) Fetal anomaly 4. Fetal presenation and attitude 5. Placentography

  6. Ultrasonography of Neonatal Cholestasis

    Energy Technology Data Exchange (ETDEWEB)

    Cheon, Jung Eun [Seoul National University Hospital, Seoul (Korea, Republic of)

    2012-06-15

    Ultrasonography (US) is as an important tool for differentiation of obstructive and non-obstructive causes of jaundice in infants and children. Beyond two weeks of age, extrahepatic biliary atresia and neonatal hepatitis are the two most common causes of persistent neonatal jaundice: differentiation of extrahepatic biliary atresia, which requires early surgical intervention, is very important. Meticulous analysis should focus on size and configuration of the gallbladder and anatomical changes of the portahepatis. In order to narrow the differential diagnosis, combined approaches using hepatic scintigraphy, MR cholangiography, and, at times, percutaneous liver biopsy are necessary. US is useful for demonstrating choledochal cyst, bile plug syndrome, and spontaneous perforation of the extrahepatic bile duct

  7. Ultrasonography of ovarian hyperandrogenemia

    Science.gov (United States)

    Kuzmina, Svetlana A.; Zharkin, Nikolay A.

    2001-05-01

    The method of ultrasonography is high informative and widely used in diagnostics of ovarian hyperandrogenaemia. The majority of authors consider that a hyperplasia of a stroma is the main pathognomonic marker of polycystic ovaries (PCO). Still recently swell of a stroma was valued visually, that had subjective nature. We offer for the first time a way of diagnostics of stromal hyperplasia grounded on measurement of a volume of a stroma and ovary with ultrasound method, calculation of the ratio of a volume of the ovary to a volume of a stroma for every patient.

  8. Ultrasonography in the diagnosis of acute appendicitis. A study of 226 cases

    International Nuclear Information System (INIS)

    Alonso, J.M.; Sandoval, E.

    1998-01-01

    To determine the clinical value of ultrasound in the diagnosis of acute appendicitis. Graded-compression ultrasound was performed in 226 patients with atypical or unclear clinical signs of appendicitis. Twenty-three patients were excluded from study because of an inconclusive examination due to inadequate compression. Appendicitis was considered to be present when the appendix was non compressible and measured over 6 mn in anteroposterior diameter or the patient presented an abscess in right iliac fossa. The findings were confirmed by pathological study of surgically resected tissue or by clinical follow-up. The operative features and the predictive capacity of ultrasound in the diagnosis of acute appendicitis were calculated. In 98 cases, acute appendicitis was confirmed intraoperatively. In 103, this diagnosis was ruled out by the clinical course or intraoperative findings. Ninety-four patients presented ultrasonographic signs compatible with appendiceal inflammation. The sensitivity of ultrasound in the diagnosis of these doubtful cases of appendicitis was, 93.9%; the specificity, 98.1%; reliability, 96%; positive value, 9%; negative predictive value, 94.5%, and the positive probability rate, 49.3%. Our results indicate that high-resolution ultrasonography is indicated in all cases in which the clinical diagnosis of appendiceal inflammation id doubtful. (Author) 64 refs

  9. Ultrasonography in gastroenterology.

    Science.gov (United States)

    Ødegaard, Svein; Nesje, Lars B; Hausken, Trygve; Gilja, Odd Helge

    2015-06-01

    Ultrasonography (US) is a safe and available real-time, high-resolution imaging method, which during the last decades has been increasingly integrated as a clinical tool in gastroenterology. New US applications have emerged with enforced data software and new technical solutions, including strain evaluation, three-dimensional imaging and use of ultrasound contrast agents. Specific gastroenterologic applications have been developed by combining US with other diagnostic or therapeutic methods, such as endoscopy, manometry, puncture needles, diathermy and stents. US provides detailed structural information about visceral organs without hazard to the patients and can play an important clinical role by reducing the need for invasive procedures. This paper presents different aspects of US in gastroenterology, with a special emphasis on the contribution from Nordic scientists in developing clinical applications.

  10. Musculoskeletal ultrasonography in children

    International Nuclear Information System (INIS)

    Teo, E.-L.H.; Strouse, P.J.; Chhem, R.K.

    2002-01-01

    With the development of high-resolution ultrasound transducers, the role of ultrasonography (US) in evaluating the musculoskeletal system has increased. It is now possible to obtain detailed images of bones and soft-tissue structures that were previously unattainable. The advantages of US, when compared with other imaging modalities, are many. It is less expensive than magnetic resonance imaging (MRI) and computed tomography (CT). It does not expose the patient to ionizing radiation, so US examinations can be repeated without harm to the patient. Furthermore, US is performed in real-time, making it possible to assess the musculoskeletal system dynamically, in multiple planes and with contralateral comparison. In experienced hands, US is a quick, noninvasive and cost-effective way to assess the musculoskeletal system in children. It is used to evaluate soft-tissue masses, joint swelling, infections, lesions involving the chest and abdominal walls, bones, muscles and clubfoot deformity and to locate any foreign bodies. (author)

  11. Surgeon-performed ultrasonography.

    Science.gov (United States)

    Todsen, Tobias

    2017-11-01

    Surgeons are increasingly using ultrasonography (US) in their clinical management of patients. However, US is a very user-dependent imaging modality and proper skills of the US operator are needed to ensure quality in patient care. This thesis explores the validity evidence for assessment of competence in abdominal and head & neck ultrasonography using the Objective Structured Assessment of Ultrasound Skills (OSAUS) scale. With the use of Messick's unitary framework of validity, five sources of validity evidence were explored: test content, response processes, inter-nal structure, relations to other variables, and consequences. Research paper I examined validity evidence for the use of the OSAUS scale to assess physicians' abdominal point-of-care US competence in an experimental setting using patient cases with and without pathological conditions. The RESULTS provided validity evidence of the internal structure of the OSAUS scale and a deci-sion study predicted that four cases and two raters or five cases and one rater could ensure sufficient reliability in future test setups. The relation to other variables was supported by a signifi-cant difference in scores between US experience levels, and by a strong correlation between the OSAUS score and diagnostic accuracy. Research paper II explored the transfer of learning from formal point-of-care US training to performance on patients in a randomized controlled study. The RESULTS supported validity evi-dence regarding OSAUS scores' relation to other variables by demonstrating a significant discrimination in the progress of training-a more refined validity evidence than the relation to difference experience levels. The RESULTS showed that physicians could transfer the skills learned on an ultrasonography course to improved US performance and diagnostic accuracy on patients. However, the RESULTS also indicated that following an initial course, additional training is needed for physicians to achieve competence in US

  12. Evaluation of the activity of synovitis in patients with rheumatoid arthritis: Value of power Doppler ultrasonography

    International Nuclear Information System (INIS)

    Ahn, Joong Mo; Lim, Hyo Keun; Kim, Seung Hoon; Kim, Sung Hyun; Koh, Eun Mi; Kim, Jin Seok; Cha, Hoon Suk

    2001-01-01

    To correlate the grades on power Doppler ultrasonography with clinical disease activity indices and acute phase reactant values for assessing the activity of synovitis in patients with rheumatoid arthritis. Twenty patients with rheumatoid arthritis diagnosed on the basis of American College of power Doppler ultrasonography. Two experienced radiologists evaluated, in consensus, the power Doppler signals as follows: grade I=no flow or minimal flow, grade 2=mild flow, grade 3=moderate flow and grade 4= marked flow. The clinical disease activity indices consisted of the counts of tender joints and swollen joints, patient's assessment of pain, patient's global assessment of disease activity, physician's globe assessment of disease activity and patient's assessment of physical function. Acute-phase reactants included CRP and ESR. The grades on power Doppler ultrasonography were correlated with clinical disease activity indices as well as acute-phases reactant values by a use of Spearman rank correlation coefficient. The grades on power Doppler ultrasonography showed a statistically significant correlation with tender joint count (rs=.835; p<.05), swollen joint count (rs=.833; p<.05), physician's global assessment of disease activity (rs=.857; p<.05), CRP (rs=.838; P<.05) and ESR (rs=.838; p<.05). The power Doppler ultrasonography is an useful diagnostic modality for assessing the activity of synovitis in patients with rheumatoid arthritis.

  13. Transthoracic Ultrasonography for Clinicians

    Directory of Open Access Journals (Sweden)

    Morné Johan Vorster

    2015-04-01

    Full Text Available Transthoracic ultrasonography (US has become an essential tool for respiratory, emergency, and critical care physicians. It can be performed with basic equipment and by personnel with minimum training as a modality for the evaluation of a wide range of thoracic pathologies. Its advantages include immediate application at the point of care, low cost, and lack of radiation. The main indications for transthoracic US are the qualitative and quantitative assessment of pleural effusions, pleural thickening, diaphragmatic pathology, as well as chest wall and pleural tumors. Transthoracic US is also useful in visualizing pulmonary pathologies that abut the pleura, such as pneumonic consolidation and interstitial syndromes, including pulmonary edema. Transthoracic US is more sensitive than the traditional chest radiograph in the detection of pneumothoraces, and it is useful in diagnosing skeletal abnormalities such as rib fractures. It is the ideal tool to guide transthoracic procedures, including thoracocentesis and pleural biopsy. Moreover, transthoracic US-guided procedures can be performed by a single clinician with no sedation and minimal monitoring. Transthoracic US-guided fine needle aspiration and/or cutting needle biopsy of extrathoracic lymph nodes and lesions arising from the chest wall, pleura, peripheral lung, and mediastinum are safe to perform and have a high yield in the of hands of experienced clinicians. Transthoracic US can also potentially guide the aspiration and biopsy of diffuse pulmonary infiltrates, consolidations, and lung abscesses. Moreover, transthoracic US may be used in the detection of pulmonary embolism

  14. Advances in diagnostic ultrasonography.

    Science.gov (United States)

    Reef, V B

    1991-08-01

    A wide variety of ultrasonographic equipment currently is available for use in equine practice, but no one machine is optimal for every type of imaging. Image quality is the most important factor in equipment selection once the needs of the practitioner are ascertained. The transducer frequencies available, transducer footprints, depth of field displayed, frame rate, gray scale, simultaneous electrocardiography, Doppler, and functions to modify the image are all important considerations. The ability to make measurements off of videocassette recorder playback and future upgradability should be evaluated. Linear array and sector technology are the backbone of equine ultrasonography today. Linear array technology is most useful for a high-volume broodmare practice, whereas sector technology is ideal for a more general equine practice. The curved or convex linear scanner has more applications than the standard linear array and is equipped with the linear array rectal probe, which provides the equine practitioner with a more versatile unit for equine ultrasonographic evaluations. The annular array and phased array systems have improved image quality, but each has its own limitations. The new sector scanners still provide the most versatile affordable equipment for equine general practice.

  15. Introital ultrasonography in female urinary incontinence

    Energy Technology Data Exchange (ETDEWEB)

    Weon, Young Cheol; Cho, Kyoung Sik; Lee, Jin Seong; Choi, Sang Hee; Kim, Keon Seok; Choo, Myung Soo [Ulsan Univ. Asan Medical Center, Seoul (Korea, Republic of)

    1996-06-01

    To evaluate the usefulness of introital ultrasonography in the assessment of female urinary incontinence. Introital ultrasonography was performed in fifteen with stress urinary incontinence(mean age 50) and six patients without symptoms of incontinence(mean age 37). Using a sagittal section of the anterior pelvis in the plane of the symphysis pubis the posterior urethrovesical angle, the pubourethral distance and the pubo-yregrak abgle were measured at rest and during stress(Valsalva's maneuver state). The student T-test and the ANOVA test were used in statistical analysis. The posterior urethrovesical angles of the controls were 125.3 deg ({+-}10.9) at rest and 125.7 deg ({+-}7.6) during stress. In the patients, the corresponding angles were 135.3 deg ({+-}11.3) and 139.6 deg({+-}10.8). The posterior urethrovesical angles increased 0.3 deg ({+-}4.7) in the controls and 5.6 deg ({+-}4.0) in the patients(p=0.018). In the controls, the pubo-urethral distances were 21.8 mm({+-}5.8) at rest and 18.2 mm({+-}7.1) during stress, while in the patients these distances were 18.4 mm({+-}3.9) and 12.6 mm({+-}4.4). The pubo-urethral distance decreased 3.5 mm ({+-}1.5) in the controls and 5.8 mm ({+-}2.3) in the patients(p=0.039). In the patients with mild incontinence(Grade I), the posterior urethrovesical angles increased 3.4 deg ({+-}2.8) : 132.3 deg ({+-}12.5) at rest and 135.6 deg (12.8) during stress. In the patients with moderate incontinence(Grade II), the angles increased 8.1 deg({+-}3.8) : 136.0 deg({+-}6.5) at rest and 144.1 deg({+-}5.9) during stress. The change of the posterior urethrovesical angle was related to the grade of urinary incontinence in the patients(p<0.05). There was no statistical significancy in the pubo-urethral angle (p=0.315). Introital ultrasonography may be useful for assessment of stress urinary incontinence.

  16. Assessment of effectiveness of ultrasonography in diagnosis of acute appendicitis: Correlation with level of initial clinical diagnostic confidence

    International Nuclear Information System (INIS)

    Song, Soon Young; Koo, Ja Hong; Lee, Eun Ja; Lee, Jong In; Jung, Jin Ho; Kim, Jin Young; Oh, Hwa Eun; Moon, Won Jin; Kim, Sam Soo; Heon, Han

    2002-01-01

    To evaluate effectiveness of ultrasonography (US) in the diagnosis of acute appendicitis by comparing with initial level of clinical diagnostic confidence. Graded compression US of one hundred forty eight with clinically suspected of acute appendicitis were prospectively evaluated. General surgeons classified patients into three groups bases on the clinical probability before US examination: group 1 as cases with low probability ( 75%). Two radiologists performed US examination. Statistical significance of ultrasonographic results in each group was assessed. The sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV) and accuracy of sonography for all patients were 91.3%, 97%, 97.3%, 90.4%, and 93.9% respectively. Those of group 1 were 100%, 95.5%, 84.6%, 100%, and 96.4%, and those of group 2, 95.8%, 100%, 100%, 95%, and 97.7% while those of group 3, 86.4%, 100%, 100%, 50%, and 88%. There was no statistical difference in each parameter among three groups. The accuracy and NPV in group 3 was significantly higher than those in groups with the low and intermediate probability (group 1 and 2). Ultrasonography in the diagnosis of acute appendicitis is an useful and reliable method, especially in case of low clinical diagnostic confidence.

  17. Transvaginal ultrasonography of rectal endometriosis

    DEFF Research Database (Denmark)

    Egekvist, Anne Gisselmann; Seyer-Hansen, Mikkel; Forman, Axel

    Objectives: The aim of this present study was to evaluate the interobserver variation of transvaginal ultrasonographic measurements of endometriosis infiltrating the rectosigmoid wall. Methods: Transvaginal ultrasonography was performed independently by two observers. Observer 1 had several years...... of experience in ultrasonography while observer 2 was a medical student with no prior experience in ultrasonography or endometriosis. In 24 patient length, width and depth of endometriosis infiltrating the rectosigmoid bowel was measured. The differences between the observers were analysed by Bland and Altman...... for a relatively short period gives comparable scanning results between the two observers. It seems that transvaginal ultrasound could be used as a diagnostic tool for rectal endometriosis in most departments. However, the irregular morphology of the lesions makes the measurements very complex, and a strict...

  18. Ultrasonography in the evaluation of tongue and mouth pathology

    International Nuclear Information System (INIS)

    Lee, Chan Wha; Chung, Tae Sub; Suh, Jung Ho; Kim, Dong Ik; Lee, Jong Tae; Hong, Won Pyo; Park, Hyung Sik

    1991-01-01

    The evaluation of the tongue and mouth floor using the CT scan can be limited due to dental artifacts. Because the therapeutic plan depends on the nature and the cancer staging of lesions, it is essential to obtain accurate evaluation of lesions. In this study are explored the of Ultrasonography for the evaluation of tongue and mouth floor pathology. We have obtained ultrasonograms in 20 patients who had benign and malignant lesions in the tongue and mouth floor. Comparative analysis was made on 15 patients who underwent both CT and ultrasonography. We used the bimanual compression technique and the phonation technique during real-time scanning. Out of 15 cases, six had tongue cancer, and seven of them had cancer of the mouth floor. The other cases included a ranula, a dermoid cyst, a Ludwig's angina, and abscess of salivary gland, and one care with stones of the submandibular gland. All the benign and malignant masses appeared hypoechoic. Even though the lesions of tongue and mouth floor could not be evaluated by CT scan due to dental artifacts and extremely small size in 5 cases, ultrasonogram using the bimanual compression technique demonstrated good localization of the lesion, and also was greatly helpful in visualizing the invasion of the surrounding structures. Ultrasonography of the tongue and mouth floor proved to be superior to the CT scan not only in delineating the size and extent of the primary lesion, but also in visualizing invasion of surrounding structures

  19. Ultrasonography of the equine shoulder

    International Nuclear Information System (INIS)

    Dik, K.J.

    1996-01-01

    Six horses with shoulder injuries were presented in this report with emphasis on the use of ultrasonography vs. radiography in diagnosis. The two imaging modalities represented valuable and complementary diagnostic procedures. Two horses had fracture fragments of the lateral humeral tuberosity, the accurate ultrasonographic findings encouraging clearer radiographic identification by oblique projections. In one horseultrasonography enabled more accurate localization of calcification within the supraspinatus muscle. In the remaining three cases ultrasonography visualized distension of the bicipital bursa due to aseptic bursitis, bursal hemorrhage, or associated with injury of the biceps brachii muscle and the underlying intermediate humeral tubercle, the bony involvement more clearly demonstrated radiographically

  20. The role of ultrasonography in examination of the stability of Tile-B2 pelvic fractures: 7 case reports and a literature review.

    Science.gov (United States)

    Zhang, Bin-Fei; Zhang, Hong; Wang, Peng-Fei; Wang, Hu; Lei, Jin-Lai; Fu, Ya-Hui; Cong, Yu-Xuan; Huang, Hai; Huo, Xiao-Ming; Zhuang, Yan; Zhang, Kun

    2017-09-01

    Determining whether a Tile-B2 pelvic fracture is stable is very challenging. We sought to identify the role of ultrasonography in determining the stability of Tile-B2 pelvic fractures. We collected the clinical data of patients with Tile-B2 pelvic fractures who presented at Xi'an Hong-Hui Hospital between June 1, 2016, and August 5, 2016. The treatment strategy of each patient was determined by a team of senior surgeons in the department. A single sinologist observed the movement of the fracture sites in patients during rest, under compression, and during separation to determine fracture stability. According to the pelvic fracture stability assessment, an appropriate treatment strategy was redetermined. Overall, 7 patients, including 5 women and 2 men, with Tile-B2 pelvic fractures were included in this case series. During the initial examination, senior surgeons recommended that 2 patients should undergo internal fixation and 4 patients, conservative treatment; treatment was undecided for 1 patient. After ultrasonography examination, 4 patients underwent surgery via the Stoppa (n = 2) or ilioinguinal approach (n = 1) or cannulated screw fixation (n = 1). The rest of the patients (n = 3) received conventional treatment. Follow-up ranged from 6 to 10 months. Most of the patients showed excellent functions based on their last Majeed grading scores. There were no complications during the follow-up. Using ultrasonography examination, the preoperative treatment plan in 1 patient was changed, and the uncertain preoperative plan in 1 patient was identified. Preoperative assessment of stability using ultrasonography may assist surgeons in making appropriate treatment choices for patients with Tile-B2 pelvic fractures.

  1. Ultrasonography of the Rotator Cuff

    International Nuclear Information System (INIS)

    Yoon, Yong Cheol

    2006-01-01

    The ultrasonography (US) is an important modality in evaluating shoulder disease. It is accurate in diagnosing the various shoulder diseases including tendinosis, calcific tendinitis, and subacromial bursitis as well as rotator cuff tears. This article presents a pictorial review of US anatomy of the shoulder, the technical aspects of shoulder US, major types of shoulder pathology, and interventional procedure under US guidance

  2. Ultrasonography of the Rotator Cuff

    Energy Technology Data Exchange (ETDEWEB)

    Yoon, Yong Cheol [Samsung Medica Center, Sungkyunkwan University College of Medicine, Seoul (Korea, Republic of)

    2006-09-15

    The ultrasonography (US) is an important modality in evaluating shoulder disease. It is accurate in diagnosing the various shoulder diseases including tendinosis, calcific tendinitis, and subacromial bursitis as well as rotator cuff tears. This article presents a pictorial review of US anatomy of the shoulder, the technical aspects of shoulder US, major types of shoulder pathology, and interventional procedure under US guidance

  3. Urinary tract infection in children: Role of ultrasonography

    International Nuclear Information System (INIS)

    Lee, Hye Won; Lee, Sun Wha; Ko, Young Tae; Lim, Joo Won

    1994-01-01

    To evaluate diagnostic usefulness of ultrasonography(US) in pediatric patient with urinary tract infection. Fifty-five children with urinary tract infection underwent renal ultrasonography and voiding cystourethrography(VCUG). The imaging findings were analyzed retrospectively. Renal sonograms were normal in 34 of 55 children(62%). Five of 34 patients with normal sonogram had vesicoureteral reflux of grade I and III on VCUG. Renal sonograms were abnormal in 21 of 55 children(38%). Sonographic findings included hydronephrosis, hyperechoic kidney, nephromegaly, altrophic kidney, renal abscess, and duplex ureter. Eleven of 21 patient with abnormal sonogram had vesicoureteral reflux of grade I to IV on VCUG. Ultrasonography is an useful and reliable initial screening examination in the investigation of children with UTI. Unfortunately US is neither sufficiently sensitive nor specific for detecting VUR. VCUG provides confirmative and valuable information about vesicoureteral reflux, and VCUG should be considered as a next modality for UTI. The combined use of sonography and VCUG provides more valuable information in urinary tract infection

  4. Diagnostic nerve ultrasonography; Diagnostische Nervensonographie

    Energy Technology Data Exchange (ETDEWEB)

    Baeumer, T. [Universitaet zu Luebeck CBBM, Haus 66, Institut fuer Neurogenetik, Luebeck (Germany); Grimm, A. [Universitaetsklinikum Tuebingen, Klinik und Poliklinik fuer Neurologie, Tuebingen (Germany); Schelle, T. [Staedtisches Klinikum Dessau, Neurologische Klinik, Dessau (Germany)

    2017-03-15

    For the diagnostics of nerve lesions an imaging method is necessary to visualize peripheral nerves and their surrounding structures for an etiological classification. Clinical neurological and electrophysiological investigations provide functional information about nerve lesions. The information provided by a standard magnetic resonance imaging (MRI) examination is inadequate for peripheral nerve diagnostics; however, MRI neurography is suitable but on the other hand a resource and time-consuming method. Using ultrasonography for peripheral nerve diagnostics. With ultrasonography reliable diagnostics of entrapment neuropathies and traumatic nerve lesions are possible. The use of ultrasonography for neuropathies shows that a differentiation between different forms is possible. Nerve ultrasonography is an established diagnostic tool. In addition to the clinical examination and clinical electrophysiology, structural information can be obtained, which results in a clear improvement in the diagnostics. Ultrasonography has become an integral part of the diagnostic work-up of peripheral nerve lesions in neurophysiological departments. Nerve ultrasonography is recommended for the diagnostic work-up of peripheral nerve lesions in addition to clinical and electrophysiological investigations. It should be used in the clinical work-up of entrapment neuropathies, traumatic nerve lesions and spacy-occupying lesions of nerves. (orig.) [German] Fuer die Diagnostik von Nervenlaesionen ist ein bildgebendes Verfahren zur Darstellung des peripheren Nervs und seiner ihn umgebenden Strukturen fuer eine aetiologische Einordnung erforderlich. Mit der klinisch-neurologischen Untersuchung und Elektrophysiologie ist eine funktionelle Aussage ueber die Nervenlaesion moeglich. In der Standard-MRT-Untersuchung wird der periphere Nerv nur unzureichend gut dargestellt. Die MRT-Neurographie ist ein sehr gutes, aber auch zeit- und ressourcenintensives Verfahren. Nutzung des Ultraschalls fuer die

  5. Ultrasonography of the canine pancreas

    Directory of Open Access Journals (Sweden)

    Michelle L Avante

    2018-01-01

    Full Text Available This study describes the ultrasonographic techniques currently used in the evaluation of the canine pancreas. Ultrasonography was the first method to enable direct visualization of the pancreas in humans and it has been subsequently applied to animals. Currently, it is the method of choice for pancreatic evaluation and is essential as a diagnostic tool in the detection of abnormalities, especially tumors. Innovative equipment technology has led to the emergence of techniques complementary to B-mode ultrasound; such as Doppler, elastography, and contrast-enhanced ultrasonography, which have enabled more accurate diagnosis. Doppler provides information on vascular architecture and the hemodynamic aspect of blood vessels in multiple organs. ARFI elastography provides detailed images of the alterations detected by conventional examination (qualitative method and assists in differentiating between benign and malignant processes (quantitative method. Microbubble contrast agents determine parameters related to homogeneous and heterogeneous filling of organs with microbubbles, mainly nodular areas, thus defining high and low intensity patterns.

  6. Ultrasonography findings of gastric carcinoma

    International Nuclear Information System (INIS)

    Chung, Chong Ku; Choi, Ji Bai; Ko, Young Tae; Lim, Jae Hoon; Kim, Soon Young

    1985-01-01

    Stomach carcinoma is more common disease in Korea than western countries. The reported ultrasonographic findings of gastric carcinoma were thickening of gastric wall and 'pseudokidney' sign. The author analyzed ultrasonographic findings of 101 cases with gastric carcinoma who were performed ultrasonography and gastroscopy at Kyung Hee University Hospital from October 1982 to October 1985. The results were as followings; 1. Types of gastric carcinoma were consisted with infiltrative type 68 cases, infiltrative type with ulceration 16 cases, polypoid type with ulceration 1 case, infiltrative adn polypoid type 4 cases, limits plastica type 3 cases, ulcerative type 1 case and polypoid type 1 case. 2. Extent of the lesions were in body and antrum 45 cases, entire stomach 18 cases, antrum 18 cases, body 12 cases, body and fundus 6 cases. 3. Ultrasonography was useful in demonstrating the extent of the tumor and the presence of materials elsewhere in abdomen

  7. Ultrasonography findings of gastric carcinoma

    Energy Technology Data Exchange (ETDEWEB)

    Chung, Chong Ku; Choi, Ji Bai; Ko, Young Tae; Lim, Jae Hoon; Kim, Soon Young [Kyung Hee University Hospital, Seoul (Korea, Republic of)

    1985-12-15

    Stomach carcinoma is more common disease in Korea than western countries. The reported ultrasonographic findings of gastric carcinoma were thickening of gastric wall and 'pseudokidney' sign. The author analyzed ultrasonographic findings of 101 cases with gastric carcinoma who were performed ultrasonography and gastroscopy at Kyung Hee University Hospital from October 1982 to October 1985. The results were as followings; 1. Types of gastric carcinoma were consisted with infiltrative type 68 cases, infiltrative type with ulceration 16 cases, polypoid type with ulceration 1 case, infiltrative adn polypoid type 4 cases, limits plastica type 3 cases, ulcerative type 1 case and polypoid type 1 case. 2. Extent of the lesions were in body and antrum 45 cases, entire stomach 18 cases, antrum 18 cases, body 12 cases, body and fundus 6 cases. 3. Ultrasonography was useful in demonstrating the extent of the tumor and the presence of materials elsewhere in abdomen.

  8. Contrast-enhanced endoscopic ultrasonography

    DEFF Research Database (Denmark)

    Reddy, Nischita K; Ioncica, Ana Maria; Saftoiu, Adrian

    2011-01-01

    Contrast agents are increasingly being used to characterize the vasculature in an organ of interest, to better delineate benign from malignant pathology and to aid in staging and directing therapeutic procedures. We review the mechanisms of action of first, second and third generation contrast...... agents and their use in various endoscopic procedures in the gastrointestinal tract. Various applications of contrast-enhanced endoscopic ultrasonography include differentiating benign from malignant mediastinal lymphadenopathy, assessment of depth of invasion of esophageal, gastric and gall bladder...

  9. Abdominal ultrasonography, 2nd Ed

    International Nuclear Information System (INIS)

    Goldberg, B.B.

    1984-01-01

    This volume is a new and updated edition of an extensively illustrated text and reference on the capabilities and imaging of gray scale ultrasonography for each major abdominal organ. Each major organ system is treated separately, including liver, gallbladder and bile ducts, pancreas, kidney, retroperitoneum, abdominal vasculature, and more. There are over 500 illustrations and ten pages of full color plates for cross sectional anatomy

  10. Thyroid ultrasonography: Pitfalls and techniques

    Energy Technology Data Exchange (ETDEWEB)

    Choi, Seon hyeong; Kim, Eun Kyung; Kim, Soo Jin; Kwak, Jin Young [Dept. of Radiology, Research Institute of Radiological Science, Yonsei University College of Medicine, Seoul (Korea, Republic of)

    2014-04-15

    Thyroid ultrasonography (US) plays a key role in the diagnosis and management of thyroid-related diseases. The aim of this article was to illustrate various pitfalls that can occur in utilizing thyroid US and techniques to prevent them. In this article, we present cases demonstrating the common pitfalls associated with US equipment, performance, normal thyroid structures, misinterpretations, and surrounding structures. Knowledge of these areas is essential to avoid misdiagnosis or improper disease management.

  11. International guidelines for contrast-enhanced ultrasonography

    DEFF Research Database (Denmark)

    Nolsøe, Christian Pállson; Lorentzen, Torben

    2016-01-01

    The intent of this review is to discuss and comment on common clinical scenarios in which contrast-enhanced ultrasonography (CEUS) may play a decisive role and to illustrate important points with typical cases. With the advent of CEUS, the scope of indications for ultrasonography has been dramati...

  12. Contrast-enhanced endoscopic ultrasonography

    DEFF Research Database (Denmark)

    Reddy, Nischita K; Ioncică, Ana Maria; Săftoiu, Adrian

    2011-01-01

    Contrast agents are increasingly being used to characterize the vasculature in an organ of interest, to better delineate benign from malignant pathology and to aid in staging and directing therapeutic procedures. We review the mechanisms of action of first, second and third generation contrast...... agents and their use in various endoscopic procedures in the gastrointestinal tract. Various applications of contrast-enhanced endoscopic ultrasonography include differentiating benign from malignant mediastinal lymphadenopathy, assessment of depth of invasion of esophageal, gastric and gall bladder...... cancers and visualization of the portal venous system and esophageal varices. In addition, contrast agents can be used to differentiate pancreatic lesions. The use of color Doppler further increases the ability to diagnose and differentiate various pancreatic malignancies. The sensitivity of power Doppler...

  13. Evaluation of prenatal hydronephrosis: novel criteria for predicting vesicoureteral reflux on ultrasonography.

    Science.gov (United States)

    Lee, Nora G; Rushton, H Gil; Peters, Craig A; Groves, Danja S; Pohl, Hans G

    2014-09-01

    Radiographic evaluation for prenatal hydronephrosis often includes voiding cystourethrography to ascertain whether vesicoureteral reflux is present. We sought to determine whether use of voiding cystourethrography could be limited to those patients at greatest risk for vesicoureteral reflux. We hypothesized that vesicoureteral reflux could be predicted by findings on renal/bladder ultrasonography of hydroureter, renal dysmorphia and/or duplication. We reviewed the records of patients with prenatal hydronephrosis who underwent initial postnatal ultrasonography and voiding cystourethrography during a 3-year period. The presence of vesicoureteral reflux on voiding cystourethrogram was correlated to ultrasound findings, including hydronephrosis grade, presence of hydroureter, renal dysmorphia or duplication, with ultrasound considered positive for any of the latter 3 findings. Of 262 patients 47 (18%) had vesicoureteral reflux. Ultrasound was positive in 24 of 29 patients (83%) with high grade reflux and 12 of 18 (67%) with low grade reflux. If ultrasonography showed any of the 3 positive findings, the odds ratio of detecting vesicoureteral reflux was 8.07 (95% CI 3.86, 16.87). Using these criteria, among all cases of prenatal hydronephrosis 5 (2%) with high grade vesicoureteral reflux and 6 (2%) with low grade reflux would have been missed. Among the 47 cases of reflux overall 5 of 29 high grade (17%) and 6 of 18 low grade cases (33%) would have been missed. By using ultrasonography criteria of hydroureter, duplication and renal dysmorphia for patients with prenatal hydronephrosis, vesicoureteral reflux can be detected more specifically. Using our criteria, 165 of 262 voiding cystourethrograms (63%) could have been avoided in patients with prenatal hydronephrosis during a 3-year period. Reducing these evaluations may decrease risks regarding radiation exposure, family anxiety and health care costs. Copyright © 2014 American Urological Association Education and

  14. Collateral variations in circle of willis in atherosclerotic population assessed by means of transcranial color-coded duplex ultrasonography

    NARCIS (Netherlands)

    Hoksbergen, A. W.; Legemate, D. A.; Ubbink, D. T.; Jacobs, M. J.

    2000-01-01

    BACKGROUND AND PURPOSE: Transcranial color-coded duplex ultrasonography combined with common carotid artery (CCA) compression can be used to assess the collateral function of the circle of Willis. The aim of this study was to assess the unknown fraction of hemodynamic functional anterior and

  15. DNABIT Compress - Genome compression algorithm.

    Science.gov (United States)

    Rajarajeswari, Pothuraju; Apparao, Allam

    2011-01-22

    Data compression is concerned with how information is organized in data. Efficient storage means removal of redundancy from the data being stored in the DNA molecule. Data compression algorithms remove redundancy and are used to understand biologically important molecules. We present a compression algorithm, "DNABIT Compress" for DNA sequences based on a novel algorithm of assigning binary bits for smaller segments of DNA bases to compress both repetitive and non repetitive DNA sequence. Our proposed algorithm achieves the best compression ratio for DNA sequences for larger genome. Significantly better compression results show that "DNABIT Compress" algorithm is the best among the remaining compression algorithms. While achieving the best compression ratios for DNA sequences (Genomes),our new DNABIT Compress algorithm significantly improves the running time of all previous DNA compression programs. Assigning binary bits (Unique BIT CODE) for (Exact Repeats, Reverse Repeats) fragments of DNA sequence is also a unique concept introduced in this algorithm for the first time in DNA compression. This proposed new algorithm could achieve the best compression ratio as much as 1.58 bits/bases where the existing best methods could not achieve a ratio less than 1.72 bits/bases.

  16. II Brazilian consensus statement on endoscopic ultrasonography.

    Science.gov (United States)

    Maluf-Filho, Fauze; de Oliveira, Joel Fernandez; Mendonça, Ernesto Quaresma; Carbonari, Augusto; Maciente, Bruno Antônio; Salomão, Bruno Chaves; Medrado, Bruno Frederico; Dotti, Carlos Marcelo; Lopes, César Vivian; Braga, Cláudia Utsch; M Dutra, Daniel Alencar; Retes, Felipe; Nakao, Frank; de Sousa, Giovana Biasia; de Paulo, Gustavo Andrade; Ardengh, Jose Celso; Dos Santos, Juliana Bonfim; Sampaio, Luciana Moura; Okawa, Luciano; Rossini, Lucio; de Brito Cardoso, Manoel Carlos; Ribeiro Camunha, Marco Antonio; Clarêncio, Marcos; Lera Dos Santos, Marcos Eduardo; Franco, Matheus; Schneider, Nutianne Camargo; Mascarenhas, Ramiro; Roda, Rodrigo; Matuguma, Sérgio; Guaraldi, Simone; Figueiredo, Viviane

    2017-01-01

    At the time of its introduction in the early 80s, endoscopic ultrasonography (EUS) was indicated for diagnostic purposes. Recently, EUS has been employed to assist or to be the main platform of complex therapeutic interventions. From a series of relevant new topics in the literature and based on the need to complement the I Brazilian consensus on EUS, twenty experienced endosonographers identified and reviewed the pertinent literature in databases. The quality of evidence, strength of recommendations, and level of consensus were graded and voted on. Consensus was reached for eight relevant topics: treatment of gastric varices, staging of nonsmall cell lung cancer, biliary drainage, tissue sampling of subepithelial lesions (SELs), treatment of pancreatic fluid collections, tissue sampling of pancreatic solid lesions, celiac neurolysis, and evaluation of the incidental pancreatic cysts. There is a high level of evidence for staging of nonsmall cell lung cancer; biopsy of SELs as the safest method; unilateral and bilateral injection techniques are equivalent for EUS-guided celiac neurolysis, and in patients with visible ganglia, celiac ganglia neurolysis appears to lead to better results. There is a moderate level of evidence for: yield of tissue sampling of pancreatic solid lesions is not influenced by the needle shape, gauge, or employed aspiration technique; EUS-guided and percutaneous biliary drainage present similar clinical success and adverse event rates; plastic and metallic stents are equivalent in the EUS-guided treatment of pancreatic pseudocyst. There is a low level of evidence in the routine use of EUS-guided treatment of gastric varices.

  17. Compression stockings

    Science.gov (United States)

    Call your health insurance or prescription plan: Find out if they pay for compression stockings. Ask if your durable medical equipment benefit pays for compression stockings. Get a prescription from your doctor. Find a medical equipment store where they can ...

  18. The color Doppler ultrasonography in in the diagnosis of deep vein thrombosis

    International Nuclear Information System (INIS)

    Ameneiro Perez, Santiago; Alvarez Sanchez, Jose A.; Rodriguez Villalonga, Luis; Borras Migues, Marisela; Quinnones Castro, Mayda

    2004-01-01

    The paper was aimed at evaluating the accuracy of color Doppler ultrasonography, a noninvasive method, in the diagnosis of deep vein thrombosis of the lower limbs, comparing it to the results of the cruel and costly diagnostic g olden rule , that is, phlebography. Methods: Color Doppler ultrasonography served to assess 102 patients clinically suspected of deep vein thrombosis of the lower limbs, taking into account the following criteria: vein compressibility, echographic images, color, Vein Doppler signal modulation after several maneuvers and distal compression. Sensitivity, specificity, positive and negative predictive values and diagnostic efficacy were estimated for each criteria, taking the phlebography as a reference. Results: Total or partial lack of vein compressibility combined with the vein flow evaluation is the ultrasonographic criterion that reveals higher degree of sensitivity, specificity and efficacy (0,98; 0,95 and 0,97 respectively. Color Doppler ultrasonography is a highly effective noninvasive diagnostic method that detects deep vein thrombosis in proximal areas of the lower limbs

  19. [Ultrasonography in acute pelvic pain].

    Science.gov (United States)

    Kupesić, Sanja; Aksamija, Alenka; Vucić, Niksa; Tripalo, Ana; Kurjak, Asim

    2002-01-01

    Acute pelvic pain may be the manifestation of various gynecologic and non-gynecologic disorders from less alarming rupture of the follicular cyst to life threatening conditions such as rupture of ectopic pregnancy or perforation of inflamed appendix. In order to construct an algorithm for differential diagnosis we divide acute pelvic pain into gynecologic and non-gynecologic etiology, which is than subdivided into gastrointestinal and urinary causes. Appendicitis is the most common surgical emergency and should always be considered in differential diagnosis if appendix has not been removed. Apart of clinical examination and laboratory tests, an ultrasound examination is sensitive up to 90% and specific up to 95% if graded compression technique is used. Still it is user-depended and requires considerable experience in order to perform it reliably. Meckel's diverticulitis, acute terminal ileitis, mesenteric lymphadenitis and functional bowel disease are conditions that should be differentiated from other causes of low abdominal pain by clinical presentation, laboratory and imaging tests. Dilatation of renal pelvis and ureter are typical signs of obstructive uropathy and may be efficiently detected by ultrasound. Additional thinning of renal parenchyma suggests long-term obstructive uropathy. Ruptured ectopic pregnancy, salpingitis and hemorrhagic ovarian cysts are three most commonly diagnosed gynecologic conditions presenting as an acute abdomen. Degenerating leiomyomas and adnexal torsion occur less frequently. For better systematization, gynecologic causes of acute pelvic pain could be divided into conditions with negative pregnancy test and conditions with positive pregnancy test. Pelvic inflammatory disease may be ultrasonically presented with numerous signs such as thickening of the tubal wall, incomplete septa within the dilated tube, demonstration of hyperechoic mural nodules, free fluid in the "cul-de-sac" etc. Color Doppler ultrasound contributes to more

  20. Formulation and in-vitro evaluation of directly compressed controlled release matrices of Losartan Potassium using Ethocel Grade 100 as rate retarding agent.

    Science.gov (United States)

    Khan, Kamran Ahmad; Khan, Gul Majid; Zeeshan Danish, Muhammad; Akhlaq; Khan, Haroon; Rehman, Fazal; Mehsud, Saifullah

    2015-12-30

    Current study was aimed to develop 200mg controlled release matrix tablets of Losartan Potassium using Ethocel 100 Premium and Ethocel 100 FP Premium as rate controlling polymer. In-vitro studies were performed according to USP Method-I in phosphate buffer (PH 6.8) using pharma test dissolution apparatus. The temperature of the dissolution medium was kept constant at 37±0.5°C at 100rpm. Flow properties, physical quality control tests, effect of polymer size and drug-to-polymers ratios were studied using different kinetics models such as 1st-order, zero-order, Hixon Crowell model, Highuchi model and Power law. Difference factor f1 and similarity factor f2 were applied for dissolution profiles against Cardaktin® tablets used as a reference formulation. The matrices with polymer ethocel 100 FP Premiums have prolonged the drug release rate as compared to polymer ethocel 100 Premiums. The n values matrices with polymer ethocel grade 100 ranged from 0.603 to 0.857 indicating that the drug release occurred by anomalous non fickian diffusion kinetics while then value of reference Cardaktin® tablet was measured as 0.125 indicating that these tablets do not follow power law. The dissolution profiles of test formulations were different than that of reference Cardaktin®. This suggests the polymer Ethocel grade 100 can be proficiently incorporated in fabrication and development of once a day controlled release matrix tablets. Copyright © 2015. Published by Elsevier B.V.

  1. Diagnostic sensitivity and interobserver agreement of radiography and ultrasonography for detecting trochlear ridge osteochondrosis lesions in the equine stifle.

    Science.gov (United States)

    Beccati, Francesca; Chalmers, Heather J; Dante, Sara; Lotto, Eleonora; Pepe, Marco

    2013-01-01

    Osteochondrosis lesions commonly occur on the femoral trochlear ridges in horses and radiography and ultrasonography are routinely used to diagnose these lesions. However, poor correlation has been found between radiographic and arthroscopic findings of affected trochlear ridges. Interobserver agreement for ultrasonographic diagnoses and correlation between ultrasonographic and arthroscopic findings have not been previously described. Objectives of this study were to describe diagnostic sensitivity and interobserver agreement of radiography and ultrasonography for detecting and grading osteochondrosis lesions of the equine trochlear ridges, using arthroscopy as the reference standard. Twenty-two horses were sampled. Two observers independently recorded radiographic and ultrasonographic findings without knowledge of arthroscopic findings. Imaging findings were compared between observers and with arthroscopic findings. Agreement between observers was moderate to excellent (κ 0.48-0.86) for detecting lesions using radiography and good to excellent (κ 0.74-0.87) for grading lesions using radiography. Agreement between observers was good to excellent (κ 0.78-0.94) for detecting lesions using ultrasonography and very good to excellent (κ 0.86-0.93) for grading lesions using ultrasonography. Diagnostic sensitivity was 84-88% for radiography and 100% for ultrasonography. Diagnostic specificity was 89-100% for radiography and 60-82% for ultrasonography. Agreement between radiography and arthroscopy was good (κ 0.64-0.78). Agreement between ultrasonography and arthroscopy was very good to excellent (κ 0.81-0.87). Findings from this study support ultrasound as a preferred method for predicting presence and severity of osteochondrosis lesions involving the femoral trochlear ridges in horses. © 2012 Veterinary Radiology & Ultrasound.

  2. Real-time tracheal ultrasonography for confirmation of endotracheal tube placement during cardiopulmonary resuscitation.

    Science.gov (United States)

    Chou, Hao-Chang; Chong, Kah-Meng; Sim, Shyh-Shyong; Ma, Matthew Huei-Ming; Liu, Shih-Hung; Chen, Nai-Chuan; Wu, Meng-Che; Fu, Chia-Ming; Wang, Chih-Hung; Lee, Chien-Chang; Lien, Wan-Ching; Chen, Shyr-Chyr

    2013-12-01

    This study aimed to evaluate the accuracy of tracheal ultrasonography for assessing endotracheal tube position during cardiopulmonary resuscitation (CPR). We performed a prospective observational study of patients undergoing emergency intubation during CPR. Real-time tracheal ultrasonography was performed during the intubation with the transducer placed transversely just above the suprasternal notch, to assess for endotracheal tube positioning and exclude esophageal intubation. The position of trachea was identified by a hyperechoic air-mucosa (A-M) interface with posterior reverberation artifact (comet-tail artifact). The endotracheal tube position was defined as endotracheal if single A-M interface with comet-tail artifact was observed. Endotracheal tube position was defined as intraesophageal if a second A-M interface appeared, suggesting a false second airway (double tract sign). The gold standard of correct endotracheal intubation was the combination of clinical auscultation and quantitative waveform capnography. The main outcome was the accuracy of tracheal ultrasonography in assessing endotracheal tube position during CPR. Among the 89 patients enrolled, 7 (7.8%) had esophageal intubations. The sensitivity, specificity, positive predictive value, and negative predictive value of tracheal ultrasonography were 100% (95% confidence interval [CI]: 94.4-100%), 85.7% (95% CI: 42.0-99.2%), 98.8% (95% CI: 92.5-99.0%) and 100% (95% CI: 54.7-100%), respectively. Positive and negative likelihood ratios were 7.0 (95% CI: 1.1-43.0) and 0.0, respectively. Real-time tracheal ultrasonography is an accurate method for identifying endotracheal tube position during CPR without the need for interruption of chest compression. Tracheal ultrasonography in resuscitation management may serve as a powerful adjunct in trained hands. Copyright © 2013 Elsevier Ireland Ltd. All rights reserved.

  3. Effect of Compression Garments on Physiological Responses After Uphill Running.

    Science.gov (United States)

    Struhár, Ivan; Kumstát, Michal; Králová, Dagmar Moc

    2018-03-01

    Limited practical recommendations related to wearing compression garments for athletes can be drawn from the literature at the present time. We aimed to identify the effects of compression garments on physiological and perceptual measures of performance and recovery after uphill running with different pressure and distributions of applied compression. In a random, double blinded study, 10 trained male runners undertook three 8 km treadmill runs at a 6% elevation rate, with the intensity of 75% VO2max while wearing low, medium grade compression garments and high reverse grade compression. In all the trials, compression garments were worn during 4 hours post run. Creatine kinase, measurements of muscle soreness, ankle strength of plantar/dorsal flexors and mean performance time were then measured. The best mean performance time was observed in the medium grade compression garments with the time difference being: medium grade compression garments vs. high reverse grade compression garments. A positive trend in increasing peak torque of plantar flexion (60º·s-1, 120º·s-1) was found in the medium grade compression garments: a difference between 24 and 48 hours post run. The highest pain tolerance shift in the gastrocnemius muscle was the medium grade compression garments, 24 hour post run, with the shift being +11.37% for the lateral head and 6.63% for the medial head. In conclusion, a beneficial trend in the promotion of running performance and decreasing muscle soreness within 24 hour post exercise was apparent in medium grade compression garments.

  4. Contrast-Enhanced Harmonic Ultrasonography for the Assessment of Prostate Cancer Aggressiveness: a Preliminary Study

    International Nuclear Information System (INIS)

    Zhu, Yunkai; Chen, Yaqing; Jiang, Jun; Wang, Ren; Zhou, Yongchang; Zhang, Huizhen

    2010-01-01

    To determine whether contrast-enhanced harmonic ultrasonography can be used to predict the aggressiveness of prostate cancer. Contrast-enhanced harmonic ultrasonography was performed in 103 patients suspected of prostate cancer before biopsy. Time intensity curves were reconstructed for systematic biopsy sites and sonographic abnormalities. The characteristics of the curves were described using hemodynamic indices including arrival time (AT), time-to-peak (TTP), and peak intensity (PI). The differences of hemodynamic indices between high-grade and low-grade cancer were analyzed and the correlations between the hemodynamic indices and biopsy Gleason score were studied. Prostate cancer was detected in 41 of 103 patients and there were significant differences in the hemodynamic indices between the biopsy sites of the non-malignant patients and prostate cancer lesions (p < 0.05). The prostate biopsies revealed 154 prostate cancer lesions, including 31 low-grade lesions and 123 high-grade lesions. The hemodynamic indices AT and TTP of highgrade tumors were significantly shorter than those of low-grade tumors (p = 0.001, 0.002). In addition, high-grade peripheral zone (PZ) tumors had higher PI than low-grade PZ tumors (p = 0.009). The PZ prostate cancer Gleason score correlated with PI, AT and TTP, with Spearman correlation coefficients of 0.223, -0.335, and -0.351, respectively (p = 0.013, < 0.001 and < 0.001). Contrast-enhanced ultrasound measurements of hemodynamic indices correlate with the prostate cancer Gleason score

  5. Radiologic image compression -- A review

    International Nuclear Information System (INIS)

    Wong, S.; Huang, H.K.; Zaremba, L.; Gooden, D.

    1995-01-01

    The objective of radiologic image compression is to reduce the data volume of and to achieve a lot bit rate in the digital representation of radiologic images without perceived loss of image quality. However, the demand for transmission bandwidth and storage space in the digital radiology environment, especially picture archiving and communication systems (PACS) and teleradiology, and the proliferating use of various imaging modalities, such as magnetic resonance imaging, computed tomography, ultrasonography, nuclear medicine, computed radiography, and digital subtraction angiography, continue to outstrip the capabilities of existing technologies. The availability of lossy coding techniques for clinical diagnoses further implicates many complex legal and regulatory issues. This paper reviews the recent progress of lossless and lossy radiologic image compression and presents the legal challenges of using lossy compression of medical records. To do so, the authors first describe the fundamental concepts of radiologic imaging and digitization. Then, the authors examine current compression technology in the field of medical imaging and discuss important regulatory policies and legal questions facing the use of compression in this field. The authors conclude with a summary of future challenges and research directions. 170 refs

  6. Ultrasonography and surgery of canine biliary diseases.

    Science.gov (United States)

    Vörös, K; Németh, T; Vrabély, T; Manczur, F; Tóth, J; Magdus, M; Perge, E

    2001-01-01

    Findings of hepatic and gallbladder ultrasonography were analyzed in 12 dogs with gallbladder and/or extrahepatic biliary tract obstruction and compared with the results of exploratory laparotomy. Hepatic ultrasonography demonstrated normal liver in 2 dogs and hepatic abnormalities in 10 animals. The following ultrasonographic diagnoses were established compared to surgical findings: gallbladder obstruction caused by bile sludge (correct/incorrect: 1/2, surgical diagnosis: choleliths in one case), gallbladder obstruction caused by neoplasm (0/1, surgical diagnosis: mucocele), gallbladder and extrahepatic biliary tract obstruction due to choleliths (3/3), extrahepatic biliary tract obstruction caused by pancreatic mass (1/1) and small intestinal volvulus (1/1). Bile peritonitis caused by gallbladder rupture (4/4) was correctly diagnosed by ultrasound, aided with ultrasonographically-guided abdominocentesis and peritoneal fluid analysis. Rupture of the gallbladder should be suspected in the presence of a small, echogenic gallbladder or in the absence of the organ together with free abdominal fluid during ultrasonography. Laparotomy was correctly indicated by ultrasonography in all cases. However, the direct cause of obstruction could not be determined in 2 of the 12 dogs by ultrasonography alone.

  7. Role of Ultrasonography in Acute Abdomen

    International Nuclear Information System (INIS)

    An, Ji Hyun; Lee, Yeon Hee; Kim, Tae Hoon; Yu, Pil Mun; Choi, Young Hi; Kim, Sang Joon; Kim, Seung Cheul; Cho, Jeong Hee; Jung, Jae Un

    1996-01-01

    Authors analyzed the distribution of diseases and compared ultrasonographic conclusions with confirmed diagnoses of emergency abdominal ultrasonographies in acute abdominal conditions. We evaluated the role of emergency abdominal ultrasonography especially in the decision of emergency operation. In one hundred and forty five patients, emergent abdominal ultrasonography was performed within on admission. We compared the sonographic conclusion with postoperative pathology and analyzed the diagnoses of medically treated diseases. Twenty-eight patients under vent surgery and 117 patients were treated conservatively. Among the surgically treated patients, 19 patients (70.4%) were correctly diagnosed by preoperative ultrasonography.These included acute appendicitis (N = 8), acute cholecystitis (n = 7), ovarian cyst torsion (n = 2), and liver abscess (n = 1). Correct preoperative diagnosis was not made in 9 patients, including acute appendicitis (n = 4),peritonitis due to bowel perforation (n = 2), ectopic pregnancy (n = 1), colonic diverticulitis (n = 1 ) and pelvic inflammatory disease (n = 1 ). Clinical follow up was possible in 50 patients among the non-operative patient group, and the clinical diagnoses were chronic liver disease (n = 14), acute pyelonephritis (n = 10), and biliary stone (n = 10). Emergent ultrasonography plays an important role in acute abdominal conditions by supporting the differential diagnosis of medical and surgical disease

  8. Role of Ultrasonography in Acute Abdomen

    Energy Technology Data Exchange (ETDEWEB)

    An, Ji Hyun; Lee, Yeon Hee; Kim, Tae Hoon; Yu, Pil Mun; Choi, Young Hi; Kim, Sang Joon; Kim, Seung Cheul; Cho, Jeong Hee [Dankook University College of Medicine, Cheonan (Korea, Republic of); Jung, Jae Un [Yonsei University College of Medicine, Seoul (Korea, Republic of)

    1996-12-15

    Authors analyzed the distribution of diseases and compared ultrasonographic conclusions with confirmed diagnoses of emergency abdominal ultrasonographies in acute abdominal conditions. We evaluated the role of emergency abdominal ultrasonography especially in the decision of emergency operation. In one hundred and forty five patients, emergent abdominal ultrasonography was performed within on admission. We compared the sonographic conclusion with postoperative pathology and analyzed the diagnoses of medically treated diseases. Twenty-eight patients underwent surgery and 117 patients were treated conservatively. Among the surgically treated patients, 19 patients (70.4%) were correctly diagnosed by preoperative ultrasonography.These included acute appendicitis (N = 8), acute cholecystitis (n = 7), ovarian cyst torsion (n = 2), and liver abscess (n = 1). Correct preoperative diagnosis was not made in 9 patients, including acute appendicitis (n = 4), peritonitis due to bowel perforation (n = 2), ectopic pregnancy (n = 1), colonic diverticulitis (n = 1) and pelvic inflammatory disease (n = 1). Clinical follow up was possible in 50 patients among the non-operative patient group, and the clinical diagnoses were chronic liver disease (n = 14), acute pyelonephritis (n = 10), and biliary stone (n = 10). Emergent ultrasonography plays an important role in acute abdominal conditions by supporting the differential diagnosis of medical and surgical disease

  9. Ultrasonography of the scrotum in adults

    Energy Technology Data Exchange (ETDEWEB)

    Kuhn, Anna L.; Scotegagna, Eduardo; Nowitaki, Kristina M.; Kim, Young M. [Dept. of UMass Memorial Medical Center, University of Massachusetts Medical Center, Worcester (United States)

    2016-07-15

    Ultrasonography is the ideal noninvasive imaging modality for evaluation of scrotal abnormalities. It is capable of differentiating the most important etiologies of acute scrotal pain and swelling, including epididymitis and testicular torsion, and is the imaging modality of choice in acute scrotal trauma. In patients presenting with palpable abnormality or scrotal swelling, ultrasonography can detect, locate, and characterize both intratesticular and extratesticular masses and other abnormalities. A 12-17 MHz high frequency linear array transducer provides excellent anatomic detail of the testicles and surrounding structures. In addition, vascular perfusion can be easily assessed using color and spectral Doppler analysis. In most cases of scrotal disease, the combination of clinical history, physical examination, and information obtained with ultrasonography is sufficient for diagnostic decision-making. This review covers the normal scrotal anatomy as well as various testicular and scrotal lesions.

  10. Diabetic Nephropathy : Evaluation with Doppler Ultrasonography

    International Nuclear Information System (INIS)

    Sim, Jung Suk; Kim, Seung Hyup; Kang, Heung Sik; Park, Jae Hyung; Han, Man Chung

    1996-01-01

    To compare Doppler ultrasonography with laboratory tests in evaluation of diabetic nephropathy. Fifty-five patients (mean age = 60, M : F = 26 : 29) with diabetes mellitus underwent renal Doppler ultrasonography. Resistive indices were compared with degree of proteinuria, serum creatinine level, and creatinine clearance rate. Eighteen patients who showed no proteinuria or microscopic proteinuria had a mean resistive index (RI) of 0.72 (SD, 0.05), 16 patients with macroscopic proteinuria without nephrotic syndrome had a mean RI of 0.82 (SD, 0.13), and 21 patients with nephrotic syndrome had a mean RI of 0.90 (SD, 0.12). Renal RI correlated highly with serum creatinine level (r = 0.62) and creatinine clearance rate (r = -0.43). Renal Doppler ultrasonography provides a useful indication of renal function in diabetic nephropathy but cannot offer an advantage over conventional laboratory test

  11. Scintigraphy and ultrasonography of various thyroid diseases

    International Nuclear Information System (INIS)

    Ban, Yoshio; Nagakura, Hozumi; Kawauchi, Akihiro; Fukunari, Nobuhiro; Itoh, Kunihiko; Higashi, Tomomitsu.

    1987-01-01

    We reported the usefulness of scintigraphy and ultrasonography of various thyroid diseases. The scintigraphy were useful information in the determination of functioning adenoma, location of ectopic thyroid glands and appearance of lang and bone metastasis of thyroid carcinoma. As ultrasonography were able to be observation of internal structure of thyroid gland, that maight be used to determined associated nodular lesions in diffuse goiter and differentiation between benign and malignant tumor in nodular goiter. In observation of calcifications of goiter, soft X rays apparatus were usefull tool. US, as initial diagnostic test before scintiscanning, provided useful information and minimized radiation exposure. (author)

  12. Transabdominal Ultrasonography of the Small Bowel

    Directory of Open Access Journals (Sweden)

    Rudolf Kralik

    2013-01-01

    Full Text Available In the era of double balloon enteroscopy, capsule endoscopy, CT, and MRI enterography is transabdominal ultrasonography (TUS underestimated method for evaluation of small bowel pathology. As often initial imagine method in abdominal complaints, nowadays has TUS much better diagnostic potential than two decades ago. High-resolution ultrasound probes with harmonic imaging significantly improve resolution of bowel wall in real time, with possibility to asses bowel peristalsis. Color flow doppler enables evaluation of intramural bowel vascularisation, pulse wave doppler helps to quantificate flow in coeliac and superior mesenteric arteries. Small intestine contrast ultrasonography with oral contrast fluid, as well as contrast enhanced ultrasonography with intravenous microbubble contrast also improves small bowel imaging. We present a review of small intestine pathology that should be detected during ultrasound examinations, discuss technical requirements, advantages and limitations of TUS, typical ultrasound signs of Crohn's disease, ileus, celiac disease, intussusception, infectious enteritis, tumours, ischemic and haemorrhagic conditions of small bowel. In the hands of experienced investigator, despite some significant limitations(obesity, meteorism, is transabdominal ultrasonography reliable, noninvasive and inexpensive alternative method to computerised tomography (CT and magnetic resonance imaging (MRI in small bowel examination.

  13. Emergency surgeon-performed hepatobiliary ultrasonography.

    LENUS (Irish Health Repository)

    Kell, M R

    2012-02-03

    BACKGROUND: Acute hepatobiliary pathology is a common general surgical emergency referral. Diagnosis requires imaging of the biliary tree by ultrasonography. The accuracy and impact of surgeon-performed ultrasonography (SUS) on the diagnosis of emergent hepatobiliary pathology was examined. METHODS: A prospective study, over a 6-month period, enrolled all patients with symptoms or signs of acute hepatobiliary pathology. Patients provided informed consent and underwent both SUS and standard radiology-performed ultrasonography (RUS). SUS was performed using a 2-5-MHz broadband portable ultrasound probe by two surgeons trained in ultrasonography, and RUS using a 2-5-MHz fixed unit. SUS results were correlated with those of RUS and pathological diagnoses. RESULTS: Fifty-three consecutive patients underwent 106 ultrasonographic investigations. SUS agreed with RUS in 50 (94.3 per cent) of 53 patients. SUS accurately detected cholelithiasis in all but two cases and no patient was inaccurately diagnosed as having cholelithiasis at SUS (95.2 per cent sensitivity and 100 per cent specificity). As an overall complementary diagnostic tool SUS provided the correct diagnosis in 96.2 per cent of patients. Time to scan was significantly shorter following SUS (3.1 versus 12.0 h, P < 0.05). CONCLUSION: SUS provides a rapid and accurate diagnosis of emergency hepatobiliary pathology and may contribute to the emergency management of hepatobiliary disease.

  14. Quantitative muscle ultrasonography in amyotrophic lateral sclerosis.

    NARCIS (Netherlands)

    Arts, I.M.P.; Rooij, F.G. van; Overeem, S.; Pillen, S.; Janssen, H.M.; Schelhaas, H.J.; Zwarts, M.J.

    2008-01-01

    In this study, we examined whether quantitative muscle ultrasonography can detect structural muscle changes in early-stage amyotrophic lateral sclerosis (ALS). Bilateral transverse scans were made of five muscles or muscle groups (sternocleidomastoid, biceps brachii/brachialis, forearm flexor group,

  15. Compression Characteristics of Solid Wastes as Backfill Materials

    OpenAIRE

    Meng Li; Jixiong Zhang; Rui Gao

    2016-01-01

    A self-made large-diameter compression steel chamber and a SANS material testing machine were chosen to perform a series of compression tests in order to fully understand the compression characteristics of differently graded filling gangue samples. The relationship between the stress-deformation modulus and stress-compression degree was analyzed comparatively. The results showed that, during compression, the deformation modulus of gangue grew linearly with stress, the overall relationship bet...

  16. Ultrasonography in Early Diagnosis of Heterotopic Ossification

    Directory of Open Access Journals (Sweden)

    Shan-Hui Lin

    2014-12-01

    Full Text Available We report here the case of a 32-year-old man with a history of traumatic brain injury who presented with swelling of his right thigh. Soft tissue ultrasonography performed 3 days after the onset of symptoms showed a heterogeneous hyperechoic lesion with the formation of cysts and hypervascularity in the right iliopsoas abutting the surface of the femoral bone. This became a diffuse echogenic plaque with a posterior acoustic shadowing 12 days later. A diagnosis of heterotopic ossification was made on the basis of the presence of typical ultrasonographic findings and was confirmed by pathology. We emphasize that an early diagnosis of heterotopic ossification can be made with ultrasonography and can lead to early treatment.

  17. Vascular access: the impact of ultrasonography

    Science.gov (United States)

    de Almeida, Carlos Eduardo Saldanha

    2016-01-01

    ABSTRACT Vascular punctures are often necessary in critically ill patients. They are secure, but not free of complications. Ultrasonography enhances safety of the procedure by decreasing puncture attempts, complications and costs. This study reviews important publications and the puncture technique using ultrasound, bringing part of the experience of the intensive care unit of the Hospital Israelita Albert Einstein, São Paulo (SP), Brazil, and discussing issues that should be considered in future studies. PMID:28076607

  18. Differential diagnosis of calf pain by ultrasonography

    Directory of Open Access Journals (Sweden)

    Luciano Augusto Botter

    2008-03-01

    Full Text Available This paper aims to evaluate the recent and numerous applications of ultrasonography in the differential diagnosis of conditions that affect the popliteal fossa and lower limbs, resulting in calf pain. Popliteal cysts and their ruptures, aneurysms, hematomas, cellulitis, abscesses, soft tissue tumors and other fluid collections are easily identified by this technique. Moreover, post-trauma and inflammatory conditions affecting muscles and tendons, muscle necrosis, deep venous thrombosis and superficial thrombophlebitis are very well demonstrated by the ultrasonographic screening.

  19. Real time ultrasonography in obstructive jaundice

    International Nuclear Information System (INIS)

    Cho, Kyung Sik; Kim, Ho Kyun; Sung, Nak Kwan; Kim, Soon Yong

    1982-01-01

    Ultrasonography is a predominantly accurate, relatively simple unique diagnostic method of obstructive jaundice. The ultrasonographic findings of obstructive jaundice are dilated intra- and extrahepatic duct with intraluminal hyper reflective echo or mass in and/ or around the bile duct. The superiority of high resolution real time ultrasonography for the diagnosis of obstructive jaundice is bases on the easy detectability of extra- and intrahepatic bile ducts by its multiple sectional images in a short time, the flexibility of probe and small crystal size. Author evaluated real time sonographic findings 46 obstructive jaundice patients confirmed by surgery or radiographical examinations. The results were: 1. Diameter of extrahepatic duct in obstructive jaundice were varied from normal to 4.0 Cm, mostly 8 to 10 mm in diameter (26%). Degree of dilatation of biliary duct appeared more prominent in cancer patients than other causes of obstruction. 2. The site of obstruction was detected in 85% (39/46) and its common site was common bile duct in 63% (29/46). 3. The diagnostic accuracy of choledocholithiasis and cancer was 82% (22/27) and 44% (4/9), respectively. Diagnostic accuracy of the real time ultrasonography in obstructive jaundice was over all 75% (34/46)

  20. Wellhead compression

    Energy Technology Data Exchange (ETDEWEB)

    Harrington, Joe [Sertco Industries, Inc., Okemah, OK (United States); Vazquez, Daniel [Hoerbiger Service Latin America Inc., Deerfield Beach, FL (United States); Jacobs, Denis Richard [Hoerbiger do Brasil Industria de Equipamentos, Cajamar, SP (Brazil)

    2012-07-01

    Over time, all wells experience a natural decline in oil and gas production. In gas wells, the major problems are liquid loading and low downhole differential pressures which negatively impact total gas production. As a form of artificial lift, wellhead compressors help reduce the tubing pressure resulting in gas velocities above the critical velocity needed to surface water, oil and condensate regaining lost production and increasing recoverable reserves. Best results come from reservoirs with high porosity, high permeability, high initial flow rates, low decline rates and high total cumulative production. In oil wells, excessive annulus gas pressure tends to inhibit both oil and gas production. Wellhead compression packages can provide a cost effective solution to these problems by reducing the system pressure in the tubing or annulus, allowing for an immediate increase in production rates. Wells furthest from the gathering compressor typically benefit the most from wellhead compression due to system pressure drops. Downstream compressors also benefit from higher suction pressures reducing overall compression horsepower requirements. Special care must be taken in selecting the best equipment for these applications. The successful implementation of wellhead compression from an economical standpoint hinges on the testing, installation and operation of the equipment. Key challenges and suggested equipment features designed to combat those challenges and successful case histories throughout Latin America are discussed below.(author)

  1. Use of dynamic 3-dimensional transvaginal and transrectal ultrasonography to assess posterior pelvic floor dysfunction related to obstructed defecation.

    Science.gov (United States)

    Murad-Regadas, Sthela M; Regadas Filho, Francisco Sergio Pinheiro; Regadas, Francisco Sergio Pinheiro; Rodrigues, Lusmar Veras; de J R Pereira, Jacyara; da S Fernandes, Graziela Olivia; Dealcanfreitas, Iris Daiana; Mendonca Filho, Jose Jader

    2014-02-01

    New ultrasound techniques may complement current diagnostic tools, and combined techniques may help to overcome the limitations of individual techniques for the diagnosis of anorectal dysfunction. A high degree of agreement has been demonstrated between echodefecography (dynamic 3-dimensional anorectal ultrasonography) and conventional defecography. Our aim was to evaluate the ability of a combined approach consisting of dynamic 3-dimensional transvaginal and transrectal ultrasonography by using a 3-dimensional biplane endoprobe to assess posterior pelvic floor dysfunctions related to obstructed defecation syndrome in comparison with echodefecography. This was a prospective, observational cohort study conducted at a tertiary-care hospital. Consecutive female patients with symptoms of obstructed defecation were eligible. Each patient underwent assessment of posterior pelvic floor dysfunctions with a combination of dynamic 3-dimensional transvaginal and transrectal ultrasonography by using a biplane transducer and with echodefecography. Kappa (κ) was calculated as an index of agreement between the techniques. Diagnostic accuracy (sensitivity, specificity, and positive and negative predictive values) of the combined technique in detection of posterior dysfunctions was assessed with echodefecography as the standard for comparison. A total of 33 women were evaluated. Substantial agreement was observed regarding normal relaxation and anismus. In detecting the absence or presence of rectocele, the 2 methods agreed in all cases. Near-perfect agreement was found for rectocele grade I, grade II, and grade III. Perfect agreement was found for entero/sigmoidocele, with near-perfect agreement for rectal intussusception. Using echodefecography as the standard for comparison, we found high diagnostic accuracy of transvaginal and transrectal ultrasonography in the detection of posterior dysfunctions. This combined technique should be compared with other dynamic techniques and

  2. Comparison of power Doppler and color Doppler ultrasonography in the detection of intrasticular blood flow of normal infants

    International Nuclear Information System (INIS)

    Shin, Sung Ran; Lee, Ho Kyoung; Lee, Won Gyun; Youk, Dong Joon; Rho, Taek Soo; Lee, Min Jin; Lee, Sang Chun

    1999-01-01

    To compare color Doppler ultrasonography (US) and power Doppler US in the detection of intratesticular blood flow in normal infants and to asses the symmetry of blood flow. Testicular blood flow was assessed prospectively in 100 testes of 50 infants with both power and color Doppler US. We compared the power Doppler with color Doppler to detect intratesticular blood. When the flow was detected, intratesticular blood flow was graded as follows: grade 1: single intratesticular Doppler signal ; grade 2: multiple intratesticular Doppler signals. The symmetry of intratesticular flow was assessed by using the same method. Intratesticular flow was detected in 72 (72%) and 68 (68%) testes on power and color Doppler US, respectively. In 76 testes (76%), intratesticular flow was detected in either one or both techniques. On power Doppler US, grade 1 was seen in 40 tests and grade 2 in 32 testes. On color Doppler US, grade 1 was noted in 52 testes and grade 2 in 16 testes. Testicular blood flow was symmetric on both power and color Doppler US in each patient. There was no difference between power Doppler and color Doppler ultrasonography in detecting intratesticular blood flow in normal infants.

  3. The Place of Ultrasonography in the Evaluation of Rib Fractures

    OpenAIRE

    Fulya Bakılan; Gökhan Yüce; Ahmet Çağdaş Biçen; Tanju Keten

    2015-01-01

    Objective: The aim of this study was to investigate whether ultrasonography is superior to chest x-ray in detecting rib fractures in patients with minor blunt chest trauma and chest pain. Materials and Methods: Ultrasonography findings of 32 patients with minor blunt chest trauma showing no evidence of a rib fracture on anteroposterior chest x-rays, were documented. Presence of cortical discontinuities, acoustic shadows, reverberation artifacts, and hematoma by ultrasonography was...

  4. Colour Doppler and microbubble contrast agent ultrasonography do not improve cancer detection rate in transrectal systematic prostate biopsy sampling.

    Science.gov (United States)

    Taverna, Gianluigi; Morandi, Giovanni; Seveso, Mauro; Giusti, Guido; Benetti, Alessio; Colombo, Piergiuseppe; Minuti, Francesco; Grizzi, Fabio; Graziotti, Pierpaolo

    2011-12-01

    What's known on the subject? and What does the study add? Transrectal gray-scale ultrasonography guided prostate biopsy sampling is the method for diagnosing prostate cancer (PC) in patients with an increased prostate specific antigen level and/or abnormal digital rectal examination. Several imaging strategies have been proposed to optimize the diagnostic value of biopsy sampling, although at the first biopsy nearly 10-30% of PC still remains undiagnosed. This study compares the PC detection rate when employing Colour Doppler ultransongraphy with or without the injection of SonoVue™ microbubble contrast agent, versus the transrectal ultrasongraphy-guided systematic biopsy sampling. The limited accuracy, sensitivity, specificity and the additional cost of using the contrast agent do not justify its routine application in PC detection. • To compare prostate cancer (PC) detection rate employing colour Doppler ultrasonography with or without SonoVue™ contrast agent with transrectal ultrasonography-guided systematic biopsy sampling. • A total of 300 patients with negative digital rectal examination and transrectal grey-scale ultrasonography, with PSA values ranging between 2.5 and 9.9 ng/mL, were randomized into three groups: 100 patients (group A) underwent transrectal ultrasonography-guided systematic bioptic sampling; 100 patients (group B) underwent colour Doppler ultrasonography, and 100 patients (group C) underwent colour Doppler ultrasonography before and during the injection of SonoVue™. • Contrast-enhanced targeted biopsies were sampled into hypervascularized areas of peripheral, transitional, apical or anterior prostate zones. • All the patients included in Groups B and C underwent a further 13 systematic prostate biopsies. The cancer detection rate was calculated for each group. • In 88 (29.3%) patients a histological diagnosis of PC was made, whereas 22 (7.4%) patients were diagnosed with high-grade prostatic intraepithelial

  5. Computed tomography of hepatocellular carcinoma. Comparison with scintigraphy and ultrasonography

    Energy Technology Data Exchange (ETDEWEB)

    Kaneko, Kuniyuki; Nakata, Hajime; Honda, Hiroshi [University of Occupational and Environmental Health, Kitakyushu, Fukuoka (Japan)

    1983-09-01

    The detectability of hepatocellular carcinoma by computed tomography (CT) was evaluated on 76 cases. The detectability by plain CT was 93% with only slight improvement following a drip infusion of contrast medium. A comparison of scintigraphy, ultrasonography, and CT was also done on 63 cases. From the standpoint of the overall detectability of the tumor, CT was as good as ultrasonography or scintigraphy. Several cases were positive only on either CT or ultrasonography but no case was positive on scintigraphy alone. We believe that the combination of CT and ultrasonography is the most reliable as the screening method.

  6. Speech Compression

    Directory of Open Access Journals (Sweden)

    Jerry D. Gibson

    2016-06-01

    Full Text Available Speech compression is a key technology underlying digital cellular communications, VoIP, voicemail, and voice response systems. We trace the evolution of speech coding based on the linear prediction model, highlight the key milestones in speech coding, and outline the structures of the most important speech coding standards. Current challenges, future research directions, fundamental limits on performance, and the critical open problem of speech coding for emergency first responders are all discussed.

  7. Effect of Compression Garments on Physiological Responses After Uphill Running

    Directory of Open Access Journals (Sweden)

    Struhár Ivan

    2018-03-01

    Full Text Available Limited practical recommendations related to wearing compression garments for athletes can be drawn from the literature at the present time. We aimed to identify the effects of compression garments on physiological and perceptual measures of performance and recovery after uphill running with different pressure and distributions of applied compression. In a random, double blinded study, 10 trained male runners undertook three 8 km treadmill runs at a 6% elevation rate, with the intensity of 75% VO2max while wearing low, medium grade compression garments and high reverse grade compression. In all the trials, compression garments were worn during 4 hours post run. Creatine kinase, measurements of muscle soreness, ankle strength of plantar/dorsal flexors and mean performance time were then measured. The best mean performance time was observed in the medium grade compression garments with the time difference being: medium grade compression garments vs. high reverse grade compression garments. A positive trend in increasing peak torque of plantar flexion (60o·s-1, 120o·s-1 was found in the medium grade compression garments: a difference between 24 and 48 hours post run. The highest pain tolerance shift in the gastrocnemius muscle was the medium grade compression garments, 24 hour post run, with the shift being +11.37% for the lateral head and 6.63% for the medial head. In conclusion, a beneficial trend in the promotion of running performance and decreasing muscle soreness within 24 hour post exercise was apparent in medium grade compression garments.

  8. APPLICATION OF LAPAROSCOPIC ULTRASONOGRAPHY IN ADNEXAL OPERATIONS

    Institute of Scientific and Technical Information of China (English)

    2002-01-01

    Objective:To explore the clinical value on application of laparoscopic ultrasonography (Lap US) in the adnexal operation. Methods:Eleven patients including 7 cases of tubal pregnancy, 3 cases of teratoma of ovary and 1 case of endometrial cyst of ovary were examined by LapUS, then operated with laparoscopy.Results:The results showed that the modality presented is a big progress over the traditional operative management for adnexal diseas. Conclusions:It is a good approach for micro-surgery in the adnexal operation by laparoscopy.

  9. Optically neuronavigated ultrasonography in an intraoperative magnetic resonance imaging environment.

    Science.gov (United States)

    Katisko, Jani P A; Koivukangas, John P

    2007-04-01

    To develop a clinically useful method that shows the corresponding planes of intraoperative two-dimensional ultrasonography and intraoperative magnetic resonance imaging (MRI) scans determined with an optical neuronavigator from an intraoperative three-dimensional MRI scan data set, and to determine the qualitative and the quantitative spatial correspondence between the ultrasonography and MRI scans. An ultrasound probe was interlinked with an ergonomic and MRI scan-compatible ultrasonography probe tracker to the optical neuronavigator used in a low-field intraoperative MRI scan environment for brain surgery. Spatial correspondence measurements were performed using a custom-made ultrasonography/MRI scan phantom. In this work, instruments to combine intraoperatively collected ultrasonography and MRI scan data with an optical localization method in a magnetic environment were developed. The ultrasonography transducer tracker played an important role. Furthermore, a phantom for ultrasonography and MRI scanning was produced. This is the first report, to our knowledge, regarding the possibility of combining the two most important intraoperative imaging modalities used in neurosurgery, ultrasonography and MRI scanning, to guide brain tumor surgery. The method was feasible and, as shown in an illustrative surgical case, has direct clinical impact on image-guided brain surgery. The spatial deviation between the ultrasonography and the MRI scans was, on average, 1.90 +/- 1.30 mm at depths of 0 to 120 mm from the ultrasonography probe. The overall result of this work is a unique method to guide the neurosurgical operation with neuronavigated ultrasonography imaging in an intraoperative MRI scanning environment. The relevance of the method is emphasized in minimally invasive neurosurgery.

  10. Ultrasonography of Skin Changes in Legs with Chronic Venous Disease.

    Science.gov (United States)

    Caggiati, A

    2016-10-01

    In daily practice, ultrasonography (US) is used only to designate the location and pattern of venous lesions. Skin US is not performed between routine venous investigations. Skin morphology is evaluated by the same probes used for routine Duplex evaluation of superficial veins. US findings from evident skin lesions are comparatively evaluated with those from the surrounding apparently normal skin and from the contralateral leg. Inflammation and dermal edema can be found in the apparently normal skin of C2 legs. Swollen legs show thickening of the subcutaneous layer as a result of diffuse soaking or anechoic cavities, with or without dermal edema. Chronic hypodermitis is characterized by inflammatory edema in initial phases, and by liposclerosis in advanced cases. Recrudescence of inflammation provokes focal rarefactions of the subcutaneous layer, possibly related to ulcer opening. In legs with venous disorders, sonography refines clinical evaluation of the skin and may reveal changes not highlighted by inspection. Some of these changes could require further investigation because they have not yet been explained or described. Skin sonography should improve knowledge of the natural history of skin changes, as well as contribute to a better grading of venous diseases severity In particular, US evidence of cutaneous and subcutaneous changes in C2 legs should be considered to stratify the treatment in C2 legs, by identifying those in which varicose veins are not simply a cosmetic problem. Copyright © 2016 European Society for Vascular Surgery. Published by Elsevier Ltd. All rights reserved.

  11. Musculoskeletal ultrasonography delineates ankle symptoms in rheumatoid arthritis.

    Science.gov (United States)

    Toyota, Yukihiro; Tamura, Maasa; Kirino, Yohei; Sugiyama, Yumiko; Tsuchida, Naomi; Kunishita, Yosuke; Kishimoto, Daiga; Kamiyama, Reikou; Miura, Yasushi; Minegishi, Kaoru; Yoshimi, Ryusuke; Ueda, Atsuhisa; Nakajima, Hideaki

    2017-05-01

    To clarify the use of musculoskeletal ultrasonography (US) of ankle joints in rheumatoid arthritis (RA). Consecutive RA patients with or without ankle symptoms participated in the study. The US, clinical examination (CE), and patients' visual analog scale for pain (pVAS) for ankles were assessed. Prevalence of tibiotalar joint synovitis and tenosynovitis were assessed by grayscale (GS) and power Doppler (PD) US using a semi-quantitative grading (0-3). The positive US and CE findings were defined as GS score ≥2 and/or PD score ≥1, and joint swelling and/or tenderness, respectively. Multivariate analysis with the generalized linear mixed model was performed by assigning ankle pVAS as a dependent variable. Among a total of 120 ankles from 60 RA patients, positive ankle US findings were found in 21 (35.0%) patients. The concordance rate of CE and US was moderate (kappa 0.57). Of the 88 CE negative ankles, US detected positive findings in 9 (10.2%) joints. Multivariate analysis revealed that ankle US, clinical disease activity index, and foot Health Assessment Questionnaire, but not CE, was independently associated with ankle pVAS. US examination is useful to illustrate RA ankle involvement, especially for patients who complain ankle pain but lack CE findings.

  12. Comparison between doppler ultrasonography and renal scintigraphy in assessment of post-transplant renal function

    Energy Technology Data Exchange (ETDEWEB)

    Yoon, Yeo Chang; Shin, Byung Seok; Ohm, Joon Young; Kim, Seong Min; Ahn, Moon Sang; Yang, Shin Seok [Chungnam National University Hospital, Daejeon (Korea, Republic of); Park, Mi Hyun [Dept. of Radiology, Dankook University Hospital, Cheonan (Korea, Republic of)

    2016-05-15

    To compare the usefulness of Doppler ultrasonography and renal scintigraphy in the assessment of short- and long-term function of transplanted kidneys. We retrospectively reviewed the cases of 79 patients who underwent Doppler ultrasonography and technetium-99m diethylene triamine pentaacetic acid renal scintigraphy on the same day, within 4 days of renal transplantation. Image parameters were evaluated for statistical differences. There was a strong positive correlation between the glomerular filtration rate (GFR) as measured by renal scintigraphy and the estimated GFR (eGFR) based on serum creatinine levels (correlation coefficient = 0.71). Scan grade according to the time-activity curve, resistive index, and end diastolic velocity showed moderate correlations with the eGFR (correlation coefficients = -0.557, -0.329, and 0.370, respectively) in the early post-transplantation period. The mean survival time was longer in patients with lower resistive indices (≤ 0.68, 54.9 months vs. > 0.68, 29.5 months) and lower pulsatility indices (≤ 1.32, 53.8 months vs. > 1.32, 28.7 months); however, there were no statistically significant differences in the long-term follow-up period (p = 0.121 for resistive index and p = 0.074 for pulsatility index). Renal scintigraphy is a more sensitive method than Doppler ultrasonography for assessing transplanted kidney function in the early post-transplantation period. Doppler ultrasonography might reflect the long-term survival time. However, it is difficult to predict long-term renal function using either method.

  13. Comparison between doppler ultrasonography and renal scintigraphy in assessment of post-transplant renal function

    International Nuclear Information System (INIS)

    Yoon, Yeo Chang; Shin, Byung Seok; Ohm, Joon Young; Kim, Seong Min; Ahn, Moon Sang; Yang, Shin Seok; Park, Mi Hyun

    2016-01-01

    To compare the usefulness of Doppler ultrasonography and renal scintigraphy in the assessment of short- and long-term function of transplanted kidneys. We retrospectively reviewed the cases of 79 patients who underwent Doppler ultrasonography and technetium-99m diethylene triamine pentaacetic acid renal scintigraphy on the same day, within 4 days of renal transplantation. Image parameters were evaluated for statistical differences. There was a strong positive correlation between the glomerular filtration rate (GFR) as measured by renal scintigraphy and the estimated GFR (eGFR) based on serum creatinine levels (correlation coefficient = 0.71). Scan grade according to the time-activity curve, resistive index, and end diastolic velocity showed moderate correlations with the eGFR (correlation coefficients = -0.557, -0.329, and 0.370, respectively) in the early post-transplantation period. The mean survival time was longer in patients with lower resistive indices (≤ 0.68, 54.9 months vs. > 0.68, 29.5 months) and lower pulsatility indices (≤ 1.32, 53.8 months vs. > 1.32, 28.7 months); however, there were no statistically significant differences in the long-term follow-up period (p = 0.121 for resistive index and p = 0.074 for pulsatility index). Renal scintigraphy is a more sensitive method than Doppler ultrasonography for assessing transplanted kidney function in the early post-transplantation period. Doppler ultrasonography might reflect the long-term survival time. However, it is difficult to predict long-term renal function using either method

  14. Diagnostic value of ultrasonography in evaluation and management ...

    African Journals Online (AJOL)

    Results: Common causes of acute abdominal emergencies in pediatric patients as noted on ultrasonography included nonspecifi c pain (28%), abdominal abscess (21%), acute appendicitis (7%) and intussusception (7%). Ultrasonography was diagnostic in 45.2% cases and supportive in 12.3% of the cases. As for as the fi ...

  15. Nuclear medicine and ultrasonography in the acute cholecystitis diagnosis

    International Nuclear Information System (INIS)

    Schmillevitch, J.; Serson, D.; Camera, A.J.; Oliveira Nunes, J.E. de; Bazzo, J.M.B.

    1980-01-01

    Newer modalities for the evaluation of gallbladder include cholescintigraphy and ultrasonography. The IDA-Tc 99m presents functional informations with regard to cystic duct patency. The ultrasonography demonstrates the topographic anatomy of gallbladder, and morfologic alterations. Both analysis are preconized in acute cholecystitis. (Author) [pt

  16. The Place of Ultrasonography in the Evaluation of Rib Fractures

    Directory of Open Access Journals (Sweden)

    Fulya Bakılan

    2015-12-01

    Full Text Available Objective: The aim of this study was to investigate whether ultrasonography is superior to chest x-ray in detecting rib fractures in patients with minor blunt chest trauma and chest pain. Materials and Methods: Ultrasonography findings of 32 patients with minor blunt chest trauma showing no evidence of a rib fracture on anteroposterior chest x-rays, were documented. Presence of cortical discontinuities, acoustic shadows, reverberation artifacts, and hematoma by ultrasonography was proposed as the diagnostic criteria for detecting the rib fracture. Results: Rib fracture was detected in 20 patients (62.5% according to ultrasonography results. A mildly displaced fracture was detected in 7 patients (35%, hematoma was detected in 3 patients (15% and multiple fractures (in 5th, 6th, 7th, and 8th ribs were detected in 1 patient (5%. Conclusion: The results of our study showed that ultrasonography is superior to chest x-ray, in detecting rib fractures.

  17. Ultrasonography as a non-invasive tool for detection of nonalcoholic fatty liver disease in overweight/obese Egyptian children

    International Nuclear Information System (INIS)

    El-Koofy, Nehal; El-Karaksy, Hanaa; El-Akel, Wafaa; Helmy, Heba; Anwar, Ghada; El-Sayed, Rokaya; El-Hennawy, Ahmad

    2012-01-01

    Introduction: Liver biopsy, although a gold standard in diagnosis of nonalcoholic fatty liver disease (NAFLD), is an invasive and expensive tool. Aim: To assess the diagnostic accuracy of abdominal ultrasound in detecting NAFLD among a group of overweight/obese children having one or more liver abnormality (clinical hepatomegaly, raised ALT or echogenic liver parenchyma by ultrasound). Methods: Seventy-eight overweight/obese children were referred to the Pediatric Hepatology Unit, Cairo University Pediatric Hospital, Egypt, for assessment for hepatic abnormalities. Out of the 78 children, 34 had one or more abnormality in the form of clinical hepatomegaly, raised alanine aminotransferase (ALT) and/or echogenic liver parenchyma by ultrasound. All 34 cases underwent liver biopsy for evaluation for NAFLD. Results: Histological NAFLD was detected in 15 cases; 8 simple steatosis and 7 nonalcoholic steatohepatitis (NASH). Sonographic evaluation of hepatic parenchymal echogenicity revealed: 11 with grade 1 echogenicity, 12 with grade 2 and 9 with grade 3 while only 2 had normal liver echopattern. Ultrasonography was 100% sensitive and 100% specific in detecting histological NAFLD, while the positive predictive value (PPV) was 47% and negative predictive value (NPV) was 11%. After consolidating the included children into 2 groups: the first including normal and grade 1 echogenicity and the second including grades 2 and 3, the sensitivity of ultrasonography in detecting histological NAFLD was still 100%, while negative predictive value increased to 100% with an accuracy of 82%. Conclusion: We conclude that ultrasonography is an important non invasive tool in assessment for NAFLD. Normal or grade 1 hepatic echogenicity can soundly exclude histological NAFLD and obviates the need for liver biopsy.

  18. Ultrasonography as a non-invasive tool for detection of nonalcoholic fatty liver disease in overweight/obese Egyptian children

    Energy Technology Data Exchange (ETDEWEB)

    El-Koofy, Nehal [Department of Pediatrics, Cairo University (Egypt); El-Karaksy, Hanaa, E-mail: hanaakaraksy@yahoo.com [Department of Pediatrics, Cairo University (Egypt); El-Akel, Wafaa [Tropical Medicine, Cairo University (Egypt); Helmy, Heba; Anwar, Ghada; El-Sayed, Rokaya [Department of Pediatrics, Cairo University (Egypt); El-Hennawy, Ahmad [Pathology, Faculty of Medicine, Cairo University (Egypt)

    2012-11-15

    Introduction: Liver biopsy, although a gold standard in diagnosis of nonalcoholic fatty liver disease (NAFLD), is an invasive and expensive tool. Aim: To assess the diagnostic accuracy of abdominal ultrasound in detecting NAFLD among a group of overweight/obese children having one or more liver abnormality (clinical hepatomegaly, raised ALT or echogenic liver parenchyma by ultrasound). Methods: Seventy-eight overweight/obese children were referred to the Pediatric Hepatology Unit, Cairo University Pediatric Hospital, Egypt, for assessment for hepatic abnormalities. Out of the 78 children, 34 had one or more abnormality in the form of clinical hepatomegaly, raised alanine aminotransferase (ALT) and/or echogenic liver parenchyma by ultrasound. All 34 cases underwent liver biopsy for evaluation for NAFLD. Results: Histological NAFLD was detected in 15 cases; 8 simple steatosis and 7 nonalcoholic steatohepatitis (NASH). Sonographic evaluation of hepatic parenchymal echogenicity revealed: 11 with grade 1 echogenicity, 12 with grade 2 and 9 with grade 3 while only 2 had normal liver echopattern. Ultrasonography was 100% sensitive and 100% specific in detecting histological NAFLD, while the positive predictive value (PPV) was 47% and negative predictive value (NPV) was 11%. After consolidating the included children into 2 groups: the first including normal and grade 1 echogenicity and the second including grades 2 and 3, the sensitivity of ultrasonography in detecting histological NAFLD was still 100%, while negative predictive value increased to 100% with an accuracy of 82%. Conclusion: We conclude that ultrasonography is an important non invasive tool in assessment for NAFLD. Normal or grade 1 hepatic echogenicity can soundly exclude histological NAFLD and obviates the need for liver biopsy.

  19. Ultrasonography of the pediatric hip and spine

    Energy Technology Data Exchange (ETDEWEB)

    Kang, Yeo Ryang; Koo, Joon Bun [Dept. of Radiology, Dongguk University Ilsan Hospital, Dongguk University College of Medicine, Goyang (Korea, Republic of)

    2017-07-15

    Ultrasonography (US) is a useful screening method for the diagnosis of developmental dysplasia of the hip (DDH) and congenital spinal anomalies in infants. In addition, US is a useful, noninvasive imaging modality for the diagnosis of transient synovitis in children. The early detection of DDH leads to a better prognosis without surgical intervention. Moreover, spinal US allows the detection of congenital malformations and can also demonstrate normal anatomy and normal variants that may resemble disorders. Therefore, radiologists should be familiar with the sonographic anatomy of the normal infant hip, scanning and measurement techniques for DDH, the US features of transient synovitis in children, spinal US techniques, and the US features of normal anatomical structures, normal variants, and congenital spinal anomalies.

  20. Current status of ultrasonography of the finger

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Seun Ah; Kim, Baek Hyun [Dept. of Radiology, Korea University Ansan Hospital, Korea University College of Medicine, Ansan (Korea, Republic of); Kim, Seon Jeong [Dept. of Radiology, Myongji Hospital, Seonam University College of Medicine, Goyang (Korea, Republic of); Kim, Ji Na [Dept. of Radiology, Chungnam National University Hospital, Chungnam National University School of Medicine, Daejeon (Korea, Republic of); Park, Sun Young [Dept. of Radiology, Hallym University Sacred Heart Hospital, Hallym University College of Medicine, Anyang (Korea, Republic of); Choi, Kyung Hee [Incheon Baek Hospital, Incheon (Korea, Republic of)

    2016-03-15

    The recent development of advanced high-resolution transducers has enabled the fast, easy, and dynamic ultrasonographic evaluation of small, superficial structures such as the finger. In order to best exploit these advances, it is important to understand the normal anatomy and the basic pathologies of the finger, as exemplified by the following conditions involving the dorsal, volar, and lateral sections of the finger: sagittal band injuries, mallet finger, and Boutonnière deformity (dorsal aspect); flexor tendon tears, trigger finger, and volar plate injuries (volar aspect); gamekeeper’s thumb (Stener lesions) and other collateral ligament tears (lateral aspect); and other lesions. This review provides a basis for understanding the ultrasonography of the finger and will therefore be useful for radiologists.

  1. Shoulder Ultrasonography: Performance and Common Findings

    Directory of Open Access Journals (Sweden)

    Diana Gaitini

    2012-01-01

    Full Text Available Ultrasound (US of the shoulder is the most commonly requested examination in musculoskeletal US diagnosis. Sports injuries and degenerative and inflammatory processes are the main sources of shoulder pain and functional limitations. Because of its availability, low cost, dynamic examination process, absence of radiation exposure, and ease of patient compliance, US is the preferred mode for shoulder imaging over other, more sophisticated, and expensive methods. Operator dependence is the main disadvantage of US examinations. Use of high range equipment with high resolution transducers, adhering to a strict examination protocol, good knowledge of normal anatomy and pathological processes and an awareness of common pitfalls are essential for the optimal performance and interpretation of shoulder US. This article addresses examination techniques, the normal sonographic appearance of tendons, bursae and joints, and the main pathological conditions found in shoulder ultrasonography.

  2. Current status of automated breast ultrasonography

    Directory of Open Access Journals (Sweden)

    Hee Jung Shin

    2015-07-01

    Full Text Available Breast ultrasonography (US is currently considered the first-line examination in the detection Epub ahead of print and characterization of breast lesions. However, conventional handheld US (HHUS has several limitations such as operator dependence and the requirement of a considerable amount of radiologist time for whole-breast US. Automated breast US (ABUS, recently approved by the United States Food and Drug Administration for screening purposes, has several advantages over HHUS, such as higher reproducibility, less operator dependence, and less required physician time for image acquisition. In addition, ABUS provides both a coronal view and a relatively large field of view. Recent studies have reported that ABUS is promising in US screening for women with dense breasts and can potentially replace handheld second-look US in a preoperative setting.

  3. Current status of ultrasonography of the finger

    Directory of Open Access Journals (Sweden)

    Seun Ah Lee

    2016-04-01

    Full Text Available The recent development of advanced high-resolution transducers has enabled the fast, easy, and dynamic ultrasonographic evaluation of small, superficial structures such as the finger. In order to best exploit these advances, it is important to understand the normal anatomy and the basic pathologies of the finger, as exemplified by the following conditions involving the dorsal, volar, and lateral sections of the finger: sagittal band injuries, mallet finger, and Boutonnière deformity (dorsal aspect; flexor tendon tears, trigger finger, and volar plate injuries (volar aspect; gamekeeper’s thumb (Stener lesions and other collateral ligament tears (lateral aspect; and other lesions. This review provides a basis for understanding the ultrasonography of the finger and will therefore be useful for radiologists.

  4. Ultrasonography of the pediatric hip and spine

    International Nuclear Information System (INIS)

    Kang, Yeo Ryang; Koo, Joon Bun

    2017-01-01

    Ultrasonography (US) is a useful screening method for the diagnosis of developmental dysplasia of the hip (DDH) and congenital spinal anomalies in infants. In addition, US is a useful, noninvasive imaging modality for the diagnosis of transient synovitis in children. The early detection of DDH leads to a better prognosis without surgical intervention. Moreover, spinal US allows the detection of congenital malformations and can also demonstrate normal anatomy and normal variants that may resemble disorders. Therefore, radiologists should be familiar with the sonographic anatomy of the normal infant hip, scanning and measurement techniques for DDH, the US features of transient synovitis in children, spinal US techniques, and the US features of normal anatomical structures, normal variants, and congenital spinal anomalies

  5. Prenatal diagnosis of hypophosphatasia congenita using ultrasonography

    Energy Technology Data Exchange (ETDEWEB)

    Guguloth, Ashwitha [Dept. of Radiology, Bangalore Medical College and Research Institute, Bangalore (India); Aswani, Yashant; Anandpara, Karan Manoj [Dept. of Radiology, Seth G S Medical College and KEM Hospital, Mumbai (India)

    2016-01-15

    Congenital hypophosphatasia is a rare fatal skeletal dysplasia. Antenatal determinants of Epub ahead of print lethality include small thoracic circumference with pulmonary hypoplasia and severe micromelia. These features were present in the fetus of a 25-year-old female who came for an anomaly scan in her second trimester of pregnancy. Additional findings of generalized demineralization and osteochondral spurs led to the diagnosis of hypophosphatasia congenita. The pregnancy was terminated, and the findings were confirmed on autopsy. Common differential diagnoses with clues to diagnose the above mentioned condition have been discussed here. Early and accurate detection of this medical condition is important as no treatment has been established for this condition. Therefore, antenatal ultrasonography helps in diagnosing and decision making with respect to the current pregnancy and lays the foundation for the genetic counseling of the couple.

  6. Abdominal Subcutaneous Fat Thickness Measured by Ultrasonography Correlates with Hyperlipidemia and Steatohepatitis in Obese Children.

    Science.gov (United States)

    Lee, Sung Hyun; Kim, Dongwan; Baek, Min Young; Tchah, Hann; Kim, Yeon Sun; Ryoo, Eell; Kim, Yun Mi

    2015-06-01

    The aim of this study is to evaluate the relationship between abdominal subcutaneous fat thickness measured by ultrasonography (US) and serum lipid profile and liver transaminases in obese children. One hundred and sixty-six children diagnosed with obesity from May 2001 to December 2013 were included in this study. Data on serum lipid profile and liver transaminases were collected from clinical records. Abdominal subcutaneous fat thickness and grade of hepatic steatosis were evaluated by US. Of the 166 children, 107 were diagnosed with hepatic steatosis by US, 46 with grade I, 56 with grade II, and five children with grade III. According to the grade of hepatic steasosis, the average values of midline abdominal subcutaneous fat thickness and right flank abdominal subcutaneous fat thickness measured 2.9±0.8 cm and 1.9±0.7 cm in the normal group, 3.3±0.8 cm and 2.0±0.7 cm in grade I, 3.8±0.8 cm and 2.3±0.8 cm in grade II, and 4.1±0.8 cm and 2.8±1.4 cm in grade III, respectively. Abdominal subcutaneous fat thickness correlated with grade of hepatic steatosis (pabdominal subcutaneous fat thickness correlated with concentration of serum lipids and liver transaminases in the age group of 12-14 years (pAbdominal subcutaneous fat thickness measured by US can be used as a reliable predictor of possible hyperlipidemia and steatohepatitis in children, especially during the adolescent stage.

  7. DNABIT Compress – Genome compression algorithm

    OpenAIRE

    Rajarajeswari, Pothuraju; Apparao, Allam

    2011-01-01

    Data compression is concerned with how information is organized in data. Efficient storage means removal of redundancy from the data being stored in the DNA molecule. Data compression algorithms remove redundancy and are used to understand biologically important molecules. We present a compression algorithm, “DNABIT Compress” for DNA sequences based on a novel algorithm of assigning binary bits for smaller segments of DNA bases to compress both repetitive and non repetitive DNA sequence. Our ...

  8. DNABIT Compress – Genome compression algorithm

    Science.gov (United States)

    Rajarajeswari, Pothuraju; Apparao, Allam

    2011-01-01

    Data compression is concerned with how information is organized in data. Efficient storage means removal of redundancy from the data being stored in the DNA molecule. Data compression algorithms remove redundancy and are used to understand biologically important molecules. We present a compression algorithm, “DNABIT Compress” for DNA sequences based on a novel algorithm of assigning binary bits for smaller segments of DNA bases to compress both repetitive and non repetitive DNA sequence. Our proposed algorithm achieves the best compression ratio for DNA sequences for larger genome. Significantly better compression results show that “DNABIT Compress” algorithm is the best among the remaining compression algorithms. While achieving the best compression ratios for DNA sequences (Genomes),our new DNABIT Compress algorithm significantly improves the running time of all previous DNA compression programs. Assigning binary bits (Unique BIT CODE) for (Exact Repeats, Reverse Repeats) fragments of DNA sequence is also a unique concept introduced in this algorithm for the first time in DNA compression. This proposed new algorithm could achieve the best compression ratio as much as 1.58 bits/bases where the existing best methods could not achieve a ratio less than 1.72 bits/bases. PMID:21383923

  9. Meaning of ureter dilatation during ultrasonography in infants for evaluating vesicoureteral reflux

    Energy Technology Data Exchange (ETDEWEB)

    Park, Yae-won, E-mail: yaewonpark@yuhs.ac [Department of Radiology and Research Institute of Radiological Science, Severance Children' s Hospital, Yonsei University College of Medicine, 120-752 Seoul (Korea, Republic of); Kim, Myung-Joon, E-mail: mjkim@yuhs.ac [Department of Radiology and Research Institute of Radiological Science, Severance Children' s Hospital, Yonsei University College of Medicine, 120-752 Seoul (Korea, Republic of); Han, Sang Won, E-mail: swhan58@yuhs.ac [Department of Pediatric Urology, Severance Children' s Hospital, Yonsei University College of Medicine, 120-752 Seoul (Korea, Republic of); Kim, Dong Wook, E-mail: kimdw@yuhs.ac [Biostatistics Collaboration Unit, Yonsei University, College of Medicine, 120-752 Seoul (Korea, Republic of); Lee, Mi-Jung, E-mail: mjl1213@yuhs.ac [Department of Radiology and Research Institute of Radiological Science, Severance Children' s Hospital, Yonsei University College of Medicine, 120-752 Seoul (Korea, Republic of)

    2015-02-15

    Purpose: To investigate the meaning of ureter dilatation during ultrasonography (US) in infants for evaluating vesicoureteral reflux (VUR). Materials and methods: We retrospectively reviewed abdominal US images of infants who were diagnosed with urinary tract infection (UTI group) or only hydronephrosis without UTI (control group). Hydronephrosis (graded 0–4) and ureter dilatation (present or absent) were evaluated on each side with US. Voiding cystourethrography (VCUG) within 3 months time interval with US was also reviewed and VUR was graded (0–5) on each side. Hydronephrosis, ureter dilatation, and VUR were then compared between the two groups. Results: Four hundred and three infants (142 in the UTI group and 261 in the control group) were included and VCUG was performed in 129 infants (68 in UTI and 61 in control groups). VUR grades were not different between the two groups (p = 0.252). Hydronephrosis grade was not related to VUR in either group (p > 0.05). However, ureter dilatation had a significant relationship with VUR in the UTI group (p = 0.015), even among patients with a high-grade VUR (p = 0.005). Whereas, ureter dilatation was not associated with VUR in the control group (p = 0.744). The relationship between ureter dilatation and VUR was different between the two groups for both all grades (p = 0.014) and high-grade (p = 0.004) VUR. Ureter dilatation had 66.7% sensitivity, 80.3% specificity, and 79.4% accuracy for evaluating high-grade VUR in the UTI group. Conclusion: Ureter dilatation on US can be a helpful finding for detecting VUR in infants with UTI, but not infants without UTI.

  10. Meaning of ureter dilatation during ultrasonography in infants for evaluating vesicoureteral reflux

    International Nuclear Information System (INIS)

    Park, Yae-won; Kim, Myung-Joon; Han, Sang Won; Kim, Dong Wook; Lee, Mi-Jung

    2015-01-01

    Purpose: To investigate the meaning of ureter dilatation during ultrasonography (US) in infants for evaluating vesicoureteral reflux (VUR). Materials and methods: We retrospectively reviewed abdominal US images of infants who were diagnosed with urinary tract infection (UTI group) or only hydronephrosis without UTI (control group). Hydronephrosis (graded 0–4) and ureter dilatation (present or absent) were evaluated on each side with US. Voiding cystourethrography (VCUG) within 3 months time interval with US was also reviewed and VUR was graded (0–5) on each side. Hydronephrosis, ureter dilatation, and VUR were then compared between the two groups. Results: Four hundred and three infants (142 in the UTI group and 261 in the control group) were included and VCUG was performed in 129 infants (68 in UTI and 61 in control groups). VUR grades were not different between the two groups (p = 0.252). Hydronephrosis grade was not related to VUR in either group (p > 0.05). However, ureter dilatation had a significant relationship with VUR in the UTI group (p = 0.015), even among patients with a high-grade VUR (p = 0.005). Whereas, ureter dilatation was not associated with VUR in the control group (p = 0.744). The relationship between ureter dilatation and VUR was different between the two groups for both all grades (p = 0.014) and high-grade (p = 0.004) VUR. Ureter dilatation had 66.7% sensitivity, 80.3% specificity, and 79.4% accuracy for evaluating high-grade VUR in the UTI group. Conclusion: Ureter dilatation on US can be a helpful finding for detecting VUR in infants with UTI, but not infants without UTI

  11. Value of ultrasonography in the differential diagnosis of appendicitis

    International Nuclear Information System (INIS)

    Alonso, J.M.; Sandoval, E.

    1998-01-01

    To determine the utility of ultrasound in the diagnosis of diseases that can be confused with appendicitis or presenting with atypical clinical signs of appendiceal inflammation. Graded-compression ultrasound was performed in 226 patients presenting with pain in right iliac fossa. Twenty-three patients were excluded because of inconclusive examination. Appendicitis was confirmed intraoperatively in 98 cases. There was no appendiceal inflammation in 105 patients. A final diagnosis could not be reached in 26 cases (4.7%) and was considered to represent abdominal pain of unknown origin. Ultrasound provided the correct diagnosis in 72 of the 79 patients in whom a definitive diagnosis was reached (91.1%). A wide spectrum of pathologies was identified by ultrasound, including gastrointestinal complaints (n=51), gynecological disorders (n=10), bioliopancreatic abnormalities (n=4), urological diseases (n=3) and others (n=3). Ultrasound is useful in the differential diagnosis of patients with confusing clinical signs of appendicitis. (Author) 34 refs

  12. Normal values for quantitative muscle ultrasonography in adults.

    NARCIS (Netherlands)

    Arts, I.M.P.; Pillen, S.; Schelhaas, H.J.; Overeem, S.; Zwarts, M.J.

    2010-01-01

    Ultrasonography can detect structural muscle changes caused by neuromuscular disease. Quantitative analysis is the preferred method to determine if ultrasound findings are within normal limits, but normative data are incomplete. The purpose of this study was to provide normative muscle

  13. Ultrasonography as a diagnostic method in addition to mammography

    Energy Technology Data Exchange (ETDEWEB)

    Otto, H.; Roer, E.

    1988-05-01

    By using ultrasonography in addition to mammography, experienced diagnosticians essentially enhance the safety of their diagnosis of mammary gland diseases. The same applies to gynecomastia, the condition after plastic surgery, and mastitis.

  14. Ultrasonography as a better diagnostic efficiency in rib fracture

    OpenAIRE

    UZUN, Metin; BEKSAÇ, Burak; KARATAŞ, Adnan; KÜÇÜKDURMAZ, Fatih; KIRCALI, Bahar ANAYURDU; TETİK, Cihangir

    2013-01-01

    In this study, our aim was to demonstrate the need of use of ultrasonography in rib fractures in order not to face medicolegal problems. One hundred patients admitted to our emergency service with mild to moderate blunt thorax trauma were included in our study prospectively. The inclusion criteria were pain upon palpation of ribs, deep inspiration, coughing but no any other pathologies like a pneumothorax, hemothorax. All patients are evaluated with ultrasonography (USG) and direct X-rays. X-...

  15. Ultrasonography of the lower extremity veins: Anatomy and basic approach

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Dong Kyu; Ahn, Kyung Sik; Kang, Chang Ho; Cho, Sung Bum [Dept. of Radiology, Korea University Anam Hospital, Korea University College of Medicine, Seoul (Korea, Republic of)

    2017-04-15

    Ultrasonography is an imaging modality widely used to evaluate venous diseases of the lower extremities. It is important to understand the normal venous anatomy of the lower extremities, which has deep, superficial, and perforating venous components, in order to determine the pathophysiology of venous disease. This review provides a basic description of the anatomy of the lower extremity veins and useful techniques for approaching each vein via ultrasonography.

  16. Intraoperative ultrasonography in detection of hepatic metastases from colorectal cancer

    DEFF Research Database (Denmark)

    Rafaelsen, Søren Rafael; Kronborg, Ole; Fenger, Claus

    1995-01-01

    PURPOSE: This study was designed to compare diagnostic accuracies of measuring liver enzymes, preoperative ultrasonography, surgical examination, and intraoperative ultrasonography for detection of liver metastases from colorectal cancer. METHODS: Blind, prospective comparisons of diagnostic...... examinations mentioned above were performed in 295 consecutive patients with colorectal cancer. An experienced ultrasonologist performed the preoperative examinations, and results were unknown to the other experienced ultrasonologist who performed the intraoperative examinations. The latter, also was unaware...

  17. Ultrasonography of the lower extremity veins: Anatomy and basic approach

    International Nuclear Information System (INIS)

    Lee, Dong Kyu; Ahn, Kyung Sik; Kang, Chang Ho; Cho, Sung Bum

    2017-01-01

    Ultrasonography is an imaging modality widely used to evaluate venous diseases of the lower extremities. It is important to understand the normal venous anatomy of the lower extremities, which has deep, superficial, and perforating venous components, in order to determine the pathophysiology of venous disease. This review provides a basic description of the anatomy of the lower extremity veins and useful techniques for approaching each vein via ultrasonography

  18. Acute diverticulitis of the terminal ileum: ultrasonography and CT findings

    Energy Technology Data Exchange (ETDEWEB)

    Jeong, Jewon; Hong, Seong Sook; Hwang, Ji Young; Kim, Hyun Joo; Chang, Yun Woo [Dept. of Radiology, Soonchunhyang University Seoul Hospital, Soonchunhyang University College of Medicine, Seoul (Korea, Republic of)

    2015-01-15

    We describe a rare case of terminal ileal diverticulitis in a 68-year-old female with a day of history Epub ahead of print of right lower quadrant pain and tenderness, mimicking acute appendicitis. Ultrasonography revealed small sac-like out-pouching lesions with increased echogenicity of surrounding fat in thickened terminal ileum, suggesting inflamed diverticula. We diagnosed terminal ileal diverticulitis primarily by ultrasonography. The diagnosis was confirmed by subsequent computed tomography.

  19. New endoscopic ultrasonography techniques for pancreticobiliary diseases

    Energy Technology Data Exchange (ETDEWEB)

    Kamata, Ken; Kitano, Masayuki; Omoto, Shunsuke; Kadosaka, Kumpei; Miyata, Takeshi; Minaga, Kosuke; Yamao, Kentaro; Imai, Hajime; Kudo, Masatoshii [Dept. of Gastroenterology and Hepatology, Kinki University Faculty of Medicine, Osaka (Japan)

    2016-07-15

    Endoscopic ultrasonography (EUS) is widely used to evaluate pancreaticobiliary diseases, especially pancreatic masses. EUS has a good ability to detect pancreatic masses, but it is not sufficient for the differential diagnosis of various types of lesions. In order to address the limitations of EUS, new techniques have been developed to improve the characterization of the lesions detected by EUS. EUS-guided fine needle aspiration (EUS-FNA) has been used for diagnosing pancreatic tumors. In order to improve the histological diagnostic yield, a EUS-FNA needle with a core trap has recently been developed. Contrast-enhanced harmonic EUS is a new imaging modality that uses an ultrasonographic contrast agent to visualize blood flow in fine vessels. This technique is useful in the diagnosis of pancreatic solid lesions and in confirming the presence of vascularity in mural nodules for cystic lesions. EUS elastography analyzes several different variables to measure tissue elasticity, color patterns, and strain ratio, using analytical techniques such as hue-histogram analysis, and artificial neural networks, which are useful for the diagnosis of chronic pancreatitis and pancreatic cancer.

  20. Rupture of Achilles Tendon : Usefulness of Ultrasonography

    International Nuclear Information System (INIS)

    Kim, Nam Hyeon; Ki, Won Woo; Yoon, Kwon Ha; Kim, Song Mun; Shin, Myeong Jin; Kwon, Soon Tae

    1996-01-01

    To differentiate a complete rupture of Achilles tendon from an incomplete one which is important because its treatment is quite different. And it is necessary to know the exact site of the rupture preoperatively. Fifteen cases of fourteen patients which were diagnosed as Achilles tendon rupture by ultrasonography and surgery were reviewed. We compared sonographic rupture site with surgical findings. Ultrasonographic criteria for differentiation of complete and incomplete rupture was defined as follows : the discreteness, which means the proximal intervening hypoechogenicity to the interface echogenicity of distal margin of ruptured tendon : the slant sign, which represents the interface of ruptured distal margin which was seen over the 3/4 of the thickness of the tendon without intervening low echogeneicity : the invagination sign, which means the echogenic invagination from Kager triangle into posterior aspect of Achilles tendon over the half thickness of the tendon. The sites of complete tendon rupture were exactly corresponded to surgical finding in four cases of ten complete ruptures. And the discrepancy between sonographic and surgical findings in the site of complete rupture was 1.2 ± 0.4 cm in six cases. Three of ten complete ruptures showed the discreteness sign, all of ten showed the slant sign and two of ten showed the invagination sign. It is helpful to differentiate a complete from incomplete rupture of the Achilles tendon and to localize the site of the complete rupture with the ultrasonographic evaluation

  1. Ultrasonography of hydronephrosis and renal masses

    International Nuclear Information System (INIS)

    Lee, Kyung Weon; Kim, Chong Gun; Kim, Yeon Jin; Rhee, Byung Chull

    1984-01-01

    We have analyzed ultrasonographic findings of 55 cases of hydronephrosis and 34 cases of renal masses. The results are as follows: 1. 55 cases of hydronephrosis revealed renal enlargement in 55 cases, separation of central echo complex in 27 cases, multiple anechoic areas radiating from the center in 25 cases and dilated renal pelvis in 24 cases. 2. Among the masses in 34 cases, simple renal cyst were 15 cases, polycystic kidney in 8 cases, hypernephroma in 8 cases, Wilm's tumor in 2 cases and agiomyolipoma in 1 case. 3. Simple renal cyst revealed single in 14 cases (93%) and well defined anechoic mass with posterior enhancement in all cases. 4. Polycystic kidney revealed bilateral irregular shaped renal enlargement and multiple anechoic cysts throughout the kidney. 2 cases (25%) involved liver. 5. 6 cases (75%) of hypernephroma revealed ill defined moderately echogenic mass without posterior enhancement. 6. All cases of Wilm's tumor revealed well defined large mixed echogenic mass in right kidney. 7. Angiomyolipoma revealed bilateral dense echogenic mass with large hemorrhage cyst in right kidney. 8. The ultrasonography is useful noninvasive diagnostic modality of evaluation of renal masses and hydronephrosis.

  2. En bloc kidney transplantation: ultrasonography assessment

    International Nuclear Information System (INIS)

    Arenal, F.; Ganado, T.; Merino, M.S.; Contreras, E.; Hernandez, J.; Prats, D.

    1997-01-01

    The objective of our study is to assess the utility of ultrasonography in the study of the complications associated with en bloc kidney transplantation. Twenty-three recipients of double transplants from donors under the age of 3 years were studied. Ultrasound (mode B: pulsed Doppler and color Doppler) was performed within the first three postoperative days and was repeated at 6 and 12 months. The morphology of the graft and renal blood flow were assessed, and the indices of pulsatility, resistance and acceleration were measured. Four patients required graft explanation: three due to massive hemorrhagic infarction and one due to venous thrombosis. Vascular complications were detected in five transplants (21.7%), urological complications in four (17.4%) and medical complications in two (8.7%). The most common vascular complication was unilateral renal artery stenosis. Color Doppler ultrasound diagnosed all the medical and urological complications and three of the five cases of vascular pathology (60%). Renal size was seen to be increased during the first postoperative year. The ultrasonographic study is more difficult to perform in en bloc kidney transplantation than in single kidney grafting: however, given its marked sensitivity in the detection of postransplantation complications. Doppler ultrasound is the imaging technique of choice in the determination of the cause of deteriorated kidney function. (Author) 15 refs

  3. Identification of intraluminal thrombus by ultrasonography in emergency department patients with acute deep venous thrombosis.

    Science.gov (United States)

    Mehta, Ninfa; Schecter, Joshua; Stone, Michael

    2012-05-01

    Traditionally, the diagnosis of deep venous thrombosis (DVT) using duplex ultrasonography (DU) has relied on the absence of venous compressibility. Visualization of an intraluminal thrombus is considered an uncommon finding. The purpose of this study is to determine the frequency of intraluminal thrombus in emergency department (ED) patients diagnosed with acute DVT. Retrospective chart review of adult ED patients with DU examinations demonstrating acute DVT. Patients with chronic DVT or patients in whom DU did not demonstrate DVT were excluded from data analysis. Study reports and ultrasound images were reviewed and analyzed for the presence of intraluminal thrombus. There were 189 patients who met inclusion criteria, of which 160 (85%) were found to have intraluminal thrombus. Intraluminal thrombi are present in the majority of patients in our ED in whom acute DVT is identified by DU. Copyright © 2012 Elsevier Inc. All rights reserved.

  4. [Predictive value of ultrasonography in portal hypertension].

    Science.gov (United States)

    Moreno, E; Torres, P; Trejo, C; Barra Ostoni, V; Ortega, C; Römer, H

    1991-01-01

    Portal hypertension is a common pathology in childhood and one of its most common causes is cavernomatosis of the portal vein. This obstruction causes hemodynamic changes which lead to splenomegaly and collateral circulation. Esophageal varices are one of the most important sequelae, which endanger the patient's life because of a bleeding tendency. Ecosonography helps to detect the thickening of the lesser omentum vis a vis the aortic diameter, caused by the collateral circulation. We studied 15 children presenting with portal hypertension resulting from portal vein cavernomatosis; we performed an upper GI endoscopy and abdominal ecosonography. The endoscopy revealed grade II esophageal varices in 20% of cases, the remaining 80% had grade III and grade IV. Ecosonography revealed an increased lesser omentum/aorta ratio in children with portal hypertension, compared to controls (p portal hypertension.

  5. Serial 2-point ultrasonography plus D-Dimer vs whole-leg color-coded doppler ultrasonography for diagnosing suspected symptomatic deep vein thrombosis - A randomized controlled trial

    NARCIS (Netherlands)

    Bernardi, Enrico; Camporese, Giuseppe; Buller, Harry R.; Siragusa, Sergio; Imberti, Davide; Berchio, Arrigo; Ghirarduzzi, Angelo; Verlato, Fabio; Anastasio, Raffaela; Prati, Carolina; Piccioli, Andrea; Pesavento, Raffaele; Bova, Carlo; Maltempi, Patrizia; Zanatta, Nello; Cogo, Alberto; Cappelli, Roberto; Bucherini, Eugenio; Cuppini, Stefano; Noventa, Franco; Prandoni, Paolo

    2008-01-01

    Context Patients with suspected deep vein thrombosis ( DVT) of the lower extremities are usually investigated with ultrasonography either by the proximal veins ( 2-point ultrasonography) or the entire deep vein system ( whole- leg ultrasonography). The latter approach is thought to be better based

  6. Granulomatous Prostatitis: Gray-scale Transrectal Ultrasonography and Color Doppler Ultrasonography Findings

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Hyoung Jung; Lim, Joo Won; Lee, Dong Ho; Ko, Young Tae; Kim, Eui Jong [Kyung Hee University Medical Center, Seoul (Korea, Republic of)

    2007-12-15

    We report here three cases of granulomatous prostatitis. All cases were confirmed by a transrectal ultrasonography (TRUS)-guided core biopsy of the prostate. Two cases received intravesical BCG therapy for a bladder tumor, and one case had no known predisposing condition. Gray-scale TRUS showed low echoic nodules in the outer gland in all cases. Color Doppler ultrasonography (CDUS) showed several dot-like blood flows within the low echoic nodules in two cases and several dot-like blood flows and short linear blood flows within the low echoic nodules in one case. Gray-scale TRUS findings of granulomatous prostatitis are similar to findings of prostate cancer. On CDUS, several dot-like blood flows or short linear blood flows were noted within the low echoic nodules in patients with granulomatous prostatitis. If low echoic nodules with dot-like or short linear blood flows are noted in patients with genitourinary tract tuberculosis or previous BCG therapy, granulomatous prostatitis should be included in the differential diagnosis. However, a prostatic biopsy is required for a final diagnosis

  7. MP3 compression of Doppler ultrasound signals.

    Science.gov (United States)

    Poepping, Tamie L; Gill, Jeremy; Fenster, Aaron; Holdsworth, David W

    2003-01-01

    The effect of lossy, MP3 compression on spectral parameters derived from Doppler ultrasound (US) signals was investigated. Compression was tested on signals acquired from two sources: 1. phase quadrature and 2. stereo audio directional output. A total of 11, 10-s acquisitions of Doppler US signal were collected from each source at three sites in a flow phantom. Doppler signals were digitized at 44.1 kHz and compressed using four grades of MP3 compression (in kilobits per second, kbps; compression ratios in brackets): 1400 kbps (uncompressed), 128 kbps (11:1), 64 kbps (22:1) and 32 kbps (44:1). Doppler spectra were characterized by peak velocity, mean velocity, spectral width, integrated power and ratio of spectral power between negative and positive velocities. The results suggest that MP3 compression on digital Doppler US signals is feasible at 128 kbps, with a resulting 11:1 compression ratio, without compromising clinically relevant information. Higher compression ratios led to significant differences for both signal sources when compared with the uncompressed signals. Copyright 2003 World Federation for Ultrasound in Medicine & Biology

  8. The Role of Color Doppler Ultrasonography in Characterization of Thyroid Tumors

    International Nuclear Information System (INIS)

    Kim, Hee Soo; Jeon, Pyong; Won, Jong Yoon; Na, Jae Beom; Lee, Hyang Mee; Yoo, Hyung Sik; Lee, Jong Tae; Park, Jeong Soo; Cho, Nam Hoon

    1995-01-01

    To assess the usefulness of color Doppler ultrasonography in the characterization of thyroid tumors, surgically proven 88 nodules in 85 patients were evaluated. Using 10 MHz linear array transducer, gray scale images were initially evaluated. Then, distribution pattern of color signals (marginal, intra-tumoral, mixed) and graded internal vascularity according to morphology of color signal (0:absence of internal signal, 1: spotty, 2: linear,3: branching) were observed on color doppler imaging. Pulsed doppler waves were analyzed with parameters including peak systolic velocity(PSV), resistive index(RI), and pulsatile index(PI). Significantly larger numbers of intra-tumoral type, 20 cases(62.5%), were observed in malignant nodules, whereas mixed forms were predominant in benign group, 37 cases (66%) In graded internal vascularity, malignant nodules tended to have grade 2 or 3 signals, whereas benign nodules tended to have grade 0 or 1 signals. Spectral wave analysis show no significant difference in the value of PSV, RI, and PI between malignancy and benignity group. In conclusion, color Doppler imaging has a potential role in the characterization of thyroid nodules as a supportive method for gray scale diagnosis

  9. An analysis of 1018 cases of ultrasonography

    International Nuclear Information System (INIS)

    Kim, Chu Wan; Suh, Jeong Soo; Lee, Kwan Seh; Kim, Ki Hwan; Im, Chung Gie; Chang, Kee Hyun; Yeon, Kyung Mo; Han, Man Chung; Choo, Dong Woon

    1985-01-01

    Ultrasound is an especially helpful diagnostic tool in assessing various diseases in various organs as well as differentiating cystic masses from solid ones, with ease safety, reproducibility, and high accuracy. Authors analyzed total 1018 cases of ultrasonography that were studied in last seven months from March. 15. 1979 to October. 31. 1979, at the Department of Radiology, Seoul National University Hospital. The results were as follows: 1. Among the 1018 cases, 421 cases were male and 597 cases of female. The age distribution was from several months to 83 years, and 88% of all cases were in 20 to 69 years of age. 2. Sites of scanning; Liver, G.B. and biliary systems 376, thyroid 185, kidney 192, pelvis 121, abdomen 70, pancreas 48, eyeball 14, and other 12. 3. Hepatobiliary system 376; Normal 174, hepatomegaly 12, hepatoma 7, metastases 6, abscess 6, cirrhosis 2, hepatic cyst 1, hemangioma 1, agenesis of left lobe 1. 4. G.B. stones 106, cholecystitis 35, biliary tree dilatation 13, enlarged G.B. 7, C.B.D. stone 5, cystic duct stone 4, C.B.D. cancer 6, G.B. cancer 1, choledochal cyst 1, non-visualized G.B. 8. 5. Thyroid, 185; Nodule 147 -- solid 56, cystic 70, complex 21, Diffuse enlargement 29, normal scan 7, unidentified 2. 6. Pancreas, 48; Normal 17, pancreastitis 4, pancreatic cancer 22, pseudocyst 4, unidentified 1. 7. Abdomen 77 (excluding liver, G.B. and pancreas); Normal scan 31, solid tumor 14 - lymphoma group 12, mesenchyma origin 2, multiple lymph node enlargement 13, aortic aneurysm 4, retroperitoneal mass 2, subphrenic abscess 2, abdominal wall abscess 2, unknown solid mass 4, not contributory 4. 8. Kidney, 194, Normal scan 44, size and markings for biopsy 75, hydronephrosis 21, renal cyst 8, polycystic disease 8, solid renal tumor 10, renal stone 7, agenesis or hypoplasia 2, contracted kidney, both 7, enlarge kidney due to lymphoma and compensatory hyperplasia 5, renal tbc 2, perirenal abscess 1, perirenal hematoma 1, movable kidney 1, bladder tumor

  10. Endoscopic ultrasonography-guided rendezvous technique.

    Science.gov (United States)

    Tsuchiya, Takayoshi; Itoi, Takao; Sofuni, Atsushi; Tonozuka, Ryosuke; Mukai, Shuntaro

    2016-04-01

    Endoscopic retrograde cholangiopancreatography (ERCP) requires deep biliary cannulation. When deep biliary cannulation is failed, the endoscopic ultrasonography rendezvous technique (EUS-RV) is a useful salvage method. From the previous 15 articles that included 382 EUS-RV cases, the overall success rate of EUS-RV is 81 % with a complication rate of 10 %. In EUS-RV, the bile duct is punctured under EUS guidance and a guidewire is advanced into the duodenum via the papilla. The EUS scope is then switched to a duodenoscope and inserted into the bile duct over the guidewire exiting the papilla, or the guidewire is grasped with forceps and passed through the working channel; the catheter can then be inserted through the papilla over the wire. There are three puncture routes for EUS-RV: transgastric puncture of the intrahepatic bile duct (IHBD), transduodenal puncture of the extrahepatic bile duct (EHBD) via the proximal duodenum (D1), and transduodenal puncture of the EHBD via the second portion of the duodenum (D2). The puncture route for each patient should be selected based on the patient condition. GW selection for EUS-RV is critical, a hydrophilic GW is useful for this procedure. Although EUS-RV is now performed relatively routinely in a few high-volume centers, procedure standardization and the development of exclusive devices for EUS-RV are still underway. The development of exclusive devices for EUS-RV and prospective comparative studies with other salvage methods are needed to truly evaluate the procedure's usefulness and safety.

  11. Evaluation of Snake Bites with Bedside Ultrasonography

    Directory of Open Access Journals (Sweden)

    Josef E Jolissaint

    2018-04-01

    Full Text Available History of present illness: While watering his lawn, a 36-year-old man felt two sharp bites to his bilateral ankles. He reports that he then saw a light brown, 2-foot snake slither away from him. He came to the emergency department because of pain and swelling in his ankles and inability to bear weight. Physical examination revealed bilateral ankle swelling and puncture marks on his left lateral heel and medial right ankle. Palpation, passive flexion and extension elicited severe pain bilaterally. Blood work including prothrombin time (PT, partial thromboplastin time (PTT, international normalized ratio (INR, and fibrinogen were within normal limits. Consultation with Poison Control indicated the snake was likely a copperhead, which is a venomous snake whose bites rarely require antivenin. Significant findings: In this case, ultrasonography of the lateral surface of the left foot revealed soft tissue edema (red arrow and fluid collection (white asterisk adjacent to the extensor tendon (white arrow. The edematous area resembles cobblestones, with hypoechoic areas of fluid spanning relatively hyperechoic fat lobules. The tendon is surrounded by anechoic fluid, expanding the potential space in the sheath. No hyperechoic foreign objects were noted. Discussion: The patient was diagnosed with soft tissue injury and extensor tenosynovitis after a snake envenomation. Snake venom contains metalloproteinases and other enzymatic proteins that cause local tissue edema and necrosis.1 After a snake bite, ultrasound can be used to assess for retained fangs, soft tissue edema, tendon sheath fluid, muscle fasciculation, and injury to deeper musculature that may not be readily apparent on physical exam.2,3 Most patients with tenosynovitis will recover with immobilization of the joint and non-steroidal anti-inflammatory medications.4 Rarely, the tendon may become infected requiring antibiotics and surgical intervention.4 Topics: Ultrasound, snake envenomation

  12. Ultrasonography in Gastroenterology: The Need for Training

    Directory of Open Access Journals (Sweden)

    João Pinto

    2018-02-01

    Full Text Available The use of ultrasonography (US as an imaging modality in medicine has spread across almost every clinical specialty. This diffusion is based on the simplicity, accessibility, portability and affordability of the technique producing real-time high-resolution images using non-ionising radiation. On the other hand, this trend also extended the technique to settings other than healthcare, such as public facilities, private houses or remote sites. This tendency can be observed worldwide, from developing countries to prestigious medical schools and tertiary referral hospitals. Furthermore, point-of-care US (POCUS, i.e., US executed at the patient’s bedside to obtain real-time objective information with diagnostic and clinical monitoring purposes or to guide invasive procedures, has been incorporated in many specialties. In gastroenterology, despite the essential role of endoscopy, clinical practice is highly dependent on non-endoscopic imaging techniques. However, as in other specialties, the indications of US in gastroenterology have been increasing steadily, covering a broad range of conditions. In response to the generalised employment of US by non-radiologists, institutions such as the European Federation of Societies for Ultrasound in Medicine and Biology and the Royal College of Radiologists issued recommendations to ensure high-quality practice. These theoretical and practical requisites include performing a certain number of examinations and mandatory skills in order to achieve certification to execute unsupervised US. Therefore, there is a need for modern gastroenterology to include US as a basic skill in its clinical practice. To ensure the provision of high-quality US, adequate instruction of future specialists should be guaranteed by the gastroenterology departments and required in the residency training programme.

  13. Evaluation of normal masseter muscles on ultrasonography

    International Nuclear Information System (INIS)

    Hwang, Hyoung Zoo; Kim, Gyu Tae; Choi, Yong Suk; Hwang, Eui Hwan

    2008-01-01

    To assess the internal echo intensity and morphological variability of masseter muscles on ultrasonography and to establish diagnostic criterion of estimation. Participants consisted of 50 young adults (male 25, female 25) without pathologic conditions and with full natural dentitions. Sonographic examinations were done with real time ultrasound equipment as Logiq 500 (GE Medical Systems, Seoul, Korea) at 3 parts according to lines paralleling with ala-tragus line as reference line. The thickness and area of masseter muscles according to reference line in cross-sectional images were measured at rest and at maximum contraction. The visibility and width of the internal echogenic intensity of the masseter muscles were also assessed and the muscle appearance was classified into 4 types. Data were statistically analyzed by paired t-test and x2-test. 1. When comparing the thickness and area of masseter muscles concerning with gender, there was few significant difference between right and left sides, however, there were significant differences between males and females except for the greatest thickness of left side. 2. The changes of the greatest thickness and the area between rest and maximum contraction showed that the part of the least thickness manifested more increase at maximum contraction. 3. Each part the manifestations of the internal echogenic intensity of the masseter muscles were different depending on the locations. But there was no statistically significance. Changes of muscles thickness with contraction and internal echogenic intensity with locations showed great disparity within the masseter muscles, which will be diagnostic criteria for pathophysiologic and anatomic changes of masseter muscles.

  14. Transvaginal ultrasonography in first trimester of pregnancy and its comparison with transabdominal ultrasonography

    Directory of Open Access Journals (Sweden)

    Aneet Kaur

    2011-01-01

    Full Text Available Objectives : Examination of pregnant women in the first trimester with transvaginal ultrasonography with the aim to study various fetal development markers, e.g., gestation sac, yolk sac, fetal heart motion, CRL length, and fetal anatomy in both normal and abnormal pregnancies. Comparative evaluation of transvaginal ultrasonography vis-ΰ-vis transabdominal scanning in the study of first trimester of pregnancy and its complications. To assess the relative merits and demerits of transvaginal ultrasonography in comparison with the transabdominal technique. Materials and Methods : The study will be conducted on 50 females patients during the first trimester of pregnancy. The study population will consist of both normal and abnormal pregnancies. These patients will be included on the basis of suspicion of or proven pregnancy of duration up to 12 weeks from LMP. The evaluation of the patients will include the following: Record of patients obstetrical history and clinical examination, record of pregnancy test and relevant investigations, ultrasonic examination of pregnancy. (a Transabdominal ultrasound scanning will be done with moderately distended bladder by using real time scanners with low frequency probe (3/3.5 MHz; (b transvaginal sonography will be done with the real-time sector scanner using high-frequency endovaginal probe (5/7.5 MHz, after the patient voids urine. Relevant images will be taken by using the multiformat automatic camera. Results and Conclusions : In the study of 46 normal intrauterine pregnancies, TVS showed additional information in 36 patients (78.3% as compared to TAS, in detection of gestation sac, yolk sac, double bleb sign, or better visualization of embryonic anatomy. In the abnormal pregnancy (n=17, TVS provided more information in 11 cases (64.9%, which included detection of embryonic demise, yolk sac, double bleb sign, or subchorionic hemorrhage. Regarding ectopic gestations (n=7, TVS gave additional information in 5

  15. Evaluation of abdominal trauma by computed tomography and ultrasonography

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Do Yun; Kim, Sang Jin; Lee, Jong Tae; Yoo, Hyung Sik [Yonsei University College of Medicine, Seoul (Korea, Republic of)

    1986-06-15

    Out of 75 patients who were admitted to our hospital because of abdominal trauma and were undergone the procedures such as ultrasonography and/or CT scan within 24 hours of abdominal trauma due to suspected abdominal organ injury. We analyzed the results of 38 patients who were confirmed of diagnosis by operation, follow-up CT scan or ultrasonography. We analyzed the results of 38 patients who were confirmed of diagnosis by operation, follow-up CT scan or ultrasonography. 1. In the abdominal organ injury, solid organ injury consists of 8 cases of spleen laceration, 1 of splenic subcapsular hematoma, 7 of hepatic laceration, 7 of pancreas laceration, 3 of renal laceration, and 3 of subcapsular hematoma of kidney. 2. In addition, there were 7 bowel and/or mesenteric laceration, 2 diaphragmatic hernia, and 1 urethral rupture. 3. 2 cases of retroperitoneal hematoma and 1 case in which hemo peritoneum occurred without abdominal organ injury were confirmed by follow-up CT or ultrasonography. 4. In all of the 4 patients with multiple organ injury, pancreatic laceration was associated. 5. In abdominal trauma patients, ultrasonography or CT can be used to survey rapidly the entire abdomen for possible associated injury, and be of great help to clinicians in identifying the patients who need immediate surgery or in minimizing the incidence of unnecessary emergency abdominal exploration.

  16. Evaluation of abdominal trauma by computed tomography and ultrasonography

    International Nuclear Information System (INIS)

    Lee, Do Yun; Kim, Sang Jin; Lee, Jong Tae; Yoo, Hyung Sik

    1986-01-01

    Out of 75 patients who were admitted to our hospital because of abdominal trauma and were undergone the procedures such as ultrasonography and/or CT scan within 24 hours of abdominal trauma due to suspected abdominal organ injury. We analyzed the results of 38 patients who were confirmed of diagnosis by operation, follow-up CT scan or ultrasonography. We analyzed the results of 38 patients who were confirmed of diagnosis by operation, follow-up CT scan or ultrasonography. 1. In the abdominal organ injury, solid organ injury consists of 8 cases of spleen laceration, 1 of splenic subcapsular hematoma, 7 of hepatic laceration, 7 of pancreas laceration, 3 of renal laceration, and 3 of subcapsular hematoma of kidney. 2. In addition, there were 7 bowel and/or mesenteric laceration, 2 diaphragmatic hernia, and 1 urethral rupture. 3. 2 cases of retroperitoneal hematoma and 1 case in which hemo peritoneum occurred without abdominal organ injury were confirmed by follow-up CT or ultrasonography. 4. In all of the 4 patients with multiple organ injury, pancreatic laceration was associated. 5. In abdominal trauma patients, ultrasonography or CT can be used to survey rapidly the entire abdomen for possible associated injury, and be of great help to clinicians in identifying the patients who need immediate surgery or in minimizing the incidence of unnecessary emergency abdominal exploration.

  17. Evaluation of breast symptoms with mammography and ultrasonography

    Directory of Open Access Journals (Sweden)

    Emine Devolli Disha

    2011-12-01

    Full Text Available Introduction: Aim of the study was to discern which are more frequent symptoms presented in malign and benign masses diagnosed by mammography and ultrasonography.Methods: Our study group consisted of 546 female patients, with breast symptoms such as palpable lumps (40.8%, pain in the breast (26%, localized lumpiness or nodularity (13.7%, nipple retraction (11.2%, nipplebloody discharge (5.1% and redness and swelling of the breast (3.1%. All 546 patients were examined by ultrasonography and mammography. Biopsy was performed according to the findings of mammography and ultrasonography.Results: In breast cancer detection ultrasonography showed an efficiency of 79.4% compared to 55.0% for mammography in detecting breast lump, in the case of nipple retraction mammography showed an efficiency of 89.1% compared to 80.4% for ultrasound, while the lowest efficiency for mammography was in the cases with localized lumpiness or nodularity 17.1% compared to 45.7% for ultrasound. In detecting fibrocystic changes where the most common symptoms was pain, ultrasonography showed an efficiency of 99.3 % compared to 84.2 % for mammography.Conclusions: Our study confirmed that breast lumps are detectable in the majority of patients with breast cancer. The most frequent symptoms in patient with benign lesions were pain or localized discomfort. The diagnostic accuracy for carcinomas of the breast and for benign lesions according to symptoms was higher for ultrasound than for mammography.

  18. Cholescintigraphy and ultrasonography in patients suspected of having acute cholecystitis

    DEFF Research Database (Denmark)

    Lauritsen, K B; Sommer, W; Hahn, L

    1988-01-01

    The diagnostic power of combined cholescintigraphy and ultrasonography was tested in 67 patients suspected of having acute cholecystitis; of these, 42 (63%) had acute cholecystitis. The predictive value of a positive scintigraphy (PVpos) was 95% and that of a negative (PVneg) was 91% (n = 67......). The PVpos and PVneg of ultrasonography were 89% and 75%, respectively (n = 54), and these values did not achieve statistical significance when compared with those for scintigraphy. Inconclusive tests were 10% and 11%, respectively, but in no patient were both scintigraphy and ultrasonography inconclusive...... that in patients suspected of having acute cholecystitis cholescintigraphy should be the first diagnostic procedure performed. If the scintigraphy is positive, additional ultrasonographic detection of gallstones makes the diagnosis almost certain. If one diagnostic modality is inconclusive, the other makes a fair...

  19. Ultrasonography and radiography of the canine postpartum uterus

    International Nuclear Information System (INIS)

    Pharr, J.W.; Post, K.

    1992-01-01

    A vulvovaginal discharge following parturition in a bitch is often a cause of concern to owners and clinicians, especially if whelping was complicated in any way. Ultrasonography could potentially distinguish between normal and abnormal postpartum uterine states because the uterine wall and luminal contents can be imaged in detail. Five normal bitches were examined to determine the normal ultrasonographic appearance of the postpartum uterus and the sensitivity of ultrasonography in detecting the involuting uterus, comparing this sensitivity with that of radiography. Ultrasonography was done at 1, 4, 8, 12, 18 and 24 days postpartum, radiography at 1, 4, 8, 12 and 18 days postpartum. By 12 days postpartum, the uterus could not be seen on radiographs, while at 24 days postpartum the uterus was still sonographically identifiable. The ultrasonographic characteristics of the involuting uterus are described

  20. The diagnostic value of ultrasonography in the gyneocological emergency

    International Nuclear Information System (INIS)

    Su Hui; Chen Fanghua; Peng Xiulan

    2006-01-01

    Objective: To evaluate the ultrasonography in the diagnosis and differential diagnosis of gynecologic emergency. Methods: 138 patients suffered from gynecologic emergency were examined with ultrasonography. The images were retrospectively reviewed and compared with pathologic or clinical results. Results: The total correct diagnostic rate was 89.1%. Among 138 cases of gynecologic emergency, there were 45 cases of ectopic pregnancy, 27 cases of ruptured corpus luteum, 24 cases of torsion of ovarian cyst, and 42 cases of acute pelvic inflammation. The correct diagnostic rates were 91.1%, 81.5%, 87.5%, 92.2%, respectively. Conclusion: The ultrasonography plays an important role in the diagnosis of gynecological emergency. When the US findings were not typical, the clinical history, symptoms and HCG level should be considered in order to avoid misdiagnosis. (authors)

  1. A Compressive Superresolution Display

    KAUST Repository

    Heide, Felix; Gregson, James; Wetzstein, Gordon; Raskar, Ramesh; Heidrich, Wolfgang

    2014-01-01

    In this paper, we introduce a new compressive display architecture for superresolution image presentation that exploits co-design of the optical device configuration and compressive computation. Our display allows for superresolution, HDR, or glasses-free 3D presentation.

  2. A Compressive Superresolution Display

    KAUST Repository

    Heide, Felix

    2014-06-22

    In this paper, we introduce a new compressive display architecture for superresolution image presentation that exploits co-design of the optical device configuration and compressive computation. Our display allows for superresolution, HDR, or glasses-free 3D presentation.

  3. [Abdominal ultrasonography in patients with diabetes mellitus. Part 1: Liver].

    Science.gov (United States)

    Jenssen, C; Pietsch, C; Gottschalk, U; Barreiros, A P; Teufel, A; Cui, X W; Dietrich, C F

    2015-04-01

    In patients with diabetes mellitus, abdominal ultrasonography is the appropriate diagnostic technique to detect and to follow-up secondary and accompanying diseases of the liver, the kidneys, the pancreas, the gastrointestinal tract and of abdominal vessels. Moreover, pancreatic and hepatic diseases may be realized which are of etiological importance for diabetes mellitus. Based on a systematic survey of the published literature, this review in 3 parts will describe the value of abdominal ultrasonography in patients with diabetes mellitus. Part 1 deals with the diagnostic relevance and particular findings of ultrasonographic methods in hepatic manifestations and complications of diabetes mellitus. © Georg Thieme Verlag KG Stuttgart · New York.

  4. Traumatic Lumbar Hernia Diagnosed by Ultrasonography: A Case Report

    International Nuclear Information System (INIS)

    Lee, Kwang Lae; Yim, Yoon Myung; Lim, Oh Kyung; Park, Ki Deok; Choi, Chung Hwan; Lee, Ju Kang

    2009-01-01

    Traumatic lumbar hernia describes the extrusion of intraperitoneal or extraperitoneal contents through a defect in the posterolateral abdominal wall caused by a trauma. This is a rare entity and usually diagnosed by computed tomography. A 64-year-old male received an injury on his cervical spinal cord after an accident in which he fell down. He complained of a mass on his left posterolateral back area. We diagnosed the mass as a traumatic lumbar hernia by ultrasonography and confirmed it by computed tomography. We conclude that the ultrasonography can be a useful diagnostic tool for traumatic lumbar hernia

  5. Traumatic Lumbar Hernia Diagnosed by Ultrasonography: A Case Report

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Kwang Lae; Yim, Yoon Myung; Lim, Oh Kyung; Park, Ki Deok; Choi, Chung Hwan; Lee, Ju Kang [Gachon University of Medicine and Science, Incheon (Korea, Republic of)

    2009-12-15

    Traumatic lumbar hernia describes the extrusion of intraperitoneal or extraperitoneal contents through a defect in the posterolateral abdominal wall caused by a trauma. This is a rare entity and usually diagnosed by computed tomography. A 64-year-old male received an injury on his cervical spinal cord after an accident in which he fell down. He complained of a mass on his left posterolateral back area. We diagnosed the mass as a traumatic lumbar hernia by ultrasonography and confirmed it by computed tomography. We conclude that the ultrasonography can be a useful diagnostic tool for traumatic lumbar hernia

  6. Paediatric ultrasonography of the liver, hepatobiliary tract and pancreas

    Energy Technology Data Exchange (ETDEWEB)

    Rijn, R.R. van, E-mail: r.r.vanrijn@amc.uva.nl [Department of Radiology, Emma Children' s Hospital – Academic Medical Center, Meibergdreef 9, 1105 AZ Amsterdam (Netherlands); Nievelstein, R.A.J. [Department of Radiology, Wilhelmina Children' s Hospital – University Medical Center, Heidelberglaan 100, 3584 CX Utrecht (Netherlands)

    2014-09-15

    In the field of paediatric radiology ultrasonography (US) is the most versatile imaging tool available. Children in general, by virtue of their body composition, are excellent candidates for US exams in whom abdominal anatomy and pathology can be visualised in great detail. The fact that during the US study a clinical history can be obtained strongly adds to the value of the US exam. This does require investment in time and expertise and ideally a paediatric radiologist performing the exam. In this review the role of ultrasonography (US) of the liver, biliary tract and pancreas in children is discussed.

  7. Ultrasonography of hydronephrosis in the newborn: A practical review

    International Nuclear Information System (INIS)

    Choi, Young Hun; Cheon, Jung Eun; Kim, Woo Sun; Kim, In One

    2016-01-01

    Widespread use of fetal ultrasonography is accompanied by more frequent detection of antenatal hydronephrosis. Therefore, sonographic evaluation of neonates with a history of antenatal hydronephrosis is becoming more widespread. As an initial postnatal non-invasive imaging modality, ultrasonography is used to screen for persistence of hydronephrosis, determine the level and severity of obstruction, and contribute to appropriate diagnosis and treatment. This review aims to provide a practical overview of the sonographic evaluation of neonatal hydronephrosis and to describe the sonographic findings of conditions associated with hydronephrosis in the newborn

  8. Ultrasonography of hydronephrosis in the newborn: a practical review

    Science.gov (United States)

    2016-01-01

    Widespread use of fetal ultrasonography is accompanied by more frequent detection of antenatal hydronephrosis. Therefore, sonographic evaluation of neonates with a history of antenatal hydronephrosis is becoming more widespread. As an initial postnatal non-invasive imaging modality, ultrasonography is used to screen for persistence of hydronephrosis, determine the level and severity of obstruction, and contribute to appropriate diagnosis and treatment. This review aims to provide a practical overview of the sonographic evaluation of neonatal hydronephrosis and to describe the sonographic findings of conditions associated with hydronephrosis in the newborn. PMID:27156562

  9. Ultrasonography of hydronephrosis in the newborn: A practical review

    Energy Technology Data Exchange (ETDEWEB)

    Choi, Young Hun; Cheon, Jung Eun; Kim, Woo Sun; Kim, In One [Dept. of Radiology, Seoul National University College of Medicine, Seoul National University Children' s Hospital, Seoul (Korea, Republic of)

    2016-07-15

    Widespread use of fetal ultrasonography is accompanied by more frequent detection of antenatal hydronephrosis. Therefore, sonographic evaluation of neonates with a history of antenatal hydronephrosis is becoming more widespread. As an initial postnatal non-invasive imaging modality, ultrasonography is used to screen for persistence of hydronephrosis, determine the level and severity of obstruction, and contribute to appropriate diagnosis and treatment. This review aims to provide a practical overview of the sonographic evaluation of neonatal hydronephrosis and to describe the sonographic findings of conditions associated with hydronephrosis in the newborn.

  10. Microbunching and RF Compression

    International Nuclear Information System (INIS)

    Venturini, M.; Migliorati, M.; Ronsivalle, C.; Ferrario, M.; Vaccarezza, C.

    2010-01-01

    Velocity bunching (or RF compression) represents a promising technique complementary to magnetic compression to achieve the high peak current required in the linac drivers for FELs. Here we report on recent progress aimed at characterizing the RF compression from the point of view of the microbunching instability. We emphasize the development of a linear theory for the gain function of the instability and its validation against macroparticle simulations that represents a useful tool in the evaluation of the compression schemes for FEL sources.

  11. Mining compressing sequential problems

    NARCIS (Netherlands)

    Hoang, T.L.; Mörchen, F.; Fradkin, D.; Calders, T.G.K.

    2012-01-01

    Compression based pattern mining has been successfully applied to many data mining tasks. We propose an approach based on the minimum description length principle to extract sequential patterns that compress a database of sequences well. We show that mining compressing patterns is NP-Hard and

  12. Ultrasonography and computer tomography in the diagnosis of certain abdominal diseases

    International Nuclear Information System (INIS)

    Wawrzynek, Z.

    1981-01-01

    Ultrasonography and computer tomography in the diagnosis of digestive tract and spleen diseases as well as traumas are compared. It is concluded that ultrasonography is nearly as usefull as computer tomography. (author)

  13. Killian-Jamieson Diverticulum Mimicking a Thyroid Nodule on Ultrasonography: A Case Report

    International Nuclear Information System (INIS)

    Kim, Eun Soo; Lee, Kwan Seop; Yoon, Hoi Soo; Jeon, Eui Yong; Hwang, Hee Sung; Koh, Sung Hye; Kim, Min Jeong; Jang, Kyung Mi; Lee, Myung Jun; Lee, Yul

    2007-01-01

    Thyroid ultrasonography is widely used for diagnosis and cytologic evaluation of thyroid nodules. We encountered a case of Killian-Jamieson diverticulum, which was differentiated from a thyroid nodule using ultrasonography

  14. On the characterisation of the dynamic compressive behaviour of silicon carbides subjected to isentropic compression experiments

    Directory of Open Access Journals (Sweden)

    Zinszner Jean-Luc

    2015-01-01

    Full Text Available Ceramic materials are commonly used as protective materials particularly due to their very high hardness and compressive strength. However, the microstructure of a ceramic has a great influence on its compressive strength and on its ballistic efficiency. To study the influence of microstructural parameters on the dynamic compressive behaviour of silicon carbides, isentropic compression experiments have been performed on two silicon carbide grades using a high pulsed power generator called GEPI. Contrary to plate impact experiments, the use of the GEPI device and of the lagrangian analysis allows determining the whole loading path. The two SiC grades studied present different Hugoniot elastic limit (HEL due to their different microstructures. For these materials, the experimental technique allowed evaluating the evolution of the equivalent stress during the dynamic compression. It has been observed that these two grades present a work hardening more or less pronounced after the HEL. The densification of the material seems to have more influence on the HEL than the grain size.

  15. Compression for radiological images

    Science.gov (United States)

    Wilson, Dennis L.

    1992-07-01

    The viewing of radiological images has peculiarities that must be taken into account in the design of a compression technique. The images may be manipulated on a workstation to change the contrast, to change the center of the brightness levels that are viewed, and even to invert the images. Because of the possible consequences of losing information in a medical application, bit preserving compression is used for the images used for diagnosis. However, for archiving the images may be compressed to 10 of their original size. A compression technique based on the Discrete Cosine Transform (DCT) takes the viewing factors into account by compressing the changes in the local brightness levels. The compression technique is a variation of the CCITT JPEG compression that suppresses the blocking of the DCT except in areas of very high contrast.

  16. Atlas-based knee osteophyte assessment with ultrasonography and radiography

    DEFF Research Database (Denmark)

    Koski, J M; Kamel, Ayadi; Waris, P

    2016-01-01

    OBJECTIVES: To investigate intra- and inter-reader agreement of ultrasonography (US) and conventional radiography (CR) for the evaluation of osteophyte presence and size within the tibiofemoral joint. In addition, to correlate these findings with arthroscopic degeneration of the articular cartila...

  17. Ultrasonography and color Doppler in juvenile idiopathic arthritis

    DEFF Research Database (Denmark)

    Laurell, Louise; Court-Payen, Michel; Nielsen, Susan

    2012-01-01

    The wrist region is one of the most complex joints of the human body. It is prone to deformity and functional impairment in juvenile idiopathic arthritis (JIA), and is difficult to examine clinically. The aim of this study was to evaluate the role of ultrasonography (US) with Doppler in diagnosis...

  18. An unanticipated diagnosis with bedside ultrasonography in patients ...

    African Journals Online (AJOL)

    Although abdominal pain is a common presentation in emergency departments, rectus sheath hematoma (RSH) is among the rarest diagnosis. Here we present 2 cases of RSH likely caused by coughing due to upper respiratory tract infection. The two described cases were diagnosed by bedside ultrasonography and ...

  19. The accuracy rate of Alvarado score, ultrasonography, and ...

    African Journals Online (AJOL)

    Objective: In this study, we aim to compare the relationship between the Alvarado score, ultrasonography, and multislice computerized tomography (CT) findings used for the diagnosis of the patients who presented to our emergency unit with clinical features suggestive of acute appendicitis. Materials and Methods: ...

  20. Imaging in hematology. Part 1: Ultrasonography and conventional radiology

    International Nuclear Information System (INIS)

    Zhechev, Y.

    2003-01-01

    Applications of conventional ultrasonography techniques (B-mode or real time) in oncohematology are presented. The newer adaptations (in particular colour Doppler) provide incremental advantages that support their inclusion in the imaging techniques available to modern hematology. Conventional radiologic studies include chest and bone X-ray, gastrointestinal contrast examination and bipedal lymphangiography

  1. Impact of magnetic resonance urography and ultrasonography on ...

    African Journals Online (AJOL)

    Background: (1) To evaluate the diagnostic value of magnetic resonance urography (MRU) in comparison with ultrasonography (US) to determine the extent of upper urinary tract dilation and (2) to evaluate the impact of MRU on therapy management. Materials and Methods: From January 2005 to December 2010, ...

  2. In-utero diagnosis of Norrie disease by ultrasonography.

    Science.gov (United States)

    Redmond, R M; Vaughan, J I; Jay, M; Jay, B

    1993-03-01

    Obstetric ultrasonography of an obligate Norrie disease carrier revealed bilateral retinal detachments in a third trimester male fetus. Postnatal examination confirmed the diagnosis of Norrie disease. DNA linkage analysis with the markers L1.28 and MAO had been uninformative for this family. This report suggests that retinal detachment occurs late in the gestation of the affected fetus.

  3. Primary muscular hydatid: preoperative diagnosis Throught computerized tomography and ultrasonography

    International Nuclear Information System (INIS)

    Macho Fernandez, J.M.; Marin Cardenas, M.A.; Mazas Artasona, L.; Lample Lacasa, C.; Otero Sierra, C.; Hernandez Navarrete, M.J.; Gomez-Pereda, R.

    1995-01-01

    Primary muscular hydatid disease, is extremely rare,- but not exceptional-, comparatively with other atypical localization. In this article the authors revised 474 patients with hydatid disease over a ten years period. Three cases of primary muscular localization were found. The ultrasonography and computed tomography facilitates the preoperative diagnosis. (Author) 40 refs

  4. Evaluation of the hip joint by computed tomography and ultrasonography

    International Nuclear Information System (INIS)

    Anda, S.

    1991-04-01

    In patients with dysplastic hips the acetabular angles and femoral anteversion were determined in a CT investigation. Comparative investigations of femoral anteversion were made by ultrasonography and biomedical radiography. The investigations are described and the general conclusions discussed. 205 refs., 15 figs., 10 tabs

  5. Ultrasonography of the liver anatomy, procedure, normal and abnormal findings in diseased states

    International Nuclear Information System (INIS)

    Fukuda, Morimichi

    1996-01-01

    Although the very first attempt to use ultrasound for diagnostic purpose in medicine may be traced back to the 1940's, the modern ultrasound imaging has only been started in 1963 by G. Kossoff, who developed the idea of grayscale ultrasonography together with the automatic waterbath scanner, Octoson, to examine pelvic and other abdominal organs. The signal processing, logarithmic compression of incoming backscattered echo signals, greatly Improved image quality and thus facilitated the use of ultrasound imaging in clinical diagnostic purposes. The bistable, black and white ultrasound equipment were used in the 60's, and even sophisticated B-mode contact scanners had been completely replaced by the real-time B-mode equipment and then the technique started to be used widely in medical imaging in clinical and radiology departments. These rather drastic changes took place since the introduction of the phased array technique introduced by Somer in 1967 and later the linear array method introduced by Bom in 1970. Other rare metabolic diseases have to be analyzed carefully for the differential diagnosis. In summary, ultrasonography is a useful measure to identify the presence of pathologic changes in the liver. The information obtained is mostly of morphological nature, though some additional findings could be obtained by careful analysis of the sonographic features. Examination is quick, non-invasive and findings are fairly reproducible and even very small lesions could be identified. Combined use of the ultrasound imaging with other modalities such as the radio isotope scanning, X ray, CT or MRI will be very helpful in identifying and characterising the lesions in the liver

  6. Radiological Image Compression

    Science.gov (United States)

    Lo, Shih-Chung Benedict

    The movement toward digital images in radiology presents the problem of how to conveniently and economically store, retrieve, and transmit the volume of digital images. Basic research into image data compression is necessary in order to move from a film-based department to an efficient digital -based department. Digital data compression technology consists of two types of compression technique: error-free and irreversible. Error -free image compression is desired; however, present techniques can only achieve compression ratio of from 1.5:1 to 3:1, depending upon the image characteristics. Irreversible image compression can achieve a much higher compression ratio; however, the image reconstructed from the compressed data shows some difference from the original image. This dissertation studies both error-free and irreversible image compression techniques. In particular, some modified error-free techniques have been tested and the recommended strategies for various radiological images are discussed. A full-frame bit-allocation irreversible compression technique has been derived. A total of 76 images which include CT head and body, and radiographs digitized to 2048 x 2048, 1024 x 1024, and 512 x 512 have been used to test this algorithm. The normalized mean -square-error (NMSE) on the difference image, defined as the difference between the original and the reconstructed image from a given compression ratio, is used as a global measurement on the quality of the reconstructed image. The NMSE's of total of 380 reconstructed and 380 difference images are measured and the results tabulated. Three complex compression methods are also suggested to compress images with special characteristics. Finally, various parameters which would effect the quality of the reconstructed images are discussed. A proposed hardware compression module is given in the last chapter.

  7. Analysis of the Relationship Between the Epidural Spinal Cord Compression (ESCC) Scale and Paralysis Caused by Metastatic Spine Tumors.

    Science.gov (United States)

    Uei, Hiroshi; Tokuhashi, Yasuaki; Maseda, Masafumi

    2018-04-15

    A retrospective, single-institute, and radiographic study. To evaluate the relationship between the epidural spinal cord compression (ESCC) scale and the severity of metastatic spine tumor-induced paralysis. The ESCC scale is used to evaluate the grade of spinal cord compression on T2-weighted magnetic resonance imaging (MRI). However, few studies have investigated the relationship between such MRI findings and paralysis. The subjects were 467 patients with metastatic spine tumors and grade 1b or worse spinal cord compression according to the ESCC scale. Evaluations using this scale were performed by three spine surgeons, and results that were obtained by two or more surgeons were adopted. We also examined patients whose spinal cord compression deteriorated by one grade or more to American Spinal Injury Association (ASIA) grade C or worse within the first 3 weeks after MRI. The kappa coefficients for inter- and intraexaminer variability were 0.90 and 0.95, respectively. ASIA grade D or worse paralysis developed in at least 50% of the patients with ESCC grade 1b or worse spinal cord compression at the C1-T2 and at least 50% of those with ESCC grade 1c or worse spinal cord compression at the T3-L5. The frequency of ASIA grade C or worse paralysis was high among the patients with ESCC grade 2 or worse spinal cord compression at the C7-L1. Nineteen patients experienced rapid deterioration of one grade or more to ASIA grade C or worse paralysis within the first 3 weeks after MRI. Of these, paralysis occurred in at least 30% of the patients with anterolateral or circumferential cord compression combined with ESCC grade 2 or 3 compression at the C7-L1. The severity of paralysis was not correlated with the ESCC scale. Patients with anterolateral or circumferential ESCC grade 2 or 3 cord compression at the C7-L1 are at high risk of rapidly progressive paralysis. 4.

  8. Retrospective comparison of abdominal ultrasonography and radiography in the investigation of feline abdominal disease

    Science.gov (United States)

    Won, Wylen Wade; Sharma, Ajay; Wu, Wenbo

    2015-01-01

    Abdominal radiography and ultrasonography are commonly used as part of the initial diagnostic plan for cats with nonspecific signs of abdominal disease. This retrospective study compared the clinical usefulness of abdominal radiography and ultrasonography in 105 feline patients with signs of abdominal disease. The final diagnosis was determined more commonly with ultrasonography (59%) compared to radiography (25.7%). Ultrasonography was also able to provide additional clinically relevant information in 76% of cases, and changed or refined the diagnosis in 47% of cases. Based on these findings, ultrasonography may be sufficient as an initial diagnostic test for the investigation of feline abdominal disease. PMID:26483582

  9. Correlation Between Echodefecography and 3-Dimensional Vaginal Ultrasonography in the Detection of Perineal Descent in Women With Constipation Symptoms.

    Science.gov (United States)

    Murad-Regadas, Sthela M; Pinheiro Regadas, Francisco Sergio; Rodrigues, Lusmar V; da Silva Vilarinho, Adjra; Buchen, Guilherme; Borges, Livia Olinda; Veras, Lara B; da Cruz, Mariana Murad

    2016-12-01

    Defecography is an established method of evaluating dynamic anorectal dysfunction, but conventional defecography does not allow for visualization of anatomic structures. The purpose of this study was to describe the use of dynamic 3-dimensional endovaginal ultrasonography for evaluating perineal descent in comparison with echodefecography (3-dimensional anorectal ultrasonography) and to study the relationship between perineal descent and symptoms and anatomic/functional abnormalities of the pelvic floor. This was a prospective study. The study was conducted at a large university tertiary care hospital. Consecutive female patients were eligible if they had pelvic floor dysfunction, obstructed defecation symptoms, and a score >6 on the Cleveland Clinic Florida Constipation Scale. Each patient underwent both echodefecography and dynamic 3-dimensional endovaginal ultrasonography to evaluate posterior pelvic floor dysfunction. Normal perineal descent was defined on echodefecography as puborectalis muscle displacement ≤2.5 cm; excessive perineal descent was defined as displacement >2.5 cm. Of 61 women, 29 (48%) had normal perineal descent; 32 (52%) had excessive perineal descent. Endovaginal ultrasonography identified 27 of the 29 patients in the normal group as having anorectal junction displacement ≤1 cm (mean = 0.6 cm; range, 0.1-1.0 cm) and a mean anorectal junction position of 0.6 cm (range, 0-2.3 cm) above the symphysis pubis during the Valsalva maneuver and correctly identified 30 of the 32 patients in the excessive perineal descent group. The κ statistic showed almost perfect agreement (κ = 0.86) between the 2 methods for categorization into the normal and excessive perineal descent groups. Perineal descent was not related to fecal or urinary incontinence or anatomic and functional factors (sphincter defects, pubovisceral muscle defects, levator hiatus area, grade II or III rectocele, intussusception, or anismus). The study did not include a

  10. The inter-observer agreement in the assessment of carotid plaque neovascularization by contrast-enhanced ultrasonography: The impact of plaque thickness.

    Science.gov (United States)

    Chen, Jian; Zhang, Yan-Ming; Song, Ze-Zhou; Fu, Yan-Fei; Geng, Yu

    2018-04-10

    The interobserver agreement in the assessment of the grade of carotid plaque neovascularization by contrast-enhanced ultrasonography is poorly established. We examined 140 carotid plaques in 66 patients (all patients had bilateral plaques, and 8 patients had 2 plaques on one side). We performed conventional and contrast-enhanced ultrasonography to analyze the presence of carotid plaque neovascularization, which was graded by two independent observers whose interobserver agreement (κ) was evaluated according to the thickness of carotid plaque. For all carotid plaques, the mean κ was 0.689 (95% confidence interval 0.604-0.774). It was 0.689 (0.569-0.808), 0.637 (0.487-0.787), and 0.740 (0.585-0.896), respectively for carotid plaques with maximal thickness 3 mm. The interobserver agreement for assessing carotid plaque neovascularization by using contrast-enhanced ultrasonography is substantial and acceptable for research purposes, regardless of the maximal thickness of the plaque. © 2018 Wiley Periodicals, Inc.

  11. Compressed sensing & sparse filtering

    CERN Document Server

    Carmi, Avishy Y; Godsill, Simon J

    2013-01-01

    This book is aimed at presenting concepts, methods and algorithms ableto cope with undersampled and limited data. One such trend that recently gained popularity and to some extent revolutionised signal processing is compressed sensing. Compressed sensing builds upon the observation that many signals in nature are nearly sparse (or compressible, as they are normally referred to) in some domain, and consequently they can be reconstructed to within high accuracy from far fewer observations than traditionally held to be necessary. Apart from compressed sensing this book contains other related app

  12. Comparative analysis of pulsed doppler ultrasonography of portal vein vs indirect photography

    International Nuclear Information System (INIS)

    Chang, Jae Chun; Kwon, Huck Po; Hwang, Mi Soo; Kim, Sun Youn; Park, Bok Hwan; Lee, Hyun Ju; Kim, Hong Jin

    1990-01-01

    There are some limitation of interpretation in indirect photography via superior mesenteric artery. In order to supplement and predict indirect photography, we compared indirect photographic findings with pulsed doppler flowmetry in 38 hepatobiliary patients, and the results were as follow: 1. In case of normal main portal vein(MPV) filling, Pulsed Doppler always showed antegrade, continuous parabolic wave form and cases of abnormal MPV filling, showed unusual wave form and flow direction. 2. In normal filling case of proximal right portal vein, Pulsed Doppler almost showed normal continuous parabolic wave form but in normal filling cases of proximal left portal vein, occasionally showed undulating wave form. 3. In each side proximal portal vein abnormal filling case, we could observe abnormal doppler wave form and could obtain additional information using doppler wave form. 4. Mean portal flow velocity was significantly increased in higher photography grade(p=0.01) and congestion index was significantly decreased in higher photography grade(p=0.01). 5. We concluded that doppler ultrasonography could supplement incomplete indirect photography

  13. The value of intraoperative ultrasonography during the resection of relapsed irradiated malignant gliomas in the brain

    International Nuclear Information System (INIS)

    Mursch, Kay; Mursch, Julianne Behnke; Scholz, Martin; Brueck, Wolfgang

    2017-01-01

    The aim of this study was to investigate whether intraoperative ultrasonography (IOUS) helped the surgeon navigate towards the tumor as seen in preoperative magnetic resonance imaging and whether IOUS was able to distinguish between tumor margins and the surrounding tissue. Twenty-five patients suffering from high-grade gliomas who were previously treated by surgery and radiotherapy were included. Intraoperatively, two histopathologic samples were obtained a sample of unequivocal tumor tissue (according to anatomical landmarks and the surgeon's visual and tactile impressions) and a small tissue sample obtained using a navigated needle when the surgeon decided to stop the resection. This specimen was considered to be a boundary specimen, where no tumor tissue was apparent. The decision to take the second sample was not influenced by IOUS. The effect of IOUS was analyzed semi-quantitatively. All 25 samples of unequivocal tumor tissue were histopathologically classified as tumor tissue and were hyperechoic on IOUS. Of the boundary specimens, eight were hypoechoic. Only one harbored tumor tissue (P=0.150). Seventeen boundaries were moderately hyperechoic, and these samples contained all possible histological results (i.e., tumor, infiltration, or no tumor). During surgery performed on relapsed, irradiated, high-grade gliomas, IOUS provided a reliable method of navigating towards the core of the tumor. At borders, it did not reliably distinguish between remnants or tumor-free tissue, but hypoechoic areas seldom contained tumor tissue

  14. The value of intraoperative ultrasonography during the resection of relapsed irradiated malignant gliomas in the brain

    Energy Technology Data Exchange (ETDEWEB)

    Mursch, Kay; Mursch, Julianne Behnke [Dept. of Neurosurgery, Zentralklinik, Bad Berka (Germany); Scholz, Martin [Dept. of Neurosurgery, Klinikum Duisburg, Duisburg (Germany); Brueck, Wolfgang [Dept. of Neuropathology, Georg August Universitaet, Goettingen (Germany)

    2017-01-15

    The aim of this study was to investigate whether intraoperative ultrasonography (IOUS) helped the surgeon navigate towards the tumor as seen in preoperative magnetic resonance imaging and whether IOUS was able to distinguish between tumor margins and the surrounding tissue. Twenty-five patients suffering from high-grade gliomas who were previously treated by surgery and radiotherapy were included. Intraoperatively, two histopathologic samples were obtained a sample of unequivocal tumor tissue (according to anatomical landmarks and the surgeon's visual and tactile impressions) and a small tissue sample obtained using a navigated needle when the surgeon decided to stop the resection. This specimen was considered to be a boundary specimen, where no tumor tissue was apparent. The decision to take the second sample was not influenced by IOUS. The effect of IOUS was analyzed semi-quantitatively. All 25 samples of unequivocal tumor tissue were histopathologically classified as tumor tissue and were hyperechoic on IOUS. Of the boundary specimens, eight were hypoechoic. Only one harbored tumor tissue (P=0.150). Seventeen boundaries were moderately hyperechoic, and these samples contained all possible histological results (i.e., tumor, infiltration, or no tumor). During surgery performed on relapsed, irradiated, high-grade gliomas, IOUS provided a reliable method of navigating towards the core of the tumor. At borders, it did not reliably distinguish between remnants or tumor-free tissue, but hypoechoic areas seldom contained tumor tissue.

  15. The value of intraoperative ultrasonography during the resection of relapsed irradiated malignant gliomas in the brain

    Directory of Open Access Journals (Sweden)

    Kay Mursch

    2017-01-01

    Full Text Available Purpose The aim of this study was to investigate whether intraoperative ultrasonography (IOUS helped the surgeon navigate towards the tumor as seen in preoperative magnetic resonance imaging and whether IOUS was able to distinguish between tumor margins and the surrounding tissue. Methods Twenty-five patients suffering from high-grade gliomas who were previously treated by surgery and radiotherapy were included. Intraoperatively, two histopathologic samples were obtained a sample of unequivocal tumor tissue (according to anatomical landmarks and the surgeon’s visual and tactile impressions and a small tissue sample obtained using a navigated needle when the surgeon decided to stop the resection. This specimen was considered to be a boundary specimen, where no tumor tissue was apparent. The decision to take the second sample was not influenced by IOUS. The effect of IOUS was analyzed semi-quantitatively. Results All 25 samples of unequivocal tumor tissue were histopathologically classified as tumor tissue and were hyperechoic on IOUS. Of the boundary specimens, eight were hypoechoic. Only one harbored tumor tissue (P=0.150. Seventeen boundaries were moderately hyperechoic, and these samples contained all possible histological results (i.e., tumor, infiltration, or no tumor. Conclusion During surgery performed on relapsed, irradiated, high-grade gliomas, IOUS provided a reliable method of navigating towards the core of the tumor. At borders, it did not reliably distinguish between remnants or tumor-free tissue, but hypoechoic areas seldom contained tumor tissue.

  16. Ultrasonography and cholescintigraphy in the diagnostics of biliary tree

    International Nuclear Information System (INIS)

    Iskrenova, Zh.; Minchev, D.

    1997-01-01

    The purpose is to determine whether a reversed sequence of bile flow (i.e. small bowel followed by gallbladder) could serve as an indicator of chronic cholecystitis. 43 hepatobiliary scans were reviewed retrospectively with attention to the relative order of gallbladder and small bowel appearance during the first hour. Usually radioactive bile flows initially into the gallbladder followed by passage into the small bowel. The scintigraphic findings were correlated with results from gallbladder histopathology and gallbladder ultrasonography in 11 patients. The specificity of a reversed sequence for chronic cholecystitis was 82% using ultrasonography and 100% for histopathology. The visualization of gallbladder after the small bowel appears in patients referred for possible biliary tract disease predicts chronic cholecystitis (author)

  17. Role of ultrasonography in the ocular and the orbital diseases

    International Nuclear Information System (INIS)

    Kim, S. R.; Kim, K. S.; Lee, Y. C.; Park, S. S.

    1984-01-01

    With conventional methods including orbital arteriography, orbital venography, penumoobitography and positive contrast orbitography, imaging of eyeball and orbit is not only difficult, invasive or expensive but also nonspecific in result. Ultrasonography provides safe, specific and reliable way to obtain image of eyeball and orbit. Fifty six ultrasonograms of 50 patients which were referred under the impression of various ophthalmic diseases were analyzed. 1. Sixteen cases were normal. 2. Ocular diseases were 26 cases and extraocular orbital diseases were 8 cases. 3. Among the ocular diseases, 9 foreign body cases, 6 retinal detachment cases, 5 vitreous hemorrhage 4. Among the extraocular orbital diseases, 6 pseudotumor cases, 1 pseudolymphoma, 1 eyelid cyst case were diagnosed. 5. Ultrasonic findings were specific enough to differentiated from diseases and well corresponded with clinical and pathological diagnosis. 6. It can be concluded that ultrasonography is one of the most reliable imaging method in ocular and extraocular orbital diseases

  18. Potentialities of computed tomography and ultrasonography in colonic cancer

    International Nuclear Information System (INIS)

    Gorshkov, A.N.

    2001-01-01

    Data of examination of 59 patients with colonic cancer were used to consider the potentialities of transabdominal, transrectal ultrasonography and X-ay compound tomography and to assess their value in diagnosing colonic cancer, including its minor forms. Ultrasound and computed tomographic semiotics of colonic cancer and determines a place of the above techniques in the algorithm of radiation and instrumental studies are described. Inclusion of these techniques into the diagnostic algorithm may solve a range of differentially diagnostic problems and allows a preliminary analysis to be made in a tumor lesion according to the International TNM classification. Ultrasonography and X-ray computed tomography should be included into a range of basic methods for diagnosis of colonic cancer [ru

  19. Ultrasonography of Midline Scalp Masses : A Preliminary Report

    Energy Technology Data Exchange (ETDEWEB)

    Choi, Hyo Kyeong; Lee, Ho Kyu; Choi, Choong Gon; Kim, Kyeong Sook; Jung, Seung Mun; Suh, Dae Chul [Asan Medical Center University of Ulsan College of Medicine, Seoul (Korea, Republic of)

    1995-06-15

    We report our ultrasonographic experiences in the evaluation of small midline scalp masses. Ultrasonography was performed in four patients with midline scalp mass less than 3cm and its connecting tract into the cranialcavity. Ultrasonographic findings were correlated with pathologic results. There were three cephaloceles and one cystic lymph angioma. Two encephalomenin-goceles, located in occipital region, were mixed cystic and solid lesions and one atretic meningocele in parietal region was a solid lesion. Ultrasonogram of all three cases showed calvarial defect and connecting tract into the cranial cavity. On the contrary, a cystic lymph angioma in occipital region was a purely cystic mass without an associated calvarial defect. We suppose that ultrasonography could be a useful screening tool in the evaluation of midline scalp masses

  20. Transrectal ultrasonography of anorectal disease: advantages and disadvantages

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Min Ju [Dept. of Radiology, Korea University Anam Hospital, Korea University College of Medicine, Seoul (Korea, Republic of)

    2015-01-15

    Transrectal ultrasonography (TRUS) has been widely accepted as a popular imaging modality for Epub ahead of print evaluating the lower rectum, anal sphincters, and pelvic floor in patients with various anorectal diseases. It provides excellent visualization of the layers of the rectal wall and of the anatomy of the anal canal. TRUS is an accurate tool for the staging of primary rectal cancer, especially for early stages. Although magnetic resonance imaging is a modality complementary to TRUS with advantages for evaluating the mesorectum, external sphincter, and deep pelvic inflammation, three-dimensional ultrasonography improves the detection and characterization of perianal fistulas and therefore plays a crucial role in optimal treatment planning. The operator should be familiar with the anatomy of the rectum and pelvic structures relevant to the preoperative evaluation of rectal cancer and other anal canal diseases, and should have technical proficiency in the use of TRUS combined with an awareness of its limitations compared to magnetic resonance imaging.

  1. Henoch-Schonlein purpura: ultrasonography of scrotal and penile involvement

    Directory of Open Access Journals (Sweden)

    Youngsik Lim

    2015-04-01

    Full Text Available Testicular or scrotal involvement has been reported in children with Henoch-Schonlein purpura (HSP, but there are very few reports on penile involvement. We report the initial and follow-up ultrasonographic findings of scrotal and penile involvement of HSP in a 5-year-old boy. On ultrasonography, scrotal soft tissue thickening and epididymal swelling with increased vascularity were noted, and on the penis, a focal mass-like lesion appeared on the dorsal surface of the distal penis, having a hypoechoic mass-like appearance without visible vascular flow on a Doppler study. After 2 days of treatment, follow-up ultrasonography showed normal scrotum and penis with a resolved soft tissue mass-like lesion. Therefore, we think that HSP ultrasonographic findings involving the scrotum and penis might help to diagnose scrotal and penile involvement in a case of HSP and to avoid unnecessary medication and/or surgical procedures.

  2. Diagnostic ultrasonography in cattle with abdominal fat necrosis.

    Science.gov (United States)

    Tharwat, Mohamed; Buczinski, Sébastien

    2012-01-01

    This study describes the ultrasonographic findings in 14 cows with abdominal fat necrosis. Ultrasonography of the abdomen revealed the presence of heterogeneous hyperechoic masses and hyperechoic omentum with localized masses floating in a hypoechoic peritoneal fluid. A hyperechogenic rim was imaged around both kidneys. The intestines were coated with hyperechoic capsules and the intestinal lumens were constricted. Ultrasonographic examination of the pancreatic parenchyma showed an overall increased echogenicity which was homogenously distributed in 3 cases. A diagnosis of abdominal fat necrosis was made with ultrasound-guided biopsy of the echogenic masses, and thereafter at postmortem examination. Results from this study demonstrate the efficacy of ultrasonography as an imaging modality for antemortem diagnosis of abdominal lipomatosis in cattle. To the authors' knowledge, this study is the first that illustrates ultrasonographic findings in cattle affected with abdominal lipomatosis.

  3. Interobserver Variation of the Renal Length Measurement on Ultrasonography

    International Nuclear Information System (INIS)

    Jeong, Yoong Ki; Chung, Hye Weon; Kim, Tae Sung; Ryoo, Jae Wook; Kim, Tae Kyoung; Kim, Seung Hyup

    1995-01-01

    We assessed interobserver variation in the measurement of the renal length on ultrasonography. Ultrasonographic examinations were performed in randomly selected 50 patients. The maximallenhths of both kidneys were measured with calipers during the scanning from frozen images by three observers in a blinded fashion. There was a relatively constant tendency of an observer to measure a renal length either longer or shorter than the other observer(Kendall coefficient>0.05). Average interobserver variations were 0.51 cm (±0.42 cm) in right kidney and 0.53 cm (±0.41 cm) in left kidney and were within 1 cm in 91% right and 89% of left kidney. Interobserver variation about 1cm should be considered in the measurement of the renal length on ultrasonography

  4. On use of ultrasonography in obstetrics and gynecology

    International Nuclear Information System (INIS)

    Woo, Kwang Suk; Lee, Yong Woo

    1984-01-01

    Ultrasonography is playing an very important in diagnosis of normal pregnancy and the other diseases in the fields of obstetrics and gynecology. It is mainly used B-mode and Real time linear scan for pregnancy such as fetal movement during its early stage, fetal position, placenta location and biparietal diameter during its middle stage, and amniotic fluid and placenta previa during its late stage, as well as tumor accompanying pregnancy. Ultrasonography has been extensively used in the fields of obstetrics and gynecology for obtaining detailed images of soft tissues without hazard to the fetus and pregnant woman. In view of the need for its professionalism of high degree of skill, this treatise will introduce clinical instances and images obtained in the sonography room of the Seoul National University Hospital

  5. Reliable and Valid Assessment of Point-of-care Ultrasonography

    DEFF Research Database (Denmark)

    Todsen, Tobias; Tolsgaard, Martin Grønnebæk; Olsen, Beth Härstedt

    2015-01-01

    physicians' OSAUS scores with diagnostic accuracy. RESULTS: The generalizability coefficient was high (0.81) and a D-study demonstrated that 1 assessor and 5 cases would result in similar reliability. The construct validity of the OSAUS scale was supported by a significant difference in the mean scores......OBJECTIVE: To explore the reliability and validity of the Objective Structured Assessment of Ultrasound Skills (OSAUS) scale for point-of-care ultrasonography (POC US) performance. BACKGROUND: POC US is increasingly used by clinicians and is an essential part of the management of acute surgical...... conditions. However, the quality of performance is highly operator-dependent. Therefore, reliable and valid assessment of trainees' ultrasonography competence is needed to ensure patient safety. METHODS: Twenty-four physicians, representing novices, intermediates, and experts in POC US, scanned 4 different...

  6. The image of urachus adenocarcinoma on Doppler ultrasonography

    Energy Technology Data Exchange (ETDEWEB)

    Oyar, Orhan E-mail: o_oyar@hotmail.com; Yesildag, Ahmet; Gulsoy, Ufuk Kemal; Perk, Hakki

    2002-10-01

    Malignant urachal lesions are exceedingly rare and occur predominantly in adult life. In this case report, an adult patient with urachal carcinoma is presented with abdominal plain film, intravenous urography, gray-scale ultrasonography (US), Doppler US, and computed tomography (CT). Doppler US successfully showed the neovascularity with low resistive index value in the urachus tumor. We believe that Doppler US examination is helpful in the differential diagnosis of urachal carcinoma.

  7. Is ultrasonography essential before surgery in eyes with advanced cataracts?

    Directory of Open Access Journals (Sweden)

    Salman Amjad

    2006-01-01

    Full Text Available Background: Ultrasonography is an important tool for evaluating the posterior segment in eyes with opaque media. Aim: To study the incidence of posterior segment pathology in eyes with advanced cataract and to see whether certain features could be used as predictors for an abnormal posterior segment on ultrasound. Setting: Tertiary care hospital in South India. Methods and Materials: In this prospective study conducted over a 6-month period, all eyes with dense cataracts precluding visualization of fundus underwent assessment with ultrasound. Presence of certain patient and ocular "risk" factors believed to be associated with a higher incidence of abnormal posterior segment on ultrasound were looked for and the odds ratio (OR for posterior segment pathology in these eyes was calculated. Results: Of the 418 eyes assessed, 36 eyes (8.6% had evidence of posterior segment pathology on ultrasound. Retinal detachment (17 eyes; 4.1% was the most frequent abnormality detected. Among patient features, diabetes mellitus (OR= 4.9, P=0.003 and age below 50 years (OR= 15.4, P=0.001 were associated with a high incidence of abnormal ultrasound scans. In ocular features, posterior synechiae (OR= 20.2, P=0.000, iris coloboma (OR= 34.6, P=0.000, inaccurate projection of rays (OR= 15.1, P=0.002, elevated intraocular pressure (OR= 15.1, P=0.004, and keratic precipitates (OR= 22.4, P=0.004 were associated with high incidence of posterior segment pathology. Only four eyes (1.5% without these features had abnormal posterior segment on ultrasonography. Conclusions: Certain patient and ocular features are indicative of a high risk for posterior segment pathology and such patients should be evaluated by ultrasonography prior to cataract surgery. In the absence of these risk factors, the likelihood of detecting abnormalities on preoperative ultrasonography in eyes with advanced cataracts is miniscule.

  8. Comparison of ultrasonography and radiography in diagnosis of rib fractures

    OpenAIRE

    Pishbin, Elham; Ahmadi, Koorosh; Foogardi, Molood; Salehi, Maryam; Seilanian Toosi, Farrokh; Rahimi-Movaghar, Vafa

    2017-01-01

    Purpose: Rib fractures are the most common skeletal thoracic injuries resulting from blunt chest trauma. Half of the rib fractures are not detected upon a precise physical evaluation and radiographs. Recently ultrasonography (USG) has been investigated to detect rib fractures. But based on literature the usefulness of USG varies widely. This study was conducted to investigate the role of USG in the detection of possible rib fractures in comparison with radiography. Methods: In this cross-s...

  9. Pictorial essay: B-scan ultrasonography in ocular abnormalities

    International Nuclear Information System (INIS)

    Aironi, VD; Gandage, SG

    2009-01-01

    B-scan ultrasonography (USG) is a simple, noninvasive tool for diagnosing lesions of the posterior segment of the eyeball. Common conditions such as cataract, vitreous degeneration, retinal detachment, ocular trauma, choroidal melanoma, and retinoblastoma can be accurately evaluated with this modality. B-scan USG is cost-effective, which is an important consideration in the rural setting. In addition, it is noninvasive and easily available and the results are reproducible

  10. Ultrasonography of the omasum in 30 Saanen goats

    Directory of Open Access Journals (Sweden)

    Jacquat Désirée

    2011-02-01

    Full Text Available Abstract Background Primary diseases of the omasum are uncommon in goats, although the omasum may be involved in various gastrointestinal disorders. Examination of the caprine omasum via ultrasonography requires a good understanding of the normal appearance of the organ. However, in contrast to cattle, there is a lack of reference information on this topic in goats. Thus, the goal of the present study was to describe the results of ultrasonography of the omasum in 30 healthy Saanen goats. Results Ultrasonography was carried out in standing, non-sedated goats using a 5.0 MHz linear transducer. The location and size of the omasum, thickness of the omasal wall and visualisation of the abomasal laminae, contents and contractions were assessed. The omasum was visible from the 9th intercostal space (ICS in all the goats, and from the 8th and 10th ICSs in 29 and 24 goats, respectively. The omasum was seen medial to the liver, but only the omasal wall closest to the transducer was visible. The dorsal omasal limit formed a dorsally convex curve running from cranioventral to caudodorsal and was furthest from the dorsal midline in the 6th ICS. The ventral omasal limit formed a ventrally convex curve. The size of the omasum was largest (10.2 ± 3.1 cm in the 9th ICS and decreased cranially and caudally from this position. Active omasal motility was recorded in 20 goats with 0.3 to 2.0 contractions per minute. Conclusions The findings of this study provide reference ranges for the interpretation of the location and size of the omasum in goats with suspected omasal abnormalities. Ultrasonography is an ideal diagnostic tool for evaluation of the omasum, which is not accessible to conventional examination techniques, such as inspection, palpation, percussion and auscultation.

  11. Anisotropic Concrete Compressive Strength

    DEFF Research Database (Denmark)

    Gustenhoff Hansen, Søren; Jørgensen, Henrik Brøner; Hoang, Linh Cao

    2017-01-01

    When the load carrying capacity of existing concrete structures is (re-)assessed it is often based on compressive strength of cores drilled out from the structure. Existing studies show that the core compressive strength is anisotropic; i.e. it depends on whether the cores are drilled parallel...

  12. Experiments with automata compression

    NARCIS (Netherlands)

    Daciuk, J.; Yu, S; Daley, M; Eramian, M G

    2001-01-01

    Several compression methods of finite-state automata are presented and evaluated. Most compression methods used here are already described in the literature. However, their impact on the size of automata has not been described yet. We fill that gap, presenting results of experiments carried out on

  13. Quantitative Assessment of Synovial Vascularity Using Contrast-Enhanced Power Doppler Ultrasonography: Correlation with Histologic Findings and MR Imaging Findings in Arthritic Rabbit Knee Model

    International Nuclear Information System (INIS)

    Lee, Sang Hoon; Shin, Myung Jin; Kim, Seong Moon; Kim, Namkug; Suh, Sang Hyun; Suh, Jin Suck

    2008-01-01

    To validate contrast-enhanced power Doppler ultrasonography (PD US) for the evaluation of synovial vascularity in an arthritic rabbit knee model in correlation with MR and histological findings. Power Doppler ultrasonography was performed for carrageenin-induced arthritic left knee and control right knee of 13 rabbits, first without and then with sonic contrast agent enhancement (Levovist, Schering, Berlin Germany), followed by gadolinium-enhanced MR imaging. Synovial vascularity was quantitatively assessed by calculating the color pixel area in power Doppler sonography using a computer-aided image analysis program and by grading the enhancement on MR images: grade 1, enhancement of knee joint is less than one-third of the area; grade 2, one-third to two-thirds enhancement; and grade 3, more than two-thirds enhancement. Microvessel density (MVD) was measured on slides stained immunohistochemically for CD31 antigen for histological assessment. The mean area of color pixels in PD US changed from 4.37 to 16.42 mm 2 in the arthritic knee after enhancement (p 2 in the control knee (p 0.05). Sonic contrast-enhanced PD US improves the visualization of synovial vascularity and allows quantitative measurement in experimentally induced rabbit arthritic knees

  14. Ultrasonography of the equine shoulder: technique and normal appearance.

    Science.gov (United States)

    Tnibar, M A; Auer, J A; Bakkali, S

    1999-01-01

    This study was intended to document normal ultrasonographic appearance of the equine shoulder and anatomic landmarks useful in clinical imaging. Both forelimbs of five equine cadavers and both forelimbs of six live adult horses were used. To facilitate understanding of the images, a zoning system assigned to the biceps brachii and to the infraspinatus tendon was developed. Ultrasonography was performed with a real-time B-mode semiportable sector scanner using 7.5- and 5-MHz transducers. On one cadaver limb, magnetic resonance imaging (MRI) was performed using a system at 1.5 Tesla, T1-weighted spin-echo sequence. Ultrasonography images were compared to frozen specimens and MRI images to correlate the ultrasonographic findings to the gross anatomy of the shoulder. Ultrasonography allowed easy evaluation of the biceps brachii and the infraspinatus tendon and their bursae, the supraspinatus muscle and tendons, the superficial muscles of the shoulder, and the underlying humerus and scapula. Only the lateral and, partially, the caudal aspects of the humeral head could be visualized with ultrasound. Ultrasonographic appearance, orientation, and anatomic relationships of these structures are described. Ultrasonographic findings correlated well with MRI images and with gross anatomy in the cadavers' limbs.

  15. Evaluation of arterial embolization in treating hyperthyroidism by colour ultrasonography

    International Nuclear Information System (INIS)

    Sun Xiuying; Yang Jijin; Chen Ningning; Gu Limin; Wang Ying; Chen Jianquan

    2003-01-01

    Objective: To assess the effect of arterial embolization in treating hyperthyroidism by colour ultrasonography. Methods: Forty two cases of hyperthyroidism were treated with thyroid-arteries embolization. A few days before and 1, 3, 6 months after embolization, the echograms of thyroids were observed including the volumes of thyroids and the internal diameters of thyroid-arteries were measured with colour ultrasonography respectively. The Vs, Vd, Vm, PI, RI were measured with the Doppler and the quantities of blood flow were calculated. The relationships of changes for all these parameters and T 3 , T 4 and TSH were analysed. Results: Before artery embolization all thyroids were enlarged with diffusely homogenous or heterogenous low-echoes and nodules in some patients accompanied by widening of the thyroid arteries and their branches full of blood supply. The volume of thyroids decreased after artery embolization. 1-3 months later the echo of thyroids enhanced and got coarse with decrease of the thyroid vasculature and narrowing of vessel calibers except a few star- or stop-like blood streams were sometimes seen within the thyroids and no blood flow signals found in some cases. 3-6 months after embolization, the echo of thyroids decreased gradually or unevenly distributed. All the parameters of blood flow before and after the treatment showed statistically significant differences (P < 0.05). Conclusions: Embolization of thyroid arteries is a relatively new and effective technique in treating hyperthyroidism. Colour Doppler ultrasonography plays an important role for correct diagnosis and prognostication

  16. Peritoneal inclusion cysts: Changes on follow-up ultrasonography

    International Nuclear Information System (INIS)

    Kim, Jung Sik; Lee, Jin Hee; Lee, Hee Jung; Lee, Sung Moon; Woo, Seong Ku

    2003-01-01

    To evaluate the volume change of peritoneal inclusion cysts on the follow-up ultrasonography (US). From March 1995 to May 1999, thirty seven women with ultrasonographically diagnosed peritoneal inclusion cysts were included in this study. Six patients underwent surgery for several reasons. Follow-up ultrasonography was performed 70-456 days (mean=191 days) after initial US examination in 12 of the remaining 31 patient with no further treatment. US was performed with a 3.5 or 4 MHz transabdominal probe in all 18 patients who underwent either surgery or follow-up US, and additional tranvaginal US examination using a 5-7 MHz probe in 15 of 18 patients. The volume change of the cysts was recorded for each US examination. Three cysts (25%) (volume=170 cm 3 , 61 cm 3 , and 38 cm 3 , respectively) were completely resolved on the follow-up US while the other nine cysts showed a decreased volume in seven patients (58%) and increased volume in two patients (17%). Spontaneous regression of peritoneal inclusion cysts is more common than it is believed to be, and ultrasonography may be a useful follow-up examination for peritoneal inclusion cysts.

  17. Doppler Ultrasonography in Suspected Subclavian Artery Obstruction and in Patient Monitoring after Subclavian Stenting

    International Nuclear Information System (INIS)

    Kablak-Ziembicka, Anna; Przewlocki, Tadeusz; Pieniazek, Piotr; Musialek, Piotr; Kozanecki, Artur; Stopa, Ireneusz; Zalewski, Jaroslaw; Tracz, Wieslawa

    2007-01-01

    Purpose. Subclavian or innominate artery (SIA) stenosis affects up to 5% of patients referred to coronary bypass grafting; it is symptomatic in less than half of these. This study aimed to assess the Doppler ultrasonography (DU) findings in SIA obstruction and patients' follow-up after percutaneous angioplasty (PTA). Methods. The study enrolled 118 patients (68 men, 50 women), aged 61.3 ± 8.7 years, with suspected SIA obstruction, in whom peak systolic velocity (PSV) in the SIA and subclavian steal grade were assessed on DU and verified by quantitative angiography (QA). Serial follow-up DU was performed in patients treated with PTA. Results. Grade I-III of subclavian steal from the vertebral artery (VA) was found in 89.8% of patients. In the remaining 10.2% only a PSV increase in the SIA was observed. QA confirmed the presence of SIA obstruction in all patients (stenosis grade: 80.9 ± 17.3%). In patients with one-sided SIA obstruction, the ultrasonographic steal grade correlated with the QA stenosis grade (p < 0.001, r = 0.648). Lack of subclavian steal was noted in the case of distal subclavian stenosis, VA obstruction, VA originating from the aortic arch, and bilateral SIA obstruction. Successful PTA was performed in 77 of 83 patients referred to that procedure. PSV was reduced from 4.4 ± 1.2 (2.2-6.5) m/sec to 1.34 ± 0.51 (0.5-2.5) m/sec and flow in the VA was normalized. During the mean follow-up time of 24.7 ± 15.6 months, there was a gradual increase in the in-stent PSV as well as gradual VA flow alterations, resulting in symptom recurrence. More than a twofold PSV increase, compared with the post-PTA values, was an indicator of restenosis in 11 of 12 patients. Conclusions. Careful DU evaluation enables the recognition of SIA obstruction in all patients. Ninety percent of them have subclavian steal correlating with the stenosis grade. Restenosis can be reliably detected with DU based on in-stent PSV and VA flow alterations

  18. MRI versus ultrasonography to assess meniscal abnormalities in acute knees.

    Science.gov (United States)

    Cook, James L; Cook, Cristi R; Stannard, James P; Vaughn, Gavin; Wilson, Nichole; Roller, Brandon L; Stoker, Aaron M; Jayabalan, Prakash; Hdeib, Moses; Kuroki, Keiichi

    2014-08-01

    While magnetic resonance imaging (MRI) is often considered the "gold standard" diagnostic imaging modality for detection of meniscal abnormalities, it is associated with misdiagnosis in as high as 47% of cases, is costly, and is not readily available to a large number of patients. Ultrasonographic examination of the knee has been reported to be an effective diagnostic tool for this purpose with the potential to overcome many of the shortcomings of MRI. The purpose of this study is to determine the clinical usefulness of ultrasonography for diagnosis of meniscal pathology in patients with acute knee pain and compare its diagnostic accuracy to MRI in a clinical setting. With Institutional Review Board approval, patients (n = 71) with acute knee pain were prospectively enrolled with informed consent. Preoperative MRI (1.5 T) was performed on each affected knee using the hospital's standard equipment and protocols and read by faculty radiologists trained in musculoskeletal MRI. Ultrasonographic assessments of each affected knee were performed by one of two faculty members trained in musculoskeletal ultrasonography using a 10 to 14 MHz linear transducer. Arthroscopic evaluation of affected knees was performed by one of three faculty orthopedic surgeons to assess and record all joint pathology, which served as the reference standard for determining presence, type, and severity of meniscal pathology. All evaluators for each diagnostic modality were blinded to all other data. Data were collected and compared by a separate investigator to determine sensitivity (Sn), specificity (Sp), positive predictive value (PPV), negative predictive value (NPV), correct classification rate (CCR), likelihood ratios (LR[+] and LR[-]), and odds ratios. Preoperative ultrasonographic assessment of meniscal pathology was associated with Sn = 91.2%, Sp = 84.2%, PPV = 94.5%, NPV = 76.2%, CCR = 89.5%, LR(+) = 5.78, and LR(-) = 0.10. Preoperative MRI assessment of

  19. Comparative study of diagnostic efficiency of mammography and ultrasonography for breast cancer

    International Nuclear Information System (INIS)

    Koike, Yasuo; Terai, Naoki; Wakabayashi, Toru; Tsuchiya, Shin-ichi

    1995-01-01

    We performed a study of 448 women with breast cancer who visited the breast clinic of Nagano Cancer Center, and underwent mammography (MMG) and ultrasonography (US) at the last examination, between October 1983 and December 1993. These women subsequently underwent surgery at several hospitals after referral from our center. Definitive diagnoses of breast cancer were made histopathologically. Both MMG and US findings were graded using five-step criteria (indicating the level of malignancy) from I (normal) to V (definite malignancy). The diagnostic efficiencies of the two examinations were then compared clinicopathologically. Furthermore, on the basis of the results obtained, we considered supplemental diagnostic methods that could be introduced for mass screening of breast cancer. There was a significant difference between the incidence of cases diagnosed as V IV III b (malignancy) by US (71.9%) and those diagnosed by MMG (60.9%). Among cases suspected to be breast cancer by palpation, the proportion diagnosed as V IV III b (malignancy) by US (83.3%) was significantly higher than that diagnosed by MMG (73.7%). Among cases suspected to be mastopathy by palpation, the proportion diagnosed as malignant by US was higher than that diagnosed by MMG. The false negativity rate for palpation combined with MMG was higher than that for palpation with US. Among cases without palpable masses, the proportion diagnosed as malignant by MMG was higher than that diagnosed by US. However, for palpable tumors less than 5.0 cm in diameter, the proportion of cases diagnosed as malignant by US was higher than that diagnosed by MMG. In terms of the gross appearance of the cut surface, grade of cancer invasion, histological type and grade of chubbiness, the diagnostic efficiency of US was shown to be slightly better than that of MMG. The above results suggest that US should be considered as a supplemental method for introduction to mass screening of breast cancer. (author)

  20. Development and evaluation of a novel lossless image compression method (AIC: artificial intelligence compression method) using neural networks as artificial intelligence

    International Nuclear Information System (INIS)

    Fukatsu, Hiroshi; Naganawa, Shinji; Yumura, Shinnichiro

    2008-01-01

    This study was aimed to validate the performance of a novel image compression method using a neural network to achieve a lossless compression. The encoding consists of the following blocks: a prediction block; a residual data calculation block; a transformation and quantization block; an organization and modification block; and an entropy encoding block. The predicted image is divided into four macro-blocks using the original image for teaching; and then redivided into sixteen sub-blocks. The predicted image is compared to the original image to create the residual image. The spatial and frequency data of the residual image are compared and transformed. Chest radiography, computed tomography (CT), magnetic resonance imaging, positron emission tomography, radioisotope mammography, ultrasonography, and digital subtraction angiography images were compressed using the AIC lossless compression method; and the compression rates were calculated. The compression rates were around 15:1 for chest radiography and mammography, 12:1 for CT, and around 6:1 for other images. This method thus enables greater lossless compression than the conventional methods. This novel method should improve the efficiency of handling of the increasing volume of medical imaging data. (author)

  1. Analysis of a combined Rankine-vapour-compression refrigeration cycle

    International Nuclear Information System (INIS)

    Aphornratana, Satha; Sriveerakul, Thanarath

    2010-01-01

    This paper describes a theoretical analysis of a heat-powered refrigeration cycle, a combined Rankine-vapour-compression refrigeration cycle. This refrigeration cycle combines an Organic Rankine Cycle and a vapour-compression cycle. The cycle can be powered by low grade thermal energy as low as 60 deg. C and can produce cooling temperature as low as -10 deg. C. In the analysis, two combined Rankine-vapour-compression refrigeration cycles were investigated: the system with R22 and the system with R134a. Calculated COP values between 0.1 and 0.6 of both the systems were found.

  2. Effect of Kollidon VA®64 particle size and morphology as directly compressible excipient on tablet compression properties.

    Science.gov (United States)

    Chaudhary, R S; Patel, C; Sevak, V; Chan, M

    2018-01-01

    The study evaluates use of Kollidon VA ® 64 and a combination of Kollidon VA ® 64 with Kollidon VA ® 64 Fine as excipient in direct compression process of tablets. The combination of the two grades of material is evaluated for capping, lamination and excessive friability. Inter particulate void space is higher for such excipient due to the hollow structure of the Kollidon VA ® 64 particles. During tablet compression air remains trapped in the blend exhibiting poor compression with compromised physical properties of the tablets. Composition of Kollidon VA ® 64 and Kollidon VA ® 64 Fine is evaluated by design of experiment (DoE). A scanning electron microscopy (SEM) of two grades of Kollidon VA ® 64 exhibits morphological differences between coarse and fine grade. The tablet compression process is evaluated with a mix consisting of entirely Kollidon VA ® 64 and two mixes containing Kollidon VA ® 64 and Kollidon VA ® 64 Fine in ratio of 77:23 and 65:35. A statistical modeling on the results from the DoE trials resulted in the optimum composition for direct tablet compression as combination of Kollidon VA ® 64 and Kollidon VA ® 64 Fine in ratio of 77:23. This combination compressed with the predicted parameters based on the statistical modeling and applying main compression force between 5 and 15 kN, pre-compression force between 2 and 3 kN, feeder speed fixed at 25 rpm and compression range of 45-49 rpm produced tablets with hardness ranging between 19 and 21 kp, with no friability, capping, or lamination issue.

  3. Ultrasonography evaluation during the weaning process: the heart, the diaphragm, the pleura and the lung.

    Science.gov (United States)

    Mayo, P; Volpicelli, G; Lerolle, N; Schreiber, A; Doelken, P; Vieillard-Baron, A

    2016-07-01

    On a regular basis, the intensivist encounters the patient who is difficult to wean from mechanical ventilatory support. The causes for failure to wean from mechanical ventilatory support are often multifactorial and involve a complex interplay between cardiac and pulmonary dysfunction. A potential application of point of care ultrasonography relates to its utility in the process of weaning the patient from mechanical ventilatory support. This article reviews some applications of ultrasonography that may be relevant to the process of weaning from mechanical ventilatory support. The authors have divided these applications of ultrasonography into four separate categories: the assessment of cardiac, diaphragmatic, and lung function; and the identification of pleural effusion; which can all be evaluated with ultrasonography during a dynamic process in which the intensivist is uniquely positioned to use ultrasonography at the point of care. Ultrasonography may have useful application during the weaning process from mechanical ventilatory support.

  4. Acute Thoracolumbar Spinal Cord Injury: Relationship of Cord Compression to Neurological Outcome.

    Science.gov (United States)

    Skeers, Peta; Battistuzzo, Camila R; Clark, Jillian M; Bernard, Stephen; Freeman, Brian J C; Batchelor, Peter E

    2018-02-21

    Spinal cord injury in the cervical spine is commonly accompanied by cord compression and urgent surgical decompression may improve neurological recovery. However, the extent of spinal cord compression and its relationship to neurological recovery following traumatic thoracolumbar spinal cord injury is unclear. The purpose of this study was to quantify maximum cord compression following thoracolumbar spinal cord injury and to assess the relationship among cord compression, cord swelling, and eventual clinical outcome. The medical records of patients who were 15 to 70 years of age, were admitted with a traumatic thoracolumbar spinal cord injury (T1 to L1), and underwent a spinal surgical procedure were examined. Patients with penetrating injuries and multitrauma were excluded. Maximal osseous canal compromise and maximal spinal cord compression were measured on preoperative mid-sagittal computed tomography (CT) scans and T2-weighted magnetic resonance imaging (MRI) by observers blinded to patient outcome. The American Spinal Injury Association (ASIA) Impairment Scale (AIS) grades from acute hospital admission (≤24 hours of injury) and rehabilitation discharge were used to measure clinical outcome. Relationships among spinal cord compression, canal compromise, and initial and final AIS grades were assessed via univariate and multivariate analyses. Fifty-three patients with thoracolumbar spinal cord injury were included in this study. The overall mean maximal spinal cord compression (and standard deviation) was 40% ± 21%. There was a significant relationship between median spinal cord compression and final AIS grade, with grade-A patients (complete injury) exhibiting greater compression than grade-C and D patients (incomplete injury) (p compression as independently influencing the likelihood of complete spinal cord injury (p compression. Greater cord compression is associated with an increased likelihood of severe neurological deficits (complete injury) following

  5. The role of contrast-enhanced ultrasonography in image-guided liver ablations

    International Nuclear Information System (INIS)

    Pescatori, Lorenzo Carlo; Sconfienza, Luca Maria; Mauri, Giovanni

    2016-01-01

    We read with great interest the paper by Kim et al. entitled “Local ablation therapy with contrast enhanced ultrasonography for hepatocellular carcinoma: a practical review,” recently published in Ultrasonography. We think that contrast-enhanced ultrasonography (CEUS), together with the development of reliable navigation systems, is likely to represent one of the most important advances in image-guided ablations in recent years. Thus, we offer some considerations on the topic

  6. Prenatal diagnosis of Beckwith-Wiedemann syndrome by two- and three-dimensional ultrasonography

    Directory of Open Access Journals (Sweden)

    Edward Araujo Junior

    2013-12-01

    Full Text Available Beckwith-Wiedemann syndrome is a genetic syndrome characterized by macroglossia, omphalocele, fetal gigantism and neonatal hypoglycemia. The authors report a case of Beckwith-Wiedemann syndrome diagnosed in a 32-year-old primigravida in whom two-dimensional ultrasonography revealed the presence of abdominal wall cyst, macroglossia and polycystic kidneys. Three-dimensional ultrasonography in rendering mode was of great importance to confirm the previous two-dimensional ultrasonography findings.

  7. Evaluation of abdominal palpation, radiography and ultrasonography for pregenancy diagnosis in bitches

    International Nuclear Information System (INIS)

    Arunmozhi, N.; Naidu, K.V.; Sreenu, M.; Rao, A.S.

    2005-01-01

    Abdominal palpation, radiography and ultrasonography were compared for pregnancy diagnosis in bitches. The earliest correct diagnosis of pregnancy was made by 22 and 21 days with abdominal palpation and ultrasonography respectively, while radiography led to more accurate diagnosis in last trimester of pregnancy. All the methods revealed 100 per cent accuracy in last trimester where as ultrasonography gave constant results from day 21 up to termination of pregnancy followed by abdominal palpation

  8. Compressive laser ranging.

    Science.gov (United States)

    Babbitt, Wm Randall; Barber, Zeb W; Renner, Christoffer

    2011-12-15

    Compressive sampling has been previously proposed as a technique for sampling radar returns and determining sparse range profiles with a reduced number of measurements compared to conventional techniques. By employing modulation on both transmission and reception, compressive sensing in ranging is extended to the direct measurement of range profiles without intermediate measurement of the return waveform. This compressive ranging approach enables the use of pseudorandom binary transmit waveforms and return modulation, along with low-bandwidth optical detectors to yield high-resolution ranging information. A proof-of-concept experiment is presented. With currently available compact, off-the-shelf electronics and photonics, such as high data rate binary pattern generators and high-bandwidth digital optical modulators, compressive laser ranging can readily achieve subcentimeter resolution in a compact, lightweight package.

  9. Comparison of the results of abdominal ultrasonography and exploratory laparotomy in the dog and cat.

    Science.gov (United States)

    Pastore, Gina E; Lamb, Christopher R; Lipscomb, Victoria

    2007-01-01

    Results of preoperative ultrasonography and exploratory laparotomy were reviewed retrospectively in a series of 100 small animals to assess the agreement between ultrasonographic and surgical findings and to identify abdominal lesions likely to be missed by ultrasonography. Good agreement occurred between ultrasound reports and surgical reports in 64% of the animals, which supported the use of ultrasonography in potential surgical candidates. A major discrepancy was observed between the ultrasound report and surgical findings in 25% of the animals. Of the various types of pathology encountered in the study, gastrointestinal ulceration or perforation was the most likely lesion to be missed by ultrasonography.

  10. Doppler ultrasonography of the lower extremity arteries: anatomy and scanning guidelines

    Energy Technology Data Exchange (ETDEWEB)

    Hwang, Ji Young [Dept. of Radiology, Ewha Womans University School of Medicine, Seoul (Korea, Republic of)

    2017-04-15

    Doppler ultrasonography of the lower extremity arteries is a valuable technique, although it is less frequently indicated for peripheral arterial disease than for deep vein thrombosis or varicose veins. Ultrasonography can diagnose stenosis through the direct visualization of plaques and through the analysis of the Doppler waveforms in stenotic and poststenotic arteries. To perform Doppler ultrasonography of the lower extremity arteries, the operator should be familiar with the arterial anatomy of the lower extremities, basic scanning techniques, and the parameters used in color and pulsed-wave Doppler ultrasonography.

  11. Comparative study of scintigraphy, ultrasonography and computed tomography in the evaluation of liver tumours

    International Nuclear Information System (INIS)

    Tohyama, Junko; Ishigaki, Takeo; Ishikawa, Tsutomu

    1982-01-01

    A comparative study of scintigraphy, ultrasonography and computed tomography in 67 proven patients with clinically suspected liver tumours was reported. Scintigraphy was superior in sensitivity to ultrasonography and computed tomography. However, in specificity, scintigraphy was inferior to other two. Diagnostic efficacy of ultrasonography and computed tomography in detecting focal masses of the liver was not greatly different, and simultaneous interpretation of ultrasonogram and computed tomogram was more helpful than independent interpretation. So they were thought to be complementary. In conclusion, scintigraphy was thought to be the initial procedure in the diagnostic approach for focal liver masses and ultrasonography was second procedure because of no radiation hazards. And computed tomography should follow then. (author)

  12. Doppler ultrasonography of the lower extremity arteries: anatomy and scanning guidelines

    Directory of Open Access Journals (Sweden)

    Ji Young Hwang

    2017-04-01

    Full Text Available Doppler ultrasonography of the lower extremity arteries is a valuable technique, although it is less frequently indicated for peripheral arterial disease than for deep vein thrombosis or varicose veins. Ultrasonography can diagnose stenosis through the direct visualization of plaques and through the analysis of the Doppler waveforms in stenotic and poststenotic arteries. To perform Doppler ultrasonography of the lower extremity arteries, the operator should be familiar with the arterial anatomy of the lower extremities, basic scanning techniques, and the parameters used in color and pulsed-wave Doppler ultrasonography.

  13. Ultrasonography survey and thyroid cancer in the Fukushima Prefecture

    Energy Technology Data Exchange (ETDEWEB)

    Jacob, Peter; Kaiser, Jan Christian; Ulanovsky, Alexander [Helmholtz Zentrum Muenchen-German Research Center for Environmental Health, Department of Radiation Sciences, Institute of Radiation Protection, Neuherberg (Germany)

    2014-05-15

    Thyroid cancer is one of the major health concerns after the accident in the Fukushima Dai-ichi nuclear power station (NPS). Currently, ultrasonography surveys are being performed for persons residing in the Fukushima Prefecture at the time of the accident with an age of up to 18 years. Here, the expected thyroid cancer prevalence in the Fukushima Prefecture is assessed based on an ultrasonography survey of Ukrainians, who were exposed at an age of up to 18 years to {sup 131}I released during the Chernobyl NPS accident, and on differences in equipment and study protocol in the two surveys. Radiation risk of thyroid cancer incidence among survivors of the atomic bombings of Hiroshima and Nagasaki and preliminary estimates of thyroid dose due to the Fukushima accident were used for the prediction of baseline and radiation-related thyroid cancer risks. We estimate a prevalence of thyroid cancer of 0.027 % (95 % CI 0.010 %; 0.050 %) for the first screening campaign in the Fukushima Prefecture. Compared with the incidence rate in Japan in 2007, the ultrasonography survey is predicted to increase baseline thyroid cancer incidence by a factor of 7.4 (95 % CI 0.95; 17.3). Under the condition of continued screening, thyroid cancer during the first fifty years after the accident is predicted to be detected for about 2 % of the screened population. The prediction of radiation-related thyroid cancer in the most exposed fraction (a few ten thousand persons) of the screened population of the Fukushima Prefecture has a large uncertainty with the best estimates of the average risk of 0.1-0.3 %, depending on average dose. (orig.)

  14. [Technique of abdominal ultrasonography in newborn foals and normal findings].

    Science.gov (United States)

    Behn, C; Bostedt, H

    2000-09-01

    Under field conditions, the diagnosis of foal's diseases relies almost exclusively on the physical examination. As the signs of illness in the equine neonate are frequently vage and non-localizing, the diagnosis of diseases may be problematic. This often causes misinterpretations and leads to ineffective prophylaxis and treatment. The purpose of this study was to evaluate the usefulness of diagnostic ultrasonography of the foal's abdomen under field conditions to provide an optimized technique and to describe the normal findings. Diagnostic ultrasonography of the abdomen was performed after obtaining clinical history and passing the physical examination of 25 foals without signs of abdominal problems. The foals were scanned in a stable box, being restrained by three persons in semi-lateral recumbency. Usually, sedation was not necessary. The ventral abdominal wall was clipped, a generous amount of ultrasound coupling gel was applied and massaged on the skin surface. The ultrasonographic examination was carried out using a portable sector scanner ("Microimager 2000", Ausonics) with 5.0 and 7.5-MHz transducers or a combined 5.0 and 7.5-MHz transrectal linear-array scanner ("450 Enhanced", Pie Medical). Employing the 5.0-MHz sector scanner first, the abdomen was explored from caudal to cranial in left and right semi-lateral recumbency. The 7.5-MHz scanner was used to attain higher resolution of certain structures. The sector scanner turned out to be suitable under field conditions and adequate to examine the abdominal organs. The transrectal linear-array scanner also provided the most important informations, although it was difficult to maintain a good contact area of the scan head. By ultrasonography it was possible to identify the urinary bladder, kidneys, spleen, liver and part of the gastrointestinal tract. Thus, application of ultrasound could successfully be performed on newborn foals under field conditions.

  15. Stomach: ultrasonography evaluation and post mortem inspection in adult horses

    Directory of Open Access Journals (Sweden)

    Cristiano Chaves Pessoa da Veiga

    2014-06-01

    Full Text Available ABSTRACT. Veiga C.C.P., Cascon C.M., Souza B.G., Braga L.S.M., Souza V.C., Ferreira A.M.R. & Leite J.S. [Stomach: ultrasonography evaluation and post mortem inspection in adult horses.] Avaliação ultrassonográfica e anatomopatológica macroscópica do estômago de equinos destinados ao abate comercial. Revista Brasileira de Medicina Veterinária, 36(2:125-130, 2014. Instituto de Veterinária, Universidade Federal Rural do Rio de Janeiro, BR 465, km 7, Seropédica, 23890-000, RJ, Brasil. E-mail: radiovet@ufrrj.br The equine gastric ulcer syndrome (EGUS includes all symptomatic or asymptomatic cases of erosions, ulcers, gastritis, gastric emptying disorders, duodenitis, duodenal ulcers and complications of these disorders. Occupies a prominent place in the equine clinic where you can go for the death of the animal. Ultrasonography of the stomach is indicated when the animals showed clinical signs of gastric disease. The aim of this study was to describe the sonographic evaluation and macroscopic pathological findings of the stomach of adult horses intended for commercial slaughter. To this 39 intended for commercial slaughter horses were evaluated. Sonographic evaluation before slaughter transabdominal via the left side of abdomen for evaluation of the stomach was performed. After the slaughter of these animals their stomachs were collected, evaluated and photographed. The study concluded that ultrasonography identified the stomach in all animals evaluated, but did not allow a careful evaluation of the entire length of the viscera, especially the aglandular region and pleated border. All animals evaluated had injury to the gastric mucosa in different degrees. In animals evaluated, the stomach region was most affected by injuries glandular region, although the most severe lesions have been found in the ruffled border adjacent to aglandular region.

  16. High-resolution ultrasonography in assessing temporomandibular joint disc position.

    Science.gov (United States)

    Talmaceanu, Daniel; Lenghel, Lavinia Manuela; Bolog, Nicolae; Popa Stanila, Roxana; Buduru, Smaranda; Leucuta, Daniel Corneliu; Rotar, Horatiu; Baciut, Mihaela; Baciut, Grigore

    2018-02-04

    The purpose of this study was to determine the diagnostic value of high-resolution ultrasonography (US) in temporomandibular joint (TMJ) disc displacements. A number of 74 patients (148 TMJs) with signs and symptoms of TMJ disorders, according to the Research Diagnostic Criteria for Temporomandibular Disorders, were included in this study. All patients received US and magnetic resonance imaging (MRI) of both TMJs 1 to 5 days after the clinical examination. MRI examinations were performed using 1.5 T MRI equipment (Siemens Avanto, Siemens, Erlangen). Ultrasonographic examination was performed on a Hitachi EUB 8500 (Hitachi Medical Corp., Tokyo, Japan) scanner with L 54 M6.5-13 MHz linear transducer. MRI depicted 68 (45.95%) normal joints, 47 (31.76%) with disc displacement with reduction, 33 (22.3%) with disc displacement without reduction and 34 (22.97%) with degenerative changes. US detected 78 (52.7%) normal joints, 37 (25%) with disc displacement with reduction, 33 (22.3%) with disc displacement without reduction and 21 (14.19%) with degenerative changes. Compared to MRI, US showed a sensitivity of 93.1%, specificity of 87.88%, accuracy of 90.32%, a positive predictive value of 87.1% and a negative predictive value of 93.55% for overall diagnosis of disc displacement. The Youden index was 0.81. Based on our results, high-resolution ultrasonography showed high sensitivity, specificity and accuracy in the diagnosis of TMJ disc displacement. It could be a valuable imaging technique in assessing TMJ disc position. The diagnostic value of high-resolution ultrasonography depends strictly on the examiner's skills and on the equipment used.

  17. Contrast-enhanced Harmonic power Doppler ultrasonography: Improved depiction of vascularity and characterization of flow pattern in hepatocellular carcinoma

    International Nuclear Information System (INIS)

    Baek, Hyung Chul; Yoon, Kwon Ha; Kim, Chang Guhn; Park, Ki Han; Won, Jong Jin

    2000-01-01

    To evaluate the value of contrast-enhanced harmonic power Doppler ultrasonography (PDUS) in depiction and characterization of tumoral vascularity in hepatocellular carcinoma (HCC). Thirty-three patients with HCC were prospectively evaluated with harmonic PDUS before and after injection of the contrast agent SH U 508A (2.5g, 300 mg/ml ). Unenhanced and serial dynamic scans at 15, 30, 45, 60, 90, 120, 150, 180, 240, 300 seconds after injection of contrast agents were obtained using a tissue harmonic technique with power Doppler imaging. The tumoral vascularity was expressed as percentage of power Doppler area, which was measured quantitatively by a computerized program (Ultrasonic Imaging Tool; Soongsil University, Seoul, Korea). The grade (0, no signal; 1, less than 5%; 2, 5-25%; 3, more than 25%) and flow pattern (intratumoral, detour, basket, and mixed) of tumoral vascularity were analyzed. Peak time of contrast-enhancement was measured on each tumor. After injection of contrast agent, tumoral flow signals increased in all lesions (100%). At unenhanced harmonic PDUS, flow signals were detected in 17 HCCs (52%); 15 tumors (46%) demonstrated grade 1 vascularity; and two (6%), grade 2. At contrast-enhanced harmonic PDUS, all tumors were detected vascularity; five (15%) were grade 1; eight (24%), grade 2; and 20 (61%), grade 3. Flow patterns were demonstated as follows at unenhanced harmonic PDUS; intratumoral pattern in 13 tumors (76%), detour in 2 (12%), and basket in 2 (12%). After injection of contrast agent, intratumoral pattern in 7 tumors (21%), detour 0 (0%), basket in 3 (9%) and mixed in 23 (70%) were demonstrated. Peak time of enhancement after injection of contrast agent was 30- 90 seconds in majority of the patients. Contrast-enhanced harmonic PDUS would be valuable in depiction of vascularity and characterization of flow pattern in HCC.

  18. Contrast-enhanced Harmonic power Doppler ultrasonography: Improved depiction of vascularity and characterization of flow pattern in hepatocellular carcinoma

    Energy Technology Data Exchange (ETDEWEB)

    Baek, Hyung Chul; Yoon, Kwon Ha; Kim, Chang Guhn; Park, Ki Han; Won, Jong Jin [Wonkwang University School of Medicine, Iksa (Korea, Republic of)

    2000-12-15

    To evaluate the value of contrast-enhanced harmonic power Doppler ultrasonography (PDUS) in depiction and characterization of tumoral vascularity in hepatocellular carcinoma (HCC). Thirty-three patients with HCC were prospectively evaluated with harmonic PDUS before and after injection of the contrast agent SH U 508A (2.5g, 300 mg/ml ). Unenhanced and serial dynamic scans at 15, 30, 45, 60, 90, 120, 150, 180, 240, 300 seconds after injection of contrast agents were obtained using a tissue harmonic technique with power Doppler imaging. The tumoral vascularity was expressed as percentage of power Doppler area, which was measured quantitatively by a computerized program (Ultrasonic Imaging Tool; Soongsil University, Seoul, Korea). The grade (0, no signal; 1, less than 5%; 2, 5-25%; 3, more than 25%) and flow pattern (intratumoral, detour, basket, and mixed) of tumoral vascularity were analyzed. Peak time of contrast-enhancement was measured on each tumor. After injection of contrast agent, tumoral flow signals increased in all lesions (100%). At unenhanced harmonic PDUS, flow signals were detected in 17 HCCs (52%); 15 tumors (46%) demonstrated grade 1 vascularity; and two (6%), grade 2. At contrast-enhanced harmonic PDUS, all tumors were detected vascularity; five (15%) were grade 1; eight (24%), grade 2; and 20 (61%), grade 3. Flow patterns were demonstated as follows at unenhanced harmonic PDUS; intratumoral pattern in 13 tumors (76%), detour in 2 (12%), and basket in 2 (12%). After injection of contrast agent, intratumoral pattern in 7 tumors (21%), detour 0 (0%), basket in 3 (9%) and mixed in 23 (70%) were demonstrated. Peak time of enhancement after injection of contrast agent was 30- 90 seconds in majority of the patients. Contrast-enhanced harmonic PDUS would be valuable in depiction of vascularity and characterization of flow pattern in HCC.

  19. Diagnostic accuracy of the ultrasonography in complicated pregnancy

    International Nuclear Information System (INIS)

    Cha, Kyung Soo; Kim, Kun Sang; Park, Soo Soung

    1983-01-01

    Ultrasonography is an invaluable diagnostic method in Obstetrics. It provides safe, speedy and repeatable way to obtain image of normal and abnormal pregnancy. The ultrasonograms of 167 patients with suspicion of complicated pregnancy were analyzed. The results were as follows. 1. 86 patients showed normal ultrasonogram(50.9%). 100% in intrauterine fetal death and gross fetal anomaly, 100% in abnormal fetal position and number, 95% in pregnancy with pelvic mass, 83% in ectopic pregnancy, 81% in abortion, 78% in molar pregnancy, 74% in plancenta previa. 3. Ultrasonic diagnosis of abrupto placenta was difficult. 4. Diagnostic accuracy was 80% in bicornuate uterus and double vagina

  20. Clinical application of endoscopic ultrasonography for esophageal achalasia.

    Science.gov (United States)

    Minami, Hitomi; Inoue, Haruhiro; Isomoto, Hajime; Urabe, Shigetoshi; Nakao, Kazuhiko

    2015-04-01

    Endoscopic ultrasonography (EUS) has been widely used for evaluating the nature of diseases of various organs. The possibility of applying EUS for esophageal motility diseases has not been well discussed despite its versatility. At present, peroral endoscopic myotomy (POEM) for esophageal achalasia and related diseases has brought new attention to esophageal diseases because POEM provides a more direct approach to the inner structures of the esophageal wall. In the present study, we discuss the clinical utility of EUS in evaluating and treating esophageal motility diseases such as esophageal achalasia and related diseases. © 2015 The Authors. Digestive Endoscopy © 2015 Japan Gastroenterological Endoscopy Society.

  1. Comparison of the reliability of two hydronephrosis grading systems: The Society for Foetal Urology grading system vs. the Onen grading system

    International Nuclear Information System (INIS)

    Kim, S.-Y.; Kim, M.-J.; Yoon, C.S.; Lee, M.S.; Han, K.H.; Lee, M.-J.

    2013-01-01

    Aim: To compare the reliability of the conventional ultrasonography grading system for hydronephrosis as suggested by the Society for Fetal Urology (SFU) in 1993 and that developed by Onen in 2007. Materials and methods: One hundred and eighty kidneys in 90 paediatric patients were assessed by four radiologists using each of the two grading systems twice. The SFU system was graded 0–4 (0 = no hydronephrosis; 1 = visualized only renal pelvis; 2 = plus a few caliceal dilatation; 3 = all calyceal dilatation; 4 = plus parenchymal thinning). The Onen system was graded 0–4 (0 = no hydronephrosis; 1 = only renal pelvic dilatation; 2 = plus caliceal dilatation; 3 = plus 50% renal parenchymal loss). Cohen's kappa statistic was used to estimate intra- and interobserver agreement. The weighted least-squares approach was used to compare the intra-observer agreement, and bootstrapping was used to compare the interobserver agreement between the two systems. Results: Intra-observer agreement was substantial to almost perfect in both the SFU (κ 0.79–0.95) and the Onen (κ 0.66–0.97) grading system without difference. The overall interobserver agreement was substantial in both the SFU (κ 0.61–0.68) and the Onen (κ 0.66–0.76) grading system. However, interobserver agreement was fair to moderate for SFU grades 1 and 2 and Onen grades 2 and 3. Conclusion: Both the SFU and Onen grading system are reliable with good intra- and interobserver agreement. However, decreased interobserver agreement was demonstrated for SFU grades 1 and 2 and Onen grades 2 and 3

  2. Lens thickness assessment: anterior segment optical coherence tomography versus A-scan ultrasonography

    Directory of Open Access Journals (Sweden)

    Nikoo Hamzeh

    2015-12-01

    Full Text Available AIM: To assess lens thickness measurements with anterior segment-optical coherence tomography (AS-OCT in comparison with A-scan ultrasonography (A-scan US. METHODS: There were 218 adult subjects (218 eyes aged 59.2±9.2y enrolled in this prospective cross-sectional study. Forty-three eyes had open angles and 175 eyes had narrow angles. Routine ophthalmic exam was performed and nuclear opacity was graded using the Lens Opacities Classification System III (LOCS III. Lens thickness was measured by AS-OCT (Visante OCT, Carl Zeiss Meditec, Dublin, CA, USA. The highest quality image was selected for each eye and lens thickness was calculated using ImageJ software. Lens thickness was also measured by A-scan US. RESULTS: Interclass correlations showed a value of 99.7% for intra-visit measurements and 95.3% for inter-visit measurements. The mean lens thickness measured by AS-OCT was not significantly different from that of A-scan US (4.861±0.404 vs 4.866±0.351 mm, P=0.74. Lens thickness values obtained from the two instruments were highly correlated overall (Pearson correlation coefficient=0.81, P<0.001, and in all LOCS III specific subgroups except in grade 5 of nuclear opacity. Bland-Altman analysis revealed a 95% limit of agreement from -0.45 to 0.46 mm. Lens thickness difference between the two instruments became smaller as the lens thickness increased and AS-OCT yielded smaller values than A-scan US in thicker lens (β=-0.29, P<0.001 CONCLUSION: AS-OCT-derived lens thickness measurement is valid and comparable to the results obtained by A-scan US. It can be used as a reliable noncontact method for measuring lens thickness in adults with or without significant cataract.

  3. Quadriceps Function and Knee Joint Ultrasonography after ACL Reconstruction.

    Science.gov (United States)

    Pamukoff, Derek N; Montgomery, Melissa M; Moffit, Tyler J; Vakula, Michael N

    2018-02-01

    Individuals with anterior cruciate ligament reconstruction (ACLR) are at greater risk for knee osteoarthritis, partially because of chronic quadriceps dysfunction. Articular cartilage is commonly assessed using magnetic resonance imaging and radiography, but these methods are expensive and lack portability. Ultrasound imaging may provide a cost-effective and portable alternative for imaging the femoral cartilage. The purpose of this study was to compare ultrasonography of the femoral cartilage between the injured and uninjured limbs of individuals with unilateral ACLR, and to examine the association between quadriceps function and ultrasonographic measures of femoral cartilage. Bilateral femoral cartilage thickness and quadriceps function were assessed in 44 individuals with unilateral ACLR. Quadriceps function was assessed using peak isometric strength, and early (RTD100) and late (RTD200) rate of torque development. Cartilage thickness at the medial femoral condyle (P accounting for time since ACLR, quadriceps peak isometric strength was associated with cartilage thickness at the medial femoral condyle (r = 0.35, P = 0.02) and femoral cartilage cross-sectional area (r = 0.28, P = 0.04). RTD100 and RTD200 were not associated with femoral cartilage thickness or cross-sectional area. Individuals with ACLR have thinner cartilage in their injured limb compared with uninjured limb, and cartilage thickness is associated with quadriceps function. These results indicate that ultrasonography may be useful for monitoring cartilage health and osteoarthritis progression after ACLR.

  4. Three-dimensional ultrasonography in the diagnosis of deep endometriosis.

    Science.gov (United States)

    Guerriero, Stefano; Saba, Luca; Ajossa, Silvia; Peddes, Cristina; Angiolucci, Marco; Perniciano, Maura; Melis, Gian Benedetto; Alcázar, Juan Luis

    2014-06-01

    In the use of 'tenderness-guided' transvaginal ultrasound, is the diagnostic accuracy of three-dimensional (3D) ultrasonography better than two-dimensional (2D) ultrasonography in the identification of deep endometriosis? Three-dimensional ultrasonography has a significantly higher diagnostic accuracy in the diagnosis of posterior locations of deep endometriosis without intestinal involvement, such as the uterosacral ligaments, vaginal and rectovaginal endometriosis. The only previous study of the diagnosis of posterior compartment endometriosis reported an poor sensitivity of 3D ultrasonography for uterosacral and sigmoid colon involvement. This diagnostic test study included 202 patients scheduled for surgery because of clinical suspicion of deep pelvic endometriosis and was carried out between January 2009 and September 2012. Modified transvaginal ultrasonography was performed on all of the women by a single examiner. Two locations of deep endometriosis were considered: intestinal involvement and other posterior lesions (including vaginal location, rectovaginal septum and uterosacral ligaments). Once the 2D ultrasonography had been performed, the 3D acquisition was performed and the obtained volume was stored. To avoid the risk of recall bias, the same operator evaluated the 3D volumes 6 months after the last examination using virtual navigation to provide a presumptive diagnosis of the presence and localization of deep endometriosis. In addition, to evaluate the reproducibility of 3D, two operators with different levels of expertise performed a retrospective review of 3D volumes from a random sample of 35 patients, twice, 1 week apart to also assess intraobserver agreement. The diagnostic performance of both tests was expressed as area under the receiver-operating characteristics curve (AUC), sensitivity, specificity, positive and negative predictive values, positive (LR+) and negative (LR-) likelihood ratios, with their respective 95% confidence interval (CI

  5. Ultrasonography for neuraxial blocks: a review of the evidence.

    Science.gov (United States)

    Elgueta, Maria F; Duong, Silvia; Finlayson, Roderick J; Tran, De Q

    2017-05-01

    This narrative review summarizes the evidence derived from randomized controlled trials (RCTs) pertaining to the use of adjunctive ultrasonography (US) for neuraxial blocks. The literature search was conducted using the MEDLINE, EMBASE and PUBMED databases. For the MEDLINE and EMBASE searches, the MESH terms "ultrasonography" and key word "ultrasound" were queried; using the operator "and", they were combined with the MESH terms "neuraxial block," "epidural anesthesia," "epidural analgesia," "spinal anesthesia," "spinal analgesia," "intrathecal anesthesia," "intrathecal analgesia," "caudal anesthesia," and "caudal analgesia." For the PUBMED search, the search terms "ultrasound neuraxial," "ultrasound intrathecal," "ultrasound epidural" (limited to clinical trials), "ultrasound spinal" (limited to clinical trials), and "ultrasound caudal" (limited to clinical trials) were queried. Seventeen RCTs were retained for analysis. Compared to conventional palpation of landmarks, US assistance (i.e., preprocedural scanning) results in fewer needle passes/insertions and skin punctures for neuraxial blocks in obstetrical and surgical patients. These benefits seem most pronounced when expert operators carry out the sonographic exams and for patients displaying difficult spinal anatomy. Preliminary findings also suggest that US provides similar pain relief and functional improvement to fluoroscopy for epidural/caudal steroid injection in patients afflicted with chronic spinal pain. Although one trial demonstrated shorter needling time with US guidance (i.e., real-time scanning of needle advancement) compared to US assistance, these findings require further validation. Published reports of RCTs provide evidence to formulate limited recommendations regarding the use of adjunctive US for neuraxial blocks. Further well-designed RCTs are warranted.

  6. Intraoperative ultrasonography of liver, bile ducts and pancreas

    Directory of Open Access Journals (Sweden)

    Luciana Mendes de Oliveira Cerri

    Full Text Available The use of intraoperative ultrasonography (IOUS to evaluate liver, bile ducts and pancreatic disease, as compared to the results of preoperative ultrasonography and CT, is discussed. Forty-two patients who underwent abdominal surgery for suspected hepatobiliary and/or pancreatic disease were studied. The intraoperative study was carried out with a portable apparatus (Aloka 500, Japan, using 5.0 MHz and 7.5 MHz linear sterile transducers. The main indications for IOUS were the search for and/or evaluation of primary hepatic masses,hepatic abscesses or metastases, obstructive jaundice, or neuroendocrine tumors. In 15 cases (38.5 percent from the hepatobiliary group and in 7 cases (58.3 percent from the pancreatic group, a difference between preoperative and intraoperative findings was observed. The main difference was observed in relation to the number and size of hepatic and pancreatic lesions. The relationship between the lesions and the vascular structures was evaluated through IOUS. The method was also used to guide surgical procedures such as biopsies, the alcoholization of nodules, and the drainage of abscesses. IOUS plays an important role in detecting small hepatic and pancreatic nodules, in the assessment of anatomical relationships between the lesions and the vascular structures, and in the performance of interventionist procedures.

  7. Validation of equations for pleural effusion volume estimation by ultrasonography.

    Science.gov (United States)

    Hassan, Maged; Rizk, Rana; Essam, Hatem; Abouelnour, Ahmed

    2017-12-01

    To validate the accuracy of previously published equations that estimate pleural effusion volume using ultrasonography. Only equations using simple measurements were tested. Three measurements were taken at the posterior axillary line for each case with effusion: lateral height of effusion ( H ), distance between collapsed lung and chest wall ( C ) and distance between lung and diaphragm ( D ). Cases whose effusion was aspirated to dryness were included and drained volume was recorded. Intra-class correlation coefficient (ICC) was used to determine the predictive accuracy of five equations against the actual volume of aspirated effusion. 46 cases with effusion were included. The most accurate equation in predicting effusion volume was ( H  +  D ) × 70 (ICC 0.83). The simplest and yet accurate equation was H  × 100 (ICC 0.79). Pleural effusion height measured by ultrasonography gives a reasonable estimate of effusion volume. Incorporating distance between lung base and diaphragm into estimation improves accuracy from 79% with the first method to 83% with the latter.

  8. Effects of Elevated Temperature on Compressive Strength Of Concrete

    African Journals Online (AJOL)

    This study presents the results of investigation of the effects of elevated temperatures on the compressive strength of Grade 40 concrete. A total of thirty cube specimens were cast, cured in water at ambient temperature in the laboratory and subjected to various temperature regimes before testing. A concrete mix of 1:1:3 ...

  9. Damaging Effects of Dieldrex-20 on the Compressive Strength of ...

    African Journals Online (AJOL)

    Analysis of the results showed that as the percentage of aqueous solution of dilclrex-20 increases, the compressive strength of concrete decreases. This decrease is independent of concrete grade and age. It also showed that the 5 per cent aqueous solution of dieldrex-20 recommended dosage should be strictly adhered to ...

  10. Direct compression properties of microcrystalline cellulose and its ...

    African Journals Online (AJOL)

    The influence of silicified microcrystalline cellulose (SMCC) on the flow, compaction and tableting properties of metronidazole powder was investigated. The study compared medium grades of both SMCC and standard microcrystalline cellulose (MCC) as direct compressible excipients. The bulk densities, Hausner quotient ...

  11. Optical pulse compression

    International Nuclear Information System (INIS)

    Glass, A.J.

    1975-01-01

    The interest in using large lasers to achieve a very short and intense pulse for generating fusion plasma has provided a strong impetus to reexamine the possibilities of optical pulse compression at high energy. Pulse compression allows one to generate pulses of long duration (minimizing damage problems) and subsequently compress optical pulses to achieve the short pulse duration required for specific applications. The ideal device for carrying out this program has not been developed. Of the two approaches considered, the Gires--Tournois approach is limited by the fact that the bandwidth and compression are intimately related, so that the group delay dispersion times the square of the bandwidth is about unity for all simple Gires--Tournois interferometers. The Treacy grating pair does not suffer from this limitation, but is inefficient because diffraction generally occurs in several orders and is limited by the problem of optical damage to the grating surfaces themselves. Nonlinear and parametric processes were explored. Some pulse compression was achieved by these techniques; however, they are generally difficult to control and are not very efficient. (U.S.)

  12. Teachers' Grading Decision Making

    Science.gov (United States)

    Isnawati, Ida; Saukah, Ali

    2017-01-01

    This study investigated teachers' grading decision making, focusing on their beliefs underlying their grading decision making, their grading practices and assessment types, and factors they considered in grading decision making. Two teachers from two junior high schools applying different curriculum policies in grade reporting in Indonesian…

  13. Screening ultrasonography of 2,204 patients with blunt abdominal trauma in the Wenchuan earthquake.

    Science.gov (United States)

    Zhou, Jixiang; Huang, Jiwei; Wu, Hong; Jiang, Hui; Zhang, Heqing; Prasoon, Pankaj; Xu, Yinglong; Bai, Yannan; Qiu, Jianguo; Zeng, Yong

    2012-10-01

    Abdominal injuries constitute a small proportion of all earthquake-related traumas; however, it often resulted in fatal hemorrhage. Ultrasonography has been described as an effective triage tool in the evaluation of blunt abdominal trauma. We aimed to present an overview of the diagnostic accuracy of screening ultrasonography for patients with blunt abdominal trauma admitted to various hospitals during the Wenchuan earthquake in China. We retrospectively analyzed the patients with blunt abdominal trauma who underwent ultrasonography after admission to various hospitals. Ultrasonography findings were considered positive if evidence of free fluid or a parenchymal injury was identified. Ultrasonography findings were compared with the findings of computed tomography, diagnostic peritoneal lavage, repeated ultrasonography, cystography, operation, and/or the clinical course. Findings from 2,204 ultrasonographic examinations were evaluated. Findings of 199 ultrasonographic examinations (9.0%) were considered positive. Of the patients, 12 (0.5%) had a false-negative ultrasonographic findings; of this group, 3 (25%) required exploratory laparotomy. Ultrasonography had a sensitivity of 91.9%, specificity of 96.9%, and an accuracy of 96.6% for detection of abdominal injuries. Positive predictive value was 68.3%, and negative predictive value was 99.4%. Screening ultrasonography is highly reliable in the setting of blunt abdominal trauma after earthquake. It should be used as an initial diagnostic modality in the evaluation of most blunt abdominal trauma. Diagnostic study, level III.

  14. Ultrasonography and computed tomography in the study of orbital tumors and pseudo-tumoral lesions

    International Nuclear Information System (INIS)

    Marins, J.L.C.; Pereira, R.M.; Prando, A.; Selos Moreira, A.R. de

    1987-01-01

    The computerized tomography and the ultrasonography in the ocular and orbital patologies were considered as complementary each other. the ultrasonography method as choice for the detection of the eye lesions in the adult, particularly of vascular origin and in the follow-up of inflammatory and pseudo-tumoral lesions was chosen. (L.M.J.) [pt

  15. The detection of prostatic carcinoma. 4- or 7-MHz transrectal ultrasonography?

    NARCIS (Netherlands)

    Vleeming, R.; Noordzij, J. W.; de Reijke, T. M.; Kurth, K. H.

    1993-01-01

    In this prospective study a comparison of 4-versus 7-MHz transrectal ultrasonography for the detection of prostatic carcinoma is reported. A total of 150 prostates were biopsied due to suspicion of malignancy arising at either digital rectal examination, 4- and/or 7-MHz transrectal ultrasonography,

  16. [A Multimedia Tutorial to Train Ultrasonography of the Thyroid for Medical Students].

    Science.gov (United States)

    Ritter, Julia; Wolfram, Maximilian; Schuler, Stefan; Guntinas-Lichius, Orlando

    2017-11-01

    Physicians in education often have poor experience in practice and assessment of ultrasonography on entering their profession, due to a deficiency of training offers during their study of medicine. Hence, a multimedia device for stepwise learning and training ultrasonography of the thyroid was developed. A software for a portable ultrasonography system was used to design a multimedia device for ultrasonography of the thyroid. It allows the user to illustrate texts and pictorial material simultaneously with ultrasound examination in order to compare own findings with examples from a database. The device was evaluated by 8 medical students and compared to a tutor-guided training. A structured, stepwise manual for ultrasonography of the thyroid with a large content of examples in different sectional images was designed for simultaneous reconstruction with the ultrasonography device. The informative content of the device and the replicability of the examination procedure were evaluated positively. Assessment respecting clarity, eligibility for users without experience and learning success was varying. The tutorial to learn and train ultrasonography of the thyroid is an instrument for self-learning and improving practical education in ultrasonography in medical education. In the next version, the manual for the examination will be structured in greater detail. © Georg Thieme Verlag KG Stuttgart · New York.

  17. Student Attitudes Toward Grades and Grading Practices.

    Science.gov (United States)

    Stallings, William M.; Leslie, Elwood K.

    The result of a study designed to assess student attitudes toward grading practices are discussed. Questionnaire responses of 3439 students in three institutions were tabulated. Responses were generally negative toward conventional grading systems. (MS)

  18. Isentropic Compression of Argon

    International Nuclear Information System (INIS)

    Oona, H.; Solem, J.C.; Veeser, L.R.; Ekdahl, C.A.; Rodriquez, P.J.; Younger, S.M.; Lewis, W.; Turley, W.D.

    1997-01-01

    We are studying the transition of argon from an insulator to a conductor by compressing the frozen gas isentropically to pressures at which neighboring atomic orbitals overlap sufficiently to allow some electron motion between atoms. Argon and the other rare gases have closed electron shells and therefore remain montomic, even when they solidify. Their simple structure makes it likely that any measured change in conductivity is due to changes in the atomic structure, not in molecular configuration. As the crystal is compressed the band gap closes, allowing increased conductivity. We have begun research to determine the conductivity at high pressures, and it is our intention to determine the compression at which the crystal becomes a metal

  19. Pulsed Compression Reactor

    Energy Technology Data Exchange (ETDEWEB)

    Roestenberg, T. [University of Twente, Enschede (Netherlands)

    2012-06-07

    The advantages of the Pulsed Compression Reactor (PCR) over the internal combustion engine-type chemical reactors are briefly discussed. Over the last four years a project concerning the fundamentals of the PCR technology has been performed by the University of Twente, Enschede, Netherlands. In order to assess the feasibility of the application of the PCR principle for the conversion methane to syngas, several fundamental questions needed to be answered. Two important questions that relate to the applicability of the PCR for any process are: how large is the heat transfer rate from a rapidly compressed and expanded volume of gas, and how does this heat transfer rate compare to energy contained in the compressed gas? And: can stable operation with a completely free piston as it is intended with the PCR be achieved?.

  20. Medullary compression syndrome

    International Nuclear Information System (INIS)

    Barriga T, L.; Echegaray, A.; Zaharia, M.; Pinillos A, L.; Moscol, A.; Barriga T, O.; Heredia Z, A.

    1994-01-01

    The authors made a retrospective study in 105 patients treated in the Radiotherapy Department of the National Institute of Neoplasmic Diseases from 1973 to 1992. The objective of this evaluation was to determine the influence of radiotherapy in patients with medullary compression syndrome in aspects concerning pain palliation and improvement of functional impairment. Treatment sheets of patients with medullary compression were revised: 32 out of 39 of patients (82%) came to hospital by their own means and continued walking after treatment, 8 out of 66 patients (12%) who came in a wheelchair or were bedridden, could mobilize by their own after treatment, 41 patients (64%) had partial alleviation of pain after treatment. In those who came by their own means and did not change their characteristics, functional improvement was observed. It is concluded that radiotherapy offers palliative benefit in patients with medullary compression syndrome. (authors). 20 refs., 5 figs., 6 tabs

  1. A prospective comparison of transvaginal ultrasonography and diagnostic hysteroscopy in the evaluation of patients with abnormal uterine bleeding: clinical implications

    NARCIS (Netherlands)

    Emanuel, M. H.; Verdel, M. J.; Wamsteker, K.; Lammes, F. B.

    1995-01-01

    We determined the diagnostic value of transvaginal ultrasonography for endometrial and intrauterine abnormalities in patients with abnormal uterine bleeding. Between June 1, 1992, and June 1, 1993, 279 consecutive patients underwent transvaginal ultrasonography. Findings were compared with the final

  2. Muscle-tendon-related abnormalities detected by ultrasonography are common in symptomatic hip dysplasia

    DEFF Research Database (Denmark)

    Jacobsen, Julie Sandell; Bolvig, Lars; Hölmich, Per

    2018-01-01

    INTRODUCTION: Hip dysplasia is characterized by reduced acetabular coverage of the femoral head leading to an increased mechanical load on the hip joint and the acting hip muscles. Potentially, the muscles and tendons functioning close to the hip joint may present with overuse......-related ultrasonography findings. The primary aim was to report the prevalence of muscle-tendon-related abnormalities detected by ultrasonography in 100 patients with symptomatic hip dysplasia. The secondary aim was to investigate correlations between muscle-tendon-related abnormalities detected by ultrasonography......-tendon-related abnormalities detected by ultrasonography in the hip and groin region are common in patients with symptomatic hip dysplasia, and the ultrasonography findings of the iliopsoas and gluteus medius/minimus tendons are weakly to moderately correlated to pain related to muscles and tendons in these structures. Both...

  3. Differentiation of benign and malignant thyroid nodules based on the proportion of sponge-like areas on ultrasonography: imaging-pathologic correlation

    Directory of Open Access Journals (Sweden)

    Jee Young Kim

    2015-10-01

    Full Text Available Purpose: The purpose of this study was to determine whether it is possible to differentiate benign from malignant thyroid nodules according to the proportion of sponge-like appearance within the nodules. Methods: A total of 201 thyroid nodules containing sponge-like appearance from 195 patients (157 women and 38 men were included this study. Each thyroid nodule was classified into one of three grades by real-time ultrasonography (US based on the areas with a sponge-like appearance within nodule: grade I had sponge-like areas occupying 75%. We evaluated whether a correlation existed between these grades and cytopathologic diagnoses. Results: Of the 201 nodules, 196 were benign and five were malignant, and according to the US classification, 101 nodules were grade I, 45 were grade II, and 55 were grade III. Of the five malignant nodules, four were grade I, and one was grade II. No statistically significant difference was found in the rate of malignancy between grade III and grades I and II, due to insufficient statistical power. A sponge-like appearance was correlated with follicles filled with colloid and cholesterol granules in benign nodules and with papillary fronds around the dilated cystic spaces in malignant nodules. Conclusion: No malignancies were found in thyroid nodules with >75% sponge-like appearance. Due to the overall low incidence of malignancy and the limited number of patients, a statistically significant difference could not be found in the prevalence of malignancy depending on the proportion of sponge-like areas within the nodule.

  4. Association between varicocele grade and semen analysis parameter

    Directory of Open Access Journals (Sweden)

    Ira Ariyati

    2018-02-01

    Full Text Available Background: Varicocele is a condition characterized by elongation, dilatation and tortuousity of spermatic vein in pampiniform plexus. Approximately 50% of infertility cases among men are caused by varicocele. The varicocele may affect the components of sperm. This study aimed to determine the association between varicocele grade based on ultrasound Doppler examination and sperm concentration, sperm motility, and sperm morphology based on semen analysis examination.Methods: This was a descriptive, cross-sectional study which used secondary data from 85 patients that visited Department of Urology, Cipto Mangunkusumo Hospital, then underwent ultrasonography examination at Department of Radiology, Cipto Mangunkusumo Hospital and semen analysis examination at Department of Obstetrics and Gynecology, Cipto Mangunkusumo General Hospital.Results: Varicocele grade was significantly associated with sperm morphology, concentration and motility (all p<0.05. Significant association was found between maximum condition and semen analysis component.Conclusion: Varicocele grade may affect semen analysis component.

  5. Graph Compression by BFS

    Directory of Open Access Journals (Sweden)

    Alberto Apostolico

    2009-08-01

    Full Text Available The Web Graph is a large-scale graph that does not fit in main memory, so that lossless compression methods have been proposed for it. This paper introduces a compression scheme that combines efficient storage with fast retrieval for the information in a node. The scheme exploits the properties of the Web Graph without assuming an ordering of the URLs, so that it may be applied to more general graphs. Tests on some datasets of use achieve space savings of about 10% over existing methods.

  6. Venous compressions of the nerves in the lower limbs.

    Science.gov (United States)

    Artico, M; Stevanato, G; Ionta, B; Cesaroni, A; Bianchi, E; Morselli, C; Grippaudo, F R

    2012-06-01

    The lower limbs are frequently involved in neurovascular compression syndromes, owing to their anatomical, vascular and muscular characteristics and to the orthostatic position. These syndromes were identified by exclusion, using neuroimaging techniques and treated by microsurgical techniques. Eight patients with a neurovascular compression syndrome due to venous vascular lesions in the lower limbs (popliteal fossa, proximal and medial third of the inferior limb, tarsal tunnel) were selected. The symptomatology was characterized by pain, Tinel's sign, hyperalgesia, allodynia, numbness along the nerve course and foot weakness: all were exacerbated by the standing position, thus suggesting a neurovascular compression syndrome. Diagnostic tools comprised Doppler ultrasonography, Electromyography, CT 3D and MRI. Treatment consisted of microsurgery with neurovascular dissection. Following surgical treatment, rapid pain relief and a partial recovery of neurological deficits (including the ability to walk) was observed within 8-10 months. An early diagnosis of NCS using various neuroimaging techniques and prompt treatment may improve the response to surgical therapy. The aim of the case studies described is to improve understanding of these pathologies thus enabling correct clinical decisions.

  7. Ultrasonography and prostate-specific antigen (PSA) in differential diagnosis of prostate cancer and benign prostatic hyperplasia

    International Nuclear Information System (INIS)

    Mechev, D.S.; Shcherbyina, O.V.; Yatsik, V.Yi.; Gladka, L.Yu.

    2003-01-01

    The purpose of the work is analysis of diagnostic possibilities of transrectal ultrasonography and PSA in differential diagnosis of prostate cancer and benign prostatic hyperplasia. 142 patients have been investigated by transrectal ultrasonography. he transrectal ultrasonography and PSA are sensible tests in diagnosis of prostate cancer and in differential diagnosis of benign prostatic hyperplasia and prostate cancer

  8. Compressible generalized Newtonian fluids

    Czech Academy of Sciences Publication Activity Database

    Málek, Josef; Rajagopal, K.R.

    2010-01-01

    Roč. 61, č. 6 (2010), s. 1097-1110 ISSN 0044-2275 Institutional research plan: CEZ:AV0Z20760514 Keywords : power law fluid * uniform temperature * compressible fluid Subject RIV: BJ - Thermodynamics Impact factor: 1.290, year: 2010

  9. Temporal compressive sensing systems

    Science.gov (United States)

    Reed, Bryan W.

    2017-12-12

    Methods and systems for temporal compressive sensing are disclosed, where within each of one or more sensor array data acquisition periods, one or more sensor array measurement datasets comprising distinct linear combinations of time slice data are acquired, and where mathematical reconstruction allows for calculation of accurate representations of the individual time slice datasets.

  10. Compression of Infrared images

    DEFF Research Database (Denmark)

    Mantel, Claire; Forchhammer, Søren

    2017-01-01

    best for bits-per-pixel rates below 1.4 bpp, while HEVC obtains best performance in the range 1.4 to 6.5 bpp. The compression performance is also evaluated based on maximum errors. These results also show that HEVC can achieve a precision of 1°C with an average of 1.3 bpp....

  11. Gas compression infrared generator

    International Nuclear Information System (INIS)

    Hug, W.F.

    1980-01-01

    A molecular gas is compressed in a quasi-adiabatic manner to produce pulsed radiation during each compressor cycle when the pressure and temperature are sufficiently high, and part of the energy is recovered during the expansion phase, as defined in U.S. Pat. No. 3,751,666; characterized by use of a cylinder with a reciprocating piston as a compressor

  12. Ultrasonography-guided cobalt-60 brachytherapy for malignant glioma

    International Nuclear Information System (INIS)

    Sakai, Noboru; Takenaka, Katsunobu; Ueda, Tatsuya

    1989-01-01

    Brachytherapy with cobalt-60 source is reported. In this method it is characterized that the source is inserted interstitially with remote control system by after-loading method via outer catheter (using tandem tube), which was established in the center of residual tumor, using ultrasonography guide with trepanation, or intraoperatively put within the dead space after tumor resection. Six cases of deep-seated and recurrent malignant glioma, were treated with this method. A total dose of 20 to 45 Gy (10 to 15 Gy/day for 2 to 3 days) was delivered to the target. Additionally conventional external irradiation was followed. The effect of cobalt-60 brachytherapy on such tumors were favorable especially for well-circumscribed glioma less than 3 cm on CT scan. (author)

  13. Ultrasonography, CT, and ERCP in the diagnosis of choledochal stones

    International Nuclear Information System (INIS)

    Pasanen, P.; Partanen, K.; Pikkarainen, P.; Alhava, E.; Pirinen, A.; Janatuinen, E.

    1992-01-01

    A prospective study of jaundiced (n = 187) and nonjaundiced (n = 33) cholestatic patients was carried out to evaluate the sensitivity of ultrasonography (US), CT and endoscopic retrograde cholangiopancreatography (ERCP) in the detection of choledochal stone disease. Altogether 83 patients had the final diagnosis of choledocholithiasis. In the jaundiced patients, the sensitivity of US, CT, and ERCP was 22,5%, 23,2%, and 80,6%, respectively. In cases of cholestasis without jaundice, the values were 20%, 37,5%, and 66,7%. In patients in whom all 3 imaging studies were done (n = 64), the differences between US and ERCP and between CT and ERCP were statistically significant (p < 0.0001). In most false-negative ERCP studies (10/15), the clinical course of the disease strongly suggested a passed choledochal stone. On the basis of this study, we recommend prompt ERCP to be performed if choledochal stone disease is suspected on clinical grounds. (orig.)

  14. Medical auditing of whole-breast screening ultrasonography.

    Science.gov (United States)

    Kim, Min Jung

    2017-07-01

    Since breast ultrasonography (US) has been used as an adjunctive screening modality in women with dense breasts, the need has arisen to evaluate and monitor its possible harm and benefits in comparison with other screening modalities such as mammography. Recently, the fifth edition of the Breast Imaging Reporting and Data System published by the American College of Radiology has suggested auditing methods for screening breast US. However, the method proposed therein is slightly different from how diagnostic performance was calculated in previous studies on screening breast US. In this article, the background and core aspects of medical audits of breast cancer screening will be reviewed to provide an introduction to the medical auditing of screening breast US, with the goal of helping radiologists to understand and identify potential ways to improve outcomes.

  15. Contrast-Enhanced Ultrasonography in Crohn's Disease Diagnostics.

    Science.gov (United States)

    Białecki, Marcin; Białecka, Agnieszka; Laskowska, Katarzyna; Liebert, Ariel; Kłopocka, Maria; Serafin, Zbigniew

    2015-06-01

    The chronic nature of Crohn's disease (CD) implicates necessity of multiple control assessments throughout patient's life. It is accepted that in patients with CD requiring disease monitoring, magnetic resonance enterography (MRE) and computed tomography enterography (CTE) are--apart from endoscopy--imaging studies of first choice. In practice, diagnostic imaging of patients with CD is troublesome, since MRE is an expensive and complicated study, and CTE exposes patients to high doses of ionizing radiation. Therefore, there is a need for new, both non-invasive and effective, methods of imaging in CD. Contrast-Enhanced Ultrasonography (CEUS) is a relatively new method using gas-filled microbubbles serving as contrast agent. It allows for detailed assessment of blood perfusion within intestine wall and peri-intestinal tissues, which enables detection and monitoring of inflammation and its qualitative assessment. The purpose of this paper is to describe CEUS examination technique and its clinical applications in patients with Crohn's disease.

  16. The core content of clinical ultrasonography fellowship training.

    Science.gov (United States)

    Lewiss, Resa E; Tayal, Vivek S; Hoffmann, Beatrice; Kendall, John; Liteplo, Andrew S; Moak, James H; Panebianco, Nova; Noble, Vicki E

    2014-04-01

    The purpose of developing a core content for subspecialty training in clinical ultrasonography (US) is to standardize the education and qualifications required to provide oversight of US training, clinical use, and administration to improve patient care. This core content would be mastered by a fellow as a separate and unique postgraduate training, beyond that obtained during an emergency medicine (EM) residency or during medical school. The core content defines the training parameters, resources, and knowledge of clinical US necessary to direct clinical US divisions within medical specialties. Additionally, it is intended to inform fellowship directors and candidates for certification of the full range of content that might appear in future examinations. This article describes the development of the core content and presents the core content in its entirety. © 2014 by the Society for Academic Emergency Medicine.

  17. Medical auditing of whole-breast screening ultrasonography

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Min Jung [Dept. of Radiology, Research Institute of Radiological Science, Severance Hospital, Yonsei University College of Medicine, Seoul (Korea, Republic of)

    2017-07-15

    Since breast ultrasonography (US) has been used as an adjunctive screening modality in women with dense breasts, the need has arisen to evaluate and monitor its possible harm and benefits in comparison with other screening modalities such as mammography. Recently, the fifth edition of the Breast Imaging Reporting and Data System published by the American College of Radiology has suggested auditing methods for screening breast US. However, the method proposed therein is slightly different from how diagnostic performance was calculated in previous studies on screening breast US. In this article, the background and core aspects of medical audits of breast cancer screening will be reviewed to provide an introduction to the medical auditing of screening breast US, with the goal of helping radiologists to understand and identify potential ways to improve outcomes.

  18. Endoscopic ultrasonography and rectal duplication cyst in an adult.

    Science.gov (United States)

    Castro-Poças, Fernando M; Araújo, Tarcísio P; Silva, Jorge D; Gonçalves, Vicente S

    2017-01-01

    Rectal duplication cysts account for 4% of all duplications of the alimentary tract. Presentation in adulthood is rare. An asymptomatic 54-year-old man was referred for endoscopic colorectal cancer screening. A bulging mass covered by normal mucosa was identified in the rectum. Endoscopic ultrasonography (EUS) with fine needle aspiration (FNA) was made for a diagnosis of rectal duplication cyst. The patient was operated and the diagnosis was confirmed. The diagnosis of the rectal duplication cyst is a challenge. EUS may have a singular role when identifying a muscular layer, because this is the only absolutely necessary criterion for the diagnosis. FNA by EUS may eventually identify colorectal and/or heterotypic epithelium that are the other diagnostic criteria of the duplication cyst.

  19. Cholangiocarcinoma in Magnetic Resonance Cholangiopancreatography and Fascioliasis in Endoscopic Ultrasonography

    Directory of Open Access Journals (Sweden)

    Amir Houshang Mohammad Alizadeh

    2011-10-01

    Full Text Available Fascioliasis is a worldwide zoonotic infection with Fasciola hepatica and Fasciola gigantica. The zoonoses are particularly endemic in sheep-raising countries and are also endemic in Iran. Typical symptoms that may be associated with fascioliasis can be divided by phases of the disease, including the acute or liver phase, the chronic or biliary phase, and ectopic or pharyngeal fascioliasis. Cholestatic symptoms may be absent, and in some cases diagnosis and treatment may be preceded by a long period of abdominal pain, eosinophilia and vague gastrointestinal symptoms. We report a case with epigastric and upper quadrant abdominal pain for the last 4 years, with imaging suggesting cholangiocarcinoma. Considering a new concept of endoscopic ultrasonography, at last F. hepatica was extracted with endoscopic retrograde cholangiography.

  20. Clinical impact of endoscopic ultrasonography at a county hospital

    DEFF Research Database (Denmark)

    Ainsworth, A P; Mortensen, M B; Durup, J

    2002-01-01

    BACKGROUND AND STUDY AIMS: Although endoscopic ultrasonography (EUS) is a well-described examination method, there have been few reports concerning its clinical impact. The aim of this study was to describe EUS as it is performed at a county hospital, with an emphasis on the indications...... and clinical outcome. PATIENTS AND METHODS: Patients examined using EUS between December 1997 and November 2000 were recorded prospectively. Follow-up was conducted by examining each patient's medical records at least 3 months after the investigation. The EUS findings were compared with the patient's final...... management strategy in 80 patients (24 %). CONCLUSIONS: EUS has a high level of accuracy and a substantial clinical impact when performed in an unselected population. The estimated numbers of investigations needed appear to justify setting up an EUS center at institutions with a catchment population of 350...

  1. Ultrasonography of small intestinal obstructions: a contemporary approach.

    Science.gov (United States)

    Garcia, D A A; Froes, T R; Vilani, R G D O C; Guérios, S D; Obladen, A

    2011-09-01

    To assess the accuracy of intestinal ultrasound for diagnosis of intestinal obstruction in dogs and cats. A prospective clinical study was performed. Inclusion criteria were dogs and cats with clinical signs suggestive of gastrointestinal obstruction. Animals with no obstruction detected on ultrasound were excluded if they could not be monitored for 48 hours to confirm absence of obstruction. Sonographic diagnosis of small intestinal obstruction was based on identification of at least two findings suggestive of intestinal obstruction. Ninety-two patients suspected of having intestinal obstruction were included. Correct diagnosis of intestinal obstruction was made in 21 cases (23%), and in 68 (74%) this diagnosis was excluded. Interpretation of the images on prospective analysis had sensitivity, positive predictive, specificity and negative predictive values of 100%, 87.5%, 95.8% and 100%, respectively. Ultrasonography is an excellent method for investigation of animals with gastrointestinal disorders, and is particularly useful for excluding obstructive processes. © 2011 British Small Animal Veterinary Association.

  2. Bedside Ultrasonography: A Useful Tool For Traumatic Pneumothorax

    International Nuclear Information System (INIS)

    Mumtaz, U.; Zahur, Z.; Chaudhry, M. A.; Warraich, R. A.

    2016-01-01

    Objective: To compare the diagnostic accuracy of bedside ultrasound and supine chest radiography for the diagnosis of traumatic pneumothorax. Study Design: Analytical study. Place and Duration of Study: PIMS and PAEC General Hospital, Islamabad, from November 2014 to August 2015. Methodology: Patients coming to emergency departments of the study centres, who had sustained chest injuries, were inducted. Their portable bedside ultrasound and supine chest radiographs were taken for assessing pneumothorax and subsequently CT chest was done for confirmation as gold standard. Result: Based on CT findings, sensitivity for ultrasonography and chest radiography was found to be 83.33 percentage and 54.76 percentage, respectively and specificity of 100 percentage for both modalities. Conclusion: Ultrasound can be used as a useful and suitable adjunct to CT in trauma patients as it is easily available, non-invasive, bedside, easily examined with no radiation risk. (author)

  3. An audit of ultrasonography performed and reported by trainee radiologists.

    Science.gov (United States)

    Eze, K C; Marchie, T T; Eze, C U

    2009-01-01

    Proforma information, instructions and procedures of training in radiology are lacking in Nigeria. To describe the errors in ultrasonography performed by unsupervised trainee radiologists. The radiology records of all ultrasound scans (USS) carried out and all reports that came back to the unit of the authors on account of misdiagnosis, doubtful diagnosis, misinformation or error in the reports were studied. The patients with the returned reports were rescanned where available by consultants and the collected data analysed. A total of 4680 patients had ultrasound studies without supervision resulting in 605 (12.93%) queried reports. The USS scans of 235 (5.02%) patients were repeated with consultants in attendance resulting in significant change in reports of 95 (2.03%) patients. Analysis of the request cards of 605 queried reports showed omission of relevant clinical information 463 (76.53%), outright wrong information 65 (10.73%),and unconventional abbreviations 139 (22.98%), while 493 (81.49%) were completed by a nurse, medical student or junior resident. Typographical errors comprised 174 (28.76%) of the 605 queried reports. False negative error was the highest type of error seen in 55 (57.89%) of the 95 patients with significant change in their report after repeat scan as lesions not detected were not documented. Trainee radiologists make significant errors in carrying out and reporting ultrasonography without adequate direct supervision of the study by their training consultants. Majority of the errors originate from lack of accurate filling of the patients request cards by the requesting physicians, lack of adequate preparation for the intended study, and typographical errors in writing reports. False negative reports are by far the greatest cause of errors recorded as lesions not detected were not documented.

  4. Adaptive sound speed correction for abdominal ultrasonography: preliminary results

    Science.gov (United States)

    Jin, Sungmin; Kang, Jeeun; Song, Tai-Kyung; Yoo, Yangmo

    2013-03-01

    Ultrasonography has been conducting a critical role in assessing abdominal disorders due to its noninvasive, real-time, low cost, and deep penetrating capabilities. However, for imaging obese patients with a thick fat layer, it is challenging to achieve appropriate image quality with a conventional beamforming (CON) method due to phase aberration caused by the difference between sound speeds (e.g., 1580 and 1450m/s for liver and fat, respectively). For this, various sound speed correction (SSC) methods that estimate the accumulated sound speed for a region-of interest (ROI) have been previously proposed. However, with the SSC methods, the improvement in image quality was limited only for a specific depth of ROI. In this paper, we present the adaptive sound speed correction (ASSC) method, which can enhance the image quality for whole depths by using estimated sound speeds from two different depths in the lower layer. Since these accumulated sound speeds contain the respective contributions of layers, an optimal sound speed for each depth can be estimated by solving contribution equations. To evaluate the proposed method, the phantom study was conducted with pre-beamformed radio-frequency (RF) data acquired with a SonixTouch research package (Ultrasonix Corp., Canada) with linear and convex probes from the gel pad-stacked tissue mimicking phantom (Parker Lab. Inc., USA and Model539, ATS, USA) whose sound speeds are 1610 and 1450m/s, respectively. From the study, compared to the CON and SSC methods, the ASSC method showed the improved spatial resolution and information entropy contrast (IEC) for convex and linear array transducers, respectively. These results indicate that the ASSC method can be applied for enhancing image quality when imaging obese patients in abdominal ultrasonography.

  5. Contrast-enhanced endoscopic ultrasonography in digestive diseases.

    Science.gov (United States)

    Hirooka, Yoshiki; Itoh, Akihiro; Kawashima, Hiroki; Ohno, Eizaburo; Itoh, Yuya; Nakamura, Yosuke; Hiramatsu, Takeshi; Sugimoto, Hiroyuki; Sumi, Hajime; Hayashi, Daijiro; Ohmiya, Naoki; Miyahara, Ryoji; Nakamura, Masanao; Funasaka, Kohei; Ishigami, Masatoshi; Katano, Yoshiaki; Goto, Hidemi

    2012-10-01

    Contrast-enhanced endoscopic ultrasonography (CE-EUS) was introduced in the early 1990s. The concept of the injection of carbon dioxide microbubbles into the hepatic artery as a contrast material (enhanced ultrasonography) led to "endoscopic ultrasonographic angiography". After the arrival of the first-generation contrast agent, high-frequency (12 MHz) EUS brought about the enhancement of EUS images in the diagnosis of pancreatico-biliary diseases, upper gastrointestinal (GI) cancer, and submucosal tumors. The electronic scanning endosonoscope with both radial and linear probes enabled the use of high-end ultrasound machines and depicted the enhancement of both color/power Doppler flow-based imaging and harmonic-based imaging using second-generation contrast agents. Many reports have described the usefulness of the differential diagnosis of pancreatic diseases and other abdominal lesions. Quantitative evaluation of CE-EUS images was an objective method of diagnosis using the time-intensity curve (TIC), but it was limited to the region of interest. Recently developed Inflow Time Mapping™ can be generated from stored clips and used to display the pattern of signal enhancement with time after injection, offering temporal difference of contrast agents and improved tumor characterization. On the other hand, three-dimensional CE-EUS images added new information to the literature, but lacked positional information. Three-dimensional CE-EUS with accurate positional information is awaited. To date, most reports have been related to pancreatic lesions or lymph nodes. Hemodynamic analysis might be of use for diseases in other organs: upper GI cancer diagnosis, submucosal tumors, and biliary disorders, and it might also provide functional information. Studies of CE-EUS in diseases in many other organs will increase in the near future.

  6. Interobserver agreement on the interpretation of automated whole breast ultrasonography

    International Nuclear Information System (INIS)

    Kim, Eun Jeong; KIm, Sung Hun; Kang, Bong Joo; Kim, Yun Ju

    2014-01-01

    The purpose of this study was to prospectively evaluate the interobserver agreement on lesion characterization and the final assessment of automated whole breast ultrasonography (ABUS) images. Between March and August 2012, 172 women underwent bilateral ABUS before biopsy guided by handheld ultrasonography (HHUS) and mammography. A total of 206 breast lesions were confirmed histopathologically by biopsy. Three-dimensional volume data from ABUS scans were analyzed by two radiologists without the knowledge of HHUS results or patient clinical information. The two readers described the type, shape, orientation, margin, echogenicity, posterior acoustic features, and categorization of the final assessment of detected breast lesions. Kappa statistics were used to analyze the described characteristics of the breast lesions detected by both of the two readers. Of the 206 histopathologically confirmed lesions, reader 1 detected 166 lesions and reader 2 detected 150 lesions. A total of 145 lesions were detected by both readers using ABUS images. There was substantial agreement on shape (k=0.707), and moderate agreement on type, margin, mass orientation, echogenicity, and posterior acoustic features (k=0.592, 0.438, 0.472, 0.524, and 0.541, respectively). Breast Imaging Reporting and Data System final assessment values yielded a kappa value of 0.3971 when category subdivisions 4A, 4B, and 4C were included. With respect to the C2, C3, C4, and C5 categories, the interobserver agreement was moderate (k=0.505). ABUS is a promising diagnostic tool with a good interobserver agreement, comparable to that of HHUS.

  7. Interobserver agreement on the interpretation of automated whole breast ultrasonography

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Eun Jeong; KIm, Sung Hun; Kang, Bong Joo; Kim, Yun Ju [Dept. of Radiology, Seoul St. Mary' s Hospital, The Catholic University of Korea College of Medicine, Seoul (Korea, Republic of)

    2014-12-15

    The purpose of this study was to prospectively evaluate the interobserver agreement on lesion characterization and the final assessment of automated whole breast ultrasonography (ABUS) images. Between March and August 2012, 172 women underwent bilateral ABUS before biopsy guided by handheld ultrasonography (HHUS) and mammography. A total of 206 breast lesions were confirmed histopathologically by biopsy. Three-dimensional volume data from ABUS scans were analyzed by two radiologists without the knowledge of HHUS results or patient clinical information. The two readers described the type, shape, orientation, margin, echogenicity, posterior acoustic features, and categorization of the final assessment of detected breast lesions. Kappa statistics were used to analyze the described characteristics of the breast lesions detected by both of the two readers. Of the 206 histopathologically confirmed lesions, reader 1 detected 166 lesions and reader 2 detected 150 lesions. A total of 145 lesions were detected by both readers using ABUS images. There was substantial agreement on shape (k=0.707), and moderate agreement on type, margin, mass orientation, echogenicity, and posterior acoustic features (k=0.592, 0.438, 0.472, 0.524, and 0.541, respectively). Breast Imaging Reporting and Data System final assessment values yielded a kappa value of 0.3971 when category subdivisions 4A, 4B, and 4C were included. With respect to the C2, C3, C4, and C5 categories, the interobserver agreement was moderate (k=0.505). ABUS is a promising diagnostic tool with a good interobserver agreement, comparable to that of HHUS.

  8. Surveillance Duplex Ultrasonography of Stent Grafts for Popliteal Aneurysms.

    Science.gov (United States)

    Pineda, Danielle M; Troutman, Douglas A; Dougherty, Matthew J; Calligaro, Keith D

    2016-05-01

    Stent grafts, also known as covered stents, have become an increasingly acceptable treatment for popliteal artery aneurysms. However, endovascular exclusion confers lower primary patency compared to traditional open bypass and exclusion. The purpose of this study was to evaluate whether duplex ultrasonography (DU) can reliably diagnose failing stent grafts placed for popliteal artery aneurysms prior to occlusion. Between June 5, 2007, and March 11, 2014, 21 stent grafts (Viabahn; Gore, Flagstaff, Arizona) were placed in 19 patients for popliteal artery aneurysms. All patients had at least 1 follow-up duplex scan postoperatively. Mean follow-up was 28.9 months (9-93 months). Postoperative DU surveillance was performed in our Intersocietal Accreditation Commission noninvasive vascular laboratory at 1 week postprocedure and every 6 months thereafter. Duplex ultrasonography measured peak systolic velocities (PSVs) and ratio of adjacent PSVs (Vr) every 5 cm within the stent graft and adjacent arteries. We retrospectively classified the following factors as "abnormal DU findings": focal PSV > 300 cm/s, uniform PSVs 3.0. These DU criteria were derived from laboratory-specific data that we previously published on failing stent grafts placed for lower extremity occlusive disease. Four of the 21 stent grafts presented with symptomatic graft thrombosis within 6 months of a normal DU. Three of these 4 patients presented with rest pain and underwent thrombectomy (2) or vein bypass (1), and 1 elected for nonintervention for claudication. Our results suggest that surveillance DU using criteria established for grafts placed for occlusive disease may not be useful for predicting stent graft failure in popliteal artery aneurysms. © The Author(s) 2016.

  9. Ultrasonography of pleural effusion. The quantification of minimal detectable volume

    International Nuclear Information System (INIS)

    Sustic, A.; Medved, I.; Ekl, D.; Simic, O.; Kovac, D.; Ivanis, N.

    2001-01-01

    Background. The aim of this study was to establish a minimal volume of free thoracic fluid in the pleural space of the supine cadaver detectable by ultrasonography. Material and methods. A prospective study with an experimental model on 20 cadavers (10 male, 10 female; age 66 ±11 yr.; height 172 ±9 cm; weight 75 ±12.6 kg; body surface area (BSA) 1.87 ±0.2 m 2 ) was used. Each cadaver was punctured bilaterally in 5 th or 6 th intercostal space at the medioclavicular line with venous cannula infusing in NaCl 0,9% solution at randomised speed in the chest. During the procedure the laterodorsal part of the thoracic wall next to the pulmonal base and phrenicocostal sinus was ultrasonographically scanned. At the moment of the visualisation of anechogenic line pertaining to the free fluid between dorsal thoracic wall and lungs, the installation was stopped and the amount of injected fluid verified. Results. Minimal, by ultrasonography detectable amount of free fluid in the right pleural space was 223±52 ml with the significant positive correlation to height (r = 0.69; p < 0.001), weight (r 0.68; p < 0.01) and the BSA (r = 0.71; p < 0.001) of cadaver. Detectable volume in the left pleural space was notably smaller than contra lateral, namely 172±53 ml also with a significant correlation to the cadaver's height (r = 0.55; p < 0.05), weight (r = 0.59; p < 0.01) and BSA (r = 0.60; p < 0.01). Conclusions. The authors affirm that ultrasonographically detectable quantity of free fluid in the chest positively correlates with height, weight and BSA of cadavers, and that the measured amount in the supine position is approximately 223 ml for the right space versus 172 ml for the left pleural space. (author)

  10. Compressible Fluid Suspension Performance Testing

    National Research Council Canada - National Science Library

    Hoogterp, Francis

    2003-01-01

    ... compressible fluid suspension system that was designed and installed on the vehicle by DTI. The purpose of the tests was to evaluate the possible performance benefits of the compressible fluid suspension system...

  11. Feasibility of ultrasonography and MR arthrography during evaluation of rotator cuff injury

    International Nuclear Information System (INIS)

    Hu, Jin Guang; Lee, Jong Min; Ryeom, Hun Kyu

    2005-01-01

    To evaluate the feasibility of MR arthrography and ultrasonography in evaluating shoulder pain. The subject group consisted of all patients who visited our institute complaining of shoulder pain or instability form June 2002 to December 2004. There were a total of 92 patients with an mean age of 48. On the basis of arthroscopic results, the sensitivity, specificity, and accuracy of ultrasonography and MR arthrography were evaluated by comparing them with each other. In the diagnosis of separateness tendon tears, ultrasonography had sensitivity and specificity of 100% and 64%, respectively, whereas MR arthrography had sensitivity and specificity of 80% and 94%, respectively. Ultrasonography also had high sensitivity and specificity in the diagnosis of subscapularis tendon tears (100% and 90%). MR arthrography was appropriate for identifying glenoid labral abnormalities (sensitivity, 95% and specificity, 61%). Similar results from ultrasonography and MR arthrography were obtained in the diagnosis of subscapular tendon tears or full-thickness tears of the rotator cuff tendons (kappa value, 0.644 and 0.911). While evaluating rotator cuff abnormalities, ultrasonography was appropriate for screening, whereas MR arthrography was useful to confirm the results of the ultrasonography

  12. Comparison between mammography and ultrasonography for palpable breast mass: focusing fibroadenoma and breast cancer

    International Nuclear Information System (INIS)

    Kim, Do Kyun; Koh, Mi Kyung; Choi, Chul Soon; Chung, Soo Young; Yi, Jeong Geun; Yoon, Dae Young; Kim, Ho Chul; Bae, Sang Hoon

    1997-01-01

    The purpose of our study was to compare the diagnostic accuracy of mammography and breast ultrasonography between fibroadenoma and palpable breast cancer and to evaluate the feasibility of ultrasonography as a primary diagnostic modality to differentiate between these two tumor types. In 36 cases of fibroadenoma and 35 of breast cancer, all palpable and pathologically-proven, the diagnostic accuracy of mammography and ultrasonography was retros-pectively analysed. In fibroadenoma cases, the diagnostic accuracy of mammography and ultrasonography was 53% and 80%, respectively, and the difference was statistically significant(p=3D0.0162). In cases of breast cancer, the corresponding figures were 74% and 82%, respectively;the difference was not statistically signigicant(p-0.55). Overall, the diagnostic accuracy of mammography and ultrasonog-raphy was 63% and 82%, respectively, and this difference was statistically significant(p=3D0.0164). The total diagnostic accuracy of both studies was 90%, and this was signigicantly different(p=3D0.044) from that of ultrasonography(82%). In patients who have clinically palpable breast masses, ultrasonography can be recommended as the primary diagnostic modality, though for other breast lesions, mammography is the recommended primary modality.=20

  13. Comparison between mammography and ultrasonography for palpable breast mass: focusing fibroadenoma and breast cancer

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Do Kyun; Koh, Mi Kyung; Choi, Chul Soon; Chung, Soo Young; Yi, Jeong Geun; Yoon, Dae Young; Kim, Ho Chul; Bae, Sang Hoon [Hallym Univ. College of Medicine, Seoul (Korea, Republic of)

    1997-09-01

    The purpose of our study was to compare the diagnostic accuracy of mammography and breast ultrasonography between fibroadenoma and palpable breast cancer and to evaluate the feasibility of ultrasonography as a primary diagnostic modality to differentiate between these two tumor types. In 36 cases of fibroadenoma and 35 of breast cancer, all palpable and pathologically-proven, the diagnostic accuracy of mammography and ultrasonography was retros-pectively analysed. In fibroadenoma cases, the diagnostic accuracy of mammography and ultrasonography was 53% and 80%, respectively, and the difference was statistically significant(p=3D0.0162). In cases of breast cancer, the corresponding figures were 74% and 82%, respectively;the difference was not statistically signigicant(p-0.55). Overall, the diagnostic accuracy of mammography and ultrasonog-raphy was 63% and 82%, respectively, and this difference was statistically significant(p=3D0.0164). The total diagnostic accuracy of both studies was 90%, and this was signigicantly different(p=3D0.044) from that of ultrasonography(82%). In patients who have clinically palpable breast masses, ultrasonography can be recommended as the primary diagnostic modality, though for other breast lesions, mammography is the recommended primary modality.=20.

  14. Pretreatment Evaluation with Contrast-Enhanced Ultrasonography for Percutaneous Radiofrequency Ablation of Hepatocellular Carcinomas with Poor Conspicuity on Conventional Ultrasonography

    International Nuclear Information System (INIS)

    Kim, Ah Yeong; Lee, Min Woo; Rhim, Hyunchul; Cha, Dong Ik; Choi, Dongil; Kim, Young-sun; Lim, Hyo Keun; Cho, Seong Whi

    2013-01-01

    To determine whether pretreatment evaluation with contrast-enhanced ultrasonography (CEUS) is effective for percutaneous radiofrequency ablation (RFA) of hepatocellular carcinoma (HCC) with poor conspicuity on conventional ultrasonography (US). This retrospective study was approved by the institutional review board and informed consent was waived. From June 2008 to July 2011, 82 patients having HCCs (1.2 ± 0.4 cm) with poor conspicuity on planning US for RFA were evaluated with CEUS prior to percutaneous RFA. We analyzed our database, radiologic reports, and US images in order to determine whether the location of HCC candidates on planning US coincide with that on CEUS. To avoid incomplete ablation, percutaneous RFA was performed only when HCC nodules were identified on CEUS. The rate of technical success was assessed. The cumulative rate of local tumor progression was estimated with the use of the Kaplan-Meier method (mean follow-up: 24.0 ± 13.0 months). Among 82 patients, 73 (89%) HCCs were identified on CEUS, whereas 9 (11%) were not. Of 73 identifiable HCCs on CEUS, the location of HCC on planning US corresponded with that on CEUS in 64 (87.7%), whereas the location did not correspond in 9 (12.3%) HCCs. Technical success was achieved for all 73 identifiable HCCs on CEUS in a single (n = 72) or two (n = 1) RFA sessions. Cumulative rates of local tumor progression were estimated as 1.9% and 15.4% at 1 and 3 years, respectively. Pretreatment evaluation with CEUS is effective for percutaneous RFA of HCCs with poor conspicuity on conventional US

  15. LZ-Compressed String Dictionaries

    OpenAIRE

    Arz, Julian; Fischer, Johannes

    2013-01-01

    We show how to compress string dictionaries using the Lempel-Ziv (LZ78) data compression algorithm. Our approach is validated experimentally on dictionaries of up to 1.5 GB of uncompressed text. We achieve compression ratios often outperforming the existing alternatives, especially on dictionaries containing many repeated substrings. Our query times remain competitive.

  16. Tree compression with top trees

    DEFF Research Database (Denmark)

    Bille, Philip; Gørtz, Inge Li; Landau, Gad M.

    2013-01-01

    We introduce a new compression scheme for labeled trees based on top trees [3]. Our compression scheme is the first to simultaneously take advantage of internal repeats in the tree (as opposed to the classical DAG compression that only exploits rooted subtree repeats) while also supporting fast...

  17. Tree compression with top trees

    DEFF Research Database (Denmark)

    Bille, Philip; Gørtz, Inge Li; Landau, Gad M.

    2015-01-01

    We introduce a new compression scheme for labeled trees based on top trees. Our compression scheme is the first to simultaneously take advantage of internal repeats in the tree (as opposed to the classical DAG compression that only exploits rooted subtree repeats) while also supporting fast...

  18. A novel three-dimensional dynamic anorectal ultrasonography technique for the assessment of perineal descent, compared with defaecography.

    Science.gov (United States)

    Murad-Regadas, S M; dos Santos, D; Soares, G; Regadas, F S P; Rodrigues, L V; Buchen, G; Kenmoti, V T; Surimã, W S; Fernandes, G O da S

    2012-06-01

    The purpose of the study was to describe a novel three-dimensional dynamic anorectal ultrasonography technique (dynamic 3-DAUS) for assessment of perineal descent (PD) and establishment of normal range values, comparing it with defaecography. Secondarily, the study compares the ability of the two techniques to identify various pelvic floor dysfunctions. A prospective study was undertaken in 29 women (mean age 43 years) with obstructed defecation disorder. All patients underwent defaecography and dynamic 3-DAUS and the results were compared. Lee kappa coefficients (K) were used. On defaecography, PD > 3 cm was detected in 12 patients. On dynamic 3-DAUS, 10 of these patients had PD > 2.5 cm. Seventeen had normal PD on defaecography and PD ≤ 2.5 cm on dynamic 3-DAUS (K 0.85). Normal relaxation was observed in 10 patients and anismus in 14 with both techniques (K 0.65). Both techniques identified five patients without rectocele, two with grade I rectocele (K 0.89 and 1.00, respectively) and 10 with grade II and nine with grade III (K 0.72 and 0.77, respectively). Rectal intussusception was identified in six patients on defaecography. These were confirmed on dynamic 3-DAUS in addition to the identification of another seven cases indicating moderate agreement (K 0.46). Enterocele/sigmoidocele grade III was identified in one patient with both techniques, indicating substantial agreement (K 0.65). Dynamic 3-DAUS was shown to be a reliable technique for the assessment of PD and pelvic floor dysfunctions, identifying all disorders and confirming findings from defaecography. © 2011 The Authors. Colorectal Disease © 2011 The Association of Coloproctology of Great Britain and Ireland.

  19. Infusion tomography and ultrasonography of the gallbladder in the diagnosis of acute cholecystitis

    International Nuclear Information System (INIS)

    Karp, W.; Owman, T.; Herlin, P.; Holmin, T.

    1979-01-01

    Sixty-three patients with the clinical suspicion of acute cholecystitis were examined with infusion tomography of the gallbladder. Ultrasonography was performed in 51 of these cases. The technique and diagnostic principles of both methods are discussed. The diagnostic value of the two methods when used in combination is stressed. Thus in a case of gangrenous cholecystitis when opacification of the gallbladder wall may not appear at infusion tomography, ultrasonography may demonstrate signs of gallbladder disease. Infusion tomography, on the other hand, may be of great value if ultrasonography is not informative. (orig.) 891 AJ/orig. 892 BRE [de

  20. Shear-wave elastography in breast ultrasonography: the state of the art

    Directory of Open Access Journals (Sweden)

    Ji Hyun Youk

    2017-10-01

    Full Text Available Shear-wave elastography (SWE is a recently developed ultrasound technique that can visualize and measure tissue elasticity. In breast ultrasonography, SWE has been shown to be useful for differentiating benign breast lesions from malignant breast lesions, and it has been suggested that SWE enhances the diagnostic performance of ultrasonography, potentially improving the specificity of conventional ultrasonography using the Breast Imaging Reporting and Data System criteria. More recently, not only has SWE been proven useful for the diagnosis of breast cancer, but has also been shown to provide valuable information that can be used as a preoperative predictor of the prognosis or response to chemotherapy.

  1. Shear-wave elastography in breast ultrasonography: the state of the art

    Energy Technology Data Exchange (ETDEWEB)

    Youk, Ji Hyun; Gweon, Hye Mi; Son, Eun Ju [Dept. of Radiology, Gangnam Severance Hospital, Yonsei University College of Medicine, Seoul (Korea, Republic of)

    2017-10-15

    Shear-wave elastography (SWE) is a recently developed ultrasound technique that can visualize and measure tissue elasticity. In breast ultrasonography, SWE has been shown to be useful for differentiating benign breast lesions from malignant breast lesions, and it has been suggested that SWE enhances the diagnostic performance of ultrasonography, potentially improving the specificity of conventional ultrasonography using the Breast Imaging Reporting and Data System criteria. More recently, not only has SWE been proven useful for the diagnosis of breast cancer, but has also been shown to provide valuable information that can be used as a preoperative predictor of the prognosis or response to chemotherapy.

  2. Determination of gestational age by ultrasonography - wrong, wrong and wrong again?

    International Nuclear Information System (INIS)

    Bratlid, D.

    1991-01-01

    The article is a critical review of principal weaknesses in the current use of ultrasonography for determination of gestational age and discusses the fact that the method in its practical use disregards any biological variation in biparietal diameter. It is concluded that second trimester determination of gestational age by ultrasonography has an accuracy no greater than ±1.5 weeks. This is comparable to the accuracy of the clinical assessment of maturation in the newborn baby. Ultrasonography as the main indicator of gestational age should be used only when the pregnant woman's own menstrual history is obviously incorrect. 6 refs., 1 fig

  3. Validation of ultrasonography in detecting structural disease of the urogenital tract of the koala, Phascolarctos cinereus.

    Science.gov (United States)

    Marschner, C; Flanagan, C; Higgins, D P; Krockenberger, M B

    2014-05-01

    A retrospective review of case records of ultrasonography and necropsy outcomes of 62 koalas was used to investigate the accuracy of ultrasonography in assessing koala urogenital tract structural disease at the Port Macquarie Koala Hospital. The results showed high concordance, supporting ultrasonography as an effective tool for evaluating structural disease of the koala urogenital tract, most commonly seen with chlamydiosis. The study also illustrates the advances benefiting animal welfare that can be made by wildlife carer groups through using a scientific, evidence-based approach. © 2014 Australian Veterinary Association.

  4. Digital cinema video compression

    Science.gov (United States)

    Husak, Walter

    2003-05-01

    The Motion Picture Industry began a transition from film based distribution and projection to digital distribution and projection several years ago. Digital delivery and presentation offers the prospect to increase the quality of the theatrical experience for the audience, reduce distribution costs to the distributors, and create new business opportunities for the theater owners and the studios. Digital Cinema also presents an opportunity to provide increased flexibility and security of the movies for the content owners and the theater operators. Distribution of content via electronic means to theaters is unlike any of the traditional applications for video compression. The transition from film-based media to electronic media represents a paradigm shift in video compression techniques and applications that will be discussed in this paper.

  5. Fingerprints in compressed strings

    DEFF Research Database (Denmark)

    Bille, Philip; Gørtz, Inge Li; Cording, Patrick Hagge

    2017-01-01

    In this paper we show how to construct a data structure for a string S of size N compressed into a context-free grammar of size n that supports efficient Karp–Rabin fingerprint queries to any substring of S. That is, given indices i and j, the answer to a query is the fingerprint of the substring S......[i,j]. We present the first O(n) space data structures that answer fingerprint queries without decompressing any characters. For Straight Line Programs (SLP) we get O(log⁡N) query time, and for Linear SLPs (an SLP derivative that captures LZ78 compression and its variations) we get O(log⁡log⁡N) query time...

  6. WSNs Microseismic Signal Subsection Compression Algorithm Based on Compressed Sensing

    Directory of Open Access Journals (Sweden)

    Zhouzhou Liu

    2015-01-01

    Full Text Available For wireless network microseismic monitoring and the problems of low compression ratio and high energy consumption of communication, this paper proposes a segmentation compression algorithm according to the characteristics of the microseismic signals and the compression perception theory (CS used in the transmission process. The algorithm will be collected as a number of nonzero elements of data segmented basis, by reducing the number of combinations of nonzero elements within the segment to improve the accuracy of signal reconstruction, while taking advantage of the characteristics of compressive sensing theory to achieve a high compression ratio of the signal. Experimental results show that, in the quantum chaos immune clone refactoring (Q-CSDR algorithm for reconstruction algorithm, under the condition of signal sparse degree higher than 40, to be more than 0.4 of the compression ratio to compress the signal, the mean square error is less than 0.01, prolonging the network life by 2 times.

  7. Compressed sensing electron tomography

    International Nuclear Information System (INIS)

    Leary, Rowan; Saghi, Zineb; Midgley, Paul A.; Holland, Daniel J.

    2013-01-01

    The recent mathematical concept of compressed sensing (CS) asserts that a small number of well-chosen measurements can suffice to reconstruct signals that are amenable to sparse or compressible representation. In addition to powerful theoretical results, the principles of CS are being exploited increasingly across a range of experiments to yield substantial performance gains relative to conventional approaches. In this work we describe the application of CS to electron tomography (ET) reconstruction and demonstrate the efficacy of CS–ET with several example studies. Artefacts present in conventional ET reconstructions such as streaking, blurring of object boundaries and elongation are markedly reduced, and robust reconstruction is shown to be possible from far fewer projections than are normally used. The CS–ET approach enables more reliable quantitative analysis of the reconstructions as well as novel 3D studies from extremely limited data. - Highlights: • Compressed sensing (CS) theory and its application to electron tomography (ET) is described. • The practical implementation of CS–ET is outlined and its efficacy demonstrated with examples. • High fidelity tomographic reconstruction is possible from a small number of images. • The CS–ET reconstructions can be more reliably segmented and analysed quantitatively. • CS–ET is applicable to different image content by choice of an appropriate sparsifying transform

  8. Clinical usefulness of endoscopic ultrasonography for the evaluation of ulcerative colitis-associated tumors

    Science.gov (United States)

    Kobayashi, Kiyonori; Kawagishi, Kana; Ooka, Shouhei; Yokoyama, Kaoru; Sada, Miwa; Koizumi, Wasaburo

    2015-01-01

    AIM: To evaluate the clinical usefulness of endoscopic ultrasonography (EUS) for the diagnosis of the invasion depth of ulcerative colitis-associated tumors. METHODS: The study group comprised 13 patients with 16 ulcerative colitis (UC)-associated tumors for which the depth of invasion was preoperatively estimated by EUS. The lesions were then resected endoscopically or by surgical colectomy and were examined histopathologically. The mean age of the subjects was 48.2 ± 17.1 years, and the mean duration of UC was 15.8 ± 8.3 years. Two lesions were treated by endoscopic resection and the other 14 lesions by surgical colectomy. The depth of invasion of UC-associated tumors was estimated by EUS using an ultrasonic probe and was evaluated on the basis of the deepest layer with narrowing or rupture of the colonic wall. RESULTS: The diagnosis of UC-associated tumors by EUS was carcinoma for 13 lesions and dysplasia for 3 lesions. The invasion depth of the carcinomas was intramucosal for 8 lesions, submucosal for 2, the muscularis propria for 2, and subserosal for 1. Eleven (69%) of the 16 lesions arose in the rectum. The macroscopic appearance was the laterally spreading tumor-non-granular type for 4 lesions, sessile type for 4, laterally spreading tumor-granular type for 3, semi-pedunculated type (Isp) for 2, type 1 for 2, and type 3 for 1. The depth of invasion was correctly estimated by EUS for 15 lesions (94%) but was misdiagnosed as intramucosal for 1 carcinoma with high-grade submucosal invasion. The 2 lesions treated by endoscopic resection were intramucosal carcinoma and dysplasia, and both were diagnosed as intramucosal lesions by EUS. CONCLUSION: EUS provides a good estimation of the invasion depth of UC-associated tumors and may thus facilitate the selection of treatment. PMID:25759538

  9. [Ultrasonography-guided therapeutic procedures in the neck region].

    Science.gov (United States)

    Brzac, Hrvojka Tomić

    2009-12-01

    Minimally invasive therapeutic procedures in medicine have become very popular because of the reduced risk compared to classic surgical treatment, speed of recovery, little or no side effects, and frequently lower cost. One of these methods is ultrasonography-guided percutaneous injection of 95% ethanol (PEIT, percutaneous ethanol injection therapy), which is especially suitable for the neck region. Other methods like laser photocoagulation (ILP) or radiofrequency ablation (RFA) are more aggressive and expensive. The procedure of sterile 95% ethanol injecting is performed on an outpatient basis, without preparation. A specific amount of alcohol is injected into the lesion using a thin spinal needle, under ultrasonography guidance. The amount of alcohol depends on the size of the lesion. Complications are rare and the procedure can be repeated several times. PEIT is used in the treatment of parathyroid glands, especially secondary hyperparathyroidism, thyroid nodules (toxic adenoma, goiters and cysts), other cysts on the neck, and cervical metastases of thyroid cancer. Direct ethanol injection into the tissue causes cellular dehydration and protein denaturation, followed by the development of necrosis, fibrosis, and thrombosis of the small blood vessels. In this way, reduction or disappearance of the nodes can be achieved, along with functional normalization (for parathyroid glands and toxic adenoma), with longer or shorter disease remission or complete recovery. Today, PEIT is mostly used in dialyzed patients with secondary hyperparathyroidism. The treatment gives best results in combination with vitamin D analogs, if 1-2 parathyroid glands are enlarged, and for residual parathyroid gland after parathyroidectomy. A success rate of 50%-70% has been reported, depending on the number of enlarged parathyroid glands. Therapeutic effect is manifested in the size reduction or complete fibrozation of the gland, reduction or disappearance of vascularization, and a decrease

  10. [Diagnostic utility of endoscopic ultrasonography elastography and contrast-enhanced harmonic endoscopic ultrasonography in a patient with type 2 autoimmune pancreatitis].

    Science.gov (United States)

    Yokode, Masataka; Shiomi, Hideyuki; Itai, Ryosuke; Mikami, Sakae; Yamashita, Yukimasa; Nakano, Ryota; Ezaki, Takeshi; Masuda, Atsuhiro; Zen, Yoh

    2018-01-01

    A referring hospital diagnosed a 57-year-old man with a pancreatic head mass. The initial endoscopic ultrasonography-guided fine needle aspiration (EUS-FNA) was inconclusive because of the small sample size. Endoscopic ultrasonography elastography (EUS-EG) and contrast-enhanced harmonic endoscopic ultrasonography (CE-EUS), conducted at our institute, raised the possibility of mass-forming pancreatitis or autoimmune pancreatitis (AIP). A repeat EUS-FNA revealed inflammatory changes, including a neutrophilic duct injury suggestive of type 2 AIP. The pancreatic lesion responded well to the steroid therapy. The present case suggests that EUS-EG and CE-EUS may be useful for diagnostic exclusion of pancreatic cancers, and the combined use of EUS-EG and CE-EUS, with EUS-FNA, may help characterize inflammatory pancreatic lesions.

  11. Discrepancy between ultrasonography and hysteroscopy and histology of endometrium in postmenopausal breast cancer patients using tamoxifen

    NARCIS (Netherlands)

    Mourits, MJE; Van der Zee, AGJ; Willemse, PHB; Ten Hoor, KA; Hollema, H; De Vries, EGE

    Background. The increased risk of endometrial carcinoma following the use of tamoxifen has stimulated studies on endometrial diagnostic screening methods. In tamoxifen users the endometrial thickening observed with transvaginal ultrasonography (TVU) frequently cannot be confirmed by hysteroscopy or

  12. Comparison of Radiography and Ultrasonography for Diagnosis of Diaphragmatic Hernia in Bovines

    Directory of Open Access Journals (Sweden)

    Hakim Athar

    2010-01-01

    Full Text Available The present study was conducted on 101 animals suffering from thoracoabdominal disorders; out of which twenty seven animals (twenty six buffaloes and one cow were diagnosed with diaphragmatic hernia based on clinical signs, radiography, ultrasonography, and left flank laparorumenotomy. Radiography alone confirmed diaphragmatic hernia in 18 cases (66.67% with a sac-like structure cranial to the diaphragm. In 15 animals the sac contained metallic densities while in three cases a sac-like structure with no metallic densities was present. Ultrasonography was helpful in confirming diaphragmatic hernia in 23 cases (85.18% and ultrasonographically reticular motility was evident at the level of 4th/5th intercostal space in all the animals. B+M mode ultrasonography was used for the first time for diagnosis of diaphragmatic hernia in bovines and the results suggested that ultrasonography was a reliable diagnostic modality for diaphragmatic hernia in bovines.

  13. Ultrasonography of pediatric urogenital emergencies: review of classic and new techniques

    Directory of Open Access Journals (Sweden)

    Masahiro Kitami

    2017-07-01

    Full Text Available Urogenital emergencies are fairly common in the pediatric population, and a timely and correct diagnosis is necessary to avoid possible future infertility. In this field, ultrasonography is essential, as it has the advantages of being radiation-free and readily accessible. In particular, a high-frequency transducer allows precise evaluation of the morphology and vascularity of the scrotum, which is on the surface of the body. Beyond conventional techniques, new advanced imaging techniques have been developed, including elastography and contrast-enhanced ultrasonography. However, several pitfalls remain in the diagnosis of urogenital diseases using ultrasonography. Thus, accurate knowledge and sufficient experience with the technique are essential for making a correct diagnosis. This review provides an overview of pediatric urogenital emergency pathologies and recent ultrasonography techniques.

  14. Reliability of ultrasonography in detecting shoulder disease in patients with rheumatoid arthritis.

    LENUS (Irish Health Repository)

    Bruyn, G A W

    2009-03-01

    To assess the intra and interobserver reproducibility of musculoskeletal ultrasonography (US) among rheumatologists in detecting destructive and inflammatory shoulder abnormalities in patients with rheumatoid arthritis (RA) and to determine the overall agreement between US and MRI.

  15. Ultrasonography of pediatric urogenital emergencies: review of classic and new techniques

    Energy Technology Data Exchange (ETDEWEB)

    Kitami, Masahiro [Dept. of Diagnostic Radiology, Tohoku University Graduate School of Medicine, Sendai (Japan)

    2017-07-15

    Urogenital emergencies are fairly common in the pediatric population, and a timely and correct diagnosis is necessary to avoid possible future infertility. In this field, ultrasonography is essential, as it has the advantages of being radiation-free and readily accessible. In particular, a high-frequency transducer allows precise evaluation of the morphology and vascularity of the scrotum, which is on the surface of the body. Beyond conventional techniques, new advanced imaging techniques have been developed, including elastography and contrast-enhanced ultrasonography. However, several pitfalls remain in the diagnosis of urogenital diseases using ultrasonography. Thus, accurate knowledge and sufficient experience with the technique are essential for making a correct diagnosis. This review provides an overview of pediatric urogenital emergency pathologies and recent ultrasonography techniques.

  16. The use of multi-detector computed tomography and ultrasonography for evaluation of pleural lesions

    Directory of Open Access Journals (Sweden)

    Adel Salah Bediwy

    2015-01-01

    Conclusion: MDCT is an important noninvasive imaging tool in accurate detection and characterization of pleural lesions with complementary MPR images that solve many diagnostic problems. Ultrasonography is a safer alternative but with less diagnostic value.

  17. Imaging of juvenile spondyloarthritis. Part II: Ultrasonography and magnetic resonance imaging

    Directory of Open Access Journals (Sweden)

    Iwona Sudoł-Szopińska

    2017-09-01

    Full Text Available Juvenile spondyloarthropathies are mainly manifested by symptoms of peripheral arthritis and enthesitis. Early involvement of sacroiliac joints and spine is exceptionally rare in children; this usually happens in adulthood. Conventional radiographs visualize late inflammatory lesions. Early diagnosis is possible with the use of ultrasonography and magnetic resonance imaging. The first part of the article presented classifications and radiographic presentation of juvenile spondyloarthropathies. This part discusses changes seen on ultrasonography and magnetic resonance imaging. In patients with juvenile spondyloarthropathies, these examinations are conducted to diagnose inflammatory lesions in peripheral joints, tendon sheaths, tendons and bursae. Moreover, magnetic resonance also shows subchondral bone marrow edema, which is considered an early sign of inflammation. Ultrasonography and magnetic resonance imaging do not show specific lesions for any rheumatic disease. Nevertheless, they are conducted for early diagnosis, treatment monitoring and identifying complications. This article presents a spectrum of inflammatory changes and discusses the diagnostic value of ultrasonography and magnetic resonance imaging.

  18. Reliability of ultrasonography in detecting shoulder disease in patients with rheumatoid arthritis

    NARCIS (Netherlands)

    Bruyn, G. A. W.; Naredo, E.; Moeller, I.; Moragues, C.; Garrido, J.; de Bock, G. H.; d'Agostino, M-A; Filippucci, E.; Iagnocco, A.; Backhaus, M.; Swen, W. A. A.; Balint, P.; Pineda, C.; Milutinovic, S.; Kane, D.; Kaeley, G.; Narvaez, F. J.; Wakefield, R. J.; Narvaez, J. A.; de Augustin, J.; Schmidt, W. A.; Moller, I.; Swen, N.; de Agustin, J.

    Objective: To assess the intra and interobserver reproducibility of musculoskeletal ultrasonography ( US) among rheumatologists in detecting destructive and inflammatory shoulder abnormalities in patients with rheumatoid arthritis ( RA) and to determine the overall agreement between US and MRI.

  19. Solitary extramedullary plasmacytomas of thyroid in Hashimoto's thyroiditis: Mimicking benign cystic nodule on ultrasonography

    International Nuclear Information System (INIS)

    Kwon, Yohan; Kim, Soo Jin; Hur, Joon Ho; Park, Sung Hee; Lee, Sun Jin; Lee, Tae Jin

    2013-01-01

    Solitary extramedullary plasmacytoma (SEP) of the thyroid is uncommon and mostly occur in patients with a Hashimoto's thyroiditis (82%). We present a case on SEP of thyroid in Hashimoto's thyroiditis, which mimics growing benign cystic masses on serial ultrasonography.

  20. New patient-controlled abdominal compression method in radiography: radiation dose and image quality.

    Science.gov (United States)

    Piippo-Huotari, Oili; Norrman, Eva; Anderzén-Carlsson, Agneta; Geijer, Håkan

    2018-05-01

    The radiation dose for patients can be reduced with many methods and one way is to use abdominal compression. In this study, the radiation dose and image quality for a new patient-controlled compression device were compared with conventional compression and compression in the prone position . To compare radiation dose and image quality of patient-controlled compression compared with conventional and prone compression in general radiography. An experimental design with quantitative approach. After obtaining the approval of the ethics committee, a consecutive sample of 48 patients was examined with the standard clinical urography protocol. The radiation doses were measured as dose-area product and analyzed with a paired t-test. The image quality was evaluated by visual grading analysis. Four radiologists evaluated each image individually by scoring nine criteria modified from the European quality criteria for diagnostic radiographic images. There was no significant difference in radiation dose or image quality between conventional and patient-controlled compression. Prone position resulted in both higher dose and inferior image quality. Patient-controlled compression gave similar dose levels as conventional compression and lower than prone compression. Image quality was similar with both patient-controlled and conventional compression and was judged to be better than in the prone position.

  1. An economic evaluation of second-trimester genetic ultrasonography for prenatal detection of down syndrome.

    Science.gov (United States)

    Vintzileos, A M; Ananth, C V; Fisher, A J; Smulian, J C; Day-Salvatore, D; Beazoglou, T; Knuppel, R A

    1998-11-01

    The objective of this study was to perform an economic evaluation of second-trimester genetic ultrasonography for prenatal detection of Down syndrome. More specifically, we sought to determine the following: (1) the diagnostic accuracy requirements (from the cost-benefit point of view) of genetic ultrasonography versus genetic amniocentesis for women at increased risk for fetal Down syndrome and (2) the possible economic impact of second-trimester genetic ultrasonography for the US population on the basis of the ultrasonographic accuracies reported in previously published studies. A cost-benefit equation was developed from the hypothesis that the cost of universal genetic amniocentesis of patients at increased risk for carrying a fetus with Down syndrome should be at least equal to the cost of universal genetic ultrasonography with amniocentesis used only for those with abnormal ultrasonographic results. The main components of the equation included the diagnostic accuracy of genetic ultrasonography (sensitivity and specificity for detecting Down syndrome), the costs of the amniocentesis package and genetic ultrasonography, and the lifetime cost of Down syndrome cases not detected by the genetic ultrasonography. After appropriate manipulation of the equation a graph was constructed, representing the balance between sensitivity and false-positive rate of genetic ultrasonography; this was used to examine the accuracy of previously published studies from the cost-benefit point of view. Sensitivity analyses included individual risks for Down syndrome ranging from 1:261 (risk of a 35-year-old at 18 weeks' gestation) to 1:44 (risk of a 44-year-old at 18 weeks' gestation). This economic evaluation was conducted from the societal perspective. Genetic ultrasonography was found to be economically beneficial only if the overall sensitivity for detecting Down syndrome was >74%. Even then, the cost-benefit ratio depended on the corresponding false-positive rate. Of the 7

  2. Effect of Ultrasonography on Student Learning of Shoulder Anatomy and Landmarks.

    Science.gov (United States)

    de Vries, Kristen D; Brown, Rebecca; Mazzie, Joseph; Jung, Min-Kyung; Yao, Sheldon C; Terzella, Michael J

    2018-01-01

    Ultrasonography is becoming more common in clinical use, and it has been shown to have promising results when introduced into medical school curricula. To determine whether the use of ultrasonography as an educational supplement can improve osteopathic medical students' confidence and ability to locate 4 specific shoulder anatomical landmarks: the coracoid process, the transverse process of T1, the long head of the biceps within the bicipital groove, and the supraspinatus tendon. In this randomized controlled study, first-year osteopathic medical students aged 18 years or older were recruited and randomly assigned to a group with exposure (ultrasonography group) or without exposure (control group) to an ultrasonography machine. First, a survey was administered to measure students' baseline knowledge of shoulder anatomy, confidence in palpation skills, and opinion on anatomical landmark identification teaching methods. Next, students were shown presentations on shoulder anatomy and allowed to practice locating and palpating the specified landmarks. Students in the ultrasonography group were also given instruction on the use of ultrasonography. All students were asked to locate each of the 4 specified anatomical landmarks and then given a follow-up survey. A Mann Whitney U test was used to compare the confidence of the students before and after the intervention. A secondary analysis was performed to compare the degree of deviance from the correct position of the specified anatomical landmark between the ultrasonography and control groups. P values less than .05 were considered statistically significant. Sixty-four students participated. Compared with the control group, students in the ultrasonography group had a greater increase in confidence after the session in their ability to locate the coracoid process, bicipital tendon, and supraspinatus tendon (P=.022, P=.029, P=.44, respectively). Students in the ultrasonography group were also able to more accurately palpate

  3. HIGH-RESOLUTION ULTRASONOGRAPHY OF SHOULDER FOR ROTATOR CUFF TEAR: CORRELATION WITH ARTHROSCOPIC FINDINGS

    OpenAIRE

    Vishnumurthy H. Y; Jagdeesh K. S; Anand K; Ranoji Mane; Sanath G. Kamte; Fathima Zohra; Banerji B. H; Sathish Servegar

    2016-01-01

    INTRODUCTION Rotator cuff disease is the most common cause of shoulder pain. Ultrasonography being non-invasive, widely available, more cost-effective method and is the first choice in imaging of rotator cuff tears. Arthroscopy of shoulder is considered as the gold standard for diagnosis of rotator cuff tears. Objective of this study was to compare the diagnostic accuracy of high-resolution ultrasonography of shoulder for rotator cuff tears with arthroscopy of shoulder. METHODS...

  4. Two cases of posterior scleritis and findings of computerized tomography and ultrasonography

    International Nuclear Information System (INIS)

    Ohara, Takakazu; Uji, Yukitaka; Fujioka, Chieko; Mori, Kazuma

    1982-01-01

    Two cases of unilateral posterior scleritis, seen in 56-year-old and 68-year-old females, are reported. Computerized tomography showed characteristic findings, as follows: 1) Thickening of the posterior sclera and surrounding tissue. 2) Irregularity of the posterior wall of the eyeball. 3) Increased radiographic density in the posterior wall of the eyeball. Ultrasonography also suggested thickening of the posterior sclera. Computerized tomography and ultrasonography are considered useful in the diagnosis of posterior scleritis. (author)

  5. Comparison of ultrasonography with radiography for the detection of cervical esophageal foreign body

    OpenAIRE

    Reza Pourrashidi; Shervin Sharifkashani; Hashem Sharifian; Habib Mazaher; Peyman Salamati; Batool Ghorbani yekta

    2013-01-01

    Background: Detection of retained foreign bodies remains a significant problem in the emergency department. Foreign bodies can go undetected causing infectious complications ultrasonography is too inaccessible and expensive. The purpose of this study is comparison of ultrasonography with radiography for the detection of cervical esophageal foreign bodiesMethods: This cross-sectional study evaluated 58 patients referred with suspected upper esophageal foreign body in the Emergency Department, ...

  6. Positioning Ultrasonography Into Clinical Practice for the Management of Crohn’s Disease

    Science.gov (United States)

    Zorzi, Francesca; Lolli, Elisabetta; Pallone, Francesco

    2015-01-01

    Over the past few years, the technical evolution of ultrasound equipment, the use of oral and intravenous contrast agents, and an increase in the expertise of operators have enhanced the role that ultrasonography plays in the assessment of the gastrointestinal tract. For patients with chronic inflammatory conditions, particularly Crohn’s disease, it has been suggested that ultrasonography can be used not only for diagnostic purposes but also in disease management. These developments are reviewed in this article. PMID:27118932

  7. Computed tomography, ultrasonography, and endoscopic retrograde cholangiopancreatography in the diagnosis of pancreatic disease

    International Nuclear Information System (INIS)

    Foley, W.D.; Stewart, E.T.; Lawson, T.L.; Maher, L.; Unger, G.F.; Geenan, J.; Loguidice, J.

    1980-01-01

    A prospective study was performed comparing the sensitivity of computed tomography, ultrasonography, and endoscopic retrograde cholangiopancreatography (ERCP) in the diagnosis of pancreatic disease. Forty patients with suspected pancreatic carcinoma, acute recurrent or chronic pancreatitis, and/or jaundice were studied. CT was the most sensitive study in evaluation of pancreatitis. ERCP was most accurate in evaluation of pancreatic malignancy. Ultrasonography was the least sensitive method in detecting pancreatic disease and dilatation of the extrahepatic biliary ducts. (orig.) [de

  8. Role of ultrasonography in detecting mammographically occult breast carcinoma in women with dense breasts.

    Science.gov (United States)

    Corsetti, V; Ferrari, A; Ghirardi, M; Bergonzini, R; Bellarosa, S; Angelini, O; Bani, C; Ciatto, S

    2006-04-01

    The purpose of this study was to assess the usefulness of routine ultrasonography in women with negative mammography and dense breasts [Breast Imaging Reporting and Data System (BIRADS D3-4)]. We applied a protocol involving routine ultrasonography in a consecutive series of subjects with negative mammography and dense breasts. After evaluation by internal and external reviewers of cancers detected by ultrasonography performed to confirm negative mammography, we determined the additional cancer detection rate of ultrasonography and the cost of the protocol. Out of 17,883 total mammographies, 167 cancers were diagnosed (detection rate: 0.93%). Out of 257 suspicious mammographies, 138 cancers were detected. Out of 17,626 negative mammographies, 6,449 (36.5%) were classified as "dense breast" and underwent ultrasonography: 29 cancers were detected (detection rate: 0.44%, or 17.3% of total cancers). Out of 25 cancer cases reviewed, negative mammography and asymptomatic status was confirmed in 15 (detection rate 0.23%, or 8.9% of total cancers). The cancer detection rate was 0.11%, 0.22%, 0.32% and 0.14% for age groups 59, respectively. The cost per additional carcinoma detected by ultrasonography alone was euro 25,847.85 whereas that per examined woman was euro 21.68. The study confirms the possibility that ultrasonography can detect mammographically occult breast carcinoma in dense breasts. The evidence is insufficient to recommend this policy in routine screening practice but suggests that, at least in current clinical practice, adding ultrasonography in dense breasts may be useful despite the substantial costs.

  9. Compressive Transient Imaging

    KAUST Repository

    Sun, Qilin

    2017-04-01

    High resolution transient/3D imaging technology is of high interest in both scientific research and commercial application. Nowadays, all of the transient imaging methods suffer from low resolution or time consuming mechanical scanning. We proposed a new method based on TCSPC and Compressive Sensing to achieve a high resolution transient imaging with a several seconds capturing process. Picosecond laser sends a serious of equal interval pulse while synchronized SPAD camera\\'s detecting gate window has a precise phase delay at each cycle. After capturing enough points, we are able to make up a whole signal. By inserting a DMD device into the system, we are able to modulate all the frames of data using binary random patterns to reconstruct a super resolution transient/3D image later. Because the low fill factor of SPAD sensor will make a compressive sensing scenario ill-conditioned, We designed and fabricated a diffractive microlens array. We proposed a new CS reconstruction algorithm which is able to denoise at the same time for the measurements suffering from Poisson noise. Instead of a single SPAD senor, we chose a SPAD array because it can drastically reduce the requirement for the number of measurements and its reconstruction time. Further more, it not easy to reconstruct a high resolution image with only one single sensor while for an array, it just needs to reconstruct small patches and a few measurements. In this thesis, we evaluated the reconstruction methods using both clean measurements and the version corrupted by Poisson noise. The results show how the integration over the layers influence the image quality and our algorithm works well while the measurements suffer from non-trival Poisson noise. It\\'s a breakthrough in the areas of both transient imaging and compressive sensing.

  10. Fast Compressive Tracking.

    Science.gov (United States)

    Zhang, Kaihua; Zhang, Lei; Yang, Ming-Hsuan

    2014-10-01

    It is a challenging task to develop effective and efficient appearance models for robust object tracking due to factors such as pose variation, illumination change, occlusion, and motion blur. Existing online tracking algorithms often update models with samples from observations in recent frames. Despite much success has been demonstrated, numerous issues remain to be addressed. First, while these adaptive appearance models are data-dependent, there does not exist sufficient amount of data for online algorithms to learn at the outset. Second, online tracking algorithms often encounter the drift problems. As a result of self-taught learning, misaligned samples are likely to be added and degrade the appearance models. In this paper, we propose a simple yet effective and efficient tracking algorithm with an appearance model based on features extracted from a multiscale image feature space with data-independent basis. The proposed appearance model employs non-adaptive random projections that preserve the structure of the image feature space of objects. A very sparse measurement matrix is constructed to efficiently extract the features for the appearance model. We compress sample images of the foreground target and the background using the same sparse measurement matrix. The tracking task is formulated as a binary classification via a naive Bayes classifier with online update in the compressed domain. A coarse-to-fine search strategy is adopted to further reduce the computational complexity in the detection procedure. The proposed compressive tracking algorithm runs in real-time and performs favorably against state-of-the-art methods on challenging sequences in terms of efficiency, accuracy and robustness.

  11. SeqCompress: an algorithm for biological sequence compression.

    Science.gov (United States)

    Sardaraz, Muhammad; Tahir, Muhammad; Ikram, Ataul Aziz; Bajwa, Hassan

    2014-10-01

    The growth of Next Generation Sequencing technologies presents significant research challenges, specifically to design bioinformatics tools that handle massive amount of data efficiently. Biological sequence data storage cost has become a noticeable proportion of total cost in the generation and analysis. Particularly increase in DNA sequencing rate is significantly outstripping the rate of increase in disk storage capacity, which may go beyond the limit of storage capacity. It is essential to develop algorithms that handle large data sets via better memory management. This article presents a DNA sequence compression algorithm SeqCompress that copes with the space complexity of biological sequences. The algorithm is based on lossless data compression and uses statistical model as well as arithmetic coding to compress DNA sequences. The proposed algorithm is compared with recent specialized compression tools for biological sequences. Experimental results show that proposed algorithm has better compression gain as compared to other existing algorithms. Copyright © 2014 Elsevier Inc. All rights reserved.

  12. Comparative data compression techniques and multi-compression results

    International Nuclear Information System (INIS)

    Hasan, M R; Ibrahimy, M I; Motakabber, S M A; Ferdaus, M M; Khan, M N H

    2013-01-01

    Data compression is very necessary in business data processing, because of the cost savings that it offers and the large volume of data manipulated in many business applications. It is a method or system for transmitting a digital image (i.e., an array of pixels) from a digital data source to a digital data receiver. More the size of the data be smaller, it provides better transmission speed and saves time. In this communication, we always want to transmit data efficiently and noise freely. This paper will provide some compression techniques for lossless text type data compression and comparative result of multiple and single compression, that will help to find out better compression output and to develop compression algorithms

  13. The value of fetal ultrasonography and magnetic resonance imaging in the assessment of diaphragmatic hernias

    International Nuclear Information System (INIS)

    Amim, Bruno; Guerra, Fernando; Marchiori, Edson; Gasparetto, Emerson Leandro

    2008-01-01

    To demonstrate the relevance of ultrasonography and magnetic resonance imaging findings in the prenatal characterization and prognostic evaluation in cases of congenital diaphragmatic hernia. Materials And Methods: Fourteen pregnant women (mean gestational age = 28.7 weeks) who had undergone ultrasonography for suspicion of fetuses with congenital diaphragmatic hernia were assessed by means of magnetic resonance imaging on a 1.5 tesla equipment, following the standard protocol. Two radiologists evaluated the images and the findings were defined by consensus. Results: Twelve fetuses had left diaphragmatic hernia and two, right diaphragmatic hernia. Ultrasonography showed the fetal liver inside the thorax of five fetuses (three with left diaphragmatic hernia, and two with right diaphragmatic hernia) and magnetic resonance imaging in eight fetuses (six with left diaphragmatic hernia, and two with right diaphragmatic hernia). Stomach and small bowel loop herniation was observed in all of the fetuses with left diaphragmatic hernia (n = 12) at both magnetic resonance imaging and ultrasonography. Eight fetuses (seven with left diaphragmatic hernia and one with right diaphragmatic hernia) survived after surgical treatment. Conclusion: Ultrasonography and magnetic resonance imaging are complementary imaging methods in the evaluation of congenital diaphragmatic hernia. Magnetic resonance imaging is a helpful diagnostic method complementary to ultrasonography for evaluation of the fetal liver positioning, considering its relevance as a prognostic factor in cases of congenital diaphragmatic hernia. (author)

  14. Hydrodynamic study of syringomyelia by MRI and intraoperative ultrasonography

    International Nuclear Information System (INIS)

    Moritake, Kouzo; Takaya, Mikio; Minamikawa, Jun; Ishikawa, Masatsune; Kikuchi, Haruhiko; Minami, Shunsuke

    1989-01-01

    Syringomyelic cavities were studied with magnetic resonance imaging (MRI) in eleven patients with special reference to the hemodynamic contribution to the pathogenesis of syringomyelia. They were also studied intraoperatively with ultrasonography (USG) in five patients. Syrinx cavities combined with lumbosacral lipomyelomeningocele or with spinal stenosis did not present a flow-void phenomenon reflecting pulsatile movements of syrinx fluid. On serial MRI study in those the patients, enlargement of the syrinx cavity was not observed. Syrinx cavities occupying the caudal part of the spinal cord did not develop either. These cases were not treated surgically but followed conservatively. On the other hand, the flow-void sign in the syrinx cavities was present on MRI in patients who also had Chiari type I or type II malformations. They were treated with a syringo-subarachnoid shunt. In these cases, intraoperative USG disclosed marked fluctuation of syrinx cavity size synchronous with the motions of pulmonary ventilation. In all of them, clinical signs and symptoms improved postoperatively to various degrees. These results suggest that both the flow-void sign in the syrinx cavity on MRI and marked fluctaution of cavity size on intraoperative USG are indications for the shunt operation and support William's revised theory (1987). Fluctuation of cystic cavity size synchronous with ventilation suggests that venous pressure in the spinal subarachnoid space contributes to the pathogenesis of syringomyelic cavities. Further analysis of the fluctuation of cystic cavities by video monitoring will provide further information on the etiology and other clinical problems of syringomyelia. (author)

  15. Transcranial Doppler ultrasonography predicts cardiovascular events after TIA

    International Nuclear Information System (INIS)

    Holzer, Katrin; Sadikovic, Suwad; Esposito, Lorena; Bockelbrink, Angelina; Sander, Dirk; Hemmer, Bernhard; Poppert, Holger

    2009-01-01

    Transient ischemic attack (TIA) patients are at high vascular risk. We assessed the value of extracranial (ECD) and transcranial (TCD) Doppler and duplex ultrasonography to predict clinical outcome after TIA. 176 consecutive TIA patients admitted to the Stroke Unit were recruited in the study. All patients received diffusion-weighted imaging, standardized ECD and TCD. At a median follow-up of 27 months, new vascular events were recorded. 22 (13.8%) patients experienced an ischemic stroke or TIA, 5 (3.1%) a myocardial infarction or acute coronary syndrome, and 5 (3.1%) underwent arterial revascularization. ECD revealed extracranial ≥ 50% stenosis or occlusions in 34 (19.3%) patients, TCD showed intracranial stenosis in 15 (9.2%) and collateral flow patterns due to extracranial stenosis in 5 (3.1%) cases. Multivariate analysis identified these abnormal ECD and TCD findings as predictors of new cerebral ischemic events (ECD: hazard ratio (HR) 4.30, 95% confidence interval (CI) 1.75 to 10.57, P = 0.01; TCD: HR 4.73, 95% CI 1.86 to 12.04, P = 0.01). Abnormal TCD findings were also predictive of cardiovascular ischemic events (HR 18.51, 95% CI 3.49 to 98.24, P = 0.001). TIA patients with abnormal TCD findings are at high risk to develop further cerebral and cardiovascular ischemic events

  16. Ultrasonography and computed tomography in diffuse liver disease with cholestasis

    International Nuclear Information System (INIS)

    Partanen, K.; Pikkarainen, P.; Pasanen, P.; Alhava, E.; Soimakallio, S.; Kuopio Univ. Central Hospital; Kuopio Univ. Central Hospital

    1990-01-01

    Ultrasonography (US) and computed tomography (CT) were performed on respectively 67 and 42 (altogether 72) patients, for the assessment of intrahepatic cholestasis. The diagnostic ability to differentiate between malignant (17 patients) and benign (55 patients) liver disease was analyzed. Coarse echogenicity of the liver led to inconclusive results in differentiating between cirrhosis (2 out of 29 patients) and malignant infiltration (4 out of 15 patients) by US. Other benign liver diseases in 23 patients, including acute hepatitis, chronic active hepatitis, fatty liver, and liver congestion, were correctly interpreted as benign. CT correctly disclosed malignant liver disease in all cases. A false positive diagnosis of malignancy was encountered in 4 (out of 17) patients with decompensated hepatic cirrhosis because of non-homogeneous expansive areas on CT in 3 cases. The true cause was in 2 patients non-uniform fatty infiltration, and in one patient with acute hepatitis A, small hypodense lesions. Among cholestatic patients, decompensated cirrhosis and malignant liver infiltration could not always be differentiated on US or CT. (orig.)

  17. Deep venous thrombus characterization: ultrasonography, elastography and scattering operator

    Directory of Open Access Journals (Sweden)

    Thibaud Berthomier

    2017-04-01

    Full Text Available A thrombus or a blood clot is the result of blood coagulation which is a natural process to prevent bleeding. An inappropriate formation of a thrombus in a deep vein is known as Deep Venous Thrombosis (DVT. The main complication of a DVT is a Pulmonary Embolism (PE which occurs when a thrombus breaks loose and travels to the lungs. DVT, PE, or both are also known as Venous thromboembolism (VTE. It affects an estimated 300,000–600,000 Individuals just in the United States per year and can cause considerable morbidity and mortality. This multifactorial disease related to advanced age, immobility, surgery or obesity is an important public health issue. Our project is looking to link the VTE epidemiology (risk factors, patient history, PE to the thrombus structure. To reach our goals, we are collecting ultrasonography (echogenicity and elastography (stiffness of human thrombus. This manuscript describes our approach to create and preprocess a database using Toshiba Aplio 500. Our approaches to characterize the thrombus structure with ultrasound images are also described. The feature extraction is made with the scattering operator. Obtained features are then reduced using Principal Component Analysis and are analyzed to evaluate our approach.

  18. Ultrasonography findings and tumour quantification in patients with pseudomyxoma peritonei

    International Nuclear Information System (INIS)

    Krause, J.; Bergman, A.; Graf, W.; Nilsson, A.; Mahteme, H.

    2012-01-01

    Pseudomyxoma peritonei (PMP) is a disease with various clinical presentations and the diagnostic value of ultrasonography (US) is under investigated. The purpose of this study was to identify the most common US finding in PMP and to investigate US sensitivity, specificity, positive and negative predictive value in quantifying tumour burden in different abdomino-pelvic regions in PMP patients. Between February 2006 and December 2008, 54 patients were treated with cytoreductive surgery (CRS) and hyperthermic intraperitoneal chemotherapy (HIPEC) due to PMP. The results from preoperative US examination with and without intravenously administrated contrast (SonoVue) were compared to surgical findings. The mean US peritoneal cancer index (PCI) was 6 (range 0–25) and the surgical PCI was 18 (range 3–27) p < 0.0001. The histo-pathological subtypes did not influence the US findings. Ascites, bowel loops adhesions and omental cake were mostly visualised correctly by US. The sensitivity of US in quantification of tumour nodules was 91.5% (range 74–100%) and specificity was 33.8% (range 18–55%). The positive predictive value of US examination in PMP was 22% (range 11–44%) and the negative predictive value was 93% (range 77–100%). US can detect the most common PMP findings (ascites and omental cake). The sensitivity of US to quantify PMP tumour burden in different abdominio-pelvic region was relatively high, however, this imaging tool had low specificity.

  19. Availability of ultrasonography in health examination of atomic bomb survivors

    International Nuclear Information System (INIS)

    Kato, Masafumi; Mito, Kazuyo; Ishibashi, Shinzo; Takayama, Sadamatsu; Ito, Chikako

    1989-01-01

    A total of 1424 A-bomb survivors, consisting of 596 men and 827 women, participated in the health screening during the period from August 1985 through March 1988. Abnormal findings of ultrasonography were observed in 64% for men and 53% for women. According to age groups, the incidence of abnormal findings tended to increase with aging in men. In women, it was independent of aging. The most common abnormal finding was billiary calculus (13%), followed by renal cyst, splenomegaly, hepatomegaly, and liver disturbance. Suspected hepatic tumor, hepatomegaly, liver disturbance, fatty liver, and liver cirrhosis were more frequent in men than women. The incidence of billiary or gallbladder calculus was significantly higher in women than men. Among 56 survivors (13%) with suspected malignancy, it was confirmed in 25 survivors (19 with primary or metastatic liver carcinoma, 3 with renal cell carcinoma, 2 with cholangiocarcinoma, and one with pancreatic carcinoma). Of 9 hepatoma patients, 8 had an increased alpha-fetoprotein. Hematologic findings were normal in all of the patients with renal cell carcinoma. (N.K.)

  20. Fetal central nervous system anomalies: fast MRI vs ultrasonography

    International Nuclear Information System (INIS)

    Yang Wenzhong; Xia Liming; Yang Minjie; Feng Dingyi; Hu Junwu; Zou Mingli; Wang Chengyuan; Chen Xinlin; Yang Xiaohong

    2006-01-01

    Objective: To evaluate the ability of fast MRI to detect fetal central nervous system (CNS) anomalies and to compare its performance with that of prenatal ultrasonography (US). Methods Forty-eight pregnant women were detected by conventional prenatal US and MRI. Twenty-two fetuses with CNS anomalies were conformed by autopsy and follow-up. The MR and US appearances of fetal CNS structure were compared to each other and to that of autopsy. Results: A total of 26 CNS anomalies were identified by autopsy (n=17) and follow-up (n=9) including anencephaly (n=6), rachischisis (n=2), encephalocele (n=3), congenital hydrocephalus (n=7), alobar holoprosencephaly (n=1), porencephalia (n=3), arachnoid cyst (n=2) and choroids plexus cyst (n=2). US diagnosed 24 CNS anomalies, the correct diagnostic rate was 92.3%, the false-positive rate was 3.8%, the missed-diagnostic rate was 3.8%. MRI diagnosed 23 CNS anomalies, the correct-diagnostic rate was 88.5%, the false-positive rate was 3.8% ,the missed-diagnostic rate was 7.7%. There was no difference between US and MRI (P>0.05), but MRI have larger FOV, higher tissues resolution, and can demonstrate gray-white matter in detail. Conclusions: MR imaging has a similar sensitivity to that of US in the detection of fetal CNS anomalies. (authors)

  1. Ultrasonography and arthrography in rotator cuff lesions: algorithmic approach

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Eui Jong; Ryu, Kyung Nam; Lee, Sun Wha; Lim, Jae Hoon; Rhee, Yong Girl [Kyung Hee University Hospital, Seoul (Korea, Republic of); Yu, Pil Mun [Dankuk University College of Medicine, Chenona (Korea, Republic of)

    1992-11-15

    Twenty-six patients with chief complaint of shoulder pain who underwent both ultrasonographic examination and arthrography of the shoulder were analyzed. Ten out of 12 cases with clinical impression of frozen shoulder, showed normal findings on the ultrasonographic examination of the shoulder. Among these ten cases, nine cases showed adhesive capsulitis and one case showed rotator cuff tear on arthrography. Among six cases with the clinical impression of rotator cuff tear, five cases showed rotator cuff tear and one case showed combined calcific tendinitis and adhesive capsulitis on ultrasonographic examination. In arthrography, four cases of rotator cuff tear, one case of calcific tendinitis and biceps tendinitis and one case of normal finding were diagnosed. For the remaining eight cases in the ultrasonographic examination, normal finding or biceps tendinitis were found and for the remaining of the cases in arthrography adhesive capsulitis were found. With the above results, we recommend that the shoulder ultrasonography as the first line diagnostic modality for a patient with chief complaint of shoulder pain.

  2. Ultrasonography and arthrography in rotator cuff lesions: algorithmic approach

    International Nuclear Information System (INIS)

    Kim, Eui Jong; Ryu, Kyung Nam; Lee, Sun Wha; Lim, Jae Hoon; Rhee, Yong Girl; Yu, Pil Mun

    1992-01-01

    Twenty-six patients with chief complaint of shoulder pain who underwent both ultrasonographic examination and arthrography of the shoulder were analyzed. Ten out of 12 cases with clinical impression of frozen shoulder, showed normal findings on the ultrasonographic examination of the shoulder. Among these ten cases, nine cases showed adhesive capsulitis and one case showed rotator cuff tear on arthrography. Among six cases with the clinical impression of rotator cuff tear, five cases showed rotator cuff tear and one case showed combined calcific tendinitis and adhesive capsulitis on ultrasonographic examination. In arthrography, four cases of rotator cuff tear, one case of calcific tendinitis and biceps tendinitis and one case of normal finding were diagnosed. For the remaining eight cases in the ultrasonographic examination, normal finding or biceps tendinitis were found and for the remaining of the cases in arthrography adhesive capsulitis were found. With the above results, we recommend that the shoulder ultrasonography as the first line diagnostic modality for a patient with chief complaint of shoulder pain

  3. Characterisation of focal liver lesions with contrast enhanced ultrasonography

    International Nuclear Information System (INIS)

    Dietrich, Christoph F.

    2004-01-01

    Ultrasound contrast agents (USCA) have improved the detection rate of liver tumours in recent years. Conventional ultrasound has been reported to be relatively unreliable in the characterisation of liver tumours. SonoVue [reg] (Bracco Imaging Spa) has been shown to be particularly advantageous in the differentiation of benign and malignant liver tumours and, therefore, possibly represents a new cost-effective competitive alternative to other liver imaging modalities (e.g. computed tomography and magnetic resonance imaging), thus allowing these important technologies to be available for other indications (e.g. brain, thorax). More detailed and specific liver tumour characterisation is possible in about 80% of liver tumours due to typical vascularity and perfusion patterns. The role of USCA for better characterisation, which is possible through the analysis of flow characteristics in real time, places a particular emphasis on agent use. Contrast enhanced real-time imaging techniques with SonoVue [reg] allow real-time analysis of tumour perfusion in patients with liver lesions. Liver tumours known to be hyperperfused in the arterial phase (e.g. focal nodular hyperplasia, hepatocellular adenoma and carcinoma, and hyperperfused metastases) can be better detected and characterised. Hypoperfused tumours (e.g. liver metastases of the gastrointestinal tract) can be recognised in the portal venous phase as less perfused 'black spots'. In this article we discuss liver tumour characterisation by contrast enhanced ultrasonography

  4. Utility of Ultrasonography for Urinary Tract Infections of Infants

    Energy Technology Data Exchange (ETDEWEB)

    Yoon, Chul Ho; Kim, Yun Jeong [Dongnam Health Univ., Seoul (Korea, Republic of)

    2009-06-15

    In this study, we investigated utility of ultrasonography for urinary tract infections of infants. The results of the research is as follows : 1. The number of infants under one year old was 100 out of 122 infants who were diagnosed as a unitary infection. The ratio of males to females was 1.7 : 1. Seventy-seven infants who underwent three kinds of radiologic examinations such as kidney sonography (51%), {sup 99m}TC DMSA-scan (42%), and VCUG (22%). 2. In comparison of correlation between kidney sonography and VCUG, the sensitivity of kidney sonography was 82% while the specificity of kidney sonography was 58%. In comparison of correlation between kidney sonography and {sup 99m}TC DMSA-scan, the sensitivity of kidney sonography was 66% while the specificity of kidney sonography was 67%. 3. Utility of kidney sonography showed the highest efficiency when we considered pain, discomfort, a sense of shame, psychological stress when infants may undergo at the examination, side-effect of a contrast agent after the examination, and complication of exposure to radiation.

  5. The usefulness of transvaginal ultrasonography and MRI in endometrial carcinoma

    International Nuclear Information System (INIS)

    Yoshihara, Eisuke

    1992-01-01

    Between October 1988 and March 1991, 29 patients with endometrial carcinoma had both transvaginal ultrasonography (TVUS) and magnetic resonance imaging (MRI) performed following hysterectomy at the Department of Gynecology and Obstetrics, Okayama University Medical School. The findings were compared with the pathological findings to determine the usefulness of each method. The sensitivity of detecting myometrial invasion was 100% by TVUS and 96% by MRI. The accuracy was 86% by each method. The depth of myometrial invasion was classified into 3 degrees [no myometrial invasion, superficial invasion (≤1/2), deep invasion (>1/2)]. The correct diagnostic rate was 86% by TVUS and MRI. The minimum width and the minimum/maximum width ratio of the intact myometrium obtained by each method in the pathological deep invasion group were significantly lower than those obtained in the other two groups (p<0.01). The sensitivity, the accuracy and the specificity for detecting cervical invasion were 89%, 93% and 95% by both methods. There was no difference between TVUS and MRI for diagnosing myometrial and cervical invasion of endometrial carcinoma. (author)

  6. Contrast-Enhanced Endoscopic Ultrasonography for Pancreatic Tumors

    Directory of Open Access Journals (Sweden)

    Yasunobu Yamashita

    2015-01-01

    Full Text Available Objectives. To investigate the usefulness of contrast-enhanced endoscopic ultrasonography (CE-EUS for histological differentiation of pancreatic tumors. Methods. CE-EUS was performed for consecutive patients having a pancreatic solid lesion, and tumors were classified into three vascular patterns (hypervascular, isovascular, and hypovascular at two time phases (early-phase and late-phase. Correlation between vascular patterns and histopathology of resected pancreatic cancer (PC tissues was ascertained. Results. The final diagnoses of 147 examined tumors were PC (n=109, inflammatory mass (n=11, autoimmune pancreatitis (n=9, neuroendocrine tumor (n=8, and others (n=10. In late-phase images, 104 of 109 PCs had the hypovascular pattern, for a diagnostic sensitivity and specificity of 94% and 71%, respectively. Of 28 resected PCs, 10 had isovascular, and 18 hypovascular, patterns on the early-phase image. Early-phase isovascular PCs were more likely to be differentiated than were early-phase hypovascular PCs (6 well and 4 moderately differentiated versus 3 well, 14 moderately, and 1 poorly differentiated, P=0.028. Immunostaining revealed that hypovascular areas of early-phase images reflected heterogeneous tumor cells with fibrous tissue, necrosis, and few vessels. Conclusion. CE-EUS could be useful for distinguishing PC from other solid pancreatic lesions and for histological differentiation of PCs.

  7. Clinical diagnostic potentials of thyroid ultrasonography and scintigraphy; An evaluation

    Energy Technology Data Exchange (ETDEWEB)

    Torizuka, Tatsuo; Kasagi, Kanji; Hatabu, Hiroto; Misaki, Takashi; Iida, Yasuhiro; Konishi, Junji (Kyoto Univ. (Japan). Hospital); Endo, Keigo

    1993-06-01

    This prospective study was designed to evaluate the potential contributions of high resolution ultrasonography (US) and Tc-99m scintigraphy in the routine diagnosis of thyroid disease. The diagnostic impacts of US and Tc-99m scintigraphy results in 177 patients visiting our thyroid clinic were assessed and scored according to the following criteria: when the information provided by either test supported, confirmed or changed the initial clinical diagnosis, they received scores of 2, 3 and 4 respectively, while score 1 was given when the test itself was useless for the differential diagnosis. US identified focal lesions that both palpation and scintigraphy had failed to detect in 14 (12.1%) of 116 patients with diffuse thyroid diseases, suggesting the necessity of Hashimoto's thyroiditis, adenoma, adenocarcinoma and adenomatous goiter, and vice versa in the diagnosis of hyperthyroid and euthyroid Graves's diseases. Thus, the advantages of US over scintigraphy for morphological evaluation were confirmed. US was particularly useful for the differential diagnosis of adenomatous goiter from Hashimoto's thyroiditis or a single nodular disease. In contrast, scintigraphy gave functional images, being especially helpful for the differential diagnosis of thyrotoxicosis. (author).

  8. Utility of Ultrasonography for Urinary Tract Infections of Infants

    International Nuclear Information System (INIS)

    Yoon, Chul Ho; Kim, Yun Jeong

    2009-01-01

    In this study, we investigated utility of ultrasonography for urinary tract infections of infants. The results of the research is as follows : 1. The number of infants under one year old was 100 out of 122 infants who were diagnosed as a unitary infection. The ratio of males to females was 1.7 : 1. Seventy-seven infants who underwent three kinds of radiologic examinations such as kidney sonography (51%), 99m TC DMSA-scan (42%), and VCUG (22%). 2. In comparison of correlation between kidney sonography and VCUG, the sensitivity of kidney sonography was 82% while the specificity of kidney sonography was 58%. In comparison of correlation between kidney sonography and 99m TC DMSA-scan, the sensitivity of kidney sonography was 66% while the specificity of kidney sonography was 67%. 3. Utility of kidney sonography showed the highest efficiency when we considered pain, discomfort, a sense of shame, psychological stress when infants may undergo at the examination, side-effect of a contrast agent after the examination, and complication of exposure to radiation.

  9. Imperforate Anus: Determination of Type Using Transperineal Ultrasonography

    International Nuclear Information System (INIS)

    Choi, Young Hun; Kim, In One; Cheon, Jung Eun; Kim, Woo Sun; Yeon, Kyung Mo

    2009-01-01

    This study was designed to assess the usefulness of transperineal ultrasonography (US) for the determination of imperforate anus (IA) type. From January 2000 to December 2004, 46 of 193 patients with an IA underwent transperineal US prior to corrective surgery. Sonographic findings were reviewed to identify the presence of internal fistulas and to determine 'distal rectal pouch to perineum (P-P)' distances. IA types were determined based on the sonographic findings, and the diagnostic accuracy of transperineal US was evaluated based on surgical findings. Of the 46 patients, 17 patients were surgically confirmed as having a high-type IA, three patients were confirmed as having an intermediate-type IA and 26 patients were confirmed as having a low-type IA. The IA type was correctly diagnosed by the use of transperineal US in 39 of the 46 patients (85%). In 14 of the 17 patients with a high-type IA, internal fistulas were correctly identified. All cases with a P-P distance > 16 mm were high-type IAs and all cases with a P-P distance < 5 mm were low-type IAs. Transperineal US is a good diagnostic modality for the identification of internal fistulas in cases of high-type IA and for defining the IA level

  10. Analysis by compression

    DEFF Research Database (Denmark)

    Meredith, David

    MEL is a geometric music encoding language designed to allow for musical objects to be encoded parsimoniously as sets of points in pitch-time space, generated by performing geometric transformations on component patterns. MEL has been implemented in Java and coupled with the SIATEC pattern...... discovery algorithm to allow for compact encodings to be generated automatically from in extenso note lists. The MEL-SIATEC system is founded on the belief that music analysis and music perception can be modelled as the compression of in extenso descriptions of musical objects....

  11. Compressive Fatigue in Wood

    DEFF Research Database (Denmark)

    Clorius, Christian Odin; Pedersen, Martin Bo Uhre; Hoffmeyer, Preben

    1999-01-01

    An investigation of fatigue failure in wood subjected to load cycles in compression parallel to grain is presented. Small clear specimens of spruce are taken to failure in square wave formed fatigue loading at a stress excitation level corresponding to 80% of the short term strength. Four...... frequencies ranging from 0.01 Hz to 10 Hz are used. The number of cycles to failure is found to be a poor measure of the fatigue performance of wood. Creep, maximum strain, stiffness and work are monitored throughout the fatigue tests. Accumulated creep is suggested identified with damage and a correlation...

  12. Compressive full waveform lidar

    Science.gov (United States)

    Yang, Weiyi; Ke, Jun

    2017-05-01

    To avoid high bandwidth detector, fast speed A/D converter, and large size memory disk, a compressive full waveform LIDAR system, which uses a temporally modulated laser instead of a pulsed laser, is studied in this paper. Full waveform data from NEON (National Ecological Observatory Network) are used. Random binary patterns are used to modulate the source. To achieve 0.15 m ranging resolution, a 100 MSPS A/D converter is assumed to make measurements. SPIRAL algorithm with canonical basis is employed when Poisson noise is considered in the low illuminated condition.

  13. Metal Hydride Compression

    Energy Technology Data Exchange (ETDEWEB)

    Johnson, Terry A. [Sandia National Lab. (SNL-CA), Livermore, CA (United States); Bowman, Robert [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Smith, Barton [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Anovitz, Lawrence [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Jensen, Craig [Hawaii Hydrogen Carriers LLC, Honolulu, HI (United States)

    2017-07-01

    Conventional hydrogen compressors often contribute over half of the cost of hydrogen stations, have poor reliability, and have insufficient flow rates for a mature FCEV market. Fatigue associated with their moving parts including cracking of diaphragms and failure of seal leads to failure in conventional compressors, which is exacerbated by the repeated starts and stops expected at fueling stations. Furthermore, the conventional lubrication of these compressors with oil is generally unacceptable at fueling stations due to potential fuel contamination. Metal hydride (MH) technology offers a very good alternative to both conventional (mechanical) and newly developed (electrochemical, ionic liquid pistons) methods of hydrogen compression. Advantages of MH compression include simplicity in design and operation, absence of moving parts, compactness, safety and reliability, and the possibility to utilize waste industrial heat to power the compressor. Beyond conventional H2 supplies of pipelines or tanker trucks, another attractive scenario is the on-site generating, pressuring and delivering pure H2 at pressure (≥ 875 bar) for refueling vehicles at electrolysis, wind, or solar generating production facilities in distributed locations that are too remote or widely distributed for cost effective bulk transport. MH hydrogen compression utilizes a reversible heat-driven interaction of a hydride-forming metal alloy with hydrogen gas to form the MH phase and is a promising process for hydrogen energy applications [1,2]. To deliver hydrogen continuously, each stage of the compressor must consist of multiple MH beds with synchronized hydrogenation & dehydrogenation cycles. Multistage pressurization allows achievement of greater compression ratios using reduced temperature swings compared to single stage compressors. The objectives of this project are to investigate and demonstrate on a laboratory scale a two-stage MH hydrogen (H2) gas compressor with a

  14. Double contrast-enhanced ultrasonography in the detection of periampullary cancer: Comparison with B-mode ultrasonography and MR imaging

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, Ting [Department of Medical Image Center, Zhujiang Hospital, Southern Medical University, Guangzhou (China); Department of Medical Ultrasonics, The Third Affiliated Hospital, Sun Yat-sen University, Guangzhou (China); Su, Zhong-zhen; Wang, Ping; Wu, Tao [Department of Medical Ultrasonics, The Third Affiliated Hospital, Sun Yat-sen University, Guangzhou (China); Tang, Wen [Department of Radiology, The Third Affiliated Hospital, Sun Yat-sen University, Guangzhou (China); Xu, Er-jiao; Ju, Jin-xiu [Department of Medical Ultrasonics, The Third Affiliated Hospital, Sun Yat-sen University, Guangzhou (China); Quan, Xian-yue, E-mail: quanxianyue2014@163.com [Department of Medical Image Center, Zhujiang Hospital, Southern Medical University, Guangzhou (China); Zheng, Rong-qin, E-mail: zhengrq@mail.sysu.edu.cn [Department of Medical Ultrasonics, The Third Affiliated Hospital, Sun Yat-sen University, Guangzhou (China)

    2016-11-15

    Purpose: To investigate the value of double contrast-enhanced ultrasonography (DCEUS) in the detection of periampullary cancer. Materials and methods: Ninety-nine patients with surgery or biopsy-proven periampullary cancer who underwent both DCEUS and magnetic resonance imaging (MRI) examinations before operation were enrolled in our study. DCEUS in which intravenous microbubbles were used in combination with oral contrast agent and MRI were performed preoperatively to make a detection diagnosis of periampullary cancer. The sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV) and accuracy of DCEUS, B-mode ultrasonography (BUS) and MRI were calculated and compared. Receiver operating characteristic (ROC) curves were used to evaluate the accuracy of BUS, DCEUS and MRI in the detection. Stratified analyses were performed for different pathological types and different sizes of periampullary lesions. The inter- and intra-observer reliability of DCEUS for cancer detection was also investigated. Result: There were no significant differences in sensitivity, specificity, PPV, NPV or accuracy between DCEUS and MRI (all P > 0.05). ROC analysis showed that the accuracy of DCEUS or MRI was higher than that of BUS (P < 0.001), while no significant differences were noted in the accuracy between DCEUS and MR. In the 76 cases of periampullary cancer, DCEUS appeared to be superior to BUS for ampullary carcinoma, duodenum carcinoma and for lesions with an average diameter of less than 3 cm. DCEUS appeared equal to BUS in other groups. No significant differences were noted between DCEUS and MRI in the stratified analysis. A considerably well agreement between DCEUS and MRI was obtained using Kappa analysis (k = 0.649, P < 0.001). The intra- and inter-observer reproducibility were both good for detection of periampullary cancer by DCEUS, with a Kappa values of 0.783 (P < 0.01) and 0.732 (P < 0.01), respectively. Conclusion: DCEUS provides an

  15. On arbitrarily graded rings

    Indian Academy of Sciences (India)

    58

    paper is devoted to the study of arbitrary rings graded through arbitrary sets. .... which recover certain multiplicative relations among the homogeneous components ... instance the case in which the grading set A is an Abelian group, where the ...

  16. Graded manifolds and supermanifolds

    International Nuclear Information System (INIS)

    Batchelor, M.

    1984-01-01

    In this paper, a review is presented on graded manifolds and supermanifolds. Many theorems, propositions, corrollaries, etc. are given with proofs or sketch proofs. Graded manifolds, supereuclidian space, Lie supergroups, etc. are dealt with

  17. Free compression tube. Applications

    Science.gov (United States)

    Rusu, Ioan

    2012-11-01

    During the flight of vehicles, their propulsion energy must overcome gravity, to ensure the displacement of air masses on vehicle trajectory, to cover both energy losses from the friction between a solid surface and the air and also the kinetic energy of reflected air masses due to the impact with the flying vehicle. The flight optimization by increasing speed and reducing fuel consumption has directed research in the aerodynamics field. The flying vehicles shapes obtained through studies in the wind tunnel provide the optimization of the impact with the air masses and the airflow along the vehicle. By energy balance studies for vehicles in flight, the author Ioan Rusu directed his research in reducing the energy lost at vehicle impact with air masses. In this respect as compared to classical solutions for building flight vehicles aerodynamic surfaces which reduce the impact and friction with air masses, Ioan Rusu has invented a device which he named free compression tube for rockets, registered with the State Office for Inventions and Trademarks of Romania, OSIM, deposit f 2011 0352. Mounted in front of flight vehicles it eliminates significantly the impact and friction of air masses with the vehicle solid. The air masses come into contact with the air inside the free compression tube and the air-solid friction is eliminated and replaced by air to air friction.

  18. Photon compression in cylinders

    International Nuclear Information System (INIS)

    Ensley, D.L.

    1977-01-01

    It has been shown theoretically that intense microwave radiation is absorbed non-classically by a newly enunciated mechanism when interacting with hydrogen plasma. Fields > 1 Mg, lambda > 1 mm are within this regime. The predicted absorption, approximately P/sub rf/v/sub theta/sup e/, has not yet been experimentally confirmed. The applications of such a coupling are many. If microwave bursts approximately > 5 x 10 14 watts, 5 ns can be generated, the net generation of power from pellet fusion as well as various military applications becomes feasible. The purpose, then, for considering gas-gun photon compression is to obtain the above experimental capability by converting the gas kinetic energy directly into microwave form. Energies of >10 5 joules cm -2 and powers of >10 13 watts cm -2 are potentially available for photon interaction experiments using presently available technology. The following topics are discussed: microwave modes in a finite cylinder, injection, compression, switchout operation, and system performance parameter scaling

  19. Fingerprints in Compressed Strings

    DEFF Research Database (Denmark)

    Bille, Philip; Cording, Patrick Hagge; Gørtz, Inge Li

    2013-01-01

    The Karp-Rabin fingerprint of a string is a type of hash value that due to its strong properties has been used in many string algorithms. In this paper we show how to construct a data structure for a string S of size N compressed by a context-free grammar of size n that answers fingerprint queries...... derivative that captures LZ78 compression and its variations) we get O(loglogN) query time. Hence, our data structures has the same time and space complexity as for random access in SLPs. We utilize the fingerprint data structures to solve the longest common extension problem in query time O(logNlogℓ) and O....... That is, given indices i and j, the answer to a query is the fingerprint of the substring S[i,j]. We present the first O(n) space data structures that answer fingerprint queries without decompressing any characters. For Straight Line Programs (SLP) we get O(logN) query time, and for Linear SLPs (an SLP...

  20. Compressive sensing in medical imaging.

    Science.gov (United States)

    Graff, Christian G; Sidky, Emil Y

    2015-03-10

    The promise of compressive sensing, exploitation of compressibility to achieve high quality image reconstructions with less data, has attracted a great deal of attention in the medical imaging community. At the Compressed Sensing Incubator meeting held in April 2014 at OSA Headquarters in Washington, DC, presentations were given summarizing some of the research efforts ongoing in compressive sensing for x-ray computed tomography and magnetic resonance imaging systems. This article provides an expanded version of these presentations. Sparsity-exploiting reconstruction algorithms that have gained popularity in the medical imaging community are studied, and examples of clinical applications that could benefit from compressive sensing ideas are provided. The current and potential future impact of compressive sensing on the medical imaging field is discussed.

  1. Generalized massive optimal data compression

    Science.gov (United States)

    Alsing, Justin; Wandelt, Benjamin

    2018-05-01

    In this paper, we provide a general procedure for optimally compressing N data down to n summary statistics, where n is equal to the number of parameters of interest. We show that compression to the score function - the gradient of the log-likelihood with respect to the parameters - yields n compressed statistics that are optimal in the sense that they preserve the Fisher information content of the data. Our method generalizes earlier work on linear Karhunen-Loéve compression for Gaussian data whilst recovering both lossless linear compression and quadratic estimation as special cases when they are optimal. We give a unified treatment that also includes the general non-Gaussian case as long as mild regularity conditions are satisfied, producing optimal non-linear summary statistics when appropriate. As a worked example, we derive explicitly the n optimal compressed statistics for Gaussian data in the general case where both the mean and covariance depend on the parameters.

  2. Prenatal Diagnosis of Penoscrotal Hypospadia in Third Trimester by Two- and Three-Dimensional Ultrasonography: A Case Report

    Directory of Open Access Journals (Sweden)

    Lívia Teresa Moreira Rios

    2012-01-01

    Full Text Available Hypospadia is an abnormal development of the corpus spongiosum, that involves cavernosa urethra, as a result of an inadequate fusion of the urethral folds. The incidence ranges from 0.2 to 4.1 per 1,000 live births. Among the markers of hypospadia, isolated ventral or lateral curvature of the penis associated with shortening are the most important markers and, in severe cases, can result in the classic “tulip sign.” The diagnosis of hypospadia is uncommon unless there is a routine of detailed analysis of fetal genitalia morphology. The prenatal diagnosis is of great importance for genetic counseling and allows better planning of postnatal treatment. The three-dimensional ultrasonography (3DUS in rendering mode enables better comprehension of the pathology by parents, facilitating postnatal planning. We report a case of penoscrotal hypospadia diagnosed at 33 weeks of gestation, suspected due to the absence of testicles in the scrotum and difficulty of penis visualization. We emphasize the findings of 3DUS and its importance in the pathology compression by parents.

  3. GRADE Equity Guidelines 3

    DEFF Research Database (Denmark)

    Welch, Vivian A; Akl, Elie A; Pottie, Kevin

    2017-01-01

    OBJECTIVE: The aim of this paper is to describe a conceptual framework for how to consider health equity in the GRADE (Grading Recommendations Assessment and Development Evidence) guideline development process. STUDY DESIGN AND SETTING: Consensus-based guidance developed by the GRADE working grou...

  4. Stereotactic radiotherapy of meningiomas compressing optical pathways

    International Nuclear Information System (INIS)

    Hamm, Klaus-Detlef; Henzel, Martin; Gross, Markus W.; Surber, Gunnar; Kleinert, Gabriele; Engenhart-Cabillic, Rita

    2006-01-01

    Purpose: Microsurgical resection is usually the treatment of choice for meningiomas, especially for those that compress the optical pathways. However, in many cases of skull-base meningiomas a high risk of neurological deficits and recurrences exist in cases where the complete tumor removal was not possible. In such cases (fractionated) stereotactic radiotherapy (SRT) can offer an alternative treatment option. We evaluated the local control rate, symptomatology, and toxicity. Patients and Methods: Between 1997 and 2003, 183 patients with skull-base meningiomas were treated with SRT, among them were 65 patients with meningiomas that compressed optical pathways (64 benign, 1 atypical). Of these 65 cases, 20 were treated with SRT only, 27 were subtotally resected before SRT, and 18 underwent multiple tumor resections before SRT. We investigated the results until 2005, with a median follow-up of 45 months (range, 22-83 months). The tumor volume (TV = gross tumor volume) ranged from 0.61 to 90.20 cc (mean, 18.9 cc). Because of the risk of new visual disturbances, the dose per fraction was either 2 or 1.8 Gy for all patients, to a total dose of 50 to 60 Gy. Results: The overall survival and the progression-free survival rates for 5 years were assessed to 100% in this patient group. To date, no progression for these meningiomas have been observed. Quantitatively, tumor shrinkage of more than 20%, or more than 2 mm in diameter, was proved in 35 of the 65 cases after SRT. In 29 of the 65 patients, at least 1 of the symptoms improved. On application of the Common Toxicity Criteria (CTC), acute toxicity (Grade 3) was seen in 1 case (worsening of conjunctivitis). Another 2 patients developed late toxicity by LENT-SOMA score, 1 x Grade 1 and 1 x Grade 3 (field of vision loss). Conclusion: As a low-risk and effective treatment option for tumor control, SRT with 1.8 to 2.0 Gy per fraction can also be recommended in case of meningiomas that compress optical pathways. An

  5. Colorectal injury by compressed air--a report of 2 cases.

    Science.gov (United States)

    Suh, H. H.; Kim, Y. J.; Kim, S. K.

    1996-01-01

    We report two colorectal trauma patients whose rectosigmoid region was ruptured due to a jet of compressed air directed to their anus while they were playing practical jokes with their colleagues in their place of work. It was difficult to diagnose in one patient due to vague symptoms and signs and due to being stunned by a stroke of the compressed air. Both patients suffered from abdominal pain and distension, tension pneumoperitoneum and mild respiratory alkalosis. One patient was treated with primary two layer closure, and the other with primary two layer closure and sigmoid loop colostomy. Anorectal manometry and transanal ultrasonography checked 4 weeks after surgery, revealed normal anorectal function and anatomy. The postoperative courses were favorable without any wound infection or intraabdominal sepsis. PMID:8835767

  6. Introduction to compressible fluid flow

    CERN Document Server

    Oosthuizen, Patrick H

    2013-01-01

    IntroductionThe Equations of Steady One-Dimensional Compressible FlowSome Fundamental Aspects of Compressible FlowOne-Dimensional Isentropic FlowNormal Shock WavesOblique Shock WavesExpansion Waves - Prandtl-Meyer FlowVariable Area FlowsAdiabatic Flow with FrictionFlow with Heat TransferLinearized Analysis of Two-Dimensional Compressible FlowsHypersonic and High-Temperature FlowsHigh-Temperature Gas EffectsLow-Density FlowsBibliographyAppendices

  7. Mammographic compression in Asian women.

    Science.gov (United States)

    Lau, Susie; Abdul Aziz, Yang Faridah; Ng, Kwan Hoong

    2017-01-01

    To investigate: (1) the variability of mammographic compression parameters amongst Asian women; and (2) the effects of reducing compression force on image quality and mean glandular dose (MGD) in Asian women based on phantom study. We retrospectively collected 15818 raw digital mammograms from 3772 Asian women aged 35-80 years who underwent screening or diagnostic mammography between Jan 2012 and Dec 2014 at our center. The mammograms were processed using a volumetric breast density (VBD) measurement software (Volpara) to assess compression force, compression pressure, compressed breast thickness (CBT), breast volume, VBD and MGD against breast contact area. The effects of reducing compression force on image quality and MGD were also evaluated based on measurement obtained from 105 Asian women, as well as using the RMI156 Mammographic Accreditation Phantom and polymethyl methacrylate (PMMA) slabs. Compression force, compression pressure, CBT, breast volume, VBD and MGD correlated significantly with breast contact area (pAsian women. The median compression force should be about 8.1 daN compared to the current 12.0 daN. Decreasing compression force from 12.0 daN to 9.0 daN increased CBT by 3.3±1.4 mm, MGD by 6.2-11.0%, and caused no significant effects on image quality (p>0.05). Force-standardized protocol led to widely variable compression parameters in Asian women. Based on phantom study, it is feasible to reduce compression force up to 32.5% with minimal effects on image quality and MGD.

  8. Correlation of MR tomographic findings and microvascular decompression treatment of the neurovascular compressions of the cranial nerves

    International Nuclear Information System (INIS)

    Liu Zengsheng; Chen Xiangmin; Sun Yiyan; Fang Ming; Wang Ping; Guan Yong; Sun Miao

    2010-01-01

    Objective: To explore the correlation of the operation effects of the miorovascular decompression (MVD) and the findings on magnetic resonance tomographie angiography (MRTA) in patients of neurovascular compression of the cranial nerves. Methods: Two hundred and twenty three patients treated with the microvascular decompression were analyzed retrospectively. They were grouped and graded according to the vessel compression on the cranial nerves. The compression were grouped as none, moderate and severe, and the operation effects were graded as I (complete relief), II (partial relief) and III ( no relief). The operation effects grades were correlated according to the compression groups by Kruskal-Wallis test and the operation effects between each two of the groups were compared using Nemenyi test. P 2 =16.84 and P<0.05. The mean rank of the non-compression, the moderate and the severe group was 134.21,102.37 and 110.4, respectively. The difference of the mean ranks between the non-compression group and the moderate group was 31.84, and between the non-compression and the severe group was 24.17, respectively, where P<0.05 both. Conclusions: There was close relationship between the findings on magnetic resonance tomographic angiography and the operation effects of the MVD. The operation effects of patients with moderate and severe vessel compression were much better than the non-compression group. MRTA is helpful for MVD surgical indication and its prognosis. (authors)

  9. Spinal meningioma: relationship between degree of cord compression and outcome.

    Science.gov (United States)

    Davies, Simon; Gregson, Barbara; Mitchell, Patrick

    2017-04-01

    The aim of this study was to find the relationships between the degree of cord compression as seen on MRIs with persisting cord atrophy after decompression and patient outcomes in spinal meningiomas. We undertook a retrospective analysis of 31 patients' pre- and postoperative MRIs, preoperative functional status and their outcomes at follow-up. The following metrics were analysed; percentage cord area at maximum compression, percentage tumour occupancy and percentage cord occupancy. These were then compared with outcome as measured by the Nurick scale. Of the 31 patients, 27 (87%) had thoracic meningiomas, 3 (10%) cervical and 1 (3%) cervicothoracic. The meningiomas were pathologically classified as grade 1 (29) or grade 2 (2) according to the WHO classification. The average remaining cord cross-sectional area was 61% of the estimated original value. The average tumour occupancy of the canal was 72%. The average cord occupancy of the spinal canal at maximum compression was 20%. No correlation between cord cross-section area and Nurick Scale was seen. On the postoperative scan, the average cord area had increased to 84%. No correlation was seen between this value and outcome. We found that cross-section area measurements on MRI scans have no obvious relationship with function before or after surgery. This is a base for future research into the mechanism of cord recovery and other compressive cord conditions.

  10. Characterization of particle deformation during compression measured by confocal laser scanning microscopy.

    Science.gov (United States)

    Guo, H X; Heinämäki, J; Yliruusi, J

    1999-09-20

    Direct compression of riboflavin sodium phosphate tablets was studied by confocal laser scanning microscopy (CLSM). The technique is non-invasive and generates three-dimensional (3D) images. Tablets of 1% riboflavin sodium phosphate with two grades of microcrystalline cellulose (MCC) were individually compressed at compression forces of 1.0 and 26.8 kN. The behaviour and deformation of drug particles on the upper and lower surfaces of the tablets were studied under compression forces. Even at the lower compression force, distinct recrystallized areas in the riboflavin sodium phosphate particles were observed in both Avicel PH-101 and Avicel PH-102 tablets. At the higher compression force, the recrystallization of riboflavin sodium phosphate was more extensive on the upper surface of the Avicel PH-102 tablet than the Avicel PH-101 tablet. The plastic deformation properties of both MCC grades reduced the fragmentation of riboflavin sodium phosphate particles. When compressed with MCC, riboflavin sodium phosphate behaved as a plastic material. The riboflavin sodium phosphate particles were more tightly bound on the upper surface of the tablet than on the lower surface, and this could also be clearly distinguished by CLSM. Drug deformation could not be visualized by other techniques. Confocal laser scanning microscopy provides valuable information on the internal mechanisms of direct compression of tablets.

  11. Ultrasonography - A diagnostic modality for oral and maxillofacial diseases

    Directory of Open Access Journals (Sweden)

    Priya Shirish Joshi

    2014-01-01

    Full Text Available Background: Many diseases present themselves in oral and maxillofacial regions and various modalities may be applied for their diagnosis, including intraoral and panoramic radiography, ultrasonography (USG, computer tomography, magnetic resonance imaging, and nuclear medicine methods such as positron emission tomography. Of these modalities, USG is easy to-use for the detection of non-invasive and soft tissue related diseases in oral and maxillofacial regions. USG plays an important role in analyzing normal and abnormal structures. In particular, in oral and maxillofacial regions, the USG may be clinically applied to evaluate lymph nodes, subcutaneous, and oral cavity-related diseases. Aims: The aim was to correlate the findings of USG and histopathology for the diagnosis of oral and maxillofacial pathology and to evaluate whether USG can be used as an adjunct in diagnosing oral and maxillofacial pathology. Materials and Methods: A total of 10 clinically diagnosed patients with intraoral cancerous growths, swellings in maxillary and neck region were included in this study. Incision biopsy was obtained for confirming provisional clinical diagnosis. The selected cases were advised USG. All patients were then posted either for hemi-glossectomy, hemi-mandibulectomy, and partial maxillectomy with or without radical neck dissection. Statistical Analysis: Student′s t-test and coefficient of correlation was used to statistically analyze significant relationship of both the methods. Result: In all 10 cases, USG correlated well with histopathology findings, it could also delineate tumor extent and measure tumor thickness. Conclusion: USG is an excellent method for the diagnosis of soft tissue lesions and can be used as an adjunct in diagnosing oral and maxillofacial pathology.

  12. Does Prebiopsy, Nonsterile Ultrasonography Gel Affect Biopsy-Site Asepsis?

    International Nuclear Information System (INIS)

    Gurel, Kamil; Karabay, Oguz; Gurel, Safiye; Hildebolt, Charles

    2008-01-01

    Purpose. The purpose of this study was to determine the extent to which the use of nonsterile gel, prior to antiseptic procedures in ultrasonography (US)-guided percutaneous biopsies, results in contamination of the biopsy site. Materials and Methods. Patients referred for US-guided percutaneous biopsies were included in this study. Transmission material used for US evaluation before biopsy-site antiseptic procedures were performed was either nonsterile gel or sterile saline. Patients were randomly assigned to two groups: nonsterile gel (n = 30) and sterile saline (n = 30). Before the transmission material was used and after antiseptic procedures were performed, microbial swabs of a 10-cm 2 -diameter area were obtained at the biopsy site. Swabs were also obtained from the gel, saline, and povidine-iodine. Inoculated specimen plates were incubated at 37 o C under aerobic conditions, and the numbers of colony-forming units recorded. Nominal logistic regression analysis was used to calculate the odds of postantisepsis bacterial growth (after antiseptic procedures were performed) based on group, gender, coincidental disease (diabetes, chronic renal failure, and malignancy), biopsy-site location (head and neck or breast and abdomen), and local factors (skin fold, skin tag, and hair). Results. The following odds ratios (adjusted for the other variables) and their 95% confidence intervals were calculated: (1) group (2.9 [0.8-11.1]; p = 0.10); (2) gender (1.2 [0.3-5.2]; p = 0.78); (3) coincidental disease (7.6 [0.9-166.7]; p = 0.09); (4) biopsy site location (6.2 [1.4-31.3]; p = 0.02); and (5) local factors (7.0 [1.6-36.0]; p = 0.01). No bacterial growth occurred with swabs obtained from gel, povidine-iodine, or saline. Conclusion. We conclude that nonsterile gel used prior to percutaneous biopsy does not affect biopsy-site asepsis

  13. Evaluation of real time ultrasonography of the normal pancreas

    International Nuclear Information System (INIS)

    Kim, H. K.; Ko, Y. T.; Kim, S. Y.; Ahn, C. Y.

    1981-01-01

    91 cases who were free of pancreatic disease and the related conditions, were studied by high resolution and wide field real time ultrasonographic scanner with 3.5 MHz linear array electronically focusing transducers. The pancreatic examination method and the anatomic structures in and around the pancreas were investigated, and the normal pancreatic findings by real time ultrasonography were as follows: 1. Among all 91 cases, 44 cases were male and 47 cases female, and the frequent age groups were the 4th to the sixth decade. 2. The pancreatic images were obtained in 86% and the good images in 65%. 3. The shapes of pancreas were sausage (40%), dumb-bell (34%), tadpole (9%), and club (17%). 4. Pancreatic size was 1.56 ± 0.37, 2.4, 0.8 cm (Mean ± SD, Max., Min.) in head, 1.32 ± 0.29, 2.0, 0.8 cm in isthmus, and 1.62 ± 0.31, 2.4, 1.0 cm in tail. 5. The successful rate of pancreatic duct visualization was 46%. The shapes of pancreatic duct were linear (22%), tramline (16%), and tubular (8%). 6. The pancreatic echogenecity is greater than that of the liver in 68%, and equivalent to that of the liver in 32%, and no normal pancreas displayed less echogenecity than the liver. 7. Pancreatic echogenecity is lesser than that of adjacent soft tissue in 79% and equivalent to that of adjacent soft tissue in 21%. 8. The pancreatic echogenecity is homogenous in 79%. 9. The pancreatic margin is smooth in 62%, undulated in 11%, and ill defined in 27%

  14. Quantitative Assessment of Hepatic Fibrosis by Contrast-enhanced Ultrasonography

    Institute of Scientific and Technical Information of China (English)

    Ming-bo Zhang; En-ze Qu; Ji-Bin Liu; Jin-rui Wang

    2011-01-01

    Objective To explore the contrast-enhanced ultrasonographic features for quantitative assessment of hepatic fibrosis.Methods 86 patients with chronic viral hepatitis B were enrolled in this study from March 2007 to August 2009.The patients were classified into 5 groups (S0-S4) according to fibrosis stage evaluated with ultrasound guided liver biopsy.New contrast-enhanced ultrasonography (CEUS) features including area under the time-intensity curve (TIC) of portal venous phase/hepatic arterial phase (Qp/Qa) and intensity of portal venons phase/hepatic arterial phase (Ip/Ia) were used to detect the blood supply ratio (portal vein/hepatic artery) in each group.Arrival time of portal vein trunk (Tp) and decreasing rate of TIC (β) were also analyzed.Results Qp/Qa and Ip/Ia decreased from So to S4,while Tp and β increased These 4 features were significantly correlated with the degree of fibrosis (P<0.001) and were significantly different among the five groups (P<0.001).Sensitivity and specificity of Ip/Ia were 80% and 86% for groups ≥S1,75% and 86% for groups ≥ S2,71% and 84% for groups ≥ S3,and 76% and 80% for group S4,respectively.Sensitivity and specificity of Qp/Qa were 70% and 88% for groups ≥ S1,80% and 76% for groups ≥ S2,74% and 70% for groups ≥ S3,and 81% and 95% for group S4,respectively.Conclusion Ip/Ia and Qp/Qa could be adopted as reliable,non-invasive features for quantitative assessment of hepatic fibrosis.

  15. Evaluation of peripheral enthesitis in spondyloarthritis: Ultrasonography versus clinical examination

    Directory of Open Access Journals (Sweden)

    Anupam Wakhlu

    2017-01-01

    Full Text Available Background: Enthesitis is an important feature of spondyloarthritis but may often be subclinical. Data is sparse, especially from India, on the ultrasonography (USG detection of enthesitis in these patients. The present study aimed to find the prevalence and pattern of entheseal involvement assessed clinically and by USG. Methods: Fifty-two spondyloarthritis, 26 rheumatoid arthritis, and 26 healthy controls were evaluated for enthesitis by clinical examination and by USG using 2014 OMERACT consensus group definitions at bilateral Achilles insertion on the calcaneus, plantar fascia attachment on the calcaneus, quadriceps tendon insertion on the patella, patellar tendon origin from the inferior pole of the patella, and patellar tendon insertion on the tibial tuberosity. At least one ultrasonographic finding at any of the above sites was considered positive for enthesitis. Results: The number of entheseal sites screened in spondyloarthritis patients was 520 and 260 each in rheumatoid arthritis and healthy controls. USG (sensitivity - 94.2% was better in detecting enthesitis than clinical examination (sensitivity - 69.2%. Clinical examination was highly specific (100% compared to USG (55.7% in differentiating from rheumatoid arthritis and healthy controls. USG alone without clinical findings was positive at 23.8% of sites while clinical examination alone without USG findings was positive at 5.2% of sites. Frequency of enthesitis in rheumatoid arthritis was not more than healthy controls (6.1% vs. 8.1%, respectively and was much less than spondyloarthritis (34%. Conclusion: USG is a good screening tool for detection of enthesitis but cannot replace clinical examination completely.

  16. Incidence of bacteremia in cirrhotic patients undergoing upper endoscopic ultrasonography.

    Science.gov (United States)

    Fernández-Esparrach, Gloria; Sendino, Oriol; Araujo, Isis; Pellisé, Maria; Almela, Manel; González-Suárez, Begoña; López-Cerón, María; Córdova, Henry; Sanabria, Erwin; Uchima, Hugo; Llach, Josep; Ginès, Àngels

    2014-01-01

    The incidence of bacteremia after endoscopic ultrasonography (EUS) or EUS-guided fine-needle aspiration (EUS-FNA) is between 0% and 4%, but there are no data on this topic in cirrhotic patients. To prospectively assess the incidence of bacteremia in cirrhotic patients undergoing EUS and EUS-FNA. We enrolled 41 cirrhotic patients. Of these, 16 (39%) also underwent EUS-FNA. Blood cultures were obtained before and at 5 and 30 min after the procedure. When EUS-FNA was used, an extra blood culture was obtained after the conclusion of radial EUS and before the introduction of the sectorial echoendoscope. All patients were clinically followed up for 7 days for signs of infection. Blood cultures were positive in 16 patients. In 10 patients, blood cultures grew coagulase-negative Staphylococcus, Corynebacterium species, Propionibacterium species or Acinetobacterium Lwoffii, which were considered contaminants (contamination rate 9.8%, 95% CI: 5.7-16%). The remaining 6 patients had true positive blood cultures and were considered to have had true bacteremia (15%, 95% CI: 4-26%). Blood cultures were positive after diagnostic EUS in five patients but were positive after EUS-FNA in only one patient. Thus, the frequency of bacteremia after EUS and EUS-FNA was 12% and 6%, respectively (95% CI: 2-22% and 0.2-30%, respectively). Only one of the patients who developed bacteremia after EUS had a self-limiting fever with no other signs of infection. Asymptomatic Gram-positive bacteremia developed in cirrhotic patients after EUS and EUS-FNA at a rate higher than in non-cirrhotic patients. However, this finding was not associated with any clinically significant infections. Copyright © 2013 Elsevier España, S.L. and AEEH y AEG. All rights reserved.

  17. Accuracy of endoscopic ultrasonography for diagnosing ulcerative early gastric cancers

    Science.gov (United States)

    Park, Jin-Seok; Kim, Hyungkil; Bang, Byongwook; Kwon, Kyesook; Shin, Youngwoon

    2016-01-01

    Abstract Although endoscopic ultrasonography (EUS) is the first-choice imaging modality for predicting the invasion depth of early gastric cancer (EGC), the prediction accuracy of EUS is significantly decreased when EGC is combined with ulceration. The aim of present study was to compare the accuracy of EUS and conventional endoscopy (CE) for determining the depth of EGC. In addition, the various clinic-pathologic factors affecting the diagnostic accuracy of EUS, with a particular focus on endoscopic ulcer shapes, were evaluated. We retrospectively reviewed data from 236 consecutive patients with ulcerative EGC. All patients underwent EUS for estimating tumor invasion depth, followed by either curative surgery or endoscopic treatment. The diagnostic accuracy of EUS and CE was evaluated by comparing the final histologic result of resected specimen. The correlation between accuracy of EUS and characteristics of EGC (tumor size, histology, location in stomach, tumor invasion depth, and endoscopic ulcer shapes) was analyzed. Endoscopic ulcer shapes were classified into 3 groups: definite ulcer, superficial ulcer, and ill-defined ulcer. The overall accuracy of EUS and CE for predicting the invasion depth in ulcerative EGC was 68.6% and 55.5%, respectively. Of the 236 patients, 36 patients were classified as definite ulcers, 98 were superficial ulcers, and 102 were ill-defined ulcers, In univariate analysis, EUS accuracy was associated with invasion depth (P = 0.023), tumor size (P = 0.034), and endoscopic ulcer shapes (P = 0.001). In multivariate analysis, there is a significant association between superficial ulcer in CE and EUS accuracy (odds ratio: 2.977; 95% confidence interval: 1.255–7.064; P = 0.013). The accuracy of EUS for determining tumor invasion depth in ulcerative EGC was superior to that of CE. In addition, ulcer shape was an important factor that affected EUS accuracy. PMID:27472672

  18. Prediction of cerebrovascular reserve by the MRI and doppler ultrasonography

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Hui Joong; Kim, Yong Sun [Kyungpook National University Hospital, Daegu (Korea, Republic of)

    2005-07-15

    We investigated acute stroke patterns on diffusion weighted images and with doppler ultrasonography studies of ICA and MCA steno-occlusive diseases in order to predict the cerbrovascular reserve (CVR), as was measured by acetazolamide (ACZ)-challenged Tc-99m ECD brain perfusion SPECT. A retrospective analysis was performed of 76 patients who underwent MRI/MRA, ACZ-challenged Tc-99m ECD brain perfusion SPECT, and carotid and vertebral artery Doppler sonography. After dividing these patients into four groups-MCA and ICA ateno-occlusions, we analyzed the relationship between the CVR and topologic MR patterns and the flow volume, as was measured by Doppler sonography. The CVRs were preserved in 26 of 76 patients. The CVRs were impaired in those cases of occlusion that were detected on MRA and also by the pattern of the territorial involvement on the diffusion weighted image ({rho} < 0.05, x{sup 2} test). Yet in cases of preserved CVRs, the flow volume of the contralateral ICA, the anterior circulation, and the total cerebral flow volume were increased, as was checked by Doppler sonography ({rho} < 0.05, t-test). As calculated by logistic regression analysis, the accuracy for predicting the preserved CVR by using the statistically significant variables was 78%. We believe that the MRI-SPECT correlation study was helpful for understanding the hemodynamics and topographic patterns of ischemia in patients with ICA and MCA steno-occlusive disease, and that the flow volume measurement, which was done by using duplex US, was useful for predicting the CVR.

  19. Adiabatic compression and radiative compression of magnetic fields

    International Nuclear Information System (INIS)

    Woods, C.H.

    1980-01-01

    Flux is conserved during mechanical compression of magnetic fields for both nonrelativistic and relativistic compressors. However, the relativistic compressor generates radiation, which can carry up to twice the energy content of the magnetic field compressed adiabatically. The radiation may be either confined or allowed to escape

  20. Comparison of the capsular width measured on ultrasonography and MR image of the temporomandibular joint

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Tae Wan; Yoo, Dong Soo; Han, Won Jeong; Kim, Eun Kyung [Dankook University, Seoul (Korea, Republic of)

    2006-03-15

    To evaluate the reliability and clinical usefulness of ultrasonography in the temporomandibular joint(TMJ). Parasagittal and paracoronal 1.5 T MR images and 7.5 MHz ultrasonography of 40 TMJs in 20 asymptomatic volunteers were obtained. Disc position using MR imaging was evaluated and the distance between the lateral surface of mandibular condyle and the articular capsule using MR image and ultrasonography of 27 TMJs with normal disc position was measured and compared. Intraobserver and interobserver measurements reliability was evaluated by using interclass correlation coefficients (ICC) and measurement error. Also, the distance measured on ultrasonography was compared, according to mouth position and disc position. The normal disc position was found in 27 of 40 asymptomatic joints. At the intraobserver reliability of measurement, ICC at the closed and open mouth position were 0.89 and 0.91. The measurement error was 0.4% and 0.5%. At the interobserver reliability, ICC at the closed and open mouth position, the distances between the lateral surface of mandibular condyle and the articular capsule measured on MR images and ultrasonography were 2.0{+-} 0.7 mm, 1.8{+-}0.5 mm, respectively (p<0.05). On the ultrasonography, the distances at open mouth position were 1.2{+-}0.5 mm (p<0.05). At the TMJ with medially displaced disc, the distances at the closed and open mouth position were 1.3{+-}0.3 mm and 0.9{+-}0.2 mm (p<0.05). The results suggest ultrasonography of TMJ is a reliable imaging technique for assessment of normal disc position.

  1. Reliability of Ultrasonography in Confirming Endotracheal Tube Placement in an Emergency Setting

    Science.gov (United States)

    Thomas, Vimal Koshy; Paul, Cherish; Rajeev, Punchalil Chathappan; Palatty, Babu Urumese

    2017-01-01

    Background and Objectives: Over the past few years, ultrasonography is increasingly being used to confirm the correct placement of endotracheal tube (ETT). In our study, we aimed to compare it with the traditional clinical methods and the gold standard quantitative waveform capnography. Two primary outcomes were measured in our study. First was the sensitivity and specificity of ultrasonography against the other two methods to confirm endotracheal intubation. The second primary outcome assessed was the time taken for each method to confirm tube placement in an emergency setting. Methods: This is a single-centered, prospective cohort study conducted in an emergency department of a tertiary care hospital. We included 100 patients with indication of emergency intubation by convenient sampling. The intubation was performed as per standard hospital protocol. As part of the study protocol, ultrasonography was used to identify ETT placement simultaneously with the intubation procedure along with quantitative waveform capnography (end-tidal carbon dioxide) and clinical methods. Confirmation of tube placement and time taken for the same were noted by three separate health-care staffs. Results and Discussion: Out of the 100 intubation attempts, five (5%) had esophageal intubations. The sensitivity and specificity of diagnosis using ultrasonography were 97.89% and 100%, respectively. This was statistically comparable with the other two modalities. The time taken to confirm tube placement with ultrasonography was 8.27 ± 1.54 s compared to waveform capnography and clinical methods which were 18.06 ± 2.58 and 20.72 ± 3.21 s, respectively. The time taken by ultrasonography was significantly less. Conclusions: Ultrasonography confirmed tube placement with comparable sensitivity and specificity to quantitative waveform capnography and clinical methods. But then, it yielded results considerably faster than the other two modalities. PMID:28584427

  2. Bedside Ultrasonography versus Brain Natriuretic Peptide in Detecting Cardiogenic Causes of Acute Dyspnea

    Directory of Open Access Journals (Sweden)

    Keihan Golshani

    2016-04-01

    Full Text Available Acute dyspnea is a common cause of hospitalization in emergency departments (ED.Distinguishing the cardiac causes of acute dyspnea from pulmonary ones is a major challenge for responsible physicians in EDs. This study compares the characteristics of bedside ultrasonography with serum level of blood natriuretic peptide (BNP in this regard. Methods: This diagnostic accuracy study compares bedside ultrasonography with serum BNP levels in differentiating cardiogenic causes of acute respiratory distress. Echocardiography was considered as the reference test. A checklist including demographic data (age and sex, vital signs, medical history, underlying diseases, serum level of BNP, as well as findings of chest radiography, chest ultrasonography, and echocardiography was filled for all patients with acute onset of dyspnea. Screening characteristics of the two studied methods were calculated and compared using SPSS software, version 20. Results: 48 patients with acute respiratory distress were evaluated (50% female. The mean age of participants was 66.94 ± 16.33 (28-94 years. Based on the results of echocardiography and final diagnosis, the cause of dyspnea was cardiogenic in 20 (41.6% cases. Bedside ultrasonography revealed the cardiogenic cause of acute dyspnea in 18 cases (0 false positive and BNP in 44 cases (24 false positives. The area under the ROC curve for bedside ultrasonography and BNP for differentiating the cardiogenic cause of dyspnea were 86.4 (95% CI: 74.6-98.3 and 66.3 (95% CI: 49.8-89.2, respectively (p = 0.0021. Conclusion: It seems that bedside ultrasonography could be considered as a helpful and accurate method in differentiating cardiogenic causes of acute dyspnea in emergency settings. Nevertheless, more study is needed to make a runaway algorithm to evaluate patients with respiratory distress using bedside ultrasonography, which leads to rapid therapeutic decisions in a short time.

  3. The Efficacy of Thoracic Ultrasonography in Postoperative Newborn Patients after Cardiac Surgery

    Directory of Open Access Journals (Sweden)

    Erkut Ozturk

    Full Text Available Abstract Objective: In this study, the efficacy of thoracic ultrasonography during echocardiography was evaluated in newborns. Methods: Sixty newborns who had undergone pediatric cardiac surgery were successively evaluated between March 1, 2015, and September 1, 2015. Patients were evaluated for effusion, pulmonary atelectasis, and pneumothorax by ultrasonography, and results were compared with X-ray findings. Results: Sixty percent (n=42 of the cases were male, the median age was 14 days (2-30 days, and the median body weight was 3.3 kg (2.8-4.5 kg. The median RACHS-1 score was 4 (2-6. Atelectasis was demonstrated in 66% (n=40 of the cases. Five of them were determined solely by X-ray, 10 of them only by ultrasonography, and 25 of them by both ultrasonography and X-ray. Pneumothorax was determined in 20% (n=12 of the cases. Excluding one case determined by both methods, all of the 11 cases were diagnosed by X-ray. Pleural effusion was diagnosed in 26% (n=16 of the cases. Four of the cases were demonstrated solely by ultrasonography, three of them solely by X-ray, and nine of the cases by both methods. Pericardial effusion was demonstrated in 10% (n=6 of the cases. Except for one of the cases determined by both methods, five of the cases were diagnosed by ultrasonography. There was a moderate correlation when all pathologies evaluated together (k=0.51. Conclusion: Thoracic ultrasonography might be a beneficial non-invasive method to evaluate postoperative respiratory problems in newborns who had congenital cardiac surgery.

  4. Graded gauge theory

    International Nuclear Information System (INIS)

    Kerner, R.

    1983-01-01

    The mathematical background for a graded extension of gauge theories is investigated. After discussing the general properties of graded Lie algebras and what may serve as a model for a graded Lie group, the graded fiber bundle is constructed. Its basis manifold is supposed to be the so-called superspace, i.e. the product of the Minkowskian space-time with the Grassmann algebra spanned by the anticommuting Lorentz spinors; the vertical subspaces tangent to the fibers are isomorphic with the graded extension of the SU(N) Lie algebra. The connection and curvature are defined then on this bundle; the two different gradings are either independent of each other, or may be unified in one common grading, which is equivalent to the choice of the spin-statistics dependence. The Yang-Mills lagrangian is investigated in the simplified case. The conformal symmetry breaking is discussed, as well as some other physical consequences of the model. (orig.)

  5. Waves and compressible flow

    CERN Document Server

    Ockendon, Hilary

    2016-01-01

    Now in its second edition, this book continues to give readers a broad mathematical basis for modelling and understanding the wide range of wave phenomena encountered in modern applications.  New and expanded material includes topics such as elastoplastic waves and waves in plasmas, as well as new exercises.  Comprehensive collections of models are used to illustrate the underpinning mathematical methodologies, which include the basic ideas of the relevant partial differential equations, characteristics, ray theory, asymptotic analysis, dispersion, shock waves, and weak solutions. Although the main focus is on compressible fluid flow, the authors show how intimately gasdynamic waves are related to wave phenomena in many other areas of physical science.   Special emphasis is placed on the development of physical intuition to supplement and reinforce analytical thinking. Each chapter includes a complete set of carefully prepared exercises, making this a suitable textbook for students in applied mathematics, ...

  6. Detection of rib fractures in minor chest injuries: a comparison between ultrasonography and radiography performed on the same day

    Energy Technology Data Exchange (ETDEWEB)

    Cho, Yong Soo; Back, Chang Hee; Lee, Kyung Rae; Shin, Yun Hack; Whang, Yeong Seop; Jeong, Ku Young [Yeosu Baek Hospital, Yeosu (Korea, Republic of); Chung, Soo Hyun [NamWon Medical Center, NamWon (Korea, Republic of); Whang, Cheol Mog [Konyang University Hospital, Daejeon (Korea, Republic of)

    2007-04-15

    We wished to compare the ability of ultrasonography and radiography performed on the same day to detect rib fractures in minor chest injuries. Two hundred and fifteen patients with minor chest injuries were selected. Radiography and ultrasonography were performed on the same day with these patients. Chest wall pain was the only presenting symptom. Two radiologists performed ultrasonography. Fractures were identified by a disruption of the anterior margin of the rib and costal cartilage. The incidence and location of fractures and complications revealed by radiography and ultrasonography were compared. Radiographs revealed the presence of 70 rib fractures in 50 (23%) of 215 patients and ultrasonography revealed the presence of 203 rib fractures in 133 (62%) of 215 patients. Ultrasonography uniquely identified 133 rib fractures in 83 patients. Ultrasonography identified a 2.9 fold increase in the number of fractures in a 2.6 fold number of subjects as compared to radiography. Of the 203 sonographically detected fractures, 201 were located in the rib, one was located at the costochondral junction, and one in the costal cartilage. There were no complications seen by either radiography or ultrasonography. Ultrasonography reveals more fractures than those that may be overlooked on radiography for minor chest injuries.

  7. Detection of rib fractures in minor chest injuries: a comparison between ultrasonography and radiography performed on the same day

    International Nuclear Information System (INIS)

    Cho, Yong Soo; Back, Chang Hee; Lee, Kyung Rae; Shin, Yun Hack; Whang, Yeong Seop; Jeong, Ku Young; Chung, Soo Hyun; Whang, Cheol Mog

    2007-01-01

    We wished to compare the ability of ultrasonography and radiography performed on the same day to detect rib fractures in minor chest injuries. Two hundred and fifteen patients with minor chest injuries were selected. Radiography and ultrasonography were performed on the same day with these patients. Chest wall pain was the only presenting symptom. Two radiologists performed ultrasonography. Fractures were identified by a disruption of the anterior margin of the rib and costal cartilage. The incidence and location of fractures and complications revealed by radiography and ultrasonography were compared. Radiographs revealed the presence of 70 rib fractures in 50 (23%) of 215 patients and ultrasonography revealed the presence of 203 rib fractures in 133 (62%) of 215 patients. Ultrasonography uniquely identified 133 rib fractures in 83 patients. Ultrasonography identified a 2.9 fold increase in the number of fractures in a 2.6 fold number of subjects as compared to radiography. Of the 203 sonographically detected fractures, 201 were located in the rib, one was located at the costochondral junction, and one in the costal cartilage. There were no complications seen by either radiography or ultrasonography. Ultrasonography reveals more fractures than those that may be overlooked on radiography for minor chest injuries

  8. Use of gray-scale ultrasonography in the diagnosis of reproductive disease in the bitch: 18 cases (1981-1984)

    International Nuclear Information System (INIS)

    Poffenbarger, E.M.; Feeney, D.A.

    1986-01-01

    Gray-scale ultrasonography was utilized in addition to radiography in the diagnosis of reproductive disease in 18 bitches. In 72% of the cases, ultrasonography was considered diagnostic because it revealed information on organ architecture, relationships of radiographically silhouetting soft tissue structures, and fetal viability that was unobtainable by radiography alone. In the remainder of the cases, ultrasonography was contributory to the diagnostic process by supporting the clinical and radiographic diagnoses. The benefits of ultrasonography are discussed, as is the ultrasonographic appearance of a variety of reproductive tract diseases

  9. Time of flight measurements of unirradiated and irradiated nuclear graphite under cyclic compressive load

    Energy Technology Data Exchange (ETDEWEB)

    Bodel, W., E-mail: william.bodel@hotmail.com [Nuclear Graphite Research Group, The University of Manchester (United Kingdom); Atkin, C. [Health and Safety Laboratory, Buxton (United Kingdom); Marsden, B.J. [Nuclear Graphite Research Group, The University of Manchester (United Kingdom)

    2017-04-15

    The time-of-flight technique has been used to investigate the stiffness of nuclear graphite with respect to the grade and grain direction. A loading rig was developed to collect time-of-flight measurements during cycled compressive loading up to 80% of the material's compressive strength and subsequent unloading of specimens along the axis of the applied stress. The transmission velocity (related to Young's modulus), decreased with increasing applied stress; and depending on the graphite grade and orientation, the modulus then increased, decreased or remained constant upon unloading. These tests were repeated while observing the microstructure during the load/unload cycles. Initial decreases in transmission velocity with compressive load are attributed to microcrack formation within filler and binder phases. Three distinct types of behaviour occur on unloading, depending on the grade, irradiation, and loading direction. These different behaviours can be explained in terms of the material microstructure observed from the microscopy performed during loading.

  10. Application specific compression : final report.

    Energy Technology Data Exchange (ETDEWEB)

    Melgaard, David Kennett; Byrne, Raymond Harry; Myers, Daniel S.; Harrison, Carol D.; Lee, David S.; Lewis, Phillip J.; Carlson, Jeffrey J.

    2008-12-01

    With the continuing development of more capable data gathering sensors, comes an increased demand on the bandwidth for transmitting larger quantities of data. To help counteract that trend, a study was undertaken to determine appropriate lossy data compression strategies for minimizing their impact on target detection and characterization. The survey of current compression techniques led us to the conclusion that wavelet compression was well suited for this purpose. Wavelet analysis essentially applies a low-pass and high-pass filter to the data, converting the data into the related coefficients that maintain spatial information as well as frequency information. Wavelet compression is achieved by zeroing the coefficients that pertain to the noise in the signal, i.e. the high frequency, low amplitude portion. This approach is well suited for our goal because it reduces the noise in the signal with only minimal impact on the larger, lower frequency target signatures. The resulting coefficients can then be encoded using lossless techniques with higher compression levels because of the lower entropy and significant number of zeros. No significant signal degradation or difficulties in target characterization or detection were observed or measured when wavelet compression was applied to simulated and real data, even when over 80% of the coefficients were zeroed. While the exact level of compression will be data set dependent, for the data sets we studied, compression factors over 10 were found to be satisfactory where conventional lossless techniques achieved levels of less than 3.

  11. Compressed Baryonic Matter of Astrophysics

    OpenAIRE

    Guo, Yanjun; Xu, Renxin

    2013-01-01

    Baryonic matter in the core of a massive and evolved star is compressed significantly to form a supra-nuclear object, and compressed baryonic matter (CBM) is then produced after supernova. The state of cold matter at a few nuclear density is pedagogically reviewed, with significant attention paid to a possible quark-cluster state conjectured from an astrophysical point of view.

  12. Streaming Compression of Hexahedral Meshes

    Energy Technology Data Exchange (ETDEWEB)

    Isenburg, M; Courbet, C

    2010-02-03

    We describe a method for streaming compression of hexahedral meshes. Given an interleaved stream of vertices and hexahedral our coder incrementally compresses the mesh in the presented order. Our coder is extremely memory efficient when the input stream documents when vertices are referenced for the last time (i.e. when it contains topological finalization tags). Our coder then continuously releases and reuses data structures that no longer contribute to compressing the remainder of the stream. This means in practice that our coder has only a small fraction of the whole mesh in memory at any time. We can therefore compress very large meshes - even meshes that do not file in memory. Compared to traditional, non-streaming approaches that load the entire mesh and globally reorder it during compression, our algorithm trades a less compact compressed representation for significant gains in speed, memory, and I/O efficiency. For example, on the 456k hexahedra 'blade' mesh, our coder is twice as fast and uses 88 times less memory (only 3.1 MB) with the compressed file increasing about 3% in size. We also present the first scheme for predictive compression of properties associated with hexahedral cells.

  13. Data Compression with Linear Algebra

    OpenAIRE

    Etler, David

    2015-01-01

    A presentation on the applications of linear algebra to image compression. Covers entropy, the discrete cosine transform, thresholding, quantization, and examples of images compressed with DCT. Given in Spring 2015 at Ocean County College as part of the honors program.

  14. Images compression in nuclear medicine

    International Nuclear Information System (INIS)

    Rebelo, M.S.; Furuie, S.S.; Moura, L.

    1992-01-01

    The performance of two methods for images compression in nuclear medicine was evaluated. The LZW precise, and Cosine Transformed, approximate, methods were analyzed. The results were obtained, showing that the utilization of approximated method produced images with an agreeable quality for visual analysis and compression rates, considerably high than precise method. (C.G.C.)

  15. Compressive Sensing in Communication Systems

    DEFF Research Database (Denmark)

    Fyhn, Karsten

    2013-01-01

    . The need for cheaper, smarter and more energy efficient wireless devices is greater now than ever. This thesis addresses this problem and concerns the application of the recently developed sampling theory of compressive sensing in communication systems. Compressive sensing is the merging of signal...... acquisition and compression. It allows for sampling a signal with a rate below the bound dictated by the celebrated Shannon-Nyquist sampling theorem. In some communication systems this necessary minimum sample rate, dictated by the Shannon-Nyquist sampling theorem, is so high it is at the limit of what...... with using compressive sensing in communication systems. The main contribution of this thesis is two-fold: 1) a new compressive sensing hardware structure for spread spectrum signals, which is simpler than the current state-of-the-art, and 2) a range of algorithms for parameter estimation for the class...

  16. Contrast-enhanced ultrasonography depicts small tumor vessels for the evaluation of pancreatic tumors

    International Nuclear Information System (INIS)

    Okamoto, Yuko; Kawamoto, Hirofumi; Takaki, Akinobu; Ishida, Etsuji; Ogawa, Tsuneyoshi; Kuwaki, Kenji; Kobayashi, Yoshiyuki; Sakaguchi, Kohsaku; Shiratori, Yasushi

    2007-01-01

    Objective: The aim of this study is to evaluate the efficacy of contrast-enhanced ultrasonography for the diagnosis of pancreatic tumors. Materials and methods: Contrast-enhanced ultrasonography with Levovist was performed on 62 consecutive patients (53 with pancreatic cancer, 4 with islet cell tumor, 3 with inflammatory pancreatic tumor, and 2 with metastatic tumor). The vascular and perfusion image phases of the tumors were evaluated and compared with the findings of contrast-enhanced computed tomography. Results: Contrast-enhanced ultrasonography showed tumor vessels around and/or in the tumor at the vascular image phase in 79% of pancreatic cancer patients (42/53). At the perfusion image phase, 96% of pancreatic cancers (51/53) were classified as hypo-enhancement type. However, tiny spotty or irregular heterogeneous enhanced lesions were found in 84% of hypo-enhanced pancreatic cancer patients (43/51). The presence of small vessels at the vascular image phase was closely correlated with the presence of these intratumor regional enhanced lesions at the perfusion image phase (κ coefficient = 0.42). The sensitivity of contrast-enhanced ultrasonography (100%) for pancreatic cancer was superior to that of contrast-enhanced computed tomography (91%), but no significant difference was observed between the two (McNemar test: p = 0.063). Conclusion: Contrast-enhanced ultrasonography with Levovist successfully visualizes fine vessels and enhancement in pancreatic tumors, and is useful for evaluating pancreatic tumors

  17. Ultrasonography of symptomatic rotator cuff tears compared with MR imaging and surgery

    International Nuclear Information System (INIS)

    Fotiadou, Anastasia N.; Vlychou, Marianna; Papadopoulos, Periklis; Karataglis, Dimitrios S.; Palladas, Panagiotis; Fezoulidis, Ioannis V.

    2008-01-01

    Purpose: To compare the accuracy of ultrasonography and magnetic resonance imaging in the detection of rotator cuff tears. Materials and methods: Ninety-six patients with clinically suspected rotator cuff pathology underwent ultrasonography and magnetic resonance imaging of the shoulder. The findings in 88 patients were compared with arthroscopy or open surgery. Results: Full-thickness tear was confirmed in 57 cases, partial-thickness tear in 30 cases and degenerative changes without tear in 1. In all 57 cases of full-thickness tear and in 28 out of 30 cases of partial-thickness tear the supraspinatus tendon was involved. The accuracy in the detection of full-thickness tears was 98 and 100% for ultrasonography and magnetic resonance imaging, respectively. The accuracy in the detection of bursal or articular partial-thickness tears was 87 and 90% for ultrasonography and magnetic resonance imaging, respectively. Conclusions: In experienced hands ultrasonography should be considered as an accurate modality for the initial investigation of rotator cuff, especially supraspinatus, tears

  18. Accuracy of ultrasonography and magnetic resonance imaging in the diagnosis of placenta accreta.

    Science.gov (United States)

    Riteau, Anne-Sophie; Tassin, Mikael; Chambon, Guillemette; Le Vaillant, Claudine; de Laveaucoupet, Jocelyne; Quéré, Marie-Pierre; Joubert, Madeleine; Prevot, Sophie; Philippe, Henri-Jean; Benachi, Alexandra

    2014-01-01

    To evaluate the accuracy of ultrasonography and magnetic resonance imaging (MRI) in the diagnosis of placenta accreta and to define the most relevant specific ultrasound and MRI features that may predict placental invasion. This study was approved by the institutional review board of the French College of Obstetricians and Gynecologists. We retrospectively reviewed the medical records of all patients referred for suspected placenta accreta to two university hospitals from 01/2001 to 05/2012. Our study population included 42 pregnant women who had been investigated by both ultrasonography and MRI. Ultrasound images and MRI were blindly reassessed for each case by 2 raters in order to score features that predict abnormal placental invasion. Sensitivity in the diagnosis of placenta accreta was 100% with ultrasound and 76.9% for MRI (P = 0.03). Specificity was 37.5% with ultrasonography and 50% for MRI (P = 0.6). The features of greatest sensitivity on ultrasonography were intraplacental lacunae and loss of the normal retroplacental clear space. Increased vascularization in the uterine serosa-bladder wall interface and vascularization perpendicular to the uterine wall had the best positive predictive value (92%). At MRI, uterine bulging had the best positive predictive value (85%) and its combination with the presence of dark intraplacental bands on T2-weighted images improved the predictive value to 90%. Ultrasound imaging is the mainstay of screening for placenta accreta. MRI appears to be complementary to ultrasonography, especially when there are few ultrasound signs.

  19. Ultrasonography of symptomatic rotator cuff tears compared with MR imaging and surgery

    Energy Technology Data Exchange (ETDEWEB)

    Fotiadou, Anastasia N. [Radiology Department, University Hospital of Larissa, Mezourlo 41110, Larissa (Greece); Radiology Department, G. Papanikolaou Hospital, Exochi 32100, Thessaloniki (Greece)], E-mail: natfot@yahoo.gr; Vlychou, Marianna [Radiology Department, University Hospital of Larissa, Mezourlo 41110, Larissa (Greece)], E-mail: mvlychou@med.uth.gr; Papadopoulos, Periklis [University Orthopaedic Clinic, G. Papanikolaou Hospital, Exochi 32100, Thessaloniki (Greece)], E-mail: perpap@otenet.gr; Karataglis, Dimitrios S. [University Orthopaedic Clinic, G. Papanikolaou Hospital, Exochi 32100, Thessaloniki (Greece)], E-mail: dkarataglis@yahoo.gr; Palladas, Panagiotis [Radiology Department, G. Papanikolaou Hospital, Exochi 32100, Thessaloniki (Greece)], E-mail: palladaspan@in.gr; Fezoulidis, Ioannis V. [Radiology Department, University Hospital of Larissa, Mezourlo 41110, Larissa (Greece)], E-mail: oswestanast@yahoo.gr

    2008-10-15

    Purpose: To compare the accuracy of ultrasonography and magnetic resonance imaging in the detection of rotator cuff tears. Materials and methods: Ninety-six patients with clinically suspected rotator cuff pathology underwent ultrasonography and magnetic resonance imaging of the shoulder. The findings in 88 patients were compared with arthroscopy or open surgery. Results: Full-thickness tear was confirmed in 57 cases, partial-thickness tear in 30 cases and degenerative changes without tear in 1. In all 57 cases of full-thickness tear and in 28 out of 30 cases of partial-thickness tear the supraspinatus tendon was involved. The accuracy in the detection of full-thickness tears was 98 and 100% for ultrasonography and magnetic resonance imaging, respectively. The accuracy in the detection of bursal or articular partial-thickness tears was 87 and 90% for ultrasonography and magnetic resonance imaging, respectively. Conclusions: In experienced hands ultrasonography should be considered as an accurate modality for the initial investigation of rotator cuff, especially supraspinatus, tears.

  20. An experimental comparative study of radiography, ultrasonography and CT imaging in the IV catheter fragment

    International Nuclear Information System (INIS)

    Kweon, Dae Cheol

    2016-01-01

    The objective of this study was to detect the fragments generated during IV (intravenous) catheter injection of contrast medium and drug administration in a clinical setting and removal was performed by experimentally producing a phantom, and to compare the radiography, ultrasonography, and multi-detector computed tomography (MDCT) imaging and radiation dose. A 1 cm fragment of an 18 gage Teflon® IV catheter with saline was inserted into the IV control line. Radiography, CT, and ultrasonography were performed and radiography and CT dose were calculated. CT and ultrasonography showed an IV catheter fragment clinically and radiography showed no visible difference in the ability to provide a useful image of an IV catheter fragment modality (p >.05). Radiography of effective dose (0.2139 mSv·Gy-1·cm-2) form DAP DAP (0.93 μGy·m2 ), and dose length product (DLP) (201 mGy·cm) to effective dose was calculated as 0.483 mSv. IV catheter fragment were detected of radiography, ultrasonography and CT. These results can be obtained by menas of an excellent IV catheter fragment of detection capability CT. However, CT is followed by radiation exposure. IV catheter fragment confirming the position and information recommend an ultrasonography

  1. The diagnostic concordance of endoanal ultrasonography and endoanal MRI in cases of anorectal fistula

    International Nuclear Information System (INIS)

    Kim, Wan Tae; Yoo, Weon Young; Moon, Hee Jung; Shin, Hyun Ja; Joo, Jae Sik

    2000-01-01

    To evaluate the preoperative diagnostic concordance of morphologic classification of anorectal fistula by endoanal ultrasonography (EUSG) and endoanal magnetic resonance imaging (EMRI). Between January 1998 and March 1999, 17 patients with anorectal fistula underwent endoanal ultrasonography and magnetic resonance imaging for preoperative assessment. The types of fistula and abscess formation were evaluated, and the findings compared with those obtained during surgery. The overall accordance of anorectal fistula was 76% (13 of 17 cases) on ultrasonography and 94% (16 of 17 cases) on magnetic resonance imaging. According to the findings of EUSG, the accordance of each type of anorectal fistula was as follows: transphineteric, 92% (11 of 12 cases); suprasphinteric, 33% (1 of 3); and extrasphincteric, 50% (1 of 2), while for EMRI, the respective figures were 100% (12 of 12 cases), 67% (2 of 3), and 100% (2 of 2). An analysis of reproducibility using kappa value showed that overall concordance between endoanal ultrasonography and surgery (κ=0.820) as well as between endoanal MRI and surgery (κ=0.866), was very close. For the evaluation of anorectal fistula, preoperative endoanal magnetic resonance imaging was more accurate and informative than endoanal ultrasonography

  2. The current status and future prospects of breast cancer screening using ultrasonography at our facility

    International Nuclear Information System (INIS)

    Morikubo, Hiroshi; Ichimura, Miyuki; Abe, Satoko

    2011-01-01

    We report the results obtained by breast cancer screening of the general population using both ultrasonography and mammography conducted by the Tochigi Public Health Service Association. An investigation of breast cancer screening carried out on approximately 140,000 participants between 2000 and 2007 showed that ultrasonography and mammography are remarkably complementary for detection of breast cancer, particularly for women in their 40s and 50s, and that each modality improves the sensitivity of breast cancer detection by approximately 20%. The following issues are pivotal for establishing a breast cancer ultrasonography screening system that is able to maintain high precision and adequate efficiency: technical training of sonographers and physicians who must interpret the sonographic images, quality control of equipment, and an interpretation system that allows previous sonographs to be used as a reference. In independent combined screening systems using ultrasonography and mammography, the high recall rate becomes an issue. Comparative interpretation of sonographic images with previous sonographs is effective for resolving this. However, hopes abound for a comprehensive assessment system that allows simultaneous imaging and interpretation of both ultrasonography and mammography. (author)

  3. Salivary gland ultrasonography as a primary imaging tool for predicting efficacy of xerostomia treatment in patients with Sjögren's syndrome.

    Science.gov (United States)

    Takagi, Yukinori; Sumi, Misa; Nakamura, Hideki; Sato, Shuntaro; Kawakami, Atsushi; Nakamura, Takashi

    2016-02-01

    To evaluate ultrasonography (US) grading of salivary gland disease as a predictor of treatment efficacy for impaired salivary function in xerostomia patients with or without Sjögren's syndrome (SS). We retrospectively analysed the prognostic importance of salivary US grading in 317 patients (168 with SS and 149 without SS). US images of the parotid and submandibular glands in each patient were individually categorized into grades 0-4 based on the extent of damage to the gland; and the sum total grade of the two gland types on either side was assigned a US score of 0-8 for each patient. The relative importance of US score and demographic and clinical variables was assessed using stepwise multiple regression analysis after various durations of xerostomia treatment. Multiple regression analysis indicated that the baseline US score before treatment was the most important factor [standardized regression coefficient (β) = -0.523, t-statistic (t) = -7.967, P < 0.001] in predicting negative outcomes in SS patients. Treatment duration (β = 0.277, t = 4.225, P < 0.001) was also a significant but less important positive variable. On the other hand, US grading did not effectively predict treatment outcomes in non-SS patients, with treatment duration (β = 0.199, t = 2.486, P = 0.014) and baseline salivary flow rate before treatment (β = -0.172, t = -2.159, P = 0.032) being significant but weak predictors of positive and negative outcome, respectively. Salivary gland US grading may help to predict outcomes of treatment for impaired salivary function in patients with SS. © The Author 2015. Published by Oxford University Press on behalf of the British Society for Rheumatology. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  4. Comparison of ultrasonography and radiography in diagnosis of rib fractures.

    Science.gov (United States)

    Pishbin, Elham; Ahmadi, Koorosh; Foogardi, Molood; Salehi, Maryam; Seilanian Toosi, Farrokh; Rahimi-Movaghar, Vafa

    2017-08-01

    Rib fractures are the most common skeletal thoracic injuries resulting from blunt chest trauma. Half of the rib fractures are not detected upon a precise physical evaluation and radiographs. Recently ultrasonography (USG) has been investigated to detect rib fractures. But based on literature the usefulness of USG varies widely. This study was conducted to investigate the role of USG in the detection of possible rib fractures in comparison with radiography. In this cross-sectional study, consecutive patients with minor blunt chest trauma and suspected rib fractures presenting in Imam Reza Hospital located in Mashhad-Iran, between April 2013 and October 2013 were assessed by USG and radiography. The radiography was performed in a posteroanterior (PA) chest projection and oblique rib view centered over the area of trauma. The time duration spent in taking USG and radiography were recorded. The prevalence and location of fractures revealed by USG and radiography were compared. Sixty-one suspected patients were assessed. The male to female ratio was 2.4:1 (43 men and 18 women) with a mean ± SD age of (44.3 ± 19.7) years. There were totally 59 rib fractures in 38 (62.3%) patients based on radiography and USG, while 23 (37.7%) patients had no diagnostic evidence of rib lesions. USG revealed 58 rib fractures in 33 (54.1%) of 61 suspected patients and radiographs revealed 32 rib fractures in 20 (32.8%) of 61 patients. A total of 58 (98.3%) rib fractures were detected by USG, whereas oblique rib view and PA chest radiography showed 27 (45.8%) and 24 (40.7%) rib fractures, respectively. The average duration of USG was (12 ± 3) min (range 7-17 min), whereas the duration of radiography was (27 ± 6) min (range 15-37 min). The kappa coefficient showed a low level of agreement between both USG and PA chest radiography (kappa coefficient = 0.28), and between USG and oblique rib view (kappa coefficient = 0.32). USG discloses more fractures than radiography in

  5. Predictors of diagnostic success with renal artery duplex ultrasonography.

    Science.gov (United States)

    Hedayati, Nasim; Del Pizzo, David J; Harris, Sean E; Kuskowski, Michael; Pevec, William C; Lee, Eugene S; Pifer, Christy; Dawson, David L

    2011-05-01

    Renal artery duplex ultrasonography (RA-DUS) is commonly used for the evaluation and follow-up of renal artery atherosclerotic disease. In a complete study, renal artery flow is evaluated from the vessel origin to the intraparenchymal branches. The quality of RA-DUS is in part technologist-dependent, but many factors may affect the ability to complete a diagnostic examination. This study evaluated the clinical and technical factors that predict the ability to obtain a complete RA-DUS examination. A prospective evaluation of all patients undergoing RA-DUS between July 2008 and February 2009 was performed. Factors such as patient age, gender, body mass index, technologists' years of experience, patient care setting (inpatient vs. outpatient), bedside examination, smoking before the examination, fasting status, and recent abdominal surgery were all recorded. Multivariate logistic regression analysis was performed. A p value of ≤ 0.05 was considered significant. During the study period, 250 patients underwent RA-DUS (mean age: 59.9 ± 17.8 years, 57% [143] female). A total of 87 (35%) examinations were incomplete. This included nondiagnostic examinations which did not exhibit any segment of the renal artery. Factors that were associated with an incomplete examination included technologists' years of experience (OR = 0.92, p = 0.042), bedside examination (OR = 4.17, p = 0.016), and recent abdominal surgery (OR = 3.45, p = 0.047). Body mass index, fasting status, and smoking before the examination did not affect the ability to obtain a complete study. One-third of the RA-DUS studies were classified as incomplete by the strict criteria used in this prospective study. An experienced ultrasound technologist is more likely to obtain a complete RA-DUS examination. Recent abdominal surgery and bedside examinations were predictive of a limited examination as well. Vascular laboratories should consider these factors when scheduling examinations so as to obtain complete RA

  6. Measurement of Gallbladder Volume with Ultrasonography in Pregnant Women

    Directory of Open Access Journals (Sweden)

    Sait Kapicioglu

    2000-01-01

    Full Text Available Fasting and postprandial gallbladder volumes were investigated using ultrasonography in three groups (10 subjects in each of healthy women: third trimester pregnant women, postpartum women up to 10 days after giving birth and nonpregnant controls. The scans were performed at 09:00 after a 12 h fast. After the basal measurement was taken, gallbladder volumes were rescanned in 15 min intervals for 60 mins. At the end of this period, all volunteers received a standard liquid test meal, and scans were performed again for 1 h. The mean basal gallbladder volume was 22.2±4.2 mL in the nonpregnant (control group. In the third trimester group, the basal volume was 37.8±10.5 mL – 70.5% higher than in the nonpregnant group (P<0.001. In the postpartum group, the mean basal volume was 37.9% lower (27.4±6.5 mL than that of the third trimester group (P<0.02. This basal volume was 23.6% greater than that of the control group (P<0.05. After administration of a test meal, the postprandial gallbladder volumes decreased during the first few minutes compared with baseline values. The volumes decreased by 10.2% to 39.8% (23.5±7.3 to 34.0±10.2; P<0.01 in the third trimester group, by 14.9% to 43.2% (16.6±4.3 to 23.3±5.5; P<0.01, 0.001 in the postpartum group and by 19.2% to 51.6% (11.9±3.5 to 17.9±3.6; P<0.02, 0.05, 0.01, 0.001 in the control group. Postprandial mean gallbladder volumes of the third trimester (P<0.02 and postpartum groups (P<0.02 to 0.01 were significantly different from those of the control group. In conclusion, incomplete emptying of the gallbladder after eating during the third trimester of pregnancy may contribute to cholesterol-gallstone formation, and pregnancy may thus increase the risk of gallstones.

  7. Graded tensor calculus

    International Nuclear Information System (INIS)

    Scheunert, M.

    1982-10-01

    We develop a graded tensor calculus corresponding to arbitrary Abelian groups of degrees and arbitrary commutation factors. The standard basic constructions and definitions like tensor products, spaces of multilinear mappings, contractions, symmetrization, symmetric algebra, as well as the transpose, adjoint, and trace of a linear mapping, are generalized to the graded case and a multitude of canonical isomorphisms is presented. Moreover, the graded versions of the classical Lie algebras are introduced and some of their basic properties are described. (orig.)

  8. Evaluation of mammogram compression efficiency

    International Nuclear Information System (INIS)

    Przelaskowski, A.; Surowski, P.; Kukula, A.

    2005-01-01

    Lossy image coding significantly improves performance over lossless methods, but a reliable control of diagnostic accuracy regarding compressed images is necessary. The acceptable range of compression ratios must be safe with respect to as many objective criteria as possible. This study evaluates the compression efficiency of digital mammograms in both numerically lossless (reversible) and lossy (irreversible) manner. Effective compression methods and concepts were examined to increase archiving and telediagnosis performance. Lossless compression as a primary applicable tool for medical applications was verified on a set 131 mammograms. Moreover, nine radiologists participated in the evaluation of lossy compression of mammograms. Subjective rating of diagnostically important features brought a set of mean rates given for each test image. The lesion detection test resulted in binary decision data analyzed statistically. The radiologists rated and interpreted malignant and benign lesions, representative pathology symptoms, and other structures susceptible to compression distortions contained in 22 original and 62 reconstructed mammograms. Test mammograms were collected in two radiology centers for three years and then selected according to diagnostic content suitable for an evaluation of compression effects. Lossless compression efficiency of the tested coders varied, but CALIC, JPEG-LS, and SPIHT performed the best. The evaluation of lossy compression effects affecting detection ability was based on ROC-like analysis. Assuming a two-sided significance level of p=0.05, the null hypothesis that lower bit rate reconstructions are as useful for diagnosis as the originals was false in sensitivity tests with 0.04 bpp mammograms. However, verification of the same hypothesis with 0.1 bpp reconstructions suggested their acceptance. Moreover, the 1 bpp reconstructions were rated very similarly to the original mammograms in the diagnostic quality evaluation test, but the

  9. Compression etiology in tendinopathy.

    Science.gov (United States)

    Almekinders, Louis C; Weinhold, Paul S; Maffulli, Nicola

    2003-10-01

    Recent studies have emphasized that the etiology of tendinopathy is not as simple as was once thought. The etiology is likely to be multifactorial. Etiologic factors may include some of the traditional factors such as overuse, inflexibility, and equipment problems; however, other factors need to be considered as well, such as age-related tendon degeneration and biomechanical considerations as outlined in this article. More research is needed to determine the significance of stress-shielding and compression in tendinopathy. If they are confirmed to play a role, this finding may significantly alter our approach in both prevention and in treatment through exercise therapy. The current biomechanical studies indicate that certain joint positions are more likely to place tensile stress on the area of the tendon commonly affected by tendinopathy. These joint positions seem to be different than the traditional positions for stretching exercises used for prevention and rehabilitation of tendinopathic conditions. Incorporation of different joint positions during stretching exercises may exert more uniform, controlled tensile stress on these affected areas of the tendon and avoid stresshielding. These exercises may be able to better maintain the mechanical strength of that region of the tendon and thereby avoid injury. Alternatively, they could more uniformly stress a healing area of the tendon in a controlled manner, and thereby stimulate healing once an injury has occurred. Additional work will have to prove if a change in rehabilitation exercises is more efficacious that current techniques.

  10. Compressible Vortex Ring

    Science.gov (United States)

    Elavarasan, Ramasamy; Arakeri, Jayawant; Krothapalli, Anjaneyulu

    1999-11-01

    The interaction of a high-speed vortex ring with a shock wave is one of the fundamental issues as it is a source of sound in supersonic jets. The complex flow field induced by the vortex alters the propagation of the shock wave greatly. In order to understand the process, a compressible vortex ring is studied in detail using Particle Image Velocimetry (PIV) and shadowgraphic techniques. The high-speed vortex ring is generated from a shock tube and the shock wave, which precedes the vortex, is reflected back by a plate and made to interact with the vortex. The shadowgraph images indicate that the reflected shock front is influenced by the non-uniform flow induced by the vortex and is decelerated while passing through the vortex. It appears that after the interaction the shock is "split" into two. The PIV measurements provided clear picture about the evolution of the vortex at different time interval. The centerline velocity traces show the maximum velocity to be around 350 m/s. The velocity field, unlike in incompressible rings, contains contributions from both the shock and the vortex ring. The velocity distribution across the vortex core, core diameter and circulation are also calculated from the PIV data.

  11. A comparison of intermittent pneumatic compression of the calf and whole leg in preventing deep venous thrombosis in urological surgery.

    Science.gov (United States)

    Soderdahl, D W; Henderson, S R; Hansberry, K L

    1997-05-01

    Intermittent pneumatic compression of the calf and/or thigh effectively decreases the incidence of deep venous thrombosis and other thrombotic sequelae but clinical data comparing these modalities are currently lacking. A total of 90 patients undergoing major urological surgery was randomly assigned to receive calf length or thigh length pneumatic compression for antithrombotic prophylaxis. Duplex ultrasound of the lower extremities was performed preoperatively and twice postoperatively to evaluate for deep venous thrombosis. Health care providers in the operating room, recovery room and ward were asked to compare the compression systems, and a cost analysis was performed. A total of 47 patients wore the thigh length sequential pneumatic sleeves and 43 wore calf length uniform compression systems. A pulmonary embolus without evidence of deep venous thrombosis was detected in 1 patient (2%) using the thigh length system. A thrombus was detected in the common femoral vein by duplex ultrasonography in 1 patient (2%) with the calf length system. Nursing personnel found the calf length sleeves easier to apply and more comfortable by patient account but they were satisfied with both systems. There was a significant cost savings with the calf length pneumatic compression system. Calf and thigh length pneumatic compression systems similarly decrease the risk of deep venous thrombosis in patients undergoing urological surgery. The calf length system has the added advantage of being less expensive and easier to use.

  12. Correlation of Body Mass Index and Serum Parameters With Ultrasonographic Grade of Fatty Change in Non-alcoholic Fatty Liver Disease.

    Science.gov (United States)

    Abangah, Ghobad; Yousefi, Atefeh; Asadollahi, Rouhangiz; Veisani, Yousef; Rahimifar, Paria; Alizadeh, Sajjad

    2014-01-01

    Non-alcoholic fatty liver disease (NAFLD) is a common liver disease in the western population and expanding disease in the world. Pathological changes in fatty liver are like alcohol liver damage, which can lead to end-stage liver disease. The prevalence of NAFLD in obese or overweight people is higher than general population, and it seems that people with high Body Mass Index (BMI) or abnormality in some laboratory tests are more susceptible for severe fatty liver and high grade of NAFLD in ultrasonography (U.S). This study aimed to evaluate the correlation of BMI and laboratory tests with NAFLD in ultrasonography. During a multi-step process, we selected two-hundred and thirteen cases from four hundred and eighteen patients with NAFLD. Laboratory tests performed included: ALT, AST, FBS, Triglyceride and cholesterol levels, hepatitis B surface antigen, hepatitis C antibody, ceruloplasmin, serum iron, TIBC, transferrin saturation, ferritin, AMA, ANA, ANTI LKM1, serum protein electrophoresis, TSH, anti TTG (IgA). BMI and ultrasonography for 213 patients were performed, and then data was analyzed. These parameters and grades of ultrasonography were compared with the values obtained using one way ANOVA. An ordinal logistic regression model was used to estimate the probability of ultrasonography grade. The Statistical Package for the Social Science program (SPSS, version 16.0) was used for data analysis. Two-hundred and thirteen cases including 140 male and 73 female, were studied. In general, 72.3% of patients were overweight and obese. Post-hoc tests showed that only BMI (P < 0.001) and TG (P < 0.011) among variables had statistically significant associations with ultrasonography grade (USG), and ordinal logistic regression model showed that BMI and AST were the best predictors. Our results suggest that in patients with NAFLD, BMI and TG are most effective factors in severity of fatty liver disease and ultrasonography grade (USG). On the other hand, BMI as a

  13. Diagnosis and treatment of postoperative intraperitoneal abscess using ultrasonography and abdominal computed tomography

    International Nuclear Information System (INIS)

    Kamachi, Hisashi; Kumashiro, Ryunosuke; Maekawa, Takafumi; Saku, Haruhisa; Naitoh, Hideaki; Inutsuka, Sadamitsu; Higashi, Yoshitaka

    1988-01-01

    Ultrasonography and/or abdominal computed tomography revealed 9 patients with subphrenic abscesses derived from gastrointestinal surgery. Out of them 4 cases underwent conservative treatment is chosen with aggresive chemotherapy, but 5 were re-surgically treated including drainage of the intraperitonial abscess or repairing the leakage of the anastomosis. On the conservative treatment for the intraperitonial abscess, frequent monitoring with ultrasonography was very conventional for successful treatment. However, in the cases with severe leukocytosis, leakage of anastomosis or recurrent intraperitonial abscess, resurgical treatment will be required. Thus the monitoring with ultrasonography is quite usefull not only in the drainaging of the intraperitonial abscess, but also in the judgement of treatment whether conservetive or re-operative. (author)

  14. Diagnostic Ultrasonography of an Ankle Fracture Undetectable by Conventional Radiography: A Case Report

    Science.gov (United States)

    Daniels, Clinton J.; Welk, Aaron B.; Enix, Dennis E.

    2016-01-01

    Objective The purpose of this study is to present diagnostic ultrasonography assessment of an occult fracture in a case of persistent lateral ankle pain. Clinical Features A 35-year-old woman presented to a chiropractic clinic with bruising, swelling, and pain along the distal fibula 3 days following an inversion ankle trauma. Prior radiographic examination at an urgent care facility was negative for fracture. Conservative care over the next week noted improvement in objective findings, but the pain persisted. Intervention and Outcome Diagnostic ultrasonography was ordered to assess her persistent ankle pain and showed a minimally displaced fracture of the fibula 4 cm proximal to the lateral malleolus. The patient was referred to her primary care physician and successfully managed with conservative care. Conclusion In this case, diagnostic ultrasonography was able to identify a Danis-Weber subtype B1 fracture that was missed by plain film radiography. PMID:27069430

  15. Atrophy of foot muscles in diabetic patients can be detected with ultrasonography

    DEFF Research Database (Denmark)

    Severinsen, Kaare; Obel, Annette; Jakobsen, Johannes

    2007-01-01

    OBJECTIVE: To establish a bedside test with ultrasonography for evaluation of foot muscle atrophy in diabetic patients. RESEARCH DESIGN AND METHODS: Thickness and cross-sectional area (CSA) of the extensor digitorum brevis muscle (EDB) and of the muscles of the first interstitium (MILs) were...... determined in 26 diabetic patients and in 26 matched control subjects using ultrasonography. To estimate the validity, findings were related to the total volume of all foot muscles determined at magnetic resonance imaging (MRI-FM(vol)). Furthermore, the relations of ultrasonographic estimates to nerve...... than in nonneuropathic diabetic patients (5.8 +/- 2.1 vs. 7.5 +/- 1.7 mm [P foot muscles determined at ultrasonography is directly related to foot muscle volume determined by MRI and to various...

  16. Advances in compressible turbulent mixing

    International Nuclear Information System (INIS)

    Dannevik, W.P.; Buckingham, A.C.; Leith, C.E.

    1992-01-01

    This volume includes some recent additions to original material prepared for the Princeton International Workshop on the Physics of Compressible Turbulent Mixing, held in 1988. Workshop participants were asked to emphasize the physics of the compressible mixing process rather than measurement techniques or computational methods. Actual experimental results and their meaning were given precedence over discussions of new diagnostic developments. Theoretical interpretations and understanding were stressed rather than the exposition of new analytical model developments or advances in numerical procedures. By design, compressibility influences on turbulent mixing were discussed--almost exclusively--from the perspective of supersonic flow field studies. The papers are arranged in three topical categories: Foundations, Vortical Domination, and Strongly Coupled Compressibility. The Foundations category is a collection of seminal studies that connect current study in compressible turbulent mixing with compressible, high-speed turbulent flow research that almost vanished about two decades ago. A number of contributions are included on flow instability initiation, evolution, and transition between the states of unstable flow onset through those descriptive of fully developed turbulence. The Vortical Domination category includes theoretical and experimental studies of coherent structures, vortex pairing, vortex-dynamics-influenced pressure focusing. In the Strongly Coupled Compressibility category the organizers included the high-speed turbulent flow investigations in which the interaction of shock waves could be considered an important source for production of new turbulence or for the enhancement of pre-existing turbulence. Individual papers are processed separately

  17. Mammography image compression using Wavelet

    International Nuclear Information System (INIS)

    Azuhar Ripin; Md Saion Salikin; Wan Hazlinda Ismail; Asmaliza Hashim; Norriza Md Isa

    2004-01-01

    Image compression plays an important role in many applications like medical imaging, televideo conferencing, remote sensing, document and facsimile transmission, which depend on the efficient manipulation, storage, and transmission of binary, gray scale, or color images. In Medical imaging application such Picture Archiving and Communication System (PACs), the image size or image stream size is too large and requires a large amount of storage space or high bandwidth for communication. Image compression techniques are divided into two categories namely lossy and lossless data compression. Wavelet method used in this project is a lossless compression method. In this method, the exact original mammography image data can be recovered. In this project, mammography images are digitized by using Vider Sierra Plus digitizer. The digitized images are compressed by using this wavelet image compression technique. Interactive Data Language (IDLs) numerical and visualization software is used to perform all of the calculations, to generate and display all of the compressed images. Results of this project are presented in this paper. (Author)

  18. Advances in compressible turbulent mixing

    Energy Technology Data Exchange (ETDEWEB)

    Dannevik, W.P.; Buckingham, A.C.; Leith, C.E. [eds.

    1992-01-01

    This volume includes some recent additions to original material prepared for the Princeton International Workshop on the Physics of Compressible Turbulent Mixing, held in 1988. Workshop participants were asked to emphasize the physics of the compressible mixing process rather than measurement techniques or computational methods. Actual experimental results and their meaning were given precedence over discussions of new diagnostic developments. Theoretical interpretations and understanding were stressed rather than the exposition of new analytical model developments or advances in numerical procedures. By design, compressibility influences on turbulent mixing were discussed--almost exclusively--from the perspective of supersonic flow field studies. The papers are arranged in three topical categories: Foundations, Vortical Domination, and Strongly Coupled Compressibility. The Foundations category is a collection of seminal studies that connect current study in compressible turbulent mixing with compressible, high-speed turbulent flow research that almost vanished about two decades ago. A number of contributions are included on flow instability initiation, evolution, and transition between the states of unstable flow onset through those descriptive of fully developed turbulence. The Vortical Domination category includes theoretical and experimental studies of coherent structures, vortex pairing, vortex-dynamics-influenced pressure focusing. In the Strongly Coupled Compressibility category the organizers included the high-speed turbulent flow investigations in which the interaction of shock waves could be considered an important source for production of new turbulence or for the enhancement of pre-existing turbulence. Individual papers are processed separately.

  19. Ability of Ultrasonography in Detection of Different Extremity Bone Fractures; a Case Series Study.

    Science.gov (United States)

    Bozorgi, Farzad; Shayesteh Azar, Massoud; Montazer, Seyed Hossein; Chabra, Aroona; Heidari, Seyed Farshad; Khalilian, Alireza

    2017-01-01

    Despite radiography being the gold standard in evaluation of orthopedic injuries, using bedside ultrasonography has several potential supremacies such as avoiding exposure to ionizing radiation, availability in pre-hospital settings, being extensively accessible, and ability to be used on the bedside. The aim of the present study is to evaluate the diagnostic accuracy of ultrasonography in detection of extremity bone fractures. This study is a case series study, which was prospectively conducted on multiple blunt trauma patients, who were 18 years old or older, had stable hemodynamic, Glasgow coma scale 15, and signs or symptoms of a possible extremity bone fracture. After initial assessment, ultrasonography of suspected bones was performed by a trained emergency medicine resident and prevalence of true positive and false negative findings were calculated compared to plain radiology. 108 patients with the mean age of 44.6 ± 20.4 years were studied (67.6% male). Analysis was done on 158 sites of fracture, which were confirmed with plain radiography. 91 (57.6%) cases were suspected to have upper extremity fracture(s) and 67 (42.4%) to have lower ones. The most frequent site of injuries were forearm (36.7%) in upper limbs and leg (27.8%) in lower limbs. Prevalence of true positive and false negative cases for fractures detected by ultrasonography were 59 (64.8%) and 32 (35.52%) for upper and 49 (73.1%) and 18 (26.9%) for lower extremities, respectively. In addition, prevalence of true positive and false negative detected cases for intra-articular fractures were 24 (48%) and 26 (52%), respectively. The present study shows the moderate sensitivity (68.3%) of ultrasonography in detection of different extremity bone fractures. Ultrasonography showed the best sensitivity in detection of femur (100%) and humerus (76.2%) fractures, respectively. It had low sensitivity in detection of in intra-articular fractures.

  20. Ultrasonographic detection of hepatocellular carcinoma: correlation of preoperative ultrasonography and resected liver pathology

    International Nuclear Information System (INIS)

    Lim, J.H.; Kim, S.H.; Lee, W.J.; Choi, D.; Kim, S.H.; Lim, H.K.

    2006-01-01

    AIM: The aim of this study was to determine the sensitivity of ultrasonography for detecting hepatocellular carcinoma in patients who underwent surgical liver resection. MATERIALS AND METHODS: The preoperative ultrasonography reports of 103 patients who underwent hepatic resection surgery were retrospectively reviewed. The patients had chronic liver disease with good liver function and a relatively normal liver echotexture. The presence of a mass or masses in the resected part of the liver segments on preoperative ultrasonography was regarded as possible hepatocellular carcinoma, and these results were compared with the surgically resected hepatic lobes or segments. Accuracy for detection was assessed on a lesion-by-lesion basis, on a segment-by-segment basis, and on a patient basis. RESULTS: One hundred and fifty-seven hepatocellular carcinomas were found in 244 hepatic segments of 103 patients. One hundred and one of 157 hepatocellular carcinomas were detected using ultrasonography in 97 patients resulting in a sensitivity of 64%. In six patients, a solitary hepatocellular carcinoma was missed in each patient, a patient sensitivity being 94%. Using ultrasonography, 87 of 100 (87%) hepatocellular carcinomas larger than 2 cm in diameter, and 14 of 57 (25%) hepatocellular carcinomas 2 cm or smaller in diameter were revealed. On the basis of segment-by-segment analysis, the sensitivity was 78% (99 of 127 segments), specificity was 97% (114 of 117 segments), accuracy was 87% (213 of 244 segments), positive predictive value was 97% (99 of 102 segments), and negative predictive value was 80% (114 of 142 segments). CONCLUSION: In patients with chronic liver disease and good hepatic function, ultrasonography has a sensitivity of 94% in the identification of affected patients, but for individual lesions, the sensitivity is only 64%

  1. Economic analysis of bedside ultrasonography (US) implementation in an Internal Medicine department.

    Science.gov (United States)

    Testa, Americo; Francesconi, Andrea; Giannuzzi, Rosangela; Berardi, Silvia; Sbraccia, Paolo

    2015-12-01

    The economic crisis, the growing healthcare demand, and Defensive Medicine wastefulness, strongly recommend the restructuring of the entire medical network. New health technology, such as bedside ultrasonography, might successfully integrate the clinical approach optimizing the use of limited resources, especially in a person-oriented vision of medicine. Bedside ultrasonography is a safe and reliable technique, with worldwide expanding employment in various clinical settings, being considered as "the stethoscope of the 21st century". However, at present, bedside ultrasonography lacks economic analysis. We performed a Cost-Benefit Analysis "ex ante", with a break-even point computing, of bedside ultrasonography implementation in an Internal Medicine department in the mid-term. Number and kind estimation of bedside ultrasonographic studies were obtained by a retrospective study, whose data results were applied to the next 3-year period (foresight study). All 1980 foreseen bedside examinations, with prevailing multiorgan ultrasonographic studies, were considered to calculate direct and indirect costs, while specific and generic revenues were considered only after the first semester. Physician professional training, equipment purchase and working time represented the main fixed and variable cost items. DRG increase/appropriateness, hospitalization stay shortening and reduction of traditional ultrasonography examination requests mainly impacted on calculated revenues. The break-even point, i.e. the volume of activity at which revenues exactly equal total incurred costs, was calculated to be 734 US examinations, corresponding to € 81,998 and the time considered necessary to reach it resulting 406 days. Our economic analysis clearly shows that bedside ultrasonography implementation in clinical daily management of an Internal Medicine department can produce consistent savings, or economic profit according to managerial choices (i.e., considering public or private targets

  2. The pitfalls of ultrasonography in the evaluation of soft tissue masses

    International Nuclear Information System (INIS)

    Kwok, Henry CK.; Pinto, Clinton H.; Doyle, Anthony J.

    2012-01-01

    Ultrasonography is associated with a high error rate in the evaluation of soft tissue masses. The purposes of this study were to examine the nature of the diagnostic errors and to identify areas in which reporting could be improved. Patients who had soft tissue tumours and received ultrasonography during a 10-year period (1999–2009) were identified from a local tumour registry. The sonographic and pathological diagnoses were categorised as either ‘benign’ or ‘non-benign’. The accuracy of ultrasonography was assessed by correlating the sonographic with the pathological diagnostic categories. Recommendations from radiologists, where offered, were assessed for their appropriateness in the context of the pathological diagnosis. One hundred seventy-five patients received ultrasonography, of which 60 had ‘non-benign’ lesions and 115 had ‘benign’ lesions. Ultrasonography correctly diagnosed 35 and incorrectly diagnosed seven of the 60 ‘non-benign’ cases, and did not suggest a diagnosis in 18 cases. Most of the diagnostic errors related to misdiagnosing soft tissue tumours as haematomas (four out of seven). Recommendations for further management were offered by the radiologists in 144 cases, of which 52 had ‘non-benign’ pathology. There were eight ‘non-benign’ cases where no recommendation was offered, and the sonographic diagnosis was either incorrect or unavailable. Ultrasonography lacks accuracy in the evaluation of soft tissue masses. Ongoing education is required to improve awareness of the limitations with its use. These limitations should be highlighted to the referrers, especially those who do not have specific training in this area.

  3. Evaluation of Ultrasonography as a Diagnostic Tool in Maxillofacial Space Infections

    Directory of Open Access Journals (Sweden)

    Praveen Kumar Pandey

    2011-11-01

    Full Text Available Objectives: The purpose of the study was to establish the role of ultrasonography in determining the involvement of specific fascial spaces in maxillofacial region and the stage of infection, in indicating the appropriate time for surgical intervention and to compare clinical and ultrasonographic findings.Material and Methods: Twenty five patients with fascial space infection in maxillofacial region were subjected to ultrasonographic examination following a detailed clinical and radiological examination. Ultrasonography guided needle aspiration was performed. Based on the findings, patients diagnosed with abscess were subjected to incision and drainage and those with cellulitis were subjected to medical line of treatment.Results: More than one fascial space was involved in all patients. On clinical examination 64 spaces were involved, of them 34 spaces had abscess formation and 30 spaces were in the stage of cellulitis. On ultrasonography examination, 28 spaces were reported to have abscess formation and 36 spaces were diagnosed to be in the stage of cellulitis. On comparative analysis of both clinical and ultrasonographic findings, ultrasonography was found to be sensitive in 65% of the cases and having specificity of 80%. It was registered statistically significant (P < 0.001 agreement between these two methods of assessment (kappa index = 0.814.Conclusions: Ultrasonography is a quick, widely available, relatively inexpensive, and painless procedure and can be repeated as often as necessary without risk to the patient. Thus ultrasonography is a valuable diagnostic aid to the oral and maxillofacial surgeon for early and accurate diagnosis of fascial space infection, their appropriate treatment and to limit their further spread.

  4. Comparison of JPEG and wavelet compression on intraoral digital radiographic images

    International Nuclear Information System (INIS)

    Kim, Eun Kyung

    2004-01-01

    To determine the proper image compression method and ratio without image quality degradation in intraoral digital radiographic images, comparing the discrete cosine transform (DCT)-based JPEG with the wavelet-based JPEG 2000 algorithm. Thirty extracted sound teeth and thirty extracted teeth with occlusal caries were used for this study. Twenty plaster blocks were made with three teeth each. They were radiographically exposed using CDR sensors (Schick Inc., Long Island, USA). Digital images were compressed to JPEG format, using Adobe Photoshop v. 7.0 and JPEG 2000 format using Jasper program with compression ratios of 5 : 1, 9 : 1, 14 : 1, 28 : 1 each. To evaluate the lesion detectability, receiver operating characteristic (ROC) analysis was performed by the three oral and maxillofacial radiologists. To evaluate the image quality, all the compressed images were assessed subjectively using 5 grades, in comparison to the original uncompressed images. Compressed images up to compression ratio of 14: 1 in JPEG and 28 : 1 in JPEG 2000 showed nearly the same the lesion detectability as the original images. In the subjective assessment of image quality, images up to compression ratio of 9 : 1 in JPEG and 14 : 1 in JPEG 2000 showed minute mean paired differences from the original images. The results showed that the clinically acceptable compression ratios were up to 9 : 1 for JPEG and 14 : 1 for JPEG 2000. The wavelet-based JPEG 2000 is a better compression method, comparing to DCT-based JPEG for intraoral digital radiographic images.

  5. Context-Aware Image Compression.

    Directory of Open Access Journals (Sweden)

    Jacky C K Chan

    Full Text Available We describe a physics-based data compression method inspired by the photonic time stretch wherein information-rich portions of the data are dilated in a process that emulates the effect of group velocity dispersion on temporal signals. With this coding operation, the data can be downsampled at a lower rate than without it. In contrast to previous implementation of the warped stretch compression, here the decoding can be performed without the need of phase recovery. We present rate-distortion analysis and show improvement in PSNR compared to compression via uniform downsampling.

  6. Compressive sensing for urban radar

    CERN Document Server

    Amin, Moeness

    2014-01-01

    With the emergence of compressive sensing and sparse signal reconstruction, approaches to urban radar have shifted toward relaxed constraints on signal sampling schemes in time and space, and to effectively address logistic difficulties in data acquisition. Traditionally, these challenges have hindered high resolution imaging by restricting both bandwidth and aperture, and by imposing uniformity and bounds on sampling rates.Compressive Sensing for Urban Radar is the first book to focus on a hybrid of two key areas: compressive sensing and urban sensing. It explains how reliable imaging, tracki

  7. Randomized clinical trial of laparoscopic ultrasonography before laparoscopic colorectal cancer resection

    DEFF Research Database (Denmark)

    Ellebaek, S B; Fristrup, C W; Hovendal, C

    2017-01-01

    BACKGROUND: Intraoperative ultrasonography during open surgery for colorectal cancer may be useful for the detection of unrecognized liver metastases. Laparoscopic ultrasonography (LUS) for the detection of unrecognized liver metastasis has not been studied in a randomized trial. This RCT tested...... in the LUS than in the control group (7·8 (95 per cent c.i. 3·8 to 13·8) and 0·8 (0 to 4·2) per cent respectively; P = 0·010), but the suspected M1 disease was benign in half of the patients. CONCLUSION: Routine LUS during resection of colorectal cancer is not recommended. Registration number: NCT02079389...

  8. A Case of Fetal Herpes Simplex Encephalitis Diagnosed Prenatally by Ultrasonography in the Third Trimester

    International Nuclear Information System (INIS)

    Lee, Mi Bum; Kim, Yu Ri; Hwang, Han Sung; Park, Yong Won; Kim, Young Han

    2007-01-01

    Almost all reported incidences of herpes simplex virus (HSV) infection in newborns result as a complication of rupture of the amniotic membranes or the delivery of the baby, but infection via the placenta and amniotic membranes is rare. Ventriculomegaly was detected at 36 weeks of gestation by prenatal ultrasonography, and an emergency cesarean section was then performed at 36 weeks of gestation. We report a case of herpes simplex encephalitis detected at 36 weeks of gestation by prenatal ultrasonography, which was confirmed by a postnatal serologic test and CSF test with a brief review of literature

  9. Reproducibility of ultrasonography for assessing abdominal fat distribution in a population at high risk of diabetes

    DEFF Research Database (Denmark)

    Philipsen, A; Carstensen, Bendix; Sandbæk, Annelli

    2013-01-01

    the reproducibility of this method have been published.Objective:The aim of this study was to investigate the reproducibility of ultrasonography in the assessment of abdominal fat distribution in a population at high risk of type 2 diabetes.Design and Methods:Ultrasonography was used to estimate visceral......- and interobserver variation, and Bland-Altman plots were drawn for all three substudies.Results:Coefficients of variation for intra- and interobserver variation were in the range 3.4-6.1%, except for interobserver variation for subcutaneous fat (9.5%). Short-term variation over a median of 35 days had a coefficient...

  10. Color Doppler Ultrasonography-Targeted Perforator Mapping and Angiosome-Based Flap Reconstruction

    DEFF Research Database (Denmark)

    Gunnarsson, Gudjon Leifur; Tei, Troels; Thomsen, Jørn Bo

    2016-01-01

    Knowledge about perforators and angiosomes has inspired new and innovative flap designs for reconstruction of defects throughout the body. The purpose of this article is to share our experience using color Doppler ultrasonography (CDU)-targeted perforator mapping and angiosome-based flap reconstr......Knowledge about perforators and angiosomes has inspired new and innovative flap designs for reconstruction of defects throughout the body. The purpose of this article is to share our experience using color Doppler ultrasonography (CDU)-targeted perforator mapping and angiosome-based flap...

  11. Comparison of radiography and ultrasonography in the evaluation of renal lesions in the dog

    International Nuclear Information System (INIS)

    Konde, L.J.; Park, R.D.; Wrigley, R.H.; Lebel, J.L.

    1986-01-01

    Survey abdominal radiographs, excretory urograms, and nephrosonograms were obtained from 14 dogs with renal lesions. Renal enlargement was suspected on survey radiographs and confirmed by excretory urography in 13 dogs. Radiographic differentiation between a solid and cystic renal lesion was not possible in 9 dogs. Ultrasonography determined the presence of solid masses in 12 dogs, established the presence of a renal cyst in the opposite kidney in 1 dog, and revealed hydronephrosis in 2 dogs. Ultrasonography appeared to be more sensitive than radiography in differentiating the internal characteristics of renal lesions

  12. A Case of Fetal Herpes Simplex Encephalitis Diagnosed Prenatally by Ultrasonography in the Third Trimester

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Mi Bum; Kim, Yu Ri; Hwang, Han Sung; Park, Yong Won; Kim, Young Han [Yonsei University College of Medicine, Seoul (Korea, Republic of)

    2007-12-15

    Almost all reported incidences of herpes simplex virus (HSV) infection in newborns result as a complication of rupture of the amniotic membranes or the delivery of the baby, but infection via the placenta and amniotic membranes is rare. Ventriculomegaly was detected at 36 weeks of gestation by prenatal ultrasonography, and an emergency cesarean section was then performed at 36 weeks of gestation. We report a case of herpes simplex encephalitis detected at 36 weeks of gestation by prenatal ultrasonography, which was confirmed by a postnatal serologic test and CSF test with a brief review of literature

  13. HIGH-RESOLUTION ULTRASONOGRAPHY OF SHOULDER FOR ROTATOR CUFF TEAR: CORRELATION WITH ARTHROSCOPIC FINDINGS

    Directory of Open Access Journals (Sweden)

    Vishnumurthy H. Y

    2016-09-01

    Full Text Available INTRODUCTION Rotator cuff disease is the most common cause of shoulder pain. Ultrasonography being non-invasive, widely available, more cost-effective method and is the first choice in imaging of rotator cuff tears. Arthroscopy of shoulder is considered as the gold standard for diagnosis of rotator cuff tears. Objective of this study was to compare the diagnostic accuracy of high-resolution ultrasonography of shoulder for rotator cuff tears with arthroscopy of shoulder. METHODS Thirty patients clinically suspected to have rotator cuff tear who underwent ultrasonography and arthroscopy of shoulder were included in the study. Duration of study was for two years. All ultrasonography examinations were conducted in ultrasound machine using GE Voluson 730 PRO high frequency (10-12 MHz linear array transducer done by two experienced radiologists. Arthroscopies were done by two experienced shoulder arthroscopic surgeons. RESULTS Age of the patients with rotator cuff tears ranged from 40 to 80 years. 57% were females and 43% were males among the patients who had rotator cuff tears. 71.43% of the rotator cuff tears were found in the dominant arm. 64.28% of patients with rotator cuff tear had given history of fall or trauma to the corresponding shoulder within 6 months prior to presentation. 39.28% of patients who had rotator cuff tears were known diabetics. Supraspinatus tendon was the most commonly affected tendon, followed by infraspinatus and subscapularis tendons. For overall detection of rotator cuff tears, ultrasonography in comparison with the arthroscopy has sensitivity and specificity of 92.85% and 100%. For detection of full thickness rotator cuff tear, its sensitivity and specificity was 94.73% and 100% and for partial thickness rotator cuff tears 76.92% and 100%. Ultrasonography has 100% sensitivity and specificity for detection of supraspinatus full thickness tear. For supraspinatus partial thickness tear, sensitivity and specificity was 88

  14. Comparative study of ultrasonography, computed tomography, magnetic resonance imaging, and magnetic resonance spectroscopy for the diagnosis for fatty liver in a rat model

    International Nuclear Information System (INIS)

    Noh, Hoon; Song, Xiao Li; Heo, Suk Hee; Kim, Jin Woong; Jeong, Yong Yeon; Kang, Heoung Keun; Shin, Sang Soo; Ahn, Kyu Youn

    2017-01-01

    To compare the accuracy of ultrasonography (US), single-energy CT (SECT), dual-energy CT (DECT), MR imaging (MRI), and MR spectroscopy (MRS) for detecting fatty liver in a rat model. Fatty liver was induced by 60% high-fat diet for 1, 2, 3, 4, or 5 weeks (3 rats per group, a total of 15 rats). The control group comprised of five rats fed 10% high-fat diet. US, SECT, DECT, MRI, and MRS of the liver were performed weekly. Histologic steatosis grade and intrahepatocelluar triglyceride level were determined histologically for the livers of sacrificed rats. Pearson correlation test was used to assess the correlation between examinations and standard reference levels. Receiver operating characteristic curves were constructed. Area under the curve (AUC), sensitivity, and specificity were calculated. US, SECT, DECT, MRI, and MRS were significantly correlated with histologic steatosis grade. The diagnostic performance of AUC, sensitivity, and specificity were 0.893, 80%, and 80% for US, 0.960, 80%, and 80% for SECT, 0.947, 100%, and 60% for DECT, 0.933, 93.3%, and 100% for MRI, and 0.960, 93.3%, and 100% for MRS. MRS showed the strongest correlation with histologic steatosis grade with the highest sensitivity and specificity for diagnosis of fatty liver compared to other modalities

  15. Comparative study of ultrasonography, computed tomography, magnetic resonance imaging, and magnetic resonance spectroscopy for the diagnosis for fatty liver in a rat model

    Energy Technology Data Exchange (ETDEWEB)

    Noh, Hoon; Song, Xiao Li; Heo, Suk Hee; Kim, Jin Woong; Jeong, Yong Yeon; Kang, Heoung Keun [Dept. of Radiology, Chonnam National University Hwasun Hospital, Hwasun (Korea, Republic of); Shin, Sang Soo [Dept. of Radiology, Chonnam National University Hospital, Gwangju (Korea, Republic of); Ahn, Kyu Youn [Dept. of Anatomy, Chonnam National University Medical School, Gwangju (Korea, Republic of)

    2017-01-15

    To compare the accuracy of ultrasonography (US), single-energy CT (SECT), dual-energy CT (DECT), MR imaging (MRI), and MR spectroscopy (MRS) for detecting fatty liver in a rat model. Fatty liver was induced by 60% high-fat diet for 1, 2, 3, 4, or 5 weeks (3 rats per group, a total of 15 rats). The control group comprised of five rats fed 10% high-fat diet. US, SECT, DECT, MRI, and MRS of the liver were performed weekly. Histologic steatosis grade and intrahepatocelluar triglyceride level were determined histologically for the livers of sacrificed rats. Pearson correlation test was used to assess the correlation between examinations and standard reference levels. Receiver operating characteristic curves were constructed. Area under the curve (AUC), sensitivity, and specificity were calculated. US, SECT, DECT, MRI, and MRS were significantly correlated with histologic steatosis grade. The diagnostic performance of AUC, sensitivity, and specificity were 0.893, 80%, and 80% for US, 0.960, 80%, and 80% for SECT, 0.947, 100%, and 60% for DECT, 0.933, 93.3%, and 100% for MRI, and 0.960, 93.3%, and 100% for MRS. MRS showed the strongest correlation with histologic steatosis grade with the highest sensitivity and specificity for diagnosis of fatty liver compared to other modalities.

  16. Fatty liver diagnostic from medical examination to analyze the accuracy between the abdominal ultrasonography and liver hounsfield units

    International Nuclear Information System (INIS)

    Oh, Wang Kyun; Kim, Sang Hyun

    2017-01-01

    In abdominal Ultrasonography, the fatty liver is diagnosed through hepatic parenchymal echo increased parenchymal density and unclear blood vessel boundary, and according to many studies, abdominal Ultrasonography has 60 ∼ 90% of sensitivity and 84 ∼ 95% of specificity in diagnosis of fatty liver, but the result of Ultrasonography is dependent on operators, so there can be difference among operators, and quantitative measurement of fatty infiltration is impossible. Among examinees who same day received abdominal Ultrasonography and chest computed tomography (CT), patients who were diagnosed with a fatty liver in the Ultrasonography were measured with liver Hounsfield Units (HU) of chest CT imaging to analyze the accuracy of the fatty liver diagnosis. Among 720 subject examinees, those who were diagnosed with a fatty liver through abdominal Ultrasonography by family physicians were 448, which is 62.2%. The result of Liver HU measurement in the chest CT imaging of those who were diagnosed with a fatty liver showed that 175 out of 720 had the measured value of less than 40 HU, which is 24.3%, and 173 were included to the 175 among 448 who were diagnosed through Ultrasonography, so 98.9% corresponded. This indicates that the operators' subjective ability has a great impact on diagnosis of lesion in Ultrasonography diagnosis of a fatty liver, and that in check up chest CT, under 40 HU in the measurement of Liver HU can be used for reference materials in diagnosis of a fatty liver

  17. Comparison of the diagnostic value of ultrasonography and standing radiography for pelvic-femoral disorders in horses.

    Science.gov (United States)

    Geburek, Florian; Rötting, Anna K; Stadler, Peter M

    2009-04-01

    To assess agreement between ultrasonography (transcutaneous and transrectal) and standing radiography in horses with fractures in the pelvic region and disorders of the coxofemoral joint. Case series. Warmblood horses (n=23) and 2 ponies. Medical records (1999-2008) of equids with pelvic or coxofemoral disorders that had pelvic radiography and ultrasonography were retrieved and results of both techniques compared. Radiography and ultrasonography each identified equal numbers of fractures of the tuber coxa (n=4), ilial shaft (2), ischium (3), femoral neck (2), and osteoarthritis/osis of the coxofemoral joint (6). Fractures of the ilial wing (4) were only identified by ultrasonography not by standing radiography. Of 9 acetabular fractures, 3 were identified on radiographs only, 5 were identified with both modalities. One pubic fracture was identified using ultrasonography and radiography. One acetabular and 1 pubic fracture were only diagnosed on necropsy. We found reasonable agreement (73%; 24/33) between ultrasonography and standing radiography for diagnosis of pelvic-femoral disorders. Ultrasonography was more useful for ilial wing fractures and radiography for acetabular fractures. Ultrasonography is a rapid, safe imaging technique for detecting disorders of the pelvic region with a high diagnostic yield and is a preferred initial approach in horses with severe hindlimb lameness.

  18. Fatty liver diagnostic from medical examination to analyze the accuracy between the abdominal ultrasonography and liver hounsfield units

    Energy Technology Data Exchange (ETDEWEB)

    Oh, Wang Kyun [Dept. of Radiology, Cheongju Medical Center, Cheongju (Korea, Republic of); Kim, Sang Hyun [Dept. of Radiological Science, Shinhan University, Uijeongbu (Korea, Republic of)

    2017-06-15

    In abdominal Ultrasonography, the fatty liver is diagnosed through hepatic parenchymal echo increased parenchymal density and unclear blood vessel boundary, and according to many studies, abdominal Ultrasonography has 60 ∼ 90% of sensitivity and 84 ∼ 95% of specificity in diagnosis of fatty liver, but the result of Ultrasonography is dependent on operators, so there can be difference among operators, and quantitative measurement of fatty infiltration is impossible. Among examinees who same day received abdominal Ultrasonography and chest computed tomography (CT), patients who were diagnosed with a fatty liver in the Ultrasonography were measured with liver Hounsfield Units (HU) of chest CT imaging to analyze the accuracy of the fatty liver diagnosis. Among 720 subject examinees, those who were diagnosed with a fatty liver through abdominal Ultrasonography by family physicians were 448, which is 62.2%. The result of Liver HU measurement in the chest CT imaging of those who were diagnosed with a fatty liver showed that 175 out of 720 had the measured value of less than 40 HU, which is 24.3%, and 173 were included to the 175 among 448 who were diagnosed through Ultrasonography, so 98.9% corresponded. This indicates that the operators' subjective ability has a great impact on diagnosis of lesion in Ultrasonography diagnosis of a fatty liver, and that in check up chest CT, under 40 HU in the measurement of Liver HU can be used for reference materials in diagnosis of a fatty liver.

  19. The Effectiveness of Ultrasonography in Detecting Emergent Pediatric Pathologies and Requirement for Additional Imaging Techniques: A Retrospective Study

    Directory of Open Access Journals (Sweden)

    Betül Tiryaki Baştuğ

    2018-04-01

    Full Text Available Introduction: In emergency cases, ultrasonography is used in guiding resuscitation, to provide procedural guidance, and confirm a clinical diagnosis. In addition, it may prevent unnecessary exposure of the patient to ionizing radiation and risks caused by transporting the patient away from monitoring. This paper aimed to evaluate the effectiveness of ultrasonography in detecting emergent pediatric pathologies in a state hospital radiology unit, and to identify whether additional imaging techniques, such as computed tomography, were required. Methods: This study was designed as a retrospective investigation. A group of 536 patients were randomly selected from 1.401 pediatric patients who underwent ultrasonography for non-traumatic emergent pathologies between 2015 and 2016. Results: Of the 536 patients, 46 were diagnosed with appendicitis, 14 with pathologies of the urinary system, 1 with ileus, 29 with mesenteric lymphadenitis, 4 with intussusception, 3 with ovarian cyst rupture, 1 with ovarian torsion, and 32 with scrotal pathologies. Computed tomography was performed for 20 patients. Ureteral calculi and appendicitis were confirmed by computed tomography in 5 and 14 patients, respectively, after being identified as secondary findings by ultrasonography. In 1 patient, ileus was verified by computed tomography. The sensitivity of ultrasonography was determined to be 85.7%. Only 14% of patients were not given definite pathological diagnoses by ultrasonography alone. Subsequent computed tomography for verifying secondary findings detected by ultrasonography was essential in only 20 patients. Conclusion: Our results promote the use of ultrasonography as the initial imaging test for evaluating pediatric patients with suspected emergency pathologies.

  20. Classroom: Efficient Grading

    Science.gov (United States)

    Shaw, David D.; Pease, Leonard F., III.

    2014-01-01

    Grading can be accelerated to make time for more effective instruction. This article presents specific time management strategies selected to decrease administrative time required of faculty and teaching assistants, including a multiple answer multiple choice interface for exams, a three-tier grading system for open ended problem solving, and a…

  1. Grain Grading and Handling.

    Science.gov (United States)

    Rendleman, Matt; Legacy, James

    This publication provides an introduction to grain grading and handling for adult students in vocational and technical education programs. Organized in five chapters, the booklet provides a brief overview of the jobs performed at a grain elevator and of the techniques used to grade grain. The first chapter introduces the grain industry and…

  2. Efficient Lossy Compression for Compressive Sensing Acquisition of Images in Compressive Sensing Imaging Systems

    Directory of Open Access Journals (Sweden)

    Xiangwei Li

    2014-12-01

    Full Text Available Compressive Sensing Imaging (CSI is a new framework for image acquisition, which enables the simultaneous acquisition and compression of a scene. Since the characteristics of Compressive Sensing (CS acquisition are very different from traditional image acquisition, the general image compression solution may not work well. In this paper, we propose an efficient lossy compression solution for CS acquisition of images by considering the distinctive features of the CSI. First, we design an adaptive compressive sensing acquisition method for images according to the sampling rate, which could achieve better CS reconstruction quality for the acquired image. Second, we develop a universal quantization for the obtained CS measurements from CS acquisition without knowing any a priori information about the captured image. Finally, we apply these two methods in the CSI system for efficient lossy compression of CS acquisition. Simulation results demonstrate that the proposed solution improves the rate-distortion performance by 0.4~2 dB comparing with current state-of-the-art, while maintaining a low computational complexity.

  3. Vascular grading of angiogenesis

    DEFF Research Database (Denmark)

    Hansen, S; Grabau, D A; Sørensen, Flemming Brandt

    2000-01-01

    The study aimed to evaluate the prognostic value of angiogenesis by vascular grading of primary breast tumours, and to evaluate the prognostic impact of adding the vascular grade to the Nottingham Prognostic Index (NPI). The investigation included 836 patients. The median follow-up time was 11...... years and 4 months. The microvessels were immunohistochemically stained by antibodies against CD34. Angiogenesis was graded semiquantitatively by subjective scoring into three groups according to the expected number of microvessels in the most vascular tumour area. The vascular grading between observers...... for 24% of the patients, who had a shift in prognostic group, as compared to NPI, and implied a better prognostic dissemination. We concluded that the angiogenesis determined by vascular grading has independent prognostic value of clinical relevance for patients with breast cancer....

  4. Vascular grading of angiogenesis

    DEFF Research Database (Denmark)

    Hansen, S; Grabau, D A; Sørensen, Flemming Brandt

    2000-01-01

    The study aimed to evaluate the prognostic value of angiogenesis by vascular grading of primary breast tumours, and to evaluate the prognostic impact of adding the vascular grade to the Nottingham Prognostic Index (NPI). The investigation included 836 patients. The median follow-up time was 11...... years and 4 months. The microvessels were immunohistochemically stained by antibodies against CD34. Angiogenesis was graded semiquantitatively by subjective scoring into three groups according to the expected number of microvessels in the most vascular tumour area. The vascular grading between observers...... impact for 24% of the patients, who had a shift in prognostic group, as compared to NPI, and implied a better prognostic dissemination. We concluded that the angiogenesis determined by vascular grading has independent prognostic value of clinical relevance for patients with breast cancer....

  5. Compressed gas fuel storage system

    Science.gov (United States)

    Wozniak, John J.; Tiller, Dale B.; Wienhold, Paul D.; Hildebrand, Richard J.

    2001-01-01

    A compressed gas vehicle fuel storage system comprised of a plurality of compressed gas pressure cells supported by shock-absorbing foam positioned within a shape-conforming container. The container is dimensioned relative to the compressed gas pressure cells whereby a radial air gap surrounds each compressed gas pressure cell. The radial air gap allows pressure-induced expansion of the pressure cells without resulting in the application of pressure to adjacent pressure cells or physical pressure to the container. The pressure cells are interconnected by a gas control assembly including a thermally activated pressure relief device, a manual safety shut-off valve, and means for connecting the fuel storage system to a vehicle power source and a refueling adapter. The gas control assembly is enclosed by a protective cover attached to the container. The system is attached to the vehicle with straps to enable the chassis to deform as intended in a high-speed collision.

  6. Compressed sensing for distributed systems

    CERN Document Server

    Coluccia, Giulio; Magli, Enrico

    2015-01-01

    This book presents a survey of the state-of-the art in the exciting and timely topic of compressed sensing for distributed systems. It has to be noted that, while compressed sensing has been studied for some time now, its distributed applications are relatively new. Remarkably, such applications are ideally suited to exploit all the benefits that compressed sensing can provide. The objective of this book is to provide the reader with a comprehensive survey of this topic, from the basic concepts to different classes of centralized and distributed reconstruction algorithms, as well as a comparison of these techniques. This book collects different contributions on these aspects. It presents the underlying theory in a complete and unified way for the first time, presenting various signal models and their use cases. It contains a theoretical part collecting latest results in rate-distortion analysis of distributed compressed sensing, as well as practical implementations of algorithms obtaining performance close to...

  7. Nonlinear compression of optical solitons

    Indian Academy of Sciences (India)

    linear pulse propagation is the nonlinear Schrödinger (NLS) equation [1]. There are ... Optical pulse compression finds important applications in optical fibres. The pulse com ..... to thank CSIR, New Delhi for financial support in the form of SRF.

  8. Gestational ultrasonography and Dopplerfluxometry in capuchin monkeys (Sapajus apella) zoometric.

    Science.gov (United States)

    Miranda, S A; Leão, D L; Oliveira, K G; Sodré, I S; Domingues, S F S

    2018-03-01

    The objectives of the current study were as follows: 1) to evaluate blood flow in the uterine (UA) and umbilical (Uma) arteries in pregnant capuchin monkeys by measuring the resistive index (RI) and pulsatility index (PI); 2) to determine the presence or absence of the early diastolic notch and diastolic flow in the UA and Uma flow waveforms, respectively; 3) to perform conceptus echobiometry for fetal growth assessment during pregnancy; 4) to describe the moment that the fetal organs were initially observed; and 5) to determine when the diagnosis of fetal gender is possible. Seven healthy, sexually mature female Sapajus apella were examined in Weeks -20 to -1 before whelping (whelping Week 0). Triplex Doppler was used to assess the blood flow and fetal heart rate, and B-mode ultrasonography was used to assess the fetal organs and conceptus measurements, including the gestational sac latero-lateral longitudinal (LLL) and latero-lateral transversal (LLT), the crown rump length (CRL), biparietal diameter (BPD), occipito-frontal diameter (OFD), head circumference (HC), abdominal circumference (AC), femur length (FL) and fetal organ. All the pregnancies ended with a normal whelping and the birth of a live newborn. Prior to whelping, all conceptus dimensions increased significantly, whereas the RI and PI of both the UA and Uma decreased significantly. For the UA, the RI and PI were (mean ± SEM) 0.835 ± 0.017 and 2.157 ± 0.129, 0.808 ± 0.008 and 1.920 ± 0.041, and 0.761 ± 0.006 and 1.759 ± 0.036 on periods -3, -2 and -1, respectively. For the Uma, the RI and PI were 0.97 ± 0.01 and 2.50 ± 0.02 at Week -17 and were 0.64 ± 0.02 and 0.98 ± 0.04 at Week -1, respectively. The complete disappearance of the early diastolic notch in the UA, and the complete appearance of diastolic flow in the Uma occurred on Week -1 and Week -11, respectively. Linear regression analyses regarding the relationship of the weeks before whelping (WBW) with the

  9. Improvement of diagnostic accuracy, and clinical evaluation of computed tomography and ultrasonography for deep seated cancers

    International Nuclear Information System (INIS)

    Arimizu, Noboru

    1980-01-01

    Cancers of the liver, gallbladder, and pancreas which were difficult to be detected at an early stage were studied. Diagnostic accuracy of CT and ultrasonography for vesectable small cancers was investigated by the project team and coworkers. Only a few cases of hepatocellular carcinoma, cancer of the common bile duct, and cancer of the pancreas head, with the maximum diameter of 1 - 2 cm, were able to be diagnosed by CT. There seemed to be more false negative cases with small cancers of that size. The limit of the size which could be detected by CT was thought to be 2 - 3 cm. Similar results were obtained by ultrasonography. Cancer of the pancreas body with the maximum diameter of less than 3.5 cm could not be detected by both CT and ultrasonography. Diagnostic accuracy of CT for liver cancer was improved by selective intraarterial injection of contrast medium. Improvement of the quality of ultrasonograms was achieved through this study. Merits and demerits of CT and ultrasonography were also compared. (Tsunoda, M.)

  10. The Role of Ultrasonography in In-vitro Fertilization And Embryo ...

    African Journals Online (AJOL)

    Randomized controlled trials show that ultrasoundguided transfer techniques have better outcomes than the clinical touch technique in terms of on-going pregnancies and clinical pregnancies. Ultrasonography is now the key instrument for diagnosing and monitoring pregnancy following embryo transfer, biochemical ...

  11. Application of Intraoperative Ultrasonography for Guiding Microneurosurgical Resection of Small Subcortical Lesions

    International Nuclear Information System (INIS)

    Wang, Jia; Duan, Yun You; Liu, Xi; Wang, Yu; Gao, Guo Dong; Qin, Huai Zhou; Wang, Liang

    2011-01-01

    We wanted to evaluate the clinical value of intraoperative ultrasonography for real-time guidance when performing microneurosurgical resection of small subcortical lesions. Fifty-two patients with small subcortical lesions were involved in this study. The pathological diagnoses were cavernous hemangioma in 25 cases, cerebral glioma in eight cases, abscess in eight cases, small inflammatory lesion in five cases, brain parasite infection in four cases and the presence of an intracranial foreign body in two cases. An ultrasonic probe was sterilized and lightly placed on the surface of the brain during the operation. The location, extent, characteristics and adjacent tissue of the lesion were observed by high frequency ultrasonography during the operation. All the lesions were located in the cortex and their mean size was 1.3 ± 0.2 cm. Intraoperative ultrasonography accurately located all the small subcortical lesions, and so the neurosurgeon could provide appropriate treatment. Different lesion pathologies presented with different ultrasonic appearances. Cavernous hemangioma exhibited irregular shapes with distinct margins and it was mildly hyperechoic or hyperechoic. The majority of the cerebral gliomas displayed irregular shapes with indistinct margins, and they often showed cystic and solid mixed echoes. Postoperative imaging identified that the lesions had completely disappeared, and the original symptoms of all the patients were significantly alleviated. Intraoperative ultrasonography can help accurately locate small subcortical lesions and it is helpful for selecting the proper approach and guiding thorough resection of these lesions.

  12. Application of Intraoperative Ultrasonography for Guiding Microneurosurgical Resection of Small Subcortical Lesions

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Jia; Duan, Yun You; Liu, Xi; Wang, Yu; Gao, Guo Dong; Qin, Huai Zhou; Wang, Liang [Tangdu Hospital of the Fourth Military Medicine University, Xi an (China)

    2011-10-15

    We wanted to evaluate the clinical value of intraoperative ultrasonography for real-time guidance when performing microneurosurgical resection of small subcortical lesions. Fifty-two patients with small subcortical lesions were involved in this study. The pathological diagnoses were cavernous hemangioma in 25 cases, cerebral glioma in eight cases, abscess in eight cases, small inflammatory lesion in five cases, brain parasite infection in four cases and the presence of an intracranial foreign body in two cases. An ultrasonic probe was sterilized and lightly placed on the surface of the brain during the operation. The location, extent, characteristics and adjacent tissue of the lesion were observed by high frequency ultrasonography during the operation. All the lesions were located in the cortex and their mean size was 1.3 {+-} 0.2 cm. Intraoperative ultrasonography accurately located all the small subcortical lesions, and so the neurosurgeon could provide appropriate treatment. Different lesion pathologies presented with different ultrasonic appearances. Cavernous hemangioma exhibited irregular shapes with distinct margins and it was mildly hyperechoic or hyperechoic. The majority of the cerebral gliomas displayed irregular shapes with indistinct margins, and they often showed cystic and solid mixed echoes. Postoperative imaging identified that the lesions had completely disappeared, and the original symptoms of all the patients were significantly alleviated. Intraoperative ultrasonography can help accurately locate small subcortical lesions and it is helpful for selecting the proper approach and guiding thorough resection of these lesions.

  13. Improvement of diagnostic accuracy, and clinical evaluation of computed tomography and ultrasonography for deep seated cancers

    Energy Technology Data Exchange (ETDEWEB)

    Arimizu, N [Chiba Univ. (Japan). School of Medicine

    1980-06-01

    Cancers of the liver, gallbladder, and pancreas which were difficult to be detected at an early stage were studied. Diagnostic accuracy of CT and ultrasonography for resectable small cancers was investigated by the project team and co-workers. Only a few cases of hepatocellular carcinoma, cancer of the common bile duct, and cancer of the pancreas head, with the maximum diameter of 1 - 2 cm, were able to be diagnosed by CT. There seemed to be more false negative cases with small cancers of that size. The limit of the size which could be detected by CT was thought to be 2 - 3 cm. Similar results were obtained by ultrasonography. Cancer of the pancreas body with the maximum diameter of less than 3.5 cm could not be detected by both CT and ultrasonography. Diagnostic accuracy of CT for liver cancer was improved by selective intraarterial injection of contrast medium. Improvement of the quality of ultrasonograms was achieved through this study. Merits and demerits of CT and ultrasonography were also compared.

  14. Assessment of Oropharyngeal Dysphagia in Patients With Parkinson Disease: Use of Ultrasonography.

    Science.gov (United States)

    Oh, Eun Hyun; Seo, Jin Seok; Kang, Hyo Jung

    2016-04-01

    To compare tongue thickness, the shortest hyoid-thyroid approximation (distance between the hyoid bone and thyroid cartilage), and the time interval between the initiation of tongue movement and the time of the shortest hyoid-thyroid approximation, by using ultrasonography in healthy controls and patients with Parkinson disease (PD). Healthy controls and PD patients with dysphagia were compared. Ultrasonography was performed 3 times for the evaluation of tongue thickness, the shortest hyoid-thyroid approximation, and the time between the initiation of tongue movement and the shortest hyoid-thyroid approximation. A total of 24 healthy controls and 24 PD patients with dysphagia were enrolled. No significant differences were demonstrated between the two groups for the shortest hyoid-thyroid approximation (controls, 1.19±0.34 cm; PD patients, 1.37±0.5 cm; p=0.15) and tongue thickness (controls, 4.42±0.46 cm; PD patients, 4.27±0.51 cm; p=0.3). In contrast, the time to the shortest hyoid-thyroid approximation was significantly different between the two groups (controls, 1.53±0.87 ms; PD patients, 2.4±1.4 ms, p=0.048). Ultrasonography can be useful in evaluating dysphagia in patients with PD by direct visualization and measurement of the hyoid bone. Moreover, ultrasonography might contribute to a greater understanding of the pathophysiology of dysphagia in PD.

  15. Follow-up of renal and mesenteric artery revascularization with duplex ultrasonography

    Science.gov (United States)

    Taylor, David C.; Houston, Gordon T.M.; Anderson, Caroline; Jameson, Margot; Popatia, Shelley

    1996-01-01

    Objective To evaluate the long-term anatomic results of renal revascularization procedures using duplex ultrasonography. Design A case series. Setting A university-affiliated hospital. Patients Twenty-five patients who had undergone renal percutaneous transluminal angioplasty (PTA) (18 arteries), renal bypass (10 arteries) and mesenteric bypass (6 arteries). The mean follow-up was 22 months (range from 3 to 48 months) for those who underwent renal PTA, 23 months (range from 1.5 to 70 months) for those who underwent renal bypass and 34 months (range from 8 to 144 months) for those who underwent mesenteric bypass. Main Outcome Measures Patency rates for the three procedures as assessed by duplex ultrasonography. Results Duplex ultrasonography demonstrated patency without stenosis after renal and mesenteric artery revascularization in 14 arteries subjected to renal PTA, 9 arteries subjected to renal bypass and 6 arteries subjected to mesenteric bypass. Three arteries that had renal PTA had recurrent vessel stenosis and one had occlusion. One artery that had renal bypass showed occlusion. Conclusions Renal PTA, renal bypass and mesenteric bypass are durable procedures at 2 years of follow-up, and duplex ultrasonography is a valuable method for assessing the patency of arteries after renal and mesenteric revascularization. PMID:8599785

  16. Ultrasonography of the larynx for diagnosis of the vocal folds mobility impairment

    Directory of Open Access Journals (Sweden)

    Petr S. Vetshev

    2017-03-01

    Full Text Available Purpose. To study a possibility of performance and diagnostic accuracy of ultrasonography (US of a larynx in identification of motility disorders of VF (vocal folds in comparison with the laryngoscope which is traditionally applied for this purpose. Materials and methods. According to the objectives of the study, two patient groups were formed. In first group of patients (n = 466 we studied acceptability of ultrasonografy to discriminate various laryngeal structures. In second group of patient (n = 432 we evaluated the diagnostic accuracy of ultrasonography in point of detection of vocal muscles paresis. Results. Laryngeal structures were available to examination by ultrasound (without taking in account age and sex in 92.7% of patients. Two patterns have been identified in the course of this part of the study: deterioration of visibility of the vocal folds with increasing patient age and better visibility of the vocal folds in women than in men. According to the comparative analysis, ultrasonography accuracy rate (in those patients who had had clearly visible vocal folds during ultrasonography did not differ from that during videolaryngoscopy. Conclusion. During the conducted research it was found that the US of the larynx is an effective and perspective method for detection of a paresis of VF with sensitivity and specificity 93,55% and 100% respectively. Among those patients who' VF are available to ultrasound evaluation the accuracy of method is comparable with a videolaryngoscopy and can be used with success in daily work of units of endocrine surgery.

  17. Use of musculoskeletal ultrasonography in the diagnosis of pes anserine tendinitis: a case report.

    Science.gov (United States)

    Valley, V T; Shermer, C D

    2001-01-01

    A 45-year-old woman presented to the Emergency Department with a chief complaint of acute, nontraumatic medial knee pain. Musculoskeletal ultrasonography was performed, and the diagnosis of pes anserine tendinitis was elucidated. A discussion of this clinical entity, the characteristic ultrasonographic findings, and therapy follow in this case report.

  18. Laparoscopic ultrasonography--a method for staging of upper gastrointestinal cancer

    DEFF Research Database (Denmark)

    Durup Scheel-Hincke, J; Mortensen, M B; Pless, T

    1999-01-01

    Laparoscopic ultrasonography (LUS) is a method that can be useful in the staging of upper gastrointestinal cancer. Dedicated transducers are available, and preliminary studies have proposed indications for the use of LUS staging of hepatic, esophageal, gastric, and pancreatic cancer disease. In t...

  19. Ultrasonography, computed tomography, and cholescintigraphy in suspected obstructive jaundice--a prospective comparative study

    DEFF Research Database (Denmark)

    Matzen, P; Malchow-Møller, A; Brun, B

    1983-01-01

    In order to compare their capacity to visualize the bile ducts, ultrasonography, computed tomography, and cholescintigraphy were performed in 56 consecutive jaundiced patients in whom extrahepatic cholestasis was clinically suspected. The predictions as to the patency of the large bill ducts were...

  20. Ultrasonography and magnetic resonance imaging in early rheumatoid arthritis: recent advances

    DEFF Research Database (Denmark)

    Østergaard, Mikkel; Døhn, Uffe M; Ejbjerg, Bo J

    2006-01-01

    Efficient methods for diagnosis, monitoring, and prognostication are essential in early rheumatoid arthritis. Data on the value of ultrasonography and MRI are accumulating rapidly, fueling their increasing use in early rheumatoid arthritis. This review focuses on recent advances in the clinical...

  1. Diagnosis of fibroadenoma and breast cancer: ultrasonography vs. X-ray mammography

    Energy Technology Data Exchange (ETDEWEB)

    Song, Jong Gi; Im, Jung gi; Choi, Byung Ihn; Kim, Choo Wan [Seoul National University College of Medicine, Seoul (Korea, Republic of)

    1993-12-15

    To evaluate the clinical value of ultrasonography in the diagnosis of fibroadenoma and carcinoma as compared with mammography, we performed a blind retrospective analysis of 85 sonograms and 40 mammograms of 85 breasts that were proved pathologically to have diseases. The lesions included 30 ductal carcinomas, 29 fibroadenomas, 14mammary dysplasias, 2 medullary carcinomas, 1 intraductal papillary carcinoma, and 9 cases of other pathology. The sonograms were reviewed in regards to the border, shape and internal echo pattern of the lesion and the shadows from the margin of the lesion. The mammograms were reviewed in regards to the parenchymal pattern, shape, margin,and calcification of the lesion. The accuracy, sensitivity, and specificity of mammography and ultrasonography in the diagnosis of fibroadenoma were 77%/92%, 40%/93%, and 100%/92%, respectively. The accuracy, sensitivity, and specificity of mammography and ultrasonography in the diagnosis of carcinoma were 85%/85%, 76%/82%, and 91%/86%,respectively. Ultrasonography is more accurate and more sensitive than mammography in the diagnosis offibroadenoma, but not in the diagnosis of carcinoma

  2. Is salivary gland ultrasonography a useful tool in Sjogren's syndrome? A systematic review

    NARCIS (Netherlands)

    Jousse-Joulin, Sandrine; Milic, Vera; Jonsson, Malin V.; Plagou, Athena; Theander, Elke; Luciano, Nicoletta; Rachele, Pascale; Baldini, Chiara; Bootsma, Hendrika; Vissink, Arjan; Hocevar, Alojzija; De Vita, Salvatore; Tzioufas, Athanasios G.; Alavi, Zarin; Bowman, Simon J.; Devauchelle-Pensec, Valerie

    Objective. Ultrasonography (US) is a sensitive tool in the diagnosis of major salivary gland abnormalities in primary Sjogren's syndrome (pSS). The aim of this systematic review was to assess the metric properties of this technique. Methods. PUBMED and EMBASE databases were searched. All

  3. Prediction of late failure after medical abortion from serial beta-hCG measurements and ultrasonography

    DEFF Research Database (Denmark)

    Rørbye, C; Nørgaard, M; Nilas, Lisbeth

    2004-01-01

    BACKGROUND: Surgical treatment of failed medical abortion may be performed several weeks after initiation of the abortion. There are no recognized methods for early identification of these late failures. We assessed the prognostic values of beta-hCG and ultrasonography in predicting late failure ...

  4. Dynamic Contrast-Enhanced Magnetic Resonance Enterography and Dynamic Contrast-Enhanced Ultrasonography in Crohn's Disease

    DEFF Research Database (Denmark)

    Wilkens, Rune; Peters, David A; Nielsen, Agnete Hedemann

    2017-01-01

    Purpose e Cross-sectional imaging methods are important for objective evaluationof small intestinal inflammationinCrohn'sdisease(CD).The primary aim was to compare relative parameters of intestinal perfusion between contrast-enhanced ultrasonography (CEUS) and dynamic contrast-enhanced magnetic...

  5. Ultrasonography and magnetic resonance imaging in the diagnosis of Morton's neuroma.

    Science.gov (United States)

    Fazal, Muhammad Ali; Khan, Ishrat; Thomas, Cherian

    2012-01-01

    Magnetic resonance imaging (MRI) and ultrasonography are used widely for the diagnosis of Morton's neuroma. The aim of this study was to assess the accuracy of these two modalities as diagnostic tools in Morton's neuroma. Fifty feet of 47 consecutive patients (39 women and 8 men; mean age, 46 years; age range, 36-64 years) who presented between January 1, 2005, and June 30, 2008, were included in the study. Twenty-five feet were investigated with ultrasonography and 25 with MRI. Morton's neuroma was confirmed surgically and histologically in all of the patients. A Student unpaired t test was applied. Twenty-two MRIs were diagnostic (sensitivity, 88%). Three patients with negative MRI findings underwent ultrasonography and were found to have a neuroma smaller than 5 mm. Twenty-four ultrasound scans demonstrated the neuroma (sensitivity, 96%), with five neuromas being smaller than 5 mm. Ultrasonography has a slightly higher sensitivity in the diagnosis of Morton's neuroma, particularly of neuromas smaller than 5 mm, and should be the preferred imaging modality in suspected cases, and MRI should be reserved for cases with equivocal diagnosis.

  6. Diagnosis of fibroadenoma and breast cancer: ultrasonography vs. X-ray mammography

    International Nuclear Information System (INIS)

    Song, Jong Gi; Im, Jung gi; Choi, Byung Ihn; Kim, Choo Wan

    1993-01-01

    To evaluate the clinical value of ultrasonography in the diagnosis of fibroadenoma and carcinoma as compared with mammography, we performed a blind retrospective analysis of 85 sonograms and 40 mammograms of 85 breasts that were proved pathologically to have diseases. The lesions included 30 ductal carcinomas, 29 fibroadenomas, 14mammary dysplasias, 2 medullary carcinomas, 1 intraductal papillary carcinoma, and 9 cases of other pathology. The sonograms were reviewed in regards to the border, shape and internal echo pattern of the lesion and the shadows from the margin of the lesion. The mammograms were reviewed in regards to the parenchymal pattern, shape, margin,and calcification of the lesion. The accuracy, sensitivity, and specificity of mammography and ultrasonography in the diagnosis of fibroadenoma were 77%/92%, 40%/93%, and 100%/92%, respectively. The accuracy, sensitivity, and specificity of mammography and ultrasonography in the diagnosis of carcinoma were 85%/85%, 76%/82%, and 91%/86%,respectively. Ultrasonography is more accurate and more sensitive than mammography in the diagnosis offibroadenoma, but not in the diagnosis of carcinoma

  7. Ability of subtraction and dynamic MR imaging to detect breast tumors. Comparison with ultrasonography and mammography

    International Nuclear Information System (INIS)

    Terao, Eri; Takeuchi, Hiroaki; Iwamura, Akira; Murakami, Yoshitaka; Harada, Junta; Tada, Shinpei

    1994-01-01

    We evaluated the ability of subtraction and dynamic MR imaging to accurately detect breast tumors. Sixty-five breast carcinomas and 24 fibroadenomas were examined by an SE pulse sequence using a 0.2 Tesla unit. Subtraction MR images were obtained every minute during dynamic study with Gd-DTPA. Almost all breast tumors were seen as very bright masses, and the margin of the mass was clearly demonstrated on subtraction MR images. Breast carcinomas and fibroadenomas showed characteristic time-intensity curves on dynamic study. Time-intensity curves of the early peak type and plateau type were seen in 97% of breast carcinomas, while the gradually increasing type was seen in 92% of fibroadenomas. The detectability of breast carcinoma was 98% by MRI, 98% by ultrasonography, and 87% by mammography. That of fibroadenoma was 95% by MRI, 91% by ultrasonography and 60% by mammography. Sensitivity and specificity for breast carcinoma were 98% and 92% for MRI and 97% and 71% for ultrasonography. For fibroadenoma, they were 96% and 98% for MRI and 89% and 92% for ultrasonography. (author)

  8. Ability of subtraction and dynamic MR imaging to detect breast tumors. Comparison with ultrasonography and mammography

    Energy Technology Data Exchange (ETDEWEB)

    Terao, Eri; Takeuchi, Hiroaki; Iwamura, Akira; Murakami, Yoshitaka; Harada, Junta; Tada, Shinpei (Jikei Univ., Tokyo (Japan). School of Medicine)

    1994-09-01

    We evaluated the ability of subtraction and dynamic MR imaging to accurately detect breast tumors. Sixty-five breast carcinomas and 24 fibroadenomas were examined by an SE pulse sequence using a 0.2 Tesla unit. Subtraction MR images were obtained every minute during dynamic study with Gd-DTPA. Almost all breast tumors were seen as very bright masses, and the margin of the mass was clearly demonstrated on subtraction MR images. Breast carcinomas and fibroadenomas showed characteristic time-intensity curves on dynamic study. Time-intensity curves of the early peak type and plateau type were seen in 97% of breast carcinomas, while the gradually increasing type was seen in 92% of fibroadenomas. The detectability of breast carcinoma was 98% by MRI, 98% by ultrasonography, and 87% by mammography. That of fibroadenoma was 95% by MRI, 91% by ultrasonography and 60% by mammography. Sensitivity and specificity for breast carcinoma were 98% and 92% for MRI and 97% and 71% for ultrasonography. For fibroadenoma, they were 96% and 98% for MRI and 89% and 92% for ultrasonography. (author).

  9. Diagnostic value of liver scintigraphy, computed tomography and ultrasonography of fatal hepatitis

    International Nuclear Information System (INIS)

    Komori, Hideshi; Hirasa, Masahiro; Ibuki, Yasuyoshi

    1983-01-01

    The purpose of this study was investigate the diagnostic value of liver scintigraphy, computed tomography (CT) and ultrasonography in acute hepatic failure, subacute hepatitis and acute hepatitis. By scintigraphy low uptake in the liver and high uptake in the spleen and bone marrow were observed in hepatic failure. However, uneven liver edge and heterogenous RI destribution were not corresponded to massive necrosis. In fulminant hepatitis, liver size and other findings were variable in patient by patient. But in subacute hepatitis, the findings were typical. The finding of left lobe swelling was observed in a half of patients with acute hepatic failure based on chronic hepatitis. Localized low density area by the CT was detected in most of the cases of subacute hepatitis, and acute hepatitis with submassive hepatic necrosis. But in fulminant hepatitis, that was rare. In these cases, irregular and strong lesion was also obsurved by ultrasonography. These findings by the CT and ultrasonography were corresponded to massive necrosis histrogically ultrasonography revealed narrowing of hepatic vein in fatal hepatitis. Localized low density area by the CT in subacute hepatitis was shown surrounding hepatic vein. We conclude that development of massine hepatic necrosis concern to secondary hepatic ischemia. (author)

  10. Liver metastases: Sulphur hexafluoride-enhanced ultrasonography for lesion detection: a systematic review

    NARCIS (Netherlands)

    Cabassa, Paolo; Bipat, Shandra; Longaretti, Laura; Morone, Mario; Maroldi, Roberto

    2010-01-01

    This is a systematic review to evaluate the accuracy of contrast-enhanced ultrasonography (CEUS) performed with "SonoVue" (sulphur hexafluoride) in the detection of hepatic metastases. The MEDLINE, EMBASE and COCHRANE Databases were searched, regardless of language, for relevant articles published

  11. Portal blood flow volume measurement in schistosomal patients: evaluation of Doppler ultrasonography reproducibility

    International Nuclear Information System (INIS)

    Leao, Alberto Ribeiro de Souza; Santos, Jose Eduardo Mourao; Moulin, Danilo Sales; Shigueoka, David Carlos; D'Ippolito, Giuseppe; Colleoni, Ramiro

    2008-01-01

    Objective: To evaluate the reproducibility of Doppler ultrasonography in the measurement of portal blood flow volume in schistosomal patients. Materials and methods: Prospective, transversal, observational and self-paired study evaluating 21 patients with hepatosplenic schistosomiasis submitted to Doppler ultrasonography performed by three independent observers for measurement of portal blood flow. Pairwise interobserver agreement was calculated by means of the intraclass correlation coefficient, paired t-test and Pearson's correlation coefficient. Results: Interobserver agreement was excellent. Intraclass correlation ranged from 80.6% to 93.0% (IC at 95% [65.3% ; 95.8%]), with the Pearson's correlation coefficient ranging between 81.6% and 92.7% with no statistically significant interobserver difference regarding the mean portal blood flow volume measured by Doppler ultrasonography (p = 0.954 / 0.758 / 0.749). Conclusion: Doppler ultrasonography has demonstrated to be a reliable method for measuring the portal blood flow volume in patients with portal hypertension secondary to schistosomiasis, with a good interobserver agreement. (author)

  12. Ultrasonography to quantify hepatic fat content : Validation by H-1 Magnetic Resonance Spectroscopy

    NARCIS (Netherlands)

    Edens, M.A.; van Ooijen, P.M.A.; Post, W.J.; Haagmans, M.J.F.; Kristanto, W.; Sijens, P.E.; van der Jagt, E.J.; Stolk, R.P.

    2009-01-01

    An abundance of fat stored within the liver, or steatosis, is the beginning of a broad hepatological spectrum, usually referred to as fatty liver disease (FLD). For studies on FLD, quantitative hepatic fat ultrasonography would be an appealing study modality. Objective of this study was to develop a

  13. Ultrasonography, scintigraphy and computerized tomography in the investigation of the biliary tract

    International Nuclear Information System (INIS)

    Elie, G.; Drouillard, J.; Leccia, F.; Bergeron, J.-L.; Ducassou, D.; Tarvernier, J.

    1981-01-01

    New methods of investigation of the gallbladder and jaundice, without discomfort for the patients, have changed the usual algorythms. The main investigation is ultrasonography, without irradiation, not expensive, it is the best way to appreciate the dilatation of the biliary tract [fr

  14. Imaging in early rheumatoid arthritis: roles of magnetic resonance imaging, ultrasonography, conventional radiography and computed tomography

    DEFF Research Database (Denmark)

    Østergaard, Mikkel; Ejbjerg, Bo; Szkudlarek, Marcin

    2005-01-01

    Efficient methods for diagnosis, monitoring and prognostication are essential in early rheumatoid arthritis (RA). While conventional X-rays only visualize the late signs of preceding disease activity, there is evidence for magnetic resonance imaging (MRI) and ultrasonography being highly sensitiv...

  15. Serial cranial ultrasonography or early MRI for detecting preterm brain injury?

    NARCIS (Netherlands)

    Plaisier, Annemarie; Raets, Marlou M A; Ecury-Goossen, Ginette M; Govaert, Paul; Feijen-Roon, Monique; Reiss, Irwin K M; Smit, Liesbeth S; Lequin, Maarten H; Dudink, Jeroen

    OBJECTIVE: To investigate detection ability and feasibility of serial cranial ultrasonography (CUS) and early MRI in preterm brain injury. DESIGN: Prospective cohort study. SETTING: Level III neonatal intensive care unit. PATIENTS: 307 infants, born below 29 weeks of gestation. METHODS: Serial CUS

  16. Portal blood flow volume measurement in schistosomal patients: evaluation of Doppler ultrasonography reproducibility

    Energy Technology Data Exchange (ETDEWEB)

    Leao, Alberto Ribeiro de Souza; Santos, Jose Eduardo Mourao; Moulin, Danilo Sales; Shigueoka, David Carlos; D' Ippolito, Giuseppe [Universidade Federal de Sao Paulo (UNIFESP/EPM), SP (Brazil). Escola Paulista de Medicina. Dept. de Diagnostico por Imagem]. E-mail: ar.leao@uol.com.br; Colleoni, Ramiro [Universidade Federal de Sao Paulo (UNIFESP/EPM), SP (Brazil). Escola Paulista de Medicina. Dept. de Gastroenterologia

    2008-09-15

    Objective: To evaluate the reproducibility of Doppler ultrasonography in the measurement of portal blood flow volume in schistosomal patients. Materials and methods: Prospective, transversal, observational and self-paired study evaluating 21 patients with hepatosplenic schistosomiasis submitted to Doppler ultrasonography performed by three independent observers for measurement of portal blood flow. Pairwise interobserver agreement was calculated by means of the intraclass correlation coefficient, paired t-test and Pearson's correlation coefficient. Results: Interobserver agreement was excellent. Intraclass correlation ranged from 80.6% to 93.0% (IC at 95% [65.3% ; 95.8%]), with the Pearson's correlation coefficient ranging between 81.6% and 92.7% with no statistically significant interobserver difference regarding the mean portal blood flow volume measured by Doppler ultrasonography (p = 0.954 / 0.758 / 0.749). Conclusion: Doppler ultrasonography has demonstrated to be a reliable method for measuring the portal blood flow volume in patients with portal hypertension secondary to schistosomiasis, with a good interobserver agreement. (author)

  17. Implementation of laparoscopic splenectomy in children and the incidence of portal vein thrombosis diagnosed by ultrasonography

    NARCIS (Netherlands)

    Oomen, Matthijs W. N.; Bakx, Roel; van Minden, Minke; van Rijn, Rick R.; Peters, Marjolein; Heij, Hugo A.

    2013-01-01

    The aim of this study is to evaluate if symptomatic or asymptomatic PVT, as diagnosed with ultrasonography (US), occurs more often in children after the introduction and implementation of LS compared to open splenectomy. A retrospective cohort of 76 splenectomized patients for benign hematological

  18. Use of ultrasonography to identify late-stage maturity in rainbow trout Oncorhynchus mykiss

    Science.gov (United States)

    Morphometric measurements by ultrasonography has been used to determine gonad and follicle size in many species of fish for purposes of identifying sex and estimating stage of maturation. We have been using a portable ultrasound system (SonoSite MicroMaxx, L25e/13-6 MHz transducer) to identify fem...

  19. Ultrasonography of occipital arteries to diagnose giant cell arteritis: a case series and literature review.

    Science.gov (United States)

    Pinnell, Jonathan; Tiivas, Carl; Perkins, Phillip; Blake, Tim; Saravana, Shanmugam; Dubey, Shirish

    2018-02-01

    We describe four cases of giant cell arteritis (GCA) that presented with occipital headache in the last 6 months. Typical ultrasound features of GCA were found in the occipital arteries which helped to confirm the diagnosis. One patient had already suffered significant visual loss by the time the diagnosis was made, reflecting the similarity in prognosis to the more typical GCA patients. These cases prompted a review of the literature to evaluate the evidence regarding the use of occipital artery ultrasonography in the investigation of GCA. We searched PubMed, Google Scholar and Web of Science and identified 17 papers but only four of these were relevant studies. The studies available show that typical features of GCA can be detected in the occipital arteries using ultrasonography. They also suggest that ultrasonography can detect changes in the occipital arteries when temporal arteries are not involved. However, occipital artery abnormalities were less common than temporal artery abnormalities in GCA. We advocate maintaining a high index of suspicion for GCA in patients presenting with atypical features, such as occipital headache. Ultrasonography has a vital role to play in the diagnosis of these patients. We recommend priority imaging of the affected area to facilitate prompt and accurate diagnosis of GCA, especially when atypical vessels are involved.

  20. Guiding histological assessment of uterine lesions using 3D in vitro ultrasonography and stereotaxis

    DEFF Research Database (Denmark)

    Vandermeulen, Liselore; Cornelis, Ann; Rasmussen, Christina Kjærgaard

    2017-01-01

    , the uterus was re-evaluated by 3D in vitro ultrasonography and in vitro gel instillation sonography (iGIS). The lesion of interest was pinpointed by inserting an intramuscular injection needle using a free-hand 2D-ultrasound guided technique to focus the macroscopic and the microscopic examination...

  1. Brain ultrasonography findings in neonates with exposure to cocaine during pregnancy

    NARCIS (Netherlands)

    van Huis, M.; van Kempen, A.A.M.W.; Peelen, M.; Timmers, M.; Boer, K.; Smit, B.J.; van Rijn, R.R.

    2009-01-01

    BACKGROUND: Cocaine exposure during pregnancy has been reported to have detrimental effects on the fetus. OBJECTIVE: To describe the findings on cranial ultrasonography (CUS) as part of a neonatal screening programme for exposed neonates. MATERIALS AND METHODS: The study was a semiprospective

  2. Current relevance of cervical ultrasonography in staging cancer of the esophagus and gastroesophageal junction

    NARCIS (Netherlands)

    Schreurs, Liesbeth; Verhoef, C.C.; van der Jagt, E.J.; van Dam, G.M.; Groen, H.; Plukker, J.T.

    Purpose: To evaluate the value of external ultrasonography (US) of the neck in current dedicated preoperative staging of patients with cancer of the esophagus and gastroesophageal junction (GEJ). Materials and methods: We analyzed 180 consecutive patients (154 men, 26 women, and mean age 63 (38-84)

  3. Diagnosis of ovarian tumors by ultrasonography and x-ray CT

    International Nuclear Information System (INIS)

    Watanabe, Hiromu

    1986-01-01

    A drawback in ultrasonography, an indispensable technique in imaging ovarian malignancies, is that it sometimes shows false positive for benign tumors including dermoid cyst and ovarian endometriosis. To overcome this, the concurrent use of X-Ray CT seems warrantable and this led us to carry out the study summarized below. CT was carried out on 268 of 322 ovarian disease cases which had undergone ultrasonography. The results obtained were as follows. Sensitivity of ultrasonography and CT in ovarian malignancies were 82 % and 88 % respectively. Of the cases subjected to both techniques, those who were deemed false positive were 39 in ultrasonography and 12 in CT. Ultrasonographic imagings of dermoid cyst and ovarian endometriosis were classified on the basis of their patterns. The results obtained revealed that those in which it was difficult to discriminate the image from ovarian malignancy were types V and VI in dermoid cyst and type III-C in ovarian endometriosis. In both dermoid cyst and ovarian endometriosis, nearly a 100 % accuracy rate was obtainable with CT for diagnosis of benign tumors. This strongly suggested that concurrent use of CT was required, in diagnosing ovarian diseases with the V or VI and III-C patterns referred to above. (author)

  4. Screening Performance Characteristic of Ultrasonography and Radiography in Detection of Pleural Effusion; a Meta-Analysis.

    Science.gov (United States)

    Yousefifard, Mahmoud; Baikpour, Masoud; Ghelichkhani, Parisa; Asady, Hadi; Shahsavari Nia, Kavous; Moghadas Jafari, Ali; Hosseini, Mostafa; Safari, Saeed

    2016-01-01

    The role of ultrasonography in detection of pleural effusion has long been a subject of interest but controversial results have been reported. Accordingly, this study aims to conduct a systematic review of the available literature on diagnostic value of ultrasonography and radiography in detection of pleural effusion through a meta-analytic approach. An extended search was done in databases of Medline, EMBASE, ISI Web of Knowledge, Scopus, Cochrane Library, and ProQuest. Two reviewers independently extracted the data and assessed the quality of the articles. Meta-analysis was performed using a mixed-effects binary regression model. Finally, subgroup analysis was carried out in order to find the sources of heterogeneity between the included studies. 12 studies were included in this meta-analysis (1554 subjects, 58.6% male). Pooled sensitivity of ultrasonography in detection of pleural effusion was 0.94 (95% CI: 0.88-0.97; I2= 84.23, pultrasonography was found to be higher when the procedure was carried out by an intensivist or a radiologist using 5-10 MHz transducers. Chest ultrasonography, as a screening tool, has a higher diagnostic accuracy in identification of plural effusion compared to radiography. The sensitivity of this imaging modality was found to be higher when performed by a radiologist or an intensivist and using 5-10MHz probes.

  5. QUANTITATIVE MUSCLE ULTRASONOGRAPHY IN THE FOLLOW-UP OF JUVENILE DERMATOMYOSITIS

    NARCIS (Netherlands)

    Habers, G. Esther A.; van Brussel, Marco; Bhansing, Kavish J.; Hoppenreijs, Esther P.; Janssen, Anjo J. W. M.; van Royen-Kerkhof, Annet; Pillen, Sigrid

    2015-01-01

    Introduction: We explored the use of quantitative muscle ultrasonography (QMUS) for follow-up of juvenile dermatomyositis (JDM). Methods: Seven JDM patients were evaluated at diagnosis and 1, 3, 6, 12, and 24 months using the Childhood Myositis Assessment Scale (CMAS) and QMUS. Muscle thickness (MT)

  6. Ultrasonography in arthritis of the knee. A comparison with MR imaging

    DEFF Research Database (Denmark)

    Østergaard, Mikkel; Court-Payen, M; Gideon, P

    1995-01-01

    Ultrasonography (US) of the knee in gonarthritis was evaluated with gadolinium-DTPA-enhanced MR imaging as a reference. The study included 13 patients with gonarthritis, 2 patients with osteoarthritis and 5 healthy controls. Compared to MR, US identified 100% (12/12) of joint effusions, 100% (5...

  7. Diagnostic Accuracy of Ultrasonography in the Initial Evaluation of Patients with Penetrating Chest Trauma

    Directory of Open Access Journals (Sweden)

    Farhad Heydari

    2014-03-01

    Full Text Available Introduction: Traumatic chest injuries (TCI are one of the most common causes of referring to the emergency departments, with high mortality and disability. This study was designed to evaluate the diagnostic accuracy of ultrasonography versus chest X ray (CXR in detection of hemo-pneumothorax for patients suffering penetrating TCI. Methods: The present cross-sectional study was performed to evaluate the diagnostic accuracy of ultrasonography in penetrating TCI victims referred to the emergency department of Shahid Kashani and Alzahra hospitals of Isfahan, Iran, from July 2012 to June 2013. Bedside ultrasonography and plain CXR was done on arrival and three hours after admission. The results of ultrasonography and radiography were separately evaluated by an emergency medicine specialist and a radiologist, who were blind to the aims of the study. Then, sensitivity, specificity, positive predictive value (PPV, negative predictive value (NPV, and kappa coefficient was considered to evaluate the accuracy of ultrasonography. Results: In this research 64 patients with penetrating chest trauma were assessed (98.4% male. The mean age of them was 25.6±8.5 years (rang: 13-65. The plain radiography revealed the eight (12.5 % cases of pneumothorax and one (1.6% hemothorax. The findings of primary ultrasonography also showed the same number of hemo-pneumothorax. Sensitivity and specificity of primary ultrasound in diagnosis of pneumothorax were 100% (95% Cl: 60.7- 100 and 100.0% (95% Cl, 92.0% to 100.0% and in detection of hemothorax were 100% (95% Cl: 50.5-100 and 100% (95% Cl: 92.8-100, respectively. Sensitivity and specificity of ultrasound in the third hour were 100% (95% Cl: 31.3-100 and 100% (95% Cl: 91.4-100, respectively. Conclusion: Findings of the present study have shown that ultrasonography has an acceptable diagnostic accuracy in the initial assessment of patients with penetrating chest trauma. However, because of its dependency on operator

  8. 29 CFR 1917.154 - Compressed air.

    Science.gov (United States)

    2010-07-01

    ... 29 Labor 7 2010-07-01 2010-07-01 false Compressed air. 1917.154 Section 1917.154 Labor Regulations...) MARINE TERMINALS Related Terminal Operations and Equipment § 1917.154 Compressed air. Employees shall be... this part during cleaning with compressed air. Compressed air used for cleaning shall not exceed a...

  9. Double-compression method for biomedical images

    Science.gov (United States)

    Antonenko, Yevhenii A.; Mustetsov, Timofey N.; Hamdi, Rami R.; Małecka-Massalska, Teresa; Orshubekov, Nurbek; DzierŻak, RóŻa; Uvaysova, Svetlana

    2017-08-01

    This paper describes a double compression method (DCM) of biomedical images. A comparison of image compression factors in size JPEG, PNG and developed DCM was carried out. The main purpose of the DCM - compression of medical images while maintaining the key points that carry diagnostic information. To estimate the minimum compression factor an analysis of the coding of random noise image is presented.

  10. Perceptual Image Compression in Telemedicine

    Science.gov (United States)

    Watson, Andrew B.; Ahumada, Albert J., Jr.; Eckstein, Miguel; Null, Cynthia H. (Technical Monitor)

    1996-01-01

    The next era of space exploration, especially the "Mission to Planet Earth" will generate immense quantities of image data. For example, the Earth Observing System (EOS) is expected to generate in excess of one terabyte/day. NASA confronts a major technical challenge in managing this great flow of imagery: in collection, pre-processing, transmission to earth, archiving, and distribution to scientists at remote locations. Expected requirements in most of these areas clearly exceed current technology. Part of the solution to this problem lies in efficient image compression techniques. For much of this imagery, the ultimate consumer is the human eye. In this case image compression should be designed to match the visual capacities of the human observer. We have developed three techniques for optimizing image compression for the human viewer. The first consists of a formula, developed jointly with IBM and based on psychophysical measurements, that computes a DCT quantization matrix for any specified combination of viewing distance, display resolution, and display brightness. This DCT quantization matrix is used in most recent standards for digital image compression (JPEG, MPEG, CCITT H.261). The second technique optimizes the DCT quantization matrix for each individual image, based on the contents of the image. This is accomplished by means of a model of visual sensitivity to compression artifacts. The third technique extends the first two techniques to the realm of wavelet compression. Together these two techniques will allow systematic perceptual optimization of image compression in NASA imaging systems. Many of the image management challenges faced by NASA are mirrored in the field of telemedicine. Here too there are severe demands for transmission and archiving of large image databases, and the imagery is ultimately used primarily by human observers, such as radiologists. In this presentation I will describe some of our preliminary explorations of the applications

  11. Evaluation of a new image compression technique

    International Nuclear Information System (INIS)

    Algra, P.R.; Kroon, H.M.; Noordveld, R.B.; DeValk, J.P.J.; Seeley, G.W.; Westerink, P.H.

    1988-01-01

    The authors present the evaluation of a new image compression technique, subband coding using vector quantization, on 44 CT examinations of the upper abdomen. Three independent radiologists reviewed the original images and compressed versions. The compression ratios used were 16:1 and 20:1. Receiver operating characteristic analysis showed no difference in the diagnostic contents between originals and their compressed versions. Subjective visibility of anatomic structures was equal. Except for a few 20:1 compressed images, the observers could not distinguish compressed versions from original images. They conclude that subband coding using vector quantization is a valuable method for data compression in CT scans of the abdomen

  12. The Efficacy of Magnetic Resonance Imaging and Color Doppler Ultrasonography in Diagnosis of Salivary Gland Tumors

    Directory of Open Access Journals (Sweden)

    Behrooz Davachi

    2014-12-01

    Full Text Available Background and aims. Although salivary gland tumors are not very common, early diagnosis and treatment is crucial because of their proximity to vital organs, and therefore, determining the efficacy of new imaging procedures becomes important. This study aimed to evaluate the efficacy of magnetic resonance imaging (MRI and color doppler ultrasonography parameters in the diagnosis and differentiation of benign and malignant salivary gland tumors. Materials and methods. In this cross-sectional study, color doppler ultrasonography and MRI were performed for 22 patients with salivary gland tumor. Demographic data as well as MRI, color doppler ultrasonography, and surgical parameters including tumor site, signal in MRI images, ultrasound echo, tumor border, lymphadenopathy, invasion, perfusion, vascular resistance index (RI, vascular pulse index (PI were analyzed using Chi-square test, Fisher’s exact test, and independent ttest. Results. The mean age of patients was 46.59±13.97 years (8 males and 14 females. Patients with malignant tumors were older (P < 0.01. The most common tumors were pleomorphic adenoma (36.4%, metastasis (36.4%, and mucoepidermoid carcinoma (9%. Nine tumors (40.9% were benign and 13 (59.1% were malignant. The overall accuracy of MRI and color doppler ultrasonography in determining tumor site was 100% and 95%, respectively. No significant difference observed between RI and PI and the diagnosis of tumor. Conclusion. Both MRI and ultrasonography have high accuracy in the localization of tumors. Well-identified border was a sign of benign tumors. Also, invasion to adjacent structures was a predictive factor for malignancy.

  13. Screening Performance Characteristic of Ultrasonography and Radiography in Detection of Pleural Effusion; a Meta-Analysis

    Directory of Open Access Journals (Sweden)

    Mahmoud Yousefifard

    2016-01-01

    Full Text Available Introduction: The role of ultrasonography in detection of pleural effusion has long been a subject of interest but controversial results have been reported. Accordingly, this study aims to conduct a systematic review of the available literature on diagnostic value of ultrasonography and radiography in detection of pleural effusion through a meta-analytic approach. Methods: An extended search was done in databases of Medline, EMBASE, ISI Web of Knowledge, Scopus, Cochrane Library, and ProQuest. Two reviewers independently extracted the data and assessed the quality of the articles. Meta-analysis was performed using a mixed-effects binary regression model. Finally, subgroup analysis was carried out in order to find the sources of heterogeneity between the included studies. Results: 12 studies were included in this meta-analysis (1554 subjects, 58.6% male. Pooled sensitivity of ultrasonography in detection of pleural effusion was 0.94 (95% CI: 0.88-0.97; I2= 84.23, p<0.001 and its pooled specificity was calculated to be 0.98 (95% CI: 0.92-1.0; I2= 88.65, p<0.001, while sensitivity and specificity of chest radiography were 0.51 (95% CI: 0.33-0.68; I2= 91.76, p<0.001 and 0.91 (95% CI: 0.68-0.98; I2= 92.86, p<0.001, respectively. Sensitivity of ultrasonography was found to be higher when the procedure was carried out by an intensivist or a radiologist using 5-10 MHz transducers. Conclusion: Chest ultrasonography, as a screening tool, has a higher diagnostic accuracy in identification of plural effusion compared to radiography. The sensitivity of this imaging modality was found to be higher when performed by a radiologist or an intensivist and using 5-10MHz probes.

  14. Anatomical features of plantar aponeurosis: cadaveric study using ultrasonography and magnetic resonance imaging

    Energy Technology Data Exchange (ETDEWEB)

    Moraes do Carmo, Clarissa Canella; Fonseca de Almeida Melao, Lina Isabel; Valle de Lemos Weber, Marcio Freitas; Trudell, Debra; Resnick, Donald [UCSD, Department of Radiology, San Diego, CA (United States); VA Healthcare System San Diego, La Jolla, CA (United States)

    2008-10-15

    Abnormalities of the plantar aponeurosis are commonly encountered in patients with subcalcaneal heel pain. Understanding normal anatomy is required to accurately diagnose some disorders of the foot. The purpose of our study was to describe the normal anatomy of the plantar aponeurosis, using ultrasonography and MRI with close anatomic correlation in cadavers. After MRI and ultrasonography of 10 cadaveric foot specimens, the thickness of the central and lateral portions of the plantar aponeurosis displayed by imaging studies was measured by three radiologists. One specimen was sectioned in the transverse plane, one in the coronal plane, one in the sagittal plane, and two in a sagittal oblique plane. Normal anatomy was identified and similar measurements of the plantar aponeurosis were also made. An average value was determined and a statistical analysis was accomplished. The calcaneal insertions of the plantar aponeurosis were better visualized than its distal portions with both MRI and ultrasonography. The measurements of the plantar aponeurosis made by three different radiologists were different, but without statistical significance. The average measurements for the central and lateral portions of the plantar aponeurosis with both imaging methods were different from each other because of differences in the morphology of these structures. The values obtained with ultrasonography and MRI, were also different from each other for both the central and lateral portions of the plantar aponeurosis, but with no statistical significance. We have described the detailed anatomy of the plantar aponeurosis with emphasis on the more distal structures that can be visualized with MRI. There was no statistically significant difference between the accuracy of ultrasonography and MRI regarding the measurements of the thickness of the central and lateral portions of the plantar aponeurosis. Knowledge of the normal anatomy of these structures enables the radiologist to identify early

  15. Reversible Causes in Cardiovascular Collapse at the Emergency Department Using Ultrasonography (REVIVE-US).

    Science.gov (United States)

    Chua, Mui Teng; Chan, Gene Wh; Kuan, Win Sen

    2017-08-01

    Ultrasonographic evaluation of patients in cardiac arrest is currently not protocolised in the advanced cardiac life support (ACLS) algorithm. Potentially reversible causes may be identified using bedside ultrasonography that is ubiquitous in most emergency departments (EDs). This study aimed to evaluate the incidence of sonographically detectable reversible causes of cardiac arrest by incorporating an ultrasonography protocol into the ACLS algorithm. Secondary objectives include rates of survival to hospital admission, hospital discharge, and 30-day mortality. We conducted a prospective study using bedside ultrasonography to evaluate for potentially reversible causes in patients with cardiac arrest at the ED of National University Hospital, Singapore, regardless of the initial electrocardiogram rhythm. A standardised ultrasonography protocol was performed during the 10-second pulse check window. Between June 2015 and April 2016, 104 patients were recruited, corresponding to 65% of all out-of-hospital cardiac arrest patients conveyed to the ED. Median age was 71 years (interquartile range, 55 to 80) and 71 (68.3%) patients were male. The most common rhythm on arrival was asystole (45.2%). Four (3.8%) patients had ultrasonographic findings suggestive of massive pulmonary embolism while 1 received intravenous thrombolysis and survived until discharge. Pericardial effusion without tamponade was detected in 4 (3.8%) patients and 6 (5.8%) patients had intra-abdominal free fluid. Twenty (19.2%) patients survived until admission, 2 of whom (1.9%) survived to discharge and beyond 30 days. Bedside ultrasonography can be safely incorporated into the ACLS protocol. Detection of any reversible causes may alter management and improve survival in selected patients.

  16. Accuracy of ultrasonography and magnetic resonance imaging in the diagnosis of placenta accreta.

    Directory of Open Access Journals (Sweden)

    Anne-Sophie Riteau

    Full Text Available PURPOSE: To evaluate the accuracy of ultrasonography and magnetic resonance imaging (MRI in the diagnosis of placenta accreta and to define the most relevant specific ultrasound and MRI features that may predict placental invasion. MATERIAL AND METHODS: This study was approved by the institutional review board of the French College of Obstetricians and Gynecologists. We retrospectively reviewed the medical records of all patients referred for suspected placenta accreta to two university hospitals from 01/2001 to 05/2012. Our study population included 42 pregnant women who had been investigated by both ultrasonography and MRI. Ultrasound images and MRI were blindly reassessed for each case by 2 raters in order to score features that predict abnormal placental invasion. RESULTS: Sensitivity in the diagnosis of placenta accreta was 100% with ultrasound and 76.9% for MRI (P = 0.03. Specificity was 37.5% with ultrasonography and 50% for MRI (P = 0.6. The features of greatest sensitivity on ultrasonography were intraplacental lacunae and loss of the normal retroplacental clear space. Increased vascularization in the uterine serosa-bladder wall interface and vascularization perpendicular to the uterine wall had the best positive predictive value (92%. At MRI, uterine bulging had the best positive predictive value (85% and its combination with the presence of dark intraplacental bands on T2-weighted images improved the predictive value to 90%. CONCLUSION: Ultrasound imaging is the mainstay of screening for placenta accreta. MRI appears to be complementary to ultrasonography, especially when there are few ultrasound signs.

  17. [The diagnostic value of ultrasonic elastography and ultrasonography comprehensive score in cervical lesions].

    Science.gov (United States)

    Lu, R; Xiao, Y

    2017-07-18

    Objective: To evaluate the clinical value of ultrasonic elastography and ultrasonography comprehensive scoring method in the diagnosis of cervical lesions. Methods: A total of 116 patients were selected from the Department of Gynecology of the first hospital affiliated with Central South University from March 2014 to September 2015.All of the lesions were preoperatively examined by Doppler Ultrasound and elastography.The elasticity score was determined by a 5-point scoring method. Calculation of the strain ratio was based on a comparison of the average strain measured in the lesion with the adjacent tissue of the same depth, size, and shape.All these ultrasonic parameters were quantified, added, and arrived at ultrasonography comprehensive scores.To use surgical pathology as the gold standard, the sensitivity, specificity, accuracy of Doppler Ultrasound, elasticity score and strain ratio methods and ultrasonography comprehensive scoring method were comparatively analyzed. Results: (1) The sensitivity, specificity, and accuracy of Doppler Ultrasound in diagnosing cervical lesions were 82.89% (63/76), 85.0% (34/40), and 83.62% (97/116), respectively.(2) The sensitivity, specificity, and accuracy of the elasticity score method were 77.63% (59/76), 82.5% (33/40), and 79.31% (92/116), respectively; the sensitivity, specificity, and accuracy of the strain ratio measure method were 84.21% (64/76), 87.5% (35/40), and 85.34% (99/116), respectively.(3) The sensitivity, specificity, and accuracy of ultrasonography comprehensive scoring method were 90.79% (69/76), 92.5% (37/40), and 91.38% (106/116), respectively. Conclusion: (1) It was obvious that ultrasonic elastography had certain diagnostic value in cervical lesions. Strain ratio measurement can be more objective than elasticity score method.(2) The combined application of ultrasonography comprehensive scoring method, ultrasonic elastography and conventional sonography was more accurate than single parameter.

  18. Cost-effectiveness analysis of ultrasonography screening for nonalcoholic fatty liver disease in metabolic syndrome patients

    Science.gov (United States)

    Phisalprapa, Pochamana; Supakankunti, Siripen; Charatcharoenwitthaya, Phunchai; Apisarnthanarak, Piyaporn; Charoensak, Aphinya; Washirasaksiri, Chaiwat; Srivanichakorn, Weerachai; Chaiyakunapruk, Nathorn

    2017-01-01

    Abstract Background: Nonalcoholic fatty liver disease (NAFLD) can be diagnosed early by noninvasive ultrasonography; however, the cost-effectiveness of ultrasonography screening with intensive weight reduction program in metabolic syndrome patients is not clear. This study aims to estimate economic and clinical outcomes of ultrasonography in Thailand. Methods: Cost-effectiveness analysis used decision tree and Markov models to estimate lifetime costs and health benefits from societal perspective, based on a cohort of 509 metabolic syndrome patients in Thailand. Data were obtained from published literatures and Thai database. Results were reported as incremental cost-effectiveness ratios (ICERs) in 2014 US dollars (USD) per quality-adjusted life year (QALY) gained with discount rate of 3%. Sensitivity analyses were performed to assess the influence of parameter uncertainty on the results. Results: The ICER of ultrasonography screening of 50-year-old metabolic syndrome patients with intensive weight reduction program was 958 USD/QALY gained when compared with no screening. The probability of being cost-effective was 67% using willingness-to-pay threshold in Thailand (4848 USD/QALY gained). Screening before 45 years was cost saving while screening at 45 to 64 years was cost-effective. Conclusions: For patients with metabolic syndromes, ultrasonography screening for NAFLD with intensive weight reduction program is a cost-effective program in Thailand. Study can be used as part of evidence-informed decision making. Translational Impacts: Findings could contribute to changes of NAFLD diagnosis practice in settings where economic evidence is used as part of decision-making process. Furthermore, study design, model structure, and input parameters could also be used for future research addressing similar questions. PMID:28445256

  19. Spinal cord compression secondary to extramedullary hematopoiesis in a dog.

    Science.gov (United States)

    Williams, Lindsay M; Skeen, Todd M

    2013-03-15

    An 11-year-old spayed female Siberian Husky was evaluated because of a 2-week history of progressive paraparesis. Results of neurologic examination were consistent with a T3-L3 myelopathy. There were no abnormalities on CBC, and hypercalcemia was noted on serum biochemical analysis. Several hypoechoic splenic nodules were evident on abdominal ultrasonography, and results of fine-needle aspiration cytology were consistent with splenic extramedullary hematopoiesis (EMH). Two compressive, extradural masses in the dorsal epidural space of the thoracolumbar region of the spinal cord were seen on MRI images. A dorsal laminectomy was performed to remove the extradural spinal masses. Results of histologic examination of tissue samples were consistent with EMH. Following surgery, clinical signs of paraparesis resolved, and there was no recurrence of the masses 24 months after surgery. Extramedullary hematopoesis should be considered as a differential diagnosis in dogs in which results of diagnostic imaging indicate a epidural mass. In human patients, spinal EMH usually occurs secondary to an underlying hematologic disease, but it can also occur spontaneously. Treatment options reported for humans include surgical decompression, radiation therapy, chemotherapy, and blood transfusion. The dog of this report responded favorably to surgical decompression and was clinically normal 2 years after surgery.

  20. Evaluation of compression ratio using JPEG 2000 on diagnostic images in dentistry

    International Nuclear Information System (INIS)

    Jung, Gi Hun; Han, Won Jeong; Yoo, Dong Soo; Kim, Eun Kyung; Choi, Soon Chul

    2005-01-01

    To find out the proper compression ratios without degrading image quality and affecting lesion detectability on diagnostic images used in dentistry compressed with JPEG 2000 algorithm. Sixty Digora peri apical images, sixty panoramic computed radiographic (CR) images, sixty computed tomography (CT) images, and sixty magnetic resonance (MR) images were compressed into JPEG 2000 with ratios of 10 levels from 5:1 to 50:1. To evaluate the lesion detectability, the images were graded with 5 levels (1 : definitely absent ; 2 : probably absent ; 3 : equivocal ; 4 : probably present ; 5 : definitely present), and then receiver operating characteristic analysis was performed using the original image as a gold standard. Also to evaluate subjectively the image quality, the images were graded with 5 levels (1 : definitely unacceptable ; 2 : probably unacceptable ; 3 : equivocal ; 4 : probably acceptable ; 5 : definitely acceptable), and then paired t-test was performed. In Digora, CR panoramic and CT images, compressed images up to ratios of 15:1 showed nearly the same lesion detectability as original images, and in MR images, compressed images did up to ratios of 25:1. In Digora and CR panoramic images, compressed images up to ratios of 5:1 showed little difference between the original and reconstructed images in subjective assessment of image quality. In CT images, compressed images did up to ratios of 10:1 and in MR images up to ratios of 15:1. We considered compression ratios up to 5:1 in Digora and CR panoramic images, up to 10:1 in CT images, up to 15:1 in MR images as clinically applicable compression ratios.